diff --git a/.gitattributes b/.gitattributes index 6aed1557cc1ef643884ca76a689a3ddb74b2d408..24fd8df80750f7dcebbfefc0490e631f84ef3fe5 100644 --- a/.gitattributes +++ b/.gitattributes @@ -271,3 +271,91 @@ original/WG8/O-RAN.WG8.TS.AAD.0-R005-v17.00.docx filter=lfs diff=lfs merge=lfs - original/WG9/O-RAN.WG9.TS.ARCH-REQ-RAN-FH-CPTN[[:space:]].X-R005-v01.00.pdf filter=lfs diff=lfs merge=lfs -text original/WG9/O-RAN.WG9.XPSAAS.0-R005-v10.00.pdf filter=lfs diff=lfs merge=lfs -text original/WG9/O-RAN.WG9.XTRP-REQ.0-R005-v02.00.pdf filter=lfs diff=lfs merge=lfs -text +original/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/SuFG/O-RAN.SuFG.CE-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00.pdf filter=lfs diff=lfs merge=lfs -text +original/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN.WG1.Information[[:space:]]Model[[:space:]]and[[:space:]]Data[[:space:]]Models-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN.WG1.O1-Interface.0-v04.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN.WG1.OAM-Architecture-v04.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG2/O-RAN.WG2.AIML-v01.03.pdf filter=lfs diff=lfs merge=lfs -text +original/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01.pdf filter=lfs diff=lfs merge=lfs -text +original/WG2/O-RAN.WG2.R1TP-v04.02.docx filter=lfs diff=lfs merge=lfs -text +original/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04.docx filter=lfs diff=lfs merge=lfs -text +original/WG3/O-RAN.WG3.E2TS-R003-v02.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG3/ORAN-WG3.E2SM-NI-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG5/O-RAN.WG5.Transport.0-v01.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG5/O-RAN.WG5.U.0-R003-v07.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.AAL[[:space:]]FEC.R004-v04.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01.pdf filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.ASD-R003-v01.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.CADS-v08.01.pdf filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.CLOUD-REF-v02.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.O-Cloud[[:space:]]Notification[[:space:]]API-v04.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.O-Cloud-ES-v02.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.O2-GAnP-v01.02.pdf filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.DSC.0-v04.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.IPC-HAR.0-v03.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.IPC-TEST.0-v01.docx filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.NES.0-R003-v02.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG7/O-RAN.WG7.OMC-HAR.0-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG8/O-RAN.WG8.IOT.0-R004-v12.00.docx filter=lfs diff=lfs merge=lfs -text +original/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG9/O-RAN.WG9.XTRP-REQ-v01.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00.pdf filter=lfs diff=lfs merge=lfs -text +original/WG9/ORAN-WG9.WDM.0-R004-v05.00.pdf filter=lfs diff=lfs merge=lfs -text diff --git a/STATUS.md b/STATUS.md index ecb331ed509fb7b480b45d1d3dbe35c72819498c..e5f462c48737129a52c51a02e9f3fb73b6a613a6 100644 --- a/STATUS.md +++ b/STATUS.md @@ -2,6 +2,6 @@ State: complete mirror -- Original files: 140 -- Marked documents: 80 +- Original files: 229 +- Marked documents: 170 - Missing marked documents: 0 diff --git a/manifest.jsonl b/manifest.jsonl index 27e788b6c10d6660f5305996f71a03906067e6fb..0465e582ca2424dd55fd388c48fee8374a832151 100644 --- a/manifest.jsonl +++ b/manifest.jsonl @@ -138,3 +138,92 @@ {"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG9/O-RAN.WG9.TS.ARCH-REQ-RAN-FH-CPTN .X-R005-v01.00/raw.md", "normalized_path": "original/WG9/O-RAN.WG9.TS.ARCH-REQ-RAN-FH-CPTN .X-R005-v01.00.pdf", "original_path": "WG9/O-RAN.WG9.TS.ARCH-REQ-RAN-FH-CPTN .X-R005-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "cdcd99b19b331d2f8c0bbfcd98adf3b33859b27f6ca055ad86631c22131e5151"} {"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG9/O-RAN.WG9.XPSAAS.0-R005-v10.00/raw.md", "normalized_path": "original/WG9/O-RAN.WG9.XPSAAS.0-R005-v10.00.pdf", "original_path": "WG9/O-RAN.WG9.XPSAAS.0-R005-v10.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "17fe9e76fcee8460784e7347334b2430574a55d2f64c1ecca838c4200dd9bf45"} {"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG9/O-RAN.WG9.XTRP-REQ.0-R005-v02.00/raw.md", "normalized_path": "original/WG9/O-RAN.WG9.XTRP-REQ.0-R005-v02.00.pdf", "original_path": "WG9/O-RAN.WG9.XTRP-REQ.0-R005-v02.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "3752eef2abd845a6be763a218b69162a524d257ca0ccf76fe9e3ac543ae67f2e"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/raw.md", "normalized_path": "original/WG1/O-RAN.WG1.Information Model and Data Models-v01.00.pdf", "original_path": "WG1/O-RAN.WG1.Information Model and Data Models-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "eca6a3ecf1f34501b1ffa6feb1c7f02db03982c3b0d343c0a758911cb0c42b93"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/raw.md", "normalized_path": "original/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00.pdf", "original_path": "TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "d605211c8ee1f345db812d3e052ec53b0e137d7c8b8c8f9c37c1d4d2a6c2e592"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/SuFG/O-RAN.SuFG.CE-v01.00/raw.md", "normalized_path": "original/SuFG/O-RAN.SuFG.CE-v01.00.pdf", "original_path": "SuFG/O-RAN.SuFG.CE-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "b7528ac4539bd4beeef359e60ee97aef9366afaad16c769984565510569e80ce"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/raw.md", "normalized_path": "original/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00.pdf", "original_path": "WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "dd74c19a3a8c9eea64500682af7a572da31fd5c51830bdcf5e356fee5665c7fe"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/raw.md", "normalized_path": "original/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00.pdf", "original_path": "SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "41b4e4d600c88bb2e662eb8daf4cbd6a1e2942b5e26b9aaaeeeca55dcc228202"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/raw.md", "normalized_path": "original/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00.pdf", "original_path": "WG1/O-RAN-WG1-CCIN-TR-R004-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "e1310961f80c5d21ef4a2e4a0acac2c9e63ac630172ec0eff0b05e66e00bc1f0"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/raw.md", "normalized_path": "original/WG1/O-RAN.WG1.OAM-Architecture-v04.00.pdf", "original_path": "WG1/O-RAN.WG1.OAM-Architecture-v04.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "355d24fa8c105ad1950ba3f457db646e02028305f8ff05b8e716db2ec4cefa7e"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/raw.md", "normalized_path": "original/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00.docx", "original_path": "WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "3af0d214ff8dd6ab599c1791098ea97af47c1e5d04f8ef6564f6b04596996fda"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/raw.md", "normalized_path": "original/WG1/O-RAN.WG1.O1-Interface.0-v04.00.pdf", "original_path": "WG1/O-RAN.WG1.O1-Interface.0-v04.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "e56216c86b396d4c44c3a600f2facf0862b7c706a6b0464824d95f092197a7c2"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/raw.md", "normalized_path": "original/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00.pdf", "original_path": "WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "c5ba3f9b6b6714e1a11fe43331d5e2a79dc235fb56ef6c294d0139606cc8f206"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/raw.md", "normalized_path": "original/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00.docx", "original_path": "WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "bdfaffe1d62d639bfd999a8793d5e50dce6822aa5e2cf62cf6e9753e1327d08c"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/raw.md", "normalized_path": "original/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00.docx", "original_path": "WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "b0285e65fad88e4311bf186247b757ef314884583cb6dd3f721298534a9c92b0"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/raw.md", "normalized_path": "original/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00.pdf", "original_path": "TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "bffc70106a976b4a09d432772a122b18362f2a03cf0c50ef8f4cae5acfae7bbf"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/raw.md", "normalized_path": "original/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00.pdf", "original_path": "WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "accc7c58fa5070d2f7326ef9b0ed71a8e4bf80f97c9867a92bc88b59cdbc58cf"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/raw.md", "normalized_path": "original/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00.pdf", "original_path": "WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "821cf468aa81aa0a3170db6003127a148767793e65dd8fa7b10a6b4ad81bf00c"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/raw.md", "normalized_path": "original/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00.pdf", "original_path": "WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "a062d4ce0974781a819be6bf347762fa3d1ee368c50ce2d492065e7bf0515da9"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/raw.md", "normalized_path": "original/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00.docx", "original_path": "WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "5609c8a40f0d12bf6c554a5fea49f0159c7d3560c6d55678474b71731773585d"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00.docx", "original_path": "WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "3eda2f9bbaaee413926dfecbbbd294489f176ceff7f8ad3ae153c0ee3ce12eab"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00.docx", "original_path": "WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "9f55f030a98ed4f88d7b96552d388cc8bb28b2c0c76445b0a45e87394793aa17"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00.docx", "original_path": "WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "5d3d4693a904bc47fa5268456ae19ca4b6b70d2102229dfd5ff2fd5b2ad33fe6"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00.docx", "original_path": "WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "0031175d6eed1efdc73886b5f49478e9e50401dbdefadc08092781e5092fb4b8"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/raw.md", "normalized_path": "original/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00.pdf", "original_path": "WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "042ac1000d6031ab80758e62902e723e7c2c6f21d2e7b51954e2a44e6c19831e"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/raw.md", "normalized_path": "original/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00.pdf", "original_path": "WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "29ec376fc9fc4992f93107c9172873eed4236e4f022b944a46c2e40eaf39a0a2"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00.docx", "original_path": "WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "b527e25202264851de2f2fb680fd27de35d695feda7ec6edd8bd5de3a6e11f72"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00.docx", "original_path": "WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "67f5af4b48ae03d550dd72ae6461fb9dcc2a10ac3e87c9040d1ef562af0913aa"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00.docx", "original_path": "WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "f9b1398169c15cec27d92c5316cadada784ea03ea4a5536215b38bce89a839a0"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00.docx", "original_path": "WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "6533556b7bd530b9ddd40b9d4fd9fc83768bfe46c08cb2380970fd621115b198"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00.docx", "original_path": "WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "a52e8b1892429a6bca4d06d6b26e244bc184fdb1f2fe91de4358012909b9239e"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00.docx", "original_path": "WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "a78561e0859782bc217b00b2356ec944c79ea782974857b4d628caeac95b8343"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG2/O-RAN.WG2.R1TP-v04.02/raw.md", "normalized_path": "original/WG2/O-RAN.WG2.R1TP-v04.02.docx", "original_path": "WG2/O-RAN.WG2.R1TP-v04.02.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "84f23dfb6f143926e416622ab7e3ac3e55bfc162bdc65b99af66da7246dbc2a4"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/raw.md", "normalized_path": "original/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04.docx", "original_path": "WG2/O-RAN.WG2.TS.A1TP-R004-v03.04.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "b40117b8c69c774f65694e0894690bedb6c1b23c334ad66c8c22b174418aa750"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/raw.md", "normalized_path": "original/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01.pdf", "original_path": "WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "366cb05674d3104148c4e2a83610bb441d6a38dfc97dadf76c0b23d8db915f8f"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG2/O-RAN.WG2.AIML-v01.03/raw.md", "normalized_path": "original/WG2/O-RAN.WG2.AIML-v01.03.pdf", "original_path": "WG2/O-RAN.WG2.AIML-v01.03.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "afd260f0360d91e64516f637c17bdd25f24ec5594fe67429a48b5ffd69e4611c"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/raw.md", "normalized_path": "original/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00.docx", "original_path": "WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "37f5a26a106959e9ef264208d46972f08349132e39137e3e2fecf30d376bf71b"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/raw.md", "normalized_path": "original/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00.docx", "original_path": "WG3/O-RAN.WG3.TR.ConMit-R004-v01.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "bade55c3789c24f108f393f3dbbef2341cb46e67e5327e93060f99a727588e94"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/raw.md", "normalized_path": "original/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00.pdf", "original_path": "WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "9b28f7730c4f80d854bb2461d8df8d7f4716a24255281e845c366fc382b6b9e8"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/raw.md", "normalized_path": "original/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00.pdf", "original_path": "WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "b917d19e4dfbf6d5efca202012468f1b55b490937fb20b2f01f87a0953f37790"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/raw.md", "normalized_path": "original/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00.pdf", "original_path": "WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "950b9296382cbcbbb6b93bc1c34429ea8a10526174bb2e6afef4cbbdb4ba1946"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/raw.md", "normalized_path": "original/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00.pdf", "original_path": "WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "743bcbad23ecf20c7c6f2f31c1ede85b79688e6ff51eddf432b331a04852cc16"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/raw.md", "normalized_path": "original/WG3/O-RAN.WG3.E2TS-R003-v02.00.docx", "original_path": "WG3/O-RAN.WG3.E2TS-R003-v02.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "c7b25fb7d7f0269f03a75762c58d25316fb1384fb1e81f6f9b5dc274ddadf950"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/raw.md", "normalized_path": "original/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00.pdf", "original_path": "WG3/O-RAN.WG3.TS.E2SM-R004-v07.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "356eb9c84a4b11032051ad402659bc29c883b3a3267fec68b3559f6771de47e6"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00.docx", "original_path": "WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "04435d0c9a9d3e57bd7af4a0e35ebf0657636239227565c1cbb94af7d0721c44"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00.docx", "original_path": "WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "76c9177987feebc9a5305a8b3e9da54d5a69d2604d1615c2e425113b85777a9f"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/raw.md", "normalized_path": "original/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00.pdf", "original_path": "WG3/O-RAN.WG3.TS.E2AP-R004-v07.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "5393fd8ae38bd3999473669ef3aba8d010157f044476ed275efe956c90d4f2ac"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/raw.md", "normalized_path": "original/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00.docx", "original_path": "WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "2bad8afd31bdfb02b821007996a52de1e24108af5b7a47657950c5a6441c8c4a"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG5/O-RAN.WG5.Transport.0-v01.00/raw.md", "normalized_path": "original/WG5/O-RAN.WG5.Transport.0-v01.00.docx", "original_path": "WG5/O-RAN.WG5.Transport.0-v01.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "9a87fa76d6536fe726eb1eb24ac0cc73c52d60708c33df1536e30628c16196c5"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG5/O-RAN.WG5.U.0-R003-v07.00/raw.md", "normalized_path": "original/WG5/O-RAN.WG5.U.0-R003-v07.00.docx", "original_path": "WG5/O-RAN.WG5.U.0-R003-v07.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "2211fac297e198afb1cfcb95e6392b42d9d88d61b22f1ea67bbf5ae0a626767a"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/raw.md", "normalized_path": "original/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00.pdf", "original_path": "WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "9c108c795dc448880b5905878ed4618b205017c9ca5b1e013733d25ad6415253"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.AAL FEC.R004-v04.00.docx", "original_path": "WG6/O-RAN.WG6.AAL FEC.R004-v04.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "ff7ab08dcfbb2bbfdd2f7b9fb3cb82da860f4f7c707e064ceb9f15c266ece98f"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/raw.md", "normalized_path": "original/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00.pdf", "original_path": "WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "802f2868e5a515ec085542477e53c82b23538ec5567b3cf3b26cac39ed25f7ae"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01.pdf", "original_path": "WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "54235c70ad3969df02226a7b632ba2f49e6b5658aba56209440c62789b45c62e"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/raw.md", "normalized_path": "original/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00.pdf", "original_path": "WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "b760bcdfb863171c1cd88dbe021a911328a9a9fd420ef06f6ac04be330ca787e"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00.pdf", "original_path": "WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "090330c278bf4400f2cff7743b25e7161f70a1c99f0d5b4a4d072b20d6f36048"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG6/O-RAN.WG6.ASD-R003-v01.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.ASD-R003-v01.00.docx", "original_path": "WG6/O-RAN.WG6.ASD-R003-v01.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "09e9e9f0e75fd15924ec0acda441304cf47ac9da146a9fdcb30b69a85fd879cc"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/raw.md", "normalized_path": "original/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00.pdf", "original_path": "WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "ab8fffc95cc878329133f5eea4a00520fe7b643327f33add5aae4fba62bd49ed"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00.pdf", "original_path": "WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "ced86ef8813d6d5e86848f561af1e13b98f5341e577d122b73b803b19c5804aa"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00.pdf", "original_path": "WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "e08ae35486f62d0b2dd74b87fd6e733bb48f0826755d1ebccb9be9743100bcf6"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00.docx", "original_path": "WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "f3b518bb23d8bddfa7303e66f5658da8e2c347f514a335c029e513c296a83c8f"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.O2-GAnP-v01.02.pdf", "original_path": "WG6/O-RAN.WG6.O2-GAnP-v01.02.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "713f3370a2b05ec2b0ac7c665672095ef594596888e7c186b402fb0b0e4f480c"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.O-Cloud-ES-v02.00.pdf", "original_path": "WG6/O-RAN.WG6.O-Cloud-ES-v02.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "be84efe2ede6ce12dcf3324f9ca5de810b53570aa237fb1a4c33209840e39a8a"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00.docx", "original_path": "WG6/O-RAN.WG6.O-Cloud Notification API-v04.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "ba8b2c0c78ca4ff646de1e0d54c3452bec6aabbd1bfba05ef4896e1bda70d6c7"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/raw.md", "normalized_path": "original/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00.pdf", "original_path": "WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "ffd8b69f954152a3d92a0dfb6ed1d029b6cde0711a90ade4c885adf276d78adf"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.CLOUD-REF-v02.00.pdf", "original_path": "WG6/O-RAN.WG6.CLOUD-REF-v02.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "2d866f86e5e3a5f66211995a7274475aa2b81f57c95b8e7851a32c79c3121826"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN.WG6.CADS-v08.01/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.CADS-v08.01.pdf", "original_path": "WG6/O-RAN.WG6.CADS-v08.01.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "e94cd5bf1cb98420bd9899c863c8875744f197f4ad9a0f728f4014170d47f57f"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00.docx", "original_path": "WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "2a64c20b788444340df053e67f12973014d3434319a2ab78f046cfeefb31d8cd"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.DSC.0-v04.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.DSC.0-v04.00.pdf", "original_path": "WG7/O-RAN.WG7.DSC.0-v04.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "9fe1cd2120c05b3f9492733f8374f4d4a976f69c06870c5677ee462f30353e15"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/raw.md", "normalized_path": "original/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00.pdf", "original_path": "WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "cefaf25a5e01606cef1ad16bac934218fbadbcfa371b10033a011ae2acb24e48"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00.pdf", "original_path": "WG7/O-RAN.WG7.FHGW-HRD.0-v02.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "76f4e742bf4d832ce1c9e1a832795742c93b91f967294c0bb21eea7565681688"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.IPC-HAR.0-v03.00.pdf", "original_path": "WG7/O-RAN.WG7.IPC-HAR.0-v03.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "841ea58c835dc1a20e3fda2598987a149d535f2a6fa3b094902a25d763370248"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01.pdf", "original_path": "WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "cf45238aed538d0f7d9bb3b35bbd1d7dfe05329fa7411a2669a4a724a621438b"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/raw.md", "normalized_path": "original/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00.pdf", "original_path": "WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "56e85081f7282d916e822ac69feefbb96e25845be6102bae950dbb9a6b6ced23"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00.pdf", "original_path": "WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "62c6c9f515c3764ffd7c905c598ee1873949bd6b02e4a8a286d10e478025bbb0"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.NES.0-R003-v02.00.pdf", "original_path": "WG7/O-RAN.WG7.NES.0-R003-v02.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "b42f07afcbced219d64d3c7a7496063a10d49d43cab41ec7e7e84aab235c1de7"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.IPC-TEST.0-v01.docx", "original_path": "WG7/O-RAN.WG7.IPC-TEST.0-v01.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "d25fb773649cf3b21dac84dfa51b9b7e63fcc0ab417f0032ab58fc3b802efbfc"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00.pdf", "original_path": "WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "d9eeced166f401dbbefb757e1b87651e13c715261d681009c8a4d6ee0ae428e7"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.OMC-HAR.0-v01.00.pdf", "original_path": "WG7/O-RAN.WG7.OMC-HAR.0-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "2e8e9c983e097db97fab48dbedc32db2f006ccddbad820b63fd41147f8935222"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00.pdf", "original_path": "WG7/O-RAN.WG7.OMAC-HAR.0-v05.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "78ffc4476839dd0ecda54f1c1c8bf29db073fda34d1f7b5419193219f40129b8"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00.pdf", "original_path": "WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "ec5482e51b98d940764ea8243de97f405fcb0f35f4d7d25801f8dd244763bb41"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00.pdf", "original_path": "WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "b37f100898bfb7f40f0bdebb987c81d9a9ddc42581d65ccff9d869ed83bceba4"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG3/ORAN-WG3.E2SM-NI-v01.00/raw.md", "normalized_path": "original/WG3/ORAN-WG3.E2SM-NI-v01.00.pdf", "original_path": "WG3/ORAN-WG3.E2SM-NI-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "1f5e1012fb2d434e2088c54f5ec04d9bfc3c783f8476db913b8dfd7053fc5dfe"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/raw.md", "normalized_path": "original/WG9/O-RAN.WG9.XTRP-REQ-v01.00.pdf", "original_path": "WG9/O-RAN.WG9.XTRP-REQ-v01.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "5fb7291d88b92c1f554fd720d7b28fa6e0458f2feae9eb6c2248ffdc441a648b"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/raw.md", "normalized_path": "original/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00.docx", "original_path": "WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "a8d98799bcff1b923aea0d8a0fb3855f42ae4d0ae66181f8ba6afd9256bb7195"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/raw.md", "normalized_path": "original/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00.docx", "original_path": "WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "7bece6f5f7b092cb31663c7d62d09e4e2ce574fe578f6a2fd6a70969b1f1dc32"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/raw.md", "normalized_path": "original/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00.pdf", "original_path": "WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "081806fa7e36a58dc6bfed233e59c31414e1c16f8ac190a01bafd6ba7edfd114"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/raw.md", "normalized_path": "original/WG9/ORAN-WG9.WDM.0-R004-v05.00.pdf", "original_path": "WG9/ORAN-WG9.WDM.0-R004-v05.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "61ea3061689f7a39cd281e6d2c9e987d4d6a9c937d9b9d4a9a575fe78361b2ef"} +{"body": "oran", "file_type": ".docx", "marked_path": "marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/raw.md", "normalized_path": "original/WG8/O-RAN.WG8.IOT.0-R004-v12.00.docx", "original_path": "WG8/O-RAN.WG8.IOT.0-R004-v12.00.docx", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "98b6a42a0cdf86b628555df316215875cde0870719f902f0e8a95ec5fdc2d56e"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/raw.md", "normalized_path": "original/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00.pdf", "original_path": "WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "5867d6330eadc4c90f94b922e710e7df951361b93c5217e8b38e5c2f76317c0d"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/raw.md", "normalized_path": "original/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00.pdf", "original_path": "WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "5c62d41e7a6dc7c1e32e8a3956b52392855a7b1ffea58728ea61bf0cc373f33b"} +{"body": "oran", "file_type": ".pdf", "marked_path": "marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/raw.md", "normalized_path": "original/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00.pdf", "original_path": "WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00.pdf", "parse_status": "OK", "reason": "parsed", "section": "original", "sha256": "3af9137f21dcdcc5cf9f0335265b1aa04aaad4669607bae3cd97c481b827607e"} diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/010e48ed510b325e276784a7b0999d1b_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/010e48ed510b325e276784a7b0999d1b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..79e50e38cb0f0446334479621e3fbc388a511074 --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/010e48ed510b325e276784a7b0999d1b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8f8b9039b416b9a2337615b867536dc76cdfb8136a2931c0a3a67c29137a4e92 +size 4081 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/209662cf0970dfb0ce0dc34ee71992db_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/209662cf0970dfb0ce0dc34ee71992db_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..91897498a8ae790648986c7d7fe4a88fc3242b6c --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/209662cf0970dfb0ce0dc34ee71992db_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bf7e98979fbfd3cfd6f30118b7091081173f3bde1236e2aa6a2fcb269c32f61a +size 4008 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/3c839b11237b9712cbdae787e346480f_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/3c839b11237b9712cbdae787e346480f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9a6f8954d712cc7f647598a1b7ee839becd13d58 --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/3c839b11237b9712cbdae787e346480f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e2db1b01ecb95b799dc5382b3a5ea9d460c18e3de856a7ac553d8bda33b2f9a3 +size 4046 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/4e8fd59a34a4a31db76f32d4166691ad_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/4e8fd59a34a4a31db76f32d4166691ad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9d52578621d33b131755541f7ccb6e0a5c7f743b --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/4e8fd59a34a4a31db76f32d4166691ad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2e7decbbfa40fbdd65b8342b3adda77b3f2a012241332a00dc58027f6c7e8186 +size 4137 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/522509beecf2137e2396740220972b9d_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/522509beecf2137e2396740220972b9d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..55a19ff6996e3fb673d944497e1afcd0a413002a --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/522509beecf2137e2396740220972b9d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a358e50eaf81ef93862d2710bf195cc21c4677cee7dd659a2af399b9c41d1fc2 +size 4138 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/61d923937ec1e9aa742f0a035a3c5603_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/61d923937ec1e9aa742f0a035a3c5603_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..90cde02daf11fc6af0c5539701473bff0067d3d2 --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/61d923937ec1e9aa742f0a035a3c5603_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8a9f830523bd10018e9980af1c7e46a1402a19d9882ad08e2527a77c73f69ea6 +size 116795 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/6296a7bfcbd7261adaa5717928797d2f_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/6296a7bfcbd7261adaa5717928797d2f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f23bec0f1b26f35941cf64498faace907dfb7f36 --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/6296a7bfcbd7261adaa5717928797d2f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:113c5c31cca5c06c1ba7b1312bd7e99ff96cdb0a5d4e6d6a43e2a9f4f62e8f00 +size 3966 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/75f60cca7dbb0e8b244d0195e79a4cd8_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/75f60cca7dbb0e8b244d0195e79a4cd8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a51962c010ca3a9daad1e9887801bfe4cb8b69b7 --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/75f60cca7dbb0e8b244d0195e79a4cd8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0437399ec5c96e52256cc283949de54f14a2767f9ce55b56e1a69eed6dcd2f9f +size 4124 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/797e4a5f8ada5decbdfd3583537bf47c_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/797e4a5f8ada5decbdfd3583537bf47c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7aba8c5a5c238c3a19885b3db28d8642b42d85c1 --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/797e4a5f8ada5decbdfd3583537bf47c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a862a22732cc1f56c552089499fc0e2acb0f887b2110efc207b9580365f94f86 +size 4098 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/84e1e63b6b13269ee4801e88cc6e6e1e_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/84e1e63b6b13269ee4801e88cc6e6e1e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aaa592564db15659bb64d75bc469a12935ff2c1c --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/84e1e63b6b13269ee4801e88cc6e6e1e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e91ad6d83d219d3ef62981ecff4c1eef8dc285320b6f581c10b9380569bca7a3 +size 12640 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/9a4ae61a0ccbc8f9b4e00c83bbf4fbbf_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/9a4ae61a0ccbc8f9b4e00c83bbf4fbbf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..19cdf296840e7a7a00d747a7b5eae82b47f2d5c5 --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/9a4ae61a0ccbc8f9b4e00c83bbf4fbbf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6b5a227c9db66163f0f09d257ad5f1095260230fa51274eba05fa0a3c8d9b6e9 +size 4118 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/b5bb259847073c5fd0f9a6b4a4504b67_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/b5bb259847073c5fd0f9a6b4a4504b67_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8ef7ac75cf6ba9097213051e6265e8fd534967ae --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/b5bb259847073c5fd0f9a6b4a4504b67_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:997643ce4774df4fe0717961009e72888dd54e9f87c8841a931ca6ed6ba5f2b5 +size 4069 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/c1f7c56b5f3af25908eafcf6bf61ac60_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/c1f7c56b5f3af25908eafcf6bf61ac60_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6d690a3f5a9ea438829d0d54fbcd9923f698611a --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/c1f7c56b5f3af25908eafcf6bf61ac60_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:74b357ef0660c86835d17dbd85c28ab8f622f778e3d5fc252948c20ab2e99f90 +size 4108 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/cdce772dd95ccd6159eae2e11d7f3d7d_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/cdce772dd95ccd6159eae2e11d7f3d7d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..16a7e5268aacfc18c649235c1199ab6d6c950cd3 --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/cdce772dd95ccd6159eae2e11d7f3d7d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7be447948391c53cce76b096508eb6aef7f6ef595b3361d6b2e2a29e713e673d +size 4135 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/d202a27bd66369d201fb78c18d384c6a_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/d202a27bd66369d201fb78c18d384c6a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ece690e36ae5b21dcbf7ee9832f54b9d6dec42d3 --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/d202a27bd66369d201fb78c18d384c6a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6cdee9f75be9cbcc8fdc01026af8ba54f00732f56db95079dcd84c73bcff4199 +size 4111 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/e340ceb30bfe94a5de1e448c2a517ae4_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/e340ceb30bfe94a5de1e448c2a517ae4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5feb04567feddc71c87508033436888f6b588612 --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/e340ceb30bfe94a5de1e448c2a517ae4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6075558c0f5da83ac6a3cdddbda76a76628c8316a36a9cf063646309903774d0 +size 4112 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/f08e39ce885c620da4ea2847d9bd0190_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/f08e39ce885c620da4ea2847d9bd0190_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1c272f6864d08fb731b12a456cd71a0b77867b2f --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/f08e39ce885c620da4ea2847d9bd0190_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8ffde242f7a10242ac0da1fd0cdfe086e329130fb39f2b36e4c9acfb1e47a0db +size 4005 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/fcdffc14e7ccc45216b7464253d0420e_img.jpg b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/fcdffc14e7ccc45216b7464253d0420e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f5e5780522bebe0a28cb9a313925574f02db71cc --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/fcdffc14e7ccc45216b7464253d0420e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ba467fb382eef7e0dea85dec24556c18a21b893157f26874013d720336fb04dc +size 4122 diff --git a/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/raw.md b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..da35b1cacce56b80d7f10dfab3d337197a9dee4d --- /dev/null +++ b/marked/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00/raw.md @@ -0,0 +1,900 @@ + + +# **O-RAN Security Focus Group (SFG)** + +## **Study on Security for Non-RT-RIC** + +--- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them + +# **O-RAN Security Focus Group (SFG)** + +## **Study on Security for Non-RT-RIC** --- + +# --- Revision History + +| Date | Revision | Author | Description | +|------------|----------|--------|---------------| +| 2022.03.08 | 01.00 | SFG | First version | + +# Contents + +| | | | +|----|------------------------------------------|----| +| 1 | Revision History..... | 2 | +| 3 | 1 Introduction..... | 5 | +| 4 | 1.1 Scope..... | 5 | +| 5 | 1.2 Considerations ..... | 5 | +| 6 | 1.3 References..... | 6 | +| 7 | 1.3.1 WG2 Specifications ..... | 6 | +| 8 | 1.3.2 SFG Specifications ..... | 6 | +| 9 | 1.3.3 Other O-RAN Specifications ..... | 6 | +| 10 | 1.3.4 External Inputs..... | 6 | +| 11 | 1.4 Definitions and Abbreviations ..... | 7 | +| 12 | 1.4.1 Definitions ..... | 7 | +| 13 | 1.4.2 Abbreviations and acronyms..... | 8 | +| 14 | 1.4.3 Terms | 9 | +| 15 | 2 Non-RT-RIC Assets..... | 10 | +| 16 | 2.1 Architecture ..... | 10 | +| 17 | 2.2 Framework..... | 11 | +| 18 | 2.3 Functions..... | 12 | +| 19 | 2.4 Interfaces..... | 12 | +| 20 | 2.5 Information ..... | 12 | +| 21 | 3 Threats..... | 14 | +| 22 | 3.1 Threat Model..... | 14 | +| 23 | 3.2 Threat Template..... | 14 | +| 24 | 3.3 Potential Exploits..... | 15 | +| 25 | 4 Threat Analysis ..... | 16 | +| 26 | 4.1 Non-RT-RIC Threats ..... | 16 | +| 27 | 4.2 rApps Threats..... | 17 | +| 28 | 4.3 R1 Threats..... | 19 | +| 29 | 4.4 A1 Threats ..... | 21 | +| 30 | 4.5 Protocol Stack Threats ..... | 22 | +| 31 | 4.6 Machine Learning (ML) Threats..... | 23 | +| 32 | 5 Security Controls..... | 24 | +| 33 | 6 Risk Assessment ..... | 25 | +| 34 | 6.1 Risk Assessment for Non-RT-RIC ..... | 25 | + +![O-RAN Alliance logo](d202a27bd66369d201fb78c18d384c6a_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN ALLIANCE' in blue. + +O-RAN Alliance logo + +| | | | | +|----|-----|--------------------------------------------------|----| +| 1 | 6.2 | Risk Assessment for rApps..... | 26 | +| 2 | 6.3 | Risk Assessment for R1 Interface..... | 26 | +| 3 | 6.4 | Risk Assessment for A1 Interface..... | 27 | +| 4 | 7 | Recommendations..... | 28 | +| 5 | | Annex A (informative): xxxxx..... | 30 | +| 6 | | Annex ZZZ : O-RAN Adopter License Agreement..... | 31 | +| 7 | | | | +| 8 | | List of Tables | | +| 9 | | No table of figures entries found. | | +| 10 | | List of Figures | | +| 11 | | No table of figures entries found. | | +| 12 | | | | + +# 1 Introduction + +## 1.1 Scope + +This technical report provides the threat model and risk assessment for the Non-RT-RIC. The report identifies threats and risks and recommends potential security controls to protect against those threats through safeguards or mitigation. + +The steps of the threat modelling process are as follows: + +1. Identify assets: Identify the assets of the Non-RT-RIC that must be protected. +2. Identify threats: Identify the threats that could adversely impact the Non-RT-RIC and threats that can use the Non-RT-RIC to adversely impact other components of the O-RAN system. +3. Identify the attack surface and attack vectors: Identify the points in the Non-RT-RIC where an attacker could gain entry, exploit a vulnerability or misconfiguration, and compromise the system or its data. +4. Measure risk: The extent to which confidentiality, integrity, or availability is threatened, based upon the impact level resulting from an attack and the likelihood of occurrence. +5. Recommend controls: The management, operational, and technical controls for an information system to protect the confidentiality, integrity and availability of the Non-RT-RIC and its information + +## 1.2 Considerations + +The attack surface of the Non-RT-RIC includes its interfaces, functions, and data. Data-at-rest, Data-in-motion, and Data-in-use must be considered. + +The O-RAN Alliance is pursuing a zero-trust architecture (ZTA) for its specifications. A ZTA assumes that the adversary is already inside the network and makes no assumption of implicit trust based upon asset ownership, network location, or physical location. This has the effect of increasing the likelihood scoring. + +Security controls are recommended for specifications of the Non-RT-RIC, which is the responsibility of WG2. Some recommended controls provided in this report may be shared with another responsible O-RAN Alliance working group, such as WG6 or WG10, so that the specification relevant to the recommended control can be properly updated. + +## 1.3 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +### 1.3.1 WG2 Specifications + +[1] Non-RT RIC Architecture, v01.00, O-RAN.WG2.Non-RT-RIC-ARCH-TS-v01.00. + +[2] A1 interface General Aspects & Principles Specification (A1 GA&P), v02.03, O-RAN.WG2.A1GAP-v02.03. + +[3] A1 Interface Transport Protocol Specification (A1 TP), v01.01, O-RAN.WG2.A1TP-v01.01. + +[4] A1 Interface Application Protocol Specification (A1 AP), v03.01, O-RAN.WG2.A1AP-v03.01. + +[5] A1 Interface Type Definitions Specification (A1 TD), v02.00, O-RAN.WG2.A1TD-v02.00. + +[6] R1 General Aspects and Principles (R1GAP), v01.00, O-RAN.WG2.R1GAP-v01.00. + +### 1.3.2 SFG Specifications + +[7] O-RAN Security Requirements Specifications, v01.00.05, O-RAN.SFG.O-RAN-Security-Requirements-Specifications-v01.00.05. + +[8] O-RAN Threat Modelling and Remediation Analysis, v02.00.02, O-RAN.SFG.O-RAN-Threat-Model-v02.00.02. + +[9] O-RAN Security Test Specifications, v01.00, O-RAN.SFG.Security-Test-Specifications-v01.00. + +### 1.3.3 Other O-RAN Specifications + +[10] O-RAN Architecture Description, v06.00, O-RAN.WG1.O-RAN-Architecture-Description-v06.00. + +[11] O-RAN Drafting Rules, v01.00, O-RAN.TSC.Drafting-Rules.0-v01.00. + +### 1.3.4 External Inputs + +[12] Threat Landscape for 5G Networks, ENISA, . + +[13] Zero Trust Architecture, NIST SP 800-207, NIST, . + +[14] OWASP Top 10 Web Application Security Risks, 2021, . + +[15] OWASP Top 10 Proactive Controls, 2021, . + +- [16] Cloud Security Alliance (CSA), Top Threats to Cloud Computing: Egregious Eleven, 2019, . +- [17] Cloud Security Alliance (CSA), Cloud Controls Matrix (CCM), v4, 2021, . +- [18] ISO/IEC 27001:2013 Information Security Management System (ISMS). +- [19] NIST SP 800-53r5, Security and Privacy Controls for Information Systems and Organizations, 2020. +- [20] US National Security Agency (NSA) / Cybersecurity and Infrastructure Security Agency (CISA), Security Guidance for 5G Cloud Infrastructures, Part I, Oct 28, 2021, Part II, Nov 18, 2021, Part III, Dec 2, 2021, Part IV, Dec 16, 2021. (as of Feb 28, 2022). + +## 1.4 Definitions and Abbreviations + +### 1.4.1 Definitions + +For the purposes of the present document, the terms and definitions provided in O-RAN.WG1.O-RAN-Architecture-Description-v06.00 apply: + +**A1:** Interface between non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**A1 policy:** Type of declarative policies expressed using formal statements that enable the non-RT RIC function in the SMO to guide the near-RT RIC function, and hence the RAN, towards better fulfilment of the RAN intent. + +**A1 Enrichment information:** Information utilized by near-RT RIC that is collected or derived at SMO/non-RT RIC either from non-network data sources or from network functions themselves. + +**Near-RT RIC:** O-RAN Near-Real-Time RAN Intelligent Controller: A logical function that enables near-real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. It may include AI/ML (Artificial Intelligence / Machine Learning) workflow including model training, inference and updates. + +**Non-RT RIC:** O-RAN Non-Real-Time RAN Intelligent Controller: A logical function within SMO that drives the content carried across the A1 interface. It is comprised of the Non-RT RIC Framework and the Non-RT RIC Applications (rApps) whose functions are defined below. + +**Non-RT RIC Applications (rApps):** Modular applications that leverage the functionality exposed via the Non-RT RIC Framework's R1 interface to provide added value services relative to RAN operation, such as driving the A1 interface, recommending values and actions that may be subsequently applied over the O1/O2 interface and generating "enrichment information" for the use of other rApps. The rApp functionality within the Non-RT RIC enables non-real-time control and optimization of RAN elements and resources and policy-based guidance to the applications/features in Near-RT RIC. + +![O-RAN Alliance logo](b5bb259847073c5fd0f9a6b4a4504b67_img.jpg) + +O-RAN Alliance logo + +**Non-RT RIC Framework:** That functionality internal to the SMO that logically terminates the A1 interface to the Near-RT RIC and exposes to rApps, via its R1 interface, the set of internal SMO services needed for their runtime processing. The Non-RT RIC Framework functionality within the Non-RT RIC provides AI/ML workflow including model training, inference and updates needed for rApps. + +**SMO:** A Service Management and Orchestration system + +**R1 Interface:** Interface between rApps and Non-RT RIC framework via which R1 Services can be produced and consumed. + +**R1 Services:** A collection of services including, but not limited to, service registration and discovery services, authentication and authorization services, AI/ML workflow services, and A1, O1 and O2 related services. + +### 1.4.2 Abbreviations and acronyms + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 and the following apply: + +| | | +|-------|-------------------------------------| +| AI | Artificial Intelligence | +| DAR | Data at Rest | +| DIM | Data in Motion | +| DIU | Data in Use | +| eNB | eNodeB (applies to LTE) | +| FTP | File Transfer Protocol | +| FTPS | File Transfer Protocol Secure | +| gNB | gNodeB (applies to NR) | +| HTTP | Hypertext Transfer Protocol | +| HTTPS | Hypertext Transfer Protocol Secure | +| JSON | JavaScript Object Notation | +| KPI | Key Performance Indicator | +| KQI | Key Quality Indicator | +| ML | Machine Learning | +| MNO | Mobile Network Operator | +| NF | Network Function | +| PII | Personally Identifiable Information | + +![O-RAN Alliance logo](75f60cca7dbb0e8b244d0195e79a4cd8_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN ALLIANCE' in blue. + +O-RAN Alliance logo + +| | | | +|---|------|--------------------------------------| +| 1 | PTP | Precision Timing Protocol | +| 2 | RBAC | Role-based Access Control | +| 3 | REST | Representational State Transfer | +| 4 | RIC | RAN Intelligent Controller | +| 5 | RT | Real-Time | +| 6 | SMO | Service Management and Orchestration | +| 7 | SSH | Secure Shell | +| 8 | TCP | Transmission Control Protocol | +| 9 | TLS | Transport Layer Security | + +10 + +###### 11 1.4.3 Terms + +12 This document uses the verbal forms for the expression of provisions as defined in O-RAN.TSC.Drafting-Rules.0-v01.00. + +# 2 Non-RT-RIC Assets + +## 2.1 Architecture + +The primary goal of non-RT RIC is to support non-real-time intelligent radio resource management, higher layer procedure optimization, policy optimization in RAN, and providing AI/ML models to near-RT RIC and other RAN functions. The A1 interface supports communication & information exchange between non-RT RIC and near-RT RIC, key objective of A1 interface is to support policy-based guidance of near-RT RIC functions/use-cases, transmission of enrichment information in support of AI/ML models into near-RT RIC, and basic feedback mechanisms from near-RT RIC. + +The non-RT-RIC architecture is shown in the Figure 2.1-1 below. The Non-RT-RIC Reference Architecture is a logical architecture, not an implementation architecture. The Non-RT-RIC can be one black box or multiple disaggregated services. + +US National Institute of Standards and Technology (NIST) defines Attack Surface as: + +*The set of points on the boundary of a system, a system element, or an environment where an attacker can try to enter, cause an effect on, or extract data from, that system, system element, or environment.* [[https://csrc.nist.gov/glossary/term/attack\\_surface](https://csrc.nist.gov/glossary/term/attack_surface)] + +The Attack Surface of the Non-RT-RIC can be grouped into Functions, Interfaces, and Information, which each having assets that should be protected. These assets, as listed in the subsections below, are addressed in this report. Where an asset name is listed is indication that this asset has been identified in the O-RAN Security Threat Modeling and Remediation Analysis document [O-RAN.WG1.SFG.Threat-Model-v02.00]. + +The Non-RT-RIC attack surface also includes Application On-Boarding, SMO, O-Cloud, Machine Learning, etc. These are relevant to securing the Non-RT-RIC, but are not exclusive to the Non-RT-RIC. These points of the O-RAN attack surface are out of scope for this work item and should be further addressed in separate work items. + +![Figure 2.1-1 Non-RT-RIC Reference Logical Architecture [1]. This diagram illustrates the Non-RT-RIC Reference Logical Architecture. It shows the SMO Framework (Service Based Interface) and the Non-RT RIC (Non-Real Time Radio Intelligent Controller) components. The SMO Framework includes 'Other SMO framework functions' and 'External AI/ML services'. The Non-RT RIC includes 'rApp' (Radio Application) and 'R1 termination'. The Non-RT RIC framework includes 'R1 Service exposure functions', 'Other Non-RT RIC framework functions', 'A1 related functions', 'A1 termination', 'Data management and exposure functions', 'AI/ML workflow functions', 'External terminations', 'O2 related functions', and 'O1 related functions'. The diagram also shows 'External AI/ML sources', 'External Oversight', 'O2 termination', 'O1 termination', 'O-Cloud', 'Near-RT RIC', and 'E2 Nodes'. The diagram uses various symbols to represent different types of functions and interfaces: solid blue boxes for functions anchored inside the Non-RT RIC framework, solid orange boxes for functions anchored outside, dashed boxes for non-anchored functions, solid lines for O-RAN defined interfaces, double-headed arrows for external interfaces, and vertical lines with dots for production and consumption of R1 services. Dashed lines represent implementation-specific interfaces.](61d923937ec1e9aa742f0a035a3c5603_img.jpg) + +Figure 2.1-1 Non-RT-RIC Reference Logical Architecture [1]. This diagram illustrates the Non-RT-RIC Reference Logical Architecture. It shows the SMO Framework (Service Based Interface) and the Non-RT RIC (Non-Real Time Radio Intelligent Controller) components. The SMO Framework includes 'Other SMO framework functions' and 'External AI/ML services'. The Non-RT RIC includes 'rApp' (Radio Application) and 'R1 termination'. The Non-RT RIC framework includes 'R1 Service exposure functions', 'Other Non-RT RIC framework functions', 'A1 related functions', 'A1 termination', 'Data management and exposure functions', 'AI/ML workflow functions', 'External terminations', 'O2 related functions', and 'O1 related functions'. The diagram also shows 'External AI/ML sources', 'External Oversight', 'O2 termination', 'O1 termination', 'O-Cloud', 'Near-RT RIC', and 'E2 Nodes'. The diagram uses various symbols to represent different types of functions and interfaces: solid blue boxes for functions anchored inside the Non-RT RIC framework, solid orange boxes for functions anchored outside, dashed boxes for non-anchored functions, solid lines for O-RAN defined interfaces, double-headed arrows for external interfaces, and vertical lines with dots for production and consumption of R1 services. Dashed lines represent implementation-specific interfaces. + +Figure 2.1-1 Non-RT-RIC Reference Logical Architecture [1] + +## 2.2 Framework + +- ASSET-C-11: Non-RT-RIC, see O-RAN.WG2.Non-RT-RIC-ARCH-TS-v01.00 + +## 2.3 Functions + +The functions in the scope of this document include the rApps, R1 Termination, and A1 Termination. The other functions in the Non-RT RIC framework as shown in Figure 2.1-1 are out of scope. + +- **ASSET-C-10:** rApps, see O-RAN.WG2.Non-RT-RIC-ARCH-TS-v01.00 +- **ASSET-C-13:** A1 termination, see O-RAN.WG2.A1GAP-v02.03, A1 interface General Aspects & Principles Specification (A1 GA&P) +- **ASSET-C-15:** R1 termination, see O-RAN.WG2.R1GAP-v01.00, R1 General Aspects and Principles + +## 2.4 Interfaces + +- **ASSET-C-14:** A1 interface, including the protocol stack, O-RAN.WG2.A1GAP-v02.03, A1 interface General Aspects & Principles Specification (A1 GA&P) +- **ASSET-C-16:** R1 interface, including the protocol stack, O-RAN.WG2.R1GAP-v01.00, R1 General Aspects and Principles +- **ASSET-C-17:** External Interfaces + - NOTE: External interfaces are use case specific interfaces that are not standardized in O-RAN. Security of these interfaces is outside the scope of this work item and recommended to be outside the scope of the O-RAN Alliance. + +## 2.5 Information + +- Interface Information + - **ASSET-D-07:** A1 Policies + - **ASSET-D-08:** A1 Enrichment Information + - **ASSET-D-28:** R1 Observables +- Secret Stores – + - NOTE: Secret Stores is a SMO service provided to Non-RT-RIC. Securing the secret stores is outside the scope of this work item. This includes the following assets: + - **ASSET-D-16:** X.509 certificates + +- **ASSET-D-17:** Security private keys +- **ASSET-D-20:** Administrator credentials +- ML Data + - NOTE: Security for ML Data is an evolving technology and should be treated across all of O-RAN as a separate work item outside the scope of this work item. This includes the following assets: + - **ASSET-D-25:** Training or test data: data sets collected externally or internally from the Near-RT RIC, O-CU and O-DU and passed to the ML training hosts in a ML system. + - **ASSET-D-26:** The trained ML model which includes intellectual property, numerous configured hyperparameters and millions of learned parameters. + - **ASSET-D-27:** The ML prediction results built into the model (e.g. expected outcomes) + - **ASSET-D-28:** The behavior of the ML system including tasks for data collection, data wrangling, pipeline management, model retraining, and model deployment. +- PII + - **ASSET-D-30:** O-RAN specific UE IDs + +# --- 3 Threats + +## 3.1 Threat Model + +For identifying threats, we are using STRIDE: + +1. S - Spoofing identity. An application or program can masquerade as another to gain advantages not typically allowed for that program. +2. T - Tampering with data. This involves the malicious modification of data, including making unauthorized changes to a database and alteration of data as it flows between computers. +3. R - Repudiation. A user or program refuses the authenticity of a good or reasonable command or action. +4. I - Information disclosure. This involves the exposure of information to individuals with unauthorized access to it. For example, users gain the ability to read a file that they normally would not have been granted access to, or an intruder can read data in transit between computers. +5. D - Denial of service. These attacks deny service to valid users, such as making a website unavailable or unusable by flooding it with illegitimate requests to keep legitimate users without access. +6. E - Elevation of privileges. An unauthorized user gains privileged rights to access previously not granted to compromise or destroy the system, such as a change in membership. + +| Threat types | Impact types | +|------------------------|-----------------| +| Spoofing | Authenticity | +| Tampering | Integrity | +| Repudiation | Non-repudiation | +| Information disclosure | Confidentiality | +| Denial of Service | Availability | +| Elevation of Privilege | Authorization | + +## 3.2 Threat Template + +Template to present the threat characteristics: + +| Threat ID | | +|--------------------|---------------------------------------------------------------------------------------------------------------| +| Threat title | | +| Threat description | | +| Threat type | Spoofing
Tampering
Repudiation
Information disclosure
Denial of Service
Elevation of Privilege | +| Vulnerabilities | | +| Impact type | Authenticity
Integrity
Non-repudiation
Confidentiality
Availability
Authorization | +| Affected Assets | | + +## 3.3 Potential Exploits + +A threat analysis is facilitated by an understanding of potential threats, as identified by the Cloud Security Alliance (CSA) and the Open Web Application Security Project (OWASP). + +The CSA Top Threats to Cloud was updated in 2019 to the “Egregious Eleven” [16], which includes the following: + +1. Data Breaches +2. Misconfiguration and Inadequate Change Control +3. Lack of Cloud Security Architecture and Strategy +4. Insufficient Identity, Credential, Access, and Key Management +5. Account Hijacking +6. Insider Threat +7. Insecure Interfaces and APIs +8. Weak Control plane +9. Metastructure and Applistructure Failures +10. Limited Cloud Usage Visibility +11. Abuse and Nefarious Uses of Cloud Services + +The OWASP Top 10 Web Application Security Risks [14] was updated in 2021 to include the following: + +- A01:2021 Broken Access Control +- A02:2021 Cryptographic Failure +- A03:2021 Injection (including Cross-Site Scripting) +- A04:2021 Insecure Design +- A05:2021 Security Misconfiguration +- A06:2021 Vulnerable and Outdated Components +- A07:2021 Identification and Authentication Failures +- A08:2021 Software and Data Integrity Failures (including Insecure Deserialization) +- A09:2021 Security Logging and Monitoring Failures +- A10:2021 Server-Side Request Forgery + +The threats listed above are considered in the Non-RT-RIC threat analysis where relevant to O-RAN and the Non-RT-RIC. + +# 4 Threat Analysis + +## 4.1 Non-RT-RIC Threats + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-NONRTRIC-01 | +| Threat title | An attacker penetrates the Non-RT RIC to cause a denial of service or degrade the performance | +| Threat description |

An attacker penetrates the Non-RT RIC through A1 interface or from external sources through SMO and attempts to trigger a Denial of Service or degrade the performance of non-RT RIC so that non-RT RIC would not be liable for ensuring:

  • • The monitoring or tracing of the network to understand the effect of the A1 policy on performance in Near-RT RIC
  • • The update of A1 policy
  • • The exposure and secure delivery of A1 Enrichment Information to near-RT RIC
  • • The setup of access control rules and the selection of which Enrichment Information ID (EiId) are exposed to a near-RT RIC
| +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Non-RT-RIC | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-NONRTRIC-02 | +| Threat title | UE tracking in the Non-RT RIC | +| Threat description | An attacker gains access to the Non-RT RIC through the SMO to gain access to sensitive information for UE tracking. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Non-RT-RIC | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T- NONRTRIC-03 | +| Threat title | Data Corruption/Modification | +| Threat description | An attacker gains access to the Non-RT RIC through the SMO to cause Data Corruption/Modification. For example, a malicious actor who gains unauthorized access to the Non-RT-RIC can modify policy to pass a “False Policy” to the Near-RT-RIC. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | Non-RT-RIC, Near-RT-RIC, A1 interface | + +## 4.2 rApps Threats + +rApps have the ability to manipulate behavior of a certain cell, a group of UEs, and a specific UE. A malfunctioning rApp could potentially be used to track or impact service for a certain UE-Id or degrade service in an area. + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-01 | +| Threat title | Conflicting rApps unintentionally or maliciously impact O-RAN system functions to degrade performance or trigger a DoS | +| Threat description |

rApps in the Non-RT RIC can be provided by different vendors. For example, one vendor can provide the rApp for Carrier license scheduling and another vendor provide the rApp for energy saving, etc.

This creates the risk that different rApps will take conflicting decisions at the same instance in time for the same user. Such conflicts between rApps include:

  • • Direct conflicts: different rApps request change for the same parameter.
  • • Indirect conflicts: different rApps request change to different parameters that will create opposite effects.
  • • Implicit conflicts: different rApps request change to different parameters that are not creating any obvious opposite effect but result in an overall network performance degradation, instabilities, etc.

These conflicts are difficult to mitigate since dependencies are impossible to observe.

| +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | rApps | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-02 | +| Threat title | An attacker exploits rApp vulnerabilities | +| Threat description |

Vulnerabilities can potentially exist in any rApp. If attackers can find exploitable rApp, they can disrupt the offered network service and potentially take over another rApp or the non-RT RIC.

The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 interface, extract sensitive information, etc.

| +| Threat type | Tampering, Denial of Service | +| Impact type | Integrity, Availability | +| Affected Asset | rApps | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-03 | +| Threat title | An attacker exploits rApps misconfiguration | +| Threat description |

Security misconfiguration, such as open ports or enabled unused protocols, can potentially exist in an rApp. If attackers can find exploitable rApp, they can disrupt the offered network service and potentially take over another rApp or the whole non-RT RIC.

The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 interface, extract sensitive information, etc.

| +| Threat type | Information Disclosure, Tampering, Denial of Service | + +| | | +|-----------------------|------------------------------------------| +| Impact type | Confidentiality, Integrity, Availability | +| Affected Asset | rApps | + +1 + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-04 | +| Threat title | An attacker bypasses authentication and authorization | +| Threat description | An Attacker can exploit an rApp that has weak or misconfigured authentication and authorization to gain access to the rApp and pose as a tenant. | +| Threat type | Elevation of Privilege | +| Impact type | Authenticity, Authorization | +| Affected Asset | rApps | + +2 + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-05 | +| Threat title | An attacker exploits malicious rApp | +| Threat description | An untrusted source may intentionally provide a malicious rApp. A trusted source may have a backdoor intentionally inserted in the rApp. If attackers can find exploitable rApp, they can disrupt the offered network service and potentially take over another rApp or the whole non-RT RIC.

Malicious rApps could impact non-RT RIC functions such as AI/ML model training, A1 policy management, Enrichment information management, Network Configuration Optimization in the purpose of performance degradation, DoS, enrichment data sniffing (UE location, trajectory, navigation information, GPS data, etc.), etc. | +| Threat type | Information disclosure, Tampering, Denial of Service | +| Impact type | Confidentiality, Integrity, Availability | +| Affected Asset | rApps | + +3 + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-06 | +| Threat title | An attacker bypasses authentication and authorization using an injection attack | +| Threat description | It is possible that an attacker to submit requests without prior authentication and authorization by executing an injection attack to manipulate configurations, access logs, perform remote code execution, etc. | +| Threat type | Tampering, Information disclosure, Denial of Service | +| Impact type | Integrity, Confidentiality, Availability | +| Affected Asset | rApps, R1 Termination | + +4 + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-07 | +| Threat title | rApp exploits O1 services | +| Threat description | A malicious rApp or a trusted but compromised rApp can exploit O1 services across the R1 interface | +| Threat type | Tampering, Information disclosure, Denial of Service | + +| | | +|-----------------------|------------------------------------------| +| Impact type | Integrity, Confidentiality, Availability | +| Affected Asset | rApps | + +## 4.3 R1 Threats + +The R1 interface facilitates inter-connection between rApps and Non-RT RIC framework supplied by different vendors, and provides a level of abstraction between rApps and Non-RT RIC framework/SMO that can be the consumers and or producers of R1 services. + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-01 | +| Threat title | An attacker gains unauthorized access to services | +| Threat description | “Service management and exposure services Producer” determines whether the Service Producer is authorized to produce the service. An attacker can perform a spoofing attack to gain unauthorized access to R1 services. | +| Threat type | Spoofing | +| Impact type | Authorization | +| Affected Asset | R1, rApps | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-02 | +| Threat title | Exploit of Service Heartbeat | +| Threat description | Attacker can exploit the Service Heartbeat on the R1 by modifying or inserting heartbeat messages to cause denial of service | +| Threat type | Tampering, Denial of Service | +| Impact type | Integrity, Availability | +| Affected Asset | R1, rApps | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-03 | +| Threat title | Bypass authentication to Request Data | +| Threat description | Attacker can exploit password-based authentication on the R1 to request unauthorized data. Weak password management can easily be exploited. (Certificate-based mutual authentication using TLS and PKI X.509 certificates is recommended). | +| Threat type | Spoofing | +| Impact type | Authenticity, Authorization | +| Affected Asset | R1, rApps | + +| | | +|------------------|---------| +| Threat ID | T-R1-04 | +|------------------|---------| + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | An attacker performs spoofing attack to discover data | +| Threat description | “Data registration and discovery service producer” determines whether the Data Producer is authorized to produce the data types. An attacker can perform a spoofing attack to discover available data. | +| Threat type | Spoofing | +| Impact type | Authorization | +| Affected Asset | R1, rApps | + +1 + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-05 | +| Threat title | An attacker gains unauthorized access to data | +| Threat description | An attacker can perform a spoofing attack to exploit the Data request and subscription service for the purpose to gain unauthorized access to data. | +| Threat type | Spoofing | +| Impact type | Authorization | +| Affected Asset | R1, rApps | + +2 + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-06 | +| Threat title | Compromised Data Request | +| Threat description | Data Consumers consume the “Data request and subscription service” to request data instances or subscribe to them. An attacker can modify a request to force the consumer to receive a different data set than that intended. Without checks, the received data could be processed, leading to erroneous decisions or triggers. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | R1, rApps | + +3 + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-07 | +| Threat title | Compromised data delivery | +| Threat description |

Data delivery messages relate to a particular data request or subscription. The data can be delivered to the Data Consumer in different ways, including:

  • • as part of the payload of a data delivery message,
  • • as a data stream,
  • • from e.g., a REST endpoint, a message bus or object store location.

An attacker can perform snooping, injection, or modification attacks in the Delivery of Data process.

| +| Threat type | Information Disclosure and Tampering | +| Impact type | Confidentiality, Integrity | +| Affected Asset | R1, rApps | + +4 + +## 4.4 A1 Threats + +The purpose of the A1 interface is to enable the Non-RT RIC function to provide policy-based guidance, ML model management and enrichment information to the Near-RT RIC function for RAN can optimization. The Non-RT RIC can provide enrichment information over the A1 interface to support the policy enforcement in the Near-RT RIC. The A1 interface is used for discovery, request and delivery of A1 Enrichment Information and discovery of External Enrichment Information. + +![Diagram showing the A1 interface between Non-RT-RIC and Near-RT-RIC. A double-headed arrow labeled 'A1' connects the two boxes.](84e1e63b6b13269ee4801e88cc6e6e1e_img.jpg) + +``` + +graph TD + Non-RT-RIC[Non-RT-RIC] <--> |A1| Near-RT-RIC[Near-RT-RIC] + +``` + +Diagram showing the A1 interface between Non-RT-RIC and Near-RT-RIC. A double-headed arrow labeled 'A1' connects the two boxes. + +Figure. A1 interface between the Non-RT RIC and the Near-RT RIC. + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-A1-01 | +| Threat title | Untrusted peering between Non-RT-RIC and Near-RT-RIC | +| Threat description | Malicious Non-RT-RIC peers with a Near-RT-RIC over the A1 interface, or a malicious Near-RT-RIC peers with a Non-RT-RIC over the A1 interface, due to weak mutual authentication. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | Non-RT-RIC, Near-RT-RIC, A1 interface | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-A1-02 | +| Threat title | Malicious function or application monitors messaging across A1 interface | +| Threat description | Internal threat actor can gain access to the messaging across the A1 interface for a MiTM attack to read policy. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Non-RT-RIC, Near-RT-RIC, A1 interface | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-A1-03 | +| Threat title | Malicious function or application modifies messaging across A1 interface | +| Threat description | Internal threat actor can gain access to the messaging across the A1 interface for a MiTM attack to modify or inject policy. This can result in the Near-RT RIC receiving malicious policy. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | Non-RT-RIC, Near-RT-RIC, A1 interface | + +## 4.5 Protocol Stack Threats + +The A1 and R1 interfaces use the REST protocol stack shown in the figure below. The transport network layer is built on IP transport. TCP provides the communication service at the transport layer. HTTP is the application-level protocol used providing reliable transport of messages. TLS provides secure HTTP connections for secure transport of messages. The application layer protocol is based on a RESTful approach with transfer of JSON formatted policy statements. Each of these protocols has known vulnerabilities that can be exploited by a malicious actor. + +| | | +|------------------|------| +| Data Interchange | JSON | +| Application | HTTP | +| Security | TLS | +| Transport Layer | TCP | +| Network layer | IP | +| Data Link Layer | L2 | +| Physical Layer | L1 | + +Figure. REST Protocol Stack for the A1 and R1 Interfaces + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ProtocolStack-01 | +| Threat title | REST API Exploits | +| Threat description | The A1 and R1 interfaces use the REST API. REST API common attacks include injection, cross site scripting, and DoS attacks that can exploit common vulnerabilities if proper controls are not used to protect against vulnerabilities. | +| Threat type | Spoofing, Tampering, Information Disclosure | +| Impact type | Confidentiality, Integrity, Authenticity | +| Affected Asset | Non-RT-RIC, Near-RT-RIC, A1 interface | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ProtocolStack-02 | +| Threat title | REST API – Broken Object Level Authorization | +| Threat description | The A1 and R1 interfaces use the REST API, which could expose object identifiers without proper authorization checks. | +| Threat type | Information Disclosure | + +| | | +|-----------------------|---------------------------------------| +| Impact type | Authorization | +| Affected Asset | Non-RT-RIC, Near-RT-RIC, A1 interface | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ProtocolStack-03 | +| Threat title | JSON Exploits | +| Threat description | The A1 and R1 interfaces use JSON formatted policy statements. JSON attacks include injection, deserialization, web token, and cross site scripting attacks that can exploit common vulnerabilities if proper controls are not used to protect against vulnerabilities. | +| Threat type | Spoofing, Tampering, Information Disclosure | +| Impact type | Confidentiality, Integrity, Authenticity | +| Affected Asset | Non-RT-RIC, Near-RT-RIC, A1 interface | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ProtocolStack-04 | +| Threat title | HTTP Exploits | +| Threat description | The A1 and R1 interfaces use HTTPS. DDoS attacks include HTTP GET Flood, Garbage Flood, and Reverse Bandwidth Floods. Other well known HTTP attacks include injection attacks, such as Cross-Site Scripting (XSS) and SQL injection. | +| Threat type | Spoofing, Tampering, Information Disclosure, DDoS | +| Impact type | Confidentiality, Integrity, Authenticity, Availability | +| Affected Asset | Non-RT-RIC, Near-RT-RIC, A1 interface | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------| +| Threat ID | T-ProtocolStack-05 | +| Threat title | TCP Volumetric DDoS | +| Threat description | The A1 and R1 interfaces use TCP. TCP DDoS attacks include TCP SYN Flood, ACK Flood, and RST Flood. | +| Threat type | DDoS | +| Impact type | Availability | +| Affected Asset | Non-RT-RIC, Near-RT-RIC, A1 interface | + +## 4.6 Machine Learning (ML) Threats + +ML threats in this subsection should be specific to the Non-RT-RIC. General ML Threats applicable to the O-RAN architecture should be addressed in a separate work item. + +For Further Study (FFS). + +# 5 Security Controls + +Industry recommendations for strong security controls are provided from sources such as the OWASP Top 10 Proactive Controls [15], Cloud Security Alliance (CSA) Cloud Control Matrix (CCM) [17], ISO/IEC 27001:2013 Information Security Management System (ISMS) [18], NIST SP 800-53r5 Security and Privacy Controls for Information Systems and Organizations [19], and Cybersecurity and Infrastructure Security Agency (CISA) Security Guidance for 5G Cloud Infrastructures [20]. + +With consideration of these external sources, the following security controls should be considered for the Non-RT-RIC risk analysis: + +Control-1: TLS with PKI and X.509 certificates + +Control-2: OAuth 2.0 + +Control-3: IAM (using RBAC, ABAC, PBAC, TBAC) + +Control-4: Encryption for Data at Rest + +Control-5: Integrity Protection for Data at Rest + +Control-6: Certificate Management + +Control-7: Message Authentication + +Control-8: Message Integrity Protection + +Control-9: Digital Signatures + +Control-10: Logging + +Control-11: Configuration Validation + +Control-12: Conflict detection and resolution + +Control-13: Encryption for Data in Motion + +Control-14: Integrity Protection for Data in Motion + +# 6 Risk Assessment + +This section provides risk assessment tables for each of the identified assets: Non-RT RIC, R1 interface, A1 interface, and rApps. These tables list the assets, threats, impacts, and possible security controls. + +A malicious actor may be a nation-state adversary, cybercriminal, or employee. Risk scoring includes Likelihood and Impact. + +Likelihood scoring is based upon current security controls. Likelihood scoring does not consider security controls that may be potentially specified in the future. + +Likelihood scoring considers a zero trust architecture which protects against internal threat actors. Likelihood scores are higher for a zero trust architecture (ZTA) because internal threats must be considered in addition to external threats. In a ZTA it cannot be assumed that perimeter defenses are sufficient. As a result, scored Likelihood = Medium, at a minimum. Reconnaissance type attacks can be scored Likelihood = High while damaging/availability attacks can be scored Likelihood = Medium. The reason is that threat actors are less likely to perform damaging attacks that are quickly and easily detected. Advanced Persistent Threats (APTs) typically move laterally in anonymous fashion to prevent detection while providing reconnaissance. + +Zero trust architecture removes the ability to assume perimeter security is sufficient. The Non-RT RIC must be protected from untrusted external sources attempting to have access, while also assuming the adversary is already inside the network with access to its functions. As a result, the Non-RT RIC cannot have its security posture founded on the assumption the SMO is secure. + +## 6.1 Risk Assessment for Non-RT-RIC + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/ Likelihood Raw Score | Possible Security Controls | Security Control-Id | Comments | +|------------|------------|---------------|--------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------|-----------------------------------------------------|----------------------------------|----------------------------------------------------------------------------------------------------------------------------------| +| ASSET-C-11 | Non-RT-RIC | T-NONRTRIC-01 | An attacker gains access to the Non-RT RIC through the SMO to cause a denial of service or degrade the performance of the Non-RT-RIC | Impact = High
Likelihood = Medium | IAM, Logging | Control-3, Control-10 | WG1 ATG is starting a study on SMO and Non-RT-RIC integration. Secure integration should be addressed as the requirements evolve | +| ASSET-C-11 | Non-RT-RIC | T-NONRTRIC-02 | An attacker gains access to the Non-RT RIC through the SMO for UE tracking | Impact = High
Likelihood = High | Encryption of Data at Rest, IAM, Logging | Control-3, Control-4, Control-10 | WG1 ATG is starting a study on SMO and Non-RT-RIC integration. Secure integration should be addressed as the requirements evolve | +| ASSET-C-11 | Non-RT-RIC | T-NONRTRIC-03 | An attacker gains access to the Non-RT RIC through the SMO to cause Data Corruption/Modification | Impact = High
Likelihood = Medium | Integrity protection for Data at Rest, IAM, Logging | Control-3, Control-5, Control-10 | WG1 ATG is starting a study on SMO and Non-RT-RIC integration. Secure integration should be addressed as the requirements evolve | + +Table 6.1-1 Risk Assessment for Non-RT-RIC + +## 6.2 Risk Assessment for rApps + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/Likelihood Score | Security Controls | Security Control-Id | Comments | +|------------|------------|-----------|-----------------------------------------------------------------------------------------|--------------------------------------|-------------------------------------------------------|-----------------------------------|----------| +| ASSET-C-10 | rAPPs | T-rAPP-01 | Conflicting rApps impact O-RAN system functions to degrade performance or trigger a DoS | Impact = High
Likelihood = Medium | IAM, Logging | Control-12 | | +| ASSET-C-10 | rAPPs | T-rAPP-02 | An attacker exploits rApp vulnerability for data breach or denial of service | Impact = High
Likelihood = Medium | IAM, Logging, Data protection | Control-3, Control-4, Control-10 | | +| ASSET-C-10 | rAPPs | T-rAPP-03 | An attacker exploits rApps misconfiguration | Impact = High
Likelihood = Medium | IAM, Logging | Control-11 | | +| ASSET-C-10 | rAPPs | T-rAPP-04 | An attacker bypasses authentication and authorization | Impact = High
Likelihood = Medium | TLS, PKI, X.509, OAuth 2.0, IAM | Control-1, Control-2, Control-3 | | +| ASSET-C-10 | rAPPs | T-rAPP-05 | An attacker deploys and exploits malicious rApp | Impact = High
Likelihood = Medium | IAM, Logging | Control-9, Control-11 | | +| ASSET-C-10 | rAPPs | T-rAPP-06 | An attacker bypasses authentication and authorization using an injection attack | Impact = High
Likelihood = Medium | Data encryption, security configuration validation | Control-4, Control-11 | | +| ASSET-C-10 | rAPPs | T-rAPP-07 | rApp exploits services | Impact = High
Likelihood = Medium | Digital Signatures, Logging, Configuration Validation | Control-9, Control-10, Control-11 | | + +Table 6.2-1 Risk Assessment for rApps + +## 6.3 Risk Assessment for R1 Interface + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/Likelihood Score | Security Controls | Security Control-Id | Comments | +|------------|--------------|-----------|------------------------------------------------------------------------|--------------------------------------|--------------------------------------------------------------------|---------------------------------------------|----------| +| ASSET-C-16 | R1 interface | T-R1-01 | A malicious actor gains unauthorized access to R1 services | Impact = High
Likelihood = Medium | TLS, PKI, X.509 certificates, Certificate Management, IAM, Logging | Control-1, Control-3, Control-6, Control-10 | | +| ASSET-C-16 | R1 interface | T-R1-02 | Attacker modifies Service Heartbeat message to cause Denial of Service | Impact = High
Likelihood = Medium | Integrity protection, Message Authentication, Logging | Control-7, Control-8, Control-10 | | +| ASSET-C-16 | R1 interface | T-R1-03 | Malicious actor bypasses authentication to Request Data | Impact = High
Likelihood = High | TLS, PKI, X.509, Logging | Control-1, Control-10 | | + +| | | | | | | | +|------------|--------------|---------|---------------------------------------------------------|------------------------------------|--------------|-----------------------| +| ASSET-C-16 | R1 interface | T-R1-04 | Malicious actor bypasses authorization to Discover Data | Impact = High
Likelihood = High | IAM, Logging | Control-3, Control-10 | +|------------|--------------|---------|---------------------------------------------------------|------------------------------------|--------------|-----------------------| + +| | | | | | | | +|------------|--------------|---------|----------------------------------------------------------------|--------------------------------------|--------------------------------------------------------------------------|---------------------------------------------| +| ASSET-C-16 | R1 interface | T-R1-05 | A malicious actor gains unauthorized access to data | Impact = High
Likelihood = High | TLS, PKI, X.509 certificates, Certificate Management, IAM, Logging | Control-1, Control-3, Control-6, Control-10 | +| ASSET-C-16 | R1 interface | T-R1-06 | Malicious actor modifies a Data Request | Impact = High
Likelihood = Medium | Integrity protection for Data in Motion, Message Authentication, Logging | Control-7, Control-8, Control-10 | +| ASSET-C-16 | R1 interface | T-R1-07 | Malicious actor compromises Data Delivery to the Data Consumer | Impact = High
Likelihood = High | Encryption of Data in Motion using TLS, Logging | Control-1, Control-10 | + +Table 6.3-1 Risk Assessment for R1 Interface + +## 6.4 Risk Assessment for A1 Interface + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/Likelihood Score | Security Controls | Security Control-Id | Comments | +|------------|--------------|-----------|--------------------------------------------------------------------------|--------------------------------------|---------------------------------------------------------------|----------------------------------|----------| +| ASSET-C-14 | A1 interface | T-A1-01 | Untrusted peering between Non-RT-RIC and Near-RT-RIC | Impact = High
Likelihood = Medium | TLS, PKI, X.509 certificates, Certificate Management, Logging | Control-1, Control-6, Control-10 | | +| ASSET-C-14 | A1 interface | T-A1-02 | Malicious function or application monitors messaging across A1 interface | Impact = High
Likelihood = High | Encryption of Data in Motion using TLS | Control-1 | | +| ASSET-C-14 | A1 interface | T-A1-03 | Malicious function or application modifies messaging across A1 interface | Impact = High
Likelihood = Medium | Integrity Protection of Data in Motion using TLS | Control-1 | | + +Table 6.4-1 Risk Assessment for A1 Interface + +# 7 Recommendations + +The Security Analysis presented in this technical report used the following process: + +1. Asset identification -> 2. Threat identification -> 3. Threat analysis -> 4. Risk analysis -> 5. Recommend Security Controls + +The Non-RT RIC Reference Architecture is a logical architecture, not an implementation architecture. The Non-RT RIC can be monolithic or multiple disaggregated functions. The Non-RT RIC Framework may be considered an asset for which security controls can be applied. Other critical assets that are part of the Non-RT RIC Framework are rApps, the R1 interface, and the A1 interface, which are considered assets for this security analysis. + +**Recommendation 1:** SFG should update the Security Threat and Remediation document [8] to include the assets identified in this security analysis technical report. A CR will be generated. + +20 threats were identified, which are categorized as 3 Non-RT RIC threats, 7 rApps threats, 7 R1 threats, and 3 A1 threats. In addition, 6 threats for the protocol stack of the R1 and A1 interfaces were identified. + +**Recommendation 2:** SFG should update the Security Threat and Remediation document [8] to include the threats and threat tables created for this security analysis technical report. A CR will be generated. + +Risk analysis included impact-likelihood scoring. All 20 of the identified threats were score either high-medium or high-high. Likelihood scoring was influenced by the consideration of a zero trust architecture (ZTA), which is a publicly expressed goal of the O-RAN Alliance. ZTA is built on the foundational principles that perimeter defenses are insufficient to secure a network as internal external threats pose risk to a network. There are two guidelines for designing a network and its network functions for a ZTA: + +1. There is no implicit trust granted to an asset based upon ownership, physical location, or network location [13]. +2. Assume the adversary is already inside the network [20]. + +**Recommendation 3:** The Non-RT RIC should be protected from untrusted external sources attempting to have access. Specific requirements will be formed as this SFG work item continues. + +**Recommendation 4:** The Non-RT RIC should have security controls implemented to protect its functions and interfaces from internal threats, consistent with a ZTA. Specific requirements will be formed as this SFG work item continues. + +14 security controls were identified for securing the Non-RT RIC to provide protection from confidentiality, integrity, and availability attacks. + +**Recommendation 5:** The SFG should update its Security Requirements Specifications document [7] and Security Protocols Specifications document [9] to provide guidance for use of the suggested security controls. Requirements for these security controls will be developed as this SFG work item continues. The security controls recommended in the Risk Analysis tables in section 6 for the R1 and A1 interfaces should be considered by WG2. + +**Recommendation 6:** Consistent with a ZTA architecture the Non-RT RIC should be secure by design in which its security posture does not assume that the SMO is secure and will provide perimeter protection for the Non-RT-RIC. A new SFG work item should address security of SMO and Non-RT RIC integration. + +Non-RT-RIC has additional attack vectors that have broader scope across O-RAN. These additional attack vectors that are not exclusive to the Non-RT-RIC include secure application on-boarding and lifecycle management of rApps, certificate management, key management, implementation of a secure protocol stack on the A1 and R1 interfaces, security configuration validation, cloud security best practices, ML/AI security, logging security, and secure software development, including secure use of open source software. + +**Recommendation 7:** SFG should address each of these non-exclusive attack vectors mentioned above as work items to be studied in collaboration with the relevant working group of the O-RAN Alliance. In some cases, the SFG itself may be the relevant working group. + +# 1 Annex A (informative): xxxxx + +# Annex ZZZ : O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN + +Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of O-RAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or + +Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance's sole discretion. O-RAN Alliance may freely assign this Agreement. + +### Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +### Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +### Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +1 Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and +2 regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export +3 control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement +4 prohibits any communication that would violate the antitrust laws. + +5 By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, +6 or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this +7 Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, +8 Contributors or Academic Contributors. + +9 In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, +10 void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken +11 from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in +12 full force and effect. Any failure by a party or third party beneficiary to insist upon or enforce performance by another +13 party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or +14 otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or third party +15 beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the +16 same shall be and remain in full force and effect. + +17 \ No newline at end of file diff --git a/marked/SuFG/O-RAN.SuFG.CE-v01.00/03610093e50f03fe4b41c8a6ff7b7ce8_img.jpg b/marked/SuFG/O-RAN.SuFG.CE-v01.00/03610093e50f03fe4b41c8a6ff7b7ce8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0ebd1ddfd58b1bf5f028fea1e57a2e1a891887b3 --- /dev/null +++ b/marked/SuFG/O-RAN.SuFG.CE-v01.00/03610093e50f03fe4b41c8a6ff7b7ce8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1dcc49fa51967cdb0100afc74c8d6cc02609e63b2e3761eac5bec5155d3a92bb +size 4592 diff --git a/marked/SuFG/O-RAN.SuFG.CE-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/SuFG/O-RAN.SuFG.CE-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/SuFG/O-RAN.SuFG.CE-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/SuFG/O-RAN.SuFG.CE-v01.00/83557251ef78793fdb5e0084561b5391_img.jpg b/marked/SuFG/O-RAN.SuFG.CE-v01.00/83557251ef78793fdb5e0084561b5391_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..57863c80390ae918f105ddd028fb323bff9ae558 --- /dev/null +++ b/marked/SuFG/O-RAN.SuFG.CE-v01.00/83557251ef78793fdb5e0084561b5391_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f5bd32277e0004f03cae3205bd3a22c90030c58b322b1c224f4002d85f24f673 +size 95116 diff --git a/marked/SuFG/O-RAN.SuFG.CE-v01.00/984d5c867d6188af195694da985a1b47_img.jpg b/marked/SuFG/O-RAN.SuFG.CE-v01.00/984d5c867d6188af195694da985a1b47_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fdadf67d76b1ca3cdaa7bd76823a3c1102d43a88 --- /dev/null +++ b/marked/SuFG/O-RAN.SuFG.CE-v01.00/984d5c867d6188af195694da985a1b47_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5fcc58179640b4e094bfe3b236ab143c7c47771111919119b05bf4f5233cd21c +size 4503 diff --git a/marked/SuFG/O-RAN.SuFG.CE-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/SuFG/O-RAN.SuFG.CE-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/SuFG/O-RAN.SuFG.CE-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/SuFG/O-RAN.SuFG.CE-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/SuFG/O-RAN.SuFG.CE-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/SuFG/O-RAN.SuFG.CE-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/SuFG/O-RAN.SuFG.CE-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/SuFG/O-RAN.SuFG.CE-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/SuFG/O-RAN.SuFG.CE-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/SuFG/O-RAN.SuFG.CE-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/SuFG/O-RAN.SuFG.CE-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/SuFG/O-RAN.SuFG.CE-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/SuFG/O-RAN.SuFG.CE-v01.00/raw.md b/marked/SuFG/O-RAN.SuFG.CE-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..78e53c8c593323fa1f2de4376c3ba17e045cd9e8 --- /dev/null +++ b/marked/SuFG/O-RAN.SuFG.CE-v01.00/raw.md @@ -0,0 +1,465 @@ + + +# --- **O-RAN Focus Group (Sustainability Focus Group)****Circular economy guidelines on network equipment** + +Copyright © 2022 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +# --- Contents + +| | | +|-------------------------------------------------------|----| +| List of figures ..... | 3 | +| List of tables ..... | 3 | +| Foreword..... | 4 | +| Modal verbs terminology ..... | 4 | +| Executive summary ..... | 4 | +| Introduction ..... | 4 | +| 1 Scope ..... | 5 | +| 2 References ..... | 5 | +| 2.1 Informative references ..... | 5 | +| 3 Definition of terms, symbols and abbreviations..... | 6 | +| 3.1 Terms ..... | 6 | +| 3.2 Symbols ..... | 6 | +| 3.3 Abbreviations..... | 6 | +| 4 Circular economy on network equipment ..... | 7 | +| 4.1 O-CU/O-DU ..... | 13 | +| 4.2 O-RU ..... | 14 | +| A.1 Equipment lifecycle aspects to consider ..... | 16 | +| Revision history ..... | 17 | +| History ..... | 17 | + +# --- List of figures + +| | | +|--------------------------------------------------------------------------------|----| +| Figure A.1-1: Reduction of environmental impact through circular economy ..... | 16 | +|--------------------------------------------------------------------------------|----| + +# --- List of tables + +| | | +|--------------------------------------------------------------------------------------------|----| +| Table 4-1 Circularity aspects and indicators applicable on network equipment ..... | 8 | +| Table 4-2 Priority level definition based on contribution effect to circular economy ..... | 13 | +| Table 4.1-1 O-CU/O-DU priority definition based on circularity economy effect ..... | 13 | +| Table 4.2-1 O-RU priority definition based on circularity economy effect ..... | 14 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +--- + +## Modal verbs terminology + +In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and "cannot" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"must" and "must not" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Executive summary + +The implementation of circular economy transformative model on the telecommunications industry and its network equipment promotes the move to more sustainable business models. It favours both the manufacture of products with eco-design criteria, and the reuse and recycling of these at the end of their useful life. It also contributes to reducing the risk of resource depletion, provides continuity to the supply chain (components, critical raw materials, etc.) and helps reduce GHG emissions. + +This document defines circular economy criteria aspects and indicators applicable on network equipment based on the recommendation ITU-T L.1023 (08/2023) "Assessment method for circularity performance scoring", with the intention to reduce environmental impact through the homogenization and prioritization of said criteria based on the network equipment and its impact on the contribution to the circular economy model. + +--- + +# Introduction + +Circular economy model reduces environmental impact supporting the reduction of material use, recycling, and recovering of product, product parts, components, and materials to circulate them in the value chain for as long as possible. + +The present document identifies circular economy aspects and indicators applicable on network equipment such as: O-CU, O-DU and O-RU including their respective description, contribution and non-contribution cases to circular economy and priority level according to the effect (for customer, environment etc.) of the indicator at hand. + +The objective of this information is to homogenize circularity criteria applicable to network equipment with the aim of reducing its environmental impact during the different phases involved in its life cycle, through improvements that allow achieving the greatest positive effect that contributes to the circular economy in aspects such as: product durability, ability to recycle, repair, reuse, upgrade at equipment level, and finally ability to recycle, repair, reuse, upgrade at manufacturer level. This goal will involve cooperation with stakeholders along the whole of the value chain. + +These guidelines are based on the latest recommendation ITU-T L.1023 (08/2023) "Assessment method for circularity performance scoring". Scoring methodology is out of scope on this document. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e., technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document specifies circular economy criterias guidelines involved from the design & manufacturing to end of the equipment lifecycle applicable in OPEN RAN network equipment, such as: O-CU, O-DU and O-RU, with the intention of creating common aspects and indicators that are necessary to analyze the degree of maturity of the circular economy by network equipment. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +[i.1] ITU-T L.1023 2.0/August 2023: "Assessment method for circularity performance scoring". + +[i.2] GSMA /March 2022: "Strategy Paper for Circular Economy: Network equipment". + +[i.3] NGMN 1.0/July 2021: " Green Future Networks. Network Equipment Eco-Design and End to End Service Footprint". + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +**Circular economy** [ITU-T L.1020]: A circular economy is restorative and regenerative by design, and aims to keep products, components, and materials at their highest utility and value at all times while reducing waste streams. A concept that distinguishes between technical and biological cycles, the circular economy is a continuous, positive development cycle. It preserves and enhances natural capital, optimises resource yields, and minimises system risks by managing finite stocks and renewable flows, while reducing waste streams. + +**ICT goods** [b-ITU-T L.1410]: Tangible goods deriving from or making use of technologies devoted to or concerned with: + +- the acquisition, storage, manipulation (including transformation), management, movement, control, display, switching, interchange, transmission or reception of a diversity of data; +- the development and use of the hardware, software, and procedures associated with this delivery; and +- the representation, transfer, interpretation, and processing of data among persons, places, and machine + +**O-CU:** O-RAN Central Unit [O-RAN.WG1.Use-Cases-Detailed-Specification-R003-v11.00]: a logical node hosting O-CU-CP and O-CU-UPO-DU: O-RAN Distributed Unit: a logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. + +**O-DU:** O-RAN Distributed Unit [O-RAN.WG1.Use-Cases-Detailed-Specification-R003-v11.00]: a Logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. + +**O-RU:** O-RAN Radio Unit [O-RAN.WG1.Use-Cases-Detailed-Specification-R003-v11.00]: a logical node hosting Low-PHY layer and RF processing based on a lower layer functional split. This is similar to 3GPP's "TRP" or "RRH" but more specific in including the Low-PHY layer (FFT/iFFT, PRACH extraction) + +**RAN** [O-RAN.WG1.Use-Cases-Detailed-Specification-R003-v11.00]: Generally referred as Radio Access Network. In terms of this document, any component below near-RT RIC per O-RAN architecture, including O-CU/O-DU/O-RU + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the [following] abbreviations [given in i.1 and the following] apply: + +| | | +|------|------------------------------------------| +| CE | Circular Economy | +| ICT | Information and communication technology | +| NE | Network equipment | +| O-CU | O-RAN Central Unit | + +| | | +|------|--------------------------------------------------------------------| +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| PD | Product durability | +| RAN | Radio Access Network | +| 3Rue | Ability to Recycle, Repair, Reuse, and Upgrade, Equipment level | +| 3Rum | Ability to Recycle, Repair, Reuse, and Upgrade, Manufacturer level | + +# 4 Circular economy on network equipment + +Based on ITU-T L.1023 recommendation, there is a three-step methodology to identify an information and communication technology (ICT) good's circularity in three dimensions via three circularity aspects: first, the ICT good durability, second, the ICT good ability to be recycled, repaired, reused and upgraded; and third, the manufacturers ability to recycle, repair, reuse and upgrade the ICT good put into the market. The three aspects are then divided into indicators for circular product design. + +In this document the circularity indicators are then assessed at three levels, applicability identification on network equipment (O-CU, O-DU and O-RU), how well circularity has been achieved and priority level according to the effect (for customer, environment etc) of the indicator at hand. + +Table 1 – Circularity Aspects – contains a list of circular principles that put all the indicators into different aspects. The description of each aspect is as follows: + +1. **Product durability (PD):** It included indicators related to promoting the life span and durability of products by adapting their design and upgrading software to a new version and service support by ensuring the product can be used for as long as possible by the first user or subsequent users. +2. **Ability to recycle, repair, reuse, upgrade (3Rue) – equipment level:** It includes indicators related to the product's structure and access to its priority parts for repair, connecting, systems to facilitate disassembly and reassembly, spare parts, diagnostic and information availability. It relates to: + - a. Possibilities to refurbish the ICT good; + - b. Possibilities to reuse product parts and components within the ICT good (after first use) in refurbishment of similar or other ICT goods; + - c. Facilitate the identification, separation and recycling of materials. Addresses separate collection of products for better recycling and development of designated recycling technologies. +3. **Ability to recycle, repair, reuse, upgrade (3Rum) – manufacturer level:** It includes indicators related to the manufacturer ability (on company level) to facilitate recycling, repair, reuse, and upgrade. These requirements are not directly connected to the equipment, but to the infrastructure and support to be developed or supported by the manufacturer. It relates to: + - a. Availability of service support in terms of information, infrastructure, and spare parts. + +**Table 4-1 Circularity aspects and indicators applicable on network equipment** + +| Product Durability | Recycle, repair, reuse, upgrade
(Equipment level) | Recycle, repair, reuse, upgrade
(Manufacturer level) | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +|
  • • Software and data support
  • • Scratch resistance
  • • Maintenance support
  • • Robustness
|
  • • Fasteners and connectors
  • • Diagnostic support
  • • Material recycling compatibility - Plastic parts
  • • Material recycling compatibility - Metal parts
  • • Recycled/renewable plastics
  • • Recycled metals
  • • Material identification
  • • Hazardous substances (Bromine and Chlorine)
  • • Critical raw materials
  • • Packaging recycling
  • • Technical performance product mass-based material efficiency
|
  • • Service offered by manufacturer
  • • Spare parts distribution
  • • Spare parts availability
  • • Disassembly information
  • • Collection and recycling programmes
  • • Environmental footprint assessment knowledge publically available
| + +In terms of network equipment circularity aspects and indicators and based on the latest publication of ITU-T L.1023 recommendation, two indicators such as: Battery for portable ICT goods and Data security have been excluded on the table above as they are not applicable on network equipment. + +In summary, each group contains a set of indicators that directly address the group's topic. The proposed table is in principle unlimited regarding the number of groups and indicators. For example, new indicators for scratch resistance for example for metals, glass, etc. can be added with their respective circularity contribution scenarios. Also new groups can be added accordingly. + +Following the second level of assessment of this document, below is described definition and contribution cases to circular economy of each indicator per aspect: + +## 1. Product durability + +**1.1. Software and data support:** Availability of software and firmware updates & upgrades (according to EN 45554). + +- The most contributing variable to the circularity of the equipment: Software and firmware updates & upgrades availability can be categorized as long-term (class A, i.e., for a duration of time that reflects the expected maximum useful life of the product, cf. EN 45554). +- Does not contribute to the circular economy of the equipment: No information on duration of availability (class D, cf. EN 45554) is provided on software and firmware updates & upgrades availability. + +**1.2. Scratch resistance:** Resistance of housing parts subject to be scratched (resistance regarding ASTM D3363 – 05 (2011) e2 standard.) + +- The most contributing variable to the circularity of the equipment: Plastic scratch resistance equal or greater than 2H. +- Does not contribute to the circular economy of the equipment: Plastic scratch resistance lower or equal to B. + +**1.3. Maintenance support:** Availability of consumables, wear-out parts expected to be replaced periodically and availability of maintenance infrastructure (according to EN 45554). + +- The most contributing variable to the circularity of the equipment: Consumables and wear-out parts expected to be replaced periodically can be categorized as publicly available (class A in EN 45554) or as available to independent maintenance service providers (class B in EN 45554). +- Does not contribute to the circular economy of the equipment: Consumables and wear-out parts expected to be replaced periodically can be categorized as not available (class E in EN 45554). No maintenance infrastructure are offered by manufacturer. + +**1.4. Robustness:** Refers to the ability of the equipment to tolerate or resist perturbations that may affect its functional body. If the equipment is robust, it has greater durability and is therefore better from a circular economy point of view. + +- The most contributing variable to the circularity of the equipment: The product's design features have better characteristics than the minimum requirements for the environmental class in which the product is intended to be used and comply to the enhanced requirements (Example: a product intended to be used in non-weather protected location and satisfies the requirements of class 4.1E (extended severity level) of [b-EN 300 019-1-4] instead of class 4.1 (minimum severity level) and complies to the enhanced requirements of ITU-T K.20/21/45). +- Does not contribute to the circular economy of the equipment: The product's design features characteristics do not comply to several of the minimum requirements for the environmental class in which the product is intended to be used. + +## 2. Recycle, repair, reuse, upgrade – Equipment level + +**2.1. Fasteners and connectors:** Fasteners, connectors and tools used to disassemble parts that are likely to need replacement during the expected lifetime of the product are reusable/removable per EN 45554. + +- The most contributing variable to the circularity of the equipment: Fasteners and connectors can be categorized as reusable (class A) and using no tools, basic tools or product specific tools (classes A-C as defined in EN 45554). +- Does not contribute to the circular economy of the equipment: Fasteners and connectors can be categorized as neither removable nor reusable (class C). + +**2.2. Diagnostic support:** Facilitate the identification of problems or defects. Relates to the type of interface available and how intuitive it is for fault detection, parameter reset or default upgrade. An accessible diagnostic and reset interface facilitate further repair, reuse and upgrade. Diagnostic support classification by necessary interface. + +- The most contributing variable to the circularity of the equipment: Interface can be categorized as an intuitive interface (Class A) - cf. EN 45554. +- Does not contribute to the circular economy of the equipment: Diagnostic is not possible with any type of interface (Class E) - cf. EN 45554. + +**2.3. Material recycling compatibility - Plastic parts:** Materials compatibility for joint recycling. + +- The most contributing variable to the circularity of the equipment: All of the following requirements shall be fulfilled; + +- a) Plastic parts >25g do not contain metal inlets or fasteners that are molded, heat or ultrasonically inserted or glued-in and cannot be separated by breaking off from the plastic part or with commonly available tools. +- b) Plastic parts >100g do not have an adhesive, coating, paint or finish that is not compatible with recycled. NOTE: Plastic parts with >25% post-consumer recycled content and printed-circuit boards are exempt. Requirement does not apply to parts where such measures are required for safety, legal or technical requirements. +- c) Plastic parts >25g are comprised of a single resin or combination of resins compatible for recycling and are separable by hand or with commonly available tools from other plastic parts >25g and not compatible for joint recycling. NOTE: Printed circuit boards, wires and cables, connectors, electronic, optical, acoustic, ESD and EMI components are excluded. +- Does not contribute to the circular economy of the equipment: None of the requirements specified is fulfilled. + +## 2.4. Material recycling compatibility - Metal parts: Materials compatibility for joint recycling. + +- The most contributing variable to the circularity of the equipment: All of the following requirements shall be fulfilled. + - a) In metal parts with weight > 25 g, metals are kept separable for easy recycling, particularly the materials intended for different end-of-life treatment. + - b) Data on used alloys is available. + - c) Metal parts with weight > 25 g do not have such adhesive, coating, paint, or finish that is not compatible with recycling. +- Does not contribute to the circular economy of the equipment: None of the requirements specified is fulfilled. + +## 2.5. Recycled/renewable plastics: Use of pre- or post-consumer recycled plastics. NOTE: Refers to plastics used in the ICT good itself. + +- The most contributing variable to the circularity of the equipment: Total content of recycled and biobased plastics 75-100%. +- The less contributing variable to the circularity of the equipment: Total content of recycled and biobased plastics 0-25%. + +## 2.6. Recycled metals: Use of recycled metals. + +- The most contributing variable to the circularity of the equipment: Combined total recycled metals content in at least two predominant metals by mass is 75-100%. +- Does not contribute to the circular economy of the equipment: Combined total recycled metals content in at least two predominant metals by mass is 0-25%. + +## 2.7. Material identification: Identification and marking of the materials contained in the equipment. The identification and marking of materials facilitate the subsequent recycling of the equipment. Materials identification according to ISO 11469. + +- The most contributing variable to the circularity of the equipment: Markings to identify base materials as per ISO 11469, ISO 1043-1 (plastics), ISO 1629 (rubbers) ISO 18064 (thermoplastic elastomers), as well as fillers and reinforcing materials (ISO 1043-2), plasticizers (ISO 1043-3) and flame retardants (ISO 1043-4) +- Does not contribute to the circular economy of the equipment: No markings to identify materials on any part. + +## **2.8. Hazardous substances (Bromine and Chlorine):** Reduction of bromine and chlorine in plastic parts (The flame retardant used in plastic parts may contain these hazardous substances). + +- The most contributing variable to the circularity of the equipment: Each plastic part in the product exceeding 0.5 g shall not contain greater than 1000 ppm chlorine or greater than 1000 ppm bromine at the homogeneous level [b-IEEE1680]. Test methods such as IEC 62321-3-1 and 62321-3-2 are recommended. [b-IEEE1680]. NOTE: Parts which exceed 25% post-consumer recycled content may contain a maximum of 5000 ppm chlorine and a maximum of 5000 ppm bromine [b-IEEE1680]. Power cords - in jurisdictions where PVC-free power cords have not been approved by safety agencies for use in the product - are exempted. [b-IEEE1680]. +- Does not contribute to the circular economy of the equipment: The bromine and chlorine based substances content is unknown. + +## **2.9. Critical Raw Materials:** Declaration of Critical Raw Materials Content. NOTE: CRMs are different for each region. Examples of defined CRM include L.1100 and the list of CRM for the EU [b-EU-CRM]. Each product has to choose the appropriate CRM list. + +- The most contributing variable to the circularity of the equipment: Based on the CRM content assessment, the location of the CRM in the ICT good is available to improve recyclability. +- Does not contribute to the circular economy of the equipment: The CRM content is unknown. + +## **2.10. Packaging recycling:** Material recycling aspects included in the primary packaging. + +- The most contributing variable to the circularity of the equipment: All the aspects of material efficiency are considered for the packaging, by fulfilling all of the following five requirements: + - a) Elimination of elemental chlorine as a bleaching agent used to bleach virgin or recovered fibers subsequently used in product packaging. + - b) Elimination of the use of expanded polystyrene in product packaging. + - c) Packaging is designed in a way that it allows reuse, recycling or recovery. + - d) Sum of the concentrations of intentionally added lead, cadmium, mercury and hexavalent chromium present in primary packaging shall not exceed 100 ppm by weight. + - e) Minimum used 30% recycled content by mass of plastic and fibre-based materials. +- Does not contribute to the circular economy of the equipment: None of the requirements for packaging material recycling are fulfilled. + +## **2.11. Technical performance product mass-based materials efficiency:** Technical performance per product mass. + +- The most contributing variable to the circularity of the equipment: Technical performance per product mass used improved > 15% in between product at hand and previous corresponding product model. +- Does not contribute to the circular economy of the equipment: Technical performance per product mass not improved in between product at hand and previous corresponding product model. + +## 3. Ability to Recycle, Repair, Reuse, upgrade - Manufacturer level + +**3.1. Service offered by manufacturer:** Duration of Repair, Reuse, upgrade services (according to EN 45554). + +- The most contributing variable to the circularity of the equipment: Repair, Reuse and upgrade service availability can be categorized as long-term (class A). NOTE: Expected durability is the time a customer (the user of the ICT good) can expect the product to last. +- Does not contribute to the circular economy of the equipment: No Repair, Reuse and upgrade service availability is offered. + +**3.2. Spare parts distribution:** Availability of spare parts to different categories of persons/ organisations to facilitate equipment repairability (according to EN 45554). + +- The most contributing variable to the circularity of the equipment: Spare parts are publicly available or available to independent repair service providers (Class A and Class B, as defined in EN 45554). +- Does not contribute to the circular economy of the equipment: Spare parts are not available (Class E, as defined in EN 45554). + +**3.3. Spare parts availability:** Duration of spare parts availability (according to EN 45554). The longer the availability of spare parts, the greater the circularity. + +- The most contributing variable to the circularity of the equipment: Spare parts availability can be categorized as long-term (class A, i.e., a repair, re-use or upgrade process, for which the required spare part(s) is/are available for a duration of time that reflects the expected durability of the product category, cf. EN 45554) +- Does not contribute to the circular economy of the equipment: No information on duration of availability is provided for spare parts (class D, i.e., repair, re-use or upgrade process, for which the required spare part(s) is/are available at the time of sale, but for which the duration of availability cannot be determined, cf. EN 45554). + +**3.4. Disassembly information:** Classification of information availability by comprehensiveness (according to EN 45554). + +- The most contributing variable to the circularity of the equipment: Information is publicly available (class A, i.e., repair, re-use or upgrade process, for which the relevant information is available to all interested parties, cf. EN 45554). +- Does not contribute to the circular economy of the equipment: Information is available to the manufacturer only (class D, i.e., repair, re-use or upgrade process, for which the relevant information is available to the product manufacturer, cf. EN 45554). + +**3.5. Collection and recycling programmes:** Designated collection and recycling programs. + +- The most contributing variable to the circularity of the equipment: A designated collection program for refurbish, remanufacturing, repair and a designated selective, recycling program for specific parts of ICT goods (e.g., specific recycling process able to recover Germanium from optical fiber, Tantalum from Tantalum capacitors or Indium from LCD/OLED displays, etc.) is available. +- Does not contribute to the circular economy of the equipment: Neither designated collection nor designated recycling program is available. + +**3.6. Environmental footprint assessment knowledge publically available:** Knowledge on the equipment environmental footprint. + +- The most contributing variable to the circularity of the equipment: An [b-ISO 14040] / [b-ISO 14044] or [b-ITU-T L.1410] compliant life cycle assessment (LCA) has been carried out on the ICT good and the results are made available on demand. +- Does not contribute to the circular economy of the equipment: Neither an environmental footprint assessment have been done on the ICT good, nor an environmental footprint assessment on a similar type of equipment are made available on demand. + +As a last step of assessment of this document, and part of the third level, below is described priority level definition and will be detailed in the following sub-chapter by each network equipment included in the scope of this document. + +Table 2 – Priority level – consist of a level of relevance of each circularity indicator based on relevance characteristics + +**Table 4-2 Priority level definition based on contribution effect to circular economy** + +| Level | Priority Level | Description | +|-------|----------------|----------------------------------------------------------------------------------------| +| 1 | Very HIGH | Indicator with a very high positive effect to the contribution of the circular economy | +| 2 | HIGH | Indicator with a high positive effect to the contribution of the circular economy | +| 3 | LOW | Indicator with a low positive effect to the contribution of the circular economy | +| 4 | Very LOW | Indicator with a very low positive effect to the contribution of the circular economy | + +## 4.1 O-CU/O-DU + +**Table 4.1-1 O-CU/O-DU priority definition based on circularity economy effect** + +| Circularity aspects | Circularity indicator | Priority | +|---------------------------------------------------|---------------------------|----------| +| Product Durability | Software and data support | 1 | +| | Scratch resistance | 4 | +| | Maintenance support | 1 | +| | Robustness | 3 | +| Recycle, repair, reuse, upgrade – Equipment level | Fasteners and connectors | 1 | +| | Diagnostic support | 2 | + +| | | | +|---------------------------------------------------------|-------------------------------------------------------------------|---| +| | Material recycling compatibility - Plastic parts | 2 | +| | Material recycling compatibility - Metal parts | 1 | +| | Recycled/renewable plastics | 2 | +| | Recycled metals | 1 | +| | Material identification | 1 | +| | Hazardous substances (Bromine and Chlorine) | 1 | +| | Critical Raw Materials | 1 | +| | Packaging recycling | 2 | +| | Technical performance product mass-based material efficiency | 1 | +| Recycle, repair, reuse, upgrade
– Manufacturer level | Service offered by manufacturer | 1 | +| | Spare parts distribution | 2 | +| | Spare parts availability | 1 | +| | Disassembly information | 1 | +| | Collection and recycling programmes | 2 | +| | Environmental footprint assessment knowledge publically available | 1 | + +## 4.2 O-RU + +**Table 4.2-1 O-RU priority definition based on circularity economy effect** + +| Circularity aspects | Circularity indicator | Priority | +|------------------------------------------------------|--------------------------------------------------|----------| +| Product Durability | Software and data support | 1 | +| | Scratch resistance | 4 | +| | Maintenance support | 1 | +| | Robustness | 1 | +| Recycle, repair, reuse, upgrade
– Equipment level | Fasteners and connectors | 1 | +| | Diagnostic support | 2 | +| | Material recycling compatibility - Plastic parts | 2 | +| | Material recycling compatibility - Metal parts | 1 | + +| | | | +|---------------------------------------------------------|-------------------------------------------------------------------|---| +| | Recycled/renewable plastics | 2 | +| | Recycled metals | 1 | +| | Material identification | 1 | +| | Hazardous substances (Bromine and Chlorine) | 1 | +| | Critical Raw Materials | 1 | +| | Packaging recycling | 2 | +| | Technical performance product mass-based material efficiency | 1 | +| Recycle, repair, reuse, upgrade
– Manufacturer level | Service offered by manufacturer | 1 | +| | Spare parts distribution | 2 | +| | Spare parts availability | 1 | +| | Disassembly information | 1 | +| | Collection and recycling programmes | 2 | +| | Environmental footprint assessment knowledge publically available | 1 | + +# Annex A (informative): Reduction of environmental impact through circular economy + +## A.1 Equipment lifecycle aspects to consider + +![Diagram showing the equipment lifecycle stages: Design & Manufacturing, Use, Reuse, and End of life, with a feedback loop from End of life back to Design & Manufacturing.](83557251ef78793fdb5e0084561b5391_img.jpg) + +**Reduction of environmental impact through circular economy** + +Equipment lifecycle aspects to consider... + +``` + +graph LR + DM[Design & Manufacturing] --> U[Use] + U --> R[Reuse] + R --> EL[End of life] + EL --> DM + +``` + +**Design & Manufacturing** + +Design with circularity criteria: + +- Durability +- Material resistance +- Repairability +- Upgradability +- Content of recycled material +- Low resource and energy consumption +- Manufacturing environmental standards (without pollution) +- Eco-friendly packaging + +**Use** + +Extend equipment operational lifespan: + +- Available and affordable repair services +- Spare parts replacement availability +- Avoidance of planned obsolescence +- Sharing equipment and infrastructure to increase usage +- Upgradable software and firmware +- Equipment maintenance + +**Reuse** + +Repurpose equipment to prevent it from becoming waste: + +- Refurbishment +- Remanufacture +- Reverse logistics +- Facilitate the purchase and sale of second-hand equipment (transferable licences, warranties, maintenance and technical support when ownership of equipment changes) + +**End of life** + +Closing the loop: + +- Recycling compatible materials +- Easy disassembly +- Considering waste as a resource through recycling (sale of recoverable materials) + +Diagram showing the equipment lifecycle stages: Design & Manufacturing, Use, Reuse, and End of life, with a feedback loop from End of life back to Design & Manufacturing. + +**Figure A.1-1: Reduction of environmental impact through circular economy** + +# --- Revision history + +| Date | Revision | Description | +|------------|----------|---------------------------------------------------------------------------------------------------| +| 2023.12.11 | 01.00 | First version of circular economy guidelines on network equipment based on ITU-T L.1023 (08/2023) | + +## --- History + +| Date | Revision | Description | +|------|----------|-------------| +| | | | +| | | | +| | | | +| | | | \ No newline at end of file diff --git a/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7b84e262d2fc7e0b59b4101053a42526958b946a --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e7bdaaf5aacb655dae815886fc7e68b08115ae4458078ccf72b022c81a0a12c +size 4142 diff --git a/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..44e4ca1e706fffc218594e75b7fbdfaeee43149d --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ba36991bdae993881d357810ae680e8b2718eeb75c0831521a0cdc2d6e038f2 +size 4147 diff --git a/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/a91f4fb2157b682a3295836b8b8e2d5c_img.jpg b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/a91f4fb2157b682a3295836b8b8e2d5c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1624885035e55cf6001c2009d780b95cc6680b68 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/a91f4fb2157b682a3295836b8b8e2d5c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c92f80674dbfe05e46caab62e5fda53b55f3ffd6f04aadb315c070b5286ef4d9 +size 4189 diff --git a/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/d11c8c6682346664fa09e6c8a7574c71_img.jpg b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/d11c8c6682346664fa09e6c8a7574c71_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2da5a2df90c643e5879a90624755d7c04e88962c --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/d11c8c6682346664fa09e6c8a7574c71_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:135a376611b8f240570734b1172f79a3f3fcb4cb3afcf507e1b3f44992a2b692 +size 3839 diff --git a/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/eed97810b73ce2008906a0918abed322_img.jpg b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/eed97810b73ce2008906a0918abed322_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e9d056186f91071754a1bd66cc5b0f58f9cdcd1d --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/eed97810b73ce2008906a0918abed322_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a6feea577002af775f92c1c073ef8e278549447e23549760a568e59d2a4c42d6 +size 4142 diff --git a/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/fa49186bb622c095765fd8ddc772729a_img.jpg b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/fa49186bb622c095765fd8ddc772729a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1af4baa9997cb759fd2b6a6708563bc34a058214 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/fa49186bb622c095765fd8ddc772729a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b7de6899a3e71e7d5cb96e3cf5688867518bde70faaa5a1d8d15817d1aa6097 +size 4042 diff --git a/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/raw.md b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..f15a99df4297c7cecbfa731a33ac50cbb91d111d --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00/raw.md @@ -0,0 +1,616 @@ + + +# **O-RAN ALLIANCE Test and Integration Focus Group****Criteria and Guidelines of Open Testing and Integration Centre** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +--- + +| | | | | +|----|------------------------------------------------------------------|-------------------------------------|----| +| 1 | Contents | | | +| 2 | Foreword..... | | 2 | +| 3 | Modal verbs terminology ..... | | 2 | +| 4 | 1 Scope..... | | 3 | +| 5 | 2 References..... | | 3 | +| 6 | 2.1 Normative references..... | | 3 | +| 7 | 2.2 Informative references..... | | 4 | +| 8 | 3 Definition of terms, symbols and abbreviations..... | | 4 | +| 9 | 3.1 Terms..... | | 4 | +| 10 | 3.2 Symbols..... | | 5 | +| 11 | 3.3 Abbreviations..... | | 5 | +| 12 | 4 Overview of OTIC ..... | | 6 | +| 13 | 5 General Requirements of OTIC ..... | | 7 | +| 14 | 5.1 Participants and roles in OTIC..... | | 7 | +| 15 | 5.1.1 Host..... | | 7 | +| 16 | 5.1.2 Partner..... | | 8 | +| 17 | 5.1.3 Client..... | | 8 | +| 18 | 5.1.4 Observer..... | | 8 | +| 19 | 5.2 OTIC Physical Lab Architecture and Layout ..... | | 9 | +| 20 | 5.3 Basic Guidelines for OTIC Agreements..... | | 9 | +| 21 | 6 Application and Qualification Processes..... | | 10 | +| 22 | 6.1 Application for OTIC Qualification..... | | 10 | +| 23 | 6.2 OTIC Application Reviewing and Evaluation ..... | | 11 | +| 24 | 6.3 OTIC Application Approval ..... | | 11 | +| 25 | 6.4 OTIC Catalogue..... | | 12 | +| 26 | 6.5 Complaints and Disqualification..... | | 12 | +| 27 | Annex A (normative): OTIC application form..... | | 14 | +| 28 | Annex B (informative): Guidelines on OTIC application form ..... | | 20 | +| 29 | Annex C (normative): Hosting agreement..... | | 21 | +| 30 | Revision history..... | | 25 | +| 31 | History ..... | Error! Bookmark not defined. | | + +--- + +# 32 Foreword + +33 This Process Document has been produced by O-RAN ALLIANCE. + +--- + +# 34 Modal verbs terminology + +35 In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", +36 "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal +37 forms for the expression of provisions). + +"must" and "must not" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document describes the essential criteria and guidelines (guiding principles) from process, organization, space and technical perspective on the qualified Open Testing and Integration Centre (OTIC). + +The conformance and interoperability certification/validation/badging processes will be described in a separate set of documents (e.g. [1]), incl. the definition on who can and how to issue O-RAN certificate or badge. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN.TIFG.Cert-Badge.0-v05.00: O-RAN ALLIANCE Test and Integration Focus Group, Certification and Badging Processes and Procedures, Version 05.00, October 2022" +- [2] O-RAN.WG1.O-RAN-Architecture-Description-v07.00: O-RAN ALLIANCE WG1, O-RAN Architecture Description, Version 7.0, October 2022 +- [3] O-RAN.TSC.WORKPROC-v03.00: "O-RAN Working Procedures" +- [4] O-RAN ALLIANCE Constitution, version 27-06-2018 , available at [www.o-ran.org/membership-info](http://www.o-ran.org/membership-info) + +1 + +# 2 2.2 Informative references + +3 References are either specific (identified by date of publication and/or edition number or version number) +4 or non-specific. For specific references, only the cited version applies. For non-specific references, the latest +5 version of the referenced document (including any amendments) applies. + +6 NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN +7 cannot guarantee their long-term validity. + +8 The following referenced documents are not necessary for the application of the present document, but +9 they assist the user with regard to a particular subject area. + +10 + +# --- 11 3 Definition of terms, symbols and abbreviations + +# 12 3.1 Terms + +13 For the purposes of the present document, the following terms apply: + +14 **Affiliate:** the definition is given in [4]. + +15 **Blueprint:** is the set of inputs which is used to describe a specific O-RAN deployment from several aspects. +16 These aspects include the specification of the O-RAN deployment at the system level (e.g. architecture, +17 performance metrics) as well as subsystem level and the interfaces between the specified subsystems. This +18 would then allow definition and documentation of the testing methodology and the test cases using the +19 blueprint specification. + +20 **Client:** is a participant in OTIC who provides its O-RAN equipment, components and/or services for the testing +21 in OTIC. + +22 **Host:** is a founder and main sponsor of Open Testing and Integration Centre (OTIC). Only O-RAN Member +23 (including the affiliates [4]) or non-vendor O-RAN Participants (including the affiliates [4]) may become a host. +24 Host is mandatory entity in OTIC. + +25 **IOT profile:** specifies a specific selection of parameters, optional features, default values and ranges of +26 configurable attributes and mechanisms from O-RAN subsystem interface specification(s) that shall be +27 supported and used in order to guarantee interoperability between implementations from different vendors. + +28 **Observer:** is a participant in OTIC who is allowed to observe the testing activities in OTIC for a limited period +29 and/or a limited purpose. + +30 **OTIC:** is a qualified Open Testing and Integration Centre meeting the relevant subset of criteria and guidelines +31 mentioned in the present document. + +32 **O-RAN Academic Contributor:** the definition is given in [3]. + +33 **O-RAN Contributor:** the definition is given in [3]. + +34 **O-RAN Entity:** the definition is given in [3]. + +- 1 **O-RAN Member:** the definition is given in [3]. +- 2 **O-RAN Participant:** the definition is given in [3]. +- 3 **Partner:** is a participant in OTIC who can provide, maintain and/or operate test and measurement equipment +4 and tools, can provide space and services, can design, set-up, conduct and evaluate the testing activities on +5 behalf of host. +- 6 **Testing:** any activity involving testing of O-RAN equipment, e.g. plugfest, demo, lab trial, field trial. + +# 7 3.2 Symbols + +8 For the purposes of the present document, the following symbols apply: + +9 + +# 10 3.3 Abbreviations + +11 For the purposes of the present document, the following abbreviations apply: + +| | | | +|----|---------|-------------------------------------------------| +| 12 | IOT | Interoperability | +| 13 | IUT | Interface under Test | +| 14 | O-CU-CP | O-RAN Central Unit – Control Plane | +| 15 | O-CU-UP | O-RAN Central Unit – User Plane | +| 16 | O-DU | O-RAN Distributed Unit | +| 17 | O-RU | O-RAN Radio Unit | +| 18 | OTIC | Open Testing and Integration Centre | +| 19 | PoC | Proof of Concept | +| 20 | RIC | RAN Intelligent Controller | +| 21 | TIFG | O-RAN ALLIANCE Test and Integration Focus Group | +| 22 | TSC | O-RAN ALLIANCE Technical Steering Committee | +| 23 | | | + +# 4 Overview of OTIC + +The Open Testing and Integration Centre (OTIC) provides a collaborative, open, and impartial working environment; however, the intellectual property of participants in OTIC must be protected in this environment as well. + +The environment meeting all of the criteria and guidelines from this document may be qualified as OTIC and may be named as “Open Testing and Integration Centre (OTIC)”. OTIC may or may not have its own legal incorporation. OTIC is an activity outside O-RAN ALLIANCE. + +Multiple OTICs may exist in different regions around the world. Each OTIC may focus on different O-RAN functions [2] (such as Near-RT RIC, O-CU-CP and O-CU-UP, O-DU, O-RU), interfaces [2] (such as Open Fronthaul, E2, O1, O2, A1), blueprints, IOT profiles, etc. The testing results, experiences, best practices, knowledge, lesson-learned, adopted processes, etc. are assumed to be shared among the OTICs in order to reduce the overall costs and resources and coordinate the efforts. The learning and experiences may also be published and shared outside the O-RAN community with specified level of confidentiality. The Open Testing and Integration Centre is proposed as vendor-independent1, open and qualified physical space in order to, among others (not everything must be included in the scope of work of a particular OTIC): + +- a) Support of wide adoption of O-RAN specifications and promote the openness of O-RAN ecosystem via demos, community events (e.g. speaker sessions, workshops, tutorials), lab and field trials, etc. +- b) Demonstrate implementations and solutions based on O-RAN specifications via plugfests and proofs of concept “PoCs”. +- c) Test and verify the conformity of RAN equipment with O-RAN interface specifications, based on O-RAN conformance test specifications. +- d) Test and verify the interoperability of RAN equipment from different vendors (or the same vendor) using O-RAN interface specifications, based on O-RAN interoperability test specifications. +- e) Foster and develop the integrator’s technical capabilities via workshops, tutorials, etc. +- f) Conduct functional as well as performance (load, capacity) tests of both end-to-end systems as well as sub-systems. +- g) Give O-RAN (in particular O-RAN workgroups, O-RAN contributors) feedback about the experiences made with O-RAN specifications during the testing activities (i.e. implementation driven specification). + +The coordination (in terms of considered focus areas, test scenarios, operators’ specific requirements, plugfests) among worldwide OTICs is required to avoid fragmentation and repeating the same functional as well as performance tests (with the same vendors) multiple times. The services offered by OTICs should be complementary rather than competitive. + +The O-RAN ALLIANCE in cooperation with TIFG (O-RAN ALLIANCE Test and Integration Focus Group) is the governing body to resolve any un-clarity, inconsistency and ambiguity in the present document, as well as any conflict and complaint which cannot be resolved internally inside OTIC. + +--- + +1 Vendors include all commercial suppliers of equipment and tools, including test and measurement companies. + +# 5 General Requirements of OTIC + +## 5.1 Participants and roles in OTIC + +The following roles with relations and responsibilities are defined in Open Testing and Integration Centre (OTIC): + +- a) Host +- b) Partner +- c) Client +- d) Observer + +### 5.1.1 Host + +- a) Host is a founder, main contact (designated multi-host representative in case of co-hosted OTIC) and main sponsor of OTIC. The financial flows inside the OTIC are controlled and managed by the host itself. Host is also an entity which coordinates and is fully responsible for all the activities in OTIC. +- b) Host shall be an O-RAN Member [3] (i.e. mobile operator, including the affiliates [4]) or an O-RAN Participants [3] (i.e. O-RAN Contributor or O-RAN Academic Contributor, including the affiliates [4]); in order to ensure a high level of credibility, confidentiality, the O-RAN Participant shall demonstrate vendor-independence2. For example, a third-party authorized test laboratory (an open lab) may also host OTIC, but it shall become O-RAN Participant first. Note that only O-RAN Entities may present the results, proposals, etc. at O-RAN ALLIANCE meetings, and upload the results and reports to O-RAN ALLIANCE wiki and other shared folders. +- c) OTIC may be hosted by one or more hosts (co-hosted OTIC). In this case a designated multi-host representative will be designated as main OTIC contact among the involved hosts. +- d) Host provides the space (test rooms, server rooms) for conducting of the tests and hosting the events (incl. IOT and conformance testing, plugfest, PoC, demo), network connectivity, and test/measurement equipment, tools and services. These can be fully or partially provided by the host itself or by the contracted partner(s), but the host assumes responsibility for meeting the required criteria, conditions, and guidelines. +- e) Host guarantees the openness and fairness to any client who has interest in testing its equipment in OTIC. It means OTIC is available and open for all clients, and any client may not be disqualified from testing in OTIC without cause. All clients shall be handled equally. +- f) Host guarantees the credibility, confidentiality, openness and vendor-independence2 of OTIC. Host also guarantees that the agreed test procedures are properly followed, and the results are produced in agreed format and with certain level of quality and confidentiality. +- g) Host enters into agreements (e.g. participant agreement, testing agreement) with all other participants in OTIC. The agreement shall be in compliance with the criteria and requirements stated in the present document. +- h) Host shall take all necessary steps (e.g. participant's agreement, testing agreement, isolated space) to work towards protecting the intellectual property each participant in OTIC in a mutually collaborative environment; however, OTIC participants shall recognize that it may not be possible to safeguard intellectual property in all situations, e.g. outdoor equipment. + +2 Vendors include all commercial suppliers of equipment and tools, including test and measurement companies. + +- i) Host shall take necessary steps to ensure that the used test and measurement equipment and tools are properly calibrated and ready to use. +- j) Host allows the detailed results, blueprints, interface profiles, experiences, best practices, knowledges, lesson-learned, adopted processes, etc. to be shared following the confidentiality levels from the agreements. +- k) Host regularly presents the summary of testing results, experiences, best practices, knowledges, lesson-learned and adopted processes at TIFG meetings (and optionally on request to any other O-RAN meeting). +- l) Host or multi-host designated representative responds to the request for information or testing results from TIFG in a timely manner. +- m) Host acts as a mediator trying to resolve any complaint inside OTIC. The complaint resolution processes (incl. documentation of resolution of complaint) shall be set up in each OTIC. O-RAN ALLIANCE in cooperation with TIFG acts as the governing body in case the complaint might not be resolved by the host(s) inside OTIC. +- n) In the multi-host scenario, O-RAN ALLIANCE and TIFG will only communicate officially with the multi-host designated representative. + +### 5.1.2 Partner + +- a) Partner is any company/organization with or without O-RAN ALLIANCE membership in good standing. +- b) Partner can provide maintain, and/or operate test and measurement equipment and tools (e.g. emulators, log tools, analysers, generators) on behalf of the host on permanent basis or temporary basis per test. +- c) Partner can provide, maintain space (rooms, servers) and services in OTIC on behalf of the host. +- d) Partner can design, set-up, conduct and evaluate the testing activities on behalf of the host, but the host always guarantees that the test procedures are properly followed with certain level of quality and confidentiality (e.g. using a confidentiality agreement signed between host and partner). +- e) All the aforementioned items can be also provided by the host itself, i.e. OTIC can have no contracted partner. + +### 5.1.3 Client + +- a) Client (or customer) is any company/organization with or without O-RAN ALLIANCE membership in good standing producing O-RAN equipment and components which are subsequently provided for the testing in OTIC. +- b) Client can choose any OTIC for the testing of its RAN equipment and components. +- c) The host or delegated partner should sign a testing agreement with the client. +- d) Client is encouraged to leave at least one representative product in the OTIC for a reasonable time period. Leaving more than one product is encouraged, as is replacing outdated products with newer models. + +### 5.1.4 Observer + +- a) Observer (or Visitor) is any company/organization with or without O-RAN ALLIANCE membership in good standing which is allowed to observe the testing activities in OTIC for a limited period and/or a limited purpose. The period and purpose shall be clearly specified and known in advance to all participants in OTIC involved in testing activity. The role is expected to be more related to the O-RAN PlugFest. + +- b) The host guarantees that the confidentiality in OTIC is not violated by the observer (e.g. using a confidentiality agreement signed between host/delegated partner and observer). + +## 5.2 OTIC Physical Lab Architecture and Layout + +The OTIC physical lab is designed to create an open and collaborative environment, but at the same time satisfy IPR protection concerns of all OTIC participants. OTIC is a place where different participating companies are onsite collaborating, and where multiple different testing activities can be hosted at the same time. Therefore, the space layout, architecture and network setups shall be flexible and ensure restricted access to specific components only to specific participants engaged in specific testing activity. + +A logical and physical separation between OTIC and the rest of facilities (e.g. host's own internal lab(s)) shall be provided and ensured in order to minimize any security risk. The OTIC environment should be presented as an OTIC resource. + +Every testing activity shall be assigned a separated work area with restricted access (e.g. a badging access) only to participants engaged in that testing activity. The work area shall be equipped with working desks and secure connections to the server room(s) with server racks. The size of specified work area is related to the number of engaged participants and complexity of the testing activity. + +The server room(s) shall be separated from the work area. The restricted access to server room is granted only to participants engaged in the testing activity(ies). The server room might be shared for multiple testing activities but the physical and/or logical separation between servers shall be ensured (e.g. physical servers separated in locked racks, virtual servers logically separated). + +The access to the network and sharing of the resources and equipment should be secured (e.g. using subnets, access lists). + +The host of OTIC is responsible (also, where appropriate, by engaging into specific agreements with any contracted partners) for the security, configuration and maintenance of network (e.g. assignment of subnets, VPNs to each testing activity and participants) as well as for identification and provision of the proper test and measurement equipment and tools within hosted testing activities and supported services and focus areas. The additional equipment and tools, which are not available in OTIC, might be needed for the period of the testing activity. + +Each OTIC is encouraged to have the capability to easily and securely connect to the other OTICs in case different HW or SW components from each individual OTIC need to communicate with each other. + +The vendors may remotely connect their O-RAN functions to the OTIC and run the specified remote testing (e.g. remote testing of A1 interface between Non-RT RIC and Near-RT RIC, or O1 interface between Service Management and Orchestration system and O-RAN functions). This will allow vendors to scale logistic issues. + +The OTIC support of remote connectivity is optional. + +## 5.3 Basic Guidelines for OTIC Agreements + +O-RAN ALLIANCE foresees the following two types of agreements that OTIC will adopt + +- Legal agreement between host and its potential partners, clients or observers + +- Legally binding Hosting agreement between the underlying OTIC (OTIC host(s)) and O-RAN ALLIANCE (see Annex C) + +In general, the host or hosts have the full flexibility and authorization to negotiate and sign legal agreements with its partners, clients and observers. O-RAN ALLIANCE will not interfere in such processes. However, O-RAN ALLIANCE recommends the following main common items to be included in the agreement: + +- Confidentiality +- Openness and fairness +- Rights to share the testing/validation results and other outcomes + +It is required for the underlying OTIC and its host(s) to sign the Hosting agreement with O-RAN ALLIANCE to be qualified as Open Testing and Integration Centre (OTIC), which may cover the following processes and main considerations: + +- Qualification and disqualification process +- Reporting and results sharing process +- Complaint resolution process + +# --- 6 Application and Qualification Processes + +## 6.1 Application for OTIC Qualification + +This section describes OTIC qualification process. The OTIC applicant (i.e. host or designated multi-host representative in case of co-hosted OTIC) needs to send the complete application to *otic@groups.o-ran.org* in order to start OTIC qualification process. The OTIC application can be submitted at any time. The submitted application is received by the O-RAN Office and sent to TIFG for handling the review. The approval process is handled by O-RAN Office. The OTIC application form is defined in Annex A (with the guidelines on how to fill OTIC application form in Annex B), and it contains among others the following information: + +- General information about OTIC, incl. name of OTIC, location (address) and main contacts +- Information about the host(s) and potential partners, if any +- Information about the lab(s), incl. space layout and architecture +- Information about the supported focus area and work scope – supported services and test cases +- OTIC applicant self-declaration confirming that the requirements for qualification have been fulfilled. + +The name of OTIC shall be unique and English name including word “OTIC”. The proposed OTIC name may be revised and harmonized with other OTIC names during the review meeting. It would be also recommended (optional) to use the naming convention (scheme) based on geographic location of OTIC lab(s) and/or hosting company/organization name(s) whenever possible. Please visit for already approved OTIC names. + +The following changes are subject to O-RAN approval. The OTIC needs to send a request for such approval to *otic@groups.o-ran.org*. + +- Changing of name of OTIC +- Changing of host(s) of the OTIC + +## 6.2 OTIC Application Reviewing and Evaluation + +Once the O-RAN Office sends the application to the TIFG, TIFG co-chairs assign each application to a reviewer who is the next in line and who has no relation to the OTIC applicant or OTIC host(s). The applications should be equally distributed to the reviewers. + +The reviewer is selected from the list of reviewers which is maintained by TIFG. The reviewer list is accessible to all O-RAN Entities [3], and it contains information about the reviewers such as name, e-mail address, phone number, company affiliation, and assigned OTIC applications. Any representative of O-RAN Entity can be registered in or deregister from the list of reviewers at his or her own request at any time. The TIFG co-chairs can re-select the assigned reviewer if needed. + +The assigned reviewer checks the application to ensure it is complete and in compliance with the requirements. If needed, the reviewer may request OTIC applicant to provide additional information for any missing or unclear information in the application. The reviewer is designated as the point of contact for all communications with OTIC applicant. The reviewer helps OTIC applicant to complete the application. The reviewer guarantees completeness and compliance of the application. The reviewer does not approve or evaluate the application. + +Once the application is completed, the assigned reviewer needs to inform TIFG co-chairs to schedule a review meeting where OTIC applicant will present and defend the application. If needed, TIFG can also try to coordinate the application with other OTICs in order to avoid fragmentation, overlap, etc. + +If the review meeting does not take place within 2 months of the date when application was submitted, the application may be withdrawn from review process. The applicant can still submit new OTIC application later on. + +The preliminary favourable or unfavourable recommendations should be collected by TIFG co-chairs during the review meeting, and provided to OTIC applicant after the review meeting. The TIFG co-chairs also add the recommendations and summary of the review meeting to OTIC application. OTIC applicant has the rights to provide their statements and any necessary information or correction if the unfavourable recommendation is made. The OTIC applicant statements and corrections are also added to OTIC application. + +It needs to be noted that the OTIC application cannot be approved or rejected by TIFG. + +## 6.3 OTIC Application Approval + +The completed application with TIFG recommendations and with OTIC applicant statements, if provided, shall be sent back to the O-RAN Office for further approvals. The OTIC application is handled as a process document and not as a technical specification. OTIC applicant needs to address any question or inquiry raised during this official approval process. + +After passing O-RAN ALLIANCE approval process, OTIC applicant will be required to sign the **Hosting agreement** with O-RAN ALLIANCE, which is defined in Annex C. The OTIC qualification process is considered completed after the Hosting agreement is signed. + +It needs to be noted that O-RAN ALLIANCE can terminate the Hosting agreement without cause at any time with prior written notice. + +It needs to be also noted that the additional criteria and requirements on conformance and interoperability validation processes (certification, badging, etc.) can be added and described in a separate set of documents (e.g. [1]). + +There may be a future requirement to make a contribution or to pay a license fee to the O-RAN ALLIANCE for the use of their logos (e.g., “O-RAN”, “OTIC”) or fees for O-RAN qualification services in the event that an OTIC collects a fee. + +## 6.4 OTIC Catalogue + +The assigned reviewer will create new record (page) with the information about approved OTIC in the list of OTICs (OTIC catalogue) at O-RAN ALLIANCE wiki and at O-RAN ALLIANCE web site. The reviewer will be also assigned as the initial page administrator in the OTIC catalogue. The list of OTICs is maintained by TIFG (via assigned page administrator), and each **OTIC needs to keep all published information up to date** – any relevant change, which does not require approval (see chapter 6.1 for changes requiring approval), shall be reported to assigned page administrator as soon as possible. The page administrator ensures changes at all relevant places. TIFG co-chairs can re-select the assigned page administrator if needed. + +## 6.5 Complaints and Disqualification + +O-RAN ALLIANCE encourages each underlying OTIC to resolve internally the complaints and disagreements raised by its partners, clients or observers. O-RAN ALLIANCE has no intent and will not involve in the daily operations of OTIC and resulting normal business operation issues, which could be arbitrated or resolved by legal challenges among the involved parties. + +However, when O-RAN ALLIANCE receives the official request with convincing evidence that this guideline has been violated or the following situations have happened, O-RAN ALLIANCE will launch the formal investigation and may request the further information from all underlying parties + +- The behaviour of OTIC has seriously undermined the healthy operation of global OTICs. +- The OTIC is not following the testing process. For example, OTIC releases detailed test results without the written consent of participant (vendor). +- OTIC unable to fulfil its obligations and responsibilities with O-RAN ALLIANCE. + +The O-RAN Entity [3] can submit the complaint directly to O-RAN ALLIANCE, while the others can use the contact form at [www.o-ran.org](http://www.o-ran.org) for this purpose (as they have no access to O-RAN internal documents and procedures). + +The OTIC host(s) has/have the obligation to provide the information requested, as well as full rights to appeal and defend its/their position by providing evidence and supporting materials. + +O-RAN ALLIANCE will review the materials submitted by all parties, collect and verify all necessary information, and present the findings and preliminary recommendation to O-RAN ALLIANCE TSC/EC/Board, + +- 1 and follow the legal process defined in the Hosting agreement between the OTIC host and O-RAN ALLIANCE +- 2 for the disqualification process. +- 3 All participants in OTIC should be acquainted with the complaint rights and procedures (e.g. via OTIC charter, +- 4 testing agreements). + +# --- 1 Annex A (normative): OTIC application form + +2 The following application form is used during OTIC qualification process as described in Chapter 6. + +3 + +4 + +## Open Testing and Integration Centre – Application form + +### A. GENERAL INFORMATION + +| | | +|------------------------------------------------------------------|---------------------------------------------------------------| +| A1 Full name of OTIC | A1-1 Proposed O-RAN ALLIANCE designator of OTIC (3-4 letters) | +| A2 Link to OTIC web site | A3 E-mail address | +| A4 Correspondence address: street – city – country – postal code | | +| A5 Description and introduction of OTIC (max 100 words) | | +| Contact 1 | | +| A7 First name | A8 Surname | +| A9 Telephone number (incl. country code) | A10 E-mail address | +| A11 Responsibilities/duties | | +| Contact 2 | | +| A12 First name | A13 Surname | +| A14 Telephone number (incl. country code) | A15 E-mail address | +| A16 Responsibilities/duties | | + +*Note A1: Name of OTIC is unique and English name including word “OTIC”. The proposed OTIC name can be revised and harmonized during the review meeting.* + +*Note A1-1: Proposed O-RAN ALLIANCE designator of OTIC needs to be a unique identifier within O-RAN ALLIANCE and is subject to harmonization.* + +*The assigned O-RAN ALLIANCE designator will be mentioned in item F4.* + +#### 1 The designed single point of contact for all communication between OTIC and O-RAN ALLIANCE + +| | | +|-------------------------------------------|--------------------| +| A17 First name | A18 Surname | +| A19 Telephone number (incl. country code) | A20 E-mail address | + +#### 2 OTIC Applicant + +| | | +|--------------------------------------------------------------------------------------------------------------|--------------------| +| A21 Full legal name of company | | +| A22 Correspondence address: street – city – country – postal code | | +| The point of contact for all communication between applicant and O-RAN ALLIANCE during qualification process | | +| A23 First name | A24 Surname | +| A25 Telephone number (incl. country code) | A26 E-mail address | + +3 + +#### 4 B. HOSTS AND PARTNERS + +5 The OTIC has at least one host, and no or more partners. + +| | | +|--------------------------|-----------------------------| +| B1 Total number of hosts | B2 Total number of partners | +|--------------------------|-----------------------------| + +6 + +#### 7 Host 1# + +| | | +|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------| +| B3 Full legal name of company | | +| B4 Correspondence address: street – city – country – postal code | | +| Contact | | +| B5 First name | B6 Surname | +| B7 Telephone number (incl. country code) | B8 E-mail address | +| B9 O-RAN membership
Member (i.e. mobile network operator) Contributor Academic Contributor | | + +8 Note #: The OTIC has at least one host. The other host(s) is optional. Please copy the table if OTIC has more than one host. + +#### 1 Partner 1# + +| | | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------| +| B10 Full legal name of company | | +| B11 Correspondence address: street – city – country – postal code | | +| Contact | | +| B12 First name | B13 Surname | +| B14 Telephone number (incl. country code) | B15 E-mail address | +| B16 O-RAN membership
Member (i.e. mobile network operator) Contributor Academic Contributor
No O-RAN membership | | + +2 Note #: The OTIC has no or more partners. Please leave the table empty if OTIC has no partner, and copy the table if OTIC has more than one +3 partner. + +4 + +#### 5 C. PHYSICAL LAYOUT AND ARCHITECTURE OF LAB(S) + +6 The OTIC has at least one physical lab. An additional information about the lab(s) can be asked during +7 O-RAN ALLIANCE review meeting. + +| | +|--------------------------------------------------------------------------------------------| +| C1 Total number of physical labs | +| C2 Description of OTIC architecture (max 100 words) - the pictures/photos can be including | + +8 + +#### 9 Lab 1# + +| | +|------------------------------------------------------------------| +| C3 Name of lab | +| C4 Correspondence address: street – city – country – postal code | + +C5 Please describe the applied security and IPR protection mechanisms in the lab such as isolation of the lab from host own facilities (offices), capability of quickly setting up a separate work area with restricted access based on projects, etc. + +Note #: If OTIC has more than one lab, please copy the table. + +### D. SUPPORTED WORK SCOPE AND SERVICES + +Please tick the relevant box(es) based on the **current OTIC testing capabilities** (e.g. based on the available test and measurement equipment in the OTIC today). + +D1 Brief description of testing and other services currently supported by OTIC that can be offered to clients (text max 100 words) + +D2 Is anechoic chamber available in the OTIC? + +Yes, FR1 Yes, FR2 No + +D3 Is RF shielded chamber/room available in the OTIC? + +Yes, FR1 Yes, FR2 No + +D4 O-RAN Certificates and Badges that can be awarded by OTIC, as defined in Clause 5.3 [1] + +| Type of award | Interface under test | Device under test | RAT under test | +|---------------|----------------------|-------------------|----------------| +| | | | | +| | | | | + +### E. SELF-DECLARATION + +OTIC applicant declares fulfilment of the requirements for qualification as an OTIC HOST as defined in the Criteria and Guidelines of Open Testing and Integration Centre, dated ....., Version ..... OTIC applicant also hereby confirms the accuracy of data provided in this application form. + +Representative of OTIC applicant + +Date + +Signature + +1 + +### 2 **F. PROCESSING INFORMATION** + +3 Please do not fill the following items. The following items will be filled by O-RAN ALLIANCE. + +| | | +|---------------------------------------------------------------------------------------|-------------------------------------------------------------| +| F1 Date of application received | F2 Assigned reviewer | +| F3 O-RAN ALLIANCE unique reference ID for this application | F4 O-RAN ALLIANCE designator assigned to OTIC (3-4 letters) | +| F5 Recommendations and summary from the review meeting, and OTIC applicant statements | | + +4 + +5 + +- +- # Annex B (informative): Guidelines on OTIC application form +- VOID + +# --- 1 Annex C (normative): Hosting agreement + +- 2 After passing O-RAN ALLIANCE approval process, OTIC applicant will be required to sign the legally binding +3 Hosting agreement with O-RAN ALLIANCE. +4 + +### HOSTING AGREEMENT + +Between + + + +(“OTIC Host”) + +
+ +
+ +And + +**O-RAN ALLIANCE e.V.** + +(“O-RAN ALLIANCE”) + +Buschkauler Weg 27 + +53347 Alfter/Germany + +1. O-RAN ALLIANCE has accepted as OTIC HOST on . +2. O-RAN ALLIANCE confirms that OTIC HOST fulfills the requirements for qualification as an OTIC HOST as defined in the Criteria and Guidelines of Open Testing and Integration Centre, dated ....., Version ..... (“Criteria and Guidelines”) and as declared by OTIC Host in its self-declaration (OTIC application form). +3. OTIC HOST as the founder, main contact and main sponsor of OTIC will take full responsibility for all OTIC activities, including the organization as well as all budget and financial flows inside the OTIC. +4. OTIC HOST will in particular: + - a. Provide the space (test rooms, server rooms) for conducting of tests and hosting events (incl. IOT and conformance testing, PlugFest, PoC, demo), network connectivity, and test/measurement equipment, tools and services; these services may also be provided by partner(s) contracted by the OTIC HOST; + - b. Guarantee the openness and fairness to any client who has interest in testing its equipment in OTIC; + - c. Guarantee the credibility, confidentiality, openness and vendor-independence of OTIC; + - d. Guarantee that the agreed O-RAN ALLIANCE test procedures (e.g. for certification and badging) are properly followed, and the results are produced in agreed format and with certain level of quality and confidentiality; + +- e. Enter into agreements (e.g. participant agreement, testing agreement) with all other participants in OTIC; all agreements shall be in compliance with the criteria and requirements stated in the “Criteria and Guidelines”; + - f. Take all necessary steps (e.g. participation agreement, testing agreement, isolated space) to work towards protecting the intellectual property of each participant in OTIC; to safeguard intellectual property in all situations, e.g., outdoor equipment; + - g. Take all necessary steps to ensure that the used test and measurement equipment and tools are properly calibrated and ready to use; + - h. Allow the detailed results, blueprints, interface profiles, experiences, best practices, knowledges, lesson-learned, adopted processes, etc. to be shared following the confidentiality levels from the agreements; + - i. Regularly present the summary of testing results, experiences, best practices, knowledges, lesson-learned and adopted processes at O-RAN ALLIANCE TIFG meetings (and optionally on request to any other O-RAN ALLIANCE meeting); + - j. Host or multi-host designated representative responds to the request for information or testing results from O-RAN ALLIANCE in a timely manner; + - k. Acts as a mediator trying to resolve any complaint and disagreements inside OTIC raised by its partners, clients or observers; and + - l. Set-up a complaint resolution processes (incl. documentation of resolution of complaint) as described in the “Criteria and Guidelines”. +5. OTIC HOST has flexibility and authorization to negotiate and sign bilateral legal agreements with its partners, clients and observers. At minimum these agreements should include confidentiality, openness and fairness, and rights to share the testing/validation results according to the “Criteria and Guidelines”. +6. OTIC HOST must notify the O-RAN ALLIANCE immediately if any of the requirements for qualification as an OTIC Host as defined in the “Criteria and Guidelines” are not fulfilled any longer. +7. O-RAN ALLIANCE must notify OTIC HOST immediately if any of the requirements for qualification as OTIC HOST as defined in the “Criteria and Guidelines”, are changed. +8. There is no obligation to pay fees to O-RAN ALLIANCE. In case that OTIC HOST collects fees from OTIC participants O-RAN ALLIANCE reserves the right to charge fees for the use of its logos (e.g. “O-RAN”, “OTIC” ) and/or fees for O-RAN ALLIANCE qualification services. +9. Having regard to the considerable commercial value of confidential information, OTIC HOST shall keep confidential and secret and not disclose to any third party confidential information. "Confidential Information" means all financial, commercial, technical, operational, staff, management and other information, data and know-how relating to Specifications or Contributions, which may be supplied to or may otherwise come into the possession of the OTIC HOST, whether orally or in writing or in any other form, and which is confidential or proprietary in nature or otherwise expressed by the disclosing party to be confidential. +10. The restrictions on use and disclosure of Confidential Information as described above shall not apply to any information which: +- a) is already in the possession of the receiving party prior to its disclosure; + - b) is or comes into the public domain or otherwise ceases to be of a confidential nature other than as a result of wrongful disclosure hereunder by the receiving party; + +- c) becomes available to the receiving party on a non-confidential basis from a source other than the Disclosing Party or any of its Associates; +- d) is separately generated by the receiving party who are not privy to the Confidential Information; or +- e) is required to be disclosed by any law or order of a court of competent jurisdiction, recognised stock exchange, governmental department or agency provided that the receiving party (where legally permitted to do so) promptly notifies the OTIC HOST of any such requirement. +11. O-RAN ALLIANCE grants OTIC HOST a royalty-free, non-exclusive, non-transferable, non-sublicensable license to use the registered O-RAN logos (“O-RAN”, “OTIC”) solely for the purpose of this Hosting Agreement. In the event of termination of this Hosting Agreement, OTIC HOST must immediately cease all use of the Logo. +12. OTIC HOST will comply with the rules on data protection as provided by the European General Data Protection Regulation (GDPR) in effect since May 25, 2018. +13. O-RAN ALLIANCE reserves the right to suspend or withdraw OTIC HOST its status as OTIC HOST if it reasonably believes that OTIC is not in compliance with the terms of this Hosting Agreement by following the procedure described in the “Criteria and Guidelines”. The OTIC HOST shall reasonably cooperate with O-RAN ALLIANCE and provide all the requested necessary information and data during investigation of received complaints. +14. O-RAN ALLIANCE and OTIC HOST can terminate this Hosting Agreement without cause at any time with prior written notice of ninety (90) days. +15. Upon termination of this Hosting Agreement OTIC HOST shall on demand promptly return to or destroy all originals of Confidential Information, whether in paper or in electronic form, supplied to it and promptly destroy all copies made of the Confidential Information and all notes, memoranda and other documents or computer files or records prepared by it to the extent of the Confidential Information contained in them, provided that the Receiving Party may keep one copy of Confidential Information for archiving purposes. +16. OTIC HOST agrees and acknowledges that the obligations contained in this Hosting Agreement are legally binding upon it and that they will be construed and interpreted in accordance with German law. +17. The OTIC HOST agrees that any disputes which may rise out of or in connection with this Hosting Agreement or otherwise in connection with its involvement in or with the O-RAN ALLIANCE shall be finally settled under the Rules of Conciliation and Arbitration of the International Chamber of Commerce by one or more arbitrators appointed in accordance with these Rules. The OTIC HOST further agrees that the place of arbitration shall be Geneva/Switzerland and all proceedings in the arbitration shall be in English. +18. The obligations in this Hosting Agreement in respect of confidentiality shall survive termination of this Hosting Agreement howsoever arising. + +Signatures: + +Company Name (“OTIC Host”): ..... (Name and Date) + +O-RAN ALLIANCE e.V.: ..... (Name and Date) + +## Annex: Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2020.07.02 | 01.00 | First published version | +| 2020.11.07 | 02.00 | The details of OTIC qualification process have been added in Chapter 4. The OTIC application form has been added in Annex A. | +| 2021.05.07 | 03.00 | The format of document has been changed from technical specification to process document. The OTIC application approval process has been updated in Chapter 4. The Hosting agreement has been added in Annex C. The OTIC application form in Annex A has been extended by Self-declaration. | +| 2022.06.01 | 04.00 | Legal review of the document. The guidelines on mapping of OTIC testing capabilities and services to OTIC application form have been added to Annex B. The OTIC application form in Annex A has been updated. The format and structure of document has been updated according to the latest O-RAN templates. | +| 2023.03.01 | 05.00 | Harmonization of OTIC names – adding requirements on OTIC names and recommended naming convention (scheme) in chapter 6.1. The changes which require additional O-RAN approval have been listed in chapter 6.1. Limitation of 2 months on duration of OTIC review process has been added to chapter 6.2. The OTIC application form (Annex A) has been updated accordingly, and new item for O-RAN ALLIANCE designator has been added. | +| 2025.01.15 | 06.00 | Updated and simplified OTIC application form in Annex A. Alignment of terminology with O-RAN Working procedures and O-RAN Constitution. Clarification of who can be OTIC host, including O-RAN Contributors as well as O-RAN Academic Contributors. | \ No newline at end of file diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/03dcfa5ba917d3e7a6b90a625c7f4c22_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/03dcfa5ba917d3e7a6b90a625c7f4c22_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..65d16dc49a336b793e67db00cc87b729e4184409 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/03dcfa5ba917d3e7a6b90a625c7f4c22_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:31a657788ea40acd5b6635a3b9cbceb36ef878ccc75408641d21c8b0881a8666 +size 103480 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/03f828d91e77a946ce3f49835b6c5e6d_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/03f828d91e77a946ce3f49835b6c5e6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b295dda76a55984bdd88c5212fc3c1540a27ba58 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/03f828d91e77a946ce3f49835b6c5e6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bf38b41290d1bb6883ea534549059a2bdcccda246ed97984ae7f029e70609911 +size 73678 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/06cc03130b7521e6d612848328058971_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/06cc03130b7521e6d612848328058971_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..80b32ae6b15b0e02662ba30cf6682c3671b345d2 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/06cc03130b7521e6d612848328058971_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a3c37584521ce3a24544c5939d41ed4b90dec08b3aea502adf003a0455953f7a +size 42667 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/17398cfc35dde22fa5a80caabe669739_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/17398cfc35dde22fa5a80caabe669739_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ae115f85c71c7c4dd5ac246f8d02e9dc29c8af6 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/17398cfc35dde22fa5a80caabe669739_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c5775240b9ed1a2100a9c61aca08d03763ec191986acc2c52895232c0e85e48b +size 4429 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/1888ee625428705c060330e16bdc98e4_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/1888ee625428705c060330e16bdc98e4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1777b8b48f952e6695498aa6bd1b9dac95fa2268 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/1888ee625428705c060330e16bdc98e4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a936bb5e6f8b0b110efc7480c5c7b25520077625ee8bd60264dba780ba0f2e84 +size 70773 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/18ff94108cfd32923ac3f51474673bbd_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/18ff94108cfd32923ac3f51474673bbd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..48bb9153e5843a76f41539ec770f50bb6df33eab --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/18ff94108cfd32923ac3f51474673bbd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:afb572cc601c5d501b4e3ab690c80c5b2d7029d8d93f67986e67e55e9eca5a3b +size 20420 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/196fa23217272842f4fad36db8c56381_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/196fa23217272842f4fad36db8c56381_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..46010350fb9e8927aae948d0b02de96b633caeeb --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/196fa23217272842f4fad36db8c56381_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9628218a424887301395f504050e40eabda514b2bc347949835df31c396c0b06 +size 86377 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/259e0e49e862fefad5badd9e00e33bb0_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/259e0e49e862fefad5badd9e00e33bb0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7f743401f7196c88cd7bca9955f87462dca02462 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/259e0e49e862fefad5badd9e00e33bb0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:39d47cc110524a807523898030b75a8092f85f270f414879ab642c71b6cb88d4 +size 37058 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/28262e4c1f42c1f16c8d8da339e79bad_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/28262e4c1f42c1f16c8d8da339e79bad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a107023b74547ec17c78a5ffa80205287e495237 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/28262e4c1f42c1f16c8d8da339e79bad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:28c25b62f0f3d670dee31b08eb3b1128e4d967adc1d99e95601185aebdbbc9f5 +size 29806 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/2bb5e11ae9becc0673a1c2d4ee74b34d_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/2bb5e11ae9becc0673a1c2d4ee74b34d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..178e81c4b0404f96c2fcce2439f1aa196959bef8 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/2bb5e11ae9becc0673a1c2d4ee74b34d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:eb38d94b3d451f81f5977208e8d5fe1a6231fc06f2024959cc5376c0c047824e +size 31400 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/31bc8f4b672b01aecc0eaf4ca72692cf_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/31bc8f4b672b01aecc0eaf4ca72692cf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1c3e1a9e574624779a67cd5163ac4fdb984ca2c5 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/31bc8f4b672b01aecc0eaf4ca72692cf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0f1d4bd235b4ee54ff8678e5ea95e3a5aaacd3be9f7eeb75535b125205076c3b +size 53793 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/336d4382018733a9932bef307cc8d6db_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/336d4382018733a9932bef307cc8d6db_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..55f4b6707e1df91882ba4688661bd921e9394207 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/336d4382018733a9932bef307cc8d6db_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:13b10c1e2fcab79688ce70a0a2ed1fdca132adf0f47edd30293d2853c3008901 +size 30151 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/410b033b9d4c6f2e81e9bca9c4b36c58_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/410b033b9d4c6f2e81e9bca9c4b36c58_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9ed63f039a24f2f23359bf83b023687887c96cdf --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/410b033b9d4c6f2e81e9bca9c4b36c58_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:01287774ee05c62b0d02779cc7ad093d7f8c583c6eac350d8d1e59df0bb6f646 +size 50657 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/5404f6eae2b2e63d42620574e82bfb20_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/5404f6eae2b2e63d42620574e82bfb20_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6216d0ddb207da95e068b38d1da00764211b129e --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/5404f6eae2b2e63d42620574e82bfb20_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5b2fed159dc915cdb491c19c5279c420bf2c9cc76d2644d8f5b205e66612e858 +size 35458 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/551e35d264492786d0d610557ccc1b55_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/551e35d264492786d0d610557ccc1b55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eca96f14eff173ab5ead5b4ef80ff5827e92c33d --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/551e35d264492786d0d610557ccc1b55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8bb0af2dd788e055159db7a05c0b9285e7d655c861421ac8dc37e4b94c3b343 +size 4454 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/554e038618f507726cc8b241ae1cec25_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/554e038618f507726cc8b241ae1cec25_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7c6329555ac1048749739650412fb77a59ad2eff --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/554e038618f507726cc8b241ae1cec25_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d2909f525bab92c526a4c18a405457d19cefa3e6c49a3b010acf612db3cc673 +size 98931 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/565dd18bba42c55b8c5a3b3ae5be942f_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/565dd18bba42c55b8c5a3b3ae5be942f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3c8ca523dd1b00c837ce54b778926adb2ab976a6 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/565dd18bba42c55b8c5a3b3ae5be942f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bd1e05d0dc01ebcacad4cb74b67f16fbafc0bfc133962f9b80f391b0e0df70ec +size 62015 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/5aace8e5ed93e3e25877049b1f39e821_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/5aace8e5ed93e3e25877049b1f39e821_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0470a28f78908d625e6dfd2f2434695b8341d8db --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/5aace8e5ed93e3e25877049b1f39e821_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ba7699ad2a7a03c14b4f8dfd7700f8f00bc8575b90cb12218538b1d9740c8596 +size 94143 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/60267c4dbb6f9023b9ec29911cea785c_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/60267c4dbb6f9023b9ec29911cea785c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ff461de39d3b021ee47dc42677731acb27aa8aa1 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/60267c4dbb6f9023b9ec29911cea785c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:25323799aa985f790f0c6bfc905bc250a03354a254df6f537bfb6606481ae468 +size 52073 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/6920165771ff0f4446c12c22e3a3dd73_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/6920165771ff0f4446c12c22e3a3dd73_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ad95b65aa56e3a3c7251cb09ef176e347266b98f --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/6920165771ff0f4446c12c22e3a3dd73_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:608037e0fcf8e701834870799dee2e284a7de4dc3e31d21764998997fa808e3b +size 62231 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/6af530a1c7409881ba24e524bea43416_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/6af530a1c7409881ba24e524bea43416_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1f6fcb97b53be534b09b03f58de954b26bd8ec05 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/6af530a1c7409881ba24e524bea43416_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6029851e2b34cdd939dda3a4a78a9e5cf7db025f23f84333829825a91dfb9fc6 +size 52156 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/70067f1c59305d0a4616a1c44345c3a1_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/70067f1c59305d0a4616a1c44345c3a1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d30c8f54ee185dbfc1bc5c5d6a9e920209546f7c --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/70067f1c59305d0a4616a1c44345c3a1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7fb0928a66e5ee96845c0522fc088037f69b879fc150c03de4359ec2b36d756 +size 20009 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..27225d0aa300adaafdd4117dedc67749d0a1a206 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48cf233b970eeaabdd503be04bfc1c953c2305a08074046287524dfb5e1dcd7c +size 4522 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/7c53b30bc956683048b1ba4ee2844709_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/7c53b30bc956683048b1ba4ee2844709_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..311812599680f06493004ed6431b703f5be8b755 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/7c53b30bc956683048b1ba4ee2844709_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a085e189780b5c4d92d7f8ed3c5766b6a1f7bc94d1286322caff7e02a92fa95a +size 68579 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/803c8101f8d02d7c41769b64b2d0e62a_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/803c8101f8d02d7c41769b64b2d0e62a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f946a3644cbd6954d1b2b0681e2553444126c613 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/803c8101f8d02d7c41769b64b2d0e62a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1444dd574582c4a625c6dd91cee4026916748ea9823e477623d8aa4dd83b065f +size 23393 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/8581f33c1999a1354e8873775b162d59_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/8581f33c1999a1354e8873775b162d59_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..071ae1b7325d8c82f21a56280d45391121922834 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/8581f33c1999a1354e8873775b162d59_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3cf820a54cf3cb8b6045f420e9cecde0f7e1ce3e1eecb6d55a381d7d0c1f64c5 +size 111646 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/87718488ca18f47cd5e14bf3fd1fae10_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/87718488ca18f47cd5e14bf3fd1fae10_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9d211f8015def2336e3b62eadc37f38275372a9c --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/87718488ca18f47cd5e14bf3fd1fae10_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c89f9aa85cfb22654a4130685fb452221ca5d94d5de033b2c2de7065c77e1bda +size 68088 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/8c30ab0353ab3cb6e664dae43b3ffb90_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/8c30ab0353ab3cb6e664dae43b3ffb90_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b3cf9ff63ba05d6511ce245effe2cddfe36d8ccb --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/8c30ab0353ab3cb6e664dae43b3ffb90_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:08516677d82a9cefe9ba21dc04690acaa01a94aa52ba16578d993b34faff799d +size 25575 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/9028c32165bb5a73aa33e052a3403bc0_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/9028c32165bb5a73aa33e052a3403bc0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..af8f1db6be738468e5f40e95df5156359fc3efe6 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/9028c32165bb5a73aa33e052a3403bc0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:acf3d70cc3c8d54eeb09c98bb4d9449bb65aada2e8cafa537f70ce5f11f80577 +size 58091 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/95874aa51378beec8a9cbfce6506d59c_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/95874aa51378beec8a9cbfce6506d59c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ef6de1e76ab490b47aa139cbc22dcddfd784c1e0 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/95874aa51378beec8a9cbfce6506d59c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8dc340397160f080acaca11ca29e269d877a752719ae779c8f6a31d954c91c2b +size 24324 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/96ae7c777b0f6fccab0765df519f6626_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/96ae7c777b0f6fccab0765df519f6626_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c6e3149a423ddd94d7cdf96133e9c7ba7279ef32 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/96ae7c777b0f6fccab0765df519f6626_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f4b00c94630d9a5cd9df899829455adc1bdca26b384d9d33bab199f634f29e11 +size 4618 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/99c3e335244363bb828cfbe6b0be81e4_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/99c3e335244363bb828cfbe6b0be81e4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eb8f2e55ac0cc993ec96ad3f999a2768f648bc14 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/99c3e335244363bb828cfbe6b0be81e4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:86817ad49e77f20a3a976b29d70cef80a03f2dda2c5659a964c139d781afc252 +size 27190 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/9c212a58170560c3e66df203432612b5_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/9c212a58170560c3e66df203432612b5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d8567ce28227a45c81429a643877d0b4809e9362 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/9c212a58170560c3e66df203432612b5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:266862fc6c664ec023e379787871fcaff0418a34204c29f53e9e110ddf9483d7 +size 111548 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a0129d2fd175a79700e27a15ed7707d3_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a0129d2fd175a79700e27a15ed7707d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d061827d3d50da15063295e9f50a8fe8fc03acbe --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a0129d2fd175a79700e27a15ed7707d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a035b29f82b0be1a91029772423f6aa23cdec20b10c95a6bbdb5c634723327e +size 121192 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a0e3dd059b2b008183fc3324fbba6313_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a0e3dd059b2b008183fc3324fbba6313_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dd237bad62d5c36e7c804ac7e2b54654dd95b4ca --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a0e3dd059b2b008183fc3324fbba6313_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:56487f213230c010320110d04a47b5381c0102c63fc30f3f54a31f1ca0875253 +size 40207 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a86181562e07b63d9ceb5af4373a63cb_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a86181562e07b63d9ceb5af4373a63cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ec37170c471c7ee08150fdf4ec626e9fcd996173 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/a86181562e07b63d9ceb5af4373a63cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8f304d3b48f947e0d7e0878b0b7329a566390fdbf7676e7857d1d2f726646977 +size 27339 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/ba65434ddc0b64ba1ac9b29466731449_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/ba65434ddc0b64ba1ac9b29466731449_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fb168be4853dafd87fb9ae477ec47a343a29d163 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/ba65434ddc0b64ba1ac9b29466731449_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a3cb1a3e89711c33b1c8a4f82f1119d34a16f45b806b03e6fc1d26d175e36138 +size 43557 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/bd4e5e15cc89e678a9da145b30032e05_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/bd4e5e15cc89e678a9da145b30032e05_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9ca36af4019624fab0e484e9b754ee6370259350 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/bd4e5e15cc89e678a9da145b30032e05_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3c792894dc6c549eceb1a3c1c3b113a5e7e639623f49cb9144b7587d023ebeba +size 70346 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7575c364a05dd515d7cf096c30ffc26f8ab2631 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b321cfff0a169d11fa6daa2e14ee4667e12bcfeff34e35ee9dd80b810a6385a6 +size 4491 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c1ad6966d7bf54e2d84b918ae152c182_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c1ad6966d7bf54e2d84b918ae152c182_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2b6dad9eb93fd6e95c696783ce08864fbccffd6c --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c1ad6966d7bf54e2d84b918ae152c182_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ac178dc3ddd93abf0ba3df33b6a32f2d47d4b9010dd1fcb7740fbebd8e485783 +size 78637 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2b90693e69025867d0dd05d8f98d4ef9b4bf8d2 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ed2f1f4ac06a8bc6ac44f6e3f61e762e6c8489952cf16d65bfea30fe61adb2af +size 4677 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c5ef9409d26ded005d68c9026b489852_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c5ef9409d26ded005d68c9026b489852_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..94b20230ab47a36031bbf10474c8060929f9f90f --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c5ef9409d26ded005d68c9026b489852_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4d7f447704fbabfb2c9f6ba85363e86c7b88c9229bd37823b13cbda3779c7ec4 +size 50656 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c8214cd9d6a6cca9090cc644f55ce18e_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c8214cd9d6a6cca9090cc644f55ce18e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..224ffa3fdc58770aed0adf664c6e5e0e099e7302 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c8214cd9d6a6cca9090cc644f55ce18e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f3efe4072e753cac1df2684b392e21a94775f25490595a2ae63538b0c50e567b +size 106361 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c9579d02c740bb5b962a9a6c2f294b81_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c9579d02c740bb5b962a9a6c2f294b81_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cf019c5c517880d3c6deb4ace5cf45c3fc095a49 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/c9579d02c740bb5b962a9a6c2f294b81_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:39418f9f0c9e1c9a12d24854b55cebf2b0211f1c25811a2db1645033325a8aab +size 30355 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/ce04fbaa71472de905f15821fc612928_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/ce04fbaa71472de905f15821fc612928_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6eed1f81290e9bcaf2b8dec77ec25614024c08c5 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/ce04fbaa71472de905f15821fc612928_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c2d38e4716a3c07b39c92d9b41a8197cbabe0351f5f0d5fc30804a3975a627bb +size 66923 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/d6027f3fec5389568b6bf8b485af78d3_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/d6027f3fec5389568b6bf8b485af78d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9df95e51de332bdddb12edf0202dc02a9b127c03 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/d6027f3fec5389568b6bf8b485af78d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:12333bbbdb9992d70578b62257384350c83115f54b0516ba951b980b5de48364 +size 19042 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/dd678240756573d5ab9e828fc6342326_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/dd678240756573d5ab9e828fc6342326_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9d78a0f8017575c55bc25f743a542f3e16b07549 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/dd678240756573d5ab9e828fc6342326_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:585dcf46470e2aa837735115f7dc99ddc591c306a68de5efd543699eb23a2d88 +size 92093 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/de74b39b3a82582e4c88109e05a3ff4b_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/de74b39b3a82582e4c88109e05a3ff4b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..34c74f71fa55084cff25f0e7a476e172aec8a142 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/de74b39b3a82582e4c88109e05a3ff4b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:431698b1033cb20db66d955d908d5cf6a1b2ced6717749accaf8cfda0916227e +size 64280 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e3ec9fecd9eb830cea91602ce61df3c0_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e3ec9fecd9eb830cea91602ce61df3c0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0c90c10e1f1ea06eb61b8712c2dd8b9264c81573 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e3ec9fecd9eb830cea91602ce61df3c0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:67f081a3a65b24475e4ebdae226d0a95674de610671ed22c7f13cdadd7e26599 +size 26500 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e4d50af8413156c0de6a43a9d05385f9_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e4d50af8413156c0de6a43a9d05385f9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9c62c1554fa9000a43ed8534eb8a001a8fce9f32 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e4d50af8413156c0de6a43a9d05385f9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ff79298f4f597363303b89f1abe5ec7954afd8477343fdba0006d9ee81f9d411 +size 4604 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e73ed7c944b9c3dc5e974a1d518a7a7d_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e73ed7c944b9c3dc5e974a1d518a7a7d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c29c8d78f92f31cc760ca12cd328dccbe2263f34 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e73ed7c944b9c3dc5e974a1d518a7a7d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cbc620e6e009ee60f47de9690b78ebc674702d0284bca80f7532ebcae6e2080a +size 9052 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e8aa6bf8bc13ebc796dc47cd4ac643d8_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e8aa6bf8bc13ebc796dc47cd4ac643d8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eb31725eab942de7f5a68c0adc66850cb4b5f788 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/e8aa6bf8bc13ebc796dc47cd4ac643d8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4578996ff76503fc6f1073aa4e4f24ab390ccf95af2fd915d73d20ea8d75a7a5 +size 77692 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/ed531c361515dbdc198449009c8b2d7c_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/ed531c361515dbdc198449009c8b2d7c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0835a6fe8b3d1724f873e0c4364b471d9536be8a --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/ed531c361515dbdc198449009c8b2d7c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2749273a1e979a9b63357c46170ade32e2c88b206bd7f0fc8c08fbc7f67891ae +size 4561 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f1ab6dab782d6f357c8a476c8e1c6c44_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f1ab6dab782d6f357c8a476c8e1c6c44_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d1ce5ba31b8d97d8f591afc8fcc1b281784bcbc --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f1ab6dab782d6f357c8a476c8e1c6c44_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5ec7c7620a39d2c45f011c135be51fc06baa2a0b4ccc9b9d9903671a44aaaea4 +size 23118 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f53ab3e2fe50b38ed8629ca5467d89b0_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f53ab3e2fe50b38ed8629ca5467d89b0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ffc58e901d306519ceed155a59ce5639bcdc6db3 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f53ab3e2fe50b38ed8629ca5467d89b0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b55ffa8ba963d87052c9ac16d9c9831f3b86b67aaa956cddedc4ab4ba0094a74 +size 86527 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f86354091231e648768ce7c0ab343658_img.jpg b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f86354091231e648768ce7c0ab343658_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..41fdf5475ebd58aecd68d9bbc7e45dae6896edd8 --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/f86354091231e648768ce7c0ab343658_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c5e7326add008d72dcaa561b072067005cca22758f5bcbba06d94d99ee8336ac +size 49155 diff --git a/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/raw.md b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..b4d8b4cf8b0544c15bdcf9950782219e3e2ef53b --- /dev/null +++ b/marked/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00/raw.md @@ -0,0 +1,2120 @@ + + +# **O-RAN Test and Integration Focus Group****End-to-End System Testing Framework Specification** --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Test and Integration Focus Group****End-to-End System Testing Framework Specification** --- + +Prepared by the O-RAN Alliance. Copyright © 2020 by the O-RAN Alliance. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in Annex *ZZZ* of this specification. All other rights reserved. + +1 + +# --- Revision History + +2 + +| Date | Revision | Description | +|------------|----------|-------------------------| +| 07/07/2020 | 01.00 | First published version | + +3 + +# Contents + +| | | | +|----|--------------------------------------------------------------------------------------------------------|----| +| 1 | Revision History ..... | 2 | +| 3 | Chapter 1 Scope and Definitions ..... | 5 | +| 4 | 1.1 Scope ..... | 5 | +| 5 | 1.2 References ..... | 5 | +| 6 | 1.3 Definitions and Abbreviations ..... | 5 | +| 7 | 1.3.1 Definitions ..... | 5 | +| 8 | 1.3.2 Abbreviations ..... | 6 | +| 9 | 1.4 Revision Guideline ..... | 6 | +| 10 | Chapter 2 Introduction ..... | 7 | +| 11 | Chapter 3 O-RAN Architecture and Deployment Scenarios ..... | 9 | +| 12 | 3.1 O-RAN Logical Architecture ..... | 9 | +| 13 | 3.2 O-RAN Cloud Deployment Scenarios ..... | 12 | +| 14 | Chapter 4 O-RAN Deployment Blueprints ..... | 15 | +| 15 | 4.1 Introduction ..... | 15 | +| 16 | 4.2 System Profiles ..... | 15 | +| 17 | 4.3 Subsystem Instance Profiles ..... | 17 | +| 18 | 4.3.1 Relationship between Subsystem Type and O-RAN network functions ..... | 18 | +| 19 | 4.4 Subsystem Pair Interoperability Profiles ..... | 19 | +| 20 | Chapter 5 O-RAN End-to-End (E2E) Testing Framework ..... | 22 | +| 21 | 5.1 Stages and Sequence of Testing ..... | 22 | +| 22 | 5.2 Subsystem Testing ..... | 25 | +| 23 | 5.3 Subsystem Pairing and Open Interfaces Interoperability Testing ..... | 31 | +| 24 | 5.4 E2E System Multi-vendors Interoperability Testing ..... | 34 | +| 25 | 5.4.1 Subsystem Replacement Testing ..... | 35 | +| 26 | Chapter 6 O-RAN E2E Test Cases and KPIs ..... | 37 | +| 27 | 6.1 Introduction ..... | 37 | +| 28 | 6.2 Use Cases and Services Requirements ..... | 37 | +| 29 | 6.3 O-RAN Deployment Blueprint dependencies ..... | 38 | +| 30 | 6.4 Relevance of the 3GPP KPIs ..... | 38 | +| 31 | 6.4.1 3GPP KPIs defined for network monitoring, assessment, analysis, optimization and assurance ..... | 38 | +| 32 | 6.4.2 Applicability to RAN, RAN Slices, Users and Services ..... | 39 | +| 33 | 6.5 Relevance of the NGMN 5G Test Cases and KPIs ..... | 39 | +| 34 | 6.6 Test Conditions to be considered ..... | 40 | +| 35 | 6.6.1 Multi-vendors interoperability ..... | 40 | +| 36 | 6.6.2 Functional, Performance including normal and abnormal conditions ..... | 41 | +| 37 | 6.6.3 Radio channel variations and impacts on the overall system performance and QoE ..... | 41 | +| 38 | 6.6.4 Management, Orchestration and Network Automation ..... | 41 | +| 39 | 6.6.5 Additional considerations related to practical deployment aspects ..... | 42 | +| 40 | 6.7 Test Scenarios and KPIs to be considered ..... | 42 | +| 41 | 6.7.1 Mobility Management ..... | 42 | +| 42 | 6.7.2 Deployability ..... | 43 | +| 43 | Annex A: Operators' inputs on Deployment Blueprints ..... | 44 | +| 44 | A.1 Operator #1 inputs ..... | 44 | +| 45 | A.2 Operator #2 inputs ..... | 49 | +| 46 | A.3 Operator #3 inputs ..... | 50 | +| 47 | A.4 Operator #4 inputs ..... | 51 | +| 48 | Annex B: O-RAN Software Community inputs on Testing Methodology ..... | 54 | +| 49 | B.1 O-RAN Software Community ..... | 54 | +| 50 | B.2 OSC Development Cycles ..... | 54 | +| 51 | B.3 OSC Software and Test Deployment Architecture ..... | 55 | +| 52 | B.4 OSC Release Objectives ..... | 56 | +| 53 | B.5 OSC Testing ..... | 56 | + +| | | | | +|----|-----|----------------------------------------------------------------------------------------|----| +| 1 | B.6 | References ..... | 57 | +| 2 | | Annex C: Test Functions, Tools and Solutions for Subsystem and E2E System Testing..... | 58 | +| 3 | | Annex D: References to O-RAN WG6 Cloud Deployment Scenarios ..... | 63 | +| 4 | | Annex ZZZ: O-RAN Adopter License Agreement ..... | 66 | +| 5 | | Section 1: DEFINITIONS ..... | 66 | +| 6 | | Section 2: COPYRIGHT LICENSE..... | 66 | +| 7 | | Section 3: FRAND LICENSE..... | 66 | +| 8 | | Section 4: TERM AND TERMINATION ..... | 67 | +| 9 | | Section 5: CONFIDENTIALITY ..... | 67 | +| 10 | | Section 6: INDEMNIFICATION ..... | 67 | +| 11 | | Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 67 | +| 12 | | Section 8: ASSIGNMENT ..... | 68 | +| 13 | | Section 9: THIRD-PARTY BENEFICIARY RIGHTS ..... | 68 | +| 14 | | Section 10: BINDING ON AFFILIATES ..... | 68 | +| 15 | | Section 11: GENERAL ..... | 68 | +| 16 | | | | +| 17 | | | | +| 18 | | | | + +# Chapter 1 Scope and Definitions + +## 1.1 Scope + +This document is used to define the End-to-End System (E2E) Testing Framework for O-RAN Alliance. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. + - For a specific reference, subsequent revisions do not apply. + - For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document. +- [1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications” +- [2] O-RAN Operations and Maintenance Architecture, v03.00, April 2020, O-RAN Alliance +- [3] O-RAN Architecture Description, v02.00, August 2020, O-RAN Alliance +- [4] O-RAN Cloud Architecture and Deployment, v02.01, August 2020, O-RAN Alliance +- [5] O-RAN Cloud Platform Reference Design for Deployment Scenario B, v01.00, April 2020, O-RAN Alliance +- [6] O-RAN Fronthaul Control, User and Synchronization Plane Specification, v04.00, August 2020, O-RAN Alliance +- [7] O-RAN Fronthaul Management Plane Specification, v04.00, August 2020, O-RAN Alliance +- [8] O-RAN Use Cases and Deployment Scenarios White Paper, February 2020, O-RAN Alliance +- [9] 3GPP TS 28.554: “Management and orchestration; 5G end to end Key Performance Indicators (KPI)” +- [10] Definition of the Testing Framework for the NGMN 5G Pre-Commercial Network Trials, Version 3, July 2019, NGMN +- [11] O-RAN Indoor Picocell Hardware Architecture and Requirement (FR1 Only) Specification, v01.00, April 2019, O-RAN Alliance +- [12] O-RAN Deployment Scenarios and Base Station Classes for White Box Hardware, v01.00, December 2019, O-RAN Alliance + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in this section and the following listed references apply. A term defined in the present document takes precedence over the definition of the same term, if any, in the following listed references. + +1. 3GPP TR 21.905 [1] +2. O-RAN Operations and Maintenance Architecture [2] + +**O-RAN Deployment Blueprint:** defined as the set of inputs which is used to describe a specific O-RAN deployment from several aspects. These aspects include the specification of the O-RAN deployment at the System level (e.g. architecture, performance metrics) as well as Subsystem level and the Interfaces between the specified Subsystems. This would then allow definition and documentation of the testing methodology and the test cases using the blueprint specification. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [1]. + +| | | +|-------------|--------------------------------------------------| +| CNF | Cloud-Native Network Function | +| DUT | Device Under Test | +| E2E | End to End | +| FHGW | Fronthaul Gateway | +| FHM | Fronthaul Multiplexer | +| IUT | Interface Under Test | +| KPI | Key Performance Indicator | +| Near-RT RIC | Near-Real Time RAN Intelligent Controller | +| NMS | Network Management System | +| Non-RT RIC | Non-Real Time RAN Intelligent Controller | +| O-Cloud | O-RAN Cloud Platform | +| O-CU | O-RAN Central Unit | +| O-CU-CP | O-RAN Central Unit – Control Plane | +| O-CU-UP | O-RAN Central Unit – User Plane | +| O-DU | O-RAN Distributed Unit | +| O-eNB | O-RAN eNB | +| O-RAN | Open RAN | +| O-RU | O-RAN Radio Unit | +| OSC | O-RAN Software Community | +| PNF | Physical Network Function | +| RSAC | Requirements and Software Architecture Committee | +| SLA | Service Level Agreement | +| SMO | Service Management and Orchestration | +| SUT | System Under Test | +| VNF | Virtual Network Function | + +## 1.4 Revision Guideline + +This Technical Specification has been produced by the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +# Chapter 2 Introduction + +This document defines the End to End (E2E) testing framework for comprehensive E2E testing and validation of the Open RAN (O-RAN) Systems ensuring robust interoperability and operate with high performance as intended in real-world deployments. + +Figure 2-1 shows the focus on the O-RAN System as the System under Test (SUT) in the context of the E2E testing framework specified in this document and in relation to the E2E KPIs defined between the UEs and Services which will be further elaborated in this specification. Refer to [3] and Section 3.1 in this specification for more details on the O-RAN System. + +![Figure 2-1: Focus on O-RAN as the System under Test (SUT). The diagram illustrates the E2E testing framework. A large blue double-headed arrow at the top is labeled 'End to End (E2E) KPIs'. Below it, a sequence of components is shown: 'UE' connected to 'O-RAN System' via a dashed line labeled 'Uu'. The 'O-RAN System' is connected to '3GPP Core' via a solid line labeled 'S1, NG'. The '3GPP Core' is connected to '3GPP Services' and 'Other Services'. A bracket under the 'O-RAN System' is labeled 'Focus of System under Test (SUT) in this specification'. A separate box on the right is labeled 'System under Test (SUT)'.](8c30ab0353ab3cb6e664dae43b3ffb90_img.jpg) + +Figure 2-1: Focus on O-RAN as the System under Test (SUT). The diagram illustrates the E2E testing framework. A large blue double-headed arrow at the top is labeled 'End to End (E2E) KPIs'. Below it, a sequence of components is shown: 'UE' connected to 'O-RAN System' via a dashed line labeled 'Uu'. The 'O-RAN System' is connected to '3GPP Core' via a solid line labeled 'S1, NG'. The '3GPP Core' is connected to '3GPP Services' and 'Other Services'. A bracket under the 'O-RAN System' is labeled 'Focus of System under Test (SUT) in this specification'. A separate box on the right is labeled 'System under Test (SUT)'. + +**Figure 2-1: Focus on O-RAN as the System under Test (SUT)** + +Mobile operators will likely plan for many different variants of O-RAN Systems depending on their strategies and use cases which they may be interested to test, deploy and evolve their O-RAN compliant networks over time. The E2E testing framework will therefore need to take into consideration the Operators' O-RAN deployment variants given its influence on the scope of E2E testing. + +The concept of O-RAN Deployment Blueprint is introduced in this specification and is used to describe the different deployment variants of O-RAN Systems for E2E system testability purposes. This document provides the definition of the O-RAN Deployment Blueprint template which contains the necessary descriptors to build O-RAN Deployment Blueprints. + +A set of typical O-RAN Deployment Blueprints are defined using the most common deployment scenarios abstracted from various surveys which O-RAN Alliance has gathered from global operators. O-RAN Test and Integration Focus Group (TIFG) focuses on the definition of the E2E testing framework based on addressing the needs of these most common and probable deployment scenarios. + +Operators and O-RAN Software Community (OSC) have submitted additional detailed inputs on their O-RAN Deployment Blueprints and testing practices respectively, to assist O-RAN Alliance with developing comprehensive E2E testing methodologies and test cases. These inputs are included in this specification for referencing purposes. + +**Chapter 3** starts with a brief introduction of the O-RAN logical architecture, O-RAN network functions and open interfaces between the O-RAN network functions. These O-RAN network functions and open interfaces are mapped to a list of the most considered use cases driven O-RAN cloud deployment scenarios. + +**Chapter 4** defines the O-RAN Deployment Blueprint, Template and its associated Profiles which are used to describe the O-RAN Deployment Blueprint. The O-RAN network functions and open interfaces are mapped to the various descriptors of the O-RAN Deployment Blueprint. Detailed definition of the various profiles' templates will be considered in the future releases of this specification. + +**Chapter 5** details the O-RAN E2E Testing Framework by providing guidance on the Testing Methodology for holistic testing and evaluation of the O-RAN Deployment Blueprints ensuring that these Blueprints can be robustly tested and optimized, ensuring consistent high quality and performance in a deterministic, repeatable and reproducible manner across the entire technology lifecycle. + +**Chapter 6** provides guidance on the key considerations along with information to help guide testing and validating the O-RAN Deployment Blueprints with the relevant E2E Test Cases and KPIs. Recommendations on the specific E2E Test Cases and KPIs will be considered in the future releases of this specification. + +**Annex A** lists the O-RAN Deployment Blueprints which have been submitted by global operators to O-RAN Alliance with the intention to assist with developing comprehensive E2E testing methodologies and test cases taking into considerations these submitted Blueprints. + +**Annex B** provides an overview on the O-RAN Software Community (OSC) work and its current software releases and testing practices. + +**Annex C** provides an example listing of the test functions and test tools and the applicability these test functions and tools for Subsystem and E2E System Testing. + +**Annex D** references common deployment scenarios abstracted from various surveys which O-RAN Alliance has gathered from global operators and defined by WG6 (Orchestration and Cloudification WG). + +The E2E testing framework specified in this document intend to fully leverage the Technical and Test specifications which the O-RAN Alliance Working Groups (WGs) have developed. + +# Chapter 3 O-RAN Architecture and Deployment Scenarios + +This chapter gives an overview of the O-RAN Logical Architecture, O-RAN network functions, open interfaces and a list of the most considered use cases driven O-RAN Deployment Scenarios which show how the O-RAN network functions are mapped to physical implementations in terms of how these network functions are realized as physical, virtual or cloud native network functions, aggregation/dis-aggregation of these network functions and where these network functions can be deployed in the network (e.g. Cell Site, Edge Cloud, Regional Cloud). + +The information provided in this Chapter facilitates definition of the O-RAN Deployment Blueprint in Chapter 4. The O-RAN Deployment Blueprint is used to further describe the O-RAN Deployment at the E2E System and Subsystem levels, and the Open Interfaces between the specified Subsystems. This would then allow definition and documentation of the testing methodology and the test cases using the Blueprint specification. + +![Figure 3-1: O-RAN Logical Architecture, Deployment Scenarios and Deployment Blueprints. This diagram shows three stacked blue parallelogram boxes. The top box is 'O-RAN Logical Architecture' with the subtitle 'Definitions of O-RAN Network functions and Interfaces'. The middle box is 'O-RAN Deployment Scenarios' with the subtitle 'Describes O-RAN network functions deployment variants as either PNF/VNF/CNF at different locations in the network'. The bottom box is 'O-RAN Deployment Blueprints' with the subtitle 'Specifies O-RAN Deployment at the E2E System and Subsystem levels and the Interfaces between the specified Subsystems'.](259e0e49e862fefad5badd9e00e33bb0_img.jpg) + +Figure 3-1: O-RAN Logical Architecture, Deployment Scenarios and Deployment Blueprints. This diagram shows three stacked blue parallelogram boxes. The top box is 'O-RAN Logical Architecture' with the subtitle 'Definitions of O-RAN Network functions and Interfaces'. The middle box is 'O-RAN Deployment Scenarios' with the subtitle 'Describes O-RAN network functions deployment variants as either PNF/VNF/CNF at different locations in the network'. The bottom box is 'O-RAN Deployment Blueprints' with the subtitle 'Specifies O-RAN Deployment at the E2E System and Subsystem levels and the Interfaces between the specified Subsystems'. + +Figure 3-1: O-RAN Logical Architecture, Deployment Scenarios and Deployment Blueprints + +## 3.1 O-RAN Logical Architecture + +Figure 3-2 shows the O-RAN logical architecture [3]. + +![Figure 3-2: Logical Architecture of O-RAN [3]. This block diagram shows the O-RAN architecture layers. At the top is the 'Service Management and Orchestration Framework' (purple) containing a 'Non-Real Time RIC' (green). Below it is the 'Near-Real Time RAN Intelligent Controller (RIC)' (blue). To the left is an 'O-eNB' (green). In the center are 'O-CU-CP' (yellow) and 'O-CU-UP' (yellow). At the bottom are 'O-DU' (red), 'O-RU' (red), and 'O-Cloud' (green). Interfaces are labeled: A1 (green) between Non-Real Time RIC and Near-Real Time RIC; E1 (green) between O-CU-CP and O-CU-UP; E2 (green) between O-eNB and Near-Real Time RIC; F1-c (green) between O-CU-CP and O-DU; F1-u (green) between O-CU-UP and O-DU. Open interfaces are shown on the right: X2-c, X2-u, NG-u, Xn-u, Xn-c, and NG-c. Open Fronthaul M-Plane and Open Fronthaul CUS-Plane are also indicated.](6920165771ff0f4446c12c22e3a3dd73_img.jpg) + +Figure 3-2: Logical Architecture of O-RAN [3]. This block diagram shows the O-RAN architecture layers. At the top is the 'Service Management and Orchestration Framework' (purple) containing a 'Non-Real Time RIC' (green). Below it is the 'Near-Real Time RAN Intelligent Controller (RIC)' (blue). To the left is an 'O-eNB' (green). In the center are 'O-CU-CP' (yellow) and 'O-CU-UP' (yellow). At the bottom are 'O-DU' (red), 'O-RU' (red), and 'O-Cloud' (green). Interfaces are labeled: A1 (green) between Non-Real Time RIC and Near-Real Time RIC; E1 (green) between O-CU-CP and O-CU-UP; E2 (green) between O-eNB and Near-Real Time RIC; F1-c (green) between O-CU-CP and O-DU; F1-u (green) between O-CU-UP and O-DU. Open interfaces are shown on the right: X2-c, X2-u, NG-u, Xn-u, Xn-c, and NG-c. Open Fronthaul M-Plane and Open Fronthaul CUS-Plane are also indicated. + +Figure 3-2: Logical Architecture of O-RAN [3] + +Refer to O-RAN WG1 “O-RAN Architecture Description” Technical Specification [3] for more details on the definitions for the O-RAN network functions and open interfaces. + +These O-RAN network functions and open interfaces are specified by different WGs in O-RAN Alliance. + +Table 3-1 shows the listing of the O-RAN network functions and the WGs which are responsible for specifications of the various aspects of these O-RAN network functions. + +**Table 3-1: O-RAN network functions and WGs responsible for specification** + +| O-RAN network function | O-RAN WG(s) | O-RAN WG focus | +|------------------------|-------------|---------------------------------------------------------------------------------------------| +| O-RU | WG1 | O1 management services | +| | WG4 | Open fronthaul CUS and M plane; Management Plane
O1 alignment work is in progress | +| | WG7 | Whitebox reference design | +| O-DU | WG1 | O1 management services | +| | WG3 | E2 node | +| | WG4 | Open fronthaul CUS and M plane; Management Plane | +| | WG5 | C and U-Plane profiles for F1
O1 information and data models | +| | WG6 | O-Cloud APIs (including AAL APIs) | +| | WG7 | Whitebox reference design | +| | WG8 | Reference Stack: O-DU Software Architecture and APIs | +| O-CU-CP | WG1 | O1 management services | +| | WG3 | E2 node | +| | WG5 | C-Plane profiles for X2, Xn, F1, E1
O1 information and data models | +| | WG6 | O-Cloud APIs (including AAL APIs) | +| | WG7 | Whitebox reference design | +| | WG8 | Reference Stack: O-CU-CP Software Architecture and APIs | +| O-CU-UP | WG1 | O1 management services | +| | WG3 | E2 node | +| | WG5 | U-Plane profiles for X2, Xn, F1
C-Plane profile for E1
O1 information and data models | +| | WG6 | O-Cloud APIs (including AAL APIs) | +| | WG7 | Whitebox reference design | +| | WG8 | Reference Stack: O-CU-UP Software Architecture and APIs | +| O-eNB | WG1 | O1 management services | +| | WG3 | E2 node | +| | WG4 | Open fronthaul CUS and M plane; Management Plane includes O1 alignment | +| | WG5 | C and U-Plane profiles for X2, Xn
O1 information and data models | +| | WG6 | O-Cloud APIs (including AAL APIs) | +| | WG7 | Whitebox reference design | +| O-Cloud | WG6 | O2
O-Cloud APIs (including AAL APIs) | +| Near-Real Time RIC | WG1 | O1 management services | + +| O-RAN network function | O-RAN WG(s) | O-RAN WG focus | +|-----------------------------------------------|-------------|--------------------------------------------------------| +| | WG3 | E2
xApp Open APIs
O1 information and data models | +| | WG6 | O-Cloud APIs (including AAL APIs) | +| SMO
(including Non-Real Time RIC function) | WG1 | O1 interface and common information/data models | +| | WG2 | A1 | + +Table 3-2 shows the listing of the O-RAN Open Interfaces and the WGs which are responsible for the specifications for these O-RAN open interfaces. + +**Table 3-2: O-RAN Open Interfaces and WGs responsible for specification** + +| O-RAN interfaces | O-RAN WG(s) | O-RAN WG focus | +|----------------------|-------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| A1 | WG2 | Specifies Control plane protocols for the logical interface between Non-RT-RIC function and near-RT-RIC function. | +| E1 | WG5 | 3GPP defined logical interface between gNB-CU-CP and gNB-CU-UP. O-RAN WG5 reuses and adopts these principles and protocol stack defined by 3GPP for the O-CU-CP and the O-CU-UP functions, as well as for the definition of interoperability profile specifications. | +| E2 | WG3 | Specifies Control plane protocols for the logical interface between near-RT-RIC function and E2 Nodes for E2 functions. | +| F1-C | WG5 | 3GPP defined logical interface between gNB-CU-CP and gNB-DU. O-RAN WG5 reuses and adopts these principles and protocol stack defined by 3GPP for the O-CU-CP and the O-DU functions, as well as for the definition of interoperability profile specifications. | +| F1-U | WG5 | 3GPP defined logical interface between gNB-CU-UP and gNB-DU. O-RAN WG5 reuses and adopts these principles and protocol stack defined by 3GPP for the O-CU-UP and the O-DU functions, as well as for the definition of interoperability profile specifications. | +| O1 | WG1 | Specifies Management plane interface between SMO and O-RAN Managed Element.

Noting that the Information and Data models for the O-RAN Managed Elements are specified by their respective WGs shown in Table 3-1. | +| O2 | WG6 | Specifies Management plane interface between SMO and O-Cloud. | +| Open Fronthaul (OFH) | WG4 | Specifies Open fronthaul interface between O-DU and O-RU includes Control, User, Synchronization and Management Planes. Management Planes include both Hierarchical and Hybrid modes.

Specifies Open fronthaul M-Plane between the O-RU and SMO for the O-RU configured in Hybrid mode. | +| X2-C | WG5 | 3GPP defined logical interface for transmitting control plane information between eNBs or between eNB and en-gNB in EN-DC deployment scenario. O-RAN WG5 reuses and adopts the principles and protocol stack defined by 3GPP for the definition of interoperability profile specifications. | +| X2-U | WG5 | 3GPP defined logical interface for transmitting user plane information between eNBs or between eNB and en-gNB in EN-DC deployment scenario. O-RAN WG5 reuses and adopts the principles and protocol stack defined by 3GPP for the definition of interoperability profile specifications. | + +| O-RAN interfaces | O-RAN WG(s) | O-RAN WG focus | +|------------------|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Xn-C | WG5 | 3GPP defined logical interface for transmitting control plane information between gNBs, ng-eNBs or between eNB and ng-gNB. O-RAN WG5 reuses and adopts the principles and protocol stack defined by 3GPP for the definition of interoperability profile specifications. | +| Xn-U | WG5 | 3GPP defined logical interface for transmitting user plane information between gNBs, ng-eNBs or between eNB and ng-gNB. O-RAN WG5 reuses and adopts the principles and protocol stack defined by 3GPP for the definition of interoperability profile specifications. | + +1 + +2 + +## 3.2 O-RAN Cloud Deployment Scenarios + +3 + +4 + +5 + +This section gives a short introduction to each of the O-RAN Cloud Deployment Scenarios abstracted from inputs O-RAN Alliance have received from global operators which have gathered the most interest and are of either current or relatively near-term interest that can be supported by the O-RAN specifications. + +6 + +7 + +8 + +The key differences between these Cloud Deployment Scenarios are highlighted given that these are important factors to be taken into considerations when designing the O-RAN Deployment Blueprint template and the E2E testing methodologies in the next chapters of this specification. + +9 + +10 + +Refer to O-RAN WG6 “Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN” Technical Report [4] for more details. + +11 + +12 + +Figure 3-3 shows a high-level comparison of O-RAN Cloud Deployment Scenarios for NR Standalone (SA) operation [4]. + +![Figure 3-3: High Level Comparison of O-RAN Cloud Deployment Scenarios. The diagram illustrates six scenarios (A through F) showing the distribution of O-RAN network functions (NFs) across different cloud environments (Regional Cloud, Edge Cloud, Cell Site) and physical network functions (PNFs). Scenario A shows a centralized O-Cloud in the Regional Cloud. Scenario B shows O-Cloud in both Regional and Edge Clouds. Scenario C shows O-Cloud in Regional Cloud and O-Cloud in Edge Cloud. Scenario C.1 & C.2 show O-Cloud in Regional Cloud and O-Cloud in Edge Cloud. Scenario D shows O-Cloud in Regional Cloud and O-RAN Physical NF in Edge Location. Scenario E shows O-Cloud in Regional Cloud and O-Cloud in Cell Site. Scenario F shows O-Cloud in Regional Cloud and O-Cloud in Edge Cloud. The diagram also shows the O-RAN Physical NF in Cell Site. A key explains the notation: 'O-Cloud' indicates an O-RAN Cloud Platform is used to support the RAN functions. This will use hardware accelerator add-ons as required by each RAN function, and the software stack is decoupled from the hardware. Each O-Cloud uses open interfaces. Network Functions (e.g., O-CU + O-DU) are shown in blue boxes. O-Cloud is shown in light blue boxes. O-RAN Physical NF is shown in dark blue boxes. A note states: 'Could be 100% O-RAN Physical NF (potentially in an open chassis). Uses Open interfaces.'](bd4e5e15cc89e678a9da145b30032e05_img.jpg) + +Figure 3-3: High Level Comparison of O-RAN Cloud Deployment Scenarios. The diagram illustrates six scenarios (A through F) showing the distribution of O-RAN network functions (NFs) across different cloud environments (Regional Cloud, Edge Cloud, Cell Site) and physical network functions (PNFs). Scenario A shows a centralized O-Cloud in the Regional Cloud. Scenario B shows O-Cloud in both Regional and Edge Clouds. Scenario C shows O-Cloud in Regional Cloud and O-Cloud in Edge Cloud. Scenario C.1 & C.2 show O-Cloud in Regional Cloud and O-Cloud in Edge Cloud. Scenario D shows O-Cloud in Regional Cloud and O-RAN Physical NF in Edge Location. Scenario E shows O-Cloud in Regional Cloud and O-Cloud in Cell Site. Scenario F shows O-Cloud in Regional Cloud and O-Cloud in Edge Cloud. The diagram also shows the O-RAN Physical NF in Cell Site. A key explains the notation: 'O-Cloud' indicates an O-RAN Cloud Platform is used to support the RAN functions. This will use hardware accelerator add-ons as required by each RAN function, and the software stack is decoupled from the hardware. Each O-Cloud uses open interfaces. Network Functions (e.g., O-CU + O-DU) are shown in blue boxes. O-Cloud is shown in light blue boxes. O-RAN Physical NF is shown in dark blue boxes. A note states: 'Could be 100% O-RAN Physical NF (potentially in an open chassis). Uses Open interfaces.' + +13 + +14 + +**Figure 3-3: High Level Comparison of O-RAN Cloud Deployment Scenarios [4]** + +15 + +16 + +Few notes for clarification purposes on the O-RAN network functions and interfaces shown in Figure 3-3 and for the remaining of this section. + +17 + +18 + +19 + +20 + +21 + +22 + +23 + +24 + +25 + +1. The O-CU and vO-CU referred in [4] should be considered as O-CU CP/UP and vO-CU CP/UP, respectively. +2. O-RAN deployments with all Physical Network Function (PNF) based implementation may exist but are not shown in this figure as this figure shows cloud deployment scenarios with at least one O-RAN network function implemented on the O-Cloud. +3. O-RAN deployments with PNF instead of VNF/CNF based implementation may exist but are not shown in this figure such as Scenario E with O-DU and O-RU implemented as PNFs (instead of VNF/CNF) at the Cell Site. +4. Not all the O-RAN network functions and interfaces defined by O-RAN Alliance are shown in Figure 3-3. For example, the Non-Real Time RIC, SMO, O-CU-CP, O-CU-UP, O-eNB are not shown in this figure. + +### NR Standalone (SA) + +1. **(SA) Scenario A** shows the near-RT RIC, O-CU, and O-DU network functions virtualized and co-located on the same Edge Cloud platform. The O-RU deployed at the Cell site is not virtualized. +2. **(SA) Scenario B** is similar to (SA) Scenario A, the only difference is that the Near-Real Time RIC in (SA) Scenario B is deployed on the Cloud Platform at the Regional cloud (as compared to the Edge cloud in (SA) Scenario A). +3. **(SA) Scenario C** shows near-RT RIC, O-CU are virtualized on the same Regional Cloud platform and the O-DU virtualized on an Edge Cloud platform +4. **(SA) Scenario C.1** shows a deployment variant of (SA) Scenario C adding the flexibility to be able to deploy parts of the O-CU-UP in the Edge Cloud platform in order to better support use cases such as differentiated performance requirements of the traffic types and network slices. +5. **(SA) Scenario C.2** shows a deployment variant of (SA) Scenario C adding the flexibility to be able to deploy additional O-DUs and O-CUs in the Edge Cloud platform to better support use cases such as differentiated performance requirements of the traffic types, network slices and RAN sharing. +6. **(SA) Scenario D** shows a deployment variant of (SA) Scenario C, but in this case the O-DU functionality is supported by an O-RAN PNF rather than an O-Cloud. +7. **(SA) Scenario E** shows a future state scenario assuming that the O-RU can be successfully virtualized and deployed with the O-DU in the same O-Cloud platform located at the Cell site. Near-RT RIC and O-CU are virtualized on the same Regional Cloud platform. +8. **(SA) Scenario F** shows a future state scenario assuming that the O-RU can be successfully virtualized and deployed in the O-Cloud platform located at the Cell Site. The near-RT RIC, O-CU are virtualized on the same Regional Cloud platform and the O-DU virtualized on an Edge Cloud platform. + +### NR Non-Standalone (NSA) + +The following listed (NSA) Cloud Deployment scenarios are similar to the (SA) Cloud Deployment scenarios above listed with the LTE network functions (O-CU, O-DU) co-located with the NR network functions (O-CU, O-DU). + +1. **(NSA) Scenario A** is similar to (SA) Scenario A with the addition of LTE network functions (O-CU, O-DU) virtualized and co-located on the same Edge Cloud platform as the NR network functions (O-CU, O-DU). +2. **(NSA) Scenario B** is similar to (SA) Scenario B with the addition of LTE network functions (O-CU, O-DU) virtualized and co-located on the same Edge Cloud platform as the NR network functions (O-CU, O-DU). +3. **(NSA) Scenarios C, C.2** are similar to (SA) Scenario C, C.2 with the addition of LTE network function(s) (O-CU) virtualized and co-located on the same Regional Cloud platform as the NR network function(s) (O-CU). The LTE network function(s) (O-DU) virtualized and co-located on the same Edge Cloud platform as the NR network function(s) (O-DU). +4. **(NSA) Scenario D** is similar to (SA) Scenario D with the addition of LTE network function(s) (O-CU) virtualized and co-located on the same Edge Cloud platform as the NR network function(s) (O-CU). The LTE network function(s) (O-DU) is non-virtualized and co-located at the same Edge location as the NR network function(s) (O-DU). + +Figures 3-4 and 3-5 show the Cloud Deployment Scenarios B from [4] for NR Standalone (SA) and Non-Standalone (NSA) operations, respectively. Refer to Annex D in this document for additional Cloud Deployment Scenarios figures. + +Refer to [4] for the definitions and more details on the GW (Opt) node, RU, vO-CU, vO-DU shown in these figures. Refer to [5] for the Cloud Platform Reference Design for Deployment Scenario B. + +![Figure 3-4: Cloud Deployment Scenario B for SA operation. The diagram shows a multi-tier cloud architecture. On the left, the 'Regional cloud' contains a 'UPF, MEC' block. In the center, the 'Edge cloud' contains a 'Near-RT RIC' and 'Cloud Platform' block, and a 'vO-CU' and 'vO-DU' block, both labeled 'Open chassis and blade spec'. On the right, the 'Cell site' contains an 'O-RU (/RU)' block. Connections: A red arrow points from the 'UPF, MEC' to the 'vO-CU'. A dashed line labeled '1:L E2 E2' connects the 'Near-RT RIC' to the 'vO-CU'. A dashed line labeled 'F1' connects the 'vO-CU' to the 'vO-DU'. A dashed line labeled '1:N' connects the 'vO-DU' to the 'O-RU (/RU)'. A dashed line labeled 'Open fronthaul' connects the 'vO-DU' to the 'O-RU (/RU)'. A dashed line labeled 'GW (Opt)' is shown between the 'vO-DU' and the 'O-RU (/RU)'.](a86181562e07b63d9ceb5af4373a63cb_img.jpg) + +Figure 3-4: Cloud Deployment Scenario B for SA operation. The diagram shows a multi-tier cloud architecture. On the left, the 'Regional cloud' contains a 'UPF, MEC' block. In the center, the 'Edge cloud' contains a 'Near-RT RIC' and 'Cloud Platform' block, and a 'vO-CU' and 'vO-DU' block, both labeled 'Open chassis and blade spec'. On the right, the 'Cell site' contains an 'O-RU (/RU)' block. Connections: A red arrow points from the 'UPF, MEC' to the 'vO-CU'. A dashed line labeled '1:L E2 E2' connects the 'Near-RT RIC' to the 'vO-CU'. A dashed line labeled 'F1' connects the 'vO-CU' to the 'vO-DU'. A dashed line labeled '1:N' connects the 'vO-DU' to the 'O-RU (/RU)'. A dashed line labeled 'Open fronthaul' connects the 'vO-DU' to the 'O-RU (/RU)'. A dashed line labeled 'GW (Opt)' is shown between the 'vO-DU' and the 'O-RU (/RU)'. + +**Figure 3-4: Cloud Deployment Scenario B for SA operation [4]** + +![Figure 3-5: Cloud Deployment Scenario B for NSA operation [4]. The diagram illustrates a multi-tier cloud architecture. On the left, a 'Regional cloud' contains a 'Near-RT RIC' and a 'Cloud Platform'. It connects via 'E2' interfaces (1:L, E2, E2) to an 'Edge cloud'. The 'Edge cloud' contains 'vO-CU_N', 'vO-DU_N', 'vO-CU_E', and 'vO-DU_E' functions, along with an 'O-eNB' and a 'Cloud Platform'. These are connected via 'Xn' and 'F1' interfaces. The 'Edge cloud' connects via 'Open fronthaul' (1:N) to 'Cell site' components: 'O-RU_N (/RU_N)' and 'O-RU_E (/RU_E)', which are connected via 'GW (Opt)' interfaces. A note indicates '(*) for ng-eNB only'.](5404f6eae2b2e63d42620574e82bfb20_img.jpg) + +Figure 3-5: Cloud Deployment Scenario B for NSA operation [4]. The diagram illustrates a multi-tier cloud architecture. On the left, a 'Regional cloud' contains a 'Near-RT RIC' and a 'Cloud Platform'. It connects via 'E2' interfaces (1:L, E2, E2) to an 'Edge cloud'. The 'Edge cloud' contains 'vO-CU\_N', 'vO-DU\_N', 'vO-CU\_E', and 'vO-DU\_E' functions, along with an 'O-eNB' and a 'Cloud Platform'. These are connected via 'Xn' and 'F1' interfaces. The 'Edge cloud' connects via 'Open fronthaul' (1:N) to 'Cell site' components: 'O-RU\_N (/RU\_N)' and 'O-RU\_E (/RU\_E)', which are connected via 'GW (Opt)' interfaces. A note indicates '(\*) for ng-eNB only'. + +**Figure 3-5: Cloud Deployment Scenario B for NSA operation [4]** + +Noting that all the Cloud Deployment Scenarios listed in [4] use the same set of O-RAN network functions and Open interfaces, while the key differences are with the + +1. Use Cases and Services Requirements (e.g. network slicing, bandwidth, latency, reliability etc.). +2. Network design considerations (e.g. transport capabilities such capacity, latency between Cell site, Edge and Regional cloud, operating spectrum bands etc.). +3. NR deployment modes – SA, NSA. +4. Network functions – Physical, Virtual, Cloudified implementation (e.g. taking into considerations O-Cloud solution availability with certain timeframes in mind). +5. Co-locations of the various O-RAN network functions (e.g. vO-CU, vO-DU at the Edge Cloud in Scenario B). +6. Co-located O-RAN network functions may be deployed as Integrated or Separated nodes. +7. O-RAN network functions shown are logical functions which in deployment scenarios where more than a single O-RAN network functions are co-located, can be either implemented as an integrated Subsystem (combined vO-CU and vO-DU at the Edge Cloud in Scenario B) or independent Subsystems (separate vO-CU and vO-DU at the Edge Cloud in Scenario B). Refer to Chapter 4 for the definition of the Subsystem. +8. Locations of the O-RAN network functions at the Cell site, Edge cloud, Regional cloud. + +# Chapter 4 O-RAN Deployment Blueprints + +## 4.1 Introduction + +This chapter provides the high-level definition of the O-RAN Deployment Blueprint template which contains the necessary descriptors to build the underlying O-RAN Deployment Blueprints. + +The O-RAN Deployment Blueprint is defined as the set of inputs used to describe a specific O-RAN deployment from several aspects. These aspects include the specification of the O-RAN deployment at the System level (e.g. architecture, performance metrics) as well as Subsystem level and the Open Interfaces between the specified Subsystems. This would then allow definition and documentation of the testing methodology and the test cases using the blueprint specification. + +Each of the O-RAN Deployment Blueprints can be described with + +1. A single System Profile +2. Two or more Subsystem Instance Profiles +3. One or more Subsystem Pair Interoperability Profile(s) + +Figure 4-1 shows the relationship between Deployment Blueprint and its associated set of Profiles. + +![Figure 4-1: Deployment Blueprint and the associated Profiles. The diagram shows a hierarchy where multiple Use Cases (Use Case #1, Use Case #2, ..., Use Case #n) each contain a Deployment Blueprint (Deployment Blueprint #1, Deployment Blueprint #2, ..., Deployment Blueprint #n). These blueprints are associated with a central System Profile. The System Profile is further associated with two types of profiles: Subsystem Instance Profile (which has a reference to WG Subsystem Technical and Test specifications) and Subsystem Pair Interoperability Profile (which has a reference to WG Interface Technical and Test specifications). The System Profile also includes E2E Test Methodology, Test Cases and KPIs.](f86354091231e648768ce7c0ab343658_img.jpg) + +``` + +graph TD + subgraph UC1 [Use Case #1] + DB1[Deployment Blueprint #1] + end + subgraph UC2 [Use Case #2] + DB2[Deployment Blueprint #2] + end + subgraph UCn [Use Case #n] + DBn[Deployment Blueprint #n] + end + DB1 --- SP[System Profile] + DB2 --- SP + DBn --- SP + SP --- E2E[E2E Test Methodology, Test Cases and KPIs] + SP --- SIP[Subsystem Instance Profile] + SP --- SPIP[Subsystem Pair Interoperability Profile] + SIP -.- SIP_Spec[Reference to WG Subsystem Technical and Test specifications] + SPIP -.- SPIP_Spec[Reference to WG Interface Technical and Test specifications] + SIP -.- SPIP + +``` + +Figure 4-1: Deployment Blueprint and the associated Profiles. The diagram shows a hierarchy where multiple Use Cases (Use Case #1, Use Case #2, ..., Use Case #n) each contain a Deployment Blueprint (Deployment Blueprint #1, Deployment Blueprint #2, ..., Deployment Blueprint #n). These blueprints are associated with a central System Profile. The System Profile is further associated with two types of profiles: Subsystem Instance Profile (which has a reference to WG Subsystem Technical and Test specifications) and Subsystem Pair Interoperability Profile (which has a reference to WG Interface Technical and Test specifications). The System Profile also includes E2E Test Methodology, Test Cases and KPIs. + +**Figure 4-1: Deployment Blueprint and the associated Profiles** + +## 4.2 System Profiles + +The purpose of the System Profile is to describe the O-RAN Deployment Blueprint from the E2E system perspective. + +A **System Profile** consists of **System Architecture information** and a set of **System Profile parameters**. + +Figure 4-2 shows the scope of the System Profile in relation to the O-RAN Deployment Blueprint. + +![Figure 4-2: Scope of the System Profile in relation to the Deployment Blueprint. The diagram shows a system architecture within a blue-bordered box. At the top left is the SMO (Service Management Orchestrator). Below it are two WG4 M-Plane (Hybrid) / O1 blocks. In the center is the FHM (Optional) block. To the right is the Non-Real Time RIC and Near-Real Time RIC (containing xApps). Below these are the O-RU, O-DU, and O-CU-CP, O-CU-UP blocks. At the bottom is the O-Cloud. A Transport as a Service (xHaul) block is at the bottom left. Interfaces are labeled: WG4 M-Plane (Hybrid) / O1, OFH1, OFH2, O1, A1, E2, F1, and O2. A legend at the bottom left states: 'The circles at both ends of each line indicate the endpoints of each interface'. A legend at the bottom right states: '1 CUS-Plane, 2 M-Plane (Hierarchical)'.](de74b39b3a82582e4c88109e05a3ff4b_img.jpg) + +**1 System Profile** + +●—● The circles at both ends of each line indicate the endpoints of each interface + +1 CUS-Plane +2 M-Plane (Hierarchical) + +Figure 4-2: Scope of the System Profile in relation to the Deployment Blueprint. The diagram shows a system architecture within a blue-bordered box. At the top left is the SMO (Service Management Orchestrator). Below it are two WG4 M-Plane (Hybrid) / O1 blocks. In the center is the FHM (Optional) block. To the right is the Non-Real Time RIC and Near-Real Time RIC (containing xApps). Below these are the O-RU, O-DU, and O-CU-CP, O-CU-UP blocks. At the bottom is the O-Cloud. A Transport as a Service (xHaul) block is at the bottom left. Interfaces are labeled: WG4 M-Plane (Hybrid) / O1, OFH1, OFH2, O1, A1, E2, F1, and O2. A legend at the bottom left states: 'The circles at both ends of each line indicate the endpoints of each interface'. A legend at the bottom right states: '1 CUS-Plane, 2 M-Plane (Hierarchical)'. + +**Figure 4-2: Scope of the System Profile in relation to the Deployment Blueprint** + +Note that the intent of Figure 4-2 is used to show the scope of the System Profile in relation to the Deployment Blueprint. It is not intending to show the actual O-RAN network functions and open interfaces which must be included in the System Profile for all the O-RAN Deployment Blueprints. + +OFH indicated in Figure 4-2 includes WG4 CUS and M plane implementation and for M-Plane both the Hierarchical and Hybrid models. Refer to [6][7] for more details. + +**System Architecture Information** shall include an Architecture diagram which is used to describe the Network and Network Slices Topology which consists of the + +1. Subsystems involved +2. Type of implementation of each Subsystem (e.g. as a Physical (PNF), Virtual (VNF) or Cloud-Native Network Function (CNF)) +3. Location where each of the Subsystems are expected to be deployed (e.g. Cell site, Edge site, Regional site, Core/Central site as appropriate) +4. Interconnections and Cardinality between the Subsystems + +The intent of this specification is to make references as much as possible to the list of Deployment Scenarios documented in O-RAN WG6 “Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN” Technical Report [4]. + +Figure 3-4 shows an example of the System Architecture Diagram for Cloud Scenario B referenced from [4]. + +It should be noted that there can be O-RAN Deployment Blueprints which may be designed for deployment scenarios currently not specified in [4]. Examples can be an all PNF based O-RAN deployment, Non-Standalone (NSA) O-RAN deployment, different xApps implementation among others. + +In addition to specifying the System Architecture diagram and information, it would be useful to specify the following listed **System Profiles parameters** which are used to describe the System level requirements for the Blueprints. + +1. Services Requirements (e.g. eMBB, URLLC, mMTC, combinations of these) +2. Use Cases (e.g. 3GPP use cases such as VoLTE/VoNR, O-RAN RIC-enabled use cases such as Traffic Steering, QoE Optimization, Massive MIMO Beamforming Optimization, RAN Sharing among others – refer to [8] for more details) +3. Use Cases E2E Performance requirements of the Application, Services (e.g. data rate, latency, reliability, availability, deterministic networking including transmission latency etc.) +4. Indoor or Outdoor deployment +5. Radio Access Technologies (RAT) Types (e.g. 4G LTE/5G NR) +6. 5G NR Deployment Options and Evolution (options of Standalone SA, Non-Standalone NSA) +7. Spectrum Bands and Duplex Modes for 4G LTE/5G NR +8. Cell Types (e.g. Macro, Micro, Pico, others) + +9. Network and Network Slices Topology needing to include Cardinality, Network functions (xNFs), Transport (T-plane), Timing and Sync (S-Plane), Management (M Plane, MANO, SMO) +10. E2E Network Performance requirements of the RAN Network Functions, Slices and Management KPIs + +## 4.3 Subsystem Instance Profiles + +Each of the Subsystem in the Deployment Blueprint can be described with its **Subsystem Instance Profile**. + +Figure 4-3 shows the scope of the Subsystem Instance Profile in relation to the O-RAN Deployment Blueprint. + +![Figure 4-3: Scope of the Subsystem Instance Profile in relation to the Deployment Blueprint. The diagram shows a System Profile (1) containing various Subsystem Instance Profiles (2). These include SMO, Non-Real Time RIC, Near-Real Time RIC (xApps), O-RU, FHM, O-DU, O-CU-CP, O-CU-UP, and O-Cloud. Interfaces like WG4, OFH1, OFH2, O1, A1, E2, F1, and O2 are shown connecting these profiles. A legend indicates that circles at the ends of lines represent interface endpoints.](196fa23217272842f4fad36db8c56381_img.jpg) + +1 System Profile + +2 Subsystem Instance Profile e.g. SMO + +Subsystem Instance Profile e.g. Non-Real Time RIC + +WG4 M-Plane (Hybrid) / O1 + +WG4 M-Plane (Hybrid) + +O1 + +A1 + +O1 + +O1 + +O2 + +Subsystem Inst. Profile e.g. Near-Real Time RIC + +xApps + +E2 + +F1 + +E2 + +Subsystem Instance Profile e.g. O-RU + +OFH1 + +OFH2 + +OFH1 + +OFH2 + +Subsystem Inst. Profile e.g. FHM + +Subsystem Instance Profile e.g. O-DU + +Subsystem Inst. Profile e.g. O-CU-CP, O-CU-UP + +O-Cloud API + +Subsystem Instance Profile e.g. O-Cloud + +Transport as a Service (xHaul) Subsystem Instance Profile + +1 CUS-Plane +2 M-Plane (Hierarchical) + +●—● The circles at both ends of each line indicate the endpoints of each interface + +Figure 4-3: Scope of the Subsystem Instance Profile in relation to the Deployment Blueprint. The diagram shows a System Profile (1) containing various Subsystem Instance Profiles (2). These include SMO, Non-Real Time RIC, Near-Real Time RIC (xApps), O-RU, FHM, O-DU, O-CU-CP, O-CU-UP, and O-Cloud. Interfaces like WG4, OFH1, OFH2, O1, A1, E2, F1, and O2 are shown connecting these profiles. A legend indicates that circles at the ends of lines represent interface endpoints. + +**Figure 4-3: Scope of the Subsystem Instance Profile in relation to the Deployment Blueprint** + +Note that the intent of Figure 4-3 is used to show the scope of the Subsystem Instance Profile in relation to the O-RAN Deployment Blueprint. It is not intending to show the actual Subsystem Instance Profiles which must be included for all the O-RAN Deployment Blueprints. + +OFH indicated in Figure 4-3 includes WG4 CUS and M plane implementation and for M-Plane both the Hierarchical and Hybrid models. Refer to [6][7] for more details. + +A **Subsystem Instance** is defined to uniquely identify different implementations of a **Subsystem Type**. + +For example, two O-RUs belonging to the **same Subsystem Type** (O-RU) which are optimally designed for Indoors versus Outdoors macro deployment scenarios will be considered as **different Subsystem Instances** as they would have different sets of capabilities and requirements defined for their respective purposes and therefore needing to be tested based on their respective sets of capabilities, requirements and KPIs. + +The **Subsystem Instance Profile** is therefore dependent on the **Subsystem Type**. + +The Subsystem Instance Profile should be specified to include the following information as defined in available technical and test specifications. + +1. Features and capabilities +2. Functional specifications +3. Performance specifications (e.g. O-RU and O-DU sensitivity, QAM utilization, Spectral efficiency among others) +4. Performance measurements – Parameters with optional nominal values + +### 4.3.1 Relationship between Subsystem Type and O-RAN network functions + +![Diagram showing the relationship between Subsystem Type and O-RAN Network Functions. A box labeled 'Subsystem Type' is connected to a box labeled 'O-RAN Network Functions' by a line. Above the line is 'M:N', below the line is 'M>=1' and 'N>=1'.](e73ed7c944b9c3dc5e974a1d518a7a7d_img.jpg) + +``` + +graph LR + A[Subsystem Type] ---| "M:N +M>=1 +N>=1" | B[O-RAN Network Functions] + +``` + +Diagram showing the relationship between Subsystem Type and O-RAN Network Functions. A box labeled 'Subsystem Type' is connected to a box labeled 'O-RAN Network Functions' by a line. Above the line is 'M:N', below the line is 'M>=1' and 'N>=1'. + +**Figure 4-4: Relationship between Subsystem Type and O-RAN Network Functions** + +The **Subsystem Type** is defined as the most fundamental building block / module of the O-RAN Deployment Blueprint which require robust interoperability testing as a Subsystem Instance in the O-RAN E2E testing framework. Therefore, the Subsystem Types may be different for different O-RAN Deployment Blueprints. + +The relationship between Subsystem Type and O-RAN network functions can be described with the following scenarios + +- Scenario 1: A single Subsystem Type composed with a single O-RAN network function ( $M=N=1$ ) +- Scenario 2: A single Subsystem Type composed with more than a single O-RAN network function ( $M=1, N>1$ ) +- Scenario 3: A single O-RAN network function maps to more than a single Subsystem Type ( $M>1, N=1$ ) + +| Subsystem Type | O-RAN network function | Comments | +|--------------------|------------------------|----------| +| O-Cloud | O-Cloud | | +| Near-Real Time RIC | Near-Real Time RIC | | +| Non-Real Time RIC | Non-Real Time RIC | | +| SMO | SMO | | + +**Table 4-2: Relationship of Subsystem Type to the O-RAN network functions (M=1, N>1)** + +| Subsystem Type | O-RAN network functions | Reference to [4] as appropriate | +|-------------------------------------------------|--------------------------------------|----------------------------------------------------------------------------------------------------------------------------| +| Integrated O-CU-CP, O-CU-UP [NR] | O-CU-CP, O-CU-UP | Integrated O-CU-CP, O-CU-UP can be implemented as a Subsystem composed of O-CU-CP, O-CU-UP as shown in Scenarios A, B etc. | +| Integrated O-RU, O-DU [NR / LTE] | O-RU, O-DU | O-RU, O-DU can be implemented as a single Subsystem as shown in Scenario E for NR. | +| Integrated O-DU, O-CU-CP, O-CU-UP [NR] | O-DU, O-CU-CP, O-CU-UP | O-DU, O-CU-CP, O-CU-UP can be implemented as a single Subsystem as shown in Scenarios A, B etc. | +| Integrated O-CU-CP, O-CU-UP, Near-Real Time RIC | O-CU-CP, O-CU-UP, Near-Real Time RIC | Near-Real Time RIC, O-CU-CP, O-CU-UP can be implemented as a single Subsystem as shown in Scenario C etc. | +| O-eNB [LTE] | O-RU, O-DU, CU | O-eNB can be implemented as a single O-RAN network function (O-eNB) or composed with LTE O-RU, O-DU, CU. | + +**Table 4-3: Relationship of Subsystem Type to the O-RAN network functions (M>1, N=1)** + +| Subsystem Type | O-RAN network function | Comments | +|---------------------------------------------------------------------|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Hardware Accelerator with Acceleration Abstraction Layer (AAL) APIs | O-Cloud | Hardware Accelerator with Open API allowing NFs applications to discover, configure, select and use (one or more) acceleration functions provided by a given accelerator on the cloud platform. | +| xApps | Near-Real Time RIC | The xApp is designed to run on the near-RT RIC which provides Open APIs for A1, E2, Management, Control and Shared Data Layer (SDL). | +| O-DU L1 stack | O-DU | High Physical layer (L1) stack in O-DU which provides API's to communicate with MAC Layer (L2) stack of O-DU. | +| O-DU L2 stack | O-DU | MAC Layer (L2) stack in O-DU which provides API's to communicate with High Physical Layer (L1) stack and RLC Layer stack of O-DU. | + +## 4.4 Subsystem Pair Interoperability Profiles + +Each pair of Subsystem Instances and the Open Interface between them can be described in the O-RAN Deployment Blueprint with its Subsystem Pair Interoperability Profile. + +Figure 4-5 shows the scope of the Subsystem Pair Interoperability Profile in relation to the O-RAN Deployment Blueprint. + +![Figure 4-5: Scope of the Subsystem Pair Interoperability Profile in relation to the Deployment Blueprint. The diagram shows a system profile with various components and their interconnections. Key components include SMO, Non-Real Time RIC, Near-Real Time RIC, xApps, xApp API, O-RU, FHM (Optional), O-DU, O-CU-CP, O-CU-UP, O-Cloud, and Transport as a Service (xHaul). Interfaces are labeled with codes like WG4, O1, O2, A1, E2, F1, OFH1, OFH2. A legend indicates that circles at the ends of lines represent interface endpoints. A note at the bottom right specifies: 1 CUS-Plane, 2 M-Plane (Hierarchical).](e8aa6bf8bc13ebc796dc47cd4ac643d8_img.jpg) + +●—● The circles at both ends of each line indicate the endpoints of each interface + +1 CUS-Plane +2 M-Plane (Hierarchical) + +Figure 4-5: Scope of the Subsystem Pair Interoperability Profile in relation to the Deployment Blueprint. The diagram shows a system profile with various components and their interconnections. Key components include SMO, Non-Real Time RIC, Near-Real Time RIC, xApps, xApp API, O-RU, FHM (Optional), O-DU, O-CU-CP, O-CU-UP, O-Cloud, and Transport as a Service (xHaul). Interfaces are labeled with codes like WG4, O1, O2, A1, E2, F1, OFH1, OFH2. A legend indicates that circles at the ends of lines represent interface endpoints. A note at the bottom right specifies: 1 CUS-Plane, 2 M-Plane (Hierarchical). + +**Figure 4-5: Scope of the Subsystem Pair Interoperability Profile in relation to the Deployment Blueprint** + +Note that the intent of Figure 4-5 is used to show the scope of the Subsystem Pair Interoperability Profile in relation to the O-RAN Deployment Blueprint. It is not intending to show the actual Subsystem Pair Interoperability Profile(s) which must be included for all the O-RAN Deployment Blueprints. + +OFH indicated in Figure 4-5 includes WG4 CUS and M plane implementation and for M-Plane both the Hierarchical and Hybrid models. Refer to [6][7] for more details. + +The Subsystem Pair Interoperability Profile is dependent on the pair of Subsystem Instances which are connected via an **Interface under Test (IUT)**. + +**Subsystem Pair Interoperability Profile** defined in the O-RAN Deployment Blueprint includes the Interoperability Test (IOT) Profile for a specific Open Interface implementation between two Subsystem Instances. + +The Subsystem Pair Interoperability Profile should be specified to include the following information as defined in available O-RAN WGs technical and test specifications + +1. Features and capabilities +2. Functional specifications +3. Performance specifications +4. Performance measurements – Parameters with optional nominal values + +Table 4-4 shows the mapping of Subsystem Pair Interoperability Profile to the respective O-RAN WGs. + +**Table 4-4: Subsystem Pair Interoperability Profile and respective O-RAN WGs** + +| Subsystem Pair Interoperability Profiles | O-RAN WG(s) | O-RAN WG focus | +|------------------------------------------|-------------|---------------------------------------------------------------------------------------------------------| +| Open Fronthaul (OFH) | WG4 | WG4 IOT profiles C/U/S/M Planes | +| X2 | WG5 | WG5 C and U Plane Profiles | +| Xn | WG5 | WG5 C and U Plane Profiles | +| E1 | WG5 | WG5 C Plane Profiles (currently not available)
Note: E1 not supported by existing WG5 specifications | +| F1-C/F1-U | WG5 | WG5 C and U Plane Profiles | +| E2 | WG3 | | +| A1 | WG2 | | + +| Subsystem Pair
Interoperability Profiles | O-RAN WG(s) | O-RAN WG focus | +|---------------------------------------------|-------------|--------------------| +| O1 | WG1 | | +| O2 | WG6 | | +| xApp (Near-RT RIC) | WG3 | Open APIs for xApp | +| AAL | WG6 | | + +1 + +2 + +# Chapter 5 O-RAN End-to-End (E2E) Testing Framework + +This chapter describes the E2E testing methodology for the holistic testing and evaluation of the O-RAN Deployment Blueprints ensuring that these Blueprints can be robustly tested and optimized, ensuring consistent high quality and performance in a deterministic, repeatable and reproducible manner across the entire technology lifecycle. + +Figure 5-1 shows the major phases of the technology lifecycle which will require testing and optimization. + +In this version of the specification, the focus will be on the Lab Verification phase. + +![Figure 5-1: Major Stages of the Technology Lifecycle. The diagram illustrates a continuous cycle of six stages: 5G Field Validation (checkmark icon), 5G Assurance and Optimization (network diagram icon), 5G Scaling Up (bar chart icon), 5G Field Deployment and Turn Up (truck icon), New 5G Features Development (ruler and pencil icon), and 5G Lab System Verification (wrench and screwdriver icon). Arrows connect these stages in a clockwise direction, forming a continuous loop.](06cc03130b7521e6d612848328058971_img.jpg) + +Figure 5-1: Major Stages of the Technology Lifecycle. The diagram illustrates a continuous cycle of six stages: 5G Field Validation (checkmark icon), 5G Assurance and Optimization (network diagram icon), 5G Scaling Up (bar chart icon), 5G Field Deployment and Turn Up (truck icon), New 5G Features Development (ruler and pencil icon), and 5G Lab System Verification (wrench and screwdriver icon). Arrows connect these stages in a clockwise direction, forming a continuous loop. + +**Figure 5-1: Major Stages of the Technology Lifecycle** + +The proposed testing methodology involves Subsystem testing, Subsystem Pairing and Open Interfaces Interoperability testing and E2E System testing. + +## 5.1 Stages and Sequence of Testing + +Figure 5-2 shows the stages and sequence of testing which can be performed on the O-RAN Deployment Blueprint + +1. Perform Subsystem Testing on each of the Subsystems defined in the Blueprint +2. Perform Interoperability testing with pairs of Subsystems which have passed the Subsystem Testing stage +3. Perform E2E System Testing after all Subsystem Pairs passed the Subsystem Pair Interoperability Testing stage + +![Figure 5-2: Stages and Sequence of Testing to be performed on the O-RAN Deployment Blueprint. The diagram shows a vertical flow of three testing stages, each with a corresponding description box. A large blue arrow on the left points upwards and is labeled 'Test Automation'.](a0129d2fd175a79700e27a15ed7707d3_img.jpg) + +| Test Stage | Description | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1. Subsystem Testing | Testing for All Subsystems defined in the O-RAN Deployment Blueprint
Testing is performed with the corresponding O-RAN Subsystem Instance Profile, Test Cases, Performance Measurements and KPIs defined in the O-RAN Subsystem Instance Profile and in accordance to the O-RAN Deployment Blueprint. | +| 2. Subsystem Pair Testing | Testing for All Subsystem Pairs defined in the O-RAN Deployment Blueprint
Testing is performed with the corresponding O-RAN Subsystem Pair Interoperability Profile, Test Cases, Performance Measurements and KPIs defined in the O-RAN Subsystem Pair Interoperability Profile and in accordance to the O-RAN Deployment Blueprint. | +| 3. E2E System Testing | Testing for the Entire System defined in the O-RAN Deployment Blueprint
Testing is performed with the corresponding O-RAN System Profile, Test Cases, Performance Measurements and KPIs defined in the O-RAN System Profile and in accordance to the O-RAN Deployment Blueprint.

Additional iterations of E2E System Testing may be performed by replacing or updating a single Subsystem in the O-RAN System Profile. Such Subsystem Replacement iterations of E2E System Testing may include the same test conditions with a reduced set of test cases. | + +Figure 5-2: Stages and Sequence of Testing to be performed on the O-RAN Deployment Blueprint. The diagram shows a vertical flow of three testing stages, each with a corresponding description box. A large blue arrow on the left points upwards and is labeled 'Test Automation'. + +**Figure 5-2: Stages and Sequence of Testing to be performed on the O-RAN Deployment Blueprint** + +These various stages of testing can be performed (or repeated) for any modifications to the O-RAN Deployment Blueprint which can include one or more of the following conditions + +1. New Subsystem vendors +2. New releases of the software, firmware and/or hardware in any of the Subsystems +3. Configuration changes to the software, firmware and/or hardware in any of the Subsystems + +The modifications may or may not be accompanied with corresponding updates in the System profile, Subsystem Instance profiles, Subsystem Pair and Open Interfaces Interoperability profiles and therefore the test cases, performance measurements and KPIs. + +The modifications are required to be thoroughly reviewed to be able to evaluate the impacts of these modifications to the corresponding modified Subsystem Instance and the Subsystems Pair and E2E System associated with the modified Subsystem Instance. The impact evaluation can then be applied to the design and selection of test cases within each of the Test Stages needing to be executed due to the modifications. + +For example, a new release can be labelled as a major or minor release but it is only through detailed analysis of the modifications in this new release can help to determine the specific impacts and therefore test cases within each of the Test Stages needing to be executed for this new release. + +Subsystem Replacement Testing is an implementation variant of E2E System Testing with one of Subsystems replaced in the E2E System Test environment while keeping the other Subsystems and all the test configurations the same. Subsystem Replacement Testing methodology is further discussed in Section 5.4.1. + +Test Automation will be required to make the testing procedure extremely efficient as the Test Automation framework can be designed and used to handle repetitive, time-consuming tests which are required to be executed when any part of the Blueprint has been modified. This results in improved accuracy as automated tests perform the same steps precisely every time they are executed and create detailed reports. Test Automation is expected to be applied to all Stages of Testing shown in Figure 5-2. + +Figure 5-3 shows the scope and relationship of Subsystem Testing, Subsystem Pairing and Open Interfaces testing and E2E System Testing. + +O-RAN + + ALLIANCE + +O-RAN.TIFG.E2ETSTFWK.0-v01.00 + +![Figure 5-3: Scope and Relationship of Subsystem, Subsystem Pairing and Open Interfaces, E2E System Testing](f53ab3e2fe50b38ed8629ca5467d89b0_img.jpg) + +Detailed description of Figure 5-3: A block diagram showing the O-RAN architecture and test scopes. It includes components like SMO, Non-Real Time RIC, Near-Real Time RIC, O-Cloud, xApps, O-DU, O-RU, CU, and O-eNB. It highlights different test scopes: E2E System under Test, Subsystem under Test, Interface under Test, and Not in scope in this version of the specification. It shows interfaces like M-Plane, O1, A1, O2, E2, F1, X2, Xn, W1, and CUS-Plane/M-Plane (Hierarchical/Hybrid) connections. + +Figure 5-3: Scope and Relationship of Subsystem, Subsystem Pairing and Open Interfaces, E2E System Testing + +**Figure 5-3: Scope and Relationship of Subsystem, Subsystem Pairing and Open Interfaces, E2E System Testing** + +Few notes for clarification purposes on Figure 5-3 + +1. O-Cloud APIs and the Open APIs between the xApps and the Near-Real Time RIC can be Interfaces under Tests (IUTs) are not shown explicitly in Figure 5-3. +2. O-RU can be implemented as a NR O-RU, LTE O-RU or Dual mode NR and LTE O-RU. +3. OFH indicated includes WG4 CUS and M plane implementation and for M-Plane both Hierarchical and Hybrid models. Refer to [6][7] for more details. + +Figure 5-4 illustrates the concept of Subsystem Test, Subsystem Pair and Open Interface Test and System Testing using a multi-vendors setup example consisting of two O-RUs, one single O-DU and one single O-CU-CP/O-CU-UP. + +![Figure 5-4: Example of Subsystem, Subsystem Pair/ Open Interface and System Testing](5aace8e5ed93e3e25877049b1f39e821_img.jpg) + +Detailed description of Figure 5-4: A diagram illustrating three levels of testing: 1. Subsystem Test (testing individual DUTs from Vendor A, B, C, D), 2. Subsystem Pair & Interface Test (testing pairs of DUTs like O-RU and O-DU, or O-DU and O-CU-CP/UP connected via OFH or F1 interfaces), and 3. E2E System Test possible scenarios (testing the complete chain of O-RU, O-DU, and O-CU-CP/UP from different vendors). + +Figure 5-4: Example of Subsystem, Subsystem Pair/ Open Interface and System Testing + +**Figure 5-4: Example of Subsystem, Subsystem Pair/ Open Interface and System Testing** + +Noting that in this example, System Testing is performed for all the DUTs (used in this example) which have successfully completed Subsystem Testing, Subsystem Pair and Open Interfaces Interoperability Testing. The difference between System Testing and E2E System Testing is that the E2E System Testing is to be performed for all the Subsystems and Subsystem Pairs defined in an O-RAN Deployment Blueprint while System Testing can be performed for a subset of Subsystems and Subsystem Pairs defined in an O-RAN Deployment Blueprint. + +Copyright © 2020 by the O-RAN Alliance. + +Your use is subject to the terms of the O-RAN Adopter License Agreement in Annex ZZZ + +24 + +## 5.2 Subsystem Testing + +Subsystem Testing on each of the Subsystems defined in the O-RAN Deployment Blueprint is typically performed and passed before Interoperability Testing is to be performed for each of the Subsystem Pairs as defined in the Blueprint. + +Subsystem testing should be performed with the requirements of the Subsystem specified in the respective Subsystem Instance Profile and Test Cases and KPIs defined by the WGs responsible for the specification of the Subsystem. Noting that each Subsystem can have Requirements, Test Cases and KPIs specified by one or more WGs. + +Figure 5-5 shows a summarized view of the Subsystem, Subsystem Pair and Open Interfaces and the WGs responsible for the specification of each the Subsystem and Open Interfaces between the Subsystem Pairs. + +![Figure 5-5: Summarized view of the Subsystem, Subsystem Pair Open Interfaces and the responsible WGs. The diagram illustrates the O-RAN architecture components and their interconnections. Key components include SMO (WG1), Non-Real Time RIC (WG2), Near-Real Time RIC (WG3), O-Cloud (WG6), xApps, O-RU [NR] (WG4, WG7), FHM (Optional) (WG4), O-DU [NR] (WG4, WG5, WG6, WG7, WG8), O-CU-CP, O-CU-UP [NR] (WG1, WG3, WG6, WG7, WG8), O-RU [LTE] (WG4, WG7), FHM (Optional) (WG4), O-DU [LTE] (WG4), O-eNB (WG1, WG3, WG6, WG7), and CU [LTE]. Interfaces shown include M-Plane (Hybrid) (WG4) / O1 (WG1), O1 (WG1), A1 (WG2), O1 (WG1), O2 (WG6), OFH1 (WG4), OFH2 (WG4), F1 (WG5), X2, Xn (WG5), E2 (WG3), and W1. A legend on the right indicates: E2E System under Test (blue box), Subsystem under Test (green box), Interface under Test (blue box), and Not in scope in this version of the specification (white box). A note at the bottom right states: 1 CUS-Plane, 2 M-Plane (Hierarchical). A legend at the bottom left states: The circles at both ends of each line indicate the endpoints of each interface.](9c212a58170560c3e66df203432612b5_img.jpg) + +Figure 5-5: Summarized view of the Subsystem, Subsystem Pair Open Interfaces and the responsible WGs. The diagram illustrates the O-RAN architecture components and their interconnections. Key components include SMO (WG1), Non-Real Time RIC (WG2), Near-Real Time RIC (WG3), O-Cloud (WG6), xApps, O-RU [NR] (WG4, WG7), FHM (Optional) (WG4), O-DU [NR] (WG4, WG5, WG6, WG7, WG8), O-CU-CP, O-CU-UP [NR] (WG1, WG3, WG6, WG7, WG8), O-RU [LTE] (WG4, WG7), FHM (Optional) (WG4), O-DU [LTE] (WG4), O-eNB (WG1, WG3, WG6, WG7), and CU [LTE]. Interfaces shown include M-Plane (Hybrid) (WG4) / O1 (WG1), O1 (WG1), A1 (WG2), O1 (WG1), O2 (WG6), OFH1 (WG4), OFH2 (WG4), F1 (WG5), X2, Xn (WG5), E2 (WG3), and W1. A legend on the right indicates: E2E System under Test (blue box), Subsystem under Test (green box), Interface under Test (blue box), and Not in scope in this version of the specification (white box). A note at the bottom right states: 1 CUS-Plane, 2 M-Plane (Hierarchical). A legend at the bottom left states: The circles at both ends of each line indicate the endpoints of each interface. + +**Figure 5-5: Summarized view of the Subsystem, Subsystem Pair Open Interfaces and the responsible WGs** + +OFH indicated in Figure 5-5 includes WG4 CUS and M plane implementation and for M-Plane both Hierarchical and Hybrid models. Refer to [6][7] for more details. + +Table 5-1 shows the relationship between each of the Subsystem Types and the WGs responsible for various specifications aspects of these Subsystems. + +**Table 5-1: O-RAN Subsystems and WGs responsible for specifications** + +| Subsystem Type | Subsystem Implementation Option | WG and Specifications | +|----------------|-------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| O-RU | Separated/Integrated O-DU and O-RU Management Plane – Hierarchical and Hybrid modes | WG4: OFH CUS and M-plane specifications in cases where the O-DU and O-RU are implemented as separate nodes and they can either be co-located in the same or distributed locations | +| | Shared Cell (FHM or Cascade mode) | WG4: OFH specifications (CUS & M plane) | +| | Whitebox | WG7 | +| | Management Plane – Hybrid mode (WG4 M Plane Hybrid mode, O1 alignment) | WG4: M-Plane specification; WG1: O1 | +| | Location (Cell Site) | WG6: Cell Site (if VNF/CNF) (for further study FFS) | +| | Software and Hardware decoupling | WG6 (for further study FFS) | +| FHM | Shared Cell (FHM mode) | WG4: OFH specifications (CUSM plane) | +| O-DU | Management Plane | WG1: O1; WG5: O1; WG4: M-Plane specification (if the O-DU is not integrated with the O-RU) | + +| Subsystem Type | Subsystem Implementation Option | WG and Specifications | +|------------------------------------------|-----------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Separated/Integrated O-DU and O-RU | WG4: OFH CUS and M-plane specifications in cases where the O-DU and O-RU are implemented as separate nodes and they can either be co-located in the same or distributed locations | +| | Separated/Integrated O-DU and O-CU-CP/O-CU-UP | WG5: F1 C and U plane profiles where the O-DU and O-CU-CP/O-CU-UP are implemented as separate nodes and they can either be co-located in the same or distributed locations | +| | Software and Hardware decoupling | WG6 | +| | Reference Stack (PHY Hi, MAC/RLC) | WG8: O-DU Software Architecture and APIs specification | +| | Accelerator decoupling (AAL) | WG6 | +| | PNF, VNF, CNF | WG6: VNF, CNF | +| | Location (Cell, Edge site) | WG6: VNF/CNF | +| | Whitebox | WG7 | +| | Near-Real time RIC support (counters and stats perspective, E2) | WG3: E2; O-DU support for counters and stats perspective should be part of WG5 | +| Integrated O-CU-CP, O-CU-UP 1 | Base functions | WG1: Management Plane (O1)
WG5: O1 information and data models | +| | Separated/Integrated O-DU and O-CU-CP/O-CU-UP | WG5: F1 C and U plane profiles where the O-DU and O-CU-CP/O-CU-UP are implemented as separate nodes and they can either be co-located in the same or distributed locations | +| | Software and Hardware decoupling | WG6 | +| | Reference Stack (PDCP, RRC, SDAP – in SA mode) | WG8: O-CU-CP/O-CU-UP Software Architecture and APIs specification | +| | Accelerator decoupling (AAL) | WG6 | +| | PNF, VNF, CNF | WG6: VNF, CNF | +| | NR Deployment Options (NSA Option 3x, SA Option 2, others) | WG5: X2 (NSA), Xn (SA) | +| | Location (Edge, Regional site) | WG6: VNF/CNF | +| | Whitebox | WG7 | +| | Near-Real time RIC support (counters and stats perspective, E2) | WG3: E2; O-CU-CP/O-CU-UP support for counters and stats perspective should be part of WG5 | +| O-CU-CP | Base functions | WG5: F1-C; E1
WG1: Management Plane (O1)
WG5: O1 information and data models
Note: E1 not supported by existing WG5 specifications | +| | Software and Hardware decoupling | WG6 | +| | Reference Stack (PDCP, RRC) | WG8: O-CU-CP/O-CU-UP Software Architecture and APIs specification | +| | Accelerator decoupling (AAL) | WG6 | +| | PNF, VNF, CNF | WG6: VNF, CNF | +| | NR Deployment Options (NSA Option 3x, SA Option 2, others) | WG5: X2 (NSA), Xn (SA) | +| | Location (Edge, Regional site) | WG6: VNF/CNF | +| | Whitebox | WG7 | + +| Subsystem Type | Subsystem Implementation Option | WG and Specifications | +|--------------------|-------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Near-Real time RIC support (counters and stats perspective, E2) | WG3: E2; O-CU-CP/O-CU-UP support for counters and stats perspective should be part of WG5 | +| O-CU-UP | Base functions | WG5: F1-U; E1
WG1: Management Plane (O1)
WG5: O1 information and data models
Note: E1 not supported by existing WG5 specifications | +| | Software and Hardware decoupling | WG6 | +| | Reference Stack (PDCP, SDAP – in SA mode) | WG8: O-CU-CP/O-CU-UP Software Architecture and APIs specification | +| | Accelerator decoupling (AAL) | WG6 | +| | Management Plane (O1) | WG1: O1 | +| | PNF, VNF, CNF | WG6: VNF, CNF | +| | NR Deployment Options (NSA Option 3x, SA Option 2, others) | WG5: X2 (NSA), Xn (SA) | +| | Location (Edge, Regional site) | WG6: VNF/CNF | +| | Whitebox | WG7 | +| | Near-Real time RIC support (counters and stats perspective, E2) | WG3: E2; O-CU-CP/O-CU-UP support for counters and stats perspective should be part of WG5 | +| | | | +| O-eNB | Base functions | WG1: Management Plane (O1) | +| | Separated/Integrated O-DU and O-RU Management Plane – Hierarchical and Hybrid modes | WG4: OFH CUS and M-plane specifications in cases where the O-DU and O-RU are implemented as separate nodes and they can either be co-located in the same or distributed locations | +| | Software and Hardware decoupling | WG6 | +| | Accelerator decoupling (AAL) | WG6 | +| | PNF, VNF, CNF | WG6: VNF, CNF | +| | NR Deployment Options (NSA Option 3x) | WG5: X2 (NSA) | +| | Location (Cell, Edge, Regional site) | WG6: VNF, CNF | +| | Whitebox | WG7 | +| O-Cloud | Base functions | WG6: O2 | +| | Software and Hardware decoupling | WG6 | +| | Accelerator decoupling (AAL) | WG6 | +| | Location (Cell, Edge, Regional site) | WG6: VNF, CNF | +| Near-Real Time RIC | Base functions | WG3: E2, xApp; WG2: A1 | +| | PNF, VNF, CNF | WG6: VNF, CNF | +| | Location (Edge, Regional site) | WG6: VNF, CNF | +| | xApps | WG3 | +| Non-Real Time RIC | Base functions | WG2: A1 | +| | PNF, VNF, CNF | WG6: VNF, CNF | +| | Location (Edge, Regional site) | WG6: VNF, CNF | +| SMO | Base functions | WG1: O1, O2 | + +| Subsystem Type | Subsystem Implementation Option | WG and Specifications | +|----------------------------------------------------------------------------------------------|---------------------------------|-----------------------| +| xApp | Base functions | WG3 | +| 1 Refer to Table 4-2 for the mapping of Subsystem Type to O-RAN network functions | | | + +Performing Subsystem Testing on the O-DU for example will require Technical and Test specifications from + +1. WG1 and WG5 for O1 Management Plane support (WG1 specifies the management services provided over the O1 interface, WG5 specifies the information/data models referencing 3GPP specifications where required) +2. WG4 Open Fronthaul (OFH) CUS and M Planes (if the O-DU is not integrated with the O-RU) +3. WG5 Open F1 (if the O-DU is not integrated with the O-CU-CP and O-CU-UP) +4. WG6 Cloud Platform (if the O-DU is implemented as VNF/CNF running on a Cloud Platform) +5. WG8 Software Architecture and APIs (if the O-DU is implemented using multi-vendors Reference stacks) +6. WG6 Accelerator Abstraction Layer (AAL) (if the O-DU is implemented with Accelerator decoupling) +7. WG3 Near-Real time RIC support (if E2 is to be implemented) + +Performing Subsystem Testing on the O-RU for example will require Technical and Test specifications from + +1. WG4 Open Fronthaul (OFH) CUS and M Planes (if the O-RU is not integrated with the O-DU) +2. WG4 Open Fronthaul (OFH) CUS and M Planes (if the O-RU is configured in Shared Cell operation in either FHM or Cascade mode) +3. WG1 and WG4 for O1 Management Plane support (WG1 specifies the management services provided over the O1 interface, WG4 specifies the information/data models referencing 3GPP specifications where required. Noting that O1 support for O-RU is still work in progress) +4. WG7 Whitebox reference design (if the O-RU is implemented based on whitebox reference design) +5. WG4 Near-Real time RIC support (if performance counters and statistics are required to support use cases enabled through Near-Real time RIC) + +One of the key objectives of Subsystem testing is to validate the functionality of production grade DUT when the DUT is not operating in test mode and in few cases in standardized test mode as when required. One example of standardized test mode can be 3GPP test modes. + +Hence it is important to ensure that the DUT is not negatively impacted with the utilization of internal functions solely to support Subsystem testing, i.e., DUT is not expected to be testing tools when deployed in production networks and therefore DUT should not be used as testing tool during Subsystem tests. + +Subsystem tests are performed with a set of testing tools which are used to both apply active stimulus and as well as passive monitoring and measurements of the DUTs. + +It is recommended for Subsystem testing to adopt a wraparound testing approach for each of the Subsystem as the Device under Test (DUT) and Interfaces under Test (IUT), therefore providing a testing framework for comprehensive evaluation and testing prior to Multi-vendors Interoperability (MV-IOT) Subsystem pairing and Open interfaces testing. + +The wraparound testing approach involves emulating or using reference test platforms for the relevant Subsystems surrounding the Subsystem (DUT) as per defined in the O-RAN Deployment Blueprint. Reference test platforms can be Subsystems designed for commercial purpose or test applications which are used to support the wraparound test setup. For example, an O-Cloud reference test platform can be used to support wraparound testing of the virtualized/cloudified O-RAN network function designed to operate on the O-Cloud Subsystem. + +This would obviously include the required Service Management and Orchestration (SMO) and necessary procedures to bring the DUT into Operational state. + +Table 5-2 shows the relationship between each of the Subsystem Types and the surrounding Subsystems which are recommended to be emulated or using reference test platforms as part of the wrap around testing approach. + +**Table 5-2: Subsystem Types, Implementation Options and Surrounding Subsystems** + +| Subsystem Type | Subsystem Implementation Option | Surrounding Subsystems which are recommended to support wraparound testing | +|------------------------------------------|-----------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| O-RU | Separated/Integrated O-DU and O-RU | O-DU in cases where the O-DU and O-RU are implemented as separate nodes and they can either be co-located in the same or distributed locations | +| | Shared Cell (FHM) | FHM for CUS planes and NETCONF Client in O-DU/NMS for M plane | +| | Shared Cell (Cascade mode) | For O-RU #1..#N in the cascaded chain. O-DU in the case if O-RU #1 (DUT) is first in the chain closest to the O-DU; O-RU #N-1 in the case if O-RU #N (DUT) is last in the chain; For $N > 2$ and $X < N$ , O-RU #X-1 and O-RU #X+1 in the case if O-RU #X (DUT) | +| | Whitebox | Reference Hardware Platform | +| | Cloud Platform | Reference Cloud Platform (For further study FFS) | +| FHM | Shared Cell (FHM mode) | One or more O-RUs and One O-DU | +| O-DU | Management Plane | SMO (O1) | +| | Separated/Integrated O-DU and O-RU | One or more O-RUs in cases where the O-DU and O-RU are implemented as separate nodes and they can either be co-located in the same or distributed locations | +| | Separated/Integrated O-DU and O-CU-CP/O-CU-UP | O-CU-CP/O-CU-UP (F1-C/F1-U) in cases where the O-DU and O-CU-CP/O-CU-UP are implemented as separate nodes and they can either be co-located in the same or distributed locations | +| | Separated O-CU-CP and O-CU-UP | O-CU-CP (F1-C) and O-CU-UP (F1-U) | +| | Shared Cell (FHM) | FHM for CUS and M Plane. One or more O-RUs (NETCONF Server) for M-Plane | +| | Shared Cell (Cascade mode) | O-RU #1 | +| | Whitebox | Reference Hardware Platform | +| | Cloud Platform | Reference Cloud Platform | +| | Accelerator decoupling (AAL) | AAL | +| | Near-Real time RIC support | Near-Real time RIC (E2) | +| Integrated O-CU-CP, O-CU-UP 1 | Management Plane | SMO (O1) | +| | Separated/Integrated O-DU and O-CU-CP/O-CU-UP | One or more O-DUs (F1) in cases where the O-DU and O-CU-CP/O-CU-UP are implemented as separate nodes and they can either be co-located in the same or distributed locations | +| | Whitebox | Reference Hardware Platform | +| | Cloud Platform | Reference Cloud Platform | +| | Accelerator decoupling (AAL) | AAL | +| | NR Deployment Option (NSA Option 3x, 3a) | eNB (X2) | +| | NR Deployment Option (SA Option 2) | gNB (Xn) | +| | Near-Real time RIC support | Near-Real time RIC (E2) | +| O-CU-CP | Management Plane | SMO (O1) | +| | Separated O-CU-CP and O-CU-UP | One or more O-CU-UP (E1)
Note: E1 not supported by existing WG5 specifications | +| | Separated/Integrated O-DU and O-CU-CP | One or more O-DUs (F1-C) in cases where the O-DU and O-CU-CP are implemented as separate nodes and | + +| Subsystem Type | Subsystem Implementation Option | Surrounding Subsystems which are recommended to support wraparound testing | +|--------------------|------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | they can either be co-located in the same or distributed locations | +| | Whitebox | Reference Hardware Platform | +| | Cloud Platform | Reference Cloud Platform | +| | Accelerator decoupling (AAL) | AAL | +| | NR Deployment Option (NSA Option 3x, 3a) | eNB (X2) | +| | NR Deployment Option (SA Option 2) | gNB (Xn) | +| | Near-Real time RIC support | Near-Real time RIC (E2) | +| O-CU-UP | Management Plane | SMO (O1) | +| | Separated O-CU-CP and O-CU-UP | O-CU-CP (E1)
Note: E1 not supported by existing WG5 specifications | +| | Separated/Integrated O-DU and O-CU-UP | One or more O-DUs (F1-U) in cases where the O-DU and O-CU-UP are implemented as separate nodes and they can either be co-located in the same or distributed locations | +| | Whitebox | Reference Hardware Platform | +| | Cloud Platform | Reference Cloud Platform | +| | Accelerator decoupling (AAL) | AAL | +| | NR Deployment Option (NSA Option 3x) | eNB (X2) | +| | NR Deployment Option (SA Option 2) | gNB (Xn) | +| | Near-Real time RIC support | Near-Real time RIC (E2) | +| O-eNB | Management Plane | SMO (O1) | +| | Whitebox | Reference Hardware Platform | +| | Cloud Platform | Reference Cloud Platform | +| | NR Deployment Option (NSA Option 3x) | eNB (X2) | +| | Near-Real time RIC support | Near-Real time RIC (E2) | +| O-Cloud | Management Plane | SMO (O2) | +| | Cloud Platform | O-RAN network functions operating on Cloud platforms – O-DU, O-CU-CP, O-CU-UP, O-eNB, Near-Real time RIC, Non-Real time RIC, SMO | +| | Accelerator decoupling (AAL) | AAL | +| Near-Real Time RIC | Management Plane | SMO (O1) | +| | Cloud Platform | Reference Cloud Platform | +| | E2 Nodes | E2 Nodes (E2) – O-DU, O-CU-CP, O-CU-UP, O-eNB | +| | xApps | xApps | +| | Non-Real time RIC support | Non-Real time RIC (A1) | +| Non-Real Time RIC | Management Plane | SMO (O1) | +| | Cloud Platform | Reference Cloud Platform | +| | Near-Real time RIC support | Near-Real time RIC (A1) | +| SMO | Management Plane | O-RAN Managed Element (O1) | +| xApp | Near-Real time RIC support | Near-Real time RIC Platform and E2 Nodes (E2) - O-DU, O-CU-CP, O-CU-UP, O-eNB, Non-Real time RIC (A1) | + +Image: O-RAN Alliance Logo + +O-RAN.TIFG.E2ETSTFWK.0-v01.00 + +| Subsystem Type | Subsystem Implementation Option | Surrounding Subsystems which are recommended to support wraparound testing | +|----------------------------------------------------------------------------------------------|---------------------------------|----------------------------------------------------------------------------| +| 1 Refer to Table 4-2 for the mapping of Subsystem Type to O-RAN network functions | | | + +Performing Subsystem Testing using the wraparound test approach on the O-DU for example may require emulating or using reference test platforms for the following surrounding O-RAN network functions + +- One or more O-RUs (Open Fronthaul OFH) in cases where the O-DU and O-RUs are implemented as separate nodes +- O-CU-CP/O-CU-UP (F1-C/F1-U) in cases where the O-DU and O-CU-CP/O-CU-UP are implemented as separate nodes +- In Separated O-CU-CP and O-CU-UP configuration - O-CU-CP (F1-C) and O-CU-UP (F1-U) +- In Shared Cell (FHM) configuration - FHM for CUS and M Plane (Open Fronthaul OFH). One or more O-RUs (NETCONF Server) for M-Plane +- In Shared Cell (Cascade) configuration - O-RU #1 (Open Fronthaul OFH) +- Reference Cloud Platform +- Near-Real time RIC (E2) +- SMO (O1) + +Refer to the Subsystem Technical and Test specifications shown in Table 5-1 for more details on the recommended Subsystem Testing approach and detailed procedures. + +Figure 5-6 shows an example Wrap around testing setup with the O-DU configured in NR SA mode as the Subsystem under Test. + +![Figure 5-6: Wrap around testing setup for O-DU as the Subsystem under Test](d6027f3fec5389568b6bf8b485af78d3_img.jpg) + +Detailed Description of Figure 5-6: The diagram illustrates a wrap-around testing setup for an O-DU (Open Distributed Unit) configured in NR SA (New Radio Standalone) mode as the Subsystem Under Test (SUT). The setup includes various test equipment, emulated network functions, and interfaces. Key components include: + +- Test Equipment (Test or Emulated):** Includes UE (LTE-Uu, NR-Uu), Core Network (S1, NG), and Applications. +- Subsystem Under Test (SUT):** The O-DU [NR] is highlighted as the SUT. +- Emulated Network Functions / Reference Test Platforms:** Includes SMO (with Non-Real Time RIC), O-Cloud, Near-Real Time RIC (with xApps), O-RU, and FHM (Optional). +- Interfaces:** Various interfaces are shown connecting the components, such as O1, A1, E2, F1, OFH1, and OFH2. +- Not in Scope:** Components like O-RU (LTE), O-DU (LTE), and CU (LTE) are marked as not in scope for this test setup or version of the specification. + +Figure 5-6: Wrap around testing setup for O-DU as the Subsystem under Test + +**Figure 5-6: Wrap around testing setup for O-DU as the Subsystem under Test** + +OFH indicated in Figure 5-6 includes WG4 CUS and M plane implementation and for M-Plane both Hierarchical and Hybrid models. Refer to [6][7] for more details. + +## 5.3 Subsystem Pairing and Open Interfaces Interoperability Testing + +Subsystem Pairing and Open Interfaces Interoperability testing is typically performed after the Subsystem testing on each of the Subsystems involved in the Pairing has been successfully completed and prior to E2E System Testing on all the Subsystems and Subsystems Pairs defined in the O-RAN Deployment Blueprint. + +Copyright © 2020 by the O-RAN Alliance. + Your use is subject to the terms of the O-RAN Adopter License Agreement in Annex ZZZ + +31 + +Subsystem Pairing and Open Interfaces testing should be performed with the requirements of the Subsystem Pair and Open Interfaces specified in the respective Subsystem Pair Interoperability Profiles and Test Cases and KPIs defined by the WGs responsible for the specification of the Open Interfaces and Interoperability Test (IOT) profiles. + +Refer to the WGs' Technical and Test specifications for the respective Open Interfaces shown in Table 3-2 for more details on the recommended Subsystem Pairing and Open Interfaces testing approach and detailed procedures. + +One of the key objectives of Subsystem Pairing and Open Interfaces testing is to validate the functionality of production grade DUTs when all the DUTs are not operating in test modes. Hence it is important to ensure that the DUTs are not negatively impacted with the utilization of internal functions solely to support interoperability testing, i.e., DUTs are not expected to be testing tools when deployed in production networks and therefore DUTs should not be used as testing tools during interoperability tests. + +Interoperability tests are performed with a set of testing tools which are used to both apply active stimulus and as well as passive monitoring and measurements of the DUTs. + +It is recommended for Subsystem Pairing and Open Interfaces Interoperability testing to adopt a wraparound testing approach for each of the Subsystem Pair as the DUTs and Open Interface as the IUT, therefore providing a testing framework for comprehensive evaluation & testing prior to E2E System testing. + +The wraparound testing approach involves emulating or using reference test platforms for the relevant Subsystems surrounding the Subsystem Pair as the DUTs and Open Interface as the IUT as per defined in the O-RAN Deployment Blueprint. Reference test platforms can be Subsystems designed for commercial purpose or test applications which are used to support the wraparound test setup. For example, an O-Cloud reference test platform can be used to support wraparound testing of the virtualized/cloudified O-RAN network function designed to operate on the O-Cloud Subsystem. + +This would obviously include the required Service Management and Orchestration (SMO) and necessary procedures to bring the DUTs into Operational state. + +Table 5-3 shows the relationship between each of the Subsystem Pair and Open Interfaces and the surrounding Subsystems which are recommended to be emulated or using reference test platforms as part of the wrap around testing approach. + +**Table 5-3: O-RAN Subsystem Pair and Open Interfaces and the surrounding Subsystems** + +| O-RAN Open Interfaces | O-RAN Subsystem Pairs | Surrounding Subsystems which are recommended to support wraparound testing – if implemented (Interface) | +|-----------------------|----------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| A1 | Non-RT RIC function and Near-RT RIC function | E2 nodes (E2); SMO (O1)
O-Cloud reference platform (O-Cloud API) | +| E1 | O-CU-CP and O-CU-UP | O-DU (F1); near-RT-RIC function (E2); SMO (O1)
O-Cloud reference platform (O-Cloud API)
Note: E1 not supported by existing WG5 specifications | +| E2 | Near-RT RIC function and E2 Nodes for E2 functions | Non-RT-RIC function (A1); SMO (O1)
O-Cloud reference platform (O-Cloud API)
If E2 node is O-CU-CP/O-CU-UP: O-DU (F1-C/F1-U, E2)
If E2 node is O-DU: O-CU-CP/O-CU-UP (F1-C/F1-U, E2); O-RU (OFH); FHM (OFH)
If E2 node is O-eNB: no additional requirements | +| F1-C | O-CU-CP and O-DU | O-CU-UP (E1); O-RU (OFH); FHM (OFH); near-RT-RIC function (E2); SMO (O1)
O-Cloud reference platform (O-Cloud API)
Note: E1 not supported by existing WG5 specifications | +| F1-U | O-CU-UP and O-DU | O-CU-CP (E1); O-RU (OFH); FHM (OFH); near-RT-RIC function (E2); SMO (O1)
O-Cloud reference platform (O-Cloud API)
Note: E1 not supported by existing WG5 specifications | + +| O-RAN Open Interfaces | O-RAN Subsystem Pairs | Surrounding Subsystems which are recommended to support wraparound testing – if implemented (Interface) | +|----------------------------------------------------------------------|---------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------| +| O1 | O-RAN Managed Element and Management entity (SMO) | | +| O2 | SMO and O-Cloud | Management plane interface between SMO and O-Cloud | +| Open Fronthaul (OFH) CUS and M-Plane (Hierarchical and Hybrid Modes) | O-DU and O-RU | O-CU-CP (F1-CP); O-CU-UP (F1-UP); near-RT-RIC function (E2); SMO (O1)
O-Cloud reference platform (O-Cloud API) at the O-DU | +| Open Fronthaul (OFH) M-Plane (Hybrid Mode) | SMO and O-RU | O-DU (OFH) | +| X2-C | eNB and en-gNB | Near-Real Time RIC function (E2); SMO (O1)
O-Cloud reference platform (O-Cloud API) at the O-CU-CP/O-CU-UP and O-DU | +| X2-U | eNB and en-gNB | Near-Real Time RIC function (E2); SMO (O1)
O-Cloud reference platform (O-Cloud API) at the O-CU-CP/O-CU-UP and O-DU | +| Xn-C | eNB and ng-gNB | Near-Real Time RIC function (E2); SMO (O1)
O-Cloud reference platform (O-Cloud API) at the O-CU-CP/O-CU-UP and O-DU | +| Xn-U | eNB and ng-gNB | Near-Real Time RIC function (E2); SMO (O1)
O-Cloud reference platform (O-Cloud API) at the O-CU-CP/O-CU-UP and O-DU | + +1 + +2 Performing Subsystem Pairing and Open Interfaces Interoperability testing using the wraparound test approach on the O- +3 RU and O-DU for example may require emulating or using reference test platforms for the following surrounding O-RAN +4 network functions + +- 5 1. O-CU-CP (F1-C) and O-CU-UP (F1-U) in cases where the O-DU and O-CU-CP/O-CU-UP are implemented as +6 separate nodes +- 7 2. In Separated O-CU-CP and O-CU-UP configuration - O-CU-CP (F1-C) and O-CU-UP (F1-U) +- 8 3. Reference Cloud Platform in cases where the O-RU and/or O-DU is implemented on Cloud Platforms +- 9 4. Near-Real time RIC (E2) +- 10 5. SMO (O1) + +11 + +12 Noting that the OFH and the corresponding Management interfaces are the IUTs in this test setup. The rest of the interfaces +13 which are used to connect the DUTs to the emulated network functions and/or reference test platforms are not the IUTs +14 but required to support the wrap around testing approach. + +15 Refer to the Subsystem Technical and Test specifications shown in Table 3-2 for more details on the recommended +16 Subsystem Pairing and Open Interfaces Interoperability Testing approach and detailed procedures. + +17 Figure 5-7 shows an example with the O-RU and O-DU configured in NR SA mode, as the Subsystem under Test and +18 surrounding Subsystems which are recommended to be emulated or using reference test platforms for wrap around +19 Subsystem testing approach. + +O-RAN + +O-RAN.TIFG.E2ETSTFWK.0-v01.00 + +![Figure 5-7: Wrap around testing setup for O-RU and O-DU as the Subsystem Pair under Test](dd678240756573d5ab9e828fc6342326_img.jpg) + +Detailed description of Figure 5-7: The diagram illustrates a wrap-around testing setup. It shows various components including Test Equipment (UE, Core network, Applications), Subsystem under Test (O-RU [NR], O-DU [NR]), Interface under Test (OFH1, OFH2, F1, E2, O1, O2, A1), and Emulated network functions or Reference test platforms (SMO, Non-Real Time RIC, Near-Real Time RIC, O-Cloud, O-CU-CP, O-CU-UP [NR], O-eNB, O-RU [LTE], FHM, O-DU [LTE], CU [LTE]). The diagram maps out the connections and interfaces between these components, indicating which are in scope for this test setup and which are not. + +Figure 5-7: Wrap around testing setup for O-RU and O-DU as the Subsystem Pair under Test + +Figure 5-7: Wrap around testing setup for O-RU and O-DU as the Subsystem Pair under Test + +OFH indicated in Figure 5-7 includes WG4 CUS and M plane implementation and for M-Plane both Hierarchical and Hybrid models. Refer to [6][7] for more details. + +## 5.4 E2E System Multi-vendors Interoperability Testing + +Multi-vendors interoperability (MV-IOT) system testing enables validation and verification of the entire O-RAN Deployment Blueprint as a complete E2E system under test (SUT). + +E2E System testing should be performed after Subsystem Testing, Subsystem Pair and Open Interfaces Interoperability Testing have been successfully completed for all the Subsystems and Subsystem Pairs defined in an O-RAN Deployment Blueprint. + +One of the key objectives of E2E System testing is to validate the functionality of production grade DUTs when all the DUTs in the SUT are not operating in test modes. Hence it is important to ensure that the DUTs are not negatively impacted with the utilization of internal functions solely to support interoperability testing, i.e., DUTs are not expected to be testing tools when deployed in production networks and therefore DUTs should not be used as testing tools during E2E System tests. + +E2E System tests are performed with a set of testing tools which are used to both apply active stimulus and as well as passive monitoring and measurements of the DUTs. + +It is recommended for System testing to adopt a wraparound testing approach for all the Blueprint defined Subsystems as DUTs and Open interface connecting these Subsystems as IUTs, therefore providing a testing framework for comprehensive evaluation and testing. + +The wraparound testing approach involves using Test Equipment such as the UEs (test and/or emulated), Applications/Services (test and/or emulated) and Core network (test and/or emulated) as shown in Figure 5-8 below. + +Copyright © 2020 by the O-RAN Alliance. + Your use is subject to the terms of the O-RAN Adopter License Agreement in Annex ZZZ + +34 + +![Figure 5-8: Wrap around testing setup for E2E System under Test (SUT). The diagram illustrates a testing environment where Test Equipment (Test or Emulated) interacts with the E2E System under Test. The Test Equipment includes a UE (User Equipment) and Applications/Core network. The E2E System under Test is composed of several layers: SMO (Service Based Interface), Non-Real Time RIC, O-Cloud, Near-Real Time RIC, O-DU [NR], O-CU-CP, O-CU-UP [NR], O-DU [LTE], and CU [LTE]. The system is connected to Transport as a Service (xHaul). The diagram also shows various interfaces like O1, A1, E2, F1, X2, Xn, and W1. A legend on the right indicates that the E2E System under Test, Subsystem under Test, and Interface under Test are within the scope, while the Core network and CU [LTE] are not in scope in this version of the specification.](554e038618f507726cc8b241ae1cec25_img.jpg) + +The circles at both ends of each line indicates the endpoints of each interface + +Figure 5-8: Wrap around testing setup for E2E System under Test (SUT). The diagram illustrates a testing environment where Test Equipment (Test or Emulated) interacts with the E2E System under Test. The Test Equipment includes a UE (User Equipment) and Applications/Core network. The E2E System under Test is composed of several layers: SMO (Service Based Interface), Non-Real Time RIC, O-Cloud, Near-Real Time RIC, O-DU [NR], O-CU-CP, O-CU-UP [NR], O-DU [LTE], and CU [LTE]. The system is connected to Transport as a Service (xHaul). The diagram also shows various interfaces like O1, A1, E2, F1, X2, Xn, and W1. A legend on the right indicates that the E2E System under Test, Subsystem under Test, and Interface under Test are within the scope, while the Core network and CU [LTE] are not in scope in this version of the specification. + +**Figure 5-8: Wrap around testing setup for E2E System under Test (SUT)** + +OFH indicated in Figure 5-8 includes WG4 CUS and M plane implementation and for M-Plane both Hierarchical and Hybrid models. Refer to [6][7] for more details. + +E2E System Testing should be performed with the test configuration from the following listed profiles + +1. Subsystem Profiles for all the Subsystems (e.g. xApp supporting Dynamic Traffic Steering) +2. Subsystem Pair IOT Profile for all the Subsystem Instance Pairs (e.g. OFH between the O-DU and O-RU) +3. System Profile for the entire O-RAN Deployment Blueprint + +Recommendations and considerations for E2E System Testing test cases and KPIs are further detailed in Chapter 6. + +### 5.4.1 Subsystem Replacement Testing + +One variant of the E2E System Testing which can be considered is the Subsystem Replacement Testing approach when the E2E System Testing is performed. + +Subsystem Replacement Testing approach involves replacing one of Subsystems in the E2E System Test environment with the other Subsystems and all the test configurations remaining the same. + +The Subsystem Replacement Testing approach can be useful for testing the following scenarios within the E2E System Testing environment as it is important to evaluate the compatibility and impact of such changes of the Subsystem to the entire E2E System specified per the O-RAN Deployment Blueprint + +1. Testing multiple vendors offering the same Subsystem (instance) +2. Testing upgrades (software/firmware/hardware) to a Subsystem (instance) +3. Testing major parameters changes to a Subsystem (instance) which have been either determined or needing to be evaluated for potential System-wide impacts (e.g. expiry value of a certain timer which may have cascaded impact through the E2E system as per defined in the O-RAN Deployment Blueprint) + +Subsystem Replacement Testing can be applied when a reduced scope of testing and set of test cases can be performed depending on the Subsystem replaced for any of the above listed scenarios. Scope reduction for the testing and test cases are typically determined through detailed impact analysis of the Subsystem (to be replaced) and scenarios. + +In this case, prior to performing E2E System Testing (described in section 5.4), the Subsystem (to be replaced) must successfully complete both Subsystem Testing (described in section 5.2) and Subsystem Pair and Open Interfaces Interoperability Testing (described in section 5.3) based on the determined scope of testing and set of test cases. + +Figure 5-9 shows the wrap around testing setup for E2E System under Test with one of the Subsystems replaced. In this example, the O-DU subsystem is replaced as part of the E2E System Testing setup. Multiple vendors' O-DUs can be tested in the same E2E System Testing environment with the other Subsystems in the E2E test environment remaining the same. + +![Figure 5-9: Wrap around testing setup for E2E System under Test (SUT) with one Subsystem Replaced. The diagram illustrates a testing environment where the O-DU subsystem is replaced. It shows the Test Equipment (Test or Emulated) containing a UE (LTE-Uu, NR-Uu) and Applications/Core network (S1, NG). The E2E System under Test includes SMO, Non-Real Time RIC, O-Cloud, Near-Real Time RIC, xApps, O-DU [NR], O-CU-CP, O-CU-UP [NR], O-RU [NR], FHM (Optional), O-RU [LTE], O-DU [LTE], and CU [LTE]. The Subsystem Replaced is O-DU [NR]. The diagram also shows the Transport as a Service (xHaul) and the O-eNB. A legend indicates the color coding for Test Equipment, E2E System under Test, Subsystem under Test, Interface under Test, Subsystem Replaced, and Not in scope in this version of the specification. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'.](03dcfa5ba917d3e7a6b90a625c7f4c22_img.jpg) + +Figure 5-9: Wrap around testing setup for E2E System under Test (SUT) with one Subsystem Replaced. The diagram illustrates a testing environment where the O-DU subsystem is replaced. It shows the Test Equipment (Test or Emulated) containing a UE (LTE-Uu, NR-Uu) and Applications/Core network (S1, NG). The E2E System under Test includes SMO, Non-Real Time RIC, O-Cloud, Near-Real Time RIC, xApps, O-DU [NR], O-CU-CP, O-CU-UP [NR], O-RU [NR], FHM (Optional), O-RU [LTE], O-DU [LTE], and CU [LTE]. The Subsystem Replaced is O-DU [NR]. The diagram also shows the Transport as a Service (xHaul) and the O-eNB. A legend indicates the color coding for Test Equipment, E2E System under Test, Subsystem under Test, Interface under Test, Subsystem Replaced, and Not in scope in this version of the specification. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +**Figure 5-9: Wrap around testing setup for E2E System under Test (SUT) with one Subsystem Replaced** + +OFH indicated in Figure 5-9 includes WG4 CUS and M plane implementation and for M-Plane both Hierarchical and Hybrid models. Refer to [6][7] for more details. + +# Chapter 6 O-RAN E2E Test Cases and KPIs + +## 6.1 Introduction + +The O-RAN E2E testing framework aims to evaluate the entire O-RAN Deployment Blueprint holistically as a System under Test (SUT) based on a set of well-defined E2E Test Cases and Key Performance Indicators (KPIs). + +The purpose of this Chapter is to outline the key considerations along with information to help guide testing and validating the O-RAN Deployment Blueprints with the relevant E2E Test Cases and KPIs. + +The following considerations will be discussed in further details in the next sections in this Chapter + +1. Use Cases and Services Requirements +2. O-RAN Deployment Blueprint dependencies +3. Relevance of 3GPP KPIs +4. Relevance of NGMN 5G Test Cases and KPIs defined in [10] +5. Test Conditions to be considered +6. Test Scenarios and KPIs to be considered + +## 6.2 Use Cases and Services Requirements + +The selection of the E2E Test Cases and KPIs are determined mainly by 2 factors + +1. Use Cases and Services +2. O-RAN Deployment Blueprint which are optimized according to the Use Cases and Services requirements + +Figure 6-1 shows a few examples for each of the major categories of use cases and services which are supported by 3GPP and O-RAN compliant networks. + +![](6af530a1c7409881ba24e524bea43416_img.jpg) + +| Use Cases and Services | | | +|-------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3GPP Services
  • • Voice Services - e.g. EPS Fallback, VoNR
  • • Others
| Operators Services
  • • Fixed Wireless
  • • eMBB
  • • RAN Sharing
  • • Others
| O-RAN specified Use Cases
  1. 1. QoE Optimization
  2. 2. Traffic Steering
  3. 3. Massive MIMO Beamforming Optimization
  4. 4. RAN Sharing
  5. 5. QoS based Resource Optimization
  6. 6. RAN Slice SLA Assurance
  7. 7. Context based Dynamic HO Management for V2X
  8. 8. Flight Path based Dynamic UAV Radio Resource Allocation
  9. 9. Radio Resource Allocation for UAV Application Scenario
| +| Reference: O-RAN Use Cases and Deployment Scenarios WhitePaper | | | + +**Figure 6-1: Examples of Use Cases/Services supported by 3GPP compliant and O-RAN RIC-enabled networks** + +To convince an operator to invest in O-RAN infrastructure, 3GPP and Operators' Services which can be supported with 3GPP compliant networks must be well supported with O-RAN compliant networks. + +It can therefore be expected that operators will require comprehensive system testing and evaluation to be performed on the O-RAN Deployment Blueprints using the E2E Test Cases and KPIs which are defined for the 3GPP and Operators' Services that are of interest to them. + +O-RAN Alliance has specified a set of prioritized use cases which can be only supported by O-RAN RIC-enabled networks. These use cases leverage the O-RAN architecture and demonstrates its unique benefits. Key benefits of O-RAN architecture include the ability to utilize machine learning systems and artificial intelligence back end modules to empower network intelligence through open and standardized interfaces / feeds in a multi-vendor network. + +Operators will require guidance on the E2E Test Cases and KPIs which can be used to test and evaluate the performance for each of these RIC-enabled use cases in order to be able to quantify the benefits of implementing these use cases using O-RAN RIC-enabled networks as compared to networks without O-RAN RIC capabilities. + +## 6.3 O-RAN Deployment Blueprint dependencies + +An O-RAN Deployment Blueprint can consist of multiple Subsystems from possibly multiple vendors. The KPIs can be measured as E2E KPIs across any combinations of vendors and as well as Subsystems and Subsystems Pairs KPIs for the different Subsystems and the Open interfaces between the Subsystems respectively. + +The specific Performance Measurements, KPIs and their respective values defined for Subsystem Testing, Subsystem Pair and Open Interfaces Testing and E2E System Testing will be dependent on the O-RAN Deployment Blueprints. + +For example, from the E2E System Testing perspective, the beam forming system performance gain KPIs specified for outdoors macro cells would not be applicable for indoors small cells which may not require beam forming capabilities. Similarly, the beam forming performance gain measurements specified for the O-RUs which are designed and optimized for outdoors macro cells systems would not be applicable for O-RUs which are designed and optimized for indoors small cells. + +It is therefore important to ensure that testing is performed for each of the + +1. Subsystem Instances with their defined Subsystem Instance profiles and associated KPIs +2. Subsystem Instances pairs with their defined Subsystem Pairs Interoperability profiles and associated KPIs +3. System Deployment Blueprints with the defined E2E System KPIs + +## 6.4 Relevance of the 3GPP KPIs + +As highlighted in Section 6.2, operators will require validation of the O-RAN Deployment Blueprints that the overall 3GPP System characteristics is as expected. + +In general, 3GPP defines two categories of RAN KPIs + +1. Performance data for technology tests, trials, and evaluation such as in 3GPP TR 38.913. +2. Performance data for network monitoring, assessment, analysis, optimization, and assurance which will be further discussed in Section 6.4.1. + +The same set of E2E KPI categories and KPIs which are defined for 3GPP compliant networks and services will be directly applicable for O-RAN compliant networks. + +Additional considerations for the application of 3GPP defined KPIs for O-RAN Deployment Blueprint testing and verification will be discussed in Section 6.4.2. + +### 6.4.1 3GPP KPIs defined for network monitoring, assessment, analysis, optimization and assurance + +From the 3GPP system perspective, the E2E KPIs defined for network monitoring, optimization and assurance are typically defined for the following categories + +1. Availability (e.g. cells ready to service connections) +2. Accessibility (e.g. connection establishment rates, attempts/failures, latency) +3. Integrity (e.g. throughput, latency, jitter, retransmission rates) +4. Mobility (e.g. intra/inter RATs handover rates, interruption times for control / user planes) +5. Reliability (e.g. amount of sent packets which are successfully delivered to the destination within the time constraint required by the target service, divided by the total number of sent packets) +6. Retainability (e.g. drop rates for PDN/PDU sessions, call session) +7. Utilization (e.g. resources utilization based on certain traffic conditions and profiles such as fronthaul, compute) +8. Energy Efficiency (e.g. power consumption based on certain traffic conditions and profiles) + +3GPP TS 28.554 [9] has defined a set of E2E KPI for the 5G System (5GS) and network slicing including the NR RAN and 5G Core (5GC). + +### 6.4.2 Applicability to RAN, RAN Slices, Users and Services + +3GPP KPIs are typically defined for 3GPP networks (RAN and Core), E2E network slices and 3GPP hosted services such as 3GPP voice services with VoLTE, EPS Fallback, VoNR and others. + +Additional important KPIs dimensions which are required to be considered for O-RAN Deployment Blueprint testing and verification include + +1. RAN Slices even though 3GPP has not yet standardized RAN slicing, this is one of the O-RAN use cases +2. Users and Services QoS to be evaluated for Accessibility, Integrity, Mobility, Retainability +3. Users and Services QoE to be evaluated + +## 6.5 Relevance of the NGMN 5G Test Cases and KPIs + +NGMN has developed a set of E2E Test Cases and KPIs which are designed to evaluate the performance of 3GPP 5G NR networks [10] with its work on the definition of the testing framework for NGMN's Pre-Commercial 5G networks trials initiative. + +The current published version of this NGMN document focuses on outdoors field testing of the 5G NR system configured in NSA EN-DC mode, which includes validation of the 5G NR radio interface, E2E KPIs and features which require E2E validation such as the E2E latency and E2E network slicing. + +This set of NGMN defined E2E Test Cases and KPIs can be leveraged to a large extent for testing and validating the O-RAN Deployment Blueprints in both the lab and field-testing environments. + +Table 6-1 lists the E2E Test Cases and KPIs documented in [10] which should be referred to for more details. + +**Table 6-1: NGMN Pre-Commercial 5G networks trials E2E Test Cases and KPIs [10]** + +| Test Case focus | KPIs and Test Scenarios | +|--------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Trial test requirements | | +| Latency | Control Plane and User Plane Latency | +| User Throughput | Peak throughput
Throughput at interference limited Cell edge
Cell edge coverage throughput
Throughput in different coverage conditions (link budget test)
Throughput in different interference conditions (Average User Throughput) | +| Cell capacity | Cell peak throughput
Cell average throughput | +| Spectral efficiency | User and Cell Spectral efficiency | +| Coverage | Outdoor Single-cell Coverage
Outdoor Multi-Cell Continuous Coverage
Outdoor to Indoor Coverage
Indoor Coverage | +| Mobility | Intra-Cell mobility testing
Inter-Cell Mobility (Handover) Testing | +| Reliability | Success probability of transmitting a set number of bytes within a certain delay | + +| Test Case focus | KPIs and Test Scenarios | +|----------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Retainability | Capability of the network to retain a service by a UE for a desired duration once the user is connected to the service - Call drop rate, Call setup complete rate, Dual connectivity drop rate | +| User experience | Examples Content Distribution Streaming Service QoE, Social Networking QoE, High Speed Internet QoE | +| Energy efficiency | UE energy efficiency
Network energy efficiency | +| Inter-RAT procedures | NSA Inter-RAT Mobility with PS Service
SA Inter-RAT Mobility with PS Service | +| RAN architecture split | CU-DU Separation
CP-UP Separation | +| Service or technology specific requirements | | +| Location/Positioning service | EPS Scenario (Option 3), 5GS Scenario (NG-RAN) | +| Fixed wireless access | Average and peak throughput | +| | Meeting throughput speed tier guarantees | +| | End-to-end latency performance | +| | Beam tracking range (horizontal/azimuthal) for base station and CPE/UE antennas | +| | Quality of Service differentiation scenarios for Voice/video application | +| | Number of (active) users served per base station | +| Voice Services | Geographic coverage area | +| | Robustness to environmental blockage (mmWave) | +| | EPS Fall-back, Voice Over NR | + +1 + +## 6.6 Test Conditions to be considered + +As highlighted in the earlier sections, the E2E System Test Cases and KPIs which are defined by 3GPP will be directly applicable for testing and validating the O-RAN Deployment Blueprints, while those defined by NGMN in [10] can be leveraged to a large extent for similar purpose. + +However, it is important to take into considerations the following aspects when testing and validating O-RAN Deployment Blueprints + +1. Multi-vendors interoperability +2. Functional, Performance including normal and abnormal conditions +3. Radio channel variations and impacts on the overall system performance and Quality of Experience (QoE) +4. Management, Orchestration and Network Automation +5. Additional considerations related to practical deployment aspects + +13 + +### 6.6.1 Multi-vendors interoperability + +As the O-RAN Deployment Blueprint can consist of multiple Subsystems from possibly multiple vendors, additional considerations for O-RAN focused system test scenarios, conditions and KPIs will be required to validate and evaluate the performance of multi-vendors interoperability in accordance to the O-RAN Deployment Blueprint definition. + +For example if the O-RUs, O-DUs and O-CU-CPs/O-CU-UPs in an O-RAN Deployment Blueprint are provided by different vendors, then it would be important to ensure that the E2E KPIs are evaluated with the appropriate E2E test + +19 + +cases and test scenarios which can be used to validate multi-vendors interoperability between these O-RAN network functions. + +### 6.6.2 Functional, Performance including normal and abnormal conditions + +Multi-vendors interoperability testing typically includes functional validation for handling normal conditions. + +However, similar to how the 3GPP Radio Access Networks are expected to be tested and optimized for Performance and Abnormal conditions handling, operators would be expecting the O-RAN Deployment Blueprints to be tested and optimized in the same manner. + +O-RAN Deployment Blueprints consisting of Subsystems from multiple vendors will therefore require Multi-vendors interoperability testing to include testing for Performance and Abnormal conditions handling. + +Performance testing can be used to evaluate how well each individual Subsystem, each pair of Subsystem Instances and all the Subsystems in the O-RAN Deployment Blueprint inter-operate to achieve the best in class cost-performance ratio. + +This can include quantifying the O-RAN Deployment Blueprint when Subsystems from multiple vendors inter-operate under Performance test conditions through + +1. Performing testing using the same set of KPIs, for example examining if the latency figures can be achieved in performance testing conditions. +2. Measuring resources utilization efficiency for example with Radio resource blocks, Open Fronthaul and xHaul transport, O-Cloud computing / networking / storage and power consumption / energy efficiency. + +Abnormal testing will in some cases be required to be performed to validate fault management and zero-touch network automation techniques such as self-healing functions. + +### 6.6.3 Radio channel variations and impacts on the overall system performance and QoE + +Radio access networks should be tested with close to real-world radio channel conditions, variations of the channel conditions and mobility patterns in the lab environment for a proper evaluation of the overall system performance of the RAN and QoE of the services handled by the RAN. + +For example testing key 3GPP RAN functions such as Radio resource, Beam / Cell level mobility management and advanced use cases defined by O-RAN such as Traffic Steering and Massive MIMO Beamforming Optimization will require the test environment to be setup with the appropriate network and slices topology, radio channel conditions, UEs distributions and mobility patterns, which otherwise these functions and use cases cannot be properly tested and evaluated. + +Testing O-RAN Deployment Blueprints consisting of Subsystems from multiple vendors under the appropriate radio channel conditions and mobility patterns will be required to validate how well the multi-vendors Subsystems inter-operate under these test conditions. + +### 6.6.4 Management, Orchestration and Network Automation + +In general, operators require the Management & Orchestration (MANO) and Network Automation capabilities of their networks to be robustly validated. + +In order for operators to be able to deploy O-RAN networks and network slices which can consist of Subsystems from multiple vendors, multi-vendors interoperability testing will be required for validating the management and orchestration functions of all the Subsystems defined in the O-RAN Deployment Blueprints. + +O-RAN Alliance has specified a set of prioritized use cases for O-RAN orchestration of virtualized RAN and the interfaces used for management and orchestration, in particular the O1 interface between the service management and orchestration framework and the RAN managed functions and the O2 interface between the service management and orchestration framework and the O-Cloud Infrastructure Management Services/Deployment Management Services that controls resource assignment for Virtualized Network Functions. + +Operators will require guidance on the E2E Test Cases and KPIs which can be used to test and evaluate the functionality and performance for each of these orchestration use cases in order to be able to quantify the feasibility and benefits of deploying O-RAN compliant networks. + +### 6.6.5 Additional considerations related to practical deployment aspects + +In addition to performing testing based on 3GPP, ITU-T, IEEE specified functionalities, it is important as well to take into considerations the practical deployment aspects which operators will need to consider and therefore tested as part of the E2E Testing framework. These considerations include + +1. Performance Evaluation and Monitoring +2. Robustness, Resilience, Reliability, Security +3. Troubleshooting and Root Cause Analysis (RCA) +4. Practical Network Operating Conditions such as fronthaul transport loading and non-zero variable delays +5. FCAPS including fault, configuration, accounting, performance, and security management +6. System Deployment lifecycle (installs, upgrades) +7. Virtualization, interaction with O-Cloud (NFVi), Management and Orchestration (MANO) +8. Evolution towards Zero Touch Automation network management + +System Deployment lifecycle (installs, upgrades) involves multiple phases of the System Deployment lifecycle which will include new installs and as well as future field upgrades scenarios such as + +1. Performing software or firmware upgrades of the existing installed O-RAN Network Functions (e.g. increased performance, enhanced capabilities such as dynamic spectrum sharing, bug fixes and others) +2. Installing new O-RAN Network Functions which are required to interoperate with existing installed O-RAN Network Functions (e.g. adding new O-RUs from a new vendor to the field operational O-DU currently serving O-RUs from the current vendor, new xApp to be installed onto the current near-RT RIC) +3. Installing new or Replacing existing hardware (or O-Cloud) to support existing installed O-RAN Network Functions (e.g. adding, replacing storage, networking, computing resources) + +It is therefore important to define testing templates ensuring that the essential testing is performed for the specific Subsystem Instances, Subsystem Instances Pairs and Open Interfaces and System Deployment Blueprint which are affected by the System Deployment lifecycle scenarios. + +## 6.7 Test Scenarios and KPIs to be considered + +A few examples of Test Scenarios and KPIs which are needing to be considered for testing O-RAN Deployment Blueprint consisting of Subsystems from multiple vendors are shared in more details in this section. + +1. Mobility management +2. Deployability + +### 6.7.1 Mobility Management + +Mobility management test cases may need to consider test scenarios which involve testing multi-vendors interoperability between Subsystems provided from multiple vendors. + +Test scenarios can include intra O-RU (inter beams for intra cell and inter cells), inter O-RUs (intra O-DU), inter O-DUs (intra O-CU-CP/O-CU-UP), inter O-CU-CP/O-CU-UPs, Intra vs Inter RATs handovers in Idle and Connected modes. + +Figure 6-2 shows an example of a test scenario which can be used to verify the interoperability aspects of mobility management in a multi-vendors O-RAN Deployment Blueprint test setup. + +![Figure 6-2: Test Scenario for verifying multi-vendors interoperability aspect of Mobility Management. The diagram shows a network architecture with a Near-Real Time RIC (Vendor Near-RT RIC 1) at the top, connected via E2 interfaces to O-CU-CP/UP (Vendor C1) and O-CU-CP/UP (Vendor C2). These are connected via F1 interfaces to O-DU (Vendor D1, D2, D3) and O-RU (Vendor R1, R2, R3, R4). A Mobility Path arrow indicates the UE's movement from R1 to R2, R3, and R4. A table on the right details the sequence of events.](ba65434ddc0b64ba1ac9b29466731449_img.jpg) + +| Seq. | O-CU-CP/UP | O-DU | O-RU | Scenario | +|------|------------|------|------|---------------------------------| +| 1 | C1 | D1 | R1 | Initial State
OFH, F1 | +| 2 | C1 | D1 | R2 | Intra O-DU
OFH | +| 3 | C1 | D2 | R3 | Inter O-DU
OFH, F1 | +| 4 | C2 | D3 | R4 | Inter O-CU-CP/UP
OFH, F1, Xn | + +Figure 6-2: Test Scenario for verifying multi-vendors interoperability aspect of Mobility Management. The diagram shows a network architecture with a Near-Real Time RIC (Vendor Near-RT RIC 1) at the top, connected via E2 interfaces to O-CU-CP/UP (Vendor C1) and O-CU-CP/UP (Vendor C2). These are connected via F1 interfaces to O-DU (Vendor D1, D2, D3) and O-RU (Vendor R1, R2, R3, R4). A Mobility Path arrow indicates the UE's movement from R1 to R2, R3, and R4. A table on the right details the sequence of events. + +**Figure 6-2: Test Scenario for verifying multi-vendors interoperability aspect of Mobility Management** + +In this test scenario + +1. UE is first connected through O-RU (R1), O-DU (D1), O-CU-CP/UP (C1) +2. UE then moves towards O-RU (R2) which is an inter O-RU and intra O-DU mobility scenario +3. UE then moves towards O-RU (R3) which is an inter O-RU and inter O-DU mobility scenario +4. UE then moves towards O-RU (R4) which is an inter O-RU, inter O-DU and O-CU-CP/UP mobility scenario + +The Mobility KPIs including handover attempts/success rates, interruption time (aka latency) to control, user plane and services plane, services performances such as packet losses, jitter and latency should be measured in order to validate that the services SLAs can be met while executing the test sequences. + +### 6.7.2 Deployability + +One of the key considerations for dis-aggregated RAN deployments is the requirements for the underlying transport network which will be dependent on the requirements of the Services and dis-aggregated RAN functions which will be required to interwork over the transport network segments. + +These requirements are typically simulated, estimated, tested, measured, and validated for dis-aggregated RAN transport planning purposes. + +O-RAN Deployment Blueprints will be required to go through similar process with the additional complexity that the Subsystems in the same O-RAN Deployment Blueprint may be provided by different vendors which may have different levels of influences on the transport requirements therefore needing to be tested and validated with test setup considerations outlined in Section 6.6. + +The Integrity and Utilization KPIs including transport capacity/throughput, packet losses, jitter and latency should be measured during the testing process taking into considerations the following aspects + +1. Capacity/throughput for Open fronthaul interface for transport planning purposes, which can vary depending on test scenarios and key factors such as radio conditions among others outlined in Section 6.6.3. +2. Latency for transport planning purposes and delay management interoperability which can vary dependent on the transport options and can be impacting performance and users-services experiences. +3. Resources Utilization based on test profiles which should include networking, computing, storage resources. + +# Annex A: Operators' inputs on Deployment Blueprints + +Annex A lists the O-RAN Deployment Blueprint profiles which have been submitted by global operators to O-RAN Alliance to assist with developing comprehensive E2E testing methodologies and test cases taking into considerations these submitted profiles. + +## A.1 Operator #1 inputs + +### NR Deployment Options and Evolution + +1. Step1: (NSA EN-DC) Option 3x (based on X2 interface and EPC) +2. Step2: Step1 + (SA 5G) Option 2 +3. Step3: Step2 + (ng-LTE) Option 5/Option 7x (based on Xn interface and 5GC) + +#### Use Cases focuses + +1. RAN Sharing +2. Near-RT RIC (edge-cloud) Non-RT-RIC Use Cases (regional-cloud): Traffic Steering, QoE/QoS, Massive MIMO Beam Forming and Optimization + +E2E Performance requirements of Application / Network Slices – references to NGMN Definition of the Testing Framework for the NGNM 5G Pre-Commercial Network Trials [10]. + +**Table A-1: Operator #1 inputs - System Profile considerations** + +| System Profiles considerations | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|----------------------------------|----------------------------------------------------------------------|----------------------------------------------------------------------|------------------------------------|--------------------------------------|--------------------------------------| +| Service Priority | eMBB (NR and LTE) | eMBB (NR and LTE) | eMBB (LTE) | eMBB (NR), URLLC (NR) | eMBB (NR), URLLC (NR) | +| Deployment Scenarios | Outdoor Macro/Micro Cell and RAN Sharing | | | | | +| Deployment Options and Evolution | NSA EN-DC Option 3x with X2 between eNB and en-gNB; and EPC | NSA Option 7x with Xn between gNB and ng-eNB; and 5GC | (ng-LTE) SAS Option 5 with 5GC | NR Standalone (SA) Option 2 with 5GC | NR Standalone (SA) Option 2 with 5GC | +| NR Spectrum Bands | NR: FR1 - 3.7 GHz TDD, 700 MHz FDD
LTE: 2.6GHz/1800MHz/800MHz FDD | NR: FR1 - 3.7 GHz TDD, 700 MHz FDD
LTE: 2.6GHz/1800MHz/800MHz FDD | 2.6GHz/1800MHz/800MHz FDD | FR1 - 3.7 GHz TDD, 700 MHz FDD | FR2 - 26 GHz TDD | +| Figure Reference | Figure A-1 | Figure A-1 | Figure A-2 | Figure A-2 | Figure A-3 | +| Reference to WG6 CAD [4] | Based on Scenario A in Appendix 7.1 | Based on Scenario A in Appendix 7.1 | Based on Scenario A in Section 6.1 | Based on Scenario A in Section 6.1 | Based on Scenario E in Section 6.1 | + +![Figure A-1: Operator #1 Deployment Scenario #1 – NSA (FR1). This diagram shows the architecture for NSA (FR1) across three domains: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains O-RU, O-eNB, and RU/RRH. The Edge Cloud contains xApp, Near RT RIC, O-DU [NR], O-CU-CP/UP [NR], O-DU [LTE], and CU [LTE]. The Regional Cloud contains SMO and Non-RT RIC. Interfaces include WG4 M-Plane (Hybrid) / O1, OFH1, OFH2, E2, F1, X2/Xn, and A1. A legend indicates E2E System under Test, Subsystem under Test, Management Interfaces, Out of Scope in this specification, and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'.](c1ad6966d7bf54e2d84b918ae152c182_img.jpg) + +Figure A-1: Operator #1 Deployment Scenario #1 – NSA (FR1). This diagram shows the architecture for NSA (FR1) across three domains: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains O-RU, O-eNB, and RU/RRH. The Edge Cloud contains xApp, Near RT RIC, O-DU [NR], O-CU-CP/UP [NR], O-DU [LTE], and CU [LTE]. The Regional Cloud contains SMO and Non-RT RIC. Interfaces include WG4 M-Plane (Hybrid) / O1, OFH1, OFH2, E2, F1, X2/Xn, and A1. A legend indicates E2E System under Test, Subsystem under Test, Management Interfaces, Out of Scope in this specification, and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +**Figure A-1: Operator #1 Deployment Scenario #1 – NSA (FR1)** + +Note: W1 is specified in 3GPP Release 16 for ng-eNB only. + +Refer to [4][11][12] for more details on the FHGW. + +![Figure A-2: Operator #1 Deployment Scenario #2 – SA (FR1). This diagram shows the architecture for SA (FR1) across three domains: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains O-RU, O-eNB, and RU/RRH. The Edge Cloud contains xApp, Near RT RIC, O-DU [NR], O-CU-CP/UP [NR], O-DU [LTE], and CU [LTE]. The Regional Cloud contains SMO and Non-RT RIC. Interfaces include WG4 M-Plane (Hybrid) / O1, OFH1, OFH2, E2, F1, X2/Xn, and A1. A legend indicates E2E System under Test, Subsystem under Test, Management Interfaces, Out of Scope in this specification, and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'.](03f828d91e77a946ce3f49835b6c5e6d_img.jpg) + +Figure A-2: Operator #1 Deployment Scenario #2 – SA (FR1). This diagram shows the architecture for SA (FR1) across three domains: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains O-RU, O-eNB, and RU/RRH. The Edge Cloud contains xApp, Near RT RIC, O-DU [NR], O-CU-CP/UP [NR], O-DU [LTE], and CU [LTE]. The Regional Cloud contains SMO and Non-RT RIC. Interfaces include WG4 M-Plane (Hybrid) / O1, OFH1, OFH2, E2, F1, X2/Xn, and A1. A legend indicates E2E System under Test, Subsystem under Test, Management Interfaces, Out of Scope in this specification, and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +**Figure A-2: Operator #1 Deployment Scenario #2 – SA (FR1)** + +![Figure A-3: Operator #1 Deployment Scenario #3 – SA (FR2). This diagram shows the architecture for SA (FR2) across three domains: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains O-RU, O-DU [NR], and RU/RRH. The Edge Cloud contains xApp, Near RT RIC, O-DU [NR], O-CU-CP/UP [NR], and CU [LTE]. The Regional Cloud contains SMO and Non-RT RIC. Interfaces include WG4 M-Plane (Hybrid) / O1, OFH1, OFH2, E2, F1, X2/Xn, and A1. A legend indicates E2E System under Test, Subsystem under Test, Management Interfaces, Out of Scope in this specification, and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'.](410b033b9d4c6f2e81e9bca9c4b36c58_img.jpg) + +Figure A-3: Operator #1 Deployment Scenario #3 – SA (FR2). This diagram shows the architecture for SA (FR2) across three domains: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains O-RU, O-DU [NR], and RU/RRH. The Edge Cloud contains xApp, Near RT RIC, O-DU [NR], O-CU-CP/UP [NR], and CU [LTE]. The Regional Cloud contains SMO and Non-RT RIC. Interfaces include WG4 M-Plane (Hybrid) / O1, OFH1, OFH2, E2, F1, X2/Xn, and A1. A legend indicates E2E System under Test, Subsystem under Test, Management Interfaces, Out of Scope in this specification, and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +**Figure A-3: Operator #1 Deployment Scenario #3 – SA (FR2)** + +**Table A-2: Operator #1 inputs – Subsystem O-RU** + +| O-RU | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|--------------------------------------------------------------|-------------------------------------|-------------------|-----------------|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Separated / Integrated O-DU and O-RU | Separated: WG4: OFH | | | |

Integrated or Separated.

In the case if the O-DU and O-RU are integrated, OFH is not available for testing.

In the case if the O-DU and O-RU are implemented as separate nodes and they can either be co-located in the same or distributed locations – WG4: OFH.

| +| Management Plane (WG4 M Plane Hierarchical, Hybrid mode, O1) | WG4: M-Plane specification; WG1: O1 | | | | | +| PNF, VNF, CNF | PNF | | | | | +| Location | Cell Site | | | | | + +**Table A-3: Operator #1 inputs – Subsystem FHGW** + +| FHGW | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|------------------------------|------------------------------------|-------------------|-----------------|-----------------|--------------------------------------------| +| 7-2x <-> 7-2x;
7-2x <-> 8 | 7-2x <-> 7-2x;
7-2x <-> 8 (LTE) | - | - | 7-2x <-> 7-2x | 7-2x <-> 7-2x
(if DU-RU not integrated) | + +**Table A-4: Operator #1 inputs – Subsystem O-DU** + +| O-DU | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|--------------------------------------|-----------------------|-------------------|-----------------|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Separated / Integrated O-DU and O-RU | Separated
WG4: OFH | | | |

Integrated or Separated.

In the case if the O-DU and O-RU are integrated, OFH is not available for testing.

In the case if the O-DU and O-RU are implemented as separate nodes and they can either be co-located in the same or distributed locations – WG4: OFH.

| + +| O-DU | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|-----------------------------------------------------------------|-------------------------------------|--------------------------|----------------------|----------------------|----------------------| +| Separated / Integrated O-DU and O-CU-CP/O-CU-UP | Separated
WG5: F1, W1 | Separated
WG5: F1, W1 | Separated
WG5: W1 | Separated
WG5: F1 | Separated
WG5: F1 | +| Management Plane (WG4 M Plane Hierarchical, Hybrid mode, O1) | WG4: M-Plane specification; WG1: O1 | | | | | +| PNF, VNF, CNF | WG6: VNF, CNF | | | | PNF | +| O-Cloud | WG6: O2 | | | | N/A | +| Location (Cell, Edge site) | WG6: Edge | | | | Cell | +| Near-Real time RIC support (counters and stats perspective, E2) | WG3: E2 | | | | | + +**Table A-5: Operator #1 inputs – Subsystem O-CU-CP/ O-CU-UP** + +| O-CU-CP /O-CU-UP | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | | | | | +|-----------------------------------------------------------------|--------------------------|--------------------------|----------------------|----------------------|----------------------|--|--|--|--| +| Management | WG1: O1 | | | | | | | | | +| Separated / Integrated / O-DU and O-CU-CP/O-CU-UP | Separated
WG5: F1, W1 | Separated
WG5: F1, W1 | Separated
WG5: W1 | Separated
WG5: F1 | Separated
WG5: F1 | | | | | +| PNF, VNF, CNF | WG6: VNF, CNF | | | | | | | | | +| O-Cloud | WG6: O2 | | | | | | | | | +| NR Deployment Options (NSA Option 3x, SA Option 2, others) | WG5: X2 (NSA) | WG5: Xn (SA) | | | | | | | | +| Location (Edge, Regional site) | WG6: Edge | | | | | | | | | +| Near-Real time RIC support (counters and stats perspective, E2) | WG3: E2 | | | | | | | | | + +**Table A-6: Operator #1 inputs – Subsystem O-eNB** + +| O-eNB | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|---------------|-------------------|-------------------|-----------------|-----------------|-----------------| +| Management | WG1: O1 | | | N/A | N/A | +| PNF, VNF, CNF | WG6: VNF, CNF | | | N/A | N/A | +| O-Cloud | WG6: O2 | | | N/A | N/A | + +| O-eNB | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|-----------------------------------------------------------------|------------------------|-------------------|-----------------|-----------------|-----------------| +| NR Deployment Options (NSA Option 3x, SA Option 2, others) | WG5: Xn (SA), X2 (NSA) | | WG5: Xn (SA) | N/A | N/A | +| Location (Cell, Edge, Regional site) | WG6: Edge | | | N/A | N/A | +| Near-Real time RIC support (counters and stats perspective, E2) | WG3: E2 | | | N/A | N/A | + +**Table A-7: Operator #1 inputs – Subsystem O-Cloud** + +| O-Cloud | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|--------------------------------------|---------------------|-------------------|-----------------|-----------------|-----------------| +| Management | WG6: O2 | | | | | +| Location (Cell, Edge, Regional site) | WG6: Edge, Regional | | | | | + +**Table A-8: Operator #1 inputs – Subsystem Near-Real Time RIC** + +| Near-Real Time RIC | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|----------------------------------------------|----------------------------------------------------------------|-------------------|-----------------|-----------------|-----------------| +| Base functions | WG3: E2, xApp; WG2: A1 | | | | | +| PNF, VNF, CNF | WG6: VNF, CNF | | | | | +| O-Cloud | WG6: O2 | | | | | +| Location (Edge, Regional site) | WG6: Edge | | | | | +| xApps | Traffic Steering, QoE/QoS | | | | | +| Advanced use cases (such as Network Slicing) | Massive MIMO Beamforming Optimization (WG1), RAN sharing (WG1) | | | | | + +**Table A-9: Operator #1 inputs – Subsystem Non-Real Time RIC** + +| Non-Real Time RIC | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|--------------------------------|-------------------|-------------------|-----------------|-----------------|-----------------| +| Base functions | WG2: A1 | | | | | +| PNF, VNF, CNF | WG6: VNF, CNF | | | | | +| Location (Edge, Regional site) | WG6: Regional | | | | | + +**Table A-10: Operator #1 inputs – Subsystem SMO** + +| SMO | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|----------------|-------------------|-------------------|-----------------|-----------------|-----------------| +| Base functions | WG1: O1 | | | | | + +**Table A-11: Operator #1 inputs – Subsystem xApp** + +| xApps | NSA Opt. 3x (FR1) | NSA Opt. 7x (FR1) | SA Opt. 5 (FR1) | SA Opt. 2 (FR1) | SA Opt. 2 (FR2) | +|-----------|---------------------------|-------------------|-----------------|-----------------|-----------------| +| WG3 xApps | Traffic Steering, QoE/QoS | | | | | + +## A.2 Operator #2 inputs + +### Deployment Scenario + +1. Indoors Small Cell +2. 5G NR FR1 2.6GHz, 4.9GHz – TDD +3. Maximum Channel Bandwidth (CHBW) 100MHz +4. Leverages WG4 Shared Cell feature with combination of both FHM and Cascade modes + +### Deployment Options and Evolution + +1. NR NSA Option 3x +2. NR SA Option 2 + +### Subsystems + +1. Phase 1: O-RU, FHGW, O-DU/O-CU-CP/O-CU-UP (integrated unit) and Server +2. Phase 2: O-RU, FHGW, O-DU/O-CU-CP/O-CU-UP (integrated unit), AAL and Server + +Refer to [4][11][12] for more details on the FHGW. + +![Figure A-4: Operator #2 Deployment Scenario #1 (FR1) – Phase 1. This diagram illustrates the network architecture for Phase 1 of the deployment. It shows three main components: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains an RRU Subsystem with RU and FHGW (optional) blocks, and two O-RU blocks. The Edge Cloud contains an O-DU/O-CU-CP/O-CU-UP block and a Server. The Regional Cloud contains SMO and NMS blocks. Connections include: O1 interface between Cell Site and Edge Cloud; O1 interface between Edge Cloud and Regional Cloud; OFH1 and OFH2 interfaces between O-RU and FHGW; and a Management Interface between SMO and NMS. A legend at the top defines symbols: E2E System under Test (blue box), Subsystem under Test (green box), Management Interface (orange line), Out of Scope in this specification (dashed line), and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing (grey line). A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'.](ce04fbaa71472de905f15821fc612928_img.jpg) + +Figure A-4: Operator #2 Deployment Scenario #1 (FR1) – Phase 1. This diagram illustrates the network architecture for Phase 1 of the deployment. It shows three main components: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains an RRU Subsystem with RU and FHGW (optional) blocks, and two O-RU blocks. The Edge Cloud contains an O-DU/O-CU-CP/O-CU-UP block and a Server. The Regional Cloud contains SMO and NMS blocks. Connections include: O1 interface between Cell Site and Edge Cloud; O1 interface between Edge Cloud and Regional Cloud; OFH1 and OFH2 interfaces between O-RU and FHGW; and a Management Interface between SMO and NMS. A legend at the top defines symbols: E2E System under Test (blue box), Subsystem under Test (green box), Management Interface (orange line), Out of Scope in this specification (dashed line), and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing (grey line). A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +**Figure A-4: Operator #2 Deployment Scenario #1 (FR1) – Phase 1** + +![Figure A-5: Operator #2 Deployment Scenario #1 (FR1) – Phase 2. This diagram illustrates the architecture for Phase 2 of the deployment. It shows three main components: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains an RRU Subsystem with RU and FHGW (optional) blocks, and O-RU blocks. The Edge Cloud contains vO-DU, vO-CU-CP/UP, and O-Cloud inc. AAL blocks. The Regional Cloud contains SMO and NMS blocks. Management interfaces (orange lines) connect the Cell Site to the Edge Cloud and the Regional Cloud. Out-of-scope interfaces (grey lines) are also shown. The diagram includes a legend for E2E System under Test, Subsystem under Test, Management Interfaces, Out of Scope in this specification, and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'.](87718488ca18f47cd5e14bf3fd1fae10_img.jpg) + +Figure A-5: Operator #2 Deployment Scenario #1 (FR1) – Phase 2. This diagram illustrates the architecture for Phase 2 of the deployment. It shows three main components: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains an RRU Subsystem with RU and FHGW (optional) blocks, and O-RU blocks. The Edge Cloud contains vO-DU, vO-CU-CP/UP, and O-Cloud inc. AAL blocks. The Regional Cloud contains SMO and NMS blocks. Management interfaces (orange lines) connect the Cell Site to the Edge Cloud and the Regional Cloud. Out-of-scope interfaces (grey lines) are also shown. The diagram includes a legend for E2E System under Test, Subsystem under Test, Management Interfaces, Out of Scope in this specification, and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +Figure A-5: Operator #2 Deployment Scenario #1 (FR1) – Phase 2 + +## A.3 Operator #3 inputs + +### Deployment Scenario + +1. Outdoor Macro Cell Deployment +2. 5G NR FR1 n66, n70, n71, n29, n26 +3. Total Channel Bandwidth (CHBW) 150MHz + +### Deployment Options and Evolution + +1. NR SA Option 2 + +### O-RAN Deployment Blueprints variants and corresponding Subsystems + +1. Refer to Figure A-6: O-RU, O-DU at Cell site, O-CU-CP, and O-CU-UP at Regional cloud, AAL and Server +2. Refer to Figure A-7: O-RU, O-DU at Local cloud, O-CU-CP, and O-CU-UP at Regional cloud, AAL and Server + +#### Use Cases focuses + +1. White Box Hardware and Open Interfaces +2. Near-RT RIC (edge-cloud) and Non-RT-RIC Use Cases (Regional cloud): Traffic Steering, QoS /QoE Optimization and Slicing +3. Cloud Deployment + +![Figure A-6: Operator #3 Deployment Scenario #1 (FR1) – Phase 2. This diagram illustrates the architecture for Phase 2 of the deployment. It shows three main components: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains an RRU Subsystem with RU and FHGW (optional) blocks, and O-RU blocks. The Edge Cloud contains vO-DU, vO-CU-CP/UP, and O-Cloud inc. AAL blocks. The Regional Cloud contains SMO, Non-RT RIC, xApp, Near RT RIC, O-CU-CP, and O-CU-UP blocks. Management interfaces (orange lines) connect the Cell Site to the Edge Cloud and the Regional Cloud. Out-of-scope interfaces (grey lines) are also shown. The diagram includes a legend for E2E System under Test, Subsystem under Test, Management Interfaces, Out of Scope in this specification, and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing. A note at the bottom states: 'The circles at both ends of each line indicate the endpoints of each interface'.](7c53b30bc956683048b1ba4ee2844709_img.jpg) + +Figure A-6: Operator #3 Deployment Scenario #1 (FR1) – Phase 2. This diagram illustrates the architecture for Phase 2 of the deployment. It shows three main components: Cell Site, Edge Cloud, and Regional Cloud. The Cell Site contains an RRU Subsystem with RU and FHGW (optional) blocks, and O-RU blocks. The Edge Cloud contains vO-DU, vO-CU-CP/UP, and O-Cloud inc. AAL blocks. The Regional Cloud contains SMO, Non-RT RIC, xApp, Near RT RIC, O-CU-CP, and O-CU-UP blocks. Management interfaces (orange lines) connect the Cell Site to the Edge Cloud and the Regional Cloud. Out-of-scope interfaces (grey lines) are also shown. The diagram includes a legend for E2E System under Test, Subsystem under Test, Management Interfaces, Out of Scope in this specification, and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing. A note at the bottom states: 'The circles at both ends of each line indicate the endpoints of each interface'. + +Figure A-6: Operator #3 Deployment Scenario #1 – SA (FR1) + +![Figure A-6: Operator #3 Deployment Scenario #1 – SA (FR1). This diagram illustrates the network architecture across three domains: Cell Site, Edge Cloud, and Regional Cloud. In the Cell Site, two O-RU units are connected to a Switch (Optional). Management interfaces (OFH1, OFH2) connect the O-RUs to the O-DU in the Edge Cloud. The O-DU is connected to the O-CU-CP and O-CU-UP in the Regional Cloud via F1-C and F1-U interfaces. The Regional Cloud also contains an SMO, Non-RT RIC, and Near RT RIC, connected via A1 and E2 interfaces. The diagram includes a legend for E2E System under Test, Subsystem under Test, Management Interfaces, and Out of Scope in this specification. It also notes CUS-Plane and M-Plane (Hierarchical) connections.](1888ee625428705c060330e16bdc98e4_img.jpg) + +Figure A-6: Operator #3 Deployment Scenario #1 – SA (FR1). This diagram illustrates the network architecture across three domains: Cell Site, Edge Cloud, and Regional Cloud. In the Cell Site, two O-RU units are connected to a Switch (Optional). Management interfaces (OFH1, OFH2) connect the O-RUs to the O-DU in the Edge Cloud. The O-DU is connected to the O-CU-CP and O-CU-UP in the Regional Cloud via F1-C and F1-U interfaces. The Regional Cloud also contains an SMO, Non-RT RIC, and Near RT RIC, connected via A1 and E2 interfaces. The diagram includes a legend for E2E System under Test, Subsystem under Test, Management Interfaces, and Out of Scope in this specification. It also notes CUS-Plane and M-Plane (Hierarchical) connections. + +Figure A-7: Operator #3 Deployment Scenario #2 – SA (FR1) + +## A.4 Operator #4 inputs + +### Deployment Scenario + +1. Outdoor Small Cell, Outdoor Macro Cell, Indoors Small Cell +2. 5G NR FR1 TDD (3.7GHz, 4.5GHz), 5G NR FR2 TDD (28GHz) +3. Maximum Channel Bandwidth (CHBW) 100MHz for FR1 and 400MHz for FR2 + +### Deployment Blueprints variants and corresponding Subsystems + +Table A-12: Operator #4 inputs – Deployment Blueprint variants + +| Deployment variants | NSA Opt. 3x (NSA1) | NSA Opt. 3x (NSA2) | SA Opt. 2 (SA1) | NSA Opt. 3x (NSA3) | NSA Opt. 3x (NSA4) | SA Opt. 2 (SA2) | +|--------------------------|---------------------------------------|----------------------------------------------------------|---------------------------------------|---------------------------------------|----------------------------------------------------------------------|--------------------------------------------------------------| +| Subsystems | O-RU, Integrated O-DU/O-CU-CP/O-CU-UP | O-RU, Integrated O-DU/O-CU-CP/O-CU-UP, (Shared Cell) FHM | O-RU, Integrated O-DU/O-CU-CP/O-CU-UP | Integrated O-RU/O-DU, O-CU-CP/O-CU-UP | O-RU, Integrated O-DU/O-CU-CP/O-CU-UP, Near-RT RIC, xApps, SMO | O-RU, Integrated O-DU/O-CU-CP/O-CU-UP, O-Cloud, SMO | +| Interfaces under Test | X2, OFH, WG4 M-Plane Hierarchical | X2, OFH, WG4 M-Plane Hierarchical | OFH, WG4 M-Plane Hierarchical | X2, F1 | X2, OFH, WG4 M-Plane Hierarchical, A1
E2 is an internal interface | OFH, WG4 M-Plane Hierarchical, O1, O2, O-Cloud APIs | +| PNF, VNF | All PNFs | All PNFs | All PNFs | All PNFs | All PNFs | Virtualized Integrated O-DU/O-CU-CP/O-CU-UP
Rest are PNFs | +| Figure Reference | Figure A-8 | Figure A-8 | Figure A-9 | Figure A-10 | Figure A-11 | Figure A-12 | +| Reference to WG6 CAD [4] | Based on Scenario A in Appendix 7.1 | Based on Scenario A in Appendix 7.1 | Based on Scenario A/B in Section 6.1 | Based on Scenario A/B in Appendix 7.1 | Based on Scenario A in Appendix 7.1 | Based on Scenario A/B in Section 6.1 | + +![Figure A-8: Operator #4 Deployment Scenario #1 – NSA. This diagram shows the architecture for NSA deployment. It is divided into three main sections: Cell Site, Edge Site, and Regional Site. In the Cell Site, there is an 'O-RU [NR]' and 'RU/RRH'. In the Edge Site, there is an 'FHM (Optional)', 'O-DU/O-CU-CP / O-CU-UP [NR]', and 'eNB'. In the Regional Site, there is an 'NMS'. Interfaces are shown: OFH1 and OFH2 between O-RU and FHM; OFH1 and OFH2 between FHM and O-DU/O-CU-CP; X2 between O-DU/O-CU-CP and eNB. A legend at the top indicates: E2E System under Test (blue box), Subsystem under Test (green box), Management Interface (orange line), Out of Scope in this specification (grey line), and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing (grey line with dots). A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'.](9028c32165bb5a73aa33e052a3403bc0_img.jpg) + +Figure A-8: Operator #4 Deployment Scenario #1 – NSA. This diagram shows the architecture for NSA deployment. It is divided into three main sections: Cell Site, Edge Site, and Regional Site. In the Cell Site, there is an 'O-RU [NR]' and 'RU/RRH'. In the Edge Site, there is an 'FHM (Optional)', 'O-DU/O-CU-CP / O-CU-UP [NR]', and 'eNB'. In the Regional Site, there is an 'NMS'. Interfaces are shown: OFH1 and OFH2 between O-RU and FHM; OFH1 and OFH2 between FHM and O-DU/O-CU-CP; X2 between O-DU/O-CU-CP and eNB. A legend at the top indicates: E2E System under Test (blue box), Subsystem under Test (green box), Management Interface (orange line), Out of Scope in this specification (grey line), and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing (grey line with dots). A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +**Figure A-8: Operator #4 Deployment Scenario #1 – NSA** + +![Figure A-9: Operator #4 Deployment Scenario #2 – SA. This diagram shows the architecture for SA deployment. It is divided into three main sections: Cell Site, Edge Cloud, and Regional Site. In the Cell Site, there is an 'O-RU [NR]'. In the Edge Cloud, there is an 'O-DU/O-CU-CP / O-CU-UP [NR]'. In the Regional Site, there is an 'NMS'. Interfaces are shown: OFH1 and OFH2 between O-RU and O-DU/O-CU-CP. A legend at the top indicates: E2E System under Test (blue box), Subsystem under Test (green box), Management Interface (orange line), Out of Scope in this specification (grey line), and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing (grey line with dots). A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'.](60267c4dbb6f9023b9ec29911cea785c_img.jpg) + +Figure A-9: Operator #4 Deployment Scenario #2 – SA. This diagram shows the architecture for SA deployment. It is divided into three main sections: Cell Site, Edge Cloud, and Regional Site. In the Cell Site, there is an 'O-RU [NR]'. In the Edge Cloud, there is an 'O-DU/O-CU-CP / O-CU-UP [NR]'. In the Regional Site, there is an 'NMS'. Interfaces are shown: OFH1 and OFH2 between O-RU and O-DU/O-CU-CP. A legend at the top indicates: E2E System under Test (blue box), Subsystem under Test (green box), Management Interface (orange line), Out of Scope in this specification (grey line), and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing (grey line with dots). A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +**Figure A-9: Operator #4 Deployment Scenario #2 – SA** + +![Figure A-10: Operator #4 Deployment Scenario #3 – NSA. This diagram shows the architecture for NSA deployment. It is divided into three main sections: Cell Site, Edge Site, and Regional Site. In the Cell Site, there is an 'O-RU / O-DU [NR]' and 'RU/RRH'. In the Edge Site, there is an 'O-CU-CP / O-CU-UP [NR]' and 'eNB'. In the Regional Site, there is an 'NMS'. Interfaces are shown: F1 between O-RU / O-DU and O-CU-CP / O-CU-UP; X2 between O-CU-CP / O-CU-UP and eNB. A legend at the top indicates: E2E System under Test (blue box), Subsystem under Test (green box), Management Interface (orange line), Out of Scope in this specification (grey line), and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing (grey line with dots). A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'.](31bc8f4b672b01aecc0eaf4ca72692cf_img.jpg) + +Figure A-10: Operator #4 Deployment Scenario #3 – NSA. This diagram shows the architecture for NSA deployment. It is divided into three main sections: Cell Site, Edge Site, and Regional Site. In the Cell Site, there is an 'O-RU / O-DU [NR]' and 'RU/RRH'. In the Edge Site, there is an 'O-CU-CP / O-CU-UP [NR]' and 'eNB'. In the Regional Site, there is an 'NMS'. Interfaces are shown: F1 between O-RU / O-DU and O-CU-CP / O-CU-UP; X2 between O-CU-CP / O-CU-UP and eNB. A legend at the top indicates: E2E System under Test (blue box), Subsystem under Test (green box), Management Interface (orange line), Out of Scope in this specification (grey line), and Out of Scope for O-RAN Subsystem and Subsystem Pair Open Interfaces Testing (grey line with dots). A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +**Figure A-10: Operator #4 Deployment Scenario #3 – NSA** + +![Figure A-11: Operator #4 Deployment Scenario #4 – NSA. This diagram illustrates the network architecture for NSA (Non-Standalone) deployment. It shows three main sites: Cell Site, Edge Site, and Regional Site. The Cell Site contains an O-RU [NR] and RU/RRH. The Edge Site contains a Near-RT RIC (xApp) and O-DU/O-CU-CP/O-CU-UP [NR]. The Regional Site contains an SMO (Service Based Interface), Non-RT RIC, and NMS. Interfaces include OFH1, OFH2, O1, A1, E2, and X2. A legend indicates that orange lines represent Management Interfaces, and grey lines represent Out of Scope interfaces. A note states: 'The circles at both ends of each line indicates the endpoints of each interface'.](565dd18bba42c55b8c5a3b3ae5be942f_img.jpg) + +●—● The circles at both ends of each line indicates the endpoints of each interface + +Figure A-11: Operator #4 Deployment Scenario #4 – NSA. This diagram illustrates the network architecture for NSA (Non-Standalone) deployment. It shows three main sites: Cell Site, Edge Site, and Regional Site. The Cell Site contains an O-RU [NR] and RU/RRH. The Edge Site contains a Near-RT RIC (xApp) and O-DU/O-CU-CP/O-CU-UP [NR]. The Regional Site contains an SMO (Service Based Interface), Non-RT RIC, and NMS. Interfaces include OFH1, OFH2, O1, A1, E2, and X2. A legend indicates that orange lines represent Management Interfaces, and grey lines represent Out of Scope interfaces. A note states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +Figure A-11: Operator #4 Deployment Scenario #4 – NSA + +![Figure A-12: Operator #4 Deployment Scenario #5 – SA. This diagram illustrates the network architecture for SA (Standalone) deployment. It shows three main sites: Cell Site, Edge Cloud, and Regional Site. The Cell Site contains an O-RU [NR]. The Edge Cloud contains O-DU/O-CU-CP/O-CU-UP [NR] and O-Cloud APIs. The Regional Site contains an SMO. Interfaces include OFH1, OFH2, O1, and O2. A legend indicates that orange lines represent Management Interfaces, and grey lines represent Out of Scope interfaces. A note states: 'The circles at both ends of each line indicates the endpoints of each interface'.](c5ef9409d26ded005d68c9026b489852_img.jpg) + +●—● The circles at both ends of each line indicates the endpoints of each interface + +Figure A-12: Operator #4 Deployment Scenario #5 – SA. This diagram illustrates the network architecture for SA (Standalone) deployment. It shows three main sites: Cell Site, Edge Cloud, and Regional Site. The Cell Site contains an O-RU [NR]. The Edge Cloud contains O-DU/O-CU-CP/O-CU-UP [NR] and O-Cloud APIs. The Regional Site contains an SMO. Interfaces include OFH1, OFH2, O1, and O2. A legend indicates that orange lines represent Management Interfaces, and grey lines represent Out of Scope interfaces. A note states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +Figure A-12: Operator #4 Deployment Scenario #5 – SA + +# Annex B: O-RAN Software Community inputs on Testing Methodology + +This annex provides an overview on the O-RAN Software Community (OSC) work and its current software releases and testing practices. Refer to the OSC wiki site for the most current information (). + +The O-CU referred in this annex should be considered as O-CU CP/UP. + +## B.1 O-RAN Software Community + +The O-RAN Software Community (OSC) is an open source software development project aimed at providing an open source implementation of an end-to-end RAN system following O-RAN Alliance architecture and specifications. The OSC is hosted by the Linux Foundation and funded by the O-RAN Alliance. + +The OSC is led by a 12-member Technical Oversight Committee (TOC) with its current members representing AT&T, China Mobile, Deutsche Telekom, Ericsson, Nokia, NTT DOCOMO, Orange, Radisys and Verizon. + +The working effort of the OSC is organized into the following development projects: + +- Operations and Maintenance (OAM) +- Non-Realtime RAN Intelligent Controller (NONRTRIC) +- Near-Realtime RAN Intelligent Controller Platform (RIC) +- Near-Realtime RAN Intelligent Controller Applications (RICAPP) +- O-RAN Central Unit (OCU) +- O-RAN Distributed Unit High (ODUHIGH) +- O-RAN Distributed Unit LOW (ODULOW) +- Simulations (SIM) +- Infrastructure (INF) +- Documentation (DOC) +- Integration and Testing (INT) + +and subcommittee(s) + +- Requirements and Software Architecture Committee (RSAC) + +The OSC conducts its business on open communication and development platforms including Zoom teleconferencing bridge, Groups.io mailing lists, Confluence wiki, and Git/Gerrit source code repositories. All O-RAN SC information and O-RAN SC developed software can be accessed via resources listed in Annex B.6. + +## B.2 OSC Development Cycles + +The OSC developed software is released on a bi-annual schedule, first in May/June time frame and the second in November/December. The naming scheme of releases follows color names in alphabetical order, with individual release names selected by community member voting. The first four releases are named Amber, Bronze, Cherry, and Dawn. The OSC delivered its first release, Amber release, in November 2019. + +The high-level objectives and use cases for the next release are usually selected by the RSAC during the later portion of the current release cycle. The first several weeks of each release cycle typically are for the design and planning phase where the high-level release objectives are designed into implementable features and tasks, which are distributed to the OSC development projects. Following the planning phase is the development phase, during which the development projects and teams implement the agreed-upon features. This phase is divided into three-week sprints where each sprint has its own more manageable implementation and testing goals. Finally, prior to the release of the software, it is the testing phase, during which the integrated system testing and end-to-end use case testing are conducted, and the viability and quality of the software are verified and evaluated. + +After each release, the OSC also institutes a maintenance window for the new release during the design and planning phase of the next release cycle. Normally this time window is used only for fixing major problems discovered after the release. + +## B.3 OSC Software and Test Deployment Architecture + +The OSC projects are set up based on the O-RAN Alliance architecture. + +Figure B-1 below shows the relationship between OSC projects and the O-RAN architecture components. + +![Figure B-1: Relationship between OSC projects and the O-RAN architecture components. The diagram shows a vertical stack of O-RAN architecture components on the left: SMO, Near RT RIC, O-CU, O-DU, and O-RU. To the right, OSC projects are mapped to these components: Non RT RIC and OAM map to SMO; (Near)RT RIC Platform and (Near)RT RIC Applications map to Near RT RIC; O-CU maps to O-CU; O-DU HIGH and O-DU LOW map to O-DU; and O-RU maps to O-RU. Interconnecting interfaces are shown: INF (Inter-Function) interfaces connect the components horizontally and vertically; INT (Inter-NodeB) and DOC (Data Object) interfaces connect the components to the right.](a0e3dd059b2b008183fc3324fbba6313_img.jpg) + +Figure B-1: Relationship between OSC projects and the O-RAN architecture components. The diagram shows a vertical stack of O-RAN architecture components on the left: SMO, Near RT RIC, O-CU, O-DU, and O-RU. To the right, OSC projects are mapped to these components: Non RT RIC and OAM map to SMO; (Near)RT RIC Platform and (Near)RT RIC Applications map to Near RT RIC; O-CU maps to O-CU; O-DU HIGH and O-DU LOW map to O-DU; and O-RU maps to O-RU. Interconnecting interfaces are shown: INF (Inter-Function) interfaces connect the components horizontally and vertically; INT (Inter-NodeB) and DOC (Data Object) interfaces connect the components to the right. + +**Figure B-1: Relationship between OSC projects and the O-RAN architecture components** + +Figure B-2 depicts how the delivered software components by the OSC projects are deployed in the OSC Integration and Testing lab for Bronze release testing. + +The deployment is spread across two Kubernetes clusters and two bare metal servers. From right to left, the first Kubernetes cluster is the SMO cluster, for components developed by the Non-Realtime RIC and OAM projects. The second Kubernetes cluster is the RIC cluster, for deploying components and microservices developed by the Near Realtime RIC Platform and the Near-Realtime RIC Applications projects. One of the bare-metal servers is used for running O-DU (both O-DO LOW and O-DU HIGH), and the other for running O-RU stub for peering the Open Fronthaul connection to the O-DU, over a dedicated 40GE link. + +![Figure B-2: Deployment of OSC projects components in the OSC Integration and Testing lab for Bronze release. The diagram shows a multi-tier architecture. On the left, O-RU Server and O-DU Server are shown with O-RU Stub, O-DU LOW, and O-DU HIGH components. These connect to a central stack of layers: PTI, Bare metal, Docker, K8S, and a Docker host running Ubuntu 18.04. The main part of the diagram is divided into two clusters: 'Near RT RIC Cluster' and 'SMO Cluster'. The Near RT RIC Cluster contains components like MC, KPI Mon, HelloWorld, Traffic Steering, QP, QP Driver, rioxapp ns, Prometheus AM, and rioxinfra ns. The SMO Cluster contains components like onap ns, ONAP VES, ONAP DMAAP MR, ONAP SDNR, ONAP MSB, Consul, Maria DB, nonrtic ns, Policy/MgmtServ, Control Panel, A1 Controller, A1 Simulator, riox ns, RIC Dashboard, Elastic Search, LogStash, and Kibana. A legend on the right titled 'OSC Project' shows a stack of colored boxes representing different project layers: OAM (green), NonRT RIC (orange), NearRT RIC (blue), xApp (light blue), NearRT RIC Platform (dark blue), O-DU HIGH (yellow), O-DU LOW (light green), and INF (purple). IPv4 connections are indicated at the bottom.](c8214cd9d6a6cca9090cc644f55ce18e_img.jpg) + +Figure B-2: Deployment of OSC projects components in the OSC Integration and Testing lab for Bronze release. The diagram shows a multi-tier architecture. On the left, O-RU Server and O-DU Server are shown with O-RU Stub, O-DU LOW, and O-DU HIGH components. These connect to a central stack of layers: PTI, Bare metal, Docker, K8S, and a Docker host running Ubuntu 18.04. The main part of the diagram is divided into two clusters: 'Near RT RIC Cluster' and 'SMO Cluster'. The Near RT RIC Cluster contains components like MC, KPI Mon, HelloWorld, Traffic Steering, QP, QP Driver, rioxapp ns, Prometheus AM, and rioxinfra ns. The SMO Cluster contains components like onap ns, ONAP VES, ONAP DMAAP MR, ONAP SDNR, ONAP MSB, Consul, Maria DB, nonrtic ns, Policy/MgmtServ, Control Panel, A1 Controller, A1 Simulator, riox ns, RIC Dashboard, Elastic Search, LogStash, and Kibana. A legend on the right titled 'OSC Project' shows a stack of colored boxes representing different project layers: OAM (green), NonRT RIC (orange), NearRT RIC (blue), xApp (light blue), NearRT RIC Platform (dark blue), O-DU HIGH (yellow), O-DU LOW (light green), and INF (purple). IPv4 connections are indicated at the bottom. + +Figure B-2: Deployment of OSC projects components in the OSC Integration and Testing lab for Bronze release + +## B.4 OSC Release Objectives + +### Amber (achieved) + +- O-RAN SC level + - Continuous Integration (CI) flow implemented and all source code repositories integrated into the CI auto building process. + - Source code repositories build into binary artifacts (i.e. docker container images, libraries, OS ISO media). + - Documentation framework established, initial documentation in place. +- Selected projects + - Near-Real Time RIC Platform and Near-Real Time RIC Applications: + - “one-click” deployable. + - Completing xApp deployment flow, (pre-spec) E2 setup and subscription flow. + +### Bronze (work in progress) + +- O-RAN SC level + - Unit Test and SONAR reporting framework established. + - All participating projects “one-click” deployable. + - RSAC use cases: + - Health-check: including A1 and (pre-spec) O1 health check. + - Traffic Steering: steering decision based on E2 information and AI/ML algorithm. + - O-DU integration: O-DU HIGH communicate with O-DU LOW via FAPI. + +## B.5 OSC Testing + +OSC testing effort is divided into five levels + +1. Unit testing (UT) + - UT is performed by the developers by implementing test cases using programming language specific unit testing and static code analysis framework. + +- UT is triggered automatically every time when there is source code change submitted into the code repository for review. + - At OSC level the INT project team provides support for unit test and code scan (i.e. static code analysis) integration into Linux Foundation Continuous Integration flow, and result reporting into the SONAR Cloud platform. Using the reports, TOC sets quality gates such as percentage of code covered by unit test cases, no major issues discovered, etc. +2. Project level integrated testing (PIT) + - Each development project is expected to conduct project level integrated testing, where all software components developed by the project are deployed into a single system for testing internal flows. + - PIT is expected to be conducted by individual project teams, at the end of each development sprints or other development milestones. + - At OSC level the INT project team organizes sprint demonstration fests regularly where development project teams gather and demonstrate achieved features in the previous sprint, using project level system deployment in project team's own testing and demonstration environment. + - The INT project team is also working with individual development projects on Robot testing framework-based testing flows that are to be integrated into Linux Foundation Continuous Integration flow. Such test flows serve as regression tests for implementation updates and can be triggered automatically by the CI system on a regular basis (e.g. daily) or upon new code submission. + 3. Project pairwise testing (PPT) + - For projects that deliver O-RAN architectural components that interact with each other, PPT is conducted to ensure communication compatibility. + - PPT sessions are organized by the INT project team, using either community testing lab or self-arrange testing facilities by involved projects. + 4. System integrated testing (SIT) + - SIT is whole OSC software testing where all OSC development components are deployed into a single system. SIT focuses on overall system health, inter-project communication and application compatibility, overall system deployment flow, and resource requirements. + - SIT is conducted by the INT project team using OSC community testing lab. + - SIT is conducted during the testing phase of each release cycle. + - Robot test framework-based health check test flows used as automated regression test. + 5. Use case testing (UCT) + - UCT is whole OSC software testing where all OSC development components are deployed into a single system. UCT tests OSC deployment that has passed SIT. + - UCT is conducted by the INT project team using OSC community testing lab. + - UCT is conducted during the testing phase of each release cycle. + - UCT uses Open Testing Framework (OTF), a test flow definition and orchestration tool that is developed as a sub-project under the INT. + +## B.6 References + +1. OSC Resources + - a) Wiki: + - b) Source code: + - c) Project management: + - d) Docker image registry: [nexus3.o-ran-sc.org](https://nexus3.o-ran-sc.org):10004 and [nexus3.o-ran-sc.org](https://nexus3.o-ran-sc.org):10002 + - e) SONAR reporting: + - f) Mailing lists: + - g) Meeting calendar: (member sign-in required) +2. Robot Framework: + +# Annex C: Test Functions, Tools and Solutions for Subsystem and E2E System Testing + +Table C-1 shows an example listing of the test functions, tools and solutions which can be used to establish test bed setups for Subsystem testing, Subsystem Pairing and Open Interfaces Interoperability testing and E2E System testing of the O-RAN Deployment Blueprints. + +These test functions and test tools are classified into the following categories as they can be used for setting up the test environment, providing active stimulus functions and passive measurements for test results verification purposes. + +1. **Test Case Scenario Creation:** used to setup the testing environment and the necessary testing conditions which are required for executing the test case. +2. **Test Case Validation:** used to collect measurements, KPIs, logs, packet captures for verifying, substantiating, troubleshooting, and debugging test results. + +A single test function and tool can be used for both Test Case Scenario Creation and Test Case Validation. + +Few notes for clarification purposes on the example listings of test functions and tools listed in this Annex C + +1. These are non-exhaustive listings i.e. test functions and tools which are not listed in this Annex C can be used where appropriate. +2. Not all the test functions and tools listed will be required for all test scenarios and test cases. +3. Test functions and tools listed can be implemented each as a standalone test tool or multiple of these test functions can be combined into a single test tool. +4. Few of the test functions might be combined into a single test tool (standalone test function usage is not possible). +5. Real or emulated network elements / network functions can be used where appropriate. + +This example listing will be expanded in the next release of this specification. + +**Table C-1: Subsystem and System Testing – Example listing of Test Functions and Tools** + +| No. | Test Functions and Tools | Abbreviation | Test Case Scenario Creation | Test Case Validation | Purpose | Subsystem and Subsystem Pairing and Open Interfaces Interoperability Testing | E2E System Test | +|-----|-------------------------------------------------|--------------|-----------------------------|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------|-----------------| +| 1 | Test UEs with Test SIMs
(LTE, NR NSA, NR SA) | Test UE | Yes | Yes | Used for test cases which require UEs interactions with the SUT.

Test UEs are typically UEs which are designed for commercial or testing applications with certain test and diagnostic functions enabled for test and measurements purposes. | Yes | Yes | +| 2 | Multi UEs Emulator
(LTE, NR NSA, NR SA) | M-UE Emu | Yes | Yes | Used for test cases which require UEs interactions with the SUT. | Yes | Yes | +| 3 | Test Core Network | Test Core | Yes | Yes | Used to terminate Test UEs and/or UEs emulator NAS | Yes | Yes | + +| No. | Test Functions and Tools | Abbreviation | Test Case Scenario Creation | Test Case Validation | Purpose | Subsystem and Subsystem Pairing and Open Interfaces Interoperability Testing | E2E System Test | +|-----|-------------------------------------------------|---------------------------------------|-----------------------------|----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------|-----------------| +| | (EPC, NSA EPC, 5GC) | | | | protocol and to support core network procedures required for RAN (SUT) testing.

Test Core Network are typically Core Networks which are designed for commercial applications and can be used for testing the RAN. | | | +| 4 | Core Network Emulator (EPC, NSA EPC, 5GC) | Core Emu | Yes | Yes | Used to terminate Test UEs and/or UEs emulator NAS protocol and to support core network procedures required for RAN (SUT) testing. | Yes | Yes | +| 5 | Test eNB or gNB (NSA, SA) | Test eNB or Test gNB | Yes | Yes | Used for test cases which require eNB or gNB interaction with DUT/SUT. | Yes | Yes | +| 6 | eNB or gNB Emulator (NSA, SA) | eNB Emu or gNB Emu | Yes | Yes | Used for test cases which require eNB or gNB interaction with DUT/SUT. | Yes | Yes | +| 7 | O-RU Emulator testing the O-DU | O-RU OFH Emu | Yes | Yes | Used for test cases which require O-DU Subsystem testing. | Yes | No | +| 8 | O-DU Emulator testing the O-RU | O-DU OFH Emu | Yes | Yes | Used for test cases which require O-RU Subsystem testing. | Yes | No | +| 9 | O-DU Emulator testing the O-CU-CP/O-CU-UP | O-DU F1 Emu | Yes | Yes | Used for test cases which require O-CU-CP/O-CU-UP Subsystem testing. | Yes | No | +| 9 | O-CU-CP/O-CU-UP Emulator testing the O-DU | O-CU-CP/O-CU-UP F1-C/F1-U Emu | Yes | Yes | Used for test cases which require O-DU Subsystem testing (in the case of O-DU is implemented as a standalone O-DU). | Yes | No | +| 10 | E2 Node Emulator (O-CU-CP/O-CU-UP, O-DU) | O-CU-CP/O-CU-UP E2 Emu or O-DU E2 Emu | Yes | Yes | Used for test cases which require Near-Real Time RIC and xApps Subsystems testing. | Yes | No | +| 11 | Application Test Server (aka Traffic Generator) | App Test Svr or Traffic Gen | Yes | Yes | Used for test cases which require bi-directional (downlink and uplink) user plane | Yes | Yes | + +| No. | Test Functions and Tools | Abbreviation | Test Case Scenario Creation | Test Case Validation | Purpose | Subsystem and Subsystem Pairing and Open Interfaces Interoperability Testing | E2E System Test | +|-----|--------------------------------------|-----------------------|-----------------------------|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------|-----------------| +| | | | | | transfer test(s) to be performed between the Application Test Server and Test UEs and/or UEs emulator. | | | +| 12 | Network Impairment Emulator | NW Impair Gen | Yes | No | Used for test cases which require selective packet impairments such as (but not limited to) over the Open Fronthaul (OFH) interface, X2 and others as appropriate. | Yes | Yes | +| 13 | Packet Delay Insertion Generator | Pkt Delay Gen | Yes | No | Used for test cases which require selective insertion of packet delay such as (but not limited to) over the Open Fronthaul (OFH) interface and others as appropriate.

Noting that fixed delay can be managed via a specific length of fiber as well as using dedicated test tool. | Yes | Yes | +| 14 | Transport and Synchronization Tester | Transport Sync Tester | Yes | Yes | Used for test cases which require passive and active testing of transport network across the fronthaul, midhaul, backhaul and sidehaul (Xn, X2) - S-Plane timing and sync verification across all O-RAN components in both subsystem and system test cases. Supports eCPRI testing for O-RU, O-DU, FHM and FTN. | Yes | Yes | +| 15 | RF Attenuators | RF Atten. | Yes | No | Used for test cases which require radio signals attenuation and can also improve impedance match, ensuring power transfer from source to load is optimized. | Yes | Yes | + +| No. | Test Functions and Tools | Abbreviation | Test Case Scenario Creation | Test Case Validation | Purpose | Subsystem and Subsystem Pairing and Open Interfaces Interoperability Testing | E2E System Test | +|-----|---------------------------------------|-------------------------|-----------------------------|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------|-----------------| +| 16 | Channel Emulator | Channel Emu. | Yes | No | Used for test cases which require radio channel emulation / impairments. | Yes | Yes | +| 17 | RF Chamber | RF Chamber | Yes | No | Used for Over the Air (OTA) RF connectivity to the O-RU (where applicable). | Yes | Yes | +| 18 | Spectrum and Signal Analyzer | SpecAn or SigAnalyzer | No | Yes | Used for test cases which require radio signal and spectrum analysis. | Yes | Yes | +| 19 | Signal Creation Software | SCS | Yes | Yes | Used to create waveforms to stimulate NR and LTE test signals. | Yes | No | +| 20 | Signal Generator | SigGen or Sig Generator | Yes | No | Used for test cases which require radio signal generation. | Yes | No | +| 21 | Test UE Logging Tool | Test UE Logger | No | Yes | Used for test results and KPIs reporting when Test UEs is/are used. | Yes | Yes | +| 22 | Protocol Analyzer | Protocol Analyzer | No | Yes | Used for passive monitoring of the Interface under Test (IUT) for test results verification and troubleshooting purposes such as (but not limited to) over the Open Fronthaul (OFH) interface, X2 and others as appropriate.

Test Tool can be split into Packet Capture and Protocol Decoder functions. These capabilities can be implemented as a single integrated test tool or separate test tools. | Yes | Yes | +| 23 | IQ Analyzer | IQA | No | Yes | Used to analyze IQ data on the Fronthaul interface. | Yes | Yes | +| 24 | Network Synchronization Timing Source | NW Sync Timing Source | Yes | No | Used as network timing synchronization source such as the Precision-Time- | Yes | Yes | + +| No. | Test Functions and Tools | Abbreviation | Test Case Scenario Creation | Test Case Validation | Purpose | Subsystem and Subsystem Pairing and Open Interfaces Interoperability Testing | E2E System Test | +|-----|------------------------------|--------------------------------|-----------------------------|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------|-----------------| +| | | | | | Protocol (PTP) Grand Master. | | | +| 25 | Test Controller / Automation | Test Controller and Automation | Yes | Yes | Used for testing orchestration and automation which includes test cases selection, scheduling, configuration of the DUT, SUT, Test functions and Tools in accordance to the selected test cases and test conditions. Test tool steps through the procedures of the test cases based on the current status and conditions of the test cases execution. Test results are analyzed and reported after the execution of the test cases. | Yes | Yes | + +1 + +2 + +3 + +Figure C-1 shows an example with the wrap around testing setup for E2E System under Test (SUT) with the Test functions and tools abbreviations updated. + +![Figure C-1: Wrap around testing setup for E2E System under Test (SUT) with Test Functions/Tools Abbreviations updated. The diagram illustrates a complex network architecture for testing. At the top, 'Test Equipment (Test or Emulated)' includes 'UE (Test UE or M-UE Emu)', 'Applications (App Test Svr or Traffic Gen)', and 'Core network (Test Core or Core Emu)'. Below this is the 'E2E System under Test' (SUT), which is divided into 'Subsystem under Test' and 'Interface under Test'. The SUT includes 'SMO', 'Non-Real Time RIC', 'Near-Real Time RIC', 'O-Cloud', 'xApps', 'O-DU [NR]', 'O-CU-CP, O-CU-UP [NR]', 'O-RU [NR]', 'FHM (Optional)', 'O-DU [LTE]', 'CU [LTE]', and 'O-eNB'. Interfaces are labeled with abbreviations like 'WG4 M-Plane (Hybrid) / O1', 'OFH1', 'OFH2', 'O1', 'A1', 'E2', 'F1', 'X2, Xn', 'E2', 'O1', 'W1'. A legend on the right indicates 'Test Equipment', 'E2E System under Test', 'Subsystem under Test', 'Interface under Test', and 'Not in scope in this version of the specification'. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'.](8581f33c1999a1354e8873775b162d59_img.jpg) + +Figure C-1: Wrap around testing setup for E2E System under Test (SUT) with Test Functions/Tools Abbreviations updated. The diagram illustrates a complex network architecture for testing. At the top, 'Test Equipment (Test or Emulated)' includes 'UE (Test UE or M-UE Emu)', 'Applications (App Test Svr or Traffic Gen)', and 'Core network (Test Core or Core Emu)'. Below this is the 'E2E System under Test' (SUT), which is divided into 'Subsystem under Test' and 'Interface under Test'. The SUT includes 'SMO', 'Non-Real Time RIC', 'Near-Real Time RIC', 'O-Cloud', 'xApps', 'O-DU [NR]', 'O-CU-CP, O-CU-UP [NR]', 'O-RU [NR]', 'FHM (Optional)', 'O-DU [LTE]', 'CU [LTE]', and 'O-eNB'. Interfaces are labeled with abbreviations like 'WG4 M-Plane (Hybrid) / O1', 'OFH1', 'OFH2', 'O1', 'A1', 'E2', 'F1', 'X2, Xn', 'E2', 'O1', 'W1'. A legend on the right indicates 'Test Equipment', 'E2E System under Test', 'Subsystem under Test', 'Interface under Test', and 'Not in scope in this version of the specification'. A note at the bottom states: 'The circles at both ends of each line indicates the endpoints of each interface'. + +4 + +5 + +6 + +**Figure C-1: Wrap around testing setup for E2E System under Test (SUT) with Test Functions/Tools Abbreviations updated** + +# Annex D: References to O-RAN WG6 Cloud Deployment Scenarios + +Annex D shows additional Cloud Deployment Scenarios from [4] for NR Standalone (SA) operation in Figures D-1 to D-7 and NR Non-Standalone (NSA) operation in Figures D-8 to D-11. Refer to [4] for up-to-date information and details on the Cloud Deployment Scenarios. + +The O-CU and vO-CU referred in [4] should be considered as O-CU CP/UP and vO-CU CP/UP, respectively. + +![Figure D-1: Cloud Deployment Scenario A for SA operation [4]. This diagram shows a single cloud environment labeled 'Edge cloud' containing a 'Near-RT RIC' and a 'vO-CU' block. The vO-CU is connected to a 'vO-DU' block via an F1 interface. The vO-CU also connects to a 'UPF, MEC' block. The vO-DU connects to an 'O-RU (/RU)' block via an 'Open fronthaul' interface, which includes an optional 'GW (Opt)'. The ratio between the vO-DU and O-RU is 1:N. The entire cloud environment is labeled 'Open chassis and blade spec'.](70067f1c59305d0a4616a1c44345c3a1_img.jpg) + +Figure D-1: Cloud Deployment Scenario A for SA operation [4]. This diagram shows a single cloud environment labeled 'Edge cloud' containing a 'Near-RT RIC' and a 'vO-CU' block. The vO-CU is connected to a 'vO-DU' block via an F1 interface. The vO-CU also connects to a 'UPF, MEC' block. The vO-DU connects to an 'O-RU (/RU)' block via an 'Open fronthaul' interface, which includes an optional 'GW (Opt)'. The ratio between the vO-DU and O-RU is 1:N. The entire cloud environment is labeled 'Open chassis and blade spec'. + +Figure D-1: Cloud Deployment Scenario A for SA operation [4] + +![Figure D-2: Cloud Deployment Scenario C for SA operation [4]. This diagram shows two cloud environments: 'Regional cloud' and 'Edge cloud'. The Regional cloud contains a 'Near-RT RIC' and a 'vO-CU' block. The vO-CU connects to a 'vO-DU' block in the Edge cloud via an F1c & F1-u interface. The vO-CU also connects to a 'UPF, MEC' block. The vO-DU connects to an 'O-RU (/RU)' block via an 'Open fronthaul' interface, which includes an optional 'GW (Opt)'. The ratio between the vO-DU and O-RU is 1:N. Both cloud environments are labeled 'Open chassis and blade spec'.](99c3e335244363bb828cfbe6b0be81e4_img.jpg) + +Figure D-2: Cloud Deployment Scenario C for SA operation [4]. This diagram shows two cloud environments: 'Regional cloud' and 'Edge cloud'. The Regional cloud contains a 'Near-RT RIC' and a 'vO-CU' block. The vO-CU connects to a 'vO-DU' block in the Edge cloud via an F1c & F1-u interface. The vO-CU also connects to a 'UPF, MEC' block. The vO-DU connects to an 'O-RU (/RU)' block via an 'Open fronthaul' interface, which includes an optional 'GW (Opt)'. The ratio between the vO-DU and O-RU is 1:N. Both cloud environments are labeled 'Open chassis and blade spec'. + +Figure D-2: Cloud Deployment Scenario C for SA operation [4] + +![Figure D-3: Cloud Deployment Scenario C.1 for SA operation [4]. This diagram shows two cloud environments: 'Regional cloud' and 'Edge cloud'. The Regional cloud contains a 'Near-RT RIC', a 'vO-CU-CP' block, and a 'vO-CU-UP1' block. The vO-CU-CP connects to the vO-CU-UP1 via an E1 interface. The vO-CU-UP1 connects to a 'vO-DU' block in the Edge cloud via an F1-u interface. The vO-CU-CP also connects to a 'UPF, MEC for #1' block. The vO-DU connects to an 'O-RU (/RU)' block via an 'Open fronthaul' interface, which includes an optional 'GW (Opt)'. The ratio between the vO-DU and O-RU is 1:N. Both cloud environments are labeled 'Open chassis and blade spec'.](2bb5e11ae9becc0673a1c2d4ee74b34d_img.jpg) + +Figure D-3: Cloud Deployment Scenario C.1 for SA operation [4]. This diagram shows two cloud environments: 'Regional cloud' and 'Edge cloud'. The Regional cloud contains a 'Near-RT RIC', a 'vO-CU-CP' block, and a 'vO-CU-UP1' block. The vO-CU-CP connects to the vO-CU-UP1 via an E1 interface. The vO-CU-UP1 connects to a 'vO-DU' block in the Edge cloud via an F1-u interface. The vO-CU-CP also connects to a 'UPF, MEC for #1' block. The vO-DU connects to an 'O-RU (/RU)' block via an 'Open fronthaul' interface, which includes an optional 'GW (Opt)'. The ratio between the vO-DU and O-RU is 1:N. Both cloud environments are labeled 'Open chassis and blade spec'. + +Figure D-3: Cloud Deployment Scenario C.1 for SA operation [4] + +![Figure D-4: Cloud Deployment Scenario C.2 for SA operation [4]. This diagram shows two cloud environments: 'Regional cloud' and 'Edge cloud'. The Regional cloud contains a 'Near-RT RIC' and a 'vO-CU1' block. The vO-CU1 connects to a 'vO-CU2' block in the Edge cloud via an F1 interface. The vO-CU1 also connects to a 'UPF, MEC for #1' block. The vO-CU2 connects to a 'vO-DU1' and 'vO-DU2' block in the Edge cloud via an F1 interface. The vO-DU1 and vO-DU2 connect to an 'O-RU (/RU)' block via an 'Open fronthaul' interface, which includes an optional 'GW (Opt)'. The ratio between the vO-DU1/vO-DU2 and O-RU is 1:N. Both cloud environments are labeled 'Open chassis and blade spec'.](e3ec9fecd9eb830cea91602ce61df3c0_img.jpg) + +Figure D-4: Cloud Deployment Scenario C.2 for SA operation [4]. This diagram shows two cloud environments: 'Regional cloud' and 'Edge cloud'. The Regional cloud contains a 'Near-RT RIC' and a 'vO-CU1' block. The vO-CU1 connects to a 'vO-CU2' block in the Edge cloud via an F1 interface. The vO-CU1 also connects to a 'UPF, MEC for #1' block. The vO-CU2 connects to a 'vO-DU1' and 'vO-DU2' block in the Edge cloud via an F1 interface. The vO-DU1 and vO-DU2 connect to an 'O-RU (/RU)' block via an 'Open fronthaul' interface, which includes an optional 'GW (Opt)'. The ratio between the vO-DU1/vO-DU2 and O-RU is 1:N. Both cloud environments are labeled 'Open chassis and blade spec'. + +Figure D-4: Cloud Deployment Scenario C.2 for SA operation [4] + +![Figure D-5: Cloud Deployment Scenario D for SA operation [4]. This diagram shows a three-tier architecture. On the left, a 'Regional cloud' contains a 'Near-RT RIC' and a 'vO-CU' block, both sitting on a 'Cloud Platform'. A 'UPF, MEC' block is connected to the vO-CU. The vO-CU connects to a 'Non virtualized O-DU' block in the 'Edge location' via an 'F1' interface. The O-DU connects to an 'O-RU (/RU)' block in the 'Cell site' via an 'Open fronthaul' interface. A dashed 'E2' interface connects the Near-RT RIC to the O-DU. A dashed 'E2' interface also connects the Near-RT RIC to the O-RU. A 'GW (Opt)' block is shown between the O-DU and O-RU. Ratios '1:M' and '1:N' are indicated above the E2 interfaces.](803c8101f8d02d7c41769b64b2d0e62a_img.jpg) + +Figure D-5: Cloud Deployment Scenario D for SA operation [4]. This diagram shows a three-tier architecture. On the left, a 'Regional cloud' contains a 'Near-RT RIC' and a 'vO-CU' block, both sitting on a 'Cloud Platform'. A 'UPF, MEC' block is connected to the vO-CU. The vO-CU connects to a 'Non virtualized O-DU' block in the 'Edge location' via an 'F1' interface. The O-DU connects to an 'O-RU (/RU)' block in the 'Cell site' via an 'Open fronthaul' interface. A dashed 'E2' interface connects the Near-RT RIC to the O-DU. A dashed 'E2' interface also connects the Near-RT RIC to the O-RU. A 'GW (Opt)' block is shown between the O-DU and O-RU. Ratios '1:M' and '1:N' are indicated above the E2 interfaces. + +Figure D-5: Cloud Deployment Scenario D for SA operation [4] + +![Figure D-6: Cloud Deployment Scenario E for SA operation [4]. This diagram shows a two-tier architecture. On the left, a 'Regional cloud' contains a 'Near-RT RIC' and a 'vO-CU' block, both sitting on a 'Cloud Platform'. A 'UPF, MEC' block is connected to the vO-CU. The vO-CU connects to a 'vO-DU' block in the 'Cell site' via an 'F1' interface. The vO-DU connects to a 'vO-RU' block in the 'Cell site' via an 'Open fronthaul' interface. A dashed 'E2' interface connects the Near-RT RIC to the vO-DU. A dashed 'E2' interface also connects the Near-RT RIC to the vO-RU. A 'GW (Opt)' block is shown between the vO-DU and vO-RU. Ratios '1:M' and '1:N' are indicated above the E2 interfaces.](18ff94108cfd32923ac3f51474673bbd_img.jpg) + +Figure D-6: Cloud Deployment Scenario E for SA operation [4]. This diagram shows a two-tier architecture. On the left, a 'Regional cloud' contains a 'Near-RT RIC' and a 'vO-CU' block, both sitting on a 'Cloud Platform'. A 'UPF, MEC' block is connected to the vO-CU. The vO-CU connects to a 'vO-DU' block in the 'Cell site' via an 'F1' interface. The vO-DU connects to a 'vO-RU' block in the 'Cell site' via an 'Open fronthaul' interface. A dashed 'E2' interface connects the Near-RT RIC to the vO-DU. A dashed 'E2' interface also connects the Near-RT RIC to the vO-RU. A 'GW (Opt)' block is shown between the vO-DU and vO-RU. Ratios '1:M' and '1:N' are indicated above the E2 interfaces. + +Figure D-6: Cloud Deployment Scenario E for SA operation [4] + +![Figure D-7: Cloud Deployment Scenario F for SA operation [4]. This diagram shows a three-tier architecture. On the left, a 'Regional cloud' contains a 'Near-RT RIC' and a 'vO-CU' block, both sitting on a 'Cloud Platform'. A 'UPF, MEC' block is connected to the vO-CU. The vO-CU connects to a 'vO-DU' block in the 'Edge cloud' via an 'F1' interface. The vO-DU connects to a 'vO-RU' block in the 'Cell site' via an 'Open fronthaul' interface. A dashed 'E2' interface connects the Near-RT RIC to the vO-DU. A dashed 'E2' interface also connects the Near-RT RIC to the vO-RU. A 'GW (Opt)' block is shown between the vO-DU and vO-RU. Ratios '1:M' and '1:N' are indicated above the E2 interfaces.](95874aa51378beec8a9cbfce6506d59c_img.jpg) + +Figure D-7: Cloud Deployment Scenario F for SA operation [4]. This diagram shows a three-tier architecture. On the left, a 'Regional cloud' contains a 'Near-RT RIC' and a 'vO-CU' block, both sitting on a 'Cloud Platform'. A 'UPF, MEC' block is connected to the vO-CU. The vO-CU connects to a 'vO-DU' block in the 'Edge cloud' via an 'F1' interface. The vO-DU connects to a 'vO-RU' block in the 'Cell site' via an 'Open fronthaul' interface. A dashed 'E2' interface connects the Near-RT RIC to the vO-DU. A dashed 'E2' interface also connects the Near-RT RIC to the vO-RU. A 'GW (Opt)' block is shown between the vO-DU and vO-RU. Ratios '1:M' and '1:N' are indicated above the E2 interfaces. + +Figure D-7: Cloud Deployment Scenario F for SA operation [4] + +![Figure D-8: Cloud Deployment Scenario A for NSA operation [4]. This diagram shows a three-tier architecture. On the left, an 'Edge cloud' contains a 'Near-RT RIC' and two 'vO-CU' blocks (vO-CU_n and vO-CU_e) sitting on a 'Cloud Platform'. A dashed 'E2' interface connects the Near-RT RIC to the vO-CU_n block. A dashed 'E2' interface also connects the Near-RT RIC to the vO-CU_e block. The vO-CU_n block connects to a 'vO-DU_n' block in the 'Cell site' via an 'F1' interface. The vO-CU_e block connects to a 'vO-DU_e' block in the 'Cell site' via an 'F1' interface. The vO-DU_n block connects to an 'O-RU_n (/RU_n)' block in the 'Cell site' via an 'Open fronthaul' interface. The vO-DU_e block connects to an 'O-RU_e (/RU_e)' block in the 'Cell site' via an 'Open fronthaul' interface. A dashed 'E2' interface connects the Near-RT RIC to the O-RU_n block. A dashed 'E2' interface also connects the Near-RT RIC to the O-RU_e block. A 'GW (Opt)' block is shown between the vO-DU_n and O-RU_n blocks. A 'GW (Opt)' block is also shown between the vO-DU_e and O-RU_e blocks. Ratios '1:M' and '1:N' are indicated above the E2 interfaces. A note at the bottom states: '(*) Pending 3GPP work completion on W1'.](f1ab6dab782d6f357c8a476c8e1c6c44_img.jpg) + +Figure D-8: Cloud Deployment Scenario A for NSA operation [4]. This diagram shows a three-tier architecture. On the left, an 'Edge cloud' contains a 'Near-RT RIC' and two 'vO-CU' blocks (vO-CU\_n and vO-CU\_e) sitting on a 'Cloud Platform'. A dashed 'E2' interface connects the Near-RT RIC to the vO-CU\_n block. A dashed 'E2' interface also connects the Near-RT RIC to the vO-CU\_e block. The vO-CU\_n block connects to a 'vO-DU\_n' block in the 'Cell site' via an 'F1' interface. The vO-CU\_e block connects to a 'vO-DU\_e' block in the 'Cell site' via an 'F1' interface. The vO-DU\_n block connects to an 'O-RU\_n (/RU\_n)' block in the 'Cell site' via an 'Open fronthaul' interface. The vO-DU\_e block connects to an 'O-RU\_e (/RU\_e)' block in the 'Cell site' via an 'Open fronthaul' interface. A dashed 'E2' interface connects the Near-RT RIC to the O-RU\_n block. A dashed 'E2' interface also connects the Near-RT RIC to the O-RU\_e block. A 'GW (Opt)' block is shown between the vO-DU\_n and O-RU\_n blocks. A 'GW (Opt)' block is also shown between the vO-DU\_e and O-RU\_e blocks. Ratios '1:M' and '1:N' are indicated above the E2 interfaces. A note at the bottom states: '(\*) Pending 3GPP work completion on W1'. + +Figure D-8: Cloud Deployment Scenario A for NSA operation [4] + +![Figure D-9: Cloud Deployment Scenario C for NSA operation [4]. This diagram shows a three-tier architecture. On the left, a 'Regional cloud' contains a 'Near-RT RIC' and two 'vO-CU' blocks (vO-CU_n and vO-CU_e) sitting on a 'Cloud Platform'. A dashed 'E2' interface connects the Near-RT RIC to the vO-CU_n block. A dashed 'E2' interface also connects the Near-RT RIC to the vO-CU_e block. The vO-CU_n block connects to a 'vO-DU_n' block in the 'Edge cloud' via an 'F1' interface. The vO-CU_e block connects to a 'vO-DU_e' block in the 'Edge cloud' via an 'F1' interface. The vO-DU_n block connects to an 'O-RU_n (/RU_n)' block in the 'Cell site' via an 'Open fronthaul' interface. The vO-DU_e block connects to an 'O-RU_e (/RU_e)' block in the 'Cell site' via an 'Open fronthaul' interface. A dashed 'E2' interface connects the Near-RT RIC to the O-RU_n block. A dashed 'E2' interface also connects the Near-RT RIC to the O-RU_e block. A 'GW (Opt)' block is shown between the vO-DU_n and O-RU_n blocks. A 'GW (Opt)' block is also shown between the vO-DU_e and O-RU_e blocks. Ratios '1:M' and '1:N' are indicated above the E2 interfaces. A note at the bottom states: '(*) Pending 3GPP work completion on W1'.](336d4382018733a9932bef307cc8d6db_img.jpg) + +Figure D-9: Cloud Deployment Scenario C for NSA operation [4]. This diagram shows a three-tier architecture. On the left, a 'Regional cloud' contains a 'Near-RT RIC' and two 'vO-CU' blocks (vO-CU\_n and vO-CU\_e) sitting on a 'Cloud Platform'. A dashed 'E2' interface connects the Near-RT RIC to the vO-CU\_n block. A dashed 'E2' interface also connects the Near-RT RIC to the vO-CU\_e block. The vO-CU\_n block connects to a 'vO-DU\_n' block in the 'Edge cloud' via an 'F1' interface. The vO-CU\_e block connects to a 'vO-DU\_e' block in the 'Edge cloud' via an 'F1' interface. The vO-DU\_n block connects to an 'O-RU\_n (/RU\_n)' block in the 'Cell site' via an 'Open fronthaul' interface. The vO-DU\_e block connects to an 'O-RU\_e (/RU\_e)' block in the 'Cell site' via an 'Open fronthaul' interface. A dashed 'E2' interface connects the Near-RT RIC to the O-RU\_n block. A dashed 'E2' interface also connects the Near-RT RIC to the O-RU\_e block. A 'GW (Opt)' block is shown between the vO-DU\_n and O-RU\_n blocks. A 'GW (Opt)' block is also shown between the vO-DU\_e and O-RU\_e blocks. Ratios '1:M' and '1:N' are indicated above the E2 interfaces. A note at the bottom states: '(\*) Pending 3GPP work completion on W1'. + +Figure D-9: Cloud Deployment Scenario C for NSA operation [4] + +![Figure D-10: Cloud Deployment Scenario C.2 for NSA operation. This diagram shows a three-tier architecture. On the left, the 'Regional cloud' contains a 'Near-RT RIC' and two 'vO-CU' blocks (vO-CU_N and vO-CU_E) connected via X2/Xn interfaces. In the center, the 'Edge cloud' contains two 'vO-CU' blocks (vO-CU_N and vO-CU_E) connected via F1 and W1(*) interfaces. On the right, the 'Cell site' contains 'O-RU' blocks (O-RU_N and O-RU_E) connected via 'Open fronthaul' interfaces, with optional 'GW' blocks. Ratios 1:M, 1:N, and 1:N are indicated at the top.](c9579d02c740bb5b962a9a6c2f294b81_img.jpg) + +Figure D-10: Cloud Deployment Scenario C.2 for NSA operation. This diagram shows a three-tier architecture. On the left, the 'Regional cloud' contains a 'Near-RT RIC' and two 'vO-CU' blocks (vO-CU\_N and vO-CU\_E) connected via X2/Xn interfaces. In the center, the 'Edge cloud' contains two 'vO-CU' blocks (vO-CU\_N and vO-CU\_E) connected via F1 and W1(\*) interfaces. On the right, the 'Cell site' contains 'O-RU' blocks (O-RU\_N and O-RU\_E) connected via 'Open fronthaul' interfaces, with optional 'GW' blocks. Ratios 1:M, 1:N, and 1:N are indicated at the top. + +Figure D-10: Cloud Deployment Scenario C.2 for NSA operation [4] + +![Figure D-11: Cloud Deployment Scenario D for NSA operation. This diagram shows a three-tier architecture. On the left, the 'Regional cloud' contains a 'Near-RT RIC' and two 'vO-CU' blocks (vO-CU_N and vO-CU_E) connected via X2/Xn interfaces. In the center, the 'Edge location' contains two 'Non virtualized O-DU' blocks (O-DU_N and O-DU_E) connected via F1 and W1(*) interfaces. On the right, the 'Cell site' contains 'O-RU' blocks (O-RU_N and O-RU_E) connected via 'Open fronthaul' interfaces, with optional 'GW' blocks. Ratios 1:M, 1:N, and 1:N are indicated at the top. A note at the bottom right states: (*) Pending 3GPP work completion on W1.](28262e4c1f42c1f16c8d8da339e79bad_img.jpg) + +Figure D-11: Cloud Deployment Scenario D for NSA operation. This diagram shows a three-tier architecture. On the left, the 'Regional cloud' contains a 'Near-RT RIC' and two 'vO-CU' blocks (vO-CU\_N and vO-CU\_E) connected via X2/Xn interfaces. In the center, the 'Edge location' contains two 'Non virtualized O-DU' blocks (O-DU\_N and O-DU\_E) connected via F1 and W1(\*) interfaces. On the right, the 'Cell site' contains 'O-RU' blocks (O-RU\_N and O-RU\_E) connected via 'Open fronthaul' interfaces, with optional 'GW' blocks. Ratios 1:M, 1:N, and 1:N are indicated at the top. A note at the bottom right states: (\*) Pending 3GPP work completion on W1. + +Figure D-11: Cloud Deployment Scenario D for NSA operation [4] + +# Annex ZZZ: O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant + +to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of O-RAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY + +OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED “AS IS” WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance’s sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity’s or association’s agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates’ performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. + +Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties’ or third party beneficiary’s right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full force and effect. \ No newline at end of file diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/085b0051ef7a701c6428b2041daf233c_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/085b0051ef7a701c6428b2041daf233c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e040a40dba115b90b9d54816162185d510e58911 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/085b0051ef7a701c6428b2041daf233c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a5363c279b7f845e26fc1d9e20b08e247d35d78e792e2f3313015688f82016b0 +size 62928 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/0b903a221c9442cb1cb810d626e28111_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/0b903a221c9442cb1cb810d626e28111_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7d424e714e76d1eb123e355e08a675bc439d8485 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/0b903a221c9442cb1cb810d626e28111_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1f59e5d5730e83928503f2a669793874d11c0ed8632f0ebff5edfefb00f34723 +size 32807 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/0eccdd3adf669f870d659316cec91da8_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/0eccdd3adf669f870d659316cec91da8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ccf06e41ef88c9bced8189f11ae44b59ca88cb8b --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/0eccdd3adf669f870d659316cec91da8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:96e9d984d98701f8141c774858b90257caa6b999c2f26ae3d85565bbf34a44c0 +size 25885 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/2f55686c1cfcb3465ce46debce0822a8_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/2f55686c1cfcb3465ce46debce0822a8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e6ec82463069913d94dd0582e13ef9aaf7c63dbc --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/2f55686c1cfcb3465ce46debce0822a8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9804d458d0df3a25c57d193b1ada8c10933041343b101cedb8e61f9ed150e43 +size 33688 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/31d37d25a61c69b969b81b68aa293bd0_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/31d37d25a61c69b969b81b68aa293bd0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f7af47856a1e106a55f662bcde2f9468141648be --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/31d37d25a61c69b969b81b68aa293bd0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dc856e9b08a5c16a61a9a6ee5ef588ef55eaea9cb60273dda778f3a51e240e90 +size 13865 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/551e35d264492786d0d610557ccc1b55_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/551e35d264492786d0d610557ccc1b55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eca96f14eff173ab5ead5b4ef80ff5827e92c33d --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/551e35d264492786d0d610557ccc1b55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8bb0af2dd788e055159db7a05c0b9285e7d655c861421ac8dc37e4b94c3b343 +size 4454 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/568ae4aa06916d9a53d78193fcf540e7_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/568ae4aa06916d9a53d78193fcf540e7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3f61a537de1c96a2cc747d7877c5ad4ca86d6e0b --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/568ae4aa06916d9a53d78193fcf540e7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2386eca21e7889ed19872f099ea921269d09d7d91b73b4f8ea5dbb82435b2b48 +size 153074 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/572c6760222830131acd0f5d2f096b87_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/572c6760222830131acd0f5d2f096b87_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..72b00c739e47e71d9a7a3a95d866ce12f10c242a --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/572c6760222830131acd0f5d2f096b87_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54b7ade948092a13664f49563044514fb5d483cb0ae2fe0b7e0b8dc3ec1f688c +size 51760 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/61320fbaf368680e25eb1cbd4097f2e4_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/61320fbaf368680e25eb1cbd4097f2e4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0749faf6ad52fda6cc4b79ad5936d7f3f0a43a76 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/61320fbaf368680e25eb1cbd4097f2e4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b7f75ccf4094b48348b316043a9701ba4bce030e6059ea02dff6ba2c40c8cd51 +size 25323 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/82e2284adc899d46d1cc481b9a8c5d9e_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/82e2284adc899d46d1cc481b9a8c5d9e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0342010e18821936c147826771519f1412189c2b --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/82e2284adc899d46d1cc481b9a8c5d9e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b8dbb5f23add3ea9c56267692246af923ce8a303edd72dc9aacbc75cc12afe58 +size 71923 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/83c8021ecb72f2b421ed610410494784_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/83c8021ecb72f2b421ed610410494784_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..21bc335dfae2c0d7aab6ccca9cd32f5622bbea53 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/83c8021ecb72f2b421ed610410494784_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:479f7d9f9388acea00be7cdff9bfb9fab4963ec8804287b30576bcf74af73813 +size 19129 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/94c4d9fdf1db430f6d83cb5ce9174f8c_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/94c4d9fdf1db430f6d83cb5ce9174f8c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c48aa2a67dadc4c37bdbd10aaa04ed930a9cba67 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/94c4d9fdf1db430f6d83cb5ce9174f8c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:012cb91f53b804fa02a7f4eeff0dbe6a02d3431e97d041a689b20cb265f5bee8 +size 63228 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/9556fe643c8a3cebd8e10274d9562bcc_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/9556fe643c8a3cebd8e10274d9562bcc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4244c3972fbb2d9a9650fb67bd92b947dc98f3c5 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/9556fe643c8a3cebd8e10274d9562bcc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1dfe9876f1922aceec4f32b96825429c76d8e8d78f4cd95d516309e05bb93863 +size 30592 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/99ce706f3b61380b69f40e7338f60238_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/99ce706f3b61380b69f40e7338f60238_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5919869c006b53491d782416e12f25900a5ee12e --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/99ce706f3b61380b69f40e7338f60238_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d92cf9832fda0671a8cf27c0a56751c9752cb231dd0f55a14e34db60cee64a3 +size 22467 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/a694aeeeea0de5a468ae2a2c8b136d00_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/a694aeeeea0de5a468ae2a2c8b136d00_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..229310aeef71173026e7eec684b1532d4e96360f --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/a694aeeeea0de5a468ae2a2c8b136d00_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7024aff2142fa9d92bb4077973ff67992486408081750dd5ea5666e642c588bb +size 47804 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/aa0c18a4505e15399667959fcd3c44e8_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/aa0c18a4505e15399667959fcd3c44e8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0c0d7786ff2965c8da0092e44ca1ec2602f6a24d --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/aa0c18a4505e15399667959fcd3c44e8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:594a18b39f7f29de77d4b8d6025486e58fd0ffa888aa7ce08d53bd7309d84d6e +size 54852 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/aba640f98aa56f0752bfca2d75afc98c_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/aba640f98aa56f0752bfca2d75afc98c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e794b3c70b8447327c88b2bf31b450b57a59224d --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/aba640f98aa56f0752bfca2d75afc98c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f6357814bce6ef25fe6b19ba157c87c0cf4564121763ca84ee074edf0c50b4bf +size 54067 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/ba1036b393a62afcbf27d9abf2d17312_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/ba1036b393a62afcbf27d9abf2d17312_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4868cff1e63a46602a578e7a567180783ec3188e --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/ba1036b393a62afcbf27d9abf2d17312_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cbd42bddd09ee5cc799e0ed61ac1cf9fad244fb6e06901dad290f40124e851d0 +size 91372 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7575c364a05dd515d7cf096c30ffc26f8ab2631 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b321cfff0a169d11fa6daa2e14ee4667e12bcfeff34e35ee9dd80b810a6385a6 +size 4491 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/cca81b7a324e9c34bd90e43e332a66b4_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/cca81b7a324e9c34bd90e43e332a66b4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c8015463ba5cf3eed4dfa3b6d310c76f9c56e1ae --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/cca81b7a324e9c34bd90e43e332a66b4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ae23156f0bcc92709a92f332da8b7de9a160967514ed5c1639996a6ff724f72c +size 23252 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/d18909a80d3f1827d2e08c41747b10ad_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/d18909a80d3f1827d2e08c41747b10ad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6da4e24e4a56c8e409eacdb4ed6c504b11b3c400 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/d18909a80d3f1827d2e08c41747b10ad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:69ae9ae86fd2857db251ffe0a3163d71a57b24805aaef4d2041758b986b751d1 +size 76545 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/dd7d08ae46512de8e8ec16fd9a8a893d_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/dd7d08ae46512de8e8ec16fd9a8a893d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8014d64661305e157efe81cf56f195fac71f0723 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/dd7d08ae46512de8e8ec16fd9a8a893d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:913add6179d5fcde9c275eb5214731ad49802eb4c50ad3712196e2626436705a +size 32683 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/df253b4d20dbb64896f22b2f1b3ddb0b_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/df253b4d20dbb64896f22b2f1b3ddb0b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ea8c9d1a86a145397bf0e64549afef1c0730a6f2 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/df253b4d20dbb64896f22b2f1b3ddb0b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd3c45cdaa4fdbcc0a43d4ef211157279535e83dabf1cbbca132eb220c4b2eaa +size 46593 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/e9b19bd9e1a1e5ae3e7f89383efdbccd_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/e9b19bd9e1a1e5ae3e7f89383efdbccd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..70ab5582715d81b10e4ec31854c1fdb6c5867728 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/e9b19bd9e1a1e5ae3e7f89383efdbccd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:af2f2719118c8859e64b74b5f23d3da705a1e522070602f52f26f7a74ba20789 +size 25964 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/ec5d4651d3468674c02d75ee19c26088_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/ec5d4651d3468674c02d75ee19c26088_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..af24e1dff23638f28006144508ffb0afe6b6e89c --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/ec5d4651d3468674c02d75ee19c26088_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:00713d08fd4d166421de44cf927c08e8b705f4a8dfeb62ed34394a0dccc93c14 +size 19427 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/f41528ff107609a04a7cc43aef419d17_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/f41528ff107609a04a7cc43aef419d17_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d83f431de20acbb98ddccaf7b7c516092039a45f --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/f41528ff107609a04a7cc43aef419d17_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cfc5bcbbaa060f77ee5271a73588677b0701ae9695c89cb3f0c88c40c7edf59a +size 123153 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/fa14b4e705b278d763fdb5c79f448d17_img.jpg b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/fa14b4e705b278d763fdb5c79f448d17_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..34ca2a737b3aca63ce9d36d510f67b59fbd70b7d --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/fa14b4e705b278d763fdb5c79f448d17_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:82347d6b89afb00912a8eb0a02c872dba4ae6206246e87efbdee56955668e043 +size 100786 diff --git a/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/raw.md b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..c9dad916b75efa1ca7c66fefa4e553d2a5535fd1 --- /dev/null +++ b/marked/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00/raw.md @@ -0,0 +1,1705 @@ + + +# --- **O-RAN Work Group 1 (Use Cases and Overall Architecture)****Communication and Computing Integrated Networks** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|---------------------------------------------------------------------------------------------------|----| +| Foreword ..... | 4 | +| Modal verbs terminology ..... | 4 | +| 1 Scope ..... | 5 | +| 2 References ..... | 5 | +| 2.1 Normative references ..... | 5 | +| 2.2 Informative references ..... | 5 | +| 3 Definition of terms, symbols and abbreviations ..... | 7 | +| 3.1 Terms ..... | 7 | +| 3.2 Symbols ..... | 7 | +| 3.3 Abbreviations ..... | 7 | +| 4 General Concept ..... | 7 | +| 4.1 The convergence of communication and computing in current industry landscape ..... | 7 | +| 4.1.1 Network Function Virtualization (NFV) in ETSI ..... | 8 | +| 4.1.2 Multi-Access Edge Computing (MEC) in ETSI ..... | 8 | +| 4.1.3 Edge Computing in 3GPP ..... | 8 | +| 4.1.4 Coordination of computing and networking in IMT-2020 and beyond in ITU-T ..... | 9 | +| 4.1.5 Computing aware traffic steering in IETF ..... | 9 | +| 4.2 Communication capabilities supported by O-RAN ..... | 10 | +| 4.3 Computing capabilities in O-RAN ..... | 10 | +| 4.4 The convergence of communication and computing in O-RAN ..... | 11 | +| 5 Scenarios and Use Cases ..... | 11 | +| 5.1 Use Case 1: Multi aspect handover optimization ..... | 11 | +| 5.1.1 Background Information ..... | 11 | +| 5.1.2 Motivation ..... | 12 | +| 5.1.3 Proposed Solution ..... | 13 | +| 5.1.4 Benefits of O-RAN Architecture ..... | 14 | +| 5.2 Use Case 2: Radio Edge Computing Resource Information Exposure ..... | 14 | +| 5.2.1 Background Information ..... | 14 | +| 5.2.2 Motivation ..... | 14 | +| 5.2.3 Proposed Solution ..... | 14 | +| 5.2.4 Benefits of O-RAN Architecture ..... | 16 | +| 5.3 Use Case 3: O-RAN and Mobile Devices collaborative AI/ML inference ..... | 16 | +| 5.3.1 Background Information ..... | 16 | +| 5.3.2 Motivation ..... | 18 | +| 5.3.3 Proposed Solution #1 ..... | 19 | +| 5.3.4 Proposed Solution #2 ..... | 20 | +| 5.3.5 Benefits of O-RAN Architecture ..... | 21 | +| 5.4 Use Case 4: XR rendering collaboration ..... | 22 | +| 5.4.1 Background Information ..... | 22 | +| 5.4.2 Motivation ..... | 23 | +| 5.4.3 Proposed Solution ..... | 24 | +| 5.4.4 Benefits of O-RAN Architecture ..... | 25 | +| 5.5 Use Case 5: Computing Resource Scheduling in V2X Communications ..... | 26 | +| 5.5.1 Background Information ..... | 26 | +| 5.5.2 Motivation ..... | 27 | +| 5.5.3 Proposed Solution ..... | 27 | +| 5.5.4 Benefits of O-RAN Architecture ..... | 28 | +| 5.6 Use case 6: Exposure of performance information to assist computing resource scheduling ..... | 28 | +| 5.6.1 Background Information ..... | 28 | + +| | | | +|---------|--------------------------------------------------------------------------------------|-----------| +| 5.6.2 | Motivation..... | 28 | +| 5.6.3 | Proposed Solution ..... | 29 | +| 5.6.3.1 | Performance information reporting triggers redeployment of a computing task ..... | 29 | +| 5.6.3.2 | Performance information reporting triggers to scale a computing task ..... | 33 | +| 5.6.4 | Benefits of O-RAN Architecture..... | 36 | +| 6 | Key Issues ..... | 36 | +| 6.1 | Key Issue #1: Joint Communication and Computing Optimization..... | 36 | +| 6.2 | Key Issue #2: O-RAN computing service provision..... | 36 | +| 6.3 | Key Issue #3: O-RAN integrated communication and computing service provision ..... | 37 | +| 6.4 | Key Issue #4: Edge application orchestration in O-RAN ..... | 37 | +| 7 | Potential Solutions ..... | 37 | +| 7.1 | Solution #1: O1 configurations for multi-aspect handover optimization..... | 37 | +| 7.1.1 | Key Issue Mapping ..... | 37 | +| 7.1.2 | Description ..... | 37 | +| 7.1.3 | Procedures..... | 38 | +| 7.1.4 | Impacts on entities, services and interfaces..... | 39 | +| 7.2 | Solution #2: Computing information exposure via Y1 interface ..... | 40 | +| 7.2.1 | Key Issue Mapping ..... | 40 | +| 7.2.2 | Description ..... | 40 | +| 7.2.3 | Procedures..... | 40 | +| 7.2.4 | Impacts on entities, services and interfaces..... | 41 | +| 7.3 | Solution #3: Computing Service Provisioning..... | 42 | +| 7.3.1 | Key Issue Mapping ..... | 42 | +| 7.3.2 | Description ..... | 42 | +| 7.3.3 | Procedures..... | 42 | +| 7.3.3.1 | Computing service registration and discovery..... | 42 | +| 7.3.3.2 | Computing service consumption ..... | 44 | +| 7.3.4 | Impacts on entities, services and interfaces..... | 45 | +| 7.4 | Solution #4: Integrated communication & computing service provisioning via SMO ..... | 45 | +| 7.4.1 | Key Issue Mapping ..... | 45 | +| 7.4.2 | Description ..... | 46 | +| 7.4.3 | Procedures..... | 46 | +| 7.4.4 | Impacts on entities, services and interfaces..... | 47 | +| 8 | Analysis on the Potential Architecture Impacts ..... | 48 | +| 9 | Deployment Scenarios..... | 49 | +| 9.1 | Scenario A: Local O-Cloud for private networks ..... | 49 | +| 9.2 | Scenario B: Device Edge Cloud and local O-Cloud for private networks ..... | 49 | +| 9.3 | Scenario C: O-Cloud coordination with global orchestrator..... | 50 | +| 10 | Potential Requirements ..... | 51 | +| 11 | Conclusion and Recommendations ..... | 51 | +| | Annex: Change history/Change request (history) ..... | 52 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document provides a technical report for integrated communication and computing in O-RAN. The use cases are studied and potential requirements are identified. + +--- + +# 2 References + +## 2.1 Normative references + +Not applicable. + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [i.2] Chih-Lin I, Guanding Yu, Shuangfeng Han, Geoffrey Ye Li, "Green and Software-defined Wireless Networks: From Theory to Practice", Cambridge University Press, 2019. +- [i.3] ETSI White Paper No. 54, Evolving NFV towards the next decade, May, 2023. +- [i.4] ETSI GS MEC 003: "Multi-access Edge Computing (MEC); Framework and Reference Architecture". +- [i.5] ITU-T Y.IMT2020-CNC-req, Recommendation, Requirements of coordination of computing and networking for IMT-2020 and beyond. +- [i.6] ITU-T Y.IMT2020-QoS-CNC-req, Recommendation, QoS assurance-related requirements and framework for coordination of computing and networking supported by IMT-2020 and beyond. +- [i.7] O-RAN TS: "O-RAN Architecture Description". +- [i.8] 3GPP TS 23.558: "Architecture for enabling Edge Applications". +- [i.9] 3GPP TS 23.501: "System architecture for the 5G System (5GS); Stage 2". +- [i.10] 3GPP TS 28.538: "Management and orchestration; Edge Computing Management (ECM)". +- [i.11] Draft-ietf-cats-usecases-requirements-00, Computing-Aware Traffic Steering (CATS) Problem Statement, Use Cases, and Requirements, July 2023. +- [i.12] 3GPP TR 26.928: "Extended Reality (XR) in 5G" +- [i.13] 3GPP TR 38.885: "Study on NR Vehicle-to-Everything (V2X)" +- [i.14] O-RAN TS: "Use Cases Detailed Specification". + +- [i.15] O-RAN TS: "Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN". +- [i.16] ITU-R, "Framework and overall objectives of the future development of imt for 2030 and beyond," Recommendation ITU, 2023. +- [i.17] X. Zhou et al., "A surface defect detection framework for glass bottle bottom using visual attention model and wavelet transform," IEEE Trans. Ind. Informat., vol. 16, no. 4, pp. 2189–2201, Apr. 2020. +- [i.18] J. Luo, Z. Yang, S. Li, and Y. Wu, "FPCB surface defect detection: A decoupled two-stage object detection framework," IEEE Trans. Instrum. Meas., vol. 70, pp. 1–11, 2021. +- [i.19] 3GPP TR 22.874: "Study on traffic characteristics and performance requirements for AI/ML model transfer in 5GS "," Dec. 2021. +- [i.20] N. Li, X. Li, Y. Yan, Q. Sun, Y. Han and K. Cheng, "Joint Communication and Computing Resource Optimization for Collaborative AI Inference in Mobile Networks," 2023 IEEE 98th Vehicular Technology Conference (VTC2023-Fall), Hong Kong, Hong Kong, 2023, pp. 1-5, doi: 10.1109/VTC2023-Fall60731.2023.10333702. +- [i.21] Gapeyenko M, Petrov V, Paris S, et al. Standardization of Extended Reality (XR) over 5G and 5G-Advanced 3GPP New Radio[J]. IEEE Network, 2023, 37(4): 22-28. +- [i.22] Huang Y, Li N, Sun Q, et al. Communication and Computing Integrated RAN: A New Paradigm Shift for Mobile Network[J]. IEEE Network, 2024. +- [i.23] 3GPP TR 38.838: "Study on XR (Extended Reality) Evaluations for NR (Release 17)". +- [i.24] 3GPP TR 22.261: "Service requirements for the 5G system; Stage 1". +- [i.25] 3GPP TR 26.928: "Extended Reality (XR) in 5G". +- [i.26] 3GPP TR 23.748: "Study on enhancement of support for Edge Computing in 5G Core network (5GC)". +- [i.27] 3GPP TR 23.758: "Study on application architecture for enabling Edge Applications". +- [i.28] 3GPP TS 23.558: "Architecture for enabling Edge Applications". +- [i.29] . +- [i.30] 3GPP TS 22.186: "Enhancement of 3GPP support for V2X scenarios", Mar. 2022. +- [i.31] O-RAN TS: "Non-RT RIC Architecture". +- [i.32] O-RAN TR: "SMO Intents-driven Management". +- [i.33] O-RAN TR: "Decoupled SMO Architecture". +- [i.34] O-RAN TS: "Operations and Maintenance Architecture". +- [i.35] ETSI GS NFV-IFA 011. Management and Orchestration; VNF Descriptor and Packaging Specification. +- [i.36] ETSI GS NFV-IFA 008. Management and Orchestration; Ve-Vnfm reference point -Interface and Information Model Specification. +- [i.37] O-RAN TS: "Y1 interface: Type Definitions". +- [i.38] O-RAN TS: "Y1 interface: General Aspects and Principles". +- [i.39] O-RAN TS: "O-Cloud Notification API Specification for Event Consumers". + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [i.1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [i.1]. + +| | | +|-------------|-------------------------------------------------| +| CCIN | Communication and Computing Integrated Networks | +| MEC | Multi-Access Edge Computing | +| NFV | Network Function Virtualization | +| Near-RT RIC | Near-Real-Time RAN Intelligent Controller | +| O-Cloud | O-RAN Cloud | +| O-CU-CP | O-RAN Central Unit – Control Plane. | +| O-CU-UP | O-RAN Central Unit – User Plane | +| O-DU | O-RAN Distributed Unit | +| XR | Extended Reality | + +# --- 4 General Concept + +## 4.1 The convergence of communication and computing in current industry landscape + +The past decades witnessed the convergence of communication and computing trends in mobile network. Great efforts were made and good momentum were achieved. C-RAN featured by centralization, cooperative, clean and cloud were first proposed in 2009, which depicts the vision of software based virtualized RAN [i.1]. The concept of Network Function Virtualization (NFV) was initiated from 2012. It introduced the information technology (IT) to enable the network transformation from the traditional physical hardware network into a new software based virtualized network [i.2]. This further steers up the pace for the convergence of communication and computing in RAN. Multiple-access edge computing (MEC), which enables compute-intensive applications for mobile devices and access to cloud computing service at the edge of communication networks, had attracted great attention [i.3]. The virtualized/cloudification RAN infrastructure can server as perfect edge computing platform. Thanks to the well-developed IT tools/frameworks, such as the containers, kubernetes, the general-purpose hardware infrastructure could be easily and dynamically shared by the RAN functionality and the edge applications, providing the converged capabilities of mobile communication and computing. Edge computing was also incorporated into 5G system in 3GPP since Release 15. However, the communication and computing services offered by the existing design, such as NFV and MEC, were designed separately and developed independently. To fulfill the gap, the coordination of computing and networking is proposed in the context of IMT-2020 and beyond, and provides network enhancements based on the functional + +architecture of IMT-2020, to achieve the computing and network joint optimization based on the awareness, control and management over computing resources [i.4] [i.5]. Besides the above, IETF initiated a new working group on computing aware traffic steering to study how the network edge can steer traffic between clients of a service and sites offering the services, considering the integrated network and compute resource status [i.10]. This chapter provides an overview of the related efforts in various standard developing organizations. + +### 4.1.1 Network Function Virtualization (NFV) in ETSI + +Network function virtualization is the one of the key pillars that accelerating the convergence of communication and computing in mobile networks. By adopting the cutting-edge IT technologies, the network functionalities are realized based on the general-purpose servers, which can be flexibly deployed on distributed cloud infrastructure. This revolutionized the way mobile communication networks are developed, deployed and operated. Series of NFV specifications are released by ETSI ISG NFV, from the concept, architecture, a set of interoperable implementation solutions, operational matters. Additional support for containerized VNFs and more cloud native deployment and automation are also specified in recent years. Regarding the further evolvement, the requirements from telecom service providers, including: 1) unified network management; 2) user of latest cloud-native IT, automation and Artificial Intelligence (AI) open source software; 3) multi-vendor interoperability and migration among different nodes, are being considered as the key drivers [i.3]. + +It is worth mentioning that the NFV work is more focusing on the network virtualization to offer the RAN services in IT manner with automation. It lays a good reference framework for RAN virtualization. But the dedicated requirements for RAN virtualization are not fully considered. This is further studied and specified in O-RAN. How computing services would be extended and how to provide the integrated communication and computing services based on the telecom cloud infrastructure for the both computing and communication intensive emerging services, such as metaverse, XR and AI, are not investigated. + +### 4.1.2 Multi-Access Edge Computing (MEC) in ETSI + +ETSI Industry Specifications Group (ISG) MEC defines the specifications relevant to the edge computing, where the specification is access agnostic and is not confined to mobile communications. ETSI ISG MEC specifies an open and standardized IT service environment that enables application to be deployed at the network edge close to edge user [i.4]. A common edge application enablement framework for multiple network technologies is developed with MEC service APIs. More specifically, network related service APIs are specified to provide added value to the edge application enabling the network aware service optimization. For example, radio network information (3GPP access), WLAN information, UE identity service APIs, V2X information service, etc., are specified. The MEC service APIs mostly focus on the how the MEC applications can be enabled and the orchestration and management of the MEC platform and the application. How the network would interact with the MEC functionalities and how the information required for network related service APIs can be obtained from the network is not fully investigated. To fill the gap, Y1 interfaces is introduced in O-RAN so that MEC can obtain the RAN analytics information via the Y1 interface [i.7]. However, the joint consideration of the edge service continuity and the communication service continuity, the unified orchestration and management of the mobile network and edge computing required for the operators are not yet investigated. + +In summary, MEC as another key pillar of the convergence of communication and computing, are now separately designed, deployed and operated on top of the mobile network. Thus, the dynamic coordination of the mobile network and application processing is not supported to ensure the end to end service QoS. + +### 4.1.3 Edge Computing in 3GPP + +3GPP edge computing work defines the 5G access specific interactions and interfaces as a complement part of the ETSI MEC work. The overall framework generally consists of five layers, i.e., application layer, edge enabler layer, edge hosting environment, edge management layer and 3GPP transport layer [i.8]. 3GPP develops specifications for the edge enabler layer, 3GPP transport layer, edge management layer, and some part of application layer (relevant to enabling of edge capabilities to the applications). + +In the transport layer, 5G supports to select/reselect user plane functions to steer/route traffic locally and connect to the local area data network in selected regions. It also supports Edge Application Server Discovery Function (EADSF), which enables the discovery of the IP address(es) of the EASs for the edge application [i.9]. + +Regarding the management layer, different business roles involved in edge computing and the mobile network, and their relationship are also discussed along with the edge computing management specification [i.10]. Generally, PLMN operator is responsible for the 3GPP transport layer and deployment of the 5G network functions, edge computing service provider (ECSP) is responsible for the deployment of edge data network that contain edge enabler client (EEC) in the UE and edge enabler server (EES), and application service provider (ASP) is responsible for the creation of edge application servers (EASs) and application clients (ACs). The management system framework for edge computing defined in 3GPP consists of the PLMN management system and the ECSP management system. The two systems can interact with ETSI Network Function Virtualization Management and Orchestration (MANO) to perform lifecycle management functions. + +The edge enabler layer provides edge capability related Application Programming Interfaces (APIs) for the application developers [i.8]. With the well-defined services and APIs, the application developers can locate and connect to the most suitable edge application server, and to explore the service optimization leveraging the potential network information provided by underlying 3GPP network. + +Similar to the MEC work in ETSI, the joint optimization of network and computing resources are not yet considered to guarantee the end-to-end service quality that depends on both the computing and communication process. + +### 4.1.4 Coordination of computing and networking in IMT-2020 and beyond in ITU-T + +The requirements, framework and QoS assurance related requirement and framework for the coordination of computing and networking in IMT-2020 and beyond are studied in ITU-T [i.5] [i.6]. The coordination of computing and networking is defined as the coordination of utilization, control and management of computing, storage and networking resources. It provides the capability to jointly schedule the computing, storage and networking resources, and is expected to enhance the QoS support for IMT-2020 networks and beyond. The coordination of computing and networking is envisioned for the resource layer, control layer, service layer, and management and orchestration layer. + +The general requirements identified in the draft recommendations [i.5] includes: awareness of networking, computing and storage resources; joint scheduling of resources; unified management of resources; AI/ML integration; unified standard interfaces for resources; support resource transaction services so that the resource users can order computing services; energy saving and security and privacy related requirements. + +The high level QoS assurance mechanisms investigated for the coordination of computing and networking in IMT-2020 and beyond in [i.6] includes: + +- Perception of computing and networking status +- Perception of service requirements +- Mapping among service, computing and network requirements +- Joint scheduling of computing and networking +- Unified management and orchestration of computing and networking + +### 4.1.5 Computing aware traffic steering in IETF + +IETF initiated computing aware traffic steering working group in Mar. 2023. The main motivation is to study how to integrate both network and compute conditions in the optimization function that informs the steering applied by the network edge nodes with the desire to operate that function on nodes within the service provider's network, logically separated from service operation. The main motivation is the performance experienced by clients will depend on both + +network metrics such as bandwidth and latency, and compute metrics such as processing, storage capabilities, and capacity. For some services, especially, the XR and autonomous vehicles assisted by the network, it is desired to optimize network edge node traffic steering based on the awareness of both the communication and computing related metrics. + +The use cases and requirements for the computing aware traffic steering are studied in [i.11]. Four typical use cases, namely, computing-aware AR/VR, computing-aware intelligent transportation, computing-aware digital twin and computing-aware SD-WAN are discussed considering a distributed computing scenario. The requirements to support computing aware traffic steering are also identified: + +- Support dynamic and effective selection among multiple service instances +- Support agreement on metric representation of both the compute capability related metrics and network metrics +- Support flexible use of network and computing metrics for service instance selection +- Support session and service continuity +- Preserve communication confidentiality. + +## 4.2 Communication capabilities supported by O-RAN + +O-RAN is committed to evolving radio access networks with its core principles being intelligence and openness. The overall O-RAN architecture is specified in [i.7], where the key elements including the service management and orchestration framework, O-RAN network functions and O-Cloud are described. In general, the O-RAN architecture supports the 4G and 5G RAN communication services. With the hierarchical RAN intelligent controllers, namely Non-RIC and Near-RT RIC introduced in O-RAN, various AI/ML empowered RAN optimization use cases are explored in [i.14], offering improved RAN performance, user experiences, network resource utilization efficiency and energy efficiency. + +## 4.3 Computing capabilities in O-RAN + +Diversified 5G services call for new level of agility in RAN deployment and scaling. RAN cloudification emerges as a promising solution and offers new innovation paradigm. O-RAN architecture adopts the RAN cloudification design. O-Cloud is defined as a cloud computing platform comprising a collection of physical infrastructure nodes that meet O-RAN requirements to host the relevant O-RAN NFs (i.e., Near-RT RIC, O-CU-CP, O-CU-UP, and O-DU) [i.7]. + +O-Cloud platform hardware includes compute, network and storage components and may also include hardware accelerators for improving the computing efficiency by offloading the most computation-intensive or timing-intensive tasks in the radio protocol stack. O-Cloud platform software consists of cloud platform runtime, cloud platform management and virtual machine (VM)/container management and orchestration. The cloud platform runtime includes the hypervisor/container runtime, accelerator driver, network driver and precision time protocol to host the RAN functions. The cloud platform management is responsible for the life cycle management, high availability, fault management and configuration of the cloud infrastructure. The VM/container management and orchestration is typically implemented with OpenStack for VM deployments and Kubernetes (K8s) for container deployment. The cloud architecture and deployments scenarios for O-RAN virtualized RAN are described in [i.15]. + +The cloudification in O-RAN greatly improves the RAN deployment flexibility, and transforms O-RAN into a native and cost-effective edge computing platform. Thus, edge application services can be deployed on the existing O-Cloud infrastructure along with the O-RAN functions. This lays the foundation of “beyond communication” service provision, offering the opportunities for RAN to provide the integrated communication and computing services. + +## 4.4 The convergence of communication and computing in O-RAN + +The CCIN is a network which could provide not only traditional RAN services such as connection and mobility control but also applications services by leveraging the communication and computing resources in an integrated manner. The goal of CCIN is to provide the beyond-connection services and bring new values to operators. A CCIN network has the following features. + +1. Sharable resources. Resources include not only the communication resources such as the radio bearers, the TTL, the frequency etc. but also those of computing resources including various hardware from CPU, GPU to switches, storage and so on. Thanks to the cloud technology, such resources could be scheduled and allocated for different usage, i.e. communication and computing on demand. For example, in the daytime, the computing power of the CPU should be used to process the radio stack for 5G coverage. While at night when the traffic volume drops, the CPU is then freed from the 5G computing and changed for AI model training. +2. Holistic orchestration of communication and computing resources. The resources of CCIN should be scheduled and orchestrated in a holistic way. The CCIN itself should be capable of scheduling and allocating the communication and computing resources for different workloads. In addition, the CCIN should also be able to expose such resources and status to external in collaboration with the other network functions, e.g. core networks. A global orchestrator should be aware of the resources, orchestrate them together with the functions and services in a holistic way to optimize the system performance, efficiency and/or user experience. +3. Integrated service provisioning. The CCIN could provide services externally and the services could be of different types. It could be in the very basic format of computing capability in the unit of Floating-point Operation Per Second (FLOP). It could be further provided in a more abstract yet user-sensible way. For example, the services could be the capability of training certain type of AI models with certain number of parameters. Eventually, such service provisioning would bring the beyond-connection value to operators. + +NOTE: If and how O-RAN addresses this topic of integrated service provisioning is for further study. + +In essence, CCIN features the integration of communication and computing. There could be several levels of integration. On the first level, the computing functions simply co-locate with the communication functions on the same hardware platform, i.e. the COTS servers. There is little interaction in between except that the user-plane local break-out by means of User-plane Function (UPF) could be implemented for local processing. On the second level, interaction between the communication and application services is enabled to provide RAN and application mutually aware optimization. On this level, the interaction is mainly via an established interface or Application Program Interface (API). For the third and the last level of integration in CCIN, the communication and computing relate to each other in a symbiotic way, i.e., they are jointly scheduled in a real-time way, managed and orchestrated in a holistic manner. With the orchestrator, the computing resources could be scaled in and out in a much more dynamic way with smaller granularity as the workload changes with the applications than the second level. + +# --- 5 Scenarios and Use Cases + +## 5.1 Use Case 1: Multi aspect handover optimization + +### 5.1.1 Background Information + +Communication and Computing Integrated Networks enables the collaboration of communication network and computing. It is an approach of softening the boundaries between the cloud computing and networking, such that their resources can be utilized in the most efficient way. This allows the applications to leverage on such convergence of compute and network resources. Cloud based RAN solutions can play an important role in the Communication and + +Computing Integrated Networks with its potential to share some of its vacant computing resources as the edge computing platform. New age applications based on XR (see 3GPP TR 26.928 [i.12], clause 4.1.1), V2X (see 3GPP TR 38.885 [i.13]) can benefit from Communication and Computing Integrated Networks but they require application mobility in addition to posing stringent requirements on both communication and computing. New network architecture for Communication and Computing Integrated Networks needs to address these application requirements. + +The types of computing resources required for different applications can be diverse based on the nature of the applications. However, the computing resources available in different entities might be of different computing resource type than what is required for specific applications. It is also possible that capabilities of a computing resource type required for specific applications is different even if an entity supports required computing resource type. Computing resource types referred here could be but not limited to the support for Graphical Processing Unit, Neural Processing Unit, Deep Processing Unit, etc. An example illustration of the cloud based joint RAN + Computing entity used in Communication and Computing Integrated Networks (CCIN) is given below in the Figure 5.1.1-1. + +![Figure 5.1.1-1: Example illustration of cloud based joint RAN + Computing entity. The diagram shows three mobile devices (represented by small squares) connected via radio waves to a central cloud entity. The cloud entity is labeled with 'O-CU' and 'O-DU' blocks. Below these, a dashed box contains 'apps' and 'MEC' blocks. At the bottom of the cloud, there are labels for 'NPU', 'DPU', 'GPU', and '...'. A callout box points to the dashed box with the text: 'Cloud Resources in a RAN deployment that could be shared with other computing applications'.](0eccdd3adf669f870d659316cec91da8_img.jpg) + +Figure 5.1.1-1: Example illustration of cloud based joint RAN + Computing entity. The diagram shows three mobile devices (represented by small squares) connected via radio waves to a central cloud entity. The cloud entity is labeled with 'O-CU' and 'O-DU' blocks. Below these, a dashed box contains 'apps' and 'MEC' blocks. At the bottom of the cloud, there are labels for 'NPU', 'DPU', 'GPU', and '...'. A callout box points to the dashed box with the text: 'Cloud Resources in a RAN deployment that could be shared with other computing applications'. + +**Figure 5.1.1-1: Example illustration of cloud based joint RAN + Computing entity.** + +### 5.1.2 Motivation + +In a Communication and Computing Integrated Networks, the idea is to use the vacant computing resources from the cloud-based RAN (e.g., if the network load is low), to perform some edge computing related tasks so that cloud resources are used efficiently. In particular, leveraging the proximity of the cloud-based RAN entities to the end users/devices is a key factor to address low latency requirements of the tasks/applications. But in order to take advantage of this opportunity the following needs to be considered: + +- If the vacant resources match the task requirements in terms of the type of the computing resource and related capabilities. +- If the amount of vacant resources of required type/capability suffices the task requirements +- If the nodes are within the proximity required to support the continuity of the service and service latency requirements of the applications. + +In the use case of UE handover especially in the scenario where the UE needs to run applications with high computing and low latency requirements such as XR based applications the above stated challenges are more prominent. Thus, in such use case it is desirable that system considers the aspects of computing capability and availability of cloud-based RAN entities while supporting the mobility of UE and applications in it. + +In particular, it is important to create the awareness in a cloud-based RAN entity of the information regarding the computing capability and availability of other cloud-based RAN entities in the proximity and use these multiple aspects as part of the UE handover decisions. Proximity here means that coverage area of the cells served by source cloud-based RAN entity has some overlap with the coverage area of the cells served by target cloud-based RAN entity. + +![Figure 5.1.2-1: Example illustration of multi aspect handover. The diagram shows four overlapping colored regions representing different cloud-based RAN entities: Yellow Node 3 (top-left), Green Node 4 (top-right), Pink Node 2 (bottom-right), and Blue Node 1 (bottom-center). Each node contains a cloud icon with a GPU symbol. A red square labeled 'XR' is positioned at the intersection of the Yellow, Green, and Blue nodes, with a red arrow pointing upwards towards the Green node, indicating a handover process.](99ce706f3b61380b69f40e7338f60238_img.jpg) + +Figure 5.1.2-1: Example illustration of multi aspect handover. The diagram shows four overlapping colored regions representing different cloud-based RAN entities: Yellow Node 3 (top-left), Green Node 4 (top-right), Pink Node 2 (bottom-right), and Blue Node 1 (bottom-center). Each node contains a cloud icon with a GPU symbol. A red square labeled 'XR' is positioned at the intersection of the Yellow, Green, and Blue nodes, with a red arrow pointing upwards towards the Green node, indicating a handover process. + +**Figure 5.1.2-1: Example illustration of multi aspect handover** + +### 5.1.3 Proposed Solution + +In order to address aforementioned use case and related challenges it is proposed extend the Communication and Computing Integrated Networks framework. Such extensions comprise introduction of proximal computing table which stores the information on the compute capabilities of cloud-based RAN entities and its usage in UE handover decisions. This helps the handover of the UE to a target cloud-based RAN entity in the proximity with computing resource types of relevant capabilities and availability required for the applications in that UE. The proximal computing table can be of following types: + +1. Proximal Computing Capability Table which is a neighbor relation table indicative of computing resource types and/or capability of compute resource types of the target cloud-based RAN entities in the proximity of the source cloud-based Radio entity. Examples for resource types referred here are GPU, NPU, DPU, AI accelerator, etc. Examples for the capability of resource types referred here are supported types of AI algorithms, supported number of Ray Tracing Cores, etc. +2. Proximal Computing Availability Table which is a neighbor relation table indicative of current availability of computing resource types of the target cloud-based RAN entities in the proximity of the source cloud-based RAN entity. This may comprise a predicted availability of the computing resource types for predetermined time periods. + +Proposed solution consists of rApp, SMO/Non-RT RIC Framework, Near-RT RIC, E2 nodes and O-Cloud. rApp retrieves CM data, PM data, location data of different cloud-based RAN entities and capability of computing resource types, load/availability of computing resource types in different cloud-based RAN entities. rApp derives Proximal Computing Capability Table for each cloud-based RAN entity based on the proximity analysis of different cloud-based RAN entities in the neighborhood and the capability analysis of computing resource types in different cloud-based RAN entities within the proximity. Proximity analysis uses different data including but not limited to PM data and location data. Similarly, rApp derives Proximal Computing Availability table for a cloud-based RAN entity based on the load/availability analysis of the computing resource types in different target entities in the corresponding Proximal Computing Capability table. rApp may rely on AI/ML model-based load/availability pattern analysis of the computing resource types, this includes prediction of available vacant resources at specific time window in a specific day e.g., during which time window it is expected to have the most vacant resources, with which confidence that can be determined and exposed etc. + +rApp creates different O1 based configurations including policies for multi-aspect handover optimization based on the Proximal Computing Capability Table and Availability Table at one or more near-RT RIC instances. Near-RT RIC will then use E2 control or E2 policy to ensure the UE handover to most optimum target cloud-based Radio entity. + +### 5.1.4 Benefits of O-RAN Architecture + +O-RAN architecture allows rApp based use cases to build intelligence based on both traditional RAN network data available over O1 interface as well as cloud-based computing capability data available over O2 interface. In addition, E2 control or E2 policies facilitates the finer control of UE level handover decisions in E2 nodes. In summary, O-RAN architecture provides necessary ingredients to facilitate multi aspect handover optimization. + +## 5.2 Use Case 2: Radio Edge Computing Resource Information Exposure + +### 5.2.1 Background Information + +AI/ML processing for network intelligence and automation evolution, as well as new 5G edge applications supporting e.g., immersive Virtual Reality (VR), autonomous driving, and intelligent internet of things (IoT), etc. put an unprecedented demand on the edge computing resources. The O-Cloud architecture of O-RAN and the spatial and temporal tidal effects of RAN communication services offer great opportunities for sharing underutilized computing resources in the RAN infrastructure. This helps to improve the resource utilization efficiency and reduce operators' investment on the edge computing infrastructure. + +### 5.2.2 Motivation + +The main objective is to provide radio edge computing resource information exposure service based on O-RAN architecture and its open interface. In O-RAN, SMO is a great candidate to provide radio edge computing resource information exposure service to the service consumers for perceiving unused computing resources in the O-Cloud infrastructure. The service consumers might be other orchestrators, e.g., central cloud orchestrator, edge cloud orchestrator, radio edge cloud orchestrator, device edge cloud orchestrator etc. The orchestrators could request computing resource information for multi-cloud collaboration, such as task migration between multiple clouds or edge intelligence. The service consumers could also be other 3rd applications, e.g., vertical customers, VR consumers etc., which could request computing resource information for application deployment using shared computing resources in a secured way. + +### 5.2.3 Proposed Solution + +Entities/resources involved in the use case: + +- 1) SMO: + - a) Support collect and analysis computing related resources from O-Cloud. + - b) Support provide radio edge computing resource information service, send the radio computing information for managed O-Cloud related computing resources to the service consumer, e.g., Orchestrator/Application Server. +- 2) O-Cloud: + - a) Support computing related inventory and updated resources report with required granularity to SMO over O2 interface. +- 3) Radio Edge Computing Resource Information Exposure Service Consumer: + - a) Request/subscribe radio edge computing resource information from SMO. + - b) The service consumer might be Orchestrator/Application Server. + +The whole procedure is presented in Table 5.2.3-1, illustrated by Figure. 5.2.3-1. + +**Table 5.2.3-1: Radio Edge Computing Resource Information Exposure** + +| Use Case Step | Description of the Step | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | Radio Edge Computing Resource Information Exposure | +| Actors and Roles | SMO, O-Cloud, orchestrator/application server | +| Assumptions |
  • - All relevant functions and components are instantiated.
  • - O2 interface connectivity is established with SMO.
| +| Pre-conditions |
  • - SMO and O-Cloud are instantiated with O2 interface connectivity being established between them.
Editor' s Note: Security related procedure is FFS. | +| Begins when | Orchestrators or application servers want to request/subscribe Radio Edge Computing Resource information. | +| Step 1 (M) | Orchestrators or application servers, e.g., RAN service computing center, send Radio Edge Computing Resource information request to SMO for initial or updated computing resource information. | +| Step 2 (M) | SMO requests or subscribes the measurement data from O-Cloud, and receives computing related resources information from O-Cloud through response or periodic notifications. | +| Step 3 (O) | Alternatively, SMO could use AI/ML or other methods to perform computing related resource data statistics and analysis. | +| Step 4 (M) | SMO send Radio Edge Computing Resource information response, including the RAN side computing related information managed by SMO. | +| Ends when | Orchestrators or application servers get the response. | +| Post Conditions | N/A | + +``` + +@startuml +Skin rose +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 + +Box "Service Consumer" #lightcyan + Participant "Orchestrator/Application Server" as app +End box +Box "Service Management and Orchestration" #gold + Participant "SMO" as smo +End box +Box "O-Cloud Platform" #lightseagreen + Participant ims as "IMS/DMS" +End box + +app -> smo : 1 Radio Edge Computing Resource Information Request +smo -> ims: 2.1 <> Data Collection Request/Subscribe +ims -> smo: 2.2 <> Data Collection Response/Notify +smo -> smo: 3 Data analysis +smo -> app: 4 Radio Edge Computing Resource Information Response +@enduml + +``` + +![Figure 5.2.3-1: Radio Edge Computing Resource Information Exposure. This diagram illustrates the interaction between three main components: Service Consumer, Service Management and Orchestration (SMO), and O-Cloud Platform. The Service Consumer (light blue box) contains two 'Orchestrator/Application Server' blocks. The SMO (yellow box) contains two 'SMO' blocks. The O-Cloud Platform (teal box) contains two 'IMS/DMS' blocks. The sequence of operations is: 1. A 'Radio Edge Computing Resource Information Request' is sent from the top Orchestrator/Application Server to the top SMO. 2.1. A '«O2» Data Collection Request/Subscribe' is sent from the top SMO to the top IMS/DMS. 2.2. A '«O2» Data Collection Response/Notify' is sent from the top IMS/DMS back to the top SMO. 3. 'Data analysis' is performed by the top SMO. 4. A 'Radio Edge Computing Resource Information Response' is sent from the top SMO back to the top Orchestrator/Application Server.](df253b4d20dbb64896f22b2f1b3ddb0b_img.jpg) + +Figure 5.2.3-1: Radio Edge Computing Resource Information Exposure. This diagram illustrates the interaction between three main components: Service Consumer, Service Management and Orchestration (SMO), and O-Cloud Platform. The Service Consumer (light blue box) contains two 'Orchestrator/Application Server' blocks. The SMO (yellow box) contains two 'SMO' blocks. The O-Cloud Platform (teal box) contains two 'IMS/DMS' blocks. The sequence of operations is: 1. A 'Radio Edge Computing Resource Information Request' is sent from the top Orchestrator/Application Server to the top SMO. 2.1. A '«O2» Data Collection Request/Subscribe' is sent from the top SMO to the top IMS/DMS. 2.2. A '«O2» Data Collection Response/Notify' is sent from the top IMS/DMS back to the top SMO. 3. 'Data analysis' is performed by the top SMO. 4. A 'Radio Edge Computing Resource Information Response' is sent from the top SMO back to the top Orchestrator/Application Server. + +**Figure 5.2.3-1: Radio Edge Computing Resource Information Exposure** + +Required data: + +Computing related resource data are expected to be retrieved by SMO from O-Cloud for radio computing related data statistics, analysis and information exposure, including total, allocated, reserved, and available: + +- 1) CPU number for O-Cloud, cluster, or node +- 2) vCPU number for O-Cloud, cluster, or node + +Exposed data: + +- 1) Radio Edge Computing Resource information exposed by SMO includes but is not limited to, +- 2) Total capacity of computing or number of computing resources +- 3) Allocated capacity of computing or number of computing resources +- 4) Reserved capacity of computing or number of computing resources +- 5) Available capacity of computing or number of computing resources +- 6) Other computing related information + - a) Computing resource identifier, e.g., Cloud identifier, Node identifier + - b) Computing resource location, + - c) vCPU number, etc. + +### 5.2.4 Benefits of O-RAN Architecture + +The proposed solution supports an effective way to expose the radio edge computing resource information to the service consumer, such as other orchestrators or applications. It requires features provided by the O-RAN architecture to collect the radio computing related data, alternatively supports statistics, analysis, and expose by SMO. + +## 5.3 Use Case 3: O-RAN and Mobile Devices collaborative AI/ML inference + +### 5.3.1 Background Information + +Integrated artificial intelligence (AI) and communication has been identified as crucial elements for IMT-2030 by ITU-R [i.16]. AI/ML-based applications are increasingly demanding in terms of computation, memory, and power consumption. However, mobile devices typically have limited energy, computing capability, and memory resources, making it challenging to run complete AI/ML inference. There is a growing need to offload AI/ML inference from + +mobile devices to the central cloud or edge computing platform to support the mobile AI/ML inference application through collaborative computing. + +For example, [i.17] and [i.18] give a manufacturing scenario that utilizes AI/ML technologies for analyzing image data in a product defect detection application. The product's image is initially captured by a sensor such as a camera and then it can be transmitted to the edge server equipped with an AI/ML model for identifying and classifying the potential defects in the product by analyzing the image data. Subsequently, the inference result is communicated to the console's actuator (e.g. a classifier), which directs the product to different processes based on the result. The AI/ML model can also be split between the mobile devices and the edge computing platform considering the radio transmission status and the mobile devices' computing capabilities. In several use cases of split AI/ML operation between AI/ML endpoints studied in 3GPP TR22.874 [i.19], the AI/ML endpoints at the end user side can be mobile devices, robotics, cameras, etc., and the AI/ML endpoints on the network side can be AI/ML edge servers, cloud servers, application servers, etc. When the performance of the AI/ML inference task decreases (e.g., the inference end-to-end latency increases and/or the inference accuracy decreases), service experience downgrades, or mobile device's computing capability cannot support current AI/ML inference computation, the AI/ML model split point between the AI/ML endpoints and the AI/ML exit point can be dynamically optimized by adjusting the computing workload of the AI/ML endpoints and the communication volume between AI/ML endpoints to ensure service quality. Taking ResNet18 as an example, Figure 5.3.1-1 shows the framework of the AI/ML model [i.20] and Table 5.3.1-1 shows data size of the intermediate outcomes and computation load for the split point inference of the ResNet18 model. The data size of AI/ML model intermediate outcomes need to be transmitted from mobile device to network side, computation load offloaded as well as the accuracy of the various AI/ML exit point are summarized in the following table. + +![Figure 5.3.1-1: The framework of the multi-branch ResNet-18 model. The diagram illustrates the architecture of a multi-branch ResNet-18 model. It starts with an 'Image' input, followed by a '7*7 conv, 64, /2' layer. The main path consists of several stages of '3*3 conv' layers with varying kernel sizes and stride 2. The first stage has two '3*3 conv, 64' layers. The second stage has two '3*3 conv, 128, /2' layers. The third stage has two '3*3 conv, 256, /2' layers. The fourth stage has two '3*3 conv, 512, /2' layers. The final stage is an 'avgpool' layer followed by an 'FC(512, 1000)' layer and a 'softmax' output. Three exit points are shown on the right: 'Exit 1' (after the first stage), 'Exit 2' (after the second stage), and 'Exit 3' (after the third stage). Each exit point has a corresponding 'conv' layer and an 'FC' layer.](aba640f98aa56f0752bfca2d75afc98c_img.jpg) + +Figure 5.3.1-1: The framework of the multi-branch ResNet-18 model. The diagram illustrates the architecture of a multi-branch ResNet-18 model. It starts with an 'Image' input, followed by a '7\*7 conv, 64, /2' layer. The main path consists of several stages of '3\*3 conv' layers with varying kernel sizes and stride 2. The first stage has two '3\*3 conv, 64' layers. The second stage has two '3\*3 conv, 128, /2' layers. The third stage has two '3\*3 conv, 256, /2' layers. The fourth stage has two '3\*3 conv, 512, /2' layers. The final stage is an 'avgpool' layer followed by an 'FC(512, 1000)' layer and a 'softmax' output. Three exit points are shown on the right: 'Exit 1' (after the first stage), 'Exit 2' (after the second stage), and 'Exit 3' (after the third stage). Each exit point has a corresponding 'conv' layer and an 'FC' layer. + +**Figure 5.3.1-1: The framework of the multi-branch ResNet-18 model** + +**Table 5.3.1-1 Data size and computation load of ResNet18** + +| Layer ID | Type | Data size (bit) | Computation load (FLOPs) | Accuracy of exit point | +|------------|----------|-----------------|--------------------------|------------------------| +| 1 | conv1 | 25690112 | 118013952 | | +| | maxpool | 6422528 | 7225344 | | +| 2 | conv2-1 | 6422528 | 115605504 | | +| 3 | conv2-2 | 6422528 | 115605504 | | +| 4 | conv2-3 | 6422528 | 115605504 | | +| 5 (Exit1) | conv2-4 | 6422528 | 115605504 | 63.91% | +| 6 | conv3-1 | 3211264 | 57802752 | | +| 7 | conv3-2 | 3211264 | 115605504 | | +| 8 | conv3-3 | 3211264 | 115605504 | | +| 9 (Exit2) | conv3-4 | 3211264 | 115605504 | 65.36% | +| 10 | conv4-1 | 1605632 | 57802752 | | +| 11 | conv4-2 | 1605632 | 115605504 | | +| 12 | conv4-3 | 1605632 | 115605504 | | +| 13 (Exit3) | conv4-4 | 1605632 | 115605504 | 67.64% | +| 14 | conv5-1 | 802816 | 57802752 | | +| 15 | conv5-2 | 802816 | 115605504 | | +| 16 | conv5-3 | 802816 | 115605504 | | +| 17 | conv5-4 | 802816 | 115605504 | | +| | avg pool | 16384 | 1229312 | | +| 18 (Exit4) | fc | 32000 | 1023000 | 68.96% | + +### 5.3.2 Motivation + +The performance of the application AI/ML inference can be evaluated by two primary metrics: end-to-end application AI/ML inference latency and inference accuracy. The end-to-end latency in collaborative AI inference involving mobile devices and cloud/edge server generally comprises four key components: the inference computation latency on the mobile device, the transmission latency for AI/ML model intermediate outcomes from the mobile devices to the network, the inference computing latency within the edge/cloud server, and the transmission latency for the inference outcomes from the network to the mobile device. Figure 5.3.2-1 illustrates the end-to-end inference latency for collaborative AI inference between mobile devices and edge/cloud server, with the total inference latency represented as the sum of T1, T2, T3, and T4. The end-to-end latency of collaborative AI/ML inference is subject to multiple determinants. Latency T1 is influenced by both the complexity of the AI/ML model deployed on the mobile device and the device's computing capability. It is worth noting that the AI/ML model inference accuracy usually increases with the AI/ML model complexity. Latency T2 depends on the data size of the AI/ML model intermediate outputs, the radio interface and backhaul connection conditions. Latency T3 is contingent upon the complexity of the AI/ML model deployed on the edge/cloud server and the computing capability of the server. Meanwhile, latency T4 hinges on the data size of the inference result, the radio interface and backhaul connection conditions. The above analysis of the impact on latency T1~T4 indicates that the end-to-end latency of collaborative AI inference highly depends on both the communication and computational capabilities of the mobile device and the network. To assure the end-to-end collaborative AI inference performance, the joint communication and computing resources optimization is desired. + +The objective of this use case is to investigate how O-RAN architecture could be leveraged to support the collaborative AI/ML inference between the mobile device and the network. + +![Diagram illustrating the AI/ML collaborative inference between a mobile device and an edge/cloud server. The mobile device (left) computes model layers 1 to 10 with latency T1. The intermediate outcomes are transmitted to the edge/cloud server (right) with latency T2. The server computes model layers 11 to the output with latency T3. The inference result is transmitted back to the mobile device with latency T4. Below the diagram, a block diagram shows the O-RAN architecture: O-CU/O-DU, xApp, RIC, lite CN (e.g., UPF), Hypervisor (VM/Container), and Infrastructure. A note states: 'NOTE: the CN is out of O-RAN scope'.](aa0c18a4505e15399667959fcd3c44e8_img.jpg) + +Model layer 1 to 10 are computed at mobile device +computing latency: T1 + +AI/ML model intermediate outcomes +transmission latency: T2 + +AI inference result transmission latency: T4 + +Model layer 11 to output +are computed at +edge/cloud server +computing latency: T3 + +Inference result + +NOTE: the CN is out of O-RAN scope + +Diagram illustrating the AI/ML collaborative inference between a mobile device and an edge/cloud server. The mobile device (left) computes model layers 1 to 10 with latency T1. The intermediate outcomes are transmitted to the edge/cloud server (right) with latency T2. The server computes model layers 11 to the output with latency T3. The inference result is transmitted back to the mobile device with latency T4. Below the diagram, a block diagram shows the O-RAN architecture: O-CU/O-DU, xApp, RIC, lite CN (e.g., UPF), Hypervisor (VM/Container), and Infrastructure. A note states: 'NOTE: the CN is out of O-RAN scope'. + +**Figure 5.3.2-1: The AI/ML collaborative inference between mobile device and edge/cloud server** + +### 5.3.3 Proposed Solution #1 + +O-RAN could provide both the edge computing capabilities and the communication assurance for the collaborative AI inference scenarios. This also helps to facilitate the joint communication and computing resource optimization to ensure the end-to-end performance. + +Firstly, in O-RAN system, O-Cloud infrastructure can provide high-quality computing resources for mobile device and network AI/ML collaborative inference. Idle O-Cloud resources can be leveraged to the deploy the AI/ML application. Compared with the collaborative AI inference between mobile device and central cloud server, AI/ML collaborative inference between mobile devices and O-Cloud is beneficial for reducing the transmission latency of AI/ML model intermediate outcomes and inference result. This also helps to potentially reduce the cost required for additional edge/cloud server deployment. To efficiently utilize the O-Cloud computing capabilities for the edge AI/ML applications, SMO could serve as an intermediary interface that translates external communication and computing requests into O-RAN internal operations. In detail, SMO could expose the computing services or integrated communication and computing services offered by O-RAN to the external entities or consumers so that external customers are able to convey their communication requirements and computing requirements. For example, in the AI/ML inference request, requirements such as computing resource requirements for AI/ML applications, end-to-end inference latency and accuracy requirements, service duration, and the number of served mobile devices, etc., could be provided to the SMO. With the service request input, SMO can orchestrate communication and computing resources to fulfill the service requirements. To enable the deployment of the edge applications (e.g., AI/ML application) on the O-Cloud from the external request, a new edge application orchestrator, i.e., RAN Edge Application Orchestrator (REAO), responsible for the edge application life cycle management, can be introduced in SMO or the existing mechanism could be reused. It can further consume the O-Cloud Deployment Management Service (DMS) to execute the deployment operation on O-Cloud. + +Secondly, Non-RT RIC and Near-RT RIC can further enable the intelligent service assurance and network performance improvement. These capabilities can be applied to collaborative AI inference, facilitating the joint communication and computing resources optimization. For example, Non-RT RIC may predict the trajectory of mobile devices, then proactively optimize communication resources at the target BS and assist to deploy AI/ML applications in advance at the target O-Cloud, etc. Near-RT RIC is capable to gather detailed information at both the UE level and the cell level. With these data and the policies received from Non-RT RIC, Near-RT RIC can help to assure the communication performance in near real-time for AI/ML inference application. + +Furthermore, O-RAN can provide RAN information including communication and computing information to network side AI/ML endpoints (which could be deployed at O-Cloud, edge or cloud servers). For example, Near-RT RIC can expose mobile device throughput, network congestion condition, radio interface latency, available computing resources, + +etc via Y1 interface. This information can be used by the application to optimize the AI/ML model split and exit decisions in adaptation to the network connection conditions and computing status (e.g., mobile devices' computing capabilities, power status, etc.). The optimized decision from application may be further notified to mobile devices and SMO and enforced by them. + +Figure 5.3.3-1 shows how O-RAN support the collaborative AI inference application, such as industrial quality inspection, in the production line scenario. + +![Figure 5.3.3-1: The AI/ML collaborative inference between mobile device and O-RAN. The diagram illustrates the interaction between an External consumer (Production Control Center), SMO (Non-RT RIC), O-Cloud (CU/DU, CN, Near RT RIC), and a mobile device. The External consumer sends a communication and computing service request (e.g., AI/ML inference request) to the SMO (2). The SMO sends communication and computing capability exposure (1a) to the External consumer and communication and computing information exposure (1b) to the mobile device. The SMO also sends an AI/ML application (split part 1) deployment (application layer operations) (3a) to the mobile device and an AI/ML application (split part 2, layer 11-output) deployment (3b) to the O-Cloud. The SMO sends an A1: service assurance policy (4) to the O-Cloud. The O-Cloud sends E2: mobile device information collection (5) to the mobile device. The mobile device sends AI/ML app split part 1 (e.g., layer 1-10) to the O-Cloud. The O-Cloud sends AI/ML app split part 2 (e.g., layer 11-output) to the mobile device. The O-Cloud is noted as being out of O-RAN scope.](94c4d9fdf1db430f6d83cb5ce9174f8c_img.jpg) + +Figure 5.3.3-1: The AI/ML collaborative inference between mobile device and O-RAN. The diagram illustrates the interaction between an External consumer (Production Control Center), SMO (Non-RT RIC), O-Cloud (CU/DU, CN, Near RT RIC), and a mobile device. The External consumer sends a communication and computing service request (e.g., AI/ML inference request) to the SMO (2). The SMO sends communication and computing capability exposure (1a) to the External consumer and communication and computing information exposure (1b) to the mobile device. The SMO also sends an AI/ML application (split part 1) deployment (application layer operations) (3a) to the mobile device and an AI/ML application (split part 2, layer 11-output) deployment (3b) to the O-Cloud. The SMO sends an A1: service assurance policy (4) to the O-Cloud. The O-Cloud sends E2: mobile device information collection (5) to the mobile device. The mobile device sends AI/ML app split part 1 (e.g., layer 1-10) to the O-Cloud. The O-Cloud sends AI/ML app split part 2 (e.g., layer 11-output) to the mobile device. The O-Cloud is noted as being out of O-RAN scope. + +**Figure 5.3.3-1: The AI/ML collaborative inference between mobile device and O-RAN** + +### 5.3.4 Proposed Solution #2 + +This solution aims to incorporate comprehensive management of CCIN consumers' AI/ML inference applications, specifically regarding the life-cycle management of collaborative AI/ML inference tasks by SMO. + +To enable O-RAN to dynamically select an AI/ML model partitioning and exit point that is suitable for the current communication and computing resource condition, and to deploy the selected AI/ML model, CCIN consumers could provide SMO with a set of certain types of AI/ML models at possible partitioning and exit points. This allows the SMO to ascertain the uplink bandwidth and computing resource requirements of the AI/ML models within the set, thereby enabling the selection of partitioning of AI/ML models based on deployment strategies generated by the Non-RT RIC. + +Additionally, CCIN consumers could provide performance requirements for the AI/ML collaborative inference task, such as end-to-end latency of AI/ML inference, the area required to be covered, etc. This enables the Non-RT RIC to generate AI/ML model deployment strategies that comply with these performance metrics based on the status of communication and computing resources. + +Since mobile device and O-Cloud AI/ML collaborative inference involves not only adjustments to the AI/ML models deployed on the O-Cloud side but also adjustments on the mobile device side, the AI/ML models deployed on mobile device are always intended to compute collaboratively with those on O-Cloud. If the O-Cloud deploys AI/ML inference model from the (n+1)th layer to the output layer, then the mobile device side needs to deploy the AI/ML model for + +layers 1 to (n). Consequently, O-RAN needs to communicate the decision on the O-Cloud side AI/ML model selection to CCIN consumers, enabling them to inform the mobile device side about the AI/ML model that need to be deployed. + +Figure 5.3.4-1 illustrates an example of O-RAN implementing AI/ML collaborative inference computing task between mobile device and O-Cloud. Herein, CCIN consumers notify the SMO of the AI/ML models (For instance, a set of AI/ML models that categorized with different AI/ML model partitioning and exit points.) and the performance requirements for the mobile device and O-Cloud AI/ML collaborative inference (such as end-to-end latency of AI/ML inference, the area desired to be covered, etc.) through the consumption of CCIN service. The Non-RT RIC, based on current communication and computational resources, generates AI/ML model deployment strategy and notifies the CCIN consumers. CCIN consumers then complete the deployment of AI/ML model on the mobile device side, while the SMO (for example, REAO within the SMO that deploys edge applications) completes the deployment of AI/ML model on O-Cloud. By monitoring of the AI/ML collaborative computing task, the Non-RT RIC can collect the communication status of the mobile device from the Near-RT RIC and generate AI/ML model adjustment strategy based on the current communication and computing status of the mobile device and the O-Cloud. The AI/ML model adjustment strategies are also communicated to CCIN consumers to update the AI/ML model on the mobile device side. + +![Figure 5.3.4-1: AI/ML inference application selection and deployment performed by O-RAN. The diagram shows the interaction between an External consumer (e.g., Production Control Center), SMO (Non-RT RIC), O-Cloud (Near RT RIC, CU/DU, CN, xApp), and mobile devices. The process involves: 1. External consumer exposing capabilities to SMO. 2. External consumer requesting AI/ML models from SMO. 3. SMO selecting and deploying AI/ML model split parts to O-Cloud and mobile devices. 4. SMO providing service assurance policies to O-Cloud. 5. O-Cloud collecting mobile device information and performing inference.](d18909a80d3f1827d2e08c41747b10ad_img.jpg) + +The diagram illustrates the AI/ML inference application selection and deployment process in O-RAN. It shows the following components and their interactions: + +- External consumer, e.g., Production Control Center:** Collects communication and computing information, sends communication and computing requests to SMO, and deploys AI/ML models to mobile devices. +- SMO (Non-RT RIC):** + - ①. Communication and computing capability exposure: Receives information from the external consumer. + - ②. Communication and computing service request, e.g., AI/ML inference task request. A set of AI/ML models that includes AI/ML model partitioning and exit points: Receives requests from the external consumer. + - ③. AI/ML model (split part 2, e.g., layer 11~output) selection and deployment: Selects and deploys model split parts to the O-Cloud. + - ④. A1: service assurance policy: Provides policies to the O-Cloud. +- O-Cloud:** + - Near RT RIC:** Collects mobile device information (⑤. E2: mobile device information collection) and performs inference. + - CU/DU:** Connected to the Near RT RIC. + - CN (e.g., UPF):** Connected to the CU/DU. + - xApp:** Connected to the Near RT RIC. +- Mobile Devices:** + - AI/ML app split part 1, e.g., layer 1~10:** Deployed on the mobile device. + - AI/ML app split part 2, e.g., layer 11~output:** Deployed on the O-Cloud. + +NOTE: the CN is out of O-RAN scope + +Figure 5.3.4-1: AI/ML inference application selection and deployment performed by O-RAN. The diagram shows the interaction between an External consumer (e.g., Production Control Center), SMO (Non-RT RIC), O-Cloud (Near RT RIC, CU/DU, CN, xApp), and mobile devices. The process involves: 1. External consumer exposing capabilities to SMO. 2. External consumer requesting AI/ML models from SMO. 3. SMO selecting and deploying AI/ML model split parts to O-Cloud and mobile devices. 4. SMO providing service assurance policies to O-Cloud. 5. O-Cloud collecting mobile device information and performing inference. + +Figure 5.3.4-1: AI/ML inference application selection and deployment performed by O-RAN + +### 5.3.5 Benefits of O-RAN Architecture + +The O-RAN system presents several advantages in the collaborative AI/ML inference scenario. First, the idle computing resources of O-Cloud can be shared with AI/ML inference applications. Furthermore, Non-RT RIC and Near-RT RIC empowers joint communication and computing resources optimization to ensure the collaborative AI/ML inference end-to-end latency and accuracy performance. + +## 5.4 Use Case 4: XR rendering collaboration + +### 5.4.1 Background Information + +As a disruptive technology that brings new interactive experience, eXtended Reality (XR) has attracted considerable attention from content providers, mobile network operators, vertical industry customers, and so on. By design, a unique feature of XR is a new device form factor replacing or complementing handheld smartphones with wearable head-mounted displays or smart glasses. New devices (i.e., glasses or head mounted displays) impose strict requirements on user equipment (UE) power consumption, performance, and heat dissipation. Consequently, XR devices cannot do all the computations (i.e., Figure 5.4.1-1(1)) but require assistance from other nodes [i.21]. + +XR applications often require high-quality visuals and real-time interactions, which can be demanding in terms of latency and bandwidth requirements. Figure 5.4.1-1 illustrates the collaboration between different types of computing nodes and XR devices, where blue lines represent communication latency and orange lines represent the processing in computing nodes. On the one hand, RAN computing, brings rendering and computing service closer to users, allowing for ultra-low communication latency and reliability assurance for XR applications. On the other hand, RAN computing capability is weaker than cloud computing, which may cause the larger computing delay [i.22]. In order to provide users with immersive experience and ensure real-time interaction, the delay of interaction must be small enough, which puts forward new requirements for both radio network and computing resources. + +![Figure 5.4.1-1: Collaboration between different types of computing nodes and XR devices. The diagram shows four scenarios (1, 2, 3, 4) illustrating the flow of data and processing between XR devices, RAN computing, Edge Computing, and Center Cloud Computing. A blue arrow at the top indicates 'Increased communication latency' from left to right. An orange arrow at the bottom indicates 'Strengthened computing capability' from left to right. Scenario (1) shows XR devices connected to RAN computing. Scenario (2) shows XR devices connected to RAN computing, which is connected to Edge Computing. Scenario (3) shows XR devices connected to RAN computing, which is connected to Edge Computing, which is connected to Center Cloud Computing. Scenario (4) shows XR devices connected to RAN computing, which is connected to Edge Computing, which is connected to Center Cloud Computing, which is connected back to RAN computing.](085b0051ef7a701c6428b2041daf233c_img.jpg) + +Figure 5.4.1-1: Collaboration between different types of computing nodes and XR devices. The diagram shows four scenarios (1, 2, 3, 4) illustrating the flow of data and processing between XR devices, RAN computing, Edge Computing, and Center Cloud Computing. A blue arrow at the top indicates 'Increased communication latency' from left to right. An orange arrow at the bottom indicates 'Strengthened computing capability' from left to right. Scenario (1) shows XR devices connected to RAN computing. Scenario (2) shows XR devices connected to RAN computing, which is connected to Edge Computing. Scenario (3) shows XR devices connected to RAN computing, which is connected to Edge Computing, which is connected to Center Cloud Computing. Scenario (4) shows XR devices connected to RAN computing, which is connected to Edge Computing, which is connected to Center Cloud Computing, which is connected back to RAN computing. + +**Figure 5.4.1-1: Collaboration between different types of computing nodes and XR devices** + +3GPP TR 38.838 [i.23] defines the evaluation methodology for XR studies in Release-17, including the modeling of XR applications, simulation scenarios, traffic models, KPIs, and simulation parameters. 3GPP TR 22.261 [i.24] defines the Cloud/Edge/Split Rendering as an additional high data rate and low latency service and provides corresponding requirements on the 5G system. In addition to the conversational service category, Interactive (Streaming), Passive Streaming, Download, and Split Compute/Rendering are identified as new delivery categories in 3GPP TR 26.928 [i.25], which also introduces different distributed computing architectures for XR. 3GPP TR 23.748 [i.26] defines the necessary modifications to 5G system architecture to enhance Edge Computing. Specifically, this study is investigating mechanisms to discover connectivity to available Edge Computing resources (e.g. using DNS), mobility improvements for both UE consuming Edge Computing services and for Edge Application Servers, and for network capability + +exposure towards the Edge Application Server. In addition, in 3GPP TR 23.758 [i.27] and 3GPP TS 23.558 [i.28] a new set of application layer interfaces for Edge Computing are identified that may potentially be useful for integration of Edge Computing. Specifically, the interfaces will enable application-layer discovery of Edge Application Servers, capability exposure towards the Edge Application Server, and procedures for onboarding, registration, and lifecycle management of Edge Applications. + +### 5.4.2 Motivation + +Figure 5.4.2-1 shows the XR rendering collaboration between RAN and XR devices. In this type of service, the terminal collects holographic information such as the user's geographic location, orientation, manipulation, and five-senses through sensors. With the help of a high-speed and stable radio network, the information is transmitted to the RAN edge computing platform and the cloud through the uplink. Then, the RAN edge or cloud rendering server invokes computing resources to render the screen in real time, and the processed holographic information will be transmitted to the user's terminal device through the downlink after being encoded and compressed. Finally, the terminal device restores the above information to the user. + +![Figure 5.4.2-1: XR rendering collaboration between RAN and XR devices. The diagram shows an XR device on the left and RAN computing on the right. A blue arrow labeled 'holographic information' points from the XR device to the RAN computing. A blue arrow labeled 'processed holographic information' points from the RAN computing back to the XR device. The RAN computing node is also labeled 'processing' with a circular arrow.](31d37d25a61c69b969b81b68aa293bd0_img.jpg) + +Figure 5.4.2-1: XR rendering collaboration between RAN and XR devices. The diagram shows an XR device on the left and RAN computing on the right. A blue arrow labeled 'holographic information' points from the XR device to the RAN computing. A blue arrow labeled 'processed holographic information' points from the RAN computing back to the XR device. The RAN computing node is also labeled 'processing' with a circular arrow. + +**Figure 5.4.2-1: XR rendering collaboration between RAN and XR devices** + +However, there are two major limitations with existing computation offloading approaches. + +Firstly, there is a lack of alignment between communication and computing decisions. Although computing is brought closer to the RAN, the existing architecture still manages communication and computing separately, resulting in sub-optimal performance. 3GPP TR 22.261 [i.22] defines motion-to-photon latency in the range of 7ms to 15ms while maintaining the required resolution of up to 8k giving user data rate of up to 1Gbit/s. Assuming the service requirements for motion-to-photon latency is 10ms, three RAN computing nodes with different bandwidth load and computing load can be chosen as the server, as shown in Figure 5.4.2-2. If choosing the computing node based on the best computing delay it will be the node 1, the E2E delay is 13ms. If choosing the computing node based on the best communication latency it will be the node 2, the E2E delay is 14ms. If choosing the computing node based on both of the status it will be the node 3, the E2E delay is 10ms and meets the service requirements. To ensure E2E delay without resource wastage of both radio network and computing resources, it is essential to align the decisions of communication and computing. + +![Figure 5.4.2-2: RAN computing nodes with different bandwidth load and computing load. The diagram shows three scenarios (1), (2), and (3) of XR device to RAN computing collaboration. Each scenario includes a diagram of the communication and computing paths with associated delays and a bar chart showing the relative loads for communication and computing. Scenario (1) shows a 9ms communication delay and 4ms computing delay, with a high communication load and low computing load. Scenario (2) shows a 4ms communication delay and 10ms computing delay, with a low communication load and high computing load. Scenario (3) shows a 5ms communication delay and 5ms computing delay, with a balanced communication and computing load.](9556fe643c8a3cebd8e10274d9562bcc_img.jpg) + +Figure 5.4.2-2: RAN computing nodes with different bandwidth load and computing load. The diagram shows three scenarios (1), (2), and (3) of XR device to RAN computing collaboration. Each scenario includes a diagram of the communication and computing paths with associated delays and a bar chart showing the relative loads for communication and computing. Scenario (1) shows a 9ms communication delay and 4ms computing delay, with a high communication load and low computing load. Scenario (2) shows a 4ms communication delay and 10ms computing delay, with a low communication load and high computing load. Scenario (3) shows a 5ms communication delay and 5ms computing delay, with a balanced communication and computing load. + +**Figure 5.4.2-2: RAN computing nodes with different bandwidth load and computing load** + +Secondly, there is a lack of united orchestration among multiple users in adapting to resource-limited edge environments. An adaptive design focusing on a single-user offloading pipeline can be duplicated for multiple users, but this can lead to poor resource efficiency. Figure 5.4.2-3 shows the situation that XR devices are associated with the closest BS. Without united orchestration among multiple users, some RAN nodes may become overloaded while others are underutilized, resulting in inefficient resource allocation. To address this issue, it is necessary to coordinate the decisions of multiple users holistically. + +NOTE: Without specification, the "resource" mentioned above refers to the available communication and computing capabilities within RAN. + +![Figure 5.4.2-3: Lack of united orchestration among multiple users in adapting to resource-limited edge environments. The diagram illustrates two scenarios: 'heavy load' and 'light load'. In the 'heavy load' scenario, three XR devices are connected to a central RAN computing node. A legend indicates that communication is represented by a blue bar and computing by an orange bar. In the 'light load' scenario, two XR devices are connected to a central RAN computing node, and a third XR device is connected to a separate RAN computing node. A legend indicates that communication is represented by a blue bar and computing by an orange bar.](0b903a221c9442cb1cb810d626e28111_img.jpg) + +Figure 5.4.2-3: Lack of united orchestration among multiple users in adapting to resource-limited edge environments. The diagram illustrates two scenarios: 'heavy load' and 'light load'. In the 'heavy load' scenario, three XR devices are connected to a central RAN computing node. A legend indicates that communication is represented by a blue bar and computing by an orange bar. In the 'light load' scenario, two XR devices are connected to a central RAN computing node, and a third XR device is connected to a separate RAN computing node. A legend indicates that communication is represented by a blue bar and computing by an orange bar. + +**Figure 5.4.2-3: Lack of united orchestration among multiple users in adapting to resource-limited edge environments** + +Therefore, a joint design approach is required for computing node selection, computing resource allocation, and radio resource optimization. Leveraging modern AI technologies, computational tasks or resources can be automatically scheduled and orchestrated along with the optimization of communication resources. This integrated approach enables more efficient utilization of computing resources, thereby reducing wastage in redundant hardware capital expenditures (CAPEX) and operating expenses (OPEX). + +### 5.4.3 Proposed Solution + +As shown in Figure 5.4.3-1, XR rendering collaboration over SMO consists of the following steps: + +- 0) Application awareness: External consumer collects the XR service requirements and application status from the XR devices and XR edge applications. +- 1) Capability exposure: communication and computing capabilities within RAN are exposed by SMO (1a) or via Y1 (1b) interface to external consumer. For example, levels of E2E delay can be provided for XR rendering tasks. +- 2) Analysis and decision for service request: external consumer analyzes the XR service requirements and the capabilities within RAN, and then determines the service request for capabilities in O-RAN. +- 3) Service request: external consumer requests communication and computing service in O-RAN. +- 4) Optimization and decision analysis: potentially utilize AI/ML models to analyze the service request and determine the resource demand and policy for XR rendering assurance in O-RAN. + +#### 5) Execution: + +- 5a) Deploy or scale the cloud resources of E2 nodes (i.e., O-CU, O-DU) via O2 interface. +- 5b) Reconfigure the E2 nodes via the O1 interface to guarantee radio transmission for XR rendering (e.g., cell-level spectrum allocation). +- 5c) Create A1 policy for XR rendering assurance. +- 5d) Deploy or scale the cloud resources of XR edge applications on the O-Cloud platform. +- 5e) (Out of O-RAN scope) Deploy XR applications on UE or notify UE the default XR edge application and/or the default communication node. + +NOTE1: Step 5a. to 5d. can be freely combined or skipped to guarantee the XR rendering assurance, depending on the specific requirements of the XR service. + +NOTE2: External consumers could be global orchestrator or the edge enabler server in 3GPP [i.28]. + +![Figure 5.4.3-1: XR rendering collaboration over SMO. This diagram illustrates the architecture and interactions for XR rendering collaboration. The central component is the 'Service management & Orchestration Framework' (SMO), which contains a 'Non-RT RIC' with '4. Optimization and decision analysis'. The SMO is connected to the 'Near-RT RIC' (containing 'E2 control/ policy for XR rendering assurance') via the 'A1' interface. The Near-RT RIC is connected to 'E2 Nodes' (containing 'E2 report for XR application') via the 'E2' interface. The E2 Nodes are connected to the 'O-Cloud' via the 'O1' interface. The O-Cloud is connected to 'XR edge Applications*' via the 'Y1' interface. The XR edge Applications are connected to 'XR devices' via 'XR rendering collaboration'. The External consumer is connected to the SMO via '1a. Capability exposure' and '3. Service request'. The External consumer is connected to the XR devices via '0. Application awareness' and '5e. Execution on UE'. The diagram also shows '5a. Deploy or scale the E2 nodes' and '5b. Reconfigure the E2 nodes' as actions related to the O1 interface, and '5c. A1 Policy for XR rendering assurance' as an action related to the A1 interface. A legend indicates that orange lines represent existing O-RAN components, green lines represent potential enhancements, and blue lines represent components out of O-RAN scope. A note states that XR edge applications can share infrastructure resources provided for O-RAN NFs.](82e2284adc899d46d1cc481b9a8c5d9e_img.jpg) + +Figure 5.4.3-1: XR rendering collaboration over SMO. This diagram illustrates the architecture and interactions for XR rendering collaboration. The central component is the 'Service management & Orchestration Framework' (SMO), which contains a 'Non-RT RIC' with '4. Optimization and decision analysis'. The SMO is connected to the 'Near-RT RIC' (containing 'E2 control/ policy for XR rendering assurance') via the 'A1' interface. The Near-RT RIC is connected to 'E2 Nodes' (containing 'E2 report for XR application') via the 'E2' interface. The E2 Nodes are connected to the 'O-Cloud' via the 'O1' interface. The O-Cloud is connected to 'XR edge Applications\*' via the 'Y1' interface. The XR edge Applications are connected to 'XR devices' via 'XR rendering collaboration'. The External consumer is connected to the SMO via '1a. Capability exposure' and '3. Service request'. The External consumer is connected to the XR devices via '0. Application awareness' and '5e. Execution on UE'. The diagram also shows '5a. Deploy or scale the E2 nodes' and '5b. Reconfigure the E2 nodes' as actions related to the O1 interface, and '5c. A1 Policy for XR rendering assurance' as an action related to the A1 interface. A legend indicates that orange lines represent existing O-RAN components, green lines represent potential enhancements, and blue lines represent components out of O-RAN scope. A note states that XR edge applications can share infrastructure resources provided for O-RAN NFs. + +Figure 5.4.3-1: XR rendering collaboration over SMO + +### 5.4.4 Benefits of O-RAN Architecture + +O-Cloud in O-RAN provides the necessary computing, storage, and communication resources to host and execute the virtualized functions and applications required for O-RAN operations. O-Cloud can extend its capabilities to the network edge, reducing latency and improves the performance of XR applications by processing data closer to the source. + +O-RAN's open interfaces and AI/ML based architecture will enable the challenging mechanisms of XR rendering collaboration to be implemented. For example, Near-RT RIC collects rich data on radio conditions and computing capabilities in RAN, as well as information on XR applications. By training AI models with these data, the performance of XR rendering collaboration tasks can be significantly enhanced with jointly optimizing computing node selection, computing resource allocation and radio resource optimization. + +The purpose of this use case is to perform distributed rendering of co-orchestration of communication resources and computing resources in O-RAN to improve the experience of XR users. + +## 5.5 Use Case 5: Computing Resource Scheduling in V2X Communications + +### 5.5.1 Background Information + +It is expected that there will be approximately 8 million autonomous or semi-autonomous vehicles on the road by 2025 [i.29]. As an enabling technology, Vehicle-to-Everything (V2X) communication is pivotal in paving the way for the Intelligent Traffic System and autonomous vehicles by facilitating the exchange of crucial information among vehicles, infrastructure, and pedestrians. This exchange encompasses critical data, including real-time updates on traffic conditions, impending road hazards, and precise speed limits, to improve decision-making and prevent accidents. + +Within the realm of V2X communications, the intersection is one of the most challenging scenarios. The various ways of transportation (e.g. vehicles, pedestrians) coupled with densely constructed buildings contributes to the complexity of traffic conditions, resulting in a large amount of data gathered from diverse sources for comprehensive sensing and collision avoidance. As shown in Figure 5.5.1-1, Vehicle 1 travels straight through the intersection, while Vehicle 2 maintains a safe distance behind Vehicle 1, intending to turn left. During the drive, there are several risks. + +- Vehicle 1 risks colliding with Vehicle 3. +- Vehicle 1 or Vehicle 3 risks colliding with the pedestrian 2 (if he suddenly rushes from behind Building 2 and turns left). However, either Vehicle 1 and Vehicle 3 cannot sense the pedestrian timely due to the blocking by Building 2. +- Vehicle 2 risks colliding with other vehicles and pedestrian (e.g., Vehicle 3 and pedestrian 1). Due to the blocking by Vehicle 1 and Building 1, Vehicle 2 is unable to accurately sense traffic conditions ahead and to the left in real-time and has to obtain information by exchanging information with other vehicles or infrastructures, which may result in high latency and high risk of collision. + +![Figure 5.5.1-1: An illustration of the potential collisions at intersections. The diagram shows a four-way intersection with buildings (Building 1, Building 2), vehicles (Vehicle 1, Vehicle 2, Vehicle 3), and pedestrians (Pedestrian 1, Pedestrian 2). Vehicle 1 is moving straight through the intersection. Vehicle 2 is behind Vehicle 1, intending to turn left. Vehicle 3 is approaching from the right. Pedestrian 1 is near Building 1, and Pedestrian 2 is near Building 2. Red dashed lines and 'risk' labels indicate potential collision points between Vehicle 1 and Vehicle 3, and between Vehicle 1 and Pedestrian 2.](cca81b7a324e9c34bd90e43e332a66b4_img.jpg) + +Figure 5.5.1-1: An illustration of the potential collisions at intersections. The diagram shows a four-way intersection with buildings (Building 1, Building 2), vehicles (Vehicle 1, Vehicle 2, Vehicle 3), and pedestrians (Pedestrian 1, Pedestrian 2). Vehicle 1 is moving straight through the intersection. Vehicle 2 is behind Vehicle 1, intending to turn left. Vehicle 3 is approaching from the right. Pedestrian 1 is near Building 1, and Pedestrian 2 is near Building 2. Red dashed lines and 'risk' labels indicate potential collision points between Vehicle 1 and Vehicle 3, and between Vehicle 1 and Pedestrian 2. + +**Figure 5.5.1-1: An illustration of the potential collisions at intersections** + +In collision warning scenarios, the latency requirement for data collection and computing are in few milliseconds (e.g., the maximum end-to-end latency for cooperative collision avoidance in the advanced driving scenario is 10ms.) [i.30], so that the results and warns can be fed back to vehicles and pedestrians in timely manner. To fulfill the strict latency demand, it is essential to process these tasks in one or several optimal computing nodes, e.g., the central cloud, edge cloud, radio edge cloud, device edge cloud etc. Since the end-to-end latency is limited by the computing latency and network latency, the optimal offloading choice cannot be found by either optimize the network or computing resource. Hence, joint optimization of network and computing resource is needed. For example, the road status sensing data from Vehicle 1, Vehicle 3 and Pedestrian 2 must be communicated and processed and the result fed back within milliseconds to avoid the collision between them. + +To reduce network latency, it is desirable to process the data locally in vehicles. However, the computing resources of vehicles may be limited, which may not satisfy the task requirements in terms of computing resources and capabilities and could also lead to high computing latency. Therefore, it may be desired to offload all or part of the data processing to the best edge server (e.g., the server completes data processing with the lowest latency, lowest energy consumption.) through joint optimization of network and computing resources. However, since the task requirements on computing resources (e.g., the required type of computing resources) are diverse and the availability of computing resources is dynamic, it is of great important to enable joint communication and computing resources optimization. What is worse, there are other data to be processed, such as navigation requests from other vehicles, requests for entertainment-related services from passengers, etc., which also consume limited computing and communication resources and increase the difficulties. + +### 5.5.2 Motivation + +The main objective is to enable joint communication and computing resources optimization for V2X communications. In O-RAN, the global information on communication and computing resources is available over O1 and O2 interface, thus facilitating the joint communication and computing resources optimization. With the above global information, resource scheduling policies for both communication and computing can be developed in Non-RT RIC (e.g., policies in terms of CPU frequency, bandwidth and power, etc.), and communication optimization policies can be enforced by Near-RT RIC based on the near real-time UE level information (e.g., real-time link quality) . In addition, the vacant computing resources in O-Cloud can provide edge computing services in case of low network load, which further facilitates the low-latency computing in V2X communications. + +### 5.5.3 Proposed Solution + +O-RAN can provide edge computing capabilities and communication assurance for computing in V2X. The vacant O-Cloud resources and collaboration between Non-RT RIC and Near-RT RIC facilitate on-demand resource allocation adjustments and joint optimization of communication and computing resource scheduling to ensure end-to-end performance. + +Fig. 5.5.3-1 illustrates how O-RAN can facilitate computing in V2X communications, where the O-Cloud is used as the computing entity in O-RAN. + +![Figure 5.5.3-1: An illustration of O-RAN assisted computing in V2X communications. The diagram shows the interaction between external consumers, SMO (Service Management and Orchestration), Non-RT RIC, Near-RT RIC, O-Cloud (O-CU/O-DU, xApp), Hypervisor (VM/Container), Infrastructure, and edge/cloud server. The flow includes: 1. Data collection from Near-RT RIC to SMO; 2. Data collection from O-Cloud to SMO; 3. Data collection from edge/cloud server to SMO; 4. Communication and computing service request from external consumers to SMO; 5. Communication and computing capability exposure from SMO to external consumers; 6. A1: service assurance policy or AI model from SMO to Near-RT RIC; 7. E2: Device information collection from Near-RT RIC to O-Cloud; 8. Y1: Communication and computing information exposure from edge/cloud server to SMO.](dd7d08ae46512de8e8ec16fd9a8a893d_img.jpg) + +Figure 5.5.3-1: An illustration of O-RAN assisted computing in V2X communications. The diagram shows the interaction between external consumers, SMO (Service Management and Orchestration), Non-RT RIC, Near-RT RIC, O-Cloud (O-CU/O-DU, xApp), Hypervisor (VM/Container), Infrastructure, and edge/cloud server. The flow includes: 1. Data collection from Near-RT RIC to SMO; 2. Data collection from O-Cloud to SMO; 3. Data collection from edge/cloud server to SMO; 4. Communication and computing service request from external consumers to SMO; 5. Communication and computing capability exposure from SMO to external consumers; 6. A1: service assurance policy or AI model from SMO to Near-RT RIC; 7. E2: Device information collection from Near-RT RIC to O-Cloud; 8. Y1: Communication and computing information exposure from edge/cloud server to SMO. + +**Figure 5.5.3-1: An illustration of O-RAN assisted computing in V2X communications** + +First, SMO retrieves data from Near-RT RIC, E2 nodes, O-Cloud, and/or edge/cloud servers to get the communication and computing resources information, which mainly includes but is not limited to information about available computing resources (e.g., resource type, CPU/GPU frequency and storage) and communication resources (e.g., + +network load, available bandwidth, link quality). The mentioned information of O-Cloud can be retrieved over the O2 interface, while the communication resource information can be obtained via the O1 interface from O-CU and O-DU. Also, the related information of external edge/cloud servers can be retrieved through the information exposure between external edge/cloud servers and SMO. + +Next, SMO exposes the computing services or integrated communication computing services provided by O-RAN to external entities, e.g., vehicles, pedestrians and other third-party consumers, so that external customers can send their service requests. The service request information can include but is not limited to data size, required computing resource type, latency deadline of the contained tasks. + +NOTE: The security related consideration is for further study. + +Then, Non-RT RIC trains the AI model to generate policies based on task requirements and available computing and communication resources. The policies mainly include but are not limited to task offloading strategies and/or the joint resource allocation/adjustment strategies of O-CUs/DUs (e.g. offload tasks to one of the O-DUs and allocate CPU frequency and bandwidth to these tasks based on non-real-time information), where the communication resources allocation/adjustment strategies can be further enforced and sent from Near-RT RIC to O-CUs/DUs (e.g., RAN optimization policies based on near real-time link quality). + +### 5.5.4 Benefits of O-RAN Architecture + +The O-RAN system presents several advantages in joint communication and computing resources optimization for V2X scenarios with a large amount of data to be processed in low latency. The vacant O-Cloud-based computing resources can be shared with edge applications. In addition, the Non-RT RIC can perform joint communication and computing resources optimization, and Near-RT RIC facilitates the RAN behaviour optimization based on the information obtained through E2 interface. In summary, O-RAN architecture provides necessary ingredients to facilitate computing for V2X scenarios. + +## 5.6 Use case 6: Exposure of performance information to assist computing resource scheduling + +### 5.6.1 Background Information + +Computing task performance information are used to monitor the loading conditions of virtual compute resources of computing tasks that include computing task memory usage, CPU occupancy rate, data throughput etc... + +ETSI NFV defines the use case of performance managements and performance metrics. Monitoring parameters associated with the compute related measurements and of interest for a VNF can be declared in the VNFD (see ETSI GS NFV-IFA 011 [i.35]). The measurements can be used as the triggers to the scale VNF operation (see clause 7.2.4 in ETSI GS NFV-IFA 008 [i.36]). + +The Kubernetes (K8s) API server provides supervision data about the Kubernetes objects, such as pods, processes and components use this information to track whether pods are being launched and maintained as expected. These cluster state metrics can also provide a high-level view of cluster and its state. + +### 5.6.2 Motivation + +In CCIN, computing resource orchestrator should continuously supervising the performance of running computing tasks. Reporting of running computing tasks performance information will assist the computing resource orchestrator to make decision on deploying a computing task to a new cloud node or triggering to scale a computing task. + +And this can also help the computing resource orchestrator to measure computing task's actual resource usage, which helps for evaluating the adequacy of a candidate cloud node to execute the computing task during mobility. + +### 5.6.3 Proposed Solution + +#### 5.6.3.1 Performance information reporting triggers redeployment of a computing task + +When a VNF/App is successfully deployed on an O-Cloud node, SMO collects the performance information of this VNF/App and computing resource information from Cloud Nodes distributed in various geographical locations on the O-Cloud through the O1 or O2 interface. If current O-Cloud node's performance does not meet the requirements of the VNF/App, computing resource orchestrator may trigger SMO to redeploy the VNF/App via the O2 interface. + +As shown in Figure 5.6.3.1-1, Node1 and Node2 provide computing resource at the edge cloud for UEs, and the coverage scope of cell shows as green in the figure. Through performance information reporting, when the orchestrators find that Node1 does not meet the computing resource requirements, the network may configure Node2 to serve the UE. + +![Figure 5.6.3.1-1: Computing task orchestration based on performance information. The diagram shows a network architecture where External Clients connect to an SMO (Service Management Orchestrator). The SMO manages an O-Cloud (represented by a green oval) containing O-Cloud Node 1 and O-Cloud Node 2. O-Cloud Node 1 hosts a VNF (Virtual Network Function). The O-Cloud is connected to E2 Nodes (CU DU) via the E2 interface. The E2 Nodes are connected to O-RU (Open Radio Unit) via the Open FI (CU-R Plane, M-Plane) interface. The O-RU is connected to a UE (User Equipment). The SMO also connects to Near-RT RIC 1 (Near-Real Time Resource Intelligent Controller) via the O1 interface. Near-RT RIC 1 is connected to E2 Nodes via the E2 interface. The SMO also connects to O-Cloud Node 2 via the O2 interface. The coverage scope of the cell is indicated by a green oval.](61320fbaf368680e25eb1cbd4097f2e4_img.jpg) + +Figure 5.6.3.1-1: Computing task orchestration based on performance information. The diagram shows a network architecture where External Clients connect to an SMO (Service Management Orchestrator). The SMO manages an O-Cloud (represented by a green oval) containing O-Cloud Node 1 and O-Cloud Node 2. O-Cloud Node 1 hosts a VNF (Virtual Network Function). The O-Cloud is connected to E2 Nodes (CU DU) via the E2 interface. The E2 Nodes are connected to O-RU (Open Radio Unit) via the Open FI (CU-R Plane, M-Plane) interface. The O-RU is connected to a UE (User Equipment). The SMO also connects to Near-RT RIC 1 (Near-Real Time Resource Intelligent Controller) via the O1 interface. Near-RT RIC 1 is connected to E2 Nodes via the E2 interface. The SMO also connects to O-Cloud Node 2 via the O2 interface. The coverage scope of the cell is indicated by a green oval. + +**Figure 5.6.3.1-1: Computing task orchestration based on performance information** + +Entities/resources involved in the use case: + +- 1) SMO: + - a) Support for collecting and analysing VNF/App performance information from O-Cloud. + - b) Support for redeployment or scale-in/scale-out VNF/App via O2. +- 2) O-Cloud: + - a) Support for computing related inventory and updated VNF/App performance information with required granularity to SMO over O2 interface. + - b) Support for deploying of a VNF/App or scaling a VNF/App +- 3) Orchestrator/Application Server: + - a) Request/subscribe VNF/App performance/computing information from SMO. + - b) Response for deploy/scale VNF/App on O-Cloud. + +The whole procedure is presented in Table 5.6.3.1-1, illustrated by Figure. 5.6.3.1-2. + +**Table 5.6.3.1-1: Performance information reporting triggers redeployment of a computing task** + +| Use Case Step | Description of the Step | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | Performance information reporting assist redeployment of a computing task | +| Actors and Roles | SMO, O-Cloud, orchestrators from other clouds/application server | +| Assumptions | All relevant functions and components are instantiated.
O2 interface connectivity is established with SMO. | +| Pre-conditions | SMO and O-Cloud are instantiated with O2 interface connectivity being established between them. | +| Begins when | Orchestrators external to the O-Cloud want to subscribe VNFs/Apps performance information of O-Cloud. | +| Step 1 (M) | Orchestrators external to the O-Cloud send VNFs/Apps performance information subscription to SMO. | +| Step 2 (M) | SMO subscribe VNFs/Apps performance information from O-Cloud Nodes. | +| Step 3 (M) | SMO response for VNFs/Apps performance information subscription to orchestrators external to the O-Cloud. | +| Step 4 (L) | SMO collect VNF/App performance information via O2/O1 interface and send the notification to indicate VNF/App performance information to orchestrators external to the O-Cloud. | +| Step 5 (M) | Performance can not fulfill the requirement, orchestrators external to the O-Cloud requests SMO to redeploy the VNF/App or App to cloud node2. SMO deploy VNF/App on node2 and VNF/App route switch from node1 to node2. | +| Step 6 (L) | SMO terminate VNF/App on node1. | +| Step 7 (M) | SMO response of redeployment of VNF/App success to orchestrators form other clouds or application servers. | +| Ends when | Orchestrators form other clouds or application servers get the response. | +| Post Conditions | N/A | + +``` + +@startuml +Skin rose +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 + +Box "Orchestrator" #lightcyan + Participant "Orchestrator" as client +End box + +Box SMO #gold + Participant "SMO" as smo +End box + +Box O_Cloud Node #lightseagreen + Participant "IMS/DMS" as ims #orange + Participant "Node 1" as ocloud1 + Participant "Node 2...Node N" as ocloud2 +End box +autonumber 1 +||| + +activate ocloud1 +== VNF/Apps performance Subscription == +client ->smo : Subscription of VNF/App performance information\n report +periodic or event trigger +autonumber 2.1 + +``` + +``` + +smo ->ims : Subscription of VNF/App performance information\n report +periodic or event trigger +smo <-ims : Response of VNF/App performance information +autonumber 3 +client <-smo : Response of VNF/App performance information +||| +loop performance data accumulation +autonumber 4.1 +ims <-> ocloud1: <> or <> VNF/App performance Information +ims <-> ocloud2: <> or <> VNF/App performance Information +ims -> smo: <> or <> VNF/App performance Information +client <- smo: Notifications to indicatee VNF/App performance +end +|| +== Performance can't fulfill the resource requirement, deploy the VNF/App or App to other +Cloud Node == +|| +autonumber 5.1 +client -> smo: Request to change the cloud node to o-Cloud node 2 +loop for each NF need to be deployed on o-Cloud node 2 +alt ETSI +note over smo, ocloud2:ETSI o-cloud Instantiate VNF/Apps refer to WG6 O2DMS ETSI IF +2.4.2.1 +else K8s (Kubernetes) +note over smo, ocloud2: K8s (Kubernetes) o-cloud Instantiate NF deployment refer to WG6 +O2DMS Kubernetes IF 3.1.2 +end +ocloud2<->ocloud1:Swtich service route to ocloud2 +deactivate ocloud1 +activate ocloud2 +end +|| + +|| +== Swtich service route to ocloud2 and terminate VNF/App instance on ocloud2 == +autonumber 6.1 + +loop for each VNF/Apps + +ims <- smo: Request to terminate the VNF/App + +alt ETSI +note over ims, ocloud1:ETSI o-cloud terminate VNF/Apps +else K8s (Kubernetes) +note over ims, ocloud1: K8s (Kubernetes) o-cloud terminate +end + +ims -> smo: Response to indicate the result of VNF/App termination +end + +|| +autonumber 7 +client <-smo :Response to indicate VNF/App node changing success +deactivate ocloud2 + +@enduml + +``` + +![Sequence diagram showing the process of redeploying a computing task based on performance information reporting. The diagram involves four main entities: Orchestrator, SMO, IMS/DMS, and O-Cloud Node (Node 1, Node 2...Node N). The process starts with a 'VNF/Apps performance Subscription' event. 1. Orchestrator sends 'Subscription of VNF/App performance information report periodic or event trigger' to SMO. 2.1 SMO sends 'Subscription of VNF/App performance information report periodic or event trigger' to IMS/DMS. 2.2 SMO sends 'Response of VNF/App performance information' to IMS/DMS. 3. IMS/DMS sends 'Response of VNF/App performance information' to Orchestrator. A loop '[performance data accumulation]' follows. 4.1 or VNF/App performance Information is sent from O-Cloud Node to IMS/DMS. 4.2 or VNF/App performance Information is sent from O-Cloud Node to SMO. 4.3 or VNF/App performance Information is sent from SMO to Orchestrator. 4.4 Notifications to indicate VNF/App performance are sent from Orchestrator to SMO. A decision 'Performance cant fulfill the resource requirement, deploy the VNF/App or App to other Cloud Node' leads to 5.1 Request to change the cloud node to o-Cloud node 2. A loop '[for each NF need to be deployed on o-Cloud node 2]' follows. An alt block '[ETSI]' contains 'ETSI o-cloud Instantiate VNF/Apps refer to WG6 O2DMS ETSI IF 2.4.2.1'. Another alt block '[K8s (Kubernetes) ]' contains 'K8s (Kubernetes) o-cloud instantiate NF deployment refer to WG6 O2DMS Kubernetes IF 3.1.2'. 5.2 Switch service route to ocloud2 is sent from O-Cloud Node to SMO. A decision 'Switch service route to ocloud2 and terminate VNF/App instance on ocloud2' follows. A loop '[for each VNF/Apps]' contains 6.1 Request to terminate the VNF/App sent from SMO to O-Cloud Node. An alt block '[ETSI]' contains 'ETSI o-cloud terminate VNF/Apps'. Another alt block '[K8s (Kubernetes) ]' contains 'K8s (Kubernetes) o-cloud terminate'. 6.2 Response to indicate the result of VNF/App termination is sent from O-Cloud Node to SMO. 7. Response to indicate VNF/App node changing success is sent from SMO to Orchestrator.](568ae4aa06916d9a53d78193fcf540e7_img.jpg) + +Sequence diagram showing the process of redeploying a computing task based on performance information reporting. The diagram involves four main entities: Orchestrator, SMO, IMS/DMS, and O-Cloud Node (Node 1, Node 2...Node N). The process starts with a 'VNF/Apps performance Subscription' event. 1. Orchestrator sends 'Subscription of VNF/App performance information report periodic or event trigger' to SMO. 2.1 SMO sends 'Subscription of VNF/App performance information report periodic or event trigger' to IMS/DMS. 2.2 SMO sends 'Response of VNF/App performance information' to IMS/DMS. 3. IMS/DMS sends 'Response of VNF/App performance information' to Orchestrator. A loop '[performance data accumulation]' follows. 4.1 or VNF/App performance Information is sent from O-Cloud Node to IMS/DMS. 4.2 or VNF/App performance Information is sent from O-Cloud Node to SMO. 4.3 or VNF/App performance Information is sent from SMO to Orchestrator. 4.4 Notifications to indicate VNF/App performance are sent from Orchestrator to SMO. A decision 'Performance cant fulfill the resource requirement, deploy the VNF/App or App to other Cloud Node' leads to 5.1 Request to change the cloud node to o-Cloud node 2. A loop '[for each NF need to be deployed on o-Cloud node 2]' follows. An alt block '[ETSI]' contains 'ETSI o-cloud Instantiate VNF/Apps refer to WG6 O2DMS ETSI IF 2.4.2.1'. Another alt block '[K8s (Kubernetes) ]' contains 'K8s (Kubernetes) o-cloud instantiate NF deployment refer to WG6 O2DMS Kubernetes IF 3.1.2'. 5.2 Switch service route to ocloud2 is sent from O-Cloud Node to SMO. A decision 'Switch service route to ocloud2 and terminate VNF/App instance on ocloud2' follows. A loop '[for each VNF/Apps]' contains 6.1 Request to terminate the VNF/App sent from SMO to O-Cloud Node. An alt block '[ETSI]' contains 'ETSI o-cloud terminate VNF/Apps'. Another alt block '[K8s (Kubernetes) ]' contains 'K8s (Kubernetes) o-cloud terminate'. 6.2 Response to indicate the result of VNF/App termination is sent from O-Cloud Node to SMO. 7. Response to indicate VNF/App node changing success is sent from SMO to Orchestrator. + +**Table 5.6.3.2-2: Performance information reporting triggers redeployment of a computing task** + +Required data: + +Some computing task performance information that proposed to be exposed is list as below: + +##### 1) K8s + +- K8S pod status: + - Pending + - Running + - Succussed + - Failed + - unknown + +- K8S Node, Pod, containers usage: + - Memory requests: Total memory requests (bytes) of a pod + - Memory limits Total memory limits (bytes) of a pod + - Allocatable memory Total allocatable memory (bytes) of the node + - Memory utilization Total memory in use on a node or pod + - CPU requests Total CPU requests (cores) of a pod + - CPU limits Total CPU limits (cores) of a pod + - Allocatable CPU total allocatable CPU (cores) of the node + - CPU utilization total CPU in use on a node or pod + - Disk utilization total disk space used on a node + +##### 2) ETSI + +- ETSI VNF performance: + - Average virtual CPU usage + - Average virtual memory usage + - Average virtual disk usage + - Input data size (byte) + - Output data size (byte) + - Number of input packets + - Number of output packets + +#### 5.6.3.2 Performance information reporting triggers to scale a computing task + +The orchestrators external to the O-Cloud who responsible for computing resource orchestration can also be triggered to perform Scale-In and Scale-Out by performance information reporting so as to make full use of computing resources. + +The whole procedure is presented in Table 5.6.3.2-1, illustrated by Figure. 5.6.3.2-1. + +**Table 5.6.3.2-1: Performance information reporting triggers to scale a computing task** + +| Use Case Step | Description of the Step | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | Performance information reporting assist scale-in/scale-out of a computing task | +| Actors and Roles | SMO, O-Cloud, orchestrators from other clouds/application server | +| Assumptions |
  • - All relevant functions and components are instantiated.
  • - O2 interface connectivity is established with SMO.
| +| Pre-conditions |
  • - SMO and O-Cloud are instantiated with O2 interface connectivity being established between them.
| +| Begins when | Orchestrators from other clouds or application servers send subscribe VNFs/Apps performance information of O-Cloud. | +| Step 1 (M) | Orchestrators external to the O-Cloud send VNFs/Apps performance information subscription to SMO. | +| Step 2 (M) | SMO subscribe VNFs/Apps performance information from O-Cloud Nodes. | +| Step 3 (M) | SMO response for VNFs/Apps performance information subscription to orchestrators external to the O-Cloud. | +| Step 4 (L) | SMO collect VNF/App performance information via O2/O1 interface and send the notification to indicate VNF/App performance information to orchestrators from other clouds or application servers. | +| Step 5 (M) | Resource can not fulfill the requirement (Scale out) or less resource is needed (Scale in), orchestrators from other clouds or application servers triggers scale action. | +| Step 6 (L) | SMO scale VNF/App via O2 interface. | +| Step 7 (M) | SMO send response of VNF/App scale-out/Scale-in complete. | +| Ends when | Orchestrators from other clouds or application servers get the response. | +| Post Conditions | N/A | + +``` + +@startuml +Skin rose +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 + +Box "Orchestrator" #lightcyan + Participant "Orchestrator" as client +End box + +Box SMO #gold + Participant "SMO" as smo +End box + +Box O_Cloud Node #lightseagreen + Participant "IMS/DMS" as ims #orange + Participant "Node 1" as ocloud1 +End box +autonumber 1 + +activate ocloud1 +== VNFs/Apps performance Subscription == +client ->smo : Subscription of VNF/App performance information\n report +periodic or event trigger +autonumber 2.1 +smo ->ims : Subscription of VNF/App performance information\n report +periodic or event trigger +smo <-ims : Response of VNF/App performance information +autonumber 3 +client <-smo : Response of VNF/App performance information +||| + +``` + +``` + +loop performance data accumulation +autonumber 4.1 + ims <-> ocloud1: <> or <> VNF/App performance Information + ims -> smo: <> or <> VNF/App performance Information +client <- smo: Notifications to indicatee VNF/App performance +end +||| +== Resource can not fulfill the requirement(Scale out) or less resource is needed(Scale in) == +||| +autonumber 5 +client -> smo: Request to scale-out/scale-in VNF/App +loop for each NF need to be scale-out/scale-in on o-Cloud node +autonumber 6.1 +smo ->ims : Request to scale-out/scale-in VNF/App +note over ims, ocloud1: scale-out/scale-in VNF/App +smo <-ims : Reponse VNF/App scale-out/scale-in complete +end +autonumber 7 +client <- smo:Reponse VNF/App scale-out/scale-in complete + +||| +@enduml + +``` + +![Sequence diagram showing the interaction between Orchestrator, SMO, and O-Cloud Node (IMS/DMS, Node 1) for performance reporting and scaling. The diagram is divided into three main sections: Subscription, Performance Data Accumulation, and Scaling. 1. Subscription: Orchestrator sends 'Subscription of VNF/App performance information report periodic or event trigger' to SMO (1). SMO sends 'Subscription of VNF/App performance information report periodic or event trigger' to IMS/DMS (2.1). IMS/DMS sends 'Response of VNF/App performance information' to SMO (2.2). SMO sends 'Response of VNF/App performance information' to Orchestrator (3). 2. Performance Data Accumulation: A loop box labeled '[performance data accumulation]' contains: SMO sends ' or VNF/App performance Information' to Orchestrator (4.3). SMO sends ' or VNF/App performance Information' to IMS/DMS (4.2). IMS/DMS sends ' or VNF/App performance Information' to Node 1 (4.1). 3. Scaling: A box labeled 'Resource can not fulfill the requirement(Scale out) or less resource is needed(Scale in)' triggers: Orchestrator sends 'Request to scale-out/scale-in VNF/App' to SMO (5). A loop box labeled '[for each NF need to be scale-out/scale-in on o-Cloud node]' contains: SMO sends 'Request to scale-out/scale-in VNF/App' to IMS/DMS (6.1). A yellow note box 'scale-out/scale-in VNF/App' is shown over the IMS/DMS and Node 1 lifelines. IMS/DMS sends 'Reponse VNF/App scale-out/scale-in complete' to SMO (6.2). SMO sends 'Reponse VNF/App scale-out/scale-in complete' to Orchestrator (7).](f41528ff107609a04a7cc43aef419d17_img.jpg) + +Sequence diagram showing the interaction between Orchestrator, SMO, and O-Cloud Node (IMS/DMS, Node 1) for performance reporting and scaling. The diagram is divided into three main sections: Subscription, Performance Data Accumulation, and Scaling. 1. Subscription: Orchestrator sends 'Subscription of VNF/App performance information report periodic or event trigger' to SMO (1). SMO sends 'Subscription of VNF/App performance information report periodic or event trigger' to IMS/DMS (2.1). IMS/DMS sends 'Response of VNF/App performance information' to SMO (2.2). SMO sends 'Response of VNF/App performance information' to Orchestrator (3). 2. Performance Data Accumulation: A loop box labeled '[performance data accumulation]' contains: SMO sends ' or VNF/App performance Information' to Orchestrator (4.3). SMO sends ' or VNF/App performance Information' to IMS/DMS (4.2). IMS/DMS sends ' or VNF/App performance Information' to Node 1 (4.1). 3. Scaling: A box labeled 'Resource can not fulfill the requirement(Scale out) or less resource is needed(Scale in)' triggers: Orchestrator sends 'Request to scale-out/scale-in VNF/App' to SMO (5). A loop box labeled '[for each NF need to be scale-out/scale-in on o-Cloud node]' contains: SMO sends 'Request to scale-out/scale-in VNF/App' to IMS/DMS (6.1). A yellow note box 'scale-out/scale-in VNF/App' is shown over the IMS/DMS and Node 1 lifelines. IMS/DMS sends 'Reponse VNF/App scale-out/scale-in complete' to SMO (6.2). SMO sends 'Reponse VNF/App scale-out/scale-in complete' to Orchestrator (7). + +**Figure 5.6.3.2-1: Performance information reporting triggers to scale a computing task** + +Required data: + +Same as clause 5.6.3.1. + +### 5.6.4 Benefits of O-RAN Architecture + +By providing computing task performance information to orchestrators external to the O-Cloud, orchestrators and application servers can redeploy or adjust computing tasks in O-Cloud. O-Cloud's edge computing resources can be fully and accurately scheduled. In that way, edge computing vertical businesses (e.g. XR, AI/ML, V2X, vertical industries) can be effectively supported by computing resource services. + +# --- 6 Key Issues + +## 6.1 Key Issue #1: Joint Communication and Computing Optimization + +Use cases 3, 4, and 5 have a common requirements on the joint communication and computing optimization. Use case 1 investigates the computing aware handover optimization. Use case 3 discusses how to expose the communication and computing status to the external entities (e.g., multi-cloud orchestrator, applications) to enable the RAN aware application optimization. + +In this key issue, the following points need to be studied: + +- How to enhance the mobility management to ensure the connection & service continuity taking both the communication and computing resource status into consideration? +- What information needs to be exposed by O-RAN to external entities? +- Which entity in O-RAN will do the exposure? +- What's the mechanism (including the security mechanism) to support the information exposure? + +## 6.2 Key Issue #2: O-RAN computing service provision + +Use cases 3, 4 and 5 have a common requirement of exposing vacant O-RAN computing capabilities. The radio edge computing capability offered by O-RAN can be discovered by the O-RAN external consumers such as the multi-cloud orchestration or the application servers. The external consumers can monitor the O-RAN computing capability as well as other necessary information to decide whether to request edge application offloading to the O-RAN system. + +In this key issue, the following mechanisms need to be studied: + +- How an external consumer requests or subscribes to O-RAN system for providing the O-RAN computing capabilities? +- How O-RAN system provides/updates the O-RAN computing capabilities to the external consumer? +- How an external consumer requests or subscribes to O-RAN system for offloading the computing tasks to O-RAN system? + +## 6.3 Key Issue #3: O-RAN integrated communication and computing service provision + +Use Cases 3, 4 and 5 in Clause 5 expect O-RAN to provide integrated communication and computing services towards the external consumers (e.g., a multi-cloud orchestrator). Currently, SMO intent driven management was studied in [i.x], where RAN management intent and RAN performance assurance intents were investigated. However, they are all focusing on RAN communication services provision. While key issue1 targets the O-RAN computing service provision. Key issue 3 is built on key issue 2 and the RAN service provision studied in [i.32] [i.33] [i.34], trying to investigate the integrated communication and computing service provision. + +In this key issue, the following mechanisms need to be studied: + +- How to describe or model the integrated communication and computing service profile? +- How an external consumer requests or subscribes to the O-RAN system for integrated communication and computing services? +- How does O-RAN system jointly orchestrate the communication and computing resources to fulfill the service request? + +## 6.4 Key Issue #4: Edge application orchestration in O-RAN + +As stated in use cases 3, 4 and 5, the vacant computing resources from the cloud-based RAN can be leveraged to offload edge computing applications or tasks so that radio cloud resources can be efficiently utilized. To achieve this vision and facilitate the computing service provision, integrated communication and computing services provision discussed in key issue 2 and 3, the edge application lifecycle management, including deployment, termination, upgrade, scale-in and out, etc., needs to be considered within O-RAN. + +In this key issue, the following mechanism needs to be studied: + +- How to deploy, manage and orchestrate the edge applications running on the O-Cloud? +- How the edge application orchestration functionality interacts with the SMO services (SMOS) studied in [i.33], such as the RAN analytics SMOS, service orchestration SMOS, service assurance SMOS, to facilitate the joint communication and computing orchestration? + +# --- 7 Potential Solutions + +## 7.1 Solution #1: O1 configurations for multi-aspect handover optimization + +### 7.1.1 Key Issue Mapping + +This solution is for Key Issue #1: Joint Communication and Computing Optimization, specifically to enhance mobility management to ensure connection and service continuity, taking both communication and computing resource status into consideration. + +### 7.1.2 Description + +The solution is based on the clause 5.1 Use Case 1: Multi aspect handover optimization. It is built based on the existing capabilities of different interfaces such as R1 interface, O1 interface, O2 interface, etc and introduces new O1 based + +configurations in Near-RT RIC to support multi-aspect handover optimization in a Communication and Computing Integrated Networks. + +This solution consists of rApp, SMO/Non-RT RIC Framework, near-RT RIC, E2 nodes, and O-Cloud. rApp uses the R1 interface to retrieve different input data, such as CM data, PM data, location data of different cloud-based RAN entities, supported types of computing resources, capabilities of computing resource types, and load/availability of computing resources in different cloud-based RAN entities. rApp then executes relevant algorithms to derive the proximal computing capability table and availability table for each cloud-based RAN entity. rApp uses this information to create different O1 based configurations for multi-aspect handover optimization using R1 services provided by SMO/Non-RT RIC Framework, which then creates the O1 based configurations at one or more near-RT RIC instances over O1. Near-RT RIC will then use E2 control or E2 policy to ensure the UE handover to the optimum target cloud-based Radio entity. + +### 7.1.3 Procedures + +Figure 7.1.3-1 depicts the procedure summarizing the solution. + +``` +@startuml +Skin rose +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam wrapWidth 300 +autonumber + +box #lightseagreen + participant "O-Cloud(s)" as OLOUDS +endbox + +box #gold + participant "rApp" as rApp + Participant "SMO / Non-RT RIC Framework" as nonRTRICFramework +endbox + +box "O-RAN Nodes" #lightpink + Participant "Near-RT RIC" as NearRTRIC + Participant "E2-Node(s)" as RANNodes +endbox + +group O1 Data Collection + rApp -> nonRTRICFramework : <> Data collection request + nonRTRICFramework -> RANNodes : <> Data collection request + RANNodes -> nonRTRICFramework : <> Data Collection + nonRTRICFramework -> rApp : <> Data Collection +end + +group O2 Data Collection + rApp -> nonRTRICFramework : <> Data collection request + nonRTRICFramework -> OLOUDS : <> Data collection request + OLOUDS -> nonRTRICFramework : <> Data Collection + nonRTRICFramework -> rApp : <> Data Collection +end + +group Data Analysis and Inference + rApp -> rApp : Create Proximal Computing Capability Table and Availability table + for each O-Cloud based RAN nodes and prepare related O1 configurations for multi-aspect + handover optimization. +end +``` + +``` + +end + +group Policy Creation + rApp -> nonRTRICFramework : <> Create O1 configurations for multi-aspect handover optimization + nonRTRICFramework -> NearRTRIC : <> Create O1 configurations + NearRTRIC -> RANNodes : <> E2 control or E2 policies for multi-aspect handover optimization +end + +@enduml + +``` + +![Sequence diagram for O1 configurations for multi-aspect handover optimization. The diagram shows interactions between O-Cloud(s), rApp, SMO/Non-RT RIC Framework, Near-RT RIC, and E2-Node(s). The process is divided into three main sections: O1 Data Collection, O2 Data Collection, and Policy Creation. In O1 Data Collection, rApp sends a request to SMO/Non-RT RIC Framework, which then sends a request to Near-RT RIC, which in turn sends a request to E2-Node(s). Data collection responses flow back. In O2 Data Collection, rApp sends a request to SMO/Non-RT RIC Framework, which sends a request to Near-RT RIC, which then sends a request to E2-Node(s). Data collection responses flow back. In Policy Creation, rApp sends a request to SMO/Non-RT RIC Framework, which sends a request to Near-RT RIC, which then sends a request to E2-Node(s). The final response flows back to rApp.](fa14b4e705b278d763fdb5c79f448d17_img.jpg) + +``` + +sequenceDiagram + participant OCloud as O-Cloud(s) + participant rApp + participant SMO as SMO / Non-RT RIC Framework + participant NearRT as Near-RT RIC + participant E2 as E2-Node(s) + + Note over OCloud, rApp: O1 Data Collection + rApp->>SMO: 1 <> Data collection request + SMO->>NearRT: 2 <> Data collection request + NearRT->>E2: 3 <> Data Collection + E2-->>NearRT: + NearRT-->>SMO: 4 <> Data Collection + SMO-->>rApp: + + Note over OCloud, rApp: O2 Data Collection + rApp->>SMO: 5 <> Data collection request + SMO->>NearRT: 6 <> Data collection request + NearRT->>E2: 7 <> Data Collection + E2-->>NearRT: + NearRT-->>SMO: 8 <> Data Collection + SMO-->>rApp: + + Note over OCloud, rApp: Data Analysis and Inference + rApp->>SMO: 9 Create Proximal Computing Capability Table and Availability table for each O-Cloud based RAN nodes and prepare related O1 configurations for multi-aspect handover optimization. + SMO-->>rApp: + + Note over OCloud, rApp: Policy Creation + rApp->>SMO: 10 <> Create O1 configurations for multi-aspect handover optimization + SMO->>NearRT: 11 <> Create O1 configurations + NearRT->>E2: 12 <> E2 control or E2 policies for multi-aspect handover optimization + E2-->>NearRT: + NearRT-->>SMO: + SMO-->>rApp: + +``` + +Sequence diagram for O1 configurations for multi-aspect handover optimization. The diagram shows interactions between O-Cloud(s), rApp, SMO/Non-RT RIC Framework, Near-RT RIC, and E2-Node(s). The process is divided into three main sections: O1 Data Collection, O2 Data Collection, and Policy Creation. In O1 Data Collection, rApp sends a request to SMO/Non-RT RIC Framework, which then sends a request to Near-RT RIC, which in turn sends a request to E2-Node(s). Data collection responses flow back. In O2 Data Collection, rApp sends a request to SMO/Non-RT RIC Framework, which sends a request to Near-RT RIC, which then sends a request to E2-Node(s). Data collection responses flow back. In Policy Creation, rApp sends a request to SMO/Non-RT RIC Framework, which sends a request to Near-RT RIC, which then sends a request to E2-Node(s). The final response flows back to rApp. + +Figure 7.1.3-1: O1 configurations for multi-aspect handover optimization + +### 7.1.4 Impacts on entities, services and interfaces + +SMO/Non-RT RIC Framework: + +- Collects necessary CM/PM data from different cloud-based RAN entities over O1 interface. Collects supported types of computing resources, capabilities of computing resource types, and load/availability of computing resources in different cloud-based RAN entities over O2 interface. +- Provides CM data, PM data, supported types of computing resources, capabilities of computing resource types, and load/availability of computing resources of different cloud-based RAN entities to rApp over R1 interface. +- Provides O1 configurations to Near-RT RIC via O1 interface based on the request from rApp. + +rApp: + +- Retrieves necessary C/PM data related to different cloud-based RAN entities from SMO/Non-RT RIC Framework. + +- Retrieves supported types of computing resources, capabilities of computing resource types, and load/availability of computing resources in different cloud-based RAN entities from SMO/Non-RT RIC Framework. +- Derives the Proximal Computing Capability Table and Availability Table for each cloud-based RAN entity, use this information to create related O1 configurations to support multi-aspect handover optimization in Near-RT RIC. + +Near-RT RIC: + +- Performs multi-aspect handover optimization based on the O1 configurations received. +- Sends E2 control or E2 policy messages to E2 nodes (O-CU) related to multi-aspect handover optimization. + +E2 node: + +- Supports CM data read requests from SMO over O1 interface. Collect and Report PM data to SMO over O1 interface. +- Supports UE handover related control and/or policy enforcement from near-RT RIC over E2 interface. + +O-Cloud: + +- Supports data requests related to supported types of computing resources, capabilities of computing resource types, and load/availability of computing resources of different cloud-based RAN entities to SMO over O2 interface. + +## 7.2 Solution #2: Computing information exposure via Y1 interface + +### 7.2.1 Key Issue Mapping + +This solution is for KI #1 Joint Communication and Computing Optimization. + +### 7.2.2 Description + +The solution aims to optimize joint communication and computing resources within O-RAN, particularly for use cases 3, 4, and 5. Building upon the existing capabilities of the Y1 interface, which is well-defined in the Y1 Type Definitions (Y1TD) and currently facilitates the exposure of communication information [i.37], this solution aims to extend the interface's functionality to include the exposure of computing information to external entities. + +The implementation of this solution involves defining the data structures and formats for computing information on the Y1 interface without needing to change the protocols or the procedures [i.38]. Besides, since Y1 Termination communicates with Y1 consumers via Y1 interface and exposes RAN analytics information service(s) from Near-RT RIC, Near-RT RIC need to obtain computing information from other O-RAN entities. + +The solution proposes that Near-RT RIC utilizes the O-Cloud Notification APIs to obtain computing information [i.39], which may be computing resources (containing physical and logical resources) or status (e.g., CPU load, network load, and storage consumption) information. + +### 7.2.3 Procedures + +Figure 7.2.3-1 depicts the procedure summarizing the solution. + +``` +@startuml +Skin rose +``` + +``` +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +``` + +``` +Participant "External entities" as entities +Participant "Near-RT RIC" as near +Participant "O-Cloud" as ocloud +``` + +``` +entities -> near: 1 <> Subscribe/ Request computing information +near -> ocloud: 2 Subscribe/ Request computing information via O-Cloud Notification APIs +ocloud -> near: 3 Response/ Notify +near -> entities: 4 <> Response/ Notify +``` + +``` +@enduml +``` + +![Sequence diagram showing the flow of computing information exposure via Y1 interface. The diagram involves three participants: External entities, Near-RT RIC, and O-Cloud. The sequence of messages is: 1. External entities to Near-RT RIC: «Y1» Subscribe/ Request computing information. 2. Near-RT RIC to O-Cloud: Subscribe/ Request computing information via O-Cloud Notification APIs. 3. O-Cloud to Near-RT RIC: Response/ Notify. 4. Near-RT RIC to External entities: «Y1» Response/ Notify.](2f55686c1cfcb3465ce46debce0822a8_img.jpg) + +``` +sequenceDiagram + participant entities as External entities + participant near as Near-RT RIC + participant ocloud as O-Cloud + entities->>near: 1 «Y1» Subscribe/ Request computing information + near->>ocloud: 2 Subscribe/ Request computing information via O-Cloud Notification APIs + ocloud-->>near: 3 Response/ Notify + near-->>entities: 4 «Y1» Response/ Notify +``` + +Sequence diagram showing the flow of computing information exposure via Y1 interface. The diagram involves three participants: External entities, Near-RT RIC, and O-Cloud. The sequence of messages is: 1. External entities to Near-RT RIC: «Y1» Subscribe/ Request computing information. 2. Near-RT RIC to O-Cloud: Subscribe/ Request computing information via O-Cloud Notification APIs. 3. O-Cloud to Near-RT RIC: Response/ Notify. 4. Near-RT RIC to External entities: «Y1» Response/ Notify. + +**Figure 7.2.3-1: Computing Information Exposure via Y1 interface** + +1. External entities subscribe or request computing information from Near-RT RIC via Y1 interface. +2. Near-RT RIC subscribes or requests computing information via O-Cloud Notification APIs. +3. Near-RT RIC receives response or notifications from O-Cloud. +4. External entities receive response or notifications from Near-RT RIC via Y1 interface. + +### 7.2.4 Impacts on entities, services and interfaces + +Near-RT RIC: + +- Supports for receiving computing information subscription or request from external entities. +- Supports the management of computing information processing workflows before exposure. +- Supports subscription or request to O-Cloud via O-Cloud Notification APIs. +- Supports computing information exposure on the Y1 interface. + +O-Cloud: + +- Supports for receiving computing information subscription or request from Near-RT RIC. + +External entities: + +- Supports subscription or request to Near-RT RIC via Y1 interface. + +## 7.3 Solution #3: Computing Service Provisioning + +### 7.3.1 Key Issue Mapping + +The solution is for Key Issue #2: O-RAN computing service provision. + +### 7.3.2 Description + +In clause 5, the use cases 2 to 5 describes the consumers consuming low latency communication and computing services provided by O-RAN via SMO. To facilitate the provisioning of computing services across diverse application scenarios, it is essential to develop a unified service provisioning approach for the SMO. An unified service provisioning approach of SMO will not only expedite O-RAN's ability to cater to varied business contexts and eliminate the complexity of designing different service delivery methods for different scenarios. + +Document [i.31] gives an Service Based Architecture (SBA) of Non-RT RIC, and the logical function Service Management and Exposure (SME) has been defined for Non-RT RIC internal services management, and exposes service to externals, therefore, utilizing SME to provide computing service to externals consumers is a feasible solution. + +This solution proposes to use SME to provide computing services externally. As a prerequisite for offering computing service, computing service firstly needs to be registered with the SME, e.g., RAN edge application orchestrator (REAO) registers computing service to SME. The SME offers service exposure to support external consumers discover computing service. External consumers obtain computing service API information through service discovery and consume computing service with the API. + +### 7.3.3 Procedures + +Figures 7.3.3-1 to 7.3.3-2 illustrate the process that summarizes the solution, wherein REAO serves as the computing service producer capable of registering and deregistering computing services with SME. + +#### 7.3.3.1 Computing service registration and discovery + +In the computing service registration procedure, REAO registers computing service to SME. The registered service could be exposed to external consumers. + +SME needs to provide a service discovery mechanism to enable external consumers to discover the computing service. SME can provide the service API information to external consumers through the service discovery. The service API information may contain the URI, IP address and Port, protocol, protocol number and data format, etc. for consumer consuming the service. + +The whole procedure is presented in Table 7.3.3-1, illustrated by Figure. 7.3.3-1. + +**Table 7.3.3-1: Computing service registration and service discovery** + +| Use Case Stage | Evolution / Specification | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | Computing service is registered with the SME and exposed to external consumers. Consumers can retrieve the computing service API through service discovery. | +| Actors and Roles | SME, REAO, computing service consumers. | +| Assumptions | The REAO inside SMO produces computing service. | +| Step 1 (M) | REAO registers computing services with the SME. The computing service API information may include the URI, IP address, port, protocol, protocol number, data format, etc. | +| Step 2 (M) | SME feeds the computing service registration result, e.g., successful or failure back to REAO | +| Step 3 (M) | Computing service consumers interacts with SME for the computing service discovery. | +| Step 4 (M) | SME feeds the computing service discovery back with service discovery result (e.g., successful, failure), service API, etc. | + +``` + +@startuml +skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +collections "Computing service consumer" as Consumers #LightCyan + +box "Service Management and Orchestration" #Gold + Participant "SME" as SME #LightGray + Collections "REAO" as REAO #LightGray +end box +Autonumber 1 +group "Computing service registration" + REAO -> SME: Computing service registration request + SME -> REAO: Computing service registration response +end +group "Computing service discovery" + Consumers -> SME: Computing service discovery request + SME -> Consumers: Computing service discovery response +end + +@enduml + +``` + +![Sequence diagram illustrating Computing Service Registration and Discovery. The diagram shows two external participants, 'Computing service consumer' (light blue), and a large yellow box representing 'Service Management and Orchestration'. Inside this box are two participants: 'SME' (light gray) and 'REAO' (light gray). The process is divided into two main groups: 'Computing service registration' and 'Computing service discovery'. In the registration group, REAO sends a '1 Computing service registration request' to SME, and SME returns a '2 Computing service registration response' to REAO. In the discovery group, a 'Computing service consumer' sends a '3 Computing service discovery request' to SME, and SME returns a '4 Computing service discovery response' to the consumer.](a694aeeeea0de5a468ae2a2c8b136d00_img.jpg) + +``` + +sequenceDiagram + participant Consumer as Computing service consumer + participant SME + participant REAO + + note over SME, REAO: "Computing service registration" + REAO->>SME: 1 Computing service registration request + SME-->>REAO: 2 Computing service registration response + + note over Consumer, SME: "Computing service discovery" + Consumer->>SME: 3 Computing service discovery request + SME-->>Consumer: 4 Computing service discovery response + +``` + +Sequence diagram illustrating Computing Service Registration and Discovery. The diagram shows two external participants, 'Computing service consumer' (light blue), and a large yellow box representing 'Service Management and Orchestration'. Inside this box are two participants: 'SME' (light gray) and 'REAO' (light gray). The process is divided into two main groups: 'Computing service registration' and 'Computing service discovery'. In the registration group, REAO sends a '1 Computing service registration request' to SME, and SME returns a '2 Computing service registration response' to REAO. In the discovery group, a 'Computing service consumer' sends a '3 Computing service discovery request' to SME, and SME returns a '4 Computing service discovery response' to the consumer. + +**Figure 7.3.3-1: Computing Service Registration and Discovery** + +#### 7.3.3.2 Computing service consumption + +In the computing service consumption procedure, consumers consume the computing service with the API retrieved from the service discovery procedure. The consumer provides the service requirements (e.g., required computing resource type, computing resource quantity, e2e latency, image URL, etc.) with in the computing service request, REAO allocates computing resources according to the requirements, deploys the workload and provides the consumer service endpoint information. + +The whole procedure is presented in Table 7.3.3-2, illustrated by Figure. 7.3.3-2. + +**Table 7.3.3-2: Computing service consumption** + +| Use Case Stage | Evolution / Specification | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | REAO deploys workloads on the O-Cloud based on user requirements, enabling users to access workloads. | +| Actors and Roles | REAO, O-Cloud, computing service consumers. | +| Assumptions | The REAO inside SMO produces computing service. | +| Step 1 (M) | Consumers request computing service to REAO. Computing service requirement may includes computing resource type (e.g., CPU, GPU, etc.), computing resource quantity, e2e latency, image URL, etc. | +| Step 2 (M) | REAO feeds consumer back with a response to the received computing service request. | +| Step 3 (M) | REAO deploys the workload on O-Cloud according to the computing requirements. | +| Step 4 (M) | Once the workload deployed, REAO notifies consumer with the service availability and service entry point. | +| Step 5 (M) | Consumer accesses the deployed workload. | + +``` + +@startuml +skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +collections "Computing service consumer" as Consumers #LightCyan + +box "Service Management and Orchestration" #Gold + Participant "REAO" as REAO #LightGray +end box + +box "O-Cloud" #DarkCyan + Collections "WorkLoad" as WLoad +end box + +Autonumber 1 + +group "Computing service request" + Consumers -> REAO: Computing service request + REAO -> Consumers: Computing service response +end + +group "Workload deployment" + REAO <-> WLoad**: "Workload deployment" +end + +REAO -> Consumers: Notification, contains e.g., \n service endpoint, service availability, etc. +Consumers <--> WLoad: Service serving + +``` + +@endum1 + +![Sequence diagram for Computing Service Consumption. The diagram shows three main components: Computing service consumer, Service Management and Orchestration (SMO), and O-Cloud. The SMO component contains a REAO (Resource Allocation and Orchestration) entity. The O-Cloud component contains a WorkLoad entity. The sequence of events is: 1. Computing service request (from consumer to SMO), 2. Computing service response (from SMO to consumer), 3. Workload deployment (from SMO to O-Cloud), 4. Notification, contains e.g., service endpoint, service availability, etc. (from SMO to consumer), 5. Service serving (from O-Cloud to consumer).](572c6760222830131acd0f5d2f096b87_img.jpg) + +``` + +sequenceDiagram + participant Consumer as Computing service consumer + participant SMO as Service Management and Orchestration + participant REAO as REAO + participant OCloud as O-Cloud + participant WorkLoad as WorkLoad + + Note over Consumer, SMO: "Computing service request" + Consumer->>SMO: 1 Computing service request + SMO-->>Consumer: 2 Computing service response + Note over SMO, OCloud: "Workload deployment" + SMO->>OCloud: 3 "Workload deployment" + SMO-->>Consumer: 4 Notification, contains e.g., service endpoint, service availability, etc. + OCloud-->>Consumer: 5 Service serving + +``` + +Sequence diagram for Computing Service Consumption. The diagram shows three main components: Computing service consumer, Service Management and Orchestration (SMO), and O-Cloud. The SMO component contains a REAO (Resource Allocation and Orchestration) entity. The O-Cloud component contains a WorkLoad entity. The sequence of events is: 1. Computing service request (from consumer to SMO), 2. Computing service response (from SMO to consumer), 3. Workload deployment (from SMO to O-Cloud), 4. Notification, contains e.g., service endpoint, service availability, etc. (from SMO to consumer), 5. Service serving (from O-Cloud to consumer). + +Figure 7.3.3-2: Computing Service Consumption + +### 7.3.4 Impacts on entities, services and interfaces + +SMO functionality: + +- Introduces new functionality or reuse such as NFO to provide computing service. +- SME functions: + - Support SMOS producer e.g., computing service producer REAO registering computing service to SME. + - Support SMOS producer e.g., computing service producer REAO deregistering computing service from SME. + - Support SMOS producer e.g., computing service producer REAO updating computing service to SME. + - Support computing service exposure to external consumers. + - Support external consumers to discover computing service. + +New service provided by SMO: + +- computing service. + +## 7.4 Solution #4: Integrated communication & computing service provisioning via SMO + +### 7.4.1 Key Issue Mapping + +This solution is for KI #3 O-RAN integrated communication and computing service provision. + +### 7.4.2 Description + +The solution aims to provide integrated communication and computing services towards the external consumers (e.g., a multi-cloud orchestrator) with O-RAN, particularly for use cases AI, XR, and V2X. Based on the existing research of SMO-enabled RAN communication service provisioning and its capability in retrieving the communication and computing resources information, this solution aims to extend the SMO's function to provide integrated communication and computing services. + +This solution involves illustrating the procedure of integrated communication and computing service request, as well as the orchestration of joint communication and computing resources within O-RAN. + +### 7.4.3 Procedures + +The whole procedure is presented in Table 7.4.3-1, illustrated by Figure. 7.4.3-1. + +**Table 7.4.3-1: Integrated communication & computing service provision via SMO** + +| Use Case Stage | Evolution / Specification | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | Provide integrated communication and computing service via SMO | +| Actors and Roles | SMO, Near-RT RIC, O-Cloud, O-CU, O-DU | +| Assumptions | All relevant functions and components are instantiated. | +| Step 1-3 (M) | SMO exposes the integrated communication and computing service, and consumers send requests to SMO, where the service request includes but not limited to following information:
Service profile ID
Maximum number of UEs
Coverage for communication part of communication and computing services provided by RAN
Location of UE
Service end-to-end latency requirements
UE mobility level, UE trajectory
Overall uplink/downlink throughput requirements
Uplink/downlink throughput requirements per UE
Computing resource requirement
Storage resource requirement | +| Step 4-5 (M) | SMO retrieves communication and computing information via O1 and O2 interfaces and performs joint communication and computing resource optimization via AI/ML inference. | +| Step 6-8 (M) | SMO sends the workload deployment policy (e.g., the assigned endpoint) and/or computing resource optimization policy to O-Cloud via the O2 interface; O-Cloud performs workload deployment and resource assignment based on the policy. SMO sends the communication resource optimization policy to Near-RT RIC via A1 interface, and Near-RT RIC send the policy to the E2 node. Also, Near-RT RIC can perform further communication optimization. E2 node allocates the communication (e.g., bandwidth) for services. | +| Step 9 (M) | SMO sends notifications (e.g., service availability) to the consumer. The consumer establishes connection with the assigned endpoint and sends service load to the endpoint. | +| Step 10 (M) | SMO evaluates the performance (e.g., network performance, QoS of service), updates AI/ML model and /or policy accordingly. | + +``` +@startuml +skin rose +skinparam defaultFontSize 12 +Autonumber + +Participant "Service consumer" as consumer +``` + +``` + +Participant "SMO" as SMO +Participant "Near RT-RIC" as RIC +Participant "O-Cloud" as cloud +Participant "E2 nodes" as e2 + +group service exposure +consumer->SMO: service discovery request +consumer<-SMO: service discovery response +end + +consumer->SMO: service request + +group Joint communication and computing resource optimization +SMO<-cloud: Computing resource information +SMO<-e2: Communication resource information +ref over SMO +AI/ML inference +end ref +SMO->cloud: Workload offload policy and/or computing resource optimization policy +SMO->RIC: Communication resource optimization policy +RIC->e2: Communication resource optimization policy +end +consumer<-SMO:Notifications (e.g., service availability) +group Performance monitoring +ref over SMO,RIC,cloud, e2 +Performance monitoring and evaluation +end ref +SMO->SMO: AI/ML model or policy update +end +@enduml + +``` + +![Sequence diagram illustrating the integrated communication and computing service via SMO. The diagram shows the interactions between a Service consumer, SMO, Near RT-RIC, O-Cloud, and E2 nodes. The process starts with a service exposure phase where the consumer sends a service discovery request and receives a response, then sends a service request. This is followed by a joint communication and computing resource optimization phase where the SMO receives information from the O-Cloud and E2 nodes, performs AI/ML inference, and sends policies back to the O-Cloud, Near RT-RIC, and E2 nodes. Finally, the SMO sends notifications to the consumer and performs performance monitoring and evaluation, including an AI/ML model or policy update.](ba1036b393a62afcbf27d9abf2d17312_img.jpg) + +``` + +sequenceDiagram + participant SC as Service consumer + participant SMO + participant Near RT-RIC + participant O-Cloud + participant E2 nodes + + SC->>SMO: 1 service discovery request + SMO-->SC: 2 service discovery response + SC->>SMO: 3 service request + + SMO-<-O-Cloud: 4 Computing resource information + SMO-<-E2 nodes: 5 Communication resource information + SMO->>ref: AI/ML inference + SMO->O-Cloud: 6 Workload offload policy and/or computing resource optimization policy + SMO->Near RT-RIC: 7 Communication resource optimization policy + SMO->E2 nodes: 8 Communication resource optimization policy + + SMO->>SC: 9 Notifications (e.g., service availability) + + SMO->>ref: Performance monitoring and evaluation + SMO->>ref: 10 AI/ML model or policy update + +``` + +Sequence diagram illustrating the integrated communication and computing service via SMO. The diagram shows the interactions between a Service consumer, SMO, Near RT-RIC, O-Cloud, and E2 nodes. The process starts with a service exposure phase where the consumer sends a service discovery request and receives a response, then sends a service request. This is followed by a joint communication and computing resource optimization phase where the SMO receives information from the O-Cloud and E2 nodes, performs AI/ML inference, and sends policies back to the O-Cloud, Near RT-RIC, and E2 nodes. Finally, the SMO sends notifications to the consumer and performs performance monitoring and evaluation, including an AI/ML model or policy update. + +Figure 7.4.3-1: Integrated communication and computing service via SMO + +### 7.4.4 Impacts on entities, services and interfaces + +SMO: + +- Supports integrated communication and computing service exposure. +- Supports receiving integrated communication and computing service requests from external entities. +- Supports joint optimization of communication and computing resources. +- Manages communication and computing information. + +New service provided by SMO: + +- Integrated communication and computing service. + +# --- 8 Analysis on the Potential Architecture Impacts + +Based on the use cases study and potential solutions discussed above, the following potential impacts are identified for the O-RAN architecture. + +## Potential SMO Impact + +- Exposure of the O-RAN computing resource information +- Exposure of the Computing services, and integrated communication and computing services +- New functionality or enhancement on existing SMO functionality to enable the deployment, management and orchestration of the applications running on the O-Cloud +- New functionality or enhancement on existing SMO functionality to facilitate the joint communication and computing orchestration + +## Potential Near-RT RIC Impact + +- Exposure of the O-RAN communication and computing information +- New functionality or enhancement on existing functionality to facilitate the computing aware handover optimization + +## Potential O-Cloud Impact + +- Orchestration and management of the application deployment' s life cycle +- Management of the heterogeneous hardware infrastructure for diversified applications, e.g., AI, XR rendering + +## Potential Impacts on rApps + +- Derive proximal computing availability for O-RAN entity based on the load/availability analysis of the computing resource types + +## Potential O1 Impact + +- O1 configurations for handover based on the proximal computing capability and availability + +# 9 Deployment Scenarios + +## 9.1 Scenario A: Local O-Cloud for private networks + +In this scenario, the Near-RT RIC, O-CU, O-DU functions, and edge applications are all deployed on the same local O-Cloud platform as shown in Figure 9.1-1. This scenario support deployments in the industry private networks, where the edge applications, e.g., industry vision detection application can be deployed together with the 5G network to reduce the service latency and the transport bandwidth from the edge to the central cloud. In this scenario, the mobile network operator can provide the entire enterprise 5G network and edge solution. The mobile operator can choose to partner with one or more industry-specific edge application/platform provider, to deliver the end-to-end services including the 5G connection and the edge cloud capabilities. In this case, the mobile network operator can run the O-RAN NFs as well as the edge applications on its own infrastructure, i.e., O-Cloud. The O-RAN network functions and the edge applications are managed and orchestrated by the SMO. The application service providers (ASPs) may consume the services provided by SMO to orchestrate and manage the edge applications. + +![Figure 9.1-1: Deployment Scenario A. This block diagram illustrates the architecture of Scenario A. At the top, an ASP (Application Service Provider) is connected to the SMO (Service Management and Orchestration) block. The SMO is connected to the O-Cloud Platform via an O2 interface. The O-Cloud Platform contains several components: Near-RT RIC, O-CU (Control Unit), O-DU (Distributed Unit), and Edge Applications. The Near-RT RIC is connected to the O-CU via an E2 interface and to the O-DU via an F1 interface. The O-CU is connected to the O-DU via an F1 interface. The O-CU is also connected to a Local UPF (User Plane Function) block, which is connected to the Edge Applications. The Edge Applications are connected to the O-Cloud Platform via a Y1 interface. The O-Cloud Platform is connected to the O-RU (Radio Unit) via an Open Fronthaul interface.](ec5d4651d3468674c02d75ee19c26088_img.jpg) + +Figure 9.1-1: Deployment Scenario A. This block diagram illustrates the architecture of Scenario A. At the top, an ASP (Application Service Provider) is connected to the SMO (Service Management and Orchestration) block. The SMO is connected to the O-Cloud Platform via an O2 interface. The O-Cloud Platform contains several components: Near-RT RIC, O-CU (Control Unit), O-DU (Distributed Unit), and Edge Applications. The Near-RT RIC is connected to the O-CU via an E2 interface and to the O-DU via an F1 interface. The O-CU is connected to the O-DU via an F1 interface. The O-CU is also connected to a Local UPF (User Plane Function) block, which is connected to the Edge Applications. The Edge Applications are connected to the O-Cloud Platform via a Y1 interface. The O-Cloud Platform is connected to the O-RU (Radio Unit) via an Open Fronthaul interface. + +**Figure 9.1-1: Deployment Scenario A** + +NOTE: UPF is out of O-RAN Scope. + +## 9.2 Scenario B: Device Edge Cloud and local O-Cloud for private networks + +In this scenario, similar to scenario A, the Near-RT RIC, O-CU, O-DU functions, and edge applications are all deployed on the same local O-Cloud platform. Furthermore, the 5G industry gateway is introduced and serves as device edge cloud. The mobile operator can choose to partner with one or more industry-specific edge application/platform, device edge application provider, to deliver the end-to-end services including the 5G connection, the edge cloud capabilities and the device edge cloud capabilities. The SMO can be extended to also manage and orchestrate the device edge cloud and the device edge applications compared to scenario A. The deployment scenario is shown in Figure 9.2-1. + +![Figure 9.2-1: Deployment Scenario B. This diagram shows a network architecture where a 5G Industry Gateway (containing Device, Edge Applications, and Device Edge Cloud) connects via Uu to an O-RU. The O-RU connects via Open Fronthaul to an O-Cloud Platform. Inside the O-Cloud Platform, there is a Near-RT RIC (connected to the O-RU via E2), an O-CU (connected to the Near-RT RIC via E2 and to the O-DU via F1), and an O-DU. The Near-RT RIC is also connected to a Local UPF and Edge Applications via Y1. The SMO (Service Management and Orchestration) is connected to the ASP (Application Service Provider) and the O-Cloud Platform via O2. The SMO also has a direct connection to the 5G Industry Gateway.](83c8021ecb72f2b421ed610410494784_img.jpg) + +Figure 9.2-1: Deployment Scenario B. This diagram shows a network architecture where a 5G Industry Gateway (containing Device, Edge Applications, and Device Edge Cloud) connects via Uu to an O-RU. The O-RU connects via Open Fronthaul to an O-Cloud Platform. Inside the O-Cloud Platform, there is a Near-RT RIC (connected to the O-RU via E2), an O-CU (connected to the Near-RT RIC via E2 and to the O-DU via F1), and an O-DU. The Near-RT RIC is also connected to a Local UPF and Edge Applications via Y1. The SMO (Service Management and Orchestration) is connected to the ASP (Application Service Provider) and the O-Cloud Platform via O2. The SMO also has a direct connection to the 5G Industry Gateway. + +**Figure 9.2-1: Deployment Scenario B** + +## 9.3 Scenario C: O-Cloud coordination with global orchestrator + +In this scenario, the Near-RT RIC network function is deployed on a regional cloud platform, While the O-CU and O-DU functions are deployed on an edge cloud platform that in a different location of the Near-RT RIC. Near-RT RIC can control multiple O-CUs and O-DUs and is centralized for RAN optimization based on a more global view. The deployment scenario is shown in Figure 9.3-1. SMO can manage and orchestrate the cloud infrastructure that holds both the Near-RT RIC, O-CU and O-DU. Moreover, the computing capability of the infrastructure can be exposed by SMO to the global orchestrator. So the global orchestrator can request to deploy the edge applications on the O-Cloud platform as needed. + +![Figure 9.3 -1: Deployment Scenario C. This diagram shows a network architecture where a Global Orchestrator is connected to the SMO (Service Management and Orchestration) via O2. The SMO is connected to an O-Cloud Platform. Inside the O-Cloud Platform, there is a Near-RT RIC (connected to the SMO via O2), an O-CU (connected to the Near-RT RIC via E2 and to the O-DU via F1), and an O-DU. The Near-RT RIC is also connected to a Local UPF and Edge Applications via Y1. The O-Cloud Platform is also connected to a Central Cloud & Applications block via O2. The O-Cloud Platform is also connected to an O-RU via Open Fronthaul.](e9b19bd9e1a1e5ae3e7f89383efdbccd_img.jpg) + +Figure 9.3 -1: Deployment Scenario C. This diagram shows a network architecture where a Global Orchestrator is connected to the SMO (Service Management and Orchestration) via O2. The SMO is connected to an O-Cloud Platform. Inside the O-Cloud Platform, there is a Near-RT RIC (connected to the SMO via O2), an O-CU (connected to the Near-RT RIC via E2 and to the O-DU via F1), and an O-DU. The Near-RT RIC is also connected to a Local UPF and Edge Applications via Y1. The O-Cloud Platform is also connected to a Central Cloud & Applications block via O2. The O-Cloud Platform is also connected to an O-RU via Open Fronthaul. + +**Figure 9.3 -1: Deployment Scenario C** + +# 10 Potential Requirements + +| | Description | +|---------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REQ-SMO-01 | The SMO should support the capability to expose O-RAN computing resource information to authorized SMO services consumers. | +| REQ-SMO-02 | The SMO should expose the RAN computing services to authorized SMO services consumers. | +| REQ-SMO-03 | The SMO should expose the RAN integrated communication and computing services to authorized SMO services consumers. | +| REQ-SMO-04 | The SMO should provide discoverability of the RAN computing capabilities offered by the SMO to authorized SMO services consumers. | +| REQ-SMO-05 | The SMO should provide discoverability of the RAN integrated communication and computing capabilities offered by the SMO to authorized SMO services consumers. | +| REQ-SMO-06 | The SMO should support the capabilities to jointly orchestrate the communication and computing resources of the O-Cloud and functionalities running over the O-Cloud . | +| REQ-SMO-07 | The SMO should support the capabilities to deploy, manage and orchestrate the applications running on the O-Cloud. | +| REQ-RIC-01 | The Near-RT RIC should support the capability to expose the O-RAN communication and computing analytics information. | +| REQ-RIC-02 | The Near-RT RIC should support the computing aware handover optimization. | +| REQ-OCLOUD-01 | The O-Cloud should support the orchestration and management of the application deployment's life cycle. | +| REQ-OCLOUD-02 | The O-Cloud should support the management of heterogeneous hardware infrastructure for diversified applications, e.g., AI, XR rendering. | +| REQ-O1-01 | The O1 interface should support the capability of transferring the O1 configurations for handover proximal computing capability and availability. | +| REQ-HRD-01 | The hardware reference design for O-RAN should support heterogeneous computing for O-RAN network functions and diversified applications, e.g., edge AI, XR rendering. | + +# 11 Conclusion and Recommendations + +This Technical Report presents the use cases for integrated communication and computing in O-RAN. The potential solutions are also studied for the identified use cases and key issues. + +It is recommended to continue the study and specify the well identified use cases, the necessary architecture requirements and enhancements during normative work. + +# --- Annex: Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.07.28 | 01.00 | Version incremented for TSC. | +| 2024.07.28 | 00.00.10 | Editorial changes according to the review comments during WG1 poll. | +| 2024.07.12 | 00.00.09 | Implemented CRs
  • - CMCC-2024.07.04-WG1-UCTG-CR-0027-Potential Requirements for CCIN-v01.docx
  • - CMCC-2024.07.04-WG1-UCTG-CR-0028-Add Conclusion and Recommendations for CCIN-v02.docx
Remove the optional Executive summary, introduction and the blank Annex A, Annex B | +| 2024.07.11 | 00.00.08 | Implemented CRs
  • - CMCC-2024.04.26-WG1-UCTG-CR-0019-Potential solution for CCIN TR key issue 1-v03.docx
  • - CMCC-2024.04.17-ORAN-UCTG-CR-0020-addPotentialSoulutionfor KeyIssue2_v02.docx
  • - CMCC-2024.04.01-ORAN-UCTG-CR-0021UseCase-AddProposedSolution4MobileDeviceandRANAIInferenceCollaboration_v02.docx
  • - CMCC-2024.05.30-WG1-UCTG-CR-0022-Potential solution 3 for CCIN TR-v03.docx
  • - CMCC-2024.06.03-WG1-UCTG-CR-0023-Analysis on Potential Architecture Impacts of CCIN-v05.docx
  • - CMCC-2024.06.03-WG1-UCTG-CR-0024-Deployment Scenarios for CCIN-v02.docx
  • - CMCC-2024.06.03-WG1-UCTG-CR-0025-Potential Requirements for CCIN-v03.docx
Editorial corrections | +| 2024.06.18 | 00.00.07 | Implemented CR
  • - NOK-2024-06-09-WG1-UCTG-CR-0067-CCIN TR-Solution based on multi-aspect-handover-optimization-v02.docx
| +| 2024.06.04 | 00.00.06 | Implemented CRs
  • - CICT-2024.04.18-WG1-UCTG-CCIN-CR-0001-TR-Exposure of Performance information-v02.docx
| +| 2024.05.06 | 00.00.05 | Implemented CRs
  • - CMCC-2024.03.21-WG1-UCTG-CR-0015-add key issue 1 for CCIN TR clause 6-v02.docx
  • - CMCC-2024.03.21-WG1-UCTG-CR-0016-add key issue 2 for CCIN TR clause 6-v02.docx
  • - CMCC-2024.03.21-WG1-UCTG-CR-0017-add key issue 3 for CCIN TR clause 6-v02.docx
  • - CMCC-2024.03.21-WG1-UCTG-CR-0018-add key issue 4 for CCIN TR clause 6-v02.docx
| +| 2024.03.30 | 00.00.04 | Implemented CRs
  • - CMCC-2023.10.11-ORAN-UCTG-CR-0008UseCase MobileDeviceandRANAIInferenceCollaboration_v04.docx
  • - CMCC-2024.01.18-WG1-UCTG-CR-0010-CCIN-add XR rendering collaboration use case for clause 5_v04.docx
  • - CMCC-2024.03.21-WG1-UCTG-CR-0011-CCIN- add V2X communications use case for clause 5_v06.docx
| +| 2024.03.21 | 00.00.03 | Implemented CRs
  • - CMCC-2024.02.13-WG1-UCTG-CR-0012-add O-RAN related work for CCIN TR clause 4.2-v01.docx
  • - CMCC-2024.02.13-WG1-UCTG-CR-0013-add O-RAN related work for CCIN TR clause 4.3-v01.docx
  • - CMCC-2024.03.07-ORAN-UCTG-CR-0014 CCIN phases and general challenges v3.docx
| + +| | | | +|------------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.02.13 | 00.00.02 |

Implemented CRs

  • - CMCC-2023.10.09-WG1-UCTG-CR-0001-add scope description for CCIN TR clause 1 - v02.docx
  • - NOK.AO-2023-10-11-WG1-CR-0001-CCIN TR-Multi aspect handover optimization-v02.docx
  • - CMCC-2023.10.09-WG1-UCTG-CR-0002-add text for CCIN TR clause 4.1-v02.docx
  • - CMCC-2023.10.09-WG1-UCTG-CR-0003-add NFV related work for CCIN TR clause 4.1-v02.docx
  • - CMCC-2023.10.09-WG1-UCTG-CR-0004-add MEC related work in ETSI for CCIN TR clause 4.1-v02.docx
  • - CMCC-2023.10.09-WG1-UCTG-CR-0005-add Edge Computing related work in 3GPP for CCIN TR clause 4.1-v02.docx
  • - CMCC-2023.10.09-WG1-UCTG-CR-0006-add coordination of computing and networking related work in ITU-T for CCIN TR clause 4.1-v02.docx
  • - CMCC-2023.10.09-WG1-UCTG-CR-0007-add computing aware traffic steering related work in IETF for CCIN TR clause 4.1-v02.docx
  • - CMCC-2023.10.11-ORAN-CCIN-CR-0009 UseCase RadioEdgeComputingResourceInformationExposure_v02.docx

apply the latest TR template O-RAN.WGn.descriptor.0-v02.00-TR-template

Editorial corrections

| +| 2023.07.17 | 00.00.01 | Initial TR skeleton | \ No newline at end of file diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/1ded814648b12a19e8ecad609b6840f9_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/1ded814648b12a19e8ecad609b6840f9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f8c10fa326d9bc6921bea1d61c648611e201660c --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/1ded814648b12a19e8ecad609b6840f9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3094f03f7e30782bea7a5f2d71287a56a8d72189c50f777881d816a0c612da2b +size 3652 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/29f9190227c244e2a90c8ca4d717746e_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/29f9190227c244e2a90c8ca4d717746e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7cd9e35aa043f8eea346270fc55f2a8fd5d89c5f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/29f9190227c244e2a90c8ca4d717746e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9290c93bc28c4266b69c59af499300dfdb2a75df79a72baf863052da29cc61b6 +size 107444 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/2ee688bfbd2e5e0ad32087385d3f5dc3_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/2ee688bfbd2e5e0ad32087385d3f5dc3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b31576f028c2f512c91e46965eeed8bbd9ab7d39 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/2ee688bfbd2e5e0ad32087385d3f5dc3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7813ba21797f347b2053c07743ba5229aeb6de1cadb524b9454dc08cc28074fe +size 33551 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/332d5dccded68be966d70964efa88e8f_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/332d5dccded68be966d70964efa88e8f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1b0d97ac86282aa5524d7716458a6abae601af3a --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/332d5dccded68be966d70964efa88e8f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3f77040d067c89e59922a9c93599683f08e7013e1b0c5bf43551f47a5509c4bb +size 3582 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/388928824cf728fa6396032b2bb1726d_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/388928824cf728fa6396032b2bb1726d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e5f3385d861689b44f473e19d1d9a8f411cebc7c --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/388928824cf728fa6396032b2bb1726d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e242327d9090424c97808c16906bc9907396071c1ea380bffecf92d816ab9b7b +size 6119 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/390879f49a2b9895bc017094b7c9bbd5_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/390879f49a2b9895bc017094b7c9bbd5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4209f1ff293497294c62ec307e04a6494a9c7d62 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/390879f49a2b9895bc017094b7c9bbd5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:28bb54e874eea65d23c25a7d732ebc52c1e05252a1fe271b0e5c01e666c8612d +size 33859 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/60605ea537101425c8707efce206435d_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/60605ea537101425c8707efce206435d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..33fb3126c32593f59e980dd7ce0e7a4c37146b60 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/60605ea537101425c8707efce206435d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3cc5ecc98764f645397f41e56161f8ccbedb14951f95af7908fcbb721ab5398e +size 3589 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/7738f85760a347876627087db5eff7d7_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/7738f85760a347876627087db5eff7d7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a394f6269371a3b631cee00fad398a3800ba5688 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/7738f85760a347876627087db5eff7d7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:49caf0b58fb958d12055c87dfdff54f6baf27c6ac1142352b47f3d9c39a9c61d +size 3712 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/7d91e675e0ad8ee304999cde1e541e30_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/7d91e675e0ad8ee304999cde1e541e30_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..49b8ea73a88094ec2424d6db1e68eb701f54baf8 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/7d91e675e0ad8ee304999cde1e541e30_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:58a81977b67f01a4f122c22bed7178bf67a2050fd555e47803143264d49f22fe +size 3652 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/8c654b4c612ee701d8f2d9f11bdbc27a_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/8c654b4c612ee701d8f2d9f11bdbc27a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..223edb101dcec47da8903176903a60d8e3799c24 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/8c654b4c612ee701d8f2d9f11bdbc27a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0c1aa09083ec5bc24db10b5c600dd9f4886b3c50b1c1202810eb568e6e1fd570 +size 111944 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/a592c7d5c73d599f7d643324e6e51284_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/a592c7d5c73d599f7d643324e6e51284_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de8eb48b4f1e5953c7ece059cd87d1af189a02bc --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/a592c7d5c73d599f7d643324e6e51284_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5cdb80506b821a8338b88d1c1c1cd72a5267e82f6404f53c499460701e4f38e7 +size 3533 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/bb690bed8abad3938e821fbb0a45ed7d_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/bb690bed8abad3938e821fbb0a45ed7d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9c08682395a1cc73ea55228ba7d552f76abecc8b --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/bb690bed8abad3938e821fbb0a45ed7d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:14d3697ed80dbe9f974010d614742c37b4661437ff43bf039b0b95c2bcd2ad93 +size 17875 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/de4ddc87c5c4b44287aec4f93581adf9_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/de4ddc87c5c4b44287aec4f93581adf9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..49edcc78429f0414f2ba85a88ba776fd2a26b1c8 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/de4ddc87c5c4b44287aec4f93581adf9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d2ab0168244441dde3f8acf241385b3a67cec187e54563a04016309d14ae0fef +size 90805 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/df6d13ecbe040fdaab04d231ec583591_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/df6d13ecbe040fdaab04d231ec583591_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..039c47ce081da56cce32c0b4dbbc425d941cf4bc --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/df6d13ecbe040fdaab04d231ec583591_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ef7f04fef8bce857dcdb69e6f22641a2d4a87153e4dfe9b52b787989feeaaceb +size 116689 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/f187d3c8a01b9fb3cf20567e63d8d3ff_img.jpg b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/f187d3c8a01b9fb3cf20567e63d8d3ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c251c85d9d8af38776db4fb3225492f0b06062ea --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/f187d3c8a01b9fb3cf20567e63d8d3ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7d2e09b0116f67fbe46e9023f2b226f51d06929cbdf0b64c69f04d0c8c83997 +size 17354 diff --git a/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/raw.md b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..5113774d0b79798fd7497c77b6d2a0c73a0f6fad --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Information Model and Data Models-v01.00/raw.md @@ -0,0 +1,799 @@ + + +# O-RAN Information Model and Data Models Specification --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Information Model and Data Models Specification** --- + +# Contents + +| | | | +|-------------|--------------------------------------------------------------------------------------------------------------------------------|----| +| Chapter 1. | Introductory Material..... | 3 | +| 1.1 | Scope ..... | 3 | +| 1.2 | References..... | 3 | +| 1.2.1 | Definitions and Abbreviations..... | 5 | +| 1.2.2 | Definitions..... | 5 | +| 1.2.3 | Abbreviations and acronyms ..... | 5 | +| Chapter 2. | Overview and Philosophy..... | 7 | +| 2.1 | “Prosumer” relationship between O-RAN and Standards Development Organizations ..... | 7 | +| 2.2 | Information and Data Models as a Modeling Continuum..... | 8 | +| 2.3 | Information and Data Modeling Co-Evolution ..... | 9 | +| 2.4 | Model and Use Case Development (process) ..... | 10 | +| 2.5 | O-RAN components reflected within O-RAN Information Model and Data Model(s)..... | 10 | +| 2.6 | Open Issues and Future Considerations ..... | 11 | +| Chapter 3. | O-RAN Information Model ..... | 12 | +| 3.1 | A general view of an Information Model..... | 12 | +| 3.2 | Modeling approach, Unified Modeling Language (UML)..... | 12 | +| 3.3 | IISOMI (Informal Inter-SDO Open Model Initiative) guidelines..... | 12 | +| 3.4 | General Information on the UML Model..... | 13 | +| 3.5 | O-RAN Information Model ..... | 13 | +| 3.6 | Classes/components and interfaces that comprise the O-RAN Information Model and Data Models..... | 13 | +| 3.7 | Installing and using Papyrus ..... | 14 | +| Chapter 4. | O-RAN Data Models ..... | 15 | +| 4.1 | Repositories; current conventions to distinguish between models under development versus models that are approved for use..... | 15 | +| 4.2 | Formal relationship (traceability) between O-RAN Data Models and the O-RAN Information Model..... | 16 | +| 4.3 | Usage of 3GPP Data Models ..... | 17 | +| 4.4 | Usage of non-3GPP data models ..... | 18 | +| 4.5 | YANG Conventions..... | 21 | +| 4.5.1 | Naming..... | 21 | +| 4.5.2 | Revision Statement..... | 21 | +| 4.5.3 | Indents..... | 22 | +| 4.5.4 | YANG Language Usage..... | 22 | +| 4.5.5 | Cross Working Group Co-ordination ..... | 22 | +| Annex A: | Link to Information Model source (under development; not approved for use) ..... | 23 | +| Annex B: | Installing and using Eclipse Papyrus [refer to O-RAN wiki for the most up-to-date guidelines] ..... | 24 | +| Annex C: | Links to Data Models approved for use..... | 28 | +| Annex ZZZ : | O-RAN Adopter License Agreement..... | 29 | +| Section 1: | DEFINITIONS ..... | 29 | +| Section 2: | COPYRIGHT LICENSE ..... | 29 | +| Section 3: | FRAND LICENSE ..... | 29 | +| Section 4: | TERM AND TERMINATION ..... | 30 | +| Section 5: | CONFIDENTIALITY ..... | 30 | +| Section 6: | INDEMNIFICATION ..... | 30 | +| Section 7: | LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 30 | +| Section 8: | ASSIGNMENT ..... | 31 | +| Section 9: | THIRD-PARTY BENEFICIARY RIGHTS ..... | 31 | +| Section 10: | BINDING ON AFFILIATES ..... | 31 | +| Section 11: | GENERAL..... | 31 | + +# Chapter 1. Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG1 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +**This document is both a Specification and an Informational Report in that it specifies the Information Model (not yet approved for use) and the Data Models (approved for use) that are foundational for O-RAN's model-driven architecture and for the functions carried out over O-RAN interfaces, e.g., management functions, procedures, operations and corresponding solutions.** + +**In addition, this document includes information about existing standards and industry work that serve as a basis for work items in O-RAN. There is a "prosumer" relationship evolving between O-RAN and 3GPP, as each makes its model available and provides model feedback to the other.** + +**Lastly, this document describes the de facto methods and procedures with respect to a "modeling continuum" that aims to establish and evolve an O-RAN Information Model from which O-RAN Data Models may be generated manually or with a set of tools.** + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 16 + +- [1] 3GPP TR 21.905: Vocabulary for 3GPP Specifications +- [2] 3GPP TR 28.890: Management and orchestration; Study on integration of Open Network Automation Platform (ONAP) and 3GPP management for 5G networks +- [3] 3GPP TS 28.530: "Management and orchestration; Concepts, use cases and requirements" +- [4] 3GPP TS 28.531: Management and orchestration; Provisioning +- [5] 3GPP TS 28.532: Management and orchestration; Generic management services +- [6] 3GPP TS 28.533: Management and orchestration: Architecture framework +- [7] 3GPP TS 28.540: Management and orchestration; 5G Network Resource Model (NRM); Stage 1 +- [8] 3GPP TS 28.541: Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3 +- [9] 3GPP TS 28.545: Management and orchestration; Fault Supervision (FS) + +- [10] 3GPP TS 28.550: Management and orchestration; Performance assurance +- [11] 3GPP TS 28.552: Management and orchestration; 5G performance measurements +- [12] 3GPP TS 28.554: Management and orchestration; 5G end to end Key Performance Indicators (KPI) +- [13] 3GPP TS 28.621: Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Requirements +- [14] 3GPP TS 28.622: Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS) +- [15] 3GPP TS 32.341: Telecommunication management; File Transfer (FT) Integration Reference Point (IRP); Requirements +- [16] 3GPP TS 32.342: Telecommunication management; File Transfer (FT) Integration Reference Point (IRP); Information Service (IS) +- [17] 3GPP TS 32.346: Telecommunication management; File Transfer (FT) Integration Reference Point (IRP); Solution Set (SS) definitions +- [18] 3GPP TS 32.421: Telecommunication management; Subscriber and equipment trace; Trace concepts and requirements +- [19] 3GPP TS 32.422: Telecommunication management; Subscriber and equipment trace; Trace control and configuration management +- [20] 3GPP TS 32.423: Telecommunication management; Subscriber and equipment trace; Trace data definition and management +- [21] 3GPP TS 32.508: Telecommunication management; Procedure flows for multi-vendor plug-and-play eNode B connection to the network +- [22] 3GPP TS 32.509: Telecommunication management; Data formats for multi-vendor plug and play eNode B connection to the network +- [23] 3GPP TS 38.401: NG-RAN; Architecture description +- [24] O-RAN-WG4.MP.0-v05.00: O-RAN Alliance Working Group 4 Management Plane Specification +- [25] O-RAN WG1 OAM Architecture v03.00 +- [26] RFC 6241, “Network Configuration Protocol (NETCONF)”, IETF, June 2011 +- [27] RFC 7950, “The YANG 1.1 Data Modeling Language”, IETF, August 2016 +- [28] 3GPP TS 32.156: Telecommunication management; Fixed Mobile Convergence (FMC) Model repertoire +- [29] 3GPP TS 32.160: Management and orchestration; Management service template +- [30] ONF TR-514: UML Modeling Guidelines +- [31] ONF TR-515: Papyrus Guidelines +- [32] ONF TR-531: UML to YANG Mapping Guidelines +- [33] O-RAN Information Model (from Eclipse/Papyrus); +- [34] “Modeling, Use Case and Architecture Process,” B.Cheung et al, May 2019, ONAP + +### 1.2.1 Definitions and Abbreviations + +### 1.2.2 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [1]. + +### 1.2.3 Abbreviations and acronyms + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [1]. + +| | | +|-------------|---------------------------------------------------------| +| 3GPP | 3 rd Generation Partnership Project | +| API | Application Programming Interface | +| CR | Change Requests | +| EMS | Element Management System | +| FCAPS | Fault, Configuration, Accounting, Performance, Security | +| IOC | Information Object Class | +| LS | Liaison Statement | +| MANO | Management and Orchestration | +| ME | Managed Element | +| MF | Managed Function | +| MnS | Management Service | +| MO | Managed Object | +| MOC | Managed Object Class | +| MOI | Managed Object Instance | +| NAT | Network Address Translation | +| Near-RT RIC | O-RAN near real time RAN Intelligent Controller | +| NMS | Network Management System | +| Non-RT RIC | O-RAN non real time RAN Intelligent Controller | +| NRM | Network Resource Model | +| O-CU-CP | O-RAN Central Unit – Control Plane. | +| O-CU-UP | O-RAN Central Unit – User Plane | +| O-DU | O-RAN Distributed Unit | +| OMG | Object Management Group | +| O-RAN | Open Radio Access Network | +| O-RU | O-RAN Radio Unit | +| ONAP | Open Network Automation Platform | +| PNF | Physical Network Function | + +| | | | +|---|-----|--------------------------------------------------------------| +| 1 | RAN | Radio Access Network | +| 2 | RRH | Remote Radio Head | +| 3 | SDO | Standards Development Organization | +| 4 | SMO | Service Management and Orchestration (layer) | +| 5 | TR | Technical Report | +| 6 | TS | Technical Specification | +| 7 | UML | Unified Modeling Language | +| 8 | SA5 | Services & System Aspects Working Group 5 Telecom Management | +| 9 | VNF | Virtualized Network Function | + +# Chapter 2. Overview and Philosophy + +## 2.1 “Prosumer” relationship between O-RAN and Standards Development Organizations + +The O-RAN Alliance complements the work of other Standards Development Organizations (SDO): 3GPP, IETF, and IANA are among the primary sources for OAM (Management) specifications for O-RAN components. + +3GPP published its 5G Network Resource Model (Information Model) as well as “Trial - SA5 Data models,” i.e., yang data models in a publicly available git repository with the license statement “No license. All rights reserved.” + +In addition, 3GPP published its 4G Network Resource Model (Information Model); however, this is not yet being referenced and/or used within O-RAN. It should be noted that there is a proposal within O-RAN to model O-eNB that is likely to necessitate the inclusion of elements from 4G NRM as part of a subsequent release. + +To reiterate, the O-RAN Information Model, Data Models, and modeling processes should complement the work of other SDOs, not conflict or compete. + +Accordingly, whenever any O-RAN WG (Working Group) identifies defects and/or omissions in 3GPP models, a Change Request (CR) is fed back into 3GPP for a mutually agreed upon resolution. It should be noted, however, that there is still no formalized process for 3GPP to receive CRs from the O-RAN Alliance. This could be addressed via a statement of intent to be followed by 3GPP member companies that, more often than not, are O-RAN member companies as well. + +Not all identified gaps are within the 3GPP domain. Some may be specific to O-RAN and are not suitable for inclusion in 3GPP. + +As 3GPP CRs are approved, they are incorporated into the O1 Interface Specification. This, in turn, drives the updates that are to be made to both the Information Model and Data Models within O-RAN. Alignment should proceed as a clearly defined sequence of events. + +## 2.2 Information and Data Models as a Modeling Continuum + +Within O-RAN, the de facto methods and procedures with respect to the early stage of an O-RAN “modeling continuum” aim to evolve **one common and coherent Information Model for providing O-RAN extensions to the existing 4G/5G IMs such as the 3GPP NRMs, from which O-RAN Data Models may be generated manually or with a set of tools.** + +![Diagram titled 'Information and Data Models as a Modeling Continuum' showing the relationship between Information Model, Logical Data Model, Data Dictionary, and Component Physical Data Models.](de4ddc87c5c4b44287aec4f93581adf9_img.jpg) + +The diagram illustrates the modeling continuum. At the top, three components are shown in a row: 'Information Model' (represented by a complex network diagram), 'Logical Data Model' (represented by a grid of colored rectangles), and 'Data Dictionary' (represented by a table-like structure). Double-headed blue arrows connect these three components, indicating a continuous relationship. Below this row is a large blue rounded rectangle labeled 'Component Physical Data Models' which contains an illustration of interlocking gears of various colors. A double-headed blue arrow connects the top row of models to the 'Component Physical Data Models' box. To the left of the top row, a blue callout box contains the text 'e.g., Yang, VES, etc.' with an arrow pointing towards the 'Information Model'. To the right of the top row, a text block states the 'Objective: Establish and evolve one common and coherent Information Model for 5G/LTE RAN'. + +Diagram titled 'Information and Data Models as a Modeling Continuum' showing the relationship between Information Model, Logical Data Model, Data Dictionary, and Component Physical Data Models. + +**Figure 1 Information and Data Models as a Modeling Continuum (conceptual)** + +### Definitions: + +**Information Model:** a representation of concepts and the relationships, constraints, rules, and operations to specify data semantics for a chosen domain of discourse. Typically, and Information Model specifies relations between kinds of things, but may also include relations with individual things. It can provide sharable, stable, and organized structure of information requirements or knowledge for the domain context. + +**Data Model:** an abstract model that organizes elements of data and standardizes how they relate to one another and to the properties of real-world entities. The term data model may refer to two distinct but closely related concepts: (1) an abstract formalization of the objects and relationships found in a particular application domain; (2) the set of concepts used in defining such formalizations - for example concepts such as entities, attributes, relations, or tables. + +**Logical Data Model:** a data model of a specific problem domain expressed independently of a particular database management product or storage technology (physical data model) but in terms of data structures such as relational tables and columns, object-oriented classes, or XML tag + +**Data Dictionary:** a centralized repository of information about data such as meaning, relationships to other data, origin, usage, and format + +**Component Physical Data Models:** a representation of a data design as implemented, or intended to be implemented, in a database management system for each component. In the lifecycle of a project it typically derives from a logical data model and will include the database artifacts required to create relationships between tables or to achieve performance goals, such as indexes, constraint definitions, linking tables, partitioned tables or clusters + +## 2.3 Information and Data Modeling Co-Evolution + +The “Modeling Continuum” depicted as Figure 1 (above) is purely conceptual and is intended to provide a framework for Information and Data Modeling Co-evolution that can be applied within both O-RAN and 3GPP, laying the groundwork for collaboration. + +Here is an example of the process to be adapted to, and adopted by, O-RAN: + +![Figure 2: Information and Data Modeling Co-Evolution. A diagram showing the co-evolution of three models: Info Model, Data Model, and API. The process is divided into five stages: 1. High Level Info Requirements, 2. Introduce Info Model, 3. Refine Info Model, 4. Info Model Freeze Final, and 5. Tweaks on Info Model. The Info Model row shows Model Planning, Input model, Discussion Model, Clean Model, and Updates from WG, UCTG. The Data Model row shows Use Case Proposal, U/C Definition, Refine Data Work, Refine Data Model, and Data Model Freeze. The API row shows Use Case Proposal, U/C Definition, U/C Design, U/C Design, and API Approve API Freeze. The diagram includes icons for each stage and arrows indicating the flow between them.](29f9190227c244e2a90c8ca4d717746e_img.jpg) + +| | High Level Info Requirements | Introduce Info Model | Refine Info Model | Info Model Freeze Final | Tweaks on Info Model | +|------------|------------------------------|----------------------|-------------------|-------------------------|------------------------| +| INFO MODEL | Model Planning | Input model | Discussion Model | Clean Model | Updates from WG, UCTG | +| DATA MODEL | Use Case Proposal | U/C Definition | Refine Data Work | Refine Data Model | Data Model Freeze | +| API | Use Case Proposal | U/C Definition | U/C Design | U/C Design | API Approve API Freeze | + +Figure 2: Information and Data Modeling Co-Evolution. A diagram showing the co-evolution of three models: Info Model, Data Model, and API. The process is divided into five stages: 1. High Level Info Requirements, 2. Introduce Info Model, 3. Refine Info Model, 4. Info Model Freeze Final, and 5. Tweaks on Info Model. The Info Model row shows Model Planning, Input model, Discussion Model, Clean Model, and Updates from WG, UCTG. The Data Model row shows Use Case Proposal, U/C Definition, Refine Data Work, Refine Data Model, and Data Model Freeze. The API row shows Use Case Proposal, U/C Definition, U/C Design, U/C Design, and API Approve API Freeze. The diagram includes icons for each stage and arrows indicating the flow between them. + +**Figure 2 Information and Data Modeling Co-Evolution** + +[“Modeling, Use Case and Architecture Process,” B.Cheung et al, May 2019, ONAP] + +## 2.4 Model and Use Case Development (process) + +In addition, there is another evolving process within O-RAN and 3GPP to guide and inform Information Model and Data Model(s) development based on prioritized use cases. + +Once again, alignment between O-RAN and 3GPP is paramount, as the former establishes a de facto “software-driven standard,” while the latter is responsible for the formal approval and acceptance of the full set of release-managed standards for 5G/LTE RAN + +Here is another example of the process to be adapted to, and adopted by, O-RAN. + +![Figure 3: Model and Use Case Development (process). A detailed process diagram showing the flow from Proposals to Integration, categorized into Milestones, Use Case, Modeling, and Architecture.](df6d13ecbe040fdaab04d231ec583591_img.jpg) + +| | Proposals | Planning | Functionality Define | API Develop S/W Coding | Integration | +|---------------------|----------------|-----------------------------------------------|----------------------------------------------|------------------------|------------------| +| MILESTONES | U/C Proposals | Definition | Design, Platform s/W | API, S/W deliverables | Test/Integration | +| USE CASE | U/C Proposal | U/C Definition | U/C Design | U/C Develop | U/C Test | +| MODELING | Model Planning | Input model Discussion Model | Refine, Approve, Employ Model | - | - | +| ARCHITECTURE | - | Functional Arch. Def | Arch Approved | API Doc Freeze | - | +| | | Functional Arch Define Component Architecture | Architecture Approved Component Architecture | API Documents Freeze | | + +Figure 3: Model and Use Case Development (process). A detailed process diagram showing the flow from Proposals to Integration, categorized into Milestones, Use Case, Modeling, and Architecture. + +**Figure 3 Model and Use Case Development (process)** + +[“Modeling, Use Case and Architecture Process,” B.Cheung et al, May 2019, ONAP] + +## 2.5 O-RAN components reflected within O-RAN Information Model and Data Model(s) + +The work to evolve the following O-RAN components will both follow and provide feedback on the OAM Information Model and Data Models of 3GPP: + +- Near-RT-RIC +- O-CU-UP +- O-CU-CP +- O-DU +- O-RU +- O-eNB + +The O-RAN entities listed below are also expected to be reflected within the O-RAN Information Model: + +- Non-RT-RIC: ManagedApplication (rApp), A1-Policies +- Near-RT-RIC; ManagedApplication (xApp), A1 interfaces, A1 Policies, A1-Topology +- E2 interfaces and E2-Topology +- O2 interfaces and O2-Topology [O-Cloud is a future consideration from a modelling perspective] +- O1 + +## 2.6 Open Issues and Future Considerations + +There are numerous Open Issues and Future Considerations that are captured within the O-RAN wiki pages; however, regardless of any future considerations, the guiding principle is clear and remains unchanged, that O-RAN seeks to re-use and/or augment, not re-invent, that which already exists and has been adopted, i.e., withstood the test of time, by the telecommunications industry in the areas of Information and Data Models. + +For the most up-to-date compendium of Open Issues and Future Considerations, please refer to the O-RAN wiki. + +# Chapter 3. O-RAN Information Model + +## 3.1 A general view of an Information Model + +In general, an Information Model is an abstract but formal representation of entities including their properties, relationships and the operations that can be performed on them. It includes a representation of concepts and the relationships, constraints, rules, and operations to specify data semantics for a chosen domain of discourse: + +- Things (Modeled as Classes) with Definitions +- Class Properties (Attributes); Class Relationships +- Association Types (Simple Association, Aggregation, Composition, Inheritance) +- Multiplicity and Direction +- Operations/Behaviors (optional) +- Represented on a Collection of Class Diagrams +- Implementation Independent +- Interfaces – Operations, Attributes (in, out, return) + +## 3.2 Modeling approach, Unified Modeling Language (UML) + +Modeling is the designing of software applications before coding. Modeling is an essential part of large software projects, and helpful to medium and even small projects as well. A model plays the analogous role in software development that blueprints and other plans (site maps, elevations, physical models) play in the building of a skyscraper. + +Models raise the level of abstraction by hiding or masking details, bringing out the “big picture,” or by focusing on different aspects of a prototype. + +The Information Model within O-RAN uses the Unified Modeling Language™ (UML®) from the Object Management Group (OMG) with an open source Model-Based Engineering tool, Eclipse Papyrus. + +## 3.3 IISOMI (Informal Inter-SDO Open Model Initiative) guidelines + +The information model is split into a structural part and a behavioral part; i.e., data model (structural/static) is decoupled from operations model (behavioral/dynamic). + +The following guidelines are sourced from a Technical Recommendation developed within IISOMI (Informal Inter-SDO Open Model Initiative) and originally published by the ONF: + +- UML 2.5 (Unified Modeling Language) is used for specifying the model +- The model shall be management/control protocol-neutral, i.e., not reflect any middleware protocol-specific characteristics (like e.g., CORBA, HTTP, JMS) +- The model shall be map-able to various protocol-specific interfaces (it is recommended to automate this mapping supported by tools) +- It shall be possible to separate UML artifact properties which are only required for interface related (purpose specific) models. +- Traceability from each modeling construct back to requirements and use cases shall be provided whenever possible. + +## 3.4 General Information on the UML Model + +The following general information on the model shall be set/defined, i.e., is captured within the tool (Papyrus) that is currently being used within O-RAN: + +- Namespace - a unique and persistent namespace for the identifiers in the model. +- Organization - a human friendly written name of the SDO/Open Source Project defining the model. +- Contact - detailed information on the project and editor which have developed the model. +- Description - a brief description of the model content; 1 line (optional). +- Copyright - the copyright notice for the model. +- License - the license statement for the model. +- Revision - detailed information on this revision of the model. Each revision of the model should add an additional revision statement. + +## 3.5 O-RAN Information Model + +Typically, the Information Model specifies relations between kinds of things, but may also include relations with individual things. It can provide sharable, stable, and organized structure of information requirements or knowledge for the domain context. + +The complete Information Model in both human- and machine-readable formats as of the date of this document may be found in O-RAN's bitbucket – refer to Appendix A. + +Please make sure that you are logged in using your Atlassian user ID & password. + +**Note that access to the Information Model is purely for informational purposes, as the O-RAN Information Model is still under development and is not yet approved for use.** + +## 3.6 Classes/components and interfaces that comprise the O-RAN Information Model and Data Models + +Following are a list of classes/components as well as interfaces that should be part of the O-RAN Information model, along with the working group developing this entity, any SDO references if appropriate, followed by comments and the status. This is based on the premise that each WG is responsible for modeling the entity within the modeling tool, Eclipse Papyrus, and WG1 is responsible for stewarding the overarching model inclusive of the input from the other groups. + +| Entity | WG Developing Model | Doc Reference | Comments | Status | +|--------------------------|---------------------|----------------|-------------------------------------------------------------------------|--------| +| Class / Component | | | | | +| NonRTRIC | | | Out of scope for O-RAN, but will have interfaces into O-RAN components. | | +| NearRTRIC | WG3 | | Presently shell only in model. | | +| O-CU-CP | WG5 | 3GPP TS 28.541 | 3GPP start, including attributes | | +| O-CU-UP | WG5 | 3GPP TS 28.541 | 3GPP start, including attributes | | +| O-DU | | 3GPP TS 28.541 | 3GPP start, including attributes | | + +| | | | | | +|-------------------|-----|-----------------------------|----------------------------------------------------------|--| +| O-RU | | | Shell only | | +| ManagedElement | | 3GPP TS 28.622 | Class and attributes | | +| Xapp | | | Not present in model | | +| | | | | | +| Interfaces | | | | | +| A1-P | WG2 | O-RAN.WG2.A1AP-v03.00 | | | +| A1-ML | WG2 | | Shell Only - to be pursued in a later release | | +| A1-EI | WG2 | | Shell Only - to be pursued in a later release | | +| O1 | WG1 | O-RAN-WG1.O1 Interface -v04 | | | +| E1 | WG5 | 3GPP TS 38.460 | 3GPP start, including operations list | | +| E2 | WG3 | ORAN-WG3.E2GAP.0-v0.1 | Interface with 9 operations | | +| F1-c | WG5 | 3GPP TS 38.470 | 3GPP start, including 24 operations | | +| F1-u | WG5 | 3GPP TS 38.470 | 3GPP start, including limited operation list | | +| OpenFrontHaul | WG4 | front-haul mplane / cus | Shell only | | +| X2 | WG5 | 3GPP TS 36.423 | 3GPP based start, including a large number of operations | | +| O2 | WG6 | | Not present in model | | + +**Table 1 Classes/components and interfaces that comprise the O-RAN Information Model and Data Model(s)** + +## 3.7 Installing and using Papyrus + +Eclipse Papyrus is an industrial-grade open source Model-Based Engineering tool. Eclipse Papyrus has notably been used successfully in industrial projects and is the base platform for several industrial modeling tools. + +**Information about this tool and how to use it as well as how it is being used within O-RAN may be found in Appendix B.** + +# Chapter 4. O-RAN Data Models + +For O1 interfaces, the O-RAN Information Model development should precede and serve as the basis for the Data Model development within each working group (WG1 through WG9). + +## 4.1 Repositories; current conventions to distinguish between models under development versus models that are approved for use + +The data models are developed and published in working group specific bitbucket that are expected to be available at the time this document is published: + + + + + + + + + + + + + + + + + + + +**Note that these are private repositories that include models that are under development, i.e., not yet approved for use.** + +O-RAN users who require access to bitbucket are instructed to email the WG co-chair(s) with “O-RAN WG\_ REPO ACCESS” in the Subject: field, filling in the blank “WG\_” with the number of the WG for which repository access is being requested. + +**The link to the public-facing repository that includes the formally released versions of models may be found within Appendix C.** + +There is a convention to identify formally published data models and distinguish them from models that are considered “experimental,” i.e., still under development, not yet approved for use: + +*The revision statement in all YANG models includes a reference statement used to cross-reference the first version of the document where the corresponding description was introduced. For example, the reference in all revision statements for the initial O-RAN models from WG4 include cross-reference to “ORAN-WG4.MP.0-v01.00”.* + +*The revision statement of the YANG models also includes a description that is used to track the versioning of the YANG model. All revision statement descriptions will begin with “version ”“.”“.”, where , and are used to reflect the version of the YANG model, where* + +* corresponds to the first digit of the O-RAN specification version where the corresponding description was first introduced, corresponding to in sub-section 1.1;* + +* is incremented when errors in the YANG model have been corrected;* + +* is incremented only in working versions of the YANG model indicating incremental changes during the editing process.* + +## 4.2 Formal relationship (traceability) between O-RAN Data Models and the O-RAN Information Model + +At present, there is no formal relationship and/or traceability between the O-RAN Data Models and O-RAN Information Model; however, this is expected to evolve over time. + +As indicated within Chapter 2 “Overview and Philosophy,” there is a modeling continuum that aims to establish and evolve one common and coherent Information Model for 5G/LTE RAN from which Data Models may be generated either manually or with a set of tools. + +As the modeling practices and processes within O-RAN mature, the Information Model and Data Models are expected to co-evolve to develop the APIs required by specific use cases, as depicted below. + +![Information and Data Modeling Co-Evolution diagram showing the progression of Info Model, Data Model, and API across five stages: Model Planning, U/C Definition, Refine Info Model, Refine Data Model, and API Approve.](8c654b4c612ee701d8f2d9f11bdbc27a_img.jpg) + +The diagram illustrates the co-evolution of three modeling layers: INFO MODEL, DATA MODEL, and API, across five sequential stages. The stages are represented by vertical columns, and the layers are represented by horizontal rows. Arrows indicate the flow of development and dependencies between stages and layers. + +| | Model Planning | U/C Definition | Refine Info Model | Refine Data Model | API Approve | +|-------------------|------------------------------------------------|-------------------------------------|---------------------------------------|--------------------------------------------|-----------------------------------------------| +| INFO MODEL | High Level Info Requirements
Model Planning | Introduce Info Model
Input model | Refine Info Model
Discussion Model | Info Model Freeze Final
Clean Model | Tweaks on Info Model
Updates from WG, UCTG | +| DATA MODEL | Use Case Proposal | U/C Definition | Refine Data Work
Input Data Model | Refine Data Model
Discussion Data Model | Data Model Freeze
Clean Data Model | +| API | Use Case Proposal | U/C Definition | U/C Design | U/C Design | API Approve
API Freeze
Preliminary API | + +Vertical arrows on the left indicate dependencies: API depends on DATA MODEL, which depends on INFO MODEL. Horizontal arrows at the top of each layer indicate the progression from left to right across the stages. + +Information and Data Modeling Co-Evolution diagram showing the progression of Info Model, Data Model, and API across five stages: Model Planning, U/C Definition, Refine Info Model, Refine Data Model, and API Approve. + +**Figure 4 Information and Data Modeling Co-Evolution** + +[“Modeling, Use Case and Architecture Process,” B.Cheung et al, May 2019, ONAP] + +## 4.3 Usage of 3GPP Data Models + +The O-RAN Alliance complements the work of other SDOs. 3GPP is the primary source for management plane specifications for O-RAN components. 3GPP has published its “Trial - SA5 Data models” including its yang data models in a public available git repository with the license statement “No license. All rights reserved.” + +Please refer to Appendix C for the 3GPP-source Data Models that are approved for use. + +The following table (snapshot) shows a subset of the mapping of 3GPP yang data models to O-RAN element functions as defined by OAM Architecture Specifications. For the most current mapping, please refer to the O-RAN wiki. + +| 3GPP yang data model | 3GPP spec for YANG model | o-ru
(in hybrid mode) | o-du | o-cu-up | o-cu-cp | near-rt-ric | +|-------------------------------|--------------------------|----------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------| +| _3gpp-5g-common-yang-types | 3GPP TS 28.541 | imported by _3gpp-common-managed-element | imported by _3gpp-common-managed-element | imported by _3gpp-common-managed-element | imported by _3gpp-common-managed-element | imported by _3gpp-common-managed-element | +| _3gpp-common-ep-rp | 3GPP TS 28.623 | [open] o-ran-m-int.yang & o-ran-ru-if.yang defines the interface of O-RU, maybe it is not needed to O-RU | imported by _3gpp-nr-nrm-ep

abstract superclass for all 3GPP endpoints

[open] as O-RU remote PORT, to configure eCPRI port of O-DU just EP_RP looks not enough | imported by _3gpp-nr-nrm-ep

abstract superclass for all 3GPP endpoints | imported by _3gpp-nr-nrm-ep

abstract superclass for all 3GPP endpoints | [open] need discussion , if RIC modeled as O-RU which need detailed configuration to interfaces, the common part probably from IETF | +| _3gpp-common-fm | 3GPP TS 28.623 | imported by _3gpp-common-managed-element

needed for alarm list handling | imported by _3gpp-common-managed-element

needed for alarm list handling | imported by _3gpp-common-managed-element

needed for alarm list handling | imported by _3gpp-common-managed-element

needed for alarm list handling | imported by _3gpp-common-managed-element

needed for alarm list handling | +| _3gpp-common-managed-element | 3GPP TS 28.623 | root object class | root object class | root object class | root object class | root object class | +| _3gpp-common-managed-function | 3GPP TS 28.623 | needed to extend MF for O-RU functionality | imported by _3gpp-nr-nrm-gnbdufunction | imported by _3gpp-nr-nrm-gnbcuupfunction | imported by _3gpp-nr-nrm-gnbcuCPfunction | needed either for a standalone RIC or combined RIC ME | +| _3gpp-common-measurements | 3GPP TS 28.623 | imported by _3gpp-common-managed-element

needed for PM job control and threshold monitoring | imported by _3gpp-common-managed-element

needed for PM job control and threshold monitoring | imported by _3gpp-common-managed-element

needed for PM job control and threshold monitoring | imported by _3gpp-common-managed-element

needed for PM job control and threshold monitoring | imported by _3gpp-common-managed-element

needed for PM job control and threshold monitoring | + +| | | | | | | | +|-----------------------------------|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| _3gpp-common-subnetwork | 3GPP TS 28.623 | imported by _3gpp-common-subscription-control
not needed from O-RAN point of view but cant be removed with modification of the yang, Contribution to 3GPP required | imported by _3gpp-common-subscription-control
not needed from O-RAN point of view but cant be removed with modification of the yang, Contribution to 3GPP required | imported by _3gpp-common-subscription-control
not needed from O-RAN point of view but cant be removed with modification of the yang, Contribution to 3GPP required | imported by _3gpp-common-subscription-control
not needed from O-RAN point of view but cant be removed with modification of the yang, Contribution to 3GPP required | imported by _3gpp-common-subscription-control
not needed from O-RAN point of view but cant be removed with modification of the yang, Contribution to 3GPP required | +| _3gpp-common-subscription-control | 3GPP TS 28.623 | needed for VES subscription | needed for VES subscription | needed for VES subscription | needed for VES subscription | needed for VES subscription | +| _3gpp-common-top | 3GPP TS 28.623 | imported by _3gpp-common-managed-element

abstract class supplying a naming attribute | imported by _3gpp-common-managed-element

abstract class supplying a naming attribute | imported by _3gpp-common-managed-element

abstract class supplying a naming attribute | imported by _3gpp-common-managed-element

abstract class supplying a naming attribute | imported by _3gpp-common-managed-element

abstract class supplying a naming attribute | +| _3gpp-common-yang-extensions | 3GPP TS 28.623 | expected for inVariant | expected for inVariant | expected for inVariant | expected for inVariant | expected for inVariant | +| _3gpp-common-yang-types | 3GPP TS 28.623 | imported by many other 3GPP yang modules

essential 3GPP typedefs, in particular DistinguishedName, and other useful typedefs like OperationalState, AdministrativeState, AvailabilityStatus | imported by many other 3GPP yang modules

essential 3GPP typedefs, in particular DistinguishedName, and other useful typedefs like OperationalState, AdministrativeState, AvailabilityStatus | imported by many other 3GPP yang modules

essential 3GPP typedefs, in particular DistinguishedName, and other useful typedefs like OperationalState, AdministrativeState, AvailabilityStatus | imported by many other 3GPP yang modules

essential 3GPP typedefs, in particular DistinguishedName, and other useful typedefs like OperationalState, AdministrativeState, AvailabilityStatus | imported by many other 3GPP yang modules

essential 3GPP typedefs, in particular DistinguishedName, and other useful typedefs like OperationalState, AdministrativeState, AvailabilityStatus | + +**Table 2 Mapping of 3GPP yang data models to O-RAN element functions** + +## 4.4 Usage of non-3GPP data models + +There are domains of data-models being considered by O-RAN WGs (Working Groups) that are not covered by 3GPP but are covered by other SDOs, e.g., IETF, MEF, IEEE, ONF, BBF, and occasionally imported by 3GPP. + +Note that this is merely a snapshot as of the date of this document and is expected to be revisited as part of subsequent release(s). + +The following table shows data models that are of interest and being considered within O-RAN and/or 3GPP: + +| Order No | yang data model | o-ru (to be revised to separate O1 and M-Plane) | o-du | o-cu-up | o-cu-cp | near-rt-ric | Comments | +|----------|----------------------------|-----------------------------------------------------------------|----------------------------------------|----------------------------------------|----------------------------------------|----------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| 001 | ietf-yang-types | import by several models including _3gpp-common-yang-types.yang | import by _3gpp-common-yang-types.yang | import by _3gpp-common-yang-types.yang | import by _3gpp-common-yang-types.yang | import by _3gpp-common-yang-types.yang | | +| 002 | ietf-inet-types | import by several models including _3gpp-common-yang-types.yang | import by _3gpp-common-yang-types.yang | import by _3gpp-common-yang-types.yang | import by _3gpp-common-yang-types.yang | import by _3gpp-common-yang-types.yang | | +| 011 | ietf-netconf.yang | must have | must have | must have | must have | must have | | +| 012 | ietf-netconf-acm.yang | baseline for access control | | | | | Network Configuration Access Control Model | +| 013 | ietf-netconf-monitoring | used by WG4 M-Plane | | | | | NETCONF Monitoring Module | +| 014 | ietf-netconf-nmda | | | | | | NETCONF operations to support the Network Management Datastore Architecture | +| 015 | ietf-netconf-notifications | not O1 but OpenFronthaul mPlane | not O1 but OpenFronthaul mPlane | | | | This module defines a YANG data model for use with the NETCONF protocol that allows the NETCONF client to receive common NETCONF base event notifications | +| 016 | ietf-netconf-partial-lock | | | | | | | +| 017 | ietf-netconf-time | | | | | | time-triggered configuration and management operations | +| 018 | ietf-netconf-with-defaults | | | | | | NETCONF client to control how default values are handled by the server in particular NETCONF operations | + +| | | | | | | | | +|-----|---------------------|----------------------------------------------------------------------|---------------------------------|--|--|--|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 020 | ietf-system | overlaps with o-ran-operations but may be required to support 802.1X | | | | | configuration and identification of some common system properties within a device containing a NETCONF server
  • time-zone management
  • radius
  • local users
  • NTP
| +| 030 | ietf-hardware | not O1 but OpenFronthaul mPlane | not O1 but OpenFronthaul mPlane | | | | | +| 031 | iana-hardware | import by ietf-hardware | import by ietf-hardware | | | | IANA-defined identities for hardware class. | +| 032 | ietf-hardware-state | | | | | | hardware monitoring | +| 033 | ietf-interfaces | foundation for fronthaul | | | | | | +| 034 | iana-if-type | not O1 but OpenFronthaul mPlane | not O1 but OpenFronthaul mPlane | | | | YANG identities for IANA-registered interface types | +| 040 | ietf-alarms | | | | | | This module defines an interface for managing alarms. | +| | ietf-ip | foundation for fronthaul M-Plane | | | | | managing IP implementations | +| | ietf-ntp | considered - but decided o define own o-ran-sync.yang | | | | | configuration of IEEE Std 1588-2008 clocks | +| | ietf-yang-library | foundation for YANG 1.1 | | | | | | +| | ietf-yang-metadata | | | | | | This YANG module defines an 'extension' statement that allows for defining metadata annotations | +| | ietf-yang-patch | | | | | | This module contains conceptual YANG specifications for the YANG Patch and YANG Patch Status data structures. | + +| | | | | | | | | +|--|------------------------|-----------------------------------|--|--|--|--|---------------------------------------------------------------------------------------------------------------------------------------| +| | ietf-yang-push | | | | | | | +| | ietf-yang-schema-mount | | | | | | This module defines a YANG extension statement that can be used to incorporate data models defined in other YANG modules in a module. | +| | ietf-yang-smiv2 | | | | | | This module defines YANG extensions that are used to translate SMIv2 concepts into YANG. | +| | iana-crypto-hash | used in CTI | | | | | | +| | ietf-crypto-types | used by fronthaul file management | | | | | | +| | ieee802-dot1x | being considered by STG | | | | | | + +**Table 3 Non 3GPP yang models** + +## 4.5 YANG Conventions + +This section describes the recommended conventions to be used in the O-RAN Alliance when writing YANG models. + +In particular, because the creation and maintenance of YANG models is expected to be distributed across different working groups, this guide is intended to ensure that the way the models are organized and presented will be consistent across the entirety of the O-RAN Alliance. + +### 4.5.1 Naming + +**MODULE FILE NAMING:** M-Plane YANG modules should have filenames of the form “o-ran-xxx.yang” (for O1 the file naming is TBD) + +**MODULE NAMESPACE:** YANG modules should have a namespace defined of the form namespace "urn:o-ran:xxx:version"; where version represents an increasing numerical integer value and where the value used in all newly defined models is "1". The module namespace version will be incremented when any non-backwards compatible changes are introduced into a model. + +**PREFIX NAMING:** Each module requires a prefix statement with a prefix that other dependent modules will use (also used in path references within the same module). Prefixes should be short and clear, with abbreviations as appropriate. Module prefixes should be of the form: o-ran-xxx, or or-xxx, and must be unique regardless of over which interface the YANG module is exposed (ex. O1 or Open FrontHaul M-Plane). + +### 4.5.2 Revision Statement + +The revision statement in all YANG models includes a reference statement used to cross-reference to the version of a particular O-RAN publication where the corresponding functionality was initially introduced. The revision statement of the YANG models also includes a description that is used to track the versioning of the YANG model. All revision + +statement descriptions will begin with version a.b.c, where a, b and c are used to reflect the version of the YANG model, where 'a' corresponds to the first digit of the O-RAN specification version where the corresponding description was first introduced; 'b' is incremented when errors in the YANG model have been corrected; 'c' is incremented only in working versions of the YANG model indicating incremental changes during the editing process. Hence, all published versions of O-RAN alliance YANG models should have this value set to zero. + +### 4.5.3 Indents + +O-RAN Alliance YANG models should use two-space tab indents. + +### 4.5.4 YANG Language Usage + +**YANG VERSION:** All models should use YANG data modeling language version 1.1 [1] (RFC 7950) and follow the Guidelines for Authors and Reviewers of YANG Data Model Documents [RFC 6087]. + +**TOP-LEVEL DATA NODE:** There should only be one top-level data node defined in each YANG module, if any data nodes are defined at all. + +**NMDA (Network Management Datastore Architecture):** No O-RAN YANG models should prevent the use of NMDA [RFC 8342]. + +**KEY-LESS LISTS OF OPERATIONAL STATE:** Although permitted in YANG, the use of a list that consists of operational-state without a defined key should be avoided. + +**VALIDATION:** All YANG modules should be validated / compiled with pyang tool using the following flag: `pyang --lint `. Note, successful compilation with pyang does not guarantee a working model, as xPATH expressions aren't evaluated and forbidden operational data dependencies in the configuration may not generate appropriate errors. + +**NETCONF ACCESS CONTROL:** Sensitive data within models should be tagged with an appropriate "nacm:default" statement. O-RAN makes use of NACM (NETCONF Access Control Model RFC 8341) rules to define the privileges associated with user groupings. An O-RAN NETCONF server should hard code these restrictions into the server. The defined NACM rules are therefore unmodifiable, with the rules being used to provide an "external indication" of such restrictions. + +**CONSTRAINTS:** Generally, O-RAN systems should strive to consider a blank configuration to be a valid config. + +### 4.5.5 Cross Working Group Co-ordination + +Models that are likely to be applicable to more than one O-RAN Alliance working group should provide clear delineation between separate working groups configuration and/or state. The use of feature and if-feature is recommended to ensure that NETCONF servers are not required to implement the entire data model, e.g., when aspects of such relate to the individual working group defined use cases. The feature name should indicate which working group the capabilities have been defined by. + +# --- Annex A: Link to Information Model source (under development; not approved for use) + +Papyrus sources for the O-RAN Information Model can be found in O-RAN's bitbucket: . + +Please make sure that you are logged in using your Atlassian userID and password. + +# Annex B: Installing and using Eclipse Papyrus [refer to O-RAN wiki for the most up-to-date guidelines] + +Eclipse Papyrus is an industrial-grade open source Model-Based Engineering tool. Eclipse Papyrus has notably been used successfully in industrial projects and is the base platform for several industrial modeling tools. + +Eclipse Papyrus provides editors for all the UML diagrams: + +- Class Diagram +- Object Diagram +- Package Diagram +- Composite Structure Diagram +- Component Diagram +- Deployment Diagram +- Profile Diagram +- Use case Diagram +- Activity Diagram +- State machine Diagram +- Communication Diagram +- Sequence Diagram +- Timing Diagram +- Interaction overview Diagram + +## Installation + +The Open Source UML tool Papyrus is a plug-in for the Open Source integrated development environment (IDE) Eclipse. GenDoc is the associated tool that allows you to output a model in Papyrus into a word document. The artifacts in the output (diagrams, classes, datatypes, etc.) can be copy/pasted directly into a model project's wiki page. + +Currently applied tool versions: + +- Eclipse: version 4.8 "Photon" +- Papyrus: version 4.0.0 +- GenDoc: version 0.6.0 + +Note: the full list of IISOMI-recommended modelling tool downloads in all versions is here: + + + +- **Eclipse** +- Eclipse "Photon" Modeling Tools package version 4.8 can be downloaded from here: + +- Select the download link that is appropriate for the machine on which you will be making the install, i.e. "Windows 64-bit" +- This results in the download of a zip file. + +- Note that Eclipse Photon requires a 1.8 compatible JVM +- Extract the contents of the zip file to wherever you would like to install Eclipse. On a PC, "Program Files" is always a good option. +- The content of the extracted files should look something like this: + +![Screenshot of the Eclipse Photon installation directory contents. The directory contains folders for configuration, dropins, features, p2, plugins, and readme. It also contains files: .eclipseproduct, about.html, artifacts.xml, eclipse.exe, eclipse.ini, eclipsesec.exe, epl-v10.html, and notice.html.](bb690bed8abad3938e821fbb0a45ed7d_img.jpg) + +Screenshot of the Eclipse Photon installation directory contents. The directory contains folders for configuration, dropins, features, p2, plugins, and readme. It also contains files: .eclipseproduct, about.html, artifacts.xml, eclipse.exe, eclipse.ini, eclipsesec.exe, epl-v10.html, and notice.html. + +- To launch eclipse, double-click on the "eclipse.exe" file +- When Eclipse starts coming up, it will prompt you for a "Workspace", providing a default that you can override. +- This is where the Eclipse projects, with associated models, will be stored. +- When Eclipse fully comes up, you can close the Welcome tab +- To verify you have the correct installation of the product, go to "Help" → "About Eclipse" +- You should see something that looks like + +![Screenshot of the 'About Eclipse IDE' dialog box. It shows 'Eclipse Modeling Tools' with version 'Photon Release (4.8.0)' and build id '20180619-1200'.](f187d3c8a01b9fb3cf20567e63d8d3ff_img.jpg) + +Screenshot of the 'About Eclipse IDE' dialog box. It shows 'Eclipse Modeling Tools' with version 'Photon Release (4.8.0)' and build id '20180619-1200'. + +- You have now successfully installed Eclipse +- **Papyrus** +- Papyrus Photon version 4.0.0 can be downloaded from here: + +- Scroll down on the right side of the page and select: "Papyrus Photon 4.0.0 " and select "Download Page" +- This takes you to "Papyrus Update Site for Photon" +- Copy the URL of the update site to which it takes you. Should be something like: for latest version) +- Now you go back into Eclipse and select "Help"→ "Install new software" + +![Screenshot of the 'Available Software' dialog box in Eclipse. The dialog shows a list of software items with checkboxes. The 'Papyrus' item is selected. The 'Work with:' field contains a URL. The 'Next' button is highlighted.](390879f49a2b9895bc017094b7c9bbd5_img.jpg) + +Screenshot of the 'Available Software' dialog box in Eclipse. The dialog shows a list of software items with checkboxes. The 'Papyrus' item is selected. The 'Work with:' field contains a URL. The 'Next' button is highlighted. + +- An "Available Software" screen comes up. Paste your URL into the "Work with:" box and hit enter +- There should be multiple "Papyrus" related packages available to install. Select only the box: "Papyrus" and make sure the others are not selected. +- Click "Next" to install the product. The installation will check for dependencies and requirements +- You will get a screen indicating what will be installed + - Papyrus for UML + - Papyrus for UML Developer Resources +- Select Next +- The install will then prompt you to "Accept" the license agreement +- Once accepted, you can select "Finish" and the installation process continues. Note: The installation might take a while, and perhaps even appear to hang for a while. You can see in the lower right hand corner of + +Eclipse the progress on the install. + +![Screenshot of the Eclipse progress bar showing 'Installing Software: (48%)' with a green progress indicator.](388928824cf728fa6396032b2bb1726d_img.jpg) + +Screenshot of the Eclipse progress bar showing 'Installing Software: (48%)' with a green progress indicator. + +- When the installation is finished, restart Eclipse to begin to use Papyrus. +- Go to "Window" → "Perspective" → "Open Perspective" → "Other" and select Papyrus. +- You will now be in the Papyrus Perspective where you can begin to use Papyrus. +- **GenDoc** + +The Gendoc plugin is used in conjunction with a document template. The template contains instructions that enable generation of a Microsoft Word document. The document can include extracts from the model such as diagrams, class definitions, attribute definitions along with their stereotypes etc as well as figures and text directly entered into the template. + +- 1       • In Eclipse, go to "Help" → "Install new software" +- 2       • Enter the GenDoc site: in the "Work with" + +![Screenshot of the Eclipse 'Available Software' dialog box. The 'Work with' field contains the URL 'http://download.eclipse.org/gendoc/updates/releases/0.6.0/'. Below this is a table with columns 'Name' and 'Version'. The 'Name' column contains 'GenDoc'. Below the table are several checkboxes: 'Show only the latest versions of available software', 'Group items by category', 'Show only software applicable to target environment', and 'Contact all update sites during install to find required software'. There are also buttons for 'Select All', 'Deselect All', 'What is already installed?', 'Next', 'Cancel', and 'Help'.](2ee688bfbd2e5e0ad32087385d3f5dc3_img.jpg) + +Screenshot of the Eclipse 'Available Software' dialog box. The 'Work with' field contains the URL 'http://download.eclipse.org/gendoc/updates/releases/0.6.0/'. Below this is a table with columns 'Name' and 'Version'. The 'Name' column contains 'GenDoc'. Below the table are several checkboxes: 'Show only the latest versions of available software', 'Group items by category', 'Show only software applicable to target environment', and 'Contact all update sites during install to find required software'. There are also buttons for 'Select All', 'Deselect All', 'What is already installed?', 'Next', 'Cancel', and 'Help'. + +- 3       section and hit enter. +- 4       • The "gendoc" package should show. Select this package and hit "Next". +- 5       • Follow the instructions to complete the installation. Note: You may get a warning message about installing software that contains unsigned content - select "Install anyway". +- 6 +- 7       • A Restart will be required to apply the changes. +- 8 + +# Annex C: Links to Data Models approved for use + +### From O-RAN + +The public facing web page that includes the formally released versions of models that are approved for use: + +[www.o-ran.org/specifications](http://www.o-ran.org/specifications) + +### From 3GPP + +3GPP is one of the sources for management plane specifications for O-RAN components. 3GPP publishes its “SA5 Data models” including its yang data models in a public available git repository: + + + +### From IETF + +IETF is a complementary source for management plane specifications for O-RAN components. IETF publishes its yang data models (inclusive of IANA yang data models) in a public available git repository: + + + +# Annex ZZZ : O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN + +Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal + +grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of O-RAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER + +PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED “AS IS” WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance’s sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity’s or association’s agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates’ performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties’ or third party beneficiary’s right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full force and effect. \ No newline at end of file diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/0b0d6eb63283940961bc5b6e9e76e073_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/0b0d6eb63283940961bc5b6e9e76e073_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..97b6c91a6e06ed6f98785b8236552768d362f44f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/0b0d6eb63283940961bc5b6e9e76e073_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:277e94e9bc717429f9818f12ad3456896fb0e02e5c7a09c6241524b2e0a86f9f +size 108986 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/109a381f93f2dee7722856f6e802ff1b_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/109a381f93f2dee7722856f6e802ff1b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2a25abce9881a3e1044e40181b1c75603b00bc6e --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/109a381f93f2dee7722856f6e802ff1b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8662d7d30d706af4349e3a63917fedc03ec14acb9776f9c7e4c88de4b94e6c1c +size 54765 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/17158c6bfd9aa2dfd2551d218ac337e7_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/17158c6bfd9aa2dfd2551d218ac337e7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3fa3887d386e51cc3a7d8791a065cbbb5c8e9040 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/17158c6bfd9aa2dfd2551d218ac337e7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:71a60917381c7aa683ff6ca8d9a0761cb0fdc76ad70e96a741b0be83e511a390 +size 121739 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/17398cfc35dde22fa5a80caabe669739_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/17398cfc35dde22fa5a80caabe669739_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ae115f85c71c7c4dd5ac246f8d02e9dc29c8af6 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/17398cfc35dde22fa5a80caabe669739_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c5775240b9ed1a2100a9c61aca08d03763ec191986acc2c52895232c0e85e48b +size 4429 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/29981ff643dee2929c47fe2c72c6dd15_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/29981ff643dee2929c47fe2c72c6dd15_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e30563723f521a79b73b41eec9b0479f669a811c --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/29981ff643dee2929c47fe2c72c6dd15_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:340ecfd781543ae5b07e5402c81d95f487706209058afd8c01d56262c2747a24 +size 58943 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/4092c8460753403c32d0fe1bf17500e0_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/4092c8460753403c32d0fe1bf17500e0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..26d6a45808ab8a9e102805d6b5501c2ce802377d --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/4092c8460753403c32d0fe1bf17500e0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8303a3a7d6cad4bda71c299290e901fb08f1917870dc519f089a9613b2f2be54 +size 201092 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/45ca5b5d3befcf2021e8ad1e9a1fdc42_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/45ca5b5d3befcf2021e8ad1e9a1fdc42_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e3d6ed4715238f386f134b44831cb586b3106b42 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/45ca5b5d3befcf2021e8ad1e9a1fdc42_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3c9d9b4259c7949bc1b9cf5160ae283008a512a738cb1cb66d21ac4321f6bb8e +size 104344 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/48e766a24d37cb68c327dfc465f58b73_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/48e766a24d37cb68c327dfc465f58b73_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..792e0ac54717a89b5a24a1b37377cd9c985b40ab --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/48e766a24d37cb68c327dfc465f58b73_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:59fe342c427711c5f90cf4ef2d586a71e8e56d19a265a8f92e96973b6ca56334 +size 34747 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/497c638391dae365ad12f1ebd687c445_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/497c638391dae365ad12f1ebd687c445_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..008ff69f0900d366186f2f68e6ee8cbfc18c468e --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/497c638391dae365ad12f1ebd687c445_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09238b459f3ad3429d2ba3917bc267325e8584c48d205b49916cca0dba7fbd7c +size 4549 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/4ff1eba818ce089f4258346993d7fb8e_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/4ff1eba818ce089f4258346993d7fb8e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d7e4e404d0d3d78595a6cb951b8377bef171522a --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/4ff1eba818ce089f4258346993d7fb8e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab82fac5b59f1fc84440dbb9a8e3bd7e0bcdf47c7c74dd4cf80d377df59b0b35 +size 82906 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/51d4eb8480021a8101426aa25f36c176_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/51d4eb8480021a8101426aa25f36c176_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..49574754d806e115129931770ed6183349904406 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/51d4eb8480021a8101426aa25f36c176_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:539209a37add20836cdb8e0885a9c1d1366b79864b58ac90793065beaeefc47a +size 115651 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/551e35d264492786d0d610557ccc1b55_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/551e35d264492786d0d610557ccc1b55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eca96f14eff173ab5ead5b4ef80ff5827e92c33d --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/551e35d264492786d0d610557ccc1b55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8bb0af2dd788e055159db7a05c0b9285e7d655c861421ac8dc37e4b94c3b343 +size 4454 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/5818dc6b386a994b6de98b5085d16ce5_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/5818dc6b386a994b6de98b5085d16ce5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5473a8f22c5c5305125a7c03802e4ee4ae9d2238 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/5818dc6b386a994b6de98b5085d16ce5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ebe903fdc0ba28b7d3abf4f3e707020f25c886d366936c6f6004aae6f0ce1e04 +size 41563 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/628bbd7300dbe4e1226c3937a9674d19_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/628bbd7300dbe4e1226c3937a9674d19_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..56ff3e56c718bfceed8e33758bdcc1e8df951858 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/628bbd7300dbe4e1226c3937a9674d19_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:40d3f517416efb29c83859cbfa4f9fd6a915cd677a342b2ccae5b724277c46ae +size 125780 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/65ed1005c1fee99c885dc4ea2f175c20_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/65ed1005c1fee99c885dc4ea2f175c20_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4bd921f9187b9ea39313a01ef63b62b733375759 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/65ed1005c1fee99c885dc4ea2f175c20_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2f252984f468aa5ca8a5810aec82361fdc4ae18fb2c5f3082916d9bf02d0457f +size 57034 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/676c91b64382565d972aaef1aeb60f35_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/676c91b64382565d972aaef1aeb60f35_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..17e9aeebaaf53d6100482d20b8dbdbd363ecb52b --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/676c91b64382565d972aaef1aeb60f35_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b0f20f21b66dfe1b951c86e5ef199d9677e37716f224c6a93c40e9a0a2979aa5 +size 4549 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/6b7163fd031312df1ebf24ebf8a8ab47_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/6b7163fd031312df1ebf24ebf8a8ab47_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0df44b5a8543e0c98743c3573421f95990353792 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/6b7163fd031312df1ebf24ebf8a8ab47_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b9c2463c512af2a0ab2a0e2d868750fcc72ad742a06e34d9ebb80a75b2365f1b +size 56478 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/6c442018ecaaeda3eabb60f36849253c_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/6c442018ecaaeda3eabb60f36849253c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1af6d3ee765775396abcf9bed6d2feed5d612528 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/6c442018ecaaeda3eabb60f36849253c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9070f35ba6c5ee1b14e58c776cebea584ce00817810f3852951da44596b7e583 +size 60124 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/821a20f64ac189eef89f204d3697c3e3_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/821a20f64ac189eef89f204d3697c3e3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7725e65432a6565dc0c7c9acfb9899b46b4667ed --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/821a20f64ac189eef89f204d3697c3e3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da3f8a5663f70ee0b473dc01133fac22c83210674426bfcf8048025747aa315b +size 38632 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/855e6df9dae27be31f76f8e0c069cd12_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/855e6df9dae27be31f76f8e0c069cd12_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d09fa9d491d1d859bd24e9b7503373e23736bb11 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/855e6df9dae27be31f76f8e0c069cd12_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7559a76dc5ace46be1c02d85b5ed2482959cfb4a368c82c51b0af23f8c4f7cc3 +size 159948 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/9eef0972d4326f7548c7f66eaaa66f3a_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/9eef0972d4326f7548c7f66eaaa66f3a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b9e1c54cc15030e28d37b9b8a814903db16d0309 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/9eef0972d4326f7548c7f66eaaa66f3a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bb3d83a2d5c04fb76ce5f8696c573f615a9ac8e7257ca6131e166d3ffca0995a +size 191544 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/bb19a24fab1cb3a2b51f82fef2ea3b61_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/bb19a24fab1cb3a2b51f82fef2ea3b61_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1e4339cbe312363fdb23b8f050547dd70447af48 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/bb19a24fab1cb3a2b51f82fef2ea3b61_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d976b7dcf50b3ae7bff9c51ec8e99373a2c9422e88bfa5330e2e6919a312e40d +size 4528 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/c0bba4421681d4d0e7f7f58549f97556_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/c0bba4421681d4d0e7f7f58549f97556_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..869d1af4d77bcfbc7f4f403625db6946b15ebfaa --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/c0bba4421681d4d0e7f7f58549f97556_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a3e675687057ccf8cd79de50c5f3be2170409e133d43a730e497b7acd7eda7fc +size 165877 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2b90693e69025867d0dd05d8f98d4ef9b4bf8d2 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ed2f1f4ac06a8bc6ac44f6e3f61e762e6c8489952cf16d65bfea30fe61adb2af +size 4677 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d5642ca291e5e00ad8bb543aa273595d_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d5642ca291e5e00ad8bb543aa273595d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..50c141fdd91121709fbc4511035b0982cf73be26 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d5642ca291e5e00ad8bb543aa273595d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:140a801230b8475e6ff2f9fa8f711c7ae278c9d6ed3400a7b7a74feaa504e4bf +size 4518 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2607b0eef27677fb38e9fdbba214fde5d86a7f72 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9e383e92647a2356488a833110e26ad296a5dd136dd01f365e78a67474a8258 +size 4548 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d9b5a2ee4b5cb3b0aa74c5b02322fcb3_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d9b5a2ee4b5cb3b0aa74c5b02322fcb3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..faffbb1cc81d8cb3ae50a7db090e88b080eb53f1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/d9b5a2ee4b5cb3b0aa74c5b02322fcb3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bc5f6406e9d1e0df964d7ddce69977350405cc14bfdd9649daa01c0e566948ee +size 68079 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/f11b1040576ac8bdbc2b2ec4ace6eceb_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/f11b1040576ac8bdbc2b2ec4ace6eceb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d02c76a6d63b318d27934e749d34c77f18e101a4 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/f11b1040576ac8bdbc2b2ec4ace6eceb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8665d34d29a4b84a431365b883a45b6bb02e90d6d2c3e748112f4516d0a1e404 +size 226830 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/fe7ee60a1d75fc06043aa008f4f81f3a_img.jpg b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/fe7ee60a1d75fc06043aa008f4f81f3a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..54f92019f244caaeaaf2ebe0f180211a31cfc6fb --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/fe7ee60a1d75fc06043aa008f4f81f3a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8cbc80bc8268df40242b3e0006278cc4e978a17b6a9290ca4b1340dba9320418 +size 145790 diff --git a/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/raw.md b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..b207402ff70bc7ffd6adc982d646f032542bfffe --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00/raw.md @@ -0,0 +1,3130 @@ + + +# --- **O-RAN Work Group 1 (Use Cases and Overall Architecture)****Network Energy Saving Use Cases Technical Report** + +Copyright © 2023 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +# Contents + +| | | +|-------------------------------------------------------------------------|----| +| Foreword..... | 5 | +| Modal verbs terminology ..... | 5 | +| 1 Scope..... | 6 | +| 2 References..... | 6 | +| 2.1 Informative references ..... | 6 | +| 3 Definition of terms, symbols and abbreviations..... | 7 | +| 3.1 Terms ..... | 7 | +| 3.2 Symbols ..... | 7 | +| 3.3 Abbreviations..... | 7 | +| 4 Objectives and Requirements..... | 8 | +| 4.1 Objectives ..... | 8 | +| 4.2 Requirements ..... | 9 | +| 5 Carrier and Cell Switch Off/On ..... | 10 | +| 5.1 Problem Statement, Solution and Value Proposition..... | 10 | +| 5.2 Architecture/Deployment Options ..... | 11 | +| 5.2.1 Option 1: Non-RT RIC Deployment..... | 11 | +| 5.2.1.1 Description and UML Diagram ..... | 11 | +| 5.2.1.2 O-RAN Entity Roles..... | 14 | +| 5.2.1.3 Input/Output Data Requirements ..... | 14 | +| 5.2.1.3.1 Summary..... | 14 | +| 5.2.1.3.2 Detailed Input Requirements ..... | 15 | +| 5.2.1.3.3 Detailed Output Requirements..... | 18 | +| 5.2.2 Option 2: Near-RT RIC Deployment..... | 19 | +| 5.2.2.1 Description and UML Diagram ..... | 19 | +| 5.2.2.2 O-RAN Entity Roles..... | 22 | +| 5.2.2.3 Input/Output Data Requirements..... | 22 | +| 5.2.2.3.1 Summary..... | 22 | +| 5.2.2.3.2 Detailed Input Requirements ..... | 24 | +| 5.2.2.3.3 Detailed Output Requirements..... | 27 | +| 5.3 Impact Analysis on O-RAN Work Groups..... | 27 | +| 5.4 Relation and Impact on 3GPP Specifications ..... | 29 | +| 5.4.1 Relation to 3GPP RAN Specifications ..... | 29 | +| 5.4.2 Ongoing Work in 3GPP Rel.18 RAN..... | 29 | +| 5.4.3 Impact on 3GPP RAN Specifications ..... | 30 | +| 5.4.4 Relation to 3GPP System Architecture Specifications..... | 30 | +| 5.4.5 Ongoing Work in 3GPP Rel.18 System Architecture ..... | 31 | +| 5.4.6 Impact on 3GPP System Architecture Specifications ..... | 31 | +| 5.5 Gain Analysis..... | 31 | +| 5.5.1 Cell and Carrier Switch Off/On Energy Saving for 4T4R O-RU..... | 33 | +| 5.5.2 Cell and Carrier Switch Off/On Energy Saving for 64T64R O-RU..... | 34 | +| 5.6 Feasibility Analysis..... | 35 | +| 6 RF Channel Reconfiguration..... | 36 | +| 6.1 Problem Statement, Solution and Value Proposition..... | 36 | +| 6.2 Architecture/Deployment Options ..... | 37 | +| 6.2.1 Option 1: Non-RT RIC Deployment..... | 37 | +| 6.2.1.1 Description and UML Diagram ..... | 38 | +| 6.2.1.2 O-RAN Entity Roles..... | 41 | +| 6.2.1.3 Input/Output Data Requirements ..... | 41 | +| 6.2.1.3.1 Summary..... | 41 | +| 6.2.1.3.2 Detailed Input Requirements ..... | 43 | +| 6.2.1.3.3 Detailed Output Requirements..... | 47 | +| 6.2.2 Option 2: Near-RT RIC Deployment..... | 47 | + +| | | | +|-----------|---------------------------------------------------------------------|----| +| 6.2.2.1 | Description and UML Diagram ..... | 48 | +| 6.2.2.2 | O-RAN Entity Roles..... | 51 | +| 6.2.2.3 | Input/Output Data Requirements ..... | 52 | +| 6.2.2.3.1 | Summary ..... | 52 | +| 6.2.2.3.2 | Detailed Input Requirements ..... | 53 | +| 6.2.2.3.3 | Detailed Output Requirements..... | 56 | +| 6.3 | Impact Analysis on O-RAN Work Groups ..... | 56 | +| 6.4 | Relation and Impact on 3GPP Specifications ..... | 58 | +| 6.5 | Gain Analysis..... | 58 | +| 6.5.1 | RF Channel Reconfiguration ES Gain Analysis for 4T4R O-RU ..... | 58 | +| 6.5.2 | RF Channel Reconfiguration ES Gain Analysis for 64T64R O-RU ..... | 60 | +| 6.6 | Feasibility Analysis..... | 61 | +| 6.6.1 | Continuous operation during RF Channel Reconfiguration ..... | 61 | +| 6.6.2 | Impact on Coverage ..... | 61 | +| 6.6.3 | Impact and Relation to UE specific Base Station Algorithms..... | 61 | +| 6.6.4 | Limited O-RU / O-DU Capabilities ..... | 61 | +| 7 | Advanced Sleep Mode Selection..... | 62 | +| 7.1 | Problem Statement, Solution and Value Proposition ..... | 62 | +| 7.2 | Architecture/Deployment Options ..... | 64 | +| 7.2.1 | Option 1: Training and Inference in Non-RT RIC ..... | 64 | +| 7.2.1.1 | Description and UML Diagram ..... | 65 | +| 7.2.1.2 | O-RAN Entity Roles..... | 69 | +| 7.2.1.3 | Void ..... | 69 | +| 7.2.2 | Option 2: Training in Non-RT RIC and Inference in Near-RT RIC ..... | 69 | +| 7.2.2.1 | Description and UML Diagram ..... | 70 | +| 7.2.2.2 | O-RAN Entity Roles..... | 74 | +| 7.2.2.3 | Void ..... | 74 | +| 7.3 | Impact Analysis on O-RAN Work Groups ..... | 75 | +| 7.4 | Relation and Impact on 3GPP Specifications ..... | 76 | +| 7.5 | Void ..... | 76 | +| 7.6 | Feasibility Analysis..... | 76 | +| 7.6.1 | Impact to Continuous Operation during Advance Sleep Modes ..... | 76 | +| 7.6.2 | Impact to Coverage ..... | 76 | +| 7.6.3 | Impact and Relation to Vendor Specific Scheduling Algorithms..... | 77 | +| 7.6.4 | Limited O-RU/O-DU Capabilities ..... | 77 | +| 8 | O-Cloud Resource Energy Saving Mode ..... | 78 | +| 8.1 | Sub Use Case 1: O-Cloud Node Shutdown ..... | 78 | +| 8.1.1 | Problem Statement, Solution and Value Proposition ..... | 78 | +| 8.1.2 | Architecture/Deployment Option ..... | 79 | +| 8.1.2.1 | Description and UML Diagram ..... | 81 | +| 8.1.2.2 | O-RAN Entity Roles..... | 85 | +| 8.1.2.3 | Void ..... | 85 | +| 8.1.3 | Impact Analysis on O-RAN Work Groups ..... | 86 | +| 8.1.4 | Relation and Impact on 3GPP Specifications..... | 86 | +| 8.1.5 | Void..... | 86 | +| 8.1.6 | Feasibility Analysis..... | 86 | +| 8.1.6.1 | Service Continuity during NF relocation..... | 86 | +| 8.1.6.2 | Pooling vs. Scaling Gains..... | 86 | +| 8.1.6.3 | Start-up Time for Scale Out Operation..... | 86 | +| 8.2 | Sub Use Case 2: O-Cloud CPU Energy Saving Mode..... | 87 | +| 8.2.1 | Problem Statement, Solution and Value Proposition ..... | 87 | +| 8.2.2 | Architecture/Deployment Option ..... | 88 | +| 8.2.2.1 | Description and UML Diagram ..... | 89 | +| 8.2.2.2 | O-RAN Entity Roles..... | 92 | +| 8.2.2.3 | Void ..... | 92 | +| 8.2.3 | Impact Analysis on O-RAN Work Groups ..... | 92 | +| 8.2.4 | Relation and Impact on 3GPP Specifications..... | 92 | +| 8.2.5 | Void..... | 93 | +| 8.2.6 | Feasibility Analysis..... | 93 | +| 8.2.6.1 | Not to Restrict Fast CPU Energy Saving Mode Switching ..... | 93 | + +| | | | +|---|----------------------------------------------------------------------|-----| +| 9 | Summary and Conclusion ..... | 94 | +| | Annex A (Informative): Design Principles for NES Features ..... | 96 | +| | Annex B (Informative): Load profile and O-RU functional blocks ..... | 98 | +| | Annex C (Informative): O1 interface principles..... | 100 | +| | Annex D (Informative): Examples of Advanced Sleep Modes ..... | 104 | +| | Revision history ..... | 105 | +| | History ..... | 105 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +--- + +# Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should O-RAN modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Version x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +The present document provides a technical report on Network Energy Saving use cases. + +--- + +# 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [1] 3GPP TR 21.905, Vocabulary for 3GPP Specifications +- [2] ETSI ES 203 228, Environmental Engineering (EE); Assessment of mobile network energy efficiency +- [3] O-RAN Technical Specification, O-RAN Architecture Description +- [4] O-RAN Technical Specification, Non-RT RIC Architecture +- [5] O-RAN Technical Report, Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN +- [6] O-RAN Technical Specification, Use Cases Detailed Specification +- [7] 3GPP TS 28.554, Management and orchestration; 5G end to end Key Performance Indicators (KPI) +- [8] 3GPP TS 28.310, Management and orchestration; Energy efficiency of 5G +- [9] 3GPP TS 38.300, NR; NR and NG-RAN Overall Description, Stage-2 +- [10] ETSI ES 202 706-1, Metrics and measurement method for energy efficiency of wireless access network equipment; Part 1: Power consumption - static measurement method + +- [11] 3GPP TS 28.541, Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3 +- [12] 3GPP TS 28.552, Management and orchestration; 5G performance measurements +- [13] 3GPP TS 32.425, Telecommunication management; Performance Management (PM); Performance measurements Evolved Universal Terrestrial Radio Access Network (E-UTRAN) +- [14] 3GPP TS 32.451, Telecommunication management; Key Performance Indicators (KPI) for Evolved Universal Terrestrial Radio Access Network (E-UTRAN); Requirements +- [15] 3GPP TS 32.551, Telecommunication management; Energy Saving Management (ESM); Concepts and requirements +- [16] 3GPP TS 38.331, NR; Radio Resource Control (RRC); Protocol specification +- [17] O-RAN Technical Specification, O-RAN Outdoor Macrocell Hardware Architecture and Requirements (FR1) +- [18] O-RAN Technical Specification, O-RAN Operations and Maintenance Interface Specification +- [19] 3GPP TR 38.864, Study on network energy savings for NR +- [20] O-RAN Technical Specification, O2 Interface General Aspects and Principles + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [1]. + +**Energy Efficiency:** relation between the useful output and energy/power consumption as defined in ETSI ES 203 228 [2] + +**Energy Consumption:** integral of power consumption over time as defined in ETSI ES 202 706-1 [10] + +## 3.2 Symbols + +No symbol is defined in this TR. + +## 3.3 Abbreviations + +For the purposes of this document, the abbreviations given in 3GPP TR 21.905 [1], 3GPP TS 38.300 [9], ETSI ES 203 228 [2], O-RAN.WG1.O-RAN-Architecture-Description [3], O-RAN.WG6.CADS [5] apply. + +# 4 Objectives and Requirements + +## 4.1 Objectives + +This Technical Report captures the outcome of the WG1 UCTG Network Energy Saving pre-normative phase. The objectives of the pre-normative phase are as follows: + +- study and investigate all required counters/KPI's for monitoring and reporting of Energy Consumption and Energy Efficiency in real time for all O-RAN defined nodes such as O-RU, O-DU, O-CU as well as 3GPP defined logical components of network such as Cell, Carrier, gNB, +- study requirements, key issues, proposed solutions, benefits of the Energy Saving proposals, +- study potential impact and required enhancements to O-RAN interfaces such as E2, O1, A1, FH M-plane, FH CUS-Plane, R1, and Near-RT RIC API, +- study potential impact and required enhancements on data models of all O-RAN entities, +- identify the any possible impact on Non-RT RIC architecture, Near-RT RIC architecture and AI/ML workflow. + +The use cases studied in the NES pre-normative phase are: + +- Carrier and Cell Switch Off/On +- RF Channel Reconfiguration Off/On +- Advanced Sleep Mode Selection +- O-Cloud Resource Energy Saving Mode + +Algorithms discussed and analyzed as part of the Network ES pre-normative phase will be examples only and will not be part of any specification as outcome of this pre-normative phase or subsequent work items. + +For each use case solution proposal, the detailed objectives are: + +- Review, evaluate applicability of, and select from existing deployment alternatives (Non-RT and/or Near-RT RIC) and AI/ML deployment scenarios and document respective findings: + - Evaluate energy savings gains based on a E2 Node/O-RU/PNF/VNF energy consumption model using evaluation metrics/KPIs and including assessment of impact on network and user performance. + - Study on a per sub-use case basis potential impact and enhancements on O-RAN interfaces (e.g. O1, O2, A1, E2, O-FH) in terms of required input data and output configuration data. + - Review existing counters, KPIs, and data models as specified/studied in 3GPP. + - Study potential enhancements on existing counters, KPIs, and data models or define new counters, KPIs, and data models of all involved O-RAN entities. + +NES use cases should reuse the existing 3GPP measurements and measurement reporting for input data as well as the existing 3GPP configuration and provisioning management for the output data as much as possible. + +If new measurements or configuration parameters are essential to support new NES use cases, then these should preferably be based on parameters, variables, definitions and procedures that are already used in the 3GPP/O-RAN specifications. The current standardization approach (specifying the new measurement in 3GPP specifications and referring to it in O-RAN specifications) should be prioritized over inventing new standardization approaches. + +## 4.2 Requirements + +This TR shall capture Energy consumption and Energy Efficiency related counters and KPIs including the following: + +### **O-RU Specific KPIs** + +- Energy Efficiency and power consumption KPIs provided by real-time metering. + +### **O-CU/O-DU Hardware & Software / O-Cloud Software & Platform KPIs** + +- O-CU/O-DU hardware (e.g., CPU, accelerators, NIC cards, fans and power supply, etc.) shall have the capability to measure and report power consumption values to the O-Cloud. The O-Cloud software shall be able to collect measurement data at the hardware component level (e.g., CPU, NIC, accelerator card, fans and power supply, etc.) and provide power, energy and environmental (PEE) parameters/KPIs. O-Cloud shall be able to report EE through O2 interface to the SMO or through North-Bound Interfaces (NBI) to external tools. +- The O-Cloud software shall be able to provide PEE parameters/KPIs at the workload level (e.g., pod, O-CU/O-DU CNF, etc.), as well as for the O-Cloud platform software components themselves. O-Cloud shall be able to report energy efficiency through O2 interface to the SMO or through NBI to external tools. +- O-CU and O-DU shall provide CNF level energy efficiency counters/KPIs (e.g., power consumption, Traffic load, data volume, throughput), which shall be reported through O1 interface to the SMO or through NBI to external tools. + +# 5 Carrier and Cell Switch Off/On + +## 5.1 Problem Statement, Solution and Value Proposition + +Mobile networks often utilize multiple frequency layers (carriers) to cover the same service area. At low load, i.e. when the expected traffic volume is lower than a fixed threshold, ES can be achieved by switching off one or more carriers or entire cells without impairing the user experience. UEs previously served by the carrier or cell will be offloaded by the E2 Node to a new target carrier or cell prior to the switch off. + +However, the switch off/on decisions are not a trivial task. There are conflicting targets between system performance and energy savings. Other carriers and/or cells will have to serve the additional traffic and traffic is changing over time. E2 Nodes support a number of techniques effecting energy consumption which might also be load dependent. While energy savings for the switched off carrier and/or cell is maximized, the overall energy consumption of the network might even increase. + +Carrier and cell switch off/on control by the Non-RT or Near-RT RIC can consider overall network energy efficiency instead of local optimization. The switch off/on decision can optionally be made by an AI/ML model within the inference host, deployed at the Non-RT RIC (deployment option 1) or at the Near-RT RIC (deployment option 2) to further improve decision making. Among others, the AI/ML models' functionality may include prediction of future traffic, user mobility, and resource usage and may also predict expected energy efficiency enhancements, resource usage, and network performance for different ES optimization states. + +Before switching off/on carrier(s) and/or cell(s), the E2 Node may need to perform some preparation actions for off switching (e.g. check ongoing emergency calls and warning messages, to enable, disable, modify Carrier Aggregation and/or Dual Connectivity, to trigger HO traffic and UEs from cells/carriers to other cells or carriers, informing neighbour nodes via X2/Xn interface etc.) as well as for on switching (e.g., cell probing, informing neighbour nodes via X2/Xn interface etc.). + +## 5.2 Architecture/Deployment Options + +### 5.2.1 Option 1: Non-RT RIC Deployment + +In option 1, decision making, potentially including AI/ML Model Training and Inference, is done at the Non-RT RIC. + +#### 5.2.1.1 Description and UML Diagram + +**Table 5.2.1.1-1: Carrier and Cell Switch Off/On: AI/ML inference via Non-RT RIC** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Enable Carrier and Cell switch off/on Energy Saving functions in the Network by means of configuration parameter change and Actions controlled by Non-RT RIC and allow for AI/ML-based solutions. | | +| Actors and Roles | Non-RT RIC acting as inference host for Energy Savings decision making.
E2 Node and O-RU are the subject of action for configuration enforcement. | | +| Assumptions | O1 interface connectivity is established.
Open FH M-Plane interface is established between E2 Node and O-RU and/or SMO and O-RU directly.
Network is operational.
Non-RT RIC has knowledge about overlapping carriers/cells and the coverage of those carriers/cells (e.g., which carrier/cell is a coverage layer and which is a capacity layer). | | +| Pre-conditions | The operator has set the targets for Energy Saving functions in the Non-RT RIC. | | +| Begins when | Operator enables the optimization functions for carrier and cell switch off/on Energy Saving functions and E2 Node and O-RU become operational. | | +| Step 1 (M) | SMO initiates specific measurement data collection request towards E2 Node and O-RU (via E2 Node and O-FH) for AI/ML model training and inference. | | +| Step 2 (M) | E2 Node and O-RU send the configured measurement data to SMO periodically or event based. | | +| Step 3 (M) | Non-RT RIC retrieves the collected measurement data for processing. | | +| Step 4 (M) | Non-RT RIC trains the AI/ML models with the collected data. Trained AI/ML models are deployed, configured, and activated.

Non-RT RIC constantly monitors
(i) performance and energy consumption of the E2 Node(s)
(ii) energy consumption of O-RU(s) | | +| Step 5 (M) | Based on the AI/ML inference the Non-RT RIC may request the SMO to configure E2 Node to prepare and execute cell or carrier switch off/on. | | +| Step 6 (M) | SMO instructs E2 Node via O1 interface to perform the received request(s) from the Non-RT RIC. O-RU is informed about the updated O-RU configuration via Open FH M-Plane interface by E2 Node. E2 Node will notify SMO once cell or carrier switch off/on is completed. | | +| Step 7 (M) | Non-RT RIC continuously analyzes performance of AI/ML model. If energy saving objectives are not achieved, it may decide to initiate fallback mechanism, and/or AI/ML model update or retraining. | | +| Ends when | E2 Node becomes non-operational or when the operator disables the optimization functions for Energy Saving. | | +| Exceptions | None. | | +| Post Conditions | Non-RT RIC continues closed-loop monitoring of Energy Saving function at E2 Node and O-RU.
E2 Node(s) and O-RU(s) operate using the newly deployed parameters/models and state (off/on). | | + +``` + +@startuml +Skin rose +skinparam defaultFontSize 12 +autonumber + +Box "Service Management & \n Orchestration Framework" #gold + +Participant "Collection & Control" as SMO +Participant "Non-RT RIC" as NRTRIC + +End box + +Box "O-RAN Nodes" #lightpink + Participant "Near-RT RIC" as RTRIC + Participant "E2-Nodes" as E2NODES + Participant "O-RUs" as ORUs +End box + +group Data Collection +autonumber 1.1 +SMO -> E2NODES : <> Data collection request for Energy Saving +E2NODES -> ORUs : <> Data collection request for Energy Saving + +autonumber 2.1 +ORUs -> E2NODES : <> Measurement Data Collection for Energy Saving +E2NODES -> SMO : <> Measurement Data Collection for Energy Saving +autonumber 3 +SMO -> NRTRIC : Data retrieval +end + +group Data Analysis Training and Inference +autonumber 4.1 + + NRTRIC -> NRTRIC : Performance and Energy Consumption Monitoring \n(E2 Node(s) & O- +RU(s)) + NRTRIC -> NRTRIC : AI/ML Model training and inference +end + +autonumber 5 +group Actor Decision Making + NRTRIC -> SMO : Request to prepare and execute \nfor carrier(s) and cell(s) switch +off/on +end + +autonumber 6.1 + +SMO <-> E2NODES : <> E2-Node parameter configurations and recommendation for +carrier(s) and cell(s) switch off/on, \nmessage response and/or notification of +execution. + E2NODES <-> ORUs : <> Update O-RU Configurations \nand notification of +update + +autonumber 7 + + NRTRIC -> NRTRIC : Performance analysis of AI/ML model \n(with possible actions, e.g. +fallback, re-training) +end + +@enduml + +``` + +![Sequence diagram for Carrier and Cell Switch Off/On flow diagram: AI/ML inference via Non-RT RIC. The diagram shows interactions between Service Management & Orchestration Framework (Collection & Control, Non-RT RIC) and O-RAN Nodes (Near-RT RIC, E2-Nodes, O-RUs). The process is divided into three main phases: Data Collection, Data Analysis Training and Inference, and Actor Decision Making.](0b0d6eb63283940961bc5b6e9e76e073_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management & Orchestration Framework + participant NRT as Non-RT RIC + participant NearRT as Near-RT RIC + participant E2 as E2-Nodes + participant ORU as O-RUs + + Note over SMO: Data Collection + SMO->>NearRT: 1.1 <> Data collection request for Energy Saving + NearRT->>E2: 1.2 <> Data collection request for Energy Saving + E2->>ORU: 2.1 <> Measurement Data Collection for Energy Saving + ORU-->>E2: + E2-->>NearRT: 2.2 <> Measurement Data Collection for Energy Saving + NearRT-->>SMO: 3 Data retrieval + + Note over SMO: Data Analysis Training and Inference + SMO->>NRT: 4.1 Performance and Energy Consumption Monitoring (E2 Node(s) & O-RU(s)) + NRT-->>SMO: + SMO->>NRT: 4.2 AI/ML Model training and inference + NRT-->>SMO: + + Note over SMO: Actor Decision Making + SMO->>NRT: 5 Request to prepare and execute for carrier(s) and cell(s) switch off/on + NRT-->>SMO: + SMO->>NearRT: 6.1 <> E2-Node parameter configurations and recommendation for carrier(s) and cell(s) switch off/on, message response and/or notification of execution. + NearRT->>E2: + E2->>ORU: 6.2 <> Update O-RU Configurations and notification of update + ORU-->>E2: + E2-->>NearRT: + NearRT-->>SMO: + SMO->>NRT: 7 Performance analysis of AI/ML model (with possible actions, e.g. fallback, re-training) + NRT-->>SMO: + +``` + +Sequence diagram for Carrier and Cell Switch Off/On flow diagram: AI/ML inference via Non-RT RIC. The diagram shows interactions between Service Management & Orchestration Framework (Collection & Control, Non-RT RIC) and O-RAN Nodes (Near-RT RIC, E2-Nodes, O-RUs). The process is divided into three main phases: Data Collection, Data Analysis Training and Inference, and Actor Decision Making. + +Figure 5.2.1.1-1: Carrier and Cell Switch Off/On flow diagram: AI/ML inference via Non-RT RIC + +#### 5.2.1.2 O-RAN Entity Roles + +##### 1) Non-RT RIC + +- a) Collect configurations, performance indicators and measurement reports (e.g., cell load related information and traffic information, EE/EC measurement reports, geolocation information) from SMO, E2 Nodes and O-RUs (forwarded by SMO), for the purpose of decision making, optionally using training and inference of AI/ML models that assist such EE/ES functions. +- b) (Optionally) Trigger EE/ES AI/ML model training/retraining. +- c) (Optionally) Deploy, update, configure EE/ES AI/ML models in Non-RT RIC. +- d) Analyze the received data from SMO, E2 Nodes, and O-RUs to determine EE/ES optimization (i.e. if carriers or cells are recommended to be switched off/on), optionally using AI/ML models +- e) Signal updated configurations for EE/ES optimization to E2 Nodes (O-CU) via R1/O1. + +##### 2) E2 Node + +- a) Report cell configuration, performance indicators and measurement reports (e.g., cell load related information and traffic information, EE/EC measurement reports) to SMO via O1 interface. +- b) Perform actions required for EE/ES optimization + - o e.g. check ongoing emergency calls and warning messages, perform some preparation actions for Off Switching (e.g., to enable, disable, modify Carrier Aggregation and/or Dual Connectivity, to trigger HO traffic and UEs from cells/carriers to other cells or carriers, informing neighbour nodes via X2/Xn interface etc.) as well as for On Switching (e.g., cell probing, informing neighbour nodes via X2/Xn interface etc.) and make final decision on switch off/on and notify SMO via O1 about performed actions + +##### 3) O-RU + +- a) Report EC and EE related information via Open FH M-Plane interface to O-DU or alternatively to SMO directly. +- b) Support actions required to perform EE/ES optimization. + - o updated carrier configuration (i.e. activation, deactivation or sleep) + +#### 5.2.1.3 Input/Output Data Requirements + +##### 5.2.1.3.1 Summary + +###### Input Data + +###### 1) E2 Node to SMO/Non-RT RIC + +- Carrier/cell characteristics +- EE/EC measurement reports +- Load statistics per cell and per carrier +- UE mobility information including cell or beam level measurements (e.g. RSRP, RSRQ, SINR) +- Energy consumption + +###### 2) O-RU to E2 Node + +- Power consumption metrics: Mean total/per carrier power consumption, mean total/per carrier transmit power + +###### Output Data + +###### 1) SMO to E2 Node + +- Carrier(s) and/or cell(s) recommended to be switched off/on + +##### 5.2.1.3.2 Detailed Input Requirements + +Initialization: + +**Table 5.2.1.3-1: Initialization** + +| Input Data | | | | | | +|------------|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------|-------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing /New Definitions | +| R1 | SMO / rApp | Optimization target for Carrier/Cell Switch Off/On | | manual or event triggered | New | +| | | E.g., (average or max) NG-RAN data Energy Efficiency | bit/J | | 3GPP TS 28.554 [7] (Cl. 6.7.1) | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | Carrier/cell characteristics | - | manual or event triggered (e.g., SMO feature activation, E2 Node startup / failure / reconfig.) | New | +| | | E.g., physical location, transmit direction, carrier frequency, coverage parameters, configured transmit power, beam width, coverage shape, tilt, azimuth, carrier-cell mapping, carrier-HW mapping | | | 3GPP TS 28.541 [11] (Cl. 4.3.6, 4.3.38, 4.3.39, 4.3.40, 4.3.74)

O-RAN.WG5.O-DU-O1 (Sec. 10), O-RAN-WG5.O-CU-O1 (Sec. 9) | + +###### AI/ML Model Training: + +**Table 5.2.1.3-2: AI/ML Model Training** + +| Input Data | | | | | | +|---------------------------------------------------|-----------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------|-------|------------------------------|-----------------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing Definitions | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | DL PDCP SDU Data Volume per interface (Data Volume in DL delivered from O-CU-UP to O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.3) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | UL PDCP SDU Data Volume per interface (Data Volume in UL delivered to O-CU-UP from O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.4) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | RSRQ measurement per SSB per cell | dB | (non-real time for training) | Measurement:
3GPP TS 28.552 [12] (Cl. 5.1.1.31) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | RSRP measurement per SSB per cell | dBm | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.22) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | SINR measurement per SSB per cell | dB | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.32) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Energy consumption | kWh | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.19.3) | +| O-FH (M-Plane)
or
O-FH (M-Plane),
O1, R1 | O-RU / O-DU
or
O-RU / O-DU / SMO / rApp | Power consumed by hardware component | W | (non-real time for training) | Measurement:
3GPP TS 28.552 [12] (Cl. 5.1.1.19.2)

Reporting:
O-RAN.WG4.MP
(Sec. B.1, B.5) | +| O-FH (M-Plane)
or
O-FH (M-Plane),
O1, R1 | O-RU / O-DU
or
O-RU / O-DU / SMO / rApp | Transmit power | mW | (non-real time for training) | Measurement and reporting:
O-RAN.WG4.MP
(Sec. B.1, B.2.1) | + +Input Decision Making / AI/ML Inference: + +**Table 5.2.1.3-3: Input Decision Making / AI/ML Inference** + +| Input Data | | | | | | +|---------------------------------------------------|-----------------------------------------------|------------------------------------------------------------------------------------------------------------------------|-------|------------------|--------------------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing Definitions | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Data Volume in DL delivered from O-CU-UP to O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U) | Mbit | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.3) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Data Volume in UL delivered to O-CU-UP from O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U) | Mbit | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.4) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | RSRQ measurement per SSB per cell | dB | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.31) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | RSRP measurement per SSB per cell | dBm | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.22) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | SINR measurement per SSB per cell | dB | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.32) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Energy consumption | kWh | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.19.3) | +| O-FH (M-Plane)
or
O-FH (M-Plane),
O1, R1 | O-RU / O-DU
or
O-RU / O-DU / SMO / rApp | Power consumed by hardware component | W | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.19.2)

Reporting:
O-RAN.WG4.MP
(Sec. B.1, B.5) | +| O-FH (M-Plane)
or
O-FH (M-Plane),
O1, R1 | O-RU / O-DU
or
O-RU / O-DU / SMO / rApp | Transmit power | mW | > min | Measurement and reporting:
O-RAN.WG4.MP
(Sec. B.1, B.2.1) | + +##### 5.2.1.3.3 Detailed Output Requirements + +Output Decision Making / AI/ML Inference: + +**Table 5.2.1.3-4: Output Decision Making / AI/ML Inference** + +| Output Data | | | | | | +|----------------|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------|-------|-----------------|----------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Config. Period | Existing Definitions | +| O1, R1 | rApp / SMO / E2 Node (O-CU) | Candidate carrier(s) / cells (s) recommended for energy saving to enter energySaving state (e.g., 3GPP TS 28.310 [8] Sec. 6.2.2) | - | > min | 3GPP TS 28.541 [11] (Cl. 4.3.63)
O-RAN-WG5.O-CU-O1 (Sec. 9) | +| | | Candidate carrier(s) / cell (s) for compensation (e.g., 3GPP TS 32.551 [15] compensatingForEnergySaving, optional) | - | > min | - | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Confirmation (Success/Failure) | - | event triggered | 3GPP TS 28.310 [8] (Cl. 6.2.2) | +| O-FH (M-Plane) | E2 Node (O-DU) / O-RU | Updated carrier configuration (i.e., activation, deactivation, or sleep) | - | > min | O-RAN.WG4.MP (Sec. 15.3.2) | + +### 5.2.2 Option 2: Near-RT RIC Deployment + +In option 2, decision making, potentially using AI/ML Model Inference, is done at Near-RT RIC. While AI/ML Model Training might be hosted in Non-RT or Near-RT RIC, the description below is based on AI/ML Model Training in the Non-RT RIC. + +#### 5.2.2.1 Description and UML Diagram + +**Table 5.2.2.1-1: Carrier and Cell Switch Off/On: AI/ML inference via Near-RT RIC** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Enable Carrier and Cell switch off/on Energy Saving functions in the Network by means of configuration parameter change and Actions controlled by Near-RT RIC and allow for AI/ML-based solutions. | | +| Actors and Roles | Non-RT RIC acting as AI/ML model management entity.
Near-RT RIC acting as inference host for Energy Savings decision making.
E2 Node and O-RU are the subject of action for configuration enforcement. | | +| Assumptions | O1 connectivity is established between the SMO with E2 Node, and Near-RT RIC and Non-RT RIC.
E2 interface connectivity is established between E2 Node and Near-RT RIC.
A1 interface is established between Non-RT RIC and Near-RT RIC.
Open FH M-Plane interface is established between E2 Node and O-RU.
Network is operational.
Near-RT RIC has knowledge about overlapping carriers/cells and the coverage of those carriers/cells (e.g., which carrier/cell is a coverage layer and which is a capacity layer). | | +| Pre-conditions | The operator has set the targets for Energy Saving function in the Non-RT RIC. | | +| Begins when | The operator enables the optimization functions for carrier and cell switch off/on Energy Saving functions and E2 Node and O-RU become operational. | | +| Step 1 (M) | SMO initiates specific measurement data collection request towards E2 Node and O-RU for AI/ML model training. | | +| Step 2 (M) | E2 Node and O-RU send the configured measurement data to SMO periodically or event based. | | +| Step 3 (M) | Non-RT RIC retrieves the collected measurement data for processing | | +| Step 4 (M) | Non-RT RIC trains the AI/ML models with the collected data. Trained AI/ML models are deployed, configured, and activated in the Near-RT RIC. | | +| Step 5 (M) | SMO may trigger EE/ES optimization and might provide policies guiding the Near-RT RIC EE/ES function via O1 and/or via Non-RT RIC and A1 interface. | | +| Step 6 (M) | Near-RT RIC constantly monitors
(i) performance and energy consumption of the E2 Node(s)
(ii) energy consumption of O-RU(s)
Based on the AI/ML inference, considering optimization policies, the Near-RT RIC may request the E2 Node to prepare and execute cell or carrier switch off/on. E2 Node may request O-RU Node to prepare and execute cell or carrier switch off/on. E2 Node will notify Near-RT RIC once cell or carrier switch off/on is completed. | | +| Ends when | E2 Node becomes non-Operational or when the operator disables the optimization functions for Energy Saving. | | +| Exceptions | None. | | +| Post Conditions | Near-RT RIC continues closed-loop monitoring of Energy Saving function at E2 Node and O-RU.
E2 Node and O-RU operate using the newly deployed parameters/models and state (off/on). | | + +``` + +@startuml +skin rose +skinparam defaultFontSize 12 +autonumber + +Box "Service Management & \n Orchestration Framework" #gold + +Participant "Collection & Control" as SMO +Participant "Non-RT RIC" as NRTRIC + +End box + +Box "O-RAN Nodes" #lightpink + Participant "Near-RT RIC" as RTRIC + Participant "E2-Nodes" as E2NODES + Participant "O-RUs" as ORUs +End box + +group Data Collection +autonumber 1.1 +SMO -> E2NODES : <> Data collection request for Energy Saving +E2NODES -> ORUs : <> Data collection request for Energy Saving + +autonumber 2.1 +ORUs -> E2NODES : <> Measurement Data Collection for Energy Saving +E2NODES -> SMO : <> Measurement Data Collection for Energy Saving +autonumber 3 +SMO -> NRTRIC : Data retrieval + +end + +autonumber 4.1 +group AI/ML workflow + + NRTRIC -> NRTRIC : AI/ML Model training + NRTRIC -> RTRIC : <> or <> Deploy AI/ML model + +end + +autonumber 5.1 +group Optimization Trigger and Policy + alt + SMO -> RTRIC : <> Optimization Trigger/Target + else + NRTRIC -> RTRIC : <> AI Policy + end +end + +autonumber 6.1 +group Actor Data Collection & Decision Making + RTRIC -> E2NODES : <> Data collection request for Energy Saving + E2NODES -> ORUs : <> Data collection request for Energy Saving + ORUs -> E2NODES : <> Measurement Data Collection for Energy Saving + E2NODES -> RTRIC : <> Measurement Data Collection for Energy Saving + + RTRIC -> RTRIC : AI/ML model inference + RTRIC <-> E2NODES : <> E2-Node parameters configuration and actions \nfor +carrier(s) and cell(s) switch off/on preparation & execution \n and notication of +execution + E2NODES <-> ORUs : <> Update O-RU configurations \nand notification of update + +end +@enduml + +``` + +![Sequence diagram for AI/ML inference via Near-RT RIC. The diagram shows interactions between the Service Management & Orchestration Framework (Collection & Control, Non-RT RIC) and O-RAN Nodes (Near-RT RIC, E2-Nodes, O-RUs). The process includes Data Collection, AI/ML workflow (training and deployment), Optimization Trigger and Policy, and Actor Data Collection & Decision Making.](51d4eb8480021a8101426aa25f36c176_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management & Orchestration Framework + participant NRT as Near-RT RIC + participant E2 as E2-Nodes + participant ORUs as O-RUs + + SMO->>NRT: 1.1 <> Data collection request for Energy Saving + NRT->>E2: 1.2 <> Data collection request for Energy Saving + E2->>ORUs: 2.1 <> Measurement Data Collection for Energy Saving + ORUs-->>E2: + E2-->>NRT: 2.2 <> Measurement Data Collection for Energy Saving + NRT-->>SMO: 3 Data retrieval + + SMO->>NRT: 4.1 AI/ML Model training + NRT-->>SMO: + SMO->>NRT: 4.2 <> or <> Deploy AI/ML model + NRT-->>SMO: + + SMO->>NRT: 5.1 <> Optimization Trigger/Target + NRT-->>SMO: + SMO->>NRT: 5.2 <> A1 Policy + NRT-->>SMO: + + SMO->>NRT: 6.1 <> Data collection request for Energy Saving + NRT->>E2: 6.2 <> Data collection request for Energy Saving + E2->>ORUs: 6.3 <> Measurement Data Collection for Energy Saving + ORUs-->>E2: + E2-->>NRT: 6.4 <> Measurement Data Collection for Energy Saving + NRT-->>SMO: 6.5 AI/ML model inference + SMO->>NRT: <> E2-Node parameters configuration and actions + NRT->>E2: 6.6 for carrier(s) and cell(s) switch off/on preparation & execution and notification of execution + E2->>ORUs: 6.7 <> Update O-RU configurations and notification of update + ORUs-->>E2: + E2-->>NRT: + NRT-->>SMO: + +``` + +Sequence diagram for AI/ML inference via Near-RT RIC. The diagram shows interactions between the Service Management & Orchestration Framework (Collection & Control, Non-RT RIC) and O-RAN Nodes (Near-RT RIC, E2-Nodes, O-RUs). The process includes Data Collection, AI/ML workflow (training and deployment), Optimization Trigger and Policy, and Actor Data Collection & Decision Making. + +Figure 5.2.2.1-1: Carrier and Cell Switch Off/On flow diagram: AI/ML inference via Near-RT RIC + +#### 5.2.2.2 O-RAN Entity Roles + +##### 1) Non-RT RIC + +- a) (Optionally) Collect configurations, performance indicators and measurement reports (e.g., cell load related information and traffic information, EE/EC measurement reports, geolocation information) from SMO, E2 Nodes and O-RUs (forwarded by SMO), for the purpose of training AI/ML models that assist such EE/ES functions. +- b) (Optionally) Trigger EE/ES AI/ML model training/retraining. +- c) (Optionally) Deploy, update, configure EE/ES AI/ML models, in Near-RT RIC via O1/O2 interface. +- d) Provide optimization trigger, optimization targets and intent-based policies (e.g., set energy target to 50% of peak power consumption) to Near-RT RIC via R1/O1 or A1 interface. + +##### 2) Near-RT RIC + +- a) Collect configurations, performance indicators and measurement reports (e.g., cell load related information and traffic information, EE/EC measurement reports) from E2 Nodes. +- b) (Optionally) Receive EE/ES AI/ML model for deployment via O1 or O2 interface. +- c) Receive EE/ES related configuration management via O1 interface and/or policies via A1 interface for consideration during optimization. +- d) Analyze the received data from E2 Nodes and perform AI/ML model inference to determine EE/ES optimization (i.e. if carriers or cells are recommended to be switched off/on) considering the optimization targets/policies. +- e) Provide policies or required information to E2 Node (O-CU) via E2 to trigger actions for EE/ES optimization. + +##### 3) E2 Node + +- a) Report cell configuration, performance indicators and measurements reports (e.g., cell load related information and traffic information, EE/EC measurement reports) per cell/carrier via O1 interface to SMO and via E2 interface to Near-RT RIC. +- b) Perform actions required for EE/ES optimization + - o e.g. check ongoing emergency calls and warning messages, perform some preparation actions for Off Switching (e.g., to enable, disable, modify Carrier Aggregation and/or Dual Connectivity, to trigger HO traffic and UEs from cells/carriers to other cells or carriers, informing neighbour nodes via X2/Xn interface etc.) as well as for On Switching (e.g., cell probing, informing neighbour nodes via X2/Xn interface etc.) and make final decision on switch off/on and notify Near-RT RIC via E2 about performed actions + +##### 4) O-RU + +- a) Report EC and EE related information via Open FH M-Plane interface to O-DU or alternatively to SMO directly. +- b) Support actions required to perform EE/ES optimization. + - o updated carrier configuration (i.e. activation, deactivation or sleep) + +#### 5.2.2.3 Input/Output Data Requirements + +##### 5.2.2.3.1 Summary + +###### Input Data + +###### 1) E2 Node to SMO/Non-RT RIC (training) and Near-RT RIC (decision making/inference) + +- Carrier/cell characteristics +- EE/EC measurement reports +- Load statistics per cell and per carrier + +- UE mobility information including cell or beam level measurements (e.g., RSRP, RSRQ, SINR) +- Energy Consumption + +###### 2) O-RU to E2 Node + +- Power consumption metrics: Mean total/per carrier power consumption, mean total/per carrier transmit power + +###### Output Data + +###### 1) Near-RT RIC to E2 Node + +- Carrier(s) and/or cell(s) recommended to be switched off/on + +##### 5.2.2.3.2 Detailed Input Requirements + +Initialization: + +**Table 5.2.2.3-1: Initialization** + +| Input Data | | | | | | +|------------|-------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------|-------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing / New Definitions | +| O1 | SMO / Near-RT RIC | Optimization target for Carrier/Cell Switch Off/On | | manual or event triggered | New | +| | | E.g., (average or max) NG-RAN data Energy Efficiency | bit/J | | 3GPP TS 28.554 [7] (Cl. 6.7.1) | +| E2, O1, R1 | E2 Node (O-DU) / Near-RT RIC / SMO / rApp | Carrier/cell characteristics | - | manual or event triggered (e.g., SMO feature activation, E2 Node startup / failure / reconfig.) | New | +| | | E.g., physical location, transmit direction, carrier frequency, coverage parameters, configured transmit power, beam width, coverage shape, tilt, azimuth, carrier-cell mapping, carrier-HW mapping | | | 3GPP TS 28.541 [11] (Cl. 4.3.6, 4.3.38, 4.3.39, 4.3.40, 4.3.74)

O-RAN.WG5.O-DU-O1 (Sec. 10), O-RAN-WG5.O-CU-O1 (Sec. 9) | + +###### AI/ML Model Training: + +**Table 5.2.2.3-2: AI/ML Model Training** + +| Input Data | | | | | | +|---------------------------------------------------|-----------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------|-------|------------------------------|--------------------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing Definitions | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | DL PDCP SDU Data Volume per interface (Data Volume in DL delivered from O-CU-UP to O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.3) | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | UL PDCP SDU Data Volume per interface (Data Volume in UL delivered to O-CU-UP from O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.4) | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | RSRQ measurement per SSB per cell | dB | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.31) | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | RSRP measurement per SSB per cell | dBm | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.22) | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | SINR measurement per SSB per cell | dB | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.32) | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | Energy consumption | kWh | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.19.3) | +| O-FH (M-Plane)
or
O-FH (M-Plane),
O1, R1 | O-RU / O-DU
or
O-RU / O-DU / SMO / rApp | Power consumed by hardware component | W | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.19.2)

Reporting:
O-RAN.WG4.MP
(Sec. B.1, B.5) | +| O-FH (M-Plane)
or
O-FH (M-Plane),
O1, R1 | O-RU / O-DU
or
O-RU / O-DU / SMO / rApp | Transmit power | mW | (non-real time for training) | Measurement and reporting:
O-RAN.WG4.MP
(Sec. 10.2, B.1, B.2.1) | + +Input Decision Making / AI/ML Inference: + +**Table 5.2.2.3-3: Input Decision Making / AI/ML Inference** + +| Input Data | | | | | | +|----------------|------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|-------|------------------|--------------------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing / New Definitions | +| E2 | E2 Node (O-DU) / Near-RT RIC | Data Volume in DL delivered from O-CU-UP to O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U). In case of split gNB architecture. | Mbit | ~ per N x 100ms | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.3)

Reporting:
O-RAN.WG3.E2SM-KPM | +| E2 | E2 Node (O-DU) / Near-RT RIC | Data Volume in UL delivered to O-CU-UP from O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U). In case of split gNB architecture. | Mbit | ~ per N x 100ms | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.4)

Reporting:
O-RAN.WG3.E2SM-KPM | +| E2 | E2 Node (O-DU) / Near-RT RIC | RSRQ measurement per SSB per cell | dB | ~ per N x 100ms | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.31)

Reporting:
O-RAN.WG3.E2SM-KPM | +| E2 | E2 Node (O-DU) / Near-RT RIC | RSRP measurement based on SSB per UE | dBm | ~ per N x 100ms | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.22)

Reporting:
O-RAN.WG3.E2SM-KPM | +| E2 | E2 Node (O-DU) / Near-RT RIC | SINR measurement based on SSB per UE | dB | ~ per N x 100ms | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.32)

Reporting:
O-RAN.WG3.E2SM-KPM | +| E2 | E2 Node (O-DU) / Near-RT RIC | Energy consumption | kWh | ~ per N x 100ms | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.19.3)

New reporting: E2 | +| O-FH (M-Plane) | O-RU / O-DU | Power consumed by hardware component | W | ~ per N x 100ms | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.19.2)

Reporting:
O-RAN.WG4.MP
(Sec. B.1, B.5) | +| O-FH (M-Plane) | O-RU / O-DU | Transmit power | mW | ~ per N x 100ms | Measurement and reporting:
O-RAN.WG4.MP
(Sec. 10.2, B.1, B.2.1) | + +##### 5.2.2.3.3 Detailed Output Requirements + +Output Decision Making / AI/ML Inference: + +**Table 5.2.2.3-4: Output Decision Making / AI/ML Inference** + +| Output Data | | | | | | +|----------------|------------------------------|----------------------------------------------------------------------------------------------------------------------------------|-------|-----------------|-----------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Config. Period | Existing / New Definitions | +| E2 | Near-RT RIC / E2 Node (O-CU) | Candidate carrier(s) / cells (s) recommended for energy saving to enter energySaving state (e.g., 3GPP TS 28.310 [8] Sec. 6.2.2) | - | > min | 3GPP TS 28.541 [11] (Cl. 4.3.63)
New configuration: E2 | +| | | Candidate carrier(s) / cell (s) for compensation (e.g., 3GPP TS 32.551 [15] compensatingForEnergySaving, optional) | - | > min | - | +| E2 | E2 Node (O-CU) / Near-RT RIC | Confirmation (Success/Failure) | - | event triggered | 3GPP TS 28.310 [8] (Cl. 6.2.2) | +| O-FH (M-Plane) | E2 Node (O-DU) / O-RU | Updated carrier configuration (i.e. activation, deactivation, or sleep) | - | > min | O-RAN.WG4.MP (Sec. 15.3.2) | + +## 5.3 Impact Analysis on O-RAN Work Groups + +This is an initial impact analysis as part of the WG1 UCTG Network Energy Saving work on Carrier and Cell Switch Off/On use case. The intention is to estimate the expected standardization effort within the O-RAN work groups. It is up to the WGs to decide how Carrier and Cell Switch Off/On use case functionality should be specified in specifications of each WG. + +| # | WGs/FGs | Spec. No | Objective description | +|---|--------------------------|--------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | WG1 (Use case) | O-RAN.WG1.NES-USE-CASES-TR
O-RAN.WG1.Use-Cases-Detailed-Specification | Update WG1 NES use case analysis report and use-case detailed specification with Carrier and Cell Switch Off/On use case. No impact to existing architecture. | +| 2 | WG2 (Non-RT RIC, A1, R1) | O-RAN.WG2.R1GAP
O-RAN.WG2.R1UCR
O-RAN.WG2.R1TD (TBD) | Updates to R1 services and procedures for Carrier and Cell Switch Off/On use case | +| | | O-RAN.WG2.Non-RT-RIC-ARCH | No impact identified | +| | | O-RAN.WG2.Use-Case-Requirements | Specifying Carrier and Cell Switch Off/On use case and its requirements in WG2 UCR specification | +| | | O-RAN.WG2.A1GAP
O-RAN.WG2.A1TD | Review and implement potential requirements for policy driven implementation 2 nd deployment option of Carrier and Cell Switch Off/On use case captured in WG2 UCR specification. | +| 3 | WG3 (Near-RT RIC, E2) | O-RAN.WG3.UCR | Specifying 2 nd deployment option of Carrier and Cell Switch Off/On use case and its requirements in WG3 UCR specification | +| | | O-RAN.WG3.RICARCH | No impact identified | +| | | O-RAN.WG3.E2GAP | No impact identified | +| | | O-RAN.WG3.E2AP | No impact identified | +| | | O-RAN.WG3.E2SM-RC or
NEW: O-RAN.WG3.E2SM-CC | Identify and specify RAN E2 actions necessary for 2 nd deployment option of Carrier and Cell Switch Off/On use case through E2 Node | +| | | O-RAN.WG3.E2SM-KPM | Identify and specify RAN E2 measurement required analysis of ES and EC for 2 nd deployment option of Carrier and Cell Switch Off/On use case through Near-RT RIC | +| 4 | WG4 (O-FH) | O-RAN.WG4.MP | Review and specify requirements for M-Plane. Identify and specify relevant impacts on M-Plane for both Hierarchical and hybrid model to accommodate management features requirements towards O-RU. Define O-RU Energy efficiency KPIs and counters. | +| | | O-RAN-WG4.CUS | Review and specify requirements for CUS-Plane. Identify and specify relevant impacts on CUS Plane and data model to support various Tx/Rx Array Carrier Off/On. | +| 5 | WG5 (O1) | O-RAN.WG5.O-DU-O1
O-RAN.WG5.O-CU-O1
O-RAN.WG5.MP | Identify specific O-DU operational and data model aspects of the feature content including the interface between SMO and O-DU, and the one between SMO and O-CU. Make appropriate changes to the O-DU data model and other WG5 specifications as needed. | +| 6 | WG10 | O-RAN.WG10.O1-Interface
O-RAN.WG10.OAM-Architecture
O-RAN.WG10.Information Model and Data Models | Review, identify enhancements and update the relevant impacts on O1 interface and IM/DM to support Carrier and Cell Switch Off/On use case. | + +## 5.4 Relation and Impact on 3GPP Specifications + +### 5.4.1 Relation to 3GPP RAN Specifications + +| Specs | Release | Title | Description | +|----------------------------------|------------|------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| TR 36.927 | LTE Rel.10 | Study on Potential solutions for energy saving for E-UTRAN | Study on energy saving for E-UTRAN. | +| TS 36.300 and other specs | LTE Rel.10 | E-UTRAN; Overall description; Stage 2 |

Support of LTE energy saving by cell/carrier off/on switching. The switch-off decision might be taken by the capacity booster cell autonomously or may be centrally controlled by OAM. The eNB may initiate handover with appropriate root cause values and thereby inform its neighbour cells about the future switch off. The load of the neighbour cells may also be monitored by load information exchange over X2. Before switching off, all peer eNBs can be informed about the switch off over the X2 interface. For the switch off a Deactivation Indication was added to the ENB CONFIGURATION UPDATE procedure.

For switch on a CELL ACTIVATION REQUEST/RESPONSE procedure was introduced in LTE Rel.10. The autonomous switch on decision is more difficult to realize particularly for small cells. Even with high load on the coverage cell, it is not obvious if there are UEs in the vicinity of such small cells.

| +| TS 36.300 and other specs | LTE Rel.11 | E-UTRAN; Overall description; Stage 2 | LTE Rel.11 defined respective S1 messages for Inter-RAT (i.e. GERAN, UMTS) support. | +| TR 36.887 | LTE Rel.12 | Study on energy saving enhancement for E-UTRAN | Study on energy saving enhancements for E-UTRAN. | +| TS 36.300 and other specs | LTE Rel.15 | E-UTRAN; Overall description; Stage 2 | EN-DC CONFIGURATION UPDATE procedure was specified to support LTE-NR Dual Connectivity in the Non-Standalone Configurations. | +| TS 38.300 and other specs | 5G Rel.15 | NR and NG-RAN Overall description; Stage-2 | Support of 5G energy saving by cell/carrier off/on switching. Similar functionality as defined for LTE. E-UTRA or NR cell providing additional capacity via single or dual connectivity. | + +### 5.4.2 Ongoing Work in 3GPP Rel.18 RAN + +The following study is conducted in 3GPP Rel.18 in RAN. This includes: + +- Definition of a base station energy consumption model +- Definition of an evaluation methodology and KPIs +- Study and identify techniques on the gNB and UE side to improve network energy savings in terms of both BS transmission and reception + +| Reference | Release | Title | Documentation and impact on Specifications | +|-------------------|-----------|----------------------------------------|--------------------------------------------------| +| FS_Netw_Energy_NR | 5G Rel.18 | Study on network energy savings for NR | Results will be captured in 3GPP TR 38.864 [19]. | + +While 3GPP RAN WG1 is leading this study item, RAN WG3 will study aspects of information exchange/coordination over network interfaces such as X2/Xn. For this purpose, RAN WG3 also considers Enhanced Carrier/Cell Switch Off/On mechanisms. + +### 5.4.3 Impact on 3GPP RAN Specifications + +Non-RT or Near-RT RIC controlled Cell Switch Off/On is not considered to have any impact on 3GPP RAN specifications. + +### 5.4.4 Relation to 3GPP System Architecture Specifications + +| Specs | Release | Title | Description | +|----------------------------------|------------|------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| TR 36.927 | LTE Rel.10 | Study on Energy Savings Management | Study on Energy Savings Management | +| TS 32.551 and other specs | LTE Rel.10 | Energy Saving Management (ESM); Concepts and requirements | Concepts and requirements for ESM. According to 3GPP TS 32.551, the energy saving procedure initiating capacity booster cell, to enter or exit “energySaving” state, should be able to initiate energy saving compensation activation and/or deactivation on one or multiple cells or network elements. 3GPP TS 32.425 [13] defines the measurements and 3GPP TS 32.451 [14] defines the KPIs. | +| TR 32.834 | LTE Rel.11 | Study on OAM aspects of inter-RAT Energy Saving | Inter-RAT aspects of Energy Saving. The following RATs are considered in this study: GSM, UMTS, LTE, CDMA. | +| TR 23.866 | LTE Rel.12 | Study on System Enhancements for Energy Efficiency | Study on System Enhancements for Energy Efficiency | +| TR 32.856 | 5G Rel.15 | Study on OAM support for assessment of energy efficiency in mobile access networks | Support for ETSI metrics and methods for energy efficiency assessment and related measurements. Principles for monitoring equipment power, energy and environmental parameters. 2G, 3G and 4G have been covered. | +| TS 28.310 and other specs | 5G Rel.16 | Energy efficiency of 5G |

This TS defines solutions and requirements for

  • - Data Volume collection Power,
  • - Power, Energy and Environmental (PEE) measurement collection
  • - Energy Saving use cases

The Energy Saving use case defines the scenario of energy saving by switching off capacity booster cells when the traffic demand is low and re-activate them on a need basis. The energy saving consists of two scenarios where the capacity booster cell gNB is fully or partially overlaid by the candidate cell(s).

The configuration of energy saving policies for these solutions is defined in 3GPP TS 28.541 [11]. The measurements related to data volume and PEE measurements are defined in 3GPP TS 28.552 [12]. The Energy Efficiency related KPIs are defined in TS 28.554 [7].

| + +### 5.4.5 Ongoing Work in 3GPP Rel.18 System Architecture + +Energy saving compensation activation and deactivation procedures for LTE are defined in 3GPP TS 32.551 [15] as: + +- Energy saving compensation activation: procedure to increase the coverage area for the candidate cell(s). +- Energy saving compensation deactivation: procedure to decrease a previously increased coverage area. + +This procedure is not defined yet for energy saving procedures for 5G, and hence 3GPP TS 28.310 [8] needs to be enhanced to introduce this procedure for 5G networks. Related study and work items are existing. + +| Reference | Release | Title | Documentation and impact on Specifications | +|---------------------|-----------|----------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------| +| FS_EE5G_Ph2 | 5G Rel.18 | Study on new aspects of EE for 5G networks Phase 2 | Results will be captured in 3GPP TR 28.913 Study on new aspects of EE for 5G networks phase 2. | +| EE5GPLUS_Ph2 | 5G Rel.18 | Enhancements of EE for 5G Phase 2 | Specification enhancements are expected for the following 3GPP specifications: TS 28.310 [8], TS 28.552 [12], TS 28.554 [7] and TS 28.541 [11]. | + +### 5.4.6 Impact on 3GPP System Architecture Specifications + +Non-RT or Near-RT RIC controlled Cell Switch Off/On is not considered to have any impact on 3GPP System Architecture specifications. + +## 5.5 Gain Analysis + +An operator can expect strong energy savings, and thus OPEX savings, by using Carrier/Cell Switching in a network with multiple frequency layers. The exact power saving strongly depends on network deployment details, cell configuration (e.g., configured bandwidth, common channels etc.), used hardware, and network load. Multiple frequency layers may or may not use the same power amplifier in the RF module. Major power savings are naturally obtained when some power amplifiers can be switched off completely. + +Numerical analysis based on an estimated power saving per carrier / cell to be switched off might provide a good estimate of the expected savings. O-RU power consumption might be categorized into power consumption related to: + +1. user channels' load (e.g., traffic on uplink/downlink shared channels), +2. common signals and channels' load (e.g., SSB transmissions, Reference Signals, broadcast channel, paging channel etc.), +3. regular PA operational power (i.e., the required energy to power up the power amplifier), +4. regular operational power (i.e., the required energy to power up the radio module). + +Power consumption related to (1), (2) and (3) scales with the number of transmission paths as illustrated in Figure 5.5-1. + +![Figure 5.5-1: O-RU power saving for a 4TX4RX sector configuration. The figure consists of two side-by-side bar charts. The left chart, titled 'Transmitted Power (Normal Mode)', shows four stacked bars representing power consumption in Watts (W). Each bar is divided into four segments labeled 1, 2, 3, and 4 from top to bottom. Segment 1 is the top-most, followed by 2, 3, and 4 at the base. An arrow labeled 'TX path' points to the top of the first bar. The right chart, titled 'Transmitted Power (Power Saving Mode)', shows a single bar with segment 4 at the base, indicating that only the power consumption of segment 4 remains during power saving mode.](821a20f64ac189eef89f204d3697c3e3_img.jpg) + +Figure 5.5-1: O-RU power saving for a 4TX4RX sector configuration. The figure consists of two side-by-side bar charts. The left chart, titled 'Transmitted Power (Normal Mode)', shows four stacked bars representing power consumption in Watts (W). Each bar is divided into four segments labeled 1, 2, 3, and 4 from top to bottom. Segment 1 is the top-most, followed by 2, 3, and 4 at the base. An arrow labeled 'TX path' points to the top of the first bar. The right chart, titled 'Transmitted Power (Power Saving Mode)', shows a single bar with segment 4 at the base, indicating that only the power consumption of segment 4 remains during power saving mode. + +**Figure 5.5-1: O-RU power saving for a 4TX4RX sector configuration** + +Considering that the requested traffic (1) needs to be transmitted in one of the remaining carriers/cells and that regular operational power (4) will be required after carrier/cell switch off, the power savings of the Carrier/Cell Switch algorithm is mainly related to the power consumption of (2) and (3). + +The yearly energy savings might be calculated as follows: + +$$YearlyPowerSaving[MWh] = \frac{O-RU\ PowerSaving[W]}{1.000.000} * \frac{PowerSavingHours[h]}{day} * \#days * \#O-RUs$$ + +Two example calculations, simplifying the factors as cited above and ignoring deployment, cell configuration, hardware specifics and load dependencies, are provided in the table below: + +**Table 5.5-1: Simplified power savings calculation examples** + +| Factor | Value | Value | +|---------------------------------------|-------|-------| +| O-RU power savings during switch off | 100 W | 200 W | +| Number of hours of switch off per day | 2 | 4 | +| Number of O-RUs | 10000 | 20000 | +| Yearly energy saving [MWh] | 730 | 5840 | + +To be more specific considering deployment, cell configuration, antenna type, hardware and load dependencies of the O-RU power consumption, computational analysis results for two example scenarios are provided. The calculations are based on the load profile and the power consumption categorization of O-RU functional blocks as outlined in Annex B. + +Energy savings gain from Carrier and Cell Switch Off/On would be equivalent to power consumption of the O-RU hardware components that can be shut down or put into energy savings mode during low traffic load. As illustrated in Figure 5.5-2, major energy savings gain would be derived from shutting down RF Processing Unit and Digital Processing Unit (depending on the antenna configuration), while FH Processing Unit, Power Unit and other components would still be fully or partially functioning, and the power consumption would stay more or less consistent during the switching off period. + +![Figure 5.5-2: Energy savings for O-RU. The diagram shows the internal components of an O-RU7-2. It includes an O-RAN FH block, an eCPRI block, a Digital Processing Unit, and an RF Processing Unit. These are connected to a Timing Unit and a Power Unit. The Timing Unit receives local timing from CDR and GNSS (optional). The Power Unit provides power to the Timing Unit and the RF Processing Unit. The O-RAN FH block is connected to To/From O-DU7-2. The eCPRI block is connected to the Digital Processing Unit. The Digital Processing Unit is connected to the RF Processing Unit. The Timing Unit is connected to the eCPRI block, the Digital Processing Unit, and the Power Unit. The Power Unit is connected to the Timing Unit and the RF Processing Unit.](5818dc6b386a994b6de98b5085d16ce5_img.jpg) + +Figure 5.5-2: Energy savings for O-RU. The diagram shows the internal components of an O-RU7-2. It includes an O-RAN FH block, an eCPRI block, a Digital Processing Unit, and an RF Processing Unit. These are connected to a Timing Unit and a Power Unit. The Timing Unit receives local timing from CDR and GNSS (optional). The Power Unit provides power to the Timing Unit and the RF Processing Unit. The O-RAN FH block is connected to To/From O-DU7-2. The eCPRI block is connected to the Digital Processing Unit. The Digital Processing Unit is connected to the RF Processing Unit. The Timing Unit is connected to the eCPRI block, the Digital Processing Unit, and the Power Unit. The Power Unit is connected to the Timing Unit and the RF Processing Unit. + +**Figure 5.5-2: Energy savings for O-RU** + +### 5.5.1 Cell and Carrier Switch Off/On Energy Saving for 4T4R O-RU + +The energy saving gain from Carrier and Cell Switch Off/On is analyzed based on the system parameters in Table 5.5.1-1 and the example power profile considering power consumption from operational experience provided in Table 5.5.1-2. + +**Table 5.5.1-1: O-RU Configuration for ES gain analysis** + +| | | +|-----------------------------|---------| +| No. of antennas | 4T4R | +| No. of layers | 4 | +| Bandwidth | 100 MHz | +| Carrier frequency | 3.5 GHz | +| Tx power per antenna | 30 W | +| Technology | 5G NR | + +**Table 5.5.1-2: Example power profile for 4T4R O-RU** + +| Operating Load (Traffic) | Total O-RU (W) | ORAN Fronthaul Processing Unit (W) | Digital Processing Unit (W) | RF Processing Unit (W) | Power Unit & other components (W) | +|---------------------------------|-----------------------|-------------------------------------------|------------------------------------|-------------------------------|----------------------------------------------| +| Busy hour load | 550 | 10 | 25 | 495 | 20 | +| Low load | 200 | 10 | 25 | 145 | 20 | +| Sleep (Energy Savings State) | 50 | 5~10 | 0~5 | 0~15 | 15~20 | +| Energy saving gain | 150~180 | 0~5 | 20~25 | 130~145 | 0~5 | + +Compared to the low load scenario, energy savings of up to 150~180 W per O-RU can be achieved in the energy saving state. An example calculation for yearly energy saving potential considering a shutdown of 10000 O-RUs during 3 hours per day is provided in Table 5.5.1-3. + +**Table 5.5.1-3: Power saving calculation example for 4T4R O-RU** + +| Factor | Value | +|----------------------------------------------------------------|-----------| +| O-RU power savings during switch off (low load) [W] | 150~180 | +| Number of hours of switch off per day (50% of low load period) | 3 | +| Number of O-RUs | 10000 | +| Yearly energy saving [MWh] | 1643~1971 | + +### 5.5.2 Cell and Carrier Switch Off/On Energy Saving for 64T64R O-RU + +The energy saving gain from Carrier and Cell Switch Off/On is analyzed based on the system parameters in Table 5.5.2-1 and the example power profile considering power consumption from operational experience provided in Table 5.5.2-2. + +**Table 5.5.2-1: O-RU Configuration for ES gain analysis** + +| | | +|----------------------|---------| +| No. of antennas | 64T64R | +| No. of layers | 16 | +| Bandwidth | 100 MHz | +| Carrier frequency | 3.5 GHz | +| Tx power per antenna | 30 W | +| Technology | 5G NR | + +**Table 5.5.2-2: Example power profile for 64T64R O-RU** + +| Operating Load (Traffic) | Total O-RU (W) | ORAN Fronthaul Processing Unit (W) | Digital Processing Unit (W) | RF Processing Unit (W) | Power Supply & other components (W) | +|------------------------------|----------------|------------------------------------|-----------------------------|------------------------|-------------------------------------| +| Busy hour load | 1100 | 50 | 200 | 800 | 50 | +| Low load | 400 | 50 | 200 | 100 | 50 | +| Sleep (Energy Savings State) | 60~140 | 30~50 | 0~20 | 0~20 | 30~50 | +| Energy saving gain | 260~340 | 0~20 | 180~200 | 80~100 | 0~20 | + +Compared to the low load scenario, energy savings of 260-340 W per O-RU can be achieved in the energy saving state. Example calculations for yearly energy saving potential considering a shutdown of 10000 O-RUs during 3 hours per day are provided in Table 5.5.2-3. + +**Table 5.5.2-3: Power saving calculation examples for 64T64R O-RU** + +| Factor | Value | +|----------------------------------------------------------------|-----------| +| O-RU power savings during switch off (low load) [W] | 260~340 | +| Number of hours of switch off per day (50% of low load period) | 3 | +| Number of O-Rus | 10000 | +| Yearly energy saving [MWh] | 2847~3723 | + +## 5.6 Feasibility Analysis + +No challenges concerning feasibility have been identified during the pre-normative phase. + +# 6 RF Channel Reconfiguration + +## 6.1 Problem Statement, Solution and Value Proposition + +In mobile networks mMIMO antennas are used for beamforming techniques to enhance cell capacity and throughput. In order to achieve beamforming, O-RUs need to concentrate the power amplifiers at the radome by combining radiating elements. At low load, i.e., when the expected traffic volume or number of connected users are lower than the configured threshold, ES can be achieved by reducing the power consumption of O-RUs by switching off certain Tx/Rx arrays. For example, 32 out of 64 Tx/Rx Arrays of an O-RU can be switched off in a digital mMIMO architecture and correspondingly the number of spatial layers and SSBs can be reduced. The procedure (involvement of respective O-RAN interfaces) of the RF Channel Reconfiguration depends on the management architecture model (hybrid or hierarchical) and the deployment option. The reconfiguration decision can be made by an AI/ML model within the inference host deployed at the Non-RT RIC (denoted as deployment Option 1), or at the Near-RT RIC (denoted as deployment option 2). Among others the AI/ML models may include prediction of future traffic, user mobility, and resource usage and may also predict expected energy efficiency enhancements, resource usage, and network performance for different ES optimization states. + +The main aim of RF Channel Reconfiguration is to perform O-RU Tx/Rx Array selection. However, Tx/Rx Array reselection may require modifying the maximum number of spatial streams, the number of SSB Beams or the O-RU Antenna transmit power. Hence the overall scope of RF Channel Reconfiguration includes the actions listed in Table 6.1-1. + +**Table 6.1-1: Actions in the context of RF Channel Reconfiguration** + +| Action Name | Explanation | Possible Implementation Method | +|---------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| O-RU Tx/Rx Array selection |

O-RU Tx/Rx Array selection means switching off certain Tx/Rx Arrays or Array elements to reduce power consumption of O-RU.

Reselecting Rx/Tx Arrays may impact cell coverage.

|
  • – O-RU reports all supported Tx/Rx Array selections to O-DU or to SMO via Open FH M-Plane.
  • – Based on traffic load and user distribution the Non-RT/Near RT RIC will optimize Tx/Rx Array selection.
| +| Modification of number of SU/MU MIMO spatial streams or data layers |

The maximum number of spatial streams may depend on the O-RU Tx/Rx Array selection, and it may be necessary to be modified along with a new Tx/Rx Array selection.

A reduction of the number of spatial streams without Tx/Rx Array selection is not excluded as in certain scenarios the energy consumption of O-RU and/or O-DU may be reduced by turning off certain processing units of FPGA/GPUs, by running at a lower clock speed or turning off CPU/GPU cores along with reduced processing requirements.

|
  • – O-RU may report the maximum number of supported spatial streams for each Tx/Rx Array selection. For example, 16 spatial streams for 64 Tx/Rx and 8 spatial Layers for 32 Tx/Rx.
  • – Based on the traffic load and the user distribution the O-RU will be instructed about the maximum number of spatial streams to be used. Hence, the O-RU and/or O-DU may be able turn off certain processing units that would be required to processing a higher number of spatial streams.
| +| Modification of the number of SSB beams |

The number of SSB beams may depend on the O-RU Tx/Rx Array selection and the number of spatial streams. Hence it may be necessary to adapt the number of SSB beams.

|
  • – The number of SSB beams is controlled by the O-DU. Hence the O-DU can be instructed via Non-RT/Near-RT RIC to set the number of SSB beams based on Tx/Rx Array selection.
| +| Modify the O-RU Antenna Transmit power |

The maximum O-RU total transmit power may depend upon the O-RU Tx/Rx Array selection; hence it may need to be modified along with Tx/Rx Array selection to compensate for reduced coverage in the downlink.

|
  • – The O-RU power is configured per Tx Array. Hence, the modification may not be required when O-RU Tx/Rx Array selection from 64 Tx/Rx to 32 Tx/Rx. However, if possible, O-RU Tx power can be increased to compensate for reduced coverage.
| + +## 6.2 Architecture/Deployment Options + +### 6.2.1 Option 1: Non-RT RIC Deployment + +In option 1, decision making, potentially including AI/ML Model Training and Inference, is done at the Non-RT RIC. + +#### 6.2.1.1 Description and UML Diagram + +**Table 6.2.1.1-1: RF Channel Reconfiguration: AI/ML inference via Non-RT RIC** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Enable RF Channel Reconfiguration Energy Saving functions in the Network by means of configuration parameter change and actions controlled by Non-RT RIC to enable AI/ML-based solutions. | | +| Actors and Roles | Non-RT RIC acting as inference host for Energy Savings decision making.
E2 Node and O-RU are the subject of action for configuration enforcement. | | +| Assumptions | O1 interface connectivity is established between E2 Nodes and SMO.
Open FH M-Plane interface is established between E2 Node and O-RU or between O-RU and SMO.
Network is operational. | | +| Pre-conditions | The operator has set the targets for Energy Saving functions in the Non-RT RIC (rApp).
Capability of O-RU to support various RF Channel Reconfiguration actions. | | +| Begins when | The operator enables the optimization functions for RF Channel Reconfiguration Energy Saving and E2 Node and O-RU become operational | | +| Steps 1.1, 1.2, 1.3, 1.4 (M) | Non-RT RIC initiates specific measurement data collection request through SMO via O1 towards E2 Node or via Open FH M-Plane directly towards O-RU for AI/ML model training for Energy Saving optimization | | +| Steps 2.1, 2.2, 2.3, 2.4 (M) | E2 Node and O-RU send the configured measurement data to SMO periodically or event based for Non-RT RIC processing. Non-RT RIC retrieves data through SMO from E2 Node and from O-RU. | | +| Step 3 (M) | Non-RT RIC retrieves the collected measurement data for processing. | | +| Steps 4.1, 4.2, 4.3 (M) | Non-RT RIC trains the AI/ML models with the collected data. Trained AI/ML models are deployed and activated in the Non-RT RIC.

Non-RT RIC constantly monitors performance and energy consumption of the E2 Node and the O-RU for inference, such as cell load related and traffic information, EE/EC measurement reports, geolocation information etc. | | +| Step 5 (M) | Based on the AI/ML inference, the Non-RT RIC may request the SMO to configure E2 Node (O-DU) and execute RF Channel Reconfiguration for ES/EE optimization. | | +| Steps 6.1, 6.2, 6.3, 6.4 (M) | SMO instructs E2 Node via O1 to perform the received request(s) from Non-RT RIC
  • i. O-RU Tx/Rx Array selection.
  • ii. Modify the number of SU/MU MIMO spatial streams or data layers.
  • iii. Modify the number of SSB beams.
  • iv. Modify O-RU Antenna Transmit power.
| | +| Step 7 (M) | Non-RT RIC continuously monitors the performance of AI/ML model. If energy saving objectives are not achieved, it may decide to initiate fallback mechanism, and/or AI/ML model update or retraining. | | +| Ends when | If E2 Node becomes non-operational or when the operator disables the optimization functions for Energy Saving. | | +| Exceptions | None | | +| Post Conditions | Non-RT RIC continues closed loop monitoring of Energy Saving function for E2 Node and O-RU.
E2 Node and O-RU operate using the newly deployed parameters and state. | | + +``` + +@startuml +skinparam defaultFontSize 12 +autonumber +Box "Service Management & \n Orchestration Framework" #gold +Participant "Collection & Control" as smo +Participant " Non-RT RIC" as NRTRIC +End box +Box "O-RAN Nodes" #lightpink + Participant "Near-RT RIC" as RTRIC + Participant "E2-Node" as E2NODES + Participant "O-RU" as ORUs +End box + +autonumber 1.1 +group Data Collection +alt via O1 +smo -> E2NODES : <> Data collection request for Energy Saving +E2NODES -> ORUs : <> Data collection request +Else via OFH-MP +smo -> E2NODES : <> Data collection request for Energy Saving +smo -> ORUs : <> Data collection request +end + +autonumber 2.1 +alt Via O1 +ORUs -> E2NODES : <> Measurement Data Collection +E2NODES -> smo : <> Measurement Collection for Energy Saving +Else via OFH-MP +ORUs -> smo : <> Measurement Data Collection +E2NODES -> smo : <> Measurement Collection for Energy Saving +End +autonumber 3 +smo -> NRTRIC : <> Data Retrieval +end + +group Data Analysis Training and Inference +autonumber 4.1 + NRTRIC -> NRTRIC : AI/ML Model training + NRTRIC -> NRTRIC : Deploy & activate trained AI/ML Model for inferencing + NRTRIC -> NRTRIC : Monitoring & Analysis of Energy Efficiency \n & Consumption (E2 +Node & O-RU) +autonumber 5 +group Actor Decision Making + + NRTRIC -> smo : Request to prepare and execute RF Channel Reconfiguration +\nenforcement for Energy saving +autonumber 6.1 + +smo -> E2NODES : <> RF Channel Reconfiguration enforcement for Energy saving +E2NODES -> ORUs : <> Updated O-RU Configurations + +end +autonumber 7 + NRTRIC -> NRTRIC : Performance analysis of AI/ML model \n(with possible actions, e.g. +fallback, re-training) +end +@enduml + +``` + +![Sequence diagram for RF Channel Reconfiguration flow diagram: AI/ML inference in Non-RT RIC. The diagram shows interactions between the Service Management & Orchestration Framework (SMO) and O-RAN Nodes (Near-RT RIC, E2-Node, O-RU).](855e6df9dae27be31f76f8e0c069cd12_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management & Orchestration Framework + participant NearRT as Near-RT RIC + participant E2Node as E2-Node + participant ORU as O-RU + + SMO->>NearRT: 1.1 <> Data collection request for Energy Saving + Note over SMO: [via O1] + NearRT->>E2Node: 1.2 <> Data collection request + Note over E2Node: [via OFH-MP] + E2Node->>ORU: 1.3 <> Data collection request for Energy Saving + Note over ORU: 1.4 <> Data collection request + ORU-->>E2Node: 2.1 <> Measurement Data Collection + E2Node-->>NearRT: 2.2 <> Measurement Collection for Energy Saving + Note over SMO: [via O1] + NearRT-->>SMO: 2.3 <> Measurement Data Collection + Note over SMO: [via OFH-MP] + SMO-->>NearRT: 2.4 <> Measurement Collection for Energy Saving + NearRT->>SMO: 3 <> Data Retrieval + + SMO->>NearRT: 4.1 AI/ML Model training + Note over SMO: 4.2 Deploy & activate trained AI/ML Model for inferecing + Note over SMO: 4.3 Monitoring & Analysis of Energy Efficiency & Consumption (E2 Node & O-RU) + + SMO->>NearRT: 5 Request to prepare and execute RF Channel Reconfiguration enforcement for Energy saving + Note over SMO: 6.1 <> RF Channel Reconfiguration enforcement for Energy saving + NearRT->>E2Node: 6.2 <> Updated O-RU Configurations + E2Node->>ORU: 6.2 <> Updated O-RU Configurations + + SMO->>NearRT: 7 Performance analysis of AI/ML model (with possible actions, e.g. fallback, re-training) + Note over SMO: 7 Performance analysis of AI/ML model (with possible actions, e.g. fallback, re-training) + +``` + +Sequence diagram for RF Channel Reconfiguration flow diagram: AI/ML inference in Non-RT RIC. The diagram shows interactions between the Service Management & Orchestration Framework (SMO) and O-RAN Nodes (Near-RT RIC, E2-Node, O-RU). + +Figure 6.2.1.1-1: RF Channel Reconfiguration flow diagram: AI/ML inference in Non-RT RIC + +#### 6.2.1.2 O-RAN Entity Roles + +##### 1) SMO (including Non-RT RIC) + +- a) Collect necessary cell configurations, performance indicators and measurement reports (e.g., cell load related and traffic information, EE/EC measurement reports, geolocation information) from E2 Node and O-RU, for the purpose of training and inference of AI/ML models that assist in the EE/ES functions. +- b) Trigger EE/ES AI/ML model training/retraining. +- c) Deploy, update, and configure EE/ES AI/ML models +- d) Analyze the data received from E2 Nodes and O-RU to determine RF Channel Reconfiguration actions for EE/ES, i.e., O-RU Tx/Rx Array selection, modification of the number of SSB beams, modification of the O-RU Antenna Transmit power, modification of the number of SU/MU MIMO spatial streams or data layers using AI/ML models. +- e) Signal updated RF Channel Reconfiguration and execution of optimization actions to E2 Node via O1 Interface. + +##### 2) E2 Node + +- a) Report necessary cell configurations, performance indicators, and measurement reports (e.g., cell load related and traffic information, EE/EC measurement reports) to SMO via O1 interface. +- b) Perform actions required to perform RF Channel Reconfiguration (i.e., O-RU Tx/Rx Array selection, modification of the number of SSB beams, modification of the O-RU Antenna Transmit power, modification of the number of SU/MU MIMO data layers or spatial streams) as part of EE/ES optimization. + +##### 3) O-RU + +- a) Report EC and EE related information over Open FH M-Plane to O-DU or alternatively to SMO directly. +- b) Perform actions required to be performed due to RF Channel Reconfiguration (i.e., O-RU Tx/Rx Array selection, modification of the number of SSB beams, modification of the O-RU Antenna Transmit power, modification of the number of SU/MU MIMO spatial streams or data layers) as part of EE/ES optimization. + +#### 6.2.1.3 Input/Output Data Requirements + +##### 6.2.1.3.1 Summary + +###### Input Data + +###### 1) SMO and E2 Node + +- Load statistics per cell and per carrier, such as number of active users, average number of RRC connections, average number of scheduled active users per TTI, PRB utilization, DL/UL Cell/User throughput, PMI/CSI reports. +- Latency statistics per cell (if URLLC slices are involved, latency is used in the EE definition, 3GPP TS 28.554 [7]). + +###### 2) O-RU + +- Power consumption metrics: Mean total/per carrier power consumption, mean total/per carrier transmit power. +- Information on supported Tx/Rx Array selections along with power consumption (site/O-RU input power needed for certain EE KPIs) + +###### Output Data + +###### 1) SMO to E2 Node + +- RF Channel Reconfiguration actions which can include, + - O-RU Tx/Rx Array selection + - Modify the number of SU/MU MIMO spatial streams or data layers + - Modify the number of SSB beams + - Modify O-RU Antenna Transmit power + +##### 6.2.1.3.2 Detailed Input Requirements + +Initialization: + +**Table 6.2.1.3-1: Initialization** + +| Input Data | | | | | | +|------------------------------------------|-----------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------|---------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing / New Definitions | +| R1 | SMO / rApp | Optimization target for RF Channel Reconfiguration | - | manual or event triggered | New | +| | | E.g., (average or max) NG-RAN data Energy Efficiency | bit/J | | 3GPP TS 28.554 [7] (Cl. 6.7.1) | +| R1 | SMO / rApp | Maximum Initial Access Latency for given SSB Beam Configuration | ms | Initialization | New: KPI metric input by the operator | +| O1, R1 | O-DU / SMO / rApp | Carrier/cell characteristics | - | manual or event triggered (e.g., SMO feature activation, E2 Node startup/failure/reconfig.) | New | +| | | E.g., physical location, transmit direction, carrier frequency, coverage parameters, configured transmit power, beam width, coverage shape, tilt, azimuth, carrier-cell mapping, carrier-HW mapping | - | | 3GPP TS 28.541 [11] (Cl. 4.3.6, 4.3.38, 4.3.39, 4.3.40, 4.3.74)

O-RAN.WG5.O-DU-O1 (Sec. 10), O-RAN-WG5.O-CU-O1 (Sec. 9) | +| O-FH (M-Plane) or O-FH (M-Plane), O1, R1 | O-RU / O-DU or O-RU / O-DU / SMO / rApp | Supported common beam configuration from O-RU per cell | file | Initialization | O-RAN.WG5.MP (Sec. 8.1) | +| O-FH (M-Plane) | O-RU / O-DU | Beamforming weights or attributes via YANG module per cell | values in IE | Initialization | O-RAN.WG4.CUS (Sec. 12.4.2) | +| R1, O1, O-FH (M-Plane) or O-FH (M-Plane) | rApp / SMO / O-DU / O-RU or O-DU / O-RU | Inferred SSB beam configuration in specified file per cell | file | Initialization | O-RAN.WG4.CUS (Sec. 12.4.2) | +| O1, R1 | O-DU / SMO / rApp | Supported SSB and CSI-RS TRS configurations per cell | - | Initialization | 3GPP TS 38.331 [16] (Sec. 6.3.2) | + +| | | | | | | +|------------------------|--------------------------|---------------------------------------|--------------|----------------|--------------------------------------------------------------------------------------------------------------------------| +| O-FH (M-Plane), O1, R1 | O-RU / O-DU / SMO / rApp | O-RU reports all offered Tx/Rx Arrays | file | Initialization |

New Definition required in O-RAN.WG5.MP

o-ran-uplane-conf.yang module

o-ran-beamforming.yang module

| +| O-FH (M-Plane) | O-RU / O-DU | O-RU reports all offered Tx/Rx Arrays | values in IE | Initialization |

New Definition required in O-RAN.WG4.MP

o-ran-uplane-conf.yang module

o-ran-beamforming.yang module

| + +###### AI/ML Model Training: + +**Table 6.2.1.3-2: AI/ML Model Training** + +| Input Data | | | | | | +|------------------------------------------|-----------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|------------------------------|-------------------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing / New Definitions | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | DL PDCP SDU Data Volume per interface (Data Volume in DL delivered from O-CU-UP to O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.3) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | UL PDCP SDU Data Volume per interface (Data Volume in UL delivered to O-CU-UP from O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.4) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Number of active UEs in NG-RAN (Number of RRC_CONNECTED UEs) per cell | Integer | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Sec. 5.1.1.23, A7, A.60) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | RSRQ measurement per SSB per cell | dB | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.31) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | RSRP measurement per SSB per cell | dBm | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.22) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | SINR measurement per SSB per cell | dB | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.32) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Energy consumption | kWh | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.19.3) | +| O-FH (M-Plane) or O-FH (M-Plane), O1, R1 | O-RU / O-DU or O-RU / O-DU / SMO / rApp | Power consumed by O-RU or its hardware components | W | (non-real time for training) | Measurement:
3GPP TS28.552 [12]
(Cl. 5.1.1.19.2)

Reporting:
O-RAN.WG4.MP
(Sec. B.1, B.5) | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | Over the air transmit power by O-RU as calculated in O-DU

Note: This measurement is required to calculate energy efficiency of O-RU. | W | (non-real time for training) | New Measurement and New Reporting required in O-RAN.WG5.MP | + +Input Decision Making / AI/ML Inference: + +**Table 6.2.1.3-3: Input Decision Making / AI/ML Inference** + +| Input Data | | | | | | +|------------------------------------------|-----------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|------------------------------|--------------------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing / New Definitions | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | DL PDCP SDU Data Volume per interface (Data Volume in DL delivered from O-CU-UP to O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.3) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | UL PDCP SDU Data Volume per interface (Data Volume in UL delivered to O-CU-UP from O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.3.6.2.4) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Number of active UEs in NG-RAN (Number of RRC_CONNECTED UEs) per cell | Integer | > min | Measurement:
3GPP TS 28.552 [12]
(Sec. 5.1.1.23, A.7, A.60) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | RSRQ measurement per SSB per cell | dB | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.31) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | RSRP measurement per SSB per cell | dBm | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.22) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | SINR measurement per SSB per cell | dB | > min | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.32) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Energy consumption | kWh | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.19.3) | +| O-FH (M-Plane) or O-FH (M-Plane), O1, R1 | O-RU / O-DU or O-RU / O-DU / SMO / rApp | Power consumed by O-RU or its hardware components | W | (non-real time for training) | Measurement:
3GPP TS 28.552 [12]
(Cl. 5.1.1.19.2)

Reporting:
O-RAN.WG4.MP
(Sec. B.1, B.5) | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | Over the air transmit power by O-RU as calculated in O-DU

Note: This measurement is required to calculate energy efficiency of O-RU. | W | (non-real time for training) | New Measurement and New Reporting required in O-RAN.WG5.MP | + +##### 6.2.1.3.3 Detailed Output Requirements + +Output Decision Making / AI/ML Inference: + +**Table 6.2.1.3-4: Output Decision Making / AI/ML Inference** + +| Output Data | | | | | | +|----------------|-----------------------------|----------------------------------------------------------------------------------------------------|-------|------------------|---------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing / New Definitions | +| O-FH (M-Plane) | O-DU / O-RU | Candidate O-RU's appropriate array selection | - | > min | O-RAN.WG4.MP
o-ran-uplane-conf.yang | +| | | Maximum number of Max SU/MU MIMO spatial streams or data layers | - | > min | New Definition required in O-RAN.WG4.MP | +| | | Recommended O-RU Antenna Transmit power | W | > min | O-RAN.WG4.MP
urn:o-ran:uplane-conf
Module gain | +| R1, O1 | rApp / SMO / O-DU | Candidate O-RU's appropriate array selection | - | > min | New Definition required in WG2 R1 and O-RAN.WG5.O-DU-O1 | +| | | Maximum number of Max SU/MU MIMO spatial streams or data layers | - | > min | New Definition required in O-RAN.WG4.MP | +| | | Inferred O-RU SS Burst Set (SS Block Number and SS Burst Periodicity) and CSI-RS TRS Configuration | - | Initialization | 3GPP TS 38.331 [16]
IE:
ServingCellConfigCommon | +| | | Recommended O-RU Antenna Transmit power | W | > min | O-RAN.WG4.MP
urn:o-ran:uplane-conf
Module gain | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | Confirmation (Success/Failure) | - | event triggered | New | + +### 6.2.2 Option 2: Near-RT RIC Deployment + +In option 2, decision making, potentially using AI/ML Model Inference, is done at Near-RT RIC. While AI/ML Model training might be hosted in the Non-RT or in the Near-RT RIC, the description below is based on AI/ML Model Training in the Non-RT RIC. + +#### 6.2.2.1 Description and UML Diagram + +**Table 6.2.2.1-1: RF Channel Reconfiguration: AI/ML inference via Near-RT RIC** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|----------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Enable RF Channel Reconfiguration Energy Saving functions in the Network by means of configuration parameter change and actions controlled by Near-RT RIC and allow for AI/ML-based solutions. | | +| Actors and Roles | Near-RT RIC acting as inference host for Energy Savings decision making. E2 Node and O-RU are the subject of action for configuration enforcement. SMO/Non-RT RIC acting as policy maker or trigger for ES optimization in Near-RT RIC. | | +| Assumptions | O1 interface connectivity is established between E2 Node, Near-RT RIC, and SMO.
E2 interface connectivity is established between E2 Node and Near-RT RIC.
A1 interface is established between Non-RT RIC and Near-RT RIC.
Open FH M-Plane interface is established between E2 Node and O-RU or between O-RU and SMO.
Network is operational. | | +| Pre-conditions | The operator has set the targets for the Energy Saving function in the Non-RT RIC (rApp).
Capability of O-RU for various RF Channel Reconfiguration actions. | | +| Begins when | Operator enables the optimization functions for RF Channel Reconfiguration Energy Saving and E2 Node and O-RU become operational. | | +| Steps 1.1, 1.2, 1.3 (M) | SMO initiates specific measurement data collection request towards E2 Node and O-RU for AI/ML model training for Energy Saving optimization. | | +| Steps 2.1, 2.2, 2.3, 2.4 (M) | E2 Node and O-RU send the configured measurement data to SMO periodically or event based for Non-RT RIC processing. | | +| Step 3 (M) | Non-RT RIC retrieves the collected measurement data for processing. | | +| Steps 4.1, 4.2, 4.3 (M) | Non-RT RIC trains the AI/ML models with the collected data. Trained AI/ML models are deployed and activated in Near-RT RIC through SMO over O1 or O2 Interface.
Non-RT RIC constantly monitors performance and energy consumption of the E2 Node and the O-RU for inference, such as cell load related and traffic information, EE/EC measurement reports, geolocation information etc. | | +| Steps 5.1, 5.2 (M) | SMO may trigger RF Channel Reconfiguration in the Near-RT RIC via O1 interface or optionally Non-RT RIC may provide policies via A1 interface guiding the Near-RT RIC RF Channel Reconfiguration EE/ES function. | | +| Steps 6.1, 6.2, 6.3, 6.4, 6.5, 6.6 (M) | Based on the AI/ML inference in Near-RT RIC, considering optimization policies, the Near-RT RIC may request the E2 Node to prepare and execute RF Channel Reconfiguration.

E2 Node may request O-RU to prepare and execute RF Channel Reconfiguration changes such as,
  • i. O-RU Tx/Rx Array selection
  • ii. Modification of the number of SU/MU MIMO spatial streams or data layers.
  • iii. Modification of the number of SSB beams.
  • iv. Modification of the O-RU Antenna Transmit power.
| | +| Steps 7.1, 7.2 (M) | Based on performance analysis of AI/ML model, Non-RT RIC may update AIML model in Near-RT RIC. | | +| Ends when | E2 Node becomes non-operational or when the operator disables the optimization functions for Energy Saving. | | +| Exceptions | None | | +| Post Conditions | Non-RT RIC continues closed loop monitoring of Energy Saving function for E2 Node and O-RU.
E2 Node and O-RU operate using the newly deployed parameters/models and state. | | + +``` + +@startuml +skin rose +skinparam defaultFontSize 15 +autonumber +Box "Service Management & \n Orchestration Framework" #gold + Participant "Collection & Control" as smo + Participant " Non-RT RIC" as NRTRIC +End box +Box "O-RAN Nodes" #lightpink + Participant "Near-RT RIC" as RTRIC + Participant "E2-Nodes" as E2NODES + Participant "O-RUs" as ORUs +End box +autonumber 1.1 +group Data Collection +alt via O1 +smo -> E2NODES : <> Data collection request for Energy Saving +E2NODES -> ORUs : <> Data collection request +Else via OFH-MP +smo -> ORUs : <> Data collection request +end +autonumber 2.1 +alt Via O1 +ORUs -> E2NODES : <> Measurement Data Collection +E2NODES -> smo : <> Measurement Collection for Energy Saving +Else via OFH-MP +ORUs -> smo : <> Measurement Data Collection +E2NODES -> smo : <> Measurement Collection for Energy Saving +End +autonumber 3 +smo -> NRTRIC : <> Data Retrieval +end +autonumber 4.1 +group AI/ML workflow +NRTRIC -> NRTRIC : AI/ML Model training +NRTRIC -> NRTRIC : Monitoring & Analysis of Energy Efficiency \n & Consumption (E2 +Nodes & O-RU) (s +NRTRIC -> RTRIC : <> or <> Deploy AI/ML model +end +autonumber 5.1 +group Optimization Trigger and Policy +alt via O1 +smo -> RTRIC : <> Optimization Trigger/Target +else via A1 +NRTRIC --> RTRIC : <> Intent based Policy +end +autonumber 6.1 +group Actor Data Collection & Decision Making +RTRIC -> E2NODES : <> Data collection request for Energy Saving +E2NODES -> ORUs : <> Data collection request for Energy Saving +ORUs -> E2NODES : <> Measurement Data Collection for Energy Saving +E2NODES -> RTRIC : <> Measurement Data Collection for Energy Saving +RTRIC -> RTRIC: AI/ML model inference +RTRIC -> E2NODES: <> RF Channel Reconfiguration \nenforcement for Energy saving +E2NODES -> ORUs: <> Updated O-RU Configurations +autonumber 6.1 +group AI/ML workflow +NRTRIC -> NRTRIC : Performance analysis of AI/ML model \n(with possible actions, e.g. +fallback, re-training) +NRTRIC -> RTRIC : <> or <> Update AI/ML model + +end +@enduml + +``` + +![RF Channel Reconfiguration flow diagram: AI/ML inference in Near-RT RIC. The diagram shows a sequence of steps across four main components: Service Management & Orchestration Framework (Collection & Control, Non-RT RIC), Near-RT RIC, E2-Nodes, and O-RUs. The process includes Data Collection (1.1-1.3, 2.1-2.4, 3), AI/ML workflow (4.1-4.3), Actor Data Collection & Decision Making (6.1-6.7), and a final AI/ML workflow (6.1-6.2).](fe7ee60a1d75fc06043aa008f4f81f3a_img.jpg) + +The diagram illustrates the RF Channel Reconfiguration flow, specifically focusing on AI/ML inference in the Near-RT RIC. The process is organized into four main sections across the lifecycle: + +- Data Collection:** + - 1.1 <> Data collection request for Energy Saving:** Initiated by the Service Management & Orchestration Framework (Collection & Control) via O1 to the Near-RT RIC. + - 1.2 <> Data collection request:** Sent from the Near-RT RIC to E2-Nodes. + - 1.3 <> Data collection request:** Sent from the Service Management & Orchestration Framework (via OFH-MP) to the Near-RT RIC. + - 2.1 <> Measurement Data Collection:** Sent from E2-Nodes to the Near-RT RIC. + - 2.2 <> Measurement Collection for Energy Saving:** Sent from the Service Management & Orchestration Framework (via O1) to the Near-RT RIC. + - 2.3 <> Measurement Data Collection:** Sent from the Near-RT RIC to E2-Nodes. + - 2.4 <> Measurement Collection for Energy Saving:** Sent from the Service Management & Orchestration Framework (via O1) to the Near-RT RIC. + - 3 <> Data Retrieval:** Sent from the Service Management & Orchestration Framework (Collection & Control) to the Near-RT RIC. +- AI/ML workflow:** + - 4.1 AI/ML Model training:** Internal to the Service Management & Orchestration Framework (Non-RT RIC). + - 4.2 Monitoring & Analysis of Energy Efficiency & Consumption (E2 Nodes & O-RU)s:** Internal to the Service Management & Orchestration Framework (Non-RT RIC). + - 4.3 <> or <> Deploy AI/ML model:** Sent from the Service Management & Orchestration Framework (Non-RT RIC) to the Near-RT RIC. +- Actor Data Collection & Decision Making:** + - 6.1 <> Data collection request for Energy Saving:** Sent from the Near-RT RIC to E2-Nodes. + - 6.2 <> Data collection request for Energy Saving:** Sent from the Near-RT RIC to O-RUs. + - 6.3 <> Measurement Data Collection for Energy Saving:** Sent from O-RUs to the Near-RT RIC. + - 6.4 <> Measurement Data Collection for Energy Saving:** Sent from E2-Nodes to the Near-RT RIC. + - 6.5 AI/ML model inference:** Internal to the Near-RT RIC. + - 6.6 <> RF Channel Reconfiguration enforcement for Energy saving:** Sent from the Near-RT RIC to E2-Nodes. + - 6.7 <> Updated O-RU Configurations:** Sent from the Near-RT RIC to O-RUs. +- Final AI/ML workflow:** + - 6.1 Performance analysis of AI/ML model (with possible actions, e.g. fallback, re-training):** Internal to the Service Management & Orchestration Framework (Non-RT RIC). + - 6.2 <> or <> Update AI/ML model:** Sent from the Service Management & Orchestration Framework (Non-RT RIC) to the Near-RT RIC. + +RF Channel Reconfiguration flow diagram: AI/ML inference in Near-RT RIC. The diagram shows a sequence of steps across four main components: Service Management & Orchestration Framework (Collection & Control, Non-RT RIC), Near-RT RIC, E2-Nodes, and O-RUs. The process includes Data Collection (1.1-1.3, 2.1-2.4, 3), AI/ML workflow (4.1-4.3), Actor Data Collection & Decision Making (6.1-6.7), and a final AI/ML workflow (6.1-6.2). + +Figure 6.2.2.1-1: RF Channel Reconfiguration flow diagram: AI/ML inference in Near-RT RIC + +#### 6.2.2.2 O-RAN Entity Roles + +##### 1) SMO (including Non-RT RIC) + +- a) Collect necessary cell configurations, performance indicators and measurement reports (e.g., cell load related and traffic information, EE/EC measurement reports, geolocation information) from E2 Node and O-RU, for the purpose of training AI/ML models that assist in the EE/ES functions. +- b) Trigger and perform EE/ES AI/ML model training/retraining. +- c) Analyze the data received from E2 Node and O-RU to trigger optimization for RF Channel Reconfiguration. +- d) Provide optimization trigger, optimization targets, and A1 policies (e.g., change of Tx/Rx Array Selection based on 50 % peak power consumptions) to Near-RT RIC via O1 or A1 interface. + +##### 2) Near-RT RIC + +- a) Collect necessary cell configurations, performance indicators and measurement reports (e.g., cell load related and traffic information, EE/EC measurement reports) from E2 Nodes and O-RU. +- b) Receive EE/ES AI/ML model for deployment via O1 or O2. +- c) Receive EE/ES related configuration management via O1 interface and/or policies via A1 interface for consideration during optimization. +- d) Analyze the data received from E2 Node and perform AI/ML model inference to determine RF Channel Reconfiguration actions for EE/ES (e.g., O-RU Tx/Rx Array Selection, modification of the number of SSB beams, modification of the O-RU Antenna Transmit power, modification of the number of SU/MU MIMO spatial streams or data layers) to be performed considering the optimization targets/policies. +- e) Provide policies and/or required information over E2 interface to trigger actions for EE/ES optimization. + +##### 3) E2 Node + +- a) Report necessary cell configurations, performance indicators and measurement reports (e.g., cell load related and traffic information, EE/EC measurement reports) to SMO via O1 interface and to Near-RT RIC via E2 or O1 Interface. +- b) Perform O-RU Tx/Rx Array Selection, modification of the number of SSB beams, modification of the O-RU Antenna Transmit power, modification of the number of SU/MU MIMO spatial streams or data layers as part of RF Channel Reconfiguration actions for EE/ES optimization. + +##### 4) O-RU + +- a) Report EC and EE related information over Open FH M-Plane interface to O-DU or alternatively to SMO directly. +- b) Perform actions required to perform O-RU RF Channel Reconfiguration as part of EE/ES optimization. +- c) Perform actions such as O-RU Tx/Rx Array Selection, modification of the number of SSB beams, modification of the O-RU Antenna Transmit power, modification of the number of SU/MU MIMO spatial streams or data layers as part of RF Channel Reconfiguration actions for EE/ES optimization. + +#### 6.2.2.3 Input/Output Data Requirements + +##### 6.2.2.3.1 Summary + +###### Input Data + +###### 1) SMO and E2 Node + +- Load statistics per cell and per carrier, such as number of active users, average number of RRC connections, average number of scheduled active users per TTI, PRB utilization, DL/UL Cell/User throughput, PMI/CSI reports. +- Latency statistics per cell (if URLLC slices are involved, latency is used in the EE definition, 3GPP TS 28.554 [7]). + +###### 2) O-RU + +- Power consumption metrics: Mean total/per carrier power consumption, mean total/per carrier transmit power. +- Information of O-RU for supported Tx/Rx Array selection along with power consumption (site/O-RU input power needed for certain EE KPIs). + +###### Output Data + +###### 1) Non-RT RIC to Near RT RIC + +- O1 Configuration (i.e., ES optimization trigger/target) OR +- A1 Policy for ES optimization + +###### 2) Near-RT RIC to E2 Node to O-RU + +- RF Channel Reconfiguration actions which can include, + - O-RU Tx/Rx Array selection + - Modification of the number of SU/MU MIMO spatial streams or data layers + - Modification of the number of SSB beams + - Modification of the O-RU Antenna Transmit power + +##### 6.2.2.3.2 Detailed Input Requirements + +Initialization: + +**Table 6.2.2.3-1: Initialization** + +| Input Data | | | | | | +|------------------------|-------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------|---------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing / New Definitions | +| O1 | SMO / Near-RT RIC | EE Optimization target for RF Channel Re-configuration | | manual or event triggered | New | +| | | E.g., (average or max) NG-RAN data Energy Efficiency | bit/J | | 3GPP TS 28.554 [7] (Cl. 6.7.1) | +| O1 | SMO / Near-RT RIC | Maximum Initial Access Latency for given SSB Beam Configuration | ms | Initialization | New: KPI metric input by the operator | +| E2, O1, R1 | E2 Node (O-DU) / Near-RT RIC / SMO / rApp | Carrier/cell characteristics | - | manual or event triggered (e.g., SMO feature activation, E2 Node startup/failure/reconfig.) | New | +| | | E.g., physical location, transmit direction, carrier frequency, coverage parameters, configured transmit power, beam width, coverage shape, tilt, azimuth, carrier-cell mapping, carrier-HW mapping | - | | 3GPP TS 28.541 [11] (Cl. 4.3.6, 4.3.38, 4.3.39, 4.3.40, 4.3.74) | +| O-FH (M-Plane) | O-RU / O-DU | Supported common beam configuration from O-RU per cell | file | Initialization | O-RAN.WG5.MP (Chapter 8) | +| E2 | O-DU / Near-RT RIC | Supported SSB and CSI-RS TRS configurations per cell | - | Initialization | 3GPP TS 38.331 [16] (Sec. 6.3.2) | +| O-FH (M-Plane), O1, R1 | O-RU / O-DU / SMO / rApp | O-RU reports all offered Tx/Rx Arrays | file | Initialization | New Definition required in O-RAN.WG5.MP

o-ran-uplane-conf.yang module

o-ran-beamforming.yang module | +| O-FH (M-Plane) | O-RU / O-DU | O-RU reports all offered Tx/Rx Arrays | values in IE | Initialization | New Definition required in O-RAN.WG4.MP

o-ran-uplane-conf.yang module

o-ran-beamforming.yang module | + +###### AI/ML Model Training: + +Table 6.2.2.3-2: AI/ML Model Training + +| Input Data | | | | | | +|------------------------------------------|-----------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|------------------------------|--------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing/New Definitions | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | DL PDCP SDU Data Volume per interface (Data Volume in DL delivered from O-CU-UP to O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | (non-real time for training) | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.3.6.2.3) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | UL PDCP SDU Data Volume per interface (Data Volume in UL delivered to O-CU-UP from O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | (non-real time for training) | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.3.6.2.4) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Number of active UEs in NG-RAN (Number of RRC_CONNECTED UEs) per cell | Integer | (non-real time for training) | Measurement: 3GPP TS 28.552 [12] (Sec. 5.1.1.23, A.7, A.60) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | RSRQ measurement per SSB per cell | dB | (non-real time for training) | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.1.31) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | RSRP measurement per SSB per cell | dBm | (non-real time for training) | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.1.22) | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | SINR measurement per SSB per cell | dB | > min | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.1.32) | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | Energy consumption | kWh | (non-real time for training) | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.1.19.3) | +| O-FH (M-Plane) or O-FH (M-Plane), O1, R1 | O-RU / O-DU or O-RU / O-DU / SMO / rApp | Power consumed by O-RU or its hardware components | W | (non-real time for training) | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.1.19.2)

Reporting: O-RAN.WG4.MP (Sec. B.1, B.5) | +| O1, R1 | E2 Node (O-DU) / SMO / rApp | Over the air Transmit power by O-RU
Note: This measurement is required to calculate energy efficiency of O-RU. | W | (non-real time for training) | New Measurement and New Reporting required in O-RAN.WG5.MP | +| O1, R1 | E2 Node (O-CU) / SMO / rApp | Number of active UEs in NG-RAN (Number of RRC_CONNECTED UEs) per cell | Integer | (non-real time for training) | Measurement: 3GPP TS 28.552 [12] (Sec. 5.1.1.23, A.7, A.60) | + +Input Decision Making / AI/ML Inference: + +**Table 6.2.2.3-3: Input Decision Making / AI/ML Inference** + +| Input Data | | | | | | +|--------------------------------------|------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|------------------------------|--------------------------------------------------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing / New Definitions | +| E2 | E2 Node (O-CU) / Near-RT RIC | DL PDCP SDU Data Volume per interface (Data Volume in DL delivered from O-CU-UP to O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | per N x 100ms | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.3.6.2.3) | +| E2 | E2 Node (O-CU) / Near-RT RIC | UL PDCP SDU Data Volume per interface (Data Volume in UL delivered to O-CU-UP from O-DU, per PLMN, per QoS level, per slice, per Interface (F1-U, Xn-U, X2-U)) | Mbit | per N x 100ms | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.3.6.2.4) | +| E2 | E2 Node (O-CU) / Near-RT RIC | Number of active UEs in NG-RAN (Number of RRC_CONNECTED UEs) per cell | Integer | per N x 100ms | Measurement: 3GPP TS 28.552 [12] (Sec. 5.1.1.23, A.7, A.60) | +| E2 | E2 Node (O-DU) / Near-RT RIC | PRACH correlation power for every received PRACH corresponding to each active SSB Beam Index | dBm | per N x 100ms | New Measurement and New Reporting: The measurement at O-DU may be delivered | +| E2 | E2 Node (O-CU) / Near-RT RIC | RSRQ measurement per SSB per cell | dB | per N x 100ms | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.1.31) | +| E2 | E2 Node (O-CU) / Near-RT RIC | RSRP measurement per SSB per cell | dBm | per N x 100ms | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.1.22) | +| E2 | E2 Node (O-CU) / Near-RT RIC | SINR measurement per SSB per cell | dB | per N x 100ms | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.1.32) | +| E2 | E2 Node (O-CU) / Near-RT RIC | Energy consumption | kWh | (non-real time for training) | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.1.19.3) | +| O-FH (M-Plane) or O-FH (M-Plane), E2 | O-RU / O-DU or O-RU / O-DU / Near-RT RIC | Power consumed by O-RU or its hardware components | W | (non-real time for training) | Measurement: 3GPP TS 28.552 [12] (Cl. 5.1.1.19.2)

Reporting: O-RAN.WG4.MP (Sec. B.1, B.5) | +| E2 | E2 Node (O-DU) / Near-RT RIC | Over the air Transmit power by O-RU
Note: This measurement is required to calculate energy efficiency of O-RU. | W | (non-real time for training) | New Measurement and New Reporting required in O-RAN.WG5.MP | + +##### 6.2.2.3.3 Detailed Output Requirements + +Output Decision Making / AI/ML Inference: + +**Table 6.2.2.3-4: Output Decision Making / AI/ML Inference** + +| Output Data | | | | | | +|----------------|------------------------------|----------------------------------------------------------------------------------------------------|-------|------------------|---------------------------------------------------------| +| Interface | Source / Target | Name/Description | Units | Reporting Period | Existing / New Definitions | +| O-FH (M-Plane) | O-DU / O-RU | Candidate O-RU's appropriate Array selection | - | > min | O-RAN.WG4.MP
o-ran-uplane-conf.yang | +| | | Maximum number of Max SU/MU MIMO spatial streams or data layers | - | > min | New Definition required in O-RAN.WG4.MP | +| | | Recommended O-RU Antenna Transmit power | - | > min | O-RAN.WG4.MP
urn:o-ran:uplane-conf
Module gain | +| E2 | Near-RT RIC / O-DU | Candidate O-RU's appropriate Array selection | - | > min | New Definition required in WG2 R1 and O-RAN.WG5.O-DU-O1 | +| | | Maximum number of Max SU/MU MIMO spatial streams or data layers | - | > min | New Definition required in O-RAN.WG4.MP | +| | | Inferred O-RU SS Burst Set (SS Block Number and SS Burst Periodicity) and CSI-RS TRS Configuration | - | Initialization | 3GPP TS 38.331 [16]
IE:
ServingCellConfigCommon | +| | | Recommended O-RU Antenna Transmit power | - | > min | O-RAN.WG4.MP
urn:o-ran:uplane-conf
Module gain | +| E2 | E2 Node (O-DU) / Near-RT RIC | Confirmation (Success/Failure) | - | event triggered | New | + +## 6.3 Impact Analysis on O-RAN Work Groups + +This is an initial impact analysis as part of the WG1 UCTG Network Energy Saving work on RF Channel Reconfiguration use case. The intention is to estimate the expected standardization effort within the O-RAN work groups. It is up to the WGs to decide how RF Channel Reconfiguration functionality should be specified in specifications of each WG. + +| # | WGs/FGs | Spec. No | Objective description | +|---|--------------------------|--------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | WG1 (Use case) | O-RAN.WG1.NES-USE-CASES-TR
O-RAN.WG1.Use-Cases-Detailed-Specification | Update WG1 NES use case analysis report and use-case detailed specification with RF Channel Reconfiguration use case. No impact to existing architecture | +| 2 | WG2 (Non-RT RIC, A1, R1) | O-RAN.WG2.R1GAP
O-RAN.WG2.R1UCR
O-RAN.WG2.R1TD (TBD) | Updates to R1 services and procedures for RF Channel Reconfiguration use case | +| | | O-RAN.WG2.Non-RT-RIC-ARCH | Reviewing procedures to implement RF Channel Reconfiguration use cases and generate corresponding A1 policies/updates of O1 and O2-related services via R1 interface, if any. | +| | | O-RAN.WG2.Use-Case-Requirements | Specifying RF Channel Reconfiguration use case and its requirements in WG2 UCR specification | +| | | O-RAN.WG2.A1GAP
O-RAN.WG2.A1TD | Reviewing requirement for policy driven implementation 2nd deployment option of RF Channel Reconfiguration use case captured in document. | +| 3 | WG3 (Near-RT RIC, E2) | O-RAN.WG3.UCR | Specifying RF Channel Reconfiguration use case and its requirements in WG3 UCR specification | +| | | O-RAN.WG3.RICARCH | No impact identified | +| | | O-RAN.WG3.E2GAP | No impact identified | +| | | O-RAN.WG3.E2AP | No impact identified | +| | | O-RAN.WG3.E2SM-RC or NEW: O-RAN.WG3.E2SM-CC | Identify and specify RAN E2 actions necessary for RF Channel Reconfiguration use case specially modifying mMIMO layer, Power, Tx/Rx Array selections, number of SSB Beams through E2 Node towards O-RU. | +| | | O-RAN.WG3.E2SM-KPM | Identify and specify RAN E2 measurement required analysis of ES and EC for RF Channel Reconfiguration optimization through Near-RT RIC | +| 4 | WG4 (O-FH) Impact | O-RAN.WG4.MP | Identify the relevant impacts on M-Plane for both Hierarchical and hybrid model to accommodate management features requirements towards O-RU. Define O-RU Energy efficiency KPIs and counters. | +| | | O-RAN-WG4.CUS | Identify the relevant impacts on CUS-Plane and data model to support various Tx/Rx Array selections. | +| 5 | WG5 (O1) Impact | O-RAN.WG5.O-DU-O1
O-RAN.WG5.O-CU-O1
O-RAN.WG5.MP | Identify specific O-DU operational and data model aspects of the feature content including the interface between SMO and -O-DU, and the one between SMO and O-CU. Make appropriate changes to the O-DU data model and other WG5 specifications as needed. | +| 6 | WG7 | - | WG7 needs to provide reference architecture of O-RU which supports Tx/Rx Array selection. Study energy savings gains from Tx/Rx array selection including limiting maximum number of layers. | +| 7 | WG10 | O-RAN.WG10.O1-Interface
O-RAN.WG10.OAM-Architecture
O-RAN.WG10.Information Model and Data Models | Identify the relevant impacts on O1 interface to support RF Channel Reconfiguration use case and IM/DM to capture requirements for use cases. | + +## 6.4 Relation and Impact on 3GPP Specifications + +3GPP RAN does a Rel.18 study on network energy savings for NR (i.e. FS\_Netw\_Energy\_NR, see Sec. 5.4.2 for details). Within this study 3GPP RAN WGs consider related techniques such as RU Tx/Rx array selection, modification of number of SSB beams, adaptation of RU transmit power etc. + +## 6.5 Gain Analysis + +The potential of energy savings from RF Channel Reconfiguration is dependent upon several factors such as network deployment, traffic pattern/load, user distribution, antenna type and specific O-RU architecture etc. Computational analysis results for two example scenarios, one for 4T4R O-RU and one for 64T64R O-RU, are provided below. The calculations are based on the load profile and the power consumption categorization of O-RU functional blocks as outlined in Annex B. + +Energy savings gain from RF Channel Reconfiguration would be equivalent to power consumption of the O-RU hardware components that can be shut down or put into energy savings mode when the number of active antennas is reduced. As illustrated in Figure 6.5-1, energy savings gain would mostly be derived from partial shutdown of the RF Processing Unit and Digital Processing Unit (depending on the antenna configuration), while other functional modules such as O-RAN Fronthaul Processing Unit, Power Supply Unit and some other components would still be fully or partially functioning, and the power consumptions would be more or less consistent irrespective of the number of active antennas. + +![Figure 6.5-1: Energy savings for RF Channels. This block diagram illustrates the power states of various O-RU functional blocks. A legend at the top shows three states: 'Fully active power state' (red), 'Lowest power state' (green), and 'Lower power state' (yellow). The diagram shows the following blocks and their states: 1. ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer: Fully active (red). 2. eCPRI (De-) Compression, Optical, Security: Fully active (red). 3. Timing: Fully active (red). 4. Digital Processing Unit (N x Tx/Rx): Fully active (red). 5. DFE (N x Tx/Rx): Fully active (red). 6. AFE (N x Tx/Rx): Fully active (red). 7. ADC, DAC: Fully active (red). 8. RF Processing unit (N x Tx/Rx): Fully active (red). 9. Tx/Rx Reciprocity CAL Option #1, #2: Fully active (red). 10. Filter N: Fully active (red). 11. Antenna N ports: Fully active (red). 12. POWER SUPPLY: Fully active (red). 13. Tx/Rx Reciprocity CAL Option #3: Fully active (red). 14. Optional Integration: Not shown. The diagram also indicates interfaces: Optical interface to/from O-DU, Rx, and Tx; Digital interface; and RF interface.](109a381f93f2dee7722856f6e802ff1b_img.jpg) + +Figure 6.5-1: Energy savings for RF Channels. This block diagram illustrates the power states of various O-RU functional blocks. A legend at the top shows three states: 'Fully active power state' (red), 'Lowest power state' (green), and 'Lower power state' (yellow). The diagram shows the following blocks and their states: 1. ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer: Fully active (red). 2. eCPRI (De-) Compression, Optical, Security: Fully active (red). 3. Timing: Fully active (red). 4. Digital Processing Unit (N x Tx/Rx): Fully active (red). 5. DFE (N x Tx/Rx): Fully active (red). 6. AFE (N x Tx/Rx): Fully active (red). 7. ADC, DAC: Fully active (red). 8. RF Processing unit (N x Tx/Rx): Fully active (red). 9. Tx/Rx Reciprocity CAL Option #1, #2: Fully active (red). 10. Filter N: Fully active (red). 11. Antenna N ports: Fully active (red). 12. POWER SUPPLY: Fully active (red). 13. Tx/Rx Reciprocity CAL Option #3: Fully active (red). 14. Optional Integration: Not shown. The diagram also indicates interfaces: Optical interface to/from O-DU, Rx, and Tx; Digital interface; and RF interface. + +**Figure 6.5-1: Energy savings for RF Channels** + +### 6.5.1 RF Channel Reconfiguration ES Gain Analysis for 4T4R O-RU + +When the traffic load is low, a 4T4R O-RU might be scaled down to 2T2R such that some part of the RF components in the O-RU might be switched off to save energy. When scaling down from 4T4R to 2T2R, RF Processing Unit for the two RF channels to be switched off might be shut down as illustrated in Figure 6.5.1-1. + +![Figure 6.5.1-1: O-RU power saving for RF Channel Reconfiguration. The figure consists of two bar charts. The left chart, titled 'Transmitted Power (4T4R operation)', shows four bars representing power consumption across different TX paths. The right chart, titled 'Transmitted Power (2T2R operation)', shows two bars, indicating a reduction in the number of active TX paths. Both charts have a vertical axis labeled 'W' (Watts) and a horizontal axis representing different TX paths.](48e766a24d37cb68c327dfc465f58b73_img.jpg) + +Figure 6.5.1-1: O-RU power saving for RF Channel Reconfiguration. The figure consists of two bar charts. The left chart, titled 'Transmitted Power (4T4R operation)', shows four bars representing power consumption across different TX paths. The right chart, titled 'Transmitted Power (2T2R operation)', shows two bars, indicating a reduction in the number of active TX paths. Both charts have a vertical axis labeled 'W' (Watts) and a horizontal axis representing different TX paths. + +**Figure 6.5.1-1: O-RU power saving for RF Channel Reconfiguration** + +The energy saving gain from reducing the number of RF channels from 4T4R to 2T2R is analyzed based on the system parameters in Table 6.5.1-1 and the example O-RU power profile considering power consumption from operational experience provided in Table 6.5.1-2. + +**Table 6.5.1-1: O-RU Configuration for ES gain analysis** + +| | | +|----------------------------|---------| +| No. of antennas | 4T4R | +| No. of layers | 4 | +| Bandwidth | 100 MHz | +| Carrier frequency | 3.5 GHz | +| Tx power per array element | 30 W | +| Technology | 5G NR | + +**Table 6.5.1-2: Example power profile for 4T4R O-RU** + +| Operating Load (Traffic) | Configuration | Total O-RU (W) | ORAN Fronthaul Processing Unit (W) | Digital Processing Unit (W) | RF Processing Unit (W) | Power Unit & other components (W) | +|----------------------------|-----------------------------------------------|----------------|------------------------------------|-----------------------------|------------------------|-----------------------------------| +| Busy hour Load | 4T4R | 550 | 10 | 25 | 495 | 20 | +| Low load | 4T4R | 200 | 10 | 25 | 145 | 20 | +| Low load | 2T2R
RF Channel Reconfiguration
ES Mode | 120 | 8 | 20 | 75 | 17 | +| Maximum energy saving gain | 2T2R vs. 4T4R (low load) | 80 | 2 | 5 | 70 | 3 | + +Compared to the low load scenario, a maximum energy savings of up to 80 W per O-RU can be achieved. Achievable energy savings might be lower and might vary in practice. Besides an impact on receive signal quality and spectral efficiency, also coverage and beam characteristics will be affected. A lower spectral efficiency may for instance increase overall transmission time of the active UEs when transmitting a packet. + +An example calculation for yearly energy saving potential considering a shutdown of 10000 O-RUs during 3 hours per day is provided in Table 6.5.1-3. + +**Table 6.5.1-3: Power saving calculation example for 4T4R O-RU** + +| Factor | Value | +|----------------------------------------------------------------|-------| +| RU power savings during RF channel switch off (low load) [W] | 80 | +| Number of hours of switch off per day (50% of low load period) | 3 | +| Number of O-RUs | 10000 | +| Yearly energy saving [MWh] | 876 | + +### 6.5.2 RF Channel Reconfiguration ES Gain Analysis for 64T64R O-RU + +The energy saving gain from RF Channel Reconfiguration of a 64T64R O-RU to 32T32R is analyzed based on the system parameters in Table 6.5.2-1 and the example O-RU power profile considering power consumption from operational experience provided in Table 6.5.2-2. + +**Table 6.5.2-1: O-RU Configuration for ES gain analysis** + +| | Normal Mode | RF Channel Reconfiguration ES | +|-----------------------------------|-------------|-------------------------------| +| Configuration | 64T64R | 32T32R | +| No. of layers | 16 | 8 | +| Bandwidth | 100 MHz | 100 MHz | +| Carrier frequency | 3.5 GHz | 3.5 GHz | +| Tx power per array element | 3 W | 3 W | + +**Table 6.5.2-2: Example power profile for 64T64R O-RU** + +| Operating Load (Traffic) | O-RU RF Channel Configuration | Total O-RU Power Consumption (W) | ORAN Fronthaul Processing Unit (W) | Digital Processing Unit (W) | RF Processing Unit (W) | Power Supply & other components (W) | +|----------------------------|----------------------------------------------|----------------------------------|------------------------------------|-----------------------------|------------------------|-------------------------------------| +| Busy hour load | 64T64R | 1120 | 50 | 200 | 800 | 70 | +| Low load | 64T64R | 520 | 50 | 200 | 200 | 70 | +| Low load | 32T32R
RF Channel Reconfiguration ES Mode | 290 | 35 | 100 | 100 | 55 | +| Maximum energy saving gain | 64T64R vs. 32T32R (low load) | 230 | 15 | 100 | 100 | 15 | + +Compared to the low load scenario, a maximum energy saving gain of up to 230 W per O-RU can be achieved. As stated before, the achievable energy savings might be lower and might vary in practice. + +An example calculation for yearly energy saving potential considering a shutdown of 10000 O-RUs during 3 hours per day is provided in Table 6.5.2-3. + +**Table 6.5.2-3: Power saving calculation example for 64T64R O-RU** + +| Factor | Value | +|----------------------------------------------------------------|-------| +| RU power savings during RF channel switch off (low load) [W] | 230 | +| Number of hours of switch off per day (50% of low load period) | 3 | +| Number of O-RUs | 10000 | +| Yearly energy saving [MWh] | 2519 | + +## 6.6 Feasibility Analysis + +### 6.6.1 Continuous operation during RF Channel Reconfiguration + +Changing configuration of O-RU such as shutting down 32 TRX of the 64TRX for the purpose of energy savings may impact the existing users if it requires full or partial reset of O-RU, hence care should be exercised on how the reconfiguration of antenna array is performed. + +### 6.6.2 Impact on Coverage + +The coverage during TRX switch should be maintained as much as possible. A reduction of transceiver chains may impact the number of transmitted SSB beams, the beam shapes, as well as the overall transmit power, affecting the various downlink physical channels. A limited coverage might result in reduced user throughput, radio link failures, beam failures, and call drops. + +### 6.6.3 Impact and Relation to UE specific Base Station Algorithms + +A TRX switch might impact the cell coverage and the beam characteristics. This sudden change in radio channel characteristics might affect UE specific base station algorithms (e.g., inner and outer loop link adaptation, power control, beam selection, adaptive MIMO, channel quality reporting etc.) and may result in a transitory phase until transmission can be continued or is stabilized. + +It is up to the proprietary scheduler algorithm to handle such events most efficiently. Scheduling (e.g. user selection, resource allocation), adaptive MIMO (e.g. MIMO mode, spatial streams and layers) and link adaptation (e.g. Coding/Modulation Scheme, transmit power) will be adjusted instantaneously every scheduling instance and transmission time interval by the base station without time constrained external control. + +### 6.6.4 Limited O-RU / O-DU Capabilities + +The capabilities of the O-RU in terms of configurable antenna arrays, transition times, as well as the capabilities of the O-DU scheduling respective antenna arrays with the various MIMO transmission modes may be limited. Hence, respective capabilities are required to be known. The capabilities between the different array configurations may differ significantly in terms of supported SU/MU MIMO modes as well as in terms of supported MIMO layers, streams etc. + +# 7 Advanced Sleep Mode Selection + +## 7.1 Problem Statement, Solution and Value Proposition + +This Use Case describes a method to achieve intelligent energy saving by optimizing the sleep mode via RIC-based guidance. + +### **Background** + +O-RU and E2 Nodes (O-CU, O-DU) may implement various Sleep Modes (SMs). The SMs are enabled by Non-RT RIC/SMO and/or Near-RT RIC. When enabled, the E2 Nodes select among the SMs considering their capabilities, the actual traffic situation, and the network conditions. Different SM operate at different time scales (e.g., symbol, slot, frame). + +### **Problem Statement** + +In a single vendor network where components are not disaggregated, the O-RU's capabilities are well-known within the E2 Node, allowing for autonomous execution of sleep modes. However, implementing sleep modes in O-RAN requires the O-DU and O-CU to understand the sleep mode capabilities of the O-RU, including the number and depth of sleep modes. Also, Near/Non-Real-Time RIC need to be aware of the O-DU and O-CU capabilities to drive policies related to sleep modes. For optimization, O-RU and O-DU need to report energy efficiency related measurements and KPIs from which the power saving can be observed. To achieve this, effective communication and coordination between all components is necessary. + +### **Solution** + +In this solution the O-RU will expose its SM capabilities to the O-DU in the initial configuration phase. Next, the O-DU will expose a set of commonly supported SMs to the SMO (over O1) and Non-RT RIC (via SMO and R1) and/or the Near-RT RIC (over E2) which is available for utilization during operation. Information exposed towards the Non-RT and/or Near-RT RIC will include a unique identifier of each SM, and additional operational parameters, e.g., minimum duration of activation, transition times between SMs, whether to be applied on UL/DL, etc. + +Moreover, the Non-RT RIC and/or Near-RT RIC will collect for the different SMs data related to network load and performance, cell configuration, and energy/power consumption. + +Based on the above two sets of information the Non-RT RIC and/or Near-RT RIC train an ML model, which will infer optimized SM utilization range (i.e., a set of SMs the O-DU may dynamically select from at a given or pre-defined time), which is then transmitted to the O-DU as a guidance. Based on the optimized (allowed) SM utilization range, O-DU will select specific SMs. + +Depending on the SMs, O-RU and O-DU may apply such SM selection internally or O-RU may apply a SM based on O-DU request. For instance, O-RU may (or may not) apply a micro sleep internally, while O-DU may (or may not) internally adjust its scheduling strategy to maximize possible O-RU micro sleep periods considering O RU SM capabilities. Energy saving is thus obtained during regular operation when O-DU schedules data in a more optimized way. O-DU may for example prioritize time-domain scheduling over frequency domain scheduling or may compress data transmission to increase the number of symbols or slots without data. O-DU cannot enforce the O-RU to apply its micro sleep due to the fast internal operation and Near-RT RIC may not be able to enforce O-DU to adjust its internal scheduling strategy. The energy saving gains can be observed by monitoring respective Energy Efficiency KPIs. + +In the alternative on request operation, O-DU may for instance configure the O-RU to switch off a certain part of the O-RU to support a deep sleep operation considering the timing constraints as communicated + +during the capability exchange. Energy saving is thus obtained when O-RU applies a new configuration as requested by O-DU. + +### **Value Proposition** + +Firstly, the Non-RT RIC and/or Near-RT RIC based AI/ML algorithm may extend the time period or increase the granularity during which the E2 Nodes are allowed to select from their implemented SMs. + +Secondly, this solution allows for an optimized SMs selection in a multi-vendor O-RU/O-DU deployment, by the O-RU/O-DU exposing the required information as part of their SM capabilities. + +## 7.2 Architecture/Deployment Options + +### 7.2.1 Option 1: Training and Inference in Non-RT RIC + +In this deployment option, the Non-RT RIC retrieves the E2 Node SM capabilities over O1 and R1 via SMO, collects the necessary data from the E2 Nodes and trains an ML model, which is then deployed in the rApp. Inference of the optimized SM utilization range is provided as guidance by the rApp. Additionally, external parties (such as prediction rApps or external application servers) may provide additional information for optimization. + +#### 7.2.1.1 Description and UML Diagram + +**Table 7.2.1.1-1: Advanced Sleep Mode Selection: Training and Inference in Non-RT RIC** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Provide optimized SM utilization range as guidance to the O-DU and allow for optimized SM selection in O-DU / O-RU. | | +| Actors and Roles |
  • - SMO/Non-RT RIC: Retrieval of E2 Node SM capabilities.
  • - SMO/Non-RT RIC: Data collection for ML model training and ML model deployment.
  • - Non-RT RIC: Network data collection and analysis, and inference of SM utilization range guidance provided to O-DU.
  • - O-DU: Expose common O-DU/O-RU SM capabilities over O1.
  • - O-RU: Expose SM related capabilities to O-DU.
  • - (Optional) Additional parties: Providing additional data for optimization.
| | +| Assumptions |
  • - O-RU and O-DU expose the necessary information about their available SMs capabilities.
| | +| Pre- conditions |
  • - All relevant functions and components are instantiated and available.
| | +| Begins when | The operator has enabled or has set targets for SM utilization guidance rApp. | | +| Step 1.1, 1.2 (M) | O-RU transmits to O-DU its SM capabilities. O-DU decides on a common set of O-DU/O-RU SM capabilities to utilize during operation. | | +| Step 1.3 (M) | O-DU transmits information about the available O-DU/O-RU SM capabilities to Non-RT RIC/SMO, including minimal operational information. | | +| Step 2.1, 2.2 (M), 2.3 (O) | Data collection request from SMO to E2 Nodes (M) and external entities (O) for training and inference. | | +| Step 2.4, 2.5 (M), 2.6 (O) | Data collection from E2 Nodes (M) and external entities (O) for training in SMO/Non-RT RIC. | | +| Step 2.7 (M) | Non-RT RIC retrieves data for training and inference. | | +| Step 3.1, 3.2, 3.3 (M) | Based on continuous/periodically collected data, Non-RT RIC trains the AI/ML model and deploys it. Non-RT RIC performs inference using the AI/ML model. | | +| Step 4.1 (M) | Non-RT RIC provides SM utilization guidance via SMO and O1 to O-DU. | | +| Step 4.2, 4.3 (O), | O-DU considers Non-RT RIC's SM utilization guidance in its updated scheduling strategy and O-RU applies SM selection internally. | | +| Step 4.4, 4.5, 4.6 (O) | Based on Non-RT RIC's SM utilization guidance, O-DU alternatively selects a SM, O-DU requests a new SM configuration by O-RU over O-FH and O-RU applies the new SM configuration. | | +| Ends when | Operator disables or changes targets for SM utilization guidance rApp. | | +| Exceptions | None identified. | | +| Post-conditions | Non-RT RIC continues to monitor the energy consumption and efficiency and the RAN performance by collecting and monitoring the relevant data over O1. | | + +``` + +@startuml +skinparam defaultFontSize 12 +autonumber + +Box "SMO" #gold + Participant "Collection & Control" as COLL + Participant "Non-RT RIC" as NON +End box + +Box "O-RAN" #lightpink + Participant "O-CU" as OCU + Participant "O-DU" as ODU +End box + +Box "O-RU" #turquoise + Participant "O-RU" as ORU +End box + +Box "EXT" #lightcyan + Participant "EXT" as EXT +End box + +== Initialization == +autonumber 1.1 + ORU -> ODU : <> SM capabilities + ODU -> ODU : SM capability decision + ODU -> COLL : <> SM capability information exposure + ODU -> NON : <> SM capability information exposure + +== Data Collection == +autonumber 2.1 + +Group Data for training and for inference +Loop + COLL -> OCU : <> Data collection request + COLL -> ODU : <> Data collection request + COLL -> EXT : Data collection request + OCU -> COLL : <> Data retrieval + ODU -> COLL : <> Data retrieval + EXT -> COLL : Data retrieval + COLL -> NON : Data retrieval +End loop +End group + +== AI/ML Flow == +autonumber 3.1 + NON -> NON : AI/ML model training + NON -> NON : AI/ML model deployment +Loop + NON -> NON : AI/ML model inference +End Loop + +== SM Guidance (Loop) == +autonumber 4.1 + NON -> COLL: Guidance to utilize SM + COLL -> ODU: <> Guidance to utilize SM + +group Configuration Update + group alt1 + ODU -> ODU: Updated scheduling strategy + ORU -> ORU: Internal SM selection + end + group alt2 + ODU -> ODU: SM selection + ODU -> ORU: <> Request new \nSM configuration + ORU -> ORU: Apply new SM configuration + end +end +end + +``` + +@endum1 + +![Sequence diagram for SM Selection, ML model training in the Non-RT RIC. The diagram shows interactions between SMO (Collection & Control, Non-RT RIC), O-RAN (O-CU, O-DU), O-RU (O-RU), and EXT (EXT). The process includes Initialization, Data Collection, AI/ML Flow, and SM Guidance (Loop).](4092c8460753403c32d0fe1bf17500e0_img.jpg) + +``` + +sequenceDiagram + participant SMO as SMO +Collection & Control +Non-RT RIC + participant O_RAN as O-RAN +O-CU +O-DU + participant O_RU as O-RU +O-RU + participant EXT as EXT +EXT + + Note over O_RAN: Initialization + O_RAN->>O_RU: 1.1 <> SM capabilities + O_RU-->>O_RAN: 1.2 SM capability decision + O_RAN->>SMO: 1.3 <> SM capability information exposure + O_RAN->>SMO: 1.4 <> SM capability information exposure + + Note over O_RAN: Data Collection + Note over SMO: Data for training and for inference + loop + SMO->>O_RAN: 2.1 <> Data collection request + O_RAN->>O_RU: 2.2 <> Data collection request + O_RU->>EXT: 2.3 Data collection request + EXT-->>O_RAN: 2.4 <> Data retrieval + O_RAN-->>SMO: 2.5 <> Data retrieval + O_RAN-->>SMO: 2.6 Data retrieval + O_RAN-->>SMO: 2.7 Data retrieval + end + + Note over O_RAN: AI/ML Flow + O_RAN->>SMO: 3.1 AI/ML model training + O_RAN->>SMO: 3.2 AI/ML model deployment + loop + SMO->>O_RAN: 3.3 AI/ML model inference + end + + Note over O_RAN: SM Guidance (Loop) + O_RAN->>SMO: 4.1 Guidance to utilize SM + O_RAN->>O_RU: 4.2 <> Guidance to utilize SM + + Note over O_RU: Configuration Update + alt1 + O_RU->>O_RAN: 4.3 Updated scheduling strategy + O_RAN->>O_RU: 4.4 Internal SM selection + alt2 + O_RU->>O_RAN: 4.5 SM selection + O_RU->>O_RU: 4.6 <> Request new SM configuration + O_RU->>O_RU: 4.7 Apply new SM configuration + end + +``` + +Sequence diagram for SM Selection, ML model training in the Non-RT RIC. The diagram shows interactions between SMO (Collection & Control, Non-RT RIC), O-RAN (O-CU, O-DU), O-RU (O-RU), and EXT (EXT). The process includes Initialization, Data Collection, AI/ML Flow, and SM Guidance (Loop). + +Figure 7.2.1.1-1: Flow diagram for SM Selection, ML model training in the Non-RT RIC + +#### 7.2.1.2 O-RAN Entity Roles + +##### 1) SMO (including Non-RT RIC) + +- a) Receive common SM capability information and additional operational parameters from O-DU. +- b) Subscribe to and retrieve necessary performance indicators (incl. Energy Efficiency KPIs), measurement reports, UE context information, RAN configurations, and SM usage data from E2 Nodes via the O1 interface for the purpose of AI/ML model training, inference, and performance monitoring. +- c) Optionally, i) collect enrichment information from Application servers and associate enrichment information with collected measurements and configurations, ii) collect prediction or optimization related information from other rApps. +- d) Perform AI/ML model training and deployment. +- e) Send SM utilization guidance for Sleep Mode optimization to E2 Nodes over O1. + +##### 2) E2 Nodes (O-DU in disaggregated architecture) + +- a) Support retrieving the O-RU SM capabilities and additional operational parameters from O-RU via O-FH. +- b) Support reporting the common O-DU/O-RU SM capabilities and additional operational parameters to SMO over O1. +- c) Support reporting of necessary performance indicators (incl. Energy Efficiency KPIs), measurement reports, UE context information, RAN configurations, and SM usage data with required granularity to SMO via the O1 interface. +- d) Receive SM utilization guidance from the SMO via the O1 interface. +- e) Adjust scheduling strategy (to allow O-RU to internally update its used SMs configuration) or alternatively perform SM selection based on SM utilization guidance received from the SMO. +- f) Optionally, request O-RU over O-FH to update its used SM configuration (e.g., switch off a certain O-RU functionality). + +##### 3) O-RU + +- a) Support reporting the O-RU SMs capabilities and additional operational parameters to O-DU via O-FH. +- b) Internally apply SM selection or alternatively receive over O-FH and apply O-DUs request for updated SM configuration. + +#### 7.2.1.3 Void + +### 7.2.2 Option 2: Training in Non-RT RIC and Inference in Near-RT RIC + +In this deployment option, the Non-RT RIC retrieves the E2 Node SM capabilities over O1 and R1 via SMO, collects the necessary data from the E2 Nodes and trains an ML model, which is then deployed in the rApp. Inference of the optimized SM utilization range is provided as guidance by the rApp. Additionally, external parties (such as prediction rApps or external application servers) may provide additional information for optimization. + +#### 7.2.2.1 Description and UML Diagram + +**Table 7.2.2.1-1: Advanced Sleep Mode Selection: Training in Non-RT RIC and Inference in Near-RT RIC** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Provide optimized SM utilization range as guidance to the O-DU and allow for optimized SM selection in O-DU/O-RU. | | +| Actors and Roles |
  • - SMO/Non-RT RIC: Retrieval of E2 Node SM capabilities.
  • - SMO/Non-RT RIC: Data collection for ML model training and ML model deployment.
  • - Near-RT RIC (xApp): Network data collection and analysis, and inference of SM utilization range guidance provided to O-DU.
  • - O-DU: Expose common O-DU/O-RU SM capabilities over O1/E2.
  • - O-RU: Expose SM related capabilities to O-DU.
  • - (Optional) Additional parties: Providing additional data for optimization.
| | +| Assumptions | - O-RU and O-DU expose the necessary information about their available SMs capabilities. | | +| Pre- conditions | - All relevant functions and components are instantiated and available. | | +| Begins when | The operator has enabled or has set targets for SM utilization guidance xApp. | | +| Step 1.1, 1.2 (M) | O-RU transmits to O-DU its SM capabilities. O-DU decides on a common set of O-DU/O-RU SM capabilities to utilize during operation. | | +| Step 1.3, 1.4 (M) | O-DU transmits information about the available O-DU/O-RU SM capabilities to Non-RT RIC/SMO and Near-RT RIC, including minimal operational information. | | +| Step 2.1, 2.2 (M), 2.3 (O) | Data collection request from SMO to E2 Nodes (M) and external entities (O) for training. | | +| Step 2.4, 2.5 (M), 2.6 (O) | Data collection from E2 Nodes (M) and external entities (O) for training in SMO. | | +| Step 2.7 (M) | Non-RT RIC retrieves data for training. | | +| Step 2.8, 2.9 (M), 2.10 (O) | Data collection request from Near-RT RIC to E2 Nodes (M) and external entities (O) for inference. | | +| Step 2.11, 2.12 (M), 2.13 (O) | Data collection from E2 Nodes (M) and external entities (O) to Near-RT RIC for inference. | | +| Step 3.1, 3.2, 3.3 (M) | Based on continuous/periodically collected data, Non-RT RIC trains the AI/ML model and deploys it to Near-RT RIC via O1/O2. Near-RT RIC performs inference using the AI/ML model. | | +| Step 4.1 (M) | Near-RT RIC provides SM utilization guidance via E2 to O-DU. | | +| Step 4.2, 4.3 (O), | O-DU considers Near-RT RIC's SM utilization guidance in its updated scheduling strategy and O-RU applies SM selection internally. | | +| Step 4.4, 4.5, 4.6 (O) | Based on Near-RT RIC's SM utilization guidance, O-DU alternatively selects a SM, O-DU requests a new SM configuration by O-RU over O-FH and O-RU applies the new SM configuration. | | +| Ends when | Operator disables or changes targets for SM utilization guidance xApp. | | +| Exceptions | None identified. | | +| Post-conditions | Near-RT RIC/Non-RT RIC continues to monitor the energy consumption and efficiency and the RAN performance by collecting and monitoring the relevant data over E2/O1. | | + +``` + +@startuml +skinparam defaultFontSize 12 +autonumber + +Box "SMO" #gold + Participant "Collection & Control" as COLL + Participant "Non-RT RIC" as NON +End box + +Box "O-RAN" #lightpink + Participant "Near-RT RIC" as NEAR + Participant "O-CU" as OCU + Participant "O-DU" as ODU +End box + +Box "O-RU" #turquoise + Participant "O-RU" as ORU +End box + +Box "EXT" #lightcyan + Participant "EXT" as EXT +End box + +== Initialization == +autonumber 1.1 + ORU -> ODU : <> SM capabilities + ODU -> ODU : SM capability decision + ODU -> COLL : <> SM capability information exposure + ODU -> NEAR : <> SM capability information exposure + +== Data Collection == +autonumber 2.1 + +Group Data for training + COLL -> OCU : <> Data collection request + COLL -> ODU : <> Data collection request + COLL -> EXT : Data collection request + OCU -> COLL : <> Data retrieval + ODU -> COLL : <> Data retrieval + EXT -> COLL : Data retrieval + COLL -> NON : Data retrieval +End group +Group Data for inference + NEAR -> OCU : <> Data collection request + NEAR -> ODU : <> Data collection request + NEAR -> EXT : Data collection request +Loop + OCU -> NEAR : <> Data retrieval + ODU -> NEAR : <> Data retrieval + EXT -> NEAR : Data retrieval +End Group +End Loop + +== AI/ML Flow == +autonumber 3.1 + NON -> NON : AI/ML model training + NON -> NEAR : <> AI/ML model deployment +Loop + NEAR -> NEAR: AI/ML model inference +End Loop + +== SM Guidance (Loop) == +autonumber 4.1 + NEAR -> ODU: <> Guidance to utilize SM + +group Configuration Update + group alt1 + ODU -> ODU: Updated scheduling strategy + end +end + +``` + +``` + ORU -> ORU: Internal SM selection +end +group alt2 + ODU -> ODU: SM selection + ODU -> ORU: <> Request new \nSM configuration + ORU -> ORU: Apply new SM configuration +end +@enduml +``` + +![Sequence diagram for SM Selection in the Near-RT RIC, ML model training in the Non-RT RIC. The diagram shows interactions between SMO, O-RAN (Near-RT RIC, O-CU, O-DU), O-RU, and EXT. It includes phases for Initialization, Data Collection, AI/ML Flow, and SM Guidance (Loop).](9eef0972d4326f7548c7f66eaaa66f3a_img.jpg) + +``` + +sequenceDiagram + participant SMO as SMO +Collection & Control +Non-RT RIC + participant O_RAN as O-RAN +Near-RT RIC +O-CU +O-DU + participant O_RU as O-RU +O-RU + participant EXT as EXT +EXT + + Note over O_RAN: Initialization + O_RU->>O_RAN: 1.1 <> SM capabilities + O_RAN->>O_RU: 1.2 SM capability decision + O_RAN->>SMO: 1.3 <> SM capability information exposure + O_RAN->>O_RAN: 1.4 <> SM capability information exposure + + Note over O_RAN: Data Collection + SMO->>O_RAN: 2.1 <> Data collection request + SMO->>O_RAN: 2.2 <> Data collection request + SMO->>O_RAN: 2.3 Data collection request + O_RAN->>SMO: 2.4 <> Data retrieval + O_RAN->>SMO: 2.5 <> Data retrieval + O_RAN->>SMO: 2.6 Data retrieval + O_RAN->>SMO: 2.7 Data retrieval + + Note over O_RAN: Data for inference + O_RAN->>O_RAN: 2.8 <> Data collection request + O_RAN->>O_RAN: 2.9 <> Data collection request + O_RAN->>O_RAN: 2.10 Data collection request + O_RAN->>O_RAN: loop + O_RAN->>O_RAN: 2.11 <> Data retrieval + O_RAN->>O_RAN: 2.12 <> Data retrieval + O_RAN->>O_RAN: 2.13 Data retrieval + + Note over O_RAN: AI/ML Flow + O_RAN->>SMO: 3.1 AI/ML model training + SMO->>O_RAN: 3.2 <> AI/ML model deployment + O_RAN->>O_RAN: loop + O_RAN->>O_RAN: 3.3 AI/ML model inference + + Note over O_RAN: SM Guidance (Loop) + O_RAN->>O_RAN: 4.1 <> Guidance to utilize SM + alt alt1 + O_RAN->>O_RAN: 4.2 Updated scheduling strategy + O_RAN->>O_RU: 4.3 Internal SM selection + alt alt2 + O_RAN->>O_RAN: 4.4 SM selection + O_RAN->>O_RU: 4.5 <> Request new SM configuration + O_RU->>O_RAN: 4.6 Apply new SM configuration + end + +``` + +Sequence diagram for SM Selection in the Near-RT RIC, ML model training in the Non-RT RIC. The diagram shows interactions between SMO, O-RAN (Near-RT RIC, O-CU, O-DU), O-RU, and EXT. It includes phases for Initialization, Data Collection, AI/ML Flow, and SM Guidance (Loop). + +Figure 7.2.2.1-1: Flow diagram for SM Selection in the Near-RT RIC, ML model training in the Non-RT RIC + +#### 7.2.2.2 O-RAN Entity Roles + +##### 1) SMO (including Non-RT RIC) + +- a) Receive common SM capability information and additional operational parameters from O-DU. +- b) Subscribe to and retrieve necessary performance indicators (incl. Energy Efficiency KPIs), measurement reports and RAN configurations from E2 Nodes via the O1 interface for the purpose of AI/ML model training and performance monitoring. +- c) Perform AI/ML model training and deployment. +- d) Optionally, i) collect enrichment information from Application servers and associate enrichment information with collected measurements and configurations, ii) collect prediction or optimization related information from other rApps. + +##### 2) Near-RT RIC (xApp) + +- a) Receive common SM capability information and additional operational parameters from O-DU. +- b) Subscribe to and retrieve necessary performance indicators (incl. Energy Efficiency KPIs), measurement reports, UE context information, RAN configurations, and SM usage data from E2 Nodes via the E2 interface for the purpose of AI/ML model inference, and performance monitoring. +- c) Optionally, i) collect enrichment information from Application servers and associate enrichment information with collected measurements and configurations, ii) collect prediction or optimization related information from other xApps (Near-RT RIC internally) or rApps. +- d) Send SM utilization guidance via a policy message for Sleep Mode optimization to E2 Nodes via the E2 interface. + +##### 3) E2 Nodes (O-DU in disaggregated architecture) + +- a) Support retrieving the O-RU SM capabilities and additional operational parameters from O-RU via O-FH. +- b) Support reporting the common O-DU/O-RU SM capabilities and additional operational parameters to Near-RT RIC over E2 and to SMO over O1. +- c) Support reporting of necessary performance indicators (incl. Energy Efficiency KPIs), measurement reports, UE context information, RAN configurations, and SM usage data with required granularity to Near-RT RIC via the E2 interface and SMO via the O1 interface. +- d) Receive SM utilization guidance via policy message from the Near-RT RIC via the E2 interface. +- e) Adjust scheduling strategy (to allow O-RU to internally update its used SMs configuration) or alternatively perform SM selection based on SM utilization guidance received from the Near-RT RIC. +- f) Optionally, request O-RU over O-FH to update its used SM configuration (e.g., switch off a certain O-RU functionality). + +##### 4) O-RU + +- a) Support reporting the O-RU SMs capabilities and additional operational parameters to O-DU via O-FH. +- b) Internally apply SM selection or alternatively receive over O-FH and apply O-DUs request for updated SM configuration (e.g., switch off a certain O-RU functionality). + +#### 7.2.2.3 Void + +## 7.3 Impact Analysis on O-RAN Work Groups + +This is an initial impact analysis as part of the WG1 UCTG Network Energy Saving work on Advance Sleep Mode Selection use case. The intention is to estimate the expected standardization effort within the O-RAN working groups. It is up to the WGs to decide how Advance Sleep Mode Selection use case functionality should be specified in specifications of each WG. + +| # | WGs/FGs | Spec. No | Objective description | +|---|--------------------------|--------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | WG1 (Use case) | O-RAN.WG1.NES-USE-CASES-TR
O-RAN.WG1.Use-Cases-Detailed-Specification | Update WG1 NES use case analysis report and use-case detailed specification with Advance Sleep Mode Selection use case. No impact to existing architecture | +| 2 | WG2 (Non-RT RIC, A1, R1) | O-RAN.WG2.R1GAP
O-RAN.WG2.R1UCR
O-RAN.WG2.R1TD (TBD) | Updates to R1 services and procedures for Advanced Sleep Mode Selection use case | +| | | O-RAN.WG2.Non-RT-RIC-ARCH | Reviewing procedures to implement Advanced Sleep Mode Selection use case and generate corresponding A1 policies/updates of O1 and O2-related services via R1 interface, if any. | +| | | O-RAN.WG2.Use-Case-Requirements | Specifying Advanced Sleep Mode Selection use case and its requirements in WG2 UCR specification | +| | | O-RAN.WG2.A1GAP
O-RAN.WG2.A1TD | Reviewing requirement for policy driven implementation of Advance Sleep Mode Selection | +| 3 | WG3 (Near-RT RIC, E2) | O-RAN.WG3.UCR | Specifying Advanced Sleep Mode Selection use case and its requirements in WG3 UCR specification | +| | | O-RAN.WG3.RICARCH | No impact identified | +| | | O-RAN.WG3.E2GAP | No impact identified | +| | | O-RAN.WG3.E2AP | No impact identified | +| | | O-RAN.WG3.E2SM-RC or
NEW: O-RAN.WG3.E2SM-CC | Identify and specify RAN E2 actions necessary for implementation of Advance Sleep Mode Selection from E2 Node towards O-RU. | +| | | O-RAN.WG3.E2SM-KPM | Identify and specify RAN E2 measurement required analysis of ES and EC for Advance Sleep Mode Selection through Near-RT RIC | +| 4 | WG4 (O-FH) Impact | O-RAN.WG4.MP | Identify the relevant impacts on M-Plane for both hierarchical and hybrid model to accommodate management features requirements towards O-RU. Define O-RU Energy efficiency KPIs and counters. | +| | | O-RAN-WG4.CUS | Identify the relevant impacts on CUS-Plane and data model to support various Advance Sleep Mode Selection use case. | +| 5 | WG5 (O1) Impact | O-RAN.WG5.O-DU-O1
O-RAN.WG5.O-CU-O1
O-RAN.WG5.MP | Identify specific O-DU operational and data model aspects of the feature content including the interface between SMO and O-DU, and the one between SMO and O-CU. Make appropriate changes to the O-DU data model and other WG5 specifications as needed. | +| 7 | WG7 | WG7 Energy Savings TR | WG7 needs to provide reference architecture of O-RU which supports Advance Sleep Mode Selection use case. | + +| | | | | +|---|------|--------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------| +| 8 | WG10 | O-RAN.WG10.O1-Interface
O-RAN.WG10.OAM-Architecture
O-RAN.WG10.Information Model and Data Models | Identify the relevant impacts on O1 interface to support Advanced Sleep Mode Selection use cases and IM/DM to capture requirements. | +|---|------|--------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------| + +## 7.4 Relation and Impact on 3GPP Specifications + +Within the 3GPP Rel.18 RAN WG1 led study item on network energy saving 3GPP agreed on three Power States for evaluation purpose Micro, Light and Deep Sleep as documented in TR 38.864 [19]. The states represent a simplified model for simulation and evaluation purpose only and have not been part of the normative work in Rel.18. The examples of Advanced Sleep Modes are shown in Annex D. + +| Reference | Release | Title | Documentation and impact on Specifications | +|-------------------|-----------|----------------------------------------|--------------------------------------------------| +| FS_Netw_Energy_NR | 5G Rel.18 | Study on network energy savings for NR | Results will be captured in 3GPP TR 38.864 [19]. | + +3GPP TSG RAN 98-e approved a new Rel.18 WID: Network energy savings for NR (RP-223540) which includes following objective. + +2. *Specify enhancement on cell DTX/DRX mechanism including the alignment of cell DTX/DRX and UE DRX in RRC\_CONNECTED mode, and inter-node information exchange on cell DTX/DRX [RAN2, RAN1, RAN3]* + - *Note: No change for SSB transmission due to cell DTX/DRX.* + - *Note: The impact to IDLE/INACTIVE UEs due to the above enhancement should be avoided.* + +While 3GPP standards concentrate on enhancing the co-ordination between UE and gNB for cell DTX/DRX operation, O-RAN Advanced Sleep Mode Selection focuses on co-ordinating O-RU and O-DU based on Non-RT/Near-RT RIC policy. + +## 7.5 Void + +## 7.6 Feasibility Analysis + +### 7.6.1 Impact to Continuous Operation during Advance Sleep Modes + +Advanced Sleep Modes that are limited to symbol level are not expected to have a significant impact on user performance. However, longer sleep modes that involve shutting down more components or reducing their activity for longer periods of time may impact user performance such as increased latency and/or reduced data transfer rates. + +### 7.6.2 Impact to Coverage + +If an O-RU transmission is suspended temporarily (e.g., some kind of deep sleep modes), UEs may be unable to connect to gNB due to missing synchronization, measurements and/or system information, hence the coverage in the area may be impacted. The impact might be mitigated by intelligent configuration and/or using multiple carriers. + +### 7.6.3 Impact and Relation to Vendor Specific Scheduling Algorithms + +O-RU and O-DU may implement their own sleep modes. However, adjustments may be needed to align with ES/EE policies from Non-RT/Near-RT RIC. Operators need to balance user/cell performance against energy savings, and E2 Nodes (O-DU/O-CU) may require additional functionality to implement these policies. + +### 7.6.4 Limited O-RU/O-DU Capabilities + +The O-RU and O-DU may have limitations in terms of implementing sleep modes capabilities. It is up to implementation how many Advanced Sleep Modes are supported in O-RU or O-DU. Furthermore, the generic solution should support the transmission of operational parameters from O-RU to O-DU, e.g., minimum duration of activation of SMs, transition times between sleep modes, whether to be applied on UL/DL, etc. + +# 8 O-Cloud Resource Energy Saving Mode + +In O-RAN split option 7.2x major signal processing is performed by O-DU and O-CU. Hence, O-DU and O-CU hardware components consume energy to maintain a certain level of system availability even in case of low or no traffic load on VNFs or CNFs. As more and more operators adopt virtualized or containerized architecture, there is a strong need to have solution(s) for energy saving in the O-Cloud. The O-Cloud Resource Energy Saving Mode use case should cover various components of the O-Cloud such as CPU/GPU, accelerators, NIC cards and other components at node level. + +The aim of this use case is to enable energy savings in the O-Cloud by reducing the power consumption of various O-Cloud components without impairing the network performance. Given the network status, the O-Cloud components' power consumption can be optimized through actions such as adaptive shutdown of hardware, scaling out Network Functions, and optimization of CPU/FPGA power, memory usage, CPU frequency, etc. By using multi-dimensional data (e.g., traffic load data at E2 Nodes, load over O-Cloud in terms of compute/storage) the Non-RT RIC can configure changes towards the O-Cloud. + +The time scale for the control of O-Cloud Resource Energy Saving Mode solutions is Non-Real Time. + +## 8.1 Sub Use Case 1: O-Cloud Node Shutdown + +### 8.1.1 Problem Statement, Solution and Value Proposition + +This use case describes a method to perform O-Cloud Energy Saving by shutting down physical O-Cloud Node(s) in idle times through Non-RT RIC. + +When O-Cloud Node is operating at low load, then the deployed Network Functions or its microservices can be relocated or shut down or blocked from starting on the node in order to free up the node. Moving VNFs or CNFs within O-Cloud and/or evacuating the O-Cloud Nodes are O-Cloud internal functionalities which might be triggered by the SMO. + +Idle O-Cloud Nodes can be shut down to reduce energy consumption during low-load times. Non-RT RIC subscribes to O2 data via SMO, which, among others, includes configuration of O-Cloud Nodes (e.g., K8s cluster, resource pools, NF-pod-node associations). Non-RT RIC provides guidance to the SMO. The SMO monitors O-Cloud and E2 Node resources based on O1/O2 data and requests shut down (scale in) or add O-Cloud resources via O2ims (scale out) based on Non-RT RIC guidance. O-Cloud (IMS) will estimate if sufficient O-Cloud resources are remaining or are available to serve respective requests. After execution or rejection of respective requests O-Cloud (IMS) will communicate its actions via O2ims. + +![Figure 8.1.1-1: O-Cloud energy saving by O-Cloud pod relocation and node shutdown. The diagram illustrates a two-step process. Step 1, 'Network Function relocation', shows a single 'NF' pod in 'O-Cloud Node 1' being moved to 'O-Cloud Node 2', which now contains two 'NF' pods. Step 2, 'O-Cloud Node Shutdown', shows 'O-Cloud Node 1' becoming empty after the pod is relocated. The final state shows 'O-Cloud Node 2' with two 'NF' pods and 'O-Cloud Node 1' as an empty box, indicating it can be shut down.](d9b5a2ee4b5cb3b0aa74c5b02322fcb3_img.jpg) + +Figure 8.1.1-1: O-Cloud energy saving by O-Cloud pod relocation and node shutdown. The diagram illustrates a two-step process. Step 1, 'Network Function relocation', shows a single 'NF' pod in 'O-Cloud Node 1' being moved to 'O-Cloud Node 2', which now contains two 'NF' pods. Step 2, 'O-Cloud Node Shutdown', shows 'O-Cloud Node 1' becoming empty after the pod is relocated. The final state shows 'O-Cloud Node 2' with two 'NF' pods and 'O-Cloud Node 1' as an empty box, indicating it can be shut down. + +**Figure 8.1.1-1: O-Cloud energy saving by O-Cloud pod relocation and node shutdown** + +A Node is the smallest unit of a computing hardware, such as a physical or virtual machine. Programs running on Nodes are packaged as containers. One or more containers form a structure are called a pod. A pod might comprise functionalities supporting one or multiple cells or parts of one or multiple cells. As shown in Figure 8.1.1-1, O-Cloud Node 1 has one VNF pod deployed which can be relocated to the O-Cloud Node 2, which would make O-Cloud Node 1 idle. Post relocation of the VNF pod, the idle O-Cloud Node 1 can be shut down to reduce energy consumption. + +Non-RT RIC will use O1 and O2 data to provide guidance for shutdown decision. For example, O-Cloud resource utilization matrices such as CPU, memory, and storage utilization can be analyzed by using O-Cloud Monitoring Service telemetry. Such data can be correlated with RAN related load and energy consumption information obtained per Network Function via the O1 interfaces. + +### 8.1.2 Architecture/Deployment Option + +Background information on O-Cloud architecture and management: Federated O-Cloud Orchestration and Management (FOCOM), Network Function Orchestrator (NFO), Infrastructure Management Services (IMS) and Deployment Management Services (DMS) are defined in O-RAN.WG6.O2-GA&P [20]. The FOCOM is responsible for accounting and asset management of the resources in the cloud. The NFO is responsible for orchestrating the assembly of the network functions as a composition of NF deployments in the O-Cloud. The IMS is responsible for management of the O-Cloud resources and the software which is used to manage those resources, and the DMS is responsible for management of NF deployments into the O-Cloud. + +In this deployment option, decision making for O-Cloud Node Shutdown configuration and guidance, potentially including AI/ML model training and inference, is done at the SMO/Non-RT RIC. The overall mechanism is shown in Figure 8.1.2-1. + +Image: O-RAN ALLIANCE Logo + +O-RAN.WG1.NESUC-R003-v02.00![](628bbd7300dbe4e1226c3937a9674d19_img.jpg) + +SMO Text Box + +**SMO** + +- 1) Receive guidance from Non-RT RIC for optimizing energy consumption for O-Cloud resource evacuation and shutdown. +- 2) Provide optimized configuration for O-Cloud resource evacuation and shutdown towards O-Cloud. + +Non-RT RIC (rApp) Text Box + +**Non-RT RIC (rApp)** + +- 1) Collect O-Cloud FCAPS data via SMO over O2/R1. +- 2) Collect E2 Node data via SMO over O1/R1. +- 3) Train & Deploy AI/ML Model to generate guidance based on O1 and O2 data. +- 4) Generate guidance for O-Cloud configuration based on priority, load and energy consumption. + +O-Cloud Text Box + +**O-Cloud** + +- 1) Expose O2 (IMS/DMS) data towards SMO. +- 2) Apply configuration provided by SMO, e.g., execute Node evacuation/shutdown. +- 3) Communicate its action towards SMO/Non-RT RIC. + +Diagram Graphic Representation + +Service, Management & Orchestration + + +O-Cloud ES Guidance + +FOCOM + +NFO + +Non-Real Time RIC & rApp + +O2-IMS +O2-DMS +O1 +A1 + +IMS + +DMS + +O-Cloud + +Near-RT RIC + +E2 + +E2 Node + +Open FH M-Plane + +O-RU + +Figure 8.1.2-1: Cloud Resource Energy Saving via SMO/Non-RT RIC + +© 2023 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. +80 + +#### 8.1.2.1 Description and UML Diagram + +**Table 8.1.2.1-1: O-Cloud Node Shutdown: AI/ML inference via Non-RT RIC** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Shutting down O-Cloud Nodes during idle times or low load scenario for energy saving purpose. | | +| Actors and Roles |
  • - SMO (FOCOM): Receives guidance from Non-RT RIC and generates optimized configurations towards O-Cloud.
  • - SMO (NFO): Receives guidance from Non-RT RIC and generates optimized configurations towards O-Cloud.
  • - Non-RT-RIC (rApp): Trains AI/ML models and generates guidance.
  • - O-Cloud (IMS): Executes changes recommended by SMO/FOCOM.
  • - O-Cloud (DMS): Executes changes recommended by SMO/NFO.
| | +| Assumptions |
  • - The "Service Request" from Non-RT RIC to the FOCOM includes the identifiers of the O-Cloud Node(s) to be evacuated or shut down.
  • - The "Service Request" from Non-RT RIC to the NFO includes the identifiers of the NFs to be modified.
  • - Non-RT RIC (rApp) subscribed to receive notifications from SMO.
  • - SMO (FOCOM and NFO) gets guidance from Non-RT RIC (rApp).
| | +| Pre-conditions |
  • - All relevant functions and components are instantiated and available.
  • - Non-RT RIC can receive configurations, load and performance measurements from E2 Nodes via O1 and telemetry data from O-Cloud via O2.
  • - O-Cloud ensures that relocation of NF pod from one Node to another Node does not impair network services.
  • - O-Cloud ensures that NF Pod shutdown does not impair network services related to that NF.
| | +| Begins when | The operator has enabled or has set targets for O-Cloud Node Shutdown. | | +| Step 1.1, 1.2, 1.3, 1.4 (M) | Network Function (applications) related data is subscribed to and received over O1 interface, for example traffic load of NF, NF utilization, NF energy consumption etc. | | +| Step 2.1, 2.2, 2.3, 2.4, 2.5, 2.6, 2.7, 2.8 (M) | O-Cloud utilization matrices (such as CPU, Memory, Storage utilization) and NF placement are acquired by Non-RT RIC from O-Cloud via SMO framework over O2 interface. | | +| Step 3.1, 3.2 (O) | Non-RT RIC trains the AI/ML models with the collected data. Trained AI/ML models are deployed and activated in the Non-RT RIC. Non-RT RIC constantly monitors performance and energy consumption of the O-Cloud Nodes, NF deployments, as well as cell load related and traffic data, EE/EC measurement reports etc. | | +| Step 4.1, 4.2, 4.3, 4.4, 4.5, 4.6 (M) | Non-RT RIC provides guidance to FOCOM and NFO to modify NF deployments and to evacuate the specific O-Cloud Node(s).
NFO requests the DMS over O2dms to modify NF deployment.
FOCOM requests the IMS using O2ims interface to evacuate one or more O-Cloud Nodes after modification (shutdown, relocation etc.) of NF deployments. | | +| Step 5.1, 5.2, 5.3 (O) | IMS notifies SMO that the O-Cloud Node(s) evacuation is completed (or rejected). | | +| Step 6.1, 6.2, 6.3, (M) | Non-RT RIC provides guidance to FOCOM, then FOCOM configures IMS to shutdown Node(s). | | +| Step 7 (M) | IMS shuts down the requested O-Cloud Node(s). | | +| Step 8.1, 8.2, 8.3 (M) | IMS notifies SMO that O-Cloud Node(s) shut down is completed. | | +| Ends when | O-Cloud Node(s) have been shut down. | | +| Exceptions | None identified. | | +| Post-conditions | O-Cloud Node(s) may be shut down for energy saving.
SMO/Non-RT RIC continues to monitor the load on the O-Cloud and RAN data by collecting and monitoring the relevant performance and matrices using O1 and O2. | | + +``` + +@startuml +skinparam defaultFontSize 12 +autonumber +Box "O-Cloud Platform" #lightseagreen + participant "IMS" as IMS + participant "DMS" as DMS +End box +Box "Service Management & \n Orchestration Framework" #gold + Participant "FOCOM" as FOCOM + Participant "NFO" as NFO + Participant "OAM Functions" as OAM + Participant " Non-RT RIC & rApp" as nRT +End box +Box "O-RAN" #lightpink + Participant "E2-Nodes" as E2N +End box + +== O1 & O2 Data Collection == +autonumber 1.1 +note over nRT,OAM +User traffic load on NF(O-DU/O-CU), NF(O-DU/O-CU)Resource utilization etc. data to +retrieved +End note + nRT -> OAM : Data subscription request +Loop + OAM -> E2N : <>Data subscription request + E2N -> OAM : <>Data Retrieval + OAM -> nRT : Data Retrieval +End Loop +Note over nRT,IMS +O2ims & O2dms telemetry, configurations such as CPU,Memory, Storage utilization,O-Cloud +Node configurations etc +End note +autonumber 2.1 + + nRT -> FOCOM : Data collection request + nRT -> NFO : Data collection request + FOCOM -> IMS : <> Data collection request + NFO -> DMS : <> Data collection request + +Loop + IMS -> FOCOM : <> Data retrieval + DMS -> NFO : <> Data retrieval + FOCOM -> nRT : Data retrieval + NFO -> nRT : Data retrieval +End Loop +== AI/ML Flow == +autonumber 3.1 + nRT -> nRT: AI/ML model training + nRT -> nRT: AI/ML model inference + +== O-Cloud Node Evacuation (Optional) == +Note over nRT,FOCOM +Draning request to be included with necessary O-Cloud Node identifiers +End note +autonumber 4.1 + nRT -> FOCOM: Guidance to evacuate O-Cloud Node + nRT -> NFO: Guidance to modify NF deployment + NFO -> DMS: <> Modify NF deployment + FOCOM -> IMS:<> Evacuate O-Cloud Node +Loop for each \nNF Deployment + DMS -> DMS: NF Modification +End Loop +Loop for each \nO-Cloud Node + IMS -> IMS: Evacuate O-Cloud Node +End Loop +autonumber 5.1 + DMS -> NFO :<> Completion of NF \n deployment modification + IMS -> FOCOM :<> Completion \nof O-Cloud Node Evacuation + +``` + +``` +NFO -> nRT : Notify completion of NF \ndeployment modification +FOCOM -> nRT : Notify completion \nof O-Cloud Node Evacuation + +== O-Cloud Node Shutdown == +Note over nRT , FOCOM +Shutdown request to be included with necessary O-Cloud Node identifiers +End note +autonumber 6.1 + nRT -> FOCOM: Guidance to shutdown O-Cloud node + FOCOM -> IMS: <> Shutdown O-Cloud Node + +autonumber 7 +Loop For each\n O-Cloud Node + IMS -> IMS: Perform shutdown\n of O-Cloud Node +End Loop +autonumber 8.1 + IMS -> FOCOM: :<>Completion of shutdown\n of O-Cloud Node + FOCOM -> nRT: Notify shutdown of O-Cloud Node + +@enduml +``` + +![Flow diagram for O-Cloud Node shutdown. The diagram is divided into three main sections: O1 & O2 Data Collection, AI/ML Flow, and O-Cloud Node Draining (Optional). It shows interactions between the O-Cloud Platform (IMS, DMS), Service Management & Orchestration Framework (FOCOM, NFO, OAM Functions, Non-RT RIC & rApp), and O-RAN (E2-Nodes). The process includes data collection, AI/ML model training and inference, draining of O-Cloud nodes, and finally, the shutdown of O-Cloud nodes.](f11b1040576ac8bdbc2b2ec4ace6eceb_img.jpg) + +**O-Cloud Platform** + +**Service Management & Orchestration Framework** + +**O-RAN** + +**O1 & O2 Data Collection** + +User traffic load on NF(O-DU/O-CU), NF(O-DU/O-CU) Resource utilization etc. data to be retrieved + +1.1 Data subscription request + +loop + +1.2 <>Data subscription request + +1.3 <>Data Retrieval + +1.4 Data Retrieval + +O2ims & O2dms telemetry, configurations such as CPU, Memory, Storage utilization, O-Cloud Node configurations etc + +2.1 Data collection request + +2.2 Data collection request + +2.3 <> Data collection request + +2.4 <> Data collection request + +loop + +2.5 <> Data retrieval + +2.6 <> Data retrieval + +2.7 Data retrieval + +2.8 Data retrieval + +**AI/ML Flow** + +3.1 AI/ML model training + +3.2 AI/ML model inference + +**O-Cloud Node Draining (Optional)** + +Draining request to be included with necessary O-Cloud Node identifiers + +4.1 Guidance to drain O-Cloud Node + +4.2 Guidance to modify NF deployment + +4.3 <> Modify NF deployment + +4.4 <> Drain O-Cloud Node + +loop [for each NF Deployment] + +4.5 NF Modification + +loop [for each O-Cloud Node] + +4.6 Drain O-Cloud Node + +5.1 <> Completion of NF deployment modification + +5.2 <> Completion of O-Cloud Node Drain + +5.3 Notify completion of NF deployment modification + +5.4 Notify completion of O-Cloud Node Drain + +**O-Cloud Node Shutdown** + +Shutdown request to be included with necessary O-Cloud Node identifiers + +6.1 Guidance to shutdown O-Cloud node + +6.2 <> Shutdown O-Cloud Node + +loop [For each O-Cloud Node] + +7 Perform shutdown of O-Cloud Node + +8.1 <> Completion of shutdown of O-Cloud Node + +8.2 Notify shutdown of O-Cloud Node + +Flow diagram for O-Cloud Node shutdown. The diagram is divided into three main sections: O1 & O2 Data Collection, AI/ML Flow, and O-Cloud Node Draining (Optional). It shows interactions between the O-Cloud Platform (IMS, DMS), Service Management & Orchestration Framework (FOCOM, NFO, OAM Functions, Non-RT RIC & rApp), and O-RAN (E2-Nodes). The process includes data collection, AI/ML model training and inference, draining of O-Cloud nodes, and finally, the shutdown of O-Cloud nodes. + +Figure 8.1.2.1-1: Flow diagram for O-Cloud Node shutdown + +#### 8.1.2.2 O-RAN Entity Roles + +##### 1) Non-RT RIC (rApp) + +- a) Collect configurations, performance indicators and power consumption information from E2 Nodes and O-Cloud Nodes via SMO, for the purpose of decision making, optionally using training and inference of AI/ML models that assist such EE/ES functions. +- b) Collect O-Cloud configuration data from O2 via SMO / from FOCOM and from NFO including policies applied to O-Cloud. +- c) Provide guidance towards FOCOM to evacuate or shut down O-Cloud Nodes. +- d) (Optionally) Deploy, update, configure and trigger execution of EE/ES AI/ML models. + +##### 2) E2 Node + +- a) Report KPIs and measurements related to load and power consumption information to SMO via O1 interface. + +##### 3) O-Cloud (DMS) + +- a) Report NF deployment information to SMO via O2dms interface. +- b) Apply NF deployment configurations received over O2dms. +- c) Provide feedback on NF deployment modification actions. + +##### 4) O-Cloud (IMS) + +- a) Report infrastructure and deployment telemetry data to SMO via O2 interface. For example, O-Cloud Node configuration, health status, server memory utilization and I/O load overtime, CPU, network, and memory usage. +- b) Apply configurations received over O2ims related to O-Cloud Node draining and shutdown as part of O-Cloud energy saving optimization. +- c) Provide feedback post completion or non-completion of actions to SMO. + +##### 5) SMO (NFO) + +- a) Collect the necessary configurations and NF deployment data from O-Cloud triggered by Non-RT RIC and forward information towards Non-RT RIC. +- b) Decide about optimized O-Cloud deployment configuration based on guidance received from Non-RT RIC to modify NF deployments. Send optimized O-Cloud deployment configuration to O-Cloud via O2dms interface. +- c) Monitor the NF deployment of O-Cloud NF via O2dms and report to Non-RT RIC. + +##### 6) SMO (FOCOM) + +- a) Collect the necessary configurations, performance indicators, and measurement reports data from O-Cloud triggered by Non-RT RIC and forward information towards Non-RT RIC. +- b) Decide about optimized O-Cloud configuration based on guidance received from Non-RT RIC to evacuate or shut down O-Cloud Nodes. Send optimized O-Cloud Node configuration to O-Cloud via O2ims interface. +- c) Monitor the performance of O-Cloud Nodes via O2ims and report to Non-RT RIC. + +#### 8.1.2.3 Void + +### 8.1.3 Impact Analysis on O-RAN Work Groups + +No detailed impact analysis has been conducted during this study. + +NOTE 8.1-1 should be resolved by WG6 during normative phase. + +### 8.1.4 Relation and Impact on 3GPP Specifications + +No specific relation and impact on 3GPP specifications have been identified during the study. + +### 8.1.5 Void + +### 8.1.6 Feasibility Analysis + +#### 8.1.6.1 Service Continuity during NF relocation + +NF pod relocation between cluster nodes involves shutting down the NF pod on its original node and starting a new NF pod on another node. In order to avoid impairment of the network performance and service continuity, it has to be guaranteed that all functionalities and traffic allocated to the original NF pod are reallocated before shutdown. + +#### 8.1.6.2 Pooling vs. Scaling Gains + +Nodes can be shut down only if all pods running on them are shut down. O-Cloud Node Shutdown will result in concentration of pods on a fewer number of nodes, which also decreases resiliency and robustness. + +#### 8.1.6.3 Start-up Time for Scale Out Operation + +Scale out operation after node shutdown involves startup of several pieces of hardware, initialization of its operating system and virtualization layers, configuring it as a cluster node, and adding it to the cluster as a node. Overall, this sequence of procedures can take several minutes. Therefore, Energy Saving procedures and resiliency/robustness procedures are to be optimized jointly. + +**NOTE 8.1-1:** To be assessed by WG6, how fast reconfigurations of the O-Cloud Node Shutdown by SMO / Non-RT RIC can be applied in the O-Cloud and if there is any specific requirement. + +## 8.2 Sub Use Case 2: O-Cloud CPU Energy Saving Mode + +### 8.2.1 Problem Statement, Solution and Value Proposition + +This use case describes a method of O-Cloud Energy Saving in which preferred CPU Energy Saving modes can be configured by SMO/Non-RT RIC. CPU Energy Saving modes, implemented by the vendor or standardized, may correspond to different CPU energy saving states (related to, e.g., CPU frequency, voltage, certain sleep modes) that can be controlled externally for CPU Power Management. O-Cloud might for instance be configured with a range (or utilization factor) of allowed or suggested CPU Energy Saving modes. O-Cloud is allowed to do fast adaptations of the CPU Energy Saving modes autonomously (e.g., based on instantaneous load of one or multiple CPUs) within that range. Alternatively, O-Cloud might be configured with a maximum CPU Energy Saving mode. O-Cloud is allowed to select among Energy Saving modes up to the maximum O-Cloud Energy Saving mode autonomously. By this, energy savings can be maximized, while still limiting the impact on QoS/user experience (e.g., potential latency impact on user plane traffic). The operator is allowed to control and tune O-Cloud energy saving gains versus O-Cloud performance. + +Examples for CPU Energy Saving modes are the control of CPU frequency/voltage (P-state) and/or certain C-state of the O-Cloud Node CPUs as explained in the following. + +#### **CPU frequency (P-State):** + +P-States provide a way to scale the CPU frequency and voltage to reduce the power consumption of the CPU. The number of available P-States can vary with the type of CPU, even those from the same family, or one can change the corresponding frequency of the CPU. P-states can typically be limited or disabled in a system's firmware such as UEFI/BIOS. + +Frequency of the CPU (P-State) can be dynamically changed based on the load on the O-Cloud Node and thus O-Cloud Node energy consumption can be modified. The decision to select a desired CPU frequency (P-State) can be done by examining the current operational CPU frequency (P-State), CPU utilization and other related O2 and O1 (Traffic) telemetry from the O-Cloud instance. + +P-State or CPU Frequency can be changed for the whole CPU (all cores) as well as for individual cores of a CPU. + +#### **C-State:** + +C-States are usually starting in C0, which is the normal CPU operating mode, i.e., the CPU is 100% turned on. With increasing CNumber, the CPU sleep mode is deeper, i.e., more circuits are turned off and more time is required to return the CPU back to C0 mode, i.e., to wake-up. Each mode is named individually and several of them have sub-modes with different power saving and thus wake-up time levels. + +Example C-states: + +- C0 is the operational state, meaning that the CPU is 100% turned on. +- C1 is the first idle state. +- C2 is the second idle state. + +At the O-Cloud Node CPU level, power usage can be controlled in various ways. One way is by controlling the C-State of the CPU in CPE idle condition. C-States reflect the capability of an idle processor to turn off unused components to save power. + +The decision of desired C-State must consider the NF deployment distribution on the O-Cloud instance and might involve consolidating the deployments on the limited set of O-Cloud Nodes based on O2 telemetry analysis such as CPU utilization, memory utilization, etc. + +C-State can be changed at the CPU level, or at the individual core level of that CPU. + +### 8.2.2 Architecture/Deployment Option + +In this deployment option, decision making for CPU Energy Saving Mode utilization control, potentially including AI/ML Model Training and Inference, is done at the Non-RT RIC. The overall mechanism is shown in Figure 8.2.2-1. + +![Figure 8.2.2-1: O-Cloud CPU Energy Saving Mode via SMO/Non-RT RIC. The diagram illustrates the architecture and data flow for CPU energy saving mode control. It shows the interaction between the Service, Management & Orchestration (SMO) layer, the Non-RT RIC (rApp) layer, the O-Cloud layer, and the Near-RT RIC layer. The SMO layer contains FOCOM and NFO. The Non-RT RIC (rApp) layer contains the Non-Real Time RIC & rApp. The O-Cloud layer contains IMS, DMS, and E2 Node. The Near-RT RIC layer contains the Near-RT RIC. The O-Cloud layer is connected to the Near-RT RIC via O2-IMS, O2-DMS, O1, and A1 interfaces. The Near-RT RIC is connected to the E2 Node via E2 and Open FH M-Plane interfaces. The E2 Node is connected to the O-RU via Open FH M-Plane. The SMO layer is connected to the Non-RT RIC (rApp) via O-Cloud ES Guidance. The Non-RT RIC (rApp) is connected to the O-Cloud layer via O2-IMS, O2-DMS, O1, and A1 interfaces. The O-Cloud layer is connected to the Near-RT RIC via O2-IMS, O2-DMS, O1, and A1 interfaces. The Near-RT RIC is connected to the E2 Node via E2 and Open FH M-Plane interfaces. The E2 Node is connected to the O-RU via Open FH M-Plane.](17158c6bfd9aa2dfd2551d218ac337e7_img.jpg) + +**SMO** + +- 1) Receive guidance from NonRT RIC for optimizing CPU Energy Saving Mode. +- 2) Provide optimized configuration for CPU Energy Saving Mode towards O-Cloud. + +**Non-RT RIC (rApp)** + +- 1) Collect O-Cloud FCAPS data via SMO over O2/R1. +- 2) Collect E2 Node data via SMO over O1/R1. +- 3) Generate guidance/configuration (NOTE 0-1, NOTE 8.2-2) based on O1 and O2 data for CPU Energy Saving Mode control based on priority, load and energy consumption. + +**O-Cloud** + +- 1) Expose O2 (IMS/DMS) data toward SMO/Non-RT RIC. +- 2) Apply configuration provided by FOCOM in its decision making. +- 3) Communicate its actions towards SMO/Non-RT RIC. + +**Service, Management & Orchestration** + +O-Cloud ES Guidance + +FOCOM + +NFO + +Non-Real Time RIC & rApp + +O2-IMS + +O2-DMS + +O1 + +A1 + +IMS + +DMS + +O-Cloud + +Near-RT RIC + +E2 + +E2 Node + +Open FH M-Plane + +O-RU + +Figure 8.2.2-1: O-Cloud CPU Energy Saving Mode via SMO/Non-RT RIC. The diagram illustrates the architecture and data flow for CPU energy saving mode control. It shows the interaction between the Service, Management & Orchestration (SMO) layer, the Non-RT RIC (rApp) layer, the O-Cloud layer, and the Near-RT RIC layer. The SMO layer contains FOCOM and NFO. The Non-RT RIC (rApp) layer contains the Non-Real Time RIC & rApp. The O-Cloud layer contains IMS, DMS, and E2 Node. The Near-RT RIC layer contains the Near-RT RIC. The O-Cloud layer is connected to the Near-RT RIC via O2-IMS, O2-DMS, O1, and A1 interfaces. The Near-RT RIC is connected to the E2 Node via E2 and Open FH M-Plane interfaces. The E2 Node is connected to the O-RU via Open FH M-Plane. The SMO layer is connected to the Non-RT RIC (rApp) via O-Cloud ES Guidance. The Non-RT RIC (rApp) is connected to the O-Cloud layer via O2-IMS, O2-DMS, O1, and A1 interfaces. The O-Cloud layer is connected to the Near-RT RIC via O2-IMS, O2-DMS, O1, and A1 interfaces. The Near-RT RIC is connected to the E2 Node via E2 and Open FH M-Plane interfaces. The E2 Node is connected to the O-RU via Open FH M-Plane. + +**Figure 8.2.2-1: O-Cloud CPU Energy Saving Mode via SMO/Non-RT RIC** + +**NOTE 0-1:** The interface between Non-RT RIC and FOCOM is for illustrative purposes, subject to further modification by WG1 ATG architecture specifications. + +**NOTE 0-2:** To be studied by WG2 if rApp has all information from O-Cloud to generate the updated guidance towards FOCOM. + +#### 8.2.2.1 Description and UML Diagram + +**Table 8.2.2.1-1: O-Cloud CPU Energy Saving Mode: AI/ML inference via Non-RT RIC** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Optimizing CPU Energy Saving Mode for power management of the O-Cloud Node CPUs (e.g., to preferably use low power mode when CPU is idle or operating at low load). | | +| Actors and Roles |
  • - SMO/FOCOM: Receives guidance from Non-RT RIC and generates optimized configurations towards O-Cloud.
  • - Non-RT RIC (rApp): Trains AI/ML models and generates guidance.
  • - O-Cloud (IMS): Executes changes recommended by SMO/Non-RT RIC.
| | +| Assumptions |
  • - The "Service Request" to the FOCOM includes the identifiers of the O-Cloud Node(s) to be controlled.
  • - Non-RT RIC (rApp) has subscribed to receive notifications from SMO.
  • - SMO (FOCOM) gets guidance from Non-RT RIC (rApp), where rApp may host the algorithm(s) that determine to control the CPU Energy Saving Mode.
| | +| Pre- conditions |
  • - All relevant functions and components are instantiated and available.
  • - Non-RT RIC can receive configurations, load, performance measurements from RAN nodes via the O1 and telemetry data from O-Cloud via O2.
  • - Changes of the CPU Energy Saving Mode(s) within the O-Cloud are enabled from O-Cloud Node BIOS/UEFI.
| | +| Begins when | The operator has enabled or has set targets for this CPU Energy Saving Mode control. | | +| Step 1.1, 1.2, 1.3 (M) | Collection of traffic load and utilization and RAN configurations related Network function (O-DU and O-CU) data over O1 interface. | | +| Step 2.1, 2.2, 2.3, 2.4, 2.5, 2.6, 2.7, 2.8 (M) | O-Cloud Node telemetry and inventory, for example CPU utilization, supported and currently used CPU Energy Saving Mode etc. over O2 interface to be acquired from SMO. | | +| Step 3.1, 3.2 (O) | Non-RT RIC optionally trains the AI/ML models with the collected data. Trained AI/ML models are deployed and activated in the Non-RT RIC. Non-RT RIC constantly monitors RAN performance and energy consumption of the O-Cloud Nodes for inference; for example, load related and traffic information, EE/EC measurement reports, CPU, Memory, Storage utilization, etc. | | +| Step 4.1, 4.2 (M) | Non-RT RIC provides guidance to FOCOM, then FOCOM configures IMS with preferred CPU Energy Saving Mode(s) for the CPU of O-Cloud Node(s).

NOTE: CPU cores of specific O-Cloud Node might be identified in guidance or O2 configuration. | | +| Step 5 (M) | IMS applies optimized CPU Energy Saving Mode of each O-Cloud Node to the configured CPU Energy Saving Mode. | | +| Step 6.1, 6.2, 6.3 (M) | IMS notifies SMO and SMO notifies Non-RT RIC that change of Energy Saving Mode utilization is completed. | | +| Ends when | CPU Energy Saving Mode has been changed. | | +| Exceptions | None identified. | | +| Post-conditions | Based on the load on the O-Cloud Nodes, the desired CPU Energy Saving mode is changed. Thus, CPU Energy Saving mode (e.g., CPU frequency (P-State) and/or C-State of CPU) is optimized for or energy saving purposes. | | + +``` + +@startuml +autonumber +Box "O-Cloud Platform" #lightseagreen + participant "IMS" as IMS + participant "DMS" as DMS +End box +Box "Service Management & \n Orchestration Framework" #gold + Participant "FOCOM" as FOCOM + Participant "NFO" as NFO + Participant "OAM " as OAM + Participant "NonRT RIC" as nRT +End box +Box "O-RAN" #lightpink + Participant "E2-Nodes" as E2N +End box + +== O1 & O2 Data Collection == +autonumber 1.1 +note over nRT,OAM +User Traffic Load, RAN configurations related to Network functions (O-DU & O-CU) data to +be retrieved +End note + + nRT -> OAM : Data subscription request +Loop + OAM -> E2N : <> Data subscription request + E2N -> OAM : <> Data retrieval + OAM -> nRT : Data retrieval +End Loop +Note over nRT,IMS +O2ims & O2dms telemetry & inventory such as supported CPU Energy Saving Modes and status, +CPU utilization, current operational CPU Power, Frequency, Voltage etc of O-Cloud node to +be retrieved +End note +autonumber 2.1 + + nRT -> FOCOM : Data collection request + FOCOM -> IMS : <> Data collection request + nRT -> NFO : Data collection request + NFO -> DMS : <> Data collection request +Loop + IMS -> FOCOM : <> Data retrieval + DMS -> NFO : <> Data retrieval + FOCOM -> nRT : Data retrieval + NFO -> nRT : Data retrieval +End Loop +== AI/ML Flow == +autonumber 3.1 + nRT -> nRT: AI/ML model training + nRT -> nRT: AI/ML model inference + +== CPU Energy Saving Mode Optimization == +autonumber 4.1 + nRT -> FOCOM: Guidance of CPU Energy Saving Mode + FOCOM -> IMS: <> Configure CPU Energy Saving Mode + +autonumber 5 +Loop For each O-Cloud Node + IMS -> IMS: Perform Change of CPU Energy Saving Mode +End Loop +autonumber 6.1 + IMS -> FOCOM: <> Notify change of CPU Energy Saving Mode of O-Cloud Node + FOCOM -> nRT: Notify change of CPU Energy Saving Mode of O-Cloud Node +@enduml + +``` + +![Flow diagram for O-Cloud CPU Energy Saving Modes showing interactions between O-Cloud Platform, Service Management & Orchestration Framework, and O-RAN components.](c0bba4421681d4d0e7f7f58549f97556_img.jpg) + +The diagram illustrates the flow for O-Cloud CPU Energy Saving Modes, involving three main entities: O-Cloud Platform (teal), Service Management & Orchestration Framework (yellow), and O-RAN (pink). + +**O-Cloud Platform Components:** IMS, DMS. + +**Service Management & Orchestration Framework Components:** FOCOM, NFO, OAM, NonRT RIC. + +**O-RAN Component:** E2-Nodes. + +**01 & 02 Data Collection** + +- User Traffic Load, RAN configurations related to Network functions (O-DU & O-CU) data to be retrieved +- 1.1 Data subscription request (OAM to NonRT RIC) +- 1.2 <> Data subscription request (NonRT RIC to OAM) +- 1.3 <> Data retrieval (NonRT RIC to OAM) +- 1.4 Data retrieval (OAM to NonRT RIC) + +**O2ims & O2dms telemetry & inventory such as supported CPU Energy Saving Modes and status, CPU utilization, current operational CPU Power, Frequency, Voltage etc of O-Cloud node to be retrieved** + +- 2.1 Data collection request (OAM to NonRT RIC) +- 2.2 <> Data collection request (NonRT RIC to OAM) +- 2.3 Data collection request (NonRT RIC to OAM) +- 2.4 <> Data collection request (NonRT RIC to OAM) +- 2.5 <> Data retrieval (OAM to NonRT RIC) +- 2.6 <> Data retrieval (OAM to NonRT RIC) +- 2.7 Data retrieval (NonRT RIC to OAM) +- 2.8 Data retrieval (OAM to NonRT RIC) + +**AI/ML Flow** + +- 3.1 AI/ML model training (NonRT RIC to OAM) +- 3.2 AI/ML model inference (NonRT RIC to OAM) + +**CPU Energy Saving Mode Optimization** + +- 4.1 Guidance of CPU Energy Saving Mode (OAM to NonRT RIC) +- 4.2 <> Configure CPU Energy Saving Mode (NonRT RIC to OAM) +- 5 Perform Change of CPU Energy Saving Mode (OAM to NonRT RIC) +- 6.1 <> Notify change of CPU Energy Saving Mode of O-Cloud Node (NonRT RIC to OAM) +- 6.2 Notify change of CPU Energy Saving Mode of O-Cloud Node (OAM to NonRT RIC) + +**Loop [For each O-Cloud Node]** + +- 5 Perform Change of CPU Energy Saving Mode + +Flow diagram for O-Cloud CPU Energy Saving Modes showing interactions between O-Cloud Platform, Service Management & Orchestration Framework, and O-RAN components. + +Figure 8.2.2.1-1: Flow diagram for O-Cloud CPU Energy Saving Modes + +#### 8.2.2.2 O-RAN Entity Roles + +##### 1) Non-RT RIC (rApp) + +- a) Collect configurations, performance indicators and power consumption information from SMO, E2 Nodes and O-Cloud Nodes, for the purpose of decision making, optionally using training and inference of AI/ML models that assist such EE/ES functions. +- b) Collect O-Cloud configuration data from FOCOM including supported CPU Energy Saving Modes and planned policies or configuration changes towards O-Cloud. +- c) Collect O-Cloud configuration data from NFO including NF deployment configuration and planned policies and configuration changes towards O-Cloud. +- d) Provide guidance to FOCOM to change CPU Energy Saving Mode. +- e) (Optional) Deploy, update, configure and trigger execution of EE/ES AI/ML models. + +**NOTE 0-3:** Framework and procedure for guidance from Non-RT RIC to NFO/FOCOM within SMO to be studied in WG1 ATG. + +##### 2) E2 Node + +- a) Report KPIs and measurements related to load and power consumption information to SMO via O1 interface. + +##### 3) O-Cloud (including IMS and DMS) + +- a) Report infrastructure telemetry data to SMO via O2 interface, for example O-Cloud Node health status, server memory utilization and I/O load over time and deployment telemetry data like CPU, network, and memory usage etc. +- b) Apply configurations received over O2ims related to CPU Energy Saving Mode. +- c) Provide feedback post completion or non-completion of actions to SMO and/or to Non-RT RIC through SMO. + +##### 4) SMO (FOCOM/NFO) + +- a) Collect the necessary configurations, performance indicators, and measurement reports data from RAN nodes and O-Cloud triggered by Non-RT RIC and forward information towards Non-RT RIC. +- b) Decide about optimized O-Cloud configuration based on guidance received by Non-RT RIC to optimize CPU Energy Saving Mode utilization. Send optimized O-Cloud Node configuration to O-Cloud via O2ims interface. +- c) Monitor the performance of O-Cloud Nodes via O2ims and RAN Network functions via O1; when the optimization objective fails, initiate fall-back procedure; meanwhile, trigger the AI/ML model re-training, data analytics and optimization in Non-RT RIC. + +#### 8.2.2.3 Void + +### 8.2.3 Impact Analysis on O-RAN Work Groups + +No detailed impact analysis has been conducted during this study. + +NOTE 8.2-1 through NOTE 8.2-4 shall be resolved by WG1 ATG, WG2 and WG6 during normative phase. + +### 8.2.4 Relation and Impact on 3GPP Specifications + +No specific relation and impact on 3GPP specifications have been identified during the study. + +### 8.2.5 Void + +### 8.2.6 Feasibility Analysis + +#### 8.2.6.1 Not to Restrict Fast CPU Energy Saving Mode Switching + +O-Cloud has instantaneous knowledge about O-Cloud resource and energy consumption and is therefore capable of fast adaptations. Moreover, different energy saving features might be available and run on different time scales, with different latency requirements. SMO/Non-RT RIC configurations should not restrict the O-Cloud from utilizing other (faster) energy saving features in case those are deemed optimal in the given context and decrease the energy consumption. + +**NOTE 8.2-4:** To be assessed by WG6, how fast reconfigurations of the CPU Energy Saving Mode by SMO/FOCOM can be applied in the O-Cloud, and if there is any specific requirement. + +# 9 Summary and Conclusion + +In the O-RAN WG1 UCTG Network Energy Saving pre-normative phase, Network Energy Saving use cases have been analyzed. This Technical Report presents the results of the pre-normative phase Network Energy Saving work item. + +Carrier and Cell Switch Off/On is a technique which enables turning off cells/carriers in case there is no load/UEs in the respective cell/carrier, and the neighboring cells/carriers can take over the expected additional load. The algorithm to trigger off/on switching may be hosted in the Non-RT RIC or in the Near-RT RIC. Performance, load, resource utilization, and energy/power consumption related KPIs are forwarded to the RIC from the E2 Nodes and O-RUs, and the RIC-based applications determine recommendations for cells/carriers to be switched off (energySavingState). Ultimately, the switch-off operations are performed by the E2 Node (O-CU) since additional critical operations are required which are handled by the O-CU. While for the Non-RT RIC deployment all input/output parameters are existing, enhancements to the E2 interface are required when the algorithm is hosted by the Near-RT RIC. Numerical analysis shows a high potential of this energy saving technique for overall Network Energy Saving. No challenges on feasibility have been identified. Carrier and Cell Switch Off/On is suggested for normative standardization with the foreseen impact on O-RAN WGs as outlined in Section 5.3. + +RF Channel Reconfiguration is a technique which enables O-RU to be requested to perform Tx/Rx Array selection. At low load, i.e., when the expected traffic volume or number of connected users are lower than the configured threshold, the power consumption of O-RUs can be reduced by switching off certain Tx/Rx arrays. For example, 32 out of 64 Tx/Rx Arrays of an O-RU can be switched off in a digital mMIMO architecture. The algorithm to trigger RF Channel Reconfiguration may be hosted in the Non-RT RIC or in the Near-RT RIC. Respective KPIs are collected by the Near-RT/non-RT RIC from the E2 Nodes and O-RUs, to be used by the xApps/rApps to determine recommendations for RF Channel Reconfiguration to be executed by the E2 Nodes. Numerical analysis shows a large potential of this energy saving technique for overall Network Energy Saving. Some feasibility aspects are listed in Section 6.6 which should be considered during normative phases in relevant WGs. RF Channel Reconfiguration is suggested for normative standardization with the foreseen impact on O-RAN WGs as outlined in Section 6.3. + +Advanced Sleep Modes typically refer to standardized or implementation specific intelligent energy saving techniques in the RAN. The Advanced Sleep Mode Selection use case is a technique which achieves more granular energy saving by optimizing the range of allowed sleep modes in the O-DU/O-RU via RIC-based guidance. Two architecture/deployment options have been identified, 1) Training and Inference in Non-RT RIC, and 2) Training in Non-RT RIC and Inference in Near-RT RIC. In both options, the Non-RT RIC retrieves the E2 Node Sleep Mode capabilities over O1 and R1 via SMO, collects the necessary data from the E2 Nodes and trains an ML model, which is then deployed: for option 1) in the rApp, and for option 2) in the Near-RT RIC (xApp). In option 1) inference of the optimized Sleep Mode utilization range is provided as guidance by the rApp, while in option 2) by the Near-RT RIC (xApp). Some feasibility aspects are listed in Section 7.6 which should be considered during normative phases in relevant WGs. Advanced Sleep Mode Selection is suggested for normative standardization with the foreseen impact on O-RAN WGs as outlined in Section 7.3. + +O-Cloud Resource Energy Saving Mode comprises a set of techniques which enable energy savings in the O-Cloud by reducing the power consumption of various O-Cloud components without impairing the network performance. Two sub use cases have been identified, O-Cloud Node Shutdown and O-Cloud CPU Energy Saving Mode. The O-Cloud Node Shutdown use case is a method for reducing O-Cloud energy consumption by focusing NF deployments on a fewer number of (physical) O-Cloud Nodes and thereby potentially freeing up physical resources. Thereafter, shutting down the idle physical nodes is achieved through guidance from Non-RT RIC to FOCOM. The O-Cloud CPU Energy Saving Mode use case is a method for reducing the O-Cloud energy consumption by guiding the available CPU-internal energy saving states via guidance provided + +by Non-RT RIC to FOCOM. Some feasibility aspects are listed in Section 8.1.6 and Section 8.2.6, respectively, which should be considered during normative phases in relevant WGs. O-Cloud Resource Energy Saving Mode is suggested for normative standardization with the foreseen impact on O-RAN WGs as outlined in Section 8.1.3 and Section 8.2.3. + +Implementation of NES features should ensure stable and conflict-free network operation. Ideas on design principles for NES applications facilitating appropriate conflict mitigation are outlined in Annex A. + +O-RAN O1 interfaces are used for exchange of data for analysis and provisioning of configuration changes in the O-RAN Nodes. How Network Energy Saving use cases utilize the O1 interface for such purpose is described in Annex C in a generic way. + +# Annex A (Informative): Design Principles for NES Features + +Efficient and stable utilization of NES features requires an intelligent automation and optimization framework, leveraging on collected KPIs and data analytics with AI/ML algorithms. The SMO, the Non-RT RIC and the Near-RT RIC have an essential role in orchestrating energy saving mechanisms across the overall RAN infrastructure. Network operators should be able to control each NES feature at SMO level, for instance by scheduling the activation and deactivation of such features over pre-defined time periods. Intelligent management and orchestration of O-CU, O-DU and O-Cloud resources are required. For example, optimized traffic steering will allow for a dynamic adaptation of active hardware resources. + +NES features will differ in their algorithmic solutions with respect to the considered scales, both temporal and spatial. In order to harmonize different features, first a concise scale evaluation is required. + +The higher the number of different NES features being deployed in a radio network, the higher the probability of conflicts between actions initiated by individual NES solutions. These kinds of conflicts can be minimized or avoided by either by a respective conflict coordination entity controlling the actions of each NES function during activation, or by an appropriate design of the NES functions facilitating conflict free coexistence, e.g., by deploying NES solutions with diverging time scales. + +Currently rApp conflict management is not specified in O-RAN. Therefore, it may be investigated whether the xApp conflict mitigation approach could be expanded to apply for rApps as well. Furthermore, definition of rules for conflict mitigation – to be derived from the design guidelines – is essential. + +## Scales of Energy Saving Algorithms + +Three different scales of energy saving algorithms are identified: + +### 1. Decoupled case + +In this case locality in time and (network) space is assumed which leads to local decision-making. Stability of operation is ensured by appropriately chosen hysteresis values. Decoupled NES features are investigated with respect to their potential of being overruled by non-local optimization algorithms. Example use cases are carrier and cell switch on/off and RF channel re-configuration. + +### 2. Non-locality in time + +Such an algorithm requires a robust forecast. Traffic load is considered being the principal steering basis for this kind of NES features. A generic traffic forecast with statistical guarantees as a generally available feature is essential. This information should be available in the SMO, and not in a dedicated rApp/xApp. An example use case would be switching off network entities during the night. + +### 3. Non-locality in space + +Earlier research showed the energy saving potential of nearest-neighbour handover algorithms in order to shut off specific cells. Coverage and capacity distinction will assure MNO's legal obligations and product considerations. + +## Solution approach + +Temporal and spatial scales of NES solutions need to be specified by App vendors. Concurrent update intervals in capturing the respective data lead to placing the respective Apps in the Non-RT RIC or the Near-RT RIC. App “twins” are possible. + +## Detecting and Gauging Potential Conflicts + +In order to achieve scale-separation and conflict-free optimization hierarchies, NES features have to be charted and given a measure for their potential to figure in non-local optimization strategies. This measure derives from nearest-neighbour interaction of the feature and HW-induced hysteresis requirements. Decoupled NES features are investigated with respect to their potential of being overruled by non-local optimization algorithms (see above). + +Potential conflict and instability cases are for instance switching oscillations, SON-like conflicts between different AI/ML procedures for NES features, or SON-like conflicts between NES features and other use cases (e.g., QoE Optimization, Traffic Steering, Massive MIMO Beamforming Optimization, ...). + +## Design Guidelines + +Stability of network operation is key and to be considered first in place. Thus, non-local NES features with inherent instability risks according to the above analysis are to be deprioritized. To that end, proposed Apps are to be evaluated with regard to operational destabilization, and appropriate measures are to be derived. + +Secondly the outcome, i.e. the potential for optimization, is to be taken into account. Off-line studies equip MNOs with aggregate estimates of NES effects within the representative time and space intervals. An NES feature with a higher potential of energy savings should overrule those with lower energy saving ability. + +Appropriate harmonization between different Apps is essential. MNOs may derive criteria for rApps/xApps in order to ensure conflict-free energy saving hierarchies which App vendors are encouraged to comply to. Prior study work regarding conflict resolution in SON can be used to harmonize AI/ML Apps with different cost functions (use cases) but overlapping or identical action spaces. + +# Annex B (Informative): Load profile and O-RU functional blocks + +Generally, it is up to the operator to define a load distribution profile reflecting the situation in the network. For the calculation of the average power/energy consumption, weighting factors based on a daily (24 hours) load distribution profile given in Table C-1 as described in ETSI ES 202 706-1 [10] has been used. + +**Table B-1: Load level durations for daily average calculation** + +| | Low load | Medium load | Busy hour load | +|--------------|----------|-------------|----------------| +| Duration/day | 6 hours | 10 hours | 8 hours | + +In Figure B-1 through B-4 as described in ORAN.WG7.OMAC-HAR [17], high-level functional block diagrams for an 4T4R/8T8R and mMIMO O-RUs are shown, depicting the major HW/SW components. Accordingly, the power consumption can be roughly categorized into the following parts: + +1. Digital Processing Unit +2. RF Processing Unit +3. FH Processing Unit +4. Power Unit & Other Components + +![Figure B-1: Generic O-RU7-2x Functional Module Diagram of 4T4R/8T8R. This block diagram shows the internal architecture of an O-RU. On the left, an 'Optical interface to/from O-DU_{2x}' connects to the 'ORAN Fronthaul Processing Unit (C, U, S, M plane)', which includes 'eCPRI, (De-) Compression, Optical, Security'. This unit connects via a 'Packet interface' to the 'Digital Processing Unit' containing 'DFE N x Tx/Rx' (with '(De-) Compression, Low-Phy, DDC, DUC, CFR, DPD') and 'AFE N x Tx/Rx' (with 'ADC, DAC'). The DFE and AFE are connected by a 'Digital interface'. The AFE connects via an 'RF interface' to the 'RF Processing unit', which includes an 'RF section N x Tx/Rx/ LNA/PA', 'Filter N', and 'Antenna N ports'. The RF section is connected to the filter, which is connected to the antenna ports. A 'Timing' block is connected to the Digital Processing Unit and the RF section. A 'POWER SUPPLY' block is connected to the AFE, the RF section, and the Antenna ports. A dashed box labeled 'Optional integration' encloses the RF section, Filter, and Antenna ports. A 'Tx/Rx Reciprocity CAL Option #3' block is connected to the AFE and the RF section. A 'Tx/Rx Reciprocity CAL Option #1, #2' block is connected to the RF section and the Antenna ports.](65ed1005c1fee99c885dc4ea2f175c20_img.jpg) + +Figure B-1: Generic O-RU7-2x Functional Module Diagram of 4T4R/8T8R. This block diagram shows the internal architecture of an O-RU. On the left, an 'Optical interface to/from O-DU\_{2x}' connects to the 'ORAN Fronthaul Processing Unit (C, U, S, M plane)', which includes 'eCPRI, (De-) Compression, Optical, Security'. This unit connects via a 'Packet interface' to the 'Digital Processing Unit' containing 'DFE N x Tx/Rx' (with '(De-) Compression, Low-Phy, DDC, DUC, CFR, DPD') and 'AFE N x Tx/Rx' (with 'ADC, DAC'). The DFE and AFE are connected by a 'Digital interface'. The AFE connects via an 'RF interface' to the 'RF Processing unit', which includes an 'RF section N x Tx/Rx/ LNA/PA', 'Filter N', and 'Antenna N ports'. The RF section is connected to the filter, which is connected to the antenna ports. A 'Timing' block is connected to the Digital Processing Unit and the RF section. A 'POWER SUPPLY' block is connected to the AFE, the RF section, and the Antenna ports. A dashed box labeled 'Optional integration' encloses the RF section, Filter, and Antenna ports. A 'Tx/Rx Reciprocity CAL Option #3' block is connected to the AFE and the RF section. A 'Tx/Rx Reciprocity CAL Option #1, #2' block is connected to the RF section and the Antenna ports. + +**Figure B-1: Generic O-RU7-2x Functional Module Diagram of 4T4R/8T8R** + +![Figure B-2: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #1. This diagram shows a multi-ported version of the O-RU architecture. It features multiple instances of the 'ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer' (including 'eCPRI, (De-) Compression, Optical, Security') connected via 'Packet interface' to multiple instances of the 'Digital Processing Unit' (containing 'DFE N x Tx/Rx' and 'AFE N x Tx/Rx'). The DFE and AFE are connected by a 'Digital interface'. The AFE connects via an 'RF interface' to multiple instances of the 'RF Processing unit' (containing 'RF section N x Tx/Rx/ LNA/PA', 'Filter N', and 'Antenna N ports'). A 'Timing' block is connected to the Digital Processing Unit and the RF section. A 'POWER SUPPLY' block is connected to the AFE, the RF section, and the Antenna ports. A dashed box labeled 'Optional integration' encloses the RF section, Filter, and Antenna ports. A 'Tx/Rx Reciprocity CAL Option #3' block is connected to the AFE and the RF section. A 'Tx/Rx Reciprocity CAL Option #1, #2' block is connected to the RF section and the Antenna ports. The diagram also shows multiple 'Antenna N ports' and 'Filter N' blocks.](6b7163fd031312df1ebf24ebf8a8ab47_img.jpg) + +Figure B-2: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #1. This diagram shows a multi-ported version of the O-RU architecture. It features multiple instances of the 'ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer' (including 'eCPRI, (De-) Compression, Optical, Security') connected via 'Packet interface' to multiple instances of the 'Digital Processing Unit' (containing 'DFE N x Tx/Rx' and 'AFE N x Tx/Rx'). The DFE and AFE are connected by a 'Digital interface'. The AFE connects via an 'RF interface' to multiple instances of the 'RF Processing unit' (containing 'RF section N x Tx/Rx/ LNA/PA', 'Filter N', and 'Antenna N ports'). A 'Timing' block is connected to the Digital Processing Unit and the RF section. A 'POWER SUPPLY' block is connected to the AFE, the RF section, and the Antenna ports. A dashed box labeled 'Optional integration' encloses the RF section, Filter, and Antenna ports. A 'Tx/Rx Reciprocity CAL Option #3' block is connected to the AFE and the RF section. A 'Tx/Rx Reciprocity CAL Option #1, #2' block is connected to the RF section and the Antenna ports. The diagram also shows multiple 'Antenna N ports' and 'Filter N' blocks. + +**Figure B-2: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #1** + +![Figure B-3: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #2](29981ff643dee2929c47fe2c72c6dd15_img.jpg) + +Figure B-3 illustrates the High Level System Architecture #2 for mMIMO [NxM]T[NxM]R O-RU. The architecture consists of the following components and interfaces: + +- Optical interface to/from O-DU7.2x**: Connects to the ORAN Fronthaul Processing Unit. +- ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer**: Contains eCPRI, (De-) Compression, Optical, Security, Low-Phy. +- Digital Processing Unit**: Contains DFE & AFE N x Tx/Rx, DDC, DUC, CFR, DPD, ADC, DAC. +- RF Processing unit**: Contains RF section N x Tx/Rx/LNA/PA, Filter N, and Antenna N ports. +- Timing**: Provides timing signals to the ORAN Fronthaul Processing Unit and the RF Processing unit. +- POWER SUPPLY**: Provides power to the ORAN Fronthaul Processing Unit and the RF Processing unit. +- Interfaces**: + - Digital Interface**: Connects the ORAN Fronthaul Processing Unit to the Digital Processing Unit. + - RF Interface**: Connects the Digital Processing Unit to the RF Processing unit. + - Tx/Rx Reciprocity CAL Option #1, #2**: Connects the RF section to the Filter. + - Tx/Rx Reciprocity CAL Option #3**: Connects the Filter to the Antenna. +- Optional Integration**: Indicated by a dashed box around the RF Processing unit. + +Figure B-3: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #2 + +Figure B-3: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #2 + +![Figure B-4: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #3](6c442018ecaaeda3eabb60f36849253c_img.jpg) + +Figure B-4 illustrates the High Level System Architecture #3 for mMIMO [NxM]T[NxM]R O-RU. The architecture consists of the following components and interfaces: + +- Optical interface to/from O-DU7.2x**: Connects to the ORAN Fronthaul Processing Unit. +- ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer**: Contains eCPRI, (De-) Compression, Optical, Security, Low-Phy. +- Digital Processing Unit**: Contains DFE & AFE N x Tx/Rx, (De-) Compression, Low-Phy, DDC, DUC, CFR, DPD, ADC, DAC. +- RF Processing unit**: Contains RF section N x Tx/Rx/LNA/PA, Filter N, and Antenna N ports. +- Timing**: Provides timing signals to the ORAN Fronthaul Processing Unit and the RF Processing unit. +- POWER SUPPLY**: Provides power to the ORAN Fronthaul Processing Unit and the RF Processing unit. +- Interfaces**: + - Packet Interface**: Connects the ORAN Fronthaul Processing Unit to the Digital Processing Unit. + - RF Interface**: Connects the Digital Processing Unit to the RF Processing unit. + - Tx/Rx Reciprocity CAL Option #1, #2**: Connects the RF section to the Filter. + - Tx/Rx Reciprocity CAL Option #3**: Connects the Filter to the Antenna. +- Optional Integration**: Indicated by a dashed box around the RF Processing unit. + +Figure B-4: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #3 + +Figure B-4: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #3 + +# Annex C (Informative): O1 interface principles + +## C.1: Overview + +O-RAN O1 interfaces are used for exchange of data for analysis and provisioning of configuration changes in the O-RAN Nodes (Near-RT RIC, E2 Nodes, O-RUs) required for O-RAN use cases. This informative annex describes the general principles how Network Energy Saving use cases utilize the O1 interface for such purpose in a generic way. + +## C.2: O1 interface usage for data collection + +The following message flow describes the usage of O1 interface of the Performance Assurance Management Services (see in Section 2.3 **Error! Reference source not found.**) for data collection. + +``` +@startuml +Skin rose +skinparam defaultFontSize 12 +autonumber + +Box "Service Management & \n Orchestration Framework" #gold + Participant "SMO" as SMO +End box + +Box "O-RAN Nodes" #lightpink + Participant "O-RAN Node" as ORANNODES + Participant "PerfMetricJob" as JOB +End box + +== Data Collection == +ref over SMO : Decision making on data collection \t + +autonumber 1.1 +SMO -> ORANNODES : <> Data collection job creation\ +\n\t\tNETCONF edit-config create +ref over ORANNODES : Data collection job creation +ORANNODES -> JOB **: Create +loop while the PerfMetricJob is active +JOB <-> ORANNODES: Collect data +JOB -> SMO : <> Report data + +ref over SMO: Process data \t +end + +@enduml +``` + +![Sequence diagram showing O1 interfaces usage for data collection between Service Management & Orchestration Framework (SMO) and O-RAN Nodes.](45ca5b5d3befcf2021e8ad1e9a1fdc42_img.jpg) + +``` + +sequenceDiagram + participant SMO as SMO + participant O-RAN_Nodes as O-RAN Nodes + participant O-RAN_Node as O-RAN Node + participant PerfMetricJob as PerfMetricJob + + SMO->>O-RAN_Nodes: 1.1 <> Data collection job creation +NETCONF edit-config create + activate O-RAN_Nodes + O-RAN_Nodes->>PerfMetricJob: 1.2 Create + activate PerfMetricJob + PerfMetricJob->>O-RAN_Node: 1.3 Collect data + activate O-RAN_Node + O-RAN_Node-->>SMO: 1.4 <> Report data + deactivate O-RAN_Node + PerfMetricJob-->>O-RAN_Nodes: + deactivate PerfMetricJob + O-RAN_Nodes-->>SMO: + deactivate O-RAN_Nodes + + Note over SMO: ref Decision making on data collection + Note over O-RAN_Nodes: ref Data collection job creation + Note over SMO: loop [while the PerfMetricJob is active] + Note over SMO: ref Process data + +``` + +The diagram illustrates the O1 interfaces usage for data collection. It shows the interaction between the Service Management & Orchestration Framework (SMO) and O-RAN Nodes. The SMO initiates the process by sending a request to the O-RAN Nodes for data collection job creation. The O-RAN Nodes then create a PerfMetricJob, which collects data and reports it back to the SMO. The SMO then processes the data and makes decisions on data collection. The process is repeated while the PerfMetricJob is active. + +Sequence diagram showing O1 interfaces usage for data collection between Service Management & Orchestration Framework (SMO) and O-RAN Nodes. + +**Figure C-1: O1 interfaces usage for data collection** + +O1 Interfaces are used in the data collection flow as described below: + +1. In Step 1.1, the Performance Assurance Management Services (see Section 2.3 **Error! Reference source not found.**) are used to initiate performance measurement data collection. SMO, in the role of Performance Assurance MnS Consumer, sends request to O-RAN Nodes, in the role of Performance Assurance MnS Producer, for collection and retrieval of measurement data. The O1 interface for this procedure is described in Section 2.3.3 **Error! Reference source not found.**. The Performance Assurance MnS Consumer may specify the reporting mechanism as data file reporting or data streaming. +2. In Step 1.2, O-RAN Nodes internally perform actions to create data collection job, to collect the requested data. +3. While the data collection job is active, the O-RAN Nodes collect the requested data (in Step 1.3). When the request data is ready, O-RAN Nodes send the collected measurement data to the SMO (in Step 1.4). Depending on the reporting mechanism specified by the SMO in Step 1.1, the O-RAN Nodes shall send the measurement data as data file or data streaming. The O1 interface for this procedure is described in Section 2.3.1 **Error! Reference source not found.** and 2.3.2 **Error! Reference source not found.** respectively. +4. SMO, after the retrieval of the measurement data, may internally perform further processing of the data and decision making required for use case. + +## C.3: O1 interface usage for configuration changes + +The following message flow describes the usage of O1 interface of the Provisioning Management Services (see Section 2.1 **Error! Reference source not found.**) for configuration changes. + +``` +@startuml +Skin rose +skinparam defaultFontSize 12 +autonumber + +Box "Service Management & \n Orchestration Framework" #gold + Participant "SMO" as SMO +End box + +Box "O-RAN Nodes" #lightpink + Participant "O-RAN Node" as ORANNODES +End box + +== Configuration changes == +||| +ref over SMO: Decision making on necessary configuration changes \t + +autonumber 1.1 + +SMO -> ORANNODES: <> NETCONF edit-config create, replace or delete +ref over ORANNODES: Applying configuration changes +SMO <-- ORANNODES: <> NETCONF rpc-reply or + +ref over SMO: Update configuration information \t +||| + +@enduml +``` + +![Sequence diagram showing O1 interfaces usage for configuration changes between Service Management & Orchestration Framework (SMO) and O-RAN Nodes.](4ff1eba818ce089f4258346993d7fb8e_img.jpg) + +``` + +sequenceDiagram + participant SMO as SMO + participant O_RAN_Nodes as O-RAN Nodes + participant O_RAN_Node as O-RAN Node + + SMO-->>O_RAN_Nodes: Configuration changes + Note over SMO: ref Decision making on necessary configuration changes + SMO->>O_RAN_Node: 1.1 <> NETCONF edit-config create, replace or delete + Note over O_RAN_Node: ref Applying configuration changes + O_RAN_Node-->>SMO: 1.2 <> NETCONF rpc-reply or + Note over SMO: ref Update configuration information + +``` + +The diagram illustrates the O1 interfaces usage for configuration changes. It shows two main entities: the Service Management & Orchestration Framework (SMO) and O-RAN Nodes. The SMO is represented by a yellow box, and the O-RAN Nodes are represented by a pink box. The SMO contains an SMO component, and the O-RAN Nodes contain an O-RAN Node component. The process begins with a 'Configuration changes' event. The SMO then performs a 'ref Decision making on necessary configuration changes'. Step 1.1 shows the SMO sending a NETCONF edit-config create, replace or delete request to the O-RAN Node. The O-RAN Node then performs a 'ref Applying configuration changes'. Step 1.2 shows the O-RAN Node sending a NETCONF rpc-reply or response back to the SMO. Finally, the SMO performs a 'ref Update configuration information'. + +Sequence diagram showing O1 interfaces usage for configuration changes between Service Management & Orchestration Framework (SMO) and O-RAN Nodes. + +**Figure C-2: O1 interfaces usage for configuration changes** + +O1 Interfaces are used in the configuration changes as described below: + +1. In Step 1.1, the Provisioning Management Services (see Section 2.1 **Error! Reference source not found.**) are used to modify the parameters. SMO, in the role of Provisioning MnS Consumer, sends the request to configure parameters to the O-RAN Nodes, in the role of Provisioning MnS Producer, using the O1 interface described in Section 2.1.3 **Error! Reference source not found.**. +2. The changes are applied to the O-RAN Nodes. O-RAN Nodes may internally update the configurations across internal nodes. +3. In Step 1.2, O-RAN Nodes send the response to the SMO using the O1 interface described in Section 2.1.3 **Error! Reference source not found.** to indicate the result of the operation in Step 1.1. +4. SMO may read the values of the configuration parameters at any time using the O1 interface described in Section 2.1.5 **Error! Reference source not found.** and may subscribe to notification using the O1 interface described in Section 2.1.10 **Error! Reference source not found.** to receive notifications related to any changes to the configuration parameters with the O1 interface described in Section 2.1.9 **Error! Reference source not found.**. +5. SMO may internally update the configuration information across internal nodes. + +# --- Annex D (Informative): Examples of Advanced Sleep Modes + +The O-RAN specifications may be able to offer the flexibility to support different types of O-RUs with varying sleep mode capabilities, including the number of sleep modes available, their depth, and wake-up times. These sleep modes may range from shallow modes such as Symbol and Slot to deeper modes like Radio Frame or even longer durations in seconds. Depending on the sleep mode, different entities might be in control of selection. For instance, O-RU may internally execute Symbol to Slot level sleep modes, while O-DU might be responsible for controlling sleep modes from Slot to Radio Frame. Furthermore, Non-RT or Near-RT RIC may provide the operational range of Sleep Mode selection or may provide control for longer sleep modes. + +Within the 3GPP Rel.18 study item on Network Energy Savings for NR, the following power states have been captured in Section 5.1 of 3GPP TR 38.864 [19] for evaluation purpose. Energy consumption mode for BS: + +1. Micro sleep power state with instantaneous (i.e. per symbol basis) transition time +2. Light sleep power state with transition times between 6 ms and 640 ms +3. Deep sleep power state with transition times between 50 ms to 10 sec + +# Revision history + +| Date | Revision | Description | +|------------|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.02.07 | 01.00.01 |

Removed v01.00 history
Initial version towards v02.00
Agreed CR captured:

  • - NOK-2023.01.24-ORAN-CR-0037-UC4_CPUPowerModes_WG6_WG2_ATG_Feedback_v02.docx
  • - NOK-2023.01.26-ORAN-CR-0038-UC4_OCloud_NodeShutdown_WG2_ATG_WG6_Feedback_v02.docx

NOTE: This version contains the following agreed CRs which have not been reflected in v01.00 publication.

  • - NOK-2022.09.19-ORAN-CR-0009-UC4_O-Cloud Energy Saving Modes v07.docx
  • - NOK-2022.09.19-ORAN-CR-0008-UC4_O-Cloud Node Shutdown v02.docx
| +| 2023.03.07 | 01.00.02 |

Agreed CR captured:

  • - VIA.AO-2023.02.28-ORAN-CR-0040-Conclusions for Phase 2_v01.docx
  • - VIA.AO-2023.02.28-ORAN-CR-0039-Editorial Corrections for Phase 2_v02.docx
  • - VIA-2023.03.02-ORAN-CR-0041-Editorial Corrections for UC1-2_v01.docx
  • - RMI.AO-2023.03.02-ORAN-CR-0038-UseCase3_Advance Sleep Modes_v03.docx
  • - NOK-2023.02.23-ORAN-CR-0036-UC3_ASMOptimization_DeploymentOption1_v03.docx
  • - NOK-2023.02.23-ORAN-CR-0035-UC3_ASMOptimization_DeploymentOption2_v03.docx

Editorial corrections

| +| 2023.03.10 | 01.00.03 |

Voided Section 7.2.1.3, 7.2.2.3, 7.2.5, 8.1.2.3, 8.1.5, 8.2.2.3, 8.2.5
Editorial corrections
Clean version for WG1 approval

| +| 2023.03.22 | 01.00.04 |

Captured WG1 review comments

  • - Table 7.2.1.1-1: Corrected extra node “Non”
  • - “Energy Savings decision making function” and “configuration enforcement function” corrected as “inference host for Energy Savings decision making” and “the subject of action for configuration enforcement”
  • - Editorial corrections
| +| 2023.03.23 | 02.00 | Clean version for TSC approval and publication | + +## History + +| Date | Revision | Description | +|------------|----------|--------------------| +| 2022.11.19 | 01.00 | v01.00 publication | +| | | | +| | | | +| | | | \ No newline at end of file diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/009314d991a0bb3dd5a6093017b094ad_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/009314d991a0bb3dd5a6093017b094ad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bf0a527a0778fb2d16647a149708481cd477b6cd --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/009314d991a0bb3dd5a6093017b094ad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f385847e43abc5e6c16a32e6cdcecb3e0787cd3da9849c013f5c606217838a02 +size 4065 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/05bb679f635c5a18dac76d4a4f21d07d_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/05bb679f635c5a18dac76d4a4f21d07d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..683ebcd5f5f45739ba75ef041874550dc3ef0e1f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/05bb679f635c5a18dac76d4a4f21d07d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b773d0910ca5945c15985ad456f47879fbc751cf4e8f5a69a8057eb6401525ae +size 4063 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/1080f6fcceb1b06309d52abdda5551ef_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/1080f6fcceb1b06309d52abdda5551ef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..689b963d240e07ad81d10f1987a9c46ae43dd777 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/1080f6fcceb1b06309d52abdda5551ef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ccdbd6c2c4ae3349fbaeb42e0f5c1d9c0a5ba2d88007dd3d1b98e68d4b1e6336 +size 90513 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/17b3d3e9bb0c5e4b0545a40379a36494_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/17b3d3e9bb0c5e4b0545a40379a36494_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1cdb4e388705d82c4913de8133d2ccef43e21a02 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/17b3d3e9bb0c5e4b0545a40379a36494_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:97e1791364a0cad1dab04c1b6d1a9f665d73c3f55d92b7a19fe0c10abd040c3d +size 4044 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/2710f8dcbd3b68f655fa86aef2ab4a2a_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/2710f8dcbd3b68f655fa86aef2ab4a2a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a0fe3967c94eb799024d630e822c43b4d8978727 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/2710f8dcbd3b68f655fa86aef2ab4a2a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:503ddfe3e8ccf6e80337ef86abbd8029f752747dd644168100bcb76df2260787 +size 147490 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/3a8ced9dd8e56b154bf4ba860661cd10_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/3a8ced9dd8e56b154bf4ba860661cd10_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..11ee6941c74b388894efe37385a4740543aabaa0 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/3a8ced9dd8e56b154bf4ba860661cd10_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e093dbea016b2b9862c95bafc07e7dff1395575a6b614a71b2379a595e6c3474 +size 65173 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/3bf05e15fc285dd760ca38d290a5e87b_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/3bf05e15fc285dd760ca38d290a5e87b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d43c0a2e008a70da70e933f4ac1b1d3a0d985e78 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/3bf05e15fc285dd760ca38d290a5e87b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:07e2ebed22f7eac08dd632730e4c79abe88566a1f7b7f848b789b035ab4791a8 +size 47662 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/711f84033566e82bde67f2d385ef2cbe_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/711f84033566e82bde67f2d385ef2cbe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8280a3f0de61ad18d94b2eddc77e5a925c6fa37c --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/711f84033566e82bde67f2d385ef2cbe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:babc610810dc9042704581e489f37e4a0017680cfb8219e0ee19809b6df2765d +size 176461 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/765f110eb024d18a875bfed64a97e462_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/765f110eb024d18a875bfed64a97e462_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5bcd1e7f357815c8272366a3dc223c730e5f747f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/765f110eb024d18a875bfed64a97e462_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f26150cb793494c0366d57a26205b14207b9494c229db9723d1e8e7102bfa673 +size 161302 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/7e4a8f5b2ab7ef515f096bae596071b5_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/7e4a8f5b2ab7ef515f096bae596071b5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8933f978fd62f78b60fc1ddba353e236c1a7e9f9 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/7e4a8f5b2ab7ef515f096bae596071b5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:65eb6c5c13cce70df1e24ef7493e9b28afaad08d4dc9560a8b6ed666ff0cfa94 +size 3831 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/858d3c51e73607179c74012f0d66b679_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/858d3c51e73607179c74012f0d66b679_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..186843aa87f7d25a141d6ebecf0f4d91f39422a9 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/858d3c51e73607179c74012f0d66b679_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b882f5d7297b37a5b06308960d8c7e08c7ee4bbb5f8c8743448b2975af933df0 +size 4136 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/8fe38b0370b903ca42cb063805ca34f9_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/8fe38b0370b903ca42cb063805ca34f9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..67d1e1910bd6fc91eb472ced0430f333f6928427 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/8fe38b0370b903ca42cb063805ca34f9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ed05a30a060af3820c5021695cca552f52431e21e7b46326a32550c3def98d8b +size 4065 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/9d18912fa12655384ea0a05c76dc9e1d_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/9d18912fa12655384ea0a05c76dc9e1d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9a4b0e9927b3f279b9d24d39483265847d418443 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/9d18912fa12655384ea0a05c76dc9e1d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:af9ff5d77ae8ca1c8773cd6def1ad6e9613d17d7435d07da646e309147fa2e15 +size 50196 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/a4b2fdcb199a60adc33b3c99192f2028_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/a4b2fdcb199a60adc33b3c99192f2028_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..731c30550f4e0c068e35f6f694d7def3ffc71b7f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/a4b2fdcb199a60adc33b3c99192f2028_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a130ab60144ab1df8778c2bd18e1aa53baffc7a400b6684121074e9f0747ab86 +size 63303 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/a88af50a99b0f157e34bf16a31a4cb0a_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/a88af50a99b0f157e34bf16a31a4cb0a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..be08745f4f760bb493a2cbb151df877485f2fe4c --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/a88af50a99b0f157e34bf16a31a4cb0a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9958b093d28dfcc747770f2dcb6a2c62b5959da9bfe16ad88df2e8e4d8c05fe +size 154022 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/a96acae994afddb6e8afdf33166dc4e5_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/a96acae994afddb6e8afdf33166dc4e5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7c663ed868987adc0a81d0c36d0cc50bc8c2ad8f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/a96acae994afddb6e8afdf33166dc4e5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c07126e22e85c8b63350e9374fa5ecc4862bd004e631101390c94d759904005 +size 217069 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b0debcaa99ed0ff7a501fbfeb2af3f97_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b0debcaa99ed0ff7a501fbfeb2af3f97_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d488b17f2e755f0adb112fc5f175a2f53bfda02e --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b0debcaa99ed0ff7a501fbfeb2af3f97_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:13459bfa8960cc49d734bb62fcce4bfa51c06748a4ad8392848e5f991fde5e7d +size 32284 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b1e01cf3eb34bf2d796d681411c8a107_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b1e01cf3eb34bf2d796d681411c8a107_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c49ab60238c2c8aea7229c48889b57de55d913fa --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b1e01cf3eb34bf2d796d681411c8a107_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:95b4a59eb7c994616cfc281518b95f95283ef7f065cce3e1565ce0647dd4efd9 +size 66953 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b63ac5aadf6cbac66c8a34c1fbc95400_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b63ac5aadf6cbac66c8a34c1fbc95400_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..936a0920e293fe7b1cbb75a62d9f9e0b0173e7de --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b63ac5aadf6cbac66c8a34c1fbc95400_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7f46080dc6442c62453fb2450f5c77fe1f45053450a75acc7b1cd56ff3f83aae +size 60540 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b72db10b33c41380881098c8f0ba2003_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b72db10b33c41380881098c8f0ba2003_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8eeda37884950ae0ecbb295ba9fdc5bcf0e7f16d --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/b72db10b33c41380881098c8f0ba2003_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fa1183411c8abda99b8f9758daf2214df927d180b7be89e4091fbfc308d09ef1 +size 4064 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/bb383139c47d9296247dbab9a475f148_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/bb383139c47d9296247dbab9a475f148_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4a8ec08b481a78b789ffdb8300ddbd59a43385a8 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/bb383139c47d9296247dbab9a475f148_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cdc5c23ab5c87c7ab90d2df3fa7097ece9a49097ec5a5224280fbfbc886f28b +size 4063 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/d01978c5fb4e0374182da4ff635e5576_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/d01978c5fb4e0374182da4ff635e5576_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e602b50e19523ca5298d68087e725b2420b943 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/d01978c5fb4e0374182da4ff635e5576_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:28619303a064b1ba83b6bd4c5d36dec7d4a376054d6ba0e4f8dc30d06d1fe712 +size 82047 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/d04d5c55ee66b731eb8c5f3d8d3c24cb_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/d04d5c55ee66b731eb8c5f3d8d3c24cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..46123b38582b7b398a5166286965cb83f90a053f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/d04d5c55ee66b731eb8c5f3d8d3c24cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c0314e1a363cc693f9a2ac75c9fecb8462c683160a1ef8b3f5ac54f79cb681f8 +size 78418 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/d6bac19d6278fb077736c828621dbd0b_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/d6bac19d6278fb077736c828621dbd0b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a165aa7a9d87f6d8d84dd3e7434b8b93a9412573 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/d6bac19d6278fb077736c828621dbd0b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5ca35a5f915b06ab5fae163e4a0ca8f98bd90f3b1b479a207ce8fabd6cf8ae0f +size 49890 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/daf3e91a76c1c43764c638aaf3966785_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/daf3e91a76c1c43764c638aaf3966785_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d61c1fbf4b02f8ccfd38d9a1f34f596b566daa59 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/daf3e91a76c1c43764c638aaf3966785_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2c086eac0061b9ec6dd71d8620ee4b45d7137171a0e86a709218c7daf3a0054f +size 57321 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/dc21ed4c0501e22f20e9c9eb4475cf78_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/dc21ed4c0501e22f20e9c9eb4475cf78_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3e877db0aa89007fa4933d8c395aff8f6e74be4 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/dc21ed4c0501e22f20e9c9eb4475cf78_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e09238c1385e6961baab01ca8e6188e504b8ca438bbfab5b33fcbad7d5261b11 +size 52471 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/e4056ca9b553db5c2dd45c38119bddb8_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/e4056ca9b553db5c2dd45c38119bddb8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e8bcf76bc199b44f1d853eaccc83d680d0a82424 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/e4056ca9b553db5c2dd45c38119bddb8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:eba12725921b297b0975887c826e89ea4db6ba65ebfebadacbc350e22416dd29 +size 51982 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/f430d2974ad0817ea0d03da54f740fad_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/f430d2974ad0817ea0d03da54f740fad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9aaed531b0526344f4561d14f0ace055f32ef1b3 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/f430d2974ad0817ea0d03da54f740fad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1ea7ca8f2df32eee7246b6376fadbb2f9cebd4a0c3108b88a6cf2a6a25e101bb +size 50881 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/fba6bf9826da19a2daa3bf12bb3d9c08_img.jpg b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/fba6bf9826da19a2daa3bf12bb3d9c08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a924a948e0b0cbb620672fa1eeaf472c5feb09e8 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/fba6bf9826da19a2daa3bf12bb3d9c08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:26161248e5cd47d092ede7dbb3a392b537d02668477c66ecc4150117baf988bb +size 4027 diff --git a/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/raw.md b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..aa6ea64e84f7e62eb16321dd9df8e4c5873f3186 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.O1-Interface.0-v04.00/raw.md @@ -0,0 +1,2593 @@ + + +# O-RAN Operations and Maintenance Interface Specification --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Operations and Maintenance Interface Specification** --- + +Copyright © 2021 by the O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +# Revision History + +| Date | Revision | Author | Description | +|------------|------------|------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2019.03.18 | 0.01.00.00 | David Kinsey (AT&T) Li Xiang(CMCC), Cagatay Buyukkoc (AT&T), Lyndon Ong (Ciena), Marge Hillis (Nokia) and Linda Horn (Nokia) | First draft of O-RAN OAM Interface Specification | +| 2019.03.28 | 0.01.01.00 | Marge Hillis (Nokia) | Updates from review remarks received | +| 2019.05.21 | 0.01.01.01 | Marge Hillis (Nokia) | Fault Supervision, Performance Assurance and File Management updates | +| 2019.05.28 | 0.01.01.02 | Marge Hillis, Linda Horn (Nokia) | References, Abbreviations, Definitions, Provisioning, Communication Surveillance, PNF Start Up and Registration updates | +| 2019.06.13 | 0.01.01.03 | Marge Hillis, Linda Horn (Nokia), David Kinsey (ATT) | Diagrams for File Management converted to UML, Performance Assurance UML, PNF Software Management Updates | +| 2019.06.17 | 0.01.01.04 | Marge Hillis, Linda Horn | Provisioning Updates | +| 2019.07.01 | 01.00 | Marge Hillis, Linda Horn | Review Comments Addressed TSC approved copy | +| 2019.09.27 | 02.00 | Marge Hillis, Linda Horn | Updates for late review comments, additional CM notifications, NETCONF requirements and updated references to 3GPP SA5 Rel-16. | +| 2020.03.03 | 03.00 | Marge Hillis, Linda Horn | Update Heartbeat Management Service. New Sections for Subscription Control, Streaming PM, O-RAN Defined PM Measurements and an Annex showing examples for using the specified template for O-RAN defined PM Measurements. | +| 2020.08.18 | 04.00 | Marge Hillis, Linda Horn, Louise Sun | Update Introductory Material, Provisioning, Fault Supervision, Performance Assurance, Trace Management, and Heartbeat Management to incorporate 3GPP Rel 16 CRs. Add Annex B for stdDefined event example and Annex C for Streaming Trace example. | +| 2020.08.31 | 04.00 | Marge Hillis, Linda Horn | Update document with comments from WG1 review | + +# Contents + +| | | +|--------------------------------------------------------------------------|----| +| Revision History ..... | 2 | +| Chapter 1.       Introductory Material ..... | 5 | +| 1.1       Scope ..... | 5 | +| 1.2       References ..... | 5 | +| 1.3       Definitions and Abbreviations ..... | 7 | +| 1.3.1       Definitions ..... | 7 | +| 1.3.2       Abbreviations ..... | 7 | +| 1.4       Philosophy ..... | 9 | +| 1.5       Open Points ..... | 9 | +| 1.6       General Requirements ..... | 9 | +| 1.6.1       Service Management and Orchestration (SMO) ..... | 9 | +| 1.6.2       Transport Layer Security (TLS) ..... | 9 | +| 1.6.3       HyperText Transfer Protocol (HTTP) ..... | 9 | +| Chapter 2.       Management Services ..... | 11 | +| 2.1       Provisioning Management Services ..... | 11 | +| 2.1.1       General NETCONF Requirements ..... | 11 | +| 2.1.2       Create Managed Object Instance ..... | 12 | +| 2.1.3       Modify Managed Object Instance Attributes ..... | 14 | +| 2.1.4       Delete Managed Object Instance ..... | 16 | +| 2.1.5       Read Managed Object Instance Attributes ..... | 18 | +| 2.1.6       Notify Managed Object Instance Attribute Value Changes ..... | 19 | +| 2.1.7       Notify Managed Object Instance Creation ..... | 20 | +| 2.1.8       Notify Managed Object Instance Deletion ..... | 21 | +| 2.1.9       Notify Managed Object Instance Changes ..... | 22 | +| 2.1.10       Subscription Control ..... | 23 | +| 2.2       Fault Supervision Management Services ..... | 24 | +| 2.2.1       Fault Notification ..... | 24 | +| 2.2.2       Fault Supervision Control ..... | 26 | +| 2.3       Performance Assurance Management Services ..... | 26 | +| 2.3.1       Performance Data File Reporting ..... | 27 | +| 2.3.2       Performance Data Streaming ..... | 28 | +| 2.3.3       Measurement Job Control ..... | 30 | +| 2.3.4       O-RAN Defined Performance Measurements ..... | 31 | +| 2.4       Trace Management Services ..... | 31 | +| 2.4.1       Call Trace ..... | 32 | +| 2.4.2       Minimization of Drive Testing (MDT) ..... | 34 | +| 2.4.3       Radio Link Failure (RLF) ..... | 35 | +| 2.4.4       RRC Connection Establishment Failure (RCEF) ..... | 35 | +| 2.4.5       Trace Control ..... | 36 | +| 2.4.6       Streaming Trace ..... | 36 | +| 2.5       File Management Services ..... | 37 | +| 2.5.1       File Ready Notification ..... | 37 | +| 2.5.2       List Available Files ..... | 38 | +| 2.5.3       File Transfer by File Management MnS Consumer ..... | 39 | +| 2.5.4       Download File ..... | 41 | +| 2.6       Heartbeat Management Services ..... | 42 | +| 2.6.1       Heartbeat Notification ..... | 42 | +| 2.6.2       Heartbeat Control ..... | 43 | +| 2.7       PNF Startup and Registration Management Services ..... | 44 | +| 2.7.1       PNF Plug-n-Play ..... | 44 | +| 2.7.2       PNF Registration ..... | 44 | +| 2.8       PNF Software Management Services ..... | 45 | +| 2.8.1       Software Package Naming and Content ..... | 45 | + +| | | | +|-------------------------------------------------------------------------------|-------------------------------------|----| +| 2.8.2 | Software Inventory ..... | 46 | +| 2.8.3 | Software Download ..... | 47 | +| 2.8.4 | Software Activation Pre-Check ..... | 49 | +| 2.8.5 | Software Activate ..... | 50 | +| Annex A: (Informative) O-RAN Performance Measurement Definition Example ..... | | 55 | +| Annex B: (Informative) Guidelines and Example for stdDefined VES Events ..... | | 57 | +| Annex C: (Informative) Streaming Trace Management Activation Example ..... | | 60 | +| Annex ZZZ: O-RAN Adopter License Agreement ..... | | 63 | + +# Chapter 1. Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG1 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit is included only in working versions of the document indicating incremental changes during the editing process. + +This document defines O-RAN OAM interface functions and protocols for the O-RAN O1 interface. The document studies the functions conveyed over the interface, including management functions, procedures, operations and corresponding solutions, and identifies existing standards and industry work that can serve as a basis for O-RAN work. + +This document will follow the requirements specification language defined in IETF RFC 2119 [32] updated by RFC 8174 [36]. For consistency requirements are specified using “SHALL” to indicate that the implementation is required. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 16. + +- [1] 3GPP TR 21.905: Vocabulary for 3GPP Specifications (Release 16), v16.0.0, 2019-06 +- [2] 3GPP TS 28.530: Management and orchestration; Concepts, use cases and requirements (Release 16), v16.2.0, 2020-07 +- [3] 3GPP TS 28.531: Management and orchestration; Provisioning (Release 16), v16.6.0, 2020-07 +- [4] 3GPP TS 28.532: Management and orchestration; Generic management services (Release 16), v16.4.0, 2020-06 +- [5] 3GPP TS 28.533: Management and orchestration: Architecture framework (Release 16), v16.4.0, 2020-06 +- [6] 3GPP TS 28.537: Management and orchestration; Management capabilities (Release 16), v16.0.0, 2020-03 +- [7] 3GPP TS 28.540: Management and orchestration; 5G Network Resource Model (NRM); Stage 1 (Release 16), v16.1.0, 2019-12 +- [8] 3GPP TS 28.541: Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3 (Release 16), v16.5.0, 2020-06 +- [9] 3GPP TS 28.545: Management and orchestration; Fault Supervision (FS) (Release 16), v16.0.0, 2020-07 +- [10] 3GPP TS 28.550: Management and orchestration; Performance assurance (Release 16), v16.5.0, 2020-07 + +- [11] 3GPP TS 28.552: Management and orchestration; 5G performance measurements (Release 16), v16.6.0, 2020-07 +- [12] 3GPP TS 28.554: Management and orchestration; 5G end to end Key Performance Indicators (KPI) (Release 16), v16.5.0, 2020-07 +- [13] 3GPP TS 28.621: Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Requirements (Release 16), v16.0.0, 2020-07 +- [14] 3GPP TS 28.622: Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS) (Release 16), v16.4.0, 2020-07 +- [15] 3GPP TS 28.623: Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Solution Set (SS) definitions (Release 16), v16.4.0, 2020-07 +- [16] 3GPP TS 32.111-2: Telecommunication management; Fault Management; Part 2: Alarm Integration Reference Point (IRP): Information Service (IS) (Release 16), v16.0.0, 2020-07 +- [17] 3GPP TS 32.341: Telecommunication management; File Transfer (FT) Integration Reference Point (IRP); Requirements (Release 16), v16.0.0, 2020-07 +- [18] 3GPP TS 32.342: Telecommunication management; File Transfer (FT) Integration Reference Point (IRP); Information Service (IS) (Release 16), v16.0.0, 2020-07 +- [19] 3GPP TS 32.346: Telecommunication management; File Transfer (FT) Integration Reference Point (IRP): Solution Set (SS) definitions (Release 16), v16.0.0, 2020-07 +- [20] 3GPP TS 32.404: Telecommunication management; Performance Management (PM); Performance Measurements; Definitions and template (Release 16), v16.0.0, 2020-07 +- [21] 3GPP TS 32.421: Telecommunication management; Subscriber and equipment trace; Trace concepts and requirements (Release 16), v16.1.0, 2020-03 +- [22] 3GPP TS 32.422: Telecommunication management; Subscriber and equipment trace; Trace control and configuration management (Release 16), v16.2.0, 2020-07 +- [23] 3GPP TS 32.423: Telecommunication management; Subscriber and equipment trace; Trace data definition and management (Release 16), v16.1.0, 2020-07 +- [24] 3GPP TS 32.508: Telecommunication management; Procedure flows for multi-vendor plug-and-play eNode B connection to the network (Release 16), v16.0.0, 2020-07 +- [25] 3GPP TS 32.509: Telecommunication management; Data formats for multi-vendor plug and play eNode B connection to the network (Release 16), v16.0.0, 2020-07 +- [26] 3GPP TS 37.320: Universal Terrestrial Radio Access (UTRA), Evolved Universal Terrestrial Radio Access (E-UTRA) and Next Generation Radio Access; Radio measurement collection for Minimization of Drive Tests (MDT); Overall description; Stage 2 (Release 16), v16.0.0, 2020-03 +- [27] O-RAN WG1: O-RAN Use Cases and Deployment Scenarios WhitePaper, February 2020 +- [28] O-RAN WG1: O-RAN Architecture Description, v1.0, February 2020 +- [29] O-RAN WG1: O-RAN Operations and Maintenance Architecture, v3.0, April 2020 +- [30] O-RAN WG4: O-RAN Fronthaul Management Plane Specification, v3.0, April 2020 +- [31] ONAP VES Event Listener Specification v7.2, May 2020 (Draft) +- [32] RFC 2119, “Key words for use in RFCs to Indicate Requirement Levels”, IETF, March 1997 +- [33] RFC 6241, “Network Configuration Protocol (NETCONF)”, IETF, June 2011 +- [34] RFC 7950, “The YANG 1.1 Data Modeling Language”, IETF, August 2016 +- [35] RFC 7951, “JSON Encoding of Data Modeled with YANG”, IETF, August 2016 +- [36] RFC 8174, “Ambiguity of Uppercase vs Lowercase in RFC 2119 Key Words”, IETF, May 2017 + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [1]. + +Harmonized VES Event refers to the stdDefined VES event specified in VES Event Listener Specification [31] that allows a VES event to carry, as its payload, a notification specified by another standards body. In the case of O-RAN O1 Interface Specification, a harmonized stdDefined VES event carries a 3GPP-specified notification as its payload. + +Legacy VES Event refers to any VES event specified in the VES Event Listener Specification [31], except for stdDefined. Legacy VES events are fully defined in [31] and don't rely on another standards organization to specify the content of the payload, like stdDefined does. Examples of Legacy VES Events are Fault, Heartbeat and FileReady Notification. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [1]. + +| | | +|-------|---------------------------------------------------------| +| 3GPP | 3 rd Generation Partnership Project | +| ASN.1 | Abstract Syntax Notation One | +| CM | Configuration Management | +| CRUD | Create, Read, Update, Delete | +| EMS | Element Management System | +| FCAPS | Fault, Configuration, Accounting, Performance, Security | +| FG | Focus Group | +| FM | Fault Management | +| FS | Fault Supervision | +| FTPES | File Transfer Protocol with Explicit SSL/TLS encryption | +| GPB | Google Protocol Buffers | +| HTTP | HyperText Transfer Protocol | +| HTTPS | HTTP Secure | +| ID | IDentifier | +| IETF | Internet Engineering Task Force | +| IOC | Information Object Class | +| IP | Internet Protocol | +| JSON | JavaScript Object Notation | +| MANO | Management and Orchestration | +| MDT | Minimization of Drive Testing | +| ME | Managed Element | +| MF | Managed Function | +| MnS | Management Service | +| MO | Managed Object | +| MOC | Managed Object Class | + +| | | | +|-----|-------------|--------------------------------------------------------------| +| 126 | MOI | Managed Object Instance | +| 127 | NAT | Network Address Translation | +| 128 | Near-RT RIC | O-RAN Near Real Time RAN Intelligent Controller | +| 129 | NETCONF | NETwork CONFiguration protocol | +| 130 | NF | Network Function | +| 131 | NGRAN | Next Generation Radio Access Network | +| 132 | NMS | Network Management System | +| 133 | Non-RT RIC | O-RAN Non Real Time RAN Intelligent Controller | +| 134 | NR | New Radio | +| 135 | NRM | Network Resource Model | +| 136 | O-CU-CP | O-RAN Central Unit – Control Plane. | +| 137 | O-CU-UP | O-RAN Central Unit – User Plane | +| 138 | O-DU | O-RAN Distributed Unit | +| 139 | O-RAN | Open Radio Access Network | +| 140 | O-RU | O-RAN Radio Unit | +| 141 | ONAP | Open Network Automation Platform | +| 142 | OSM | Open Source Mano | +| 143 | PM | Performance Management or Performance Measurements | +| 144 | PNF | Physical Network FunctionRAN Radio Access Network | +| 145 | RCEF | RRC Connection Establishment Failure | +| 146 | RRH | Remote Radio Head | +| 147 | REST | REpresentational State Transfer | +| 148 | RFC | Request For Comments | +| 149 | RLF | Radio Link Failure | +| 150 | RRC | Radio Resource Control | +| 151 | SA5 | Services & System Aspects Working Group 5 Telecom Management | +| 152 | SBMA | Services Based Management Architecture | +| 153 | SMO | Service Management and Orchestration | +| 154 | SFTP | SSH File Transfer Protocol | +| 155 | SSH | Secure Shell | +| 156 | STG | Security Task Group | +| 157 | TG | Task Group | +| 158 | TLS | Transport Layer Security | +| 159 | TR | Technical Report | +| 160 | TRS | Trace Recording Session | +| 161 | TS | Technical Specification | +| 162 | UE | User Equipment | +| 163 | URI | Uniform Resource Identifier | +| 164 | VES | VNF Event Stream | +| 165 | VNF | Virtualized Network Function | + +| | | | +|-----|-----|----------------------------| +| 166 | WG | Working Group | +| 167 | WI | Work Item | +| 168 | XML | eXtensible Markup Language | + +169 + +###### 170 1.4 Philosophy + +171 It is expected that O-RAN Managed Elements, specified in O-RAN Operations and Maintenance Architecture [29], +172 comply with the O1 Interface Specification. + +173 The O-RAN O1 management services follow existing standards wherever possible. The focus of this document is to +174 identify the use cases which conform to existing standards, identify gaps in management services for O-RAN and define +175 needed extensions. For identified gaps, the goal is to modify the standards to include the needed O-RAN extensions +176 and update the references in this document as the standards evolve to cover the gaps. If extensions and gaps are not +177 specified, it is expected that the management services providers and consumers are conforming to referenced 3GPP +178 specifications. + +###### 179 1.5 Open Points + +180 As each Management Service is evaluated, the Use Cases and relevant specifications need to be assessed and +181 augmented as needed to support O-RAN. The current list of Use Cases in Chapter 2 below is not exhaustive, and the list +182 of specification references may not be complete. + +183 Some Use Cases referred to in the standard may not be applicable to O-RAN and this needs to be addressed, as an +184 exception. + +185 Future clarifications may be added to specify when citing a reference whether it is being used as a citation (meaning it +186 will be strictly followed) or as a reference. More precise terminology may be included as this draft matures. + +187 O-RAN Security Task Group (STG) plans to develop an O-RAN security architecture, as well as security guidelines +188 and requirements for all O-RAN Working Groups (WG) and O-RAN entities. The security architecture, guidelines and +189 requirements will be incorporated into existing O-RAN documents, as appropriate. The O1 Interface Specification +190 intends to comply with the security architecture, guidelines and requirements that are applicable to the O1 interface and +191 will provide appropriate references, when available. + +192 It is mandatory for the O-RU to comply with the O-RAN Fronthaul Management Plane Specification [30] for +193 management services. There is a joint WG1/WG4 Work Item (WI) in progress to determine how the O-RU can support +194 management services in the O1 Interface Specification, in what time frame, and under what conditions. Future versions +195 of the O1 Interface Specification will be updated as necessary to reflect the decisions of this WI. + +###### 196 1.6 General Requirements + +197 This section contains general requirements that are applicable to many O1 Interface Management Services. + +###### 198 1.6.1 Service Management and Orchestration (SMO) + +199 REQ-SMO-FUN-1: O-RAN compliant SMOs SHALL support the O1 interfaces as defined in this document. + +###### 200 1.6.2 Transport Layer Security (TLS) + +201 REQ-TLS-FUN-1: Management Service providers and consumers that use TLS SHALL support TLS v1.2 or higher. + +###### 202 1.6.3 HyperText Transfer Protocol (HTTP) + +203 REQ-HTP-FUN-1: Management Service providers and consumers that use HTTP SHALL support HTTP v1.1 or +204 higher. HTTP v2.0 is preferred. + + + +# Chapter 2. Management Services + +## 2.1 Provisioning Management Services + +Provisioning management services allow a Provisioning MnS Consumer to configure attributes of managed objects on the Provisioning MnS Provider that modify the Provisioning MnS Provider's capabilities in its role in end-to-end network services and allows a Provisioning MnS Provider to report configuration changes to the Provisioning MnS Consumer. NETCONF is used for the Provisioning Management Services to Create Managed Object Instance, Delete Managed Object Instance, Modify Managed Object Instance Attributes and Read Managed Object Instance Attributes. A REST/HTTPS event is used to notify the Provisioning MnS subscribed Consumers when a configuration change occurs. + +Stage 1 Provisioning management services are specified in 3GPP TS 28.531 [3] section 6.3. + +Stage 2 CM operations and notifications are specified in 3GPP TS 28.532 [4] section 11.1.1. + +Stage 3 Provisioning operations for YANG/NETCONF solution set are specified in 3GPP TS 28.532 [4] section 12.1.3. + +Stage 3 CM notifications for RESTful HTTP-based solution set are specified in 3GPP TS 28.532 [4] section A.1.1. + +IETF reference documents for NETCONF and YANG include RFC 6241, "Network Configuration Protocol (NETCONF)" [33] and RFC 7950, "The YANG 1.1 Data Modeling Language" [34]. + +### 2.1.1 General NETCONF Requirements + +REQ-GNC-FUN-1: The provisioning management service provider and consumer SHALL support the following NETCONF operations as specified in RFC 6241 [33]: + +- get +- get-config +- edit-config +- lock +- unlock +- close-session +- kill-session + +Other operations are optional. + +REQ-GNC-FUN-2: The provisioning management service provider and consumer SHALL support the following NETCONF capabilities: + +- writable-running +- rollback-on-error +- validate +- xpath + +Other capabilities are optional. + +REQ-GNC-FUN-3: The provisioning management service provider and consumer SHALL support a running datastore for NETCONF. Support for a candidate datastore is optional. + +REQ-GNC-FUN-4: The provisioning management service provider and consumer SHALL support YANG1.1, defined in RFC 7950 [34], including coexistence with YANG Version 1 as specified therein. + +- 38 REQ-GNC-FUN-5: The provisioning management service provider SHALL have the capability to establish a +39 NETCONF session with its authorized consumer upon request from the consumer. +- 40 REQ-GNC-FUN-6: The provisioning management service provider SHALL support an established NETCONF session +41 until the authorized consumer terminates the session. NOTE: The consumer may want to perform multiple provisioning +42 management services operations during a single NETCONF Session. +- 43 REQ-GNC-FUN-7: The provisioning management service provider SHALL have the capability to terminate a +44 NETCONF session with its authorized consumer when requested to do so by the authorized consumer. +- 45 REQ-GNC-FUN-8: The provisioning management service provider SHALL have the capability to make provisioning +46 operation results persistent over a reset. +- 47 REQ-GNC-FUN-9: The provisioning management service provider and consumer SHALL support NETCONF over +48 SSH or NETCONF over TLS. + +###### 49 2.1.2 Create Managed Object Instance + +###### 50 2.1.2.1 Description + +- 51 Provisioning MnS Consumer sends a synchronous provisioning update request to the Provisioning MnS Provider to +52 create a Managed Object Instance (MOI) on the Provisioning MnS Provider and set its attribute values. + +###### 53 2.1.2.2 Requirements + +- 54 Requirements are specified in 3GPP TS 28.532 [4] section 12.1.3.1.1 and section 12.1.3.1.2. + +55 + +###### 56 2.1.2.3 Procedures + +![Sequence diagram for Create MOI procedure between Provisioning MnS Consumer and Provisioning MnS Provider.](2710f8dcbd3b68f655fa86aef2ab4a2a_img.jpg) + +**Create MOI** + +``` + +sequenceDiagram + participant Consumer as Provisioning MnS Consumer + participant Provider as Provisioning MnS Provider + + Consumer->>Provider: [1] Establish NETCONF Session + opt [Lock Data Store] + Consumer->>Provider: [2] NETCONF + Provider-->>Consumer: [3] NETCONF or + end + Consumer->>Provider: [4] NETCONF + Provider-->>Consumer: [5] NETCONF or NETCONF + opt [Commit Change (applies if target is candidate)] + Consumer->>Provider: [6] NETCONF + Provider-->>Consumer: [7] NETCONF or NETCONF + end + opt [Unlock Data Store (applies if Data Store was locked)] + Consumer->>Provider: [8] NETCONF + Provider-->>Consumer: [9] NETCONF or NETCONF + end + Consumer->>Provider: [10] Terminate NETCONF Session + +``` + +The diagram illustrates the 'Create MOI' procedure between a Provisioning MnS Consumer and a Provisioning MnS Provider. The process follows these steps: + +- [1] Establish NETCONF Session +- [2] NETCONF (Optional: Lock Data Store) +- [3] NETCONF or +- [4] NETCONF +- [5] NETCONF or NETCONF +- [6] NETCONF (Optional: Commit Change (applies if target is candidate)) +- [7] NETCONF or NETCONF +- [8] NETCONF (Optional: Unlock Data Store (applies if Data Store was locked)) +- [9] NETCONF or NETCONF +- [10] Terminate NETCONF Session + +Additional notes in the diagram include: 'Lock DS' (next to step 2), 'Create MOI' (next to step 4), 'ME commits change to the running data store.' (next to step 6), and 'Unlock DS' (next to step 8). + +Sequence diagram for Create MOI procedure between Provisioning MnS Consumer and Provisioning MnS Provider. + +Figure 2.1.2.3-1 Create MOI + +Pre-Condition: Provisioning MnS Consumer has current state of the target datastore of the Provisioning MnS Provider. + +1. Provisioning MnS Consumer establishes NETCONF session with Provisioning MnS Provider. The NETCONF session has authorized create, read, update, and delete privileges into the identified section of the data store. +2. (Optional) Lock Datastore + - a. Provisioning MnS Consumer sends NETCONF . + - b. Provisioning MnS Provider locks target datastore (running or candidate). +3. Provisioning MnS Provider returns response or the appropriate rpc error code. +4. Create MOI + - a. Provisioning MnS Consumer sends NETCONF . + +- b. Provisioning MnS Provider creates the MOI(s) and sets attribute values in the target datastore (DS) as specified in operation and config. If an error occurs, Provisioning MnS Provider behaves as specified in error-option. + +5. Provisioning MnS Provider returns response or the appropriate rpc error code. + +6. (Optional) Commit change if target was candidate + +- a. Provisioning MnS Consumer sends NETCONF . +- b. Provisioning MnS Provider commits the change to the running DS. + +7. Provisioning MnS Provider returns response or the appropriate rpc error code. + +8. (Optional) Unlock Datastore + +- a. Provisioning MnS Consumer sends NETCONF . +- b. Provisioning MnS Provider unlocks the target DS. + +9. Provisioning MnS Provider returns response or the appropriate rpc error code. + +10. Provisioning MnS Consumer terminates NETCONF session with Provisioning MnS Provider. + +### 2.1.3 Modify Managed Object Instance Attributes + +#### 2.1.3.1 Description + +Provisioning MnS Consumer sends synchronous provisioning updates to the Provisioning MnS Provider to modify the attributes of a MOI on the Provisioning MnS Provider. + +#### 2.1.3.2 Requirements + +Requirements are specified in 3GPP TS 28.532 [4] section 12.1.3.1.1 and section 12.1.3.1.4. + +###### 104 2.1.3.3 Procedures + +![Sequence diagram for Modify MOI Attributes between Provisioning MnS Consumer and Provisioning MnS Provider. The diagram shows a series of steps: 1. Establish NETCONF Session. 2. Optional Lock Data Store (NETCONF ). 3. NETCONF or . 4. NETCONF . 5. NETCONF or . 6. Optional Commit Change (NETCONF ). 7. NETCONF or . 8. Optional Unlock Data Store (NETCONF ). 9. NETCONF or . 10. Terminate NETCONF Session.](765f110eb024d18a875bfed64a97e462_img.jpg) + +**Modify MOI Attributes** + +``` + +sequenceDiagram + participant Consumer as Provisioning MnS Consumer + participant Provider as Provisioning MnS Provider + + Consumer->>Provider: [1] Establish NETCONF Session + Note over Consumer, Provider: opt [Lock Data Store] + Consumer->>Provider: [2] NETCONF + Note right of Provider: Lock DS + Provider-->>Consumer: [3] NETCONF or NETCONF + Note over Consumer, Provider: [4] NETCONF + Note right of Provider: Modify MOI + Provider-->>Consumer: [5] NETCONF or NETCONF + Note over Consumer, Provider: opt [Commit Change (applies if target is candidate)] + Consumer->>Provider: [6] NETCONF + Note right of Provider: ME commits change to the running data store. + Provider-->>Consumer: [7] NETCONF or NETCONF + Note over Consumer, Provider: opt [Unlock Data Store (applies if Data Store was locked)] + Consumer->>Provider: [8] NETCONF + Note right of Provider: Unlock DS + Provider-->>Consumer: [9] NETCONF or NETCONF + Consumer->>Provider: [10] Terminate NETCONF Session + +``` + +Sequence diagram for Modify MOI Attributes between Provisioning MnS Consumer and Provisioning MnS Provider. The diagram shows a series of steps: 1. Establish NETCONF Session. 2. Optional Lock Data Store (NETCONF ). 3. NETCONF or . 4. NETCONF . 5. NETCONF or . 6. Optional Commit Change (NETCONF ). 7. NETCONF or . 8. Optional Unlock Data Store (NETCONF ). 9. NETCONF or . 10. Terminate NETCONF Session. + +Figure 2.1.3.3-1 Modify MOI Attributes + +Pre-Condition: Provisioning MnS Consumer has current state of the target datastore of the Provisioning MnS Provider. + +1. Provisioning MnS Consumer establishes NETCONF session with Provisioning MnS Provider. The NETCONF session has authorized create, read, update, and delete privileges into the identified section of the data store. +2. (Optional) Lock Datastore--Provisioning MnS Consumer sends NETCONF . + +- a. Provisioning MnS Provider locks target datastore (running or candidate). +3. Provisioning MnS Provider returns response or the appropriate rpc error code. +4. Modify MOI Attributes + - a. Provisioning MnS Consumer sends NETCONF . + - b. Provisioning MnS Provider modifies the attributes of the MOI(s) in the target datastore (DS) as specified in operation and config. If an error occurs, Provisioning MnS Provider behaves as specified in error-option. +5. Provisioning MnS Provider returns response or the appropriate rpc error code. +6. (Optional) Commit change if target was candidate + - a. Provisioning MnS Consumer sends NETCONF . + - b. Provisioning MnS Provider commits the change to the running DS. +7. Provisioning MnS Provider returns response or the appropriate rpc error code. +8. (Optional) Unlock Datastore + - a. Provisioning MnS Consumer sends NETCONF . + - b. Provisioning MnS Provider unlocks the target DS. +9. Provisioning MnS Provider returns response or the appropriate rpc error code. +10. Provisioning MnS Consumer terminates NETCONF session with Provisioning MnS Provider. + +### 2.1.4 Delete Managed Object Instance + +#### 2.1.4.1 Description + +Provisioning MnS Consumer sends synchronous provisioning updates to the Provisioning MnS Provider to delete a MOI and its children on the Provisioning MnS Provider. + +#### 2.1.4.2 Requirements + +Requirements are specified in 3GPP TS 28.532 [4] section 12.1.3.1.1 and section 12.1.3.1.5. + +###### 154 2.1.4.3 Procedures + +![Sequence diagram for Delete MOI procedure between Provisioning MnS Consumer and Provisioning MnS Provider.](a88af50a99b0f157e34bf16a31a4cb0a_img.jpg) + +**Delete MOI** + +``` + +sequenceDiagram + participant Consumer as Provisioning MnS Consumer + participant Provider as Provisioning MnS Provider + + Consumer->>Provider: [1] Establish NETCONF Session + opt [Lock Data Store] + Consumer->>Provider: [2] NETCONF + Provider->>Provider: Lock DS + Provider-->>Consumer: [3] NETCONF or NETCONF + end + Consumer->>Provider: [4] NETCONF + Provider->>Provider: Delete MOI + Provider-->>Consumer: [5] NETCONF or NETCONF + opt [Commit Change (applies if target is candidate)] + Consumer->>Provider: [6] NETCONF + Provider->>Provider: ME commits change to the running data store. + Provider-->>Consumer: [7] NETCONF or NETCONF + end + opt [Unlock Data Store (applies if Data Store was locked)] + Consumer->>Provider: [8] NETCONF + Provider->>Provider: Unlock DS + Provider-->>Consumer: [9] NETCONF or NETCONF + end + Consumer->>Provider: [10] Terminate NETCONF Session + +``` + +The diagram illustrates the 'Delete MOI' procedure between a Provisioning MnS Consumer and a Provisioning MnS Provider. The process follows these steps: + +- [1] Establish NETCONF Session +- [opt] [Lock Data Store]**: The Consumer sends a NETCONF message. The Provider performs a 'Lock DS' action and returns a NETCONF or a NETCONF message. +- [4] The Consumer sends a NETCONF message. The Provider performs a 'Delete MOI' action. +- [5] The Provider returns a NETCONF or a NETCONF message. +- [opt] [Commit Change (applies if target is candidate)]**: The Consumer sends a NETCONF message. The Provider performs a 'ME commits change to the running data store.' action and returns a NETCONF or a NETCONF message. +- [opt] [Unlock Data Store (applies if Data Store was locked)]**: The Consumer sends a NETCONF message. The Provider performs an 'Unlock DS' action and returns a NETCONF or a NETCONF message. +- [10] Terminate NETCONF Session + +Sequence diagram for Delete MOI procedure between Provisioning MnS Consumer and Provisioning MnS Provider. + +Figure 2.1.4.3-1 Delete MOI + +Pre-Condition: Provisioning MnS Consumer has current state of the target datastore of the Provisioning MnS Provider. + +1. Provisioning MnS Consumer establishes NETCONF session with Provisioning MnS Provider. The NETCONF session has authorized create, read, update, and delete privileges into the identified section of the data store. +2. (Optional) Lock Datastore + - a. Provisioning MnS Consumer sends NETCONF . + - b. Provisioning MnS Provider locks target datastore (running or candidate). +3. Provisioning MnS Provider returns response or the appropriate rpc error code. + +4. Delete MOI and its Children + - a. Provisioning MnS Consumer sends NETCONF . + - b. Provisioning MnS Provider deletes the MOI(s) and its children in the target datastore (DS) as specified in operation and config. If an error occurs, Provisioning MnS Provider behaves as specified in error-option. +5. Provisioning MnS Provider returns response or the appropriate rpc error code. +6. (Optional) Commit change if target was candidate + - a. Provisioning MnS Consumer sends NETCONF . + - b. Provisioning MnS Provider commits the change to the running DS. +7. Provisioning MnS Provider returns response or the appropriate rpc error code. +8. (Optional) Unlock Datastore + - a. Provisioning MnS Consumer sends NETCONF .. + - b. Provisioning MnS Provider unlocks the target DS. +9. Provisioning MnS Provider returns response or the appropriate rpc error code. +10. Provisioning MnS Consumer terminates NETCONF session with Provisioning MnS Provider. + +### 2.1.5 Read Managed Object Instance Attributes + +#### 2.1.5.1 Description + +Provisioning MnS Consumer sends synchronous provisioning request to the Provisioning MnS Provider to return the values of attributes of its MOI(s) on the Provisioning MnS Provider. + +#### 2.1.5.2 Requirements + +Requirements are specified in 3GPP TS 28.532 [4] section section 12.1.3.1.1 and 12.1.3.1.3. + +#### 2.1.5.3 Procedures + +![Sequence diagram for Read MOI Attributes procedure. It shows a Provisioning MnS Consumer and a Provisioning MnS Provider. The consumer sends a NETCONF session establishment request, followed by a NETCONF or request. The provider responds with a NETCONF message. Finally, the consumer sends a NETCONF session termination request. A note on the provider side indicates 'Retrieve config'.](a4b2fdcb199a60adc33b3c99192f2028_img.jpg) + +**Read MOI Attributes** + +``` + +sequenceDiagram + participant Consumer as Provisioning MnS Consumer + participant Provider as Provisioning MnS Provider + Note over Consumer, Provider: [1] Establish NETCONF Session + Consumer->>Provider: [2] NETCONF , or NETCONF + Note right of Provider: Retrieve config + Provider-->>Consumer: [3] NETCONF + Consumer->>Provider: [4] Terminate NETCONF Session + +``` + +Sequence diagram for Read MOI Attributes procedure. It shows a Provisioning MnS Consumer and a Provisioning MnS Provider. The consumer sends a NETCONF session establishment request, followed by a NETCONF or request. The provider responds with a NETCONF message. Finally, the consumer sends a NETCONF session termination request. A note on the provider side indicates 'Retrieve config'. + +**Figure 2.1.5.3-1 Read MOI Attributes** + +1. Provisioning MnS Consumer establishes NETCONF session with Provisioning MnS Provider. +2. Read MOI Attributes + - a. Provisioning MnS Consumer sends NETCONF to retrieve an optionally filtered subset configuration from the source configuration datastore (running or candidate). filter can be used to identify the MOIs and attributes to be returned. + - OR + - Provisioning MnS Consumer sends NETCONF NETCONF to retrieve an optionally filtered subset configuration and operational state of MOIs from the running configuration datastore. filter can be used to identify the MOIs and attributes to be returned. + - b. Provisioning MnS Provider retrieves the requested config from the specified DS. +3. Provisioning MnS Provider returns status in NETCONF response. +4. Provisioning MnS Consumer terminates NETCONF session with Provisioning MnS Provider. + +### 2.1.6 Notify Managed Object Instance Attribute Value Changes + +#### 2.1.6.1 Description + +Provisioning MnS Provider sends an asynchronous notifyMOIAttributeValueChanges Notification to the Provisioning MnS Consumer to report attribute changes to one MOI on the Provisioning MnS Provider. + +#### 2.1.6.2 Requirements + +Requirements are specified in 3GPP TS 28.532 [4] section 11.1.1.9. + +#### 2.1.6.3 Procedures + +![Sequence diagram showing the notification process from Provisioning MnS Provider to Provisioning MnS Consumer.](dc21ed4c0501e22f20e9c9eb4475cf78_img.jpg) + +**Notify Managed Object Instance Attribute Value Changes** + +``` + +sequenceDiagram + participant PMSConsumer as Provisioning MnS Consumer + participant PMSProvider as Provisioning MnS Provider + Note right of PMSProvider: Config change occurs + PMSProvider->>PMSConsumer: 1 <> notifyMOIAttributeValueChanges Notification + Note left of PMSConsumer: Reconcile Database + +``` + +The diagram illustrates the procedure for notifying attribute value changes. It shows two main entities: Provisioning MnS Consumer and Provisioning MnS Provider. On the right side, there are two instances of the Provisioning MnS Provider. The top instance has a note 'Config change occurs'. A message arrow labeled '1 <> notifyMOIAttributeValueChanges Notification' points from the top Provisioning MnS Provider to the Provisioning MnS Consumer. On the left side, there are two instances of the Provisioning MnS Consumer. The bottom instance has a note 'Reconcile Database'. + +Sequence diagram showing the notification process from Provisioning MnS Provider to Provisioning MnS Consumer. + +###### Figure 2.1.6.3-1 Notify Managed Object Instance Attribute Value Changes + +Pre-conditions: (1) One or more attributes of a MOI have changed in the running data store of the Provisioning MnS Provider. (2) Provisioning MnS Consumer has subscribed for notifyMOIAttributeValueChanges notifications. + +1. Provisioning MnS Provider sends notifyMOIAttributeValueChanges notification to the Provisioning MnS Consumer over HTTP/TLS. Mutual certificate authentication is performed. + +Post-condition: Provisioning MnS Consumer reconciles its copy of the Provisioning MnS Provider configuration database with the change. + +#### 2.1.6.4 Operations and Notifications + +See section 2.1.9.4. + +### 2.1.7 Notify Managed Object Instance Creation + +#### 2.1.7.1 Description + +Provisioning MnS Provider sends an asynchronous notifyMOICreation Notification to the Provisioning MnS Consumer to report the creation of one MOI on the Provisioning MnS Provider. + +#### 2.1.7.2 Requirements + +Requirements are specified in 3GPP TS 28.532 [4] section 11.1.1.7. + +#### 2.1.7.3 Procedures + +![Sequence diagram for Notify Managed Object Instance Creation. It shows two parallel vertical flows. The left flow starts with 'Provisioning MnS Consumer' at the top, followed by a dashed line down to 'Reconcile Database' (in a note box), and then a solid line down to 'Provisioning MnS Consumer' at the bottom. The right flow starts with 'Provisioning MnS Provider' at the top, followed by a dashed line down to 'Managed Object Instance Created' (in a note box), and then a solid line down to 'Provisioning MnS Provider' at the bottom. A horizontal arrow points from the right flow to the left flow, labeled '1 <> notifyMOICreation Event'.](9d18912fa12655384ea0a05c76dc9e1d_img.jpg) + +**Notify Managed Object Instance Creation** + +``` + +sequenceDiagram + participant PMSConsumer as Provisioning MnS Consumer + participant PMSProvider as Provisioning MnS Provider + Note over PMSConsumer: Reconcile Database + Note over PMSProvider: Managed Object Instance Created + PMSProvider->>PMSConsumer: 1 <> notifyMOICreation Event + +``` + +Sequence diagram for Notify Managed Object Instance Creation. It shows two parallel vertical flows. The left flow starts with 'Provisioning MnS Consumer' at the top, followed by a dashed line down to 'Reconcile Database' (in a note box), and then a solid line down to 'Provisioning MnS Consumer' at the bottom. The right flow starts with 'Provisioning MnS Provider' at the top, followed by a dashed line down to 'Managed Object Instance Created' (in a note box), and then a solid line down to 'Provisioning MnS Provider' at the bottom. A horizontal arrow points from the right flow to the left flow, labeled '1 <> notifyMOICreation Event'. + +**Figure 2.1.7.3-1 Notify Managed Object Instance Creation** + +Pre-conditions: (1) A MOI is created on the running data store of the Provisioning MnS Provider. (2) Provisioning MnS Consumer has subscribed for notifyMOICreation notifications. + +1. Provisioning MnS Provider sends notifyMOICreation notification to the Provisioning MnS Consumer over HTTP/TLS. Mutual certificate authentication is performed. + +Post-condition: Provisioning MnS Consumer reconciles its copy of the Provisioning MnS Provider configuration database with the change. + +#### 2.1.7.4 Operations and Notifications + +See 2.1.9.4. + +### 2.1.8 Notify Managed Object Instance Deletion + +#### 2.1.8.1 Description + +Provisioning MnS Provider sends an asynchronous notifyMOIDeletion Notification to the Provisioning MnS Consumer to report the deletion of one MOI on the Provisioning MnS Provider. + +#### 2.1.8.2 Requirements + +Requirements are specified in 3GPP TS 28.532 [4] section 11.1.1.8. + +#### 2.1.8.3 Procedures + +![Sequence diagram showing the Notify Managed Object Instance Deletion procedure. The Provisioning MnS Provider sends a notifyMOIDeletion Event to the Provisioning MnS Consumer via HTTP/TLS. The Provisioning MnS Consumer then reconciles its database.](f430d2974ad0817ea0d03da54f740fad_img.jpg) + +**Notify Managed Object Instance Deletion** + +``` + +sequenceDiagram + participant PMnS_P as Provisioning MnS Provider + participant PMnS_C as Provisioning MnS Consumer + PMnS_P->>PMnS_C: 1 <> notifyMOIDeletion Event + PMnS_C->>PMnS_C: Reconcile Database + +``` + +Sequence diagram showing the Notify Managed Object Instance Deletion procedure. The Provisioning MnS Provider sends a notifyMOIDeletion Event to the Provisioning MnS Consumer via HTTP/TLS. The Provisioning MnS Consumer then reconciles its database. + +**Figure 2.1.8.3-1 Notify Managed Object Instance Deletion** + +Pre-conditions: (1) A MOI is deleted from the running data store of the Provisioning MnS Provider. (2) Provisioning MnS Consumer has subscribed for notifyMOIDeletion notifications. + +1. Provisioning MnS Provider sends notifyMOIDeletion notification to the Provisioning MnS Consumer over HTTP/TLS. Mutual certificate authentication is performed. + +Post-condition: Provisioning MnS Consumer reconciles its copy of the Provisioning MnS Provider configuration database with the change. + +#### 2.1.8.4 Operations and Notifications + +See section 2.1.9.4. + +### 2.1.9 Notify Managed Object Instance Changes + +#### 2.1.9.1 Description + +Provisioning MnS Provider sends an asynchronous notifyMOIChanges Notification to the Provisioning MnS Consumer to report configuration changes to one or more MOIs on the Provisioning MnS Provider. + +#### 2.1.9.2 Requirements + +Requirements are specified in 3GPP TS 28.532 [4] section 11.1.1.11. + +#### 2.1.9.3 Procedures + +![Sequence diagram showing the notification process from Provisioning MnS Provider to Provisioning MnS Consumer, including a database reconciliation step.](e4056ca9b553db5c2dd45c38119bddb8_img.jpg) + +**Notify Managed Object Instance Changes** + +``` + +sequenceDiagram + participant PMnS_C as Provisioning MnS Consumer + participant PMnS_P as Provisioning MnS Provider + Note over PMnS_P: One or more config changes occur + PMnS_P->>PMnS_C: 1 <> notifyMOIChanges Notification + Note over PMnS_C: Reconcile Database + +``` + +The diagram illustrates the procedure for notifying managed object instance changes. It shows two main entities: Provisioning MnS Consumer and Provisioning MnS Provider. The process begins with the Provisioning MnS Provider sending a '1 <> notifyMOIChanges Notification' to the Provisioning MnS Consumer. Following this notification, the Provisioning MnS Consumer performs a 'Reconcile Database' action. A note on the Provisioning MnS Provider side indicates that 'One or more config changes occur' before the notification is sent. + +Sequence diagram showing the notification process from Provisioning MnS Provider to Provisioning MnS Consumer, including a database reconciliation step. + +**Figure 2.1.9.3-1 Notify Managed Object Instance Changes** + +Pre-conditions: (1) One or more MOIs are created, deleted or modified in the running data store of the Provisioning MnS Provider. (2) Provisioning MnS Consumer has subscribed for notifyMOIChanges notifications. + +1. Provisioning MnS Provider sends notifyMOIChanges notification to the Provisioning MnS Consumer over HTTP/TLS. Mutual certificate authentication is performed. + +Post-condition: Provisioning MnS Consumer reconciles its copy of the Provisioning MnS Provider configuration database with the change. + +#### 2.1.9.4 Operations and Notifications + +An O-RAN CM notification is a JSON encoded asynchronous notification sent from the Provisioning MnS Provider to the Provisioning MnS Consumer using REST/HTTPS. The attribute name value pairs in the CM notifications are provided using YANG 1.1 encoded in JSON format as specified in RFC 7951 [35]. + +The following 3GPP CM notifications specified in 3GPP TS 28.532 [4] are supported in O-RAN: + +- notifyMOIAttributeValueChanges +- notifyMOICreation +- notifyMOIDeletion +- notifyMOIChanges + +A single notifyMOIChanges notification can report one or more MOI creations, MOI deletions and MOI attribute value changes in one notification. The notifyMOIChanges notification can be used instead of notifyMOICreation, notifyMOIDeletion and notifyMOIAttributeValueChanges notifications. For this reason, notifyMOIChanges is recommended to support and notifyMOICreation, notifyMOIDeletion and notifyMOIAttributeValueChanges are optional to support. + +An O-RAN CM notification must be in one of the following formats: + +1. 3GPP format: + - o A 3GPP CM notification as specified in TS 28.532 [4]. +2. VES format: + - o A harmonized stdDefined VES event, consisting of a VES commonEventHeader and stdDefinedFields with a “data” element that contains a 3GPP CM notification, as specified in 3GPP TS 28.532 [4]. The stdDefined VES event is specified in the VES Event Specification [31]. Annex B in this document provides more information about stdDefined VES events. + +Two attributes are used to indicate the notification format: + +1. notifFormatCapabilities indicates whether the provider supports 3GPP format, VES format or both. This attribute is set by the notification provider at the Managed Element level. It is read-only by the notification consumer. +2. notifFormatConfig indicates whether the provider will send the notifications in 3GPP format or VES format. This attribute is set at the Managed Element level. This means all notifications from a provider are sent in the same format. The configuration is not per notification type. If the provider only supports one format, the provider sets the default value for this attribute to the supported format. Otherwise, if the provider supports both formats, the provider sets the default value for this attribute to VES format. In this second case, the consumer may change this value to 3GPP format. If the consumer attempts to set this attribute to a value not supported by the provider, the configuration will be rejected. + +It is not necessary to support legacy VES for CM notifications because there are no legacy VES events defined for CM. + +### 2.1.10 Subscription Control + +#### 2.1.10.1 Description + +Subscription Control allows a MnS Consumer to subscribe to notifications emitted by a MnS Provider. + +Starting with 3GPP Release 16, dedicated operations for Management Services Use Cases will be supported by IOCs with attributes that can be read and/or set using generic provisioning mechanisms. For Subscription Control, the Subscribe and Unsubscribe operations are replaced with a NtfSubscriptionControl IOC as specified in 3GPP TS 28.622 [14]. NtfSubscriptionControl IOC contains attributes that allow a MnS Consumer to set the recipient address for the notifications and identify the scope of notifications desired. Optionally, the types of notifications desired, and notification filtering may also be provided. If filtering of the notifications is supported, only those notifications that match the specified value would be sent. For example, notifyNewAlarm notifications can be filtered to send only those with severity set to major or critical. + +#### 2.1.10.2 Requirements + +NtfSubscriptionControl IOC is specified in 3GPP TS 28.622 [14] section 4.3.22 with attribute definitions in 4.4.1. + +XML, JSON and YANG models for NtfSubscriptionControl are specified in 3GPP TS 28.623 [15] section D.2.6a. + +###### 366 2.1.10.3 Procedures + +367 NtfSubscriptionControl instances may be created and deleted by the system or pre-installed. Optionally, the +368 NtfSubscriptionControl MOIs can be created and deleted and attributes modified using NETCONF/YANG by the +369 management service consumer following the procedures described in this Provisioning MnS section. + +###### 370 2.1.10.4 Operations and Notifications + +371 Subscription Control can be used to subscribe to alarm notifications specified in 3GPP TS 28.622 [14] section 4.4.1 +372 notificationTypes. Subscription Control can be used to subscribe to heartbeat notifications as specified in 3GPP TS +373 28.622 [14] Figure 4.2.1-5; i.e. by creating the HeartbeatControl MOI as a child of the NtfSubscriptionControl MOI. + +###### 374 2.2 Fault Supervision Management Services + +375 Fault supervision management services allow a Fault Supervision MnS Provider to report errors and events to a Fault +376 Supervision MnS Consumer and allows a Fault Supervision MnS Consumer to perform fault supervision operations on +377 the Fault Supervision MnS Provider, such as get alarm list. + +378 Stage 1 Fault Supervision MnS is specified in 3GPP TS 28.545 [9]. + +379 Stage 2 fault notifications are specified in 3GPP TS 28.532 [4]. + +380 Stage 2 AlarmList IOC and AlarmRecord data type are specified in 3GPP TS 28.622 [14]. + +381 Stage 3 Solution Sets for XML, JSON and YANG are specified in 3GPP TS 28.623 [15]. + +###### 382 2.2.1 Fault Notification + +###### 383 2.2.1.1 Description + +384 Fault Supervision MnS Provider sends asynchronous Fault notification event to Fault Supervision MnS Consumer when +385 an alarm occurs, is cleared, or changes severity. + +###### 386 2.2.1.2 Requirements + +387 The following fault supervision data report service requirements specified in 3GPP TS 28.545 [9] Section 5.2.5 are +388 supported in O-RAN: + +- 389 • REQ-FSDR\_NF-FUN-1 for sending alarm notifications +- 390 • REQ-FSDR\_NF-FUN-3 for alarm notification subscription +- 391 • REQ-FSDR\_NF-FUN-4 for alarm notification unsubscription +- 392 • REQ-FSDR\_NF-FUN-6 for reading the alarm list +- 393 • REQ-FSDR\_NF-FUN-8 for reading the alarm list with a filter +- 394 • REQ-FSDR\_NF-FUN-9 for sending changed alarm notifications +- 395 • REQ-FSDR\_NF-FUN-10 for sending cleared alarm notifications +- 396 • REQ-FSDR\_NF-FUN-11 for sending new alarm notifications + +397 + +398 The following requirements from 3GPP TS 28.545 [9] Section 5.2.5 are optional in O-RAN: + +- 399 • REQ-FSDR\_NF-FUN-2 for providing alarms for virtualized resources + +400 **Rationale:** Alarms for virtualized resources are reported over O2 by the O-Cloud. + +- REQ-FSDR\_NF-FUN-5 for filtering the alarm notifications that are reported + +**Rationale:** Filtering of alarm notifications at the NF level is not recommended. SMO should receive all alarm notifications generated by the NF. Filtering is best done at the SMO level. + +- REQ-FSDR\_NF-FUN-7 for maintaining an alarm list for virtualized resources + +**Rationale:** Alarms for virtualized resources are reported over O2 by the O-Cloud. + +#### 2.2.1.3 Procedures + +Procedures are defined in 3GPP TS 28.545 [9] Section 9.1. + +#### 2.2.1.4 Operations and Notifications + +An O-RAN fault notification is a JSON encoded asynchronous notification sent from Fault Supervision MnS Provider to Fault Supervision MnS Consumers using REST/HTTPS. + +The following 3GPP fault notifications specified in TS 28.532 [4] are supported in O-RAN: + +- notifyNewAlarm +- notifyChangedAlarm +- notifyClearedAlarm + +The other 3GPP fault notifications specified in TS 28.532 [4] are optional. Rationale: There are no use cases defined in O-RAN where these other notifications types are sent. If Use Cases are defined which send these notification types, then this O1 Interface Specification will be updated. + +An O-RAN fault notification must be in one of the following formats: + +1. 3GPP format: + - A 3GPP fault notification as specified in TS 28.532 [4]. +2. VES format: + - A harmonized stdDefined VES event, consisting of a VES commonEventHeader and stdDefinedFields with a “data” element that contains a 3GPP fault notification, as specified in TS 28.532 [4]. The stdDefined VES event is specified in the VES Event Listener Specification [31]. Annex B in this document provides more information about stdDefined VES events. + - A legacy fault VES event, consisting of a VES commonEventHeader and faultFields, as specified in the VES Event Listener Specification [31], is also allowed for backward compatibility. However, a stdDefined VES event is the preferred VES format going forward. + +Two attributes are used to indicate the notification format: + +1. notifFormatCapabilities indicates whether the provider supports 3GPP format, VES format or both. This attribute is set by the notification provider at the Managed Element level. It is read-only by the notification consumer. +2. notifFormatConfig indicates whether the provider will send the notifications in 3GPP format or VES format. This attribute is set at the Managed Element level. This means all notifications from a provider are sent in the same format. The configuration is not per notification type. If the provider only supports one format, the provider sets the default value for this attribute to the supported format. Otherwise, if the provider supports both formats, the provider sets the default value for this attribute to VES format. In this second case, the consumer may change this value to 3GPP format. If the consumer attempts to set this attribute to a value not supported by the provider, the configuration will be rejected. + +It is not necessary to have an attribute to indicate whether harmonized VES or legacy VES is sent for VES format because the VES Event Registration artifact provided by the Network Function at onboarding time specifies the schema of the VES event. + +###### 446 2.2.2 Fault Supervision Control + +###### 447 2.2.2.1 Description + +448 Starting with 3GPP Release 16, dedicated operations for Management Services Use Cases will be supported by IOCs +449 with attributes that can be read and/or set using generic provisioning mechanisms. For Fault Supervision, an AlarmList +450 IOC is specified in 3GPP TS 28.622 [14] that represents the capability to store and manage alarm records. There is one +451 AlarmList per Fault Supervision MnS Provider, created by the Provider. The AlarmList contains one AlarmRecord for +452 each active alarm. The AlarmRecords in the AlarmList can be read by the Fault Supervision MnS Consumer, with an +453 optional filter to retrieve selected AlarmRecords based on the value of attributes in the AlarmRecord. For example, +454 Fault Supervision MnS Consumer is able to retrieve only those AlarmRecords with perceivedSeverity = CRITICAL. + +###### 455 2.2.2.2 Requirements + +456 Fault supervision data report service requirements from 3GPP TS 28.545 [9] Section 5.2.5 that are mandatory for an O- +457 RAN Fault Supervision MnS Provider to support are specified in section 2.2.1.2. + +458 The following fault supervision data control service requirements from 3GPP TS 28.545 [9] Section 5.2.6 are optional +459 for the O-RAN Fault Supervision MnS Provider to support: + +- 460 • **REQ-FSDC\_NF-FUN-1** to support alarm acknowledgement. +461 **Rationale:** There is no Use Case that requires a NF to acknowledge an alarm. This operation is best done +462 at the SMO level. If the NF does not support alarm acknowledgement from the MnS Consumer, then the +463 NF must consider cleared alarms as automatically acknowledged so that they may be removed from the +464 AlarmList. +- 465 • **REQ-FSDC\_NF-FUN-2** to support manual alarm clearing. +466 **Rationale:** Manual clearing of alarms is only for ADMC (Automatically Detected, Manually Cleared) +467 alarms. If the NF supports ADMC alarms, then this operation should be supported. Otherwise, it is not +468 required. +- 469 • **REQ-FSDC\_NF-FUN-4** to support acknowledgement state change notifications. +470 **Rationale:** There is no Use Case that requires a NF to acknowledge an alarm. This operation is best done +471 at the SMO level. If the NF supports alarm acknowledgement, then this operation should be supported. +472 Otherwise, it is not required. + +###### 473 2.2.2.3 Procedures + +474 NETCONF protocol and YANG data models are used to get and set the attributes of the AlarmRecords in the AlarmList. +475 Refer to Provisioning management services section for procedures to read MOI attributes and modify MOI attributes +476 using NETCONF. + +###### 477 2.2.2.4 AlarmList IOC Definition + +478 AlarmList IOC definition is specified in TS 28.622 [14] section 4.3.26 and 4.3.27 with attribute definitions in section +479 4.4.1. +480 YANG solution set for AlarmList IOC is provided in TS 28.623 [15] appendix D.2.9. + +###### 481 2.3 Performance Assurance Management Services + +482 Performance Assurance Management Services allow a Performance Assurance MnS Provider to report file-based (bulk) +483 and/or streaming (real time) performance data to a Performance Assurance MnS Consumer and allows a Performance +484 Assurance MnS Consumer to perform performance assurance operations on the Performance Assurance MnS Provider, +485 such as selecting the measurements to be reported and setting the frequency of reporting. + +486 Use cases are specified in 3GPP TS 28.550 [10] Section 5.1. + +487 Stage 2 File Ready notification is specified in 3GPP TS 28.532 [4]. + +Stage 2 PerfMetricJob IOC is specified in 3GPP TS 28.622 [14]. + +Stage 3 Solution Sets for XML, JSON and YANG are specified in 3GPP TS 28.623 [15]. + +Stage 2 and 3 for streaming data reporting service are specified in TS 28.532 [4]. + +### 2.3.1 Performance Data File Reporting + +#### 2.3.1.1 Description + +Performance Assurance MnS Provider sends asynchronous FileReady notification event to Performance Assurance MnS Consumer sent when PM File(s) is ready for upload. The FileReady notification contains information needed to retrieve the file such as filename and the location where the file can be retrieved. + +Performance Assurance MnS Consumer uploads PM File(s) from the location specified in the notifyFileReady notification. + +#### 2.3.1.2 Requirements + +Requirements are specified in 3GPP TS 28.550 [10] section 5.2.2. + +#### 2.3.1.3 Procedures + +Procedure is specified in 3GPP TS 28.550 [10] section 5.1.1.2. + +![Sequence diagram showing the PM Data File Reporting and Upload process. The diagram involves three entities: Performance Assurance MnS Consumer, Performance Assurance MnS Provider, and File Server. The process starts with a note 'New PM data file available' on the MnS Provider. Step 1: MnS Provider sends '<> notifyFileReady Notification' to MnS Consumer. Step 2: MnS Consumer sends '<> Upload File' to the File Server.](3a8ced9dd8e56b154bf4ba860661cd10_img.jpg) + +**PM Data File Reporting and Upload** + +``` + +sequenceDiagram + participant MnS_Consumer as Performance Assurance MnS Consumer + participant MnS_Provider as Performance Assurance MnS Provider + participant File_Server as File Server + + Note over MnS_Provider: New PM data file available + MnS_Provider->>MnS_Consumer: 1 <> notifyFileReady Notification + MnS_Consumer->>File_Server: 2 <> Upload File + +``` + +Sequence diagram showing the PM Data File Reporting and Upload process. The diagram involves three entities: Performance Assurance MnS Consumer, Performance Assurance MnS Provider, and File Server. The process starts with a note 'New PM data file available' on the MnS Provider. Step 1: MnS Provider sends '<> notifyFileReady Notification' to MnS Consumer. Step 2: MnS Consumer sends '<> Upload File' to the File Server. + +**Figure 2.3.1.3-1 PM Data File Reporting and Upload** + +Pre-condition: A new PM data file is available on the Performance Assurance MnS Provider. + +1. Performance Assurance MnS Provider sends FileReady notification to Performance Assurance MnS Consumer over HTTP/TLS. Mutual certificate authentication is performed. +2. Performance Assurance MnS Consumer sets up a secure FTPeS or SFTP connection to the location specified in the notifyFileReady notification and uploads the PM data file(s). SFTP is authenticated with username/password, SSH keys or X.509 certificates. FTPES is authenticated with X.509 certificates. + +#### 2.3.1.4 Operations and Notifications + +An O-RAN file ready notification is a JSON encoded asynchronous notification sent from Performance Assurance MnS Provider to Performance Assurance MnS Consumers using REST/HTTPS + +An O-RAN file ready notification must be in one of the following formats: + +1. 3GPP format: + - o A 3GPP notifyFileReady notification as specified in TS 28.532 [4]. + +###### 2. VES format: + +- A harmonized stdDefined VES event, consisting of a VES commonEventHeader and stdDefinedFields with a “data” element that contains a 3GPP notifyFileReady notification, as specified in TS 28.532 [4]. The stdDefined VES event is specified in the VES Event Specification v7.2 [31]. Annex B in this document provides more information about stdDefined VES events. +- A legacy file ready VES event, consisting of a VES commonEventHeader and notificationFields, as specified in the VES Event Specification v7.2 [31], is also allowed for backward compatibility. However, a stdDefined VES event is the preferred VES format going forward. + +Two attributes are used to indicate the notification format: + +1. notifFormatCapabilities indicates whether the provider supports 3GPP format, VES format or both. This attribute is set by the notification provider at the Managed Element level. It is read-only by the notification consumer. +2. notifFormatConfig indicates whether the provider will send the notifications in 3GPP format or VES format. This attribute is set at the Managed Element level. This means all notifications from a provider are sent in the same format. The configuration is not per notification type. If the provider only supports one format, the provider sets the default value for this attribute to the supported format. Otherwise, if the provider supports both formats, the provider sets the default value for this attribute to VES format. In this second case, the consumer may change this value to 3GPP format. If the consumer attempts to set this attribute to a value not supported by the provider, the configuration will be rejected. + +It is not necessary to have an attribute to indicate whether harmonized VES or legacy VES is sent for VES format because the VES Event Registration artifact provided by the Network Function at onboarding time specifies the schema of the VES event. + +#### 2.3.1.5 PM File Generation and Reporting + +PM file generation and reporting are specified in 3GPP TS 28.532 [4] section 11.3.2.1.1. + +#### 2.3.1.6 PM File Content + +PM file content is specified in 3GPP TS 28.532 [4] section 11.3.2.1.2. + +#### 2.3.1.7 PM File Naming + +PM file naming is specified in 3GPP TS 28.532 [4] section 11.3.2.1.3. + +#### 2.3.1.8 PM File XML Format + +PM file XML format is specified in 3GPP TS 28.532 [4] section 12.3.2. + +#### 2.3.1.9 5G Performance Measurements + +3GPP defined 5G performance measurements are specified in 3GPP TS 28.552 [11]. In addition to the 3GPP-defined measurements, it is possible to have O-RAN defined measurements and vendor supplied measurements. Section 2.3.4 provides requirements for O-RAN defined measurements. O-RAN defined measurements are named with an “OR.” prefix. Vendor supplied measurements are named with a “VS.” prefix. + +### 2.3.2 Performance Data Streaming + +#### 2.3.2.1 Description + +Performance Assurance MnS Provider streams high volume asynchronous streaming performance measurement data to Performance Assurance MnS Consumer at a configurable frequency. A secure WebSocket connection is established between the Performance Assurance Provider and the Performance Assurance Consumer. The connection will support + +the transmission of one or more streams of PM data. Each stream of PM data is configured as a PerfMetricJob (see section 2.3.6 of this document). The provider supplies information about the supported streams to the consumer during the connection establishment. The connection may be established to support one or more streams. Streams can be added or removed from the connection as the PerfMetricJobs are added or deleted. The connectionID that will carry the streaming PM data is provided to the Performance Assurance Provider during the establishment of the WebSocket connection by the Performance Assurance Consumer. + +#### 2.3.2.2 Requirements + +Requirements for Streaming PM are specified in 3GPP TS 28.550 [10] section 5.2.3. + +#### 2.3.2.3 Procedures + +Use Cases are specified in 3GPP TS 28.550 [10] section 5.1.1.3. Procedures are specified in 3GPP TS 28.532 [4] Section 11.5. These procedures are applicable to both Streaming PM and Streaming Trace. + +![Sequence diagram for Performance Data Streaming showing connection establishment and data transmission between Performance Assurance MnS Consumer and Performance Assurance MnS Provider.](d04d5c55ee66b731eb8c5f3d8d3c24cb_img.jpg) + +**Performance Data Streaming** + +``` + +sequenceDiagram + participant Consumer as Performance Assurance MnS Consumer + participant Provider as Performance Assurance MnS Provider + Note right of Provider: Performance Data Streaming Job Configured + Consumer->>Provider: 1 <> establish Streaming Connection + Provider-->>Consumer: 2 <> Connection Established + loop [[while performance job is active]] + Provider->>Consumer: 3 <> report stream data via performance data stream unit + end + +``` + +The diagram illustrates the Performance Data Streaming procedure. It involves two main entities: the Performance Assurance MnS Consumer and the Performance Assurance MnS Provider. The process begins with the provider having a 'Performance Data Streaming Job Configured'. Step 1 shows the consumer sending an '<> establish Streaming Connection' request to the provider. Step 2 shows the provider responding with '<> Connection Established'. A loop labeled '[[while performance job is active]]' contains Step 3, where the provider sends '<> report stream data via performance data stream unit' to the consumer. + +Sequence diagram for Performance Data Streaming showing connection establishment and data transmission between Performance Assurance MnS Consumer and Performance Assurance MnS Provider. + +Figure 2.3.2.3-1 Perf Data Streaming Connection Establishment and Data Transmission + +Pre-condition: Performance Assurance MnS Provider is configured to produce PerfMetricJob to be delivered via streaming PM to the Performance Assurance Consumer. + +1. Performance Assurance MnS Provider requests to establish a WebSocket connection to begin streaming PM data and provides MetaData about the streams that are to be sent on the connection +2. Performance Assurance Consumer accepts the request to upgrade the connection to a WebSocket. +3. Performance Assurance MnS Provider transmits binary encoded data to consumer while performance job is active. + +#### 2.3.2.4 Operations and Notifications + +3GPP TS 28.532 [4] Section 11.5.1 defines the following operations that an O-RAN compliant NF that supports streaming PM must support. These are the same operations listed for streaming trace in Section 2.4.6.1 of this document. They are repeated here, as it is possible that a NF may support different levels of streaming for trace and performance assurance. + +- establishStreamingConnection operation is specified in TS 28.532 [4] Section 11.5.1.1. Establishing the streaming connection is initiated via an HTTPS POST followed by an HTTP GET (upgrade) to establish the WebSocket connection. + +- terminateStreamingConnection operation is specified in TS 28.532 [4] Section 11.5.1.2. This operation is accomplished via a WebSocket Close Frame to tear down the streaming connection when all stream jobs on this connection have been terminated. The delivery of WebSocket Close Frame is provided by the underlying TCP. +- reportStreamData operation is specified in TS 28.532 [4] Section 11.5.1.3. The streamData field contains the streaming PM data which is encoded according to the format defined in TS 28.550 [10] Annex G which provides the ASN.1 definition of the Performance Data Stream Units. The delivery of WebSocket Close Frame is provided by the underlying TCP. + +If the NF supports the capability of sending multiple PM streams across the WebSocket connection, the following operations are required for O-RAN NFs. + +- addStream operation is specified in TS 28.532 Section 11.5.1.4. This operation is used when a new Performance Assurance Stream (PM job started) is added on the Performance Assurance Provider to be delivered to this consumer and the NF supports multiple streams per connection. The addStream operation is accomplished via an HTTP POST. +- deleteStream operation is specified in TS 28.532 [4] Section 11.5.1.5. This operation is used when a Performance Assurance Stream (PM job stopped) is deleted from the connection between the Performance Assurance Provider and the Performance Assurance Consumer. The deleteStream operation is accomplished via an HTTP DELETE. + +The following operations are specified in TS 28.532 [4] Section 11.5.1 but are optional for O-RAN NFs as there is no use case requiring them. + +- getConnectionInfo operation is specified in TS 28.532 [4] Section 11.5.1.6. This operation allows the performance data streaming service provider to get information from the performance data streaming service consumer on the streams active on the connection. There is no use case in O-RAN requiring this operation. +- getStreamInfo operation is specified in TS 28.532 [4] Section 11.5.1.7. This operation allows the performance data streaming service provider to get the information for one or more streams from the streaming consumer (i.e. stream target). There is no use case in O-RAN requiring this operation. + +No notifications have been defined for Performance Data Streaming. + +#### 2.3.2.5 PM Streaming Data Generation and Reporting + +3GPP TS 28.550 [10] Annex C lists all the Performance Data Stream Unit Content Items. Annex C of this document provides a description of the establishment of the WebSocket connection and the subsequent operations that will be provided as part of the data streaming service. The example utilizes the trace service, but the operations around the establishment and tear down of the connection are the same for streaming PM and streaming Trace. The WebSocket connection will remain until all streams configured to be provided between the PA Provider and the PA Consumer have been terminated. + +#### 2.3.2.6 PM Streaming Data Format + +PM streaming data will be delivered in binary format encoded in ASN.1. 3GPP TS 28.550 [10] Annex G provides ASN.1 definition. + +### 2.3.3 Measurement Job Control + +#### 2.3.3.1 Description + +Starting with 3GPP Release 16, dedicated operations for Performance Assurance Control will be supported by IOCs with attributes that can be read and/or set using generic provisioning mechanisms in the Measurement Job Control Service. For Performance Assurance, this includes operations such as Create Measurement Job, Terminate + +636 Measurement Job, Query Measurement Job, Suspend Measurement Job and Resume Measurement Job. Measurement +637 jobs can be created and terminated by creating and deleting a PerfMetricJob MOI. Measurement jobs can be queried by +638 getting the attributes of a PerfMetricJob MOI. Measurement jobs can be temporarily suspended or resumed by +639 modifying the administrativeState attribute of a PerfMetricJob MOI to LOCKED or UNLOCKED. + +###### 640 2.3.3.2 Requirements + +641 Requirements for measurement job control are specified in TS 28.550 [10] section 5.2.1. + +###### 642 2.3.3.3 Procedures + +643 Procedures for measurement job creation, termination, query, suspend and resume are specified in TS 28.622 [14] +644 section 4.3.31. + +645 NETCONF protocol and YANG data models are used to create MOI, delete MOI, modify attributes and get attributes of +646 a PerfMetricJob. Refer to Provisioning management services section for detailed procedures on how to perform these +647 operations using NETCONF. + +###### 648 2.3.3.4 PerfMetricJob IOC Definition + +649 PerfMetricJob IOC definition is specified in TS 28.622 [14] section 4.3.31 with attribute definitions in section 4.4.1. +650 SupportedPerfMetricGroup datatype is specified in TS 28.622 [14] section 4.3.32. ReportingCtrl specified in TS +651 28.622 [14] section 4.3.33. + +652 YANG solution set for PerfMetricJob IOC is provided in TS 28.623 [15] appendix D.2.4. + +###### 653 2.3.4 O-RAN Defined Performance Measurements + +###### 654 2.3.4.1 Requirements + +655 REQ-OPM-FUN-1: O-RAN specific counters shall be defined using the template specified in 3GPP TS 32.404 [20]. + +656 REQ-OPM-FUN-2: The Measurement Name for O-RAN defined counters shall not exceed 64 characters in length and +657 should be constrained to 32 characters maximum. + +658 REQ-OPM-FUN-3: Measurement Name of O-RAN defined counters shall begin with OR.xxx to indicate that O-RAN +659 is the source of the measurement. When a measurement is accepted in 3GPP, the OR prefix shall be deleted. + +660 Annex A provides an example of how two previously defined O-RAN O-RU counters could be re-specified following +661 the template in 3GPP TS 32.404 [20]. PLEASE NOTE, the O1 Interface Specification will not be specifying O-RAN +662 counters. It is the responsibility of the Working Groups to do this specification. This Annex is informational to provide +663 possible examples for defining counters as required in this document. O-RAN defined counters will be documented in +664 the appropriate Working Group specifications. + +###### 665 2.4 Trace Management Services + +666 Trace management services allow a Trace MnS Provider to report file-based or streaming trace records to the Trace +667 MnS Consumer. Trace Control provides the ability for the Trace Consumer to start a trace session by configuring a +668 Trace Job via the Trace Control IOC or by establishing a trace session that will propagate trace parameters to other trace +669 management providers via signaling. There are multiple levels of trace that can be supported on the provider as +670 described in 3GPP TS 32.421 [21] Section 4.1. The Trace Provider may be configured to support file-based trace +671 reporting or streaming trace reporting. + +672 Trace Management Services specified in 3GPP TS 32.421 [21], TS 32.422 [22] and TS 32.423 [23] and supported on an +673 applicable O-RAN ME include Call Trace, Minimization of Drive Testing (MDT), RRC Connection Establishment +674 Failure (RCEF) and Radio Link Failure TCE (RLF). All of these services follow a similar management paradigm. +675 Trace Sessions are configured on the provider with information on where and how to send the trace information to the +676 consumer. The provider creates trace records within a trace session as the trigger mechanism occurs. Trace records are +677 produced and provided to the consumer until the trace session is terminated. + +678 File-based trace collects trace records in files that are available to the consumer with a time delay. In the case of +679 streaming trace, the data is sent in bursts across a WebSocket connection to the consumer, maintaining the relevance of +680 the data while minimizing transport overhead. + +681 Stage 1 Trace Management Service is specified in 3GPP TS 32.421 [21]. Use cases for trace are specified in Section +682 5.8 and elaborated in TS 32.421 [21] Annex A. General Trace Requirements are found in TS 32.421 [21] section 5.1. + +683 Stage 2 Trace Operations are found in TS 32.422 [22] for 5G support of Call Trace and for streaming trace. + +684 Stage 2 Trace Control IOC for management-based control is specified in 3GPP TS 28.622 [14]. Stage 2 for signaling +685 based activation is found in TS 32.422 [22]. + +686 Stage 3 definitions of trace record content for all trace types, XML trace file format, and streaming trace GPB record +687 definition are found in TS 32.423 [23]. + +688 Stage 3 Trace Control IOC mapping for management-based control is found in TS 28.623 [15]. A CR to specify the +689 YANG model for this IOC has been approved in 3GPP SA5 and will be incorporated into a future version of TS 28.623 +690 [15]. + +691 Stage 2 and 3 definition of streaming data reporting are found in TS 28.532 [4]. + +###### 692 2.4.1 Call Trace + +###### 693 2.4.1.1 Trace Data Reporting + +###### 694 2.4.1.1.1 Description + +695 Trace Data can be reported from the Trace Provider to the Trace Consumer via trace files or via a streaming interface. +696 For management-based activation, Trace Data is collected after the TraceJob is configured on the Trace Provider, the +697 Trace Session is activated, and the triggering event occurs. For signaling-based activation, the Trace Recording Session +698 starts when the NF receives trace control and configuration parameters via one of the signalling messages specified in +699 TS 32.422 [22] Section 4.2.3.12. + +700 When the Trace Provider collects trace data to a file, the file is periodically provided to the Trace Consumer. When the +701 provider supports streaming trace, the trace is sent to the consumer via data bursts which are sent frequently enough to +702 retain the relevance of the data while conserving transport resources. The WebSocket connection carrying the streaming +703 trace is preserved for the duration of the streaming trace. + +###### 704 2.4.1.1.2 Requirements + +705 Requirements for Trace data are specified in TS 32.421 [21] Section 5.2 and are applicable to both file-based and +706 streaming trace. + +###### 707 2.4.1.1.3 Procedures + +708 Trace Data is binary encoded and reported in Trace Records. The procedures for reporting data are specified in TS +709 32.422 [22] Section 7. File-based trace reporting procedures are found in TS 32.422 [22] Sections 7.1.1 and 7.2.1. +710 Streaming trace reporting procedures are found in TS 32.422 [22] Sections 7.1.2 and 7.2.2. Trace Record Contents are +711 specified in TS 32.423 [23] Section 4. The Trace Record content is the same for trace jobs controlled by management- +712 based activation and signaling-based activation. The raw trace record content is the same for file-based trace and +713 streaming trace. Trace data is binary encoded in ASN.1. File-based trace is delivered in XML format with trace +714 records encoded in ASN.1. Streaming trace is delivered in GPB encoded data bursts with the trace record payload +715 containing ASN.1 encoded data. + +716 Procedures for naming the trace data file are found in TS 32.423 [23] Annex B. File Naming Convention is fully +717 specified in TS 32.423 [23] Annex B.1. + +718 Trace files are produced in XML format. The XML format is specified in TS 32.423 [23] Annex A2.2. Example XML +719 files are provided in TS 32.423 [23] Annex D. + +If a trace file cannot be created, a trace failure notification file XML schema should be sent. The XML schema is provided in TS 32.422 [22] Annex A5 and the naming convention for the file containing the failure is specified in Annex A4. + +For streaming trace, raw trace data is collected on the node and sent to the trace collector. The trace data will be binary encoded. The format of the streaming trace data is provided in TS 32.423 [23]. The reportStreamData operation is specified in TS 28.532 [4] Section 12.5.1.1.4. + +#### 2.4.1.2 Trace Session Activation + +##### 2.4.1.2.1 Description + +A trace session will start on a provider configured to support a TraceJob via management or signaling-based activation. Management-based trace session activation is initiated from the Provisioning Management Service Consumer to activate a TraceJob which has been configured on the provider. See Section 2.4.5 of this document. With signaling-based trace session activation, the provider receives a signaling message that contains trace consumer ID address (IP address for file-based or URI for streaming) along with trace control parameters. Each Trace session has a unique trace session identifier that is associated with all of the trace data collected for this session. + +If the trace session is configured to be file-based, the provider collects the data and stores the data in a file. The provider optionally sends the file directly to the consumer or sends the location of the file to the consumer. File transport approach is not standardized. + +SA5 Rel 16 introduces the support of streaming trace from the provider to the consumer. Trace data for a trace session is collected and transmitted to the provider across a secure WebSocket connection in data bursts which are emitted frequently enough to ensure the relevance of the data while conserving transport resources. See section 2.4.6 and Annex C of this document for details on the streaming service. + +##### 2.4.1.2.2 Requirements + +Requirements for Trace Session Activation for file-based and streaming trace are found in TS 32.421 [21] Section 5.3.1. + +##### 2.4.1.2.3 Procedures + +Procedures for activating a Trace Session via management-based control are found in TS 32.422 [22] Section 4.1.1.1 for general procedures and TS 32.422 [22] Section 4.1.1.9 for NGRAN specific procedures. Procedures for activating a Trace Session via signaling are found in TS 32.422 [22] Section 4.1.2.1 and Section 4.1.2.16. + +#### 2.4.1.3 Trace Session Deactivation + +##### 2.4.1.3.1 Description + +A Trace Session is terminated/deactivated when any of the defined stop triggering events occur as specified in TS 32.421 [21], such as a timer expiring, or the TraceJob Session is deactivated via management control. + +##### 2.4.1.3.2 Requirements + +Requirements for Trace Session Deactivation are found in TS 32.421 [21] Section 5.4.1. + +##### 2.4.1.3.3 Procedures + +Procedures for Trace Session Deactivation are found in TS 32.422 [22] Section 4.1.3.10 for management-based trace deactivation and 4.1.4.1.2 for signalling-based trace deactivation. + +###### 756 2.4.1.4 Trace Recording Session Activation + +###### 757 2.4.1.4.1 Description + +758 A trace recording session is a specific instance of the data specified to be collected for a particular trace session, for +759 example, a specific call. For management-based activation, the trace recording session will start on a provider +760 configured with an active trace session when a triggering event occurs, such as a new call starting. Each Trace +761 recording session within a trace session has a unique trace recording session reference. This recording session reference +762 and the session reference are included with each trace record, uniquely identifying the trace record as belonging to a +763 particular trace recording session. For signaling-based activation, the Trace Recording Session starts when the NF +764 receives trace control and configuration parameters via a control signalling message. TS 32.422 [22] Section 4.3.2.12 +765 outlines the procedures the node is to follow when determining when to begin a new trace recording session and when +766 to continue with an existing session. + +###### 767 2.4.1.4.2 Requirements + +768 Requirements for Trace Recording Session Activation are found in TS 32.421 [21] Section 5.3.2. + +###### 769 2.4.1.4.3 Procedures + +770 Procedures for starting a Trace Recording Session are found in TS 32.422 [22] Section 4.2.1 for general requirements. +771 TS 32.422 [22] Section 4.2.2.10 has requirements for management-based trace session activation and 4.2.3.12 has +772 requirements when the trace session was activated via signaling. + +###### 773 2.4.1.5 Trace Recording Session Termination + +###### 774 2.4.1.5.1 Description + +775 A Trace Recording Session is terminated when any of the defined stop triggering events occur or the Trace Session is +776 deactivated. + +###### 777 2.4.1.5.2 Requirements + +778 Requirements for Trace Recording Session Termination are found in TS 32.421 [21] Section 5.4.2. + +###### 779 2.4.1.5.3 Procedures + +780 Procedures for Trace Recording Session Termination are found in TS 32.422 [22] Section 4.2.4.10 and 4.2.5.13. + +###### 781 2.4.2 Minimization of Drive Testing (MDT) + +###### 782 2.4.2.1 Description + +783 3GPP TS 37.320 [26] provides an overall description for MDT. An O-RAN network function may support Immediate +784 and Logged MDT as described in TS 37.320 [26]. Logged MDT will always be file-based. Immediate MDT may be +785 configured to be file-based or streaming. MDT measurements are described in 3GPP TS 37.320 [26]. 3GPP TS 32.421 +786 [17], 32.422 [22] and 32.423 [23] describe the management of MDT and have been updated to support 5G. + +###### 787 2.4.2.2 Requirements + +788 Requirements for managing MDT are found in TS 32.421 [21] Section 6. + +###### 789 2.4.2.3 Procedures + +790 Procedures for Trace Session Activation are the same for MDT as for Call Trace and are found in TS 32.422 [22] +791 section 4.1. Procedures for specifying MDT Trace selection conditions are found in TS 32.422 [22] section 4.1.5. + +792 Procedures for Trace Recording Sessions start and stop for MDT are found in TS 32.422 [22] section 4.2. + +793 Procedures for handling MDT sessions at handover for Immediate MDT are found in TS 32.422 [22] Section 4.4 and +794 Logged MDT in TS 32.422 [22] Section 4.5. + +795 Procedures for user consent handling in MDT are specified in TS 32.422 [22] Section 4.6. + +796 Procedures for MDT reporting are specified in TS 32.422 [22] Section 6. + +797 MDT Trace Record Contents are specified in TS 32.423[23] Section 4. + +798 Trace file format for MDT Trace is specified in TS 32.423 [23] Annex A2.1. Example XML files are provided in TS +799 32.423 [23] Annex D.1.4. + +###### 800 2.4.3 Radio Link Failure (RLF) + +###### 801 2.4.3.1 Description + +802 Radio Link Failure (RLF) reporting is a special Trace Session which provides the detailed information when a UE +803 experiences an RLF event and the reestablishment is successful to the source gNB. 3GPP TS 32.421 [21], 32.422 [22] +804 and 32.423 [23] describe the management of RLF. + +###### 805 2.4.3.2 Requirements + +806 Requirements for RLF are found in TS 32.421 [21] Section 7. + +###### 807 2.4.3.3 Procedures + +808 Procedures for Trace session activation and deactivation for RLF reporting are found in TS 32.422 [22] Section 4.3.1 +809 and 4.3.2. + +810 Procedures for specifying the RLF reporting job type when configuring the RLF reporting session are found in TS +811 32.422 [22] Section 5.9a. + +812 Procedures for RLF reporting follow standard trace reporting procedures documented in TS 32.422 [22] Section 7. + +###### 813 2.4.4 RRC Connection Establishment Failure (RCEF) + +###### 814 2.4.4.1 Description + +815 Radio Resource Control (RRC) Connection Establishment Failure (RCEF) is activated on the gNB as a special Trace +816 Session where the job type indicates RCEF reporting only. The records are produced when a UE experiences an RCEF +817 event and the RRC establishment is successful to the same gNB. + +###### 818 2.4.4.2 Requirements + +819 Requirements for RCEF are found in TS 32.421 [21] Section 7. + +###### 820 2.4.4.3 Procedures + +821 Procedures for trace session activation of RCEF are found in TS 32.422 [22] Section 4.8.1. + +822 Procedures for trace session deactivation for RCEF reporting are found in TS 32.422 [22] Section 4.8.2. + +823 Procedures for specifying the job type for RCEF are found in TS 32.422 [22] Section 5.9a. + +824 Procedures for RCEF Reporting are specified in TS 32.422 [22] Section 7. + +###### 825 2.4.5 Trace Control + +###### 826 2.4.5.1 Description + +827 Starting with 3GPP Release 16, Management-based Trace Control will be supported with IOCs with attributes that can +828 be read and/or set using generic provisioning mechanisms in the Trace Control Service. For Trace Control, this +829 includes operations such as Create TraceJob, Activate TraceJob, Deactivate TraceJob, and Query TraceJobs. TraceJobs +830 can be created, activated, deactivated and queried by setting and/or getting attributes in the TraceJob IOC. The +831 TraceJob IOC supports Management-based activation for Call Trace, MDT, RLF and RCEF. + +832 Trace sessions can also be activated and deactivated via signalingbased configuration initiated from another NF to +833 propagate a configured trace, such as a UE trace when the UE moves from one NF to another. + +###### 834 2.4.5.2 Requirements + +835 Management-based activation and deactivation will be done via the TraceJob IOC defined in TS 28.622 [14] Section +836 4.30. Requirements for TraceJob Activation are found in TS 32.421 [21] Section 5.3.1 and requirements for TraceJob +837 deactivation are found in TS 32.421 [21] Section 5.4.1. The requirements are applicable for both Management and +838 Signaling activation. + +###### 839 2.4.5.3 Procedures + +840 Management-based activation and deactivation will be accomplished using CRUD operations specified in section 2.1 of +841 this document. The attributes of the TraceJob are specified in TS 28.622 [14] Section 4.3.30.2. Constraints on these +842 attributes are specified in TS 28.622 [14] Section 4.3.30.3. Trace Control IOC mapping for management-based control +843 is found in TS 28.623 [15]. A CR to specify the YANG model for the Trace Control IOC has been approved in 3GPP +844 SA5 and will be incorporated into a future version of TS 28.623 [15]. . + +845 Procedures for Signaling-based Trace Session Activation are found in TS 32.422 [22] Section 4.1.2. + +846 Procedures for Trace Session Deactivation are found in TS 32.422 [22] Section 4.1.4. + +###### 847 2.4.6 Streaming Trace + +848 A NF can be configured to deliver trace data via a file or via a streaming interface. The streaming capability was +849 introduced in SA5 Release 16. The additional requirements and procedures supported for streaming trace are provided +850 in this section. An example of the configuration, activation, recording and termination of a streaming trace connection +851 are shown in Informative Annex C. + +###### 852 2.4.6.1 Streaming Trace Requirements and Procedures + +853 As noted above, trace session and recording activation and deactivation, as well as the content of the trace record, are +854 the same for file-based and streaming trace. The requirements for streaming trace delivery are found in TS 32.421 [21] +855 Section 5.5. Operations for establishing the streaming connection, adding and deleting streams from the connection and +856 reporting streaming trace data are found in TS 28.532 [4] Section 11.5. O-RAN NFs supporting streaming trace must +857 support the establishStreamingConnection, reportStreamData and terminateStreamingConnection operations. O-RAN +858 NFs that support the multiplexing of trace streams across a single connection must support the addStream and +859 deleteStream operations. Optionally, the NF may also support the getConnectionInfo and getStreamInfo operations +860 which allow the provider to query for information on the connection and streams on the connection. This is optional in +861 O-RAN as there are no use cases currently defined that require this operation. No notifications have been defined for +862 streaming trace. + +863 Stage 3 information on the streaming operations is provided in TS 28.532 [4] Section 12.5 with Open API YAML +864 definition provided in Annex 6.1.2. + +865 The procedure for establishStreamingConnection is an HTTP POST operation to provide the information on the stream +866 to the consumer and to receive the Connection ID as a response. The HTTP POST is followed by an HTTP GET to +867 upgrade the connection to a WebSocket connection. This operation is used when no connection is established between +868 the provider and the consumer. The WebSocket connection can contain one or more streams of data from streaming +869 trace or streaming PM. See TS 28.532 [4] Section 12.5.1.1.2. + +870 The terminateStreamingConnection is a WebSocket close frame operation. This operation is used when all streams on a +871 connection have terminated. See TS 28.532 [4] Section 12.5.1.1.3. + +872 The addStream Operation is an HTTP POST to indicate that additional streams are being added to the connection. A +873 stream is a trace job or a streaming PM job. See TS 28.532 [4] Section 12.5.1.1.5. + +874 The deleteStream Operation is an HTTP DELETE to indicate that a stream has been terminated from the connection. +875 See TS 28.532 [4] Section 12.5.1.1.6. + +876 The reportStreamData is a WebSocket data frame sent across the connection containing the streaming trace or +877 streaming PM data or an optional alive message indicating that the stream is active but no data is available. See TS +878 28.532 [4] Section 12.5.1.1.4. + +879 The getConnectionInfo Operation is an HTTP GET from the provider to the consumer to obtain information about the +880 connection, such as which streams are supported. See TS 28.532 [4] Section 12.5.1.1.7. + +881 The getStreamInfo Operation is an HTTP GET from the provider to the consumer to obtain information on the stream. +882 See TS 28.532 [4] Section 12.5.1.1.8. + +883 Annex C in this document provides a streaming trace activation example for management-based activation control. + +###### 884 2.5 File Management Services + +885 File management services allow a File Management MnS Consumer to request the transfer of files between the File +886 Management MnS Provider and the File Management MnS Consumer. + +887 Use cases are based on the O-RAN Fronthaul Management Plane Specification [30]. + +888 Relevant 3GPP specifications for file transfer are 3GPP TS 32.341 [17], TS 32.342 [18] and TS 32.346 [19]. +889 Alignment between 3GPP and O-RAN for File Management is targeted for 3GPP SA5 Rel 17. After the 3GPP CRs are +890 approved, this section will be updated to align with 3GPP. + +###### 891 2.5.1 File Ready Notification + +###### 892 2.5.1.1 Description + +893 The File Ready Notification notifies a File Management MnS Consumer that a file is available for upload from the File +894 Management MnS Provider. In general, File Management MnS Provider sends a notifyFileReady notification for files +895 that the File Management MnS Consumer has configured the File Management MnS Provider to collect on a periodic +896 basis, such as file-based Trace Data or PM Measurement Reports. + +###### 897 2.5.1.2 Requirements + +898 notifyFileReady notification event is a JSON encoded VES event, that consists of a Common VES Event Header and +899 notifyFileReady Notification Fields. It will be specified in 3GPP TS 28.532 [4] as part of the 3GPP/VES alignment +900 normative work. Until that time, the VES Event Listener Specification [31] specifies the FileReady notification. + +###### 901 2.5.1.3 Procedures + +902 File Management MnS Consumer configures a File Management MnS Provider to collect data files with specific +903 characteristics that the File Management MnS Consumer desires, such as file-based Trace Data or PM Measurement +904 Reports described in the Performance Assurance Section of this document. After configuration, the File Management +905 MnS Consumer terminates the configuration session and waits for the File Management MnS Provider to report that the +906 file is ready for collection. + +907 When a file is available, the File Management MnS Provider sends a notifyFileReady notification to the File +908 Management MnS Consumer using REST/HTTPS. + +![Sequence diagram showing a notifyFileReady Notification from File Management MnS Provider to File Management MnS Consumer. A note indicates 'New file is available on ME'.](3bf05e15fc285dd760ca38d290a5e87b_img.jpg) + +**notifyFileReady Notification** + +``` + +sequenceDiagram + participant FMC as File Management MnS Consumer + participant FMP as File Management MnS Provider + Note right of FMP: New file is available on ME + FMP->>FMC: 1 <> notifyFileReady Notification + +``` + +Sequence diagram showing a notifyFileReady Notification from File Management MnS Provider to File Management MnS Consumer. A note indicates 'New file is available on ME'. + +**Figure 2.5.1.3-1 File Available for Transfer to Consumer** + +Pre-condition: A new file is available on the File Management MnS Provider. + +1. File Management MnS Provider sends notifyFileReady notification to File Management MnS Consumer over HTTP/TLS. Mutual certificate authentication is performed. + +#### 2.5.1.4 Standards Additions to support O-RAN + +O-RAN will contact 3GPP reps to propose that the 3GPP/VES alignment includes re-naming of some fields within the notification to provide more clarity, such as renaming the changeIdentifier field in the Notification event supporting VES FileReady to a name more aligned with the field's purpose, such as fileType or to add an additional field called fileType which can be utilized to specify the type of file available for upload. The 3GPP specification will need to be updated if O-RAN wants to put specific naming conventions on the types of files that will be available for upload. + +O-RAN will request that 3GPP add FTPeS to the transport requirements supported in 3GPP TS 32.342 [18]. + +#### 2.5.1.5 File Types Supported + +File Type requirements are documented in 3GPP TS 32.341 [17] section 5.2. + +#### 2.5.1.6 File Naming Requirements + +File Naming requirements are specified in 3GPP TS 32.342 [18] Annex A. + +### 2.5.2 List Available Files + +#### 2.5.2.1 Description + +File Management MnS Consumer queries the File Management MnS Provider to identify files that are available on the File Management MnS Provider. Upon receipt of the available files and their locations, the File Management MnS Consumer can determine the next appropriate action. + +#### 2.5.2.2 Requirements + +Requirements on the types of files are found in section 5.4 of 3GPP TS 32.341 [17]. O-RAN may request that additional file types be specified in Rel-17 as part of the NRM fragment creation for List Available Files. + +#### 2.5.2.3 Procedures + +List Available Files Use Case allows the File Management MnS Consumer to obtain a list of available files and their locations by reading the AvailableFileList IOC as specified in 3GPP TS 32.342 [18]. A File Management MnS Consumer may use this management service in scenarios where the File Management MnS Provider is collecting information, such as logs, on a standard basis in support of debugging activities. Under normal operations, the File Management MnS Provider does not send this data to the File Management MnS Consumer as the File Management MnS Consumer does not need it. The File Management MnS Provider retains the data with the oldest data being overwritten when space is exhausted. In some scenarios, the File Management MnS Consumer may want to upload some, or all, of the available log files to resolve an issue. In this case, File Management MnS Consumer sends a NETCONF command to the File Management MnS Provider to obtain the list of available files. File Management MnS Provider responds with AvailableFileList which contains a list of available files and their locations and file types. File Management MnS Consumer may use this information to transfer the desired files. See Transfer File Service section 2.5.3. + +The File Management MnS Consumer does not have to initiate a file upload as a result of the obtaining the list of available files. There are use cases where the File Management MnS Consumer may want to verify that files are being collected or verify that all files of a particular type (PM for example) have been uploaded. + +![Sequence diagram showing the List Available Files procedure between File Management MnS Consumer and File Management MnS Provider. The steps are: [1] Establish NETCONF Session, [2] NETCONF , [3] NETCONF , and [4] Terminate NETCONF Session.](d6bac19d6278fb077736c828621dbd0b_img.jpg) + +**List Available Files** + +``` + +sequenceDiagram + participant C as File Management MnS Consumer + participant P as File Management MnS Provider + Note over C,P: [1] Establish NETCONF Session + Note over C,P: [2] NETCONF + Note over C,P: [3] NETCONF + Note over C,P: [4] Terminate NETCONF Session + +``` + +Sequence diagram showing the List Available Files procedure between File Management MnS Consumer and File Management MnS Provider. The steps are: [1] Establish NETCONF Session, [2] NETCONF , [3] NETCONF , and [4] Terminate NETCONF Session. + +**Figure 2.5.2.3-1 List Available Files** + +1. File Management MnS Consumer establishes NETCONF session with File Management MnS Provider. +2. File Management MnS Consumer sends NETCONF to the File Management MnS Provider to retrieve the contents of the AvailableFileList. +3. File Management MnS Provider sends NETCONF to the File Management MnS Consumer with list of available files on the File Management MnS Provider. +4. File Management MnS Consumer terminates NETCONF session with File Management MnS Provider. + +### 2.5.3 File Transfer by File Management MnS Consumer + +#### 2.5.3.1 Description + +The File Transfer by File Management MnS Consumer Use Case provides the capability for a File Management MnS Consumer to transfer files from or to the File Management MnS Provider. In this use case, File Management MnS Consumer is the client and File Management MnS Provider is the file server. + +- 969 The File Management MnS Consumer may perform this action as a result of: +- 970 1. notifyFileReady notification from the File Management MnS Provider informing the File Management +971 MnS Consumer that a file(s) is available + - 972 2. Querying the File Management MnS Provider for the list of available files (see section 2.5.2). + - 973 3. A need to transfer a file from a known location on the File Management MnS Provider. + - 974 4. A need to transfer a file to a known location on the File Management MnS Provider. Some examples of +975 files that could be transferred to the File Management MnS Provider are: + - 976 • Beamforming configuration file (Opaque Vendor specific data) + - 977 • Machine Learning + - 978 • Certificates +- 979 File Transfer is performed using a secure file transfer protocol (SFTP or FTPeS) from or to the File Management MnS +980 Provider. + +###### 981 2.5.3.2 Requirements + +982 File Transfer Requirements are found in Section 5.3 of 3GPP TS 32.341 [17]. + +###### 983 2.5.3.3 Procedures + +984 **Case 1:** File Management MnS Consumer determines that a file should be transferred from the the location provided by +985 the File Management MnS Provider as a result of receiving a notifyFileReady notification from the File Management +986 MnS Provider (described in 2.5.1). + +987 **Case 2:** File Management MnS Consumer determines that a file should be transferred from the File Management MnS +988 Provider as a result of receiving a list available files from the File Management MnS Provider (described in 2.5.2) + +989 **Case 3:** File Management MnS Consumer determines that a file should be transferred from the File Management MnS +990 Provider from a known location on the File Management MnS Provider. + +991 **Case 4:** File Management MnS Consumer determines that a file should be transferred to the File Management MnS +992 Provider to a known location on the File Management MnS Provider. + +993 File Management MnS Consumer initiates a secure file transfer using FTPeS or SFTP to transfer a file from or to the +994 File Management MnS Provider. + +##### File Transfer by File Management MnS Consumer. + +![Sequence diagram showing File Transfer by File Management MnS Consumer. It consists of two rows of boxes. The top row has 'File Management MnS Consumer' on the left and 'File Management MnS Provider' on the right. The bottom row has 'File Management MnS Consumer' on the left and 'File Management MnS Provider' on the right. A dashed line connects the two rows. A message arrow labeled '1 <> Transfer File' points from the top 'File Management MnS Consumer' box to the top 'File Management MnS Provider' box.](b0debcaa99ed0ff7a501fbfeb2af3f97_img.jpg) + +``` + +sequenceDiagram + participant C1 as File Management MnS Consumer + participant P1 as File Management MnS Provider + participant C2 as File Management MnS Consumer + participant P2 as File Management MnS Provider + C1-->>P1: 1 <> Transfer File + +``` + +Sequence diagram showing File Transfer by File Management MnS Consumer. It consists of two rows of boxes. The top row has 'File Management MnS Consumer' on the left and 'File Management MnS Provider' on the right. The bottom row has 'File Management MnS Consumer' on the left and 'File Management MnS Provider' on the right. A dashed line connects the two rows. A message arrow labeled '1 <> Transfer File' points from the top 'File Management MnS Consumer' box to the top 'File Management MnS Provider' box. + +995 + +996 + +997 + +998 **Figure 2.5.3.3-1 File Transfer by File Management MnS Consumer** + +999 + +### 2.5.4 Download File + +#### 2.5.4.1 Description + +The File Management MnS Consumer has a file that needs to be downloaded to the File Management MnS Provider such as: + +- Software file to upgrade software version executed on the File Management MnS Provider +- Beamforming configuration file (Opaque Vendor specific data) +- Machine Learning +- Certificates + +The File Management MnS Consumer triggers the file download. The File Management MnS Provider uses a secure file transfer protocol to download the file from the location specified by the File Management MnS Consumer and then notifies the File Management MnS Consumer of the result of the download. In this use case, the File Management MnS Provider is the client. The file could be located on any File Server reachable by the File Management MnS Provider. + +#### 2.5.4.2 Requirements + +General File Download requirements are found in section 5.3 of 3GPP TS 32.341 [17]. + +#### 2.5.4.3 Procedures + +![Sequence diagram for File Download procedure. The diagram shows three participants: File Management MnS Consumer, File Management MnS Provider, and File Server. The sequence of steps is: 1. Establish Netconf Session (Consumer to Provider), 2. NETCONF (Consumer to Provider), 3. NETCONF (Provider to Consumer), 4. Terminate Netconf Session (Consumer to Provider), 5. <> file download (Provider to File Server), 6. <> downloadFile Event (Provider to Consumer, optional), 7. <> downloadFile Event (Provider to Consumer).](d01978c5fb4e0374182da4ff635e5576_img.jpg) + +**File Download** + +``` + +sequenceDiagram + participant Consumer as File Management MnS Consumer + participant Provider as File Management MnS Provider + participant Server as File Server + + Consumer->>Provider: [1] Establish Netconf Session + Consumer->>Provider: [2] NETCONF + Provider-->>Consumer: [3] NETCONF + Consumer->>Provider: [4] Terminate Netconf Session + Provider->>Server: [5] <> file download + Note over Consumer, Provider: opt [Download Progress Notifications] + Provider->>Consumer: [6] <> downloadFile Event + Provider->>Consumer: [7] <> downloadFile Event + +``` + +Sequence diagram for File Download procedure. The diagram shows three participants: File Management MnS Consumer, File Management MnS Provider, and File Server. The sequence of steps is: 1. Establish Netconf Session (Consumer to Provider), 2. NETCONF (Consumer to Provider), 3. NETCONF (Provider to Consumer), 4. Terminate Netconf Session (Consumer to Provider), 5. <> file download (Provider to File Server), 6. <> downloadFile Event (Provider to Consumer, optional), 7. <> downloadFile Event (Provider to Consumer). + +**Figure 2.5.4.3-1 File Download** + +1. File Management MnS Consumer establishes NETCONF session with File Management MnS Provider. +2. File Management MnS Consumer sends NETCONF RPC file-download request, including the location of the file to download, to the File Management MnS Provider to trigger a file download. + +3. File Management MnS Provider replies with its ability to begin the download. +4. File Management MnS Consumer terminates NETCONF session with File Management MnS Provider. +5. File Management MnS Provider sets up a secure connection and downloads the file via FTPeS or SFTP. SFTP is authenticated with username/password, SSH keys or X.509 certificates. FTPES is authenticated with X.509 certificates. +6. (Optional) If the download takes a long time, File Management MnS Provider may send periodic downloadFile notifications to the File Management MnS Consumer with the current status of the download (download in progress). +7. When download completes, File Management MnS Provider sends a downloadFile notification to the File Management MnS Consumer with the final status of the download (success, file missing, failure). + +#### 2.5.4.4 Operations and Notifications + +downloadFile notification is a JSON encoded VES event sent from File Management MnS Provider to File Management MnS Consumer using REST/HTTPS. It consists of a Common VES Event Header and fileDownload Notification Fields to notify the File Management MnS Consumer of the progress and status of a file download. This event needs to be defined in VES and included in the 3GPP harmonization activity. + +## 2.6 Heartbeat Management Services + +Heartbeat MnS allow a Heartbeat MnS Provider to send heartbeats to the Heartbeat MnS Consumer and allow the Heartbeat MnS Consumer to configure the heartbeat services on the Heartbeat MnS Provider. + +Stage 1 Heartbeat MnS is specified in 3GPP TS 28.537 [6]. This Release 16 specification is aligned with the Services Based Management Architecture (SBMA) approach and contains Use Cases, Requirements and Procedures for configuring the heartbeat period, reading the heartbeat period, triggering an immediate heartbeat notification and emitting a periodic heartbeat notification. + +Stage 2 notifyHeartbeat notification is specified in 3GPP TS 28.532 [4]. + +Stage 2 HeartbeatControl IOC is specified in 3GPP TS 28.622 [14]. + +Stage 3 Solution Sets for XML, JSON and YANG are specified in 3GPP TS 28.623 [15]. + +### 2.6.1 Heartbeat Notification + +#### 2.6.1.1 Description + +Heartbeat MnS Provider sends asynchronous heartbeat notifications to Heartbeat MnS Consumer at a configurable frequency to allow Heartbeat MnS Consumer to supervise the connectivity to the Heartbeat MnS Provider. + +#### 2.6.1.2 Requirements + +Requirements for heartbeat notifications are specified in 3GPP TS 28.537 [6] section 4.2.2.2. + +#### 2.6.1.3 Procedures + +Procedures for heartbeat notifications are specified in 3GPP TS 28.537 [6] section 4.3.2 and 4.3.3. + +#### 2.6.1.4 Operations and Notifications + +An O-RAN heartbeat notification is a JSON encoded asynchronous notification sent from Heartbeat MnS Provider to Heartbeat MnS Consumer using REST/HTTPS. An O-RAN heartbeat notification must be in one of the following formats: + +1. 3GPP format: + +- A 3GPP notifyHeartbeat notification as specified in 3GPP TS 28.532 [4]. +- 2. VES format: + - A harmonized stdDefined VES event, consisting of a VES commonEventHeader and stdDefinedFields with a “data” element that contains a 3GPP notifyHeartbeat notification, as specified in 3GPP TS 28.532 [4]. The stdDefined VES event is specified in the VES Event Listener Specification [31]. Annex B in this document provides more information about stdDefined VES events. + - A legacy heartbeat VES event, consisting of a VES commonEventHeader and heartbeatFields, as specified in the VES Event Listener Specification [31], is also allowed for backward compatibility. However, a stdDefined VES event is the preferred VES format going forward. + +Two attributes are used to indicate the notification format: + +- notifFormatCapabilities indicates whether the provider supports 3GPP format, VES format or both. This attribute is set by the notification provider at the Managed Element level. It is read-only by the notification consumer. +- notifFormatConfig indicates whether the provider will send the notifications in 3GPP format or VES format. This attribute is set at the Managed Element level. This means all notifications from a provider are sent in the same format. The configuration is not per notification type. If the provider only supports one format, the provider sets the default value for this attribute to the supported format. Otherwise, if the provider supports both formats, the provider sets the default value for this attribute to VES format. In this second case, the consumer may change this value to 3GPP format. If the consumer attempts to set this attribute to a value not supported by the provider, the configuration will be rejected. + +It is not necessary to have an attribute to indicate whether harmonized VES or legacy VES is sent for VES format because the VES Event Registration artifact provided by the Network Function at onboarding time specifies the schema of the VES event. + +### 2.6.2 Heartbeat Control + +#### 2.6.2.1 Description + +Starting with 3GPP Release 16, dedicated operations for Management Services Use Cases will be supported by IOCs with attributes that can be read and/or set using generic provisioning mechanisms. For Heartbeat MnS, a Heartbeat Control IOC is specified in 3GPP TS 28.622 [14] that includes attributes to Get/Set Heartbeat Period, (heartbeatNtfPeriod) and Trigger Immediate Heartbeat (triggerHeartbeatNtf). . + +#### 2.6.2.2 Requirements + +Requirements for heartbeat control are specified in 3GPP TS 28.537 [6] section 4.2.2.1. + +#### 2.6.2.3 Procedures + +Procedures for heartbeat control are specified in 3GPP TS 28.537 [6] section 4.3.1 and 4.3.2. + +NETCONF protocol and YANG data models are used to read and configure the heartbeatNtfPeriod and triggerHeartbeatNtf in the HeartbeatControl IOC. Refer to the Provisioning management services section for procedures to read MOI attributes and modify MOI attributes using NETCONF. + +#### 2.6.2.4 HeartbeatControl IOC Definition + +HeartbeatControl IOC definition is specified in 3GPP TS 28.622 [14] section 4.3. + +YANG solution set for HeartbeatControl IOC is provided in 3GPP TS 28.623 [15] Annex D.2.6a. + +## 2.7 PNF Startup and Registration Management Services + +PNF Startup and Registration management services allow a physical PNF Startup and Registration MnS Provider to acquire its network layer parameters either via static procedures (pre-configured in the element) or via dynamic procedures (Plug-n-Play) during startup. During this process, the PNF Startup and Registration MnS Provider also acquires the IP address of the PNF Startup and Registration MnS Consumer for PNF Startup and Registration MnS Provider registration. Once the PNF Startup and Registration MnS Provider registers, the PNF Startup and Registration MnS Consumer can then bring the PNF Startup and Registration MnS Provider to an operational state. + +Relevant 3GPP specifications for PNF Plug-n-Play (PnP) are 3GPP TS 32.508 [24] and TS 32.509 [25]. Additional Plug-n-Play information for IPV6 and other O-RAN extensions can be found in O-RAN Fronthaul Management Plane Specification [30]. + +Alignment between 3GPP and O-RAN for PNF startup and registration is targeted for 3GPP SA5 Rel 17. Normative work includes an update to add the pnfRegistration event and an update to add new DHCP tags for IPv6 and O-RU. After the 3GPP CRs are approved, this section will be updated to align with 3GPP. + +### 2.7.1 PNF Plug-n-Play + +#### 2.7.1.1 Description + +PNF Plug-n-Play (PnP) scenario enables a PNF ME to obtain the necessary start-up configuration to allow it to register with a PNF Startup and Registration MnS Consumer for subsequent management. + +#### 2.7.1.2 Requirements + +Assuming O-RAN proposes a new Stage 1 spec for PNF Plug-n-Play and Registration, the PNF PnP requirements will be specified there. Until that time, the PNF PnP requirements are found in 3GPP TS 32.508 [24]. + +#### 2.7.1.3 Procedures + +Assuming O-RAN proposes a new Stage 1 spec for PNF Plug-n-Play and Registration, the PNF PnP procedures will be specified there. Until that time, the PNF PnP procedures are found in 3GPP TS 32.508 [24]. + +### 2.7.2 PNF Registration + +#### 2.7.2.1 Description + +PNF Startup and Registration MnS Provider sends an asynchronous pnfRegistration event to a PNF Startup and Registration MnS Consumer after PnP to notify PNF Startup and Registration MnS Consumer of new PNF Startup and Registration MnS Provider to be managed. + +#### 2.7.2.2 Requirements + +Assuming O-RAN proposes a new Stage 1 spec for PNF Plug-n-Play and Registration, the PNF Registration requirements will be specified there. Until that time, the PNF Registration requirements are provided in the VES Event Listener Specification [31]. + +#### 2.7.2.3 Procedures + +Assuming O-RAN proposes a new Stage 1 spec for PNF Plug-n-Play and Registration, the PNF Registration procedures will be specified there. Until that time, the PNF Registration procedures are provided in this O1 Interface Specification. + +#### 2.7.2.4 Procedures + +![Sequence diagram for PNF Registration Notification. It shows two instances of 'PNF Startup and Registration MnS Consumer' and 'PNF Startup and Registration MnS Provider'. The top instance of the Provider sends a 'PnP completes' note and then a message '1 <> pnfRegistration Event' to the top instance of the Consumer. The top instance of the Consumer then sends a 'Register PNF' note to the bottom instance of the Consumer.](b63ac5aadf6cbac66c8a34c1fbc95400_img.jpg) + +**PNF Registration Notification** + +``` + +sequenceDiagram + participant C1 as PNF Startup and Registration MnS Consumer + participant P1 as PNF Startup and Registration MnS Provider + participant C2 as PNF Startup and Registration MnS Consumer + participant P2 as PNF Startup and Registration MnS Provider + + Note over P1: PnP completes + P1->>C1: 1 <> pnfRegistration Event + Note over C1: Register PNF + C1->>C2: + +``` + +Sequence diagram for PNF Registration Notification. It shows two instances of 'PNF Startup and Registration MnS Consumer' and 'PNF Startup and Registration MnS Provider'. The top instance of the Provider sends a 'PnP completes' note and then a message '1 <> pnfRegistration Event' to the top instance of the Consumer. The top instance of the Consumer then sends a 'Register PNF' note to the bottom instance of the Consumer. + +**Figure 2.7.2.4-1 PNF Registration Notification** + +Pre-condition: PNF completes Plug-n-Play. + +1. PNF Startup and Registration MnS Provider sends pnfRegistration notification VES event to PNF Startup and Registration MnS Consumer over HTTP/TLS. Mutual certificate authentication is performed. + +Post-condition: PNF Startup and Registration MnS Consumer registers the PNF Startup and Registration MnS Provider so that it can be managed. + +#### 2.7.2.5 Operations and Notifications + +pnfRegistration notification is a JSON encoded VES event sent from PNF Startup and Registration MnS Provider to PNF Startup and Registration MnS Consumer using REST/HTTPS. It consists of a Common VES Event Header and pnfRegistration Notification Fields. + +pnfRegistration notification event will be specified in 3GPP TS 28.532 [4] as part of the 3GPP/VES alignment normative work. Until that time, the pnfRegistration notification is specified in the VES Event Listener Specification [31]. + +## 2.8 PNF Software Management Services + +Software management services allow a PNF Software MnS Consumer to request a physical PNF Software MnS Provider to download, install, validate and activate a new software package and allow a physical PNF Software MnS Provider to report its software versions. O-RAN will utilize the liaison to 3GPP to initiate enhancements to the 3GPP specifications for PNF Software Management. Until those enhancements are put in place, O-RAN PNF Software Management will be described in this specification. Software management described in this document is modeled on the O-RAN Fronthaul Management Plane Specification [30]. + +Alignment between 3GPP and O-RAN for PNF software management is targeted for 3GPP SA5 Rel 17. After the 3GPP CRs are approved, this section will be updated to align with 3GPP. + +### 2.8.1 Software Package Naming and Content + +PNF Software Package naming, content and format are vendor specific and do not require standardization in O-RAN. A PNF Software Package may contain one or more files. Some of the files in the Software Package may be optional for the PNF (example: a file that has not changed version). The PNF is aware of the content and format of its available Software Packages and can determine which files it needs to download. + +The softwarePackage Managed Object Class (MOC) contains attributes about a software package such as: software package name, version, fileList, integrityStatus (valid, invalid, empty), runningState (active, passive), vendor, productName, softwareType (operational, factory), etc. This MOC is applicable to VNFs and PNFs and is a generic term that O-RAN will use to refer to the software available on the PNF rather than the legacy term of software slot + +The PNF creates one instance of softwarePackage for each software package supported concurrently on the PNF. Typically, a PNF will have two softwarePackage MOIs for operational software; one with runningState = active and one with runningState = passive. Some PNFs also have a softwarePackage MOI for the factory software which would be read only. O-RAN may have PNFs that support more than one passive slot. In this case the inventory query result would show multiple MOIs with runningState=passive. + +### 2.8.2 Software Inventory + +#### 2.8.2.1 Description + +The PNF Startup and Registration MnS Consumer sends a Software Inventory Request and retrieves information about the software packages on the PNF Software MnS Provider. + +#### 2.8.2.2 Requirements + +Requirements are to be specified in a 3GPP spec for PNF Software Management. Until that time, the requirements are provided in this O1 Interface Specification. + +REQ-SWI-FUN-1: The PNF software management service provider SHALL have the capability to provide its authorized consumer information about the software packages on the PNF software management service provider. + +#### 2.8.2.3 Procedures + +![Sequence diagram for Software Inventory procedure between PNF Software MnS Consumer and PNF Software MnS Provider.](daf3e91a76c1c43764c638aaf3966785_img.jpg) + +**Software Inventory** + +``` + +sequenceDiagram + participant Consumer as PNF Software MnS Consumer + participant Provider as PNF Software MnS Provider + Note over Consumer, Provider: [1] Establish NETCONF Session + Note over Consumer, Provider: [2] NETCONF + Note over Provider: Retrieve Software Inventory Information + Note over Consumer, Provider: [3] NETCONF + Note over Consumer, Provider: [4] Terminate NETCONF Session + +``` + +The diagram illustrates the Software Inventory procedure. It shows two participants: PNF Software MnS Consumer and PNF Software MnS Provider. The sequence of steps is as follows: 1. Establish NETCONF Session (bidirectional arrow). 2. NETCONF (arrow from Consumer to Provider). 3. Retrieve Software Inventory Information (note on Provider side). 4. NETCONF (arrow from Provider to Consumer). 5. Terminate NETCONF Session (bidirectional arrow). + +Sequence diagram for Software Inventory procedure between PNF Software MnS Consumer and PNF Software MnS Provider. + +**Figure 2.8.2.3-1 Software Inventory** + +1. PNF Software MnS Consumer establishes NETCONF session with PNF Software MnS Provider. The NETCONF session has authorized read privileges into the identified section of the data store. + +2. PNF Software MnS Consumer sends NETCONF to retrieve an optionally filtered subset configuration from the running configuration datastore. can be used to identify the software package MOIs. GET retrieves configuration and operational-state of softwarePackage MOIs. +- a. PNF Software MnS Provider retrieves software inventory information. +3. PNF Software MnS Provider returns requested data in NETCONF response. +4. PNF Software MnS Consumer terminates NETCONF session with PNF Software MnS Provider. + +### 2.8.3 Software Download + +#### 2.8.3.1 Description + +Software Download triggers the download of a specific software package to the PNF Software MnS Provider. This download service includes integrity checks on the downloaded software and the installation of the software into the software slot corresponding to the softwarePackage MOI. + +#### 2.8.3.2 Requirements + +Requirements are to be specified in a 3GPP spec for PNF Software Management. Until that time, the requirements are provided in this O1 Interface Specification. + +REQ-SWD-FUN-1: The PNF software management service provider SHALL have the capability to allow its authorized consumer to specify the location of software that is to be downloaded and to specify into which softwarePackage the software is to be stored. + +REQ-SWD-FUN-2: The PNF software management service provider SHALL have the capability to verify if a software download is in progress and the ability to reject subsequent download commands until the one in progress completes. + +REQ-SWD-FUN-3: The PNF software management service provider SHALL have the capability to deny download of software if the download request is not valid for the PNF software management service provider. + +REQ-SWD-FUN-4: The PNF software management service provider SHALL have the capability to download needed files from a software server at a specified location. + +REQ-SWD-FUN-5: The PNF software management service provider SHALL have the capability to perform integrity checks on downloaded software. + +REQ-SWD-FUN-6: The PNF software management service provider SHALL have the capability to install the software into the software slot corresponding to the softwarePackage MOI identified by its authorized consumer in the download command. The PNF software management service provider SHALL not allow installation of newly downloaded software into the running software slot. + +#### 2.8.3.3 Procedures + +![Sequence diagram for Software Download procedure. Participants: PNF Software MnS Consumer, PNF Software MnS Provider, Software Server. Steps: 1. Establish NETCONF Session. 2. NETCONF . 3. NETCONF . 4. Terminate NETCONF Session. 5. <> file download. 6. <> downloadFile Event (optional). 7. <> downloadFile Event. Internal actions: Validate Request, Integrity check SW, Install SW into slot, Update softwarePackage.](1080f6fcceb1b06309d52abdda5551ef_img.jpg) + +**Software Download** + +``` + +sequenceDiagram + participant Consumer as PNF Software MnS Consumer + participant Provider as PNF Software MnS Provider + participant Server as Software Server + + Consumer->>Provider: [1] Establish NETCONF Session + Consumer->>Provider: [2] NETCONF + Note over Provider: Validate Request + Provider-->>Consumer: [3] NETCONF + Consumer->>Provider: [4] Terminate NETCONF Session + Provider->>Server: [5] <> file download + Note over Provider: Integrity check SW + Note over Provider: Install SW into slot + Note over Provider: Update softwarePackage + opt [Download Progress Notifications] + Provider->>Consumer: [6] <> downloadFile Event + end + Provider->>Consumer: [7] <> downloadFile Event + +``` + +Sequence diagram for Software Download procedure. Participants: PNF Software MnS Consumer, PNF Software MnS Provider, Software Server. Steps: 1. Establish NETCONF Session. 2. NETCONF . 3. NETCONF . 4. Terminate NETCONF Session. 5. <> file download. 6. <> downloadFile Event (optional). 7. <> downloadFile Event. Internal actions: Validate Request, Integrity check SW, Install SW into slot, Update softwarePackage. + +**Figure 2.8.3.3-1 Software Download** + +1. PNF Software MnS Consumer establishes NETCONF session with PNF Software MnS Provider. The NETCONF session has authorized execution privileges for retrieve file list and file-download rpcs. +2. PNF Software MnS Consumer sends NETCONF to trigger a download of the software located at remoteFilePath and save its information in softwarePackage. + - a. PNF Software MnS Provider validates the request. Validation includes determining if the operation can be performed. This is PNF Software MnS Provider specific but could include things like: checking that there is not a software download already in progress, softwarePackage is runningState = passive and softwareType = operational, etc. +3. PNF Software MnS Provider returns NETCONF . +4. PNF Software MnS Consumer terminates NETCONF session with PNF Software MnS Provider. +5. PNF Software MnS Provider initiates SFTP or FTPES connection and downloads the software package from remoteFilePath. SFTP is authenticated with username/password, SSH keys or X.509 certificates. FTPES is authenticated with X.509 certificates. PNF Software MnS Provider understands the software package format and downloads all the files it needs from the package. PNF Software MnS Provider decides where to store the software internally. This is PNF Software MnS Provider specific but could be a temporary location like /tmp. + - a. PNF Software MnS Provider integrity checks the downloaded software. This is PNF Software MnS Provider specific but could include checking-checksum, correct software for the hardware, etc. + - b. PNF Software MnS Provider installs software into the software slot corresponding to the softwarePackage. + +1253 c. PNF Software MnS Provider updates softwarePackage; name, version, fileList, integrityStatus, +1254 runningState, etc. + +1255 6. (Optional) If the download takes a long time, PNF Software MnS Provider may send periodic downloadFile +1256 notifications to the PNF Software MnS Consumer with the current status of the download (download in +1257 progress, integrity checks passed, install complete). + +1258 7. When download operation completes, PNF Software MnS Provider sends downloadFile notification to PNF +1259 Software MnS Consumer with the final status of the download (success or the reason for failure). + +###### 1260 2.8.3.4 Operations and Notifications + +1261 downloadFile notification is a JSON encoded VES event sent from PNF Software MnS Provider to PNF Software MnS +1262 Consumer using REST/HTTPS. It consists of a Common VES Event Header and fileDownload Notification Fields to +1263 notify the PNF Software MnS Consumer of the progress and status of a file download. This event needs to be defined +1264 in VES and included in the harmonization activities between 3GPP and VES. + +1265 + +###### 1266 2.8.4 Software Activation Pre-Check + +###### 1267 2.8.4.1 Description + +1268 Activation Pre-check is an optional Use Case that the Service Provider may choose to utilize prior to software activation +1269 to confirm that the PNF Software MnS Provider is in a good state to activate the new software and provide information +1270 needed for planning the timing of the software replacement--such as whether a reset or a data migration is required. + +###### 1271 2.8.4.2 Requirements + +1272 Requirements are to be specified in a 3GPP spec for PNF Software Management. Until that time, the requirements are +1273 provided in this O1 Interface Specification. + +1274 REQ-SPC-FUN-1: The PNF software management service provider SHALL have the capability to confirm that the +1275 software in the passive slot targeted for activation is good. + +1276 REQ-SPC-FUN-2: The PNF software management service provider SHALL have the capability to determine whether +1277 the activation of the targeted software requires a reset and/or data migration. + +###### 1278 2.8.4.3 Procedures + +1279 + +![Sequence diagram for Activation Pre-Check between PNF Software MnS Consumer and PNF Software MnS Provider.](b1e01cf3eb34bf2d796d681411c8a107_img.jpg) + +**Activation Pre-Check** + +``` + +sequenceDiagram + participant C as PNF Software MnS Consumer + participant P as PNF Software MnS Provider + Note over C,P: [1] Establish NETCONF Session + Note over C,P: [2] NETCONF + Note over P: Perform Pre-Check + Note over C,P: [3] NETCONF + Note over C,P: [4] Terminate NETCONF Session + +``` + +The diagram illustrates the 'Activation Pre-Check' process. It involves two main entities: 'PNF Software MnS Consumer' and 'PNF Software MnS Provider'. The process follows these steps: [1] Establish NETCONF Session, [2] NETCONF , [3] NETCONF , and [4] Terminate NETCONF Session. A callout box labeled 'Perform Pre-Check' is associated with the provider's side during step [2]. + +Sequence diagram for Activation Pre-Check between PNF Software MnS Consumer and PNF Software MnS Provider. + +**Figure 2.8.4.3-1 Software Activation Pre-Check** + +1. PNF Software MnS Consumer establishes NETCONF session with PNF Software MnS Provider. +2. PNF Software MnS Consumer sends NETCONF to trigger a pre-check of the software stored in softwarePackage and to return the results of the pre-check. + - a. PNF Software MnS Provider performs the activation pre-check which includes validating that the software in softwarePackage is good, whether the activation of the software in softwarePackage will result in a reset and whether data migration is needed, etc. +3. PNF Software MnS Provider returns NETCONF to the PNF Software MnS Consumer with the results of the pre-check. +4. PNF Software MnS Consumer terminates NETCONF session with PNF Software MnS Provider. + +### 2.8.5 Software Activate + +#### 2.8.5.1 Description + +PNF Software MnS Consumer triggers the activation of a software package on the PNF Software MnS Provider including data migration and reset if needed. + +#### 2.8.5.2 Requirements + +Requirements are to be specified in a 3GPP spec for PNF Software Management. Until that time, the requirements are provided in this O1 Interface Specification. + +REQ-SWA-FUN-1: The PNF software management service provider SHALL have the capability to allow its authorized consumer to activate valid software in a specific softwarePackage. + +REQ-SWA-FUN-2: The PNF software management service provider SHALL have the capability to verify whether a software activation is in progress and deny a concurrent activation of software. + +1306 REQ-SWA-FUN-3: The PNF software management service provider SHALL have the capability to deny activation of +1307 software if the activation request is not valid for the PNF software management service provider. + +1308 REQ-SWA-FUN-4: The PNF software management service provider SHALL have the capability to activate the +1309 softwarePackage. + +1310 REQ-SWA-FUN-5: The PNF software management service provider SHALL have the capability to reset the PNF +1311 software management service provider if the software activation requires it. + +1312 REQ-SWA-FUN-6: The PNF software management service provider SHALL provide the capability for the PNF +1313 software management service provider to send a re-set reason notification to its authorized consumer if the activation +1314 results in a reset. + +1315 REQ-SWA-FUN-7: The PNF software management service provider SHALL have the capability to perform data +1316 migration on the PNF software management service provider if the software activation requires it. + +1317 REQ-SWA-FUN-8: The PNF software management service provider SHALL have the capability to fallback to the +1318 previously active software if the new software cannot be activated. + +1319 REQ-SWA-FUN-9: The PNF software management service provider SHALL have the capability to fallback to the +1320 factory software if the new and the previously active software can not be activated. + +###### 1321 2.8.5.3 Procedures + +1322 + +##### Software Activate + +![Sequence diagram for Software Activate process between PNF Software MnS Consumer and PNF Software MnS Provider.](711f84033566e82bde67f2d385ef2cbe_img.jpg) + +``` + +sequenceDiagram + participant Consumer as PNF Software MnS Consumer + participant Provider as PNF Software MnS Provider + + Consumer->>Provider: [1] Establish NETCONF Session + Provider->>Consumer: [2] NETCONF + Note over Provider: Validate request + Provider-->>Consumer: [3] NETCONF + Consumer->>Provider: [4] Terminate NETCONF Session + Note over Provider: Activate Software + + alt [if Data Migration or Reset are needed then] + alt [if Data Migration Needed then] + Note over Provider: Migrate Data if needed + end + alt [if Reset Needed then] + Note over Provider: Reset + Provider->>Consumer: [5] <> resetReason Event + end + end + + alt [if Activation fails then] + Note over Provider: Fallback if failure + end + + opt [Activation Progress Notifications] + Provider->>Consumer: [6] <> softwareActivate Event + Provider->>Consumer: [7] <> softwareActivate Event + Note over Provider: Config change occurs + Provider->>Consumer: [8] <> notifyMOIAttributeValueChange Event + end + + Note over Consumer: Reconcile Database + +``` + +The diagram illustrates the 'Software Activate' process between the PNF Software MnS Consumer and the PNF Software MnS Provider. The process begins with the Consumer establishing a NETCONF session with the Provider. The Provider then sends a NETCONF message to the Consumer. A note 'Validate request' is associated with the Provider's side of this step. The Provider then sends a NETCONF message back to the Consumer. The Consumer then sends a message to Terminate the NETCONF Session. A note 'Activate Software' is associated with the Provider's side of this step. An alternative block [if Data Migration or Reset are needed then] contains two sub-alternatives: [if Data Migration Needed then] with a note 'Migrate Data if needed', and [if Reset Needed then] with a note 'Reset' and a message [5] <> resetReason Event from the Provider to the Consumer. Another alternative block [if Activation fails then] contains a note 'Fallback if failure'. An optional block [Activation Progress Notifications] shows the Provider sending [6] <> softwareActivate Event, [7] <> softwareActivate Event, a note 'Config change occurs', and [8] <> notifyMOIAttributeValueChange Event to the Consumer. Finally, a note 'Reconcile Database' is associated with the Consumer's side of the process. + +Sequence diagram for Software Activate process between PNF Software MnS Consumer and PNF Software MnS Provider. + +1323 + +1324 + +1325 + +**Figure 2.8.5.3-1 Activate Software** + +1. PNF Software MnS Consumer establishes NETCONF session with PNF Software MnS Provider. +2. PNF Software MnS Consumer sends NETCONF to trigger an activation of the software in softwarePackage. + - a. PNF Software MnS Provider validates the request. This is PNF Software MnS Provider specific but could include things like checking that there is not a software activation already in progress, softwarePackage is runningState = passive and integrityStatus = valid, etc. +3. PNF Software MnS Provider returns status to the PNF Software MnS Consumer in the NETCONF response. + - a. PNF Software MnS Provider performs the steps needed to make the softwarePackage the active one. This is PNF Software MnS Provider specific but includes things like updating the runningState of the about-to-be-active and previously-active software packages. +4. PNF Software MnS Consumer terminates NETCONF session with PNF Software MnS Provider. + +(Optional) PNF Software MnS Provider performs data migration if necessary. PNF Software MnS Provider knows whether this is necessary. +5. (Optional) PNF Software MnS Provider performs reset if necessary. PNF Software MnS Provider knows whether reset is necessary. If a reset occurs, PNF Software MnS Provider sends a resetReason notification to the PNF Software MnS Consumer with the reason for the reset; in this case software activation. + +(Optional) If the PNF Software MnS Provider can not activate the software, PNF Software MnS Provider shall have recovery logic to fallback to the previously active software and potentially fallback to the factory software in a worst-case scenario. +6. (Optional) If the activation takes a long time, PNF Software MnS Provider may send periodic softwareActivate notifications to PNF Software MnS Consumer with the current status of the activation (e.g. activation in progress, data migration successful). +7. After activation operation completes, PNF Software MnS Provider sends a softwareActivate notification to PNF Software MnS Consumer with the final status of the activation. +8. PNF Software MnS Provider sends notifyMOIAttributeValueChange to the PNF MnS Consumer updating the active software running on the PNF. + +#### 2.8.5.4 Operations and Notifications + +softwareActivate notification is a JSON encoded VES event sent from PNF Software MnS Provider to PNF Software MnS Consumer using REST/HTTPS. It consists of a Common VES Event Header and softwareActivate Notification Fields to notify the PNF Software MnS Consumer of the progress and status of a software activation. + +resetReason notification is a JSON encoded VES event sent from PNF Software MnS Provider to PNF Software MnS Consumer using REST/HTTPS. It consists of a Common VES Event Header and resetReason Notification Fields to notify the PNF Software MnS Consumer that a reset has occurred and the reason for the reset. + +These events need to be defined in VES and included in the harmonization activities between 3GPP and VES. + + + +# Annex A: (Informative) O-RAN Performance Measurement Definition Example + +## A.1 3GPP TS 32.404 PM Template Usage + +Two examples are presented below to illustrate how to use the 3GPP TS 32.404 [20] template to specify already defined O-RAN O-RU performance measurements. The sample template is shown first, followed by a snippet of the corresponding 3GPP XML PM file for illustration purposes. These examples are not intended to be precise definitions of counters but are intended to show how one can convert two existing O-RU counters to conform to the 3GPP TS 32.404 [20] template format. The O-RAN defined PM counters will be defined and documented by the Working Groups producing them; e.g. WG4 for O-RU, WG5 for O-DU, etc. + +We expect that the Working Groups will create a template similar to table A.1.1.1 for each counter defined and that these tables will be part of the official documentation. The XML files do not need to be included in the Working Group documents. + +### A.1.1 Example 1 How O-RU Transport counts for Transceiver RX Power could be defined following 3GPP TS 32.404. + +#### A.1.1.1 PM Template + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RUT.RxPower | +| Description | Measurement provides the number of times the Transceiver RX optical power measured in mW is in a particular range. Transceiver RX power is sampled every transceiver-measurement-interval during the granularity period. transceiver-measurement-interval is a configurable parameter. This measurement has 10 subcounters representing 10 mW ranges. This measurement is reported per QSFP (per O-RU, per port, per lane). | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the sampled Transceiver RX Power is in the range represented by the subcounter Binx . | +| Measurement Result | Integer number | +| Measurement Type | OR.RUT.RxPower. Binx where
Bin1 is the range .0001 to .32
Bin2 is the range .3201 to .64
Bin3 is the range .6401 to .96
Bin4 is the range .9601 to 1.28
Bin5 is the range 1.2801 to 1.6
Bin6 is the range 1.6001 to 1.92
Bin7 is the range 1.9201 to 2.24
Bin8 is the range 2.2401 to 2.56
Bin9 is the range 2.5601 to 2.88
Bin10 is the range 2.8801 to 3.2 | +| Measurement Object Class | QSFP | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.1.2 Example 2 How O-RU Transport counts for Receive Window might be defined following the 3GPP TS 32.404 template + +#### A.1.2.1 PM Template + +| | | +|------------------|----------------------| +| Measurement Name | OR.RUT.ReceiveWindow | +|------------------|----------------------| + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Description | Measurement provides the number of times user data was received in the reception window under a particular condition. This measurement has 6 subcounters representing the following conditions; received on time, received too early, received too late, received corrupted or with an incorrect packet header, received a duplicate packet and total messages received. This measurement is reported per EAXC Id. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the user data is received under the conditions represented by the subcounter Conditionx . | +| Measurement Result | Integer number | +| Measurement Type | OR.RUT.ReceiveWindow. Conditionx where Conditionx is
RxOnTime when the user data is received on time
RxEarly when the user data is received early
RxLate when the user data is received late
RxCorrupted when the user data is received corrupted or the packet header is incorrect
RxDuplicate when the user data packet is a duplicate
RxTotalMsgs to represent the total number of messages received | +| Measurement Object Class | EAXC Id | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +21 + +22 + +# Annex B: (Informative) Guidelines and Example for stdDefined VES Events + +## B.1: Guidelines for use of stdDefined VES for sending 3GPP MnS notifications + +3GPP has published an informative Annex B in TS 28.532 [4] providing guidelines for the integration of 3GPP MnS notifications with VES. This Annex expands on the information provided by 3GPP. + +When an O-RAN and 3GPP compliant ME supports VES stdDefined events for sending asynchronous notifications, the native 3GPP notification, as defined by 3GPP, is included in the event. + +A VES common event header, as defined by VES Event Specification v7.2 [31], is added to the notification. + +In VES, the domain field in the common event header is used to route the event to the proper consumers and to map to a schema for the event payload. VES Event Specification v7.2 [31] added a new domain field enumeration value called stdDefined that indicates that the event is complying with a schema defined by a standards body. + +An additional field was added to the VES common event header called stdDefinedNamespace, which contains a valid namespace as defined by the standards body. This field is only populated when the domain is stdDefined. 3GPP has defined four namespaces in TS 28.532 [4] Annex B; namely 3GPP-Provisioning, 3GPP-Heartbeat, 3GPP-FaultSupervision and 3GPP-PerformanceAssurance. A VES collector uses the stdDefinedNamespace, along with the stdDefined domain, to route the event to the correct consumer. + +A stdDefined VES event has a field structure called stdDefinedFields, specified in VES Event Specification v7.2 [31]. This structure contains three properties: + +- schemaReference (type = string, format = uri) +- data (JSON object which should be identical to the 3GPP notification) +- stdDefinedFieldsVersion (type = string, format = enum) + +The schemaReference, if present, should be used to verify that the notification content is correct. 3GPP is publishing the notification schemas, in JSON format, to a public repository, () so that schema references can be included in the event. + +The data element contains the 3GPP notification, in JSON format, as specified in 28.532 [4]. + +The stdDefinedFieldsVersion provides the version of the stdDefinedFields structure, as defined by VES Event Specification v7.2 [31]. + +Annex B.2 provides an example of a stdDefined VES event for a new alarm notification. + +## B.2: Example stdDefined VES event for a new alarm notification + +The following example illustrates the population of a new alarm notification using a stdDefined VES event. + +The VES Common Header is shown from line 44 through line 58. Note that it contains: + +- the domain set to stdDefined +- the stdDefinedNamespace set to 3GPP-FaultSupervision. + +The stdDefinedFields structure begins on line 59. Note that it contains: + +- the 3GPP schema reference for the 3GPP fault notification type +- the data element which contains the full 3GPP notifyNewAlarm fault notification + +- the version of the stndDefinedFields. + +``` + +{ "event": { + "commonEventHeader": { + "domain": "stndDefined", + "eventId": "stndDefined-gNB-Nokia-000001", + "eventName": "stndDefined-gNB-Nokia", + "lastEpochMicrosec": 1594909352208000, + "priority": "Normal", + "reportingEntityName": "NOKb5309", + "sequence": 0, + "sourceName": "NOKb5309", + "startEpochMicrosec": 1594909352208000, + "stndDefinedNamespace": "3GPP-FaultSupervision", + "version": "4.1", + "timeZoneOffset": "UTC-05.00", + "vesEventListenerVersion": "7.2" + }, + "stndDefinedFields": { + "schemaReference": https://forge.3gpp.org/rep/sa5/5G_APIs/blob/REL-16/(...)/ + faultNotifications.json#definitions/notifyNewAlarm-NotifType, + "data": { + "href": 1, + "uri": "xyz", + "notificationId": "123", + "notificationType": "notifyNewAlarm", + "eventTime": "xyz", + "systemDN": "xyz" + "probableCause": "High Temperature", + "perceivedSeverity": "Major", + "rootCauseIndicator": false, + "specificProblem": "7052", + "backedUpStatus": true, + "backUpObject": "xyz", + +``` + +``` +75 "trendIndication": "No change", +76 "thresholdInfo": {}, +77 "stateChangeDefinition": {}, +78 "monitoredAttributes": [], +79 "proposedRepairActions": "xyz", +80 "additionalText": "xyz", +81 "additionalInformation": [], +82 "alarmId": "15", +83 "alarmType": "Environmental Alarm" +84 } +85 }, +86 "stdDefinedFieldsVersion": "1.0" +87 } +88 } +89 +``` + +- +- 1 **Annex C: (Informative) Streaming Trace Management** + - 2 **Activation Example** + - 3 Example with Management-based Trace Activation, Data Reporting and Deactivation for Streaming Trace follows. + +![Sequence diagram showing the interaction between Provisioning MnS Consumer, Trace MnS Provider, and Trace MnS Consumer for streaming trace connection establishment, data reporting, and deactivation.](a96acae994afddb6e8afdf33166dc4e5_img.jpg) + +**Streaming Trace Connection Establishment, Data Reporting and Deactivation** + +``` + +sequenceDiagram + participant PMnS as Provisioning MnS Consumer + participant TMnSP as Trace MnS Provider + participant TMnSC as Trace MnS Consumer + + PMnS->>TMnSP: [1] Trace Job Configuration create traceJob MOI + TMnSP-->>PMnS: [2] notifyMOIChanges + TMnSP->>TMnSC: [3] establishStreamingConnection (HTTP POST request (SourceID, Trace Session Information)) + TMnSC-->>TMnSP: [4] HTTP: response (Connection ID) + TMnSP->>TMnSC: [5] HTTP GET request(Connection ID, Upgrade Header) + TMnSC-->>TMnSP: [6] HTTP: response (Sec-WebSocket-Accept) + TMnSP->>TMnSP: [7] Start Trace Session + + loop [(for each "start"triggering event detected)] + TMnSP->>TMnSC: [8] Start Trace Recording Session and allocate new TRS (embedded in a reportStreamData Operation) + TMnSP->>TMnSC: [9] StartRecordingSession() + loop [(until "stop"triggering event is detected)] + loop [(while reporting condition is not satisfied)] + TMnSP->>TMnSC: [10] Capture trace record + end + alt [(there are trace records to report)] + TMnSP->>TMnSC: [11] "reportStreamData(traceRecords)" + else [(there are no trace records to report)] + TMnSP->>TMnSC: [12] "reportStreamData(IsAlive())" + end + end + TMnSP->>TMnSP: [13] Stop Trace Recording Session + TMnSP->>TMnSC: [14] StopRecordingSession()(embedded in a reportStreamData Operation) + end + + PMnS->>TMnSP: [15] Trace Session Deactivation/Configuration + TMnSP->>TMnSC: [16] Stop Trace Session (embedded in a reportStreamData Operation) + + loop [(for each on-going Trace Recording Session)] + TMnSP->>TMnSP: [17] Stop Trace Recording Session + opt [(there are outstanding trace records)] + TMnSP->>TMnSC: [18] "reportStreamData(traceRecords)" + end + TMnSP->>TMnSC: [19] StopRecordingSession()(embedded in a reportStreamData Operation) + TMnSP->>TMnSC: [20] deleteStream Operation (HTTP DELETE) + TMnSP->>TMnSC: [21] No Active Streams remain: terminateStreamingConnection(WebSocket Close Frame) + TMnSP->>TMnSC: [22] Terminate Connection + end + +``` + +The diagram illustrates the sequence of operations for establishing, reporting, and deactivating a streaming trace connection. It involves three main entities: Provisioning MnS Consumer, Trace MnS Provider, and Trace MnS Consumer. + +**Sequence of Operations:** + +- [1] Trace Job Configuration create traceJob MOI (Provisioning MnS Consumer to Trace MnS Provider) +- [2] notifyMOIChanges (Trace MnS Provider to Provisioning MnS Consumer) +- [3] establishStreamingConnection (HTTP POST request (SourceID, Trace Session Information)) (Trace MnS Provider to Trace MnS Consumer) +- [4] HTTP: response (Connection ID) (Trace MnS Consumer to Trace MnS Provider) +- [5] HTTP GET request(Connection ID, Upgrade Header) (Trace MnS Provider to Trace MnS Consumer) +- [6] HTTP: response (Sec-WebSocket-Accept) (Trace MnS Consumer to Trace MnS Provider) +- [7] Start Trace Session (Trace MnS Provider self-call) +- Loop: [(for each "start"triggering event detected)]** + - [8] Start Trace Recording Session and allocate new TRS (embedded in a reportStreamData Operation) (Trace MnS Provider to Trace MnS Consumer) + - [9] StartRecordingSession() (Trace MnS Provider to Trace MnS Consumer) + - Loop: [(until "stop"triggering event is detected)]** + - Loop: [(while reporting condition is not satisfied)]** + - [10] Capture trace record (Trace MnS Provider to Trace MnS Consumer) + - Alt: [(there are trace records to report)]** + - [11] "reportStreamData(traceRecords)" (Trace MnS Provider to Trace MnS Consumer) + - Alt: [(there are no trace records to report)]** + - [12] "reportStreamData(IsAlive())" (Trace MnS Provider to Trace MnS Consumer) + - [13] Stop Trace Recording Session (Trace MnS Provider self-call) + - [14] StopRecordingSession()(embedded in a reportStreamData Operation) (Trace MnS Provider to Trace MnS Consumer) +- [15] Trace Session Deactivation/Configuration (Provisioning MnS Consumer to Trace MnS Provider) +- [16] Stop Trace Session (embedded in a reportStreamData Operation) (Trace MnS Provider to Trace MnS Consumer) +- Loop: [(for each on-going Trace Recording Session)]** + - [17] Stop Trace Recording Session (Trace MnS Provider self-call) + - Opt: [(there are outstanding trace records)]** + - [18] "reportStreamData(traceRecords)" (Trace MnS Provider to Trace MnS Consumer) + - [19] StopRecordingSession()(embedded in a reportStreamData Operation) (Trace MnS Provider to Trace MnS Consumer) + - [20] deleteStream Operation (HTTP DELETE) (Trace MnS Provider to Trace MnS Consumer) + - [21] No Active Streams remain: terminateStreamingConnection(WebSocket Close Frame) (Trace MnS Provider to Trace MnS Consumer) + - [22] Terminate Connection (Trace MnS Provider to Trace MnS Consumer) + +Sequence diagram showing the interaction between Provisioning MnS Consumer, Trace MnS Provider, and Trace MnS Consumer for streaming trace connection establishment, data reporting, and deactivation. + +**Figure C-1 : Streaming Trace Connection Establishment, Data Reporting and Deactivation Example** + +6 + +###### 7 Scenario + +1. Provisioning Management Service Consumer activates/configures Trace Session on Trace Provider. This will be accomplished using Provisioning Management services described in Section 2.1 of this document. +2. Trace Provider sends a notifyMOIChanges to indicate the new MOI is created. +3. Trace Provider needs to establish a connection to the Trace Consumer to set up a streaming connection (streams are active at this time between the Provider and Consumer). This is done using the establishStreamingConnection Operation via an HTTP POST request containing MetaData associated with this Trace Session. +4. Trace Consumer responds with an acknowledgement that contains the ConnectionID needed by the Provider when requesting that the connection be upgraded to a WebSocket to support streaming of the trace data. +5. Trace Provider requests the upgrade of the connection to a WebSocket using the ConnectionID and an HTTP GET operation. +6. Trace Consumer accepts the upgrade and WebSocket is established. WebSocket will remain connected until the last streaming trace session active on the Trace Provider is ended. Note in this example, only one streaming trace session is active. +7. Trace Provider starts trace session, waiting for triggering event to occur. +8. Triggering event occurs and a new trace recording session is started on the Trace Provider. Each trace recording session has a unique Trace Recording Session (TRS) Reference associated with it. +9. Trace Provider sends Trace Data to Trace Consumer indicating that this is the start of a new trace record session. The start trace recording session information is included in the reportStreamingData Operation. +10. While this trace record is active, the Trace Provider collects trace data. +11. When the reporting timer expires or enough trace data is available, the Trace Provider sends a trace data report to the Trace Consumer containing trace record data for active recording sessions in a trace session. These records are the payload of the reportStreamingData operation. +12. If the timer expires, but no trace data is present on the Trace Provider, the producer will send an alive message to the Trace Consumer to confirm that the session is still active. The alive message is the payload of the reportStreamingData operation. +13. When the criteria for the trace recording session completion occurs (call ends, etc.), the Trace Provider stops collecting data for this trace recording session. +14. Trace Provider creates a record that indicates this trace recording session has ended and includes this record in the payload of the reportStreamingData operation to the Trace Consumer. +15. Provisioning Management Service Consumer deactivates the trace via procedures defined in section 2.1 of this document. Deactivation means that the trace data collection should cease, and the Trace Provider should stop all active trace recording sessions and send data that it has collected up to this point, if any, for each active trace recording to the Trace Consumer. +16. Trace Provider initiates the termination of the trace session. +17. For each active session, Trace Provider initiates a Stop Trace Recording Session. +18. If there are outstanding record(s) for this trace recording session that have not been streamed to the Trace Consumer, Trace Provider sends them as the payload of the reportStreamingData operation. +19. Trace Provider informs the Trace Consumer that this Trace Recording Session has ended by sending the trace record termination via the reportStreamingData Operation. The producer repeats this until all trace recording sessions for this trace session have been terminated. +20. In this example, only one stream was on the connection, so the WebSocket should be disconnected. To accomplish this, Trace Provider sends the Trace Consumer the deleteStream operation indicating that this Trace Session has been terminated. +21. When all active Trace Sessions between Trace Provider and Trace Consumer have ended, the WebSocket connection is to be torn down. In this example, this occurs when this session terminates because only one session is active. To terminate the session, Trace Provider sends the Trace Consumer the terminateSignalingConnection Operation which is a WebSocket close frame. +22. WebSocket connection is torn down. + +# Annex ZZZ: O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an ORAN Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, + +use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of ORAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. + +O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance's sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. + +Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or third party beneficiary's right to assert + +143 or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full +144 force and effect. + +145 + +--- + +146 + +147 \ No newline at end of file diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/009314d991a0bb3dd5a6093017b094ad_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/009314d991a0bb3dd5a6093017b094ad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bf0a527a0778fb2d16647a149708481cd477b6cd --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/009314d991a0bb3dd5a6093017b094ad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f385847e43abc5e6c16a32e6cdcecb3e0787cd3da9849c013f5c606217838a02 +size 4065 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/05bb679f635c5a18dac76d4a4f21d07d_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/05bb679f635c5a18dac76d4a4f21d07d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..683ebcd5f5f45739ba75ef041874550dc3ef0e1f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/05bb679f635c5a18dac76d4a4f21d07d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b773d0910ca5945c15985ad456f47879fbc751cf4e8f5a69a8057eb6401525ae +size 4063 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/17b3d3e9bb0c5e4b0545a40379a36494_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/17b3d3e9bb0c5e4b0545a40379a36494_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1cdb4e388705d82c4913de8133d2ccef43e21a02 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/17b3d3e9bb0c5e4b0545a40379a36494_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:97e1791364a0cad1dab04c1b6d1a9f665d73c3f55d92b7a19fe0c10abd040c3d +size 4044 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/1adeea95f60e02679278c5920c1d2073_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/1adeea95f60e02679278c5920c1d2073_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..61a814410a4c50a8d094195cf35d348f528a57c5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/1adeea95f60e02679278c5920c1d2073_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6f4e74172617d124a957b727922d56c3d3028de53e302558bcd09abaab29d197 +size 151985 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2a3f0fdfb526ff3f41a88651692ccde5_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2a3f0fdfb526ff3f41a88651692ccde5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7f70549ca8e4ff919341a32a9847e7966d7ca501 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2a3f0fdfb526ff3f41a88651692ccde5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9015fa74c7fa5b090c5419769fca7334688aea670f7bb9d5fa2b3c1ef3843a5c +size 4030 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2ae2b95770ac4be81072d7fff4db2153_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2ae2b95770ac4be81072d7fff4db2153_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a3061ce1b284559df005689644d6ab4673b11631 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2ae2b95770ac4be81072d7fff4db2153_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0f6676f7bc2b02cbb12ce0c609bc83a4ffbfb609e314a2a090bfdc4e863eeeee +size 48505 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2b7095d8ec9e7509aefaa08903ce194f_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2b7095d8ec9e7509aefaa08903ce194f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b99014713ff43f475495de58077b99084f9e7841 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2b7095d8ec9e7509aefaa08903ce194f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3026ee853cc58dc37678e07ad8c0d041c13b434f22dfcfd100f868e7e3e3dd1a +size 149544 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2ea4a39bcadb72f2666d673f037c0bb7_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2ea4a39bcadb72f2666d673f037c0bb7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9c2e7bc915ccf58fd4cd7a27246b1d77da39a538 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2ea4a39bcadb72f2666d673f037c0bb7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5fc72232ede2c7a8f6a5cbfd94462071212899a6ad05ac572c068144c518b0ab +size 54904 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2f0f03faa4a7a8c407741f3a2a7e80cc_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2f0f03faa4a7a8c407741f3a2a7e80cc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c11266c634acae33ef27a08fa3b9f046727edc9b --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/2f0f03faa4a7a8c407741f3a2a7e80cc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8adf7da42dd01d330708b99fdfafdb02c70459f46cf9c06f4fb4e9a0565d6c6c +size 44987 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/33a4db925b455250193a2b85a0a64434_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/33a4db925b455250193a2b85a0a64434_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..591ce1f888cf982f3d1d986877b374fb4f96d931 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/33a4db925b455250193a2b85a0a64434_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:041ba4b1a08a3f5af3cae756632e12970621c52a15fa7f5c57867214660a652b +size 16573 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/3a5731e56852fbad66c92f17a9d821a5_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/3a5731e56852fbad66c92f17a9d821a5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a5438fed8c3f467da7f04586325ceb78eb982b89 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/3a5731e56852fbad66c92f17a9d821a5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2981c4b82a2877cccfc69df1b0bde2efcbe8174d35777f2d752e97805ee7e048 +size 40998 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/4f10155f97ab961ef9e5ca17b4ec89c8_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/4f10155f97ab961ef9e5ca17b4ec89c8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4aa39672481fedf10abcc873660b30d7d37b9933 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/4f10155f97ab961ef9e5ca17b4ec89c8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:38331faf24d711a394dfae8c8d0592fc9f029ff747cec3c33c4a967cf6d3599c +size 185715 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/4f2fd1bd24583f321e09b5189b21facf_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/4f2fd1bd24583f321e09b5189b21facf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ef33e74746be51934eedd0be06a4a612efee369e --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/4f2fd1bd24583f321e09b5189b21facf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ae889ec6afd743f04bf38b45ac7dad41b3a9866c9089b086aa513163dbe9087e +size 18362 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/4f3a52c49b2a187b4861ce1aa9bb2ef7_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/4f3a52c49b2a187b4861ce1aa9bb2ef7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fe9c7748147af1692693d9e8148d6a529ca2af30 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/4f3a52c49b2a187b4861ce1aa9bb2ef7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9e2371afe2330871dbfcd5750d38c4dfb984edf7045e4c04196ea6e8f60bcceb +size 25156 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/57f4eeef16b695bc408f5435d1a85102_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/57f4eeef16b695bc408f5435d1a85102_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cffa341c8e2518e897b7d9ed49cee28537752522 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/57f4eeef16b695bc408f5435d1a85102_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8ca4a4ec02577dc30b0547139f7da3d447d21461179bb10c943749f0cf06f5eb +size 134520 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/5c5a1d09f19f5e6ad84c385c791bb007_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/5c5a1d09f19f5e6ad84c385c791bb007_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..00af118af6971f7db2ad90ad4eb39a701631ab0d --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/5c5a1d09f19f5e6ad84c385c791bb007_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5e3b023e9b51074b26fe6d5a08712fe4af05253d93cd50346a540b031160dfcd +size 27734 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/60afaba41ed5e87be9368a1a55391b40_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/60afaba41ed5e87be9368a1a55391b40_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e4b9d12ecf444a26869904b20f12c01741512ee --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/60afaba41ed5e87be9368a1a55391b40_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1809d283f544d3907c4f5f5eb451e7311efd8506bf359e1dc48fe596d615b7f1 +size 41737 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/6934367c554f2aa08d13477a6e9bc324_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/6934367c554f2aa08d13477a6e9bc324_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c76f540715077b5eecbcd064ff1c357fa1692f93 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/6934367c554f2aa08d13477a6e9bc324_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:933fae4246ef69ae98023e207910e0a3a8d41f860e5a3308be09c726498f73ec +size 33510 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/6b7fecacf715441b907ed4db9dcaef62_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/6b7fecacf715441b907ed4db9dcaef62_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..acd01d0f14aebfe12c735b5d1fc5ab9ba5b7096c --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/6b7fecacf715441b907ed4db9dcaef62_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0419e5bb6d87864773230aaf94a59ca7137e92f350365f7ff7045f91ca672fa3 +size 267669 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/7d25338b1b3e000c5c51743620ded318_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/7d25338b1b3e000c5c51743620ded318_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5bd18696610fe12dbb36329b5e92dda6aa96f2a9 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/7d25338b1b3e000c5c51743620ded318_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e1829af216869c0e99e0d6019cda7ecb718f88d0a504901c3764423fcb46602d +size 49958 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/826091f3b1e383141f439bf9c248489e_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/826091f3b1e383141f439bf9c248489e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8d3ac21b062ee27295f9b8ef1eeb0bc8ba98c40b --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/826091f3b1e383141f439bf9c248489e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1ae9f679cb975f49aca120b20ee8aa5369f6107c6ca5848244f981570b69ef58 +size 55102 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/84b3c55c644e95de07e42dc9cfb55621_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/84b3c55c644e95de07e42dc9cfb55621_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..135640b93e747977bd82ec9775d6a5138d55822b --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/84b3c55c644e95de07e42dc9cfb55621_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cbe6f6db62c441f0b21a84c1bfe126c0a150d389cbccdc7bbd284ed72eaab684 +size 151471 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/878c4377bd16b8009ae07442559e889a_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/878c4377bd16b8009ae07442559e889a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..674d4b45787c71401a5fe5e62b3191603db4c9b9 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/878c4377bd16b8009ae07442559e889a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:26be60fa8f33ce5cc1e51a64c2f4dd2218abb2fc8bcd1b0b081afe4ca9f28f5a +size 23011 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/88aca3358e5b5e5ed706373dd744e5e0_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/88aca3358e5b5e5ed706373dd744e5e0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..022a999febd9a19c49fdcfb9f34f4c4687897fe5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/88aca3358e5b5e5ed706373dd744e5e0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1a8047f55e68198edbfce18d8d87f5e8e003cc20f62b42ad8d25fb1920a52e03 +size 46452 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/8d804d479c235afe1fdbbe29a65a12d6_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/8d804d479c235afe1fdbbe29a65a12d6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..394c93d334f2c0c52bd1b6ab18e344490ba320ef --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/8d804d479c235afe1fdbbe29a65a12d6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4f52a69a8c6e2c04bdc0cc81f09754b7da0b1e44d4ff5313507e0ba622e4cf7d +size 4046 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/8fe38b0370b903ca42cb063805ca34f9_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/8fe38b0370b903ca42cb063805ca34f9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..67d1e1910bd6fc91eb472ced0430f333f6928427 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/8fe38b0370b903ca42cb063805ca34f9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ed05a30a060af3820c5021695cca552f52431e21e7b46326a32550c3def98d8b +size 4065 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/9d2074faa6badaafc64c9c09cd1d96f2_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/9d2074faa6badaafc64c9c09cd1d96f2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bf19a68a539cd9a80dee30c33deb8ace675ded4a --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/9d2074faa6badaafc64c9c09cd1d96f2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1baaf818ffc3bf92cfbdc17bd4dfd3b578249e5970a08b2cf28392892e8fc6af +size 31691 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/a1755af0837868e049d85932c9b4b766_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/a1755af0837868e049d85932c9b4b766_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..43d20756fe387dd15a68a862bd0ba893e441db11 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/a1755af0837868e049d85932c9b4b766_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:08ca56f07f79fc05cb31ae820c31c6ec95a0c1c7b3ff2aba74bc2b4988247f9e +size 10845 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/aa21b04a298a324f28bf198cd47e38a1_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/aa21b04a298a324f28bf198cd47e38a1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..47605c07aa42853148e50c2e7d08de06e773fef6 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/aa21b04a298a324f28bf198cd47e38a1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:72f2f1f29079e41cea756f46d02b71119a85022348b878be755ca747646e7aea +size 45054 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/b4b42adb2f1ac70e17db52a41ce055c4_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/b4b42adb2f1ac70e17db52a41ce055c4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c43974185a7ef4f732195eab9af8fe24ad4ea8fa --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/b4b42adb2f1ac70e17db52a41ce055c4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:672a078a234da967fba37bb44289d307e715557c96b84b9aa041e55fe77d2fd0 +size 96752 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/b8bf649faf1855a088cfce273add9323_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/b8bf649faf1855a088cfce273add9323_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ec0a8062be158da9978f55a6c6970b0e74cfd113 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/b8bf649faf1855a088cfce273add9323_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:932c969277df784425a4ef36e26ef7a5333be89ef2243a76a69a30075eb211e8 +size 44437 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/bb383139c47d9296247dbab9a475f148_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/bb383139c47d9296247dbab9a475f148_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4a8ec08b481a78b789ffdb8300ddbd59a43385a8 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/bb383139c47d9296247dbab9a475f148_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cdc5c23ab5c87c7ab90d2df3fa7097ece9a49097ec5a5224280fbfbc886f28b +size 4063 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/bf632c49a2d728e3d215e688183d2115_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/bf632c49a2d728e3d215e688183d2115_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d259c4601153c0aced43c1b6350032755478a1a5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/bf632c49a2d728e3d215e688183d2115_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:40505c6a92acca4a4974305a366a46c051e3180c792d1af6aab53d35787b9163 +size 39924 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/bfac6c1518721cc987c75cbc8f9b697d_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/bfac6c1518721cc987c75cbc8f9b697d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..edc460017bf9e0b695a73f7c03beef2fd37a0be6 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/bfac6c1518721cc987c75cbc8f9b697d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f7a62208d6a12cb7667c9edbc9d8bf8684bbbb88ac85c2790f92a97230cca1f2 +size 43727 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/c1c07bc558389cbdd94f5bb3fc26b49f_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/c1c07bc558389cbdd94f5bb3fc26b49f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b6e3f28cef82b27a53dbcca494686d2e837bbabc --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/c1c07bc558389cbdd94f5bb3fc26b49f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:21e688ca6f2dd65798741f8f6d2368a4e7eb2682c411edcc68d438741857ee3f +size 45571 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/c32d31a80f79e90161732a44b049171e_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/c32d31a80f79e90161732a44b049171e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7f39cdc97aaadbfcf5c2b7cc79a8c86921f49ad0 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/c32d31a80f79e90161732a44b049171e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:00ecc252f98ad96f8d79cf188d012181e848147b1f7c6e1e9e8f974f221372c4 +size 78721 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/c8fcd327fc94ea5df3260fea6137a570_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/c8fcd327fc94ea5df3260fea6137a570_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..740925ab21d7f3cbc6d08aa408db8df00b1fff85 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/c8fcd327fc94ea5df3260fea6137a570_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a7c266d5003bbcd79208c35800f528b53333ed35b63daf6ce4cfe4792639c9da +size 67492 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/ceed3363e355a3606fb80b028aee05b3_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/ceed3363e355a3606fb80b028aee05b3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f7d7aa1c440b29ff738d10adbd3d68bbe8b72521 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/ceed3363e355a3606fb80b028aee05b3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4669450bde5be209b00f3f52c8d53aa872e84b615816ac915f77d1202e710ed6 +size 175099 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/d8c0094380fbcff6a72e58e0a35d043c_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/d8c0094380fbcff6a72e58e0a35d043c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6d50f038bf8ad271111af8c9556136f0b268a7d7 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/d8c0094380fbcff6a72e58e0a35d043c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:276939eef9cd0a7441f3f1c86a65896e2beed8d64c2c321ebbd99481fcf4fc48 +size 13834 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/dafc7301db467f8e91f196ad69565e78_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/dafc7301db467f8e91f196ad69565e78_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bca6c705e1a801c61b552bb3044f9dc634894911 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/dafc7301db467f8e91f196ad69565e78_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:063dbbaf0dd9360950ec9d9ee3772443f3806fc3b75258e6406102825a94c775 +size 20162 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/db0be88c08f50a86f90cf5db3788e79d_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/db0be88c08f50a86f90cf5db3788e79d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d292dbf1054aea12373f170dd05e2b9b6d925b5e --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/db0be88c08f50a86f90cf5db3788e79d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7fc0abcd6379125cc97b3c6e48d195390912fb007bd5827bc546c5a691d5585b +size 32355 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/e1d4ec23982efb28dcd6fda23a2f68a6_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/e1d4ec23982efb28dcd6fda23a2f68a6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5dd430d0615644f8b8371f5a5162cf60e6a9dd68 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/e1d4ec23982efb28dcd6fda23a2f68a6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1d6d230b14cd8db72eee7824ba18913cc336a7cd40a73dfcf706096424153fe5 +size 82881 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/ec3dd01aafb74614d8c185d813cd4ae0_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/ec3dd01aafb74614d8c185d813cd4ae0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..57e3b7ca156fe021ff9f0d723895a4b989ecd3d2 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/ec3dd01aafb74614d8c185d813cd4ae0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6c25f52a439200e4e60c0dfc8c5f0b71e84956175a97c231b4287147f7199db7 +size 46524 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/f94522878c4d2f1caa321216dd75d223_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/f94522878c4d2f1caa321216dd75d223_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7caffc39a130b3ddf4decb8e49826b133d5304ee --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/f94522878c4d2f1caa321216dd75d223_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:19540a1acf5693d11de4b5f846f126dc085bee088eacae80252653015e6fd430 +size 46778 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/fa5442e7947b5f35e47ee6ea42cc9434_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/fa5442e7947b5f35e47ee6ea42cc9434_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..95e3364ea8f8a4e1f13a191b9aa7056096b02f12 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/fa5442e7947b5f35e47ee6ea42cc9434_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d2ec5f554f3c70464b2a10aca22879b4241b30e43cef4abbbe9da52cbd7004be +size 150294 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/fba6bf9826da19a2daa3bf12bb3d9c08_img.jpg b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/fba6bf9826da19a2daa3bf12bb3d9c08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a924a948e0b0cbb620672fa1eeaf472c5feb09e8 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/fba6bf9826da19a2daa3bf12bb3d9c08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:26161248e5cd47d092ede7dbb3a392b537d02668477c66ecc4150117baf988bb +size 4027 diff --git a/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/raw.md b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..0084348549c94b428968286850e694c189aa8553 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.OAM-Architecture-v04.00/raw.md @@ -0,0 +1,1916 @@ + + +# O-RAN Operations and Maintenance Architecture --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Operations and Maintenance Architecture** --- + +Copyright © 2021 by the O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in Annex *ZZZ* of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +# Contents + +| | | | +|-------------|--------------------------------------------------------------|----| +| Chapter 1. | Introductory Material ..... | 3 | +| 1.1 | Scope ..... | 3 | +| 1.2 | References..... | 3 | +| 1.3 | Definitions and Abbreviations ..... | 4 | +| 1.3.1 | Definitions..... | 4 | +| 1.3.2 | Abbreviations ..... | 5 | +| Chapter 2. | O-RAN Overview ..... | 6 | +| 2.1 | Scope and Objectives..... | 6 | +| 2.2 | End to End OAM Use Cases..... | 6 | +| 2.2.1 | O-RAN Service Provisioning..... | 6 | +| 2.2.2 | O-RAN Measurement Data Collection ..... | 11 | +| Chapter 3. | OAM Architecture ..... | 19 | +| 3.1 | Architectural Principles ..... | 19 | +| 3.2 | Architecture Requirements ..... | 19 | +| 3.2.1 | Functional Requirements..... | 19 | +| 3.2.2 | Non-Functional Requirements ..... | 20 | +| 3.2.3 | Security Requirements ..... | 20 | +| 3.3 | Reference Architecture ..... | 20 | +| 3.3.1 | Architectural Building Blocks..... | 20 | +| 3.3.2 | Basic OAM Architecture..... | 23 | +| 3.3.3 | OAM Models and Deployment Options..... | 23 | +| 3.3.4 | Managed Elements Deployed behind a NAT ..... | 28 | +| Chapter 4. | Application Lifecycle Management (LCM) ..... | 30 | +| 4.1 | Scope ..... | 30 | +| 4.1.1 | Information Model ..... | 31 | +| 4.1.2 | Diagramming Legend..... | 33 | +| 4.1.3 | App Development Lifecycles..... | 33 | +| 4.1.4 | App Onboarding Lifecycles ..... | 35 | +| 4.1.5 | App Operation Lifecycles ..... | 37 | +| 4.2 | Common Application Lifecycle Conclusions ..... | 37 | +| Appendix A: | Cardinality ..... | 38 | +| Appendix B: | Sequence Diagram Template ..... | 39 | +| Annex A: | SMO and Non-RT RIC mapping with 3GPP management system ..... | 49 | +| Annex ZZZ : | O-RAN Adopter License Agreement ..... | 51 | +| Section 1: | DEFINITIONS ..... | 51 | +| Section 2: | COPYRIGHT LICENSE ..... | 51 | +| Section 3: | FRAND LICENSE ..... | 51 | +| Section 4: | TERM AND TERMINATION ..... | 52 | +| Section 5: | CONFIDENTIALITY ..... | 52 | +| Section 6: | INDEMNIFICATION ..... | 52 | +| Section 7: | LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 53 | +| Section 8: | ASSIGNMENT ..... | 53 | +| Section 9: | THIRD-PARTY BENEFICIARY RIGHTS ..... | 53 | +| Section 10: | BINDING ON AFFILIATES ..... | 53 | +| Section 11: | GENERAL..... | 53 | + +# Chapter 1. Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG1 and may change following formal o-RAN approval. Should the o-RAN.org modify the contents of the present document, it will be re-released by o-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +The present document studies O-RAN OAM architecture and interface functions. The OAM architecture supports a variety of management network deployment models, including the model of management entities (NMS/EMS/MANO) connecting directly to NEs, and the indirect connection (e.g., M-Plane involved) model. A separate OAM interface document provides details of the functions and protocols conveyed over the interface, that include management functions, procedures, operations and corresponding solutions. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. + - For a specific reference, subsequent revisions do not apply. + - For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 15. +- [1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications" + - [2] 3GPP TS 38.401: "NG-RAN; Architecture description". + - [3] 3GPP TS 28.622: "Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS)". + - [4] 3GPP TS 32.101: "Telecommunication management; Principles and high level requirements". + - [5] 3GPP TS 28.532: Management and orchestration; Generic management services + - [6] 3GPP TS 28.533: Management and orchestration; Architecture framework + - [7] 3GPP TS 28.550: Management and orchestration; Performance assurance + - [8] 3GPP TS 28.552: Management and orchestration; 5G performance measurements + - [9] ETSI GS NFV-IFA 005 V3.3.1 (2019-08), Network Functions Virtualisation (NFV) Release 3; Management and Orchestration; Or-Vi reference point - Interface and Information Model Specification + - [10] ETSI GS NFV-IFA 027 V2.4.1 (2018-05), Network Functions Virtualisation (NFV) Release 2; Management and Orchestration; Performance Measurements Specification + - [11] O-RAN White Paper: "O-RAN: Towards an Open and Smart RAN", October 2018 + +- [12] O-RAN-WG4.MP.0-v05.00: O-RAN Alliance Working Group 4 Management Plane Specification +- [13] O-RAN.WG1.O1-Interface-v04.00: “O-RAN Operations and Maintenance Interface Specification”. +- [14] ORAN.WG2.Use Case Requirements v01.00: “O-RAN Working Group 2 (Non-RT RIC & AI interface)”. +- [15] O-RAN.WG6.CAD-v02.00, “Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN” +- [16] O-RAN.WG6.ORB-v02.00, “Orchestration Use Cases for O-RAN Virtualized RAN” +- [17] O-RAN.WG1-O-RAN Architecture Description - v03.00: “O-RAN Architecture Description”. +- [18] ORAN.WG3.E2GAP.0-v0.1: “O-RAN Working Group 3; Near-Real-time RAN Intelligent Controller Architecture & E2 General Aspects and Principles”. +- [19] O-RAN.WG3.RICARCH-v01.00: “O-RAN Working Group 3;Near-Real-time RAN Intelligent Controller; Near-RT RIC Architecture” +- [20] 3GPP TR 28.809 v0.2.0, Study on enhancement of management data analytics +- [21] O-RAN-WG6.O2-GA&P-v01.00: “O2 General Aspects and Principles v.01.00” +- [22] , "YAML Ain't Markup Language (YAML™) Version 1.2", October 2009 +- [23] O-RAN.WG1.Information Model and Data Models-v01.00: “O-RAN Information Model and Data Models Specification” + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [1]. + +Also, any terms and definitions that are also given in the O-RAN Architecture [17] are intended to be aligned. Text in the O-RAN Architecture [17] takes precedence in case of any difference. + +**infrastructure resources:** Infrastructure resources as used here refer to a set of resources provided to a VNF [9] by its supporting O-Cloud. + +**Service Planning:** The activity of a Service Operator around certifying a solution configuration for deployment into their network. + +**Service Provider:** A network provider who is planning to deploy applications into their network. + +**Solution Provider:** An application developer who delivers applications to Service Providers. + +**"SP" Exchange:** Not a formal interface in terms of between systems. However, the structure and content of the exchange is defined such that a Solution Provider can deliver applications to a Service Provider for deployment. + +Definitions for the following terms used in the document can be found in the O-RAN Architecture [17]: + +**near-RT RIC** + +**non-RT RIC** + +**NMS** + +**O-Cloud** + +**O-CU** + +**O-CU-CP** + +**O-CU-UP** + +**O-DU** + +**O-RU** + +**O1** + +**O2** +**SMO** +**rApp** +**xApp** + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [1]. + +| | | +|-------------|---------------------------------------------------------| +| FCAPS | Fault, Configuration, Accounting, Performance, Security | +| FOCOM | Federated O-Cloud Orchestration and Management | +| MA | Managed Application | +| ME | Managed Element | +| MF | Managed Function | +| MMP | Meet-Me-Point | +| NAT | Network Address Translation | +| Near-RT RIC | O-RAN near real time RAN Intelligent Controller | +| NFO | Network Function Orchestration | +| NFV | Network Function Virtualization | +| NFVI | Network Function Virtualization Infrastructure | +| NM | Network Manager | +| Non-RT RIC | O-RAN non-real time RAN Intelligent Controller | +| O-CU-CP | O-RAN Central Unit – Control Plane. | +| O-CU-UP | O-RAN Central Unit – User Plane | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| PCP | Port Control Protocol | +| PK | Primary Key | +| PNF | Physical Network Function | +| RAN | Radio Access Network | +| SDLC | Software Development LifeCycle | +| SMO | Service Management and Orchestration | +| VNF | Virtualized Network Function | +| VPN | Virtual Private Network | +| UPNP | Universal Plug-N-Play | + +# Chapter 2. O-RAN Overview + +## 2.1 Scope and Objectives + +O-RAN activities are guided by the following objectives [11]: + +- Leading the industry towards open, interoperable interfaces, RAN virtualization, and big data and AI enabled RAN intelligence. +- Maximizing the use of common-off-the-shelf hardware and merchant silicon and minimizing proprietary hardware +- Specifying APIs and interfaces, driving standards to adopt them as appropriate, and exploring open source where appropriate + +The O-RAN OAM Architecture identifies management services, managed functions and managed elements supported in O-RAN, including the interworking between service management and orchestration and other O-RAN components such as infrastructure management. Requirements are derived from end-to-end OAM use cases, initially using the initial provisioning of O-RAN service across VNFs and PNFs as the primary use case. The architecture identifies the interfaces between O-RAN Service Management and Orchestration and Managed Elements for different models and example deployment options. It provides a description of the LifeCycle Management for applications delivered from a Solution Provider to a Service Provider/Network Operator. + +Future versions of the architecture will address additional areas of O-RAN OAM functionality. + +## 2.2 End to End OAM Use Cases + +This section contains end to end OAM use cases that O-RAN is expected to support. Requirements will be derived from the use cases. + +The initial use cases defined include O-RAN Service Provisioning and Data Collection. Additional Use Cases will be added as prioritized by the O-RAN community in future versions of this document + +### 2.2.1 O-RAN Service Provisioning + +#### 2.2.1.1 Basic Objective + +In the O-RAN architecture, the radio side includes Near-RT RIC, O-CU-CP, O-CU-UP, O-DU, and O-RU Managed Functions, and the management side is comprised of the Service Management and Orchestration Framework (including the Non-RT RIC). In the NFV environment, O-RAN network elements can also be implemented in a virtualized form, and thus include an Infrastructure layer (e.g. COTS/White Box/Peripheral hardware and virtualization layer) based on an O-Cloud. + +The current use case focuses on network/element deployment rather than physical construction. According to the radio coverage requirement, operators could deploy the O-RAN network/element on dedicated physical resources and/or virtualized resources in a specific area. + +This use case assumes that the network elements are deployed based on an example Network Design using VNFs for centralized functions and PNFs for functions closer to the customer, so that the sequence calls for deployment of VNFs for the Near-RT RIC, O-CU-CP and O-CU-UP first followed by PNFs for the O-DU and O-RU. Note: RF functions must always be realized as PNFs but the O-DU can be realized as a PNF or VNF; this document uses PNF as an example to illustrate the associated OAM flows. + +It is also assumed that secure network connectivity is already available between RAN components. + +#### 2.2.1.2 Entities/Resources involved + +To support the O-RAN network provisioning, the Service Management and Orchestration Framework needs to support the following capabilities: + +- O-RAN network element deployed in selected area + - a) For non-virtualized parts, the Service Management and Orchestration Framework supports the deployment of physical network elements on the target dedicated physical resources which satisfy the coverage requirements, with management through the O1 interface. + - b) For virtualized network elements, the Service Management and Orchestration Framework has the capability to interact with the O-Cloud to perform network element life cycle management, e.g. instantiate the virtualized network element on the target infrastructure through the O2 interface (e.g., indicate the selected geo-location for each VNF to be instantiated, where close to the PNFs). + - c) The Service Management and Orchestration Framework has the capability to consume the provisioning management service through the O1 interface to manage the configuration of the network element, details are defined in O-RAN.WG1.OAM Interface Specification [13]. +- O-RAN network provisioning + - a) Based on the deployed network elements, the Service Management and Orchestration Framework configures the IP addressing, etc. in the PNFs and VNFs to support connectivity between them (this operation could also be performed during the instantiation steps). + - b) Operators can operate and maintain the network dynamically through the O1 and/or O2 interface by means of: + - i. Reconfiguration of the network elements + - ii. System update (usually refers to software management, without adding network elements) and system upgrade (the network elements could be added/removed/modified) + +According to above, the Service Management and Orchestration Framework together with the O-Cloud implements the O-RAN network element deployment and provisioning, creating an O-RAN network to provide service to consumers. + +#### 2.2.1.3 Solutions + +Table 2.2.1-1 shows the O-RAN service provisioning procedures. + +**Table 2.2.1-1: O-RAN service provisioning** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | O-RAN service provisioning | | +| Actors and Roles | [1]. Service Management and Orchestration Framework: NFO, OAM Functions, Non-RT RIC
[2]. O-Cloud: DMS
[3]. PNF
[4]. VNF | | +| Assumptions | | | +| Pre-conditions | [1]. The Service Management and Orchestration Framework and O-Cloud are connected and interact normally
[2]. O-Cloud supports platform and resource management normally
[3]. The PNF was constructed/installed but not activated
[4]. The VNF Software Package has been uploaded to the O-Cloud
[5]. Secure network connectivity is already available between RAN components
- Note: security related procedure is FFS | | +| Begins when | The network operator/manager decides to deploy an O-RAN network in specific geo-location | | +| Step 1 (M) | The service designer deploys Service Model and Artifacts to SMO | | +| Step 2 (M) | SMO on boarding the VNF Descriptors for the service to the O-Cloud | | +| Step 3 (M) | The radio planner orders RAN Service Deployment | | +| Step 4 (M) | The SMO initiates the O-RAN Service instantiation | | +| Step 5 (M) | The SMO interacts with O-Cloud to instantiate Near-RT RIC based on Near-RT RIC VNFD | | +| Step 6 (M) | The O-Cloud creates VNF of Near-RT RIC | | +| Step 7 (M) | The O-Cloud notifies the SMO the Near-RT RIC has been instantiated and SMO updates its inventory | | +| Step 8 (M) | The SMO configures the Near-RT RIC | | +| Step 9 (M) | the O-Cloud creates VNF of O-CU-CP | | +| Step 10 (M) | The O-Cloud notifies the SMO the O-CU-CP has been instantiated and SMO updates its inventory | | +| Step 11 (M) | The SMO prepares configuration, e.g. Near-RT RIC related | | +| Step 12 (M) | The SMO configures the O-CU-CP | | +| Step 13 (M) | The SMO interacts with O-Cloud to instantiate O-CU-UP, for multiple O-CU-UP VNF, the step 13 to 17 is circulated | | +| Step 14 (M) | the O-Cloud creates VNF of O-CU-UP | | +| Step 15 (M) | The O-Cloud notifies the SMO the O-CU-UP has been instantiated and SMO updates its inventory | | +| Step 16 (M) | The SMO prepares configuration, e.g. Near-RT RIC, O-CU-CP related | | +| Step 17 (M) | The SMO configures the O-CU-UP | | +| Step 18 (O) | The SMO deploys xApp to Near-RT RIC | | +| Step 19 (O) | After the above steps the Near-RT RIC could interact with O-CU-CP via E2 interface | | +| Step 20 (O) | After the above steps the Near-RT RIC could interact with O-CU-UP via E2 interface | | +| Step 21 (M) | SMO adds O-DU into inventory, e.g. with an O-DU.ID for each O-DU. For multiple O-DU this step is circulated | | +| Step 22 (M) | SMO add O-RU into inventory in the O-DU record, e.g. with an O-RU.ID for each O-RU. For multiple O-DU this step is circulated | | +| Step 23 (M) | The field technician powers on the O-DU | | +| Step 24 (M) | The O-DU sends Registration to the SMO
Note: controller address determined as per O-RAN-WG1.O1 Interface Specification | | +| Step 25 (M) | The SMO registers the O-DU as on-line | | +| Step 26 (M) | The SMO prepares O-DU configuration, e.g. related information from Near-RT RIC and O-CU-CP, O-CU-UP | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Step 27 (M) | The SMO configures the O-DU
Note: includes NETCONF configuration as per O-RAN WG4.MP.0-v01.00 [12] | | +| Step 28 (O) | The SMO could deploy xApp to O-DU | | +| Step 29 (O) | After the above steps the Near-RT RIC could interact with O-DU via E2 interface | | +| Step 30 (M) | The field technician powers on the O-RU | | +| Step 31 (M) | The O-RU registers to the O-DU
Note: detailed procedures as per O-RAN WG4.MP.0-v01.00 – additional actions for hybrid case not shown | | +| Step 32 (M) | The O-DU sends Config Change Notification to the SMO indicating O-RU on-line | | +| Step 33 (M) | The SMO registers the O-RU as on-line | | +| Step 34 (M) | The SMO configures the O-RU via O-DU | | +| Step 35 (M) | The O-DU gets O-RU configuration information from the SMO | | +| Step 36 (M) | The O-DU configures the O-RU | | +| Step 37 (M) | O-RU sends Registration to the SMO
Note: procedure not currently supported in WG4.MP.0-v01.00 but details assumed as per O-RAN-WG1.O1 Interface Specification | | +| Step 38 (M) | The SMO registers the O-RU as on-line | | +| Step 39 (M) | The SMO prepares O-RU configuration, e.g. include co-related O-DU, etc. | | +| Step 40 (M) | The SMO configures the O-RU | | +| Ends when | All O-RAN network functions needed for service have been registered and configured; SMO holds current inventory of all O-RAN network functions | | +| Exceptions | Not applicable | | +| Post Conditions | The O-RAN network has been established and can provide service to customers | | +| Traceability | REQ-M&O-FUN1, REQ-M&O-FUN2, REQ-M&O-FUN3, REQ-M&O-FUN4, REQ-M&O-FUN5, REQ-M&O-FUN6, REQ-M&O-FUN9, REQ-M&O-FUN10 | | + +![Sequence diagram for O-RAN Service Deployment and Virtualized Part Instantiation and Configuration.](ceed3363e355a3606fb80b028aee05b3_img.jpg) + +The diagram illustrates the O-RAN Service Deployment and Virtualized Part Instantiation and Configuration process, involving Personnel, Service Management & Orchestration Framework, O-Cloud, and O-RAN Components. + +**Personnel:** Service Designer, Radio Planner, Field Technician. + +**Service Management & Orchestration Framework:** NFO, OAM Functions, Non-RT RIC, DMS. + +**O-Cloud:** DMS. + +**O-RAN Components:** Near-RT RIC, O-CU-CP, O-CU-UP. + +**Process Flow:** + +- 1 Deploy Service Model and Artifacts +- 2 On boarding the VNF Descriptors for the service +- 3 Order RAN Service Deployment +- 4 Instantiate (O-RAN Service) +- 5 Instantiate (Near-RT RIC\_VNF) +- 6 Create VNF (Near-RT RIC) +- 7 Notify Near-RT RIC instantiated +- 8 Configure (Near-RT RIC\_Config) +- 9 Create VNF (O-CU-CP) +- 10 Notify O-CU-CP instantiated +- 11 CP\_Cfg = Build (Near-RT RIC\_Cfg) +- 12 Configure (O-CU-CP\_Config) +- Instantiate all req'd O-CU-UP for this O-CU-CP +- 13 Instantiate (O-CU-UP\_VNF) +- 14 Create VNF (O-CU-UP) +- 15 Notify O-CU-UP instantiated +- 16 UP\_Cfg = Build (Near-RT RIC\_cfg, O-CU-CP\_Cfg) +- 17 Configure (O-CU-UP\_Cfg) +- 18 deploy xApps +- Near-RT RIC can't subscribe to O-CU-CP/UP msgs until they exist +- 19 <> Subscribe (Near-RT RIC subscribes to O-CU-CP) +- 20 <> Subscribe (Near-RT RIC subscribes to O-CU-UP) +- Create all PNF Inventory placeholders +- 21 Inventory\_Add (PNF, O-DU, O-DU.ID) +- 22 Inventory\_Add (PNF, O-RU, O-RU.ID) + +Sequence diagram for O-RAN Service Deployment and Virtualized Part Instantiation and Configuration. + +![Sequence diagram for O-RAN Service Provisioning showing interactions between Personnel, Service Management & Orchestration Framework, O-Cloud, and O-RAN Components.](4f10155f97ab961ef9e5ca17b4ec89c8_img.jpg) + +The diagram illustrates the O-RAN Service Provisioning process, divided into two main phases: PNF Registration and Configuration, and O-RU Registration and Configuration. + +**PNF Registration and Configuration:** + +- 23 Poweron:** Initiated by Personnel (Service Designer, Radio Planner, Field Technician) to the O-DU. +- 24 Register O-DU (ID):** O-DU sends its ID to the Non-RT RIC. +- 25 Register PNF Online:** Non-RT RIC sends a registration message to the OAM Functions. +- 26 DU\_Cfg = Generate (Near-RT RIC\_Cfg, O-CU-CP\_Cfg, O-CU-UP):** OAM Functions generate configuration data. +- 27 Configure (O-DU\_Cfg):** OAM Functions send configuration data to the O-DU. +- 28 Configure xAPPs for O-DU:** Non-RT RIC sends configuration data to the O-DU. +- 29 <> Subscribe:** Near-RT RIC subscribes to O-DU messages. +- 30 Poweron:** Initiated by Personnel to the O-RU. + +**O-RU Registration and Configuration:** + +- 31 Register:** O-RU sends its ID to the Non-RT RIC. +- 32 Config Change Notification: O-RU Online (O-RU.ID):** Non-RT RIC sends a notification to the OAM Functions. +- 33 Register PNF Online:** OAM Functions send a registration message to the Non-RT RIC. +- 34 O-DU Configure O-RU (RU.ID, SMO\_RUConfig):** Non-RT RIC sends configuration data to the O-DU. +- 35 O-RUConfig = Merge (O-DU.Config, SMO\_O-RUConfig):** OAM Functions merge configuration data. +- 36 RI Configure (O-RUConfig):** OAM Functions send configuration data to the O-RU. +- 37 Register O-RU (RU.ID):** O-RU sends its ID to the Non-RT RIC. +- 38 Register PNF Online:** Non-RT RIC sends a registration message to the OAM Functions. +- 39 O-RU\_Config = Build (RU[id].Cfg, O-DU\_Cfg):** OAM Functions build configuration data. +- 40 Configure (O-RU\_Config):** OAM Functions send configuration data to the O-RU. + +**Key Components and Data:** + +- Personnel:** Service Designer, Radio Planner, Field Technician. +- Service Management & Orchestration Framework:** NFO, OAM Functions, Non-RT RIC. +- O-Cloud:** DMS. +- O-RAN Components:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU, O-RU. + +Sequence diagram for O-RAN Service Provisioning showing interactions between Personnel, Service Management & Orchestration Framework, O-Cloud, and O-RAN Components. + +Figure 2.2.1-1: O-RAN Service Provisioning + +### 2.2.2 O-RAN Measurement Data Collection + +#### 2.2.2.1 Basic Objective + +In this use case, the Non-RT RIC as the intelligent management center located in Service Management and Orchestration Framework determines that measurement data is needed and interacts with the SMO OAM Functions to collect measurement data from network for AI/ML training/inference/analyzing, and then generate optimization operations in order to improve the end-to-end user service experience and the network performance. + +According to the Service Management and Orchestration Framework, to fulfill the Non-RT RIC requested data collection, the following capability should be supported by the SMO (framework): + +- i The SMO should support the MnS component Type A (defined in [6]) generation and the corresponding operation performing (defined in [5] and [7]), according to the measurement data collection request from the Non-RT RIC +- ii The SMO (framework) should support the MnS component type C (defined in [6]) consumption such as the measurement data requested by the Non-RT RIC + +The current use case focuses on the Non-RT RIC requested measurement data collection and consumption, the SMO should generate the PM Job and perform the PM Job control operations accordingly, and the SMO (framework) should support the measurement data consumption by the Non-RT RIC. + +Notes: + +- i In the O-RAN SMO framework, in order to avoid the PM Job confliction, it is suggested that the SMO take the responsibility for generating the PM Job and performing the PM Job control related operations. The resolution of conflict resolving by the SMO is FFS. +- ii In this use case, the network elements decide if the PM Job is acceptable or not, in other words, it is ultimately the network element (MnS producer) who decides whether the measurement data collection task can be established or not. +- iii Specifications for collecting infrastructure measurements do not yet exist. The Measurement Data Collection procedures will be updated to comply with [15] once WG6 has published the specification. +- iv The measurement data producer in the use case so far doesn't refer to Network Slicing, but this will be added in the use case once the O-RAN network slice has been defined. + +#### 2.2.2.2 Entities/Resources involved + +- Roles in the PM Job Control related operations: + +- a). The Non-RT RIC: PM Job initiator +- b). The SMO (framework): measurement service component type A consumer + +To fulfill the Non-RT RIC requested measurement data collection by the SMO on the O1/O2 interface, the information related to the collection task should comply with section 2.3 defined in [13]. + +The measurement data collection information provided by the Non-RT RIC should be converted into a PM Job, and any management operations to the data collection task requested by the Non-RT RIC should be converted into the O1/O2 interface supported PM Job control related management service operations by the SMO. + +- Roles in the NotifyFileReady subscribing: + +- a). SMO: management service component type A consumer (the referenceConsumer, defined in [5]) +- b). O-RAN MOs: Notification producer + +- Roles in the measurement data consumption: + +- a). SMO: management service component type C consumer +- b). O-RAN MOs: streaming data producer +- c). File Server: storage the measurement data file + +#### 2.2.2.3 Solutions + +##### 2.2.2.3.1 Measurement Data Collection Creation + +Table 2.2.2-1 shows the procedure of the Non-RT RIC requested measurement data collection task fulfilled by the SMO on the O1/O2 interface. + +**Table 2.2.2-1: Measurement Data Collection Creation** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | O-RAN Measurement Data Collection | | +| Actors and Roles | [1]. Service Management and Orchestration Framework
[2]. Non-RT RIC
[3]. O-Cloud
[4]. O-RAN components/logical nodes, e.g. O-CU, O-DU, O-RU, Near-RT RIC. | | +| Assumptions | None | | +| Pre-conditions | [1]. The SMO and the Non-RT RIC are connected and interact normally
[2]. O-RAN components are in normal running status
[3]. Secure network connectivity is already available between RAN components
- Note: security related procedure is FFS | | +| Begins when | The Non-RT RIC determines that it needs measurement data from the O-RAN MOs and corresponding infrastructure resources, e.g., O-CU-CP instance and corresponding infrastructure resources | | +| Step 1 (M) | The Non-RT RIC provides the information of the measurement data to the SMO | | +| Step 2 (M) | The SMO generates a PM Job as the Non-RT RIC required | | +| Step 3.1 (M) | The SMO performs PM Job control management to the O-CU-CP via the O1 interface, e.g. Operation createMeasurementJob defined in [7] | | +| Step 3.2 (M) | The SMO performs PM Job control management to the O-Cloud over the O2 interface for the O-CU-CP infrastructure resource instance, e.g. Create PM Job operation defined in clause 7.7.2, [9] | | +| Step 4.1 (M) | The measured O-CU-CP responds to the SMO with the PM Job creation result. The PM Job ID should be contained. | | +| Step 4.2 (M) | The O-Cloud responds to the SMO with the PM Job creation result with the PM Job ID. | | +| Step 5.1 (M) | The SMO subscribes to PM Notifications to the O-CU-CP instance via the O1 interface. The ConsumerReference defined in 7.1.1.3 [5] could be the SMO address | | +| Step 5.2 (M) | The SMO subscribes to O-CU-CP related infrastructure resource instance PM data to the O-Cloud over the O2 interface | | +| Step 6.1 (M) | The O-CU-CP instance provides the result of this operation to the SMO | | +| Step 6.2 (M) | The O-Cloud provides the SMO with the result of the subscription to the O-CU-CP infrastructure resource instance | | +| Step 7 (M) | The SMO provides the result of the measurement data collection establishment to the Non-RT RIC | | +| Ends when | Non-RT RIC has measurement data | | +| Exceptions | FFS | | +| Post Conditions | The Non-RT RIC initiated measurement data collection has been fulfilled by the SMO; the measured O-RAN MOs generate measured data as the PM Job required. The subscription to the File Ready notification has been created successfully | | +| Traceability | REQ-M&O-FUN7 | | + +![Sequence diagram for Measurement Data Collection Creation. The diagram shows interactions between NFO, OAM Functions, Non-RT RIC, DMS, and O-CU-CP. Key steps include: 1. Measurement data collection information, 2. Generate PM Job, 3.1 Operation createMeasurementJob, 3.2 Create PM Job operation, 4.1 Response, 4.2 Response, 5.1 Operation Subscribe to the O-CU-CP, 5.2 Subscription to the O-Cloud, 6.1 Response to Subscribe, 6.2 Response to Subscription, and 7. Measurement data collection creation result.](6b7fecacf715441b907ed4db9dcaef62_img.jpg) + +``` + +sequenceDiagram + participant NFO + participant OAM as OAM Functions + participant Non-RT RIC + participant DMS + participant O-CU-CP + + Note over NFO, OAM, Non-RT RIC: Service Management & Orchestration Framework + Note over DMS: O-Cloud + Note over O-CU-CP: O-RAN Components + + Note over NFO, OAM, Non-RT RIC: Non-RT RIC Request Measurement Data Collection + Note over NFO, OAM, Non-RT RIC: NonRTRIC plans to collect data from O-CU-CP +NonRTRIC provide the measurement data collection information to SMO + OAM-->>Non-RT RIC: 1 Measurement data collection information + + Note over NFO, OAM, Non-RT RIC: SMO Generate PM Job + Note over NFO, OAM, Non-RT RIC: SMO generates PM Job(s) (defined in 3GPP TS28.550 and ETSI GS NFV IFA005) according to the collection requirement + OAM-->>Non-RT RIC: 2 Generate PM Job + + Note over NFO, OAM, Non-RT RIC: SMO Distribute PM Job + Note over NFO, OAM, Non-RT RIC: 3.1 Operation createMeasurementJob + OAM->>DMS: 3.2 Create PM Job operation + Note over DMS: Create Measurement Job reply + DMS-->>OAM: 4.1 Response + OAM-->>Non-RT RIC: 4.2 Response + + Note over NFO, OAM, Non-RT RIC: Operation Subscribe + Note over NFO, OAM, Non-RT RIC: SMO subscribe O-CU-CP PM Notification as Non-RT RIC required + OAM->>DMS: 5.1 Operation Subscribe to the O-CU-CP + Note over DMS: Subscription to the O-Cloud + DMS-->>OAM: 6.1 Response to Subscribe + OAM-->>Non-RT RIC: 6.2 Response to Subscription + + Note over NFO, OAM, Non-RT RIC: SMO Provides Non-RTRIC With the Measurement Data Collection Create Result + Note over NFO, OAM, Non-RT RIC: SMO provides the Non-RT RIC with the result of the measurement data collection according to the received PM Job response + OAM-->>Non-RT RIC: 7 Measurement data collection creation result + +``` + +Sequence diagram for Measurement Data Collection Creation. The diagram shows interactions between NFO, OAM Functions, Non-RT RIC, DMS, and O-CU-CP. Key steps include: 1. Measurement data collection information, 2. Generate PM Job, 3.1 Operation createMeasurementJob, 3.2 Create PM Job operation, 4.1 Response, 4.2 Response, 5.1 Operation Subscribe to the O-CU-CP, 5.2 Subscription to the O-Cloud, 6.1 Response to Subscribe, 6.2 Response to Subscription, and 7. Measurement data collection creation result. + +Figure 2.2.2-1: Measurement Data Collection Creation + +##### 2.2.2.3.2 Measurement Data File Consumption + +With the performance data file reporting method: + +- The measurement data file could be stored in a file server, and the path should be contained in the NotifyFileReady +- Once the measurement data file has been prepared, the O-CU-CP instance shall report the notification NotifyFileReady to the SMO + +Table 2.2.2-2 shows the measurement data file consumption + +**Table 2.2.2-2: Measurement Data File Ready Report** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | O-RAN Measurement Data Collection | | +| Actors and Roles | [1]. Service Management and Orchestration Framework
[2]. Non-RT RIC
[3]. O-Cloud
[4]. O-RAN components/logical nodes, e.g. O-CU, O-DU, O-RU, Near-RT RIC. | | +| Assumptions | None | | +| Pre-conditions | [1]. The SMO and the Non-RT RIC are connected and interact normally
[2]. O-RAN components are in normal running status
[3]. Secure network connectivity is already available between RAN components
- Note: security related procedure is FFS | | +| Begins when | The SMO shall perform the Operation Subscribe to provide the consumer information to the measurement data producer. The producer shall report the NotifyFileReady once the measurement data file has been prepared | | +| Step 1.1 (M) | The O-CU-CP sends the notification NotifyFileReady to the SMO, and it is consumed by the SMO | | +| Step 1.2 (M) | The O-Cloud reports the infrastructure resource measured data file to the SMO | | +| Step 2 (M) | The SMO retrieves the data file from the FileServer, and the collected data is eventually consumed by the Non-RT RIC | | +| Ends when | SMO has collected data | | +| Exceptions | FFS | | +| Post Conditions | The SMO received the notification of NotifyFileReady successfully, the data file eventually consumed by the Non-RT RIC | | +| Traceability | REQ-M&O-FUN7 | | + +![Sequence diagram illustrating Measurement Data File Consumption. The diagram shows three main components: Service Management & Orchestration Framework (SMO), O-Cloud, and O-RAN Components. SMO contains NFO, OAM Functions, and Non-RT RIC. O-Cloud contains DMS. O-RAN Components contain O-CU-CP. The process starts with 'Measurement File Upload To File Server' from SMO to O-Cloud. A note indicates 'the measurement data has been uploaded to an internal FileServer'. Then, 'Notification NotifyFileReady' is sent from O-Cloud to SMO. SMO then sends '1.1 NotifyFileReady' to O-Cloud and '1.2 O-Cloud resource measured data' to Non-RT RIC. Next, 'Measurement Data File Transfer' occurs from O-Cloud to SMO. A note states 'The data file and O-Cloud measured data are eventually consumed by the Non-RT RIC'. Finally, SMO sends '2 Data file retrieval' to Non-RT RIC.](1adeea95f60e02679278c5920c1d2073_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management & Orchestration Framework + participant OCloud as O-Cloud + participant ORAN as O-RAN Components + + SMO->>OCloud: Measurement File Upload To File Server + Note over OCloud: the measurement data has been uploaded to an internal FileServer + OCloud->>SMO: Notification NotifyFileReady + SMO->>OCloud: 1.1 NotifyFileReady + SMO->>NonRT RIC: 1.2 O-Cloud resource measured data + OCloud->>SMO: Measurement Data File Transfer + Note over SMO: The data file and O-Cloud measured data are eventually consumed by the Non-RT RIC + SMO->>NonRT RIC: 2 Data file retrieval + +``` + +Sequence diagram illustrating Measurement Data File Consumption. The diagram shows three main components: Service Management & Orchestration Framework (SMO), O-Cloud, and O-RAN Components. SMO contains NFO, OAM Functions, and Non-RT RIC. O-Cloud contains DMS. O-RAN Components contain O-CU-CP. The process starts with 'Measurement File Upload To File Server' from SMO to O-Cloud. A note indicates 'the measurement data has been uploaded to an internal FileServer'. Then, 'Notification NotifyFileReady' is sent from O-Cloud to SMO. SMO then sends '1.1 NotifyFileReady' to O-Cloud and '1.2 O-Cloud resource measured data' to Non-RT RIC. Next, 'Measurement Data File Transfer' occurs from O-Cloud to SMO. A note states 'The data file and O-Cloud measured data are eventually consumed by the Non-RT RIC'. Finally, SMO sends '2 Data file retrieval' to Non-RT RIC. + +Figure 2.2.2-2: Measurement Data File Consumption + +##### 2.2.2.3.3 Measurement Streaming Data Consumption + +With the streaming reporting method: + +- The consumer related information was taken to the producer in the operation of performance data collection creation. + - The performance data streaming service producer shall establish streaming connection(s) to the consumer, in this use case, the O-CU-CP instance act as the performance data streaming service producer and the SMO as the consumer. + - The O-CU-CP instance shall send measured data on the established connection(s). +- The table 2.2.2-3 shows the streaming connection(s) establishment and streaming data consumption. + +Table 2.2.2-3: Measurement Streaming Data Consumption + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | O-RAN Measurement Data Collection | | +| Actors and Roles | [1]. Service Management and Orchestration Framework
[2]. Non-RT RIC
[3]. O-Cloud
[4]. O-RAN components/logical nodes, e.g. O-CU, O-DU, O-RU, Near-RT RIC. | | +| Assumptions | None | | +| Pre-conditions | [1]. The SMO and the Non-RT RIC are connected and interact normally
[2]. O-RAN components are in normal running status
[3]. Secure network connectivity is already available between RAN components
- Note: security related procedure is FFS | | +| Begins when | The O-CU-CP instance starts streaming connection(s) establishment to the SMO, and reports the measured data as the PM Job required | | +| Step 1 (M) | The O-CU-CP instance interworks with the SMO to establish streaming connection(s). the connection(s) should not be released until the PM Job is stopped | | +| Step 2.1 (M) | The O-CU-CP instance reports the measured data to the SMO as the PM Job required via the streaming connection(s) | | +| Step 2.2 (O) | The O-Cloud reports the infrastructure resource measured data to the SMO | | +| Ends when | SMO receives measured data | | +| Exceptions | FFS | | +| Post Conditions | The streaming connection(s) has been established between the O-CU-CP instance and the SMO successfully.
The SMO consumed the measured data successfully | | +| Traceability | REQ-M&O-FUN7 | | + +1 + +![Sequence diagram illustrating the O-RAN Measurement Data Collection process. The diagram shows three main lifelines: Service Management & Orchestration Framework (SMO), O-Cloud, and O-RAN Components. The SMO lifeline includes NFO, OAM Functions, and Non-RT RIC. The O-Cloud lifeline includes DMS. The O-RAN Components lifeline includes O-CU-CP. The process starts with 'SMO subscribe O-CU-CP PM Notification as Non-RT RIC required'. This is followed by 'Streaming Connection(s) Establishment', where '1 Streaming Connection(s) established successfully' is reported. Then 'Measurement Data Reporting' occurs, with '2.1 The O-CU-CP reports measured data via streaming connection' and '2.2 The O-Cloud reports the infrastructure resource measured data'. Finally, 'Measurement Data Consumption' occurs, where 'The streaming measurement data is immediately transferred to the Non-RT RIC and is correlated with O-Cloud measured data'.](fa5442e7947b5f35e47ee6ea42cc9434_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management & Orchestration Framework + participant OCloud as O-Cloud + participant ORAN as O-RAN Components + + Note over SMO: NFO, OAM Functions, Non-RT RIC + Note over OCloud: DMS + Note over ORAN: O-CU-CP + + SMO->>ORAN: SMO subscribe O-CU-CP PM Notification as Non-RT RIC required + + Note over SMO, OCloud, ORAN: Streaming Connection(s) Establishment + ORAN->>SMO: 1 Streaming Connection(s) established successfully + + Note over SMO, OCloud, ORAN: Measurement Data Reporting + ORAN->>SMO: 2.1 The O-CU-CP reports measured data via streaming connection + OCloud->>SMO: 2.2 The O-Cloud reports the infrastructure resource measured data + + Note over SMO, OCloud, ORAN: Measurement Data Consumption + Note over SMO: The streaming measurement data is immediately transferred to the Non-RT RIC and is correlated with O-Cloud measured data + +``` + +Sequence diagram illustrating the O-RAN Measurement Data Collection process. The diagram shows three main lifelines: Service Management & Orchestration Framework (SMO), O-Cloud, and O-RAN Components. The SMO lifeline includes NFO, OAM Functions, and Non-RT RIC. The O-Cloud lifeline includes DMS. The O-RAN Components lifeline includes O-CU-CP. The process starts with 'SMO subscribe O-CU-CP PM Notification as Non-RT RIC required'. This is followed by 'Streaming Connection(s) Establishment', where '1 Streaming Connection(s) established successfully' is reported. Then 'Measurement Data Reporting' occurs, with '2.1 The O-CU-CP reports measured data via streaming connection' and '2.2 The O-Cloud reports the infrastructure resource measured data'. Finally, 'Measurement Data Consumption' occurs, where 'The streaming measurement data is immediately transferred to the Non-RT RIC and is correlated with O-Cloud measured data'. + +2 + +3 + +1 +2 +3 + +###### Figure 2.2.2-3: Measurement Streaming Data Consumption + +# Chapter 3. OAM Architecture + +## 3.1 Architectural Principles + +The following section provides architecture principals guiding the support of OAM in the O-RAN architecture. Common OAM functions should be supported through a common set of OAM interface protocols across the different components of the O-RAN architecture + +Management Services should, to the degree possible, align with existing standards specifications: + +- 3GPP 5G Specifications for management interfaces +- ETSI NFV Specifications for life cycle management +- O-RAN WG4.MP.0-v01.00 (Future enhancements to align to 3GPP can be considered.) + +O-RAN OAM specifications should refer to the 3GPP and ETSI specs and not replicate them here. O-RAN OAM specifications must identify needed extensions to support O-RAN and exceptions which cannot be supported. It is the goal of O-RAN to drive any needed extensions into standards to maintain alignment between O-RAN and existing standards. + +## 3.2 Architecture Requirements + +Defines the Architecture requirements applicable to the O-RAN reference architecture. Architecture requirements are derived from Use Cases to be supported and define the functional needs the architecture aims to satisfy. + +The initial set of requirements in this document are derived from the O-RAN Service Provisioning Use Case. More requirements may be added in future versions of the OAM Architecture. + +### 3.2.1 Functional Requirements + +| REQ | Description | Note | +|----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------| +| [REQ-M&O-FUN1] | O-RAN OAM Architecture must support the interaction between the Service Management and Orchestration Framework and the O-Cloud through O2 interface to perform virtualized resource orchestration. | Use Case | +| [REQ-M&O-FUN2] | O-RAN OAM Architecture must support the capability for the Service Management and Orchestration Framework to consume the provisioning management service exposed by each O-RAN managed element, whether implemented as PNF or VNF, through the O1 interface. | O-RAN-WG1.OAM Interface Specification [13] | +| [REQ-M&O-FUN3] | O-RAN OAM Architecture must support creation, modification and termination of VNFs in an O-RAN network by the Service Management and Orchestration Framework | Use Case | +| [REQ-M&O-FUN4] | O-RAN OAM Architecture must support registration and inventory of newly activated VNFs and PNFs by the Service Management and Orchestration Framework | Use Case | +| [REQ-M&O-FUN5] | O-RAN OAM Architecture must support collection of status change and other indications from VNFs and PNFs by the Service Management and Orchestration Framework | Use Case | +| [REQ-M&O-FUN6] | O-RAN OAM Architecture must support configuration of VNFs and PNFs by the Service Management and Orchestration Framework, including, for example, addressing information needed to allow them to connect to each | Use Case | + +| | | | +|-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------| +| | other | | +| [REQ-M&O-FUN7] | O-RAN OAM Architecture must support management of PM jobs, PM data collection/storage/query/statistical reports from O-RAN Components | Use Case | +| [REQ-M&O-FUN8] | O-RAN OAM Architecture must support operation logging and operation authority of Managed Elements | Use Case to be added | +| [REQ-M&O-FUN9] | O-RAN OAM Architecture must support management of Managed Functions contained within a Managed Element | ETSI 3GPP TS 28.622 | +| [REQ-M&O-FUN10] | O-RAN OAM Architecture must support hierarchical and hybrid management of O-RAN O-DU and O-RU components as defined in O-RAN-WG4.MP.0-v01.00 | Use Case & O-RAN MP Spec [12] | +| [REQ-M&O-FUN11] | O-RAN OAM Architecture and interfaces must support network slicing, where an instance of O-RAN managed function may be associated with one or more slices. | Use Case to be added | +| [REQ-M&O-FUN12] | O-RAN OAM Architecture must support O1 interface for all Managed Elements (with the exception of the RU) even if the Managed Element is deployed behind a NAT | O-RAN-WG1.OAM Interface Specification [13] | + +### 3.2.2 Non-Functional Requirements + +| | | | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------| +| [REQ-M&O-NFUN1] | O-RAN OAM Architecture must support the introduction of new and more cost-effective technologies into the RAN through open, standard interfaces | O-RAN white paper [11] | +| [REQ-M&O-NFUN2] | O-RAN OAM Architecture must support virtualization of RAN components, allowing operators use of common, off-the-shelf hardware implementations | O-RAN white paper [11] | +| [REQ-M&O-NFUN3] | O-RAN OAM Architecture must support use of Analytics and Artificial Intelligence/Machine Learning to improve network efficiency and performance and reduce operations costs | O-RAN white paper [11] | + +### 3.2.3 Security Requirements + +| | | | +|-----------------|---------------------------------------------------------------------------------------------------------|----------| +| [REQ-M&O-NFUN4] | O-RAN OAM Architecture must support security of interactions between the components of an O-RAN network | See note | +|-----------------|---------------------------------------------------------------------------------------------------------|----------| + +Note: more detailed requirements for security will be addressed in future versions of the OAM Architecture. + +## 3.3 Reference Architecture + +The reference architecture defines a set of basic architectural building blocks – management services, managed functions and managed elements – for the O-RAN management domain. + +### 3.3.1 Architectural Building Blocks + +#### 3.3.1.1 Management Services + +O-RAN Management Services offer capabilities to manage and orchestrate managed elements. Managed elements expose their management services to managers. Managers consume the management services. + +Examples of Management Services supported by O-RAN include: + +- Provisioning +- Fault Supervision +- Performance Assurance +- Trace Management +- File Management +- Software Management +- Communication Surveillance +- Startup and Registration of a Physical Network Function (PNF) +- Instantiation and Termination of a Virtualized Network Function (VNF) +- Scaling Management Services for VNF + +The definition of supported management services and their APIs will be covered in the OAM O1 Interface specification [13]. + +#### 3.3.1.2 Managed Elements + +The definition of a Managed Element (ME) is given in 3GPP TS 28.622 [3] section 4.3.3. The ME is an IOC that supports communication over management interface(s) to the manager for purposes of control and monitoring. + +Examples of O-RAN Managed Elements include: + +- O-RAN Managed Functions deployed individually as MEs (e.g., Near-RT RIC ME, CU-CP ME, CU-UP ME, O-DU ME, O-RU ME). +- Central Unit (CU) composed of CU-CP and CU-UP +- ME composed of Near-RT RIC, CU-CP, CU-UP, DU and RU + +A variety of deployment examples and their OAM interfaces are given in a later section. Choice of deployment options will be based on operator requirements. + +A key motivation for the Managed Element concept is that an ME is a tightly integrated and tested group of MFs that are deployed together. This has implications on how software updates are managed, because all software updates need to retain the property that all MFs in the ME have been tested together. Depending on the deployment scenario and other considerations, the MFs may be grouped in different ways. An interface is required to each ME, which can manage the communications to each MF that is contained within it. Following sections present many examples of how the O1 interface can connect to either an ME that contains an individual MF, or to an integrated ME that contains multiple MFs. + +#### 3.3.1.3 Managed Functions + +The definition of a Managed Function (MF) is given in 3GPP TS 28.622 [3] section 4.3.4. An MF instance is managed using the management interface(s) exposed by its containing ME instance. + +O-RAN managed functions include: + +- Near-Real-Time Radio Intelligent Controller (Near-RT RIC) +- O-RAN Central Unit – Control Plane (O-CU-CP) +- O-RAN Central Unit – User Plane (O-CU-UP) +- O-RAN Distributed Unit (O-DU) + +- O-RAN Radio Unit (O-RU) + +#### 3.3.1.4 Managed Applications + +*ManagedApplication*: This Information Object Class (IOC) represents a software application that may be independently tested and separately deployed from its containing *ManagedFunction* instance. The containing *ManagedFunction* instance mediates the management service for the Managed Application. A *ManagedFunction* instance may have zero or more Managed Application instances. + +The xApp is defined in [19]. Management of the xApp shall comply with the following principles: + +- The O1 interface terminates on the Near-RT RIC platform ME, the Near-RT RIC platform delegates the management of xApps +- xApp could be provided by the third party, it is decoupled from the O-RAN nodes, O-RAN node supports one or more xApp running on it +- In order to model a variety of different types of xApps, it is necessary to extend common features of a parent Class, and the specific xApp IOC could inherit from its parent Class. + +According to above principles, the modeling to the xApp could be described as the following: + +- xApp IOC represents the management aspects of the xApp +- xApp IOC inherits from *ManagedApplication* and could extend specific attributes. + +The details of the *MA* will be defined in the O-RAN Information Model document [23]. + +#### 3.3.1.5 Service Management and Orchestration Framework + +Service Management and Orchestration Framework is responsible for the management and orchestration of the managed elements under its span of control. The framework can for example be a third-party Network Management System (NMS) or orchestration platform. + +Service Management and Orchestration Framework must provide an integration fabric and data services for the managed functions. The integration fabric enables interoperation and communication between managed functions within the O-RAN domain. Data services provide efficient data collection, storage and movement capabilities for the managed functions. In order to implement multiple OAM architecture options together with RAN service modeling, the modeling of different OAM deployment options and OAM services (integration fabric etc.) must be supported by SMO + +#### 3.3.1.6 Non-Real Time Radio Intelligent Controller + +The non-RT RIC is a part of the Service Management & Orchestration Framework and communicates to the near-RT RIC using the A1 interface. [11] + +Non-RT control functionality ( $> 1\text{s}$ ) and near-Real Time (near-RT) control functions ( $< 1\text{s}$ ) are decoupled in the RIC. Non-RT functions include service and policy management, RAN analytics and model-training for some of the near-RT RIC functionality, and non-RT RIC optimization. + +#### 3.3.1.7 Control Loop Support + +O-RAN defines 3 control loops with different latency bands [11]. It is not expected that these loops are hierarchical but instead run in parallel. This does not mean that an ME with an inner loop will not generate its own event as result of an inner loop failure, but it will not simply propagate the lower level event received by the inner loop. The three loops are roughly defined as: + +- Loop 1: In the DU for per TTI/msec resource scheduling ( $< 10$ millisecond) +- Loop 2: In the Near-RT RIC and CU for resource optimization (10 milliseconds to 1 second) +- Loop 3: In the Service Management and Orchestration Framework for ML Training, Trending, Orchestration ( $> 1$ second) + +### 3.3.2 Basic OAM Architecture + +![Figure 3.3.2-1 O-RAN OAM Logical Architecture diagram. The diagram shows a hierarchical architecture. At the top is the 'Service Management & Orchestration Framework' (purple bar) containing a 'Non-Real Time RIC' (green box). Below this is a dashed line representing the 'Logical OAM Interface'. Underneath is the 'Near-Real Time RAN Intelligent Controller (RIC)' (orange box). To the left of the RIC is an 'O-eNB' (orange box). An orange arrow labeled 'A1' points from the Non-Real Time RIC to the Near-Real Time RIC. Below the RIC is another dashed line. Underneath is a box containing 'O-CU-CP' and 'O-CU-UP' (orange boxes). An orange arrow labeled 'E2' points from the Near-Real Time RIC to the O-CU-CP. A blue double-headed arrow labeled 'E1' connects O-CU-CP and O-CU-UP. To the right of this box is a dashed line labeled 'O1'. Below this is another dashed line. Underneath is a box containing 'O-DU' and 'O-RU' (orange boxes). A blue arrow labeled 'F1-c' points from O-CU-CP to O-DU. A blue arrow labeled 'F1-u' points from O-CU-UP to O-DU. Below this is a dashed line. Underneath is a box containing 'O-Cloud' (green box). A dashed line labeled 'O2' points from the O-Cloud to the O-DU/O-RU box. A legend on the right shows an orange box labeled 'O-RAN Managed Function' and a dashed line labeled 'Logical OAM Interface'.](b8bf649faf1855a088cfce273add9323_img.jpg) + +Figure 3.3.2-1 O-RAN OAM Logical Architecture diagram. The diagram shows a hierarchical architecture. At the top is the 'Service Management & Orchestration Framework' (purple bar) containing a 'Non-Real Time RIC' (green box). Below this is a dashed line representing the 'Logical OAM Interface'. Underneath is the 'Near-Real Time RAN Intelligent Controller (RIC)' (orange box). To the left of the RIC is an 'O-eNB' (orange box). An orange arrow labeled 'A1' points from the Non-Real Time RIC to the Near-Real Time RIC. Below the RIC is another dashed line. Underneath is a box containing 'O-CU-CP' and 'O-CU-UP' (orange boxes). An orange arrow labeled 'E2' points from the Near-Real Time RIC to the O-CU-CP. A blue double-headed arrow labeled 'E1' connects O-CU-CP and O-CU-UP. To the right of this box is a dashed line labeled 'O1'. Below this is another dashed line. Underneath is a box containing 'O-DU' and 'O-RU' (orange boxes). A blue arrow labeled 'F1-c' points from O-CU-CP to O-DU. A blue arrow labeled 'F1-u' points from O-CU-UP to O-DU. Below this is a dashed line. Underneath is a box containing 'O-Cloud' (green box). A dashed line labeled 'O2' points from the O-Cloud to the O-DU/O-RU box. A legend on the right shows an orange box labeled 'O-RAN Managed Function' and a dashed line labeled 'Logical OAM Interface'. + +**Figure 3.3.2-1 O-RAN OAM Logical Architecture** + +Figure 3.3.2-1 shows the overall O-RAN OAM Logical Architecture. In the original white paper [11], the interface between the Manager and the O-RAN components for control purposes was identified as A1. The O-RAN OAM Architecture adds another interface for OAM functions, labeled O1 (OAM). O1 is the interface between the O-RAN Managed Element and the management entity. Note: the figure uses 5G terminology, however the same principles will apply for LTE/4G. Mapping to LTE/4G may be added in future. O-RAN OAM also adds the O2 interface for management of the O-Cloud, which has different requirements from the O1 interface and as defined in [21]. + +The O1 OAM Interface includes implementation of Fault, Configuration, Accounting, Performance, Security (FCAPS) functions, File management and Software management functions to ME (s) virtualized and physical alike. For details of the management services supported by O1, see [13]. + +The O2 OAM Interface enables the management of O-Cloud infrastructures and the deployment life cycle management of O-RAN cloudified NFs that run on an O-Cloud. For details of the functions supported by O2, see [21]. + +As shown in the figure, there is a logical OAM interface to individual O-RAN Managed Functions, however in practice the grouping of Managed Functions into Managed Elements will determine where actual O1 interfaces are terminated. More detail is explained in subsequent sections. The O1 interface could be the terminated directly on the Service Management & Orchestration Framework or in a hierarchical model could be terminated on a Managed Element which manages other O-RAN Managed Functions. + +The sections below identify possible management topologies, for example, the basic “flat” model of OAM relationships as well as the hierarchical model of O-DU to O-RU relationship and the hybrid model of O-DU to O-RU relationship defined in the O-RAN Front Haul M-Plane specification, as well as example deployment options. + +### 3.3.3 OAM Models and Deployment Options + +This section provides examples of possible models and deployments of Managed Functions into Managed Elements. Adoption of a single model is not required in the O-RAN OAM Architecture, rather multiple model deployments may be supported in a network. + +#### 3.3.3.1 Flat Management Architecture Model + +![Figure 3.3.3-1: Flat Model architecture diagram. The diagram shows a Service Management & Orchestration Framework at the top, containing a Non-Real Time RIC. Below this, an O-eNB connects to a Near-Real Time RAN Intelligent Controller (RIC) via interface A1. The RIC connects to O-CU-CP via interface E2. O-CU-CP and O-CU-UP are connected via interface E1. O-CU-CP connects to O-DU via interface F1-c, and O-CU-UP connects to O-DU via interface F1-u. O-DU connects to O-RU via the Open Fronthaul interface. The O-Cloud is connected to the O-DU via interface O2. The O-Cloud is also connected to the O-RU via the Open Fronthaul M-Plane interface. The O-Cloud is connected to the O-DU via interface O1.](aa21b04a298a324f28bf198cd47e38a1_img.jpg) + +Figure 3.3.3-1: Flat Model architecture diagram. The diagram shows a Service Management & Orchestration Framework at the top, containing a Non-Real Time RIC. Below this, an O-eNB connects to a Near-Real Time RAN Intelligent Controller (RIC) via interface A1. The RIC connects to O-CU-CP via interface E2. O-CU-CP and O-CU-UP are connected via interface E1. O-CU-CP connects to O-DU via interface F1-c, and O-CU-UP connects to O-DU via interface F1-u. O-DU connects to O-RU via the Open Fronthaul interface. The O-Cloud is connected to the O-DU via interface O2. The O-Cloud is also connected to the O-RU via the Open Fronthaul M-Plane interface. The O-Cloud is connected to the O-DU via interface O1. + +**Figure 3.3.3-1: Flat Model** + +In the Flat management model, all the MFs comprising the O-RAN architecture are also MEs and expose an O1 interface to the SMO. Note: The Open Fronthaul M-Plane does not support a flat management model for the O-RU. + +NM/orchestration platforms provide a distributed deployment model of NM functions which allows for greater scaling and lower latency functions than traditional centralized monolithic NM implementations. In this specification, no specific platform is required, however the NM is assumed to have orchestration capabilities. Therefore, deployment of SMOs, analytics, configuration and control functions can be potentially collocated with some of the NEs. This allows for localized processing and localized scaling to handle the expected large number of NEs to be managed. The NM functions can be distributed across the network edge and therefore handle a logically flat architecture. + +#### 3.3.3.2 Hierarchical Management Architecture Model + +Where the distributed NM architecture is not available it may be desirable to deploy a hierarchical management architecture where a higher level ME is used to manage a subnetwork of MEs as shown in Figure 3.3.3-2, where the O-DU manages the O-RU using the Open Front Haul M-Plane interface. + +![Figure 3.3.3-2: Hierarchical Model Example architecture diagram. The diagram shows a Service Management & Orchestration Framework at the top, containing a Non-Real Time RIC. Below this, an O-eNB connects to a Near-Real Time RAN Intelligent Controller (RIC) via interface A1. The RIC connects to O-CU-CP via interface E2. O-CU-CP and O-CU-UP are connected via interface E1. O-CU-CP connects to O-DU via interface F1-c, and O-CU-UP connects to O-DU via interface F1-u. O-DU connects to O-RU via the Open Fronthaul M-Plane interface. The O-Cloud is connected to the O-DU via interface O2. The O-Cloud is also connected to the O-RU via the Open Fronthaul M-Plane interface. The O-Cloud is connected to the O-DU via interface O1.](bf632c49a2d728e3d215e688183d2115_img.jpg) + +Figure 3.3.3-2: Hierarchical Model Example architecture diagram. The diagram shows a Service Management & Orchestration Framework at the top, containing a Non-Real Time RIC. Below this, an O-eNB connects to a Near-Real Time RAN Intelligent Controller (RIC) via interface A1. The RIC connects to O-CU-CP via interface E2. O-CU-CP and O-CU-UP are connected via interface E1. O-CU-CP connects to O-DU via interface F1-c, and O-CU-UP connects to O-DU via interface F1-u. O-DU connects to O-RU via the Open Fronthaul M-Plane interface. The O-Cloud is connected to the O-DU via interface O2. The O-Cloud is also connected to the O-RU via the Open Fronthaul M-Plane interface. The O-Cloud is connected to the O-DU via interface O1. + +**Figure 3.3.3-2: Hierarchical Model Example** + +In the example of the figure 3-3, the O-RU is managed by the Open Fronthaul M-Plane interface to the O-DU rather than the Service Management & Orchestration Framework, so there is a hierarchical relationship between Service + +Management & Orchestration and the O-DU. The O-DU must provide a consistent and standardized view of the subtending O-RUs as specified above. + +#### 3.3.3.3 Hybrid Management Architecture Model + +In the Hybrid management architecture, the O-RU is managed partially by the O-DU and partially by the SMO. + +The management by O-DU is via the Open Fronthaul M-Plane, and the SMO manages the O-RU through a direct interface. Note: The O-RU currently supports hybrid mode using an Open Fronthaul M-Plane logical direct interface defined in the Open Fronthaul M-Plane specification [12] between the O-RU and SMO. This direct interface may be augmented with an O1 Interface at some time in the future, as in [17]. + +![Figure 2.3.3-3: Hybrid Model architecture diagram. The diagram shows a Service Management & Orchestration Framework at the top, containing a Non-Real Time RIC. Below this is the O-eNB. The framework connects to a Near-Real Time RAN Intelligent Controller (RIC) via interface A1. The RIC connects to O-CU-CP and O-CU-UP via interface E2. O-CU-CP and O-CU-UP are connected via interface E1. O-CU-CP connects to O-DU via interface F1-c. O-CU-UP connects to O-DU via interface F1-u. The O-DU is connected to O-RU via the Open Fronthaul M-Plane. The O-RU is connected to O-Cloud via interface O2. The O-DU is also connected to O-Cloud via interface O1.](7d25338b1b3e000c5c51743620ded318_img.jpg) + +Figure 2.3.3-3: Hybrid Model architecture diagram. The diagram shows a Service Management & Orchestration Framework at the top, containing a Non-Real Time RIC. Below this is the O-eNB. The framework connects to a Near-Real Time RAN Intelligent Controller (RIC) via interface A1. The RIC connects to O-CU-CP and O-CU-UP via interface E2. O-CU-CP and O-CU-UP are connected via interface E1. O-CU-CP connects to O-DU via interface F1-c. O-CU-UP connects to O-DU via interface F1-u. The O-DU is connected to O-RU via the Open Fronthaul M-Plane. The O-RU is connected to O-Cloud via interface O2. The O-DU is also connected to O-Cloud via interface O1. + +**Figure 2.3.3-3: Hybrid Model** + +Management responsibility is divided in this case between the O-DU and the Service Management & Orchestration Framework. Open Fronthaul M-Plane interface in the figure is defined in [12]. The O-RU supports connection to multiple clients as well as access control that can be used to control the privileges available to a particular client in Open Fronthaul M-Plane [12]. The alignment between the Open Fronthaul M-Plane and O1 interfaces is for further study. + +#### 3.3.3.4 Example Managed Deployment Options + +In aggregated equipment, the Managed Element contains multiple internal Managed Functions. This section provides a number of examples showing how the OAM architecture is applied to different groupings of Managed Functions into Managed Elements. Use cases associated with different deployment options are defined in [15]. + +Figure 3.3.3-4 shows a single Managed Element that contains CU-CP, CU-UP, O-DU and O-RU Managed Functions. + +![Figure 3.3.3-4: Example with Single Integrated ME. This diagram shows the Service Management & Orchestration Framework (SMA) at the top, containing a Non-Real Time RIC. Below the SMA is a large orange box representing a Managed Element (ME). Inside this ME, there is a Near-Real Time RAN Intelligent Controller (RIC) at the top, which connects to O-CU-CP and O-CU-UP via interface E1. O-CU-CP and O-CU-UP both connect to O-DU via F1-c and F1-u respectively. O-DU connects to O-RU via Open Fronthaul. The entire ME is connected to the O-Cloud via interface O2. A single O1 interface is shown on the right, representing a consistent view of the managed functions within the ME.](bfac6c1518721cc987c75cbc8f9b697d_img.jpg) + +Figure 3.3.3-4: Example with Single Integrated ME. This diagram shows the Service Management & Orchestration Framework (SMA) at the top, containing a Non-Real Time RIC. Below the SMA is a large orange box representing a Managed Element (ME). Inside this ME, there is a Near-Real Time RAN Intelligent Controller (RIC) at the top, which connects to O-CU-CP and O-CU-UP via interface E1. O-CU-CP and O-CU-UP both connect to O-DU via F1-c and F1-u respectively. O-DU connects to O-RU via Open Fronthaul. The entire ME is connected to the O-Cloud via interface O2. A single O1 interface is shown on the right, representing a consistent view of the managed functions within the ME. + +**Figure 3.3.3-4: Example with Single Integrated ME** + +As shown in the figure 3.3.3-4, there is a single O1 interface to the Managed Element. However, the O1 interface still provides a consistent and standardized view of the Managed Functions that are contained within the Managed Element. + +Figure 3.3.3-5 shows another example where the Near-RT RIC has been split off as a standalone ME. + +![Figure 3.3.3-5: Example with Single Integrated ME + Standalone Near-RT RIC. This diagram shows the SMA with a Non-Real Time RIC. Below it, there are two separate Managed Elements (MEs). The first ME is a standalone Near-Real Time RAN Intelligent Controller (RIC) that connects to the SMA via interface A1 and has its own O1 interface. The second ME is a larger orange box containing O-CU-CP, O-CU-UP, O-DU, and O-RU, connected via E1, F1-c, F1-u, and Open Fronthaul respectively. This second ME also has its own O1 interface. Both MEs are connected to the O-Cloud via interface O2.](c1c07bc558389cbdd94f5bb3fc26b49f_img.jpg) + +Figure 3.3.3-5: Example with Single Integrated ME + Standalone Near-RT RIC. This diagram shows the SMA with a Non-Real Time RIC. Below it, there are two separate Managed Elements (MEs). The first ME is a standalone Near-Real Time RAN Intelligent Controller (RIC) that connects to the SMA via interface A1 and has its own O1 interface. The second ME is a larger orange box containing O-CU-CP, O-CU-UP, O-DU, and O-RU, connected via E1, F1-c, F1-u, and Open Fronthaul respectively. This second ME also has its own O1 interface. Both MEs are connected to the O-Cloud via interface O2. + +**Figure 3.3.3-5: Example with Single Integrated ME + Standalone Near-RT RIC** + +In the example of Figure 3.3.3-5, there are separate O1 interfaces supported by each ME. The ME containing the Near-RT RIC Managed Function supports management of only this function through its O1 interface, while the ME containing the other Managed Functions provides a view of all contained functions. + +![Figure 3.3.3-6: Example ME aggregating Near-RT RIC, O-CU-CP and O-CU-UP. The diagram shows a Service Management & Orchestration Framework at the top containing a Non-Real Time RIC. Below it, a Managed Element (ME) is shown as a large orange box. Inside this ME, there is a Near-Real Time RAN Intelligent Controller (RIC) at the top, which connects to O-CU-CP and O-CU-UP via interface E1. O-CU-CP and O-CU-UP both connect to O-DU via interfaces F1-c and F1-u respectively. O-DU connects to O-RU via the Open Fronthaul interface. The ME is connected to the Non-Real Time RIC via interface A1. The ME is also connected to the O-Cloud via interface O2. The ME is labeled O1.](826091f3b1e383141f439bf9c248489e_img.jpg) + +Figure 3.3.3-6: Example ME aggregating Near-RT RIC, O-CU-CP and O-CU-UP. The diagram shows a Service Management & Orchestration Framework at the top containing a Non-Real Time RIC. Below it, a Managed Element (ME) is shown as a large orange box. Inside this ME, there is a Near-Real Time RAN Intelligent Controller (RIC) at the top, which connects to O-CU-CP and O-CU-UP via interface E1. O-CU-CP and O-CU-UP both connect to O-DU via interfaces F1-c and F1-u respectively. O-DU connects to O-RU via the Open Fronthaul interface. The ME is connected to the Non-Real Time RIC via interface A1. The ME is also connected to the O-Cloud via interface O2. The ME is labeled O1. + +**Figure 3.3.3-6: Example ME aggregating Near-RT RIC, O-CU-CP and O-CU-UP** + +Figure 3.3.3-6 shows an alternative example with two Managed Elements containing the Near-RT RIC/O-CU-CP/O-CU-UP, and the O-DU and O-RU Managed Functions, respectively. Again, the O1 interfaces from the MEs provide a consistent and standardized view of the contained Managed Functions. + +![Figure 3.3.3-7: Example with Three MEs. The diagram shows a Service Management & Orchestration Framework at the top containing a Non-Real Time RIC. Below it, three Managed Elements (MEs) are shown as orange boxes. The top ME contains a Near-Real Time RAN Intelligent Controller (RIC) and O-CU-CP. The middle ME contains O-CU-UP. The bottom ME contains O-DU and O-RU. The top ME connects to the Non-Real Time RIC via interface A1. The top ME connects to O-CU-UP via interface E1. O-CU-UP connects to O-DU via interfaces F1-c and F1-u. O-DU connects to O-RU via the Open Fronthaul interface. The top ME is connected to the Non-Real Time RIC via interface O1. The top ME is also connected to the O-Cloud via interface O2. The top ME is labeled O1.](2ae2b95770ac4be81072d7fff4db2153_img.jpg) + +Figure 3.3.3-7: Example with Three MEs. The diagram shows a Service Management & Orchestration Framework at the top containing a Non-Real Time RIC. Below it, three Managed Elements (MEs) are shown as orange boxes. The top ME contains a Near-Real Time RAN Intelligent Controller (RIC) and O-CU-CP. The middle ME contains O-CU-UP. The bottom ME contains O-DU and O-RU. The top ME connects to the Non-Real Time RIC via interface A1. The top ME connects to O-CU-UP via interface E1. O-CU-UP connects to O-DU via interfaces F1-c and F1-u. O-DU connects to O-RU via the Open Fronthaul interface. The top ME is connected to the Non-Real Time RIC via interface O1. The top ME is also connected to the O-Cloud via interface O2. The top ME is labeled O1. + +**Figure 3.3.3-7: Example with Three MEs** + +Figure 3.3.3-7 shows an alternative example with three Managed Elements containing the Near-RT RIC/CU-CP, the CU-UP, and the O-DU and O-RU Managed Functions, respectively. Again, the O1 interfaces from the MEs provide a consistent and standardized view of the contained Managed Functions. + +Finally, Figure 3.3.3-8 shows a similar grouping of Managed Functions, but with the Near-RT RIC separated as its own Managed Element. The same architectural concepts apply. + +![Figure 3.3.3-8: Example with Three MEs including Standalone Near-RT RIC. The diagram shows a Service Management & Orchestration Framework at the top, containing a Non-Real Time RIC. Below it is a Near-Real Time RAN Intelligent Controller (RIC). The RAN is divided into three parts: O-CU-CP, O-CU-UP, and O-DU. The O-DU is connected to an Open Fronthaul, which is connected to O-RU. The O-RU is connected to the O-Cloud. The diagram also shows connections between the Non-Real Time RIC and the Near-Real Time RIC (A1), and between the Near-Real Time RIC and the O-CU-CP (E2). The O-CU-CP and O-CU-UP are connected via E1. The O-CU-CP and O-DU are connected via F1-c, and the O-CU-UP and O-DU are connected via F1-u. The O-DU and O-RU are connected via Open Fronthaul. The O-Cloud is connected to the O-RU. The diagram also shows connections between the Non-Real Time RIC and the O-Cloud (O1), and between the Near-Real Time RIC and the O-Cloud (O2).](ec3dd01aafb74614d8c185d813cd4ae0_img.jpg) + +Figure 3.3.3-8: Example with Three MEs including Standalone Near-RT RIC. The diagram shows a Service Management & Orchestration Framework at the top, containing a Non-Real Time RIC. Below it is a Near-Real Time RAN Intelligent Controller (RIC). The RAN is divided into three parts: O-CU-CP, O-CU-UP, and O-DU. The O-DU is connected to an Open Fronthaul, which is connected to O-RU. The O-RU is connected to the O-Cloud. The diagram also shows connections between the Non-Real Time RIC and the Near-Real Time RIC (A1), and between the Near-Real Time RIC and the O-CU-CP (E2). The O-CU-CP and O-CU-UP are connected via E1. The O-CU-CP and O-DU are connected via F1-c, and the O-CU-UP and O-DU are connected via F1-u. The O-DU and O-RU are connected via Open Fronthaul. The O-Cloud is connected to the O-RU. The diagram also shows connections between the Non-Real Time RIC and the O-Cloud (O1), and between the Near-Real Time RIC and the O-Cloud (O2). + +Figure 3.3.3-8: Example with Three MEs including Standalone Near-RT RIC + +### 3.3.4 Managed Elements Deployed behind a NAT + +Service Providers prefer to not deploy Managed Elements (ME) behind a NAT, but there are cases where this cannot be avoided, for example: + +- exhaustion of public IPv4 addresses +- managed elements deployed in large complexes not owned by the Service Provider (Apartments, Sports Venues etc.) +- managed elements connected via third-party networks using a NAT + +When a Service Provider deploys managed elements behind a NAT it is critical that they are able to retain full management control of these elements. + +![Figure 3.3.4.1 O-RAN MEs behind a NAT. The diagram shows a central Internet cloud (public IP addresses) connected to three other clouds: 'Network with NAT (private IP addresses)' on the left, 'Network owned/managed by Service provider' on the right, and 'Network with NAT (private IP addresses)' at the bottom. Each of these three clouds contains a Firewall icon. The left and bottom clouds also contain icons for Mobile Elements (ME). The right cloud contains icons for ME and a server icon. The Internet cloud is connected to all three other clouds.](9d2074faa6badaafc64c9c09cd1d96f2_img.jpg) + +Figure 3.3.4.1 O-RAN MEs behind a NAT. The diagram shows a central Internet cloud (public IP addresses) connected to three other clouds: 'Network with NAT (private IP addresses)' on the left, 'Network owned/managed by Service provider' on the right, and 'Network with NAT (private IP addresses)' at the bottom. Each of these three clouds contains a Firewall icon. The left and bottom clouds also contain icons for Mobile Elements (ME). The right cloud contains icons for ME and a server icon. The Internet cloud is connected to all three other clouds. + +Figure 3.3.4.1 O-RAN MEs behind a NAT + +Four methods of providing the O-RAN Manager with the ability to address a ME behind a NAT and identify data received from a ME behind a NAT are recommended in priority order: + +1. ME uses IPv6 as Backhaul transport where possible eliminating the need for a NAT - exhaustion of public IPv4 addresses +2. ME establishes persistent VPN tunnel (e.g. IPSec) toward a VPN concentrator (gateway) located outside of network with the NAT. The ME is then accessible through the established tunnel. +3. ME uses a standard protocol (UPNP or PCP) to establish a port-forwarding rule at the firewall and automatically assign itself a port. + +4. Service Provider manually configures the firewall to assign a port to each ME that resides within the protected network. + +# Chapter 4. Application Lifecycle Management (LCM) + +This chapter describes Lifecycle Management of applications that are developed by a Solution Provider and delivered to a Service Provider or Network Operator for deployment in O-RAN. The chapter's current focus is on LCM of rApps and xApps, as defined in [17]. + +Lifecycle Management follows the basic models of a Software Development Lifecycle by defining the transitional information from one state to another. There are several Software Development Life Cycle (SDLC) definitions. For the purposes of discussion this document generally follows a 7-state model as shown in Figure 4-3. Some states might also include activities that align with other states. However, this level of detail is not depicted here in order to introduce those details later in the document. + +![Figure 4-3: Generalized Lifecycle. A circular diagram showing the 7-state model of the Software Development Lifecycle. The states are arranged in a circle: Ideation (grey), Analysis (yellow), Develop (blue), Deliver (green), Validate (orange), Operate (grey), and Needs (orange). Arrows indicate the flow from one state to the next in a clockwise direction. The diagram is divided into two main sections: 'Service Provider' (top half) and 'Solution Provider' (bottom half).](dafc7301db467f8e91f196ad69565e78_img.jpg) + +Figure 4-3: Generalized Lifecycle. A circular diagram showing the 7-state model of the Software Development Lifecycle. The states are arranged in a circle: Ideation (grey), Analysis (yellow), Develop (blue), Deliver (green), Validate (orange), Operate (grey), and Needs (orange). Arrows indicate the flow from one state to the next in a clockwise direction. The diagram is divided into two main sections: 'Service Provider' (top half) and 'Solution Provider' (bottom half). + +A Service Provider or Network Operator has needs which are fulfilled by a Solution Provider. Once the Solution Provider delivers the application it is validated in a test environment prior to giving to operations to deploy. Usage of the deployed application may result in changes to configuration by the Service Provider or may be feedback to Solution Providers to evolve the capabilities of the network and/or its management. + +Although applications may come in many forms the delivery from the Solution Provider to the Service Provider needs to be done in a standardized manner. The seven steps defined in the SDLC are high level. Each may break down into a set of finer grain steps. + +**Figure 4-3: Generalized Lifecycle** + +## 4.1 Scope + +The end-to-end lifecycle involves two entities, the Solution Provider and the Service Provider. The Solution Provider provides applications for the Service Provider to use in their network. The working flow could be summarized as three phases: Development, Onboarding and Operations, as shown in Figure 4.1-4. + +![Figure 4.1-4 Application Lifecycle Phases. A flow diagram showing the three main phases of the application lifecycle: 'App Development', 'App Onboarding', and 'App Operation'. 'App Development' includes Ideation, Analysis, Development, and Delivery. 'App Onboarding' includes Onboarding and Validation. 'App Operation' includes Management and Monitoring. Arrows show the flow from Development to Onboarding (labeled 'App/Model Package') and from Onboarding to Operation (labeled 'App/Model Catalogue'). A feedback loop arrow at the bottom connects the Operation phase back to the Development phase, labeled 'Needs/Sample Data/Feedback/Optimization request'.](c8fcd327fc94ea5df3260fea6137a570_img.jpg) + +Figure 4.1-4 Application Lifecycle Phases. A flow diagram showing the three main phases of the application lifecycle: 'App Development', 'App Onboarding', and 'App Operation'. 'App Development' includes Ideation, Analysis, Development, and Delivery. 'App Onboarding' includes Onboarding and Validation. 'App Operation' includes Management and Monitoring. Arrows show the flow from Development to Onboarding (labeled 'App/Model Package') and from Onboarding to Operation (labeled 'App/Model Catalogue'). A feedback loop arrow at the bottom connects the Operation phase back to the Development phase, labeled 'Needs/Sample Data/Feedback/Optimization request'. + +**Figure 4.1-4 Application Lifecycle Phases** + +These applications need to be onboarded in a common manner, regardless of how they are deployed. This document focuses on the data that must be included in the App Package as it is exchanged between the Solution Provider and the Service Provider. This exchange is referred to as the "SP" exchange. This is not a formal interface between systems and therefore is not denoted as other O-RAN interfaces are. Care is given as not to put implementation or tooling mandates on either the Solution Provider in their development of the application, or the Service Provider in the aspect of training or deploying the application. Aspects of the lifecycle across both parties are introduced. However, not all aspects are discussed. Instead the focus is on those activities that affect the data contained in the SP Exchange. Later in this document the term "Service Planning" is used to represent activities internal to the Service Provider. This is not the + +same as the "SP Exchange" used to describe the data passed from the Solution Provider to the Service Provider. The method of the SP Exchange is not defined in this document. It is sometimes referred to as the "Marketplace". The marketplace can be implemented by either the solution provider, the service provider, and an external entity to both. The Marketplace simply represents an exchange between entities which could be done by electronic means or physical media. + +The App Development will provide application solutions w/wo AI/ML models, while "App Onboard" and "App Operate" will be responsible for application onboarding and operations. Considering the data privacy and security requirements, the application development could be completed in the environment provided by the Service Provider. + +Applications utilize AI/ML models or not. Therefore, although the Model Information may be optional in the package, we will focus on the data exchange requirements for applications with AI/ML models as the superset. + +### 4.1.1 Information Model + +An Entity Relationship Diagram (ERD) is a way to pictorially show relationships and cardinality between "Entities". Entities can be anything, physical, logical, or conceptual. They usually have some attributes to differentiate one instance from another. The entities relationship is identified with a connector which uses symbols at both ends to show the cardinality between the entities. The symbol represents the cardinality of the far end to the entity near the symbol. These basic concepts are shown in Figure 4.1-5 Entity Relationship Diagram Basic ComponentsFigure 4.1-5. Some other notations are fields marked as a Primary Key (PK), a Foreign Key (FK), or an Alternate Key (AK). Numbers may be appended to show when multiple fields are combined to create a unique key value. + +![Figure 4.1-5 Entity Relationship Diagram Basic Components. The diagram shows two entities, Entity 1 and Entity 2, connected by a line. Entity 1 is labeled 'Entity 1' and Entity 2 is labeled 'Entity 2'. The relationship is described as 'Entity 1 has many Entity 2' and 'Entity 2 has one Entity 1'. To the right of the diagram is a legend for cardinality notations: a line with an arrow pointing right is 'Contains one'; a line with a vertical bar and a crossbar is 'One'; a line with a crow's foot symbol is 'Many'; a line with a vertical bar and a double crossbar is 'One (and only one)'; a line with a circle and a vertical bar and a crossbar is 'Zero or one'; a line with a crow's foot and a vertical bar and a crossbar is 'One or many'; a line with a circle and a crow's foot and a vertical bar and a crossbar is 'Zero or many'.](3a5731e56852fbad66c92f17a9d821a5_img.jpg) + +Figure 4.1-5 Entity Relationship Diagram Basic Components. The diagram shows two entities, Entity 1 and Entity 2, connected by a line. Entity 1 is labeled 'Entity 1' and Entity 2 is labeled 'Entity 2'. The relationship is described as 'Entity 1 has many Entity 2' and 'Entity 2 has one Entity 1'. To the right of the diagram is a legend for cardinality notations: a line with an arrow pointing right is 'Contains one'; a line with a vertical bar and a crossbar is 'One'; a line with a crow's foot symbol is 'Many'; a line with a vertical bar and a double crossbar is 'One (and only one)'; a line with a circle and a vertical bar and a crossbar is 'Zero or one'; a line with a crow's foot and a vertical bar and a crossbar is 'One or many'; a line with a circle and a crow's foot and a vertical bar and a crossbar is 'Zero or many'. + +**Figure 4.1-5 Entity Relationship Diagram Basic Components** + +The following ERD diagram illustrates the composition of the **Application Package**. An **Application Package** is the basic unit exchanged between the Solution Provider and Service Provider. The attributes of the entities in the diagram are representative. The actual contents are FFS and will be refined in a later release of this document. + +![Figure 4.1-6 Application Package Entity Relationship Diagram. The diagram shows the relationships between several entities: Metadata, ApplicationPackage, MachineLearningModel, TrainingHistory, DeploymentConfiguration, ApplicationType, DeployableComponent, ComponentModelConfig, AppTypeDeploymentConfig, and DeployableComponentConfig. ApplicationPackage is the central entity, linked to Metadata, MachineLearningModel, TrainingHistory, DeploymentConfiguration, ApplicationType, and DeployableComponent. MachineLearningModel and TrainingHistory are linked to each other. DeploymentConfiguration and ApplicationType are linked to each other. DeployableComponent and ComponentModelConfig are linked to each other. AppTypeDeploymentConfig and DeployableComponentConfig are linked to their respective parent entities, ApplicationType and DeployableComponent.](e1d4ec23982efb28dcd6fda23a2f68a6_img.jpg) + +``` + +erDiagram + Metadata ||--o{ ApplicationPackage : "has" + ApplicationPackage ||--o{ MachineLearningModel : "has" + ApplicationPackage ||--o{ TrainingHistory : "has" + ApplicationPackage ||--o{ DeploymentConfiguration : "has" + ApplicationPackage ||--o{ ApplicationType : "has" + ApplicationPackage ||--o{ DeployableComponent : "has" + MachineLearningModel ||--o{ TrainingHistory : "has" + DeploymentConfiguration ||--o{ ApplicationType : "has" + DeployableComponent ||--o{ ComponentModelConfig : "has" + AppTypeDeploymentConfig ||--o{ ApplicationType : "has" + DeployableComponentConfig ||--o{ DeployableComponent : "has" + +``` + +Figure 4.1-6 Application Package Entity Relationship Diagram. The diagram shows the relationships between several entities: Metadata, ApplicationPackage, MachineLearningModel, TrainingHistory, DeploymentConfiguration, ApplicationType, DeployableComponent, ComponentModelConfig, AppTypeDeploymentConfig, and DeployableComponentConfig. ApplicationPackage is the central entity, linked to Metadata, MachineLearningModel, TrainingHistory, DeploymentConfiguration, ApplicationType, and DeployableComponent. MachineLearningModel and TrainingHistory are linked to each other. DeploymentConfiguration and ApplicationType are linked to each other. DeployableComponent and ComponentModelConfig are linked to each other. AppTypeDeploymentConfig and DeployableComponentConfig are linked to their respective parent entities, ApplicationType and DeployableComponent. + +**Figure 4.1-6 Application Package Entity Relationship Diagram** + +The following modifiers can be pre-pended to Information Model Elements to indicate context: + +**"Solution"** The version of the element as defined by the **Solution Provider** + +**"Onboarded"** The initial version of the catalogued elements created during onboarding. + +**"Catalogue"** Subsequent versions of the catalogued package or its elements which may have been adjusted by the **Service Provider**. + +The **"Application Package"** contains a Metadata repository with metadata files in YAML [21] format. It also contains a security metadata file in YAML format which describes the procedures used for ensuring the integrity of the software contained in the package. + +The **Application Package** also contains repositories for **Deployment Configurations**, **Application Types**, and **Deployable Components**. An optional repository for **ML Models** is supplied for Application Packages with one or more application types employing ML technology. + +ML Models may be pre-trained by the **Solution Provider** and therefore provide initial **Training History**. The **Service Provider** may also train the model or retrain the model with a more specialized data set, this is called **specialization**. The **Training History** provides the mechanism to record all training and subsequent specializations applied to that training through the **Training History**. + +An example of specialization is a **ML Model** created to predict the flow of traffic volumes. This algorithm can be generally trained to follow road patterns for devices with a velocity greater than 20 miles per hour. This training could be done by the **Solution Provider** on a generalized or open data set and recording in the **Solution Training History**. After onboarding the **Service Provider** may provide specialized training for dense urban traffic patterns which don't always follow the roads due to periodic traffic congestion. This would be an additional **Training History** record added by the **Service Provider** and referenced as specialization in the **Catalogue Training History**. Further refinement could also be applied for specific cities such as New York, Los Angeles, or San Francisco which would now add 3 specializations **Catalogue Training History** records relating to the dense urban **Catalogue Training History** which is a specialization if the **Onboarded Training History**. + +Once a **Catalogue Deployment Configuration** is validated as safe for use in operations it is published to a runtime environment as a **Published Deployment Configuration**. Runtime instance data can be applied to the **Published Deployment Configuration**. **Application Types** deployed as part of this activity are called an **App Instance**. An **APP Instance** running in the Non-RT RIC Runtime can be referred to as an **rAPP** instance. An **App Instance** running in the near-RT RIC Runtime can be referred to as an **xApp** instance. An **App Instance** running in a training environment is referred to as a **Training App** instance. + +### 4.1.2 Diagramming Legend + +The legend depicted in Figure 4.1-7 is used across all lifecycle diagrams in this section and is shown once so it is not required on every diagram. Bolded text on a diagram is an item identified as requiring further discussion later in the document. Text in Italics are items identified for completeness but not requiring further discussion. Meet-Me-Points (MMPs) are places where a major aspect of the lifecycle interchanges. Data may be exchanged through these MMPs but the exact mechanism of the exchange is outside the scope of this document. Destination or Decision points are color coded according to their user community. Destination or Decision points are not a contributing factor to the data demands of the "SP" Exchange and are therefore not named. Instead the actions or conditions that are used as a transition between points are named as the items of interest. + +![Figure 4.1-7: Life Cycle Diagram Legend. The legend is divided into two main sections. The left section, titled 'Legend', defines 'Action' as a topic requiring further analysis and 'Condition' as an item out of scope. It also shows 'Meet-Me-Points (MMP)' with 'External MMP' and 'Internal MMP' examples. The right section, titled 'Destination or Decision Points', lists five color-coded lines: Blue Line (App Development Phase), Green Line (App Onboarding Phase), Yellow Line (App Operations [Network] Phase), Purple Line (App Operations [SMO] Phase), and Light Blue Line (App Onboarding Phase (Provider Hosted Training)).](c32d31a80f79e90161732a44b049171e_img.jpg) + +| Legend | | Destination or Decision Points | | +|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--------------------------------|-------------------------------------------------| +| Action – Topic which requires further analysis | | Blue Line – | App Development Phase | +| Condition – Which is out of scope for this document. | | Green Line – | App Onboarding Phase | +| Meet-Me-Points (MMP)
External MMP
Internal MMP
| | Yellow Line – | App Operations [Network] Phase | +| | | Purple Line – | App Operations [SMO] Phase | +| | | Light Blue Line – | App Onboarding Phase (Provider Hosted Training) | + +Figure 4.1-7: Life Cycle Diagram Legend. The legend is divided into two main sections. The left section, titled 'Legend', defines 'Action' as a topic requiring further analysis and 'Condition' as an item out of scope. It also shows 'Meet-Me-Points (MMP)' with 'External MMP' and 'Internal MMP' examples. The right section, titled 'Destination or Decision Points', lists five color-coded lines: Blue Line (App Development Phase), Green Line (App Onboarding Phase), Yellow Line (App Operations [Network] Phase), Purple Line (App Operations [SMO] Phase), and Light Blue Line (App Onboarding Phase (Provider Hosted Training)). + +Figure 4.1-7: Life Cycle Diagram Legend + +### 4.1.3 App Development Lifecycles + +In the App Development Lifecycle only two types are defined, the **Solution App Package** and the **Solution App Type**. + +#### 4.1.3.1 Solution App Type Lifecycle + +The Development Lifecycle steps related the Solution App Type are shown below in Figure 4.1-8 错误!未找到引用源。 . + +![Figure 4.1-8: Solution App Type App Development Lifecycle. The diagram shows a vertical 'Marketplace' bar on the left. A horizontal flow starts from the Marketplace, goes through 'Ideation', 'Analysis', 'Development', and 'Train' (all in blue circles). From 'Train', a curved arrow labeled 'Build' goes down to a 'Repository' cylinder. From the 'Repository', an arrow goes up to a blue circle, which then connects back to the 'Build' arrow, forming a loop.](878c4377bd16b8009ae07442559e889a_img.jpg) + +``` + +graph LR + Marketplace[Marketplace] -- Ideation --> A(( )) + A -- Analysis --> B(( )) + B -- Development --> C(( )) + C -- Train --> D(( )) + D -- Build --> E(( )) + E --> Repository[(Repository)] + Repository --> E + +``` + +Figure 4.1-8: Solution App Type App Development Lifecycle. The diagram shows a vertical 'Marketplace' bar on the left. A horizontal flow starts from the Marketplace, goes through 'Ideation', 'Analysis', 'Development', and 'Train' (all in blue circles). From 'Train', a curved arrow labeled 'Build' goes down to a 'Repository' cylinder. From the 'Repository', an arrow goes up to a blue circle, which then connects back to the 'Build' arrow, forming a loop. + +**Figure 4.1-8: Solution App Type App Development Lifecycle** + +Customer feedback can consist of use case requirements, feature requests, defect notifications, or a variety of other comments. These feed the development cycle to develop new application or enhance existing ones. Requirements are usually identified and sent to developers to implement. The outcome of the build process is the container images built using SDKs for their intended deployments. If the application is AI/ML enabled, then the training action is done. The training might happen with synthetic data or with data provided by Service Providers. Information on the training performed will be included in the Solution Training History. The completed Solution App Type is stored in a development repository. + +#### 4.1.3.2 Solution App Package Lifecycle + +The Development Lifecycle steps related the Solution App Package are shown below in Figure 4.1-9. + +![Figure 4.1-9: Solution App Package App Development Lifecycle. The diagram shows a horizontal flow starting from a 'Repository' cylinder. An arrow labeled 'Pack' goes to a blue circle. From there, an arrow labeled 'Secure' goes to another blue circle. Finally, an arrow labeled 'Deliver' goes to a vertical 'Marketplace' bar.](d8c0094380fbcff6a72e58e0a35d043c_img.jpg) + +``` + +graph LR + Repository[(Repository)] -- Pack --> A(( )) + A -- Secure --> B(( )) + B -- Deliver --> Marketplace[Marketplace] + +``` + +Figure 4.1-9: Solution App Package App Development Lifecycle. The diagram shows a horizontal flow starting from a 'Repository' cylinder. An arrow labeled 'Pack' goes to a blue circle. From there, an arrow labeled 'Secure' goes to another blue circle. Finally, an arrow labeled 'Deliver' goes to a vertical 'Marketplace' bar. + +**Figure 4.1-9: Solution App Package App Development Lifecycle** + +The Solution App Package is used to convey the Solution App Type through the onboarding process to the Service Provider. It begins by pulling the Application App Type out of its repository and placing it in the package as mandated by the exchange requirements. Next security is applied such that the Service Provider can ensure that an Onboarded Application Package did in fact come from the expected Solution Provider. The secure package, Solution App Package, is then delivered to the Service Provider for onboarding. + +### 4.1.4 App Onboarding Lifecycles + +The App Onboarding phase deals with establishing configuration, policies, measurements, and required analytics. The App Onboarding Phase is involved with both App Packages and App Types, each with its own steps and associated actions. These will be treated separately. + +#### 4.1.4.1 Onboarded App Package Lifecycles + +The Service Design steps associated with an Onboarded App Package are shown below: + +![Figure 4.1-10: Onboarded App Package Service Provider Configuration Lifecycle. This diagram shows a linear process starting from a Marketplace. The steps are: onboard (to a green circle), verify (to another green circle), unpack (to a third green circle), and delete (to a black circle). A Catalogue database is connected to the unpack step. A feedback loop labeled 'feedback' goes from the verify step back to the Marketplace. A path labeled '[invalid]' goes from the unpack step back to the verify step.](4f3a52c49b2a187b4861ce1aa9bb2ef7_img.jpg) + +``` + +graph LR + Marketplace[Marketplace] -- onboard --> C1(( )) + C1 -- verify --> C2(( )) + C2 -- unpack --> C3(( )) + C3 -- delete --> End(( )) + C3 <--> Catalogue[(Catalogue)] + C2 -- feedback --> Marketplace + C3 -- "[invalid]" --> C2 + +``` + +Figure 4.1-10: Onboarded App Package Service Provider Configuration Lifecycle. This diagram shows a linear process starting from a Marketplace. The steps are: onboard (to a green circle), verify (to another green circle), unpack (to a third green circle), and delete (to a black circle). A Catalogue database is connected to the unpack step. A feedback loop labeled 'feedback' goes from the verify step back to the Marketplace. A path labeled '[invalid]' goes from the unpack step back to the verify step. + +**Figure 4.1-10: Onboarded App Package Service Provider Configuration Lifecycle** + +An App Package is onboarded from the exchange, and its content verified. If valid, its contents (App Types) are unpacked and the Onboarded App Package and associated Onboarded App Types catalogued. If invalid, the Service Provider can provide App Package-level feedback to the Solution Provider via the Marketplace. + +#### 4.1.4.2 Onboarded App Type Lifecycles + +The App Onboarding Phase for Onboarded App Types is split between normal processing for all applications, named "Configuration", and the lifecycle for "Training" App Types with included AI/ML Models. Workflow can interchange between these cycles iteratively. We will treat each of these separately below. + +##### 4.1.4.2.1 Onboarded App Type Configuration Lifecycle + +The Service Operator Configuration steps associated with an Onboarded App Type are shown below: + +![Figure 4.1-11: Onboarded App Type Service Provider Configuration Lifecycle. This diagram shows a complex lifecycle involving Marketplace, Catalogue, Run-Time Library, and Service Planning. Steps include: certify (from Catalogue to a green circle), publish (from green circle to another green circle), and request change (from Run-Time Library to the second green circle). A path labeled '[fail]' goes from the second green circle back to the first. A path labeled '[pass, w/suggested changes]' goes from the second green circle to the Run-Time Library. A path labeled '[initial config or training required]' goes from the first green circle to the Catalogue. A path labeled 'request change' goes from the first green circle to the Catalogue. A path labeled 'Catalogue Changes' goes from the Catalogue to the Marketplace. A path labeled 'feedback (fix requests)' goes from the Marketplace to the Catalogue. A path labeled 'feedback (feature requests)' goes from the Marketplace to the Catalogue. A path labeled '[from training]' goes from the Service Planning box to the Catalogue. A path labeled '[to training]' goes from the Catalogue to the Service Planning box. A path labeled 'request change (rAPP)' goes from the Run-Time Library to the Service Planning box. A path labeled 'request change (xAPP)' goes from the Run-Time Library to the Service Planning box.](2ea4a39bcadb72f2666d673f037c0bb7_img.jpg) + +``` + +graph LR + Marketplace[Marketplace] + Catalogue[(Catalogue)] + RunTimeLibrary[(Run-Time Library)] + ServicePlanning[Service Planning] + + Catalogue -- certify --> C1(( )) + C1 -- publish --> C2(( )) + RunTimeLibrary -- "request change" --> C2 + C2 -- "[fail]" --> C1 + C2 -- "[pass, w/suggested changes]" --> RunTimeLibrary + Catalogue -- "[initial config or training required]" --> C1 + Catalogue -- "request change" --> C1 + Catalogue -- "Catalogue Changes" --> Marketplace + Marketplace -- "feedback (fix requests)" --> Catalogue + Marketplace -- "feedback (feature requests)" --> Catalogue + ServicePlanning -- "[from training]" --> Catalogue + Catalogue -- "[to training]" --> ServicePlanning + RunTimeLibrary -- "request change (rAPP)" --> ServicePlanning + RunTimeLibrary -- "request change (xAPP)" --> ServicePlanning + +``` + +Figure 4.1-11: Onboarded App Type Service Provider Configuration Lifecycle. This diagram shows a complex lifecycle involving Marketplace, Catalogue, Run-Time Library, and Service Planning. Steps include: certify (from Catalogue to a green circle), publish (from green circle to another green circle), and request change (from Run-Time Library to the second green circle). A path labeled '[fail]' goes from the second green circle back to the first. A path labeled '[pass, w/suggested changes]' goes from the second green circle to the Run-Time Library. A path labeled '[initial config or training required]' goes from the first green circle to the Catalogue. A path labeled 'request change' goes from the first green circle to the Catalogue. A path labeled 'Catalogue Changes' goes from the Catalogue to the Marketplace. A path labeled 'feedback (fix requests)' goes from the Marketplace to the Catalogue. A path labeled 'feedback (feature requests)' goes from the Marketplace to the Catalogue. A path labeled '[from training]' goes from the Service Planning box to the Catalogue. A path labeled '[to training]' goes from the Catalogue to the Service Planning box. A path labeled 'request change (rAPP)' goes from the Run-Time Library to the Service Planning box. A path labeled 'request change (xAPP)' goes from the Run-Time Library to the Service Planning box. + +**Figure 4.1-11 Onboarded App Type Service Provider Configuration Lifecycle** + +Onboarded App Types are made visible in the SMO environment when published into the catalogue. Each recommended configuration of the App Type is certified prior to publication to a runtime library. If Certification fails, then Service Planning will determine the next course of action. + +Service Planning aggregates “fix” requests from Configuration which can be passed back to the Solution Provider (at the App Package level) as feedback across the SP interface of the Marketplace Exchange. This exchange also aggregates “change” requests from Configuration or Operations and determines if the request is for additional development (a “feature” request) or additional training (a “training” request). The former would be aggregated and + +passed back to the Solution Provider via the SP interface as described above for “fix” requests. For the latter, the Service Design: Training lifecycle would ensue. + +If the Onboarded App Type requires AI/ML training, then a request through Service Planning is used to train the model. When the "Specialized App Type" is returned, like non-ML Onboarded App Types it is catalogued and scheduled for certification. Once certified the App Type is distributed as a Published App Type to a Run Time Library. From there operations can deploy as either a management (rApp) or network application instance (xApp). + +##### 4.1.4.2.2 App Type Training Lifecycle + +The Service Operator Training Lifecycle associated with a Training App Type is shown below: + +![Diagram of the Training App Type Service Provider Training Lifecycle. A blue box labeled 'Service Planning' is at the top. Below it, a horizontal flow of four blue circles represents the training process: 'groom training data', 'train application', 'validate model', and 'promote model'. A curved arrow labeled 'schedule resources' points from 'Service Planning' to the first circle. A curved arrow labeled 'promote model' points from the last circle back to 'Service Planning'. A curved arrow labeled 'additional training required' points from the 'validate model' circle back to the 'groom training data' circle.](60afaba41ed5e87be9368a1a55391b40_img.jpg) + +``` + +graph TD + SP[Service Planning] + G1((groom training data)) + T2((train application)) + V3((validate model)) + P4((promote model)) + + SP -- "schedule resources" --> G1 + G1 --> T2 + T2 --> V3 + V3 -- "additional training required" --> G1 + V3 -- "promote model" --> SP + +``` + +Diagram of the Training App Type Service Provider Training Lifecycle. A blue box labeled 'Service Planning' is at the top. Below it, a horizontal flow of four blue circles represents the training process: 'groom training data', 'train application', 'validate model', and 'promote model'. A curved arrow labeled 'schedule resources' points from 'Service Planning' to the first circle. A curved arrow labeled 'promote model' points from the last circle back to 'Service Planning'. A curved arrow labeled 'additional training required' points from the 'validate model' circle back to the 'groom training data' circle. + +**Figure 4.1-12: Training App Type Service Provider Training Lifecycle** + +When a training request is received then resources within the training environment are scheduled for the application. Data is collected and groomed for training after which a training iteration is executed. At the end of the training cycle a test set is applied to the model and accuracy is calculated. If the test fails or other metadata indicates more training iterations are required, then the cycle repeats. Once the model is adequately trained it is promoted and sent back to service planning for continuation in another lifecycle. + +Inside the "Training Lifecycle" the process MAY require multiple iterations of training before being returned to the Service Planning MMP. + +The iteration count SHALL be included in the specialization metadata info. + +### 4.1.5 App Operation Lifecycles + +There can be many runtime environments in the service providers' network. Some can be production while others might be for non-production execution, such as offline training and lab certification. For this document we will focus on the runtime aspects of rApps, which execute within the Non-RT RIC as part of the SMO, and the xApps which execute in the near-RT RIC as part of the RAN. Although they have the same lifecycle steps the data demands due to their operational environment are different and therefore need to be independently addressed. + +#### 4.1.5.1 App Instance Lifecycles + +![Figure 4.1-13: Service Provider Runtime Lifecycles. The diagram illustrates the lifecycle of two types of applications: rApps (red) and xApps (yellow). Both follow a similar sequence of steps: Deploy, monitor, Ops&mgt, Heal & scale, and Recommend Changes. rApps are associated with a Run-Time Library and have a terminate (rApp) step. xApps are also associated with a Run-Time Library and have a terminate (xApp) step. Both terminate steps lead to a black circle, which then leads to a Service Planning block. The Service Planning block is a vertical blue rectangle on the right side of the diagram.](2f0f03faa4a7a8c407741f3a2a7e80cc_img.jpg) + +``` + +graph LR + subgraph rApp_Lifecycle [rApp Lifecycle] + rDeploy[Deploy(rApp)] --> rMonitor[monitor(rApp)] + rMonitor --> rOps[Ops&mgt (rApp)] + rOps --> rHeal[Heal & scale (rApp)] + rHeal --> rRecommend[Recommend Changes(rApp)] + rRecommend --> rTerminate((terminate (rApp))) + rTerminate --> rBlack(( )) + end + subgraph xApp_Lifecycle [xApp Lifecycle] + xDeploy[Deploy(xApp)] --> xMonitor[monitor(xApp)] + xMonitor --> xOps[Ops&mgt (xApp)] + xOps --> xHeal[Heal & scale (xApp)] + xHeal --> xRecommend[Recommend Changes(xApp)] + xRecommend --> xTerminate((terminate (xApp))) + xTerminate --> xBlack(( )) + end + rBlack --> ServicePlanning[Service Planning] + xBlack --> ServicePlanning + rDeploy -.-> rLib[Run-Time Library] + xDeploy -.-> xLib[Run-Time Library] + +``` + +Figure 4.1-13: Service Provider Runtime Lifecycles. The diagram illustrates the lifecycle of two types of applications: rApps (red) and xApps (yellow). Both follow a similar sequence of steps: Deploy, monitor, Ops&mgt, Heal & scale, and Recommend Changes. rApps are associated with a Run-Time Library and have a terminate (rApp) step. xApps are also associated with a Run-Time Library and have a terminate (xApp) step. Both terminate steps lead to a black circle, which then leads to a Service Planning block. The Service Planning block is a vertical blue rectangle on the right side of the diagram. + +Figure 4.1-13: Service Provider Runtime Lifecycles + +After the App Instance is created through a deploy operation it is monitored. As monitoring reports the health and workload of the application it is scaled up and down based on demand. Based on monitoring result, a series of operation and management functions are triggered, such as alert management, event management, incident management and further analysis. The analysis results can be guidance for further actions such as termination, healing and scaling. Finally, when its job is completed the instance is terminated. While in operation the service provider may discover defects, performance issues, or identify new features that would be beneficial. Such issue or change request will be communicated to the Service planning where the Application could be retrained or updated. The information can also be sent via the Service Planning to the Solution Provider as feedback. + +Operations determine when an application is deployed, or undeployed. Since applications are atomic, the update process is an orchestrated process of deploy and terminate. It is possible for two versions to be active at the same time, but care must be given not to provide overlapping scopes to the application instances, otherwise they may give differing directives to the network in a random order. This could cause a destabilization of the network. + +## 4.2 Common Application Lifecycle Conclusions + +The initial conclusion of Common Application Lifecycle procedures is that there is a formalized exchange between the Solution Provider and the Service Provider, the "SP Exchange". The SP Exchange consists of data describing the package and its security. The package also contains information regarding Deployment Configurations, Application Types, Deployable Components, and potentially ML Models. Further details regarding the composition of these areas will be defined through analysis of the Actions identified in section 4.1 as an action requiring further analysis (Bolded). + +# --- Appendix A: Cardinality + +This informative Appendix provides background information regarding the cardinality of different O-RAN architecture elements. It is not intended as a requirement on cardinality. + +The RAN network has an expected hierarchical fan out. Therefore, the O-RAN sizing would be: + +- Non-RT RIC (1..j) +- Near-RT RIC (1..k) +- CU-CP (1..m) +- CU-UP (1..n) +- O-DU (1..p) +- O-RU (1..q) + +Where: $1 \leq j$ ; $j \leq k$ ; $k \leq m$ ; $m \leq n$ ; $m \leq p$ ; $p \leq q$ + +Due to resiliency and scaling aspects of cloud implementations an O-DU will logically be connected to one CU-CP. The CU-CP may in fact be a pool of CU-CP instances to handle loads. + +CU-UP MEs will be pooled and aligned with the services they are configured to serve. The CU-CP will assign the CU-UP that an O-DU needs to connect to for a given UE session. + +An O-DU may serve many O-RU MEs depending on its designed capacity to manage the loop 1 processing. + +One Near-RT RIC will be connected to multiple CU-CP, CU-UP, and O-DU MEs. For resiliency the MEs may be connected to more than one Near-RT RIC, however, it shall not require duplication of data to be sent to each RIC instance. + +A Near-RT RIC will be connected to one non-RT RIC. + +# Appendix B: Sequence Diagram Template + +This section provides a common template for the description of end-to-end use cases. + +## B.1 Installing the PlantUML plugin for windows + +Follow the installation instructions found at: + +The plantuml.jar file can be downloaded from: + +The word “\*.dotm” file to use would be in the “Template\_Word\_16” ([https://github.com/plantuml/word-template/tree/master/Template\\_Word\\_2016](https://github.com/plantuml/word-template/tree/master/Template_Word_2016)) link. + +Once you have the plugin installed you can select “Show PlantUML” which will unhide the text used to generate the diagrams. + +## B.2 Plant UML Colors + +The following Palette are the named colors recognized by PlantUML. Colors can also be defined by RGB Hexcode (RRGGBB). + +``` +@startuml +colors +@enduml +``` + +| | | | | | | | | +|----------------|----------------|----------------|----------------------|-------------------|---------------|-------------|-------------| +| APPLICATION | Crimson | DeepPink | Indigo | LightYellow | Navy | RoyalBlue | Turquoise | +| AliceBlue | Cyan | DeepSkyBlue | Ivory | Lime | OldLace | STRATEGY | Violet | +| AntiqueWhite | DarkBlue | DimGray | Khaki | LimeGreen | Olive | SaddleBrown | Wheat | +| Aqua | DarkCyan | DimGrey | Lavender | Linen | OliveDrab | Salmon | White | +| Aquamarine | DarkGoldenRod | DodgerBlue | LavenderBlush | MOTIVATION | Orange | SandyBrown | WhiteSmoke | +| Azure | DarkGray | FireBrick | LawnGreen | Magenta | OrangeRed | SeaGreen | Yellow | +| BUSINESS | DarkGreen | FloralWhite | LemonChiffon | Maroon | Orchid | SeaShell | YellowGreen | +| Beige | DarkGrey | ForestGreen | LightBlue | MediumAquaMarine | PHYSICAL | Sienna | | +| Bisque | DarkKhaki | Fuchsia | LightCoral | MediumBlue | PaleGoldenRod | Silver | | +| Black | DarkMagenta | Gainsboro | LightCyan | MediumOrchid | PaleGreen | SkyBlue | | +| BlanchedAlmond | DarkOliveGreen | GhostWhite | LightGoldenRodYellow | MediumPurple | PaleTurquoise | SlateBlue | | +| Blue | DarkOrchid | Gold | LightGray | MediumSeaGreen | PaleVioletRed | SlateGray | | +| BlueViolet | DarkRed | GoldenRod | LightGreen | MediumSlateBlue | PapayaWhip | SlateGrey | | +| Brown | DarkSalmon | Gray | LightGrey | MediumSpringGreen | PeachPuff | Snow | | +| BurlyWood | DarkSeaGreen | Green | LightPink | MediumTurquoise | Peru | SpringGreen | | +| CadetBlue | DarkSlateBlue | GreenYellow | LightSalmon | MediumVioletRed | Pink | SteelBlue | | +| Chartreuse | DarkSlateGray | Grey | LightSeaGreen | MidnightBlue | Plum | TECHNOLOGY | | +| Chocolate | DarkSlateGrey | HoneyDew | LightSkyBlue | MintCream | PowderBlue | Tan | | +| Coral | DarkTurquoise | HotPink | LightSlateGray | MistyRose | Purple | Teal | | +| CornflowerBlue | DarkViolet | IMPLEMENTATION | LightSlateGrey | Moccasin | Red | Thistle | | +| Cornsilk | Darkorange | IndianRed | LightSteelBlue | NavajoWhite | RosyBrown | Tomato | | + +## B.3 Depicting human actors as participants + +The participant type Actor should be used. For Clarity these should be the first group and therefore always on the left side of the diagram. The color “#lightblue” has been identified as the background for this group of use case participants. + +``` +@startuml +Box "Personnel" #lightblue + Actor FT as "Field Technician" + Actor RP as "Radio Planner" +End box +@enduml +``` + +![UML diagram titled 'Personnel' showing four stick figures arranged in a 2x2 grid. The top row is labeled 'Field Technician' and 'Radio Planner', and the bottom row is also labeled 'Field Technician' and 'Radio Planner'.](4f2fd1bd24583f321e09b5189b21facf_img.jpg) + +UML diagram titled 'Personnel' showing four stick figures arranged in a 2x2 grid. The top row is labeled 'Field Technician' and 'Radio Planner', and the bottom row is also labeled 'Field Technician' and 'Radio Planner'. + +At times it may be desirable to identify external data sources. These would be presented using the same color as personnel but be titled as Non-RAN Data. The Source of the data would be identified as an “Entity”. The list of these could be immense but small within the context of a use case. Therefore, a few examples are shown below, and is not intended to be an exhaustive list. + +``` +@startuml +Box "Non-RAN Data" #lightblue + Entity weather as "Weather Data" + Entity fire as "Fire Data" + Entity earth as "Earthquake Data" + Entity subs as "Subscriber Data" +End box +@enduml +``` + +![UML diagram titled 'Non-RAN Data' showing four circles arranged in a 2x2 grid. The top row is labeled 'Weather Data', 'Fire Data', 'Earthquake Data', and 'Subscriber Data'. The bottom row is also labeled 'Weather Data', 'Fire Data', 'Earthquake Data', and 'Subscriber Data'.](5c5a1d09f19f5e6ad84c385c791bb007_img.jpg) + +UML diagram titled 'Non-RAN Data' showing four circles arranged in a 2x2 grid. The top row is labeled 'Weather Data', 'Fire Data', 'Earthquake Data', and 'Subscriber Data'. The bottom row is also labeled 'Weather Data', 'Fire Data', 'Earthquake Data', and 'Subscriber Data'. + +## B.4 Depicting Service Management and Orchestration Participants + +Service Management and Orchestration participants can vary by type. The following UML shows the standard types for defined participants. Participants can be deleted when not pertinent to the use case but additional participants should be avoided unless they are defined in the O-RAN Architecture Description [17] or other O-RAN specifications. For consistency SMO should be the second group unless the personnel group is not required which would make this the first group. The color “#gold” has been identified as the background for this group of use case participants. + +The O-RAN Architecture [17] identifies three types of functions in SMO: FCAPS for O-RAN Network Functions(named here as “OAM Functions”), Non-RT RIC, and O-Cloud Management, Orchestration and Workflow Management. The O2 General Aspects and Principles [21] further distinguishes between management of the distribution of O-Cloud software and orchestration for O-Cloud life cycle processes, called “Federated O-Cloud Operations and Management”, or “FOCOM”, and coordination between SMO and the O-Cloud for managing deployment life cycle events and operational processes, called “Network Function Orchestration”, or “NFO”. These are shown as participants in the UML as below. + +``` +@startuml +Box "Service Orchestration and Management Framework" #gold + participant NFO + participant SMO as "OAM Functions" + Collections RPGF as "non-RT RIC" + Participant FOCOM +End box +@enduml +``` + +``` +end box +``` + +``` +@enduml +``` + +![Service Orchestration and Management Framework diagram](db0be88c08f50a86f90cf5db3788e79d_img.jpg) + +The diagram shows a yellow rectangular box titled "Service Orchestration and Management Framework". Inside the box, there are two rows of four components each. The top row contains "NFO", "OAM Functions", "non-RT RIC", and "FOCOM". The bottom row contains "NFO", "OAM Functions", "non-RT RIC", and "FOCOM". Vertical dashed lines connect each component in the top row to its corresponding component in the bottom row. + +Service Orchestration and Management Framework diagram + +## B.5 Depicting Cloud Platform Participants + +As described in the O-Ran Architecture Description [17] the Cloud platform has two roles. These are depicted by the end points in the O-Cloud Management and Control Planes. The Infrastructure Management Services (IMS) provides management of the O-Cloud as a platform. The Deployment Management Services (DMS) provides management of Deployments using the O-Cloud resources. Like in the SMO the internal software modules and components to the O-Cloud can vary from implementation to implementation. Therefore it is not advised to add additional entities unless it is unavoidable for the use case. The color "#lightseagreen" has been identified as the background for this group of use case participants. + +``` +@startuml +Box "O-Cloud Platform" #lightseagreen + participant IMS + participant DMS +End box +@enduml +``` + +![O-Cloud Platform diagram](a1755af0837868e049d85932c9b4b766_img.jpg) + +The diagram shows a teal rectangular box titled "O-Cloud Platform". Inside the box, there are two rows of two components each. The top row contains "IMS" and "DMS". The bottom row contains "IMS" and "DMS". Vertical dashed lines connect each component in the top row to its corresponding component in the bottom row. + +O-Cloud Platform diagram + +## B.6 O-RAN Managed Elements as participants + +The O-RAN architecture defines 5 Managed Functions (MF) which can be deployed independently or aggregated in different ways into a Managed Element (ME). The O-CU is a predefined aggregation of the O-CU-CP and O-CU-UP. + +``` +@startuml +Box "O-RAN" #lightpink + Participant RIC as "near-RT RIC" + Participant OCUCP as "O-CU-CP" + Participant OCUUP as "O-CU-UP" + Participant OCU as "O-CU" + Participant ODU as "O-DU" + Participant ORU as "O-RU" +end box +@enduml +``` + +![O-RAN diagram](6934367c554f2aa08d13477a6e9bc324_img.jpg) + +The diagram shows a pink rectangular box titled "O-RAN". Inside the box, there are two rows of six components each. The top row contains "near-RT RIC", "O-CU-CP", "O-CU-UP", "O-CU", "O-DU", and "O-RU". The bottom row contains "near-RT RIC", "O-CU-CP", "O-CU-UP", "O-CU", "O-DU", and "O-RU". Vertical dashed lines connect each component in the top row to its corresponding component in the bottom row. + +O-RAN diagram + +## B.7 3GPP RAN elements as participants + +On occasion some use cases may need to show interaction between O-RAN and 3GPP elements. 3GPP defines both LTE and 5G elements. The gNodeB is also defined with a split defining the Centralized Unit (CU) and the Distributed Unit (DU). These participants are in the 3GPP RAN box with a background of “#Tan”. + +``` +@startuml +Box "3GPP RAN" #Tan + Participant eNB + Participant gNB + Participant CU + Participant DU +Endbox +@enduml +``` + +![Diagram of 3GPP RAN box containing eNB, gNB, CU, and DU participants.](33a4db925b455250193a2b85a0a64434_img.jpg) + +The diagram shows a box labeled "3GPP RAN" with a tan background. Inside the box, there are four yellow boxes representing participants: eNB, gNB, CU, and DU. Each of these four boxes is connected by a dashed line to a corresponding box below it, also labeled eNB, gNB, CU, and DU respectively. + +Diagram of 3GPP RAN box containing eNB, gNB, CU, and DU participants. + +## B.8 Messaging + +Autonumber should be used so that individual messages in a diagram can be easily referenced in conversation. Synchronous calls have an implicit return or the return can be implicitly depicted, often after a long block so as to provide clarity of where processing continues. Some use cases can be used with a start message and end with either a message or response. This is helpful when a common block can be used multiple times. + +``` +@startuml +Autonumber +Participant One +Participant Two +[-> One : Use Case incoming message +One -> Two: Synchronous Call +Two ->> One : Asynchronous message +One -> One : Call to Self +Two ->] : Use Case outgoing message +Two --> One : Explicit Synchronous Return +[<-- One : Use Case Return Message +@enduml +``` + +![Sequence diagram showing messages between One and Two participants.](88aca3358e5b5e5ed706373dd744e5e0_img.jpg) + +The sequence diagram shows two participants, One and Two, represented by yellow boxes. The messages are as follows: + +- 1 Use Case incoming message:** A solid red arrow pointing to participant One from the left. +- 2 Synchronous Call:** A solid red arrow pointing from participant One to participant Two. +- 3 Asynchronous message:** A solid red arrow pointing from participant Two back to participant One. +- 4 Call to Self:** A solid red arrow pointing from participant One back to participant One. +- 5 Use Case outgoing message:** A solid red arrow pointing from participant Two to the right. +- 6 Explicit Synchronous Return:** A solid red arrow pointing from participant Two back to participant One. +- 7 Use Case Return Message:** A dashed red arrow pointing from participant One to the left. + +Sequence diagram showing messages between One and Two participants. + +### 1 B.9 Adding Comments + +2 Comments can be added to the diagram. This is sometimes better than trying to describe the comment in text or for the +3 picture to be able to standalone. + +``` + +4 @startuml +5 Autonumber +6 Participant One +7 Participant Two +8 Note over One +9 Notes can be used and placed over a lifeline +10 To describe something happening along that line +11 End note +12 [-> One : Use Case incoming message +13 Rnote over One, Two +14 Notes can be a simple rectangle instead of the standard +15 Note above and can be spanning multiple life lines to +16 Describe the interaction about to occur +17 endrnote +18 One -> Two: Synchronous Call +19 Hnote right One +20 The can be hexagonal and to the Right +21 Endhnote +22 Hnote over One +23 Over +24 endhnote +25 Hnote left One +26 Or Left of a lifeline +27 endhnote +28 Two -> Two : +29 Note Right : Messages on notes can\nbe used to describe\ninternal processing\nwithout +30 adding to\nparticipant spacing. +31 Two ->> One : Asynchronous message +32 Note Left: Message Notes can be\nright or left of the\nmessage but must be\nimmediately +33 after the\nmessage they are noting. +34 Note over One #fuchsia +35 Note backgrounds can be **changed** as //well// as the __text__ +36 End note +37 One -> One : Call to Self +38 Two ->] : Use Case outgoing message +39 Two --> One : Explicit Synchronous Return +40 [ <-- One : Use Case Return Message +41 @enduml + +``` + +![UML sequence diagram illustrating various message types and note usage between two participants, One and Two.](84b3c55c644e95de07e42dc9cfb55621_img.jpg) + +The diagram shows two lifelines, 'One' and 'Two', with various messages and notes. Notes are highlighted in yellow boxes, and a background note is in a pink box. + +- 1 Use Case incoming message:** A solid arrow from the left to participant 'One'. +- Note:** Notes can be used and placed over a lifeline To describe something happening along that line. +- Note:** Notes can be a simple rectangle instead of the standard Note above and can be spanning multiple life lines to Describe the interaction about to occur. +- 2 Synchronous Call:** A solid arrow from participant 'One' to participant 'Two'. +- Note:** The can be hexagonal and to the Right. +- Note:** Over. +- Note:** Or Left of a lifeline. +- 3:** A small rectangle on participant 'Two'. +- Note:** Messages on notes can be used to describe internal processing without adding to participant spacing. +- 4 Asynchronous message:** A solid arrow from participant 'Two' to participant 'One'. +- Note:** Message Notes can be right or left of the message but must be immediately after the message they are noting. +- Note:** Note backgrounds can be **changed** as well as the text. +- 5 Call to Self:** A solid arrow from participant 'One' to itself. +- 6 Use Case outgoing message:** A solid arrow from participant 'Two' to the right. +- 7 Explicit Synchronous Return:** A dashed arrow from participant 'Two' back to participant 'One'. +- 8 Use Case Return Message:** A dashed arrow from participant 'One' to the left. + +UML sequence diagram illustrating various message types and note usage between two participants, One and Two. + +1 + +### 2 B.10 Participant Creation/Deletion + +3 Sometimes clarity is depicted by showing when a participant is created or first comes into being and likewise when it is +4 destroyed. This is very helpful in understanding timing and existence of a participant. This happens with modifiers to +5 the message. + +``` +6 @startuml +7 Autounumber +8 Participant One +9 Participant Two +10 [-> One : Use Case incoming message +``` + +``` + +One -> Two **: Synchronous Call +Two ->> One : Asynchronous message +Two ->] : Use Case outgoing message +Two -> Two !! : Terminate +One -> One : Call to Self +[<-- One : Use Case Return Message +@enduml + +``` + +![UML sequence diagram showing interactions between One and Two. 1. Incoming message to One. 2. Synchronous call from One to Two. 3. Asynchronous message from Two to One. 4. Outgoing message from Two. 5. Terminate on Two. 6. Call to self on One. 7. Return message from One.](f94522878c4d2f1caa321216dd75d223_img.jpg) + +``` + +sequenceDiagram + participant One + participant Two + Note left of One: 1 Use Case incoming message + One->>Two: 2 Synchronous Call + Two-->>One: 3 Asynchronous message + Two->>: 4 Use Case outgoing message + Two--x: 5 Terminate + One->>One: 6 Call to Self + One-->>: 7 Use Case Return Message + +``` + +UML sequence diagram showing interactions between One and Two. 1. Incoming message to One. 2. Synchronous call from One to Two. 3. Asynchronous message from Two to One. 4. Outgoing message from Two. 5. Terminate on Two. 6. Call to self on One. 7. Return message from One. + +## B.11 Dividers + +In some cases, it is helpful to provide divisions of separate activities of the use case. This can be to define pre-requisite activity such as configuration or subscriptions to an event. It can also be used to depict stages of a lifecycle. + +``` + +@startuml +Autonumber +Box "Personnel" #lightblue + Actor FT as "Field Technician" + Actor RP as "Radio Planner" + Actor SD as "Service Designer" +End box + +Box "Orchestration and Management Platform" #gold + participant SMO as "OAM Functions" +end box + +Box "O-Cloud Platform" #lightseagreen + participant OCM as "IMS" +End box + +Box "O-RAN" #NavajoWhite + Participant OCU as "O-CU" +end box + +Box "3GPP RAN" #Tan + Participant DU +Endbox + +== Service Design == +SD -> SMO : Onboard Service Descriptor +SMO -> OCM : Onboard VNF Descriptor + +``` + +``` +== Service Deploy == +RP -> SMO : Deploy Service + +== VNF Instantiate == +SMO -> OCM : Instantiate +OCM -> OCU **: Create VNF +OCM --> SMO : VNF Created +SMO -> OCU : Configure +== PNF Discovery == +FT -> DU **: Poweron +DU -> SMO : PNF Register +SMO -> SMO : PNF On Network +SMO -> DU : Configure +== Operate == +DU <-> OCU : Traffic +@enduml +``` + +![Sequence diagram illustrating the OAM Architecture process across five swimlanes: Personnel, Orchestration and Management Platform, O-Cloud Platform, O-RAN, and 3GPP RAN.](57f4eeef16b695bc408f5435d1a85102_img.jpg) + +The diagram illustrates the OAM Architecture process across five swimlanes: Personnel, Orchestration and Management Platform, O-Cloud Platform, O-RAN, and 3GPP RAN. + +- Personnel:** Field Technician, Radio Planner, Service Designer. +- Orchestration and Management Platform:** OAM Functions, Service Design, Service Deploy, VNF Instantiate, PNF Discovery, Operate. +- O-Cloud Platform:** IMS. +- O-RAN:** O-CU. +- 3GPP RAN:** DU. + +The process flow is as follows: + +- Service Design:** Personnel (Service Designer) sends "1 Onboard Service Descriptor" to OAM Functions. OAM Functions sends "2 Onboard VNF Descriptor" to O-Cloud Platform (IMS). +- Service Deploy:** Personnel (Radio Planner) sends "3 Deploy Service" to OAM Functions. +- VNF Instantiate:** OAM Functions sends "4 Instantiate" to O-Cloud Platform (IMS). O-Cloud Platform (IMS) sends "5 Create VNF" to O-RAN (O-CU). O-RAN (O-CU) sends "6 VNF Created" to OAM Functions. OAM Functions sends "7 Configure" to O-RAN (O-CU). +- PNF Discovery:** Personnel (Field Technician) sends "8 Poweron" to 3GPP RAN (DU). 3GPP RAN (DU) sends "9 PNF Register" to OAM Functions. OAM Functions sends "10 PNF On Network" to OAM Functions. OAM Functions sends "11 Configure" to 3GPP RAN (DU). +- Operate:** 3GPP RAN (DU) sends "12 Traffic" to O-RAN (O-CU). + +Sequence diagram illustrating the OAM Architecture process across five swimlanes: Personnel, Orchestration and Management Platform, O-Cloud Platform, O-RAN, and 3GPP RAN. + +## B.12 Grouping and References + +Grouping can be used for many different aspects. In UML there are many types of groups. PlantUML support the basic three. Any of the group types can be nested. "Alt" for conditional processing which can show different path processing rather than just a sunny day scenario. It can also be used to show any logical, as the condition is stated in the swim lane, processing. Sometimes the message and the grouping boundary are close and need some separation. Use the "|||" to create that space. + +The "loop" group is used to show iterations or conditional loops. The loop condition is stated on the lines and contain the statements within the loop. + +The last kind of group is the fragment. This is a logic group of a sequence of events that go together. The tag line at the top describes the group. + +Although references look like groups they cannot be nested. Use the single line version for references to use cases in the current document. The Multi-Line version should be used for reference to use cases in an external document. + +``` + +@startuml +Box "Orchestration and Management Platform" #gold + participant SMO as "Orchestration" +end box + +Box "O-RAN" #NavajoWhite + Participant ODU as "O-DU" + Participant ORU as "O-RU" +end box + +Group Configure O-RU associated with O-DU +Alt if flat management model then + Loop for each O-RU managed by the current O-DU + SMO -> ORU : Config (Full_Config) + ref over ORU : Edit-Config (Internal Document Reference) + Hnote over ORU + Ready + Endhnote + End + ||| +Else else if hierarchical model then + SMO -> ODU : Config_RU (Global_Config) + Loop for each O-RU managed by this O-DU instance + ODU -> ODU : Full_Config = Config_Merge (Global_Config, Local_Config) + ODU -> ORU : Config (Full_Config) + ref over ORU + Edit-Config (External Document Reference) + WG4 M-Plane Specification [12] + End ref + Hnote over ORU + Ready + endhnote + end + ||| +Else else must be hybrid model then + Rnote over SMO, ORU + Order of Global and Local Configuration can vary + Endrnote + Loop for each O-RU managed by the current O-DU + SMO -> ORU : Config (Global_Config) + end + Loop for each O-RU managed by this O-DU instance + ODU -> ORU : Config (Local_Config) + end + Alt If both Local_Config and Local_Config Received then + ref over ORU + Edit-Config + WG4 M-Plane Specification [12] + End ref + Hnote over ORU + Ready + endhnote + ||| + End +End +end +@enduml + +``` + +![Sequence diagram titled 'Configure O-RU associated with O-DU' showing interactions between Orchestration, O-DU, and O-RU. The diagram is divided into three main sections: 'if flat management model then', 'if hierarchical model then', and 'if must be hybrid model then'. It includes loops for configuring O-RUs, references to external documents, and a 'Ready' state.](2b7095d8ec9e7509aefaa08903ce194f_img.jpg) + +``` + +sequenceDiagram + participant Orchestration + participant O-DU + participant O-RU + + alt [if flat management model then] + loop [for each O-RU managed by the current O-DU] + Orchestration->>O-RU: Config (Full_Config) + O-RU->>O-DU: Edit-Config (Internal Document Reference) + O-RU->>O-DU: Ready + end + else [if hierarchical model then] + Orchestration->>O-DU: Config_RU (Global_Config) + loop [for each O-RU managed by this O-DU instance] + O-DU->>O-DU: Full_Config = Config_Merge (Global_Config, Local_Config) + O-DU->>O-RU: Config (Full_Config) + O-RU->>O-DU: Edit-Config (External Document Reference) WG4 M-Plane Specification [6] + O-RU->>O-DU: Ready + end + else [if must be hybrid model then] + Note over Orchestration, O-DU: Order of Global and Local Configuration can vary + loop [for each O-RU managed by the current O-DU] + Orchestration->>O-RU: Config (Global_Config) + end + loop [for each O-RU managed by this O-DU instance] + O-DU->>O-RU: Config (Local_Config) + end + alt [if both Local_Config and Local_Config Received then] + O-RU->>O-DU: Edit-Config WG4 M-Plane Specification [6] + O-RU->>O-DU: Ready + end + end + +``` + +Sequence diagram titled 'Configure O-RU associated with O-DU' showing interactions between Orchestration, O-DU, and O-RU. The diagram is divided into three main sections: 'if flat management model then', 'if hierarchical model then', and 'if must be hybrid model then'. It includes loops for configuring O-RUs, references to external documents, and a 'Ready' state. + +1 +2 + +# Annex A: SMO and Non-RT RIC mapping with 3GPP management system + +This section shows the SMO, Non-RT RIC and the related management interface/service mapping with 3GPP management system. + +In [9], 3GPP defines the network management and orchestration architecture for 3GPP networks including network slicing. The management data analytic function (MDAF) is identified as the key function to enable the intelligent management of the network, which provides management data analytics service (MDAS) to both the management functions and the network element. Meanwhile, intent driven management service (IDMS) is under discussion in 3GPP SA5, where the management system could generate intent as the target of the network optimization and automation. The management system should have the capability to consume the service (IDMS) provided by the network. Currently, the two studies are mainly to enable the network management automaton and intelligence. In this sense, it is quite aligned with the motivation of introducing Non-RT RIC in O-RAN. + +To better understand the O-RAN OAM architecture, the management services defined in O-RAN, and the relationship with 3GPP and the potential gaps between 3GPP and O-RAN. Fig. A-1 below tries to do some mapping between the SMO, Non-RT RIC and 3GPP management system and interfaces with the following preliminary analysis. + +1. A1 interface is closely related to the current SA5 3GPP IDMS and MDAS study. + +(1) A1-P, as declarative policy is closely related to Intent-NOP discussed in IDMS. Performance target is expected to be provided by management system via the IDMS. But only system level targets are being discussed in the IDMS study. A1-P is finer granularity to enable the UE level, group UE level and even application level automation and optimization. + +(2) A1-EI/ML is closely related to the 3GPP MDAS study. MDAS provider is expected to provide data analytics reports and recommendations to the consumers, e.g., CN or RAN leveraging the data analytics and machine learning technologies. AI-EI/ML studied in O-RAN is to enable the enrichment information communication and ML model management towards the RAN. The enrichment information may come from the data analytics based on the historical RAN data collected over O1 interface or from RAN external data sources. In this sense, A1-EI/ML has a larger scope than the MDAS in 3GPP. + +2. O1 interface reflects the 3GPP traditional FCAPS management services. + +3. O2 interface perform the O-Cloud management, the mapping with 3GPP is FFS. + +4. Non-RT RIC could be seen as a MDAF instance, which provides management data analytic service to both internal functions reside in the SMO and external consumers such as near-RT RIC. + +The management service, Non-RT RIC and A1 work in O-RAN will continue evolve and the MDAS/IDMS related SI/WI are under study and still in early stage in 3GPP. The gap analysis and mapping relationship will be continuously updated based on the latest progress. + +![Figure A-1: SMO and Non-RT RIC mapping with the 3GPP management system. The diagram shows the SMO Framework and Non-RT RIC components, their internal functions, and their mapping to 3GPP management systems.](b4b42adb2f1ac70e17db52a41ce055c4_img.jpg) + +The diagram illustrates the mapping between O-RAN components and 3GPP management systems. It is divided into two main sections: SMO Framework and Non-RT RIC. + +**SMO Framework:** + +- OAM Functions:** A group of functions including SM, AM, SW mgnt, and O-Cloud mgnt. Some are in dashed boxes (3GPP already defined), while others are in solid boxes (O-RAN defined). +- Integration fabric and data service:** A central component connecting the OAM functions. + +**Non-RT RIC:** + +- A1 Policy management, A1 EI management, A1 ML management:** These are in dashed boxes, indicating they are 3GPP already defined. +- Data Analytics and AI/ML model training:** This is in a dashed box, indicating it is 3GPP already defined. +- A1-P and A1-EI/A1-ML:** These are labels for the interfaces/services provided by the Non-RT RIC. + +**Mapping to 3GPP Management Systems:** + +- 3GPP traditional FCAPS:** Mapped from the SMO Framework's OAM Functions. +- 3GPP IDM (intent NOP) (NOP: Network Operator):** Mapped from the Non-RT RIC's A1 Policy management. +- 3GPP MDAF/MDAS:** Mapped from the Non-RT RIC's A1-EI/A1-ML. + +**Legend:** + +- 3GPP already defined, so far not used in O-RAN OAM Functions +- 3GPP and O-RAN are studying +- O-RAN defined, so far not used in 3GPP + +Figure A-1: SMO and Non-RT RIC mapping with the 3GPP management system. The diagram shows the SMO Framework and Non-RT RIC components, their internal functions, and their mapping to 3GPP management systems. + +Figure A- 1: SMO and Non-RT RIC mapping with the 3GPP management system + +1    *Note :* + +- 2    *i.     The figure shows the entire services provided by the SMO Framework, the O-Cloud management and Integration* +3        *fabric and data service defined by O-RAN so far there is no corresponding services defined in 3GPP.* +- 4    *ii.    The Security management service and Accounting management defined in 3GPP so far they are not used in OAM* +5        *Functions.* +- 6    *iii.   The AI Policy management, AI EI management, AI ML management are being studied in O-RAN and being* +7        *implemented in O-RAN software community.* +- 8    *iv.    The AI Policy management maps to 3GPP IDMS.* +- 9    *v.     AI EI management and AI ML management is correlated to the MDAS, when the EI is retrieved from the Data* +10       *Analytic and AI/ML Model Training, the concrete mapping relationship with 3GPP is FFS.* +- 11   *vi.    The Data Analytics and AI/ML Model Training studied in O-RAN maps to 3GPP RAN domain MDAS producer.* + +12 + +# Annex ZZZ : O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN + +Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated + +that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of O-RAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance's sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. + +Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or third party beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full force and effect. + +# --- Chapter 5. \ No newline at end of file diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/012c78dfb8458b18fc0dd72fc7078e28_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/012c78dfb8458b18fc0dd72fc7078e28_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3094a633cc539b06cd2cfa119b8d91ffd48a58ee --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/012c78dfb8458b18fc0dd72fc7078e28_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:05374a2567802cc10c19fbc80809573460114893f67384cfec8528d4ee410dac +size 31593 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/1b43542eb262785f22df8e72fe462a53_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/1b43542eb262785f22df8e72fe462a53_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a4efc1a456bd94560ef0bf282b81ace9ce7db4a5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/1b43542eb262785f22df8e72fe462a53_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:65d04386ecd7e939a20b7de55d60b0f4d5f90c1cc30682d3c508a5a1ec4f504e +size 35938 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/23e6da2f6f6826696020dce4f14fdfe5_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/23e6da2f6f6826696020dce4f14fdfe5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b992fd9db76227f22675fa88dc9d850e5a2f1e47 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/23e6da2f6f6826696020dce4f14fdfe5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b003ffeb656623bd278f6e0cf1b2bb9a83a7c5eedbafb0f5dc3dde491ed578d8 +size 32088 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/3bb1468d23787cbe05312e5d6b0106b8_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/3bb1468d23787cbe05312e5d6b0106b8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..830bf83a274d0b899a224fc10370ee09c90550d9 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/3bb1468d23787cbe05312e5d6b0106b8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:65b2cf70b8761f1a81ea85954e61c2a814e8ee536fcdfc262588325743d8f88f +size 38889 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/4528fe480fbe9fc9b4a28c6416c43206_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/4528fe480fbe9fc9b4a28c6416c43206_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c15a9b443b94c783b4b1641aa2899d514b0991af --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/4528fe480fbe9fc9b4a28c6416c43206_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ff285a50970985df42dc8b05e0c45fbddf2ae627c55114c4dd4810798a1c7daf +size 53650 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/5755ffd47b0782111fe6a2d99e72764e_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/5755ffd47b0782111fe6a2d99e72764e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e9fdd0418f6d243eb7a6fc39c3a5a210ebade899 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/5755ffd47b0782111fe6a2d99e72764e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1002c86aef2acbc14fda7f5215179c57dec7aa14f9dd86d7459b14a54006a6fc +size 90000 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/6292e6c9be00321cb184d2b101992549_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/6292e6c9be00321cb184d2b101992549_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..39011cdab27ee913e1ca087f29fdcc3802c89b71 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/6292e6c9be00321cb184d2b101992549_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b0e44e6839fc4c2018f7bd21b79c28568b1d080b15af370c79abb7dd09281e2f +size 4535 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/7ba19f20df08acb640a7aea77c3ddca1_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/7ba19f20df08acb640a7aea77c3ddca1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..565148ec6009337f56f788f8a6d94651e84ee2d9 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/7ba19f20df08acb640a7aea77c3ddca1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:01dedc68fcbcae174790e753c03ec4ef6700bdcda7eb304dfed3803986da5ca9 +size 63868 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/a8c57fb53cd9939c015ec95b95c49848_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/a8c57fb53cd9939c015ec95b95c49848_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f100010e5ea3cba66f1993396f48b3f674f1efb2 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/a8c57fb53cd9939c015ec95b95c49848_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7a3a2503a943a60bf10738d510ad8ef55f747cb0127911b92d985910122bd2ed +size 34532 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/b04f8982ef1411efba3ad1656bbef224_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/b04f8982ef1411efba3ad1656bbef224_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7c1a4f5cc2e8f1dd9b22da704455fdbe9e57c969 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/b04f8982ef1411efba3ad1656bbef224_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:23d49e7ad3346aba00d62cacbe616e6be2f615a1603ca23108e3e9b4f9713407 +size 54105 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/ba15e62707a1e66c4dfbaea7645f5e05_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/ba15e62707a1e66c4dfbaea7645f5e05_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0c74f4e96321bd82ffa867eb9098db0eaf6be49f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/ba15e62707a1e66c4dfbaea7645f5e05_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:540a6e319dbe528ba2085aab64e71702f865402fa33520a679bbc8f43ea61192 +size 59288 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7575c364a05dd515d7cf096c30ffc26f8ab2631 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b321cfff0a169d11fa6daa2e14ee4667e12bcfeff34e35ee9dd80b810a6385a6 +size 4491 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/e0928093b776691a1c6c70735492ac2a_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/e0928093b776691a1c6c70735492ac2a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1570f718e8eb28246a1e38994d6f02de75d0e225 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/e0928093b776691a1c6c70735492ac2a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a7bf1ae09bd8098fb72bb2206f212ced306d0bdfcee343692e8ecb4069864747 +size 48161 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/e2473eccff9a2db043bbfa17e69afd0a_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/e2473eccff9a2db043bbfa17e69afd0a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4412f5ee8d1077ea6c51b512de4bc028ef71ccdb --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/e2473eccff9a2db043bbfa17e69afd0a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c8824637e3705bab6691ff56e4ad52fbd4863b8f9738ca46d1a7ff03b7478788 +size 45282 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/raw.md b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..8a924b3325b192c23348c596659e8ece20aca625 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00/raw.md @@ -0,0 +1,701 @@ + + +# **O-RAN Working Group 1 Study on O-RAN Slicing** --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Working Group 1 Study on O-RAN Slicing** --- + +Prepared by the O-RAN Alliance e.V. Copyright © 2020 by the O-RAN Alliance e.V. By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in the Annex ZZZ of this specification. All other rights reserved. + +1 + +# Revision History + +| Date | Revision | Author | Description | +|------------|----------|------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2019.12.16 | 02.00.01 | Arda Akman (Netsia) | Initial version of v2.0 (and deletion of v1.0 revision history) | +| 2019.12.26 | 02.00.02 | Arda Akman (Netsia),
Tuğba Arıcı (Netsia) | Update to SDO Mapping table to add
  • - Fault Management
  • - Security Aspects
| +| 2019.12.29 | 02.00.03 | Arda Akman (Netsia),
Tuğba Arıcı (Netsia) | Updates to GSMA section to reflect the latest GSMA specs | +| 2020.01.20 | 02.00.04 | Arda Akman (Netsia),
Burcu Yargıçoğlu
Şahin (Netsia) | Addition of O1, A1, E2, O2 impact and Deployment Options sections through CR:
  • - ORAN-WG1.Netsia_CR_StudyO-RAN-Slicing_20012020
| +| 2020.03.01 | 02.00.05 | Arda Akman (Netsia) | Updated references, abbreviations, deployment options and other editorial updates | +| 2020.03.09 | 02.00.06 | Arda Akman (Netsia) | Updates to various sections based on review feedback during WG1 approval process | + +2 + +3 + +4 + +# Contents + +| | | | | +|----|--------------------------------------------------------------|----|--| +| 1 | | | | +| 2 | Revision History..... | 2 | | +| 3 | Chapter 1 Introduction..... | 4 | | +| 4 | 1.1 Scope ..... | 4 | | +| 5 | 1.2 References..... | 4 | | +| 6 | 1.3 Definitions and Abbreviations ..... | 5 | | +| 7 | 1.3.1 Definitions..... | 5 | | +| 8 | 1.3.2 Abbreviations ..... | 6 | | +| 9 | Chapter 2 Objective..... | 7 | | +| 10 | Chapter 3 Common Terminology..... | 8 | | +| 11 | Chapter 4 Slicing in SDOs ..... | 9 | | +| 12 | 4.1 Slicing in 3GPP..... | 9 | | +| 13 | 4.2 Slicing in ONAP ..... | 11 | | +| 14 | 4.3 Slicing Orchestration in 3GPP SA5 and ETSI NFV MANO..... | 12 | | +| 15 | 4.4 Slicing in ETSI ZSM ..... | 14 | | +| 16 | 4.5 Slicing in GSMA ..... | 16 | | +| 17 | Chapter 5 O-RAN Slicing Framework..... | 18 | | +| 18 | 5.1 O-RAN Slicing Architecture..... | 18 | | +| 19 | 5.1.1 Non-RT RIC..... | 18 | | +| 20 | 5.1.2 Near-RT RIC..... | 18 | | +| 21 | 5.1.3 O-RAN Central Unit (O-CU)..... | 18 | | +| 22 | 5.1.4 O-RAN Distributed Unit (O-DU)..... | 18 | | +| 23 | 5.1.5 A1 Impact..... | 19 | | +| 24 | 5.1.6 E2 Impact ..... | 19 | | +| 25 | 5.1.7 O1 Impact..... | 19 | | +| 26 | 5.1.8 O2 Impact..... | 19 | | +| 27 | Chapter 6 Deployment Options ..... | 20 | | +| 28 | Annex A (informative): Additional Information ..... | 23 | | +| 29 | A.1 Slicing SDO Mapping Table..... | 23 | | +| 30 | Annex ZZZ O-RAN Adopter License Agreement ..... | 24 | | +| 31 | | | | +| 32 | | | | +| 33 | | | | +| 34 | | | | + +# Chapter 1 Introduction + +## 1.1 Scope + +This Technical Report has been produced by O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN WG1 Slicing Task Group and may change following formal O-RAN approval. In the event that O-RAN Alliance decides to modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +This document provides common terminology for slicing, an overview of slicing activities in different SDOs (3GPP, ETSI, ONAP, GSMA, etc.) and provides the high level view of O-RAN slicing framework and architecture along with different deployment options. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 16. + +[1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications” + +[2] 3GPP TS 23.501: “System Architecture for the 5G System”, Release 16, December 2019 + +[3] 3GPP TR 28.801: “Study on management and orchestration of network slicing for next generation network”, Release 15, January 2018. + +[4] 3GPP TS 28.530: “Aspects; Management and orchestration; Concepts, use cases and requirements”, Release 16, January 2020. + +[5] 3GPP TS 28.541: “Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3”, Release 16, January 2020. + +[6] 3GPP TS 38.300: “NR and NG-RAN Overall Description”, Release 16, January 2020. + +- [7] ETSI GR NFV-EVE 012: “Report on Network Slicing Support with ETSI NFV Architecture Framework”, Release 3, December 2017. +- [8] ETSI GS NFV-IFA 008: “Ve-Vnfm reference point - Interface and Information Model Specification”, Release 2, February 2018. +- [9] ETSI GS NFV-IFA 013: “Os-Ma-Nfvo reference point - Interface and Information Model Specification”, Release 2, February 2018. +- [10] GSMA: “An Introduction to 5G Network Slicing”, 2017. +- [11] GSMA: “From Vertical Industry Requirements to Network Slice Characteristics”, August 2018. +- [12] GSMA: “Network Slicing, Use Case Requirements”, April 2018. +- [13] GSMA: “Generic Network Slice Template”, Release 2, October 2019 +- [14] ETSI GS ZSM 003: “Zero-touch Network and Service Management (ZSM); End to end management and orchestration of network slicing”. + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [1]. + +**A1:** Interface between non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**E2:** Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. + +**FCAPS:** Fault, Configuration, Accounting, Performance, Security. + +**Intents:** A declarative policy to steer or guide the behaviour of RAN functions, allowing the RAN function to calculate the optimal result to achieve stated objective. + +**near-RT RIC:** O-RAN near-real-time RAN Intelligent Controller: a logical function that enables near-real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. + +**non-RT RIC:** O-RAN non-real-time RAN Intelligent Controller: a logical function that enables non-real-time control and optimization of RAN elements and resources, AI/ML workflow including model training and updates, and policy-based guidance of applications/features in near-RT RIC. + +**NMS:** A Network Management System. + +**O-CU:** O-RAN Central Unit + +**O-CU-CP:** O-RAN Central Unit – Control Plane: a logical node hosting the RRC and the control plane part of the PDCP protocol. + +**O-CU-UP:** O-RAN Central Unit – User Plane: a logical node hosting the user plane part of the PDCP protocol and the SDAP protocol. + +**O-DU:** O-RAN Distributed Unit: a logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. + +**O-RU:** O-RAN Radio Unit: a logical node hosting Low-PHY layer and RF processing based on a lower layer functional split. This is similar to 3GPP’s “TRP” or “RRH” but more specific in including the Low-PHY layer (FFT/iFFT, PRACH extraction). + +**O1:** Interface between management entities (NMS/EMS/MANO) and O-RAN managed elements, for operation and management, by which FCAPS management, Software management, File management shall be achieved. + +**RAN:** Generally referred as Radio Access Network. In terms of this document, any component below near-RT RIC per O-RAN architecture, including O-CU/O-DU/O-RU. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [1]. + +| | | +|-------------|----------------------------------------------------------------------| +| eNB | eNodeB (applies to LTE) | +| gNB | gNodeB (applies to NR) | +| KPI | Key Performance Indicator | +| KQI | Key Quality Indicator | +| Near-RT RIC | Near-RT RIC | +| Non-RT RIC | Non-Real-Time RIC | +| NS | Network Service | +| O-CU | O-RAN Central Unit | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| PNF | Physical Network Function | +| PRB | Physical Resource Block | +| RIC | O-RAN RAN Intelligent Controller | +| RRM | Radio Resource Management | +| SDO | Standards Developing Organizations (For ex: 3GPP, ETSI, ONAP, O-RAN) | +| SMO | Service and Management Orchestration | +| VNF | Virtual Network Function | +| NSD | NFV Network Service Descriptors | +| NST | Network Slice Templates | + +# --- Chapter 2 Objective + +The current document aims to define the common terminology for slicing, captures slicing activities in different SDOs (3GPP, ETSI, ONAP, GSMA, etc.) and provides the high level view of O-RAN slicing framework and architecture, with the purpose of helping identify requirements for O-RAN defined interfaces and functions, eventually leading to formal drafting of interface specifications. + +# Chapter 3 Common Terminology + +In this chapter, it is aimed to list slice specific definitions to agree on a common terminology. + +**Network slice instance:** a set of network functions and the resources for these network functions which are arranged and configured, forming a complete logical network to meet certain network characteristics. [3] + +**Network slice subnet instance:** a set of network functions and the resources for these network functions which are arranged and configured to form a logical network. [3] + +**Network slice subnet template:** description of the structure (and contained components) and configuration of the network slice subnet. [3] + +**Network slice template:** description of the structure (and contained components) and configuration of a network slice. [3] + +**Physical resource isolation:** regime of resource management when a physical resource used by one network slice instance cannot be shared with another network slice instance. [3] + +# Chapter 4 Slicing in SDOs + +## 4.1 Slicing in 3GPP + +### Architecture Including Network Slicing + +Network slicing concept is considered as one of the key feature of 5G networks. Service-based 5G architecture including network slicing is defined in 3GPP TS 23.501 [2]. Figure 4.1-1 represents the non-roaming reference architecture and interfaces utilised in control plane. + +![Figure 4.1-1: Reference architecture diagram showing the 5G service-based architecture. The diagram illustrates the control plane interfaces between various network functions. At the top, a row of service-based interfaces (Nnssf, Nnef, Nnrf, Npcf, Nudm, Naf) connects to a row of network functions (NSSF, NEF, NRF, PCF, UDM, AF). Below these, another row of interfaces (Nausf, Namf, Nsmf) connects to a row of network functions (AUSF, AMF, SMF, SCP). The bottom row shows the data plane components: UE, (R)AN, UPF, and DN. The interfaces between these components are labeled N1 (UE to (R)AN), N2 ((R)AN to AMF), N3 ((R)AN to UPF), N4 (SMF to UPF), N6 (UPF to DN), and N9 (UPF to UPF).](23e6da2f6f6826696020dce4f14fdfe5_img.jpg) + +Figure 4.1-1: Reference architecture diagram showing the 5G service-based architecture. The diagram illustrates the control plane interfaces between various network functions. At the top, a row of service-based interfaces (Nnssf, Nnef, Nnrf, Npcf, Nudm, Naf) connects to a row of network functions (NSSF, NEF, NRF, PCF, UDM, AF). Below these, another row of interfaces (Nausf, Namf, Nsmf) connects to a row of network functions (AUSF, AMF, SMF, SCP). The bottom row shows the data plane components: UE, (R)AN, UPF, and DN. The interfaces between these components are labeled N1 (UE to (R)AN), N2 ((R)AN to AMF), N3 ((R)AN to UPF), N4 (SMF to UPF), N6 (UPF to DN), and N9 (UPF to UPF). + +Figure 4.1-1: Reference architecture + +### Network Slice Identification and Service Types + +A network slice is always defined with RAN part and CN part in a PLMN (see Clause 5.15.1 in [2]). The network slicing support is based on the principle that flows of the different slices handled by different PDU sessions. Granularity of slice awareness is in PDU session level (see Clause 16.3.1 in [6]). + +S-NSSAI is a unique identifier for each network slice. NSSAI (Network Slice Selection Assistance Information) includes one or a list of s-NSSAIs which is a combination of mandatory SST (Slice/Service Type) and an optional SD (Slice Differentiator). The operator may choose to serve same Slice/Service Type but using different s-NSSAIs in case of serving same features to different group of users. + +To support roaming use cases more efficiently, some SST values are standardised for the most common service types as shown in the Table 4.1-2 defined as in 3GPP TS 23.501 [2]. + +| Slice/Service type | SST value | Characteristics | +|--------------------|-----------|--------------------------------------------------------------------------------| +| eMBB | 1 | Slice suitable for the handling of 5G enhanced Mobile Broadband. | +| URLLC | 2 | Slice suitable for the handling of ultra- reliable low latency communications. | +| MIoT | 3 | Slice suitable for the handling of massive IoT. | +| V2X | 4 | Slice suitable for the handling of V2X services. | + +Table 4.1-2: Standardized SST values + +### Key Principles of Network Slicing + +A single UE can connect one or more Network Slice instances simultaneously. The maximum number of simultaneous connection is 8 per UE. If UE has multiple simultaneous connections to the different slices, only one signalling connection is used. + +5G QoS model is based on QoS Flows. GBR QoS flows require guaranteed flow bit rate. Non-GBR QoS flows, by contrast, do not require guaranteed flow bit rate. QoS differentiation is supported within a network slice. + +NG-RAN should support resource management between slices. SLA is provided between slices. Multiple slices could be supported on a single RAN and resource isolation is maintained between slices. Shared resources should be managed by RRM policies or other mechanisms to prevent SLA violations for other slices. + +Slice availability depends on the deployment scenario. Some slices might be offered globally while some others might be only in a local area. + +### Selection of a Network Slice + +AMF selection procedure is made based on NSSAI or Temp ID. NSSAI is used when UE does not have Temp ID. Otherwise, RAN uses the NSSAI reported by UE during initial access procedure to select appropriate AMF. If both of them is not available, RAN routes UE to a default AMF. + +After RRC connection and AMF Selection are completed successfully, selected AMF sends Initial Context Setup Request message to RAN to complete UE context. This message includes allowed NSSAI, s-NSSAI for each PDU session. When required resources and policies for the selected slice(s) are ready, RAN side sends an Initial Context Setup Response message to AMF 3GPP TS 38.300 [6]. + +### Management and Orchestration of Network Slicing + +Network slice is a logical network that provides specific network capabilities and network characteristics. There are some aspects that a network slice includes. A deployed network slice forms a Network Slice Instance (NSI). An NSI has all the physical and logical resources and the functionalities to serve a business use case. The NSI contains Core Part and Access Part. To create an NSI, configurations and policies are required for each instance. The NSI lifecycle includes commissioning, operation and decommissioning phases as shown in Fig 4.1-2. + +![Figure 4.1-2: NSI lifecycle diagram. The diagram shows the lifecycle of a Network Slice Instance (NSI) across four main phases: Preparation, Commissioning, Operation, and Decommissioning. Preparation includes Design, On-boarding, and Network environment preparation. Commissioning includes Creation. Operation includes Activation, Supervision, Reporting, De-activation, and Modification. Decommissioning includes Termination. Arrows indicate the flow from Preparation to Commissioning, then to Operation, and finally to Decommissioning. Within the Operation phase, Supervision and Reporting are linked to Modification, which in turn links to De-activation.](b04f8982ef1411efba3ad1656bbef224_img.jpg) + +``` + +graph LR + subgraph Preparation + Design --> OnBoarding[On-boarding] + NetEnv[Network environment preparation] + end + subgraph Commissioning + Creation + end + subgraph Operation + Activation + subgraph Ops + Supervision <--> Reporting + Ops <--> Modification + end + Deactivation + end + subgraph Decommissioning + Termination + end + + Preparation --> Commissioning + Commissioning --> Operation + Operation --> Decommissioning + +``` + +Figure 4.1-2: NSI lifecycle diagram. The diagram shows the lifecycle of a Network Slice Instance (NSI) across four main phases: Preparation, Commissioning, Operation, and Decommissioning. Preparation includes Design, On-boarding, and Network environment preparation. Commissioning includes Creation. Operation includes Activation, Supervision, Reporting, De-activation, and Modification. Decommissioning includes Termination. Arrows indicate the flow from Preparation to Commissioning, then to Operation, and finally to Decommissioning. Within the Operation phase, Supervision and Reporting are linked to Modification, which in turn links to De-activation. + +Figure 4.1-2: NSI lifecycle + +In the preparation phase NSI does not exist and necessary preparations are handled, such as network slice design, capacity planning and on-boarding. Commissioning phase includes the creation of the NSI where all needed resources are allocated and configured per slice requirements. Operation phase is the state that NSI is operating and supporting services to the specified types. In the activation step, any action required to make NSI active is included. Supervision, reporting and modification steps are involved in operation phase. To illustrate, KPI reporting, reconfiguration of NSI or scaling are used + +in these phases. Decommissioning phase involves termination of the NSI and releasing of the resources assigned to it (see Clause 4.3.1 in [4]). + +### Network Resource Model and RRM Slice Policies + +3GPP TS 28.541 [5] has introduced the Information Model in the Network Resource Model (NRM) to fulfill management and orchestration of 5G networks. Regarding the network slicing feature modeling at the NRCelCU level, the model basically lists the s-NSSAI(s) supported in the cell and RRM policy to share resources among listed slices. RRMPolicyType attribute is used to describe RRM policy to be applied. + +## 4.2 Slicing in ONAP + +ONAP 5G slicing activity is ongoing in Frankfurt R6 release. ONAP R5 includes the feature of Network Slicing modeling as a prerequisite for Slicing orchestration that is work in progress in R6. The Network Slice model leverages the shared service/resource approach that is essential for modeling the network slice where VNF's/PNF's may be shared by several slices. + +The shared service approach is similar to ETSI NFV nested services approach, so its TOSCA implementation may be easily translated into Network Service descriptors defined by the ETSI NFV-SOL001 specification for TOSCA based NFV descriptors. + +The graphical representation of the example of modelling the eMBB Network Slice having 3 slice segments (RAN, transport and core) is shown below in Figure 4.2-1. + +![Figure 4.2-1: Example model of eMBB Network Slice. The diagram shows a hierarchical structure of nested boxes representing Network Services (NS). The outermost box is 'eMBB SVC'. Inside it is 'eMBB-NS', which has a properties box: Properties: TAs: All, Latency: 30ms, Mobility: fully mobility, resourceSharing: shared. Inside 'eMBB-NS' is 'eMBB-NSS'. 'eMBB-NSS' contains three main sections: '5G-RAN-NSS', 'TRANS-NSS', and '5GC-NSS'. '5G-RAN-NSS' contains 'VL' (VNF), 'CU-CP' (VNF), 'DU' (PNF), and 'CU-UP' (VNF). 'TRANS-NSS' contains 'TN' (Transport Network). '5GC-NSS' contains 'VL' (VNF), '5GC-CP-SVC' (VNF), and '5GC-UP-SVC' (VNF). A legend on the right defines the symbols: dashed box for PNF, circle for Transport Network, rectangle for VNF, yellow border for Shared, and blue border for Dedicated.](7ba19f20df08acb640a7aea77c3ddca1_img.jpg) + +Figure 4.2-1: Example model of eMBB Network Slice. The diagram shows a hierarchical structure of nested boxes representing Network Services (NS). The outermost box is 'eMBB SVC'. Inside it is 'eMBB-NS', which has a properties box: Properties: TAs: All, Latency: 30ms, Mobility: fully mobility, resourceSharing: shared. Inside 'eMBB-NS' is 'eMBB-NSS'. 'eMBB-NSS' contains three main sections: '5G-RAN-NSS', 'TRANS-NSS', and '5GC-NSS'. '5G-RAN-NSS' contains 'VL' (VNF), 'CU-CP' (VNF), 'DU' (PNF), and 'CU-UP' (VNF). 'TRANS-NSS' contains 'TN' (Transport Network). '5GC-NSS' contains 'VL' (VNF), '5GC-CP-SVC' (VNF), and '5GC-UP-SVC' (VNF). A legend on the right defines the symbols: dashed box for PNF, circle for Transport Network, rectangle for VNF, yellow border for Shared, and blue border for Dedicated. + +Figure 4.2-1: Example model of eMBB Network Slice + +Nested Network Service is the approach for shared resources (VNF/NS) + +- Nested network service TOSCA implementation in ETSI NFV-SOL001 +- PNFD may be part of Nested Service + +Sharing of Network Slice resources (PNF's and VNF's) for ONAP release 6 is proposed using Nested services approach (based on work done for Release 5) including wrapping PNFs/VNF's within Network Services and defining operations and properties on Service level. The Network slicing orchestration in ONAP R6 will include assigning workflows to the operations. + +Following this approach, the topology model for O-RAN segment would be as shown below in Figure 4.2-2: + +![Figure 4.2-2: High level O-RAN topology model. The diagram shows a 5G RAN network architecture. A dashed purple box labeled '5G RAN' contains a DU (1-N), CU-UP (1-N), CU-CP (1), and RIC (1). The DU is connected to the CU-UP and CU-CP via F1U and F1C interfaces. The CU-UP is connected to the CU-CP via E1 and F1C interfaces. The RIC is connected to the CU-CP via A1 and F1C interfaces. The diagram also shows external components: PNF (Public Network Function) connected to the DU, VNF (Virtual Network Function) connected to the CU-CP, and NSD (Network Service Description) connected to the RIC. A legend on the left defines the symbols: EP_F1U (Application signaling end points), F1U (Application layer signaling link), MnS (3GPP management services - O-RAN OAM), and A1 (O-RAN defined A1 Interface).](e2473eccff9a2db043bbfa17e69afd0a_img.jpg) + +Figure 4.2-2: High level O-RAN topology model. The diagram shows a 5G RAN network architecture. A dashed purple box labeled '5G RAN' contains a DU (1-N), CU-UP (1-N), CU-CP (1), and RIC (1). The DU is connected to the CU-UP and CU-CP via F1U and F1C interfaces. The CU-UP is connected to the CU-CP via E1 and F1C interfaces. The RIC is connected to the CU-CP via A1 and F1C interfaces. The diagram also shows external components: PNF (Public Network Function) connected to the DU, VNF (Virtual Network Function) connected to the CU-CP, and NSD (Network Service Description) connected to the RIC. A legend on the left defines the symbols: EP\_F1U (Application signaling end points), F1U (Application layer signaling link), MnS (3GPP management services - O-RAN OAM), and A1 (O-RAN defined A1 Interface). + +Figure 4.2-2: High level O-RAN topology model + +## 4.3 Slicing Orchestration in 3GPP SA5 and ETSI NFV MANO + +According to ETSI NFV Network Slicing Report [7], network slicing has been defined by different SDOs, there is no common definition for network slicing. Therefore, understanding of network slicing is different from each other. Nonetheless, the report does not introduce use cases or features but analyses network slicing in external SDOs. In this report, how these external use cases should be mapped to NFV and the ETSI NFV architecture is explained. + +As stated in 3GPP TR 28.801 [3], a network slice may contain one or more network slice subnets and each of them includes one or more network functions. VNFs and PNFs are managed as these network functions in the ETSI NFV architecture. Related to network slicing management, there are three different management functions identified in 3GPP TR 28.801 [3]: + +- Communication Service Management Function (CSMF): translates the communication service related requirement to network slice related requirements. +- Network Slice Management Function (NSMF): responsible for management and orchestration of NSI. Provides communication with the Network Slice Subnet Management Function (NSSMF) and Communication Service Management Function. +- Network Slice Subnet Management Function (NSSMF): responsible for management and orchestration of NSSI. + +As shown in the Figure 4.3-1, Os-Ma-nfvo reference point is used for interaction between 3GPP slice management functions and NFVO. Similarly, Ve-Vnfm-em reference point is used for exchanges between NFMF and VNF Manager. Further analysis is required on these reference points to apply deployment scenarios including 3GPP network slicing related management functions and NFV-MANO. Further details are available in ETSI GS NFV-IFA 008 [8] and ETSI GS NFV-IFA 013 [9]. + +![Figure 4.3-1: Network slice management in an NFV framework. The diagram shows a hierarchical structure. At the top is a box labeled '3GPP Slice Related Management Functions' containing 'CSMF', 'NSMF', and 'NSSMF'. This box connects to 'NFVO' via 'Os-Ma-nfvo'. Below the top box is 'NFMF', which connects to 'NFVO' via 'Ve-Vnfm-em' and to 'PNF' and 'VNF' via 'Ve-Vnfm-vnf'. 'NFVO' also connects to 'VNFM' and 'VIM'. 'VNFM' connects to 'VIM'.](3bb1468d23787cbe05312e5d6b0106b8_img.jpg) + +Figure 4.3-1: Network slice management in an NFV framework. The diagram shows a hierarchical structure. At the top is a box labeled '3GPP Slice Related Management Functions' containing 'CSMF', 'NSMF', and 'NSSMF'. This box connects to 'NFVO' via 'Os-Ma-nfvo'. Below the top box is 'NFMF', which connects to 'NFVO' via 'Ve-Vnfm-em' and to 'PNF' and 'VNF' via 'Ve-Vnfm-vnf'. 'NFVO' also connects to 'VNFM' and 'VIM'. 'VNFM' connects to 'VIM'. + +Figure 4.3-1: Network slice management in an NFV framework + +Figure 4.3-2 shows an example of a 5G network realized by an end-to-end network slice, consisting of network slice subnet #1 for 5G core networks and network slice subnet #2 for 5G radio networks (see Clause 4.1.3 in TS 28.530 [4]). + +![Figure 4.3-2: 5G network with network slicing. The diagram is divided into 'Radio networks' and 'Core networks'. In the 'Radio networks' section, 'O-RU #1' connects to 'O-DU', which connects to 'O-CU-UP' and 'O-CU-CP'. 'O-CU-UP' and 'O-CU-CP' are part of 'Network slice subnet #2'. In the 'Core networks' section, 'SMF' connects to 'UPF #1' and 'AMF'. 'UPF #1' and 'AMF' are part of 'Network slice subnet #1'. A cloud labeled 'SP #1 (e.g. IoT)' connects to 'UPF #1'. Arrows indicate connections between 'O-CU-UP' and 'SMF', 'O-CU-CP' and 'AMF', and 'UPF #1' and 'AMF'. A dashed blue oval encloses the entire network slice, labeled 'Network slice #1 (Network slice subnet #3)'.](ba15e62707a1e66c4dfbaea7645f5e05_img.jpg) + +Figure 4.3-2: 5G network with network slicing. The diagram is divided into 'Radio networks' and 'Core networks'. In the 'Radio networks' section, 'O-RU #1' connects to 'O-DU', which connects to 'O-CU-UP' and 'O-CU-CP'. 'O-CU-UP' and 'O-CU-CP' are part of 'Network slice subnet #2'. In the 'Core networks' section, 'SMF' connects to 'UPF #1' and 'AMF'. 'UPF #1' and 'AMF' are part of 'Network slice subnet #1'. A cloud labeled 'SP #1 (e.g. IoT)' connects to 'UPF #1'. Arrows indicate connections between 'O-CU-UP' and 'SMF', 'O-CU-CP' and 'AMF', and 'UPF #1' and 'AMF'. A dashed blue oval encloses the entire network slice, labeled 'Network slice #1 (Network slice subnet #3)'. + +Figure 4.3-2: 5G network with network slicing + +The following diagram (Figure 4.3-3) shows the interaction between 3GPP and ETSI NFV to create a network slice subnet instance for RAN network functions. + +![Sequence diagram showing the high level view of network slice subnet instance creation between NSMF, NFMF, NSSMF, NFVO, and VNFM.](4528fe480fbe9fc9b4a28c6416c43206_img.jpg) + +``` + +sequenceDiagram + participant NSMF + participant NFMF + participant NSSMF + participant NFVO + participant VNFM + + NSMF->>NSSMF: 1. Allocate a network slice subnet instance for RAN network functions + NSSMF->>NFVO: 2. Instantiate a NS, containing VNFs (O-CU and O-DU) and PNF (O-RU) + NFVO->>VNFM: 3. instantiate VNFs (O-CU and O-DU) + VNFM-->>NFMF: 4. notification of instantiation of VNFs (O-CU and O-DU) + VNFM-->>NFVO: 5. VNFs have been instantiated + NFVO-->>NSSMF: 6 notification of successful NS instantiation + NSSMF-->>NSMF: 7. notifications of successful network slice subnet creation + +``` + +Sequence diagram showing the high level view of network slice subnet instance creation between NSMF, NFMF, NSSMF, NFVO, and VNFM. + +Figure 4.3-3: High level view of network slice subnet instance creation + +1. NSMF sends request to allocate a network slice subnet instance for RAN network functions, e.g. O-CU, O-DU, and O-RU. +2. NSSMF decides to instantiate a Network Service (NS) instance for a new network slice subnet instance. +3. NFVO sends request to instantiate the VNFs for O-CU, O-DU. +4. VNFM instantiates VNFs and notifies NFMF that VNFs have been instantiated. +5. VNFM responds to NFVO informing that VNFs have been instantiated. +6. NFVO notify NSSMF that NS has been instantiated. +7. NSSMF responds to NSMF with status equals to successful for the operation of network slice subnet instance creation. + +## 4.4 Slicing in ETSI ZSM + +The management services (MnSs) for end-to-end network slicing are provided by a set of management domains (MDs). Including that for network slicing defined by 3GPP SA5 and that for NFV defined by ETSI NFV, provides various MnSs as shown in Figure 4.4-1 [14]. + +![Figure 4.4-1: Example of MDs to support network slicing using NFV. The diagram shows a hierarchical architecture. At the top is the 'Digital Storefront (Automated Customer & Business Management)'. Below it is the 'ZSM' (Zero-touch Service Management) layer, which contains the 'E2E Service Management Domain' (with 'Serv-Orch (NS/NSS Mns)') and 'Common Data Services'. The ZSM layer is connected to an 'Inter-domain Integration Fabric'. Below the fabric are several 'Management Domains for Network Slice Subnet(s)'. These include: 'Management Domain for Network Slice Subnet(s) in Transport Network (Transport management domain)' (with 'Dom-Orch (NSS Mns)' and 'Conf-Mgmt'); 'Management Domain for Network Slice Subnet(s) in Core Network (Core management domain)' (with 'Dom-Orch (NSS Mns)' and 'Conf-Mgmt (NF Mns)'); 'Management Domain for Network Slice Subnet(s) in RAN (Radio access management domain)' (with 'Dom-Orch (NSS Mns)' and 'Conf-Mgmt (NF Mns)'); 'Management Domain for NFV (Virtualization management domain)' (with 'Dom-Orch (NFVO)', 'Conf-Mgmt (VNFM)', and 'VIM'); and 'Other Management Domains'. These domains are connected to an 'Integration Fabric' at the bottom, which is linked to 'Physical', 'Virtual', and 'Cloud' resources.](5755ffd47b0782111fe6a2d99e72764e_img.jpg) + +Figure 4.4-1: Example of MDs to support network slicing using NFV. The diagram shows a hierarchical architecture. At the top is the 'Digital Storefront (Automated Customer & Business Management)'. Below it is the 'ZSM' (Zero-touch Service Management) layer, which contains the 'E2E Service Management Domain' (with 'Serv-Orch (NS/NSS Mns)') and 'Common Data Services'. The ZSM layer is connected to an 'Inter-domain Integration Fabric'. Below the fabric are several 'Management Domains for Network Slice Subnet(s)'. These include: 'Management Domain for Network Slice Subnet(s) in Transport Network (Transport management domain)' (with 'Dom-Orch (NSS Mns)' and 'Conf-Mgmt'); 'Management Domain for Network Slice Subnet(s) in Core Network (Core management domain)' (with 'Dom-Orch (NSS Mns)' and 'Conf-Mgmt (NF Mns)'); 'Management Domain for Network Slice Subnet(s) in RAN (Radio access management domain)' (with 'Dom-Orch (NSS Mns)' and 'Conf-Mgmt (NF Mns)'); 'Management Domain for NFV (Virtualization management domain)' (with 'Dom-Orch (NFVO)', 'Conf-Mgmt (VNFM)', and 'VIM'); and 'Other Management Domains'. These domains are connected to an 'Integration Fabric' at the bottom, which is linked to 'Physical', 'Virtual', and 'Cloud' resources. + +Figure 4.4-1: Example of MDs to support network slicing using NFV + +In this operator deployment example: + +- E2E Service MD provides MnSs for E2E network slices/network slice subnets, e.g. Service Orchestration service (Serv-Orch), which orchestrates the individual network slice subnets (NSSs) provided by Radio Access Network (RAN), Transport Network (TN) and Core Network (CN), and stitches them into a E2E network slice subnet being exposed as a network slice. The MnSs in this MD may also manage NSSs of Data Network (aka. SGI Network) using MD for NFV. It is expected that parts of specifications developed by 3GPP SA5 are re-used for the MnSs in this MD. This MD exposes e.g. management capabilities of E2E network slices (provisioning, performance assurance, fault supervision, etc.). +- MD for NSS in TN provides MnSs for NSSs of TN, e.g. Dom-Orch service. This MD may consume TN resources outside of ZSM supported by e.g. Configuration Management service(s) (Conf-Mgmt). It is expected that parts of specifications developed by e.g. BBF, MEF, IETF and/or ETSI NFV are re-used for the MnSs in this MD. This MD exposes e.g. management capabilities of NSS of TN (provisioning, performance assurance, fault supervision, etc.). +- MD for NSS in RAN provides MnSs for NSSs of RAN, e.g. Dom-Orch service. This MD may consume application level RAN resources (i.e. application part of RAN Network Functions) outside of ZSM supported by e.g. Conf-Mgmt, and it may also consume MnSs for Network Services which include virtualized resources from MD for NFV. It is expected that parts of specifications developed by 3GPP SA5 are re-used for the MnSs in this MD. This MD exposes e.g. management capabilities of NSS of RAN (provisioning, performance assurance, fault supervision, etc.). +- MD for NSS in CN provides MnSs for NSSs of CN, e.g. Dom-Orch service. This MD may consume application level CN resources outside of ZSM (i.e. application part of CN Network Functions) supported by e.g. Conf-Mgmt, and it may also consume MnSs for Network Services which include virtualized resources from MD for NFV. It is expected that parts of specifications developed by 3GPP SA5 are re-used for the MnSs in this MD. This MD exposes e.g. management capabilities of NSS of CN (provisioning, performance assurance, fault supervision, etc.). +- MD for NFV provides MnSs for NFV Network Service(s) (at resource level), e.g. Dom-Orch service (NFV Orchestrator). This MD may also have Conf-Mgmt (VNF Manager) and MnSs for managing compute/network/storage resources (Virtualized Infrastructure Manager). It is expected that parts of specifications developed by ETSI NFV are re-used for the MnSs in this MD. This MD exposes e.g. management capabilities related to NFV Network Services (Create/Read/Update/Delete of the Network Services, on-boarding of catalogues for those, etc.). + +Using the operator deployment scenario in Figure 4.4-1, a service over an E2E network slice instance comprising of RAN access + virtualized application can be deployed. Figure 4.4-2 describes the particular instance of service consumption across the domains. + +![Diagram of E2E Service Management Domain architecture](e0928093b776691a1c6c70735492ac2a_img.jpg) + +``` + +graph TD + E2E[E2E Service Management Domain] + RAN[Radio access management Domain +(with virtualized RAN) +(NSSMF)] + NFVO[Virtualization management domain +(NFVO)] + Core[Core management domain +(with VNFs) +(NSSMF)] + Transport[Transport management domain] + + E2E --- RAN + E2E --- NFVO + E2E --- Core + E2E --- Transport + RAN --- NFVO + NFVO --- Core + Core --- Transport + +``` + +The diagram illustrates the E2E Service Management Domain architecture. At the top is a large box labeled "E2E Service Management Domain". Below it, four smaller boxes are arranged horizontally: "Radio access management Domain (with virtualized RAN) (NSSMF)", "Virtualization management domain (NFVO)", "Core management domain (with VNFs) (NSSMF)", and "Transport management domain". Lines connect the top box to each of the four bottom boxes. Additionally, lines connect the bottom boxes in sequence from left to right: Radio access to Virtualization, Virtualization to Core, and Core to Transport. + +Diagram of E2E Service Management Domain architecture + +Figure 4.4-2: Example management services' consumption to show E2E slice deployment. + +The steps of deployment are: + +- 1) The E2E service breaks up the E2E network slicing deployment requests into + - a) Part of the E2E network slice (for fixed users and Transport) + 3GPP Core Part of the E2E network slice (for Mobile users) + 3GPP RAN part of the E2E network slice + application service (Virtualized) +- 2) A part of the E2E network slice is handed over to the TN management domain using the appropriate management services exposed by the transport management domain. +- 3) The 3GPP core part (CP: AMF/SMF, UPF, N1,N6) goes to the core management system + - a) The core management domain requests the connectivity (N1, N6) to the transport management domain + - b) The Core management domain hands over the VNFs (AMF/SMF, UPF...) to the virtualization management domain +- 4) The access part goes to radio access service management domain + - a) The radio access management domain uses the management services of the virtualization management domain to deploy the virtualized RAN part +- 5) The virtualized application AS is handed over to be deployed by the virtualization management system. + +## 4.5 Slicing in GSMA + +GSMA published a document [10] which aims to provide an introduction to network slicing functionality. It shows how network slicing can be used by business customers. Business customers are referred as users of the 5G services which could be enterprises, specialized industries or individuals. Network slicing is analyzed from the business customers' point of view in addition to set of use cases. + +It is highlighted that different business customers has various requirements like ultra-reliable services, ultra-high-bandwidth communication or extremely low latency. Running multiple logical networks on a common physical infrastructure is enabled by network slicing. Network slice contained 5G networks allow business customers to have connectivity having different business requirements which are governed by SLAs. + +1 Network slicing provides ability to customize capabilities and functionality of the mobile network offered to business +2 customers. Customized services are classified as Network Connection Service and Network Resource Service. The first +3 one indicates the connectivity functionalities of the customer e.g. near real-time latency, guaranteed SLA, seamless +4 mobility and energy efficiency. The second one describes the case that customers are granted access to the operator +5 network resources to run their proprietary applications. In addition to network resource services, the network is able to +6 provide additional services i.e. big data analytics, cloud computing, edge computing and positioning. + +7 +8 GSMA lists some use cases for the business customers to underline potential of network slicing. Industry sectors including +9 automotive, logistic, healthcare, government are indicated as potential application of the network slicing. + +10 +11 As the successor of the previous document, GSMA conducted a study on the service requirements expressed by various +12 business customers. In addition to detailed analysis of the service requirements, recommendations for the industry has +13 been provided. Finally, a generic slice template has been introduced and all the attributes a network slice could have, has +14 been discussed [12]. Generic Slice Template (GST) lists set of attributes with names and units that characterise a network +15 slice (e.g. throughput, supported functionalities). GST categorises the attributes into character attributes and scalability +16 attributes. Former defines generic slice attributes independent from the NSC and NSP (e.g. latency, throughput), while +17 latter provides information about scalability of the slice e.g. number of terminals, area of the service. + +18 Another concept defined to represent network slices with a common language is Network Slice Type (NEST). The NEST +19 is a GST filled with proper values based on a specific business use case. Moreover, NEST is the input for the network +20 slice preparation phase which leads to service profile definition in 3GPP. + +21 +22 GSMA Network Slicing Taskforce (GSMA-NEST) has two main objectives which are defining the GST [13] and +23 identifying set of slices whose characteristics are accepted by the industry. GSMA-NEST aims to deliver NESTs with +24 industry approved slice characteristics which could be used by the operators [11]. +25 + +# Chapter 5 O-RAN Slicing Framework + +## 5.1 O-RAN Slicing Architecture + +### 5.1.1 Non-RT RIC + +The fundamental role of the Non-RT RIC in O-RAN architecture is to apply AI/ML based algorithms to provide innovative RAN use cases. Hence, Non-RT RIC is a key component to allow advanced RAN slicing technology to be applied in O-RAN framework. For this purpose, Non-RT RIC should be aware of RAN slices and related slice properties/configurations as well as slice performance metrics to actively assist slice assurance through optimization methods, including AI/ML models. + +To generate AI/ML models to be deployed in the Near-RT RIC, Non-RT RIC retrieves slice specific PMs and configuration parameters of the slices and optionally external enrichment information from external servers. Complex problems for Near-RT RIC e.g. applying RRM policies can be tackled by learning capabilities of AI/ML. Training models enable non-real-time optimization of the slice specific parameters over O1 interface. Moreover, these performance, configuration and other data are used to assist Near-RT RIC to provide dynamic slice optimization. Applying dynamic slice optimization in the Near-RT RIC is used to prevent SLA violations between the slices. + +### 5.1.2 Near-RT RIC + +Near-RT RIC enables xApps to control RAN elements and their resources through the E2 interface in near real-time (sub second). Similar to Non-RT RIC, Near-RT RIC xApps should be aware of RAN slices and can utilize slice aware algorithms for slice SLA assurance purposes. Once the slices are up and running, slice specific PMs from E2 nodes will be gathered and sent to Near-RT RIC and Near-RT RIC will use these PMs and the slice configuration data to apply dynamic slice optimization to assure slice SLAs, through E2 interface (to be discussed). + +These dynamic slice optimization algorithms can be built into the Near-RT RIC, can be guided from Non-RT RIC through A1 policies, or can be sent down as AI/ML models from Non-RT RIC. + +### 5.1.3 O-RAN Central Unit (O-CU) + +In order to apply RAN slicing in O-RAN framework, both O-CU and O-DU needs to support slicing features as defined by 3GPP. Furthermore slicing can be enhanced with the assistance of O-RAN specific Near-RT RIC dynamic slice optimization through E2 interface. + +O-CU is the O-RAN entity which runs the upper layer protocols of the RAN stack, such as Radio Resource Management. Since RRM is responsible for managing resources, and in case of slicing – the allocation of resources between slices, O-CU needs to execute slice specific resource allocation strategies and drive O-DU(s) similarly. O-CU will interact with Near-RT RIC to provide slice specific PMs as well as getting dynamic guidance through E2 interface. + +### 5.1.4 O-RAN Distributed Unit (O-DU) + +O-DU is the O-RAN entity which runs the lower layer protocols of the RAN stack, including MAC layer which is the layer that schedules Physical Resource Blocks to UEs. As part of slicing, MAC layer needs to allocate PRBs according to the RRM strategies provided by the Operator and slice management entities. O-DU will receive the slice configuration + +parameters from O1 interface, and dynamic slice optimization guidance from RIC through E2 interface and will provide slice specific PMs through O1 interface to SMO and E2 interface to Near-RT RIC. + +### 5.1.5 A1 Impact + +A1 interface will be used to support policy based guidance for slicing use cases, such as SLA assurance. In addition to policy guidance towards Near-RT RIC, Non-RT RIC should be able to receive feedback related to deployed policies over A1 interface. In case of external data enrichment, Non-RT RIC should be able to transfer slice specific enrichment data to Near-RT RIC over A1 interface as well. + +### 5.1.6 E2 Impact + +E2 interface will be used to drive E2 nodes' slice configuration and behaviour, such as slice based radio resource allocations, scheduling policies, and configuration policies that may affect performance characteristics of the corresponding network slice. Near-RT RIC should be able to configure and receive slice specific performance data from the E2 nodes over the E2 interface for near real-time optimization (as compared to PMs collected over the O1 interface, which is a slower loop). Slice specific PMs can include PRB utilization, average delay and DRB related measurements that are already defined in 3GPP. However, E2SM(s) can be extended to support non-3GPP slice specific PM collection so that policy control algorithms running on the Near-RT RIC are improved to meet the slice SLA requirements. + +### 5.1.7 O1 Impact + +The primary role of O1 interface is to enable slice specific configuration of O-RAN nodes based on the service requirements. 3GPP 28.541 [5] has defined the Information Models to list attributes of the slice profiles with the slice specific requirements, including RRM policy attributes to provide ratio of radio resources to split among the supported slices. In addition to slice specific configuration capabilities, O1 interface is used to gather slice specific performance metrics and fault information from O-RAN Nodes. As extensions to O-RAN specific slicing configuration and performance measurement attributes are defined, these information will be sent over O1 interface as well. + +### 5.1.8 O2 Impact + +O2 is the interface used for life cycle management of virtual O-RAN network functions. In case of network slicing, after the preparation phase, SMO might instantiate necessary O-RAN network functions (such as Near-RT RIC, O-CU-CP, O-CU-UP, O-DU) through instantiation procedures as part of the RAN NSSI creation and provisioning, NSSI modification and NSSI deletion. It is expected that Non-RT RIC is instantiated as part of SMO and does not require any lifecycle management activities. + +# Chapter 6 Deployment Options + +This section provides possible deployment options with respect to network slice management topology and their possible effects on O-RAN slicing architecture. Based on 3GPP specifications Network Slice Management Function (NSMF) and Network Slice Subnet Management Function (NSSMF) are responsible for end-to-end slice management and slice subnet management respectively. Within the scope of O-RAN, RAN slice subnet management function is the primary focus including but not limited to its interactions with the Service Management and Orchestration Framework. Possible architectural impacts of different deployment options are planned to be investigated and captured in O-RAN Slicing Architecture Specification document. + +In the following sub sections, four possible deployment options are presented. Please note that while ETSI based NFVO/VNFM interface types are depicted as examples, depending on SMO type these interfaces and NFVO/VNFM components can be different. As other SMOs (such as ONAP) make progress with RAN slicing, the relevant interfaces can be captured in the next iterations of this document. + +### Option 1 + +In this option, both NSMF and NSSMF are deployed within the SMO. + +![Figure 3: NSMF and NSSMF are deployed within the SMO. The diagram shows a Service Management and Orchestration (SMO) block containing NSMF, RAN NSSMF, NFVO, VNFM, and Non-RT RIC. The SMO is connected to a Near-RT RIC block via interface A1. The Near-RT RIC is connected to O-CU-CP and O-CU-UP blocks via interface E2-cp. O-CU-CP and O-CU-UP are connected to O-DU block via interface F1-C and F1-U respectively. The SMO is also connected to O-DU via interface O1.](a8c57fb53cd9939c015ec95b95c49848_img.jpg) + +``` + +graph TD + subgraph SMO [Service Management and Orchestration] + NSMF + RAN_NSSMF[RAN NSSMF] + NFVO + VNFM + Non_RT_RIC[Non-RT RIC] + RAN_NSSMF -.-|Os-Ma-Nfvo| NFVO + NSMF -.-|Ve-Vnfm-Em| VNFM + end + Near_RT_RIC[Near-RT RIC] + O_CU_CP[O-CU-CP] + O_CU_UP[O-CU-UP] + O_DU[O-DU] + + SMO -.-|A1| Near_RT_RIC + Near_RT_RIC -.-|E2-cp| O_CU_CP + Near_RT_RIC -.-|E2-up| O_CU_UP + O_CU_CP <-->|E1| O_CU_UP + O_CU_CP <-->|F1-C| O_DU + O_CU_UP <-->|F1-U| O_DU + SMO -.-|O1| O_DU + +``` + +Figure 3: NSMF and NSSMF are deployed within the SMO. The diagram shows a Service Management and Orchestration (SMO) block containing NSMF, RAN NSSMF, NFVO, VNFM, and Non-RT RIC. The SMO is connected to a Near-RT RIC block via interface A1. The Near-RT RIC is connected to O-CU-CP and O-CU-UP blocks via interface E2-cp. O-CU-CP and O-CU-UP are connected to O-DU block via interface F1-C and F1-U respectively. The SMO is also connected to O-DU via interface O1. + +Figure 3: NSMF and NSSMF are deployed within the SMO + +### Option 2 + +In this case, both NSMF and NSSMF are deployed outside the SMO. + +![Figure 4: External deployment of NSMF and NSSMF. The diagram shows a Service Management and Orchestration (SMO) block containing NSMF, RAN NSSMF, NFVO, Non-RT RIC, NFMF, and VNFM. External components include Near-RT RIC, O-CU-CP, O-CU-UP, and O-DU. Interconnections are labeled: O1 (SMO to Near-RT RIC), A1 (Non-RT RIC to Near-RT RIC), E2-cp (Near-RT RIC to O-CU-CP), E2-up (Near-RT RIC to O-CU-UP), E1 (O-CU-CP to O-CU-UP), F1-C (O-CU-CP to O-DU), and F1-U (O-CU-UP to O-DU).](012c78dfb8458b18fc0dd72fc7078e28_img.jpg) + +Figure 4: External deployment of NSMF and NSSMF. The diagram shows a Service Management and Orchestration (SMO) block containing NSMF, RAN NSSMF, NFVO, Non-RT RIC, NFMF, and VNFM. External components include Near-RT RIC, O-CU-CP, O-CU-UP, and O-DU. Interconnections are labeled: O1 (SMO to Near-RT RIC), A1 (Non-RT RIC to Near-RT RIC), E2-cp (Near-RT RIC to O-CU-CP), E2-up (Near-RT RIC to O-CU-UP), E1 (O-CU-CP to O-CU-UP), F1-C (O-CU-CP to O-DU), and F1-U (O-CU-UP to O-DU). + +Figure 4: External deployment of NSMF and NSSMF + +### Option 3 + +In this option, NSMF is placed within SMO. However, NSSMF is deployed outside the SMO. + +![Figure 5: External NSSMF deployment. The diagram shows a Service Management and Orchestration (SMO) block containing NSMF, NFVO, Non-RT RIC, NFMF, and VNFM. RAN NSSMF is located outside the SMO. Interconnections are labeled: O1 (SMO to Near-RT RIC), A1 (Non-RT RIC to Near-RT RIC), E2-cp (Near-RT RIC to O-CU-CP), E2-up (Near-RT RIC to O-CU-UP), E1 (O-CU-CP to O-CU-UP), F1-C (O-CU-CP to O-DU), and F1-U (O-CU-UP to O-DU).](1b43542eb262785f22df8e72fe462a53_img.jpg) + +Figure 5: External NSSMF deployment. The diagram shows a Service Management and Orchestration (SMO) block containing NSMF, NFVO, Non-RT RIC, NFMF, and VNFM. RAN NSSMF is located outside the SMO. Interconnections are labeled: O1 (SMO to Near-RT RIC), A1 (Non-RT RIC to Near-RT RIC), E2-cp (Near-RT RIC to O-CU-CP), E2-up (Near-RT RIC to O-CU-UP), E1 (O-CU-CP to O-CU-UP), F1-C (O-CU-CP to O-DU), and F1-U (O-CU-UP to O-DU). + +Figure 5: External NSSMF deployment + +### Option 4 + +In this case, NSMF is in the outside of SMO while NSSMF is deployed within SMO. + + + +# Annex A (informative): Additional Information + +## A.1 Slicing SDO Mapping Table + +| Areas | 3GPP | ONAP | ETSI OSM | GSMA | ETSI ZSM | +|--------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------|------------------------------------------| +| Use cases and high level requirements | 3GPP TS 22.261 | | | Network Slicing Use Case Requirements

GSMA-NEST (Network Slicing Task Force) | | +| Architectural requirements | 3GPP TS 23.501
3GPP TS 23.502 (Procedures involving slicing)
3GPP TR 28.801 | | | | | +| Management and orchestration | 3GPP TS 28.531
3GPP TS 28.530
3GPP TS 28.541
3GPP TR 28.801 | R4 (Dublin) for Network Slice Model,

R5 (El Alto) for Orchestration of Network Slicing Model | ETSI GS NFV-IFA 014
ETSI GS NFV-IFA 013 (Os-Ma-nfvo)
ETSI GS NFV-IFA 008 (Ve-Vnfm) | | ETSI GS ZSM 002 (Reference Architecture) | +| Slice Configuration | 3GPP TS 28.531
3GPP TS 28.541 | TOSCA based service and network slice modelling | ETSI GS NFV-IFA 014 (Network Service Templates Specification) | NG.116 - Generic Network Slice Template (attributes are listed) | | +| Security aspects of network slicing | 3GPP TR 33.811 | | | | | +| Slice specific Performance Management (PM), KPIs | 3GPP TS 28.552
3GPP TS 28.554 | | | | | +| Fault Management | 3GPP TS 28.801
3GPP TS 28.530
3GPP TS 28.515-517
3GPP TS 32.111
3GPP TS 28.545 (Fault Supervision)
3GPP TS 28.545 | | | | | + +# Annex ZZZ O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +### SECTION 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Portion” means only those specific portions of products (hardware, software or combinations thereof) that implement any O-RAN Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by implementation of a Final Specification (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate an implementation which complies with a Final Specification without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +### SECTION 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +### SECTION 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair, Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Portions; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Portion is incorporated that is not itself part of the Compliant Portion; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing license includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Portions. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under FRAND terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Portions; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Portion is incorporated that is not itself part of the Compliant Portion; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing license includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Portions. + +### SECTION 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of O-RAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +### SECTION 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +### SECTION 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +### SECTION 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. + +O-RAN SPECIFICATIONS ARE PROVIDED “AS IS” WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +### SECTION 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance’s sole discretion. O-RAN Alliance may freely assign this Agreement. + +### SECTION 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +### SECTION 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity’s or association’s agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +### SECTION 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates’ performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +1 +2 In the event that any provision of this Agreement conflicts with governing law or if any provision is held +3 to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions +4 will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and +5 restrictions of this Agreement will remain in full force and effect. + +6 Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of +7 any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or +8 otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or +9 third party beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other +10 instance; rather the same shall be and remain in full force and effect. + +11 +12 .... \ No newline at end of file diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/0d66e1d2186c3a813314836e79806886_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/0d66e1d2186c3a813314836e79806886_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8a6bfc7989296f1e7d6f7eda3b6160fbfa032b51 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/0d66e1d2186c3a813314836e79806886_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:42650a0c30b29cd5fb07f89a93bb4dbbc1c2ce04620c1a9c8c05d41b5495086a +size 217550 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/1b573bfb618887a43d7fba1490155965_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/1b573bfb618887a43d7fba1490155965_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..250ffc78f58127817b87dab324c4c0499e361d92 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/1b573bfb618887a43d7fba1490155965_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1a3f440a68d76f0456263604462599f19bfcdd86ad11406fcf51632a396615e3 +size 75564 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/21f9cff9cf31345d4411ac705209f5c0_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/21f9cff9cf31345d4411ac705209f5c0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aa74331c95972393e0cd1c0b1bf483853eb3df8c --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/21f9cff9cf31345d4411ac705209f5c0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d867a6116d94f7fd58d36e28a22d09cbf19b5c5f3cb99fcd5fcb8f93ef2ad296 +size 286608 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/23b7bd98084ae29576a3d548ca49573d_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/23b7bd98084ae29576a3d548ca49573d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..92210bccec529dd4c7fc2f18ee81226b8320e99b --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/23b7bd98084ae29576a3d548ca49573d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:feb0b9887637ffb6a2a5fd1813053a8cb648b524920871c9c07ab67aaa20ca4d +size 21019 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/2823820877c01e4a704fd2ac0b7997ce_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/2823820877c01e4a704fd2ac0b7997ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ef521064c30c1b9bc4d2be8954b93d44b1fb6dc5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/2823820877c01e4a704fd2ac0b7997ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9da74d26e7ac0e386121b8b39c08667091c846eb75f0ec08e09124fe7b68c64d +size 199775 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/4e1909f0476f5843a5e3c32b56ad681b_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/4e1909f0476f5843a5e3c32b56ad681b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0d3f19945370716c8cebea22eebf3d5988846e83 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/4e1909f0476f5843a5e3c32b56ad681b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a5eb05fb1b1feead9a86c840ddfb78a35fb4a8e6c9a82c19fbd87a33130613c8 +size 39281 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/54cfd211a572ecfbfa807035fac1f52c_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/54cfd211a572ecfbfa807035fac1f52c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7ddc893d6bf3d7075dc6c4cf191f605f5fdd2bfb --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/54cfd211a572ecfbfa807035fac1f52c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c162810a18bbc6eea31330bcc658d5f0dc282e5862782ce6bd79cb3867d0d370 +size 97919 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/8c0cd75df224ed6bd8721c64d5613579_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/8c0cd75df224ed6bd8721c64d5613579_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1d9652e628977e8e2a95f31dfd31a535bf6623c9 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/8c0cd75df224ed6bd8721c64d5613579_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:63a2d1043a814c62deadf99778f97a4ac117d404d9a87fabf19326b31780a648 +size 4543 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/a056fd415f9b8c8fe6a711772f224313_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/a056fd415f9b8c8fe6a711772f224313_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..79cf2db580ff5844c9a1adcd6f0b8e58aa3595e4 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/a056fd415f9b8c8fe6a711772f224313_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:96899df802f60fd0c50fd536a53fe28cd090755753b82fb3660a2d1ceeda85b1 +size 79419 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/a3c0786df44a43752a87efbcea85b67a_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/a3c0786df44a43752a87efbcea85b67a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f7cbae8bccb2ce4ba3b297124933593a96c2b21f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/a3c0786df44a43752a87efbcea85b67a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15f7ec60026a4043199bbc3b89fc1a9b6f6f1aeb760db098e6149698261eb4d5 +size 108223 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/cd840a36a907598ee71b234dff6e5fc4_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/cd840a36a907598ee71b234dff6e5fc4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..763e42c6c2c7cb33a8746c2181ec639df315ddef --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/cd840a36a907598ee71b234dff6e5fc4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:99d40d66d18da0522374327b84af311d664c7876e76a074514d1e8ffae86b62c +size 296482 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d73ac8b8be38faf362b1eaa59fff1f3f167364fb --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3276e59412020445a9dbac9cf2ede064a279427afdcaa0dcf94fa0620d916726 +size 4546 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/dd3739e9566214b1a579a9796e28d627_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/dd3739e9566214b1a579a9796e28d627_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b8a48191d45898e5816d43834b4f96800d485802 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/dd3739e9566214b1a579a9796e28d627_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:41ae292e39ab1fc96a0bf7b3cad9ed2fd2b8e675b889e451ce1d33171b77114e +size 4547 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2d377a7b1ecc3d90d66455a89af93a9d69c05c2 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f53afab4ac078add52c3f0b2a3b8709940df75f38907b6df0bd3e7c4b98620ac +size 4528 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/fd1365e12d5da8a52ee014200a9b6c5e_img.jpg b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/fd1365e12d5da8a52ee014200a9b6c5e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eea7c4c2904268cbd9a7213a55e7db104e839631 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/fd1365e12d5da8a52ee014200a9b6c5e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:925b6bc7c210d6eef925745d71a67f091bb9d00ac0ddec2f86d9c733b6be4975 +size 4549 diff --git a/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/raw.md b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..a8f2c1925824189714b6c3da55dc4553d73aef58 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00/raw.md @@ -0,0 +1,1770 @@ + + +# O-RAN Work Group 1 (Use Cases and Overall Architecture) **Decoupled SMO Architecture** + +Prepared by the O-RAN ALLIANCE e.V. Copyright © 2024 by the O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in the Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. + +Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238 + +VAT ID DE321720189 + +# Contents + +| | | +|-------------------------------------------------------------------------|----| +| List of figures ..... | 4 | +| List of tables ..... | 4 | +| Foreword ..... | 5 | +| Modal verbs terminology ..... | 5 | +| Introduction ..... | 5 | +| 1 Scope ..... | 6 | +| 2 References ..... | 6 | +| 2.1 Informative references ..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 7 | +| 3.1 Terms ..... | 7 | +| 3.2 Symbols ..... | 7 | +| 3.3 Abbreviations ..... | 8 | +| 4 SMO Context based on current O-RAN specifications ..... | 8 | +| 4.1 Existing services in O-RAN specifications ..... | 8 | +| 4.2 Other services and external terminations ..... | 10 | +| 5 SMO Services: Scenarios and Use Cases ..... | 11 | +| 5.1 RAN NF OAM related SMOSs ..... | 11 | +| 5.1.1 RAN NF Performance Assurance Management SMO Service (NFPM) ..... | 12 | +| 5.1.2 RAN NF Fault Supervision Management SMO Service (NFFM) ..... | 12 | +| 5.1.3 RAN NF Provisioning Management SMO Service (NFCM) ..... | 12 | +| 5.2 Non-RT RIC related SMOSs ..... | 13 | +| 5.2.1 rApps Management SMOS ..... | 13 | +| 5.3 Topology and Inventory related SMOS ..... | 13 | +| 5.3.1 Topology Exposure and Inventory Management SMOS ..... | 13 | +| 5.4 Service Management and Exposure (SME) SMOS ..... | 14 | +| 5.4.1 Overview ..... | 14 | +| 5.4.2 Use Case: SME reuse for SMO ..... | 14 | +| 5.5 Data Management and Exposure (DME) SMOS ..... | 14 | +| 5.5.1 Overview ..... | 14 | +| 5.5.2 Use Case: DME data types handling for SMO ..... | 14 | +| 5.6 O-Cloud resources management and orchestration related SMOSs ..... | 15 | +| 5.6.1 Network Function Orchestration SMOS (NFO) ..... | 15 | +| 5.6.1.1 Overview ..... | 15 | +| 5.6.2 Federated O-Cloud Orchestration and Management SMOS (FOCOM) ..... | 15 | +| 5.6.2.1 Overview ..... | 15 | +| 5.6.2.2 Use Case: O-Cloud management ..... | 15 | +| 5.7 RAN Network Slice Subnet Management SMOS ..... | 16 | +| 5.7.1 Overview ..... | 16 | +| 5.7.2 Use Case: RAN Network Slice Subnet Management ..... | 16 | +| 5.8 RAN Analytics SMOS ..... | 16 | +| 5.8.1 Overview ..... | 16 | +| 5.8.2 Use Case: RAN traffic analytics sharing with 5GC ..... | 17 | +| 5.9 Service Orchestration SMOS ..... | 17 | +| 5.9.1 Overview ..... | 17 | +| 5.9.2 Use Cases for SO SMOS ..... | 18 | +| 5.10 Service Assurance SMOS ..... | 18 | +| 5.10.1 Overview ..... | 18 | +| 5.10.2 Use Case: ..... | 18 | +| 5.11 Software package onboarding SMOS ..... | 19 | + +| | | | +|--------|---------------------------------------------------------------------------------------------------|----| +| 5.11.1 | Overview ..... | 19 | +| 5.12 | AI/ML Workflow SMOSs..... | 19 | +| 5.12.1 | Overview ..... | 19 | +| 5.12.2 | Use Cases..... | 19 | +| 5.13 | Policy Management and Information (PMI) SMOS ..... | 20 | +| 5.13.1 | Overview ..... | 20 | +| 6 | SMO Functions (SMOFs)..... | 21 | +| 6.1 | Possible Solutions for SMOF deployment..... | 21 | +| 6.1.1 | Overview ..... | 21 | +| 6.1.2 | Solution Approach 1: RAN NF OAM SMO Function (RNOAMF) ..... | 21 | +| 6.1.3 | Solution Approach 2: O-Cloud Resources Management and Orchestration SMO Function (ORMO SMOF)..... | 21 | +| 6.1.4 | Solution Approach x: Non-RT RIC SMO Function (nonRTR SMOF) ..... | 21 | +| 6.1.5 | Solution Approach: RAN analytics SMOS in non-RT RIC (NONRTR SMOF)..... | 22 | +| 6.1.6 | Solution Approach: Service Orchestration and Assurance (SOSA) SMOF..... | 23 | +| 6.1.7 | Solution Approach: Separate SO SMOF and SA SMOF ..... | 24 | +| 6.2 | Recommended Architectural Approach..... | 25 | +| 6.2.1 | Overview ..... | 25 | +| 7 | Conclusion ..... | 27 | +| | Annex: Change History ..... | 47 | + +# --- List of figures + +| | | +|----------------------------------------------------------------------------------------------------|----| +| Figure 4.1-1: Non-RT RIC Reference Architecture as per [i.3]..... | 9 | +| Figure 4.1-2: Categories of SMOSs based on documented O-RAN SMO capabilities..... | 9 | +| Figure 4.1-3 : SBA representation of the documented SMO services in July 2022 specifications ..... | 10 | +| Figure 6.1.5-1: RAN Analytics SMOS in the non-RT RIC, in the SMO architecture..... | 23 | +| Figure 6.2.1-1: SMO capabilities represented as SMOSs in the SMO SBA approach..... | 26 | + +# --- List of tables + +| | | +|-----------------------------------------------------------------------|----| +| Table 7-1: Proposed SMOSs and status of work as of October 2023 ..... | 28 | +|-----------------------------------------------------------------------|----| + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +--- + +# Modal verbs terminology + +In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and "cannot" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"must" and "must not" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Introduction + +The O-RAN Service Management and Orchestration (SMO) covers a wide and diverse range of functions; some are specific to the Radio Access Network (RAN) domain while others are relatively more generic functions which integrate across RAN and other domains such as cloud infrastructure and other networks. The SMO includes the Non-RT RIC, and the O-RAN architecture assigns some specific SMO functions as being anchored inside or outside the Non-RT RIC Framework. There are several SMO functions which can be implemented in different ways by different solution providers. This study analyses how to improve O-RAN SMO architecture to support multi-vendor interoperability and it looks at integration of existing standardized functions with new ones defined in O-RAN. + +There is a strong need for O-RAN to identify and decouple SMO Functions (SMOFs) and the related SMO Services (SMOSs) within the SMO for the following reasons: + +- (a) Operators could have legacy systems covering some SMO Functions which need to integrate with other newer SMO Functions. +- (b) Operators could integrate SMO into their existing network, management, orchestration, and RAN control elements by consuming the services provided by SMO. +- (c) Deployment and scaling considerations could indicate a natural separation of functions into SMO Functions such that there is an M:N mapping of the number of different SMO Functions in an operator's network. +- (d) SMO Functions could be supplied by different vendors. +- (e) RAN-specific and generic functions are likely to have different development cycles. +- (f) The operational requirements, deployment, scaling, life cycle management of different components could be different. + +There is an opportunity for O-RAN to provide more specification detail within the SMO in terms of realization of components and their connectivity. This would meet the needs of the industry which are listed above. The benefits of such specification work include: + +- (a) Decoupling and better definition of the different SMO Functions fosters ecosystem partnerships and enables optimized solution choices for operators. +- (b) Decoupling and better definition of the different SMO Functions facilitates better standardized interactions between the RAN and non-RAN (e.g., transport and core) systems. +- (c) Specifying each of the SMO Functions and the corresponding SMO Services could help to better understand the security requirements of these SMO Functions rather than looking at the SMO as a black box from one vendor. + +The objective of this Technical Report is to propose solutions for a decoupled SMO architecture to enable standardized interworking between SMO Functions from different vendors, so as to better serve the needs of mobile network operators. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The objective of this Technical Report is to study the high-level requirements for the decoupled SMO architecture, and propose solutions for the decoupled SMO architecture. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. +- [i.2] O-RAN.WG1.O-RAN-Architecture-Description, “O-RAN Working Group 1; O-RAN Architecture Description”. +- [i.3] O-RAN.WG2.Non-RT-RIC-ARCH-TS, “O-RAN Working Group 2; Non-RT RIC Architecture Technical Specification”. +- [i.4] O-RAN-WG4. MP.0-v09.00: “O-RAN Working Group 4 (Open Fronthaul Interfaces WG) Management Plane Specification”. +- [i.5] O-RAN-WG10.OAM-Architecture-v07.00: “O-RAN Operations and Maintenance Architecture v07.00”. +- [i.6] O-RAN-WG10.O1-Interface-v07.00: “O-RAN Operations and Maintenance Interface Specification v07.00”. +- [i.7] O-RAN.WG1.Use-Cases-Analysis-Report-R003-v10.00: “O-RAN Working Group 1 Use Cases Analysis Report”. +- [i.8] O-RAN.WG2.R1GAP, “O-RAN Working Group 2; R1 interface: General Aspects and Principles”. +- [i.9] O-RAN.WG6.O2-GA&P-v02.00, “O2 Interface General Aspects and Principles” +- [i.10] O-RAN.WG1.Use-Cases-Detailed-Specification: “O-RAN Working Group 1 Use Cases Detailed Specification”. +- [i.11] O-RAN.WG1.Slicing-Architecture-v08.00: “O-RAN Working Group 1 Slicing Architecture”. + +- [i.12] O-RAN.WG6.ORCH-USE-CASES-v04.00: “O-RAN.WG6.ORCH-USE-CASES-v04.00 Technical Specification ” +- [i.13] O- RAN.WG2.R1 UCR, O-RAN Working Group 2 (Non-RT RIC and A1 interface WG) R1 Use Cases and Requirements +- [i.14] 3GPP TS 28.104 “3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Management and orchestration; Management Data Analytics (MDA)” +- [i.15] 3GPP TS 23.288 “3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Architecture enhancements for 5G System (5GS) to support network data analytics services” +- [i.16] 3GPP TS 28.531 “3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Management and orchestration; Provisioning” +- [i.17] 3GPP TS 28.532 “3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Management and orchestration; Generic management services +- [i.18] 3GPP TS 28.541 “Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3” +- [i.19] 3GPP TR 28.801 “Telecommunication management; Study on management and orchestration of network slicing for next generation network” +- [i.20] 3GPP TS 28.530 “3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Management and orchestration; Concepts, use cases and requirements” +- [i.21] O-RAN.WG10.TAI-v01.00; “Topology Exposure and Inventory Management Services; Use Cases and Requirement Specification”. + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [i.1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [i.1]. + +For the purposes of the present document, the following terms apply: + +**CNF:** Function in the network designed using cloud-native principles and orchestrated using cloud-native technologies. + +**Non-RT RIC:** O-RAN Non-Real-Time RAN Intelligent Controller. Please refer to [i.3] for more information. + +**Non-RT RIC Framework:** Please refer to [i.3] for more information. + +**SMO:** A Service Management and Orchestration system as described in [i.2] Section 4.3.1 + +**SMO Service (SMOS):** Standardized cohesive set of management, orchestration and automation capabilities offered by an SMO Function. + +**SMO Functions (SMOFs):** Internal SMO entities which provide one or more SMO Services. +Note: An SMO Function exposes standardized interfaces which enable interoperability between SMO Functions. + +**VNF:** see definition in ETSI GR NFV 003. + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +| | | +|-----|-------------------------------------------------------------------------------------------------------------------------| +| NRB | Transmission bandwidth configuration, expressed in units of resource blocks (for E-UTRA)
| +|-----|-------------------------------------------------------------------------------------------------------------------------| + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [i.1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [i.1]. + +| | | +|------|--------------------------------------| +| CNF | Cloud-native Network Function | +| DME | Data Management and Exposure | +| DMS | Deployment Management Service | +| IMS | Infrastructure Management Service | +| IV | Inventory management | +| PNF | Physical Network Function | +| SA | Service Assurance | +| SME | Service Management and Exposure | +| SMO | Service Management and Orchestration | +| SMOF | SMO Function | +| SMOS | SMO Service | +| SO | Service Orchestration | +| SOSA | Service Orchestration and Assurance | +| TE | Topology Exposure | +| VNF | Virtualised Network Function | + +# --- 4 SMO Context based on current O-RAN specifications + +## 4.1 Existing services in O-RAN specifications + +According to definition, a SMOS is a set of capabilities offered by an SMOF. This clause summarizes SMO-related capabilities and services identified and/or defined in July 2022 O-RAN specifications. + +The architecture of the SMO is captured in different O-RAN specifications, each focusing on different areas of SMO. The non-RT RIC architecture described in [i.3] specifies the reference architecture of the Non-RT RIC as part of the SMO framework, as shown in the figure 6-1 of [i.3] and reiterated below for visibility: + +![Figure 4.1-1: Non-RT RIC Reference Architecture as per [i.3]. This diagram illustrates the Non-RT RIC Reference Architecture. It shows the SMO Framework interacting with External E1 Sources, External AI/ML services, and External Oversight. The SMO Framework includes Other SMO framework functions, O2 related functions, O1 related functions, and O2 termination. The Non-RT RIC includes rApp, R1 termination, R1 service management and exposure functions, Other Non-RT RIC framework functions, AI/ML workflow functions, Data Management and exposure functions, A1 related functions, and A1 termination. The Non-RT RIC framework is shown as a dashed box. The architecture is anchored inside or outside the Non-RT RIC framework. The diagram also shows the O-Cloud, Near-RT RIC, and E2 Nodes. The legend indicates Functions anchored inside the Non-RT RIC framework (blue), Functions anchored outside the Non-RT RIC framework (orange), Non-anchored functions (dashed), O-RAN defined interface (solid line with dots), External interface (dashed line with dots), and Production and consumption of R1 services (dashed line with dots).](54cfd211a572ecfbfa807035fac1f52c_img.jpg) + +Figure 4.1-1: Non-RT RIC Reference Architecture as per [i.3]. This diagram illustrates the Non-RT RIC Reference Architecture. It shows the SMO Framework interacting with External E1 Sources, External AI/ML services, and External Oversight. The SMO Framework includes Other SMO framework functions, O2 related functions, O1 related functions, and O2 termination. The Non-RT RIC includes rApp, R1 termination, R1 service management and exposure functions, Other Non-RT RIC framework functions, AI/ML workflow functions, Data Management and exposure functions, A1 related functions, and A1 termination. The Non-RT RIC framework is shown as a dashed box. The architecture is anchored inside or outside the Non-RT RIC framework. The diagram also shows the O-Cloud, Near-RT RIC, and E2 Nodes. The legend indicates Functions anchored inside the Non-RT RIC framework (blue), Functions anchored outside the Non-RT RIC framework (orange), Non-anchored functions (dashed), O-RAN defined interface (solid line with dots), External interface (dashed line with dots), and Production and consumption of R1 services (dashed line with dots). + +**Figure 4.1-1: Non-RT RIC Reference Architecture as per [i.3]** + +Based on the figure 4.1-1 above, the SMO contains a series of functionalities. Several R1 services are identified, and are being described in [i.8] chapter 3, for exposure via R1 interface: + +- Service management and exposure services (SME) +- Data management and exposure services (DME) +- A1-related Services +- O1-related Services +- O2-related Services +- AI/ML Workflow Services. + +In addition, the O2 services are described in [i.9], and there are two main services identified over O2 interface, O2DMS and O2IMS, which have the corresponding functionality coordinated via NFO and FOCOM respectively. The O1 services are identified in [i.6] and are represented as SMOSs in section 5 of this document. + +The SMO capabilities have been specified in O-RAN WG specifications in various manners (either as interface services, or subsets of functions). Taking into consideration the main SMO capabilities in the July 2022 O-RAN specifications, there are three categories of SMO capabilities that can be derived and further be used as a base for the SMOS definitions: + +- Non-RT RIC related SMOSs +- O-Cloud management and orchestration related SMOSs +- RAN NF OAM related SMOSs. + +The three SMOS categories are depicted in figure 4.1-2 below. + +![Figure 4.1-2: Categories of SMOSs based on documented O-RAN SMO capabilities. This diagram shows the SMO (Service Management and Orchestration) framework. It contains three main categories of SMOSs (Service Management and Orchestration Services): Non-RT RIC Services, O-Cloud Resources Management and Orchestration Services, and RAN NF OAM Services. The SMO is represented by a large rounded rectangle, and the three categories are shown as dashed boxes within it.](23b7bd98084ae29576a3d548ca49573d_img.jpg) + +Figure 4.1-2: Categories of SMOSs based on documented O-RAN SMO capabilities. This diagram shows the SMO (Service Management and Orchestration) framework. It contains three main categories of SMOSs (Service Management and Orchestration Services): Non-RT RIC Services, O-Cloud Resources Management and Orchestration Services, and RAN NF OAM Services. The SMO is represented by a large rounded rectangle, and the three categories are shown as dashed boxes within it. + +**Figure 4.1-2: Categories of SMOSs based on documented O-RAN SMO capabilities** + +Figure 4.1-3 provides an SBA representation of the identified SMO capabilities (e.g., R1 Services and the R1 service interfaces, O2dms and O2ims services, RAN NF OAM services) based on July 2022 O-RAN specifications. + +For consistency with the SBA approach of this document and the definition of a SMOS, these SMO capabilities are represented as candidates to be used as a basis for identifying SMOSs. Identification of SMOFs which produce the SMOSs are addressed in section 6 of this document. + +![Figure 4.1-3: SBA representation of the documented SMO services in July 2022 specifications. The diagram shows a Service Based Interface (SBI) architecture for the Service Management and Exposure (SME) and Data Management and Exposure (DME) services. The SMO (Service Management and Exposure) is represented as a collection of SMO capabilities (candidate SMOS) that provide services to the R1 Services (R1 Service Based Interface). The SMO capabilities are categorized into: Network Function Orchestrator (NFO), Federated O-Cloud Orchestrator and Management (FOCOM), RAN NF OAM Services (RAN NF FM, RAN NF CM, RAN NF PM), AI/ML workflow, and A1 related services. The SMO capabilities are connected to the R1 Services via the SBI. The SMO capabilities are also connected to the O-Cloud (via O2 interface), O-RU (via Open FH M-plane and O1 interface), and Near-RT RIC (via A1 interface). The diagram includes a legend for SMO capabilities, O-RAN defined interfaces, and external interfaces.](a056fd415f9b8c8fe6a711772f224313_img.jpg) + +Figure 4.1-3: SBA representation of the documented SMO services in July 2022 specifications. The diagram shows a Service Based Interface (SBI) architecture for the Service Management and Exposure (SME) and Data Management and Exposure (DME) services. The SMO (Service Management and Exposure) is represented as a collection of SMO capabilities (candidate SMOS) that provide services to the R1 Services (R1 Service Based Interface). The SMO capabilities are categorized into: Network Function Orchestrator (NFO), Federated O-Cloud Orchestrator and Management (FOCOM), RAN NF OAM Services (RAN NF FM, RAN NF CM, RAN NF PM), AI/ML workflow, and A1 related services. The SMO capabilities are connected to the R1 Services via the SBI. The SMO capabilities are also connected to the O-Cloud (via O2 interface), O-RU (via Open FH M-plane and O1 interface), and Near-RT RIC (via A1 interface). The diagram includes a legend for SMO capabilities, O-RAN defined interfaces, and external interfaces. + +**Figure 4.1-3 : SBA representation of the documented SMO services in July 2022 specifications** + +The following sections of the present document will address: + +- 1) The naming of the interfaces can be done as part of the normative stage 2 work based on the analysis and recommendations from section 5,6 and 7. +- 2) Though the figure does not explicitly illustrate, an objective for this study, is to determine a common set of SMOSs' across the SMOFs. When this is the case, these are indicated throughout the next sections, by explicit statements about use of several common SMOSs by the different SMOS producers. + +## 4.2 Other services and external terminations + +Requirements for “External Terminations” described in Figure 4.1-1 are not yet addressed in the July 2022 O-RAN specifications. + +An example of external exposure of SMO Services using SME and DME principles, can be represented in an SBA approach as depicted in figure 4.2-1. + +![Figure 4.2-1: SMO external terminations diagram. The diagram shows two main functional blocks, 'Data Management and Exposure (DME)' and 'Service Management and Exposure (SME)', enclosed in a dashed blue box. Above each block is a large blue double-headed arrow representing an external interface. A legend below the diagram defines the symbols: a double-headed arrow for 'External interface', a T-shaped symbol for 'Consumption of services', an inverted T-shaped symbol for 'Production of services', and a rounded rectangle for 'SMO capabilities'. The DME and SME blocks are shown with both consumption and production interfaces.](4e1909f0476f5843a5e3c32b56ad681b_img.jpg) + +Figure 4.2-1: SMO external terminations diagram. The diagram shows two main functional blocks, 'Data Management and Exposure (DME)' and 'Service Management and Exposure (SME)', enclosed in a dashed blue box. Above each block is a large blue double-headed arrow representing an external interface. A legend below the diagram defines the symbols: a double-headed arrow for 'External interface', a T-shaped symbol for 'Consumption of services', an inverted T-shaped symbol for 'Production of services', and a rounded rectangle for 'SMO capabilities'. The DME and SME blocks are shown with both consumption and production interfaces. + +**Figure 4.2-1: SMO external terminations** + +In Figure 4.1-1, the “Other SMO framework functions” and the “Other Non-RT RIC framework functions” have been used as placeholder for aspects not yet defined in the O-RAN specifications from their services perspective. + +Examples of essential functionality in SMO to be addressed in this study, include: + +- Service Orchestration, including aspects of coordinating the orchestration of a chain of RAN NFs, their connectivity, and the assurance of such RAN NF chaining. +- Topology and Inventory management +- Network Slice Subnet management (see [i.11] for use cases and functional description). + +# 5 SMO Services: Scenarios and Use Cases + +## 5.1 RAN NF OAM related SMOs + +The SMO manages O-RAN Network Functions (NFs) using the O-RAN OAM Architecture [WG10.OAM]. As listed in the O-RAN OAM architecture section 2.2.1.1 [WG10.OAM], these O-RAN Network functions (NFs) include the following radio side entities: Near-RT RIC, O-CU-CP, O-CU-UP, O-DU, and O-RU Managed Functions. As shown in “Figure 4.1-1: High Level Architecture of O-RAN” of the O-RAN Architecture Specification [WG1.ARCH], the O-RAN Network Functions communicate with the SMO via O1, A1 and Open Fronthaul M-plane interfaces. In the current O-RAN architecture, the NF-related Management Services (MnS) over the O1 interface and Open Fronthaul M-Plane interface are consumed by the SMO. As defined in 3GPP, MnS composed of 3 parts: Component A, B and C. In order to meet the demand for the consumption of MnS, e.g., collect data of MnS component B and C for intelligent analysis, and consume MnS component A for operating O-RAN NFs, we envision that the SMO needs to have the capability to consume the NF-related MnS and provide related services to different SMO Functions (SMOFs) as a set of RAN NF OAM SMO Services. + +Examples of Management Services supported by O-RAN are listed in section 3.3.1.1 of [WG10.OAM] and section 2 of [WG10.O1]. As an example, in order to fulfil the UE service SLA assurance, Non-RT RIC will consume RAN NF OAM SMO Services to collect OAM data for analysis. Non-RT RIC will host policies and applications which can be used to generate actions which are executed through the SMO external interfaces, e.g., A1 and O1 interfaces. In order to fulfil the optimization goal or end user service SLA assurance in use cases such as Context-Based Dynamic HO Management for V2X, Flight Path Based Dynamic UAV Radio Resource Allocation, Radio Resource Allocation for UAV Application Scenario, QoE Optimization, RAN Slice SLA assurance [WG1.UC-DS], it is a pre-requisite that measurement data, RAN PM data, QoE data need to be collected and provided to Non-RT RIC for further analyzing. + +Different intelligent use cases require different types of RAN management data, including performance data, alarm data, and NF NRM-related data. The SMO needs to have the capability to collect this data and provide it efficiently to SMOFs. The triggering of data collection and the consumption of data can be accomplished with SMO RAN NF OAM SMO Services. In alignment with [WG10.O1][WG4.M-Plane], the SMO offers the following three RAN NF OAM SMO Services, and details of each are described in sections 5.1.1, 5.1.2, and 5.1.3 respectively: + +- RAN NF Performance Assurance Management SMO Service (NFPM): Provide RAN NF performance data collection obtained by consuming PM MnS via O1 interface and Open Fronthaul M-Plane interface. +- RAN NF Fault Supervision Management SMO Services (NFFM): Provide RAN NF fault data (e.g., Alarm) collection obtained by consuming FM MnS via O1 interface and Open Fronthaul M-Plane interface. +- RAN NF Provisioning Management SMO Services (NFCM): Provide RAN NF NRM-related data collection and modification services and obtained by consuming MnS via O1 interface and Open Fronthaul M-Plane interfaces. + +The interfaces exposing the RAN NF OAM SMO Services for consumption by other SMOFs provide flexible mechanisms to allow their service consumers to narrow down the target of their requests (e.g., to specific areas, NFs, cells, etc.). + +### 5.1.1 RAN NF Performance Assurance Management SMO Service (NFPM) + +#### 5.1.1.1 Use Case: Performance Management for O-RAN NF instances + +##### 5.1.1.1.1 High Level Description + +To monitor real-time performance data and enable consumers within SMO to detect issues in advance, it is needed for SMOFs to consume performance measurement jobs of an NF. The NFPM SMOS provides a mechanism for the NFPM SMOS consumers to create and terminate the PM job as well as querying the related PM information. + +The collected performance data is reported to the NFPM SMOS consumer in the format of files or data streaming in accordance with the requested method. + +### 5.1.2 RAN NF Fault Supervision Management SMO Service (NFFM) + +#### 5.1.2.1 Use Case: Enable Fault Supervision Services for NF instances + +##### 5.1.2.1.1. High Level Description + +For the purposes of Fault Supervision, it is needed for SMOFs to get alarm list alarm list, clear or acknowledge one or multiple alarms of an NF. The service for a one-time query is also required. + +### 5.1.3 RAN NF Provisioning Management SMO Service (NFCM) + +#### 5.1.3.1 Use Case: Enable Configuration Management for O-RAN NF instances + +##### 5.1.3.1.1 High Level Description + +For the purposes of Configuration Management, it is needed for SMOFs to manage configuration (creation, deletion, modification, or query) of an NF. + +The NFCM SMOS provides a mechanism for the NFCM SMOS consumers to request a change to the network over the appropriate interface, such as the O1 and Open Fronthaul M-plane interfaces. NFCM manages changes to the network in terms of conflict and frequency of change. It is also responsible for translating a provisioning request into the proper format for the configuration schema of the targeted NF(s) and then uses the appropriate protocol, such as the O1 and Open Fronthaul M-Plane, to affect the change in the element. The NFCM SMOS also provides a mechanism to receive and facilitate processing of all CM notifications from the NF(s), including notification of configuration changes which were not directly requested by the NFCM SMOS mechanism. + +## 5.2 Non-RT RIC related SMOSs + +### 5.2.1 rApps Management SMOS + +#### 5.2.1.1 Overview + +The non-RT RIC provides management services to support rApps. The rApp management service handles management aspects specific to rApps such as: + +- rApp Configuration Management (CM): enables management of the rApp configuration settings, +- rApp Performance Management (PM): offers support for performance reporting on an rApp performance, or of the rApp communication with the non-RT RIC framework (rApp usage of R1 interface), +- rApp Fault Management (FM): provides the fault reporting capabilities to rApps, so they can consume it to report faults that are related to the rApp, or to the rApp communication with the non-RT RIC framework (rApp usage of R1 interface), +- rApp Logging Information: enables rApps to convey their logging information to the non-RT RIC framework, +- rApp lifecycle management services, that expose services that allow to trigger rApp software lifecycle management. + +## 5.3 Topology and Inventory related SMOS + +### 5.3.1 Topology Exposure and Inventory Management SMOS + +For the SMO to perform efficient operation and maintenance of O-RAN and to enable a global view of the O-RAN resources, it is important to maintain an inventory of O-RAN resources. Visualization and optimization of the network rely upon knowing and maintaining the relationship between O-RAN resources (i.e. network view). Topology Exposure (TE) and Inventory Management (IV) services provide an up-to-date information of O-RAN resources and their relationships. + +NOTE: O-RAN resources include resources used to realize the O-RAN Radio Network including network functions, subnet slice, cloud resources, radio resources, and transport resources. + +O-RAN.WG1.Use-Cases-Detailed-Specification [i.10] specifies use cases related to optimization of radio resources which can benefit from Topology Exposure Service to provide network view of the radio resources. O-RAN.WG1.Slicing-Architecture [i.11] specifies use cases related to RAN network slice that deal with network slice resources which can benefit from Topology Exposure Service to provide network view of the available RAN, cloud and transport resources. Topology Exposure Service can assist the Network Subnet Slice Management Service to identify the available or impacted O-DU, O-CU and O-RU instances. O-RAN.WG6.ORCH-USE-CASES [i.12] specifies use cases related to discovery/allocation/deallocation of various types of cloud resources to O-Cloud instance and xNF LCM. These use cases will benefit from Topology Exposure Service to provide them the network view of cloud resources. + +O-RAN WG10 Architecture Specification [i.5] has a service provisioning use case that refers to population of information about VNFs and PNFs in the inventory. There is a functional requirement for SMO (REQ-M&O-FUN4) to support the inventory of newly activated PNFs and VNFs. Inventory Management Service will satisfy this requirement. + +The Topology Exposure and Inventory Management SMOSs are expected to offer CRUD capabilities and notifications pertaining to change events on O-RAN resource objects. + +NOTE: The Topology Exposure and Inventory Management Service(s) definition as part of stage 2 work will be based on outcome from the WG10 Topology Exposure and Inventory Management WI. + +## 5.4 Service Management and Exposure (SME) SMOS + +### 5.4.1 Overview + +The SME service is introduced in the [i.8] section 3.1. While the SME was initially targeted for management and exposure of rApp services in the [i.8], its services are applicable to any entities within the SMO that fulfil the roles of Service Producer and/or Service Consumer. + +In a decomposed service-based SMO architecture, the SME can be leveraged as a generic SMOS, handling service management and exposure for any SMOSs within SMO. The SME SMOS provides a set of common SMO capabilities that are needed for all SMO Services. + +Several of the SME services are applicable to any SMOSs: + +- SMOS registration, +- SMOS discovery, +- Authentication and authorization to access a SMOS, +- Communication support between SMOS Service Producers and SMOS Service Consumers (SMOS Communication), +- Bootstrap of new SMOSs (optional), +- Heartbeat of SMOSs (optional). + +### 5.4.2 Use Case: SME reuse for SMO + +The use cases described for the SME in [i.13] section 4 can be applicable to any SMOSs beyond rApps, where a SMOF can act in a role of one, or both, the Service Producer and Service Consumer. + +## 5.5 Data Management and Exposure (DME) SMOS + +### 5.5.1 Overview + +The DME services and their producers, the logical DME functions, are introduced in the Non-RT RIC Architecture specification [i.3], providing capabilities that allow DME Data Consumers to discover data types, consume collected data, and further allow DME Data Producers to register data types and to produce data for collection. The DME services can handle any registered data types and expose them for discovery and consumption to DME Data Consumers. In the [i.8] section 3.2, both the DME Data Producer and DME Data Consumer are restricted to refer only to rApps, because the scope of [i.8] is the R1 interface between rApps and the SMO/Non-RT RIC framework. + +In a decomposed service-based SMO architecture, the DME SMOS can be leveraged as an enabler handling any SMOS data types, therefore any SMOF can be a DME Data Producer and/or a DME Data Consumer. + +The definition of DME services as exposed via the R1 interface currently specifies how rApps interact with the DME services in the roles of DME Data Producer and DME Data Consumer. Within the SMO wider scope these two roles are now associated with any of the SMOFs which can benefit from using DME SMOS to register, produce, discover and consume data. + +### 5.5.2 Use Case: DME data types handling for SMO + +There are several use cases described for the DME in [i.13] section 5. These use cases are also applicable to any SMOFs in a role of one, or both, of DME Data Producer and DME Data Consumer. + +## 5.6 O-Cloud resources management and orchestration related SMOSs + +### 5.6.1 Network Function Orchestration SMOS (NFO) + +#### 5.6.1.1 Overview + +The NFO SMOS is responsible for the orchestration of the O-Cloud resources, used for the deployment of the NF Deployments that constitute the cloudified NFs, either using the ETSI NFV O2DMS profile or the Kubernetes® O2DMS profile. That includes the initial deployment of the software and any subsequent lifecycle management actions necessary on the respective NF Deployments instances, such as healing, updates, scaling, software upgrades, termination, etc. The functionality of the NFO is introduced in [i.9]. + +O-RAN NFs can also be deployed as PNFs, in which case O-Cloud resources are not used (rather the appliance model applies). + +The deployment constructs PNF, CNF and VNF do not impose any specific cardinality with the O-RAN NF. It is expected that one O-RAN NF has a [0..n] cardinality with any of the PNF, CNF or VNF. + +#### 5.6.1.2 Use Case: NF Deployments + +Several orchestration use cases are described in [i.12]. + +### 5.6.2 Federated O-Cloud Orchestration and Management SMOS (FOCOM) + +#### 5.6.2.1 Overview + +The Federated O-Cloud Orchestration and Management is introduced in [i.9]. Its capabilities cover management of O-Cloud resources and provide two main categories of services: + +- the O-Cloud Infrastructure Resource Management, +- the management of the abstracted resources and DMSes (e.g., the management of the software deployed to provide virtualization technologies such as containers or VMs). + +The capabilities of FOCOM SMOS include: + +- maintaining the O-Cloud Infrastructure data in the SMO inventory, +- monitoring the infrastructure, +- provisioning the infrastructure, +- infrastructure software management, +- infrastructure lifecycle management. + +#### 5.6.2.2 Use Case: O-Cloud management + +The O-Cloud basic use cases providing several scenarios related to different aspects of the O-Cloud lifecycle management and for O-Cloud software management are defined in [i.12]. + +## 5.7 RAN Network Slice Subnet Management SMOS + +### 5.7.1 Overview + +The RAN Network Slice Subnet management (NSSM) exposes the RAN subnetwork slice provisioning related capabilities as specified in section 6.2 “Management services for network slice subnet provisioning” in TS 28.531 [i.16] with the operations defined in TS 28.532 [i.17] and Network slice subnet NRM related information models defined in clause 6.3 of TS 28.541 [i.18]. + +The NSSI (Network Subnet Slice Instance defined in TS 28.530 [i.20]) provisioning operations include: + +- create an NSSI; activate an NSSI; deactivate an NSSI; modify an NSSI; terminate an NSSI; get NSSI data, allocate NSSI to an NSI, deallocate NSSI from NSI. + +The NSSI provisioning data reporting adds support for subscription/notification mechanisms for some of the provisioning operations: notifications of creation, notification of deletion, notification of attribute changes. + +A RAN NSSM SMOS producer relies on other SMOSs in order to provide the NSSI provisioning functionality, e.g.: + +- SME SMOS, for the registration of the RAN subnet slice management capabilities offered and for discovery of other SMOSs that it needs to consume, +- SO SMOS, that performs the orchestration and management coordination required for the NSSI’s components: + - the component RAN NFs that best match the requirements received from the RAN NSSM SMOS producer, + - coordination with NFO Producer to request LCM actions as needed for the O-RAN NF Deployments, and coordination with FOCOM to request O-Cloud management actions, + - where applicable, to obtain the suitable TNs for the RAN NFs inter and intra-connections, that fulfil the requirements received, +- SA SMOS, that performs the assurance of the overall RAN service represented by the NSSI components, based on the service requirements and characteristics provided. + +### 5.7.2 Use Case: RAN Network Slice Subnet Management + +Use cases for RAN Network Slice Subnet Management are described in [i.19] and in clause 3 of [i.11] + +## 5.8 RAN Analytics SMOS + +### 5.8.1 Overview + +RAN analytics SMOS consumes data and services produced by the SMO then it processes and analyses them using its internal logic and algorithms to produce RAN analytics output. The RAN analytics output includes RAN traffic predictions or statistics (such as UE mobility predictions) and recommendations related to RAN management. + +RAN analytics are useful for both internal SMO consumption as well as external consumers (e.g., 5GC such as NWDAF, as specified in 3GPP TS 28.104 [i.14] and 3GPP TS 23.288 [i.15]). + +The 3GPP MDA as specified in 3GPP TS 28.104 uses input data that relates to both RAN traffic and RAN management data and has defined several data types related to RAN analytics. These data types are also useful in O-RAN context and can be extended with additional analytics data types that address O-RAN use cases and requirements such as the ones listed in section 5.2.3.1 of this document. + +NOTE: the RAN traffic analytics exposed in a real-time manner via the Y1 interface are not analysed in this document. Whether SMO consumes Y1 or not is not addressed in the present document. + +RAN Analytics SMOS registers with DME the data types of the RAN analytics, and/or RAN management analytics that they produce. This allows the analytics data discovery by interested consumers via DME. Such analytics data types can be the existing standardized 3GPP MDA data types specified in 3GPP TS 28.104 [i.14], or they can be new analytics data types defined in O-RAN. + +The SMO exposes RAN analytics to SMOS consumers (e.g., internal in SMO, or 5GC NF such as NWDAF, or other SMOS external consumers) via SME, with a service interface based on the MDA interface specified in 3GPP TS 28.104 [i.14]. Asynchronous data delivery to external SMOS consumers via DME is achieved using the DME push data service described in R1 GAP [i.9] section 5.2.6.3 “Push data service”. + +External SMOS consumers that want to consume the RAN analytics SMOS offered by the SMO, need to be able to: + +- Consume the discovery service of the SME to discover the RAN analytics SMOS in the SMO, using the interface exposed by SME for that purpose. +- Consume services produced by DME SMOS to perform one, or more of: data discovery for the RAN Analytics SMOS data types, subscriptions to RAN analytics data types of interest, the Pull data and/or Push data from DME. +- Consume the RAN Analytics SMOS, by performing the needed service invocations requests following the MDA interface specification from 3GPP TS 28.104[i.14]. + +### 5.8.2 Use Case: RAN traffic analytics sharing with 5GC + +The use cases are described in section 3.23 “Use case 23: Sharing Non-RT RIC Data with the Core” of the WG1 Use Cases Analysis report [i.7] and in section 3.23 “Use case 23: Sharing Non-RT RIC Data with the Core” of the WG1 Use Cases Detailed Specification [i.10]. In order to fulfil the use case, it is important to make RAN analytics SMOS capabilities discoverable by 5GC (e.g., by NWDAF). + +The use cases for the 3GPP MDA data are specified in 3GPP TS 28.104 [i.14]. + +## 5.9 Service Orchestration SMOS + +### 5.9.1 Overview + +As part of a zero-touch automation goal for the management of RAN, the SMO is expected to be capable to coordinate autonomously the execution of its services. The Service Orchestration (SO) SMOS plays an important role in the overall SMO automation. + +The SO SMOS provides the overseeing capabilities to automate orchestration of one or more O-RAN NFs and associated management (e.g., CM day 0..n) that allow to correlate, sequence and coordinate individual actions performed using other SMOSs, with the end goal of fulfilling requirements that impact one or several NFs, O-Cloud and the Transport Networks (TN) used to interconnect O-RAN NFs (inter-NF) and NF Deployments (intra-NF) when they are deployed over different sites. The SO SMOS offers automation capabilities based on standardized models for automation flows, that enable proper correlation, sequencing, and timing of the needed actions, such as: + +- Coordination of the orchestration for one or more RAN NFs (also including multiple NF Deployments), including taking the homing decision considering both the application-level requirements (e.g., assurance levels expected the proximity to radio equipment, etc.) and non-functional requirements (e.g., infrastructure capabilities needed). +- Coordination of management and orchestration for RAN service requests (which could include multiple RAN NFs) that must meet the RAN E2E service requirements and characteristics (e.g., overall availability, RAN E2E SLA, areas for coverage, number of subscribers supported, etc). +- Decomposition of RAN service requests (multiple O-RAN NFs) into the appropriate O-RAN NF constituents, deriving their dimensioning, characteristics and configuration required, to fulfil the received RAN service request. +- Based on data obtained on TNs, selection of a suitable TN that fulfils the requirements of the RAN E2E service requirements and characteristics (e.g., RAN E2E service latency, throughput). + +- Capability to process service requests received from upper layer service orchestrators and to perform any required actions to fulfil such request in the RAN management domain. + +### 5.9.2 Use Cases for SO SMOS + +#### 5.9.2.1 Use case: SO dynamic resource orchestration + +##### 5.9.2.1.1 High Level Description + +This use case shows how the Service Orchestrator dynamically adjusts resource provisioning as traffic demand changes, as expected in the use case described in [i.10]. The SO SMOS consumer in this use case is an SO SMOS Consumer (e.g., rApp) which uses AI/ML to forecast traffic demand and then, based on the forecast, translates it into a request to the SO SMOS Producer. An example of a request is to specify an optimized topology information for a certain traffic volume over a period of time by shutting down several O-RAN NFs for Network Energy Saving, moving the remaining O-RAN NFs to appropriate O-cloud nodes, and rearranging connections between O-RAN NFs. + +Based on the received SO SMOS request, the SO determines that in order to fulfil it, it will have to take a series of actions, such as: change the current configuration of several O-RAN NFs by making a request to the RAN NF OAM SMOF (NFCM SMOS Producer) and make several NF Deployment LCM requests to the ORMO SMOF (NFO SMOS). Additionally, it involves requesting Network configuration changes to external Transport Network (TN) Manager. + +## 5.10 Service Assurance SMOS + +### 5.10.1 Overview + +The SA SMOS responsibility is to sustain the required assurance levels set for the RAN E2E services, or for the O-RAN NFs instances that are managed and orchestrated by the SMO. For this purpose, it collects, consolidates, and detects when the RAN E2E service or NF level assurance falls below the required levels, so that subsequent remedial actions can be taken. + +The SA SMOS offers a closed loop automation approach, where: + +- It monitors/observes the data that is relevant to assessing the current RAN E2E service and NF assurance levels (including the application and O-Cloud resources used by the software). +- It analyses the observed data in order to determine if the RAN E2E service and NF assurance levels are met or not. +- In case the RAN E2E service and NF assurance levels are not met, decisions are taken on a course of remedial actions. +- The identified actions (e.g., configuration changes, scaling, changes of connectivity, etc.) are executed in collaboration with other SMO services (SO, RAN NF OAM, etc.). +- The closed loop automation is continuously applied, as the data that is relevant to show the result of the remedial actions is again monitored and analysed. Any needed decisions are taken and resulting actions continue to be executed as part of the closed loop automation for assurance purposes, until the monitoring data collected shows an outcome that meets the required assurance levels. + +### 5.10.2 Use Case: + +#### 5.10.2.1 High Level description: + +## 5.11 Software package onboarding SMOS + +### 5.11.1 Overview + +The software package onboarding SMOS provides support for onboarding software packages such as O-RAN NFs, O-RAN rApps, and O-RAN xApps. The software package onboarding SMOS exposes capabilities for: + +- software packages ingestion into SMO, +- security verification of the software packages (e.g., integrity protection such as vendor signatures, etc), +- validation of software packages to ensure that the format and contents can be understood by the SMO, +- extraction of the software package artifacts into appropriate catalogues and storage of software images into the appropriate repos. + +## 5.12 AI/ML Workflow SMOSs + +### 5.12.1 Overview + +AI/ML workflow SMO Services enable the management of AI/ML related capability in support of O-RAN SMO operations. + +The following AI/ML workflow services are currently identified in e.g., [i.3]: + +- AI/ML training services: allow an AI/ML training service consumer to request training of an AI/ML model by specifying the training requirements (e.g., required data, model, validation criteria, etc). +- AI/ML model management and exposure services: + - AI/ML model registration/deregistration: allows an AI/ML SMOS producer to register, update the registration of, and deregister the AI/ML model that it provides. An AI/ML SMOS producer needs to be authorised to register, update the registration of, or deregister the AI/ML model it provides. + - AI/ML model discovery: allows an AI/ML SMOS consumer to discover registered AI/ML model(s) based on its selection criteria if it is provided. The AI/ML SMOS consumer needs to be authorised to discover registered AI/ML models. + - AI/ML model change subscription: allows an AI/ML SMOS consumer to subscribe and receive notifications of changes of a registered AI/ML model. + - AI/ML model storage: allows an AI/ML SMOS consumer to request the storage of an AI/ML model it registered and the AI/ML model associated information. + - AI/ML model training capability registration/deregistration (optional service): allows an AI/ML SMOS producer to register/update/deregister its capability of training an AI/ML model. + - AI/ML model retrieval: allows an AI/ML SMOS consumer to request model location details of a specific version of a registered AI/ML model. + - AI/ML model performance monitoring services: allow an authorised AI/ML SMOS consumer to request monitoring the performance of a deployed AI/ML model. + +### 5.12.2 Use Cases + +Use cases involving AI/ML workflow SMO Services are described in [i.10]. Examples are: + +- QoE optimization +- Massive MIMO Beamforming Optimization + +- RAN Slice SLA Assurance +- Energy Saving + +## 5.13 Policy Management and Information (PMI) SMOS + +### 5.13.1 Overview + +A policy refers to a set of rules, guidelines, or conditions that govern the behaviour and actions of O-RAN resources and services. Policies are used to automate various aspects of network resources and services; they ensure that the network services and their resources operate in accordance with predefined rules and objectives. Policies can typically be expressed in a structured format that defines the scope, objectives, and conditional statements or constraints. + +For the SMO to ensure that O-RAN resources such as O-Cloud, O-RAN nodes are allocated and managed consistently and efficiently, it is important to manage these O-RAN resources through policies. One of the most important goals of Policy Management and Information (PMI) is to support policy-driven decision processes controlled by the SMO within the O-RAN system. + +There are three different roles related to policies: + +- 1) Policy Administration Point (PAP), responsible for the provisioning of policies (create, update, delete, get), (As defined in NIST Glossary here [https://csrc.nist.gov/glossary/term/policy\\_administration\\_point](https://csrc.nist.gov/glossary/term/policy_administration_point)) +- 2) Policy Decision Point (PDP), responsible to determine where in a decision process a certain policy can be applied, (As defined in NIST Glossary here ) +- 3) Policy Enforcement Point (PEP), responsible for the executing the actions derived from the policies. (As defined in NIST Glossary here [https://csrc.nist.gov/glossary/term/policy\\_enforcement\\_point](https://csrc.nist.gov/glossary/term/policy_enforcement_point)) + +Depending on the use case, a SMOF can act in one or more of these roles. + +The Policy Management and Information (PMI) SMOS allows service consumers to specify and provision policies for SMOFs such as the producers of NFO, FOCOM, RANOAM etc., and A1 policies for the Near-RT RIC etc., hence representing the PAP role only. Policy Management and Information (PMI) SMOS decouples policy management from the underlying entities that apply and execute them, i.e., which play a PDP and/or PEP role. [The](#) PDP/PEP role can be played by SMOFs or by entities outside SMO, such as in case of A1 policies by the Near-RT RIC. + +The Policy Management and Information (PMI) SMOS main capabilities are listed below (non-exhaustive list): + +- Policy type registration and deregistration: A PMI SMOS consumer can request to create and register the policy types it supports with Policy Management and Information (PMI), also allows to delete, and deregister policy types. Some examples of policy types can be resource management, LCM such as healing and scaling, monitoring etc. +- Discover and Query Policy types: A PMI SMOS consumer can request to discover, and query supported policy types. +- Create, Query/Read, Update, Delete policies: PMI SMOS consumers can request to create, query/read, update and delete policies for any SMOF (as well as A1 policies for the near-RT RIC) that is supporting the related policy types as known to the PMI. +- Discover Policies: A PMI SMOS consumer can request to discover policies maintained by PMI SMOS producer. +- Policy Status: PMI SMOS consumer request to query/read status of policies, such as enforced, running, not enforced etc. obtained by PMI SMOS producer from the PDPs and PEPs. +- Subscribe/Notify: A PMI SMOS consumer can subscribe for notifications of events such as policy changes related to policies and policy types. + +# 6 SMO Functions (SMOFs) + +## 6.1 Possible Solutions for SMOF deployment + +### 6.1.1 Overview + +This clause describes examples of deployment scenarios for SMO Functions (SMOF). + +### 6.1.2 Solution Approach 1: RAN NF OAM SMO Function (RNOAMF) + +This solution addresses the SMOs described in section 5.1 “RAN NF OAM related SMOs”. + +This solution approach considers the deployment scenario where there is a RAN NF OAM SMO Function (RNOAMF) which provides the functionality for operations, administration, maintenance, and management of the radio side of the O-RAN architecture as envisioned in the O-RAN OAM architecture [WG10.OAM]. The RAN NF OAM SMO Services (NFPM, NFFM, NFCM) listed in section 5.1.1, 5.1.2, 5.1.3 are produced by the RAN NF OAM SMOF. These SMO Services represent an essential aspect of the SMO and will typically be consumed by the Non-RT RIC and possibly by other SMO Functions. In addition, they could also be consumed by entities within the RAN NF OAM SMOF, for example for coordination or correlation. + +### 6.1.3 Solution Approach 2: O-Cloud Resources Management and Orchestration SMO Function (ORMO SMOF) + +This solution addresses the SMOs described in section 5.x “O-Cloud resources management and orchestration related SMOs” and places the NFO SMOs and the FOCOM SMOs together into one SMO Function, the ORMO SMOF. This approach leverages on the synergies between the two SMOs and aims to facilitate a level of coordination between them. This is useful specifically in orchestration scenarios, where an automated sequence of NFO and FOCOM actions needs to be orchestrated in order to fulfil the successful deployment of a CNF or a VNF into the right infrastructure resources, respecting the infrastructure requirements from the deployment descriptors of the CNF or VNF. + +#### 6.1.3.1 SMOF interactions within SMO + +The ORMO SMOF can register its service capabilities using the services of the SME SMOs described in section 5.y. It enables their discoverability by other SMOFs, as well as their external exposure via SME. The ORMO SMOF can discover other SMOs by consuming SME services. + +The ORMO SMOF uses the Topology and Inventory SMOs to obtain data about inventoried resources managed by other SMOFs (e.g., PNFs for connectivity, cell topology, etc). The ORMO SMOF uses the Topology and Inventory SMOs to update availability and characteristics data about O-Cloud infrastructure resources and NF deployments managed by ORMO SMOs. + +The ORMO SMOF consumes the DME SMOs described in section 5.5, to: + +- register the data types it produces, using the services of the DME SMOs described in section 5.5. This enables the discoverability of ORMO data types by other SMOFs, as well as their external exposure via SME and DME. +- discover data types produced by other SMOs, for subsequent consumption as part of the ORMO SMOF internal logic. + +### 6.1.4 Solution Approach x: Non-RT RIC SMO Function (nonRTR SMOF) + +#### 6.1.4.1 Overview + +This solution addresses the SMOs described in section 5.2 “Non-RT RIC related SMOs” and places them under one SMOF. + +The nonRTR SMOF offers two main types of capabilities: + +- nonRTR SMOF framework capabilities, and +- rApps capabilities, which complement the existing SMOSs and provide enhancements to SMO overall capabilities. + +The nonRTRF framework services allow exposure of SMOSs to rApps via the R1 interface. + +#### 6.1.4.2 SMOF interactions within SMO + +The nonRTR SMOF interacts with other services in SMO, as follows: + +- It registers its service capabilities using the services of the SME SMOS described in section 5.4. This enables the discoverability of the nonRTR SMOF services (including rApps) by other SMOFs, as well as their external exposure via SME. +- It discovers via the SME SMOS other available SMOSs available in the SMO, +- It registers the data types produced by the nonRTR (including rApps) using the services offered by the DME SMOS described in section 5.5; +- It discovers via the DME SMOS other data types available for consumption in the SMO, +- It consumes Topology Exposure and Inventory Management SMOS described in section 5.3: + - to obtain topology data about the RAN network resources, O-Cloud resources, transport resources and any relationship(s) between them. + - to obtain also any network inventory asset data related to RAN, O-Cloud and transport that does not imply a relationship with other assets (e.g., versions of the software available, etc). + - to request updates of topology and inventory data, for the assets that the nonRTR SMOF (including rApps) is authorized and/or responsible to update. +- It consumes any other SMOSs that is authorized to consume from the SMO, such as the RAN NF OAM SMOSs described in section 5.1 and O-Cloud Resources Management and Orchestration SMOSs described in section 5.6. + +### 6.1.5 Solution Approach: RAN analytics SMOS in non-RT RIC (NONRTR SMOF) + +This solution addresses the RAN Analytics SMOS described in section 5.x “RAN Analytics SMOS” and places it under the nonRTR SMOF, as a SMOS produced by rApps. + +The rationale behind this solution proposal is that given the wide variety of RAN analytics that can be offered, as well as the fact that support for new RAN analytics (traffic and/or RAN MDA) need to be flexibly added on the fly, the RAN analytics SMOS is produced by the non-RT RIC via rApps. + +A depiction of the RAN analytics SMOS in non-RT RIC is shown in the figure below. + +![Figure 6.1.5-1: RAN Analytics SMOS in the non-RT RIC, in the SMO architecture. The diagram shows an External SMOS Consumer (5GC/NWDAF, etc.) interacting with the SMO. The SMO contains Service Management and Exposure (SME) and Data Management and Exposure (DME) components. These interact with Other SMO Services (SMOS) and RAN Analytics SMOS. The RAN Analytics SMOS is connected to R1 Services, which are connected to Other SMO Services (SMOS) in the Non-RT RIC. The diagram also shows SMOS Communication and 3GPP MDA MnS (3GPP TS 28.104) and DME Asynch / Push data interfaces.](1b573bfb618887a43d7fba1490155965_img.jpg) + +Figure 6.1.5-1: RAN Analytics SMOS in the non-RT RIC, in the SMO architecture. The diagram shows an External SMOS Consumer (5GC/NWDAF, etc.) interacting with the SMO. The SMO contains Service Management and Exposure (SME) and Data Management and Exposure (DME) components. These interact with Other SMO Services (SMOS) and RAN Analytics SMOS. The RAN Analytics SMOS is connected to R1 Services, which are connected to Other SMO Services (SMOS) in the Non-RT RIC. The diagram also shows SMOS Communication and 3GPP MDA MnS (3GPP TS 28.104) and DME Asynch / Push data interfaces. + +Figure 6.1.5-1: RAN Analytics SMOS in the non-RT RIC, in the SMO architecture + +### 6.1.6 Solution Approach: Service Orchestration and Assurance (SOSA) SMOF + +This solution addresses the SMOSs described in clause 5.9 “Service Orchestration SMOS” and 5.10 “Service Assurance SMOS” and places the SO SMOS and the SA SMOS together into one SMO Function, the SOSA SMOF. The SO and SA SMOSs have functional correlation and interdependencies, such as orchestration decisions being taken using assurance input and assurance being achieved by leveraging orchestration and automation capabilities. This approach is considering the synergies between the two SMOSs and aims to facilitate a closer coordination between them. + +#### 6.1.6.1 SMOF interactions within SMO + +The SOSA SMOF consumes other SMOSs to realize and deliver the SO and SA SMOSs, as follows: + +- It consumes the SME SMOS described in section 5.4, to: + - register its service capabilities using the services of the SME SMOS. This enables their discoverability by other SMOFs, as well as their external exposure via SME. + - discover other SMOSs by consuming SME services. + - As applicable, perform service invocation for any SMOSs, by requesting authorization from SME. +- It consumes the DME SMOS described in section 5.5, to: + - register the data types it produces, using the services of the DME SMOS described in section 5.5. This enables the SOSA data types’ discoverability by other SMOFs, as well as their external exposure via SME and DME. + - discover data types produced by other SMOSs, for subsequent consumption as part of the SOSA SMOF internal logic. +- It consumes the Topology and Inventory SMOSs described in section 5.3, to: + - query the TE &IV SMOS to obtain data about inventoried resources managed by other SMOFs (e.g., PNFs for connectivity, cell topology, existing NF instances, etc.) that is needed as input in order to realize its SMOSs. + - populate data using the TE &IV SMOS when it created new RAN services, or to update information related to the successful outcome of the orchestration decisions that it has taken. + +- It consumes the RAN NF OAM related SMOSs described in section 5.1, to: + - make OAM management requests related to the O-RAN NFs (e.g., CM, PM, FM). +- It consumes the NFO SMOS described in section 5.6.1, to: + - make lifecycle management requests for the NF Deployments and request day 0 configurations. +- It consumes the FOCOM SMOS described in section 5.6.2, to: + - request management of O-Cloud infrastructure resources, in preparation for deployments of the O-RAN NFs (e.g., obtain information about certain O-Cloud resources, change infrastructure resources allocation to a Node Cluster, create new Node Clusters). + - obtain PM, FM data about the O-Cloud resources which have running NF Deployment instances. + - obtain O-Cloud inventory information about O-Cloud resources. +- It consumes SMOSs offered by rApps via the non-RT RIC, that complement and enhance the functionality offered to SOSA SMOSs, such as: + - RAN Analytics SMOS as described 5.8, to use as input to its orchestration and/or assurance decisions. + - rApps services that provide resolution for the functional composition of requested RAN services and/or O-RAN NFs. + - other rApps that provide services and data that can be consumed by the SOSA SMOF. + +#### 6.1.6.2 SMOF interactions with services outside SMO + +The SOSA SMOF interacts with Transport Network (TN) domain Managers, which are external to the SMO, to: + +- request a connectivity that meets certain characteristics. +- query the TN topology to discover existing TNs and their data that are relevant and of interest to the SOSA SMOF. +- retrieve FCAPS data that is relevant for SOSA SMOF to understand the SLA fulfilment level for the TNs is using (e.g., enable monitoring FM, PM for TN by the SMO). + +The SOSA SMOF interacts with upper layer service orchestrators to perform any required actions to fulfil such request in the RAN management domain. + +### 6.1.7 Solution Approach: Separate SO SMOF and SA SMOF + +This solution addresses the SMOSs described in section 5.9 “Service Orchestration SMOS” and section 5.10 “Service Assurance SMOS” and places the SO SMOS in the SO SMOF and the SA SMOS in the SA SMOF or in the non-RT RIC SMOF. + +NOTE: When SA SMOS placed in rApp via Non-RT RIC SMOF, R1 Interface shall include SA related services + +#### 6.1.7.1 SO SMOF + +##### 6.1.7.1.1 SO SMOF interactions within SMO + +The SO SMOF interactions with the SMOS Producers of: SME, DME, TE & IV, RAN NF OAM SMOSs, NFO and FOCOM, are same as described in section 6.1.5.1 of this present document. + +#### 6.1.7.2 SA SMOF + +##### 6.1.7.2.1 SA SMOF interactions within SMO + +The SA SMOF interactions with the SMOS Producers of: SME, DME, TE &IV, RAN NF OAM SMOSs, NFO and FOCOM, are same as described in section 6.1.5.1 of this present document. + +In addition, the SA SMOF consumes other SMOSs to realize and deliver the SA SMOS as follows: + +- It consumes services of SO SMOS that enable the functionality offered by SA SMOSs, such as: + - To request SO SMOS services for orchestration related actions (e.g., configuration changes, scaling, changes of connectivity, policies etc.) . + - To request coordination of management and orchestration for RAN service requests that include multiple RAN NFs that must meet the RAN E2E service requirements and characteristics (e.g., overall availability, RAN E2E SLA, areas for coverage, number of subscribers supported, etc). + - To interact with SO SMOS within joint closed control loops automation, that involve both SO and SA SMOSs. +- It consumes services of rApps via Non-RT RIC that may assist the functionality offered by SA SMOSs, such as: + - RAN Analytics SMOS as described 5.8, to use as input to its assurance activities. + - Non-RT RIC services realized via rApps that provide resolution for the functional composition of requested RAN services and/or O-RAN NFs. + - Non-RT RIC services realized via rApps that provide other supporting services (e.g., AI/ML-enabled services). + +## 6.2 Recommended Architectural Approach + +### 6.2.1 Overview + +The SMO capabilities identified as SMOSs in clause 5 of this document are represented in a service-based architecture in the figure 6.2.1-1 below. All the SMO Service producers represented in figure 6.2.1-1 can also be SMOS consumers. + +**O-RAN-WG1.Decoupled-SMO-Architecture-TR-R004-v03.00** + +Image: O-RAN Alliance Logo + +![Figure 6.2.1-1: SMO capabilities represented as SMOSs in the SMO SBA approach](a3c0786df44a43752a87efbcea85b67a_img.jpg) + +The diagram illustrates the SMO Service Based Architecture (SBA) approach. Inside the main 'SMO' boundary, there is an 'SMOS Communication' bus connecting various SMO Services (SMOSs). These include: 'Software Package Onboarding', 'Service & Subnet Slice Orchestration', 'Service & Subnet Slice Assurance', 'Topology & Inventory (TE&IV)', 'AI/ML Workflow', 'Data Management and Exposure (DME)', 'Service Management and Exposure (SME)', 'rApp SMOSs', 'rApp Management', 'Network Function Orchestrator (NFO)', 'Federated O-Cloud Orchestration and Management (FOCOM)', 'RAN NF OAM', 'RAN Analytics', 'Policy Mgmt and Information (PMI)', 'A1 EI Management', and 'A1 Policy Management'. External consumers of SMOSs connect from the top. Below the SMO boundary, interfaces like O2, Open FH M-plane, O1, and A1 connect to external entities such as 'O-Cloud', 'O-RU', 'Near-RT RIC', and 'Other O1 Nodes'. A legend at the bottom defines SMO interfaces, external interfaces, consumption/production of services, and SMOS producers. + +Figure 6.2.1-1: SMO capabilities represented as SMOSs in the SMO SBA approach + +**Figure 6.2.1-1: SMO capabilities represented as SMOSs in the SMO SBA approach** + +Following the Service Based Architecture principles, only SMO Services are specified to ensure interoperability. + +A SMOF implementation can produce and/or consume any combinations of one or more SMOSs, provided that the SMOF complies with the O-RAN specifications of the interfaces exposing the SMOSs. + +Except for the Non-RT RIC SMOF which is defined to provide support for rApps and for A1 related SMOSs, the definition of SMOFs is in general not in scope of the O-RAN specifications, as the interoperable functional behaviour of SMOFs is only specified via the SMOS Producer/Consumer roles. For example, a particular Non-RT RIC implementation may be a SMOF producing SME SMOS, DME SMOS, AI/ML workflow SMOS, and the SMOSs anchored in the Non-RT RIC, where both the SME SMOS and DME SMOS are produced and consumed only internally to the SMO. + +In order to ensure consistency with the already specified functions related to the SMO interfaces within the O-RAN network domain (i.e., O1, O-FH M-plane, O2, and A1), the following SMOSs identified in section 5 of the present document are recommended to be specified: + +- RAN NF OAM SMO Services, including + - o RAN NF Performance Assurance Management (NFPM) + - o RAN NF Fault Supervision Management (NFFM) + - o RAN NF Provisioning Management (NFCM) + - o Others, e.g., Tracing, Logging, etc. +- Network Functions Orchestration (NFO) SMOS +- Federated O-Cloud Orchestration and Management (FOCOM) SMOS +- Service Management and Exposure (SME) SMOS [i.8] +- Data Management and Exposure (DME) SMOS [i.8] +- Topology Exposure and Inventory Management (TE&IV) SMOS [i.21] +- RAN Analytics SMOS + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. + +26 + +- Service & Subnet Slice Orchestration SMOS +- Service & Subnet Slice Assurance SMOS +- AI/ML workflow (AIMLWF) SMOS [i.8] +- rApp Management SMOS [i3] +- A1 Enrichment Information Management SMOS [i.8] +- A1 Policy Management SMOS [i.8] +- Software package onboarding SMOS +- RAN Network Slice Subnet Management, +- Policy Management and Information (PMI). + +SME SMOS supports the exposure of other SMOSs, as described in sect. 4.2, to both internal and external SMOS consumers. + +DME SMOS supports the exposure of data produced by SMOS Producers, to both internal and external SMOS consumers. + +Examples of external SMOS consumers are 5GC/NWDAF, E2E Service Management Domain. + +NOTE: the details of the SMO Services that are already defined, or under definition, by O-RAN are described in the referenced specifications. + +As an implementation option, SMOS (e.g. RAN Analytics, Service Assurance, etc. - see sect. 6.1) can be provided by SMOF such as the Non-RT RIC SMOF (which can be realized with rApps), or as SMOFs outside Non-RT RIC. Whether the two options will have different requirements on the definition of the SMOS is FFS in the normative phase. + +# 7 Conclusion + +The analysis conducted in the “Decoupled SMO Architecture” work item demonstrated the feasibility of a Service Based architecture for SMO to be standardized according to the principles described in Sect. 6.2. + +SMO Services (SMOS) candidate for the standardization were identified to support the proposed use cases. A description of SMOS and related use case examples is provided in Sect. 5. + +For the subsequent normative phase, the following items are identified: + +- update the O-RAN Architecture Description specification to reflect the SBA SMO architecture and principles, +- identify the SMOS interfaces to start with in the first phase, and identify the WGs to support ATG, according to their scope and terms of reference, +- define Stage 2 and Stage 3 workplan. + +The summary of the SMOS services and the status of related service interface work as of October 2023 is captured in table 7-1 below. + +| Standardized SMOS Interface | Status | Reference section | +|-----------------------------|---------------------------------------------------|-------------------| +| RAN NF OAM: PM | Initial service description exists in [i.8] [i.3] | 5.1.1 | +| RAN NF OAM: FM | Initial service description exists in [i.8] [i.3] | 5.1.2 | +| RAN NF OAM: CM | Initial service description exists in [i.8] [i.3] | 5.1.3 | + +| | | | +|---------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------| +| Non-RT RIC related SMOs:
rApp management | Initial service description will be defined in [i.8] (logging available). | 5.2.1 | +| A1 Policy Management SMOS | Initial service description exists in [i.8] | | +| A1 Enrichment Information Management SMOS | Initial service description exists in [i.8] | | +| TE & IV | Initial Information Model exists in [i.21] | 5.3 | +| SME | Initial service description exists in [i.8] [i.3] | 5.4 | +| DME | Initial service description exists in [i.8] [i.3] | 5.5 | +| NFO | New interface to be specified | 5.6.1 | +| FOCOM | New interface to be specified | 5.6.2 | +| RAN analytics | Initial interface description exists in [i.14]. To be further expanded for O-RAN data types. | 5.8 | +| RAN Network Slice Subnet Management | Interface and operations defined in TS 28.531 [i.16]TS 28.532 [i.17]and Network slice subnet NRM related information models defined in clause 6.3 of TS 28.541 [i.18] | 5.7 | +| Service Orchestration | New interface to be specified | 5.9 | +| Service Assurance | New interface to be specified | 5.10 | +| SW package onboarding | New interface to be specified | 5.11 | +| AI/ML workflows | Initial service description will be defined in [i.8] | 5.12 | +| Policy Management and Information (PMI) | New interface to be specified | 5.13 | + +**Table 7-1: Proposed SMOs and status of work as of October 2023** + +Table 3: + +# --- Annex A (informative): Example Diagrams of Scenarios and Use Cases for SMOS A.1 Use Case NFFM SMOS: Enable Fault Supervision Services + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | NFFM SMOS provides fault supervision services to the NFFM SMOS consumers. | | +| Actors and Roles | [1]. RNOAMF (producer of NFFM SMOS): RAN OAM SMOF that produces RAN OAM SMOS.
[2]. NFFM SMOS Consumer: SMOF that consumes NFFM SMOS.
[3]. O-RAN NF: O-CU-CP, O-CU-UP, O-DU, O-RU or near-RT RIC.
[4]. SME: Service Management Exposure SMOS. | | +| Assumptions | None | | +| Pre-conditions | [1]. The RNOAMF (NFFM SMOS) works normally and can provide NFFM SMOS to other SMOF(s).
[2]. RNOAMF (NFFM SMOS) has registered its data types with DMESs SMOF.
[3]. Secure network connectivity is already available between O-RAN NF(s).
[4]. O-RAN NF(s) works normally. | | +| Begins when | NFFM SMOS Consumer decides to get active alarm list, clear, or acknowledge one or multiple alarms on an NF instance. | | +| Step 1 | RNOAMF registers NFFM SMOS capabilities by using SME SMOS: GetAlarmList, AcknowledgeAlarms, ClearAlarms; | | +| Step 2 | NFFM SMOS Consumer discovers the NFFM services via SME SMOS. | | +| Step 3 | NFFM SMOS Consumer requests service | | +| Step 4-7 | Service Request is for GetAlarmList | | +| Step 4 | RNOAMF gets alarm list from the O-RAN NF over O1 interface. | | +| Step 5 | O-RAN NF returns Alarm List over O1 interface. | | +| Step 6 | RNOAMF gets alarm list from the O-RAN NF over Open Fronthaul M-plane interface. | | +| Step 7 | O-RAN NF returns Alarm List over Open Fronthaul M-Plane interface. | | +| Step 8-15 | Service request is for AcknowledgeAlarms | | +| Step 8 | If the O-RAN NF supports manual alarm Acknowledge, RNOAMF sets the acknowledged state for specified alarms in the O-RAN NF over O1 interface. | | +| Step 9 | O-RAN NF returns success or fail of Modification request | | +| Step 10 | O-RAN NF sends FM notification. | | +| Step 11 | If the O-RAN NF supports manual alarm Acknowledge, RNOAMF sets the acknowledged state for specified alarms in the O-RAN NF over Open Fronthaul M-Plane interface. | | +| Step 12 | O-RAN NF returns success or fail of Modification request | | +| Step 13 | O-RAN NF sends FM notification. | | +| Step 14 | RNOAMF sends AlarmAcknowledged notification if a subscription for it exists | | +| Step 15 | RNOAMF sends modification notification if a subscription for it exists | | +| Step 16-23 | Service request is for ClearAlarms | | +| Step 16 | RNOAMF sets the cleared state for specified alarms in the O-RAN NF over O1 interface. | | +| Step 17 | O-RAN NF returns success or fail of Modification request | | +| Step 18 | O-RAN NF sends FM notification. | | +| Step 19 | RNOAMF sets the cleared state for specified alarms in the O-RAN NF over Open Fronthaul M-Plane interface. | | +| Step 20 | O-RAN NF returns success or fail of Modification request | | +| Step 21 | O-RAN NF sends FM notification. | | +| Step 22 | RNOAMF sends AlarmCleared notification if a subscription for it exists | | +| Step 23 | RNOAMF sends modification notification if a subscription for it exists | | +| Step 24 | RNOAMF returns success or fail of service request | | +| Ends when | SMOS Consumer receives the success or fail of the request. | | +| Exceptions | Not applicable | | +| Post Conditions | Not applicable | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|----------------|---------------------------|-------------------------| +| Traceability | TODO: FFS | | + +``` + +@startuml +Autonumber +skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +Box "Service Management & Orchestration\nFramework\n(Subscriber)" #gold + Participant "SMOS Consumer" as SMOF + Participant "RNOAMF (NFFM SMOS)" as SMOS + Participant "Service Management Exposure" as SMES +end box + +Box "O-RAN" #lightpink + Participant "O-RAN\nNF" as NF +end box + +ref over SMOS, SMES : Register Fault Supervision Services:\n\tGetAlarmList/Acknowledge Alarms/Clear Alarms +ref over SMOF, SMES : Discover Fault Supervision Services +Autonumber 3 +SMOF -> SMOS : ServiceRequest +Alt Request is for AlarmList + Opt If retrieving Alarmlist from O-RAN NF is needed + Alt Use O1 + SMOS -> NF : <<01>> Request to get AlarmList + NF --> SMOS : <<01>> AlarmList + Else Use M-Plane + SMOS -> NF : <> Request to get AlarmList + NF --> SMOS : <> AlarmList + end + end +Else if Request is for AcknowledgeAlarms + Opt Manual Alarm Acknowledge is supported + Alt Use O1 + SMOS -> NF : <<01>> Modification + NF --> SMOS : <<01>> Success/Fail + NF ->> SMOS : FM Notification + Else Use M-Plane + SMOS -> NF : <> Modification + NF --> SMOS : <> Success/Fail + NF ->> SMOS : FM Notification + End + End +End + Opt If a qualifying Alarm notification subscription exists + SMOS ->> SMOF : AlarmAcknowledgeNotification End + Opt If a qualifying CM notification subscription exists + SMOS ->> SMOF : ModificationNotification + End end +Else Request is for ClearAlarms + Alt Use O1 + SMOS -> NF : <<01>> Modification + NF --> SMOS : <<01>> Success/Fail + NF ->> SMOS : FM Notification + else Use M-Plane + SMOS -> NF : <> Modification + NF --> SMOS : <> Success/Fail + NF ->> SMOS : FM Notification + end + Opt If a qualifying Alarm notification subscription exists + SMOS ->> SMOF : AlarmClearNotification + End + +``` + +``` + + Opt If a qualifying CM notification subscription exists + SMOS -->> SMOF : ModificationNotification + EndEnd +SMOS --> SMOF : RequestResponse + +@enduml +@startuml +Autonumber +skinparam sequenceArrowThickness 2 +skinparam participantPadding 5 +skinparam BoxPadding 10 + +Box "Service Management & Orchestration\nFramework\n(Subscriber)" #gold + Participant "Other SMOF (Consumer)" as SMOF + Participant "RNOAMF (NFFM SMOS)" as SMOS + Participant "Service Management Exposure" as SMES +end box + +Box "O-RAN" #lightpink + Participant "xNF" as NF +end box + + +SMOS -> SMES : Register Fault Supervision +Services:\n\tGetAlarmList\n\tAcknowledgeAlarms\n\tClearAlarms +SMOF -> SMES : Discover Fault Supervision Services +SMOF -> SMOS : ServiceRequest +Alt Request is for AlarmList + Opt If retrieving Alarmlist from xNF is needed + SMOS -> NF : <<01>> ReadMOI AlarmList + NF --> SMOS : <<01>> AlarmList + end +Else if Request is for AcknowledgeAlarms + Opt Manual Alarm Acknowledge is supported + SMOS -> NF : <<01>> ModifyMOI Alarm + NF --> SMOS : <<01>> ModifyMOI Success/Fail + Opt If a qualifying Alarm notification subscription exists + SMOS -->> SMOF : AlarmAcknowledgeNotification + End + Opt If a qualifying CM notification subscription exists + SMOS -->> SMOF : MOIModificationNotification + End + end +Else Request is for ClearAlarms + SMOS -> NF : <<01>> ModifyMOI Alarm + NF --> SMOS : <<01>> ModifyMOI Success/Fail + Opt If a qualifying Alarm notification subscription exists + SMOS -->> SMOF : AlarmClearNotification + End + Opt If a qualifying CM notification subscription exists + SMOS -->> SMOF : MOIModificationNotification + End +End +SMOS --> SMOF : RequestResponse + +@enduml +@startuml +Autonumber +skinparam sequenceArrowThickness 2 +skinparam participantPadding 5 +skinparam BoxPadding 10 + +Box "Service Management & Orchestration\nFramework\n(Subscriber)" #gold + Participant "Other SMOF (Consumer)" as SMOF + Participant "RNOAMF (NFFM SMOS)" as SMOS + Participant "Service Management Exposure" as SMES +end box + +Box "O-RAN" #lightpink + +``` + +``` + + Participant "xNF" as NF +end box + +SMOS -> SMES : Register Fault Supervision +Services:\n\tGetAlarmList\n\tAcknowledgeAlarms\n\tClearAlarms +SMOF -> SMES : Discover Fault Supervision Services +SMOF -> SMOS : ServiceRequest +Alt Request is for AlarmList + Opt If retrieving Alarmlist from xNF is needed + SMOS -> NF : <<01>> ReadMOI AlarmList + NF --> SMOS : <<01>> AlarmList + end +Else if Request is for AcknowledgeAlarms + Opt Manual Alarm Acknowledge is supported + SMOS -> NF : <<01>> ModifyMOI Alarm + NF --> SMOS : <<01>> ModifyMOI Success/Fail + Opt If a qualifying Alarm notification subscription exists + SMOS --> SMOF : AlarmAcknowledgedNotification + End + Opt If a qualifying CM notification subscription exists + SMOS --> SMOF : MOIModificationNotification + End + end +Else Request is for ClearAlarms + SMOS -> NF : <<01>> ModifyMOI Alarm + NF --> SMOS : <<01>> ModifyMOI Success/Fail + Opt If a qualifying Alarm notification subscription exists + SMOS --> SMOF : AlarmClearNotification + End + Opt If a qualifying CM notification subscription exists + SMOS --> SMOF : MOIModificationNotification + End +End +SMOS --> SMOF : RequestResponse + +@enduml + +``` + +``` + +@startuml +Autonumber +skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +Box "Service Management & Orchestration\nFramework\n(Subscriber)" #gold + Participant "Other SMOF (Consumer)" as SMOF + Participant "RNOAMF (NFFM SMOS)" as SMOS + Participant "Service Management Exposure" as SMES +end box + +Box "O-RAN" #lightpink + Participant "xNF" as NF +end box + +SMOS -> SMES : Register Fault Supervision +Services:\n\tGetAlarmList\n\tAcknowledgeAlarms\n\tClearAlarms +SMOF -> SMES : Discover Fault Supervision Services +SMOF -> SMOS : ServiceRequest +Alt Request is for AlarmList + Opt If retrieving Alarmlist from xNF is needed + SMOS -> NF : <<01>> ReadMOI AlarmList + NF --> SMOS : <<01>> AlarmList + end +Else if Request is for AcknowledgeAlarms + Opt Manual Alarm Acknowledge is supported + SMOS -> NF : <<01>> ModifyMOI Alarm + +``` + +``` + + NF --> SMOS : <<01>> ModifyMOI Success/Fail + Opt If a qualifying Alarm notification subscription exists + SMOS ->> SMOF : AlarmAcknowledgeNotification + End + Opt If a qualifying CM notification subscription exists + SMOS ->> SMOF : MOIModificationNotification + End +end +Else Request is for ClearAlarms + SMOS -> NF : <<01>> ModifyMOI Alarm + NF --> SMOS : <<01>> ModifyMOI Success/Fail + Opt If a qualifying Alarm notification subscription exists + SMOS ->> SMOF : AlarmClearNotification + End + Opt If a qualifying CM notification subscription exists + SMOS ->> SMOF : MOIModificationNotification + End +End +SMOS --> SMOF : RequestResponse +@enduml + +``` + +![](cd840a36a907598ee71b234dff6e5fc4_img.jpg) + +``` + +sequenceDiagram + participant SMOS Consumer + participant RNOAMF (NFFM SMOS) + participant Service Management Exposure + participant O-RAN NF + + Note over RNOAMF (NFFM SMOS), Service Management Exposure: Register Fault Supervision Services: +GetAlarmList/Acknowledge Alarms/Clear Alarms + Note over SMOS Consumer, Service Management Exposure: Discover Fault Supervision Services + SMOS Consumer->>RNOAMF (NFFM SMOS): 3 ServiceRequest + + alt Request is for AlarmList + opt If retrieving Alarmlist from O-RAN NF is needed + alt Use:01 + RNOAMF (NFFM SMOS)->>O-RAN NF: 4 <> Request to get AlarmList + O-RAN NF-->>RNOAMF (NFFM SMOS): 5 <> AlarmList + else Use M-Plane + RNOAMF (NFFM SMOS)->>O-RAN NF: 6 <> Request to get AlarmList + O-RAN NF-->>RNOAMF (NFFM SMOS): 7 <> AlarmList + end + end + else if Request is for AcknowledgeAlarms + opt Manual Alarm Acknowledge is supported + alt Use:01 + RNOAMF (NFFM SMOS)->>O-RAN NF: 8 <> Modification + O-RAN NF-->>RNOAMF (NFFM SMOS): 9 <> Success/Fail + O-RAN NF->>RNOAMF (NFFM SMOS): 10 FM Notification + else Use M-Plane + RNOAMF (NFFM SMOS)->>O-RAN NF: 11 <> Modification + O-RAN NF-->>RNOAMF (NFFM SMOS): 12 <> Success/Fail + O-RAN NF->>RNOAMF (NFFM SMOS): 13 FM Notification + end + end + opt If a qualifying Alarm notification subscription exists + RNOAMF (NFFM SMOS)->>SMOS Consumer: 14 AlarmAcknowledgeNotification + end + opt If a qualifying CM notification subscription exists + RNOAMF (NFFM SMOS)->>SMOS Consumer: 15 ModificationNotification + end + else Request is for ClearAlarms + alt Use:01 + RNOAMF (NFFM SMOS)->>O-RAN NF: 16 <> Modification + O-RAN NF-->>RNOAMF (NFFM SMOS): 17 <> Success/Fail + O-RAN NF->>RNOAMF (NFFM SMOS): 18 FM Notification + else Use M-Plane + RNOAMF (NFFM SMOS)->>O-RAN NF: 19 <> Modification + O-RAN NF-->>RNOAMF (NFFM SMOS): 20 <> Success/Fail + O-RAN NF->>RNOAMF (NFFM SMOS): 21 FM Notification + end + opt If a qualifying Alarm notification subscription exists + RNOAMF (NFFM SMOS)->>SMOS Consumer: 22 AlarmClearNotification + end + opt If a qualifying CM notification subscription exists + RNOAMF (NFFM SMOS)->>SMOS Consumer: 23 ModificationNotification + end + end + + RNOAMF (NFFM SMOS)-->>SMOS Consumer: 24 RequestResponse + +``` + + + +## A.2 Use Case: Performance Management for NF instances + +| Use Case Stage | Evolution / Specification | <>
Related use | +|----------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | NFPM SMOS provides performance measurement services to the NFPM SMOS consumers. | | +| Actors and Roles | [1]. RNOAMF (producer of NFPM SMOS): RAN OAM SMOF that produces RAN OAM SMOS
[2]. NFPM SMOS Consumer: SMOF that consumes NFPM SMOS
[3]. O-RAN NF: O-CU-CP, O-CU-UP, O-DU, O-RU or near-RT RIC
[4]. SME: Service Management Exposure SMOS | | +| Assumptions | None | | +| Pre-conditions | [1]. The RNOAMF (NFPM SMOS) works normally, and can provide NFPM SMOS to other SMOF(s)
[2]. RNOAMF (NFPM SMOS) has registered its data types with DMESs SMOF
[3]. Secure network connectivity is already available between O-RAN NF(s)
[4]. O-RAN NF(s) work normally. | | +| Begins when | NFPM SMOS Consumer decides to create, query, or terminate one or multiple performance measurement job(s) on a NF instance. | | +| Step 1 | RNOAMF registers NFPM SMOS capabilities using the SME SMOS: Creation / Query / Termination of measurement job, target O-RAN NFs (as applicable). | | +| Step 2 | NFPM SMOS Consumer discovers the NFPM services via SME SMOS. | | +| Creation of measurement job | | | +| Step 3 | NFPM SMOS Consumer requests creation of PM job to RNOAMF (producer of NFPM) for a specific O-RAN NF instance. | | +| Step 4-7 | RNOAMF requests collecting performance data to O-RAN NF instance over O1 or Open Fronthaul M-plane. | | +| Step 8 | The result of PM job creation for the O-RAN NF instance is returned by RNOAMF to NFPM SMOS Consumer. | | +| Performance reporting: File format | | | +| Step 9 | If the collected data are file format, notification that file is ready is sent from RNOAMF to NFPM SMOS Consumer. | | +| Step 10 | NFPM SMOS Consumer fetches the file from SMO. | | +| Performance reporting: Data streaming. | | | +| Step 11 | RNOAMF provides the performance data stream to the NFPM SMOS consumer. | | +| Query of measurement job | | | +| Step 12 | NFPM SMOS Consumer queries RNOAMF about the information on the PM job(s). | | +| Step 13 | RNOAMF provides NFPM SMOS Consumer with the requested PM information. | | +| Termination of measurement job | | | +| Step 14 | NFPM SMOS Consumer requests termination of PM job to RNOAMF. | | +| Step 15-18 | RNOAMF requests stopping the PM job to collect performance data from the O-RAN NF instance. | | +| Step 19 | The result of PM job termination is returned by RNOAMF to the NFPM SMOS Consumer. | | +| Ends when | All the steps identified above are successfully completed. | | +| Exceptions | Not applicable | | +| Post Conditions | Not applicable | | +| Traceability | TODO: FFS | | + +``` + +@startuml +Autonumber +skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +Box "Service Management & Orchestration\nFramework\n(Subscriber)" #gold + Participant "SMOS Consumer" as SMOF + Participant "RNOAMF (NFCM SMOS)" as SMOS + Participant "Service Management and Exposure" as SMES +end box + +Box "O-RAN" #lightpink + Participant "O-RAN\nNF" as NF +end box + +SMOS <-> SMES : Register Configuration Management Services:\n\tCreate/Delete +\n\tModify/Query configuration +SMOF <-> SMES : Discover Configuration Management Services +SMOF -> SMOS : ServiceRequest +== Creation == + SMOS -> NF : << O1 >> Creation + NF --> SMOS : << O1 >> Success/Fail +== Deletion == + SMOS -> NF : << O1 >> Deletion + NF --> SMOS : << O1 >> Success/Fail +== Modification == + Alt Use O1 + SMOS -> NF : << O1 >> Modification + NF --> SMOS : << O1 >> Success/Fail + Opt If a qualifying CM notification subscription exists + NF ->> SMOS : CM Notification + End + Else Use OpenFH M-Plane + SMOS -> NF : << OpenFH M-plane >> Modification + NF --> SMOS : << OpenFH M-plane >> Success/Fail + Opt If a qualifying CM notification subscription exists + NF ->> SMOS : CM Notification + End + End + End +== Query == + Opt If retrieving config from O-RAN NF is needed + Alt Use O1 + SMOS -> NF : << O1 >> get + NF --> SMOS : << O1 >> the data + Else Use OpenFH M-Plane + SMOS -> NF : << OpenFH M-plane >> get + NF --> SMOS : << OpenFH M-plane >> the data + End + End + End +==== + Opt If a qualifying CM notification subscription exists + SMOS ->> SMOF : CM Notification + End +SMOS --> SMOF : RequestResponse + +@enduml + +``` + +![Sequence diagram for Performance Management Services in the Service Management & Orchestration Framework (Subscriber).](2823820877c01e4a704fd2ac0b7997ce_img.jpg) + +**Service Management & Orchestration Framework (Subscriber)** + +Participants: SMOS Consumer, RNOAMF (NFPM SMOS), Service Management Exposure, O-RAN NF + +**Initial Setup:** + +- ref** Register Performance Management Services: PM job creation/query/termination target O-RAN NFs (as applicable) +- ref** Discover Performance Management Services + +**Creation of measurement job** + +- 3 Request of PM job creation (SMOS Consumer to RNOAMF) +- 4 <> Request to collect the PM data (RNOAMF to O-RAN NF) +- 5 <> Success/Fail (O-RAN NF to RNOAMF) +- 6 Success/Fail (RNOAMF to SMOS Consumer) + +**Performance reporting** + +**while the measurement job is active** + +- New PM data or its file is available +- alt** + - if the collected data are file format** + - 7 Notification of file ready (RNOAMF to SMOS Consumer) + - 8 Fetch the file (SMOS Consumer to RNOAMF) + - if SMOF retrieves PM data as streaming** + - 9 Send performance data stream (RNOAMF to SMOS Consumer) + +**Query of measurement jobs** + +- 10 Query of measurement job information (SMOS Consumer to RNOAMF) +- 11 Provide the information (RNOAMF to SMOS Consumer) + +**Termination of measurement job** + +- 12 Request of measurement job termination (SMOS Consumer to RNOAMF) +- 13 <> Request to stop collecting the performance data (RNOAMF to O-RAN NF) +- 14 <> Success/Fail (O-RAN NF to RNOAMF) +- 15 Success/Fail (RNOAMF to SMOS Consumer) + +Sequence diagram for Performance Management Services in the Service Management & Orchestration Framework (Subscriber). + +## A.3 Use Case: Enable Configuration Management Services + +| Use Case Stage | Evolution / Specification | <>
Related use | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | NFCM SMOS provides configuration services to the NFCM SMOS consumers. | | +| Actors and Roles | [1]. RNOAMF(producer of NFCM SMOS): RAN OAM SMOF that produces RAN OAM SMOS.
[2]. NFCM SMOS Consumer: SMOF that consumes NFCM SMOS.
[3]. O-RAN NF: O-CU-CP, O-CU-UP, O-DU, O-RU or near-RT RIC.
[4]. SME: Service Management and Exposure SMOS. | | +| Assumptions | None | | +| Pre-conditions | [1]. The RNOAMF(NFCM SMOS) works normally, and can provide NFCM SMOS to other SMOF(s).
[2]. RNOAMF(NFCM SMOS) has registered its data types with DMESs SMOF.
[3]. Secure network connectivity is already available between O-RAN NF(s).
[4]. O-RAN NF(s) works normally. | | +| Begins when | NFCM SMOS Consumer decides to manage configuration(creation, deletion, modification, or query) on an NF instance. | | +| Step 1 | RNOAMF registers NFCM SMOS capabilities using the SME SMOS: Create, Delete, Modify, or Query configuration target O-RAN NF(s)(as applicable). | | +| Step 2 | NFCM SMOS Consumer discovers the NFCM services via SME SMOS. | | +| Step 3 | NFCM SMOS Consumer requests service. | | +| Create configuration | | | +| Step 4 | RNOAMF requests O-RAN NF to create instance over O1 interface. | | +| Step 5 | O-RAN NF returns success or fail of creation request. | | +| Delete configuration | | | +| Step 6 | RNOAMF requests O-RAN NF to delete instance over O1 interface. | | +| Step 7 | O-RAN NF returns success or fail of deletion request. | | +| Modify configuration | | | +| Step 8,11 | RNOAMF requests O-RAN NF to modify instance or data over O1 or Open Fronthaul M-plane interface. | | +| Step 9,12 | O-RAN NF returns success or fail of modification request. | | +| Step10,13 | O-RAN NF sends CM notification. | | +| Query configuration | | | +| Step 14,16 | RNOAMF requests O-RAN NF to query over O1 or Open Fronthaul M-plane interface if retrieving config from the O-RAN NF instance is needed. | | +| Step 15,17 | O-RAN NF returns the data. | | +| Step 18 | RNOAMF sends CM notification if a subscription for it exists. | | +| Step 19 | RNOAMF returns success or fail of service request. | | +| Ends when | NFCM SMOS Consumer receives the success or fail of the request. | | +| Exceptions | Not applicable | | +| Post Conditions | Not applicable | | +| Traceability | TODO: FFS | | + +``` + +@startuml +Autonumber +skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +``` + +``` + +Box "Service Management & Orchestration\nFramework\n(Subscriber)" #gold + Participant " SMOS Consumer" as SMOF + Participant "RNOAMF (NFCM SMOS)" as SMOS + Participant "Service Management and Exposure" as SMES +end box + +Box "O-RAN" #lightpink + Participant "O-RAN\nNF" as NF +end box + +SMOS <-> SMES : Register Configuration Management Services:\n\tCreate/Delete +\n\tModify/Query configuration +SMOF <-> SMES : Discover Configuration Management Services +SMOF -> SMOS : ServiceRequest +== Creation == + SMOS -> NF : << O1 >> Creation + NF --> SMOS : << O1 >> Success/Fail +== Deletion == + SMOS -> NF : << O1 >> Deletion + NF --> SMOS : << O1 >> Success/Fail +== Modification == + Alt Use O1 + SMOS -> NF : << O1 >> Modification + NF --> SMOS : << O1 >> Success/Fail + Opt If a qualifying CM notification subscription exists + NF ->> SMOS : CM Notification + End + Else Use OpenFH M-Plane + SMOS -> NF : << OpenFH M-plane >> Modification + NF --> SMOS : << OpenFH M-plane >> Success/Fail + Opt If a qualifying CM notification subscription exists + NF ->> SMOS : CM Notification + End + End + End +== Query == + Opt If retrieving config from O-RAN NF is needed + Alt Use O1 + SMOS -> NF : << O1 >> get + NF --> SMOS : << O1 >> the data + Else Use OpenFH M-Plane + SMOS -> NF : << OpenFH M-plane >> get + NF --> SMOS : << OpenFH M-plane >> the data + End + End + End +==== + Opt If a qualifying CM notification subscription exists + SMOS ->> SMOF : CM Notification + End +SMOS --> SMOF : RequestResponse + +@enduml + +``` + +![](21f9cff9cf31345d4411ac705209f5c0_img.jpg) + +**Service Management & Orchestration Framework (Subscriber)** + +Participants: SMOS Consumer, RNOAMF (NFCM SMOS), Service Management and Exposure, O-RAN NF + +**Register Configuration Management Services:** + +- 1 Create/Delete Modify/Query configuration +- 2 Discover Configuration Management Services +- 3 ServiceRequest + +**Creation** + +- 4 << O1 >> Creation +- 5 << O1 >> Success/Fail + +**Deletion** + +- 6 << O1 >> Deletion +- 7 << O1 >> Success/Fail + +**Modification** + +**alt [Use O1]** + +- 8 << O1 >> Modification +- 9 << O1 >> Success/Fail + +**opt [If a qualifying CM notification subscription exists]** + +- 10 CM Notification + +**[Use OpenFH M-Plane]** + +- 11 << OpenFH M-plane >> Modification +- 12 << OpenFH M-plane >> Success/Fail + +**opt [If a qualifying CM notification subscription exists]** + +- 13 CM Notification + +**Query** + +**opt [If retrieving config from O-RAN NF is needed]** + +**alt [Use O1]** + +- 14 << O1 >> get +- 15 << O1 >> the data + +**[Use OpenFH M-Plane]** + +- 16 << OpenFH M-plane >> get +- 17 << OpenFH M-plane >> the data + +**opt [If a qualifying CM notification subscription exists]** + +- 18 CM Notification + +- 19 RequestResponse + +## --- A.4 Use Case SO SMOS: SO dynamic resource orchestration + +Here, we focus on the role of the SO SMOS and the SO SMOS Producer interactions with other SMOSs, to fulfil the service orchestration request. + +The following SO SMOS capabilities are used for enabling dynamic resource orchestration: + +- SO SMOS exposes its service orchestration capabilities with the SME SMOS and consumes SME SMOS to discover other SMOSs it might need to consume. +- SO SMOS Producer supports the reception of service orchestration requests from SO SMOS Consumers e.g., non-RT RIC SMOF. +- SO SMOS Producer should be able to execute the service orchestration request received from the SO SMOS Consumers by decomposing the service orchestration request into appropriate management and orchestration actions, and consuming other SMOSs such as the NFCM SMOS, NFO SMOS, TE &IV SMOS, etc. +- SO SMOS Producer can determine the feasibility of executing received service orchestration request (e.g., orchestration policies can be used as part of a decision process). +- SO SMOS Producer can consume the NFCM SMOS to request configuration of the O-RAN NFs and to change the connection points configuration between O-RU and O-DU, O-DU and O-CU. +- When the SO SMOS Producer has to reduce the capacity of an O-RAN NF instance (e.g., to scale down, disable or terminate O-DU and O-CU instances), it determines the composition of the affected O-RAN NFs into their constituent NF Deployments. Then the SO SMOS Producer requests the identified LCM actions on each of the NF Deployments, by consuming the NFO SMOS. +- SO SMOS Producer can interact with Transport Network (TN) Managers (external to SMO). The SO SMOS Producer requests TN configuration changes to the network devices of TN that constitute the front-haul and mid-haul associated with O-RU, O-DU and O-CU connection, by consuming the external services exposed by a TN Manager. +- SO SMOS Producer can consume the TE & IV SMOS to update the RAN related topology information in the TE &IV repository upon successful completion of the service orchestration actions. + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | SO SMOS implements service orchestration based on the service orchestration request generated by the SO SMOS Consumer (e.g., an rApp). | | +| Actors and Roles | SME SMOS : Service Management and Exposure, described in sect. 5.4.
SO SMOS Consumer (e.g., rApp)
SO SMOS Producer
ORMO SMOF (NFO SMOS Producer), described in sect. 6.1.2
RAN NF OAM SMOF (NFCM SMOS Producer), described in section 6.1.1
TN Managers, external to SMO
TE & IV SMOS described in section 5.3. | | +| Assumptions | O2 interface connectivity is established between SMO and O-Cloud
O1 interface connectivity is established.
Network is operational. | | +| Pre-conditions | The rApp has discovered the SO SMOS capabilities via SME.
The SO SMOS Consumer (e.g., rApp) is an authorized consumer.
RAN NF OAM SMOF registered its NFCM SMOS capabilities with SME.
ORMO registered the NFO SMOS capabilities with SME.
TN Manager registered the TN Manager service capabilities with SME.
TE & IV SMOS is registered with SME. | | +| Begins when | The operator has made the decision to suspend unnecessary resources during off-peak hours.
The rApp has determined the service orchestration request it has to make to the SO SMOS Producer | | +| Step 1 (M) | SO SMOS Producer registers the SO SMOS capabilities with the SME. | | +| Step 2 (M) | After successful service registration, the SME SMOS Producer responds to SO SMOS Producer with the service profile ID. | | +| Step 3 (M) | The SO SMOS Consumer (e.g., rApp) determines that it needs to make a service orchestration request. The SO SMOS Consumer will consume services of the SME SMOS to discover the SO SMOS. | | +| Step 4 (M) | The SO SMOS Consumer uses the SO SMOS to make the request for shutdown and redeployment of several O-RAN NFs. | | +| Step 5 (M) | SO SMOS Producer determines the necessary actions for the service request, in this use case, these are configuration changes to O-RAN NFs and LCM actions on their constituent NF Deployment instances. | | +| Step 6 (M) | SO SMOS Producer performs the actions it identified by consuming the NFCM SMOS to make configuration changes to the O-RAN NFs. | | +| Step 7 (M) | SO SMOS Producer queries the latest topology information by consuming the TE & IV SMOS to find out which NF Deployment instances are related to the O-RAN NFs. | | +| Step 8 (M) | SO SMOS Producer performs the LCM actions it identified as appropriate on the respective NF Deployment instances (e.g., terminate) by consuming the NFO SMOS. | | + +| | | | +|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| Step 9 (M) | SO SMOS Producer performs the actions it identified by consuming the TN Management Service to make network setting changes to the front-haul and mid-haul. | | +| Step 10 (O) | SO SMOS notifies its SO SMOS Consumer (e.g., rApp) about the completion of the service orchestration actions. | | +| Ends when | The SO has completed the requested service orchestration actions. | | +| Exceptions | TBD | | +| Post Conditions | End | | + +``` + +@startuml +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +autonumber +Box "O-Cloud" #lightseagreen participant "DMS" as DMS participant "IMS" as IMS +End box +Box "Service Management and Orchestration Framework" #gold Participant "ORMO SMOS\n(NFO & FOCOM)" as ORMO Participant "RAN NF OAM SMOS" as OAM Participant "TE & IV SMOS" as TEIV Participant "SO SMOS" as TM Participant "SME SMOS" as SME Participant "Non-RT RIC SMOS" as nRT participant "rApp" as rAP +End box +Participant "TN Manager" as TNM +Box "O-RAN Nodes" #lightpink Participant "E2-Node(s)" as E2NODES +End box +group Service registration +Note over ORMO ORMO SMOS registers services related to Orchestration with SME +SMOEnd note ORMO -> SME : Register services +SME --> ORMO : Success (Service Profile ID) +Note over OAM RAN NF OAM SMOS registers services related to PM, FM ,CM with SME +SMOEnd note OAM -> SME : Register services +SME --> OAM : Success (Service Profile ID) +Note over TNM TN Management Service registers services +End note +TNM -> SME : Register services +SME --> TNM : Success (Service Profile ID) +Note over TEIV TE & IV SMOS registers services related to topology with SME +SMOEnd note TEIV -> SME : Register services +SME --> TEIV : Success (Service Profile ID) +Note over TM SO SMOS registers services related to orchestration with SME +SMOEnd note TM -> SME : Register services +SME --> TM : Success (Service Profile ID) +end +group Service discovery +Note over TM, nRT Non-RT RIC SMOS discovers RAN NF OAM SMOS with SME +SMOS.End note nRT -> SME : <> Discover RAN NF OAM SMOS +SME --> nRT : <> Discovery Result +Note over TM, nRT Non-RT RIC SMOS discovers TE & IV SMOS with SME +SMOS.End note nRT -> SME : <> Discover TEIV SMOS +SME --> nRT : <> Discovery Result +Note over TM, nRT Non-RT RIC SMOS discovers SO SMOS with SME +SMOS.End note nRT -> SME : <> Discover SO SMOS +SME --> nRT : <> Discovery Result +Note over TM, nRT SO SMOS discovers ORMO SMOS with SME +SMOS.End note TM -> SME : Discover ORMO SMOS +SME --> TM : Discovery Result +Note over TM, nRT SO SMOF discovers RAN NF OAM SMOS with SME +SMOS.End note TM -> SME : Discover RAN NF OAM SMOS +SME --> TM : Discovery Result +Note over TM, nRT SO SMOF discovers TN Manager Service with SME +SMOS.End note TM -> SME : Discover TN Manager Service +SME --> TM : Discovery Result +Note over TM, nRT SO SMOS discovers TE & IV SMOS with SME +SMOS.End note TM -> SME : Discover TEIV SMOS services +SME --> TM : Discovery Result +End +group Analysis +Note over nRT, rAP rApp gets PM data from RAN NF OAM +SMOEnd noterAP <-> OAM : Query and collect PM Data +rAP -> rAP : Estimate wireless bandwidth\n utilization for all cells to identify periods of low activity +rAP -> rAP : Monitor when topology changes occur +Note over nRT, rAP rApp gets topology from TE & IV +SMOEnd noterAP <-> TEIV : Query and collect topology Data +rAP -> rAP : Based on the current topology\n and the estimated wireless bandwidth utilization of all cells, \n rApp calculates the optimal topology to apply \nduring low operation from the viewpoint of power saving. +end +group Deployment +Note over nRT, rAP rApp requests service orchestration to SO +SMOEnd noterAP -> TM : Service Orchestration Request +TM -> TM : Decision of configuration change procedure +loop Repeat until deployment is complete +TM -> ORMO : Resource Deployment Request +ORMO <-> IMS : <> O2 action +ORMO <-> DMS : <> O2 action +ORMO -> TEIV : Notify O-cloud Information +TEIV --> ORMO : Confirm success +ORMO --> TM : Resource Deployment Response +TM -> OAM : Configuration change request +OAM <-> E2NODES : <> O1 action +OAM -> TEIV : Notify NF Information +TEIV --> OAM : Confirm success +OAM --> TM : Configuration change response +TM -> TNM : network change request +TNM -> TNM : Change switch setting +TNM -> TEIV : Notify Network Information +TEIV --> TNM : Confirm success +OAM --> TM : Configuration change response +endgroup +Inventory Update +TM -> TEIV : Query and collect topology Data +TEIV --> TM : Return topology Data +TM -> TM : Verify that topology Data\n has changed to that requested by rApp. +end +TM --> rAP : Service Orchestration Complete +group Option +SequencerAP + +``` + +``` + +-> TEIV : Query and collect topology Data +TEIV --> rAP : Return topology Data +rAP -> rAP : Verify that topology Data has changed to that requested by rApp.end +end +@enduml + +``` + +![Sequence diagram for O-RAN Decoupled SMO Architecture showing interactions between O-Cloud and O-RAN Nodes.](0d66e1d2186c3a813314836e79806886_img.jpg) + +The diagram illustrates the Service Management and Orchestration Framework (SMO) architecture, showing the interactions between the O-Cloud and O-RAN Nodes (E2-Node(s)). + +**O-Cloud Components:** OSMO SMO (INFO & FOCOM), RAN NF OAM SMO, TE & IV SMO, SO SMO, SME SMO, Non-RT RIC SMO, and rApp. + +**O-RAN Nodes:** E2-Node(s). + +**Sequence of Operations:** + +- Service registration:** + - OSMO SMO registers services related to Orchestration with SME SMO. + - 1 Register services + - 2 Success (Service Profile ID) + - RAN NF OAM SMO registers services related to PM FM CM with SME SMO. + - 3 Register services + - 4 Success (Service Profile ID) + - TN Management Service registers services + - 5 Register services + - 6 Success (Service Profile ID) + - TE & IV SMO registers services related to topology with SME SMO. + - 7 Register services + - 8 Success (Service Profile ID) + - SO SMO registers services related to orchestration with SME SMO. + - 9 Register services + - 10 Success (Service Profile ID) +- Service discovery:** + - Non-RT RIC SMO discovers RAN NF OAM SMO with SME SMO. + - 11 «RT» Discover RAN NF OAM SMO + - 12 «RT» Discovery Result + - Non-RT RIC SMO discovers TE & IV SMO with SME SMO. + - 13 «RT» Discover TEIV SMO + - 14 «RT» Discovery Result + - Non-RT RIC SMO discovers SO SMO with SME SMO. + - 15 «RT» Discover SO SMO + - 16 «RT» Discovery Result + - SO SMO discovers OSMO SMO with SME SMO. + - 17 Discover OSMO SMO + - 18 Discovery Result + - SO SMO discovers RAN NF OAM SMO with SME SMO. + - 19 Discover RAN NF OAM SMO + - 20 Discovery Result + - SO SMO discovers TN Management Service with SME SMO. + - 21 Discover TN Management Service + - 22 Discovery Result + - SO SMO discovers TE & IV SMO with SME SMO. + - 23 Discover TEIV SMO services + - 24 Discovery Result +- Analysis:** + - 25 Query and collect PM Data + - rApp gets PM data from RAN NF OAM SMO + - 26 Estimate wireless bandwidth utilization for all cells to identify periods of low activity + - 27 Monitor when topology changes occur + - 28 Query and collect topology Data + - rApp gets topology from TE & IV SMO + - 29 Based on the current topology and the estimated wireless bandwidth utilization of all cells, rApp calculates the optimal topology to apply during low operation from the viewpoint of power saving. +- Deployment:** + - 30 Service Orchestration Request + - 31 Decision of configuration change procedure + - rApp requests service orchestration to SO SMO + - 32 Resource Deployment Request + - 33 «Q2» Q2 action + - 34 «Q2» Q2 action + - 35 Notify O-cloud information + - 36 Confirm success + - 37 Resource Deployment Response + - 38 Configuration change request + - 39 «O1» O1 action + - 40 Notify NF information + - 41 Confirm success + - 42 Configuration change response + - 43 network change request + - 44 Change switch setting + - 45 Notify Network information + - 46 Confirm success + - 47 Configuration change response +- Inventory Update:** + - 48 Query and collect topology Data + - 49 Return topology Data + - 50 Verify that topology Data has changed to that requested by rApp. + - 51 Service Orchestration Complete +- Option Sequence:** + - 52 Query and collect topology Data + - 53 Return topology Data + - 54 Verify that topology Data has changed to that requested by rApp. + +Sequence diagram for O-RAN Decoupled SMO Architecture showing interactions between O-Cloud and O-RAN Nodes. + + + +# Annex: Change History + +| Date | Revision | Description | +|------------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.xx.yy | 01.00 | Published as Final version 01.00 | +| 2024.xx.yy | 02.00 | Published as Final version 02.00 | +| 2024-05-13 | V02.00.01 | Incorporated approved CR:
  • • CMCC-2023.12.01-WG1-CR-103-DEC_SMO-TR_addRecommandSolution_v07
| +| 2024-07-10 | V02.00.01 | Updated the SMO release title and file naming, from R003 to R004 | \ No newline at end of file diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/0af83e0dfa496cc337d2e037f9dab2e5_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/0af83e0dfa496cc337d2e037f9dab2e5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b25149faae501f68f423e3be26e849003171b762 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/0af83e0dfa496cc337d2e037f9dab2e5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b1be31b678647870f8266373d1a09fa154613663157ad36721064750ba5f9564 +size 36308 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/0e6106fa497db9119e5e0a46390eccb5_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/0e6106fa497db9119e5e0a46390eccb5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ef93ca9720b30028547a294d65d4176506f4faa3 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/0e6106fa497db9119e5e0a46390eccb5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b46010a995bba188e27bf94d27b1121723c0f4c3ffc899f877a4d50733c94a89 +size 41577 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/22353a834c1d92284324500cb212ae1e_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/22353a834c1d92284324500cb212ae1e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3b48866a07c6e6b777b0750051add4dde14e23d4 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/22353a834c1d92284324500cb212ae1e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4f1d8a287c382119d4b4bda2a066e26bd15b04d1457c5d2986bb4c5eeb505172 +size 58117 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/2406a74c5810c8e0511740583fcce9fe_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/2406a74c5810c8e0511740583fcce9fe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..31bd876ee569db4c3224a1156a8d490f62e1bec2 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/2406a74c5810c8e0511740583fcce9fe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:37cd3b1e92ca20a01ced59ae1b54084389c06ed6bf3345eb7ed852e06aa1fc55 +size 54101 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/2c0a83e404dead49ace89a79056c9fa8_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/2c0a83e404dead49ace89a79056c9fa8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9186c97c76e69eb6681b2f6653343d0059f72c62 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/2c0a83e404dead49ace89a79056c9fa8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4fefd808ad441be3e87256ac97b2e45f0bfdfd967ffb08a0022aa5da64d0959c +size 59977 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/2ff760a1f9141fea1f2e0e5372a7517e_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/2ff760a1f9141fea1f2e0e5372a7517e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..68ea75282dbd6239e363fb83d5d1c90105a49169 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/2ff760a1f9141fea1f2e0e5372a7517e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ba56c522458675ced31e8ac98d9dc3d1408d8f7f62c39f5d648fb6ef03ec8384 +size 21430 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/3a458358163869c525fbb29a1fbdaece_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/3a458358163869c525fbb29a1fbdaece_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b2f22af8185bdb92f4c4cefddb9127ac9c9b10fb --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/3a458358163869c525fbb29a1fbdaece_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b2dc35d7af1255b9ff3389f3387a607eaf85c7f0879076fbbfe40a7355090140 +size 44149 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/3ed906d2683ca5d795f98c233c3ab890_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/3ed906d2683ca5d795f98c233c3ab890_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..50c4c7e1de8ab5f5e1e7875509c18908ee77deec --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/3ed906d2683ca5d795f98c233c3ab890_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e391002b3a07688ce6926e93a2d20b3413071f857dc87e0ad0db6c4bdeb2006 +size 31262 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/43ed988dbee00c9bb44f4ed3d45971cc_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/43ed988dbee00c9bb44f4ed3d45971cc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6a5ba8afda9b7c041a7f57397b9daff9dcdb30e7 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/43ed988dbee00c9bb44f4ed3d45971cc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:91a22d6b5de3f6c69d0567c85fd6cfe2f6b40dcb54c0273db3f059e7cffc2d75 +size 38414 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/47ae93a1126ff13744b876f0997fbf03_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/47ae93a1126ff13744b876f0997fbf03_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0d40a52cd7df49e7cc66f67b63b8c63b36cde72d --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/47ae93a1126ff13744b876f0997fbf03_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3afd5329f1ca2198ab494e4ecf630fe3da4178655f555cf9fe34d1f20ef97ae3 +size 33324 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/594bc3aafabcc51cb96f2ebb85a0f343_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/594bc3aafabcc51cb96f2ebb85a0f343_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..952c989e46ced1809e2ed7b912f43df210ff2eca --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/594bc3aafabcc51cb96f2ebb85a0f343_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ebf33d6c16d6256f722a0e5a83e3f0221078bd6d2407f15689771ae4241ca078 +size 67284 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/6d12a8e64a3c8567f52aa3d94dc26716_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/6d12a8e64a3c8567f52aa3d94dc26716_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..faf3d3dff9141d311ebeaea5a93fb2c9c54ff4f8 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/6d12a8e64a3c8567f52aa3d94dc26716_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:034f69940b10947d7fa59759530b725b31acbdd87cc3246e8b6315be0d7ebc88 +size 26105 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/6f2d68847139b668f7cf85210ec852de_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/6f2d68847139b668f7cf85210ec852de_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8b9106b9400fe88f2e808312d3b31dcfbf1ed6b9 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/6f2d68847139b668f7cf85210ec852de_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:35410e37c32fb6dd3989dc225729d095dc04c2a0de0f5987eccb31945a99c623 +size 35006 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/77ffb9cd2d6005cab47f45cc0f5774ce_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/77ffb9cd2d6005cab47f45cc0f5774ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cef9543e3fc27158857d794a87697496cf1e807f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/77ffb9cd2d6005cab47f45cc0f5774ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6fba5dc7f635eb3c382ce236dee3a772ef515c25c1822e73508e21af1a8e3b47 +size 59598 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/958d0ce37a681fa643470763f78e5870_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/958d0ce37a681fa643470763f78e5870_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12dd587023d7fe149547daed995ff150403657c8 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/958d0ce37a681fa643470763f78e5870_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ba9a5ac47a83f410ac170cb785678be2962b1ea9bcd7ee80fb3200d2109c503a +size 46101 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a2bf249fa86d93dbee4354259e850c88_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a2bf249fa86d93dbee4354259e850c88_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..15798e5e8221c879f5287a3eafc93b3f0ffa6878 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a2bf249fa86d93dbee4354259e850c88_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:359aa948fc9647e7f2e3cfb415ee9c3128ed4fbea28a126cdc6ee9044888ecc7 +size 36776 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a4fda10a8f2a7ed99774f33136b228c6_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a4fda10a8f2a7ed99774f33136b228c6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..88e6d7dd68f14a96974de82170f269920d62c476 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a4fda10a8f2a7ed99774f33136b228c6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5bf7576a95c4108e693536883b25c059feaf092549dce7b95ae89706b02e210b +size 52748 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a6fb5b9ccab46ca12a23b3d10ed04a2a_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a6fb5b9ccab46ca12a23b3d10ed04a2a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3db9e911595e58d8dc458248bd03a33474044fb4 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/a6fb5b9ccab46ca12a23b3d10ed04a2a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e90a853ec9529b52a339200a6ade0d46283d2821fb48a67021b324abe10d9154 +size 17595 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ab03ecad666ebbea98b159d985be7c37_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ab03ecad666ebbea98b159d985be7c37_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7dec32bf09b1f793de839d9ecee7aa94ef935dfd --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ab03ecad666ebbea98b159d985be7c37_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b012f6dbeb17adc3ed98dc807161e4b46b6f276c20e8641b7fa95e1bcce9661c +size 40535 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ad72dbfc1a166edf763ed5eeaaf46e01_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ad72dbfc1a166edf763ed5eeaaf46e01_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..839eed1f787f21d7741f68125cd258c31c739243 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ad72dbfc1a166edf763ed5eeaaf46e01_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4aede53512b1c18a196ce521b368756c10ca5e32329d59f6f42da8a294517ee9 +size 27937 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/aff57c583736b2909b84037b38d635e5_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/aff57c583736b2909b84037b38d635e5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0d9912f94b605d7c3fca2f380f0d484bf9f06884 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/aff57c583736b2909b84037b38d635e5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c83a49a28e6a9431c0cdb2854176b53db1a2e522b503852d2fda2aa506184133 +size 24435 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/c8a977d414f17a853d76c662eb53e281_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/c8a977d414f17a853d76c662eb53e281_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a4eb53dac7fc97cc41871b71488feb9e0fa6185d --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/c8a977d414f17a853d76c662eb53e281_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:310ade1f15ec01be7285dc53d1b50e719c3bb67c48d765a2d44aac5460e44c77 +size 31763 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/cc13ae415ca9b115ad938e43d646091d_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/cc13ae415ca9b115ad938e43d646091d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..24542ba497129d6c772f593189a5d7bed666b519 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/cc13ae415ca9b115ad938e43d646091d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e3c255921f1c451081caf033378ba8dbcf868972b509e5e8cdbd466717ff9044 +size 23329 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/cdaad324ca873164ca37acfde92a7f30_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/cdaad324ca873164ca37acfde92a7f30_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b6242233afcf74a65d0c015d3ff336f6654e3ed1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/cdaad324ca873164ca37acfde92a7f30_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8c7ea8c21cdeaa294996adbd62561c68b7df294c1a151019571b315cb3a5497a +size 38433 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ce450c78adf312551d6f877c81f38cb1_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ce450c78adf312551d6f877c81f38cb1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a443f85e0b4264902b79b1a26759372493c6e00f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ce450c78adf312551d6f877c81f38cb1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:91f370c31499e472cf66d77a4da1f8ef5b4aea9c9d50b64c01da23262eda669d +size 37106 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/d35debfed86bf68a10d57905ac72a936_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/d35debfed86bf68a10d57905ac72a936_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9a7bc98e3c39a5b86af482daf492cf3568b7089c --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/d35debfed86bf68a10d57905ac72a936_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:524a9ff37641fcffa5740b084f8421420e4f78e0888ee1c835b4c0bda70796d5 +size 32900 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/d897adb34077ec171cdca43660553816_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/d897adb34077ec171cdca43660553816_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c411fdfe8019dd64f02c7deb41e10f35538c0625 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/d897adb34077ec171cdca43660553816_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dda44afe5c5162f451492e01cfd0817ae129a701abb5397745573dd20f83ee55 +size 30743 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/e082d7745219ae62560019b9cd4375c6_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/e082d7745219ae62560019b9cd4375c6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bae0ea3a34a552555b02124802ba4acdb388f8fa --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/e082d7745219ae62560019b9cd4375c6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c557678c814e63a624bdc4233aabdc9c04b404cc3d367f0c06132802e08cebe2 +size 48423 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/e0e3c20519c7abc406f301d14ab88d2b_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/e0e3c20519c7abc406f301d14ab88d2b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4db689b9ce9381773aaf8cc0efa9bf1f24f0bf0b --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/e0e3c20519c7abc406f301d14ab88d2b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cfb2f93db7f28ff79af62108e4dc67f71c24c4e129fb9cfc027496ce51ab7b1a +size 82690 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/e3ff0c4aa51f7a73eea2194b96a2d40c_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/e3ff0c4aa51f7a73eea2194b96a2d40c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..682a47709d2c523618006eec4a128c6bcfe58260 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/e3ff0c4aa51f7a73eea2194b96a2d40c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:52056bc9d5d7b5a241170697be564e352d8f4af9a2eb6fa427396222988c9f21 +size 34844 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ed0933c87b10f74570e0f6f2b971880b_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ed0933c87b10f74570e0f6f2b971880b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6b2b8d921f0e9ed61c4ae8d54ea3670ae7574003 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/ed0933c87b10f74570e0f6f2b971880b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9d28c92e5773b518f613e5ea9dcfd9df31e6babec842820b2ec9608281153be7 +size 69919 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/f2b2637a2253bd66f62938967ef1dd30_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/f2b2637a2253bd66f62938967ef1dd30_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f63cde543dd4d7629ef0a45e22bf24a1c2c9914 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/f2b2637a2253bd66f62938967ef1dd30_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b597498c8684b4e9285c565645c4d0ee9c271ef43adc8cc08bdd28b23ed83b8c +size 37310 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/f6f72526c37da1cd4d0fd6d87b7c5c8d_img.jpg b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/f6f72526c37da1cd4d0fd6d87b7c5c8d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6ef4aefa9b2576d377dc509a00cd41ef4cf8a8cc --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/f6f72526c37da1cd4d0fd6d87b7c5c8d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dcecb8e32a2076668735c2f3abbb9491e8d402e34e1546743988490ab6494c56 +size 19773 diff --git a/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/raw.md b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..e7ccdf5f0c0dde1bf6625214084bb42dc54c4bee --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00/raw.md @@ -0,0 +1,1163 @@ + + +# --- **O-RAN Work Group 1 (Use Cases and Overall Architecture)****Spectrum Aggregation for Multi-Vendor Deployments** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|---------------------------------------------------------------------------|----| +| Foreword ..... | 4 | +| Modal verbs terminology ..... | 4 | +| Executive summary ..... | 4 | +| 1 Scope..... | 5 | +| 2 References..... | 5 | +| 2.1 Normative references ..... | 5 | +| 2.2 Informative references..... | 5 | +| 3 Definition of terms, symbols and abbreviations ..... | 6 | +| 3.1 Terms..... | 6 | +| 3.2 Symbols..... | 6 | +| 3.3 Abbreviations ..... | 6 | +| 4 Objectives and requirements..... | 7 | +| 4.1 Current challenges for spectrum aggregation in multi-vendor RAN ..... | 7 | +| 4.2 Objectives..... | 7 | +| 5 Scenarios and considerations ..... | 8 | +| 5.1 Overview ..... | 8 | +| 5.2 Deployment scenarios ..... | 9 | +| 5.2.1 Co-located deployments ..... | 9 | +| 5.2.2 Non-co-located deployments..... | 10 | +| 5.2.3 Transport assumptions..... | 12 | +| 5.3 Considerations for spectrum aggregation techniques..... | 12 | +| 5.3.1 UE considerations from network perspective..... | 12 | +| 5.3.2 Spectrum considerations..... | 13 | +| 5.3.3 Synchronization considerations..... | 16 | +| 5.3.4 Network management considerations..... | 16 | +| 5.3.5 RAN intelligence considerations ..... | 17 | +| 5.3.6 Considerations for solution evaluation ..... | 17 | +| 6 Spectrum aggregation solutions ..... | 18 | +| 6.1 Overview ..... | 18 | +| 6.2 Solution 1: Intra O-DU Carrier Aggregation ..... | 19 | +| 6.2.1 Solution description..... | 19 | +| 6.2.2 Mapping to deployment scenarios and other consideration ..... | 21 | +| 6.2.3 Impact analysis on specifications ..... | 21 | +| 6.2.4 Feasibility and gain/complexity analysis..... | 21 | +| 6.3 Solution 2: Inter O-DU Carrier Aggregation ..... | 22 | +| 6.3.1 Solution description..... | 22 | +| 6.3.2 Mapping to deployment scenarios and other consideration ..... | 27 | +| 6.3.3 Impact analysis on specifications ..... | 28 | +| 6.3.4 Feasibility and gain/complexity analysis..... | 28 | +| 6.4 Solution 3: Dual Connectivity..... | 30 | +| 6.4.1 Solution description..... | 30 | +| 6.4.2 Mapping to deployment scenarios and other consideration ..... | 31 | +| 6.4.3 Impact analysis on specifications ..... | 32 | +| 6.4.4 Feasibility and gain/complexity analysis..... | 32 | +| 7 Conclusions and recommendations..... | 32 | +| 7.1 Summary of evaluation ..... | 32 | +| 7.2 Impact on standardization ..... | 36 | +| 7.3 Recommendations ..... | 36 | +| Annex A: Xhaul delay considerations..... | 37 | + +| | | +|---------------------------------------------------------------------|----| +| Annex B: Examples of multi-vendor Inter O-DU interface ..... | 39 | +| B.1 DL CA using an Inter O-DU interface ..... | 39 | +| B.2 High-level description of Inter O-DU interface (D2) ..... | 39 | +| Annex C: Spectrum aggregation solution decision tree analysis ..... | 42 | +| Annex: Change history/Change request (history) ..... | 44 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +--- + +# Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Executive summary + +Spectrum aggregation across different bands plays an essential role for enhancing user experience and efficient use of frequency resources. As MNOs get access to new NR spectrum, they usually desire to aggregate the capacity across the different bands. The present document aims to identify practical scenarios for spectrum aggregation across equipment from multiple network equipment vendors. The spectrum aggregation scenarios cover a variety of deployment cases. The present document considers scenarios where different O-RAN NFs can be co-located or non-co-located. Supplementary spectrum aggregation scenarios such as SUL, SDL deployment are also covered. Different considerations for spectrum combinations, UE requirements and solution evaluation criteria are also documented. + +To address spectrum aggregation in multi-vendor RAN deployment scenarios, three solutions are described: Intra O-DU CA, Inter O-DU CA, and Dual Connectivity. The solutions are mapped to different deployment scenarios and analyzed based on the evaluation criteria. While the Intra O-DU CA and Dual Connectivity scenarios are covered in existing O-RAN and 3GPP specifications, the present document also covers the requirements for supporting a newly proposed Inter O-DU CA solution along with a brief outline for the solution architecture. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document describes different deployment scenarios that can benefit from spectrum aggregation in a multi-vendor network deployment. Various solutions for spectrum aggregation are also studied. + +# --- 2 References + +## 2.1 Normative references + +Not applicable. + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regards to a particular subject area. + +- [i.1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [i.2] O-RAN.WG9.XTRP-REQ-v01.00: "Xhaul Transport Requirements". +- [i.3] 3GPP TS 38.801 v 14.0.0, 03/2017: "Study on new radio access technology: Radio access architecture and interfaces". +- [i.4] 3GPP TS 38.300: "5G; NR; NR and NG-RAN Overall description; Stage-2". +- [i.5] 3GPP TS 38.101-1: "NR; User Equipment (UE) radio transmission and reception; Part 1: Range 1 Standalone". +- [i.6] 3GPP TS 38.133: "NR; Requirements for support of radio resource management". +- [i.7] +- [i.8] +- [i.9] 3GPP TS 38.331: "5G; NR; Radio Resource Control (RRC) Protocol specification". + +- [i.10] 3GPP TS 38.420: "5G; NG-RAN; Xn general aspects and principles". +- [i.11] 3GPP TS 38.101-3: "NR; User Equipment (UE) radio transmission and reception; Part 3: Range 1 and Range 2 Interworking operation with other radios". +- [i.12] 3GPP TS 38.473; F1 application protocol. +- [i.13] 3GPP TS 38.423; Xn application protocol. +- [i.14] O-RAN ALLIANCE O-RAN.WG4.CUS.0: "Control, User and Synchronization Plane Specification". +- [i.15] O-RAN ALLIANCE O-RAN.WG4.MP.0: "Management Plane Specification". +- [i.16] O-RAN ALLIANCE O-RAN.WG1. Use-Cases-Detailed-Specification: "Use Cases Detailed Specification". +- [i.17] O-RAN.WG1.OAD, "O-RAN Architecture Description". + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in [i.1], O-RAN WG1.OAD [i.17] and the following apply: + +**carrier aggregation:** aggregation of two or more NR or E-UTRA component carriers in order to support wider transmission bandwidths. + +**Primary O-DU:** O-DU where PCell is hosted for a particular UE. + +**Secondary O-DU:** O-DU where SCell is hosted for a particular UE. + +## 3.2 Symbols + +For the purposes of the present document, the symbols given in [i.1] and the following apply: + +$N_{RB}$ Transmission bandwidth configuration, expressed in units of resource blocks (for E-UTRA) + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in [i.1], O-RAN WG1.OAD [i.17] and the following apply: + +| | | +|-------------|-------------------------------------------| +| C&M Plane | Control and Management Plane | +| C-RAN | Centralized RAN | +| C-RNTI | Cell Radio Network Temporary Identifier | +| D-RAN | Distributed RAN | +| EMS | Element Management System | +| MCG | Master Cell Group | +| MNO | Mobile Network Operator | +| Near-RT RIC | Near real time RAN Intelligent Controller | +| Non-RT RIC | Non-real time RAN Intelligent Controller | +| PCI | Physical Cell Identity | +| SCG | Secondary Cell Group | +| SMO | Service Management and Orchestration | +| vRAN | Virtualized RAN | + +# --- 4 Objectives and requirements + +## 4.1 Current challenges for spectrum aggregation in multi-vendor RAN + +Spectrum aggregation across different bands plays an essential role for user experience and efficient use of frequency resources. As MNOs get access to new NR spectrum, they usually desire to aggregate the capacity across the different bands to improve the user experience. The coverage areas of different frequency bands can be very different. There has been interest from several companies for spectrum aggregation over multi-vendor RAN deployment, where different bands may have different component suppliers. In addition to a greenfield multi-vendor RAN deployment, how spectrum can be aggregated when a new band with a new supplier(s) is introduced in an existing network is an area of potential interest. + +## 4.2 Objectives + +The present document captures the outcome of the WG1 spectrum aggregation study across multi-vendor RAN equipment. The objective of the study is to document various deployment scenarios for spectrum aggregation and then describe solutions that map to these deployment scenarios. The solution evaluation under various considerations defined in the present document is also part of the study. + +The detailed objectives of this study item are: + +- 1) Capture and document multi-vendor deployment scenarios to support spectrum aggregation in various RAN configurations such as + - a. Centralized RAN, + - b. Distributed RAN, + - c. Virtualized RAN, + - d. Legacy RAN (i.e., already deployed). +- 2) Capture and document spectrum aggregation use cases: + - a. Intra-band contiguous and non-contiguous in FR1/FR2, + - b. Inter-band within and across FR1/FR2, + - c. Duplexing schemes (FDD/TDD). +- 3) Capture the spectrum considerations and UE considerations for different spectrum aggregation techniques. +- 4) Identify and document the evaluation criteria for the different spectrum aggregation techniques such as: + - a. Minimize complexity, e.g., required interface bandwidth and latency, + - b. Minimize impact to inter-operability testing and standardization effort, + - c. Increase performance and lower latency, + - d. Minimize impact on O-RAN architecture, + - e. Minimize UE impact, + - f. Aligns with 3GPP RAN design, + - g. Increase spectral efficiency of combined carriers, + - h. Increase coverage, + - i. Address security concerns with different solutions. + +- 5) Identify the different solutions possible for spectrum aggregation: + - a. Dual connectivity, + - b. Intra O-DU CA (Multi O-RU or Shared O-RU), + - c. Inter O-DU CA. +- 6) Identify the different interfaces used for supporting the spectrum aggregation techniques such as + - a. Xn Interface (Dual connectivity), + - b. F1 Interface (Dual connectivity), + - c. LLS interface (Intra O-DU CA), + - d. D2 Interface (Proposed interface to support Inter O-DU CA). +- 7) Evaluate and compare the solutions defined in 5) against the evaluation criteria mentioned in 4). +- 8) Briefly cover the outline of the proposed Inter O-DU CA solution. + +# 5 Scenarios and considerations + +## 5.1 Overview + +In its most general form, deployed RAN network functions in an MNO's network can be sourced from a single-vendor or multiple vendors. The connectivity between the RAN logical functions may need to consider ideal and non-ideal transport scenarios. RAN deployments can also be mixed involving a combination of D-RAN, C-RAN and vRAN deployments. + +Figure 5.1-1 shows the reference deployment architecture used in the present document. In addition to being purpose-built or virtualized, gNB network functions can be procured from multiple vendors. Depending on deployment factors, O-DUs can be connected to the same or different O-CU-CPs and O-CU-UPs. + +![Figure 5.1-1: Multi-vendor equipment deployment architecture. The diagram shows a network architecture where multiple O-DUs are connected to two O-CU-UPs and one O-CU-CP. The O-CU-UPs are connected to NG-U and Xn-U, while the O-CU-CP is connected to NG-C and Xn-C. The O-DUs are connected to O-RU1, O-RU2, and O-RUn via O-FH interfaces. The O-CU-UPs and O-CU-CP are connected to the O-DUs via F1-U and F1-C interfaces respectively.](cc13ae415ca9b115ad938e43d646091d_img.jpg) + +``` + +graph TD + NGU[NG-U] --- OCUUP1[O-CU-UP] + NGU --- OCUUP2[O-CU-UP] + NGC[NG-C] --- OCUCP[O-CU-CP] + XnU[Xn-U] --- OCUUP1 + XnU --- OCUUP2 + XnC[Xn-C] --- OCUCP + OCUUP1 --- E1[E1] --- OCUCP + OCUUP1 --- F1U[F1-U] --- ODUs[O-DU] + OCUUP2 --- F1U --- ODUs + OCUCP --- F1C[F1-C] --- ODUs + ODUs --- OFH[O-FH] --- ORU1[O-RU1] + ODUs --- OFH --- ORU2[O-RU2] + ODUs --- OFH --- ORUn[O-RUn] + +``` + +Figure 5.1-1: Multi-vendor equipment deployment architecture. The diagram shows a network architecture where multiple O-DUs are connected to two O-CU-UPs and one O-CU-CP. The O-CU-UPs are connected to NG-U and Xn-U, while the O-CU-CP is connected to NG-C and Xn-C. The O-DUs are connected to O-RU1, O-RU2, and O-RUn via O-FH interfaces. The O-CU-UPs and O-CU-CP are connected to the O-DUs via F1-U and F1-C interfaces respectively. + +**Figure 5.1-1: Multi-vendor equipment deployment architecture** + +## 5.2 Deployment scenarios + +### 5.2.1 Co-located deployments + +#### 5.2.1.1 Overview + +This clause considers the deployment scenarios where relevant O-RAN network functions for aggregation of frequencies are co-located. In this use case, O-RAN NFs from multiple vendors, supporting the same or different band/duplexing capability are co-located. O-RAN NFs can be supporting a split RAN architecture, or it can be a monolithic integrated gNB. By supporting spectrum aggregation across the O-RAN NFs that are co-located, user throughput, cell coverage etc. can be improved. + +Use cases based on different combinations of O-RAN NFs are described in clause 5.2.1.2 and 5.2.1.3. + +#### 5.2.1.2 Addition of new O-RAN NFs co-located with existing intra/inter-band O-RAN NFs supporting same/different duplexing capability + +The following use case covers the scenario where spectrum aggregation is needed between the co-located O-RAN NFs. + +An MNO can have network function such as O-CU-CP, O-CU-UP, O-DU and O-RU with either TDD or FDD or both duplexing capabilities installed at a cell site. To increase the capacity of the site, MNO may need to install a new cell which could be operating in the same/different band. In one deployment scenario, depicted in Figure 5.2.1.2-1, MNO deploys a new O-RU, from a new vendor, to add a new frequency band to the existing infrastructure. The new O-RU can be connected to the existing O-DU through open fronthaul, as shown in Figure 5.2.1.2-1(b). In some instances, hardware or software realizing the existing O-DU may be limited by capacity and cannot host the new cell. One of the options available for the MNO is to enhance the capacity of existing hardware or software. Another possibility is to install a new hardware or software for capacity enhancements. The new hardware can be integrated with the existing hardware to realize the same logical O-DU (as in Figure 5.2.1.2-1(b)), or it can realize a new logical O-DU operating in parallel to the first O-DU as shown in Figure 5.2.1.2-1(c). + +![Figure 5.2.1.2-1: Adding new O-RU to support a new frequency band or carrier in a co-located deployment. (a) existing deployment. (b) addition of new O-RU. (c) addition of new O-RU and O-DU.](0e6106fa497db9119e5e0a46390eccb5_img.jpg) + +The diagram illustrates three deployment scenarios for adding new O-RAN network functions (NFs) to an existing co-located deployment. The components shown are NG (Next Generation Core), O-CU-UP/O-CU-CP (Control User Plane/Control Plane), O-DU (Distributed Unit), O-RU (Radio Unit), and UE (User Equipment). + +- (a) Existing deployment:** The NG is connected to O-CU-UP/O-CU-CP via F1. O-CU-UP/O-CU-CP is connected to O-DU1 via F1. O-DU1 is connected to O-RU1 and O-RU2 via O-FH (Open Fronthaul). O-RU1 and O-RU2 are connected to the UE. +- (b) Addition of new O-RU:** An arrow labeled "Add new carrier" points to this scenario. The NG is connected to O-CU-UP/O-CU-CP via F1. O-CU-UP/O-CU-CP is connected to O-DU1 via F1. O-DU1 is connected to O-RU1, O-RU2, and O-RUn via O-FH. O-RU1, O-RU2, and O-RUn are connected to the UE. O-RUn is labeled "New vendor". +- (c) Addition of new O-RU and O-DU:** The NG is connected to O-CU-UP/O-CU-CP via F1. O-CU-UP/O-CU-CP is connected to O-DU1 and O-DUn via F1. O-DU1 is connected to O-RU1 and O-RU2 via O-FH. O-DUn is connected to O-RUn via O-FH. O-RU1, O-RU2, and O-RUn are connected to the UE. O-DUn and O-RUn are labeled "New vendor". + +Figure 5.2.1.2-1: Adding new O-RU to support a new frequency band or carrier in a co-located deployment. (a) existing deployment. (b) addition of new O-RU. (c) addition of new O-RU and O-DU. + +**Figure 5.2.1.2-1: Adding new O-RU to support a new frequency band or carrier in a co-located deployment. (a) existing deployment. (b) addition of new O-RU. (c) addition of new O-RU and O-DU.** + +In some other deployment scenarios, deployed O-DU(s) may have limited capacity, may only support one duplexing method or can support a limited set of subcarrier spacing for real-time processing. The MNO may choose to deploy a new O-DU vendor to support a new O-RU, e.g., vendor c as shown in Figure 5.2.1.2-2. If the MNO chooses to install a new O-DU, it can be supporting the same or different duplexing capability or subcarrier spacing. If O-CU-CP and O- + +CU-UP are capable to handle the newly installed O-DU, the new O-DU can be connected to same O-CU-CP and O-CU-UP. Otherwise, a new O-CU-CP and O-CU-UP may also need to be installed. The MNO can choose the O-CU-CPs, O-CU-UPs, O-DUs or O-RUs from the same vendor or different vendors. + +![Figure 5.2.1.2-2: Spectrum aggregation in co-located O-DU. The diagram shows a network architecture where three O-DUs (O-DU2, O-DU1, O-DU3) are co-located at a single site. O-DU2 is from vendor b, O-DU1 is from vendor a, and O-DU3 is from vendor c. Each O-DU is connected to an O-CU-CP/O-CU-UP pair (O-CU-CP1/O-CU-UP1, O-CU-CP2/O-CU-UP2) via F1-C/F1-U interfaces. The O-CU-CPs are connected to the NG interface. The O-DUs are connected to O-RUs (O-RU2, O-RU1, O-RU3) via Open FH interfaces. The O-RUs are connected to a UE (User Equipment).](d35debfed86bf68a10d57905ac72a936_img.jpg) + +Figure 5.2.1.2-2: Spectrum aggregation in co-located O-DU. The diagram shows a network architecture where three O-DUs (O-DU2, O-DU1, O-DU3) are co-located at a single site. O-DU2 is from vendor b, O-DU1 is from vendor a, and O-DU3 is from vendor c. Each O-DU is connected to an O-CU-CP/O-CU-UP pair (O-CU-CP1/O-CU-UP1, O-CU-CP2/O-CU-UP2) via F1-C/F1-U interfaces. The O-CU-CPs are connected to the NG interface. The O-DUs are connected to O-RUs (O-RU2, O-RU1, O-RU3) via Open FH interfaces. The O-RUs are connected to a UE (User Equipment). + +**Figure 5.2.1.2-2: Spectrum aggregation in co-located O-DU** + +#### 5.2.1.3 Co-located intra/inter-band monolithic gNBs with same or different duplexing capability + +This use case covers the deployment scenario where a monolithic gNB is installed at cell site. As shown in Figure 5.2.1.3-1, to increase the user capacity with spectrum aggregation, the MNO can install additional hardware and software either to upgrade the capacity of exiting gNB or to support a new gNB operating in parallel to the existing gNB. The newly installed gNB can operate in the same band or different band as the existing gNB. Both the gNBs may also support same or different duplexing capability. The new gNB can be monolithic or disaggregated. By supporting spectrum aggregation between these gNBs, improved coverage and throughput can be achieved. + +![Figure 5.2.1.3-1: Spectrum aggregation in co-located gNBs. The diagram shows a network architecture where three gNBs (gNB2, gNB1, gNB3) are co-located at a single site. gNB2 is from vendor b, gNB1 is from vendor a, and gNB3 is from vendor c. Each gNB is connected to the NG interface. The gNBs are connected to a UE (User Equipment) via Xn interfaces.](f6f72526c37da1cd4d0fd6d87b7c5c8d_img.jpg) + +Figure 5.2.1.3-1: Spectrum aggregation in co-located gNBs. The diagram shows a network architecture where three gNBs (gNB2, gNB1, gNB3) are co-located at a single site. gNB2 is from vendor b, gNB1 is from vendor a, and gNB3 is from vendor c. Each gNB is connected to the NG interface. The gNBs are connected to a UE (User Equipment) via Xn interfaces. + +**Figure 5.2.1.3-1: Spectrum aggregation in co-located gNBs** + +### 5.2.2 Non-co-located deployments + +This clause covers the deployment scenarios where aggregated frequencies are served by equipments that are not co-located. + +In this use case, gNBs are supporting split RAN architecture and it is distributed into different O-RAN network functions. O-CU-CP/O-CU-UP might be residing at a centralized location while O-DUs may be located at cell site or at a central location. Two cases are considered for this scenario: + +- Single O-CU-CP and O-CU-UP connected to multiple O-DUs located at cell site. +- Each O-DU at cell site is connected to different O-CU-CP and O-CU-UP. + +In one deployment scenario, the network MNO may deploy a new O-RU from a different vendor, to add a new frequency band, that is not co-located with other O-RUs serving the same geographic area. As an example, currently deployed O-RUs in a network may serve a large area and the MNO may decide to serve a high-demand zone within the larger coverage area by deploying additional spectrum. This is shown in Figure 5.2.2-1 below. By supporting spectrum aggregation across all the O-RUs serving the same area, user throughput, cell coverage etc. can be improved. + +![Figure 5.2.2-1: Deploying additional O-RU in a non-co-located manner. (a) existing deployment. (b) addition of non-co-located O-RU connected to existing O-DU. (c) addition of non-co-located O-RU and O-DU.](43ed988dbee00c9bb44f4ed3d45971cc_img.jpg) + +The diagram illustrates three network architectures for O-RAN deployment: + +- (a) Existing deployment:** A central NG interface connects to an O-CU-UP/O-CU-CP block. This block connects via F1 to an O-DU1 block. O-DU1 connects via O-FH to two co-located O-RUs (O-RU1 and O-RU2) from Vendor a. These O-RUs serve a UE. +- (b) Addition of non-co-located O-RU connected to existing O-DU:** An arrow labeled "Add new carrier" points from (a) to (b). In (b), the same O-CU-UP/O-CU-CP block connects via F1 to O-DU1. O-DU1 now connects via O-FH to three O-RUs: O-RU1, O-RU2 (co-located, Vendor a) and a new O-RUn (non-co-located, New vendor). All three O-RUs serve the UE. +- (c) Addition of non-co-located O-RU and O-DU:** In (c), the O-CU-UP/O-CU-CP block connects via F1 to two O-DUs: O-DU1 and O-DUn (non-co-located). O-DU1 connects via O-FH to O-RU1 and O-RU2 (co-located, Vendor a). O-DUn connects via O-FH to O-RUn (non-co-located, New vendor). All O-RUs serve the UE. + +Figure 5.2.2-1: Deploying additional O-RU in a non-co-located manner. (a) existing deployment. (b) addition of non-co-located O-RU connected to existing O-DU. (c) addition of non-co-located O-RU and O-DU. + +**Figure 5.2.2-1: Deploying additional O-RU in a non-co-located manner. (a) existing deployment. (b) addition of non-co-located O-RU connected to existing O-DU. (c) addition of non-co-located O-RU and O-DU.** + +In some other deployment scenarios, as shown in Figure 5.2.2-2 below, deployed O-DU(s) at each cell site may have limited capacity, or may only support one duplexing method, or can support a limited set of subcarrier spacing. There may also be some other O-DUs which are not co-located with the existing O-DUs. But these O-DUs can be used together to overcome the limitations of existing cell site deployment. All the O-DUs can be supporting the same or different duplexing capability. The O-DUs can be connected to the same or different O-CU-CPs and O-CU-UPs. Also, these O-DUs may be provided by the same vendor or different vendors. The band configuration also can be the same or different for all these O-DUs. By supporting spectrum aggregation across different cells served by same or different non-co-located network functions (O-RU, O-DU, O-CU-CP, O-CU-UP), end user throughput and cell coverage of different frequency bands can be improved. + +![Figure 5.2.2-2: Spectrum aggregation in non-co-located RAN components. The diagram shows a network architecture with two Data Centers connected via Xn. Each Data Center contains O-CU-CP and O-CU-UP blocks. These are connected to three Cell Sites (Cell Site 2, Cell Site 1, and Cell Site 3) via F1-C and F1-U interfaces. Cell Site 2 (vendor b) has O-DU2 (FDD), Cell Site 1 (vendor a) has O-DU1 (TDD), and Cell Site 3 (vendor c) has O-DU3 (TDD). Each Cell Site is connected to an O-RU (O-RU2, O-RU1, O-RU3) via Open Fronthaul. All O-RUs are connected to a UE (User Equipment).](2c0a83e404dead49ace89a79056c9fa8_img.jpg) + +Figure 5.2.2-2: Spectrum aggregation in non-co-located RAN components. The diagram shows a network architecture with two Data Centers connected via Xn. Each Data Center contains O-CU-CP and O-CU-UP blocks. These are connected to three Cell Sites (Cell Site 2, Cell Site 1, and Cell Site 3) via F1-C and F1-U interfaces. Cell Site 2 (vendor b) has O-DU2 (FDD), Cell Site 1 (vendor a) has O-DU1 (TDD), and Cell Site 3 (vendor c) has O-DU3 (TDD). Each Cell Site is connected to an O-RU (O-RU2, O-RU1, O-RU3) via Open Fronthaul. All O-RUs are connected to a UE (User Equipment). + +**Figure 5.2.2-2: Spectrum aggregation in non-co-located RAN components** + +### 5.2.3 Transport assumptions + +This clause covers the aspect of connectivity between the different equipment for supporting spectrum aggregation to consider ideal and non-ideal transport considerations. + +Network devices can be connected directly or through L2/L3 switches within the range that meets delay requirements. There are multiple connectivity classes for the transport connecting the NFs. Some guidelines are provided in O-RAN Xhaul Transport Requirements document [i.2]. + +For more information on the latency requirements, see Annex A. The outlined solutions in the present document account for ideal and non-ideal transport scenarios. + +## 5.3 Considerations for spectrum aggregation techniques + +### 5.3.1 UE considerations from network perspective + +Spectrum aggregation between RAN NFs can be achieved by multiple techniques such as carrier aggregation or dual connectivity. The usage of these techniques in a network are also dependent on UE capability. Different spectrum aggregation techniques can impact the UE performance differently. Use case considerations for UE performance and capabilities are discussed below. + +- Spectrum aggregation to maximize component carrier (CC) combinations based on UE capability: Number of carrier frequency combinations play an important role in spectrum aggregation; larger the number, better the throughput and coverage. UEs supporting different 3GPP releases differ in CC combination capabilities. Number of available CCs for spectrum aggregation depends on a particular spectrum aggregation technique. For example, UEs, which are supporting earlier R15 or R16 3GPP releases, may be limited in supporting CC combinations for some of the spectrum aggregation techniques based on the band and bandwidth considerations for the component carriers. This needs to be considered for both SA and NSA UEs. +- UE power consumption: While considering spectrum aggregation techniques, power consumption by UEs at various distances from the cell site needs to be considered. Spectrum aggregation techniques should minimize impact on UE power consumption. + +### 5.3.2 Spectrum considerations + +#### 5.3.2.1 Overview + +Most commercial RAN deployments involve multiple frequency bands. Spectrum aggregation across different bands should consider frequency band characteristics (coverage, supported SCS, duplexing). + +The following clauses cover use cases, such as (i) intra-band contiguous and non-contiguous in FR1/FR2, (ii) inter-band within and across FR1/FR2, and (iii) considerations for DL-UL link balance in high-frequency bands and different duplexing schemes (FDD/TDD). + +#### 5.3.2.2 Duplexing (FDD/TDD) + +Spectrum usage is regulated into FDD and TDD domains. While FDD uses separate frequencies for the uplink and the downlink, TDD uses a single frequency for both uplink and downlink. + +Generally, the unpaired spectrum for TDD is allocated in higher frequencies than FDD. The low-band FDD, due to physical propagation characteristics, offers a wider coverage area than the higher-frequency TDD spectrum. Typically, the low-band FDD is limited in capacity. Mid-band TDD has a higher bandwidth and capacity compared to the low-band FDD. However, mid-band TDD uplink coverage is more limited than the low-band FDD. Spectrum aggregation across FDD and TDD carriers can improve TDD cell coverage and deliver higher throughput than a TDD-only solution. + +Figure 5.3.2.2-1 illustrates a possible way to aggregate the low-band FDD carrier (primary cell) and mid-band TDD carrier (secondary cell). By using the low-band FDD as the primary cell (PCell), the coverage-limiting UL data and control channels of the mid-band TDD carrier can be moved to the low-band FDD. This increases the overall mid-band cell coverage, which means that now the mid-band spectrum can be accessed by more users in the network. By using the mid-band TDD as secondary cell (SCell), the downlink throughput can be significantly improved. This use case provides the unique capability of aggregating low-band FDD and mid-band TDD for higher peak rates and increased cell coverage. + +![Diagram illustrating the aggregation of low-band FDD carrier (PCell) and mid-band TDD carrier (SCell). A large solid oval represents the 'Low-band FDD coverage' area. Inside this oval, a smaller dashed oval represents the 'Mid-band TDD coverage' area. Two antenna icons are shown within the dashed oval, with arrows pointing from them towards the right, indicating the direction of coverage expansion or signal flow.](6d12a8e64a3c8567f52aa3d94dc26716_img.jpg) + +Diagram illustrating the aggregation of low-band FDD carrier (PCell) and mid-band TDD carrier (SCell). A large solid oval represents the 'Low-band FDD coverage' area. Inside this oval, a smaller dashed oval represents the 'Mid-band TDD coverage' area. Two antenna icons are shown within the dashed oval, with arrows pointing from them towards the right, indicating the direction of coverage expansion or signal flow. + +**Figure 5.3.2.2-1: Aggregate low-band FDD carrier (PCell) and mid-band TDD carrier (SCell)** + +#### 5.3.2.3 Maximize the number of CCs being aggregated irrespective of inter or intra-band + +MNO can access multiple carriers across various bands enabled by 5G in low, mid, and high frequencies. National regulators often grant additional spectrum licenses to MNOs in a phased manner. As a result, MNOs can offer services in multiple frequency bands and add spectrum in a phased manner at later dates including low, mid and high-frequency bands. To increase bandwidth and bitrate aggregation, MNOs need to consider spectrum aggregation from same or different vendor's equipment, involving low, mid, and high-band cells with considerations on availability, functionality, cost etc. This enables the use of downlink for all aggregated cells while ensuring connection stability through a common uplink on the lower frequency aggregated carriers. The MNOs primarily benefit from leveraging the cumulative spectrum bandwidth of these allocations from different vendors to achieve higher data rates for end users. + +Figure 5.3.2.3-1 illustrates a scenario where three co-located and overlaid cells are provided by different vendor equipment; a low-band carrier, a mid-band carrier, and a high-band carrier. Maximizing the number of CCs being aggregated can be considered for both NSA and SA scenarios. + +![Figure 5.3.2.3-1: Aggregate multiple cells from different vendor equipment. The diagram shows three concentric ellipses representing different frequency bands. The outermost ellipse is labeled 'Low band cell #1' and contains 'Vendor A' with a radio tower icon. The middle ellipse is labeled 'Mid band cell #2' and contains 'Vendor B' with a radio tower icon. The innermost ellipse is labeled 'High band cell #3' and contains 'Vendor C' with a radio tower icon.](a2bf249fa86d93dbee4354259e850c88_img.jpg) + +Figure 5.3.2.3-1: Aggregate multiple cells from different vendor equipment. The diagram shows three concentric ellipses representing different frequency bands. The outermost ellipse is labeled 'Low band cell #1' and contains 'Vendor A' with a radio tower icon. The middle ellipse is labeled 'Mid band cell #2' and contains 'Vendor B' with a radio tower icon. The innermost ellipse is labeled 'High band cell #3' and contains 'Vendor C' with a radio tower icon. + +**Figure 5.3.2.3-1: Aggregate multiple cells from different vendor equipment** + +#### 5.3.2.4 Spectrum aggregation between low band and mid/high band + +This use case covers the need of spectrum aggregation between low and mid/high band. Let us consider that the MNO has O-DUs/O-RUs operating on low band allocated to the MNO, deployed in the cell site. Later, the regulatory body allocates a new mid/high band spectrum to the same MNO. By supporting aggregation between low and mid/high band cells, the MNO can achieve better coverage for mid/high band and can improve the throughput for UEs connected to low band cells. If existing O-DU with low band is restricted by capacity issue and hence cannot host new cells with mid/high band, a new O-DU may be required to be installed to utilize the newly allocated band. Existing cell may be supporting low band FDD capability while new cells may be supporting high or mid band with TDD duplexing capability. The introduction of new mid/high band cells can reduce the capacity demand of the low band cell as UEs in good coverage conditions can be served by the new cell as shown in Figure 5.3.2.4-1. + +![Figure 5.3.2.4-1: Example of spectrum aggregation between low and mid/high band. The diagram shows a transition from a single cell to two cells. On the left, a grey oval labeled 'Low Band Cell #1 vendor a' has an arrow pointing to the right. On the right, there are two ovals: a light blue one labeled 'Mid/High Band Cell #2 vendor b' and a grey one labeled 'Low Band Cell #1 vendor a'.](a6fb5b9ccab46ca12a23b3d10ed04a2a_img.jpg) + +Figure 5.3.2.4-1: Example of spectrum aggregation between low and mid/high band. The diagram shows a transition from a single cell to two cells. On the left, a grey oval labeled 'Low Band Cell #1 vendor a' has an arrow pointing to the right. On the right, there are two ovals: a light blue one labeled 'Mid/High Band Cell #2 vendor b' and a grey one labeled 'Low Band Cell #1 vendor a'. + +**Figure 5.3.2.4-1: Example of spectrum aggregation between low and mid/high band** + +#### 5.3.2.5 Intra-band spectrum aggregation (contiguous or non-contiguous) + +This use case covers the need of spectrum aggregation between the intra band cells. MNO deploys cells with spectrum allocated from Band B. Later more spectrum from same Band B is allocated to the MNO. Newly allocated spectrum can be contiguous or non-contiguous. The MNO wants to install cells from same or different vendor to support the newly allocated spectrum. As shown in Figure 5.3.2.5-1 below, to enhance the end user throughput by utilizing the newly allocated spectrum, aggregation between the two cells need to be supported. + +![Figure 5.3.2.5-1: Example of spectrum aggregation in intra band contiguous and non-contiguous spectrum. The diagram shows a transition from a single cell to two cells. On the left, an oval labeled 'BAND B, Spectrum X Cell #1, vendor a' has an arrow pointing to the right. On the right, two ovals are stacked: the top one is 'BAND B, Spectrum Y Cell #2, vendor b' and the bottom one is 'BAND B, Spectrum X Cell #1, vendor a'.](2ff760a1f9141fea1f2e0e5372a7517e_img.jpg) + +Figure 5.3.2.5-1: Example of spectrum aggregation in intra band contiguous and non-contiguous spectrum. The diagram shows a transition from a single cell to two cells. On the left, an oval labeled 'BAND B, Spectrum X Cell #1, vendor a' has an arrow pointing to the right. On the right, two ovals are stacked: the top one is 'BAND B, Spectrum Y Cell #2, vendor b' and the bottom one is 'BAND B, Spectrum X Cell #1, vendor a'. + +**Figure 5.3.2.5-1: Example of spectrum aggregation in intra band contiguous and non-contiguous spectrum** + +#### 5.3.2.6 Supplemental Uplink (SUL) use case + +This is a use case to increase the UL coverage and/or capacity by using supplemental uplink (SUL) bands (see 3GPP TS 38.300 [i.4]). The coverage increase of a higher frequency cell is achieved by using the SUL carrier's lower frequency, which has lower path loss than the UL frequency of the higher frequency cell. UEs are typically limited in transmit power compared to gNBs/ng-eNBs. Usage of SUL allows UEs to extend UL coverage by switching the UL frequency to the SUL carrier. Figure 5.3.2.6-1 illustrates this use case. SUL bands are defined in 3GPP TS 38.101-1 [i.5]. The SUL carrier's provisioning and management can be addressed by a different RAN vendor than that of the UL carrier. + +![Figure 5.3.2.6-1: Switching to SUL carrier to increase coverage and/or capacity use case. The diagram shows a gNB/ng-eNB at the center of three concentric ellipses representing coverage areas: the innermost is 'DL coverage', the middle is 'UL coverage', and the outermost is 'SUL coverage'. Below the ellipses is a horizontal axis labeled 'Frequency' with three rectangular blocks: 'SUL' on the left, 'UL' in the middle, and 'DL' on the right, indicating their relative frequency positions.](6f2d68847139b668f7cf85210ec852de_img.jpg) + +Figure 5.3.2.6-1: Switching to SUL carrier to increase coverage and/or capacity use case. The diagram shows a gNB/ng-eNB at the center of three concentric ellipses representing coverage areas: the innermost is 'DL coverage', the middle is 'UL coverage', and the outermost is 'SUL coverage'. Below the ellipses is a horizontal axis labeled 'Frequency' with three rectangular blocks: 'SUL' on the left, 'UL' in the middle, and 'DL' on the right, indicating their relative frequency positions. + +**Figure 5.3.2.6-1: Switching to SUL carrier to increase coverage and/or capacity use case.** + +#### 5.3.2.7 Supplemental Downlink (SDL) use case + +SDL is a spectrum aggregation use case to increase a cell's DL capacity. Aggregating SDL carrier (see 3GPP TS 38.101-1 [i.5]) with any downlink carrier increases the DL bandwidth, thereby increasing the cell's DL capacity. The Figure 5.3.2.7-1 illustrates this spectrum aggregation use case. The aggregation of SDL and DL carriers is as defined in 3GPP TS 38.101-1 [i.5]. The SDL carrier's provisioning and management can be taken care by a different RAN vendor than that of the DL carrier with which the SDL carrier is aggregated. + +![Diagram illustrating the aggregation of SDL with DL carrier for increasing DL capacity use case. A central gNB/ng-eNB is shown with three overlapping coverage areas: DL coverage (downlink), UL coverage (uplink), and SDL coverage (sidelink). A box labeled 'Increase capacity' has arrows pointing to the DL and UL coverage areas. Below the diagram, a horizontal axis labeled 'Frequency' shows three blocks: UL, DL, and SDL, indicating their relative positions in the frequency spectrum.](ce450c78adf312551d6f877c81f38cb1_img.jpg) + +Diagram illustrating the aggregation of SDL with DL carrier for increasing DL capacity use case. A central gNB/ng-eNB is shown with three overlapping coverage areas: DL coverage (downlink), UL coverage (uplink), and SDL coverage (sidelink). A box labeled 'Increase capacity' has arrows pointing to the DL and UL coverage areas. Below the diagram, a horizontal axis labeled 'Frequency' shows three blocks: UL, DL, and SDL, indicating their relative positions in the frequency spectrum. + +**Figure 5.3.2.7-1: Aggregation of SDL with DL carrier for increasing DL capacity use case.** + +### 5.3.3 Synchronization considerations + +Spectrum aggregation often requires deploying multiple nodes to serve a single UE. Such nodes run their own clocks which may or may not be synched with GPS clock. Thus, it cannot be assumed that synchronization required by 3GPP for spectrum aggregation is always possible (as defined in TS 38.133 [i.6], for intra-FR1, maximum received timing difference cannot be bigger than 33 $\mu$ s). While considering techniques for spectrum aggregation, it should be made sure that the requirements for time synchronization between aggregated cells should be as flexible as possible to enable deployments also where the above requirements for time synchronization cannot be achieved. + +### 5.3.4 Network management considerations + +Network management aspects (FCAPS) need to be considered when new spectrum (intra/inter band, contiguous/non-contiguous, FDD/TDD) is added. A few possible scenarios wherein, either a new O-RAN NF needs to be added or existing O-RAN NF continues to support the additional spectrum are listed in Table 5.3.4-1. + +**Table 5.3.4-1: Network management scenarios** + +| Scenario# | O-RU | O-DU | O-CU-CP | O-CU-UP | +|-----------|----------|----------|----------|----------| +| 1 | New | Existing | Existing | Existing | +| 2 | New | New | Existing | Existing | +| 3 | New | New | New | New | +| 4 | Existing | New | Existing | Existing | + +As discussed in previous clauses, network functions (O-RU, O-DU, O-CU-CP, O-CU-UP) can be from one or more vendors with any combination of them. These network functions (NFs) can be managed by EMS/NMS/SMO from one or multiple vendors. Orchestration and automation aspects for multi-vendor scenarios need to be considered as well. This is not addressed in the present document. + +### 5.3.5 RAN intelligence considerations + +RAN intelligence aspects can be considered when new spectrum (intra/inter band, contiguous/non-contiguous, FDD/TDD) is added. Impacts on Near-RT RIC and Non-RT RIC due to the multi-vendor scenarios already listed in clause 5.3.4 can be considered. This is not addressed in the present document. + +### 5.3.6 Considerations for solution evaluation + +When evaluating different solutions and techniques for spectrum aggregation with multi-vendor deployments, the following criteria is proposed: + +- 1) Minimize complexity: Solution complexity in terms of network deployment is an important evaluation criterion. The bandwidth and latency requirements on the underlying transport are to be considered. A multi-vendor interface is designed to be well-defined with clear functional split. +- 2) Minimize impact to inter-operability testing and standardization effort: Efforts needed in the standardization process and inter-operability testing are important criteria in the evaluation of the solutions. In addition, standardizing multiple solution options addressing the same problem is not desirable. +- 3) Increase performance and lower latency: The solution(s) can be evaluated for maximizing utilization of available system capacity (e.g., maximize average and 5th percentile user throughput) and lowering experienced latency to end users. +- 4) Minimize impact on O-RAN architecture: Impact on O-RAN architecture is considered in the evaluation of the solution. There is a benefit in reusing existing interfaces as well as minimizing the impacts to existing O-RAN functions. +- 5) Minimize UE impact: The proposed solution(s) cannot include any changes to the UE specifications or lead to changes to the Uu interface. +- 6) Aligns with 3GPP RAN design: All solutions are to conform to existing 3GPP specifications and cannot introduce any new requirements on 3GPP specifications. +- 7) Increase spectral efficiency of combined carriers: The spectrum aggregation solution(s) are expected to maximize spectral efficiency of combined component carriers. Performance under ideal and non-ideal transport can be assessed. +- 8) Increase coverage and capacity: The spectrum aggregation solution(s) are expected to account for DL and UL path imbalance of high frequency carriers and enable extending the reach of high frequency carrier to as many UEs as possible, e.g., by using UL of a low frequency carrier for UL data traffic while DL data traffic is carried over the higher frequency band, thus increasing coverage and capacity. +- 9) Address security concerns with different solutions: If new interface(s) are defined, the security and integrity of data transfer over the interface are to be protected as specified by O-RAN WG11. The impact of the security requirements on the equipment and the underlying transport needs to be assessed. +- 10) Minimize energy consumption: The preferred solution(s) is the one that minimizes energy consumption while maintaining the required performance (user throughput, enhanced coverage, etc.). All potential solutions can be evaluated for expected energy consumption and performance trade-offs. +- 11) Minimize exchange of scheduling-specific information over open interfaces: The preferred solution is the one that minimizes exchange of the scheduling-related information over open interfaces and thus helps encourage differentiation in particular scheduler implementations. + +# 6 Spectrum aggregation solutions + +## 6.1 Overview + +There are multiple techniques available for multi-vendor spectrum aggregation in 3GPP and O-RAN. These techniques cover different use cases. However, not all the use case defined in clause 5.2.1 are covered due to limitations on existing interfaces. + +Following Spectrum Aggregation techniques are defined in 3GPP Rel-15 for NR [i.4]: + +- 1) Carrier Aggregation (CA) +- 2) Dual Connectivity (DC) + +There are multiple interfaces that can be used to achieve the spectrum aggregation across multi-vendor components using above techniques. These interfaces are defined in 3GPP and O-RAN, and an additional interface is newly proposed below to provide additional functionality for multi-vendor interoperability. + +1. Xn Interface (existing): + - a. Dual connectivity with aggregation at PDCP level, for supporting spectrum aggregation, can be achieved using Xn Interface + - b. Data exchange between primary node and secondary node takes place at PDCP PDU level. +2. F1 Interface (existing): + - a. If multiple O-DUs are connected to the same O-CU-CP/O-CU-UP, F1 interface can be used to provide spectrum aggregation via DC technique. + - b. If an O-DU supports multiple cells, each O-DU node can support CA simultaneously with DC. All the CA links will be within a single vendor O-DU in this case. +3. Open Fronthaul Interface (existing): + - a. CA between cells of different O-RUs connected to a single O-DU can be achieved using O-FH interface. + - b. The O-RUs and the O-DU can be provided by same or different vendors. +4. Inter O-DU Interface (proposal): + - a. CA across cells supported in different vendor O-DUs can be achieved by a potential new interface between O-DUs. + - b. Each O-DU can be connected to different or same vendor O-RUs. The O-DUs can be connected to different or same vendor O-CU-CP/O-CU-UP. + +There are several additional aspects of spectrum aggregation that impact the performance and need to be considered. One such example is the increase in traffic load in O-DUs due to larger bandwidth available to UEs. This can result in an imbalance in the loading of O-DUs that are implementing spectrum aggregation. Therefore, mobility load balancing (MLB) techniques are an important consideration for effective usage of spectrum aggregation. + +The MLB feature is defined in 3GPP TS38.300 specification [i.4]. MLB is achieved by exchanging resource information among gNBs periodically and initiating handover procedure to redirect UE session to other gNBs as shown in Figure 6.1-1. + +![Diagram illustrating Mobility Load balancing between gNBs. It shows two O-CU-CP/UP nodes (O-CU-CP/UP 1 and O-CU-CP/UP 2) connected via X2/Xn interface. Each O-CU-CP/UP node is connected to two O-DU nodes (O-DU 1, O-DU 2 for O-CU-CP/UP 1; O-DU 3, O-DU 4 for O-CU-CP/UP 2) via F1-C/F1-U interface. Arrows indicate Resource Status Report and Handover procedure between O-CU-CP/UP nodes and O-DU nodes.](3ed906d2683ca5d795f98c233c3ab890_img.jpg) + +``` + +graph TD + OCU1[O-CU-CP/UP 1] <-->|X2/Xn| OCU2[O-CU-CP/UP 2] + OCU1 -->|F1-C/F1-U| OD1[O-DU 1] + OCU1 -->|F1-C/F1-U| OD2[O-DU 2] + OCU2 -->|F1-C/F1-U| OD3[O-DU 3] + OCU2 -->|F1-C/F1-U| OD4[O-DU 4] + OD1 -->|Resource Status Report| OCU1 + OD2 -->|Resource Status Report| OCU1 + OD3 -->|Resource Status Report| OCU2 + OD4 -->|Resource Status Report| OCU2 + OCU1 -->|Handover procedure| OD1 + OCU1 -->|Handover procedure| OD2 + OCU2 -->|Handover procedure| OD3 + OCU2 -->|Handover procedure| OD4 + +``` + +Diagram illustrating Mobility Load balancing between gNBs. It shows two O-CU-CP/UP nodes (O-CU-CP/UP 1 and O-CU-CP/UP 2) connected via X2/Xn interface. Each O-CU-CP/UP node is connected to two O-DU nodes (O-DU 1, O-DU 2 for O-CU-CP/UP 1; O-DU 3, O-DU 4 for O-CU-CP/UP 2) via F1-C/F1-U interface. Arrows indicate Resource Status Report and Handover procedure between O-CU-CP/UP nodes and O-DU nodes. + +**Figure 6.1-1: Mobility Load balancing between gNBs.** + +## 6.2 Solution 1: Intra O-DU Carrier Aggregation + +### 6.2.1 Solution description + +#### 6.2.1.1 Intra O-DU multi O-RU carrier aggregation + +In carrier aggregation, spectrum aggregation is achieved at O-DU level. Each O-DU can support multiple cells possibly through multiple O-RUs. The cell where UE is attached is called the Primary Cell (PCell) for that UE while other cells used for carrier aggregation are called Secondary Cells (SCells). + +In DL CA, the primary O-DU receives data from O-CU-UP and schedules the data between the PCell and SCells to transmit to the UE. The UE maintains multiple downlink links as per the number of component carriers (CCs) configured to receive data from gNB. Data received from SCells as well as from PCell is aggregated at MAC level in the UE and forwarded to higher layer. There is a single instance of PDCP, RLC, and other higher layers in the UE, when carrier aggregation is activated. + +In UL CA, SCells and PCell receive UL data (PUSCH) separately from the UE. Data is then aggregated in the PCell and forwarded to the O-CU-UP. The UCI (PUCCH) can be transmitted on the component carriers configured for UL. + +Both SCells and PCell are processed in a single O-DU which is connected with multiple O-RUs using the Open Fronthaul interface. The Open Fronthaul (and F1) interface enables multiple vendor options for an MNO to decide for deployment considerations as shown in Figure 6.2.1-1. Figure 6.2.1-1 shows the intra O-DU DL CA scenario, where the PCell is configured on a carrier served by O-RU1 and DL only SCell(s) are served by O-RUn. In this scenario, PUCCH is carried by the PCell. The UE transmits the PUCCH for PCell PDSCH as well as for SCell PDSCHs on PCell resources. The PUCCH is received by PCell in O-DU. If PUCCH for SCell is present, it is shared with SCells. The O-DU coordinates the sharing of the PUCCH between the PCell and the SCells configured for the UE. + +![Figure 6.2.1-1: Intra O-DU, Multi O-RU DL CA without UL CA. The diagram shows a network architecture with four vendors (a, b, c, d). Vendor a contains O-CU-CP and O-CU-UP. Vendor b contains O-DU. Vendor c contains O-RU1. Vendor d contains O-RUn. A UE is connected to O-RU1 and O-RUn. Data flows: NG to O-CU-CP; O-CU-CP to O-DU via F1-U (dashed); O-DU to O-CU-UP via F1-C (green); O-DU to O-RU1 and O-RUn via Open FH (solid); O-RU1 and O-RUn to UE via Open FH (solid). Signaling (green dashed) goes from O-DU to UE. PUCCH (dotted) goes from UE to O-DU. DL Data (solid black) goes from O-DU to UE. UL Data (dashed black) goes from UE to O-DU.](e3ff0c4aa51f7a73eea2194b96a2d40c_img.jpg) + +Figure 6.2.1-1: Intra O-DU, Multi O-RU DL CA without UL CA. The diagram shows a network architecture with four vendors (a, b, c, d). Vendor a contains O-CU-CP and O-CU-UP. Vendor b contains O-DU. Vendor c contains O-RU1. Vendor d contains O-RUn. A UE is connected to O-RU1 and O-RUn. Data flows: NG to O-CU-CP; O-CU-CP to O-DU via F1-U (dashed); O-DU to O-CU-UP via F1-C (green); O-DU to O-RU1 and O-RUn via Open FH (solid); O-RU1 and O-RUn to UE via Open FH (solid). Signaling (green dashed) goes from O-DU to UE. PUCCH (dotted) goes from UE to O-DU. DL Data (solid black) goes from O-DU to UE. UL Data (dashed black) goes from UE to O-DU. + +**Figure 6.2.1-1: Intra O-DU, Multi O-RU DL CA without UL CA.** + +Intra O-DU CA is implemented within a single O-DU. MLB is taken care of by existing F1/X2/Xn interface by doing intra O-DU handover or inter O-DU handover to other O-DU. + +#### 6.2.1.2 Intra O-DU Shared O-RU carrier aggregation + +Shared O-RU reference architecture is shown in Figure 6.2.1.2-1, where a shared O-RU can share its resources (e.g., carriers) with two O-DUs. The Shared O-RU framework can be used in scenarios when a new O-RU deployment is also + +accompanied by an additional O-DU. Spectrum aggregation across cells supported by an O-DU is then achieved by carrier aggregation. + +![Figure 6.2.1.2-1: Shared O-RU reference diagram. This diagram illustrates a single MNO scenario. At the top is the SMO Host, which contains a common Netconf client. Below it are two O-DU blocks. The left O-DU is labeled 'Shared O-RU Host' and contains a common Netconf client and a carrier-conf Netconf client. The right O-DU is labeled 'Shared Resource Operator' and contains a carrier-conf Netconf client. Both O-DUs are connected to a Shared O-RU block at the bottom, which contains a Netconf server. The connections are as follows: SMO Host to left O-DU (M-Plane OAM config.), left O-DU to SMO Host (O1 interface), left O-DU to Shared O-RU (M-Plane OAM config., M-Plane carrier config., C-Plane section descr.), Shared O-RU to left O-DU (if hybrid topology), left O-DU to Near-RT RIC (O1 interface), Near-RT RIC to left O-DU (O1 interface), left O-DU to O-CU-CP, O-CU-CP to left O-DU, O-DU to SMO Host (O1 interface), SMO Host to right O-DU (O1 interface), right O-DU to Shared O-RU (C-Plane section descr., M-Plane carrier config.), and Shared O-RU to right O-DU (M-Plane carrier config.).](ed0933c87b10f74570e0f6f2b971880b_img.jpg) + +Figure 6.2.1.2-1: Shared O-RU reference diagram. This diagram illustrates a single MNO scenario. At the top is the SMO Host, which contains a common Netconf client. Below it are two O-DU blocks. The left O-DU is labeled 'Shared O-RU Host' and contains a common Netconf client and a carrier-conf Netconf client. The right O-DU is labeled 'Shared Resource Operator' and contains a carrier-conf Netconf client. Both O-DUs are connected to a Shared O-RU block at the bottom, which contains a Netconf server. The connections are as follows: SMO Host to left O-DU (M-Plane OAM config.), left O-DU to SMO Host (O1 interface), left O-DU to Shared O-RU (M-Plane OAM config., M-Plane carrier config., C-Plane section descr.), Shared O-RU to left O-DU (if hybrid topology), left O-DU to Near-RT RIC (O1 interface), Near-RT RIC to left O-DU (O1 interface), left O-DU to O-CU-CP, O-CU-CP to left O-DU, O-DU to SMO Host (O1 interface), SMO Host to right O-DU (O1 interface), right O-DU to Shared O-RU (C-Plane section descr., M-Plane carrier config.), and Shared O-RU to right O-DU (M-Plane carrier config.). + +Figure 6.2.1.2-1: Shared O-RU reference diagram. + +Figure 6.2.1.2-2 shows how shared O-RU can be used in a multi-vendor O-DU/O-RU deployment to enable carrier aggregation of newly deployed spectrum with already deployed carriers. In Figure 6.2.1.2-2 (a), O-RU1, supporting for example carrier 1, is connected to O-DU1. To support new spectrum, O-RUn is added to the network. A new O-DUn can be installed from a different vendor, for example to handle carrier(s) supported by O-RUn if O-DU1 is resource constrained. The new O-DUn can also be connected to the O-RU1. O-RU1 is then configured as shared O-RU and its resources (carriers) are shared between O-DU1 and O-DUn. The UEs connected to O-DUn can use CA for carriers supported by O-RUn and the shared carrier(s) of O-RU1. Even though O-DUn is supported by a different vendor, CA is still achieved among the multiple component carriers within the single vendor O-DUn. In Figure 6.2.1.2-2 (b), a UE connected to O-DU1 cannot be configured for carrier aggregation with carriers(s) from O-RUn. UEs connected to O-DU1 can be configured for carrier aggregation for the carriers supported in O-DU1 (i.e., carriers supported by O-RU1 and carriers supported by other O-RUs, not shown in figure, which are connected to the O-DU1). + +![Figure 6.2.1.2-2: Shared O-RU can be used in multiple O-DU deployments to enable CA. (a) Initial deployment: A UE is connected to O-RU1, which is connected to O-DU1 (vendor a), which is connected to O-CU-UP/O-CU-CP (NG). (b) Addition of new O-DU: A new O-DU2 is added, connected to O-CU-UP/O-CU-CP (NG). O-RU1 is configured as a Shared O-RU, connected to both O-DU1 and O-DU2. O-RU2 is also connected to O-DU2. The UE is connected to O-RU1. The diagram shows the transition from (a) to (b) with the addition of O-DU2 and O-RU2, and the configuration of O-RU1 as a Shared O-RU.](cdaad324ca873164ca37acfde92a7f30_img.jpg) + +Figure 6.2.1.2-2: Shared O-RU can be used in multiple O-DU deployments to enable CA. (a) Initial deployment: A UE is connected to O-RU1, which is connected to O-DU1 (vendor a), which is connected to O-CU-UP/O-CU-CP (NG). (b) Addition of new O-DU: A new O-DU2 is added, connected to O-CU-UP/O-CU-CP (NG). O-RU1 is configured as a Shared O-RU, connected to both O-DU1 and O-DU2. O-RU2 is also connected to O-DU2. The UE is connected to O-RU1. The diagram shows the transition from (a) to (b) with the addition of O-DU2 and O-RU2, and the configuration of O-RU1 as a Shared O-RU. + +Figure 6.2.1.2-2: Shared O-RU can be used in multiple O-DU deployments to enable CA. (a) Initial deployment. (b) Bands supported by O-RU1 and O-RUn can use CA. + +### 6.2.2 Mapping to deployment scenarios and other consideration + +This solution can cover all the deployment scenarios mentioned in clause 5.2.1. Spectrum aggregation when adding the new O-RU to an existing O-DU can be done by intra O-DU carrier aggregation. When a new logical O-DU is also added to an existing deployment (see Figure 5.2.1.2-1(c)), then intra O-DU CA can be realized using the shared O-RU framework as described in clause 6.2.1.2. + +For non-co-located deployment use cases of clause 5.2.2, this solution can cover all scenarios if the fronthaul connecting the O-RU and O-DU has latency within the latency classes of High25, High75 of Table A-1. The High100 and High200 latency classes can also be supported depending on implementation and performance trade-offs. + +3GPP TS 38.101 specification [i.5] defines the various NR band combinations and carrier components that can be used in DC and CA technologies within each frequency range (FR1 or FR2). Table 6.2.2-1 captures the number of NR band combinations supported for various 3GPP releases. + +**Table 6.2.2-1: Band combinations supported across different 3GPP releases.** + +| 3GPP Release | Intra Band | | 2-Band, Inter Band | | 3-Band, Inter Band | | 4-Band, Inter Band | | 5-Band, Inter Band | | SUL | +|-----------------------------------|--------------------------------|----|--------------------|-----|--------------------|-----|--------------------|----|--------------------|----|-----| +| | CA | DC | CA | DC | CA | DC | CA | DC | CA | DC | CA | +| Rel 15 (38.101-1 v15.23.0) | 4 | 0 | 13 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 8 | +| Rel 16 (38.101-1 v16.17.0) | 11 (contig) + 8 (non contig) | 0 | 82 | 1 | 35 | 0 | 6 | 0 | 0 | 0 | 15 | +| Rel 17 (38.101-1 v17.11.0) | 17 (contig.) + 13 (non contig) | 0 | 181 | 120 | 182 | 29 | 75 | 7 | 2 | 0 | 25 | +| Rel 18 (38.101-1 v18.3.0) | 17 (contig) + 14 (non contig) | 0 | 226 | 200 | 272 | 117 | 102 | 29 | 17 | 8 | 32 | + +As shown in Table 6.2.2-1, NR CA has more band combinations compared to NR DC. Release 15 and Release 16 specify NR DC for inter frequency ranges (between FR1 and FR2) but not for bands/frequencies within a given frequency range (FR1 or FR2). For NR spectrum aggregation, Release 15 or Release 16 UEs can use NR DC across FR1 and FR2 but within each frequency range, they can only use CA. Since the UE has to maintain at least two separate uplink connections for DC, the UE power consumption is typically lower in CA (e.g., for DL only CA) where a single UL carrier can be used for all the carriers. + +### 6.2.3 Impact analysis on specifications + +Carrier aggregation for NR is defined in 3GPP specification [i.4]. In Intra O-DU carrier aggregation, the scheduler is residing in the single vendor O-DU and the vendor can implement proprietary algorithms to coordinate DL and UL resources and manage data transfer between PCell and SCells. There is no impact on any specification, as both the cells are running in the same O-DU and O-FH is a well-defined interface in O-RAN for O-DU and O-RU interoperability. + +The shared O-RU approach described in clause 6.2.1.2 uses existing O-FH to connect the existing O-RU with the new O-DU (see Figure 6.2.1.2-2). No new interfaces are needed. However, enhancements to CUS-Plane and M-Plane specifications [i.14], [i.15] might be needed to enable an O-RU to connect with two O-DUs and for the O-RU to share its resources (carriers) dynamically between the two O-DUs for single MNO use case with carrier sharing. This resource partitioning (static or dynamic) use case of sharing carriers is described in clause 4.20.1.2, clause 4.20.2.2 and clause 4.20.3.2 of the O-RAN Use Cases Detailed Specification [i.16]. + +### 6.2.4 Feasibility and gain/complexity analysis + +Table 6.2.4-1 captures the solution evaluation for intra O-DU carrier aggregation covering both multi-O-RU and shared O-RU sub use cases. + +Table 6.2.4-1: Evaluation of intra-O-DU CA + +| Solution Evaluation Criteria | Remarks | +|---------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Minimize complexity | No impact. Open FH is already a standard solution in O-RAN. | +| Minimize impact to inter-operability testing and standardization effort | No impact. Already a standardized interface. | +| Increase performance and lower latency | Since spectrum aggregation is done at O-DU level, latency will be very low. Performance of spectrum aggregation is also better compared to DC. | +| Minimize impact on O-RAN architecture | No impact. Open FH is a standardized interface. | +| Minimize UE impact | No impact. | +| Aligns with 3GPP RAN design | Aligned (Open FH is not defined in 3GPP but is aligned with the 3GPP standards for CA). | +| Increase spectral efficiency of combined carriers | Maximum possible for spectrum aggregation techniques and allowed combinations. | +| Increase coverage and capacity | Maximum for any spectrum aggregation technique [i.7]. | +| Address security concerns with different solutions | No impact. Already a standardized solution. | +| Minimize energy consumption | In DL CA, single PUCCH on PCell can carry the HARQ feedback or CQI etc for all the carriers while in DC, it is different PUCCH for both the carriers. Hence, energy consumption by UE will be lesser in CA compared to DC [i.8]. | +| Minimize exchange of scheduling-specific information over open interfaces | No impact. Monitoring of the Open FH does not offer information about MAC implementation. Monitoring of multiple Open FH does not change this situation. | + +## 6.3 Solution 2: Inter O-DU Carrier Aggregation + +### 6.3.1 Solution description + +In case the product/server realizing the O-DU is not capable of being upgraded to support new band or capability either because of software or hardware limitations, carrier aggregation still can be achieved by installing a new O-DU with the required capability or to increase the capacity. Newly installed O-DU can be provided by the same vendor or different vendors. For supporting CA, O-DUs can be connected with a newly proposed O-RAN interface inter-connecting the two MAC layers. Details on how this solution can potentially be implemented is described below. + +For supporting carrier aggregation across multi-vendor O-DUs which are running in different servers, existing interfaces Xn (at O-CU-CP/O-CU-UP level), F1 (between O-CU-CP/O-CU-UP and O-DU) and Open Fronthaul (between O-DU and multiple O-RU) cannot be used as none of the interfaces support connection between O-DUs. Hence, support for newly proposed interface between O-DUs is required in this scenario. If existing O-DUs already support the interface or it can be supported by a software upgrade, carrier aggregation across O-DUs can be achieved. By supporting an inter O-DU interface for CA, MNO can benefit from all the benefits of spectrum aggregation through CA. + +A Service Management & Orchestrator (SMO) configures O-DUs using O1 interface as shown in Figure 6.3.1-1. O-DUs and O-RUs need to be compatible from Management plane perspective. This is the requirement for interworking of newly installed O-DU with existing/new O-RU irrespective of inter O-DU CA. The O1 interface can be updated to bring additional information such as IP address of the O-DUs, C-RNTIs, or PCIs, that is needed for the functioning of inter O-DU interface. The inter O-DU interface can also be configured automatically based on self-detection of O-DUs supporting cells that can be aggregated. + +![Figure 6.3.1-1: O-DU configuration by SMO (modified from [i.17] to show the new interface).](22353a834c1d92284324500cb212ae1e_img.jpg) + +This diagram illustrates the O-DU configuration by the Service Management and Orchestration Framework (SMO). The SMO is represented by a purple box at the top, containing a green box labeled 'Non-Real Time RIC'. The SMO connects to various network elements via interfaces: O1 (to O-CU-UP and O-CU-CP), O2 (to O-CU-UP), and O3 (to O-DU). The O-CU-UP and O-CU-CP are shown as orange boxes, connected via E1 and Xn-c interfaces. The O-DU is shown as a red box, connected via F1-c and F1-u interfaces. The O-DU is further connected to O-RU (red box) and O-Cloud (green box) via Open FH CUS-Plane and Open FH M-Plane interfaces. A legend on the right identifies the interfaces: 3GPP interfaces (black), O-RAN interfaces (green), and New Proposed O-RAN Interface (red dashed line). + +Figure 6.3.1-1: O-DU configuration by SMO (modified from [i.17] to show the new interface). + +**Figure 6.3.1-1: O-DU configuration by SMO (modified from [i.17] to show the new interface).** + +In Figure 6.3.1-2 O-DU1 is hosting primary cells while O-DU2... O-DUn are hosting SCells. The dotted colored interface is indicating the DL CA across O-DUs using the new interface (D2-C and D2-U). O-DU1 receives data from O-CU-UP and schedules DL Data with O-DU2 ... O-DUn to transmit on SCells. If there is no UL CA supported, PUCCH for SCells and PCells shall be received by O-DU1 as shown in Figure 6.3.1-2. O-DU1 shall extract the relevant part of the PUCCH information such as CQI, HARQ feedback and forward it to SCells. + +NOTE: 'n' is not equal to maximum number of aggregated component carriers, rather the maximum number of inter-connected O-DUs for a given deployment that are used for CA across relevant SCells. + +![Figure 6.3.1-2: Inter O-DU DL Carrier Aggregation without UL CA.](a4fda10a8f2a7ed99774f33136b228c6_img.jpg) + +This diagram illustrates Inter O-DU DL Carrier Aggregation without UL CA. It shows three O-CU-CP/O-CU-UP blocks (O-CU-CP1/O-CU-UP1, O-CU-CP2/O-CU-UP2, and O-CU-CPn/O-CU-UPn) connected to three O-DU blocks (O-DU1, O-DU2, and O-DUn). The O-DU blocks are connected to three O-RU blocks (O-RU1, O-RU2, and O-RUn). The O-DU1 block is connected to O-RU1, O-RU2, and O-RUn via Open FH interfaces. The O-DU2 block is connected to O-RU2 and O-RUn via Open FH interfaces. The O-DUn block is connected to O-RUn via Open FH interfaces. The O-DU1 block is connected to O-DU2 and O-DUn via D2-U and D2-C interfaces. The O-DU2 block is connected to O-DUn via D2-U and D2-C interfaces. The O-DU1 block is connected to O-RU1 via F1-U and F1-C interfaces. The O-DU2 block is connected to O-RU2 via F1-U and F1-C interfaces. The O-DUn block is connected to O-RUn via F1-U and F1-C interfaces. A legend on the right identifies the interfaces: Signaling (green), DL Data (black), PUCCH (dotted black), D2-U (blue dashed), and D2-C (orange dashed). + +Figure 6.3.1-2: Inter O-DU DL Carrier Aggregation without UL CA. + +**Figure 6.3.1-2: Inter O-DU DL Carrier Aggregation without UL CA.** + +At power up, each O-DU connects to its peer O-DUs based on the configuration received via O1 interface. SCells from peer O-DUs can be added only if link establishment between the O-DUs is successful. Once a O-DU triggers the link establishment request towards another O-DU, it may accept or reject the request. If the request is rejected, pair of O-DUs can not be used for CA. On SCell addition from O-CU-CP, primary O-DU shares the SCell information such as CRNTI, Cell ID of SCell, QoS, RLC configuration etc with secondary O-DUs supporting SCells. After successful addition of SCells from other O-DUs, SCells can be activated for the UE. At SCell activation, the primary O-DU, informs secondary O-DUs about CA activation so that data exchange can take place. + +If UL CA is also enabled along-with DL CA, UE maintains multiple links for uplink data. UE transmits data on the respective SCells, which can belong to different O-DUs, depending on the scheduling of PUSCH in SCells. Data is then transferred from secondary O-DUs to the primary O-DU for aggregation. The primary O-DU sends the aggregated data to O-CU-UP. In this case UCI for both PCell and SCell can also come multiplexed with PUSCH data on SCell depending on scheduling in the SCell. + +As showing in Figure 6.3.1-3 & Figure 6.3.1-4, UE is connected to PCell running in the O-DU1 while SCells are running in the O-DU2 and the O-DUn. UE transmits the data on the cell(s) as scheduled by the PDCCH. SCell(s) receive PUSCH containing user data and control (UCI) information. Secondary O-DU (O-DUn) then forwards the user data and UCI information (for example HARQ feedback, CQI) for PCell and SCells to the Primary O-DU (O-DU1). Primary O-DU shares the UCI information with other secondary O-DUs (O-DU2). In Figure 6.3.1-3, UCI bits are scheduled on the primary O-DU (O-DU1). O-DU1 receives UCI information related to SCells. O-DU1 then parses and sends UCI information to O-DU2 and O-DUn if present. In Figure 6.3.1-4, UCI is scheduled on secondary O-DUn multiplexed with PUSCH. The O-DUn receives the UL data along with the UCI information and shares UL Data and UCI information with the O-DU1. The O-DU1 forwards UCI information to secondary O-DU2, if present. + +![Figure 6.3.1-3: Inter O-DU UL CA, PUCCH on PCell. This diagram illustrates the network architecture for uplink carrier aggregation (UL CA) with PUCCH on the Primary Cell (PCell). A User Equipment (UE) is connected to three radio units: O-RU1, O-RU2, and O-RUn. O-RU1 is connected to O-DU1, O-RU2 to O-DU2, and O-RUn to O-DUn. O-DU1 is the primary O-DU, while O-DU2 and O-DUn are secondary O-DUs. O-DU1 is connected to O-CU-CP1/O-CU-UP1, and O-DUn is connected to O-CU-CP2/O-CU-UP2. The diagram shows the flow of signaling (green solid arrows), UL data (black solid arrows), PUCCH (black dashed arrows), D2-U (blue dashed arrows), and D2-C (orange dashed arrows). Signaling flows from NG to O-CU-CP1/O-CU-UP1 and O-CU-CP2/O-CU-UP2. UL data flows from UE to O-RU1, O-RU2, and O-RUn, then to O-DU1, O-DU2, and O-DUn respectively. PUCCH flows from UE to O-RU1, then to O-DU1. D2-U flows from O-DU2 and O-DUn to O-DU1. D2-C flows from O-DU2 and O-DUn to O-DU1. Open FH (Open Frequency Handoff) is indicated between O-DU1 and O-DU2, and between O-DU1 and O-DUn.](e082d7745219ae62560019b9cd4375c6_img.jpg) + +Figure 6.3.1-3: Inter O-DU UL CA, PUCCH on PCell. This diagram illustrates the network architecture for uplink carrier aggregation (UL CA) with PUCCH on the Primary Cell (PCell). A User Equipment (UE) is connected to three radio units: O-RU1, O-RU2, and O-RUn. O-RU1 is connected to O-DU1, O-RU2 to O-DU2, and O-RUn to O-DUn. O-DU1 is the primary O-DU, while O-DU2 and O-DUn are secondary O-DUs. O-DU1 is connected to O-CU-CP1/O-CU-UP1, and O-DUn is connected to O-CU-CP2/O-CU-UP2. The diagram shows the flow of signaling (green solid arrows), UL data (black solid arrows), PUCCH (black dashed arrows), D2-U (blue dashed arrows), and D2-C (orange dashed arrows). Signaling flows from NG to O-CU-CP1/O-CU-UP1 and O-CU-CP2/O-CU-UP2. UL data flows from UE to O-RU1, O-RU2, and O-RUn, then to O-DU1, O-DU2, and O-DUn respectively. PUCCH flows from UE to O-RU1, then to O-DU1. D2-U flows from O-DU2 and O-DUn to O-DU1. D2-C flows from O-DU2 and O-DUn to O-DU1. Open FH (Open Frequency Handoff) is indicated between O-DU1 and O-DU2, and between O-DU1 and O-DUn. + +Figure 6.3.1-3: Inter O-DU UL CA, PUCCH on PCell. + +![Figure 6.3.1-4: Inter O-DU UL CA, PUCCH on SCell. This diagram illustrates the network architecture for uplink carrier aggregation (UL CA) with PUCCH on the Secondary Cell (SCell). A User Equipment (UE) is connected to three radio units: O-RU1, O-RU2, and O-RUn. O-RU1 is connected to O-DU1, O-RU2 to O-DU2, and O-RUn to O-DUn. O-DU1 is the primary O-DU, while O-DU2 and O-DUn are secondary O-DUs. O-DU1 is connected to O-CU-CP1/O-CU-UP1, and O-DUn is connected to O-CU-CP2/O-CU-UP2. The diagram shows the flow of signaling (green solid arrows), UL data (black solid arrows), PUCCH (black dashed arrows), D2-U (blue dashed arrows), and D2-C (orange dashed arrows). Signaling flows from NG to O-CU-CP1/O-CU-UP1 and O-CU-CP2/O-CU-UP2. UL data flows from UE to O-RU1, O-RU2, and O-RUn, then to O-DU1, O-DU2, and O-DUn respectively. PUCCH flows from UE to O-RU2, then to O-DU2. D2-U flows from O-DU2 and O-DUn to O-DU1. D2-C flows from O-DU2 and O-DUn to O-DU1. Open FH (Open Frequency Handoff) is indicated between O-DU1 and O-DU2, and between O-DU1 and O-DUn.](2406a74c5810c8e0511740583fcce9fe_img.jpg) + +Figure 6.3.1-4: Inter O-DU UL CA, PUCCH on SCell. This diagram illustrates the network architecture for uplink carrier aggregation (UL CA) with PUCCH on the Secondary Cell (SCell). A User Equipment (UE) is connected to three radio units: O-RU1, O-RU2, and O-RUn. O-RU1 is connected to O-DU1, O-RU2 to O-DU2, and O-RUn to O-DUn. O-DU1 is the primary O-DU, while O-DU2 and O-DUn are secondary O-DUs. O-DU1 is connected to O-CU-CP1/O-CU-UP1, and O-DUn is connected to O-CU-CP2/O-CU-UP2. The diagram shows the flow of signaling (green solid arrows), UL data (black solid arrows), PUCCH (black dashed arrows), D2-U (blue dashed arrows), and D2-C (orange dashed arrows). Signaling flows from NG to O-CU-CP1/O-CU-UP1 and O-CU-CP2/O-CU-UP2. UL data flows from UE to O-RU1, O-RU2, and O-RUn, then to O-DU1, O-DU2, and O-DUn respectively. PUCCH flows from UE to O-RU2, then to O-DU2. D2-U flows from O-DU2 and O-DUn to O-DU1. D2-C flows from O-DU2 and O-DUn to O-DU1. Open FH (Open Frequency Handoff) is indicated between O-DU1 and O-DU2, and between O-DU1 and O-DUn. + +Figure 6.3.1-4: Inter O-DU UL CA, PUCCH on SCell. + +In the case of intra gNB, inter O-DU CA, MLB can be achieved through F1 interface. For MLB, one or more UEs can be handed over to other O-DUs. Handover can be done to both co-located and non-co-located O-DUs. Inter O-DU handover using F1 interface is defined in 3GPP specifications. Additionally, the new interface between O-DUs, if defined, also can be used to share the resource status information between the O-DUs so that the PCell can avoid activating SCells on the O-DU facing loading condition as shown in Figure 6.3.1-5 below. + +![Figure 6.3.1-5: Mobility load balancing with intra gNB, inter O-DUs CA. The diagram shows a central O-CU-CP/UP 1 block at the top. Below it are two O-DU blocks, O-DU 1 and O-DU 2. O-DU 1 is connected to O-CU-CP/UP 1 via a bidirectional arrow labeled 'F1-C/ F1-U'. O-DU 2 is also connected to O-CU-CP/UP 1 via a bidirectional arrow labeled 'F1-C/ F1-U'. A dashed arrow labeled 'Resource Status Report' points from O-DU 1 to O-DU 2. A solid blue arrow labeled 'New IF' points from O-DU 1 to O-DU 2. Text labels 'Resource Status Report' and 'Handover procedure' are placed near the F1-C/F1-U arrows.](ad72dbfc1a166edf763ed5eeaaf46e01_img.jpg) + +Figure 6.3.1-5: Mobility load balancing with intra gNB, inter O-DUs CA. The diagram shows a central O-CU-CP/UP 1 block at the top. Below it are two O-DU blocks, O-DU 1 and O-DU 2. O-DU 1 is connected to O-CU-CP/UP 1 via a bidirectional arrow labeled 'F1-C/ F1-U'. O-DU 2 is also connected to O-CU-CP/UP 1 via a bidirectional arrow labeled 'F1-C/ F1-U'. A dashed arrow labeled 'Resource Status Report' points from O-DU 1 to O-DU 2. A solid blue arrow labeled 'New IF' points from O-DU 1 to O-DU 2. Text labels 'Resource Status Report' and 'Handover procedure' are placed near the F1-C/F1-U arrows. + +**Figure 6.3.1-5: Mobility load balancing with intra gNB, inter O-DUs CA.** + +In the case of inter gNB, inter O-DU CA, MLB can be achieved via F1 and X2/Xn interface [i.12] [i.13]. On a condition triggering MLB, one or more UEs can be handed over to other O-DU. On detecting any MLB condition, O-DU can inform O-CU-CP about the resource status on F1 interface. Based on these reports, O-CU-CP can trigger X2/Xn handover towards another O-DU. All these procedures are defined in 3GPP specifications. Additionally, if secondary O-DU is loaded, interface between O-DUs can be used to report the resource condition to primary O-DU as shown in Figure 6.3.1-6 below. Primary O-DU can avoid SCell activation towards this O-DU to avoid loading with exchanging resource information such as “Radio Resource Status” IE defined in 3GPP TS 38.423 [i.13]. + +![Figure 6.3.1-6: Mobility load balancing with inter gNB, inter O-DUs CA. The diagram shows two O-CU-CP/UP blocks, O-CU-CP/UP 1 and O-CU-CP/UP 2, at the top. Below them are two O-DU blocks, O-DU 1 and O-DU 2. O-DU 1 is connected to O-CU-CP/UP 1 via a bidirectional arrow labeled 'F1-C/ F1-U'. O-DU 2 is connected to O-CU-CP/UP 2 via a bidirectional arrow labeled 'F1-C/ F1-U'. A dashed arrow labeled 'Resource Status Report' points from O-DU 1 to O-DU 2. A solid blue arrow labeled 'New IF' points from O-DU 1 to O-DU 2. A dashed arrow labeled 'X2/Xn' points from O-CU-CP/UP 1 to O-CU-CP/UP 2. Text labels 'Resource Status Report' and 'Handover procedure' are placed near the F1-C/F1-U arrows.](d897adb34077ec171cdca43660553816_img.jpg) + +Figure 6.3.1-6: Mobility load balancing with inter gNB, inter O-DUs CA. The diagram shows two O-CU-CP/UP blocks, O-CU-CP/UP 1 and O-CU-CP/UP 2, at the top. Below them are two O-DU blocks, O-DU 1 and O-DU 2. O-DU 1 is connected to O-CU-CP/UP 1 via a bidirectional arrow labeled 'F1-C/ F1-U'. O-DU 2 is connected to O-CU-CP/UP 2 via a bidirectional arrow labeled 'F1-C/ F1-U'. A dashed arrow labeled 'Resource Status Report' points from O-DU 1 to O-DU 2. A solid blue arrow labeled 'New IF' points from O-DU 1 to O-DU 2. A dashed arrow labeled 'X2/Xn' points from O-CU-CP/UP 1 to O-CU-CP/UP 2. Text labels 'Resource Status Report' and 'Handover procedure' are placed near the F1-C/F1-U arrows. + +**Figure 6.3.1-6: Mobility load balancing with inter gNB, inter O-DUs CA.** + +Figure 6.3.1-7 shows the protocol stack for inter O-DU CA between two O-DUs. The RLC layer hosted in primary O-DU is common for both primary and secondary O-DU for a particular UE while MAC layer can be present in both primary and secondary O-DUs for a UE. + +![Figure 6.3.1-7: Protocol stack in O-DUs for Inter O-DU CA. The diagram shows two O-DUs: Primary O-DU (PCell) and Secondary O-DU (SCell). The Primary O-DU stack includes F1-C Mgr/D2-C Mgr, RLC, MAC, and PHY. The Secondary O-DU stack includes F1-C Mgr/D2-C Mgr, MAC, and PHY. The NG interface connects to the O-CU-CP/O-CU-UP block. F1-C and F1-U interfaces connect the O-CU-CP/O-CU-UP to the F1-C Mgr/D2-C Mgr in the Primary O-DU. A dashed orange line represents the Control Plane (D2-C) between the F1-C Mgr/D2-C Mgr of both O-DUs. A solid blue line represents the User Plane (D2-U) between the MAC of both O-DUs.](0af83e0dfa496cc337d2e037f9dab2e5_img.jpg) + +Figure 6.3.1-7: Protocol stack in O-DUs for Inter O-DU CA. The diagram shows two O-DUs: Primary O-DU (PCell) and Secondary O-DU (SCell). The Primary O-DU stack includes F1-C Mgr/D2-C Mgr, RLC, MAC, and PHY. The Secondary O-DU stack includes F1-C Mgr/D2-C Mgr, MAC, and PHY. The NG interface connects to the O-CU-CP/O-CU-UP block. F1-C and F1-U interfaces connect the O-CU-CP/O-CU-UP to the F1-C Mgr/D2-C Mgr in the Primary O-DU. A dashed orange line represents the Control Plane (D2-C) between the F1-C Mgr/D2-C Mgr of both O-DUs. A solid blue line represents the User Plane (D2-U) between the MAC of both O-DUs. + +**Figure 6.3.1-7: Protocol stack in O-DUs for Inter O-DU CA.** + +There are two parts of the inter O-DU interface referred to as D2 here. + +- D2-C: Exchange of Control information. SCTP can be used as transport protocol. +- D2-U: Exchange of user data and PUCCH information. GTP-U is used for transport mechanisms. + +#### D2 Control Interface (D2-C): + +D2-C functionality involves the establishment and management of the link between O-DUs. SCTP is used as transport protocol. Link establishment between O-DUs takes place before any UE is connected to the O-DU. Main functionality of D2-C includes: + +- Establish connection between O-DUs. +- Connection establishment can happen as soon as the O-DU comes up. +- SCell Addition/Deletion/Modification. It can be triggered on SCell addition/deletion/modification for a particular UE. + +Figure 6.3.1-8 indicates the sample message sequence for D2 link establishment. Figure 6.3.1-8 indicates the procedure and not the actual interface name or parameters. + +![Figure 6.3.1-8: D2 link establishment. The diagram shows the Primary O-DU and Secondary O-DUs connected via a Proposed D2 interface. The Primary O-DU sends a Setup Request (D2-C) to the Secondary O-DUs, which then sends a Setup Response (D2-C) back. The O-CU-CP/O-CU-UP is connected to the Secondary O-DUs via the F1 interface. A box on the right lists considerations during setup: Latency Requirement, C-RNTI collision avoidance, Served Cell information, cell list, band information, duplex type etc.](47ae93a1126ff13744b876f0997fbf03_img.jpg) + +Figure 6.3.1-8: D2 link establishment. The diagram shows the Primary O-DU and Secondary O-DUs connected via a Proposed D2 interface. The Primary O-DU sends a Setup Request (D2-C) to the Secondary O-DUs, which then sends a Setup Response (D2-C) back. The O-CU-CP/O-CU-UP is connected to the Secondary O-DUs via the F1 interface. A box on the right lists considerations during setup: Latency Requirement, C-RNTI collision avoidance, Served Cell information, cell list, band information, duplex type etc. + +**Figure 6.3.1-8: D2 link establishment.** + +#### D2 User Interface (D2-U): + +The D2-U part of the interface is responsible for user data and PUCCH/UCI information exchange between O-DUs. GTP-U is used as the transport protocol for this interface. Main functionality of D2-U includes: + +- Data exchange between primary and secondary O-DU. +- For DL-CA, primary O-DU receives data from O-CU-UP. The PDCCH is scheduled on both the O-DUs independently, similar to Intra O-DU CA case. +- For DL CA, PUCCH resource allocation is done by primary O-DU. PUCCH related information (e.g. PUCCH Resource Indicator etc), required to be encoded in PDCCH, is shared between the primary and secondary O-DUs. UCI information on PUCCH for all the O-DUs is received by primary O-DU. It then forwards the information related to an SCell to the respective secondary O-DU. +- For UL CA, both PCell on primary O-DU and SCells on secondary O-DUs receive data from UE. After MAC layer processing, secondary O-DU sends UE UL data to the primary O-DU, which then forwards it to the RLC layer residing in the primary O-DU. + +Figure 6.3.1-9 indicates the information exchange on D2-U interface. + +![Sequence diagram showing D2-U usage between Primary O-DU and Secondary O-DUs. The diagram illustrates three types of New I/F Messages: [PUCCH, PDCCH Resource Allocation], [DL Buffer Information], and [DL Data]. All messages are sent from Primary O-DU to Secondary O-DUs. A 'NEW' label is above the connection line.](c8a977d414f17a853d76c662eb53e281_img.jpg) + +``` + +sequenceDiagram + participant Primary as Primary O-DU + participant Secondary as Secondary O-DUs + Note over Primary, Secondary: NEW + Primary->>Secondary: [MAC Layer information exchanges] + Primary->>Secondary: [PUCCH, PDCCH Resource Allocation] + Primary->>Secondary: [DL Buffer Information] + Primary->>Secondary: [DL Data] + +``` + +Sequence diagram showing D2-U usage between Primary O-DU and Secondary O-DUs. The diagram illustrates three types of New I/F Messages: [PUCCH, PDCCH Resource Allocation], [DL Buffer Information], and [DL Data]. All messages are sent from Primary O-DU to Secondary O-DUs. A 'NEW' label is above the connection line. + +**Figure 6.3.1-9: D2-U usage.** + +For D2 interface configuration and management, existing O1 interface that brings O-DU configuration from SMO can be enhanced. The D2 interface can be defined in a manner similar to the 3GPP defined F1 interface: a control part D2-C to carry control related information and a user plane part D2-U carrying user data as described above. Existing security mechanism defined in WG11 e.g., IPSec or any other mechanism can be utilized for protecting D2 interface as well. Brief outlines of control and data plane procedures expected from D2 interface are also described in Figure 6.3.1-8 and Figure 6.3.1-9. An example of protocol stack split for supporting inter O-DU CA is also captured in Annex B. + +As the interface between the O-DUs is kept at MAC sub-layer for user plane, this tends to reduce the bandwidth requirement. Bandwidth requirements for inter O-DU CA can be the same or lower than F1 bandwidth requirement. The D2 interface can be designed to accommodate the latency class High75, High100 & High200 as described in Table A-1. The total round trip transmission and processing delay is bounded by 500 $\mu$ s. Coverage of mid/high band carrier can be improved if inter O-DU CA is supported between O-DUs with PCell on low band FDD carrier and SCell on mid/high band TDD carrier. This coverage improvement, due to PUCCH for mid/high band SCells being received on low band PCell, can be similar to the intra O-DU CA solution. + +### 6.3.2 Mapping to deployment scenarios and other consideration + +This solution can cover all the deployment scenarios mentioned in clause 5.2.1.2 and clause 5.2.2 if the latency requirement between O-DUs is maintained as mentioned in clause 6.3.1. Spectrum aggregation across multiple multi-vendor O-DUs, either in co-located or non-co-located scenarios, can be achieved with this solution. Band combinations for NR CA are defined in Table 6.2.2-1 in clause 6.2.2. Energy consumption at UE is similar to intra O-DU CA solution + +as defined in clause 6.2.2, but at the network side, energy consumption can be higher due to message exchange between O-DUs. SDL bands are low bands that can be used to increase the coverage and throughput. If an SDL band is allocated to the MNO and it is supported in a different O-DU, it can be used for CA using this interface. On allocation of SUL band, if support of the SUL band cannot be extended in existing O-DU(s), another O-DU supporting SUL carrier can be used to provide the switching between the carriers for better coverage and performance. The proposed interface can be used to support this switching. + +### 6.3.3 Impact analysis on specifications + +There is no direct standardized inter O-DU interface defined in existing 3GPP or O-RAN specifications. For supporting inter O-DU carrier aggregation, a new inter O-DU interface needs to be defined. For supporting multi-vendor inter O-DU CA, the following Table 6.3.3-1 captures all the WGs that will be impacted for supporting multi-vendor inter O-DU CA. Impact on each WG is also mentioned in the table. + +**Table 6.3.3-1: WGs and specifications impact of standardization of inter O-DU interface.** + +| # | WGs | Specifications | Objective description | +|---|------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | WG1 (UCTG) | O-RAN.WG1.Use-Cases-Detailed-Specification | UCTG specification for existing use cases such as Shared O-RU, traffic steering may need some updates. | +| 2 | WG1 (ATG) | O-RAN.WG1.O-RAN-Architecture-Description | Existing architecture document need to be updated to capture the newly proposed interface between O-DUs. | +| 3 | WG5 | O-RAN Interoperability Test Specification (IOT)

New Specification:
O-RAN.WG5.O-DU-D2 Interface-Specification | New interface needs to be defined between O-DUs for supporting inter O-DU CA.

D2 Interface document will capture C Plane, U plane details as well synchronization requirement.

Heartbeat management can be taken care of by D2 Interface. | +| 4 | WG10 | WG10 O-RAN O1 Interface Specification

WG10 O-RAN O1 Network Resource Model Specification

WG10 O-RAN O1 Performance Measurements Specification | O1 interface and IM/DM documents can be updated to support configuration of the O-DUs with peer O-DUs information for supporting multi-vendor inter O-DU CA.

Existing yang model can be enhanced to bring in information such as IP address of peer O-DUs, RNTIs, PCI. Faults KPI can also be updated in O1 interface documents. | +| 5 | WG11 | O-RAN.WG11.Security-Requirements-Specification

O-RAN Security Test Specifications | Security documents can be reviewed and updated to support the new interface between O-DUs. It can be considered as interface security. | + +### 6.3.4 Feasibility and gain/complexity analysis + +Table 6.3.4-1 evaluates the Inter O-DU solution against the solution evaluation criteria listed in clause 5.3. + +**Table 6.3.4-1: Evaluation of Inter O-DU CA.** + +| Solution Evaluation Criteria | Comment | +|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Minimize complexity | A new interface connecting multiple O-DUs needs to be defined for supporting spectrum aggregation. This requires defining a management interface for tasks such as to establish and maintain O-DU relations, and SCell associations. A new signaling protocol, for example, to add/remove UE context, transfer user plane data and data flow management is also needed. Time synchronization across O-DUs also need to be specified. Clause 6.3.1 covers more details on complexity. The bandwidth and latency requirements and their impact on performance of carrier aggregation also needs to be evaluated in detail at WI phase. Clause 6.3.1 covers more details on bandwidth and latency requirement. | + +| Solution Evaluation Criteria | Comment | +|---------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Minimize impact to Inter-operability testing and standardization effort | A new interface requires additional inter-operability testing requirements. Standardization effort requires involving multiple WGs in O-RAN such as WG1, WG5, WG10, and WG11. In addition, other groups such as WG3 or WG6 may be involved to enable additional functionality. | +| Increase performance and lower latency | Performance will not only depend on the details of the signaling protocol designed for the new interface but also on the scheduling and flow control policies of the aggregated SCells residing in different DUs. Flow misconfiguration can adversely impact overall cell throughput. The underlying transport latency amongst different O-DUs can impact CA performance compared with single O-DU solution. In general, intra O-DU CA is expected to have superior performance in terms of user and cell throughput when compared with an inter O-DU solution. Therefore, the choice of interface termination points and solution design should take this into consideration while exploring the potential solutions.
Faster activation of CA helps in achieving better performance in bursty UL traffic scenarios, though transport delay between O-DUs may impact it. | +| Minimize impact on O-RAN architecture | A new interface needs to be defined in the O-RAN architecture between O-DUs and requires modification to the existing architecture. The impact on O-RAN depends on the solutions proposed for this new interface and detailed specification would be done in WI. Initial impact on O-RAN architecture is covered in clause 6.3.1.
O1 interface need to be enhanced to support D2 interface configuration and LCM. | +| Minimize UE impact | No impact. The solution is assumed to be transparent for the UE. | +| Aligns with 3GPP RAN design | From the UE perspective, the solution is transparent and thus aligned with 3GPP CA architecture. However, to support new interface, MNOs would need to update their O-DU software and/or hardware, depending on their current implementations to enable multi-vendor carrier aggregation. To support inter O-DU CA in beyond 5G, some changes might be required depending on the architecture of beyond 5G that need to be considered at the new RAN design. | +| Increase spectral efficiency of combined carriers | CA provides best spectral efficiency among known spectrum aggregation techniques. However, proper design choices need to be made for the protocol split and interface termination points as different flow management and scheduling policies of disjoint schedulers can adversely impact performance. | +| Increase coverage and capacity | CA provides best coverage and capacity among known spectrum aggregation techniques [i.7]. However, proper design choices need to be made for the protocol split and interface termination points in order to obtain best coverage and capacity for multi-vendor carrier aggregation. | +| Address security concerns with different solutions | The new interface needs a security analysis to be performed by WG11 to ensure the interface has appropriate protections for confidentiality, integrity, availability, authentication, and authorization. This process typically takes one release train and may result in normative requirements specified for the subsequent release train. Analysis and recommended normative security requirements need to be shared with all WGs that are stakeholders for the new interface specification | +| Minimize energy consumption | For DL CA, a single PUCCH on PCell carries the HARQ feedback/CQI etc for all the aggregated carriers while in DC each cell group has a separate carrier for UCI and hence energy consumption by UE will be lower in CA compared to DC [i.8]. From a network perspective, the interface between two or more separate O-DUs can slightly elevate overall network power consumption compared to a single O-DU CA; moreover, in certain deployments like vRANs, the flexibility and scalability offered by a multi-vendor inter-DU interface for CA should also be taken into account in the overall considerations on network energy consumption. | +| Minimize exchange of scheduling-specific information over open interfaces | The new interface should be defined in such a way that scheduling specific information exchange is minimized between the nodes. The information exchange depends on the details of the interface. Depending on the design, the new interface could resemble O-FH and offer limited opportunity for obtaining scheduling information of the primary O-DU. Alternatively, it may require flow control between the schedulers of involved O-DUs; this flow control mechanism may be more detailed as compared to the flow control used for DC due to higher performance requirements of CA. | + +| Solution Evaluation Criteria | Comment | +|------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |

The mechanism will have to be general enough to handle various schedulers, but this generality may handicap efficiency of the solution (as compared to intra O-DU CA).

Proposed solution for the D2 interface is described in clause 6.3.1 and clause 7.3. It outlines the information that may be shared between O-DUs for transfer of user data and control information.

| + +## 6.4 Solution 3: Dual Connectivity + +### 6.4.1 Solution description + +Dual Connectivity (DC) is a well defined spectrum aggregation technique specified by 3GPP in TS 38.331 [i.9] and TS 38.420 [i.10]. F1 and Xn interfaces, as described in 3GPP TS 38.473 [i.12] and 3GPP TS 38.423 [i.13], provide connection between relevant RAN nodes. There are master node (MN) and secondary node (SN) that together are used to provide connectivity to the UE using Xn or F1 interface as shown in Figure 6.4.1-1 which results in better throughput. Data exchange takes place at PDCP PDU level in DC. O-DU is transparent for data transfer in DC technique. For O-DUs, there are two separate links established in downlink and uplink direction for a particular UE for data and control (UCI) information exchange. Figure 6.4.1-1 indicates the DC between multiple O-CU-CPs/O-CU-UPs. O-CU-CP/O-CU-UP/O-DU or O-RU can be supported by the same vendor or different vendors. + +![Figure 6.4.1-1: DC across multiple O-CU-CP/O-CU-UP. The diagram shows a Master Node (MN) and a Secondary Node (SN) connected via Xn interfaces. Each node contains an O-CU-CP/O-CU-UP block, an O-DU block, and an O-RU block. The O-CU-CP/O-CU-UP blocks are connected to the O-DU blocks via F1 interfaces. The O-DU blocks are connected to the O-RU blocks via Open FH interfaces. The O-RU blocks are connected to a UE block. A legend on the right indicates: PUCCH (dashed line with arrow), DL Data (solid line with arrow), Signalling (dashed line with double arrow), and UL Data (solid line with arrow).](ab03ecad666ebbea98b159d985be7c37_img.jpg) + +Figure 6.4.1-1: DC across multiple O-CU-CP/O-CU-UP. The diagram shows a Master Node (MN) and a Secondary Node (SN) connected via Xn interfaces. Each node contains an O-CU-CP/O-CU-UP block, an O-DU block, and an O-RU block. The O-CU-CP/O-CU-UP blocks are connected to the O-DU blocks via F1 interfaces. The O-DU blocks are connected to the O-RU blocks via Open FH interfaces. The O-RU blocks are connected to a UE block. A legend on the right indicates: PUCCH (dashed line with arrow), DL Data (solid line with arrow), Signalling (dashed line with double arrow), and UL Data (solid line with arrow). + +**Figure 6.4.1-1: DC across multiple O-CU-CP/O-CU-UP.** + +In addition, DC can also be used when a UE is connected to two O-DUs, O-DU1/O-RU1 from vendor "a" serving as MCG and the O-DU2/O-RU2 from vendor "b" serving as SCG, connected to the same O-CU-CP/O-CU-UP as shown in Figure 6.4.1-2. O-DU and O-RU can also be provided by the same vendor or different vendors. + +![Figure 6.4.1-2: DC with single O-CU-CP/O-CU-UP with multiple O-DUs. The diagram shows a Mobile Network (MN) and a Service Network (SN) connected via a single O-CU-CP/O-CU-UP. The MN contains O-DU1 and O-RU1, while the SN contains O-DU2 and O-RU2. The UE is connected to both O-RU1 and O-RU2. The O-CU-CP/O-CU-UP is connected to O-DU1 and O-DU2 via F1 interfaces. Open Fronthaul connections exist between O-DU1 and O-RU1, and between O-DU2 and O-RU2. The UE is connected to both O-RU1 and O-RU2 via dashed lines representing PUCCH, DL Data, UL Data, and Signalling.](3a458358163869c525fbb29a1fbdaece_img.jpg) + +Figure 6.4.1-2: DC with single O-CU-CP/O-CU-UP with multiple O-DUs. The diagram shows a Mobile Network (MN) and a Service Network (SN) connected via a single O-CU-CP/O-CU-UP. The MN contains O-DU1 and O-RU1, while the SN contains O-DU2 and O-RU2. The UE is connected to both O-RU1 and O-RU2. The O-CU-CP/O-CU-UP is connected to O-DU1 and O-DU2 via F1 interfaces. Open Fronthaul connections exist between O-DU1 and O-RU1, and between O-DU2 and O-RU2. The UE is connected to both O-RU1 and O-RU2 via dashed lines representing PUCCH, DL Data, UL Data, and Signalling. + +**Figure 6.4.1-2: DC with single O-CU-CP/O-CU-UP with multiple O-DUs.** + +DC can also be combined with CA to further improve coverage and throughput. In this case, both or either of the nodes providing DC connectivity will have their own CC legs for carrier aggregation. CA can be Intra O-DU as shown for the MN node or Inter O-DU as shown for the SN node in Figure 6.4.1-3 below. Both the CA techniques are described in clause 6.2 and clause 6.3. The related requirement and details for the CA solutions are described in the respective clauses and DC will not impose any new requirement for supporting this scenario. + +![Figure 6.4.1-3: Intra/Inter O-DU DL CA with DC. The diagram shows a Mobile Network (MN) and a Service Network (SN) connected via NG interfaces. The MN contains O-CU-CP1/O-CU-UP1, O-DU1, and O-RU1/O-RUm. The SN contains O-CU-CP2/O-CU-UP2, O-DU2/O-DUn, and O-RUx/O-RUy. The O-CU-CP1/O-CU-UP1 and O-CU-CP2/O-CU-UP2 are connected via Xn interfaces. The O-CU-CP1/O-CU-UP1 is connected to O-DU1 via F1 interfaces. The O-CU-CP2/O-CU-UP2 is connected to O-DU2/O-DUn via F1 interfaces. Open FH connections exist between O-DU1 and O-RU1/O-RUm, and between O-DU2/O-DUn and O-RUx/O-RUy. The UE is connected to both O-RU1/O-RUm and O-RUx/O-RUy via dashed lines representing PUCCH, DL Data, UL Data, and Signalling.](77ffb9cd2d6005cab47f45cc0f5774ce_img.jpg) + +Figure 6.4.1-3: Intra/Inter O-DU DL CA with DC. The diagram shows a Mobile Network (MN) and a Service Network (SN) connected via NG interfaces. The MN contains O-CU-CP1/O-CU-UP1, O-DU1, and O-RU1/O-RUm. The SN contains O-CU-CP2/O-CU-UP2, O-DU2/O-DUn, and O-RUx/O-RUy. The O-CU-CP1/O-CU-UP1 and O-CU-CP2/O-CU-UP2 are connected via Xn interfaces. The O-CU-CP1/O-CU-UP1 is connected to O-DU1 via F1 interfaces. The O-CU-CP2/O-CU-UP2 is connected to O-DU2/O-DUn via F1 interfaces. Open FH connections exist between O-DU1 and O-RU1/O-RUm, and between O-DU2/O-DUn and O-RUx/O-RUy. The UE is connected to both O-RU1/O-RUm and O-RUx/O-RUy via dashed lines representing PUCCH, DL Data, UL Data, and Signalling. + +**Figure 6.4.1-3: Intra/Inter O-DU DL CA with DC.** + +In the case of spectrum aggregation by DC, MLB can be done via F1 and X2/Xn interface. + +### 6.4.2 Mapping to deployment scenarios and other consideration + +Deployment use cases defined in clause 5.2.1.2, 5.2.1.3 and 5.2.2 for inter band spectrum aggregation can be supported with DC solution. 3GPP has defined lesser number of band combinations as compared to CA. This limits the benefits of spectrum aggregation in case MNO wants to apply them to legacy UEs. As there are multiple uplink links for DC, energy consumption at UE will be higher compared to DL CA but multiple UL links can also improve UL throughput. + +### 6.4.3 Impact analysis on specifications + +Xn and F1 interfaces are well defined in 3GPP specifications. There is no impact on O-RAN working groups. + +### 6.4.4 Feasibility and gain/complexity analysis + +Table 6.4.4-1 evaluates the Dual Connectivity solution with respect to solution evaluation criteria. + +**Table 6.4.4-1: Evaluation of Dual Connectivity.** + +| Solution evaluation criteria | Remarks | +|---------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Minimize complexity | No Impact. This is already standardized solution. | +| Minimize impact to inter-operability testing and standardization effort | No Impact. This is already standardized solution. | +| Increase performance and lower latency | Performance depends on the MN-SN flow control which is at higher level at the PDCP layer. | +| Minimize impact on O-RAN architecture | No Impact. DC is a standard solution. | +| Minimize UE impact | No Impact. DC is a standard solution. | +| Align with 3GPP RAN design | No Impact. DC is a standard solution. | +| Increase spectral efficiency of combined carriers | Lesser number of band combinations for DC specified by 3GPP as compared to CA [i.11]. | +| Increase coverage and capacity | Coverage in DC is lesser compared to CA [i.7]. In DC, for each carrier, there is a separate UL PUCCH link for feedback on DL data. This limits the coverage of each DC carrier compared to CA. | +| Address security concerns with different solutions | No impact. DC is a standard solution. | +| Minimize energy consumption | In DC each carrier will have its own UL link for receiving UL data as well as PUCCH. Due to multiple UL links, power consumption at UE is higher compared to CA. | +| Minimize exchange of scheduling-specific information over open interfaces | No information exchange as data split is at higher level. | + +# 7 Conclusions and recommendations + +## 7.1 Summary of evaluation + +In the present document different deployment scenarios are described which are relevant to spectrum aggregation. For a multi-vendor network deployment, the following spectrum aggregation solutions are documented. + +- Intra O-DU CA +- Inter O-DU CA +- Dual connectivity + +Figure 7.1-1 summarizes the key properties of the three spectrum aggregation solutions. Intra O-DU CA relies on Open FH interface (PHY layer) which enables multi vendor O-RUs. Inter O-DU CA using the D2 interface interconnects the two MAC layers in separate O-DUs. Dual connectivity makes use of PDCP aggregation at the O-CU-UP level. Depending on deployment scenario, one of the three solutions or a combination thereof can be used for spectrum aggregation. A decision tree to help arrive at a solution, considering different deployment scenarios, is described in Annex C. + +![Figure 7.1-1: High-level depiction of the three solutions. The diagram shows three network architectures: 1. Intra O-DU CA: A single O-CU-UP/O-CU-CP block connects to a single O-DU1 block via F1. O-DU1 connects to multiple O-RU blocks (O-RU1, O-RU2, ..., O-RUn) via Open FH. A UE connects to all O-RUs. 2. Inter O-DU CA: A single O-CU-UP/O-CU-CP block connects to O-DU1 and O-DU2 via F1. O-DU1 and O-DU2 are connected via D2. O-DU1 connects to O-RU1, O-RU2, and O-RUn via Open FH. O-DU2 connects to O-RUn. A UE connects to all O-RUs. 3. Dual connectivity: A single O-CU-UP/O-CU-CP block connects to O-DU1 and O-DU2 via F1. O-DU1 connects to O-RU1, O-RU2, and O-RUn via Open FH. O-DU2 connects to O-RU3 and O-RUn. A UE connects to all O-RUs. Labels 'Can be new vendor' are present for O-DU2 and O-RUn in the Inter O-DU CA and Dual connectivity scenarios.](958d0ce37a681fa643470763f78e5870_img.jpg) + +Figure 7.1-1: High-level depiction of the three solutions. The diagram shows three network architectures: 1. Intra O-DU CA: A single O-CU-UP/O-CU-CP block connects to a single O-DU1 block via F1. O-DU1 connects to multiple O-RU blocks (O-RU1, O-RU2, ..., O-RUn) via Open FH. A UE connects to all O-RUs. 2. Inter O-DU CA: A single O-CU-UP/O-CU-CP block connects to O-DU1 and O-DU2 via F1. O-DU1 and O-DU2 are connected via D2. O-DU1 connects to O-RU1, O-RU2, and O-RUn via Open FH. O-DU2 connects to O-RUn. A UE connects to all O-RUs. 3. Dual connectivity: A single O-CU-UP/O-CU-CP block connects to O-DU1 and O-DU2 via F1. O-DU1 connects to O-RU1, O-RU2, and O-RUn via Open FH. O-DU2 connects to O-RU3 and O-RUn. A UE connects to all O-RUs. Labels 'Can be new vendor' are present for O-DU2 and O-RUn in the Inter O-DU CA and Dual connectivity scenarios. + +Figure 7.1-1: High-level depiction of the three solutions. + +Table 7.1-1 covers the mapping of different deployment scenarios with the various solutions defined in clause 6. + +Table 7.1-1: Mapping with deployment scenarios. + +| Deployment Scenario | DC | Intra O-DU CA | Inter O-DU CA | +|----------------------------|-----------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------|--------------------------------------------------------------------| +| Co-located deployments | Supported. | Supported. | Supported. | +| Non-co-located deployments | Supported and capable of supporting distributed O-DUs connected via non-ideal backhaul. | Supported with ideal fronthaul. Fronthaul latency up to High200 can be supported. | Supported with ideal transport link or with latency up to High200. | + +Table 7.1-2 captures the details of each solution against the considerations mentioned in clause 5.3. + +**Table 7.1-2: Considerations table.** + +| Considerations for each solution | DC | Intra O-DU CA | Inter O-DU CA | +|-------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| UE considerations: Maximize CC combinations based on UE capability | In 3GPP Rel 15 specifications, DC is supported only between FR1 and FR2 bands. Also, NR DC support was added later in Rel 15 specification. Hence UEs supporting 3GPP Rel 15 UEs without NR-DC capability will be limited in CC combinations. Most of the UEs in the market are supporting 3GPP Rel 15 and EN-DC. | As majority of the 5G UEs are supporting 3GPP Rel 15. These UEs are also not supporting NR-DC as well, hence CA can improve CC combinations for spectrum aggregation. (NOTE) | Current majority of the 5G UEs are supporting 3GPP Rel 15. These UEs are also not supporting NR-DC as well, hence CA can improve CC combinations for spectrum aggregation. (NOTE) | +| UE consideration: Energy consumption | In DC, two separate paths for UL & DL direction, one for SCG and MCG, are always present. If there is no UL data, presence of two UL links will increase the power consumption at UE. | In DL CA, multiple UL links across different carriers are not required. Hence, this can reduce power consumption at UE. If DL and UL CA both are active, power consumption at UE can be higher due to the presence of 2 UL links. | In DL CA, multiple UL links across different carriers are not required. Hence, this can reduce power consumption at UE. If DL and UL CA both are active, power consumption at UE can be higher due to presence of 2 UL links. | +| Spectrum consideration: FDD+TDD | Coverage of mid band will improve around 67% [i.7] | Coverage of mid band will improve around 85% [i.7] | Coverage of mid band can improve and may be similar to intra O-DU CA scenario. | +| Spectrum consideration: SUL/SDL | N/A | SUL/SDL carrier in Intra O-DU CA can be used for coverage and performance improvement | SUL/SDL carrier in inter O-DU CA can be used for coverage and performance improvement. | +| Synchronization consideration | Both synchronous and asynchronous deployments are supported. | All the carriers reside in the same O-DU, therefore no additional synchronization requirements apply. | Tight synchronization (maximum clock timing difference cannot be larger than 33 $\mu$ s) between O-DUs is needed for supporting inter O-DU CA. | +| Network management considerations | No additional considerations. | No additional considerations. | SMO can manage the interface between O-DUs. The existing O1 interface between SMO and O-DU can be extended to bring in the configuration for functioning of the new interface. | +| NOTE: This is dependent on the UE capability support for different 3GPP releases and NR-DC, which can change in future. | | | | + +As there are multiple techniques that can be used for spectrum aggregation, evaluation criteria defined in clause 5.3.6 is used to evaluate each solution. Based on the evaluation criteria, Table 7.1-3 compares the three solutions. + +**Table 7.1-3: Comparison of solution evaluation.** + +| Solution evaluation criteria | Dual connectivity | Intra O-DU CA | Inter O-DU CA | +|-------------------------------------------------------------------------|-------------------|---------------|-------------------------------------------------------------------------------| +| Minimize complexity | No impact. | No impact. | A new interface needs to be defined between the O-DUs. | +| Minimize impact to inter-operability testing and standardization effort | No impact. | No impact. | As a new interface will be defined, it will have impact on inter-operability. | + +| Solution evaluation criteria | Dual connectivity | Intra O-DU CA | Inter O-DU CA | +|---------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Increase performance and lower latency | For non-ideal backhaul, DC is the preferred solution. For cell center condition, performance can be similar to inter O-DU CA as UL PUCCH reception on both MCG and SCG links may not show any degradation. In cell edge scenarios, the SCG PUCCH link might be impacted and hence can cause retransmissions. This will impact the throughput. Also in this case, if SCG link drops, activation of the SCG link will take longer due to RRC signaling, which can further impact the performance. | More optimal usage of resources than any other spectrum aggregation technique and thus results in higher end user performance. Lower latency is achieved as spectrum aggregation is done in a single O-DU. | Despite O-DU being interconnected via transport system satisfying the transport requirement, the achieved performance could potentially be lower than intra O-DU CA. This performance degradation is seen as HARQ feedback from PCell to SCell will be delayed by the latency of the underlying transport connecting the O-DUs. Different scheduler running in O-DUs may have impact on performance and latency. | +| Minimize impact on O-RAN architecture | No impact. | No impact. | Impact on multiple WGs e.g., WG1, WG5, WG10, WG11 etc. | +| Minimize UE impact | No impact. | No impact. | No impact. | +| Aligns with 3GPP RAN design | Aligned. | Aligned. | Aligned. | +| Increase spectral efficiency of combined carriers | Spectral efficiency of DC can be lower in certain scenario (e.g when UE is power limited) due to presence of separate PUCCH link for SCG cell. | Spectral efficiency of CA can be higher due to the reception of SCell PUCCH on PCell, CA can be activated faster than DC which enables optimal usage of available resources and thus improving the overall spectral efficiency. | Spectral efficiency of CA can be higher due to the reception of SCell PUCCH on PCell. CA can be activated faster than DC which enables optimal usage of available resources. However, in Inter O-DU case, delayed HARQ feedback reception at SCell due to transport delay across O-DUs and the need for flow co-ordination among different schedulers can impact overall spectral efficiency. | +| Increase coverage and capacity (Number of users) | Maintenance of two separate UL links, lowers the coverage and capacity gains compared to Intra and Inter O-DU CA. | CA enables maximum coverage and capacity extension of mid/high bands by moving UL control to low/mid band. | Coverage and capacity gain of inter O-DU CA is expected to be similar to intra O-DU CA. | +| Address security concerns with different solutions | DC is a well-defined solution in 3GPP and ORAN so no new security requirements. | Intra O-DU CA is a well-defined solution in 3GPP and ORAN so no new security requirements. | Inter O-DU CA is a new solution hence security aspects need to be defined for the new interface. Existing techniques that are used on F1 can be considered. | +| Minimize exchange of scheduling-specific information over open interfaces | No exchange of scheduling information as data exchange is at higher level | No exchange of scheduling information as CA is within one O-DU | The new interface can be designed such that the input for scheduling the UE (data buffer size etc) can be exchanged without disclosing the proprietary scheduling algorithms and policies. | + +As shown in Table 7.1-1, Table 7.1-2 and Table 7.1-3, for supporting spectrum aggregation across non-co-located nodes with non-ideal backhaul, DC is a preferred option. DC can support spectrum aggregation in non-synchronized components. It is a well defined solution in 3GPP and O-RAN. DC is the preferred option for spectrum aggregation between FR1 and FR2. + +Table 7.1-2 indicates that CA has more band combinations (also see Table 6.2.2-1) defined in 3GPP specifications. Spectrum aggregation across intra band carriers cannot be achieved by NR DC. CA provides better coverage and capacity compared to DC for mid/high band aggregated with low band cells. If multiple cells are supported in single O-DU, intra O-DU CA with/without Shared O-RU solution can be utilized for spectrum aggregation across different bands to achieve the best coverage and capacity results with least energy consumption. + +In a deployment scenario, where different frequency bands are supported in different O-DUs or if an O-DU instance cannot host further cells due to its processing limits, inter O-DU CA (assuming legacy O-DU can be upgraded to support new interface) can be used for achieving the benefits of carrier aggregation. This will be beneficial for both co-located and non-co-located deployments. The new interface between O-DUs can be specified within the transport latency requirements as described in clause 6.3.1. Coverage and capacity (in terms of users) improvement can be similar to the intra O-DU CA solution. The new interface between O-DUs can provide further flexibility to the MNOs to install RAN NFs as per their need and from different vendors. + +## 7.2 Impact on standardization + +For intra O-DU CA multi-O-RU scenario and dual connectivity, there is no impact on any WG as it is specified in 3GPP and O-RAN specifications. For intra O-DU CA with shared O-RU, WG4 enhancements may be needed to support dynamic carrier sharing. + +There is no direct standardized inter O-DU interface defined in 3GPP or in O-RAN. For supporting inter O-DU carrier aggregation, a new inter O-DU interface, referred to as D2, needs to be defined. Table 6.3.3-1 details the WGs and the specifications impact of standardizing the proposed interface. + +Based on the prior Open FH experience, the development timeline of D2 interface is expected to be about 2 years from the start of the work item until the specification can be considered robust enough for the implementation. + +## 7.3 Recommendations + +The objective of this study is to evaluate spectrum aggregation techniques (carrier aggregation and dual connectivity) in both co-located and non-co-located scenarios utilizing specific assessment criteria. As shown in Table 7.1-1, Table 7.1-2 and Table 7.1-3, dual connectivity is appropriate when a user equipment (UE) connects to two separate cells concurrently, typically with different frequencies (e.g., FR1 and FR2) over non-ideal backhaul links. + +In intra O-DU CA (shared O-RU or multi-O-RU) O-DUs, O-RUs can be provided by different vendors. Intra O-DU CA provides the best coverage and capacity improvement in spectrum aggregation. It can be used in co-located scenarios or deployments where single O-DU will be supporting multiple cells connected to different O-RUs. For non-co-located deployment use cases of clause 5.2.2, this solution can cover all scenarios if the fronthaul connecting the O-RU and O-DU has latency within the latency classes of High25, High75 of Table A-1. The High100 and High200 latency classes can also be supported depending on implementation and performance trade-offs. + +Multi-vendor dual connectivity and intra O-DU CA are well-defined in 3GPP specifications and are supported by O-RAN. + +For catering to deployment scenarios where different frequency bands are supported in different O-DUs or if an O-DU instance cannot host further cells due to its processing limits, multi-vendor inter O-DU CA can be used for achieving the benefits of spectrum aggregation. This will be beneficial for both co-located and non-co-located deployments. This assumes that legacy O-DUs are upgradable to support the new inter O-DU interface. + +# Annex A: Xhaul delay considerations + +This annex presents the Xhaul (Fronthaul, Midhaul and Backhaul) one way delay requirements captured in O-RAN.WG9.XTRP-REQ-v01.00 [i.2]. + +Table A-1 lists one-way delay requirements for fronthaul. + +**Table A-1: Fronthaul one-way delay requirement table, adapted from clause 7.2 of [i.2].** + +| Latency class | Max. one-way frame delay performance | Use case | +|---------------|--------------------------------------|--------------------------------------------------------------| +| High25 | 25 $\mu$ s | Ultra-low latency performance | +| High75 | 75 $\mu$ s | For full NR performance with fiber lengths in 10km range | +| High100 | 100 $\mu$ s | For full NR performance with fiber lengths in 10km range | +| High200 | 200 $\mu$ s | For standard NR performance with fiber lengths in 10km range | +| High500 | 500 $\mu$ s | Large latency installations > 30 km | +| Medium | 1 ms | User Plane (slow) & C&M Plane (fast) | +| Low | 100 ms | C&M Plane | + +Table A-2 lists the one-way end to end Midhaul transport delay requirements. + +**Table A-2: One-way end to end Midhaul transport delay table, adapted from clause 8.2 of [i.2].** + +| Capability | Requirements | Notes | +|----------------------------------------------|---------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| End to end Midhaul transport delay (one way) | <1.5 ms-10 ms [i.3] | Delay constraints for midhaul are derived mainly from the target service's latency requirements, rather than specific requirements of the Midhaul' s user or control planes. As service delay targets become tighter it may become necessary to:
1) Place Midhaul and Backhaul mobile components in close proximity to each other to reduce the delay impact of the transport network.
2) Combine mobile functions together so 3GPP interfaces run internally within a "Network Function" or within a data center to remove the delay impact associated with the WAN transport network. For example, combining O-RU, O-DU and O-CU-CP/UP or combining the O-DU and O-CU-CP/UP functions together. | + +Table A-3 lists the one-way end to end Backhaul transport delay requirements. + +**Table A-3: One-way end to end Backhaul transport delay requirements, adapted from clause 9.3 of [i.2].** + +| Capability | Requirements | Notes | +|-----------------------------------------------|---------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| End to end Backhaul transport delay (one way) | 1 ms – 50 ms service dependent. |

Delay constraint for Backhaul are derived mainly from the target service's latency requirements, rather than specific requirements of the Backhaul's user or control planes. As service delay targets become tighter it may become necessary to:

1) Place Midhaul and Backhaul mobile components in close proximity to each other to reduce the delay impact of the transport network. For example, O-DU, O-CU-CP/UP and UPF in the same data center.

2) Combine mobile functions together so 3GPP interfaces run internally within a "Network Function" or within a data center to remove the delay impact associated with the WAN transport network. For example, combining O-RU, O-DU and O-CU-CP/UP or combining the O-DU and O-CU-CP/UP functions together.

| + +# Annex B: Examples of multi-vendor Inter O-DU interface + +## B.1 DL CA using an Inter O-DU interface + +In Figure B.1-1, DL CA between two O-DUs for 2 UEs are shown. In Figure B.1-1, 2 O-DUs are present in the system connected to the same O-CU-UP/O-CU-CP. O-DU1 is configured as PCell for UE1 while O-DU2 is configured as SCell. For UE2, O-DU2 is serving as PCell while O-DU1 is hosting the SCell. + +As both the UEs are using O-DUs for inter O-DU CA, for UE1, RLC is hosted in O-DU1. Data is received from O-CU-UP by O-DU1 and data is shared with O-DU2 if SCell is activated. PUCCH for UE1 is also received by O-DU1 and then shared with O-DU2. For UE2, the same functionality will be observed in O-DU2 (hosting RLC, RRC connection management and receiving data from O-CU-UP). + +![Figure B.1-1: Inter O-DU CA for multiple UEs hosting PCells in different O-DUs. The diagram shows two O-DUs (O-DU1 and O-DU2) connected to a central O-CU-CP/O-CU-UP block. UE1 is connected to O-DU1, and UE2 is connected to O-DU2. Each O-DU contains RLC, MAC, and PHY layers. Data flows from O-CU-CP/O-CU-UP to O-DU1 and O-DU2. For UE1, data flows from O-DU1 to UE1. For UE2, data flows from O-DU2 to UE2. Inter-DU data sharing is shown between O-DU1 and O-DU2 for both UE1 and UE2. A legend indicates that for UE1, DL Data and PUCCH are received by O-DU1, and for UE2, DL Data and PUCCH are received by O-DU2.](f2b2637a2253bd66f62938967ef1dd30_img.jpg) + +Figure B.1-1: Inter O-DU CA for multiple UEs hosting PCells in different O-DUs. The diagram shows two O-DUs (O-DU1 and O-DU2) connected to a central O-CU-CP/O-CU-UP block. UE1 is connected to O-DU1, and UE2 is connected to O-DU2. Each O-DU contains RLC, MAC, and PHY layers. Data flows from O-CU-CP/O-CU-UP to O-DU1 and O-DU2. For UE1, data flows from O-DU1 to UE1. For UE2, data flows from O-DU2 to UE2. Inter-DU data sharing is shown between O-DU1 and O-DU2 for both UE1 and UE2. A legend indicates that for UE1, DL Data and PUCCH are received by O-DU1, and for UE2, DL Data and PUCCH are received by O-DU2. + +Figure B.1-1: Inter O-DU CA for multiple UEs hosting PCells in different O-DUs. + +## B.2 High-level description of Inter O-DU interface (D2) + +For supporting inter O-DU CA, a new interface between the O-DUs need to be defined. Figure B.2-1 below proposes the solution for inter O-DU CA where D2 identifies the new interface. + +![Figure B.2-1: D2 interface between O-DUs. The diagram shows a high-level architecture with three O-CU-CP/O-CU-UP blocks (O-CU-CP1/O-CU-UP1, O-CU-CP2/O-CU-UP2, and O-CU-CPn/O-CU-UPn) connected via NG interfaces. These are connected to O-DU1, O-DU2, and O-DUn respectively via F1 interfaces. The O-DUs are interconnected via D2 interfaces. Each O-DU is connected to an O-RU (O-RU1, O-RU2, O-RUn) via Open FH interfaces.](aff57c583736b2909b84037b38d635e5_img.jpg) + +Figure B.2-1: D2 interface between O-DUs. The diagram shows a high-level architecture with three O-CU-CP/O-CU-UP blocks (O-CU-CP1/O-CU-UP1, O-CU-CP2/O-CU-UP2, and O-CU-CPn/O-CU-UPn) connected via NG interfaces. These are connected to O-DU1, O-DU2, and O-DUn respectively via F1 interfaces. The O-DUs are interconnected via D2 interfaces. Each O-DU is connected to an O-RU (O-RU1, O-RU2, O-RUn) via Open FH interfaces. + +Figure B.2-1: D2 interface between O-DUs. + +Interface between O-DUs can be defined such that transport requirement as defined in clause 6 can be met. Coverage and capacity improvement can be similar to the intra O-DU CA. A new interface between O-DUs can provide further flexibility to the MNOs to install RAN NFs as per their need and from different vendors. + +There are two parts of the D2 interface: + +- D2-C: Exchange of control information. SCTP can be used as transport protocol. Link establishment between O-DUs, SCell establishment/release can be taken care by the control part of the D2 interface. +- D2-U: Exchange of data and PUCCH information will be taken care of by the D2-U interface. GTP-U is used for transport mechanisms. + +``` +@startUML +Skinparam titleBorderRoundCorner 25 +skinparam titleBorderThickness 2 +skinparam titleBorderColor red +skinparam titleBackgroundColor Coral +skinparam titleFontSize 20 +participant "O-CU-CP/O-CU-UP" as CU +participant "Primary O-DU" as pDU +participant "Secondary O-DU" as sDU +participant UE +pDU->sDU : D2 Setup Request +sDU -> pDU : D2 Setup Response +Note over pDU : SCell can be added only if D2 setup is successful. +CU -> pDU : UE Context Setup/Modification Request (SCell from other O-DU) +pDU -> sDU : SCell Addition Request +sDU->pDU : SCell Addition Response +pDU-> CU : UE Context Setup/Modification Response +Note over pDU : SCell can be activated only if SCell Addition is successful. +CU->pDU : User Data +pDU -> sDU : Buffer Indication +sDU->pDU : Data Request +pDU -> sDU : Data and PUCCH resource allocation +pDU-> UE : PDCCH and PDSCH Data +sDU-> UE : PDCCH and PDSCH Data +UE->pDU : PUCCH Indication (UCI Information) +pDU->sDU : PUCCH/UCI Indication +@endUML +``` + +Figure B.2-2 shows a proposed message flow for the D2 interface. + +![Sequence diagram showing message flow for D2 interface between O-CU-CP/O-CU-UP, Primary O-DU, Secondary O-DU, and UE.](e0e3c20519c7abc406f301d14ab88d2b_img.jpg) + +``` + +sequenceDiagram + participant OCU as O-CU-CP/O-CU-UP + participant PODU as Primary O-DU + participant SODU as Secondary O-DU + participant UE + + PODU->>SODU: D2 Setup Request + SODU-->>PODU: D2 Setup Response + Note over PODU: SCell can be added only if D2 setup is successful. + OCU->>PODU: UE Context Setup/Modification Request (SCell from other O-DU) + PODU->>SODU: SCell Addition Request + SODU-->>PODU: SCell Addition Response + OCU-->>PODU: UE Context Setup/Modification Response + Note over PODU: SCell can be activated only if SCell Addition is successful. + OCU->>PODU: User Data + PODU->>SODU: Buffer Indication + SODU-->>PODU: Data Request + SODU->>PODU: Data and PUCCH resource allocation + PODU->>SODU: PDCCH and PDSCH Data + SODU->>UE: PDCCH and PDSCH Data + UE-->>PODU: PUCCH Indication (UCI Information) + PODU->>SODU: PUCCH/UCI Indication + +``` + +The diagram illustrates the message flow for the D2 interface between the O-CU-CP/O-CU-UP, Primary O-DU, Secondary O-DU, and the UE. The process begins with a D2 Setup Request from the Primary O-DU to the Secondary O-DU, followed by a D2 Setup Response. A note indicates that an SCell can only be added if the D2 setup is successful. The O-CU-CP/O-CU-UP then sends a UE Context Setup/Modification Request (SCell from other O-DU) to the Primary O-DU, which in turn sends an SCell Addition Request to the Secondary O-DU. The Secondary O-DU responds with an SCell Addition Response, and the Primary O-DU sends a UE Context Setup/Modification Response back to the O-CU-CP/O-CU-UP. Another note states that an SCell can only be activated if the SCell Addition is successful. The O-CU-CP/O-CU-UP then sends User Data to the Primary O-DU. The Primary O-DU sends a Buffer Indication to the Secondary O-DU, which responds with a Data Request. The Secondary O-DU then sends Data and PUCCH resource allocation to the Primary O-DU. The Primary O-DU sends PDCCH and PDSCH Data to the Secondary O-DU, which then forwards the PDCCH and PDSCH Data to the UE. The UE sends a PUCCH Indication (UCI Information) back to the Primary O-DU, which then forwards the PUCCH/UCI Indication to the Secondary O-DU. + +Sequence diagram showing message flow for D2 interface between O-CU-CP/O-CU-UP, Primary O-DU, Secondary O-DU, and UE. + +Figure B.2-2: Message flow for D2 interface. + +# Annex C:Spectrum aggregation solution decision tree analysis + +A decision tree is a useful tool to represent decision processes involving multiple decision points along different paths leading to a set of options. It helps in representing decision process in graphical form for better understanding of the decision process. Figure C-1 represents the decision tree for spectrum aggregation solutions. It takes into account key considerations that are discussed at length in the present document. They are listed along with their various possible values below for quick reference: + +- Existing-new spectrum FR + - FR1-FR1 + - FR1-FR2 + - FR2-FR2 +- Aggregated spectrum type + - Contiguous + - Non-contiguous +- Deployed O-DU capability + - Supports new spectrum. + - Does not support new spectrum. +- Added O-DU capability. + - Supports new spectrum only. + - Supports new+existing spectrum. +- Transport capability + - Delay/BW requirements met. + - Delay/BW requirements not met. +- Existing deployment + - SA + - NSA +- New spectrum duplex mode + - SDL/SUL + - TDD/FDD +- Specified combination + - DC + - CA + +The inter O-DU CA solution has an impact on O-RAN standardization. + +![Decision tree for spectrum aggregation solutions. The flow starts with 'Start' and goes through several decision points: 'Existing-new spectrum FR' (FR1-FR2), 'Deployed O-DU capability' (Supports new spectrum, Doesn't support new spectrum), 'Existing deployment' (SA, NSA), 'New spectrum duplex Mode' (TDD/FDD, SDL/SUL), 'Specified combination' (DC, CA), 'Aggregated spectrum type' (contiguous, non-contiguous), 'Transport capability' (Delay/BW requirements not met, Delay/BW requirements met), 'Added O-DU capability' (Supports new+existing spectrum, Supports new spectrum only). The final outcomes are 'Intra-O-DU CA', 'Inter-O-DU CA', 'Dual Connectivity', and 'End'.](594bc3aafabcc51cb96f2ebb85a0f343_img.jpg) + +``` + +graph TD + Start([Start]) --> D1{Existing-new spectrum FR} + D1 -- FR1-FR2 --> D2{Deployed O-DU capability} + D1 -- FR1-FR1, FR2-FR2 --> D2 + D2 -- Supports new spectrum --> Intra[Intra-O-DU CA] + D2 -- Doesn't support new spectrum --> D3{Existing deployment} + D3 -- SA --> D4{New spectrum duplex Mode} + D3 -- NSA --> D5{Aggregated spectrum type} + D4 -- TDD/FDD --> D6{Specified combination} + D4 -- SDL/SUL --> D5 + D6 -- DC --> DC[Dual Connectivity] + D6 -- CA --> D5 + D5 -- contiguous --> Upgrade[Upgrade O-DU] + D5 -- non-contiguous --> D7{Transport capability} + Upgrade --> Intra + D7 -- Delay/BW requirements not met --> Upgrade + D7 -- Delay/BW requirements met --> Add[Add O-DU] + Add --> D8{Added O-DU capability} + D8 -- Supports new+existing spectrum --> Intra + D8 -- Supports new spectrum only --> Inter[Inter-O-DU CA] + Intra --> End([End]) + Inter --> End + DC --> End + +``` + +Decision tree for spectrum aggregation solutions. The flow starts with 'Start' and goes through several decision points: 'Existing-new spectrum FR' (FR1-FR2), 'Deployed O-DU capability' (Supports new spectrum, Doesn't support new spectrum), 'Existing deployment' (SA, NSA), 'New spectrum duplex Mode' (TDD/FDD, SDL/SUL), 'Specified combination' (DC, CA), 'Aggregated spectrum type' (contiguous, non-contiguous), 'Transport capability' (Delay/BW requirements not met, Delay/BW requirements met), 'Added O-DU capability' (Supports new+existing spectrum, Supports new spectrum only). The final outcomes are 'Intra-O-DU CA', 'Inter-O-DU CA', 'Dual Connectivity', and 'End'. + +**Figure C-1: Decision tree for spectrum aggregation solutions.** + +The decision tree represents key considerations for an MNO to choose an optimal solution from different spectrum aggregation solutions. These considerations sufficiently address the scope of the study. However, there may be other considerations beyond those mentioned here depending on specific MNO deployment scenarios. + +# Annex: Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023-06-22 | 00.04 | Initial version approved by UCTG of WG1. | +| 2023-07-01 | 00.04.01 | Incorporated agreed Multi-Vendor equipment deployment architecture section from ERI-2023.06.14-WG1-D-UCTG-Spectrum-aggregation-scenarios-v01.pptx
Incorporated CRs: SAM-0001, NOK-001, NOK-002. | +| 2023-08-16 | 00.04.02 | Incorporated CRs: MAV-0002, MAV-0003. | +| 2023-08-30 | 00.04.03 | Incorporated CRs: MAV-0001. | +| 2023-09-19 | 00.04.04 | Incorporated CRs: ERI-0078, ERI-0081, NOK-0004. | +| 2023-09-19 | 00.05 | Accepted all changes with attendant editorial clean-up. | +| 2023-09-29 | 00.05.01 | Incorporated CRs: NOK-003, SAM-0002, DIS-0001. | +| 2023-10-12 | 00.05.02 | Incorporated CRs: ERI-0086. | +| 2023-10-16 | 00.05.03 | Incorporated CRs: NOK-0006, NOK-0007. | +| 2023-10-17 | 00.05.04 | Editorial changes as agreed in O-RAN UCTG meeting. | +| 2023-10-17 | 1.00 | O-RAN WG1 approval of the document | +| 2023-12-07 | 1.00.01 | Incorporated CRs: SAM-0003. | +| 2024-01-17 | 1.00.02 | Incorporated CRs: MAV-0041. | +| 2024-01-31 | 1.00.03 | Incorporated CRs: MAV-0042. | +| 2024-02-01 | 1.00.04 | Incorporated CRs: MAV-0043. | +| 2024-02-15 | 1.00.05 | Incorporated CRs: MAV-0044. | +| 2024-02-20 | 1.00.06 | Incorporated CRs: MAV-0046, KDD-0002. | +| 2024-03-12 | 1.00.07 | Incorporated CRs: ERI-0126 | +| 2024-03-28 | 1.00.08 | Incorporated CRs: MAV-0045, MAV-0048. Included editorial updates. | +| 2024-04-24 | 1.00.09 | Incorporated CRs: MAV-0047, MAV-0050, MAV-0049. | +| 2024-05-08 | 1.00.10 | Incorporated CRs: ERI-013. | +| 2024-05-09 | 1.00.11 | Incorporated CRs: SAM-0005. Includes editorial updates. | +| 2024-05-30 | 1.00.12 | Incorporated CRs: NOK-0250, MAV-0052, MAV-0053, MAV-0054, SAM-0006, SAM-0007. Includes resolution of review comments 1-41 and editorial updates. | +| 2024-06-09 | 1.00.13 | Incorporated editorial updates including review comments 42-44. | +| 2024-06-10 | 1.00.14 | Editorial updates. | +| 2024-06-12 | 1.00.15 | Editorial updates and corrections. | +| 2024-07-01 | 1.00.16 | Editorial updates and corrections. | +| 2024-07-10 | 1.00.17 | Editorial updates and corrections. | +| 2024-07-10 | 2.00 | Document ready for WG1 approval. | +| 2024-07-25 | 2.00.01 | Editorial corrections implementing WG1 voting period feedback. | +| 2024-07-26 | 2.00.02 | Table format correction implementing WG1 voting period feedback. | +| 2024-07-26 | 3.00 | Document approved by WG1. | \ No newline at end of file diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/497c638391dae365ad12f1ebd687c445_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/497c638391dae365ad12f1ebd687c445_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..008ff69f0900d366186f2f68e6ee8cbfc18c468e --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/497c638391dae365ad12f1ebd687c445_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09238b459f3ad3429d2ba3917bc267325e8584c48d205b49916cca0dba7fbd7c +size 4549 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2b90693e69025867d0dd05d8f98d4ef9b4bf8d2 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ed2f1f4ac06a8bc6ac44f6e3f61e762e6c8489952cf16d65bfea30fe61adb2af +size 4677 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/raw.md b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..5cb1ab2814e915580cbe64cd271dee6b11cb5e3a --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00/raw.md @@ -0,0 +1,827 @@ + + +# **O-RAN Work Group 1 (Use Cases and Overall Architecture)****SMO Intents-driven Management** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|---------------------------------------------------------------------------------|----| +| List of figures ..... | 4 | +| List of tables ..... | 4 | +| Foreword ..... | 5 | +| Modal verbs terminology ..... | 5 | +| Executive summary ..... | 5 | +| Introduction ..... | 5 | +| 1 Scope..... | 6 | +| 2 References..... | 6 | +| 2.1 Informative references..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 7 | +| 3.1 Terms..... | 7 | +| 3.2 Symbols..... | 7 | +| 3.3 Abbreviations ..... | 7 | +| 4 SMO Intent driven management concepts ..... | 7 | +| 4.1 Overview ..... | 7 | +| 4.2 Intents management in current industry landscape ..... | 8 | +| 4.2.1 Intent-driven Management in TMF ..... | 9 | +| 4.2.2 Intent-driven Management in 3GPP ..... | 10 | +| 5 SMO Intent driven management Use Cases ..... | 12 | +| 5.1 Overview ..... | 12 | +| 5.2 Use Case: External exposure of RAN Intent-driven management services..... | 13 | +| 5.2.1 Use Case flow: RAN management Intents capabilities discovery ..... | 14 | +| 5.2.2 Use Case flow: Handling of external RAN management Intents requests..... | 15 | +| 5.2.3 Use Case flow: RAN management Intents capabilities registration..... | 15 | +| 5.3 Use Case: Intent-driven management of RAN performance assurance ..... | 16 | +| 5.3.1 Use Case flow: Intent-driven management of RAN performance assurance..... | 17 | +| 5.4 Use Case: intent deadline ..... | 19 | +| 5.4.1 Use Case Flow: intent deadline..... | 19 | +| 6 Procedures for Intent-driven management..... | 19 | +| 6.1 Overview ..... | 19 | +| 6.2 Removal of intent..... | 19 | +| 6.2.1 Remove Intent ..... | 20 | +| 6.3 Assessment of the potential fulfilment and outcome of an intent ..... | 20 | +| 6.3.1 Probing the outcome of an intent..... | 21 | +| 6.3.2 Modify the intent probing..... | 21 | +| 6.4 Preferences on possible options for intents outcome ..... | 21 | +| 6.4.1 RMIO preferences for one of the offered intent options ..... | 23 | +| 6.5 Requesting intent reports and intent report generation ..... | 23 | +| 6.5.1 Requesting intent reports and intent report generation ..... | 24 | +| 6.6 Modification of requirements in an intent..... | 24 | +| 6.6.1 Flow 25 | | +| 6.7 Intent Negotiation..... | 25 | +| 6.7.1 Intent feasibility check ..... | 25 | +| 6.7.2 Intent exploration ..... | 25 | +| 6.7.3 Intent fulfilment..... | 25 | +| 7 Recommended SMO Intent driven management requirements ..... | 26 | +| 7.1 Overview ..... | 26 | +| 7.2 Requirements for intent management in SMO..... | 26 | +| 8 SMO Intent driven management Analysis..... | 27 | + +| | | | +|--------|-----------------------------------------------|----| +| 8.1 | Overview ..... | 27 | +| 8.2 | SMO Architecture ..... | 27 | +| 8.2.1 | SMO Architecture Considerations ..... | 27 | +| 8.2.2 | SMO Architecture Recommendations..... | 28 | +| 8.3 | SMO Intent-driven Management Interface ..... | 28 | +| 8.3.1 | Intent Management interface approach ..... | 28 | +| 8.3.2 | Interface summary ..... | 28 | +| 8.3.3 | Interface recommendations..... | 29 | +| Annex: | Change history/Change request (history) ..... | 30 | + +# --- List of figures + +No table of figures entries found. + +# --- List of tables + +| | | +|-----------------------------------------------------------------------------------------------------|----| +| Table 5.1-1: Actors used across the different RAN Intents-driven management use cases..... | 13 | +| Table 5.2.1-1: RAN management Intent discovery by external SMO consumers..... | 14 | +| Table 5.2.2-1: RAN management Intent service invocation handling by SME..... | 15 | +| Table 5.2.3-1: RMIH capabilities registration with SME ..... | 15 | +| Table 5.3.1-1: RAN management Intent for performance assurance of a set of O-RAN NFs instances..... | 18 | +| Table 5.4.1-1: Intent Deadline flow ..... | 19 | +| Table 6.2.1-1: Remove Intent flow ..... | 20 | +| Table 6.3.1-1: Probing for the potential fulfilment of an intent ..... | 21 | +| Table 6.4.1-1: Preferences regarding the possible outcome options for intents ..... | 23 | +| Table 6.5.1-1: Requesting intent reports and the intent report generation ..... | 24 | +| Table 6.6.1-1: Modification of existing intents..... | 25 | +| Table 7.2-1: Requirements for intent management in SMO ..... | 27 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +--- + +# Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Executive summary --- + +# Introduction + +Industry standards provide today increasing support for enhanced network automation, using management loops mechanisms with separation of concerns in the interactions between different management domains, or between service and business domains. The O-RAN SMO provides a range of RAN management services which can be exposed to other management domains (e.g., E2E Service Management, enterprise) or towards a business support system. + +While abstracting such details needed to manage a RAN (e.g., several O-RAN NFs and their connectivity), the intents are a means to allow consumers of SMO services to express their end goals, requirements and constraints for such a RAN instance in a simplified form. The intents focus on “what” and not on the “how”, which is left to the intent management handling logic to resolve. + +In O-RAN SMO, intents can have a wide range of applicability, and this allows external consumers like management, and/or business systems, to interact with the SMO by expressing their requirements and goals for RAN management in a simplified manner, without needing to be aware of all the details of the RAN models, and the various types of management and orchestration interfaces design. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document specifies the use cases and provides an initial analysis of the SMO Intents-driven management of the RAN, concluding with recommendations for requirements, the architecture and interfaces for RAN intents-driven management to be pursued in the next phase of the feature. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their longterm validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [i.1] [WG1.ARCH] O-RAN.WG1.O-RAN-Architecture-Description +- [i.2] [WG1.UCR] O-RAN.WG1.Use-Cases-Detailed-Specification +- [i.3] O-RAN.WG2.Non-RT-RIC-ARCH-TS-v02.00, "O-RAN Working Group 2; Non-RT RIC Architecture Technical Specification". +- [i.4] O-RAN-WG1.Decoupled-SMO-Architecture-TR: "O-RAN Working Group 1 (Use Cases and Overall Architecture) Decoupled SMO Architecture". +- [i.5] 3GPP TR 28.912 "Study on enhanced intent driven management services for mobile networks", Release 18, April 2023. +- [i.6] 3GPP TS 28.312 "Intent driven management services for mobile networks", Release 17, April 2023. +- [i.7] IG1253, "Intent in Autonomous Networks", v1.3.0, August 2022 +- [i.8] TR290, "Intent Common Model", v3.0.0, February 2023 +- [i.9] TMF921, "Intent management API", Release 23.0.0, v4.0.0, March 2023 +- [i.10] IG1251, "Autonomous Networks – Reference Architecture", v1.0.1, September 2022 + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +**Intent:** formal specification of all requirements including goals and constraints given to a system. + +**Intent Expression:** representation of an intent, which captures the requirements, objectives, and related details. + +**Intent Driven Object:** object identifying a set of vocabulary and semantics used to capture and express intent. + +## 3.2 Symbols + +For the purposes of the present document, no special symbols apply. + +## 3.3 Abbreviations + +For the purposes of the present document, the [following] abbreviations [given in ... and the following] apply: + +| | | +|------|--------------------------------------| +| BSS | Business Support System | +| CM | Configuration Management | +| FM | Fault Management | +| KPI | Key Performance Indicators | +| LCM | LifeCycle Management | +| NBI | NorthBound Interface | +| NF | Network Function | +| OSS | Operational Support System | +| O-RU | O-RAN Radio Unit | +| PM | Performance Mangement | +| SMO | Service Management and Orchestration | +| SMOS | SMO Service | + +# --- 4 SMO Intent driven management concepts + +## 4.1 Overview + +An intent specifies the expectations including requirements, goals, and constraints, without specifying how the expectations should be fulfilled. In short, an intent is a statement or specification on the desired state of the system. Following are some general concepts for intent: + +- An intent is understandable by both humans as well as the machines without any ambiguity. +- An intent specifies “what” needs to be achieved without specifying “how” it can be done. + +The expectations expressed by an intent is agnostic to the underlying system implementation, technology, and infrastructure. Intents are a means to allow consumers of SMO Services to express their end goals, requirements and constraints, and then allows the SMO Service Producers, nonRT-RIC, and relevant rApps to figure out how to execute + +the realization of that intent. Advanced options can also be available, such as consumer making feasibility inquiries using various sets/subsets of its requirements or to obtain the possible available options for certain requirements. + +In O-RAN SMO, intents can have a wide range of applicability including the various interactions within SMO management loops (closed, open), serving as a simplified method for management exposure of RAN services both externally and internally to other management or business systems. The external exposure allows external management and business entities to interact with the SMO by expressing their requirements and goals for RAN instances in a simplified manner, without needing to be aware of all the details of the RAN models and the various types of management and orchestration interfaces design. An example of such external management service can be an E2E Service Management (E2E SM) system that is tasked to create and maintain a 5G service which includes all the access/RAN, core, transport and cloud services needed. Internally, different SMOS producers and rApps can use intents to interact with each other for different RAN management related tasks. Using intents would simplify the interactions and minimize dependencies between the consuming and producing entity of the management service, e.g., E2E SM entity, or a BSS, and the O-RAN SMO. + +A simplified approach of the SMO NBI, SMOS exposure, and R1 using intent-based management is beneficial, for the following reasons: + +- (a) Separation of concerns, between SMO and other management entities in OSS or BSS, which do not need to have a detailed knowledge of the O-RAN information models and data models to be able to request an O-RAN service. +- (b) Ability for SMOS producers to produce and/or consumer intent based services (be it SMO framework services or SMOS realized via rApps). +- (c) Enable an evolution path of the SMO towards knowledge-driven management systems, where machine reasoning capabilities can process received O-RAN intents, perform data inference when needed and are easily extensible. +- (d) Establish a common intent management framework in the SMO that can handle the O-RAN service level management via intents, which can be reused and extended as necessary. The extensions to add further scoping of O-RAN intents can be done by simply defining their intent models (since the interface definition and intent management framework are reusable throughout the SMO). +- (e) Leverage existing standardization work on intents management, specifically intent interfaces, models, and management aspects such as intent capabilities tracking (registration, discovery), such as TM Forum's TR290X, TR291X, TR292X, TR293, TMF921A and GB921, 3GPP TS 28.312, 3GPP TR 28.912, ETSI GR ZSM011 and ETSI GS ZSM016, etc. + +### 4.1.1 Overview on intent negotiation procedures + +Intent negotiation procedures help the RMIO (an authorized consumer of the SMO services) to find the best possible way to fulfil an intent. These procedures are important since they help the RMIO and RMIH engage with each other in a collaborative way that is beneficial for both. When an intent is provided to the RMIH, it can go either of the two ways: + +- Pre-evaluation/Exploration: if the intent is provided to RMIH for pre-evaluation/exploration, nothing in the network or the system (including SMO) changes. Intent negotiation in this phase includes: + - intent feasibility check: this enables the RMIO to understand if an intent can be supported by the RMIH. The output of this phase is binary: FEASIBLE or INFEASIBLE. + - intent exploration: the output of this phase is non-binary. This enables the RMIO to understand what can be achieved with respect to the expectation(s) specified in the intent. + +The attribute corresponding to intent reporting in the intent model can be configured to choose from these options. This will be discussed further in detail during the intent modelling in the subsequent normative work. +- Fulfilment: if the intent is provided to the RMIH for fulfilment, it means that RMIH starts taking necessary actions (e.g., allocating resources) and actual changes in the network and/or the system can be observed. + +## 4.2 Intents management in current industry landscape + +### 4.2.1 Intent-driven Management in TMF + +The work on intent-based operation at TM Forum is done under the Autonomous Networks Project (ANP) and specified in the set of specifications, with IG1253 [i.7] and TR290 [i.8] being the central ones for the intent concept and intent expression models. The intent specification work is embedded in the Autonomous Network Reference Architecture [i.10]. + +The ANP develops specifications for various aspects of autonomous networks including its generic architecture, the definition, and assessment of levels of autonomy and closed loop management. Intent is a particular focus with specifications about: + +- The definition of intent +- The architecture of intent-based networks with intent management functions +- An API for life cycle management of intents, reporting, and requirement negotiation +- The intent expression model in the form of the TM Forum Intent Ontology (TIO) +- Capability exposure and discovery of intent management functions. + +The scope of the work is not limited to a single operational domain. It rather introduces concepts that would be applicable vertically in multiple operational layers as well as horizontally across multiple domains. The API as well as the model for intent expressions are designed to adapt to domain specific use cases while maintaining a generic core model. + +Although the models are different, the proposed O-RAN intent definitions in this study are similar and compatible to other SDOs, such as TMForum and 3GPP. + +Intents are declarative. They specify “what” is reached, but not “how” to reach it leaving the intent handlers with full autonomy to handle them. Therefore, any explicit instructions of what to execute is excluded from being specified within intent or by the intent API. Both are rather concerned with the definition, distribution, and management of requirements enabling subsystems to make suitable decisions and find solutions on their own rather than being instructed what actions to take. This way of interaction between subsystems enhances separation of concerns which is advantageous for AI-native implementations. + +#### Intent modeling + +Intent is a knowledge object expressing requirements. Sending an intent therefore means informing the receiving system about a set of requirements it needs to comply to. When the requirements in the intent are not needed anymore then they are removed. This means intent objects are actively lifecycle managed and need to be fulfilled, as long as the requirements they relayed are needed. The TM Forum intent API TMF921[i.9] is therefore primarily concerned with executing the lifecycle management of intent knowledge objects. + +The TM Forum intent ontology (TIO) is the model for intent expression. It is based on the Resource Descriptor Framework (RDF) standard by W3C. It was chosen due to its capabilities and track record for knowledge modeling applications, since RDF is used in native machine reasoning implementations provided by different opensource solutions. Intent instances are a subgraph within the ontology and therefore anchored with full semantical context. Logical reasoning about the requirements is directly supported by this approach. + +The intent ontology model proposed by TM Forum is highly modular. The ontology used for intent expression within a domain is a federation of a common generic model referred to as intent common model and domain-specific additions referred to as intent extension models. The intent common model is specified in TM Forum (TR290) [i.8], with a simple common structure that defines the internal structure of intent objects and provides general purpose vocabulary for expression of requirements. Other SDOs are invited to leverage the common intent model and then develop their own intent extension models for their scope of expertise (e.g., specific extensions to RAN management intents in O-RAN). No central or formal governance is required for intent extension models. The goal of the model federation is to keep intent expressions consistent across domains (business, management, traffic, etc.), while still being able to easily adapt it to new domain specific needs. + +#### Intent API + +The TM Forum intent API is designed as polymorphic API with two-tiered information models. It mainly defines generic life-cycle management operations of intent objects and intent reports. This makes the API applicable whenever intent based operation is needed, irrespective of the domain or reference point. The API adapts its information model using the same federation mechanism described above. The stage 3 API work is published as TM Forum Open APIs and it is based on REST. The intent encoding follows established standards, with support of JSON-LD, XML/RDF, and Turtle formats. + +#### Architectural aspects and definitions + +TM Forum ANP introduces intent managers [i.7]. They constitute functional blocks present in all sub-systems that interact using intents. If two systems or domains interact using intents, it is their intent managers that are directly interacting over the intent API. In this respect, the introduction of intent-based operation means allocation of intent managers in the target architecture. + +The implementation of intent managers in various domains can vary significantly with respect to complexity and capability. Any function or component within an architecture that implements the intent API and therefore participates in intent life-cycle management and intent reporting classifies to be an intent manager. + +Within a domain or sub-system, an intent manager initiates and coordinates the assurance of requirements received within intents. Consequently, an intent manager interacts with other management functions using their exposed APIs and management services as part of its intent requirement assurance. + +TM Forum ANP defines two roles intent managers can take in the life cycle of intent: + +- Intent Owner: The intent manager that creates a requirement another system or domain will fulfill is referred to as intent owner. In this respect an intent owner is the source of intents. +- Intent Handler: The intent manager that receives an intent and is obliged to fulfill it is referred to as intent handler. + +Intent owner and intent handler are roles an intent manager would take within the life cycle of a particular intent. In this respect an intent object has exactly one owner and one handler. If considering the intent API being a management service, the MnS producer would be associated with the intent handler role, while an intent owner would be an MnS consumer. However, the TM Forum defined roles of Intent Owner and Handler imply further responsibilities and authorization in the intent life cycle. For example, only an intent owner can modify or delete the intent it has issued. An intent handler cannot change the intent objects, but it can report to the owner about its state and success in fulfilling the requirements. + +Intent managers publish their capabilities. This includes their support for optional operations on the intent API and most importantly they specify which intent extension models they supports. The capability profile also determines the scope of responsibility of an intent manager. Tying it to domains in the architecture, network topology or sets/types of resources. This allows other intent managers to detect them as suitable destination of their requirements, but it also determines what vocabulary and semantics is available for formulating intent. + +### 4.2.2 Intent-driven Management in 3GPP + +#### Introduction + +The work on intent-driven management in 3GPP SA5 is specified in the technical specification (TS) 28.312 [i.6] and in the technical report (TR) 28.912 [i.5]. + +An intent specifies the expectations including requirements, goals, and constraints for a specific service or network management workflow. The intent may provide additional information on particular objective(s) and possibly some related details. SA5 defines four general concepts related to intent: + +- An intent is understandable by humans, and also needs to be interpreted by the machine without any ambiguity. +- An intent focuses more on describing “what” needs to be achieved and not “how” to achieve them. +- The expectations specified in an intent are agnostic to the underlying implementation within the scope of a 3GPP system. +- An intent need to be quantifiable from network data so that the fulfilment result can be measured and evaluated. + +#### Intent Driven Management Service + +Complying with the service-based architecture of 5G, an intent-driven management system is proposed to consist of three basic components: (i) an intent-driven management service, (ii) producer of the service, and (iii) consumer of the service. In an intent-driven management system, the consumer provides its intent to the producer of a set of management services (MnS) that would be consumed in a specific domain. The difference between an intent-driven + +management approach and a non-intent-driven one can be explained with the following example. For the purpose of requesting a radio network with a new coverage, in a non-intent-driven approach, the set of non-intent-based MnSs (e.g., provisioning MnS) is used to decommission a cell and instantiate the cell to a new Node B for the new coverage. However, in an intent-driven approach, the intent-related MnS produced by the domain is used. Based on the intent, the system can trigger actions (e.g., decommission a cell and instantiate the cell to a new Node B) to satisfy received intent. The Intent-driven MnS could in principle be deployed as a replacement of the deployed non-intent-based MnSs for the same network and service management purpose, where the consumer focuses on the 'what' and the producer is concerned about the 'how'. + +A 3GPP intent driven MnS allows for the following between its consumers and producers, as defined in 3GPP Rel-17 TS 28.312 [i.6]. + +- Its MnS Consumer to: + - express intents for managing networks and network services + - to obtain feedback on intent evaluation result + - to modify intents +- Its MnS Producer to provide the following capabilities: + - validate the intent + - translate the received intent to executable actions by: + - Performing service or network management tasks. + - Identifying, formulating, and activating service or network management policies. + - evaluate the result/information about the intent fulfilment (e.g., the intent is initially satisfied or not) and intent assurance (e.g., the intent is continuously satisfied). + +Further enhancements are proposed for Rel-18 in study TR 28.912 [i.5], including: + +- intent reporting to provide detailed reporting on intent fulfilment +- capability management to allow MnS Producers to expose their intent handling capabilities to MnS Consumers + +#### Workflow + +The workflow of an intent-driven MnS consists of the following steps: + +- The consumer states the intent which is to be fulfilled. +- The producer validates the intent and translates it to identify the required internal logic. +- The producer executes the compiled logic to fulfil the intent. +- The producer may report about the fulfilment result of the intent. + +The intents can be fulfilled by the intent-driven MnS producer using mechanisms including among others: rule-based mechanism, closed loop, and AI/ML based mechanisms. Different kinds of intents are applicable for different kinds of standardized interfaces. Based on roles related to 5G networks and network slicing management, following categories of intents may exist: + +- Intent from communication service customer (Intent-CSC) +- Intent from communication service provider (Intent-CSP) +- Intent from network operator (Intent-NOP) + +#### Intent Model + +The Intent Information Object Class (IOC) allows MnS Consumers to manage intent expectations towards MnS Producers. Generally, a consumer may use an intent to express to the producer the need for: “an object O with characteristics S”. The characteristics S reflects the requirements, goals, and contexts for an object. The object may be a 3GPP managed object like a network slice, subnetwork (e.g., radio network) or other objects like a service. The consumer may specify the same characteristics, S, for multiple objects within a single intent. Accordingly, an intent contains one or more intent expectations, each of which specifies requirements on one object or on multiple objects of the same type. + +For a given intent expectation, the desired characteristics of the object(s) are the expectation targets to be achieved. The expectation targets can include the metrics that characterize the performance of the object(s) or some abstract index that expresses the behavior of the object(s). Each expectation target may be constrained to only be achieved for a very specific set of conditions as context. The context describes a set of conditions and constraints to trigger corresponding management tasks to achieve the expectation targets. For example, the consumer may state that: "ensure that *handoverFailureRate* < 2 % if Load > 80 %", where the expectation target (*handoverFailureRate* < 2 %) is to be achieved only in the context (Load > 80 %). In this example, the producer will perform handover tasks to achieve the expectation target *handoverFailureRate* < 2 % when they observe the context "Load > 80 %". The object (s) for which a given expectation is addressed can be expressed with the expectation object's identifier. + +#### Intent Life Cycle Management + +An Intent driven MnS includes the management capabilities to support intent lifecycle management, e.g., create an intent, read an intent, update an intent, delete an intent. + +#### Intent Driven MnS Scenarios + +3GPP Rel-17 TS 28.312 [i.6] defines the following scenarios and use cases related to RAN: + +- Intent containing an expectation for delivering radio network +- Intent containing an expectation for delivering a radio service +- Intent containing an expectation for delivering a service +- Intent containing an expectation on coverage performance to be assured +- Intent containing an expectation on RAN UE throughput performance to be assured. + +Further work in 3GPP Rel-18 TR 28.912 [i.5] proposes enhancements, including: + +- Intent Capabilities Handling +- Intent Reporting +- Intent fulfilment feasibility check +- Intent driven approach for radio capacity assurance +- Intent driven approach for RAN energy saving +- Intent driven approach for 5GC management, specifically 5GC network delivering. + +# --- 5 SMO Intent driven management Use Cases + +## 5.1 Overview + +The SMO contributes to the autonomous network management in OSS by supporting intent-driven management for a subset of the RAN management features. This chapter describes the RAN management use cases where intent-driven management is used. + +The actors used across the different RAN Intents-driven management use cases are: + +| Actor/Role | Description | +|--------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| RAN Management Intent Owner (RMIO) | An authorized SMO service consumer, responsible for formulating the RAN management Intents as per its own goals and requirements and consuming intent-based services.
NOTE: the actual owner of the intent might have own management architecture behind the RMIO which is interacting with the SMO. | +| RAN Management Intent Handler (RMIH) | An authorized SMO service producer which understands, can process and ensure fulfilment of RAN management Intents. | +| SMO | RAN Service Management and Orchestration system that offers, among other services, the RAN Intent-driven management services. | +| SME | Service defined in non-RT RIC architecture [i.3], enhanced with support for invocation, registration, and discovery services for the capabilities of the RMIHs. | + +**Table 5.1-1: Actors used across the different RAN Intents-driven management use cases** + +## 5.2 Use Case: External exposure of RAN Intent-driven management services + +An SMO consumer (e.g., an E2E management system, a BSS, etc.) needs to set a RAN management Intent. In order to discover what RAN management Intents are supported by a certain SMO, the SMO consumer can inquire about the RAN Intent handling capabilities offered by an SMO, before it decides which RAN management Intent it will formulate and set with that SMO. + +The SMO needs to support capabilities for the registration and discovery of the RMIHs. This can be a natural add-on to the Service Management and Exposure (SME) in the SMO, where enhancements to the SME services would accommodate the registration and discovery of information specific to the RMIHs capabilities. + +The RMIHs can register information about the Intent Driven Objects they support, and the intent management operations supported, their own addressing/reachability information, and possibly other information of use for the SMO consumers. + +The RAN management Intent requests received by the SMO can be handled via the SME's service invocation capabilities, which can also authorize the requests before routing them to the right RMIH (i.e., with the capability to handle the given RAN management Intent). + +NOTE: There can be alternative flows, these are not analyzed in the present document. + +### 5.2.1 Use Case flow: RAN management Intents capabilities discovery + +| Use Case Step | Description of the Step | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | SMO exposure of the capabilities for RAN management Intent services to external SMO consumers (e.g., an E2E management system, a BSS, etc.). | +| Actors and Roles | RMIO
RMIH
SMO
SME | +| Assumptions | SMO has the SME services that support capabilities for RAN management Intents. | +| Pre-conditions | The SMO consumer is an authorized consumer of the SMO services.
RMIHs have registered their service capabilities with the SME, see use case 5.2.3. | +| Begins when | The SMO consumer (E2E management system, BSS, etc.) wants to set a RAN management Intent and needs to discover the matching capabilities supported by the SMO before deciding which RAN management Intent it will set.
The SME receives the discovery request for the RAN Management Intent capabilities supported in the SMO, with criteria set for available RAN management intents models. | +| Step 1 (M) | The SME queries its RAN management Intents capability registry using the query criteria and finds three RAN Intent Driven Objects related to RAN management intents that are supported by a RMIH. | +| Step 2 (M) | The SME returns the matches to the SMO consumer that initiated the intents capabilities discovery. | +| Ends when | The SMO consumer discovered the RAN management Intent capabilities supported in the SMO that are related to RAN management intents. | +| Exceptions | None | +| Post Conditions | The SMO consumer obtained the list of RAN management Intent capabilities supported by the SMO. | + +**Table 5.2.1-1: RAN management Intent discovery by external SMO consumers** + +### 5.2.2 Use Case flow: Handling of external RAN management Intents requests + +| Use Case Step | Description of the Step | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | SMO exposure of the RAN management Intent services to external SMO consumers (e.g., an E2E management system, a BSS, etc). | +| Actors and Roles | RMIO
RMIH
SMO
SME | +| Assumptions | SMO has the SME services that support capabilities for RAN management Intents. | +| Pre-conditions | The SMO consumer (E2E management system, BSS, etc) has discovered RAN management intents capabilities supported by the SMO, as per use case 5.2.1 and has decided which RAN management Intent it will set in the SMO.
The RAN management Intent that the SMO consumer wants to set is supported by the SMO.
The SMO consumer is an authorized consumer of the SMO services. | +| Begins when | The SMO consumer acts as an RMIO and initiates a request to set a RAN management intent in the SMO (example: performance assurance expectations for a group of cells from a certain site). | +| Step 1 (M) | The SME receives the RAN Intent-driven management request and starts processing the service invocation request. | +| Step 2 (O) | The SME can perform the authorization procedure.
As example, if OAuth is used, the SME returns the authorization token to the SMO consumer, with the token scope set to allow access to the RAN management Intents related services. | +| Step 3 (M) | The SME queries its RAN Intents capability registry and finds a RMIH in SMO which has the capability and responsibility to process the received Intent. The SME forwards the RAN management Intent set request to the appropriate RMIH. | +| Ends when | The RMIH received the RAN management Intent capabilities supported in the SMO that are related to RAN performance assurance intents for a group of cells. | +| Exceptions | None | +| Post Conditions | N/A | + +**Table 5.2.2-1: RAN management Intent service invocation handling by SME** + +### 5.2.3 Use Case flow: RAN management Intents capabilities registration + +| Use Case Step | Description of the Step | +|------------------|------------------------------------------------------------------------------------------------------------------------------| +| Goal | SMO handling of registration for the RMIH capabilities (including their domain responsibilities). | +| Actors and Roles | RMIH
SMO
SME. | +| Assumptions | SMO has the SME services that support capabilities for RAN management Intents.
At least one RMIH is available in the SMO. | +| Pre-conditions | The RMIH is installed and running. | +| Begins when | The RMIH has submitted a request to register its RAN management Intent handling capabilities to the SME. | +| Step 1 (M) | The SME adds the received registration information into the RAN Intents capability registry. | +| Ends when | The RMIH capabilities are successfully registered by the SME into the RAN Intents capability registry. | +| Exceptions | None | +| Post Conditions | N/A | + +**Table 5.2.3-1: RMIH capabilities registration with SME** + +## 5.3 Use Case: Intent-driven management of RAN performance assurance + +An SMO consumer (e.g., an E2E management system, a BSS, etc) needs several O-RAN NFs with some specific performance assurance targets. The SMO consumer has the capability to formulate the RAN management requests using intents hence it plays the role of the RAN Management Intent Owner (RMIO). The RMIO also wants to receive reports on the status and fulfilment of the intent with a given scope, frequency of reporting and once certain milestones were reached, or events were observed. + +Some examples of the RAN management intent requirements for the performance assurance service levels of O-RAN NF instances are: + +- the service availability requirements (e.g., redundancy level, acceptable maximum time of service interruption, etc) to be provided, +- maximum number of UEs to be supported, +- desired coverage area or geographical regional area, +- an URLLC profile and any specific characteristics, +- granularity and specific events for the reporting, and others. + +The performance assurance requirements for the desired O-RAN NFs instances, as well as the intent reporting expectations, are expressed as expectations by the RMIO and are then sent to the SMO. Assuming that the SMO receiving the RAN management Intent has also the capability to process it, then the SMO acts from here on in a RAN Management Intent Handler (RMIH) role. The RMIH automates management in the SMO and for that purpose it consumes the SMOSs available in the SMO. + +The RMIH extracts the different expectations from the received intent and decomposes them into various actions for the SMO. The RMIH needs to translate the received intent expectations into known RAN PM, KPIs, CM for the O-RAN NFs, and then determines if a set of O-RAN NFs consisting of the O-RAN NFs with the characteristics and performance profiles identified does already exist. + +If a set of O-RAN NFs instances with the desired performance assurance profile does not exist, or if it exists but its cloudified NF resources are at capacity so they cannot be shared with another SMO consumer, the RMIH can determine that new O-RAN NFs instances need to be created. In that case, the O-RAN NFs instances are identified, with their appropriate flavors and profiles to match the assurance requirements derived from the intent. For simplification purposes, it is assumed in this use case that the O-RUs are available and only the cloudified NFs are subjected to the intent request. The RMIH triggers and coordinates the appropriate actions within SMO, to achieve the creation of the set of O-RAN NF instances with the appropriate characteristics and performance that matches the expectations of the RAN management Intent. The RMIH continues to monitor the NFs instances throughout its lifetime (i.e., until that RAN management Intent is terminated), and takes during this time any necessary actions (CM, LCM, etc) to maintain the O-RAN NFs instances performance at a level that meets the Intent expectations. + +The RMIH also provides the reporting on the status and fulfilment of the received RAN management Intent according to the reporting expectations of that Intent. + +### 5.3.1 Use Case flow: Intent-driven management of RAN performance assurance + +| Use Case Step | Description of the Step | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | A set of O-RAN NFs instances with given performance expectations can be provided, and sustained, by the SMO based on a RAN management Intent received from a SMO consumer. | +| Actors and Roles | RMIO.
RMIH.
SMO. | +| Assumptions |
  • - SMO has the RMIH capabilities to handle the RAN management Intent for a set of O-RAN NFs instances performance assurance.
  • - The RAN network is assumed to have sufficient coverage and there is no need to install new O-RUs for the area targeted by the intent.
  • - The different types of service profiles are provisioned in SMO, including the type URLLC used in this use case.
| +| Pre-conditions |
  • - The SMO consumer (E2E management system, BSS, etc) identified the need for a gset of O-RAN NFs instances with given characteristics and performance levels.
  • - The SMO consumer has the capabilities to formulate and use a RAN management Intent, hence can act in the role of the RMIO.
  • - The SMO consumer (RMIO) was authorized to access the SMO services for RAN management Intents. The Use Case from clause 5.2 was executed and SMO routed the request to the RMIH that is capable to handle the RAN management Intent.
  • - The SMO consumer (RMIO) has used the intent manager capabilities exposed by the SMO and has found that the SMO has RMIH capable to handle an intent that the RMIO wants to set.
| +| Begins when | The RMIH receives the request to set a RAN management Intent that contains expectations on characteristics and performance assurance expectations for the set of O-RAN NFs instances, as well as the reporting expectations on the outcome and fulfilment of the Intent. | +| Step 1 (M) | RMIO sets a RAN management Intent to the SMO, that contains expectations on the set of O-RAN NFs instances with specific characteristics and performance levels and expects them to be assured by the SMO. | +| Step 2 (M) |

The SMO processes the RAN management request received, and further acts in the RMIH role. This step can consist in several sub-steps, to handle the Intent decomposition and translation of the given Intent expectations into appropriate O-RAN NFs and each of their PM, CM, KPIs, and/or specific characteristics to match the given expectations. There can be different services that need to be invoked within the SMO in order to realize the use case.

Note: the RMIH logic for this step can be done in various ways, ranging from more elaborate use of machine reasoning and AI/ML technologies to simpler approaches using policy-based decision making. As this is subject to implementation choices, it is not elaborated in the present document.

| +| Step 3 (M) | The RMIH initiates the actuation of the identified actions by making use of the respective SMO services. These can range from requesting O-RAN NF instantiations using O2, to their configurations over O1. | +| Step 4 (M) | The RMIH provides any needed intent reporting on the outcome and status of the Intent, in accordance with the intent reporting expectations received from the RMIO. | +| Step 5 (M) |

The RMIH continuously observes, evaluates, decides and actuates any required management actions with other SMO functions in order to provide the performance assurance of the set of O-RAN NFs instances per expectations.

Hence the RMIH initiates the necessary monitoring actions (e.g., PM, FM) to be able to evaluate at all times the level of fulfilment of the Intent, by consuming the appropriate SMOs.

| +| Step 6 (M) | In case any of the received PM, FM are evaluated by the RMIH to be in a breach the performance assurance expectations for the set of O-RAN NFs instances, the RMIH assesses and takes the necessary actions to rectify the situation, and to bring back the performance of the respective O-RAN NF/s at the required level/s. | +| Step 7 (M) | The RMIH provides the intent reporting on the status of the Intent, in accordance with the intent reporting expectations received from the RMIO (e.g., when a certain event occurs, regular status reporting, when certain thresholds are met, etc). | +| Ends when | The RMIO requests the termination of this RAN management Intent. | +| Exceptions | None in the present document | +| Post Conditions | N/A | + +**Table 5.3.1-1: RAN management Intent for performance assurance of a set of O-RAN NFs instances** + +## 5.4 Use Case: intent deadline + +As discussed in Clause 4.1.1, an RMIO can provide an intent either for exploration purposes or for fulfilment purposes. However, for both cases, the RMIO may want to obtain the results (sent by the RMIH via intent reports) within a certain timeframe. If the RMIO does not get the results within that timeframe, the intent may not remain of interest to the RMIO anymore and therefore removed. This information can be conveyed to the RMIH, as an intent attribute, referred to as “intent termination deadline”. + +When the RMIO provides the intent to the RMIH, the corresponding deadline can be modelled within the intent itself. There are different ways the RMIO can specify the termination deadline. For example, it can be specified in a datetime format (e.g., DD-MM-YYYY hh:mm:ss). Alternatively, it can be set as a value to a timer that starts as soon as the RMIH receives the intent. + +When the deadline is passed (or the timer expired), regardless of the state/status of the intent, the RMIH removes the intent from the system and sends a report about it to the RMIO. + +### 5.4.1 Use Case Flow: intent deadline + +| Use Case Step | Description of the Step | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | RMIO wants to obtain the result for handling an intent within a certain timeframe. | +| Actors and Roles | RMIO
RMIH
SMO | +| Assumptions | SMO exposes its capability for RAN management intents through the SME.
At least one RMIH is available in the SMO. | +| Pre-conditions | The RMIO is an authorized consumer of the SMO services.
The RMIO can specify an intent to be handled. | +| Begins when | The RMIO has decided to obtain the result of handling an intent within a timeframe. | +| Step 1 (M) | The RMIO provides an intent to the SMO. | +| Step 2 (M) | The SMO routes the request to the right RMIH, as per use case 5.2.2. “Use Case flow: Handling of external RAN management intents requests”. | +| Step 3 (M) | The RMIH considers the intent and starts the necessary actions to handle the intent. | +| Step 4 (M) | The RMIH starts sending intent reports within the specified timeframe. | +| Ends when |
  • The intent is already handled by the RMIH (for fulfilment or for exploration).
  • The specified timeframe already passed.
| +| Post Conditions | The RMIH removes the intent from the system. | + +**Table 5.4.1-1: Intent Deadline flow** + +# 6 Procedures for Intent-driven management + +## 6.1 Overview + +This clause describes the procedures for intent-driven management. + +## 6.2 Removal of intent + +An SMO consumer (e.g., an E2E management system, a BSS, etc.) has previously provided an intent containing its requirements to the RMIH within the SMO. Consequently, the SMO consumer took the role of RMIO for this intent. + +If for some reason, the RMIO has decided that it does not need the requirements anymore, which were previously expressed and issued within the intent. the RMIO requests the RMIH for a removal of the intent. + +On reception of the intent removal request, the RMIH within the SMO stops considering the intent in its intent assurance activities. Furthermore, it performs potentially needed cleanup actions before removing the intent. + +The removal of the intent by the RMIH within the SMO is acknowledged by sending a final intent report to the RMIO by the RMIH. + +### 6.2.1 Remove Intent + +| Use Case Step | Description of the Step | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | RMIH retires the intent, i.e., stops considering the intent requirements in network operations. | +| Actors and Roles | RMIO
RMIH
SMO | +| Assumptions | - | +| Pre-conditions | The RMIO has previously provided the intent to the RMIH within the SMO. | +| Begins when | The RMIO decides that all expectations in the previously provided intent are not required any more. | +| Step 1 (M) | The RMIO requests a removal for this intent from the RMIH. | +| Step 2 (M) | The RMIH on reception of the remove request stops considering all expectations from this intent in a graceful way in its intent assurance. | +| Step 3 (M) | The RMIH issues a final intent report to the RMIO about the status of the intent removal. | +| Ends when | The RMIO received the final intent report about the removed intent. | +| Exceptions | None | +| Post Conditions | N/A | + +**Table 6.2.1-1: Remove Intent flow** + +## 6.3 Assessment of the potential fulfilment and outcome of an intent + +An RMIO can explore what intent requirements and constraints are feasible. This means, the RMIO can explore if and to what extent an RMIH can realistically fulfill the intent. For an intent being explored RMIH is not required to fulfill the intent but assess if it would be able to do so and what level of fulfillment it could reach. The results of this assessment are reported to the RMIO. + +Providing an intent without requiring fulfillment, but rather asking for hypothetical assessment of possible fulfillment is also referred to as intent probing. To distinguish what the intent is provided for, the term “provided for exploration” is used for potential fulfillment assessment, while the term “provided for operation” is used if an RMIH is asked to fulfill the intent. The term “providing an intent” refers to both without distinguishing if operation or exploration is wanted. + +An RMIO provides an intent for exploration to an RMIH expecting a report about the estimated outcome of that intent, without the RMIH being required to actually take actions in the network that would fulfill the intent. After receiving an intent for evaluation, the RMIH begins to generate intent reports according to report subscription. These reports contain an estimated outcome for the provided intent. These reports would resemble intent reporting an RMIH would generate for this intent if it were provided for operation and would need to be fulfilled. Through the series of intent reports an RMIH can communicate potential outcomes to the RMIO. + +This use case allows the exploration of multiple options and a continuous observation of the RMIH and its estimated intent fulfillment over time. An RMIO can observe the potential intent fulfillment an RMIH is capable of and use this information in its own decisions. In particular, the RMIO can decide what requirements to include in an intent it would provide for operation. + +An intent provided for exploration is actively managed through its life cycle by the RMIO. The intent being explored can be updated on request by the RMIO. The sending of reports by the RMIH according to report subscription continues until removal of the intent is requested by the RMIO. + +### 6.3.1 Probing the outcome of an intent + +| Use Case Step | Description of the Step | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | RMIO wants to explore if a particular set of requirements and constraints can be fulfilled by the RMIH. | +| Actors and Roles | RMIO
RMIH
SMO | +| Assumptions | SMO exposes its capability for RAN management intents through the SME.
At least one RMIH is available in the SMO. | +| Pre-conditions | RMIO has discovered capability for RAN management intent supported by SMO, as per use case 5.2.1 “Use Case flow: RAN management intents capabilities discovery”.
The RAN management intent that the RMIO wants to provide for exploration is supported by an RMIH within the SMO.
The RMIO is an authorized consumer of the SMO services. | +| Begins when | The RMIO has decided which RAN management intent it needs to explore with an RMIH. | +| Step 1 (M) | The RMIO provides an intent to the SMO for exploration. | +| Step 2 (M) | The SMO routes the request to the right RMIH, as per use case 5.2.2. “Use Case flow: Handling of external RAN management intents requests”. | +| Step 3 (M) | The RMIH considers the intent and starts the assessment of the expected outcome in case the intent became an actual requirement that needs to be fulfilled. | +| Step 4 (M) | The RMIH starts sending intent reports with the expected outcomes following the reporting expectations set in the intent being probed. | +| Step 5 (O) | The RMIO requests an update of the intent. The RMIH will provide further reports considering the updated requirements. | +| Ends when | The RMIO requests the removal the intent being assessed by the RMIH, following same steps as for intent removal described in use case 5.4. | +| Exceptions | None | +| Post Conditions | N/A | + +**Table 6.3.1-1: Probing for the potential fulfilment of an intent** + +### 6.3.2 Modify the intent probing + +The RMIO performs lifecycle management of the intent being explored, in a similar manner to any regular intent. The RMIO can modify the intent, setting new expectations, and/or exploring different combinations of requirements. This would be performed following the same steps as in use case 5.8). + +## 6.4 Preferences on possible options for intents outcome + +In some cases, an RMIH may find different alternative options to fulfil an intent. One of the alternatives can be better or more optimized in one aspect (with respect to some expectations within the intent) and other alternatives can be better in another aspect (with respect to other expectations). In other cases, an RMIH is not able to find any option capable to fulfil all the intent expectations but there can be some alternatives that achieve better results for certain expectation(s) compared to others. + +In both situations described above the RMIH has the domain knowledge to find the alternative solutions and it has the autonomy to decide on the solution to be employed to fulfil intent expectations. However, if suitable solutions are different in the outcome, the RMIH might not have sufficient information, which can be deducted from the intent to make an optimal decision. The RMIH does (and should not) not have the domain knowledge of the RMIO’s domain where the intent and its requirements originate from. Only the RMIO understands if and why a particular outcome achieved by the RMIH is preferred or not. In some cases, it can therefore be beneficial that the RMIH and RMIO engage in a collaborative assessment of the alternative solutions. An RMIH seeking evaluation of the alternative + +solutions is referred to as a “request for judgement” and a reply from the RMIO that contains the respective assessment of the presented alternatives is referred to as “providing of preferences”. + +This enables the RMIH to seek support in its decision making from the RMIO. The potential outcomes are represented by intent reports. This means the RMIH asks for judgement from the RMIO regarding which intent report the RMIO would consider to be most preferable. + +The use of intent reports to represent the potential effect of a solution considered by the RMIH allows seeking judgement from the RMIO without revealing details about the solution. The RMIO does not have the domain knowledge to understand the solution as applied in the RMIH’s domain, but it is able to understand and evaluate the outcome for requirements it has provided itself. Intent reports are a representation of outcomes the RMIH would be able to generate, and the RMIO would be able to evaluate. This mechanism avoids the disclosure of detailed domain information in both directions. It avoids, that details about the reason for intent requirements would be disclosed to the RMIH, and it avoids, that the details of the solution and its implementation in the RMIH’s domain are disclosed to the RMIO. This means this use case allows collaborative evaluation of solutions, while preserving the fundamental separation of concerns between RMIO and RMIH. + +On reception of the intent reports to be judged, the RMIO assesses its preferences and provides them to the RMIH. The preferences would be provided by the RMIO through an intent update. This means, the preference information regarding a specific judgement request is added to the intent. + +The RMIO can provide its preference in several ways . For example, the RMIO can provide its preference by stating which report the RMIO prefers the most. Or, the RMIO can rank the received reports from the most preferred to least preferred. Furthermore, the RMIO can present a quantitative assessment by providing a preference score for each judged outcome. + +On receiving the modified intent from the RMIO containing preferences, the RMIH maps them back to the investigated solutions and decides which to implement. + +### 6.4.1 RMIO preferences for one of the offered intent options + +| Use Case Step | Description of the Step | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | RMIH wants to collaboratively evaluate which is the preferred solution among different alternatives that it can offer to the RMIO. | +| Actors and Roles | RMIO
RMIH
SMO
SME according to [i.4] | +| Assumptions | SMO exposes its capability for RAN management intents through the SME.
At least one RMIH is available in the SMO.
SME in SMO has awareness of the RMIO capabilities with respect to supporting requests for collaborative assessment of solutions. | +| Pre-conditions | The RMIO has provided an intent to the RMIH.
If the RMIO supports the capabilities to receive a judgement request and to express its preferences in a collaborative exchange with an RMIH.
Editor's Note: the registration of RMIO capabilities needs to be added under the intent capabilities registration use case. | +| Begins when | The RMIH found a set of potential solution alternatives that would produce different outcomes regarding an intent. The RMIH decides to request the preferences on these intent outcome alternatives from RMIO's perspective. | +| Step 1 (M) | RMIH discovers the RMIO's capabilities as described in use case 5.2.3 and determines that it has the capability to receive judgement requests and express its preferences.
NOTE: the discovery of RMIO capabilities can be added under the intent capabilities discovery use case. | +| Step 2 (M) | The RMIH asks the RMIO for its preferences on a set of potential intent outcomes. The preferences are requested by the RMIH sending multiple intent reports (as described in use case 5.7. "Requesting intent reports and intent report generation"). Each intent report is representing the expected outcomes of an investigated solution. | +| Step 3 (M) | The RMIO considers the set of intent reports and determines its preferences on the presented outcomes, according to its own criteria. | +| Step 4 (M) | The RMIO provides its preferences containing the order of preference for the presented outcomes. | +| Step 5 (M) | The RMIH considers the preferences provided by the RMIO and uses the most preferred. | +| Ends when | The RMIH applies the previously investigated solution towards achieving the preferred intent outcome as expressed by the RMIO. | +| Exceptions | None | +| Post Conditions | N/A | + +**Table 6.4.1-1: Preferences regarding the possible outcome options for intents** + +## 6.5 Requesting intent reports and intent report generation + +An RMIO can stay informed about the compliance of the network to intent through intent reports. An intent report is a data object created by an RMIH. It contains information about overall compliance of the SMO to an intent. It can furthermore contain detailed information about the status of individual expectations and the fulfilment and/or assurance conditions including e.g., observed state, and KPI values at the time of report generation. + +The RMIO includes intent reporting requirements in the intent expression. These include information about events and conditions for intent report generation by the RMIH. If such an event occurs or condition is met, the RMIH will generate an intent report and sends a notification to the RMIO. + +Events for intent report generation capture significant milestones in intent handling and events in intent lifecycle management. These can include for example, the decision to accept and reject intent or intent modifications, the transition of the network from being compliant to being degraded and vice versa, or the termination of intent. Furthermore, it is possible to request and generate intent reports periodically and with timing specified by RMIO. The complete list of events and milestones available for intent report requests will be determined in the normative phase. + +The requirements for intent reports also allow the RMIO to refine the scope of reporting. This refers to the information that is expected to be included in an intent report. It is possible to define multiple requirements for intent reporting for + +the same intent. This allows the RMIO to receive notification about intent reports for the same intent but for different cases in which report generating events, conditions, and scope were different. An intent report contains references to the information in the intent about which it is reporting. Furthermore, it includes information on the SMO fulfillment of the intent overall and about each individual fulfillment of each requirement. + +An intent report refers to the intent it is generated for using the unique identifier of the intent known by RMIO and RMIH. + +The intent report may contain the timestamp of report generation and a unique identifier/sequence number for the report. + +The intent report allows the RMIH to include additional information such as reasons behind certain actions in the intent report. For example, their provided reason can state why an intent was rejected or what caused the non-fulfilment. In the successful case, it includes fulfilment information per intent reporting request. + +This use case introduces intent report sending through a notification mechanism. Whenever an intent report is ready, the RMIH sends a notification to RMIO that the intent report is ready for collection. + +### 6.5.1 Requesting intent reports and intent report generation + +| Use Case Step | Description of the Step | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | RMIO wants to be informed with an intent report about status of the intent request processing by the RMIH, in accordance to the report scoping stated in the intent | +| Actors and Roles | RMIO
RMIH
SMO
SME | +| Assumptions | -The RMIO is an authorized SMO consumer for intents.
- SMO has the SME services that support capabilities for RAN management Intents.
- SMO exposes capabilities to handle RAN management intents via its available RMIHs | +| Pre-conditions | - The RMIO has decided which detailed requirements to include in the intent to be sent to SMO, including the reporting requirements. The RMIO has provided an intent to the RMIH that was available in the SMO. | +| Begins when | The RMIH successfully accepted the intent, and the intent is under fulfilment. | +| Step 1 (M) | The RMIH monitors the conditions for intent report generation as stated in the intent reporting requirements. | +| Step 2 (M) | Once intent report generation conditions are met, the RMIH generates the report(s) according to the requirements. | +| Step 3 (M) | The RMIH sends a notification that an intent report has been generated and available to be collected by the RMIO. | +| Step 4 (M) | The RMIH continues to determine throughout the intent handling process when intent reports need to be sent to the RMIO, by repeating steps 1, 2 and 3. | +| Ends when | The intent is removed or when the intent reporting requirements are removed. | +| Exceptions | None | +| Post Conditions | N/A | + +**Table 6.5.1-1: Requesting intent reports and the intent report generation** + +## 6.6 Modification of requirements in an intent + +The RMIO, which previously provided an intent containing its requirements, can modify the requirements within any existing intents that it owns. This use case can be used for example if the RMIO wants to set new target KPIs for performance requirements, change the intent reporting periodicity or rate, or change any service delivery requirements, etc. + +The RMIO is the only actor allowed to modify an existing intent. The RMIH within the SMO cannot modify existing intent requirements after they have been accepted, but it is responsible for keeping the RMIO updated about the intent fulfilment state and progress through intent reports as required by the RMIO. + +The intent to be modified is referred to in the modification request by its unique identity known to RMIH and RMIO. + +The RMIH can accept or reject the intent modification request. The acceptance or rejection of the requirements modification in an intent is reported by the RMIH. If the intent modification request is rejected, a rejection reason will be provided by the RMIH, and the original intent will remain unchanged. Examples of possible reasons for rejection are: intent with incorrect syntax, intent models required are not supported, there are no available resources to fulfil the intent after the modification, the requestor is not the RMIO responsible for that intent, among others. + +If the RMIH accepts the intent modification, all requirements affected by it would be replaced by the updated information. Immediately after the acceptance of a modification, the RMIH resumes the processing of the intent according to the latest information. + +### 6.6.1 Flow + +| Use Case Step | Description of the Step | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | RMIO wants to modify a set of requirements in an existing intent. | +| Actors and Roles | RMIO
RMIH
SMO
SME | +| Assumptions | The RMIO is an authorized SMO consumer for intents.
SMO has the SME services that support capabilities for RAN management Intents.
SMO exposes capabilities to handle RAN management intents via its available RMIHs
RMIH and RMIO know the unique ID of the Intent to be modified | +| Pre-conditions | The RMIO has previously provided the intent to an RMIH within the SMO.
The RMIO has verified that the RMIH supports intent modification.
The RMIH handling the intent to be modified is available and in operation in the SMO. | +| Begins when | The RMIO decides to modify one or more expectations within the intent. | +| Step 1 (M) | The RMIO requests the modification of the intent. It can request to add, remove or change requirements within an existing intent. | +| Step 2 (M) | The RMIH informs the RMIO that the intent modification request has been received. | +| Step 3 (M) | The RMIH starts the evaluation of the intent modification request and verifies if the new requirements can be accepted or should be rejected. | +| Step 4 (M) | The RMIH informs the RMIO about the acceptance/rejection of the modification request. | +| Step 5 (M) | The RMIH continues to send intent reports according to the reporting expectations, considering either the modified requirements (in case of modification was accepted) or the unchanged requirements (in case of modification was rejected). | +| Ends when | The RMIH has rejected or accepted the intent modification and has responded accordingly to the RMIO. | +| Exceptions | None | +| Post Conditions | N/A | + +Table 6.6.1-1: Modification of existing intents + +## 6.7 Intent Negotiation + +In Clause 4.1.1 we gave a brief overview of different possibilities which can take place during intent negotiation between the RMIO and the RMIH. Here we discuss them in detail. + +### 6.7.1 Intent feasibility check + +### 6.7.2 Intent exploration + +### 6.7.3 Intent fulfilment + +# 7 Recommended SMO Intent driven management requirements + +## 7.1 Overview + +This Clause lists the requirements which are recommended for intent-driven management in SMO + +## 7.2 Requirements for intent management in SMO + +| Number# | Description | +|-------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| SMO-INT_FUN052_01 | The SMO (via SME) shall expose the RAN Intent-driven management services to authorized SMO consumers. | +| SMO-INT_FUN052_02 | The SMO (via SME) shall provide discoverability of the RAN Intent-driven management capabilities offered by the SMO to authorized SMO consumers. | +| SMO-INT_FUN052_03 | The SMO (via SME) shall provide the registration service for the RAN management Intent handlers to register their intent handling capabilities. | +| SMO-INT_FUN052_04 | The RMIHs in the SMO shall register their RAN Intent management capabilities, including among others information about the Intent Driven Objects supported and reachability information of the RMIH. | +| SMO-INT_FUN053_01 | The SMO shall support the capabilities to process, fulfill, and assure Intent-driven management requests for RAN management. | +| SMO-INT_FUN053_02 | The SMO shall support the capabilities to provide reporting to SMO consumers on the RAN management intents they have requested to the SMO, according to the intent reporting requirements it received from the SMO consumers. | +| SMO-INT_FUN054_01 | The RMIH shall support the capability to remove the intent based on request from RMIO. | +| SMO-INT_FUN055_01 | The RMIH within the SMO should support the capability to assess the potential fulfilment of an intent and report it back to the RMIO. | +| SMO-INT_FUN055_02 | The RMIH within the SMO should support the capability to assess the potential outcome of an intent and report it back to the RMIO. | +| SMO-INT_FUN056_01 | The RMIH should be able to discover the capabilities of an RMIO. | +| SMO-INT_FUN056_02 | The RMIH within the SMO should support the capability to request that an RMIO provides its preferences on different possible outcomes for an intent. | +| SMO-INT_FUN056_03 | The RMIH within the SMO should support the capability to receive preferences from RMIO. | +| SMO-INT_FUN057_01 | The RMIO shall provide the requirements for intent reporting to the RMIH, including trigger events for reporting, scope of reporting, frequency of reporting, intent fulfilment status, intent fulfilment status change, and further content of reporting expected. | +| SMO-INT_FUN057_02 | The RMIH shall provide intent reports based on the reporting requirements received from an RMIO. | +| SMO-INT_FUN058_01 | The SMO shall support that the RMIO requests to modify the intent it has provided previously | +| SMO-INT_FUN058_02 | The RMIH within the SMO shall support the capability to evaluate intent modification requests from the RMIO. It shall be able to accept or reject modifications and inform the RMIO about the acceptance/rejection. | +| SMO-INT_FUN059_01 | The RMIO should support the capability to specify intent termination deadline for an intent to the RMIH | +| SMO-INT_FUN060_02 | The RMIH should support the capability to remove an intent from the system if the intent is not processed within the intent termination deadline | + +Table 7.2-1: Requirements for intent management in SMO + +# 8 SMO Intent driven management Analysis + +## 8.1 Overview + +## 8.2 SMO Architecture + +### 8.2.1 SMO Architecture Considerations + +#### 8.2.1.1 RMIH and RMIO roles support in SMO + +The O-RAN SMO architecture allows support for intent-based RAN management via support of one, or both, of the RMIH and/or RMIO roles in any SMOS Producer, for the exposure of the different SMOSs. This architectural approach enables: + +- Support for hierarchical intents: + - a SMOS Producer can take on the role of the RMIH, which after decomposing a RAN management intent can further make another/next level intent-based request that is processed by another SMOS Producer that has registered the RMIH capabilities to handle the decomposed intent(s), +- Support of intents in the SMOS Producer/Consumer in both SMO framework and in rApps: + - Any SMOS Producer/Consumer can take on the RMIH and/or RMIO roles, whether the SMOS Producer/Consumer provides SMO framework services, or it provides SMOSs realized via rApps. This implies that intent-based management support is also introduced over the R1 interface. + +#### 8.2.1.2 RMIH and RMIO capabilities registration and discovery in SMO + +A dynamic intent capabilities registration and discovery mechanism, which is very similar to the SME registration and discovery of SMOSs, needs to use an intent capabilities profile with standardized metadata, so it can be understood in an interoperable, multi-vendor way by SMOS Producers in the SMO, as well as by external SMO consumers taking the RMIO role. This can be a natural addition to SME, or it can be a separate (new) intents capability registry service. + +That will enable a flexible addition of new RMIHs to the SMO, of new intent-based models support, and of new RMIO capabilities, via the registration of the intent capabilities profiles that can be discovered by other RMIOs and RMIHs, whether internal to SMO or external. + +#### 8.2.1.3 RMIH and RMIO consumption of services and data + +Any SMOS Producer that acts in an RMIH or RMIO role can consume SMO services, as well as it can consume external services (outside SMO) and external data that they might need to either process intent-based requests, or respectively to make RAN management requests via intents. Some examples of SMO services consumption are: + +- DME data type registration, used by RMIHs to register intent related data, for discoverability by RMIOs, +- Consumption of any SMOSs by RMIHs, throughout the entire process of handling the intents and assuring their fulfilment, +- Consumption of any data types needed by RMIH, discovered via DME, +- Consumption of external services and/or data that is made accessible to the SMO, +- Consumption of Intent based exposure of the SMOSs. + +#### 8.2.1.4 RMIH and RMIO topology hiding + +The SMO's RMIHs can be hidden from the RMIOs (internal and/or external) via an intent abstraction layer, e.g., an intent proxy service. The Producer of this service would register RMIH and/or RMIO capabilities on behalf of RMIH and RMIO. + +Such intent proxy service would then have to also assume the capability to route any intent-based requests to the right RMIH instances for handling. The same approach can be taken with the RMIOs, for which a similar topology hiding can be applied for requests coming from the RMIHs (intent reports, judge requests, etc). + +#### 8.2.1.5 SMO Northbound exposure of RAN management via intents + +Current SMO architecture in [i.1] does not show an external exposure of RAN management services, via a northbound interface. While this is possible as described in the DEC\_SMO TR [i.4], the capabilities to expose SMO services northbound via intents is now added via this report. + +### 8.2.2 SMO Architecture Recommendations + +The intent-based management of the RAN is exposed by SMO via intent-based northbound interfaces that need to be further specified. The support of these intent-based requests for RAN management needs to also be added to the R1 interface, to enable rApps to provide intent based services in the RMIH and/or RMIO roles. Any SMOS Producer/Consumer can expose and consume intent-based interfaces for the SMOSs they produce or consume. + +Any of the SMOS Producers/Consumers can support the RMIH and/or RMIO roles. + +The ORAN intent modelling is modular and extensible. The intent modelling supported by an RMIH and RMIO is composed from a mandatory common model and a number of optional models' extension, to address the use cases identified in this report. This approach enables flexible model extensions that can be added for future use cases. The metadata of the intent capabilities' profiles for RMIH and RMIO roles needs to be standardized including their support of the optional model extensions, so that these capabilities can be registered and discovered in multi-vendor environments. + +The architecture details on the support for intents capabilities registration and discovery, as well as for the RMIH and RMIO topology hiding (intent proxy services) need to be specified in the SMO architecture. + +## 8.3 SMO Intent-driven Management Interface + +### 8.3.1 Intent Management interface approach + +The intent management interface serves for the communication between a RMIO (internal or external to the SMO) and a RMIH (in the SMO). This interface needs to support the the actions of feasibility check, lifecycle management by the RMIH, and reporting of a RAN management intent to the RMIO. Additionally, this interface may be used for advanced interactions (and associated negotiations) between the RMIO and the RMIH. + +### 8.3.2 Interface summary + +The communication via the Intent management interface primarily involves the exchange of two types of information objects between the RMIO and the RMIH: intents and intent reports. + +NOTE: the difference between use cases and capabilities as described in clause 5 will be addressed in stage 2. + +### 8.3.3 Interface recommendations + +Some recommendations for the next level of details of the SMO intent-driven management interface are: + +- The intent management interface to be based on OpenAPI/REST. +- The interface to allow an RMIO to provide an intent either for fulfilment or for exploration to a RMIH, as indicated by use case in clause 5.5. +- The interface to allow an RMIH to send a notification to the RMIO once an intent report to the RMIO based on the reporting requirements expressed by the RMIO is ready for collection, as indicated by use case in clause 5.7. +- The interface to support different types of interactions between a RMIO and a RMIH. These interactions may include (and not limited to): requests from RMIO to find achievable outcomes by RMIH on a requirement, suggestions from RMIH on different possible alternatives on a requirement, and so on, as indicated by the use cases in clause 5. +- The interface to enable an RMIH and an RMIO to expose its capabilities via a capability profile as part of the intent capability registration process. + +# --- Annex:Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.10.23 | 00.00.01 | Initial TR skeleton as approved at Madrid F2F meeting:
ATG:
ERI-2022.10.14-WG1-D-SMO-INT-TR-skeleton-proposal-v01.00.01.docx

UCTG: ERI-2022.10.14-WG1-D-SMO-INT-TR-skeleton-proposal-v01.00.01.docx | +| 2023.01.30 | 00.00.02 | Incorporated approved CR:
| +| 2023.05.16 | 00.00.03 | Incorporated approved CRs:
| +| 2023.07.31 | 00.00.04 | Incorporated approved CRs:
| +| 2023.09.08 | 00.00.05 | Incorporated approved CR:
| +| 2023.10.25 | 00.00.06 | Incorporated approved CRs:
| +| 2023.11.02 | 00.00.07 | Incorporated approved CRs:
| +| 2023.11.06 | 00.00.08 | Incorporated approved CRs:
Editorial:
  • removed the Annex examples inherited from the template since they were not used
  • removed leftover ENs under headings (originally indicating intended scoping of the sections – in 6, 7)
| +| 2023.11.14 | 00.00.09 | Minor editorial corrections: replaced comma with period, space missing between words, etc | +| 2023.11.22 | 00.00.10 | Incorporated editorial comments from WG approval: here towards v01.00 | +| 2024.03.18 | 01.00.01 | Incorporated approved CR:
| +| 2024.03.19 | 01.00.02 | Incorporated editorial comments from WG approval: here | +| 2024.03.27 | 01.00.03 | Incorporated last 2 comments from WG approval: here towards v02.00 | +| 2024.07.09 | 02.00.01 | Incorporated two approved CRs:
| +| 2024.07.15 | 02.00.02 | Incorporated one approved CR:
| +| 2024.07.15 | 02.00.03 | Corrected chapter number of 4.1.1 | + +| | | | +|------------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.07.25 | 02.00.04 | Incorporated last comments from WG approval: here towards v03.00
  • Updated document number, title page and change history to latest TR template
| +| 2024-11-15 | 03.00.01 | Incorporated approved CRs: | +| 2024-11-18 | 03.00.02 | Incorporated last comments from WG approval: here towards v04.00 | \ No newline at end of file diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/29a23bc491493b0b4b57bc9674761ab6_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/29a23bc491493b0b4b57bc9674761ab6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8b895770d260aba22d757020ebe673024b863590 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/29a23bc491493b0b4b57bc9674761ab6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:50836ce7a3d498189259cfb484052a4871f49e45dc286fcfe0ca18090dbaeb46 +size 94164 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/2a81f7aa3e36f84d971bfca1687419ff_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/2a81f7aa3e36f84d971bfca1687419ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7934865f647d6d3a85912704fe8aa421469603d0 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/2a81f7aa3e36f84d971bfca1687419ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd5231b2fe6e8194cd1ce60180fc768ee973421fcb606d02ad0c3f8ab23b95ab +size 48350 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/2b3c65b81c20f37a737486fb13043fc9_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/2b3c65b81c20f37a737486fb13043fc9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f5eb7c248b0c3b078a8642e004220d024d847582 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/2b3c65b81c20f37a737486fb13043fc9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:88e56e531d6c0b021a9b4de000120f0dd6c469dd851533ea3d5e8b279f6c1f16 +size 42178 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/2f921f74be7ec0cd4b940269afdfae04_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/2f921f74be7ec0cd4b940269afdfae04_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..947ff10599c7d4dbf62e646713578416a098aee7 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/2f921f74be7ec0cd4b940269afdfae04_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:854affa28ce0c211b10a575f2ce7ab5d6e895f9e221f0c80d73e182d74c83baa +size 67983 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/31b133db52549266cf81ce5fe3f68ab4_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/31b133db52549266cf81ce5fe3f68ab4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..80fcb3a6b185a71efc3ad79934d12205ee96fddb --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/31b133db52549266cf81ce5fe3f68ab4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aa23374a9e4eb37e2304698d42740b51be2f10e52d285db83384105ca526de8f +size 148256 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/328cb1933c827aa95fb7090375a16d04_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/328cb1933c827aa95fb7090375a16d04_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5efaf490aedd0b96b2714bd0d0a4ea4d15f10598 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/328cb1933c827aa95fb7090375a16d04_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7d2417bd88620f8741fb14b6f27a93fb55afb3dce0227ff4495de2ff4962e25c +size 77319 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/37729fb91b79a1d5c636538a3e1c256c_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/37729fb91b79a1d5c636538a3e1c256c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..21284858cfe56d9ec8db3ff6c1503c2c725b0bf6 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/37729fb91b79a1d5c636538a3e1c256c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8f039a9000346301e2c421f79ebff3da01f6b385f84178e4a717a4d6ac06bc88 +size 41723 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/39685c4b2f487ea8ee72adf4d032169a_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/39685c4b2f487ea8ee72adf4d032169a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b26fbb5251cf75fbb71404e5f004f0a4063f2e73 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/39685c4b2f487ea8ee72adf4d032169a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:693423bdf7da28db53da6165aa506c207e3a23ca79391c47b13d096b16db90e2 +size 105189 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/3cf93bcbc9bd52e47c40eb1b11a53aa1_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/3cf93bcbc9bd52e47c40eb1b11a53aa1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d2742fff1cce63e34d9b97b36f1e6f97c696ffe3 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/3cf93bcbc9bd52e47c40eb1b11a53aa1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3c279c3f41d79afa6da87905effda61dca4f90d697b849c00de24d04e53094ff +size 9532 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/42b5b51c58263d4f684e4de5cf2c1c5e_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/42b5b51c58263d4f684e4de5cf2c1c5e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e58054f4b4d6342bca08743961433435bcad405 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/42b5b51c58263d4f684e4de5cf2c1c5e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fdd855137b3219df9687fe08a9c5156cd3bbd8906f424c2f62a9b1d5f96705e6 +size 41860 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/4619d91bbae1a4a193459a8e9dc880e3_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/4619d91bbae1a4a193459a8e9dc880e3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aca7ec310b68fd2799a73201b5393fa04cbbf060 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/4619d91bbae1a4a193459a8e9dc880e3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b9a00f7b1f7560a76a5b035550d9a8990c363dd0eb1b6fdc89bd759c258f9bc1 +size 137850 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/4994db156275fd23db6efc171a058c31_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/4994db156275fd23db6efc171a058c31_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2ea11bd3e719dcae15352f75b2fc8030034b0707 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/4994db156275fd23db6efc171a058c31_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a30b26d183989ca6bc3467c10d40d64ce6aadd709636e403a14e24076eb87dd6 +size 217667 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/4f4518e51c251fad1672392b3f9dbc10_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/4f4518e51c251fad1672392b3f9dbc10_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3eb636118da5d20a899f4e580d091b83c419ec30 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/4f4518e51c251fad1672392b3f9dbc10_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3972116e6a591f2769cbe052c49f08edebd459cfc0348faaa275750e1756198a +size 237212 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/551e35d264492786d0d610557ccc1b55_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/551e35d264492786d0d610557ccc1b55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eca96f14eff173ab5ead5b4ef80ff5827e92c33d --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/551e35d264492786d0d610557ccc1b55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8bb0af2dd788e055159db7a05c0b9285e7d655c861421ac8dc37e4b94c3b343 +size 4454 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/6b17577390ea3a6abcb5725e8ba87d1d_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/6b17577390ea3a6abcb5725e8ba87d1d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a0852ded6b2fe878637c84e995e62ae560de9635 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/6b17577390ea3a6abcb5725e8ba87d1d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4b0e295f75eb20b73886259d1397cea3056b00219ae0952ef7846d626c91800a +size 59829 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/6f8a4e16275a66786a5ead8ea755fabb_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/6f8a4e16275a66786a5ead8ea755fabb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dbf7a8a2cadfb964c06a00c1fa31a925d03f3a02 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/6f8a4e16275a66786a5ead8ea755fabb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e7c850d82916475d428c9ada325be45054538cbaecc489088d4a999bd3b0e187 +size 69561 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/7e80f89dc3442da696f373a347994dbb_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/7e80f89dc3442da696f373a347994dbb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b73848c8798c29cd3f11b63f2cb107710aa72239 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/7e80f89dc3442da696f373a347994dbb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6040ac97f8bb07a7c74d386f41f3a657b308fd16dd4c989e90c4e37f7fdefb38 +size 251627 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/80ea99ccdfaddf8eff7067c4326526cd_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/80ea99ccdfaddf8eff7067c4326526cd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c2f0225be3a0d296828ba959c4493603751fc6f4 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/80ea99ccdfaddf8eff7067c4326526cd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:23f4c4489f9c460b99646479fbb5a171ad76cf8e8d335178b8cac66db694aa1c +size 44424 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/86b46dc467751bd111b3727806cd7f44_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/86b46dc467751bd111b3727806cd7f44_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c080240812ae6acc52a1048dc828f733a1793796 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/86b46dc467751bd111b3727806cd7f44_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:96ad0dcbc301849c8dac5a0731f2e3ebf91a83f8221e071e832f38796255eb30 +size 48869 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/8c08df601faa873f2eefa0a356daff5d_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/8c08df601faa873f2eefa0a356daff5d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c121ea1f814ea05a7dae12c771ee3b7198513fc4 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/8c08df601faa873f2eefa0a356daff5d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:169f294fb158922006108526ac3a60e20ae5443d8b70cdb7f498ec3d49606ce7 +size 59697 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/8fbab6b4bfe88dcbd4a63361edac7408_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/8fbab6b4bfe88dcbd4a63361edac7408_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f1ac6dffa38ac3fbf52fb69d2432d975e7ea2775 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/8fbab6b4bfe88dcbd4a63361edac7408_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6dc877d9b1bcda29fd3f180063153b2aeddee593e72c8b90bdf6a06d85d419f8 +size 38326 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/9090275a31042335e5d90b4abf001886_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/9090275a31042335e5d90b4abf001886_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ea17ba48a35190df6349c22d3e6cc999a2ba0f62 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/9090275a31042335e5d90b4abf001886_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fbbe30218dffce87437edeea77a1cb267a059213e8bbe157b30f3077e1ff4591 +size 123738 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/969e9809e0402a6147b1d3f5e7dff2e4_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/969e9809e0402a6147b1d3f5e7dff2e4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c51b8fde5e53ce2067647760089e31c2b9797e1e --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/969e9809e0402a6147b1d3f5e7dff2e4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7d392c0e05f9039fa42ba2bf2318823a9853fb73118dfa3c7479bb6218112577 +size 37100 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/9a7b18ee4c6a7b535e13586fa556b873_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/9a7b18ee4c6a7b535e13586fa556b873_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cebc44e0ca3bb0221ac1ec63de00f87cf89c9c53 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/9a7b18ee4c6a7b535e13586fa556b873_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64fcd924d8a3b6de8294e6868bcc81147e2d5d7926caa814ec26c7397d006e4f +size 95696 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/a11d6ea495980d5cd31e6330976825a2_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/a11d6ea495980d5cd31e6330976825a2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6d2723cceaac18ce874e1ea665fbec5c3cdadca3 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/a11d6ea495980d5cd31e6330976825a2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cce407a53f2f9f9a06b095cd7274886134fae9cb2703af73097a9abb4d3d12d5 +size 98980 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/a1697f3b1349fd1f8b0f0ef7ddfd41ef_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/a1697f3b1349fd1f8b0f0ef7ddfd41ef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..27598e70533a0ec7dd1c6026edc1760431867875 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/a1697f3b1349fd1f8b0f0ef7ddfd41ef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:168dc6e23b2aac9376a60aa7a8ba0b20335968a2cdf2401ea36b23b1e46f104e +size 43730 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/af390dd7b3278195fc2d70b21b567b65_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/af390dd7b3278195fc2d70b21b567b65_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..62bc6ea5eefe31565e431c5bc33f2acc335f711f --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/af390dd7b3278195fc2d70b21b567b65_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:143f4376283710543ab4f2d4c737885ee69ff1cca2606f5ac95f474e6226d3a0 +size 121640 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/b24e985393818f90861068f479c24911_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/b24e985393818f90861068f479c24911_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aeb50a4fb8b94dc42122a3047937f8331d2a82ec --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/b24e985393818f90861068f479c24911_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:519e5c8816e7ed6d0ca7be391bc117a34124c6b7cc4a1846aab0470a040bfc00 +size 4558 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/b6d267c207fc401bef94bdfe9035f5fd_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/b6d267c207fc401bef94bdfe9035f5fd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4e65e6583ec9f233318f39a38b76b86488370b35 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/b6d267c207fc401bef94bdfe9035f5fd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7ccd61e26018acf0d4c311bffd599811f3e88b454a1685ea46b2ae168d2f2c16 +size 252249 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7575c364a05dd515d7cf096c30ffc26f8ab2631 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b321cfff0a169d11fa6daa2e14ee4667e12bcfeff34e35ee9dd80b810a6385a6 +size 4491 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/be5b6e4083a92d22f57cd9adacf2649e_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/be5b6e4083a92d22f57cd9adacf2649e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0e4b658c3c0725fbe04a459b6f37012795b78b33 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/be5b6e4083a92d22f57cd9adacf2649e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:28a94290fd4bc59bb73a9e6a25afbcc890dac979599d1da099d4e7f174322ab7 +size 52311 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d44cc0f93247df950549918efda53e70_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d44cc0f93247df950549918efda53e70_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e38d91bf854fe70a5f3fa173acd9fdbcff04ce82 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d44cc0f93247df950549918efda53e70_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:467f922b9ef74b7f4122f6fba35765f415c0485d757508c20fb4a09dcc1aedc2 +size 108530 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d78d6db05a11fc37e743cf2b10000870_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d78d6db05a11fc37e743cf2b10000870_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2b3ca3f1eed72ef251fa57c8d0700d05173dbb11 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d78d6db05a11fc37e743cf2b10000870_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:44d1f3490b8bf6daea4a2a9e878f3ddf7c846b8ce0fd8cf111fad6fbf2da21d2 +size 53896 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2607b0eef27677fb38e9fdbba214fde5d86a7f72 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9e383e92647a2356488a833110e26ad296a5dd136dd01f365e78a67474a8258 +size 4548 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/db9a835541f84425c11ea43a7f337a78_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/db9a835541f84425c11ea43a7f337a78_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..422110b526b78f97acef4a25a36a22aa8856a200 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/db9a835541f84425c11ea43a7f337a78_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:27cbc47db3734f908c00a6b7557bd0f55109ff9e8dbc0ce2cda3dcc7b78cae76 +size 52259 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/ec8e910924591f6c85a77de7fd673aaf_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/ec8e910924591f6c85a77de7fd673aaf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..046d650e50b3fa693e279e3ea49e9b72a1c3e4db --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/ec8e910924591f6c85a77de7fd673aaf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ef25ea0dfb4c3ea99f4dc92de9c43c545f202b26b40f71c221056333a3260f8 +size 51028 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/f194427ba7fc38d53a3cf6999ff49d96_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/f194427ba7fc38d53a3cf6999ff49d96_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e1de505d67391bde22142817e8cdd906a4559afa --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/f194427ba7fc38d53a3cf6999ff49d96_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:095dec8608142611a54e3c4bf0995c7484a350fd99fd94f934e2b37634e7f72b +size 99783 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/f24058b554b0ae06b5af160beabbbb18_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/f24058b554b0ae06b5af160beabbbb18_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8689f7cc03bed9e6113b9c24a1f72b2e53c43f2e --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/f24058b554b0ae06b5af160beabbbb18_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0b62ec22252fee34f3e968863e2ef5a08bca642c87c5e0c4f51950acf5dda56c +size 85705 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/raw.md b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..b761cb9699cb37ad6187ec3046f3a7d657dd2c82 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00/raw.md @@ -0,0 +1,2126 @@ + + +# --- **O-RAN Work Group 1 (Use Cases and Overall Architecture)****Slicing Architecture** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|-------------------------------------------------------------------------------------------|----| +| Foreword..... | 4 | +| Modal verbs terminology ..... | 4 | +| 1 Scope..... | 5 | +| 2 References..... | 5 | +| 2.1 Normative references..... | 5 | +| 2.2 Informative references..... | 6 | +| 3 Definition of terms, symbols and abbreviations..... | 7 | +| 3.1 Terms..... | 7 | +| 3.2 Symbols..... | 8 | +| 3.3 Abbreviations..... | 8 | +| 4 Slicing overview..... | 9 | +| 5 High-level O-RAN slicing use cases..... | 10 | +| 5.1 O-RAN slicing use cases ..... | 10 | +| 5.2 O-RAN slice subnet management and provisioning use cases ..... | 10 | +| 5.2.1 O-RAN slice subnet instance creation..... | 10 | +| 5.2.2 O-RAN slice subnet instance activation..... | 12 | +| 5.2.3 O-RAN slice subnet instance modification ..... | 14 | +| 5.2.4 O-RAN slice subnet instance deactivation ..... | 16 | +| 5.2.5 O-RAN slice subnet instance termination ..... | 18 | +| 5.2.6 O-RAN slice subnet instance configuration ..... | 19 | +| 5.2.7 O-RAN slice subnet feasibility check ..... | 20 | +| 5.3 O-RAN slicing use cases ..... | 21 | +| 5.3.1 Use case 1: RAN slice SLA assurance..... | 21 | +| 5.3.2 Use case 2: Multi-vendor slices..... | 23 | +| 5.3.3 Use case 3: O-NSSI resource allocation optimization..... | 24 | +| 6 O-RAN slicing principles and requirements ..... | 27 | +| 6.1 General principles..... | 27 | +| 6.2 Slicing requirements ..... | 27 | +| 6.2.1 Functional requirements..... | 27 | +| 6.2.2 Non-functional requirements..... | 30 | +| 7 O-RAN reference slicing architecture..... | 31 | +| 7.1 O-RAN reference slicing architecture..... | 31 | +| 7.2 Non-RT RIC ..... | 31 | +| 7.3 Near-RT RIC ..... | 32 | +| 7.4 O-RAN Central Unit (O-CU-CP, O-CU-UP) ..... | 32 | +| 7.5 O-RAN Distributed Unit (O-DU) ..... | 32 | +| 7.6 A1 interface ..... | 33 | +| 7.7 E2 interface..... | 33 | +| 7.8 O1 interface ..... | 33 | +| 7.9 O2 interface ..... | 33 | +| 7.10 Transport network slicing ..... | 34 | +| 8 O-RAN slice subnet provisioning procedures..... | 36 | +| 8.1 O-RAN Slice Subnet Instance (O-NSSI) allocation procedure ..... | 36 | +| 8.2 O-RAN Slice Subnet Instance (O-NSSI) modification procedure..... | 39 | +| 8.3 O-RAN Slice Subnet Instance (O-NSSI) deallocation procedure..... | 41 | +| 8.4 O-RAN Slice Subnet Instance (O-NSSI) feasibility check and reservation procedure..... | 44 | +| 8.4.1 Introduction..... | 44 | +| 8.4.2 Procedure ..... | 44 | +| Annex A (informative): Implementation options ..... | 47 | +| A.1 Implementation options ..... | 47 | + +| | | | +|------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------|----| +| A.1.1 | 3GPP and ETSI NFV-MANO based O-RAN slicing architecture implementation option ..... | 47 | +| A.1.2 | ONAP based O-RAN slicing architecture implementation option ..... | 48 | +| Annex B (informative): Transport network slicing ..... | | 49 | +| B.1 | Transport network slicing use cases ..... | 49 | +| Annex C (informative): Slicing terminology..... | | 57 | +| C.1 | Slicing and 3GPP slice modeling terminology awareness ..... | 57 | +| C.1.1 | NSI and NSSI context in 3GPP SA2 and SA5 ..... | 57 | +| C.1.2 | Name containment limitation ..... | 57 | +| C.1.3 | Network slice subnet is a purposeful generic collection ..... | 58 | +| C.1.4 | Slicing instance example ..... | 59 | +| C.1.5 | NSSI slice profile and PLMNInfo ..... | 60 | +| C.1.6 | Managed functions have a list of PLMNInfo ..... | 61 | +| C.1.7 | Single Network Slice Selection Assistance Information (S-NSSAI) ..... | 61 | +| Annex D (informative): Multi-operator slice RAN management services exposure ..... | | 62 | +| D.1 | RAN management services exposure for multi-operator slice..... | 62 | +| D.1.1 | Management services exposure for multi-operator slice - Relevant standards..... | 63 | +| D.1.2 | Concepts of management services exposure for multi-operator slice ..... | 64 | +| D.1.3 | Management aspects of external exposure of MnS related to RAN slicing ..... | 65 | +| D.1.4 | Multi-operator slice: High-level use cases and potential requirements for exposure fo MnS related to O-RAN slicing ..... | 66 | +| Annex (informative): Change history/Change request (history) ..... | | 76 | + +# --- Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the high level O-RAN slicing related use cases, requirements and architecture. While some of the requirements are derived from use cases, some of the relevant SDO requirements are captured as they have impact on O-RAN functions. Along with requirements and reference slicing architecture, slicing related impact to O-RAN functions and interfaces are captured as well. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18, or the latest 3GPP release prior to Release 18 that includes that document. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are necessary for the application of the present document. + +- | | | +|------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [1] | 3GPP TS 22.261: Technical Specification Group Services and System Aspects; Service requirements for the 5G system; Stage 1 | +| [2] | 3GPP TS 23.501: Technical Specification Group Services and System Aspects; System Architecture for the 5G System; Stage 2 | +| [3] | 3GPP TS 28.526: Technical Specification Group Services and System Aspects; Telecommunication management; Life Cycle Management (LCM) for mobile networks that include virtualized network functions; Procedures | +| [4] | 3GPP TS 28.531: Management and orchestration; Provisioning, Release 16, March 2020. | +| [5] | 3GPP TS 28.532: Management and orchestration; Generic Management Services | +| [6] | Void | +| [7] | 3GPP TS 28.541: Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3 | +| [8] | 3GPP TS 28.552: Technical Specification Group Services and System Aspects; Management and orchestration; 5G performance measurements | +| [9] | 3GPP TS 32.300: Technical Specification Group Services and System Aspects; Telecommunication management; Configuration Management (CM); Name convention for managed objects | +| [10] | 3GPP TS 38.300: NR and NG-RAN Overall Description | +| [11] | ETSI GS NFV 003: Network Functions Virtualisation (NFV); Terminology for Main Concepts in NFV | +| [12] | Void | +| [13] | O-RAN.WG1.O1-Interface.0-v04.00: O-RAN Operations and Maintenance Interface Specification | +| [14] | Void | + +- [15] Void +- [16] Void +- [17] Void +- [18] O-RAN.WG6.ORCH-USE-CASES-v04.00: Orchestration Use Cases and Requirements for O-RAN Virtualized RAN +- [19] Void +- [20] Void +- [21] Void +- [22] Void +- [23] 3GPP TS 28.530: Management and orchestration; Concepts, use cases and requirements +- [24] O-RAN.WG11.Security-Protocols-Specification: “O-RAN Working Group 11 (Security Working Group) Security Protocols Specifications” + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18, or the latest 3GPP release prior to Release 18 that includes that document. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. +- [i.2] 3GPP TS 23.003: “Technical Specification Group Core Network and Terminals; Numbering, addressing and identification”. +- [i.3] 3GPP TR 28.801: “Study on management and orchestration of network slicing for next generation network”. +- [i.4] O-RAN\_Study\_ORAN\_Slicing\_Technical\_Report.v02.00: “Study on O-RAN Slicing”, Technical Report. +- [i.5] 3GPP TS 23.222: “Functional architecture and information flows to support Common API Framework for 3GPP Northbound APIs; Stage 2”, Release 17, June 2021. +- [i.6] 3GPP TS 29.222: “Common API Framework for 3GPP Northbound APIs”, Release 17, December 2021. +- [i.7] 3GPP TR 28.824: “Study on network slice management capability exposure”, Release 17, July 2022. +- [i.8] 3GPP TR 28.811: “Management and orchestration; Study on Network Slice Management Enhancement”, Release 17, December 2021. +- [i.9] 3GPP TR 23.700-99: “Study on Network Slice Capability Exposure for Application Layer Enablement”, Release 18, September 2022. + +- [i.10] Slicenet, . +- [i.11] NGMN Alliance: “5G P1 Requirements & Architecture “Description of Network Slicing Concept”, Version 1.0.8, September 2016. +- [i.12] O-RAN.WG1.OAM-Architecture-v04.00: “O-RAN WG1 Operations and Maintenance Architecture”. +- [i.13] O-RAN.WG2.A1.GA&P-v01.00: “O-RAN Working Group 2; (A1 interface: General Aspects and Principles)”. +- [i.14] O-RAN.WG3.E2GAP-v01.00: “O-RAN Working Group 3; Near-Real-time RAN Intelligent Controller Architecture & E2 General Aspects and Principles”. +- [i.15] O-RAN.WG6.CAD-V02.01: “Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN”. +- [i.16] O-RAN.WG9.XPSAAS-v01.00: “O-RAN Open Transport Working Group 9 Xhaul Packet Switched Architectures and Solutions”. +- [i.17] O-RAN.WG9.XTRP-REQ-v01.00: “O-RAN Open Xhaul Transport Working Group 9 Xhaul Transport Network Requirements”. +- [i.18] 3GPP TS 28.533: “Management and orchestration; Architecture framework”, Release 17, March 2022. +- [i.19] O-RAN.WG9.XTRP-MGT.0-v04.00: “O-RAN Open X-haul Transport Working Group Management interfaces for Transport Network Elements” + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions [given in [i.1] and the following] apply. A term defined in the present document takes precedence over the definition of the same term, if any, in [i.1]. + +**A1:** Interface between Non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**A1 policy:** Type of declarative policies expressed using formal statements that enable the Non-RT RIC function in the SMO to guide the Near-RT RIC function, and hence the RAN, towards better fulfilment of the RAN intent. + +**A1 enrichment information:** Information utilized by Near-RT RIC that is collected or derived at SMO/Non-RT RIC either from non-network data sources or from network functions themselves. + +**E2:** Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. + +**E2 Node:** A logical node terminating E2 interface. In the present document, O-RAN nodes terminating E2 interface are: + +- for NR access: O-CU-CP, O-CU-UP, O-DU or any combination. +- for E-UTRA access: O-eNB. + +**FCAPS:** Fault, Configuration, Accounting, Performance, Security. + +**Near-RT RIC:** O-RAN Near-Real-Time RAN Intelligent Controller: A logical function that enables near-real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. + +**Non-RT RIC:** O-RAN Non-Real-Time RAN Intelligent Controller: A logical function that enables non-real-time control and optimization of RAN elements and resources, AI/ML workflow including model training and updates, and policy-based guidance of applications/features in Near-RT RIC. + +**NMS:** A Network Management System. + +**Network Service:** Composition of network function(s) and/or network service(s), as specified in ETSI GS NFV 003 [11]. + +**Network Slice:** A network slice is a set of run-time network functions, and resources to run these network functions, forming a complete instantiated logical network to meet certain network characteristics required by the service instance(s). See reference NGMN 5G P1 Description of a Network Slice [i.11]. + +**Network Slice Instance (NSI):** A Managed Object Instance (MOI) of NetworkSlice IOC as specified in 3GPP TS 28.530 [23]. + +**NetworkSliceSubnet Instance (NSSI):** A Managed Object Instance (MOI) of NetworkSliceSubnet IOC as specified in 3GPP TS 28.530 [23]. + +**O-CU-CP:** O-RAN Central Unit – Control Plane: A logical node hosting the RRC and the control plane part of the PDCP protocol. + +**O-CU-UP:** O-RAN Central Unit – User Plane: A logical node hosting the user plane part of the PDCP protocol and the SDAP protocol. + +**O-DU:** O-RAN Distributed Unit: A logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. + +**O-RU:** O-RAN Radio Unit: A logical node hosting Low-PHY layer and RF processing based on a lower layer functional split. + +**O1:** Interface between the Service Management and Orchestration framework and O-RAN managed elements + +**O2:** Interface between the Service Management and Orchestration framework and the O-Cloud + +**RAN:** Generally referred as Radio Access Network. In terms of this document, any component below Near-RT RIC per O-RAN architecture, including O-CU-CP/O-CU-UP/O-DU/O-RU. + +**Resource isolation:** Regime of resource management when a resource used by one network slice instance cannot be shared with another network slice instance. See 3GPP TR 28.801 [i.3]. + +**Single Network Slice Selection Assistance Information (S-NSSAI):** An S-NSSAI is comprised of an SST (Slice/Service type) and an optional SD (Slice Differentiator) field (3GPP TS 28.541 [7], clause 4.3.37). + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations [given in [i.1] and the following] apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in [i.1]. + +| | | +|----|--------------------| +| DN | Distinguished Name | +|----|--------------------| + +| | | +|-------------|----------------------------------------------------------------------| +| eNB | eNodeB (applies to LTE) | +| gNB | gNodeB (applies to NR) | +| KPI | Key Performance Indicator | +| KQI | Key Quality Indicator | +| Near-RT RIC | O-RAN Near-Real-Time RIC | +| NFMF | Network Function Management Function | +| Non-RT RIC | O-RAN Non-Real-Time RIC | +| NS | Network Service | +| NSMF | Network Slice Management Function | +| NSSMF | Network Slice Subnet Management Function | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| PNF | Physical Network Function | +| PRB | Physical Resource Block | +| RIC | O-RAN RAN Intelligent Controller | +| RRM | Radio Resource Management | +| SD | Slice Differentiator | +| SDO | Standards Developing Organizations (For ex: 3GPP, ETSI, ONAP, O-RAN) | +| SMO | Service and Management Orchestration | +| SST | Slice/Service Type | +| VNF | Virtual Network Function | + +# 4 Slicing overview + +Network slicing is expected to play a critical role in 5G networks because of various use cases and services 5G will support. It allows a network operator to provide services tailored to customers' requirements. Network slice is defined as a logical network with a bundle of specified network services over a common network infrastructure. A single physical network is sliced into multiple virtual networks that may support different service types over a single RAN. 3GPP has standardized 6 different service types: eMBB, URLLC, MIoT, V2X, HMTc, and HDLCC as specified in 3GPP TS 23.501 [2]. + +3GPP defined 5G architecture and procedures containing network slicing and related concepts in Release 15. Furthermore, management and orchestration of 5G networks featuring slicing was defined in the 3GPP specifications. Other standard groups e.g. GSMA, ETSI NFV-MANO, ETSI ZSM and ONAP focus on the different aspects of network slicing. Further information regarding network slicing and other SDO's contributions was discussed in the Study on O-RAN Slicing Technical Report [i.4]. + +An example RAN slicing deployment of O-RAN network functions based on the select initial deployment option, option B as described in [i.15], is shown in figure 4-1, with some of the network functions shared between O-RAN slice subnets + +(such as O-CU-CP, O-DU, O-RU) and some network functions dedicated to a particular O-RAN slice subnet (such as O-CU-UP). + +![Figure 4-1: Example O-RAN slicing deployment. The diagram shows a three-stage architecture: Regional Cloud, Edge Cloud, and Cell Site. In the Regional Cloud, two network slices are shown: Subnet #1 (S-NSSAI=1) and Subnet #2 (S-NSSAI=2). Both slices pass through a Near-RT RIC. In the Edge Cloud, Subnet #1 passes through O-CU-CP and O-CU-UP, while Subnet #2 passes through O-CU-CP and O-CU-UP. Both slices then pass through O-DU. In the Cell Site, both slices pass through O-RU. The diagram uses color coding: green for Subnet #1 and blue for Subnet #2.](969e9809e0402a6147b1d3f5e7dff2e4_img.jpg) + +Figure 4-1: Example O-RAN slicing deployment. The diagram shows a three-stage architecture: Regional Cloud, Edge Cloud, and Cell Site. In the Regional Cloud, two network slices are shown: Subnet #1 (S-NSSAI=1) and Subnet #2 (S-NSSAI=2). Both slices pass through a Near-RT RIC. In the Edge Cloud, Subnet #1 passes through O-CU-CP and O-CU-UP, while Subnet #2 passes through O-CU-CP and O-CU-UP. Both slices then pass through O-DU. In the Cell Site, both slices pass through O-RU. The diagram uses color coding: green for Subnet #1 and blue for Subnet #2. + +Figure 4-1: Example O-RAN slicing deployment + +# 5 High-level O-RAN slicing use cases + +## 5.1 O-RAN slicing use cases + +This clause contains high-level O-RAN slicing use cases that O-RAN is expected to support. Slicing requirements are derived from the specified use cases. + +## 5.2 O-RAN slice subnet management and provisioning use cases + +Network slicing is conceived to be an end-to-end feature that includes the core network, transport network, and the RAN. Although 3GPP has started defining network slicing support with Release 15, slicing in O-RAN needs to be further addressed in line with 3GPP to achieve deployable network slicing in an open RAN environment. + +Management aspects of network slicing such as Network Slice Instances (NSI) and Network Slice Subnet Instances (NSSI) are specified in 3GPP TS 28.531 [4]. While NSI refers to an end-to-end network slice, NSSI refers to a part of an end-to-end network slice as a RAN slice subnet. The provisioning of network slicing includes the four phases which are preparation, commissioning, operation, and decommissioning. The NSI/NSSI provisioning operations shall include: + +- Create an NSI/NSSI; +- Activate an NSI/NSSI; +- De-active an NSI/NSSI; +- Modify an NSI/NSSI; +- Terminate an NSI/NSSI. + +Please refer to 3GPP TS 28.531 [4], clause 4.1 for further details of NSI and NSSI lifecycle management and provisioning. + +The following clauses define the use cases and procedures necessary for O-RAN slice subnet management that is in-line with 3GPP slice management framework. For this purpose, use cases such as slice subnet creation, activation, modification, deactivation, termination, configuration, and feasibility check are utilized by O-RAN architecture. + +### 5.2.1 O-RAN slice subnet instance creation + +The context of the O-RAN slice subnet instance creation use case is captured in table 5.2.1-1. + +**Table 5.2.1-1: O-RAN slice subnet instance creation use case** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------| +| Goal | Creation of a new O-RAN network slice subnet instance (O-NSSI) or use an existing O-NSSI to satisfy the O-RAN slice subnet related requirements (3GPP TS 28.531 [4], clause 5.1.2). | | +| Actors and Roles |

NSSMS_C, such as NSMF, who acts as the network slice subnet management service consumer.

NSSMS_P, such as NSSMF, who acts as the network slice subnet management service provider.

NFMS_P, such as SMO OAM functions or NFMF, who acts as the network function management service provider.

O-Cloud M&O, who acts as the O-Cloud management and orchestration provider within SMO.

Non-RT RIC

O-RAN Network Functions: NFs such as Near-RT RIC, O-CU-CP, O-CU-UP, O-DU and O-RU.

| | +| Assumptions | NSSMS_P has the knowledge of O-Cloud M&O to manage the lifecycle of VNFs and interconnection between the VNFs and PNFs. | | +| Pre-conditions | VNF packages for virtualized O-RAN network functions to be included in the O-RAN slice subnet instance have been already on-boarded. | | +| Begins when | NSSMS_P receives request for a network slice subnet instance. The request contains network slice subnet related requirements. | | +| Step 1 (M) | NSSMS_P checks the feasibility of the request, based on the received network slice subnet related requirements. | O-RAN slice subnet feasibility check | +| Step 2 (M) | NSSMS_P decides to create a new O-NSSI or use an existing O-NSSI. | | +| Step 3 (M) |

If an existing O-NSSI is decided to be used, NSSMS_P should trigger modification of the existing O-NSSI to satisfy the network slice subnet related requirements.

Go to “Step 11”.

Otherwise, NSSMS_P triggers creation of a new O-NSSI, continue with Step 4

| O-RAN slice subnet instance modification use case | +| Step 4 (M) | NSSMS_P derives the requirements for the constituent O-NSSI(s). | | +| Step 5 (O) |

If the required O-NSSI contains constituent O-NSSI(s) managed by other NSSMS_P(s), NSSMS_P may trigger creation of respective constituent O-NSSI(s) through other NSSMS_P(s) which manages the constituent O-NSSI(s).

In that case, NSSMS_P receives the constituent O-NSSI information from the other NSSMS_P(s) and associates the constituent O-NSSI(s) with the required O-NSSI.

| (O-RAN) slice subnet instance creation use case (to create constituent (O-)NSSI(s) managed by other NSSMS_P(s)) | +| Step 6 (M) | NSSMS_P determines the service-related requirements and triggers a service request to O-Cloud M&O for instantiation of virtual O-RAN network functions and virtual links within the determined O-Cloud(s). | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| | Based on the service request, O-Cloud M&O performs corresponding NF instantiation procedures and virtual link establishment. | | +| Step 7 (M) | NSSMS_P associates the service response received from O-Cloud M&O with the corresponding O-NSSI. | | +| Step 8 (M) | NSSMS_P uses (O-RAN) NF provisioning service exposed by NFMS_P to configure (O-)NSSI constituents. | | +| Step 9 (M) | NSSMS_P configures the O-NSSI MOI with each constituent (O-)NSSI MOI identifier. | | +| Step 10 (M) | NSSMS_P triggers O-RAN TN manager coordination procedure to establish necessary links such as for A1, E2, and midhaul and fronthaul connectivity. | | +| Step 11 (M) | NSSMS_P notifies Non-RT RIC with network slice subnet requirements and respective O-NSSI information. | | +| Step 12 (M) | NSSMS_P notifies NSSMS_C with the resulting status of this process and relevant O-NSSI information. | | +| Ends when | O-RAN O-NSSI and relevant O-RAN NFs are created, and Non-RT RIC is configured with slice requirements and O-NSSI information. | | +| Exceptions | One of the steps identified above fails. | | +| Post Conditions | O-NSSI is ready to satisfy the network slice subnet related requirements. | | +| Traceability | REQ-SL-FUN14, REQ-SL-FUN20 - REQ-SL-FUN27 | | + +### 5.2.2 O-RAN slice subnet instance activation + +The context of the O-RAN slice subnet instance activation use case is captured in table 5.2.2-1. + +**Table 5.2.2-1: O-RAN slice subnet instance activation use case** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Activation of an O-RAN network slice subnet instance (O-NSSI) (3GPP TS 28.531 [4], clause 5.1.10). | | +| Actors and Roles |

NSSMS_C, such as NSMF, who acts as the network slice subnet management service consumer.

NSSMS_P, such as NSSMF, who acts as the network slice subnet management service provider.

NFMS_P, such as SMO OAM functions or NFMF, who acts as the network function management service provider.

O-RAN network functions: NFs such as Near-RT RIC, O-CU-CP, O-CU-UP, O-DU and O-RU.

| | +| Assumptions | NSSMS_P is providing services to authorized consumers. | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Pre-conditions |

An O-NSSI has already been created and it is inactive.

As an example, the O-NSSI may contain inactive O-RAN NFs:- Near-RT RIC is installed and active

  • - O-CU-CP installed (i.e. operationalState = enabled), but not yet activated (i.e. administrativeState = locked).
  • - O-CU-UP installed (i.e. operationalState = enabled), but not yet activated (i.e. administrativeState = locked).
  • - O-DU installed (i.e. operationalState = enabled), but not yet activated (i.e. administrativeState = locked) (3GPP TS 28.541 [7], figure B.2.1).
  • - O-RU physically installed (i.e. operationalState = enabled), but not yet activated (i.e. administrativeState = locked).

See NOTE 1.

| | +| Begins when | NSSMS_P decides to activate the O-NSSI based on the received network slice subnet related request from its authorized consumer NSSMS_C. | | +| Step 1 (M) | NSSMS_P receives a request from NSSMS_C to activate the O-NSSI (via O-NSSI provisioning service with operation modifyMOIAttributes (3GPP TS 28.531 [4], table 6.2-1) to change administrativeState of the O-NSSI to unlocked .) | | +| Step 2 (M) |

NSSMS_P identifies the inactive constituents within the O-NSSI and decides to activate those constituents which can be NFs or O-NSSI.

As an example, NSSMS_P activates the following inactive O-RAN NF constituents:

  • - the O-CU-CP NF constituent, and invokes NF provisioning service with operation modifyMOIAttributes (3GPP TS 28.531 [4], table 6.3-1) to request NFMS_P to activate the O-CU-CP by changing the administrativeState of the O-CU-CP to unlocked.

See NOTE 2.

  • - the O-CU-UP NF constituent, and invokes NF provisioning service with operation modifyMOIAttributes (3GPP TS 28.531 [4], table 6.3-1) to request NFMS_P to activate the O-CU-UP by changing the administrativeState of the O-CU-UP to unlocked.

See NOTE 3, NOTE 4.

  • - the O-DU NF constituent, and invokes NF provisioning service with operation modifyMOIAttributes (3GPP TS 28.531 [4], table 6.3-1) to request NFMS_P to activate the O-DU by changing the administrativeState of the O-DU to unlocked.

See NOTE 5, NOTE 6.

| | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| |
  • - the O-RU NF constituent, and invokes NF provisioning service with operation modifyMOIAttributes (3GPP TS 28.531 [4], table 6.3-1) to request NFMS_P to activate the O-RU by changing the administrativeState of the O-RU to unlocked.

See NOTE 7.

| | +| Step 3 (M) | NSSMS_P receives notifications indicating that all inactive O-NSSI constituents are activated. (NSSMS_P is notified by respective NFMS_P(s) through NF provisioning data report service with notification notifyMOIAttributeValueChanges (3GPP TS 28.531 [4], table 6.3-1) that the O-CU-CP, O-CU-UP, O-DU and O-RU have been activated.) | | +| Step 4 (M) | NSSMS_P changes administrativeState of the O-NSSI to unlocked , and invokes O-NSSI provisioning data report service with notification notifyMOIAttributeValueChanges (3GPP TS 28.531 [4], table 6.2-1) to notify NSSMS_C that the O-NSSI has been activated. | | +| Ends when | O-RAN O-NSSI is activated. | | +| Exceptions | One of the steps identified above fails. | | +| Post Conditions | O-NSSI is in operation. | | +| Traceability | REQ-SL-FUN25, REQ-SL-FUN28 | | +|

NOTE 1: The O-CU-CP, O-CU-UP, O-DU and O-RU are not shared by other O-NSSI, since they are not yet activated. Near-RT RIC has already been activated for other services.

NOTE 2: O-CU-CP triggers establishment of the E2 interface connection with Near-RT RIC.

NOTE 3: O-CU-UP triggers establishment of the E2 interface connection with Near-RT RIC.

NOTE 4: E1 interface connection will be established between O-CU-CP and O-CU-UP.

NOTE 5: O-DU triggers establishment of the F1 interface connection with O-CU-CP and O-CU-UP, (3GPP TS 28.541 [7], Annex A.1).

NOTE 6: O-DU triggers establishment of the E2 interface connection with Near-RT RIC.

NOTE 7: O-RU triggers establishment of the M plane interface connection with O-DU (O-RAN.WG1.O1-Interface.0-v04.00 [13]).

| | | + +### 5.2.3 O-RAN slice subnet instance modification + +The context of the O-RAN slice subnet instance modification use case is captured in table 5.2.3-1. + +**Table 5.2.3-1: O-RAN slice subnet instance modification use case** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|----------------|---------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Modification of an existing O-NSSI to satisfy O-RAN slice subnet related requirements (3GPP TS 28.531 [4], clause 5.1.9). | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------| +| Actors and Roles |

NSSMS_C, such as NSMF, who acts as the network slice subnet management service consumer.

NSSMS_P, such as NSSMF, who acts as the network slice subnet management service provider.

NFMS_P, such as SMO OAM functions or NFMF, who acts as the network function management service provider.

O-Cloud M&O, who acts as the O-Cloud management and orchestration provider within SMO.

Non-RT RIC

O-RAN network functions: NFs such as Near-RT RIC, O-CU-CP, O-CU-UP, O-DU and O-RU.

| | +| Assumptions | NSSMS_P has the knowledge of O-Cloud M&O to manage the lifecycle of VNFs and interconnection between the VNFs and PNFs. | | +| Pre-conditions | VNF packages for virtualized O-RAN network functions to be included in the O-RAN slice subnet instance have been already on-boarded. | | +| Begins when | NSSMS_P receives request for a modification of an existing O-NSSI. The request contains new network slice subnet related requirements. | | +| Step 1 (M) | NSSMS_P checks the feasibility of the request, based on the received network slice subnet related modification requirements. If the modification requirements can be satisfied, go to step 2, else go to step 8. | O-RAN slice subnet feasibility check | +| Step 2 (M) | NSSMS_P decomposes the O-NSSI modification request into modification requests for each (O-)NSSI constituent. | | +| Step 3 (O) |

If the required O-NSSI contains constituent (O-)NSSI(s) managed by other NSSMS_P(s), NSSMS_P may trigger modification of respective constituent (O-)NSSI(s) through other NSSMS_P(s) which manages the constituent (O-)NSSI(s).

In that case, NSSMS_P receives the constituent (O-)NSSI information from the other NSSMS_P(s) and associates the constituent (O-)NSSI(s) with the required O-NSSI.

| (O-RAN) slice subnet instance modification use case (to modify constituent (O-)NSSI(s) managed by other NSSMS_P(s)) | +| Step 4 (O) | If the O-NSSI contains virtualized part(s), NSSMS_P triggers a service modification request to O-Cloud M&O for scaling, updating, instantiation etc. of virtual O-RAN network functions and virtual links within the determined O-Cloud(s). | | +| Step 5 (O) | If the O-NSSI consists of NF instances, NSSMS_P uses NF provisioning service exposed by NFMS_P to (re-)configure (O-)NSSI constituents. | | +| Step 6 (O) | If the O-NSSI contains TN part, NSSMS_P triggers O-RAN TN manager coordination procedure to establish/modify necessary links such as for A1, E2, midhaul and fronthaul connectivity. | | +| Step 7 (M) | NSSMS_P notifies Non-RT RIC with the updated network slice subnet requirements and respective O-NSSI information. | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Step 8 (M) | NSSMS_P notifies NSSMS_C with the resulting status of this process and relevant O-NSSI information. | | +| Ends when | O-RAN O-NSSI and relevant O-RAN NFs are modified, and Non-RT RIC is configured with modified slice requirements and O-NSSI information. | | +| Exceptions | One of the steps identified above fails. | | +| Post Conditions | O-NSSI is ready to satisfy the updated network slice subnet related requirements. | | +| Traceability | REQ-SL-FUN24 - REQ-SL-FUN27, REQ-SL-FUN29, REQ-SL-FUN30 | | + +### 5.2.4 O-RAN slice subnet instance deactivation + +The context of the O-RAN slice subnet instance deactivation use case is captured in table 5.2.4-1. + +**Table 5.2.4-1: O-RAN slice subnet instance deactivation use case** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Deactivation of an O-RAN network slice subnet instance (O-NSSI) (3GPP TS 28.531 [4], clause 5.1.11). | | +| Actors and Roles | NSSMS_C, such as NSMF, who acts as the network slice subnet management service consumer.

NSSMS_P, such as NSSMF, who acts as the network slice subnet management service provider.

NFMS_P, such as SMO OAM functions or NFMF, who acts as the network function management service provider.

O-RAN network functions: NFs such as Near-RT RIC, O-CU-CP, O-CU-UP, O-DU and O-RU. | | +| Assumptions | NSSMS_P is providing services to authorized consumers. | | +| Pre-conditions | An O-NSSI has already and it is in active state.

As an example, the existing O-NSSI includes active O-CU-CP, O-CU-UP, O-DU and O-RU O-RAN NFs, where the administrativeState is unlocked (3GPP TS 28.541 [7], figure B.2.1). See NOTE 1. | | +| Begins when | NSSMS_C decides to deactivate the O-NSSI based on the received network slice subnet related request from its authorized consumer NSSMS_C. | | +| Step 1 (M) | NSSMS_P receives a request from NSSMS_C to deactivate the O-NSSI (via O-NSSI provisioning service with operation modifyMOIAttributes (3GPP TS 28.531 [4], table 6.2-1) to request NSSMS_P to deactivate the O-NSSI that is to change administrativeState of the O-NSSI to locked ). | | +| Step 2 (M) | NSSMS_P identifies active constituents (e.g. O-NSSI, NF) of the O-NSSI and decides to deactivate those constituents. | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| |

As an example, NSSMS_P finds that the O-NSSI contains active non-shared O-RAN NFs:

  • - the O-CU-CP NF constituent, and invokes NF provisioning service with operation modifyMOIAttributes (3GPP TS 28.531 [4], table 6.3-1) to request NFMS_P to deactivate the O-CU-CP by changing the administrativeState of the O-CU-CP to locked.

See NOTE 2, NOTE 3.

  • - the O-CU-UP NF constituent, and invokes NF provisioning service with operation modifyMOIAttributes (3GPP TS 28.531 [4], table 6.3-1) to request NFMS_P to deactivate the O-CU-UP by changing the administrativeState of the O-CU-UP to locked.

See NOTE 4.

  • - the O-DU NF constituent, and invokes NF provisioning service with operation modifyMOIAttributes (3GPP TS 28.531 [4], table 6.3-1) to request NFMS_P to deactivate the O-DU by changing the administrativeState of the O-DU to locked.

See NOTE 5, NOTE 6.

  • - the O-RU constituent, and invokes NF provisioning service with operation modifyMOIAttributes (3GPP TS 28.531 [4], table 6.3-1) to request NFMS_P to deactivate the O-RU by changing the administrativeState of the O-RU to locked.

See NOTE 7.

| | +| Step 3 (M) |

NSSMS_P receives notifications indicating that all active non-shared O-NSSI constituents are deactivated.

(NSSMS_P is notified by respective NFMS_P(s) which invoke NF provisioning data report service with notification notifyMOIAttributeValueChanges (3GPP TS 28.531 [4], table 6.3-1) to notify that the O-CU-CP, O-CU-UP, O-DU and O-RU have been deactivated.)

| | +| Step 4 (M) | NSSMS_P changes administrativeState of the O-NSSI to locked , and invokes O-NSSI provisioning data report service with notification notifyMOIAttributeValueChanges (3GPP TS 28.531 [4], table 6.2-1) to notify NSSMS_C that the O-NSSI has been deactivated. | | +| Ends when | O-RAN O-NSSI is deactivated. | | +| Exceptions | One of the steps identified above fails. | | +| Post Conditions | O-NSSI is inactive. | | +| Traceability | REQ-SL-FUN25, REQ-SL-FUN31 | | +| NOTE 1: The O-CU-CP, O-CU-UP, O-DU and O-RU are not shared by other O-NSSI. | | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------|-------------------------| +|

NOTE 2: O-CU-CP triggers termination of the E2 interface connection with Near-RT RIC.

NOTE 3: E1 interface connection will be released between O-CU-CP and O-CU-UP.

NOTE 4: O-CU-UP triggers termination of the E2 interface connection with Near-RT RIC.

NOTE 5: O-DU triggers termination of the F1 interface connection with O-CU-CP and O-CU-UP (3GPP TS 28.541 [7], Annex A.1).

NOTE 6: O-DU triggers termination of the E2 interface connection with Near-RT RIC.

NOTE 7: O-RU triggers termination of the M plane interface connection with O-DU (O-RAN.WG1.O1-Interface.0-v04.00 [13]).

| | | + +### 5.2.5 O-RAN slice subnet instance termination + +The context of the O-RAN slice subnet instance termination use case is captured in table 5.2.5-1. + +**Table 5.2.5-1: O-RAN slice subnet instance termination use case** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------| +| Goal | Termination or disassociation of an existing O-RAN network slice subnet instance (O-NSSI) (3GPP TS 28.531 [4], clause 5.1.4). | | +| Actors and Roles |

NSSMS_C, such as NSMF, who acts as the network slice subnet management service consumer.

NSSMS_P, such as NSSMF, who acts as the network slice subnet management service provider.

O-Cloud M&O, who acts as the O-Cloud management and orchestration provider within SMO.

Non-RT RIC

O-RAN network functions: NFs such as Near-RT RIC, O-CU-CP, O-CU-UP, O-DU and O-RU.

| | +| Assumptions | NSSMS_P has the knowledge of O-Cloud M&O to manage the lifecycle of VNFs and interconnection between the VNFs and PNFs. | | +| Pre-conditions | O-NSSI exists, and it is in inactive state. | | +| Begins when | NSSMS_P receives a request for an O-RAN network slice subnet instance indicating that the O-NSSI is no longer needed. The request contains network slice subnet identifier. | | +| Step 1 (M) |

NSSMS_P checks whether the O-NSSI is a shared network slice subnet instance.

If the O-NSSI is shared, O-NSSI shall be disassociated via O-NSSI slice subnet instance modification use case. Go to step 5.

| O-RAN slice subnet instance modification use case | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------| +| | If the O-NSSI is not shared, O-NSSI shall be terminated. Go to step 2. | | +| Step 2 (M) | If the O-NSSI consists of constituent O-NSSIs that are not managed directly by the NSSMS_P, it sends a request to other NSSMS_P(s) indicating that the constituent O-NSSIs are no longer needed for the O-NSSI. | O-RAN slice subnet instance termination use case | +| Step 3 (O) | NSSMS_P may trigger a service termination request to O-Cloud M&O for removal of non-shared virtual O-RAN network functions. | | +| Step 4 (O) | If the O-NSSI includes constituent transport links, NSSMS_P may trigger O-RAN TN manager coordination procedure. | | +| Step 5 (M) | NSSMS_P notifies Non-RT RIC that the O-NSSI has been terminated. | | +| Step 6 (M) | NSSMS_P notifies NSSMS_C with the resulting status of this process and relevant O-NSSI information. | | +| Ends when | All the steps identified above are successfully completed. | | +| Exceptions | One of the steps identified above fails. | | +| Post Conditions | O-NSSI has been terminated or disassociated and Non-RT RIC is notified. | | +| Traceability | REQ-SL-FUN21, REQ-SL-FUN23, REQ-SL-FUN27, REQ-SL-FUN32 - REQ-SL-FUN34 | | + +### 5.2.6 O-RAN slice subnet instance configuration + +The context of the O-RAN slice subnet instance configuration use case is captured in table 5.2.6-1. + +**Table 5.2.6-1: O-RAN slice subnet instance configuration use case** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Configuration of an O-NSSI (3GPP TS 28.531 [4], clause 5.1.13). | | +| Actors and Roles |

NSSMS_C, such as NSMF, who acts as the network slice subnet management service consumer.

NSSMS_P, such as NSSMF, who acts as the network slice subnet management service provider.

NFMS_P, such as SMO OAM functions or NFMF, who acts as the network function management service provider.

O-RAN network functions: NFs such as Near-RT RIC, O-CU-CP, O-CU-UP, O-DU and O-RU.

| | +| Assumptions |

NSSMS_P is providing services to authorized consumers.

NSSMS_P has the knowledge of the respective NSSMS_P(s) and NFMS_P(s) which manages the constituent O-NSSI(s) and NF(s).

| | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------| +| Pre-conditions | The O-NSSI exists. | | +| Begins when | NSSMS_C triggers the (re-)configuration of an O-NSSI and its constituents. | | +| Step 1 (M) | NSSMS_P receives a request from NSSMS_C with slice subnet (re-)configuration information for (re-)configuration of an O-NSSI. | | +| Step 2 (M) | NSSMS_P decomposes the received slice subnet configuration information and prepares CM requests for each constituent if necessary and applicable. | | +| Step 3 (O) | NSSMS_P configures the constituent O-NSSI(s) if it is managed directly by the NSSMS_P. | | +| Step 4 (O) | If the O-NSSI contains constituent O-NSSI(s) managed by other NSSMS_P(s), NSSMS_P triggers configuration of respective constituent O-NSSI(s) through NSSMS_P(s) which manages the constituent O-NSSI(s). | (O-RAN) slice subnet configuration use case | +| Step 5 (O) | If the required O-NSSI contains constituent O-RAN NF(s) managed by NFMS_P(s), NSSMS_P may trigger configuration requests with corresponding slice subnet configuration information through NFMS_P(s) which manages the constituent O-RAN NF(s). | | +| Step 6 (M) | NSSMS_P sends the configuration result to the NSSMS_C which may be based on results received from other CM service providers. | | +| Ends when | All the steps identified above are successfully completed. | | +| Exceptions | One of the steps identified above fails. | | +| Post Conditions | The required (re-)configuration is accomplished at the corresponding constituent(s). | | +| Traceability | REQ-SL-FUN24, REQ-SL-FUN25 | | + +### 5.2.7 O-RAN slice subnet feasibility check + +The context of the O-RAN slice subnet feasibility check is captured in table 5.2.7-1. + +**Table 5.2.7-1: O-RAN slice subnet feasibility check** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | To check the feasibility of provisioning an O-RAN network slice subnet instance (O-NSSI) to determine whether the O-NSSI requirements can be satisfied (e.g., in terms of resources) (3GPP TS 28.531 [4], clause 5.1.21). | | +| Actors and Roles |

NSSMS_C, such as NSMF, who acts as the network slice subnet management service consumer.

NSSMS_P, such as NSSMF, who acts as the network slice subnet management service provider.

NFMS_P, such as SMO OAM functions or NFMF, who acts as the network function management service provider.

| | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------| +| |

O-Cloud M&O, who acts as the O-Cloud management and orchestration provider within SMO.

Non-RT RIC

O-RAN network functions: NFs such as Near-RT RIC, O-CU-CP, O-CU-UP, O-DU and O-RU.

| | +| Assumptions | NSSMS_C has decided to check the feasibility of provisioning an O-NSSI based on, for example, internal decision or an external service request. | | +| Pre-conditions | Network slice subnet requirements have been derived or received by network slice subnet management service consumer NSSMS_C. | | +| Begins when | NSSMS_P receives the request to evaluate the feasibility of an O-NSSI according to the network slice subnet requirements. | O-RAN slice subnet instance creation, O-RAN slice subnet instance modification | +| Step 1 (M) | NSSMS_P identifies the network slice subnet constituents according to the requirements, e.g., network services to be requested from O-Cloud M&O. | | +| Step 2 (O) | For the purpose of checking the feasibility of provisioning an O-NSSI, NSSMS_P may obtain information from the SMO and Non-RT RIC (e.g., load level information, resource usage information from management data analytics services). | | +| Step 3 (M) | NSSMS_P sends enquiries with reservation requests to O-Cloud M&O to determine availability of network constituents, e.g., network services, network functions. | | +| Step 4 (O) | For the purpose of checking the feasibility of transport network links, NSSMS_P may obtain information from TN manager. | | +| Ends when | NSSMS_P provides feasibility check results to NSSMS_C. If provisioning of O-NSSI is feasible, the information about reserved resources may also be provided. | | +| Exceptions | One of the mandatory steps fails. | | +| Post Conditions | N/A | | +| Traceability | REQ-SL-FUN35 - REQ-SL-FUN37 | | + +## 5.3 O-RAN slicing use cases + +### 5.3.1 Use case 1: RAN slice SLA assurance + +In the 5G era, network slicing is a prominent feature which provides end-to-end connectivity and data processing tailored to specific business requirements. These requirements include customizable network capabilities such as the support of very high data rates, traffic densities, service availability and very low latency. According to 5G standardization efforts, the 5G system can support the needs of the business through the specification of several service needs such as data rate, traffic capacity, user density, latency, reliability, and availability. These capabilities are always provided based on a Service + +Level Agreement (SLA) between the mobile operator and the business customer, which brought up interest for mechanisms to ensure slice SLAs and prevent its possible violations. O-RAN's open interfaces and AI/ML based architecture will enable such challenging mechanisms to be implemented and help pave the way for operators to realize the opportunities of network slicing in an efficient manner. + +RAN slice SLA assurance scenario involves Non-RT RIC, Near-RT RIC, E2 Nodes and SMO interaction. The scenario starts with the retrieval of RAN specific slice SLA/requirements (possibly within SMO or from NSSMF depending on operator deployment options). Based on slice specific performance measurements from E2 Nodes, Non-RT RIC and Near-RT RIC can fine-tune RAN behavior aligned with O-RAN architectural roles to assure RAN slice SLAs. Non-RT RIC monitors long-term trends and patterns for O-RAN slice subnets' performance and employs AI/ML methods to perform corrective actions through SMO (e.g. reconfiguration via O1) or via creation of A1 policies. Non-RT RIC can also construct/train relevant AI/ML models that will be deployed at Near-RT RIC. A1 policies possibly include scope identifiers (e.g. S-NSSAI) and statements such as KPI targets. On the other hand, Near-RT RIC enables optimized RAN actions through execution of deployed AI/ML models in near-real-time by considering both O1 configuration (e.g. static RRM policies) and received A1 policies, as well as received slice specific E2 measurements. + +An overview of RAN slice SLA assurance use case is given in figure 5.3.1-1. + +![Figure 5.3.1-1: RAN slice SLA assurance use case overview. The diagram shows the interaction between the Service, Management & Orchestration Framework (SMO), Non-Real Time RIC, Near-RT RIC, and E2 Nodes. The SMO (orange box) contains the Non-Real Time RIC (green box) and the Near-RT RIC (blue box). The Non-Real Time RIC is connected to the Near-RT RIC via the A1 interface. The Near-RT RIC is connected to the E2 Nodes (grey box) via the E2 interface. The Non-Real Time RIC is also connected to the E2 Nodes via the O1 interface. The diagram includes several callouts describing the functions of each entity and the interfaces. The Non-Real Time RIC callout lists: Long term monitoring of RAN slice subnets performance, Retrieval of target RAN slice SLA/requirements, and Non-RT O1 re-configuration / A1 policies for slice assurance. The Near-RT RIC callout lists: Near real-time monitoring of RAN slice subnets performance and Optimized RAN (E2) actions to achieve RAN slice SLA based on O1 config, A1 policy, and E2 observations. The E2 Nodes callout lists: E2 REPORT (Fine-grained statistics) and E2 CONTROL/POLICY (Slice assurance actions, Slice resource allocation/prioritization). The O1 interface callout lists: Default/static/non-rt configuration and Counters/KPIs from near-RT RIC and E2 nodes. The A1 interface callout lists: A1 POLICY (Dynamic & optimized) and Policies for dynamic slice SLA assurance. The E2 interface callout lists: E2 CONTROL/POLICY (Slice assurance actions, Slice resource allocation/prioritization).](2f921f74be7ec0cd4b940269afdfae04_img.jpg) + +Figure 5.3.1-1: RAN slice SLA assurance use case overview. The diagram shows the interaction between the Service, Management & Orchestration Framework (SMO), Non-Real Time RIC, Near-RT RIC, and E2 Nodes. The SMO (orange box) contains the Non-Real Time RIC (green box) and the Near-RT RIC (blue box). The Non-Real Time RIC is connected to the Near-RT RIC via the A1 interface. The Near-RT RIC is connected to the E2 Nodes (grey box) via the E2 interface. The Non-Real Time RIC is also connected to the E2 Nodes via the O1 interface. The diagram includes several callouts describing the functions of each entity and the interfaces. The Non-Real Time RIC callout lists: Long term monitoring of RAN slice subnets performance, Retrieval of target RAN slice SLA/requirements, and Non-RT O1 re-configuration / A1 policies for slice assurance. The Near-RT RIC callout lists: Near real-time monitoring of RAN slice subnets performance and Optimized RAN (E2) actions to achieve RAN slice SLA based on O1 config, A1 policy, and E2 observations. The E2 Nodes callout lists: E2 REPORT (Fine-grained statistics) and E2 CONTROL/POLICY (Slice assurance actions, Slice resource allocation/prioritization). The O1 interface callout lists: Default/static/non-rt configuration and Counters/KPIs from near-RT RIC and E2 nodes. The A1 interface callout lists: A1 POLICY (Dynamic & optimized) and Policies for dynamic slice SLA assurance. The E2 interface callout lists: E2 CONTROL/POLICY (Slice assurance actions, Slice resource allocation/prioritization). + +**Figure 5.3.1-1: RAN slice SLA assurance use case overview** + +The more detailed functions provided by the entities for RAN slice SLA assurance are listed as below: + +- 1) SMO: + - a) Provides information about slice topology and SLA associated with the slice to the Non-RT RIC +- 2) Non-RT RIC: + - a) Retrieve RAN slice SLA target from respective entities such as SMO, NSSMF + - b) Long term monitoring of O-RAN slice subnet performance measurements + - c) Training of potential ML models that will be deployed in Near-RT RIC for optimized slice assurance + - d) Support deployment and update of AI/ML models into Near-RT RIC + - e) Send A1 policies and enrichment information to Near-RT RIC to drive slice assurance + - f) Send O1 reconfiguration requests to SMO for slow-loop slice assurance +- 3) Near-RT RIC: + - a) Near-real-time monitoring of slice specific RAN performance measurements + - b) Support deployment and execution of the AI/ML models from Non-RT RIC + - c) Support interpretation and execution of policies from Non-RT RIC + - d) Perform optimized RAN (E2) actions to achieve O-RAN slice subnet requirements based on O1 configuration, A1 policy, and E2 reports +- 4) E2 Nodes (O-CU-CP, O-CU-UP, O-DU): + - a) Support slice assurance actions such as slice-aware resource allocation, prioritization, etc. + - b) Support slice specific performance measurements through O1 + - c) Support slice specific performance reports through E2 + +### 5.3.2 Use case 2: Multi-vendor slices + +This use case enables multiple slices with functions provided by multi-vendors, such as slice #1, composed of DU(s) and CU(s), provided by vendor B and slice #2, composed of DU(s) and CU(s), provided by vendor C (see figure 5.3.2-1). + +![Figure 5.3.2-1: Multi-vendor slices architecture diagram. The diagram shows an O-RU connected to two O-Clouds. The first O-Cloud contains vO-DU and vO-CU-UP functions, while the second contains vO-CU-CP and vO-CU-UP functions. A 5G Core is connected to both O-Clouds. Two slices are defined: Slice #1 (eMBB) and Slice #2 (URLLC). A legend identifies RAN Vendor A (yellow), RAN Vendor B (blue), and RAN Vendor C (green). Interfaces shown include F1-C, F1-U, F1, NG-U, NG-C, and NG-J.](8fbab6b4bfe88dcbd4a63361edac7408_img.jpg) + +Figure 5.3.2-1: Multi-vendor slices architecture diagram. The diagram shows an O-RU connected to two O-Clouds. The first O-Cloud contains vO-DU and vO-CU-UP functions, while the second contains vO-CU-CP and vO-CU-UP functions. A 5G Core is connected to both O-Clouds. Two slices are defined: Slice #1 (eMBB) and Slice #2 (URLLC). A legend identifies RAN Vendor A (yellow), RAN Vendor B (blue), and RAN Vendor C (green). Interfaces shown include F1-C, F1-U, F1, NG-U, NG-C, and NG-J. + +**Figure 5.3.2-1: Multi-vendor slices** + +When providing multiple slices, it is assumed that suitable virtualized O-DU (vO-DU)/scheduler and virtualized O-CU-CP and virtualized O-CU-UP treat each slice respectively. A vendor who provides vO-DU and vO-CU-UP function may include a customized scheduler for a certain service, with advantages for optimized functionality. With accomplishment of multi-vendor circumstances, following benefits may be expected: + +#### 1) More flexible and time to market deployment + +Operators can maximize options to choose suitable vO-DU/scheduler and vO-CU-CP and vO-CU-UP to offer various slices. For example, some vendors may have an optimized scheduler for eMBB services and the other may have an optimized scheduler for URLLC services. Or, vendor A can provide vO-DU/scheduler and vO-CU-CP and vO-CU-UP suitable for URLLC earlier than vendor B, therefore operators can choose vO-DU and vO-CU-CP and vO-CU-UP functions from vendor A to meet their service requirements. + +Also, when an operator wants to add a new service/slice, new functions from a new vendor can be introduced with less consideration for existing vendors if multi-vendor circumstance was realized. This can help expand vendor's business opportunities rapidly. + +#### 2) Flexible deployment when sharing RAN equipment among operators + +When operators want to share RAN equipment and resources, RAN vendors and their placement of each RAN functions can be different. If multi-vendor circumstance was introduced, then it can relax restrictions among operators to share RAN equipment and resources. This can help expanded opportunities for reaching agreements of RAN sharing among operators. With expansion of RAN sharing, operators CAPEX and OPEX can be optimized, helping with additional investment opportunities. + +#### 3) Reducing supply chain risk + +If an existing vendor providing a certain pair of vO-DU and vO-CU-CP and vO-CU-UP functions withdraws of the market due to business reasons, operators can deploy new vO-DU and vO-CU-CP and vO-CU-UP functions alternatively from other vendors under this multi-vendor circumstance. This can reduce the risk for operators' business continuity. + +To realise multi-vendor slices, some coordination between vO-DU/vO-CU-CP/vO-CU-UPs is required since radio resources shall be assigned properly and without any conflicts. Depending on different service goals and the potential impact on O-RAN architecture, a required coordination scheme needs to be determined. The possible cases are: + +- 1) Loose coordination through O1/E2/A1 interface (case 1 shown in figure 5.3.2-2) +- 2) Moderate coordination through X2/F1 interface (case 2 shown in figure 5.3.2-2) +- 3) Tight coordination through a new interface between vO-DUs (case 3 shown in figure 5.3.2-2) + +![Figure 5.3.2-2: Multi-vendor slices coordination scheme options. The diagram shows three cases of multi-vendor slice coordination. Case 1 (O1/E2/A1 IF) shows a loose coordination where the SMO (Non-RT RIC, Near-RT RIC) connects to the O-CU and O-DU via O1, E2, and A1 interfaces. Case 2 (X2/F1 IF) shows a tight coordination where the SMO connects to the O-CU via O1, E2, and A1, and the O-CU connects to the O-DU via X2 and F1. Case 3 (New IF) shows a tight coordination where the SMO connects to the O-CU via O1, E2, and A1, and the O-CU connects to the O-DU via a new interface (New IF). The diagram also shows the O-RU and RAN Vendor A/B components.](328cb1933c827aa95fb7090375a16d04_img.jpg) + +Figure 5.3.2-2: Multi-vendor slices coordination scheme options. The diagram shows three cases of multi-vendor slice coordination. Case 1 (O1/E2/A1 IF) shows a loose coordination where the SMO (Non-RT RIC, Near-RT RIC) connects to the O-CU and O-DU via O1, E2, and A1 interfaces. Case 2 (X2/F1 IF) shows a tight coordination where the SMO connects to the O-CU via O1, E2, and A1, and the O-CU connects to the O-DU via X2 and F1. Case 3 (New IF) shows a tight coordination where the SMO connects to the O-CU via O1, E2, and A1, and the O-CU connects to the O-DU via a new interface (New IF). The diagram also shows the O-RU and RAN Vendor A/B components. + +**Figure 5.3.2-2: Multi-vendor slices coordination scheme options** + +In case 1, a resource allocation between slices or vO-DU/vO-CU-CP/vO-CU-UPs shall be provisioned through O1/A1/E2 interface, and each pair of vO-DU and vO-CU will allocate radio resources to each customer within radio resources allocated by Near-RT RIC and/or Non-RT RIC. + +In case 2, a resource allocation may be negotiated between slices or vO-DU/vO-CU-CP/vO-CU-UPs through X2 and F1 after provisioned through O1/E2/A1 interface. Negotiation period will be several seconds due to periodicity of X2 and F1 message exchange between vO-CU-CP(s). + +If a more adaptive radio resource allocation is needed (case 3), more frequent negotiation would be required. This may potentially be achieved via an interface or API extension between vO-DU(s). + +### 5.3.3 Use case 3: O-NSSI resource allocation optimization + +5G networks are becoming increasingly complex with the densification of millimeter wave small cells, and various new services, such as eMBB (enhanced Mobile Broadband), URLLC (Ultra Reliable Low Latency Communications), and mMTC (massive Machine Type Communications) that are characterized by high speed high data volume, low speed ultra-low latency, and infrequent transmitting low data volume from huge number of emerging smart devices, respectively. It is a challenging task for 5G networks to allocate resources dynamically and efficiently among multiple network nodes to support various services. However, eMBB, URLLC, and mMTC services in 5G are typically realized as NSI(s) (Network Slice instance(s)). Therefore, the resources allocated to O-NSSI (O-RAN Network Slice Subnet Instance) to support the O-RAN nodes can be optimized according to the service requirements. + +As the new 5G services have different characteristics, the network traffic tends to be sporadic, where there can be different usage pattern in terms of time, location, UE distribution, and types of applications. For example, most IoT sensor applications may run during off-peak hours or weekends. Special events, such as sport games, concerts, can cause traffic demand to shoot up at certain times and locations. Therefore, O-NSSI resource allocation optimization function trains the AI/ML model, based on the huge volume of performance data collected over days, weeks, months from O-RAN nodes. It then uses the AI/ML model to predict the traffic demand patterns of 5G networks in different times and locations for each network slice subnet, and automatically re-allocates the network resources ahead of the network issues surfaced. + +The resource quota policies associated with RAN NFs (E2 Nodes) included in the respective O-NSSIs enable 5G network providers to optimize or prioritize the utilization of the RAN resources across slices and supports the flexibility to share resources optimally across critical service slices during resource surplus or scarcity. For example, an O-NSSI allocated for premium service can receive a major share of the resources compared to a slice allocated for a standard/best-effort service. Another such example is the scenario of additional resource allocation for emergency services. An important consideration here is that the O-NSSI resource quota policies focuses on maximization of resource utilization across the O-NSSIs. The resource quota policies can be used as a constraint for resource allocation that defines the range of resources that can be allocated per slice. One use case for applying such a constraint is the analysis and decision based on history of resource allocation failure that may be reflected in the RAN node measurements. Here resource quota policy can be provisioned to control the minimum, maximum and dedicated resources that need to be allocated based on the historical + +pattern. The O-NSSI resource allocation optimization on the Non-RT RIC is shown in figure 5.3.3-1 shows, and may consist of the following steps: + +1. Monitoring: monitor the radio network(s) by collecting data via the O1 interface, including the following performance measurements that are measured per S-NSSAI (3GPP TS 28.552 [8] shall apply): + - DL PRB used for data traffic (3GPP TS 28.552 [8], clause 5.1.1.2.5 shall apply) + - UL PRB used for data traffic (3GPP TS 28.552 [8], clause 5.1.1.2.7 shall apply) + - Average DL UE throughput in gNB (3GPP TS 28.552 [8], clause 5.1.1.3.1 shall apply) + - Average UL UE throughput in gNB (3GPP TS 28.552 [8], clause 5.1.1.3.3 shall apply) + - Number of PDU sessions requested to setup (3GPP TS 28.552 [8], clause 5.1.1.5.1 shall apply) + - Number of PDU sessions successfully setup (3GPP TS 28.552 [8], clause 5.1.1.5.2 shall apply) + - Distribution of DL UE throughput in gNB (3GPP TS 28.552 [8], clause 5.1.1.3.2 shall apply) + - Distribution of UL UE throughput in gNB (3GPP TS 28.552 [8], clause 5.1.1.3.4 shall apply) + - Number of DRBs successfully setup (3GPP TS 28.552 [8], clause 5.1.1.10.2 shall apply) +2. Analysis & Decision: consisting of the following steps: + - o Utilize AI/ML models to analyze the measurements and predict the future traffic demand, including the RRMPolicyRatio IOC limits, for each O-NSSI for a given time and location. + - o Determine the actions needed to add or reduce the resources (e.g. capacity, VNF resources, slice subnet attributes (3GPP TS 28.541 [7] shall apply), etc.) for the RAN NFs (E2 Nodes) included in the respective O-NSSI at the given time, and location. +3. Execution: execute the following actions to reallocate the O-NSSI resources: + - 3a. Re-configure the O-NSSI attributes, including RRMPolicyRatio IOCs (3GPP TS 28.541 [7] shall apply) via the OAM functions in SMO which uses O1 interface to configure the E2 Nodes. + - 3b. Update the cloud resources via the O2 interface + +![Figure 5.3.3-1: The realization of O-NSSI resource allocation optimization over Non-Real Time RIC. The diagram shows a hierarchical architecture. At the top is the 'Service management & Orchestration Framework' containing the 'Non-RT RIC' (with 'NSSI Resource Allocation Optimization') and 'O-Cloud M&O'. The Non-RT RIC performs three main steps: 1. monitoring, 2. analysis & decision, and 3.b execution. It interacts with the 'Near-RT RIC' via the A1 interface. The Near-RT RIC interacts with 'Network functions' (O-CU-UP, O-CU-CP, O-DU, O-RU) via E2 interfaces. The Network functions interact with the 'O-Cloud' via the Open Fronthaul interface (F1-U, F1-C). The O-Cloud M&O interacts with the O-Cloud via the O2 interface. The O-Cloud M&O also performs 3.a. execution and 3.b execution steps.](6b17577390ea3a6abcb5725e8ba87d1d_img.jpg) + +Figure 5.3.3-1: The realization of O-NSSI resource allocation optimization over Non-Real Time RIC. The diagram shows a hierarchical architecture. At the top is the 'Service management & Orchestration Framework' containing the 'Non-RT RIC' (with 'NSSI Resource Allocation Optimization') and 'O-Cloud M&O'. The Non-RT RIC performs three main steps: 1. monitoring, 2. analysis & decision, and 3.b execution. It interacts with the 'Near-RT RIC' via the A1 interface. The Near-RT RIC interacts with 'Network functions' (O-CU-UP, O-CU-CP, O-DU, O-RU) via E2 interfaces. The Network functions interact with the 'O-Cloud' via the Open Fronthaul interface (F1-U, F1-C). The O-Cloud M&O interacts with the O-Cloud via the O2 interface. The O-Cloud M&O also performs 3.a. execution and 3.b execution steps. + +**Figure 5.3.3-1: The realization of O-NSSI resource allocation optimization over Non-Real Time RIC** + +The more detailed functions provided by the entities for O-NSSI resource optimization are listed as follows: + +- 1) SMO: + - a) Pre-provision the default O-NSSI resource quota policy as constraint for O-NSSI resource allocation optimization. This information is optionally used by the Non-RT RIC in case the resource quota that needs to be allocated per slice is not specified during the slice creation and for conflict resolution at the time of resource scarcity. +- 2) Non-RT RIC: + - a) Collect the performance measurements related to O-NSSI resource usage from the O-RAN nodes via the O1 interface. + - b) Train the AI/ML model based on the analysis of historical performance measurements, to predict of the traffic demand patterns of O-NSSI at different times and locations. + - c) Determine the time/date and locations (i.e. which O-RAN nodes) to add or reduce the resources (e.g. capacity, VNF resources, slice subnet attributes (3GPP TS 28.541 [7]), RRMPolicyRatio IOC, etc.) for a given O-NSSI based on inference. + - d) Perform the following action(s) to optimize the O-NSSI resource allocation, at the time determined by the model + - i. Re-configure the O-NSSI attributes via the O1 interface. + - ii. Update the cloud resources via the O2 interface. +- 3) E2 Nodes (O-CU-CP, O-CU-UP, O-DU, and O-RU): + - a) Support the performance measurement collection with required granularity over O1 interface. + - b) Support the configuration related to the O-NSSI resource allocation update over O1 interface. + +# 6 O-RAN slicing principles and requirements + +## 6.1 General principles + +This clause contains general O-RAN slicing architecture principles as described below: + +- O-RAN slicing architecture and interface specifications shall be consistent with 3GPP architecture and interface specifications to the extent possible +- O-RAN slicing architecture shall provide standardized management service interfaces for O-RAN slice management services +- O-RAN slicing architecture shall enable multi-vendor interoperability +- O-RAN slicing architecture shall support multiple different network operator deployment options +- O-RAN slicing architecture shall support management of O-RAN slice subnets in multi-operator scenarios + +## 6.2 Slicing requirements + +### 6.2.1 Functional requirements + +Initial set of O-RAN slicing functional requirements based on the use cases defined in the present document is captured in table 6.2.1-1. + +**Table 6.2.1-1: O-RAN slicing functional requirements** + +| REQ | Description | Note | +|---------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------| +| [REQ-SL-FUN1] | O-RAN slicing architecture and interfaces shall support network slicing, where an instance of O-RAN network function may be associated with one or more slices. | ORAN OAM Specification v02.00 | +| [REQ-SL-FUN2] | O-RAN slicing architecture shall support differentiated handling of traffic for different O-RAN slice subnets. | 3GPP TS 38.300 | +| [REQ-SL-FUN3] | O-RAN slicing architecture shall support resource isolation between slices. | 3GPP TS 38.300 | +| [REQ-SL-FUN4] | O-RAN slicing architecture shall enable traffic and services in one O-RAN slice subnet having no impact on traffic and services in other O-RAN slice subnets in the same network. | 3GPP TS 22.261 | +| [REQ-SL-FUN5] | O-RAN slicing architecture shall enable mechanisms to avoid shortage of shared resources in one slice breaking the service level agreement for another slice. | 3GPP TS 38.300 | +| [REQ-SL-FUN6] | O-RAN slicing architecture shall enable defining a priority order between different O-RAN slice subnets in case multiple slices compete for resources on the same RAN. | 3GPP TS 22.261 | +| [REQ-SL-FUN7] | O-RAN slicing architecture shall apply policies at S-NSSAI level according to the SLA required by the network slice. | - | +| [REQ-SL-FUN8] | O-RAN slicing architecture shall support means by which the operator can differentiate policy control, functionality and performance provided in different O-RAN slice subnets. | 3GPP TS 22.261 | + +| REQ | Description | Note | +|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------| +| [REQ-SL-FUN9] | O-RAN slicing architecture shall support QoS differentiation within a slice. | 3GPP TS 38.300 | +| [REQ-SL-FUN10] | O-RAN slicing architecture shall enable slice aware radio resource management strategies (such as admission control, congestion control, handover preparation). | 3GPP TS 38.300 | +| [REQ-SL-FUN11] | O-RAN slicing architecture shall allow creation, modification, and deletion of an O-RAN slice subnet. | 3GPP TS 28.531 | +| [REQ-SL-FUN12] | O-RAN slicing architecture shall support interaction between the SMO framework and Non-RT RIC to consume provisioning management services exposed by each O-RAN managed element to configure O-RAN slice subnets through the O1 interface. | RAN slice SLA assurance use case, O-NSSI resource allocation optimization use case | +| [REQ-SL-FUN13] | O-RAN slicing architecture shall support the interaction between the SMO framework and Non-RT RIC to consume management of slice specific PM jobs, PM data collection/storage/query/statistical reports from O-RAN network functions through the O1 interface. | RAN slice SLA assurance use case, O-NSSI resource allocation optimization use case | +| [REQ-SL-FUN14] | O-RAN slicing architecture shall support interaction between the SMO framework and Non-RT RIC to retrieve/notify O-RAN slice subnet requirements (SLA) along with O-NSSI information. | RAN slice SLA assurance use case, O-RAN slice subnet instance creation use case | +| [REQ-SL-FUN15] | O-RAN slicing architecture shall support provisioning, generation, and monitoring of slice specific RAN performance metrics through O1 interface. | RAN slice SLA assurance use case, O-NSSI resource allocation optimization use case | +| [REQ-SL-FUN16] | O-RAN slicing architecture shall support training, deployment, and execution of AI/ML models for slice SLA assurance and O-NSSI resource allocation optimization. | RAN slice SLA assurance use case, O-NSSI resource allocation optimization use case | +| [REQ-SL-FUN17] | O-RAN slicing architecture shall support slice specific policy guidance, enrichment information and policy feedback. | RAN slice SLA assurance use case | +| [REQ-SL-FUN18] | O-RAN slicing architecture shall support provisioning, generation, and monitoring of slice specific RAN performance data through E2 interface. | RAN slice SLA assurance use case | +| [REQ-SL-FUN19] | O-RAN slicing architecture shall support reconfiguration of slice specific RAN parameters and resources for slice SLA assurance. | RAN slice SLA assurance use case | +| [REQ-SL-FUN20] | O-RAN slicing architecture shall enable creation of O-RAN network slice subnet instances as O-RAN network service (NS) instance(s) within O-Cloud(s). | O-RAN slice subnet instance creation use case | +| [REQ-SL-FUN21] | O-RAN slicing architecture shall enable association and disassociation of O-Cloud NS instances with corresponding O-NSSIs. | O-RAN slice subnet instance creation use case, O-RAN slice subnet instance termination use case | +| [REQ-SL-FUN22] | O-RAN slicing architecture shall enable creation of O-RAN network slice subnet instances as O-RAN network function (NF) instance(s) within O-Cloud(s). | O-RAN slice subnet instance creation use case | +| [REQ-SL-FUN23] | O-RAN slicing architecture shall enable association and disassociation of O-Cloud NF instances with corresponding O-NSSIs. | O-RAN slice subnet instance creation use case, O-RAN slice subnet | + +| REQ | Description | Note | +|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------| +| | | instance termination use case | +| [REQ-SL-FUN24] | O-RAN slicing architecture shall support (re-)configuration of an O-NSSI's constituent network functions through the O1 interface. | O-RAN slice subnet instance creation use case, O-RAN slice subnet modification use case, O-RAN slice subnet configuration use case | +| [REQ-SL-FUN25] | O-RAN slicing architecture shall support (re-)configuration of an O-RAN network slice subnet instance (O-NSSI) attributes. | O-RAN slice subnet instance creation / activation / modification / deactivation / configuration use case | +| [REQ-SL-FUN26] | O-RAN slicing architecture shall have the capability for the establishment of required transport network connectivity between O-RAN NFs during provisioning of O-RAN network slice subnet instances. | O-RAN slice subnet instance creation use case, O-RAN slice subnet instance modification use case | +| [REQ-SL-FUN27] | O-RAN slicing architecture shall enable Non-RT RIC to be notified when an O-NSSI has been created, activated, modified, deactivated and terminated. | O-RAN slice subnet instance creation use case, O-RAN slice subnet instance modification use case, O-RAN slice subnet instance termination use case | +| [REQ-SL-FUN28] | O-RAN slicing architecture shall support the capability to activate the constituent physical network functions such as O-DU and O-RU within an O-NSSI. | O-RAN slice subnet instance activation use case | +| [REQ-SL-FUN29] | O-RAN slicing architecture shall enable modification of O-RAN network slice subnet instances through modification (such as scaling, updating, instantiation, etc.) of O-RAN network service (NS) instance(s) within O-Cloud(s). | O-RAN slice subnet instance modification use case | +| [REQ-SL-FUN30] | O-RAN slicing architecture shall enable modification of O-RAN network slice subnet instances through modification (such as scaling, updating, instantiation, etc.) of O-RAN network function (NF) instance(s) within O-Cloud(s). | O-RAN slice subnet instance modification use case | +| [REQ-SL-FUN31] | O-RAN slicing architecture shall support the capability to deactivate the constituent physical network functions such as O-DU and O-RU within an O-NSSI. | O-RAN slice subnet instance deactivation use case | +| [REQ-SL-FUN32] | O-RAN slicing architecture shall enable removal of constituent O-RAN network service (NS) instance(s) that were functioning within O-Cloud(s) and were associated to O-RAN network slice subnet instance(s). | O-RAN slice subnet instance termination use case | +| [REQ-SL-FUN33] | O-RAN slicing architecture shall enable removal of constituent O-RAN network function (NF) instance(s) that were functioning within O-Cloud(s) and were associated to O-RAN network slice subnet instance(s). | O-RAN slice subnet instance termination use case | +| [REQ-SL-FUN34] | O-RAN slicing architecture shall have the capability for the removal of non-shared transport network connectivity between O-RAN NFs during termination of O-RAN network slice subnet instances. | O-RAN slice subnet instance termination use case | +| [REQ-SL-FUN35] | O-RAN slicing architecture shall enable reservation of O-RAN network service (NS) instance(s) within O-Cloud(s). | O-RAN slice subnet feasibility check | + +| REQ | Description | Note | +|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------| +| [REQ-SL-FUN36] | O-RAN slicing architecture shall enable reservation of O-RAN network service (NF) instance(s) within O-Cloud(s). | O-RAN slice subnet feasibility check | +| [REQ-SL-FUN37] | O-RAN slicing architecture shall enable retrieval of network utilization information from the SMO and Non-RT RIC (e.g., load level information, resource usage information from management data analytics services). | O-RAN slice subnet feasibility check | +| [REQ-SL-FUN38] | O-RAN slicing architecture shall support interaction between the SMO framework and Non-RT RIC to consume O-Cloud management and orchestration services through the O2 interface. | RAN slice SLA assurance use case, O-NSSI resource allocation optimization use case | +| [REQ-SL-FUN39] | O-RAN slicing architecture shall enable provisioning and management of multiple slices on O-RU. | Multi-vendor slices use case | +| [REQ-SL-FUN40] | O-RAN slicing architecture shall enable O-RU to route per slice user plane traffic to one or more O-Dus. | Multi-vendor slices use case | + +### 6.2.2 Non-functional requirements + +Initial set of O-RAN slicing non-functional requirements based on the use cases defined in the present document is captured in table 6.2.2-1. + +**Table 6.2.2-1: O-RAN slicing non-functional requirements** + +| REQ | Description | Note | +|----------------|-------------------------------------------------------------------------------------------|------| +| [REQ-SL-NFUN1] | O-RAN slicing architecture shall support use of AI/ML to support O-RAN slicing use cases. | | + +# 7 O-RAN reference slicing architecture + +## 7.1 O-RAN reference slicing architecture + +This clause provides O-RAN reference slicing architecture (see figure 7.1-1) along with the high-level roles and responsibilities of O-RAN network functions. + +![Figure 7.1-1: O-RAN reference slicing architecture diagram. The diagram shows a hierarchical architecture. At the top is the 'Service and Management Orchestration Framework' (SMO) in a purple box, containing 'Slice Management Functions', 'Non-RT RIC', and 'Other SMO Functions'. Below SMO is the 'Near-RT RIC' in a blue box. The Near-RT RIC connects to 'O-CU-CP' and 'O-CU-UP' (yellow boxes) via E2 interfaces. O-CU-CP and O-CU-UP connect to 'O-DU' (red box) via E1 and E1-U interfaces. O-DU connects to 'O-RU' (red box) via 'Open Fronthaul'. O-RU connects to 'O-Cloud' (green box) via 'Open Fronthaul M-Plane'. Interfaces O1, A1, and O2 are shown as dashed lines connecting the SMO layer to the other components.](be5b6e4083a92d22f57cd9adacf2649e_img.jpg) + +Figure 7.1-1: O-RAN reference slicing architecture diagram. The diagram shows a hierarchical architecture. At the top is the 'Service and Management Orchestration Framework' (SMO) in a purple box, containing 'Slice Management Functions', 'Non-RT RIC', and 'Other SMO Functions'. Below SMO is the 'Near-RT RIC' in a blue box. The Near-RT RIC connects to 'O-CU-CP' and 'O-CU-UP' (yellow boxes) via E2 interfaces. O-CU-CP and O-CU-UP connect to 'O-DU' (red box) via E1 and E1-U interfaces. O-DU connects to 'O-RU' (red box) via 'Open Fronthaul'. O-RU connects to 'O-Cloud' (green box) via 'Open Fronthaul M-Plane'. Interfaces O1, A1, and O2 are shown as dashed lines connecting the SMO layer to the other components. + +**Figure 7.1-1: O-RAN reference slicing architecture** + +O-RAN reference slicing architecture includes slice management functions along with O-RAN architectural components. As O-RAN's general principle is to be as compliant as possible with 3GPP architecture, these slice management functions are 3GPP-defined NSMF and NSSMF with extensions defined for O-RAN network functions. Various deployment options for the location of NSMF(s) and NSSMF(s) are included in [i.4]. Detailed architectural implementation options for SMOs including NFV-MANO and ONAP are being presented in Appendix A of this document. + +## 7.2 Non-RT RIC + +The fundamental role of the Non-RT RIC in O-RAN slicing architecture is to gather long term slice related data through interaction with the SMO framework and apply AI/ML based approaches interworking with the Near-RT RIC to provide innovative RAN slicing use cases. For this purpose, Non-RT RIC shall have the knowledge of O-RAN slice subnets and their respective SLA(s) through SMO. In addition, Non-RT RIC may retrieve enrichment information from 3rd party applications and use that information for RAN slice SLA assurance purposes. + +In order to construct AI/ML models to be deployed in the Near-RT RIC, Non-RT RIC shall retrieve slice specific performance metrics, configuration parameters and required attributes of the O-RAN slice subnets from the SMO framework. The output of these algorithms may lead non-real-time optimization of the slice specific parameters of Near-RT RIC, O-CU-CP, O-CU-UP and O-DU over O1 interface through SMO interaction. Moreover, these performance, configuration and other slice related data are used to generate policy guidance and assist Near-RT RIC over A1 to provide + +closed loop slice optimization. Applying such slice optimizations in the Near-RT RIC may be used for SLA assurance and prevent SLA violations between the slices as well. + +## 7.3 Near-RT RIC + +Near-RT RIC enables near-real-time O-RAN slice subnet optimization through execution of slicing-related xApps and communicating necessary parameters to O-CU-CP, O-CU-UP and O-DU through E2 interface. Deployed xApps may utilize either AI/ML based models or non-AI/ML algorithms which may further be guided by A1 policies that are generated by Non-RT RIC. + +In order to drive sliced RAN resources properly, Near-RT RIC shall have the knowledge of existing O-RAN slice subnets as well as their SLA requirements. This information will be received through O1 interface during provisioning of O-RAN slice subnets. Therefore, similar to Non-RT RIC, Near-RT RIC will be aware of O-RAN slice subnets through O-RAN specific information models and provisioning procedures. + +In O-RAN slicing architecture, configuration of slice resources on E2 nodes can be achieved through slow loop with O1 configuration and through fast loop with E2 configuration. This architecture enables advanced slicing use cases such as RAN slice SLA assurance and further enhances 3GPP slicing capability without misalignment. In the context of the RAN, the SLA assurance parameters sent over the A1 interface assist the Near-RT RIC guide the behavior of the E2 Nodes (O-CU-UP, O-CU-CP, O-DU). While Near-RT RIC is capable for fast-loop configuration, slicing related O1 configuration, such as RRM policy information sent to O-CU-CP, O-CU-UP and O-DU configured by the SMO framework will be taken into account. Moreover, slice-specific near-real-time performance data shall be monitored through E2 interface which needs proper PM mechanisms between E2 nodes and Near-RT RIC as well. + +## 7.4 O-RAN Central Unit (O-CU-CP, O-CU-UP) + +O-CU-CP and O-CU-UP need to support slicing features as defined by 3GPP. Depending on slice requirements, O-CU-UP may be shared across slices or a specific instance of O-CU-UP may be instantiated per slice. On top of 3GPP slicing features, O-RAN further enhances slicing through the utilization of E2 interface and the assistance of Near-RT RIC dynamic slice optimizations along with the enhanced O1 interface to support additional slice configuration parameters. + +O-CU-CP and O-CU-UP stacks, which are the upper layer protocols of the RAN stack, shall be slice aware and execute slice specific resource allocation and isolation strategies. These stacks are initially configured through O1 interface based on the slice specific requirements and then dynamically updated through E2 interface via Near-RT RIC for various slicing use cases. + +Based on the PM requests from SMO and Near-RT RIC, O-CU-CP and O-CU-UP shall generate and send specific PMs through O1 and E2 interfaces respectively, where the PMs may be used for slice performance monitoring and slice SLA assurance purposes. + +## 7.5 O-RAN Distributed Unit (O-DU) + +O-DU, which runs the lower layer protocols of RAN stack, shall support slice specific resource allocation strategies as well. Based on the initial O1 configuration of PRB allocation levels along with O-CU-CP and O-CU-UP directives over F1 interface and the dynamic guidance received from Near-RT RIC over E2 interface, MAC layer needs to allocate and isolate relevant PRBs to specific slices. + +Based on the PM requests from SMO and Near-RT RIC, O-DU shall generate and send specific PMs through O1 and E2 interfaces respectively, where the PMs may be used for slice performance monitoring and slice SLA assurance purposes. + +## 7.6 A1 interface + +A1, which is the interface between the Non-RT RIC and the Near-RT RIC, supports policy management, ML model management and enrichment information services [i.13]. These three services will be utilized for various slicing use cases, such as slice SLA assurance. Policy management will be used by Non-RT RIC to send slice specific (e.g. S-NSSAI based) policies to guide Near-RT RIC with slice resource allocations and slice specific control activities, as well as to receive slice specific policy feedback for the policies deployed on the Near-RT RIC. + +For the use cases that make use of external enrichment data or where Non-RT RIC produces enrichment information, A1 enrichment interface will be used to send slice specific enrichment data to Near-RT RIC. + +It should be noted that slice specific A1 policies are not persistent (do not survive the restart of Near-RT RIC) and while they may take precedence over O1 slice specific configurations, they should be aligned and not deviate significantly from O1 configurations. + +## 7.7 E2 interface + +E2, which is the interface between the Near-RT RIC and the E2 nodes, supports E2 primitives (report, insert, control and policy) to control the services exposed by E2 nodes [i.14]. These primitives will be used by slice specific applications (xApps) to drive E2 nodes' slice configurations and slice specific behaviour, such as slice based radio resource management, radio resource allocations, MAC scheduling policies and other configuration parameters used by various RAN protocol stacks. + +E2 will be used to configure and receive slice specific reports and performance data from E2 nodes. These reports may include 3GPP defined slice specific PMs (such as PRB utilization, average delay, etc. 3GPP TS 28.552 [8]) and new PMs that may be defined by O-RAN to support various slicing use cases. + +## 7.8 O1 interface + +O1, which is the interface between O-RAN managed elements and the management entity shall be used as specified in O-RAN.WG1.O1-Interface.0-v04.00 [13], to configure slice specific parameters of O-RAN nodes based on the service requirements of the slice. Some of the slice specific information models have been specified in 3GPP TS 28.541 [7], including the RRM policy attributes to provide the ratio of PRBs and the split of these PRBs among slices. To support O-RAN slicing use cases and their requirements, 3GPP information models may be extended and additional information models may be defined to capture slice profiles and slice specific configuration parameters, which will be carried over O1 interface as well. + +O1 will also be used to configure and gather slice specific performance metrics and slice specific faults from O-RAN nodes. + +## 7.9 O2 interface + +O2, which is the interface between the SMO and O-Cloud as introduced in [i.15], shall be used for life cycle management of virtual O-RAN network functions. As part of O-RAN NSSI creation and provisioning, RAN NSSMF, in interaction with SMO, triggers the instantiation of necessary O-RAN functions (such as Near-RT RIC, O-CU-CP, O-CU-UP and O-DU) based on slice requirements. After the creation of O-RAN NSSI, NSSMF in interaction with SMO may execute O-NSSI modification and O-NSSI deletion procedures. + +Since Non-RT RIC is part of SMO and would be instantiated along with other SMO functions, O2 is not expected to be used for lifecycle management of Non-RT RIC. + +## 7.10 Transport network slicing + +As O-RAN slice subnet is composed of not only the O-RAN NFs but also the transport network components; Fronthaul interface (FH) between O-RU and O-DU and the Midhaul interface (MH) between the O-DU and O-CU, transport slicing aspects needs to be considered and incorporated into the overall O-RAN slicing architecture. + +There are different emerging approaches for defining transport network slicing that can meet 5G requirements, which mobile interfaces (fronthaul and midhaul in O-RAN slice subnet, backhaul between O-RAN slice subnet and core slice subnet, and between core slice subnet and the PDN) may and need to be sliced, what form they will take and the number of slices required at the transport layer [i.16]. + +This clause aims to capture the transport network slicing aspects for fronthaul and midhaul links and provide references to relevant O-RAN specifications (related to fronthaul, intra-DC virtual links, inter-DC links). Given the current state and progress in these WGs, this version of the O-RAN Slicing Architecture Specification will focus only on transport network aspects, with the scope of the network segments covered by O-RAN as shown in figure 7.10-1. The area inside the dotted green line characterizes the transport networks composed of a number of Transport Network Elements (TNE) deployed among different components defined in other O-RAN WGs. O-RAN does not define the interfaces along the dotted green line. + +![Figure 7.10-1: Xhaul transport network overview. The diagram illustrates the transport network architecture, showing the flow from O-RU (Radio Units) through various interfaces (7.2x, eCPRI, F1, N2,N3) to the 5G Core (EPC). A dotted green line indicates the scope of WG9, which covers the transport network elements (TNE) and interfaces within this boundary. The diagram also shows the connection between the transport network and the core network (EPC) via the S1 interface. A red box at the top left indicates 'Outside of scope of WG9'.](f24058b554b0ae06b5af160beabbbb18_img.jpg) + +Outside of scope of WG9 + +Scope of WG9 is represented as the area inside the dotted green line. The interfaces along the dotted green lines are not defined by WG9. + +Rectangular elements denote logical functions. Actual physical product implementations may combine some of the functions on different sides of the dotted green lines. + +Solid lines in this diagram represent logical connections. Actual physical connections may be different. + +Figure 7.10-1: Xhaul transport network overview. The diagram illustrates the transport network architecture, showing the flow from O-RU (Radio Units) through various interfaces (7.2x, eCPRI, F1, N2,N3) to the 5G Core (EPC). A dotted green line indicates the scope of WG9, which covers the transport network elements (TNE) and interfaces within this boundary. The diagram also shows the connection between the transport network and the core network (EPC) via the S1 interface. A red box at the top left indicates 'Outside of scope of WG9'. + +**Figure 7.10-1: Xhaul transport network overview (ref: Figure 3-1 [i.16])** + +### Packet switched transport network slicing: + +O-RAN has defined the architecture and the best practices for an open Xhaul transport network based on an end-to-end packet switching architecture in “Xhaul Packet Switched Architectures and Solutions specification” [i.16] that may support the requirements outlined in O-RAN.WG9.XTRP-REQ-v01.00 [i.17]. While the “Xhaul Packet Switched Architectures and Solutions specification” [i.16] describes the best practices for O-RAN transport based on end-to-end packet switching technology, it is recognized that other solutions, not based on packet switching, could be utilized, or mixed with a packet switching solution as well. + +As indicated in clause 17 [i.16] the terms hard and soft slicing has emerged for transport networks, referring to the level of isolation between different slices: + +- Hard slicing: Transport resources are dedicated to a specific “Network Slice Instance” (NSI) and cannot be shared with other slices. +- Soft slicing: Transport resources are shared and may be re-used by other slices. + +A packet switched infrastructure, as described in [i.16], has an extensive toolset, consisting of underlay forwarding solutions, Quality of Service (QoS) and VPNs that allows an operator to scalable partition the transport network to cater for both hard and soft slices. Transport slice requirements and associated toolset are shown in figure 7.10-2. + +| | Isolation | Topology | Resources | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |

Image: Diagram showing five stacked VPN boxes labeled VPN1 (green), VPN2 (orange), VPN3 (red), VPN4 (blue), and VPN5 (grey).

|

Image: Diagram showing a physical topology with nodes and links, divided into three slices: Slice A (green), Slice B (orange), and Slice C (red). Each slice has its own network plane and low latency plane.

|

Image: Diagram showing a stack of four slices labeled Slice 1 (grey), Slice 2 (green), Slice 3 (orange), and Slice 4 (red). Each slice has its own set of links and resources.

| +| PURPOSE |
  • Traffic isolation between slices
|
  • Subset of physical topology
  • Low Latency slice
  • High Capacity slice
  • Plane A, Plane B slices
|
  • Resources
  • Links
  • Bandwidth
  • Queues/buffers
| +| TOOLSET |
  • L3VPN
  • EVPN L2 Services
  • VLANs
|
  • Intra-domain slicing architectures
  • SR Flexible Algorithms
  • SR Traffic Engineering
  • RSVP Traffic Engineering
  • Inter-domain slicing architectures
  • Seamless / redistribution
  • Controller based
|
  • Bandwidth Management with Call Admission Control
  • Dedicated components
  • Per-link slicing
  • Hierarchical QoS
  • Hierarchical Policers
| + +**Figure 7.10-2: Packet switched toolset for transport level slicing (ref: Figure 17-2 [i.16])** + +Further details of transport network slicing based on packet switching technology is captured in clause 17 and clause 18.10 of [i.16], including packet-switched underlay networks, transport network quality of service, 5G service and slices and a transport slicing scenario on a packet switched Xhaul network. + +# --- 8 O-RAN slice subnet provisioning procedures + +## 8.1 O-RAN Slice Subnet Instance (O-NSSI) allocation procedure + +The procedure for allocation of an O-RAN slice subnet instance to satisfy the O-NSSI requirements is given in figure 8.1-1. + +![Sequence diagram for O-NSSI allocation procedure. The diagram shows interactions between Slice Management Functions, NFO/FOCOM, OAM Functions, TN Management Functions, and Non-RT RIC. The process starts with '1 Allocate O-NSSI Request' from Slice Management Functions. It then references '2 O-NSSI Feasibility Check Procedure'. Step '3' is 'Decide to create a new O-NSSI or use an existing O-NSSI'. An 'alt' block follows: '[Using an existing O-NSSI]' references '4 Clause 6.2 O-NSSI Modification Procedure'; '[Create a new O-NSSI]' leads to '5 Derive the requirements for constituent O-NSSI(s) and transport network'. A 'loop' block '[For each O-NSSI constituent]' contains an 'alt' block: '[Constituent is an O-NSSI constituent]' references '6 Clause 6.1 O-NSSI Allocation Procedure'; '[Constituent is an O-RAN Network Function]' leads to 'Opt: If NF is virtual', which then leads to '7 Derive O-Cloud requirements for O-RAN NF', followed by '8 Establish virtual intra-Cloud links, allocate slice tags (i.e. VLAN ID) and optionally instantiate NF on O-Cloud (O-RAN.WG6.ORCH-USE-CASES Clause 3.10.1 Network Slice Creation)', then '9 Derive CM requirements for O-RAN NF', and finally '10 O-RAN.WG1.O1-Interface Clause 2.1 Provisioning Management Services'. After the loop, step '11 Configure O-NSSI MOI' is executed. Another 'loop' block '[For each transport network requirement]' leads to '12 Request transport link(s) across O-Clouds'. An 'Opt: If Non-RT RIC has subscribed for O-NSSI allocation event notifications' block leads to '13 Notification of Non-RT RIC with O-NSSI information'. Finally, '14 Allocate O-NSSI Response' is sent from Slice Management Functions.](7e80f89dc3442da696f373a347994dbb_img.jpg) + +``` + +sequenceDiagram + participant SMF as Slice Management Functions + participant NFO as NFO/FOCOM + participant OAM as OAM Functions + participant TNM as TN Management Functions + participant NonRT as Non-RT RIC + + SMF->>SMF: 1 Allocate O-NSSI Request + SMF->>SMF: ref 2 O-NSSI Feasibility Check Procedure + SMF->>SMF: 3 Decide to create a new O-NSSI or use an existing O-NSSI + alt [Using an existing O-NSSI] + SMF->>SMF: ref 4 Clause 6.2 O-NSSI Modification Procedure + else [Create a new O-NSSI] + SMF->>SMF: 5 Derive the requirements for constituent O-NSSI(s) and transport network + loop [For each O-NSSI constituent] + alt [Constituent is an O-NSSI constituent] + SMF->>SMF: ref 6 Clause 6.1 O-NSSI Allocation Procedure + else [Constituent is an O-RAN Network Function] + Opt: If NF is virtual + SMF->>SMF: 7 Derive O-Cloud requirements for O-RAN NF + SMF->>SMF: ref 8 Establish virtual intra-Cloud links, allocate slice tags (i.e. VLAN ID) and optionally instantiate NF on O-Cloud (O-RAN.WG6.ORCH-USE-CASES Clause 3.10.1 Network Slice Creation) + end + SMF->>SMF: 9 Derive CM requirements for O-RAN NF + SMF->>SMF: ref 10 O-RAN.WG1.O1-Interface Clause 2.1 Provisioning Management Services + end + end + SMF->>SMF: 11 Configure O-NSSI MOI + end + loop [For each transport network requirement] + SMF->>TNM: 12 Request transport link(s) across O-Clouds + end + Opt: If Non-RT RIC has subscribed for O-NSSI allocation event notifications + SMF->>NonRT: ref 13 Notification of Non-RT RIC with O-NSSI information + end + SMF->>SMF: 14 Allocate O-NSSI Response + +``` + +Sequence diagram for O-NSSI allocation procedure. The diagram shows interactions between Slice Management Functions, NFO/FOCOM, OAM Functions, TN Management Functions, and Non-RT RIC. The process starts with '1 Allocate O-NSSI Request' from Slice Management Functions. It then references '2 O-NSSI Feasibility Check Procedure'. Step '3' is 'Decide to create a new O-NSSI or use an existing O-NSSI'. An 'alt' block follows: '[Using an existing O-NSSI]' references '4 Clause 6.2 O-NSSI Modification Procedure'; '[Create a new O-NSSI]' leads to '5 Derive the requirements for constituent O-NSSI(s) and transport network'. A 'loop' block '[For each O-NSSI constituent]' contains an 'alt' block: '[Constituent is an O-NSSI constituent]' references '6 Clause 6.1 O-NSSI Allocation Procedure'; '[Constituent is an O-RAN Network Function]' leads to 'Opt: If NF is virtual', which then leads to '7 Derive O-Cloud requirements for O-RAN NF', followed by '8 Establish virtual intra-Cloud links, allocate slice tags (i.e. VLAN ID) and optionally instantiate NF on O-Cloud (O-RAN.WG6.ORCH-USE-CASES Clause 3.10.1 Network Slice Creation)', then '9 Derive CM requirements for O-RAN NF', and finally '10 O-RAN.WG1.O1-Interface Clause 2.1 Provisioning Management Services'. After the loop, step '11 Configure O-NSSI MOI' is executed. Another 'loop' block '[For each transport network requirement]' leads to '12 Request transport link(s) across O-Clouds'. An 'Opt: If Non-RT RIC has subscribed for O-NSSI allocation event notifications' block leads to '13 Notification of Non-RT RIC with O-NSSI information'. Finally, '14 Allocate O-NSSI Response' is sent from Slice Management Functions. + +Figure 8.1-1: O-NSSI allocation procedure + +- 1) Allocation request - Slice subnet management function receives an allocate O-NSSI request (AllocateNssi operation specified in 3GPP TS 28.531 [4], clause 6.5.2 shall apply) with network slice subnet related requirements (network slice subnet related requirements specified in SliceProfile in 3GPP TS 28.541 [7], clause 6.3.4 shall be used). +- 2) Feasibility check - Slice subnet management function checks the feasibility of O-RAN slice subnet related requirements utilizing O-NSSI feasibility check procedure (see clause 8.4). If the network slice subnet related requirements can be satisfied, the following steps are needed, else go to step 15. +- 3) O-NSSI decision - Based on the O-RAN slice subnet related requirements slice subnet management function decides whether to use an existing O-NSSI or create a new O-NSSI. +- 4) Modification procedure - If using an existing O-NSSI and the existing O-NSSI needs to be modified, slice subnet management function invokes the O-NSSI modification procedure. +- 5) Derive requirements - If creating a new O-NSSI, slice subnet management function creates the MOI for the O-NSSI to be created and then derives the corresponding O-RAN slice subnet constituent (i.e. O-RAN NF, constituent O-NSSI) related requirements and transport network related requirements from the received network slice subnet related requirements. + +For each required O-NSSI constituent, steps 6-11 are needed: + +- 6) Allocation procedure - If the required O-NSSI constituent is constituent O-NSSI, slice subnet management function invokes O-NSSI allocation procedure (clause 8.1). + +If the required O-NSSI constituent is a virtual O-RAN NF instance, steps 7-8 are needed: + +- 7) Derive requirements - Slice subnet management function derives O-Cloud requirements for O-RAN NF. +- 8) Instantiate/Scale NF - If the O-RAN NF is a virtual NF, slice subnet management function establishes virtual intra-Cloud links, allocates slice tags (i.e., VLAN ID) and optionally instantiates NF on O-Cloud by executing network slice creation as specified in O-RAN.WG6.ORCH-USE-CASES-v4.00 [18], clause 3.10.1. If an existing O-RAN virtual NF instance needs to be modified, slice subnet management function may execute Scale Out of NF as specified in O-RAN.WG6.ORCH-USE-CASES-v4.00 [18], clause 3.2.2, Scale In of NF as specified in O-RAN.WG6.ORCH-USE-CASES-v4.00 [18], clause 3.2.3. +- 9) CM requirements - Slice subnet management function derives CM requirements for O-RAN NF. +- 10) NF provisioning - Slice subnet management function executes provisioning management services as specified in O-RAN.WG1.O1-Interface.0-v4.00 [13], clause 2.1. +- 11) Configure O-NSSI - Slice subnet management function configures the O-NSSI MOI. + +For each transport network requirement, step 12 is needed: + +- 12) Transport link request - If the transport link is a physical link that needs to be established across clouds, slice subnet management function request transport link establishment from TN management functions. +- 13) Notification - If Non-RT RIC has subscribed for O-NSSI allocation event notifications, slice subnet management function notifies Non-RT RIC with O-NSSI information. +- 14) Allocation response - Slice subnet management function returns appropriate O-NSSI allocation result (AllocateNssi operation specified in 3GPP TS 28.531 [4], clause 6.5.2 shall apply). If the O-NSSI is created successfully, the result includes the relevant constituent network slice subnet instance information (NetworkSliceSubnet IOC specified in 3GPP TS 28.541 [7], clause 6.3.2 shall apply). + +## 8.2 O-RAN Slice Subnet Instance (O-NSSI) modification procedure + +The procedure for modification of an O-RAN slice subnet instance to satisfy the O-NSSI requirements is given in figure 8.2-1. + +![Sequence diagram for O-NSSI modification procedure. The diagram shows interactions between Slice Management Functions, NFO, OAM Functions, TN Management Functions, and Non-RT RIC. The process starts with a '1 Modify O-NSSI Request' from Slice Management Functions. It then proceeds to '2 Derive the modification requirements for the O-NSSI regarding its constituents and transport network'. A reference is made to '3 O-NSSI Feasibility Check Procedure'. A loop 'For each O-NSSI constituent' follows. Inside the loop, an alternative path 'Constituent is an O-NSSI constituent' leads to '4 Clause 6.2 O-NSSI Modification Procedure'. Another alternative path 'Constituent is an O-RAN Network Function' leads to an optional step 'Opt: if VNF needs to be instantiated/modified/deleted' (referencing '5 O-RAN.WG6.ORCH-USE-CASES Clause 3 Instantiate/Scale/Terminate NF On O-Cloud') and another optional step 'Opt: if O-RAN NF needs to be reconfigured' (referencing '6 O-RAN.WG1.01-Interface Clause 2.1 Provisioning Management Services'). After the loop, an optional step 'Opt: if O-NSSI constituent has TN part' leads to another loop 'For each transport network requirement'. Inside this loop, an alternative path 'Intra-Cloud' leads to '7 Request virtual link modification(s) within O-Cloud', and another alternative path 'Inter-Cloud' leads to '8 Request transport link modification(s) across O-Clouds'. After the loop, an optional step 'Opt: if O-NSSI MOI needs to be reconfigured' leads to '9 Configure O-NSSI MOI'. Another optional step 'Opt: if Non-RT RIC has subscribed for O-NSSI modification event notifications' leads to a reference '10 Notification of Non-RT RIC with updated O-NSSI information'. The process concludes with '11 Modify O-NSSI Response' from Slice Management Functions.](4f4518e51c251fad1672392b3f9dbc10_img.jpg) + +``` + +sequenceDiagram + participant SMF as Slice Management Functions + participant NFO + participant OAM as OAM Functions + participant TNM as TN Management Functions + participant NonRT as Non-RT RIC + + SMF->>SMF: 1 Modify O-NSSI Request + SMF->>SMF: 2 Derive the modification requirements for the O-NSSI regarding its constituents and transport network + SMF-->>SMF: ref + SMF-->>SMF: 3 O-NSSI Feasibility Check Procedure + + loop [For each O-NSSI constituent] + alt [Constituent is an O-NSSI constituent] + SMF-->>SMF: ref + SMF-->>SMF: 4 Clause 6.2 O-NSSI Modification Procedure + else [Constituent is an O-RAN Network Function] + alt Opt: if VNF needs to be instantiated/modified/deleted + SMF-->>SMF: ref + SMF-->>SMF: 5 O-RAN.WG6.ORCH-USE-CASES Clause 3 Instantiate/Scale/Terminate NF On O-Cloud + else Opt: if O-RAN NF needs to be reconfigured + SMF-->>SMF: ref + SMF-->>SMF: 6 O-RAN.WG1.01-Interface Clause 2.1 Provisioning Management Services + end + end + end + + alt Opt: if O-NSSI constituent has TN part + loop [For each transport network requirement] + alt [Intra-Cloud] + SMF->>OAM: 7 Request virtual link modification(s) within O-Cloud + else [Inter-Cloud] + SMF->>TNM: 8 Request transport link modification(s) across O-Clouds + end + end + alt Opt: if O-NSSI MOI needs to be reconfigured + SMF->>SMF: 9 Configure O-NSSI MOI + end + alt Opt: if Non-RT RIC has subscribed for O-NSSI modification event notifications + SMF-->>SMF: ref + SMF-->>NonRT: 10 Notification of Non-RT RIC with updated O-NSSI information + end + end + + SMF->>SMF: 11 Modify O-NSSI Response + +``` + +Sequence diagram for O-NSSI modification procedure. The diagram shows interactions between Slice Management Functions, NFO, OAM Functions, TN Management Functions, and Non-RT RIC. The process starts with a '1 Modify O-NSSI Request' from Slice Management Functions. It then proceeds to '2 Derive the modification requirements for the O-NSSI regarding its constituents and transport network'. A reference is made to '3 O-NSSI Feasibility Check Procedure'. A loop 'For each O-NSSI constituent' follows. Inside the loop, an alternative path 'Constituent is an O-NSSI constituent' leads to '4 Clause 6.2 O-NSSI Modification Procedure'. Another alternative path 'Constituent is an O-RAN Network Function' leads to an optional step 'Opt: if VNF needs to be instantiated/modified/deleted' (referencing '5 O-RAN.WG6.ORCH-USE-CASES Clause 3 Instantiate/Scale/Terminate NF On O-Cloud') and another optional step 'Opt: if O-RAN NF needs to be reconfigured' (referencing '6 O-RAN.WG1.01-Interface Clause 2.1 Provisioning Management Services'). After the loop, an optional step 'Opt: if O-NSSI constituent has TN part' leads to another loop 'For each transport network requirement'. Inside this loop, an alternative path 'Intra-Cloud' leads to '7 Request virtual link modification(s) within O-Cloud', and another alternative path 'Inter-Cloud' leads to '8 Request transport link modification(s) across O-Clouds'. After the loop, an optional step 'Opt: if O-NSSI MOI needs to be reconfigured' leads to '9 Configure O-NSSI MOI'. Another optional step 'Opt: if Non-RT RIC has subscribed for O-NSSI modification event notifications' leads to a reference '10 Notification of Non-RT RIC with updated O-NSSI information'. The process concludes with '11 Modify O-NSSI Response' from Slice Management Functions. + +**Figure 8.2-1: O-NSSI modification procedure** + +- 1) Modify request - Slice subnet management function receives a modify O-NSSI request (modifyMOIAttributes operation specified in 3GPP TS 28.532 [5], clause 11.1.1.3 shall apply). +- 2) Derive requirements - Based on the modification request, slice subnet management function derives modification requirements for the O-NSSI that may involve its constituents and transport network. + +- 3) Feasibility check - If required, slice subnet management function checks the feasibility of modification requirements utilizing O-NSSI feasibility check procedure. If the network slice subnet modification requirements can be satisfied, the following steps are needed, else go to step 11. + +For each O-NSSI constituent that needs modification, steps 4-9 are needed: + +- 4) Modification procedure - If the constituent is an O-NSSI constituent that needs to be modified, slice subnet management function invokes O-NSSI modification procedure (clause 8.2). + +If the constituent is an O-RAN network function, steps 5 and 6 are needed: + +- 5) NF orchestration - If the constituent network function is an O-RAN virtual network function that needs to be instantiated / modified / deleted, slice subnet management function realizes the following use cases as specified in O-RAN.WG6.ORCH-USE-CASES-v4.00 [18] depending on the modification requirements: + +- a. O-RAN.WG6.ORCH-USE-CASES-v4.00 [18], clause 3.2.1 Instantiate NF On O-Cloud +- b. O-RAN.WG6.ORCH-USE-CASES-v4.00 [18], clause 3.2.2 Scale Out of NF +- c. O-RAN.WG6.ORCH-USE-CASES-v4.00 [18], clause 3.2.3 Scale In of NF +- d. O-RAN.WG6.ORCH-USE-CASES-v4.00 [18], clause 3.2.5 Terminate NF on O-Cloud + +- 6) NF provisioning - If the constituent network function needs configuration changes, slice subnet management function executes provisioning management services as specified in O-RAN.WG1.O1-Interface.0-v4.00 [13], clause 2.1. + +If O-NSSI constituent has TN part that needs to be modified, for each transport network requirement, steps 7-8 are needed: + +- 7) Transport link request - If the transport link is within a cloud, slice subnet management function requests virtual link modification within respective O-Cloud from NFO. Details of this request are not defined in the present document. +- 8) Transport link modification - If the transport link is a physical link that is established across clouds, slice subnet management function requests transport link modification from TN management functions. Details of this request are not defined in the present document. +- 9) Reconfigure O-NSSI - If O-NSSI MOI needs to be modified, slice subnet management function reconfigures the O-NSSI MOI. + +- 10) Notification - If Non-RT RIC has subscribed for O-NSSI modification event notifications, slice subnet management function notifies Non-RT RIC with modified O-NSSI information. Details of event notification between slice subnet management function and Non-RT RIC are not defined in the present document. + +- 11) Modification response - Slice subnet management function returns O-NSSI modification result (modifyMOIAttributes operation specified in 3GPP TS 28.532 [5], clause 11.1.1.3 shall apply). + +## 8.3 O-RAN Slice Subnet Instance (O-NSSI) deallocation procedure + +The procedure for deallocation of an O-RAN slice subnet instance to satisfy the O-NSSI requirements is given in figure 8.3-1. + +![Sequence diagram for O-NSSI deallocation procedure. The diagram shows interactions between Slice Management Functions, NFO/FOCOM, OAM Functions, TN Management Functions, and Non-RT RIC. The process starts with a '1 Deallocate O-NSSI Request' from Slice Management Functions to NFO/FOCOM. An alternative block handles two cases: 'If O-NSSI needs to be modified' (referencing '2 Clause 6.2 O-NSSI Modification Procedure') and 'If O-NSSI needs to be terminated'. A loop 'For each O-NSSI constituent' contains an alternative block for 'Constituent is an O-NSSI constituent' (referencing '3 Clause 6.3 O-NSSI Deallocation Procedure') and 'Constituent is an O-RAN Network Function'. The latter has an alternative block for 'If O-RAN NF needs to be terminated and is a virtual NF' (steps 4 and 5) and 'If O-RAN NF needs to be modified' (steps 6 and 7). Another alternative block for 'If O-RAN NF needs to be reconfigured' contains step 8 and 9. After the loop, step 10 'Request modification/termination of transport link(s) across O-Clouds' is sent to TN Management Functions. An optional block 'If Non-RT RIC has subscribed for O-NSSI deallocation event notifications' contains step 11 'Notification of Non-RT RIC with O-NSSI deallocation'. The process ends with '12 Deallocate O-NSSI Response' from NFO/FOCOM to Slice Management Functions.](b6d267c207fc401bef94bdfe9035f5fd_img.jpg) + +**Service Management and Orchestration** + +``` + +sequenceDiagram + participant SMF as Slice Management Functions + participant NFO as NFO/FOCOM + participant OAM as OAM Functions + participant TNM as TN Management Functions + participant NonRT as Non-RT RIC + + SMF->>NFO: 1 Deallocate O-NSSI Request + alt [If O-NSSI needs to be modified] + ref [2 Clause 6.2 O-NSSI Modification Procedure] + else [If O-NSSI needs to be terminated] + loop [For each O-NSSI constituent] + alt [Constituent is an O-NSSI constituent] + ref [3 Clause 6.3 O-NSSI Deallocation Procedure] + else [Constituent is an O-RAN Network Function] + alt [If O-RAN NF needs to be terminated and is a virtual NF] + 4 Derive O-Cloud requirements for O-RAN NF termination + ref [5 Remove virtual intra-Cloud links, optionally deallocate slice tags (i.e. VLAN ID) and terminate NF on O-Cloud (O-RAN.WG6.ORCH-USE-CASES 3.10.2 Network Slice Deletion)] + else [If O-RAN NF needs to be modified] + opt [If O-RAN NF is a virtual NF that needs to be modified] + 6 Derive requirements for O-RAN NF modification request + ref [7 O-RAN.WG6.ORCH-USE-CASES 3.2.3 Scale In of NF] + end + opt [If O-RAN NF needs to be reconfigured] + 8 Derive CM requirements for O-RAN NF + ref [9 O-RAN.WG1.O1-Interface Clause 2.1 Provisioning Management Services] + end + end + end + end + 10 Request modification/termination of transport link(s) across O-Clouds + opt [If Non-RT RIC has subscribed for O-NSSI deallocation event notifications] + ref [11 Notification of Non-RT RIC with O-NSSI deallocation] + end + end + NFO->>SMF: 12 Deallocate O-NSSI Response + +``` + +Sequence diagram for O-NSSI deallocation procedure. The diagram shows interactions between Slice Management Functions, NFO/FOCOM, OAM Functions, TN Management Functions, and Non-RT RIC. The process starts with a '1 Deallocate O-NSSI Request' from Slice Management Functions to NFO/FOCOM. An alternative block handles two cases: 'If O-NSSI needs to be modified' (referencing '2 Clause 6.2 O-NSSI Modification Procedure') and 'If O-NSSI needs to be terminated'. A loop 'For each O-NSSI constituent' contains an alternative block for 'Constituent is an O-NSSI constituent' (referencing '3 Clause 6.3 O-NSSI Deallocation Procedure') and 'Constituent is an O-RAN Network Function'. The latter has an alternative block for 'If O-RAN NF needs to be terminated and is a virtual NF' (steps 4 and 5) and 'If O-RAN NF needs to be modified' (steps 6 and 7). Another alternative block for 'If O-RAN NF needs to be reconfigured' contains step 8 and 9. After the loop, step 10 'Request modification/termination of transport link(s) across O-Clouds' is sent to TN Management Functions. An optional block 'If Non-RT RIC has subscribed for O-NSSI deallocation event notifications' contains step 11 'Notification of Non-RT RIC with O-NSSI deallocation'. The process ends with '12 Deallocate O-NSSI Response' from NFO/FOCOM to Slice Management Functions. + +Figure 8.3-1: O-NSSI deallocation procedure + +- 1) Deallocation request - Slice subnet management function receives a deallocate O-NSSI request (DeallocateNssi operation specified in 3GPP TS 28.531 [4], clause 6.5.4 shall apply). + +Slice subnet management function decides whether the O-RAN slice subnet instance needs to be modified or terminated. If the O-NSSI needs to be modified, go to step 2 and then step 13, else steps 3-13 are needed. + +- 2) Modification procedure - Slice subnet management function invokes the O-NSSI modification procedure. + +For each O-NSSI constituent, steps 3-9 are needed: + +- 3) Deallocation procedure - If the constituent is an O-NSSI constituent, slice subnet management function invokes O-NSSI deallocation procedure (clause 8.3). Then go to step 13. + +If the constituent is an O-RAN NF, steps 4-9 are needed: + +If O-RAN NF needs to be terminated and is a virtual NF, steps 4-5 are needed, else if O-RAN NF needs to be modified go to step 6. + +- 4) Derive requirements - Slice subnet management function derives the O-Cloud requirements for O-RAN NF termination to terminate the NF within the respective O-Cloud. + +- 5) Terminate NF - Slice subnet management function removes virtual intra-Cloud links, optionally deallocates slice tags (i.e., VLAN ID) and terminates NF on O-Cloud utilizing steps as specified in network slice deletion use case in O-RAN.WG6.ORCH-USE-CASES-v4.00 [18], clause 3.10.2. + +If O-RAN NF is a virtual NF that needs to be modified, steps 6-7 are needed, else go to step 8: + +- 6) Derive requirements - Slice subnet management function derives the requirements for O-RAN NF modification request to modify the NF within the respective O-Cloud. + +- 7) Scale NF - Slice subnet management function invokes Scale In of NF use case as specified in O-RAN.WG6.ORCH-USE-CASES-v4.00 [18], clause 3.2.3. + +If O-RAN NF needs to be reconfigured, steps 8-9 are needed, else go to step 10: + +- 8) CM requirements - Slice subnet management function derives the CM requirements for the O-RAN NF. + +- 9) NF provisioning - Slice subnet management function invokes provisioning management services as specified in O-RAN.WG1.O1-Interface.0-v4.00 [13], clause 2.1. + +For each transport network requirement, step 10 is needed: + +- 10) Transport link request - If the transport link is a physical link that needs to be modified/terminated across clouds, slice subnet management function request transport link modification/termination from TN management functions. + +- 11) Notification - If Non-RT RIC has subscribed for O-NSSI deallocation event notifications, slice subnet management function notifies Non-RT RIC with O-NSSI deallocation. + +- 12) Deallocation response - Slice subnet management function returns appropriate O-NSSI deallocation result (DeallocateNssi operation specified in 3GPP TS 28.531 [4], clause 6.5.4 shall apply). + +## 8.4 O-RAN Slice Subnet Instance (O-NSSI) feasibility check and reservation procedure + +### 8.4.1 Introduction + +The feasibility check and reservation procedure enables a service consumer to perform feasibility check and request reservation for O-NSSIs. The reservation request is optional. The procedure determines if adequate resources are available to support the O-RAN network slice subnet related requirements provided in the request. The procedure also allows a service consumer to request the reservation of those resources for specified time window. + +### 8.4.2 Procedure + +The procedure for feasibility check and reservation of an O-RAN slice subnet instance is given in figure 8.4.2-1. + +![Sequence diagram for O-NSSI feasibility check and reservation procedure. The diagram is divided into two main sections: 'Job Creation' and 'Job Progress'. The 'Job Creation' section shows the SMO Service Consumer sending a request (1) to Slice Management Functions, which then creates and configures a job instance (2) and starts the feasibility check process. The SMO Service Consumer receives a response (3). The 'Job Progress' section is enclosed in a 'par' block. It contains a 'loop' for each O-NSSI constituent where the feasibility check process (4) is executed, and if resource reservation is true, the reservation process (5) is also executed. After the loop, progress is notified (6). A final conclusion (7) is sent. An optional section shows a progress query request (8) from the consumer, which is read (9) and responded to (10). Another optional section shows a job deletion request (11) from the consumer, which triggers a loop to cancel reservations (12) and delete the job (13), followed by a deletion response (14).](4994db156275fd23db6efc171a058c31_img.jpg) + +``` + +sequenceDiagram + participant SMO as SMO Service Consumer + participant SMF as Slice Management Functions + participant FOCOM + participant OAM as OAM Functions + participant TNM as TN Management Functions + participant NonRT as Non-RT RIC + + Note over SMF: Job Creation + SMO->>SMF: 1 O-NSSI Feasibility Check and Reservation Job Creation request + SMF->>SMF: 2 Create and configure feasibility check and reservation job instance and start feasibility check process + SMF-->>SMO: 3 O-NSSI Feasibility Check and Reservation Job Creation response + + Note over SMF: Job Progress + par + loop [(For each O-NSSI constituent) && (job is active)] + ref + SMF->>SMF: 4 Feasibility check process + and + Opt: If resource reservation is true + ref + SMF->>SMF: 5 Reservation process + end + end + and + Opt: If resource reservation is true + SMF->>SMO: 6 Notify progress + end + end + SMF->>SMO: 7 Final Feasibility and Reservation conclusion + + Opt: If consumer wants to know the progress + SMO->>SMF: 8 Feasibility Check and Reservation progress query request + SMF->>SMF: 9 Read corresponding information of feasibility check and reservation job instance + SMF-->>SMO: 10 Feasibility Check and Reservation progress query response + end + + Opt: If consumer is no longer cares about feasibility + SMO->>SMF: 11 Feasibility Check and Reservation Job deletion request + loop [(For each reserved O-NSSI constituent)] + Opt: If resource reservation is true + ref + SMF->>SMF: 12 Reservation cancellation process + end + end + SMF->>SMF: 13 Delete job + SMF-->>SMO: 14 Feasibility Check and Reservation Job deletion response + end + end + +``` + +Sequence diagram for O-NSSI feasibility check and reservation procedure. The diagram is divided into two main sections: 'Job Creation' and 'Job Progress'. The 'Job Creation' section shows the SMO Service Consumer sending a request (1) to Slice Management Functions, which then creates and configures a job instance (2) and starts the feasibility check process. The SMO Service Consumer receives a response (3). The 'Job Progress' section is enclosed in a 'par' block. It contains a 'loop' for each O-NSSI constituent where the feasibility check process (4) is executed, and if resource reservation is true, the reservation process (5) is also executed. After the loop, progress is notified (6). A final conclusion (7) is sent. An optional section shows a progress query request (8) from the consumer, which is read (9) and responded to (10). Another optional section shows a job deletion request (11) from the consumer, which triggers a loop to cancel reservations (12) and delete the job (13), followed by a deletion response (14). + +**Figure 8.4.2-1: O-NSSI feasibility check and reservation procedure** + +- 1) Feasibility check and reservation job creation request – Slice management function receives a O-NSSI feasibility check and reservation job creation request from the SMO service consumer. +- 2) Instance creation – The slice management function creates and configures the `FeasibilityCheckAndReservationJob` instance and applies the attributes received from the request. See 3GPP TS 28.541 [7], clause 6.3.37 for more details on the IOC. Then, the slice management function starts executing the feasibility check process. +- 3) Feasibility check and reservation job creation response – The slice management function sends the O-NSSI feasibility check and reservation job creation response for the received Distinguished Name (DN) of the + +FeasibilityCheckAndReservationJob instance back to the SMO service consumer. See Create Managed Object Instance operation described in O-RAN WG1 O1-Interface [13], clause 2.1. + +- 4) Feasibility check – For each O-NSSI constituent that has an active job, the slice management function performs a feasibility check within the SMO internally, such as communicating with FOCOM, OAM functions and TN management functions, as to whether the resources are available. This would be a use case from the Cloudification & Orchestration (WG6) in the O-RAN WG6.ORCH-USE-CASES [18] specification using the NFO and FOCOM SMOS services. +- 5) Reservation procedure – Slice management function performs resource reservation process when resourceReservation is true and feasibility result is feasible. The reservation procedure for the constituent network slice subnet is a use case from the Cloudification & Orchestration (WG6) use cases with the NFO and FOCOM SMOS services. +- 6) Progress notification – The SMO service consumer may subscribe for the attribute value change notifications for this specific job or for any of the job(s) created by it to receive any asynchronous job progress notifications for those job(s). The slice management function sends an asynchronous job progress notification for the feasibility check and reservation process with processMonitor attributes to the SMO service consumer. +- 7) Reservation conclusion – The slice management function sends the final notification with the feasibility check and reservation status. This includes the feasibilityResult, inFeasibleReason, resourceReservation status, reservationFailure reason, reservation expiration and recommended requirements of the feasibility check and reservation job. + +A progress check is performed in steps 8-10: + +- 8) The SMO service consumer can send a feasibility check and reservation progress query request to slice management function any time, to query about the feasibility check and reservation job status and receive the feasibility check and reservation job status. +- 9) The slice management function reads the corresponding information of the feasibility check and reservation job instance. +- 10) The slice management function returns the feasibility check and reservation progress query response. + +SMO service consumer deletes the feasibility and reservation job in steps 11-14: + +- 11) Delete operation – SMO service consumer can request to delete the feasibility check and reservation job any time. This is done by sending to the slice management function a feasibility check and reservation job deletion request. +- 12) For each reserved O-NSSI constituent, the cancel the reservation process is executed. +- 13) The slice management function deletes the job. +- 14) The slice management function returns a feasibility check and reservation job deletion response back to the slice management function. + +# Annex A (informative): Implementation options + +## A.1 Implementation options + +This clause presents example deployment options for various SMO options. + +### A.1.1 3GPP and ETSI NFV-MANO based O-RAN slicing architecture implementation option + +![Figure A.1.1-1: O-RAN slicing reference architecture (ETSI NFV-MANO based example). The diagram shows a multi-layered architecture. At the top, NSMF, RAN NSSMF, and NFMF are connected to SMO Functions (NFVO, VNFM) via Os-Ma-Nfvo and Ve-Vnm-Em interfaces. A Non-RT RIC is also shown. The SMO Layer is separated by a dashed line. Below it, the Near-RT RIC is connected to O-CU-CP and O-CU-UP via E2 interfaces. O-CU-CP and O-CU-UP are connected to O-DU via F1-C and F1-U interfaces. O-DU is connected to O-RU via the Open Fronthaul M-Plane. The O-RU is connected to O-Cloud. The architecture is divided into two sections by a dashed line labeled O1 and O2.](86b46dc467751bd111b3727806cd7f44_img.jpg) + +Figure A.1.1-1: O-RAN slicing reference architecture (ETSI NFV-MANO based example). The diagram shows a multi-layered architecture. At the top, NSMF, RAN NSSMF, and NFMF are connected to SMO Functions (NFVO, VNFM) via Os-Ma-Nfvo and Ve-Vnm-Em interfaces. A Non-RT RIC is also shown. The SMO Layer is separated by a dashed line. Below it, the Near-RT RIC is connected to O-CU-CP and O-CU-UP via E2 interfaces. O-CU-CP and O-CU-UP are connected to O-DU via F1-C and F1-U interfaces. O-DU is connected to O-RU via the Open Fronthaul M-Plane. The O-RU is connected to O-Cloud. The architecture is divided into two sections by a dashed line labeled O1 and O2. + +**Figure A.1.1-1: O-RAN slicing reference architecture (ETSI NFV-MANO based example)** + +A 3GPP – ETSI NFV-MANO based example of O-RAN slicing reference architecture and interfaces is shown in figure A.1.1-1 to describe the relationship between 3GPP defined slice management functions (NSMF, NSSMF), 3GPP defined management functions (3GPP TS 28.531 [4], Network Function Management Function (NFMF) and O-RAN network functions in terms of slice lifecycle management and slice configuration procedures. Life Cycle Management (LCM) procedures for mobile networks that include Virtualized Network Functions (VNFs) as well as addition of Physical Network Functions (PNFs) to Network Service (NS) instances are specified in 3GPP TS 28.526 [3]. + +### A.1.2 ONAP based O-RAN slicing architecture implementation option + +![Figure A.1.2-1: Example architecture depiction for ONAP based O-RAN slicing support. The diagram shows a multi-layered architecture. At the top, the U-UI layer includes CSMF Portal and NSMF Portal. Below this is the EXT-API layer with Service LCM APIs. The SMO Layer contains several components: SO (CSMF, NSMF, RAN NSSMF), Policy (A&AI, Service Profile, NSI, Slice Profile, NSSI), OOF, SDC (CST, NST, NSSI, Service Profile, Slice Profile Templates), CCSDK/SDN-C (RAN & Transport specific config), CDS, DCAE, and Non-RT RIC. The SMO Layer is connected to the Near-RT RIC via interfaces O1, A1, and O2. The Near-RT RIC is connected to O-CU-CP and O-CU-UP via E2 interfaces. O-CU-CP and O-CU-UP are connected to O-DU via F1-C and F1-U interfaces. O-DU is connected to O-RU via the Open Fronthaul M-Plane. O-RU is connected to O-Cloud. The Open Fronthaul M-Plane is highlighted in red.](42b5b51c58263d4f684e4de5cf2c1c5e_img.jpg) + +Figure A.1.2-1: Example architecture depiction for ONAP based O-RAN slicing support. The diagram shows a multi-layered architecture. At the top, the U-UI layer includes CSMF Portal and NSMF Portal. Below this is the EXT-API layer with Service LCM APIs. The SMO Layer contains several components: SO (CSMF, NSMF, RAN NSSMF), Policy (A&AI, Service Profile, NSI, Slice Profile, NSSI), OOF, SDC (CST, NST, NSSI, Service Profile, Slice Profile Templates), CCSDK/SDN-C (RAN & Transport specific config), CDS, DCAE, and Non-RT RIC. The SMO Layer is connected to the Near-RT RIC via interfaces O1, A1, and O2. The Near-RT RIC is connected to O-CU-CP and O-CU-UP via E2 interfaces. O-CU-CP and O-CU-UP are connected to O-DU via F1-C and F1-U interfaces. O-DU is connected to O-RU via the Open Fronthaul M-Plane. O-RU is connected to O-Cloud. The Open Fronthaul M-Plane is highlighted in red. + +**Figure A.1.2-1: Example architecture depiction for ONAP based O-RAN slicing support** + +Current version of ONAP - O-RAN slicing reference architecture is shown in figure A.1.2-1 (based on ONAP G-release). In this architecture, one option is RAN NSSMF being located within SMO and is responsible for the entire RAN subnet, including the O-RAN NFs and the related O-RAN transport network components; Fronthaul interface (FH) between O-RU and O-DU and Midhaul interface (MH) between O-DU and O-CU. RAN NSSMF determines slice specific configuration of O-RAN NFs based on SliceProfile received from NSMF and determines the necessary slice specific requirements for FH and MH interface triggering Transport Network Management Domain (TN MD) to execute the actual configuration of FH and MH interface. ETSI ZSM based management domain approach is adopted for TN management. + +# Annex B (informative): Transport network slicing + +## B.1 Transport network slicing use cases + +This clause describes the ORAN transport network slicing related use cases and per-slice configuration of O-RAN transport network instances, phases of transport network slicing definition process and the corresponding scope of work for the relevant O-RAN WGs, considering the projected progress. + +Transport network slicing use cases are built based on the definitions of slicing in O-RAN WG1 Slicing Architecture Specification, WG6.CAD Scenario C.1 and C.2, WG4 O-RU Slicing with support of RAN-Sharing (WG4 Use Case 7 and Use Case 10). + +Transport network slicing use cases are grouped into phases to incrementally extend the scope of work in relevant O-RAN WGs. + +Brief definition of phases: + +Phase 1: Slicing as specified in 3GPP TS 22.261 [1], [i.2] and 3GPP TS 23.501 [2]. Slicing appears on the N3 (NG) interface. Number of slices are limited. UPF is centrally located. + +Phase 2: Phase 1 is augmented with per-slice QoS characteristics. Slices are multiple with multiple exit-points and local break-outs. + +Phase 3 and beyond are not defined in the present document. + +For the current version of transport network slicing use cases the following scope and constraints are assumed, based on mutual discussions and agreements between WG1, WG6, WG9: + +- Delineation of slices in O-RAN CUPS user plane interfaces for current phases 1-5 is based on physical or VLAN+IP separation. For this delineation, procedures for coordination between TNrd parties. From phase 3 and beyond, midhaul is slicing aware domain, serving communication of O-CU-UP CU\_UP F1\_U 5QIDSCP) leading to 'CU-UP SST1 MBB' (VPN Slice 1, UPF(s)1), 'Vlan+IP Slice 2' (5QI->DSCP) leading to 'CU-UP SST2 MTC' (VPN Slice 2, UPF(s)2), and 'Vlan+IP Slice 3' (5QI->DSCP) leading to 'CU-UP S-NSSAI Private Network' (VPN Slice 3, UPF(s)3). The right part shows a cluster of O-DU blocks (Cluster N, Cluster M, Cluster K) connected to three CU-UP blocks (CU-UP SST1 MBB, CU-UP SST2 MTC, CU-UP S-NSSAI Private Network) in a mesh topology.](ec8e910924591f6c85a77de7fd673aaf_img.jpg) + +Figure B.1-1: Assumption of mapping functions of O-DU and O-CU-UP to slices. The diagram is divided into two parts. The left part, titled 'CU\_UP slicing: slice mapped and operated by cluster of CU\_UPs', shows three O-RU blocks connected to an O-DU block. The O-DU block is connected to three separate paths: 'Vlan+IP Slice 1' (5QI->DSCP) leading to 'CU-UP SST1 MBB' (VPN Slice 1, UPF(s)1), 'Vlan+IP Slice 2' (5QI->DSCP) leading to 'CU-UP SST2 MTC' (VPN Slice 2, UPF(s)2), and 'Vlan+IP Slice 3' (5QI->DSCP) leading to 'CU-UP S-NSSAI Private Network' (VPN Slice 3, UPF(s)3). The right part shows a cluster of O-DU blocks (Cluster N, Cluster M, Cluster K) connected to three CU-UP blocks (CU-UP SST1 MBB, CU-UP SST2 MTC, CU-UP S-NSSAI Private Network) in a mesh topology. + +**Figure B.1-1: Assumption of mapping functions of O-DU and O-CU-UP to slices** + +From O-RAN perspective, a single network slice may start from O-DU and may have multiple distributed O-CU-UPs and UPFs, connecting a certain slice in data network with multiple N6 interfaces and multiple local breakouts. + +In TN domain TNEs with attachment circuits to O-RU, O-DU and O-CU-CP and O-CU-UP maintain corresponding QoS schemes and transport network slice profiles as shown in figure B.1-2 and in figure B.1-3. + +![Figure B.1-2: Types of slicing in various O-RAN scenarios. This diagram shows four scenarios from top to bottom: 1. 'Bundled option: Micro/Small, OMAC' shows O-RU connected to O-DU, which is connected to CU-UP, which is connected to UPF(s). Slicing is 'O-NSSI based slicing' at the O-DU/UPF(s) interface. 2. 'Small to Mid: Integrated Architecture' shows O-RU connected to O-DU, which is connected to CU-UP, which is connected to UPF(s). Slicing is 'O-NSSI based slicing' at both the O-DU/UPF(s) and CU-UP/UPF(s) interfaces. 3. 'Med/Macro: Edge Cloud Architecture' shows O-RU connected to O-DU, which is connected to CU-UP, which is connected to UPF(s). Slicing is 'PLMN ID based slicing' at the O-RU/O-DU interface and 'O-NSSI based slicing' at the O-DU/UPF(s) interface. 4. 'Macro: Targeted ORAN Architecture' shows O-RU connected to O-DU, which is connected to CU-UP, which is connected to UPF(s). Slicing is 'PLMN ID based slicing' at the O-RU/O-DU interface, and 'O-NSSI based slicing' at both the O-DU/UPF(s) and CU-UP/UPF(s) interfaces. All scenarios show 'VLAN+IP' and '5QI->DSCP slicing' between O-DU and CU-UP.](f194427ba7fc38d53a3cf6999ff49d96_img.jpg) + +Figure B.1-2: Types of slicing in various O-RAN scenarios. This diagram shows four scenarios from top to bottom: 1. 'Bundled option: Micro/Small, OMAC' shows O-RU connected to O-DU, which is connected to CU-UP, which is connected to UPF(s). Slicing is 'O-NSSI based slicing' at the O-DU/UPF(s) interface. 2. 'Small to Mid: Integrated Architecture' shows O-RU connected to O-DU, which is connected to CU-UP, which is connected to UPF(s). Slicing is 'O-NSSI based slicing' at both the O-DU/UPF(s) and CU-UP/UPF(s) interfaces. 3. 'Med/Macro: Edge Cloud Architecture' shows O-RU connected to O-DU, which is connected to CU-UP, which is connected to UPF(s). Slicing is 'PLMN ID based slicing' at the O-RU/O-DU interface and 'O-NSSI based slicing' at the O-DU/UPF(s) interface. 4. 'Macro: Targeted ORAN Architecture' shows O-RU connected to O-DU, which is connected to CU-UP, which is connected to UPF(s). Slicing is 'PLMN ID based slicing' at the O-RU/O-DU interface, and 'O-NSSI based slicing' at both the O-DU/UPF(s) and CU-UP/UPF(s) interfaces. All scenarios show 'VLAN+IP' and '5QI->DSCP slicing' between O-DU and CU-UP. + +**Figure B.1-2: Types of slicing in various O-RAN scenarios** + +![Figure B.1.-3: Types of attachment circuits in TNE. This diagram illustrates the network architecture across three site types: (R)AN cell site, Hub site, and Metro POP site. It shows three service models: FH service model (Band Sub-6), 5QI service model (High Band), and QCI service model (Legacy). The FH service model uses eCPRI for Fronthaul and eCPRI (7.2x) for Midhaul/Backhaul. The 5QI service model uses eCPRI for Midhaul and F1 for Backhaul. The QCI service model uses CPRI for Backhaul and S1, X2, Xx for Midhaul/Backhaul. The diagram also shows various network elements like O-RU, RRH, FGH, O-DU, MEC, O-CU, and connections to 5GC, CDN, and EPC.](a11d6ea495980d5cd31e6330976825a2_img.jpg) + +Figure B.1.-3: Types of attachment circuits in TNE. This diagram illustrates the network architecture across three site types: (R)AN cell site, Hub site, and Metro POP site. It shows three service models: FH service model (Band Sub-6), 5QI service model (High Band), and QCI service model (Legacy). The FH service model uses eCPRI for Fronthaul and eCPRI (7.2x) for Midhaul/Backhaul. The 5QI service model uses eCPRI for Midhaul and F1 for Backhaul. The QCI service model uses CPRI for Backhaul and S1, X2, Xx for Midhaul/Backhaul. The diagram also shows various network elements like O-RU, RRH, FGH, O-DU, MEC, O-CU, and connections to 5GC, CDN, and EPC. + +Figure B.1.-3: Types of attachment circuits in TNE + +The assumptions of slicing capabilities on the core and O-RAN for the option 1 which are mapped to the phase 1 are given in figure B.1-4. + +The option 2 depicts the expectation of the target capabilities of the systems, including capabilities on the option 1. + +![Figure B.1-4: Options for slicing, demapping orthogonal plane of 5QI per slice in option 1 and multiple planes of 5QI as attribute per planes of slices. This diagram compares Option 1 and Option 2 for slicing. Option 1 shows a single 5QI slice mapped to a DSCP in the ORAN element and DSCP Queues MPLS-exp in the TNE. Option 2 shows a set of 5QI per slice (S-NSSAI #) mapped to a DSCP (interface) in the ORAN element and DSCP Queues MPLS-exp Soft Slice Hard Slice in the TNE. Option 1 also shows S-NSSAI mapped to VLAN + IP in the ORAN element and VLAN + (optional IP) L2VPN (VPLS) EVPN L3VPN (VRF) in the TNE. Option 2 shows a slice (S-NSSAI) mapped to VLAN + IP (interface) in the ORAN element and VLAN + (optional IP) L2VPN (VPLS) EVPN L3VPN (VRF) in the TNE.](9a7b18ee4c6a7b535e13586fa556b873_img.jpg) + +Figure B.1-4: Options for slicing, demapping orthogonal plane of 5QI per slice in option 1 and multiple planes of 5QI as attribute per planes of slices. This diagram compares Option 1 and Option 2 for slicing. Option 1 shows a single 5QI slice mapped to a DSCP in the ORAN element and DSCP Queues MPLS-exp in the TNE. Option 2 shows a set of 5QI per slice (S-NSSAI #) mapped to a DSCP (interface) in the ORAN element and DSCP Queues MPLS-exp Soft Slice Hard Slice in the TNE. Option 1 also shows S-NSSAI mapped to VLAN + IP in the ORAN element and VLAN + (optional IP) L2VPN (VPLS) EVPN L3VPN (VRF) in the TNE. Option 2 shows a slice (S-NSSAI) mapped to VLAN + IP (interface) in the ORAN element and VLAN + (optional IP) L2VPN (VPLS) EVPN L3VPN (VRF) in the TNE. + +Figure B.1-4: Options for slicing, demapping orthogonal plane of 5QI per slice in option 1 and multiple planes of 5QI as attribute per planes of slices + +For phase 1 following constrains are assumed (see figure B.1.5): + +- 1) Single operator with one O-NSSI MBB, one O-NSSI mMTC, one O-NSSI NB-IoT slice. +- 2) Fix mapping of slices inter to intra – DC. +- 3) Flat mapping of standards based 5QI (3GPP TS 23.501 [2], table 5.7.4-1) $\leftrightarrow$ DSCP $\leftrightarrow$ QoS in TN domain. + +![Figure B.1-5: Diagram of network location of O-RAN instances with relevant domains for use cases. The diagram shows a 6x4 grid of network elements across different domains (Core DC Central POP, Regional Zone Big POP, Collector Rural Mid POP, RAN Cluster POP, RAN BBU POP, RAN RU POP) and slices (Latency, MBB slice, mMTC slice, NB-IoT slice). It details the placement of UPF, Sec-GW, O-CU-UP, O-DU, BBU, O-RU, and Distributed/Collocated components, along with latency and distance requirements.](d44cc0f93247df950549918efda53e70_img.jpg) + +Figure B.1-5 illustrates the network location of O-RAN instances across different domains and slices. The domains are categorized by latency and distance requirements, while the slices are categorized by their specific network elements and deployment options. + +| Domain | Latency | MBB slice | mMTC slice | NB-IoT slice | +|-------------------------|-----------------|-------------------------------------------|-------------------------------------------|-------------------------------------------| +| Core DC Central POP | <500km
<30ms | UPF
Sec-GW | UPF
Sec-GW | UPF
Sec-GW | +| Regional Zone Big POP | <150km
<15ms | IPSEC | IPSEC | IPSEC | +| Collector Rural Mid POP | <60km
<5ms | O-CU-UP | O-CU-UP | O-CU-UP | +| RAN Cluster POP | <30km
<2ms | Split 2
IPSEC* | Split 2
IPSEC* | Split 2
IPSEC* | +| RAN BBU POP | <20km
<1ms | O-DU, BBU | O-DU, BBU | O-DU, BBU | +| RAN RU POP | | Split 7.2k
O-DU
O-RU
Distributed | Split 7.2k
O-DU
O-RU
Distributed | Split 7.2k
O-DU
O-RU
Distributed | + +\*optional, IPSEC is mandatory for F1-C (not shown) + +Figure B.1-5: Diagram of network location of O-RAN instances with relevant domains for use cases. The diagram shows a 6x4 grid of network elements across different domains (Core DC Central POP, Regional Zone Big POP, Collector Rural Mid POP, RAN Cluster POP, RAN BBU POP, RAN RU POP) and slices (Latency, MBB slice, mMTC slice, NB-IoT slice). It details the placement of UPF, Sec-GW, O-CU-UP, O-DU, BBU, O-RU, and Distributed/Collocated components, along with latency and distance requirements. + +Figure B.1-5: Diagram of network location of O-RAN instances with relevant domains for use cases + +As an outcome of the following mapping, it is expected capability of TN domain to accommodate all domains with relevant QoS profiles and slices in each TNE, as shown in figure B.1.6 below: + +![Figure B.1-6: Diagram of O-RAN flows to be accommodated in each TNE. The diagram shows the flow of O-RAN elements (O-RU, O-DU, CU-UP, UPF(s)) across different TNEs (Far edge QoS Scope, Core QoS Scope) and their corresponding QoS characteristics (Scope of the standardized 5Q characteristics, Scope of the partially* standardized 5Q characteristics, Scope of the standardized Fronthaul characteristics, Scope of SLA characteristics).](8c08df601faa873f2eefa0a356daff5d_img.jpg) + +Figure B.1-6 illustrates the O-RAN flows to be accommodated in each TNE. The diagram shows the flow of O-RAN elements (O-RU, O-DU, CU-UP, UPF(s)) across different TNEs (Far edge QoS Scope, Core QoS Scope) and their corresponding QoS characteristics (Scope of the standardized 5Q characteristics, Scope of the partially\* standardized 5Q characteristics, Scope of the standardized Fronthaul characteristics, Scope of SLA characteristics). + +Figure B.1-6: Diagram of O-RAN flows to be accommodated in each TNE. The diagram shows the flow of O-RAN elements (O-RU, O-DU, CU-UP, UPF(s)) across different TNEs (Far edge QoS Scope, Core QoS Scope) and their corresponding QoS characteristics (Scope of the standardized 5Q characteristics, Scope of the partially\* standardized 5Q characteristics, Scope of the standardized Fronthaul characteristics, Scope of SLA characteristics). + +Figure B.1-6: Diagram of O-RAN flows to be accommodated in each TNE + +Table B.1-1 captures assumptions of TN slicing capabilities in each interface for the phase 1. + +Table B.1-1: Scope of the capabilities of O-RAN elements in phase 1 + +| ORAN interface | Stream direction | Queue | Slicing VLAN | Differentiated QoS behavior per slice | +|-------------------|------------------|---------|--------------|---------------------------------------| +| Fronthaul C/U | Any | EF (HP) | No | No | +| Fronthaul M-pane, | Any | AF | No | No | + +| ORAN interface | Stream direction | Queue | Slicing VLAN | Differentiated QoS behavior per slice | +|------------------------------------|------------------|----------------------------------------|--------------|---------------------------------------| +| E1, E2, F1_c, O2, A1, Xn_c, N2, N4 | | | | | +| F1_U | DU > CU-UP | AF* or 5QI<>DSCP mapped** | No | No | +| F1_U | CU-UP > DU | 5QI<>DSCP mapped** | No | No | +| N3 (NG) | CU-UP > UPF | 5QI<>DSCP mapped** | Yes | No | +| N3 | UPF > CU-UP | 5QI<>DSCP mapped** | Yes | No | +| Xn_U | Any | 5QI<>DSCP mapped
(as per TS 38.424) | No | No | + +\* Based on current 3GPP TS38.474, clause 5.4 definition of 5QI<>DSCP capability of F1\_U for the link DU > CU-UP may be limited. If this is the case, for the phase 1 the mapping of F1\_U is recommended to a bandwidth queue. + +\*\* 5QI QoS identifiers, the priority level (if explicitly signaled), and other NG-RAN traffic parameters (e.g., ARP) in O-RAN and core domains mapped to DSCP and ToS or CoS parameters, aligned with TN domain with accordance to NRM as specified in 3GPP TS 28.541 [7], with the flow shown in figure B.1-7 below: + +![Diagram of profiles information model parameters mapped to the domains to form a slice. The diagram shows the mapping from GSMA NG.116 (Requirements, GST, NEST) and TS 28.541 (6.3.23 RANsliceSubnetProfile, 6.3.24 TopSliceSubnetProfile, 6.3.22 CNSliceSubnetProfile) to the TN domain (CU-UP 1, 2, ..., N, S-NSSAI MTC) and UPF. The TN domain is connected to the UPF via TNE interfaces.](6f8a4e16275a66786a5ead8ea755fabb_img.jpg) + +The diagram illustrates the mapping of profile information model parameters from GSMA NG.116 and TS 28.541 to the domains to form a slice. It shows the flow from Requirements (GST, NEST) and RANsliceSubnetProfile (4.3.11 EP\_NgU, 6.3.17 EP\_Transport) to the TN domain (CU-UP 1, 2, ..., N, S-NSSAI MTC) and UPF. The TN domain is connected to the UPF via TNE interfaces. + +Diagram of profiles information model parameters mapped to the domains to form a slice. The diagram shows the mapping from GSMA NG.116 (Requirements, GST, NEST) and TS 28.541 (6.3.23 RANsliceSubnetProfile, 6.3.24 TopSliceSubnetProfile, 6.3.22 CNSliceSubnetProfile) to the TN domain (CU-UP 1, 2, ..., N, S-NSSAI MTC) and UPF. The TN domain is connected to the UPF via TNE interfaces. + +**Figure B.1-7: Diagram of profiles information model parameters mapped to the domains to form a slice** + +According to these parameters, the relation of RANsliceSubnetProfile and RANsliceSubnetProfile with VLAN and IP mapping could be established with corresponding EP\_Transport VLAN and IP mapping, allowing TN domain to perform separation allocation of resources per slice. + +Definition of 3GPP IM/DM in 3GPP TS 28.541 [7] TN domain is out of scope, and network slice parameters of the RAN and CN are existing in the corresponding fields of the IM/DM. More details in of 3GPP IM/DM in regard for network slicing can be found in O-RAN.WG9.XTRP-MGT.0-v04.00 [i.19], clause 9.1. + +**Phase 2 assumes the following constrains** (see figure B.1-8): + +- 1) Single operator with enterprise slices use case. +- 2) Number of slices: many. +- 3) Multiple exit points and multiple UPFs. +- 4) Per-slice (tenant) 5QI<>DSCP<>QoS model in TN domain. + +![Figure B.1-8: Scope of the capabilities of O-RAN elements in phase 2. This diagram illustrates the network architecture for four slices: Latency, MBB IPTV slice, Enterprise Core slice, and Enterprise PC slice. The architecture is organized into six horizontal layers representing different network components: Core DC Central POP, Regional Zone Big POP, Collector Rural Mid POP, RAN Cluster POP, RAN BBU POP, and RAN RU POP. The Latency slice shows a direct path from Core DC to RAN RU with latency targets (<500km, <30ms). The MBB IPTV slice uses a CDN, Application-driven architecture with a [Secondary] Sec-GW, UPF. The Enterprise Core slice features a Core breakout to Enterprise/public cloud with a Sec-GW, UPF. The Enterprise PC slice includes a Core breakout, Sec-GW1, UPF1, and a Local breakout. The RAN BBU POP layer shows O-DU, BBU and O-DU, BBU components. The RAN RU POP layer shows O-DU and O-RU components. The diagram also indicates the use of IPSEC and Split 2 for traffic separation. A footnote at the bottom right states: '*optional, IPSEC is mandatory for F1-C (not shown)'.](9090275a31042335e5d90b4abf001886_img.jpg) + +Figure B.1-8: Scope of the capabilities of O-RAN elements in phase 2. This diagram illustrates the network architecture for four slices: Latency, MBB IPTV slice, Enterprise Core slice, and Enterprise PC slice. The architecture is organized into six horizontal layers representing different network components: Core DC Central POP, Regional Zone Big POP, Collector Rural Mid POP, RAN Cluster POP, RAN BBU POP, and RAN RU POP. The Latency slice shows a direct path from Core DC to RAN RU with latency targets (<500km, <30ms). The MBB IPTV slice uses a CDN, Application-driven architecture with a [Secondary] Sec-GW, UPF. The Enterprise Core slice features a Core breakout to Enterprise/public cloud with a Sec-GW, UPF. The Enterprise PC slice includes a Core breakout, Sec-GW1, UPF1, and a Local breakout. The RAN BBU POP layer shows O-DU, BBU and O-DU, BBU components. The RAN RU POP layer shows O-DU and O-RU components. The diagram also indicates the use of IPSEC and Split 2 for traffic separation. A footnote at the bottom right states: '\*optional, IPSEC is mandatory for F1-C (not shown)'. + +**Figure B.1-8: Scope of the capabilities of O-RAN elements in phase 2** + +\* 5QI QoS identifiers, the priority level (if explicitly signaled), and other NG-RAN traffic parameters (e.g., ARP) in O-RAN and core domains mapped to DSCP and ToS or CoS parameters, aligned with TN domain with accordance to NRM as specified in 3GPP TS 28.541 [7], with the flow shown in figure B.1-9 below: + +### Phase 2 and 3: + +![Figure B.1-9: Diagram of use cases for phase 2 and 3. The diagram shows a network architecture for Cloud Deployment Scenarios C, C.1, and C.2. It includes a 'Latency' column with distance and delay targets for different network layers: Core DC Central POP (<500km, <30ms), Regional Zone Big POP (<150km, <15ms), Collector Rural Mid POP (<60km, <5ms), RAN Cluster POP (<30km, <2ms), RAN BBU POP (<20km, <1ms), and RAN RU POP. The architecture is divided into three scenarios: Scenario C, Scenario C.1, and Scenario C.2. Scenario C shows a Core breakout, Sec-GW1, UPF1, O-CU-UP, Sec-GW2, UPF2, Local breakout, O-DU, BBU, and O-RU. Scenario C.1 shows a Core breakout, Sec-GW3, UPF3, O-CU-UP1, Sec-GW1, UPF1, Local breakout1, O-CU-UP2, Sec-GW2, UPF2, O-DU, BBU, and O-RU. Scenario C.2 shows a Core breakout1, Core breakout2, Sec-GW3, UPF3, Sec-GW4, UPF4, O-CU-UP1, Sec-GW1, UPF1, Local breakout1, O-CU-UP2, Sec-GW2, UPF2, O-DU1, BBU1, O-DU2, BBU2, and O-RU. The diagram also indicates the use of IPSEC, Split 2, and Split 7.2x. A 'KDDI input' box is shown in the top right. The diagram is labeled '⇒Phase 2' and '⇒Phase 3'.](4619d91bbae1a4a193459a8e9dc880e3_img.jpg) + +Figure B.1-9: Diagram of use cases for phase 2 and 3. The diagram shows a network architecture for Cloud Deployment Scenarios C, C.1, and C.2. It includes a 'Latency' column with distance and delay targets for different network layers: Core DC Central POP (<500km, <30ms), Regional Zone Big POP (<150km, <15ms), Collector Rural Mid POP (<60km, <5ms), RAN Cluster POP (<30km, <2ms), RAN BBU POP (<20km, <1ms), and RAN RU POP. The architecture is divided into three scenarios: Scenario C, Scenario C.1, and Scenario C.2. Scenario C shows a Core breakout, Sec-GW1, UPF1, O-CU-UP, Sec-GW2, UPF2, Local breakout, O-DU, BBU, and O-RU. Scenario C.1 shows a Core breakout, Sec-GW3, UPF3, O-CU-UP1, Sec-GW1, UPF1, Local breakout1, O-CU-UP2, Sec-GW2, UPF2, O-DU, BBU, and O-RU. Scenario C.2 shows a Core breakout1, Core breakout2, Sec-GW3, UPF3, Sec-GW4, UPF4, O-CU-UP1, Sec-GW1, UPF1, Local breakout1, O-CU-UP2, Sec-GW2, UPF2, O-DU1, BBU1, O-DU2, BBU2, and O-RU. The diagram also indicates the use of IPSEC, Split 2, and Split 7.2x. A 'KDDI input' box is shown in the top right. The diagram is labeled '⇒Phase 2' and '⇒Phase 3'. + +Figure B.1-9 Diagram of use cases for phase 2 and 3 + +Table B.1-2 captures assumptions of TN slicing capabilities in each interface for the phase 2 and later. + +Table B.1-2: Scope of the capabilities of O-RAN elements in phase 2 and later + +| ORAN interface | Stream direction | Queue in 4Queue model | Slicing VLAN | Differentiated QoS behavior per slice | +|------------------------------------------------------------|------------------|-----------------------|--------------|---------------------------------------| +| Fronthaul C/U | any | EF (HP) | no | no | +| Fronthaul M-pane,
E1, E2, F1_C, O2, A1,
Xn_c, N2, N4 | any | AF | no | no | +| F1_U | DU > CU-UP | 5QI<>DSCP mapped* | yes** | no | +| F1_U | CU-UP > DU | 5QI<>DSCP mapped | yes** | no | +| N3 (NG) | CU-UP > UPF | 5QI<>DSCP mapped*** | yes | no | +| N3 | UPF > CU-UP | 5QI<>DSCP mapped*** | yes | no | +| Xn_U | any | AF | no | no | + +\*Based on assumption on WG5 and WG6 effort on definition upstream DU > CU\_UP F1\_U 5QI<>DSCP mapping capabilities. + +\*\*Based on assumption on WG5 and WG6 effort on definition F1\_U slicing capabilities (inter-DC risk of missing the March train). + +\*\*\*More on Mapping recommendation in WG9 “RBBN-TFCA-QoS mapping” contribution. + +After this analysis and discussions within ORAN WG9 the conclusion is that NRM as specified in 3GPP TS 28.541 [7] does not provide enough data to create valid transport network slice. + +However, since some of the parameters required to create transport network slice may be extracted from NRM as specified in 3GPP TS 28.541 [7] and some may be translated from SMO expectations, the following scope of work for WG9 and WG10 is proposed: + +- Collect missing parameters in 3GPP TS 28.541 [7] for TN slice creation. +- Propose enhancements of 3GPP TS 28.541 [7] to include OpenModelClass TNSliceSubnet to link EP\_Transport to TN and add options for linking 3GPP subsystems to TN subsystems. +- File ORAN liaison to SA5 in order to augment 3GPP TS 28.541 [7] with missing information and proposed items. +- Align with IETF TN network slice abstraction. +- Define information flows. +- Align ORAN WG1, WG9 and WG10. + +# Annex C (informative): Slicing terminology + +## C.1 Slicing and 3GPP slice modeling terminology awareness + +This clause intends to provide further information and clarified awareness for some of the fundamental network slicing concepts and 3GPP modeling aspects. + +### C.1.1 NSI and NSSI context in 3GPP SA2 and SA5 + +(System Architecture) Network Slice (3GPP SA2): Even though this is a system architecture group, the RAN architecture is out of the scope of SA2. RAN3 owns the RAN architecture. SA2 service-based architecture (SBA) is a functional architecture with mostly service-based interfaces. + +(Management Aspect) Network Slice (3GPP SA5): SA5 describes all the management aspects of a network, which is modular, and model driven. It is a service-based management architecture (SBMA), using service-based API allowing implementations to pick and choose appropriate API and compliance per API. See 3GPP TS 28.533 [i.18]. + +A Network Slice Instance (NSI), a SA2 term, is a set of functions. SA2 also introduced the concept of an instance because there would be more than one slice of the same type for the purpose of scaling. What is managed by an operator is a group of functions (an NSI). + +A NetworkSlice Managed Object Instance (MOI), a SA5 usage, is an object exposing to an external consumer. Once an operator builds a something to satisfy expectations, it needs to build something that is exposed to an external consumer which is a NetworkSlice MOI. Scale in/Scale out is an operation within life cycle management which is under the purview of SA5. In the context of SA5, a NSI is just an attribute carrying signaling “NSI” value semantic. From a management perspective, the abbreviation NSI is sometimes used as a replacement of the proper term NetworkSlice MOI. However, this is just an improper use of terminology. + +A NetworkSliceSubnet MOI is sometimes called an NSSI. However, in SA5, any occurrences of the term NSSI should be perceived as a NetworkSliceSubnet MOI. + +### C.1.2 Name containment limitation + +NSSI stands for NetworkSliceSubnet Instance a.k.a. Managed Object Instance (MOI) of the NetworkSliceSubnet Information Object Class (IOC). + +NetworkSliceSubnet IOC has been introduced to group instances (of any IOC) in a way that is not restricted by the Name Containment (DN) rules. Those name containment rules are specified in 3GPP TS 32.300 [9]. Name containment defines a managing hierarchy. This is ok; however, it restricts the flexibility needed for network slice management (especially for shared network functions). + +This shortcoming of the 3GPP TS 32.300 [9] is addressed by the NetworkSliceSubnet which allows for multiple views or “overlays” to augment the management hierarchies. This grouping is independent of how the network is managed and structured via distinguished names. Note that the NetworkSliceSubnet inherits from the top IOC (3GPP TS 28.541 [7], clause 6.2.2). + +This is illustrated in the following diagram given in figure C.1.2-1: + +#### **TS32.300 Name Containment Rule Limitation** + +Multi-Parent Name containment relationships are **not** supported (inheritance or multiple properties) in TS32.300. + +![Diagram illustrating multi-parent inheritance. Two parent nodes, one blue and one red, are connected by green lines to a single child node, which is a purple circle. The blue parent is labeled 'Parent' in blue text, the red parent is labeled 'Parent' in red text, and the child is labeled 'Child' in blue text.](3cf93bcbc9bd52e47c40eb1b11a53aa1_img.jpg) + +``` + +graph TD + P1((Parent)) --- C((Child)) + P2((Parent)) --- C + style P1 fill:#0000FF,color:#0000FF + style P2 fill:#FF0000,color:#FF0000 + style C fill:#800080,color:#0000FF + +``` + +Diagram illustrating multi-parent inheritance. Two parent nodes, one blue and one red, are connected by green lines to a single child node, which is a purple circle. The blue parent is labeled 'Parent' in blue text, the red parent is labeled 'Parent' in red text, and the child is labeled 'Child' in blue text. + +#### **NetworkSliceSubnet** + +NetworkSliceSubnet allows for multiple views or “overlays” to augment management hierarchies. + +**Figure C.1.2-1: Multi-parent inheritance supported from network slice subnet instance** + +### C.1.3 Network slice subnet is a purposeful generic collection + +The definitions and diagrams that follow are driven from 3GPP 5G NRM specifications in 3GPP TS 28.541 [7]. The 3GPP 5G NRM serves as a foundation for ORAN specification development, and modeling work from which ORAN development aligns to. For further details, please refer to O-RAN WG5 and WG10 specifications. The diagrams in this document utilize elements from the 3GPP 5G NRM but should be fully applicable to the ORAN IM. + +The NetworkSliceSubnet is a purposeful generic collection of objects. The NetworkSliceSubnet can be comprised of a number of managedfunctions, networkservices and EP\_Transport endpoints as shown in the diagram below inspired from the 3GPP TS 28.541 [7], clause 6. + +Three key points that the diagram illustrates is that: + +1. **Generic Collection:** The NetworkSliceSubnet is a purposeful generic collection of objects shown in the diagram. +2. **Recursive:** The NetworkSliceSubnet is a recursive structure which may self-reference NetworkSliceSubnets +3. **Purposeful:** The “purpose” of that generic collection of objects is defined in the SliceProfile. + +NOTE 1: The cardinality between NetworkSliceSubnet and SliceProfile which is written as 1…\* could be an empty list: 1…0 which would imply there is **no** SliceProfile. You could group a set of objects without a profile. Profiles are derived from the SLS. + +NOTE 2: It is stated that it is under consideration in 3GPP that the SliceProfile can become an IOC. + +These points are highlighted in the following diagram given in figure C.1.3-1: + +![Figure C.1.3-1: NetworkSliceSubnet is a purposeful generic collection. This diagram illustrates the structure of NetworkSliceSubnet as a generic collection. It shows a central <> NetworkSliceSubnet box. A <> NetworkSlice box has a 1-to-1 relationship with NetworkSliceSubnet. A <> SliceProfile box has a 1-to-many relationship with NetworkSliceSubnet. NetworkSliceSubnet has a recursive relationship with itself, indicated by a self-loop arrow. NetworkSliceSubnet also has a many-to-many relationship with a box labeled 'Generic Objects: Managed Functions, and EP_Transport Endpoints'. Callouts explain that NetworkSliceSubnet is a generic collection of Objects with a purpose (recursive) and that the NetworkSliceSubnet is recursive. Reference: 3GPP TS28.541 Clause 6.](39685c4b2f487ea8ee72adf4d032169a_img.jpg) + +**Slice Profile** +NetworkSliceSubnet +The purpose of the collection is conveyed in the SliceProfile + +**Generic Collection** +NetworkSliceSubnet +is a generic collection of Objects with a purpose (recursive) + +**Recursive** +NetworkSliceSubnet +The NetworkSliceSubnet is recursive. + +**Generic Objects: Managed Functions, and EP\_Transport Endpoints** + +Reference: 3GPP TS28.541 Clause 6 + +Figure C.1.3-1: NetworkSliceSubnet is a purposeful generic collection. This diagram illustrates the structure of NetworkSliceSubnet as a generic collection. It shows a central <> NetworkSliceSubnet box. A <> NetworkSlice box has a 1-to-1 relationship with NetworkSliceSubnet. A <> SliceProfile box has a 1-to-many relationship with NetworkSliceSubnet. NetworkSliceSubnet has a recursive relationship with itself, indicated by a self-loop arrow. NetworkSliceSubnet also has a many-to-many relationship with a box labeled 'Generic Objects: Managed Functions, and EP\_Transport Endpoints'. Callouts explain that NetworkSliceSubnet is a generic collection of Objects with a purpose (recursive) and that the NetworkSliceSubnet is recursive. Reference: 3GPP TS28.541 Clause 6. + +Figure C.1.3-1: NetworkSliceSubnet is a purposeful generic collection + +### C.1.4 Slicing instance example + +The following diagram given in figure C.1.4-1 shows an example instance of a NetworkSliceSubnet. + +![Figure C.1.4-1: Slicing instance example. This diagram shows a hierarchical instance of a NetworkSliceSubnet. At the top are two NetworkSlice instances (NS1, NS2). NS1 exposes NSS3, and NS2 exposes NSS4. NSS3 and NSS4 are NetworkSliceSubnet instances. NSS3 groups NSS2, and NSS4 groups NSS1. NSS2 groups UPF1, AMF1, and SMF1. NSS1 groups DU1, CUCP1, and CUUP1. DU1 groups NRCelIDU1. CUCP1 groups NRCelIDU1. CUUP1 groups NRCelIDU1. Subnetwork3 is a Subnetwork instance that groups PMJob1, Subnetwork1, and Subnetwork2. PMJob1 groups ME1. Subnetwork1 groups ME2. Subnetwork2 groups ME3. ME1 groups CUUP1. ME2 groups CUUP1. ME3 groups CUUP1. CUUP1 groups NRCelIDU1. The diagram uses various relationship types like 'exposes', 'groups', and 'names' to show the structure.](31b133db52549266cf81ce5fe3f68ab4_img.jpg) + +Figure C.1.4-1: Slicing instance example. This diagram shows a hierarchical instance of a NetworkSliceSubnet. At the top are two NetworkSlice instances (NS1, NS2). NS1 exposes NSS3, and NS2 exposes NSS4. NSS3 and NSS4 are NetworkSliceSubnet instances. NSS3 groups NSS2, and NSS4 groups NSS1. NSS2 groups UPF1, AMF1, and SMF1. NSS1 groups DU1, CUCP1, and CUUP1. DU1 groups NRCelIDU1. CUCP1 groups NRCelIDU1. CUUP1 groups NRCelIDU1. Subnetwork3 is a Subnetwork instance that groups PMJob1, Subnetwork1, and Subnetwork2. PMJob1 groups ME1. Subnetwork1 groups ME2. Subnetwork2 groups ME3. ME1 groups CUUP1. ME2 groups CUUP1. ME3 groups CUUP1. CUUP1 groups NRCelIDU1. The diagram uses various relationship types like 'exposes', 'groups', and 'names' to show the structure. + +Figure C.1.4-1: Slicing instance example + +As a concrete example given in figure C.1.4-1, the above diagram shows instances of managed functions and network slice subnets. Depicted are two network slices (NS1, NS2), with their associated NetworkSliceSubnets, core and RAN managed function components. The picture illustrates that NetworkSliceSubnets are generic groupings of objects. These relationships are indicated by the <> tag. This diagram shows two eMBB network slices that are providing two different services with different throughput SLA requirements within the network of the same service provider (PLMN-A). + +Notice that the NetworkSliceSubnets have SliceProfiles associated with them in this example. The illustration also highlights how some name containment relationships (3GPP TS 32.300 [9]). These are indicated by the <> tag. Notice that NSS2 (NetworkSliceSubnet #2) is a collection of 5G core components (UPF1, AMF1, SMF1); and that NSS1 is a collection of 5G RAN components (DU1, CUCP1, CUUP1, NRCellDU1, NRCellCU1). NSS3 and NSS4 are the NetworkSliceSubnets that expose the “stitched” groupings. The NSS3/NSS4 will have a slice profile that reflects the entire SLA/SLS represented by the service profile. While NSS1/NSS2 will have portions of the entire SLS pertaining to the corresponding (e.g. transport, RAN, core) parts of the slice. This illustrates that the “stitching” occurs at the OSS / network management layer not at the BSS layer where slice orchestration happens. Slice instances at the BSS, the subnets are handled as the management layers. + +### C.1.5 NSSI slice profile and PLMNInfo + +The “purpose” of the NetworkSliceSubnet MOI is given in the SliceProfile which is associated with it. It may be associated with a particular network slice or a group of network slices. The association is accomplished through the pLMNInfoList attribute of the SliceProfile. The Slice Profile is a data type that represents the requirements or purpose of the generic collection instance that may support one or more NetworkSliceSubnet instances. For an end-to-end Network Slice to exist, it is expected that it would have an associated slice profile containing a pLMNInfoList. + +NOTE: A NetworkSliceSubnet may be just a generic collection of objects not associated with an End-to-End Network Slice. In this case, there may not be a slice profile associated with NetworkSliceSubnet. + +Both 3GPP Release 16 and 3GPP Release 17 5G NRM have the SliceProfile, therefore 3GPP TS 28.541 [7] shall be used for further details. This is illustrated in the following diagram given in figure C.1.5-1: + +![Diagram comparing Slice Profile attributes for 3GPP Release 16 and 3GPP Release 17. Both profiles include a pLMNInfoList attribute, which is highlighted with a red box. The diagram also includes a text box explaining the purpose of the pLMNInfoList attribute.](af390dd7b3278195fc2d70b21b567b65_img.jpg) + +**TS28.541 3GPP Release 16** + +3GPP TS28.541 (Release 16) Clause 6.3.2 / 6.3.4.2 + +**Slice Profile** + +| ATTRIBUTE NAME | +|----------------------| +| sliceProfileId | +| pLMNInfoList | +| perfReq | +| maxNumberOfUEs | +| coverageAreaTAList | +| latency | +| uEMobilityLevel | +| resourceSharingLevel | + +**TS28.541 3GPP Release 17** + +3GPP TS28.541 (Release 17) Clause 6.3.2 / 6.3.4.2 + +**Slice Profile** + +| ATTRIBUTE NAME | +|-----------------------| +| sliceProfileId | +| pLMNInfoList | +| CNSliceSubnetProfile | +| RANSliceSubnetProfile | +| TopSliceSubnetProfile | + +**SLICE PROFILE::pLMNInfoList** + +The “purpose” of a NetworkSliceSubnet MOI may be associated with a particular slice / group of slices. The association is done via pLMNInfoList attribute of SliceProfile (slice profile represents the purpose of the collection instance, the purpose may be to support one or more slices). + +Diagram comparing Slice Profile attributes for 3GPP Release 16 and 3GPP Release 17. Both profiles include a pLMNInfoList attribute, which is highlighted with a red box. The diagram also includes a text box explaining the purpose of the pLMNInfoList attribute. + +**Figure C.1.5-1: Slice Profile contains a List of PLMNInfo** + +### C.1.6 Managed functions have a list of PLMNInfo + +The concrete managed functions, notably the gNBCUUPFunction, NRCellCU and NRCellDU each can have a list of PLMNInfo attributes. Concrete managed functions are configured with the slice information via the pLMNInfoList attribute. It is mainly used for signaling. Additionally, the concrete managed function becomes associated with a network slice. + +There are two possible error scenarios: + +First, a managed function can be configured with a particular entry in the pLMNInfoList but it is not member of any network slice subnets associated with profiles containing the same entry in their pLMNInfoList (signaling configured, management association missing). + +Second, a managed function cannot be configured with a particular entry in the pLMNInfoList but is a member of a network slice subnet associated with profiles containing this particular entry (management association present, signaling configuration missing). + +This is illustrated in the following diagram given in figure C.1.6-1: + +![Diagram illustrating managed functions and their attributes. It shows three boxes: GNBCUUPFunction, NRCellCU, and NRCellDU. Each box is associated with a table of attributes. GNBCUUPFunction has attributes gNBCUUPId and pLMNInfoList. NRCellCU has attributes cellLocalId and pLMNInfoList. NRCellDU has attributes cellLocalId, operationalState, administrativeState, cellState, and pLMNInfoList. A red box at the bottom contains a note about the pLMNInfoList attribute.](29a23bc491493b0b4b57bc9674761ab6_img.jpg) + +**GNBCUUPFunction** + +4.3.3 GNBCUUPFunction + +| Attribute name | +|----------------| +| gNBCUUPId | +| pLMNInfoList | + +**NRCellCU** + +4.3.4 NRCellCU + +| Attribute name | +|----------------| +| cellLocalId | +| pLMNInfoList | + +**NRCellDU** + +4.3.4 NRCellDU + +| Attribute name | +|---------------------| +| cellLocalId | +| operationalState | +| administrativeState | +| cellState | +| pLMNInfoList | + +**(Concrete managed functions)::pLMNInfoList** +Concrete managed functions are configured with the slice information via the pLMNInfoList attribute. It is mainly used for signaling. Additionally, the concrete managed function becomes associated with a Network Slice. + +Diagram illustrating managed functions and their attributes. It shows three boxes: GNBCUUPFunction, NRCellCU, and NRCellDU. Each box is associated with a table of attributes. GNBCUUPFunction has attributes gNBCUUPId and pLMNInfoList. NRCellCU has attributes cellLocalId and pLMNInfoList. NRCellDU has attributes cellLocalId, operationalState, administrativeState, cellState, and pLMNInfoList. A red box at the bottom contains a note about the pLMNInfoList attribute. + +**Figure C.1.6-1: Managed functions have a list of PLMNInfo** + +### C.1.7 Single Network Slice Selection Assistance Information (S-NSSAI) + +A Single Network Slice Selection Assistance Information (S-NSSAI) is used to define a slice. It is a 32-bit number defined by 3GPP TS 23.003 [i.2], clause 28.4.1. S-NSSAI is comprised of Slice / Service Type (SST) and Slice Differentiator (SD). SST have values 0 to 127 standards reserved and 128 values are operator defined. These are specified in 3GPP TS 23.501 [2]. The standardized SST values are specified in 3GPP TS 23.501 [2], clause 5.15.2.2. + +# Annex D (informative): Multi-operator slice RAN management services exposure + +## D.1 RAN management services exposure for multi-operator slice + +Sharing of RAN resources is one of the key requirements for Mobile Network Operators (MNO) to reduce the RAN infrastructure cost and increase profitability, while enhancing the coverage. Currently O-RAN drives the RAN sharing models and associated considerations through WG1 Use Cases Detailed Specification Use Case 7: RAN Sharing which focus on the MORAN (Multi Operator RAN) scenario and sharing computing resources (for more details 3GPP TS 22.261 [1] shall be used). The goal of the existing RAN Sharing use case is to enable multiple operators to share the same O-RAN infrastructure wherein each operator utilizes a separate carrier, while allowing them to remotely configure and control the shared resources via a remote O1, O2 and E2 interface. + +While the RAN Sharing use case set the premise for sharing the infrastructure and extending the management interfaces, the use case does not clearly depict the network slicing scenarios especially offering and usage of RAN objects related to network slicing in context of relation between multiple operators. The need for such a slice usage consumption /offering scenario is depicted in 3GPP specification 3GPP TR 28.824 [i.7], 3GPP TR 28.801 [i.3], 3GPP TS 28.530 [23] and other industry initiatives like 5GPPP Slicenet [i.10] project. Specifically, 3GPP TR 28.824 [i.7] depicts the management capability exposure across multiple operators, especially Network Operator (NOP) role played by multiple operator organizations – one offering RAN objects related to network slicing and other using the RAN objects related to network slicing to establish an end-to-end slice. Few examples of business use cases are depicted below: + +- Cross MNO Model of offering and usage of RAN objects related to network slicing + - Two MNOs get into agreement in a scenario where one of the MNOs do not have spectrum or coverage in a particular region (such as foreign country, remote areas, out of service area) to share RAN resources. The arrived solution to share RAN is to utilize RAN objects related to network slicing to fix coverage gaps. E.g., network slice consisting of core objects belonging to MNO1, and RAN objects belonging to MNO2. + - Many MNOs form a consortium and share RAN resource through bulk provisioning of RAN objects related to network slicing that can be offered on demand for subscription to address the needs of consortium participating MNOs (for example to address the emergency, disaster response). + - MVNO relying on multiple MNOs. Each MNO offers its RAN resources as RAN objects related to network slicing. +- MNO and Hyperscale Public Cloud Provider slice consumption offering model + - There is a market trend of collaboration between Hyperscale Public Cloud companies and MNOs in which Hyperscalers count on access network infrastructure owned by MNO, while utilizing the edge and core network services using their own or partner services. In this model the RAN objects related to network slicing is offered to the Hyperscalers and integrated to offer a unified service. + +Considering that standards, related marketing trends and described cases with multiple parties involved, there is a great value to streamline parties' interaction with respective O-RAN specification activities. + +From an O-RAN standardization perspective following three aspects need to be considered in context of these use case models: + +- Exposure of management services providing lifecycle management, CM, FM, PM, performance analytics and other management capabilities of RAN logical instances (as a collected group of RAN objects related to network slicing) for usage of RAN objects related to network slicing in context of relation between multiple operators + +- Exchange and mapping of resource identifiers corresponding to a collected group of RAN objects related to network slicing for it to be composed into an end-to-end slice. +- Governance of the exposed O-RAN slice subnet management services for them to be made available externally in a secured and manageable manner. + +NOTE 1: Logical instances as collected group of RAN objects related to network slicing implies representation of a group of logical components within each RAN node that collectively provide required characteristics of network slice at RAN part which is commonly called in the O-RAN Slicing Architecture Specification as O-RAN slice subnet. + +NOTE 2: Direct SMO exposure to external slice management systems across MNOs assumes prior business agreement (contract) between parties. + +NOTE 3: Correct interpretation of FM and PM data may require prior interface agreements with exchange of related data (e.g., specifications of PM, FM problem types, MIB files). + +NOTE 4: “Multi-Operator slice” is a term used to represent a concept of end-to-end network slice that uses O-RAN slice subnet instances (collected group of RAN objects related to network slicing) provided by MNO in shared RAN resources. As needed, the partner operator would define its PLMN specific network slice (as per 3GPP TS 23.501 [2], slice is identified by S-NSSAI within a specific PLMN ID but not multiple PLMN IDs) in that end-to-end slice. + +### D.1.1 Management services exposure for multi-operator slice - Relevant standards + +- 3GPP TS 28.530 [23], clause 4.1.6 Network Slice as a Service (NSaaS): Explains the concept of NSaaS offered by CSP to CSC and the ability of the CSC to manage the network slice as manager via management interface exposed by the CSP. Further, the CSC is also allowed to offer their own services (e.g., communication services) on top of the network slice obtained from the CSP. +- 3GPP TS 28.533 [i.18], clause A.3 Utilization of management services by Exposure Governance Management Function (EGMF): Explains the management capability of EGMF, especially exposure governance and also depicts an example of exposing the Management Function (MnF) capability through the EGMF to MnF from another operator or to 3rd Party. The standardization of EGMF in 3GPP is not mature and require further elaboration. +- 3GPP TS 28.824 [i.7]: Focused study on network slice management capability exposure. Highlights the general concept of exposure of management service (e.g., via BSS, without going through BSS), the roles related to network management capability exposure, types of interfaces for exposure of network slice. Further, the study item also highlights a use cases and scenario of exposure of network slice as a service, wherein RAN slice is offered as a product to CSP. This informative clause reuses the concepts defined in 3GPP 28.824 [i.7] and investigate the O-RAN specific impacts. +- 3GPP TR 28.811 [i.8]: Study on the network slice management enhancements. This study item covers potential enhancements to slice management such as multi-operator relationships in network slice management, concepts like roaming, network slice isolation, edge computing, network slice specific authentication, management data isolation for different Network Slice Consumers (NSCs). One relevant scenario considered in the study item is network slice using multiple networks scenario which highlights two potential options – a) Solution based on Network Slice as a Service (NSaaS) – enhancements to NetworkSlice IOC or new ExternalNetworkSlice IOC and b) Solution based on Network Slice Subnet as a Service (NSSaaS) - enhancements to NetworkSliceSubnet IOC or new ExternalNetworkSliceSubnet IOC. +- 3GPP TR 28.801 [i.3]: Study on management and orchestration of network slicing for next generation network. Clause 5.1.8.2 describes the scenario of creating an end-to-end network slice instance across multiple operators. Similarly, clause 5.1.9 describes a scenario of limited level of management exposure for multiple network slice instances. + +- 3GPP TR 23.700-99 [i.9]: Study on Network Slice Capability Exposure for Application Layer Enablement (NSCALE). This study identifies key issues, solutions, and potential requirements to enable exposure of network slice management capabilities applied to vertical industries (exposure to application function). This study item highlights some key requirements that may be relevant for the external management of O-RAN slice subnet – such as the ones described in clause 4.1.1 [i.9] - The application enablement layer should support interaction with 3GPP network management system to consume network slice management service. + +### D.1.2 Concepts of management services exposure for multi-operator slice + +This clause summarizes the key concepts related to management services exposure for multi-operator slice. These concepts build on those already defined in 3GPP TR 28.824 [i.7]. + +- exposed Management Service (eMnS): The SMO has a certain set of capabilities. Some of the capabilities of the SMO need to be exposed northbound. +- eMnS producer: The logical function of SMO that provides management service that can be consumed by an eMnS consumer. +- eMnS consumer: The logical entity outside the administrative and trust boundaries of SMO that consumes exposed management service. +- MnS producer: The logical function of SMO that provides management service(s) that can be discovered and consumed within a MNO's administrative and trust boundaries. +- eMnS exposure: Set of procedures that make available management service in SMO for external consumer. This can include registration of service producers in external exposure functions, publishing of a management service for external exposure, authentication, and authorization of eMnS consumer, discovery of required eMnS based on selection criteria defined by eMnS consumer. +- eMnS discovery: Discovery of the eMnS producer management services by an eMnS consumer based on its selection criteria. +- SMO external exposure functions: Abstract notion to be used in use cases and scenarios description consolidating SMO services providing capabilities to support eMnS exposure and potentially other similar services. SMO external exposure function is used as an example to logically represent this set of capabilities. + +NOTE 1: The discovery service can be realized using either an existing service discovery functions in SMO or to be defined new SMO external exposure functions or a gateway function as defined in 3GPP 28.533 [i.18] like EGMF. The exposure of eMnS capabilities may also adopt the approach in 3GPP TR 23.700-99 [i.9] leveraging the Network Slice Capability Enablement Server (NSCE-S) in combination with EGMF. + +NOTE 2: Since SMO external exposure function is not limited to eMnSs related to RAN network slicing, it is assumed to be addressed within the scope of WG1 Architecture work and is not supposed to be formally defined in this specification. An extensive functional description is beyond the scope of this specification. Some potential references for realizing the functionality of SMO external exposure functions are – CAPIF (3GPP TS 23.222 [i.5], 29.222 [i.6]), EGMF (3GPP 28.533 [i.18]) etc. + +- Operator business roles: + - Managed Network Operator (MNO): provides or consumes management services related to RAN slicing. + - E\_NSSMS\_C (External consumer of MnS related to RAN slicing): Operator who discovers and consumes eMnSs related to RAN slicing. + - E\_NSSMS\_P (Provider of external MnS related to RAN slicing): Operator who is exposes and provides eMnSs related to RAN slicing. + +### D.1.3 Management aspects of external exposure of MnS related to RAN slicing + +#### D.1.3.1 General + +External exposure of MnS related to RAN slicing may be treated as a particular case of the generic service exposure existing in the industry and covered in standard specifications like 3GPP Common API Framework [i.5], [i.6]. Therefore, many aspects related to generic exposure architecture may be applicable to the external exposure of MnS related to RAN slicing case as well. + +According to 3GPP CAPIF framework, clear separation of registry specific aspects and service specific aspects is recommended in functional model, architecture, and procedures. In CAPIF architecture the CAPIF core function consolidates all registry specific aspects and enable service APIs from both the MNO trust domain and the 3rd party trust domain having business relationship with MNO, while service specific aspects are covered by API provider functions (API Exposing Function (AEF), API Publishing Function (APF) and API Management Function (AMF)). + +Similarly, management of external exposure of MnS related to RAN slicing would include two categories of aspects: + +- related to service specific aspects (i.e., actual processing of service requests to exposed management services (eMnSs) from E\_NSSMS\_C e.g., service endpoint termination, throttling, translation between external and internal information, re-exposure of service operations and events, topology hiding, routing, etc.) +- related to registry and catalog specific aspects (i.e., capabilities to manage various data records and profiles to support registration, discovery, publishing, identity management, authentication, authorization, access policies, data translation rules, topology hiding policies etc.) + +While the CAPIF framework helps to reuse registry specific capabilities for various API exposure scenarios, it presumes decomposed architecture with additional interactions between CAPIF Core Function (CCF) and API provider functions (AEF, APF, AMF) which adds more complexity and need not to be always preferred. + +With regards to possible impact on capabilities of SMO management services, at least two alternative options can be considered for management of external exposure of MnS related to RAN slicing: + +- Option 1: Consolidation of exposure capabilities (see figure D.1.3.1-1). Internal SMO management services are off-loaded from capabilities of external exposure as much as possible, i.e., service-related aspects are as well managed by dedicated category of SMO external exposure services. + +![Figure D.1.3.1-1: Option 1: Consolidation of exposure capabilities. This diagram illustrates the consolidation of exposure capabilities between E_NSSMS_C and SMO/E_NSSMS_P. E_NSSMS_C contains an 'External consumer of MnS related to RAN slicing'. SMO/E_NSSMS_P contains 'SMO external exposure functions' (which include 'SMO external exposure services', 'Registry Capabilities', and 'service specific aspects capabilities') and 'SMO Functions' (which include 'SMO Management Services'). Interactions are shown: 'Authentication, discovery, ...' from the consumer to SMO external exposure services; 'Operations' from the consumer to SMO Management Services; 'Capabilities of SMO external exposure services' from SMO external exposure services to SMO Functions; and 'Capabilities of SMO Management Services' from SMO Management Services to SMO Functions. A legend at the bottom indicates that open circles represent 'Services producing' and open rectangles represent 'Services consuming'.](d78d6db05a11fc37e743cf2b10000870_img.jpg) + +Figure D.1.3.1-1: Option 1: Consolidation of exposure capabilities. This diagram illustrates the consolidation of exposure capabilities between E\_NSSMS\_C and SMO/E\_NSSMS\_P. E\_NSSMS\_C contains an 'External consumer of MnS related to RAN slicing'. SMO/E\_NSSMS\_P contains 'SMO external exposure functions' (which include 'SMO external exposure services', 'Registry Capabilities', and 'service specific aspects capabilities') and 'SMO Functions' (which include 'SMO Management Services'). Interactions are shown: 'Authentication, discovery, ...' from the consumer to SMO external exposure services; 'Operations' from the consumer to SMO Management Services; 'Capabilities of SMO external exposure services' from SMO external exposure services to SMO Functions; and 'Capabilities of SMO Management Services' from SMO Management Services to SMO Functions. A legend at the bottom indicates that open circles represent 'Services producing' and open rectangles represent 'Services consuming'. + +**Figure D.1.3.1-1: Option 1: Consolidation of exposure capabilities** + +- Option 2: Decomposition of exposure capabilities (see figure D.1.3.1-2). Internal SMO management services are aware of exposure and enriched with at least service specific aspects to proceed requests from external consumer of MnS related to RAN slicing following identity and policy information managed in SMO external exposure services responsible for registry specific aspects. + +![Figure D.1.3.1-2: Option 2: Decomposition of exposure capabilities. This block diagram shows the interaction between an external consumer and SMO services. The top box, E_NSSMS_C, contains the 'External consumer of MnS related to RAN slicing'. It connects via 'Authentication, discovery, ...' to the 'SMO external exposure functions' within the SMO/E_NSSMS_P box. These functions include 'SMO external exposure services' and 'Registry Capabilities'. Below this, 'Capabilities of SMO external exposure services' and 'Capabilities of SMO Management Services' are shown, which connect to 'SMO Functions' containing 'SMO Management Services' and 'service specific aspects capabilities'. A vertical line labeled 'Operations' also connects the consumer to the SMO functions. A legend at the bottom indicates that open circles represent 'Services producing' and open rectangles represent 'Services consuming'.](db9a835541f84425c11ea43a7f337a78_img.jpg) + +Figure D.1.3.1-2: Option 2: Decomposition of exposure capabilities. This block diagram shows the interaction between an external consumer and SMO services. The top box, E\_NSSMS\_C, contains the 'External consumer of MnS related to RAN slicing'. It connects via 'Authentication, discovery, ...' to the 'SMO external exposure functions' within the SMO/E\_NSSMS\_P box. These functions include 'SMO external exposure services' and 'Registry Capabilities'. Below this, 'Capabilities of SMO external exposure services' and 'Capabilities of SMO Management Services' are shown, which connect to 'SMO Functions' containing 'SMO Management Services' and 'service specific aspects capabilities'. A vertical line labeled 'Operations' also connects the consumer to the SMO functions. A legend at the bottom indicates that open circles represent 'Services producing' and open rectangles represent 'Services consuming'. + +**Figure D.1.3.1-2: Option 2: Decomposition of exposure capabilities** + +NOTE: CAPIF is originated out of 3GPP SA6 WG (application enablement and critical communication applications group for vertical markets) and 3GPP CT WG3 (design and specification of the Northbound APIs between the vertical application servers and the core network) which are not dedicated to management specifications design. Management specifications design is in responsibility of 3GPP SA5 WG (Management, Orchestration and Charging for 3GPP systems) + +SA5 WG gives high level definition [i.18] of Exposure Governance Management Function (EGMF) as a management function with the role of management service exposure governance (i.e., abstraction, simplification, filtering, etc.). Functional model and requirements are not yet defined for EGMF. 3GPP conducts the study ([i.7] not yet finalized) suggesting possible roles of EGMF and possible solutions for combined CAPIF/EGMF architecture applied to management domain. One of the considered architectures is where EGMF consolidates the registry specific functions (CAPIF core function) and API provider domain functions. + +### D.1.4 Multi-operator slice: High-level use cases and potential requirements for exposure fo MnS related to O-RAN slicing + +As noted above, the term “multi-operator slice” is used here to represent a concept of end-to-end network slice that uses O-RAN slice subnet instances (collected group of RAN objects related to network slicing) provided by MNO in shared RAN resources. As needed, the partner operator would define its PLMN specific network slice (as per 3GPP TS 23.501 [2], slice is identified by S-NSSAI within specific PLMN ID but not multiple PLMN IDs) in that end-to-end slice. + +This clause provides the high-level use cases and potential requirements for controlled external exposure of of MnS related to RAN slicing. + +#### D.1.4.1 Registration of producers of MnSs related to RAN slicing for external exposure + +##### D.1.4.1.1 Background and goal of the use case + +In order to expose MnS related to RAN slicing externally SMO functions responsible for external exposure (SMO external exposure functions) need to be aware of producer of these services in SMO. This can be achieved by registering producers of respective MnSs in SMO external exposure functions. + +##### D.1.4.1.2 Description + +###### Pre-condition + +- There are existing trust relations between SMO external exposure functions and SMOF that is a producer of MnS related to RAN slicing. +- SMOF can reach SMO external exposure services (as one of the possibilities, SMOF gets informed of SMO external exposure services capabilities and service end-points through preliminary registration of SMO external exposure functions as a producer of SMO external exposure services in SMOF responsible for service registration and management). + +NOTE: SMOF responsible for service registration and management is not yet formally defined in SMO architecture. + +- SMOF playing a role of a producer of MnS related to RAN slicing determines its MnSs are required to be exposed externally. +- SMO function responsible for external exposure does not have information about the producer of MnSs related to RAN slicing. + +###### High level procedure (see figure D.1.4.1.2-1) + +1. SMOF playing a role of a producer of MnS related to RAN slicing requests SMO external exposure services to register its MnSs. +2. SMO external exposure services producer creates registry record for the producer of MnSs related to RAN slicing containing data about available MnSs and additional data (e.g., id, end-point URIs, MnS producer profile with supported MnSs, load level, heartbeat etc). +3. SMO external exposure services producer acknowledges the successful registration or failure. SMO external exposure function may subscribe to SMOF status or SMOF sets pushing status heartbeat. + +![Flow of registration of MnS related to RAN slicing for external exposure diagram](37729fb91b79a1d5c636538a3e1c256c_img.jpg) + +The diagram illustrates the flow of registration for MnSs related to RAN slicing. It is divided into two main sections: 'SMO/ E\_NSSMS\_P' at the top and 'SMO Functions' at the bottom. Within 'SMO/ E\_NSSMS\_P', there is a dashed box labeled 'SMO external exposure functions' containing 'SMO external exposure services' and 'Registry Capabilities'. The 'SMO Functions' section contains a box labeled 'producer of MnS related to RAN slicing' which includes three 'MnS' entities. The process flow is indicated by numbered steps: 1. A request arrow from 'producer of MnS' to 'SMO external exposure services'. 2. A response arrow from 'Registry Capabilities' back to 'SMO external exposure services'. 3. A response arrow from 'SMO external exposure services' back to 'producer of MnS'. A 'No Record' label is shown near step 1, and a 'Record created' label is shown near step 2. + +Flow of registration of MnS related to RAN slicing for external exposure diagram + +**Figure D.1.4.1.2-1. Flow of registration of MnS related to RAN slicing for external exposure** + +###### Post-condition + +SMO external exposure services producer has created the registry record for a producer of MnS related to RAN slicing. + +##### D.1.4.1.3 Potential requirements + +REQ-SL-EXP-FUNxx SMO should support a capability to register MnSs that are required to be exposed externally. + +REQ-SL-EXP-FUNxx SMO should support a capability to discover the MnS of the function that provides registration for MnSs that are required to be exposed externally. + +REQ-SL-EXP-FUNxx SMO should support a capability to store, query, update, and deliver information about producer of MnSs that can be exposed externally. + +*Editor's note: The above requirements are intentionally not yet numbered and will be numbered if/when they become normative requirements.* + +#### D.1.4.2 Discovery of producers of MnS related to RAN slicing for external exposure + +##### D.1.4.2.1 Background and goal of the use case + +In order to expose capabilities of MnS related to RAN slicing externally SMO external exposure functions need to be aware of producer of these services in SMO. This can be achieved by discovering producers of respective MnSs by querying SMOF responsible for service registration and management and providing common registration service to MnSs). + +NOTE: SMOF responsible for service registration and management is not yet formally defined in SMO architecture. + +##### D.1.4.2.2 Description + +###### Pre-condition + +- There are existing trust relations between SMO external exposure function and SMOF responsible for service registration and management. +- SMO external exposure function can reach SMOF responsible for service registration and management. +- SMOF playing the role of a producer of MnS related to RAN slicing registered its MnSs in SMOF responsible for service registration and management. +- SMO external exposure function determines MnSs that are required to be exposed externally. +- SMO external exposure function does not have information of the producer of MnSs that are required to be exposed externally. + +###### High level procedure (see figure D.1.4.2.2-1) + +1. SMO external exposure function requests SMOF responsible for service registration and management to discover a producer of specific MnSs by providing filter criteria. +2. SMOF responsible for service registration and management applies filter criteria to the existing registry records for MnS producers. +3. SMOF responsible for service registration and management provides response with details on producers of matching MnSs. + +![Figure D.1.4.2.2-1: Flow of discovery of MnS related to RAN slicing for external exposure. The diagram shows the interaction between SMO external exposure functions and SMO Functions. The SMO external exposure functions include a Registry Capabilities block with 'No Record' (orange) and 'Record created' (green) states. The SMO Functions block includes a 'producer of MnS related to RAN slicing' and a 'service registration and management SMOF'. The flow is: 0. 'No Record' state; 1. Request from SMO Functions to SMO external exposure functions; 2. Response from SMO external exposure functions to SMO Functions; 3. 'Record created' state.](80ea99ccdfaddf8eff7067c4326526cd_img.jpg) + +Figure D.1.4.2.2-1: Flow of discovery of MnS related to RAN slicing for external exposure. The diagram shows the interaction between SMO external exposure functions and SMO Functions. The SMO external exposure functions include a Registry Capabilities block with 'No Record' (orange) and 'Record created' (green) states. The SMO Functions block includes a 'producer of MnS related to RAN slicing' and a 'service registration and management SMOF'. The flow is: 0. 'No Record' state; 1. Request from SMO Functions to SMO external exposure functions; 2. Response from SMO external exposure functions to SMO Functions; 3. 'Record created' state. + +**Figure D.1.4.2.2-1: Flow of discovery of MnS related to RAN slicing for external exposure** + +###### Post-condition + +SMO external exposure function has obtained the registry records for a producer of the MnSs that are required to be exposed externally as per requested filter criteria. + +##### D.1.4.2.3 Potential requirements + +REQ-SL-EXP-FUNxx SMO should support a capability for an authorized SMOF to discover MnSs that are required to be exposed externally. + +REQ-SL-EXP-FUNxx SMO should support a capability for an authorized SMOF to obtain information about MnSs that are required to be exposed externally based on criteria specified by that SMOF. + +*Editor's note: The above requirements are intentionally not yet numbered and will be numbered if/when they become normative requirements.* + +#### D.1.4.3 Registration of eMnS consumer + +##### D.1.4.3.1 Background and goal of the use case + +A consumer outside the trust and administrative boundary of the SMO needs to be authenticated and authorized using the identity data of the consumer in order to allow access to exposed management services. Consumer identity data needs to be registered at SMO. Traditionally, in the industry, registration is performed manually at producer side. It may also be performed automatically. Automatic registration presumes mechanisms for secured communication, for instance, certificate check and encryption based on server (SMO) certificate. Registration capabilities also presume management of records containing consumer account data including but not limited to consumer credentials, consumer roles and rights it is authorized to. + +NOTE: In case of manual registration, consumer details corresponding to the registration are created through SMO operational procedures initiated by a human operator. By completion of registration procedures exposed management services consumer is provided with credentials and is aware of authentication method and access rights. + +##### D.1.4.3.2 Description + +###### Pre-condition + +- eMnS consumer can reach SMO external exposure. +- SMO function responsible for external exposure does not have consumer account data record for eMnS consumer. + +###### High level procedure (see figure D.1.4.3.2-1) + +1. eMnS consumer requests SMO external exposure services to register itself and provides information about intended scope of management services to consume. +2. SMO external exposure services producer performs eligibility check based on provided by eMnS consumer information and makes a decision on request approval. +3. In case of positive result, SMO external exposure services producer creates registry record for the eMnS consumer containing data about intended and authorized management services to consume, credentials and authentication method. +4. SMO external exposure services producer acknowledges the successful registration and provide credentials data to eMnS. eMnS consumer may subscribe to status of SMO external exposure function or SMO external exposure function sets pushing status heartbeat. + +![Figure D.1.4.3.2-1: Flow of registration of consumer of eMnS related to RAN slicing. The diagram shows the interaction between E_NSSMS_C (External consumer of MnS related to RAN slicing) and SMO/E_NSSMS_P (SMO external exposure functions). The SMO/E_NSSMS_P block contains SMO external exposure services and Registry Capabilities. The SMO external exposure services block contains a 'No Record' state (0) and a 'Record created' state (3). The Registry Capabilities block contains an 'Eligibility check passed' state (2). The SMO/E_NSSMS_P block is connected to SMO Functions, which includes a producer of MnS related to RAN slicing and three MnS instances. The flow is as follows: 1. Request from consumer to SMO external exposure services. 2. Eligibility check passed. 3. Record created. 4. Acknowledgment from SMO external exposure services to consumer.](2a81f7aa3e36f84d971bfca1687419ff_img.jpg) + +Figure D.1.4.3.2-1: Flow of registration of consumer of eMnS related to RAN slicing. The diagram shows the interaction between E\_NSSMS\_C (External consumer of MnS related to RAN slicing) and SMO/E\_NSSMS\_P (SMO external exposure functions). The SMO/E\_NSSMS\_P block contains SMO external exposure services and Registry Capabilities. The SMO external exposure services block contains a 'No Record' state (0) and a 'Record created' state (3). The Registry Capabilities block contains an 'Eligibility check passed' state (2). The SMO/E\_NSSMS\_P block is connected to SMO Functions, which includes a producer of MnS related to RAN slicing and three MnS instances. The flow is as follows: 1. Request from consumer to SMO external exposure services. 2. Eligibility check passed. 3. Record created. 4. Acknowledgment from SMO external exposure services to consumer. + +**Figure D.1.4.3.2-1: Flow of registration of consumer of eMnS related to RAN slicing** + +###### Post-condition + +SMO external exposure function has created the consumer account data record for the eMnS consumer and eMnS consumer has received registration confirmation with required data. + +##### D.1.4.3.3 Potential requirements + +REQ-SL-EXP-FUNxx SMO should support a capability to register a consumer of exposed management services. + +REQ-SL-EXP-FUNxx SMO should support a capability to manage lifecycle of account data record (creation, modification, deletion) of a consumer of exposed management services. + +REQ-SL-EXP-FUNxx SMO should support a capability to manage credentials, related roles, and authorized access rights of a consumer of exposed management services. + +REQ-SL-EXP-FUNxx SMO should support a capability for an authorized SMOF to store, query, update, and deliver information about consumer of exposed management services. + +*Editor's note: The above requirements are intentionally not yet numbered and will be numbered if/when they become normative requirements.* + +#### D.1.4.4 Authentication and authorization of eMnS consumer + +##### D.1.4.4.1 Background and goal of the use case + +In order consumer of exposed management services be authenticated and authorized to consume intended scope of MnSs, SMO external exposure functions need to support authentication and authorization processes capabilities relying on identity and authorized rights for the eMnS consumer created during its registration. + +NOTE: Authentication procedures shall comply with all the security requirements as specified in O-RAN.WG11.Security-Protocols-Specification [24]. + +##### D.1.4.4.2 Description + +###### Pre-condition + +- There are existing trust relations between SMO external exposure functions and eMnS consumer. +- eMnS consumer can reach SMO external exposure. +- SMO function responsible for external exposure has consumer account data record for eMnS consumer including credentials, roles, and authorized access rights. + +###### High level procedure (see figure D.1.4.4.2-1) + +1. eMnS consumer initiates authentication by providing its credentials and information on security capabilities to SMO external exposure function. +2. SMO external exposure function selects security method and performs mutual authentication with eMnS consumer. +3. After receiving successful authentication response eMnS consumer may request for permission to access certain exposed management services (otherwise decision on access permission is made based on previously stored data) +4. SMO external exposure function checks access rights in registry record for eMnS consumer and sends authorization response containing access token and scope defining allowed for eMnS consumer exposed management services. + +![Figure D.1.4.4.2-1: Flow of authentication and authorization of eMnS consumer. The diagram shows the interaction between an External consumer of MnS related to RAN slicing (E_NSSMS_C) and SMO external exposure functions (SMO/ E_NSSMS_P). The SMO external exposure functions are connected to SMO Functions, which include a producer of MnS related to RAN slicing and three MnS instances. The flow is numbered 1 to 4: 1. Authentication initiation, 2. Mutual authentication, 3. Access request, and 4. Access rights check. A green box labeled 'access rights check' is shown within the Registry Capabilities of the SMO external exposure functions.](2b3c65b81c20f37a737486fb13043fc9_img.jpg) + +Figure D.1.4.4.2-1: Flow of authentication and authorization of eMnS consumer. The diagram shows the interaction between an External consumer of MnS related to RAN slicing (E\_NSSMS\_C) and SMO external exposure functions (SMO/ E\_NSSMS\_P). The SMO external exposure functions are connected to SMO Functions, which include a producer of MnS related to RAN slicing and three MnS instances. The flow is numbered 1 to 4: 1. Authentication initiation, 2. Mutual authentication, 3. Access request, and 4. Access rights check. A green box labeled 'access rights check' is shown within the Registry Capabilities of the SMO external exposure functions. + +**Figure D.1.4.4.2-1: Flow of authentication and authorization of eMnS consumer** + +###### Post-condition + +SMO external exposure function has authenticated and authorized eMnS consumer to access allowed scope of exposed management services. + +##### D.1.4.4.3 Potential requirements + +REQ-SL-EXP-FUNxx SMO should support a capability for mutual authentication between SMO and consumer of exposed management services. + +REQ-SL-EXP-FUNxx SMO should support a capability for authorization of consumer of exposed management services. + +REQ-SL-EXP-FUNxx SMO should support internal to SMO capability to create, read, update, and delete authorization policies related to exposed management services. + +*Editor's note: The above requirements are intentionally not yet numbered and will be numbered if/when they become normative requirements.* + +#### D.1.4.5 Publishing of eMnS + +##### D.1.4.5.1 Background and goal of the use case + +For an eMnS consumer to consume eMnS, the eMnS needs to be defined, created, and activated in SMO as available for requests from outside the administrative and trust boundaries of SMO. It is also necessary to implement and apply access constraint policies (e.g. access rights, requests rate limitations) to eMnS in accordance with the previous business agreement between E\_NSSMS\_C and E\_NSSMS\_P. + +The eMnS definition relies on the capabilities of MnSs related to RAN slicing that are registered in SMO external exposure services. The definition includes sufficient information for eMnS consuming (e.g. public endpoint URI, version, metadata, protocol, authentication method, resource URIs, operations and their parameters, data format). + +Depending on the use case eMnS may be associated with MnS either directly or indirectly. In case of indirect association eMnS may be an aggregation of a set of MnSs, of a subset of MnS capabilities or group of several MnS subsets. + +eMnS may also be an abstraction formed by transformation to specific external data models, mapping, filtering and enrichment for data and operations of supporting MnSs, in that case publishing may also cover how eMnS is formed. + +NOTE: For the given use case direct association of eMnS to MnS is assumed. + +In general, service publishing includes manual activities that may be streamlined using various DevOps automation tools in conjunction with workflow management systems. + +##### D.1.4.5.2 Description + +###### Pre-condition + +- Business agreement between E\_NSSMS\_C and E\_NSSMS\_P exists. +- SMO external exposure function uses account information of eMnS consumer to authenticate and authorize it. +- SMO external exposure function has information about scope of management services eMnS consumer intends to consume. +- SMO external exposure function has the registry records for producers of MnS related to RAN slicing that may be exposed externally. + +###### High level procedure + +1. SMO administrator gets a task to make a new eMnS available for the E\_NSSMS\_C. + +2. SMO administrator using various DevOps automation tools defines and create eMnS deployment package within SMO external exposure functions. +3. SMO administrator following business agreement information, information in eMnS consumer account data record and eMnS consumer intended scope of consumed management services defines and stores within SMO external exposure function access constraint policies to be applied to the eMnS consumer for the newly created eMnS. +4. SMO administrator deploys and activates an instance of eMnS for it to be available for for the requests from the outside the administrative and trust boundaries of SMO and task of eMnS publishing is reported as completed. + +###### Post-condition + +- eMnS deployment package is prepared and created within SMO external exposure functions. +- Access constraint policies to be applied to the eMnS consumer for the newly created eMnS are prepared and created within SMO external exposure functions. +- An instance of eMnS based on eMnS definition package is deployed and activated within SMO and is available for the consumption by the eMnS consumer from the outside of the administrative and trust boundaries of SMO. + +NOTE: Depending on the progress of De-Coupled SMO or specific implementation need, these capabilities may reside in one of the SMO functions or realized with support of rApps. + +##### D.1.4.5.3 Potential requirements + +REQ-SL-EXP-FUNxx SMO should support a capability to manage lifecycle (creation, modification, deletion) of the exposed management service deployment package that includes sufficient information for consuming that exposed management service (e.g. including but not limited to public endpoint URI, version, metadata, protocol, authentication method, resource URIs, operations and their parameters, data format). + +REQ-SL-EXP-FUNxx SMO should support a capability to manage lifecycle of the access constraint policies (access rights, requests rate limits and other) to be applied to the exposed management service consumer for the exposed management service consumption. + +REQ-SL-EXP-FUNxx SMO should support a capability to manage lifecycle (creation, modification, deletion) of the exposed management service instance. + +*Editor's note: The above requirements are intentionally not yet numbered and will be numbered if/when they become normative requirements.* + +#### D.1.4.6 Discovery of eMnS + +##### D.1.4.6.1 Background and goal of the use case + +For the consumer of exposed management services to be aware of eMnS that are available for consumption, the external exposure function of the SMO needs to be able to support the capability and process of eMnS discovery. For eMnS to be discovered it needs first to be published. Discovery is provided to the authorized consumers of exposed management services. + +Upon discovery, the consumer of exposed management services obtains information on producers and available instances of eMnSs, including service access information for each producer. It may also contain specific instructions on how requests data are expected to be secured and formatted. + +A consumer of exposed management may discover available eMnS with a specific query containing filter criteria to SMO external exposure function or by getting a notification from SMO external exposure function on available eMnS matching notification subscription criteria. + +NOTE: Access to discovery capabilities of SMO may be in itself a subject for the access constraint policies. + +##### D.1.4.6.2 Description + +###### Pre-condition + +- There are existing trust relations between SMO external exposure function and eMnS consumer. +- eMnS consumer can reach SMO external exposure. +- SMO external exposure function has consumer account data record for eMnS consumer including credentials, roles, and authorized access rights. +- eMnS instances are published. +- eMnS consumer does not have information about published eMnS instances or deems the previously stored information needs to be updated. + +###### High level procedure (see figure D.1.4.6.2-1) + +1. eMnS consumer requests SMO external exposure function to discover a producer of specific eMnSs by providing filter criteria. +2. SMO external exposure function applies filter criteria to the existing instances of eMnSs and its producers. +3. SMO external exposure function provides a response with information on producers of matching eMnSs and available instances of eMnSs. + +![Figure D.1.4.6.2-1: Flow of discovery of eMnS by eMnS consumer. The diagram shows the interaction between E_NSSMS_C (External consumer of MnS related to RAN slicing) and SMO/E_NSSMS_P (SMO external exposure functions). E_NSSMS_C sends a request (1) to SMO/E_NSSMS_P. SMO/E_NSSMS_P checks its Registry Capabilities (2) and SMO external exposure services (0 Record exists). SMO/E_NSSMS_P then sends a response (3) back to E_NSSMS_C. A status box indicates 'No Record/Obsolete' (0) and 'Record created/updated' (3).](a1697f3b1349fd1f8b0f0ef7ddfd41ef_img.jpg) + +Figure D.1.4.6.2-1: Flow of discovery of eMnS by eMnS consumer. The diagram shows the interaction between E\_NSSMS\_C (External consumer of MnS related to RAN slicing) and SMO/E\_NSSMS\_P (SMO external exposure functions). E\_NSSMS\_C sends a request (1) to SMO/E\_NSSMS\_P. SMO/E\_NSSMS\_P checks its Registry Capabilities (2) and SMO external exposure services (0 Record exists). SMO/E\_NSSMS\_P then sends a response (3) back to E\_NSSMS\_C. A status box indicates 'No Record/Obsolete' (0) and 'Record created/updated' (3). + +**Figure D.1.4.6.2-1: Flow of discovery of eMnS by eMnS consumer** + +###### Post-condition + +eMnS consumer has an updated information about published eMnS instances it is able to consume. + +##### D.1.4.6.3 Potential requirements + +REQ-SL-EXP-FUNxx SMO should support a capability for an authorized consumer of exposed management services to discover published exposed management services. + +REQ-SL-EXP-FUNxx SMO should support a capability for an authorized consumer of exposed management services to obtain information about published exposed management services based on criteria specified by that consumer of exposed management services. + +REQ-SL-EXP-FUNxx SMO may support capability for an authorized consumer of exposed management services to subscribe to discovery events, get notifications (for example: update, removal, or creation of exposed management service instance in the scope of subscription) and to request health check. + +*Editor's note: The above requirements are intentionally not yet numbered and will be numbered if/when they become normative requirements.* + +# Annex (informative): Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2019.11.13 | 01.00.00 | Draft for template | +| 2020.01.02 | 01.00.01 | Addition of slicing overview, RAN slice SLA assurance use case, general principles | +| 2020.01.08 | 01.00.02 | Addition of initial requirements and architecture overview | +| 2020.01.13 | 01.00.03 | Addition of reference slicing architecture section | +| 2020.01.21 | 01.00.04 | Addition of A1/E2/O1/O2 sections and updates to reference slicing architecture section, updates to references, abbreviations | +| 2020.02.04 | 01.00.05 | Addition of generic slice deployment option diagram/section, 3GPP-ETSI implementation, updated reference slicing architecture, | +| 2020.02.10 | 01.00.06 | Updated reference slicing architecture based on feedback, added notes on 3GPP 28.526 VNF/PNF handling | +| 2020.03.01 | 01.00.07 | Updated architecture with SMO alignment discussion, ordered references, fixed table of contents issues, editorial updates | +| 2020.03.11 | 01.00.08 | Updates to various sections based on review feedback during WG1 approval process | +| 2020.03.11 | 01.00 | Final version 01.00 | +| 2020.04.20 | 02.00.01 | Initial version of v2.0

Document version number update to v02.00.01 | +| 2020.06.26 | 02.00.02 | Addition of slice subnet management and provisioning use cases and requirements:

- NET.AO-2020.06.25-WG1-CR-0100-SliceManagementUseCases | +| 2020.06.27 | 02.00.03 | Addition of multi-vendor slices use case:

- KDDI.AO-2020.06.26-WG1-CR-0100-MultiVendorSlice-UC-CR-Summary | +| 2020.06.27 | 02.00.04 | Addition of NSSI resource allocation optimization use case:

- INT.AO-2020.06.25-WG1-CR-0100-NSSI-Rsrc-Opt-UC-CR-Summary | +| 2020.06.28 | 02.00.05 | Editorial changes, corrections | +| 2020.07.13 | 02.00.06 | Updates per WG1 review process:

- Correct reference numbers in section 3.1
- Correct minor mistakes/editorial updates
- Add handling of TN segment to modification and feasibility check use cases
- Clarification updates to Requirements 13, 15 | +| 2020.07.16 | 02.00.07 | Getting the version ready to be published externally (removal of track changes/comments) | +| 2020.07.16 | 02.00 | Final version 02.00 | +| 2020.10.22 | 03.00.01 | Initial version of v3.0

Document version number update to v03.00.01 | +| 2020.11.02 | 03.00.02 | Addition of CR: | + +| | | | +|------------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------| +| | | - NET-2020.10.27-WG1-CR-0001-O-RAN-Slicing-Architecture-v02
Editorial updates | +| 2020.11.13 | 03.00.03 | Updates based on WG1 review comments | +| 2020.11.13 | 03.00 | Final version 03.00 | +| 2021.03.02 | 04.00.01 | Initial version of v4.0
Document version number update to v04.00.01 | +| 2021.03.06 | 04.00.02 | Addition of CR:
- JNPR-2021.03.01-WG1-CR-0001-Slicing_Transport_Networks_Section-v01 | +| 2021.03.06 | 04.00.03 | Addition of CR:
- JNPR-2021.03.01-WG1-CR-0002-O-RAN-Slicing-ONSSI-Allocation-v01 | +| 2021.03.06 | 04.00.04 | Addition of CR:
- JNPR-2021.03.01-WG1-CR-0003-O-RAN-Slicing-ONSSI-Deallocation-v01 | +| 2021.03.13 | 04.00 | Final version 04.00 | +| 2021.07.10 | 05.00.01 | Initial version of v5.0
Document version number update to v05.00.01 | +| 2021.07.11 | 05.00.02 | Addition of CR:
- RBBN.AO-2021.06.25-WG1-CR-0001-Annex-TN-Slicing-v06 | +| 2021.07.12 | 05.00.03 | Addition of CR:
- JNPR-2021.05.31-WG1-CR-0004-O-RAN-Slicing-ONSSI-Modification-v02 | +| 2021.07.19 | 05.00 | Final version 05.00 | +| 2021.11.11 | 06.00.01 | Initial version of v6.0
Document version number update to v06.00.01 | +| 2021.11.12 | 06.00.02 | Addition of relevant parts of CR:
- NC.AO-2021.07.20-WG1-CR-0001-NSSIResourceAllocationWithQuota-v04 | +| 2021.11.12 | 06.00.03 | Correction of terminology used in NSSI optimization use case | +| 2021.11.14 | 06.00.04 | Addition of CR:
- NOK.AO.2021.10.13-WG1-NetworkSlicingArchitecture-TerminologyAwareness
Editorial updates to Appendix C | +| 2021.11.14 | 06.00.05 | Clean version for WG1 approval | +| 2021.11.23 | 06.00.06 | Updates to address WG1 review comments | +| 2021.11.23 | 06.00 | Final version 06.00 | +| 2022.03.26 | 06.00.07 | Adopted new spec revision numbering per O-RAN Work Procedures
Initial version towards v07.00, starting with v06.00.07 per new revision numbering | +| 2022.03.26 | 06.00.08 | Addition of CR:
- JNPR-2022.03.14-WG1-CR-0005-O-RAN-Slicing-ONSSI-Provisioning-WG6Details | + +| | | | +|------------|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.03.26 | 06.00.09 | Addition of CR:

- RBBN.AO-2022.03.02-WG1-CR-0001-Annex-TN-Slicing-v02 | +| 2022.03.26 | 06.00.10 | Changes accepted from v06.00.09

Baseline for WG1 approval | +| 2022.04.04 | 07.00 | Final version 07.00 | +| 2022.07.24 | 07.00.01 | Initial version towards v08.00, starting with v07.00.01 per O-RAN specification revision numbering process | +| 2022.07.25 | 07.00.02 | Addition of CR:

- NC.AO-2022.05.02-WG1-NC-0004-MultiOperatorRANSliceSubnetAnnexure-v02

Editorial updates and corrections | +| 2022.07.25 | 07.00.03 | Update of the document to comply with the new O-RAN Technical Spec template | +| 2022.07.25 | 07.00.04 | All changes accepted, clean version for WG1 approval | +| 2022.08.01 | 08.00 | Final version 08.00 | +| 2022.11.10 | 08.00.01 | Initial version towards v09.00, starting with v08.00.01 per O-RAN specification revision numbering process

Addition of CR:

- NC.AO-2022.05.02-WG1-NC-0004-MultiOperatorSliceAnnexure-v04 | +| 2022.11.10 | 08.00.02 | Addition of CR:

- NC.AO-2022.05.02-WG1-NC-0005-MultiOperatorSliceAnnexure-v04 | +| 2022.11.10 | 08.00.03 | Addition of CR:

- NOK.AO-2022.10.14-WG1-CR-0000-NetworkSlicing-Editorials-v02 | +| 2022.11.13 | 08.00.04 | Added O-RAN Release "R003" to document name, updated copyright to 2023 as the document will be published externally in 2023.

All changes accepted, clean version for WG1 approval | +| 2022.11.18 | 09.00 | Final version 09.00 | +| 2023.03.14 | 09.00.01 | Initial version towards v10.00, starting with v09.00.01 per O-RAN specification revision numbering process.

Update of the spec to latest O-RAN TS template except for splitting the references to formative and informative. This split is planned to be made in next release of the document. | +| 2023.03.14 | 09.00.02 | Addition of CR:

- NC.AO-2022.12.05-WG1-CR-0007-ExtMnSConsumerRegistration&AA-v02 | +| 2023.03.14 | 09.00.03 | Addition of CR:

- JNPR-2023.03.14-WG1-CR-0007-O-RAN-Slicing-Arch-Annex_Editorials-v01 | +| 2023.03.14 | 09.00.04 | All changes accepted, clean version for WG1 approval | +| 2023.03.24 | 09.00.05 | WG1 review comments are addressed, and approval is completed. Ready for TSC approval and publication. | +| 2023.03.24 | 10.00 | Final version 10.00 | + +| | | | +|------------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.04.27 | 10.00.01 | Initial version towards v11.00, starting with v10.00.01 per O-RAN specification revision numbering process.

Addition of CR:

- JNPR-2023.04.10-WG1-CR-0008-O-RAN-Slicing-Arch-ODR-References-Section-v02 | +| 2023.04.25 | 10.00.02 | Addition of CR:

- JNPR-2023.04.25-WG1-CR-0009-O-RAN-Slicing-Arch-ODR-References-Update-v01 | +| 2023.05.09 | 10.00.03 | Addition of CR:

- JNPR-2023.05.09-WG1-CR-0014-O-RAN-Slicing-Arch-ODR-References-Correction-v01 | +| 2023.05.09 | 10.00.04 | Addition of CR:

- JNPR-2023.05.09-WG1-CR-0015-O-RAN-Slicing-Arch-ODR-References-Section-v01 | +| 2023.05.09 | 10.00.05 | Addition of CR:

- JNPR-2023.05.09-WG1-CR-0016-O-RAN-Slicing-Arch-ODR-References-Update-v01 | +| 2023.05.11 | 10.00.06 | Addition of CR:

- JNPR-2023.05.09-WG1-CR-0017-O-RAN-Slicing-Arch-ODR-References-Wording-v02 | +| 2023.05.23 | 10.00.07 | Addition of CR:

- JNPR-2023.05.23-WG1-CR-0024-O-RAN-Slicing-Arch-ODR-Figures-References_and_Wording-v01 | +| 2023.06.06 | 10.00.08 | Addition of CR:

- JNPR-2023.06.06-WG1-CR-0027-O-RAN-Slicing-Arch-ODR-Tables-References_Headings_Corrections-v01 | +| 2023.06.06 | 10.00.09 | Addition of CR:

- JNPR-2023.06.06-WG1-CR-0028-O-RAN-Slicing-Arch-ODR-Notes-v02 | +| 2023.06.15 | 10.00.10 | Addition of CR:

- JNPR-2023.06.15-WG1-CR-0034-O-RAN-Slicing-Arch-ODR-Paragraphs-Referencing-v01 | +| 2023.07.03 | 10.00.11 | Addition of CR:

- JNPR-2023.07.03-WG1-CR-0039-O-RAN-Slicing-Arch-ODR-Modal-Verbs_Shall_Shall_not_Should_Should_not_Must_Must_not-v01 | +| 2023.07.03 | 10.00.12 | Addition of CR:

- JNPR-2023.07.03-WG1-CR-0040-O-RAN-Slicing-Arch-ODR-Modal-Verbs_Can_Cannot_May_Need_not-v01 | +| 2023.07.20 | 10.00.13 | Addition of CR:

- NEC.AO-2023.06.19-WG1-CR-0009-eMnS-Publish-and-Discovery-v02 | +| 2023.07.20 | 10.00.14 | - Update of the spec to latest O-RAN TS template

- Correction of font types and spacing across the spec per ODR requirements

- Editorial corrections | +| 2023.07.20 | 10.00.15 | Clean version for WG1 approval | + +| | | | +|------------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.07.27 | 10.00.16 | WG1 review comments are addressed, and approval is completed. | +| 2023.07.27 | 10.00.17 | All changes accepted, clean version. | +| 2023.07.27 | 11.00 | Final version 11.00 | +| 2023.11.01 | 11.00.01 | Initial version towards v12.00, starting with v11.00.01 per O-RAN specification revision numbering process.

Addition of CR:

- JNPR-2023.11.01-WG1-CR-0042-O-RAN-Slicing-Arch-ODR-FFS-Concepts-v01 | +| 2023.11.01 | 11.00.02 | Addition of CR:

- JNPR-2023.11.01-WG1-CR-0043-O-RAN-Slicing-Arch-ODR-Terms-Abbreviations-Corrections-v01 | +| 2023.11.03 | 11.00.03 | Addition of CR:

- JNPR-2023.11.03-WG1-CR-0044-O-RAN-Slicing-Arch-ODR-Editorial-Modifications-v02 | +| 2023.11.07 | 11.00.04 | Addition of CR:

- JNPR-2023.09.08-WG1-CR-0041-O-RAN-Slicing-Arch-Review-Comments-v01 | +| 2023.11.08 | 11.00.05 | Addition of CR:

- JNPR-2023.11.07-WG1-CR-0045-O-RAN-Slicing-Arch-ODR-Modal-Verbs-v03 | +| 2023.11.08 | 11.00.06 | Clean version for WG1 approval | +| 2023.11.16 | 11.00.07 | WG1 review comments are addressed, and approval is completed. | +| 2023.11.16 | 11.00.08 | All changes accepted, clean version. | +| 2023.11.16 | 12.00 | Final version 12.00 | +| 2023.12.07 | 12.00.01 | Initial version towards v13.00, starting with v12.00.01 per O-RAN specification revision numbering process.

Addition of CR:

- JNPR-2023.12.05-WG1-CR-0048-O-RAN-Slicing-Arch-ODR-Clauses-Text_Modifications-Editorial_Corrections-v03 | +| 2024.01.29 | 12.00.02 | Addition of CR:

- JNPR-2023.12.27-WG1-CR-0049-O-RAN-Slicing-Arch-ODR-Capital_Letters-Editorial_Changes-v01 | +| 2024.03.22 | 12.00.03 | Addition of CR:

- NOK.AO-2024.03.12-WG1-CR-0007-ReservationFeasibilityCheck_v01.01 | +| 2024.03.22 | 12.00.04 | Clean version for WG1 approval | +| 2024.03.31 | 12.00.05 | WG1 review comments are addressed, and approval is completed. | +| 2024.03.31 | 12.00.06 | All changes accepted, clean version. | +| 2024.03.31 | 13.00 | Final version 13.00 | +| 2024.06.25 | 13.00.01 | Initial version towards v14.00, starting with v13.00.01 per O-RAN specification revision numbering process.

Addition of CR: | + +| | | | +|------------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | - NOK.AO-2024.05.02-WG1NSTG-CR0009-ProcedureStepLeaders_v02.00 | +| 2024.07.05 | 13.00.02 | Clean version for WG1 approval | +| 2024.07.18 | 13.00.03 | WG1 review comments are addressed, and approval is completed. | +| 2024.07.18 | 13.00.04 | All changes accepted, clean version. | +| 2024.07.18 | 13.01 | Final version 13.01 | +| 2024.10.01 | 13.01.01 | Initial version towards next release, starting with v13.01.01 per O-RAN specification revision numbering process.

Addition of CRs:

  • - JNPR-2024.09.17-WG1-CR-0062-O-RAN-Slicing-Arch-ETSI_PAS_Comments_for_NSI_and_NSSI_Terms-v01
  • - JNPR-2024.09.17-WG1-CR-0063-O-RAN-Slicing-Arch-ETSI_PAS_Comments_for_RAN_Slice_Subnet_and_NSSI-v01
  • - JNPR-2024.09.23-WG1-CR-0064-O-RAN-Slicing-Arch-ETSI_PAS_Comments_RAN_Slice_Subnet_entire_spec-v01
  • - JNPR-2024.09.23-WG1-CR-0065-O-RAN-Slicing-Arch-ETSI_PAS_Comments_for_NSSI_to_the_entire_spec-v01
| +| 2024.11.04 | 13.01.02 | Addition of CRs:

  • - JNPR-2024.10.22-WG1-CR-0071-O-RAN-Slicing-Arch-ETSI_PAS_Comments-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0072-O-RAN-Slicing-Arch-Rel-18-Upgrade-28.530-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0073-O-RAN-Slicing-Arch-Rel-18-Upgrade-23.003-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0074-O-RAN-Slicing-Arch-Rel-18-Upgrade-22.261-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0075-O-RAN-Slicing-Arch-Rel-18-Upgrade-28.526-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0076-O-RAN-Slicing-Arch-Rel-18-Upgrade-28.532-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0077-O-RAN-Slicing-Arch-Rel-18-Upgrade-28.552-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0078-O-RAN-Slicing-Arch-Rel-18-Upgrade-ETSI-NFV-003-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0079-O-RAN-Slicing-Arch-Rel-18-Upgrade-28.801-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0080-O-RAN-Slicing-Arch-Rel-18-Upgrade-23.501-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0081-O-RAN-Slicing-Arch-Rel-18-Upgrade-38.300-v01
  • - JNPR.AO-2024.10.22-WG1-CR-0082-O-RAN-Slicing-Arch-Rel-18-Upgrade-28.541-v01
  • - NOK.AO-2024.06.12-WG1NSTG-CR0008-ReservationFeasibilityCheck_v01.01
| +| 2024.11.15 | 13.01.03 | Addition of CRs:

  • - JNPR.AO-2024.11.05-WG1-CR-0083-O-RAN-Slicing-Arch-Rel-18-Upgrade-32.300-v01
| + +| | | | +|------------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | |
  • - JNPR-2024.11.05-WG1-CR-0084-O-RAN-Slicing-Arch-Capitalization_Clauses_Titles-v01

Updated copyright statement on the cover page and footer to 2025

Editorial changes to align to O-RAN TS template v02.01

Added 3GPP Release 18 related text to Normative and Informative References clauses

Editorial updates

| +| 2024.11.21 | 13.01.04 | Clean version for WG1 approval | +| 2024.12.06 | 13.01.05 | WG1 review comments are addressed, and approval is completed. | +| 2024.12.06 | 13.01.06 | All changes accepted, clean version. | +| 2024.12.06 | 14.00 | Final version 14.00 | \ No newline at end of file diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/02377c601cba92e8bad617c718f91b13_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/02377c601cba92e8bad617c718f91b13_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e8b33d0a5ad796fdcb16a09250aede31f535d021 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/02377c601cba92e8bad617c718f91b13_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c330e0b113092f0ade308884a1670f6220b1ef768b05e9bd986c71267051687a +size 47892 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/0ecd0dd8bd3f423b855f4b5cbe175ad2_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/0ecd0dd8bd3f423b855f4b5cbe175ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..31988d7380adb2ad55874d3df68115a1a187ddc1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/0ecd0dd8bd3f423b855f4b5cbe175ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ba40b9eb6c5cec3a62ae4d5b3f4b2d4fac5b671a1fe9666a8d7f5fcd95cfc8ca +size 130866 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/1fd5bd1eb65f714d27c57dccebbd9034_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/1fd5bd1eb65f714d27c57dccebbd9034_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..36cb513d6173785fef2b9f23e99fb82be908796b --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/1fd5bd1eb65f714d27c57dccebbd9034_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e6c9ef54eb7d70cef5b132ff4670b443093b9b01f54591b2018999d368ea6d1 +size 38631 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/23123813b4d6708e8c018550c33af9a4_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/23123813b4d6708e8c018550c33af9a4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ac8190dbcb6ede73448ea4f79c2106032258bfc0 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/23123813b4d6708e8c018550c33af9a4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:16091f94de964f9e85e52e89f58b40cbf0ed6a4c65fb84ff700b0b5fba4d2b73 +size 63993 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/28be4653b90cccbe7ee396890e08cc80_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/28be4653b90cccbe7ee396890e08cc80_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dd3c98ad452691a2e32ef23b5c595554bf42e26b --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/28be4653b90cccbe7ee396890e08cc80_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a136b8823be61aae095ac842a5c100fc0c6750533187c5577d5a3180ada54841 +size 62028 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/38f727ca5c261d11a408497c67dfa164_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/38f727ca5c261d11a408497c67dfa164_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d36a825154ef7a85254d2cdbe11572141e1158d1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/38f727ca5c261d11a408497c67dfa164_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dc6207b5d8fac1576eaf6a89771276f68a8fe41364ba1f6011f8ddb63fcb487c +size 51924 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/3aa8d8f171a935e0864621c9c8494383_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/3aa8d8f171a935e0864621c9c8494383_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ab13c1c58d93757e81e8e3c553cfe3c29a3bbb5e --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/3aa8d8f171a935e0864621c9c8494383_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a04a9a31c7783676db42dd8a4810a2b29d180fcbb1c40d4461aded09fcc944df +size 40844 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/3ee5821edf142c50f59bd5f56b68ad83_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/3ee5821edf142c50f59bd5f56b68ad83_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6dc135f1e3f7fa68417d97102ca88356e8056ffc --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/3ee5821edf142c50f59bd5f56b68ad83_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fc0bac0a64a51d3833f77ad716a5e7b1a61d9b2f48034cc12f29ecf5b558bedd +size 43674 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4036ae059aedff1b609283770fd4cbab_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4036ae059aedff1b609283770fd4cbab_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c2ed43f828931ce8d62106978fc7d85aba0cecfe --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4036ae059aedff1b609283770fd4cbab_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:51ac2f9b317fe55491bef8df22d451cf8cf2a5bc23888e5c33889c084ad12968 +size 60571 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/449108cc71696dd2eb0b96bbe0da6ea7_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/449108cc71696dd2eb0b96bbe0da6ea7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1e59490709c98f674041b63401f3e8a1e5f86995 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/449108cc71696dd2eb0b96bbe0da6ea7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0b88cd8ee3e9d5e53d93484d3f333dc3a0abb9b84429075877655f29022e938f +size 73557 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4e57f2b463ea0be87bacd899449acb39_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4e57f2b463ea0be87bacd899449acb39_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ad42a97bbd49f819975276d8a5b76d85834dff05 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4e57f2b463ea0be87bacd899449acb39_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6e8dcc42f6bec33928b8aee8a77276e7d28e3a6ed9e14eefba7512957ac51cf6 +size 184250 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4eb3b972409332eeb79e6146cc43f3f2_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4eb3b972409332eeb79e6146cc43f3f2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5df43b4c80f8606e8d39e619c8a3eac493a6b676 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4eb3b972409332eeb79e6146cc43f3f2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7f4c1672f8a090ce02d01c54d6f6eec4e946402afc6ceaf05738b54cf392eef7 +size 243400 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4f3dadd1e46ac63d5a74c959a0d79ecc_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4f3dadd1e46ac63d5a74c959a0d79ecc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..66b3f843667148187590986f5e5df668b04dd2bc --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/4f3dadd1e46ac63d5a74c959a0d79ecc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4286e45c9803e1e274c1292ab6269f92797b893047f8f20b974a03aaa20fff85 +size 41389 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/64ecef7181dd25b626bf999b65a81d22_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/64ecef7181dd25b626bf999b65a81d22_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9f3cc8d3d19dd0b883ccf87ab5747d8be2af7340 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/64ecef7181dd25b626bf999b65a81d22_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b0211c5ed32df330714509b9d78c712886de320657d231be451bffb4fdeaf006 +size 122038 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/65c52ea6fe23749d831db7eb309cd36f_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/65c52ea6fe23749d831db7eb309cd36f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b07e9b4020b0e93469605d7b1cfd476f3722150a --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/65c52ea6fe23749d831db7eb309cd36f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:31f6b9fb8500b2b223b6ff730cb7eb9cff24334b880aec7e5d80d0bba10b7a8b +size 143283 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/6862f166f54224feff37422470ad1559_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/6862f166f54224feff37422470ad1559_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..640c83e514744a2aa48d2ef20a88aa30612eaa7b --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/6862f166f54224feff37422470ad1559_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:44ce1a2d05485015d5b0e5550e64a269ec1eab86bcc3e5e59e2ad638ebb4b705 +size 39385 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/73b0081bfd137e23536e275c5cb3dbd3_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/73b0081bfd137e23536e275c5cb3dbd3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7c912ceec626270201cb0cb35bc4e29f279cf698 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/73b0081bfd137e23536e275c5cb3dbd3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bb633e334033e7e4b5b1ec3235cf15896d7daf77267150e634daf73acb2ed071 +size 173118 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/77559e17b597785019c144cedf4b683f_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/77559e17b597785019c144cedf4b683f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dea5c1096715d190dcdad6722b1a53451985ba00 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/77559e17b597785019c144cedf4b683f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9c5c7f89fe0311b57d4a8982eb723f4c8af4680a13bd29b4c8864797584dfbd4 +size 37716 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/7948f7f3ec3ea417ce28ab875405506c_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/7948f7f3ec3ea417ce28ab875405506c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3c9c07a2e0a3aa61da1cf249d8f689d6455f8ed3 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/7948f7f3ec3ea417ce28ab875405506c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fe586d4e6dcc8b75089c7b336317c9ed6a3e28081d8c0e869c70f10f1d843129 +size 4522 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/8fe1529bf1222170bff630d1cc2ca08f_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/8fe1529bf1222170bff630d1cc2ca08f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0525031e22a1318a410a6aef1828ebc482f512be --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/8fe1529bf1222170bff630d1cc2ca08f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b3aafae981a35fcb259dc9931da1804996c6adf2aaef8d1be8d6c36258e5bdb3 +size 40526 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/939559840b1f76a24f799c140944fe77_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/939559840b1f76a24f799c140944fe77_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8c41e060f72e0778d8625aa82a38812fb1da9a78 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/939559840b1f76a24f799c140944fe77_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cbe33dc8c7388730662572d4dc5ba78888b6c8d5b83fcbe0d9fddda3f6d065c7 +size 11824 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/93abff78fac32820fc24080a70737823_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/93abff78fac32820fc24080a70737823_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..559dfc4aa7b0714e2ee262b4b61c64d2641ca75a --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/93abff78fac32820fc24080a70737823_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:116b7aea30e145c5e53f75b4a4a420f4746276f997a4cf23af43ad68dab93fb2 +size 34106 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/9ae3cc9d2aad88294860939e4259f01d_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/9ae3cc9d2aad88294860939e4259f01d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e37e6c8cb0bf5db4bb373af2680c33166ea7cd5c --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/9ae3cc9d2aad88294860939e4259f01d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:362f42b8c2283ae84a67327a6ea0e6e17581143314a9df2709838f6b549a739d +size 71986 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/a08a226499932f48cacdcd456f8499b8_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/a08a226499932f48cacdcd456f8499b8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ecbaff41c125cadf815aa48415aee1ce4f97d8a2 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/a08a226499932f48cacdcd456f8499b8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:de06bef48f0de5d2ec6d017b1fdc69b4010127c210d6aab5ac72986924c2fab8 +size 64703 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/a64ca3bd463359470a1aa7cc9c043390_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/a64ca3bd463359470a1aa7cc9c043390_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9723f4eef3a6aaab280ea872e5c83766ce7d51a1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/a64ca3bd463359470a1aa7cc9c043390_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:075caa293f463846db2d8488e5c8feda467b40ad7097accf99a233e21fd3b954 +size 190914 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/aa53fa174f7563d96f87b831521ae145_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/aa53fa174f7563d96f87b831521ae145_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6ba8e1a06e79458f2f581ad53507cb2f10a180a1 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/aa53fa174f7563d96f87b831521ae145_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c1ad29367f53fd6dfdb9ccf5d2daf84bdb7c5163aff32bb67486e70d5365e956 +size 4558 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/ac695a400dbb79cbe179ca0199991979_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/ac695a400dbb79cbe179ca0199991979_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..97490db4dad34d2185188b5a69a357a30bd573bf --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/ac695a400dbb79cbe179ca0199991979_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c49e5dc182ea90718bc3f5ae8c510039f6641fc69ed9a3e96f7b6f9336765dbf +size 4602 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/b9d9a1e5ed688d0594b52d21a62c8168_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/b9d9a1e5ed688d0594b52d21a62c8168_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..51a915d5aa172edb1be2b3dbf077a7ad7afe38d5 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/b9d9a1e5ed688d0594b52d21a62c8168_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:eba425bdbbe932916d83a62a1c3d0a593783dcf8d20592e0560b432ec33ee69f +size 122542 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/bb10c312303fbe213c5faa8f9ced1f6e_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/bb10c312303fbe213c5faa8f9ced1f6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f11ceaf023e2442b086dc4e85b1ce72ecaf72f34 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/bb10c312303fbe213c5faa8f9ced1f6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d1f183753a9a8ecdcf6999c8a3b800397046188b9d10fe27797d2039f630ea9b +size 39067 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7575c364a05dd515d7cf096c30ffc26f8ab2631 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b321cfff0a169d11fa6daa2e14ee4667e12bcfeff34e35ee9dd80b810a6385a6 +size 4491 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/c1204951d9b0786ba1d406ae059d5f3a_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/c1204951d9b0786ba1d406ae059d5f3a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..974403faad5529b1aa7ad562d07ce4b303efcd47 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/c1204951d9b0786ba1d406ae059d5f3a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c0e30dfba734884a877dea26e7be7462ad778a76bd36d9dd73cb27ae2a81779a +size 45845 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/c3a87de72245cd402af8fb607d1cf231_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/c3a87de72245cd402af8fb607d1cf231_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dc7e3820de37afa0f626c886e2bc9ee4ab746c94 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/c3a87de72245cd402af8fb607d1cf231_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a1c97be41489ed189593605dbd92b368e151852e6d1e55a1f1e809892f2c4d85 +size 42072 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/cb1c8b756a17151f5e2c60cf85a6a153_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/cb1c8b756a17151f5e2c60cf85a6a153_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..416bf46c111c2011b8849c9be731d2392514cc09 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/cb1c8b756a17151f5e2c60cf85a6a153_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:660cc0da998019bc2e006a006911bf6468a6a83456d120663a8dcacd3cef6ccb +size 39225 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d465a67b3dbeeda30a0330085be7809f_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d465a67b3dbeeda30a0330085be7809f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..90113529bff0a612fe07f421594d9f77302ef59c --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d465a67b3dbeeda30a0330085be7809f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ae93037dde4f8a84d8c9a79fd9e69bd6476a6402d5be1d1ef5c64ae28de1587 +size 17795 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d74fddb8ff3a4f59b2366861b52257ab_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d74fddb8ff3a4f59b2366861b52257ab_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b1f14a1364d1d81067adefab0a1ab530208fd4d6 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d74fddb8ff3a4f59b2366861b52257ab_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce9adb1d475f4c2e510edf17173e34ff2608baf7306d1cb3982be73effcb233b +size 27842 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d7b32db967fa51a1a6a61e40a676c5a2_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d7b32db967fa51a1a6a61e40a676c5a2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ca2b8366058c73be47672dc1679e955a64c48e1e --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d7b32db967fa51a1a6a61e40a676c5a2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7719d50c31fa03ffd5e0df06d65e799fad5c1017a12dd6644d6a53f6e3dac8e6 +size 23522 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d9952dfd89f7cf5167c12328516d9080_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d9952dfd89f7cf5167c12328516d9080_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..966e9ad2545fc255daedd7b91093a88b9b5d2309 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/d9952dfd89f7cf5167c12328516d9080_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a0a1eafce7704c252b3e9b49f5cb963abce846e1253da8b5821cb4f24449596f +size 29905 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/decab4156c1e7b9b4ffc0393e70be588_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/decab4156c1e7b9b4ffc0393e70be588_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6d1c7be61ebb46ef6f651b7ef3325aa79cf8cbfe --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/decab4156c1e7b9b4ffc0393e70be588_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:304c881b6c3bda466ef513fbaa47220be0a62b880f4ae199fa5308cb1dcbf540 +size 67668 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/ff56d24cdf3b4a15fa448cc23bc9fe4e_img.jpg b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/ff56d24cdf3b4a15fa448cc23bc9fe4e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..231c1310940ff9bf279661b12031bf3b1d0880ae --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/ff56d24cdf3b4a15fa448cc23bc9fe4e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c79cf844b3662f7777dbc78e870b73be4556a85a9d3f2caa3afea2a3c8f29c63 +size 48035 diff --git a/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/raw.md b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..ba663a85d44cecb0dfd77e633e5aec395d231489 --- /dev/null +++ b/marked/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00/raw.md @@ -0,0 +1,3910 @@ + + +# **O-RAN Working Group 1 Massive MIMO Use Cases Technical Report** --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Working Group 1 Massive MIMO Use Cases Technical Report** --- + +Copyright © 2022 by O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in the Annex *ZZZ* of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +1 + +# Revision History + +| Date | Revision | Author | Description | +|------------|----------|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2021.06.14 | 01.00.00 | Nokia, Keysight | Document skeleton | +| 2021.07.09 | 01.00.01 | Nokia, Keysight | Update the ToC | +| 2021.10.06 | 01.00.02 | Editors | Added approved CRs | +| 2021.10.08 | 01.00.03 | Editors | Removed change marking | +| 2021.11.02 | 01.00.04 | Editors | Added additional approved CRs | +| 2021.11.18 | 01.00.05 | Editors | Added additional approved CRs | +| 2021.12.01 | 01.00.06 | Editors | Added additional approved CRs | +| 2021.12.03 | 01.00.07 | Editors | Added additional approved CRs | +| 2021.12.08 | 01.00.08 | Editors | Added additional approved CRs | +| 2021.12.12 | 01.00.09 | Editors | Added additional approved CRs | +| 2021.12.14 | 01.00.10 | Editors | Added 1 missing CR, clean-up formatting, fixed font issues, removed comments, fixed minor grammaticals | +| 2021.12.15 | 01.00.11 | Editors | Added additional approved CRs, and agreed-upon changes during call on 12/15 | +| 2022.03.24 | 01.00.12 | Editors | Changed title/header, corrected formatting and typos | +| 2022.03.24 | 01.00.13 | Editors | Changed title/header, corrected formatting and typos | +| 2022.03.29 | 00.00.14 | Editors | Fix title page, clean version for WG1 approval | +| 2022.04.04 | 01.00 | Editors | Spec renamed to v01.00 for publication | +| 2022.05.12 | 01.00 | Editors | Correction of one reference in Section 3.2.2.1.1 | +| 2022.06.01 | 01.00 | Editors | Editorial improvements: Included line separations and page breaks to avoid e.g. table splits, completed table and figure captions, removed few section numbering higher than five digits and included two four digits sub-sections to enable automatic figure and table caption numbering, copy & paste of one paragraph from chapter 7 into section 3.1 to fill empty space, corrected cross-references and minor editorials | +| | | | | +| | | | | +| | | | | +| | | | | +| | | | | +| | | | | +| | | | | + +2 + +# Contents + +| | | | +|----|------------------------------------------------------------------------------------------------------------|----| +| 1 | Revision History ..... | 2 | +| 3 | 1 Introduction ..... | 6 | +| 4 | 1.1 Scope ..... | 6 | +| 5 | 1.2 References ..... | 6 | +| 6 | 1.3 Definitions and Abbreviations ..... | 7 | +| 7 | 1.3.1 Definitions ..... | 7 | +| 8 | 1.3.2 Abbreviations ..... | 8 | +| 9 | 2 Objectives and Requirements ..... | 9 | +| 10 | 2.1 Objectives ..... | 9 | +| 11 | 2.2 Requirements ..... | 9 | +| 12 | 3 GoB / L3 Mobility ..... | 11 | +| 13 | 3.1 Overview ..... | 11 | +| 14 | 3.2 Solution 1: Grid-of-Beams Beamforming (GoB BF) Optimization ..... | 11 | +| 15 | 3.2.1 Problem Statement, Solution and Value Proposition ..... | 11 | +| 16 | 3.2.2 Architecture/Deployment Options ..... | 12 | +| 17 | 3.2.3 Impact Analysis on O-RAN Working Groups ..... | 17 | +| 18 | 3.2.4 Relation and Impact on 3GPP Specifications ..... | 19 | +| 19 | 3.2.5 Feasibility and Gain/Complexity Analysis ..... | 20 | +| 20 | 3.3 Solution 2: Beam-based Mobility Robustness Optimization (bMRO) ..... | 22 | +| 21 | 3.3.1 Problem Statement, Solution, and Value Proposition ..... | 22 | +| 22 | 3.3.2 Architecture/Deployment Options ..... | 22 | +| 23 | 3.3.3 Impact Analysis on O-RAN Working Groups ..... | 26 | +| 24 | 3.3.4 Relation and Impact on 3GPP Specification ..... | 28 | +| 25 | 3.3.5 Feasibility and Gain/Complexity Analysis ..... | 30 | +| 26 | 3.4 Solution 3: AI/ML Based Initial Access (SS Burst Set), CSI-RS and DMRS Configuration Optimization .... | 33 | +| 27 | 3.4.1 Problem Statement and Value Proposition ..... | 33 | +| 28 | 3.4.2 Architecture/Deployment Options ..... | 34 | +| 29 | 3.4.3 Feasibility and Gain/Complexity Analysis ..... | 54 | +| 30 | 4 L1 / L2 Beam Management ..... | 64 | +| 31 | 4.1 Overview ..... | 64 | + +| | | | | +|----|-------|--------------------------------------------------------------------------------------|-----| +| 1 | 4.2 | Solution 1: AI/ML-assisted Beam Selection Optimization ..... | 64 | +| 2 | 4.2.1 | Problem Statement and Value Proposition ..... | 64 | +| 3 | 4.2.2 | Architecture/Deployment Options ..... | 65 | +| 4 | 4.2.3 | Impact Analysis on O-RAN Working Groups ..... | 73 | +| 5 | 4.2.4 | Relation and Impact on 3GPP Specification ..... | 74 | +| 6 | 4.2.5 | Feasibility and Gain/Complexity Analysis ..... | 74 | +| 7 | 5 | Non-GoB Beamforming ..... | 77 | +| 8 | 5.1 | Overview ..... | 77 | +| 9 | 5.2 | Solution 1: AI/ML-assisted non-GoB Optimization ..... | 77 | +| 10 | 5.2.1 | Problem Statement and Value Proposition ..... | 77 | +| 11 | 5.2.2 | Architecture/Deployment Options ..... | 78 | +| 12 | 5.2.3 | Impact Analysis on O-RAN Working Groups ..... | 86 | +| 13 | 5.2.4 | Relation and Impact on 3GPP Specification ..... | 87 | +| 14 | 5.2.5 | Feasibility and Gain/Complexity Analysis ..... | 87 | +| 15 | 6 | MIMO DL Tx Power Optimization, MU-MIMO Pairing and MIMO mode selection ..... | 91 | +| 16 | 6.1 | Overview ..... | 91 | +| 17 | 6.2 | MIMO optimization use-cases ..... | 91 | +| 18 | 6.2.1 | Solution 1: Downlink Transmit power optimization ..... | 91 | +| 19 | 6.2.2 | Solution 2: MU-MIMO Pairing Enhancement (User Separability or Pairing Control) ..... | 98 | +| 20 | 6.2.3 | Solution 3: MIMO mode selection (Mu-MIMO vs Su-MIMO selection optimization) ..... | 112 | +| 21 | 7 | Comparison and Conclusions ..... | 122 | +| 22 | 7.1 | Summary of Evaluation ..... | 124 | +| 23 | 7.2 | Impact on standardization ..... | 125 | +| 24 | 7.3 | Synergies among new measurements (definition and/or reporting) ..... | 126 | +| 25 | | Annex A Input and output data and its relation to 3GPP specification ..... | 127 | +| 26 | | Annex ZZZ: O-RAN Adopter License Agreement ..... | 129 | +| 27 | | Section 1: DEFINITIONS ..... | 129 | +| 28 | | Section 2: COPYRIGHT LICENSE ..... | 129 | +| 29 | | Section 3: FRAND LICENSE ..... | 130 | +| 30 | | Section 4: TERM AND TERMINATION ..... | 130 | +| 31 | | Section 5: CONFIDENTIALITY ..... | 131 | +| 32 | | Section 6: INDEMNIFICATION ..... | 131 | + +| | | | +|---|--------------------------------------------------------|-----| +| 1 | Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 131 | +| 2 | Section 8: ASSIGNMENT ..... | 131 | +| 3 | Section 9: THIRD-PARTY BENEFICIARY RIGHTS ..... | 132 | +| 4 | Section 10: BINDING ON AFFILIATES ..... | 132 | +| 5 | Section 11: GENERAL..... | 132 | +| 6 | | | +| 7 | | | + +# 1 Introduction + +## 1.1 Scope + +This Technical Report has been produced by the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Release xx.yy.zz + +where: + +xx the first two-digit value is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document shall have xx=01). + +yy the second two-digit value is incremented when editorial only changes have been incorporated in the document. + +zz the third two-digit value is included only in working versions of the document indicating incremental changes during the editing process; externally published documents never have this third two-digit value included. + +The present document provides a technical report on RIC-enabled massive MIMO use cases. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document *in the same* Release as the present document. + +[1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". + +[2] MU-MIMO and CSI Feedback Performance of NR/LTE, Bishwarup Mondal et al., 2019 53rd Annual Conference on Information Sciences and Systems (CISS), 20-22 March 2019 + +[3] E. Bjornson, J. Hoydis, and L. Sanguinetti, Massive MIMO Networks: Spectral, Hardware, and Energy Efficiency. Foundations and Trends in Signal Processing, vol. 11, no. 3-4, pp. 154-655, 2017 + +[4] T. Marzetta, E Larsson, H. Yang, and H. Ngo, Fundamentals of Massive MIMO, Cambridge University Press, 2016 + +[5] Physical Layer Measurements 3GPP TS 38.215 V16.4.0 (2020-12) + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in TR 21.905 [1]. + +**Non-RT RIC** (O-RAN non-real-time RAN Intelligent Controller): a logical function that enables non-real-time control and optimization of RAN elements and resources, AI/ML workflow including model training and updates, and policy-based guidance of applications/features in Near-RT RIC. + +**Near-RT RIC** (O-RAN near-real-time RAN Intelligent Controller): a logical function that enables near-real-time control and optimization of RAN elements and resources via fine-grained (e.g. UE basis, Cell basis) data collection and actions over E2 interface. + +**O-CU**: O-RAN Central Unit: a logical node hosting RRC, SDAP and PDCP protocols. + +**O-CU-CP**: O-RAN Central Unit – Control Plane: a logical node hosting the RRC and the control plane part of the PDCP protocol. + +**O-CU-UP**: O-RAN Central Unit – User Plane: a logical node hosting the user plane part of the PDCP protocol and the SDAP protocol. + +**O-DU**: O-RAN Distributed Unit: a logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. + +**O-RU**: O-RAN Radio Unit: a logical node hosting Low-PHY layer and RF processing based on a lower layer functional split. This is similar to 3GPP's "TRP" or "RRH" but more specific in including the Low-PHY layer (FFT/iFFT, PRACH extraction). + +**O-eNB** (O-RAN eNB): an eNB or ng-eNB that supports E2 interface. + +**O1**: Interface between orchestration & management entities (Orchestration/NMS) and O-RAN managed elements, for operation and management, by which FCAPS management, Software management, File management and other similar functions shall be achieved. + +**SMO**: Service Management and Orchestration system. + +**A1**: Interface between Non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**E2**: Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. + +**E2 Node**: a logical node terminating E2 interface. In this version of the specification, ORAN nodes terminating E2 interface are: + +- for NR access: O-CU-CP, O-CU-UP, O-DU or any combination +- for E-UTRA access: O-eNB. + +**rApp**: An application designed to run on the Non-RT RIC. Such modular application leverages the functionality exposed by the Non-RT RIC to provide added value services relative to intelligent RAN optimization and operation + +**xApp**: An application designed to run on the Near-RT RIC. Such an application is likely to consist of one or more microservices and at the point of on-boarding will identify which data it consumes and which data it provides. The application is independent of the Near-RT RIC and may be provided by any third party. The E2 enables a direct association between the xApp and the RAN functionality. + +**O-Cloud**: O-Cloud is a cloud computing platform comprising a collection of physical infrastructure nodes that meet O-RAN requirements to host the relevant O-RAN functions (such as Near-RT RIC, O-CU-CP, O-CU-UP, and O-DU), the + +supporting software components (such as Operating System, Virtual Machine Monitor, Container Runtime, etc.) and the appropriate management and orchestration functions. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the following abbreviations apply. + +| | | +|-------------|-------------------------------------------| +| ML | Machine Learning | +| Non-RT RIC | Non-real-time RAN Intelligent Controller | +| Near-RT RIC | Near-real-time RAN Intelligent Controller | +| RAN | Radio Access Network | +| SMO | Service Management and Orchestration | + +# 2 Objectives and Requirements + +## 2.1 Objectives + +This Technical Report captures the outcome of the WG1 UCTG Massive MIMO pre-normative phase. The objectives of the pre-normative phase are as follows: + +- study requirements, key issues, proposed solutions, benefits of the massive MIMO enhancements, +- study potential impact and required enhancements to O-RAN interfaces E2, O1, A1, FH M-plane, FH CUS-Plane, R1 and Near-RT RIC API, +- study potential impact and required enhancements on data models of all O-RAN entities, +- identify the any possible impact on Non-RT RIC architecture, Near-RT RIC architecture and AI/ML workflow. + +The use cases studied in the Massive MIMO pre-normative phase include: + +- GoB optimization (SSB + CSI-RS based GoB), adaptive beam shaping and beam-based Mobility Robustness Optimization, +- Non-GoB optimization, +- L1/L2 beam management optimization, +- Additional use cases are DL and UL transmit power optimization, optimization of MU-MIMO co-scheduling through control of spatial separation thresholds, reference sequence optimization for minimization of contamination. + +The use cases are applicable to FR1 as well as FR2. Algorithms discussed and analysed as part of the Massive MIMO pre-normative phase will be examples only and will not be part of any specification as outcome of this pre-normative phase or subsequent work items. + +For each use case solution proposal, the detailed objectives are: + +- Review, evaluate applicability of, and select from existing deployment alternatives (Non-RT and/or Near-RT RIC) and AI/ML deployment scenarios and document respective findings. +- Review, evaluate, and select candidate(s) for normative standardization and document respective findings: + - Analyze and evaluate input/output parameters of the algorithm, the impact of the control loop delay on the network performance (e.g., due to dynamic channel conditions) as well as the signaling overhead over the relevant interface, e.g., O1, E2. + - Companies should provide simulation results for their mMIMO proposals to evaluate the performance benefits versus complexity taking into consideration E2 load and latency requirements for RIC and E2 node procedures. The availability of simulation results will not be used for gating in decision making. + - Study and review additional simulation methodologies required for evaluating RIC-enabled mMIMO optimization approaches. Review and, if possible, leverage existing methodologies already established in 3GPP. + +## 2.2 Requirements + +- mMIMO use cases should reuse the existing 3GPP measurements / measurement reporting for input data as well as the existing 3GPP configuration / provisioning management for the output data as much as possible. +- If new measurements or configuration parameters are essential to support new mMIMO use cases, then these should preferably be based on parameters / variables / definitions / procedures that are already used in the 3GPP / O-RAN specifications. + +- If new measurements or configuration parameters are essential to support new mMIMO use cases, the current standardization approach (specifying the new measurement in 3GPP specifications and referring to in in O-RAN specifications) should be prioritized over inventing new standardization approaches. + +# 3 GoB / L3 Mobility + +## 3.1 Overview + +Grid of Beam Optimization (GoB) provides an automated beam forming configuration tailored to the topology of the cell, the physical environment, as well as the distribution of users and traffic in a cell (e.g. wide beams might cover low-density areas while narrow beams might cover high-density areas). Beam-based Mobility Robustness Optimization (bMRO) is an autonomous self-optimizing algorithm that improves beam-based inter-cell mobility performance by applying beam-specific Cell Individual Offsets (CIO) on the handover triggers between neighbor cells, based on the analysis of beam-AI/ML assisted network-wide (multi-gNB/TRP) optimizations framework proactively and autonomously infers optimal configuration per gNB/TRP for SS Burst Set, DMRS and CSI-RS based on available measurements, observations, and PIs at different nodes of the 3GPP NR and/or O-RAN access and core network elements. + +## 3.2 Solution 1: Grid-of-Beams Beamforming (GoB BF) Optimization + +### 3.2.1 Problem Statement, Solution and Value Proposition + +Massive MIMO (mMIMO) is among the key methods to increase performance and QoS in 5G networks. Capacity enhancement is obtained by means of beamforming of the transmitted signals, and by spatially multiplexing data streams. Beamforming can increase the received signal power and simultaneously decrease the interference generated for other users, hence resulting in higher SINR and higher user throughputs. Grid-of-Beams (GoB) with the corresponding beam sweeping has been introduced to allow beamforming of the control channels used during initial access as well as for data transmission and reception, mainly for high frequency (but can be used also for the sub-6 GHz band) MIMO operation. The physical properties of the antenna array and its possible configurations characterize the span of the beams, namely the horizontal and vertical aperture in which beamforming is supported, and therefore the coverage area and the shape of the cell. mMIMO can be deployed in 5G macrocell clusters as well as in heterogeneous networks, where macro-cells and small cells co-exist and complement each other for better aggregated capacity and coverage. In order to obtain optimal beamforming and cell resources (Tx power, PRB) configuration, one will have to look at a multi-cell environment instead of a single cell. Moreover, different vendors may have different implementations in terms of the number of beams, the horizontal/vertical beam widths, azimuth and elevation range, to achieve the desired coverage. In a multi-node/multi-vendor scenario, centralized monitoring and control is required to offer optimal coverage, capacity and mobility performance as well as control over electromagnetic emissions in order to comply with regulatory requirements. + +The problem associated with traditional mMIMO BF is that its performance is highly dependent on the choice of the BF pattern. Manual configuration is usually based on the empirical knowledge and manual test results of the domain expert(s) and is performed in a semi-static way. That is, (near-)real time contextual, per-site information (such as cell geometry change, user/traffic distribution, mobility patterns, seasonalities etc.) is taken into account in a suboptimal and non-real time way. This may cause one or more of the following problems: + +1. High inter-cell interference. +2. Unbalanced traffic between neighboring cells. +3. Low performance at the cell edges or throughout the cell. +4. Poor handover performance. + +This solution proposes a framework that allows the operator to flexibly configure the mMIMO BF parameters in a cell or in a cluster of cells by means of policies and configuration assisted by machine learning (ML) techniques. The configuration optimization relies on contextual information and patterns such as the user distribution, traffic demand distribution, cell geometries, and mobility. + +### 3.2.2 Architecture/Deployment Options + +#### 3.2.2.1 Option 1: Non-RT RIC Deployment + +The Non-RT RIC hosts an rApp application whose task is to determine the suitable GoB configuration for a cell or a cluster of cells as a function of input metrics and of an operator objective. The underlying ML model is trained on historical data collected from a cell or a cluster of cells and its aim is to determine correlation patterns between mMIMO GoB configurations and performance metrics. The input data for GoB BF optimization training and inference can be comprised of antenna array parameters, UE mobility/spatial density data, (averaged) traffic density data, timing advance and Angle-of-Arrival measurements (for positioning estimation), power headroom (PH) reports, aggregated and/or pre-processed beam-based reference signal measurements (e.g. CSI reporting, covariance matrix), neighboring cells' beams/interference information, MDT measurement data, as well as performance measurements such as handover and beam failure statistics. The rApp knows O-RU specifics such as antenna array parameters, O-RU capabilities, beam file format (beamforming configuration update procedure) etc. + +The output of the inference is the optimized GoB BF configuration, that is, the number of beams and either i) the beam directions, horizontal & vertical beam widths, and power allocation of beams, or ii) the beam weights. + +Operator objectives regarding adaptive GoB may include desired coverage, defined in terms of the cell geometry (SSB beams), cell capacity requirements (CSI-RS beams), cell edge performance (e.g. minimum throughput per UE), minimum guaranteed throughput (independent of traffic density), weighted average RSRP requirements (e.g., the operator might wish to implement the strategy to cover low-density areas with wide beams and high-density areas with narrow beams), and desired fairness between cell edge and non-edge UEs. + +``` +@startuml +Box "Personnel" #lightblue + Actor "Operator" as RP +End box + +box "Service Management & \nOrchestration Framework" #gold + Participant "SMO & Non-RT RIC" as SMO + Participant "rApps" as rAPP +end box + +box "E2 Nodes" #lightpink + collections "O-CUs" as OCU + collections "O-DUs" as ODU +end box + +box "O-RUs" #lightpink + collections "O-RUs" as ORUs +end box + +box "External" #lightseagreen + Participant APP +end box +Autonumber + +activate RP +activate APP +activate SMO +activate rAPP +activate ODU +||| +group Data Collection +``` + +``` + +1 ODU -> SMO : <> Data Collection +2 OCU -> SMO : <> Data Collection +3 APP -> SMO : <> Data Collection +4 end +5 +6 group ML Training +7 SMO --> rAPP: Data Retrieval +8 rAPP --> rAPP: AI/ML model training +9 +10 end +11 +12 group ML Inference +13 alt +14 RP --> SMO: Optimization Trigger/Target +15 else +16 SMO --> SMO: Performance Degradation +17 end +18 SMO -> rAPP: <> Update Model Request +19 SMO -> rAPP: <> Data Retrieval +20 rAPP --> rAPP: AI/ML model inference +21 rAPP -> SMO: <> Optimal mMIMO GoB Configuration +22 end +23 group GoB Configuration +24 alt via O1 +25 SMO -> ODU: <> File ready notification to inform about file with new GoB +26 configuration +27 ODU -> SMO: <> File-download request +28 SMO -> ODU: <> Accepted +29 SMO -> ODU: <> Notification about successful file-download +30 ref over ODU, ORUs: <> Download file with new GoB configuration +31 ref over ODU, ORUs: gNB-DU Configuration Update +32 ref over ODU, ORUs: <> Carrier deactivation +33 ref over ODU, ORUs: <> New GoB Activation +34 ODU -> ORUs: <> (o-ran-beamforming.yang) +35 ORUs -> ODU: <> ... +36 ref over ODU, ORUs: gNB-DU Configuration Update +37 ref over ODU, ORUs: <> Carrier activation +38 else via OFH-MP +39 ref over SMO, ORUs: <> Download file with new mMIMO GoB configuration +40 SMO -> ODU: <> Notification about new GoB configuration file +41 ref over ODU, ORUs: <> Carrier deactivation +42 ref over ODU, ORUs: <> Activate new GoB configuration +43 ODU -> ORUs: <> (o-ran-beamforming.yang) +44 ORUs -> ODU: <> rpc reply +45 ref over ODU, ORUs: <> Carrier activation +46 end +47 end +48 +49 group ML Performance Monitoring +50 SMO --> SMO : Performance monitoring and evaluation +51 SMO --> SMO : Fallback (e.g. restore configuration) +52 SMO -> ODU: <> Default/Fallback mMIMO configuration +53 SMO --> rAPP : <> Model retraining and update +54 end +55 +56 @enduml + +``` + +![Flow diagram of GoB BF Optimization showing interactions between Personnel, Service Management & Orchestration Framework, E2 Nodes, O-RUs, and External components.](4eb3b972409332eeb79e6146cc43f3f2_img.jpg) + +The diagram illustrates the GoB BF Optimization process across five main components: Personnel (Operator), Service Management & Orchestration Framework (SMO & Non-RT RIC, rApps), E2 Nodes (O-CUs, O-DUs), O-RUs (O-RUs), and External (APP). The process is divided into several phases: + +- Data Collection:** + - 1 <> Data Collection (SMO & Non-RT RIC to rApps) + - 2 <> Data Collection (rApps to O-CUs) + - 3 <> Data Collection (O-CUs to O-DUs) +- ML Training:** + - 4 Data Retrieval (rApps to O-CUs) + - 5 AI/ML model training (O-CUs to O-DUs) +- ML Inference:** + - 6 Optimization Trigger/Target (Operator to SMO & Non-RT RIC) + - 7 Performance Degradation (SMO & Non-RT RIC to rApps) + - 8 <> Update Model Request (rApps to O-CUs) + - 9 <> Data Retrieval (O-CUs to O-DUs) + - 10 AI/ML model inference (O-DUs to O-CUs) + - 11 <> Optimal mMIMO GoB Configuration (O-CUs to SMO & Non-RT RIC) +- GoB Configuration:** + - 12 <> File ready notification to inform about file with new GoB configuration (SMO & Non-RT RIC to O-CUs) + - 13 <> File-download request (O-CUs to O-DUs) + - 14 <> Accepted (O-DUs to O-CUs) + - 15 <> Notification about successful file-download (O-CUs to SMO & Non-RT RIC) + - 16 <> (o-ran-beamforming.yang) (O-CUs to O-RUs) + - 17 <> ... (O-RUs to O-CUs) + - 18 <> Notification about new mMIMO GoB configuration file (SMO & Non-RT RIC to O-CUs) + - 19 <> (o-ran-beamforming.yang) (O-CUs to O-RUs) + - 20 <> (O-RUs to O-CUs) +- ML Performance Monitoring:** + - 21 Performance monitoring and evaluation (rApps to SMO & Non-RT RIC) + - 22 Fallback (e.g. restore configuration) (SMO & Non-RT RIC to rApps) + - 23 <> Default/Fallback mMIMO configuration (rApps to O-CUs) + - 24 <> Model retraining and update (O-CUs to O-DUs) + +Flow diagram of GoB BF Optimization showing interactions between Personnel, Service Management & Orchestration Framework, E2 Nodes, O-RUs, and External components. + +Figure 3.2.2.1-1. Flow diagram of GoB BF Optimization + +##### Requirements + +##### Required data: + +- 1) Environment data: Cell site information (e.g., location, inter-site distance), BS system configuration (e.g., operating frequency, bandwidth, frame structure, transmit power, default beam weight configuration), complete set of mMIMO configurations, i.e., horizontal/vertical beamwidth adjustable range, azimuth/elevation angle adjustable range. +- 2) From E2 Nodes (O-CUs and O-DUs): + - a) Essential: Measurement report options are forwarding UE's CSI (CQI, PMI, LI, RI, CRI) feedback information or covariance matrix (or any other compressed form of the information) from the UEs or newly defined Performance Management counters in the cells of interest; the time granularity of data collection should be configurable and satisfy the requirement of the AI/ML model. Any of the three input parameter options coherently support the GoB optimization use case but might support different implementation and deployment options. + - b) Optional: Network KPIs: cell downlink/uplink traffic load, RRC connection attempts, average RRC connected UEs, maximum RRC connected UE, DL/UL average active connections, DL/UL throughput, DL/UL spectral efficiency, NI (noise + interference), PH reports; beam resource usage (transmitted power per beam/directions and associated PRB usage), beam-based handover and beam failure statistics. +- 3) From External: + - a) Optional: User location related information, e.g. GPS information. + +| Input Data Options | | | | | | +|--------------------|-----------------|------------------------------------------------------------------------------------|----------------|------------------|--------------------------------------------------------------------------------------------------------------| +| Interface | Source → Target | Name/Description | Units | Reporting Period | New or existing measurement/reporting specification | +| O1 | O-DU → SMO | CSI report (CQI, PMI, LI, RI, CRI) per UE | CSI report | ~15min | Measurements defined in 3GPP TS 38.214 (section 5.2)

New reporting e.g. 3GPP TS 37.320 or O-RAN O1/E2 | +| O1 | O-DU → SMO | Channel covariance matrix (or any other compressed form of the information) per UE | Complex values | ~15min | New measurement e.g. 3GPP TS 38.215 or TS 38.314

New reporting. e.g. 3GPP TS 37.320 or, O-RAN O1/E2 | +| O1 | O-DU → SMO | PM counter for spatial distribution of estimated traffic density | count | ~15min | New measurement counter and new reporting e.g. 3GPP TS 28.552 | + +Table 3.2.2.1-1. + +##### Configuration data towards E2 Nodes: + +Optimized GoB beam pattern related configuration parameter: + +- 1) Towards O-DU + - a) via O1 transferring proprietary beamforming configuration files + - b) via Open FH M-Plane reading o-ran-beamforming YANG module. +- 2) Towards O-RU + - a) via Open FH M-Plane transferring proprietary beamforming configuration file + +| Output Data Options | | | | | | +|----------------------------|-------------------------|---------------------------------------------------|--------------|------------------------|-------------------------------| +| Interface | Source → Target | Name/Description | Units | Config. Period* | (Target) Specification | +| O1 | SMO → O-DU | Proprietary beamforming configuration file | file | ~x hours | O-RAN.WG5.MP Chapter 8 | +| Open FH M-Plane | O-RU → O-DU | Beamforming weights or attributes via YANG module | Values in IE | ~x hours | O-RAN.WG4.MP Section 12.4.2 | +| Open FH M-Plane | SMO → O-RU; O-DU → O-RU | Proprietary beamforming configuration file | File | ~x hours | O-RAN.WG4.MP Section 12.4.2 | +| Open FH CUS-Plane | O-DU → O-RU | Beamforming weights or attributes | Values in IE | ~x hours | O-RAN-WG4.CUS Section 5.4.2 | + +**Table 3.2.2.1-2.** + +##### ORAN Entity roles: + +- 1) SMO & Non-RT-RIC + - a) Collect the necessary configurations, performance indicators, and measurement reports from the E2 nodes (O-DU and O-CU), triggered by Non-RT RIC or rApp if required. + - b) Transfer file including optimized mMIMO GoB parameters via O1 (to O-DU) or Open FH M-Plane (to O-RU) interface. + - c) Transfer collected data towards rApp. + - d) Retrieve necessary UE location related information, e.g. GPS coordinates, from the application layer for the purpose of i) training relevant rAPPs and ii) execution of relevant rAPPs. + - e) Monitor the performance of the respective cells; when the optimization objective fails, initiate fallback procedure and/or trigger the rAPP model retraining and re-optimization. Execute the inference/control loop periodically or event-triggered. +- 2) rApps + - a) Retrieve necessary UE location related information, e.g. GPS coordinates, from the application layer for the purpose of training and execution of relevant AI/ML models. + - b) Infer an optimized GoB BF configuration. +- 3) O-DUs + - a) Collect and report to SMO KPIs related to user activity, traffic load and coverage, per beam/area, and information about beams and resource utilization. + - b) Apply GoB configuration received from the SMO over O1 or received from O-RU over Open FH M-Plane. + +- 4) O-CU + - a) Collect and report to SMO KPI related to QoS performance and handover/beam failures statistics. +- 5) O-RU + - a) Apply GoB configuration received from the SMO or from the O-DU over Open FH M-Plane. + +Note: Aggregated and disaggregated gNB architecture is supported. + +### 3.2.3 Impact Analysis on O-RAN Working Groups + +*Please note: This is an initial impact analysis as part of the WG1 UCTG work on mMIMO. The intention is to estimate the expected standardization effort within the O-RAN working groups. It is up to the WGs to decide how the mMIMO functionality should be specified in specifications of each WG.* + +#### WG1 (use cases, architecture) + +- O-RAN.WG1.Use-Cases-Analysis-Report-v05.00 + - Update use case 6: Massive MIMO Beamforming Optimization (Section 3.6) considering stage 1 and stage 2 decisions +- O-RAN.WG1.Use-Cases-Detailed-Specification-v05.00 + - Update use case 6: Massive MIMO Beamforming Optimization (Section 3.6) considering stage 1 and stage 2 decisions + +#### WG2 (Non-RT RIC, A1, R1) Impact + +- O-RAN.WG2.Use-Case-Requirements-v04.00 + - Add new use case 6: Massive MIMO Beamforming Optimization based on agreements from pre-normative phase +- O-RAN.WG2.Non-RT-RIC-ARCH-TS-v01.00.02 + - No impact identified + - O-RAN.WG2.R1.GAP-v01.00.00: + - Specifying retrieval of data collected, e.g., from the RAN over O1 or from external sources, towards the rApps is required (Step 4 in Figure 3.2.2.1-1). + - Specifying the means of transmitting a GoB BF configuration, resulting from the ML execution/inference, from the rApp to the SMO and further via O1 to the RAN nodes, is required (Step 9 in Figure 3.2.2.1-1). + - Not mMIMO use case specific impact: + - Specifying ML Model deployment is required (Step 6 in Figure 3.2.2.1-1). + - Specifying the means of transmitting an optimization target (or equivalent) to the rApp (ML Inference stage in Figure 3.2.2.1-1). + - Specifying ML Model performance monitoring roles and procedures is required (Steps 19 and 22 in Figure 3.2.2.1-1). + - Specifying the means of a fallback mechanism in case of unsatisfying rApp performance is required (Steps 20 and 23 in Figure 3.2.2.1-1). + +#### WG4 (O-FH) Impact + +- O-RAN.WG4.MP.0-v07.00.00 + - No impact identified + - Background + - Upload and download of files (Sections 9 and 5.3) + - Update of beamforming configuration files (Section 12.4) + - Activation and deactivation of affected carriers (o-ran-uplane-conf.yang) + - Activation of beamforming configuration by indicating the stored file (rpc commands in o-ran-beamforming.yang module e.g. activate-beamforming-config) + +- Notification of beamforming information update (beamforming-information-update in o-ran-beamforming.yang module) +- O-RAN-WG4.CUS.0-v07.00 + - No impact identified + - Background + - Predefined beams (uploaded via M-Plane) can be used if update is supported by O-RU + - Dynamic beamforming control option, see Section 5.4.2 using Information Elements + - ExtType=1 Beamforming Weights Extension Type, + - ExtType=2: Beamforming Attributes Extension Type, + - ExtType=11: Flexible Beamforming Weights Extension Type, + - ExtType=19: Section Compact multiple port beamforming information. Weight-based dynamic beamforming (Section 10.4.2), attribute-based dynamic beamforming (Section 10.4.3) and channel-information-based beamforming (Section 10.4.4) is supported + +#### WG5 (O1) Impact + +- O-RAN.WG5.O-CU-O1.0-v01.00 and O-RAN.WG5.MP.0-v02.00 + - Input parameter for GoB optimization are: + - forward UEs CSI measurement reporting + - reporting of channel covariance matrix (or any other compressed form of the information) + - new Performance Measurement counters for spatial distribution of estimated traffic density + - Impact depends on the selected option and + - is very limited when such measurements are specified in 3GPP specifications (related PM counter in 3GPP TS 28.552, CSI and channel covariance matrix in TS 37.320 etc.) and WG5 specs refer to 3GPP specifications or + - is moderate if such measurements are defined in O-RAN specifications + - Background + - Performance assurance management (Section 6) is aligned with O-RAN.WG10.O1-Interface.0-v05.00 + - File Management (Section 8) to transfer performance data files as well as notification files from O-CU-CP/O-CU-UP to SMO and vice versa. + - Provisioning Management (Section 9 in O-RAN.WG5.O-CU-O1.0-v01.00 or Section 10 in O-RAN.WG5.MP.0-v02.00) to configure trace/performance metric jobs (3GPP TS 28.622) + +#### WG10 (SMO, O1) Impact + +- O-RAN.WG10.O1-Interface.0-v05.00 + - No impact identified + - Background + - Provisioning management services is used to create/modify/delete/read/notify Managed Object Instance (MOI); this means instantiating performance metric jobs and trace jobs (Section 2.1) + - depending on the options: + - performance assurance management services (Section 2.3) collect performance measurement data + - trace management services collect measurements per UE (Trace, MDT, RCEF and RLF reporting) (Section 2.4) + +Summary: Impact on O-RAN specification will be very limited in case the input parameters for GoB optimization are specified in 3GPP and moderate if specified in O-RAN. The Open Fronthaul specification already supports file-based upload and download of GoB beam pattern on O-FH M-Plane as well as dynamic beamforming on O-FH CUS-Plane. + +### 3.2.4 Relation and Impact on 3GPP Specifications + +#### 3.2.4.1 Relation to 3GPP Coverage and Capacity Optimization (CCO) + +In Rel. 16, 3GPP carried out a study item on “RAN-centric data collection and utilization for LTE and NR” which resulted in several measurements to be supported for NR and being defined in 3GPP TS 28.552. In particular the use case “Capacity and Coverage Optimization” (CCO) related to GoB optimization was investigated and documented in the associated 3GPP TR 37.816. The study recommended the CCO function to be considered for normative specification. 3GPP RAN3 currently discusses CCO as part of the Rel.17 Work Item on “Enhancements of Data Collection for SON/MDT in NR”. While work is ongoing the following working assumptions have been made in 3GPP RAN3#113-e: + +- LTE CCO function should be considered as baseline for NG-RAN CCO solution for dynamic coverage changes with an index-based solution for coverage switching among deployment options. +- In NG-RAN scenario, a NG-RAN node may send to a neighbor NG-RAN node a coverage modification list which includes deployment related information concerning the serving cells. +- Xn signalling for coverage modification shall exchange at least the following information: NG-RAN CGI, Cell Coverage State, Cell Deployment Status Indicator and Cell Replacing Info in NG-RAN NODE CONFIGURATION UPDATE. +- DU signals to CU coverage related configuration information. Whether to include SSB beam information (on top of cell info) is FFS. +- CSI-RS based beam coverage tuning is an optimization and is not covered as part of NR CCO for Rel-17. +- DU makes the final decision on which coverage configuration to use. + +#### 3.2.4.2 Impact on 3GPP Specification + +##### Inter-gNB signalling (Xn) + +- 3GPP TS 38.423 NG-RAN; Xn Application Protocol (XnAP) + - Information about the Cell and SSB Beam Coverage State might be exchanged between gNB DUs to identify the SSB beam deployment configuration enabled by the respective gNB DU + - Target 3GPP Rel.17 + +##### Intra-gNB signalling (F1) + +- 3GPP TS 38.473 38.473 NG-RAN; F1 Application Protocol (F1AP) + - A Coverage Modification Notification might be sent from gNB DU to gNB CU as part of a configuration update message in case of changes on the Cell and SSB Beam Coverage State + - Target 3GPP Rel. 17 + +##### gNB measurements + +- 3GPP TS 38.314 NR; Layer 2 measurements + - The channel covariance matrix might be specified as new L2 measurement in RAN2. + +##### gNB measurement reporting + +- 3GPP TS 37.320 UTRA and E-UTRA and NG Radio Access; Radio measurement collection for Minimization of Drive Tests (MDT); Overall description; Stage 2 + - The new UE specific measurement reporting (channel covariance matrix and CSI feedback reporting) might be specified in the MDT framework in RAN2 +- 3GPP TS 28.552 Management and orchestration; 5G performance measurements + - New PM counters (e.g. spatial distribution of estimated traffic density or histogram of covariance matrix) might be specified in SA5 + +Summary: The related changes to 3GPP specifications for Inter- and Intra-gNB signalling are not essential to support GoB optimization in O-RAN. The related enhancements to 3GPP specifications for gNB measurements and measurement reporting are essential to support GoB optimization in O-RAN. + +### 3.2.5 Feasibility and Gain/Complexity Analysis + +#### 3.2.5.1 Trial Results + +Trail setup: + +- Product: AirScale MAA 64T64R n78 200W +- Frequency band: 3.5 GHz +- Standard: NR TDD +- Number of base stations: 1 +- Total output power: 200 W +- Sector opening angle: 120° +- Number of UEs: 1 and 20 +- Scenarios: UEs stationary as well as drive tests with shopping street +- Number of TX/RX paths: 64T / 64R +- Number of CSI-RS ports: 8 +- TRx configuration: 4x8x2 array (4 columns, 8 rows, 2polarizations) +- Channel type: actual channel in the field + +Trial results: + +- Baseline configuration: 6 beams uniformly horizontally spread with 6° down tilt + +![Figure 3.2.5.1-1: Two polar plots showing the radiation pattern of the Basic BeamSet #6. The left plot shows a wide, fan-shaped coverage area with multiple colored lines representing different beams. The right plot shows a more focused, narrow beam pattern. The text 'Basic BeamSet #6' is overlaid on the left plot.](d9952dfd89f7cf5167c12328516d9080_img.jpg) + +Figure 3.2.5.1-1: Two polar plots showing the radiation pattern of the Basic BeamSet #6. The left plot shows a wide, fan-shaped coverage area with multiple colored lines representing different beams. The right plot shows a more focused, narrow beam pattern. The text 'Basic BeamSet #6' is overlaid on the left plot. + +Figure 3.2.5.1-1. + +- Scenario: Single UE Drive Test + +![Figure 3.2.5.1-2: Three maps showing drive test results for Basic BeamSet #6, Optimized 6 beams, and Optimized 6 beams (KDE). Each map shows a route with signal strength color-coded from green (strong) to red (weak).](d74fddb8ff3a4f59b2366861b52257ab_img.jpg) + +Figure 3.2.5.1-2. + +--- + +Copyright © 2022 by the O-RAN ALLIANCE e.V. +Your use is subject to the terms of the O-RAN Adopter License Agreement in Annex ZZZ. + +20 + +Figure 3.2.5.1-2: Three maps showing drive test results for Basic BeamSet #6, Optimized 6 beams, and Optimized 6 beams (KDE). Each map shows a route with signal strength color-coded from green (strong) to red (weak). + +- Weighted RSRP measurements - Single UE Drive Test + +![CDF plot of RSRP - Drive Test on Day 9 & 10. The plot shows three curves: Baseline-6Beams (blue), Optimize-6Beams (orange), and Kde optimize-6Beams (yellow). The x-axis is RSRP in dBm, ranging from -130 to -60. The y-axis is F(x), ranging from 0 to 1. A legend indicates Mean values: Baseline -100.91dBm, Optimize -96.34dBm, and Kde Optimize -96.90dBm.](d465a67b3dbeeda30a0330085be7809f_img.jpg) + +CDF plot of RSRP - Drive Test on Day 9 & 10. The plot shows three curves: Baseline-6Beams (blue), Optimize-6Beams (orange), and Kde optimize-6Beams (yellow). The x-axis is RSRP in dBm, ranging from -130 to -60. The y-axis is F(x), ranging from 0 to 1. A legend indicates Mean values: Baseline -100.91dBm, Optimize -96.34dBm, and Kde Optimize -96.90dBm. + +Figure 3.2.5.1-3. + +- Scenario: 20 UEs drive tests including shopping street + +![Two maps comparing RSRP measurements with 6 Baseline Beams and 6 Optimized beams. The left map shows 'With 6 Baseline Beams' and the right map shows 'With 6 Optimized beams'. Both maps show a shopping street with 16 UEs and 2 UEs moving. The color scale for RSRP before optimization ranges from -121 to -94 dBm, and after optimization it ranges from -119 to -86 dBm.](38f727ca5c261d11a408497c67dfa164_img.jpg) + +Two maps comparing RSRP measurements with 6 Baseline Beams and 6 Optimized beams. The left map shows 'With 6 Baseline Beams' and the right map shows 'With 6 Optimized beams'. Both maps show a shopping street with 16 UEs and 2 UEs moving. The color scale for RSRP before optimization ranges from -121 to -94 dBm, and after optimization it ranges from -119 to -86 dBm. + +Figure 3.2.5.1-4. + +- Weighted RSRP measurements – 20 UEs drive tests including shopping street + +![CDF plot of UE RSRP. The plot shows two curves: baseline-6Beams (blue) and optimized-6Beams (orange). The x-axis is RSRP in dBm, ranging from -125 to -75. The y-axis is F(x), ranging from 0 to 1. A text box indicates 'Weighted RSRP gain of 8.2 dB'.](d7b32db967fa51a1a6a61e40a676c5a2_img.jpg) + +CDF plot of UE RSRP. The plot shows two curves: baseline-6Beams (blue) and optimized-6Beams (orange). The x-axis is RSRP in dBm, ranging from -125 to -75. The y-axis is F(x), ranging from 0 to 1. A text box indicates 'Weighted RSRP gain of 8.2 dB'. + +Figure 3.2.5.1-5. + +The ML based beam pattern optimization algorithm can adapt to the traffic distribution and hence provides a significant gain in terms of weighted downlink RSRP. Uplink throughput enhancements are also expected since SSB beams are used for uplink receive beamforming. + +## 3.3 Solution 2: Beam-based Mobility Robustness Optimization (bMRO) + +### 3.3.1 Problem Statement, Solution, and Value Proposition + +Mobility Robustness Optimization is a well-known SON concept. First supporting measurements have been specified in LTE in Release 9. Its principle is to configure a number of parameters in the eNB that can delay or advance the HO procedure between two neighboring cells. The two parameters are 1. the cell individual offset (CIO) and 2. the time-to-trigger (TTT). One CIO value is a reference signal received power offset specific to one neighbor cell, stored in the eNB. The TTT value is a time offset specific to one neighbor cell, stored in the eNB. + +By changing the CIO and the TTT, the operator may solve the following problems: + +1. Unbalanced traffic between neighboring cells. +2. Low performance of cell edge users. +3. Poor handover performance. + +In particular, the prime use of optimizing the CIO and the TTT values is reducing the number of anomalous or problematic HO events between neighbor cells. + +In a 5G mMIMO cell/gNB whose coverage is provided not by a single beam but by several beams which radiate in different directions. Thus, from the UEs point of view, the border between two neighbor cells is not a single border anymore but degenerates to several beam→cell (or beam→beam) borders, where the one beam is radiated by the source gNB and another beam is radiated from the target gNB. In this scenario, using a single CIO+TTT value pair on a cell→cell basis will be suboptimal, as one beam→cell (or beam→beam) border might require a different CIO+TTT configuration for optimal HOs than another beam→cell (or beam→beam) border. + +This solution proposes to employ beam-specific CIO and TTT values between neighbor cells, e.g., instead of a single CIO+TTT value pair for the cell1→cell2 border, to employ a CIO+TTT value pair for the SourceCell[Beam1]→TargetCell and SourceCell[Beam2]→TargetCell borders. + +The value of this solution is that the number of anomalous and problematic HOs can be resolved on a beam→cell basis, i.e., with much finer granularity than with the legacy SON cell→cell solution. + +### 3.3.2 Architecture/Deployment Options + +#### 3.3.2.1 Option 1 + +The Near-RT RIC may host an xApp to optimize inter-cell beam mobility such as bMRO. In this case the Near-RT RIC might for instance configure beam individual offsets and the beam individual TTT for inter-cell mobility decisions. The learning and the inference of the parameters may be done on individual beam→cell (or beam→beam) borders or collectively on a group of beam→cell borders, depending on the implementation. The optimization might follow an operator/SMO defined objective (e.g., minimize number/rate of TE HOs, TL HOs, or ping-pong HOs; optimize for certain beam→cell borders; constrained optimization based on other objectives etc.), and so might be triggered by a new operator/SMO defined optimization target, detection of performance degradation, or a change in the radio environment (e.g., change in the mMIMO Beam Pattern). + +``` + +1 +2 @startuml +3 skinparam ParticipantPadding 5 +4 skinparam BoxPadding 10 +5 skinparam defaultFontSize 12 +6 Autonumber +7 +8 Box "SMO" #gold +9 Participant SMO as "Operator/SMO" +10 Participant NON as "Non-RT RIC" +11 end box +12 +13 Box "O-RAN" #lightpink +14 Participant NearRTRIC as "Near-RT RIC" +15 Participant ORANnodes as "E2 Nodes" +16 End box +17 +18 group Data Collection +19 ORANnodes -> NearRTRIC : <> KPI/PM report +20 Hnote over NearRTRIC +21 mMIMO Beam Pattern Information is available +22 Endhnote +23 end +24 +25 group AI/ML Flow +26 SMO -> NearRTRIC: <> Initialize/Provide ML Model +27 ORANnodes -> NearRTRIC: <> KPI/PM report +28 Hnote over NearRTRIC +29 mMIMO Beam Pattern Information is available +30 Endhnote +31 NearRTRIC -> NearRTRIC: AI/ML model training +32 NearRTRIC -> NearRTRIC: AI/ML model inference +33 end +34 +35 group Configuration Update +36 group alt 1 +37 Hnote over NearRTRIC +38 mMIMO Beam Pattern Change +39 Endhnote +40 end +41 group alt 2 +42 SMO -> NearRTRIC: <> Optimization Trigger:\nNew optimization target +43 end +44 group alt 3 +45 NearRTRIC -> NearRTRIC: Optimization Trigger:\nPerformance degradation +46 end +47 NearRTRIC -> ORANnodes: <> Configure new mobility parameters +48 end +49 +50 group Performance Monitoring +51 ORANnodes -> NearRTRIC: <> KPI/PM report +52 NearRTRIC -> NearRTRIC: Performance monitoring and evaluation +53 NearRTRIC -> NearRTRIC: Fallback configuration (O) +54 NearRTRIC -> NearRTRIC: Model retraining and update +55 end +56 +57 @enduml +58 + +``` + +![Sequence diagram for mMIMO solution showing interactions between SMO and O-RAN components across four phases: Data Collection, AI/ML Flow, Configuration Update, and Performance Monitoring.](a64ca3bd463359470a1aa7cc9c043390_img.jpg) + +``` + +sequenceDiagram + participant SMO as SMO + participant O_RAN as O-RAN + participant Operator_SMO as Operator/SMO + participant Non_RT_RIC as Non-RT RIC + participant Near_RT_RIC as Near-RT RIC + participant E2_Nodes as E2 Nodes + + Note over SMO: Data Collection + E2_Nodes->>Near_RT_RIC: 1 <> KPI/PM report + Note over Near_RT_RIC: mMIMO Beam Pattern Information is available + + Note over SMO: AI/ML Flow + Operator_SMO->>Near_RT_RIC: 2 <> Initialize/Provide ML Model + E2_Nodes->>Near_RT_RIC: 3 <> KPI/PM report + Note over Near_RT_RIC: mMIMO Beam Pattern Information is available + Near_RT_RIC->>Near_RT_RIC: 4 AI/ML model training + Near_RT_RIC->>Near_RT_RIC: 5 AI/ML model inference + + Note over SMO: Configuration Update + alt alt 1 + Note over Near_RT_RIC: mMIMO Beam Pattern Change + end + alt alt 2 + Operator_SMO->>Near_RT_RIC: 6 <> Optimization Trigger: New optimization target + end + alt alt 3 + Near_RT_RIC->>Near_RT_RIC: 7 Optimization Trigger: Performance degradation + end + Near_RT_RIC->>E2_Nodes: 8 <> Configure new mobility parameters + + Note over O_RAN: Performance Monitoring + E2_Nodes->>Near_RT_RIC: 9 <> KPI/PM report + Near_RT_RIC->>Near_RT_RIC: 10 Performance monitoring and evaluation + Near_RT_RIC->>Near_RT_RIC: 11 Fallback configuration (O) + Near_RT_RIC->>Near_RT_RIC: 12 Model retraining and update + +``` + +The diagram illustrates the mMIMO solution architecture and its operational flow. It is divided into four main phases: Data Collection, AI/ML Flow, Configuration Update, and Performance Monitoring. The SMO (Service Based Interface) is represented by a yellow box containing the Operator/SMO and Non-RT RIC. The O-RAN is represented by a pink box containing the Near-RT RIC and E2 Nodes. The flow starts with Data Collection where E2 Nodes send KPI/PM reports to the Near-RT RIC. This is followed by the AI/ML Flow where the Operator/SMO sends initialization commands and receives reports, and the Near-RT RIC performs model training and inference. The Configuration Update phase includes alternative triggers for optimization (new target or performance degradation) leading to the configuration of new mobility parameters. Finally, the Performance Monitoring phase involves continuous reporting from E2 Nodes, evaluation by the Near-RT RIC, and model retraining as needed. + +Sequence diagram for mMIMO solution showing interactions between SMO and O-RAN components across four phases: Data Collection, AI/ML Flow, Configuration Update, and Performance Monitoring. + +Figure 3.3.2.1-1. mMIMO solution diagram + +One of the necessary inputs for training and inference of the mMIMO function is the (current) mMIMO Beam Pattern that is determined externally (in the SMO, in the Non-RT RIC, in the E2 Nodes, or in the Near-RT RIC by another function). The relevant mMIMO Beam Pattern Information must be available at the Near-RT RIC mMIMO function both for training and inference. Depending on implementation, this can be achieved by transmission from the SMO (over O1), or by transmission from the E2 Nodes (over E2), or by combined transmission from the SMO and the E2 Nodes, or by communication between two Near-RT RIC functions. Moreover, depending on how the relevant mMIMO Beam Pattern Information is configured/determined, the necessary information may be transmitted separately and asynchronously (e.g., SMO transmits a list of mMIMO Beam Patterns for the next time period(s), while the E2 Nodes transmit the exact times of the mMIMO Beam Pattern changes and indicate the IDs of the mMIMO Beam Patterns in the list). + +##### Requirements + +| Input Data | | | | | | +|------------|--------------------|---------------------------------------------------------------------|-------|-------------------|--------------------------------| +| Interface | Source Target → | Name/Description | Units | Reporting Period* | (Target) Specification | +| E2 | O-CU → Near-RT RIC | Number of too early HOs from a given beam to a given neighbor cell | count | ~1 min | 3GPP TS 28.552 (Sec. 5.1.1.25) | +| E2 | O-CU → Near-RT RIC | Number of too late HOs from a given beam to a given neighbor cell | count | ~1 min | 3GPP TS 28.552 (Sec. 5.1.1.25) | +| E2 | O-CU → Near-RT RIC | Number of attempted HOs from a given beam to a given neighbor cell | count | ~1 min | 3GPP TS 28.552 (Sec. 5.1.1.25) | +| E2 | O-CU → Near-RT RIC | Number of successful HOs from a given beam to a given neighbor cell | count | ~1 min | 3GPP TS 28.552 (Sec. 5.1.1.25) | +| E2 | O-CU → Near-RT RIC | Number of failed HOs from a given beam to a given neighbor cell | count | ~1 min | 3GPP TS 28.552 (Sec. 5.1.1.25) | + +Table 3.3.2.1-1. + +| Output Data | | | | | | +|-------------|--------------------|-----------------------------------------------|-------|-----------------------|-----------------------------------------| +| Interface | Source Target → | Name/Description | Units | Config. Period* | (Target) Specification | +| E2 | Near-RT RIC → O-CU | CIO for a given beam to a given neighbor cell | dB | trigger-based ≥ 1 min | 3GPP TS 38.331 (Sec. 5.3.5, Sec. 5.5.4) | + +Table 3.3.2.1-2. + +*\*The period represents the baseline assumption for the gain/complexity analysis in this document. Faster reporting and reconfiguration periods or even different input data over E2 for faster Near-RT RIC control loops are not excluded for the normative phase if seen beneficial.* + +##### O-RAN Entity roles: + +- 1) SMO & Non-RT RIC + - a) Trigger bMRO configuration. (O) + - b) Send bMRO configuration target to Near-RT RIC. + - c) Send mMIMO Beam Pattern related information (Beam Pattern configuration, Beam Pattern configuration list, Beam Pattern configuration switch timing/condition, Beam Pattern identifier etc.) to the Near-RT RIC. + - d) Trigger initiation of bMRO AI/ML Model training. + - e) Non-RT RIC + - f) Transfer the appropriate bMRO ML model to the Near-RT RIC over O1/O2. +- 2) Near-RT RIC + - a) Retrieve necessary configurations, performance indicators, measurement reports and other data from E2 nodes for the purpose of training of relevant AI/ML models. Retrieve ML Models from the Non-RT RIC over O1/O2. + - b) Train the relevant AI/ML model using the collected data. FFS: Perform offline training of relevant AI/ML models. + - c) Use the trained AI/ML models to infer the correlation between the Grid-of-Beam configuration, handover, and beam failure statistics of multiple cells and beams, and to predict the optimal configuration of mobility parameters (e.g., beam individual offsets for beam mobility) for each cell/beam pair optionally according to a global optimization objective designed by the operator and retrieved from the SMO. + - d) Send the optimal per beam mobility parameter configurations to E2 nodes. + - e) Monitor the performance of the AI/ML model based on configurations, performance indicators, and measurement reports received from the RAN. + - f) Retrain the AI/ML model and re-optimize the beam mobility configurations based on the monitored performance and/or based on a switch of the Grid-of-Beam configuration. + - g) Execute the control loop periodically or event-triggered. + - h) Retrieve mMIMO Beam Pattern related information from the SMO. +- 3) E2 nodes + - a) Collect and report to Near-RT RIC KPIs related to Grid-of-Beam configuration, handover and beam failure statistics. + - b) Apply L3 beam mobility parameter configuration following Near-RT RIC configuration. + - c) Send mMIMO Beam Pattern related information to the Near-RT RIC. + +#### 3.3.2.2 Option 2 + +The bMRO optimization algorithm might also be hosted in Non-RT RIC. Same principles apply, whereas KPI reporting and configuration management over O1 interface will be used. + +### 3.3.3 Impact Analysis on O-RAN Working Groups + +*Editor's note: This is an initial impact analysis as part of the WG1 UCTG work on mMIMO. The intention is to estimate the expected standardization effort within the O-RAN working groups. It is up to the WGs to decide how the mMIMO functionality should be specified in specifications of each WG.* + +#### WG1 (use cases, architecture) Impact + +- O-RAN.WG1.Use-Cases-Analysis-Report-v05.00 + - Update use case 6: Massive MIMO Beamforming Optimization (Section 3.6) considering stage 1 and stage 2 decisions +- O-RAN.WG1.Use-Cases-Detailed-Specification-v05.00 + +- Update use case 6: Massive MIMO Beamforming Optimization (Section 3.6) considering stage 1 and stage 2 decisions + +#### WG2 (Non-RT RIC, A1) Impact + +- O-RAN.WG2.Use-Case-Requirements-v04.00 + - If seen as beneficial, add new use case 6: Massive MIMO Beamforming Optimization based on agreements from pre-normative phase +- O-RAN.WG2.AIML-v01.03 + - Depending on implementation, add a deployment scenario involving offline training in the Near-RT RIC. + +#### WG3 (Near-RT RIC, E2) Impact + +- O-RAN.WG3.UCR-v01.00 + - Add new use case 6: Massive MIMO Beamforming Optimization based on agreements from pre-normative phase +- O-RAN.WG3.RICARCH-v02.00 + - No impact identified + - Background information + - bMRO is an xApp running in the Near-RT RIC + - bMRO is using Near-RT RIC services REPORT and POLICY and uses the E2 interface to a) get KPI/PM reports from the E2 Node and b) configure beam-based cell individual offsets as policy in the E2 Node. +- O-RAN.WG3.E2GAP-v02.00 + - No impact identified + - Background information + - bMRO xApp uses the E2 interface to a) get KPI/PM reports from the E2 Node and b) configure beam-based cell individual offsets as policy in the E2 Node. + - The following services of the E2 interface are used: + 1. E2 KPI/PM report (Figure 3.3.2.1-1: step 3, step 9) using Near-RT RIC REPORT Service + 2. E2 Configure new mobility parameters (Figure 3.3.2.1-1: step 8) using Near-RT RIC POLICY Service +- O-RAN.WG3.E2AP-v02.00 + - No impact identified + - Background information + - The following services of the E2 interface are used: + 3. E2 KPI/PM report (Figure 3.3.2.1-1: step 3, step 9) using Near-RT RIC REPORT Service + 4. E2 Configure new mobility parameters (Figure 3.3.2.1-1: step 8) using Near-RT RIC POLICY Service +- O-RAN.WG3.E2SM-RC-v01.01.00 or NEW: O-RAN.WG3.E2SM-CC + - Add RAN POLICY service “Mobility Robustness Optimization” with Policy Approach “Offset” to E2SM-RC (modify E2SM-RC to support cell specific signaling) or add this policy to a new Cell level/E2 Node level Control (i.e. E2SM-CC) +- O-RAN.WG3.E2SM-KPM-v02.00 + - No direct impact identified + - Assuming the new measurements will be specified in 3GPP TS 28.552 + - Dependency on completion of bMRO functionality in 3GPP Rel.17 + - Background + - The E2 Node (O-CU-CP) shall host the RAN Function “KPM Monitor” + +#### WG5 (O1) Impact + +- O-RAN.WG5.O-CU-O1.0-v01.00 + - No direct impact identified + +- Assuming data model (provisioning management) will be enhanced with beam individual offsets in 3GPP TS 28.541 (according to *cellIndividualOffset* in module *\_3gpp-nr-nrm-nrcellrelation.yang*) +- Assuming performance measurements in 3GPP TS 28.552 are enhanced to consider HO failures TooEarly, Too Late and ToWrongCell per beam; +- Assuming information about assignment of UE to beam is available at CU (using UE context messages specified in 3GPP TS 38.473 to indicate) +- Dependency in completion of bMRO functionality in 3GPP Rel.17 +- Background + - Performance management (Section 6) is aligned with O-RAN.WG10.O1-Interface.0-v05.00 + - File Management (Section 8) to transfer configuration files as well as performance data files and notification log files. + - Provisioning Management (Section 9 in O-RAN.WG5.O-CU-O1.0-v01.00 and O-RAN.WG5.MP.0-v02.00 or Section 10 in O-RAN.WG5.MP.0-v02.00) to transmit trigger, to configure beam individual offsets and to configure performance metric jobs (3GPP TS 28.622). + +#### WG10 (SMO, O1) Impact + +- O-RAN.WG10.O1-Interface.0-v05.00 + - No impact identified + - Background + - Provisioning management services (Section 2.1) allow configuration changes using NETCONF (TS 28.532, TS 28.541) + - Performance assurance management services (Section 2.3) collect performance measurement data for file reporting (File management services explained in Section 2.5) or data streaming + +Summary: The impact on O-RAN specification is quite limited, assuming bMRO related KPIs are specified in 3GPP SA5. Work in O-RAN WGs can be minimized by referring to 3GPP specification as done today, e.g., E2SM-KPM, O-RAN.WG5.O-CU-O1, O-RAN.WG10.O1. + +### 3.3.4 Relation and Impact on 3GPP Specification + +#### 3.3.4.1 3GPP Mobility Robustness Optimization + +LTE MRO is a well-known SON method that optimizes the mobility parameters and thereby minimizes the mobility related failures as well as unnecessary handovers (HOs). First the following radio link or handover failure causes are identified: + +1. Too late handovers (TL) +2. Too early handovers (TE) +3. Handover to wrong cell +4. Ping-pong (PP) handovers + +For this purpose, eNBs and UEs evaluate radio link or handover failure related information. UEs might provide respective information after radio link re-establishment and neighbour eNBs might exchange respective failure indications. + +SON MRO was first standardized in LTE Rel.9: + +- 3GPP TS 36.902 E-UTRAN; SON Use Cases and Solutions +- 3GPP TS 36.300 E-UTRAN; Overall description stage 2 +- 3GPP TS 36.423 E-UTRAN; X2 Application Protocol (X2AP) + - New X2-AP procedures: *Radio Link Failure Indication* + - New X2-AP procedure: *Handover Report Indication* +- 3GPP TS 36.331 E-UTRA; Radio Resource Control (RRC) + - RLF report indication (UE assistance signalling for root cause analysis) + +- 3GPP TS 32.425 Performance Management (PM); Performance measurements E-UTRAN + - KPIs for Too-Late HOs (TL), Too-Early HOs (TE), HO to wrong cell, Ping-pong (PP) +- 3GPP TS 28.658 E-UTRAN Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS) + - Configuration management of MRO Cell Individual Offsets (CIO) + +LTE Rel.10 specified that RLF Report will also be available after UE went to Idle mode (Re-establishment was not successful). LTE Rel.11 supports signalling between base stations for Inter-RAT support. + +MRO functionality was added to NR and NG-RAN in Rel.16: + +- 3GPP TS 38.300 E-UTRAN; Overall description stage 2 +- 3GPP TS 38.423 NG-RAN; Xn Application Protocol (XnAP) +- 3GPP TS 38.331 NR; Radio Resource Control (RRC) +- 3GPP TS 28.552 Management and orchestration; 5G performance measurements + - KPIs for Too-Late HOs (TL), Too-Early HOs (TE), HO to wrong cell, Ping-pong (PP) +- 3GPP TS 28.541 Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3 + - Configuration management of MRO Cell Individual Offsets (CIO) + +NR and NG-RAN MRO includes connection failure due to intra-system as well as inter-system mobility, inter-system unnecessary HO as well as inter-system ping-pong handover. + +Overall, LTE and NR MRO are essential mobility features that can reduce dominating radio link failures, make handover more robust and also reduce handover ping-pong effects by adapting cell individual offsets. 3GPP is also working to extent the concept to support mMIMO with beam-based approaches for MRO. + +#### 3.3.4.2 Impact of bMRO on 3GPP Specification + +gNB reporting + +- 3GPP TS 28.552 Management and orchestration; 5G performance measurements + - Beam-based KPIs for Too-Late HOs (TL), Too-Early HOs (TE), HO to wrong cell + - CR S5-214485 submitted to 3GPP SA5 at 3GPP TSG-SA5 Meeting #138-e meeting, 23rd Aug 2021 - 31st Aug 2021; Conclusion: noted + - CR S5-215326 submitted to 3GPP SA5 at 3GPP TSG-SA5 Meeting #139-e meeting, 11th Oct 2021 – 20th Oct 2021 + - Target 3GPP Rel.17 +- 3GPP TS 28.313 Management and orchestration; Self-Organizing Networks (SON) for 5G networks + - Add beam based KPIs for too early handover failures, too late handover failures, handover failures to wrong cell + - Target 3GPP Rel. 17 + +gNB configuration + +- 3GPP TS 28.541 Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3 + - Beam-based configuration management of MRO Cell Individual Offsets (CIO) + - CR S5-215328 (stage 2) and CR S5-215348 (stage 3) submitted to 3GPP SA5 at 3GPP TSG-SA5 Meeting #139-e meeting, 11th Oct 2021 – 20th Oct + - Target 3GPP Rel.17 + +UE configuration and reporting + +- 3GPP TS 38.331 NR; Radio Resource Control (RRC) protocol specification + - Add UE configuration of beam-based individual offsets for MRO + - Add UE reporting of last serving beam in the RLF report + - CR on 3GPP TS 38.331 should be submitted to 3GPP RAN2 + +- Target 3GPP Rel. 17 + +##### Intra-gNB signalling (F1) + +- 3GPP TS 38.473 NG-RAN; F1 Application Protocol (F1AP) + - Signalling needed on F1AP to support the per-beam mobility setting change + - TDoc 3GPP R3-213388 “Consideration on the CU-DU impacts of the per-beam mobility setting change” submitted to 3GPP TSG-RAN WG3 Meeting #113-e meeting, 16th – 27th August 2021 + - CR 3GPP R3-213389 “Enabling CU-DU information exchange to support per-beam mobility setting change” submitted to 3GPP TSG-RAN WG3 Meeting #113-e meeting, 16th – 27th August 2021 + - Target 3GPP Rel. 17 + +Summary: The related changes to 3GPP specifications for gNB reporting, gNB configuration and intra-gNB signalling are essential to support bMRO optimization in O-RAN. First CRs to 3GPP SA5 and RAN3 have been submitted as part of 3GPP Rel.17 and are currently being revised. Completion of bMRO in O-RAN can only take place after completion of bMRO in 3GPP, which should be considered in the mMIMO feature plan. + +The related changes to 3GPP specifications for UE configuration and UE reporting are not essential to support bMRO optimization in O-RAN. Contribution to 3GPP RAN2 is still open and under discussion. + +### 3.3.5 Feasibility and Gain/Complexity Analysis + +#### 3.3.5.1 Simulation Results + +Simulation setup: + +- 7 site hexagonal grid scenario (3GPP TR38.901 Urban Micro, ISD=200m) +- center frequency: 28 GHz (FR2), bandwidth: 100 MHz +- 16x8 antennas +- 8+4 beams (8 narrow beams with lower down tilt, 4 broader beams with higher down tilt) +- 4 simultaneous beams (maximum number of active beams for transmission within a cell used for spatial multiplexing) +- BS height: 10 m, mechanical tilt: 9° +- SSB beams with 15MHz bandwidth +- KPI period: 30 seconds +- Number of UEs: 630 UEs total (210 slow UEs + 420 street UEs) +- Traffic: full buffer + +![Figure 3.3.5.1-1: A 2D plot showing a hexagonal grid of cells. A central 3x3 grid of cells is highlighted with a pink border. Blue arrows represent the movement of user equipment (UE) across the grid. Black circles represent base stations. The legend indicates: Base Station (black circle), slow UE 3km/h (blue arrow), and street UE 30km/h (pink line).](28be4653b90cccbe7ee396890e08cc80_img.jpg) + +• Example mobility: +Mobility 30s + +Figure 3.3.5.1-1: A 2D plot showing a hexagonal grid of cells. A central 3x3 grid of cells is highlighted with a pink border. Blue arrows represent the movement of user equipment (UE) across the grid. Black circles represent base stations. The legend indicates: Base Station (black circle), slow UE 3km/h (blue arrow), and street UE 30km/h (pink line). + +Figure 3.3.5.1-1. + +- A3 Trigger with 80 ms TTT (time-to-trigger) and 2dB total offset, 60 ms L3 filtering + +Simulation Results: + +- 3 KPI periods = 90 s +- Reduction of the number of TE (too early) HOs and TL (too late) HOs: + +![Figure 3.3.5.1-2: Two bar charts comparing TL and TE events across three scenarios: baseline, MRO, and beam-based MRO. The left chart shows TL [Events] and the right chart shows TE [Events].](3aa8d8f171a935e0864621c9c8494383_img.jpg) + +| Scenario | TL [Events] | TE [Events] | +|----------------|-------------|-------------| +| baseline | 590 | 72 | +| MRO | 135 | 40 | +| beam-based MRO | 57 | 31 | + +Figure 3.3.5.1-2: Two bar charts comparing TL and TE events across three scenarios: baseline, MRO, and beam-based MRO. The left chart shows TL [Events] and the right chart shows TE [Events]. + +Figure 3.3.5.1-2. + +The beam-based MRO can reduce the number of total network TL failures by 90% compared to the baseline (no MRO) and by 58% compared to legacy MRO (left graph). The beam-based MRO can reduce the total number of network TE failures by 57% compared to the baseline and by 23% compared to legacy MRO (right graph). + +- Reduction of total network outage rate and failures: + +![Figure 3.3.5.1-3: Two bar charts comparing baseline, MRO, and beam-based MRO for Outage Rate and All Mobility Failures.](c1204951d9b0786ba1d406ae059d5f3a_img.jpg) + +Figure 3.3.5.1-3 consists of two bar charts comparing the performance of baseline, MRO, and beam-based MRO. The left chart shows the Outage Rate [%] and the right chart shows All Mobility Failures [Events/UE/min]. + +| Metric | baseline | MRO | beam-based MRO | +|---------------------------------------|----------|------|----------------| +| Outage Rate [%] | 1.31 | 0.88 | 0.74 | +| All Mobility Failures [Events/UE/min] | 0.79 | 0.22 | 0.14 | + +Figure 3.3.5.1-3: Two bar charts comparing baseline, MRO, and beam-based MRO for Outage Rate and All Mobility Failures. + +Figure 3.3.5.1-3. + +The beam-based MRO can reduce the outage rate by 44% compared to the baseline and 17% compared to legacy MRO (left graph). The beam-based MRO can reduce the total network failure by 82% compared to the baseline and by 34% compared to legacy MRO (right graph). + +- Reduction of the rate of network ping-pong (PP) failures: + +![Figure 3.3.5.1-4: Two bar charts comparing baseline, MRO, and beam-based MRO for Ping-Pong and HO success rates.](02377c601cba92e8bad617c718f91b13_img.jpg) + +Figure 3.3.5.1-4 consists of two bar charts comparing the performance of baseline, MRO, and beam-based MRO. The left chart shows the Ping-Pong [Events/UE/min] and the right chart shows HO success [Events/UE/min]. + +| Metric | baseline | MRO | beam-based MRO | +|----------------------------|----------|------|----------------| +| Ping-Pong [Events/UE/min] | 0.4 | 0.61 | 0.33 | +| HO success [Events/UE/min] | 6.53 | 6.43 | 5.57 | + +Figure 3.3.5.1-4: Two bar charts comparing baseline, MRO, and beam-based MRO for Ping-Pong and HO success rates. + +Figure 3.3.5.1-4. + +The beam-based MRO can reduce the rate of PP handovers by 18% compared to the baseline and by 46% compared to legacy MRO (left graph). As the result of the reduction in the rate of PP handovers, the total frequency of HOs can be reduced by 15% compared to the baseline and by 13% compared to legacy MRO (right graph). + +#### 3.3.5.2 Complexity Analysis + +Analysis is provided relative the legacy LTE MRO implementation. + +The computational complexity as well as the signalling overhead (reporting from the E2 Node (O-CU) as well as configuration towards the E2 Node (O-CU)) increases as follows: + +- Computational complexity: $O([\text{No. of beams}] \times [\text{MRO complexity}])$ +- Increase of signaling: $O([\text{No. of beams}] \times [\text{MRO signalling}])$ + +The computational complexity may be reduced by enhanced proprietary implementations, e.g., forming virtual groups of beams with similar characteristics, e.g., neighbor beams covering the same street or area. With such an implementation the computational complexity can be reduced to: + +- Computational complexity: $O([No. \text{ of beam groups}] \times [MRO \text{ complexity}])$ +- Increase of signaling: $O([No. \text{ of beam groups}] \times [MRO \text{ signalling}])$ + +Overall computational complexity seems reasonable since the time frequency of inter-cell handover events is relatively low and even decreases with the introduction of beam-based MRO. Similarly, the necessary signaling frequency (KPI reporting as well as configuration of Cell Individual Offsets) is rather low, e.g., in the range of seconds in the worst case. + +## 3.4 Solution 3: AI/ML Based Initial Access (SS Burst Set), CSI-RS and DMRS Configuration Optimization + +### 3.4.1 Problem Statement and Value Proposition + +3GPP NR based wireless cellular networks promises to provide leaner system design compared to its predecessors in a bid to improve spectral efficiency, power consumption performance and reduce interferences. Ultra-lean design aims to minimize “always on” reference signal transmissions in the downlink. Impact is more on Massive MIMO (mMIMO) system and networks where gNB/TRP should transmit downlink reference signals only when necessary. List of “always on” reference signals include synchronization signals (SS Burst Sets), CSI-RS TRS, CSI-RS Acquisition, DMRS and system broadcast information. Subsequent sections present AI/ML based optimization problem description with SS Burst Set configuration optimization which operates in slowest control loop (Non-RT RIC Control Loop) of the O-RAN architecture. Gradually problem statement is extended to CSI-RS and DMRS configuration optimizations operating in Near-RT RIC and O-DU control loops. + +In beamformed Massive MIMO systems, initial access (IA) and time frequency tracking (TA) mechanisms require transmission of “Always On” signals SS Burst Sets periodically followed by CSI-RS TRS in the remaining part of the frame structure. During initial access process, the UE detects a preferred SS/PBCH beam at preferred receive beam. UEs with beam correspondence support can use the same receive beam to transmit PRACH after receiving SIB1 on the scheduled SS/PBCH time-frequency grids. When beam correspondence is not supported, the UE repeats PRACH transmissions in different directions and then listen for the network response using the same beam used to detect the SS/PBCH. From the initial access procedure, a default beam pair is established. After SS burst based synchronization, the UE can start synchronizing with gNB/TRP using SS Block configuration dependent CSI-RS signals. + +In large scale NR networks with thousands of gNB/TRPs deployed, system configurations derived manually using heuristic methodologies will directly impact the following aspects. + +- a) High power consumptions in both network and UEs leading increased network CAPX and reduced UE battery life respectively and +- b) Degraded utilization of time-frequency resources affecting e2e spectral efficiency of the system. + +Issue is compounded by increase in IA latency and non-satisfactory reactive tracking performance KPI reports due to non-optimal configuration setting of large number of parameters available for SS bursts and CSI-RS TRS configuration supported in NR. UE could observe degraded tracking performances (and related other network KPIs) without appropriate CSI-RS planning. These are important network design aspects for massive MIMO systems with large carrier bandwidth and systems with carrier aggregation support where multiple BWPs are active with multiple time-frequency resource allocations for IA and TA reference signal transmissions. Typically, operators rely on skilled in the art manpower to suggest network wide configuration set which is prone to be sub-optimal. In addition to the demography, time dependent network usage patterns have strong influence on designing optimal configuration sets which can lead to spectral and power efficient network design. + +We propose AI/ML assisted network-wide (multi-gNB/TRP) optimization framework wherein AI/ML agent/engine can infer optimal SS Burst Set, CSI-RS TRS configurations per gNB/TRP based on multiple time, location, and usage + +dependent observations which are already available at different nodes of the NR access and core network elements {E2 Nodes (O-DUs, O-CUs), O-RU, SMO}. Optimizer capability can be extended to derive configurations other reference signals configurations including UE specific CSI-RS acquisition, and DMRS as well with additional observations or training data for the AI/ML agent/engine. Joint optimizations are also definite possibility which can be considered as extension of the use cases mentioned in this document. One example is jointly optimizing SSB and CSI-RS for faster beam acquisition operation in mmWave FR2 system. + +At high-level goal of this class of optimization problem (involving SS Burst Set, CSI-RS, and DMRS) is to minimize reference signal transmissions based on 3GPP supported configuration/reconfigurations options available subject to constraints given below (not an exhaustive list): + +- a) Target KPIs (like IA latency, TA estimation accuracy, reactiveness, channel estimation accuracy etc.) within the working limit suggested by the operator. +- b) Mobility and HO KPIs targets (operator inputs) which could be different in different parts of the network. +- c) Enable faster/reduced set beam search in connected mode improving RLF performance. +- d) Optimal CSI-RS and DMRS density for target parameter estimation accuracy (e.g., Mean Square Error metric). + +In the architecture/deployment options section, SS Burst Set optimization is used for Non-RT RIC framework and Near-RT RIC deployment framework is used for CSI-RS and DMRS configuration optimizations. + +### 3.4.2 Architecture/Deployment Options + +#### 3.4.2.1 Option 1a: Non-RT RIC Based Training and Deployment (SS Burst Set Configuration Optimization) + +In this class of architecture/deployment option, raw training data gathering, pre-processing them to generate AI/ML model training data, offline AI/ML model training and deployment are performed in the SMO/Non-Real Time RIC entity. Raw training data set are collected from the TRP/gNB or cluster of deployed TRP/gNBs which constitute the large-scale network deployment. By default, heterogeneous deployment is assumed supporting various slow time varying usage patterns in different parts of the network. + +Offline trained AI/ML agent/engine will allow operator to deploy it in Non-RT-RIC (if necessary, in Near-Real Time RIC). AI/ML Agents can derive optimal per gNB/TRP configurations statically or semi-statically triggered by operator requirements or KPIs observations from the NR E2 nodes. It is expected that AI/ML engine/agent will generate same/similar inferences for a set of gNB/TRPs which are deployed at the same geographical neighbours having similar usage pattern (example set of gNB/TRPs deployed to support a busy street with moderate mobility). + +SMO needs to collect required observations sets over different observation time windows to generate required training data set which necessitates O1, E2 and FH interface capability enhancements. Interface capabilities can be made scalable future requirements to support any additional observations required over O1 and E2 interfaces which can help in faster convergence of AI/ML agent/engine. + +``` + +1 @startuml +2 skinparam defaultFontSize 12 +3 +4 Box "Personnel" #lightblue +5 Actor "Operator" as OPERATOR +6 End box +7 +8 Box "Service Management and Orchestration" #gold +9 Participant "Data Collection and Control & Non-RT RIC" as SMO +10 Participant "rAPP" as NRTRIC +11 End box +12 +13 Box "O-RAN Nodes" #lightpink +14 Participant "E2-Nodes(O-CUs & O-DUs)" as E2NODES +15 Participant "O-RUs" as ORUs +16 End box +17 +18 group Data Collection and Pre-Processing +19 ORUs -> E2NODES : <> Observation, Masurement Data Collection +20 E2NODES -> SMO : <> Observation, Masurement Collection +21 OPERATOR -> SMO : Performance KPI Targets Inputs +22 SMO -> SMO : Data Pre-Processing and AI/ML Training Data Generation +23 +24 end +25 +26 group AI/ML Engine/Agent Training +27 SMO -> SMO : AI/ML Engine/Agent Training +28 end +29 +30 group Model Deployment and Inference Generation +31 group Operator-Initiated +32 SMO -> NRTRIC : <> Model Deployment +33 OPERATOR -> SMO : KPI Targets/Deployment Updates +34 SMO -> NRTRIC : <> Model Data +35 end +36 group System Initiated +37 SMO -> NRTRIC : <> PI Degradation & Alarms +38 end +39 SMO -> E2NODES : <> Measurement, Report Configuration +40 E2NODES -> SMO : <> Observation, Masurement Collection +41 SMO -> NRTRIC : <> Model Data +42 NRTRIC -> NRTRIC : AI/ML Agent/Engine Inference +43 NRTRIC -> SMO : <> Updated Optimal Configs +44 SMO -> E2NODES : <>Updated E2 Nodes Configurations +45 E2NODES -> ORUs : <> Updated O-RU Configurations +46 +47 end +48 +49 group ML Agent Performance Monitoring +50 ORUs -> E2NODES : <> Data Collection +51 E2NODES -> SMO : KPIs, Measurment Report, Observations +52 SMO -> SMO : Performance Evaluation & Fallback Config Decision +53 SMO -> E2NODES : <> Default/Fallback mMIMO Configuration +54 E2NODES -> SMO : <> Observation, Masurement Collection +55 SMO -> SMO : AI/ML Agent/Engine Re-Training Trigger +56 end +57 +58 @enduml + +``` + +![Flow diagram for SS Burst Set Configuration Optimization. The diagram shows interactions between Personnel (Operator), Service Management and Orchestration (Data Collection and Control & Non-RT RIC, rAPP), and O-RAN Nodes (E2-Nodes(O-CUs & O-DUs), O-RUs). The process is divided into three main phases: Data Collection and Pre-Processing, Model Deployment and Inference Generation, and ML Agent Performance Monitoring. Data Collection and Pre-Processing involves Performance KPI Targets Inputs, Data Pre-Processing and AI/ML Training Data Generation, and AI/ML Engine/Agent Training. Model Deployment and Inference Generation includes Operator-Initiated (KPI Targets/Deployment Updates, Model Deployment, Model Data) and System Initiated (PI Degradation & Alarms, Measurement, Report Configuration, Observation, Model Data, Updated Optimal Configs, Updated E2 Nodes Configurations, Updated O-RU Configurations). ML Agent Performance Monitoring involves KPIs, Measurement Report, Observations, Performance Evaluation & Fallback Config Decision, Default/Fallback mMIMO Configuration, Observation, AI/ML Agent/Engine Re-Training Trigger, and Data Collection.](73b0081bfd137e23536e275c5cb3dbd3_img.jpg) + +**Personnel** + +Operator + +**Service Management and Orchestration** + +Data Collection and Control & Non-RT RIC + +rAPP + +**O-RAN Nodes** + +E2-Nodes(O-CUs & O-DUs) + +O-RUs + +**Data Collection and Pre-Processing** + +Performance KPI Targets Inputs + +Data Pre-Processing and AI/ML Training Data Generation + +AI/ML Engine/Agent Training + +AI/ML Engine/Agent Training + +**Model Deployment and Inference Generation** + +**Operator-Initiated** + +KPI Targets/Deployment Updates + +Model Deployment + +Model Data + +**System Initiated** + +PI Degradation & Alarms + +Measurement, Report Configuration + +Observation, Measurement Collection + +Model Data + +AI/ML Agent/Engine Inference + +Updated Optimal Configs + +Updated E2 Nodes Configurations + +Updated O-RU Configurations + +**ML Agent Performance Monitoring** + +KPIs, Measurement Report, Observations + +Performance Evaluation & Fallback Config Decision + +Default/Fallback mMIMO Configuration + +Observation, Measurement Collection + +AI/ML Agent/Engine Re-Training Trigger + +Data Collection + +Flow diagram for SS Burst Set Configuration Optimization. The diagram shows interactions between Personnel (Operator), Service Management and Orchestration (Data Collection and Control & Non-RT RIC, rAPP), and O-RAN Nodes (E2-Nodes(O-CUs & O-DUs), O-RUs). The process is divided into three main phases: Data Collection and Pre-Processing, Model Deployment and Inference Generation, and ML Agent Performance Monitoring. Data Collection and Pre-Processing involves Performance KPI Targets Inputs, Data Pre-Processing and AI/ML Training Data Generation, and AI/ML Engine/Agent Training. Model Deployment and Inference Generation includes Operator-Initiated (KPI Targets/Deployment Updates, Model Deployment, Model Data) and System Initiated (PI Degradation & Alarms, Measurement, Report Configuration, Observation, Model Data, Updated Optimal Configs, Updated E2 Nodes Configurations, Updated O-RU Configurations). ML Agent Performance Monitoring involves KPIs, Measurement Report, Observations, Performance Evaluation & Fallback Config Decision, Default/Fallback mMIMO Configuration, Observation, AI/ML Agent/Engine Re-Training Trigger, and Data Collection. + +Figure 3.4.2.1-1. Flow diagram for SS Burst Set Configuration Optimization + +##### Requirements for SS Burst Set Configuration Optimization + +##### Required Observations for Training Data Set Generation + +Initialization: + +| Input/Output Data | | | | | | +|---------------------|-------------------------|-----------------------------------------------------------------|--------------|-------------------------------|---------------------------------------------| +| Interface | Source → Target | Name/Description | Units | Reporting Period, granularity | New or existing config | +| O1 via SMO | O-DU → Non-RT RIC | Supported SSB and CSI-RS TRS configurations per cell | - | Initialization | 3GPP TS38.331 | +| M-Plane via SMO | O-RU → Non-RT RIC | Supported common beam configuration from O-RU per cell | File | Initialization | Existing O-RAN.WG5.MP Chapter 8 | +| Open FH M-Plane | O-RU → O-DU | Beamforming weights or attributes via YANG module per cell | values in IE | Initialization | O-RAN.WG4.MP Section 12.4.2 | +| Open FH M-Plane | SMO → O-RU; O-DU → O-RU | Inferred SSB beam configuration in specified file per cell | file | Initialization | O-RAN.WG4.MP Section 12.4.2 | +| Open FH CUS-Plane | O-DU → O-RU | SSB beam attributes per cell | values in IE | Initialization | O-RAN-WG4.CUS Section 5.4.2 | +| Operator I/F to SMO | SMO → Non-RT RIC | Maximum Initial Access Latency for given SSB Beam Configuration | ms | Initialization | KPI metric input by the operator
New KPI | + +**Table 3.4.2.1-1.** + +Measurements/reports from E2 Nodes over O1 interface (AI/ML model training phase): + +| Input Data | | | | | | +|------------|-------------------|-------------------------------------------------------|-------|---------------------------------------------------------|---------------------------------------------------------------| +| Interface | Source → Target | Name/Description | Units | Reporting Period, granularity | New or existing measurement, Existing Specification (Section) | +| O1 via SMO | O-DU → Non-RT RIC | SS reference signal received power (SS-RSRP) per UE | dBm | (non real-time, reported every $T_{Win}$ * time window) | 3GPP TS 38.215 (Sec. 5.1.1)
New reporting | +| O1 via SMO | O-DU → Non-RT RIC | CSI reference signal received power (CSI-RSRP) per UE | dBm | (non real-time, reported every $T_{Win}$ * time window) | 3GPP TS 38.215 (Sec. 5.1.25)
New reporting | + +| | | | | | | +|------------|-------------------|----------------------------------------------------------------------------------------------|------------------|-----------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------| +| O1 via SMO | O-DU → Non-RT RIC | UL SRS RSRP measurement per UE | dBm | (non real-time, reported every $T_{Win}$ * time window) | 3GPP TS 38.215 (Sec. 5.2.5)
New reporting | +| O1 via SMO | O-CU → Non-RT RIC | Number of active UEs in NG-RAN (Number of RRC_CONNECTED UEs) per cell | Integer | (non real-time, measured and reported every $T_{Win}$ * time window) | 3GPP TS28.552
Sections: 5.1.1.23 & A.60
3GPP TS28.552 A.7 | +| O1 via SMO | O-CU → Non-RT RIC | Cell Specific Offsets (HO) defined within measObjectNR per neighbor cell | dB | (non real-time, reported every $T_{Win}$ * time window) | 3GPP TS 28.331 (Sec. 5.3.4)
New Reporting | +| O1 via SMO | O-DU → Non-RT RIC | PRACH correlation power for every received PRACH corresponding to each active SSB Beam Index | dBm | Non real-time, for every SSB Beam Index reported in $T_{Win}$ * time window | New Measurement (Could be derived measurement at O-DU (derived based on the existing RA-report defined in RAN2, can be standardized in SA5)
New Reporting | +| O1 via SMO | O-DU → Non-RT RIC | Received PRACH instance number and corresponding receive beam index | Integer | Non real-time, for every SSB Beam Index reported in $T_{Win}$ * time window | 3GPP TS 28.552-h40, subclause 5.1.1.20/ TS 38.314-g40, subclause 4.2.1.1
New Reporting | +| O1 via SMO | O-CU → Non-RT RIC | Network accessibility KPI per cell | Integer | Non real-time, reported every $T_{Win}$ * time window | 3GPP TS 28.554
Section 6.2 | +| O1 via SMO | O-CU → Non-RT RIC | DL/UL throughput/spectral efficiency per slice | Float (kbit/sec) | Non real-time, reported every $T_{Win}$ * time window | 3GPP TS 28.554
Section 6.3.2 and section 6.3.3 | + +Table 3.4.2.1-2. + +Measurements/reports from E2 Nodes (inference phase): + +| Input Data | | | | | | +|-------------------|------------------------|-------------------------------------------------------------------------------------------------|--------------|------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Interface | Source → Target | Name/Description | Units | Reporting Period, granularity | New or existing measurement,

Existing Specification

(Section)
| +| O1 via SMO | O-DU → Near-RT RIC | PRACH correlation power for every received PRACH corresponding to each active SSB Beam Index | dBm | Reported every $T_{Win-R}$ * time window | New Measurement (Could be derived measurement at O-DU (derived based on the existing RA-report defined in RAN2, can be standardized in SA5) New Reporting | +| O1 via SMO | O-DU → Near-RT RIC | Received PRACH instance number and corresponding beam index | Integer | Reported every $T_{Win-R}$ * time window | 3GPP TS 28.552-h40, subclause 5.1.1.20/ TS 38.314-g40, subclause 4.2.1.1 | +| O1 via SMO | O-CU → Non-RT RIC | Number of active UEs (mean, max) in NG-RAN (Number of RRC_CONNECTED UEs) per direction per cell | Integer | Reported every $T_{Win-R}$ * time window | 3GPP TS28.552 Sections 5.1.1.23 & A.60 | + +**Table 3.4.2.1-3.** + +$*T_{Win}$ is the predefined observation time window for offline training data collection. + +$*T_{Win-R}$ is the predefined observation widow during inference generation, typically $T_{Win-R} \leq T_{Win}$ + +In addition to these observations and KPIs, Data Collection and Control Unit is expected to have access to the cell site deployment, configuration information and site-specific information for example gNB/TRP density, terrain type. A set of predefined algorithmic steps will take these raw observations as inputs and generate required training data set in prescribed format for the AI/ML engine/agent. AI/ML model will generate optimal SS Burst Set configuration and associated CSI-RS configuration per gNB/TRP as inference. + +Output Signalling towards E2 Nodes: + +| Output Data | | | | | | +|--------------------|------------------------|---------------------------------------------------------------------------------------------------|--------------|------------------------------------|--------------------------------------------------| +| Interface | Source → Target | Name/Description | Units | Config. Period, granularity | New or existing config | +| O1 | SMO → O-DU | Inferred O-RU SS Burst Set (SS Block Number and SS Burst Periodicity and CSI-RS TRS Configuration | - | Initialization, per O-RU | 3GPP TS38.331

IE: ServingCellConfigCommon | + +**Table 3.4.2.1-4.** + +##### 3.4.2.1.1 O-RAN WG Impact Analysis + +This use case focuses on O1, M-Plane (via SMO) interfaces for observations, measurements, KPIs collection. O-RAN specified R1 interface is used as one of the options for trained AI/ML model deployment as rAPP in Non-Real Time RIC. Another possibility is both offline AI/ML model training and model deployment can be done in the rAPP. In this case R1 interface is also used to transport training data to rAPP. Inference is communicated to E2 nodes (O-CU/O-DU) using R1 APIs and O1 interface (via SMO). + +Impacts on O-RAN standards are identified below with the assumption that this is initial analysis report which is outcome of the massive MIMO pre-normative stage work. Captured impact analysis are based on latest published specifications of respective standards from identified O-RAN working groups. + +###### WG1 (use cases, architecture) Impact + +- a) O-RAN.WG1 - Use Cases Analysis Report + - o Based on the decision from pre-normative stage include this new use cases in the massive MIMO optimization UCTG document for Initial Access (SS Burst set configuration) configuration optimization problem. +- b) O-RAN.WG1- Use Cases Detailed Specification + - o Update use case specific details for Initial Access (SS Burst set configuration) massive-MIMO optimization considering pre-normative and normative stage decisions. + +###### WG2 (Non-RT RIC, R1) Impact + +- a) O-RAN.WG2 - Use Case Requirements + - o Based on the necessity add Initial Access (SS Burst) Massive-MIMO optimization use-case based on agreements from pre-normative phase. + - o No impact on A1 interface is identified + - AI/ML model training is done in SMO/Non-Real Time RIC and trained model deployment is done in Non-Real Time RIC as rAPP. + - Generated inference is communicated to E2 nodes (O-CU/O-DU) over O1 interface. +- b) O-RAN.WG2 - AIML + - o No impact identified + - This use case is expected to be in line with standardized AI/ML workflow. +- c) O-RAN.WG2 - Non-RT RIC Architecture & O-RAN.WG2 O-RAN Non-RT RIC: Functional Architecture + - o No impact identified for the Non-Real Time RIC architecture and functional architecture specifications + - o Incorporate the changes (if any) for R1 interface between the rAPPs and the non-RT RIC framework functions for following two rAPP deployment aspects. + - Case 1: When AI/ML model is offline trained in SMO and deployed in Non-Real Time RIC as rAPP: Mechanism to deploy the model as rAPP over R1, inference communication over R1 and finally over O1 interface to E2 nodes (O-CU/O-DU) + - Case 2: Alternatively, when AI/ML model is offline trained and deployed in the rAPP itself: Investigate AI/ML flow support for initial model load, training data transport to rAPP and inference communication to O1 via R1. + - Background information: + - SS Burst set configuration optimization AI/ML model is a micro service (rAPP) running in the Non-Real Time RIC. + - Non-Real Time RIC framework handles rAPP LCM. + - For model training data and inference communication from and to E2 nodes over O1 interface and M-plane interfaces are used. + - One of the feasible architectures is AI/ML model training in SMO or Non-Real Time RIC framework and trained AI/ML model deployment is done as rAPP. + - Alternative architecture for model training and deployment model is both are done in rAPP. R1 interface is used for model onboarding, training data set + +transport. Inference data communication via O1 interface within the current Near-RT RIC framework. + +###### WG3 (Near-RT RIC, E2) Impact + +- a) No impact identified + +###### WG4 (CUS, M-Plane) Impact + +- a) No impact identified + - o Background information: + - Over M-Plane interface SMO communicates/receives supported O-RU SSB beam configurations. + - These configurations are preprocessed with observations, measurements, KPIs data received over O1 interface to generate training data set which is used for offline AI/ML model training. + +###### WG5 (O1) Impact + +- a) O-RAN.WG5 - SMO - O-CU (O-RAN O1 Interface specification for O-CU-UP and O-CU-CP & O-RAN O1 Interface for O-CU-UP and O-CU-CP - YANG Models) ; SMO - O-DU (O-RAN O1 Interface specification for O-DU & O-RAN O1 Interface for O-DU 2.0 - YANG Models) + - o Enhance O1 data model yang definitions for new measurements/ observations reporting required for SS Burst Set configuration optimization use case. + - Data models/structures required for new measurement reports to the Non-Real Time RIC via SMO. Refer to the requirement section of this use case. + - L1/2 measurements: Analyse need for new data model definition over NETCONF for per cell or per UE measurement reporting (refer to requirement section for new reporting requirements). + - Counters: Add new data model to accommodate Number of active UEs in NG-RAN (Number of RRC\_CONNECTED UEs) over a predefined observation time window. + +Based on the current understanding most of the measurements are specified in the 3GPP specifications except few like PRACH power measurement, which can be possibly derived based on the existing RA-reports thus can be proposed to 3GPP for standardized in SA5. New reporting will have to be incorporated into the O1 interface standard in terms of addition of new yang data models. + +###### WG10 (O1) Impact + +- a) O-RAN.WG10 - O-RAN Operations and Maintenance Architecture & O-RAN Operations and Maintenance Interface Specifications + - o No impact identified on the OAM architecture + - o Impacts on the O1 interface to O-RAN elements are identified in WG5 + - Background information + - Include data model enhancements to the O1 interface definitions for new measurements, observations required for SS Burst Set configuration optimization use case. + +###### **O-RAN Standard Impact Summary:** + +Impacts on O-RAN WGs is identified in the following areas: + +- Introduce a set of new measurements/observations and reporting at O-DU and/or O-CU which are not defined in O-RAN specification already. New measurement/reporting are indicated in the requirement section of the use case. +- Incorporate changes in R1 interface specification for the case when model onboarding and training of AI/ML model is done in the rAPP microservice and, +- Implement potential changes to the O1 interfaces assuming other required KPIs are specified in 3GPP or O-RAN standards. + +##### 3.4.2.1.2 Relation and Impact on 3GPP Specification + +UE- Specific Measurements and Reporting - From the requirement section, per UE specific measurements reporting which should be introduced in the upcoming release (e.g., RAN2 MDT trace specification, 3GPP TS 28.552 and related standards). We also propose that these new measurements should be taken up in the upcoming 3GPP RAN1 AI/ML discussion. + +PRACH power measurement be derived based on the existing RA-report defined in RAN2, thus can be proposed to 3GPP for standardized in SA5. + +New KPI - New KPI definition in 3GPP (e.g., Initial access latency value in case of SS Burst Set configuration optimization use case) need to be included in the future releases of 3GPP TS 32.425 Performance Management (PM); Performance measurements E-UTRAN specification. + +Thus, during the normative work phase, changes for the R1 and O1 interface need to be worked out with respective WGs. Similarly, for any 3GPP specification dependencies, appropriate steps should be taken based on the agreed O-RAN MVP-C Massive MIMO Optimization normative stage discussions points. + +#### 3.4.2.2 Option 2a: Non-RT RIC Based Training and Near-RT RIC Deployment (DMRS and CSI-RS Configuration Optimizations) + +For the class of use cases where few TTI level reaction time is necessary (example use cases are configuration optimization for CSI-RS ports allocation for acquisition in DL and UL, UE specific DMRS allocation in DL or UL etc.), offline trained AI/ML model need to be deployed in Near Real-Time RIC. In this architecture/deployment option, raw training data gathering, pre-processing them to generate AI/ML model training data set, and offline AI/ML model training are performed in the Data collection and control/Non-Real Time RIC entity and trained model deployment happens in Near-RT RIC. Raw training data set are collected from the TRP/gNB or cluster of deployed TRP/gNBs which constitute the large-scale network deployment. By default, heterogeneous network deployment is assumed supporting various usage patterns in different parts of the network. + +Offline trained AI/ML agent/engine will allow operator to deploy it in Near-RT-RIC over O1 interface. AI/ML Agents can derive optimal per gNB/TRP configurations statically or semi-statically triggered by operator requirements or KPIs observations, measurements from E2 nodes. It is expected that AI/ML engine/agent will generate same/similar inferences for a set of gNB/TRPs which are deployed at the same geographical neighbours having similar usage pattern (example set of gNB/TRPs deployed to support a busy street with low to moderate mobility). + +Data Collection and Control Unit collects required observations sets over different observation time windows to generate required training data set which necessitates O1, E2, and FH interface capability enhancements. Interface capabilities can be made scalable for future requirements to support any additional observations required over O1 and E2 interfaces which can help in faster convergence of AI/ML agent/engine. + +``` + +1 @startuml +2 skinparam defaultFontSize 12 +3 +4 Box "Personnel" #lightblue +5 Actor "Operator" as OPERATOR +6 End box +7 +8 Box "Service Management and Orchestration" #gold +9 Participant "Data Collection and Control" as SMO +10 Participant "Non-RT RIC" as NRTRIC +11 End box +12 +13 Box "O-RAN Nodes" #lightpink +14 Participant "Near-RT RIC" as RTRIC +15 Participant "E2-Nodes" as E2NODES +16 Participant "O-RUs" as ORUs +17 End box +18 +19 group Data Collection and Pre-Processing +20 ORUs -> E2NODES : <> Observation, Measurement Data Collection +21 E2NODES -> SMO : <> Observation, Measurement Collection +22 OPERATOR -> SMO : Performance KPI Targets +23 Inputs +24 SMO -> SMO : Data Pre-Processing and AI/ML Training Data Generation +25 +26 end +27 +28 group ML Engine/Agent Training +29 SMO -> NRTRIC : AI/ML Training Data +30 NRTRIC -> NRTRIC : AI/ML Engine/Agent Training +31 end +32 +33 group Model Deployment and Inference Generation +34 group Operator-Initiated +35 OPERATOR -> RTRIC : KPI Targets/Deployment Updates +36 end +37 group System Initiated +38 SMO -> RTRIC : <> PI Degradation & Alarms +39 end +40 NRTRIC -> RTRIC : <> Model Deployment +41 SMO -> E2NODES : <> Measurement and Report Configuration +42 SMO -> RTRIC : <> Training Data (Optional) +43 E2NODES -> RTRIC : <> Measure Reports Collection +44 RTRIC -> RTRIC : AI/ML Agent/Engine Inference +45 RTRIC -> E2NODES : <> Updated Optimal Configs (E2 Nodes and O-RU Configurations) +46 E2NODES -> ORUs : <> Updated O-RU Configurations +47 +48 end +49 +50 group ML Agent Performance Monitoring +51 E2NODES -> SMO : KPIs, Measurement Report, Observations +52 RTRIC -> SMO : <> ML Performance Feedback +53 ORUs -> E2NODES : <> Data Collection +54 SMO -> SMO : Performance Evaluation & Fallback Config Decision +55 SMO -> E2NODES : <> Default/Fallback mMIMO Configuration +56 E2NODES -> SMO : <> Observation, Measurement Collection +57 +58 SMO -> NRTRIC : AI/ML Agent/Engine Re-Training Trigger +59 end +60 +61 @enduml + +``` + +![Flow diagram for CSI-RS and DMRS Configuration Optimization. The diagram shows the interaction between Personnel (Operator), Service Management and Orchestration (Data Collection and Control, Non-RT RIC), and O-RAN Nodes (Near-RT RIC, E2-Nodes, O-RUs). The process is divided into three main phases: 1. Data Collection and Pre-Processing, 2. ML Engine/Agent Training, and 3. Model Deployment and Inference Generation. Key messages include: <> Observation, Measurement Collection; <> Observation, Measurement Data Collection; Performance KPI Targets Inputs; Data Pre-Processing and AI/ML Training Data Generation; AI/ML Training Data; AI/ML Engine/Agent Training; KPI Targets/Deployment Updates; <> PI Degradation & Alarms; <> Model Deployment; <> Measurement and Report Configuration; <> Training Data (Optional); <> Measure Reports Collection; AI/ML Agent/Engine Inference; <> Updated Optimal Configs (E2 Nodes and O-RU Configurations); <> Updated O-RU Configurations; KPIs, Measurement Report, Observations; <> ML Performance Feedback; Performance Evaluation & Fallback Config Decision; <> Default/Fallback mMIMO Configuration; <> Observation, Measurement Collection; AI/ML Agent/Engine Re-Training Trigger; <> Data Collection.](0ecd0dd8bd3f423b855f4b5cbe175ad2_img.jpg) + +Flow diagram for CSI-RS and DMRS Configuration Optimization. The diagram shows the interaction between Personnel (Operator), Service Management and Orchestration (Data Collection and Control, Non-RT RIC), and O-RAN Nodes (Near-RT RIC, E2-Nodes, O-RUs). The process is divided into three main phases: 1. Data Collection and Pre-Processing, 2. ML Engine/Agent Training, and 3. Model Deployment and Inference Generation. Key messages include: <> Observation, Measurement Collection; <> Observation, Measurement Data Collection; Performance KPI Targets Inputs; Data Pre-Processing and AI/ML Training Data Generation; AI/ML Training Data; AI/ML Engine/Agent Training; KPI Targets/Deployment Updates; <> PI Degradation & Alarms; <> Model Deployment; <> Measurement and Report Configuration; <> Training Data (Optional); <> Measure Reports Collection; AI/ML Agent/Engine Inference; <> Updated Optimal Configs (E2 Nodes and O-RU Configurations); <> Updated O-RU Configurations; KPIs, Measurement Report, Observations; <> ML Performance Feedback; Performance Evaluation & Fallback Config Decision; <> Default/Fallback mMIMO Configuration; <> Observation, Measurement Collection; AI/ML Agent/Engine Re-Training Trigger; <> Data Collection. + +Figure 3.4.2.2-1. Flow diagram for CSI-RS and DMRS Configuration Optimization + +##### Requirements for CSI-RS and DMRS Configuration Optimization + +###### a) DMRS Configuration Optimization: Required Observations for Training Data Set Generation + +Initialization: + +| Input/Output Data | | | | | | +|----------------------|-------------------|----------------------------------------------------------------------------------------------------------------------------|-------|-----------------------------|------------------------| +| Interface | Source Target | Name/Description | Units | Config. Period, granularity | New or existing config | +| O1 Interface via SMO | O-DU → Non-RT RIC | Supported DMRS configuration per cell (example for PDSCH, IE DMRS-DownlinkConfig, for PUSCH IE DMRS-UplinkConfig) per cell | - | Initialization | 3GPP TS 38.331 | +| O1 Interface via SMO | O-DU → Non-RT RIC | Supported SRS configuration per cell (SRS-Config IE) per cell | - | Initialization | 3GPP TS 38.331 | + +Table 3.4.2.2-1. + +1 Measurements/reports from E2 Nodes over O1 interface (AI/ML model training phase): + +| Input Data | | | | | | +|------------|-------------------|-------------------------------------------------------------------------------------|------------------|---------------------------------------------------------|---------------------------------------------------------------| +| Interface | Source Target → | Name/Description | Units | Reporting Period, granularity | New or existing measurement, Existing Specification (Section) | +| O1 via SMO | O-DU → Non-RT RIC | SRS reference signal received power (SRS-RSRP) per UE | dBm | (non real-time for model training) | 3GPP TS 38.215 (Sec. 5.1.19)
New reporting | +| O1 via SMO | O-DU → Non-RT RIC | gNB Rx – Tx time difference (SRS based) per UE | Sec | (non-real time, for model training) | 3GPP TS 38.215 (Sec. 5.2.3)
New reporting | +| O1 via SMO | O-DU → Non-RT RIC | DMRS based SNR measurement at O-DU per UE | dB | (non-real time, for model training) | New measurement and reporting | +| O1 via SMO | O-DU → Non-RT RIC | CSI reference signal received power (CSI-RSRP) per UE | dBm | (non real-time for model training) | 3GPP TS 38.215 (Sec. 5.1.2)
New reporting | +| O1 via SMO | O-CU → Non-RT RIC | Number of active UEs in NG-RAN (Number of RRC_CONNECTED UEs) per direction per cell | Integer | (non real-time, measured every $T_{Win}$ * time window) | 3GPP TS28.552 Sections: 5.1.1.23 & A.60
3GPP TS28.552 A.7 | +| O1 via SMO | O-CU → Non-RT RIC | Network accessibility KPI per cell | Integer | (non real-time, measured every $T_{Win}$ * time window) | 3GPP TS 28.554 Section 6.2 | +| O1 via SMO | O-CU → Non-RT RIC | DL/UL network throughput per slice | Float (kbit/sec) | (non real-time, measured every $T_{Win}$ * time window) | 3GPP TS 28.554 Section 6.3.2 and section 6.3.3 | +| O1 via SMO | O-DU → Non-RT RIC | DMRS/SRS based Doppler estimate per UE | Hz | (non real-time, measured every $T_{Win}$ * time window) | New measurement and reporting | + +2 Table 3.4.2.2-2. + +3 + +1 Measurements/reports from E2 Nodes (inference phase): + +| Input Data | | | | | | +|------------|--------------------|-------------------------------------------------------------------------------------------------|---------|-----------------------------------------------------|---------------------------------------------------------------| +| Interface | Source Target → | Name/Description | Units | Reporting Period, granularity | New or existing measurement, Existing Specification (Section) | +| E2 | O-DU → Near-RT RIC | DMRS/SRS Doppler Estimate per UE | Hz | every $T_{Win-R}$ *
time window | New measurement and reporting | +| E2 | O-CU → Near-RT RIC | Number of active UEs (mean, max) in NG-RAN (Number of RRC_CONNECTED UEs) per direction per cell | Integer | Reported every $T_{Win-R}$ *
time window | 3GPP TS28.552 Sections 5.1.1.23 & A.60
3GPP TS28.552 A.7 | +| E2 | O-DU → Near-RT RIC | DMRS based SNR measurement at O-DU per UE | dB | every $T_{Win-R}$ *
time window | New Measurement and reporting | +| E2 | O-DU → Near-RT RIC | SRS reference signal received power (SRS-RSRP) per UE | dBm | every SRS occasion and averaged over $K$ receptions | 3GPP TS 38.215 (Sec. 5.1.19)
New reporting | + +2 Table 3.4.2.2-3. + +3 +4 Output Signalling towards E2 Nodes: + +| Output Data | | | | | | +|-------------|--------------------|------------------------------------------------------------------------------------------------------------------|-------|----------------------------------|------------------------| +| Interface | Source Target → | Name/Description | Units | Config. Period, granularity | New or existing config | +| E2 | Near-RT RIC → O-DU | DMRS configuration per cell (example for PDSCH, IE DMRS-DownlinkConfig, for PUSCH IE DMRS-UplinkConfig) per cell | Index | Configured every $T > T_{Win-R}$ | 3GPP TS 38.331 | + +5 Table 3.4.2.2-4. + +6 $*T_{Win}$ is the predefined observation time window for offline training data collection. + +7 $*T_{Win-R}$ is the predefined observation widow during inference generation, typically $T_{Win-R} \leq T_{Win}$ + +###### **(b) CSI-RS Configuration Optimization:** Required Observations for Training Data Set Generation + +Initialization: + +| Input/Output Data | | | | | | | +|----------------------------|-----------------------|---|-----------------------------------------|-------|-----------------------------------|-----------------------------| +| Interface | Source
Target | → | Name/Description | Units | Config.
Period,
granularity | New or existing config | +| O1
Interface
via SMO | O-DU → Non-
RT RIC | | Supported CSI-RS configuration per cell | - | Initialization | TS 138 331
Section 6.3.2 | +| O1
Interface
via SMO | O-DU → Non-
RT RIC | | Supported SSB configuration per cell | - | Initialization | TS 138 331
Section 6.3.2 | + +**Table 3.4.2.2-5.** + +###### 1 Measurements/reports from E2 Nodes over O1 interface (AI/M model training phase): + +| Input Data | | | | | | +|-------------------|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------|------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Interface | Source → Target | Name/Description | Units | Reporting Period, granularity | New or existing measurement, Existing Specification (Section) | +| O1 via SMO | O-DU → Non-RT RIC | SS reference signal received power (SS-RSRP) per UE | dBm | (non real-time for model training) | 3GPP TS 38.215 (Sec. 5.1.1)
New reporting | +| O1 via SMO | O-DU → Non-RT RIC | CSI reference signal received power (CSI-RSRP) per UE | dBm | (non real-time for model training) | 3GPP TS 38.215 (Sec. 5.1.2)
New reporting | +| O1 via SMO | O-DU → Non-RT RIC | CSI Reports UE specific Channel Quality Index (CQI), Precoding matrix indicator (PMI), Rank Indicator (RI) per UE | CSI Report | (non-real time collection for model training) | 3GPP TS 38.214 (Sec. 5.2.2)
New reporting | +| O1 via SMO | O-DU → Non-RT RIC | PRACH correlation power for every received PRACH corresponding to each active SSB Beam Index | dBm | (non real-time collection for model training) | New Measurement (Could be derived measurement at O-DU (derived based on the existing RA-report defined in RAN2, can be standardized in SA5)
New Reporting | +| O1 via SMO | O-DU → Non-RT RIC | Received PRACH instance number and corresponding beam index | Integer | Non real-time, for every SSB Beam Index within $T_{Win} *$ time window | 3GPP TS 28.552-h40, subclause 5.1.1.20/ TS 38.314-g40, subclause 4.2.1.1 | +| O1 via SMO | O-CU → Non-RT RIC | Number of active UEs (mean, max) in NG-RAN (Number of RRC_CONNECTED UEs) per direction per cell | Integer | Reported every $T_{Win-R} *$ time window | 3GPP TS28.552 Sections 5.1.1.23 & A.60
3GPP TS28.552 A.7 | +| O1 via SMO | O-CU → Non-RT RIC | Beam acquisition time per UE: UE reports beam measurement through CSI reports. gNB prepares an average beam acquisition time metric based on the per UE CSI reports in stages P2/P3 | msec | (non real-time, measured every $T_{Win} *$ time window | New Measurement & Report | +| O1 via SMO | O-CU → Non-RT RIC | DL/UL throughput per direction per cell

Spectral efficiency can be computed from the throughput. | Float (kbit/sec) | (non real-time, measured every $T_{Win} *$ time window | 3GPP TS 28.554 Section 6.3.2 and section 6.3.3 | + +**Table 3.4.2.2-6.** + +1 Measurements/reports from E2 Nodes (inference phase): + +| Input Data | | | | | | +|------------|--------------------|-------------------------------------------------------------------------------------------------------|--------------|---------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Interface | Source Target → | Name/Description | Units | Reporting Period, granularity | New or existing measurement, Existing Specification (Section) | +| E2 | O-DU → Near-RT RIC | SS reference signal received power (SS-RSRP) per UE | dBm | Measured every $T_{Win-R}$ *
time window | 3GPP TS 38.215 (Sec. 5.1.1)
New reporting | +| E2 | O-DU → Near-RT RIC | CSI reference signal received power (CSI-RSRP) per UE | dBm | Measured every $T_{Win-R}$ *
time window | 3GPP TS 38.215 (Sec. 5.1.2)
New reporting | +| E2 | O-DU → Near-RT RIC | UE Specific Channel Quality Index (CQI), Precoding matrix indicator (PMI), Rank Indicator (RI) per UE | Index/Number | Measured every $T_{Win-R}$ *
time window | 3GPP TS 38.214 (Sec. 5.2.2)
New reporting | +| E2 | O-DU → Near-RT RIC | PRACH correlation power for every received PRACH corresponding to each active SSB Beam Index | dBm | Measured every $T_{Win-R}$ *
time window | New Measurement (Could be derived measurement at O-DU (derived based on the existing RA-report defined in RAN2, can be standardized in SA5)
New Reporting | + +2 **Table 3.4.2.2-7.** + +3 $*T_{Win}$ is the predefined observation time window for offline training data set collection. + +4 $*T_{Win-R}$ is the predefined observation widow during inference generation, typically $T_{Win-R} \leq T_{Win}$ + +5 +6 For both DMRS and CSI-RS optimizations, in addition to the above measurements, observations and KPIs, Data +7 Collection and Control module is expected to have access to the cell site deployment- configuration information and site- +8 specific information for example gNB/TRP density, terrain type. A set of predefined algorithmic steps will take these raw +9 observations as inputs and generate required training data set in prescribed format for the AI/ML engine/agent. AI/ML +10 model will generate optimal SS Burst Set configuration and associated CSI-RS configuration per gNB/TRP as inference. + +Output Signalling towards E2 Nodes: + +| Output Data | | | | | | +|-------------|--------------------|-------------------------------------------------------------|-------|-----------------------------|-----------------------------| +| Interface | Source Target | Name/Description | Units | Config. Period, granularity | New or existing config | +| E2 | Near-RT RIC → O-DU | Inferred CSI-RS configuration and related SSB configuration | Index | Non-real time per gNB | TS 138 331
Section 6.3.2 | + +Table 3.4.2.2-8. + +##### 3.4.2.2.1 O-RAN WG Impact Analysis + +This set of use case focus is on O1, M-Plane (via SMO) interfaces for observations, measurements, KPIs collection. O-RAN specified O1 interface is used for trained AI/ML model deployment as xAPP in Near-Real Time RIC. Inference is communicated to E2 nodes (O-CU/O-DU) using E2 interface. Impacts on O-RAN standards are identified below with the assumption that this is initial analysis report which is outcome of the massive MIMO pre-normative stage work. Captured impact analysis are based on latest published specifications of respective standards from the identified O-RAN working groups. + +###### WG1 (use cases, architecture) Impact + +- a) O-RAN.WG1.Use Cases Analysis Report + - o Update the use case Massive MIMO Optimization - Non-Real Time RIC Training and Near Real Time RIC Deployment (CSI-RS and DMRS Configuration Optimization) considering pre-normative and normative stage decisions. +- b) O-RAN.WG1.Use Cases Detailed Specification + - o Update the use case details for Massive MIMO Optimization Non-Real Time RIC Training and Near Real Time RIC Deployment (CSI-RS and DMRS Configuration Optimization) considering pre-normative and normative stage decisions. + +###### WG2 (Non-RT RIC, R1, A1) Impact + +- c) O-RAN.WG2 - Use Case Requirements + - o Add sub-use case details for the Non-Real Time RIC Training and Near Real Time RIC Deployment (CSI-RS and DMRS Configuration Optimization) considering pre-normative and normative stage decisions. +- d) O-RAN.WG2 - AIML + - o No impact identified + - This use case is expected to be in line with standardized AI/ML workflow. +- e) O-RAN.WG2 - Non-RT RIC Architecture & O-RAN.WG2 - Non-RT RIC ARCH TR + - o No impact identified for the Non-Real Time RIC architecture + - o Background information: + - CSI-RS and DMRS configuration optimization is an xAPP running in the Near-Real Time RIC after training in Non-Real Time RIC + - Near-Real Time RIC framework handles xAPP LCM. + - For model training data and inference communication from and to E2 nodes over O1 interface (via SMO) and M-plane interfaces are used. +- f) A1 Interface + - o No impact identified + +###### WG3 (Near-RT RIC, E2) Impact + +- g) O-RAN.WG3- Use Case and Requirements + - o Add use case details for Non-RT RIC Training and Near RT RIC Deployment (CSI-RS and DMRS Configuration Optimization) considering agreements from pre-normative and normative phase approvals +- h) O-RAN.WG3. Near-RT RAN Intelligent Controller Near-RT RIC Architecture + - o No impact identified + - o Background information + - For CSI-RS and DMRS optimizations, trained AI/ML model is deployed as xAPP which will interface with E2 nodes (O-CU/O-DU) using E2 interface. + - xAPP uses Near-Real Time RIC services and E2 interfaces to a) get measurements, observations, PIs from the E2 Nodes for inference generation and b) configures DMRS or CSI-RS in the E2 nodes. +- i) O-RAN.WG3- Near-Real-time RAN Intelligent Controller Architecture & E2 General Aspects and Principles + - o No impact identified + - o Background information + - Offline trained AI/ML model is deployed as xAPP which uses Near-Real Time RIC services and E2 interfaces to a) get measurements, observations, PIs from the E2 Nodes for inference generation and b) configures DMRS or CSI-RS in the E2 nodes. +- j) O-RAN.WG3- Near-Real-time RAN Intelligent Controller, E2 Application Protocol + - o Add new measurements and reporting to the E2 interface from E2 nodes (O-CU/O-DU) to Near-Real Time RIC during inference generation and subsequent inference communication to E2 nodes. + - o Background information + - DMRS/CSI-RS optimization xAPP uses E2 interface to a) get measurements, observations, KPIs from the E2 Nodes for inference generation and b) configures DMRS/CSI-RS in the E2 Nodes. +- k) O-RAN.WG3- Near-Real-time RAN Intelligent Controller E2 Service Model (KPM) + - o Enhance the interface for cell level KPM and other measurements used in CSI-RS and DMRS configuration optimization use cases during inference generation. +- l) O-RAN.WG3- Near-Real-time RAN Intelligent Controller E2 Service Model (Common, EC, NI) + - o Add new E2AP requirements for DMRS and CSI/RS + - o Identify definition of new E2SMs and required information models that may be required by for DMRS and CSI-RS configuration use cases and reflect them the next version of standard ORAN-WG3.E2SM. + - We also assuming all measurement are specified in 3GPP TS 28.552, 3GPP TS 28.554, 3GPP TS 38.215, 3GPP TS 38.214, TS 38 331, TS 37.320 and/or respective O-RAN standards + +###### WG5 (O1) Impact + +- m) O-RAN.WG5 - SMO - O-CU (O-RAN O1 Interface specification for O-CU-UP and O-CU-CP & O-RAN O1 Interface for O-CU-UP and O-CU-CP - YANG Models); SMO - O-DU (O-RAN O1 Interface specification for O-DU & O-RAN O1 Interface for O-DU 2.0 - YANG Models) + - o Enhance the yang data models due to new measurement/observations reporting listed for CSI-RS and DMRS configuration optimizations use cases requirement section + +Based on the requirement section most of the measurements are specified in the 3GPP specification except couple of them like PRACH power measurement, DMRS based SNR measurement, Doppler, Beam acquisition time measurement etc. which need to be proposed to 3GPP for standardized in SA5. New reporting will have new data model definition on the O1 interface standard in terms of addition of new yang data models. + +###### WG10 (SMO, O1) Impact + +- n) O-RAN.WG10 - O-RAN Operations and Maintenance Architecture & O-RAN Operations and Maintenance Interface Specifications + - o No impact identified + +###### Summary of O-RAN WG Impacts: + +Impacts on O-RAN WGs are identified in the following areas: + +- Introduce set of new UE/cell specific measurements/observations reporting at O-DU and/or O-CU which are not defined in O-RAN specification already as indicated in the requirement section of the respective use cases. +- Incorporate E2 interface specification improvements for new measurement data communication from E2 nodes to Near-Real Time RIC. Impacts described here is based on the assumption that required KPIs are specified in 3GPP or O-RAN standard. + +Work in O-RAN WGs can be minimized by referring to the ongoing 3GPP and O-RAN specification as done today, e.g., E2SM-KPM, O-RAN.WG5.O-CU-O1, O-RAN.WG10.O1. + +#### 3.4.2.2 Relation and Impact on 3GPP Specification + +UE- Specific Measurements and Reporting - From the requirement section, per UE measurements and reporting have to be added to the upcoming release (R17/18) of 3GPP standards (e.g., RAN2 MDT trace specification, 3GPP TS 28.552 and related standards). These new measurements will be also taken up in the upcoming AI/ML 3GPP RAN1 activities. + +PRACH power measurement be derived based on the existing RA-report defined in RAN2, thus can be proposed to 3GPP for standardized in SA5. + +#### 3.4.2.3 Options 1b, 2b: E2 Node (O-CU) based AI/ML inference (Optimization of SS Burst Set, DMRS and CSI-RS Configuration) + +In this architecture option, the AI/ML model training might also be hosted in Non-RT RIC in case of SS Burst Set and in Near-RT RIC in case of DM-RS and CSI-RS configuration, but with the difference that the AI/ML model is deployed in the O-CU where the inference is executed. In contrast to the Non-RT RIC-based deployment (option 1 - SS Burst Set configuration optimization) or Near-RT RIC based deployment (option 2 - DMRS/CSI-RS configuration optimization), this deployment scenario presents the opportunity for optimization with faster loop timing or in different deployment architectures. While a Non-/Near-RT RIC based solution might be preferable to coordinate across multiple gNBs, a O-CU based inference solution might be preferred for disaggregated deployments where an O-CU controls a large number of O-DUs. Similarly, Non-/Near-RT RIC based solutions (option 1 or 2) might be preferred for slow loop timings while a O-CU based solution might be preferred for fast loop timings. Besides this difference, the same principles as previously described apply and the same performance gain can be expected. + +The configuration is assumed to be a rather slow process for SS Burst Set reconfiguration. DM-RS and CSI-RS might be reconfigured more dynamically, but there are probably no additional performance gains of an O-CU based inference over a Near-RT RIC based inference. Nevertheless, the O1/E2 load to continuously transfer data for inference will be reduced and the algorithm might have access to a larger number of configuration parameters when hosted at the O-CU. + +Therefore, the operator can leverage on the non-real time data collection capabilities of the O1/E2 interface (for offline ML training) plus the computational capacity (AI/ML framework) of the RIC(s) for ML training but perform the ML inference in the E2 Node. More specifically, the alternative architecture for SS Burst Set configuration optimization hosts ML training in the Non-Real Time RIC and inference in the E2 Node (O-CU) (Option 1b in Figure 3.4.2.3-1. middle). The alternative architecture for DMRS and CSI-RS configuration optimization hosts ML training in the Near-Real Time RIC and inference in the E2 Node (O-CU) (Option 2b in Figure 3.4.2.3-1. right). + +ML Deployment Scenario 1.5 (Technical Report O-RAN.WG2.AI/ML-v01.03) supports training in the Non-RT RIC and inference in the E2 Node. Training in the Near-RT RIC and inference in the E2 Node is a new deployment scenario still to be added to respective specifications. Related impact on O-RAN WGs is analyzed in section 3.4.2.3.1. 3GPP RAN WGs will start working on gNB hosted AI/ML algorithms in 3GPP Rel.18. More details are provided in 3GPP TR 37.817. + +This O-RAN architecture option introduced in this section will complement the 3GPP AI/ML approach (i.e. model hosted in E2 Node) with RIC based training capabilities and the ability to deploy a trained ML model in the E2 node. + +In both cases of ML training in Non- or Near-RT RIC, the ML model will be deployed via the O1 interface. This means in case of ML training in the Near-RT RIC, the trained ML model will be delivered from Near-RT RIC to SMO via O1 first and from SMO to E2 Node via O1 next. This ensures a common ML model deployment in the E2 nodes centrally controlled via the SMO. ML model training in the Near-RT RIC might be preferred in cases where the ML training relies on extensive RAN data provided via E2, which may not necessarily be available via O1. While Non-RT RIC training might be preferred for network specific ML models, Near-RT RIC might be preferred for cell specific ML models. A retraining of an existing network specific ML model with cell specific data in the Near-RT RIC can also be envisioned. + +![Figure 3.4.2.3-1: O-RAN deployment options 1a, 1b, and 2b. Option 1a/2a shows ML Training and Inference in the Near-/Non-RT RIC, with data collection and policy configuration between the RIC and the E2 Node RAN function. Option 1b shows ML Training in the Non-RT RIC and ML Inference in the E2 Node RAN function, with ML Model deployment from the Non-RT RIC to the E2 Node. Option 2b shows ML Training in the Near-RT RIC and ML Inference in the E2 Node RAN function, with ML Model deployment from the Near-RT RIC to the E2 Node via the Non-RT RIC.](4f3dadd1e46ac63d5a74c959a0d79ecc_img.jpg) + +The diagram illustrates three O-RAN deployment options for ML training and inference across different RIC types and the E2 Node. + +- Option 1a/2a:** ML Training and ML Inference occur within the Near-/Non-RT RIC. Data collection and ML training/inference happen between the RIC and the E2 Node RAN function. Policy configuration is sent from the RIC to the E2 Node. +- Option 1b:** ML Training occurs in the Non-RT RIC, while ML Inference occurs in the E2 Node RAN function. The ML Model is deployed from the Non-RT RIC to the E2 Node. +- Option 2b:** ML Training occurs in the Near-RT RIC, while ML Inference occurs in the E2 Node RAN function. The ML Model is deployed from the Near-RT RIC to the E2 Node via the Non-RT RIC. + +Figure 3.4.2.3-1: O-RAN deployment options 1a, 1b, and 2b. Option 1a/2a shows ML Training and Inference in the Near-/Non-RT RIC, with data collection and policy configuration between the RIC and the E2 Node RAN function. Option 1b shows ML Training in the Non-RT RIC and ML Inference in the E2 Node RAN function, with ML Model deployment from the Non-RT RIC to the E2 Node. Option 2b shows ML Training in the Near-RT RIC and ML Inference in the E2 Node RAN function, with ML Model deployment from the Near-RT RIC to the E2 Node via the Non-RT RIC. + +**Figure 3.4.2.3-1. Left: O-RAN deployment options 1a and 2a. Middle, right: Deployment options 1b and 2b with ML inference in the RAN E2 Node.** + +##### 3.4.2.3.1 Additional O-RAN Standardization Impact + +###### WG2 (Non-RT RIC, A1, R1) Impact + +- O-RAN.WG2.AI/ML-v01.03 + - Further specify deployment scenario 1.5, with training in the Non-RT RIC and inference in the E2 Node (Option 2a). + - Specify a new deployment scenario with training (potentially for other than reinforcement ML tasks) in the Near-RT RIC, ML Model management in the Non-RT RIC, and inference in the E2 Node (Option 2b). + +###### WG5 (O1) Impact / WG10 (SMO, O1) Impact + +- No impact identified + - Trained ML Model transfer from Near-RT RIC to SMO as part of the ML Model management (Option 2b) – using file transfer. + - Trained ML Model deployment from SMO to O-CU as part of the ML Model management (Options 2a and 2b) – using file transfer. + +#### 3.4.2.4 Discussion of Architecture Options + +Comparing architecture deployment Options 1a, 2a with 1b, 2b: + +| | Option 1a, 2a | Option 1b, 2b | +|------------------------------------------------|-----------------------------------------------------------------|--------------------------------------------------------------| +| ML Training location | Non-/Near- RT RIC | Non-/Near-RT RIC | +| ML Inference location | Non-/Near-RT RIC | E2 Node | +| Suitable deployments | Aggregated architecture or O-CUs controlling few DUs | Disaggregated architectures with O-CU controlling many O-DUs | +| E2 capacity requirements | high capacity & continuous (ML training & inference) | flexible capacity & temporary (only for ML training) | +| E2 delay requirements | delay critical | not delay critical (offline training) | +| Control loop supported | slower | faster possible | +| Model complexity and optimization scope | more complex models (incl. wide area optimization across O-CUs) | more simple models (optimization within the O-CU) | + +**Table 3.4.2.4-1.** + +As can be seen from Table 3.4.2.4-1, the architecture options target different deployments with different requirements on E2 capacity and may differ in terms of the optimization scope. + +This means both architecture options are viable options for SSB Burst Set, DM-RS and CSI-RS configuration optimization. The standard should not mandate the one or the other option, but it should be up to the vendor to make this decision on a per product basis. This leaves room for enhancements over time and for operators to choose different architectures for different deployment options. + +### 3.4.3 Feasibility and Gain/Complexity Analysis + +#### 3.4.3.1 Feasibility and Gain Analysis + +##### A. Near-RT RIC Deployment Architecture (SS Burst Set Configuration Optimization): + +This section we present calculated peak SE gain trends with varying SS Burst Configurations, discusses suitability of using AI/ML based optimization techniques for choosing deployment specific, slow time varying optimal SS Burst Set configurations. Also, highlighted tradeoff between choosing lower SS Burst Set configuration and achievable SE gains while meeting initial access latency KPI target set by the operator. + +###### Goal of this discussion: + +One aspect of presenting these results is to highlight the opportunity of significant SE gains when optimal configuration is chosen and applied to the gNB/TRP. Another aspect is to highlight the necessity of applying AI/ML based optimization techniques to these network performance optimization problems. + +AI/ML based optimization techniques are ideally suitable for 3GPP NR network optimization problems. More and more automations are expected with growing network deployment and optimization complexity. ML based intelligent agents are equipped to handle complex optimizations with trade-offs + +between long-term and short-term benefits. AI/ML processes learns autonomously, without the human intervention with domain expertise making them ideally suitable for time varying network function optimizations. + +###### What result is presented: + +Impact of SS Burst Set configuration optimization on system overhead resulting in gNB Spectral Efficiency gain and feasibility of using AI/ML techniques for such large parameter based constrained optimization problem. + +Presented results are peak spectral efficiency gain trends when different and allowable SS Burst Set configurations (Number of SS Blocks in a SS Burst Set and SS Burst Set periodicity) are chosen. Observed peak spectral efficiency (SE) gains are the result of system overhead reduction. Job of the AI/ML optimizer is to infer an optimal SS Burst Set configuration based on the target deployment scenario and slow time varying network usage patterns constrained to initial access latency target set by the operator. + +SE graphs are **per gNB Peak SE** results (ITU Document 5D/50-E 11 February 2020, 3GPP NR 38.336) for varying SS block number and SS Burst periodicity in 3GPP NR FR1 and FR2 systems with realistic parameters configurations ranges supported by 3GPP specifications for respective frequency bands. + +One can observe from the presented results below that SE gain is maximum when lowest SS Burst Set configuration is chosen for the system (within the configuration range supported by 3GPP). However, this would lead to degraded Initial Access (IA) latency KPI. Thus, we need to opt for constrained optimization techniques to avoid increase in IA latency beyond operator mentioned limit. Another important aspect of the optimizer is to consider slow time varying network usage pattern and time varying UE distribution patterns which can be inferred from the available measurements, observations, PIs. Thus, the optimizer will provide slow time varying SS Burst Set configuration per gNB/TRP which will result in system overhead reduction and hence can achieve optimal SE gain per gNB. + +AI/ML based constrained optimization techniques are ideally suitable for large-scale (multi-gNB/TRP) and multi-parameter constrained optimization problems and result in proactive and predictable solutions for realistic NR network deployment scenarios. Traditionally one fixed configuration is decided for the network by the skilled manpower and applied during deployment of the network hence results in inefficient network design. + +###### Tradeoff between SS Burst Set configuration optimization and SE improvement: + +Directly selecting the lowest SS Burst Set configuration (without considering the network usage pattern) to reduce reference signaling overhead will result in reduced SS Block density in both time and frequency directions. This may result in (a) increased initial access latency, (b) reduced mobility support (L3 mobility performance), (c) inferior time and frequency tracking performance, (d) potentially clustered access to the network (impacting the L1/2 beam management (for GoB based MIMO schemes), (d) reduced PBCH transmission frequency in SSB and hence impact timely availability of the system information blocks. + +Thus, the important role of an AI/ML optimization techniques is to constrain the SB Block optimization to meet KPI targets set by the operator. Example KPI based constraints are operator defined IA latency target and coverage, target mobility support by the network, beam management KPIs (tracking and acquisition performances). Inferences generated by the AI/ML engine will be usage dependent slow time varying configurations per gNB/TRP. Here optimization techniques should not exclude possibility of joint optimizations example SSB and CSI-RS when required. + +###### Example Peak-SE Computation Scenario Descriptions: + +- a) SE gain computational results are presented for three NR systems configurations: + 1. FR2: BW = 100MHz, SCS =120KHz + 2. BW = 90MHz FR1 (with 8 SS Block frequency domain multiplexing), + 3. BW = 90MHz FR1 (with 12 SS Block frequency domain multiplexing), +- b) 1 gNB Peak SE computation +- c) 1 UE SU-MIMO in one sector +- d) Available DL antenna ports $\geq$ Max layers supported by 3GPP NR specs for target system configuration +- e) Cell reference signal configurations are given in ITU Document 5D/50-E 11 February 2020 + +###### 1. NR FR2 System Configuration (DL): SS Burst Set Configuration Optimization + +- NR Numerology: FR2, +- BW = 100MHz, SCS = 120KHz, +- Maximum allocated number PRB = 66 +- Maximum modulation order = 8 +- {Minimum, Maximum} SS Block number per SS Burst Supported: {8, 64} +- Maximum number of layers in DL: 6 (1 UE, SU-MIMO) +- Max coding rate: 0.9258 +- SSBurst Set config optimization goals: +- Reduce Number of SS Blocks/SS Burst Set through KPI optimization + - Reduce frequency of SS Burst Sending + +![Line graph showing Spectral Efficiency (SE) in bits/sec/Hz versus SS Block number in a SS Burst for different SS Burst Periodicities (Tss). The graph shows five data series: Tss = 5ms (blue circles), Tss = 10ms (orange diamonds), Tss = 20ms (yellow triangles), Tss = 40ms (purple crosses), and Tss = 80ms (green asterisks). All series show a decreasing trend in SE as the SS Block number increases. The Tss = 5ms series shows the steepest decline, while the Tss = 80ms series shows the least decline. An arrow labeled 'ML Opt. Target' points to the Tss = 5ms series at approximately SS Block number 40 and SE 18.](decab4156c1e7b9b4ffc0393e70be588_img.jpg) + +**Spectral Efficiency(SE) Vs SS Block Number/SSBurst** +SS Burst Periodicity: 5/10/20/40/80ms, SCS: 120KHz, BW: 100 MHz + +| SS Block number in a SS Burst | Tss = 5ms | Tss = 10ms | Tss = 20ms | Tss = 40ms | Tss = 80ms | +|-------------------------------|-----------|------------|------------|------------|------------| +| 8 | 26.8 | 28.2 | 28.8 | 29.2 | 29.5 | +| 16 | 24.5 | 27.0 | 28.0 | 28.8 | 29.2 | +| 24 | 22.2 | 25.8 | 27.5 | 28.5 | 29.0 | +| 32 | 20.0 | 24.5 | 27.0 | 28.2 | 28.8 | +| 40 | 17.8 | 23.5 | 26.5 | 27.8 | 28.5 | +| 48 | 15.5 | 22.5 | 25.8 | 27.5 | 28.2 | +| 56 | 13.2 | 21.2 | 25.2 | 27.2 | 28.0 | +| 64 | 11.0 | 20.0 | 24.8 | 27.0 | 27.8 | + +Line graph showing Spectral Efficiency (SE) in bits/sec/Hz versus SS Block number in a SS Burst for different SS Burst Periodicities (Tss). The graph shows five data series: Tss = 5ms (blue circles), Tss = 10ms (orange diamonds), Tss = 20ms (yellow triangles), Tss = 40ms (purple crosses), and Tss = 80ms (green asterisks). All series show a decreasing trend in SE as the SS Block number increases. The Tss = 5ms series shows the steepest decline, while the Tss = 80ms series shows the least decline. An arrow labeled 'ML Opt. Target' points to the Tss = 5ms series at approximately SS Block number 40 and SE 18. + +**Figure 3.4.3.1-1. Computed SE variation plot with SS Block configuration change {SS Block number and SS Burst Set periodicity}.** + +Achievable peak SE Improvement factor for the SSB resources saving ignoring potential performance degradation in this gNB is 200%. + +Results shows high SE improvement possibility in mmWave systems when optimal SS Block configuration is adopted in each gNB/TRP. Application of AI/ML will help in predictive and proactive inferences with reduced system overhead. + +###### 2. NR FR1 System Configuration (DL): SS Burst Set Configuration Optimization + +System Numerology: FR1 + +BW = 90MHz, SCS = 30KHz, + +Maximum allocated number PRB = 245 + +Maximum modulation order = 8 + +{Minimum, Maximum} SS Block number per SS Burst Supported: {1,8} + +Maximum number of layers in DL: 8 (1 UE. SU-MIMO) + +Multi-SS Block capability: 8 per slot (not shown in the figure) + +Max coding rate: 0.9258 + +SSB Config optimization goals: + +- Reduce Number of SS Blocks/SS Burst Set by optimization +- Reduce frequency of SS Bust Sending + +![Line graph showing Spectral Efficiency (SE) in bits/sec/Hz versus SS Block number in a SS Burst (1 to 8). Five lines represent different SS Burst Periodicities (Tss): 5ms (blue), 10ms (orange), 20ms (yellow), 40ms (purple), and 80ms (green). SE generally decreases as SS Block number increases. The 5ms Tss line shows the steepest decline, while the 80ms Tss line shows the least decline. An arrow points to the 5ms Tss line at block 5, labeled 'ML Opt. Target'.](9ae3cc9d2aad88294860939e4259f01d_img.jpg) + +**Spectral Efficiency(SE) Vs SS Block Number/SSBurst** +SS Burst Periodicity: 5/10/20/40/80ms, SCS: 30KHz, BW: 90 MHz, MultiBlockFactor =8 + +| SS Block number | Tss = 5ms | Tss = 10ms | Tss = 20ms | Tss = 40ms | Tss = 80ms | +|-----------------|-----------|------------|------------|------------|------------| +| 1 | 34.4 | 34.9 | 35.2 | 35.3 | 35.4 | +| 2 | 33.8 | 34.6 | 35.0 | 35.2 | 35.3 | +| 3 | 33.2 | 34.3 | 34.8 | 35.1 | 35.2 | +| 4 | 32.7 | 34.0 | 34.6 | 35.0 | 35.2 | +| 5 | 32.1 | 33.7 | 34.4 | 34.9 | 35.1 | +| 6 | 31.5 | 33.4 | 34.2 | 34.8 | 35.1 | +| 7 | 31.0 | 33.1 | 34.0 | 34.7 | 35.0 | +| 8 | 30.4 | 32.8 | 33.8 | 34.6 | 35.0 | + +Line graph showing Spectral Efficiency (SE) in bits/sec/Hz versus SS Block number in a SS Burst (1 to 8). Five lines represent different SS Burst Periodicities (Tss): 5ms (blue), 10ms (orange), 20ms (yellow), 40ms (purple), and 80ms (green). SE generally decreases as SS Block number increases. The 5ms Tss line shows the steepest decline, while the 80ms Tss line shows the least decline. An arrow points to the 5ms Tss line at block 5, labeled 'ML Opt. Target'. + +**Figure 3.4.3.1-2. Spectral efficiency variation over SS Block number and SS Burst Set periodicity configurations plot for FR1 system with higher PRBs.** + +Achievable peak SE Improvement factor for the SSB resources saving ignoring potential performance degradation in this gNB is ~16.4%. Results shows noticeable SE improvement possibility in FR1 system when optimal SS Block configuration is adopted in each gNB/TRP. Application of AI/ML will help in predictive and proactive convergence. + +###### 3. NR FR1 System Configuration (DL): SS Burst Set Configuration Optimization + +System Numerology: FR1 + +BW = 90MHz, SCS = 30KHz, + +Maximum allocated number PRB = 245 + +Maximum modulation order = 8 + +{Minimum, Maximum} SS Block number per SS Burst Supported: {1,8} + +Maximum number of layers in DL: 8 + +Multi-SS Block capability: 12 per slot (not shown in the figure) + +Max coding rate: 0.9258 + +SSB Config optimization goals: + +- Reduce Number of SS Blocks/SS Burst Set by optimization +- Reduce frequency of SS Burst Sending + +![Line graph showing Spectral Efficiency (SE) in bits/sec/Hz versus SS Block number in a SS Burst. The graph shows five data series for different SS burst periodicities: 5ms (green), 10ms (purple), 20ms (yellow), 40ms (orange), and 80ms (blue). All series show a decreasing trend in SE as the SS block number increases from 1 to 8. The 80ms periodicity series shows the steepest decline, starting at ~34.2 and ending at ~28.1. An arrow points to the 80ms series with the label 'ML Opt. Target'.](a08a226499932f48cacdcd456f8499b8_img.jpg) + +**Spectral Efficiency(SE) Vs SS Block Number/SSBurst** +SS Burst Periodicity: 5/10/20/40/80ms, SCS: 30KHz, BW: 90 MHz, MultiBlockFactor =12 + +| SS Block number in a SS Burst | 5ms Periodicity (SE) | 10ms Periodicity (SE) | 20ms Periodicity (SE) | 40ms Periodicity (SE) | 80ms Periodicity (SE) | +|-------------------------------|----------------------|-----------------------|-----------------------|-----------------------|-----------------------| +| 1 | 35.4 | 35.2 | 35.1 | 34.8 | 34.2 | +| 2 | 35.3 | 35.1 | 34.9 | 34.4 | 33.3 | +| 3 | 35.2 | 35.0 | 34.7 | 33.9 | 32.4 | +| 4 | 35.1 | 34.9 | 34.5 | 33.5 | 31.6 | +| 5 | 35.0 | 34.8 | 34.2 | 33.1 | 30.7 | +| 6 | 34.9 | 34.7 | 34.0 | 32.7 | 29.8 | +| 7 | 34.8 | 34.6 | 33.8 | 32.2 | 29.0 | +| 8 | 34.7 | 34.5 | 33.6 | 31.8 | 28.1 | + +Line graph showing Spectral Efficiency (SE) in bits/sec/Hz versus SS Block number in a SS Burst. The graph shows five data series for different SS burst periodicities: 5ms (green), 10ms (purple), 20ms (yellow), 40ms (orange), and 80ms (blue). All series show a decreasing trend in SE as the SS block number increases from 1 to 8. The 80ms periodicity series shows the steepest decline, starting at ~34.2 and ending at ~28.1. An arrow points to the 80ms series with the label 'ML Opt. Target'. + +**Figure 3.4.3.1-3. SE variation over SS Block number and SS Burst Set periodicity configuration for FR1 system with FDM in SSB transmission.** + +SE plot shows significant gain (max 25.6%) can be achieved in FR1 systems having multi-SSB SSB transmission even when large PRBs are used for data transmission. Note that in this scenario the number of SSB transmissions in frequency domain multiplexing is increased to 12. + +Achievable peak SE Improvement factor for the SSB resources saving ignoring potential performance degradation in this gNB is ~25.6%. + +##### B. Use Case Motivation for Near-RT RIC Deployment Architectures: + +For Near-RT RIC based architecture/deployment scenario use-cases, goal is to optimize CSI-RS and DMRS transmission configurations and CSI reporting configurations where applicable. Based on the observations, measurements and KPI targets (training data) and using appropriate constrained optimization techniques, AI/ML model/agent will train the model for Near-RT RIC deployment. + +Deployed model can infer target usage specific optimal configurations for CSI-RS and DMRS which will minimize the system overhead and hence will provide SE gains. AI/ML inferred configuration are not necessarily the lowest configurations. + +In line with SSB use-case scenario, to create motivation around Near-RT RIC deployment-based use cases, below we have presented achievable peak Spectral Efficiency results for individual DMRS and CSI-RS transmission configuration optimizations. Presented SE graphs are per gNB Peak SE results (ITU Document 5D/50-E 11 February 2020, 3GPP NR 38.336) with varying (a) DMRS transmission configurations and (b) CSI-RS transmission configurations following 3GPP NR (FR1 and FR2) standards with realistic system parameter configurations for respective frequency bands. It is also important that both DMRS and CSI-RS optimization techniques can be jointly applied to the system for a target deployment scenario and use cases to achieve improved SE performance. + +###### a) DMRS Configuration Optimization: Example System Configuration + +| | NR FR1 | NR FR2 | +|-------------------------------|-----------------------|---------------------------| +| BW & SCS | 90MHz, 30KHz | BW = 100MHz, SCS = 120KHz | +| Maximum PRB Number | 245 | 66 | +| Maximum Modulation Order | 8 | 8 | +| SS Block number per SS Burst | 8 | 64 | +| SS Burst Set Periodicity | 20ms | 20ms | +| SS Burst FDM | 1 | 1 | +| Maximum number of layers (DL) | 6 | 6 | +| Max coding rate | 0.9258 | 0.9258 | +| DMRS Type | Type-1, Single Symbol | Type-1, Single Symbol | +| DMRS Density (#RE/RB/Slot) | 6,12,18,24 | 6,12,18,24 | + +**Table 3.4.3.1-1. System configurations for FR1 and FR2 system to measure peak SE when DMIRS configuration is varied** + +1 Plots for peak SE for FR1 and FR2 System. + +![Two line graphs showing Peak Spectral Efficiency (SE) vs. Type-1 One Symbol DMRS Density for FR1 and FR2 systems. The left graph is for FR1 (SCS: 30KHz, BW: 90MHz) and the right graph is for FR2 (SCS: 120KHz, BW: 100MHz). Both graphs show a linear decrease in SE as DMRS Density increases from 6 to 24.](4036ae059aedff1b609283770fd4cbab_img.jpg) + +**Peak Spectral Efficiency(SE) Vs Type-1 One Symbol DMRS Density** + DMRS Density in (#RE/RB/Slot), SCS: 30KHz, BW: 90MHz + +| DMRS Density (#RE/RB/Slot) | SE (bits/sec/Hz) - FR1 | +|----------------------------|------------------------| +| 6 | 36.8 | +| 12 | 35.1 | +| 18 | 33.4 | +| 24 | 31.7 | + +**Peak Spectral Efficiency(SE) Vs Type-1, One Symbol DMRS Density** + DMRS Density in (#RE/RB/Slot), SCS: 120KHz, BW: 100MHz + +| DMRS Density (#RE/RB/Slot) | SE (bits/sec/Hz) - FR2 | +|----------------------------|------------------------| +| 6 | 26.5 | +| 12 | 24.5 | +| 18 | 22.5 | +| 24 | 20.5 | + +Two line graphs showing Peak Spectral Efficiency (SE) vs. Type-1 One Symbol DMRS Density for FR1 and FR2 systems. The left graph is for FR1 (SCS: 30KHz, BW: 90MHz) and the right graph is for FR2 (SCS: 120KHz, BW: 100MHz). Both graphs show a linear decrease in SE as DMRS Density increases from 6 to 24. + +**Figure 3.4.3.1-4. Peak SE variation over DMRS Density (#RE/RB/Slot) for Type 1, Single Symbol DMRS allocation for (a) FR1 and (b) FR2 systems with no FDM in SSB transmission.** + +For both FR1 and FR2, peak SE plots from Figure 3.4.3.1-4 shows noticeable SE improvement can be achieved with the system configurations indicated in Table 3.4.3.1-1. For FR1 max SE gain 16.7% and for FR2 max can be achieved is approximately 27.3% assuming lowest DMRS configuration is used, resulting in resources saving ignoring potential performance degradation in this gNB. + +Directly configuring (without considering the network usage pattern) the lower configurations will degrade the channel estimation performance and related other parameter estimations accuracies, impact achievable throughput for higher mobility scenarios. Thus, one of the important jobs of the AI/ML engine is to take Operator's defined KPIs (parameter estimation accuracy targets, mobility support etc. which are usage dependent parameters), constrain the optimization to target KPIs from operator and infer suitable configurations. + +###### b) CSI-RS Configuration Optimization: Example System Configuration + +| | NR FR1 | NR FR2 | +|-------------------------------|-----------------------|---------------------------| +| BW & SCS | 90MHz, 30KHz | BW = 100MHz, SCS = 120KHz | +| Maximum PRB Number | 245 | 66 | +| Maximum Modulation Order | 8 | 8 | +| SS Block number per SS Burst | 8 | 8 | +| SS Burst Set Periodicity | 5ms | 5ms | +| SS Burst FDM | 12 | 3 | +| Maximum number of layers (DL) | 6 | 6 | +| Max coding rate | 0.9258 | 0.9258 | +| DMRS Type | Type-1, Single Symbol | Type-1, Single Symbol | +| DMRS Density (#RE/RB/Slot) | 12 | 24 | +| CSI-RS Density (#RE/RB/Slot) | 32 | 8 | +| CSI-RS Tx in every kth Slot | 4 : 320 | 4 : 640 | + +**Table 3.4.3.1-2. System configurations for FR1 and FR2 system to measure peak SE when CSI-RS configuration is varied** + +Plots for peak SE for FR1 and FR2 System. + +![Two line plots showing Peak Spectral Efficiency (SE) vs CSI-RS Overhead for FR1 and FR2 systems. The left plot (a) is for FR1 (90MHz BW, 30KHz SCS) and the right plot (b) is for FR2 (100MHz BW, 120KHz SCS). Both plots show SE increasing with CSI-RS periodicity and then plateauing.](23123813b4d6708e8c018550c33af9a4_img.jpg) + +**Spectral Efficiency(SE) Vs CSI-RS Overhead** +CSI-RS Periodicity, Density 32RE/RB/TxSlot, SCS:30KHz, BW:90MHz + +**Peak Spectral Efficiency(SE) Vs CSI-RS Overhead** +CSI-RS Periodicity, Density:8-RE/RB/TxSlot, SCS:120KHz, BW:100MHz + +Two line plots showing Peak Spectral Efficiency (SE) vs CSI-RS Overhead for FR1 and FR2 systems. The left plot (a) is for FR1 (90MHz BW, 30KHz SCS) and the right plot (b) is for FR2 (100MHz BW, 120KHz SCS). Both plots show SE increasing with CSI-RS periodicity and then plateauing. + +**Figure 3.4.3.1-5. Peak SE variation over CSI-RS periodicity (#RE/RB/Slot) for (a) FR1 and (b) FR2 systems with FDM in SSB transmission.** + +For both FR1 and FR2, peak SE plots from Figure 3.4.3.1-5 shows approximately 10% improvement can be achieved for the system with configurations as shown in Table 3.4.3.1-2. For FR1 max SE gain 10.84% and for FR2 max can be + +achieved is approximately 9.87% assuming lowest CSI-RS configuration is used which results in resources saving ignoring potential performance degradation in this gNB. For FR2 system, for the above peak SE plot, system uses number of SSB blocks as 8 and number of CSI-RS beams as 8 per SSB beam (joint SSB beam -CSI-RS beam acquisition). + +Directly configuring (without considering the network usage pattern) lower CSI-RS acquisition/beam management configurations may degrade the CSI feedback quality which has direct impact on the achievable throughput (FR1) or may impact beam measurement performance (FR2). Thus, one of the important jobs of the AI/ML engine is to take Operator's defined KPIs (CSI accuracy, beam acquisition KPIs) and constrain the optimization with the target KPIs and infer suitable configuration. + +3GPP NR standard allows max 32 port CSI-RS transmission. It is important to note that SSB beam and CSI-RS optimizations are closely related when SSB and CSI-RS are jointly used for beam measurement in NR FR2 systems. In this case FR2 system will be limited by max 8 SS Blocks transmission per SS Burst and each SS beam will have 8 CSI-RS for P2 based beam measurement which is used as scenario for SE calculations in Figure 3.4.3.1-5. + +#### 3.4.3.2 Complexity + +Complexity of AI/ML based optimization depends on the type of algorithm used for the optimization, size of the training data set, feature list length. Computational power and memory availability of the model training and inference host will also impact training and inference generation time. Typical learning algorithms have large model training time complexity compared to inference generation. + +One example is with logistics regression based supervised learning algorithms, training phase time complexity is $O(p^2n + p^3)$ and during prediction time complexity is $O(p)$ where $p$ is the number of features and $n$ is the number of training example. + +Thus, offline training of the AI/ML model is desirable and recommended in all the sub sub-uses cases presented herein (namely SS Burst Set, CSI-RS, and DMRS configuration optimization use cases). + +Considering state of the art silicon technology availability in the network side we can assume that computation power (of the training and inference host) has improved significantly over last decade following Moor's Law, through multicore processor designs and parallel programming technology. Thus, large computation capacity at the model training and inference host are available for these optimizations' problems to run. Including training, inferences can be generated at rAPP ( $\geq 1$ sec) and Near-RT RIC ( $< 1$ sec) control loops efficiently with appropriate selection of training data sets size and feature list for AI/ML algorithms. + +# 4 L1 / L2 Beam Management + +## 4.1 Overview + +In 5G NR, mmWave communication using a large bandwidth is one of the key technologies to achieve high-data rate and capacity improvement. However, mmWave frequencies are suffered from high propagation loss including unexpected signal blockages in a mobile environment. To overcome these challenges, directional-beam transmission enabled by hybrid analogue-digital beamforming with large scale antenna array is typically applied at BS side at least. Under this hybrid beamforming architecture, achieving fine beam alignment between BS and UE beams becomes a prerequisite for successful data transmission and reception. A set of Layer 1 (i.e., physical layer) and Layer 2 (i.e., medium access control layer) procedures to acquire and maintain a set of BS and/or UE beams for DL and UL transmission/reception is referred to as L1/L2 beam management. In 3GPP, the beam management procedures that control the determination and maintenance of the serving beam(s) for each UE within a cell has been firstly specified in Release 15. The O-RAN architecture offer opportunities to improve beam management performance by utilizing Non-RT RIC and/or Near-RT RIC to assist E2 nodes to realize intelligent solution. + +## 4.2 Solution 1: AI/ML-assisted Beam Selection Optimization + +### 4.2.1 Problem Statement and Value Proposition + +The L1/L2 beam management procedures that establish and maintain the highly directional transmission link between BS and UE play an important role to enable high quality communications under mmWave frequencies. The current 3GPP 5G NR standard support good flexibility of UE-specific configuration in terms of beam measurement, beam report and beam indication. However, achieving accurate beam alignment between BS and UE is challenging and costly, and a trade-off between network performance improvement and signaling overhead need to be solved. Without employing frequent beam measurement and measurement report, connection between BS and UE may be easily interrupted due to UE movement or blockage, in particular under high mobility scenarios. However, the number of required resources for frequent beam measurement and measurement report will cause an overhead problem which may decrease the overall network throughput. Without an intelligent solution, the network has to face an either-or situation, either high reliability with large signaling overhead or small signaling overhead with poor reliability. + +In recent years, application of AI/ML techniques in mobile communication networks has drawn a lot of interest. AI/ML techniques can be also used as a powerful tool which enable RAN to make quicker and smarter decision in the beam management related procedures, which will contribute to improved network performance in terms of throughput and reliability. In particular, how to improve the performance of beam acquisition and tracking based on the existing 5G NR standard should be considered. AI/ML-assisted solutions can be used to estimate the quality of SSB/CSI-RS beams based on limited beam measurement and/or UE geolocation information, which allows fast beam acquisition and beam failure recovery and ensures reliable radio link against blockage, especially in mmWave. AI/ML-assisted solutions can also be used to predict a future beam(set), beam switching events or blockage events based on historical measurement reports and/or UE geolocation information. Higher accuracy in beam tracking, lower signaling overhead and low latency in beam switching are essential to guarantee service continuity for UEs. The L1/L2 beam management optimization is particularly relevant for mmWave frequencies but may also be applicable for sub-6GHz frequencies. + +Potential benefits of AI/ML assisted beam management will include signaling overhead reduction, latency reduction and reliability improvement. + +### 4.2.2 Architecture/Deployment Options + +#### 4.2.2.1 Option 1 – Non/Near-RT RIC based Beam Selection Optimization + +To enable an intelligent beam management in the O-RAN architecture, interaction between SMO, Non-RT RIC, Near-RT RIC and E2 nodes should be achieved. SMO needs to collect necessary KPIs, beam-related measurement from E2 nodes and enrichment information (e.g., UE geolocation information) from external application/server, if required, to support AI/ML model training and performance monitoring which is hosted by Non-RT RIC. In this case, Non-RT RIC can train the AI/ML model for beam management optimization based on beam-level measurements collected by UE measurement report and/or drive test and decide whether to re-train/fine-tune the AI/ML model based on the performance monitoring. Then the trained AI/ML model can be deployed to Near-RT RIC via O1 interface for beam management related inference. + +The AI/ML model training and inference to support beam management optimization can be done for different objectives, such as, to reduce beam measurement overhead and to improve the connection reliability, depending on implementation and operator's requirements. The beam management optimization for different objectives can follow the general process as shown below. + +``` + +1 @startuml +2 skinparam ParticipantPadding 4 +3 skinparam BoxPadding 8 +4 skinparam defaultFontSize 12 +5 +6 Box "Service Management and Orchestration" #gold +7 Participant CC as "Collection & Control" +8 Participant NON as "Non-RT RIC" +9 End box +10 +11 Box "O-RAN" #lightpink +12 Participant NEAR as "Near-RT RIC" +13 Participant RAN as "E2 Nodes" +14 End box +15 +16 Box "External" #lightcyan +17 Participant AS as "Application Server" +18 End box +19 +20 group Data Collection +21 CC -> RAN : <>Request data collection for model training +22 RAN -> CC : <>Data collection +23 group Opt: Enrichment Information Collection (for training) +24 CC -> AS : Request enrichment information +25 AS -> CC : Enrichment information collection (UE position) +26 end +27 CC -> NON: Retrieval of collected data +28 end +29 +30 group AI/ML Workflow +31 NON -> NON : AI/ML model training +32 NON -> NEAR : <>Deploy AI/ML model +33 end +34 +35 group Opt:Enrichment Information Collection (for inference) +36 CC -> AS : Request enrichment information +37 AS -> CC : Enrichment information collection (UE position) +38 CC -> NON : Retrieval of collected data +39 NON -> NEAR : <>Enrichment information (UE position) +40 end +41 +42 group E2 Control & Policy +43 NEAR -> RAN : <>Request data collection for model inference +44 RAN -> NEAR : <>Data collection +45 NEAR -> NEAR : AI/ML model inference +46 NEAR -> NEAR : E2 control or policy generation +47 NEAR -> RAN : <>Control or policy message +48 end +49 +50 group Performance Evaluation and Optimization +51 CC -> RAN : <>Request data collection +52 RAN -> CC : <>Data collection +53 group Opt: Enrichment Information Collection (for training) +54 CC -> AS : Request enrichment information +55 AS -> CC : Enrichment information collection (UE position) +56 end +57 CC -> NON : Retrieval of collected data +58 NON -> NON : Performance monitoring and evaluation +59 NON -> NON : AI/ML model retraining and update +60 NON -> NEAR : <>Update AI/ML model +61 +62 end +63 @enduml + +``` + +![Flow diagram for Non/Near-RT RIC based Beam Selection Optimization. The diagram shows interactions between Service Management and Orchestration (Collection & Control, Non-RT RIC), O-RAN (Near-RT RIC, E2 Nodes), and External (Application Server). The process includes Data Collection, Opt: Enrichment Information Collection (for training), AI/ML Workflow (AI/ML model training, Deploy AI/ML model), Opt: Enrichment Information Collection (for inference), E2 Control & Policy (Request data collection for model inference, Data collection, AI/ML model inference, E2 control or policy generation, Control or policy message), and Performance Evaluation and Optimization (Request data collection, Data collection, Opt: Enrichment Information Collection (for training), Performance monitoring and evaluation, AI/ML model retraining and update, Update AI/ML model).](4e57f2b463ea0be87bacd899449acb39_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management and Orchestration + participant O_RAN as O-RAN + participant External as External + participant CC as Collection & Control + participant NRT_RIC as Non-RT RIC + participant Near_RT_RIC as Near-RT RIC + participant E2_Nodes as E2 Nodes + participant App_Server as Application Server + + SMO->>O_RAN: <>Request data collection for model training + O_RAN->>SMO: <>Data collection + SMO->>O_RAN: Opt: Enrichment Information Collection (for training) + SMO->>App_Server: Request enrichment information + App_Server->>SMO: Enrichment information collection (UE position) + SMO->>O_RAN: Retrieval of collected data + SMO->>O_RAN: AI/ML Workflow + SMO->>O_RAN: AI/ML model training + O_RAN->>SMO: <>Deploy AI/ML model + SMO->>O_RAN: Opt: Enrichment Information Collection (for inference) + SMO->>App_Server: Request enrichment information + App_Server->>SMO: Enrichment information collection (UE position) + SMO->>O_RAN: Retrieval of collected data + O_RAN->>SMO: <>Enrichment information (UE position) + SMO->>O_RAN: E2 Control & Policy + O_RAN->>E2_Nodes: <>Request data collection for model inference + E2_Nodes->>O_RAN: <>Data collection + O_RAN->>SMO: AI/ML model inference + SMO->>O_RAN: E2 control or policy generation + O_RAN->>SMO: <>Control or policy message + SMO->>O_RAN: Performance Evaluation and Optimization + SMO->>O_RAN: <>Request data collection + O_RAN->>SMO: <>Data collection + SMO->>O_RAN: Opt: Enrichment Information Collection (for training) + SMO->>App_Server: Request enrichment information + App_Server->>SMO: Enrichment information collection (UE position) + SMO->>O_RAN: Retrieval of collected data + SMO->>O_RAN: Performance monitoring and evaluation + O_RAN->>SMO: AI/ML model retraining and update + SMO->>O_RAN: <>Update AI/ML model + +``` + +Flow diagram for Non/Near-RT RIC based Beam Selection Optimization. The diagram shows interactions between Service Management and Orchestration (Collection & Control, Non-RT RIC), O-RAN (Near-RT RIC, E2 Nodes), and External (Application Server). The process includes Data Collection, Opt: Enrichment Information Collection (for training), AI/ML Workflow (AI/ML model training, Deploy AI/ML model), Opt: Enrichment Information Collection (for inference), E2 Control & Policy (Request data collection for model inference, Data collection, AI/ML model inference, E2 control or policy generation, Control or policy message), and Performance Evaluation and Optimization (Request data collection, Data collection, Opt: Enrichment Information Collection (for training), Performance monitoring and evaluation, AI/ML model retraining and update, Update AI/ML model). + +Figure 4.2.2.1-1. Flow diagram for Non/Near-RT RIC based Beam Selection Optimization + +An intelligent solution can be designed and implemented to optimize the beam selection for different objectives. For example, to guarantee the service continuity and eliminate the need for frequent beam measurement, especially for high-mobility UE, the xApp deployed in Near-RT RIC can perform AI/ML model inference to support predictive beam switching. Specifically, the AI/ML model could be utilized to predict the changing trend of beams quality in future, which can help BS to perform proactive beam switching or determine a “high-probability” candidate beam set for further measurement. The process to support this example could be as follows, + +- The E2 Node (O-DU) receives the following information from the UE + - Periodic beam measurements (including L1-RSRP with corresponding CRI or SSBR1) which provide indication of the UE’s best beam + - Data regarding beam switch events for UEs which provides predictive intelligence on future beam switching events + - Beam failure indications + +- Data regarding beam failure events which provides intelligence on beam-switching events to potentially be avoided +- E2 Node provides consolidated measurements and data to the Near-RT-RIC and the Non-RT-RIC (through SMO) +- Non-RT-RIC obtains other enrichment information (such as UE position and velocity) from an application server +- AI/ML model in Non-RT-RIC is trained based on measurement and enrichment data from (potentially) many E2 Nodes +- Non-RT-RIC provides AI/ML model update to Near-RT-RIC +- Using the AI/ML model, the Near-RT-RIC provides control information to the E2 Node, specific to a particular UE, based on the UE's historical beam measurement reports, as well as other possible enrichment information. The control information could include + - New serving beam for UE, or a sequence of future serving beams each with time offsets + - Updated beam measurement set for UE + +##### Requirements + +Measurements/reports from E2 Nodes (for AI/ML model training and performance evaluation): + +| Input Data | | | | | | +|--------------|----------------------|--------------------------------------------------------------------------------------------------------------------|---------|------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------| +| Interface | Source Target → | Name/Description | Units | Reporting Period | New or existing measurement/reporting specification | +| O1 (via SMO) | O-DU →
Non-RT RIC | L1-RSRP measurement at UE-level (in the form of sequence) | dBm | ~x hours/days per cell

(for training) | Existing definition:
3GPP TS 38.214 (Sec. 5.2.1.4.3)
3GPP TS 38.215 (Sec. 5.1.1 and 5.1.2)

New reporting | +| O1 (via SMO) | O-DU →
Non-RT RIC | L1-SINR measurement at UE-level (in the form of sequence) | dB | ~x hours/days per cell

(for training) | Existing definition:
3GPP TS 38.214 (Sec. 5.2.1.4.4)
3GPP TS 38.215 (Sec. 5.1.5 and 5.1.6)

New reporting | +| O1 (via SMO) | O-DU →
Non-RT RIC | CSI-RS Resource Indicator (CRI) and SS/PBCH Block Resource Indicator (SSBRI) at UE-level (in the form of sequence) | Index | ~x hours/days per cell

(for training) | Existing definition:
3GPP TS 38.214 (Sec. 5.2.1)

New reporting | +| O1 (via SMO) | O-DU →
Non-RT RIC | Average DL UE throughput in gNB | Kb/s | ~x hours/days per cell

(for performance evaluation) | Existing definition and reporting:
3GPP TS 28.552 (Sec. 5.1.1.3.1) | +| O1 (via SMO) | O-DU →
Non-RT RIC | Wideband CQI distribution | Integer | ~x hours/days per cell | Existing definition and reporting:
3GPP TS 28.552 (Sec. 5.1.1.11.1) | + +| | | | | | | +|--------------|----------------------|--------------------------------------------------------|---------------|------------------------------------------------------------|------------------------------------------------------------------------| +| | | | | (for performance evaluation) | | +| O1 (via SMO) | O-DU →
Non-RT RIC | MCS distribution in PDSCH | Integer | ~x hours/days per cell

(for performance evaluation) | Existing definition and reporting:
3GPP TS 28.552 (Sec. 5.1.1.12.1) | +| O1 (via SMO) | O-DU →
Non-RT RIC | Optional: Beam failure statistics per cell or per beam | Count/percent | ~x hours/days per cell

(for performance evaluation) | New definition and reporting | + +Table 4.2.2.1-1. + +Measurements/reports from E2 Nodes (for AI/ML model inference): + +| Input Data | | | | | | +|------------|-----------------------|-------------------------------------------------------------------------------------|-------|------------------|-----------------------------------------------------------------------------------------------------------------------| +| Interface | Source Target → | Name/Description | Units | Reporting Period | New or existing measurement/reporting specification | +| E2 | O-DU →
Near-RT RIC | L1-RSRP measurement per UE | dBm | ~per N x 100ms | Existing definition:
3GPP TS 38.214 (Sec. 5.2.1.4.3)
3GPP TS 38.215 (Sec. 5.1.1 and 5.1.2)

New reporting | +| E2 | O-DU →
Near-RT RIC | L1-SINR measurement per UE | dB | ~per N x 100ms | Existing definition:
3GPP TS 38.214 (Sec. 5.2.1.4.4)
3GPP TS 38.215 (Sec. 5.1.5 and 5.1.6)

New reporting | +| E2 | O-DU →
Near-RT RIC | CSI-RS Resource Indicator (CRI) and SS/PBCH Block Resource Indicator (SSBRI) per UE | Index | ~per N x 100ms | Existing definition:
3GPP TS 38.214 (Sec. 5.2.1)

New reporting | + +Table 4.2.2.1-2. + +Enrichment information from application server + +1. UE position +2. UE velocity + +The time granularity of these data collections should be configurable and satisfy the requirements of the AI/ML model + +1 Output Signalling towards E2 Nodes: + +| Output Data | | | | | | +|-------------|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Interface | Source Target → | Name/Description | Units | Reporting Period | New or existing configuration specification | +| E2 | Near-RT RIC →
O-CU/DU | Control/policy related to beam management operations (examples shown as below, details would be FFS)

- Beam measurement/reporting: updated beam measurement set, reporting type and period

- Beam indication: indicate serving beam for UE

- Beam failure recovery: identify the candidates beams for beam failure recovery | - | ~per N x 100ms | Existing configuration:
3GPP TS 38.331 (Sec. 6.3.2)
Related IE (FFS):
CSI-MeasConfig
CSI-Report Config
PDSCH-Config
BeamFailureRecovery Config

3GPP TS 38.321 (Sec. 6.1.3.14 and 6.1.3.15) | + +Table 4.2.2.1-3. + +2 + +3 + +4 ORAN Entity roles: + +5 1) SMO + +6 a) Collect necessary KPIs, measurement reports and enrichment information (e.g., UE position) from E2 nodes +7 and application server. + +8 b) Send collected data to Non-RT RIC for AI/ML model training and performance monitoring. + +9 2) Non-RT RIC + +10 a) Retrieve necessary KPIs, measurement reports and enrichment information (e.g., UE position) from SMO for +11 purpose of constructing/training relevant AI/ML models and performance monitoring. + +12 b) Monitor performance of the AI/ML models based on the KPIs retrieved from SMO and decide whether to re- +13 train/finetune and update the AI/ML models or not. + +14 c) Train the relevant AI/ML models using the retrieved data. + +15 d) Support deployment and update of the AI/ML models into Near-RT RIC over O1 interface. + +16 e) Support communication of policies and enrichment information to Near-RT RIC over A1 interface. + +17 3) Near-RT RIC + +18 a) Support deployment, update and execution of the AI/ML models from Non-RT RIC. + +19 b) Support interpretation and execution of the policies from Non-RT RIC. + +20 c) Collect necessary measurement reports from E2 nodes for the purpose of AI/ML model inference over E2 +21 interface. + +22 d) Retrieve enrichment information from Non-NT RIC over A1 interface. + +23 e) Send control or policy message for beam management operation to E2 nodes. + +24 4) E2 nodes + +25 a) Support data collection with required granularity to SMO and Near-RT RIC over O1 and E2 interface. + +26 b) Apply L1/L2 beam management parameter configuration based on the control or policy message received from +27 Near-RT RIC. + +28 + +#### 4.2.2.2 Option 2 – E2 Node (O-DU) based Beam Selection Optimization + +L1/2 beam management includes a large number of very fast real time functions closely related to the uplink and downlink scheduling in the baseband. The NR L2 scheduling working operates at Transmission Time Interval even lower than 1ms depending on the numerology. It is one of the most demanding and time critical function of the base station that, depending on the bandwidth, will have to handle transmission of multiple GBytes of data traffic. Examples of L1/L2 beam management use cases are beam sweeping, beam measurements, beam reporting, beam acquisition, beam pairing, beam refinement, beam switching, beam indication, beam recovery. Some beam management features may require operating in a faster loop timing than what the E2 loop between Near-RT RIC and E2 Node (e.g, O-DU) allows. Still, AI/ML assisted techniques could achieve substantial gains with acceptable computational costs. In some cases, the ML model might carry intelligence with a local scope, i.e., it adapted to patterns of a single cell on which it was trained. + +Therefore, in another deployment option, the operator can leverage on the data collection capabilities of the E2 interface (for ML training) plus the computational capacity (AI/ML framework) of the RIC(s) for ML training, but perform the ML inference in the E2 Node, e.g., in the O-DU (Figure 4.2.2.2-1. middle). ML Deployment Scenario 1.5 (Technical Report O-RAN.WG2.AI/ML-v01.03) supports training in the Non-RT RIC and inference in the E2 Node. Training in the Near-RT RIC and inference in the E2 Node is a new deployment scenario still to be added to respective specifications (Figure 3.4.2.3-1. right). Related impact on O-RAN WGs is analyzed in sections [FFS]. 3GPP RAN WGs will start working on gNB hosted AI/ML algorithms in 3GPP Rel.18. More details are provided in [FFS: 3GPP TR 37.817]. This O-RAN architecture option introduced in this section will complement the 3GPP AI/ML approach (i.e. model hosted in E2 Node) with RIC based training capabilities and the ability to deploy a trained ML model in the E2 node. + +![Figure 4.2.2.2-1: O-RAN deployment options for ML training and inference. Option 1 shows training and inference in the Non-/Near-RT RIC. Option 2a shows training in the Non-RT RIC and inference in the E2 Node. Option 2b shows training in the Near-RT RIC and inference in the E2 Node.](c3a87de72245cd402af8fb607d1cf231_img.jpg) + +The diagram illustrates three O-RAN deployment options for ML training and inference across different network components: + +- Option 1:** Training and inference occur in the Non-/Near-RT RIC. Data collection for training and inference is handled by the E2 Node. The RIC sends policy and configuration to the E2 Node, which then performs the RAN function. +- Option 2a:** Training occurs in the Non-RT RIC, while inference is performed in the E2 Node. The Non-RT RIC deploys the ML model to the E2 Node. Data collection for training is handled by the E2 Node. +- Option 2b:** Training occurs in the Near-RT RIC, while inference is performed in the E2 Node. The Near-RT RIC deploys the ML model to the E2 Node. Data collection for training is handled by the E2 Node. + +Figure 4.2.2.2-1: O-RAN deployment options for ML training and inference. Option 1 shows training and inference in the Non-/Near-RT RIC. Option 2a shows training in the Non-RT RIC and inference in the E2 Node. Option 2b shows training in the Near-RT RIC and inference in the E2 Node. + +**Figure 4.2.2.2-1. Left: O-RAN deployment Option 1 with both training and inference in the Near-RT RIC. Middle and right: Deployment Options 2a and 2b with ML inference in the RAN node (O-DU) for faster control loop.** + +##### 4.2.2.2.1 Additional O-RAN Standardization Impact + +###### WG2 (Non-RT RIC, A1, R1) Impact + +- O-RAN.WG2.AI/ML-v01.03 + - Further specify deployment scenario 1.5, with training in the Non-RT RIC and inference in the E2 Node (Option 2a). + - Specify a new deployment scenario with training (potentially for other than reinforcement ML tasks) in the Near-RT RIC, ML Model management in the Non-RT RIC, and inference in the E2 Node (Option 2b). + +###### WG5 (O1) Impact / WG10 (SMO, O1) Impact + +- No impact identified. + - Trained ML Model transfer from Near-RT RIC to SMO as part of the ML Model management (Option 2b) – using file transfer. + - Trained ML Model deployment from SMO to O-DU as part of the ML Model management (Options 2a and 2b) – using file transfer. + +#### 4.2.2.3 Discussion of Architecture Options + +Comparing architecture deployment options 1 and 2: + +| | Option 1 | Option 2 | +|-------------------------------------------------|------------------------------------------------------|------------------------------------------------------| +| ML Training location | Non-/Near- RT RIC | Non-/Near-RT RIC | +| ML Inference location | Near-RT RIC | E2 Node | +| E2 capacity requirements | high capacity & continuous (ML training & inference) | flexible capacity & temporary (only for ML training) | +| E2 delay requirements | delay critical | not delay critical (offline training) | +| Processing capabilities | higher capacity possible | capacity limited | +| Control loop supported | slower | faster | +| Scheduler integration of fast algorithms | difficult | easier | +| Model complexity and optimization scope | more complex models (incl. multi-cell optimization) | more simple models (mostly single cell optimization) | + +**Table 4.2.2.3-1.** + +As can be seen from Table 4.2.2.3-1, the two architecture deployment options target different use cases, have different strengths and weaknesses. Requirements on gNB processing and on E2 delay and capacity are quite different. The same problem might be addressed with a single cell optimization or a multi-cell optimization, with a more or less complex ML model. + +While the realization of L1/2 beam management algorithms might sometimes be limited to one of the options (e.g. due to delay or interface constraints), some algorithms might also possibly be realized with both options. Considering that L1/2 beam management techniques are very fast algorithms tightly integrated in the L2 scheduler design, it will be the vendor that evaluates the gain versus the complexity. While a small cell may have very limited processing and backhaul capabilities, a macro base station site might have such capability. This means both architecture options are viable options for L1/2 beam management algorithms and may even co-exist. The standard should not mandate the one or the other option, but it should be up to the vendor to make this decision. This leaves room for enhancements over time and for operators to choose different deployment options. + +### 4.2.3 Impact Analysis on O-RAN Working Groups + +*Editor's note: This is an initial impact analysis as part of the WG1 UCTG work on mMIMO. The intention is to estimate the expected standardization effort within the O-RAN working groups. It is up to the WGs to decide how the mMIMO functionality should be specified in specifications of each WG.* + +#### WG1 (use cases, architecture) Impact + +- O-RAN.WG1.Use-Cases-Analysis-Report + - Update use case 6: Massive MIMO Beamforming Optimization (Section 3.6) +- O-RAN.WG1.Use-Cases-Detailed-Specification + - Update use case 6: Massive MIMO Beamforming Optimization (Section 3.6) + +#### WG2 (Non-RT RIC, A1) Impact + +- O-RAN.WG2.Use-Case-Requirements + - If seen as beneficial, add new use case 6: Massive MIMO Beamforming Optimization based on agreements from pre-normative phase +- O-RAN.WG2.A1TD + - Support exchange of relevant Enrichment Information from Non-RT to Near-RT RIC + +#### WG3 (Near-RT RIC, E2) Impact + +- O-RAN.WG3.UCR + - If seen as beneficial, add new use case 6: Massive MIMO Beamforming Optimization based on agreements from pre-normative phase +- O-RAN.WG3.E2SM-KPM + - For cell-level measurements that are specified in 3GPP (i.e. 3GPP TS 28.552), there would be minor or no direct specification impact. The optional new beam failure statistics might be specified in 3GPP or in O-RAN (FFS). + - For UE-level L1/L2 measurements + - Option 1: If UE-level L1/L2 measurement reporting is added to the 3GPP specification (e.g. 3GPP TS37.320), E2 could refer to 3GPP specification and there will be minor or no direct specification impact. + - Option 2: If UE-level L1/L2 measurement reporting is not added to the 3GPP specifications, O-RAN specific reporting need to be added. Given that measurement definitions already exist in 3GPP, the impact will be minor (noting that E2SM-KPM has already extended the definitions of measurement counters in TS 28.552 to be able to be retrieved per UE level from RAN node). +- O-RAN.WG3.E2SM-RC or creation of new E2SM + - Add new control/policy related to beam management operation + +#### WG5 (O1) Impact + +- O-RAN.WG5.MP + - For cell-level measurements that are specified in 3GPP (i.e. 3GPP TS 28.552), there would be minor or no direct specification impact. The optional new beam failure statistics might be specified in 3GPP or in O-RAN (FFS). + - For UE-level L1/L2 measurements + - Option 1: If UE-level L1/L2 measurement reporting is added to the 3GPP specification (e.g. 3GPP TS37.320), O1 could refer to 3GPP specification and there will be minor or no direct specification impact. + - Option 2: If UE-level L1/L2 measurement reporting is not added to or re-used from the 3GPP specifications, O-RAN would add reporting of these as an extension of O1. Given that measurement definitions already exist in 3GPP, the impact will be moderate, + +Summary: The overall impact on O-RAN specifications is limited, since all the measurement definitions are already defined in 3GPP. There is a new cell level measurement beam failure statistic suggested that is optional. The detailed + +impact might further depend on if required enhancements of measurement reporting (especially UE-level L1/L2 measurements) will be specified in 3GPP or O-RAN specifications. There might be some common parts on specification impact among different sub-features, which may further reduce the overall workload in the normative phase. + +### 4.2.4 Relation and Impact on 3GPP Specification + +In 3GPP, the beam management procedures that control the determination and maintenance of the serving beam(s) for each UE within a cell has been firstly specified in Release 15 and further enhanced in Release 16 and 17. The existing 3GPP standard already support good flexibility of UE-specific configuration in terms of beam measurement/reporting, beam indication and beam failure recovery with regard to fundamental beam-based transmission/reception. To support the L1/L2 beam management optimization in O-RAN would mainly rely on the existing 3GPP standards, and the detailed impact is listed as below, + +Data collection: + +- Cell-level measurements: The definition and reporting of essential measurements is already existing in 3GPP specification (3GPP TS 28.552). Whether and how to support the new measurements which is not essential could be FFS. +- UE-level L1/L2 measurements: The measurements definition is already existing in 3GPP specifications, and the measurements reporting might be added to the existing 3GPP MDT framework (3GPP TS 37.320) or might be added in a new AI/ML Data Collection framework currently discussed in 3GPP. Whether rely on 3GPP or introduce O-RAN specific reporting could be FFS. + +Configuration/Control: + +- The control will rely on the existing control signaling (3GPP TS 38.331/38.321) + +### 4.2.5 Feasibility and Gain/Complexity Analysis + +In mmWave bands, supporting good reliability of connectivity for high mobility UE is challenging. The network needs to rely on frequent beam measurement to track the rapid change of wireless channel, which will require significant signaling overhead. However, UEs with high mobility move along relatively fixed trajectory in many cases. For example, a vehicle traveling at high speed mostly will not suddenly change its driving direction. Therefore, although the optimal beam changes rapidly under the UE's high-speed movement, the trend of change is predictable. The xApp deployed in Near-RT RIC can be used to perform AI/ML model inference to predict the changing trend of beams quality in future, which can help BS to reduce the frequency of beam measurements and/or reduce the number of measured beams. + +#### 4.2.5.1 Simulation Results + +The following part of this section presents the simulation results which show the benefits of beam prediction under an urban street scenario (depicted in Figure 4.2.5.1-1). Within the simulation, vehicular UEs moving along the urban street which is served by one BS, and the BS periodically sends reference signals on all the candidate beams to UE for beam measurement. In the case of the conventional beam switching solution, which is reactive, the BS will configure serving beam for UE according to the most recent beam measurement result. In the case of the AI/ML-based beam solution, which is proactive, the optimal serving beams (i.e., beams sequence with time offset) before the next time of beam measurement can be predicted accurately in advance based on the historical beam measurement report, so that the BS can configure serving beams for UE by following this prediction. The simulation assumptions and results are shown in Table 4.2.5.1-1 and Figure 4.2.5.1-2 respectively. + +![Figure 4.2.5.1-1: A diagram showing a street layout with a central red antenna tower. Several yellow bus icons are positioned along the street, with red arrows indicating their movement in both directions. The background is a light gray map-like texture.](939559840b1f76a24f799c140944fe77_img.jpg) + +Figure 4.2.5.1-1: A diagram showing a street layout with a central red antenna tower. Several yellow bus icons are positioned along the street, with red arrows indicating their movement in both directions. The background is a light gray map-like texture. + +Figure 4.2.5.1-1. Vehicular UEs moving along the urban street in both directions + +| Parameter | Value | +|----------------------------------|----------------------------------------------------------------------------------------------------------------------------------| +| Frequency band | 28 GHz | +| Bandwidth | 100 MHz | +| BS Trans. power | 33 dBm | +| BS height | 6 m | +| BS antenna configuration (M x N) | 8 x 16 antennas | +| Beam set configuration | 64 beams uniformly distribute in horizontal with 5 degrees down tilt | +| Beam measurement period | 50/500/1000 ms | +| Beam measurement report | Best beam index with L1-RSRP | +| UE velocity | 60km/h | +| Mobility model | UEs moving along the urban street in both directions (moving trajectory is randomly generated with different starting/end point) | +| Channel model | Generated by ray-tracing based simulator | + +Table 4.2.5.1-1. Simulation assumptions + +![Figure 4.2.5.1-2: CDF of serving beams RSRP. The plot shows the Cumulative Distribution Function (CDF) of RSRP values for different beam measurement periods. The x-axis is 'RSRP in dBm' ranging from -100 to -65. The y-axis is 'CDF' ranging from 0.0 to 1.0. Five curves are shown: 'Baseline, measurement period=1000ms' (blue solid line), 'Baseline, measurement period=500ms' (orange solid line), 'Baseline, measurement period=50ms' (green solid line), 'AI/ML-based, measurement period=1000ms' (red dashed line), and 'Ideal' (purple dotted line). The 'Ideal' and 'AI/ML-based' curves are nearly identical and show the highest RSRP values. The 'Baseline' curves show a significant degradation in RSRP as the measurement period increases from 50ms to 1000ms.](ff56d24cdf3b4a15fa448cc23bc9fe4e_img.jpg) + +Figure 4.2.5.1-2: CDF of serving beams RSRP. The plot shows the Cumulative Distribution Function (CDF) of RSRP values for different beam measurement periods. The x-axis is 'RSRP in dBm' ranging from -100 to -65. The y-axis is 'CDF' ranging from 0.0 to 1.0. Five curves are shown: 'Baseline, measurement period=1000ms' (blue solid line), 'Baseline, measurement period=500ms' (orange solid line), 'Baseline, measurement period=50ms' (green solid line), 'AI/ML-based, measurement period=1000ms' (red dashed line), and 'Ideal' (purple dotted line). The 'Ideal' and 'AI/ML-based' curves are nearly identical and show the highest RSRP values. The 'Baseline' curves show a significant degradation in RSRP as the measurement period increases from 50ms to 1000ms. + +**Figure 4.2.5.1-2. CDF of serving beams RSRP** + +The simulation result in Figure 4.2.5.1-2 shows the CDF curves of serving beams' RSRP for the different beam measurement periods. It can be seen that the conventional beam switching solution (indicated by "Baseline") heavily rely on the frequent beam measurement reports and the quality of selected beams are severely degraded according to the increase of measurement period. On the other hand, the AI/ML-based beam switching solution can predict the optimal beam with high accuracy only based on the historical beam measurement reports. By comparing the performance of these two solutions, it shows that the AI/ML-based solution can achieve near-optimal beam tracking performance under the condition of beam measurement period of 1000 ms, while the conventional solution requires the beam measurement period of 50 ms. The signaling overhead of beam measurement in the AI/ML-based solution is reduced by as much as 95% compared to the conventional solution. + +It is worth noting that the performance of simulated AI/ML-based solution do not sensitive to the latency introduced by E2 interface and/or E2-nodes/RIC processing time because the solution does not rely on very fast control loop. + +# 5 Non-GoB Beamforming + +## 5.1 Overview + +Non-GoB Beamforming, unlike GoB beamforming, does not rely on predefined beam sets, instead beam weights are determined in real-time at the BS in response to channel measurements, offering the potential for optimum beam patterns to be determined. For downlink, this approach relies on reciprocity in the channel and is therefore primarily aimed at TDD systems. How well the system performs in practice depends on several factors including choice of beamforming algorithm, the channel conditions between BS and UE and the configuration of reference signals. The O-RAN architecture offer opportunities to improve the beamforming performance by utilizing both Non-RT RIC and Near-RT RIC to support intelligent optimization of the Non-GoB beamforming configuration. + +## 5.2 Solution 1: AI/ML-assisted non-GoB Optimization + +### 5.2.1 Problem Statement and Value Proposition + +Non- Grid of Beams (non-GoB) beamforming approaches are an important class of beamforming algorithms for 5G mMIMO deployments, especially for fully digital, but also potentially for hybrid analog/digital, implementations in sub-6GHz frequency bands. Typically Sounding Reference Symbol (SRS) based approaches are used, which rely on uplink/downlink correspondence, where uplink and downlink beam weights are computed “on the fly” in the O-DU / gNB based on channel measurements made using SRS, rather than selecting from a set of predefined beams. The calculated weights are transferred from O-DU / gNB to the O-RU using existing fronthaul mechanisms. SRS based beamforming is particularly attractive for massive MIMO arrays because accurate channel state information can be obtained at the gNB with potentially less overhead in the DL or UL channels. gNB uplink SRS measurements generally have no quantization loss associated with reduction of over the air signaling and are faster availability for downlink adaptation since measurement is done in gNB. On the other hand, SRS measurements might not always be recently available (due to SRS periodicity and/or limited bandwidth), or reliable, especially towards cell edge since the UE transmit power in the uplink is limited. + +It should be noted that non-GoB algorithms are not standardized, instead these are vendor-specific proprietary algorithms. In addition, multiple algorithm modes or options may be implemented, where some modes may be more suited to particular conditions of the wireless channel, UE location/mobility, interference conditions, or to particular 3GPP configuration options such as SRS periodicity. Examples of beamforming modes include but are not limited to: the use of different SRS channel estimation algorithms; different weight calculation approaches (for example matched filter, Eigen, Zero-forcing beamforming); and different time or frequency granularity. + +Non-GoB beamforming may be applicable to multiple MIMO modes (SISO, SU-MIMO or MU-MIMO) on the downlink or uplink data channels (PDSCH/PUSCH). GoB beamforming will be used for other channels and may also be used for data channels in some cases where, for example, SRS measurement quality is poor. + +The problem statement is therefore how a 3rd-party xApp may provide intelligent control over multiple supported non-GoB beamforming modes in order to recommend a preferred mode to a gNB / O-DU as a function of channel conditions, UE location, interference conditions, etc. + +### 5.2.2 Architecture/Deployment Options + +#### 5.2.2.1 Option 1 + +It is assumed in this description that SMO/Non-RT RIC is responsible for obtaining beamforming configuration information from the gNB / O-DU, and for model training, and model deployment of the xApp to the near-RT RIC. The near-RT RIC performs model inference and provides control messages to the gNB / O-DU. AI/ML-enabled control of non-GoB beamforming configuration options is performed in the xApp to optimize a measure of performance (for example UE throughput), given UE/cell conditions. It should be noted that the low-latency beamforming weight calculation loop still resides in DU. xApp sits outside/above this loop and recommends configuration on a slower basis than the weight calculation loop. + +Referring to Figure 5.2.2.1-1, non-RT RIC first requests a report of supported beamforming configurations in the O-DU (referred to as “non-GoB mMIMO Config” in the diagram), and O-DU provides the requested report for the supported modes. This is done using the O1 interface, via SMO “Collection & Control” function, since non-RT does not terminate O1. + +The reported information could be as simple as the number of modes supported (=N). The modes are defined by the gNB / O-DU vendor. Optionally, there could be additional information provided, such as the circumstances in which use of each of the N modes is considered (by the gNB / O-DU) to be suitable (for example low or high mobility, low, medium or high SNR on (for example) SRS), which is illustrated in Table 5.2.2.1-1. + +| Mode ID | UL or DL | SNR range
(low/med/high) | UE Mobility
(stationary/low/high) | +|---------|----------|-----------------------------|--------------------------------------| +| 0 | | | | +| 1 | | | | +| 2 | | | | +| : | | | | +| N-1 | | | | + +**Table 5.2.2.1-1.** + +GoB-based approaches could be included as supported modes, thus enabling switch between non-GoB and GoB operation where conditions favor GoB (for example at cell-edge). + +Next, the Data Collection phase is entered, where non-RT RIC requests data collection from O-DU, again using O1 via the “Collection and Control” function. The O-DU responds with measurements over O1, such as SINR, the measurements being associated with each of the N beamforming modes (labelled “associated non-GoB mMIMO config” in the diagram). Specific measurements defined in 3GPP 28.522 may be re-used, for example, for downlink operation: Average DL UE throughput in gNB; Wideband CQI distribution; RSRQ measurement; RSRP measurement; SINR measurement. Information related to 3GPP configuration, such as SRS periodicity, is also reported. + +During the data collection phase, enrichment data, such as information related to UE location and mobility, may also be collected from an Application Server. The non-RT RIC associates enrichment data with the corresponding O-DU measurements, such that both are available for each UE. + +In the next step, the non-RT RIC trains AI/ML model(s) which will be used to predict relative performance between the N modes (or simply to predict the best mode) and deploys the trained models in xApp to near-RT RIC (over O1 or O2 – to be determined by O-RAN). + +Finally, models may be re-trained and re-deployed based on updated measurements sent between O-DU and non-RT RIC (via the “Collection and Control” entity) and on updated enrichment information. + +``` + +1 @startuml +2 skinparam ParticipantPadding 5 +3 skinparam BoxPadding 10 +4 skinparam defaultFontSize 12 +5 +6 Box "Service Management and Orchestration" #gold +7 Participant "Collection & Control" as smo +8 Participant "Non-RT RIC" as non +9 End box +10 +11 Box "O-RAN" #lightpink +12 Participant near as "Near-RT RIC" +13 Participant ran as "O-DU" +14 End box +15 +16 Box "External" #lightcyan +17 Participant "Application Server" as app +18 End box +19 +20 group Non-GoB mMIMO Configuration Report +21 non --> smo : Request non-GoB mMIMO Config +22 smo --> ran : <<01>> Request non-GoB mMIMO Config +23 ran --> smo : <<01>> Report non-GoB mMIMO Config +24 smo --> non : Report non-GoB mMIMO Config +25 end +26 +27 group Data Collection +28 non --> smo : Request Training Data Collection +29 smo --> ran : Non-GoB mMIMO Training Measurement Configuration +30 ran --> smo : <<01>> Data collection (measurements with associated non-GoB mMIMO config) +31 app --> smo : Enrichment data collection (location/mobility) +32 smo --> non : Retrieval of collected data +33 end +34 +35 group ML workflow +36 non -> non : Association of Enrichment data with O-DU Measurements +37 non -> non : Training of ML models +38 non -> near: <<01>> or <<02>> Deploy AI/ML models +39 end +40 +41 group Performance evaluation and optimization +42 ran --> smo : <<01>> Data collection (measurements with associated non-GoB mMIMO config) +43 app --> smo : Enrichment data collection (location/mobility) +44 smo -> non : Data retrieval of RAN +45 non -> non : Performance monitoring & evaluation +46 non -> non : Model re-training/update +47 non -> near: <<01>> or <<02>> Update AI/ML models +48 end +49 @enduml + +``` + +![Sequence diagram showing the interaction between Service Management and Orchestration, O-RAN (Near-RT RIC, O-DU), and External (Application Server) for Configuration Report, AI/ML training and deployment.](65c52ea6fe23749d831db7eb309cd36f_img.jpg) + +The diagram illustrates the sequence of operations for Configuration Report, AI/ML training and deployment across three main entities: Service Management and Orchestration (SMO), O-RAN, and External (Application Server). + +**Service Management and Orchestration (SMO):** Contains 'Collection & Control' and 'Non-RT RIC' components. + +**O-RAN:** Contains 'Near-RT RIC' and 'O-DU' components. + +**External:** Contains 'Application Server' component. + +**Sequence of Operations:** + +- Non-GoB mMIMO Configuration Report:** + - Request non-GoB mMIMO Config (SMO to O-RAN) + - <> Request non-GoB mMIMO Config (O-RAN to SMO) + - <> Report non-GoB mMIMO Config (O-RAN to SMO) + - Report non-GoB mMIMO Config (SMO to O-RAN) +- Data Collection:** + - Request Training Data Collection (SMO to O-RAN) + - Non-GoB mMIMO Training Measurement Configuration (SMO to O-RAN) + - <> Data collection (measurements with associated non-GoB mMIMO config) (O-RAN to SMO) + - Enrichment data collection (location/mobility) (SMO to O-RAN) + - Retrieval of collected data (O-RAN to SMO) +- ML workflow:** + - Association of Enrichment data with O-DU Measurements (O-RAN to SMO) + - Training of ML models (SMO to O-RAN) + - <> or <> Deploy AI/ML models (SMO to O-RAN) +- Performance evaluation and optimization:** + - <> Data collection (measurements with associated non-GoB mMIMO config) (O-RAN to SMO) + - Enrichment data collection (location/mobility) (SMO to O-RAN) + - Data retrieval of RAN (O-RAN to SMO) + - Performance monitoring & evaluation (SMO to O-RAN) + - Model re-training/update (SMO to O-RAN) + - <> or <> Update AI/ML models (SMO to O-RAN) + +Sequence diagram showing the interaction between Service Management and Orchestration, O-RAN (Near-RT RIC, O-DU), and External (Application Server) for Configuration Report, AI/ML training and deployment. + +Figure 5.2.2.1-1. Configuration Report, AI/ML training and deployment. + +Referring to Figure 5.2.2.1-2, the near-RT RIC xApp performs AI/ML model inference using models previously deployed from non-RT RIC. Enrichment data is provided from non-RT RIC via A1, and measurements (such as SINR) and SRS configuration information is obtained from O-DU over E2. Association of measurements and enrichment data is performed by near-RT RIC. The recommended beamforming mode(s) (out of N) is provided from near-RT to O-DU over E2 (“mMIMO non-GoB control or policy message” in the diagram). The O-DU can then configure the non-GoB beamforming algorithm taking account of the mode received from near-RT RIC. In exceptional circumstances in case the O-DU is not able to apply the signaled mode then a failure indication could be returned by the O-DU. The xApp may maintain statistics about success/failure rates. Optionally, the beamforming mode recommendation may be selected by the near-RT RIC in order to improve the training data set, which could be used, for example, in the case of reinforcement learning based implementations. + +``` + +1 @startuml +2 skinparam ParticipantPadding 5 +3 skinparam BoxPadding 10 +4 skinparam defaultFontSize 12 +5 +6 Box "Service Management and Orchestration" #gold +7 Participant "Collection & Control" as smo +8 Participant "Non-RT RIC" as non +9 End box +10 +11 Box "O-RAN" #lightpink +12 Participant near as "Near-RT RIC" +13 Participant ran as "O-DU" +14 End box +15 +16 Box "External" #lightcyan +17 Participant "Application Server" as app +18 End box +19 +20 app --> smo : Enrichment data collection (location/mobility) +21 smo --> non : Retrieval of collected data +22 non --> near : <> Enrichment data (location/mobility) +23 +24 group E2 control & Policy +25 near --> ran : <> Non-GoB mMIMO Measurement Configuration +26 ran --> near : <> Data collection (measurements) +27 near -> near: Association of Enrichment data with O-DU Measurements +28 near -> near : ML model inference +29 near -> near : E2 control or policy generation +30 near -> ran: <> mMIMO non-GoB control or policy message +31 end +32 +33 @enduml + +``` + +![Sequence diagram illustrating AI/ML Inference across three domains: Service Management and Orchestration (SMO), O-RAN, and External. SMO contains Collection & Control and Non-RT RIC. O-RAN contains Near-RT RIC and O-DU. External contains Application Server. The diagram shows data flow for enrichment data collection, retrieval, and E2 control & policy generation.](449108cc71696dd2eb0b96bbe0da6ea7_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management and Orchestration + participant O_RAN as O-RAN + participant External as External + + Note over SMO: Collection & Control, Non-RT RIC + Note over O_RAN: Near-RT RIC, O-DU + Note over External: Application Server + + External->>SMO: Enrichment data collection (location/mobility) + SMO->>SMO: Retrieval of collected data + SMO->>O_RAN: <> Enrichment data (location/mobility) + Note over O_RAN: E2 control & Policy + O_RAN->>O_RAN: <> Non-GoB mMIMO Measurement Configuration + O_RAN->>O_RAN: <> Data collection (measurements) + O_RAN->>O_RAN: Association of Enrichment data with O-DU Measurements + O_RAN->>O_RAN: ML model inference + O_RAN->>O_RAN: E2 control or policy generation + O_RAN->>O_RAN: <> mMIMO non-GoB control or policy message + +``` + +Sequence diagram illustrating AI/ML Inference across three domains: Service Management and Orchestration (SMO), O-RAN, and External. SMO contains Collection & Control and Non-RT RIC. O-RAN contains Near-RT RIC and O-DU. External contains Application Server. The diagram shows data flow for enrichment data collection, retrieval, and E2 control & policy generation. + +Figure 5.2.2.1-2. AI/ML Inference + +##### 1 Requirements + +2 Required data: + +3 Initialization: + +| Input/Output Data | | | | | | | +|-------------------|-------------------|----------------------------------------------|-------|---------------------|-------------------------|------------------------| +| Interface | Source → Target | Name/Description | Units | Config. granularity | Period, | New or existing config | +| O1 via SMO | Non-RT RIC → O-DU | Supported Non-GoB beamforming modes Request | - | | Initialization, per gNB | New | +| O1 via SMO | O-DU → Non-RT RIC | Supported Non-GoB beamforming modes Response | - | | Initialization, per gNB | New | + +4 Table 5.2.2.1-2. + +5 + +6 Training configuration: + +| Input/Output Data | | | | | | | +|-------------------|-------------------|------------------------|-------|-----------------------------|--|------------------------| +| Interface | Source → Target | Name/Description | Units | Config. Period, granularity | | New or existing config | +| O1 via SMO | Non-RT RIC → O-DU | Training configuration | * | ~ hours/days, per gNB | | New | + +7 Table 5.2.2.1-3. + +8 Note\*: to be elaborated during normative phase. One example is a schedule for the use of each beamforming mode for +9 use during the training phase. + +10 + +11 + +1 Measurements/reports from E2 Nodes (training phase): + +| Input Data | | | | | | +|------------|-------------------|--------------------------------------------------------------------|--------------|-------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------| +| Interface | Source Target → | Name/Description | Units | Reporting Period, granularity | New or existing measurement, Existing Specification (Section) | +| O1 via SMO | O-DU → Non-RT RIC | Average DL UE throughput in gNB with associated non-GoB mMIMO mode | Kb/s + index | (non real-time for training) | Existing definition 3GPP TS 28.552 (Sec. 5.1.1.3.1)
Require new per-UE reporting. New component is associated non-GoB mMIMO mode index | +| O1 via SMO | O-DU → Non-RT RIC | Average UL UE throughput in gNB with associated non-GoB mMIMO mode | Kb/s + index | (non real-time for training) | Existing definition 3GPP TS 28.552 (Sec. 5.1.1.3.3)
Require new per-UE reporting. New component is associated non-GoB mMIMO mode index | +| O1 via SMO | O-DU → Non-RT RIC | RSRQ L1 measurement (based on Synchronization Signal) | dB | (non real-time for training) | Existing definition 3GPP TS 38.133 (Sec. 10.1.11)
3GPP TS 38.215 (Sec. 5.1.3)
New reporting | +| O1 via SMO | O-DU → Non-RT RIC | RSRP L1 measurement (based on Synchronization Signal) | dBm | (non real-time for training) | Existing definition 3GPP TS 38.133 (Sec. 10.1.6)
3GPP TS 38.215 (Sec. 5.1.1)
New reporting | +| O1 via SMO | O-DU → Non-RT RIC | DL L1 SINR measurement (based on Synchronization Signal) | dB | (non real-time for training) | Existing definition 3GPP TS 38.133 (Sec. 10.1.16)
3GPP TS 38.215 (Sec. 5.1.5)
New reporting | +| O1 via SMO | O-DU → Non-RT RIC | UL SRS RSRP measurement | dBm | (non real-time for training) | Existing definition 3GPP TS 38.133 (Sec. 13.3.1)
3GPP TS 38.215 (Sec. 5.2.5)
New reporting | +| O1 via SMO | O-DU → Non-RT RIC | SRS configuration periodicity | slots | (non real-time for training) | Existing definition 3GPP TS 38.331 (Sec. 6.3.2 “SRS-Config->periodicityAndOffset”)
New reporting | + +Table 5.2.2.1-4. + +1 Measurements/reports from E2 Nodes (inference phase): + +| Input Data | | | | | | +|------------|--------------------|----------------------------------------------------------|-------|-------------------------------|--------------------------------------------------------------------------------------------------| +| Interface | Source Target → | Name/Description | Units | Reporting Period, granularity | New or existing measurement, Existing Specification (Section) | +| E2 | O-DU → Near-RT RIC | RSRQ L1 measurement (based on Synchronization Signal) | dB | ~per N x 100ms, per UE | Existing definition 3GPP TS 38.133 (Sec. 10.1.11) 3GPP TS 38.215 (Sec. 5.1.3) New reporting | +| E2 | O-DU → Near-RT RIC | RSRP L1 measurement (based on Synchronization Signal) | dBm | ~per N x 100ms, per UE | Existing definition 3GPP TS 38.133 (Sec. 10.1.6) 3GPP TS 38.215 (Sec. 5.1.1) New reporting | +| E2 | O-DU → Near-RT RIC | DL L1 SINR measurement (based on Synchronization Signal) | dB | ~per N x 100ms, per UE | Existing definition 3GPP TS 38.133 (Sec. 10.1.16) 3GPP TS 38.215 (Sec. 5.1.5) New reporting | +| E2 | O-DU → Near-RT RIC | UL SRS RSRP measurement | dBm | ~per N x 100ms, per UE | Existing definition 3GPP TS 38.133 (Sec. 13.3.1) 3GPP TS 38.215 (Sec. 5.2.5) New reporting | +| E2 | O-DU → Near-RT RIC | SRS configuration periodicity | slots | ~per N x 100ms, per UE | Existing definition 3GPP TS 38.331 (Sec. 6.3.2 “SRS-Config->periodicityAndOffset”) New reporting | + +2 **Table 5.2.2.1-5.** + +3 Whether additional filtering of L1 measurements is required in O-DU is for further study during the normative phase. + +4 +5 Enrichment data from Application Server: + +- 6 1. UE mobility (speed and direction) +- 7 2. UE location +- 8 3. The time granularity is an integer multiple of [1] second. + +Output Signalling towards E2 Nodes: + +| Output Data | | | | | | | +|-------------|--------------------|---|---------------------------------------------------|-------|-----------------------------|------------------------| +| Interface | Source Target | → | Name/Description | Units | Config. Period, granularity | New or existing config | +| E2 | Near-RT RIC → O-DU | | Non-GoB control/policy (non-GoB beamforming mode) | index | ~per N x 100ms, per UE | New | + +Table 5.2.2.1-6. + +ORAN Entity roles: + +- 1) SMO + - a) Support O1-based Request and Report of O-DU supported non-GoB mMIMO configurations (beamforming modes) + - b) Support O1-based Configuration and Collection of Training Measurement data / SRS configuration from O-DU + - c) Enrichment Data Collection +- 2) Non-RT RIC + - a) Issue Request and receive Report of O-DU non-GoB beamforming modes from O-DU through SMO + - b) Configuration and retrieval of Training Measurement Data from O-DU + - c) Enrichment Data Retrieval + - d) Perform association of Training Measurement Data and Enrichment Information + - e) Model training/re-training + - f) Model xApp deployment/re-deployment + - g) Send Enrichment Data to near-RT RIC over A1 + - h) Performance monitoring and evaluation +- 3) Near-RT RIC + - a) Retrieval of Enrichment Data over A1 + - b) Retrieval of ML Models from the Non-RT RIC + - c) Retrieval of O-DU measurements/SRS configuration over E2 + - d) Association of E2 Measurement Data and Enrichment Data + - e) Model inference by xApp + - f) Send non-GoB control/policy (recommendation of non-GoB beamforming mode) to O-DU over E2 +- 4) E2 nodes + - a) Respond to O1-based Request by sending Report of O-DU supported non-GoB mMIMO configurations (beamforming modes) over O1 + - b) Respond to O1-based Configuration and Report of Training Measurement data / SRS configuration over O1 + - c) Collect and report measurements (with associated beamforming mode)/SRS configuration over E2 to Near-RT RIC + - d) Apply non-GoB control/policy (non-GoB beamforming mode) received over E2 + +### 5.2.3 Impact Analysis on O-RAN Working Groups + +*Editor's note: This is an initial impact analysis as part of the WG1 UCTG work on mMIMO. The intention is to estimate the expected standardization effort within the O-RAN working groups. It is up to the WGs to decide how the mMIMO functionality should be specified in specifications of each WG.* + +#### WG2 (Non-RT RIC, A1) Impact + +- O-RAN.WG2.Use-Case-Requirements + - If seen as beneficial, add new use case: Massive MIMO non-Grid-of-Beams Beamforming Optimization based on agreements from pre-normative phase +- O-RAN.WG2.A1 TD + - Support exchange of relevant Enrichment Data from non-RT to near-RT RIC + +#### WG3 (Near-RT RIC, E2) Impact + +- O-RAN.WG3.UCR + - Add new use case: Massive MIMO non-Grid-of-Beams Beamforming Optimization based on agreements from pre-normative phase +- O-RAN.WG3.E2SM-KPM + - Option 1: If UE specific L1/2 measurement reporting is added to the 3GPP specification (e.g. 3GPP TS37.320 section 5.4.1.), E2 will refer to 3GPP spec and there will be minor or no impact on E2SM-KPM specifications. + - Option 2: If UE specific L1/2 measurement reporting is not added to the 3GPP specifications, “O-RAN specific” measurements need to be added to E2SM-KPM. Considering that measurement definitions exist in 3GPP the effort will be minor, noting that E2SM-KPM has already extended the definitions of measurement counters in TS 28.522 to be able to be retrieved per UE level from RAN node. + - Note that there will likely be some commonality with other use cases +- O-RAN.WG3.E2SM-RC or any other suitable E2SM + - Add new Non-GoB control/policy (non-GoB beamforming mode) in direction near-RT RIC to O-DU + +#### WG5 (O1) Impact + +- O-RAN.WG5.MP O1 Interface specification for O-DU + - Option 1: If UE specific L1/2 measurement reporting is added to the 3GPP specification (e.g. 3GPP TS37.320 section 5.4.1.), O1 could refer to 3GPP spec and there could be very limited or no impact on O1 specifications. + - Option 2: If UE specific L1/2 measurement reporting is not added to or re-used from the 3GPP specifications, O-RAN would add reporting of these as an extension of O1. As the measurement definitions already exist, the impact will be moderate. + - Similarly, initialization/training configuration might also be specified in 3GPP and/or in O-RAN (using type “O-RAN WG5 modified model based on 3GPP SA5” as defined in chapter 10). + - Supported Non-GoB beamforming modes Request in direction SMO to O-DU + - Supported Non-GoB beamforming modes Response in direction O-DU to SMO + - Training configuration in direction SMO to O-DU (exact definition is FFS, one example being a schedule for the application of different beamforming modes during training phase). + +Summary: The impact on O-RAN E2 specification is small. For O1, the impact on O-RAN specification is small in case measurement reporting/configuration management are specified in 3GPP and referred to by O-RAN specifications, and moderate if the reporting of new required per-UE L1/L2 measurements and related configuration management are specified in O-RAN. + +### 5.2.4 Relation and Impact on 3GPP Specification + +Per-UE L1/2 measurement reporting might be added to the existing 3GPP MDT framework or might be added in a new AI/ML Data Collection framework currently discussed in 3GPP. + +The 3GPP MDT framework is defined in 3GPP TS37.320 for UMTS, LTE and NG Radio Access. There are UE specific signal measurements defined with reference to 3GPP TS38.215. The handling and management of MDT traces are specified in 3GPP TS32.421, TS32.422, TS32.423 as well as TS32.445, TS32.446 etc. + +In terms of a new AI/ML motivated measurement framework, related work is already underway in 3GPP RAN3 and SA5, for example in the Study on enhancement for Data Collection for NR and EN-DC, which is being documented in 37.817. Further work might be considered, for example as proposed in the recent Study Item proposal (S5-215397, “New SID Study on measurement data collection to support RAN intelligence”). Support of new reporting of UE-specific L1/2 measurements in direction O-DU to non- RT RIC and near-RT RIC is therefore FFS. + +In terms of configuration/control, it is FFS whether 3GPP will specify the following: + +- Supported Non-GoB beamforming modes Request in direction SMO to O-DU +- Supported Non-GoB beamforming modes Response in direction O-DU to SMO +- Training configuration in direction SMO to O-DU + +The current working assumption is that these will first be specified by O-RAN WG5 in which case there is no dependency on 3GPP progress (noting however that additional instances are expected to be proposed to 3GPP for having alignment of the information models between 3GPP and O-RAN WG5). + +### 5.2.5 Feasibility and Gain/Complexity Analysis + +#### 5.2.5.1 Simulation Results + +Simulation results are provided for the assumptions shown in Table 5.2.5.1-1. + +| Parameter | Description | +|--------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------| +| Cell | Single cell, 120-degree sector, 300m radius | +| Channel model | Based on 3GPP non-line of sight CDL, with path gains and angles computed for random spatial placement of scatterers and static blockers. | +| Pathloss | Macro model per 3GPP TR 36.931 | +| Angular spread at BS | ~25 degrees | +| MIMO Mode | Downlink, SU-MIMO, 2 layers fixed (i.e. no adaptation of layers, pre-coding, no scheduling, etc.) | +| Beamforming modes | Mode 0: SRS-based
Mode 1: GoB-based | +| Relative SNR DL PDSCH to UL SRS channel estimate | +10 dB, takes account of relative noise figures and output powers between gNB and UE (UL Transmit Power Control not modelled) | +| gNB antenna array | 32 elements x 2 polarization panel antenna | +| UE antenna array | 1 element x 2 polarizations | +| SRS periodicity | 8 slots | +| Carrier Frequency | 3.5 GHz | +| Output metric | Simulated channel capacity | + +**Table 5.2.5.1-1. Simulation Assumptions** + +Simulated downlink capacity for one example randomly dropped cell is shown for low (1km/h) and high (120 km/h) mobility scenarios, in the heatmaps in Figure 5.2.5.1-1, and in CDFs of relative throughputs in Figure 5.2.5.1-2 and in Figure 5.2.5.1-3. + +![Heatmaps for low mobility scenario showing PDSCH throughput for mode 0 and mode 1.](bb10c312303fbe213c5faa8f9ced1f6e_img.jpg) + +Figure 5.2.5.1-1 (a) displays two heatmaps for low mobility (1 km/h) showing simulated downlink capacity (PDSCH throughput) for mode 0 and mode 1. The x and y axes represent distance in meters (m), ranging from -300 to 300. The color scale indicates throughput, with brighter colors (yellow/green) representing higher values and darker colors (blue) representing lower values. Both modes show a similar pattern of high throughput (yellow/green) concentrated in the center of the cell, with mode 0 showing slightly higher throughput than mode 1. + +Heatmaps for low mobility scenario showing PDSCH throughput for mode 0 and mode 1. + +a) Low mobility + +![Heatmaps for high mobility scenario showing PDSCH throughput for mode 0 and mode 1.](1fd5bd1eb65f714d27c57dccebbd9034_img.jpg) + +Figure 5.2.5.1-1 (b) displays two heatmaps for high mobility (120 km/h) showing simulated downlink capacity (PDSCH throughput) for mode 0 and mode 1. The x and y axes represent distance in meters (m), ranging from -300 to 300. The color scale indicates throughput, with brighter colors (yellow/green) representing higher values and darker colors (blue) representing lower values. Both modes show a similar pattern of high throughput (yellow/green) concentrated in the center of the cell, with mode 0 showing slightly higher throughput than mode 1. + +Heatmaps for high mobility scenario showing PDSCH throughput for mode 0 and mode 1. + +b) High mobility + +**Figure 5.2.5.1-1. Heatmaps. Brighter colors represent higher throughputs.** + +![Figure 5.2.5.1-2: Relative PDSCH throughput CDF, low mobility. The graph shows CDF (%) on the y-axis (0 to 100) versus Relative throughput on the x-axis (0 to 1). Two curves are plotted: mode 0 (red) and mode 1 (black). Mode 1 shows higher throughput than mode 0. The title is '1 km/h, SU-MIMO 2-layer'.](8fe1529bf1222170bff630d1cc2ca08f_img.jpg) + +1 km/h, SU-MIMO 2-layer + +CDF (%) + +Relative throughput + +mode 0 +mode 1 + +Figure 5.2.5.1-2: Relative PDSCH throughput CDF, low mobility. The graph shows CDF (%) on the y-axis (0 to 100) versus Relative throughput on the x-axis (0 to 1). Two curves are plotted: mode 0 (red) and mode 1 (black). Mode 1 shows higher throughput than mode 0. The title is '1 km/h, SU-MIMO 2-layer'. + +**Figure 5.2.5.1-2. Relative PDSCH throughput CDF, low mobility.** + +![Figure 5.2.5.1-3: Relative PDSCH throughput CDF, low mobility. The graph shows CDF (%) on the y-axis (0 to 100) versus Relative throughput on the x-axis (0 to 1). Two curves are plotted: mode 0 (red) and mode 1 (black). Mode 1 shows higher throughput than mode 0. The title is '120 km/h, SU-MIMO 2-layer'.](6862f166f54224feff37422470ad1559_img.jpg) + +120 km/h, SU-MIMO 2-layer + +CDF (%) + +Relative throughput + +mode 0 +mode 1 + +Figure 5.2.5.1-3: Relative PDSCH throughput CDF, low mobility. The graph shows CDF (%) on the y-axis (0 to 100) versus Relative throughput on the x-axis (0 to 1). Two curves are plotted: mode 0 (red) and mode 1 (black). Mode 1 shows higher throughput than mode 0. The title is '120 km/h, SU-MIMO 2-layer'. + +**Figure 5.2.5.1-3. Relative PDSCH throughput CDF, low mobility.** + +The achieved throughput depends on UE location and mobility. The throughput pattern is not uniform across angles due to random placement of scatterers and blockers within the cell. + +Mode 0 performs best towards the center of the cell and mode 1 towards cell edge, however the cross-over point depends on mobility, with mode 0 performing worse in the high mobility scenario. + +Table 5.2.5.1-2 and Table 5.2.5.1-3 compare average, 5-percentile and 95-percentile relative throughputs for PDSCH for modes 0 and 1, and for an ideal intelligent mode selection, for low and high mobility cases respectively. The opportunity for intelligent mode selection is a substantial increase in throughput relative to either a fixed configuration of mode-0 or mode-1. + +It is worth noting that these results are for a single fixed assumed SRS periodicity (8 slots). The cross-over points between mode 0 and mode 1 would also likely have a dependency on SRS periodicity. + +| Mode | Relative
Av. cell
throughput
% | Relative 5-
percentile
cell
throughput
% | Relative 95-
percentile
cell
throughput
% | +|---------------------------------------------|-----------------------------------------|------------------------------------------------------|-------------------------------------------------------| +| 0 | 100.0000 | 100.0000 | 100.0000 | +| 1 | 72.8874 | 159.9304 | 55.7866 | +| Ideal intelligent
mode selection
| 102.2254 | 159.9304 | 100.0000 | + +**Table 5.2.5.1-2. Average, 5-percentile and 95-percentile relative PDSCH throughputs, low mobility** + +| Mode | Relative
Av. cell
throughput
% | Relative 5-
percentile
cell
throughput
% | Relative 95-
percentile
cell
throughput
% | +|---------------------------------------------|-----------------------------------------|------------------------------------------------------|-------------------------------------------------------| +| 0 | 100.0000 | 100.0000 | 100.0000 | +| 1 | 99.4713 | 241.0834 | 70.7448 | +| Ideal intelligent
mode selection
| 114.3104 | 241.0834 | 100.0000 | + +**Table 5.2.5.1-3. Average, 5-percentile and 95-percentile relative PDSCH throughputs, high mobility** + +The fixed configuration of a GoB and non-GoB SU-MIMO mode (mode-0 or mode-1) provides one example of the potential benefit of a MIMO mode switching algorithm. The actual gain might be impacted by various factors not considered in this simulation as described in Table 5.2.5.1-1. + +Although these initial simulation results do not include MU-MIMO scheduling or inter-cell interference, similar findings are expected for these conditions, some related simulated results can be found in [2] . One possibility, to be determined during the normative phase, is for beamforming mode control to be performed for multiple MIMO modes, for example, with one control for SU-MIMO, and one for MU-MIMO. + +# 6 MIMO DL Tx Power Optimization, MU-MIMO Pairing and MIMO mode selection + +## 6.1 Overview + +Massive MIMO holds promise in significantly increasing capacity in practical wireless network environments. Capacity can depend on the wireless network environment (e.g., user velocity, etc.) and the desired quality of the user wireless experience. In many practical cases, the capacity of the cell can be increased by, for example, proper choice of parallel user groups, etc. On the other hand, increased number of parallel users can incur increased inter-user interference which can reduce the user quality. In order to properly balance this trade off operators need fundamental observations (aka, “dials”) to assess the network environment and the user quality for both the uplink and the downlink. Further, to optimize the capacity vs. quality for a given cell for a given time and user distribution, the operator needs fundamental parameters to be changed (aka, “knobs”). The following sections will describe three relevant use-cases and list a number of dials and knobs that we believe constitute a fundamental set for observations and manipulation of massive MIMO systems for both Grid of Beams (GoB) and Reciprocity based implementations. + +To further optimize/automate the complex process, it is proposed that O-RAN interfaces be provided (dials and knobs) to enable a AI/ML model training and update, its inference, and finally the beam optimization to enhance the massive MIMO system performance observe and manipulate the massive MIMO system. + +## 6.2 MIMO optimization use-cases + +The use-cases described in the subsequent sections will show how dials and knobs (specifically referenced) can be used to optimize the three important use cases of downlink transmit power, MIMO pairing enhancement (user separability), and user MIMO mode selection (Mu-MIMO or Su-MIMO). Each use case will address the proposed solution, value proposition, use of specific dials and knobs, and where applicable the potential gains via analytical studies or simulation. + +### 6.2.1 Solution 1: Downlink Transmit power optimization + +#### 6.2.1.1 Problem Statement, Solution and Value Proposition + +For general downlink precoding, the downlink transmit power is usually evenly distributed across the UEs. However, depending on the UE separability and path loss deltas, this may result in good cell capacity at the expense of individual UE quality. This can be due to a number of issues such as cell edge UEs having general downlink SINR issues (even without Mu-MIMO), poor UE separability between cell edge UEs, and poor uplink SINR resulting in degraded SRS which are a few example issues. The result of these issues can be manifested by observations of very poor individual UE SINRs (either downlink, uplink, or both) when running in a Mu-MIMO mode. Therefore, although the capacity of the cell has been significantly increased, certain customer experiences may become unacceptable in this Mu-MIMO mode. + +The solution to the problem described above is to simply provide observations (“dials”) of UE performance in the form of periodic histograms of UE channel quality as well as the overall cell capacity in order to compute an optimal solution via AI/ML with control (knob) of the downlink minimum required SINR threshold to achieve a minimal UE quality requirement that is set by the operator. The minimum required SINR is a policy and thus doesn’t require real time AI/ML adjustment of transmit power directly but rather leaves this to the scheduler to adjust and optimize consistent with its numerous other priorities and requirements. This adjustment does not impact the normal iBLER (initial BLER) targets, or the CQI/MCS process of adapting the MCS to the UE indicated CQI. Since the received SINR will vary across UEs (see below) and even across PRBs due to frequency selective fading (where narrowband CQI is an option for operators) there is no explicit impact for PRBs. This concept can be extended to the uplink minimum SINR and can improve the + +uplink more in reciprocity Mu-MIMO modes since the performance in this mode is highly dependent on channel estimation accuracy which is directly influenced by the SRS quality. Performance in the uplink can be improved as shown in reference [3] when the channel quality increase can improve the interference rejection (gains are referenced in the performance section below). + +The value of this observability and adjustability allows the operator to optimize the trade-off between cell capacity and individual user/customer quality which is essential to provide the best customer experience. The trade-off, for example, can **reduce** a very high cell centre data rate (which would likely be unnoticeable for the user) to allow more power to be allocated to the cell edge user (who is noticing low throughput and large latencies) to improve the cell edge data rate situation. The gains to the cell edge occur when specifically, the SINR is so low (e.g., - 10 dB) such that the MCS is low that the spectral efficiency is not sufficient to support the minimum throughput requirements needed by the customer and thus the operator. Based on inputs from the AI/ML system, the scheduler can improve this undesirable situation by re-allocation of transmit power to meet minimum SINR requirements for these degraded users. Thus, the scheduler has a recommended policy that it may (or in special cases is not able to satisfy if UE buffer, latency, or other issues preclude) use as guidance for the scheduling of Mu-MIMO users. + +In summary, the target of this use case is to improve the downlink post-pairing SINR for MU-MIMO UE to improve cell edge performance and overall cell throughput. The output of this use case is the Minimum Downlink Post-pairing SINR Threshold for MU-MIMO UEs and provided as additional input to the L2 scheduler to support this optimization. The use case does not suggest any specific behaviour. It is left to scheduler implementation how this target is achieved. The relation of this parameter to the 5QI QoS throughput attributes of this UE is ffs. + +#### 6.2.1.2 Architecture/Deployment Options + +The non-RT RIC trains and updates the specific Downlink transmit power control and optimization AI/ML models. Figure 6.2.1.2-1 reflects the functional dependencies of the AI/ML implementation framework. The MU-MIMO DL power control (MPC) rAPP performs optimization required. As shown in Figure 6.2.1.2-1, the rApp uses O1 interface measurement data (via SMO exposed services over R1 interface) for training the ML model. The MPC rApp running in the non-RT RIC uses O1 interface measurement data to optimize minimum downlink SINR threshold for MU-MIMO users at the O-CU or O-DU (as applicable) over O1 interface (via SMO exposed services over R1 interface). + +The ML model driving the MPC rApp will utilize UE orthogonality and path loss delta data to understand the scenarios where there can be a set of UEs that have significantly degraded SINR, in addition to monitoring SINR from downlink CQI measurements. The output of the ML model will be a configuration recommendation for the minimum downlink SINR threshold for Mu-MIMO UEs. + +![High level architecture for MIMO power control use-case. The diagram shows a hierarchical structure: SMO (Service Management and Orchestration) at the top, containing Non-RT RIC (Non-Real Time RIC) and O1 services. Non-RT RIC includes AI/ML training and MPC rApp. SMO connects to Near-RT RIC (Near-Real Time RIC) via A1 interface. Near-RT RIC connects to O-CU/O-DU (Control User Plane / Data User Plane) via E2 interface. O-CU/O-DU connects to O-RU (Radio Unit) via FH M-Plane (F1-M). Data Collection is shown as a feedback loop from O-CU/O-DU to SMO via O1 interface.](3ee5821edf142c50f59bd5f56b68ad83_img.jpg) + +High level architecture for MIMO power control use-case. The diagram shows a hierarchical structure: SMO (Service Management and Orchestration) at the top, containing Non-RT RIC (Non-Real Time RIC) and O1 services. Non-RT RIC includes AI/ML training and MPC rApp. SMO connects to Near-RT RIC (Near-Real Time RIC) via A1 interface. Near-RT RIC connects to O-CU/O-DU (Control User Plane / Data User Plane) via E2 interface. O-CU/O-DU connects to O-RU (Radio Unit) via FH M-Plane (F1-M). Data Collection is shown as a feedback loop from O-CU/O-DU to SMO via O1 interface. + +Figure 6.2.1.2-1. High level architecture for MIMO power control use-case + +![Call Flow Diagram for MIMO power control use-case. The diagram is divided into four main sections: MIMO configuration data collection, MIMO performance data Collection, ML workflow, and MIMO monitoring and optimization. The participants are Collection & Control, Non-RT RIC, Near-RT RIC, O-DU, and O-RU. The flow is as follows: 1. Collection & Control requests MIMO configuration parameters from Non-RT RIC. 2. Non-RT RIC requests MIMO config from O-DU. 3. O-DU reports MIMO config to Near-RT RIC. 4. Non-RT RIC reports MIMO config to O-DU. 5. Non-RT RIC reports MIMO configuration parameters to Collection & Control. 6. Collection & Control requests MIMO performance data collection from Non-RT RIC. 7. Non-RT RIC requests MIMO performance measurement configuration from O-DU. 8. O-DU reports MIMO data collection to Near-RT RIC. 9. Non-RT RIC reports MIMO data collection to O-DU. 10. Non-RT RIC retrieves collected data from Collection & Control. 11. Training of ML models. 12. Deploy ML models. 13. O-DU reports data collection for inference and optimization to Near-RT RIC. 14. Non-RT RIC reports data collection for inference and optimization to O-DU. 15. Non-RT RIC reports data retrieval of RAN to Collection & Control. 16. Performance monitoring & evaluation. 17. Non-RT RIC reports updated MIMO configuration to Collection & Control. 18. Collection & Control applies MIMO configuration to O-DU. 19. O-DU applies MIMO configuration to O-RU.](b9d9a1e5ed688d0594b52d21a62c8168_img.jpg) + +Call Flow Diagram for MIMO power control use-case. The diagram is divided into four main sections: MIMO configuration data collection, MIMO performance data Collection, ML workflow, and MIMO monitoring and optimization. The participants are Collection & Control, Non-RT RIC, Near-RT RIC, O-DU, and O-RU. The flow is as follows: 1. Collection & Control requests MIMO configuration parameters from Non-RT RIC. 2. Non-RT RIC requests MIMO config from O-DU. 3. O-DU reports MIMO config to Near-RT RIC. 4. Non-RT RIC reports MIMO config to O-DU. 5. Non-RT RIC reports MIMO configuration parameters to Collection & Control. 6. Collection & Control requests MIMO performance data collection from Non-RT RIC. 7. Non-RT RIC requests MIMO performance measurement configuration from O-DU. 8. O-DU reports MIMO data collection to Near-RT RIC. 9. Non-RT RIC reports MIMO data collection to O-DU. 10. Non-RT RIC retrieves collected data from Collection & Control. 11. Training of ML models. 12. Deploy ML models. 13. O-DU reports data collection for inference and optimization to Near-RT RIC. 14. Non-RT RIC reports data collection for inference and optimization to O-DU. 15. Non-RT RIC reports data retrieval of RAN to Collection & Control. 16. Performance monitoring & evaluation. 17. Non-RT RIC reports updated MIMO configuration to Collection & Control. 18. Collection & Control applies MIMO configuration to O-DU. 19. O-DU applies MIMO configuration to O-RU. + +Figure 6.2.1.2-2. Call Flow Diagram for MIMO power control use-case + +In the call flow in Figure 6.2.1.2-2, the rApp can request the current MIMO configuration (e.g. downlink SINR threshold values) (steps 2-5), as well as current network measurements and KPIs (steps 7-10). The R1 interface is used by the rApp to communicate these requests to SMO, which in turn coordinates the collection via O1 interface. The AI/ML model that is part of the rApp will use the measurements to evaluate the current capacity and UE performance and if required, will generate a recommendation to update the SINR configuration (step 16). This new recommendation is sent to SMO via R1 interface, and finally communicated to the O-DU via O1 interface (step 18). + +##### Requirements + +This section outlines the required measurement data (dials) that form the input of the optimization app and also the output control/configuration (knobs) that are to be fine-tuned to achieve the desired optimization objective. + +| Interface | Source
→
Target | Description | Units | Measurement Period | Reference | New or existing measurement/reporting specification | +|-----------|-------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------|--------------------|-----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Paired UE Orthogonality Factor (min UE pair Cross Correlation Coefficient [0,1] for each K number of parallel UEs ) histogram
(the cross correlation coefficient is defined as $E\{hh^*\}/E\{ h ^2\}$ where h = channel estimate for a given UE) | dB
(0,...,-50) for K values | 1 .. 15 min. | [Dial09] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Path Loss Delta distribution across all Mu-MIMO UEs (percent vs. < 1 dB, < 3 dB, < 5 dB, < 10 dB, < 15 dB, < 20 dB, < 30 dB, > 30 dB)
(the path loss may be estimated by the downlink TX power minus the RSRP all normalized to the SCS tone bandwidth or be PHR reporting) | Percent | 1 .. 15 min. | [Dial10] | New measurement definition
New measurement reporting | + +**Table 6.2.1.2-1. UE spatial separability dials** + +| | | | | | | | +|----|-------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------|----------|-----------------------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Downlink CQI Report histogram (one CQI histogram (percent use vs. CQI index) for each number of Mu-MIMO UEs in parallel (e.g., 1,2,3,..K) See section 0 (GoB) for other use cases. | Percent | 1 .. 15 min. | [Dial18] | Measurement definition in 3GPP TS 38.214
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Zero Power reference measurement value per beam (average value – dBm) – Intercell Interference Measurements | dBm | 1 .. 15 min. | [Dial20] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Para. 5.1.6 (ref.[5]) CSI signal-to-noise and interference ratio (CSI-SINR) histogram | Percent | 1 .. 15 min. | [Dial21] | Measurement definition in 3GPP TS 38.215
New measurement reporting | + +Table 6.2.1.2-2. Downlink MIMO quality dials + +| Interface | Source
→
Target | Description | Units | Control Period | Reference | New or existing config | +|-----------|-------------------------|--------------------------------------------------------------------------------------|--------------|----------------|-----------|------------------------| +| O1 | Non-RT RIC
→
O-DU | Minimum Downlink post-pairing SINR Threshold for MU-MIMO UEs (Operator set [0,..25]) | Integer (dB) | 1 .. 15 min. | [Knob02] | New | + +Table 6.2.1.2-3. Downlink MIMO power control knobs + +Note: It is FFS whether any of the listed measurements have any dependency on O-RU and if any information needs to be exchanged over O-RAN FH m-plane interface from O-RU to O-DU. + +##### O-RAN Entity roles: + +- 1) SMO & Non-RT RIC + - a) Collect existing configuration and performance data from RAN + - b) Trigger AI/ML Model training/update and deployment as necessary + - c) Apply power control recommendations from rApp via R1 and O1 interface using config management service. +- 2) O-CU + - a) Report current configuration and performance data to non-RT RIC rApp via O1 interface if requested by rApp. +- 3) O-DU + - a) Report current configuration and performance data to non-RT RIC rApp via O1 interface. + - b) Apply power control related knobs based on rAPP recommendation. + +#### 6.2.1.3 Impact Analysis on O-RAN WGs + +*Editor's note: This is an initial impact analysis as part of the WG1 UCTG work on mMIMO. The intention is to estimate the expected standardization effort within the O-RAN working groups. It is up to the WGs to decide how the mMIMO functionality should be specified in specifications of each WG, and whether it will be part of existing or new set of specifications.* + +##### WG1 (use cases, architecture) Impact + +- Update WG1 use case analysis report and use-case detailed specification with downlink power control use case. No impact to existing architecture. + +##### WG2 (Non-RT RIC, A1, R1) Impact + +- Assess impact to A1 and R1 interfaces and non-RT RIC architecture, including AI/ML training and deployment. +- Add new use cases and corresponding requirements and specifications in case impact to A1 or R1 interfaces. + +##### WG5 (O-CU and O-DU) Impact + +- Assess impact on O-CU and O-DU support for dials and knobs described in the use-case. + +##### WG10 (SMO, O1) Impact + +- Assess impact with PM coordination group and IM/DM coordination group on support of proposed dials (measurements) and knobs (configuration IM/DM) and incorporation in existing O1 interface models, as well as any required coordination with 3GPP + +Summary: A detailed analysis of the specification impact is to be completed. There is large specification impact to specify new proposed measurement definitions and measurement reporting in 3GPP or in O-RAN. The impact of the required measurements and configurations will be reduced if they are already part of ongoing/upcoming O-RAN specifications (ffs) or are being considered for specification in other bodies such as 3GPP (ffs). + +#### 6.2.1.4 Complexity/Gains + +The simulation of 8 UEs in an urban setting (without intercell interference just to keep it simple) is shown in Figure 6.2.1.4-1 as a first step in simulation as next steps cell clusters are planned to be simulated as well to confirm intercell interference performance. It was based on uniform downlink TX power distribution and a generic zero forcing precoding algorithm (Green dots). Clearly the resulting downlink SINR is fairly uniform for most of the UEs except for UE#6 and UE#8 which tend toward the cell edge. The poor SINR of these two UEs can be mitigated by either monitoring the separability and potentially deleting them from the pairing with the other 6 UEs or by reallocating some of the power to the other UEs. In the cases where there may be excessive SINR for a near-center of the cell UE (not in this simulated case) the downlink TX power can be reallocated to benefit the cell edge UEs to bring them up to a minimum SINR for example. Specifically, general statistical trends of poor cell edge SINR will be detected by the measurements (dials) and optimized by the AI/ML to result in an appropriate minimum SINR threshold. + +- Bandwidth = 20 MHz +- 8x8 Antenna Array +- 2 GHz frequency + - Urban High Rise +- Base station height = 20 meters +- UE height = all at ground level + +![Scatter plot titled 'SINR for UEs in Cell #1' showing SINR (dB) on the y-axis (ranging from -20 to 20) versus UE # in set on the x-axis (ranging from 1 to 8). The data points are: (1, 8), (2, 7), (3, 6), (4, 8), (5, 8), (6, -22), (7, 7), (8, -6).](77559e17b597785019c144cedf4b683f_img.jpg) + +| UE # in set | SINR (dB) | +|-------------|-----------| +| 1 | 8 | +| 2 | 7 | +| 3 | 6 | +| 4 | 8 | +| 5 | 8 | +| 6 | -22 | +| 7 | 7 | +| 8 | -6 | + +Scatter plot titled 'SINR for UEs in Cell #1' showing SINR (dB) on the y-axis (ranging from -20 to 20) versus UE # in set on the x-axis (ranging from 1 to 8). The data points are: (1, 8), (2, 7), (3, 6), (4, 8), (5, 8), (6, -22), (7, 7), (8, -6). + +**Figure 6.2.1.4-1. SINR distribution for UEs from simulation** + +Thus, the gain is highly dependent on the distribution of the SINR per UE but clearly TX power can be reallocated to improve poorly performing UEs. However, the objective in this case is not to increase the capacity but to insure good overall customer experience. + +The complexity of having histograms requires generally low complexity since it reduces the data rates across the O-RAN interfaces and keeps the high rate processing in the real-time capable processing hardware either in the DU or the RU with FPGA and CPU/GPU capabilities. + +Other downlink (and uplink) power/SINR optimization is described in references Bjornson [3] and Marzetta [4] that either adjust downlink power directly or optimize SINR targets specifically for cell edge users and show good performances for minimum user throughputs (directly proportional to minimum SINR) of up to 100% for the downlink and 50% for the uplink [4]. + +#### 6.2.1.5 Summary + +In summary, a difference in SINR as received by paired MU-MIMO UEs has been shown for a system without inter-cell interference. Further simulations at system level are under consideration. The gain of this use case in terms of cell edge and overall cell performance will depend on the actual L2 scheduler implementation and the consideration of this information by the L2 scheduler. A complexity analysis was not part of the pre-normative phase. + +### 6.2.2 Solution 2: MU-MIMO Pairing Enhancement (User Separability or Pairing Control) + +#### 6.2.2.1 Problem Statement, Solution, and Value Proposition + +Existing channel orthogonality between multiple users is a key criterion to create user separability and allow for the opportunity to share radio frequency resources simultaneously. Without so, residual interference will be too high to maintain adequate post pairing radio link signal quality levels required to sustain MU-MIMO mode assignments. With mobility there is an added demand to adjust beamforming weight assignments to not only maintain signal power levels at the user end (beam quality), but also to continuously limit the inter user interference experienced between users assigned with the same radio resource allocations. In the absence of creative solutions that capably and in a timely manner respond to the above-described challenges, the 5G massive MIMO deployment will fail to utilize the full capability of large antenna arrays powered by transceivers designed to transmit data channel signals towards a spatially confined direction. Schedulers will also fail to realize potential multiplexing gains as fewer radio resource blocks are shared between users within the same cell, reducing spectral efficiency. + +Important too is the need to efficiently identify users with low demand for radio resources - sources of bursty traffic. An intelligent assessment of how best such users can be effectively paired, if at all, with other users needs to be pre-determined by the radio intelligent controller. Channel estimation mechanisms that can be extrapolated in time and do not risk becoming stale so they can be utilized effectively to generate accurate weights and applied rapidly, is critical. For lower volume buffer data, an unacceptable gap in the above can create failure in MU-MIMO pairing. In summary, this use case suggests various measurement objects (aka dials) that are recommended as input into the AI/ML analytics Apps to optimally determine the outputs (aka knobs) required to optimize the MU-MIMO feature operation. The following section presents the input and output parameter and possible use in an AI/ML analytics App. + +##### Scheduled UEs + +1. Histogram of UEs with data in Buffer [Dial01] + - a. If greater than “Threshold\_High,” evaluate cell’s MU-MIMO pairing history and set status of cell as AI/ML optimization candidate. +2. # Of scheduled MU-MIMO UEs per TTI [Dial04] + - a. AI/ML shall aspire to improve or maintain pairing success rate + - b. Correlate to histogram of UEs with data in buffer +3. Include percent of UE pairs evaluated for orthogonality by the scheduler [Dial05] +4. AI/ML shall aspire to keep difference between 3. and “# Of scheduled MU-MIMO UEs per TTI” at a minimum by minimizing residual interference of paired UEs. +5. iBLER for MU-MIMO UEs [Dial06] + - a. AI/ML shall aspire to improve pre pair value vs post pair + - b. Delta iBLER should not exceed A dB, for a given pair size, for example. +6. TTI of Evaluation vs. TTI of Scheduled Pairing or the Offset [Dial08] + - a. For lower volume buffer data, an unacceptable gap in the above can create failure in MU-MIMO pairing + +##### UE Spatial Separability + +1. Paired UE Orthogonality Factor [Dial09] + - a. This is a measure of MU-MIMO performance sustainability. Spectral Efficiency will increase. It is an implicit reflection of residual interference among paired UEs. +2. Path Loss Delta [Dial10] + - a. If orthogonality factor is high, and pathloss delta is high, AI/ML should be used due to an inherent decorrelation of channel between the served UEs, for a given spatial distribution. + +##### Coherence Block + +1. Coherence Time [Dial11] + - a. AI/ML is used to evaluate channel estimation reliability, to fit beamforming and MU-MIMO pairing process cycle into the coherence time. +2. Coherence Bandwidth [Dial12] + - a. To maximize PRB/TTI assignment to MU-MIMO vs. SU-MIMO. + +##### Downlink MIMO Quality + +1. Downlink CQI Report Histogram [Dial18] + - a. To safely scale the MU-MIMO pairing size – CQI is expected to fall with increase in pairing size. According to the CQI and number of candidates that exist, AI/ML shall intelligently optimize pairing. +2. ZP Reference Measurement Value per Beam [Dial20] + - a. ZP CSI-RS is to be used for interference measurement (Indication of likely residual interference) + +##### Uplink MIMO Quality + +1. Minimum, Average and Maximum Uplink SINR or Co-UE interference, Noise and External Interference level per UE to allow assessments of Uplink channel pairing decisions similar to the downlink [Dial22] +2. Percent Time MU-MIMO UEs are at Maximum TX Power and $< 5$ PRB allows assessments of UL coverage [Dial24] + +##### Frequency Reuse Factor for Pilots + +1. Histogram of re-used Pilots (SRS) from neighbor cells [Dial25] + - a. Non-Real /Real Time RIC will work to assign different SRS to in-cell UEs to improve channel estimation performance + +##### Uplink Covariance + +1. Post Pilot Removal Uplink Covariance [Dial26] + - a. Measure of channel orthogonality between MU-MIMO UEs and selection optimization, through channel estimation + +##### Pilot and Coherence Block Joint Distribution [Dial27] + +1. Histogram of Selected Pilot Sequence Length and Histogram of Selected Coherence Block + - a. AI/ML will impart intelligence into the robustness of the pilot signals used for channel estimation + +##### Spectral Efficiency + +1. MU-MIMO PRB Utilization Histogram [Dial30] + - a. AI/ML will monitor to evaluate data Bytes transmitted, correlated to MU-MIMO pairing levels. This will be compared to BLER reports for pairing decisions. +2. Total PRB % Used Supporting MU-MIMO histogram [Dial31] + - a. As above +3. MU-MIMO PDCP Volume Histogram [Dial32] + - a. Required for spectral efficiency calculation +4. MU-MIMO Throughput DRB vs. MU-MIMO Layers [Dial33] + - a. Required to evaluate MU-MIMO pairing effectiveness and scalability +5. MU-MIMO Spectral Efficiency [Dial34] + - a. Required to evaluate MU-MIMO pairing effectiveness + +With the above inputs, the AI/ML app will calculate the outputs to control the optimization of the Massive MIMO system below. + +##### Uplink UE Transmit Power Control + +1. Minimum Uplink SINR Threshold for MU-MIMO UEs [Knob01] + - a. Useful to ensure SRS reciprocity-based beamforming approach is effective + +##### Downlink Transmit Power Allocation + +1. Minimum Downlink SINR Threshold for MU-MIMO UEs [Knob02] + - a. This can be a variable based on traffic loading within a cell. A lower threshold can be tolerated, but greater than a cut-off threshold that is already existing as an implicit indicator (pre pairing evaluation) prior to pairing. It can also be a variable based upon the pairing size (Number of UEs in MU-MIMO mode, within same paired group) + +##### Parallel Scheduling Control + +1. Uplink SINR Threshold [Knob03] +2. Downlink SINR Threshold [Knob04] +3. Minimum in-buffer PDU Count [Knob05] + - a. To minimize beamforming and MU-MIMO process overhead and scheduling delays +4. Minimum projected TTIs required for scheduling [Knob06] + - a. To minimize beamforming and MU-MIMO process overhead and scheduling delays +5. Threshold for pairing candidates' SRS strength [Knob07] + - a. To make MU-MIMO beamforming more effective, especially for Zero Forcing technique. +6. Maximum Number of Paired Candidates [Knob09 or Knob08] + - a. A means to limit Pairing size based on evaluation metrics and performance of larger pairing sizes +7. UE Pairing Selection Threshold Based on 5QI Threshold for Pairing [Knob10] + - a. Prioritizing pairing during congestion, based on 5QI QOS characteristics + +##### SRS Sequence and Distribution + +1. SRS Length [Knob10] +2. SRS Sequence Partition [Knob11] + +Both are required to optimize performance based upon channel estimation outcome, reflected in the orthogonality between paired users or their residual interference levels. + +##### Quiescent Antenna Weight Application + +1. Customizable set of Antenna Weights [Knob15] + - a. Optimization of array structure to improve spatial resolution of beams to support a wide distribution of MU-MIMO users. + +Realizing that significant increases in network capacity generally require large capital outlays to increase the available spectrum and to purchase new equipment, the promise of Massive MIMO to increase the capacity and essentially the available spectrum usage efficiency by adopting approaches relying upon advanced antenna arrays, is strongly considered. However, such approaches at the same time add additional interference among the users that are simultaneously using the + +same spectrum. In fact, in general, more simultaneous users add more interference to each individual user and thus a careful balance between capacity and quality must be maintained or unhappy users can ‘churn’ to competitors. + +The AI/ML assisted modeling and training output, along with the non-RT RIC based enhancement/inference, will strive to deliver end goal solution selections and system configuration options that upon adoption within the respective domains where they reside, realize an optimization framework that maximizes the potential of a MU-MIMO feature. Capacity augmentation will be realized by successfully assigning MU-MIMO layers to a greater number of users simultaneously, more often, and more uniformly across the serving area of each gNB. Dials that capture measurement values as appropriately defined in this document, and knobs which are configured to manage the operations of critical techniques that define the MU-MIMO feature and its underlying algorithms meant to enhance pairing capabilities, will provide the platforms for a successful implementation that realizes the following goals: + +- 1) Increased spectral efficiency through the support of higher total throughput, by a factor more closely proportional to the number of layers supported by the DU +- 2) Robust MU-MIMO layers with per link MCS that is closely reflective of power loss at transmitter, proportional to number of layers +- 3) More resource blocks assigned to MU-MIMO mode + +Particularly, AI/ML is used to optimize the network capacity utilizing a channel reciprocity-based approach vs. maintenance of the quality of the connection for each user with shared resources. Additionally presented is the approach that involves using a GoB-based solution, similar in objective to the reciprocity one, whereby balance between user quality and capacity realized, is aimed. + +The dials needed to assess user quality generally consist of measuring the quality (SINR, CQI, etc.) of both the Uplink and Downlink for each user. Other metrics include the Uplink power margin for the user and the user mobility among many other factors (see following sections for a comprehensive list of many of them). Other metrics that provide assessments of capacity include the normal cell volume and cell throughputs along with congestion (active connected users with data in the buffer). For Massive MIMO the individual “user separability” impacts the MU-MIMO pairing performance (and thus capacity) such that the users cannot be arbitrarily paired or else low user spatial separability can mutually degrade the user link quality due to significant inter-user interference. Thus, user separability must be tracked and used to train the AI/ML component in to optimize the capacity while constrained to insure minimum levels of user quality. The AI/ML component, after training, will output “knobs” to appropriately adjust the capacity to attempt to meet the user volume, throughput, and latency demands. Examples of the knobs for reciprocity are the allocations of Downlink Transmit Power allocation among users (see Section 6.2.1 above), the assignment of levels of pairing or parallelism, assignment of modes of Su-MIMO vs. Mu-MIMO (see Section 6.2.3 below for more details), etc. + +An alternative approach to the Reciprocity (mainly for TDD systems) based solution is the GoB approach, which relies upon using the downlink CSI-RS reference signal to estimate the downlink channel (CSI). Here, a quantized model of the CSI is fed back to the base station in order to make proper precoding decisions for the set of MU-MIMO users. This approach can make use of shadow fading CSI information (type I) that is estimated or even the combination of shadow and fast fading (type II) CSI information that is fed back with, of course, a larger required number of bits. + +The dials section enumerates a list of the user feedback CSI information that should be monitored to assess the state of the channel and the quality of the channel (CQI, SINR, etc.). In addition, the link quality can also be associated with the choice of multiple downlink beams that are received by the user and these need to be properly monitored as well. In addition, various “sub-beam” modalities must be monitored that give more information about the beam characteristics (e.g., beam phase, etc.). In this case, the user beams (vs. the user channels for reciprocity) need to be assessed for “user separability” as well. + +There are several methods that can be applied, after training in the ML/AI component, that can be used to ensure user quality while maximizing capacity. A “knobs” implementation that controls the beam shapes and power allocation (while assessing the user pairing degree) can be used to ensure user quality. + +#### 6.2.2.2 Architecture/Deployment Options + +The non-RT RIC trains and updates the specific MU-MIMO pairing enhancement AI/ML models. Figure 6.2.2.2-1 reflects the functional dependencies of the AI/ML implementation framework. The MU-MIMO Pairing Enhancement (MPE) rAPP performs optimization required to realize multiplexing gains through the sharing of PHY layer resource blocks between several end users who are in transmission while on the PDSCH. As shown Figure 6.2.2.2-1, the rApp uses O1 and FH m-plane measurement data (via SMO exposed services). The MU-MIMO Pairing Enhancement rApp running in the non-RT RIC uses O1/FH-m data to optimize cell MU-MIMO layer realization by configuring O-RU over FH m-plane or O-DU over O1 interface parameters (via SMO exposed services over R1 interface). + +![O-RAN Architecture Diagram for MIMO pairing use-case. The diagram shows a hierarchical architecture. At the top, a 'Non-RT RIC' box contains 'AI/ML training' and 'MPE rApp'. To its right is the 'SMO' box containing 'O1/FH services'. A dashed arrow labeled 'R1' points from the SMO to the MPE rApp. Below the Non-RT RIC is the 'Near-RT RIC' box, connected to the Non-RT RIC by a double-headed arrow labeled 'A1'. Below the Near-RT RIC is the 'O-DU' box, connected by a double-headed arrow labeled 'E2'. Below the O-DU is the 'O-RU' box, connected by a double-headed arrow labeled 'FH M-Plane'. A vertical line on the right side of the diagram represents the 'O1' interface. It has a downward arrow from the SMO labeled 'MIMO Config' and an upward arrow from the O-DU labeled 'Data Collection'.](93abff78fac32820fc24080a70737823_img.jpg) + +O-RAN Architecture Diagram for MIMO pairing use-case. The diagram shows a hierarchical architecture. At the top, a 'Non-RT RIC' box contains 'AI/ML training' and 'MPE rApp'. To its right is the 'SMO' box containing 'O1/FH services'. A dashed arrow labeled 'R1' points from the SMO to the MPE rApp. Below the Non-RT RIC is the 'Near-RT RIC' box, connected to the Non-RT RIC by a double-headed arrow labeled 'A1'. Below the Near-RT RIC is the 'O-DU' box, connected by a double-headed arrow labeled 'E2'. Below the O-DU is the 'O-RU' box, connected by a double-headed arrow labeled 'FH M-Plane'. A vertical line on the right side of the diagram represents the 'O1' interface. It has a downward arrow from the SMO labeled 'MIMO Config' and an upward arrow from the O-DU labeled 'Data Collection'. + +Figure 6.2.2.2-1. O-RAN Architecture Diagram for MIMO pairing use-case + +![Call Flow Diagram for MIMO pairing use-case. The diagram shows interactions between Service Management and Orchestration (SMO) and O-RAN components (Near-RT RIC, O-DU, O-RU). The SMO is divided into Collection & Control and Non-RT RIC. The O-RAN components are Near-RT RIC, O-DU, and O-RU. The flow includes MIMO configuration data collection (steps 1-5), MIMO performance data collection (steps 6-10), ML workflow (steps 11-12), and MIMO monitoring and optimization (steps 13-19).](64ecef7181dd25b626bf999b65a81d22_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management and Orchestration + participant SMO_C as Collection & Control + participant SMO_NRT as Non-RT RIC + participant O_RAN as O-RAN + participant O_RAN_NRT as Near-RT RIC + participant O_RAN_ODU as O-DU + participant O_RAN_ORU as O-RU + + Note over SMO: MIMO configuration data collection + SMO_NRT->>O_RAN_NRT: 1 <> Request MIMO configuration parameters + SMO_NRT->>O_RAN_ODU: 2 <> Request MIMO config + O_RAN_ORU-->>O_RAN_NRT: 3 <> Report MIMO config + O_RAN_NRT->>SMO_NRT: 4 <> Report MIMO config + O_RAN_NRT->>SMO_NRT: 5 <> Report MIMO configuration parameters + + Note over SMO: MIMO performance data Collection + SMO_NRT->>O_RAN_NRT: 6 <> Request MIMO performance data collection + SMO_NRT->>O_RAN_ODU: 7 <> MIMO performance measurement configuration + O_RAN_ORU-->>O_RAN_NRT: 8 <> MIMO data collection + O_RAN_NRT->>SMO_NRT: 9 <> MIMO data collection + SMO_NRT->>O_RAN_NRT: 10 <> Retrieval of collected data + + Note over SMO: ML workflow + SMO_NRT->>O_RAN_NRT: 11 Training of ML models + SMO_NRT->>O_RAN_NRT: 12 Deploy ML models + + Note over SMO: MIMO monitoring and optimization + O_RAN_ORU-->>O_RAN_NRT: 13 <> Data collection for inference and optimization + SMO_NRT->>O_RAN_NRT: 14 <> Data collection for inference and optimization + SMO_NRT->>O_RAN_NRT: 15 <> Data retrieval of RAN + SMO_NRT->>O_RAN_NRT: 16 Performance monitoring & evaluation + SMO_NRT->>O_RAN_NRT: 17 <> updated MIMO configuration + SMO_NRT->>O_RAN_ODU: 18 <> Apply MIMO configuration + O_RAN_ORU-->>O_RAN_NRT: 19 <> Apply MIMO configuration + +``` + +Call Flow Diagram for MIMO pairing use-case. The diagram shows interactions between Service Management and Orchestration (SMO) and O-RAN components (Near-RT RIC, O-DU, O-RU). The SMO is divided into Collection & Control and Non-RT RIC. The O-RAN components are Near-RT RIC, O-DU, and O-RU. The flow includes MIMO configuration data collection (steps 1-5), MIMO performance data collection (steps 6-10), ML workflow (steps 11-12), and MIMO monitoring and optimization (steps 13-19). + +Figure 6.2.2.2-2. Call Flow Diagram for MIMO pairing use-case + +In the call in Figure 6.2.2.2-2, the rApp can request the current MIMO configuration listed in Table 6.2.2.2-12 (steps 2-5), as well as current network measurements and KPIs listed in Table 6.2.2.2-1 to Table 6.2.2.2-11 (steps 7-10). The R1 interface is used by the rApp to communicate these requests to SMO, which in turn coordinates the collection via O1 interface. The AI/ML model that is part of the rApp will use the measurements to evaluate the current capacity and UE performance and if required, will generate a recommendation to update one or more of the identified configuration knobs (step 16). This new recommendation is sent to SMO via R1 interface, and finally communicated to the O-DU via O1 interface (step 18). + +##### Requirements + +In order to achieve the value proposition described above, the key Massive MIMO KPIs or dials need to be monitored to assess the state of the system. A proposed set is discussed in the following sections. + +All the dials/measurements listed here are required at a configurable granularity in multiples of 1 minute, ranging from 1 to 15 minutes. + +| Interface | Source
→
Target | Description | Units | Measurement Period | Reference | New or existing measurement/reporting specification | +|-----------|-------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------------|-----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Histogram of UEs with data in the buffer. If greater than “Threshold_High,” evaluate cell’s MU-MIMO pairing history and set status of cell as AI/ML optimization candidate. | Percent | 1 .. 15 min. | [Dial01] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Angle of Arrival or Beam ID histogram. Only for GoB Feedback. | integer | 1 .. 15 min. | [Dial03] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | # of scheduled MU-MIMO UEs per TTI (histogram of % UE=1, % UE=2 ,% UE = max limit (K)) | percent | 1 .. 15 min. | [Dial04] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Percent of UE pairs evaluated for orthogonality by the scheduler (histogram, %=0, %=1, %=2, ....%=P) | percent | 1 .. 15 min. | [Dial05] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | iBLER (initial Block Error Rate, BLER) for the MU-MIMO UEs | percent | 1 .. 15 min. | [Dial06] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | UEs scheduled for Mu-MIMO pairing (histogram, %UE=0, %UE=1, ..., percent UE = K) | percent | 1 .. 15 min. | [Dial07] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | TTI of Evaluation vs. TTI of Scheduled pairing or the offset (histogram %TTI=1, %TTI=2,..., %TTI = 100) | Count | 1 .. 15 min. | [Dial08] | New measurement definition
New measurement reporting | + +Table 6.2.2.2-1. Scheduled UE dials + +| | | | | | | | +|----|-------------------------|---------------------------------------------------------------------------------------------------------------------------------------|-----------------------------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Paired UE Orthogonality Factor (min UE pair Cross Correlation Coefficient [0,1] for each K number of parallel UEs ) histogram | dB (0,...,-50) for K values | 1 .. 15 min. | [Dial09] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Path Loss Delta distribution across all Mu-MIMO UEs (percent vs. < 1 dB, < 3 dB, < 5 dB, < 10 dB, < 15 dB, < 20 dB, < 30 dB, > 30 dB) | Percent | 1 .. 15 min. | [Dial10] | New measurement definition
New measurement reporting | + +**Table 6.2.2.2-2. UE spatial separability dials** + +| | | | | | | | +|----|-------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Coherence Time averaged over all paired UEs (histogram of percent times < 1ms, < 10 ms, < 50 ms, < 100 ms, <500 ms) | Percent | 1 .. 15 min. | [Dial11] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Coherence Bandwidth averaged over all paired UEs (histogram of percent of BWs < 200 kHz, < 1 MHz, < 5 MHz, < 10 MHz, < 50 MHz, < 100 MHz) | Percent | 1 .. 15 min. | [Dial12] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Average of paired UE Coherence Block = Coherence Time * Coherence Bandwidth (histogram percent < 100, < 500, < 1000, <5000, < 10,000, > 10,000) | Percent | 1 .. 15 min. | [Dial13] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Histogram of SRS periods commanded (percent <2.5 ms, <5 ms, <10 ms, <20 ms, <40 ms, <100 ms, < 200 ms, < 400 ms) | Percent | 1 .. 15 min. | [Dial14] | New measurement definition
New measurement reporting | + +**Table 6.2.2.2-3. Coherence block dials** + +| | | | | | | | +|----|-------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Downlink CQI Report histogram (one CQI histogram (percent use vs. CQI index) for each number of Mu-MIMO UEs in parallel (e.g., 1,2,3,..K). See section 0 (GoB) for other use cases. | Percent | 1 .. 15 min. | [Dial18] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | ZP reference measurement value per beam (average value – dBm) | dBm | 1 .. 15 min. | [Dial20] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Para. 5.1.6 (ref.[5]) CSI signal-to-noise and interference ratio (CSI-SINR) histogram | Percent | 1 .. 15 min. | [Dial21] | New measurement definition
New measurement reporting | + +**Table 6.2.2.2-4. Downlink MIMO quality dials** + +| | | | | | | | +|----|-------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Minimum, Average (linear), and Maximum Uplink SINR or Co-UE interference, Noise and External Interference Level per UE (Mu-MIMO pair histogram (SINR range: -10 dB to + 30 dB) for 1,2, 3, ..., K UEs) | Percent | 1 .. 15 min. | [Dial22] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Percent time Mu-MIMO UEs are at maximum TX power and < 5 PRB | Percent | 1 .. 15 min. | [Dial24] | New measurement definition
New measurement reporting | + +**Table 6.2.2.2-5. Uplink MIMO quality dials** + +| | | | | | | | +|----|-------------------------|----------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Histogram of re-used pilots (CSI-RS and SRS) from neighbor cells (reused pilots = 0, 1, 2, ..., M) | percent | 1 .. 15 min. | [Dial25] | New measurement definition
New measurement reporting | +|----|-------------------------|----------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| + +**Table 6.2.2.2-6. Frequency Reuse factor for Pilots dials** + +| | | | | | | | +|----|-------------------------|----------------------------------------------------------------------------------------------------------------------------------|-------------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Post Pilot Removal Uplink Covariance (10 sec. average) per MU-MIMO UE vs. Pairing size 1,...,K (Section 3.3 for other use cases) | Fixed point | 1 .. 15 min. | [Dial26] | New measurement definition
New measurement reporting | +|----|-------------------------|----------------------------------------------------------------------------------------------------------------------------------|-------------|--------------|----------|---------------------------------------------------------| + +**Table 6.2.2.2-7. Uplink covariance dials** + +| | | | | | | | +|----|-------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Histogram of Selected Pilot Sequence length (<12, <24, <48, <96, <192, <384, etc.) and histogram of Selected Coherence Block (< 100, < 500, < 1000, < 5000, < 10,000, < 100,000, > 100,000 symbols) joint histogram | percent | 1 .. 15 min. | [Dial27] | New measurement definition
New measurement reporting | +|----|-------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| + +**Table 6.2.2.2-8. Pilot and Coherence Block Joint Distribution dials** + +| | | | | | | | +|----|-------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | MU-MIMO PRB Utilization Histogram | Percent | 1 .. 15 min. | [Dial30] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Total PRB % Used Supporting MU-MIMO histogram | Percent | 1 .. 15 min. | [Dial31] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | MU-MIMO PDCP Volume histogram | Percent | 1 .. 15 min. | [Dial32] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | MU-MIMO DRB (DL and UL) Throughput Histograms (min., ave., and max.) (100 kbps, 200, kbps, etc. 10 Gbps) vs. MU-MIMO layers (1,2,...,K) | Percent | 1 .. 15 min. | [Dial33] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | MU-MIMO Spectral Efficiency (8*PDCP Volume/(BW*PRB utilization), bits/sec./Hz histogram over measurement period, where BW = bandwidth, Hz). Note: All parallel/paired PRBs count as one over a TTI | Percent | 1 .. 15 min. | [Dial34] | New measurement definition
New measurement reporting | + +**Table 6.2.2.2-9. Spectral Efficiency dials** + +| | | | | | | | +|----|-------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|-----------------------------------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | SSB Wide-beam (by Beam index) selected during data transmission (histogram of percent usage vs. beam index (e.g., 0-7 for 3-6 GHz)) | Percent | 1 .. 15 min. | [Dial39] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | CRI-RSRP per Port (RSRP histogram from -130 to -70 dBm histogram in 2 dB steps | Percent | 1 .. 15 min.
0.5 - 1 sec for Near-RT | [Dial40] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | PMI index histogram for Type II feedback (percent usage per PMI index) | Percent | 1 .. 15 min. | [Dial41] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Type 2 Port Selection Codebook 2 nd stage PMI reporting – Wideband Amplitude co-efficient histogram used most (1, ½, ¼, 1/8, 1/16, 1/32, 1/64, 0) per beam | Percent | 1 .. 15 min.
0.5 - 1 sec for Near-RT | [Dial42] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Type 2 Port Selection Codebook 2 nd stage PMI reporting – Wideband Amplitude co-efficient histogram used least (1, ½, ¼, 1/8, 1/16, 1/32, 1/64, 0) per beam | Percent | 1 .. 15 min.
0.5 - 1 sec for Near-RT | [Dial43] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Type 2 Port Selection Codebook 2 nd stage PMI reporting – Sub-band co-phasing “phase shifts” maximum shift per beam histogram | Percent | 1 .. 15 min.
0.5 - 1 sec for Near-RT | [Dial44] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Type 2 Port Selection Codebook 2 nd stage PMI reporting – Sub-band co-phasing “phase shifts” minimum shift per beam histogram | Percent | 1 .. 15 min.
0.5 - 1 sec for Near-RT | [Dial45] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Type 2 Port Selection Codebook 2 nd stage PMI reporting – Sub-band co-phasing “phase shifts” most used quantized value per beam histogram | Percent | 1 .. 15 min.
0.5 - 1 sec for Near-RT | [Dial46] | New measurement definition
New measurement reporting | + +Table 6.2.2-10. Beam Management Monitor dials + +| | | | | | | | +|----|-------------------------|-----------------------------------------------------------------|--------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Maximum Eigenvalue distribution of the uplink covariance matrix | Number | 1 .. 15 min. | [Dial47] | New measurement definition
New measurement reporting | +|----|-------------------------|-----------------------------------------------------------------|--------|--------------|----------|---------------------------------------------------------| + +**Table 6.2.2.2-11. TDD Channel Estimation dials** + +| | | | | | | | +|----|-------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT RIC | Total number of MU-MIMO paired users, counting by PRBs where pairing happened, across all TTIs during collection interval | Number | 1 .. 15 min. | [Dial48] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Total number of PRBs supporting MU-MIMO mode, across all TTIs during collection interval | Number | 1 .. 15 min. | [Dial49] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Avg. number of MU-MIMO layers assigned per TTI per PRB (PRBs with pairing) | Number | 1 .. 15 min. | [Dial50] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Histogram of Number of UEs in MU-MIMO mode (2,3,4...N) vs Avg. Number of MU-MIMO layers supported. Information derived per PRB where multiplexing is occurring, per TTI, over collection interval | Number | 1 .. 15 min. | [Dial51] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT RIC | Histogram of DL MCS for MU-MIMO usage (percentage for MCS = 1, 2, ....., max.) | % | 1 .. 15 min. | [Dial52] | New measurement definition
New measurement reporting | + +**Table 6.2.2.2-12. Links and layers dials** + +Similar to the measurement and monitoring objective of the “dials” section, the control of key parameters is the objective of the “knobs” section. This allows the value proposition of allowing each operator to satisfy their respective unique optimality criteria via emerging AI/ML technologies. + +| | | | | | | | +|----|-------------------|------------------------------------------------------------------------------------------------------------------------------------------|------------------|--------------|----------|---------------------------------------------------------| +| O1 | Non-RT RIC → O-DU | Uplink SINR threshold (for MU-MIMO eligibility) | Integer (dB) | 1 .. 15 min. | [Knob03] | New measurement definition
New measurement reporting | +| O1 | Non-RT RIC → O-DU | Downlink SINR threshold (for MU-MIMO eligibility) | Integer (dB) | 1 .. 15 min. | [Knob04] | New measurement definition
New measurement reporting | +| O1 | Non-RT RIC → O-DU | Minimum in-buffer PDU count (or traffic volume in Bytes) (buffer vol. selection requirement for scheduling, units = kbytes, FA = minute) | Integer (kbytes) | 1 .. 15 min. | [Knob05] | New measurement definition
New measurement reporting | +| O1 | Non-RT RIC → O-DU | Minimum projected TTIs required for scheduling (equivalent buffer TTIs required for scheduling, units = # TTI, FA = minute) | Integer, # TTI | 1 min. | [Knob06] | New measurement definition
New measurement reporting | +| O1 | Non-RT RIC → O-DU | Threshold for pairing candidates' SRS strength (units = dB relative to standard, standard is settable in dBm) | Integer, dBm | 1 .. 15 min. | [Knob07] | New measurement definition
New measurement reporting | +| O1 | Non-RT RIC → O-DU | Average number of paired candidates (units = 1,2,...,L) | Integer | 1 .. 15 min. | [Knob08] | New measurement definition
New measurement reporting | +| O1 | Non-RT RIC → O-DU | Maximum number of paired candidates (units = 1,2,...,L) | Integer | 1 .. 15 min. | [Knob09] | New measurement definition
New measurement reporting | +| O1 | Non-RT RIC → O-DU | UE pairing selection threshold based on 5QI threshold for pairing (units = 1,...,Q) | integer | 1 .. 15 min. | [Knob10] | New measurement definition
New measurement reporting | +| O1 | Non-RT RIC → O-DU | Quiescent Antenna Weight Application | Vector | 1 .. 15 min | [Knob21] | New measurement definition
New measurement reporting | +| O1 | Non-RT | Settable Number of SSB Beams / CSI-RS Resources | Integer | 1 .. 15 min | [Knob22] | New measurement definition | + +| | | | | | | | +|----|-----------------------------|----------------------------------------------------------------------------|-------------|----------------|----------|---------------------------------------------------------------------| +| | RIC →
O-DU | | | | | New
measurement
reporting | +| O1 | Non-
RT
RIC →
O-DU | Number of Refined/Narrow Beams
per SSB | Integer | 1 .. 15
min | [Knob23] | New
measurement
definition
New
measurement
reporting | +| O1 | Non-
RT
RIC →
O-DU | Settable Reference CSI-RS vs
Neighbor CSI-RS mapping for SSB
symbols | List
Set | 1 .. 15
min | [Knob24] | New
measurement
definition
New
measurement
reporting | +| O1 | Non-
RT
RIC →
O-DU | CSI-RS Density | Value | 1 .. 15
min | [Knob25] | New
measurement
definition
New
measurement
reporting | +| O1 | Non-
RT
RIC →
O-DU | Minimum Downlink SINR
Threshold for MU-MIMO UEs | Value | 1 .. 15
min | [Knob26] | New
measurement
definition
New
measurement
reporting | +| O1 | Non-
RT
RIC →
O-DU | SRS Length | Number | 1 .. 15
min | [Knob27] | New
measurement
definition
New
measurement
reporting | +| O1 | Non-
RT
RIC →
O-DU | SRS Sequence Partition | Group
ID | 1 .. 15
min | [Knob28] | New
measurement
definition
New
measurement
reporting | + +**Table 6.2.2.2-13. Output knobs (control) from MIMO pairing use-case** + +Note: It is FFS whether any of the listed measurements have any dependency on O-RU and if any information needs to be exchanged over O-RAN FH m-plane interface from O-RU to O-DU. + +##### O-RAN Entity roles: + +- 1) SMO & Non-RT RIC + - a) Collect existing configuration and performance data from RAN + - b) Trigger AI/ML Model training/update and deployment as necessary + - c) Apply MIMO pairing control recommendations from rApp via R1 and O1 interface using config management service. +- 2) O-CU nodes + - a) Report current configuration and performance data to non-RT RIC rApp via O1 interface if requested. +- 3) O-DU nodes + +- a) Report current configuration and performance data to non-RT RIC rApp via O1 interface. +- b) Apply MIMO pairing control related knobs based on rAPP recommendation. + +#### 6.2.2.3 Impact Analysis on O-RAN WGs + +*Editor's note: This is an initial impact analysis as part of the WG1 UCTG work on mMIMO. The intention is to estimate the expected standardization effort within the O-RAN working groups. It is up to the WGs to decide how the mMIMO functionality should be specified in specifications of each WG, and whether it will be part of existing or new set of specifications.* + +##### WG1 (use cases, architecture) Impact + +- Update WG1 use case analysis report and use-case detailed specification with MU-MIMO pairing control use case. No impact to existing architecture. + +##### WG2 (Non-RT RIC, A1, R1) Impact + +- Assess impact to A1 and R1 interfaces and non-RT RIC architecture, including AI/ML training and deployment. +- Add new use cases and corresponding requirements and specifications in case there is an impact to A1 or R1 interfaces. + +##### WG5 (O-CU and O-DU) Impact + +- Assess impact on O-CU and O-DU support for dials and knobs described in the use-case. + +##### WG10 (SMO, O1) Impact + +- Assess impact with PM coordination group and IM/DM coordination group on support of proposed dials (measurements) and knobs (configuration IM/DM) and incorporation in existing O1 interface models, as well as any required coordination with 3GPP. + +Summary: A detailed analysis of the specification impact is to be completed. There is large specification impact to specify new proposed measurement definitions and measurement reporting in 3GPP or in O-RAN. The impact of the required measurements and configurations will be reduced if they are already part of ongoing/upcoming O-RAN specifications (ffs) or are being considered for specification in other bodies such as 3GPP (ffs). + +### 6.2.3 Solution 3: MIMO mode selection (Mu-MIMO vs Su-MIMO selection optimization) + +In this section the use case pertaining to optimal selection of Su-MIMO vs. Mu-MIMO is addressed. We shall explicitly refer to various inputs (aka dials) that are recommended for input into the AI/ML analytics Apps in order to optimally determine the outputs (aka knobs) of the Mu-MIMO and Su-MIMO selection control. + +#### 6.2.3.1 Problem Statement, Solution, and Value Proposition + +A successful MU-MIMO operation involves the realization of as many orthogonal radio frequency channel links between multiple spatially separated users as possibly as supported by the implementation software at the digital domain. Key to + +such realization is the successful beamforming weight determination that enables not only the phase addition of multipath signals at the user receiver, but also the choice of precoding algorithms which limit the residual interference between the paired users. AI/ML driven solutions can optimize such selections, as captured also in Section 3.3. It can make sense for the scheduler to prioritize the assignment of radio resources to a MU-MIMO mode of operation during periods of congestion or when high latency requiring applications are supported (to free up other resources that can be assigned sooner). However, doing so at the expense of undesirably lower spectral efficiency on these assigned radio resources will reduce overall sector throughput levels and create poor user experience. It is important to find a means through the AI/ML agent to distinguish users and identify sectors where optimal operation means a greater assignment of SU-MIMO modes independently to users, especially those requiring higher throughput, using devices that are capable of supporting higher layer SU-MIMO count, and operating in an environment that sustains a greater channel rank. + +In this section, the use case pertaining to the optimal selection of SU-MIMO vs. MU-MIMO for assignment to users to maximize the realized spectrum efficiency is addressed. We shall explicitly refer to various inputs (aka dials) that are recommended for input into the AI/ML analytics Apps in order to optimally determine the outputs (aka knobs) for the MU-MIMO and SU-MIMO mode selection control. + +##### Indication of MIMO Type and Layers + +1. Percent TTIs SU-MIMO vs. MU-MIMO vs Hybrid (TTI with SU-MIMO and MU-MIMO) [Dial15] + - a. AI/ML training will use this data to further optimize scheduler with the aim to increase overall cell spectral efficiency, based on pairing opportunities, data in buffer, larger SU-MIMO layer assignments etc. +2. Joint Histogram of simultaneous MU-MIMO and SU-MIMO Layers assigned per PRB [Dial17] + - a. This joint histogram allows the operator to assess the Mu-MIMO layer performance and also the Su-MIMO performance conditioned on the Mu-MIMO layer example shown below: + +| Mu-MIMO/Su-MIMO | Su-MIMO Layer = 1 | Su-MIMO Layer = 2 | ... | Su-MIMO Layer = M | +|-------------------|-------------------|-------------------|-----|-------------------| +| Mu-MIMO Layer = 1 | 10% | 20% | ... | 20% | +| Mu-MIMO Layer = 2 | % | % | ... | % | +| ... | ... | ... | ... | ... | +| Mu-MIMO Layer = N | % | % | ... | % | + +**Table 6.2.3.1-1.** + +Optimization based upon AI/ML training might result in a joint histogram output reflecting a cell's operation that has now moved more to the lower right side of Table 6.2.3.1-1, relative to the pre optimization scenario belonging some place to the left upper part of Table 6.2.3.1-1. AI/ML exercise might identify for various loading conditions and end user device counts, how much optimization is possible to move performance from current position to one of a higher level, in accordance with the dimensions of Table 6.2.3.1-1. + +##### Downlink MIMO Quality + +1. Downlink CQI Report histogram (SU-MIMO) vs. chosen MCS/CQI index [Dial18] + - a. Histogram indicating higher CQI bias would mean that there is scope for scheduler to favor higher layer SU-MIMO assignment vs. MU-MIMO. Channel specific to cell, UE distribution favor and traffic loading is used for AI/ML training with this CQI report. +2. CSI signal-to-noise and interference ratio (CSI-SINR) histogram [Dial21] + - a. This metric gives an implicit indication of channel estimation reliability used for AI/ML training for GoB based MU-MIMO, using Type II feedback. If below a threshold, SU-MIMO can be prioritized + +over MU-MIMO. CSI-SINR can be used for mobility cases by imparting intelligence into the channel estimation confidence determination. + +##### Uplink MIMO Quality + +1. Minimum, Average (linear), and Maximum Uplink SINR per UE histogram (SINR range: -10 to +30 dB) (SU-MIMO) [Dial23] is required to check uplink quality for SU-MIMO vs. MU-MIMO selection. + +##### Condition Number + +1. SU-MIMO Condition number in dB histogram (21 dB to 0 dB) [Dial28] + - a. High Condition numbers reported at high percentage of times will discourage the AI/ML training to recommend SU-MIMO assignment +2. SU-MIMO Reported Rank distribution histogram (Rank = 1, ..., Max Rank) [Dial29] + - a. Used to estimate the feasibility of higher layer support + +Spectral Efficiency is constantly monitored to allow optimization using the following KPIs: + +1. MU-MIMO vs. SU-MIMO PRB Utilization Histogram [Dial30] and [Dial35] +2. MU-MIMO vs. SU-MIMO PDCP Volume histogram [Dial32] and [Dial36] +3. MU-MIMO vs. SU-MIMO DRB (DL and UL) Throughput Histograms [Dial33] and [Dial37] +4. MU-MIMO vs. SU-MIMO Spectral Efficiency [Dial34] and [Dial38] + +The following will be the outputs or knobs for the optimization App: + +##### MIMO Mode Setting + +1. Operator shall be able to set any UE to either SU-MIMO only or MU-MIMO only by QCI threshold [Knob13] + - a. A shutout mechanism for UEs under adversarial conditions for either of the two MIMO modes, as appropriately decided based upon AI/ML training output and inference. +2. Set SU-MIMO Rank – The Condition Number target [Knob14] + - a. If above an AI/ML (training outcome) determined threshold, and for UE buffer status, cell loading etc. MU-MIMO if viable, will be prioritized over SU-MIMO. + +##### Beam Commands + +1. CSI-RS Density [Knob20] + - a. Can be increased or decreased based on CSI feedback reliability as assessed and set as a target by AI/ML non-real time RIC. + +The reader is referred to Section 3.3 for an invaluable use case for selecting the Massive MIMO mode in each user environment. This use case can be expected to make feasible the ability to put priority upon MU-MIMO selection as a means towards achieving optimisation. However here we limit the scope to giving additional examples of how the subsequent list of dials and knobs can be exploited in various important use cases. + +With increased loading Massive MIMO systems will incur rising levels of interference on the uplink from connected users and on the downlink from the gNB. In addition to normal SINR measurements, the diagnosis of interference from all spatial directions uniformly (white spatial noise) versus specific directions (spatially correlated noise) will be of interest and will require MIMO modes (SU-MIMO vs MU-MIMO) to be properly selected for assignment on a user basis. Such implementation will optimize the per user and per cell throughputs, taking into consideration channel orthogonality conditions rank realizable, and per user effective bandwidth requirement. Optimization will also factor into consideration the interaction and dependencies between multiple features or capabilities, such as carrier aggregation vs. beamforming capability and carrier aggregation vs. MU-MIMO assignments, for example. + +Dials that indicate the type of spatial interference are included in the Uplink Covariance “dial” which is also required in the GoB handover use case in Section 3.3. Interference that could include inter-cell Pilot contamination must be + +identified and mitigated. Mitigation can be improved with pilot sequence tracking and distribution, as presented in the in the knobs section. + +#### 6.2.3.2 Architecture/deployment Options + +The non-RT RIC trains and updates the specific MIMO Mode Selection AI/ML models. Figure 6.2.3.2-1 reflects the functional dependencies of the AI/ML implementation framework. The MIMO Mode Selection (MMS) rAPP targets to optimize user throughput vs cell throughput. As shown in Figure 6.2.3.2-1, the rApp uses O1 and FH m-plane measurement data (via SMO exposed services). The MMS rApp running in the non-RT RIC uses O1 data to optimize cell MU-MIMO vs. SU-MIMO assignment by configuring O-DU over O1 interface parameters (via SMO exposed services over R1 interface). + +![O-RAN Architecture Diagram for MIMO mode selection use case](cb1c8b756a17151f5e2c60cf85a6a153_img.jpg) + +``` + +graph TD + subgraph SMO [SMO] + subgraph Non-RT_RIC [Non-RT RIC] + AI_ML_training[AI/ML training] + MMS_rApp[MMS rApp] + end + O1_FH_services[O1/FH services] + end + MMS_rApp <-->|R1| O1_FH_services + Non-RT_RIC <-->|A1| Near-RT_RIC[Near-RT RIC] + Near-RT_RIC <-->|E2| O_DU[O-DU] + O_DU <-->|FH M-Plane| O_RU[O-RU] + O1_FH_services -->|O1| Data_Collection[Data Collection] + Data_Collection --> O_DU + Data_Collection --> Near-RT_RIC + +``` + +The diagram illustrates the O-RAN architecture for MIMO mode selection. It shows a hierarchy of components: Non-RT RIC (containing AI/ML training and MMS rApp), SMO (containing O1/FH services), Near-RT RIC, O-DU, and O-RU. The MMS rApp in the Non-RT RIC is connected to the O1/FH services in the SMO via the R1 interface. The Non-RT RIC is connected to the Near-RT RIC via the A1 interface. The Near-RT RIC is connected to the O-DU via the E2 interface. The O-DU is connected to the O-RU via the FH M-Plane. The O1/FH services in the SMO are connected to the O-DU via the O1 interface, and the O-DU is connected to the Near-RT RIC via the Data Collection interface. + +O-RAN Architecture Diagram for MIMO mode selection use case + +Figure 6.2.3.2-1. O-RAN Architecture Diagram for MIMO mode selection use case + +![Call Flow Diagram for MIMO mode selection use case. The diagram shows interactions between Service Management and Orchestration (SMO) and O-RAN components (Near-RT RIC, O-DU, O-RU). The SMO is divided into Collection & Control and Non-RT RIC. The O-RAN components are Near-RT RIC, O-DU, and O-RU. The flow includes MIMO configuration data collection, MIMO performance data collection, ML workflow, and MIMO monitoring and optimization.](64ecef7181dd25b626bf999b65a81d22_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management and Orchestration + participant SMO_C as Collection & Control + participant SMO_NRT as Non-RT RIC + participant O_RAN as O-RAN + participant O_RAN_NRT as Near-RT RIC + participant O_RAN_ODU as O-DU + participant O_RAN_ORU as O-RU + + Note over SMO: MIMO configuration data collection + SMO_NRT->>SMO_C: 1 <> Request MIMO configuration parameters + SMO_C->>O_RAN_ODU: 2 <> Request MIMO config + O_RAN_ORU-->>O_RAN_NRT: 3 <> Report MIMO config + O_RAN_NRT->>SMO_C: 4 <> Report MIMO config + SMO_C->>SMO_NRT: 5 <> Report MIMO configuration parameters + + Note over SMO: MIMO performance data Collection + SMO_NRT->>SMO_C: 6 <> Request MIMO performance data collection + SMO_C->>O_RAN_ODU: 7 <> MIMO performance measurement configuration + O_RAN_ORU-->>O_RAN_NRT: 8 <> MIMO data collection + O_RAN_NRT->>SMO_C: 9 <> MIMO data collection + SMO_C->>SMO_NRT: 10 <> Retrieval of collected data + + Note over SMO: ML workflow + SMO_NRT->>SMO_C: 11 Training of ML models + SMO_C->>SMO_NRT: 12 Deploy ML models + + Note over SMO: MIMO monitoring and optimization + O_RAN_ORU-->>O_RAN_NRT: 13 <> Data collection for inference and optimization + O_RAN_NRT->>SMO_C: 14 <> Data collection for inference and optimization + SMO_C->>SMO_NRT: 15 <> Data retrieval of RAN + SMO_NRT->>SMO_C: 16 Performance monitoring & evaluation + SMO_C->>SMO_NRT: 17 <> updated MIMO configuration + SMO_NRT->>O_RAN_ODU: 18 <> Apply MIMO configuration + O_RAN_ORU-->>O_RAN_NRT: 19 <> Apply MIMO configuration + +``` + +Call Flow Diagram for MIMO mode selection use case. The diagram shows interactions between Service Management and Orchestration (SMO) and O-RAN components (Near-RT RIC, O-DU, O-RU). The SMO is divided into Collection & Control and Non-RT RIC. The O-RAN components are Near-RT RIC, O-DU, and O-RU. The flow includes MIMO configuration data collection, MIMO performance data collection, ML workflow, and MIMO monitoring and optimization. + +Figure 6.2.3.2-2. Call Flow Diagram for MIMO mode selection use case + +In the call in Figure 6.2.3.2-2, the rApp can request the current MIMO configuration listed in Table 6.2.3.2-6 (steps 2-5), as well as current network measurements and KPIs listed in Table 6.2.3.2-1 to Table 6.2.3.2-5 (steps 7-10). The R1 interface is used by the rApp to communicate these requests to SMO, which in turn coordinates the collection via O1 interface. The AI/ML model that is part of the rApp will use the measurements to evaluate the current capacity and UE performance and if required, will generate a recommendation to update one or more of the identified configuration knobs (step 16). This new recommendation is sent to SMO via R1 interface, and finally communicated to the O-DU via O1 interface (step 18). + +##### Requirements + +In order to achieve the value proposition described above, the key Massive MIMO KPIs or dials need to be monitored to assess the state of the system. + +All the dials/measurements listed here are required at a configurable granularity in multiples of 1 minute, ranging from 1 to 15 minutes. + +| | | | | | | | +|----|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT
RIC | Percent TTIs SU-MIMO vs. MU-MIMO vs Hybrid (TTi with SU-MIMO and MU-MIMO) | Percent | 1 .. 15 min. | [Dial15] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | Histogram of percent usage vs. # of MU-MIMO users (users = 2,...,K) | Percent | 1 .. 15 min. | [Dial16] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | Joint Histogram of simultaneous MU-MIMO and SU-MIMO Layers assigned per PRB (MU-MIMO percentage vs. MU-MIMO (layers 1,...,N) and N SU-MIMO (layers 1,...,M) histograms each conditioned on a given no. of MU-MIMO layers) | Percent | 1 .. 15 min. | [Dial17] | New measurement definition
New measurement reporting | + +**Table 6.2.3.2-1. Dials for indication of MIMO types and layers** + +| | | | | | | | +|----|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT
RIC | Downlink CQI Report histogram (one CQI histogram (percent use vs. CQI index) for each number of MU-MIMO UEs in parallel (e.g., 1,2,3,...K) (see Section 3.3 for other use cases) | Percent | 1 .. 15 min. | [Dial18] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | ZP reference measurement value per beam (average value – dBm) | dBm | 1 .. 15 min. | [Dial20] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | Para. 5.1.6 ([5]) CSI signal-to-noise and interference ratio (CSI-SINR) histogram | Percent | 1 .. 15 min. | [Dial21] | Existing specification [5]
New measurement reporting | + +**Table 6.2.3.2-2. Dials for downlink MIMO quality** + +| | | | | | | | +|----|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------|-----------------|----------|---------------------------------------------------------------------| +| O1 | O-DU
→
Non-RT
RIC | Minimum, Average (linear), and Maximum Uplink SINR or Co-UE interference, Noise and External Interference Level per UE (MU-MIMO pair histogram (SINR range: -10 dB to + 30 dB) for 1,2, 3,..., K UEs) | Perce
nt | 1 .. 15
min. | [Dial22] | New
measurement
definition
New
measurement
reporting | +| O1 | O-DU
→
Non-RT
RIC | Percent time MU-MIMO UEs are at maximum TX power and < 5 PRB (Ref. [3]) | Perce
nt | 1 .. 15
min. | [Dial24] | New
measurement
definition
New
measurement
reporting | + +**Table 6.2.3.2-3. Dials for uplink MIMO quality** + +| | | | | | | | +|----|-------------------------|----------------------------------------------------------------------|-------------|-----------------|----------|---------------------------------------------------------------------| +| O1 | O-DU →
Non-RT
RIC | SU-MIMO Condition number in dB histogram (21 dB to 0 dB) | Perce
nt | 1 .. 15
min. | [Dial28] | New
measurement
definition
New
measurement
reporting | +| O1 | O-DU →
Non-RT
RIC | SU-MIMO Reported Rank distribution histogram (Rank = 1,...,Max Rank) | Perce
nt | 1 .. 15
min. | [Dial29] | New
measurement
definition
New
measurement
reporting | + +**Table 6.2.3.2-4. Dials for condition number** + +| | | | | | | | +|----|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------------|----------|---------------------------------------------------------| +| O1 | O-DU
→
Non-RT
RIC | MU-MIMO PRB Utilization Histogram | Percent | 1 .. 15 min. | [Dial30] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | Total PRB % Used Supporting MU-MIMO histogram | Percent | 1 .. 15 min. | [Dial31] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | MU-MIMO PDCP Volume histogram | Percent | 1 .. 15 min. | [Dial32] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | MU-MIMO DRB (DL and UL) Throughput Histograms (min., ave., and max.) (100 kbps, 200, kbps, etc. 10 Gbps) vs. Mu-MIMO layers (1,2,...,K) | Percent | 1 .. 15 min. | [Dial33] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | MU-MIMO Spectral Efficiency (8*PDCP Volume/(BW*PRB utilization), bits/sec./Hz histogram over measurement period, where BW = bandwidth, Hz) note: all parallel/paired PRBs count as one over a TTI | Percent | 1 .. 15 min. | [Dial34] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | SU-MIMO PRB distribution histogram | Percent | 1 .. 15 min. | [Dial35] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | SU-MIMO PDCP Volume (Mbytes) histogram | Percent | 1 .. 15 min. | [Dial36] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | SU-MIMO DRB (DL and UL) Throughput (Kbits/sec.) Histogram as a function of Mu-----MIMO layers (1,2,...,K) | Percent | 1 .. 15 min. | [Dial37] | New measurement definition
New measurement reporting | +| O1 | O-DU
→
Non-RT
RIC | SU-MIMO Spectral Efficiency (8*PDCP Volume/(BW*PRB) utilization ratio (bits/sec./Hz) histogram over measurement period, where BW = bandwidth, Hz) | Percent | 1 .. 15 min. | [Dial38] | New measurement definition
New measurement reporting | + +Table 6.2.3.2-5. Dials for spectral efficiency + +Similar to the measurement and monitoring objective of the “dials” section, the control of key parameters is the objective of the “knobs” section. This allows the value proposition of allowing each operator to satisfy their respective unique optimality criteria via emerging AI/ML technologies. + +Must have: Settable SU-MIMO only or MU-MIMO only mode per class of user (e.g., QCI) + +Must have: Specifiable threshold on condition number and SINR that dictates the scheduled SU-MIMO rank of any given user + +| | | | | | | | +|-----|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------|--------------|----------|-----| +| O1 | Non-RT RIC → O-DU | Operator shall be able to set any UE to either SU-MIMO only or MU-MIMO only by QCI threshold | integer | 1 .. 15 min. | [Knob13] | New | +| O11 | Non-RT RIC → O-DU | Set SU-MIMO Rank. The condition number (ratio of the max. eigenvalue to min. eigenvalue) shall be calculated internally in real time and allow the operator to set a threshold based on condition number that is used to take the UE reported SU-MIMO rank and convert to a gNB transmitted rank | integer | 1 .. 15 min. | [Knob14] | New | +| O1 | Non-RT RIC → O-DU | CSI-RS density (0.3, 1, 3, etc.) | Fixed point | 1 .. 15 min. | [Knob20] | New | + +**Table 6.2.3.2-6. Knobs for MIMO mode setting and beam commands** + +Note: It is FFS whether any of the listed measurements have any dependency on O-RU and if any information needs to be exchanged over O-RAN FH m-plane interface from O-RU to O-DU. + +##### O-RAN Entity roles: + +- 1) SMO & Non-RT RIC + - a) Collect existing configuration and performance data from RAN + - b) Trigger AI/ML Model training/update and deployment as necessary + - c) Apply MIMO pairing control recommendations from rApp via R1 and O1 interface using config management service. +- 2) O-CU nodes + - a) Report current configuration and performance data to non-RT RIC rApp via O1 interface if required. +- 3) O-DU nodes + - a) Report current configuration and performance data to non-RT RIC rApp via O1 interface. + - b) Apply MIMO pairing control related knobs based on rAPP recommendation. + +#### 6.2.3.3 Impact Analysis on O-RAN WGs + +*Editor’s note: This is an initial impact analysis as part of the WG1 UCTG work on mMIMO. The intention is to estimate the expected standardization effort within the O-RAN working groups. It is up to the WGs to decide how the mMIMO functionality should be specified in specifications of each WG, and whether it will be part of existing or new set of specifications.* + +##### WG1 (use cases, architecture) Impact + +- Update WG1 use case analysis report and use-case detailed specification with MU-MIMO pairing control use case. No impact to existing architecture. + +##### WG2 (Non-RT RIC, A1, R1) Impact + +- Assess impact to A1 and R1 interfaces and non-RT RIC architecture, including AI/ML training and deployment. +- Add new use cases and corresponding requirements and specifications in case there is an impact to A1 or R1 interfaces. + +##### WG5 (O-CU and O-DU) Impact + +- Assess impact on O-CU and O-DU support for dials and knobs described in the use-case. + +##### WG10 (SMO, O1) Impact + +- Assess impact with PM coordination group and IM/DM coordination group on support of proposed dials (measurements) and knobs (configuration IM/DM) and incorporation in existing O1 interface models, as well as any required coordination with 3GPP. + +Summary: A detailed analysis of the specification impact is to be completed. There is large specification impact to specify new proposed measurement definitions and measurement reporting. The impact of the required measurements and configurations will be reduced if they are already part of ongoing/upcoming O-RAN specifications (ffs) or are being considered for specification in other bodies such as 3GPP (ffs). + +# 7 Comparison and Conclusions + +This Technical Report presents the results of the pre-normative phase mMIMO work item. Multiple mMIMO optimization algorithms have been analyzed, including beam-based Mobility Robustness Optimization, Grid of Beam Optimization, Non-Grid of Beam Optimization, L1/L2 Beam Management Optimization, AI/ML assisted optimized SS Burst Set, DMRS and CSI-RS configuration. + +Beam-based Mobility Robustness Optimization (bMRO) is an autonomous self-optimizing algorithm that improves beam-based inter-cell mobility performance by applying beam-specific Cell Individual Offsets (CIO) on the handover triggers between neighbor cells, based on the analysis of beam-specific mobility-related counters. The bMRO algorithm might be hosted in Non-RT RIC or Near-RT RIC. Based in mobility KPIs forwarded to the RIC from the O-CU, the RIC configures the beam-based CIO in the O-DUs. Simulation based evaluation shows a significant reduction in too early and too late handovers as well as a reduction of the total UE outage and mobility failure rate, as well as a reduced number of ping-pong handovers. The gain was shown for a mixed mobility (UEs with 3 km/h and 30 km/h) scenario in an urban micro deployment according to 3GPP TR38.901. The computational complexity and signaling overhead are a multiple of that of the legacy cell-based MRO where the multiplier is the number of beams that are supported in a cell. Complexity and signaling overhead can be reduced by enhanced proprietary implementations, e.g., forming virtual groups of beams with similar characteristics. bMRO is suggested for normative standardization with the foreseen impact on O-RAN WGs as outlined in Section 3.3.3. There is a dependency on completion of 3GPP Rel.17 for the completion of stage 3 in O-RAN. + +Grid of Beam Optimization (GoB) provides an automated beam forming configuration tailored to the topology of the cell, the physical environment, as well as the distribution of users and traffic in a cell (e.g. wide beams might cover low-density areas while narrow beams might cover high-density areas). The output of the algorithm are the optimized GoB BF configurations, that are, the number of beams and either i) the beam directions, horizontal & vertical beam widths, and power allocation of beams, or ii) the beam weights, transferred via the Open Fronthaul interface. The GoB algorithm might be hosted in Non-RT RIC or Near-RT RIC. First trial results show that the ML based beam pattern optimization algorithm can adapt to the traffic distribution and hence provides a significant gain in terms of weighted downlink RSRP. Uplink throughput enhancements are also expected since SSB beams are used for uplink receive beamforming. The gain was shown for NR TDD at 3.5 GHz with 1 to 20 UEs either stationary or with drive tests in a shopping street scenario. Different options for input parameters have been identified in the pre-normative phase, which are not supported by existing O-RAN and 3GPP specifications. The output parameters are supported by the existing O-RAN Open Fronthaul specification (i.e. O-FH M-Plane, O-FH CUS-Plane). GoB is suggested for normative standardization with the foreseen impact on O-RAN WGs as outlined in Section 3.2.3, while the preferred option for input parameter still needs to be analyzed and selected. + +Non-GoB optimization makes use of AI/ML techniques to optimize the beamforming algorithm for each UE, depending on UE and cell conditions. Multiple beamforming algorithm options exist, including both Grid of Beams and Non-Grid of Beams, the latter typically involving beam weights being calculated based on SRS measurements. This itself comprises multiple different algorithm options, which can have differing relative performance depending on UE conditions, cell conditions, SRS configuration, etc. Therefore, it is important that the optimal choice of beamforming algorithm option is applied for each UE. The non-GoB use case takes into account that such beamforming algorithms are generally proprietary and vendor specific. Training is assumed to be cell-based, residing in non-RT RIC, making use of measurements reported from O-DU as well as enrichment data obtained externally, for example related to location and mobility. Inferencing is assuming to be hosted in an xApp in near-RT RIC, based on similar measurements as for training, the output of which is the control of the beamforming modes that should be applied for a given UE. The control may be specified separately for multiple MIMO options (e.g. SU and MU). The update rate is assumed to be 100s of ms, considerably slower than the MAC scheduling update rate. Initial simulation results for a simple SU-MIMO case demonstrate the opportunity for significant performance gains by tailoring beamforming mode to the UE conditions. Per-UE measurement reporting might be specified in 3GPP specifications (e.g. 3GPP TS37.320) and referred to in O1/E2 specifications with limited or no impact on O-RAN specifications. Or per-UE measurement reporting might be specified in O-RAN specifications with small impact on WG3 and potentially moderate impact WG5. Non-GoB is suggested for normative standardization with the foreseen impact on O-RAN WGs as outlined in 5.2.3. + +In yet another optimization approach, AI/ML assisted network-wide (multi-gNB/TRP) optimizations framework proactively and autonomously infers optimal configuration per gNB/TRP for SS Burst Set, DMRS and CSI-RS based on + +available measurements, observations, and PIs at different nodes of the 3GPP NR and/or O-RAN access and core network elements. One of the preferred options is to train the AI/ML model offline in the SMO/Non-Real Time RIC. Trained model might be hosted in Non-Real Time RIC or Near-Real Time RIC depending on the selected optimization problem. For SS Burst Set configuration optimization, offline trained AI/ML model can be deployed in Non-Real Time RIC as rAPP. Based on the KPIs, observations and measurements from E2 nodes over O1 interface, inferred optimal SS Burst Set configuration is applied to E2 nodes (O-CU and/or O-DU) over O1 interface. Numerical analysis-based data presented as use case feasibility analysis shows that optimal configurations have potential to improve per-gNB/TRP spectral efficiency through saving time-frequency resources for both FR1 and FR2 systems with multiple transceiver chains. One of the design goals of the AI/ML optimizer is that it should target to limit the impacts on other system performances (e.g., initial access latency, maximum mobility support etc.) through operator defined KPI constrained optimization technique. Impacts on the R1 interface. For both DMRS and CSI-RS configuration optimization use cases, Near-Real Time RIC is considered as one of the preferred model deployment options. Optimal configurations can be generation every few tens of ms when needed by the E2 nodes. These configurations are UE specific. Trained model uses measurements, observations and PI generated by E2 nodes to derive the inference and applies back to E2 nodes over E2 interface. Numerical calculation-based analysis shows that optimal configurations can improve per-gNB/TRP spectral efficiency noticeably through saving time-frequency resources for both FR1 and FR2 systems with multiple transceiver chains. One important aspect of the optimizer is to limit the impacts on other system performances (e.g., maximum mobility support, time-frequency tracking accuracy etc.) through KPI (operator specified) constrained optimization techniques. Computational complexity for all three use cases described in this section depends on the size of training data set (measurement, observations and KPI data set) and the type of algorithm used. AI/ML assisted optimized SS Burst Set, DMRS and CSI-RS configuration is suggested for normative standardization with the foreseen impact on O-RAN WGs as outlined in section 3.4.2.1.1 and section 3.4.2.2.1. + +L1/L2 Beam Management Optimization will contribute to improved network performance in terms of throughput and reliability by utilizing AI/ML techniques to enable RAN to make wiser decision on UE-specific beam management operations. The beam management optimization algorithm could be used to estimate or predict the quality of beams based on limited beam measurement reported from O-DU as well as enrichment information (e.g., UE position and velocity) obtained externally, which allows beam selection with high accuracy and ensures reliable radio link against blockage, especially in mmWave. The output of algorithm will be the optimized control/policy related to beam management operations, which may potentially involve the configuration of beam measurement/reporting, beam indication and beam failure recovery, could be further study in the normative phase. Initial simulation results which assumed high-mobility urban street scenario show that the AI/ML-based solution can ensure beam tracking accuracy while significantly reducing beam measurement overhead. Different deployment options were discussed and compared (e.g., the AI/ML model training and inference can be hosted in the Non-RT RIC and Near-RT RIC respectively, or the AI/ML model training can be hosted in Non/Near-RT RIC while the AI/ML inference can be hosted in the E2 Nodes), which demonstrate different strengths and weaknesses. L1/L2 Beam Management Optimization is suggested for normative standardization with the foreseen impact on O-RAN WGs as outlined in Section 4.2.3. + +## 7.1 Summary of Evaluation + +| | Solution | Means of evaluation | Summary of result | #of Input Parameters | #of Output Parameters | +|----|-----------------------|----------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------|--------------------------------------------------------------------| +| 1 | GoB Optimization | Trial results with 1 to 20 UEs, stationary or drive test, shopping street scenario | 8.2 dB gain of weighted RSRP | 1
(up to 3 options might be defined) | 1 | +| 2 | bMRO Optimization | Detailed multi-cell system level simulation (incl. UE L3 mobility, detailed timers etc.) | Gain against legacy MRO
58% less too-late HO
23% less too-early HO | 5 | 1 | +| 3a | GoB RRM SSB Opt. | Numerical RS overhead analysis based on available numerologies in the 3GPP NR | Max. potential gain (best vs. worst) numerology neglecting other impact | 9 | 1 + 6
(6 initialization) | +| 3b | GoB RRM DMRS Opt. | Numerical RS overhead analysis based on available numerologies in the 3GPP NR | Max. potential gain (best vs. worst) numerology neglecting other impact | 8 | 1 + 2
(2 initialization) | +| 3c | GoB RRM CSI-RS Opt. | Numerical RS overhead analysis based on available numerologies in the 3GPP NR | Max. potential gain (best vs. worst) numerology neglecting other impact | 8 | 1 + 2
(2 initialization) | +| 4 | L1/2 Beam Management | Urban street with 1 gNB @28 GHz, simplified UE mobility (60km/h fixed), different beam measurement periods | No loss of beam measurement accuracy even for reduced beam measurement period | 7 | 1
(output options ffs) | +| 5 | Non-GoB Optimization | Simplified, single cell simulation, Single suboptimum SU-MIMO fixed 2 layers mode (GoB vs. non-GoB mode) for 1 km/h and 120 km/h | Max. potential gain against a fixed suboptimum MIMO mode
1km/h: 2% av. & 60% 5%tile TP
120km/h: 14% av. & 141% 5%tile TP | 7 | 1 + 3
(2 initialization + 1 training)
(training config. ffs) | +| 6 | DL Tx Power Opt. | Simple single cell urban scenario at 2 GHz with 8 UEs with no inter-cell interference | Different SINR received at UEs using MU-MIMO is shown. No results otherwise. | 5 | 1 | +| 7 | MU-MIMO User Pairing | No | No | 40 | 16 | +| 8 | SU-/MU-MIMO Switching | No | No | 19 | 3 | + +Table 7.1-1: Summary of Evaluation + +## 7.2 Impact on standardization + +| | Solution | # of new measurement definitions | # of new measurement reporting | # of new output parameter definition 1) | # of new output parameter configuration 2) | O-RAN impact analysis | 3GPP impact analysis | Suggested split between 3GPP / O-RAN | +|----|----------------------|----------------------------------------|----------------------------------------|----------------------------------------------------|-------------------------------------------------------|-----------------------|-----------------------------------------|--------------------------------------------| +| 1 | GoB Optimization | 1 or 2 | 1 or 2 | 0 | 0 | Yes | Detailed analysis. | O-RAN refers to 3GPP spec for measurements | +| 2 | bMRO Optimization | 5 (currently discussed in 3GPP Rel.17) | 5 (currently discussed in 3GPP Rel.17) | 1 (currently discussed in 3GPP Rel.17) | 1 (currently discussed in 3GPP Rel.17) | Yes | Detailed analysis. Rel.17 work ongoing. | O-RAN refers to 3GPP spec for measurements | +| 3a | GoB RRM SSB Opt. | 4 | 6 | 0 | 1 + 1 (init.) | Yes | General analysis | O-RAN refers to 3GPP spec for measurements | +| 3b | GoB RRM DMRS Opt. | 2 | 5 | 0 | 1 + 2 (init.) | Yes | General analysis | O-RAN refers to 3GPP spec for measurements | +| 3c | GoB RRM CSI-RS Opt. | 3 | 6 | 0 | 1 + 2 (init.) | Yes | General analysis | O-RAN refers to 3GPP spec for measurements | +| 4 | L1/2 Beam Management | 1 (optional) | 4 | 0 | 1 | Yes | General analysis | 2 Options | +| 5 | Non-GoB Optimization | 0 | 5 | 1 + 3 (init. + training) | 1 + 2 (init. + training) | Yes | General analysis | 2 Options | +| 6 | DL Tx Power Opt. | 5 | 5 | 1 | 1 | ffs | ffs | ffs | +| 7 | MU-MIMO User Pairing | 40 | 40 | 16 | 16 | ffs | ffs | ffs | +| 8 | SU/MU-MIMO Switching | 19 | 19 | 3 | 3 | ffs | ffs | ffs | + +**Table 7.2-1: Impact on standardization** + +Note 1) An example for an output parameter definition is an Information Element as defined in the 3GPP RRC specification or any interface specification (e.g. Xn, NG). + +Note 2) An example for an output parameter configuration is an Information Element for gNB configuration as defined in the 5G Network Resource Model in 3GPP TS28.541. + +## 7.3 Synergies among new measurements (definition and/or reporting) + +| Name | Measured at which entity | UE or cell specific reporting | GoB Opt. | L1/2 Management | Beam | Non-GoB Opt. | SSB, CSI-RS, DM-RS Opt. | MIMO Optimization | Measurement synergies | +|----------------------------------------|--------------------------|-------------------------------|----------|-----------------|------|--------------|-------------------------|-------------------|-----------------------| +| CSI report (e.g CQI, PMI, RI, LI, CRI) | UE report | per UE | x | x | | | x | x (histogram) | 3 + 1 | +| Channel Covariance Matrix | O-DU | per UE | x | | | | | x | 2 | +| L1-RSRP (SSB or CSI based) | UE report | per UE | | x | | x | x | | 3 | +| L1-SINR (SSB or CSI based) | UE report | per UE | | x | | x | | x (histogram) | 2 + 1 | +| UL SRS RSRP | O-DU | per UE | | | | x | x | | 2 | + +**Table 7.3-1: Synergies among new measurements** + +Note 1: Table 7.3-1 is limited to new input measurements mentioned in multiple proposals. + +Note 2: The beam-based MRO proposal is not considered in Table 7.3-1, since it does not have commonalities in terms of input/output parameters with the other proposals. + +# Annex A Input and output data and its relation to 3GPP specification + +One of the objectives of the Massive MIMO pre-normative phase is to analyse and evaluate the set of input/output parameters for each Massive MIMO use case. Once identified, the impact on O-RAN specification as well as dependencies on 3GPP specifications should be analyzed. This annex provides some background information on how input/output parameters might relate to 3GPP specifications. + +3GPP defines a very large number of measurements. Among others, these include: + +- Layer 1 (PHY) UE and gNB measurements + - Signal strength and signal quality measurements + - TS 38.215 NR; Physical layer measurements +- Layer 2 (MAC) UE measurements + - Power headroom reporting and buffer status reporting + - TS 38.321 NR; Medium Access Control (MAC) protocol specification +- Layer 2 (MAC) gNB measurements + - Load, delay and packet loss rate measurements + - TS 38.314 NR; Layer 2 measurements +- Layer 3 (RRC) UE measurements + - Mobility measurements and measurement reporting + - TS 38.331 NR; Radio Resource Control (RRC); Protocol specification + +There are many more well-defined measurements often exchanged via peer to peer signalling embedded in various protocols. Over the generations 3GPP refined its specifications and extended the number of standardized measurements. For instance, the L2 gNB measurements have been specified with the introduction of 3GPP LTE. It can be assumed that most of the measurements as specified in 3GPP are implemented in the UE and at the network side. Besides the accurate specification for implementation, there are also extensive test specifications defined for each measurement, at least for UE measurement reporting. + +Besides the measurements as such, also means for reporting measurements and other metrics towards the management system are defined. Current 3GPP specifications define different types of metrics. Most relevant specifications in this perspective are: + +- TS 28.552 specifies 5G Performance Measurements (PMs). These are counters aggregated, e.g., per DU, CU or per core function, for example an AMF Function. An example is the “Number of Active UEs in the DL per cell” which provides information about the mean number of active UEs in a cell. +- TS 28.554 specifies 5G end to end Key Performance Indicators (KPIs). These specify further aggregation of the counters defined in TS 28.552. One example is the “maximum registered subscribers of network slice through AMF” (clause 6.2.6) where the subscribers in the AMF that are registered are aggregated per network slice. +- TS 37.320 and TS 32.422 specify trace and minimization of drive test (MDT). Trace logs are messages per UE and MDT reports are measurements per UE. The defined MDT measurements for RRC\_CONNECTED UEs are for instance RSRP, RSRQ, SINR, Power Headroom, PDCP SDU Data Volume, Average UE throughput, Packet Delay, Packet loss rate etc. Also logging of MDT measurements of RRC\_IDLE or RRC\_INACTIVE UEs are specified. + +O-RAN commonly uses 3GPP measurement definitions, measurement procedures, and data models as defined by the respective 3GPP specifications and by reusing defined data models such as defined YANG models. Some examples are: + +- O-RAN.WG1.O1-Interface.0-v04.00 + - Procedures for Performance Data File Reporting and for Performance Data Streaming are specified in 3GPP TS 28.532 + - The Information Object Classes (IOC) for collection of management data including PM, KPI, Trace and MDT are specified in 3GPP TS 28.622 (stage 2) and TS 28.623 (stage3). + +- Trace and MDT Management Services are specified in 3GPP TS 32.421, TS 32.422 and TS 32.423. The functions and procedures of Immediate and Logged MDT are described in 3GPP TS 37.320. +- O-RAN.WG3.E2SM-KPM-v02.00 + - Refers to measurement definitions provided in 3GPP TS 28.552 for NR and 3GPP TS 32.425 for LTE +- O-RAN: O-RAN.WG5.MP.0-v02.00 + - Performance data file reporting, data streaming and measurement job control as defined in O-RAN.WG1.O1-Interface.0-v04.00 +- O-RAN.WG5.O-CU-O1.0-v01.00 + - Fault Supervision Management Services of O1 Interface contains Fault Supervision MnS as specified in 3GPP TS28.545 + - AlarmList IOC and AlarmRecord data type refer to 3GPP TS28.622. The corresponding solution sets (stage 3) for YAML and YANG are specified in 3GPP TS 28.623 + - O-CU-CP and O-CU-UP follow 3GPP SA5 data models and YANG modules as specified in 3GPP TS28.541 + +Similar principles are applied for configuration / provisioning management, where services and data models from 3GPP (e.g. as defined in 3GPP TS 28.532 or 3GPP TS 28.541) are commonly reused over O-RAN interfaces such as O1 and E2. Some examples are: + +- O-RAN.WG3.E2SM-RC-v01.01.00 + - RAN Parameters for Control Action refer to RAN parameters defined in 3GPP specifications such as 3GPP TS 28.541, TS 38.331, TS 38.423 TS 38.463, TS 38.473 etc. +- O-RAN.WG5.O-CU-O1.0-v01.00 + - The SMO configuration of O-DU is based on 3GPP SA5 data models and YANG modules specified in 3GPP TS 28.541. +- O-RAN.WG5.MP.0-v02.00 + - The SMO configuration of O-CU-CP and O-CU-UP is based on 3GPP SA5 data models and YANG modules specified in 3GPP TS 28.541. + +# --- Annex ZZZ: O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN + +Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance's sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. + +Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or third party beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full force and effect. \ No newline at end of file diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2fd5eaeff22262dc085e14adfdb0ad2472ac9dc2 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd2727019ae96e80efda4964e1a871737c2c73277a978726969f55d0e5275c2f +size 4536 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/0bccbd7ce1060554ff357e9dc141e073_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/0bccbd7ce1060554ff357e9dc141e073_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0d37bfab60b2f963f9e25a9f07935302c914c576 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/0bccbd7ce1060554ff357e9dc141e073_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:34438e0b100b4759f6cebdcdacdc2b32765f822f8b29bf98608b6ce345ceeeb3 +size 120466 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/10a42a18a38b76dd4b996117e860e418_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/10a42a18a38b76dd4b996117e860e418_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd91ff768eab004ca7411674584e54596afe5bd2 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/10a42a18a38b76dd4b996117e860e418_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7ae166b05b9b7d924cb6ef3975483bb79996f9cb418c4f318c2cce67beced47e +size 223770 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/1d5bfae884319be5f0f61b95d816e842_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/1d5bfae884319be5f0f61b95d816e842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bd062220b6d9d8223fee443b35b914316ae2c424 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/1d5bfae884319be5f0f61b95d816e842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7cb7d6a1d247628bfc38744180abe966e18a2346d3594dcfafe3d49d961af2f1 +size 111859 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/40f048aba7868a86391ba3a55b937a2d_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/40f048aba7868a86391ba3a55b937a2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a9dd6936f4ae5956f28260a862ba01c70ed791fd --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/40f048aba7868a86391ba3a55b937a2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:18ef78d3e6deef3e0b4f922bf960c0a6ec1d4f588fc5c0412d2e93d887b699fd +size 98328 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/54adbd714437d30933f0ca66ec943b89_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/54adbd714437d30933f0ca66ec943b89_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..543f5b4e112303d45d183c0c8c741997e8ce2ef1 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/54adbd714437d30933f0ca66ec943b89_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a97e24a6ee371969d7b13dafb72761981e378e3d52796fb6cfaec33a193883d2 +size 90465 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3a71b98fcfc274b0603208cc5e23601d7fc924a --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84a0e505aa8e8fcec39c03736b466858a7c1ef91abe309cdd2974ee18257e23b +size 4531 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/7bce3527866b394e8a48a4054efd5745_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/7bce3527866b394e8a48a4054efd5745_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4ba655a128fa9e255cd86cca291fc09705ec9776 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/7bce3527866b394e8a48a4054efd5745_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:67c2990da3adaffd775a1ef946e09cf5ac930bb8c09a382b9e3d08d9ca5752aa +size 274165 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82827af191c934857f3a5a97842fa19fb4aa5978 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54f690c723a011f67b244eeda5cca1f67e7a7784e122d72a637cea1ca968c8f4 +size 4531 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/991d1fb6e4127a2297ce912f3597950d_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/991d1fb6e4127a2297ce912f3597950d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a18c320f9c879e1b7a6badd1a8ce0ab731d19525 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/991d1fb6e4127a2297ce912f3597950d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1dc1967aeafb23abc56c3d1e9f5d56e40a940958d0e8642170045c5160b1aa4a +size 221703 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/a8d13f7b9c731eaa374200d1d52ed67e_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/a8d13f7b9c731eaa374200d1d52ed67e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..42a4eba64dcb315feb9ef96fd861980652c95f83 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/a8d13f7b9c731eaa374200d1d52ed67e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c4af87c82691558e77cf8d7e280cf9f91f28bb64aca9241aa0f50f7299b0a5b5 +size 95187 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/add57e0ff7a88ee3fddbb7ba38478a03_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/add57e0ff7a88ee3fddbb7ba38478a03_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f1c451bf410c1f52cdabb410557420c1fdd282c4 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/add57e0ff7a88ee3fddbb7ba38478a03_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e2d0b29d4420d1847b8f11bbb280170ce2f01265597758f666b8770f7bdf6fd1 +size 289609 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/b4cc5b102f59b582a4944fa7abc83164_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/b4cc5b102f59b582a4944fa7abc83164_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..541dd45b194b3f7c2311bb20c5b1ed32d752ed86 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/b4cc5b102f59b582a4944fa7abc83164_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7fcdefe41266e10814aa51c05a52ed32cf02d29389e39e76f1114bf2a584b054 +size 4564 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/b62c9316992fef2ebc6c8c05fc9a2382_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/b62c9316992fef2ebc6c8c05fc9a2382_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4e9b1b62174ffbc8c06cd02be1499db54373eba0 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/b62c9316992fef2ebc6c8c05fc9a2382_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3a9a7da99e998ec7444b395ec4abe4f0dd0f8e63236df539ed88f6dbb35967a9 +size 195385 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/b6dcfbb97d231ec7334d281bbc3d4c69_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/b6dcfbb97d231ec7334d281bbc3d4c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7ec6e3a4e31218e893c0dd4632c093cf9711657 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/b6dcfbb97d231ec7334d281bbc3d4c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:26194603400e806363fbc96c68b99c51d7823d33edcd2743a49c8dc02c9ce219 +size 4512 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/c5cb51a6bd779a03ebdcada85f733449_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/c5cb51a6bd779a03ebdcada85f733449_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..436c17af160bb875d2c88c9407275949ca0e905e --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/c5cb51a6bd779a03ebdcada85f733449_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9fa525c29fdf02a6b99daf756f969115f52b0879f2b4d2271a57784b2abfe88b +size 151678 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/c9d4415cd9a8b69105c5f9fcc46c156c_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/c9d4415cd9a8b69105c5f9fcc46c156c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cc98f0d81a3533a938060a9226049fa6557b0160 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/c9d4415cd9a8b69105c5f9fcc46c156c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:44cb2a1379cc933421fccf0c5b3a1ed0112855f70d0a2e1b2986d9658f9753d9 +size 187584 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/d478eb83cfdc4c0fcbaa276165b3d1d4_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/d478eb83cfdc4c0fcbaa276165b3d1d4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8fabf3d89b808a92981a41d3a5446b8b1d83a581 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/d478eb83cfdc4c0fcbaa276165b3d1d4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a55cf057add81bac5208e738578b06871feea626854066f7ee84fdb6fc13c319 +size 4529 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/f466f33adf97bb1dd31a463abc2bd8f0_img.jpg b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/f466f33adf97bb1dd31a463abc2bd8f0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ade27d6c1222921931881d1d5d5f4067befeba76 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/f466f33adf97bb1dd31a463abc2bd8f0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5df7a4364a677c36b5b7cdba8647f524dd77165328363403c4d28841d2bb6261 +size 211593 diff --git a/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/raw.md b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..cfd347410791e59baa1d7d0f241e751e4f6173c8 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00/raw.md @@ -0,0 +1,1278 @@ + + +# --- **O-RAN Work Group 10 (OAM for O-RAN)****Topology Exposure and Inventory Management Services Use Cases and Requirement Specification** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|-------------------------------------------------------------------------|----| +| Foreword..... | 3 | +| Modal verbs terminology..... | 3 | +| 1 Scope ..... | 3 | +| 2 References ..... | 3 | +| 2.1 Normative references ..... | 3 | +| 2.2 Informative references..... | 4 | +| 3 Definition of terms, symbols and abbreviations ..... | 4 | +| 3.1 Terms..... | 4 | +| 3.2 Symbols..... | 5 | +| 3.3 Abbreviations ..... | 5 | +| 4 Use Case Description ..... | 5 | +| 4.1 O-RAN TE&IV Use Cases..... | 5 | +| 4.1.1 Use case 1: O-RAN network provisioning ..... | 5 | +| 4.1.2 Use case 2: Alarm query with TE&IV services ..... | 13 | +| 4.1.3 Use case 3: Terminate NF Deployment on O-Cloud ..... | 15 | +| 4.1.4 Use case 4: Topology based alarm correlation ..... | 19 | +| 4.1.5 Use case 5: O-RAN Network Planning..... | 22 | +| 4.1.6 Use Case 6: NF Deployment Homing based on TE&IV services..... | 24 | +| 4.1.7 Use Case 7: TE&IV Updates related to O-Cloud-Provisioning..... | 26 | +| 4.1.8 Use case 8: Handling Cloud Site Outage Using TE&IV Services ..... | 30 | +| 5. Requirements..... | 33 | +| 5.1 Functional Requirements..... | 33 | +| 5.2 Non-Functional Requirements..... | 34 | +| 5.3 Dependencies ..... | 34 | +| Annex A (informative): ..... | 35 | +| Change History ..... | 37 | + +--- + +# --- Foreword + +This Technical Specification (TS) has been produced by WG10 of the O-RAN Alliance. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document specifies new use cases and refines existing use cases present in O-RAN specifications for Topology Exposure and Inventory Management. For each use case, the document describes the motivation, resources, steps involved and the data requirements. The functional and non functional requirements for Topology Exposure and Inventory Management services are derived from the use cases that further serve as a basis for specifying the topology and inventory models, services and APIs. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] 3GPP TS 23.032: "3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Universal Geographical Area Description (GAD) (Release 17)" + +- [2] O-RAN TS: "Topology Exposure & Inventory Common Information Models and Interface Specification - Stage 2" + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications" +- [i.2] O-RAN-WG10.OAM-Architecture-v07.00: "O-RAN Operations and Maintenance Architecture v07.00" +- [i.3] 3GPP TS 28.541: "5G Network Resource Model (NRM); Stage 2 and Stage 3 (Release 17)" +- [i.4] O-RAN.WG6.O2-GA&P-R003-v03.00:"O2 Interface General Aspects and Principles" +- [i.5] O-RAN.WG6.O2IMS-INTERFACE-v03.00: "O2ims Interface Specification" +- [i.6] O-RAN.WG2.R1UCR-R003-v03.00: "R1interface: Use Cases and Requirements" +- [i.7] O-RAN.WG4.MP.0-R003-v11.00: "O-RAN Working Group 4 (Open Fronthaul Interfaces WG) Management Plane Specification" +- [i.8] O-RAN.WG10.O1-Interface.0-R003-v10.00: "O-RAN Operations and Maintenance Interface Specification" +- [i.9] O-RAN.WG6.ORCH-USE CASES-R003-v06.00: "O-RAN Working Group 6 Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN" +- [i.10] O-RAN.WG6.CADS-v04.00 – "Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN" + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in [i.1] and the following apply: + +**Inventory:** Inventory consists of information about planned, active and available networks, resources, services, their states, relationships, and specific properties. + +**Topology:** Topology consists of information about relationships and characteristics of services and resources, derived from inventory and from other SMO services. + +**RAN Resources:** RAN resources includes GNBDUFunction, GNBCUCPFunction, GNBCUUPFunction, NRCellICU, NRCellIDU, NRSectorCarrier, NRCellRelation, NRFreqRelation, NRFrequency etc., as described in 3GPP 5G NRM [i.3], other ORAN NFs as described in [i.2]. + +**NF Deployment:** Based on term usage in [i.4], NF Deployment covers O-DU, O-CU-UP, O-CU-CP, near-RT RIC deployments in the O-Cloud. + +**O-Cloud Resources:** O-Cloud Resources include O-Cloud IMS model elements as depicted in the O-RAN IMS Interface [i.5]. + +**TE&IV resources:** TE&IV resources depict RAN resources, O-Cloud resources, and relationships with other RAN or O-Cloud resources etc., represented in topology and inventory models. + +**Planned inventory:** Represents the physical, logical, and virtual resources, their state, specific properties, and relationships, reserved for planned network realization. + +**TE&IV Service Producer:** The SMO Functions providing the TE&IV services and managing the inventory objects in the TE&IV Repositories. + +**TE&IV Service Consumer:** The SMO Consumer which uses TE&IV services. + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +TE&IV: Topology Exposure and InVentry management + +# --- 4 Use Case Description + +## 4.1 O-RAN TE&IV Use Cases + +### 4.1.1 Use case 1: O-RAN network provisioning + +#### 4.1.1.1 Background and goal of the use case + +The O-RAN Provisioning use case in WG10 OAM Architecture Specification [i.2] describes the sequence of steps to deploy and provision O-RAN NFs on physical/virtualized resources by leveraging the SMO Framework and O-Cloud management entities. + +The goal of this use case is to highlight the role of Topology Exposure (TE) and Inventory Management (IV) services during provisioning of O-RAN NFs. This use case leverages flows of O-RAN provisioning use case and highlights the interactions of O-RAN entities with TE&IV service producer. These interactions are for CRUD operations on inventory objects corresponding to the newly deployed NFs. + +NOTE: Throughout this document, as defined in [i.9], the term NF implies that it can be deployed as one of PNF or cloudified NF. A cloudified NF can be realized via one or many NF Deployments, as per [i.9], which can be a VNF or a CNF. + +#### 4.1.1.2 Entities/resource involved in the use case + +The SMO Framework leverages TE &IV services within the SMO. TE&IV services maintain the state of O-RAN NFs in the TE&IV repositories, which will be used by TE&IV Service Consumers within the SMO Framework to derive the contextual information of the network. TE&IV services support CRUD operations on inventory objects in TE&IV repositories and interactions with TE&IV Service Consumers. + +#### 4.1.1.3 Solutions + +**Table 4.1.1.3-1: O-RAN network provisioning** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|---------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | O-RAN network provisioning using TE&IV services | | +| Actors and Roles |
  • [1]. Service Management and Orchestration Framework: TE&IV Service Producer and TE&IV Service Consumer (such as Non-RT RIC Services, RAN NF OAM Services, O-Cloud Resources Management and Orchestration Services)
  • [2]. O-Cloud: DMS
  • [3]. PNF (e.g., O-RU, O-DU)
  • [4]. VNF (e.g., Near RT-RIC, xApps, O-CU-CP, O-CU-UP)
  • [5]. Consumers of the SMO services which are authorized to use TE&IV Service Producer services
| | +| Assumptions | Common Topology and Inventory Model is available in TE&IV Service Producer
EXAMPLE: For the purpose of this use case, the TE&IV inventory objects follow the Inventory object status values highlighted in Annex A | | +| Pre-conditions |
  • [1]. O-RAN Service Design completed as per WG10 OAM Architecture Specification Clause 4.2.1.3
  • [2]. O-RAN Network Planning completed as per Clause 4.1.5.3 and inventory objects are created with status as Planned
  • [3]. The PNF is constructed/installed and ready to be registered and Activated
  • [4]. The cloudified NF Software Package has been uploaded to the O-Cloud
  • [5]. Secure network connectivity is already available between RAN components
  • [6]. O-DU and O-RU are PNFs and the inventory objects corresponding to these RAN Nodes are available in the TE&IV repositories with a Planned status and ready to be registered and activated
  • [7]. On boarding of cloudified NF Descriptors to the O-Cloud is completed
  • [8]. TE&IV Service Producer is ready to accept requests from TE&IV Service Consumers
| | +| Begins when | The personnel authorized for initiating the Network provisioning operation, decides to deploy an O-RAN network in specific geo-location e.g., location identified using TE&IV services. Refer to WG10 OAM Architecture Specification Clause 4.2.1.3 for details. | | +| O-RAN Service Deployment | | | +| Step 1 (M) | TE&IV Service Consumer sends a query to the TE&IV Service Producer to get Planned O-RAN Service inventory objects | | +| Step 2 (M) | Response from TE&IV Service Producer with details of the Planned inventory objects | | +| Step 3 (O) | TE&IV Service Consumer updates the inventory objects with deployment specific parameter values. The request also transitions the O-RAN Service inventory object status to Assigned.
NOTE: It is assumed that any resource reservation if required is carried out at this stage | | +| Step 4 (O) | Confirmation of successful inventory object update in TE&IV Repository | | +| | Deployment details of the O-RAN Service is omitted. Refer to the deployment details of cloudified NF and PNF described below in steps 4.1.1 to 4.1.6 (for cloudified NF) and 4.2.1 to 4.2.4 (for PNF Registration) | | +| Step 5 (M) |

In case of a successful deployment of the O-RAN Service, the TE&IV Service Consumer sends a request to TE&IV Service Producer to update the inventory object with the details of the O-RAN Service being deployed and the status of the corresponding inventory object is changed to Deployed.

In case of a failure in deployment of O-RAN Service, the status of the O-RAN Service inventory objects remains Assigned so that the deployment can be re-initiated without repeated assignment of parameter values. The use case flow stops with the deployment failure. The subsequent flows are continued once the retry results in a successful deployment.

| | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|----------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Step 6 (M) | Confirmation of the status update on O-RAN Service Inventory Object in TE&IV Repository | | +| Step 7 (M) |

After completion of the RAN Node deployment, once the status of the associated inventory objects are updated as Deployed, the O-RAN Service activation is initiated.

Refer to steps 4.1.7 to 4.1.10 for details of the cloudified NF and steps 4.2.5 to 4.2.8 for PNF.

On successful completion of RAN Node activation, the status of the O-RAN Service inventory object is transitioned to Active.

In case the O-RAN Service activation failed (or if any of the RAN Node activation failed), the status remains in Deployed. The use case flow stops with the activation failure of O-RAN Service. The subsequent flows are continued once the retry results in a successful activation.

| | +| Step 8 (M) | Confirmation of the status update on O-RAN Service Inventory Object in TE&IV Repository | | +| 4.1 Cloudified NF Deployment and Activation | | | +| | For the cloudified NF (e.g., O-CU-CP, O-CU-UP, Near-RT RIC, xApps etc.) deployment details refer to WG10 OAM Architecture Specification Clause 4.2.1.3 Steps 5-10 | | +| Step 4.1.1 (O) | For the deployment of Cloudified NF (i.e VNF or CNF), the TE&IV Service Consumer retrieves planned inventory from TE&IV Repository | | +| Step 4.1.2 (O) | TE&IV Service Producer responds with the Planned inventory details. | | +| | Steps 11 - 18 is repeated for each cloudified NF deployed | | +| Step 4.1.3 (O) | TE&IV Service Consumer updates the inventory objects with deployment specific parameter values. The status of the RAN Node inventory object is updated as Assigned. | | +| Step 4.1.4 (O) | Confirmation of the RAN Node inventory object update in TE&IV Repository | | +| Step 4.1.5 (O) | Once deployment of the RAN Node is completed, on successful completion TE&IV Service Consumer updates the RAN Node inventory object with deployment details and the status is changed to Deployed. In case of a failure in the deployment of the RAN Node, the status remains as Assigned so that the re-deployment can be initiated without re-assignment of the inventory object parameter values. | | +| Step 4.1.6 (M) | Confirmation of the Status update of RAN Node as Deployed in TE&IV Repository | | +| Step 4.1.7 (M) | RAN Node is provisioned with the runtime configuration. On successful completion of the provisioning, the TE&IV Service Consumer updates the status of the RAN Node inventory object as Active. In case of a failure the inventory object remains in the Deployed state. | | +| Step 4.1.8 (M) | Confirmation of the Status update of RAN Node as Active in TE&IV Repository | | +| Step 4.1.9 (M) | Once the management and control plane connectivity is established with the RAN Node, the TE&IV Service Consumer updates the planned topology object with the updated inventory details | | +| Step 4.1.10 (M) | Confirmation of the Topology object update in TE&IV repository | | +| 4.2 PNF Registration & Activation | | | +| |

For the PNF (e.g., O-DU, O-RU) Deployment details refer to WG10 OAM Architecture Specification Clause 4.2.1.3 Steps 23-40 for details. Steps 19-26 are repeated for each PNF being deployed.

NOTE: PNF details are assumed to be part of the planned inventory which is retrieved by TE&IV Service Consumer in steps 1-2

| | +| Step 4.2.1 (O) | TE&IV Service Consumer updates the inventory objects with deployment specific parameter values such as the RAN Node identifier. The status of the RAN Node inventory object is updated as Assigned. | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Step 4.2.2 (O) | Confirmation of the RAN Node inventory object update in TE&IV Repository | | +| Step 4.2.3 (M) | Once the PNF is powered on and the discovery and registration process is completed, the TE&IV Service Consumer updates the status of the RAN Node as Deployed. | | +| Step 4.2.4(M) | Confirmation of the status update of RAN Node as Deployed in TE&IV Repository. In case of a failure in discovery or registration of the PNF, the status of the RAN Node Inventory object remains as Assigned. | | +| Step 4.2.5 (M) | After the registration of the PNF and once the provisioning of the PNF is successfully completed with the required runtime configuration, the TE&IV Service Consumer updates the status of the RAN Node inventory object as Active. In case of a failure in provisioning the PNF, the status of the inventory object remains as Deployed. | | +| Step 4.2.6 (M) | Confirmation of the status update of RAN Node as Active in TE&IV Repository | | +| Step 4.2.7 (O) | After the deployment and provisioning of RAN Node is completed, once the management and control plane connectivity are established with the RAN Node, the TE&IV Service Consumer updates the planned topology object with the updated inventory details | | +| Step 4.2.8 (O) | Confirmation of the Topology object update in TE&IV repository | | +| Post deployment validation/verification | | | +| | Post deployment Test details of NFs and O-RAN Service are omitted | | +| Step 9 (O)
(Continued from O-RAN Service Provisioning Step 8) | After the post deployment test execution and validation, the TE&IV Service Consumer sends request to get the status for the corresponding inventory objects | | +| Step 10 (O) | The status and other details of the inventory objects corresponding to RAN Nodes and O-RAN Service are provided and verified by the test executioner to certify and commission the deployment as successful or failure. | | +| Ends when | All O-RAN Network Functions needed for service have been deployed and configured with the status of inventory objects as Active. In case of a failure, the specific stages of the deployment or provisioning are repeated with associated changes in the deployment stages.
The SMO holds current inventory of all O-RAN network functions.
Post deployment test results of the RAN Nodes and O-RAN Service are verified against the corresponding inventory object status and Topology objects | | +| Exceptions | Not applicable | | +| Post Conditions | The O-RAN network has been established and provides service to customers | | +| Traceability | REQ -TE&IV-CRUDQ-FUN1, REQ -TE&IV-CRUDQ-FUN2, REQ -TE&IV-CRUDQ-FUN3, REQ-TE&IV-MODEL-FUN10 | | + +![Diagram of O-RAN Network Design and Planning TE&IV Operation showing personnel, service management framework, and planning steps.](0bccbd7ce1060554ff357e9dc141e073_img.jpg) + +The diagram illustrates the O-RAN Network Design and Planning TE&IV Operation. It is structured into three main horizontal sections separated by dashed lines. + +- Top Section:** A yellow box labeled "Service Management & Orchestration Framework". Inside, there are two yellow boxes: "TE&IV Service Producer" on the left and "TE&IV Service Consumer" on the right. To the left of this box is a blue box labeled "Personnel" containing a stick figure icon and the word "Consumer". +- Middle Section:** A white box with a grey header "ref". It contains the text: "O-RAN Service Design - Refer WG10 OAM Architecture Specification Clause 4.2.1.3, Step 1,2". +- Bottom Section:** A white box with a grey header "ref". It contains the text: "O-RAN NW Planning Refer Clause 4.1.5.3 (Create Planned Radio Network Objects and Transport Network Objects in TE&IV Repository)". Below this text is a yellow arrow pointing right, containing the text: "Radio and Transport Network Objects Created in TE&IV Repository , **Status as Planned**". + +Vertical dashed lines connect the "Consumer" in the Personnel box to the "TE&IV Service Producer" and "TE&IV Service Consumer" boxes in the top section, and to the "Consumer" in the bottom section. + +Diagram of O-RAN Network Design and Planning TE&IV Operation showing personnel, service management framework, and planning steps. + +**Figure 4.1.1.3-1: O-RAN Network Design and Planning TE&IV Operation** + +![Sequence diagram for O-RAN Service Deployment TE&IV Operations](991d1fb6e4127a2297ce912f3597950d_img.jpg) + +``` + +sequenceDiagram + participant Personnel as Personnel +Consumer + participant TEIV as TE&IV Service Producer + participant TEIVC as TE&IV Service Consumer + participant OCloud as O-Cloud + + Note over TEIV, TEIVC: O-RAN Service Deploy + ref O-RAN Service Deploy - Refer WG10 OAM Architecture Specification +Clause 4.2.1.3, Step 3,4 + TEIV->>TEIVC: 1 Get Planned O-RAN Service inventory objects + TEIVC-->>TEIV: 2 Response with Planned inventory objects + alt [If O-RAN Service is not assigned] + TEIV->>TEIVC: 3 Update O-RAN Service Inventory object parameters of O-RAN Service; +Status changed to Assigned + TEIVC-->>TEIV: 4 Confirmation of O-RAN Service inventory object update + else [If O-RAN Service Deployment Successful] + TEIV->>TEIVC: 5 Update O-RAN service inventory object , Status updated as Deployed (Reference O-RAN Service Inventory Identifier) + TEIVC-->>TEIV: 6 O-RAN Service inventory object Status changed to Deployed + else [O-RAN Service Deployment Failure] + Note over TEIV, TEIVC: O-RAN Service Inventory object Status remains Assigned + else [O-RAN Service Activation Successful] + TEIV->>TEIVC: 7 Update O-RAN service inventory object , Status updated as Active (Reference O-RAN Service Inventory Identifier) + TEIVC-->>TEIV: 8 O-RAN Service inventory object Status changed to Active + else [O-RAN Service Deployment Failure] + Note over TEIV, TEIVC: O-RAN Service Inventory object Status remains Deployed + end + end + Note over TEIV, TEIVC: Deployment of O-RAN Service completed + Note over TEIV, TEIVC: O-RAN Service activation completed + +``` + +The diagram illustrates the O-RAN Service Deployment TE&IV Operations. It involves three main components: Personnel (Consumer), TE&IV Service Producer, and TE&IV Service Consumer (O-Cloud). The process begins with the TE&IV Service Producer sending a request to the TE&IV Service Consumer to get planned O-RAN service inventory objects. The TE&IV Service Consumer responds with the planned inventory objects. An optional step occurs if the O-RAN service is not assigned, where the TE&IV Service Producer updates the O-RAN service inventory object parameters and the status is changed to Assigned. The TE&IV Service Consumer then confirms the update. If the O-RAN service deployment is successful, the TE&IV Service Producer updates the O-RAN service inventory object status to Deployed, and the TE&IV Service Consumer changes the status to Deployed. If there is a deployment failure, the status remains Assigned. If the O-RAN service activation is successful, the TE&IV Service Producer updates the O-RAN service inventory object status to Active, and the TE&IV Service Consumer changes the status to Active. If there is an activation failure, the status remains Deployed. The process concludes with the deployment of the O-RAN service and the completion of O-RAN service activation. + +Sequence diagram for O-RAN Service Deployment TE&IV Operations + +Figure 4.1.1.3-3: O-RAN Service Deployment TE&IV Operations + +![Sequence diagram for Cloudified NF Deployment TE&IV Operations](c9d4415cd9a8b69105c5f9fcc46c156c_img.jpg) + +The diagram illustrates the Cloudified NF Deployment TE&IV Operations across four main components: Personnel, Service Management & Orchestration Framework, Cloud Platform Infrastructure, and O-RAN Components. + +**Participants:** + +- Personnel:** Consumer (represented by a stick figure icon). +- Service Management & Orchestration Framework:** TE&IV Service Producer and TE&IV Service Consumer. +- Cloud Platform Infrastructure:** O-Cloud. +- O-RAN Components:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU, and O-RU. + +**Sequence of Operations:** + +- 4.1.1 Get Planned cloudified NF inventory objects**: Request from TE&IV Service Producer to TE&IV Service Consumer. +- 4.1.2 Response with Planned inventory objects**: Response from TE&IV Service Consumer to TE&IV Service Producer. +- [foreach cloudified NF instantiated]**: Loop structure for processing each cloudified NF. +- [If RAN Node inventory object is not assigned with required deployment parameters]**: Conditional block. + - 4.1.3 Update deployment specific RAN Node Inventory Parameters; Status changed to Assigned**: Request from TE&IV Service Producer to TE&IV Service Consumer. + - 4.1.4 Confirmation of inventory object update for RAN Node; Status changed to Assigned**: Response from TE&IV Service Consumer to TE&IV Service Producer. +- [Success]**: Path for successful status update. + - 4.1.5 Update inventory object of RAN Node : Status updated as Deployed (Reference RAN Node Inventory Identifier)**: Request from TE&IV Service Producer to TE&IV Service Consumer. + - 4.1.6 Confirmation of Status updated as Deployed**: Response from TE&IV Service Consumer to TE&IV Service Producer. + - [Failure]**: Path for failure. + - RAN Node Inventory Object Status remains Assigned**: Message from TE&IV Service Consumer to TE&IV Service Producer. +- [Success]**: Path for successful status update. + - 4.1.7 Update inventory object of RAN Node : Status updated as Active (Reference RAN Node Inventory Identifier)**: Request from TE&IV Service Producer to TE&IV Service Consumer. + - 4.1.8 Confirmation of Status updated as Active**: Response from TE&IV Service Consumer to TE&IV Service Producer. + - [Failure]**: Path for failure. + - RAN Node Inventory Object Status remains Deployed**: Message from TE&IV Service Consumer to TE&IV Service Producer. +- [Update topology object]**: Conditional block. + - 4.1.9 Update Topology object with RAN Node inventory details**: Request from TE&IV Service Producer to TE&IV Service Consumer. + - 4.1.10 Topology object update complete**: Response from TE&IV Service Consumer to TE&IV Service Producer. + +**Summary Messages:** + +- Instantiation of RAN Nodes completed**: Message from O-Cloud to O-RAN Components. +- Activation of RAN Nodes completed**: Message from O-Cloud to O-RAN Components. +- Management/Control plane connectivity established with RAN Node**: Message from O-Cloud to O-RAN Components. + +Sequence diagram for Cloudified NF Deployment TE&IV Operations + +Figure 4.1.1.3-4: Cloudified NF Deployment TE&IV Operations + +![Sequence diagram for PNF Deployment TE&IV Operations](f466f33adf97bb1dd31a463abc2bd8f0_img.jpg) + +The diagram illustrates the PNF Deployment TE&IV Operations across four main functional areas: Personnel, Service Management & Orchestration Framework, Cloud Platform Infrastructure, and O-RAN Components. + +**Participants:** + +- Personnel:** Consumer (represented by a stick figure icon). +- Service Management & Orchestration Framework:** TE&IV Service Producer and TE&IV Service Consumer. +- Cloud Platform Infrastructure:** O-Cloud. +- O-RAN Components:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU, and O-RU. + +**Sequence of Operations:** + +- ref:** O-RAN Service Deploy - Refer WG10 OAM Architecture Specification Clause 4.2.1.3, Steps 23-40. +- loop [for each PNF deployed]:** + - opt [if RAN Node Inventory object is not assigned with required parameters]:** + - 4.2.1 Update deployment specific RAN Node Inventory object parameters; **Status updated as Assigned** + - 4.2.2 Confirmation of inventory object update for RAN Node; **Status changed to Assigned** + - alt [Success]:** + - 4.2.3 Update RAN Node Inventory Object (Reference RAN Node Inventory Identifier); **Status as Deployed** + - 4.2.4 Confirmation of RAN Node Inventory object; **Status updated as Deployed** + - [Failure]:** RAN Node Inventory Object **Status remains Assigned** +- alt [Successful provisioning of PNF]:** + - 4.2.5 Update RAN Node Inventory object (Reference RAN Node Inventory Identifier); **Status as Active** + - 4.2.6 Confirmation of RAN Node Inventory object; **Status updated as Active** +- [Failure]:** RAN Node Inventory Object **Status remains Deployed** +- opt [Update topology object]:** + - 4.2.7 Update Topology object with RAN Node inventory details + - 4.2.8 Topology object update complete + +**Key Milestones (Yellow Bars):** + + - Discovery and Registration of RAN Node completed + - Provisioning of RAN Node completed + - Management/Control plane connectivity established with RAN Node + +Sequence diagram for PNF Deployment TE&IV Operations + +Figure 4.1.1.3-5: PNF Deployment TE&IV Operations + +![Sequence diagram for testing deployed NF TE&IV Operations. The diagram shows a Personnel Consumer interacting with a Service Management & Orchestration Framework. The framework contains TE&IV Service Producer and TE&IV Service Consumer components. The test process involves sending a 'Test the deployed NFs' message, followed by a 'Test details omitted' message. An optional step '[View deployment status]' is shown, which includes a query (9) and a return (10) of inventory object status. Finally, the test results are compared against the deployment status.](1d5bfae884319be5f0f61b95d816e842_img.jpg) + +``` + +sequenceDiagram + participant Personnel as Personnel +Consumer + participant Framework as Service Management & +Orchestration Framework + participant Producer as TE&IV Service +Producer + participant Consumer as TE&IV Service +Consumer + + Personnel->>Framework: Test the deployed NFs + Framework-->>Personnel: Test details omitted + opt opt + Framework->>Producer: 9 Query status of inventory objects + Producer-->>Consumer: 10 Return status of inventory objects + end + Framework-->>Personnel: Test results are compared against deployment status + +``` + +Sequence diagram for testing deployed NF TE&IV Operations. The diagram shows a Personnel Consumer interacting with a Service Management & Orchestration Framework. The framework contains TE&IV Service Producer and TE&IV Service Consumer components. The test process involves sending a 'Test the deployed NFs' message, followed by a 'Test details omitted' message. An optional step '[View deployment status]' is shown, which includes a query (9) and a return (10) of inventory object status. Finally, the test results are compared against the deployment status. + +**Figure 4.1.1.3-6: Testing of deployed NF TE&IV Operations** + +#### 4.1.1.4 Required Data + +- A unique identifier is assigned during creation of TE&IV resource in the TE&IV repositories, which is returned by the TE&IV Service Producer in the response for create operation. +- Representation of TE&IV resources in the TE&IV repositories may include, but not limited to the following: + - Unique identifier, name, lifecycle state of the resource etc. + +### 4.1.2 Use case 2: Alarm query with TE&IV services + +This use case is improvement of alarm query use case specified in R1UCR [i.6] with TE&IV services. + +This use case allows an rApp acting as service consumer to query identities of cells and NF Deployments in specific geo-location and then use retrieved identities to query alarm information. + +#### 4.1.2.1 Background and goal of the use case + +An rApp acting as service consumer can query from the RAN NF OAM information about an individual alarm, a set of alarms matching provided filtering criteria or all active alarms available in the alarm list. + +An rApp acting as TE&IV Service Consumer can query TE&IV Service Producer to get identities of cells and NF Deployments in specific geo-location. + +#### 4.1.2.2 Entities/resources involved in the use case + +- 1) RAN OAM-related functions + - a. Receives request to query alarm information, + - b. Responds with success or failure to the query of alarm information +- 2) rApp + - a. Initiates query of alarm information + - b. Initiates query to get identities of cells and NF Deployment in specific geo-location. +- 3) TE&IV Service Producer + - a. Exposes TE&IV services based on a Topology and Inventory Models and APIs, which offers among others the capability to provide the relationship between TE&IV resources and geo-location + - b. Consumes the data provided by the SMO functions (e.g., O1-related data, O2-related data, DME, SME) and exposes it via the Topology and Inventory Model and APIs. + +#### 4.1.2.3 Solutions + +**Table 4.1.2.3-1: Query alarm information use case using TE&IV services** + +| Use Case Stage | Evolution / Specification | <>
Related use case | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------| +| Goal | Query of alarm information of cells in a specific geo-location from RAN NF OAM using data from TE&IV services | | +| Actors and Roles | [1]. rApp in the role of service consumer that queries alarm information.
[2]. RAN NF OAM provides alarm information in response to the alarm queries
[3]. TE&IV Service Producer | | +| Assumptions | n/a | | +| Preconditions | The rApp is deployed and authorized to query RAN NF OAM and TE&IV Service Producer. Geo-location of cell and NF Deployment is available for query in the TE&IV Service Producer | | +| Begins when | The rApp determines the need to query alarm information from cells in specific geo-location | | +| Step 1 (M) | The rApp queries the TE&IV Service Producer for identities of cells and its associated NF deployments in specific geo-location | | +| Step 2 (M) | TE&IV Service Producer validates the request and retrieves cells and its associated NF deployments in specific geo-location from the TE&IV repositories. | | +| Step 3 (M) | TE&IV Service Producer returns the identities of cells and its associated NF Deployment instances. | | +| Step 4 (M) | The rApp queries alarm information from the RAN NF OAM by providing the rAppId, NF Deployment/Cells and optional query information that determines the requested result set. | | +| Step 5 (M) | The RAN NF OAM responds to the rApp with success along with the requested alarm information. | | +| Ends when | The rApp has successfully queried the alarm information | | +| Exceptions | n/a | | +| Post Conditions | n/a | | +| Traceability | REQ-TE&IV-MODEL-FUN6 | | + +![Sequence diagram for Query alarm information within the Service Management & Orchestration Framework. The diagram shows interactions between TE&IV Service Consumer, RAN NF OAM, and TE&IV Service Producer. Step 1: TE&IV Service Consumer sends 'Query for cells and NF Deployments in specific geo-location' to TE&IV Service Producer. Step 2: TE&IV Service Producer performs 'Request Validation' (indicated by a dashed arrow). A callout box states: 'Validates the request and retrieve cell and its associated NF deployments in specific geo-location from the TE&IV repositories'. Step 3: TE&IV Service Producer returns 'cell and its associated NF Deployments' to TE&IV Service Consumer. Step 4: TE&IV Service Consumer sends 'Query alarm information request (rAppld, NF Deployment, queryInfo)' to RAN NF OAM. A callout box with a 'ref' icon states: 'R1 Alarm Query - Refer WG2 R1UCR Specification Clause 8.1'. Step 5: RAN NF OAM sends 'Query alarm information response (alarmInfo)' to TE&IV Service Consumer.](54adbd714437d30933f0ca66ec943b89_img.jpg) + +Sequence diagram for Query alarm information within the Service Management & Orchestration Framework. The diagram shows interactions between TE&IV Service Consumer, RAN NF OAM, and TE&IV Service Producer. Step 1: TE&IV Service Consumer sends 'Query for cells and NF Deployments in specific geo-location' to TE&IV Service Producer. Step 2: TE&IV Service Producer performs 'Request Validation' (indicated by a dashed arrow). A callout box states: 'Validates the request and retrieve cell and its associated NF deployments in specific geo-location from the TE&IV repositories'. Step 3: TE&IV Service Producer returns 'cell and its associated NF Deployments' to TE&IV Service Consumer. Step 4: TE&IV Service Consumer sends 'Query alarm information request (rAppld, NF Deployment, queryInfo)' to RAN NF OAM. A callout box with a 'ref' icon states: 'R1 Alarm Query - Refer WG2 R1UCR Specification Clause 8.1'. Step 5: RAN NF OAM sends 'Query alarm information response (alarmInfo)' to TE&IV Service Consumer. + +**Figure 4.1.2.3-1: Query alarm information** + +#### 4.1.2.4 Required data + +TE&IV Service Producer has the relationship information about the cells and NF deployments associated with geo-location. + +The query request to TE&IV Service Producer contains the geo-location [1], cell type and NF Deployment type. TE&IV service returns identities of the requested cell and its associated NF deployment in the requested geo-location. + +The Query alarm information request contains the rAppld and optional query information. The query information determines the requested alarm information, for instance a single alarm with a particular alarm ID, all alarms in the alarm list or a subset of these alarms that match a set of filtering parameters. + +The Query alarm information response contains the requested alarm information scoped by the query information provided in the request. + +### 4.1.3 Use case 3: Terminate NF Deployment on O-Cloud + +#### 4.1.3.1 Background and goal of the use-case + +The goal of automation of lifecycle management of NFs is to attain service agility and lower operational costs in a service provider's network. Automated lifecycle management enables the service provider to deploy and terminate services within a short span of time. + +When services are terminated, the allocated resources and constituent NFs are terminated and become available for consumption by other services. + +This use case highlights the interaction of SMO with TE&IV services for deleting resources in the TE&IV repositories when NF Deployments are terminated on O-Cloud, based on the use case "Terminate Network Function on O-Cloud" in [i.9]. + +#### 4.1.3.2 Entities/resource involved in the use-case + +SMO: + +- TE&IV Service Producer - Exposes CRUD operations on TE&IV resources in TE&IV repositories +- SMOS Consumer (e.g., NFO) - Interacts with O-Cloud to perform life cycle management of NF Deployments + +O-Cloud: + +- DMS – Interacts with SMO for lifecycle management of NF Deployments + +#### 4.1.3.3 Solutions + +**Table 4.1.3.3-1: Terminate NF Deployment on O-Cloud** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | To delete an active NF from the TE&IV repository. This requires that the active NF is deactivated prior to termination of the NF deployment which allows for the deletion of the inventory object associated with the NF from the TE&IV repository. | | +| Actors and Roles | Network Function Install Project Manager
SMO: NFO, SMOS Consumer such as NFO, TE&IV Service Producer
O-Cloud: DMS
Network Function | | +| Assumptions |

[1]. The “Service Request” to the SMO includes the identifiers of the network function instance(s) to be terminated.

[2]. The Network Function Install Project Manager has subscribed to receive notifications from the SMO

[3]. The network function(s) to be terminated do not handle calls and do not provide services. SMOS Consumer (e.g., NFO) and DMS perform the needed actions for terminating the NFs on the O-Cloud

[4]. NF Termination is an asynchronous operation and SMOS Consumer notifies the TE&IV Service Producer about the termination status

EXAMPLE: For the purpose of this use case, the TE&IV inventory objects follow the inventory object status model values highlighted in Annex A

| | +| Pre-condition | [1]. SMO is available | | +| Begins when | Existing Network Function(s) are determined to be terminated on the O-Cloud and corresponding inventory object details are queried on TE&IV Service Producer | | +| Step 1 (M) | Network Function Install Project Manager requests NFO to terminate the network function instance(s) by providing the identifiers of the network function instance(s). | | +| |

For each NF deployment associated with each Network Function in the Service Request, the steps 2 to 8 are executed.

The details on how the SMOS Consumer and DMS perform the termination operation in O-Cloud is omitted. Refer to [i.9] clause 3.2.5 for more details.

NOTE: NF Termination is an asynchronous process that may go through multiple stages of operation. SMOS Consumer notifies TE&IV Service Producer when the NF is deactivated initially prior to graceful termination and resource deallocation.

| | +| Step 2 (M) | If TE&IV Service Producer subscribed to NF Deactivation events from SMOS Consumer, a notification is sent to TE&IV Service Producer indicating the deactivation status. | | +| Step 3 (M) | TE&IV Service Producer updates the resource inventory object status in the TE&IV repositories (e.g., from Active to Deployed). | | +| Step 4 (M) | TE&IV Service Producer sends the updated resource inventory object status to SMOS Consumer. | | +| Step 5 (M) | If TE&IV Service Producer has not subscribed to SMOS Consumer notification, a request to update the resource inventory object status is sent to TE&IV Service Producer and the corresponding status change is updated on the TE&IV repositories (e.g., from Active to Deployed). | | +| Step 6 (M) | Status of the inventory object update sent to SMOS Consumer. | | + +| | | | +|-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| | Steps 7 to 15 are for TE&IV Service operations after successful resource deallocation and termination of the NF in O-Cloud | | +| Step 7 (M) | If TE&IV Service Producer subscribed to SMOS Consumer notifications, the termination completion notification is received by the TE&IV Service Producer. | | +| Step 8 (M) | TE&IV Service Producer updates the status of the corresponding resource inventory object (e.g., Deployed to Assigned) | | +| Step 9 (M) | Status of the inventory object update sent to SMOS Consumer | | +| Step 10 (M) | If TE&IV Service Producer has not subscribed to TE&IV Service Consumer notification, a request to update the resource inventory object status is initiated by SMOS Consumer. The TE&IV Service Producer updates the resource inventory object status in TE&IV repositories (e.g., Deployed to Assigned) | | +| Step 11 (M) | Status of the inventory object update sent to SMOS Consumer | | +| Step 12 (O) | SMOS Consumer initiates request to delete the resource inventory objects from TE&IV repository | | +| Step 13 (O) | TE&IV Service Producer deletes the corresponding resources from TE&IV repositories | | +| Step 14 (O) | Status of the inventory object update sent to TE&IV Service Consumer | | +| Step 15 (M) | Based on the subscription of NF termination status notification, SMOS Consumer notifies the Network Function Install Project Manager that the Network Function(s) have been terminated. | | +| Ends when | Network Function(s) in the O-Cloud have been terminated. | | +| Exceptions | None identified | | +| Post Conditions | [1]. Network Function(s) have been terminated.
[2]. The consumer may unsubscribe to receive notification related to terminated NF instance(s) from SMO. | | +| Traceability | REQ -TE&IV-CRUDQ-FUN6 | | + +![Sequence diagram for NF Termination process](add57e0ff7a88ee3fddbb7ba38478a03_img.jpg) + +``` + +sequenceDiagram + actor Personnel as Personnel +Network Function Install +Project Manager + participant TEIV as TE&IV +Service Producer + participant SMOS as SMOS Consumer + + Note over Personnel, TEIV: Query Inventory object details for the NF(s) + TEIV->>SMOS: 1 Service request to terminate NF(s) with NF identifier(s) + Note over SMOS: SMOS Consumer (eg., NFO) and DMS perform needed actions to successfully terminate the NFs on O-Cloud. +Further details on how SMOS Consumer and DMS performs this operation is omitted in this use case + Note over SMOS: ref +Terminate Network Function on O-Cloud - +Refer i.9 Clause 3.2.5 + Note over SMOS: NF Termination is an asynchronous process and SMOS Consumer notifies TE&IV Service Producer when the NF is initially deactivated prior to termination + alt If TE&IV Service Producer subscribed for NF Deactivation events from SMOS Consumer (eg., NFO) + SMOS->>TEIV: 2 Notify NF deactivation status + Note over TEIV: Topology and Inventory Record State from "Active" to "Deployed" + TEIV->>SMOS: 3 Update Topology and Inventory Record + SMOS-->>TEIV: 4 Status of the Topology and Inventory object update + else SMOS Consumer informs TE&IV Service Producer of NF deactivation + Note over TEIV: Topology and Inventory Record State from "Active" to "Deployed" + TEIV->>SMOS: 5 Update Topology and Inventory Record + SMOS-->>TEIV: 6 Status of the Topology and Inventory object update + end + Note over TEIV, SMOS: NF Termination process along with resource deallocation is in progress (by SMOS Consumer/DMS) + Note over SMOS: NF Termination process is now completed along with resource deallocation by SMOS Consumer/DMS + alt If TE&IV Service Producer subscribed for NF termination events from SMOS Consumer (eg., NFO) + SMOS->>TEIV: 7 Notify NF termination status + Note over TEIV: Topology and Inventory Record State from "Deployed" to "Assigned" + TEIV->>SMOS: 8 Update Topology and Inventory Record + SMOS-->>TEIV: 9 Status of the Topology and Inventory object update + else SMOS Consumer informs TE&IV Service Producer of NF termination + Note over TEIV: Topology and Inventory Record State from "Deployed" to "Assigned" + TEIV->>SMOS: 10 Update Topology and Inventory Record + SMOS-->>TEIV: 11 Status of the Topology and Inventory object update + end + opt + TEIV->>SMOS: 12 Delete corresponding resources from Topology and inventory + TEIV->>SMOS: 13 Delete resources from inventory + SMOS-->>TEIV: 14 Response with status of Topology and Inventory object deletion + end + opt + SMOS->>Personnel: 15 Notify successful termination of NF instances + end + +``` + +**Personnel** +Network Function Install Project Manager + +**Service Management & Orchestration Framework** +TE&IV Service Producer +SMOS Consumer + +Query Inventory object details for the NF(s) + +1 Service request to terminate NF(s) with NF identifier(s) + +SMOS Consumer (eg., NFO) and DMS perform needed actions to successfully terminate the NFs on O-Cloud. Further details on how SMOS Consumer and DMS performs this operation is omitted in this use case + +ref +Terminate Network Function on O-Cloud - Refer i.9 Clause 3.2.5 + +NF Termination is an asynchronous process and SMOS Consumer notifies TE&IV Service Producer when the NF is initially deactivated prior to termination + +**alt** [If TE&IV Service Producer subscribed for NF Deactivation events from SMOS Consumer (eg., NFO)] + +2 Notify NF deactivation status + +Topology and Inventory Record State from "Active" to "Deployed" + +3 Update Topology and Inventory Record + +4 Status of the Topology and Inventory object update + +**[SMOS Consumer informs TE&IV Service Producer of NF deactivation]** + +Topology and Inventory Record State from "Active" to "Deployed" + +5 Update Topology and Inventory Record + +6 Status of the Topology and Inventory object update + +NF Termination process along with resource deallocation is in progress (by SMOS Consumer/DMS) + +NF Termination process is now completed along with resource deallocation by SMOS Consumer/DMS + +**alt** [If TE&IV Service Producer subscribed for NF termination events from SMOS Consumer (eg., NFO)] + +7 Notify NF termination status + +Topology and Inventory Record State from "Deployed" to "Assigned" + +8 Update Topology and Inventory Record + +9 Status of the Topology and Inventory object update + +**[SMOS Consumer informs TE&IV Service Producer of NF termination]** + +Topology and Inventory Record State from "Deployed" to "Assigned" + +10 Update Topology and Inventory Record + +11 Status of the Topology and Inventory object update + +**opt** + +12 Delete corresponding resources from Topology and inventory + +13 Delete resources from inventory + +14 Response with status of Topology and Inventory object deletion + +**opt** + +15 Notify successful termination of NF instances + +**Personnel** +Network Function Install Project Manager + +**Service Management & Orchestration Framework** +TE&IV Service Producer +SMOS Consumer + +Sequence diagram for NF Termination process + +**Figure 4.1.3.3-1: Terminate NF Deployment on O-Cloud** + +#### 4.1.3.4 Required Data + +TE&IV Service Producer may use the NF Deployment identifier to delete the inventory objects of the NF Deployments from TE&IV repositories. + +### 4.1.4 Use case 4: Topology based alarm correlation + +This use case provides the background, motivation, and requirements for Topology based alarm correlation, allowing operators to resolve or handle the alarms triggered through O1, O2 and M-Plane interface (in case of hybrid O-RU) using Topology Exposure and Inventory Management services, thereby reducing effort for root cause analysis of alarms. + +#### 4.1.4.1 Background and goal of the use case + +Faults are inevitable in big distributed system like O-RAN. Unhandled alarms will degrade the performance of the O-RAN network and will impact the users. It is important to quickly find the relationship between different alarms. Faults in O1 nodes are reported through O1 interface, faults in O-Cloud resources are reported through O2 interface and faults in the O-RU are reported through M-Plane interface. With disaggregated nature of O-RAN architecture, it becomes difficult to determine the relationship between alarms raised in O1 node or O-Cloud or O-RU. Topology and Inventory models with capability to show relationship between RAN resources, O-Cloud resources and transport resources is required to pinpoint the relationship between alarming resources. + +Sample scenario: Internal network switch failure in O-Cloud may impact NF Deployments which might affect the O-RAN network. Different alarms will be raised over O2, O1 and M-Plane interface as result of cascading effect of failure of an internal network switch in O-Cloud. + +Topology based alarm correlation can query the TE&IV Service Producer to understand the relationships between the topology/inventory resources and the alarmed resources. + +The objective of this use case is to leverage TE&IV services for alarm correlation to determine the root cause of a problem. + +#### 4.1.4.2 Entities/resource involved in the use case + +- 1) TE&IV Service Consumer (e.g., an rApp) + - a) Query the TE&IV Service Producer to get the relationship between alarmed resources +- 2) TE&IV Service Producer + - a) Exposes TE&IV services based on Topology and Inventory Models and APIs, which offers among others the capability to provide the relationship between resources provided by O1 nodes, O-Cloud and O-RU + - b) Consumes the data provided by the SMO functions (e.g., O1-related data, O2-related data, DME, SME) and exposes it via the Topology and Inventory Models and APIs + +#### 4.1.4.3 Solutions + +**Table 4.1.4.3-1 Topology based Alarm Correlation** + +| Use Case Stage | Evolution / Specification | <>
Related Use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------| +| Goal | Alarm correlation using TE&IV services | | +| Actors and Roles | [1]. TE&IV Service Consumer (e.g., an rApp)
[2]. TE&IV Service Producer | | +| Assumptions | [1]. All relevant functions and components are instantiated.
[2]. TE&IV services are supported and active in the SMO.
[3]. TE&IV Service Producer has an up-to-date view of the active alarm state list.
[4]. Some of the O-Cloud resource data that is volatile and frequently changed inside O-Cloud is not stored in TE&IV. | | +| Pre Conditions | Network is operational.
TE&IV Service Producer has an up-to-date view of the O-RAN network including RAN resources, NF Deployments, O-Cloud resources, and transport resources | | +| Begins when | Fault occurs in O-RU, O-DU, and O-Cloud
Several alarms are received by TE&IV Service Consumer | | +| Step 1 (M) | TE&IV Service Consumer queries the TE&IV Service Producer to get the NF Deployment instances using those O-Cloud resources that were indicated in the O-Cloud alarm resources | | +| Step 2 (M) | TE&IV Service Producer returns the data on the NF Deployment instances using the faulty O-Cloud resources to the TE&IV Service Consumer. | | +| Step 3 (M) | TE&IV Service Consumer queries the TE&IV Service Producer about the NF instances that were impacted by the O1 alarms | | +| Step 4 (M) | TE&IV Service Producer returns to the TE&IV Service Consumer the list of NF instances | | +| Step 5 (M) | TE&IV Service Consumer queries the TE&IV Service Producer to get the cells associated with impacted NF instances and connected O-RUs impacted by the M-Plane alarms. | | +| Step 6 (M) | TE&IV Service Producer returns to the TE&IV Service Consumer the list of impacted O-RUs and cells. | | +| Ends when | TE&IV Service Producer provided to the TE&IV Service Consumer all the requested data that correlated the faulty O-Cloud resources with the NF Deployment instances and ultimately with the cells that were using those O-Cloud resources. | | +| Exceptions | None Identified | | +| Post Conditions | TE&IV Service Consumer obtains the correlated alarm data between the faulty O-Cloud resources, O-RAN NFs, and the impacted cells. | | +| Traceability | REQ-TE&IV-MODEL-FUN1, REQ-TE&IV-MODEL-FUN2, REQ-TE&IV-MODEL-FUN3, REQ-TE&IV-MODEL-FUN4, REQ-TE&IV-MODEL-FUN5, REQ-TE&IV-MODEL-FUN7, REQ-TE&IV-MODEL-FUN8, REQ-TE&IV-MODEL-FUN9, REQ-TE&IV-CRUDQ-FUN3 | | + +![](b62c9316992fef2ebc6c8c05fc9a2382_img.jpg) + +**Service Management & Orchestration Framework** + +TE&IV Service Consumer | TE&IV Service Producer + +Use-case is triggered by alarms received from O2ims interface, O2dms interface, O1 interface and M-Plane interface within specific timeframe + +**Retrieval of NF Deployment Instances impacted by O2 Alarms** + +1 Query NF Deployment instances impacted by O2 alarms + +Retrieves from TE&IV repositories the NF Deployment relationships with O-Cloud resources as indicated in the O2 alarms + +Associations between NF Deployment instances to its NF instances are implementation specific + +2 Return list of NF Deployment instances using the faulty O-Cloud resources + +**Retrieval of NF Instances impacted by O1 Alarms** + +3 Query NF instances impacted by O1 alarms + +Retrieves from TE&IV repositories the NF instances as indicated in the O1 alarms + +4 Return list of associated NF instances impacted NFs by O1 alarms + +**Retrieval of NF Instances impacted by M-Plane Alarms** + +5 Query to retrieve cells associated with impacted NF instances and connected O-RUs impacted by the M-Plane alarm resources + +Retrieves from TE&IV repositories the cells and associated O-RUs impacted by M-Plane alarms + +6 Return list of impacted cells and associated O-RUs + +TE&IV Service Consumer obtains the correlated alarm data between the faulty O-Cloud resources, O-RAN NFs and the impacted cells. + +**Figure 4.1.4.3-1: Topology based Alarm Correlation** + +#### 4.1.4.4 Required data + +TE&IV Service Producer has the information about the O-Cloud resources, the O-RAN NFs, and their associated NF Deployments. + +TE&IV Service Producer has information regarding the relationship between O-Cloud resources, the O-RAN NFs, and their associated NF Deployments. + +TE&IV Service Producer has the connectivity relationships information + +- Between the O-RAN NFs +- Between the O-Cloud resources + +TE&IV Service Producer has the logical resource relationship of RAN resources. + +TE&IV Service Producer has the identity information of TE&IV resources which enables correlation of the different identities used across different functions in SMO. + +TE&IV Service Producer provides fault state and associated properties of the TE&IV resources to reflect the result of alarm correlation. + +### 4.1.5 Use case 5: O-RAN Network Planning + +#### 4.1.5.1 Background and goal of the use case + +Network planning enables CSPs to design, manage and optimize networks efficiently. Network planning and network design aim at ensuring that the new telecommunications network operates at optimum cost and has sufficient capacity and reliability to meet the needs of the subscriber and operator. With the advent of cloud native technologies and the ability to iterate and deploy quickly through containers, microservices etc., the time period between network planning and design to network deployment and realization has reduced significantly compared to the traditional process. + +The Inventory function supports the network planning process by storing and providing information regarding planned networks. TE&IV services enable bulk upload of network data to TE&IV repositories, which eases planning and deployment of large-scale networks. + +The objective of this use case is to illustrate the use of bulk upload services offered by TE&IV Service Producer during O-RAN network planning. + +NOTE: File format for bulk upload of network data is dependent on the common topology and inventory model and is not covered in this specification. + +#### 4.1.5.2 Entities/resource involved in the use case + +- 1) Service Management and Orchestration – Supports the deployment of O-RAN NFs. +- 2) TE&IV Service Consumer - Manages TE&IV resources related to O-RAN NF state and configuration in the TE&IV repositories. The TE&IV Service Consumer may be an existing SMO Decoupled SMO service such as Non-RT RIC Services, RAN NF OAM Services, O-Cloud Resources Management and Orchestration Services. +- 3) TE&IV Service Producer - Exposes the capability for bulk upload of network data in the TE&IV repositories. + +#### 4.1.5.3 Solutions + +**Table 4.1.5.3-1: O-RAN Network Planning** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Illustrate the role of TE&IV services in O-RAN network planning and deployment | | +| Actors and Roles |
  • [1]. Service Management and Orchestration Framework: TE&IV Service Producer, TE&IV Service Consumer
  • [2]. Consumers of the SMO Service such as Radio and Transport network designers, Radio and transport network planners, Field Technician, Network Operator
| | +| Assumptions |
  • [1]. The Service Management and Orchestration Framework and O-Cloud are connected and interact normally.
  • [2]. O-DU and O-RU are PNFs.

EXAMPLE: For the purpose of this use case, the TE&IV inventory objects follow the Inventory object status model values highlighted in Annex A

O-Cloud inventory objects planning may follow the same pattern as RAN network objects

| | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Pre-conditions |
  • [1]. Planning data for RAN, transport networks etc. are available in files in pre-defined format
  • [2]. Planning data has information about NF hierarchy, geo-location, O-Cloud Id for NF deployment etc.
  • [3]. PNFs are installed
  • [4]. Transport network is installed
  • [5]. O-Cloud supports platform and resource management normally
  • [6]. NF Software Package has been uploaded to the O-Cloud
  • [7]. O1 interface is configured between NFs and the SMO
  • [8]. TE&IV services are up and running in the SMO
  • [9]. TE&IV Service Consumers have subscribed for notifications regarding events related to creation of TE&IV resources in the TE&IV repositories
| | +| Begins when | Radio and Transport network planners decide to create a planned network in a specific geo-location based on finalized design from network designers | | +| Step 1 (O) | If the TE&IV Service Consumer is not subscribed to the RAN inventory create/update events, a subscription request is sent to the TE&IV Service Producer | | +| Step 2 (O) | TE&IV Service Producer confirms the subscription of RAN inventory object creation/update | | +| Step 3 (M) | SMO Service Consumer such as Radio planner upload the planned inventory details to the TE&IV Service Producer | | +| Step 4 (M) | TE&IV Service Producer creates RAN inventory objects and association as a part of planned in the TE&IV repositories as per uploaded data | | +| Step 5 (M) | TE&IV Service Producer acknowledges creation of the RAN inventory objects and associations as per uploaded data | | +| Step 6 (O) | TE&IV Service Producer notifies the subscribed TE&IV Service Consumers about the change in RAN inventory data | | +| Step 7 (O) | If the TE&IV Service Consumer is not subscribed to the Transport inventory object create/update events, a subscription request is sent to the TE&IV Service Producer | | +| Step 8 (O) | TE&IV Service Producer confirms the subscription of Transport inventory object creation/update | | +| Step 9 (M) | SMO Service Consumer such as Transport planner upload the planned inventory details to the TE&IV Service Producer | | +| Step 10 (M) | TE&IV Service Producer creates Transport inventory objects and association as a part of planned in the TE&IV repositories as per uploaded data | | +| Step 11 (M) | TE&IV Service Producer acknowledges creation of the RAN inventory objects and associations as per uploaded data | | +| Step 12 (O) | TE&IV Service Producer notifies the subscribed TE&IV Service Consumers about the change in Transport inventory data | | +| Ends when | The SMO holds up-to-date, active inventory of O-RAN NFs. | | +| Exceptions | None | | +| Post Condition | O-RAN network has been established and provides service to customers | | +| Traceability | REQ -TE&IV-CRUDQ-FUN1, REQ -TE&IV-CRUDQ-FUN4, REQ -TE&IV-CRUDQ-FUN5, REQ -TE&IV-BULK-FUN1 | | + +![Sequence diagram for O-RAN Network Planning showing interactions between Personnel, Service Management & Orchestration Framework, O-Cloud Platform Infrastructure, and O-RAN Components.](c5cb51a6bd779a03ebdcada85f733449_img.jpg) + +``` + +sequenceDiagram + participant Personnel as Personnel +Consumer + participant SMO as Service Management & Orchestration Framework + participant OCloud as O-Cloud Platform Infrastructure +O-Cloud + participant ORAN as O-RAN Components +O-RAN NFs + + SMO->>SMO: Create Radio network objects in planned inventory + opt SMO [If not subscribed] + SMO->>SMO: 1 Subscribe to RAN Network Inventory change events + SMO->>SMO: 2 Subscription accepted + end + Personnel->>SMO: 3 Prepare and upload RAN Planning data + SMO->>SMO: 4 Create RAN inventory objects as part of planned inventory. Status of the RAN inventory objects as "Planned" + SMO-->>Personnel: 5 Acknowledge creation of RAN objects + opt SMO [ ] + SMO->>SMO: 6 Notify subscriber(s) about creation of RAN NW objects + end + + SMO->>SMO: Create Transport network objects in planned inventory + opt SMO [If not subscribed] + SMO->>SMO: 7 Subscribe to Transport Network Inventory change events + SMO->>SMO: 8 Subscription accepted + end + Personnel->>SMO: 9 Prepare and upload transport planning data + SMO->>SMO: 10 Create transport inventory objects in planned inventory. Status of the Transport inventory objects as "Planned" + SMO-->>Personnel: 11 Acknowledge creation of transport objects + opt SMO [ ] + SMO->>SMO: 12 Notify subscriber(s) about creation of transport objects + end + + SMO->>SMO: Deployment and Activation of O-RAN Services,RAN Nodes + SMO-->>SMO: ref Refer to NW Provisioning use case, Clause 4.1.1.3 + +``` + +Sequence diagram for O-RAN Network Planning showing interactions between Personnel, Service Management & Orchestration Framework, O-Cloud Platform Infrastructure, and O-RAN Components. + +**Figure 4.1.5.3-1: O-RAN Network Planning** + +#### 4.1.5.4 Required Data + +- A unique identifier is assigned during the lifecycle of TE&IV resource in the TE&IV repositories, which is returned by the TE&IV Service Producer in the response for each TE&IV service operation. +- Representation of TE&IV resources in the TE&IV repositories may include, but not limited to the following: + - Unique identifier, name, lifecycle state of the resource etc. + +### 4.1.6 Use Case 6: NF Deployment Homing based on TE&IV services + +This use case provides the background, motivation, and requirements on TE&IV services for supporting NF Deployment use case with topology data. Specifically, to support queries from a TE&IV Service Consumer that is performing a NF Deployment homing decision. + +This use case shows how a TE&IV Service Consumer in SMO can use the topology information about planned and available O-Cloud resources retrieved from TE&IV Service Producer. + +#### 4.1.6.1 Background and goal of the use-case + +Orchestration use cases [i.9] involve homing decisions for NF Deployments into an appropriate O-Cloud Node Cluster. + +TE&IV services will provide the topology and inventory information of the O-Cloud resources across operator's RAN network, including both active and planned view. TE&IV Service Producer shall discover the O-Cloud capabilities and expose to TE&IV Service Consumer through models and APIs + +To satisfy the Network function orchestration use-cases [i.9], a TE&IV Service Consumer in SMO queries the TE&IV Service Producer to retrieve the required topology information of the O-Cloud resources across operator's network. + +#### 4.1.6.2 Entities/resources involved in the use-case + +- 1) TE&IV Service Consumer + - a) Queries TE&IV Service Producer to retrieve the relationships and properties of O-Cloud resources available across operator's network +- 2) TE&IV Service Producer + - a) Exposes TE&IV services based on Topology and Inventory Models and APIs, which offer, among others, the capability to provide the relationships between O-Cloud resources, RAN resources and NF Deployments. + - b) Consumes the data provided by the SMO functions (e.g., O2-related functions, DME, SME, etc) and exposes it via the Topology and Inventory Models and APIs + +#### 4.1.6.3 Solutions + +**Table 4.1.6.3-1 NF Deployment Homing based on TE&IV services** + +| Use Case Stage | Evolution / Specification | <> Related Use | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------| +| Goal | TE&IV Service Producer to provide the requested topology data to TE&IV Service Consumer containing information and relationships of the O-Cloud resources, RAN resources meeting the TE&IV Service Consumer query criteria. | | +| Actors and Roles | [1]. TE&IV Service Consumer
[2]. TE&IV Service Producer | | +| Assumptions | [1]. All relevant SMO functions and components are instantiated.
[2]. TE&IV services are supported and active in the SMO.
[3]. TE&IV Service Producer provides data to support TE&IV Service Consumer which is performing NF deployment homing. | | +| Pre Conditions | TE&IV Service Producer has an up-to-date view of the installed and running O-RU and connectivity including location information.
TE&IV Service Producer has the up-to-date view of the O-Cloud resources with their location information.
A TE&IV Service Consumer in SMO is handling homing decision for NF Deployments based on given application constraints (e.g. proximity to radio equipment), cloud resources (deploymentDescriptor) and operator constraints.
This use case only deals with TE&IV producer supporting with data required by the TE&IV consumer in its homing decisions. Therefore, the actual flow of the TE&IV consumer performing homing is out of scope for this use case.
TE&IV Service Producer is a consumer of RAN NF OAM and FOCOM services as indicated in the requirements identified in clause 5.2 | | +| Begins when | TE&IV Service Consumer determines it needs topology data to use as input to its NF Deployment homing decision. | | +| Step 1 (M) | TE&IV Service Consumer queries TE&IV Service Producer to get the identities of the O-Clouds and their O-Cloud Node Clusters and the O-RU locations at a given geographical coverage area. | | +| Step 2 (M) | TE&IV Service Producer validates the requests, retrieves the O-Cloud data, including their O-Cloud Node Clusters and O-RU information.
Among the topology data returned there are: the identities of the O-Cloud Node Clusters and their location attribute and O-RU information together with location information, adjacency and latency information, and other connectivity and topology related information. | | +| Step 3 (M) | TE&IV Service Producer returns the retrieved connectivity and location information of the O-Cloud, O-Cloud Node Clusters and O-RU to the TE&IV Service Consumer | | +| Step 4 (M) | TE&IV Service Consumer queries the infrastructure information of each of the O-Cloud Node Clusters it selected, to obtain their capabilities, the available resources, and the planned resources (in case any have already been planned for | | + +| | | | +|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| | this NF Deployment, as well as to see what resources have already been reserved) | | +| Step 5(M) | TE&IV Service Producer validates the requests, retrieves infrastructure information of the O-Cloud Node Clusters and returns the information to the TE&IV Service Consumer. | | +| Step 6 (M) | TE&IV Service Producer returns the retrieved O-Cloud Node Clusters infrastructure information to the TE&IV Service Consumer | | +| Ends when | TE&IV Service Consumer now has the up-to-date information on the O-Cloud resources available at the O-Cloud site(s) it selected, including both the capabilities and resources availability. | | +| Exceptions | n/a | | +| Post Conditions | n/a | | +| Traceability | REQ-TE&IV-MODEL-FUN2, REQ-TE&IV-MODEL-FUN3, REQ-TE&IV-MODEL-FUN4, REQ-TE&IV-MODEL-FUN6, REQ-TE&IV-MODEL-FUN7 | | + +![Sequence diagram for NF Deployment Homing based on TE&IV services. The diagram shows the interaction between a TE&IV Service Consumer and a TE&IV Service Producer within a Service Management & Orchestration Framework. The process starts with a sync of O-Cloud and RAN topology data. The consumer queries for O-Cloud identities and clusters. The producer retrieves this information from TE&IV repositories and returns connectivity and location data. The consumer then queries for infrastructure information of selected clusters, which the producer also retrieves from repositories and returns. Finally, the consumer has the latest information on O-Cloud resources.](a8d13f7b9c731eaa374200d1d52ed67e_img.jpg) + +``` + +sequenceDiagram + participant Consumer as TE&IV Service Consumer + participant Producer as TE&IV Service Producer + Note over Consumer, Producer: Sync with O-Cloud Topology and RAN Topology data + Consumer->>Producer: 1 Query to get the identities of the O-Cloud and their O-Cloud Node clusters and O-RU at the given geographical coverage area + Producer->>Producer: 2 Retrieve identities of O-Cloud, O-Cloud Node Cluster and O-Rus from TE&IV repositories + Producer-->>Consumer: 3 Return connectivity and location information of O-Cloud, O-Cloud Node Clusters and O-RU information + Consumer->>Producer: 4 Query the infrastructure information of the selected O-Cloud Node clusters, to obtain their capabilities, the available resources and the planned resources + Producer->>Producer: 5 Retrieve O-Cloud Node Clusters infrastructure information from the TE&IV repositories + Producer-->>Consumer: 6 Return the O-Cloud Node Clusters infrastructure information + Note over Consumer: TE&IV Service Consumer has the latest information on the O-Cloud resources available at the O-Cloud it selected, including both the capabilities and resources availabilities + +``` + +Sequence diagram for NF Deployment Homing based on TE&IV services. The diagram shows the interaction between a TE&IV Service Consumer and a TE&IV Service Producer within a Service Management & Orchestration Framework. The process starts with a sync of O-Cloud and RAN topology data. The consumer queries for O-Cloud identities and clusters. The producer retrieves this information from TE&IV repositories and returns connectivity and location data. The consumer then queries for infrastructure information of selected clusters, which the producer also retrieves from repositories and returns. Finally, the consumer has the latest information on O-Cloud resources. + +**Figure 4.1.6.3-1: NF Deployment Homing based on TE&IV services** + +#### 4.1.6.4 Required Data + +TE&IV Service Producer has the connectivity and location information of O-RU + +TE&IV Service Producer has the connectivity, infrastructure and location information of O-Cloud(s) and O-Cloud Node Clusters. + +### 4.1.7 Use Case 7: TE&IV Updates related to O-Cloud-Provisioning + +#### 4.1.7.1 Background and goal of the use-case + +This use case describes the creation of a single O-Cloud Node Cluster with O-Cloud Node addition(s), including addition of cluster capabilities. The creation of an O-Cloud Node request originates from FOCOM and is sent towards the IMS within the O-Cloud. The objective of the operation is to create the O-Cloud Node Cluster information in the TE&IV repositories using TE&IV services. The create operation initiated by FOCOM is part of a family of O2 IMS Provisioning operations related to O-Cloud Node Clusters [i.5]. + +This use case highlights the interaction of FOCOM with TE&IV Service Producer for creating the newly provisioned O-Cloud Node Cluster information in the TE&IV repositories. Based on either a polling (Request/Response) mechanism or event (Subscribe/Notify) mechanism. + +Further to a query or subscription request from TE&IV Service Consumer(s), the TE&IV Service Producer shall maintain and notify the latest status of the O-Cloud Node Cluster information to TE&IV Service Consumer(s). + +#### 4.1.7.2 Entities/resource involved in the use-case + +SMO: + +- TE&IV Service Producer +- TE&IV Service Consumer + +FOCOM + +- FOCOM - Is assumed to be inside the SMO but outside the same SMO Function as the TE&IV Service Producer. This module encapsulates the O2 IMS interface to the O-Cloud which requests the O-Cloud to create a planned O-Cloud Node Cluster + +#### 4.1.7.3 Solutions + +**Table 4.1.7.3-1 O-Cloud-Provisioning** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Have up-to date information in the TE&IV repositories about the O-Cloud Node Clusters. | | +| Actors and Roles | See clause 4.1.7.2 | | +| Assumptions |
  • [1]. O-Cloud is running
  • [2]. A request to create new O-Cloud Node Cluster is sent from FOCOM to IMS with the Inventory Cluster ID using O2 IMS Provisioning service.
  • [3]. FOCOM will successfully create the new O-Cloud Node Cluster based on the planned view in the O-Cloud infrastructure inventory.
  • [4]. The query request from the TE&IV Service Consumer to the TE&IV Service Producer is an asynchronous event
| | +| Pre-condition |
  • [1]. SMO is available.
  • [2]. In case Subscribe/Notify mechanism is used, the TE&IV Service Producer has previously subscribed to event notifications from FOCOM.
| | +| Begins when | The TE&IV Service Consumer intends to transition a planned Cluster Inventory to an active Cluster. | | +| Step 1 (M) | TE&IV Service Consumer sends a request to TE&IV Service Producer to get the details of a planned O-Cloud Node Cluster matching specific criteria. | | +| Step 2 (M) | TE&IV Service Producer returns the corresponding Node Cluster Inventory data | | +| Step 3 (M) | TE&IV Service Consumer after determining template parameter values for a new Node Cluster instance request an update of the Cluster inventory data to persist those variables. The Cluster inventory record is moved from "Planned" to "Assigned". | | +| Step 4 (M) | TE&IV Service Producer returns a status of the operation. For this use case it is assumed that the response indicates success. If the operation failed the state remains unchanged, thus the request can be re-issued once the failure problem has been remediated. | | +| NOTE: | The actual request to create the O-Cloud Node Cluster is done outside of the TE&IV Service Producer. In this use case it is assumed that the operation was successful. | | + +| | | | +|---------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| Step 5 (M)
Alternate
Subscribe/Notify | FOCOM sends asynchronous event to TE & IV Service Producer that a cluster has been created. The notification includes the Cluster Information and the Cluster Inventory Id for the inventory record for which it was created. | | +| Step 6 (M)
Alternate
Subscribe/Notify | TE&IV Service Producer updates the Cluster Inventory record identified by the Inventory Record Id with as built details from the Cluster Info moving it from a "Assigned" state towards "Deployed" state. | | +| Step 7 (M)
Alternate
Query/Response | TE&IV Service Consumer informs TE&IV Service Producer that an "Assigned" cluster identified by its Inventory Record Id has been created and the TE&IV Service Producer needs to update its inventory record based on the cluster identified by the Cluster Resource Id to indicate it is now "Deployed". | | +| Step 8 (M)
Alternate
Query/Response | TE&IV Service Producer requests the current Cluster Info from the FOCOM using the Cluster Resource Id | | +| Step 9 (M)
Alternate
Query/Response | FOCOM returns status [Success] and the cluster resource information to the TE&IV Service Producer | | +| Step 10 (M)
Alternate
Query/Response | TE&IV Service Producer updates the inventory record identified by the Inventory Record Id with as built details from the Cluster Info moving it from a "Assigned" state towards "Deployed" state. | | +| Step 11 (M)
Alternate
Query/Response | TE&IV Service Producer returns the status (success/fail) of the request to transition from "Assigned" to "Deployed" to the TE&IV Service Consumer. | | +| Step 12 (M)
Alternate
Notification | If the TE&IV Service Consumer has subscribed to change notifications and the inventory information for the O-Cloud Node Cluster was updated an asynchronous event is published by the TE&IV Service Producer to the TE&IV Service Consumer. | | +| Step 13 (M) | After ensuring the O-Cloud Node Cluster is ready for use by other SMO Functions the TE&IV Service Consumer requests an update to the Node Cluster inventory record to indicate it has transitioned from the "Deployed" state to the "Active" state. | | +| Step 14 (M) | TE&IV Service Producer returns a status of the operation. For this use case it is assumed that the response indicates success. If the operation failed the state remains unchanged, thus the request can be re-issued once the failure problem has been remediated. | | +| Step 15 (M) | SMOS Consumer requests the Node Cloud Cluster inventory details. | | +| Step 16 (M) | TE&IV Service Consumer sends a request to TE&IV Service Producer to get the details of a planned O-Cloud Node Cluster matching specific criteria. | | +| Ends when | TE&IV Service Producer returns the corresponding Node Cluster Inventory data | | +| Exceptions | None identified. | | +| Post Conditions | The TE&IV Service Producer shall maintain and notify the latest status of the O-Cloud Node Cluster information to TE&IV Service Consumer(s) based on future subscription requests. | | +| Traceability | REQ-TE&IV-CRUDQ-FUN1, REQ-TE&IV-CRUDQ-FUN2, REQ-TE&IV-CRUDQ-FUN3, REQ-TE&IV-CRUDQ-FUN4, REQ-TE&IV-CRUDQ-FUN5, REQ-TE&IV-MODEL-FUN3, REQ-TE&IV-MODEL-FUN5, REQ-TE&IV-MODEL-FUN8 | | + +![Sequence diagram showing the interaction between SMOS Consumer, TE&IV Service Producer, and FOCOM for cluster inventory management. The process includes querying, updating, and assigning inventory records, with state transitions from Planned to Assigned, Deployed, and Active. It also covers external consumer notifications and asynchronous queries.](7bce3527866b394e8a48a4054efd5745_img.jpg) + +**Service Management & Orchestration Framework** + +``` + +sequenceDiagram + participant SMOS as SMOS Consumer + participant TEIV as TE&IV Service Producer + participant FOCOM as FOCOM + + Note over SMOS, TEIV: Cluster inventory record was created in inventory as planned during planning. This includes the reference to the O-Cloud Template to be used for its creation. + SMOS->>TEIV: 1 Query Cloud Inventory + TEIV-->>SMOS: 2 Status [success] and requested Cluster Inventory Record + Note over TEIV: Inventory Record State is "Planned" + Note over SMOS: Template Parameter Values are identified and values are added to the inventory record + SMOS->>TEIV: 3 Update Cloud Inventory + Note over TEIV: Inventory Record State from "Planned" to "Assigned" + TEIV-->>SMOS: 4 Status + Note over SMOS, FOCOM: SMOS Consumer and FOCOM perform needed actions to successfully create the Node Cluster using the planned view data obtained from TE&IV producer. + Note over SMOS, FOCOM: Further details on how FOCOM and IMS provisions resources in the O-Cloud are omitted in this use case. + + alt [If TE&IV Service Producer subscribed to FOCOM Events] + FOCOM->>TEIV: 5 Receive Cloud Inventory Change Notification + TEIV->>SMOS: 6 Update Inventory Record + Note over TEIV: Inventory Record State from "Assigned" to "Deployed" + else [External consumer informs TE&IV of Cluster creation] + SMOS->>TEIV: 7 Assign Cluster Resource + TEIV->>FOCOM: 8 Cloud Infrastructure Query + FOCOM-->>TEIV: 9 Query Status + TEIV->>SMOS: 10 update Cluster Inventory Record + Note over TEIV: Inventory Record State from "Assigned" to "Deployed" + TEIV-->>SMOS: 11 Status + end + + alt [If Consumer has subscribed to inventory/topology change notification] + FOCOM->>SMOS: 12 Inventory Change Notification is sent + Note over SMOS: SMO Consumer ensures cluster is ready for use + SMOS->>TEIV: 13 Update Cloud Inventory + Note over TEIV: Inventory Record State from "Deployed" to "Active" + TEIV-->>SMOS: 14 Status + end + + Note over SMOS, FOCOM: The Query request from the TE&IV Service Consumer is assumed to be an asynchronous event + SMOS->>TEIV: 15 Query Cloud Inventory + TEIV-->>SMOS: 16 Status [success] and requested Cluster Inventory Record + Note over TEIV: Inventory Record State is "Active" + Note over TEIV: TE&IV Service Producer shall maintain and notify the latest status of the O-Cloud Node Cluster information to TE&IV Service Consumer(s) based on future subscription requests + +``` + +**Participants:** SMOS Consumer, TE&IV Service Producer, FOCOM + +**Sequence of Operations:** + +- SMOS Consumer queries Cloud Inventory from TE&IV Service Producer. +- TE&IV Service Producer returns Status [success] and requested Cluster Inventory Record to SMOS Consumer. (Inventory Record State is "Planned") +- SMOS Consumer updates Cloud Inventory on TE&IV Service Producer. (Inventory Record State from "Planned" to "Assigned") +- TE&IV Service Producer returns Status to SMOS Consumer. +- SMOS Consumer and FOCOM perform needed actions to successfully create the Node Cluster using the planned view data obtained from TE&IV producer. (Further details on how FOCOM and IMS provisions resources in the O-Cloud are omitted in this use case.) +- Alt Block:** + - Alt [If TE&IV Service Producer subscribed to FOCOM Events]:** FOCOM sends Receive Cloud Inventory Change Notification to TE&IV Service Producer, who then updates the Inventory Record on SMOS Consumer. (Inventory Record State from "Assigned" to "Deployed") + - Alt [External consumer informs TE&IV of Cluster creation]:** SMOS Consumer assigns Cluster Resource to TE&IV Service Producer, who queries Cloud Infrastructure from FOCOM, receives Query Status, updates Cluster Inventory Record on SMOS Consumer, and returns Status. (Inventory Record State from "Assigned" to "Deployed") +- Alt Block:** + - Alt [If Consumer has subscribed to inventory/topology change notification]:** FOCOM sends Inventory Change Notification to SMOS Consumer, who ensures cluster is ready for use, updates Cloud Inventory on TE&IV Service Producer, and receives Status. (Inventory Record State from "Deployed" to "Active") +- SMOS Consumer queries Cloud Inventory from TE&IV Service Producer. (The Query request from the TE&IV Service Consumer is assumed to be an asynchronous event) +- TE&IV Service Producer returns Status [success] and requested Cluster Inventory Record to SMOS Consumer. (Inventory Record State is "Active") +- TE&IV Service Producer shall maintain and notify the latest status of the O-Cloud Node Cluster information to TE&IV Service Consumer(s) based on future subscription requests. + +Sequence diagram showing the interaction between SMOS Consumer, TE&IV Service Producer, and FOCOM for cluster inventory management. The process includes querying, updating, and assigning inventory records, with state transitions from Planned to Assigned, Deployed, and Active. It also covers external consumer notifications and asynchronous queries. + +**Figure 4.1.7.3-1: O-Cloud-Provisioning** + +#### 4.1.7.4 Required Data + +TE&IV Service Producer has the connectivity, infrastructure and location information of O-Cloud(s) and O-Cloud Node Clusters. + +A unique identifier is assigned during creation of TE&IV resource in the TE&IV repositories, which is returned by the TE&IV Service Producer in the response for create operation. + +The unique identifier assigned during creation of TE&IV resource is in the Cluster Information provided by the FOCOM such that the TE&IV Service Producer can associate the O-Cloud Node Cluster with its corresponding inventory record. + +### 4.1.8 Use case 8: Handling Cloud Site Outage Using TE&IV Services + +#### 4.1.8.1 Background and goal of the use case + +Due to some outage or failure, a cloud site serving a node at a popular public event goes down. An rApp acting as a TE&IV Service Consumer monitoring this, uses TE&IV services to find out what O-RAN network function(s) will be impacted by this outage. The rApp is given only the details of the cloud site facing the outage through alarms generated by the cloud provider. For the rApp to identify the O-RAN Network Function instances, it would need to query TE&IV Service Producer to retrieve the list of topology attributes from the Cloud, the RAN, and the relationship between the RAN and the Cloud domains. + +Towards this goal, the rApp queries TE&IV Service producer to list the available NF Deployments from the Cloud namespace and its relationship to the O-RAN Network Function instances in the RAN namespace. Finally, the rApp queries the topology attributes in the RAN Namespace from the TE&IV Service Producer which would then be identified and recommended to an Orchestrator within the SMO to perform a rehomeing of the affected O-RAN Network Functions to a functional cloud site to avoid network disruption. + +The motivation of this use case is to highlight the role of TE&IV services in rehomeing O-RAN NFs to a viable cloud site to avoid network disruption at a popular public event. This use case leverages the O-RAN NF and O-Cloud models as outlined in [2], and the RAN-O-Cloud relationship exposed by TE&IV Service Producer. + +#### 4.1.8.2 Entities/resources involved in the use case + +- 1) TE&IV Service Consumer as rApp + - a) Queries TE&IV Service Producer to retrieve the relationships and properties of Cloud and RAN resources across operator's network. +- 2) TE&IV Service Producer + - a) Exposes TE&IV services based on Topology and Inventory Models and APIs, which offers among others the capability to provide the relationship between resources provided by Cloud and RAN. + - b) Consumes the data provided by SMO functions and exposes it via the Topology and Inventory Models and APIs. + +#### 4.1.8.3 Solutions + +**Table 4.1.8.3-1: Handling Cloud Site Outage Using TE&IV Services** + +| Use Case Stage | Evolution / Specification | <> Related Use | +|------------------|--------------------------------------------------------------------------------------------------------------------------------|---------------------| +| Goal | TE&IV Service Consumer (e.g., rApp) to rehome RAN Logical NFs to another Cloud Site to avoid disruption of a critical network. | | +| Actors and Roles | [1]. TE&IV Service Consumer (e.g., rApp)
[2]. TE&IV Service Producer | | + +| | | | +|-----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| Assumptions | TE&IV Service Producer synchronizes its repositories with the RAN and Cloud Topology information | | +| Pre Conditions |
  • [1]. Network is facing an imminent outage.
  • [2]. TE&IV Service Producer has an up-to-date view of the O-RAN network including RAN resources, NF Deployments, and O-Cloud resources
  • [3]. The rApp is deployed and authorized to query RAN NF OAM and TE&IV Service Producer. Geo-location of cell and NF Deployment is available for query in the TE&IV Service Producer
| | +| Begins when | TE&IV Service Consumer is notified of a set of alarms generated by a disruption in a cloud site related to NF Deployments | | +| Step 1 (M) | TE&IV Service Consumer queries TE&IV Service Producer for Cloud Site ID affected by the outage | | +| Step 2 (M) | TE&IV Service Producer traverses through the TE&IV Cloud topology information to retrieve the associated node clusters and NF deployments. | | +| Step 3 (M) | TE&IV Service Consumer queries TE&IV Service Producer for the associated NF Deployments serving the RAN logical NFs. | | +| Step 4 (M) | TE&IV Service Producer exposes the relationship between the RAN Logical NF instances and its associated NF Deployments. | | +| Step 5 (M) |

TE&IV Service Consumer queries the TE&IV Service Producer for the Topology attributes of the RAN Logical NF instance Topology entity.

NOTE: Steps 5 to 7 can be looped for each RAN Logical NF Instance

| | +| Step 6 (M) | TE&IV Service Producer responds with the list of Topology attributes for the RAN Logical NF instance Topology entity. | | +| Step 7 (O) | TE&IV Service Consumer requests additional RAN related information from various other sources | | +| Step 8 (M) | TE&IV Service Consumer analyses the RAN Logical NF instances associated to the affected NF Deployments | | +| Step 9 (M) | TE&IV Service Consumer performs the necessary tasks to rehome the NF Deployments to another available node cluster / cloud site | | +| Ends when | Homing is completed as per Use Case 6: NF Deployment Homing based on TE&IV services, clause 4.1.6 | | +| Exceptions | n/a | | +| Post Conditions | TE&IV Service Producer maintains an updated view of the RAN, Cloud, and relationship topology information | | +| Traceability | REQ-TE&IV -CRUDQ-FUN3, REQ-TE&IV-MODEL-FUN1, REQ-TE&IV-MODEL-FUN2, REQ-TE&IV-MODEL-FUN3, REQ-TE&IV-MODEL-FUN4, REQ-TE&IV-MODEL-FUN5, REQ-TE&IV-MODEL-FUN6 | | + +![Sequence diagram titled 'Service Management & Orchestration Framework' showing the interaction between TE&IV Service Consumer and TE&IV Service Producer for handling a cloud site outage. The diagram includes steps 1 through 9, with a loop for every RAN Logical NF Instance and an optional step for additional RAN information. A reference box points to Use case 6: NF Deployment Homing based on TE&IV services, clause 4.1.6. A final note states: 'TE&IV Service Producer maintains an updated view of the RAN, Cloud and relationship topology information'.](10a42a18a38b76dd4b996117e860e418_img.jpg) + +``` + +sequenceDiagram + participant TEIVSC as TE&IV Service Consumer + participant TEIVSP as TE&IV Service Producer + participant Framework as Service Management & Orchestration Framework + + Note left of TEIVSC: TE&IV Service Consumer (e.g. rApp) is notified with a set of alarms generated by a cloud site related to NFDeployments + + TEIVSC->>TEIVSP: 1 Query Cloud Site ID that is affected by the outage + Note right of TEIVSP: Cloud topology attributes + + TEIVSP-->>TEIVSC: 2 TE&IV Service Producer traverses through the TE&IV Cloud topology information to retrieve the associated Node clusters and NFDeployments + + TEIVSC->>TEIVSP: 3 Query the associated NF Deployments (e.g., Node cluster ids, NFDeployments ids) serving the RAN Logical NFs + Note right of TEIVSP: RAN-Cloud relationship topology attributes + + TEIVSP-->>TEIVSC: 4 TE&IV Service Producer exposes the relationship between the RAN Logical NF instances and its associated NFDeployments + + loop [For every RAN Logical NF Instance] + TEIVSC->>TEIVSP: 5 Query the Topology attributes of the RAN Logical NF instance Topology entity + Note right of TEIVSP: RAN topology attributes + + TEIVSP-->>TEIVSC: 6 TE&IV Service Producer responds with the list of Topology attributes of the RAN Logical NF instance Topology entity + end + + opt + TEIVSC->>TEIVSC: 7 TE&IV Service Consumer requests additional RAN related information from various other sources + end + + TEIVSC->>TEIVSC: 8 TE&IV Service Consumer analyzes the RAN Logical NF instances associated to the affected NFDeployments + + TEIVSC->>TEIVSC: 9 TE&IV Service Consumer performs the necessary tasks [e.g., Recommendations to a service orchestrator] to rehome the NFDeployments to another available node cluster/cloudsite + + ref + As per Use case 6: NF Deployment Homing based on TE&IV services, clause 4.1.6 + end + + Note over Framework: TE&IV Service Producer maintains an updated view of the RAN, Cloud and relationship topology information + +``` + +Sequence diagram titled 'Service Management & Orchestration Framework' showing the interaction between TE&IV Service Consumer and TE&IV Service Producer for handling a cloud site outage. The diagram includes steps 1 through 9, with a loop for every RAN Logical NF Instance and an optional step for additional RAN information. A reference box points to Use case 6: NF Deployment Homing based on TE&IV services, clause 4.1.6. A final note states: 'TE&IV Service Producer maintains an updated view of the RAN, Cloud and relationship topology information'. + +**Figure 4.1.8.3-1: Handling Cloud Site Outage Using TE&IV Services** + +#### 4.1.8.4 Required Data + +TE&IV Service Producer has information about the O-Cloud resources and the O-RAN Network Functions + +TE&IV Service Producer has information regarding the relationship between O-RAN Network Functions and its associated NF deployments in the cloud. + +# 5. Requirements + +## 5.1 Functional Requirements + +**Table 5.1-1: TE&IV services Functional Requirements** + +| REQ | Description | Notes | +|------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------| +| REQ -TE&IV-CRUDQ-FUN1 | TE&IV services shall support the creation of TE&IV resources. | Use case 4.1.1
Use case 4.1.5
Use case 4.1.7 | +| REQ- TE&IV -CRUDQ-FUN2 | TE&IV services shall support the update of TE&IV resources. | Use case 4.1.1
Use case 4.1.7 | +| REQ-TE&IV -CRUDQ-FUN3 | TE&IV services shall support the query of TE&IV resources. | Use case 4.1.1
Use case 4.1.2
Use case 4.1.4
Use case 4.1.7
Use case 4.1.8 | +| REQ -TE&IV-CRUDQ-FUN4 | TE&IV services shall support the capability of subscribing for notifications related to changes in TE&IV resources. | Use case 4.1.5
Use case 4.1.7 | +| REQ -TE&IV-CRUDQ-FUN5 | TE&IV services shall support the capability of notifying subscribers related to changes in TE&IV resources. | Use case 4.1.5
Use case 4.1.7 | +| REQ -TE&IV-CRUDQ-FUN6 | TE&IV services shall support the capability to delete TE&IV resources. | Use case 4.1.3 | +| REQ- TE&IV -BULK-FUN1 | TE&IV services shall support the bulk upload capability for creating and updating TE&IV resources. | Use case 4.1.5 | +| REQ-TE&IV-MODEL-FUN1 | TE&IV services shall have the capability to provide data about RAN resources and the relationship between them. | Use case 4.1.4
Use case 4.1.8 | +| REQ-TE&IV-MODEL-FUN2 | TE&IV services shall have the capability to provide data about NF Deployments and the relationships between them. | Use case 4.1.4
Use case 4.1.6
Use case 4.1.8 | +| REQ-TE&IV-MODEL-FUN3 | TE&IV services shall have the capability to provide data about O-Cloud resources available in the network and the relationships between them. | Use case 4.1.4
Use case 4.1.6
Use case 4.1.7
Use case 4.1.8 | +| REQ-TE&IV-MODEL-FUN4 | TE&IV services shall have the capability to provide data on the relationships between the RAN resources, NF Deployment instances and O-Cloud resources. | Use case 4.1.4
Use case 4.1.6
Use case 4.1.8 | +| REQ-TE&IV-MODEL-FUN5 | TE&IV services shall be capable of uniquely identifying different types of TE&IV resources. | Use case 4.1.4
Use case 4.1.1
Use case 4.1.5
Use case 4.1.7 | +| REQ-TE&IV-MODEL-FUN6 | TE&IV services shall have the capability to support geo-location [1] based query. | Use case 4.1.2
Use case 4.1.6
Use case 4.1.8 | +| REQ-TE&IV-MODEL-FUN7 | TE&IV services shall have the capability to provide data on the | Use case 4.1.4
Use case 4.1.1
Use case 4.1.6 | + +| | | | +|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------| +| | connectivity relationships between the TE&IV resources. | | +| REQ-TE&IV-MODEL-FUN8 | TE&IV services shall have the capability to provide data on the lifecycle state of the TE&IV resources. | Use case 4.1.4
Use case 4.1.5
Use case 4.1.7 | +| REQ-TE&IV-MODEL-FUN9 | TE&IV services shall have the capability to provide data on the state of TE&IV resources derived from configuration, fault, and performance data. | Use case 4.1.4 | +| REQ-TE&IV-MODEL-FUN10 | TE&IV services shall provide the capability to update the status of the TE&IV inventory objects based on the deployment and activation status of the O-RAN Service and RAN Nodes | Use case 4.1.1 | + +## 5.2 Non-Functional Requirements + +Void + +## 5.3 Dependencies + +**Table 5.3-1: TE&IV Dependencies** + +| SMOS | Description | Notes | +|---------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| FOCOM | TE&IV services are dependent on the FOCOM to provide a subscribe/notify pattern for O-Cloud Inventory Change Notifications. | Use Case 4.1.6
Use Case 4.1.7 | +| FOCOM | TE&IV services are dependent on FOCOM to map a TE&IV Record Identifier to an O-Cloud Resource Identifier. | Use Case 4.1.6
Use Case 4.1.7
The TE&IV Record Identifier is expected to be provided on inventory create requests and must be included in the inventory change notification to correlate the O-Cloud inventory to SMO inventory. | +| FOCOM | TE&IV services are dependent on FOCOM to support a query using an O-Cloud Resource Identifier which relates to inventory resources in the O-Cloud. | Use Case 4.1.6
Use Case 4.1.7 | +| RAN NF OAM FM | TE&IV services are dependent on RAN NF OAM FM to expose the capabilities to query and subscribe to alarm events related to NF/Cells, that TE&IV Service Producer can consume | Use Case 4.1.2
Use Case 4.1.6 | +| NFO | TE&IV services are dependent on the NFO to provide a subscribe/notify pattern for O-Cloud Inventory Change Notifications. | Use Case 4.1.3 | + +# --- Annex A (informative): + +## A.1 Inventory Object Status Values + +Throughout the life cycle of the Network provisioning use case the RAN Inventory object status in the TE&IV repository is transitioned across various values depending on the orchestration and provisioning stage of the associated network resources. The status values are updated by the TE&IV Service Consumer through the services exposed by the TE&IV Service Producer. For the Network provisioning use case following status values are considered. + +NOTE: The status values specified are intended to provide information about the different stages in the lifecycle of the inventory object. It should be noted that these values might differ in various implementations. + +| Inventory Object Status | Description | +|-------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------| +| Planned | O-RAN Service or RAN Node Inventory Object created in TE&IV Repository | +| Assigned | O-RAN Service or RAN Node Inventory Object is assigned with deployment specific parameter values in TE&IV Repository. | +| Deployed | O-RAN Service or RAN Node deployed– cloudified NF deployed, PNF is discovered and registered | +| Active | O-RAN Service /RAN Node created and provisioned in O-Cloud or PNF is registered and provisioned. The RAN Node and O-RAN Service are operational. | + +--- + +The transitioning across the above status values and corresponding actions are shown in the diagram below. + +![State transition diagram for TE&IV Inventory Object Status. The diagram shows four states: Planned, Assigned, Deployed, and Active, with transitions between them labeled with actions like Plan, Assign, Deploy, Terminate, Delete, Activate, and Deactivate.](40f048aba7868a86391ba3a55b937a2d_img.jpg) + +``` + +stateDiagram-v2 + [*] --> Planned : Plan + Planned: Planned +O-RAN Service or RAN Node Inventory Object +created in TE&IV Repository + Planned --> Assigned : Assign + Planned --> [*] : Delete + Assigned: Assigned +O-RAN Service or RAN Node Inventory Object +is assigned with deployment specific parameter values in +TE&IV Repository + Assigned --> Deployed : Deploy + Deployed --> Assigned : Terminate + Assigned --> [*] : Delete + Deployed: Deployed +O-RAN Service or RAN Node deployed +cloudified NF deployed, PNF is discovered and registered + Deployed --> Active : Activate + Active --> Deployed : Deactivate + Active: Active +O-RAN Service created and provisioned, +cloudified NF deployed and activated in O-Cloud, +PNF is registered and provisioned. +The RAN Nodes and O-RAN Service are operational. + +``` + +The diagram illustrates the lifecycle of a TE&IV Inventory Object through four states: + +- Planned:** O-RAN Service or RAN Node Inventory Object created in TE&IV Repository. Reached via **Plan** from the start state. +- Assigned:** O-RAN Service or RAN Node Inventory Object is assigned with deployment specific parameter values in TE&IV Repository. Reached via **Assign** from Planned. Can transition back to Planned via **Delete**. +- Deployed:** O-RAN Service or RAN Node deployed, cloudified NF deployed, PNF is discovered and registered. Reached via **Deploy** from Assigned. Can transition back to Assigned via **Terminate**. +- Active:** O-RAN Service created and provisioned, cloudified NF deployed and activated in O-Cloud, PNF is registered and provisioned. The RAN Nodes and O-RAN Service are operational. Reached via **Activate** from Deployed. Can transition back to Deployed via **Deactivate**. + +Transitions from any state to the end state (represented by a bullseye) are labeled **Delete**. + +State transition diagram for TE&IV Inventory Object Status. The diagram shows four states: Planned, Assigned, Deployed, and Active, with transitions between them labeled with actions like Plan, Assign, Deploy, Terminate, Delete, Activate, and Deactivate. + +**Figure A.1-1: TE&IV Inventory Object Status Transition** + +## Change History + +| Date | Revision | Description | +|------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.03.09 | 01.00 | Incorporate approved CRs : ERI-2022.09.22-WG10-ERI-021-Terminology-v03 , NEC-2022-09-10-.WG10-CR-0001-Inventory_ORAN_provisioning_usecase_v06, NEC-2022-12-08-.WG10-CR-0002-Inventory_ORAN_Network_Planning_usecase_v08, NEC-2023-01-26-.WG10-CR-0003-Inventory_Functional_Requirements_v02 ,NEC-2023-02-09-.WG10-CR-0003-ORAN_TAI_Scope_v01, NEC-2023-02-23-.WG10-CR-0005-ORAN_Inventory_EN_Resolution_v03 , NEC-2023-02-28-.WG10-CR-0006-ORAN_Inventory_EN_Resolution_2_v02, ERI-2023.03.03-WG10-ERI-029-Functional-Requirement-v03, ERI-2023.01.27-WG10-CR-027-use-case-Topology-based-alarm-correlation-v04, ERI-2023.02.15-WG10-CR-028-use-case-R1 Alarm query using TE&IV Services-v04 | +| 2023.03.13 | 01.00 | Address comments from WG10 review | +| 2023.05.04 | 01.00.01 | Implemented approved CRs for July train: ERI-2023.03.16-WG10-CR-030-use-case-NF_Deployment_Homing_v06, NEC-2023-03-30-WG10-CR-0007-Inventory_Functional_Requirements_v03, NEC-2023-04-13-WG10-CR-0008-Inventory_ORAN_NF_Termination_usecase_v01 | +| 2023.05.11 | 01.00.02 | Updated Table of Contents, Included CR version | +| 2023.07.05 | 01.00.03 | Implemented approved CRs for July train: NEC-2023-05-18-WG10-CR-0009-Inventory_Resolve_EN_v01, ERI-2023.05.09-WG10-CR-034-use-case-O-Cloud_Provisioning-v04, alignment with ERI-2023.03.16-WG10-CR-030-use-case-NF_Deployment_Homing_v06, NEC-2023-06-14-.WG10-CR-0010-ORAN_Usecase_Required_Data_v2, NEC-2023-03-30-WG10-CR-0007-Inventory_Functional_Requirements_v04, NEC-2023-05-18-WG10-CR-0009-Inventory_Resolve_EN_v02, ERI-2023.07.12-WG10-CR-037-Editorial_updates-v01 | +| 2023.07.05 | 01.00.04 | Updated as per review comments received in WG10 TE&IV review page (Editorial) | +| 2023.10.10 | 01.00.05 | Implemented approved CRs for November train: ATT-2023.08.30-WG10-CR-014-O-Cloud Provisioning Update-v05, ERI-2023.10.02-WG10-CR-039-use-case-Updates to R1 Alarm query using TE&IV Services-v02, ERI-2023.10.02-WG10-CR-040-use-case-Updates-to-NF-Deployment-Homing-v02, ERI-2023.10.02-WG10-CR-040-use-case-Updates to Topology based Alarm Correlation-v01, NEC-2023-09-14-WG10-CR-0011-NW_Provisioning_NW_Planning_Revision_v06, ERI-2023.10.10-WG10-CR-046-Editorial_Updates_to_TE&IV_UCR_v01 | +| 2023.11.01 | 02.00 | Implemented approved CR for November train: NEC-2023-10-12-.WG10-CR-0012-Terminate_NF_NW_PlanningRevision_v03 | +| 2024.07.12 | 03.00 | Implemented approved CR for July train: ERI-2024.06.06-WG10-CR-0088-Cloudsite-Outage-Use-Case-v02, Editorial corrections. | +| 2024.07.15 | 03.00 | Addressed WG10 review comments. Used Atlassian versioning to track revisions on the captured comments. | \ No newline at end of file diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/05eb3369301d418dcb82876643e3db9f_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/05eb3369301d418dcb82876643e3db9f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7429cee58f6b43bf97b2e7ad3fe464ee11aaefc7 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/05eb3369301d418dcb82876643e3db9f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15547aceb1e524165623668b58b2c28cd3e14dc6c6309b856741316a94e85300 +size 4494 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2fd5eaeff22262dc085e14adfdb0ad2472ac9dc2 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd2727019ae96e80efda4964e1a871737c2c73277a978726969f55d0e5275c2f +size 4536 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/168291deebfcd76051dcee428ed897d3_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/168291deebfcd76051dcee428ed897d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d294275f7833967ae08c35d4c3fd393f1bb6109b --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/168291deebfcd76051dcee428ed897d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:338ed8342f32201bfa7b83e9dd53f8604a2829d1f94acda1448ff380ab5a5aae +size 11370 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/2bdb41b2759aa5248b4e6f7cfbd32506_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/2bdb41b2759aa5248b4e6f7cfbd32506_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..10c6796b9e26e1dbdc8d66afcaf6dc6dc63c1204 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/2bdb41b2759aa5248b4e6f7cfbd32506_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ae9bf36b3af77e0346974930d217b15ec7018042af0e69c6859c7ecf4a2bc636 +size 12696 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/2e5202121732aea00ebefab6956b017b_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/2e5202121732aea00ebefab6956b017b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a36945a9ba27cef3dc9e956f8059b0ccfc8c4f1e --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/2e5202121732aea00ebefab6956b017b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9200b5e6f30e50a895870fbd8d1e192eb06d5efbe1566aba9ce948825a86ebe6 +size 128425 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/4484ba4432bd5c53d4be62b41ceac2c9_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/4484ba4432bd5c53d4be62b41ceac2c9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3ae22477048ae33d5a1909e2283a4f88688d277f --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/4484ba4432bd5c53d4be62b41ceac2c9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:27419fe0f4f0af35229120c5fdfe87e0c5f849c7041e7db6b800e4d130e4ce52 +size 44456 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/56e9028167837aff1a14235a7816fda1_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/56e9028167837aff1a14235a7816fda1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d3c354afdbfb5502a1aad5ad5c2d674412d8b5cc --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/56e9028167837aff1a14235a7816fda1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:447b7c5123b3929fcf5c85b90f7c12b846f67d4138d44cffa0780d9eb316773c +size 12526 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/9c0184f365e9c98ce135195bc3f1ef37_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/9c0184f365e9c98ce135195bc3f1ef37_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..77ed111865ab35422971de61d74dea12c5b8c12a --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/9c0184f365e9c98ce135195bc3f1ef37_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b86e2793ca99b94b4f63ddfda93455190e7e140c7ce8cc545b00c9d69aa005a6 +size 14713 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/9e02ddd0aa0383dbcd91f3b6aa1e04f5_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/9e02ddd0aa0383dbcd91f3b6aa1e04f5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ee95bacf92bcc9341f1e4ff2a2f92e64db3de0f3 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/9e02ddd0aa0383dbcd91f3b6aa1e04f5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:009ef0c39e6bb8ae40c8e9f3b9d9415479a8476ce2b84ce82d31a456ee76fa0b +size 14068 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/c1bc15cc1c93c930f668b9979c99952d_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/c1bc15cc1c93c930f668b9979c99952d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b9fdb5d4483155dcf5045b4adb409a04e1e24730 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/c1bc15cc1c93c930f668b9979c99952d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1a36d92dd3cdb88dfc7aeb1c462abd13de46f3cbf405724339367dcc72700366 +size 4566 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f9786619d9266ddf6962b7631fad8834bd583a3 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:17a48c732b82959a70a4744afdf56099b05c77a70dfcfaa935549c6ab678bec2 +size 4509 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/d90084c8ee22bf5fc20267d1044db808_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/d90084c8ee22bf5fc20267d1044db808_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f5ed80ad4cebdcbf8150aef8c1489c145ae480d6 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/d90084c8ee22bf5fc20267d1044db808_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:73379f82d12715f27bfd5c2136c165a7ce1e5bcac6de2b502196d89f3f2e360f +size 20177 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/f679f810fad1a731a30846bcc8a81740_img.jpg b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/f679f810fad1a731a30846bcc8a81740_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..da98f446f00025b18df55a99812d84ddc573edfa --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/f679f810fad1a731a30846bcc8a81740_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0d8c96a21125dff9fe96c32bb6ff384c015930b9338ec1bc86fd22101ef2a8b2 +size 11921 diff --git a/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/raw.md b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..77eae53f1cf240be7c08f0de567c13f080099ac8 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00/raw.md @@ -0,0 +1,690 @@ + + +# --- **O-RAN Work Group 10 (OAM for O-RAN)** + +## **O1 Network Resource Model** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|-------------------------------------------------------------|-----------| +| Foreword..... | 3 | +| Modal verbs terminology..... | 3 | +| 1 Scope ..... | 3 | +| 2 References ..... | 3 | +| 2.1 Normative references ..... | 3 | +| 2.2 Informative references..... | 4 | +| 3 Definition of terms, symbols and abbreviations..... | 5 | +| 3.1 Terms..... | 5 | +| 3.2 Symbols..... | 5 | +| 3.3 Abbreviations ..... | 5 | +| 4 Requirements..... | 5 | +| 4.1 General Requirements ..... | 5 | +| 5 Model ..... | 6 | +| 5.1 Imported and associated information entities ..... | 6 | +| 5.1.1 Imported information entities and local labels..... | 6 | +| 5.1.2 Associated information entities and local labels..... | 6 | +| 5.2 Class diagrams..... | 6 | +| 5.2.1 Relationships..... | 6 | +| 5.2.2 Inheritance ..... | 8 | +| 5.3 Class definitions ..... | 10 | +| 5.3.1 ManagedApplication..... | 10 | +| 5.3.2 NearRTRICFunction..... | 11 | +| 5.3.3 EP_E2 ..... | 11 | +| 5.3.4 EP_A1..... | 12 | +| 5.3.5 NESPolicy..... | 12 | +| 5.3.6 NESPolicyRelation ..... | 13 | +| 5.3.7 RRMPolicyRBAalloc ..... | 14 | +| 5.4 Attribute definitions ..... | 15 | +| 5.4.1 Attribute properties ..... | 15 | +| 5.5 Common notifications ..... | 19 | +| 5.5.1 Alarm notifications ..... | 19 | +| 5.5.2 Configuration notifications ..... | 19 | +| Annex (informative): Change History ..... | 21 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG10 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the Information Model and the Data Model for Network Resource Model (NRM) that are foundational for functions carried out over the O-RAN O1 interface. + +The O-RAN Information Model follows the methodology documented in 3GPP TS 32.160 [1] Clause 5.2. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] 3GPP TS 32.160: “Management and orchestration; Management service template” +- [2] 3GPP TS 32.156: “Telecommunication management; Fixed Mobile Convergence (FMC); model repertoire” +- [3] 3GPP TS 28.622: "Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS)", 3GPP, v18.8.0, 2024-09 +- [4] 3GPP TS 28.625: "Telecommunication management; State Management data definition Integration Reference Point (IRP); Information Service (IS)" +- [5] O-RAN.WG3.E2AP: "Near-Real-time RAN Intelligent Controller and E2 Interface -E2 Application Protocol (E2AP)" +- [6] O-RAN.WG3.RICARCH: "O-RAN Work Group 3 (Near-Real-time RAN Intelligent Controller and E2 Interface) Near-RT RIC Architecture" +- [7] 3GPP TS 28.658: "Telecommunication management; Evolved Universal Terrestrial Radio Access Network (E-UTRAN); Network Resource Model (NRM); Integration Reference Point (IRP); Information Service (IS)" +- [8] ITU-T Recommendation X.731: "Information technology - Open Systems Interconnection - Systems Management: State management function" +- [9] O-RAN.WG1.OAD: "O-RAN Architecture Description" +- [10] 3GPP TS 28.532: “Management and orchestration; Generic management services” +- [11] O-RAN TS: “O-RAN O1 Interface Specification” +- [12] 3GPP TS 28.541: “Management and orchestration; 5G Network Resource Model (NRM) ; Stage 2 and stage 3” +- [13] ORAN-WG4.CUS.0-v15.00 “Control, User and Synchronization Plane Specification”, O-RAN Alliance, Working Group 4 +- [14] 3GPP TS 38.211: NR; Physical channels and modulation +- [15] Semantic Versioning Specification 2.0.0: +- [16] 3GPP TS 28.111: “Management and orchestration; Fault Management (FM)” + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: Vocabulary for 3GPP Specifications + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in [i.1] and the following apply: + +**Information Model:** a representation of concepts and the relationships, constraints, rules, and operations to specify data semantics for a chosen domain of discourse, it specifies relations between objects, can provide sharable, stable, and organized structure of information requirements or knowledge for the domain context. + +**Data Model:** an abstract model that organizes elements of data and standardizes how they relate to one another and to the properties of real-world entities. The term data model may refer to two distinct but closely related concepts: (1) an abstract formalization of the objects and relationships found in a particular application domain; (2) the set of concepts used in defining such formalizations - for example concepts such as entities, attributes, relations, or tables. + +## 3.2 Symbols + +For the purposes of the present document, the symbols given in [i.1] apply: + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in [i.1] and the following apply: + +| | | +|-------|---------------------------| +| BS | Base Station | +| CRB | Common Resource Block | +| DN | Distinguished Name | +| IOC | Information Object Class | +| MnS | Management Service | +| MOI | Managed Object Instance | +| NES | Network Energy Saving | +| NRM | Network Resource Model | +| O-DU | O-RAN Distributed Unit | +| O-RAN | Open Radio Access Network | +| O-RU | O-RAN Radio Unit | + +# --- 4 Requirements + +## 4.1 General Requirements + +The following general requirements apply: + +Table 4.1-1: General Requirements + +| Requirement label | Description | Motivation | +|---------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------| +| REQ-NRM-MC-1 | O1 NRM stage 2 shall follow the templates described in clause 5.2 of 3GPP TS 32.160 [1], using the applicable fonts defined in Table 5.1.1-1 of 3GPP TS 32.160 [1]. | Identify the templates and fonts to be used for the definition of O1 network resource model | +| REQ-NRM-MC-2 | The O1 NRM stage 2 shall follow the model repertoire documented in 3GPP TS 32.156 [2] | Identify common set of UML notations to model network resources | + +# 5 Model + +## 5.1 Imported and associated information entities + +### 5.1.1 Imported information entities and local labels + +Table 5.1.1-1: Imported information entities and local labels + +| Label reference | Local label | +|-------------------------------------------------------------|------------------------------| +| 3GPP TS 28.622 [3], IOC, Top | Top | +| 3GPP TS 28.625 [4], Archetype, StateManagementEntity | StateManagementEntity | +| 3GPP TS 28.622 [3], IOC, ManagedFunction | ManagedFunction | +| 3GPP TS 28.622 [3], IOC, EP_RP | EP_RP | +| 3GPP TS 28.658 [7], datatype, PLMNId | PLMNId | +| 3GPP TS 28.622 [3], dataType, TimeWindow | TimeWindow | +| 3GPP TS 28.541 [12], dataType, RRMPolicyMember | RRMPolicyMember | + +### 5.1.2 Associated information entities and local labels + +Table 5.1.2-1: Associated information entities and local labels + +| Label reference | Local label | +|------------------------------------------------|-----------------------| +| 3GPP TS 28.622 [3], IOC, ManagedElement | ManagedElement | +| 3GPP TS 28.541 [12], IOC, GNBDUFunction | GNBDUFunction | +| 3GPP TS 28.541 [12], IOC, NRCe11DU | NRCe11DU | + +## 5.2 Class diagrams + +### 5.2.1 Relationships + +This clause depicts the set of classes (e.g. IOCs) that encapsulates the information relevant for this MnS. This clause provides an overview of the relationships between relevant classes in UML. Subsequent clauses provide more detailed specification of various aspects of these classes. + +![UML Class Diagram for NRM entities: ManagedElement, NearRTRICFunction, ManagedApplication, EP_A1, Non-RT RIC, EP_E2, and E2 Node.](2e5202121732aea00ebefab6956b017b_img.jpg) + +``` + +classDiagram + class ManagedElement["«InformationObjectClass» ManagedElement"] + class NearRTRICFunction["«InformationObjectClass» NearRTRICFunction"] + class ManagedApplication["«InformationObjectClass» ManagedApplication"] + class EP_A1["«InformationObjectClass» EP_A1"] + class Non_RT_RIC["«SupportIOC» Non-RT RIC"] + class EP_E2["«InformationObjectClass» EP_E2"] + class E2_Node["«proxyClass» E2 Node"] + + ManagedElement "1" -- "*" NearRTRICFunction : «names» + ManagedElement "1" -- "*" ManagedApplication : «names» + NearRTRICFunction "1" -- "1" ManagedApplication : +hostDN + NearRTRICFunction "1" -- "*" ManagedApplication : +applicationDNList + NearRTRICFunction "1" -- "0..1" EP_A1 : «names» + EP_A1 "*" -- "0..1" Non_RT_RIC + EP_E2 "*" -- "1" E2_Node : +farEndEntity + E2_Node "1" -- "0..1" EP_E2 : «names» + EP_E2 "*" -- "1" NearRTRICFunction : +farEndEntity + + note for E2_Node "Proxy class representing any of the following E2 EndPoints: O-CU-CP, O-CU-UP, O-DU, O-eNB" + note for NearRTRICFunction "Proxy class representing any of the following E2 EndPoints: O-CU-CP, O-CU-UP, O-DU, O-eNB" + +``` + +The diagram illustrates the relationships between several entities in the NRM (Network Resource Management) framework. The entities are represented as classes, with some being «InformationObjectClass» and others being «proxyClass» or «SupportIOC». + +- ManagedElement** («InformationObjectClass») is associated with **NearRTRICFunction** («InformationObjectClass») and **ManagedApplication** («InformationObjectClass») via «names» relationships. ManagedElement has a cardinality of 1, while NearRTRICFunction and ManagedApplication have a cardinality of \*. +- NearRTRICFunction** («InformationObjectClass») is associated with **ManagedApplication** («InformationObjectClass») via two relationships: one with cardinality 1 to 1 labeled +hostDN, and another with cardinality 1 to \* labeled +applicationDNList. +- NearRTRICFunction** («InformationObjectClass») is associated with **EP\_A1** («InformationObjectClass») via a «names» relationship with cardinality 1 to 0..1. +- EP\_A1** («InformationObjectClass») is associated with **Non-RT RIC** («SupportIOC») with a cardinality of \* to 0..1. +- EP\_E2** («InformationObjectClass») is associated with **E2 Node** («proxyClass») via a +farEndEntity relationship with cardinality \* to 1. +- E2 Node** («proxyClass») is associated with **EP\_E2** («InformationObjectClass») via a «names» relationship with cardinality 1 to 0..1. +- EP\_E2** («InformationObjectClass») is associated with **NearRTRICFunction** («InformationObjectClass») via a +farEndEntity relationship with cardinality \* to 1. + +Two proxy classes are defined for E2 EndPoints: + +- E2 Node** («proxyClass») is a proxy class representing any of the following E2 EndPoints: O-CU-CP, O-CU-UP, O-DU, O-eNB. +- NearRTRICFunction** («InformationObjectClass») is a proxy class representing any of the following E2 EndPoints: O-CU-CP, O-CU-UP, O-DU, O-eNB. + +UML Class Diagram for NRM entities: ManagedElement, NearRTRICFunction, ManagedApplication, EP\_A1, Non-RT RIC, EP\_E2, and E2 Node. + +Figure 5.2.1-1: NRM for ManagedApplication and NearRTRICFunction related entities + +![UML class diagram showing Network energy saving NRM fragment. It includes classes GNBDUFunction, NRCellIDU, NESPolicyRelation, and NESPolicy with their relationships and multiplicities.](4484ba4432bd5c53d4be62b41ceac2c9_img.jpg) + +``` + +classDiagram + class GNBDUFunction["«InformationObjectClass»\nGNBDUFunction"] + class NRCellIDU["«InformationObjectClass»\nNRCellIDU"] + class NESPolicyRelation["«InformationObjectClass»\nNESPolicyRelation"] + class NESPolicy["«InformationObjectClass»\nNESPolicy"] + + GNBDUFunction "1" *-- "*" NRCellIDU : «names» + NRCellIDU "1" *-- "0..1" NESPolicyRelation : «names» + NESPolicyRelation "*" --> "*" NESPolicy : +configuredNesPolicyList 1..* + GNBDUFunction "*" --> "*" NESPolicy : «names» + +``` + +UML class diagram showing Network energy saving NRM fragment. It includes classes GNBDUFunction, NRCellIDU, NESPolicyRelation, and NESPolicy with their relationships and multiplicities. + +Figure 5.2.1-2: Network energy saving NRM fragment. + +![UML class diagram showing RRM Policy RB Allocation containment. It includes classes NRCellIDU and RRMPolicyRBAlloc with their relationship and multiplicities.](9e02ddd0aa0383dbcd91f3b6aa1e04f5_img.jpg) + +``` + +classDiagram + class NRCellIDU["«InformationObjectClass»\nNRCellIDU"] + class RRMPolicyRBAlloc["«InformationObjectClass»\nRRMPolicyRBAlloc"] + + NRCellIDU "1" *-- "0..*" RRMPolicyRBAlloc : «names» + +``` + +UML class diagram showing RRM Policy RB Allocation containment. It includes classes NRCellIDU and RRMPolicyRBAlloc with their relationship and multiplicities. + +Figure 5.2.1-3: RRM Policy RB Allocation containment + +### 5.2.2 Inheritance + +This subclause depicts the inheritance relationships. + +![UML class diagram showing ManagedApplication inheritance. It includes classes Top and ManagedApplication with an inheritance relationship.](56e9028167837aff1a14235a7816fda1_img.jpg) + +``` + +classDiagram + class Top["«InformationObjectClass»\nTop"] + class ManagedApplication["«InformationObjectClass»\nManagedApplication"] + + ManagedApplication --|> Top + +``` + +UML class diagram showing ManagedApplication inheritance. It includes classes Top and ManagedApplication with an inheritance relationship. + +Figure 5.2.2-1: ManagedApplication inheritance + +![UML class diagram showing inheritance from ManagedFunction to NearRTRICFunction.](9c0184f365e9c98ce135195bc3f1ef37_img.jpg) + +``` + +classDiagram + class ManagedFunction["«InformationObjectClass» ManagedFunction"] + class NearRTRICFunction["«InformationObjectClass» NearRTRICFunction"] + ManagedFunction <|-- NearRTRICFunction + +``` + +A UML class diagram showing inheritance. The superclass is «InformationObjectClass» ManagedFunction. The subclass is «InformationObjectClass» NearRTRICFunction. A solid line with an open triangle arrow points from the subclass to the superclass. + +UML class diagram showing inheritance from ManagedFunction to NearRTRICFunction. + +Figure 5.2.2-2: NearRTRICFunction inheritance + +![UML class diagram showing inheritance from EP_RP to EP_E2.](f679f810fad1a731a30846bcc8a81740_img.jpg) + +``` + +classDiagram + class EP_RP["«InformationObjectClass» EP_RP"] + class EP_E2["«InformationObjectClass» EP_E2"] + EP_RP <|-- EP_E2 + +``` + +A UML class diagram showing inheritance. The superclass is «InformationObjectClass» EP\_RP. The subclass is «InformationObjectClass» EP\_E2. A solid line with an open triangle arrow points from the subclass to the superclass. + +UML class diagram showing inheritance from EP\_RP to EP\_E2. + +Figure 5.2.2-3: EP\_E2 inheritance + +![UML class diagram showing inheritance from EP_RP to EP_A1.](168291deebfcd76051dcee428ed897d3_img.jpg) + +``` + +classDiagram + class EP_RP["«InformationObjectClass» EP_RP"] + class EP_A1["«InformationObjectClass» EP_A1"] + EP_RP <|-- EP_A1 + +``` + +A UML class diagram showing inheritance. The superclass is «InformationObjectClass» EP\_RP. The subclass is «InformationObjectClass» EP\_A1. A solid line with an open triangle arrow points from the subclass to the superclass. + +UML class diagram showing inheritance from EP\_RP to EP\_A1. + +Figure 5.2.2-4: EP\_A1 inheritance + +![UML class diagram showing inheritance from Top to NESPolicy and NESPolicyRelation.](d90084c8ee22bf5fc20267d1044db808_img.jpg) + +``` + +classDiagram + class Top["«InformationObjectClass» Top"] + class NESPolicy["«InformationObjectClass» NESPolicy"] + class NESPolicyRelation["«InformationObjectClass» NESPolicyRelation"] + Top <|-- NESPolicy + Top <|-- NESPolicyRelation + +``` + +A UML class diagram showing inheritance. The superclass is «InformationObjectClass» Top. There are two subclasses: «InformationObjectClass» NESPolicy and «InformationObjectClass» NESPolicyRelation. Solid lines with open triangle arrows point from both subclasses to the superclass. + +UML class diagram showing inheritance from Top to NESPolicy and NESPolicyRelation. + +Figure 5.2.2-5: Network energy saving NRM inheritance. + +![UML class diagram showing inheritance. A yellow box labeled '«InformationObjectClass» Top' is at the top. A red arrow with an open triangle head points from a yellow box labeled '«InformationObjectClass» RRMPolicyRBAlloc' below it to the 'Top' box.](2bdb41b2759aa5248b4e6f7cfbd32506_img.jpg) + +``` + +classDiagram + class Top["«InformationObjectClass»\nTop"] + class RRMPolicyRBAlloc["«InformationObjectClass»\nRRMPolicyRBAlloc"] + Top <|-- RRMPolicyRBAlloc + +``` + +UML class diagram showing inheritance. A yellow box labeled '«InformationObjectClass» Top' is at the top. A red arrow with an open triangle head points from a yellow box labeled '«InformationObjectClass» RRMPolicyRBAlloc' below it to the 'Top' box. + +Figure 5.2.2-6: RRM Policy RB Allocation inheritance + +## 5.3 Class definitions + +### 5.3.1 ManagedApplication + +#### 5.3.1.1 Definition + +The *ManagedApplication* IOC defines attribute(s) that are common to application IOCs. This IOC represents a deployed instance of software application that may be independently tested and separately deployed from the hosting entity. + +#### 5.3.1.2 Attributes + +The *ManagedApplication* IOC includes the inherited from *Top* IOC (defined in 3GPP TS 28.622 [3], clause 4.3.29), attributes *operationalState*, *usageState*, *administrativeState* imported from *StateManagementEntity* Archetype (defined in 3GPP TS 28.625 [4], clause 4.3.1) and the following attributes: + +Table 5.3.1.2-1: ManagedApplication attributes + +| Attribute name | S | isReadable | isWritable | isInvariant | isNotifiable | +|----------------------------------|---|------------|------------|-------------|--------------| +| applicationVersion | M | T | F | F | T | +| applicationName | M | T | F | T | T | +| userLabel | O | T | T | F | T | +| operationalState | M | T | F | F | T | +| usageState | M | T | F | F | T | +| administrativeState | M | T | T | F | T | +| Attribute related to role | | | | | | +| hostDN | M | T | F | T | T | + +#### 5.3.1.3 Attribute constraints + +None + +#### 5.3.1.4 Notifications + +The common notifications defined in clause 5.5 are valid for this class, without exceptions or additions. + +#### 5.3.1.5 State diagram + +None + +### 5.3.2 NearRTRICFunction + +#### 5.3.2.1 Definition + +The *NearRTRICFunction* IOC represents the Management aspects of the aggregated functions making up the Near-RT RIC (defined in O-RAN Architecture Description [9], clause 5.3.2). + +#### 5.3.2.2 Attributes + +The *NearRTRICFunction* IOC includes the attributes below and those attributes inherited through *ManagedFunction* IOC (defined in 3GPP TS 28.622 [3]). + +**Table 5.3.2.2-1: NearRTRIC attributes** + +| Attribute Name | S | isReadable | isWritable | isInvariant | isNotifiable | +|----------------------------------|---|------------|------------|-------------|--------------| +| pLMNIdentity | M | T | T | F | T | +| nearRTRICID | M | T | T | F | T | +| Attribute related to role | | | | | | +| applicationDNList | M | T | F | F | T | + +#### 5.3.2.3 Attribute constraints + +None + +#### 5.3.2.4 Notifications + +The common notifications defined in clause 5.5 are valid for this class, without exceptions or additions. + +#### 5.3.2.5 State diagram + +None + +### 5.3.3 EP\_E2 + +#### 5.3.3.1 Definition + +The *EP\_E2* IOC represents the management aspects of the E2 Termination (defined in O-RAN Near-RT RIC Architecture [6] clause 6.2.7.1). + +#### 5.3.3.2 Attributes + +The *EP\_E2* IOC includes the attributes below and those attributes inherited through *EP\_RP* IOC (defined in 3GPP TS 28.622 [3]). + +**Table 5.3.3.2-1: EP\_E2 attributes** + +| Attribute Name | S | isReadable | isWritable | isInvariant | isNotifiable | +|-----------------|---|------------|------------|-------------|--------------| +| tRICEventCreate | O | T | T | F | T | +| tRICEventDelete | O | T | T | F | T | +| tRICControl | O | T | T | F | T | +| tRICEventModify | O | T | T | F | T | +| tRICQuery | O | T | T | F | T | + +#### 5.3.3.3 Attribute constraints + +None + +#### 5.3.3.4 Notifications + +The common notifications defined in clause 5.5 are valid for this class, without exceptions or additions. + +#### 5.3.3.5 State diagram + +None + +### 5.3.4 EP\_A1 + +#### 5.3.4.1 Definition + +The `EP_A1` IOC represents the management aspects of the A1 Termination (defined in O-RAN Near-RT RIC Architecture [6] clause 6.2.7.2). + +#### 5.3.4.2 Attributes + +The `EP_A1` IOC includes the attributes inherited through `EP_RP` IOC (defined in 3GPP TS 28.622 [3]). + +#### 5.3.4.3 Attribute constraints + +None + +#### 5.3.4.4 Notifications + +The common notifications defined in clause 5.5 are valid for this class, without exceptions or additions. + +#### 5.3.4.5 State diagram + +None + +### 5.3.5 NESPolicy + +#### 5.3.5.1 Definition + +The `NESPolicy` IOC represents the policy for network energy saving (NES) for the NR Cell(s) managed by the O-DU. + +When the NES Policy is created or updated by receiving a NES policy file, the `NESPolicy` MOI shall be created by MnS producer (O-DU) when it successfully receives NES policy file. The attribute `policyId` represents the unique identifier of the policy, corresponding to the policy file. The NES policy is applicable for the energy saving in the downlink. + +An NES policy can be associated with none, one or more NR Cell(s) (i.e., `NRCe11DU`) of the O-DU. When an NES policy is associated to none of NR Cell(s) (i.e., the DN of the `NESPolicy` MOI is not referenced in attribute `configuredNesPolicyList` of any `NESPolicyRelation` MOIs), the O-DU shall not consider the policy for evaluation. + +The `NESPolicy` MOI corresponding to NES policy related to TRx Control (RF Channel Reconfiguration) based energy saving contains attribute `policyType` with value `TRX_CONTROL`. The attributes `antennaMask` and `sleepMode` provide the values from the NES policy file for the TRx control based energy saving. + +The `NESPolicy` MOI corresponding to NES policy related to advanced sleep mode based energy saving contains attribute `policyType` with value `ASM`. The attribute `sleepMode` provides the value from the NES policy file for the advanced sleep mode based energy saving. + +The MnS consumer shall be able to configure the time window(s) when this NES policy is applicable, using the attribute `applicableTimeWindows` of corresponding `NESPolicy` MOI. Multiple time windows can be configured for the policy using the attribute `applicableTimeWindows`. If the `applicableTimeWindows` is not present or if the `startTime` and `endTime` of any element of the list attribute `applicableTimeWindows` are configured with the same values, then O-DU shall not use the time condition for the policy, i.e., the policy is applicable without time condition. Setting overlapping time windows in the same `NESPolicy` MOI may cause undefined behavior. + +#### 5.3.5.2 Attributes + +The `NESPolicy` IOC includes attributes inherited from `Top` IOC (defined in 3GPP TS 28.622 [3], clause 4.3.29) and the following attributes: + +**Table 5.3.5.2-1: NESPolicy attributes** + +| Attribute name | S | isReadable | isWritable | isInvariant | isNotifiable | +|------------------------------------|---|------------|------------|-------------|--------------| +| policyId | M | T | F | T | F | +| policyType | M | T | F | T | F | +| applicableTimeWindows | O | T | T | F | T | +| sleepMode | O | T | F | T | F | +| antennaMask | O | T | F | T | F | + +#### 5.3.5.3 Attributes constraints + +None + +#### 5.3.5.4 Notifications + +The common notifications defined in clause 5.5 are valid for this class, without exceptions or additions. + +#### 5.3.5.5 State diagram + +None + +### 5.3.6 NESPolicyRelation + +#### 5.3.6.1 Definition + +The `NESPolicyRelation` IOC represents the NES policies configured for the NR Cell. `NESPolicyRelation` MOI with attribute `configuredNesPolicyList` with an empty list is invalid. + +#### 5.3.6.2 Attributes + +The NESPolicyRelation IOC includes attributes inherited from *Top* IOC (defined in 3GPP TS 28.622 [3], clause 4.3.29) and the following attributes: + +**Table 5.3.6.2-1: NESPolicyRelation attributes** + +| Attribute name | S | isReadable | isWritable | isInvariant | isNotifyable | +|---------------------------|---|------------|------------|-------------|--------------| +| Attribute related to role | | | | | | +| configuredNesPolicyList | M | T | T | F | T | + +#### 5.3.6.3 Attributes constraints + +None + +#### 5.3.6.4 Notifications + +The common notifications defined in clause 5.5 are valid for this class, without exceptions or additions. + +#### 5.3.6.5 State diagram + +None + +### 5.3.7 RRMPolicyRBAlloc + +#### 5.3.7.1 Definition + +The RRMPolicyRBAlloc IOC provides the necessary attributes to set the resource segment defined as the combination of starting position of common resource block (CRB) allocation and number of physical resource blocks within the available frequency resource for each cell. + +#### 5.3.7.2 Attributes + +The RRMPolicyRBAlloc IOC includes attributes inherited from *Top* IOC (defined in 3GPP TS 28.622 [3], clause 4.3.29) and contains the following attributes: + +**Table 5.3.7.2-1: RRMPolicyRBAlloc attributes** + +| Attribute name | S | isReadable | isWritable | isInvariant | isNotifyable | +|---------------------|---|------------|------------|-------------|--------------| +| direction | M | T | T | F | T | +| rRMPolicyMemberList | M | T | T | F | T | +| startCellRBAlloc | M | T | T | F | T | +| numberOfPRBs | O | T | T | F | T | + +#### 5.3.7.3 Attribute constraints + +None + +#### 5.3.7.4 Notifications + +The common notifications defined in clause 5.5 are valid for this class, without exceptions or additions. + +#### 5.3.7.5 State diagram + +None + +## 5.4 Attribute definitions + +### 5.4.1 Attribute properties + +The following table defines the properties of attributes that are specified in the present document. + +Table 5.4.1-1: Attribute definitions + +| Attribute Name | Documentation and Allowed Values | Properties | +|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------| +| applicationVersion |

This attribute contains the application version numbers that shall consist of at least 3 fields, following a MAJOR.MINOR.PATCH pattern according to the Semantic Versioning Specification [15].

allowedValues: Not applicable.

|

type: String
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: False

| +| applicationName |

This attribute contains the name of the application.

allowedValues: Not applicable.

|

type: String
multiplicity: 0..1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: True

| +| userLabel |

This attribute contains user defined label for the application

allowedValues: Not applicable.

|

type: String
multiplicity: 0..1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: True

| +| operationalState |

It indicates the operational state of the object instance. "It describes whether or not the resource is physically installed and working." This attribute is READ-ONLY. The meaning of these values is as defined in ITU-T Recommendation X.731 [8].

allowedValues: "ENABLED", "DISABLED"

|

type: ENUM
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: False

| +| usageState |

It indicates the usage state of the object instance. "It describes whether or not the resource is actively in use at a specific instant, and if so, whether or not it has spare capacity for additional users at that instant." This attribute is READ-ONLY. The meaning of these values is as defined in ITU-T Recommendation X.731 [8].

allowedValues: "IDLE", "ACTIVE", "BUSY"

|

type: ENUM
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: False

| +| administrativeState |

It indicates the administrative state of the object instance. "It describes the permission to use or prohibition against using the resource, imposed through the management services." The meaning of these values is as defined in ITU-T Recommendation X.731 [8].

allowedValues: "LOCKED", "SHUTTINGDOWN", "UNLOCKED".

|

type: ENUM
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: False

| +| tRICEventCreate |

Near-RT RIC attribute defined in O-RAN.WG3.E2AP [5], clause 9.5

Specifies the maximum time for the RIC Subscription Request event creation procedure in the Near-RT RIC.

allowedValues: [0..65535] ms

|

type: Integer
multiplicity: 0..1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: True

| + +| Attribute Name | Documentation and Allowed Values | Properties | +|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------| +| tRICEventDelete | Near-RT RIC attribute defined in O-RAN.WG3.E2AP [5], clause 9.5
Specifies the maximum time for the RIC Subscription Request event deletion procedure in the Near-RT RIC.

allowedValues: [0..65535] ms | type: Integer
multiplicity: 0..1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: True | +| tRICControl | Near-RT RIC attribute defined in O-RAN.WG3.E2AP [5], clause 9.5
Specifies the maximum time for the RIC Control Request event request procedure in the Near-RT RIC.

allowedValues: [0..65535] ms | type: Integer
multiplicity: 0..1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: True | +| tRICEventModify | Near-RT RIC attribute defined in O-RAN.WG3.E2AP [5], Clause 9.5

Specifies the maximum time for the RIC Subscription Modification procedure in the Near-RT RIC.

allowedValues: [0..65535] ms | type: Integer
multiplicity: 0..1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: True | +| tRICQuery | Near-RT RIC attribute defined in O-RAN.WG3.E2AP [5], Clause 9.5

Specifies the maximum time for the RIC Query procedure in the Near-RT RIC.

allowedValues: [0..65535] ms | type: Integer
multiplicity: 0..1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: True | +| nearRTRICID | Defined in O-RAN.WG3.E2AP [5], clause 9.2.4

allowedValues: Not applicable. | type: Integer
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: False | +| pLMNIdentity | Defined in 3GPP TS 28.658 [7], clause 4.3.26

allowedValues: Not applicable. | type: PLMNid
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: False | +| policyId | It defines the unique identifier of the policy, corresponding to the policy file.

allowedValues: Not applicable. | type: String
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: N/A
isNullable: False | +| policyType | It indicates the type of energy saving corresponding to NES policy.

allowedValues:
"TRX_CONTROL": the policy is for TRx Control (RF Channel Reconfiguration) based energy saving.
"ASM": the policy is for advanced sleep mode based energy saving. | type: ENUM
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: N/A
isNullable: False | + +| Attribute Name | Documentation and Allowed Values | Properties | +|-------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------| +| applicableTimeWindows | It defines the list of time windows at which the NES policy is applicable.

allowedValues: Not applicable. | type: TimeWindow
multiplicity: 1..*
isOrdered: False
isUnique: True
defaultValue: N/A
isNullable: False | +| sleepMode | It indicates the sleep mode (defined in ORAN-WG4.CUS specification [13], clause 7.5.3.52) corresponding to NES policy.

Allowed values are the sleep modes supported by the O-RU (defined in ORAN-WG4.CUS specification [13], clause 16.1).

allowedValues: 0, 1, 2, 3 | type: Integer
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: N/A
isNullable: False | +| antennaMask | It indicates or defines the antenna mask (defined in ORAN-WG4.CUS specification [13], clause 7.5.3.54) corresponding to NES policy.

allowedValues: Antenna mask values supported by the O-RU. | type: BitString
multiplicity: 0..1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: False | +| configuredNesPolicyList | It holds an ordered list of DNs of the NES policies that are configured for a given NRCellDU. The evaluation of the NES policy is performed by the O-DU in increasing order of their precedence in the list. The order represents the policy priorities, i.e., the policy whose DN appears first has higher priority than the policies that follow.

allowedValues: DNs of the NESPolicy MOI(s) that are name contained in the parent GNBDUFunction. | type: DN
multiplicity: 1..*
isOrdered: True
isUnique: True
defaultValue: N/A
isNullable: False | +| startCellRBAlloc | Specifies the starting position of common resource block (CRB) allocation within the available frequency resource for each cell.

This value is the offset in common resource blocks, defined in 3GPP TS 38.211[14] clause 4.4.4.3, to common resource block 0 for the applied subcarrier spacing for a cell.

allowedValues:
0 to N_grid_size - 1, where N_grid_size equals the number of common resource blocks for the BS channel bandwidth based on the subcarrier spacing applied to the cell. | type: integer
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: 0
isNullable: False | +| direction | The direction of interest for a startCellRBAlloc.

allowedValues:
BIDIRECTION, UL, DL | type: ENUM
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: BIDIRECTION
isNullable: False | +| rRMPolicyMemberList | It represents the list of RRMPolicyMember (s) that the managed object is supporting, defined in 3GPP TS 28.541[12] clause 4.3.42.
A RRMPolicyMember <> includes the PLMNId <> and S-NSSAI <>.

allowedValues: Not applicable. | type: RRMPolicyMember
multiplicity: 1..*
isOrdered: False
isUnique: True
defaultValue: None
isNullable: False | + +| Attribute Name | Documentation and Allowed Values | Properties | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------| +| numberOfPRBs |

Number of physical resource blocks, defined in 3GPP TS 38.211 [14] clause 4.4.4.4, for a RRMPolicyRBAlloc.

allowedValues:
1 to N_grid_size – startCellRBAlloc. See startCellRBAlloc for definition of N_grid_size.

This applies only to single numerology use case.

|

type: Integer
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: False

| + +| Attribute Name | Documentation and Allowed Values | Properties | +|----------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------| +| Attribute related to role | | | +| hostDN |

This attribute contains the DN of the hosting entity (e.g., NearRTRICFunction).

allowedValues: Not applicable.

|

type: DN
multiplicity: 1
isOrdered: N/A
isUnique: N/A
defaultValue: None
isNullable: False

| +| applicationDNList |

This attribute contains the DNs of the hosted applications (MOIs of the concrete IOCs inheriting from ManagedApplication).

allowedValues: Not applicable.

|

type: DN
multiplicity: 0..*
isOrdered: False
isUnique: True
defaultValue: None
isNullable: True

| + +## 5.5 Common notifications + +### 5.5.1 Alarm notifications + +This clause presents a list of notifications, defined in 3GPP TS 28.111 [16] and referenced in O-RAN O1 Interface Specification [11], that an MnS consumer may receive. The notification header attribute *objectClass/objectInstance*, defined in 3GPP TS 28.111 [16], shall capture the DN of an instance of a class defined in the present document. + +**Table 5.5.1-1: Alarm notifications** + +| Name | S | Notes | +|----------------------------------|---|-------| +| notifyNewAlarm | M | | +| notifyClearedAlarm | M | | +| notifyAckStateChanged | O | | +| notifyAlarmListRebuilt | M | | +| notifyChangedAlarm | O | | +| notifyChangedAlarmGeneral | O | | + +### 5.5.2 Configuration notifications + +This clause presents a list of notifications, defined in 3GPP TS 28.532 [10] and referenced in O-RAN O1 Interface Specification [11], that an MnS consumer may receive. The notification header attribute *objectClass/objectInstance*, defined in 3GPP TS 28.532 [10], shall capture the DN of an instance of a class defined in the present document. + +**Table 5.5.2-1: Configuration notifications** + +| Name | S | Notes | +|------------------|---|-------| +| notifyMOIChanges | O | | +| notifyEvent | O | | + +# Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.07.26 | 01.00 |

First Release

Inclusion of CRs:

  • • O1NRM Requirements
  • • Common Notifications
  • • O1 NRM Models additions including RIC
  • • O1 NRM Scope addition
  • • O1 NRM Terms addition
  • • O1 NRM Short name change
  • • O1 NRM Spec O-DU IM for NES
  • • O1 Interface Enhancement for Inter-cell Interference Suppression Control
  • • MA and RIC Model update
  • • Bi-Directional EP_E2 Model
  • • O1 NRM addition WG3 Params
  • • O1 NRM addition of EP_A1

Editorial fixes and alignments.

| +| 2024.12.06 | 02.00 |

Inclusion of CRs:

  • • Add references to the Clause 5.5 “Common notifications” for applicable IOCs
  • • Change the cardinality to allow a cell to exist without an instance of RRMPolicyRBAlloc
  • • Various updates to references as needed
  • • Various updates to fonts etc
  • • Delete all import related notes
  • • Adding requirements to follow 3GPP TS 32.160 clause 5.1
  • • Adding new attribute “numberOfPRBs” with its definition
  • • Change 3GPP references boiler plate text to Rel 18.
| \ No newline at end of file diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/0b7d9b9ee86afab230f3c4619c4a25ff_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/0b7d9b9ee86afab230f3c4619c4a25ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7bf9c06a322da0f7f5b8a2b65ca6921c2cab51c --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/0b7d9b9ee86afab230f3c4619c4a25ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:86257272a917b348d016a904eaa33eddaa7a71a92416937e8ab653523ad450fe +size 19961 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/0cd45ba3e434d7c0f76a99c8344cbabe_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/0cd45ba3e434d7c0f76a99c8344cbabe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0849fde4f5c0f786569ae5998d530366019c8620 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/0cd45ba3e434d7c0f76a99c8344cbabe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:92e342c8009c8b8bf78ac8a2592af5b62ab5df63c81925208331e8b22b9ed63e +size 160027 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/210304c3521acf4627854e72f2843931_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/210304c3521acf4627854e72f2843931_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b9cf9f79e5d82f7da7063c804415098b7993f9b1 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/210304c3521acf4627854e72f2843931_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ca963208687e4e70ed2cf10694177b096fcbc20a4cc8db1b825b58602199015 +size 160518 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/25c2d6c5db10c344abdab4367be33fb5_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/25c2d6c5db10c344abdab4367be33fb5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..10766f1cced241919deb8a6141ccafb46eb255f7 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/25c2d6c5db10c344abdab4367be33fb5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7ee75af66f8fa8b3f1d6a2bcde1e6cf073be182491c486d1164c8b099dda58d8 +size 3742 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/25de4caad63f39aa96ae4c50df78accf_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/25de4caad63f39aa96ae4c50df78accf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c035faf88e80cf1ac205f3e093c2e2027b057d0b --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/25de4caad63f39aa96ae4c50df78accf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:21185bee9524e926627c3f53059ad083d761aef31d245038ee2bb5367efa2d8d +size 131564 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/2912641e9a5b67b5775247d9f57de582_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/2912641e9a5b67b5775247d9f57de582_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f9ecadd189ad823bf4021d0cedfc965a025e14c0 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/2912641e9a5b67b5775247d9f57de582_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cda626ca7de0b82233863ee980f3376cf57e62fd2aae721d84aeeb29cd9b0b4c +size 137695 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/305f926956a1bab03d551c9bce1b8f24_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/305f926956a1bab03d551c9bce1b8f24_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dcad0099b981dc0a7eeb1a6d8365a63bcaefb2a3 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/305f926956a1bab03d551c9bce1b8f24_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2baf58fff45417c22a979a6d68312df68623753464ca6b84028cc73f91ddd3f6 +size 161928 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/31dc9614a9aa28907d66f24a332b6d55_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/31dc9614a9aa28907d66f24a332b6d55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0b95a492cb2e06a3892885340598246f273a1e38 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/31dc9614a9aa28907d66f24a332b6d55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7bda7a55ebb463bd91c4af58d681cbae665aecae5216029f8e4114f269152363 +size 61386 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/3310e16b57069122a94db2a3f1864c94_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/3310e16b57069122a94db2a3f1864c94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..16e9b4db7bbe200203ca6b3a22a2c37b8c1dbaca --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/3310e16b57069122a94db2a3f1864c94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:27481cd94b160daf2840aa2575e5a3670675ed274600c061d315c3e1410fa8bd +size 12550 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/3aff65ff46ea58154efa7094a028795c_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/3aff65ff46ea58154efa7094a028795c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c01962c52c28204cb41ecef245a4b35e43d926e5 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/3aff65ff46ea58154efa7094a028795c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1f688e59dd75eaab838d083d4f796e1229ac39ed5041bf99d4993dfc6a2db927 +size 22555 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/416e9d62fad1203a3dfeaeee3b5cd8ca_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/416e9d62fad1203a3dfeaeee3b5cd8ca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7dc409fc2c4f657dcb32bae949df4a322f9da601 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/416e9d62fad1203a3dfeaeee3b5cd8ca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7c01f511f77b6c237f0732fc88a67aa62fd7afb295070a960ec534c3ac2ab394 +size 3745 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/42e02540f640bf063e28cc29863446fa_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/42e02540f640bf063e28cc29863446fa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6757c5809e882e7c82261dc885806147b8791754 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/42e02540f640bf063e28cc29863446fa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9b21cc052e0362cede61ae6ee7ba809555e13cdf5a8f5a75368cf53a195e3a2 +size 86117 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4526e42435746ac140b8391e2c984873_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4526e42435746ac140b8391e2c984873_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6c6034b0b53563e4bb254409d539f83867854f5c --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4526e42435746ac140b8391e2c984873_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54195e0a8ed33c9bf31fc5aedc1ec0189e9c314f696ca8d7e071fc90aa56ec9f +size 3544 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4a96ce4485e9be13ca21681c88c01791_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4a96ce4485e9be13ca21681c88c01791_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5e93794f288ea219eebf604b5ee53e5589e50ef0 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4a96ce4485e9be13ca21681c88c01791_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:280a30674ba856a9be985f9c29869377fb162bde39447da8d63e099092e9d834 +size 3681 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4b54d3c9163cf1d4f8db8b55169b96cf_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4b54d3c9163cf1d4f8db8b55169b96cf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fb9d4b88925994eda56a6d3cc03b5d6d82c283f1 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4b54d3c9163cf1d4f8db8b55169b96cf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:422efc1ea7d20c1576fbed30a1d793639024bcd639a7de961a19d9af8a9b7793 +size 73191 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4f25b03688e72b293ac709546448a47a_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4f25b03688e72b293ac709546448a47a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ac70447c4b85ca96ec0b9a1030db9c1dc6bafa97 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/4f25b03688e72b293ac709546448a47a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e8f4492fc1c85acc7173992916a7d5755b3870fe34095622c25d28c5c1835673 +size 3647 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5033dca804ae78eacb57453ab177ae51_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5033dca804ae78eacb57453ab177ae51_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d36d5fb1cafeb5f203d7a006b5474f92a4308b3 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5033dca804ae78eacb57453ab177ae51_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f87bf58127bf0709f3dee5597fcdf47b7fd5e087b2d4f1b0cf25b72ec9bed7bf +size 17687 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5161f7b155f9777fbd1c86b540a031e0_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5161f7b155f9777fbd1c86b540a031e0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ac7ad68c07993f100fbc471d4487c6cafe2052f6 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5161f7b155f9777fbd1c86b540a031e0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f53832f3000ca39752c105ab46a2146f16c2ab6ead11f395559f4e65202c943e +size 168796 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5c5c3969799ce77a583c12ec75ab0f36_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5c5c3969799ce77a583c12ec75ab0f36_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8ae17ceb423ca4ea3223757b0121afc67bffd743 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5c5c3969799ce77a583c12ec75ab0f36_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c907d2e206622b9e9ded5fa572c0d5582fea794d7b78befdb636f8e6f9b5d1d +size 175388 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5c7bac199414e8d7c00e3ee208d8d0e5_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5c7bac199414e8d7c00e3ee208d8d0e5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..acda29c9eb30072a862f6d6be052c513c7c49f85 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/5c7bac199414e8d7c00e3ee208d8d0e5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:30aec4e0a597cce1fe05bc99c57526e5ed77dcb59ad914a3223f07f9d5915866 +size 257856 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/61883bad8eadb8053d344b1d2ea76fcd_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/61883bad8eadb8053d344b1d2ea76fcd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..00d117d31d360cdeea94a5d7e9ae67c22f1ea1ba --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/61883bad8eadb8053d344b1d2ea76fcd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:37c73ee55635c562009fedf8ed231d7cdb2f8497125e3b128b9ade450fa24a34 +size 3594 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/63e256b2796736d556073f0f6b4b07db_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/63e256b2796736d556073f0f6b4b07db_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..442604c7a46685dcf1920f3b77eb3a748a8dbe3e --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/63e256b2796736d556073f0f6b4b07db_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a390b92757d16c1efecdbf9e17dd0bdfbcbc8195d9923ddbe18597b0d3bf3fff +size 113332 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/64513b61d6ee4d1816ca797a5d8c4181_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/64513b61d6ee4d1816ca797a5d8c4181_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4a14cd772f1849a88fcd10b7c31e49d8efbaa5f3 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/64513b61d6ee4d1816ca797a5d8c4181_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8d022e6f139cea95886d9c72dcb7d38a868565999edfaa0b546f0c7a98210d54 +size 40385 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/6d3eecbb74f03209d941072fca0bdcb8_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/6d3eecbb74f03209d941072fca0bdcb8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..400ebc05246ac08cc6690fa8fc1c998e9ecee67c --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/6d3eecbb74f03209d941072fca0bdcb8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6d11b99e857c0c84d8f8d709b491a61ad08cdad8548a6b24af8d7594714a7be0 +size 20959 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/747b8d456712a3f332d2adf596af295e_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/747b8d456712a3f332d2adf596af295e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fb5541fa3b3c488bb413480f257b1444538aa46b --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/747b8d456712a3f332d2adf596af295e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b9099d1845068e10e67f791f5599d76c41b6dbf31d8b3ecf6ea083868a0aa7c6 +size 186367 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/750e37a43d9e413da3cf998c777a9ace_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/750e37a43d9e413da3cf998c777a9ace_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8df0d55e6bb4c11540bd230657b23b4f703d01d9 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/750e37a43d9e413da3cf998c777a9ace_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a723ce17044d67c63da40b005c46b132d5e0dbe9ced462e9db2c3c85933e748f +size 128708 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/876a99286941ae103af77ab5220c0422_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/876a99286941ae103af77ab5220c0422_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..19892489b7ba007fab7b67c6d334673dba86f90f --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/876a99286941ae103af77ab5220c0422_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3788becb77752c184519750de5d1c59d0cfdda81e348b1f9b7f77413ebf40212 +size 180287 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/8d63dd406ef258f41f2c89fb636dfd28_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/8d63dd406ef258f41f2c89fb636dfd28_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3e077c60e5871f362b7086c935617e6d415ab105 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/8d63dd406ef258f41f2c89fb636dfd28_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:df272ba432925eeeb037ca1f64aa86e0b592ae05164323c2b01cc5f40538bbeb +size 37424 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/8de501114191483006c6ce93c404ecb7_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/8de501114191483006c6ce93c404ecb7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..00a5448d11381b2deae90dba07d560816acc20f2 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/8de501114191483006c6ce93c404ecb7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b6ab8702442f353dc5198493c730e10740a7dc010eae1b935c4f5da53708e674 +size 16889 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/908e7621c8c152222146c02caeedd457_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/908e7621c8c152222146c02caeedd457_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a344a2ac7dd50e0dc200c1a8432e61a55eeed4c7 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/908e7621c8c152222146c02caeedd457_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b11f9b936a9a5c0e6296fba2e62e206b98391dbe14316e5f9ec7c37605d987f7 +size 223186 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/934ff10062eea913a97aeae3a566f93d_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/934ff10062eea913a97aeae3a566f93d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a2267c1093b02c91f3c67f9be18ce01505e61bcd --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/934ff10062eea913a97aeae3a566f93d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5920be3ec39abab8b6d83ff6cd20eaa81ea55d9a66b3e034c9d9a78082a9df5d +size 49591 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/974bf616440322c1bc8c2498f53bdc5c_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/974bf616440322c1bc8c2498f53bdc5c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0448485963d8af342e8a2d538f1e142aaa7dc956 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/974bf616440322c1bc8c2498f53bdc5c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3bf6370b674792c63fc119a90bc75d14bc8ee3c96678266e41bc67d0ce99db0d +size 22502 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/9f77c8e8a3f647adf0cd8fdb174ae2c1_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/9f77c8e8a3f647adf0cd8fdb174ae2c1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dc2afd294b442bbc4ad59fccc0108be0dfe36993 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/9f77c8e8a3f647adf0cd8fdb174ae2c1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9d7f405c20f7f351a3bf6ad876aaad0642a6a9ffbdd6f6ea2c2dd93bb3908318 +size 75607 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a0afbdb0919528ac7726f7747d9f4a4a_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a0afbdb0919528ac7726f7747d9f4a4a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6bb464156d029b4b66e10d0c94b44fd1ac68e499 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a0afbdb0919528ac7726f7747d9f4a4a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5bbbadecb7e4c5e3da445819e1f03fb7bec5d6b0f1d977e4765f79237bf047c7 +size 149588 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a0fa1fe97028ce426ccac396ca4d5f18_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a0fa1fe97028ce426ccac396ca4d5f18_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aa4b272384bcb9ab8abc800b9e092c384e0737be --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a0fa1fe97028ce426ccac396ca4d5f18_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:402a7344ba3383eb81749e9fe266e921fd852fdbc609dbc71bbe07b03f4f2578 +size 46315 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a179f4bd7ca6021e452bf2ccca66762e_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a179f4bd7ca6021e452bf2ccca66762e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..402729fe17aab7f29e9b23e9b197fb0dd63424a6 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a179f4bd7ca6021e452bf2ccca66762e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:22f7d63d639df435e012bc606c36695aa2129ab7aff6065d659cd5516eba38f0 +size 21122 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a216855334a88c32b07e1005bf7cb7a6_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a216855334a88c32b07e1005bf7cb7a6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4171e4e314ea7ee661461fbddd58d84111491e79 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a216855334a88c32b07e1005bf7cb7a6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:44c7ddbc6175e7ac1d753624cd76141dfbceed63490dfd9f34ca61a3af6de948 +size 3734 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a51b29f0dca432d963d302da85759e05_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a51b29f0dca432d963d302da85759e05_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f7d5f56ae6fa586bdcc930ffc50ff25d09b2d3be --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a51b29f0dca432d963d302da85759e05_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:663b8ebc5580d8b4244536e4ed02495dcaf20a0af4a2b3fc6730fa7c3806a45e +size 29104 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a558e09c0e45f80d4f265a961213e71c_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a558e09c0e45f80d4f265a961213e71c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..81f0bdd637c748fa9be9f60d2df1395f225eb225 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/a558e09c0e45f80d4f265a961213e71c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:06caa0033fbda3bf887f3010daaf151b9ccb676270388dec6ab2189286e42555 +size 35887 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/b27cab4efd103bbfc3468cb24d8cad92_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/b27cab4efd103bbfc3468cb24d8cad92_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7ab99bacb58d488a7b4c85de8fb8d71ea7f41d12 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/b27cab4efd103bbfc3468cb24d8cad92_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0ffab1fcc9ceecc222957c603a97761040b59521f2d09760053d183e3779af83 +size 49512 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/bde4b1a0d79776c427cb4743b96ba497_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/bde4b1a0d79776c427cb4743b96ba497_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1a093a6f1c9c03a132480b02dd9afbdc436711d8 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/bde4b1a0d79776c427cb4743b96ba497_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c62906100902eac1506ea44155deea15c9192c247182212b41b5ee6da3143502 +size 3743 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/c6c96261ac087eca2b03c011de515c76_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/c6c96261ac087eca2b03c011de515c76_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b6053ce9b5d65d7c4ea7ce5d75af38b667168df9 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/c6c96261ac087eca2b03c011de515c76_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b60a1e693cb6a0d41f1a731414384b4636cd62d3af23d0799ca1b4100e098b64 +size 3678 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d1a57bd811eacc012a5cc5f4a6b702d9_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d1a57bd811eacc012a5cc5f4a6b702d9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ce151ece8b53448ded8f3f8c61fec5b939aedefe --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d1a57bd811eacc012a5cc5f4a6b702d9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:674b3a29ec5924f415354940aeb3c632240de2e3557f3bc86896cf72b20f4e2c +size 69514 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d283d0be8a577dc21df69b620d4ed224_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d283d0be8a577dc21df69b620d4ed224_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..80e702ba80be9121bdb5b9283198394bbf89e81f --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d283d0be8a577dc21df69b620d4ed224_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:109cb72374dc3a70bfd79a1b5f9734d08a7964464c937045d1aef19d67f73dc1 +size 220904 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d32216ae53712b6faab76d5e0690d94c_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d32216ae53712b6faab76d5e0690d94c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8732871d1b39bb91ea3c09638fe8bafbc2b14d1f --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d32216ae53712b6faab76d5e0690d94c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:128e752f892799a3e072aa4fe201f7f452e6a8d05e59826d9e29d31cef03661b +size 168170 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d3c8e700305b1b4adc8d3090b510279e_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d3c8e700305b1b4adc8d3090b510279e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..185f10784c9ad7f42954fbb602c7fb43dc5a82f5 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/d3c8e700305b1b4adc8d3090b510279e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e66ce602fe932ff4e5c049eb93d26e9650d70709d498bb8179c6b051a9713397 +size 3674 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/dee332e17a216365389ffa675e3d3918_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/dee332e17a216365389ffa675e3d3918_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..92fd99f881a18b01f3100096f2a67b5e8e6d88a8 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/dee332e17a216365389ffa675e3d3918_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1d177467c4bc7912b2f7f448f95eba714e9ce9d83a74746e167ccbdca53d24cb +size 3683 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/e5e54902ca1a9d818cf12df7adee3f22_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/e5e54902ca1a9d818cf12df7adee3f22_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..34ef168f0c8fffb8f8b00baf6e26188510575d80 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/e5e54902ca1a9d818cf12df7adee3f22_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9d67667c549b70982ea34a1062be1e67eca80393b69bc85a60a58618da05718c +size 57367 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/e774417ec245122bc766ab0778a122ba_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/e774417ec245122bc766ab0778a122ba_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ce590527f953943fdd7ff686d4c8adf0660b7ba --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/e774417ec245122bc766ab0778a122ba_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cb8ba72e36f955800267fddfd03bc343f7718e1b224f40bd06dbfe2591587a60 +size 3765 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fbe4e43afa685ec1028a4a851802bfeb_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fbe4e43afa685ec1028a4a851802bfeb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f48235a7619763d1ce5d13fb3e0bab99a63ab8df --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fbe4e43afa685ec1028a4a851802bfeb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a043dc3b7a5ab117c84f63d03efba48916efe9aa635050a0ba858a44cf42db1d +size 3752 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fc136acb002f3c20c16bba928af787f6_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fc136acb002f3c20c16bba928af787f6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..163a7ebace578d56fad616829941897224ab3e2e --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fc136acb002f3c20c16bba928af787f6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6d865541c41800c213848ea1070f48ccea5eecf18ace227949988a0b79ac7051 +size 3590 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fc4134aefccbb95052b23a446e9b6e7f_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fc4134aefccbb95052b23a446e9b6e7f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..52540f9d3916ac242d9cc968b6435641f3ff1e8d --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fc4134aefccbb95052b23a446e9b6e7f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:310b5bdcb6b1d89f46ec9fd86b392cb492ffe87c75232f94be733c9384884599 +size 60847 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fdc3d58a4882ee60f5cd7ee8af4b40b9_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fdc3d58a4882ee60f5cd7ee8af4b40b9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2e88def00e8861349246902645aeae05be40798e --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/fdc3d58a4882ee60f5cd7ee8af4b40b9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:72d886917785a461a1ad3d5acd256a5196e1ea23f9f7f7a60c5fda76bb36f0f9 +size 161345 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/ff02d3bcd91720ebb7270e7b1833e525_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/ff02d3bcd91720ebb7270e7b1833e525_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b1595a8a7a76d6ce5694c61e79828aaf6066b918 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/ff02d3bcd91720ebb7270e7b1833e525_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:97caa4b80baf42543bd9f1fd42aceffb340a8fe1d3738433601257ae479ce5ff +size 165904 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/ffc23dcb72df118c8ca591af09bf17d6_img.jpg b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/ffc23dcb72df118c8ca591af09bf17d6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1f63e6b52236b7dbd206f2e5fbc8eef9f61e042d --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/ffc23dcb72df118c8ca591af09bf17d6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:502e1f5ee958288d91d4c06c924c71fc2de2c5f6206355e471e2f6fdcd35ed8d +size 117639 diff --git a/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/raw.md b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..2131224a270502c13d8bc2ef873b0d701b77184d --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00/raw.md @@ -0,0 +1,3157 @@ + + +# --- O-RAN Work Group 10 + +# O-RAN Operations and Maintenance Architecture + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|----------------------------------------------------------------------------------|----| +| Foreword..... | 4 | +| Modal verbs terminology ..... | 4 | +| 1 Scope ..... | 5 | +| 2 References ..... | 6 | +| 2.1 Normative References..... | 6 | +| 2.2 Informative references ..... | 6 | +| 3 Definition of terms, symbols and abbreviations..... | 7 | +| 3.1 Terms ..... | 7 | +| 3.2 Symbols ..... | 7 | +| 3.3 Abbreviations..... | 7 | +| 4 O-RAN Overview ..... | 8 | +| 4.1 Scope and Objectives..... | 8 | +| 4.2 End-to-End OAM Use Cases (informative)..... | 8 | +| 4.2.1 O-RAN Provisioning Use Case..... | 8 | +| 4.2.2 O-RAN Measurement Data Collection Use Case..... | 13 | +| 4.2.3 O-RAN Configuration..... | 20 | +| 4.2.4 Use Cases for O-RU Hierarchical Management Architecture Model ..... | 23 | +| 4.2.5 Network Energy Saving Use Cases..... | 31 | +| 4.2.6 Policy management ..... | 36 | +| 5 OAM Architecture..... | 39 | +| 5.1 Architectural Principles ..... | 39 | +| 5.1.1 Alarm Dictionary Overview ..... | 40 | +| 5.1.2 Alarm Dictionary Association with O-RAN Entities and Content..... | 40 | +| 5.1.3 Compatibility for O1 Interface ..... | 41 | +| 5.2 Architecture Requirements ..... | 42 | +| 5.2.1 Functional Requirements..... | 42 | +| 5.2.2 Non-Functional Requirements ..... | 43 | +| 5.2.3 Security Requirements ..... | 43 | +| 5.3 Reference Architecture ..... | 44 | +| 5.3.1 Architectural Building Blocks..... | 44 | +| 5.3.2 Basic OAM Architecture..... | 45 | +| 5.3.3 O-RU Management Models and Managed Deployment Options..... | 48 | +| 5.3.4 Network Functions Deployed behind a NAT ..... | 48 | +| 5.3.5 Relationships between the O1 NRM entities and Architectural entities ..... | 49 | +| 6 Application Lifecycle Management (LCM)..... | 50 | +| 6.1 Scope ..... | 51 | +| 6.1.1 Application Package Model ..... | 51 | +| 6.1.2 App Development Lifecycles..... | 53 | +| 6.1.3 App Onboarding Lifecycles ..... | 54 | +| 6.1.4 App Operation Lifecycles ..... | 56 | +| 6.2 Common Application Lifecycle Conclusions ..... | 57 | +| 6.2.1 Information Consumers..... | 57 | +| 6.2.2 Solution SW Package Lifecycle ..... | 58 | +| 6.2.3 Onboarded SW Package Lifecycles ..... | 58 | +| 6.2.4 Onboarded ManagementDescriptor Certification Lifecycle ..... | 58 | +| 6.2.5 Application Training Lifecycle ..... | 59 | +| 6.2.6 Deploy Instance Lifecycle..... | 59 | +| Annex A (informative): Cardinality ..... | 60 | +| Annex B: Void..... | 61 | + +| | | +|------------------------------------------------------------------------------------|----| +| Annex C (informative): Common App Lifecycle Flows ..... | 62 | +| C.1 Solution SW Package Lifecycle ..... | 62 | +| C.2 Onboarded SW Package Lifecycle ..... | 66 | +| C.3 Onboarded ManagementDescriptor Certification Lifecycle ..... | 70 | +| C.4 Application Training Lifecycle ..... | 72 | +| C.5 Deploy rApp Instance Lifecycle ..... | 73 | +| Annex D (normative): Shared O-RU ..... | 76 | +| D.1 Introduction ..... | 76 | +| D.2 Single Operator Shared O-RU ..... | 76 | +| D.2.1 O-DU(s) roles ..... | 76 | +| D.2.2 Configuring O-RU ..... | 76 | +| D.2.3 Supervision Monitoring per O-DU ..... | 77 | +| D.2.4 NETCONF call home ..... | 77 | +| D.3 Multi Operator Shared O-RU ..... | 77 | +| D.3.1 O-DU(s) roles ..... | 77 | +| D.3.2 Configuring O-RU general OAM related configuration ..... | 78 | +| D.3.3 Managing O-RU general OAM related functions ..... | 78 | +| D.3.4 NETCONF server user account provisioning for shared resource operators ..... | 78 | +| D.3.5 NETCONF call home ..... | 78 | +| D.3.6 Enhanced sro-id based NETCONF access control ..... | 79 | +| D.3.7 Supervision Monitoring per O-DU ..... | 79 | +| D.3.8 Processing element configuration ..... | 79 | +| D.3.9 Carrier Partitioning and Configuration in Shared O-RU ..... | 79 | +| D.3.10 Notification of configuration updates ..... | 79 | +| D.3.11 Shared O-RU Reset Co-ordination ..... | 79 | +| D.3.12 Locked administrative state ..... | 80 | +| D.3.13 Antenna calibration ..... | 80 | +| D.3.14 Shared O-RU with antenna line devices ..... | 80 | +| D.3.15 Shared O-RU operation in combination with shared cell ..... | 80 | +| D.4 Content of Open Fronthaul M-Plane ODU ID ..... | 80 | +| D.5 Content of Open Fronthaul M-Plane SRO ID ..... | 80 | +| Annex E (informative): Network Energy Saving ..... | 81 | +| E.1 Introduction ..... | 81 | +| E.2 Cell and carrier deactivation / activation ..... | 81 | +| E.2.1 Flow description ..... | 81 | +| E.3 Void | 83 | +| E.4 Void | 83 | +| Annex F (informative): Policy Example ..... | 84 | +| Annex ZZZ: Void ..... | 85 | +| Annex (informative): Change History ..... | 86 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG10 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e., technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +This document defines O-RAN OAM architecture and interface functions. The OAM architecture supports a variety of management network deployment models, including the model of management entities (NMS/EMS/MANO) connecting directly to NEs, and the indirect connection (e.g., Open Fronthaul M-Plane involved) model. A separate OAM interface document provides details of the functions and protocols conveyed over the interface, that include management functions, procedures, operations, and corresponding solutions. + +# 2 References + +## 2.1 Normative References + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN TS O-RAN.WG4.MP.0: "O-RAN Management Plane Specification" (referred to as "OFH M-Plane") +- [2] O-RAN TS O-RAN.WG10.O1-Interface: "O-RAN O1 Interface Specification" (referred to as "O1-Interface") +- [3] O-RAN TS O-RAN.WG10.Information Model and Data Models: "O-RAN Information Model and Data Models Specification" (referred to as "IM/DM") +- [4] O-RAN TS O-RAN.WG11.SecReqSpecs: "O-RAN Security Requirements and Controls Specifications" (referred to as "SecReqSpecs") +- [5] O-RAN TS O-RAN.WG10.O1PMeas: "O-RAN O1 Performance Measurements Specification" (referred to as "O1-PMeas") +- [6] O-RAN TS O-RAN.WG1.Use-Cases-Detailed-Specification: "O-RAN Use Cases Detailed Specification" (referred to as "UC DetailedSpec") + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area: + +- [i.1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications" +- [i.2] 3GPP TS 28.622: "Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS)". +- [i.3] 3GPP TS 28.532: Management and orchestration; Generic management services +- [i.4] 3GPP TS 28.533: Management and orchestration; Architecture framework +- [i.5] 3GPP TS 28.550: Management and orchestration; Performance assurance +- [i.6] Void +- [i.7] O-RAN White Paper: "O-RAN: Towards an Open and Smart RAN", October 2018 +- [i.8] O-RAN TS O-RAN.WG6.ORCH-USE-CASES, "O-RAN Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN" (referred to as "CLD-ORCH-UC") + +- [i.9] O-RAN TS O-RAN.WG6.O2-GA&P: “O-RAN O2 Interface General Aspects and Principles” (referred to as "O2-GA&P") +- [i.10] O-RAN TS O-RAN.WG1.OAD: “O-RAN Architecture Description” (referred to as "OAD") +- [i.11] Void +- [i.12] RFC 6241, “Network Configuration Protocol (NETCONF)”, IETF, June 2011 +- [i.13] Void +- [i.14] O-RAN TS O-RAN.WG4.CUS.0: "O-RAN Control, User and Synchronization Plane Specification" (referred to as "OFH CUS-Plane") +- [i.15] 3GPP TS 23.501: "System Architecture for the 5G System (5GS)" +- [i.16] O-RAN TS O-RAN.WG10.NRM: "O-RAN O1 Network Resource Model Specification" (referred to as "O1-NRM") +- [i.17] 3GPP TS 32.156: “Telecommunication Management; Fixed Mobile Convergence (FMC) Model repertoire” +- [i.18] O-RAN TR O-RAN.WG1.NESUC: "Network Energy Saving Use Cases Technical Report" (referred to as "NESUC") + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [i.1], 3GPP TS 28.533 [i.4], OAD [i.10], and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [i.1], 3GPP TS 28.533 [i.4], and OAD [i.10]. + +**Service Planning:** The activity of a Service Operator around certifying a solution configuration for deployment into their network. + +**Service Provider:** A network provider who is planning to deploy applications into their network. + +**Solution Provider:** An application developer who delivers applications to Service Providers. + +## 3.2 Symbols + +VOID + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [i.1], 3GPP TS 28.533 [i.4], OAD [i.10], and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [i.1], 3GPP TS 28.533 [i.4], and OAD [i.10]. + +| | | +|------|------------------------------------| +| ALD | Antenna Line Device | +| ASM | Advanced Sleep Mode | +| CMT | Container Management Technology | +| CNA | Cloud Native Application | +| CNAD | Cloud Native Application Developer | +| CNF | Cloud-native Network Function | +| COTS | Commercial Off-the-Shelf | +| CP | Cloud Provider | +| DMS | Deployment Management Service | + +| | | +|-------|------------------------------------------------| +| DS | Data Store | +| EMS | Element Management System | +| ESP | Energy Saving Policy | +| FTP | File Transfer Protocol | +| FTPeS | Explicit SSL File Transfer Protocol | +| FOCOM | Federated O-Cloud Orchestration and Management | +| LCM | Lifecycle Management | +| MANO | Management and Orchestration | +| MMP | Meet-Me-Point | +| NAT | Network Address Translation | +| NFO | Network Function Orchestration | +| NFV | Network Function Virtualization | +| PCP | Port Control Protocol | +| RTE | Run Time Environment | +| SDK | Software Development Kit | +| SDLC | Software Development LifeCycle | +| SFTP | SSH File Transfer Protocol | +| UPNP | Universal Plug-N-Play | +| VNF | Virtualized Network Function | +| VNFD | Virtualized Network Function Descriptor | + +# 4 O-RAN Overview + +## 4.1 Scope and Objectives + +The O-RAN OAM Architecture identifies management services, managed functions and managed elements supported in O-RAN, including the interworking between service management and orchestration and other O-RAN components such as infrastructure management. Requirements are derived from end-to-end OAM use cases, using the initial provisioning of O-RAN service across VNFs and PNFs as the primary use case. The architecture identifies the interfaces between O-RAN Service Management and Orchestration and Managed Elements for different models and example deployment options. It provides a description of the LifeCycle Management for applications delivered from a Solution Provider to a Service Provider/Network Operator. + +## 4.2 End-to-End OAM Use Cases (informative) + +### 4.2.1 O-RAN Provisioning Use Case + +Editor's note: The content of this clause is no longer technically relevant and needs to be reviewed and revised. + +#### 4.2.1.1 Basic Objective + +In the O-RAN architecture, the radio side includes Near-RT RIC, O-CU-CP, O-CU-UP, O-DU, and O-RU Network Functions (NFs). The management side is comprised of the Service Management and Orchestration Framework (and thus the Non-RT RIC). In the NFV environment, O-RAN Network Functions can also be implemented in a virtualized form, and thus include an Infrastructure layer (e.g., COTS/White Box/Peripheral hardware and virtualization layer) based on an O-Cloud. + +The current use case focuses on O-RAN Network Function deployment rather than physical construction. According to the radio coverage requirements, operators may deploy the O-RAN NFs on dedicated physical resources and/or virtualized resources in a specific area. + +This use case assumes that the O-RAN NFs are deployed based on a Network Design using Virtualized Network Functions (VNFs) for centralized functions and Physical Network Functions (PNFs) for functions closer to the customer, so that the sequence calls for deployment of VNFs for the Near-RT RIC, O-CU-CP and O-CU-UP first followed by PNFs for the O-DU and O-RU. Note: RF functions are always realized as PNFs, but the O-DU can be realized as a PNF or VNF; this document uses PNF as an example to illustrate the associated OAM flows. + +It is also assumed that secure network connectivity is already available between RAN components. + +#### 4.2.1.2 Entities/Resources Involved + +To support the O-RAN network provisioning, the Service Management and Orchestration Framework needs to support the following capabilities: + +- O-RAN NF deployed in selected area + - a) For non-virtualized parts, the Service Management and Orchestration Framework supports the deployment of PNFs on the target dedicated physical resources which satisfy the coverage requirements, with management through the O1 interface. + - b) For VNFs, the Service Management and Orchestration Framework has the capability to interact with the O-Cloud to perform NF life cycle management, e.g., instantiate the VNF on the target infrastructure through the O2 interface (e.g., indicate the selected geo-location for each VNF to be instantiated, where close to the PNFs). + - c) The Service Management and Orchestration Framework has the capability to consume the provisioning management service through the O1 interface to manage the configuration of the NF, details are described in O1-Interface [2]. +- O-RAN network provisioning + - a) Based on the deployed NFs, the Service Management and Orchestration Framework configures the IP addressing, etc. in the PNFs and VNFs to support connectivity between them (this operation may also be performed during the instantiation steps). + - b) Operators can operate and maintain the network dynamically through the O1 and/or O2 interface by means of: + - i. Reconfiguration of the NFs + - ii. System update (usually refers to software management, without adding NFs) and system upgrade (the NFs can be added/removed/modified) + +According to above, the Service Management and Orchestration Framework together with the O-Cloud implements the O-RAN NF deployment and provisioning, creating an O-RAN network to provide service to consumers. + +#### 4.2.1.3 Solutions + +Table 4.2.1.3-1 shows the O-RAN provisioning procedures. + +**Table 4.2.1.3-1: O-RAN provisioning** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | O-RAN provisioning | | +| Actors and Roles | [1]. Service Management and Orchestration Framework: NFO, OAM Functions, Non-RT RIC
[2]. O-Cloud: DMS
[3]. PNF
[4]. VNF | | +| Assumptions | | | +| Pre-conditions | [1]. The Service Management and Orchestration Framework and O-Cloud are connected and interact.
[2]. O-Cloud supports platform and resource management.
[3]. The PNF was constructed/installed but not activated.
[4]. The VNF Software Package has been uploaded to the O-Cloud.
[5]. Secure network connectivity is already available between RAN components. | | +| Begins when | The network operator/manager decides to deploy an O-RAN network in specific geo-location | | +| Step 1 (M) | The service designer deploys Service Model and Artifacts to SMO | | +| Step 2 (M) | SMO on boarding the VNF Descriptors for the service to the O-Cloud | | +| Step 3 (M) | The radio planner orders RAN Service Deployment | | +| Step 4 (M) | The SMO initiates the O-RAN Service instantiation | | +| Step 5 (M) | The SMO interacts with O-Cloud to instantiate Near-RT RIC based on Near-RT RIC VNFD | | +| Step 6 (M) | The O-Cloud creates VNF of Near-RT RIC | | +| Step 7 (M) | The O-Cloud notifies the SMO the Near-RT RIC has been instantiated and SMO updates its inventory | | +| Step 8 (M) | The SMO configures the Near-RT RIC | | +| Step 9 (M) | The O-Cloud creates VNF of O-CU-CP | | +| Step 10 (M) | The O-Cloud notifies the SMO the O-CU-CP has been instantiated and SMO updates its inventory | | +| Step 11 (M) | The SMO prepares configuration, e.g., Near-RT RIC related | | +| Step 12 (M) | The SMO configures the O-CU-CP | | +| Step 13 (M) | The SMO interacts with the O-Cloud to instantiate O-CU-UP. For multiple O-CU-UP VNF, steps 13 to 17 are repeated | | +| Step 14 (M) | The O-Cloud creates VNF of O-CU-UP | | +| Step 15 (M) | The O-Cloud notifies the SMO the O-CU-UP has been instantiated and SMO updates its inventory | | +| Step 16 (M) | The SMO prepares configuration, e.g., Near-RT RIC, O-CU-CP related | | +| Step 17 (M) | The SMO configures the O-CU-UP | | +| Step 18 (O) | The SMO deploys xApp to the Near-RT RIC | | +| Step 19 (O) | After the above steps the Near-RT RIC may subscribe to the O-CU-CP via the E2 interface | | +| Step 20 (O) | After the above steps the Near-RT RIC may subscribe to the O-CU-UP via the E2 interface | | +| Step 21 (M) | SMO adds O-DU into inventory, e.g., with an O-DU.ID for each O-DU. For multiple O-DU this step is repeated | | +| Step 22 (M) | SMO adds O-RU into inventory in the O-DU record, e.g., with an O-RU.ID for each O-RU. For multiple O-RU this step is repeated | | +| Step 23 (M) | The field technician powers on the O-DU | | +| Step 24 (M) | The O-DU sends Registration to the SMO
Note: the controller address is determined | | +| Step 25 (M) | The SMO registers the O-DU as on-line | | +| Step 26 (M) | The SMO prepares O-DU configuration, e.g., related information from Near-RT RIC and O-CU-CP, O-CU-UP | | +| Step 27 (M) | The SMO configures the O-DU | | +| Step 28 (O) | The SMO may deploy xApp to Near-RT RIC | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Step 29 (O) | After the above steps the Near-RT RIC may interact with O-DU via E2 interface | | +| Step 30 (M) | The field technician powers on the O-RU | | +| Step 31 (M) | The O-RU registers to the O-DU
Note: additional actions for hybrid case not shown | | +| Step 32 (M) | The O-DU sends Config Change Notification to the SMO indicating O-RU on-line | | +| Step 33 (M) | The SMO registers the O-RU as on-line | | +| Step 34 (M) | The SMO configures the O-RU via O-DU | | +| Step 35 (M) | The O-DU gets O-RU configuration information from the SMO | | +| Step 36 (M) | The O-DU configures the O-RU | | +| Step 37 (M) | O-RU Registration is sent to the SMO. | | +| Step 38 (M) | The SMO registers the O-RU as on-line | | +| Step 39 (M) | The SMO prepares O-RU configuration, e.g., including co-related O-DU. | | +| Step 40 (M) | The SMO configures the O-RU | | +| Ends when | All O-RAN network functions needed for service have been registered and configured; SMO holds current inventory of all O-RAN network functions | | +| Exceptions | Not applicable | | +| Post Conditions | The O-RAN network has been established and is ready to provide service to customers | | +| Traceability | REQ-M&O-FUN1, REQ-M&O-FUN2, REQ-M&O-FUN3, REQ-M&O-FUN4, REQ-M&O-FUN5, REQ-M&O-FUN6, REQ-M&O-FUN9, REQ-M&O-FUN10 | | + +![Sequence diagram for O-RAN Service Deployment and Configuration. The diagram shows interactions between Personnel (Service Designer, Radio Planner, Field Technician), Service Management & Orchestration Framework (NFO, OAM Functions, Non-RT RIC), O-Cloud (DMS), and O-RAN Components (Near-RT RIC, O-CU-CP, O-CU-UP). The process includes steps for service design, deployment, instantiation, configuration, and subscription management.](876a99286941ae103af77ab5220c0422_img.jpg) + +``` + +sequenceDiagram + participant Personnel as Personnel +Service Designer +Radio Planner +Field Technician + participant SMO as Service Management & Orchestration Framework +NFO +OAM Functions +Non-RT RIC + participant OCloud as O-Cloud +DMS + participant ORAN as O-RAN Components +Near-RT RIC +O-CU-CP +O-CU-UP + + Note over Personnel, SMO: 1 Deploy Service Model and Artifacts + Note over SMO, OCloud: 2 On boarding the VNF Descriptors for the service + Note over Personnel, SMO: 3 Order RAN Service Deployment + Note over SMO: 4 Instantiate (O-RAN Service) + Note over SMO, OCloud: O-RAN Service Resource VNF Deploy + Note over SMO: O-RAN Virtualized Part Instantiation and Configuration + Note over SMO: 5 Instantiate (Near-RT RIC_VNFD) + Note over SMO: Details of VNF creation omitted + Note over SMO, OCloud: 6 Create VNF + Note over OCloud: Near-RT RIC + Note over SMO, OCloud: 7 Notify Near-RT RIC instantiated + Note over SMO, OCloud: 8 Configure (Near-RT RIC Config) + Note over SMO, OCloud: 9 Create VNF + Note over OCloud: O-CU-CP + Note over SMO, OCloud: 10 Notify O-CU-CP instantiated + Note over SMO: 11 CP_Cfg = Build (Near-RT RIC_Cfg) + Note over SMO: 12 Configure (O-CU-CP_Config) + Note over SMO: Instantiate all req'd O-CU-UP for this O-CU-CP + Note over SMO: loop (foreach O-CU-UP associated with the O-CU-CP) + Note over SMO: 13 Instantiate (O-CU-UP_VNFD) + Note over SMO, OCloud: 14 Create VNF + Note over OCloud: O-CU-UP + Note over SMO, OCloud: 15 Notify O-CU-UP instantiated + Note over SMO: UP_Cfg = Build (Near-RT RIC_cfg, O-CU-CP_Cfg) + Note over SMO: 16 ! + Note over SMO: 17 Configure (O-CU-UP_Cfg) + Note over SMO: 18 deploy xApps + Note over SMO: Near-RT RIC can't subscribe to O-CU-UP msgs until they exist + alt [Near-RT RIC subscribes to O-CU-CP] + Note over SMO, OCloud: 19 «E2» Subscribe + alt [Near-RT RIC subscribes to O-CU-UP] + Note over SMO, OCloud: 20 «E2» Subscribe + Note over SMO: Create all PNF Inventory placeholders + loop (foreach O-DU in O-CU-CP.DUs) + Note over SMO: Inventory_Add(PNF, O-DU, O-DU.ID) + Note over SMO: 21 + loop (foreach O-RU in O-DURUs) + Note over SMO: Inventory_Add(PNF, O-RU, O-RU.ID) + Note over SMO: 22 + end + end + +``` + +Sequence diagram for O-RAN Service Deployment and Configuration. The diagram shows interactions between Personnel (Service Designer, Radio Planner, Field Technician), Service Management & Orchestration Framework (NFO, OAM Functions, Non-RT RIC), O-Cloud (DMS), and O-RAN Components (Near-RT RIC, O-CU-CP, O-CU-UP). The process includes steps for service design, deployment, instantiation, configuration, and subscription management. + +![Sequence diagram for O-RAN Provisioning Use Case. The diagram shows interactions between Personnel (Service Designer, Radio Planner, Field Technician), Service Management & Orchestration Framework (NFO, OAM Functions, Non-RT RIC, DMS), O-Cloud (DMS), and O-RAN Components (Near-RT RIC, O-CU-CP, O-CU-UP, O-DU, O-RU). The process starts with 'PNF Registration and Configuration' (23 Poweron) and 'O-RAN Service Resource PNF Deploy'. Key steps include: 24 Register O-DU (ID), 25 Register PNF Online, 26 DU_Cfg = Generate (Near-RT RIC Cfg, O-CU-CP_Cfg, O-CU-UP), 27 Configure (O-DU_Cfg), 28 Configure xApps for O-DU, 29 «E2» Subscribe, 30 Poweron, 31 Register, 32 Config Change Notification: O-RU Online (O-RU.ID), 33 Register PNF Online, 34 O-DU.Configure O-RU (O-RU.ID, SMO_RUConfig), 35 O-RUConfig = Merge (O-DU.Config, SMO_O-RUConfig), 36 RU.Configure (O-RUConfig), 37 Register O-RU (O-RU.ID), 38 Register PNF Online, 39 O-RU_Config = Build (RU[id], Cfg, O-DU Cfg), 40 Configure (O-RU_Config). The diagram also includes alternative paths for hierarchical and flat SMO management.](ff02d3bcd91720ebb7270e7b1833e525_img.jpg) + +Sequence diagram for O-RAN Provisioning Use Case. The diagram shows interactions between Personnel (Service Designer, Radio Planner, Field Technician), Service Management & Orchestration Framework (NFO, OAM Functions, Non-RT RIC, DMS), O-Cloud (DMS), and O-RAN Components (Near-RT RIC, O-CU-CP, O-CU-UP, O-DU, O-RU). The process starts with 'PNF Registration and Configuration' (23 Poweron) and 'O-RAN Service Resource PNF Deploy'. Key steps include: 24 Register O-DU (ID), 25 Register PNF Online, 26 DU\_Cfg = Generate (Near-RT RIC Cfg, O-CU-CP\_Cfg, O-CU-UP), 27 Configure (O-DU\_Cfg), 28 Configure xApps for O-DU, 29 «E2» Subscribe, 30 Poweron, 31 Register, 32 Config Change Notification: O-RU Online (O-RU.ID), 33 Register PNF Online, 34 O-DU.Configure O-RU (O-RU.ID, SMO\_RUConfig), 35 O-RUConfig = Merge (O-DU.Config, SMO\_O-RUConfig), 36 RU.Configure (O-RUConfig), 37 Register O-RU (O-RU.ID), 38 Register PNF Online, 39 O-RU\_Config = Build (RU[id], Cfg, O-DU Cfg), 40 Configure (O-RU\_Config). The diagram also includes alternative paths for hierarchical and flat SMO management. + +Figure 4.2.1.3-1: O-RAN Provisioning Use Case + +### 4.2.2 O-RAN Measurement Data Collection Use Case + +#### 4.2.2.1 Basic Objective + +In this use case, the Non-RT RIC as the intelligent management center located in Service Management and Orchestration Framework determines that measurement data is needed and interacts with the SMO OAM Functions to collect measurement data from network for AI/ML training/inference/analyzing, and then generate optimization operations in order to improve the end-to-end user service experience and the network performance. + +According to the Service Management and Orchestration Framework, to fulfill the Non-RT RIC requested data collection, the following capability should be supported by the SMO (framework): + +- i The SMO should support the MnS component Type A (defined in 3GPP TS 28.533 [i.4]) generation and the corresponding operation performing (defined in 3GPP TS 28.532 [i.3] and 3GPP TS 28.550 [i.5]), according to the measurement data collection request from the Non-RT RIC +- ii The SMO (framework) should support the MnS component type C (defined in 3GPP TS 28.533 [i.4]) consumption such as the measurement data requested by the Non-RT RIC + +The current use case focuses on the Non-RT RIC requested measurement data collection and consumption, the SMO should generate the PM Job and perform the PM Job control operations accordingly, and the SMO (framework) should support the measurement data consumption by the Non-RT RIC. + +Notes: + +- i* In the O-RAN SMO framework, in order to avoid PM Job conflict, it is suggested that the SMO take the responsibility for generating the PM Job and performing the PM Job control related operations. +- ii* In this use case, the MnS producer of an O-RAN NF decides if the PM Job is acceptable or not, in other words, it is ultimately this MnS producer which decides whether the measurement data collection task can be established or not. + +#### 4.2.2.2 Entities/Resources Involved + +Roles in the PM Job Control related operations: + +- a). The Non-RT RIC: PM Job initiator +- b). The SMO (framework): measurement service component type A consumer +- c). The MnF of the O-RAN NF: measurement service component type A producer + +To fulfill the Non-RT RIC requested measurement data collection by the SMO on the O1/O2 interface, the information related to the collection task shall comply with O1-Interface [2], clause 6.3. + +The measurement data collection information provided by the Non-RT RIC should be converted into a PM Job, and any management operations to the data collection task requested by the Non-RT RIC should be converted into the O1/O2 interface supported PM Job control related management service operations by the SMO. + +Roles in the NotifyFileReady subscribing: + +- a). SMO: management service component type A consumer (consumerReference, as defined in 3GPP TS 28.532 [i.3]) +- b). MnF of the O-RAN NF: producer of notifications + +Roles in the measurement data consumption: + +- a). SMO: management service component type C consumer +- b). MnF of the NFs: producer of streaming data +- c). File Server: storage the measurement data file + +#### 4.2.2.3 Solutions + +##### 4.2.2.3.1 Measurement Data Collection Creation + +Table 4.2.2.3.1-1 shows the procedure of the Non-RT RIC requested measurement data collection task fulfilled by the SMO on the O1/O2 interface. + +**Table 4.2.2.3.1-1: Measurement Data Collection Creation** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | O-RAN Measurement Data Collection | | +| Actors and Roles | [1]. Service Management and Orchestration Framework
[2]. Non-RT RIC
[3]. O-Cloud
[4]. MnF(s) of the O-RAN NFs
[5]. O-RAN NFs, e.g., O-CU, O-DU, O-RU, Near-RT RIC. | | +| Assumptions | None | | +| Pre-conditions | [1]. The SMO and the Non-RT RIC are connected and interact.
[2]. O-RAN components are in running status.
[3]. Secure network connectivity is already available between RAN components. | | +| Begins when | The Non-RT RIC determines that it needs measurement data from the MnF of O-RAN NF (e.g., O-CU-CP) and corresponding O-Cloud infrastructure resources. | | +| Step 1 (M) | The Non-RT RIC provides the information of the measurement data to the SMO | | +| Step 2 (M) | The SMO generates a PM Job as the Non-RT RIC required | | +| Step 3.1 (M) | SMO performs PM Job control management to the MnF via the O1 interface, e.g., Operation createMeasurementJob defined in 3GPP TS 28.550 [i.5] | | +| Step 3.2 (M) | The SMO performs PM Job control management to the O-Cloud over the O2 interface for the infrastructure resources related to the O-CU-CP instance. | | +| Step 4.1 (M) | The MnF responds to the SMO with the PM Job creation result. The PM Job ID should be contained. | | +| Step 4.2 (M) | The O-Cloud responds to the SMO with the PM Job creation result with the PM Job ID. | | +| Step 5.1 (M) | The SMO subscribes to PM Notifications to the MnF instance via the O1 interface. consumerReference defined in 3GPP TS 28.532 [i.3], clause 11.6.1.3 may be the SMO address. | | +| Step 5.2 (M) | The SMO subscribes to O-RAN NF related infrastructure resource instance PM data to the O-Cloud over the O2 interface | | +| Step 6.1 (M) | The MnF provides the result of this operation to the SMO | | +| Step 6.2 (M) | The O-Cloud provides the SMO with the result of the subscription to the O-CU-CP infrastructure resource instance | | +| Step 7 (M) | The SMO provides the result of the measurement data collection establishment to the Non-RT RIC | | +| Ends when | Non-RT RIC has measurement data | | +| Exceptions | None | | +| Post Conditions | The Non-RT RIC initiated measurement data collection has been fulfilled by the SMO; the measured O-RAN MnFs generate measured data as the PM Job required. The subscription to the File Ready notification has been created successfully | | +| Traceability | REQ-M&O-FUN7 | | + +![Sequence diagram for Measurement Data Collection Creation showing interactions between Service Management & Orchestration Framework, O-Cloud, and O-RAN Components.](5c7bac199414e8d7c00e3ee208d8d0e5_img.jpg) + +The diagram illustrates the process of Measurement Data Collection Creation across three main domains: Service Management & Orchestration Framework (SMO), O-Cloud, and O-RAN Components. + +**Participants:** + +- Service Management & Orchestration Framework (SMO):** Contains NFO, OAM Functions, and Non-RT RIC. +- O-Cloud:** Contains DMS. +- O-RAN Components:** Contains O-CU-CP. + +**Sequence of Operations:** + +- Non-RT RIC Request Measurement Data Collection:** Non-RT RIC plans to collect data from O-CU-CP and provides measurement data collection information to SMO. (Step 1: Measurement data collection information) +- SMO Generate PM Job:** SMO generates PM Job(s) (defined in 3GPP TS28.550 and ETSI GS NFV IFA005) according to the collection requirement. (Step 2: Generate PM Job) +- SMO Distribute PM Job:** + - 3.1 Operation createMeasurementJob (to O-CU-CP) + - 3.2 Create PM Job operation (to DMS) +- Create Measurement Job reply:** + - 4.1 Response (from O-CU-CP) + - 4.2 Response (from DMS) +- Operation Subscribe:** + - 5.1 Operation Subscribe to the O-CU-CP + - 5.2 Subscription to the O-Cloud + - 6.1 Response to Subscribe (from O-CU-CP) + - 6.2 Response to Subscription (from DMS) +- SMO Provides Non-RT RIC With the Measurement Data Collection Create Result:** SMO provides the Non-RT RIC with the result of the measurement data collection according to the received PM Job response. (Step 7: Measurement data collection creation result) + +Sequence diagram for Measurement Data Collection Creation showing interactions between Service Management & Orchestration Framework, O-Cloud, and O-RAN Components. + +Figure 4.2.2.3.1-1: Measurement Data Collection Creation + +##### 4.2.2.3.2 Measurement Data File Consumption + +With the performance data file reporting method: + +- The measurement data file may be stored in a file server, and the path should be contained in the NotifyFileReady. +- Once the measurement data file has been prepared, the MnF of the O-CU-CP instance shall report the notification NotifyFileReady to the SMO. + +Table 4.2.2.3.2-1 shows the measurement data file consumption. + +**Table 4.2.2.3.2-1: Measurement Data File Ready Report** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | O-RAN Measurement Data Collection | | +| Actors and Roles | [1]. Service Management and Orchestration Framework
[2]. Non-RT RIC
[3]. O-Cloud
[4]. MnF(s) of the O-RAN NFs
[5]. O-RAN NFs, e.g., O-CU, O-DU, O-RU, Near-RT RIC. | | +| Assumptions | None | | +| Pre-conditions | [1]. The SMO and the Non-RT RIC are connected and interact.
[2]. O-RAN components are in running status.
[3]. Secure network connectivity is already available between RAN components. | | +| Begins when | The SMO shall perform the Operation Subscribe to provide the consumer information to the measurement data producer in the MnF of the NF. The producer in the MnF of the NF shall report the NotifyFileReady once the measurement data file has been prepared | | +| Step 1.1 (M) | The MnF of the O-CU-CP sends the notification NotifyFileReady to the SMO, and it is consumed by the SMO | | +| Step 1.2 (M) | The O-Cloud reports the infrastructure resource measured data file to the SMO | | +| Step 2 (M) | The SMO retrieves the data file from the FileServer, and the collected data is eventually consumed by the Non-RT RIC | | +| Ends when | SMO has collected data | | +| Exceptions | None | | +| Post Conditions | The SMO has received the notification of NotifyFileReady successfully, the data file is consumed by the Non-RT RIC | | +| Traceability | REQ-M&O-FUN7 | | + +![Sequence diagram showing Measurement Data File Consumption. The diagram is divided into three main sections: Service Management & Orchestration Framework (yellow), O-Cloud (teal), and O-RAN Components (pink). The Service Management & Orchestration Framework contains NFO, OAM Functions, and Non-RT RIC. The O-Cloud contains DMS. The O-RAN Components contain O-CU-CP. The sequence of events is: 1. Measurement File Upload To File Server (from OAM Functions to DMS). 2. Notification NotifyFileReady (from DMS to OAM Functions). 3. 1.1 NotifyFileReady (from O-CU-CP to OAM Functions). 4. 1.2 O-Cloud resource measured data (from DMS to OAM Functions). 5. Measurement Data File Transfer (from O-CU-CP to OAM Functions). 6. 2 Data file retrieval (from O-CU-CP to OAM Functions). Annotations include: 'The measurement data has been uploaded to an internal FileServer' and 'The data file and O-Cloud measured data are eventually consumed by the Non-RT RIC'.](750e37a43d9e413da3cf998c777a9ace_img.jpg) + +Sequence diagram showing Measurement Data File Consumption. The diagram is divided into three main sections: Service Management & Orchestration Framework (yellow), O-Cloud (teal), and O-RAN Components (pink). The Service Management & Orchestration Framework contains NFO, OAM Functions, and Non-RT RIC. The O-Cloud contains DMS. The O-RAN Components contain O-CU-CP. The sequence of events is: 1. Measurement File Upload To File Server (from OAM Functions to DMS). 2. Notification NotifyFileReady (from DMS to OAM Functions). 3. 1.1 NotifyFileReady (from O-CU-CP to OAM Functions). 4. 1.2 O-Cloud resource measured data (from DMS to OAM Functions). 5. Measurement Data File Transfer (from O-CU-CP to OAM Functions). 6. 2 Data file retrieval (from O-CU-CP to OAM Functions). Annotations include: 'The measurement data has been uploaded to an internal FileServer' and 'The data file and O-Cloud measured data are eventually consumed by the Non-RT RIC'. + +Figure 4.2.2.3.2-1: Measurement Data File Consumption + +##### 4.2.2.3.3 Measurement Streaming Data Consumption + +With the streaming reporting method: + +- The consumer related information was taken to the producer in the operation of performance data collection creation. +- The performance data streaming service producer shall establish streaming connection(s) to the consumer, in this use case, the MnF of the O-CU-CP acts as the performance data streaming service producer and the SMO as the consumer. +- The MnF of the O-CU-CP shall send measured data on the established connection(s). + +Table 4.2.2.3.3-1 shows the streaming connection(s) establishment and streaming data consumption. + +Table 4.2.2.3.3-1: Measurement Streaming Data Consumption + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | O-RAN Measurement Data Collection | | +| Actors and Roles | [1]. Service Management and Orchestration Framework
[2]. Non-RT RIC
[3]. O-Cloud
[4]. MnF(s) of the O-RAN NFs
[5]. O-RAN NFs, e.g., O-CU, O-DU, O-RU, Near-RT RIC. | | +| Assumptions | None | | +| Pre-conditions | [1]. The SMO and the Non-RT RIC are connected and interact.
[2]. O-RAN components are in running status.
[3]. Secure network connectivity is already available between RAN components. | | +| Begins when | The MnF of the O-CU-CP starts streaming connection(s) establishment to the SMO, and reports the measured data as the PM Job required | | +| Step 1 (M) | The MnF of the O-CU-CP interworks with the SMO to establish streaming connection(s). the connection(s) should not be released until the PM Job is stopped | | +| Step 2.1 (M) | The MnF of the O-CU-CP reports the measured data to the SMO as the PM Job required via the streaming connection(s) | | +| Step 2.2 (O) | The O-Cloud reports the infrastructure resource measured data to the SMO | | +| Ends when | SMO receives measured data | | +| Exceptions | None | | +| Post Conditions | The streaming connection(s) has been established between the MnF of the O-CU-CP and the SMO successfully.
The SMO consumed the measured data successfully | | +| Traceability | REQ-M&O-FUN7 | | + +![Sequence diagram for Measurement Streaming Data Consumption. The diagram shows three main components: Service Management & Orchestration Framework (SMO), O-Cloud, and O-RAN Components. SMO contains NFO, OAM Functions, and Non-RT RIC. O-Cloud contains DMS. O-RAN Components contain O-CU-CP. The process starts with SMO subscribing to O-CU-CP PM Notification as Non-RT RIC required. Then, a Streaming Connection(s) is established successfully. This is followed by Measurement Data Reporting, where the O-CU-CP reports measured data via the streaming connection, and the O-Cloud reports infrastructure resource measured data. Finally, Measurement Data Consumption occurs, where the streaming measurement data is immediately transferred to the Non-RT RIC and correlated with O-Cloud measured data.](a0afbdb0919528ac7726f7747d9f4a4a_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management & Orchestration Framework + participant OCloud as O-Cloud + participant ORAN as O-RAN Components + + Note over SMO: NFO, OAM Functions, Non-RT RIC + Note over OCloud: DMS + Note over ORAN: O-CU-CP + + SMO->>ORAN: SMO subscribe O-CU-CP PM Notification as Non-RT RIC required + Note over SMO,ORAN: Streaming Connection(s) Establishment + SMO->>ORAN: 1 Streaming Connection(s) established successfully + Note over SMO,ORAN: Measurement Data Reporting + ORAN->>OCloud: 2.1 The O-CU-CP reports measured data via streaming connection + OCloud->>SMO: 2.2 The O-Cloud reports the infrastructure resource measured data + Note over SMO,ORAN: Measurement Data Consumption + Note over SMO: The streaming measurement data is immediately transferred to the Non-RT RIC and is correlated with O-Cloud measured data + +``` + +Sequence diagram for Measurement Streaming Data Consumption. The diagram shows three main components: Service Management & Orchestration Framework (SMO), O-Cloud, and O-RAN Components. SMO contains NFO, OAM Functions, and Non-RT RIC. O-Cloud contains DMS. O-RAN Components contain O-CU-CP. The process starts with SMO subscribing to O-CU-CP PM Notification as Non-RT RIC required. Then, a Streaming Connection(s) is established successfully. This is followed by Measurement Data Reporting, where the O-CU-CP reports measured data via the streaming connection, and the O-Cloud reports infrastructure resource measured data. Finally, Measurement Data Consumption occurs, where the streaming measurement data is immediately transferred to the Non-RT RIC and correlated with O-Cloud measured data. + +Figure 4.2.2.3.3-1: Measurement Streaming Data Consumption + +### 4.2.3 O-RAN Configuration + +#### 4.2.3.1 Basic Objective + +The objective of the use case is to provide the ability for the SMO to configure an O-RAN NF and to receive Configuration Management (CM) notifications from the MnF of the O-RAN NF. The Configure O-RAN NF Use Case in this clause shows how O-RAN uses NETCONF as specified in O1-Interface [2] to configure O-RAN NFs. + +#### 4.2.3.2 Entities/Resources Involved + +Roles in the Provisioning Use Case: + +- SMO is the Provisioning MnS Consumer +- MnF of the O-RAN NF is the Provisioning MnS Producer + +#### 4.2.3.3 Configure O-RAN NF Use Case + +The Configure O-RAN NF Use Case illustrates the sequence of NETCONF commands and Provisioning MnS operations, as specified in O1-Interface [2], to configure a NF. + +Before issuing any NETCONF commands, the NETCONF session shall be established. Before changing the configuration of a NF, the appropriate target data store in the associated MnF should be locked to prevent other NETCONF clients, non-NETCONF clients, and human users from interfering with the configuration changes. Note that locking the data store is optional and is at the discretion of the SMO/operator. + +Configuration changes are made using the Create Managed Object Instance operation, Delete Managed Object Instance operation or Modify Managed Object Instance Attributes operation as specified in O1-Interface [2]. If desired, SMO may first read the current NF configuration using the Read Managed Object Instance Attributes operation as specified in O1-Interface [2], before modifying the configuration, in order to ensure that the SMO is synchronized with the current NF configuration. Note that reading the current configuration is optional and is at the discretion of the SMO/operator. If the changes are made in a candidate data store, SMO shall commit the changes to the running data store to make them effective. + +If the SMO wishes to receive CM notifications, SMO shall subscribe to CM notifications using the Subscription Control operation, as specified in O1-Interface [2]. + +Multiple provisioning operations can be executed in sequence, one at a time, under the same lock session. When the SMO has finished sending all the commands that modify the configuration of the data store, the SMO should unlock the target data store so that other clients can make changes. Note that unlocking the data store is optional and is at the discretion of the SMO/operator. + +Finally, if the SMO has no more provisioning operations to perform at this time, SMO can terminate the NETCONF session. Note that terminating the NETCONF session is optional and is at the discretion of the SMO/operator. + +Table 4.2.3.3-1 shows the End-to-End Use Case for the SMO to configure a NF. + +**Table 4.2.3.3-1: Configure NF** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------| +| Goal | Configure NF | | +| Actors and Roles | [1]. Service Management and Orchestration Framework
[2]. MnF of the O-RAN NF
[3]. O-RAN NF | | +| Assumptions | None | | +| Pre-conditions | [1]. Operator has prepared the NF configuration and provided it to the SMO.
[2]. SMO is in an operational state.
[3]. NF is in an operational state.
[4]. SMO is managing the NF via its MnF.
[5]. (Optional) SMO has subscribed to CM Notifications, if desired. | | +| Begins when | SMO decides to configure the NF. | | +| Step 1 (O) | If there is no NETCONF session established, SMO uses the NETCONF Session Establishment operation to establish a NETCONF session to the MnF of an NF. | O1-Interface [2], clause 6.1.81 | +| Step 2 (O) | (Optional) If the target DS is not locked, SMO uses the NETCONF Lock Data Store operation to lock a target data store (DS) on a MnF of the NF. Note that locking the data store is optional and is at the discretion of the SMO/operator. | O1-Interface [2], clause 6.1.10 | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------| +| Step 3 (O) | (Optional) If desired, SMO reads the current NF configuration using the Read Managed Object Instance Attributes operation to ensure that the SMO is synchronized with the current NF configuration before modifying it. Note that reading the current configuration is optional and is at the discretion of the SMO/operator. | O1-Interface [2], clause 6.1.5 | +| Step 4 (M) | SMO configures the MnF data store. Configuration changes are made using the Create Managed Object Instance operation, Delete Managed Object Instance operation or Modify Managed Object Instance Attributes operation. Multiple provisioning operations can be sent in sequence, one at a time, under the same lock session. | O1-Interface [2], clauses 6.1.2, 6.1.3, 6.1.4 | +| Step 5 (O) | If configuration changes were made in the candidate data store, SMO uses the NETCONF Commit operation to commit the changes to the running data store and make them effective. | O1-Interface [2], clause 6.1.12 | +| Step 6 (O) | If SMO has subscribed to CM Notifications, The MnF of the NF sends the appropriate CM notification, using the Notify Managed Object Instance Creation operation, Notify Managed Object Instance Deletion operation, Notify Managed Object Instance Attribute Value Changes operation, or Notify Managed Object Instance Changes operation. | O1-Interface [2], clauses 6.1.6 | +| Step 7 (O) | (Optional) If SMO has successfully completed configuration changes, and if the data store is locked, SMO uses the NETCONF Unlock Data Store operation to unlock a target data store (DS) on the MnF of the NF. Note that unlocking the data store is optional and is at the discretion of the SMO/operator. | O1-Interface [2], clause 6.1.11 | +| Step 8 (O) | If SMO is finished sending NETCONF commands, SMO uses the NETCONF Session Termination operation to terminate a NETCONF session on the MnF of the NF. Note that terminating the NETCONF session is optional and is at the discretion of the SMO/operator. | O1-Interface [2], clause 6.1.9 | +| Ends when | Step 4 or later optional steps complete | | +| Exceptions | See RFC 6241 [i.12] | | +| Post Conditions | NF configuration has been updated in the running DS. | | +| Traceability | O1-Interface [2] REQ-GNC-FUN-1, REQ-GNC-FUN-2, REQ-GNC-FUN-3, REQ-GNC-FUN-4, REQ-GNC-FUN-5, REQ-GNC-FUN-6, REQ-GNC-FUN-7, REQ-GNC-FUN-8, REQ-GNC-FUN-9 | O1-Interface [2], clause 6.1.1 | + +![Sequence diagram for Figure 4.2.3.3-1: Configure NF. The diagram shows interactions between the Service Management & Orchestration Framework (SMO) and the O-RAN Managed Element (ME). The SMO contains OAM Functions, and the ME contains the ME entity. The process starts with OAM Functions in the SMO. An optional step [If NETCONF session is not established] shows «O1» NETCONF Session Establishment. Another optional step shows «O1» NETCONF Lock Data Store. A horizontal line separates this from the next section where the SMO configures the ME. An optional step [If SMO desires] shows «O1» Read MOI Attributes. A loop [until all commands are sent] contains «O1» Delete MOI and/or Create MOI and/or Modify MOI Attributes. Inside the loop, an optional step [If target DB is candidate] shows «O1» NETCONF Commit, and another optional step [If SMO has subscribed to CM notifications] shows «O1» HTTPS CM notification. Another horizontal line follows, labeled 'Configuration changes complete'. Below this, an optional step shows «O1» NETCONF Unlock Data Store, and a final optional step [If SMO has no more NETCONF operations to perform] shows «O1» NETCONF Session Termination. The diagram ends with OAM Functions in the SMO and the ME entity in the ME.](5c5c3969799ce77a583c12ec75ab0f36_img.jpg) + +``` + +sequenceDiagram + participant SMO as Service Management & Orchestration Framework + participant ME as O-RAN Managed Element + participant OAM as OAM Functions + participant ME_entity as ME + + OAM->>ME_entity: «O1» NETCONF Session Establishment + alt [If NETCONF session is not established] + end + OAM->>ME_entity: «O1» NETCONF Lock Data Store + alt opt + end + + SMO-->>ME_entity: SMO configures the ME + + OAM->>ME_entity: «O1» Read MOI Attributes + alt [If SMO desires] + end + + loop [until all commands are sent] + OAM->>ME_entity: «O1» Delete MOI and/or Create MOI and/or Modify MOI Attributes + alt [If target DB is candidate] + OAM->>ME_entity: «O1» NETCONF Commit + end + alt [If SMO has subscribed to CM notifications] + OAM->>ME_entity: «O1» HTTPS CM notification + end + end + + SMO-->>ME_entity: Configuration changes complete + + OAM->>ME_entity: «O1» NETCONF Unlock Data Store + alt opt + end + alt [If SMO has no more NETCONF operations to perform] + OAM->>ME_entity: «O1» NETCONF Session Termination + end + alt opt + end + + OAM + ME_entity + +``` + +Sequence diagram for Figure 4.2.3.3-1: Configure NF. The diagram shows interactions between the Service Management & Orchestration Framework (SMO) and the O-RAN Managed Element (ME). The SMO contains OAM Functions, and the ME contains the ME entity. The process starts with OAM Functions in the SMO. An optional step [If NETCONF session is not established] shows «O1» NETCONF Session Establishment. Another optional step shows «O1» NETCONF Lock Data Store. A horizontal line separates this from the next section where the SMO configures the ME. An optional step [If SMO desires] shows «O1» Read MOI Attributes. A loop [until all commands are sent] contains «O1» Delete MOI and/or Create MOI and/or Modify MOI Attributes. Inside the loop, an optional step [If target DB is candidate] shows «O1» NETCONF Commit, and another optional step [If SMO has subscribed to CM notifications] shows «O1» HTTPS CM notification. Another horizontal line follows, labeled 'Configuration changes complete'. Below this, an optional step shows «O1» NETCONF Unlock Data Store, and a final optional step [If SMO has no more NETCONF operations to perform] shows «O1» NETCONF Session Termination. The diagram ends with OAM Functions in the SMO and the ME entity in the ME. + +Figure 4.2.3.3-1: Configure NF + +### 4.2.4 Use Cases for O-RU Hierarchical Management Architecture Model + +Editor's note: The use cases in this clause have not yet been fully aligned with the format and terminology of the rest of this specification. + +#### 4.2.4.1 O-RU Software Management through O-DU + +##### 4.2.4.1.1 O-RU Software Inventory through O-DU + +Editor's note: The content of this clause has not yet been aligned with O1-Interface [2]. + +###### 4.2.4.1.1.1 Description + +The SMO retrieves the software inventory information of an O-RU. + +###### 4.2.4.1.1.2 Procedures + +###### Precondition: + +- O-DU has retrieved the software inventory information of connected O-RUs at startup. + +![Sequence diagram for Software Inventory procedure. The diagram shows three entities: SMO (PNF Software MnS Consumer), O-DU (PNF Software MnS Producer), and O-RU. The SMO and O-DU are connected by a dashed line. The O-DU and O-RU are connected by a dashed line. A yellow box labeled 'Retrieve Software Inventory Information of O-RU' is positioned above the O-DU and O-RU connection. The sequence of messages is: [1] Establish NETCONF Session (SMO to O-DU), [2] NETCONF (SMO to O-DU), [3] NETCONF (O-DU to SMO), and [4] Terminate NETCONF Session (SMO to O-DU).](4b54d3c9163cf1d4f8db8b55169b96cf_img.jpg) + +**Software Inventory** + +``` + +sequenceDiagram + participant SMO as SMO +(PNF Software MnS Consumer) + participant ODU as O-DU +(PNF Software MnS Producer) + participant ORU as O-RU + + SMO-->>ODU: [1] Establish NETCONF Session + SMO->>ODU: [2] NETCONF + ODU-->>SMO: [3] NETCONF + SMO-->>ODU: [4] Terminate NETCONF Session + +``` + +Sequence diagram for Software Inventory procedure. The diagram shows three entities: SMO (PNF Software MnS Consumer), O-DU (PNF Software MnS Producer), and O-RU. The SMO and O-DU are connected by a dashed line. The O-DU and O-RU are connected by a dashed line. A yellow box labeled 'Retrieve Software Inventory Information of O-RU' is positioned above the O-DU and O-RU connection. The sequence of messages is: [1] Establish NETCONF Session (SMO to O-DU), [2] NETCONF (SMO to O-DU), [3] NETCONF (O-DU to SMO), and [4] Terminate NETCONF Session (SMO to O-DU). + +**Figure 4.2.4.1.1.2-1: Software Inventory** + +1. SMO establishes NETCONF session with O-DU. +2. O-DU receives NETCONF from SMO where software aggregated model is indicated to retrieve information of software slot of O-RU. +3. O-DU returns requested data in NETCONF response. +4. SMO terminates NETCONF session with O-DU. + +##### 4.2.4.1.2 O-RU Software Download and Install through O-DU + +###### 4.2.4.1.2.1 Description + +The SMO triggers the software download to a target O-RU through the managing O-DU as described in O1-Interface [2], clause 6.8.3. + +After software download, O-DU triggers software install on the O-RU as described in OFH M-Plane [1], clause 8.6. + +###### 4.2.4.1.2.2 Procedures + +Editor's note: The content of this clause has not yet been aligned with O1-Interface [2]. + +![Sequence diagram for Software Download showing interactions between SMO, O-DU, Software Server, and O-RU. The diagram includes steps for establishing a NETCONF session, sending a software download request, validating the request, and then two alternative paths for downloading the software: direct (O-DU to O-RU) and indirect (O-DU to Software Server to O-RU).](25de4caad63f39aa96ae4c50df78accf_img.jpg) + +**Software Download** + +``` + +sequenceDiagram + participant SMO as SMO +(PNF Software MnS Consumer) + participant ODU as O-DU +(PNF Software MnS Producer) + participant SS as Software Server + participant ORU as O-RU + + SMO->>ODU: [1] Establish NETCONF Session + SMO->>ODU: NETCONF +[2] + + Note over ODU: Validate Request + ODU->>SMO: [3] NETCONF + SMO->>ODU: [4] Terminate NETCONF Session + + alt [direct case] + ODU->>ORU: [5] + ORU->>ODU: [6] + ORU->>SS: [7] «SFTP» file download + else [indirect case] + ODU->>SS: [8] «FTPeS or SFTP» file download + Note over ODU: manifest file check + ODU->>ORU: [9] + ORU->>ODU: [10] + ORU->>SS: [11] «SFTP» file download + end + + ODU->>SS: [12] + ODU->>ORU: [13] + ORU->>ODU: [14] + ODU->>SS: [15] + ODU->>SMO: [16] «HTTP/TLS» downloadFile Event + +``` + +Sequence diagram for Software Download showing interactions between SMO, O-DU, Software Server, and O-RU. The diagram includes steps for establishing a NETCONF session, sending a software download request, validating the request, and then two alternative paths for downloading the software: direct (O-DU to O-RU) and indirect (O-DU to Software Server to O-RU). + +**Figure 4.2.4.1.2.2-1: Software Download** + +1. SMO establishes NETCONF session with O-DU. +2. SMO sends NETCONF with ru-instance-id to trigger a download of the software and to identify the target O-RU. + - a. O-DU validates the request. +3. O-DU returns NETCONF . +4. SMO terminates NETCONF session with O-DU. +- Alternative 1: O-RU directly downloads the software package from software server. + 5. O-DU sends toward O-RU with remote-file-path. + 6. O-RU returns . + 7. O-RU downloads the software package. +- Alternative 2: O-RU indirectly downloads the software package from software server. + 8. O-DU downloads software package of O-RU from software server and temporarily stores in the storage on itself. NOTE: storing SW package in O-DU may be removed after step 14. + - b. O-DU decides whether download is needed or not by comparing manifest file and information of software slot. + 9. O-DU sends toward O-RU with remote-file-path. + 10. O-RU returns . + 11. O-RU downloads the software package. + +12. O-RU sends to notify the result of download process. +13. O-DU sends to perform the software install for O-RU. O-DU selects an install slot based on O1-Interface [2]. +14. O-RU returns . +15. O-RU sends to notify the result of install process. +16. When download operation is completed, O-DU sends download-event NETCONF downloadFile notification to SMO with the final status of the download (success or the reason for failure). + +##### 4.2.4.1.3 O-RU Software Activation through O-DU + +Editor's note: The content of this clause has not yet been aligned with O1-Interface [2]. + +###### 4.2.4.1.3.1 Description + +O-DU receives a software activation trigger from the SMO for an O-RU, and O-DU executes the software activation mechanism on that O-RU. + +###### 4.2.4.1.3.2 Procedures + +![Sequence diagram for Software Activate procedure. The diagram shows interactions between SMO (PNF Software MnS Consumer), O-DU (PNF Software MnS Producer), and O-RU.](42e02540f640bf063e28cc29863446fa_img.jpg) + +**Software Activate** + +``` + +sequenceDiagram + participant SMO as SMO (PNF Software MnS Consumer) + participant ODU as O-DU (PNF Software MnS Producer) + participant ORU as O-RU + + SMO->>ODU: [1] Establish NETCONF Session + SMO->>ODU: [2] NETCONF
+ Note over ODU: Validate request + ODU->>SMO: [3] NETCONF + SMO->>ODU: [4] Terminate NETCONF Session + ODU->>ORU: [5] NETCONF + ORU->>ODU: [6] NETCONF + ORU->>ODU: [7] NETCONF + ODU->>ORU: [8] NETCONF + ORU->>ODU: [9] NETCONF + Note over ORU: Reset + ODU->>SMO: [10] «HTTP/TLS» softwareActivate Event + +``` + +Sequence diagram for Software Activate procedure. The diagram shows interactions between SMO (PNF Software MnS Consumer), O-DU (PNF Software MnS Producer), and O-RU. + +Figure 4.2.4.1.3.2-1: Software Activate + +1. SMO establishes NETCONF session with O-DU. +2. SMO sends NETCONF with ru-instance-id to trigger an activation of the software slot on O-RU. + - a. O-DU validates the request. +3. O-DU returns status to the SMO in the NETCONF response. +4. SMO terminates NETCONF session with O-DU. +5. O-DU sends to activate the software slot on O-RU. The most recently used slot to install is selected. + +6. O-RU returns status into . +7. O-DU receives . +8. O-DU sends toward O-RU to apply the newly installed and activated software. +9. O-RU returns . + - a. O-RU starts reset process. +10. When O-DU retrieves software inventory information of all reset O-RU in the startup, O-DU sends a softwareActivate notification to SMO with the final status of the software activate and O-RU reset results. + +#### 4.2.4.2 O-RU Performance Assurance Management through O-DU + +Editor's note: The content of this clause has not yet been aligned with O1-Interface [2]. + +##### 4.2.4.2.1 O-RU Performance Data File Reporting through O-DU + +The measured result file created by O-RU will be periodically uploaded to O-DU's internal storage aligned with the OFH M-Plane [1], clause 10.3. O-DU will handle the file as described in O1-Interface [2], clause 6.3.1. + +Alternatively, the measured result file created by O-RU will be forwarded to the FTP server configured by O-DU. In this case, the Performance Assurance MnS Consumer shall provide the remote-SFTP-upload-path and its credentials to O-RU, so that it can upload the PM data file directly. + +##### 4.2.4.2.2 O-RU Performance Assurance Control through O-DU + +The performance measurements to be collected in O-RU are controlled by SMO via O-DU as described in O1-Interface [2], clause 6.3.3. + +#### 4.2.4.3 O-RU Alarm Management through O-DU + +Editor's note: The content of this clause has not yet been aligned with O1-Interface [2]. + +##### 4.2.4.3.1 Description + +In the hierarchical management model, O-DU is responsible for managing AlarmRecords in the AlarmList, including both O-DU alarms and O-RU alarms. + +O-DU receives a NETCONF based alarm notification from the O-RU, converts the NETCONF based alarm notification to an O-RAN fault notification, updates AlarmRecords and sends the O-RAN fault notification to SMO. + +O-DU alarms and O-RU alarms may have the same alarm-id; in this case, they are distinguished using nfcNamingCode in the VES common event header. + +##### 4.2.4.3.2 Procedures + +![Sequence diagram showing the operation to merge O-RU Alarms by O-DU. The diagram involves three entities: O-RU, O-DU, and SMO. O-RU sends a notification to O-DU, which then forwards it to SMO.](9f77c8e8a3f647adf0cd8fdb174ae2c1_img.jpg) + +``` + +sequenceDiagram + participant O_RU as O-RU + participant O_DU as O-DU + participant SMO as SMO + + Note over O_RU: RU detects a change of state in one of the alarms in the active-alarm-list corresponding to the filter settings established in the subscription. + O_RU->>O_DU: [1] +.. + + + Note over O_DU: O-DU converts NETCONF based alarm notification to O-RAN fault notification, updates alarm records. + O_DU->>SMO: [2] O-RU alarm event delivery using O-RAN fault notification + +``` + +Sequence diagram showing the operation to merge O-RU Alarms by O-DU. The diagram involves three entities: O-RU, O-DU, and SMO. O-RU sends a notification to O-DU, which then forwards it to SMO. + +Figure 4.2.4.3.2-1: Operation to merge O-RU Alarms by O-DU + +#### 4.2.4.4 O-RU Provisioning Management through O-DU + +##### 4.2.4.4.1 O-RU Configuration through O-DU + +Configuration steps for the hierarchical management model are as follows: + +1. SMO configures O-DU as described in O1-Interface [2], clause 6.1. +2. O-DU configures O-RU as described in the OFH M-Plane [1]. + +##### 4.2.4.4.2 Cell Configuration and Activation in Hierarchical Management Architecture Model + +Editor's note: The content of this clause has not yet been aligned with O1-Interface [2]. + +###### 4.2.4.4.2.1 Description + +After cell configuration on the O-DU, followed by carrier configuration on the O-RU, SMO may activate cells. + +###### 4.2.4.4.2.2 Procedures + +Editor's note: The content of this clause needs to be reviewed and potentially revised to ensure that the F1 message content is technically valid. + +![Sequence diagram for Cell activation procedure showing interactions between O-RU, O-DU, O-CU, and SMO.](ffc23dcb72df118c8ca591af09bf17d6_img.jpg) + +``` + +sequenceDiagram + participant O-RU + participant O-DU + participant O-CU + participant SMO + + par + O-DU->>O-CU: [1] Cell configuration + O-CU->>O-DU: [2] Carrier configuration + O-DU->>O-CU: [3] LOCKED + O-DU->>O-CU: [4] LOCKED + O-DU->>O-CU: [5] ENABLED + O-DU->>O-CU: [6] UNLOCKED + and + F1_Startup_step["F1 Startup step +See AnnexA.1 TS.28.541"] + O-DU->>O-CU: [7] F1 setup request + O-CU->>O-DU: [8] F1 setup response + O-DU->>O-CU: [9] gNB-CU configuration update + O-CU->>O-DU: [10] gNB-CU configuration update ACK + end + + O-DU->>O-RU: [11] + +ACTIVE + + + +``` + +The diagram illustrates the cell activation procedure. It shows the interaction between O-RU, O-DU, O-CU, and SMO. The procedure is divided into two main parts: a parallel block for initial configuration and a separate block for the F1 startup step. The parallel block includes steps [1] through [6], where O-DU sends configuration and state information to O-CU, and O-CU sends carrier configuration back to O-DU. The F1 startup step block includes steps [7] through [10], where O-DU sends an F1 setup request to O-CU, O-CU responds with an F1 setup response, O-DU sends a gNB-CU configuration update to O-CU, and O-CU responds with a gNB-CU configuration update ACK. Finally, O-DU sends an RPC message to O-RU, containing edit-config, active state, and edit-config end tags. + +Sequence diagram for Cell activation procedure showing interactions between O-RU, O-DU, O-CU, and SMO. + +Figure 4.2.4.4.2.2-1: Cell activation procedure + +##### 4.2.4.4.3 Forwarding Configuration Change Notifications from O-RU through O-DU + +Editor's note: The content of this clause has not yet been aligned with O1-Interface [2]. + +Editor's note: The content of this clause currently has a dependency to the O-RU aggregated model and, due to this, needs to be reviewed and potentially revised. + +###### 4.2.4.4.3.1 Description + +The O-DU is responsible for presenting O-RU configuration to SMO. The SMO is responsible for subscribing to any parameters of interest using the subscription mechanism as described in O1-Interface [2], clause 6.1.7. + +Once the SMO has subscribed, the SMO will receive a notification for each value change of the parameter(s) from the O-DU. + +###### 4.2.4.4.3.2 Procedures + +![Sequence diagram for Figure 4.2.4.4.3.2-1: Notification to the SMO preceded by the O-RU notification. The diagram shows three lifelines: SMO, O-DU, and O-RU. A yellow note at the top states 'SMO is already subscribed to O-DU'. An arrow labeled 'notification' goes from O-RU to O-DU. A text block 'Change of aggregated model parameters for the O-RU' is on the O-DU lifeline. A yellow note below states 'Parameter of interest of SMO has changed'. An arrow labeled 'notification' goes from O-DU to SMO.](a0fa1fe97028ce426ccac396ca4d5f18_img.jpg) + +``` + +sequenceDiagram + participant SMO + participant O-DU + participant O-RU + Note over SMO,O-DU: SMO is already subscribed to O-DU + O-RU->>O-DU: notification + Note over O-DU: Change of aggregated model parameters for the O-RU + Note over SMO,O-DU: Parameter of interest of SMO has changed + O-DU->>SMO: notification + +``` + +Sequence diagram for Figure 4.2.4.4.3.2-1: Notification to the SMO preceded by the O-RU notification. The diagram shows three lifelines: SMO, O-DU, and O-RU. A yellow note at the top states 'SMO is already subscribed to O-DU'. An arrow labeled 'notification' goes from O-RU to O-DU. A text block 'Change of aggregated model parameters for the O-RU' is on the O-DU lifeline. A yellow note below states 'Parameter of interest of SMO has changed'. An arrow labeled 'notification' goes from O-DU to SMO. + +Figure 4.2.4.4.3.2-1: Notification to the SMO preceded by the O-RU notification + +![Sequence diagram for Figure 4.2.4.4.3.2-2: Notification to the SMO preceded by the O-DU operation. The diagram shows three lifelines: SMO, O-DU, and O-RU. A yellow note at the top states 'SMO is already subscribed to O-DU'. On the O-DU lifeline, there is a sequence of messages: , , ..., , and . An arrow goes from O-DU to O-RU. On the O-RU lifeline, there is a sequence of messages: , , ..., , and . An arrow goes from O-RU to O-DU. A text block 'Change of aggregated model parameters for the O-RU' is on the O-DU lifeline. A yellow note below states 'Parameter of interest of SMO has changed'. An arrow labeled 'notification' goes from O-DU to SMO.](e5e54902ca1a9d818cf12df7adee3f22_img.jpg) + +``` + +sequenceDiagram + participant SMO + participant O-DU + participant O-RU + Note over SMO,O-DU: SMO is already subscribed to O-DU + Note over O-DU: + +... + + + O-DU->>O-RU: + Note over O-RU: + +... + + + O-RU->>O-DU: + Note over O-DU: Change of aggregated model parameters for the O-RU + Note over SMO,O-DU: Parameter of interest of SMO has changed + O-DU->>SMO: notification + +``` + +Sequence diagram for Figure 4.2.4.4.3.2-2: Notification to the SMO preceded by the O-DU operation. The diagram shows three lifelines: SMO, O-DU, and O-RU. A yellow note at the top states 'SMO is already subscribed to O-DU'. On the O-DU lifeline, there is a sequence of messages: , , ..., , and . An arrow goes from O-DU to O-RU. On the O-RU lifeline, there is a sequence of messages: , , ..., , and . An arrow goes from O-RU to O-DU. A text block 'Change of aggregated model parameters for the O-RU' is on the O-DU lifeline. A yellow note below states 'Parameter of interest of SMO has changed'. An arrow labeled 'notification' goes from O-DU to SMO. + +Figure 4.2.4.4.3.2-2: Notification to the SMO preceded by the O-DU operation + +### 4.2.5 Network Energy Saving Use Cases + +#### 4.2.5.1 RF Channel Reconfiguration + +##### 4.2.5.1.1 TRX Control + +###### 4.2.5.1.1.1 Basic Objective + +The objective of this use case is to illustrate an operator's use of TRX Control-based energy savings via corresponding policy/configuration by the SMO over the O1 interface. + +###### 4.2.5.1.1.2 Entities/Resources Involved + +Roles in the TRX Control use case: + +- a) SMO playing the role of Provisioning MnS Consumer +- b) O-DU playing the role of Provisioning MnS Producer +- c) O-RU + +###### 4.2.5.1.1.3 Description + +The use case illustrates the interactions between the involved entities in the context of TRX Control-based energy savings for the O-RU. + +Table 4.2.5.1.1.3-1 shows the SMO providing policy/configuration details to the O-DU for implementing TRX Control-based energy saving in O-RU. + +**Table 4.2.5.1.1.3-1: TRX Control** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------| +| Goal | Provide TRX Control-based energy savings policy/configuration to the O-DU. | | +| Actors and Roles | [1]. Service Management and Orchestration Framework (SMO) as the Provisioning MnS Consumer
[2]. O-DU as the Provisioning MnS Producer
[3]. O-RU | | +| Assumptions | None | | +| Pre-conditions | [1]. Connection is successfully established between MnS Producer of O-DU and MnS Consumer via O1 interface.
[2]. Connection is successfully established between O-DU and O-RU via Open Fronthaul M-Plane.
[3]. In hierarchical deployment, O-DU is aware of the TRX Control-related O-RU capabilities.
[4]. MnS Consumer has subscribed to CM Notifications. | | +| Begins when | SMO decides to provide the policy to O-DU for the TRX Control-based energy savings. | | +| Step 0 | MnS Consumer retrieves TRX Control-related capabilities from MnS Producer as below: | a. clause 4.2.3.3

b. clause 4.2.4.4.1 | + +| | | | +|-------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------| +| |

a. MnS Consumer retrieves TRX Control-related capabilities from MnS Producer of O-DU via O1 interface.

b. Hierarchical architecture: MnS Consumer retrieves TRX Control-related capabilities of the O-RU from the MnS Producer of O-DU via O1 interface.

c. Hybrid architecture: MnS Consumer retrieves TRX Control-related capabilities from O-RU via Open Fronthaul M-Plane.

| c. OFH M-Plane [1], clause 20.3.2.2 | +| Step 1 (M) | MnS Consumer provides TRX Control-based energy saving-related policy/configuration details to the MnS Producer. | clause 4.2.3.3 | +| Step 2 (M) | The O-DU examines the condition(s) provided in configuration/policy related to TRX Control. | | +| Step 3.1 (M) | O-DU monitors relevant data and watches for the thresholds configured/provided in the policy of Step 1 to be satisfied. | | +| Step 3.2 (M) | Once conditions are satisfied, the O-DU communicates appropriate antenna mask values and sleep mode to the O-RU using Open Fronthaul C-Plane message. See NOTE 1. | OFH CUS-Plane [i.14], clauses 16.1, 16.2 | +| Step 3.3 (M) | The O-RU processes the Open Fronthaul C-Plane message and activates corresponding TRX Control configuration. | | +| Step 3.4 (O) | O-RU sends the ACK/NACK message to O-DU via Open Fronthaul C-Plane. | OFH CUS-Plane [i.14], clause 16.1 | +| Step 4.1 (O) | MnS Consumer needs to be made aware of execution of this step via notification. | | +| Step 4.2 (O) | MnS Consumer analyses the policy status. | | +| Step 5.1 (O) | MnS Consumer needs to be made aware of execution of this step via counter. | clause 4.2.2.3.2 | +| Step 5.2 (O) | MnS Consumer analyses the PM data. | | +| Step 6 (O) | MnS Consumer removes some of the policies. | clause 4.2.3.3 | +| Step 7 (O) | MnS Consumer needs to be made aware of the policy status via notification. | clause 4.2.3.3 | +| Ends when | MnS Consumer removes all TRX Control-based energy saving related policy/configuration details from the MnS Producer. | | +| Exceptions | None | | +| Post Conditions | MnS Consumer is informed about the result of TRX Control based energy saving related actions. | | +| Traceability | Editor's note: Requirements to be added later. | | +| NOTE 1: See OFH M-Plane [1], clause 20.3.2.5 for more details on the interaction between TRX Control and Advanced Sleep Mode. | | | + +![Sequence diagram showing the TRX Control based Network energy saving implementation using O1 interface. The diagram involves three main entities: MnS Consumer (yellow background), MnS Producer (O-DU) (pink background), and O-RU (pink background). The process starts with the MnS Consumer retrieving capabilities from the O-DU and O-RU. It then enters a loop for policy processing, where the MnS Producer provides policy details, examines conditions, monitors data, and sends antenna mask and sleep mode information to the O-RU. The O-RU then activates the specific antenna mask and sleep mode. Finally, the MnS Consumer notifies the policy utilization status, analyzes the status, and reports back to the MnS Producer, who then removes the policy and notifies the status.](0cd45ba3e434d7c0f76a99c8344cbabe_img.jpg) + +**Network Energy Saving - RF Channel Reconfiguration (TRX Control Activation process)** + +``` + +sequenceDiagram + participant MnS_Consumer as MnS Consumer + participant MnS_Producer as MnS Producer (O-DU) + participant O_RU as O-RU + + MnS_Consumer->>MnS_Producer: 0.a «O1» Retrieves capabilities of the O-DU + alt [MnS Consumer retrieves TRX Control related capabilities - Hierarchical Architecture] + MnS_Consumer->>O_RU: 0.b «O1» Retrieves capabilities of the O-RU + else [MnS Consumer retrieves TRX Control related capabilities - Hybrid Architecture] + MnS_Consumer->>O_RU: 0.c «Open FH M-Plane» Retrieves capabilities of the O-RU + end + + loop [TRX Control based Energy Saving process] + MnS_Consumer->>MnS_Producer: 1 «O1» Provide policy/configuration details + loop [Policy processing] + MnS_Producer->>MnS_Producer: 2 Examine the conditions + MnS_Producer->>MnS_Producer: 1 3.1 Monitors/collect relevant data + MnS_Producer->>O_RU: 3.2 «Open FH C-Plane» Sends antenna mask and sleep mode to be activated + O_RU->>O_RU: 3.3 Activates the specific antenna mask and sleep mode + O_RU->>MnS_Producer: 3.4 «Open FH C-Plane» Receives ACK/NACK message + end + end + + alt [ ] + alt [ ] + O_RU->>MnS_Producer: 4.1 «O1» Notify the policy utilization status + MnS_Producer->>MnS_Producer: 4.2 Analyze policy status + end + MnS_Producer->>MnS_Consumer: 5.1 «O1» Regular PM reporting + MnS_Consumer->>MnS_Consumer: 5.2 Analyze PM data + end + + alt [ ] + MnS_Producer->>MnS_Consumer: 6 «O1» Policy removal + MnS_Consumer->>MnS_Producer: 7 «O1» Notify the policy removal status + end + +``` + +Sequence diagram showing the TRX Control based Network energy saving implementation using O1 interface. The diagram involves three main entities: MnS Consumer (yellow background), MnS Producer (O-DU) (pink background), and O-RU (pink background). The process starts with the MnS Consumer retrieving capabilities from the O-DU and O-RU. It then enters a loop for policy processing, where the MnS Producer provides policy details, examines conditions, monitors data, and sends antenna mask and sleep mode information to the O-RU. The O-RU then activates the specific antenna mask and sleep mode. Finally, the MnS Consumer notifies the policy utilization status, analyzes the status, and reports back to the MnS Producer, who then removes the policy and notifies the status. + +**Figure 4.2.5.1.1.3-1: TRX Control based Network energy saving implementation using O1 interface.** + +#### 4.2.5.2 Advanced Sleep Mode + +##### 4.2.5.2.1 Basic Objective + +The objective of this use case is to illustrate an operator's use of Advanced Sleep Mode-based energy savings via corresponding policy/configuration by the SMO over O1 interface. + +##### 4.2.5.2.2 Entities/Resources Involved + +Roles in the Advanced Sleep Mode use case: + +- SMO playing the role of Provisioning MnS Consumer +- O-DU playing the role of Provisioning MnS Producer +- O-RU + +##### 4.2.5.2.3 Description + +The use case illustrates interactions between the involved entities in the context of Advanced Sleep Mode-based energy savings for the O-RU. + +Table 4.2.5.2.3-1 shows the SMO providing policy/configuration details to the O-DU for implementing Advanced Sleep Mode-based energy saving in O-RU. + +**Table 4.2.5.2.3-1: Advanced Sleep Mode** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------| +| Goal | Provide Advanced Sleep Mode-based energy savings policy/configuration to the O-DU. | | +| Actors and Roles | [1]. Service Management and Orchestration Framework (SMO) as the Provisioning MnS Consumer
[2]. O-DU as the Provisioning MnS Producer
[3]. O-RU | | +| Assumptions | None | | +| Pre-conditions | [1]. Connection is successfully established between MnS Producer of O-DU and MnS Consumer via O1 interface.
[2]. Connection is successfully established between O-DU and O-RU via Open Fronthaul M-Plane.
[3]. In hierarchical deployment, O-DU is aware of the Advanced Sleep Mode-related O-RU capabilities.
[4]. MnS Consumer has subscribed to CM Notifications. | | +| Begins when | SMO decides to provide the policy to O-DU for the Advanced Sleep Mode-based energy savings. | | +| Step 0 | MnS Consumer retrieves Advanced Sleep Mode-related capabilities from MnS Producer as below:

a. MnS Consumer retrieves Advanced Sleep Mode-related capabilities from MnS Producer of O-DU via O1 interface.

b. Hierarchical architecture: MnS Consumer retrieves Advanced Sleep Mode-related capabilities of the O-RU from the MnS Producer of O-DU via O1 interface.

c. Hybrid architecture: MnS Consumer retrieves Advanced Sleep Mode-related capabilities from O-RU via Open Fronthaul M-Plane. | a. clause 4.2.3.3
b. clause 4.2.4.4.1
c. OFH M-Plane [1], clause 20.4.1 | +| Step 1 (M) | MnS Consumer provides Advanced Sleep Mode-based energy saving related policy/configuration details to the MnS Producer. | clause 4.2.3.3 | +| Step 2 (M) | The O-DU examines the condition(s) provided in configuration/policy related to Advanced Sleep Mode. | | +| Step 3.1 (M) | O-DU monitors relevant data and watches for the thresholds configured/provided in the policy of Step 1 to be satisfied. | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|---------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------| +| Step 3.2 (O) | Once conditions are satisfied, the O-DU activates or deactivates the appropriate Advanced Sleep Mode in O-RU using Open Fronthaul C-Plane message. For Advanced Sleep Mode deactivation, optionally, an Open Fronthaul M-Plane message can be used if deactivation via Open Fronthaul C-Plane is not available. See NOTE 1. | OFH CUS-Plane [i.14], clauses 16.1, 16.3, OFH M-Plane [1], clause 20.4.2 | +| Step 3.3 (O) | The O-RU processes the Open Fronthaul C-Plane or Open Fronthaul M-Plane message and activates/deactivates the corresponding Advanced Sleep Mode. | | +| Step 3.4 (O) | O-RU sends the ACK/NACK message to O-DU via Open Fronthaul C-Plane. | OFH CUS-Plane [i.14], clause 16.1 | +| Step 4.1 (O) | MnS Consumer needs to be made aware of execution of this step via notification. | | +| Step 4.2 (O) | MnS Consumer analyses the policy status. | | +| Step 5.1 (O) | MnS Consumer needs to be made aware of execution of this step via counter. | clause 4.2.2.3.2 | +| Step 5.2 (O) | MnS Consumer analyses the PM data. | | +| Step 6 (O) | MnS Consumer removes some of the policies. | clause 4.2.3.3 | +| Step 7 (O) | MnS Consumer needs to be made aware of the policy status via notification. | clause 4.2.3.3 | +| Ends when | MnS Consumer removes all Advanced Sleep Mode-based energy saving related policy/configuration details from the MnS Producer. | | +| Exceptions | None | | +| Post Conditions | None | | +| Traceability | Editor's note: Requirements to be added later. | | +| NOTE 1: See OFH M-Plane [1], clause 20.3.2.5 for more details on interaction between TRX Control and Advanced Sleep Mode. | | | + +![Sequence diagram showing the Advanced Sleep Mode Activation process between MnS Consumer and O-RAN NF (MnS Producer (O-DU) and O-RU). The process includes capability retrieval, policy provision, processing, and reporting.](5161f7b155f9777fbd1c86b540a031e0_img.jpg) + +Network Energy Saving - Advanced Sleep Mode Activation process) + +``` + +sequenceDiagram + participant MnS_Consumer as MnS Consumer + participant MnS_Producer as MnS Producer (O-DU) + participant O_RU as O-RU + + alt [MnS Consumer retrieves Advanced Sleep Mode related capabilities - Hierarchical Architecture] + MnS_Consumer->>MnS_Producer: 0.a «O1» Retrieves capabilities of the O-DU + end + alt [MnS Consumer retrieves Advanced Sleep Mode related capabilities - Hybrid Architecture] + MnS_Consumer->>O_RU: 0.b «O1» Retrieves capabilities of the O-RU + end + alt [MnS Consumer retrieves Advanced Sleep Mode related capabilities - Hybrid Architecture] + MnS_Consumer->>O_RU: 0.c «Open FH M-Plane» Retrieves capabilities of the O-RU + end + + loop [Advanced Sleep Mode based Energy Saving process] + MnS_Consumer->>MnS_Producer: 1 «O1» Provide policy/configuration details + loop [Policy processing] + MnS_Producer->>O_RU: 2 Examine the conditions + O_RU-->>MnS_Producer: 3.1 Monitors/collect relevant data + end + opt + ref + MnS_Producer->>O_RU: 3.2 Advanced Sleep Mode activation/deactivation + ref + O_RU->>MnS_Producer: 3.3 Activates/deactivates the specific Advanced Sleep Mode + end + end + end + opt + ref + MnS_Producer->>O_RU: 3.4 «Open FH C-Plane» Receives ACK/NACK message + end + end + end + + alt + alt + O_RU->>MnS_Producer: 4.1 «O1» Notify the policy utilization status + MnS_Producer->>MnS_Consumer: 4.2 Analyze policy status + end + alt + O_RU->>MnS_Producer: 5.1 «O1» Regular PM reporting + MnS_Producer->>MnS_Consumer: 5.2 Analyze PM data + end + end + opt + MnS_Producer->>O_RU: 6 «O1» Policy removal + O_RU->>MnS_Producer: 7 «O1» Notify the policy removal status + end + +``` + +Sequence diagram showing the Advanced Sleep Mode Activation process between MnS Consumer and O-RAN NF (MnS Producer (O-DU) and O-RU). The process includes capability retrieval, policy provision, processing, and reporting. + +Figure 4.2.5.2.3-1: Advanced Sleep Mode based Network energy saving implementation using O1 interface. + +### 4.2.6 Policy management + +#### 4.2.6.1 Overview + +The policy characteristics guide the configuration of NF-specific parameters for optimization and other feature implementation. + +O-RAN NEs/NFs report measurement metrics and KPI data to SMO. SMO derives and sends policies for O-RAN NEs/NFs via the O1 interface to achieve specific objectives related to use cases. The policy can be used by network functions (e.g., O-CU-CP and O-DU) to achieve the objective defined in the policy. In this process, O-DU can also influence the O-RU's functionality to achieve various optimizations. Policies may include performance targets, rules/conditions, and associated configurations. + +#### 4.2.6.2 Basic Objective + +The objective of this use case is to enable an operator through SMO to manage policies using the policy management of the MnF of the NF (e.g., O-CU-CP, O-DU) acting as MnS producer, to support various optimization use cases for that NF via the O1 interface. + +#### 4.2.6.3 Entities/Resources Involved + +Entities that are involved in the policy management use case: + +- a) SMO is the MnS Consumer and policy-defining entity +- b) MnF of the NF as MnS Producer +- c) NF as a policy-enforcing entity + +#### 4.2.6.4 Description + +The use case demonstrates the interactions between the involved entities within the context of Policy Management. + +Table 4.2.6.4-1 illustrates how the SMO provides and manages policies in the MnS Producer, which can be utilized for implementing various optimization features (e.g., Network Energy Saving). + +**Table 4.2.6.4-1: Policy management** + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | The SMO manages policies for the MnF of the NF (e.g., O-CU-CP, O-DU) acting as MnS producer to support various optimization features. | | +| Actors and Roles | [1]. SMO is the MnS Consumer and policy defining entity
[2]. MnF of the NF as MnS Producer
[3]. NF as a policy enforcing entity | | +| Assumptions | None | | +| Pre-conditions | [1]. Connection is successfully established between MnS Producer and MnS Consumer via O1 interface.
[2]. MnS Consumer has subscribed to MnS Producers for the CM Notifications. | | +| Begins when | SMO decides to provide policies to the O-DU and manages them to support various optimization features. | | +| Step 0 | The MnS Consumer retrieves policy management-related capabilities from the MnS Producer as follows:

a. Receiving and storing policies from the MnS Consumer.

b. Evaluating the policies.

c. Detecting policy conflicts and reporting conflict information.

d. Making policy execution decisions. | O1-Interface [2] | +| Step 1 (O) | The MnS Consumer creates a policy with an associated unique identification to the MnS Producer via O1 interface, based on network and feature-related requirements. | | +| Step 2 (O) | After completion of the policy creation process, the MnS Producer notifies the MnS Consumer via O1 interface on the result of the policy creation process. | | + +| | | | +|-----------------|-------------------------------------------------------------------------------------------------------------|--| +| Step 3 (O) | MnS Consumer activates the specific policy in MnS Producer via O1 interface. | | +| Step 4 (O) | After the policy activation completed, the MnS Producer notifies the MnS Consumer via O1 interface. | | +| Step 5 (O) | MnS Consumer provides the revised policy to the MnS Producer via O1 interface. | | +| Step 6 (O) | After completion of the policy update process, the MnS Producer notifies the MnS Consumer via O1 interface. | | +| Step 7 (O) | The E2 node as NF detects the policy conflict and inform to MnS Producer. | | +| Step 8 (O) | MnS Producer notifies the policy conflict to MnS Consumer via O1 interface | | +| Step 9 (O) | MnS Consumer deactivates policy in the MnS Producer via O1 interface. | | +| Step 10 (O) | After the policy deactivation is completed, the MnS Producer notifies the MnS Consumer via O1 interface. | | +| Step 11 (O) | MnS Consumer deletes the policy in the MnS Producer. | | +| Step 12 (O) | Once the policy deletion is completed, the MnS Producer notifies the MnS Consumer. | | +| Step 13 (O) | MnS Consumer queries the status of policy in the MnS Producer. | | +| Step 14 (O) | The MnS Producer responds to the MnS Consumer with the policy status notification. | | +| Ends when | MnS Consumer removes all policies from the MnS Producer. | | +| Exceptions | None | | +| Post Conditions | MnS Consumer is informed about the result of policy management related actions. | | +| Traceability | REQ-M&O-FUN13.d, REQ-M&O-FUN13.e, REQ-M&O-FUN13.f | | + +![Sequence diagram showing the Policy Management Process between the Service Orchestration and Management Framework (MnS Consumer) and the O-RAN Managed Element (MnS Producer and NF).](fdc3d58a4882ee60f5cd7ee8af4b40b9_img.jpg) + +**Policy Management Process** + +``` + +sequenceDiagram + participant MnS_Consumer as MnS Consumer + participant MnS_Producer as MnS Producer (MnF for the NF) + participant NF as NF + + MnS_Consumer->>MnS_Producer: 0.a «O1» Retrieves policy management related capabilities of the O-CU-CP + activate MnS_Producer + MnS_Producer->>NF: 1 «O1» Create policy instance + activate NF + NF-->>MnS_Producer: 2 «O1» Policy creation notification + deactivate NF + MnS_Producer->>MnS_Consumer: [Policy creation] + deactivate MnS_Producer + + MnS_Consumer->>MnS_Producer: 3 «O1» Activate policy + activate MnS_Producer + MnS_Producer->>NF: 4 «O1» Policy activation notification + activate NF + NF-->>MnS_Producer: + deactivate NF + MnS_Producer->>MnS_Consumer: [Policy activation] + deactivate MnS_Producer + + MnS_Consumer->>MnS_Producer: 5 «O1» Update policy + activate MnS_Producer + MnS_Producer->>NF: 6 «O1» Policy update notification + activate NF + NF-->>MnS_Producer: + deactivate NF + MnS_Producer->>MnS_Consumer: [Policy update] + deactivate MnS_Producer + + MnS_Consumer->>MnS_Producer: 7 Detect policy conflict + activate MnS_Producer + MnS_Producer->>NF: 8 «O1» Policy conflict notification + activate NF + NF-->>MnS_Producer: + deactivate NF + MnS_Producer->>MnS_Consumer: [Policy conflict detection] + deactivate MnS_Producer + + MnS_Consumer->>MnS_Producer: 9 «O1» Deactivate policy + activate MnS_Producer + MnS_Producer->>NF: 10 «O1» Policy deactivation notification + activate NF + NF-->>MnS_Producer: + deactivate NF + MnS_Producer->>MnS_Consumer: [Policy deactivation] + deactivate MnS_Producer + + MnS_Consumer->>MnS_Producer: 11 «O1» Delete policy + activate MnS_Producer + MnS_Producer->>NF: 12 «O1» Policy removal notification + activate NF + NF-->>MnS_Producer: + deactivate NF + MnS_Producer->>MnS_Consumer: [Policy deletion] + deactivate MnS_Producer + + MnS_Consumer->>MnS_Producer: 13 «O1» Query the status of a policy + activate MnS_Producer + MnS_Producer->>NF: 14 «O1» Policy status response notification + activate NF + NF-->>MnS_Producer: + deactivate NF + MnS_Producer->>MnS_Consumer: [Policy query] + deactivate MnS_Producer + +``` + +The diagram illustrates the Policy Management Process. It is divided into two main sections: the Service Orchestration and Management Framework (left, yellow background) and the O-RAN Managed Element (right, pink background). The Service Orchestration and Management Framework contains an MnS Consumer. The O-RAN Managed Element contains an MnS Producer (MnF for the NF) and an NF. The process starts with the MnS Consumer sending a request (0.a «O1») to the MnS Producer to retrieve policy management related capabilities of the O-CU-CP. This is followed by a series of optional (opt) operations: Policy creation, Policy activation, Policy update, Policy conflict detection, Policy deactivation, Policy deletion, and Policy query. Each operation involves a request from the MnS Consumer to the MnS Producer, which then interacts with the NF to perform the action and return a notification to the MnS Producer, which finally returns the result to the MnS Consumer. + +Sequence diagram showing the Policy Management Process between the Service Orchestration and Management Framework (MnS Consumer) and the O-RAN Managed Element (MnS Producer and NF). + +Figure 4.2.6.4-1: Policy management procedure + +# 5 OAM Architecture + +## 5.1 Architectural Principles + +The following clause provides architecture principles guiding the support of OAM in the O-RAN architecture. Common OAM functions should be supported through a common set of OAM interface protocols across the different components of the O-RAN architecture. + +Management Services should, to the degree possible, align with existing standards specifications: + +- 3GPP 5G Specifications for management interfaces +- ETSI NFV Specifications for life cycle management +- OFH M-Plane [1] + +O-RAN OAM specifications should refer to the 3GPP and ETSI specs and not replicate them here. O-RAN OAM specifications shall identify needed extensions to support O-RAN and exceptions which cannot be supported. It is the goal of O-RAN to drive any needed extensions into standards to maintain alignment between O-RAN and existing standards. + +### 5.1.1 Alarm Dictionary Overview + +Entities that are part of an O-RAN deployment can emit alarm notifications to the SMO to indicate adverse conditions on the entity that the SMO needs to be aware of and potentially take corrective actions for. Entities typically emit alarm notifications on one OAM interface (O2-IMS or O2-DMS for Cloud, O1 for the MnF(s) of O-RAN NFs other than the O-RU, Open FH M-Plane for O-RU). + +The Alarm Dictionary allows the SMO to become aware of the alarming capabilities of the O-RAN entity. The alarm dictionary provided by the vendors will be provided in a common, machine-readable format. This will allow the service provider to have a common way of querying or displaying the information they need to help them determine what actions to take when an alarm occurs. The alarm dictionary contains an entry for each alarm that the product emits to the manager. Alarm notification formats are/will be standardized on these interfaces and will contain instance specific information about the condition triggering the alarm such as: an identifier for the alarm, what instance of the entity is alarming and to the degree possible pinpointing where the problem is originating from. Much of the information in the notification will be specific to this instance of the problem occurring. Some information associated with an alarm can be static (such as the alarm name or description) and not dependent upon the instance of the alarm sent in the alarm notification. Typically, this information is descriptive in nature such as providing a detailed description of why an alarm is raised, what the alarming condition means and its impact on the system and vendor suggested repair actions. To be efficient in transmission, O-RAN expects that vendors provide an alarm dictionary that contains this static information in a machine-readable format which the service provider can consult to determine what actions may be taken when a particular alarm notification is raised. + +The alarm dictionary is delivered to the manager as part of: + +- Onboarding package when a software delivery of an O-RAN NF or xApp/rApp is made. +- Registration when updates are made to O-Cloud entities. + +The alarm dictionary is stored in a repository where the SMO can access it upon reception of an alarm notification to display the information associated with an alarm to a human user to support determining what corrective action to take. The information in the alarm dictionary definitions is not delivered within the alarm notification. + +### 5.1.2 Alarm Dictionary Association with O-RAN Entities and Content + +Each entity emitting alarms has an alarm dictionary version associated with each of its software versions so the SMO can determine which alarm dictionary should be consulted when the entity emits an alarm. Typically, the alarm dictionary will be associated with one or more versions of a delivery of an entity. The alarm dictionary version changes only when an alarm is added to the dictionary, has an element in the dictionary change, or if an alarm is no longer supported. For this reason, a vendor may associate several deliveries of product with the same version of an alarm dictionary. + +A vendor shall update the alarm dictionary whenever an alarm is added, deleted, or modified in the product software and provide a “last change” indicator for each alarm entry to make it easy for an Operator to know what has changed from one version of the alarm dictionary to another. + +The alarm dictionary provides information about each alarm/alarm family that an O-RAN entity emits to the manager; information that is important for understanding and processing the alarm but is not provided as part of the alarm notification itself. The entries are formatted according to a common Alarm Dictionary schema that is applicable to all O-RAN alarms over any OAM interface (O1, O2, Open Fronthaul M-Plane, Transport). + +The alarm dictionary consists of: + +- Header – information common for all alarm entries in this version of the Alarm Dictionary +- Alarm Entries – one per alarm containing alarm-specific information + +Details shall be as defined in IM/DM [3]. + +### 5.1.3 Compatibility for O1 Interface + +#### 5.1.3.1 Introduction + +Compatibility of the Management Services offered by the MnS Producers (e.g., within NE) and MnS Consumers (e.g., within SMO) enables the correct interworking between them. Compatibility occurs when the MnS Consumer can use the MnS Producer profile, described in 3GPP TS 28.533 [i.4]. Management Services are described by the following three component types: + +- MnS component type A: Operations and notifications +- MnS component type B: Information model +- MnS component type C: Performance and Fault information + +#### 5.1.3.2 MnS Component type A Compatibility + +Editor's note: Content to be added later. + +#### 5.1.3.3 MnS Component type B Compatibility + +##### 5.1.3.3.1 Overview + +The information model (i.e., model schemas and associated model instances) is considered a system of models with dependency relations between their model elements as described in 3GPP TS 32.156 [i.17], clause 5. + +The evolution of the IM exposed by the MnS Producer (e.g., NE) can potentially cause incompatibility with the MnS Consumer (e.g., SMO) based on the use of the exposed IM. A MnS Consumer should be able to manage different NE instances with different MnS Producer profile variants. Likewise, a MnS Consumer that manages multiple NE instances can become incompatible with one or more NE instances that expose different variants of the MnS Producer profiles as described in 3GPP TS 28.533 [i.4], clause 4.2.4. + +The evolution of the information model either produced by the MnS Producer (e.g., NE) or consumed by the MnS Consumer (e.g., SMO) can be realised, for example: + +- Adding/removing new models exposed by a new MnS Producer +- Adding/modifying/removing model elements to/from an existing model exposed by a MnS Producer + +The compatibility between NE and SMO is defined by the ability of the SMO's MnS Consumer to manage the model elements in order to support the management of the RAN. + +This evolution of the information model exposed by the MnS Producer as well as the information model used by MnS Consumer requires mechanisms (e.g., identification of model changes) to maintain compatibility between information models of both the MnS Producer and MnS Consumer. + +Information Model compatibility scenarios are discussed in the following clauses, introducing the concepts of full and limited compatibility. + +##### 5.1.3.3.2 Information Model Compatibility Scenarios + +Editor's note: Content to be added later. + +#### 5.1.3.4 MnS Component type C Compatibility + +Editor's note: Content to be added later. + +## 5.2 Architecture Requirements + +Defines the Architecture requirements applicable to the O-RAN reference architecture. Architecture requirements are derived from Use Cases to be supported and define the functional needs the architecture aims to satisfy. + +### 5.2.1 Functional Requirements + +| REQ | Description | Note | +|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------| +| [REQ-M&O-FUN1] | O-RAN OAM Architecture shall support the interaction between the Service Management and Orchestration Framework and the O-Cloud through O2 interface to perform virtualized resource orchestration. | Use Case | +| [REQ-M&O-FUN2] | O-RAN OAM Architecture shall support the capability for the Service Management and Orchestration Framework to consume the provisioning management service exposed by the MnF of each O-RAN NF, regardless of whether the NF is implemented as PNF or VNF, through the O1 interface. | O1-Interface [2] | +| [REQ-M&O-FUN3] | O-RAN OAM Architecture shall support creation, modification, and termination of VNFs in an O-RAN network by the Service Management and Orchestration Framework | Use Case | +| [REQ-M&O-FUN4] | O-RAN OAM Architecture shall support registration and inventory of newly activated VNFs and PNFs by the Service Management and Orchestration Framework | Use Case | +| [REQ-M&O-FUN5] | O-RAN OAM Architecture shall support collection of status change and other indications from VNFs and PNFs by the Service Management and Orchestration Framework | Use Case | +| [REQ-M&O-FUN6] | O-RAN OAM Architecture shall support configuration of VNFs and PNFs by the Service Management and Orchestration Framework, including, for example, addressing information needed to allow them to connect to each other | Use Case | +| [REQ-M&O-FUN7] | O-RAN OAM Architecture shall support management of PM jobs, PM data collection/storage/query/statistical reports from MnFs of O-RAN NFs | Use Case | +| [REQ-M&O-FUN8] | O-RAN OAM Architecture shall support operation logging and operation authority of O-RAN NFs | Use Case | +| [REQ-M&O-FUN9] | O-RAN OAM Architecture shall support management of O-RAN NFs. | 3GPP TS 28.622 [i.2] | +| [REQ-M&O-FUN10] | O-RAN OAM Architecture shall support hierarchical and hybrid management of O-RAN O-DU and O-RU components as defined in OFH M-Plane [1] | Use Case & OFH M-Plane [1] | +| [REQ-M&O-FUN11] | O-RAN OAM Architecture and interfaces shall support network slicing, where an instance of O-RAN NF may be associated with one or more slices. | Use Case | +| [REQ-M&O-FUN12] | O-RAN OAM Architecture shall support O1 interface to the MnF of each O-RAN NF (with the exception of the RU) even if the MnF is deployed behind a NAT | O1-Interface [2] | +| [REQ-M&O-FUN13.a] | The O-RAN OAM Architecture shall support the capability of the Service Management and Orchestration (SMO) framework to discover the RAN FCAPS-related management capabilities of the O-RAN MnF that terminates the O1 interface. | O1-Interface [2] | +| [REQ-M&O-FUN13.b] | In case of the Hybrid Management Architecture Model, the O-RAN OAM Architecture shall support the capability of the Service Management and Orchestration (SMO) framework to discover the RAN FCAPS-related management capabilities of the O-RAN network function terminating the Open Fronthaul M-Plane interface. | OFH M-Plane [1] | + +| | | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------| +| [REQ-M&O-FUN13.c] | The Service Management and Orchestration (SMO) framework shall have the capability to discover the FCAPS-related management capabilities of the O-Cloud infrastructure. | O2-GA&P [i.9] | +| [REQ-M&O-FUN13.d] | O-RAN OAM Architecture shall support the capability for the Service Management and Orchestration (SMO) framework to provision NES policies over the O1 interface. | Clause 4.2.6; Use Case | +| [REQ-M&O-FUN13.e] | O-RAN OAM Architecture shall support the capability for the Service Management and Orchestration (SMO) framework to manage configuration of O-RAN NFs over the O1 interface. | Use Case | +| [REQ-M&O-FUN13.f] | O-RAN OAM Architecture shall support the capability for the Service Management and Orchestration (SMO) framework to be informed over the O1 interface about detected conflicts related to the policies provisioned over the O1 interface. | Use Case | +| [REQ-M&O-FUN14] | O-RAN OAM Architecture shall support Antenna Line Device (ALD) handling. | UC DetailedSpec [6], clause 4.20 | + +### 5.2.2 Non-Functional Requirements + +| | | | +|-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| [REQ-M&O-NFUN1] | O-RAN OAM Architecture shall support the introduction of new and more cost-effective technologies into the RAN through open, standard interfaces | O-RAN white paper [i.7] | +| [REQ-M&O-NFUN2] | O-RAN OAM Architecture shall support virtualization of RAN components, allowing operators use of common, off-the-shelf hardware implementations | O-RAN white paper [i.7] | +| [REQ-M&O-NFUN3] | O-RAN OAM Architecture shall support use of Analytics and Artificial Intelligence/Machine Learning to improve network efficiency and performance and reduce operations costs | O-RAN white paper [i.7] | +| [REQ-M&O-NFUN4] | O-RAN entities emitting alarms to the SMO shall provide an Alarm Dictionary with the product delivery that is delivered to the SMO at onboarding for O-RAN NFs, xApps and rApps or at registration for O-Cloud entities. | 5.1.1, 5.1.2 | +| [REQ-M&O-NFUN5] | The vendor shall update the alarm dictionary when the entity emitting the alarm supports a new alarm definition, the information associated with the alarm definition changes or the entity no longer supports an alarm definition. For each dictionary entry, the vendor shall indicate the last version in which the alarm entry changed. | 5.1.1, 5.1.2 | +| [REQ-M&O-NFUN6] | The SMO shall maintain the association between an entity version onboarded from a product delivery and its alarm dictionary. | 5.1.1, 5.1.2 | +| [REQ-M&O-NFUN8] | The Alarm Dictionary shall be delivered following the schema to be defined in the IM/DM specification. | 5.1.1, 5.1.2 | + +### 5.2.3 Security Requirements + +| | | | +|-----------------|----------------------------------------------------------------------------------------------------------|----------| +| [REQ-M&O-NFUN4] | O-RAN OAM Architecture shall support security of interactions between the components of an O-RAN network | See note | +|-----------------|----------------------------------------------------------------------------------------------------------|----------| + +Note: more detailed requirements for security are addressed in SecReqSpecs [4]. + +## 5.3 Reference Architecture + +The reference architecture defines a set of basic architectural building blocks – management services provided by the Management Function(s) of each O-RAN NF– for the O-RAN management domain. + +### 5.3.1 Architectural Building Blocks + +#### 5.3.1.1 O-RAN Management Services and Management Functions + +The definition of a Management Service (MnS) is given in 3GPP TS 28.533 [i.4], clause 3.1. O-RAN Management Services (MnS) offer capabilities to manage and orchestrate O-RAN Network Functions. Management Functions of O-RAN NFs expose their management services to consumers. The SMO consumes the management services. + +Examples of Management Services supported by O-RAN include: + +- Provisioning +- Fault Supervision +- Performance Assurance +- Trace Management +- File Management +- Software Management +- Communication Surveillance +- Startup and Registration of a Physical Network Function (PNF) +- Instantiation and Termination of a Virtualized Network Function (VNF) +- Scaling Management Services for VNF +- Policy Management + +The definitions of supported management services and their APIs are specified in O1-Interface [2]. + +The definition of a Management Function (MnF) is given in 3GPP TS 28.533 [i.4], clause 3.1. + +#### 5.3.1.2 O-RAN Network Elements + +The definition of a Network Element (NE) is given in 3GPP TS 21.905 [i.1], clause 3.N. In the O-RAN OAM Architecture, an O-RAN Network Element is a logical entity and aggregates O-RAN Network Functions. A set of Management Functions in the NE produce Management Services toward the SMO. + +#### 5.3.1.3 O-RAN Network Functions + +The O-RAN Network Functions (O-RAN NFs) are defined in OAD [i.10] and include: + +- Near-Real-Time Radio Intelligent Controller (Near-RT RIC) +- O-RAN Central Unit – Control Plane (O-CU-CP) +- O-RAN Central Unit – User Plane (O-CU-UP) +- O-RAN Distributed Unit (O-DU) +- O-RAN Radio Unit (O-RU) + +#### 5.3.1.4 Apps Hosted by O-RAN Near-RT RICs + +The Near-RT RIC has the capability to host Applications (called xApps). An xApp as described in OAD [i.10] is a software application that can be developed independently from its hosting Near-RT RIC instance. + +Management of xApps on a hosting Near-RT RIC shall comply with the following principles: + +- The hosting Near-RT RIC provides certain services to the xApps via well-defined APIs; +- The xApps are considered to be contained in the same logical Network Element (as defined in clause 5.3.1.2) as the hosting Near-RT RIC; +- The xApps may be managed through a set of O1 MnSs terminated on the containing NE. + +#### 5.3.1.5 Service Management and Orchestration Framework + +The Service Management and Orchestration Framework is responsible for the management and orchestration of the O-RAN NFs under its span of control. The framework can for example be implemented as a third-party Network Management System (NMS) or orchestration platform. + +The Service Management and Orchestration Framework shall provide an integration fabric and data services for the MnFs of the O-RAN NFs. The integration fabric enables interoperation and communication between the SMO and the various MnFs within the O-RAN domain. Data services provide efficient data collection, storage, and movement capabilities for the MnFs. In order to implement multiple OAM architecture options together with RAN service modeling, the modeling of different OAM deployment options and OAM services (integration fabric etc.) shall be supported by the SMO. + +#### 5.3.1.6 Non-Real Time Radio Intelligent Controller + +The Non-RT RIC is a part of the Service Management & Orchestration Framework and communicates to the Near-RT RIC using the A1 interface, as described in OAD [i.10]. + +Non-RT control functionality ( $> 1s$ ) and near-Real Time (near-RT) control functions ( $< 1s$ ) are decoupled in the RIC. Non-RT functions include service and policy management, RAN analytics and model-training for some of the near-RT RIC functionality, and non-RT RIC optimization. + +#### 5.3.1.7 Control Loop Support + +O-RAN defines 3 control loops with different latency bands, as described in OAD [i.10], clause 5.2. These loops are not hierarchical but instead run in parallel. This does not mean that an NF with an inner loop will not generate its own event as result of an inner loop failure, but it will not simply propagate the lower-level event received by the inner loop. The three loops are defined as: + +- Loop 1: In the O-DU for per TTI/msec resource scheduling ( $< 10$ millisecond) +- Loop 2: In the Near-RT RIC and O-CU for resource optimization (10 milliseconds to 1 second) +- Loop 3: In the Service Management and Orchestration Framework for ML Training, Trending, Orchestration ( $> 1$ second) + +### 5.3.2 Basic OAM Architecture + +The overall O-RAN Logical Architecture is shown in OAD [i.10], figure 5.1-2. The O1 interface identified in OAD [i.10], clause 5.1 is used for OAM functions between the O-RAN Service Management and Orchestration Framework and the MnFs of the O-RAN Network Functions (with the exception of the O-RU). + +![Figure 5.3.2-1 O-RAN Logical OAM Architecture, O1 and O2 Interfaces](974bf616440322c1bc8c2498f53bdc5c_img.jpg) + +The diagram illustrates the O-RAN Logical OAM Architecture. At the top is a purple box labeled 'Service Management and Orchestration Framework'. Below it, two interfaces are shown: 'O2' (green circle) connects to a green box labeled 'O-Cloud'; 'O1 MnSs' (green circle) connects to an orange box labeled 'O-RAN NE'. Inside the 'O-RAN NE' box, there are three red boxes labeled 'O-RAN NF'. + +Figure 5.3.2-1 O-RAN Logical OAM Architecture, O1 and O2 Interfaces + +**Figure 5.3.2-1 O-RAN Logical OAM Architecture, O1 and O2 Interfaces** + +Figure 5.3.2-1 depicts the O-RAN Logical OAM Architecture for the O1 and O2 interfaces. An O1 interface as described in O1-Interface [2] consists of a set of O-RAN Management Services that together allow management of a set of O-RAN Network Functions of an O-RAN Network Element. An O2 interface as described in O2-GA&P [i.9] consists of services, provided by the O-Cloud, to enable the SMO as a consumer to manage both cloud infrastructure and cloud deployments. The O2 interface has different requirements from the O1 interface. + +![Figure 5.3.2-2 O-RAN Logical OAM Architecture, Hierarchical M-Plane](0b7d9b9ee86afab230f3c4619c4a25ff_img.jpg) + +The diagram illustrates the O-RAN Logical OAM Architecture in a hierarchical M-Plane model. At the top is a purple box labeled 'Service Management and Orchestration Framework'. Below it, the 'O1 MnSs' (green circle) interface connects to an orange box labeled 'O-DU O-RAN NE'. This box contains a red box labeled 'O-DU'. Below the 'O-DU' box, the 'Open FH M-Plane' (green circle) interface connects to another orange box labeled 'O-RU O-RAN NE', which contains a red box labeled 'O-RU'. + +Figure 5.3.2-2 O-RAN Logical OAM Architecture, Hierarchical M-Plane + +**Figure 5.3.2-2 O-RAN Logical OAM Architecture, Hierarchical M-Plane** + +Figure 5.3.2-2 depicts the management of an O-RU in the hierarchical model of operation. OFH M-Plane [1], clause 5.1.2 defines the M-Plane architecture model. In the O-RAN Open FH M-Plane hierarchical model, the O-RU is managed by one or more O-DUs using the Open FH M-Plane, and the O-DU presents the O-RU to the SMO via the O1 interface. + +![Figure 5.3.2-3 O-RAN Logical OAM Architecture, Hybrid M-Plane. This diagram shows a hierarchical architecture. At the top is a purple box labeled 'Service Management and Orchestration Framework'. Below it is an orange box labeled 'O-DU' with 'O-RAN NE' underneath. At the bottom is another orange box labeled 'O-RU' with 'O-RAN NE' underneath. A green line labeled 'O1 MnSs' connects the top framework to the O-DU box. A green line labeled 'Open FH M-Plane (Hybrid)' connects the top framework to the O-RU box. A green line labeled 'Open FH M-Plane' connects the O-DU box to the O-RU box.](a179f4bd7ca6021e452bf2ccca66762e_img.jpg) + +Figure 5.3.2-3 O-RAN Logical OAM Architecture, Hybrid M-Plane. This diagram shows a hierarchical architecture. At the top is a purple box labeled 'Service Management and Orchestration Framework'. Below it is an orange box labeled 'O-DU' with 'O-RAN NE' underneath. At the bottom is another orange box labeled 'O-RU' with 'O-RAN NE' underneath. A green line labeled 'O1 MnSs' connects the top framework to the O-DU box. A green line labeled 'Open FH M-Plane (Hybrid)' connects the top framework to the O-RU box. A green line labeled 'Open FH M-Plane' connects the O-DU box to the O-RU box. + +**Figure 5.3.2-3 O-RAN Logical OAM Architecture, Hybrid M-Plane** + +Figure 5.3.2-3 depicts the management of an O-RU in the hybrid model of operation. In the O-RAN Open FH M-Plane hybrid model, some OAM functions of the O-RU can also be managed directly by the SMO using the Open FH M-Plane. NOTE: the figure uses 5G terminology; however, the same principles will apply for LTE/4G. + +3GPP TS 28.533 [i.4], figure 4.5.2 shows examples of MnS deployment scenarios. In the case where Management Functions are deployed as a separate entity from the O-RAN NF (rather than embedded), an O-RAN Network Element contains one or more MnFs producing one or more O1 management services for any number of non-O-RU O-RAN NFs, as shown in Figure 5.3.2-4. The interfaces between the O-RAN NFs and the MnFs within an NE are outside the scope of the O-RAN standardization domain. One or more of the O-RAN NFs in an NE may be Near-RT RICs. The hosted xApps may also be managed through one or more of the MnFs in the NE containing a Near-RT RIC. + +![Figure 5.3.2-4 O-RAN Logical Network Element. This diagram shows an orange box representing an 'O-RAN NE'. Inside the box, on the left, is a blue box labeled 'MnF' with '1..m MnFs' below it. On the right, there is a stack of components: a red box labeled 'Near-RT RIC' with '0..j xApps' above it, and a red box labeled 'O-RAN NF' below it, with '1..n O-RAN NFs' below that. A green line labeled '1..k O1 MnSs' enters the box from the top and connects to the MnF box.](8de501114191483006c6ce93c404ecb7_img.jpg) + +Figure 5.3.2-4 O-RAN Logical Network Element. This diagram shows an orange box representing an 'O-RAN NE'. Inside the box, on the left, is a blue box labeled 'MnF' with '1..m MnFs' below it. On the right, there is a stack of components: a red box labeled 'Near-RT RIC' with '0..j xApps' above it, and a red box labeled 'O-RAN NF' below it, with '1..n O-RAN NFs' below that. A green line labeled '1..k O1 MnSs' enters the box from the top and connects to the MnF box. + +**Figure 5.3.2-4 O-RAN Logical Network Element** + +An O-RU does not conform to the concept of an O-RAN Logical Network Element, since the O-RU exposes the Open FH M-Plane interface rather than O1, and thus it does not expose any 3GPP-aligned MnS. As well, the O-RU can only be deployed as a PNF, and not as a deployment-independent logical function. + +The O1 Interface includes implementation of Fault, Configuration, Accounting, Performance, Security (FCAPS) functions, File management and Software management functions for O-RAN Network Functions. For details of the management services supported by O1, see O1-Interface [2]. + +The O2 Interface enables the management of O-Cloud infrastructures and the deployment life cycle management of O-RAN cloudified NFs that run on an O-Cloud. For details of the functions supported by O2, see O2-GA&P [i.9]. + +The Open FH M-Plane Interface includes implementation of Fault, Configuration, Accounting, Performance, Security (FCAPS) functions, File management and Software management functions for O-RU. It also specifies the carrier management aspects and is used between O-DU and O-RU. + +### 5.3.3 O-RU Management Models and Managed Deployment Options + +This clause describes some of the possible O-RU management models, providing a high-level description of the models. O-RAN supports multiple deployment options. Adoption of a single O-RU management model or managed deployment option is not required in the O-RAN OAM Architecture. Multiple combinations of deployments may be supported in a network. + +#### 5.3.3.1 Flat Management Architecture Model + +In the flat model, all entities/nodes are managed directly by the SMO. + +#### 5.3.3.2 Hierarchical Management Architecture Model + +In the hierarchical model, all entities/nodes except for O-RUs are managed directly by the SMO, but the O-RU is managed directly by the O-DU (and indirectly by the SMO). Clause 4.2.4 of this document specifies the hierarchical management of the O-RU through the O-DU. OFH M-Plane [1] specifies the details of the use of the hierarchical model for the O-RAN O-RU. + +#### 5.3.3.3 Hybrid Management Architecture Model + +In the hybrid model, all entities/nodes except for O-RUs are managed directly by the SMO. The O-RU is partially managed by the SMO (for FCAPS support) and partially managed by the O-DU. Details of the hybrid model for the O-RU including privilege division between SMO and O-DU can be found in OFH M-Plane [1]. + +#### 5.3.3.4 Example Managed Deployment Options + +O-RAN also supports multiple deployment options. OAD [i.10], Annex A provides several examples of O-RAN deployments. The choice of deployment option is at the discretion of the service provider. + +### 5.3.4 Network Functions Deployed behind a NAT + +Service Providers prefer to not deploy Network Functions behind a NAT, but there are cases where this cannot be avoided, for example: + +- exhaustion of public IPv4 addresses +- deployment in large complexes not owned by the Service Provider (Apartments, Sports Venues etc.) +- connections via third-party networks using a NAT + +When a Service Provider deploys NFs behind a NAT it is critical that they are able to retain full management control of these entities. + +![Diagram illustrating O-RAN Network Functions (NFs) deployed behind a NAT. The diagram shows three separate clouds, each labeled 'Network with NAT (private IP addresses)'. Each cloud contains a 'FIREWALL' icon and several 'NF' (Network Function) icons. These three NATed networks are connected to a central cloud labeled 'Internet (public IP addresses)'. The central Internet cloud is also connected to a fourth cloud labeled 'Network owned/managed by Service provider', which contains an 'NF' icon and is connected to the Internet cloud via a 'FIREWALL' icon.](a51b29f0dca432d963d302da85759e05_img.jpg) + +Diagram illustrating O-RAN Network Functions (NFs) deployed behind a NAT. The diagram shows three separate clouds, each labeled 'Network with NAT (private IP addresses)'. Each cloud contains a 'FIREWALL' icon and several 'NF' (Network Function) icons. These three NATed networks are connected to a central cloud labeled 'Internet (public IP addresses)'. The central Internet cloud is also connected to a fourth cloud labeled 'Network owned/managed by Service provider', which contains an 'NF' icon and is connected to the Internet cloud via a 'FIREWALL' icon. + +Figure 5.3.4-1 O-RAN NFs behind a NAT + +Four methods of providing the O-RAN SMO with the ability to address a NF behind a NAT and identify data received for a NF behind a NAT are recommended in priority order: + +1. Use of IPv6 as Backhaul transport where possible, eliminating the need for a NAT due to exhaustion of public IPv4 addresses +2. Use of persistent VPN tunnels (e.g., IPSec) toward a VPN concentrator (gateway) located outside of network with the NAT. The NF is then accessible through the established tunnel. +3. Use of standard protocol (UPNP or PCP) to establish a port-forwarding rule at the firewall and automatically assign itself a port. +4. Service Provider manually configures the firewall to assign a port to an entity that resides within the protected network. + +### 5.3.5 Relationships between the O1 NRM entities and Architectural entities + +#### 5.3.5.1 Introduction + +The architectural entities described in clause 5.3.2 have associated management entities described in O1-NRM [i.16] that encapsulate the manageable characteristics and behaviors of these architectural entities. + +#### 5.3.5.2 Managed object relationships to NE and NF architectural entities + +The O-RAN NE and NF entities defined in OAD [i.10] are subtypes of, respectively, the 3GPP NE defined in 3GPP TR 21.905 [i.1] and the 3GPP NF defined in 3GPP TS 23.501 [i.15]. As such, the corresponding 3GPP management entities are used to encapsulate the manageable characteristics and behaviors of the O-RAN NE and NF entities. The ManagedElement IOC provides the manageable characteristics and behaviours for the O-RAN NE, and the ManagedFunction IOC provides the manageable characteristics and behaviours for the O-RAN NF. These relationships are depicted in Figure 5.3.5.2-1. + +NOTE: By the time the O-RAN NE has been discovered, the O-RAN NE is expected to be comprised of at least 1 O-RAN NF. + +![UML class diagram showing ManagedElement and ManagedFunction relationships to 3GPP and O-RAN entities.](b27cab4efd103bbfc3468cb24d8cad92_img.jpg) + +``` + +classDiagram + class ManagedElement["«InformationObjectClass» ManagedElement"] + class ManagedFunction["«InformationObjectClass» ManagedFunction"] + class NE["«3GPP Entity» NE"] + class NF["«3GPP Entity» NF"] + class O_RAN_NE["«O-RAN Entity» O-RAN NE"] + class O_RAN_NF["«O-RAN Entity» O-RAN NF"] + + ManagedElement --> NE : encapsulates manageable characteristics and behaviors 1 + ManagedFunction --> NF : encapsulates manageable characteristics and behaviors 0..1 + NE <|-- O_RAN_NE + NF <|-- O_RAN_NF + O_RAN_NF --> O_RAN_NE : offers 1 + +``` + +The diagram illustrates the managed object relationships between O-RAN NE and NF architectural entities and their corresponding management entities. It shows two rows of relationships. The top row shows that the «InformationObjectClass» ManagedElement encapsulates the manageable characteristics and behaviors of the «3GPP Entity» NE (multiplicity 1). The «3GPP Entity» NE is a generalization of the «O-RAN Entity» O-RAN NE. The bottom row shows that the «InformationObjectClass» ManagedFunction encapsulates the manageable characteristics and behaviors of the «3GPP Entity» NF (multiplicity 0..1). The «3GPP Entity» NF is a generalization of the «O-RAN Entity» O-RAN NF. Additionally, there is a relationship where the «O-RAN Entity» O-RAN NF offers the «O-RAN Entity» O-RAN NE (multiplicity 1). A note indicates that post discovery and initial configuration of the O-RAN NE, there will be at least 1 O-RAN NF during normal operations. + +UML class diagram showing ManagedElement and ManagedFunction relationships to 3GPP and O-RAN entities. + +Figure 5.3.5.2-1 Managed Object Relationship with O-RAN NE and NF + +#### 5.3.5.3 MnF relationships to NF, NE and MnS architectural entities + +As described in clause 5.3.1.1, the MnF exposes management services defined by the O-RAN MnS by acting as an MnS Producer for the O-RAN MnS. The O-RAN MnS is considered a subtype of the MnS defined in 3GPP TS 28.533 [i.4], clause 3.1. Likewise, the O-RAN MnF is considered a subtype of the MnF defined in 3GPP TS 28.533 [i.4], clause 3.1. By acting as a MnS Producer, the O-RAN MnF provides the manageable characteristics and behaviours for a set of O-RAN NFs. These relationships are depicted in Figure 5.3.5.3-1. + +NOTE: An O-RAN MnF that provides the manageable characteristics and behaviour for an O-RAN NF does not have to be comprised within the same instance of an O-RAN NE. + +![UML class diagram showing MnF relationships to NF, NE and MnS architectural entities. The diagram includes entities: «O-RAN Entity» O-RAN NF, «O-RAN Entity» O-RAN MnF, «3GPP Entity» MnF, «3GPP Entity» NF, «O-RAN Entity» O-RAN NE, «3GPP Entity» MnS Producer, «O-RAN Entity» O-RAN MnS, and «3GPP Entity» MnS. Relationships: O-RAN NF *--> O-RAN MnF (manages), O-RAN MnF *--> 3GPP MnF (manages), 3GPP MnF *--> 3GPP NF (manages), O-RAN MnF *--> O-RAN NE (offers), O-RAN NE 1--> O-RAN MnF, 3GPP MnF 1--> 3GPP MnS Producer (plays the role of), 3GPP MnS Producer *--> 3GPP MnS (produces), O-RAN MnS *--> 3GPP MnS Producer.](31dc9614a9aa28907d66f24a332b6d55_img.jpg) + +The O-RAN MnF that manages the O-RAN NF can be offered by different O-RAN NEs. +Example: NE that comprises an O-DU manages an O-RU. + +``` + +classDiagram + class O_RAN_NF["«O-RAN Entity» O-RAN NF"] + class O_RAN_MnF["«O-RAN Entity» O-RAN MnF"] + class MnF["«3GPP Entity» MnF"] + class NF["«3GPP Entity» NF"] + class O_RAN_NE["«O-RAN Entity» O-RAN NE"] + class MnS_Producer["«3GPP Entity» MnS Producer"] + class O_RAN_MnS["«O-RAN Entity» O-RAN MnS"] + class MnS["«3GPP Entity» MnS"] + + O_RAN_NF "*" --> "*" O_RAN_MnF : manages + O_RAN_MnF "*" --> "*" MnF : manages + MnF "*" --> "*" NF : manages + O_RAN_MnF "*" --> "1" O_RAN_NE : offers + O_RAN_NE "1" --> "*" O_RAN_MnF + MnF "1" --> "*" MnS_Producer : plays the role of + MnS_Producer "*" --> "1" MnS : produces + O_RAN_MnS "*" --> "*" MnS_Producer + +``` + +UML class diagram showing MnF relationships to NF, NE and MnS architectural entities. The diagram includes entities: «O-RAN Entity» O-RAN NF, «O-RAN Entity» O-RAN MnF, «3GPP Entity» MnF, «3GPP Entity» NF, «O-RAN Entity» O-RAN NE, «3GPP Entity» MnS Producer, «O-RAN Entity» O-RAN MnS, and «3GPP Entity» MnS. Relationships: O-RAN NF \*--> O-RAN MnF (manages), O-RAN MnF \*--> 3GPP MnF (manages), 3GPP MnF \*--> 3GPP NF (manages), O-RAN MnF \*--> O-RAN NE (offers), O-RAN NE 1--> O-RAN MnF, 3GPP MnF 1--> 3GPP MnS Producer (plays the role of), 3GPP MnS Producer \*--> 3GPP MnS (produces), O-RAN MnS \*--> 3GPP MnS Producer. + +Figure 5.3.5.3-1 MnF relationships to NF, NE and MnS architectural entities + +# 6 Application Lifecycle Management (LCM) + +This chapter describes Lifecycle Management of applications that are developed by a Solution Provider and delivered to a Service Provider or Network Operator for deployment in O-RAN. The chapter's current focus is on LCM of rApps and xApps, both as defined in OAD [i.10]. + +Lifecycle Management follows the basic models of a Software Development Lifecycle by defining the transitional information from one state to another. There are several Software Development Life Cycle (SDLC) definitions. For the purposes of discussion this document generally follows a 7-state model as shown in Figure 6-1. Some states may also include activities that align with other states. However, this level of detail is not depicted here in order to introduce those details later in the document. + +A Service Provider or Network Operator has needs which are fulfilled by a Solution Provider. Once the Solution Provider delivers the application it is validated in a test environment prior to giving to operations to deploy. Usage of the deployed application may result in changes to configuration by the Service Provider or may be feedback to Solution Providers to evolve the capabilities of the network and/or its management. + +Although applications may come in many forms the delivery from the Solution Provider to the Service Provider needs to be done in a standardized manner. The seven steps defined in the SDLC are high level. Each may break down into a set of finer grain steps. + +![Figure 6-1: Generalized Lifecycle. A circular diagram showing the 7-state model of the Software Development Lifecycle. The states are: Needs (orange), Ideation (grey), Analysis (yellow), Develop (blue), Deliver (green), Validate (orange), and Operate (grey). The diagram is divided into two sections: Service Provider (top half) and Solution Provider (bottom half). Arrows indicate the flow between states: Needs to Ideation, Ideation to Analysis, Analysis to Develop, Develop to Deliver, Deliver to Validate, Validate to Operate, and Operate back to Needs.](5033dca804ae78eacb57453ab177ae51_img.jpg) + +Figure 6-1: Generalized Lifecycle. A circular diagram showing the 7-state model of the Software Development Lifecycle. The states are: Needs (orange), Ideation (grey), Analysis (yellow), Develop (blue), Deliver (green), Validate (orange), and Operate (grey). The diagram is divided into two sections: Service Provider (top half) and Solution Provider (bottom half). Arrows indicate the flow between states: Needs to Ideation, Ideation to Analysis, Analysis to Develop, Develop to Deliver, Deliver to Validate, Validate to Operate, and Operate back to Needs. + +Figure 6-1: Generalized Lifecycle + +## 6.1 Scope + +The end-to-end lifecycle involves two entities, the Solution Provider and the Service Provider. The Solution Provider provides applications for the Service Provider to use in their network. The working flow may be summarized as three phases: Development, Onboarding and Operations, as shown in Figure 6.1-1. + +![Figure 6.1-1 Application Lifecycle Phases diagram](fc4134aefccbb95052b23a446e9b6e7f_img.jpg) + +``` + +graph LR + subgraph "App Development" + A1[Ideation] + A2[Analysis] + A3[Development] + A4[Delivery] + end + subgraph "App Onboarding" + B1[Onboarding] + B2[Validation] + end + subgraph "App Operation" + C1[Management] + C2[Monitoring] + end + "App Development" -- "App/Model Package" --> "App Onboarding" + "App Onboarding" -- "App/Model Catalogue" --> "App Operation" + "App Operation" -- "Needs/Sample Data/Feedback/Optimization request" --> "App Development" + +``` + +The diagram illustrates the Application Lifecycle Phases, which are divided into three main stages: "App Development", "App Onboarding", and "App Operation". + +- "App Development"** (represented by a grey rounded rectangle) contains four sub-phases: Ideation, Analysis, Development, and Delivery (all in blue boxes). +- "App Onboarding"** (represented by a grey rounded rectangle) contains two sub-phases: Onboarding and Validation (both in green boxes). +- "App Operation"** (represented by a grey rounded rectangle) contains two sub-phases: Management and Monitoring (both in yellow boxes). + +The flow of the lifecycle is as follows: + +- An arrow labeled "App/Model Package" points from "App Development" to "App Onboarding". +- An arrow labeled "App/Model Catalogue" points from "App Onboarding" to "App Operation". +- A feedback loop arrow labeled "Needs/Sample Data/Feedback/Optimization request" points from "App Operation" back to "App Development". + +Figure 6.1-1 Application Lifecycle Phases diagram + +**Figure 6.1-1 Application Lifecycle Phases** + +These applications should be onboarded in a common manner, regardless of how they are deployed. This clause of the specification focuses on the data that is included in the App Package as it is exchanged between the Solution Provider and the Service Provider. This exchange is referred to as the “SP” exchange. This is not a formal interface between systems and therefore is not denoted as other O-RAN interfaces are. Care is given as not to put implementation or tooling mandates on either the Solution Provider in their development of the application, or the Service Provider in the aspect of training or deploying the application. Aspects of the lifecycle across both parties are introduced. However, not all aspects are discussed. Instead, the focus is on those activities that affect the data contained in the SP Exchange. Later in this document the term “Service Planning” is used to represent activities internal to the Service Provider. This is not the same as the “SP Exchange” used to describe the data passed from the Solution Provider to the Service Provider. The method of the SP Exchange is not defined in this document. It is sometimes referred to as the “Marketplace”. The marketplace may be implemented by either the solution provider, the service provider, or an external entity to both. The Marketplace simply represents an exchange between entities which may be done by electronic means or physical media. + +The App Development may provide application solutions with or without AI/ML models, while “App Onboard” and “App Operate” are responsible for application onboarding and operations. The application development may be completed in the environment provided by the Service Provider to provide additional privacy and security for the Service Provider. + +Applications may or may not utilize AI/ML models. Therefore, although the Model Information may be optional in the App Package, data exchange in the Application Package for applications utilizing AI/ML models is also included. + +### 6.1.1 Application Package Model + +The following UML® diagram illustrates the high-level composition of the **Application Package (AppPackage)**. An **Application Package** is the basic unit exchanged between the Solution Provider and Service Provider. The attributes of the entities in the diagram are representative. + +NOTE: UML is a registered trademarks/service mark of the Object Management Group, in the United States and other countries. O-RAN is not affiliated with, endorsed, or sponsored by the Object Management Group. + +![Figure 6.1.1-1: Application Package High Level Model. This UML class diagram shows the relationships between various model elements. AppPackage (blue) has a 'Has' relationship with DeploymentDescriptor (blue), a 'May Have' relationship with MLModelDescriptor (pink), and a 'Has' relationship with ManagementDescriptor (yellow). DeploymentDescriptor (blue) has a 'Has' relationship with DeploymentItem (blue). DeploymentItem (blue) has a 'May Have' relationship with ComponentDescriptor (yellow). ComponentDescriptor (yellow) has a 'May Have' relationship with ManagementDescriptor (yellow). ManagementDescriptor (yellow) has a 'Has' relationship with SecurityDescriptor (yellow), AlarmDictionary (yellow), ConfigurationModel (yellow), AccountingDictionary (yellow), and PerformanceDictionary (yellow). DeploymentItem (blue) also has a 'Has' relationship with CloudNativeDescriptorFile (green) and a 'May Have' relationship with ExecutableImage (green). ComponentDescriptor (yellow) has a 'May Have' relationship with RTEDescriptor (pink). CloudNativeDescriptorFile (green) has a 'May Have' relationship with ExecutableImage (green).](a558e09c0e45f80d4f265a961213e71c_img.jpg) + +``` + +classDiagram + class AppPackage + class DeploymentDescriptor + class MLModelDescriptor + class DeploymentItem + class ComponentDescriptor + class ManagementDescriptor + class CloudNativeDescriptorFile + class ExecutableImage + class RTEDescriptor + class SecurityDescriptor + class AlarmDictionary + class ConfigurationModel + class AccountingDictionary + class PerformanceDictionary + + AppPackage --> DeploymentDescriptor : Has + AppPackage --> MLModelDescriptor : May Have + AppPackage --> ManagementDescriptor : Has + DeploymentDescriptor --> DeploymentItem : Has + DeploymentItem --> ComponentDescriptor : May Have + ComponentDescriptor --> ManagementDescriptor : May Have + ManagementDescriptor --> SecurityDescriptor : Has + ManagementDescriptor --> AlarmDictionary : Has + ManagementDescriptor --> ConfigurationModel : Has + ManagementDescriptor --> AccountingDictionary : Has + ManagementDescriptor --> PerformanceDictionary : Has + DeploymentItem --> CloudNativeDescriptorFile : Has + DeploymentItem --> ExecutableImage : May Have + ComponentDescriptor --> RTEDescriptor : May Have + CloudNativeDescriptorFile --> ExecutableImage : May Have + +``` + +Figure 6.1.1-1: Application Package High Level Model. This UML class diagram shows the relationships between various model elements. AppPackage (blue) has a 'Has' relationship with DeploymentDescriptor (blue), a 'May Have' relationship with MLModelDescriptor (pink), and a 'Has' relationship with ManagementDescriptor (yellow). DeploymentDescriptor (blue) has a 'Has' relationship with DeploymentItem (blue). DeploymentItem (blue) has a 'May Have' relationship with ComponentDescriptor (yellow). ComponentDescriptor (yellow) has a 'May Have' relationship with ManagementDescriptor (yellow). ManagementDescriptor (yellow) has a 'Has' relationship with SecurityDescriptor (yellow), AlarmDictionary (yellow), ConfigurationModel (yellow), AccountingDictionary (yellow), and PerformanceDictionary (yellow). DeploymentItem (blue) also has a 'Has' relationship with CloudNativeDescriptorFile (green) and a 'May Have' relationship with ExecutableImage (green). ComponentDescriptor (yellow) has a 'May Have' relationship with RTEDescriptor (pink). CloudNativeDescriptorFile (green) has a 'May Have' relationship with ExecutableImage (green). + +**Figure 6.1.1-1: Application Package High Level Model** + +The following modifiers can be pre-pended to Model Elements to indicate context: + +- “Solution” The version of the element as defined by the Solution Provider +- “Onboarded” The initial version of the catalogued elements created during onboarding. +- “Catalogue” Subsequent versions of the catalogued package or its elements which may have been adjusted by the Service Provider. + +The **AppPackage** contains the **DeploymentDescriptor** and the **ManagementDescriptor**. An optional **MLModelDescriptor** is supplied for an application employing ML technology. + +The **DeploymentDescriptor** describes the deployment options for the application that have been validated by the Solution Provider. It includes one or more **DeploymentItems** describing the requirements for O-Cloud deployment of the application. The **DeploymentDescriptor** and **DeploymentItem** are consumed by the SMO/NFO. + +The **ManagementDescriptor** describes the application contained in the **AppPackage**. It contains one or more **ComponentDescriptors** describing the components to be deployed as part of the application as well as elements used for FCAPS functions for the **AppPackage** such as an **AlarmDictionary**, **ConfigurationModel**, **SecurityDescriptor**, etc. The **ManagementDescriptor** and its components are consumed by the SMO/FOCOM. + +ML Models may be pre-trained by the Solution Provider and therefore provide initial Training History. The Service Provider may also train the model or retrain the model with a more specialized data set, this is called *specialization*. The Training History provides the mechanism to record all training and subsequent specializations applied to that training through the Training History. + +An example of specialization is a ML Model created to predict the flow of traffic volumes. This algorithm can be generally trained to follow road patterns for devices with a velocity greater than 20 miles per hour. This training may be done by the Solution Provider on a generalized or open data set and recorded in the **MLModelDescriptor**. After onboarding the Service Provider may provide specialized training for dense urban traffic patterns which don’t always follow the roads due to periodic traffic congestion This would be an additional Training History record added by the **Service Provider** and referenced as specialization in the Catalogue Training History. Further refinement may also be applied for specific cities such as New York, Los Angeles, or San Francisco which would now add 3 specializations Catalogue Training History records relating to the dense urban Catalogue Training History which is a specialization if the Onboarded Training History. + +Once a Catalogue **DeploymentDescriptor** is validated as safe for use in operations it is published to a runtime environment as a Published **DeploymentDescriptor**. Runtime instance data may be applied to the Published **DeploymentDescriptor**. Applications deployed as part of this activity are called App Instances. An App Instance running in the Non-RT RIC Runtime can be referred to as an rApp instance. An App Instance running in the near-RT RIC Runtime can be referred to as an xApp instance. An App Instance running in a training environment is referred to as a Training App instance. + +#### **Diagramming Legend** + +The legend depicted in Figure 6.1.1-2 is used across all lifecycle diagrams in this clause and is shown once so it is not required on every diagram. Bolded text on a diagram is an item identified as requiring further discussion later in the document. Text in *Italics* are items identified for completeness but not requiring further discussion. Meet-Me-Points (MMPs) are places where a major aspect of the lifecycle interchanges. Data may be exchanged through these MMPs but the exact mechanism of the exchange is outside the scope of this document. Destination or Decision points are color + +coded according to their user community. Destination or Decision points are not a contributing factor to the data demands of the “SP” Exchange and are therefore not named. Instead the actions or conditions that are used as a transition between points are named as the items of interest. + +![Figure 6.1.1-2: Life Cycle Diagram Legend. The legend is divided into two main sections: 'Legend' and 'Destination or Decision Points'. The 'Legend' section defines 'Action' as a topic requiring further analysis and 'Condition' as something out of scope. It also shows 'Meet-Me-Points (MMP)' with 'External MMP' and 'Internal MMP' boxes. The 'Destination or Decision Points' section lists five phases with corresponding colored circles: Blue Line (App Development Phase), Green Line (App Onboarding Phase), Yellow Line (App Operations [Network] Phase), Purple Line (App Operations [SMO] Phase), and Light Blue Line (App Onboarding Phase (Provider Hosted Training)).](d1a57bd811eacc012a5cc5f4a6b702d9_img.jpg) + +Figure 6.1.1-2: Life Cycle Diagram Legend. The legend is divided into two main sections: 'Legend' and 'Destination or Decision Points'. The 'Legend' section defines 'Action' as a topic requiring further analysis and 'Condition' as something out of scope. It also shows 'Meet-Me-Points (MMP)' with 'External MMP' and 'Internal MMP' boxes. The 'Destination or Decision Points' section lists five phases with corresponding colored circles: Blue Line (App Development Phase), Green Line (App Onboarding Phase), Yellow Line (App Operations [Network] Phase), Purple Line (App Operations [SMO] Phase), and Light Blue Line (App Onboarding Phase (Provider Hosted Training)). + +Figure 6.1.1-2: Life Cycle Diagram Legend + +### 6.1.2 App Development Lifecycles + +In the App Development Lifecycle only two aspects are defined, the **Solution AppPackage** Lifecycle and the **Solution App** Lifecycle. + +#### 6.1.2.1 Solution App Lifecycle + +The Development Lifecycle steps related to the Solution App are shown below in Figure 6.1.2.1-1. + +![Figure 6.1.2.1-1: Solution App Development Lifecycle. The diagram shows a vertical 'Marketplace' bar on the left. A horizontal flow starts from the Marketplace, passing through 'Ideation', 'Analysis', 'Development', and 'Train' (each represented by a blue circle). From the 'Train' circle, a curved arrow labeled 'Build' points down to a 'Repository' cylinder. Another curved arrow points from the 'Repository' back up to the 'Train' circle, completing a loop.](6d3eecbb74f03209d941072fca0bdcb8_img.jpg) + +Figure 6.1.2.1-1: Solution App Development Lifecycle. The diagram shows a vertical 'Marketplace' bar on the left. A horizontal flow starts from the Marketplace, passing through 'Ideation', 'Analysis', 'Development', and 'Train' (each represented by a blue circle). From the 'Train' circle, a curved arrow labeled 'Build' points down to a 'Repository' cylinder. Another curved arrow points from the 'Repository' back up to the 'Train' circle, completing a loop. + +Figure 6.1.2.1-1: Solution App Development Lifecycle + +Customer feedback can consist of use case requirements, feature requests, defect notifications, or a variety of other comments. These feed the development cycle to develop new application or enhance existing ones. Requirements are usually identified and sent to developers to implement. The outcome of the build process is the container images built using SDKs for their intended deployments. If the application is AI/ML enabled, then the training action is done. The training may happen with synthetic data or with data provided by Service Providers. Information on the training performed is included in the Solution Training History. The completed Solution App is stored in a development repository. + +#### 6.1.2.2 Solution AppPackage Lifecycle + +The Development Lifecycle steps related the Solution AppPackage are shown below in Figure 6.1.2.2-1. + +![Figure 6.1.2.2-1: Solution AppPackage App Development Lifecycle. A flow diagram showing the process: Pack (from Repository) -> Secure -> Deliver -> Marketplace.](3310e16b57069122a94db2a3f1864c94_img.jpg) + +``` + +graph LR + Repository[(Repository)] -- Pack --> Secure((Secure)) + Secure -- Deliver --> Marketplace[Marketplace] + +``` + +Figure 6.1.2.2-1: Solution AppPackage App Development Lifecycle. A flow diagram showing the process: Pack (from Repository) -> Secure -> Deliver -> Marketplace. + +**Figure 6.1.2.2-1: Solution AppPackage App Development Lifecycle** + +The Solution AppPackage is used to convey the Solution App through the onboarding process to the Service Provider. It begins by pulling the App out of its repository and placing it in the package as mandated by the exchange requirements. Next security is applied such that the Service Provider can ensure that an Onboarded AppPackage did in fact come from the expected Solution Provider. The secure package, Solution AppPackage, is then delivered to the Service Provider for onboarding. + +### 6.1.3 App Onboarding Lifecycles + +The App Onboarding phase deals with establishing configuration, policies, measurements, and required analytics. The App Onboarding Phase is involved with both AppPackages and Apps, each with its own steps and associated actions. These are treated separately below. + +#### 6.1.3.1 Onboarded AppPackage Lifecycles + +The Service Design steps associated with an Onboarded AppPackage are shown below: + +![Figure 6.1.3.1-1: Onboarded AppPackage Service Provider Configuration Lifecycle. A flow diagram showing the process: Marketplace -> onboard -> verify -> unpack -> delete -> End. A feedback loop exists from [invalid] back to Marketplace via feedback.](3aff65ff46ea58154efa7094a028795c_img.jpg) + +``` + +graph LR + Marketplace[Marketplace] -- onboard --> S1(( )) + S1 -- verify --> S2(( )) + S2 -- unpack --> S3(( )) + S3 -- delete --> End(( )) + S2 -- "[invalid]" --> S4(( )) + S4 -- feedback --> Marketplace + +``` + +Figure 6.1.3.1-1: Onboarded AppPackage Service Provider Configuration Lifecycle. A flow diagram showing the process: Marketplace -> onboard -> verify -> unpack -> delete -> End. A feedback loop exists from [invalid] back to Marketplace via feedback. + +**Figure 6.1.3.1-1: Onboarded AppPackage Service Provider Configuration Lifecycle** + +An AppPackage is onboarded from the exchange, and its content verified. If valid, its contents (the App) are unpacked and the Onboarded AppPackage and associated Onboarded App are catalogued. If invalid, the Service Provider may provide AppPackage-level feedback to the Solution Provider via the Marketplace. + +O-RAN.TS.WG10.OAM-Architecture-R004-v14.00 + +![O-RAN ALLIANCE Logo](4526e42435746ac140b8391e2c984873_img.jpg) + +### 6.1.3.2 Onboarded App Lifecycles + +The App Onboarding Phase for Onboarded Apps is split between normal processing for all applications, named "Configuration", and the lifecycle for "Training" Apps with included AI/ML Models. Workflow can interchange between these cycles iteratively. Each of these is treated separately below. + +Note: The Run Time Library shown in the clauses below models a location where apps/Artifacts can be identified as ready for future deployment. It is not intended to imply any particular method of implementation of the SMO. + +#### 6.1.3.2.1 Onboarded App Certification Lifecycle + +The Service Operator Certification steps associated with an Onboarded App are shown below: + +![Onboarded App Service Provider Certification Lifecycle Diagram](934ff10062eea913a97aeae3a566f93d_img.jpg) + +**Diagram Description:** The diagram illustrates the certification lifecycle of an onboarded app. It shows interactions between the 'Marketplace', 'Catalogue', 'Service Planning' cloud/system, and 'Run-Time Library'. + +- Marketplace** (on the left) sends 'feedback (fix requests)' and 'feedback (feature requests)' to the **Service Planning** block. +- Catalogue** (top left) triggers a 'certify' loop back to itself. It also has 'Catalogue Changes' pointing to **Service Planning**. +- From **Catalogue**, there is a flow to **Service Planning** labeled '[initial config or training required] request change'. +- From **Service Planning**, there is a flow back to **Catalogue** labeled '[fail] request change'. +- From **Service Planning**, there is a flow to **Run-Time Library** (top right) labeled '[pass, w/suggested changes] publish'. +- Service Planning** also interacts with external entities: 'request change (rAPP)' and 'request change (xAPP)' on the right, and '[from training]' / '[to training]' at the bottom. + +Onboarded App Service Provider Certification Lifecycle Diagram + +**Figure 6.1.3.2.1-1 Onboarded App Service Provider Certification Lifecycle** + +Onboarded Apps are made visible in the SMO environment when published into the catalogue. Each recommended configuration of the App is certified prior to publication to a runtime library. If Certification fails, then Service Planning determines the next course of action. + +Service Planning aggregates "fix" requests from Configuration which may be passed back to the Solution Provider (at the AppPackage level) as feedback across the SP interface of the Marketplace Exchange. This exchange also aggregates "change" requests from Configuration or Operations and determines if the request is for additional development (a "feature" request) or additional training (a "training" request). The former would be aggregated and passed back to the Solution Provider via the SP interface as described above for "fix" requests. For the latter, the Service Design: Training lifecycle would ensue. + +If the Onboarded App requires AI/ML training, then a request through Service Planning is used to train the model. When the "Specialized App" is returned, like non-ML Onboarded Apps it is catalogued and scheduled for certification. Once certified the App is distributed as a Published App to a Run Time Library. From there operations can deploy as either a management (rApp) or network application instance (xApp). + +#### 6.1.3.2.2 App Training Lifecycle + +The Service Operator Training Lifecycle associated with a Training App is shown below: + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 55 + +![Figure 6.1.3.2.2-1: Training App Service Provider Training Lifecycle. The diagram shows a cyclic process. At the top is a box labeled 'Service Planning'. Below it is a horizontal sequence of four blue circles: 'groom training data', 'train application', 'validate model', and 'promote model'. A curved arrow labeled 'schedule resources' goes from 'Service Planning' to 'groom training data'. A curved arrow labeled 'promote model' goes from 'promote model' back to 'Service Planning'. A long curved arrow labeled 'additional training required' loops back from 'validate model' to 'groom training data'.](8d63dd406ef258f41f2c89fb636dfd28_img.jpg) + +Figure 6.1.3.2.2-1: Training App Service Provider Training Lifecycle. The diagram shows a cyclic process. At the top is a box labeled 'Service Planning'. Below it is a horizontal sequence of four blue circles: 'groom training data', 'train application', 'validate model', and 'promote model'. A curved arrow labeled 'schedule resources' goes from 'Service Planning' to 'groom training data'. A curved arrow labeled 'promote model' goes from 'promote model' back to 'Service Planning'. A long curved arrow labeled 'additional training required' loops back from 'validate model' to 'groom training data'. + +**Figure 6.1.3.2.2-1: Training App Service Provider Training Lifecycle** + +When a training request is received then resources within the training environment are scheduled for the application. Data is collected and groomed for training after which a training iteration is executed. At the end of the training cycle a test set is applied to the model and accuracy is calculated. If the test fails or other metadata indicates more training iterations are required, then the cycle repeats. Once the model is adequately trained it is promoted and sent back to service planning for continuation in another lifecycle. + +Inside the “Training Lifecycle” the process may require multiple iterations of training before being returned to the Service Planning MMP. + +The iteration count is included in the specialization metadata information. + +### 6.1.4 App Operation Lifecycles + +There can be many runtime environments in the service providers’ network. Some can be production while others can be for non-production execution, such as offline training and lab certification. This document focuses on the runtime aspects of rApps, which execute within the Non-RT RIC as part of the SMO, and xApps, which execute in the near-RT RIC as part of the RAN. Although they have the same lifecycle steps the data demands due to their operational environment are different and therefore are independently addressed. + +#### 6.1.4.1 App Instance Lifecycles + +![Figure 6.1.4.1-1: Service Provider Runtime Lifecycles. The diagram shows two parallel horizontal flows for rApp (purple) and xApp (yellow). Both flows start with 'Deploy' (rApp/xApp) and 'Run-Time Library' (rApp/xApp). The flows are: Deploy(rApp) -> monitor(rApp) -> Ops&mgt (rApp) -> Heal & scale (rApp) -> Recommend Changes(rApp). Similarly for xApp: Deploy(xApp) -> monitor(xApp) -> Ops&mgt (xApp) -> Heal & scale (xApp) -> Recommend Changes(xApp). A vertical bar on the right is labeled 'Service Planning'. A 'terminate (rApp)' arrow points from 'Heal & scale (rApp)' to a black circle, and a 'terminate (xApp)' arrow points from 'Heal & scale (xApp)' to the same black circle.](64513b61d6ee4d1816ca797a5d8c4181_img.jpg) + +Figure 6.1.4.1-1: Service Provider Runtime Lifecycles. The diagram shows two parallel horizontal flows for rApp (purple) and xApp (yellow). Both flows start with 'Deploy' (rApp/xApp) and 'Run-Time Library' (rApp/xApp). The flows are: Deploy(rApp) -> monitor(rApp) -> Ops&mgt (rApp) -> Heal & scale (rApp) -> Recommend Changes(rApp). Similarly for xApp: Deploy(xApp) -> monitor(xApp) -> Ops&mgt (xApp) -> Heal & scale (xApp) -> Recommend Changes(xApp). A vertical bar on the right is labeled 'Service Planning'. A 'terminate (rApp)' arrow points from 'Heal & scale (rApp)' to a black circle, and a 'terminate (xApp)' arrow points from 'Heal & scale (xApp)' to the same black circle. + +**Figure 6.1.4.1-1: Service Provider Runtime Lifecycles** + +After the App Instance is created through a deploy operation it is monitored. As monitoring reports the health and workload of the application it is scaled up and down based on demand. Based on monitoring result, a series of operation and management functions are triggered, such as alert management, event management, incident management and further analysis. The analysis results can provide guidance for further actions such as termination, healing and scaling. Finally, when its job is completed, the instance is terminated. While in operation the service provider may discover + +defects, performance issues, or identify new features that would be beneficial. Such issue or change request is communicated to the Service planning where the Application can be retrained or updated. The information may also be sent via the Service Planning to the Solution Provider as feedback. + +Operations determine when an application is deployed, or undeployed. Since applications are atomic, the update process is an orchestrated process of deploy and terminate. It is possible for two versions to be active at the same time, but care should be given not to provide overlapping scopes to the application instances, otherwise they may give differing directives to the network in a random order. This can cause a destabilization of the network. + +## 6.2 Common Application Lifecycle Conclusions + +The initial conclusion of Common Application Lifecycle procedures is that there is a formalized exchange between the Solution Provider and the Service Provider, the “SP Exchange”. The SP Exchange consists of data describing the package and its security. The package also contains information regarding Deployment Configurations, Application Types, Deployable Components, and potentially ML Models. Further details regarding the composition of these areas are defined through analysis of the Actions identified in clause 6.1 as an action requiring further analysis (Bolded). O-RAN use cases for App Operation Lifecycle actions beyond “Deploy” have not been specified. Therefore, the analysis of the App Operation Lifecycles has been limited to the “Deploy” action. + +The analysis consists of identifying the actors within the LCM which need information. Each Information Object is then analyzed for the Actions identified above and what is needed by each actor is identified. The actor information requirements are then be coalesced into artifacts such that each artifact is only be consumed by one actor. This maintains a separation of concern regarding artifact composition for different consumers. + +### 6.2.1 Information Consumers + +The following actors are used in the analysis as consumers of information. The CNAD is unique in that it is also the producer of all the artifacts used to convey the information. However, since this is a basic premise it is not used in the analysis to describe its role in artifact generation. + +| Actor | Role | Description | +|-------------|------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| CNAD | Cloud Native Application Developer | Vendor who wants to develop a CNA to be deployed into an O-RAN network utilizing CMT provided by a CP which in onboarded and deployed by the SMO. | +| CMT | Container Management Technology | Technology such as HELM® and/or Kubernetes® used to manage network functions components using cloud native de facto standards. This is different from the CP as the same CMT might be provided by different CPs.

NOTE: HELM and Kubernetes are registered trademarks/service marks of the Linux Foundation, in the United States and other countries. O-RAN is not affiliated with, endorsed or sponsored by the Linux Foundation. | +| CP | Cloud Provider | Cloud provider which provides cloud services including CMT. The exact mechanism or service points to provide the CMT may be cloud specific. This is different than the CMT as a CP can provide multiple CMT. | +| SMO | Service Management & Orchestration | This is the main orchestrator for a Telecom Service Provider to onboard and provide lifecycle management of vendor products. | +| RTE | Near-RT/Non-RT RIC | The near-RT RIC and Non-RT RIC provide the ability to be extended by 3 rd party xApps and rApps, respectively. To integrate these apps into its framework a descriptor is supplied to its Run Time Environment (RTE). | + +### 6.2.2 Solution SW Package Lifecycle + +The Solution SW package lifecycle deals with the Solution Provider creating a secure package that can be delivered to a Service Operator for onboarding. This largely deals with the addition of all the artifacts of the software into a library and then adding security around the files and the package. Annex clause C.1 describes the processing of the artifacts into the package. + +#### 6.2.2.1 Functional Requirements + +| REQ | Description | Note | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| [REQ-ALM-FUN2-1] | The Application Package shall be composed of at least all the mandatory items defined in the Application Package Descriptor and its subtending elements. | | +| [REQ-ALM-FUN2-2] | The Application Package shall support security requirements as specified in SecReqSpecs [4]. | | + +### 6.2.3 Onboarded SW Package Lifecycles + +The Onboarded SW Package Lifecycles deal with the importing of an Application Package by first verifying its authenticity and then verifying its consistency. Assuming the package passes those tests the contained artifacts are extracted from the package and added to the SMO catalogue. Annex clause C.2 describes the process of cataloguing the artifacts of the package. + +#### 6.2.3.1 Functional Requirements + +| REQ | Description | Note | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------|------| +| [REQ-ALM-FUN3-1] | The SMO shall have the capability to verify that Application Package satisfies security requirements as specified in SecReqSpecs [4]. | | +| [REQ-ALM-FUN3-2] | The SMO shall verify that the values contained in the Application Package descriptors are valid prior to cataloguing. | | +| [REQ-ALM-FUN3-3] | The SMO shall catalogue the verified artifacts identified in the Application Package. | | + +### 6.2.4 Onboarded ManagementDescriptor Certification Lifecycle + +The Onboarded ManagementDescriptor Certification Lifecycle entails certifying deployment options prior to utilization in a specific runtime environment. The SMO initiates the fine tuning of such an App for this deployment option. This process may be iterative, and the SMO identifies each refinement of the App and certifies the refinements results in the App being suitable for inclusion in the run time library for deployment. Annex clause C.3 describes the process of certifying a deployment option of the package. + +#### 6.2.4.1 Functional Requirements + +| REQ | Description | Note | +|------------------|--------------------------------------------------------------------------------------------------------------------|------| +| [REQ-ALM-FUN4-1] | The SMO should validate and certify each deployment option defined in the application package prior to deployment. | | +| [REQ-ALM-FUN4-2] | SMO shall be able to identify a deployment option that requires AI/ML training and initiate the training request. | | + +| | | | +|------------------|----------------------------------------------------------------------------------------------------------------------------|--| +| [REQ-ALM-FUN4-3] | SMO shall be able to identify and onboard a new version of an App for a specific deployment delivered from AI/ML Training. | | +|------------------|----------------------------------------------------------------------------------------------------------------------------|--| + +### 6.2.5 Application Training Lifecycle + +The Application Training Lifecycle deals with the training of an AI/ML Model that was included as part of a deployment option in an application package. The model is trained, and the resultant deployment is returned as a new version of the application. Annex clause C.4 describes the process of training an application deployment option which contains one or more ML Models. + +#### 6.2.5.1 Functional Requirements + +| REQ | Description | Note | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| [REQ-ALM-FUN5-1] | The Training Provider shall have the ability to receive training requests. (Note 1) | | +| [REQ-ALM-FUN5-2] | Training Platform shall acquire the data from the network which satisfy the Data Requirements specified in the MLModelDescriptor. (Note 1) | | +| [REQ-ALM-FUN5-3] | The Training Provider shall be able to validate that the model has been trained sufficiently, such as passing accuracy thresholds for use in a production setting. (Note 1) | | +| [REQ-ALM-FUN5-4] | The Training Provider shall deliver an updated version of the App for the specified deployment option in the format that the SMO can onboard. | | + +**Note 1: This requirement is overarching and generalized in nature. Specific requirements for rApps or xApps as specified by other Work Groups shall supersede this requirement when in conflict.** + +### 6.2.6 Deploy Instance Lifecycle + +Deployment of an Application differs only slightly depending on if it is a CNF, xApp, or rApp. Basically, the process of registering with a Run Time Environment is not required when the application is a CNF. The xApp and rApp differ in the registration process and the mechanisms to connect the Application with other Applications of the same type is dependent on the framework used. + +The use case for CNF deployment is in CLD-ORCH-UC [i.8], clause 3.2.1. The use case for xApp deployment is in CLD-ORCH-UC [i.8], clause 3.3.2. An example use case for deployment of an rApp is in Annex C.5 of this document. + +#### 6.2.6.1 Functional Requirements + +| REQ | Description | Note | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------|------| +| [REQ-ALM-FUN6-1] | The SMO shall be able to deploy a CNF using a set of CloudNativeDescriptorFiles and a set of OverrideVariables as defined in the DeploymentItem. | | +| [REQ-ALM-FUN6-2] | The SMO shall be able to deploy an xApp using a set of CloudNativeDescriptorFiles and a set of OverrideVariables as defined in the DeploymentItem. | | +| [REQ-ALM-FUN6-3] | The SMO should be able to deploy an rApp using a set of CloudNativeDescriptorFiles and a set of OverrideVariables as defined in the DeploymentItem. | | + +# Annex A (informative): Cardinality + +This informative Annex provides background information regarding the cardinality of different O-RAN architecture elements. It is not intended as a requirement on cardinality. + +The RAN network has an expected hierarchical fan out. Therefore, the O-RAN sizing would be: + +- Non-RT RIC (1..j) +- Near-RT RIC (1..k) +- O-CU-CP (1..m) +- O-CU-UP (1..n) +- O-DU (1..p) +- O-RU (1..q) + +Where: $1 \leq j$ ; $j \leq k$ ; $k \leq m$ ; $m \leq n$ ; $m \leq p$ ; $p \leq q$ + +Due to resiliency and scaling aspects of cloud implementations an O-DU will logically be connected to one O-CU-CP. The O-CU-CP may in fact be a pool of O-CU-CP instances to handle loads. + +O-CU-UP NFs will be pooled and aligned with the services they are configured to serve. The O-CU-CP will assign the O-CU-UP that an O-DU needs to connect to for a given UE session. + +An O-DU may serve many O-RU NFs depending on its designed capacity to manage the loop 1 processing. + +One Near-RT RIC will be connected to multiple O-CU-CP, O-CU-UP, and O-DU NFs. For resiliency the NFs may be connected to more than one Near-RT RIC, however, it shall not require duplication of data to be sent to each RIC instance. + +A Near-RT RIC will be connected to one non-RT RIC. + +# --- Annex B: Void + +# Annex C (informative): Common App Lifecycle Flows + +This clause provides examples of information flow during various lifecycle activities which are not depicted in other O-RAN Specifications. + +## C.1 Solution SW Package Lifecycle + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Build a package that a CNAD can deliver to an Operator which can be onboarded onto the SMO. | | +| Actors and Roles | [1]. Cloud Native Application Developer
[2]. Application Package. | | +| Assumptions | [1]. The application has been successfully verified by the developer
[2]. The order in which the artifacts are added are arbitrary and can be done in any order. The order presented is just one of many possible orders. | | +| Pre-conditions | [1]. Developer Repository is available and contains the unpackaged artifacts. | | +| Begins when | CNAD wants to create an Application Package for delivery to the operator. | | +| Step 1 (M) | Add the CMDictionary files to the package. | | +| Step 2 (O) | Add the certificates which are to be delivered with the package to the package. | | +| Step 3 (M) | Add the ManagementDescriptor to the Package | | +| Step 4 (M) | Add the ExecutableImages to the Package | | +| Step 5 (O) | Add the RTEDescriptor if an rApp or xApp to the Package | | +| Step 6 (M) | Add the ComponentDescriptor to the Package | | +| Step 7 (O) | Add the MLModelDescriptor to the Package | | +| Step 8 (O) | Add any Training History for the MLModel to the Package | | +| Step 9 (O) | Add the CloudNativeDescriptor to the Package | | +| Step 10 (O) | Add the DeploymentDescriptor to the Package | | +| Step 11 (M) | Compute the Checksum for all files in the Package and add to Package | | +| Step 12 (M) | Digitally Sign the Package | | +| Ends when | The Application Package is Created. | | +| Exceptions | None identified | | +| Post Conditions | Application is described in a secure Application Package. | | +| Traceability | [REQ-ALM-FUN01]; [REQ-ALM-FUN02]; [REQ-ALM-FUN03] | | + +![Sequence diagram showing the process of adding files to an application package and signing it. The diagram involves a Personnel (Cloud Network Application Developer - CNAD) and an Application Package (PACK). The process includes adding configuration files, certificates, executable images, RTE descriptors, ML model descriptors, and deployment descriptors, followed by adding a checksum and signing the package.](d32216ae53712b6faab76d5e0690d94c_img.jpg) + +``` + +sequenceDiagram + participant Personnel as Personnel +Cloud Network +Application Developer +(CNAD) + participant ApplicationPackage as Application Package + participant PACK as PACK + + loop [foreach ConfigurationManagementDescriptionFile] + Personnel->>ApplicationPackage: 1 Add File to Package + Note over ApplicationPackage: Update ManagementDescriptor.ConfigurationDictionary with filename and filetype + end + + loop [foreach Certificate] + Personnel->>ApplicationPackage: 2 Add File to Package + Note over ApplicationPackage: Update ManagementDescriptor.SecurityDescriptor.Certificate with filename + end + + Personnel->>ApplicationPackage: 3 Add Management Descriptor + + loop [foreach Component of the App] + Personnel->>ApplicationPackage: 4 Add ExecutableImage + Note over ApplicationPackage: Update Component Descriptor with CloudNativeFileNames + alt [if rApp or xApp Component then] + Personnel->>ApplicationPackage: 5 Add RTE Descriptor + Note over ApplicationPackage: Update ComponentDescriptor with RTEDescriptorFileName + end + Personnel->>ApplicationPackage: 6 Add **Component Descriptor + end + + alt [if ML Enabled] + Personnel->>ApplicationPackage: 7 ML Model Descriptor(s) + alt [If Training has been performed then] + Personnel->>ApplicationPackage: 8 Add ML Training History + end + end + + loop [For each Deployment Option] + loop [For each Deployment Module] + Personnel->>ApplicationPackage: 9 add CloudNative Descriptor + Note over ApplicationPackage: Update Deployment Descriptor with CloudNativeFileNames + end + Personnel->>ApplicationPackage: 10 Add Deployment Descriptor + end + + Personnel->>ApplicationPackage: 11 Add Checksum for artifacts + Personnel->>ApplicationPackage: 12 Sign Overall Package + + ApplicationPackage-->>Personnel: Cloud Network Application Developer (CNAD) + +``` + +The diagram illustrates the process of adding files to an application package and signing it. The process involves a Personnel (Cloud Network Application Developer - CNAD) and an Application Package (PACK). The process is divided into two main sections: PACK and SECURE. + +**PACK Section:** + +- Loop [foreach ConfigurationManagementDescriptionFile]:** + - 1 Add File to **Package** + - Update **ManagementDescriptor.ConfigurationDictionary** with filename and filetype +- Loop [foreach Certificate]:** + - 2 Add File to **Package** + - Update **ManagementDescriptor.SecurityDescriptor.Certificate** with filename +- 3 Add **Management Descriptor** +- Loop [foreach Component of the App]:** + - 4 Add **ExecutableImage** + - Update **Component Descriptor** with **CloudNativeFileNames** + - alt [if rApp or xApp Component then]:** + - 5 Add **RTE Descriptor** + - Update **ComponentDescriptor** with **RTEDescriptorFileName** + - 6 Add **\*\*Component Descriptor** +- alt [if ML Enabled]:** + - 7 **ML Model Descriptor(s)** + - alt [If Training has been performed then]:** + - 8 Add **ML Training History** +- Loop [For each Deployment Option]:** + - Loop [For each Deployment Module]:** + - 9 add **CloudNative Descriptor** + - Update **Deployment Descriptor** with **CloudNativeFileNames** + - 10 Add **Deployment Descriptor** + +**SECURE Section:** + +- 11 Add Checksum for artifacts +- 12 Sign Overall Package + +The diagram concludes with the Cloud Network Application Developer (CNAD) and the Application Package (PACK) being updated. + +Sequence diagram showing the process of adding files to an application package and signing it. The diagram involves a Personnel (Cloud Network Application Developer - CNAD) and an Application Package (PACK). The process includes adding configuration files, certificates, executable images, RTE descriptors, ML model descriptors, and deployment descriptors, followed by adding a checksum and signing the package. + + + +![Sequence diagram showing the process of creating and securing an Application Package. The diagram involves two main entities: Personnel (Cloud Network Application Developer (CNAD)) and Application Package. The process is divided into two main phases: PACK and SECURE. The PACK phase includes steps for adding files, updating descriptors, and adding descriptors. The SECURE phase includes steps for adding checksums and signing the package.](305f926956a1bab03d551c9bce1b8f24_img.jpg) + +``` + +sequenceDiagram + actor CNAD as Personnel +Cloud Network Application Developer (CNAD) + participant AP as Application Package + participant PACK + participant SECURE + + loop [foreach ConfigurationManagementDescriptionFile] + CNAD->>AP: 1 Add File to Package + Note right of AP: Update AppDescriptor.ConfigurationDictionary with filename and filetype + end + + loop [foreach Certificate] + CNAD->>AP: 2 Add File to Package + Note right of AP: Update AppDescriptor.SecurityDescriptor.Certificate with filename + end + + CNAD->>AP: 3 Add App Descriptor + + loop [foreach Component of the App] + CNAD->>AP: 4 Add DockerImage + Note right of AP: Update Component Descriptor with CloudNativeFileNames + alt [if rAPP or xAPP Component then] + CNAD->>AP: 5 Add RTE Descriptor + Note right of AP: Update ComponentDescriptor with RTEDescriptorFileName + end + CNAD->>AP: 6 Add **Component Descriptor + end + + alt [if ML Enabled] + CNAD->>AP: 7 ML Model Descriptor(s) + alt [If Training has been performed then] + CNAD->>AP: 8 Add ML Training History + end + end + + loop [For each Deployment Option] + loop [For each Deployment Module] + CNAD->>AP: 9 add CloudNative Descriptor + Note right of AP: Update Deployment Descriptor with CloudNativeFileNames + end + CNAD->>AP: 10 Add Deployment Descriptor + end + + SECURE + + CNAD->>AP: 11 Add Checksum for artifacts + CNAD->>AP: 12 Sign Overall Package + +``` + +The diagram illustrates the process of creating and securing an Application Package. It involves two main entities: Personnel (Cloud Network Application Developer (CNAD)) and Application Package. The process is divided into two main phases: PACK and SECURE. + +**PACK Phase:** + +- Loop [foreach ConfigurationManagementDescriptionFile]:** + - 1 Add File to **Package** + - Update **AppDescriptor.ConfigurationDictionary** with filename and filetype +- Loop [foreach Certificate]:** + - 2 Add File to **Package** + - Update **AppDescriptor.SecurityDescriptor.Certificate** with filename +- 3 Add **App Descriptor** +- Loop [foreach Component of the App]:** + - 4 Add **DockerImage** + - Update **Component Descriptor** with **CloudNativeFileNames** + - alt [if rAPP or xAPP Component then]:** + - 5 Add **RTE Descriptor** + - Update **ComponentDescriptor** with **RTEDescriptorFileName** + - 6 Add **\*\*Component Descriptor** +- alt [if ML Enabled]:** + - 7 **ML Model Descriptor(s)** + - alt [If Training has been performed then]:** + - 8 Add **ML Training History** +- Loop [For each Deployment Option]:** + - Loop [For each Deployment Module]:** + - 9 add **CloudNative Descriptor** + - Update **Deployment Descriptor** with **CloudNativeFileNames** + - 10 Add **Deployment Descriptor** + +**SECURE Phase:** + +- 11 Add Checksum for artifacts +- 12 Sign Overall Package + +Sequence diagram showing the process of creating and securing an Application Package. The diagram involves two main entities: Personnel (Cloud Network Application Developer (CNAD)) and Application Package. The process is divided into two main phases: PACK and SECURE. The PACK phase includes steps for adding files, updating descriptors, and adding descriptors. The SECURE phase includes steps for adding checksums and signing the package. + +## C.2 Onboarded SW Package Lifecycle + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Verify and Unpack a package that a CNAD delivered to an Operator which is placed in the SMO catalogue. | | +| Actors and Roles | [1]. Cloud Native Application Developer
[2]. Service Designer.
[3]. SMO Import Function.
[4]. SMO Catalogue. | | +| Assumptions | [1]. The Application Package has been successfully received from the CNAD.
[2]. The order in which the artifacts are extracted is arbitrary and can be done in any order. The order presented is just one of many possible orders. | | +| Pre-conditions | [1]. Catalogue is available. | | +| Begins when | Service Designer wants onboard and catalog a package received from the CNAD. | | +| Step 1-2 (M) | Get the package to Import and begin Import | | +| Step 3-5 (M) | Verify the Signature of the Package | | +| Step 6-8 (M) | Verify the checksum of all artifacts in the package. | | +| Step 9 (O) | Add the package to the catalogue. | | +| Step 10 (M) | Extract the overall Application Package Descriptor | | +| Step 11-12 (M) | Extract and Catalogue all ConfigurationManagementDescriptionFile | | +| Step 13-14 (M) | Extract and Catalogue all Certificates | | +| Step 15-16 (M) | Extract and Catalogue all ExecutableImages | | +| Step 17-18 (M) | Extract and Catalogue all RTEDescriptor Files | | +| Step 19 (M) | Catalogue the ManagementDescriptor | | +| Step 20-21 (M) | Extract and Catalogue all MLModelDescriptors | | +| Step 22 (M) | Extract each DeploymentDescriptor | | +| Step 23-24 | Extract and Catalogue each CloudNativeDescriptorFile | | +| Step 25 (M) | Catalogue each DeploymentDescriptor | | +| Step 26 (M) | Return success of the Package Import request. | | +| Ends when | The information elements of the Application Package have been successfully added to the catalogue. | | +| Exceptions | 1) Package fails signature verification. Feedback is sent to CNAD. Use Case Terminates.
2) File fails Checksum validation. Feedback is sent to CNAD. Use Case Terminates. | | +| Post Conditions | Application is described the SMO catalogue. | | +| Traceability | [REQ-ALM-FUN04]; [REQ-ALM-FUN05]; [REQ-ALM-FUN06] | | + +![Sequence diagram for Application Package Onboarding and Cataloging. The diagram shows interactions between Personnel (Cloud Native Application Developer (CNAD) and Service Designer (SMO)), Application Package, Service Management & Orchestration Framework (Import Function and Catalog), and various processing steps like Management Descriptor Processing, ML Mode Descriptor Processing, and Deployment Descriptor Processing.](908e7621c8c152222146c02caeedd457_img.jpg) + +``` + +sequenceDiagram + participant AP as Application Package + participant Personnel as Personnel + participant CNAD as Cloud Native Application Developer (CNAD) + participant SMO as Service Designer (SMO) + participant SMOF as Service Management & Orchestration Framework + participant IF as Import Function + participant Catalog as Catalog + + Note over Personnel: VERIFY + Personnel->>AP: 1 Fetch + AP->>SMOF: 2 Onboard (ApplicationPackage) + SMOF->>Personnel: 3 Authenticate Signature + alt [If Authentication Fails] + SMOF->>Personnel: 4 Terminate Processing and Indicate Authentication Failure + Personnel->>AP: 5 Send Feedback (fix request) + else [If Verification Fails] + SMOF->>Personnel: 7 Terminate Processing and Indicate File Corruption + Personnel->>AP: 8 Send Feedback (fix request) + end + SMOF->>Catalog: 9 Add Package to Catalogue + + Note over Personnel: UNPACK + Personnel->>SMOF: 10 Get Management Descriptor + loop [foreach ConfigurationManagementDescriptorFile in Management Descriptor] + SMOF->>Personnel: 11 Extract File + Personnel->>SMOF: 12 Add File + Note over SMOF: Update for local file names + end + loop [foreach Certificate in Management Descriptor] + SMOF->>Personnel: 13 Extract File + Personnel->>SMOF: 14 Add File + Note over SMOF: Update for local file names + end + loop [foreach ExecutableImage in Management Descriptor] + SMOF->>Personnel: 15 Extract File + Personnel->>SMOF: 16 Add File + Note over SMOF: Update for local file names + end + loop [foreach RTEDescriptor in Management Descriptor] + SMOF->>Personnel: 17 Extract File + Personnel->>SMOF: 18 Add File + Note over SMOF: Update for local file names + end + SMOF->>Catalog: 19 Catalogue Management Descriptor + + Personnel->>SMOF: 20 Get ML Model + SMOF->>Catalog: 21 Catalogue ML Model + + Personnel->>SMOF: 22 Get DeploymentDescriptor + loop [foreach CloudNativeDescriptorFile in Application Package"] + SMOF->>Personnel: 23 Extract File + Personnel->>SMOF: 24 Add File + Note over SMOF: Update for local file names + end + SMOF->>Catalog: 25 Catalogue Deployment Descriptor + + SMOF->>Personnel: 26 Success: Package Catalogued. + +``` + +The diagram illustrates the process of onboarding and cataloging an application package. It involves two main phases: **VERIFY** and **UNPACK**. + +**VERIFY Phase:** + +- 1 Fetch:** The Application Package is fetched. +- 2 Onboard (ApplicationPackage):** The package is onboarded to the Service Management & Orchestration Framework. +- 3 Authenticate Signature:** The framework authenticates the signature. +- 4 Terminate Processing and Indicate Authentication Failure:** If authentication fails, processing is terminated. +- 5 Send Feedback (fix request):** Feedback is sent to the Application Package. +- 6 verify checksums:** Checksums are verified. +- 7 Terminate Processing and Indicate File Corruption:** If verification fails, processing is terminated. +- 8 Send Feedback (fix request):** Feedback is sent to the Application Package. +- 9 Add Package to Catalogue:** The package is added to the Catalog. + +**UNPACK Phase:** + +- 10 Get Management Descriptor:** The Management Descriptor is retrieved. +- 11 Extract File:** Files are extracted from the Management Descriptor. +- 12 Add File:** Files are added to the local storage. +- 13 Extract File:** Files are extracted from the Management Descriptor. +- 14 Add File:** Files are added to the local storage. +- 15 Extract File:** Files are extracted from the Management Descriptor. +- 16 Add File:** Files are added to the local storage. +- 17 Extract File:** Files are extracted from the Management Descriptor. +- 18 Add File:** Files are added to the local storage. +- 19 Catalogue Management Descriptor:** The Management Descriptor is catalogued. +- 20 Get ML Model:** The ML Model is retrieved. +- 21 Catalogue ML Model:** The ML Model is catalogued. +- 22 Get DeploymentDescriptor:** The DeploymentDescriptor is retrieved. +- 23 Extract File:** Files are extracted from the DeploymentDescriptor. +- 24 Add File:** Files are added to the local storage. +- 25 Catalogue Deployment Descriptor:** The DeploymentDescriptor is catalogued. +- 26 Success: Package Catalogued:** The process is successful. + +Sequence diagram for Application Package Onboarding and Cataloging. The diagram shows interactions between Personnel (Cloud Native Application Developer (CNAD) and Service Designer (SMO)), Application Package, Service Management & Orchestration Framework (Import Function and Catalog), and various processing steps like Management Descriptor Processing, ML Mode Descriptor Processing, and Deployment Descriptor Processing. + + + +![Sequence diagram showing the process of importing an application package into the Service Management & Orchestration Framework. The diagram involves Personnel (Cloud Native Application Developer (CNAD) and Service Designer (SMO)) and the Service Management & Orchestration Framework (Import Function and Catalog). The process includes steps for Fetch, Onboard, Authenticate Signature, Verify, Unpack, and Catalogue.](d283d0be8a577dc21df69b620d4ed224_img.jpg) + +``` + +sequenceDiagram + participant Personnel + participant CNAD as Cloud Native Application Developer (CNAD) + participant SMO as Service Designer (SMO) + participant ImportFunction as Import Function + participant Catalog as Catalog + + Note over Personnel: Application Package + Note over ImportFunction: Service Management & Orchestration Framework + + Personnel->>ImportFunction: 1 Fetch + ImportFunction->>Personnel: 2 Onboard (ApplicationPackage) + ImportFunction->>Personnel: 3 Authenticate Signature + alt [If Authentication Fails] + ImportFunction->>Personnel: 4 Terminate Processing and Indicate Authentication Failure + Personnel->>ImportFunction: 5 Send Feedback (fix request) + else [If Verification Fails] + ImportFunction->>Personnel: 7 Terminate Processing and Indicate File Corruption + Personnel->>ImportFunction: 8 Send Feedback (fix request) + end + ImportFunction->>Personnel: 6 verify checksums + ImportFunction->>Catalog: 9 Add Package to Catalogue + + Note over Personnel: App Descriptor Processing + Personnel->>ImportFunction: 10 Get App Descriptor + loop [foreach ConfigurationManagementDescriptionFile in App Descriptor] + Personnel->>ImportFunction: 11 Extract File + ImportFunction->>Catalog: 12 Add File + Note over Catalog: Update for local file names + end + loop [foreach Certificate in App Descriptor] + Personnel->>ImportFunction: 13 Extract File + ImportFunction->>Catalog: 14 Add File + Note over Catalog: Update for local file names + end + loop [foreach DockerImage in App Descriptor] + Personnel->>ImportFunction: 15 Extract File + ImportFunction->>Catalog: 16 Add File + Note over Catalog: Update for local file names + end + loop [foreach RTEDescriptor in App Descriptor] + Personnel->>ImportFunction: 17 Extract File + ImportFunction->>Catalog: 18 Add File + Note over Catalog: Update for local file names + end + ImportFunction->>Catalog: 19 Catalogue App Descriptor + + Note over Personnel: ML Mode Descriptor Processing + loop [foreach ML Model in Application Package] + Personnel->>ImportFunction: 20 Get ML Model + ImportFunction->>Catalog: 21 Catalogue ML Model + end + + Note over Personnel: Deployment Descriptor Processing + Personnel->>ImportFunction: 22 Get DeploymentDescriptor + loop [foreach CloudNativeDescriptorFile in Application Package**] + Personnel->>ImportFunction: 23 Extract File + ImportFunction->>Catalog: 24 Add File + Note over Catalog: Update for local file names + end + ImportFunction->>Catalog: 25 Catalogue Deployment Descriptor + + ImportFunction->>Personnel: 26 Success: Package Catalogued. + +``` + +Sequence diagram showing the process of importing an application package into the Service Management & Orchestration Framework. The diagram involves Personnel (Cloud Native Application Developer (CNAD) and Service Designer (SMO)) and the Service Management & Orchestration Framework (Import Function and Catalog). The process includes steps for Fetch, Onboard, Authenticate Signature, Verify, Unpack, and Catalogue. + +## C.3 Onboarded ManagementDescriptor Certification Lifecycle + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Certify a deployment option for publication to a runtime library. | | +| Actors and Roles | [1]. Cloud Native Application Developer
[2]. Application Tester.
[3]. Service Planning.
[4]. SMO Catalogue.
[5]. SMO Runtime Library | | +| Assumptions | [1]. The deployment option has been onboarded. Some instruction for populating the runtime variables and application configuration has been provided. Currently this is outside the of the application package. | | +| Pre-conditions | [1]. Catalogue is available.
[2]. Certification Environment is available.
[3]. Runtime Library is available. | | +| Begins when | Service Designer wants to certify a deployment option. | | +| Step 1-3 (M) | Perform Certification Testing | | +| Step 3 (O) | Modify Configuration Parameters and re-iterate testing until complete. | | +| Step 4-6 (M) | Testing Complete. Extract Catalogue components for this option and publish to runtime library. | | +| Step 7-8 (O) | Exception Case 1: Certification failed due to feature defect. Notify CNAD of failed deployment certification. | | +| Step 9-13 (M) | Exception Case 2: Certification failed due to lack of training. Send to training and ingest trained model as new application version. | | +| Step 14 (M) | Exception Case 3: Unspecified Other Failure. | | +| Ends when | The deployment option is certified and published into a runtime library. | | +| Exceptions | 1) Deployment Option fails certification. Feedback is sent to CNAD. Use Case Terminates.
2) Deployment Option requires additional training. Use case resumes at Step 1 with the new version to be certified.
3) Other failure cases: Use Case Terminates and failure cause is corrected before restarting the Use Case at step 1. | | +| Post Conditions | Deployment Option is published in a Runtime Library. Note: The SMO can have several Runtime Libraries for different environments. | | +| Traceability | [REQ-ALM-FUN07]; [REQ-ALM-FUN08]; [REQ-ALM-FUN09] ; [REQ-ALM-FUN10] ; [REQ-ALM-FUN11] | | + +![Sequence diagram for Application Certification Process](747b8d456712a3f332d2adf596af295e_img.jpg) + +``` + +sequenceDiagram + participant Personnel as Personnel + participant SMO as Application Tester (SMO) + participant CNAD as Cloud Network Application Developer (CNAD) + participant CF as Certification Function + participant SP as Service Planning + participant Catalogue as Catalogue + participant RTL as Run Time Library + + Note over Personnel: [PERSONNEL] + Note over CF, SP, Catalogue, RTL: [SERVICE MANAGEMENT & ORCHESTRATION FRAMEWORK] + + Personnel->>CF: 1 Begin Testing + activate CF + CF->>CF: 2 Perform Certification Testing + CF-->>Personnel: + deactivate CF + + Note over CF: [CATALOG CHANGES] + alt [If Certification Fails due to Configuration then] + CF->>Catalogue: 3 Update Configuration Data for next Validation Iteration + Note over CF: The Initial recommended Configuration From the Package is not defined in the information model + else [If Certification Succeeds then] + CF->>Catalogue: 4 Fetch App Catalog Data + CF->>RTL: 5 Publish App Catalog Data to Run Time Library + end + + CF->>Personnel: 6 Certification Complete + deactivate CF + + alt [Certification Failed Due to Defect then] + CF->>Personnel: 7 Certification Failed (defect) + Personnel->>CF: 8 Feedback (fix requests) + else [Certification Failed Due to Training then] + CF->>SP: 9 Send to AI/ML Training + SP->>CF: 10 Certification Failed (training) + SP->>CF: 11 AI/ML Training Completed + SP->>Catalogue: 12 Establish New App Version to be Certified + SP->>Catalogue: 13 Update Training Record + else [Other Failure Detected] + CF->>Personnel: 14 Certification Failed (failure) + end + +``` + +The diagram illustrates the Application Certification Process, involving Personnel (Cloud Network Application Developer (CNAD) and Application Tester (SMO)) and the Service Management & Orchestration Framework (Certification Function, Service Planning, Catalogue, and Run Time Library). + +**Process Flow:** + +- 1 Begin Testing:** Personnel initiates the process. +- 2 Perform Certification Testing:** Certification Function performs the testing. +- CATALOG CHANGES:** + - [If Certification Fails due to Configuration then]:** Certification Function updates configuration data for the next validation iteration. A note indicates: "The Initial recommended Configuration From the Package is not defined in the information model". + - [If Certification Succeeds then]:** Certification Function fetches app catalog data and publishes it to the Run Time Library. +- 6 Certification Complete:** Certification Function notifies Personnel. +- [Certification Failed Due to Defect then]:** Certification Function notifies Personnel of a defect, and Personnel provides feedback (fix requests). +- [Certification Failed Due to Training then]:** Certification Function sends data to AI/ML Training, which then notifies Certification Function of training completion. Certification Function then establishes a new app version to be certified and updates the training record. +- [Other Failure Detected]:** Certification Function notifies Personnel of a failure. + +Sequence diagram for Application Certification Process + +## C.4 Application Training Lifecycle + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Train one or more ML models which are part of a deployment option for an application. | | +| Actors and Roles | [1]. Service Planning.
[2]. Training Provider | | +| Assumptions | [1]. The deployment option has been onboarded and an initial configuration for deployment has been identified. | | +| Pre-conditions | [1]. Training Provider is available.
[2]. Data required for training is available. | | +| Begins when | Service Planning requests a deployment option with at least one AI/ML Model to be trained. | | +| Step 1 (M) | Service Planning initiates a training request | | +| Step 2 (O) | Training Platform acquires the data from the network which satisfy the Data Requirements specified in the MLModelDescriptor. | | +| Step 3 (M) | The Training Platform executes the training iteration. | | +| Step 4 (M) | The Training Platform updates the training history record for the deployment option | | +| Step 5 (M) | The Training platform validates the ML Model scores to determine if it now ready to be certified. | | +| Step 6 (M) | The Training platform returns the newly trained version of the ML Model to Service Planning. | | +| Ends when | The ML Models of the deployment option successfully pass its qualification scores required for accuracy in a runtime environment. | | +| Exceptions | None Identified. | | +| Post Conditions | Deployment Option is returned to Service Planning as a new version of the application. | | +| Traceability | [REQ-ALM-FUN12]; [REQ-ALM-FUN13]; [REQ-ALM-FUN14]; [REQ-ALM-FUN15] | | + +![Sequence diagram showing the interaction between Service Management & Orchestration Framework and Training Provider for ML model training.](2912641e9a5b67b5775247d9f57de582_img.jpg) + +``` + +sequenceDiagram + participant SM as Service Management & Orchestration Framework + participant TP as Training Provider + participant SP as Service Planning + participant TP_Platform as Training Platform + + SM->>TP: 1 TrainingRequest (ML Models) + Note over SM: More than one model may need to be trained together + + loop [while Training] + TP_Platform->>TP_Platform: 2 Groom Training Data + Note over TP_Platform: Using the ML Model Descriptor training data requirements and ** Security requirements establish the collection of data to create The training, testing, and validation data sets. + + TP_Platform->>TP_Platform: 3 perform Training iteration + + TP_Platform->>TP_Platform: 4 Update Training History + TP_Platform->>TP_Platform: 5 Compare Metrics to Thresholds + Note over TP_Platform: Using the ML Model Descriptor performance requirements and the validation requirements determine if the model is sufficiently trained for operations. + + end + + TP-.->>SM: 6 Training Complete + +``` + +The diagram illustrates the ML model training lifecycle between the Service Management & Orchestration Framework (SM) and the Training Provider (TP). + +- Step 1:** The SM sends a **TrainingRequest (ML Models)** to the TP. A note indicates that more than one model may need to be trained together. +- Loop [while Training]:** + - Step 2:** The TP performs **Groom Training Data**. A note specifies using the **ML Model Descriptor training data requirements** and **Security requirements** to establish data collection for training, testing, and validation. + - Step 3:** The TP performs **perform Training iteration**. + - Step 4:** The TP updates **Training History**. + - Step 5:** The TP compares **Metrics to Thresholds**. + - A note indicates using the **ML Model Descriptor performance requirements** and **validation requirements** to determine if the model is sufficiently trained. +- Step 6:** The TP sends a **Training Complete** message back to the SM. + +Sequence diagram showing the interaction between Service Management & Orchestration Framework and Training Provider for ML model training. + +## C.5 Deploy rApp Instance Lifecycle + +| Use Case Stage | Evolution / Specification | <>
Related use | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | rApp deployment is instantiated on Non-RT RIC, resulting in enhanced capabilities. Configuration and communication between rApp and SMO is mediated by the Non-RT RIC via the R1 interface. | | +| Actors and Roles |
  • [1]. Operations Personnel
  • [2]. SMO (Run Time Library, Network Function Orchestrator, OAM Functions, Non-RT RIC, rApp)
  • [3]. O-Cloud (Deployment Management Services)
  • [4]. O-RAN (Any NF)
| | +| Assumptions |
  • [1]. The O-Cloud and resultant O2 interface are used to exemplify a cloud. Implementations may vary based on SMO architecture and deployment model.
  • [2]. The “Deployment Option” to the SMO for the new rApp(s) may include information for the SMO to use for homing purposes, such as desired rApp or rApp type(s) associated with O-Cloud or Non-RT RIC Instance
| | +| Pre-conditions |
  • [1]. SMO is available
  • [2]. The O-Cloud instance has been installed successfully as per “O-Cloud Deployment Processing” use case.
  • [3]. Non-RT RIC NF has been deployed successfully on the O-Cloud instance as part of the SMO.
  • [4]. rApp package has been onboarded onto the SMO. The Onboarded package has at least one deployment option that has been certified and published in the Run-Time Library per the Application Lifecycle. The NF package contains a descriptor that provides the deployment and resource requirements for the rApp
| | +| Begins when | New rApp is to be instantiated as a SMO deployment on a Non-RT RIC hosted on an O-Cloud | | +| Step 1-2 (M) | Ops Personnel query the Run Time Library to find certified deployment options for the rApp. This includes the Schema Variables for descriptor overrides. Based on the schema the operator provides values for the override variables. | | +| Step 3 (M) | Ops Personnel makes request to SMO to deploy new rApp(s) on the Non-RT RIC. | | +| Step 4 (M) | For the selected option get the DeploymentItems for the selected option. | | +| Step 5 (O) | The SMO decomposes the service request and identifies all rApps to be deployed and the order in which they should be deployed. | | +| Steps 6-16 | These steps are repeated for each rApp to be deployed as part of the deployment Option. | | +| Step 6 (M) | The SMO determines which O-Cloud and Non-RT RIC Instance to deploy the rApp to. This can be done using Policies which match operator input or other more complex homing policies, or can be explicitly identified by the Ops Personnel. | | +| Step 7 (M) | For each deployment of the rApp in the deployment option, the following steps 7 – 11 take place:
The deployment requires a CloudNativeDescriptor which is retrieved from the Run Time Library for the current DeploymentItem being deployed. | | +| Step 8 (M) | SMO directs the O-Cloud DMS using O2 to create the Deployment | | +| Step 9 (M) | DMS allocates the resources according to the NF Deployment request. During the NF Deployment instantiation, day-0 configuration can take place. | | +| Step 10 (M) | DMS returns notification to SMO over O2 indicating that the deployment has been created and the Deployment ID | | +| Step 11 (M) | SMO updates its rApp inventory with the received Deployment ID | | +| Step 12 (M) | rApp registers with the Non-RT RIC via the R1 interface | | +| Step 13 (O) | Optional implementation of the Non-RT RIC to detect when rApp is requesting data that is anchored in the SMO and initiate a request for that data. | | +| Step 14 (O) | Optional implementation of the Network Function Manager to evaluate current data jobs and determine if data is already available or a job needs to be created or updated. | | +| Step 15 (O) | Optional implementation of the Network Function Manager to create or update jobs dynamically. | | + +| Use Case Stage | Evolution / Specification | <>
Related use | +|-----------------|-----------------------------------------------------------------------------------------------------------------|-------------------------| +| Step 16 (M) | If a job is to be updated or created then the O1 interface is used. | | +| Step 17 (M) | The SMO informs the Ops Personnel of the overall success or failure of the request. | | +| Ends when | rApp(s) have been instantiated as SMO deployment(s) on the O-Cloud and configured by the SMO via the Non-RT RIC | | +| Exceptions | rApp Deploy fails – DMS notifies SMO and SMO informs Ops Personnel | | +| Post Conditions | rApp is instantiated and incorporated under Non-RT RIC management. | | +| Traceability | TBD | | + +![Sequence diagram for rApp Deployment process](63e256b2796736d556073f0f6b4b07db_img.jpg) + +``` + +sequenceDiagram + participant Ops as Operations Personnel + participant SMO as Service Management & Orchestration Framework + participant OCP as O-Cloud Platform + participant ORAN as O-RAN + + SMO-->>Ops: 1 Get Deployment Options + Note over SMO: Determine Runtime Variables for each **DeploymentItem. This includes the initial rApp config. Post deployment the xApp is configured through the Non-RT RIC via RT. + Ops-->>SMO: 2 + SMO-->>Ops: 3 Deployment Request (selectedOption) + SMO-->>SMO: 4 Get DeploymentItem for Selected Option + SMO-->>SMO: 5 Decompose and determine sequence + Note over SMO: The SMO determines the correct sequence for deploying the rApps + loop [for each rApp to be deployed] + SMO-->>SMO: 6 Determine homing + Note over SMO: The SMO determines on which Non-RT RIC/O-Cloud to deploy this/these xApp(s). This can be explicitly identified by the Operations Personnel or via homing policies + rAppDeploy: rApp Deploy + loop [Foreach DeploymentItem] + SMO-->>SMO: 7 Get CloudNativeDescriptor for DeploymentItem + SMO-->>OCP: 8 *O2* Create Workload (DeploymentItem, RuntimeVariables) + OCP-->>SMO: 9 create + SMO-->>OCP: 10 notify deployment instantiation is completed (DeploymentID) + SMO-->>SMO: 11 Once complete, SMO updates its rApp inventory record with the Deployment ID from the O-Cloud + SMO-->>ORAN: 12 *R1* Register (RTE Descriptor) + opt [If rApp is requesting O1 or SMO data then] + SMO-->>SMO: 13 Request SMO data + SMO-->>SMO: 14 Evaluate Request + end + opt [If new NnS data is required then] + SMO-->>ORAN: 15 translate requirements to PM request (new/update) + ORAN-->>SMO: 16 *O1* PM Job Changes + end + end + end + SMO-->>Ops: 17 rApp Deployment status (Success) + +``` + +The diagram illustrates the rApp Deployment process across several components: Operations Personnel, Service Management & Orchestration Framework (SMO), O-Cloud Platform, and O-RAN. The process begins with the Operations Personnel requesting deployment options, followed by the SMO determining runtime variables and decomposing the request into a sequence of rApps. The SMO then determines the homing for each rApp and proceeds to deploy them. The deployment involves creating workloads on the O-Cloud Platform, registering the rApps with the O-RAN, and updating the SMO's inventory. The process concludes with the SMO notifying the Operations Personnel of the successful deployment. + +Sequence diagram for rApp Deployment process + +# Annex D (normative): Shared O-RU + +Editor's note: The content of this Annex has been copied from an earlier specification without significant changes. This content is available for review and subsequent inclusion into the main body of the specification, taking into account both the technical validity of the content and alignment with the rest of the specification. When relevant content is moved, it should at the same time be removed from the Annex, and empty clauses voided. + +## D.1 Introduction + +A Shared O-RU deployment allows one or more operators to connect their O-DUs to an O-RU and share its resources. + +An O-DU should simultaneously support connections to non-Shared O-RUs, Multi O-DU O-RUs and/or Multi-Operator O-RUs, dependent on which Shared O-RU features the O-DU supports. + +Refer to OFH M-Plane [1] for more details of Shared O-RU. + +## D.2 Single Operator Shared O-RU + +### D.2.1 O-DU(s) roles + +In Single Operator Shared O-RU deployment, O-DUs do not have specific access privilege roles as in Multi-Operator Shared O-RU. O-DUs use the same access control groups as in non-Shared O-RU. + +In hierarchical deployment, O-DUs all use the same access control group “sudo” toward the Multi O-DU O-RU. One O-DU acts as primary O-DU responsible for configuring general OAM related configuration, supervision per O-DU, NETCONF call home and managing general OAM functions. + +Refer to clause 4.2.1 and OFH M-Plane [1], clause 6.5 for further details. + +### D.2.2 Configuring O-RU + +#### D.2.2.1 Configuring O-RU general OAM related configuration + +In hierarchical deployment, it is recommended that SMO configures general OAM related configuration for each Multi O-DU O-RU using O1 toward only one sharing O-DU (primary). That O-DU then consequently uses the configuration data to configure the Multi O-DU O-RU over its Open Fronthaul M-Plane interface. If SMO configures the same Multi O-DU O-RU through more than one sharing O-DU, it is recommended that SMO validates outside of the O-DUs that the configuration is aligned in all the sharing O-DUs to avoid configuration discrepancy. How validation is done is out of the scope of the present document. + +NOTE: O-RU does not check which O-DU(s) is configuring it, nor does it validate if, e.g., same parameter is configured to different allowed values by O-DUs. + +In hybrid deployment, it is recommended that SMO directly configures all general OAM related configuration for each Multi O-DU O-RU over its Open Fronthaul M-Plane interface. + +Refer to clause 4.2.1 for further details. + +#### D.2.2.2 Managing O-RU general OAM related functions + +In hierarchical deployment, it is recommended that SMO manages Multi O-DU O-RU general OAM functions using O1 toward only one sharing O-DU (primary), for example: software management, file Management, synchronization aspects, antenna line devices, operational aspects of external IO, O-RU connectors, beamforming configuration update, user account provisioning. If SMO manages general OAM functions for the same Multi O-DU O-RU through more than one sharing O-DU, it is recommended that SMO co-ordinates the O-DUs that the management is aligned in all of the sharing O-DUs to avoid discrepancy. How validation is done is out of the scope of the present document. + +In hybrid deployment, it is recommended that SMO directly manages all Multi O-DU O-RU general OAM functions for each Multi O-DU O-RU over its Open Fronthaul M-Plane interface. + +O-DUs may manage other O-RU functions independently, e.g., NETCONF connection establishment, performance management, fault management, static configuration for PRACH and SRS. + +Refer to OFH M-Plane [1], clauses 8, 12, 13, 14.4, 14.5, 14.6, 15.4 for further details. + +#### D.2.2.3 Configuring carrier configuration + +SMO shall configure only the cells that the O-DU serves and their corresponding carriers over O1 towards that O-DU. The O-DU shall then consequently configure the corresponding tx/rx-array-carriers on the Multi O-DU O-RUs over their Open Fronthaul M-Plane interfaces. + +#### D.2.2.4 Carrier state management + +An O-DU shall only activate or deactivate the tx/rx-array-carriers on the Shared O-RU that belongs to the cells that the O-DU serves. + +When an O-DU receive a notification from a Shared O-RU indicating tx/rx-array-carrier state change, the O-DU shall treat the notification in the same way as for a non-shared O-RU, i.e., O-DU shall ignore the notifications that do not relate to the O-DU cell's NRSectorCarriers. + +### D.2.3 Supervision Monitoring per O-DU + +In hierarchical deployment, SMO may configure SecondaryODuInfo including attribute *supervisionPerODu* over O1 on the primary O-DU. The primary O-DU shall then consequently configure Shared Resource Operator O-DU supervision on each Shared O-RU. + +In hybrid deployment, SMO instead may configure Shared Resource Operator O-DU supervision directly on each Shared O-RU over its Open Fronthaul M-Plane interface. + +Refer to OFH M-Plane [1], clauses 6.7, 19.3.4 for further details. + +### D.2.4 NETCONF call home + +In hierarchical deployment, SMO may configure the SecondaryODuInfo including attribute *callHomeClientInfo* over O1 only on the primary O-DU. If *callHomeClientInfo* has been configured, the primary O-DU shall then consequently configure call home addresses on each Shared O-RU. + +In hybrid deployment, SMO instead may configure call home addresses directly on each Shared O-RU over its Open Fronthaul M-Plane interface. + +## D.3 Multi Operator Shared O-RU + +### D.3.1 O-DU(s) roles + +O-DU possible roles towards a Multi Operator Shared O-RU are defined in OFH M-Plane [1]. O-DU role towards all connected Multi Operator Shared O-RUs is configured over O1 by setting *oDuRoleOfSharedORu* to one of the values: "HOST\_AND\_SRO", "HOST" or "SRO". + +When O-DU role is set to "HOST\_AND\_SRO", the O-DU simultaneously perform the Shared O-RU Host role and the Shared Resource Operator roles towards all connected Multi Operator Shared O-RUs. + +When O-DU role is set to "HOST", the O-DU only performs the Shared O-RU Host role, equaling Neutral Host. That O-DU configures and manages all connected Multi Operator Shared O-RUs but does not have carriers in those O-RUs. + +For each Multi Operator Shared O-RU, at most only one connected O-DU should perform the Shared O-RU Host role. If no connected O-DU performs the Shared O-RU Host role, it is assumed that an SMO performs that role, acting as + +Neutral Host. However, the scenario in which the Neutral Host is provided by SMO is not considered in this version of the document. + +In a hierarchical deployment containing Multi Operator Shared O-RUs, the O-DU performing the Shared O-RU Host role uses the access control group “sudo” toward all connected Multi Operator Shared O-RUs. The O-DUs performing only the Shared Resource Operator role (i.e., not together with the Shared O-RU Host role) use the access control group “carrier” towards all connected Multi Operator Shared O-RUs. + +In a hybrid deployment containing Multi Operator Shared O-RUs, if an O-DU performs the Shared O-RU Host role, it uses the access control group “hybrid-odu” toward the Multi O-DU O-RU. The O-DUs performing only the Shared Resource Operator role (i.e., not together with the Shared O-RU Host role) use the access control group “carrier” towards all connected Multi Operator Shared O-RUs. + +Following sub-clauses define what shall be configured over O1 to O-DU to realize O-DU functions defined in OFH M-Plane [1]. + +### D.3.2 Configuring O-RU general OAM related configuration + +In hierarchical deployment, it is recommended that SMO configures O-RU general OAM related configuration over O1 toward only the single Shared O-RU Host O-DU. The Shared O-RU Host O-DU shall then consequently configure general OAM related configuration on the Multi Operator O-RUs over their Open Fronthaul M-Plane interfaces. + +In hybrid deployment, it is recommended that SMO directly configures general OAM related configuration for each Multi O-DU O-RU over its Open Fronthaul M-Plane interface. + +### D.3.3 Managing O-RU general OAM related functions + +In hierarchical deployment, it is recommended that SMO manages O-RU general OAM related functions over O1 toward only the single shared O-RU Host O-DU. The Shared O-RU Host O-DU shall then consequently manage general OAM related functions on the Multi Operator O-RUs over their Open Fronthaul M-Plane interfaces. + +In hybrid deployment, it is recommended that SMO directly manages Multi O-DU O-RU general OAM functions for each Multi O-DU O-RU over its Open Fronthaul M-Plane interface. + +### D.3.4 NETCONF server user account provisioning for shared resource operators + +In hierarchical deployment, SMO shall configure the SecondaryODuInfo over O1 only on the Shared O-RU Host O-DU. The Shared O-RU Host O-DU shall then consequently configure Shared Resource Operator user accounts with “carrier” access privilege and *sro-id=sharedResourceOperatorId* on the connected Multi Operator O-RUs over their Open Fronthaul M-Plane interfaces. + +NOTE: Value of each *sharedResourceOperatorId* shall be unique and associated with a particular Shared Resource Operator only. + +In hybrid deployment, SMO instead configures Shared Resource Operator user accounts with “carrier” access privilege and *sro-id=sharedResourceOperatorId* directly on each Multi Operator O-RU over its Open Fronthaul M-Plane interface. + +Refer to OFH M-Plane [1], clause 19.3.1 for further details. + +### D.3.5 NETCONF call home + +In hierarchical deployment, SMO may configure the SecondaryODuInfo including attribute *callHomeClientInfo* over O1 only on the Shared O-RU Host O-DU. If *callHomeClientInfo* has been configured, the Shared O-RU Host O-DU shall then consequently configure call home addresses on each Shared O-RU. + +In hybrid deployment, SMO instead may configure call home addresses directly on each Shared O-RU using its Open Fronthaul M-Plane interface. + +Refer to OFH M-Plane [1], clause 19.3.2 for further details. + +### D.3.6 Enhanced sro-id based NETCONF access control + +SMO shall configure the attribute *sharedResourceOperatorId* over O1 with a unique value on each Shared Resource Operator O-DU. The Shared Resource Operator O-DU shall then consequently use the value of *sharedResourceOperatorId* for the user account of the NETCONF client with sro-id configured on the Multi Operator Shared O-RUs. + +Refer to OFH M-Plane [1], clause 19.3.3 for further details. + +### D.3.7 Supervision Monitoring per O-DU + +In hierarchical deployment, SMO may configure SecondaryODuInfo including attribute *supervisionPerODu* over O1 on the Shared O-RU Host. The Shared O-RU Host shall then consequently configure Shared Resource Operator O-DU supervision on each Shared O-RU. + +In hybrid deployment, SMO instead may configure Shared Resource Operator O-DU supervision directly on each Shared O-RU using its Open Fronthaul M-Plane interface. + +Refer to OFH M-Plane [1], clauses 6.7, 19.3.4 for further details. + +### D.3.8 Processing element configuration + +Shared O-RU Host O-DU shall use the value of each Shared Resource Operator O-DUs *sharedResourceOperatorId* attribute to configure a particular O-RU's ru-element list entry as being uniquely associated with a particular Shared Resource Operator. Shared O-RU Host O-DU gets *sharedResourceOperatorId* as defined in D.3.6. + +Refer to OFH M-Plane [1], clause 19.4.2. + +### D.3.9 Carrier Partitioning and Configuration in Shared O-RU + +Only Shared O-RU Host O-DU has access privileges over Open Fronthaul M-Plane to create tx/rx-array-carrier configuration in the Shared O-RU. + +NOTE 1: How Shared Resource Operators agree configuration partitioning is outside the scope of the present document. It is assumed that operators mutually agree partitioning. + +NOTE 2: How Shared Resource Operators configurations are validated is outside the scope of the present document. It is assumed that operators mutually validate as part of configuration partitioning. + +NOTE 3: How Shared Resource Operators agree eAxC-IDs partitioning is out of the scope of the present document. It is assumed that operators mutually agree partitioning. + +Refer to clause 4.2.1 and OFH M-Plane [1], clauses 19.6.1, 19.11. + +### D.3.10 Notification of configuration updates + +A Shared Resource Operator O-DU may configure subscriptions to receive notifications of modifications to a connected shared O-RU's datastore, according to the defined NETCONF access control privileges for the NETCONF client of that Shared Resource Operator. + +Refer to clause 4.2.1 and OFH M-Plane [1], clause 19.6.2 for further details. + +### D.3.11 Shared O-RU Reset Co-ordination + +Co-ordination of Shared O-RU reset is outside the scope of the current specification. + +NOTE 1: It is assumed that operator mutually agree time when Shared O-RU Host O-DU reset Shared O-RU. + +NOTE 2: It is assumed that SMO(s) disable cell(s) in a controlled manner before Shared O-RU reset. + +Refer to OFH M-Plane [1], clause 19.10.1 for further details. + +### D.3.12 Locked administrative state + +Co-ordination of Shared O-RU administrative state change to locked is outside the scope of the current specification. + +NOTE 1: It is assumed that operators mutually agree time when Shared O-RU Host O-DU change Shared O-RU administrative state to locked. + +NOTE 2: It is assumed that SMO(s) disable cell(s) in a controlled manner before Shared O-RU state is changed to locked. + +Refer to OFH M-Plane [1], clause 19.10.2 for further details. + +### D.3.13 Antenna calibration + +Co-ordination of Shared O-RU antenna calibration timing is outside the scope of the current specification. + +NOTE: It is assumed that operators mutually agree timing for Shared O-RU antenna calibrations. + +Refer to OFH M-Plane [1], clause 19.10.3 for further details. + +### D.3.14 Shared O-RU with antenna line devices + +The Shared O-RU Host O-DU is responsible for configuring and controlling antenna line devices. + +NOTE: It is assumed that operators mutually share antenna line devices configuration and co-ordinate antenna line operations, e.g., remote electrical tilt. + +Refer to OFH M-Plane [1], clauses 14.4, 19.11.6. + +### D.3.15 Shared O-RU operation in combination with shared cell + +The Shared O-RU Host O-DU is responsible for configuring shared cell copy and combine parameters on behalf of each Shared Resource Operator O-DU. + +NOTE: How Shared Resource Operators agree Shared Cell configuration of copy and combine is outside the scope of the present document. It is assumed that operators mutually agree partitioning. + +Refer to OFH M-Plane [1], clauses 17, 19.14 for further details. + +## D.4 Content of Open Fronthaul M-Plane ODU ID + +O-DU uses the value of the attribute *oDulIdForSharedORu* as the Open Fronthaul M-Plane odu-id, which is a free text string and can be set to, e.g., concatenated gNBId and gNBDUId. + +## D.5 Content of Open Fronthaul M-Plane SRO ID + +O-DU uses the value of the attribute *sharedResourceOperatorId* as the Open Fronthaul M-Plane sro-id, which is a free text string and can be set to, e.g., PLMN ID. + +# Annex E (informative): Network Energy Saving + +Editor's note: The content of this Annex has been copied from an earlier specification without significant changes. This content is available for review and subsequent inclusion into the main body of the specification, taking into account both the technical validity of the content and alignment with the rest of the specification. When relevant content is moved, it should at the same time be removed from the Annex, and empty clauses voided. + +Editor's note: The content of this clause needs to be reviewed and potentially revised to ensure that the content is relevant to OAM. + +## E.1 Introduction + +This section describes the requirements and scope of the energy saving techniques, as described in NESUC [i.18], relevant to O1 interface and its associated information. The following techniques are employed to attain the network energy saving. + +## E.2 Cell and carrier deactivation / activation + +### E.2.1 Flow description + +1. The O-DU using Open Fronthaul M-Plane interface collects capabilities related to support for Network Energy Saving from the O-RU. The parameters that are exposed are out of scope of this specification. +2. O-DU using O1 interface exposes to MnS Consumer its capabilities along with O-RU capabilities reported in Step 1. +3. Via O1 interface the O-DU receives from MnS Consumer configuration needed to enable services. +4. O-DU internally applies received configuration (assumption: the configuration is valid – otherwise scenario stops with O-DU rejecting received configuration). +5. O-DU applies configuration to O-RU(s) using Open Fronthaul M-Plane interface where applicable, which is out of scope of this document. +6. O-DU exposes available traffic and/or load performance and energy consumption measurements data as per its current configuration to MnS Consumer via O1 interface. +7. MnS Consumer analyses above collected data. +8. Based on the analysis done in Step 7, MnS Consumer optionally prepares reconfiguration for the O-CU. The way how MnS Consumer controls O-CU is out of scope of this document. +9. O-DU receives list of cells to be deactivated / activated (it could also be single cell) over F1 interface, which is out of scope of this document. +10. As an alternative to Step 8, MnS Consumer optionally creates Energy Saving Policies for O-CU. The way how MnS Consumer controls O-CU is out of scope of this document. +11. O-CU periodically checks the conditions specified in the policy are fulfilled. The way how O-CU checks the conditions stated in the policy is out of scope of this document. +12. If policy conditions are fulfilled, O-DU optionally receives the list of cells to be activated/deactivated over F1 interface, which is out of scope of this document. +13. O-DU translates between cells and associated carriers that serve for such cells. + +14. O-DU performs deactivation / activation of carriers in O-RU through Open Fronthaul M-Plane interface, where those carriers determined in Step 9 and Step 13. This is out of scope of this document. +15. The flow loops to Step 6 as shown in Figure E.2.1-1. + +![Sequence diagram for Network Energy Saving - Cell and carrier deactivation / activation use case. The diagram shows interactions between MnS Consumer, O-CU, O-DU, and O-RU. It includes steps for exposing capabilities, receiving configuration, applying configuration, and a loop for periodic checks and deactivation/activation of cells and carriers.](210304c3521acf4627854e72f2843931_img.jpg) + +``` + +sequenceDiagram + participant MnS as MnS Consumer + participant OCU as O-CU + participant ODU as O-DU + participant ORU as O-RU + + Note over ORU: 1 O-RU exposes Energy Saving related capabilities + Note over ODU: 2 «O1» O-DU exposes its Energy Saving related capabilities along with O-RU(s) capabilities + Note over MnS: 3 «O1» O-DU receives configuration needed to enable services + Note over ODU: 4 O-DU uses received configuration + Note over ORU: 5 Apply configuration in O-RU + + loop + Note over ODU: «O1» O-DU exposes available traffic, load, performance and energy consumption measurements as per its configuration + Note over MnS: 6 + Note over ODU: 7 Collected data evaluation + + opt + alt + Note over MnS: 8 «O1» Cell(s) deactivation/activation + Note over ODU: 9 O-DU receives the list of cells to be deactivated/activated + and + Note over MnS: 10 «O1» New ESP with rules for Cell deactivation/activation use case + Note over ODU: 11 Periodically checks if conditions in specific policy are fulfilled + opt [Conditions fulfilled] + Note over ODU: 12 O-DU receives the list of cells to be deactivated/activated + end + end + end + + Note over ODU: O-DU process the above request and translates between cells and associated carriers + Note over ORU: 13 + Note over ORU: 14 Carrier deactivation/activation + end + +``` + +The diagram illustrates the Network Energy Saving - Cell and carrier deactivation / activation use case. It involves four main entities: MnS Consumer, O-CU, O-DU, and O-RU. The process begins with the O-RU exposing its Energy Saving related capabilities (Step 1). The O-DU then exposes its own capabilities along with the O-RU's (Step 2). The MnS Consumer sends configuration needed to enable services to the O-DU (Step 3). The O-DU uses this configuration (Step 4), and it is applied in the O-RU (Step 5). A loop structure follows, where the O-DU exposes available traffic, load, performance, and energy consumption measurements (Step 6). The MnS Consumer receives this data (Step 7). An optional block (opt) contains an alternative (alt) scenario. In the alt block, the MnS Consumer sends a request for cell(s) deactivation/activation (Step 8), and the O-DU receives a list of cells to be deactivated/activated (Step 9). Alternatively, the MnS Consumer sends a new ESP with rules for cell deactivation/activation use case (Step 10), and the O-DU periodically checks if conditions in a specific policy are fulfilled (Step 11). If conditions are fulfilled (opt block), the O-DU receives a list of cells to be deactivated/activated (Step 12). The O-DU then processes the request and translates between cells and associated carriers (Step 13). Finally, the O-RU performs carrier deactivation/activation (Step 14). The flow loops back to Step 6. + +Sequence diagram for Network Energy Saving - Cell and carrier deactivation / activation use case. The diagram shows interactions between MnS Consumer, O-CU, O-DU, and O-RU. It includes steps for exposing capabilities, receiving configuration, applying configuration, and a loop for periodic checks and deactivation/activation of cells and carriers. + +Figure E.2.1-1: Network Energy Saving - Cell and carrier deactivation / activation use case + +This method shall be used to achieve energy saving by deactivating a cell(s) and its associated carriers. + +From O-DU perspective it does not matter if cell deactivation / activation request is received because of direct command sent to O-CU by MnS Consumer or is result of processing of the policies in the list (conditionals formed in any Energy Saving Policy in the list for cell deactivation or activation are determined as fulfilled by O-CU). In case of policy processing assumed is, that O-CU knows at least one Energy Saving Policy (ESP) that may lead to cell disablement / enablement. + +At O-DU level the scenario is always containing list of cells to be deactivated or activated. Content is processed by O-DU. Carriers related to cells requested are determined. Knowing translation between cells and carriers, the O-DU requests O-RU to deactivate / activate determined [tr]x-array-carriers accordingly. + +## E.3 Void + +## E.4 Void + +# Annex F (informative): Policy Example + +A policy can be defined for certain optimization use cases, for instance, Network Energy Saving. The attributes defined for a certain policy may contain a statement, target, resources, constraints, and sometimes trigger as well. The attributes can be activated or applied within a particular policy scope, depending on the condition and/or trigger. + +Examples of attributes are defined in Table F-1 below. + +**Table F-1: Policy attribute examples** + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| Policy Scope | Cell A | +| Policy Statement | Achieve energy optimization in Cell A | +| Policy Objective | antenna mask = 1
targetEC = X kWh
QoSImpact = No impact/Min/Medium/Max
ValidDuration = X minutes/hours | +| Condition/Trigger |
  • • If traffic is below Y % or
  • • Y % reduction in traffic and Energy consumption is > K kWh.
| + +# --- Annex ZZZ: Void + +# Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.07.18 | 13.00 | Final version for July 2024 train | +| 2024.08.21 | 13.00.01 | Incorporates this CR:
  • ATT-2024.04.16-WG10-CR-0010-MDC UC Error Corrections-v03
| +| 2024.11.22 | 13.00.02 | Incorporates whitespace corrections and these CRs:
  • NOK-2024.09.02-WG10-CR-0092-ALD control addition to OAM Arch spec v03
  • RMI.AO-2024.08.20-WG10-CR-0010-OAMArch-Policy Management Usecase v13
| +| 2024.11.25 | 13.00.03 | Incorporates corrections to earlier CR implementations, punctuation corrections, further whitespace corrections, and these CRs:
  • ERI-2024.09.30-WG10-CR-0116-OAMArch_AbbrevCleanup-v01
  • ERI-2024.09.30-WG10-CR-0117-OAMArch_3GPP_Rel_18-v01
  • ERI-2024.09.30-WG10-CR-0118-OAMArch_PlantUML-v01
  • ERI-2024.10.01-WG10-CR-0119-OAMArch_OpenFH-v01
  • ERI-2024.10.02-WG10-CR-0120-OAMArch_TRX_Ctrl_cleanup-v01
  • ERI-2024.10.02-WG10-CR-0121-OAMArch_ASM_cleanup-v01
  • ERI-2024.10.02-WG10-CR-0122-OAMArch_UC_ITU_T_M3020-v01
| +| 2024.11.27 | 13.00.04 | Incorporates corrections to earlier CR implementations | +| 2024.11.27 | 14.00 | Final version for November 2024 train | \ No newline at end of file diff --git a/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2fd5eaeff22262dc085e14adfdb0ad2472ac9dc2 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd2727019ae96e80efda4964e1a871737c2c73277a978726969f55d0e5275c2f +size 4536 diff --git a/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3a71b98fcfc274b0603208cc5e23601d7fc924a --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84a0e505aa8e8fcec39c03736b466858a7c1ef91abe309cdd2974ee18257e23b +size 4531 diff --git a/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82827af191c934857f3a5a97842fa19fb4aa5978 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54f690c723a011f67b244eeda5cca1f67e7a7784e122d72a637cea1ca968c8f4 +size 4531 diff --git a/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/b3e68315f0e6ea8124411ead9c63301c_img.jpg b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/b3e68315f0e6ea8124411ead9c63301c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1e35ba18a62f656f7f1a6b24fea7c8be2674a978 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/b3e68315f0e6ea8124411ead9c63301c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:42d4e88add7c629c02ad0cab786940302fb52987a0763bedc841b703b8c610d5 +size 27681 diff --git a/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/ce0e8d148c406f38bca7593d818d277c_img.jpg b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/ce0e8d148c406f38bca7593d818d277c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..638463377777318113b683309b73101b300e3e87 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/ce0e8d148c406f38bca7593d818d277c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a1bec52591ac42774098f881d2332c88609df758846d0a51a1e390c45b1f45ee +size 4521 diff --git a/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f9786619d9266ddf6962b7631fad8834bd583a3 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:17a48c732b82959a70a4744afdf56099b05c77a70dfcfaa935549c6ab678bec2 +size 4509 diff --git a/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/d609d9c9c30cc42371bd69a498d85237_img.jpg b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/d609d9c9c30cc42371bd69a498d85237_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4b227355bf9cf57b89301e601b6d7732aba4d0d1 --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/d609d9c9c30cc42371bd69a498d85237_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ca1f79f98c52ef3ffa662afbc153c0ae0a73a4c3b465786d9706c429d34db951 +size 4575 diff --git a/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/raw.md b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..4d396f94957a8f2c7f7f51b37a8dd06e679cbf1e --- /dev/null +++ b/marked/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00/raw.md @@ -0,0 +1,413 @@ + + +# --- **O-RAN Work Group 10 (OAM for O-RAN)****Onboarding SMOS General Aspects and Principles** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|--------------------------------------------------------------------|----| +| List of figures ..... | 4 | +| List of tables ..... | 4 | +| Foreword..... | 5 | +| Modal verbs terminology ..... | 5 | +| 1 Scope ..... | 6 | +| 2 References ..... | 6 | +| 2.1 Normative references ..... | 6 | +| 2.2 Informative references ..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 7 | +| 3.1 Terms ..... | 7 | +| 3.2 Symbols..... | 7 | +| 3.3 Abbreviations ..... | 7 | +| 4. Application Lifecycle Management (LCM)..... | 7 | +| 4.1 Onboarding in the Software Lifecycle ..... | 7 | +| 4.2 Onboarding Activity ..... | 8 | +| 5 General Aspects of the Onboarding SMOS ..... | 8 | +| 5.1 ETSI Alignment ..... | 8 | +| 5.1.1 ETSI GS NFV SOL004 [2] Alignment..... | 8 | +| 5.2 Onboarding as a distributed SMOS ..... | 8 | +| 5.2.1 Design Patterns for Onboarding..... | 8 | +| 5.2.2 Replicated Load-Balanced Services..... | 9 | +| 5.2.3 Saga ..... | 9 | +| 5.3 Messaging ..... | 9 | +| 5.3.1 Procedure Requests ..... | 9 | +| 5.3.2 Procedure Responses..... | 9 | +| 5.3.3 Published Notifications ..... | 9 | +| 5.4 Reference vs Copy ..... | 10 | +| 5.5 General Aspect: Idempotence ..... | 10 | +| 5.6 Role Based Access..... | 10 | +| 6 Principles of the Onboarding SMOS..... | 11 | +| 6.1 Contained Functionality of the Onboarding SMOS..... | 11 | +| 6.1.1 Package Security ..... | 11 | +| 6.1.2 Package Delivery Format ..... | 11 | +| 7 Onboarding Use Cases ..... | 11 | +| 7.1 Use Case Overview..... | 11 | +| 7.2 Onboard..... | 12 | +| 7.3 Deprecate ..... | 12 | +| 7.4 Forced Delete ..... | 12 | +| 7.5 Application List Query ..... | 12 | +| 7.6 Application Manifest Query ..... | 13 | +| 7.7 Application Artifact Query ..... | 13 | +| 7.8 Application Delete Cancellation ..... | 13 | +| 8 Onboarding Service Requirements ..... | 13 | +| 9 Onboarding Service Information Model ..... | 13 | +| Annex A (informative): ..... | 14 | +| Annex (informative): Change history/Change request (history) ..... | 15 | + + + +# --- List of figures + +| | | +|---------------------------------------------------------------------|---| +| Figure 4.2-1: Activities of the Application Onboarding Process..... | 7 | +|---------------------------------------------------------------------|---| + +# --- List of tables + +No table of figures entries found. + +# --- Foreword + +This Technical Specification (TS) has been produced by WG10 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the general aspects and principles of the Onboarding SMOS as described in the SMO Decomposition TR [i.3], clause 5.11. The specification identifies where the service fits into the Application Lifecycle as described in the OAM Architecture [i.5], clause 6. Beyond the general aspects and principles, this document provides the use cases from the user perspective and specifies the service procedures, requirements, and information model for the service. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN.WG11-O-RAN-Security-Requirements-Specification: “O-RAN Security Requirements” +- [2] ETSI GS NFV-SOL 004 v5.1.1, " Network Functions Virtualisation (NFV) Release 5; Protocols and Data Models; VNF Package and PNFD Archive specification", July 2024 + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. +- [i.2] O-RAN WG1-O-RAN Architecture Description: “O-RAN Architecture Description” +- [i.3] O-RAN WG1-Decoupled-SMO-Architecture: “Decoupled SMO Architecture” +- [i.4] O-RAN.WG6.ORB, “Cloudification and Orchestration Use Cases for O-RAN Virtualized RAN” +- [i.5] O-RAN.WG10.OAM-Architecture: "OAM Architecture" + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in 3GPP TR 21.905 [i.1] apply. + +**NOTE:** A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [i.1]. + +**SMO:** A Service Management and Orchestration framework as described in the O-RAN WG1.OAD [i.2]. + +**Application:** The software aspect of a vendor product for a Network Element [i.3], an xApp or rApp which is sold/delivered to an operator. + +**Application Artifact:** A file contained within an archive such as the Application Package. + +**Application Package:** The set of information provided by a Solution Provider to a Service Provider representing all or a component of an Application. + +**Onboarding:** The process of validating and ingesting an Application Package to make it available to other services within the SMO. + +**Service Provider:** The RAN service provider often referred to as the operator. + +**Solution Provider:** Application development entity often referred to as a vendor. + +**xApp:** An application designed to run on the near-RT RIC as described in the O-RAN Architecture Description [i.2]. + +## 3.2 Symbols + +For the purposes of the present document, the symbols given in 3GPP TR 21.905 [i.1] apply. + +**NOTE:** A symbol defined in the present document takes precedence over the definition of the same symbol, if any, in 3GPP TR 21.905 [i.1]. + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [i.1] and the following apply. + +**NOTE:** An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [i.1]. + +| | | +|-------|-------------------------------------------------------------| +| FCAPS | Fault, Configuration, Accounting, Performance, and Security | +| OAM | Operations, Administration, and Maintenance | +| RLBS | Replicated Load-Balanced Services | + +# --- 4. Application Lifecycle Management (LCM) + +## 4.1 Onboarding in the Software Lifecycle + +The Application Software Lifecycle is described in the OAM Architecture [i.5], clause 6. The onboarding phase identifies the "Onboarding" activity. This specification will detail the process that an Application Package from a Solution Provider is delivered to the Service Provider through the "Marketplace" external Meet Me Point. + +Applications should be onboarded in a common manner, regardless of how they are deployed. The Application Package contents are dependent on the type of application being onboarded. The required artifacts and their format are defined in a separate specification, currently under development. The conventions used to convey the details of Onboarding activity are described in the OAM Architecture [i.5], figure 6.1-4. + +## 4.2 Onboarding Activity + +The fine-grained activities of the Onboarding are shown below in figure 4.2-1. Activities of the Onboarding Service which impact the content of the Application Package are highlighted in bold. All the functions of this activity are specific to the Onboarding Service. + +![Figure 4.2-1: Activities of the Application Onboarding Process. The diagram shows a sequence of activities: 'onboard' from Marketplace to a green circle, 'verify' from the green circle to another green circle, 'unpack' from the second green circle to a third green circle, and 'delete' from the third green circle to a black circle. A 'Catalogue' cylinder is connected to the third green circle with a double-headed arrow. A 'query' arrow points from the Catalogue to a green circle. A 'feedback' arrow points from the second green circle back to the Marketplace. A curved arrow labeled '[invalid]' points from the second green circle back to the first green circle.](b3e68315f0e6ea8124411ead9c63301c_img.jpg) + +``` + +graph LR + Marketplace[Marketplace] -- onboard --> C1(( )) + C1 -- verify --> C2(( )) + C2 -- unpack --> C3(( )) + C3 -- delete --> End(( )) + C3 <--> Catalogue[(Catalogue)] + Catalogue -- query --> C4(( )) + C2 -- feedback --> Marketplace + C2 -- "[invalid]" --> C1 + +``` + +Figure 4.2-1: Activities of the Application Onboarding Process. The diagram shows a sequence of activities: 'onboard' from Marketplace to a green circle, 'verify' from the green circle to another green circle, 'unpack' from the second green circle to a third green circle, and 'delete' from the third green circle to a black circle. A 'Catalogue' cylinder is connected to the third green circle with a double-headed arrow. A 'query' arrow points from the Catalogue to a green circle. A 'feedback' arrow points from the second green circle back to the Marketplace. A curved arrow labeled '[invalid]' points from the second green circle back to the first green circle. + +**Figure 4.2-1: Activities of the Application Onboarding Process** + +An Application Package is onboarded from the exchange, and its content verified. If valid, its contents (the App) are unpacked and stored/referenced in a catalogue. If invalid, the Service Provider may provide AppPackage-level feedback to the Solution Provider via the Marketplace. The capabilities described in this clause are the focus of the Onboarding SMOS. + +# 5 General Aspects of the Onboarding SMOS + +## 5.1 ETSI Alignment + +### 5.1.1 ETSI GS NFV SOL004 [2] Alignment + +Per the O-RAN Security Requirements [1] the package will follow the security requirements of ETSI GS NFV SOL004 [2]. However, SOL004 goes beyond just the security requirements and identifies a strict package artifact set. This set is not comprehensive enough to accommodate some Application Package capabilities required by O-RAN. Therefore, for ETSI based packages, ETSI GS NFV SOL004 [2] will be followed as specified. However, it is expected that there will be some augmentation of ETSI GS NFV SOL004 [2] or alternative approaches will be specified to cover O-RAN specific scenarios. + +## 5.2 Onboarding as a distributed SMOS + +### 5.2.1 Design Patterns for Onboarding + +The SMO may deploy one or more Onboarding SMOS instances based on the scale of Onboarding requests. The service assumes all instances are capable of onboarding a package. The FileSystem-As-A-Service can reduce physical data replication across service instance locations. However, it is expected that the Database-As-A-Service provides one consistent view of all Applications onboarded. Race conditions between services can exist if the same onboarding request is received independently to two different Onboarding SMOS instances. In this case resolution of the race condition is defined by the service implementation. + +There are common design patterns for implementing a distributed service. A design pattern is a tried and tested implementation example which allows developers to follow a behavioral model that other developers have successfully implemented. + +Conditions such as whether the service consumer is centralized or decentralized are considered to determine which pattern to use. + +To provide greater flexibility and interoperability multiple patterns may be integrated. For the Onboarding SMOS where a user wants to onboard an Application Package, it is used from a centralized perspective, two common patterns exist one synchronous and one asynchronous that are adaptable to the Onboarding SMOS, the Replicated Load-Balanced Services (RLBS) and Saga patterns respectively. + +### 5.2.2 Replicated Load-Balanced Services + +RLBS is one of the simplest and most commonly used design patterns. All the service instances use a common/central load balancer. The first service instance would establish the load balancer and point to the virtual endpoint provided by the load balancer in the service registry. Each additional service instance would add itself to the back end of the load balancer. Simple service healthchecks can take service instances in and out of service providing robustness of the service when individual instances fail. + +### 5.2.3 Saga + +Saga provides an asynchronous pattern where instead of directly calling the API, a message is sent over an Event Bus. This eliminates the central controller and its single point of failure. It also self-regulates any irregularities that may be induced due to the load balancing algorithm. However, it may become hard to debug when errors occur due to the non-deterministic assignment of work to an instance. + +## 5.3 Messaging + +### 5.3.1 Procedure Requests + +In this messaging model the subscriber(s) is one of the Onboarding SMOS. There could be potentially many publishers, Onboarding Service Consumers. The Onboarding SMOS will create the data product within the DME for the data structure to create an onboarding service request. Since some procedures are privileged and if supported through a notification then a form of authentication will have to be employed to ensure the requestor has the authorization to execute the procedure, + +### 5.3.2 Procedure Responses + +In this messaging model the publisher(s) is the Onboarding SMOS. There could be potentially many subscribers, Onboarding Service Consumers. The Onboarding SMOS will create the data product within the DME for the responses to onboarding service requests. + +### 5.3.3 Published Notifications + +In this messaging model there is one publisher, the Onboarding SMOS. There could be potentially many subscribers, Onboarding Service Consumers. The Onboarding SMOS will create the data product within the DME for the event(s) which will notify service consumers of state changes to Application Packages, + +## 5.4 Reference vs Copy + +The Onboarding Service provides reference to objects which may require modification prior to deployment and some which should never be modified. Some artifacts may be small and others extremely large. The strategy for data reference vs data replication should be documented. + +Large extremely static objects should only be replicated as needed for resiliency. Software binaries whether as a software update package or as an executable image in a cloud environment shouldn't be replicated for any other reason. Preferably the O-Cloud would have access to such a repository and therefore only the image reference would be registered with the O-Cloud for which it will receive a deployment request. + +Other data may or may not require modification prior to being able to deploy the application. When data has to be modified it is done in the local copy maintained by the Onboarding Consumer. When no modification is required and the Onboarding Consumer needs to provide the artifact to another entity it is preferable that it provides a reference to the original artifact rather than a copy to it. This limits the number of copies that must be managed when an application version is no longer required and SMO storage space needs to be reclaimed. + +## 5.5 General Aspect: Idempotence + +The overall concept of idempotence is that repeated requests for the same thing will result in the same outcome. This has some limitations when applied to the public procedures of the Onboarding service which are discussed here. + +The Onboarding procedure can be called multiple times to recover from procedural failures. But once the notification that the package has been made available to other SMOS, who may now reference the package data, reloading the package is not possible. To reload after this point, delete, due to scheduled delete or forced delete, is required before the package can be re-onboarded. + +Deprecate can be called repeatedly. If the Application Package is already in a DEPRECATED state no change to the record or its scheduled deletion time will occur, but success will still be returned to the consumer. + +Forced Delete causes the entry to no longer exist. Therefore, if the object does not exist it assumes it was previously deleted and instead of indicating a not found error, it will return an indication of success. + +Repeated calls to Cancel Delete will not change the state which would have been moved to AVAILABLE or modify the already cleared scheduled deletion time attribute. However, success will still be returned. + +Query is by default idempotent since it provides only read access to the data and no change occurs. + +## 5.6 Role Based Access + +The Onboarding service supports two roles, an operator user and an administrator user. To ensure that only entitled users are allowed to execute the procedures exposed by the Onboarding SMOS, the required role for each procedure is to be specified. + +# --- 6 Principles of the Onboarding SMOS + +## 6.1 Contained Functionality of the Onboarding SMOS + +### 6.1.1 Package Security + +#### 6.1.1.1 Application Package Supply Chain Security + +The Onboarding SMOS provides the functionality to meet all the security requirements assigned by O-RAN Security Requirements [1], clause 5.3.2.1.1 to the Application Package. The Onboarding SMOS verifies that the package and/or contained artifacts were properly signed and the Solution Providers certificate is valid. + +#### 6.1.1.2 Application Package Content Security + +The Onboarding SMOS provides the functionality to meet all the security requirements assigned by the O-RAN Security Requirements [1], clause 5.3.2.1.2 The Onboarding SMOS verifies that the package contents have not been modified since the package was created. + +### 6.1.2 Package Delivery Format + +#### 6.1.2.1 Application Package Archive Compression + +The Application Package is expected to be transported in a compressed format. The Onboarding SMOS provides the functionality to know how the received archive is uncompressed so that downstream consumers of the package artifacts are able to directly access an uncompressed version of the artifact. + +#### 6.1.2.2 Application Package Archive Structure + +The Application Package will have a defined structure that allows the Onboarding SMOS to locate the different artifacts. When the Onboarding SMOS extracts the artifacts and stores them in catalogues the package structure is not maintained. Once unpacked, individual artifacts are identifiable without the support of the package structure. Thus, consumers of individual artifacts are in general unaware of the original package structure and are not affected by changes in it. + +# 7 Onboarding Use Cases + +## 7.1 Use Case Overview + +The use cases below are high level descriptions from the perspective of the Onboarding Service Consumer. The use case identifies several aspects of the service behaviour the following variable are used to express the use case. + +| Variable Text | Description | +|-------------------------|------------------------------------------------------------------------------| +| Consumer | Who is requesting an operation to be performed by the Onboarding Service | +| Feature Name | What feature or capability is being requested | +| Feature Behavior | What extending behaviors does the feature need to provide, can be left blank | +| Expected Outcome | What is the expected outcome of the feature | +| Enabled Need | Why does the consumer need the feature | + +The variables can be inserted into an epic like story: + +As the {Consumer} I need the Onboarding Service to provide the capability to {Feature Name} [with the ability to {Feature Behavior}] to {Expected Outcome} so that I can {Enabled Need}. + +## 7.2 Onboard + +| Variable | Value | +|-------------------------|------------------------------------------------------------| +| Consumer | Service Designer | +| Feature Name | Onboard an Application | +| Feature Behavior | Recover from previous failures | +| Expected Outcome | Provide package artifacts in a catalogue | +| Enabled Need | Certify and/or train the Application as part of a service. | + +## 7.3 Deprecate + +| Variable | Value | +|----------|-------| +|----------|-------| + +| | | +|-------------------------|--------------------------------------------------------------------------------------------| +| Consumer | Service Designer | +| Feature Name | Deprecate an Application | +| Feature Behavior | Identify its scheduled deletion date | +| Expected Outcome | Change the Application Package state is DEPRECATED and establish a scheduled deletion date | +| Enabled Need | Retire older application versions once they are no longer needed by operations | + +## 7.4 Forced Delete + +| Variable | Value | +|-------------------------|-----------------------------------------------------------------------| +| Consumer | Systems Administrator | +| Feature Name | Force the deletion of an Application | +| Feature Behavior | Without regard to referential integrity | +| Expected Outcome | Application and its artifacts are forcibly deleted from the catalogue | +| Enabled Need | Cleanup Applications in the catalogue | + +## 7.5 Application List Query + +| Variable | Value | +|-------------------------|-------------------------------------------------------------| +| Consumer | Service Designer | +| Feature Name | Query for a list of available Applications | +| Feature Behavior | To filter by Application type, name, vendor, and/or version | +| Expected Outcome | A list of qualifying Applications can be identified | +| Enabled Need | The selection of an Application to retrieve | + +## 7.6 Application Manifest Query + +| Variable | Value | +|-------------------------|-----------------------------------------------------------------------------------------------------------------| +| Consumer | Service Designer | +| Feature Name | Query Application Manifest | +| Feature Behavior | To filter to exclude or include a list of artifacts | +| Expected Outcome | Application descriptive data and/or a list of qualifying artifacts each identified as a link to a readable file | +| Enabled Need | To get package data not included in an artifact | + +## 7.7 Application Artifact Query + +| Variable | Value | +|-------------------------|----------------------------------------------------------------------------------| +| Consumer | Service Designer | +| Feature Name | Query Application Artifacts | +| Feature Behavior | To filter a list of artifacts by by type or use | +| Expected Outcome | Application list of qualifying artifacts identified as a link to a readable file | +| Enabled Need | Open an artifact as a file for processing | + +## 7.8 Application Delete Cancelation + +| Variable | Value | +|-------------------------|----------------------------------------------------------------------------------------| +| Consumer | Systems Administrator | +| Feature Name | Cancel Application Delete | +| Feature Behavior | | +| Expected Outcome | Change the Application Package state to AVAILABLE and remove a scheduled deletion date | +| Enabled Need | Cancel a scheduled delete to extend the availability of the Application Package | + +# --- 8 Onboarding Service Requirements + +Not specified in this version of the specification. + +# --- 9 Onboarding Service Information Model + +Not specified in this version of the specification. + +# --- Annex A (informative): + +# --- Annex (informative): Change history/Change request (history) + + + + + + + +| Date | Revision | Description | +|------------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.06.24 | 00.00.01 | Create initial O-RAN version, from TS Template | +| 2024.11.12 | 00.00.02 | ATT-2024.07.08-WG10-CR-0001-OAM APP LCM Content-v05
ATT-2024.09.16-WG10-CR-0003-Scope Correction-v04 | +| 2024.11.12 | 00.00.03 | ATT-2024.09.16-WG10-CR-0004-Onboarding Use Cases-v02 | +| 2024.11.12 | 00.00.04 | General Aspects:
ATT-2024.09.16-WG10-CR-0005-GA ETSI Alignment-v04
ATT-2024.09.16-WG10-CR-0007-GA Distributed SMOS-v03
ATT-2024.09.16-WG10-CR-0008-GA Notifications-v02
ATT-2024.09.16-WG10-CR-0010-GA Reference vs Copy-v02
ATT-2024.09.18-WG10-CR-0011-GA Procedure Idempotence-v02
ATT-2024.09.18-WG10-CR-0012-GA Role Based Procedures-v02 | +| 2024.11.12 | 00.00.05 | Principles:
ATT-2024.09.18-WG10-CR-0013-Principle of Encapsulations-v04
Editorial Changes for publication | +| 2024.12.02 | 01.00 | Initial Published version | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..19f401a5cfbf08aa0ec7781203e69177a2b7e39d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5836b6268e1b6d229168b5e47faaaafd32832660ba85975f8ee7a6e10fc63fff +size 4560 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/0d724ff68bd941c2d91d7239a383c427_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/0d724ff68bd941c2d91d7239a383c427_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5f0467ce6174da6b6a96f73b9b473bbd27c017c8 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/0d724ff68bd941c2d91d7239a383c427_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1342451b6c8c734dce7d52ade11e90a59d9a528cf6c36db2939bbdcce76be8dc +size 22469 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/17398cfc35dde22fa5a80caabe669739_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/17398cfc35dde22fa5a80caabe669739_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ae115f85c71c7c4dd5ac246f8d02e9dc29c8af6 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/17398cfc35dde22fa5a80caabe669739_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c5775240b9ed1a2100a9c61aca08d03763ec191986acc2c52895232c0e85e48b +size 4429 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/1f41c33d59c2c353db34bfe6f762da48_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/1f41c33d59c2c353db34bfe6f762da48_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..65d439c66aeeb103e8c12393734dc08ef26614d4 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/1f41c33d59c2c353db34bfe6f762da48_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6c310b5378980d67cb6bcf76113eb788c5a3aad9b471182eb3be8a52b71125c2 +size 48981 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/21ca5f032ee8cfd7dbd7e9889837d2d8_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/21ca5f032ee8cfd7dbd7e9889837d2d8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8c3714bbd0681ec641247bc52b4193181ab01b3d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/21ca5f032ee8cfd7dbd7e9889837d2d8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:03e3029d96af91b558fef3bd347e5457e041795062b7ff11c8049f61cb52bc09 +size 46964 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/259441b671a699aff0bdccb5a284754a_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/259441b671a699aff0bdccb5a284754a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b517cfb23de2fe1d42584c2b4ffe322d68cae601 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/259441b671a699aff0bdccb5a284754a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6d771efc9e5155f40180b23ef0870ecc03b3fb8d6ebfc676864647bfda739c8d +size 4634 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/4228488bd5fd7673a8b2a838311a6847_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/4228488bd5fd7673a8b2a838311a6847_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f7c3e6290001c8e4e7352a727cd3b23bba96e3e7 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/4228488bd5fd7673a8b2a838311a6847_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c465c81291e9fef94eb7aca4d8112c6afb87033d926ee2cf4b9f7327c92d1ffc +size 127116 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/7389a894e5cf6aea4e1300a28dbc96e2_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/7389a894e5cf6aea4e1300a28dbc96e2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c1c37229e999197d69c400620498f60950c8fa91 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/7389a894e5cf6aea4e1300a28dbc96e2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:98b916a51aefe487bcbf866036cd31dec531d6125816412917be2aed57c83dae +size 124517 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/7ef350d1705d5873a21229206ed5a152_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/7ef350d1705d5873a21229206ed5a152_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..384180e2493fd97aa0f6b7ef64d03bdb3f07ca1d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/7ef350d1705d5873a21229206ed5a152_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:26c19d7317a3c87654fda2b461733742665fe20674502b07bb1db98b2605d1df +size 42364 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/912ad24d58749e2145fb818596096c1e_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/912ad24d58749e2145fb818596096c1e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9335558bdc8655cb7f310b0dce80d6398c94719c --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/912ad24d58749e2145fb818596096c1e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1bdf1fbe337a6acf3af3fc1f6d654cdcdf9b14c89ad150209b01a12918920345 +size 52499 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/9f2e86502cd5f7e352addc60736700a7_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/9f2e86502cd5f7e352addc60736700a7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5d540c8eda734484ba93caa999a03149cdfb414f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/9f2e86502cd5f7e352addc60736700a7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:38a4c8e6d9c67ff50113c24b9e7148ff0372a1f8d4c6214cc6e7ff8b42285582 +size 56187 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/c0bce93b20e223a45ba5c4c89ab814a9_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/c0bce93b20e223a45ba5c4c89ab814a9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a1cbccc6f497fa906be3ac88f27c192da9f6dfb5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/c0bce93b20e223a45ba5c4c89ab814a9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8b3388140434dc630cd8a9fd600ec8a969e28d66b6cd977f8d0426657cc53d5e +size 22039 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/d725f82ab07fd515f737065bc0862b72_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/d725f82ab07fd515f737065bc0862b72_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..012e30df74fb3d3010796c3b289dda72fe5b6e29 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/d725f82ab07fd515f737065bc0862b72_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:96bb12c3d1564dc4eee0625be8998bb37820349d2aa92ae86063263d6ea6fd2b +size 40854 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/f745c38ad4f908aaefc2bb1bd8bfc736_img.jpg b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/f745c38ad4f908aaefc2bb1bd8bfc736_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f79f7b2be1d5d99885d27a58ed7559de11d2b722 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/f745c38ad4f908aaefc2bb1bd8bfc736_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7ae2e7743f153b82c3ce93d7253b63d9acd28520f0ccc3753fb4f842cf9869ec +size 36708 diff --git a/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/raw.md b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..47710812b1ac17b97f906ca6d12a284394b7800b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00/raw.md @@ -0,0 +1,1502 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****Study on Security for Application Lifecycle Management** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +# Contents + +| | | +|---------------------------------------------------------------------------------|----| +| List of figures ..... | 4 | +| List of tables ..... | 4 | +| Foreword ..... | 5 | +| Modal verbs terminology ..... | 5 | +| Introduction ..... | 5 | +| 1 Scope..... | 6 | +| 2 References..... | 6 | +| 2.1 Informative references..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 8 | +| 3.1 Terms..... | 8 | +| 3.2 Symbols..... | 8 | +| 3.3 Abbreviations ..... | 8 | +| 4 Application Lifecycle Management background and assets ..... | 10 | +| 4.1 Introduction ..... | 10 | +| 4.2 Application Lifecycle..... | 10 | +| 4.3 Assets ..... | 11 | +| 5 Key issues ..... | 12 | +| 5.1 Introduction ..... | 12 | +| 5.2 Development of Application Package..... | 12 | +| 5.2.1 Key Issue Dev-1: Package Authenticity and Integrity ..... | 12 | +| 5.2.2 Key Issue Dev-2: Software Bill of Materials (SBOM) for Applications ..... | 12 | +| 5.2.3 Key Issue Dev-3: Security Descriptor..... | 13 | +| 5.3 Onboarding and Deployment of Application..... | 13 | +| 5.3.1 Key Issue Onboard-1: Initial Authentication of Application Package ..... | 13 | +| 5.3.2 Key Issue Onboard-2: Image Tampering during Application Onboarding ..... | 14 | +| 5.3.3 Key Issue Onboard-3: Risk of Deploying a Malicious Application..... | 14 | +| 5.3.4 Key Issue Onboard-4: rAppID Abuse ..... | 15 | +| 5.3.5 Key Issue Onboard-5: Registration of Applications ..... | 17 | +| 5.4 Operation and Maintenance of Application ..... | 17 | +| 5.4.1 Key Issue Op-1: Security for Application Updates ..... | 17 | +| 5.4.2 Key Issue Op-2: Application Integrity during Operation..... | 18 | +| 5.4.3 Key Issue Op-3: Security Logging and Monitoring of Applications ..... | 19 | +| 5.4.4 Key Issue Op-4: Secure Decommissioning of Applications ..... | 19 | +| 5.4.5 Key Issue Op-5: Exploitation of Application Vulnerabilities ..... | 20 | +| 5.4.6 Key Issue Op-6: PNF Software Lifecycle Security ..... | 20 | +| 5.4.7 Key Issue Op-7: Application Misconfiguration ..... | 21 | +| 5.4.8 Key Issue Op-8: Secure Deletion of Sensitive Data..... | 21 | +| 6 Potential Solutions ..... | 22 | +| 6.1 Solution #1: Application Package Authenticity and Integrity ..... | 22 | +| 6.1.1 Introduction ..... | 22 | +| 6.1.2 Solution details ..... | 22 | +| 6.2 Solution #2: Secure Update of Applications ..... | 23 | +| 6.2.1 Introduction ..... | 23 | +| 6.2.2 Solution details ..... | 23 | +| 6.3 Solution #3 Application Security Descriptor ..... | 24 | +| 6.3.1 Introduction ..... | 24 | +| 6.3.2 Solution details ..... | 25 | +| 6.4 Solution #4: Secure Logging and Monitoring for Applications..... | 29 | +| 6.4.1 Introduction ..... | 29 | +| 6.4.2 Solution details ..... | 29 | + +| | | | +|--------|-------------------------------------------------------------------------------|----| +| 6.5 | Solution #5: Software Bill of Materials Requirement for Applications ..... | 30 | +| 6.5.1 | Introduction ..... | 30 | +| 6.5.2 | Solution details ..... | 30 | +| 6.6 | Solution #6: Recommendations for Vulnerability Scanning..... | 30 | +| 6.6.1 | Introduction ..... | 30 | +| 6.6.2 | Solution details ..... | 30 | +| 6.7 | Solution #7: Recommendations for Addressing Application Vulnerabilities ..... | 31 | +| 6.7.1 | Introduction ..... | 31 | +| 6.7.2 | Solution details ..... | 31 | +| 6.8 | Solution #8: PNF Software Lifecycle Security Recommendations ..... | 32 | +| 6.8.1 | Introduction ..... | 32 | +| 6.8.2 | Solution details ..... | 32 | +| 6.9 | Solution #9: Application Integrity during Operation ..... | 34 | +| 6.9.1 | Introduction ..... | 34 | +| 6.9.2 | Solution details ..... | 34 | +| 6.10 | Solution #10: Secure Decommissioning of Applications ..... | 35 | +| 6.10.1 | Introduction ..... | 35 | +| 6.10.2 | Solution details ..... | 35 | +| 6.11 | Solution #11: Secure Deletion of Sensitive Data ..... | 35 | +| 6.11.1 | Introduction ..... | 35 | +| 6.11.2 | Solution details ..... | 35 | +| 6.12 | Solution #12: rAppID Uniqueness ..... | 36 | +| 6.12.1 | Introduction ..... | 36 | +| 6.12.2 | Solution Details ..... | 37 | +| 6.13 | Solution #13: Secure Application Registration Procedure..... | 37 | +| 6.13.1 | Introduction ..... | 37 | +| 6.13.2 | Solution Details ..... | 37 | +| 7 | Conclusions..... | 39 | +| 7.1 | Key Issue Solution Mapping..... | 39 | +| 7.2 | Recommendations ..... | 40 | +| | History ..... | 41 | + +# --- List of figures + +| | | +|-----------------------------------------------------------------------------|----| +| Figure 4.1-1: SDLC Model [4]..... | 10 | +| Figure 4.2-1: Application Lifecycle Phases [4] ..... | 11 | +| Figure 6.1-1 Application package authenticity and integrity protection..... | 23 | +| Figure 6.2-1 Application update authenticity and integrity protection ..... | 24 | +| Figure 6.3-1: Application Package High Level Model from WG10 OAM [4]..... | 25 | +| Figure 6.3-2: Application interconnection ..... | 25 | +| Figure 6.13-1: Registration process for rApps ..... | 37 | +| Figure 6.13-2: Registration process for xApps ..... | 38 | + +# --- List of tables + +| | | +|----------------------------------------------------------|----| +| Table 6.3-1: Security group rules descriptor..... | 26 | +| Table 6.3-2: SAL requirements descriptor ..... | 28 | +| Table 6.4-1: Application LCM Logging Event Coverage..... | 29 | +| Table 6.8-1: Recommended security mechanisms ..... | 32 | +| Table 7.1-1 - Mapping of Key Issues to Solutions..... | 39 | + +# --- Foreword + +This Technical Report (TR) has been produced by the O-RAN Alliance. + +--- + +## Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Introduction + +This technical report focuses on the security of O-RAN applications during their lifecycle phases as defined in WG10 OAM Architecture [4]: development, onboarding, and operation. O-RAN applications in the scope of this technical report include xApps, rApps, VNFs/CNFs such as O-CU, O-DU, O-RU, and Near-RT RIC, as well as software for physical network functions such as O-RU and O-DU. + +The technical report takes into consideration the threats identified in the O-RAN Threat Modeling and Risk Assessment TR [1] and develops a list of key issues from this. The key issues relating to application life cycle management are divided into the appropriate lifecycle phase and include a description, security threats, and potential requirements to mitigate these threats. Solutions are proposed to address the key issues. The conclusion clause contains a mapping between key issues and solutions, as well as additional recommendations. + +The order of the clauses of this document is as follows: + +1. Scope +2. References +3. Definition of terms, symbols, and abbreviations +4. Application LCM background and assets +5. Key Issues +6. Potential Solutions +7. Conclusions + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +This technical report is the study of security of applications throughout the lifecycle management phases (development, onboarding, and operation) + +Taking into consideration the threats and risks identified in O-RAN Threat Modeling and Risk Assessment TR [1], this study analyzes a list of key issues for applications during their lifecycle in order to derive security requirements, intended to be part of O-RAN Security Requirements and Controls Specifications [2]. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +[1] O-RAN ALLIANCE TR, “O-RAN Security Threat Modeling and Risk Assessment” + +[2] O-RAN ALLIANCE TS, “O-RAN Security Requirements and Controls Specifications” + +[3] O-RAN ALLIANCE TS, “O-RAN Architecture Description” + +[4] O-RAN ALLIANCE TS, “O-RAN OAM Architecture” + +[5] O-RAN ALLIANCE TS, “O-RAN Information Model and Data Models” + +[6] “The Minimum Elements for a Software Bill of Materials (SBOM), Pursuant to Executive Order 14028 on Improving the Nation’s Cybersecurity”, U.S. DoC and NTIA, July 2021. + +[7] The MITRE Corporation, “MITRE ATT&CK® Containers Matrix”, Accessed on 03 AUG 2022, + +[8] The MITRE Corporation, “MITRE FIGHT™ Matrix”, Accessed on 16 AUG 2022, + +[9] O-RAN ALLIANCE TS, “O-RAN R1 Interface: Use Cases and Requirements” + +[10] O-RAN ALLIANCE TS, “O-RAN Near-RT RIC Architecture” + +- [11] ETSI GS NFV-IFA 011 - VNF Descriptor and Packaging Specification, +[https://www.etsi.org/deliver/etsi\\_gs/NFV-IFA/001\\_099/011/04.02.01\\_60/gs\\_NFV-IFA011v040201p.pdf](https://www.etsi.org/deliver/etsi_gs/NFV-IFA/001_099/011/04.02.01_60/gs_NFV-IFA011v040201p.pdf) +- [12] IANA Protocol Registries, +- [13] The "Fossies" Software Archive – VNFD TOSCA template +[https://fossies.org/linux/tacker/samples/vnf\\_packages/Definitions/etsi\\_nfv\\_sol001\\_vnfd\\_types.yaml](https://fossies.org/linux/tacker/samples/vnf_packages/Definitions/etsi_nfv_sol001_vnfd_types.yaml) +- [14] O-RAN ALLIANCE TR, “O-RAN Study on Security Log Management” +- [15] NISTIR 8397, Guidelines on Minimum Standards for Developer Verification of Software, 2021. + +- [16] NIST SP 800-53r5, Security and Privacy Controls for Information Systems and Organizations, 2020. + +- [17] Enduring Security Framework (ESF) Securing the Software Supply Chain, Recommended Practices Guide for Developers, 2022 +- [18] OpenSSF FLOSS Best Practices Criteria, +- [19] OpenSSF Concise Guide for Developing More Secure Software, +- [20] Enduring Security Framework (ESF) Securing the Software Supply Chain, Recommended Practices Guide for Suppliers, 2022 +- [21] Center for Internet Security (CIS) Critical Security Controls, +- [22] O-RAN ALLIANCE TS, “O-RAN Management Plane Specification” +- [23] O-RAN ALLIANCE TS, “O-RAN Operations and Maintenance Interface Specification” +- [24] Cybersecurity & Infrastructure Security Agency (CISA) Known Exploited Vulnerabilities Catalog, + +- [25] O-RAN ALLIANCE TS, “Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN” +- [26] ETSI GS NFV-SEC 021, VNF Package Security Specification, [https://www.etsi.org/deliver/etsi\\_gs/NFV-SEC/001\\_099/021/02.06.01\\_60/gs\\_nfv-sec021v020601p.pdf](https://www.etsi.org/deliver/etsi_gs/NFV-SEC/001_099/021/02.06.01_60/gs_nfv-sec021v020601p.pdf) +- [27] O-RAN ALLIANCE TS, “O-RAN Security Test Specifications” +- [28] “Six Steps Toward Better Application Decommissioning”, +- [29] Enduring Security Framework (ESF) Securing the Software Supply Chain, Recommended Practices Guide for Customers, 2022 +- [30] NIST SP 800-88 R1, Guidelines for Media Sanitization, 2014. +- [31] ETSI GS NFV-SEC 013, NFV Security; Security Management and Monitoring specification +- [32] RFC 4122: A Universally Unique IDentifier (UUID) URN Namespace. +- [33] O-RAN ALLIANCE TR: “Study on Security for Near Real Time RIC and xApps” +- [34] O-RAN ALLIANCE TS, “O-RAN Non-RT RIC Architecture” + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions provided in O-RAN Architecture Description [3] and O-RAN Operations and Maintenance Architecture [4] apply: + +**Application Package:** The basic unit exchanged between the Solution Provider and Service Provider. + +**Near-RT RIC:** O-RAN Near-Real-Time RAN Intelligent Controller: A logical function that enables near-real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. It may include AI/ML (Artificial Intelligence / Machine Learning) workflow including model training, inference and updates. + +**Non-RT RIC:** O-RAN Non-Real-Time RAN Intelligent Controller: A logical function within SMO that drives the content carried across the A1 interface. It is comprised of the Non-RT RIC Framework and the Non-RT RIC Applications (rApps) whose functions are defined below. + +**Non-RT RIC Applications (rApps):** Modular applications that leverage the functionality exposed via the Non-RT RIC Framework's R1 interface to provide added value services relative to RAN operation, such as driving the A1 interface, recommending values and actions that may be subsequently applied over the O1/O2 interface and generating "enrichment information" for the use of other rApps. The rApp functionality within the Non-RT RIC enables non-real-time control and optimization of RAN elements and resources and policy-based guidance to the applications/features in Near-RT RIC. + +**O-Cloud:** O-Cloud is a cloud computing platform comprising a collection of physical infrastructure nodes that meet O-RAN requirements to host the relevant O-RAN functions (such as Near-RT RIC, O-CU-CP, O-CU-UP, and O-DU), the supporting software components (such as Operating System, Virtual Machine Monitor, Container Runtime, etc.) and the appropriate management and orchestration functions. + +**rApp instance:** An individual occurrence of an application running in the Non-RT RIC runtime environment. [34] + +**rApp instance identifier:** A unique identifier for each rApp instance, assigned by the SMO/Non-RT RIC framework during rApp registration. [34] + +**Service Planning:** Activities internal to the Service Provider + +**Service Provider:** A network provider who is planning to deploy applications into their network. + +**Solution Provider:** An application developer who delivers applications to Service Providers. + +**SP Exchange:** Not a formal interface in terms of between systems. However, the structure and content of the exchange is defined such that a Solution Provider can deliver applications to a Service Provider for deployment. + +**xApps:** Applications designed to run on the Near-RT RIC. Such an application is likely to consist of one or more microservices and at the point of on-boarding will identify which data it consumes and which data it provides. The application is independent of the Near-RT RIC and may be provided by any third party. The E2 enables a direct association between the xApp and the RAN functionality. + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +## 3.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply: + +| | | +|------------|------------------------------------------| +| AI/ML | Artificial Intelligence/Machine Learning | +| API | Application Programming Interface | +| AppPackage | Application Package | + +| | | +|---------|-------------------------------------------------| +| CNF | Cloud-native Network Function | +| eNB | eNodeB (applies to LTE) | +| gNB | gNodeB (applies to NR) | +| KPI | Key Performance Indicator | +| LCM | Lifecycle Management | +| ML | Machine Learning | +| MNO | Mobile Network Operator | +| NF | Network Function | +| NFV | Network Function Virtualisation | +| O-CU | O-RAN Central Unit as defined by O-RAN ALLIANCE | +| O-CU-CP | O-CU Control Plane | +| O-CU-UP | O-CU User Plane | +| O-DU | O-RAN Distributed Unit (uses Lower-level Split) | +| O-RU | O-RAN Radio Unit | +| RAN | Radio Access Network | +| rAppId | rApp Instance Identifier | +| RIC | O-RAN RAN Intelligent Controller | +| SBOM | Software Bill of Materials | +| SDLC | Software Development Lifecycle | +| SMO | Service Management and Orchestration | +| VM | Virtual machine | +| VNF | Virtualised Network Function | + +# 4 Application Lifecycle Management background and assets + +## 4.1 Introduction + +Lifecycle Management of applications deployed in O-RAN follows standard Software Development Lifecycle (SDLC) basic models. Figure 4.1-1 depicts the model that applications described in this document generally follow. The states in this SDLC model can be generally classified into three categories: Development, Onboarding, and Operation. Two entities involved in Lifecycle Management are the Solution Provider and the Service Provider. A Solution Provider provides the application that fulfils the requirements and needs of a Service Provider, who deploys the application on the platform. The basic unit exchanged between the Solution Provider and Service Provider is the Application package (AppPackage). The AppPackage contains data including the application itself, as well as its descriptors. For more details on the AppPackage, please refer to [4]. + +![Figure 4.1-1: SDLC Model [4]. A circular diagram showing the Software Development Lifecycle (SDLC) model. The diagram is divided into two main sections: 'Service Provider' at the top and 'Solution Provider' at the bottom. The cycle consists of seven stages: 'Needs' (orange, top right), 'Ideation' (grey, top right), 'Analysis' (yellow, bottom right), 'Develop' (blue, bottom), 'Deliver' (green, bottom left), 'Validate' (orange, top left), and 'Operate' (grey, top left). Arrows indicate a clockwise flow between these stages.](c0bce93b20e223a45ba5c4c89ab814a9_img.jpg) + +Figure 4.1-1: SDLC Model [4]. A circular diagram showing the Software Development Lifecycle (SDLC) model. The diagram is divided into two main sections: 'Service Provider' at the top and 'Solution Provider' at the bottom. The cycle consists of seven stages: 'Needs' (orange, top right), 'Ideation' (grey, top right), 'Analysis' (yellow, bottom right), 'Develop' (blue, bottom), 'Deliver' (green, bottom left), 'Validate' (orange, top left), and 'Operate' (grey, top left). Arrows indicate a clockwise flow between these stages. + +Figure 4.1-1: SDLC Model [4] + +## 4.2 Application Lifecycle + +The three application lifecycle phases defined in [4] are Development, Onboarding, and Operation. Development involves the creation of the application, preparation, and delivery from Solution Provider to Service Provider. Onboarding consists of the onboarding of the application onto its ultimate runtime environment. Some activities included in this phase are establishment of configurations, content verification, and app/AppPackage cataloguing. Operation encompasses the runtime of the application. In this phase, applications are deployed, updated, monitored, managed and ultimately after some analysis, either terminated or healed/scaled. + +![Figure 4.2-1: Application Lifecycle Phases [4]. The diagram shows three main phases: 'App Development', 'App Onboarding', and 'App Operation'. 'App Development' includes Ideation, Analysis, Development, and Delivery. 'App Onboarding' includes Onboarding and Validation. 'App Operation' includes Management and Monitoring. Arrows show the flow from Development to Onboarding (labeled 'App/Model Package') and from Onboarding to Operation (labeled 'App/Model Catalogue'). A feedback loop arrow at the bottom connects the Operation phase back to the Development phase, labeled 'Needs/Sample Data/Feedback/Optimization request'.](d725f82ab07fd515f737065bc0862b72_img.jpg) + +``` + +graph LR + subgraph "App Development" + A[Ideation] + B[Analysis] + C[Development] + D[Delivery] + end + subgraph "App Onboarding" + E[Onboarding] + F[Validation] + end + subgraph "App Operation" + G[Management] + H[Monitoring] + end + "App Development" -- "App/Model Package" --> "App Onboarding" + "App Onboarding" -- "App/Model Catalogue" --> "App Operation" + "App Operation" -- "Needs/Sample Data/Feedback/Optimization request" --> "App Development" + +``` + +Figure 4.2-1: Application Lifecycle Phases [4]. The diagram shows three main phases: 'App Development', 'App Onboarding', and 'App Operation'. 'App Development' includes Ideation, Analysis, Development, and Delivery. 'App Onboarding' includes Onboarding and Validation. 'App Operation' includes Management and Monitoring. Arrows show the flow from Development to Onboarding (labeled 'App/Model Package') and from Onboarding to Operation (labeled 'App/Model Catalogue'). A feedback loop arrow at the bottom connects the Operation phase back to the Development phase, labeled 'Needs/Sample Data/Feedback/Optimization request'. + +Figure 4.2-1: Application Lifecycle Phases [4] + +## 4.3 Assets + +The assets within scope of this study are Application Packages for virtualized network functions (i.e., O-CU, O-DU, O-RU\*, and Near-RT RIC), xApps, rApps, and software packages for physical network functions (i.e., O-RU and O-DU). This aligns with WG10 Application Lifecycle Management [4]. + +\* O-RU is considered a physical device in current O-RAN architecture [3] but may be virtualized in future deployment scenarios [25]. + +The application packages include the following assets already defined in [1]: + +- Data assets: + - ASSET-D-15: Application software package + - ASSET-D-23: Patches for vulnerable SW components + - Secure stores: + - ASSET-D-16: X.509 certificates + - ASSET-D-17: Private keys + - ASSET-D-32: Cryptographic keys used during secure boot + - AI/ML Data: + - ASSET-D-25: Training or test data + - ASSET-D-26: The trained ML model + - ASSET-D-27: The ML prediction results built into the model + - ASSET-D-28: The behaviour of the ML system +- Components: + - ASSET-C-02: Near-RT RIC software + - ASSET-C-03: O-CU-CP software + - ASSET-C-04: O-CU-UP software + - ASSET-C-05: O-DU software + - ASSET-C-06: O-RU software + - ASSET-C-09: xApps + - ASSET-C-10: rApps + - ASSET-C-11: Non-RT RIC software + +Software for PNFs is included in this study to the extent of defining high-level security requirements for the software package. Management for PNFs, to include PNF registration and management, is out of scope for this study. PNF registration and management is an important topic and may require additional security analysis when the 3GPP specifications are adopted by O-RAN [5]. + +NOTE: ‘Application’ in this document refers to xApps, rApps, O-CU, etc. and could be implemented as a VNF or CNF. Software for PNFs is not included in this definition and will still be referred to as “PNF” or “PNF software package”. + +# 5 Key issues + +## 5.1 Introduction + +This clause details the key issues identified for security aspects related to application lifecycle management, subdivided into the LCM areas of 1) Development of Application Package, 2) Onboarding and Deployment of Application, and 3) Operation and Maintenance of Application. Each key issue details the general description of the key issue, defines the threats related to the issue, and proposes requirements that resolve or mitigate the key issue. + +## 5.2 Development of Application Package + +### 5.2.1 Key Issue Dev-1: Package Authenticity and Integrity + +#### 5.2.1.1 General description + +The Solution Provider is responsible for creating an application that fulfils the needs of a Service Provider. An Application package delivered to the Service Provider that goes unverified in terms of authenticity and integrity is subject to multiple threats. For example, the Service Provider may unintentionally deploy an application that is either not actually provided by the Solution Provider, or that is from the Solution Provider but its integrity was compromised during transit. Such an occurrence may disrupt Service Provider operation and/or present security risks. + +#### 5.2.1.2 Security threats + +The security threats associated with Package Authenticity and Integrity are: + +- Malicious actor replacing the Service Provider's package with their own package +- Service disruption caused by deploying an application with degraded functionality caused by compromise of Application package integrity +- Insider threat + +The following threat(s) from [1] are applicable to Dev-1: + +- T-O-RAN-09: An attacker compromises O-RAN components integrity and availability +- T-IMG-01: VM/Container images tampering +- T-NEAR-RT-02: Risk of deployment of a malicious xApp on Near-RT RIC +- T-rApp-05: An attacker deploys and exploits malicious rApp + +#### 5.2.1.3 Potential security requirements + +The following security requirements from [2] involving Application software package protection are proposed to mitigate the threats stemming from the key issue of package authenticity and integrity. + +- REQ-SEC-ALM-PKG-2 +- REQ-SEC-ALM-PKG-3 +- REQ-SEC-ALM-PKG-4 +- REQ-SEC-ALM-PKG-5 + +### 5.2.2 Key Issue Dev-2: Software Bill of Materials (SBOM) for Applications + +#### 5.2.2.1 General description + +Software bill of materials for O-RAN software products is an important part of the software development process and applies also to the application life cycle process. SBOMs document the software used in software products in order to understand the software supply chain for proper notification of vulnerabilities and updates. + +#### 5.2.2.2 Security threats + +The security threats that arise from not properly documenting software products via an SBOM includes: + +- Lack of process to detect known software vulnerabilities and lack of accountability for notification + +The following threat(s) from [1] are applicable to Dev-2: + +- T-GEN-01: Software flaw attack +- T-OPENSRC-01: Developers use SW components with known vulnerabilities and untrusted libraries that can be exploited by an attack through a backdoor attack + +#### 5.2.2.3 Potential security requirements + +Clause 6 of the WG11 Security Requirements and Controls Specifications [2] provides SBOM guidelines and requirements for O-RAN, based on guidance from NTIA [6]. This covers requirements on the minimum data fields and depth for SBOMs for O-RAN software. + +An additional potential requirement could explicitly state that application packages also need SBOMs from the application provider with the same fields and to the same depth as other O-RAN software products are specified. + +### 5.2.3 Key Issue Dev-3: Security Descriptor + +#### 5.2.3.1 General description + +WG10 has proposed a SecurityDescriptor in the Application Package, to be reviewed by WG11 to ensure all security aspects are being considered and it is in line with WG11 requirements. + +#### 5.2.3.2 Security threats + +The following threat(s) are applicable to Dev-3: + +- Missing or improperly defined elements of the SecurityDescriptor, such as information regarding the application certificate and security rules, could lead to unauthorized access to data and services. + +#### 5.2.3.3 Potential security requirements + +Proper and comprehensive definition of the SecurityDescriptor helps ensure elements of security needed for the Application package are present. + +The SecurityDescriptor is part of the Application package and therefore it should be protected in terms of authenticity and integrity. + +## 5.3 Onboarding and Deployment of Application + +### 5.3.1 Key Issue Onboard-1: Initial Authentication of Application Package + +#### 5.3.1.1 General description + +After the Application package has been delivered from the Solution Provider to the Service Provider, preparation for application deployment commences where it goes through the Onboarding phase prior to deployment. If the application is unauthenticated during onboarding, Service Providers can unintentionally deploy an application that can cause harm to their platforms. Depending on the platform, the unauthenticated application could be also used by a threat actor to perform malicious activities on the Near-RT RIC, Non-RT RIC, and O-Cloud platforms. + +#### 5.3.1.2 Security threats + +The security threats associated with Initial Authentication of Application package are: + +- Unauthenticated application onboarded in the O-Cloud Image Repository +- Unauthenticated application running on the Service Provider/SMO platform + +The following threat(s) from [1] are applicable to Onboard-1: + +- T-O-RAN-06: An attacker exploits insufficient/improper mechanisms for authentication and authorization to compromise O-RAN components +- T-O-RAN-08: An attacker compromises O-RAN data integrity, confidentiality and traceability +- T-O-RAN-09: An attacker compromises O-RAN components integrity and availability +- T-IMG-01: VM/Container images tampering +- T-NEAR-RT-02: Risk of deployment of a malicious xApp on Near-RT RIC +- T-xApp-01: An attacker exploits xApp vulnerabilities and misconfigurations +- T-rApp-05: An attacker deploys and exploits malicious rApp + +#### 5.3.1.3 Potential security requirements + +The following security requirements from [2] involving Application software package protection are proposed to mitigate the threats stemming from the key issue of initial authentication of application/VNF. + +- REQ-SEC-ALM-PKG-2 +- REQ-SEC-ALM-PKG-3 +- REQ-SEC-ALM-PKG-4 +- REQ-SEC-ALM-PKG-5 + +### 5.3.2 Key Issue Onboard-2: Image Tampering during Application Onboarding + +#### 5.3.2.1 General description + +An attacker can inject malicious code or tamper with the information in the Application package during onboarding. After instantiation of the application, the tampered code can cause DoS, information stealing, etc. + +#### 5.3.2.2 Security threats + +The following threat(s) from [1] are applicable to Onboard-2: + +- T-O-RAN-09: An attacker compromises O-RAN components integrity and availability +- T-IMG-01: VM/Container images tampering + +#### 5.3.2.3 Potential security requirements + +The following security requirements from [2] involving Application software package protection are proposed to mitigate the threats stemming from the key issue of image tampering during onboarding. + +- REQ-SEC-ALM-PKG-7a, 7b, 7c +- REQ-SEC-ALM-PKG-12 +- REQ-SEC-ALM-PKG-13 + +### 5.3.3 Key Issue Onboard-3: Risk of Deploying a Malicious Application + +#### 5.3.3.1 General description + +Deploying a malicious application can negatively affect the O-RAN platform and its functions. Malicious xApps can impact radio service and provide unauthorized access to subscriber information. Malicious rApps may disrupt offered + +network service and affect Non-RT RIC functions. Malicious code in VM/Container images can cause DoS, information stealing, etc., when the VNF/CNF is instantiated. + +#### 5.3.3.2 Security threats + +The following threat(s) from [1] are applicable to Onboard-3: + +- T-rApp-05: An attacker deploys and exploits malicious rApp +- T-NEAR-RT-01: Malicious xApps can exploit UE identification, track UE location and change UE priority +- T-IMG-01: VM/Container images tampering + +#### 5.3.3.3 Potential security requirements + +The following security requirements from [2] involving Application software package protection are proposed to help mitigate the threats stemming from the key issue of the risk of deploying a malicious application. Properly verifying authenticity and integrity of the Application package and testing the package for known vulnerabilities help address the threats from deploying a malicious application. + +- REQ-SEC-ALM-PKG-2 +- REQ-SEC-ALM-PKG-3 +- REQ-SEC-ALM-PKG-4 +- REQ-SEC-ALM-PKG-5 +- REQ-SEC-ALM-PKG-7a, 7b, 7c + +### 5.3.4 Key Issue Onboard-4: rAppID Abuse + +#### 5.3.4.1 General Description + +The rAppID is assigned to an rApp instance during rApp registration, which occurs after the onboarding and instantiation of the rApp as described in [9] and shown in Figure 5.3-1. + +![Sequence diagram showing the assignment of rAppID during rApp registration process. The diagram is divided into two main sections: 'bootstrap' and 'rApp registration'. In the 'bootstrap' section, an rApp (yellow box) sends a '1 <>Bootstrap request' to SME functions (blue box), which responds with '2 <>Bootstrap response'. In the 'rApp registration' section, the rApp sends a '3 <>Registration request' to SME functions. SME functions then perform '4 AuthN' and 'registration processing assign rAppID' (highlighted in a green box). Finally, SME functions send a '5 <>Registration response (rAppID)' back to the rApp.](9f2e86502cd5f7e352addc60736700a7_img.jpg) + +``` + +sequenceDiagram + participant rApp as rApp + participant SME as SME functions + participant NonRT as Non-RT RIC + participant Framework as Non-anchored functions in SMO/Non-RT RIC Framework + + Note over rApp, SME: bootstrap + rApp->>SME: 1 <>Bootstrap request + SME-->>rApp: 2 <>Bootstrap response + + Note over rApp, SME: rApp registration + rApp->>SME: 3 <>Registration request + SME->>SME: 4 AuthN + SME->>SME: registration processing assign rAppID + SME-->>rApp: 5 <>Registration response (rAppID) + +``` + +Sequence diagram showing the assignment of rAppID during rApp registration process. The diagram is divided into two main sections: 'bootstrap' and 'rApp registration'. In the 'bootstrap' section, an rApp (yellow box) sends a '1 <>Bootstrap request' to SME functions (blue box), which responds with '2 <>Bootstrap response'. In the 'rApp registration' section, the rApp sends a '3 <>Registration request' to SME functions. SME functions then perform '4 AuthN' and 'registration processing assign rAppID' (highlighted in a green box). Finally, SME functions send a '5 <>Registration response (rAppID)' back to the rApp. + +Figure 5.3-1: Assignment of rAppID during rApp registration process [9] + +The rAppID is used to identify the rApp to the Service Management and Exposure (SME) or Data Management and Exposure (DME) services during use cases such as service registration, service discovery, data type discovery, and + +subscribing for service availability. Figures 5.3-2 and 5.3-3 depict examples of R1 use cases from [9] where the rAppID is sent to the SME or DME respectively to identify the rApp making the request. The rAppID may be one of the mechanisms used for authorization of an rApp for certain use cases. + +![Figure 5.3-2: Register service use case flow diagram (rAppID to SME) [9]. The diagram shows a sequence of messages between an rApp and SME functions within the Non-RT RIC framework. Step 1: rApp sends '<>Register service request (rAppId, service profile)' to SME functions. Step 2: SME functions perform 'AuthZ' with a note 'check authorization to register a service'. Step 3: SME functions perform 'Validate'. Step 4: SME functions perform 'register service'. Step 5: SME functions send '<>Register service response (service identifier)' back to the rApp.](f745c38ad4f908aaefc2bb1bd8bfc736_img.jpg) + +Figure 5.3-2: Register service use case flow diagram (rAppID to SME) [9]. The diagram shows a sequence of messages between an rApp and SME functions within the Non-RT RIC framework. Step 1: rApp sends '<>Register service request (rAppId, service profile)' to SME functions. Step 2: SME functions perform 'AuthZ' with a note 'check authorization to register a service'. Step 3: SME functions perform 'Validate'. Step 4: SME functions perform 'register service'. Step 5: SME functions send '<>Register service response (service identifier)' back to the rApp. + +Figure 5.3-2: Register service use case flow diagram (rAppID to SME) [9] + +![Figure 5.3-3: Discover data type use case flow diagram (rAppID to DME) [9]. The diagram shows a sequence of messages between an rApp and Data management and exposure functions within the Non-RT RIC framework. Step 1: rApp sends '<>Discover data type identifiers request (rAppId, Query information)' to Data management and exposure functions. Step 2: Data management and exposure functions perform 'AuthZ' with a note 'Check authorization in collaboration with SME functions'. Step 3: Data management and exposure functions send '<>Discover data type identifiers response (data type identifiers and metadata)' back to the rApp.](21ca5f032ee8cfd7dbd7e9889837d2d8_img.jpg) + +Figure 5.3-3: Discover data type use case flow diagram (rAppID to DME) [9]. The diagram shows a sequence of messages between an rApp and Data management and exposure functions within the Non-RT RIC framework. Step 1: rApp sends '<>Discover data type identifiers request (rAppId, Query information)' to Data management and exposure functions. Step 2: Data management and exposure functions perform 'AuthZ' with a note 'Check authorization in collaboration with SME functions'. Step 3: Data management and exposure functions send '<>Discover data type identifiers response (data type identifiers and metadata)' back to the rApp. + +Figure 5.3-3: Discover data type use case flow diagram (rAppID to DME) [9] + +An adversary may obtain a legitimate rAppID and use it to gain unauthorized access to services and data. Accidental or intentional use of non-unique identifiers for the rAppID can cause operational problems. Duplicate rAppIDs may cause services to be unavailable to the rApps requesting the service and be provided to rApps not needing the service (in the case of multiple rApps having the same rAppID). + +NOTE: Security for IDs for xApps has also been studied in the Near-RT RIC and xApp security technical report [33], with similar threats, requirements, and solution noted. The rAppID Abuse key issue and corresponding solution (clause 6.12) considers existing xApp ID security work. + +#### 5.3.4.2 Security Threats + +The security threats associated with rAppID abuse are: + +- rAppID collisions +- Unauthorized access to R1 services and data + +#### 5.3.4.3 Potential Security Requirements + +The Non-RT RIC should create each rAppID using procedures that avoid duplicates. One example of this is UUID as described in IETF RFC 4122. + +### 5.3.5 Key Issue Onboard-5: Registration of Applications + +#### 5.3.5.1 General Description + +During deployment of xApps and rApps, the registration procedure occurs where the applications are registered to the Near-RT RIC platform or Non-RT RIC/SMO Framework respectively. During both registration procedures, the application is authenticated before it is assigned an ID. For more information about the application registration processes, refer to WG2 R1 Use Cases [9] for rApps and WG3 RICARCH [10] for xApps. Application package signatures are checked before registration during onboarding and deployment, but there can be a delay between onboarding and registration of the application which necessitates a validation during the registration phase. The location where the application is instantiated may also be different from the location of onboarding, so application validation at registration may be able to detect potential modifications. + +#### 5.3.5.2 Security Threats + +The following threat(s) from [1] are applicable to Onboard-5: + +- T-O-RAN-06: An attacker exploits insufficient/improper mechanisms for authentication and authorization to compromise O-RAN components +- T-O-RAN-09: An attacker compromises O-RAN components integrity and availability +- T-NEAR-RT-02: Risk of deployment of a malicious xApp on Near-RT RIC +- T-rApp-05: An attacker deploys and exploits malicious rApp + +#### 5.3.5.3 Potential security requirements + +The following security requirement is proposed to mitigate the threats stemming from the key issue of application registration: + +- Application package should be authenticity and integrity checked during registration. + +## 5.4 Operation and Maintenance of Application + +### 5.4.1 Key Issue Op-1: Security for Application Updates + +#### 5.4.1.1 General description + +According to OAM architecture [4], the update process is an orchestrated process of deploy and terminate, and it is possible for two versions of an application to be active at the same time. Examples of situations where an update may be made available are when new features are introduced for the application or when the update addresses a vulnerability. In any situation where the application is updated, it must be ensured that the update is delivered, onboarded, and deployed in a secure manner involving authentication and integrity checks. + +The timeline for an update will remain a Service Provider implementation decision, although Service Providers should prioritize security updates and apply critical ones in a timely manner. + +#### 5.4.1.2 Security threats + +The security threats associated with Security for Application Updates are: + +- Malicious actor replacing the Service Provider's package with their own package +- Service disruption caused by deploying an application with degraded functionality caused by compromise of Application package integrity +- Insider threat + +The following threats from [1] are applicable to Op-1: + +- T-O-RAN-01: An attacker exploits insecure designs or lack of adoption in O-RAN components +- T-O-RAN-06: An attacker exploits insufficient/improper mechanisms for authentication and authorization to compromise O-RAN components +- T-O-RAN-08: An attacker compromises O-RAN data integrity, confidentiality and traceability +- T-O-RAN-09: An attacker compromises O-RAN components integrity and availability +- T-IMG-01: VM/Container images tampering +- T-NEAR-RT-02: Risk of deployment of a malicious xApp on Near-RT RIC +- T-xApp-01: An attacker exploits xApp vulnerabilities and misconfigurations +- T-rApp-05: An attacker deploys and exploits malicious rApp + +#### 5.4.1.3 Potential security requirements + +NOTE: The security requirements from [2] involving authentication of application by Solutions Providers and Service Providers is proposed to mitigate the key issue of onboarding a malicious application. These same requirements should be applied to address security threats of onboarding an update to an existing application. This is due to updates to applications being treated in the same manner as an application's initial installation onto its respective platform in terms of delivery, onboarding, and deployment. + +- REQ-SEC-ALM-PKG-2 +- REQ-SEC-ALM-PKG-3 +- REQ-SEC-ALM-PKG-4 +- REQ-SEC-ALM-PKG-5 +- REQ-SEC-ALM-PKG-7a, 7b, 7c + +### 5.4.2 Key Issue Op-2: Application Integrity during Operation + +#### 5.4.2.1 General description + +The operation and maintenance phase of the application represents an opportunity for malicious actors to negatively affect the O-RAN platform. While an application is running on its respective platform, it may be susceptible to malicious activities such as the overwriting of the application. Vulnerabilities in the application could also be exploited to execute malicious behavior. Verifying the integrity of running applications could ensure no modifications were made to introduce malicious behavior into the applications. + +#### 5.4.2.2 Security threats + +Examples of security threats associated with xApp integrity during operation are: + +- Vulnerabilities in trusted xApps (T-xApp-01) +- Security misconfiguration (T-xApp-01) +- Compromise of xApp isolation (T-xApp-03) + +Examples of the security threats associated with rApp integrity during operation are: + +- Exploitation of services across R1 interface (T-rAPP-07) +- Security misconfiguration (T-rAPP-03) + +Examples of the security threats associated with VNF/CNF integrity during operation are: + +- VM/Container escape (T-VM-C-02) +- VM/Container data theft (T-VM-C-03) +- Changing virtualization resources without authorization (T-VM-C-05) + +Other threats during runtime operation include: + +- Buffer overflow (T-O-RAN-01) + +#### 5.4.2.3 Potential security requirements + +- Integrity of running applications should be periodically verified by comparing the cryptographic hash of the application with a known good hash. + +### 5.4.3 Key Issue Op-3: Security Logging and Monitoring of Applications + +#### 5.4.3.1 General description + +Security logging and monitoring for applications needs to be properly defined so that threats during the application lifecycle management process can be detected. + +#### 5.4.3.2 Security threats + +The following security threats are an example of threats that could be detected by logging a comprehensive set of security events: + +- Adversaries may exploit software vulnerabilities of the application in an attempt to elevate privileges [7, T1068] +- Adversaries may implant application images with malicious code to establish persistence after gaining access to an environment [7, T1525]. +- Adversaries may deploy fake VNFs to collect information from the network [8, FGT5013] + +The following threats from [1] are applicable to Op-3: + +- T-O-RAN-07: An attacker compromises O-RAN monitoring mechanisms and log files integrity and availability + +#### 5.4.3.3 Potential security requirements + +To detect these threats, the following application life cycle events are recommended for security logging. This list of events may be used to develop security analytics that have the potential to detect anomalous behavior. The specific development of analytics and the definition of anomalous behavior depend on the operational environment: + +- Cryptographic hash of application package +- Onboarding of application packages +- Instantiation of application packages +- Creation of app IDs (for x/rApps) +- Changes to application configuration +- Updates to applications (REQ-SEC-ALM-PKG-14) +- Creation, modification, or deletion of identities; and transactions executed by users in applications. +- Application resource usage (disk space, CPU load) +- Decommissioning of applications +- Application API calls + +### 5.4.4 Key Issue Op-4: Secure Decommissioning of Applications + +#### 5.4.4.1 General description + +The decommissioning process for applications is an important part of the lifecycle management. During application operation, an application may perform operations on data, use resources and access secrets. The proper termination of an application can prevent excessive resource usage, accidental deletion of pertinent data (application data, cryptographic keys, etc.), and misallocation to a malicious application by a malicious actor. The removal of trust relationships associated with the application is critical in order to prevent accidental exposure to attacker. + +#### 5.4.4.2 Security threats + +The following threat(s) are applicable to Op-4: + +- T-VM-C-06: Failed or incomplete VNF/CNF termination or releasing of resources + +In addition, failure to revoke or remove credentials or other trust artifacts associated with the application could leave an exposure for an attacker to gain access. [29] + +#### 5.4.4.3 Potential security requirements + +The following prospective requirements may help mitigate key issue Op-4: + +- Identification of the replacement application prior to decommissioning of an application. +- Proper documentation of decommissioning. +- Preserving worthwhile legacy data related to the decommissioned application. +- Adherence to organization's legal guidelines. +- Deactivation of credentials +- Deactivation of permissions, accesses and rights +- Removal of all rules/roles/groups for application in existing security infrastructure +- Removal of application from allowlists +- Adding the application to the denylist in security and network monitoring tools +- Removal of relevant configuration data [31] + +### 5.4.5 Key Issue Op-5: Exploitation of Application Vulnerabilities + +#### 5.4.5.1 General description + +Vulnerabilities in an application can be exploited by a malicious actor to disrupt network service, degrade network performance, extract sensitive information, alter data, etc. + +#### 5.4.5.2 Security threats + +The following threats from [1] are applicable to Op-5: + +- T-O-RAN-01: An attacker exploits insecure designs or lack of adoption in O-RAN components +- T-xApp-01: An attacker exploits xApp vulnerabilities and misconfigurations +- T-rApp-02: An attacker exploits rApp vulnerabilities + +#### 5.4.5.3 Potential security requirements + +The following security requirements from [2] involving testing, discovery, and identification of vulnerabilities are proposed to assist in the mitigation of this key issue involving the exploitation of application vulnerabilities. + +- REQ-SEC-ALM-PKG-1 +- REQ-SEC-SYS-1 + +### 5.4.6 Key Issue Op-6: PNF Software Lifecycle Security + +#### 5.4.6.1 General description + +PNFs may include software packages that will also require lifecycle management events, including updates. Updates to PNF software could be used to inject malicious code to compromise the PNF in order to launch reverse attacks and other attacks against VNFs/CNFs. In addition, failure to implement updates that affect security of the system may result in exploitation of the vulnerabilities addressed in the updates to gain access into the system. + +This work item may propose general abstract security requirements for PNF lifecycle management; however, the PNF vendor would ultimately be responsible for PNF software management and its security. + +#### 5.4.6.2 Security threats + +The following threats from [1] are applicable to Op-6: + +- T-PNF-01: An attacker compromises a PNF to launch reverse attacks and other attacks against VNFs/CNFs + +#### 5.4.6.3 Potential security requirements + +Although general security recommendations may be proposed for PNF Software in this report, vendors are ultimately responsible for the security of their products. + +- PNF Software packages should be protected in terms of integrity and authenticity. + +### 5.4.7 Key Issue Op-7: Application Misconfiguration + +#### 5.4.7.1 General description + +Security misconfigurations can exist in an application which can provide an attacker an exploit that they can use to disrupt network service, degrade network performance, extract sensitive information, alter data, etc. These misconfigurations could include improperly configured application permissions and accesses, unnecessary open ports, and unused protocols enabled. + +#### 5.4.7.2 Security threats + +The following threats from [1] are applicable to Op-7: + +- T-O-RAN-02: An attacker exploits misconfigured or poorly configured O-RAN components +- T-rApp-03: An attacker exploits rApps misconfiguration +- T-xApp-01: An attacker exploits xApps vulnerabilities and misconfiguration + +#### 5.4.7.3 Potential security requirements + +REQ-SEC-ALM-PKG-1 from [2] may help in mitigating application misconfiguration, and additional security controls on configuration validation and maintaining up-to-date applications may be recommended. + +### 5.4.8 Key Issue Op-8: Secure Deletion of Sensitive Data + +#### 5.4.8.1 General description + +If data from a terminated application or any application that has released resources are not erased securely, a malicious application can access that data. + +#### 5.4.8.2 Security threats + +The following threat(s) are applicable to Op-8: + +- T-VM-C-06: Failed or incomplete VNF/CNF termination or releasing of resources + +#### 5.4.8.3 Potential security requirements + +The following prospective requirements may help mitigate key issue Op-8: + +- Availability of methods for secure deletion of data. +- Availability of methods for overwriting data with various sensitivity levels. + +# 6 Potential Solutions + +## 6.1 Solution #1: Application Package Authenticity and Integrity + +### 6.1.1 Introduction + +The WG11 Security Requirements and Controls Specifications [2] contains a set of requirements and security control(s) pertaining to authentication and integrity-checking of the Application package that help ensure the package has not been tampered with or damaged in transit and that the package does indeed come from the Solution Provider. The set of requirements and security controls from [2] provide a baseline level of security for Application packages. + +ETSI GS NFV-SEC 021 [26] can provide further information about the application package signing/verification procedure during onboarding and instantiation described in the Solution details below. + +### 6.1.2 Solution details + +Figure 6.1-1 provides an overview of requirements from [2] that help provide integrity and authentication to the Application package throughout its lifecycle. + +During the development phase: + +- The Application Provider signs the Application package which minimally includes the image, signing certificate, and Application Provider's signature(s). +- NOTE: Before the onboarding of application, the SMO should contain a pre-installed Root CA certificate for verifying the application integrity and authenticity. + +During the onboarding phase: + +- After the Application package is sent to the Service Provider, the Service Provider verifies the Application package artifacts and re-signs the package before it is onboarded to the catalogue. + - Signing of the Application package by the Service Provider prior to its onboarding is required for the following reasons: + - For checking the Application Provider signature during the application instantiation, it is not needed that the O-Cloud Platform contact the Application Provider outside of the Service Provider's security domain. + - It gives the Service Provider the opportunity and means to authorize Application packages for deployment on its network (e.g., avoid an Application package intended for one Service Provider with a valid Application Provider certificate being loaded by an attacker into another Service Provider's network). + - Furthermore, some Service Providers might wish to undertake additional security validation of the Application package during the onboarding process and Service Provider signing could be used to certify the application as authorized to onboard into the Service Provider's network. + +During the operation phase: + +- During application instantiation, the Application package is authenticated and verified by the O-Cloud Platform using signatures from Service Provider first and then the Application Provider. + +![Sequence diagram showing Application package authenticity and integrity protection across Development, Onboarding, and Deployment phases.](7389a894e5cf6aea4e1300a28dbc96e2_img.jpg) + +The diagram illustrates the process of application package authenticity and integrity protection across three phases: Development, Onboarding, and Deployment. The participants involved are the Application Provider, Service Provider/SMO, Catalogue, Run-Time Library, and O-Cloud Platform. + +- Development Phase:** + - The Application Provider creates an "App package with application image, signing X.509v3 certificate, signature of Application Provider." + - 1 Sign:** The Application Provider signs the package and supporting artifacts. +- Onboarding Phase:** + - 2 Signed package sent:** The signed package is sent from the Application Provider to the Service Provider/SMO. + - 3 Verify:** The Service Provider/SMO verifies the App package and all App package artifacts using the Application Provider signature. + - 4 Re-sign:** The Service Provider/SMO signs a hash value with its private key. + - 5 Onboarded:** The Service Provider/SMO onboards the package. The onboarded package contains the App package, certificate(s), and signature(s). + - 6 Publication:** The onboarded package is published to the Catalogue. +- Deployment Phase:** + - 7 Instantiation:** The O-Cloud Platform instantiates the application. The app is authenticated using signatures from both the Application Provider and the Service Provider, and the integrity of the package is verified. + +Sequence diagram showing Application package authenticity and integrity protection across Development, Onboarding, and Deployment phases. + +Figure 6.1-1 Application package authenticity and integrity protection + +## 6.2 Solution #2: Secure Update of Applications + +### 6.2.1 Introduction + +During operation, an application may need to update to a newer version to modify its features or address security. As stated in Solution #1, Application package authenticity and integrity, existing requirements in [2] relating to integrity and authentication of an Application package help provide a baseline level of application security that can be also applied to their updates. + +### 6.2.2 Solution details + +According to WG10 OAM Architecture [4], the update process consists of terminating the older version of the application and deploying the newer version of the application, as applications are atomic. This solution proposes that the deployment of the newest version of the application will follow the standard process of the onboarding of any application, which is subject to authenticity and integrity controls. Figure 6.2-1 below is tailored to application updates and depicts the set of requirements from [2] that are proposed to help secure the updating of applications in O-RAN. + +![Sequence diagram illustrating Application update authenticity and integrity protection across five entities: Application Provider, Service Provider/SMO, Catalogue, Run-Time Library, and O-Cloud Platform. The process is divided into three phases: Update Development, Update Onboarding, and Update Deployment. In Update Development, the Application Provider signs the app package (1 Sign). In Update Onboarding, the signed package is sent (2 Signed package sent), verified by the SMO (3 Verify), re-signed by the SMO (4 Re-sign), and onboarded (5 Onboarded). The onboarded package is then published (6 Publication). In Update Deployment, the app update is instantiated (7 Instantiation) and authenticated by the O-Cloud Platform, which also performs decommissioning of older apps (8 Decommissioning of older App).](4228488bd5fd7673a8b2a838311a6847_img.jpg) + +``` + +sequenceDiagram + participant AP as Application Provider + participant SMO as Service Provider/SMO + participant C as Catalogue + participant RTL as Run-Time Library + participant OCP as O-Cloud Platform + + Note over AP: App package with update application image, signing X.509v3 certificate, signature of Application Provider. + AP->>AP: 1 Sign + Note over AP: Package and supporting artifacts signed by the Application Provider. + Note over C: Update Development + AP->>SMO: 2 Signed package sent + Note over SMO: 3 Verify + Note over SMO: SMO verifies update App package and all App package artifacts using Application Provider signature + Note over SMO: 4 Re-sign + Note over SMO: Hash value signed with private key of Service Provider + Note over SMO: 5 Onboarded + Note over C: Onboarded App package contains App package update, certificate(s) and signature(s) + Note over C: 6 Publication + Note over RTL: Update Onboarding + Note over RTL: 7 Instantiation + Note over OCP: App update is authenticated using signatures from both Application Provider and Service Provider, and integrity of package is verified. + Note over OCP: 8 Decommissioning of older App + OCP->>OCP: + +``` + +Sequence diagram illustrating Application update authenticity and integrity protection across five entities: Application Provider, Service Provider/SMO, Catalogue, Run-Time Library, and O-Cloud Platform. The process is divided into three phases: Update Development, Update Onboarding, and Update Deployment. In Update Development, the Application Provider signs the app package (1 Sign). In Update Onboarding, the signed package is sent (2 Signed package sent), verified by the SMO (3 Verify), re-signed by the SMO (4 Re-sign), and onboarded (5 Onboarded). The onboarded package is then published (6 Publication). In Update Deployment, the app update is instantiated (7 Instantiation) and authenticated by the O-Cloud Platform, which also performs decommissioning of older apps (8 Decommissioning of older App). + +Figure 6.2-1 Application update authenticity and integrity protection + +## 6.3 Solution #3 Application Security Descriptor + +### 6.3.1 Introduction + +O-RAN WG10 describes a high-level composition of the Application Package which includes the security descriptor focusing on privileges, roles, users, and certificates as illustrated in the following figure. In order to completely define the characteristics of a security descriptor of an O-RAN application, this clause proposes an extension to the preliminary O-RAN WG10 security descriptor by capturing and analysing additional security attributes applicable to O-RAN application. These security attributes should be packaged with the application image, forming an Application package. + +It is expected that information in this clause may face changes and adjustments to accommodate unforeseen needs that may arise from O-RAN WG10. + +![Figure 6.3-1: Application Package High Level Model from WG10 OAM [4]. This is a hierarchical diagram showing the structure of an application package. At the top is 'AppPackage'. It has three children: 'DeploymentDescriptor', 'MLModelDescriptor', and 'ManagementDescriptor'. 'DeploymentDescriptor' has a child 'DeploymentItem'. 'MLModelDescriptor' has a child 'ComponentDescriptor'. 'ManagementDescriptor' has children 'ComponentDescriptor', 'SecurityDescriptor', 'AlarmDictionary', 'ConfigurationModel', 'AccountingDictionary', and 'PerformanceDictionary'. 'DeploymentItem' has children 'CloudNativeDescriptorFile' and 'ExecutableImage'. 'ComponentDescriptor' has children 'RTEDescriptor' and 'SecurityDescriptor'. 'SecurityDescriptor' is circled in red. Relationships are labeled as 'Has' or 'May Have'.](7ef350d1705d5873a21229206ed5a152_img.jpg) + +Figure 6.3-1: Application Package High Level Model from WG10 OAM [4]. This is a hierarchical diagram showing the structure of an application package. At the top is 'AppPackage'. It has three children: 'DeploymentDescriptor', 'MLModelDescriptor', and 'ManagementDescriptor'. 'DeploymentDescriptor' has a child 'DeploymentItem'. 'MLModelDescriptor' has a child 'ComponentDescriptor'. 'ManagementDescriptor' has children 'ComponentDescriptor', 'SecurityDescriptor', 'AlarmDictionary', 'ConfigurationModel', 'AccountingDictionary', and 'PerformanceDictionary'. 'DeploymentItem' has children 'CloudNativeDescriptorFile' and 'ExecutableImage'. 'ComponentDescriptor' has children 'RTEDescriptor' and 'SecurityDescriptor'. 'SecurityDescriptor' is circled in red. Relationships are labeled as 'Has' or 'May Have'. + +Figure 6.3-1: Application Package High Level Model from WG10 OAM [4] + +The following figure shows a basic representation of the structure of an application. An application is composed of VMs/CNs that are interconnected. In the definition of this interconnection, the expected security policies for the traffic and communication need to be provided. Further, an application exposes services to external applications or users, in the form of APIs or dashboards. An application should support the definition of Service Availability Level (SAL) with requirements on scaling and migration over the set of metrics exposed by an application for ensuring availability and continuity of the provided services. + +![Figure 6.3-2: Application interconnection. This diagram shows two 'App/VNF' blocks connected. Each block contains a 'VM/CN' and a 'CP' (Connection Point). The 'CP' of the first block is connected to the 'CP' of the second block via an internal link. The 'CP' of the first block is also connected to an 'ECP' (External Connection Point) via an external link. The 'ECP' of the first block is connected to the 'ECP' of the second block via an external link. A legend below the diagram defines CP as internal link and ECP as external link.](0d724ff68bd941c2d91d7239a383c427_img.jpg) + +Figure 6.3-2: Application interconnection. This diagram shows two 'App/VNF' blocks connected. Each block contains a 'VM/CN' and a 'CP' (Connection Point). The 'CP' of the first block is connected to the 'CP' of the second block via an internal link. The 'CP' of the first block is also connected to an 'ECP' (External Connection Point) via an external link. The 'ECP' of the first block is connected to the 'ECP' of the second block via an external link. A legend below the diagram defines CP as internal link and ECP as external link. + +Figure 6.3-2: Application interconnection + +### 6.3.2 Solution details + +ETSI GS NFV-IFA 011 [11] specifies the following requirements applicable to application descriptor attributes: + +- **VNF\_PACK.META.025:** The VNFD shall support a description of the security rules to filter the ingress/egress packets related to the VNF. + - The filtering rules include, but are not limited to, the packet direction, TCP/UDP port range, IP protocol, etc. +- **VNF\_PACK.META.026:** The VNFD shall support associating the security rules to the relevant VNF connection points. +- **VNF\_PACK.META.017:** The VNFD shall support a description of Service Availability Level (SAL) requirements for virtual resources on the underlying NFVI. + +For fulfilling the ETSI security requirement on application descriptors, the following two categories of attributes are proposed: + +1. Security group rules descriptor: used by the O-Cloud platform to enforce network security between Apps/VNFs by disallowing sniffing of network traffic. +2. Service Availability Level (SAL) requirements descriptor: used by the SMO to monitor and guarantee the compliance of Apps/VNFs and O-Cloud with the defined SALs in the descriptor. Such monitoring activities + +include the monitoring of the status of an App/VNF, resource provisioning, and detecting resource overloading. + +#### 6.3.2.1 Security group rules descriptor + +**Related ETSI requirement:** VNF\_PACK.META.025, VNF\_PACK.META.026 + +This security descriptor contains the security group rules. It is used by the O-Cloud platform for specifying the matching criteria for the ingress and/or egress traffic to/from visited connection points as defined in ETSI GS NFV-IFA 011 [11]. These rules aim to enforce security for applications at the Ethernet and IP layers by disallowing sniffing of network traffic. They cover the following elements: + +- The direction of traffic in which the security group rule is applied. The direction of ‘ingress’ or ‘egress’ is specified against the associated CP/ECP, i.e., ‘ingress’ means the packets entering a CP/ECP (response), while ‘egress’ means the packets sent out of a CP/ECP (request). +- Protocol to filter the Ethernet layer. Permitted values include IPV4 and IPV6. +- Protocol to filter the IP layer. Permitted values include any protocol defined in the IANA protocol registry [12], e.g., TCP, UDP, ICMP, etc. +- Start of port range (inclusive). It indicates minimum port number in the range that is matched by the security group rule. If a value is provided at design-time, this value may be overridden at run-time based on other deployment requirements or constraints. It is required if protocol is ‘tcp’ or ‘udp’: Defaults to 0. +- End of port range (inclusive). It indicates maximum port number in the range that is matched by the security group rule. If a value is provided at design-time, this value may be overridden at run-time based on other deployment requirements or constraints. It is required if protocol is ‘tcp’ or ‘udp’: Defaults to 65535. + +Each of the elements outlined here above are translated to security group rules attributes and summarized in this table. + +**Table 6.3-1: Security group rules descriptor** + +| Attribute | Type | Description | +|------------------------------------|---------|--------------------------------------------------------------------------------------------------------------------------------------------| +| Security_group_rule.id | Integer | id of the Security Group Rule | +| Security_group_rule.description | String | Description of Security Group Rule | +| Security_group_rule.direction | String | Direction of the Security Group Rule. Allowed values:
  • • Ingress
  • • Egress
| +| Security_group_rule.ether_type | String | Type of the Security Group Rule. Allowed values:
  • • IPV4
  • • IPV6
| +| Security_group_rule.protocol | String | Protocol of the Security Group Rule. Allowed values:
  • • TCP
  • • UDP
  • • Any
| +| Security_group_rule.port_range_min | Integer | Minimum port number of the range applicable to the Security Group Rule. | +| Security_group_rule.port_range_max | Integer | Maximum port number of the range applicable to the Security Group Rule. | + +Here below is an example of an application descriptor template structure and its security group rules attributes based on TOSCA standards and written in YAML [13]. It should be on-boarded in the Application package. + +``` +tosca.policies.nfv.SecurityGroupRule: + derived_from: toska.policies.Root + description: The SecurityGroupRule type is a policy type specified the matching criteria for +the ingress and/or egress traffic to/from visited connection points as defined in ETSI GS NFV- +IFA 011 [11]. + properties: + description: + type: string + description: Human readable description of the security group rule. + required: false + direction: + type: string + description: The direction in which the security group rule is applied. The direction of +'ingress' or 'egress' is specified against the associated CP. I.e., 'ingress' means the +packets entering a CP, while 'egress' means the packets sent out of a CP. + required: false + constraints: + - valid_values: [ ingress, egress ] + default: ingress + ether_type: + type: string + description: Indicates the protocol carried over the Ethernet layer. + required: false + constraints: + - valid_values: [ ipv4, ipv6 ] + default: ipv4 + protocol: + type: string + description: Indicates the protocol carried over the IP layer. Permitted values include +any protocol defined in the IANA protocol registry, e.g. TCP, UDP, ICMP, etc. + required: false + constraints: + - valid_values: [ hopopt, icmp, igmp, ggp, ipv4, st, tcp, cbt, egp, igp, bbn rcc mon, +nvp ii, pup, argus, emcon, xnet, chaos, udp, mux, dcn meas, hmp, prm, xns idp, trunk 1, +trunk_2, leaf_1, leaf_2, rdp, irtp, iso_tp4, netblt, mfe_nsp, merit_inp, dccp, 3pc, idpr, xtp, +ddp, idpr_cmt, tp++, il, ipv6, sdrp, ipv6_route, ipv6_frag, idrp, rsvp, gre, dsr, bna, esp, +ah, i_nls, swipe, nar, mobile, tlsp, skip, ipv6_icmp, ipv6_no_nxt, ipv6_opts, cftp, +sat_expak, kryptolan, rvd, ippc, sat_mon, visa, ipcv, cpnx, cphb, wsn, pvp, br_sat_mon, +sun_nd, wb_mon, wb_expak, iso_ip, vmtp, secure_vmtp, vines, ttp, iptm, nsfnet_igp, dgp, tcf, +eigrp, ospfig, sprite_rpc, larp, mtp, ax.25, ipip, micp, scc_sp, etherip, encap, gmtp, ifmp, +pnni, pim, aris, scps, qnx, a/n, ip_comp, snp, compaq_peer, ipx_in_ip, vrrp, pgm, l2tp, ddx, +iatp, stp, srp, uti, sm, ptp, isis, fire, crtp, crudp, sscpmce, iplt, sps, pipe, sctp, +fc, rsvp_e2e_ignore, mobility, udp_lite, mpls_in_ip, manet, hip, shim6, wesp, rohc ] + default: tcp + port_range_min: + type: integer + description: Indicates minimum port number in the range that is matched by the security +group rule. If a value is provided at design-time, this value may be overridden at run-time +based on other deployment requirements or constraints. + required: false + constraints: + - greater_or_equal: 0 + - less_or_equal: 65535 + default: 0 + port_range_max: + type: integer + description: Indicates maximum port number in the range that is matched by the security +group rule. If a value is provided at design-time, this value may be overridden at run-time +based on other deployment requirements or constraints. + required: false + constraints: + - greater_or_equal: 0 + - less_or_equal: 65535 + default: 65535 + targets: [ toska.nodes.nfv.VduCp, toska.nodes.nfv.VnfExtCp ] +``` + +#### 6.3.2.2 Service Availability Level (SAL) requirements descriptor + +Editor's Note: It may be necessary to liaise very closely with WG6 and WG10 on the SAL descriptor to ensure that the proposed descriptor is in line with the descriptor under progress by WG6/WG10. + +##### Related ETSI requirement: VNF\_PACK.META.017 + +An application should support the definition of SALs with requirements over the set of metrics exposed by the applications, which can be used by the SMO to trigger resource scaling or migration actions for avoiding resource overloading and application downtime. By performing these actions, the compliance with the defined SALs in the security descriptor can be guaranteed. + +This security descriptor is used by the SMO for monitoring the status of an App/VNF to provide correct service availability and continuity. The monitoring should not only check if an application is “up and running”, but also it should provide resource provisioning and detect resource overloading. This requires two efforts from application providers. Firstly, they must expose a way to extract the real-time value of their SLI (Service Level Indicator). Secondly, they must instruct the SMO and O-Cloud on how to collect, analyse, and react whenever an SAL is being breached. While the first effort is about creating an HTTP endpoint, the second is to provide an application descriptor that describes: HTTP endpoints, expression to evaluate every SAL, and the instructions to follow when a SAL is being breached (e.g., migrate service, change the number of resources allocated, etc.). + +The SAL requirements descriptor should cover the following elements: + +- Support of SAL requirements over the set of metrics exposed by the VNFs, which can be used by SMO (NFO, FOCOM) and O-Cloud to trigger scaling or migration actions. + - Required resources (CPU, Memory, Storage, ...): Namespace quotas, required (initial deployment) or Limit (runtime/scaling) Quota +- Monitoring the status of an application is crucial to provide correct service availability and continuity. +- Descriptor for SMO (NFO, FOCOM) on how to collect, analyse, and react whenever a SAL requirement is being breached. It should describe, among others: + - Expression to evaluate every requirement, and + - Instructions to follow when a requirement is being breached (e.g., migrate service, change the number of resources allocated, etc.). + +The proposed SAL requirements descriptor is described in the following table: + +**Table 6.3-2: SAL requirements descriptor** + +| Attribute | Type | Description | +|--------------------|---------|-----------------------------------------------------------------------------------------------------------------------------| +| SAL | Object | Service Availability Level | +| SAL.name | String | Name of the SAL | +| SAL.metric | String | Reference to the metric when presented as already aggregated. Either the field metric or expression exist in an SAL object. | +| SAL.threshold | Integer | If the value of the SAL is GREATER than or LOWER than this value, it constitutes a violation of the SAL | +| SAL.threshold_type | String | Type of the threshold. Allowed values are GT (Greater Than) or LT (Lower Than) | +| SAL.action | Object | Action type object describing the action to be taken if SAL is violated | + +| | | | +|-------------------|---------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| SAL.check | Integer | Every number of seconds that this SAL will be checked, the SAL.threshold must be crossed in order to consider a violation of SAL | +| Action | Object | Action container object | +| Action.target_ref | String | Reference to the target application on which to perform an action. | +| Action.step | String | Action to be executed every time the SAL is violated. Allowed values are:
  • • TRIGGER_SCALE_UP
  • • TRIGGER_SCALE_IN
  • • TRIGGER_MIGRATION
| + +## 6.4 Solution #4: Secure Logging and Monitoring for Applications + +### 6.4.1 Introduction + +Key Issue Op-3 identified security threats that could be detected by logging application life cycle events and recommended a set of application life cycle events for security logging. These events were mapped to Key Issue SLC#1 Logging Security Related Activity and Events in the WG11 technical report “Study on Security Log Management” [14] in order to ensure coverage of these events. Within that technical report, Key Issue SLC#1 was updated to account for missing application life cycle logging events. + +### 6.4.2 Solution details + +Table 6.4-1 shows the mapping of specific application LCM events to the categories described in the updated Secure Log Management Key Issue SLC#1 to show coverage of the application events. The application events recommended to be logged are fully covered by the events listed in the Secure Log Management technical report [14] and are planned to be included in subsequent solutions and requirements from the Secure Log Management Work Item. + +**Table 6.4-1: Application LCM Logging Event Coverage** + +| AppLCMSec TR KI Op-3
Application LCM Event | Security Log Management TR KI SLC#1
Security Logging event | +|-------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------| +| Cryptographic hash of application package | 5d: Cryptographic operations | +| Onboarding of application packages | 2c: Image registry events, addition | +| Instantiation of application packages | 2a: Lifecycle events, service creation | +| Creation of app IDs (for x/rApps) | 3f: Creation of identities | +| Changes to application configuration | 2g: Change notifications | +| Updates to applications | 2f: Maintenance activity undertaken
2g: Change notifications | +| Creation, modification, or deletion of identities; and transactions executed by users in applications | 3f: Creation, modification, or deletion of identities; and transactions executed by users in applications. | + +| | | +|---------------------------------------------------|----------------------------------------| +| Application resource usage (disk space, CPU load) | 1c: Resource usage | +| Decommissioning of applications | 2a: Lifecycle events, service deletion | +| Application API calls | 2d: API calls | + +## 6.5 Solution #5: Software Bill of Materials Requirement for Applications + +### 6.5.1 Introduction + +The requirements in Clause 6 of the WG11 Security Requirements and Controls Specifications [2] for Software Bill of Materials for O-RAN were reviewed to ensure coverage for application packages. + +### 6.5.2 Solution details + +It was determined that the initial requirement REQ-SBOM-001 covers O-RAN applications, and the subsequent requirements REQ-SBOM-002 through REQ-SBOM-011 cover the necessary fields, depth, format, and signature and encryption requirements for SBOMs for applications. + +**REQ-SBOM-001:** The O-RAN vendor should provide the SBOM with every O-RAN software delivery, including patches, to the network operator. + +This solution recommends changing REQ-SBOM-001 to be a mandatory requirement in the WG11 Security Requirements and Controls Specifications [2], instead of optional, to comply with current supply chain security best practices. + +## 6.6 Solution #6: Recommendations for Vulnerability Scanning + +### 6.6.1 Introduction + +The goal of this solution is to provide application vendors with recommendations on scanning their software throughout the software development lifecycle for vulnerabilities. This scanning can take the form of static application security testing (SAST), software composition analysis (SCA), or dynamic application security testing (DAST). + +Beyond the requirements listed below which are already in the O-RAN specifications, these recommendations will stay in the technical report as best practices. The details of the vulnerability scanning and specific tools are left up to vendor implementation and out of scope of normative O-RAN security specifications. + +This solution is part of mitigating Key Issue Op-5: Exploitation of Application Vulnerabilities. Discovery and identification of application vulnerabilities will allow for vendors to mitigate those vulnerabilities before integrating the application into the O-RAN environment. + +### 6.6.2 Solution details + +Performing vulnerability scanning is an important part of secure software development. NIST [15], [16] and ESF [17] recognize that early and frequent vulnerability scanning is a key aspect of software security assurance, and automation can allow this scanning to be performed more efficiently and repeatedly. + +NISTIR 8397 [15] provides a guideline for minimum standard techniques for software developers to use to verify their software. These minimum recommendations for best practices should also be used for O-RAN application developers. Additional references, alternatives, and example tools are provided in [15] for more information. + +NIST SP 800-53 [16] provides more details on application security testing, including Interactive Application Security Testing (IAST), Dynamic Application Security Testing (DAST), and Runtime Application Self-Protection (RASP) tools. + +These general recommendations are comprised in REC-SEC-ALM-PKG-1 in the O-RAN Security Requirements and Controls Specifications [2]: + +**REQ-SEC-ALM-PKG-1:** The Application package shall be certified by the Application Provider. + +EXAMPLE: Software testing suites for certification include vulnerability scanning, static and dynamic testing, and penetration testing. Refer to Annex C clause C.2.1 for additional information. + +Additionally, Annex C of [2] provides non-normative guidance on implementing this requirement during development, on-boarding, and runtime. It details the type of testing, responsible party for the testing, and rationale for the testing. + +REQ-SEC-ALM-PKG-1 and Annex C of [2] show the requirement for O-RAN application vulnerability scanning in the specifications, and the additional industry resources and standards provided above give more details for application vendors to follow the industry best practices for vulnerability scanning during application development. + +## 6.7 Solution #7: Recommendations for Addressing Application Vulnerabilities + +### 6.7.1 Introduction + +The goal of this solution is to provide application vendors with recommendations on addressing security vulnerabilities in their software. + +Beyond any requirements listed below which are already in the O-RAN specifications, these recommendations will stay in this technical report as best practices. The details of the vulnerability fixes, including exact timeframe, are left up to vendor implementation and out of scope of O-RAN specifications. + +This solution is part of mitigating Key Issue Op-5: Exploitation of Application Vulnerabilities. Timely vulnerability fixes for O-RAN applications will help prevent the exploitation of application vulnerabilities and therefore reduce overall risk for the O-RAN system. + +### 6.7.2 Solution details + +O-RAN Security Requirements and Controls Specifications [2] includes REC-SEC-ALM-PKG-1 which is documented in Solution #6. It requires the Application provider to eliminate any flaws and defects found during testing before delivery to the Service Provider and then provide the testing results. + +In addition to this general requirement, several resources external to O-RAN provide guidelines and best practices for addressing vulnerabilities in software or applications. These resources should be used by O-RAN application vendors to address vulnerabilities in their software to increase the security of the O-RAN system. + +Linux Foundation's OpenSSF [18], [19] provides guidelines and badging criteria that help ensure open-source software is developed following their best practices. This includes secure software development practices, bug and vulnerability reporting processes, automated testing, use of basic good cryptographic practices, fixing publicly known vulnerabilities, and code analysis. + +ESF's Software Supply Chain for Suppliers [20] highlights several of these practices as well, including vulnerability reporting and the subsequent response process, verification of third-party software, and code reviews for security and continuous software security improvement. Many of these same practices are included in NIST 800-53 [16] and NISTIR 8397 [15]. + +Center for Internet Security (CIS) Critical Security Controls list [21] includes Control 7 on Continuous Vulnerability Management and Control 16 on Application Software Security, with the focus on discovering vulnerabilities and resolving or remediating vulnerabilities on a monthly or more frequent basis in order to reduce risk. + +To summarize these recommendations: + +- Recommendations for vendor verification of third-party packages in their code: + - Application providers should perform continuous verification of third-party binaries via binary scanning and software composition analysis. + - Application providers should monitor known vulnerabilities in their application's direct and indirect dependencies and keep dependencies reasonably up to date. + - Application providers should verify third party applications are compliant with relevant security requirements. +- Recommendations for vendor fixes of security issues in their code: + - Application providers should fix all publicly known vulnerabilities in a reasonable timeframe and fix all critical vulnerabilities in a timely manner after they are confirmed. + - Application providers should have a vulnerability report process documented to notify the community of vulnerabilities in their application. + +## 6.8 Solution #8: PNF Software Lifecycle Security Recommendations + +### 6.8.1 Introduction + +PNFs such as O-RUs and O-DUs may include software packages that will be downloaded, installed, activated, and updated. These PNF software packages have similar lifecycle events as outlined for applications in this technical report. It is important that security is addressed in these lifecycle events for the reasons mentioned in Key Issue Op-6: PNF Software Lifecycle Security. + +This solution outlines general recommendations for security aspects during these software lifecycle events and maps to the security mechanisms and processes already in place in O-RAN specifications. It is beyond the scope of this work item and technical report to consider PNF registration and certificate management for PNFs. In addition, it is noted that PNF software format is vendor implementation specific and not standardized in O-RAN [23]. + +Additional information for security of O-RU software packages is listed in the WG4 M-Plane specification [22], while information for O-DU software package security is listed in WG10 O1 Interface specification [23]. + +### 6.8.2 Solution details + +Recommended security requirements and mechanisms are listed by PNF software lifecycle event in Table 6.8-1. These security mechanisms are derived from industry recommendations for strong security controls. Specifically, the CIS Critical Security Controls [21] provides information on access control management, protecting data and data access, and controlling configuration of software assets. NIST SP 800-53 [16] provides details on access control and authorization, malicious code protection, software integrity, failover capability, and component authenticity. + +**Table 6.8-1: Recommended security mechanisms** + +| Software Lifecycle Event | Recommended Security Mechanisms for PNF software package | +|---------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------| +| PNF Software Download & Install |
  • • Integrity check
  • • Authentication
  • • Secure file transfer
| +| PNF Software Activation |
  • • Authorization
| +| PNF Software Update |
  • • Integrity check
  • • Authentication
  • • Secure transport
  • • Authorization
| + +| | | +|--|-------------------------------------------------------------------------------------------------------------------| +| |
  • Ability to restore to previous secure state if errors in update
| +|--|-------------------------------------------------------------------------------------------------------------------| + +These security mechanisms are evaluated to help mitigate the threats listed in Key Issue Op-6. Additional vulnerability and SBOM analysis by the PNF software vendor is recommended to detect malware or potential vulnerabilities and protect against introduction of malicious code to the PNF. + +Many of these security aspects are covered in technical specifications from WG4 and WG10, specifically Clause 8 Software Management from WG4 M-plane Specification [22] and Clause 2.8 PNF Software Management Services from WG10 O1 Interface Specification [23]. Currently, WG10 O1 specification covers O1 compliant nodes, which includes O-DU but not O-RU. WG4 M-plane specification covers O-RU. Below, software management security controls are summarized from these specifications per the lifecycle event. Specifics of the security mechanisms can be found at the referenced clause of the specifications. + +#### Security mechanisms currently in O-RAN specifications: + +- PNF Software Download & Install: + - NOTE: Software Download for O-DU includes installation of the software [23]. For O-RU, software download and install are separate processes [22]. + +| | O-RU | O-DU | +|----------------------|---------------------------------------------------------------------------------|--------------------------------------------------------------------| +| Integrity check | May be supported at download and during software install [22, Clause 8.5 & 8.6] | Must be supported on downloaded software [23, REQ-SWD-FUN-5]. | +| Authentication | Must be supported for software download [22, Clause 8.5] | Must be supported for software download [23, Clause 2.8.3] | +| Secure file transfer | Must be supported for software file download to the O-RU [22, Clause 8.5] | Must be supported for software package download [23, Clause 2.8.3] | + +- PNF Software Activate: + +| | O-RU | O-DU | +|---------------|-------------------------------------------------------|-----------------------------------------------------------------------------| +| Authorization | Authorization check is not supported [22, Clause 8.7] | Must be supported upon activation request [23, Clause 2.8.5, REQ-SWA-FUN-1] | + +- PNF Software Update: + - The update process outlined in the WG4 and WG10 specifications follows the same process of the lifecycle events above: inventory, download, install, and activate. + - NOTE: A “software slot” is an independent storage location for a single software build. Only one software slot can be active at any time. [22] + +| | O-RU | O-DU | +|----------------------|---------------------------------------------------------------------------------|--------------------------------------------------------------------| +| Integrity check | May be supported at software download and during install [22, Clause 8.5 & 8.6] | Must be supported on downloaded software [23, REQ-SWD-FUN-5]. | +| Authentication | Must be supported for software download [22, Clause 8.5] | Must be supported for software download [23, Clause 2.8.3] | +| Secure file transfer | Must be supported for software file download to the O-RU [22, Clause 8.5] | Must be supported for software package download [23, Clause 2.8.3] | + +| | | | +|-----------------------------------------------------------------|-------------------------------------------------------|-----------------------------------------------------------------------------| +| Authorization | Authorization check is not supported [22, Clause 8.7] | Must be supported upon activation request [23, Clause 2.8.5, REQ-SWA-FUN-1] | +| Ability to restore to previous secure state if errors in update | Supported [22, Clause 8.8] | Supported [23, Clause 2.8.5, REQ-SWA-FUN-8 and 9] | + +#### Comparison of specifications to recommendations and additional recommendations: + +As can be seen by the above mapping of recommended security mechanisms to the specifications, the current WG4 and WG10 specifications for the O-RU and O-DU offer support for many of the recommended security requirements and controls for PNF software. PNF software management requirements are expected to be specified in a 3GPP specification from SA5 Workgroup when complete [23], so this should be reviewed again at that time. + +To further enhance the security posture, it is recommended that the PNF software package be authenticity and integrity protected. Currently, this is supported by WG10 specifications for the O-DU and optionally supported by WG4 specifications for the O-RU. + +Additional recommendations to consider include authorization prior to software activation, including during update. Authorization would ensure that software is permitted to run on the PNFs. + +## 6.9 Solution #9: Application Integrity during Operation + +### 6.9.1 Introduction + +The operation lifecycle phase of O-RAN applications presents an opportunity for actors to perform malicious activities. Key Issue Op-2 provides information about the applicable threats and potential security requirement recommendation(s) for mitigation. Detecting and preventing threats during application runtime is still an on-going research problem. Proposing security controls in the O-RAN Alliance specifications to prevent these threats presents some challenges, especially within the context of standards and normative specifications, and may not be feasible at this time. + +Defining security for ensuring application integrity during operation may be implementation and architecture specific and may not necessarily apply to all O-RAN application deployments. Many exploits to application integrity rely on the underlying architecture and mitigations are system dependent. Application integrity monitoring during operation presents some challenges which are outlined in the subsequent paragraphs. + +Monitoring application integrity during runtime requires that there is an entity that monitors the application and verifies its integrity. The monitoring entity itself needs to be protected from an adversary to ensure the monitor is not compromised by a malicious actor and that integrity verification results are unmodified. + +Another area to explore is how exactly an untampered application should look like during operation in terms of memory data. Verifying the integrity of a running application requires knowledge of the known good states of the application and what is not. Changing application data within memory may not necessarily indicate a tampered application, especially considering AI/ML applications. + +Another factor to consider is the performance impact of integrity monitoring for control loop execution times for xApps and rApps. The Near-RT RIC requires control loops from 10 milliseconds to 1s, and the Non-RT RIC control loops are specified for more than 1 second. These control loop execution times must be considered, especially for xApps, when factoring in potential negative effects on performance by monitoring for integrity on running O-RAN applications. + +### 6.9.2 Solution details + +Although there may not be any feasible normative requirements proposed to help mitigate the threats during application runtime, recommendations and already existing requirements and security controls can help with this issue: + +- Before application delivery to the service provider, security mechanisms such as scanning for vulnerabilities and dynamic and static testing of the application package may be performed for certification by the solution provider before software delivery (REC-SEC-ALM-PKG-1). + +- During onboarding, the O-RAN application also undergoes a dual signature process, featuring signing of the application package by the solution provider and service provider, that verifies the authenticity and integrity of the application package (SEC-CTL-ALM-PKG-2). +- Every O-RAN application requires the SBOM with every O-RAN software delivery (REQ-SBOM-001). Scanning of the SBOM artifacts for comparison with the Common Vulnerabilities and Exposures (CVE) database (for example, in [24]) for known vulnerabilities may enable discovery of potential known exploits for code/libraries used in the application. + +Although directly monitoring for application integrity during operation may not be feasible to specify, security measures in place already in the specifications help ensure that the application is tested for vulnerabilities, authenticity, and integrity before operation, and can lower the likelihood of exploits that affect application integrity during operation. + +## 6.10 Solution #10: Secure Decommissioning of Applications + +### 6.10.1 Introduction + +As mentioned in the description clause, the decommissioning process for applications is an important part of the lifecycle management. As such, the related literature was reviewed and various approaches to the decommissioning were closely examined [28], [29], [31]. + +### 6.10.2 Solution details + +When dealing with secure decommissioning of applications, various organizations recommend some best practices. The essence of those is captured in the following requirements: + +- A replacement application (or lack of it) should be known and available to avoid any service and performance gaps prior to decommissioning of an application. +- Any decommissioning of applications should be properly documented. +- Sometimes parts of legacy data are valuable because of historical reasons or because they are difficult to reproduce. As such, worthwhile legacy data related to the decommissioned application should be preserved. +- All trust relationships associated with the application should be removed or revoked. + +A recommendation to keep in mind is to adhere to the organization's legal guidelines for storing legacy data. + +## 6.11 Solution #11: Secure Deletion of Sensitive Data + +### 6.11.1 Introduction + +NIST instead of deletion utilizes clear and purge terminologies [30]. Clear and purge are used for sensitive and highly sensitive data, respectively. Purged data cannot be recovered with the state of art laboratory techniques, while cleared data can potentially be recovered using state of art laboratory techniques. + +Storage device technologies can be divided into magnetic and solid state devices. Magnetic Media consists of ATA hard disk drives and SCSI hard disk drives. Solid state media, on the other hand, consist of ATA solid state, SCSI solid state and NVM express devices. Some purge options are applicable at the hardware disposal time. + +### 6.11.2 Solution details + +The recommended clear/purge procedures are listed below: + +#### ATA Hard Disk Drives + +- **Clear:** at least one pass of writes with a fixed data value, such as all zeros. Multiple passes or more complex values may alternatively be used. + +- **Purge** + - Option 1: Issue cryptographic erasing command to cause all Media Encryption Keys (MEKs) to be changed. Then optionally use the block erase command (or clear procedure, if block erase is not supported) to block erase the media. + - Option 2: ATA sanitize commands + - Option 3: ATA SECURE ERASE UNIT commands + - Option 4: Degauss using an approved degausser + +#### SCSI Hard Disk Drives + +- **Clear:** at least one pass of writes with a fixed data value, such as all zeros. Multiple passes or more complex values may alternatively be used. +- **Purge** + - Option 1: Issue cryptographic erasing command to cause all MEKs to be changed. Then optionally use the block erase command (or clear procedure, if block erase is not supported) to block erase the media. + - Option 2: SCSI sanitize commands + - Option 3: Degauss using an approved degausser + +Flash memory-based storage devices are made of ATA solid state devices, SCSI solid state devices and NVM express SSDs. The recommended clear/purge procedures for each technology are provided below: + +#### ATA Solid State Devices + +- **Clear:** + - Option 1: at least one pass of writes with a fixed data value, such as all zeros. Multiple passes or more complex values may alternatively be used. + - Option 2: SECURITY ERASE UNIT command +- **Purge:** + - Option 1: Issue cryptographic erasing command to cause all MEKs to be changed. Then optionally use the block erase command (or clear procedure, if block erase is not supported) to block erase the media. + - Option 2: ATA sanitize command + +#### SCSI Solid state Devices + +- **Clear:** at least one pass of writes with a fixed data value, such as all zeros. Multiple passes or more complex values may alternatively be used. +- **Purge** + - Option 1: Issue cryptographic erasing command to cause all MEKs to be changed. Then optionally use the block erase command (or clear procedure, if block erase is not supported) to block erase the media. + - Option2: SCSI SANITIZE + +#### NVM Express Devices + +- **Clear:** at least one pass of writes with a fixed data value, such as all zeros. Multiple passes or more complex values may alternatively be used. +- **Purge** + - Option 1: Issue cryptographic erasing command to cause all MEKs to be changed. Then optionally use the block erase command (or clear procedure, if block erase is not supported) to block erase the media. + - Option 2: NVM Express Format command + +## 6.12 Solution #12: rAppID Uniqueness + +### 6.12.1 Introduction + +A unique identifier for an rApp instance within a Non-RT RIC runtime environment would help prevent the threat of collision from two rApps with the same ID. A unique ID assignment is also an important part of security logging to be able to appropriately identify applications in log files, and a unique ID can help prevent operational disruptions due to misassigning resources or services to the incorrect application. + +The Near-RT RIC Security Technical Report [33] proposes UUID v4 as described in RFC 4122 [32] as the format for xApp IDs to ensure its uniqueness. UUID v4 provides generation details to ensure uniqueness to prevent the threat of collision. UUID v4 can also be considered for the format for rAppIDs of rApp instances to help ensure each rApp + +instance may have their own unique identification. It is recommended that WG2 review and specify rAppID format to ensure uniqueness. + +### 6.12.2 Solution Details + +The following recommendations should be considered for inclusion in the O-RAN Security Requirements and Controls TS to mitigate the threats from non-unique application identifiers. + +- rAppID should be unique within the Non-RT RIC runtime environment. +- rAppIDs should be generated using strong randomization methods to resist brute force attacks. + +## 6.13 Solution #13: Secure Application Registration Procedure + +### 6.13.1 Introduction + +The registration procedure for xApps and rApps occurs after onboarding and instantiation of the application. In the registration procedure, the applications are registered to the Near-RT RIC platform or Non-RT RIC/SMO Framework respectively. In both cases, the application is authenticated before it is assigned an identifier. For more information about the application registration process, refer to WG2 R1 Use Cases [9] for rApps and WG3 RICARCH [10] for xApps. This solution proposes a common security process during xApp/rApp registration for authenticating the application, which is proposed to be defined in WG11 specifications. + +### 6.13.2 Solution Details + +Figures 6.13-1 and 6.13-2 depict the application registration procedures for rApps and xApps, respectively, with the addition of the authenticity check per WG11 specifications. The application sends a registration request message to the respective entity (Near-RT RIC or Non-RT RIC) which processes the request. The Near-RT RIC or Non-RT RIC should authenticate the application by: + +- Verifying Service Provider Signature +- Verifying integrity of application package +- Verifying certificates are not revoked + +![Sequence diagram showing the registration process for rApps. The diagram involves two main entities: 'rApp' (represented by a yellow box on the left) and 'Non-RT RIC' (represented by a blue box on the right). The 'Non-RT RIC' contains 'SME functions' at the top and bottom. A horizontal line separates the 'rApp registration' phase from the rest of the process. Step 1: 'rApp' sends a message '1 <>Registration request' to 'Non-RT RIC'. Step 2: 'Non-RT RIC' performs an internal action '2 AuthN' (Authentication). A yellow callout box next to this step contains the text: 'registration processing authenticate rApp per WG11 requirements assign rAppID'. Step 3: 'Non-RT RIC' sends a message '3 <>Registration response (rAppID)' back to 'rApp'.](1f41c33d59c2c353db34bfe6f762da48_img.jpg) + +Sequence diagram showing the registration process for rApps. The diagram involves two main entities: 'rApp' (represented by a yellow box on the left) and 'Non-RT RIC' (represented by a blue box on the right). The 'Non-RT RIC' contains 'SME functions' at the top and bottom. A horizontal line separates the 'rApp registration' phase from the rest of the process. Step 1: 'rApp' sends a message '1 <>Registration request' to 'Non-RT RIC'. Step 2: 'Non-RT RIC' performs an internal action '2 AuthN' (Authentication). A yellow callout box next to this step contains the text: 'registration processing authenticate rApp per WG11 requirements assign rAppID'. Step 3: 'Non-RT RIC' sends a message '3 <>Registration response (rAppID)' back to 'rApp'. + +Figure 6.13-1: Registration process for rApps + +![Sequence diagram showing the registration process for xApps. The diagram involves two xApp entities and a Near-RT RIC Platform containing two Management Function entities. Step 1: An xApp sends a '«MS» Registration request' to a Management Function. Step 2: The Management Function performs 'AuthN' (authentication). A callout box for this step states: 'registration processing authenticate xApp per WG11 requirements assign xAppID'. Step 3: The Management Function sends a '«MS» Registration response (xAppID)' back to the xApp. A horizontal line labeled 'xApp registration' spans the top of the diagram.](912ad24d58749e2145fb818596096c1e_img.jpg) + +``` + +sequenceDiagram + participant xApp1 as xApp + participant MF1 as Management Function + participant MF2 as Management Function + participant xApp2 as xApp + + xApp1->>MF1: 1 «MS» Registration request + MF1->>MF2: 2 AuthN + MF2-->>MF1: + MF2-->>xApp2: 3 «MS» Registration response (xAppID) + + Note right of MF2: registration processing +authenticate xApp per WG11 requirements +assign xAppID + +``` + +Sequence diagram showing the registration process for xApps. The diagram involves two xApp entities and a Near-RT RIC Platform containing two Management Function entities. Step 1: An xApp sends a '«MS» Registration request' to a Management Function. Step 2: The Management Function performs 'AuthN' (authentication). A callout box for this step states: 'registration processing authenticate xApp per WG11 requirements assign xAppID'. Step 3: The Management Function sends a '«MS» Registration response (xAppID)' back to the xApp. A horizontal line labeled 'xApp registration' spans the top of the diagram. + +**Figure 6.13-2: Registration process for xApps** + +This solution defines a general procedure for authenticating applications during the registration process as specified by WG2 R1 Use Cases and Requirements [9] and WG3 RICARCH [10]. The authentication requirements should be defined in WG11 Security Requirements and Controls TS. + +# 7 Conclusions + +## 7.1 Key Issue Solution Mapping + +This document currently contains 16 key issues across the application life cycle stages and 13 solutions proposals to address or reduce the risk associated with the key issues. The solutions are listed here for reference, followed by a mapping of the proposed solutions to the key issues in Table 7.1-1. + +- Solution #1: Application Package Authenticity and Integrity +- Solution #2: Secure Update of Applications +- Solution #3: Application Security Descriptor +- Solution #4: Secure Logging and Monitoring for Applications +- Solution #5: Software Bill of Materials Requirement for Applications +- Solution #6: Recommendations for Vulnerability Scanning +- Solution #7: Recommendations for Addressing Application Vulnerabilities +- Solution #8: PNF Software Lifecycle Security Recommendations +- Solution #9: Application Integrity during Operation +- Solution #10: Secure Decommissioning of Applications +- Solution #11: Secure Deletion of Sensitive Data +- Solution #12: rAppID Uniqueness +- Solution #13: Secure Application Registration Procedure + +**Table 7.1-1 - Mapping of Key Issues to Solutions** + +| Key issue | O-RAN
Security
Req. TS
| Sol.
#1
| Sol.
#2
| Sol.
#3
| Sol.
#4
| Sol.
#5
| Sol.
#6
| Sol.
#7
| Sol.
#8
| Sol.
#9
| Sol.
#10
| Sol.
#11
| Sol.
#12
| Sol.
#13
| +|------------------------------------------------------------------|---------------------------------------|--------------------|--------------------|--------------------|--------------------|--------------------|--------------------|--------------------|--------------------|--------------------|---------------------|---------------------|---------------------|---------------------| +| Dev-1: Package Authenticity and Integrity | X | X | | | | | | | | | | | | | +| Dev-2: Software Bill of Materials (SBOM) for Applications | X | | | | | X | | | | | | | | | +| Dev-3: Security Descriptor | X | | | X | | | | | | | | | | | +| Onboard-1: Initial Authentication of Application Package | X | X | | | | | | | | | | | | | +| Onboard-2: Image Tampering during Application Onboarding | X | X | | | | | | | | | | | | | +| Onboard-3: Risk of Deploying a Malicious Application | X | X | | | | | X | | | | | | | | +| Onboard-4: rApp ID Abuse | | | | | | | | | | | | | X | | + +| | | | | | | | | | | | | | | | +|--------------------------------------------------------------|---|---|---|--|---|--|---|---|---|---|---|---|--|---| +| Onboard-5: Registration of Applications | | | | | | | | | | | | | | X | +| Op-1: Security for Application Updates | X | | X | | | | | | | | | | | | +| Op-2: Application Integrity during Operation | X | X | | | | | X | X | | X | | | | | +| Op-3: Security Logging and Monitoring of Applications | X | | | | X | | | | | | | | | | +| Op-4: Secure Decommissioning of Applications | X | | | | | | | | | | X | X | | | +| Op-5: Exploitation of Application Vulnerabilities | X | | | | | | X | X | | | | | | | +| Op-6: PNF Software Lifecycle Security | | | | | | | | | X | | | | | | +| Op-7: Application Misconfiguration | X | | | | | | | | | | | | | | +| Op-8: Secure Deletion of Sensitive Data | X | | | | | | | | | | | X | | | + +## 7.2 Recommendations + +The following is a list of next steps and recommendations coming from this work item which will be addressed in future updates to this technical report and other O-RAN specifications. + +**Recommendation 1:** This work item should define additional recommendations and requirements for secure decommissioning and deletion of sensitive data for applications. CRs will be generated. + +**Recommendation 2:** This work item should continue contributing to the WG11 Security Requirements and Controls Specifications [2] with new requirements and security controls from the solutions outlined in this report. CRs will be generated. + +**Recommendation 3:** This work item should contribute security test cases for relevant security requirements to the WG11 Security Test specifications [27]. CRs will be generated. + +**Recommendation 4:** This work item should collaborate with other WG11 work items and other work groups on security verification during the application registration procedure for xApps and rApps. + +**Recommendation 5:** WG11 should collaborate with WG6 and WG10 to ensure the WG11 security specifications are appropriately referenced by WG6 and WG10 in their specifications. + +# --- History + +| Date | Revision | Description | +|------------|----------|-----------------------------------------------| +| 2022.11.14 | v01.00 | First release, Version 1 of Technical Report | +| 2023.02.24 | v02.00 | Second release, Version 2 of Technical Report | +| 2023.11.03 | v03.00 | Third release, Version 3 of Technical Report | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/079e02d5b09a646342bbfb2ea862fa81_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/079e02d5b09a646342bbfb2ea862fa81_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4fa99708b8180bd4316c910df64e90f779d832a9 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/079e02d5b09a646342bbfb2ea862fa81_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e02f5c22b3f7efb77bdd4493ef4d012a6e8f87c58732ab0ee8d29a9bc916c96 +size 58650 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/17007e88d73d5cbd5519a68ca855e792_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/17007e88d73d5cbd5519a68ca855e792_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..028db8249c2b8100e7cbe1092f20256d7ea841f7 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/17007e88d73d5cbd5519a68ca855e792_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:642a5e72e16bd860d18f756a2406a069d40941329b6bb3f6b2a25326149ddc7a +size 66952 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/18b5fb33f7aac3096bc5195f8fa7a025_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/18b5fb33f7aac3096bc5195f8fa7a025_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f85c56cba95a9fdd352a4bbde6e2c96917cc4ee9 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/18b5fb33f7aac3096bc5195f8fa7a025_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4db047e9722e6466c277bfa0c1679cdd6d2a0a45d480980afaf72f97aadf395c +size 46610 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/1efb8dd22660d09ff7e341ed6d114b1a_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/1efb8dd22660d09ff7e341ed6d114b1a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..675de3b501098730832179be273d9f14086f103d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/1efb8dd22660d09ff7e341ed6d114b1a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7ba5e7a748182593fc40140a23a5333b13a464a26edba5b9d5553f32d6f57f4c +size 4229 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/1f4a755880ec884c749645a8b354cb24_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/1f4a755880ec884c749645a8b354cb24_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cb8f0c7f368bd428300f4c7cb79314b057f15893 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/1f4a755880ec884c749645a8b354cb24_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6f34ce5463e4d0ea8226b526d416f62a39b1db1d66a16fbf0c91dcda1c50fdf8 +size 43410 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/307b416dc3cadad68af189331058fc3d_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/307b416dc3cadad68af189331058fc3d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..74ed3e66f64595dcee65c3c8e2fb6bb0aab20ea1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/307b416dc3cadad68af189331058fc3d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f42f7a61a3fd4faa086db32f79f3df45d598e5cf162cef8897067cd778f87901 +size 38686 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/3403492e0dc24cbc025eb675eb86245f_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/3403492e0dc24cbc025eb675eb86245f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..01f614a1e0e5648a0339df067b86427c2fe9235a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/3403492e0dc24cbc025eb675eb86245f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a683579c8b933ad9017cc5b1f2298ecddc35a3de23928756863e48366ef64b96 +size 4116 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/3ea0f3866b1d87d30d1ee575085c7d35_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/3ea0f3866b1d87d30d1ee575085c7d35_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ce8a49588de68b4c7f53213c0a8e89e511e61e69 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/3ea0f3866b1d87d30d1ee575085c7d35_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d02fdb4fc0454f3c1ced7a5cc64b5471f4e1d3d194368da219411322364c32aa +size 73594 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/3ee904708d309edeed423952cd8bc283_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/3ee904708d309edeed423952cd8bc283_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d795135e41f86b4e4e255696b3d1a7e181035d88 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/3ee904708d309edeed423952cd8bc283_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0bbec222c47fce9739ef1fde93320d022e7b05cbe10718a701de0a1a2de629ed +size 78698 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/4730faae08b7e31f0c52317f4cd78595_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/4730faae08b7e31f0c52317f4cd78595_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b4e23b7b187f2dc53e6c6f42c7ca6dfc21a2c464 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/4730faae08b7e31f0c52317f4cd78595_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:619f2880c61941444bf37233d70322daf914000032758a0c340bc440a0e09020 +size 77291 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/49b6175ee3d33a1d0d0037ef76074d39_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/49b6175ee3d33a1d0d0037ef76074d39_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6d3b5e76ddf96684e98d410ef801d95b446c2785 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/49b6175ee3d33a1d0d0037ef76074d39_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:37c2da6725309561e7991c19a53e8c1f33be9008b322cef9db89f91969e11201 +size 4205 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/4a705d49812d6231d2083e7f42cada54_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/4a705d49812d6231d2083e7f42cada54_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..19ad5b9292108ce1764d17c4b2fee67c9ed38d2f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/4a705d49812d6231d2083e7f42cada54_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0eba39b014dd0639d7278f1281d805b055b1072918febcb686ab895d756896ad +size 33284 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/515fd40b0496ecf9334edd56e11147c0_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/515fd40b0496ecf9334edd56e11147c0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ea290c9044120d9f5450015791b50b9deceab504 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/515fd40b0496ecf9334edd56e11147c0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:af38a24b372c7c27eb9edf1f6a97f14cbf27c7ef1a1bcd00134a1e3c1e116fe9 +size 92052 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..44e4ca1e706fffc218594e75b7fbdfaeee43149d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ba36991bdae993881d357810ae680e8b2718eeb75c0831521a0cdc2d6e038f2 +size 4147 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/748e693ac46aa6e5ddc045a2f3f43cc5_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/748e693ac46aa6e5ddc045a2f3f43cc5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9bd49249405e78dafca9bf929c70ff457c8c5ebd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/748e693ac46aa6e5ddc045a2f3f43cc5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1c418ce4560cc06fb07fe8a04cab77849ad15fe46bcf55b6f11c60583f808e03 +size 4228 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/790746e3dcd66af9d66f695c9dec4534_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/790746e3dcd66af9d66f695c9dec4534_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0a2ceb0b6f6d03e4981c98d926c97087c0898c20 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/790746e3dcd66af9d66f695c9dec4534_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c07adc1c18eaf5357d9a13a014c630705ca00110a890c1355a9e009281ee94b9 +size 4040 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/92fadb378b90c725ee5d1144561ed429_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/92fadb378b90c725ee5d1144561ed429_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..76cfc90557c538f094f2700bf0d0b262f91a7bb6 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/92fadb378b90c725ee5d1144561ed429_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4b5c49dc1ddc519b0b608282280883aee6aaea1172e8257664625924efbf4bfd +size 51492 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/958ec48f78723ce7eab31b4f417b6f6c_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/958ec48f78723ce7eab31b4f417b6f6c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..465aeb9e96dd81ab3fd7b298643769ccb3bc1441 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/958ec48f78723ce7eab31b4f417b6f6c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cc377e923763383c23ad65b0695c482e943038313da205463618b8588de75f32 +size 50374 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/9c8a8a87d6566b6a82a2e59f7c5f55d4_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/9c8a8a87d6566b6a82a2e59f7c5f55d4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3ace00b62b83646ecb0e2ecf07e84c4bd0b8946d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/9c8a8a87d6566b6a82a2e59f7c5f55d4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ad3f88362f3f9735151e33e4c5cb11d5402a9bdfcb889b548432171cb78ed4eb +size 108043 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/9fc87a46cd2ba9c63014d1142fe15d13_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/9fc87a46cd2ba9c63014d1142fe15d13_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0d941f65258b4dff27f4fd8893e179751e943f5d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/9fc87a46cd2ba9c63014d1142fe15d13_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2aeb219b26f9b2ae8ca90d8cb9239961af86ec578f1dcaae222b8bcd1c6cf88a +size 78180 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/a71f57b0d2d79fd352e551f9580a2602_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/a71f57b0d2d79fd352e551f9580a2602_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7fc15187cd6815079a447a1fee5f18887ebb53f4 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/a71f57b0d2d79fd352e551f9580a2602_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:931348596c4a230443fe4b96b7cb14ea4e4a4a39c99ca8503eb9d2f817d0cf49 +size 74994 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/d11ea352254574022d9ef7922e32d7b9_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/d11ea352254574022d9ef7922e32d7b9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fafc2088d09c9950ea1e2b4c2c113d005c3b9d75 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/d11ea352254574022d9ef7922e32d7b9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8beff93d083899467b905e65de11bd966c3b9d05ec09610145d09c85713a91c0 +size 73344 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/eed97810b73ce2008906a0918abed322_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/eed97810b73ce2008906a0918abed322_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e9d056186f91071754a1bd66cc5b0f58f9cdcd1d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/eed97810b73ce2008906a0918abed322_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a6feea577002af775f92c1c073ef8e278549447e23549760a568e59d2a4c42d6 +size 4142 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/fa49186bb622c095765fd8ddc772729a_img.jpg b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/fa49186bb622c095765fd8ddc772729a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1af4baa9997cb759fd2b6a6708563bc34a058214 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/fa49186bb622c095765fd8ddc772729a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b7de6899a3e71e7d5cb96e3cf5688867518bde70faaa5a1d8d15817d1aa6097 +size 4042 diff --git a/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/raw.md b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..c89ec4ac8dfff3e7a4b76ff81bacd8d5e12bea32 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00/raw.md @@ -0,0 +1,2304 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****Study on Certificate Management Framework** + +# Contents + +| | | | +|--------|---------------------------------------------------------------------------------------------------------------------------|----| +| 1 | Introduction..... | 10 | +| 1.1 | Scope..... | 10 | +| 2 | References, Definitions, Terms and Abbreviations ..... | 11 | +| 2.1 | Informative References ..... | 11 | +| 2.2 | Definitions and Abbreviations ..... | 13 | +| 2.2.1 | Definitions ..... | 13 | +| 2.2.2 | Abbreviations and acronyms ..... | 14 | +| 2.2.3 | Terms..... | 15 | +| 3 | Architecture Requirements and Assumptions..... | 16 | +| 3.1 | Architecture Requirements..... | 16 | +| 3.2 | Architecture Assumptions..... | 16 | +| 3.2.1 | Use Case for Physical Network Functions ..... | 16 | +| 4 | Key Issues ..... | 18 | +| 4.1 | Key Issue #1: Considering RA and CA as separate logical entities..... | 18 | +| 4.1.1 | General Description..... | 18 | +| 4.1.2 | Security Threats..... | 18 | +| 4.2 | Key Issue #2: Usage of PSK/Refnum for Initial Certificate Enrolment of PNFs ..... | 18 | +| 4.2.1 | General Description..... | 18 | +| 4.2.2 | Security Threats..... | 19 | +| 4.3 | Key Issue #3: Usage of Vendor Certificates for Initial Certificate Enrolment of PNFs ..... | 19 | +| 4.3.1 | General Description..... | 19 | +| 4.3.2 | Security Threats..... | 19 | +| 4.4 | Key Issue #4: Void..... | 19 | +| 4.5 | Key Issue #5: Void..... | 19 | +| 4.6 | Key Issue #6: Initial Certificate Enrolment for new NFs..... | 19 | +| 4.6.1 | General Description..... | 19 | +| 4.6.2 | Security Threats..... | 19 | +| 4.7 | Key Issue #7: Void..... | 20 | +| 4.8 | Key Issue #8: Vendor Root CA Certificate Renewal..... | 20 | +| 4.8.1 | General Description..... | 20 | +| 4.8.2 | Security Threats..... | 20 | +| 4.9 | Key Issue #9: Void..... | 20 | +| 4.10 | Key Issue #10: Procedure for Certificate Updates when revoked certificates are detected by NFs ..... | 20 | +| 4.10.1 | General Description..... | 20 | +| 4.10.2 | Security Threats..... | 21 | +| 4.11 | Key Issue #11: Void..... | 21 | +| 4.12 | Key Issue #12: Certificate to name mapping ..... | 21 | +| 4.12.1 | General Description..... | 21 | +| 4.12.2 | Security Threats..... | 21 | +| 4.13 | Key Issue #13: System overload due to bulk certificate updates ..... | 22 | +| 4.13.1 | General Description..... | 22 | +| 4.13.2 | Security Threats..... | 22 | +| 4.14 | Key Issue #14: Void..... | 23 | +| 4.15 | Key Issue #15: Void..... | 23 | +| 4.16 | Key Issue #16: Void..... | 23 | +| 4.17 | Key Issue #17: Void..... | 23 | +| 4.18 | Key Issue #18: Allow Flexibility in the Number of Operator Certificates Associated with each end entity / Interface ..... | 23 | +| 4.18.1 | General Description..... | 23 | +| 4.18.2 | Security Threats..... | 23 | +| 4.19 | Key Issue #19: Certificate Management in Distributed Cluster Processing ..... | 24 | +| 4.19.1 | General Description..... | 24 | +| 4.19.2 | Security Threats..... | 24 | +| 4.20 | Key Issue #20: Certificate Management and Secure Storage of Application Private Keys ..... | 25 | +| 4.20.1 | General Description..... | 25 | +| 4.20.2 | Security Threats..... | 25 | + +| | | | +|--------|----------------------------------------------------------------------------------------------------------|----| +| 4.21 | Key Issue #21: Coordinating Certificate Management with VNF/CNF Lifecycle Activities ..... | 25 | +| 4.21.1 | General Description..... | 25 | +| 4.21.2 | Security Threats..... | 26 | +| 4.22 | Key Issue #22: Supporting Public and Private Certificate Authorities (CA)..... | 26 | +| 4.22.1 | General Description..... | 26 | +| 4.22.2 | Security Threats..... | 26 | +| 4.23 | Key Issue #23: Distribution of Intermediate and Root Certificates ..... | 27 | +| 4.23.1 | General Description..... | 27 | +| 4.23.2 | Security Threats..... | 27 | +| 4.24 | Key Issue #24: CMPv2 Message Minimal Set and Robustness..... | 28 | +| 4.24.1 | General Description..... | 28 | +| 4.24.2 | Security Threats..... | 28 | +| 4.25 | Key Issue #25: RA and CA Capacity Estimation, Renewal Intervals and Credential Strength ..... | 28 | +| 4.25.1 | General Description..... | 28 | +| 4.25.2 | Security Threats..... | 28 | +| 4.26 | Key Issue #26: Namespace Conventions ..... | 29 | +| 4.26.1 | General Description..... | 29 | +| 4.26.2 | Security Threats..... | 29 | +| 4.27 | Key issue #27: Handling of certificate revocation in O-RAN ..... | 29 | +| 4.27.1 | General Description..... | 29 | +| 4.27.2 | Security Threats..... | 30 | +| 4.28 | Key issue #28: Risk of Service un-availability due to root CA Certificate updates for CNFs and VNFs..... | 30 | +| 4.28.1 | General Description..... | 30 | +| 4.28.2 | Security Threats..... | 31 | +| 4.29 | Key issue #29: Certificate requirements for O-Cloud control plane..... | 31 | +| 4.29.1 | General Description..... | 31 | +| 4.29.2 | Security Threats..... | 32 | +| 4.30 | Key issue #30: Certificate management for cloud deployment models..... | 32 | +| 4.30.1 | General Description..... | 32 | +| 4.30.2 | Security Threats..... | 32 | +| 4.31 | Key issue #31: Void..... | 32 | +| 4.32 | Key issue #32: Void..... | 33 | +| 4.33 | Key issue #33: Certificate Profiling in O-RAN ..... | 33 | +| 4.33.1 | General Description..... | 33 | +| 4.33.2 | Security Threats..... | 33 | +| 4.34 | Key issue #34: Void..... | 33 | +| 4.35 | Key issue #35: Void..... | 34 | +| 4.36 | Key issue #36: Certificate sharing or not-sharing in Apps/VNFs/CNFs ..... | 34 | +| 4.36.1 | General Description..... | 34 | +| 4.36.2 | Security Threats..... | 34 | +| 4.37 | Key issue #37: Lightweight solution..... | 35 | +| 4.37.1 | General Description..... | 35 | +| 4.37.2 | Security Threats..... | 35 | +| 4.38 | Key issue #38: Interoperability ..... | 35 | +| 4.38.1 | General Description..... | 35 | +| 4.38.2 | Security Threats..... | 35 | +| 4.39 | Key issue #39: Crypto agility..... | 36 | +| 4.39.1 | General Description..... | 36 | +| 4.39.2 | Security Threats..... | 36 | +| 4.40 | Key issue #40: Void..... | 36 | +| 4.41 | Key Issue #41: CMPv2 ..... | 36 | +| 4.41.1 | General Description..... | 36 | +| 4.41.2 | Security Threats..... | 36 | +| 4.42 | Key Issue #42: Certificate management for Shared O-RU ..... | 36 | +| 4.42.1 | General Description..... | 36 | +| 4.42.2 | Security Threats..... | 37 | +| 4.43 | Key Issue #43: NF with an expired certificate ..... | 37 | +| 4.43.1 | General Description..... | 37 | +| 4.43.2 | Security Threats..... | 37 | +| 5 | Solutions..... | 38 | +| 5.1 | Solution #1: Automation of PSK/Refnum based Certificate Enrolment..... | 38 | + +| | | | +|--------|---------------------------------------------------------------------------------------------------------|----| +| 5.1.1 | Description ..... | 38 | +| 5.1.2 | Impacts on Existing Interfaces and Functionality ..... | 38 | +| 5.1.3 | Solution Evaluation ..... | 38 | +| 5.1.4 | Potential Security Requirements ..... | 38 | +| 5.2 | Solution #2: Study the use of BRSKI..... | 38 | +| 5.2.1 | Description ..... | 38 | +| 5.2.2 | Impacts on Existing Interfaces and Functionality ..... | 39 | +| 5.2.3 | Solution Evaluation ..... | 39 | +| 5.2.4 | Potential Security Requirements ..... | 40 | +| 5.3 | Solution #3: Study the use of EST ..... | 40 | +| 5.3.1 | Description ..... | 40 | +| 5.3.2 | Impacts on Existing Interfaces and Functionality ..... | 42 | +| 5.3.3 | Solution Evaluation ..... | 42 | +| 5.3.4 | Potential Security Requirements ..... | 42 | +| 5.4 | Solution #4: Study the use of ACME..... | 42 | +| 5.4.1 | Description ..... | 42 | +| 5.4.2 | Impacts on Existing Interfaces and Functionality ..... | 44 | +| 5.4.3 | Solution Evaluation ..... | 44 | +| 5.5 | Solution #5: Initial Certificate Enrolment of PNFs using vendor certificates ..... | 45 | +| 5.5.1 | Description ..... | 45 | +| 5.5.2 | Impacts on Existing Interfaces and Functionality ..... | 45 | +| 5.5.3 | Solution Evaluation ..... | 46 | +| 5.5.4 | Potential Security Requirements ..... | 46 | +| 5.6 | Solution #6: Certificate management and secure storage of Application private keys within O-Cloud ..... | 46 | +| 5.6.1 | Description ..... | 46 | +| 5.6.2 | Generation of key pair and modes of operation ..... | 46 | +| 5.6.3 | Secure key and file storage..... | 50 | +| 5.6.4 | Impacts on Existing Interfaces and Functionality ..... | 53 | +| 5.6.5 | Solution Evaluation ..... | 53 | +| 5.6.6 | Potential Security Requirements ..... | 53 | +| 5.7 | Solution #7: CMPv2..... | 54 | +| 5.7.1 | Description ..... | 54 | +| 5.7.2 | Impacts on Existing Interfaces and Functionality ..... | 54 | +| 5.7.3 | Solution Evaluation ..... | 54 | +| 5.7.4 | Potential Security Requirements ..... | 54 | +| 5.8 | Solution #8: Vendor Root CA Certificate Renewal notification..... | 55 | +| 5.8.1 | Description ..... | 55 | +| 5.8.2 | Impacts on Existing Interfaces and Functionality ..... | 55 | +| 5.8.3 | Solution Evaluation ..... | 55 | +| 5.8.4 | Potential Security Requirements ..... | 56 | +| 5.9 | Solution #9: Mitigating the risk of system overload due to bulk certificate updates..... | 56 | +| 5.9.1 | Description ..... | 56 | +| 5.9.2 | Impacts on Existing Interfaces and Functionality ..... | 57 | +| 5.9.3 | Solution Evaluation ..... | 57 | +| 5.9.4 | Potential Security Requirements ..... | 57 | +| 5.10 | Solution #10: Usage of PSK/Refnum for Initial Certificate Enrolment for PNFs ..... | 57 | +| 5.10.1 | Description ..... | 57 | +| 5.10.2 | Impacts on Existing Interfaces and Functionality ..... | 58 | +| 5.10.3 | Solution Evaluation ..... | 58 | +| 5.10.4 | Potential Security Requirements ..... | 58 | +| 5.11 | Solution #11: Certificate renewal procedure..... | 58 | +| 5.11.1 | Description ..... | 58 | +| 5.11.2 | Impacts on Existing Interfaces and Functionality ..... | 59 | +| 5.11.3 | Solution Evaluation ..... | 59 | +| 5.11.4 | Potential Security Requirements ..... | 60 | +| 5.12 | Solution #12: Certificate Profile for O-RAN TLS Entity ..... | 60 | +| 5.12.1 | Description ..... | 60 | +| 5.12.2 | Impacts on Existing Interfaces and Functionality ..... | 61 | +| 5.12.3 | Solution Evaluation ..... | 61 | +| 5.12.4 | Potential Security Requirements ..... | 63 | +| 5.13 | Solution #13: Identifying RA and CA as separate logical entities with flexible deployment options..... | 63 | + +| | | | +|--------|---------------------------------------------------------------------------------------------|----| +| 5.13.1 | General Description..... | 63 | +| 5.13.2 | Impacts on Existing Interfaces and Functionality ..... | 64 | +| 5.13.3 | Solution Evaluation ..... | 64 | +| 5.13.4 | Potential Security Requirements ..... | 64 | +| 5.14 | Solution #14: Securing Root CA Private Key..... | 65 | +| 5.14.1 | General Description..... | 65 | +| 5.14.2 | Impacts on Existing Interfaces and Functionality ..... | 65 | +| 5.14.3 | Solution Evaluation ..... | 65 | +| 5.14.4 | Potential Security Requirements ..... | 65 | +| 5.15 | Solution #15: Certificate enrolment for new NF Deployment using CMPv2..... | 66 | +| 5.15.1 | General Description..... | 66 | +| 5.15.2 | Impacts on Existing Interfaces and Functionality ..... | 68 | +| 5.15.3 | Solution Evaluation ..... | 68 | +| 5.15.4 | Potential Security Requirements ..... | 68 | +| 6 | Conclusions..... | 69 | +| 6.1 | Key Issue #41: CMPv2 ..... | 69 | +| 6.2 | ACME as Optional Certificate Management Protocol..... | 69 | +| 6.3 | Usage of PSK/Refnum for initial certificate enrolment for PNFs, CNFs and VNFs..... | 69 | +| 6.4 | Vendor root CA certificate renewal notification..... | 69 | +| 6.5 | Initial certificate enrolment for PNFs using vendor certificates ..... | 70 | +| 6.6 | Certificate renewal procedure ..... | 70 | +| 6.7 | RA and CA as separate logical entities ..... | 70 | +| 6.8 | EST as Optional Certificate Management Protocol ..... | 70 | +| 6.9 | Use of BRSKI in O-RAN..... | 70 | +| 6.10 | Mitigating the risk of system overload due to bulk certificate update ..... | 70 | +| 6.11 | Key Issue #20: Certificate Management and Secure Storage of Private Keys ..... | 71 | +| 6.11.1 | Evaluation and Assessment for local security module managed by SSRM within the O-Cloud..... | 71 | +| 6.11.2 | Evaluation and Assessment for the KMS..... | 71 | +| 6.11.3 | Conclusion..... | 72 | +| 6.12 | Cert Profile for O-RAN TLS Entity..... | 72 | +| 6.13 | Certificate enrollment for new NF Deployment using CMPv2 ..... | 72 | +| 7 | Key Issues-Solutions mapping..... | 73 | +| | Annex: Change history/Change request (history) ..... | 74 | + +# List of Figures + +| | | +|-------------------------------------------------------------------------------------------------------|----| +| Figure 3-1: Logical Architecture of O-RAN system: Overview of the security architecture ..... | 16 | +| Figure 4-1: A possible system comprising different applications with different Root Certificates..... | 31 | +| Figure 5-1: Certificate-less TLS Authentication..... | 41 | +| Figure 5-2: Certificate-based TLS Authentication..... | 41 | +| Figure 5-3: A simplified depiction of the workings of ACME ..... | 43 | +| Figure 5-4: Secure Storage and Certificate Management Architecture (System Level View) ..... | 47 | +| Figure 5-5: Key-generation by the Virtualisation Platform ..... | 48 | +| Figure 5-6: Key-generation by the Trusted Application ..... | 49 | +| Figure 5-7: Key-generation by the Secure Module (e.g., HSM, TPM) ..... | 50 | +| Figure 5-8: Secure Key and File Storage Architecture Framework (overview) ..... | 51 | +| Figure 5-9: Scenarios for protecting keys within the secret storage volume based on TPM..... | 52 | +| Figure 5-10: Key protection based on KMS ..... | 52 | +| Figure 5-11: Certificate Update Orchestrator..... | 57 | +| Figure 5-12: Certificate renewal procedure ..... | 59 | +| Figure 5-13 Certificate enrollment for new NF Deployment..... | 68 | + +# 1 Introduction + +## 1.1 Scope + +This technical report studies a comprehensive framework for certificate management across the O-RAN environment. + +The objectives of this study are to identify key issues, potential security requirements, solutions, and specifications to + +- Standardize a certificate management framework comprising protocols and procedures for certificate life cycle events (e.g. enrolment, renewal, revocation) within the O-RAN architecture (e.g., O-CU, O-DU, O-RU, Open Fronthaul, Non-RT-RIC, Near-RT-RIC, etc.) +- Address the following objectives: + - Support reuse of IETF CMPv2 certificate management + - Explore the IETF ACME, IETF BRSKI, IETF EST, and other industry efforts as potential components for a certificate management framework. + - Establish lifecycle service models to bring zero touch automation to the certificate management framework. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +1 version xx.yy.zz + +2 where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# 2 References, Definitions, Terms and Abbreviations + +## 2.1 Informative References + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +[i.1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications" + +[i.2] 3GPP TR 33.310: "Network Domain Security (NDS); Authentication Framework (AF)" + +[i.3] O-RAN ALLIANCE TS: "O-RAN Management Plane Specification" + +[i.4] RFC-6187: X.509v3 Certificates for Secure Shell Authentication + +[i.5] IETF RFC 4210: Internet X.509 Public Key Infrastructure Certificate Management Protocol (CMP) + +[i.6] Design and build a privately hosted Public Key Infrastructure + + + +[i.7] NIST SP 1800-16C: Securing Web Transactions: TLS Server Certificate Management + + + +[i.8] 3GPP TS 32.509: "Data formats for multi-vendor plug and play eNode B connection to the network" + +[i.9] Void + +[i.10] Void + +[i.11] ETSI GR NFV-SEC 005, NFV, trust, report on certificate management + +[i.12] ETSI GR NFV-IFA 029, Report on the Enhancements of the NFV architecture towards "Cloud-native" and "PaaS" + +[i.13] IETF RFC 5280: Internet X.509 Public Key Infrastructure Certificate and Certificate Revocation List (CRL) Profile + +[i.14] IETF RFC 5246: The Transport Layer Security (TLS) Protocol Version 1.2 + +[i.15] IETF RFC 8446: The Transport Layer Security (TLS) Protocol Version 1.3 + +[i.16] IETF RFC 7540: Hypertext Transfer Protocol Version 2 (HTTP/2) + +[i.17] IETF RFC 6066: Transport Layer Security (TLS) Extensions: Extension Definitions + +[i.18] IETF RFC 6125: Representation and Verification of Domain-Based Application Service Identity within Internet Public Key Infrastructure Using X.509 (PKIX) Certificates in the Context of Transport Layer Security (TLS) + +[i.19] IETF RFC 7633: X.509v3 Transport Layer Security (TLS) Feature Extension + +[i.20] CA-Browser-Forum-BR-1.8.0: Baseline Requirements for the Issuance and Management of Publicly-Trusted Certificates, August 2021, . + +- [i.21] IETF RFC 6347: Datagram Transport Layer Security Version 1.2 +- [i.22] IETF RFC 9325: Recommendations for Secure Use of Transport Layer Security (TLS) and Datagram Transport Layer Security (DTLS) +- [i.23] Service Identity in TLS +- [i.24] IETF RFC 7093: Additional Methods for Generating Key Identifiers Values +- [i.25] NIST Special Publication 800-52 Revision 2: Guidelines for the Selection, Configuration, and Use of Transport Layer Security (TLS) Implementations +- [i.26] IETF RFC 6960: X.509 Internet Public Key Infrastructure Online Certificate Status Protocol - OCSP +- [i.27] IETF RFC 3647: Internet X.509 Public Key Infrastructure Certificate Policy and Certification Practices Framework +- [i.28] RFC 8995: Bootstrapping Remote Secure Key Infrastructure (BRSKI) +- [i.29] RFC 8993: A Reference Model for Autonomic Networking +- [i.30] RFC 8994: An Autonomic Control Plane (ACP) +- [i.31] RFC 8572: Secure Zero Touch Provisioning (SZTP) +- [i.32] IETF RFC 7030: Enrollment over Secure Transport +- [i.33] IETF RFC 5054: Using the Secure Remote Password (SRP) Protocol for TLS Authentication +- [i.34] IETF RFC 8295: EST (Enrollment over Secure Transport) Extensions +- [i.35] IETF RFC 5272: Certificate Management over CMS +- [i.36] IETF RFC 8951: Clarification of Enrollment over Secure Transport (EST): Transfer Encodings and ASN.1 +- [i.37] IETF RFC 8996: Deprecating TLS 1.0 and TLS 1.1 +- [i.38] IETF RFC 7231: Hypertext Transfer Protocol (HTTP/1.1): Semantics and Content +- [i.39] IETF RFC 3986: Uniform Resource Identifier (URI): Generic Syntax +- [i.40] IETF RFC 2119: Key words for use in RFCs to Indicate Requirement Levels +- [i.41] O-RAN ALLIANCE TS: "Security Protocols Specifications" +- [i.42] IETF RFC 8555: Automatic Certificate Management Environment (ACME) +- [i.43] IETF RFC 8738: Automated Certificate Management Environment (ACME) IP Identifier Validation Extension +- [i.44] 3GPP TS 28.315: "Management and orchestration; Plug and connect; Procedure flows" +- [i.45] 3GPP TS 28.314: "Management and orchestration; Plug and connect; Concepts and requirements" +- [i.46] ETSI GR NFV-SEC 009, NFV Security,"Report on use cases and technical approaches for multi-layer host administration" +- [i.47] O-RAN ALLIANCE TS: "Security Requirements and Controls Specification" +- [i.48] Cryptographic Key Generation: NIST Publishes SP 800-133 Rev. 2, +- [i.49] SOG-IS Agreed Cryptographic Mechanisms v1.3, +- [i.50] NIST Special Publication 800-57 Part 1 Revision 5: Recommendation for Key Management +- [i.51] O-RAN ALLIANCE TS: "O-RAN Architecture Description" + +[i.52] O-RAN ALLIANCE TS: "Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN" + +## 2.2 Definitions and Abbreviations + +### 2.2.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [i.1] and the following apply: + +**A1:** Interface between Non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**A1 policy:** Type of declarative policies expressed using formal statements that enable the Non-RT RIC function in the SMO to guide the Near-RT RIC function, and hence the RAN, towards better fulfilment of the RAN intent. + +**A1 Enrichment information:** Information utilized by Near-RT RIC that is collected or derived at SMO/Non-RT RIC either from non-network data sources or from network functions themselves. + +**E2:** Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. + +**E2 Node:** a logical node terminating E2 interface. In this version of the specification, O-RAN nodes terminating E2 interface are: + +- for NR access: O-CU-CP, O-CU-UP, O-DU or any combination. +- for E-UTRA access: O-eNB. + +**FCAPS:** Fault, Configuration, Accounting, Performance, Security. + +**Intents:** A declarative policy to steer or guide the behavior of RAN functions, allowing the RAN function to calculate the optimal result to achieve stated objective. + +**Near-RT RIC:** O-RAN near-real-time RAN Intelligent Controller: a logical function that enables real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. + +**Non-RT RIC:** O-RAN non-real-time RAN Intelligent Controller: a logical function that enables non-real-time control and optimization of RAN elements and resources, AI/ML workflow including model training and updates, and policy-based guidance of applications/features in Near-RT RIC. + +**O-CU:** O-RAN Central Unit: a logical node hosting O-CU-CP and O-CU-UP + +**O-CU-CP:** O-RAN Central Unit – Control Plane: a logical node hosting the RRC and the control plane part of the PDCP protocol. + +**O-CU-UP:** O-RAN Central Unit – User Plane: a logical node hosting the user plane part of the PDCP protocol and the SDAP protocol. + +**O-DU:** O-RAN Distributed Unit: a logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. + +**O-RU:** O-RAN Radio Unit: a logical node hosting Low-PHY layer and RF processing based on a lower layer functional split. This is similar to 3GPP's "TRP" or "RRH" but more specific in including the Low-PHY layer (FFT/iFFT, PRACH extraction). + +**O1:** Interface between management entities (NMS/EMS/MANO) and O-RAN managed elements, for operation and management, by which FCAPS management, Software management, File management shall be achieved. + +**RAN:** Generally referred as Radio Access Network. In terms of this document, any component below Near-RT RIC per O-RAN architecture, including O-CU/O-DU/O-RU. + +**Secure Storage and Retrieval Manager (SSRM):** a component designed to manage the secure storage, retrieval, and lifecycle management of sensitive data, such as cryptographic keys, certificates, and secrets, within the O-Cloud. The + +SSRM acts as an intermediary layer that abstracts the underlying complexities of secure storage mechanisms and provides standardized interfaces for applications and services to interact with secure resources. + +In Kubernetes environments, the combination of the kube-apiserver and cert-manager serves as an embodiment of an SSRM. The kube-apiserver acts as the central entry point for interactions with the Kubernetes control plane, providing authentication, authorization, and a unified API surface. Paired with cert-manager, which automates the management of TLS certificates and abstracts the intricacies of secure storage, this combination streamlines secure communication within Kubernetes clusters. The kube-apiserver offers centralized management, while cert-manager automates the secure storage and retrieval of certificates and private keys, ensuring a seamless and secure experience for applications. + +In OpenStack ecosystems, the collaboration between Keystone and Barbican mirrors the SSRM concept. Keystone functions as the identity and access management service, handling authentication, authorization, and policy enforcement. Complementing Keystone, Barbican operates as a secure key management system, safeguarding cryptographic keys and secrets. Together, Keystone and Barbican provide a standardized approach to secure storage, ensuring sensitive data remains protected while abstracting the complexities of secure key management. + +### 2.2.2 Abbreviations and acronyms + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [i.1] and the following apply: + +| | | +|---------|------------------------------------------------| +| ACME | Automatic Certificate Management Environment | +| ACP | Autonomic Control Plane | +| AI/ML | Artificial Intelligence/Machine Learning | +| ANI | Autonomic Networking Infrastructure | +| BRSKI | Bootstrapping Remote Secure Key Infrastructure | +| CA | Certification Authority | +| CMPv2 | Certificate Management Protocol version 2 | +| CUO | Certificate Update Orchestrator | +| DEK | Disk Encryption Key | +| eNB | eNodeB (applies to LTE) | +| EST | Enrollment over Secure Transport | +| FTP | File Transfer Protocol | +| FTPS | File Transfer Protocol Secure | +| gNB | gNodeB (applies to NR) | +| IPsec | Internet Protocol Security | +| KEK | Key Encryption Key | +| KMS | Key Management System | +| KPI | Key Performance Indicator | +| KQI | Key Quality Indicator | +| LBT | Listen Before Talk | +| LLS | Lower Layer Split | +| MIMO | Multiple Input, Multiple Output | +| MNO | Mobile Network Operator | +| NETCONF | Network Configuration Protocol | +| NF | Network Function | +| NFV | Network Function Virtualisation | +| O-RAN | Open Radio Access Network | + +| | | +|------|-----------------------------------------| +| PDCP | Packet Data Convergence Protocol | +| PNF | Physical Network Function | +| PRB | Physical Resource Block | +| PTP | Precision Timing Protocol | +| QoE | Quality of Experience | +| RA | Registration Authority | +| RBAC | Role-based Access Control | +| RIC | O-RAN RAN Intelligent Controller | +| SDN | Software Defined Network | +| SEK | Secret Encryption Key | +| SINR | Signal-to-Interference-plus-Noise Ratio | +| SMO | Service Management and Orchestration | +| SSH | Secure Shell | +| SSRM | Secure Storage Resource Manager | +| SZTP | Secure Zero Touch Provisioning | +| TLS | Transport Layer Security | +| UAV | Unmanned Aerial Vehicle | +| V2X | Vehicle to Everything | +| VM | Virtual machine | +| VNF | Virtualised Network Function | + +### 2.2.3 Terms + +In this document, the significance of the following words are as defined in the RFC 2119 [i.40] publication by IETF. These words are: + +- "SHALL" This word, or the words "REQUIRED" and "MUST" mean that the process is an absolute requirement of the specification. +- "SHOULD" This word or the adjective "RECOMMENDED" means that there may exist valid reasons in particular circumstances to ignore this item, but the full implications should be understood, and the case carefully weighed before choosing a different course. +- "MAY" This word or the adjective "optional" means that this item is truly optional. One vendor may choose to include the process because a particular marketplace requires it or because it enhances the product, for example, another vendor may omit the same item. + +# 3 Architecture Requirements and Assumptions + +## 3.1 Architecture Requirements + +The Certificate Management Framework Architecture should be compatible with the M-Plane Certificate Management Framework specified in O-RAN Management Plane Specification [i.3]. These certificates conform to the X.509v3 certificate profile in RFC 5280 [i.30]. + +The M-Plane Certificate Management Framework in O-RAN Management Plane Specification [i.3] references Clause 9 of 3GPP TS 33.310 [i.2] where CMPv2 is used by “base stations to obtain an operator-signed certificate using a secured communication based on the vendor-signed certificate in the base station and a vendor root certificate pre-installed in the CA/RA server.” + +The M-Plane Certificate Management Framework in O-RAN Management Plane Specification [i.3] also states that “while the approach in [i.2] has been defined for provisioning certificates for use in either IPsec or TLS, the same techniques defined for provisioning TLS certificates are specified to be re-used to provision certificates for use in securing the SSHv2 based M-Plane connection as specified in RFC 6187 [i.4]. Hence, the TLS client CA is responsible for issuing certificates to NETCONF clients, irrespective of whether NETCONF is secured using TLS or SSHv2. Similarly, the TLS server CA is responsible for issuing certificates to NETCONF servers, irrespective of whether NETCONF is secured using TLS or SSHv2.” + +## 3.2 Architecture Assumptions + +### 3.2.1 Use Case for Physical Network Functions + +Figure 3-1 shows a general deployment architecture for certificate enrolment of a physical NF by an operator PKI. This general deployment architecture is generalized from clause 9 of 3GPP 33.310 [i.2]. + +![Figure 3-1: Logical Architecture of O-RAN system: Overview of the security architecture. The diagram shows the interaction between RA/CA, NF B, and NF. RA/CA is connected to NF via CMPv2. NF B is connected to NF via a Secure protocol. Various certificates are pre-installed or used in the security association.](079e02d5b09a646342bbfb2ea862fa81_img.jpg) + +``` + +graph TD + RA_CA[RA/CA] -- CMPv2 --> NF[NF] + NF_B[NF B] -- "Secure protocol" --> NF + VendorRoot[Vendor root certificate is pre-installed.] --> RA_CA + NF_Cert[Enrolled NF certificate is used in the security association.] --> NF_B + VendorSigned[Vendor-signed certificate of NF public key is pre-installed.] --> NF + NF_Operator[The NF obtains the operator-signed certificate on its own public key from RA/CA using CMPv2.] --> NF + +``` + +Figure 3-1: Logical Architecture of O-RAN system: Overview of the security architecture. The diagram shows the interaction between RA/CA, NF B, and NF. RA/CA is connected to NF via CMPv2. NF B is connected to NF via a Secure protocol. Various certificates are pre-installed or used in the security association. + +Figure 3-1: Logical Architecture of O-RAN system: Overview of the security architecture + +The NF is pre-provisioned with a public-private key pair by the vendor, and has the vendor-signed certificate of its public key pre-installed. + +An operator may deploy an RA/CA to replace the vendor-provisioned certificates with operator provided certificates. The operator CA may be deployed using one of the following: + +- either a stand-alone CA implementing a CMPv2 server, or +- a CA having delegated certain tasks to an RA, which is operating the CMPv2 server. + +On initial contact to the operator network the NF establishes a communication channel to the RA/CA of the operator. Using CMPv2 [i.5] a request for a certificate is sent to the RA/CA. The network authenticates the messages from the NF based on the vendor-signed certificate of the NF and the vendor root certificate pre-installed in the network. The NF shall check the integrity protection on the messages from the RA/CA based on the operator root certificate provisioned in the NF. In a response message the NF receives the operator-signed certificate. During the execution of the CMPv2 protocol the NF has to successfully provide a Proof of Possession of the private key associated to the public key to be certified. + +The operator root certificate may be provisioned in the NF prior to or during the CMPv2 protocol run. The protection of the operator root certificate during provisioning may be decided by operator security policy. If an operator root certificate provisioned prior to the CMPv2 protocol run is available, the NF shall use it. Otherwise, the NF shall use the operator root certificate provisioned during the CMPv2 run. If no operator root certificate is provisioned at all then the NF shall abort the procedure. + +After enrolment has been performed, the NF can use the operator-signed certificate to authenticate itself to the NF B of the operator, which is pre-installed with the operator root certificate. The NF then authenticates the NF B using the operator root certificate. + +If at later stage of NF deployment the operator wants to renew the NF certificate, the same procedure will be executed with the old operator-signed certificate of the NF taking the place of the vendor-signed certificate in the initial enrolment. + +# 4 Key Issues + +## 4.1 Key Issue #1: Considering RA and CA as separate logical entities + +### 4.1.1 General Description + +Given the system requirements for O-RAN, it's essential to recognize the Registration Authority (RA) and Certificate Authority (CA) as individual logical units. Some implementations might integrate both within the same network, while others could opt for separate networks, possibly utilizing third-party CAs. As highlighted in RFC4210 [i.5] Appendix A, the justification for an RA's presence can be categorized into technical and organizational reasons. Technically, not all end entities have the necessary hardware for token initialization, making it beneficial for the RA to have this capability, which could also be driven by policy considerations. Moreover, certain entities might not be equipped to issue certificates, underscoring the RA's potential role in this aspect. Organizationally, centralizing tasks within the RA might be more cost-effective, especially when there's a need for specialized token initialization equipment. By incorporating RAs, organizations might also reduce the number of CAs they require. RAs are often better positioned to link individuals with their digital identifiers, especially when the CA is located at a considerable distance from the end entity. It's also worth noting that many setups already possess an administrative structure, simplifying the process of identifying suitable RA candidates, a convenience that might not always extend to CAs. + +NOTE: For example, in WG11, the work-item for Near-RT RIC discusses the security procedure for xApp registration, where Near-RT RIC can also act as RA for xApps. + +### 4.1.2 Security Threats + +**Single Point of Compromise:** Combining RA and CA functions into one entity creates a single point of compromise. If an attacker gains access to this combined entity, they can both verify (as the RA) and issue (as the CA) certificates, leading to a complete breakdown of the trust model. + +**Operational Complexity:** Merging or intertwining the roles of RA and CA can lead to operational challenges, increasing the risk of human errors or misconfigurations. + +**Lack of Role Segregation:** Combining roles goes against the principle of least privilege, where entities should only have the minimum access required to perform their tasks. Misuse or abuse of privileges becomes a significant concern, especially if internal actors become malicious. + +**Backup and Recovery Risks:** A combined system means there's more data to backup and recover, complicating these processes. This may cause data loss or prolonged downtimes can occur if backup or recovery fails. + +**Policy Overlaps:** There might be policy overlaps or contradictions when RA and CA are combined. For instance, the policy for verifying an entity's identity (RA function) might conflict with the policy for issuing a certificate (CA function). + +## 4.2 Key Issue #2: Usage of PSK/Refnum for Initial Certificate Enrolment of PNFs + +### 4.2.1 General Description + +Using PSK/Refnum as a method for the Initial Certificate Enrolment of PNFs is an approach that might be essential for ensuring backward compatibility. However, this method of Certificate Management could necessitate manual interventions, thereby introducing potential vulnerabilities. To mitigate these risks, there's a need for supporting solutions that can seamlessly automate the PSK/Refnum based Certificate Enrolment process. + +### 4.2.2 Security Threats + +**Manual Intervention Risks:** Relying on manual steps for certificate enrolment can lead to human errors, misconfigurations, or oversights, which can compromise the security of the system. Incorrect certificate enrolments, unauthorized access, or even system downtimes can result from these errors, compromising the security and reliability of the O-RAN system. + +## 4.3 Key Issue #3: Usage of Vendor Certificates for Initial Certificate Enrolment of PNFs + +### 4.3.1 General Description + +The use of Vendor Certificates for the initial registration and certificate enrolment is outlined in 3GPP TS 33.310 [i.2] clause 9 “Certificate Enrolment for base stations”. + +This approach facilitates automated Certificate Enrolment, streamlining the integration of new PNFs with a plug-and-play model. + +### 4.3.2 Security Threats + +**Vendor Trustworthiness:** Relying on vendor certificates necessitates a high level of trust in the vendor's security practices and certificate management. If a vendor's security practices are lax, it could lead to the issuance of compromised or weak certificates. + +**Single Point of Failure:** If many PNFs rely on a single vendor's certificate for enrolment, it becomes a single point of failure. Compromise of the vendor certificate can jeopardize the security of all associated PNFs. + +## 4.4 Key Issue #4: Void + +Void + +## 4.5 Key Issue #5: Void + +Void + +## 4.6 Key Issue #6: Initial Certificate Enrolment for new NFs + +### 4.6.1 General Description + +For the seamless integration of new NFs into the network, there's a need for an automated procedure to obtain CA-signed certificates. This process should ensure a pre-established trust relationship with the Registration Authority (RA). + +### 4.6.2 Security Threats + +**Certificate Mismanagement:** If the procedure for obtaining CA-signed certificates isn't robust or secure, there's a risk of certificate mismanagement, misuse, or fraud. This may cause impersonation of legitimate NFs and/or network breaches. + +**Lack of Automation:** Manual processes for NF certificate enrolment can introduce human errors, inconsistencies, or delays. This may cause misconfigurations and/or operational inefficiencies. + +**Interception of Initial Communication:** The initial communication between the NF and the network during the enrolment phase could be intercepted if not securely encrypted. This may cause eavesdropping, data interception, or man-in-the-middle attacks. + +**Inadequate Revocation Mechanisms:** If a NF is compromised or needs replacement, there should be a swift mechanism to revoke its certificate. Ongoing risks arise from breached NFs if certificate revocation is either delayed or not executed properly. + +## 4.7 Key Issue #7: Void + +Void + +## 4.8 Key Issue #8: Vendor Root CA Certificate Renewal + +### 4.8.1 General Description + +When a Vendor's Root CA certificate approaches its expiration date, it's imperative for the Registration Authority (RA) to automatically renew the trust through the certificate management protocol. This proactive approach is essential to guarantee uninterrupted system availability. + +### 4.8.2 Security Threats + +**Expired Certificate Usage:** If the Vendor's Root CA certificate expires without renewal, any NF relying on it could face authentication failures. This may cause system disruptions and/or declined connections. + +**Dependency on Vendor:** The renewal process might depend on the vendor's responsiveness and their certificate issuance protocols. This may cause delays in certificate issuance and vulnerabilities in vendor-provided certificates. + +**Manual Renewal Process:** Relying on a manual process for the renewal of the Vendor Root CA Certificate introduces several challenges. Manual processes inherently increase the risk of oversight, delays, and human error. Without automation, there's a higher likelihood that the certificate might expire before renewal, especially if the impending expiration goes unnoticed or if there are delays in the manual renewal procedure. + +## 4.9 Key Issue #9: Void + +Void + +## 4.10 Key Issue #10: Procedure for Certificate Updates when revoked certificates are detected by NFs + +### 4.10.1 General Description + +During the establishment of TLS or IPsec, an NF might detect revoked certificates. A clear and efficient procedure is essential to update such certificates to ensure the confidentiality and integrity of communications. + +### 4.10.2 Security Threats + +**Continued Use of Revoked Certificates:** Without a prompt update procedure, NFs might continue using revoked certificates, leading to insecure communications. + +**Delay in Certificate Replacement:** If the procedure for updating revoked certificates isn't efficient, there could be significant delays in replacing them. This may cause extended periods of vulnerability, potential NF disruptions, and declined connections. + +**Lack of Automation:** Manual processes for updating revoked certificates can introduce human errors, inconsistencies, or delays. This may cause misconfigurations and/or operational inefficiencies. + +**Inadequate Monitoring:** Without continuous monitoring, revoked certificates might go undetected or unaddressed for extended periods. + +**Ineffective Revocation Lists:** If Certificate Revocation Lists (CRLs) or Online Certificate Status Protocol (OCSP) servers are not updated promptly or are inaccessible, NFs might not detect revoked certificates in time. This may cause continued use of compromised certificates and unauthorized access. + +## 4.11 Key Issue #11: Void + +Void + +## 4.12 Key Issue #12: Certificate to name mapping + +### 4.12.1 General Description + +The Certificate-to-name mapping system is a critical component in the authorisation process. It can lead to a breakdown in the trust model of the O-RAN system. Unauthorized access, especially if mapped to high-privilege names, can compromise the integrity and availability of the O-RAN system. + +### 4.12.2 Security Threats + +**Mapping Database Compromise:** If an attacker gains access to the system or database where the Certificate-to-name mappings are stored, they can alter these mappings. For instance, they might map their own certificate to a high-privilege username. + +#### **Certificate Manipulation and spoofed authentication:** + +The integrity and authenticity of certificates, pivotal in secure communications and authorisation within the O-RAN network, can be jeopardized through certificate manipulation and spoofed authentication. These threats can be notably exploited when the cipher used for signing the certificate lacks integrity assurance or when the TLS server is misconfigured, leading to inadequate validation of certificate signatures. This threat can be exploited under the following two cases: + +- Exploitation through cipher integrity: + - Attackers may alter or create certificates, manipulating identity information, and if the cipher lacks integrity, the system might accept these as valid, granting unauthorized access or privileges. +- Exploitation through TLS misconfiguration: + - A TLS server that doesn't validate certificate signatures accurately may accept manipulated or spoofed certificates, providing attackers unauthorized access based on misrepresented identity information. + +The system, whether due to cipher integrity issues or TLS misconfigurations, may erroneously trust the manipulated or spoofed certificate, mapping it to a high-privilege username or granting unauthorized access and privileges. + +Attackers, once authenticated, can perform unauthorized activities, such as data theft, network misconfigurations, or other malicious actions, under the guise of a legitimate entity. + +## 4.13 Key Issue #13: System overload due to bulk certificate updates + +### 4.13.1 General Description + +When huge number of PNFs / VNFs need to update certificates, the system and communication networks may be overloaded. + +If a huge number of network functions and/or services simultaneously require certificate updates (due to same expiry date, or, due to a common CA certificate revocation, or any other reason), it is possible that all of them trigger the certificate management procedures at the same time. + +- Operators may want to frequently renew the certificates in order to mitigate any security risks involved with using the certificates for longer durations. + - If, for example, a certain crypto algorithm is declared as compromised, it is likely that a huge number of network functions (physical and virtual) need to update their certificates. +- In scenarios when certificates are revoked, in order to avoid any security threats, it is desirable to update and use new certificates as soon as possible. + - According to RFC 4210 [i.5](sections 5.3.13 and 5.3.15), CA may announce revocation of certificates. It is likely that such revoked certificates affect many NFs simultaneously. + - When a new certificate needs to be used, existing secure connections (IPsec/TLS) need to be terminated. This may lead to intermittent unavailability of networks. +- For systems using certificates as authentication mechanisms for man-to-machine communications, the number of certificates will be directly proportional to the number of users. This could mean a large number of certificates, and maybe a need to update all of them together. + +Automated certificate management facilitates the need for minimum manual intervention; however, this can lead to a congestion or overload in the system in scenarios when bulk certificate updates happening simultaneously. Such system overload may lead to un-intentional Denial-of-Services. In scenarios when multiple NF instances catering to specific network slices, the affected network slices may not be dimensioned to accommodate such overload due to bulk certificate updates. + +### 4.13.2 Security Threats + +**System Overload:** When a large number of PNFs/VNFs simultaneously trigger certificate management procedures, it can cause significant strain on the system, potentially leading to slowdowns or outages. + +**Communication Network Congestion:** The simultaneous update of certificates can lead to a surge in network traffic, causing congestion in communication networks. + +**Potential Denial of Service (DoS):** Automated bulk certificate updates, especially if not properly managed or throttled, can unintentionally result in a DoS condition, making services unavailable to legitimate O-RAN NFs. + +**Intermittent Network Unavailability:** When secure connections (like IPsec/TLS) need to be terminated to update certificates, it can lead to temporary network disruptions. + +**Crypto Algorithm Compromise:** If a cryptographic algorithm is declared compromised, a vast number of network functions might need immediate certificate updates, exacerbating the overload issue. + +**Certificate Revocation Risks:** The revocation of certificates, especially if affecting many network functions simultaneously, can lead to widespread disruptions if not managed properly. + +**Delay in Addressing Security Threats:** While operators might want to renew certificates frequently to mitigate risks, the potential system overload can delay these updates, leaving the system vulnerable for longer durations. + +**Man-to-Machine Authentication Risks:** For O-RAN systems with a large number of users using certificates for authentication, simultaneous updates can lead to widespread authentication failures or delays. + +**Operational Complexity:** Managing and coordinating certificate updates for a vast number of PNFs/VNFs can be operationally complex, increasing the risk of errors or misconfigurations. + +## 4.14 Key Issue #14: Void + +Void + +## 4.15 Key Issue #15: Void + +Void + +## 4.16 Key Issue #16: Void + +Void + +## 4.17 Key Issue #17: Void + +Void + +## 4.18 Key Issue #18: Allow Flexibility in the Number of Operator Certificates Associated with each end entity / Interface + +### 4.18.1 General Description + +This key issue addresses the procedure for certificate management when one network function in O-RAN (PNF/VNF/CNF) has several functionalities and several logical interfaces, thus one network function may have several identities for different functionalities and different communication interfaces [ETSI GR NFV-SEC005 V1.2.1 [i.11]]. + +### 4.18.2 Security Threats + +**Multiple Certificate Tracking:** With multiple certificates per network function, tracking, renewing, and revoking certificates becomes more complex. This complexity can lead to mismanagement or oversight, potentially leaving expired or compromised certificates in use. + +**Multiple Points of Compromise:** Each certificate represents a potential point of compromise. With multiple certificates per network function, the attack surface increases, offering more opportunities for attackers to target or exploit a specific certificate. + +**Ambiguous Authorization:** With multiple identities for a single network function, there's a risk of confusion in determining which certificate grants what level of access or functionality. This can lead to unintentional over-privilege or under-privilege in access controls. + +**Granular Revocation:** If one certificate associated with a network function is compromised, determining whether to revoke only that certificate or all associated certificates can be challenging. Incorrect decisions can either leave vulnerabilities open or disrupt legitimate functionalities. + +**Authentication overhead due to multiple certificates:** Engaging in multiple authentications across various interactions due to the management of numerous certificates for a network function interacting with different interfaces or systems, which could inadvertently introduce cumulative latency and operational delays in the network communication and data transmission processes. + +**Varied Certificate Handling:** Different vendors might handle multiple certificates differently, leading to potential integration or interoperability challenges in a multi-vendor O-RAN environment. + +**Bulk Operations Vulnerabilities:** Automated systems managing multiple certificates might inadvertently expose them to risks during bulk operations, like simultaneous renewals or updates, potentially leading to system overloads or misconfigurations. + +## 4.19 Key Issue #19: Certificate Management in Distributed Cluster Processing + +### 4.19.1 General Description + +VNF and CNF components terminating interfaces that use X.509 certificates for authentication can be scaled across multiple instances on a single host and across multiple hosts. This distributed nature poses unique challenges for certificate management. + +The certificate management framework must support these architectural patterns. It's imperative to ensure that as VNFs and CNFs scale, the associated certificates are managed securely and efficiently. + +Adherence to best practices is crucial: + +- Each VNF or CNF instance should ideally have its unique certificate. This not only ensures individualized authentication but also limits the potential security impact should any single instance be compromised. +- In environments like Kubernetes, controlling the traffic flow into and out of the cluster is vital. Assigning certificates to the ingress or egress points provides a layer of authenticated security. + +Furthermore, as deployments expand to support geographic redundancy, the certificate management system should be capable of maintaining consistent security protocols across all NF instances, irrespective of their location. + +### 4.19.2 Security Threats + +**Certificate Management Mistakes:** As VNF and CNF components scale across multiple instances and hosts, the sheer number of certificates to manage can become overwhelming, leading to potential mismanagement or oversight. + +**Varying Certificate Assignments:** Different architectural patterns might lead to inconsistencies in how certificates are assigned, renewed, or revoked, potentially leaving vulnerabilities open or causing operational disruptions. + +**Single Point of Failure:** If one instance of a VNF or CNF is compromised, and best practices like unique certificates for unique instances aren't followed, attackers might gain unauthorized access to other instances or components. + +**Cluster Entry and Exit Points (Ingress/Egress Vulnerabilities):** Assigning a certificate to the ingress or egress point in a Kubernetes cluster can create a choke point. If this certificate is compromised, it can jeopardize the security of the entire cluster. + +**Geographic Redundancy Concerns (Synchronization Issues):** Deployments that support geographic redundancy might face challenges in synchronizing certificate updates, renewals, or revocations across geographically distributed instances, leading to potential inconsistencies or vulnerabilities. + +**Automated Scaling Risks:** In environments where instances are dynamically created or destroyed based on demand, ensuring that each instance has a valid, uncompromised certificate becomes challenging. There's a risk of instances being spun up with outdated or vulnerable certificates. + +**Interoperability and Integration Issues:** Different VNF and CNF components, especially from different vendors or in different architectural patterns, might handle certificates differently, leading to potential integration challenges or security gaps. + +**Revocation and Renewal Challenges:** With distributed clusters, determining which certificate to renew or revoke, especially in the event of a compromise, becomes complex. Incorrect decisions can disrupt legitimate services or leave vulnerabilities open. + +## 4.20 Key Issue #20: Certificate Management and Secure Storage of Application Private Keys + +### 4.20.1 General Description + +Secure distribution and storage of Application certificates and private keys is critical to the effective use of certificates for authentication and confidentiality. The certificate management framework should include recommendations for secure storage of Applications private keys. + +### 4.20.2 Security Threats + +**Storage compromise:** Without secure storage solutions like vaults where keys are stored can be breached, leading to the exposure of sensitive cryptographic material and the compromising the entire authentication mechanism. + +**Man-in-the-Middle attacks:** Transmitting private keys over networks, if not done securely, can expose them to interception, leading to potential man-in-the-middle attacks. + +**Physical access to storage:** If the environment isn't resistant to physical breaches, adversaries could gain physical access to the storage medium, leading to potential data theft or tampering. + +**Lack of key rotation:** If the certificate management framework doesn't provide clear guidelines on key rotation, outdated or potentially compromised keys might continue in use. + +**Regulatory violations:** Inadequate protection of cryptographic material can lead to violations of data protection regulations, resulting in penalties and reputational damage. + +**Management challenges (Multiple NF instances):** As the number of NF instances grows, ensuring that each instance securely generates and stores its private keys becomes operationally complex. + +## 4.21 Key Issue #21: Coordinating Certificate Management with VNF/CNF Lifecycle Activities + +### 4.21.1 General Description + +The lifecycle activities of VNF/CNF are not always synchronized with the validity periods of their associated certificates. As these components evolve, undergo updates, or are replaced, it's crucial to ensure that their certificate management remains consistent and secure. Several scenarios highlight the importance of this coordination: + +**Updating a VNF/CNF to a new version:** When updating or replacing a VNF/CNF, the handling of certificates becomes paramount. The updated component must maintain the same level of trust and authentication capabilities as its predecessor. + +**Certificates stored in a vault or persistent storage:** If certificates are stored in a secure vault or other persistent storage solutions, a recreated or updated VNF/CNF should be able to access these without compromising security. The process for granting this access, especially in the context of updates or replacements, needs clear definition and robust security measures. + +**Certificates embedded within the VNF/CNF:** For VNFs that store certificates internally, software component updates should not disrupt the availability or integrity of these certificates. It's essential to ensure that updates are seamless, without inadvertently affecting the stored certificates. + +**Certificates managed by Kubernetes:** In environments where Kubernetes manages CNF containers and their certificates, updating or replacing CNF containers should not impact the availability or validity of the associated certificates. The orchestration platform must ensure that new container versions inherit the necessary certificates without security lapses. + +### 4.21.2 Security Threats + +**Misalignment of certificate validity and component lifecycle (Expired certificates):** If the lifecycle of a VNF/CNF extends beyond the validity of its certificate, it might continue to operate with an expired certificate, leading to authentication failures or reduced trust. + +**Inconsistent certificate management during updates (Loss of trust):** If an updated VNF/CNF doesn't maintain the same certificate or trust level as its predecessor, it can lead to trust breakdowns in the network, causing operational disruptions. + +**Compromised certificate storage (Unauthorized access):** If the process of granting access to certificates in a vault or persistent storage isn't secure or if insecure vaults or storage solutions are used, malicious entities might gain unauthorized access to sensitive certificate data. + +**Software update overwrites and loss of certificate integrity:** Updates to VNF/CNF components might inadvertently overwrite or corrupt internally stored certificates making them unusable or less secure, leading to potential authentication issues. + +**Management overhead:** Coordinating certificate management with VNF/CNF lifecycle activities can increase operational complexity, leading to potential mismanagement or oversight. + +## 4.22 Key Issue #22: Supporting Public and Private Certificate Authorities (CA) + +### 4.22.1 General Description + +To cater to the varied needs of different O-RAN network components and to offer flexibility in security configurations, the certificate management framework must be adept at managing a range of certificates. This includes client/server certificates, which facilitate secure interactions between O-RAN network entities, as well as intermediate certificates that form the chain of trust, and root certificates that anchor this trust. + +Furthermore, the origin of these certificates can vary. They might be issued by public CAs, which are globally recognized and trusted entities, or by private CAs, which are often tailored for specific organizational or network needs. The O-RAN certificate management framework must seamlessly support and manage certificates from both these sources, ensuring that regardless of the CA's nature, the security and integrity of the O-RAN network remain uncompromised. + +### 4.22.2 Security Threats + +**Mismanagement of multiple certificate sources:** Managing certificates from both public and private CAs can lead to inconsistencies in how certificates are validated, renewed, or revoked, potentially leaving vulnerabilities open or causing operational disruptions. + +**Intermediate certificate compromise:** If an intermediate certificate is compromised, it can undermine the trust of any certificate issued under it. + +**Root certificate exposure:** The exposure or compromise of a root certificate can jeopardize the entire trust chain. + +**Private CA - Insufficient validation:** Private CAs, especially if not properly managed, might issue certificates without rigorous validation, leading to potential security risks. + +**Private CA - Limited revocation capabilities:** Private CAs might not have the same robust infrastructure as public CAs for certificate revocation, leading to delays in revoking compromised certificates. + +**Public CA - Global exposure:** Certificates from public CAs, being globally recognized, can be a target for attackers, leading to potential large-scale attacks or exposures. + +**Public CA - Third-party risks:** Relying on external public CAs introduces third-party risks, where the compromise or mismanagement of the CA can impact the O-RAN network. + +**Management overhead:** Coordinating certificate management from multiple sources (public and private CAs) can increase operational complexity, leading to potential mismanagement or oversight. + +**Varied certificate standards:** Different CAs, especially across public and private domains, might have varied certificate standards or formats, leading to potential integration/interoperability challenges or security gaps. + +**Regulatory violations:** Inadequate management or validation of certificates, especially from private CAs, can lead to violations of data protection or security regulations, resulting in penalties and reputational damage. + +## 4.23 Key Issue #23: Distribution of Intermediate and Root Certificates + +### 4.23.1 General Description + +The management and distribution of intermediate and root certificates forms the backbone of the certificate trust chain. The O-RAN certificate management framework must be equipped with the capabilities that automate these processes. Specifically: + +- Operators should have an automated mechanism to request both intermediate and root certificates from the Certificate Authorities (CA) responsible for issuing the deployment's certificates. This ensures timely and efficient acquisition of these critical trust anchors. +- Once acquired, there should be a straightforward method to load these certificates into the key stores of the various network components, be it PNF, VNF, or CNF. This ensures that every component in the network is aligned with the trust framework and can validate communications effectively. + +### 4.23.2 Security Threats + +**Incomplete trust chain:** If intermediate or root certificates are not properly distributed or loaded, it can result in an incomplete or broken trust chain, leading to authentication failures or reduced trust. + +**Unauthorized access during distribution:** If the distribution process isn't secure, certificates could be intercepted and potentially altered or replaced with malicious ones during transit. + +**Exposure during Request:** An automated request mechanism that isn't properly secured can expose sensitive details or allow unauthorized entities to request certificates. + +**Outdated certificates:** If the distribution process isn't timely, network components might operate with outdated intermediate or root certificates, leading to potential security risks. + +**Misconfigurations:** Automated processes, if not properly configured, can lead to errors such as loading the wrong certificates or loading them into incorrect locations. + +**CA compromise:** If the CA responsible for issuing certificates is compromised, it can lead to the distribution of malicious or unauthorized certificates. + +**Regulatory violations:** Inadequate management or distribution of certificates can lead to violations of data protection or security regulations, resulting in penalties and reputational damage. + +## 4.24 Key Issue #24: CMPv2 Message Minimal Set and Robustness + +### 4.24.1 General Description + +The O-RAN certificate management framework must clearly define the specific CMPv2 message set that will be supported. This not only standardizes the communication for certificate operations but also ensures that the network components have a consistent and robust protocol to rely on for certificate-related interactions. By specifying this minimal set, the framework aims to streamline certificate management processes, reduce ambiguities, and bolster the overall security and efficiency of the O-RAN network (3GPP TS 33.310 [i.2] clause 9.5 has a CMPv2 profile definition). + +### 4.24.2 Security Threats + +**CMPv2 Exploits:** If the CMPv2 protocol or its implementation has vulnerabilities, attackers could exploit these to compromise certificate operations or gain unauthorized access. + +**Inconsistent message handling:** Without a clearly defined message set, different network components might handle CMPv2 messages inconsistently, leading to potential security gaps or operational disruptions. + +**Ambiguities in message processing:** Without a clear and minimal set of supported messages, there could be ambiguities in how messages are processed, leading to potential errors or security risks. + +## 4.25 Key Issue #25: RA and CA Capacity Estimation, Renewal Intervals and Credential Strength + +### 4.25.1 General Description + +In the evolving landscape of O-RAN networks, the strength and validity of cryptographic credentials play a pivotal role in ensuring secure communications. Adhering to best practices, the current recommendations emphasize: + +- Validity periods: Certificates should have validity periods that don't exceed one year. This ensures that credentials are regularly updated, reducing the window of vulnerability, and aligning with the dynamic nature of network environments. +- Elliptical Curve Cryptography (ECC): When leveraging ECC algorithms, it's advised to use key lengths of three hundred eighty-four (384) bits. This strikes a balance between computational efficiency and security, providing robust protection against potential cryptographic attacks. +- Diffie-Hellman Cryptography: For systems employing Diffie-Hellman cryptographic algorithms, key lengths should be set to a minimum of two thousand and forty-eight (2048) bits. This ensures a high level of security, making it computationally challenging for adversaries to compromise the encryption. + +### 4.25.2 Security Threats + +#### Certificate expiry and renewal: + +- If certificates expire without timely renewal, it can lead to authentication failures or communication breakdowns. +- Longer validity periods can provide attackers with a more extended window to exploit potential vulnerabilities associated with a certificate. + +**Brute Force attacks:** Insufficient key lengths can make cryptographic algorithms susceptible to brute force attacks. + +**Cryptographic vulnerabilities:** As cryptographic research progresses, older algorithms or shorter key lengths might be found vulnerable. If not updated, they can be exploited. + +**ECC - Weak Curves:** Not all elliptical curves provide the same security level. Using weak or compromised curves can lead to reduced security. + +**DH - Man-in-the-Middle attacks:** Without proper authentication or with shorter key lengths, Diffie-Hellman can be vulnerable to man-in-the-middle attacks. + +**Logjam Attack:** If not properly configured, Diffie-Hellman is susceptible to the Logjam attack, where attackers can downgrade to vulnerable TLS connections. + +**Performance overhead:** While longer key lengths provide better security, they also come with a performance overhead, potentially affecting network efficiency. + +## 4.26 Key Issue #26: Namespace Conventions + +### 4.26.1 General Description + +The certificate management framework should develop common namespace template examples (Cert Subject/SANs) to facilitate rapid integration with multiple vendor products and enable cross operator integration. + +VendorName and OperatorName should be the only required inputs to generate all namespaces. + +Namespace conventions should only be defined after the other key issues have been addressed. Additionally, it must be determined which entity, the client requesting a certificate or the CMPv2 implementation used by the client, is responsible for specifying each component of a named field, e.g., subject or SAN. + +### 4.26.2 Security Threats + +**Inconsistent namespace use:** If namespace conventions are not consistently used across all certificates, it could lead to integration issues, misconfigurations, or erroneous trust establishment between entities. + +**Integration challenges:** Without standardized namespace conventions, integrating multiple vendor products and enabling cross-operator integration might become cumbersome and error-prone, potentially leading to security loopholes. + +**Impersonation threats:** In the absence of stringent namespace conventions, attackers might exploit the laxity to create certificates that impersonate legitimate entities, thereby gaining unauthorized access and compromising secure communications. + +## 4.27 Key issue #27: Handling of certificate revocation in O-RAN + +### 4.27.1 General Description + +Certificates revocation procedures are a critical part of the overall certificate lifecycle management. Every certificate has a finite validity period, during which the certificate is expected to be in use. However, prior to the expiration of the validity period, the Certification Authority (CA) may declare that a certificate that it issued can no longer be trusted due to multiple circumstances including suspected compromise of the private key. + +How do we handle certificate revocation in O-RAN elements? Certificate validation requires access to revocation information, either in the form of a Certificate Revocation Lists (CRL) or an Online Certificate Status Protocol (OCSP) response. OCSP Responses are often included in a TLS handshake; this practice is called OCSP stapling. + +RFC 5280 [i.30] defines a CRL as ‘a time-stamped list identifying revoked certificates that is signed by a CA or CRL issuer and made freely available in a public repository’. The method involves each CA/CRL issuer periodically issuing + +such list, in order to communicate the revocation status of the affected certificates. When a client wants to retrieve a CRL for a particular certificate, it retrieves it from a specified CRL Distribution Point (CRLDP) that is carried in the certificate itself. Typically, HTTP is used to fetch the CRL, and the locations supporting the download of the CRL are chosen to reduce the inherent latency of the procedure. + +OCSP, defined in RFC 6960 [i.26], is ‘a protocol useful in determining the current status of a digital certificate without requiring CRLs’. It can be used in addition to or instead of CRLs. OCSP is often faster than CRL checking process. With OCSP stapling (refer to RFC 6066 [i.17]) the OCSP Response is fetched by the TLS server before the handshake, and then it is transported together with the certificate (“stapled”) during the handshake. OCSP stapling reduces latency and increases availability of the revocation information, hiding any OCSP Responder outages, even very short ones. + +When a CA has revoked, or it is about to revoke, a particular certificate, it may issue an announcement for revocation, to enable the automated re-enrolment; see Section 5.3.15 of RFC 4210 [i.5]). + +In some situations, an RA can detect revoked Vendor / Service Provider’s CA certificates. The RA should be able to issue signed revocation requests on behalf of end entities associated with it, whereas the end entity may not be able to do this itself, especially if access to the private key has been lost. This could be a use case to study, i.e., who and under what circumstances should/can sign the revocation request that will be accepted by the CA. + +As part of the PNF/VNF/CNF lifecycle management procedures certificates associated with a decommissioned PNF/VNF/CNF should no longer be useable, therefore the decommissioning process must include a certificate revocation request to the issuing CA. + +### 4.27.2 Security Threats + +**Mismanagement of revocation requests:** Ineffective handling or communication breakdowns regarding revocation requests could lead to compromised certificates remaining active. This allows for the potential misuse of compromised certificates, endangering secure communications and data integrity. + +**Ineffective decommissioning:** If certificates of decommissioned PNF/VNF/CNF are not revoked effectively, they might be misused. This could lead to unauthorized activities, such as data breaches or network intrusions, under the guise of decommissioned entities. + +**OCSP responder outages:** Dependency on OCSP responders for certificate validation could be risky in the event of outages. This could hinder the ability to validate certificate statuses, potentially disrupting secure communications. + +**Compromised certificate continuance:** If a compromised certificate is not promptly revoked and announced, it may continue to be used maliciously. This could enable attackers to impersonate legitimate entities, decrypt secure communications, or inject malicious content. + +**Incomplete revocation dissemination:** In some instances, revocation information may not be disseminated to all relevant entities in the network. This could lead to some entities continuing to trust a revoked certificate, posing security risks. + +## 4.28 Key issue #28: Risk of Service un-availability due to root CA Certificate updates for CNFs and VNFs + +### 4.28.1 General Description + +CNFs and VNFs use certificates which are signed by intermediate or root CA certificates from operator’s choice of PKI. + +![Figure 4-1: A possible system comprising different applications with different Root Certificates. The diagram shows a 'Kubernetes Platform / Cloud Host Environment' at the bottom, which contains two 'Root CA' boxes: 'Root CA1' and 'Root CA2'. Above 'Root CA1' is a dashed box labeled 'Application Group 1 (CNFs/VNFs)' containing a yellow box 'Certs Signed by Platform Root CA1'. Above 'Root CA2' is a dashed box labeled 'Application Group 2 (CNFs/VNFs)' containing a blue box 'Certs signed by Platform Root CA2'. Arrows point from 'Root CA1' to its respective cert box and from 'Root CA2' to its respective cert box.](92fadb378b90c725ee5d1144561ed429_img.jpg) + +Figure 4-1: A possible system comprising different applications with different Root Certificates. The diagram shows a 'Kubernetes Platform / Cloud Host Environment' at the bottom, which contains two 'Root CA' boxes: 'Root CA1' and 'Root CA2'. Above 'Root CA1' is a dashed box labeled 'Application Group 1 (CNFs/VNFs)' containing a yellow box 'Certs Signed by Platform Root CA1'. Above 'Root CA2' is a dashed box labeled 'Application Group 2 (CNFs/VNFs)' containing a blue box 'Certs signed by Platform Root CA2'. Arrows point from 'Root CA1' to its respective cert box and from 'Root CA2' to its respective cert box. + +**Figure 4-1: A possible system comprising different applications with different Root Certificates.** + +Figure 4-1 gives a high level view of a possible system where different application groups of CNFs/VNFs may be using different root/sub-CA certificates for signing. + +The root CA / sub-CA certificates used to sign certificates for CNFs and VNFs may need to be updated in the following scenarios: + +- Root / sub CA certificate expiry +- Root/sub CA certificate revocation +- Operator deciding to change the CA for signing + +In general, these scenarios can be referred to as a need for PKI migration. During the PKI migration procedure, all the certificates issued to CNFs / VNFs and signed by these root CA certificates need to be updated with new CA certificates. If such a PKI migration is needed during runtime, when system is already providing services: + +- This can lead to slice / service un-availability +- Some CNFs can be handling UPF functionality +- Some CNFs can be handling various control plane functionalities +- If all CNFs/VNFs catering to a network slice use the same root CA, there is a risk of un-availability of the full slice. + +Partial un-availability of services may still appear as network un-availability for end users. + +### 4.28.2 Security Threats + +**Partial or complete service un-availability:** If intermediate or root CA certificates which are used to sign certificates for CNFs and/or VNFs need to be updated during runtime, it is likely to lead to partial or complete service un-availability. + +**Network slice un-availability:** If all CNFs and/or VNFs of a particular network slice are impacted, it is likely to lead to unavailability of the network slice. + +## 4.29 Key issue #29: Certificate requirements for O-Cloud control plane + +### 4.29.1 General Description + +The O-Cloud control plane acts as a pivotal component in managing and orchestrating cloud resources and services. Ensuring secure communications and operations within the control plane involves: + +- Establishing a dedicated CA for the O-Cloud control plane to isolate and protect the certificate issuance and management processes specific to control plane components. +- Enforcing the use of TLS for all communications within the control plane components to ensure that data in transit is encrypted and authenticated, safeguarding it from unauthorized access and manipulation. + +### 4.29.2 Security Threats + +**Cross-domain security breaches in unified CA environments:** In a multi-domain (plane) environment, a security breach in one domain might cascade to others, especially if a common CA is used for certificate issuance across all domains. + +**CA Compromise:** If a CA is compromised, all certificates issued by it, across all domains, are potentially untrustworthy, leading to widespread network vulnerability. + +**Policy misalignment in Shared CA Environments:** Shared CAs might necessitate generalized policies that may not align with the specific security and operational needs of the control plane. + +## 4.30 Key issue #30: Certificate management for cloud deployment models + +### 4.30.1 General Description + +Addressing the intricacies of certificate management is pivotal, especially when considering varied O-Cloud deployment models, namely private cloud, community cloud, public cloud, and hybrid cloud. Each deployment model presents unique challenges and requirements in terms of certificate issuance, renewal, and revocation, which necessitates a tailored approach to ensure secure and efficient operations. + +### 4.30.2 Security Threats + +**Unauthorized access in multi-tenancy environments:** Public clouds often involve multi-tenancy, where multiple users or entities share the same resources. If certificate management is not meticulously handled, one tenant might unintentionally gain access to another tenant's data or services, leading to potential data leakage, unauthorized data manipulation, or other security incidents. + +**Complexity in hybrid cloud certificate coordination:** Hybrid cloud models, which integrate both private and public cloud solutions, necessitate coordinated certificate management to ensure secure data transfer and communication between different environments. Failure to synchronize and securely manage certificates might expose data during transfer, making it susceptible to interception or alteration by malicious entities. + +**Internal trust models:** Private clouds often operate on an internal trust model, where the CA is implicitly trusted by all entities within the organization. Mismanagement in this context can lead to internal threats, where malicious actors within the organization or compromised internal systems exploit the trust placed in the CA to conduct attacks, such as impersonating legitimate services or users. + +**Lack of external audit:** Unlike public CAs, which are often subject to external audits due to their widespread use on the public internet, private CAs might not be subject to the same level of oversight. This lack of external audit can sometimes lead to lax practices or oversights going unnoticed and unaddressed, potentially increasing the risk of mismanagement. + +## 4.31 Key issue #31: Void + +Void + +## 4.32 Key issue #32: Void + +Void + +## 4.33 Key issue #33: Certificate Profiling in O-RAN + +### 4.33.1 General Description + +A certificate profile is basically a template used to specify fields and form of a certificate. The profiles allow to configure a set of parameters, which support the security posture of the system as well as interoperability. 3GPP has specified in TS 33.310 [i.2] on the top of RFC5280 [i.13], several certificate profiles for types of network elements (e.g. Security Gateway (SEG), SBA, etc.), protocol (e.g. TLS entity), CA type (e.g. interconnection, SEG CA, etc.) and procedures (e.g. base station enrolment). This key issue intends to study specific O-RAN certificate profiling requirements across the main network functions of the O-RAN architecture in addition to those specified in RFC5280 and 3GPP, especially for elements and systems expressly defined in O-RAN (e.g. O-RU, Near-RT RIC, Non-RT RIC, etc.). + +Common certificate security parameters are defined in O-RAN Security Protocol specification [i.41], such as hash algorithms, signature algorithms, minimum key lengths, etc. However, certain network functions, sub-systems or protocols used in O-RAN may require specific certificate profiles, including e.g., rules for validity periods, extensions (e.g. subjectAltName, keyUsage, etc.). + +Once the certificate profiles have been defined for O-RAN, the CA(s) serving O-RAN architecture shall check that the requests are matching the pre-defined profiles, as well as the network elements of the O-RAN architecture shall accept only profiled certs for authentication and encryption purposes. + +### 4.33.2 Security Threats + +**Inconsistent security posture:** Without standardized certificate profiles, different elements within the O-RAN system might employ varying security parameters, leading to inconsistencies in the security posture across the network and potentially creating weak links that can be exploited by attackers. + +**Compromised encryption and authentication:** If certificate profiles are not rigorously defined and enforced, certificates that do not adhere to optimal security practices may be used, potentially compromising the encryption and authentication mechanisms within the O-RAN network. + +**Misalignment with external standards:** If O-RAN-specific certificate profiles diverge significantly from established standards (e.g., RFC5280 [i.13], 3GPP TS 33.310 [i.2]), it may introduce complexities and challenges in ensuring alignment and compatibility with external systems and networks. + +**Non-compliance with regulatory requirements:** Certificate profiles that do not align with regulatory or industry-specific requirements for cryptographic standards and data protection may expose the O-RAN network to legal and compliance risks. + +**Vendor-specific vulnerabilities:** If certificate profiles are not standardized and are heavily influenced by vendor-specific implementations, it may introduce vulnerabilities specific to certain products or solutions within the O-RAN system. + +## 4.34 Key issue #34: Void + +Void + +## 4.35 Key issue #35: Void + +Void + +## 4.36 Key issue #36: Certificate sharing or not-sharing in Apps/VNFs/CNFs + +### 4.36.1 General Description + +**Sharing case:** In the virtual environment, the NF is distributed in the virtual environment and there is no physical boundary for internal communication. If the private key has multiple copies, the risk of key disclosure is increased: transferring the private key faces communication attack, and, multiple copy or multiple access means one copy disclosure will pose a threat to all VMs/Containers using that certificate. Therefore, sharing private key and certificate should be actively discouraged unless carefully implemented. + +**Not sharing case:** For this case, multiple certificates for one App/VNF/CNF brings some complexities for management: + +- Complexity in operation and maintenance (e.g. complex to configure the mapping between certificates and VMs/Containers) +- Complexity in updating/revoking a certificate. The CA/RA workload is increased +- Complexity to O-Cloud dynamic orchestration. Each time the VM/Container scales and/or migrates, the certificate is expected to be either initially applied or revoked. The application and revoke are network communication and will lead to time latency for the orchestration. + +### 4.36.2 Security Threats + +#### Threats from Sharing Certificates: + +**Widespread compromise:** A single compromise of a private key that is shared across multiple VMs/Containers can cascade into a network-wide security incident, affecting various applications and services. This could lead to unauthorized access, data breaches, and potential downtimes. + +**Communication interception:** The transmission of private keys across the network can be intercepted by malicious actors, especially if the communication channels are not adequately secured. This interception can facilitate unauthorized access and data manipulation. + +**Unauthorized access:** The availability of multiple copies of a private key increases the vectors through which unauthorized entities might gain access. Unauthorized access can lead to data breaches. + +#### Threats from Not Sharing Certificates: + +**Operational disruptions:** Managing multiple certificates for each App/VNF/CNF can introduce operational challenges, particularly in ensuring that each certificate is correctly configured and mapped. Misconfigurations or erroneous mappings can lead to service disruptions, inaccessible services, and potential non-compliance with regulatory standards. + +**Delayed orchestration:** The necessity to apply or revoke certificates during scaling or migration operations introduces a latency that can impede the swift orchestration of services. This delay can impact the agility of the O-Cloud + +environment, affecting its ability to promptly scale, migrate, or recover services, which is crucial in maintaining service availability and reliability. + +## 4.37 Key issue #37: Lightweight solution + +### 4.37.1 General Description + +The certificate management solution should be lightweight to support low resource devices and reduce the footprint and computational overhead associated with certificate management. Striking a balance between maintaining a robust, secure certificate management system and ensuring that it is not resource-intensive is pivotal to support various applications within the O-Cloud environment. Implementing a lightweight certificate management solution, while beneficial for low-resource applications, can introduce several security threats that need to be meticulously considered and mitigated. + +### 4.37.2 Security Threats + +**Limited security protocols:** Using lightweight solutions may necessitate the use of simplified or less secure cryptographic algorithms and protocols. These might not be equipped to safeguard against advanced persistent threats or sophisticated cyber-attacks, thereby making the system susceptible to unauthorized access and data breaches. + +**Inadequate revocation capabilities:** Efficient certificate revocation is crucial to prevent unauthorized access, especially in cases where a certificate is compromised. Lightweight solutions might struggle to promptly manage revocation processes, thereby extending the vulnerability window. + +**Insufficient audit and logging:** Limited resources might restrict the ability to maintain comprehensive logs and audits, which are crucial for identifying and investigating security incidents and ensuring regulatory compliance. + +## 4.38 Key issue #38: Interoperability + +### 4.38.1 General Description + +The key management solution should be specified in an unambiguous and well-defined manner to allow easy interoperability of implementations. If protocols are underspecified the O-RAN specification should add a profile that fills the gaps. + +### 4.38.2 Security Threats + +**Inconsistent implementation across vendors:** Different vendors might interpret and implement certificate management protocols differently, leading to inconsistencies that could be exploited by malicious actors. This can lead to unauthorized access, data breaches, and disrupted communication between NFs in the O-RAN system. + +**Inconsistent revocation handling:** Varied approaches to managing certificate revocations across implementations could result in the persistent use of revoked certificates within certain NFs of the O-RAN system. Consequently, this might allow malicious or compromised NFs to continue operating within the network, perpetuating ongoing security threats. + +**Inadequate certificate authentication:** Divergent certificate validation methodologies across O-RAN NFs may result in suboptimal verification processes, paving the way for security compromises. Consequently, this may allow unauthorized access and potentially cause data leaks due to the acceptance of invalid or expired certificates. + +## 4.39 Key issue #39: Crypto agility + +### 4.39.1 General Description + +The solution should be easy to extend with new crypto algorithms as the threat landscape changes (eg. post-quantum crypto). + +### 4.39.2 Security Threats + +**Outdated algorithm exploitation:** Persistent use of outdated cryptographic algorithms may expose the O-RAN system to adversaries who have developed capabilities to exploit known vulnerabilities. The exploitation of outdated cryptographic methods could lead to unauthorized access, manipulation of sensitive data, and potential disruption in communication within the O-RAN system. + +**Quantum computing threats:** The advent of quantum computing threatens the security of traditional cryptographic algorithms, which may become obsolete or insecure. The O-RAN system might be susceptible to breaches by quantum-enabled adversaries, leading to unauthorized access and potential data breaches, thereby compromising user privacy and operational data. + +## 4.40 Key issue #40: Void + +Void + +## 4.41 Key Issue #41: CMPv2 + +### 4.41.1 General Description + +Certificate Management Protocol version 2 (CMPv2) is the most commonly supported and used protocol for certificate management in mobile networks. CMPv2 is specified by 3GPP and O-RAN Alliance WG4 for the M-Plane. The lack of specification for CMPv2 in the O-RAN Alliance's Security Protocols Specifications allows a security gap and could impact vendor interoperability. It would be beneficial to the O-RAN community to update the Security Protocols Specifications to include CMPv2. + +### 4.41.2 Security Threats + +**Inconsistent implementation and interoperability issues:** Without a standardized specification for CMPv2, different vendors might implement the protocol in slightly different ways. This inconsistency can lead to vulnerabilities if one vendor's implementation is less secure than another's, to interoperability issues, where systems from different vendors might not communicate seamlessly. + +## 4.42 Key Issue #42: Certificate management for Shared O-RU + +### 4.42.1 General Description + +In a multi-operator shared O-RU environment, diverse certificate policies and practices among operators can lead to inconsistencies in certificate management, challenges in synchronizing updates, and complexities in establishing mutual trust, making coordinated and harmonized operations crucial for security and functionality. + +### 4.42.2 Security Threats + +Different operators might have varying certificate policies, leading to potential inconsistencies in certificate issuance, renewal, and revocation. + +Coordinating certificate issuance, renewal, and revocation across multiple operators for a shared O-RU can introduce complexities and potential inconsistencies. + +If a certificate or security update is required for the shared O-RU, synchronizing and coordinating this across multiple operators can be challenging. + +Ensuring that all operators trust each other's certificates and establishing mutual trust in a multi-operator environment can be complex. + +## 4.43 Key Issue #43: NF with an expired certificate + +### 4.43.1 General Description + +Initializing an NF with an expired certificate in an O-RAN system not only risks operational disruptions due to failed secure connections with other network components but also heightens vulnerability to impersonation and man-in-the-middle attacks as attackers can exploit the invalid certificate, especially if network entities are lax in certificate validity checks. + +### 4.43.2 Security Threats + +The NF might not be able to establish secure connections with other components of the network, leading to service disruptions. Other entities might reject connections from the NF due to its expired certificate. + +Expired certificates can be a target for attackers. They might exploit the lack of a valid certificate to launch impersonation or man-in-the-middle attacks, especially if other components in the network aren't stringent about checking certificate validity. + +# 5 Solutions + +## 5.1 Solution #1: Automation of PSK/Refnum based Certificate Enrolment + +### 5.1.1 Description + +Zero-touch based automation of PSK/Refnum based Certificate Enrolment can be considered, using robust key (re-) generation and secure key (re-)distribution techniques. + +RFC 4210 [i.5] Section 4.2.2.2 Basic Authenticated Scheme talks about Initial Authentication Key (IAK) and reference value-based Certificate Enrolment. In this Technical Report, IAK is referred to as PSK (Pre-shared Key) and reference value is referred to as Refnum. In order to use this mechanism for initial certificate enrolment for CNF/VNFs in O-RAN, when any CNF / VNF is deployed in an O-Cloud environment, operator provisions and distributes a PSK-Refnum pair to each newly deployed CNF/VNF. + +A Zero-touch automation of PSK/Refnum based Certificate Enrolment can be implemented by the operator, using robust key (re-)generation and secure key (re-)distribution techniques. From security point of view, ensure that the automated provisioning and distribution of PSK/Refnum is secure, and PSK/Refnum are provided only to authenticated and validated CNFs/VNFs. Such automations are implementation specific and follow relevant security mechanisms similar to those followed for distributing other system specific configurations. + +### 5.1.2 Impacts on Existing Interfaces and Functionality + +None. + +### 5.1.3 Solution Evaluation + +The solution proposed here relies on operator's implementation for automated provisioning and distribution of PSK/Refnum. The security mechanisms for such provisioning and distributions can be similar to other system specific configurations and no new standardization relevant aspects are proposed by this solution. + +### 5.1.4 Potential Security Requirements + +Any automated PSK/Refnum generation and distribution systems implemented by the operator should ensure that no rogue CNF/VNF can obtain valid PSK/Refnum values. + +## 5.2 Solution #2: Study the use of BRSKI + +### 5.2.1 Description + +Study the use of BRSKI instead of OR along with CMPv2. This solution partially addresses key issue #41. + +In this study, the possible applicability and use of BRSKI in O-RAN for secure bootstrapping of new devices is described based on the understanding of RFC 8995 [i.28]. + +Bootstrapping Remote Secure Key Infrastructure (BRSKI) protocol provides a solution for secure "zero-touch (automated)" bootstrap of new (unconfigured) devices. + +Following are important aspects to be considered for this. + +- The architecture of BRSKI is relevant for "zero-touch" bootstrapping of devices which are "Drop-Shipped" from different vendors, and their ownership needs to be tracked. + +- Drop-Ship: The physical distribution of equipment containing the “factory default” configuration to a final destination. In zero-touch scenarios, there is no staging or pre-configuration during drop-ship. The “zero-touch” aspect is considered from this drop-shipping perspective. + - As stated in RFC 8995 [i.28], BRSKI “is intended to scale to thousands of devices located in hostile environments, such as ISP-provided Customer Premises Equipment (CPE) devices that are drop-shipped to the end user. The situation where an order is fulfilled from a distributed warehouse from a common stock and shipped directly to the target location at the request of a domain owner is explicitly supported.” + - From O-RAN architecture perspective, PNFs need to be deployed in the live network are not drop-shipped to the end user. PNFs are managed and owned by operators and do not have a separate domain owner or an end user. + - Based on above understanding, from O-RAN architecture perspective, no equipment is considered for drop-shipping. +- From wireless networks point of view, IoT devices may be considered for drop-shipping, however, in current architecture, these devices are not considered to be managed by the telecom network. Hence, using BRSKI for IoT devices can be considered as not applicable from O-RAN point of view. +- RFC 8572 [i.31] describes Secure Zero Touch Provisioning as a bootstrapping strategy enabling devices to securely obtain bootstrapping data with no installer action beyond physical placement and connecting network and power cables. The techniques described in this RFC enable devices to establish secure NETCONF and/or RESTCONF connections with deployment-specific network management systems. This is more relevant for new PNF deployments which require to connect to the operator’s NMS using NETCONF connections. Hence, this RFC 8572 [i.31] can be more relevant for O-RAN and can be considered for live network deployments by operators. +- For devices that intend to become part of an ANI [i.RFC 8993 [i.29]] that includes an Autonomic Control Plane [i.RFC 8994 [i.30]], the BRSKI protocol MUST be implemented. The ACP is normally constructed on a hop-by-hop basis. Therefore, many interactions in the ANI are based on the ANI adjacency table. + - Deployment of an O-RAN network does not require a hop-by-hop network construction using ACP. PNFs can be deployed independently and secure communications with PNFs can be established after initial certificate enrolment using CMPv2. Datacenters hosting CNFs/VNFs also do not require automatic hop-by-hop construction. Considering these aspects, it is understood that O-RAN does not consider any devices or equipment intending to become a part of the ANI, and hence does not mandatorily need usage of BRSKI. +- BRSKI terms new devices as “pledges” and these new devices communicate with a “registrar” for bootstrapping. Bootstrapping is complete when the cryptographic identity of the new key infrastructure is successfully deployed to the device. The established secure connection can be used to deploy a locally issued certificate to the device as well. + - Using CMPv2 new NFs connect to Registration Authority (RA) for initial enrolment. After this initial enrolment, the NF gets Operator’s certificates which it can use for secure communications. + - Conceptually, the logical flow is similar between CMPv2 and BRSKI. The main difference is with respect to the applicability of BRSKI which is for drop-shipped devices and is mandatory for any devices intending to become a part of the ANI. + - CMPv2 based solutions, viz. solution #5 and solution #10 described in this TR provide the required support for initial certificate enrolment of newly deployed PNFs, and are sufficient to address the bootstrapping of PNFs. + +### 5.2.2 Impacts on Existing Interfaces and Functionality + +None. + +### 5.2.3 Solution Evaluation + +Considering the study described above, usage of BRSKI is not applicable for any PNF/CNF/VNF used in O-RAN, specifically because BRSKI is relevant for drop-shipped devices intending to be part of ANI. From O-RAN point of view, none of the devices are drop-shipped and not considered to be part of ANI. BRSKI may be applicable for IoT devices, but these are not managed by telecom networks. + +Also, there is no specific reason or requirement to replace CMPv2 with BRSKI. CMPv2 provides the required protocols for automated certificate management and there are no additional benefits seen by using BRSKI. Moreover, known techniques like SZTP [i.31] which are more relevant for O-RAN, enable non-technical personnel to bring up devices in remote locations without the need for an operator input. + +Moreover, BRSKI is considered mandatory for networks deployed using ANI. However, none of the O-RAN components including PNFs and data-centers hosting the CNFs/VNFs require hop-by-hop construction using ACP. Therefore, BRSKI is not mandatory for O-RAN deployments. + +### 5.2.4 Potential Security Requirements + +None. + +## 5.3 Solution #3: Study the use of EST + +### 5.3.1 Description + +Enrolment over Secure Transport (EST) [i.32] defines a lightweight and straightforward protocol for managing certificate provisioning and enrolment in Public Key Infrastructure (PKI) environments. It focuses on certificate enrolment, and renewal while ensuring the security and integrity of the process by utilizing secure transport protocols like HTTPS. The EST service is located between a Certification Authority (CA) and a client. + +The EST clients and server are both equipped with essential information to establish mutual authentication and authorization. The initialization data may consist of shared secrets, network service names, locations (e.g., Uniform Resource Identifier (URI) [i.39]), and trust anchor information. This data forms the foundation for secure communication and access control between the EST components. + +This solution addresses Key issue 37 for defining a lightweight solution for certificate management using simple PKI message types as defined in RFC 7030 [i.32] over secured transport for certificate enrolment, and renewal. Revocation requests are supported via the /fullcmc interface using the Revocation Request Control defined in clause 6.11 of RFC 5272 [i.35]. This procedure allows certified end entities to make requests for the revocation of certificates. The retrieval of certificate revocation status can be performed using OCSP [i.26] and OCSP stapling [i.17]. + +EST Extensions as defined in RFC 8295 [i.34] adds /crls interface to support CRL distribution. The /crls path component allows servers to distribute CRLs while clients retrieve their certificate(s) and CA certificate(s) as well as peer certificates. Client's request CRLs with an HTTP GET [i.38], using an operation path of "/crls". "The CRL response and its handling follow the same procedures outlined in clause 4.1.3 of [i.32], with one or more CRLs returned in the CRL-only message. + +#### 5.3.1.1 Certificate-less TLS Authentication + +The steps below document the initial enrolment procedure as per clause 3.3.3 of EST [i.RFC 7030 [i.32]]. Certificate-less Mutual Authentication defines a scenario where the client and server do not have certificates or trust anchors to perform mutual authentication. In such cases, TLS-SRP Transport Layer Security-Secure Remote Password (TLS-SRP) can be used, where username and password are pre-configured. TLS-SRP is based on zero-knowledge protocol which provides strong protection against password guessing and eavesdropping and is resistant to dictionary attacks. + +The outlined message flow shows the EST Protocol for enrolment using https. The mutual authentication while establishing the https session is done using the TLS-SRP credentials. + +- a. Operator CA Server information (Example - FQDN/IP, Port, TLS-SRP username and password) is to be configured in NE. +- b. TLS-SRP user credentials is created in the EST Server for enrolment requests. +- c. TLS connection is established based on TLS-SRP [i.29]. +- d. NE initiates the EST CA Certification procedure to download the Operator CA (Root) certificates (or trust chain). +- e. Server responds with a configured operator CA (Root) certificate in response to the CA Certification procedure request from a NE. +- f. NE forms the Certificate Signing Request (CSR) and initiates EST simple enrolment procedure to download the Operator Device Certificate. +- g. Server responds with a Device certificate signed by Operator CA in response to the simple enrolment request from an NE. + +![Sequence diagram for Certificate-less TLS Authentication. The diagram shows the interaction between an NE or NF (EST Client) and an EST Server (CA). The process starts with 'Establish TLS-SRP based connection for https'. A note indicates 'No Explicit or Implicit TA is configured, Certificate-Less Mutual Authentication[TLS-SRP]'. Step 1.a: '1.a TLS-SRP Username, Password and EST Server FQDN are pre-configured'. Step 1.b: '1.b TLS-SRP Username and Password are pre-configured'. A note indicates 'TLS connection established using SRP as defined in RFC 5054[29]'. The next phase is 'EST enrolment using https'. Step 2: '2. EST client uses the /cacerts response to establish TLS connection [HTTP Request(uri=/well-known/est/cacerts/)]'. Step 3: '3. EST server responds with certs to establish new TLS connection [HTTP Response (Operator's CA Certificates)]'. Step 4: '4. EST clients request a certificate from the EST server with an HTTPS POST using the operation path value of /simpleenroll [HTTP Request(uri=/well-known/est/simpleenroll/)]'. Step 5: '5. EST server issues a signed certificate corresponding to the CSR [HTTP Response(NE's operator Certificates)]'.](17007e88d73d5cbd5519a68ca855e792_img.jpg) + +Sequence diagram for Certificate-less TLS Authentication. The diagram shows the interaction between an NE or NF (EST Client) and an EST Server (CA). The process starts with 'Establish TLS-SRP based connection for https'. A note indicates 'No Explicit or Implicit TA is configured, Certificate-Less Mutual Authentication[TLS-SRP]'. Step 1.a: '1.a TLS-SRP Username, Password and EST Server FQDN are pre-configured'. Step 1.b: '1.b TLS-SRP Username and Password are pre-configured'. A note indicates 'TLS connection established using SRP as defined in RFC 5054[29]'. The next phase is 'EST enrolment using https'. Step 2: '2. EST client uses the /cacerts response to establish TLS connection [HTTP Request(uri=/well-known/est/cacerts/)]'. Step 3: '3. EST server responds with certs to establish new TLS connection [HTTP Response (Operator's CA Certificates)]'. Step 4: '4. EST clients request a certificate from the EST server with an HTTPS POST using the operation path value of /simpleenroll [HTTP Request(uri=/well-known/est/simpleenroll/)]'. Step 5: '5. EST server issues a signed certificate corresponding to the CSR [HTTP Response(NE's operator Certificates)]'. + +Figure 5-1: Certificate-less TLS Authentication + +#### 5.3.1.2 Certificate TLS Authentication + +The steps below document the initial enrolment procedure as per clause 3.3.1 of EST [i.RFC 7030 [i.32]]. The EST client authenticates the EST server using the certificate validation as defined in RFC 5280 [i.13]. The authorization method for the EST server depends on whether the EST Client is configured with an Explicit TA Database as per clause 3.6.1 of RFC 7030 [i.32] or an Implicit TA Database as per clause 3.6.2 of RFC 7030 [i.32]. In the below scenario, an explicit TA database has been configured for mutual authentication between EST Client and Server. + +The outlined message flow shows the EST Protocol for enrolment using https. The mutual authentication while establishing https session is done using the certificates. + +- NE's Vendor certificate and Private Keys are pre-installed. +- Vendor CA Certificate (or trust chain) is installed in the Operator CA server trust store. +- NE has received the Operator CA server details (Example - FQDN/IP, Port, Operator CA certificate). +- TLS connection is established based on the Explicit TA database. +- NE forms the CSR and initiate EST simple enrolment procedure to download the Operator Device Certificate. +- Server validates the client's identity and responds with a Device certificate signed by Operator CA in response to the simple enrolment request from a NE. + +![Sequence diagram for Certificate-based TLS Authentication. The diagram shows the interaction between an NE or NF (EST Client) and an EST Server (CA). The process starts with 'Establish TLS connection based on Explicit TA database for https'. A note indicates 'Explicit TA is configured, Certificate Based Mutual Authentication is used'. Step 1: '1. NE's Vendor certificate and private key are pre-installed'. Step 2: '2. Vendor CA certificate are pre-configured'. Step 3: '3. EST server's FQDN and CA certificates are pre-configured'. A note indicates 'TLS connection is established based on the Explicit TA database as per RFC7030[28]'. Step 4: '4. Generate CSR'. The next phase is 'EST enrolment using https'. Step 5: '5. Send the CSR to the EST server [HTTP Request(uri=/well-known/est/simpleenroll/)]'. Step 6: '6. Validate the client's identity and authorization status'. Step 7: '7. EST server issues a signed certificate corresponding to the CSR [HTTP Response(NE's operator Certificates)]'.](3ea0f3866b1d87d30d1ee575085c7d35_img.jpg) + +Sequence diagram for Certificate-based TLS Authentication. The diagram shows the interaction between an NE or NF (EST Client) and an EST Server (CA). The process starts with 'Establish TLS connection based on Explicit TA database for https'. A note indicates 'Explicit TA is configured, Certificate Based Mutual Authentication is used'. Step 1: '1. NE's Vendor certificate and private key are pre-installed'. Step 2: '2. Vendor CA certificate are pre-configured'. Step 3: '3. EST server's FQDN and CA certificates are pre-configured'. A note indicates 'TLS connection is established based on the Explicit TA database as per RFC7030[28]'. Step 4: '4. Generate CSR'. The next phase is 'EST enrolment using https'. Step 5: '5. Send the CSR to the EST server [HTTP Request(uri=/well-known/est/simpleenroll/)]'. Step 6: '6. Validate the client's identity and authorization status'. Step 7: '7. EST server issues a signed certificate corresponding to the CSR [HTTP Response(NE's operator Certificates)]'. + +Figure 5-2: Certificate-based TLS Authentication. + +### 5.3.2 Impacts on Existing Interfaces and Functionality + +Impacts on Existing Interfaces and Functionality are FFS. + +### 5.3.3 Solution Evaluation + +The choice for selecting a certificate management protocol could depend upon the PKI environment. EST provides a lightweight solution in case the environment does not govern a complex PKI infrastructure and features. The EST server authenticates and authorizes the EST client based on the method described in clause 4.3.1.1 and 4.3.1.2. The recommended method for establishing TLS secured http connection between EST client and server should be based on certificate based TLS authentication. EST could also be used between the client and RA and co-exist with CMPv2. + +Benefits: + +- Lightweight Protocol with simple PKI messaging types. +- Secured Transport using HTTPS. +- Source Code is open-sourced. +- Efficient and well-suited for edge deployments where the resources are constrained. +- Supports Elliptic Curve Cryptography. + +Limitations: + +- In scenarios where a client doesn't have proper configuration or trust anchors, manual intervention by a human user is required to verify CA certificate information. + +### 5.3.4 Potential Security Requirements + +An O-RAN element that requires digital certificates should support the Enrolment over Secure Transport (EST) to securely provision RSA or ECC certificates over HTTPS, as described in RFC 7030. EST is a lightweight certificate management protocol that allows enrolment/renewal of digital certificates over a secured https and support all the below conditions. + +- a. An O-RAN element which has not been bootstrapped with digital certificates. +- b. An O-RAN element using vendor certificates but missing trust anchor database or CA information not being passed by the DHCP options. + +## 5.4 Solution #4: Study the use of ACME + +### 5.4.1 Description + +Study the use of ACME instead of OR along with CMPv2. + +O-Cloud hosts O-RAN functions such as O-DU, O-CU, Near-RT RIC platform services, xApps, and O-Cloud control plane components. (e.g., Kubernetes control plane components). + +The CMPv2 protocol can be used to provision certificates to O-DU, O-CU functions. However, for cloud-native applications (such as xApps), Near-RT RIC platform components, and O-Cloud control plane components deployed as pods, ACME offers a solution for automated certificate management. + +Manually maintaining the certificates for cloud-native applications and O-Cloud control plane components present challenges: + +- Large number of TLS certificates to manage across Kubernetes clusters and namespaces. +- Manually replace certificates every time when they expire. +- Certificates expire at different times; service outages may result if certificates are not renewed in time. +- Updating Kubernetes secrets manually is error-prone. +- Manual certificate management is time-consuming and error-prone. + +- The risk-mitigating practice of rotate keys and certificates frequently aggravates the onerousness of manual certificate management. + +#### 5.4.1.1 Overview of ACME + +ACME is a certificate management protocol defined in RFC 8555 [i.42]. A popular use of ACME is to request certificate from Let's Encrypt, a free public CA. The protocol is also supported by some commercial CAs. + +The ACME builds on several existing technologies, most of which are commonly used in web API designs: + +- HTTPS (transport) +- JSON (message format) +- TLS server authentication (authentication of messages from server) +- JWS (authentication of messages from clients) +- PKCS #10 (CSR) + +ACME supports several certificate management use cases: + +- requisition (a.k.a. enrolment) +- certificate revocation +- subject identifier validation + +In ACME, a client needs to have an account to be able to use the service of an ACME server. A client account is identified with an account key pair. Among certificate enrolment protocols, ACME is unusual in that it has provisions for extensible, automated in-protocol processes for validating identifiers (e.g. DNS domain) of certificate subjects. This allows ACME accounts to be set up by clients without pre-established credentials, as a client's eligibility to receive a certificate with a particular subject identifier not based on trust of the client, but independent validation of the client's control of the subject identifier. RFC 8738 [i.43] extends ACME to issue certificates with IP address identifiers using http-01 and tls-alpn-01 challenges. Additional extensions and proposed extensions can be found at . + +ACME has mechanisms for integrating with external systems. "External account binding" allows an ACME account to be tied to an account external (using a MAC-authenticated credential), and allows authorization to be performed via the external account. ACME also supports an operation called preauthorization, which allows a client to request authorization for a subject identifier outside of the context of a certificate request sequence. + +In ACME, a certificate request sequence involves the creation and update of several types of objects: + +- order +- authorization +- challenge + +Messages from the client are authenticated using JWS signed with the client's account private key. To protect against replay attacks, requests from the client contain a replay-nonce. Some of the request-response exchanges are asynchronous in the general case. In those exchanges, after receiving an immediate response from the server, the client may need to poll the server periodically until a status change has occurred. + +#### 5.4.1.2 ACME Certificate Enrolment Flow + +![A simplified depiction of the workings of ACME showing the interaction between an ACME Client, an ACME Server, and an Operator CA.](4a705d49812d6231d2083e7f42cada54_img.jpg) + +``` + +sequenceDiagram + participant Client as ACME Client + participant Server as ACME Server + participant CA as Operator CA + + Client->>Server: Submit order + Server-->Client: Issue challenge (e.g. http-01, dns-01) + Client->>Server: Provision resources to fulfill challenge + Server-->Client: Validate challenge + Server-->Client: Issue certificate + Note over Client, Server: ... + Client->>Server: (Renew certificate before expiry) + Server <--> CA + +``` + +The diagram illustrates the ACME Certificate Enrolment Flow. It shows three main components: the ACME Client, the ACME Server, and the Operator CA. The flow begins with the ACME Client submitting an order to the ACME Server. The ACME Server then issues a challenge (e.g., http-01, dns-01) to the ACME Client. The ACME Client provisions resources to fulfill the challenge and sends a validate challenge message to the ACME Server. The ACME Server then issues a certificate to the ACME Client. This process can repeat, with the ACME Client sending a message to the ACME Server to renew the certificate before expiry. The ACME Server and the Operator CA are also shown, with a bidirectional arrow indicating communication between them. + +A simplified depiction of the workings of ACME showing the interaction between an ACME Client, an ACME Server, and an Operator CA. + +Figure 5-3: A simplified depiction of the workings of ACME + +In ACME, message exchanges happen over HTTPS. The ACME specification defines a way of using an HTTP POST request to perform what an HTTP GET request usually does, but with JWS message authentication. The usage is called POST-as-GET in the protocol specification. + +A typical certificate request sequence in ACME involves the follow steps: + +1. **Order creation:** The client performs an HTTP POST to submit a request; the ACME server creates and returns an order object. +2. **Challenge retrieval:** The client uses POST-as-GET request(s) to retrieve the authorization objects referenced in the order object. In the general case, multiple authorization objects may be involved. +3. **Challenge fulfillment:** For each of the authorization object(s), the client selects one (of possibly multiple) challenge in the authorization object, takes action to fulfill the challenge, and POSTs to a URL to notify the ACME server of the challenge selected and it has been fulfilled. +4. **Challenge validation:** The ACME server verifies that the client has fulfilled the indicated challenges, e.g. by performing an HTTP request or a DNS query. This validation step may take a variable amount of time. +5. **Polling for status change:** The client performs POST-as-GET requests to check the status of the authorization object(s), until their status(es) are no longer “pending”. +6. **Order finalization:** The client POSTs to a URL contained in the order object, including a CSR in the request. There may be a variable amount of delay before the ACME server issues a certificate. +7. **Polling for status change:** The client performs POST-as-GET requests to check the status of the order object(s), until its status is “ready”. +8. **Certificate download:** The client performs a POST-as-GET to download a newly-issued certificate from a URL in the updated order object. + +#### 5.4.1.3 Integration with Kubernetes via cert-manager + +cert-manager (name spelled in all lowercase) is an add-on to Kubernetes (K8s). As of August 2022, cert-manager is a CNCF project of maturity level “sandbox” (in a progression of three maturity levels: sandbox, incubating, and graduated.) cert-manager can generate key pairs and request certificates from CAs and provision the key pairs and certificates to containerized applications, in a Kubernetes construct called secrets. cert-manager can be integrated with CAs of several types. Using a built-in ACME client, cert-manager can request certificates from CAs that support an ACME interface. cert-manager can also monitor certificates it manages and automatically requests replacements for certificates before they expire. + +#### 5.4.1.4 Remarks + +Compared with other certificate management protocols, ACME is rather “chatty” in that a typical certificate request sequence involves a relatively large number of request-response exchanges. + +Although the pre-integration with ACME makes cert-manager an attractive certificate management option for containerized applications orchestrated using Kubernetes, private keys generated by cert-manager are only protected by access control. Private keys are exposed in plaintext form to anyone who has or managed to obtain privileged access (e.g., superuser access) inside a container. + +### 5.4.2 Impacts on Existing Interfaces and Functionality + +Impacts on Existing Interfaces and Functionality are FFS. + +### 5.4.3 Solution Evaluation + +Addressing Key Issue #37, ACME provides a solution for PKI certificate management protocol and procedures. In contrast to CMPv2, ACME is a dedicated protocol for certificate provisioning that is based on easy-to-implement REST interfaces and the HTTP protocol. It is therefore easier to implement in resource-restricted client implementations as well as in the certificate authority (trust center). CMPv2, however, is a very complex binary (ASN1-based) protocol with a feature set that well exceeds what is needed for certificate provisioning. + +Addressing Key Issue #38, ACME provides a solution for PKI certificate management protocol and procedures. Because of its dedication to certificate provisioning and the use of RESTful APIs it is easier to understand for developers leading potentially to a better conformance and therefore higher interoperability of ACME implementations. For CMPv2, however, variances in implementations may lead to more interoperability problems due its higher complexity and the need to observe a large number of specifications with regard to its deployment in an O-RAN context (ie. original RFCs, 3GPP profiles, potentially O-RAN Alliance profiles). + +## 5.5 Solution #5: Initial Certificate Enrolment of PNFs using vendor certificates + +### 5.5.1 Description + +This solution addresses Key Issue #3 and Key Issue #4. + +When a new physical network function (PNF) gets deployed in a network, it can obtain operator's CA signed certificate in order to establish secure communications with other network functions. An operator may prefer using vendor-signed certificates for automated initial certificate enrolment. This solution proposes the procedure to use vendor-signed certificates for initial certificate enrolment of PNFs. This solution proposal refers to vendor certificate-based initial registration and certificate enrolment as described in 3GPP TS 33.310 [i.2] clause 9 "Certificate enrolment for base stations". + +The solution is summarized as below: + +Pre-conditions: + +When a PNF is deployed in the network, for initial certificate enrolment, it requires vendor-signed certificate and the related private key, and operator's CA certificate. + +- Also, PNF needs to be configured with the URL/IP address for RA/CA. + - As described in 3GPP TS 28.315 [i.44] clause 5.3, operators may deploy their management infrastructure in a manner that either IP address or FQDN of RA/CA is known to the PNF. + - The plug-and-connect concepts as described in 3GPP TS 28.314 [i.45] and 3GPP TS 28.315 [i.44] should be followed. +- CA/RA has the vendor's root certificate pre-provisioned. + - 3GPP TS 28.314 [i.45] clause 4.1.3.1 should be followed for root certificate acquisition. + - RA is an optional entity, and the registration function can be directly implemented with the CA component. RFC 4210 [i.5] (for CMPv2) describes possible reasons for the presence of RA in Appendix A of the RFC. + +Initial Certificate Enrolment: + +- 3GPP TS 33.310 [i.2] Annex G presents an example CMPv2 message flow for initial enrolment, and this should be followed. +- When PNFs have connectivity with CA/RA, and above pre-conditions are satisfied, vendor-signed certificate gets used to perform initial certificate enrolment. +- PNF presents the vendor-signed certificate to CA/RA during CMPv2: Initialization Request. CA/RA having vendor's root certificate can authenticate this request and, the CMPv2 protocol can be followed, as defined in RFC 4210 [i.5], to establish the trust. + +This trust establishment allows newly deployed PNFs to obtain operator CA issued certificate along with the chain of trust. + +### 5.5.2 Impacts on Existing Interfaces and Functionality + +An O-RAN PNF requiring a PKI certificate will need to support CMPv2 and will need a pre-installed vendor certificate. Offline interfaces will be required to configure the URL/IP address of the RA/CA in the PNF. + +Offline interfaces will also be required to pre-provision vendor's trust anchor in RA/CA. + +Pre-condition: In order to facilitate vendor certificate-based initial enrolment of PNFs, vendor's trust anchor is pre-installed in operator's RA/CA. + +### 5.5.3 Solution Evaluation + +This solution addresses Key Issue #3 and Key Issue #4. + +### 5.5.4 Potential Security Requirements + +In order to facilitate vendor certificate-based initial enrolment of PNFs, vendors should pre-install vendor-signed certificates in PNFs. + +In order to facilitate vendor certificate-based initial enrolment of PNFs, operators should pre-configure the FQDN/IP address of RA/CA in PNFs. + +## 5.6 Solution #6: Certificate management and secure storage of Application private keys within O-Cloud + +### 5.6.1 Description + +The O-Cloud platform should have a certificate manager (e.g., "cert-manager" for Kubernetes [i.]) that supports secure protocols such as ACME and (CMPv2 is not yet implemented), which can be used to obtain certificates from other sources. This certificate manager is used to inject certificates in O-RAN Applications. In order to do that, the certificate manager should use a trusted CA to sign the certificate request. + +ACME or CMPv2 protocols support the integration with a PKI-as-a-Service to obtain certificates from any PKI, whether public or private, that support security modules like HSMs. This enables secure, automatic issuance of a unique, trusted identity certificate for every application and O-Cloud component. + +Certificates and private keys should be stored within the O-Cloud platform as secrets (e.g., native k8s Secrets Objects). Private keys should be protected in terms of confidentiality and integrity. + +### 5.6.2 Generation of key pair and modes of operation + +The ETSI GR NFV-SEC 005 [i.11] clause 8 is describing the key-generation and distribution for NFV certificate lifecycle management, specifically three different concepts are shown. + +In this clause the different key-generation concepts have been taken as basis for further development of the key-generation and certificate enrolment. + +The following Figure 5-4 is depicting the system level view for the secure storage and certificate management. + +![Figure 5-4: Secure Storage and Certificate Management Architecture (System Level View). The diagram shows a multi-layered architecture. At the top is the 'Software Level' containing 'O-RAN APP/VNF/CNF (AVC)'. Below this is the 'Platform Level' containing 'Virtualisation Platform (VP)' and 'Certificate Manager'. The 'VP' contains a 'Monitor' and 'Secure Storage Resource Manager (SSRM)'. At the bottom is the 'Infrastructure Level' containing 'SW Based Secure Storage' (Option A: SW-Based) and 'HW Based Secure Storage (e.g. HSM, TPM)' (Option B: HW-Based). Arrows indicate data flow: 'O-RAN APP/VNF/CNF (AVC)' connects to 'Certificate Manager' via 'Functional API' and 'Secure Storage API'. 'Certificate Manager' connects to 'RA / CA' and 'Security Module (e.g. HSM)'. 'Certificate Manager' also connects to 'MANO / CISM'. 'SSRM' connects to both 'SW Based Secure Storage' and 'HW Based Secure Storage'. A legend on the right defines key types: Private Key (red), Public Key (blue), Root CA Private Key (black), and Root CA Public Key (purple).](4730faae08b7e31f0c52317f4cd78595_img.jpg) + +Figure 5-4: Secure Storage and Certificate Management Architecture (System Level View). The diagram shows a multi-layered architecture. At the top is the 'Software Level' containing 'O-RAN APP/VNF/CNF (AVC)'. Below this is the 'Platform Level' containing 'Virtualisation Platform (VP)' and 'Certificate Manager'. The 'VP' contains a 'Monitor' and 'Secure Storage Resource Manager (SSRM)'. At the bottom is the 'Infrastructure Level' containing 'SW Based Secure Storage' (Option A: SW-Based) and 'HW Based Secure Storage (e.g. HSM, TPM)' (Option B: HW-Based). Arrows indicate data flow: 'O-RAN APP/VNF/CNF (AVC)' connects to 'Certificate Manager' via 'Functional API' and 'Secure Storage API'. 'Certificate Manager' connects to 'RA / CA' and 'Security Module (e.g. HSM)'. 'Certificate Manager' also connects to 'MANO / CISM'. 'SSRM' connects to both 'SW Based Secure Storage' and 'HW Based Secure Storage'. A legend on the right defines key types: Private Key (red), Public Key (blue), Root CA Private Key (black), and Root CA Public Key (purple). + +Figure 5-4: Secure Storage and Certificate Management Architecture (System Level View) + +The following is applicable: + +- The Virtualisation Platform (VP) includes the Secure Storage Resource Manager (SSRM). The SSRM is managing the interface to either the SW based or HW based secure storage solution. The VM/Container is owning a more 'internal' interface to SSRM (which is like a primitive between protocol stacks). The SSRM is providing service for key-pair generation and provision of the public key, is providing digital signatures, is providing key-management, etc. +- The underlying HW based secure storage can be either implemented by a TPM device (HW or SW) or can be by a (physically) connected HSM module. +- Any Application or certificate manager have access to SSRM service. +- The management and orchestration system (e.g., MANO for VM [i.11], CIS/CISM for Container [i.12]) is receiving the operator public key on request for distribution to other Applications. +- The Operator RA/CA has connected its own HSM module which is creating the private key for signing requests. + +### 5.6.2.1 Generation of the key pair by the Virtualization Platform + +In this mode, the key pair is generated by the SSRM following the request of the certificate manager. The certificate manager could automatically ensure certificates are valid and up to date and attempt to renew certificates at a configured time before expiry. + +The following steps are followed to request and store certificates: + +1. An Application creates and sends a certificate resource request to the certificate manager +2. The certificate manager requests from the SSRM the generation of a key pair and sends a Certificate Signing Request (CSR) to the CA +3. The CA signs the certificate with its own private key and returns it to the certificate manager. +4. The certificate manager stores the signed certificate in the secret storage volume with the O-Cloud platform (e.g., in etcd). +5. Authenticated and authorized Application can read the signed certificate from the secret storage volume for use and for digital signing service is (direct) requesting digital signature from the SSRM by providing the digest for signing. + +![Figure 5-5: Key-generation by the Virtualisation Platform. This diagram illustrates the key-generation process across three levels: Software Level, Platform Level, and Infrastructure Level. At the Software Level, the O-RAN APP/VNF/CNF (AVC) interacts with the RA/CA and the Security Module (e.g., HSM). At the Platform Level, the Virtualisation Platform (VP) contains the Certificate Manager and the Secure Storage Resource Manager (SSRM), which includes a Monitor component. The VP interacts with the MANO/CISM. At the Infrastructure Level, the SSRM interacts with two options for secure storage: Option A: SW-Based (SW Based Secure Storage) and Option B: HW-Based (HW Based Secure Storage, e.g., HSM, TPM). A Secure Storage API connects the AVC to the SSRM. A legend defines the key types: Private Key (red key icon), Public Key (blue key icon), Root CA Private Key (black key icon), and Root CA Public Key (purple key icon).](9fc87a46cd2ba9c63014d1142fe15d13_img.jpg) + +Figure 5-5: Key-generation by the Virtualisation Platform. This diagram illustrates the key-generation process across three levels: Software Level, Platform Level, and Infrastructure Level. At the Software Level, the O-RAN APP/VNF/CNF (AVC) interacts with the RA/CA and the Security Module (e.g., HSM). At the Platform Level, the Virtualisation Platform (VP) contains the Certificate Manager and the Secure Storage Resource Manager (SSRM), which includes a Monitor component. The VP interacts with the MANO/CISM. At the Infrastructure Level, the SSRM interacts with two options for secure storage: Option A: SW-Based (SW Based Secure Storage) and Option B: HW-Based (HW Based Secure Storage, e.g., HSM, TPM). A Secure Storage API connects the AVC to the SSRM. A legend defines the key types: Private Key (red key icon), Public Key (blue key icon), Root CA Private Key (black key icon), and Root CA Public Key (purple key icon). + +Figure 5-5: Key-generation by the Virtualisation Platform + +### 5.6.2.2 Generation of the key pair by Trusted Application + +In this mode, the key pair is generated by the Trusted (i.e., authenticated, and authorized) Application. In this mode, the life cycle of the certificate is to be managed by the Application and it is the responsibility of the Application to renew the certificates before they expire. + +The following steps are followed to request and store certificates: + +1. Trusted Application generates a key pair. +2. The Trusted Application sends the public key back to the certificate manager. The certificate manager sends the CSR to the CA for signing. +3. The CA signs the certificate with its own private key and returns it to the certificate manager. +4. The certificate manager returns the signed certificate. +5. The trusted Application requests the SSRM to store its private key with the signed certificate in the secure storage. + +![Figure 5-6: Key-generation by the Trusted Application. This diagram illustrates the key-generation process across three levels: Software Level, Platform Level, and Infrastructure Level. At the Software Level, the O-RAN APP/VNF/CNF (AVC) contains a Trusted AVC. At the Platform Level, the Virtualisation Platform (VP) contains a Certificate Manager and a Secure Storage Resource Manager (SSRM). At the Infrastructure Level, there are two options for secure storage: Option A (SW-Based) and Option B (HW-Based). The Trusted AVC interacts with the Certificate Manager via Functional API and Secure Storage API. The Certificate Manager interacts with the SSRM and the RA/CA. The RA/CA interacts with a Security Module (e.g., HSM). The SSRM interacts with the SW Based Secure Storage or HW Based Secure Storage (e.g., HSM, TPM). A MANO/CISM module is also connected to the Certificate Manager. A legend defines the key types: Private Key (red key icon), Public Key (blue key icon), Root CA Private Key (black key icon), and Root CA Public Key (purple key icon).](d11ea352254574022d9ef7922e32d7b9_img.jpg) + +Figure 5-6: Key-generation by the Trusted Application. This diagram illustrates the key-generation process across three levels: Software Level, Platform Level, and Infrastructure Level. At the Software Level, the O-RAN APP/VNF/CNF (AVC) contains a Trusted AVC. At the Platform Level, the Virtualisation Platform (VP) contains a Certificate Manager and a Secure Storage Resource Manager (SSRM). At the Infrastructure Level, there are two options for secure storage: Option A (SW-Based) and Option B (HW-Based). The Trusted AVC interacts with the Certificate Manager via Functional API and Secure Storage API. The Certificate Manager interacts with the SSRM and the RA/CA. The RA/CA interacts with a Security Module (e.g., HSM). The SSRM interacts with the SW Based Secure Storage or HW Based Secure Storage (e.g., HSM, TPM). A MANO/CISM module is also connected to the Certificate Manager. A legend defines the key types: Private Key (red key icon), Public Key (blue key icon), Root CA Private Key (black key icon), and Root CA Public Key (purple key icon). + +Figure 5-6: Key-generation by the Trusted Application + +### 5.6.2.3 Generation of the key pair by a HW security module (e.g., HSM, TPM) + +In this mode, the key pair is generated by the connected HW security module (e.g., HSM, TPM). The security module is connected to the virtualization platform via the SSRM, which is then used for generation of a key pair. + +In this mode, the life cycle of the certificate is to be managed by the Application and it is the responsibility of the Application to renew the certificates before they expire. + +The following steps are followed to request and store certificates: + +1. An Application creates and sends a certificate resource request to the certificate manager +2. The certificate manager is creating a key-pair generation request to the security module. The security module is creating the key-pair and is sending the public key back to the certificate manager. The certificate manager sends the CSR to the CA for signing. +3. The CA signs the certificate with its own private key and returns it to the certificate manager. +4. The certificate manager returns the signed certificate. +5. The security module stores the private key, and the signed certificate is going to the Application. + +![Figure 5-7: Key-generation by the Secure Module (e.g., HSM, TPM). The diagram illustrates a three-tier architecture: Software Level, Platform Level, and Infrastructure Level. At the Software Level, the O-RAN APP/VNF/CNF (AVC) contains a Trusted AVC. At the Platform Level, the Virtualisation Platform (VP) contains a Certificate Manager and a Secure Storage Resource Manager (SSRM). At the Infrastructure Level, there are two options: Option A (SW-Based) with SW Based Secure Storage, and Option B (HW-Based) with HW Based Secure Storage (e.g., HSM, TPM). A Security Module (e.g., HSM) is connected to the RA/CA and the Certificate Manager. A MANO/CISM module is also connected to the Certificate Manager. Arrows indicate data flow and control between these components. A legend defines key types: Private Key (red), Public Key (blue), Root CA Private Key (black), and Root CA Public Key (purple).](3ee904708d309edeed423952cd8bc283_img.jpg) + +Figure 5-7: Key-generation by the Secure Module (e.g., HSM, TPM). The diagram illustrates a three-tier architecture: Software Level, Platform Level, and Infrastructure Level. At the Software Level, the O-RAN APP/VNF/CNF (AVC) contains a Trusted AVC. At the Platform Level, the Virtualisation Platform (VP) contains a Certificate Manager and a Secure Storage Resource Manager (SSRM). At the Infrastructure Level, there are two options: Option A (SW-Based) with SW Based Secure Storage, and Option B (HW-Based) with HW Based Secure Storage (e.g., HSM, TPM). A Security Module (e.g., HSM) is connected to the RA/CA and the Certificate Manager. A MANO/CISM module is also connected to the Certificate Manager. Arrows indicate data flow and control between these components. A legend defines key types: Private Key (red), Public Key (blue), Root CA Private Key (black), and Root CA Public Key (purple). + +Figure 5-7: Key-generation by the Secure Module (e.g., HSM, TPM) + +### 5.6.3 Secure key and file storage + +Encryption/decryption functionality is provided by the management platform and handled by the CPU's accelerated instruction, providing accelerated data at rest for both AES encryption and decryption. The main assets involved in the encryption/decryption of private keys are the key encryption key (KEK), the disk encryption key (DEK) and/or the secret encryption key (SEK). Different solutions for protecting those keys in terms of integrity and confidentiality are currently used. Such potential solutions include: + +#### 5.6.3.1 Secure Key and File Storage Mechanisms – Architecture Framework + +The main purpose for implementing a secure storage is to guarantee the secrecy of a private key (asymmetric cryptography) and/or of a file which might hold sensitive information. The secure storage in this context is a composition of sub-functions which all together are required to provide service to upper layer for a proper secure key and file protection. + +The following Figure 5-8 depicts the overall architecture framework for a secure key and file storage. + +![Figure 5-8: Secure Key and File Storage Architecture Framework (overview). The diagram shows a multi-layered architecture. At the top is the 'Software Level' containing O-RAN APP/VNF/CNF (#1), (#2), and (#N). Below this is the 'Platform Level' containing the 'Secure Storage API'. The 'Secure Storage Resource Manager' (SSRM) is located between the Platform Level and the 'Infrastructure Level'. The SSRM includes a 'Monitor' component. The 'Infrastructure Level' contains two options: 'Option A: SW-Based' (SW Based Secure Storage) and 'Option B: HW-Based' (HW Based Secure Storage, e.g., TPM). The SSRM interacts with both options via a 'Secure Storage API'. The diagram also indicates 'ORAN Normative Specification' and 'ORAN Informative Specification' layers.](a71f57b0d2d79fd352e551f9580a2602_img.jpg) + +Figure 5-8: Secure Key and File Storage Architecture Framework (overview). The diagram shows a multi-layered architecture. At the top is the 'Software Level' containing O-RAN APP/VNF/CNF (#1), (#2), and (#N). Below this is the 'Platform Level' containing the 'Secure Storage API'. The 'Secure Storage Resource Manager' (SSRM) is located between the Platform Level and the 'Infrastructure Level'. The SSRM includes a 'Monitor' component. The 'Infrastructure Level' contains two options: 'Option A: SW-Based' (SW Based Secure Storage) and 'Option B: HW-Based' (HW Based Secure Storage, e.g., TPM). The SSRM interacts with both options via a 'Secure Storage API'. The diagram also indicates 'ORAN Normative Specification' and 'ORAN Informative Specification' layers. + +Figure 5-8: Secure Key and File Storage Architecture Framework (overview) + +The SSRM is providing service to any application, i.e., is creating private-public key pair, is providing digital signing requests on received digests, is returning the digital certificates, etc. Any application is connecting to SSRM via a standardised Secure Storage API (SSAPI). This API is independent of the underlying secure storage mechanism. The storage mechanism can be built up by a single secure storage instance or by multiple secure storage instances. Their management is up to the SSRM. + +The following is applicable: + +- The O-RAN Application is interfaced to the Secure Storage Resource Manager (SSRM) via a Secure Storage API. +- The role of the SSRM is to provide service on secure storage to any Application, and to hide the underlying protection mechanism which can be either SW-based and/or HW-based. The Monitor function belongs to the SSRM and is for tracking purposes or could be used as proxy towards the system O&M. +- The secure storage mechanism could be a SW based approach (e.g., vTPM) and/or HW-based (e.g., TPM, HSM). +- The HW-based solution option is impacting the HW and therefore is belonging to Infrastructure. The SSRM (including the SS API) and the SW-based solution option is belonging to the Platform. The O-RAN Application is belonging to the application SW level. + +### 5.6.3.2 Scenarios for protecting keys within the secret storage volume + +#### 5.6.3.2.1 Use of TPM (Hardware TPM or vTPM) + +In this solution, two scenarios are possible, among others: + +1. Scenario 1: Private keys are not encrypted individually. All private keys are stored in a disk encrypted by the DEK. DEK is stored in a TPM for automatic decryption at boot. +2. Scenario 2: Private keys could be encrypted individually by SEKs. SEKs are stored in a disk encrypted by the KEK. KEK is stored in a TPM. + +### Scenario 1 + +![Diagram of Scenario 1: Protecting keys within the secret storage volume based on TPM. The diagram shows O-RAN Apps/VNFs/CNFs connected to a Secure Storage Resource Manager. The manager is connected to a Secret storage volume (containing three private keys labeled 1, 2, 3) and a TPM. A yellow arrow points from the TPM to the Secret storage volume. A legend on the right indicates: Private keys (orange key icon), DEK (yellow key icon).](307b416dc3cadad68af189331058fc3d_img.jpg) + +Diagram of Scenario 1: Protecting keys within the secret storage volume based on TPM. The diagram shows O-RAN Apps/VNFs/CNFs connected to a Secure Storage Resource Manager. The manager is connected to a Secret storage volume (containing three private keys labeled 1, 2, 3) and a TPM. A yellow arrow points from the TPM to the Secret storage volume. A legend on the right indicates: Private keys (orange key icon), DEK (yellow key icon). + +### Scenario 2 + +![Diagram of Scenario 2: Protecting keys within the secret storage volume based on TPM. The diagram shows O-RAN Apps/VNFs/CNFs connected to a Secure Storage Resource Manager. The manager is connected to a Secret storage volume (containing two private keys labeled 1, 2) and a TPM. Two red arrows point from the TPM to the Secret storage volume. A legend on the right indicates: Private keys (orange key icon), KEK (red key icon), SEKs (blue key icon).](1f4a755880ec884c749645a8b354cb24_img.jpg) + +Diagram of Scenario 2: Protecting keys within the secret storage volume based on TPM. The diagram shows O-RAN Apps/VNFs/CNFs connected to a Secure Storage Resource Manager. The manager is connected to a Secret storage volume (containing two private keys labeled 1, 2) and a TPM. Two red arrows point from the TPM to the Secret storage volume. A legend on the right indicates: Private keys (orange key icon), KEK (red key icon), SEKs (blue key icon). + +Figure 5-9: Scenarios for protecting keys within the secret storage volume based on TPM + +#### 5.6.3.2.2 Use of KMS server + +There is a specific SEK for each private key. The SEK is used to encrypt the private key and is itself encrypted by the KMS server's KEK. The KMS server may use an HSM for the storage of the KEK and the encryption of SEKs. The HSM if used by the KMS server may or may not be the same as the HSM used by the CA. + +![Diagram of Figure 5-10: Key protection based on KMS. The diagram shows O-RAN Apps/VNFs/CNFs connected to a Secure Storage Resource Manager. The manager is connected to a Secret storage volume (containing two private keys labeled 1, 2) and a KMS server. The KMS server contains a Security Module (e.g., HSM). Two red arrows point from the Security Module to the Secret storage volume. A legend on the right indicates: Private keys (orange key icon), KEK (red key icon), SEKs (blue key icon).](18b5fb33f7aac3096bc5195f8fa7a025_img.jpg) + +Diagram of Figure 5-10: Key protection based on KMS. The diagram shows O-RAN Apps/VNFs/CNFs connected to a Secure Storage Resource Manager. The manager is connected to a Secret storage volume (containing two private keys labeled 1, 2) and a KMS server. The KMS server contains a Security Module (e.g., HSM). Two red arrows point from the Security Module to the Secret storage volume. A legend on the right indicates: Private keys (orange key icon), KEK (red key icon), SEKs (blue key icon). + +Figure 5-10: Key protection based on KMS + +## 5.6.4 Impacts on Existing Interfaces and Functionality + +Solution #6, focusing on the implementation of certificate management and secure storage of application private keys within the O-Cloud, substantially impacts the O-Cloud architecture by elevating its security framework. The O-Cloud should incorporate the following components and mechanisms: + +The O-Cloud should support a certificate manager for the automated handling of digital certificate lifecycle processes, including the generation, issuance, renewal, and revocation of certificates. This certificate manager should be capable of integrating with various Certificate Authorities (CAs) and support secure protocols such as ACME, CMPv2, etc., for seamless certificate procurement. It must be designed to facilitate secure, automatic issuance of unique, trusted identity certificates for every application and component within the O-Cloud. + +The O-Cloud should support secure storage and deletion mechanisms for protecting private keys during their entire lifecycle. This involves several critical components and processes: + +1. Secure key generation: Private keys should be generated in a secure environment, possibly using HSMs or TPMs, to ensure that they are never exposed to less secure environments or unauthorized entity. +2. Encrypted storage: Once generated, private keys should be stored in encrypted form. The encryption should be strong enough to prevent unauthorized access. +3. Access control: Strict access controls should be implemented to ensure that only authorized applications can access the private keys. +4. Regular updates and renewal: The O-Cloud should support automated renewal and update processes for keys and certificates, ensuring that they are replaced or updated before they expire or become vulnerable due to advancements in cryptographic attacks or if there is a need to change the CA signing the certificates for Applications. Also, during any such updates, it should be ensured that there is no service interruption. +5. Secure deletion: When a private key is no longer needed, it should be securely deleted. Secure deletion ensures that the key is irrecoverable, preventing any possibility of unauthorized use. This can be achieved through techniques like cryptographic erasure, where the key is made inaccessible by destroying the encryption key used to encrypt the private key. +6. Backup: While maintaining the security of private keys, the O-Cloud should also support secure backup. These backups should be encrypted and stored securely. + +## 5.6.5 Solution Evaluation + +This solution addresses Key Issue #20. + +## 5.6.6 Potential Security Requirements + +In addition to the existing security requirements in Clause 5.1.8.6 of [i.47] focused on the secure storage and deletion of sensitive data within the O-Cloud platform, the following potential security requirements are proposed to ensure secure handling of private keys and certificates within the O-Cloud: + +- The O-Cloud should provide mechanisms for managing the entire lifecycle of digital certificates, including (re-)issuance, renewal, revocation, and expiration. +- The O-Cloud should support automated renewal processes for certificates to avoid service interruptions due to expired/revoked certificates or during any PKI migration (change in CAs used for signing Application certificates). +- The O-Cloud should support integration with trusted CAs for the issuance of certificates. +- The O-Cloud should support for various certificate management protocols like CMPv2 and ACME. +- The O-Cloud should implement secure and robust mechanisms for the generation of cryptographic keys. This includes using high-entropy sources for randomness and adhering to industry-standard cryptographic algorithms such as NIST SP 800-133 [i.48] and SOG-IS [i.49], ensuring the keys are of sufficient strength and quality. +- The O-Cloud should raise alarms and/or notifications if the secure storage space has exceeded the configured limits and more data cannot be stored. + +## 5.7 Solution #7: CMPv2 + +### 5.7.1 Description + +CMPv2 is described in RFC 4210 [i.5]. + +### 5.7.2 Impacts on Existing Interfaces and Functionality + +An O-RAN PNF, VNF, or CNF requiring a PKI certificate will need to support CMPv2. + +### 5.7.3 Solution Evaluation + +Current O-RAN specifications require CMPv2 for the management of the O-RU [i.10]. + +CMPv2 provides a solution for PKI certificate management protocol and procedures. + +CMPv2 provides the following functionality for O-RAN certificate management. + +- CMPv2 supports automatic certificate enrolment, rekey, and renewal procedures. +- CMPv2 provides built-in integrity protection and authentication. +- CMPv2 provides revocation support for VNFs and CNFs with the operation of Revocation Request/Response, Revocation Announcement and CRL Announcement. This support allows for an authorized orchestrator to revoke a certificate for a VNF or CNF before it is removed. +- It is not recommended to have CMPv2 provide revocation support for a PNF for the following reasons: + - o Most Certificate Policies require a human review and authorization of revocation request due to the severity of consequences. + - o The revocation requests are typically submitted by humans rather than machines that own the certificates. Once a PNF is compromised, it cannot be relied upon to request revocation for its own certificate and other elements in a domain may not be able to make practical use of an automated CMPv2 revocation messaging. + - o Human operators may mistake an unapproved revocation request with an actual act of revocation and take pre-mature actions. + - o CRLs are better provided by CRL servers (either LDAP or HTTP access as stated in clause 6.1.1 of the 3GPP TS 33.310[i.2]) that simply act as web-servers with no trust authority. This provides much better scalability properties than an RA/CA responding to high volume of CMP requests for CRLs. +- An O-RAN PNF, VNF, or CNF can use CMPv2 protocol or out-of-band procedures to register at the CA/RA. +- An O-RAN PNF, VNF, or CNF can use CMPv2 protocol to initiate the certificate request to the CA/RA, and receive the certificate from the CA/RA in a secure and automated procedure. +- An O-RAN PNF, VNF, or CNF can use CMPv2 protocol to update the key and certificate to the CA/RA, and receive the renewed certificate from the CA/RA before the certificate expires in a secure and automated procedure. + +### 5.7.4 Potential Security Requirements + +Potential security requirements: + +- An O-RAN PNF, VNF or CNF requiring a PKI certificate should support CMPv2 as defined in RFC-4210 [i.5]. +- An O-RAN PNF, VNF, or CNF supporting CMPv2 should have the URL, FQDN, and/or IP address for the RA/CA pre-configured or configurable. The RA/CA are defined in RFC-4210 [i.5]. For an instance of a PNF being configurable, an O-RAN PNF can be configured with the IP address or FQDN of one or more Certification Authority (CA/RA) servers using DHCP Option 43 as specified in clause 4.2.2 of 3GPP TS 32.509 [i.8]. +- An O-RAN PNF, VNF, or CNF supporting CMPv2 should raise notification and/or alarm if any polling request (as defined in RFC-4210 [5] clause 5.3.22) sent to CMPv2 server fails. +- CRL servers (either LDAP or HTTP access as stated in clause 6.1.1 of the 3GPP TS 33.310[2]) should be used to check the revocation status of certificates. + - If the check for revocation status fails for any reason, e.g., connectivity to CRL server fails, or DNS resolution of CRL server fails, then an alarm should be raised to enable operator to take appropriate actions. +- Details of any revoked certificate should be updated in CRL servers by the operator's PKI. + - If, for some reason, this update fails, alarm and/or notifications should be raised to notify the operator. + +## 5.8 Solution #8: Vendor Root CA Certificate Renewal notification + +### 5.8.1 Description + +The PNFs using vendor-signed certificates for initial certificate enrolment shall raise a notification when vendor root CA certificate is about to expire in x days. The notifications are raised with severity increasing closer to expiration: As an example: + +- WARNING when the certificate expires within the threshold +- MINOR when the certificate expires within 1/3 of the threshold +- MAJOR when the certificate expires within 1/6 of the threshold +- CRITICAL when the certificate expires within 1/30 of the threshold or 3 days, whichever is largest. This severity is used also after certificate expiration. + +### 5.8.2 Impacts on Existing Interfaces and Functionality + +None. + +### 5.8.3 Solution Evaluation + +In many deployments, the validity periods of vendor root CA certificates are very long. Moreover, once a PNF is enrolled using vendor-signed certificates, the need for using vendor root CA certificates for authenticating PNFs is very rarely required. Such a scenario may only be necessary if a PNF deployed many years ago requires a factory recovery for some reason and is intended to be used as a fresh deployment after vendor root CA certificate expires. + +This solution proposes notifications (alarms) to be raised with increasing levels of severity as the expiry date of vendor root CA certificate approaches. Operators need to keep track of such notifications and ensure timely updates of vendor certificates if necessary in order to ensure no impacts on system availability. + +## 5.8.4 Potential Security Requirements + +It is recommended that PNFs which use vendor-signed certificates for initial certificate enrolment monitor the expiry of the root CA certificate used to sign the certificate. When the expiry of the vendor root CA certificate is approaching, PNFs can raise notifications (alarms) with increasing levels of severity as the expiry date gets closer. + +## 5.9 Solution #9: Mitigating the risk of system overload due to bulk certificate updates + +### 5.9.1 Description + +This solution proposes an optional Certificate Update Orchestrator (CUO), which monitors various possible triggers for certificate updates, and orchestrates the certificate updates in a staggered manner in order to prevent potential service outage during simultaneous certificate updates for a large number of NFs (PNFs/CNFs/VNFs). Operators may implement such an orchestrator in their datacenters where NFs are hosted. In some implementations, this may be implemented as an application running in the datacenter where SMO is hosted, or in the O-Cloud. + +Figure 5-11 illustrates a possible implementation of CUO, showing the interfaces it may use. Implementations of CUO may vary, but this application should include the following functionalities in order to mitigate the risks detailed in Key Issue #13. + +- CUO schedules the required certificate updates in various network functions (physical as well as virtual) in a staggered manner. + - The schedule can be derived in a manner that services or functions related to neighboring cells do not update the certificates simultaneously. This can ensure that the connected UEs will have at least one RL, and end-user service experience is not degraded due to any certificate updates. + - Time of initiation of certificate update in every network function can be planned and executed according to this schedule +- CUO monitors and predicts the time required for updating certificates in various network functions + - it maintains an internal database where the past records of time taken for certificate updates are stored + - this database can be used in order to train ML algorithms for predicting the time required for updating certificates +- CUO also monitors and predicts the need for certificate renewals due to expiry, as well as updates due to revocation +- CUO coordinates with SON/RIC in order to increase the coverage of neighboring cells when certificate updates are performed on a specific cell. This can ensure zero impacts on end-user service experience during certificate updates. +- CUO monitors the network performance parameters during the certificate update procedure executions, and reinforces the analytics to derive continuously enhanced scheduling for certificate updates +- CUO monitors the network performance parameters and considers lower network traffic for initiating and scheduling certificate update procedures. + +![Figure 5-11: Certificate Update Orchestrator (CUO) diagram showing interactions between various network components.](958ec48f78723ce7eab31b4f417b6f6c_img.jpg) + +``` + +graph TD + OAF[Operator / Automation Function] -- "Triggers Bulk Certificate Updates" --> CUO + NMS[NMS] -- "Network Performance Measurements" --> CUO + NMS -- "Alarms Indicating Certificate About to Expire" --> CUO + CUO -- "Certificate Revocation" --> CRL[CRL / OCSP] + CUO -- "CA Announcement about Certificate Revocation" --> CARA[CA / RA] + CUO -- "SON Coordinated Certificate Update Execution" --> SON[SON / RIC] + CUO -- "Certificate Updates ACK" --> NF[Network Functions Physical OR Virtual] + NF -- "Certificate Update Triggers" --> CUO + NF -- "Coverage Coordination for certificate updates" --> SON + NF -- "Certificate Update procedure execution" --> CARA + CUO --- CUODB[(CUO DB)] + +``` + +The diagram illustrates the Certificate Update Orchestrator (CUO) and its interactions with various network components. The CUO is the central orchestrator, containing a CUO DB. It receives triggers for bulk certificate updates from the Operator / Automation Function and network performance measurements and alarms from the NMS. The CUO manages certificate revocation, sending updates to the CRL / OCSP and announcements to the CA / RA. It also coordinates certificate updates with the SON / RIC and triggers updates to the Network Functions (Physical OR Virtual). The Network Functions provide coverage coordination for certificate updates to the SON / RIC and execute the certificate update procedure, sending triggers back to the CUO and announcements to the CA / RA. + +Figure 5-11: Certificate Update Orchestrator (CUO) diagram showing interactions between various network components. + +Figure 5-11: Certificate Update Orchestrator + +## 5.9.2 Impacts on Existing Interfaces and Functionality + +None. + +## 5.9.3 Solution Evaluation + +This solution provides details of possible implementations which can help operators ensure that automated certificate management does not lead to un-intentional service outages in the live network. Such applications can be implemented by the operator and deployed in datacenters hosting the SMO, or in the O-Cloud, enabling easy access of data required for certificate update orchestration. + +Any automated certificate management system would benefit from avoiding simultaneous certificate updates for several network entities. This can be followed as a guideline. + +## 5.9.4 Potential Security Requirements + +None. + +## 5.10 Solution #10: Usage of PSK/Refnum for Initial Certificate Enrolment for PNFs + +### 5.10.1 Description + +This solution addresses key issue #2 of this TR. As described in RFC 4210 [i.5] Section 4.2.2.2 Basic Authenticated Scheme, Initial Authentication Key (IAK) and reference value can be used for initial certificate enrolment using CMPv2. In this document, IAK is referred to as PSK (Pre-shared Key) and reference value is referred to as Refnum. + +For PNFs, operators and vendors need to establish offline (out-of-band) secure methods in order to pre-provision PSK and Refnum values in PNFs which are planned to be newly deployed. The out-of-band methods may be automated, and clause 4.1 of this Technical Report can be referenced for any such automation. + +- PSK is used to sign the CMPv2 certification request, which is the first message sent from the PNF after initial deployment in the live network. PNF sends this request to operator's PKI using pre-configured network details of operator's PKI. +- The integrity of CMPv2 certification request is verified by the operator's PKI using the PSK. Also, operator's PKI verifies proof of possession of Refnum value which is included in the certification request. +- After successful verification of CMPv2 certification request, as per previous step, subsequent procedure is followed according to RFC 4210 Section 4.2.2.2 Basic Authenticated Scheme. +- Upon successful completion of PSK/Refnum based initial enrolment, the newly deployed PNF receives the operator's CA signed certificate, which is used for all subsequent establishment of secure connections with operator's PKI. + - PSK/Refnum values should not be used for any communications after initial enrolment. + - If a factory recovery is required, new PSK/Refnum values should be provisioned by the operator. + +## 5.10.2 Impacts on Existing Interfaces and Functionality + +No new impacts identified by this solution. + +## 5.10.3 Solution Evaluation + +This solution ensures backward compatibility for PNFs using PSK/Refnum based initial certificate enrolment. + +## 5.10.4 Potential Security Requirements + +Any offline or out-of-band PSK/Refnum generation and distribution systems implemented by the operator should ensure that no rogue PNF can obtain valid PSK/Refnum values. + +# 5.11 Solution #11: Certificate renewal procedure + +## 5.11.1 Description + +There are two possible scenarios when certificate renewal is required for any network function in O-RAN: + +1. Certificate is about to expire in near future +2. NF is initialized but has an already expired certificate. + +### 5.11.1.1 Certificate is about to expire in near future + +As mentioned in key issue #42, in order to ensure that there is no service un-availability due to certificate expiry, certificates should be automatically renewed with sufficient time before expiry. + +This solution proposes the following: + +- Operators can define a certificate renewal strategy, which could depend on the number of days to expiry or depending upon the alarm severity. Operators may also want to define a strategy for staggered certificate renewals. +- When any certificate is about to expire in the near future, associated NF (PNF/CNF/VNF) sends alarms to NMS. + - There can be multiple alarms with different severity. For example, if a certificate is about to expire on 30th day a Minor alarm is raised, if a certificate is about to expire on 15th day a Major alarm is raised, and when there are less than 5 days remaining for the certificate expiry a Critical alarm is raised. + +- NOTE that when a higher severity alarm is raised for the same certificate expiry, the lower severity alarm should be automatically cleared. +- Automated certificate management system monitors these alarms and schedules certificate updates using CMPv2 protocol. + +![Sequence diagram illustrating the Certificate renewal procedure. The diagram shows interactions between PNF/CNF/VNF, Service Management Orchestrator, Automated Certificate Management OR Certificate Update Orchestrator, Operator's PKI, and Operator. The process starts with the Operator defining a certificate renewal strategy (Step 1). The Automated Certificate Management system registers for receiving certificate expiry related alarms notifications (Step 2). A fault notification about certificate expiry approaching is received (Step 3). The Automated Certificate Management system sends a certificate expiry approaching alarm notification (Step 4). The system checks for the certificate renewal strategy (Step 5). Finally, the system triggers certificate renewal or schedules the renewal (Step 6). A note explains that operators can define a strategy, for example, renew certificates if expiry date is after X days, OR, schedule renewals according to the alarm severity. Staggering strategy may also be defined. Another note states that automated certificate management can trigger the renewal of certificates in a staggered manner to avoid system overload during bulk renewals. The bottom part of the diagram shows the CMPv2 based certificate renewal procedure involving the same entities.](9c8a8a87d6566b6a82a2e59f7c5f55d4_img.jpg) + +``` + +sequenceDiagram + participant PNF as PNF/CNF/VNF + participant SMO as Service Management Orchestrator + participant ACM as Automated Certificate Management +OR Certificate Update Orchestrator + participant OPKI as Operator's PKI + participant Operator as Operator + + Operator->>ACM: 1 Define certificate renewal strategy + Note over ACM: Operators can define a strategy, for example, +renew certificates if expiry date is after X days, +OR, schedule renewals according to the alarm severity. +Staggering strategy may also be defined. + ACM->>SMO: 2 Register for receiving certificate +expiry related alarms notifications + PNF-->>SMO: 3 Fault Notification about +Certificate expiry approaching + SMO-->>ACM: 4 Certificate expiry approaching +alarm notification + ACM->>ACM: 5 Check for certificate +renewal strategy + ACM->>PNF: 6 Trigger Certificate renewal or schedule the renewal + Note over ACM: Automated certificate management can trigger the +renewal of certificates in a staggered manner to avoid +system overload during bulk renewals. + Note over PNF, SMO, ACM, OPKI, Operator: CMPv2 based certificate renewal procedure + +``` + +Sequence diagram illustrating the Certificate renewal procedure. The diagram shows interactions between PNF/CNF/VNF, Service Management Orchestrator, Automated Certificate Management OR Certificate Update Orchestrator, Operator's PKI, and Operator. The process starts with the Operator defining a certificate renewal strategy (Step 1). The Automated Certificate Management system registers for receiving certificate expiry related alarms notifications (Step 2). A fault notification about certificate expiry approaching is received (Step 3). The Automated Certificate Management system sends a certificate expiry approaching alarm notification (Step 4). The system checks for the certificate renewal strategy (Step 5). Finally, the system triggers certificate renewal or schedules the renewal (Step 6). A note explains that operators can define a strategy, for example, renew certificates if expiry date is after X days, OR, schedule renewals according to the alarm severity. Staggering strategy may also be defined. Another note states that automated certificate management can trigger the renewal of certificates in a staggered manner to avoid system overload during bulk renewals. The bottom part of the diagram shows the CMPv2 based certificate renewal procedure involving the same entities. + +**Figure 5-12: Certificate renewal procedure** + +### 5.11.1.2 NF is initialized but has an already expired certificate + +If any NF is already initialized but has an expired certificate, it will fail to establish any secure connections. In this scenario, a Critical alarm should be raised frequently for the same until the certificate gets renewed. For example, one critical alarm can be raised per day and it can trigger the operator to obtain a new certificate sooner. The provisioning of updated certificates needs to be done offline. Until such time that the NF gets a renewed certificate, the NF should not be allowed to establish connection to the network. + +### 5.11.2 Impacts on Existing Interfaces and Functionality + +None. + +### 5.11.3 Solution Evaluation + +This solution addresses Key Issue #42. + +## 5.11.4 Potential Security Requirements + +Network management system should provide alarms/notifications to automated certificate management systems alerting about the certificates about to expire in the near future. + +Automated certificate management system should monitor the expiry time of certificates used by all network functions and ensure that the certificates are renewed automatically before the expiry. + +If, for some reason, the certificates for NF(s) expire without getting renewed, Critical alarms should be raised till such a certificate gets renewed. Also, NF(s) with such expired certificates should not be allowed to establish connections with the O-RAN network. + +## 5.12 Solution #12: Certificate Profile for O-RAN TLS Entity + +### 5.12.1 Description + +This solution addresses key issue #33 of the TR. The solution addresses specific certificate profiling requirements for elements, interfaces and systems expressly defined in O-RAN. + +#### 5.12.1.1 Certificate Profiling Requirements for TLS Entity + +The present clause defines the certificate profile requirements for the O-RAN nodes that use the TLS protocol for secured communication in the O-RAN network. The nodes involved and the interfaces are described in the table below. The present clause addresses the certificate profile requirements for the TLS end entity that behave either as client, server or both. + +| Use Case | Interface | Nodes involved | Security Mechanism | +|----------|-----------------------------|---------------------------------------------------|---------------------------------------------------| +| 1 | Open Front Haul(M-Plane) | O-RU and O-DU /SMO | mTLS, SSHv2, FTPES [i.e, O-RU becomes the client] | +| 2 | A1 Interface | Near-RT RIC and Non-RT-RIC | mTLS | +| 3 | Open Front Haul (CUS-Plane) | O-DU and O-RU | IEEE 802.1X with EAP-TLS | +| 4 | O1 | SMO and O-RAN Management Elements | mTLS | +| 5 | O2 | SMO and O-Cloud | mTLS | +| 6 | E2 | Near-RT RIC (xApps) and O-CU-CP and O-CU-UP | NDS/IP(IPsec) or DTLS | +| 7 | F1 | O-CU-CP and O-DU (F1-C)
O-CU_UP and O-DU(F1-U) | NDS/IP(IPsec) or DTLS | + +- The architecture for issuing TLS client and server certificates is as per 3GPP 33.310 [i.2] clause 5.1.1.2. TLS certificates will be directly signed by the CA in the operator domain that the entity belongs to. +- The common rules for all certificates defined in 3GPP33.310 [i.2], clause 6.1.1, clause 6.1.3.a will apply to this present clause. +- All certificates used during the enrolment process of O-RAN entities will follow the requirements given in clause 4.X.1.3 of the present document. + +- The CA-browser forum [i.20] has the following requirement for the certificate operational and key usage periods. Certificates issued on or after 1 September 2020 should not have a Validity Period greater than 397 days. +- **SubjectAltName :** + - According to RFC 5280[i.13], subjectAltName can be an Internet electronic mail address, a DNS name, an IP address, and a Uniform Resource Identifier (URI). As per RFC 6125[i.18], an application service can be identified by a name or names carried in the subject field (i.e., a CN-ID) and/or in one of the following identifier types within subjectAltName entries (DNS-ID, SRV-ID, URI-ID). + - RFC 6066 [i.17], which is applicable to TLS 1.2, defines that currently, only server names supported in SNI extension to TLS are DNS hostnames where "HostName" contains the fully qualified DNS hostname (FQDN) of the TLS server. RFC 6066 [i.17] also defines that literal IPv4 and IPv6 addresses are not permitted in "HostName". In practice, this means that at least one subjectAltName attribute with FQDN is to be included in server-side TLS end-entity certificates and subjectAltName will not contain only IP address in TLS server certificates. +- **Extensions:** + - Mandatory critical key usage: + - digitalSignature for both TLS client and Server certificates. This applies for RSA signature certificate, ECDSA signature certificate, or DSA signature certificate. + - According to TLS1.3 RFC 8446 [i.15] key agreement may be used for Diffie-Hellman certificates. This applies for the ECDH certificate, DH certificate. + +Optional and non-critical TLS Feature Extension: RFC7633[i.19] defines a certificate extension that indicates that clients expect stapled OCSP responses with a value of "status\_request(5)" for the certificate and aborts the handshake ("hard-fail") if such a response is not available. + +As per RFC 9325 for the common use cases of public key certificates in TLS, servers ought to support the following as a best practice: OCSP RFC 6960 [i.26] and OCSP stapling using the status\_request extension defined in RFC 6066[i.17] The exact mechanism for embedding the status\_request extension differs between TLS 1.2 and 1.3. As a matter of local policy, server operators may request that CAs issue must-staple [i.19] certificates for the server and/or for client authentication. + +Certificate Policies: A certificate policy (CP) is a designated set of rules that defines the applicability of a certificate to a particular community or a class of application with common security requirements. A CP is represented in a certificate by an "Object Identifier" (OID). The process of crafting a certificate policy can be derived from the guidelines defined in IETF RFC 3647[i.27]. + +## 5.12.2 Impacts on Existing Interfaces and Functionality + +No new impacts were identified by this solution. + +## 5.12.3 Solution Evaluation + +The following table defined below captures the certificate profile for the TLS end entity (Client and Server). + +| O-RAN TLS Client and Server Certificate Profile | | +|-------------------------------------------------|------------------------------------------------------------------| +| Version | v3 | +| Serial Number | Must be Unique Positive Integer in the context of the issuing CA | + +| Subject DN | |

(C=<country>), O=<Organization Name>, CN=<Some distinguishing name>. Organization and CN can be in UTF8 format. Note that C is optional element.

cn=<hostname>, (ou=<servers>), dc=<domain>, dc=<domain>. Note that ou is an optional element.

| | +|-------------------------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Validity Period | | 1 year or less | | +| Signature | | See clause 6.1.1 of 3GPP 33.310[i.2] for the list of supported signature algorithms. | | +| Subject Public Key Info | | See clause 6.1.1 of 3GPP 33.310[i.2] for the list of supported public key types. | | +| Extensions | Mandatory | Criticality | Value | +| keyUsage | TRUE | TRUE | digitalSignature for TLS clients and servers | +| extendedKeyUsage | FALSE | FALSE | id-kp-clientAuth TLS clients | +| | | | id-kp-serverAuth for TLS servers | +| | | | Entities that may be both client and server will have both OIDs set. | +| certificatePolicies | FALSE | FALSE | If added, then it should be populated with a CP object identifier(OID). These OIDs correspond to specific policies established by the certificate issuer. | +| authorityKeyIdentifier | FALSE | FALSE | This is same as the subjectKeyIdentifier of the Issuer's certificate. CA utilizes the method as defined in section 2 of RFC 7093[i.24]. | +| subjectKeyIdentifier | FALSE | FALSE | This is calculated by the issuing CA utilizing method as defined in section 2 of RFC 7093[i.24]. | + +| | | | | +|-----------------------|-------|-------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| cRLDistributionPoint | TRUE | FALSE |

distributionPoint

According to RFC 5280 [i.13] this indicates if the CRL is available for retrieval using access protocol and location with HTTP URI or LDAP.

| +| subjectAltName | TRUE | TRUE |

Clause 4.12.1.1 details the use of subjectAltName in TLS client and Server certificates.

| +| authorityInfoAccess | FALSE | FALSE |

id-ad-caIssuers

According to RFC 5280 [i.13] id-ad-caIssuers describes the referenced description server and the access protocol and location, for example, using one or multiple HTTP and/or LDAP URIs. The referenced CA issuers description is intended to aid certificate users in the selection of a certification path that terminates at a point trusted by the certificate user.

| +| | | |

id-ad-ocsp

According to RFC 5280 [i.13] id-ad-ocsp defines the location of the OCSP responder using HTTP URI.

| +| TLS feature extension | FALSE | FALSE |

id-pe-tlsfeature: "status_request(5)"

This can be used according to RFC 7633 [i.19] to prevent downgrade attacks that are not otherwise prevented by the TLS protocol; RFC 7633[i.19] also defines a certificate extension that indicates that clients expects stapled OCSP responses with a value of "status_request(5)" for the certificate and aborts the handshake ("hard-fail") if such a response is not available.

| + +## 5.12.4 Potential Security Requirements + +The TLS entity certificates should adhere to the certificate profile outlined in clause 5.12.3, based on their respective roles. The CA responsible for handling the certificate signing request should ensure compliance in accordance with the certificate profile specified in clause 5.12.3. + +## 5.13 Solution #13: Identifying RA and CA as separate logical entities with flexible deployment options + +### 5.13.1 General Description + +This solution addresses Key Issue #1. + +Reference : RFC 4210 [i.5] Appendix A : + +The reasons that justify the presence of an RA can be split into those that are due to technical factors and those which are organizational in nature. + +- If hardware tokens are in use, then not all end entities will have the equipment needed to initialize these; the RA equipment can include the necessary functionality (this may also be a matter of policy). + - NOTE: This aspect may not be directly related to certificate management, and hence not important for this study. +- Some end entities may not have the capability to publish certificates; again, the RA may be suitably placed for this. +- The RA will be able to issue signed revocation requests on behalf of end entities associated with it, whereas the end entity may not be able to do this (if the key pair is completely lost). + +Some of the organizational reasons that argue for the presence of an RA are the following. + +- It may be more cost effective to concentrate functionality in the RA equipment than to supply functionality to all end entities (especially if special token initialization equipment is to be used). +- Establishing RAs within an organization can reduce the number of CAs required, which is sometimes desirable. +- RAs may be better placed to identify people with their “electronic” names, especially if the CA is physically remote from the end entity. + - NOTE: Authenticating a human with a certificate is outside the scope of O-RAN, and therefore, this point is not relevant for this study. +- For many applications, there will already be in place some administrative structure so that candidates for the role of RA are easy to find (which may not be true of the CA). + +Based on the above description from RFC 4210 [i.5], it is recommended that operators assess the organizational policies and requirements for making a decision on whether or not, there is a need for having RA and CA deployed separately for O-RAN. + +From O-RAN perspective, considering PNFs, CNFs and VNFs as “end entities” to whom certificates need to be issued by operator’s CA, a separate RA can be considered for the following scenarios: + +1. For registration of xApps, Near-RT RIC can act as RA +2. For registration of rApps, Non-RT RIC can act as RA +3. Similarly, for registration of PNFs, RA may be hosted in SMO. +4. As an alternative deployment, RA can be hosted in O-Cloud and it can cater to registration of all PNFs/CNFs/VNFs + +## 5.13.2 Impacts on Existing Interfaces and Functionality + +None. + +## 5.13.3 Solution Evaluation + +This solution addresses Key Issue #1. + +## 5.13.4 Potential Security Requirements + +From O-RAN standardization point of view, RA and CA should be considered as separate logical entities. Operator may decide on deploy these entities in an integrated manner or separately. + +## 5.14 Solution #14: Securing Root CA Private Key + +### 5.14.1 General Description + +Solution #14 addresses Key Issue #20 Secure Storage of Trust Anchors and Private Keys. + +Securing the root CA private key is critical for the integrity of Public Key Infrastructure (PKI). A compromised root CA private key can lead to unauthorized certificate issuance, enabling identity spoofing and undermining trust in the entire PKI ecosystem. To secure root CA private keys, it's essential to maintain Root CA offline as a security best practice. + +#### **Importance of maintaining Root CA offline** + +The Primary objective of keeping the root Certificate Authority (CA) offline is to secure the private key associated with the root CA. The root CA private key security is critical because it is used to sign certificates issued by intermediate or Subordinate CAs, and its compromise could lead to fraudulent or unauthorized certificate issuance, impacting the trust of the O-RAN operator public key infrastructure. + +By maintaining the root CA offline, the private key is protected from various threats and unauthorized access, and thereby enhancing the security of the PKI infrastructure. + +Keeping the root CA offline, often referred to as “offline root CA”, means that private key of the root Certificate Authority (CA) is stored on a system that is not connected to any network or the internet. It is physically isolated from other systems and kept in a secure, air-gapped environment. This isolation reduces the risk of the root CA private key being exposed to online threats and unauthorised access and enhancing the security and trustworthiness of the PKI in O-RAN systems. + +The root CA needs to be online only during its initial setup and when issuing certificates for intermediate or Subordinate CAs. Once these intermediate or subordinate CAs certificates are signed, the root CA can be taken offline and stored securely. The root CA serves as a trust anchor for the PKI, and its primary role is to issue certificates for subordinate or intermediate CAs. Subordinate or Intermediate CAs then handle the issuance of certificates to O-RAN VNFs/CNFs, while root CA remains securely offline to maintain PKI integrity. + +Note: while it's common for a root CA's private key to be stored in HSM for added security, the term “root CA offline” refers to the network connectivity of the root CA system, not the specific use of an HSM. HSM provides additional layers of security by storing the private key in tamper-resistant hardware, but it doesn't directly affect the network connectivity status of the root CA system. [i.7] + +### 5.14.2 Impacts on Existing Interfaces and Functionality + +None. + +### 5.14.3 Solution Evaluation + +This solution addresses Key Issue #20. + +### 5.14.4 Potential Security Requirements + +From O-RAN standardization point of view, it's recommended to maintain Root CA offline status. + +Note: This recommendation applies only if Private CA uses intermediate CAs. + +## 5.15 Solution #15: Certificate enrolment for new NF Deployment using CMPv2 + +### 5.15.1 General Description + +Figure 5-13 illustrates the steps performed to configure enrolment certificate for new NF Deployment. The enrolment certificate shall be used for secured communication between SMO and Cloudified NF. The below procedure is specified as part of Instantiate Network Function on O-Cloud in clause 3.2.1 of ORAN TS Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN [i.52]. + +| Use case stage | Evolution / specification | <> Related use | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------| +| Goal | Provisioning enrolment certificate for new NF Deployment to perform initial configuration | | +| Actors and Roles |

NFO Service Consumer - Any service consumer allowed to consume NFO services [i.52];

SMO -A Service Management and Orchestration framework [i.51];

NFO – Network Function Orchestration [i.51];

OAM Functions – Operations, Administration and Maintenance function [i.51] ;

Operator PKI- Operator Public Key infrastructure;

O-Cloud-Cloud platform that provides O-RAN standardized interfaces, hosting O-RAN defined software components [i.52];

Cloudified NF- A RAN Network Function software that is deployed in the O-Cloud via one or more NF Deployments [i.52];

NF Deployment - A software deployment on O-Cloud resources that realizes all or part of a Cloudified NF [i.52];

End Entity: user of PKI certificates and/or end user system that is the subject of a certificate [i.13];

| | +| Pre-conditions |

i. NFO has credentials to communicate with PKI.

ii. Certificate Authority to issue the NF Certs to End Entity which is created in PKI.

iii. All End Entity associated trust domains are already created in PKI.

| | +| Begins when | New NF is ready for deployment. | | +| Step 1 (M) | NFO Service Consumer requests to NFO to instantiate new NF Deployment on the O-Cloud. | | +| Step 2 (M) | NFO invokes Operator PKI via the vendor specific PKI interface to create End Entity associated to NF Deployment via O1 interface. | | +| Step 3(M) |

Operator PKI configures the End Entity and responds with enrolment data to NFO.

Enrolment data consists of: CMP details associated with provisioned End Entity, including one-time password in section 2.2.3 of RFC 7030 [i.32]; Root CA certificate details.

| | +| Step 4 (M) | NFO incorporates the enrolment data in NF Deployment initial configuration (including PKI server details). NF Deployment should consume these data to request certificate and CA trust certs towards operator PKI. | | +| Step 5 (M) | NFO triggers NF Deployment in O-Cloud using O2-dms interface, this trigger may be in several steps, for instance secrets shall be shared in secured way before actual NF Deployment starts. | | +| Step 6 (M) | O-Cloud creates new NF Deployment instance. | | +| Step 7(O) | The NFO receives information about the success/failure of the NF Deployment instantiation in the O-Cloud. | | +| Step 8(M) | NF Deployment requests Operator PKI using the initial configuration with received one-time password to enroll certificates. | | +| Step 9(M) | Operator PKI responds with enrolment certificate to the NF Deployment instance, including the trust anchors of the domains the node will communicate to. | | +| Ends when | Initial configuration and enrolment certificate is configured for the new NF Deployment. | | +| Exceptions | None identified | | +| Post-conditions | Trust established between the Cloudified NF and SMO. | | + +![Sequence diagram for Certificate enrolment for new NF Deployment. The diagram shows interactions between NFO Service Consumer, SMO (NFO, OAM), Operator PKI, O-Cloud, and Cloudified NF (NF Deployment). The process involves: 1. NF deployment request from NFO Service Consumer to NFO. 2. Create End Entity from NFO to OAM. 3. Return one-time password and PKI server details from OAM to NFO. 4. Update NF deployment for initial configuration from NFO to OAM. 5. NF deployment in O-Cloud via O2dms interface from NFO to O-Cloud. 6. NF deployment instance from O-Cloud to Cloudified NF. 7. NF deployment response (success/fail) from Cloudified NF to NFO. 8. Request Certificate (CMPv2) from Cloudified NF to Operator PKI. 9. Process CSR and send certificate from Operator PKI to Cloudified NF. Notes describe the NFO invoking Operator PKI via the vendor specific PKI interface to create End Entity, and the Operator PKI configuring the End Entity and responding with enrollment data to NFO. Enrollment data consists of: CMP details associated with provisioned End Entity, including one-time password; Root CA trust certificate details. Another note describes the NF Deployment requesting Operator PKI using the initial configuration with received one-time password to enroll certificates, and the Operator PKI responding the enrollment certificate to the NF Deployment instance.](515fd40b0496ecf9334edd56e11147c0_img.jpg) + +Sequence diagram for Certificate enrolment for new NF Deployment. The diagram shows interactions between NFO Service Consumer, SMO (NFO, OAM), Operator PKI, O-Cloud, and Cloudified NF (NF Deployment). The process involves: 1. NF deployment request from NFO Service Consumer to NFO. 2. Create End Entity from NFO to OAM. 3. Return one-time password and PKI server details from OAM to NFO. 4. Update NF deployment for initial configuration from NFO to OAM. 5. NF deployment in O-Cloud via O2dms interface from NFO to O-Cloud. 6. NF deployment instance from O-Cloud to Cloudified NF. 7. NF deployment response (success/fail) from Cloudified NF to NFO. 8. Request Certificate (CMPv2) from Cloudified NF to Operator PKI. 9. Process CSR and send certificate from Operator PKI to Cloudified NF. Notes describe the NFO invoking Operator PKI via the vendor specific PKI interface to create End Entity, and the Operator PKI configuring the End Entity and responding with enrollment data to NFO. Enrollment data consists of: CMP details associated with provisioned End Entity, including one-time password; Root CA trust certificate details. Another note describes the NF Deployment requesting Operator PKI using the initial configuration with received one-time password to enroll certificates, and the Operator PKI responding the enrollment certificate to the NF Deployment instance. + +Figure 5-13 Certificate enrolment for new NF Deployment + +## 5.15.2 Impacts on Existing Interfaces and Functionality + +None. + +## 5.15.3 Solution Evaluation + +This solution addresses Key Issue #6: Initial Certificate Enrolment for new NFs. + +## 5.15.4 Potential Security Requirements + +**REQ-SEC-CMF-VNF\_CNF-X:** SMO shall configure all the initial information for certificate enrolment procedure for NF Deployment. + +## 6 Conclusions + +### 6.1 Key Issue #41: CMPv2 + +The following proposed normative specifications support PKI certificate management protocol and procedures for an O-RAN PNF, VNF, or CNFs using PKI certificates: + +An O-RAN PNF, VNF or CNF requiring a PKI certificate shall support CMPv2 as defined in RFC-4210 [i.5]. + +An O-RAN PNF, VNF, or CNF supporting CMPv2 shall have the URL, FQDN, and/or IP address for the RA/CA pre-configured or configurable. The RA/CA are defined in RFC-4210 [i.5]. For an instance of a PNF being configurable, an O-RAN PNF can be configured with the IP address or FQDN of one or more Certification Authority (CA/RA) servers using DHCP Option 43 as specified in clause 4.2.2 of 3GPP TS 32.509 [i.8]. + +### 6.2 ACME as Optional Certificate Management Protocol + +An O-RAN network function requiring a PKI certificate may optionally support ACME as defined in RFC-8555 [i.42] in addition to CMPv2. This is especially beneficial for use with O-Cloud implementations that currently often use ACME as a certificate management protocol via the ACME plugin for the cert-manager component of Kubernetes which is a common technology for dynamic o-cloud deployments. + +The ACME solution as described in clause 4.4 addresses the following key issues: + +1. Key Issue #37: Lightweight solution (refer to clause 5.2 for details) +2. Key Issue #38: Interoperability (refer to clause 5.3 for details) + +### 6.3 Usage of PSK/Refnum for initial certificate enrolment for PNFs, CNFs and VNFs + +This clause presents conclusions for solutions #1 and #10. + +As described in RFC 4210 [i.5] Section 4.2.2.2 Basic Authenticated Scheme, Initial Authentication Key (IAK) and reference value can be used for initial certificate enrolment using CMPv2. In this document, IAK is referred to as PSK (Pre-shared Key) and reference value is referred to as Refnum. + +For backward compatibility, PSK/Refnum-based initial certificate enrolment can be used for PNFs. + +Based on the potential security requirements proposed in clause 4.1.4 and 4.10.4, the following normative security requirement can be added to the O-RAN security requirements specification: + +Any offline or out-of-band (automated or manual) PSK/Refnum generation, distribution and provisioning systems implemented by the operator should ensure that no rogue PNF/CNF/VNF can obtain valid PSK/Refnum values. + +### 6.4 Vendor root CA certificate renewal notification + +This clause proposes conclusions for solution #8, which addresses key issue #8. + +A new security requirement can be added in O-RAN security requirements specifications for the potential security requirement proposed in clause 5.8.4 of this Technical Report. + +Also, it is recommended that operators monitor notifications which may be raised when vendor root CA certificate is about to expire and take appropriate actions to ensure that there is no impact on system availability. + +Proposed new security requirement: + +PNFs which use vendor-signed certificates for initial certificate enrolment should monitor the expiry of the vendor root CA certificate used to sign the certificate. When the expiry of the vendor root CA certificate is approaching, PNFs should raise notifications (alarms) with increasing levels of severity as the expiry date gets closer. + +## 6.5 Initial certificate enrolment for PNFs using vendor certificates + +This clause proposes conclusions for solution #5, which addresses Key Issue #3 and Key Issue #4. + +New security requirements can be added in O-RAN security requirements specifications for the potential security requirements proposed in clause 5.5.4 of this Technical Report. + +## 6.6 Certificate renewal procedure + +This clause proposes conclusions for solution #11, which addresses key issue #42. + +New security requirement can be added in O-RAN security requirements specifications for the potential security requirements proposed in clause 5.11.4 of this Technical Report. + +## 6.7 RA and CA as separate logical entities + +This clause proposes conclusions for solution #13, which addresses key issue #1. + +No new security requirements are required for this because it is up to the operator to make a decision whether to deploy RA and CA as independent entities or in an integrated manner. + +## 6.8 EST as Optional Certificate Management Protocol + +An O-RAN element requiring a X.509 certificate may optionally support EST as defined in RFC-7030 [i.32] in addition to CMPv2. This is especially beneficial in scenarios where the environment does not require a complex PKI infrastructure for certificate management and also offers a practical solution in scenarios where an O-RAN network element lacks digital certificate bootstrapping or is missing CA information for enrolment. The EST solution as described in clause 5.3 addresses the following key issues: + +1. Key Issue #37: Lightweight solution (refer to clause 5.2 for details) + +## 6.9 Use of BRSKI in O-RAN + +No normative specifications are necessary for BRSKI as described in Solution #2, which address key issues #1, #2, #10, #37, #38, and #41. + +See Clause 5.2.3 Solution Evaluation for further information. + +## 6.10 Mitigating the risk of system overload due to bulk certificate update + +No normative specifications are necessary to address Solution #9, which addresses key issue #13. + +See Clause 5.9.3 Solution Evaluation for further information on best practices to mitigate the risk of system overload due to a bulk certificate update. + +## 6.11 Key Issue #20: Certificate Management and Secure Storage of Private Keys + +Following conclusions are made on the Key-Issue #20 “Certificate Management and Secure Storage of Applications Private Keys”: + +For the evaluation two different solution concepts will be considered. + +The first concept is the based on an O-Cloud platform hosting a ‘Secure Storage Resource Manager (SSRM)’. This SSRM is managing the interface to either the SW based or HW based secure storage solution. On the north-bound interface the SSRM is providing a common Secure Storage API that can be used by application to request service from the SSRM, while on the south-bound interface the SSRM is hiding the underlying method for key and file storage. The private key is never leaving the secure key storage and any service request that involves the private key is going via the SSRM. + +### 6.11.1 Evaluation and Assessment for local security module managed by SSRM within the O-Cloud + +Advantages: + +- Compliance Requirements: Certain regulatory frameworks may require the use of local security modules (e.g., HSM [i.6], [i.46]) for specific security controls. Utilizing a local security module can help meet compliance requirements. +- Reduced Dependency: By having a local security module, organizations reduce their reliance on external systems or services, providing greater control over key management. + +Considerations: + +- Higher Cost: Security modules are specialized devices and can be more expensive to acquire and maintain compared to using a KMS. +- Limited Scalability: Local security modules have finite capacity, and scaling may require additional security modules or infrastructure investments. +- Operational Complexity: Local security modules require dedicated management, configuration, and maintenance, which may add complexity to the overall O-Cloud architecture and administration. + +The second concept is based on a remote Key Management System (KMS). The KMS is external to the O-Cloud, which means it is located outside of the O-Cloud infrastructure. It is responsible for storing and managing private keys by an HSM and issuing key-encryption keys which are used to protect the secure storage volumes. + +### 6.11.2 Evaluation and Assessment for the KMS + +Advantages: + +- Key Lifecycle Management: KMS solutions often include features for key rotation, revocation, and auditing, enabling effective key lifecycle management. +- Integration with O-Cloud: KMS solutions offered by cloud service providers can seamlessly integrate with other cloud services, simplifying key management in O-Cloud. + +Considerations: + +- Dependence on External Service: Utilizing a KMS requires reliance on an external service, which may introduce dependencies and potential availability concerns. Organizations need to ensure proper backup and disaster recovery measures. +- Data Privacy: With a KMS, cryptographic key material is stored and managed by a third-party service. Organizations should consider the privacy implications and evaluate the trustworthiness of the KMS provider. + +### 6.11.3 Conclusion + +It is concluded to go for normative work based on the O-Cloud with local security modules managed by an embedded Secure Storage Resource Manager (SSRM). A local security module offers enhanced physical protection and security measures for cryptographic keys, making it a robust solution for safeguarding sensitive information within the O-Cloud infrastructure. + +**Rationale:** By using a local security module, it can be ensured that the cryptographic keys remain within the boundaries of the O-Cloud environment, reducing reliance on external services and enhancing control over key management. While a local HSM may introduce certain considerations such as cost, scalability, and operational complexity, the benefits of its enhanced security and compliance adherence can outweigh these factors in security-sensitive environments like O-Cloud. + +## 6.12 Cert Profile for O-RAN TLS Entity + +This clause proposes conclusions for solution #12, which addresses key issue #33. + +New security requirements can be added in O-RAN Protocol Specifications for the potential security requirements proposed in clause 5.12.4 of this Technical Report. + +The certificate profile defined in clause 5.12.3 of this Technical Report can be applied O-RAN NFs (PNF/VNF/CNF) and O-RAN interfaces that use the TLS protocol for establishing secured communication. + +## 6.13 Certificate enrollment for new NF Deployment using CMPv2 + +This clause proposes conclusions for solution #15, which addresses key issue #6. + +Based on the potential security requirements proposed in clause 5.15.4, the following normative security requirement can be added to the O-RAN security requirements and control specification: + +The certificate enrollment procedure for NF deployment defined in clause 5.15.1 of this Technical Report should be applied to O-RAN NFs (VNF/CNF) for establishing secure communication. + +## 7 Key Issues-Solutions mapping + +This clause contains the mapping of the proposed solutions to the key issues. + +**Table 7-1 Mapping of Key Issues to Solutions** + +| | Sol.
#1 | Sol.
#2 | Sol.
#3 | Sol.
#4 | Sol.
#5 | Sol.
#6 | Sol.
#7 | Sol.
#8 | Sol.
#9 | Sol.
#10 | Sol.
#11 | Sol.
#12 | Sol.
#13 | Sol.
#14 | Sol.
#15 | +|---------------|------------|------------|------------|------------|------------|------------|------------|------------|------------|-------------|-------------|-------------|-------------|-------------|-------------| +| Key issue #1 | | X | X | | X | X | | | | | | | X | | | +| Key issue #2 | X | X | X | | | | | | | X | | | | | | +| Key issue #3 | | | | | X | | | | | | | | | | | +| Key issue #4 | | | | | X | | | | | | | | | | | +| Key issue #5 | VOID | | | | | | | | | | | | | | | +| Key issue #6 | X | | | | | X | | | | | | | | | X | +| Key issue #7 | VOID | | | | | | | | | | | | | | | +| Key issue #8 | | | X | | | X | X | X | | | | | | | | +| Key issue #9 | VOID | | | | | | | | | | | | | | | +| Key issue #10 | | X | X | | | X | X | | | | | | | | | +| Key issue #11 | VOID | | | | | | | | | | | | | | | +| Key issue #12 | | | | | | | | | | | | | | | | +| Key issue #13 | | | | | | X | X | | X | | | | | | | +| Key issue #14 | VOID | | | | | | | | | | | | | | | +| Key issue #15 | VOID | | | | | | | | | | | | | | | +| Key issue #16 | VOID | | | | | | | | | | | | | | | +| Key issue #17 | VOID | | | | | | | | | | | | | | | +| Key issue #18 | | | | | | X | X | | | | | | | | | +| Key issue #19 | | | | | | X | X | | | | | | | | | +| Key issue #20 | | | | | | X | X | | | | | | | X | | +| Key issue #21 | | | | | | X | X | | | | | | | | | +| Key issue #22 | | | X | | | X | X | | | | | | | | | +| Key issue #23 | | | X | | | X | X | | | | | | | | | +| Key issue #24 | | | | | | | X | | | | | | | | | +| Key issue #25 | | | X | | | X | X | | | | | | | | | +| Key issue #26 | | | X | | | X | X | | | | | | | | | +| Key issue #27 | | | X | | X | X | X | | | | | | | | | +| Key issue #28 | | | X | | | X | X | | | | | | | | | +| Key issue #29 | | | X | | | X | X | | | | | | | | | +| Key issue #30 | | | X | | | X | X | | | | | | | | | +| Key issue #31 | VOID | | | | | | | | | | | | | | | +| Key issue #32 | VOID | | | | | | | | | | | | | | | +| Key issue #33 | | | X | | | X | X | | | | | X | | | | +| Key issue #34 | VOID | | | | | | | | | | | | | | | +| Key issue #35 | VOID | | | | | | | | | | | | | | | +| Key issue #36 | | | | | | X | X | | | | | | | | | +| Key issue #37 | X | X | X | X | X | | X | | | | | | | | | +| Key issue #38 | | X | | X | | | | | | | | | | | | +| Key issue #39 | | | X | | | | | | | | | | | | | +| Key issue #40 | VOID | | | | | | | | | | | | | | | +| Key issue #41 | | X | | | | | X | | | | | | | | | +| Key issue #42 | | | | | | | X | | | | X | | | | | +| Key issue #43 | X | | X | | | X | X | | | | | | | | | + +## Annex: + +### Change history/Change request (history) + +| Date | Revision | Doc status | Author | Description | +|------------|-----------|------------|--------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.02.22 | V01.00.01 | Draft | SFG | Document creation, template | +| 2022.03.08 | V01.00.02 | Draft | SFG | Updated template | +| 2022.04.12 | V01.00.03 | Draft | SFG | Added key issues generated by the CMF subworking group. | +| 2022.06.14 | V01.00.04 | Draft | SFG | Incorporated the following CRs:

RMI-2022.04.26-SFG-Certificate-management-CR-002

RMI-2022.05.10-SFG-Certificate-management-CR-003

NOK-2022.05.10-SFG-Certificate-management-Multiple certificates per interfaces - CR_03

NOK-2022.05.10-SFG-Certificate-management-merge of key issues 5 and 7-CR_02

NOK-2022.05.10-SFG-Certificate-management-Moving Key issues to Solutions-CR_01 | +| 2023.01.10 | V01.00.05 | Draft | SWG | Incorporated the following CRs:

ATT-2022.06.07- SFG-Certificate-management-architecture-CR_01-r2

NOK-2022.07.04-SFG-Certificate-management-vendor-cert-based-enrolment_CR_05-r8

NOK-2022.07.04-SFG-Certificate-management-PSK_Refnum-CR_04_r8

RMI.COM-2022.08.22-WG11-CR-0001-Certificate-Management-Study-on-ACME

ORA-2022.09.27-WG11-CR-0025-Certificate-Management-SecStorageHSMv04

ATT-2022.10.24-SFG-CMPv2-solution-CR_02-r1

NOK-ORA-2022.12.06-WG11-CR-0013-Certificate-Management-SecStorage_v01 | +| 2023.06.30 | V01.00.06 | Draft | SWG | Incorporated the following CRs:

DT-2023.01.31-SFG-TR-Certificate-Management-Framework-ACME-optional_v5

ERI-2023.01.25-WG11-CR0019-CertificateManagementFramework-TR-v01

NOK-2023.02.01-WG11-CR-0046-Certificate-management-Bulk_Updates_r2

NOK-2023.02.01-WG11-CR-0045-Certificate-management-PSK_Refnum | + +| | | | | | +|------------|-----------|-------|-----|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | |

NOK-2023.05.02-WG11-CR-0047-Certificate-management-Renewal-v01

SYM-2023.05.09-SFG-CR-0009-CertificateProfile_TechnicalReport_v07

| +| 2023.09.12 | V01.00.07 | Draft | SWG |

Incorporated the following CRs:

NOK-2023.07.06-WG11-CR-0084-Certificate-management-RA-CA-v03

AKA-2023.07.10-WG11-CR-0001-Align-Certificate-Management-terminology_v02

SYM-2023.06.27-SFG-CR-0019-CertificateProfile_TR_Conclusion_v03

WG11-2023.07.25-WG11-CR-0007-Key issue-Solutions mapping_v02

NOK-2023.07.06-WG11-CR-0085-Plug-and-connect-PNFs-v03

NOK-2023.08.07-WG11-CR-0099-BRSKI_v02

| +| 2023.10.24 | V01.00.08 | Draft | SWG |

WG11-2023.09.08-WG11-CR-0010-Key issues-1-to-11-42-43-v02

ATT-2023.09.12-WG11-CR-69-Solution-Evaluation-Reorganization

NOK-2023.09.08-0107-Key issue-Solutions mapping

WG11-2023.09.25-WG11-CR-0013-Key issues-12-to-25-v03

NOK-2023.08.07-WG11-CR-0106-KI28-PKI-Migration

NOK-2023.08.07-WG11-CR-0118-Solution-PKI-Migration-v2

SYM.AO-2023.08.22-WG11-CR-0022-CertificateManagement-EST_Protocol-v07

NOK-2023.10.17-WG11-CR-0117-Solution%231_Solution%2310_Updates

NOK-2023.10.17-WG11-CR-0119-Solution%238_Updates_v2

NOK-2023.10.17-WG11-CR-0120-Conclusions_Sol5_11_13

WG11-2023.09.25-WG11-CR-0014-Key issues-9 11 and 26-to-41-v01

| +| 2024.03.13 | V02.00 | Draft | SWG |

NOK-2023.06.20-WG11-CR-0083-Conclusion_on_Certificate-Management-SecStorage_v06

RMI-2023.10.17-WG11-CR-0013-Securing private keys_v2

ATT-2023.10.19-0070-Key-issue-Solutions-mapping-update

SYM.AO-2023.11.28-WG11-CR-0032-EST_Protocol_Conclusion-v03

ATT-2023.11.28-WG11-CR-0031-CertMgmtTR_KeyIssues33and36Updates-v3

| + +| | | | | | +|------------|--------|-------|------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | |

ATT-2023.12.19-WG11-CR-0032-CertMgmtTR_Conclusion_Solution2-v2

ATT-2023.12.19-WG11-CR-0033-CertMgmtTR_Conclusion_Solution9-v1

WG11-2024.01.08-WG11-CR-0021-CertMgmtTR_PSR_Solution6-v2

NOK-2023.10.17-WG11-CR-0138-Solution_8_Conclusion-correction

SYM-2024.01.30-WG11-CR-0041-CertificateProfile_Conclusion-v03

| +| 2024.06.26 | V03.00 | Draft | SWG |

NEC-2024.04.09-WG11-CR-0017-CertMgmtFrmk_Abbreviations_and_Acronyms_Updates-v1

ERI-2024.05.14.-WG11-CR0124-CertificateManagementFramework-KeyIssue40mapping-v01

ERI-2024.05.14-WG11-CR0126-CertificateManagementFramework-Subjectaltname-v02

ERI-2024.05.28-WG11-CR0133-CertificateManagementFramework-CertificateEnrolmentforNewCNF-v04

| +| 2024.11.04 | V04.00 | Draft | WG11 |

NOK-2024.07.12-WG11-CR-0175-CertMgmt-req-CRL-failure-alarms-v02

NOK-2024.07.12-WG11-CR-0176-CertMgmt-req-storage-space-alarms-v02

ERI-2024.06.25-WG11-CR0144-CertificateManagementFramework-Clause6.13Conclusion for solution5.15-v03

NOK-2024.09.16-WG11-CR-0197-CMPv2-polling-failure-alarms-v03

| \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/038812f771996e5ec6ecfe377a66d2e0_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/038812f771996e5ec6ecfe377a66d2e0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ca448140965e6b74ad21de10967be1345eaeb877 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/038812f771996e5ec6ecfe377a66d2e0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d596b636f7e3a864639eef9973fe4bf2de288b6cc0f317871024134901a5fff +size 114834 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/04343f5123f55639e4963a55d7eecd30_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/04343f5123f55639e4963a55d7eecd30_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9e7fe55c3e74a7cd05390eeee0228e57b0e1dafc --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/04343f5123f55639e4963a55d7eecd30_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:816adcefc1dbe80afb26ee6760df1ddc8fac5b5ba9b4d207ce2d92f7e8777fdc +size 4393 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/1e14c438d72178947accdb2929913590_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/1e14c438d72178947accdb2929913590_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..40d3bb7faf7baf52c9cfa9445b0719e5d75209b7 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/1e14c438d72178947accdb2929913590_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:72607d1586b6197b00547d9b9c7a4fd04569da6d8170973223ecefac7202cedc +size 28533 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7b84e262d2fc7e0b59b4101053a42526958b946a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e7bdaaf5aacb655dae815886fc7e68b08115ae4458078ccf72b022c81a0a12c +size 4142 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/203661b7f7e1a3bfe2aa34602f6984c9_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/203661b7f7e1a3bfe2aa34602f6984c9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..79916d98f2b426d339f29df18dca5870a73b7835 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/203661b7f7e1a3bfe2aa34602f6984c9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9f6c3e127d40897d0d3a19509c0894c9eb9def7a1a4a31b7159f0ed066db340a +size 4509 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/22d83a70a194ee454b2e949b047c02b5_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/22d83a70a194ee454b2e949b047c02b5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..383505e6fb926ec6fb44981967358df22c447d58 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/22d83a70a194ee454b2e949b047c02b5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84d80540a041e54f7db95ea4c1548b9ce7724f0725a8d786463b5dc7e9a9e64e +size 21986 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/36a87c0e365b478e3173c58c2c915b7d_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/36a87c0e365b478e3173c58c2c915b7d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..64086a4d244aa3db8b0677e77b789f740d9f4c5b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/36a87c0e365b478e3173c58c2c915b7d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ce3defd2f5798109734f8ce61fd1df9c7d34820ed350d272ad3c84b6036042d +size 4038 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/37289ad05957180b7fdd41db6386cf76_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/37289ad05957180b7fdd41db6386cf76_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e0f9dd4420796936e5c700eee8121f813e44c8d1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/37289ad05957180b7fdd41db6386cf76_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fe3e10e156cee1a06c1faca4aed19dee258f2769b30e2f68b631e88fbbbf3c5d +size 75848 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/37d86aea722a87033aab14333c50bd9c_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/37d86aea722a87033aab14333c50bd9c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..373c2dbc94f14e25191522bacc9e9e478c29f5c1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/37d86aea722a87033aab14333c50bd9c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e9275bfe8b18ac08815f0bf0542125d8e905795c3fb0e7daedefba4d2ed09c4 +size 75284 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/3f57a7cfbbec9f807595d918379bc92c_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/3f57a7cfbbec9f807595d918379bc92c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..459deef1f8ff371ac9b010201d90104793bf011e --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/3f57a7cfbbec9f807595d918379bc92c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:57722e3ad2c83e6e97e5d3cd96bdd41915b5f16da529ccce300894da56852b6a +size 41535 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/431075921161f0a1a78ee74670ecb6d6_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/431075921161f0a1a78ee74670ecb6d6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8a0a91f4448ac7f3e0f01fbb46777c0e1c8e3db9 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/431075921161f0a1a78ee74670ecb6d6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:772c27ffafd9dd382ba32a352e18dd0ab5e0b2dfdc109def0bd1b292e0852ed7 +size 4207 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/463cd4df73fa4fe65bb1efc7c143e8b7_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/463cd4df73fa4fe65bb1efc7c143e8b7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1ad8a246ad9834446dcc52b4a7c49a43b97966f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/463cd4df73fa4fe65bb1efc7c143e8b7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:164fd52a4730b9f546ad2d32745c6dfa125406958cc6fb19bde3d87d0b672997 +size 57818 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/5512bb9a76021bc6a412c58de682f1a9_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/5512bb9a76021bc6a412c58de682f1a9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e54abe7920c2a5e6f7a85b51f7945579043fa7fd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/5512bb9a76021bc6a412c58de682f1a9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dc97b92ef3342036b11ba1494e118d258af5a83eb084c26bd35546b9d3622f7a +size 92412 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/5f3ad2f36edbd22288f07995dbd0944a_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/5f3ad2f36edbd22288f07995dbd0944a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..da6acafda0dfbaa7c86ffadf4b1264c9b179a933 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/5f3ad2f36edbd22288f07995dbd0944a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:90fc190b03b4af1f474efd0eb084842214b6f2609eea6660a1e65ed3d1982d9f +size 39335 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/5f51fe277c7a63979a37743da8790e2b_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/5f51fe277c7a63979a37743da8790e2b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aaf45551742ebe022e3d140f49e41ccdf0915c7c --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/5f51fe277c7a63979a37743da8790e2b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9a32650606f79ff9d04bff392c86b6cfb72c6a0b274b2800e4a8fa751cfa813e +size 46170 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/62c919d77bbd7e96d4804f1fa0c7a34c_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/62c919d77bbd7e96d4804f1fa0c7a34c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbb183dc23a2e478306cd1e73396fe3adb651745 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/62c919d77bbd7e96d4804f1fa0c7a34c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ca258b99dec1c47d0eaff01a83d399a99d6f0c2da8322c2aa83ed73a3ab714ed +size 27897 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/63744c226c2e4bcadd07a120df3457da_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/63744c226c2e4bcadd07a120df3457da_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3bb931ff5a4261b8fdda3cd40d8edc56d70fee9 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/63744c226c2e4bcadd07a120df3457da_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:52e749004b67f9ebeecd6ea8b0e465b315fff63e6f5c5adbaec3eb31a0372ef5 +size 153944 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/6c015df514d9b4662a431f1a7fcb67cf_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/6c015df514d9b4662a431f1a7fcb67cf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..259b59aeccc8427563a1de01371bf821b30dea97 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/6c015df514d9b4662a431f1a7fcb67cf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d446426696e5882d35a19926f22e40f6279e8a64709189e1cfe714f0cf6766fd +size 24744 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/71816d3fa6de3d8c69938b0d50314faa_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/71816d3fa6de3d8c69938b0d50314faa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e536dac9c52819edd4174599e52e409111a0fef3 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/71816d3fa6de3d8c69938b0d50314faa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1ad45c4c48fef4071c65a226999f005bf2d0f87ae06fc2f17a0c2c708823443f +size 4349 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/7182eca90249220437ad6a5148439651_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/7182eca90249220437ad6a5148439651_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dd98d30df24c6f4b2b95331776ac95dc07dc1379 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/7182eca90249220437ad6a5148439651_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f1d143df42b95f21cb11db3e570b13fbab1c0b62940d6f6d7fa45b456a536ccf +size 62235 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/7f5f93e2f0ad459989e28fdfca1aaf1e_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/7f5f93e2f0ad459989e28fdfca1aaf1e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d853151b66e10815d80fca510c85e4e7e44eab67 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/7f5f93e2f0ad459989e28fdfca1aaf1e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a4bee67ec2d5a0c510ac870f290b2e85caa664f9f2662d0e89aeb1c4dc4d757f +size 34559 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/886f8f113a97c7b189a17a5c0cd355f4_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/886f8f113a97c7b189a17a5c0cd355f4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..23fd0df104c0f936a9d816dc93d5e9e324b0dddd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/886f8f113a97c7b189a17a5c0cd355f4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9521fb2190a0fba869279cf1c6acaccf47906b4d0c48d9eb30b1e8bc66a67450 +size 4270 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/8a1d72a3bca908ddaf09dc58d126457e_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/8a1d72a3bca908ddaf09dc58d126457e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..53a7837d7819e43b035a5e761512fae45dd8b14c --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/8a1d72a3bca908ddaf09dc58d126457e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4eba4b0bab46c4a2f29810ac83da310cd4b9e14144b6b1e0bbb51d06b02653a4 +size 18192 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/93b81487b65064c8f1b8b4fb90b5eef9_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/93b81487b65064c8f1b8b4fb90b5eef9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b95a4033033bbbc117d4aa9eb2d8e79b8f188893 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/93b81487b65064c8f1b8b4fb90b5eef9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b907bdf879730d502c4dd9fa97de370a4c998298ab67879dcedab1988a524c43 +size 4080 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/ac5187dbc3af0eebac759779de3ed5e5_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/ac5187dbc3af0eebac759779de3ed5e5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d8c83c3f9e0d4c6e598b633a32e437028baad69 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/ac5187dbc3af0eebac759779de3ed5e5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:392c0b51ac5fb99cff0ae54457c2edbd2a18bf083f329ad38526188c9b10a000 +size 4188 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/b1ece3c05d1bc8678bbe34e666d99de5_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/b1ece3c05d1bc8678bbe34e666d99de5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2ef58564f9c8cd0ac90cac60eb478fa02a61ea86 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/b1ece3c05d1bc8678bbe34e666d99de5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:167ce14259ebad7cffcf591706235658756201952396241b22bc26e5cdc2e814 +size 35137 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2b90693e69025867d0dd05d8f98d4ef9b4bf8d2 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ed2f1f4ac06a8bc6ac44f6e3f61e762e6c8489952cf16d65bfea30fe61adb2af +size 4677 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/d6fa99c21af013ef73edd42e2f054807_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/d6fa99c21af013ef73edd42e2f054807_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..04279b6c259c864735004d4cc7fb9db1112c9f7a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/d6fa99c21af013ef73edd42e2f054807_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:160ab327737ff8c18d3df1a880585b7c9cc7830df5a627ac884b4ec3ee5ad764 +size 40199 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/db9a1ff437ab3a063b6fac2ace7fa2cb_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/db9a1ff437ab3a063b6fac2ace7fa2cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6d06762a35ced66fed479cfcaa5d790172ee9f27 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/db9a1ff437ab3a063b6fac2ace7fa2cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:241c0f88eb974088c462041aa8466cd34350b8b156ce20075d2dbad521a9db69 +size 48103 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/e03c31527c056a060dc71706916a66d8_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/e03c31527c056a060dc71706916a66d8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8cd80c9041294fbbf42a804874be0eda026557c6 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/e03c31527c056a060dc71706916a66d8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b3605a2762c66938b6a143d4b5f8fb37f3ec3a09b10d9f660a4660edf4e31fa6 +size 45140 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/e899bbff8ffea1398658ceb611748bf1_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/e899bbff8ffea1398658ceb611748bf1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..be6039f9e603904cbda725f28453765261908c26 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/e899bbff8ffea1398658ceb611748bf1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1e17d095752370a734fa47d5f2f7d5580ceb3320fdb3a8de04c7640270f10f8f +size 67544 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/eed6d5cf1d56a7f90cd9d5f0b482d62f_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/eed6d5cf1d56a7f90cd9d5f0b482d62f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..90661fa9656be91ff2f600fd4337c617cee1f275 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/eed6d5cf1d56a7f90cd9d5f0b482d62f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c2164e3f440e2a2fe3a487e824fa82a8cce3625858b7f791ecd78c5972af96ce +size 65201 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/eed97810b73ce2008906a0918abed322_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/eed97810b73ce2008906a0918abed322_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e9d056186f91071754a1bd66cc5b0f58f9cdcd1d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/eed97810b73ce2008906a0918abed322_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a6feea577002af775f92c1c073ef8e278549447e23549760a568e59d2a4c42d6 +size 4142 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/fa49186bb622c095765fd8ddc772729a_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/fa49186bb622c095765fd8ddc772729a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1af4baa9997cb759fd2b6a6708563bc34a058214 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/fa49186bb622c095765fd8ddc772729a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b7de6899a3e71e7d5cb96e3cf5688867518bde70faaa5a1d8d15817d1aa6097 +size 4042 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/fbd1dd54dcd5cd8cc6544df032aac30a_img.jpg b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/fbd1dd54dcd5cd8cc6544df032aac30a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5b853f6b02e14cf6b26f312460844b133000018f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/fbd1dd54dcd5cd8cc6544df032aac30a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f0466c3995caf7fd4837e1ab4fda39cd2bd182399f10ad967c86936b51fc904e +size 4233 diff --git a/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/raw.md b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..7127f47d660a24b0836543507da98869f9d5a16d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00/raw.md @@ -0,0 +1,2639 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****Study on Security for O-Cloud** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|---------------------------------------------------------|----| +| List of figures ..... | 4 | +| List of tables ..... | 4 | +| Foreword ..... | 5 | +| Modal verbs terminology ..... | 5 | +| Introduction ..... | 5 | +| 1 Scope..... | 6 | +| 2 References..... | 6 | +| 2.1 Informative references..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 10 | +| 3.1 Terms..... | 10 | +| 3.2 Symbols..... | 11 | +| 3.3 Abbreviations ..... | 11 | +| 4 O-Cloud Architecture..... | 14 | +| 4.1 Components..... | 14 | +| 4.1.1 SMO ..... | 14 | +| 4.1.2 O-Cloud management components ..... | 15 | +| 4.1.3 Hardware resources ..... | 15 | +| 4.1.4 Operating System (OS)..... | 15 | +| 4.1.5 Virtualization Layer..... | 15 | +| 4.1.6 NFs Layer ..... | 15 | +| 4.1.7 O-Cloud images repository..... | 15 | +| 4.2 Interfaces ..... | 16 | +| 4.3 Critical services..... | 18 | +| 4.3.1 SERV#01 SMO-O-Cloud O2 services ..... | 18 | +| 4.3.2 SERV#02 O-Cloud images service ..... | 19 | +| 4.3.3 SERV#03 O-Cloud monitoring service ..... | 19 | +| 4.3.4 SERV#04 O-Cloud provisioning service ..... | 20 | +| 4.3.5 SERV#05 O-Cloud software management service ..... | 20 | +| 4.3.6 SERV#06 O-Cloud fault management service ..... | 20 | +| 4.3.7 SERV#07 O-Cloud performance service ..... | 21 | +| 4.3.8 VOID ..... | 21 | +| 4.3.9 SERV#009 O-Cloud Inventory ..... | 21 | +| 5 Cloud deployment scenarios ..... | 22 | +| 5.1 Main actors..... | 22 | +| 5.2 Cloud service models ..... | 22 | +| 5.2.1 Infrastructure as a Service (IaaS)..... | 22 | +| 5.2.2 Platform as a Service (PaaS) ..... | 23 | +| 5.2.3 Software as a Service (SaaS)..... | 23 | +| 5.3 Cloud deployment types..... | 24 | +| 5.3.1 Private cloud..... | 24 | +| 5.3.2 Community Cloud ..... | 25 | +| 5.3.3 Public Cloud ..... | 27 | +| 5.3.4 Hybrid Cloud ..... | 27 | +| 5.4 High-Level risk assessment..... | 29 | +| 6 Roles and responsibilities..... | 34 | +| 7 Security Problem Definition ..... | 35 | +| 7.1 Assets ..... | 35 | +| 7.2 Threats..... | 38 | +| 7.2.1 Threat and impact types..... | 38 | +| 7.2.2 Attack surface..... | 39 | + +| | | | +|-------|------------------------------------------------------------------------------------------|-----| +| 7.2.3 | Vulnerabilities ..... | 40 | +| 7.2.4 | Threat events ..... | 41 | +| 8 | Recommendations and best practices ..... | 69 | +| 8.1 | REC-CM Certificate management ..... | 70 | +| 8.2 | REC-NS Network Segmentation & Filter Network Traffic ..... | 70 | +| 8.3 | REC-IAM Identity, Authentication and Access Management..... | 72 | +| 8.4 | REC-VHPM Vulnerability Handling and Patch Management ..... | 75 | +| 8.5 | REC-SCONF Security Configuration ..... | 75 | +| 8.6 | REC-SDLC Secure Development Lifecycle ..... | 76 | +| 8.7 | REC-SNFLC Security App/VNF/CNF lifecycle ..... | 77 | +| 8.8 | REC-IMGP Image Protection ..... | 78 | +| 8.9 | REC-LOG Logging, Monitoring and Alerting..... | 80 | +| 8.10 | REC-SB Secure Boot ..... | 81 | +| 8.11 | REC-ISO Strong Isolation..... | 81 | +| 8.12 | REC-AUD Security Audit..... | 83 | +| 8.13 | REC-SS Secure Storage ..... | 84 | +| 8.14 | REC-PHY Physical Security Protection ..... | 84 | +| 8.15 | REC-RA Remote Attestation ..... | 86 | +| 8.16 | REC-SDD Secure data deletion ..... | 86 | +| 8.17 | REC-IDM O-Cloud ID secure management ..... | 87 | +| 8.18 | REC-IDM Identity management for O-Cloud elements ..... | 88 | +| 8.19 | REC-ADMC Admission Control ..... | 90 | +| 9 | Risk Assessment ..... | 91 | +| | Annex A (informative): Best practices from some of existing main security guidance ..... | 92 | +| A.1 | CISA/NSA Kubernetes security hardening best practices ..... | 92 | +| A.2 | CIS Docker security best practices..... | 96 | +| A.3 | ONAP VNFs security best practices ..... | 98 | +| | Annex: Change history/Change request (history) ..... | 105 | + +# List of figures + +| | | +|-----------------------------------------------------------------------------|----| +| Figure 4-1 : O-CLOUD architecture ..... | 14 | +| Figure 4-2 : AAL Architecture and interfaces (Source [i.52]) ..... | 18 | +| Figure 4-3 : Parallel reporting & Alarm correlation [i.1] ..... | 20 | +| Figure 5-1 : IaaS cloud service model..... | 23 | +| Figure 5-2 : PaaS cloud service model..... | 23 | +| Figure 5-3 : SaaS cloud service model..... | 24 | +| Figure 5-4 : On-site private cloud ..... | 24 | +| Figure 5-5 : Outsourced private cloud ..... | 25 | +| Figure 5-6 : On-site community cloud..... | 26 | +| Figure 5-7 : Outsourced community cloud ..... | 26 | +| Figure 5-8 : Public cloud..... | 27 | +| Figure 5-9 : Hybrid cloud ..... | 28 | +| Figure 7-1 : Cartography of assets..... | 36 | +| Figure 7-2 : Attack vectors ..... | 44 | +| Figure 7-3 : Vulnerabilities within O-Cloud..... | 44 | +| Figure 7-4 : Illustration of the VM/Container escape attack..... | 53 | +| Figure 7-5 : Illustration of the migration flooding attack ..... | 55 | +| Figure 7-6 : Illustration of the false resource advertising attack..... | 55 | +| Figure 7-7 : Illustration of the migration MITM attack..... | 55 | +| Figure 7-8 : Illustration of the Theft-of-Service/DoS Attack ..... | 57 | +| Figure 7-9 : Illustration of the VM/Container hyperjacking attack ..... | 61 | +| Figure 7-10 : Illustration of a cross VM/Container side channel attack..... | 65 | + +# List of tables + +| | | +|---------------------------------------------------------------------------------|----| +| Table 4-1 : O-Cloud interfaces..... | 19 | +| Table 5-1 : High level security risk assessment of cloud deployment models..... | 34 | +| Table 6-1 : List of Users..... | 36 | +| Table 7-1 : List of Assets..... | 42 | + +# --- Foreword + +This Technical Report (TR) has been produced by the O-RAN Alliance. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- Introduction + +This technical report provides the threat model for the O-Cloud. The report identifies threats, security requirements and recommends potential security controls to protect against identified threats. + +# --- 1 Scope + +The steps of the threat modelling process are as follows: + +1. Identify assets: Identify the valuable assets that the O-Cloud must protect. +2. Identify the threats: Identify the threats that could affect O-Cloud +3. Document the threats: Document each threat using a common threat template that defines a core set of attributes to capture for each threat. +4. Rate the threats: Rate the threats to prioritize and address the most significant threats first. The rating process weighs the probability of the threat against damage that could result should an attack occur. +5. Define potential mitigations to counter the identified threats and reduce their risks. + +The structure of the document is divided into clauses and annexure(s): + +- Clause 4 describes the O-Cloud architecture in terms of components, interfaces, and critical services. +- Clause 5 explores the different deployment types and models. In addition, it provides a high-level risk assessment of those cloud deployment models. +- Clause 6 highlights the main actors of the O-Cloud in terms of roles and responsibilities. +- Clause 7 outlines the security problem definition in terms of assets, attack vectors, vulnerabilities and threats. +- Clause 8 defines recommendations and best practices to mitigate the identified threats. +- Clause 9 figures out the risk assessment of the identified threats in terms of impact and likelihood. +- Annex A provides best practices from some of the main security guidance on cloud, virtualization and containerization. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +[i.1] O-RAN ALLIANCE TS: “O-RAN O2 Interface General Aspects and Principles” + +[i.2] O-RAN ALLIANCE TS: “O-RAN Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN” + +[i.3] CISA/NSA - Kubernetes Hardening Guidance – August 2021 + +[https://media.defense.gov/2021/Aug/03/2002820425/-1/-1/1/CTR\\_KUBERNETESHARDENINGGUIDANCE.PDF](https://media.defense.gov/2021/Aug/03/2002820425/-1/-1/1/CTR_KUBERNETESHARDENINGGUIDANCE.PDF) + +[i.4] MITRE ATT&CK containers matrix + + + +- [i.5] ENISA Threat Landscape for 5G Networks: Threat assessment for the fifth generation of mobile telecommunications networks (5G); November 2019 +- [i.6] ETSI GS NFV-SEC 025 "work in progress." Network Functions Virtualisation (NFV) Release 4; Security; Secure End-to-End VNF and NS management specification +- [i.7] O-RAN ALLIANCE TS: "O-RAN O2dms Interface Specification" +- [i.8] O-RAN ALLIANCE TS: "O-RAN O2ims Interface Specification" +- [i.9] IETF RFC 3647: "Internet X.509 Public Key Infrastructure Certificate Policy and Certification Practices Framework" +- [i.10] ETSI GR NFV-SEC 005 Network Functions Virtualisation (NFV); Trust; Report on Certificate Management +- [i.11] IETF RFC 6749: "The OAuth 2.0 Authorization Framework". +- [i.12] ETSI GS NFV-SEC 022 Network Functions Virtualisation (NFV) Release 2; Security; Access Token Specification for API Access +- [i.13] ETSI GR NFV-SEC 018 Network Functions Virtualisation (NFV); Security; Report on NFV Remote Attestation Architecture +- [i.14] Ludovic Jacquin, Antonio Lioy, Diego R. Lopez, Adrian L. Shaw, and Tao Su "The trust problem in modern network infrastructures" +[https://security.polito.it/doc/public/trust\\_modern\\_network\\_2015.pdf](https://security.polito.it/doc/public/trust_modern_network_2015.pdf) +- [i.15] ETSI GR NFV-SEC 007 Network Functions Virtualisation (NFV); Trust; Report on Attestation Technologies and Practices for Secure Deployments +- [i.16] 3GPP TR 33.848 "Study on security impacts of virtualisation" +- [i.17] OWASP Container Security Verification Standard +[https://owasp.org/www-project-container-security-verification-standard/migrated\\_content](https://owasp.org/www-project-container-security-verification-standard/migrated_content) +- [i.18] CIS Docker Benchmark Securing Docker + +- [i.19] NIST Special Publication 800-190 Application Container Security Guide +- [i.20] OWASP Docker Security Cheat Sheet +[https://cheatsheetseries.owasp.org/cheatsheets/Docker\\_Security\\_Cheat\\_Sheet.html](https://cheatsheetseries.owasp.org/cheatsheets/Docker_Security_Cheat_Sheet.html) +- [i.21] OWASP Kubernetes Security Cheat Sheet +[https://cheatsheetseries.owasp.org/cheatsheets/Kubernetes\\_Security\\_Cheat\\_Sheet.html](https://cheatsheetseries.owasp.org/cheatsheets/Kubernetes_Security_Cheat_Sheet.html) +- [i.22] NIST SP 800-145: The NIST Definition of Cloud Computing +- [i.23] NIST SP 500-322: Evaluation of Cloud Computing Services Based on NIST 800-145 +- [i.24] ONAP VNF Development Requirements – VNF Security + +- [i.25] GSMA NG.126 - Cloud Infrastructure Reference Model + +- [i.26] Aqua Top 20 Docker Security Best Practices: Ultimate Guide + + +[i.27] “Security Impacts of Virtualization on a Network Testbed”, Software Security and Reliability (SERE), 2012 IEEE Sixth International Conference + +[https://www.researchgate.net/publication/261059755\\_Security\\_Impacts\\_of\\_Virtualization\\_on\\_a\\_Network\\_Testbed](https://www.researchgate.net/publication/261059755_Security_Impacts_of_Virtualization_on_a_Network_Testbed) + +[i.28] Beniel Dennyson W, Dr. S. Prabakaran “Detecting Hyperjacking in cloud based virtual environment” + +[https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKewi92Zeznun0AhULHxoKH XO6AkgQFnoECAGQAQ&url=http%3A%2F%2Fserc.org%2Fjournals%2Findex.php%2FIJAST%2Farticle%2Fdownload%2F15440%2F7789%2F&usg=AOvVaw3THwuT\\_S\\_WyKr6miOIJ7GS](https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKewi92Zeznun0AhULHxoKH XO6AkgQFnoECAGQAQ&url=http%3A%2F%2Fserc.org%2Fjournals%2Findex.php%2FIJAST%2Farticle%2Fdownload%2F15440%2F7789%2F&usg=AOvVaw3THwuT_S_WyKr6miOIJ7GS) + +[i.29] Muhammad Kazim “Security Aspects of Virtualization in Cloud Computing” + +[https://www.researchgate.net/publication/273950406\\_Security\\_Aspects\\_of\\_Virtualization\\_in\\_Cloud\\_Computing](https://www.researchgate.net/publication/273950406_Security_Aspects_of_Virtualization_in_Cloud_Computing) + +[i.30] Anita Choudhary “ A critical survey of live virtual machine migration techniques “ + + + +[i.31] Svetlana Kolesnikova, Roman Kulikov, Yuriy Gatchin, Daniil Melnik “Hypervisor Security Analyses Based on Ishikawa Methodology” + +[https://www.researchgate.net/publication/323838205\\_Hypervisor\\_Security\\_Analyses\\_Based\\_on\\_Ishikawa\\_Methodology?enrichId=rgreq-bf37d66002988b1ad9ef24fb09198313-XXX&enrichSource=Y292ZXJQYWdlOzMzMzgzODIwNTtBUzo2MDg0MzY3NTI0ODIzMDVAMTUyMjA3NDZANDM4NQ%3D%3D&el=1\\_x\\_3&\\_esc=publicationCoverPdf](https://www.researchgate.net/publication/323838205_Hypervisor_Security_Analyses_Based_on_Ishikawa_Methodology?enrichId=rgreq-bf37d66002988b1ad9ef24fb09198313-XXX&enrichSource=Y292ZXJQYWdlOzMzMzgzODIwNTtBUzo2MDg0MzY3NTI0ODIzMDVAMTUyMjA3NDZANDM4NQ%3D%3D&el=1_x_3&_esc=publicationCoverPdf) + +[i.32] Mehیار Dabbagh, Ammar Rayes “Internet of Things Security and Privacy” + +[https://www.researchgate.net/publication/309375790\\_Internet\\_of\\_Things\\_Security\\_and\\_Privacy?enrichId=rgreq-69e8c33eb9fc28fccc64fbdad0a91d0-XXX&enrichSource=Y292ZXJQYWdlOzMzMzgzODIwNTtBUzo1NTYxNDY2NDI2OTAwNDhAMTUwOTYwNzEwMDM0OA%3D%3D&el=1\\_x\\_3&\\_esc=publicationCoverPdf](https://www.researchgate.net/publication/309375790_Internet_of_Things_Security_and_Privacy?enrichId=rgreq-69e8c33eb9fc28fccc64fbdad0a91d0-XXX&enrichSource=Y292ZXJQYWdlOzMzMzgzODIwNTtBUzo1NTYxNDY2NDI2OTAwNDhAMTUwOTYwNzEwMDM0OA%3D%3D&el=1_x_3&_esc=publicationCoverPdf) + +[i.33] Changwei Liu, Anoop Singhal, Duminda Wijesekera “A Layered Graphical Model for Cloud Forensic Mission Attack Impact Analysis” + +[https://www.researchgate.net/publication/327314423\\_A\\_Layered\\_Graphical\\_Model\\_for\\_Cloud\\_Forensic\\_Mission\\_Attack\\_Impact\\_Analysis\\_14th\\_IFIP\\_WG\\_119\\_International\\_Conference\\_New\\_Delhi\\_India\\_January\\_3-5\\_2018\\_Revised\\_Selected\\_Papers?enrichId=rgreq-b9ce99f09429d1a36256442e04006d0f-XXX&enrichSource=Y292ZXJQYWdlOzMzMzgzODIwNTtBUzo3NTM0MDM2Mzg1ODMzMDFAMTU1NjYzNjgzMzI4Nw%3D%3D&el=1\\_x\\_3&\\_esc=publicationCoverPdf](https://www.researchgate.net/publication/327314423_A_Layered_Graphical_Model_for_Cloud_Forensic_Mission_Attack_Impact_Analysis_14th_IFIP_WG_119_International_Conference_New_Delhi_India_January_3-5_2018_Revised_Selected_Papers?enrichId=rgreq-b9ce99f09429d1a36256442e04006d0f-XXX&enrichSource=Y292ZXJQYWdlOzMzMzgzODIwNTtBUzo3NTM0MDM2Mzg1ODMzMDFAMTU1NjYzNjgzMzI4Nw%3D%3D&el=1_x_3&_esc=publicationCoverPdf) + +[i.34] Docker Best practices for scanning images + + + +[i.35] Shankar Lal, Tarik Taleb, and Ashutosh Dutta “NFV: Security Threats and Best Practices” + +[http://anastacia-h2020.eu/publications/NFV\\_Security\\_Threats\\_and\\_Best\\_Practices.pdf](http://anastacia-h2020.eu/publications/NFV_Security_Threats_and_Best_Practices.pdf) + +[i.36] NSA/CISA Mitigating Cloud Vulnerabilities + +[https://media.defense.gov/2020/Jan/22/2002237484/-1/-1/0/CSI-MITIGATING-CLOUD-VULNERABILITIES\\_20200121.PDF](https://media.defense.gov/2020/Jan/22/2002237484/-1/-1/0/CSI-MITIGATING-CLOUD-VULNERABILITIES_20200121.PDF) + +[i.37] Fraunhofer AISEC report: Threat analysis of container-as-a-service for network function virtualization + +[https://www.aisec.fraunhofer.de/content/dam/aisec/Dokumente/Publikationen/Studien\\_TechReports/englisch/caas\\_threat\\_analysis\\_wp.pdf](https://www.aisec.fraunhofer.de/content/dam/aisec/Dokumente/Publikationen/Studien_TechReports/englisch/caas_threat_analysis_wp.pdf) + +[i.38] CSA. The treacherous 12: Cloud computing top threats in 2016. Technical report, Cloud Security Alliance, 2016. 12, 14, 15, 16, 17, 27 + +[i.39] ETSI GS NFV-SOL 013 Network Functions Virtualisation (NFV) Release 2; Protocols and Data Models; Specification of common aspects for RESTful NFV MANO APIs + +[i.40] CISA Cloud Security Technical Reference Architecture + +[https://www.cisa.gov/sites/default/files/publications/CISA%20Cloud%20Security%20Technical%20Reference%20Architecture\\_Version%201.pdf](https://www.cisa.gov/sites/default/files/publications/CISA%20Cloud%20Security%20Technical%20Reference%20Architecture_Version%201.pdf) + +[i.41] Guide ANSSI - Hardware security requirements for x86 platforms + +[https://www.ssi.gouv.fr/uploads/2019/11/anssi-guide-hardware\\_security\\_requirements.pdf](https://www.ssi.gouv.fr/uploads/2019/11/anssi-guide-hardware_security_requirements.pdf) + +[i.42] O-RAN ALLIANCE TS: “O-RAN Security Requirements and Controls Specifications” + +[i.43] O-RAN ALLIANCE TS: “O-RAN Operations and Maintenance Architecture” + +[i.44] NSA/CISA Security Guidance for 5G Cloud Infrastructures + + + +[i.45] O-RAN ALLIANCE TS: “O-RAN Security Protocols Specifications” + +[i.46] ETSI GS NFV-SOL 004 Network Functions Virtualisation (NFV) Release 3; Protocols and Data Models; VNF Package and PNFD Archive specification + +[i.47] ETSI GS NFV-SEC 021 Network Functions Virtualisation (NFV) Release 2; Security; VNF Package Security Specification + +[i.48] NIST SP 800-88 ”Guidelines for Media Sanitization” + + + +[i.49] DoD 5220.22-M wiping standard + +[i.50] O-RAN ALLIANCE TR: “O-RAN Security Threat Modeling and Risk Assessment” + +[i.51] O-RAN ALLIANCE TS: “O-RAN Acceleration Abstraction Layer Common API” + +[i.52] O-RAN ALLIANCE TS: “O-RAN Acceleration Abstraction Layer General Aspects and Principles” + +[i.53] Solving the Bottom Turtle - a SPIFFE Way to Establish Trust in Your Infrastructure via Universal Identity + + + +[i.54] SPIRE Concepts: An overview of SPIRE’s architecture and fundamentals + + + +[i.55] Kubernetes Documentation: PKI certificates and requirements + + + +[i.56] Agent plugin: WorkloadAttestor "k8s" + +[https://github.com/spiffe/spire/blob/v1.7.0/doc/plugin\\_agent\\_workloadattestor\\_k8s.md](https://github.com/spiffe/spire/blob/v1.7.0/doc/plugin_agent_workloadattestor_k8s.md) + +[i.57] SPIFFE-ID + + + +[i.58] NIST Special Publication 800-207A + + + +[i.59] CWE-524, "Use of Cache Containing Sensitive Information" + + + +[i.60] CAPEC-204, “Lifting Sensitive Data Embedded in Cache” + + + +[i.61] Infiltrating Corporate Intranet Like NSA + + + +[i.62] O-RAN ALLIANCE TS: “O2 Interface General Aspects and Principles” + +[i.63] O-RAN ALLIANCE TS: “O-RAN Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN” + +[i.64] NIST glossary: + +[i.65] O-RAN ALLIANCE TS: “O2dms Interface Specification: Kubernetes Native API Profile for Containerized NFs” + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 and the following apply: + +**A1:** Interface between non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**A1 Enrichment information:** Information utilized by near-RT RIC that is collected or derived at SMO/non-RT RIC either from non-network data sources or from network functions themselves. + +**A1 policy:** Type of declarative policies expressed using formal statements that enable the non-RT RIC function in the SMO to guide the near-RT RIC function, and hence the RAN, towards better fulfilment of the RAN intent. + +**Deployment ID:** Correlation Identity created by the O-Cloud for the SMO to relate to its inventory and manage. + +**E2:** Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. + +**E2 Node:** A logical node terminating E2 interface. In this version of the specification, O-RAN nodes terminating E2 interface are: + +- for NR access: O-CU-CP, O-CU-UP, O-DU or any combination; +- for E-UTRA access: O-eNB. + +**FCAPS:** Fault, Configuration, Accounting, Performance, Security. + +**Intents:** A declarative policy to steer or guide the behavior of RAN functions, allowing the RAN function to calculate the optimal result to achieve stated objective. + +**Near-RT RIC:** O-RAN near-real-time RAN Intelligent Controller: a logical function that enables real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. + +**NF Deployment:** An O-Cloud NF Deployment is a deployment of a cloud native Network Function (all or partial), resources shared within a NF Function, or resources shared across network functions. The NF Deployment configures and assembles user-plane resources required for the cloud native construct used to establish the NF Deployment and manage its life cycle from creation to deletion (Refer to clause 1.3.1 O-RAN WG6.GA&P [i.1]). + +**NF Deployment Descriptor:** A completed data model which provides an O-Cloud the necessary information to create a deployment. + +**Non-RT RIC:** O-RAN non-real-time RAN Intelligent Controller: a logical function that enables non-real-time control and optimization of RAN elements and resources, AI/ML workflow including model training and updates, and policy-based guidance of applications/features in Near-RT RIC. + +**O-Cloud:** O-RAN cloud is a distributed cloud composed of Cloud Resource Pools where each pool is a collection of Cloud Resources within a Cloud Site with a specific location. [i.62] + +**O-Cloud instance ID:** The O-Cloud instance ID is a unique identifier assigned to components within the O-Cloud platform, including VMs, pods, containers, nodes, and compute pools (i.e., a cluster in Kubernetes). This ensures uniqueness across the entire O-Cloud environment, irrespective of the component type. For instance, a VM, a pod, a container, a node, and a cluster will each have a distinct O-Cloud instance ID within the platform, ensuring that there is no ambiguity in identification. + +**O-Cloud Node:** An O-Cloud Node is exposed over O2ims as an Abstracted Resource. It is a collection of CPUs, Mem, Storage, NICs, Accelerators, BIOSes, BMCs, etc., and can be thought of as a server (Refer to clause 3.1 in O-RAN WG6.GA&P [i.1]). + +**O-Cloud Resource:** Refer to clause 3.4.3.2.1 in O-RAN WG6.GA&P [i.1] + +**O-Cloud Software:** The O-Cloud software refers to a collection of Host OS, Hypervisor/Container engine, AAL (Acceleration Abstraction Layer), IMS, DMS, HAM (Hardware Accelerator Manager), and supporting software in O-Cloud to run VNFs/CNFs. [i.63] + +**O-CU:** O-RAN Central Unit: a logical node hosting O-CU-CP and O-CU-UP + +**O-CU-CP:** O-RAN Central Unit – Control Plane: a logical node hosting the RRC and the control plane part of the PDCP protocol. + +**O-CU-UP:** O-RAN Central Unit – User Plane: a logical node hosting the user plane part of the PDCP protocol and the SDAP protocol. + +**O-DU:** O-RAN Distributed Unit: a logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. + +**O-RU:** O-RAN Radio Unit: a logical node hosting Low-PHY layer and RF processing based on a lower layer functional split. This is similar to 3GPP's "TRP" or "RRH" but more specific in including the Low-PHY layer (FFT/iFFT, PRACH extraction). + +**O1:** Interface between management entities (NMS/EMS/MANO) and O-RAN managed elements, for operation and management, by which FCAPS management, Software management, File management shall be achieved. + +**RAN:** Generally referred as Radio Access Network. In terms of this document, any component below Near-RT RIC per O-RAN architecture, including O-CU/O-DU/O-RU. + +**Sensitive:** A descriptor of information whose loss, misuse, or unauthorized access or modification could adversely affect security [i.64]. + +**Service Provider:** A network provider who is planning to deploy applications into their network. + +**Solution Provider:** An application developer who delivers applications to Service Providers. + +**Workload -** Refer to clause 3.4.3.1 in O-RAN WG6.GA&P [i.1] + +**NOTE:** For the purposes of the present document, the AAL terms and definitions given in [i.52] apply. + +## 3.2 Symbols + +void + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 and the following apply: + +| | | +|-------------|-------------------------------------------------------------| +| AAL | Acceleration Abstraction Layer | +| AALI | Acceleration Abstraction Layer Interface | +| AALI-C | Acceleration Abstraction Layer Interface-Common | +| AALI-C-App | Acceleration Abstraction Layer Interface-Common-Application | +| AALI-C-Mgmt | Acceleration Abstraction Layer Interface-Common-Management | +| AALI-P | Acceleration Abstraction Layer Interface-Profile | +| AI/ML | Artificial Intelligence/Machine Learning | + +| | | +|---------|-------------------------------------------------------------------------------------------------------------| +| CNF | Cloud-native Network Function (NOTE: same as Containerized Network Function or Cloudified Network Function) | +| DMS | O-Cloud Deployment Management Services | +| eNB | eNodeB (applies to LTE) | +| FOCOM | Federated O-Cloud Orchestration & Management | +| FTP | File Transfer Protocol | +| FTPS | File Transfer Protocol Secure | +| gNB | gNodeB (applies to NR) | +| IMS | O-Cloud Infrastructure Management Services | +| IPSEC | Internet Protocol Security | +| KPI | Key Performance Indicator | +| KQI | Key Quality Indicator | +| LBT | Listen Before Talk | +| LCM | Life Cycle Management | +| LLS | Lower Layer Split | +| MIMO | Multiple Input, Multiple Output | +| MNO | Mobile Network Operator | +| NETCONF | Network Configuration Protocol | +| NF | Network Function | +| NFO | Network Function Orchestration | +| NFV | Network Function Virtualisation | +| NFVI | Network Function Virtualization Infrastructure | +| O-CU | O-RAN Central Unit as defined by O-RAN ALLIANCE | +| O-CU-CP | O-CU Control Plane | +| O-CU-UP | O-CU User Plane | +| O-DU | O-RAN Distributed Unit (uses Lower-level Split) | +| O-RU | O-RAN Radio Unit | +| PDCP | Packet Data Convergence Protocol | +| PNF | Physical Network Function | +| PRB | Physical Resource Block | +| PTP | Precision Timing Protocol | +| QoE | Quality of Experience | +| RAN | Radio Access Network | +| RASP | Runtime Application Self-Protection | +| RBAC | Role-based Access Control | +| RIC | O-RAN RAN Intelligent Controller | +| SDN | Software Defined Network | +| SIEM | Security information and event management | +| SINR | Signal-to-Interference-plus-Noise Ratio | +| SMO | Service Management and Orchestration | +| SSH | Secure Shell | + +| | | +|-----|------------------------------| +| TLS | Transport Layer Security | +| UAV | Unmanned Aerial Vehicle | +| V2X | Vehicle to Everything | +| VM | Virtual machine | +| VNF | Virtualised Network Function | + +# 4 O-Cloud Architecture + +The O-Cloud architecture is depicted in the following figure: + +![Figure 4-1: O-CLOUD architecture diagram. The diagram shows the SMO (Service Management and Orchestration) layer at the top, containing Non RT RIC/rApps, NFO (Network Function Orchestrator), and FOCOM (Federated O-Cloud Orchestration and Management). The SMO is connected to an Images repository. The O-Cloud layer is divided into VNF/CNF (Virtual Network Functions/Cloud Network Functions) and a Virtualization Layer (VL). The VNF/CNF layer contains O-DU, O-CU, and Near RT RIC/xApps. The Virtualization Layer (VL) contains Containers, VMs, and a Container Engine. The VL is connected to the Host OS and Hypervisor (Type I). The Host OS and Hypervisor (Type I) are connected to the Hardware resources (Compute, Storage, Network, Hardware Accelerator manager). The SMO is connected to the O-Cloud via O1, A1, O2dms, and O2ims interfaces. The O-Cloud is connected to the Images repository via O1 and A1 interfaces. The O-Cloud is connected to the Hardware resources via O2dms and O2ims interfaces.](37289ad05957180b7fdd41db6386cf76_img.jpg) + +Figure 4-1: O-CLOUD architecture diagram. The diagram shows the SMO (Service Management and Orchestration) layer at the top, containing Non RT RIC/rApps, NFO (Network Function Orchestrator), and FOCOM (Federated O-Cloud Orchestration and Management). The SMO is connected to an Images repository. The O-Cloud layer is divided into VNF/CNF (Virtual Network Functions/Cloud Network Functions) and a Virtualization Layer (VL). The VNF/CNF layer contains O-DU, O-CU, and Near RT RIC/xApps. The Virtualization Layer (VL) contains Containers, VMs, and a Container Engine. The VL is connected to the Host OS and Hypervisor (Type I). The Host OS and Hypervisor (Type I) are connected to the Hardware resources (Compute, Storage, Network, Hardware Accelerator manager). The SMO is connected to the O-Cloud via O1, A1, O2dms, and O2ims interfaces. The O-Cloud is connected to the Images repository via O1 and A1 interfaces. The O-Cloud is connected to the Hardware resources via O2dms and O2ims interfaces. + +Figure 4-1 : O-CLOUD architecture + +## 4.1 Components + +The following clauses describe the functional blocks identified in Figure 4-1 [i.1], [i.2]: + +### 4.1.1 SMO + +The SMO components managing and orchestrating the O-Cloud software are: + +- **Federated O-Cloud Orchestration and Management (FOCOM):** The FOCOM is responsible for accounting and asset management of the resources in the cloud. The FOCOM is the primary consumer of services provided by the IMS. The FOCOM has information about the O-Cloud resources management. Specifically, the FOCOM needs to know whether the services are within the operator domain or external. +- **Network Function Orchestrator (NFO):** The NFO is responsible for orchestrating the assembly of the network functions as a composition of NF Deployments in the O-Cloud. It may also utilize OAM Functions in order to access the O1 interface to the NF once it is deployed. Its use of the O1 is not germane to the O2 and is only mentioned here for completeness. The NFO is the primary consumer of the DMS. + +### 4.1.2 O-Cloud management components + +The O-Cloud components providing management services for consumption of SMO are: + +- **Infrastructure Management Services (IMS):** The IMS is responsible for management of the O-Cloud resources and the software which is used to manage those resources. The IMS generally provides services for consumption by the FOCOM. +- **Deployment Management Services (DMS):** The DMS is responsible for management of NF Deployments into the O-Cloud. It provides the ability to instantiate, monitor, and terminate NF Deployments. The DMS generally provides services for consumption by the NFO. + +### 4.1.3 Hardware resources + +- **A Computer System** is defined to be a physical or composed system capable of performing computations that is Underlay-Network connected. A Computer System can run any major Operating System with or without Virtualization and/or Container support functionality. + +NOTE: A computer system in the context of a cloudified network and usage in cluster requires a network connectivity. For example, a server in a data center connected to an underlay network. + +- **An underlay network** is a physically connected network enabling Computer Systems to communicate with each other and with the gateway(s) connected to networks outside of the data center. +- **Hardware accelerator manager:** It is an acceleration management function, that provides management capabilities for the HW Accelerator(s) in the O-Cloud Node. Management capabilities include but not limited to lifecycle management, configuration, updates/upgrades and failure handling. Hardware Accelerators include ASIC, FPGA, DSP and GPU. + +### 4.1.4 Operating System (OS) + +An Operating system is a software platform that manages and abstracts the Computer System hardware and software resources as well as provides common services for NFs such as scheduling and network connectivity. + +### 4.1.5 Virtualization Layer + +- **Hypervisor (VMs):** An hypervisor is an OS that includes the ability to offer multiple Virtual Machines, each acting as a well-separated Computer System. +- **Container Engine:** A Container Engine is an OS that include the ability to offer multiple separated name spaces, quotas, and management for Containers. + +### 4.1.6 NFs Layer + +The following are three deployment scenarios of a NF: + +1. **Bare Metal Container Cluster** – A Bare Metal Container Cluster is a set of network-connected computer systems with their individual operating system instances that supports containers in a cluster configuration. +2. **VM-based Container Cluster** – A VM-based Container Cluster is a set of network-connected Virtual Machines with their individual guest operating system instance that supports containers in a clustered configuration. +3. **VM Cluster** – A VM Cluster is a set of network-connected Computer Systems with their individual operating instance that supports virtual machines in a cluster configuration. + +### 4.1.7 O-Cloud images repository + +The repository containing the Software Images of O-RAN Network Functions. + +## 4.2 Interfaces + +O-Cloud interfaces are illustrated in the following table: + +| Interfaces | Interface between | Exposure | Description | Security protection | +|------------|----------------------------------------------------------|----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------| +| O2dms | SMO and O-Cloud Deployment Management Services (DMS) | External |

It is responsible for the deployment management services of the NF Deployment. It offers the following services APIs [i.7]:

  • • O2dms_DeploymentInventory Services
  • • O2dms_DeploymentProvisioning Services
  • • O2dms_DeploymentFault Services
  • • O2dms_DeploymentPerformance Services
  • • O2dms_DeploymentLifecycle Services
| TLS 1.2/1.3 | +| O2ims | SMO and O-Cloud Infrastructure Management Services (IMS) | External |

It is responsible for infrastructure management services for O-Cloud Nodes. It offers the following services APIs [i.8]:

  • • O2ims_InfrastructureInventory Services: Service for querying the O-Cloud resources and management services.
  • • O2ims_InfrastructureMonitoring Services: Service for configuring telemetry reporting of O-Cloud infrastructure resources.
  • • O2ims_InfrastructureProvisioning Services: Service for configuring the O-Cloud infrastructure resources and management services.
  • • O2ims_InfrastructureSoftwareManagement Services: Services for software inventory and updating the software used for O-Cloud infrastructure resources and management services.
  • • O2ims_InfrastructureLifecycleManagement Services: Services related to O-Cloud infrastructure lifecycle management and events.
| TLS 1.2/1.3 | +| O1 | SMO and the RAN managed functions | External |

SMO performs relevant configuration updates in RAN over O1 interface for each network function.

SMO on operator request can perform recover (reset) of an application (in case of failures) within a NF through the O1 interface.

SMO is notified of configuration events, fault events and performance measurements from an O-RAN NF instantiated on an O-Cloud, using the O1 interface.

SMO retrieves configuration data from NFs through O1.

| TLS 1.2/1.3 | + +| | | | | | +|--------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| +| O-Cloud APIs | O-Cloud infrastructure and VNFs/CNFs | Internal | The interface is used to specify interactions between the VNFs/CNFs and O-Cloud. The interfaces can be used by the VNFs/CNFs to register/deregister for receiving events from the O-Cloud. | HTTPS (HTTP over TLS) | +| Management (Tenant level APIs) | External interfaces are use case specific interfaces that are not standardized in O-RAN. Security of these interfaces is outside the scope of this work item and recommended to be outside the scope of the O-RAN Alliance. | External | APIs for the management (creation, deletion, and operation) of the Tenant, software flavours, Operating System and workload images, Identity and Authorization, virtual resources, security, and the workload application. | HTTPS | +| Enabler Service Interfaces | External interfaces are use case specific interfaces that are not standardized in O-RAN. Security of these interfaces is outside the scope of this work item and recommended to be outside the scope of the O-RAN Alliance. | External | An operational O-Cloud needs a set of standard services to function. Services such as NTP for time synchronization, DHCP for IP address allocation, DNS for obtaining IP addresses for domain names, and LBaaS to distribute incoming requests amongst a pool of designated resources. | HTTPS | + +**Table 4-1 : O-Cloud interfaces** + +AAL interfaces are as follows [i.51]: + +- AALI-C-Mgmt: between the O-Cloud IMS/DMS and the Hardware Accelerator Manager. It is consistent with O2 interface. +- AALI-C-App: common APIs between O-RAN NFs and the hardware accelerator device for initial discovery, AAL initialization, runtime operations, real time telemetry and status, etc. +- AALI-P: Profile specific API – fine grain control over selection and off-loading, etc. The AALI configuration and management APIs are the APIs that an application (O-DU) executes to configure and manage the AAL-LPU(s) that have been allocated to the application by the O-Cloud. +- Vendor specific interface between the hardware accelerator manager and hardware accelerator device. + + + +- Request the O-Cloud to reset O-Cloud Node(s) +- Issue a subscription to the O-Cloud to receive alarm event notifications +- Query the O-Cloud for alarms on O-Cloud resources with query criteria which define the alarm characteristics that the SMO is interested in +- Query the O-Cloud for state and status information +- Perform an Alarm Subscription query towards the IMS +- Perform a NF deployment (that releases an NF instance) reset through the O2dms interface +- Perform an O-Cloud Node (recovery of the resources within the O-Cloud) reset through the O2ims interface + +Using the O2 interface, the O-Cloud can perform the following operations: + +- Send asynchronous events to the SMO when available capabilities or capacities are changed, including when new hardware is added +- Asynchronously notify the SMO when a software upgrade completes +- Asynchronously notify the endpoint specified by the SMO (alarm subscriber) of alarm notifications related to O-Cloud resources +- Return alarms in response to the SMO alarm query that match the alarm query criteria + +### 4.3.2 SERV#02 O-Cloud images service + +It provides Add/Delete/Update/Query functions of O-RAN Cloudified Network Functions images with their related information (e.g. SoftwareImageId, Vendor, and Version) from O-Cloud repository. + +### 4.3.3 SERV#03 O-Cloud monitoring service + +When the O-Cloud Infrastructure or the O-RAN cloudified NFs fails, it needs to be fixed immediately, and preferably automatically, to prevent end users from experiencing service disruptions. To avoid this service disruption Network Operations must consider the telemetry information of O-Cloud deployments in the network. The telemetry information serves as a vital resource for analysing the O-Cloud's state and health, and for delivering on service monitoring goals. The O-Cloud Monitoring Service uses telemetry data to provide monitoring of O-Cloud infrastructures. O-Cloud telemetry shall minimally consist of Fault, Performance, and Configuration Data. There are different types of telemetry: + +- **Managed Element Telemetry** to monitor the NFs behavior through O1. +- **Deployment Telemetry** to monitor the number of deployment instances an O-Cloud has at that moment and how many were expected, how the on-progress deployment is going, and health checks. Additional Deployment Telemetry metrics like CPU, network, and memory usage can also be collected. This will be performed through the O2dms interface. +- **Infrastructure Telemetry** to monitor the health of the O-Cloud Infrastructure components. Network Operations are interested in discovering if all the components in the O-Cloud Infrastructure are working properly and at what capacity, how many deployments are running on each node, and the resource utilization of the O-Cloud Infrastructure. This will be performed through the O2ims interface. + +The SMO shall be able to collect and correlate telemetries to aggregate problems to a root cause. + +The O-Cloud shall be able to report telemetries and make all Configuration Data and any external changes to it available to the SMO. + +### 4.3.4 SERV#04 O-Cloud provisioning service + +O-Cloud Provisioning is the allocation of O-Cloud's resources and services to an O-RAN Cloudified Network Function. This is one of the key functionalities of the O-Cloud, relating to how an O-RAN Cloudified Network Function procures O-Cloud services and resources. O-Cloud Provisioning shall provide: + +- Create/Read/Update/Delete rules for Affinity, Anti-Affinity, and Quorum Diversity +- Query of O-Cloud Capacity & Availability + +### 4.3.5 SERV#05 O-Cloud software management service + +Software management will manage the O-Cloud software. The software management should be a priority as without proper management unnecessary risks may be taken. The software management ensures security, cost management and software support. There are many benefits to software management, of which the main benefits are: + +- Prevents unauthorized software from being installed +- Maintains a catalog of authorized software and its versions +- Provides visibility into what software and version is being used +- Provides a better view of which software products and versions are vendor supported + +In O-RAN from an O-Cloud perspective there are two types of software which needs to be managed on the O2 Interface: + +- The O-Cloud Infrastructure Software +- The O-RAN Cloudified Network Function Software is the software implementation of O-RAN NFs which can run over the O-Cloud + +### 4.3.6 SERV#06 O-Cloud fault management service + +It is related to IMS & DMS fault management. There are three types of fault notifications that originate from O-Cloud and collected by SMO through O1, O2dms and O2ims. + +- Fault notifications originate from the O-cloud infrastructure when a condition occurs within IMS on an O-Cloud resource. An event is issued towards the SMO for analysis. The SMO can issue a specific fault query towards to IMS related to the O-Cloud resources and resource pool through O2ims. +- DMS resource faults are associated with a workload. The SMO can issue a specific query related to xApp/NF deployments (e.g. workloads) from the DMS through O2dms. +- NFs faults are reported through O1 (application level). + +![Figure 4-3: Parallel reporting & Alarm correlation [i.1]. The diagram shows a layered architecture. At the top is the SMO (Service Management Orchestrator) in the Management layer, containing FOCOM and NFO. Below it is the Applications layer with an Applications box, and the DMS Workloads layer with a Workloads box. At the bottom is the IMS Resources layer, represented by a server rack. Arrows indicate data flow: O2ims from IMS Resources to FOCOM, O2dms from Workloads to NFO, and O1 from Applications to NFO.](1e14c438d72178947accdb2929913590_img.jpg) + +Figure 4-3: Parallel reporting & Alarm correlation [i.1]. The diagram shows a layered architecture. At the top is the SMO (Service Management Orchestrator) in the Management layer, containing FOCOM and NFO. Below it is the Applications layer with an Applications box, and the DMS Workloads layer with a Workloads box. At the bottom is the IMS Resources layer, represented by a server rack. Arrows indicate data flow: O2ims from IMS Resources to FOCOM, O2dms from Workloads to NFO, and O1 from Applications to NFO. + +**Figure 4-3 : Parallel reporting & Alarm correlation [i.1]** + +It is possible that multiple resources can associate with a workload, whereby one fault might trigger a fault notification on IMS, DMS and O1. + +For example, it is conceivable that a O-DU application might report a fault on O1, and a related physical server allocated to a workload of a O-DU would raise a DMS fault which might also have an infrastructure fault raised on IMS. + +For example, the SMO may receive a fault with a root cause of a network issue among the O-Cloud resources which manifests itself in a deployment and application fault as well. Thus, the SMO might receive three notifications over O2ims, O2dms and O1. It might correlate these faults to a common root cause. + +NOTE: Faults issued by the O-Cloud could be stored at the O-Cloud resource for a configured amount of time. + +### 4.3.7 SERV#07 O-Cloud performance service + +The purpose of performance service is to report operational information related to O-cloud resources. Typically, performance information allows an operator or administrator of the O-cloud a sense of how well the system is operating. It is distinct from faults in that it is not about failures in the system but about how well the overall system is performing. Though, faults or alarms may negatively impact performance of the O-Cloud which might be observable in performance measurements. + +Performance measurements are typically captured periodically through time. They are collected and stored at regular intervals by the system in order to gauge the performance of a system over a period of time. This allows for analytical operations to be performed on the collected data and statistics to be built over time. This can tell an operator or system analyst whether they have sufficient capacity in a network based on the demands of the network. This can be vital for making business operational decisions such as scaling a network. + +### 4.3.8 VOID + +### 4.3.9 SERV#009 O-Cloud Inventory + +O-Clouds contain physical, software and logical resources. The O-Cloud is the source of information for these assets but is required to provide a mechanism for asset management to account for them. The inventory services provide the read-only interface to its inventory such that accounting can be achieved (see O-RAN O2ims Interface Specification [i.8]). One of the responsibilities of the SMO is for “financial” accounting of the physical and logical inventory. The SMO inquires about the mapping of resources to their use. The O-Cloud is responsible for the assignment of resources to their use. Typically, the O-Cloud inventory is the result of the SMO provisioning requests and assignments of O- + +Cloud Resources with additions of O-Cloud internal status of the existing internal resources, e.g., if some of the resources are down due to faults or maintenance operations (see O-RAN WG6.GA&P [i.1]). + +**Infrastructure Inventory** - Infrastructure inventory plays a pivotal role in the management and allocation of O-Cloud resources. It involves the use of an immutable O-Cloud Resource Identifier to track resources efficiently. This identifier aids in correlating inventory data, which includes provisioning status and operational insights. + +**Logical Inventory** - Logical inventory involves managing the Deployment Management Services (DMS) that support various virtual cluster technologies, such as Kubernetes and OpenStack. Each DMS endpoint acts as an interface for deployments, cataloged by the SMO as a Logical Cloud. This inventory segment assists the SMO in selecting appropriate O-Cloud environments for deployments. + +**Deployment Inventory** - Focusing on the deployment aspect, the inventory includes Deployment Descriptors that detail the resources allocated for services, such as VMs, Pods, Containers, and Networks. Each descriptor corresponds with specific O-Cloud capabilities and returns a unique Deployment ID, crucial for tracking and managing deployment specifics over the O2dms interface. + +# --- 5 Cloud deployment scenarios + +## 5.1 Main actors + +1. Operator +2. CSP (Cloud Service Provider) +3. Vendors +4. Third parties (e.g. service providers, verticals) + +## 5.2 Cloud service models + +Different levels of abstraction constitute the platform of the cloud architecture. These abstractions are grouped into the different service levels, depending on what resources are offered as a service for a given abstraction level. According to NIST SP 800-145 the three standard cloud service models are Platform as a Service (PaaS), Software as a Service (SaaS), and Infrastructure as a Service (IaaS). + +### 5.2.1 Infrastructure as a Service (IaaS) + +The capability provided to the Operator is to provision processing, storage, networks, and other fundamental computing resources where the Operators or Vendors are able to deploy and run arbitrary software, which can include Host OS (Operator or Vendor), virtualization platforms (Operator or Vendor) and VNFs/CNFs (Operator). Operators and Vendors do not manage or control the underlying cloud infrastructure but have control over Host OS (Operator or Vendor), virtualization platforms (Operator or Vendor) and VNFs/CNFs (Operator). + +![IaaS cloud service model diagram](7f5f93e2f0ad459989e28fdfca1aaf1e_img.jpg) + +The diagram illustrates the IaaS cloud service model. At the top, four grey boxes labeled 'VNF/CNF' are shown. Below them is a grey box labeled 'NFVO'. In the center, a large blue box is labeled 'Hypervisor or Container Engine'. Below that is a blue box labeled 'Host OS'. At the bottom, a large blue box is labeled 'Hardware resources (Compute, Storage, Network)'. To the right of this box is a blue box labeled 'VIM'. Below the main stack, three boxes are shown: 'Cloud Provider' (blue), 'Operator' (grey), and 'Vendor' (grey). + +IaaS cloud service model diagram + +Figure 5-1 : IaaS cloud service model + +### 5.2.2 Platform as a Service (PaaS) + +The capability provided to the Operator is to deploy onto the cloud infrastructure VNFs/CNFs created using programming languages, libraries, services, and tools supported by the cloud provider. The Operator does not manage or control the underlying cloud infrastructure including network, servers, operating systems, or storage, but has control over the deployed VNFs/CNFs and possibly configuration settings for the application-hosting environment. PaaS provides this platform from the cloud, hence allowing operators to develop and run VNFs/CNFs without the overhead cost (CAPEX) of building and maintaining separate platforms. + +![PaaS cloud service model diagram](d6fa99c21af013ef73edd42e2f054807_img.jpg) + +The diagram illustrates the PaaS cloud service model. At the top, four grey boxes labeled 'VNF/CNF' are shown. Below them is a grey box labeled 'NFVO'. In the center, a large blue box is labeled 'Hypervisor or Container Engine'. Below that is a blue box labeled 'Host OS'. At the bottom, a large blue box is labeled 'Hardware resources (Compute, Storage, Network)'. To the right of this box is a blue box labeled 'VIM'. Below the main stack, two boxes are shown: 'Cloud Provider' (blue) and 'Operator' (grey). + +PaaS cloud service model diagram + +Figure 5-2 : PaaS cloud service model + +### 5.2.3 Software as a Service (SaaS) + +SaaS as defined by NIST is the capability provided to the Cloud Consumer to use the Cloud Provider's applications running on a cloud infrastructure. Applications are accessible through web browser or program interface. The operator does not manage or control the underlying cloud infrastructure including network, servers, operating systems, storage, or even Applications. + +![Diagram of the SaaS - NIST cloud service model. It shows a stack of layers: Applications (three instances), Hypervisor or Container Engine, Host OS, and Hardware resources (Compute, Storage, Network). To the right of this stack are three management layers: NFVO, VNFM/CNFM, and VIM. Below the entire stack is a box labeled Cloud Provider.](5f3ad2f36edbd22288f07995dbd0944a_img.jpg) + +**SaaS - NIST** + +Diagram of the SaaS - NIST cloud service model. It shows a stack of layers: Applications (three instances), Hypervisor or Container Engine, Host OS, and Hardware resources (Compute, Storage, Network). To the right of this stack are three management layers: NFVO, VNFM/CNFM, and VIM. Below the entire stack is a box labeled Cloud Provider. + +**Figure 5-3 : SaaS cloud service model** + +This service model introduces risk for the Operator, acting as the Cloud Consumer, due to shared resources, reduced control, lack of transparency for data security, secure access configuration, limited visibility to logging at lower layers, malicious insiders, regulatory drift, and lack of due diligence. It is not expected that 5G operators will deploy with the SaaS service model. + +The Cloud Provider may offer 5G private networks directly to its customers in a SaaS service model. In this service model the Cloud Provider's customer is the Cloud Consumer, which has responsibility for securing its data and access to the applications. + +## 5.3 Cloud deployment types + +In NIST SP 800-145, cloud deployment models describe how the cloud is operated and who has access to the cloud service resources. The four deployment models are defined in NIST SP 800-145 as follows: + +### 5.3.1 Private cloud + +A private cloud gives a single Operator the exclusive access to and usage of the cloud service and related infrastructure and computational resources. It may be managed either by the Operator or by a third party Cloud Provider and may be hosted on the Operator's premises (i.e., on-site private clouds) or outsourced to a hosting company (i.e., outsourced private clouds). The following figures present an on-site private cloud and an outsourced private cloud, respectively. + +![Diagram of an On-site Private Cloud. An Operator (represented by a gear icon) is shown above a Private Cloud stack. The stack includes VNF/CNF (four instances), Hypervisor or Container Engine, Host OS, and Hardware resources (Compute, Storage, Network). To the right of the stack are three management layers: NFVO, VNFM/CNFM, and VIM. The entire stack is enclosed in a rounded rectangle labeled On-Site Private Cloud.](e03c31527c056a060dc71706916a66d8_img.jpg) + +Diagram of an On-site Private Cloud. An Operator (represented by a gear icon) is shown above a Private Cloud stack. The stack includes VNF/CNF (four instances), Hypervisor or Container Engine, Host OS, and Hardware resources (Compute, Storage, Network). To the right of the stack are three management layers: NFVO, VNFM/CNFM, and VIM. The entire stack is enclosed in a rounded rectangle labeled On-Site Private Cloud. + +**Figure 5-4 : On-site private cloud** + +![Figure 5-5: Outsourced private cloud architecture diagram. The diagram shows an 'Outsourced Private Cloud' managed by a 'Cloud Service Provider' (represented by a gear icon). The cloud stack includes 'Private Cloud' (with four 'VNF/CNF' blocks), 'Hypervisor or Container Engine', 'Host OS', and 'Hardware resources (Compute, Storage, Network)'. To the right, an 'Operator' (represented by a gear icon) interacts with the cloud stack. The stack also includes 'NFVO', 'VNFM/CNFM', and 'VIM' components.](db9a1ff437ab3a063b6fac2ace7fa2cb_img.jpg) + +Figure 5-5: Outsourced private cloud architecture diagram. The diagram shows an 'Outsourced Private Cloud' managed by a 'Cloud Service Provider' (represented by a gear icon). The cloud stack includes 'Private Cloud' (with four 'VNF/CNF' blocks), 'Hypervisor or Container Engine', 'Host OS', and 'Hardware resources (Compute, Storage, Network)'. To the right, an 'Operator' (represented by a gear icon) interacts with the cloud stack. The stack also includes 'NFVO', 'VNFM/CNFM', and 'VIM' components. + +Figure 5-5 : Outsourced private cloud + +#### On-site private cloud + +| Cloud type | Cloud model | Hardware | Host OS | Container Engine or Hypervisor | VNFs/CNFs | +|-----------------|-----------------|---------------|---------------|--------------------------------|-----------| +| On-site private | SaaS On-Premise | Operator | Operator | Operator | Operator | +| On-site private | IaaS | Operator, CSP | CSP, Operator | Operator, Vendors | Operator | +| On-site private | PaaS | Operator, CSP | CSP, Operator | CSP, Operator | Operator | + +#### Outsourced private cloud + +| Cloud type | Cloud model | Hardware | Host OS | Container Engine or Hypervisor | VNFs/CNFs | +|--------------------|-----------------|---------------|---------------|--------------------------------|-----------| +| Outsourced private | SaaS On-Premise | NA | NA | NA | NA | +| Outsourced private | IaaS | Operator, CSP | CSP, Operator | Operator, Vendors | Operator | +| Outsourced private | PaaS | Operator, CSP | CSP, Operator | CSP, Operator | Operator | + +### 5.3.2 Community Cloud + +A community cloud serves a group of Operators that have shared concerns such as mission objectives, security, privacy and compliance policy, rather than serving a single Operator (e.g., a private cloud). Similar to private clouds, a community cloud may be managed by the Operators or by a third party Cloud Provider and may be implemented on the Operator's premise (i.e., on-site community cloud) or outsourced to a hosting company (i.e., outsourced community cloud). Figure 5-6 depicts an on-site community cloud comprised of a number of participant Operators. An Operator can access the local cloud resources, and also the resources of other Operators through the connections between the associated Operators. Figure 5-7 shows an outsourced community cloud, where the server side is outsourced to a hosting company. In this case, an outsourced community cloud builds its infrastructure off premise, and serves a set of Operators that request and consume cloud services. + +![Figure 5-6: On-site community cloud architecture diagram. The diagram shows three operators (Operator A, Operator B, Operator C) interacting with a stack of local clouds. The stack consists of Local Cloud (Operator C) on top, followed by Local Cloud (Operator B), and Local Cloud (Operator A) at the bottom. Each local cloud contains VNF/CNF blocks. Below the local clouds is a Hypervisor or Container Engine, followed by a Host OS, and finally Hardware resources (Compute, Storage, Network). To the right of the stack are three orange blocks: NFVO, VNFM/CNFM, and VIM, which are shared across the operators.](eed6d5cf1d56a7f90cd9d5f0b482d62f_img.jpg) + +Figure 5-6: On-site community cloud architecture diagram. The diagram shows three operators (Operator A, Operator B, Operator C) interacting with a stack of local clouds. The stack consists of Local Cloud (Operator C) on top, followed by Local Cloud (Operator B), and Local Cloud (Operator A) at the bottom. Each local cloud contains VNF/CNF blocks. Below the local clouds is a Hypervisor or Container Engine, followed by a Host OS, and finally Hardware resources (Compute, Storage, Network). To the right of the stack are three orange blocks: NFVO, VNFM/CNFM, and VIM, which are shared across the operators. + +Figure 5-6 : On-site community cloud + +![Figure 5-7: Outsourced community cloud architecture diagram. The diagram shows a Cloud Provider interacting with a Private Cloud. The Private Cloud stack includes VNF/CNF blocks, a Hypervisor or Container Engine, a Host OS, and Hardware resources (Compute, Storage, Network). To the right of the stack are three orange blocks: NFVO, VNFM/CNFM, and VIM. Three operators (Operator A, Operator B, Operator C) are shown on the right, with arrows pointing to the VNFM/CNFM block, indicating they interact with the cloud management functions.](463cd4df73fa4fe65bb1efc7c143e8b7_img.jpg) + +Figure 5-7: Outsourced community cloud architecture diagram. The diagram shows a Cloud Provider interacting with a Private Cloud. The Private Cloud stack includes VNF/CNF blocks, a Hypervisor or Container Engine, a Host OS, and Hardware resources (Compute, Storage, Network). To the right of the stack are three orange blocks: NFVO, VNFM/CNFM, and VIM. Three operators (Operator A, Operator B, Operator C) are shown on the right, with arrows pointing to the VNFM/CNFM block, indicating they interact with the cloud management functions. + +Figure 5-7 : Outsourced community cloud + +#### On-site Community Cloud + +| Cloud type | Cloud model | Hardware | Host OS | Container Engine or Hypervisor | VNFs/CNFs | +|-------------------------|-------------|----------------|-------------------------|--------------------------------|-----------| +| On-site Community Cloud | On-Premise | Operators | Operators | Operators | Operators | +| On-site Community Cloud | IaaS | CSP, Operators | CSP, Operators, Vendors | CSP, Operators, Vendors | Operators | +| On-site Community Cloud | PaaS | CSP, Operators | CSP, Operators, Vendors | CSP, Operators, Vendors | Operators | + +#### Outsourced community cloud + +| Cloud type | Cloud model | Hardware | Host OS | Container Engine or Hypervisor | VNFs/CNFs | +|----------------------|-------------|----------|-------------------------|--------------------------------|-----------| +| Outsourced community | On-Premise | NA | NA | NA | NA | +| Outsourced community | IaaS | CSP | CSP, Operators, Vendors | CSP, Operators, Vendors | Operators | +| Outsourced community | PaaS | CSP | CSP, Operators, Vendors | CSP, Operators, Vendors | Operators | + +### 5.3.3 Public Cloud + +A public cloud is one in which the cloud infrastructure and computing resources are made available to the general public over a public network. A public cloud is owned by an organization providing cloud services, and serves a diverse pool of clients (e.g. Operators, Third parties service providers). + +Figure 5-8 presents a simple view of a public cloud and its actors. + +![Figure 5-8: Public cloud architecture diagram. The diagram shows a 'Public Cloud' box containing a 'Cloud Provider' icon at the top. Below the provider is a stack of layers: 'VNF/CNF' (four instances), 'NFVO', 'Hypervisor or Container Engine', 'VNFM/CNFM', 'Host OS', and 'VIM'. The bottom layer is 'Hardware resources (Compute, Storage, Network)'. On the left, 'Third Party A', 'Third Party B', and 'Third Party C' are shown with arrows pointing to the 'VNF/CNF' layer. On the right, 'Operator A', 'Operator B', and 'Operator C' are shown with arrows pointing to the 'VNFM/CNFM' layer.](7182eca90249220437ad6a5148439651_img.jpg) + +Figure 5-8: Public cloud architecture diagram. The diagram shows a 'Public Cloud' box containing a 'Cloud Provider' icon at the top. Below the provider is a stack of layers: 'VNF/CNF' (four instances), 'NFVO', 'Hypervisor or Container Engine', 'VNFM/CNFM', 'Host OS', and 'VIM'. The bottom layer is 'Hardware resources (Compute, Storage, Network)'. On the left, 'Third Party A', 'Third Party B', and 'Third Party C' are shown with arrows pointing to the 'VNF/CNF' layer. On the right, 'Operator A', 'Operator B', and 'Operator C' are shown with arrows pointing to the 'VNFM/CNFM' layer. + +Figure 5-8 : Public cloud + +| Cloud type | Cloud model | Hardware | Host OS | Container Engine or Hypervisor | VNFs/CNFs | +|------------|-------------|----------|---------|--------------------------------|-----------| +| Public | On-Premise | NA | NA | NA | NA | +| Public | IaaS | NA | NA | NA | Operators | +| Public | PaaS | CSP | CSP | CSP | Operators | + +### 5.3.4 Hybrid Cloud + +A hybrid cloud is a composition of two or more clouds (on-site private, on-site community, off-site private, off-site community or public) that remain as distinct entities but are bound together by standardized or proprietary technology + +that enables data and application portability. Figure 5-9 presents a simple view of a hybrid cloud that could be built with a set of clouds in the five deployment model variants. + +The idea is to combine the benefits of multiple deployment models. The deployment in hybrid clouds could be either a combination of private, public or community clouds. One of the popular use cases of hybrid clouds is in enhancing security and privacy on the cloud without incurring the overhead costs (CAPEX) of building a private cloud. In this case, non-critical resources like test workloads can be hosted in the public cloud, while critical resources like user data and workloads are hosted internally. + +![Figure 5-9: Hybrid cloud architecture diagram showing connections between On-Site Private Cloud, Outsourced Private Cloud, On-site Community Cloud, Outsourced Community Cloud, and Public Cloud, all managed by various operators and third parties.](038812f771996e5ec6ecfe377a66d2e0_img.jpg) + +The diagram illustrates a hybrid cloud architecture connecting five different cloud deployment models. Each cloud model is represented by a box containing a stack of layers: Hardware resources (Compute, Storage, Network) at the base, followed by Host OS, Hypervisor or Container Engine, VNF/CNF (multiple instances), and NFVO at the top. Additional components like VIM, VNFM/CNFM, and VIM are shown on the right side of the stack. + +- On-Site Private Cloud:** Managed by a single **Operator**. +- Outsourced Private Cloud:** Managed by a **Cloud Provider**, with an **Operator** icon shown to the right. +- On-site Community Cloud:** Managed by multiple operators: **Operator A**, **Operator B**, and **Operator C**. It shows nested local clouds for each operator. +- Outsourced Community Cloud:** Managed by a **Cloud Provider**, with **Operator A**, **Operator B**, and **Operator C** icons shown to the right. +- Public Cloud:** Managed by a **Cloud Provider**, with **Third Party A**, **Third Party B**, and **Third Party C** icons on the left, and **Operator A**, **Operator B**, and **Operator C** icons on the right. + +Connections are shown as lines between the cloud boxes, indicating interconnectivity and data flow between the different cloud environments. + +Figure 5-9: Hybrid cloud architecture diagram showing connections between On-Site Private Cloud, Outsourced Private Cloud, On-site Community Cloud, Outsourced Community Cloud, and Public Cloud, all managed by various operators and third parties. + +Figure 5-9 : Hybrid cloud + +## 5.4 High-Level risk assessment + +The following table illustrates the high-level security risk assessment of the cloud deployment models (Private, Community, Public and Hybrid). Colors red, yellow, and green are used on the security risk assessment to indicate high, medium, and low levels of risk. The Cloud Consumer (operator) is accountable for the security posture of the deployment for all cloud deployment models [i.44]. + +| Risks | Private Cloud | Community Cloud | Public Cloud | Hybrid Cloud | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +|

Regulatory Compliance: Risk of non-compliance with regulations on data ownership, geographic location and privacy. Regulatory drift.

Data security and regulatory risk can be associated with loss, leakage, or unavailability of data. This can cause business interruption, loss of revenue, loss of reputation, or regulatory incompliance (e.g. GDPR, HIPAA).

The Cloud Consumer

|

Low Risk: Similar to traditional computing, as operators have better control and understanding on how various government rules, laws, and regulations apply to them. The Cloud Consumer (operator) has control of data and regulatory compliance.

|

Moderate Risk: Cloud Consumer (operator) has better control and understanding on how various government rules, laws, and regulations apply to them. Data leakage or data access risks due to multitenancy/shared infrastructure between different operators.

|

High Risk: Lack of flexibility over data protections mechanisms, such as encryption and implementation of specific controls by data type. Different operators or service providers might have different encryption and control requirements, and a public cloud provider may not be able to customize their infrastructure or provide customers the control over encryption keys.

In some situations, it may be determined that a Cloud Service Provider's cybersecurity tools, processes and methods are insufficient for protecting highly sensitive data. The Cloud Consumer (operator) is responsible for the security configuration of CSP provided applications, tools and services.

|

Moderate Risk: Cloud Consumer (operator) has better control and understanding on how various government rules, laws, and regulations apply to them.

Administrators have more control and flexibility when implementing security. The Cloud Consumer can architect the Hybrid Cloud deployment to ensure regulatory compliance of most sensitive data, while less sensitive data is accessed, stored, and

| + +| | | | | | +|-------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| (operator) is accountable for data, regulatory compliance, and configuration of security controls. | | | The Cloud Consumer (operator) must practice due diligence to assess the regulatory compliance of the Cloud Service Provider's environment. | processed in the Public Cloud.

The Cloud Consumer (operator) must practice due diligence to assess the regulatory compliance of the Cloud Service Provider's environment. | +| Multi-Tenancy:
Risk due to Multi-Tenancy with shared resources. Risks include data leakage, VM Escape, Host Escape, and Hyperjacking. | Low Risk: Private Networks avoid shared resources. | High Risk: Data leakage or access risks due to multitenancy/shared resources for multiple Cloud Consumers (operators) that may be competitors. Cloud Consumer (operator) must ensure security configurations to protect access to network functions, confidentiality and integrity of data in motion, and confidentiality, integrity, and access controls for data at rest. | High Risk: Data leakage or access risks due to multitenancy/shared resources. Cloud Consumer (operator) must ensure security configurations to protect access to network functions, confidentiality and integrity of data in motion, and confidentiality, integrity, and access controls for data at rest. | High Risk: Data leakage or access risks due to multitenancy/shared infrastructure. Cloud Consumer (operator) must ensure security configurations to protect access to network functions, confidentiality and integrity of data in motion, and confidentiality, integrity, and access controls for data at rest. | + +| | | | | | +|---------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +|

Third-Party Administration: Operational risk can be associated with O-RAN network services, lack of control, visibility, etc.

|

Low Risk: With private cloud, the operator gains full control and visibility over its cybersecurity posture and can customize it to fit its specific needs.

Operator has complete visibility, monitoring and control, analyze logs, alerts and other data down to the packet level.

|

Moderate Risk: Security administrators may deal with differing methods and tools to monitor and act on threats depending on where vulnerable resources reside.

Lack of customized security and service level for different O-RAN network services, which might require the operator to choose a proximate acceptable security and service level, including those related to availability and disaster recovery.

|

High Risk: Lack of customized security and service level for different O-RAN network services, which might require the operator to choose a compensating security control and security baseline.

The underlying infrastructure is not managed by the operator, security information may be not accessible.

Reduced control on critical network services can impact availability and disaster recovery. Disaster Recovery with a second CSP, which may not have the same security posture due to use of different security tools and configurations.

|

High Risk: Varying security tools and configurations may not prevent a consistent security baseline across the Hybrid Cloud deployment. The Cloud Consumer may have reduced visibility with the CSP controlled part of the service.

Disaster Recovery should be provided with a second CSP, which may not have the same security posture due to use of different security tools and configurations.

Security roles and responsibilities must be clearly defined and assigned to the Cloud Consumer (operator) and Cloud Service Provider (CSP). The Cloud Consumer (operator) must

| +|---------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | | | | +|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | practice due diligence to ensure a consistent security posture across the Hybrid Cloud deployment. | +|

Technology Evolution:
Technology risk can be associated with constantly evolving technologies and lack of standardization in how they integrate or interoperate. Technology risks could lead to costly rearchitecture efforts for adoption or integration with new technology.

|

High Risk: A constantly evolving technology landscape that might require the operator to upgrade or rearchitect its computing resources and retrain its technology support staff.

A potential for human error due to the number of configurable points and frequency of deployments.

Lack of qualified talent.

|

Moderate Risk: Operators share a common set of security tools, for which each is responsible for properly configuring the security of its tenancy.

Operators can share cloud complexity to manage constantly evolving technology landscape that might require operators to upgrade or rearchitect its computing resources and retrain its technology support staff.

|

Low Risk: Larger CSPs often invest heavily in top-end cybersecurity tools, as well as staff who are highly knowledgeable in their field. This makes offloading cybersecurity tools and tasks from in-house to a third party highly appealing.

Operators can transfer cloud complexity to the CSP, which already has the necessary cloud expertise, infrastructure and systems. For example, faster time-to-market and improved operations efficiency are achieved by taking advantage of CSP-trained talent and their existing CI/CD DevOps, automation, orchestration and analytics capabilities. Operators can then focus on service differentiation, not the underlying cloud platforms.

|

Moderate Risk: Hybrid Cloud deployments provide flexible management of legacy and proprietary applications while enabling use of technologies associated with cloud-based services and applications.

A potential for human error due to the number of configurable points and frequency of deployments. The operator is responsible for properly configuring the security across the Hybrid Cloud. The Cloud Consumer (operator) must

| + +| | | | | | +|----------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | practice due diligence to ensure a consistent security posture across the Hybrid Cloud deployment. | +| Financial costs & operation |

High Risk: Operating private clouds is often a more expensive endeavor than public cloud options. Businesses pay a premium for granular cloud control and visibility.

Designing and maintaining cybersecurity tools inside private clouds dramatically increase management responsibilities.

Lack of Operator-trained administrators.

|

Moderate Risk: Designing and maintaining cybersecurity tools inside community clouds increase management responsibilities.

Lack of Operator-trained administrators.

Operators can share financial cost and the operation of community cloud.

|

Low Risk: Operating public clouds is often a less expensive endeavor than private and community cloud options.

Operators can transfer cloud operation to the CSP, which already has the necessary cloud expertise, infrastructure, and systems.

|

Moderate Risk: Designing and maintaining cybersecurity tools inside hybrid clouds increase management responsibilities.

Operators can transfer part of the cloud operation to the CSP, which already has the necessary cloud expertise, infrastructure, and systems.

| + +1 + +2 Risk levels: High, Moderate, Low + +3 + +**Table 5-1 : High level security risk assessment of cloud deployment models** + +# 6 Roles and responsibilities + +The list of users likely to interact with the O-CLOUD as well as their roles are presented in the table below. The last column distinguishes between stakeholders acting: + +- Under the direct responsibility of an operator or +- Under the responsibility of a third party (e.g. equipment supplier) acting through a contract with the operator. + +The table shows many roles in which the operator and cloud service provider are both stakeholders. This highlights the need to have: + +- Clearly defined and agreed upon roles and responsibilities in the cloud service agreement. +- Separation of Duties enforced by the cloud service provider to limit insider threats. +- Principles of least privilege access control configured and enforced by the operator. + +| Roles | Responsibilities | Stakeholders | +|----------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------| +| O-Cloud Planner | Operator planning O-Cloud instance. | Operator, CSP | +| O-Cloud Installation Manager | Operator designing each O-Cloud instance.

Cloud Installation Manager issues a “service request” to the SMO to update its Inventory, i.e., indicate that a new O-Cloud is to be inventoried. The Cloud Installation Project Manager also registers to the SMO the basic software for the O-Cloud. | Operator, CSP | +| Network Function Install Manager | Operator designing each Network Function instance. | Operator, Vendor | +| O-Cloud Installer | Operator installing O-Cloud Node. He notifies SMO of the new O-Cloud Build

NOTE: Cloud Installer must provide SMO with information to connect with the new O-Cloud Build, including the target O-Cloud Node in the O-Cloud and identity of the basic software for O-Cloud to be loaded on the O-Cloud | Operator, CSP | +| O-Cloud Maintainer | Operator that operates and manages O-Cloud Nodes | Operator | +| Security administrator | They manage component security configuration: configuration of access rights, password and cryptographic key storage system, IPSec parameters, configuring remote access systems, etc.

They hold the root password and the secret encryption root key. | Operator | +| System administrator | They manage “system” components (e.g. back-up, update, configuring system logs, etc.). | Operator | +| O-RAN NF Administrator | They can manage and configure one or more VNFs/CNFs (e.g. Near RT RIC, O-CU, O-DU). They can perform the daily operational tasks (notably provisioning) of NFs. | Operator | +| IMS Administrator | They manage IMS activities. They can perform the daily operational tasks and configure the IMS. They control functions providing access to the IMS. They are responsible for VNFs/CNFs hardware configuration. | Operator, CSP | + +| | | | +|------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| +| DMS Administrator | They manage DMS activities. They can perform the daily operational tasks (notably provisioning) and configure the DMS. They control functions providing access to DMS. | Operator CSP | +| Virtualization layer administrator (Hypervisor/Container Engine) | They manage the virtualization/containerization layer (Hypervisor/Container Engine). They can perform the daily operational tasks (notably provisioning) and configuration of the virtualization layer. They control functions providing access to this layer. | Operator, CSP | +| Compute nodes administrator (physical servers) | They manage compute nodes (physical servers) They can access the node's graphic console, start, stop, restart the node. They can activate/deactivate the node network interfaces and check its status. They manage local storage in compute nodes. | Operator, CSP | +| Storage administrator | They manage shared storage (e.g. images repository) | Operator, CSP | +| Maintainer (equipment supplier or third party) |

They can remotely (e.g. via VPN) or locally access equipment to update, configure, remove or add network applications. They have access to compute node configuration interfaces to update firmware and configure BIOS, CPU, MMU, etc.

The maintainer works on the O-Cloud platform under the control of the operator who (e.g. via IAM: Identity Access Management) creates specific accounts for a limited period.

| Vendor, Third Party | +| Internal validation laboratory | They are responsible for vulnerability scanning, testing, qualifications, security/compliance of network applications before their deployment. | Operator, Vendor, CSP | +| Security Incident Response Team |

Setup a vulnerability management process of monitoring, identifying, evaluating, treating, and reporting on security vulnerabilities and incidents.

Maintenance of the O-Cloud components that includes monitoring for use of open source software with known vulnerabilities and patching for vulnerabilities.

Provide a process for users, including security researchers, to submit bug reports (e.g., using an issue tracker or a mailing list).

| Operator, Vendor, CSP | + +Table 6-1 : List of Users + +# 7 Security Problem Definition + +Before analyzing the way to protect the O-Cloud, it is important to identify the threats affecting the different O-Cloud components and data. + +For this identification of threats, it is essential first to know the critical assets, consisting of anything that has value for within O-Cloud and needs to be protected, and secondly to identify the threat agents, the entities that can adversely act on the asset. + +## 7.1 Assets + +The assets listed below are associated with O-Cloud. They are described in Clause 6.3 of the O-RAN Security Threat Modeling and Risk Assessment [i.50]: + +- ASSET-D-12: O-Cloud Inventory information of hardware resources and software resources +- ASSET-D-13: Functional telemetry: deployment, infrastructure +- ASSET-D-14: O-Cloud Provisioning information, O-Cloud software management information, List of authorized VNF/CNF, VNF/CNF description files +- ASSET-D-15: O-RAN Cloudified Network Function Software Image and metadata, secrets, configuration files +- ASSET-D-16 & ASSET-D-17: Private keys, certificates support for authentication, encryption, signing (e.g. for TLS and similar protocols, image signing) +- ASSET-D-18: Software components at runtime and their associated data, data of VNF/CNF hosted in the shared storage system, RAM and the disk in the compute node +- ASSET-D-20: Credentials (Administrators): account information and passwords +- ASSET-D-29: Security event log files generated by O-Cloud components +- ASSET-D-31: Security telemetry from the NFV system for detecting threats and anomalies +- ASSET-D-32: Cryptographic keys used during secure boot, for encryption/decryption, etc. +- ASSET-D-33: Data in transit AALI-C-Mgmt interface +- ASSET-D-34: Data in transit AALI-C-App & AALI-P interfaces +- ASSET-D-35: Data in transit vendor specific interface +- ASSET-D-36: AAL profiles. It specifies one or more Accelerated Functions that an accelerator processes on behalf of an AAL Application within an O-RAN Network Function in an O-Cloud [i.52]. +- ASSET-D-37: AAL-LPU. It is a logical representation of resources within an instance of a HW Accelerator [i.52]. +- ASSET-D-38: Stored AAL data (e.g., logs, configuration data) +- ASSET-C-08: O-Cloud software including the OS kernel and the virtualisation layer. +- ASSET-C-23: O2, including protocol stack +- ASSET-C-29: AAL Implementation. It is a realization of an AAL including but not limited to the software libraries and drivers [i.52]. +- ASSET-C-30: The hardware accelerator device firmware and hardware. + +The figure below presents a cartography of the assets within the O-Cloud architecture: + +![Figure 7-1: Cartography of O-Cloud assets. This diagram illustrates the architecture and security assets of the O-Cloud. At the top, the SMO (Service Management Orchestrator) contains Non RT RIC/rApps, NFO (Network Function Orchestrator), and FOCOM (Function Configuration and Management). The SMO is connected to an Images repository and an O-Cloud. The O-Cloud contains VNF/CNF (Virtual Network Functions/Cloud Network Functions) and Near RT RIC/xApps. The VNF/CNF layer includes O-DU and O-CU, which are connected to AAL (Application Assurance Layer) components. The Near RT RIC/xApps are connected to the O-Cloud API. The O-Cloud API is connected to the Virtualization Layer (VL). The VL contains Containers, VMs (Virtual Machines), and Guest OS (Guest Operating System). The VL is supported by a Host OS and a Hypervisor (Type I). The Host OS and Hypervisor (Type I) are supported by Hardware resources (Compute, Storage, Network, Hardware Accelerator manager). The diagram also shows various security assets (ASSET-D-31 to ASSET-D-38) and their connections to the O-Cloud components. Red arrows indicate the flow of data and security assets between the SMO, O-Cloud, and the various layers and components.](63744c226c2e4bcadd07a120df3457da_img.jpg) + +**ASSET-D-31:** Security telemetry from the NFV system for detecting threats and anomalies + +**ASSET-D-12:** O-Cloud Inventory information of hardware resources and software resources + +**ASSET-D-13:** Functional telemetry: deployment, infrastructure + +**ASSET-D-14:** O-Cloud Provisioning information, O-Cloud software management information, List of authorized VNF/CNF, VNF/CNF description files + +**ASSET-D-15:** O-RAN Cloudified Network Function Software Image and metadata, secrets, configuration files + +**ASSET-D-16 & ASSET-D-17:** Private keys, certificates support for authentication, encryption, signing (e.g. for TLS and similar protocols, image signing) + +**ASSET-D-20:** Credentials (Administrators): account information and passwords + +**ASSET-D-29:** Security event log files generated by O-Cloud components + +**ASSET-D-32:** Other crypto keys for secure boot, ... + +**ASSET-D-18:** Software components at runtime and their associated data, data of VNF/CNF hosted in the shared storage system, RAM and the disk in the compute node + +**ASSET-D-33:** Data in transit AALI-C-Mgmt interface. + +**ASSET-D-34:** Data in transit AALI-C-App & AALI-P interfaces. + +**ASSET-D-35:** Data in transit vendor specific interface. + +**ASSET-D-36:** AAL profiles. + +**ASSET-D-37:** AAL-LPU. + +**ASSET-D-38:** Stored AAL data (e.g., logs, configuration data). + +Figure 7-1: Cartography of O-Cloud assets. This diagram illustrates the architecture and security assets of the O-Cloud. At the top, the SMO (Service Management Orchestrator) contains Non RT RIC/rApps, NFO (Network Function Orchestrator), and FOCOM (Function Configuration and Management). The SMO is connected to an Images repository and an O-Cloud. The O-Cloud contains VNF/CNF (Virtual Network Functions/Cloud Network Functions) and Near RT RIC/xApps. The VNF/CNF layer includes O-DU and O-CU, which are connected to AAL (Application Assurance Layer) components. The Near RT RIC/xApps are connected to the O-Cloud API. The O-Cloud API is connected to the Virtualization Layer (VL). The VL contains Containers, VMs (Virtual Machines), and Guest OS (Guest Operating System). The VL is supported by a Host OS and a Hypervisor (Type I). The Host OS and Hypervisor (Type I) are supported by Hardware resources (Compute, Storage, Network, Hardware Accelerator manager). The diagram also shows various security assets (ASSET-D-31 to ASSET-D-38) and their connections to the O-Cloud components. Red arrows indicate the flow of data and security assets between the SMO, O-Cloud, and the various layers and components. + +Figure 7-1 : Cartography of O-Cloud assets + +## 7.2 Threats + +The complexity and the extension of attack surface of a virtualized environment increase the difficulty to list, in an exhaustive manner, the security threats to which the O-Cloud assets are exposed. For this activity of threat analysis, some reports have been used to help the identification of a large number of these threats: + +- CISA/NSA - Kubernetes Hardening Guidance [i.3] +- MITRE ATT&CK containers matrix [i.4] +- ENISA Threat Landscape for 5G Networks: Threat assessment for the fifth generation of mobile telecommunications networks (5G) [i.5] +- ETSI Secure End-to-End VNF and NS management specification Secure End-to-End VNF and NS management specification [i.6] + +The following table is the template used to present the threat characteristics: + +| | | +|------------------------------|---------------------------------------------------------------------------------------------------------------| +| Threat ID | Unique identification per Threat (e.g. T-XX-01) | +| Threat title | Title of the threat | +| Threat description | Description of the Threat | +| Threat type | Spoofing
Tampering
Repudiation
Information disclosure
Denial of Service
Elevation of Privilege | +| Vulnerabilities | What vulnerabilities can the threat exploits? | +| Impact type | Authenticity
Integrity
Non-repudiability
Confidentiality
Availability
Authorization | +| Threatened Assets | Impacted Asset(s) (Data & Component) | +| Affected Services | What services (from section 4.3) could be affected by this Threat | +| Potential mitigations | Mitigation measures to address the threat | + +### 7.2.1 Threat and impact types + +For identifying threats, we are using STRIDE: + +1. S - Spoofing identity. An application or program can masquerade as another to gain advantages not typically allowed for that program. + +2. T - Tampering with data. This involves the malicious modification of data, including making unauthorized changes to a database and alteration of data as it flows between computers. +3. R - Repudiation. A user or program refuses the authenticity of a good or reasonable command or action. +4. I - Information disclosure. This involves the exposure of information to individuals with unauthorized access to it. For example, users gain the ability to read a file that they normally would not have been granted access to, or an intruder can read data in transit between computers. +5. D - Denial of service. These attacks deny service to valid users, such as making a website unavailable or unusable by flooding it with illegitimate requests to keep legitimate users without access. +6. E - Elevation of privileges. An unauthorized user gains privileged rights to access previously no granted to compromise or destroy the system, such as a change in membership. + +| Threat types | Impact types | +|------------------------|-------------------| +| Spoofing | Authenticity | +| Tampering | Integrity | +| Repudiation | Non-repudiability | +| Information disclosure | Confidentiality | +| Denial of Service | Availability | +| Elevation of Privilege | Authorization | + +### 7.2.2 Attack surface + +An attack surface of a system refers to the set of various entry points that can be exploited. The various components that compose the attack surface of the O-Cloud are depicted in the following figure. They are as follows: + +- 1) VNFs/CNFs: O-DU, O-CU, O-RU, Near RT-RIC/xApps +- 2) Images repository with its interface to O-Cloud +- 3) Virtualization layer: Hypervisor and/or Container Engine, Host OS +- 4) Hardware resources including compute, storage, network, and hardware accelerator manager +- 5) O-Cloud API +- 6) O2dms and O2ims interfaces +- 7) NFO and Federated O-Cloud O&M (FOCOM) within the SMO +- 8) AAL + +The attack vectors for exploiting vulnerabilities of these components are discussed in detail in the threat events sections. + +![Figure 7-2: Attack vectors. This diagram illustrates the O-Cloud architecture and its attack vectors. The O-Cloud is divided into several layers: VNF/CNF (containing O-DU, O-CU, and Near RT RIC/xApps), Virtualization Layer (VL) (containing Containers, VMs, Container Engine, Hypervisor (Type II), Guest OS, and Hypervisor (Type I)), and Hardware resources (Compute, Storage, Network, Hardware Accelerator manager). The SMO (Service Management and Orchestration) layer is at the top, containing Non RT RIC/rApps, NFO, and FOCOM. The Images repository is connected to the SMO and the O-Cloud. Attack vectors are numbered 1 through 8: 1. Near RT RIC/xApps; 2. Images repository; 3. Virtualization Layer (VL); 4. Hardware resources; 5. O-Cloud API; 6. FOCOM; 7. NFO; 8. AAL (Application Assurance Layer).](37d86aea722a87033aab14333c50bd9c_img.jpg) + +Figure 7-2: Attack vectors. This diagram illustrates the O-Cloud architecture and its attack vectors. The O-Cloud is divided into several layers: VNF/CNF (containing O-DU, O-CU, and Near RT RIC/xApps), Virtualization Layer (VL) (containing Containers, VMs, Container Engine, Hypervisor (Type II), Guest OS, and Hypervisor (Type I)), and Hardware resources (Compute, Storage, Network, Hardware Accelerator manager). The SMO (Service Management and Orchestration) layer is at the top, containing Non RT RIC/rApps, NFO, and FOCOM. The Images repository is connected to the SMO and the O-Cloud. Attack vectors are numbered 1 through 8: 1. Near RT RIC/xApps; 2. Images repository; 3. Virtualization Layer (VL); 4. Hardware resources; 5. O-Cloud API; 6. FOCOM; 7. NFO; 8. AAL (Application Assurance Layer). + +Figure 7-2 : Attack vectors + +### 7.2.3 Vulnerabilities + +The following figure highlights the main vulnerabilities that may emerge within the attack vectors (see Figure 7-2). + +![Figure 7-3: Vulnerabilities within O-Cloud. This diagram shows the vulnerabilities within the O-Cloud architecture. The O-Cloud is divided into three main components: Near RT RIC, O-CU, and O-DU, which are managed by the Hypervisor or Container Engine. The Host OS is at the bottom. The Images repository is connected to the O-Cloud. Vulnerabilities are highlighted with arrows pointing to the relevant components: 1. Vulnerable code exploits: Design weakness, Lack of authentication, Lack of integrity verification during boot or runtime, Insecure data storage. 2. Misconfiguration or Insecure VM/Container configurations: Points to the Near RT RIC, O-CU, and O-DU. 3. Insecure networking: Unrestricted communication between VMs/Containers. 4. Shared tenancy vulnerabilities: Lack of strong VM/Container isolation. 5. Hypervisor/Container Engine misconfiguration. 6. Host misconfiguration. 7. Secret exposure. 8. Compromised VM/Container images at rest or in transit. 9. Insecure data storage. 10. Lack authentication. 11. Misconfiguration or Insecure VM/Container images configurations.](e899bbff8ffea1398658ceb611748bf1_img.jpg) + +Figure 7-3: Vulnerabilities within O-Cloud. This diagram shows the vulnerabilities within the O-Cloud architecture. The O-Cloud is divided into three main components: Near RT RIC, O-CU, and O-DU, which are managed by the Hypervisor or Container Engine. The Host OS is at the bottom. The Images repository is connected to the O-Cloud. Vulnerabilities are highlighted with arrows pointing to the relevant components: 1. Vulnerable code exploits: Design weakness, Lack of authentication, Lack of integrity verification during boot or runtime, Insecure data storage. 2. Misconfiguration or Insecure VM/Container configurations: Points to the Near RT RIC, O-CU, and O-DU. 3. Insecure networking: Unrestricted communication between VMs/Containers. 4. Shared tenancy vulnerabilities: Lack of strong VM/Container isolation. 5. Hypervisor/Container Engine misconfiguration. 6. Host misconfiguration. 7. Secret exposure. 8. Compromised VM/Container images at rest or in transit. 9. Insecure data storage. 10. Lack authentication. 11. Misconfiguration or Insecure VM/Container images configurations. + +Figure 7-3 : Vulnerabilities within O-Cloud + +### 7.2.4 Threat events + +The following threats to O-Cloud have been identified and are analyzed in this Clause. Other threats within the attack vectors ④, ⑥, ⑦ ⑧ will be added in future versions of the report. + +| Threat | Threat Title | +|------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------| +| Generic Threats | | +| T-GEN-01 | Software flaw attack | +| T-GEN-02 | Malicious access to exposed services using valid accounts | +| T-GEN-03 | Untrusted binding between the different O-Cloud layers | +| T-GEN-04 | Lack of Authentication & Authorization in interfaces between O-Cloud components | +| T-GEN-05 | Unsecured credentials and keys | +| T-GEN-06 | Sensitive application data cache exploitation | +| Threats concerning VMs/Containers | | +| T-VM-C-01 | Abuse of a privileged VM/Container | +| T-VM-C-02 | VM/Container escape attack | +| T-VM-C-03 | VM/Container data theft | +| T-VM-C-04 | VM/Container migration attacks | +| T-VM-C-05 | Changing virtualization resource without authorization | +| T-VM-C-06 | Failed or incomplete VNF/CNF termination or releasing of resources | +| Threats concerning VM/Container images | | +| T-IMG-01 | VM/Container images tampering | +| T-IMG-02 | Insecure channels with images repository | +| T-IMG-03 | Secrets disclosure in VM/Container images | +| T-IMG-04 | Build image on VL | +| Threats concerning the virtualization layer (Host OS-Hypervisor/Container engine) | | +| T-VL-01 | VM/Container hyperjacking attack | +| T-VL-02 | Boot tampering | +| T-VL-03 | Attack internal network services | +| Threats concerning O-Cloud interfaces | | +| T-O2-01 | MitM attacks on O2 interface between O-Cloud and SMO | +| T-OC-API-01 | MitM attacks on O-Cloud interface between VNFs/CNFs and the virtualization layer | +| Threats concerning hardware resources | | +| T-HW-01 | Cross VM/Container side channel attacks | + +| | | +|----------------------------------------------------------------|---------------------------------------------------------------------------------| +| T-HW-02 | MitM attacks on the interface between virtualization layer and hardware | +| Threats concerning O-Cloud management (SMO, NFO, FOCOM) | | +| T-ADMIN-01 | Denial of service against NFO/FOCOM | +| T-ADMIN-02 | Abuse an O-Cloud administration service | +| Threats concerning Acceleration Abstraction Layer (AAL) | | +| T-AAL-01 | Attacker exploits insecure API to gain access to hardware accelerator resources | +| T-AAL-02 | Internal Overload DoS attack targeting AAL services | +| T-AAL-03 | Fail to clear resources | +| T-AAL-04 | HAM compromise | +| T-AAL-05 | Malicious memory accesses | +| T-AAL-06 | Firmware attacks | +| Threats concerning O-Cloud instance ID | | +| T-O-CLOUD-ID-01 | ID reuse in O-Cloud's object lifecycle | +| T-O-CLOUD-ID-02 | Node redundancy in O-Cloud deployments | +| T-O-CLOUD-ID-03 | O-Cloud ID mismanagement | +| Threats concerning time synchronization | | +| T-TS-01 | Time synchronization disruption in O-Cloud | + +#### 7.2.4.1 Generic Threats + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-01 | +| Threat title | Software flaw attack | +| Threat description |

Code of host OS, Hypervisor/Container Engine and VNF/CNF can include flaws that an attacker can exploit if they are present.

O-RAN software components rely on opensource software, opensource libraries, 3rd party components. Vulnerability in any of these software components likely to allow attacker to exploit O-CLOUD environment. This could lead attacker to carry out to malicious activities, such as:

  • • Compromise of the underlying VM/Container
  • • Exploit host access via Escape to Host
  • • Take advantage of weak identity and access management policies to attempt to elevate privileges
  • • Execute adversary-controlled code
  • • Enable an adversary to move from a virtualized environment, such as within a virtual machine or container, onto the underlying host
| + +| | | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat type | Spoofing, Tampering, Information disclosure, Elevation of Privilege | +| Vulnerabilities | Vulnerable code exploits, Design Weakness | +| Impact type | Authenticity, Integrity, Confidentiality, Authorization | +| Threatened Assets | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | All services | +| Potential mitigations |

REC-IMGP Image protection

REC-VHPM Vulnerability Handling and Patch Management

REC-SDLC Secure Development Lifecycle

REC-LOG Logging, Monitoring and Alerting

REC-ISO Strong Isolation

REC-AUD Security Audit

| + +| | | +|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-02 | +| Threat title | Malicious access to exposed services using valid accounts | +| Threat description |

Access to valid accounts to use the O-Cloud services is often a requirement, which could be obtained through credential pharming or by obtaining the credentials from users after compromising the network.

Adversaries may obtain and abuse credentials of existing accounts as a means of gaining initial access, persistence, privilege escalation, or defense evasion. Compromised credentials may be used to bypass access controls placed on various resources on O-Cloud.

Compromised credentials may also grant an adversary increased privilege to specific O-Cloud services or access to restricted areas of the O-Cloud network.

Access may be also gained through an exposed service that doesn't require authentication. In containerized environments, this may include an exposed Docker API, Kubernetes API server, kubelet, or web application such as the Kubernetes dashboard.

| +| Threat type | Spoofing, Tampering, Information disclosure, Elevation of Privilege | +| Vulnerabilities | Lack of authentication | +| Impact type | Authenticity, Integrity, Confidentiality, Authorization | +| Threatened Assets | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | All services | +| Potential mitigations |

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-LOG Logging, Monitoring and Alerting

REC-NS Network Segmentation & Filter Network Traffic

REC-AUD Security Audit

| + +| | | +|------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-03 | +| Threat title | Untrusted binding between the different O-Cloud layers | +| Threat description |

One major challenge in virtualized architectures and especially in O-Cloud is to prove that a particular VM/Container runs on top of a specific Hypervisor/Container Engine. More specifically, it is necessary to assure that a trusted VM/Container is executed on a particular trusted Hypervisor/Container Engine, whereas the Hypervisor/Container Engine's trust state relies on an attestation that considers the entire corresponding hard and software stack. More precisely, this includes all hardware chips, firmware, OS and Hypervisor/Container Engine components that are relevant for the Hypervisor/Container Engine's trust state determination.

If it is not possible to establish a correlation between VM/Container and Hypervisor/Container Engine, an attacker is able to make use of a trusted VM/Container that runs on top of an untrusted Hypervisor/Container Engine and it would be impossible to detect any interference made by the malicious Hypervisor/Container Engine, e.g. intercepting communication, replacing strong or using weak cryptographic keys, etc. Similarly, trustworthiness in the service-layer might only be established if there is a mechanism to determine that only trusted VNFs/CNFs, w.r.t trusted VM/Container's, are running on specific trusted Hypervisors/Container Engines that are part of the service-provisioning-chain.

| +| Threat type | Tampering, Information disclosure | +| Vulnerabilities | Lack of integrity verification during boot or runtime | +| Impact type | Integrity, Confidentiality | +| Threatened Assets | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | All services | +| Potential mitigations |

REC-IMGP Image protection

REC-LOG Logging, Monitoring and Alerting

REC-RA Remote Attestation

REC-SB Secure Boot

REC-SNFLC Security VNF/CNF lifecycle

| + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-04 | +| Threat title | Lack of Authentication & Authorization in interfaces between O-Cloud components | +| Threat description |

O-Cloud deploys CNF applications as containers in a cluster of physical nodes which may be spanned across geographical locations. Owing to the Service Based Architecture of CNFs, this introduces several service endpoints communicating across each other over the network (container to container, container to cloud infrastructure component) and it is difficult to distinguish between a service terminating an external interface and a service exposing only an internal interface.

Multi-tenant deployments and deployments in public cloud also require the CNF applications to run alongside unknown entities. In such deployment scenarios, CNF service endpoints with no authentication/weak authentication expose risk of attack that can impact the availability of service and the CNF.

Lack of proper authentication in interfaces exposed by CNF services, introduces threats of lateral movement where a compromised container/rogue container:

| + +| | | +|------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |
  • Can compromise the availability of internal service by bringing down the internal service and perform lateral movement of attack by exploiting the availability of other such services
  • Can compromise the confidentiality of the internal service by extracting critical application data
| +| Threat type | Information disclosure, Denial of Service | +| Vulnerabilities | Lack of authentication, Insecure interfaces | +| Impact type | Availability, Confidentiality | +| Threatened Assets | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | All services | +| Potential mitigations | REC-IAM Identity, Authentication, and Access Management
REC-CM Certificate management | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-05 | +| Threat title | Unsecured credentials and keys | +| Threat description |

Adversaries may search compromised O-RAN NFs, VL, orchestration layer or hardware to find and obtain insecurely stored credentials. These credentials can be stored and/or misplaced in many locations on the O-cloud platform, including plaintext files (e.g. Bash History), operating system or application-specific repositories (e.g. Credentials in Registry), or other specialized files/artifacts (e.g. Private Keys) [i.4].

Bash History1: Adversaries may search the bash command history on compromised systems for insecurely stored credentials.

Credentials in registry2: Adversaries may search the Registry on compromised systems for insecurely stored credentials.

Private Keys3: Adversaries may search for private key certificate files on compromised systems for insecurely stored credentials. Private cryptographic keys and certificates are used for authentication, encryption/decryption, and digital signatures; Common key and certificate file extensions include: .key, .pgp, .gpg, .ppk., .p12, .pem, .pfx, .cer, .p7b, .asc.

Adversary tools have been discovered that search compromised systems for file extensions relating to cryptographic keys and certificates.

| +| Threat type | Tampering, Information disclosure, and Elevation of privilege | +| Vulnerabilities | Lack of authentication, secret exposure (insufficient safeguarding of credentials) | +| Impact type | Integrity, Confidentiality, Authorization | +| Threatened Assets | Private keys and credentials | +| Affected Services | All services | + +1 +2 +3 + +| | | +|------------------------------|--------------------------------------------------------------------------------------------------------------| +| Potential mitigations |

REC-SS Secure Storage

REC-PHY Physical Security Protection

REC-SDD Secure data deletion

| +|------------------------------|--------------------------------------------------------------------------------------------------------------| + +| | | +|------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-06 | +| Threat title | Sensitive application data cache exploitation | +| Threat description |

Most of the applications use data that is sensitive in nature which needs to be secured. And it is common for these applications to cache such sensitive data, after retrieving the data from a secure storage. This caching occurs in various forms: within application memory, in persistent file systems, or in ephemeral file systems (For example, non-persistent container file system).

For a VNF, the application can cache the sensitive data in its memory which is non-persistent (erased when the application ceases to exist) or in the persistent virtual machine file system.

For a CNF, the application can store the sensitive data in its memory which is non-persistent (erased when the application/microservice ceases to exist) or in the non-persistent container file system, or in the persistent host file system, provided the application has the necessary privileges to access host file system.

The storage of sensitive data (For example, certificates and private keys or session keys) in the application cache is used to improve performance of the applications and keeping the sensitive information readily available to the applications for faster initialization, re-initialization or recovery.

An example of faster recovery/re-initialization is a scenario where a TLS client establishes a TLS session with a server and stores the client certificate and corresponding private key in the application cache. If the TLS session is terminated unexpectedly (For example, due to network error conditions), the TLS client uses the cached client certificates and private key for recovering / re-establishing the TLS session, instead of retrieving the information from a more secure, but slower, storage solution.

While leveraging application cache is indispensable for significant performance gains, it also presents a notable security risk [i.59][i.60]. The sensitive data stored in application cache would be a primary target from attackers/threat actors [i.61], who can exploit this information to penetrate deeper into O-RAN network functions.

To counter this threat, a “Defense in depth” approach is essential. This approach encompasses multiple security layers designed to mitigate risks associated with application caches, focusing on strong encryption, strict access management and anomaly detection to protect sensitive data effectively.

| +| Threat type | Tampering, Information disclosure | +| Vulnerabilities | Secret exposure (insufficient safeguarding of credentials, etc.) | +| Impact type | Integrity, Confidentiality | +| Threatened Assets | Certificates, private keys, credentials and other application specific sensitive data | +| Affected Services | All services | +| Potential mitigations |

REC-NS Network Segmentation & Filter Network Traffic

REC-LOG Logging, Monitoring and Alerting

REC-SDD Secure data deletion

| + +| | | +|--|-----------------------| +| | REC-SS Secure Storage | +|--|-----------------------| + +#### 7.2.4.2 Threats concerning VMs/Containers + +| | | +|------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VM-C-01 | +| Threat title | Abuse of a privileged VM/Container | +| Threat description |

It's possible to run VMs/Containers with unintended configurations. Such misconfigurations can help the adversaries to compromise even strongest of VM/Container isolation measures.

Such misconfigurations scenarios include:

  • • VMs/Containers can be configured to have more privileges than what is actually required (e.g. settings that give it unnecessary, and perhaps unplanned, privileges). For example, an attacker with access to such a container, can use it to gain higher privileges on host, perform un-authorized operations and get to anything that the host, or any of the containers running on that host, can reach.
  • • VMs/Containers have unintended read/write access to a directory on host filesystem. This could allow an attacker to perform unauthorized modifications to the contents, create symbolic links to any directories or files not directly exposed by the hostPath, install SSH keys, read secrets mounted to the host, and take other malicious actions.
| +| Threat type | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | +| Vulnerabilities | Misconfiguration or Insecure VM/Container configurations | +| Impact type | Authenticity, Integrity, Confidentiality, Availability and Authorization | +| Threatened Assets | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | SERV#01, SERV#03, SERV#04, SERV#05, SERV#06, SERV#07 | +| Potential mitigations |

REC-SCONF Security Configuration

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-ISO Strong Isolation

REC-SNFLC Security VNF/CNF lifecycle

REC-NS Network Segmentation & Filter Network Traffic

REC-SS Secure Storage

REC-ADMC Admission Control Service

| + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VM-C-02 | +| Threat title | VM/Container escape attack | +| Threat description | VNF/CNF deployed on the same physical machine as tenants share the same host kernel and host OS resources. Lack of strong isolation between the VMs/Containers and the host allows for a potential risk of a rogue VM/Container escaping the VM/Container confinement and impacting other co-hosted VMs/Containers. In others, an attacker may deploy a new malicious | + +| | | +|------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |

VM/Container configured without network rules, user limitations, etc. to bypass existing defenses within O-Cloud infrastructure.

Attacker deploys malicious VM/Container to escape the host (Hypervisor/Container Engine/Host OS) and reach the server's hardware, then the malicious VM/Container can gain root access to the whole server where it resides. This gives the malicious VM/Container full control on all the VMs/Containers hosted on the same hacked server. This could allow an attacker to undermine the confidentiality, integrity and/or availability of VNFs/CNFs resources.

Containers can be deployed by various means, such as via Docker's create and start APIs or via a web application such as the Kubernetes dashboard or Kubeflow. Adversaries may deploy containers based on retrieved or built malicious images or from benign images that download and execute malicious payloads at runtime.

When a malicious VM/Container escapes isolation, it can gain full control over the underlying host and cause any of the below serious threats:

  • • Attacker would gain the ability to mount attacks on the host or compromise the host functionalities
  • • Compromise the confidentiality & integrity of co-hosted VMs/Containers and tenants
  • • Launch DDOS attacks on co-hosted VMs/Containers and host services thereby degrading their performance
  • • Introduce new vulnerabilities in host to be used for future attacks
  • • Lack of network segmentation could potentially expose other VMs/Containers in the environment to attack. An example of this could be reconnaissance, exploitation and subsequent lateral movement to another host within the cluster.
| +| Threat type | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | +| Vulnerabilities | Shared tenancy vulnerabilities (multitenant environment), Lack of strong VM/Container isolation, lack of authentication, Insecure networking, Unrestricted communication between VMs/Containers | +| Impact type | Authenticity, Integrity, Confidentiality, Availability and Authorization | +| Threatened Assets | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | SERV#01, SERV#03, SERV#04, SERV#05, SERV#06, SERV#07 | +| Potential mitigations |

REC-ISO Strong Isolation

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-NS Network Segmentation & Filter Network Traffic

REC-LOG Logging, Monitoring and Alerting

REC-SCONF Security Configuration

REC-SNFLC Security VNF/CNF lifecycle

REC-SS Secure Storage

| + +![Figure 7-4: Illustration of the VM/Container escape attack. The diagram shows a layered architecture. At the top, three boxes represent 'VM (s)/Container(s)' containing 'Near RT RIC', 'O-CU', and 'O-DU'. Below these is the 'Hypervisor or Container Engine', followed by the 'Host OS', and at the bottom, 'Hardware resources'. A red arrow labeled '1' points down from the top into the 'Near RT RIC'. A red arrow labeled '2' points down from the 'Near RT RIC' through the 'Hypervisor or Container Engine' and 'Host OS' to the 'Hardware resources'. A red arrow labeled '3' points up from the 'Hardware resources' through the 'Host OS' and 'Hypervisor or Container Engine' to the 'Near RT RIC'. A red arrow labeled '4' points up from the 'Hardware resources' through the 'Host OS' and 'Hypervisor or Container Engine' to the 'O-CU'. Another red arrow labeled '4' points up from the 'Hardware resources' through the 'Host OS' and 'Hypervisor or Container Engine' to the 'O-DU'. Small bug icons are placed on the 'Near RT RIC' and 'Hardware resources' layers.](22d83a70a194ee454b2e949b047c02b5_img.jpg) + +Figure 7-4: Illustration of the VM/Container escape attack. The diagram shows a layered architecture. At the top, three boxes represent 'VM (s)/Container(s)' containing 'Near RT RIC', 'O-CU', and 'O-DU'. Below these is the 'Hypervisor or Container Engine', followed by the 'Host OS', and at the bottom, 'Hardware resources'. A red arrow labeled '1' points down from the top into the 'Near RT RIC'. A red arrow labeled '2' points down from the 'Near RT RIC' through the 'Hypervisor or Container Engine' and 'Host OS' to the 'Hardware resources'. A red arrow labeled '3' points up from the 'Hardware resources' through the 'Host OS' and 'Hypervisor or Container Engine' to the 'Near RT RIC'. A red arrow labeled '4' points up from the 'Hardware resources' through the 'Host OS' and 'Hypervisor or Container Engine' to the 'O-CU'. Another red arrow labeled '4' points up from the 'Hardware resources' through the 'Host OS' and 'Hypervisor or Container Engine' to the 'O-DU'. Small bug icons are placed on the 'Near RT RIC' and 'Hardware resources' layers. + +Figure 7-4 : Illustration of the VM/Container escape attack + +| | | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VM-C-03 | +| Threat title | VM/Container data theft | +| Threat description |

The VNF/CNF remotely stores sensitive data (e.g. passwords, private keys, subscription data, logs) on the logical volume that the IMS/DMS allocates to the VNF/CNF. An attacker can retrieve/manipulate these data if they have been stored in an insecure way (e.g. clear text, unsalted hashes) or a malware is installed on the logical volume that the VIM allocates to the VNF/CNF.

Container example: Adversaries may attempt to discover containers and other resources that are available locally within O-Cloud. Other resources may include images, deployments, pods, nodes, and other information such as the status of a cluster. These resources can be viewed within web applications such as the Kubernetes dashboard or can be queried via the Docker and Kubernetes APIs. In Docker, logs may leak information about the environment, such as the environment's configuration, which services are available, and what cloud provider the victim may be utilizing. The discovery of these resources may inform an adversary's next steps in the environment, such as how to perform lateral movement and which methods to utilize for execution.

| +| Threat type | Tampering, Information disclosure | +| Vulnerabilities | Lack of authentication, insecure data storage | +| Impact type | Integrity, Confidentiality | +| Threatened Assets | Images, environment's configuration, and other information such as the status of a cluster | +| Affected Services | SERV#01, SERV#02 | +| Potential mitigations |

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-NS Network Segmentation & Filter Network Traffic

REC-LOG Logging, Monitoring and Alerting

REC-PHY Physical Security Protection

REC-SS Secure Storage

REC-SDD Secure data deletion

| + +| | | +|------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VM-C-04 | +| Threat title | VM/Container migration attacks | +| Threat description |

The attacks that exploit VM/Container migration can be divided into two subcategories based on the target plane:

  1. 1. Control Plane Attacks: These attacks target the module that is responsible for handling the migration process on a server which is called the migration module that is found in the host. By exploiting a bug in the migration module software, the attacker can hack the server and take full control over the migration module. This gives the attacker the ability to launch malicious activities including the following:
    1. a. Migration Flooding: The attacker moves all the VMs/Containers that are hosted on the hacked server to a victim server that does not have enough resource capacity to host all the moved VMs/Containers. This causes a denial of service for the VNFs/CNFs running in the VMs/Containers of the victim server as there will not be enough resources to satisfy the demands of all the hosted VMs/Containers leading into VM/Container performance degradation and VM/Container crashes.
    2. b. False Resource Advertising: The hacked server claims that it has a large resource slack (a large amount of free resources). This attracts other servers to off-load some of their VMs/Containers to the hacked server so that the O-Cloud workload gets distributed over the O-Cloud servers. After moving VMs/Containers from other servers to the hacked server, the attacker can exploit other vulnerabilities to break into the offloaded VMs/Containers as now these VMs/Containers are placed on a server that is under the control of the attacker.
  2. 2. Data Plane Attacks: These constitute the second type of VM/Container migration attacks and those attacks target the network links over which the VM/Container is moved from a server to another. Such data plane attacks include the MitM where an attacker sniffs the packets that are exchanged between the source and destination servers and reads the migrated memory pages. The attacker can monitor and/or modify the received packets while continuing to forward them to victim VM/Container resides so that the victim does not detect that any malicious activity is going on.
| +| Threat type | Tampering, Information disclosure, Denial of Service | +| Vulnerabilities | Host misconfiguration, lack of authentication, memory pages copied in clear, vulnerable code exploits | +| Impact type | Integrity, Confidentiality, Availability | +| Threatened Assets | VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | SERV#03, SERV#04, SERV#05, SERV#06, SERV#07 | +| Potential mitigations |

REC-CM Certificate management

REC-NS Network Segmentation & Filter Network Traffic

REC-IAM Identity, Authentication and Access Management

REC-SNFLC Security VNF/CNF lifecycle

REC-LOG Logging, Monitoring and Alerting

REC-RA Remote Attestation

| + +![Figure 7-5: Illustration of the migration flooding attack. The diagram shows an attacker (1) sending a flood of migration requests (3) to a server with a hacked migration module. The server's Hypervisor or Container Engine (2) is overwhelmed, leading to a migration flooding attack. The victim server is shown with its own Hypervisor or Container Engine and Migration module.](5f51fe277c7a63979a37743da8790e2b_img.jpg) + +Attacker migrates more VMs/Containers than the capacity of the victim server + +1: Attacker sends migration request + +2: Hypervisor or Container Engine + +3: Attacker migrates more VMs/Containers than the capacity of the victim server + +Server with hacked migration module + +Victim server + +Figure 7-5: Illustration of the migration flooding attack. The diagram shows an attacker (1) sending a flood of migration requests (3) to a server with a hacked migration module. The server's Hypervisor or Container Engine (2) is overwhelmed, leading to a migration flooding attack. The victim server is shown with its own Hypervisor or Container Engine and Migration module. + +Figure 7-5 : Illustration of the migration flooding attack + +![Figure 7-6: Illustration of the false resource advertising attack. The diagram shows an attacker (1) sending a false resource advertisement (2) to a server with a hacked migration module. The server's Hypervisor or Container Engine (3) is misled, leading to a false resource advertising attack. The victim server is shown with its own Hypervisor or Container Engine and Migration module.](3f57a7cfbbec9f807595d918379bc92c_img.jpg) + +1: Attacker sends false resource advertisement + +2: Hypervisor or Container Engine + +3: Hypervisor or Container Engine + +4: Attacker sends false resource advertisement + +Server with hacked migration module + +Victim server + +Figure 7-6: Illustration of the false resource advertising attack. The diagram shows an attacker (1) sending a false resource advertisement (2) to a server with a hacked migration module. The server's Hypervisor or Container Engine (3) is misled, leading to a false resource advertising attack. The victim server is shown with its own Hypervisor or Container Engine and Migration module. + +Figure 7-6 : Illustration of the false resource advertising attack + +![Figure 7-7: Illustration of the migration MITM attack. The diagram shows an attacker (1) intercepting a migration request (2) between a user and a victim server. The attacker's Hypervisor or Container Engine (3) is involved in the migration process, leading to a migration MITM attack. The victim server is shown with its own Hypervisor or Container Engine and Migration module.](b1ece3c05d1bc8678bbe34e666d99de5_img.jpg) + +1: Attacker intercepts migration request + +2: User sends migration request + +3: Hypervisor or Container Engine + +Hacked Server + +Victim server + +Figure 7-7: Illustration of the migration MITM attack. The diagram shows an attacker (1) intercepting a migration request (2) between a user and a victim server. The attacker's Hypervisor or Container Engine (3) is involved in the migration process, leading to a migration MITM attack. The victim server is shown with its own Hypervisor or Container Engine and Migration module. + +Figure 7-7 : Illustration of the migration MITM attack + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VM-C-05 | +| Threat title | Changing virtualization resource without authorization | +| Threat description | IMS/DMS which manage the Virtualization layer is responsible for assigning virtualized resource as requested. | + +| | | +|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |

There are several ways to cause a DoS attack for the VNFs/CNFs:

  • • If IMS/DMS are compromised or the O2 interface is not securely protected, an attacker who compromised the IMS/DMS or breached the O2 interface can change the virtualized resource used by a VNF/CNF by manipulating the allocation of virtualized resource. For example, when an instantiated VNF/CNF is running, adversaries having access to a compromised IMS/DMS or adversaries breaching the insecure O2 interface can misguide the Virtualization layer to reduce the resource of or delete a VM/Container on which a VNF/CNF is running. This can result in the reliability, availability or even illegal termination of a VNF/CNF and hence the denial of service.
  • • Hardware resource configuration and state information (e.g. events) exchange is performed through O2 interface. If the IMS is compromised or the O2 interface is not securely protected, an attacker who compromised the IMS or breached the O2 interface can tamper the hardware configuration and state information so that the virtualized resource supported by the hardware layer becomes unreliable.
  • • Adversaries having access to a compromised virtualization layer can change the virtualization resource used by the instantiated VNF/CNF without authorization,
  • • A malicious VM/Container deployed for one instance of a VNF/CNF on a host can illegally occupy the resources of the instantiated VNF/CNF deployed on the same host, resulting in resource limitation of the instantiated VNF/CNF

In this type of attacks, the extra allocation of resources for the malicious VM/Container comes at the expense of the other VMs/Containers that share the same server as the malicious VM/Container, where these victim VMs/Containers get allocated less share of resources than what they should actually obtain, which in turn degrades their performance.

| +| Threat type | Denial of Service | +| Vulnerabilities | Insecure O1/O2 interfaces, Lack of authentication/access control on IMS/DMS | +| Impact type | Availability | +| Threatened Assets | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | SERV#01 | +| Potential mitigations |

REC-LOG Logging, Monitoring and Alerting

REC-CM Certificate management

REC-IAM Identity, Authentication and Access Management

REC-ISO Strong Isolation

REC-PHY Physical Security Protection

REC-AUD Security Audit

| + +![Figure 7-8: Illustration of the Theft-of-Service/DoS Attack. The diagram shows a stack of layers: Hardware resources at the bottom, followed by Host OS, Hypervisor or Container Engine, and three VM(s)/Container(s) layers above. The VM layers are labeled Near RT RIC, O-CU, and O-DU. A red arrow labeled '1' points from an attacker icon to the O-DU layer. A red arrow labeled '2' points from the O-DU layer to the Hypervisor or Container Engine layer. A red arrow labeled '3' points from the Hypervisor or Container Engine layer to the Host OS layer. The Host OS layer is divided into two sections: 'Malicious VM/Container running' (red) and 'Victim VM/Container running' (black). The O-DU layer also has a red section labeled 'Victim VM/Container running'.](6c015df514d9b4662a431f1a7fcb67cf_img.jpg) + +Figure 7-8: Illustration of the Theft-of-Service/DoS Attack. The diagram shows a stack of layers: Hardware resources at the bottom, followed by Host OS, Hypervisor or Container Engine, and three VM(s)/Container(s) layers above. The VM layers are labeled Near RT RIC, O-CU, and O-DU. A red arrow labeled '1' points from an attacker icon to the O-DU layer. A red arrow labeled '2' points from the O-DU layer to the Hypervisor or Container Engine layer. A red arrow labeled '3' points from the Hypervisor or Container Engine layer to the Host OS layer. The Host OS layer is divided into two sections: 'Malicious VM/Container running' (red) and 'Victim VM/Container running' (black). The O-DU layer also has a red section labeled 'Victim VM/Container running'. + +Figure 7-8 : Illustration of the Theft-of-Service/DoS Attack + +| | | +|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VM-C-06 | +| Threat title | Failed or incomplete VNF/CNF termination or releasing of resources | +| Threat description |

A misconfigured VNF/CNF is instantiated in the O-Cloud infrastructure to access data not erased from a terminated VNF/CNF or any VNF/CNF that has released resources. Data could include application data, cryptographic keys, etc.

Abuse of resources allocation in the O-Cloud infrastructure to allocate to a malicious VNF/CNF the virtual resources released from a terminated VNF/CNF or from a VNF/CNF that has released resources after a move or a scaling process.

Inclusion of concealed software in the O-Cloud infrastructure to prevent the deletion/erasure of data and states of the VNF/CNF that has been terminated.

| +| Threat type | Information disclosure | +| Vulnerabilities | Lack of authentication, misconfigurations (VNF/CNF, Host OS, Hypervisor/Container Engine) | +| Impact type | Confidentiality | +| Threatened Assets | Sensitive data (e.g. passwords, private keys, subscription data, logs), VNFs/CNFs (Near RT RIC, O-CU, O-DU) software and data | +| Affected Services | No affected services | +| Potential mitigations |

REC-SNFLC Security VNF/CNF lifecycle

REC-LOG Logging, Monitoring and Alerting

REC-SS Secure Storage

REC-SCONF Security Configuration

| + +#### 7.2.4.3 Threats concerning VM/Container images + +| | | +|---------------------|-------------------------------| +| Threat ID | T-IMG-01 | +| Threat title | VM/Container images tampering | + +| | | +|------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description |

An attacker can inject malicious code or tamper the information inside the unprotected image during onboarding. Then after the instantiation of the VNF/CNF, the tampered code can cause DoS, information stealing, fraud and so on. There are several attacks categories belonging to this threat. Such attacks include:

  • • Build machine attacks: If an attacker can modify or influence the way a VM/Container image is built, they could insert malicious code that will subsequently get run in the production environment.
  • • Supply chain attacks: Once the VM/Container image is built, it gets stored in a registry, and it gets retrieved or "pulled" from the registry at the point where it's going to be run. An attacker who can replace an image or modify an image between build and deployment could run arbitrary code on your deployment.
| +| Threat type | Tampering, Information disclosure | +| Vulnerabilities | Compromised VM/Container images (Build machine attacks, Supply chain attacks) at rest, lack of authentication, misconfiguration or Insecure VM/Container images configurations | +| Impact type | Integrity, Confidentiality | +| Threatened Assets | VM/Container images | +| Affected Services | SERV#02 | +| Potential mitigations |

REC-AUD Security Audit

REC-LOG Logging, Monitoring and Alerting

REC-IMGP Image Protection

REC-VHPM Vulnerability Handling and Patch Management

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-SDLC Secure Development Lifecycle

REC-ADMC Admission Control Service

| + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-IMG-02 | +| Threat title | Insecure channels with images repository | +| Threat description |

Images often contain sensitive components like an organization's proprietary software, and embedded secrets and administrator credentials. If connections to registries are performed over insecure channels, man-in-the-middle attacks could intercept network traffic and therefore the contents integrity and confidentiality of images may be compromised. There is also an increased risk of man-in-the-middle attacks that could intercept network traffic intended for registries and steal developer or administrator credentials within that traffic. Thus, could be used to provide fraudulent or outdated images to orchestrators, etc.

| +| Threat type | Tampering, Information disclosure | +| Vulnerabilities | Compromised VM/Container images in transit | +| Impact type | Integrity, Confidentiality | +| Threatened Assets | VMs/Containers images | + +| | | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Affected Services | SERV#02 | +| Potential mitigations | REC-NS Network Segmentation & Filter Network Traffic
REC-IAM Identity, Authentication, and Access Management
REC-CM Certificate management
REC-IMGP Image Protection
REC-LOG Logging, Monitoring and Alerting | + +| | | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-IMG-03 | +| Threat title | Secrets disclosure in VM/Container images | +| Threat description |

There are scenarios which benefit from including configuration and secrets, such as passwords or credentials in VNFs/CNFs images. For e.g. VMs/Containers require to be able to connect to other VMs/Containers within the deployment as well as with external entities. All these connections need to be authenticated and secured. One way of achieving this is to provide the requisite secrets or keys to the VMs/Containers which allow them to authenticate, be authenticated, secure the communication channel and signature. A common but in-secure means of providing secrets to the VMs/Containers is by packaging the secrets or the keys with the image itself. There is the risk that the same can be extracted, read or manipulated before the VM/Container is deployed and the secret used.

With a long supply chain, VM/Container images are vulnerable to outside scrutiny. With VM/Container images containing secrets or keys, this becomes a serious threat vector. Adversaries can extract them by obtaining a copy of the image and they can be potentially shared with third parties for illicit gain.

  • • Secrets embedded within a VM/Container image can be stolen.
  • • Secrets embedded within a VM/Container image can be modified

Compromised private keys and algorithms used for image signing due to poor key protection/management/design could undermine the security of image signing process.

| +| Threat type | Spoofing, Tampering, Information disclosure | +| Vulnerabilities | Secret exposure in VNF/CNF images | +| Impact type | Authenticity, Integrity, Confidentiality | +| Threatened Assets | VM/Container images | +| Affected Services | SERV#02 | +| Potential mitigations | REC-AUD Security Audit
REC-IMGP Image Protection
REC-SS Secure Storage
REC-SDLC Secure Development Lifecycle | + +| | | +|---------------------|-------------------| +| Threat ID | T-IMG-04 | +| Threat title | Build image on VL | + +| | | +|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description |

Adversaries may build a VM/Container image directly on the VL to bypass defenses that monitor for the retrieval of malicious images from a registry.

Container example: A remote build request may be sent to the Docker API that includes a Dockerfile that pulls a vanilla base image, such as alpine, from a public or local registry and then builds a custom image upon it.

An adversary may take advantage of that build API to build a custom image on the host that includes malware downloaded from their C2 server, and they then may deploy container using that custom image. If the base image is pulled from a public registry, defenses will likely not detect the image as malicious since it's a vanilla image. If the base image already resides in a local registry, the pull may be considered even less suspicious since the image is already in the environment.

| +| Threat type | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | +| Vulnerabilities | Host misconfiguration, lack of authentication | +| Impact type | Authenticity, Integrity, Confidentiality, Availability and Authorization | +| Threatened Assets | VM/Container images | +| Affected Services | SERV#02, SERV#05 | +| Potential mitigations |

REC-AUD Security Audit

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-LOG Logging, Monitoring and Alerting

REC-IMGP Image Protection

REC-SB Secure Boot

REC-SS Secure Storage

REC-RA Remote Attestation

| + +#### 7.2.4.4 Threats concerning the virtualization layer (Host OS-Hypervisor/Container engine) + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VL-01 | +| Threat title | VM/Container hyperjacking attack | +| Threat description |

VMs/Containers run on host machines, and it is needed to ensure that those hosts (Hypervisor/Container Engine/Host OS- are not running vulnerable code (for example, old versions of components with known vulnerabilities).

Hyperjacking is an attack in which adversaries gain control over the host of a server or install a malicious Hypervisor/Container Engine/Host OS and exploit that to run malicious applications on the VM/Container that run on top of the host. This would enable the attacker to control all the VMs/Containers running on the host.

Hyperjacking involves installing a malicious, fake the Hypervisor/Container Engine/Host OS that can manage the entire server system. If the attacker gains access to the Hypervisor/Container Engine/Host OS, everything that is connected to that server can be manipulated. The Hypervisor/Container Engine/Host OS represents a single point of failure when it comes to the security and protection of sensitive information.

| + +| | | +|------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |

For a hyperjacking attack to succeed, an attacker would have to take control of the Hypervisor/Container Engine/Host OS by the following methods:

  • Injecting a rogue Hypervisor/Container Engine or Host OS beneath the original hypervisor or on top of an existing Hypervisor/Container Engine/Host OS
  • Directly obtaining control of the original Hypervisor/Container Engine or Host OS
  • Running a rogue hypervisor on top of an existing hypervisor
| +| Threat type | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | +| Vulnerabilities | Host misconfiguration, lack of authentication | +| Impact type | Authenticity, Integrity, Confidentiality, Availability and Authorization | +| Threatened Assets | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | SERV#01, SERV#03, SERV#04, SERV#05, SERV#06, SERV#07 | +| Potential mitigations |

REC-SCONF Security Configuration

REC-SB Secure Boot

REC-VHPM Vulnerability Handling and Patch Management

REC-NS Network Segmentation & Filter Network Traffic

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-ISO Strong Isolation

REC-SS Secure Storage

| + +![Figure 7-9: Illustration of the VM/Container hyperjacking attack. The diagram shows a stack of layers: Hardware resources at the bottom, followed by a layer with 'Rogue Host OS' and 'Rogue Hypervisor or Container Engine'. Above this is a layer with 'Hypervisor or Container Engine' and 'Rogue Host OS'. At the top are three boxes labeled 'VM (s)/Container(s)' containing 'Near RT RIC', 'O-CU', and 'O-DU'. An attacker icon on the left points to the 'Rogue Hypervisor or Container Engine' box (labeled 1). A dashed arrow points from the 'Rogue Hypervisor or Container Engine' box to the 'O-CU' box (labeled 2).](62c919d77bbd7e96d4804f1fa0c7a34c_img.jpg) + +Figure 7-9: Illustration of the VM/Container hyperjacking attack. The diagram shows a stack of layers: Hardware resources at the bottom, followed by a layer with 'Rogue Host OS' and 'Rogue Hypervisor or Container Engine'. Above this is a layer with 'Hypervisor or Container Engine' and 'Rogue Host OS'. At the top are three boxes labeled 'VM (s)/Container(s)' containing 'Near RT RIC', 'O-CU', and 'O-DU'. An attacker icon on the left points to the 'Rogue Hypervisor or Container Engine' box (labeled 1). A dashed arrow points from the 'Rogue Hypervisor or Container Engine' box to the 'O-CU' box (labeled 2). + +Figure 7-9 : Illustration of the VM/Container hyperjacking attack + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VL-02 | +| Threat title | Boot tampering | +| Threat description |

The bootloader of the virtualization layer (Host OS, Hypervisor, Container Engine) for VNF/CNF may be maliciously tampered by an attacker, e.g. the attacker compromises hypervisor or host OS to tamper the bootloader of guest OS (in case of VM) or Container.

In a O-Cloud environment any failure during the boot sequence can result in a number of situations that need to be handled by the NFO/FOCOM:

| + +| | | +|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |
  • • failure of the physical machine to start at all
  • • physical machine entering a safe-mode
  • • physical machine continuing boot regardless of the integrity measurements
| +| Threat type | Tampering | +| Vulnerabilities | Host misconfigurations, lack of authentication | +| Impact type | Integrity | +| Threatened Assets | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | SERV#01, SERV#03, SERV#04, SERV#05, SERV#06, SERV#07 | +| Potential mitigations | REC-SB Secure Boot
REC-PHY Physical Security Protection
REC-RA Remote Attestation
REC-LOG Logging, Monitoring and Alerting | + +| | | +|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VL-03 | +| Threat title | Attack internal network services | +| Threat description | In addition to attacking the network between containers, adversaries can also attack supporting services such as Kubernetes DNS service, which is only reachable from within the cluster network. The highly distributed nature of containers requires shared services for example for coordination and service discovery. An attacker can target these services to degrade services. For example, a denial-of-service against the service discovery infrastructure could prevent O-Cloud to react to changing resource requirements properly. Thus, O-Cloud may no longer be able to scale appropriately to sudden demand spikes [i.37]. | +| Threat type | Denial of Service | +| Vulnerabilities | Lack of authentication, vulnerable code exploits, design weakness, misconfiguration | +| Impact type | Availability | +| Threatened Assets | Software components at runtime and their associated data | +| Affected Services | SERV#03, SERV#04, SERV#05, SERV#06, SERV#07 | +| Potential mitigations | REC-ISO Strong Isolation
REC-NS Network Segmentation & Filter Network Traffic
REC-IAM Identity, Authentication and Access Management
REC-ADMC Admission Control Service | + +#### 7.2.4.5 Threats concerning O-Cloud interfaces + +##### 7.2.4.5.1 O2 interface + +Two main interfaces are defined in O-RAN WG6 specification and identified as critical assets of O-Cloud, i.e. interfaces O2 between O-Cloud and SMO. The threats on these interfaces are as follows. + +| | | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O2-01 | +| Threat title | MitM attacks on O2 interface between O-Cloud and SMO | +| Threat description |

If the interface O2 interface is not protected, an attacker can attack all the requests/responses sent between the O-Cloud and the SMO (FOCOM and NFO).

For example, the attacker can tamper/alter/disclose requests and services (See ‘Critical services’ in 2.3) sent over O2 between O-Cloud and SMO, hence the virtualized resource or relevant status information is not as requested. This affects the normal operation of the O-Cloud, and even causes DoS attacks, information leakage.

An attacker can tamper the specific assignment of virtualized resources to cause resource assignment errors or an attacker can intercept virtualized resources state information leading to information disclosure.

An attacker can compromise IMS to tamper with the hardware state information (e.g. deleting hardware alarm information) to affect the hardware's operation or to result in information disclosure (e.g. an attacker can get the hardware configuration from the compromised IMS. Then, the attacker can attack the hardware according to the configuration such as CPU type, memory size etc.). An attacker can also tamper or intercept the hardware resource configuration and state information if the configuration and state information are transmitted using an insecure protocol on the O2 interface.

| +| Threat type | Tampering, Information disclosure, Denial of Service | +| Vulnerabilities | Insecure O2 interface, lack authentication | +| Impact type | Integrity, Confidentiality, Availability | +| Threatened Assets | Telemetry, provisioning, logs, software management, performance information | +| Affected Services | SERV#01 | +| Potential mitigations |

REC-NS Network Segmentation & Filter Network Traffic

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-SCONF Security Configuration

| + +##### 7.2.4.5.2 O-Cloud API + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OCAPI-01 | +| Threat title | MitM attacks on O-Cloud interface between VNFs/CNFs and the virtualization layer | +| Threat description | An attacker can attack an instantiated VNF/CNF through a compromised virtualization layer. For example, cryptographic keys or other security critical data of an instantiated VNF/CNF could be stolen by an attacker with access to the virtualization layer, or the virtualized resource provided by the Virtualization layer to the instantiated VNF/CNF can be manipulated or the | + +| | | +|------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | bootloader of Guest OS (in case of VM) or Container of an instantiated VNF/CNF can be tampered by an attacker via a compromised virtualization layer. | +| Threat type | Tampering, Information disclosure, Denial of Service | +| Vulnerabilities | Insecure O-Cloud APIs, lack of authentication | +| Impact type | Integrity, Confidentiality, Availability | +| Threatened Assets | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | +| Affected Services | SERV#01, SERV#03, SERV#04, SERV#05, SERV#06, SERV#07 | +| Potential mitigations |

REC-NS Network Segmentation & Filter Network Traffic

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-SCONF Security Configuration

REC-SS Secure Storage

REC-PHY Physical Security Protection

| + +#### 7.2.4.6 Threats concerning hardware resources + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-HW-01 | +| Threat title | Cross VM/Container side channel attacks | +| Threat description |

In a typical cross-VM/Container side channel attack scenario, an adversary places a malicious VM/Container co-resident to the target VM/Container so that they share the same hardware resources. Then, the attacker extracts useful information such as cryptographic keys from the target VM/Container to use them for traffic eavesdropping and man-in-the-middle attacks. Through the side channel attack, an attacker sharing the same cache as the victim can monitor the cache access behavior of the victim. For example, the attacker is able to monitor cache timing information by measuring the execution of different operations on the victim's VM/Container. Generally, the attacker exploits timings in the shared high-level cache memory. However, power consumption or electromagnetic leaks can also be used as a vector to launch side channel attacks.

In the virtual environment, prior to the cross-VM/Container side channel attack, the attacker needs to identify the target VM/Container's location and place a malicious VM/Container co-resident with the target. Later, that attacker may use the maliciously placed VM/Container to extract information from the target VM/Container with the side channel attack.

Hardware vulnerabilities in processors can also have a large impact on O-Cloud security. Flaws in chip design can result in the compromise of tenant information in the cloud through side-channel attacks4.

| +| Threat type | Tampering, Information disclosure, Denial of Service | +| Vulnerabilities | Flaws in chip design, use of shared hardware, Lack of isolation, lack of authentication | +| Impact type | Integrity, Confidentiality, Availability | + +4 Graz University of Technology (2018), Meltdown and Specter. [Online] Available at: + +| | | +|------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threatened Assets | Sensitive data (e.g. passwords, private keys, subscription data, logs), VNFs/CNFs (Near RT RIC, O-CU, O-DU) related data | +| Affected Services | SERV#01, SERV#03, SERV#04, SERV#05, SERV#06, SERV#07 | +| Potential mitigations |

REC-ISO Strong Isolation

REC-PHY Physical Security Protection

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-SS Secure Storage

| + +![Figure 7-10: Illustration of a cross VM/Container side channel attack. The diagram shows a stack of layers: VM(s)/Container(s) at the top, followed by Near RT RIC, O-CU, and O-DU. Below these is the Hypervisor or Container Engine, then the Host OS, and finally the Hardware resources. A red arrow labeled '1' points from an attacker icon to the VM(s)/Container(s) layer. A red arrow labeled '2' points from the VM(s)/Container(s) layer down to the Shared cache in the Hardware resources layer, which is also marked with a bug icon.](8a1d72a3bca908ddaf09dc58d126457e_img.jpg) + +Figure 7-10: Illustration of a cross VM/Container side channel attack. The diagram shows a stack of layers: VM(s)/Container(s) at the top, followed by Near RT RIC, O-CU, and O-DU. Below these is the Hypervisor or Container Engine, then the Host OS, and finally the Hardware resources. A red arrow labeled '1' points from an attacker icon to the VM(s)/Container(s) layer. A red arrow labeled '2' points from the VM(s)/Container(s) layer down to the Shared cache in the Hardware resources layer, which is also marked with a bug icon. + +**Figure 7-10 : Illustration of a cross VM/Container side channel attack** + +| | | +|------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-HW-02 | +| Threat title | MitM attacks on the interface between virtualization layer and hardware | +| Threat description | An attacker can utilize the vulnerabilities of hardware (e.g. Meltdown and Specter of CPU in host) to attack virtualization layer and/or VNFs/CNFs through this interface, resulting in tampering, information disclosure or DoS. | +| Threat type | Tampering, Information disclosure, Denial of Service | +| Vulnerabilities | Insecure interfaces between HW and VL layers, lack of authentication, misconfiguration | +| Impact type | Integrity, Confidentiality, Availability | +| Threatened Assets | All assets | +| Affected Services | All services | +| Potential mitigations |

REC-PHY Physical Security Protection

REC-NS Network Segmentation & Filter Network Traffic

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

| + +#### 7.2.4.7 Threats concerning O-Cloud management (SMO, NFO, FOCOM) + +| | | +|------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ADMIN-01 | +| Threat title | Denial of service against NFO/FOCOM | +| Threat description |

A denial-of-service attack against the NFO/FOCOM can interfere with the ability of operators to control and maintain their deployments. This can lead to the inability to react to changing resource requirements. In addition, the NFO/FOCOM is the external API to interact with the O-Cloud platform. Thus, other services may become inaccessible as well. For example, operators may be unable to retrieve logs, telemetry data. An attacker could use this opportunity to hide additional attacks on VM/Container instances.

In addition, an attacker on the NFO/FOCOM could prevent the O-Cloud software update to exploit a known security flaw in the O-Cloud software.

| +| Threat type | Denial of Service | +| Vulnerabilities | Lack of authentication, vulnerable code exploits, design weakness, insecure O2 interface | +| Impact type | Availability | +| Threatened Assets | VM/Container images, VNF/CNF, host OS, Hypervisor/Container Engine software | +| Affected Services | SERV#02, SERV#05 | +| Potential mitigations |

REC-IAM Identity, Authentication and Access Management

REC-CM Certificate management

REC-AUD Security Audit

REC-SCONF Security Configuration

| + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ADMIN-02 | +| Threat title | Abuse an O-Cloud administration service | +| Threat description |

Usually, the SMO including NFO/FOCOM is exposed to the tenant in a web front-end or REST API. In case these interfaces contain software vulnerabilities or implement authentication and authorization insufficiently, an adversary would be able to gain access to the VM/Container management and pose as a tenant. It is also possible that an adversary gains the ability to submit requests without prior authentication and authorization.

The NFO/FOCOM interfaces encompass a great deal of privileges because anyone gaining sufficient access is able to deploy new instances and disrupt existing O-Cloud services. It may also be possible for an adversary to submit compromised VM/Container images that unsuspecting tenants then use to initiate O-Cloud services. Moreover, adversaries can use the same access to extract business data, configuration data, user data and possibly credentials. For example, they may be able to create backups of VM/Container instances or they can export VM/Container images. The impact of compromised credentials is exacerbated by the fact that weak and insufficient safeguarding of credentials is recognized as one of the top threats in cloud computing [i.38].

Container example: Adversaries may abuse a container administration service to execute commands within a container. A container administration service such as the Docker daemon, the Kubernetes API server, or the kubelet may allow remote management of containers within an environment.

| + +| | | +|------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Container example: In Docker, adversaries may specify an endpoint during container deployment that executes a script or command, or they may use a command such as docker exec to execute a command within a running container. In Kubernetes, if an adversary has sufficient permissions, they may gain remote execution in a container in the cluster via interaction with the Kubernetes API server, the kubelet, or by running a command such as kubectl exec . | +| Threat type | Tampering, Information disclosure, Denial of Service and Elevation of privilege | +| Vulnerabilities | Lack of authentication, secret exposure (insufficient safeguarding of credentials), vulnerable code exploits, design weakness | +| Impact type | Integrity, Confidentiality, Availability, Authorization | +| Threatened Assets | VNF/CNF, host OS, Hypervisor/Container Engine software and related information | +| Affected Services | SERV#03, SERV#04, SERV#06, SERV#07 | +| Potential mitigations |

REC-NS Network Segmentation & Filter Network Traffic

REC-IAM Identity, Authentication, and Access Management

REC-CM Certificate management

REC-AUD Security Audit

REC-SCONF Security Configuration

REC-VHPM Vulnerability Handling and Patch Management

| + +#### 7.2.4.8 Threats concerning Acceleration Abstraction Layer (AAL) + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-01 | +| Threat title | Attacker exploits insecure API to gain access to hardware accelerator resources | +| Threat description |

Insecure AAL API allows an attacker to tamper the requests/responses sent between the AAL components, the O-Cloud platform and O-RAN APPs/VNFs/CNFs.

For example, the attacker can tamper requests and services sent over AALI-C-Mgmt between IMS and the hardware accelerator manager, hence capability of the hardware accelerator device, fault information, logs, performance information and others are not as requested. This affects the normal operation of the O-Cloud, and even causes tampering.

An attacker can tamper application (e.g. O-DU) requests sent over AALI-C-App to an AAL implementation for allocation of buffers. This affects the normal operation of the applications, and even causes tampering.

An attacker can tamper with application (e.g. O-DU) requests sent over AALI-P for configuring and managing the AAL-LPU(s). This affects the normal operation of the applications, and even causes tampering.

| +| Threat type | Tampering | +| Vulnerabilities | Insecure AAL APIs and interfaces, lack of authentication and authorization | +| Impact type | Integrity | +| Threatened Assets | Data in transit AALI-C-App & AALI-P interfaces, Data in transit vendor specific interface, AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | +| Affected Services | SERV#03, SERV#04, SERV#06, SERV#07 | + +| | | +|------------------------------|----------------------------------------------------------------------------------------------------| +| Potential mitigations | REC-IAM Identity, Authentication and Access Management
REC-LOG Logging, Monitoring and Alerting | +|------------------------------|----------------------------------------------------------------------------------------------------| + +| | | +|------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-02 | +| Threat title | Internal Overload DoS attack targeting AAL services | +| Threat description |

Overload situation could appear in the case of DoS attack or increased traffic on AAL interfaces. Inability to mitigate traffic volumetric attacks on AAL affects availability of AAL data and services.

DoS attacks on the AALI-C interface affect the different services provided by the hardware accelerator manager and the transport abstraction framework.

DoS attacks on the AALI-P interface affect the configuration and management of AAL-LPU (Acceleration Abstraction Layer Logical Processing Unit) by an application (e.g. O-DU) in addition to acceleration functionality.

| +| Threat type | Denial of Service | +| Vulnerabilities | Insecure AAL APIs and interfaces, lack of authentication and authorization | +| Impact type | Availability | +| Threatened Assets | AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | +| Affected Services | SERV#03, SERV#04, SERV#06, SERV#07 | +| Potential mitigations | REC-IAM Identity, Authentication and Access Management
REC-LOG Logging, Monitoring and Alerting | + +| | | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-03 | +| Threat title | Fail to clear resources | +| Threat description |

Failure to clear accelerator resources after a process termination can cause an information leakage and incorrect results for computations. Further, failure to release accelerator resources may prevent other processes from running.

This threat is relevant to accelerator resources either inside the hardware accelerator device (internal memories, registers, cache) or in the O-Cloud memories used by accelerators.

| +| Threat type | Information disclosure, Denial of service | +| Vulnerabilities | Lack of secure deletion of data after process termination, Insecure AAL APIs, Flaws in AAL design | +| Impact type | Confidentiality, Availability | +| Threatened Assets | AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | +| Affected Services | SERV#03, SERV#06, SERV#07 | +| Potential mitigations | REC-LOG, REC-SS, REC-PHY, REC-SDD | + +| | | +|------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-04 | +| Threat title | HAM compromise | +| Threat description | A malicious actor can gain access to HAM to gain unauthorized access and control of the hardware accelerator device. This can result in the disruption of services (DoS) and tampering of accelerator components, such as firmware, drivers which can cause the accelerator to behave abnormally or crash altogether. | +| Threat type | Tampering, Denial of service | +| Vulnerabilities | Lack of access control, Insecure HAM APIs, Flaws in HAM design | +| Impact type | Integrity, Availability | +| Threatened Assets | Data in transit AALI-C-App & AALI-P interfaces, Data in transit vendor specific interface, AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | +| Affected Services | SERV#03, SERV#06, SERV#07 | +| Potential mitigations | REC-LOG, REC-SS, REC-PHY, REC-SDD | + +| | | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-05 | +| Threat title | Malicious memory accesses | +| Threat description |

AAL that allows one process running on the hardware accelerator device to access memory owned by another process running on the hardware accelerator device can leak information (impact on confidentiality).

Similarly, AAL allowing concurrently executing processes to write to one another's memory may have correctness errors (impact on integrity).

If multiple processes are running concurrently and one is allowed to dominate accelerator resources, the other may suffer from degraded performance. For example, if one process can evict all cache entries belonging to the other, the victim will suffer performance penalties (impact on availability).

| +| Threat type | Information disclosure, Tampering, Denial of service | +| Vulnerabilities | Unrestricted memory access, Lack of access control, Insecure AAL APIs, Flaws in AAL design | +| Impact type | Confidentiality, Integrity, Availability | +| Threatened Assets | AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | +| Affected Services | SERV#03, SERV#06, SERV#07 | +| Potential mitigations | REC-LOG, REC-SS, REC-PHY, REC-SDD, REC-ISO | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-06 | +| Threat title | Firmware attacks | +| Threat description | Hardware accelerators often have their own firmware, which can be targeted by attackers. This could include modifying the firmware to introduce vulnerabilities (e.g., malware) or installing | + +| | | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------| +| | malicious firmware to extract/modify sensitive information or execute unauthorized actions (e.g., control the device remotely). | +| Threat type | Information disclosure, Tampering | +| Vulnerabilities | Weak accelerator design, Misconfiguration, Insecure AAL/HAM APIs | +| Impact type | Confidentiality, Integrity | +| Threatened Assets | AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | +| Affected Services | SERV#03, SERV#06, SERV#07 | +| Potential mitigations | REC-LOG, REC-SS, REC-PHY, REC-SDD, REC-ISO | + +#### 7.2.4.9 Threats concerning O-Cloud instance ID + +| | | +|------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-CLOUD-ID-01 | +| Threat title | ID reuse in O-Cloud's object lifecycle | +| Threat description |

In O-Cloud, objects such as Containers, Pods, Nodes, and Services are identified by their IDs within a given compute pool (e.g., cluster in Kubernetes). When an object is deleted, its ID becomes available for reuse. This means that a new object can be created with the same ID as a previously deleted object. If an object gets deleted but all its associated data isn't properly isolated or cleaned, the ID, if reused, could lead to unintended data associations or leaks.

Potential consequences:

  • • Data Residue: A new object, reusing an ID, may inherit residual data or configurations from its predecessor, leading to potential misconfigurations and incorrect data associations. This can result in sensitive data exposure.
  • • Data Overwrite: Automated processes unaware of the deletion and subsequent recreation might mistakenly write or read data from the new object, thinking it's the old one.
  • • Monitoring Ambiguities: Monitoring tools might combine metrics from the old and new objects, resulting in confusing data.
  • • Operational Disruptions: The new object might operate based on the residual configurations of the old object, potentially leading to system inefficiencies or failures.
| +| Threat type | Tampering, Information disclosure | +| Vulnerabilities | Predictable ID generation, Insufficient logging or auditing, Insufficient ID validation | +| Impact type | Integrity, Confidentiality | +| Threatened Assets | O-Cloud Provisioning information, Software components at runtime and their associated data, Security event logs | +| Affected Services | SERV#04, SERV#05 | +| Potential mitigations | REC-IDM O-Cloud ID secure management | + +| | | +|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-CLOUD-ID-02 | +| Threat title | Node redundancy in O-Cloud deployments | +| Threat description |

Nodes in O-Cloud often represent physical or virtual machines. If a machine fails and is replaced without deleting its corresponding Node object, and the new machine is given the same ID or the hostname, O-Cloud might treat the new machine as if it were the original.

Potential consequences:

  • • Resource Mismatch: The new host might have different resources (CPU, memory, storage) than the old one, leading to scheduling issues or resource constraints.
  • • Stale Data: The new node might inherit data or configurations from the old node, leading to potential security or operational risks.
  • • Network Issues: Network configurations or IP address assignments might be inconsistent or conflicting.
| +| Threat type | Spoofing, Tampering, Information disclosure, Denial of Service | +| Vulnerabilities | Lack of node validation, Inadequate resource allocation and monitoring, Lack of network configuration verification | +| Impact type | Authenticity, Integrity, Confidentiality, Availability | +| Threatened Assets | O-Cloud Provisioning information, Software components at runtime and their associated data, Security event logs | +| Affected Services | SERV#04, SERV#05 | +| Potential mitigations | REC-IDM O-Cloud ID secure management | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-CLOUD-ID-03 | +| Threat title | O-Cloud ID mismanagement | +| Threat description |

IDs are crucial for uniquely identifying objects within the O-Cloud. Mismanagement occurs when these IDs are not properly assigned, tracked, or validated, leading to potential overlaps or inconsistencies.

Potential consequences:

  • • ID Collision: Due to system glitches or bugs, two distinct objects could inadvertently be allocated the same ID. Such an occurrence is termed an ID collision. This can result in operations meant for one object inadvertently affecting the other.
  • • Resource Overwrite: If two objects share the same ID, updates or modifications intended for one might overwrite the data of the other, leading to data inconsistencies or loss.
  • • ID-Based Permissions: Many security protocols and access controls in O-Cloud can be tied to object IDs. If an attacker can predict, guess, or manipulate the ID generation process, they might gain unauthorized access to resources.
  • • Log Merging: Monitoring tools and logging systems use IDs to track events and operations related to specific objects. If two objects share an ID, their logs might get merged, making it challenging to trace events back to their source.
| + +| | | +|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |
  • RBAC Anomalies: Role-Based Access Control (RBAC) regulations attached to specific object IDs could unintentionally approve or restrict access to the novel object due to misidentification.
| +| Threat type | Spoofing, Tampering, Information Disclosure, Repudiation, Elevation of Privilege, Denial of Service | +| Vulnerabilities | Inefficient ID assignment algorithm, Lack of validation checks during the ID assignment or object creation process, Weak or absent monitoring of ID lifecycle, Insufficient randomization in ID generation, Lack of timely updates to RBAC policies, Lack of ID collision detection | +| Impact type | Authenticity, Integrity, Non-repudiability, Confidentiality, Availability, Authorization | +| Threatened Assets | O-Cloud Provisioning information, Software components at runtime and their associated data, Security event logs | +| Affected Services | SERV#04, SERV#05 | +| Potential mitigations | REC-IDM O-Cloud ID secure management | + +#### 7.2.4.10 Threats concerning time synchronization + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-TS-01 | +| Threat title | Time synchronization disruption in O-Cloud | +| Threat description |

Disruption or manipulation of the time synchronization process within the O-Cloud can lead to severe security and operational issues. An attacker may target the time synchronization mechanisms to alter time settings across O-Cloud nodes, leading to:

  • Impersonation of time synchronization server: An attacker may impersonate a legitimate time synchronization server, tricking nodes into accepting incorrect time data. This can cause nodes to synchronize with a malicious time source, leading to widespread time discrepancies.
  • Data integrity loss: Inconsistent timestamps can corrupt logs and audit trails within the O-Cloud, making it difficult to trace and analyze security events accurately.
  • Operational disruption: Time-sensitive operations within the O-Cloud may be disrupted, leading to data loss and service outages.
  • Authentication and authorization bypass: Many security mechanisms in the O-Cloud rely on accurate time. Disrupted time synchronization can undermine token expiration, certificate validity, and other time-based access controls, potentially allowing unauthorized access to O-Cloud resources.

EXAMPLE: Time-sensitive operations such as automated backups, scheduled tasks (e.g., resource scaling, patch management), and certificate renewals.

NOTE: This threat is linked to the operation of CronJob resources as described in clause 4.3.1.1.6 of the O-RAN specification [1.65]. Any disruption or manipulation of the time synchronization process can severely impact scheduled operations managed by CronJobs within the O-Cloud.

| +| Threat type | Spoofing, Tampering, Denial of Service and Elevation of privilege | +| Vulnerabilities | Insecure time synchronization protocols | + +| | | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Insufficient authentication mechanisms and access controls for the time synchronization settings
Misconfiguration of time synchronization settings on O-Cloud nodes | +| Impact type | Authenticity, Integrity, Availability and Authorization | +| Threatened Assets | Log and audit trails
O-Cloud time synchronization settings | +| Affected Services | SERV#03, SERV#06, SERV#07 | +| Potential mitigations | REC-SCONF Security Configuration
REC-IAM Identity, Authentication, and Access Management
REC-CM Certificate management
REC-LOG Logging, Monitoring, and Alerting | + +# 8 Recommendations and best practices + +A large number of useful and relevant security guidelines and best practices exist that are relevant for VM/Container-based virtualization and cloud computing in general. Therefore, we provide them here collectively and highly recommend that readers consult them for additional references: + +- 3GPP TS 33.848 Study on security impacts of virtualisation +- MITRE containers matrix +- CIS Critical Security Controls +- CIS Docker Benchmark +- CIS VMWARE Benchmark +- ONAP master documentation +- CISA/NSA Kubernetes security guidance +- OpenStack security guide +- Cloud native wiki by aqua +- ANSSI “Recommandations de sécurité relatives aux déploiements de conteneur docker “ +- CISA/NSA “Security guidance for 5g cloud infrastructures” parts 1 to 4 +- GSMA NG.126 “Cloud Infrastructure Reference Model” +- Docker best practices +- FFTelecoms “Référentiel d'objectifs de sécurité en matière de fonctions réseau virtualisées “ +- Fraunhofer AISEC Threat analysis of container-as-a-service for network function virtualization + +## 8.1 REC-CM Certificate management + +**Recommendation:** O-Cloud should support Public Key Cryptography for the purpose of distributing Public Key Certificates (PKC) for authenticating, authorizing, and encrypting links between components in O-Cloud. Each operator should develop a Certificate Policy in accordance with their regional and national requirements. In addition, Operators should setup a renewal procedure (preferably automatically) of certificates prior to their expiration. + +In O-Cloud, the following scenarios are considered for certificate usage: + +- O-Cloud and VNFs/CNFs should employ certificates which can be used for images signing and verification during onboarding and registration. +- SMO and VNF/CNF should employ certificates which can be used in order to establish secure connections between them. +- SMO employs certificates in order to establish secure management connections with NFO and FOCOM. +- O-Cloud infrastructure employs certificate(s) in order to establish secure connections with NFO and FOCOM through O2 interface. + +**Best practices to fulfill this recommendation:** + +| BP ID | Description | +|-------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-CM-BP-1 | The certificate policy should be consistent with the Internet X.509 Certificate Policy and Certification Practices Framework as defined in IETF RFC 3647 [i.9]. | +| REC-CM-BP-2 | In order to eliminate or mitigate risks against attacks such as spoofing, tampering and information disclosure, secure connection can be established on all the interfaces within O-Cloud. IPsec and TLS mechanisms are widely deployed to protect the communication between O-Cloud components using certificates. | +| REC-CM-BP-3 | Certificate management in O-Cloud should be automated and manual operations should be avoided as much as possible. Automated certificate lifecycle management should be supported, i.e. creation, update and revocation of certificate. | +| REC-CM-BP-4 | It's important to continuously monitor and audit certificates that are issued and active, with the ability to generate audits and keep on top of expirations and renewals to avoid any disruption in O-Cloud services. Unknown, rogue or non-complaint certificates can result in an unexpected outage, or worse, misuse that allows unintended access to O-Cloud components. | +| REC-CM-BP-5 | Securing the CAs that issue the certificates is critical. If a CA is compromised, attackers can issue their own identities that will be trusted by default across O-Cloud, and this can be extremely costly to remediate, as it effectively invalidates every identity issued by that CA. Hardware devices such as HSMs should be used to secure CA certificates and keys, ensure robust protection and complete visibility, policy enforcement, and automation for all certificates. | + +For more details see ETSI GR NFV-SEC 005 [i.10]. + +**This recommendation can help to mitigate:** T-GEN-02, T-GEN-04, T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-IMG-01, T-IMG-02, T-IMG-04, T-VL-01, T-O2-01, T-OCAPI-01, T-HW-01, T-HW-02, T-ADMIN-01, T-ADMIN-02, T-TS-01 + +## 8.2 REC-NS Network Segmentation & Filter Network Traffic + +**Recommendation:** Physical and logical segmentation to prevent access to potentially sensitive O-Cloud components and information should be implemented. In addition, network policies should be defined to ensure a secure communication between VMs/Containers and limit the communication between VMs/Containers as much as possible to limit potential damage if a VM/Container is compromised. + +### Best practices to fulfill this recommendation: + +| BP ID | Description | +|--------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-NS-BP-1 | Isolate O-Cloud infrastructure components that do not require broad network access. | +| REC-NS-BP-2 | Configure access controls, network proxies, gateways, and firewalls to limit access to:
  • Critical O-Cloud components. Most cloud environments support separate virtual private cloud (VPC) instances that enable further segmentation of cloud systems.
  • Systems used to create and manage accounts.
| +| REC-NS-BP-3 | Follow best practices for network firewall and proxies configurations to allow only necessary ports and legitimate traffic to enter and exit the network. | +| REC-NS-BP-4 | Operate intrusion detection, analysis, and response systems on a separate network from the production environment to lessen the chances that an adversary can see and interfere with critical response functions. | +| REC-NS-BP-5 | Consider filtering DNS requests to unknown, untrusted, or known bad domains and resources. Resolving DNS requests with on-premise/proxy servers may also disrupt adversary attempts to conceal data within DNS packets. | +| REC-NS-BP-6 | Enforce proxies and use dedicated servers for services such as DNS and only allow those systems to communicate over respective ports/protocols, instead of all systems within a network. | +| REC-NS-BP-7 | Consider using IP allowlisting along with user account management to ensure that data access is restricted not only to valid users but only from expected IP ranges to mitigate the use of stolen credentials to access data. | +| REC-NS-BP-8 | Apply extended ACLs to block unauthorized protocols outside the trusted network. | +| REC-NS-BP-9 | Upon identifying a compromised network device being used to bridge a network boundary, block the malicious packets using an unaffected network device in path, such as a firewall or a router that has not been compromised. Continue to monitor for additional activity and to ensure that the blocks are indeed effective. | +| REC-NS-BP-10 | When flood volumes exceed the capacity of the network connection being targeted, it is typically necessary to intercept the incoming traffic upstream to filter out the attack traffic from the legitimate traffic. Such defenses can be provided by the hosting Internet Service Provider (ISP) or by a 3rd party such as a Content Delivery Network (CDN) or providers specializing in DoS mitigations. | +| REC-NS-BP-11 | Filter network traffic to prevent use of protocols across the network boundary that are unnecessary. | +| REC-NS-BP-12 | Use of network intrusion detection and prevention systems that can
  • Identify traffic patterns and use network signatures to identify traffic for specific adversary malware, can be used to mitigate malicious activity at the network level.
  • Detect and prevent remote service scans.
| + +**This recommendation can help to mitigate:** T-GEN-02, T-GEN-06, T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-IMG-02, T-VL-01, T-O2-01, T-OCAPI-01, T-HW-02, T-ADMIN-02 + +## 8.3 REC-IAM Identity, Authentication and Access Management + +**Recommendation:** A strong IAM framework should be in place to ensure authentication, authorization, accounting and access control. It should be used to initiate, capture, record and manage user identities and their related access permissions to O-Cloud assets in an automated way. + +The IAM framework should be set up to manage and secure access to NFO/FOCOM, VNFs/CNFs, Host OS, Hypervisor, Container Engine, data and services that reside in the O-Cloud. This framework should protect credentials and accounts associated with O-Cloud platforms. Specifically, IAM protects root accounts for servers in the O-Cloud, limits privileged access to the O-Cloud control panel and governs ongoing access to privileged resources in the O-Cloud. + +IAM should be based on Authentication, Authorization, and Accounting (AAA) systems and least privileges approach to limit actions administrators can perform and provide a history of user actions to detect unauthorized use and abuse. + +Protocols without encryption/authentication mechanisms should not be used. Access to administrative and management interfaces from untrusted network sources should be limited. + +### Best practices to fulfill this recommendation: + +| Req ID | Description | +|--------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-IAM-BP-1 |

OAuth2.0 with access token defined by IETF RFC 6749 [i.11] should be used for the authorization of API request and notifications. There are several existing Access Token solutions. Such solutions are Openstack Keystone5, OpenID Connect6, 3GPP authorization framework ETSI TS 133 5017, IETF TLS-Based AccessToken Binding8 9.

For more details see ETSI GR NFV-SEC 022 [i.12].

| +| REC-IAM-BP-2 | O-Cloud components must support authenticated and secure access to API, GUI and command line interfaces. In addition, they must support Traffic Filtering (for example, FireWall, IDS/IPS). | +| REC-IAM-BP-3 | O-Cloud interfaces should support secure and encrypted communications, and confidentiality and integrity of network traffic on all channels. All APIs access must use TLS protocol, including back-end APIs [i.45]. | +| REC-IAM-BP-4 |

O-Cloud components should implement controls enforcing separation of duties and privileges, least privilege use and least common mechanism (e.g. Role-Based Access Control).

Communication between different trust domains is not allowed, by default.

The O-Cloud infrastructure must not allow the effect of an attack on one trust domain to impact the other domains either directly or indirectly.

| +| REC-IAM-BP-5 |

The O-Cloud should not reuse the same authentication credential (e.g., key-pair) on different components (e.g., on different hosts, or different services).

The O-Cloud should protect all secrets by using strong encryption techniques and storing the protected secrets externally from the component.

The O-Cloud should provide secrets dynamically as and when needed.

| + +5 + +6 [https://openid.net/specs/openid-connect-core-1\\_0.html](https://openid.net/specs/openid-connect-core-1_0.html) + +7 TSI TS 133 501: "5G; Security architecture and procedures for 5G System (3GPP TS 33.501)" + +8 draft-ietf-oauth-token-binding-08: "OAuth 2.0 Token Binding", Work in progress + +9 IETF RFC 8705: "OAuth 2.0 Mutual-TLS Client Authentication and Certificate-Bound Access Tokens" + +| | | +|---------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-IAM-BP-6 | Data Centre Operations staff and O-Cloud components should use management protocols that limit security risk. Management protocols such as SNMPv3, SSH v2, ICMP, NTP, syslog, and TLS v1.2 or higher. | +| REC-IAM-BP-7 | Remotely available services that may be unnecessary should be disabled or blocked. Remote access to internal O-Cloud resources should be controlled using centrally managed concentrators such as VPNs and other managed remote access systems of network, proxies, gateways, and firewalls.

Strong two-factor or multi-factor authentication for remote service accounts to mitigate an adversary's ability to leverage stolen credentials should be used. | +| REC-IAM-BP-8 | Ensure VM/Containers are not running as root by default. | +| REC-IAM-BP-9 | Do not allow domain administrator accounts (of Active directory) to be used for day-to-day operations that may expose them to potential adversaries on unprivileged systems.

Consider using temporary credentials for accounts that are only valid for a certain period of time to reduce the effectiveness of compromised accounts. | +| REC-IAM-BP-10 | Limit access to the root account and prevent users from loading kernel modules and extensions through proper privilege separation and limiting Privilege Escalation opportunities. | +| REC-IAM-BP-11 | Container: Run the microservice with the least privilege possible; First, never use the --privileged flag. It gives all so-called capabilities to the container, and it can access host devices (/dev) including disks, and also has access to the /sys and /proc filesystem. And with a little work the container can even load kernel modules on the host 10 . The good thing is that containers are per default unprivileged. You would have to configure them explicitly to run privileged. | +| REC-IAM-BP-12 | When Administrative Shell is necessary, restrict Administrative Shell execution policy to administrators. Be aware that there are methods of bypassing the Administrative Shell execution policy, depending on environment configuration. | +| REC-IAM-BP-13 | Least privilege principles:
  • • Use the principal of least privilege and protect administrative access to domain trusts such as the service account in Kubernetes, Openstacks, etc. to limit impact of exploitation.
  • • Restrict administrator accounts to as few individuals as possible, following least privilege principles.
  • • Limit permissions associated with creating and modifying images or VMs/Containers based on the principle of least privilege.
| +| REC-IAM-BP-14 | Prevent credential overlap across systems of administrator and privileged accounts. | +| REC-IAM-BP-15 | Ensure critical system files as well as those known to be abused by adversaries have restrictive permissions and are owned by an appropriately privileged account, especially if access is not required by users nor will inhibit system functionality. | +| REC-IAM-BP-16 | Audit domain and local accounts as well as their permission levels routinely to look for situations that could allow an adversary to gain wide access by obtaining credentials of a privileged account. These audits should also include if default accounts have been enabled, or if new local accounts are created that have not been authorized. | +| REC-IAM-BP-17 | Do not put user or admin domain accounts in the local administrator groups across systems unless they are tightly controlled, as this is often equivalent to having a local administrator account with the same password on all systems. | + +10 + +| | | +|---------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-IAM-BP-18 | Do not allow remote access to services as a privileged account unless necessary. | +| REC-IAM-BP-19 | Do not allow remote access via SSH as root or other privileged accounts. | +| REC-IAM-BP-20 | Restrict execution of particularly vulnerable binaries to privileged accounts or groups that need to use it to lessen the opportunities for malicious usage. | +| REC-IAM-BP-21 | Ensure that any accounts used by third-party providers to access these systems are traceable to the third-party and are not used throughout the network or used by other third-party providers in the same environment. Ensure there are regular reviews of accounts provisioned to these systems to verify continued business need and ensure there is governance to trace de-provisioning of access that is no longer required. Ensure proper system and access isolation for critical network systems through use of account privilege separation. | +| REC-IAM-BP-22 | A Cloud Access Security Broker (CASB) can be used to set usage policies and manage user permissions on cloud applications to prevent access to application access tokens. | +| REC-IAM-BP-23 |

Password policy

  • O-Cloud components that utilize default username and password should be changed immediately after the installation, and before deployment to a production environment. When possible, passwords should be updated periodically and properly secured. (Refer to NIST guidelines when creating password policies NIST Special Publication 800-63B11, CIS Password Policy Guide12).
  • Use strong passwords to increase the difficulty of credential hashes from being cracked if they are obtained.
  • Do not reuse local administrator account passwords across systems. Ensure password complexity and uniqueness such that the passwords cannot be cracked or guessed.
  • In case SSH is used with password (not recommended), Ensure SSH key pairs have strong passwords and refrain from using key-store technologies such as ssh-agent unless they are properly protected.
  • Consider rotating access keys within a certain number of days to reduce the effectiveness of stolen credentials.
  • Use strong passphrases for private keys to make cracking difficult. Do not store credentials within the Registry. Establish an organizational policy that prohibits password storage in files.
  • Ensure that cloud accounts, particularly privileged accounts, have complex, unique passwords across all systems on the network. Passwords and access keys should be rotated regularly. This limits the amount of time credentials can be used to access resources if a credential is compromised without your knowledge. Cloud service providers may track access key age to help audit and identify keys that may need to be rotated.
| + +**This recommendation can help to mitigate:** T-GEN-02, T-GEN-04, T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-IMG-01, T-IMG-02, T-IMG-04, T-VL-01, T-O2-01, T-OCAPI-01, T-HW-01, T-HW-02, T-ADMIN-01, T-ADMIN-02, T-TS-01 + +11 + +12 + +## 8.4 REC-VHPM Vulnerability Handling and Patch Management + +**Recommendation:** A vulnerability handling process should be in place to find potentially exploitable software vulnerabilities, to determine what types and levels of threat may use software exploits and 0-days against O-Cloud and to remediate them. + +A patch management process should be implemented to check unused dependencies, unmaintained and/or previously vulnerable dependencies, unnecessary features, components, files, and documentation. + +**Best practices to fulfill this recommendation:** + +| BP ID | Description | +|---------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-VHPM-BP-1 | Regularly scan O-Cloud software components for vulnerabilities and establish procedures to rapidly patch systems when critical vulnerabilities are discovered through scanning and through public disclosure. | +| REC-VHPM-BP-2 | Regularly scan the internal network for available services to identify new and potentially vulnerable services. | +| REC-VHPM-BP-3 | Continuous monitoring of vulnerability sources and the use of automatic and manual code review tools should also be implemented as well. | +| REC-VHPM-BP-3 |

Patch strategy shall be applied for each component to maintain the O-Cloud software.

The patch strategy should handle regular and emergency patches. It is also needed to be prepared for testing patches and rollback procedures. The patch strategy should be automated. It's also recommended to make use of plugins for monitoring software and notifying of pending patches.

Keep in mind that some patches require a restart of their service, a new deployment (VM/Container image) or even a reboot (host) to become effective. If this won't be done, patching otherwise could be as effective as just not to patch. Technical details when to restart a service, a host or initiate a new deployment need to be defined in the patch strategy too.

There are four different patch domains:

  • • Images: the VM/Container distribution
  • • Hypervisor/Container Engine software: e.g., VMware vSphere, Docker
  • • Orchestration software (Kubernetes, Mesos, OpenShift, ...)
  • • Host operating system
| +| REC-VHPM-BP-4 | Maintain SBOMs for O-RAN software components in a centralized repository. This will make possible to quickly scan and search the SBOM for any Zero-Day vulnerability when get disclosed, which allows O-Cloud operator to respond quickly to the Zero-day vulnerability to mitigate potential attacks. For more details about SBOM see Clause 4 'SBOM Guidelines for O-RAN' in [i.42]. | + +**This recommendation can help to mitigate:** T-GEN-01, T-IMG-01, T-VL-01, T-ADMIN-02, T-O2-01, T-OCAPI-01 + +## 8.5 REC-SCONF Security Configuration + +**Recommendation:** The O-Cloud virtualization layer shall + +- Be configured to ensure conformance to industry standard benchmarks and requirements with respect to security configurations. +- Use automated or manual mechanisms to detect configuration drifts/misconfigurations from industry standard benchmarks and requirements. + +### Best practices to fulfill this recommendation: + +| BP ID | Description | +|----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-SCONF-BP-1 |

O-Cloud virtualization layer should be configured to adhere/conform to industry standard benchmarks and guidelines for securing the virtualization layer. For example, the CIS benchmark guidelines enforce many security configurations related to the container deployment like:

  • • Avoid running containers as privileged, apply the principle of least privilege access controls for privileged containers, and restrict functionality of privileged containers.
  • • Restrict containers from using hostPath volume mounts write permissions from within container.
  • • Enforce non-root default user in containers (using Kubernetes pod spec parameters or USER directive in Dockerfile).
| +| REC-SCONF-BP-2 |

O-Cloud operator & vendor should perform automated or manual scans to check security posture adherence to industry standard benchmarks. For example, Cloud Security Posture Management tools can be used to check conformance to industry standard benchmarks like CIS, NIST, etc.

| +| REC-SCONF-BP-3 |

O-Cloud CNF vendors should define the CPU and Memory requirements of their CNF applications, ie, the CPU and Memory requirements for the CNF applications to perform its functions under normal operating scenarios and the threshold limit value of CPU & Memory requirements beyond which the CNF should not be allowed to use. O-Cloud virtualization platform should consider the CPU & Memory resource requirements & limits associated to each CNF provided by O-Cloud CNF vendors during onboarding of the CNFs.

| +| REC-SCONF-BP-4 |

O-Cloud virtualization platform should consider enforcing the O-Cloud CNF vendors to specify the CPU & Memory resource requirements & limits using suitable admission controller solutions. Setting CPU & memory limits will help OCloud virtualization platform to avoid a rogue CNF container using up all resources thereby starving off other co-located CNF containers.

| + +**This recommendation can help to mitigate:** T-VM-C-01, T-VM-C-02, T-VM-C-06, T-VL-01, T-ADMIN-01, T-ADMIN-02, T-TS-01 + +## 8.6 REC-SDLC Secure Development Lifecycle + +**Recommendation:** Software providers should assume that their VNFs/CNFs and VL software contain flaws and have appropriate processes in place to mitigate these cases. To this end, they should adopt a secure software development life-cycle (S-SDLC). A S-SDLC integrates security considerations into the normal software development life-cycle. This ensures that risks, threats, and security mechanisms are formalized alongside the development of VNFs/CNFs and VL. + +### Best practices to fulfill this recommendation: + +| Req ID | Description | +|---------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-SDLC-BP-1 |

Define and implement good coding practices. This includes writing documentation, adopting secure programming guidelines, enforcing code quality metrics and performing software tests. In particular, code quality and adherence to coding standards can be checked automatically with tools, such as SonarQube13. With this approach, the chance of introducing easily exploitable vulnerabilities into the code is reduced.

| + +13 + +| | | +|---------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-SDLC-BP-2 | Modern continuous integration (CI) and continuous delivery (CD) systems can be used to build new container images from code repositories, such as Git 14 automatically. Thus, every commit can be used to generate a new container image that is immediately deployed for testing in a development environment. Once a new software version passes all tests, it can be deployed automatically to the O-Cloud platform. This step should be safeguarded by an internal approval process. For example, operators can configure their CI/CD pipeline to only start deployment in production after quality assurance, security testing and operations have approved the new version. | +| REC-SDLC-BP-3 | During development, developers may include private keys and configuration files with passwords into their VM/Container images for convenience and testing reasons. However, this information should never be published in a production VM/Container image. Thus, one of important step before actually deploying any VM/Container image to the O-Cloud platform is to verify that no sensitive information is included. In case of Docker, recent versions allow to specify these image differences between development and operations by using multiple FROM commands, i.e., one for development and one production in the respective Dockerfile. | +| REC-SDLC-BP-4 | Define mechanisms and processes that ensure that VM/Container image metadata is signed and verified. Thus, if operators download an image from a party they trust, they can verify the signature and the cryptographic hashes of the image files.

Example: use of Docker Notary and Content Trust 15 | + +This recommendation can help to mitigate: T-GEN-01, T-IMG-01, T-IMG-03 + +## 8.7 REC-SNFLC Security App/VNF/CNF lifecycle + +**Recommendation:** Security in the life cycle management of Apps/VNFs/CNFs should be integrated during development, onboarding, instantiation, scaling, migration, and termination. Security lifecycle management must be adapted to work in a more dynamic environment with fast-changing network topology, data flow paths, and network addresses. + +**Best practices to fulfill this recommendation:** + +| Req ID | Description | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-SNFLC-BP-1 | Before an App/VNF/CNF is deployed, the NFO/FOCOM system should verify compliance with its build-configuration standards. A check can include but is not limited to:
  • • Security of the configuration
  • • Whether the package contains only trusted and expected components
  • • Whether trusted components have been altered (integrity)
| +| REC-SNFLC-BP-2 | Apps/VNFs/CNFs can easily be cloned and instantiated. As a result, a security framework must address the following elements:
  • • Depending on the migration technique, certificates, accounts, media access control addresses, or hardware IDs will look identical after cloning.
  • • Trusted platform modules (e.g., TPM, HSM, Intel's Trusted Execution Technology, or TXT) may be required to ensure that virtual components can provide attestation or a true status of the security of the underlying hardware and physical location.
| + +14 + +15 [https://docs.docker.com/engine/security/trust/content\\_trust/](https://docs.docker.com/engine/security/trust/content_trust/) + +This recommendation can help to mitigate: T-GEN-03, T-VM-C-01, T-VM-C-02, T-VM-C-04, T-VM-C-06 + +## 8.8 REC-IMGP Image Protection + +**Recommendation:** Only images from secure and trusted sources should be used. These images should be scanned to ensure that images do not contain vulnerable software. + +The App/VNF/CNF images shall not be packaged with embedded secrets such as passwords or credentials, or any other critical configuration data. + +During the onboarding, the authenticity and integrity of the VNF Package should be verified against the signature provided by the VNF provider. Furthermore, Operators should undertake additional security validation of the VNF Package during the onboarding process and operator's signing should be used to certify the VNF as authorized to onboard into the operator's network [i.46], [i.47]. + +**Best practices to fulfill this recommendation:** + +### Image Scanning + +Scanning process needs to identify when Apps/VNFs/CNFs are running with out-of-date packages that need to be updated for security patches. Further, it should identify malware that has been built into an image. The O-Cloud VL should enforce image scans to check and flag the presence of secrets in images. + +- (1) VM/Container images need to be frequently scanned throughout the lifecycle of the App/VNF/CNF + +| During Development | Within the registry | Before Deployment | During Runtime | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +|

Perform frequent scanning for known vulnerability or misconfiguration on App/VNF/CNF image during build phase. E.g., Check for malware, secrets stored in image.

Ideal to automate with CI pipeline.

Responsible: O-RAN Solution Provider/Vendor

|

Regular scan for App/VNF/CNF image known vulnerability or misconfiguration stored in the registry. E.g., scan for new vulnerabilities after built.

Responsible: O-RAN Solution Provider/Vendor/Operator

|

Perform frequent scanning for known vulnerability or misconfiguration on App/VNF/CNF image before deployment using admission control techniques. Admission controller could block deployments if the image doesn't comply with the operator security policies e.g., To check the images used to create CNF pods are secure by checking for malware.

Ideal to automate with CD pipeline.

Responsible: O-RAN Solution Provider/Vendor/Operator

|

Perform continuous scanning/monitoring for known vulnerability or misconfiguration on runtime workloads, check for any open ports, VM/Container escape.

Responsible: Operator/O-Cloud Operator

| + +- (2) As part of O-RAN App/VNF/CNF development, O-RAN Solution Provider/Vendor is recommended to choose base images and packages used in the O-RAN App/VNF/CNF from a trusted publisher or create in-house base images. Choosing trusted signed images helps to mitigate MITM attacks that can introduce vulnerabilities into the base images available in public registries. +- (3) As part of O-RAN App/VNF/CNF development, O-RAN Solution Provider/Vendor is recommended to choose minimal base images that bundle only the necessary system tools and libraries required by O-RAN App/VNF/CNF, to limit the attack surface of O-RAN App/VNF/CNF. + +### App/VNF/CNF Image Signing + +**Responsible:** App/VNF/CNF Solution Provider/Vendor and/or Operator + +- (1) App/VNF/CNF Solution Provider creates public/private key pair for code signing. +- (2) CA verifies public key belong to the owner and issue CA certificate with attached public key. +- (3) Hash function on App/VNF/CNF Image returns image Digest. +- (4) Image Digest is encrypted with private key. +- (5) Signed App/VNF/CNF Image contains CA Certificate, Digest, Hash function. + +### *App/VNF/CNF Image Verification* + +**Responsible:** Operator or O-Cloud Operator + +- (1) Verify CA certificate for authenticity. +- (2) Decrypt digest with public key +- (3) Compare Decrypted digest with Digest computed as result of Hash function on App/VNF/CNF Image. +- (4) Verification is successful if both digest matches. + +#### *Proposed Signing/Verification Models* + +1. Software signing by Solution Provider/Vendor, Software verification at runtime by O-Cloud Operator +2. Software signing by Solution Provider/Vendor, Software verification by operator before onboarding vendor images to the operator registry +3. Software signing by Operator, Software verification at runtime by O-Cloud Operator +4. Software signing by Solution Provider/Vendor, Software verification at runtime by O-Cloud Operator and/or Operator. +5. Software signing by solution provider/vendor, Software verification by Operator and software re-signing by Operator before onboarding vendor images to the operator registry, software verification at instantiation. + +### **Other best practices:** + +- Least privilege access that limits and controls access to the images' repository and the repository of source code, secure storage, and automation for verifying the configuration of images before loading. +- Utilize a trust model such as Docker Content Trust with digital signatures to ensure runtime verification of the integrity and publisher of specific image tags. +- Implement only digitally signed host images to validate the integrity of the software used on the O-Cloud platform. Make use of this feature where possible in order to prevent and/or detect attempts by adversaries to compromise the host image. +- The registry is most sensitive part of the system and should be run in an HSM. +- The App/VNF/CNF images shall not be packaged with embedded secrets such as passwords or credentials, or any other critical configuration data. Secrets have to be stored outside the App/VNF/CNF images. For example, K8s secrets or external secrets managers (like Vault) can be used to store secret and sensitive information hence preventing the threat of packaging secrets in CNF container images. Secrets required by containerized applications can be injected into the CNF container from the External Secrets Manager as required. +- Encrypting VNF volume / swap areas: Virtual volume disks associated with VNFs may contain sensitive data. Therefore, they need to be protected. The best practice to secure the VNF volume is by encrypting them and storing the cryptographic keys at safe locations. The TPM module can also be used to securely store these keys. In + +addition, the hypervisor should be configured to securely wipe out the virtual volume disks in the event a VNF is crashed or intentionally destroyed to prevent it from unauthorized access. VM swapping is a memory management technique used to move memory segments from the main memory to disk, which is used as a secondary memory in order to increase system performance in case the system runs out of memory. These transferred memory segments can contain sensitive information such as passwords and certificates. They can be stored on the disk and remain persistent even after system reboot. This enables an attack scenario whereby a VM swap is copied and investigated to retrieve any useful information. One way to avoid this kind of attack is to encrypt VM swap areas. Linux based tools such as dm-crypt can be used for this purpose. + +**This recommendation can help to mitigate:** T-GEN-01, T-GEN-03, T-IMG-01, T-IMG-02, T-IMG-03, T-IMG-04 + +## 8.9 REC-LOG Logging, Monitoring and Alerting + +**Recommendation:** The continuous security of O-Cloud software depends on the ability to identify attacks and reconstruct them. The earlier operators identify suspicious behavior and possible attacks, the faster they can initiate countermeasures. In the best case, they are able to stop attacks before severe harm is done. In the worst case, they at least are able to reduce the attacks' severity and collect important details on the attack itself. This knowledge is important to find and fix flaws and vulnerabilities to prevent similar attacks in the future. Therefore, a key activity is to perform logging, monitoring and alerting. + +The importance increases because of the dynamic VM/Container deployment. VMs/Containers may be started when demand arises and then quickly be terminated once they are no longer required. Furthermore, the focused nature of VMs/Containers and the application of a microservice architecture means that there are more systems to monitor. As a result, monitoring and logging must handle this dynamic landscape and be able to collect data from many systems at once. + +**Best practices to fulfill this recommendation:** + +| Req ID | Description | +|--------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-LOG-BP-1 | Any change to the O-Cloud components must be logged as a security event, and the logged event must include the identity of the entity making the change, the change, the date and the time of the change. | +| REC-LOG-BP-2 | Security logs should be time synchronized and regularly scanned for events of interest. | +| REC-LOG-BP-3 | Consider monitoring for the presence or loading of known vulnerable software that adversaries may drop and exploit to execute code in kernel mode. | +| REC-LOG-BP-4 | Monitor for the deployment of suspicious or unknown container images and pods in your environment, particularly containers running as root. Additionally, monitor for unexpected usage of syscalls such as mount (as well as resulting process activity) that may indicate an attempt to escape from a privileged container to host. In Kubernetes, monitor for cluster-level events associated with changing containers' volume configurations. | +| REC-LOG-BP-5 | Establish centralized logging for the activity of container and Kubernetes cluster components. This can be done by deploying logging agents on Kubernetes nodes and retrieving logs from sidecar proxies for application pods to detect malicious activity at the cluster level. | +| REC-LOG-BP-6 | Monitor logs for actions that could be taken to gather information about container infrastructure, including the use of discovery API calls by new or unexpected users. Monitor account activity logs to see actions performed and activity associated with the Kubernetes dashboard and other web applications. | +| REC-LOG-BP-7 | Consider monitoring process resource usage to determine anomalous activity associated with malicious hijacking of resources such as CPU, memory, and graphics processing resources. Monitor for suspicious use of network resources associated with cryptocurrency mining software. Monitor for common cryptomining software process names and files on local systems that may indicate compromise and resource usage. | + +| | | +|---------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-LOG-BP-8 | Container administration service activities and executed commands can be captured through logging of process execution with command-line arguments on the container and the underlying host. In Docker, the daemon log provides insight into events at the daemon and container service level. Kubernetes system component logs may also detect activities running in and out of containers in the cluster. | +| REC-LOG-BP-9 | Monitor interactions with images and containers by users to identify ones that are added or modified anomalously. In containerized environments, changes may be detectable by monitoring the Docker daemon logs or setting up and monitoring Kubernetes audit logs depending on registry configuration. | +| REC-LOG-BP-10 | Monitor for suspicious or unknown container images and pods in your environment. Deploy logging agents on Kubernetes nodes and retrieve logs from sidecar proxies for application pods to detect malicious activity at the cluster level. In Docker, the daemon log provides insight into remote API calls, including those that deploy containers. Logs for management services or applications used to deploy containers other than the native technologies themselves should also be monitored. | +| REC-LOG-BP-11 | Monitor for unexpected Docker image build requests to the Docker daemon on hosts in the environment. Additionally monitor for subsequent network communication with anomalous IPs that have never been seen before in the environment that indicate the download of malicious code. | +| REC-LOG-BP-12 | Alert the incident responders about a breach / attack on the O-Cloud software via email, SMS or other notification mechanisms. | +| REC-LOG-BP-13 | Alert using a notification to RASP (Runtime application self-protection) modules, or a SIEM about a breach / attack on the O-Cloud software. | + +**This recommendation can help to mitigate:** T-GEN-01, T-GEN-02, T-GEN-03, T-GEN-06, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-VM-C-06, T-IMG-01, T-IMG-02, T-IMG-04, T-VL-02, T-TS-01 + +## 8.10 REC-SB Secure Boot + +**Recommendation:** All servers that are part of O-Cloud Infrastructure should support a root of trust and secure boot to trust that the running host OS, Hypervisor/Container Engine and VNFs/CNFs code were loaded. + +**Best practices to fulfill this recommendation:** + +| Req ID | Description | +|-------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-SB-BP-1 | Using trusted platform module (TPM) as a hardware root of trust, the measurement of system sensitive components such as platform firmware, BIOS, bootloader, OS kernel, and other system components can be securely stored and verified. The platform measurement can only be taken when the system is reset or rebooted; there is no way to write the new platform measurement in TPM during the system run-time. The validation of the platform measurements can be performed by TPM's launch control policy (LCP) or through the remote attestation server. | + +For more details see ETSI GR NFV-SEC 007 [i.15]. + +**This recommendation can help to mitigate:** T-GEN-03, T-IMG-04, T-VL-01, T-VL-02 + +## 8.11 REC-ISO Strong Isolation + +**Recommendation:** Strong VNFs/CNFs sandboxing, isolation and segmentation should be enforced to make difficult for adversaries to advance their operation through exploitation of undiscovered or unpatched vulnerabilities. O-Cloud virtualization layer shall adopt measures to ensure strong VM/Container isolation among VM/Container workloads to limit the impact of rogue/misbehaving VM/Container on other co-hosted VMs/Containers. + +### Best practices to fulfill this recommendation: + +| Req ID | Description | +|--------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-ISO-BP-1 |

In order to prevent privilege escalations, Operators shall ensure that CNFs shall:

  • • Avoid using binaries with SUID or SGID bit. Instead, specific capabilities required by the files/binaries should be provided using Linux Capabilities set
  • • Avoid root user and sudo privileges within container
| +| REC-ISO-BP-2 |

Restrict the damage attackers can do once they successfully escaped a container. Again, the Linux kernel provides a couple of security features that can be used to restrict user actions. Among them are Linux security modules providing mandatory access control and user namespaces themselves.

| +| REC-ISO-BP-3 |

Restrict the large system call interface using seccomp. The seccomp ('Secure Computing') integrates a BPF-like filter mechanism for system calls into the Linux kernel. This can be used to reduce the number of system calls that a container can effectively use. Moreover, the parameters to system calls can be sanitized. Thus, seccomp reduces one attack surface by reducing the number of exploitable system calls.

| +| REC-ISO-BP-4 |

Linux kernel allows to restrict users' capabilities to perform specific operations. In particular, root users have a vast set of permissions. Linux capabilities permit a fine-grained partition of the capabilities bundled into the root user. Thus, instead of being root, different capabilities can be restricted. For example, a user can be root without having the permissions to change network settings. Currently, the Linux kernel has 37 capabilities. Unfortunately, not all capabilities have a specific, well-defined scope. For example, CAP_SYS_PTRACE permits the use of ptrace(), while CAP_SYS_ADMIN comprises many permissions such as changing the host and domain name, using mount() and umount(), or performing various configurations of storage and memory devices. Restricting capabilities assigned to container processes limits the operations an adversary can use on the host system.

| +| REC-ISO-BP-5 |

Namespaces and cgroups are the two features that enable container-based virtualization in the Linux kernel. They provide isolation and separation of processes. However, their default configuration is often not as restrictive as possible to support many use cases. Thus, it is important to employ many namespaces and cgroups and tighten their configuration.

For example, the user namespace separates the user IDs on the host system from the user IDs of a container. A user within the container can be root, while on the host system the same user is unprivileged. As another example, the devices control group can restrict what device nodes can be created and be accessed. Other control groups limit the maximum resources a container can use. Thus, they prevent degradation or denial of services in a shared environment.

| +| REC-ISO-BP-6 |

Linux security modules (LSM) are software components that use a well-defined kernel interface to control and decline certain operations. In particular, LSMs providing mandatory access control (MAC) define rules that further restrict what files a process can access. Two well-known LSM MACs are AppArmor and SELinux. These MACs define policy rules about what a process can and cannot access. The resulting policies are then enforced by the kernel. Thus, adversaries are on the one side further limited on the resources that are exploitable. On the other hand, they have to invest additional time and resources to circumvent and disable the LSMs.

So far, these security mechanisms mostly protect the host from containers. If a container is compromised, an adversary still has to put in the additional effort to compromise the host. However, these protections may not circumvent exploits across containers on the same host. For example, containers on the Docker engine share a common user namespace and storage space for the container images. Thus, an adversary escaping one container may have access to the container images of another container. This can be used to manipulate images and introduce persistent threats or steal information. One safeguard against these cross-container exploitations are extended features of LSM MACs known as multi category security. Using MCS, every container gets a unique identity when it is initialized. Based on this unique identity, the kernel can perform more fine-grained access decisions because two process executing the same binary that would usually have the same policy are now distinguishable.

| + +| | | +|--------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | As a result, access to container specific resources can be restrict for each container. | +| REC-ISO-BP-7 | It is important to secure remote access to the host and containers themselves. While not going into the details of full network security in a cloud environment, each container and host must be protected as part of the security-in-depth approach. On Linux systems, netfilter/iptables and ebtables can be used to create packet firewalls. They limit network access to exposed ports on the host and in the containers. Similar to virtual switches in hypervisors, containers can be connected by a Linux bridge device. Platforms such as Docker use a default bridge device for all containers if no separate network is specified during container initiation. As a result, containers may share a common network segment, which can be exploited. Therefore, ebtables is recommended as an additional firewall configured for the bridge device. | +| REC-ISO-BP-8 | Stronger isolation mechanisms to keep application code constrained within a VM/Container. Such solutions include the private cloud, physical separation.

For containers, many security solutions 16 are used for ensuring strong isolation of resources, such as LXC, LXD, Singularity, Docker (runc), Kata-containers (kata-runtime), and gVisor (runsc). | +| REC-ISO-BP-9 | Shared cache memory partitioning or isolation and assigning of a separate portion of cache memory to each VM can reduce or eliminate successful side channel attacks in a virtualized environment 17 . | + +**This recommendation can help to mitigate:** T-GEN-01, T-VM-C-01, T-VM-C-02, T-VM-C-05, T-VL-01, T-HW-01 + +## 8.12 REC-AUD Security Audit + +**Recommendation:** Periodic audit and scan should be conducted of: + +- The integrity of images and VM/Containers used in O-Cloud deployments to ensure they have not been modified to include malicious software. +- Accounts and privileges for images repositories. +- All accounts, access lists and the privileges they have been granted to access O-Cloud components and images repositories. + +**Best practices to fulfill this recommendation:** + +| Req ID | Description | +|--------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-AUD-BP-1 | Scan code repositories for exposed credentials or other sensitive information. Preemptively search for files containing passwords or other credentials and take actions to reduce the exposure risk when found. | +| REC-AUD-BP-2 | Suspicious accounts/credentials should be investigated and removed. | +| REC-AUD-BP-3 | Routinely check account role permissions to ensure only expected users and roles have permission to modify cloud firewalls, to modify cloud compute infrastructure components, create snapshots and backups, and to create/delete new instances. | + +**This recommendation can help to mitigate:** T-GEN-01, T-GEN-02, T-VM-C-05, T-IMG-01, T-IMG-03, T-IMG-04, T-ADMIN-01, T-ADMIN-02 + +16 Olivier Flauzac, Fabien Mauhourat, Florent Nolot, A review of native container security for running applications, Procedia Computer Science, Volume 175, 2020, Pages 157-164, ISSN 1877-0509, . "A review of native container security for running applications" + +17 + +## 8.13 REC-SS Secure Storage + +**Recommendation:** The O-Cloud infrastructure should support encrypted storage, for example, block, object, file storage, credentials, and secrets with access to encryption keys restricted based on a need to know. + +**Best practices to fulfill this recommendation:** + +| Req ID | Description | +|-------------|------------------------------------------------------------------------------------------------------------------------------------------| +| REC-SS-BP-1 | Controlled Access Based on the Need to Know should be implemented 18 . | +| REC-SS-BP-2 | When possible, store keys on separate cryptographic hardware (e.g. HSM, TPM) instead of on the local system. | +| REC-SS-BP-3 | Use best practices for authentication protocols, such as OAuth 2.0, and ensure traffic that may contain credentials is protected by TLS. | +| REC-SS-BP-4 | Set up monitoring to track access to cache data and identify any unauthorized access attempts. | +| REC-SS-BP-5 | Establish policies for cache data lifecycle, including how long data should be retained in cache and when it should be purged. | + +**This recommendation can help to mitigate:** T-GEN-06, T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-06, T-IMG-03, T-IMG-03, T-VL-01, T-OCAP-01, T-HW-01 + +## 8.14 REC-PHY Physical Security Protection + +**Recommendation:** Physical security protection measures should be considered to deny unauthorized access to O-Cloud facilities, equipment and resources. + +**Best practices to fulfill this recommendation:** + +| Req ID | Description | +|--------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-PHY-BP-1 | Reduce the hardware platform (computing platform based for example on the x86 hardware architecture (32bit or 64bit), similar servers) attack surface by removing unneeded interfaces.

Example: Wireless interfaces (e.g., WiFi, 4G), if present, should remain optional for the platform REC-PHY-BP-1 [i.41]. | +| REC-PHY-BP-2 | Enforce protection of the main memory against untrusted peripherals.

Example: The hardware platform exposes an input/output memory management unit, such as VT-x (Intel) or AMD-V (AMD). This feature needs to be enabled by default and can only be disabled by the owner of the hardware platform (not the user) [i.41]. | +| REC-PHY-BP-3 | Ensure the security hardware component quality.

Example: In case the platform embeds a TPM, the latter is certified (e.g. from a Common Criteria perspective according to the Protection Profile TCG Protection Profile PC Client Specific TPM Family 2.0) [i.41].

Only the owner of the hardware platform (not the user) can enable and disable the TPM. | +| REC-PHY-BP-4 | Ensure the hardening of the platform against persistent compromises.

Example: hardware platform firmwares are expected to ensure their integrity by means of state-of-the-art security mechanisms. This notably includes protecting integrity of the code and data stored | + +18 + +| | | +|---------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |

on the Flash Memory. The modification of firmware code should only be the result of a legitimate, signed update using robust cryptographic protocols. The installation of a signed update older than the version currently installed on the hardware platform shall be considered illegitimate by default. However, for the latter case, the firmware configuration interface shall allow the platform owner to disable this protection.

| +| REC-PHY-BP-5 |

Ensure the presence of minimal security features within the firmware (Low-level software components shipped with the hardware platform, including UEFI and legacy BIOSes or hardware components embedded software).

Example: The firmware configuration interface provides the following features [i.41]:

  • Protecting the access to the firmware configuration interface thanks to a dedicated password
  • Locking the boot sequence of the platform thanks to a dedicated password
  • Enabling and disabling input/output interfaces (e.g. USB)
  • Configuring the boot order (the ordering of the list of devices checked by the BIOS to boot an operating system)
  • Replacing default Secure Boot keys with custom keys generated by the owner
| +| REC-PHY-BP-6 |

Allow for inspecting and auditing firmware code.

Example: Mechanisms which prevent firmware code inspection shall be absent or disabled by default.

| +| REC-PHY-BP-7 |

Data centre physical security protections based on its location and such risk assessments, to determinate the structures, and data centre support systems (sensors, video camera, alarms to a Security Operation Centre...)

| +| REC-PHY-BP-8 |

Backup system in other area if needed.

| +| REC-PHY-BP-9 |

Enforcing Multi-Factor Authentication for privileged users could be a mitigation.

| +| REC-PHY-BP-10 |

Server cabinets fitted with an electronic lock.

| +| REC-PHY-BP-11 |

Physical Access Control based system with video and entry logs system.

| +| REC-PHY-BP-12 |

Sensors on the room or the cabinet to generate alarms to the Network / Security Operation Centre.

| +| REC-PHY-BP-13 |

Limited number of physical interfaces on the on-board NIC of the server and remotely control NIC.

| +| REC-PHY-BP-14 |

Secure All Endpoints (terminal, physical connectivity...).

| +| REC-PHY-BP-15 |

Zero trust architecture with security layers including physical access and redundancies, with regular security audit if needed.

| + +**This recommendation can help to mitigate:** T-VM-C-03, T-VM-C-05, T-VL-02, T-OCAPI-01, T-HW-01, T-HW-02 + +## 8.15 REC-RA Remote Attestation + +**Recommendation:** A remote attestation (RA) approach should be used to determine the trustworthiness of O-Cloud components. It is a defensive measure that addresses the malicious software execution. In O-Cloud it is obvious the need for applying procedures to verify the integrity of the whole O-Cloud service deployment by the appropriate attestation of the O-Cloud architectural elements, including software and firmware images and associated supporting security sub-systems that will run to instantiate individual VNFs/CNFs and their composition into a O-Cloud service. + +The remote attestation requires identifying the root(s) of trust, establishing a chain of trust for the O-Cloud infrastructure, the VL, VNFs/CNFs, and the NFO/FOCOM sub-systems, and verification of the trust chain, so the NFO/FOCOM components can verifiably establish a sufficient level of assurance in the different software elements constituting the VNFs/CNFs and the service(s) that use them. + +The remote attestation (RA) capabilities should be used to realize trust establishment in the following use case scenarios: + +1. Measurement of VM/Container during launch. +2. Protected VM/Container launch on a trusted O-Cloud platform +3. Measurement of VM/Container during launch and while in use +4. Remote attestation of secret storage +5. Secure VM/Container migration between two trusted O-Cloud platform + +**Best practices to fulfill this recommendation:** + +| Req ID | Description | +|-------------|--------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-RA-BP-1 | ETSI GR NFV-SEC 018 [i.13], [i.14], ETSI GR NFV-SEC 007 [i.15] could be used as a security guidance of the remote attestation (RA) approach. | +| REC-RA-BP-2 | All servers part of O-Cloud infrastructure should support measured boot and an attestation server that monitors the measurements of the servers. | + +**Example:** Operators might use RA to assess if the overall O-Cloud infrastructure is trustworthy, datacenters might use RA to assess trustworthiness of subsystems they use, and management entities might use RA to assess the trustworthiness of individual infrastructural components. Hence, there are numerous use-cases and scenarios that might be considered where attestation is a fundamental step of creating an overall trustworthy system. + +A trustworthy element is the entity which has a component that provides a unique identifier, certification (e.g. through cryptographic signing) and which is able to store measurements and data about the state of that element (including related sub-elements or dependent elements if necessary) in a tamperproof and verifiable form. For example, the TPM2.0 quoting mechanism using the TPMS\_ATTEST data structure is an example of this. + +**This recommendation can help to mitigate:** T-GEN-03, T-VM-C-04, T-IMG-04, T-VL-02 + +## 8.16 REC-SDD Secure data deletion + +**Recommendation:** The O-Cloud platform should delete cryptographic keys and sensitive data using a secure deletion method from both active and backup storage systems. + +**Best practices to fulfill this recommendation:** + +| BP ID | Description | +|--------------|-----------------------------------------------------------------------------------------------------------------| +| REC-SDD-BP-1 | Review the CSP's policies and SLAs on data deletion to ensure it has a procedure that effectively deletes data. | + +| | | +|--------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-SDD-BP-2 | Secure overwriting is way to overwrite on existing data to be deleted by new data, replaced with zero or random. | +| REC-SDD-BP-3 | Cryptography method to encrypt the data before storing to the cloud storage. In order to delete the data, the encryption key is being destroyed. This makes the data unrecoverable. | +| REC-SDD-BP-4 | Each data center adheres to a strict disposal policy and uses the techniques described to achieve compliance with NIST SP 800-88 Revision 1 “Guidelines for Media Sanitization” [i.48] and DoD 5220.22-M “National Industrial Security Program Operating Manual.” [i.49]. | +| REC-SDD-BP-5 | Physically destroy media that cannot be sanitized by either crush and deform the drive or shred the drive into small pieces. | +| REC-SDD-BP-6 | Limit access to data backups (through use of roles) to know who has access to the data. | +| REC-SDD-BP-7 | Enable application deployment using a security policy where volumes containing sensitive data mounted by the O-Cloud infrastructure to the application, are unmounted after application initialization guard timer, or based on application state monitoring. | +| REC-SDD-BP-8 | Enable applications to delete application sensitive data from their memory / filesystems based on a trigger from O-Cloud infrastructure. | +| REC-SDD-BP-9 | Enable RASP modules to notify applications to delete application sensitive data from their memory / filesystems based on a trigger from O-Cloud infrastructure. | + +**This recommendation can help to mitigate:** T-GEN-05, T-GEN-06, T-VM-C-03 + +## 8.17 REC-IDM O-Cloud ID secure management + +**Recommendation:** To counter threats associated with ID reuse, mismanagement, and redundancy, the O-Cloud should employ robust strategies for ID generation, validation, and lifecycle management. Properly managed IDs reduce risks of data inconsistencies, unauthorized access, and operational inefficiencies. + +**Best practices to fulfil this recommendation:** + +| BP ID | Description | +|---------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-IDM-BP-01 | Adopt the UUID generation method in line with RFC 4122 standards within the O-Cloud system. Ensure each newly created object, whether Containers, Pods, Nodes, or Services, is assigned a unique UUID upon its instantiation. Utilize reputable UUID generation libraries or modules to ensure adherence to the standard. | +| REC-IDM-BP-02 | Implement validation mechanisms ensuring each ID's uniqueness during assignment. | +| REC-IDM-BP-03 | Use database-level constraints to ensure ID uniqueness across the O-Cloud. | +| REC-IDM-BP-04 | Monitor the lifecycle of each ID, providing a clear history of its assignment and usage. | +| REC-IDM-BP-05 | Implement automated processes to detect and remove defunct node objects. | +| REC-IDM-BP-06 | Audit node resources before ID assignment and raise alerts on mismatches. | +| REC-IDM-BP-07 | Use configuration management tools to maintain node consistency. | +| REC-IDM-BP-08 | Employ dynamic IP management systems to ensure consistent IP assignments. | +| REC-IDM-BP-09 | Ensure monitoring tools can differentiate between data from old and new IDs. | + +| | | +|---------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-IDM-BP-10 | Notify users/systems when an ID is reused, alerting them of potential ambiguities. | +| REC-IDM-BP-11 | Centralize logging systems with distinct identifiers for each ID. | +| REC-IDM-BP-12 | Regularly update and audit RBAC policies to ensure they reflect current ID assignments. | +| REC-IDM-BP-13 | Before reusing any ID, ensure that the lifecycle of the previous object associated with that ID has been completely terminated. | +| REC-IDM-BP-14 | For any ID that's about to be reused, conduct thorough data cleaning processes to remove all residual data and configurations associated with its predecessor. | + +**This recommendation can help to mitigate:** T-O-CLOUD-ID-01, T-O-CLOUD-ID-02, T-O-CLOUD-ID-03 + +## 8.18 REC-IDM Identity management for O-Cloud elements + +O-RAN Applications hosted on O-Cloud, Services provided by O-Cloud and O-Cloud Nodes use an identity, such as an identifier in an X.509 certificate, for authentication and authorization. To establish consistent and standardized identities throughout O-Cloud, it is essential to implement a uniform identity provider. + +The incorporation of an Identity Provider framework ensures uniform identity management that provides strong attested identities, through a combination of diverse attestation mechanisms, for the various elements in O-cloud environment and addresses the threats of Identity spoofing, unauthorized access, inadequate verification of the trustworthiness of entities. + +**Recommendation:** SPIRE and SPIFFE are CNCF graduated projects that effectively act as an identity provider for workloads and has been specified in **NIST SP 800-207A** [i.58] which mentions that “service identity should not be subjected to spoofing and should be continuously verifiable. An example of workload identity is a SPIFFE ID which is encoded as a Uniform Resource Identifier (URI) and carried in a cryptographically verifiable document called a SPIFFE Verifiable Identity Document (SVID)”. + +SPIFFE provides a structured ID format for applications in [RFC 3986](#) URI format. The SPIFFE ID adheres to **NIST SP 800-207A** (Zero Trust Architecture Model for Access Control in Cloud-Native Applications) as mentioned above. + +**SPIFFE Runtime Environment** (SPIRE), a production-ready implementation of SPIFFE APIs use **Node** and **workload attestation** to securely issue **SVID** [X.509 certificate with SPIFFE ID][i.55] to Applications which can be used for service-service communication. + +In O-Cloud, services and workloads can be dynamically scaled up, down and scheduled, SPIRE provides a **secure way to verify the identity** of these dynamically changing entities, ensuring that services can **trust** one another in such environments. + +**SPIFFE and SPIRE**, as a part of O-Cloud Infrastructure enable services and applications to obtain identity (SPIFFE ID [i.57]) and SVID [X.509 certificate with SPIFFE ID] using attestation policies. + +![SPIRE Architecture in O-Cloud diagram](5512bb9a76021bc6a412c58de682f1a9_img.jpg) + +The diagram illustrates the SPIRE Architecture within an O-Cloud environment. The O-Cloud is represented by a large dashed blue box. Inside, the O-Cloud infrastructure is shown, containing a SPIRE Server and two nodes (Node-1 and Node-2). The SPIRE Server is a yellow box with a Registration API, a Node API, and a database icon. It is connected to a PKI (Public Key Infrastructure) box outside the O-Cloud. The SPIRE Server communicates with the SPIRE Agents on Node-1 and Node-2. Each node contains a SPIRE Agent (yellow box) with a Workload API. The SPIRE Agents communicate with Workloads (blue boxes) on each node. Each Workload is associated with an SVID Trust Bundle (grey box). A legend at the bottom indicates that yellow boxes represent SPIRE Components. + +SPIRE Architecture in O-Cloud diagram + +Fig 8.18-1: SPIRE Architecture in O-Cloud + +**SPIRE Architecture:** A SPIRE deployment is composed of one or more **SPIRE Servers** and one or more **SPIRE Agents**. + +**SPIRE Server:** A SPIRE Server is responsible for **managing and issuing** all **identities** in its configured SPIFFE trust domain. It stores registration entries [i.54] (which specify the selectors that determine the conditions under which a particular SPIFFE ID should be issued) and signing keys, uses node attestation [i.54] to authenticate agents' identities automatically, and creates SVIDs for workloads when requested by an authenticated agent. + +**SPIRE Agents:** A SPIRE Agent runs on every O-Cloud node on which an identified workload runs. The agent performs the following tasks: + +- Requests SVIDs from SPIRE server and caches them until a workload requests its SVID. +- Exposes the SPIFFE Workload API to workloads on node and attests the identity of workloads that call it. +- Provides SVIDs to the identified workloads. + +### Best practices to fulfil this recommendation: + +| BP ID | Description | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-IDM-SPR-01 | Adopt a uniform standardized identity that follow the URI specification as defined by RFC 3986 for all elements within the O-Cloud.
spiffe://domain/clusterName/namespace/WL-identity | +| REC-IDM-SPR-02 | The SPIFFE Verifiable Identity Document (SVID) is cryptographically verifiable document can be issued either by SPIRE server locally or through an external Certificate Authority. | + +| | | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REC-IDM-SPR-03 | Agent and server architecture model as defined in SPIFFE and SPIRE Concepts [i.54] to be implemented in O-Cloud platform. | +| REC-IDM-SPR-04 | O-Cloud exposes the SPIRE APIs through which identity may be retrieved and/or issued to Applications or services. | +| REC-IDM-SPR-05 |

Registration entries maps an identity -- in the form of a SPIFFE ID -- to a set of properties known as selectors that the workload must possess to be issued a particular identity.

For SPIRE to identify an O-Cloud element, it is essential to register the O-Cloud elements with the SPIRE Server, via registration entries.

SMO can use the O2ims interface to push the registration entries for O-Cloud Nodes, Network Functions to the SPIRE server present as part of the O-Cloud platform.

| +| REC-IDM-SPR-06 |

Attestation Policies are enforced for asserting the identity of O-Cloud elements by gathering attributes and comparing them to a set of selectors defined in the Registration entries.

Node Attestation [i.56] ensures agent authenticate and verify itself when it first connects to a server.

Workload Attestation verifies the identity of the elements by querying information about the process from the node and comparing it with the selectors provided in the Registration entries.

| +| REC-IDM-SPR-07 | SPIRE server as part of O-Cloud platform does issuance of SVID and required trust bundle to O-Cloud elements after successful assertion. | + +**This recommendation can help to mitigate:** T-O-CLOUD-ID-01, T-O-CLOUD-ID-03 + +## 8.19 REC-ADMC Admission Control + +Admission Control, within the framework of O-Cloud, operates as a customizable and adaptable security layer. It intercepts API requests after they are authenticated and authorized but before they are executed. It evaluates and decides on the admission of requests to perform specific actions, such as deploying a software image, creating or updating Pods, managing resources, and setting up network policies. + +Some of the configurable security policies include: + +- **Vulnerability scanning:** The Admission Control incorporates a robust vulnerability scanning process. This process is integral to identifying and assessing any known security vulnerabilities within a software image. It ensures that only those images that meet the set vulnerability thresholds, indicating a minimized risk of security threats, are approved for deployment. The activation of this scanning feature can be adjusted according to the specific needs and security requirements of different scenarios. +- **Image signature verification:** In addition to vulnerability scanning, the Admission Control also includes the critical step of verifying the digital signature of software images. This verification process is essential for confirming the authenticity and integrity of the image. It guarantees that the image originates from a trusted source and remains unaltered. The enforcement of this verification can be tailored based on the operational context and the level of security needed. +- **Resource quotas and limits:** The Admission Control enforces policies on the amount of resources (CPU, memory, storage) that can be consumed by pods or namespaces. This prevents any single application or user from monopolising cluster resources, which can be a security concern in multi-tenant environments. +- **Pod security policies:** The Admission Control defines a set of conditions that a pod must meet before it is accepted into the system. These policies can enforce the use of non-privileged containers, restrict volume types, and require the use of read-only root file systems, all of which enhance security. +- **Immutable containers:** The Admission Control enforces policies that prevent changes to running containers, ensuring that the containers remain in their original, secure state as defined at deployment. +- **API rate limiting:** To prevent abuse and potential denial-of-service attacks, The Admission Control can enforce rate limiting on API requests. This ensures that the API server remains stable and responsive, even under high load or during an attack. + +In Kubernetes, the Admission Control is an integral component that significantly enhance the cluster's security and operational integrity. It can be implemented as a plugin that can either modify or reject requests to the Kubernetes API, ensuring compliance with defined security and operational policies. Examples of a such Admission Control include: + +- Kubernetes Pod Security Admission: Admission Controller provided by Kubernetes itself. It focuses on enforcing security-related best practices for Pods. +- 3rd party admission plugins: such as OPA. Open Policy Agent (OPA) is a popular third-party admission controller. It extends the functionality of Kubernetes admission control by allowing more complex and customized policy enforcement. OPA uses a declarative language called Rego to define policies that specify the desired state and behaviour of the cluster resources. For example, OPA can be used to require that all container images come from a trusted registry. + +In the O-Cloud context, the decision hinges on achieving a delicate balance: on one hand, there's the need for simplicity and seamless integration, which is a strong point of Kubernetes native controllers. On the other hand, there's a demand for advanced, customizable policy management, where OPA excels. Throughout this balancing act, it is crucial to maintain high standards of security and optimal performance, ensuring these implementations are effectively aligned with the broader O-RAN system. Opting for a combination approach might provide the most flexibility, catering to these diverse requirements. This strategy enables the adaptation to varying operational scenarios within O-RAN, each with its own unique set of needs, whether they pertain to security, efficiency, scalability, or compliance. + +**This recommendation can help to mitigate:** T-VM-C-01, T-IMG-01, T-VL-03 + +# --- 9 Risk Assessment + +The risk assessment of the identified threats against O-Cloud is provided in the O-RAN Security Threat Modeling and Risk Assessment [i.50]. + +# Annex A (informative): Best practices from some of existing main security guidance + +Operators, O-Cloud vendors and Cloud providers should ensure that O-Cloud components and interfaces are secure under very strict set of security best practices. Such security guidance include: + +- A.1 CISA/NSA Kubernetes security hardening best practices [i.3] +- A.2 CIS Docker security best practices [i.18] +- A.3 ONAP VNFs security best practices [i.24] + +## A.1 CISA/NSA Kubernetes security hardening best practices + +This section summarizes recommendations and best practices from the CISA/NSA Kubernetes Hardening Guidance. The report details recommendations to harden Kubernetes systems. Primary actions include the scanning of containers and Pods for vulnerabilities or misconfigurations, running containers and Pods with the least privileges possible, and using network separation, firewalls, strong authentication, and log auditing. To ensure the security of applications, system administrators should keep up to date with patches, updates, and upgrades to minimize risk. NSA and CISA also recommend periodic reviews of Kubernetes settings and vulnerability scans to ensure appropriate risks are accounted for and security patches are applied. + +Download the full Kubernetes Hardening Guidance: [https://media.defense.gov/2021/Aug/03/2002820425/-1/-1/1/CTR\\_KUBERNETES%20HARDENING%20GUIDANCE.PDF](https://media.defense.gov/2021/Aug/03/2002820425/-1/-1/1/CTR_KUBERNETES%20HARDENING%20GUIDANCE.PDF) + +### Kubernetes Pod security + +Pods are the smallest deployable Kubernetes unit and consist of one or more containers. Pods are often a cyber actor's initial execution environment upon exploiting a container. For this reason, Pods should be hardened to make exploitation more difficult and to limit the impact of a successful compromise. + +**“Non-root” containers:** Preventing root execution by using non-root containers limits the impact of a container compromise. container engines allow containers to run applications as a non-root user with non-root group membership. Typically, this non-default setting is configured when the container image is built. Having non-root execution integrated at build time provides better assurance that applications will function correctly without root privileges. (See Appendix A in [i.3]). + +**Immutable container file systems:** By default, containers are permitted mostly unrestricted execution within their own context. A cyber actor who has gained execution in a container can create files, download scripts, and modify the application within the container. Kubernetes can lock down a container's file system, thereby preventing many post-exploitation activities. However, these limitations also affect legitimate container applications and can potentially result in crashes or anomalous behavior. To prevent damaging legitimate applications, Kubernetes administrators can mount secondary read/write file systems for specific directories where applications require write access. (See Appendix B in [i.3]). + +**Building secure container images:** Container images are usually created by either building a container from scratch or by building on top of an existing image pulled from a repository. In addition to using trusted repositories to build containers, image scanning is key to ensuring deployed containers are secure. Throughout the container build workflow, images should be scanned to identify outdated libraries, known vulnerabilities, or misconfigurations, such as insecure ports or permissions. One approach to implementing image scanning is by using an admission controller [i.3]. This admission controller could block deployments if the image doesn't comply with the organization's security policies defined in the webhook configuration19. + +**Hardening container engines:** Some platforms and container engines provide additional options to harden the containerized environments. A powerful example is the use of hypervisors to provide container isolation. Hypervisors rely on hardware to enforce the virtualization boundary rather than the operating system. Hypervisor isolation is more secure than traditional container isolation. Container engines running on the Windows operating system can be + +19 The Linux Foundation, "11 Ways (Not) to Get Hacked," 18 07 2018 . + +configured to use the built-in Windows hypervisor, Hyper-V, to enhance security. Additionally, some security focused container engines natively deploy each container within a lightweight hypervisor for defense-in-depth. Hypervisor-backed containers mitigate container breakouts. + +### **Network separation and hardening** + +Cluster networking is a central concept of Kubernetes. Communication between containers, Pods, services, and external services must be taken into consideration. Resource separation and encryption can be an effective way to limit a cyber actor's movement and escalation within a cluster. + +**Namespaces:** Kubernetes namespaces are one way to partition cluster resources among multiple individuals, teams, or applications within the same cluster (See [i.3] for more details). + +**Network policies:** Network policies control traffic flow between Pods, namespaces, and external IP addresses. By default, no network policies are applied to Pods or namespaces, resulting in unrestricted ingress and egress traffic within the Pod network. Pods become isolated through a network policy that applies to the Pod or the Pod's namespace. Once a Pod is selected in a network policy, it rejects any connections that are not specifically allowed by any applicable policy object. (See Appendix E in [i.3] for more details). + +**Resource policies:** In addition to network policies, LimitRange and ResourceQuota are two policies that can limit resource usage for namespaces or nodes. A LimitRange policy constrains individual resources per Pod or container within a particular namespace, e.g., by enforcing maximum compute and storage resources. ResourceQuotas are restrictions placed on the aggregate resource usage for an entire namespace, such as limits placed on total CPU and memory usage. If a user tries to create a Pod that violates a LimitRange or ResourceQuota policy, the Pod creation fails. (See Appendixes F and G in [i.3] for more details). + +**Control plane hardening:** The control plane is the core of Kubernetes and gives users the ability to view containers, schedule new Pods, read Secrets, and execute commands in the cluster. Because of these sensitive capabilities, the control plane should be highly protected. In addition to secure configurations such as TLS encryption, RBAC, and a strong authentication method, network separation can help prevent unauthorized users from accessing the control plane. The Kubernetes API server should be protected (e.g. by firewall, TLS encryption) and not be exposed to the Internet or an untrusted network. + +**Worker node segmentation:** A worker node can be a virtual or physical machine, depending on the cluster's implementation. Because nodes run the microservices and host the web applications for the cluster, they are often the target of exploits. If a node becomes compromised, an administrator should proactively limit the attack surface by separating the worker nodes from other network segments that do not need to communicate with the worker nodes or Kubernetes services. A firewall can be used to separate internal network segments from the external facing worker nodes or the entire Kubernetes service depending on the network. Examples of services that may need to be separated from the possible attack surface of the worker nodes are confidential databases or internal services that would not need to be internet accessible. + +**Encryption:** Administrators should configure all traffic in the Kubernetes cluster—including between components, nodes, and the control plane—to use TLS 1.2 or 1.3 encryption. Encryption can be set up during installation or afterward using TLS bootstrapping, detailed in the Kubernetes documentation20, to create and distribute certificates to nodes. For all methods, certificates must be distributed amongst nodes to communicate securely. + +**Secrets:** Kubernetes Secrets maintain sensitive information, such as passwords, OAuth tokens, SSH and TLS keys. Secrets can be encrypted by configuring data-at-rest encryption on the API server or by using an external Key Management Service (KMS), which may be available through a cloud provider. (See Appendixes H and I in [i.3] for more details). + +**Protecting sensitive cloud infrastructure:** Kubernetes is often deployed on virtual machines in a cloud environment. As such, administrators should carefully consider the attack surface of the virtual machines on which the Kubernetes worker nodes are running. In many cases, Pods running on these virtual machines have access to sensitive cloud metadata services on a non-routable address. These metadata services provide cyber actors with information about the cloud infrastructure and possibly even short-lived credentials for cloud resources. Cyber actors abuse these metadata services for privilege escalation. Kubernetes administrators should prevent Pods from accessing cloud metadata services + +20 + +by using network policies or through the cloud configuration policy. Because these services vary based on the cloud provider, administrators should follow vendor guidance to harden these access vectors. + +### **Authentication and authorization** + +Authentication and authorization are the primary mechanisms to restrict access to cluster resources. Cyber actors can scan for well-known Kubernetes ports and access the cluster's database or make API calls without being authenticated if the cluster is misconfigured. User authentication is not a built-in feature of Kubernetes. However, several methods exist for administrators to add authentication to a cluster. + +**Authentication:** Kubernetes clusters have two types of users: service accounts and normal user accounts. Service accounts handle API requests on behalf of Pods. Authentication is typically managed automatically by Kubernetes through the ServiceAccount Admission Controller using bearer tokens. The bearer tokens are mounted into Pods at well-known locations and can be used from outside the cluster if the tokens are left unsecured. Because of this, access to Pod Secrets should be restricted to those with a need to view them using Kubernetes RBAC. For normal users and admin accounts, there is no automatic authentication method for users. Administrators must add an authentication method to the cluster to implement authentication and authorization mechanisms. The Kubernetes documentation21 lists several ways to implement user authentication including client certificates, bearer tokens, authentication plugins, and other authentication protocols. At least one user authentication method should be implemented. Administrators should not use weak methods such as static password files. Weak authentication methods could allow cyber actors to authenticate as legitimate users. + +**Role-based access control:** RBAC is one method to control access to cluster resources based on the roles of individuals within an organization. RBAC is enabled by default in Kubernetes version 1.6 and newer. Privileges assigned to users, groups, and service accounts should follow the principle of least privilege, giving only required permissions to resources. Users or user groups can be limited to particular namespaces where required resources reside. By default, a service account is created for each namespace for Pods to access the Kubernetes API. RBAC policies can be used to specify allowed actions from the service accounts in each namespace. Access to the Kubernetes API is limited by creating an RBAC Role or ClusterRole with the appropriate API request verb and desired resource on which the action can be applied. Tools exist that can help audit RBAC policies by printing users, groups, and service accounts with their associated assigned Roles and ClusterRoles. (See Appendixes J and K in [i.3] for more details). + +### **Log auditing** + +Logs capture activity in the cluster. Auditing logs is necessary, not only for ensuring that services are operating and configured as intended, but also for ensuring the security of the system. Systematic audit requirements mandate consistent and thorough checks of security settings to help identify compromises. Kubernetes is capable of capturing audit logs for cluster actions and monitoring basic CPU and memory usage information; however, it does not natively provide in-depth monitoring or alerting services. + +**Logging:** System administrators running applications within Kubernetes should establish an effective logging, monitoring, and alerting system for their environment. Logging Kubernetes events alone is not enough to provide a full picture of the actions occurring on the system. Logging should also be performed at the host level, application level, and on the cloud if applicable. These logs can then be correlated with any external authentication and system logs as applicable to provide a full view of the actions taken throughout the environment for use by security auditors and incident responders. Within the Kubernetes environment, administrators should monitor/log the following: + +- API request history +- Performance metrics +- Deployments +- Resource consumption +- Operating system calls +- Protocols, permission changes + +--- + +21 + +- Network traffic +- Pod scaling + +When a Pod is created or updated, administrators should capture detailed logs of the network communications, response times, requests, resource consumption, and any other relevant metrics to establish a baseline. + +RBAC policy configurations should be audited periodically and whenever changes occur to the organization's system administrators. + +Audits of internal and external traffic logs should be conducted to ensure all intended security constraints on connections have been configured properly and are working as intended. + +Logs can be streamed to an external logging service to ensure availability to security professionals outside of the cluster, identify abnormalities as close to real time as possible, and protect logs from being deleted if a compromise occurs. If using this method, logs should be encrypted during transit with TLS 1.2 or 1.3 to ensure cyber actors cannot access the logs in transit and gain valuable information about the environment. (See Appendixes L and M in [i.3] for more details). + +**SIEM platforms:** Security Information and Event Management (SIEM) software collects logs from across an organization's network. SIEM software brings together firewall logs, application logs, and more; parsing them out to provide a centralized platform from which analysts can monitor system security. SIEM tools have variations in their capabilities. Generally, these platforms provide log collection, threat detection, and alerting capabilities. Some include machine learning capabilities, which can better predict system behavior and help to reduce false alerts. Organizations using these platforms in their environment can integrate them with Kubernetes to better monitor and secure clusters. Open-source platforms for managing logs from a Kubernetes environment exist as an alternative to SIEM platforms. + +**Alerting:** Kubernetes does not natively support alerting; however, several monitoring tools with alerting capabilities are compatible with Kubernetes. If Kubernetes administrators choose to configure an alerting tool to work within a Kubernetes environment, there are several metrics for which administrators should monitor and configure alerts. Examples of cases that could trigger alerts include but are not limited to: + +- Low disk space on any of the machines in the environment, +- Available storage space on a logging volume running low, +- External logging service going offline, +- A Pod or application running with root permissions, +- An anonymous account being used or gaining privileges, +- Unusual system calls or failed API calls, +- user/admin behavior that is abnormal (i.e. at unusual times or from an unusual location), and +- Significant deviations from the standard operation metrics baseline. + +**Service meshes:** Service meshes are platforms that streamline microservice communications within an application by allowing for the logic of these communications to be coded into the service mesh rather than within each microservice. Coding this communication logic into individual microservices is difficult to scale, difficult to debug as failures occur, and difficult to secure. Using a service mesh can simplify this for developers. The mesh can: + +- Redirect traffic when a service is down, +- Gather performance metrics for optimizing communications, +- Allow management of service-to-service communication encryption, +- Collect logs for service-to-service communication, +- Collect logs from each service, and +- Help developers diagnose problems and failures of microservices or communication mechanisms. + +**Fault tolerance:** Fault tolerance policies should be put in place to ensure logging service availability. One policy that can be put in place is to allow new logs to overwrite the oldest log files if absolutely necessary in the event of storage capacity being exceeded. If logs are being sent to an external service, a mechanism should be in place for logs to be stored locally if a communication loss or external service failure occurs. Once communication to the external service is restored, a policy should be in place for the locally stored logs to be pushed up to the external server. + +**Tools:** Kubernetes does not include extensive auditing capabilities. However, the system is built to be extensible, allowing users the freedom to develop their own custom solution or to choose an existing add-on that suits their needs. One of the most common solutions is to add additional audit backend services, which can use the information logged by Kubernetes and perform additional functions for users, such as extended search parameters, data mapping features, and alerting functionality. Organizations that already use SIEM platforms can integrate Kubernetes with these existing capabilities. Open-source monitoring tools—such as the Cloud Native Computing Foundation’s Prometheus, Grafana Labs’ Grafana, and Elasticsearch’s Elastic Stack (ELK)—are available to conduct event monitoring, run threat analytics, manage alerting, and collect resource isolation parameters, historical usage, and network statistics on running containers. Scanning tools can be useful when auditing the access control and permission configurations by assisting in identifying risky permission configurations in RBAC. NSA and CISA encourage organizations utilizing Intrusion Detection Systems (IDSs) on their existing environment to consider integrating that service into their Kubernetes environment as well. This integration would allow an organization to monitor for—and potentially kill containers showing signs of—unusual behavior so the containers can be restarted from the initial clean image. Many cloud service providers also provide container monitoring services for those wanting more managed and scalable solutions. + +### **Upgrading and application security practices** + +Security of applications running on Kubernetes orchestrated containers is an ongoing process, and it is vital to keep up with patches, updates, and upgrades. The specific software components vary depending on the individual configuration, but each piece of the overall system should be kept as secure as possible. This includes updating: Kubernetes, hypervisors, virtualization software, plugins, operating systems on which the environment is running, applications running on the servers, and any other software hosted in the Kubernetes environment. + +The Center for Internet Security (CIS) publishes benchmarks for securing software. Administrators should adhere to the CIS benchmarks for Kubernetes and any other relevant system components. Administrators should check periodically to ensure their system's security is compliant with the current security experts' consensus on best practices. Periodic vulnerability scans and penetration tests should be performed on the various system components to proactively look for insecure configurations and zero-day vulnerabilities. Any discoveries should be promptly remediated before potential cyber actors can discover and exploit them. + +As updates are deployed, administrators should also keep up with removing any old components that are no longer needed from the environment. Using a managed Kubernetes service can help to automate upgrades and patches for Kubernetes, operating systems, and networking protocols. However, administrators must still patch and upgrade their containerized applications. + +## **A.2 CIS Docker security best practices** + +CIS Benchmarks are universal security best practices developed by cybersecurity professionals and experts. Each CIS Benchmark provides guidelines for creating a secure system configuration. The following table summarizes recommendations from the CIS Docker Benchmark, specifying how to set up a safe docker configuration. + +Download the full CIS Docker Benchmark: + +### **Host Configuration** + +Create a separate partition for containers + +- Harden the container host +- Update your Docker software on a regular basis +- Manage Docker daemon access authorization wisely +- Configure your Docker files directories, and +- Audit all Docker daemon activity. + +### Docker Daemon Configuration + +- Restrict network traffic between default bridge containers and access to new privileges from containers. +- Enable user namespace support to provide additional, Docker client commands authorization, live restore, and default cgroup usage +- Disable legacy registry operations and Userland Proxy +- Avoid networking misconfiguration by allowing Docker to make changes to iptables, and avoid experimental features during production. +- Configure TLS authentication for Docker daemon and centralized and remote logging. +- Set the logging level to 'info', and set an appropriate default ulimit +- Don't use insecure registries and aufs storage drivers +- Apply base device size for containers and a daemon-wide custom SECCOMP profile to limit calls. + +### Container Images and Build File + +- Create a user for the container +- Ensure containers use only trusted images +- Ensure unnecessary packages are not installed in the container +- Include security patches during scans and rebuilding processes +- Enable content trust for Docker +- Add HEALTHCHECK instructions to the container image +- Remove setuid and setgid permissions from the images +- Use COPY instead of ADD in Dockerfile +- Install only verified packages +- Don't use update instructions in a single line or alone in the Dockerfile +- Don't store secrets in Dockerfiles + +### Container Runtime + +- Restrict containers from acquiring additional privileges and restrict Linux Kernel Capabilities. +- Enable AppArmor Profile. +- Avoid use of privileged containers during runtime, running ssh within containers, mapping privileged ports within containers. +- Ensure sensitive host system directories aren't mounted on containers, the container's root filesystem is mounted as read-only, the Docker socket is not mounted inside any containers. +- Set appropriate CPU priority for the container, set 'on-failure' container restart policy to '5', and open only necessary ports on the container. +- Apply per need SELinux security options, and overwrite the default ulimit at runtime. +- Don't share the host's network namespace and the host's process namespace, the host's IPC namespace, mount propagation mode, the host's UTS namespace, the host's user namespaces. +- Limit memory usage for container and bind incoming container traffic to a specific host interface. + +- Don't expose host devices directly to containers, don't disable the default SECCOMP profile, don't use docker exec commands with privileged and user option, and don't use Docker's default bridge docker0. +- Confirm cgroup usage and use PIDs cgroup limit, check container health at runtime, and always update docker commands with the latest version of the image. + +### Docker Security Operations + +- Avoid image sprawl and container sprawl. + +### Docker Swarm Configuration + +- Enable swarm mode only if needed +- Create a minimum number of manager nodes in a swarm +- Bind swarm services are bound to a specific host interface +- Encrypt containers data exchange on different overlay network nodes +- Manage secrets in a Swarm cluster with Docker's secret management commands +- Run swarm manager in auto-lock mode +- Rotate swarm manager auto-lock key periodically +- Rotate node and CA certificates as needed +- Separate management plane traffic from data plane traffic + +## A.3 ONAP VNFs security best practices + +ONAP provides details on the VNF general security requirements on various security areas such as user access control, network security, ACLs, infrastructure security, and vulnerability management. These requirements cover topics associated with compliance, security patching, logging/accounting, authentication, encryption, role-based access control, least privilege access/authorization. This section summarizes requirements from ONAP, specifying how to integrate and operate VNFs within a robust security environment. + +For more details see the full documentation: + +### VNF General Security Requirements + +This section provides details on the VNF general security requirements on various security areas such as user access control, network security, ACLs, infrastructure security, and vulnerability management. These requirements cover topics associated with compliance, security patching, logging/accounting, authentication, encryption, role-based access control, least privilege access/authorization. The following security requirements need to be met by the O-RAN NFs in a virtual environment: + +1. The VNF must implement and enforce the principle of least privilege on all protected interfaces. +2. The VNF must provide a mechanism (e.g., access control list) to permit and/or restrict access to services on the VNF by source, destination, protocol, and/or port. +3. The VNF should provide a mechanism that enables the operators to perform automated system configuration auditing at configurable time intervals. +4. The VNF provider must follow GSMA vendor practices and SEI CERT Coding Standards when developing the VNF in order to minimize the risk of vulnerabilities. See GSMA NESAS Network Equipment Security Assurance Scheme – Development and Lifecycle Security Requirements Version 1.0 () and SEI CERT Coding Standards (). + +5. The VNF must have all code (e.g., QCOW2) and configuration files (e.g., HEAT template, Ansible playbook, script) hardened, or with documented recommended configurations for hardening and interfaces that allow the Operator to harden the VNF. Actions taken to harden a system include disabling all unnecessary services, and changing default values such as default credentials and community strings. +6. The VNF should support the separation of (1) signaling and payload traffic (i.e., customer facing traffic), (2) operations, administration and management traffic, and (3) internal VNF traffic (i.e., east-west traffic such as storage access) using technologies such as VPN and VLAN. +7. The VNF Provider must have patches available for vulnerabilities in the VNF as soon as possible. Patching shall be controlled via change control process with vulnerabilities disclosed along with mitigation recommendations. +8. The VNF must support only encrypted access protocols, e.g., TLS 1.2/1.3. +9. The VNF must store authentication credentials used to authenticate to other systems encrypted except where there is a technical need to store the password unencrypted in which case it must be protected using other security techniques that include the use of file and directory permissions. Ideally, credentials should rely on a HW Root of Trust, such as a TPM or HSM. +10. VNFs that are subject to regulatory requirements must provide functionality that enables the Operator to comply with ETSI TC LI requirements, and, optionally, other relevant national equivalents. +11. The VNF must be able to authenticate and authorize all remote access. +12. The VNF must log any security event required by the VNF Requirements to Syslog using LOG\_AUTHPRIV for any event that would contain sensitive information and LOG\_AUTH for all other relevant events. +13. If SNMP is utilized, the VNF must support at least SNMPv3 with message authentication. +14. The VNF application processes should not run as root. If a VNF application process must run as root, the technical reason must be documented. +15. Login access (e.g., shell access) to the virtualization layer, whether interactive or as part of an automated process, must be through an encrypted protocol such as TLS 1.2/1.3. +16. The VNF must include a configuration (e.g. a template) that specifies the targeted parameters (e.g. a limited set of ports) over which the VNF will communicate; including internal, external and management communication. +17. Containerized components of VNFs should follow the recommendations for Container Base Images and Build File Configuration in the latest available version of the CIS Docker Community Edition Benchmarks to ensure that containerized VNFs are secure. All non-compliances with the benchmarks must be documented. +18. Containerized components of VNFs should execute in a Docker run-time environment that follows the Container Runtime Configuration in the latest available version of the CIS Docker Community Edition Benchmarks to ensure that containerized VNFs are secure. All non-compliances with the benchmarks must be documented. + +### **VNF Identity and Access Management Requirements** + +The following security requirements for logging, identity, and access management need to be met by the O-RAN NFs in a virtual environment: + +1. The VNF must, if not integrated with the Operator's Identity and Access Management system, support the creation of multiple IDs so that individual accountability can be supported. +2. The VNF must, if not integrated with the operator's IAM system, provide a mechanism for assigning roles and/or permissions to an identity. +3. The VNF must, if not integrated with the Operator's Identity and Access Management system, support multifactor authentication on all protected interfaces exposed by the VNF for use by human users. +4. The VNF must support account names that contain at least A-Z, a-z, and 0-9-character sets and be at least 6 characters in length. + +5. The VNF must, if not integrated with the Operator's Identity and Access Management system, comply with "password complexity" policy and support configurable password expiration. When passwords are used, they shall be complex and shall at least meet the following password construction requirements: (1) be a minimum configurable number of characters in length, (2) include 3 of the 4 following types of characters: upper-case alphabetic, lower-case alphabetic, numeric, and special, (3) not be the same as the UserID with which they are associated or other common strings as specified by the environment, (4) not contain repeating or sequential characters or numbers, (5) not to use special characters that may have command functions, and (6) new passwords must not contain sequences of three or more characters from the previous password. +6. The VNF must allow the Operator to restrict access to protected resources based on the assigned permissions associated with an ID in order to support Least Privilege (no more privilege than required to perform job functions). +7. The VNF must set the default settings for user access to deny authorization, except for a super user type of account. +8. The VNF must not store authentication credentials to itself in clear text or any reversible form and must use salting. +9. The VNF must, if not integrated with the Operator's Identity and Access Management system, support the ability to lock out the userID after a configurable number of consecutive unsuccessful authentication attempts using the same userID. The locking mechanism must be reversible by an administrator and should be reversible after a configurable time period. +10. The VNF must, if not integrated with the Operator's identity and access management system, authenticate all access to protected resources. +11. The VNF must support LDAP in order to integrate with an external identity and access manage system. It MAY support other identity and access management protocols. +12. The VNF must not identify the reason for a failed authentication, only that the authentication failed. +13. The VNF must provide a means to explicitly logout, thus ending that session. +14. The VNF must provide explicit confirmation of a session termination such as a message, new page, or rerouting to a login page. +15. The VNF must, if not integrated with the Operator's Identity and Access Management system, enforce a configurable "terminate idle sessions" policy by terminating the session after a configurable period of inactivity. + +### **VNF API Security Requirements** + +This section covers API security requirements when these are used by the VNFs. Key security areas covered in API security are Access Control, Authentication, Passwords, PKI Authentication Alarming, Anomaly Detection, Lawful Intercept, Monitoring and Logging, Input Validation, Cryptography, Business continuity, Biometric Authentication, Identification, Confidentiality and Integrity, and Denial of Service. + +The O-RAN NFs in a virtual environment needs to meet the following API security requirements: + +1. The VNF should integrate with the Operator's authentication and authorization services (e.g., IDAM). +2. The VNF must implement the following input validation control: Check the size (length) of all input. Do not permit an amount of input so great that it would cause the VNF to fail. Where the input may be a file, the VNF API must enforce a size limit. +3. The VNF must implement the following input validation controls: Do not permit input that contains content or characters inappropriate to the input expected by the design. Inappropriate input, such as SQL expressions, may cause the system to execute undesirable and unauthorized transactions against the database or allow other inappropriate access to the internal network (injection attacks). +4. The VNF must implement the following input validation control on APIs: Validate that any input file has a correct and valid Multipurpose Internet Mail Extensions (MIME) type. Input files should be tested for spoofed MIME types. + +### **VNF Security Analytics Requirements** + +This section covers VNF security analytics requirements that are mostly applicable to security monitoring. The VNF Security Analytics cover the collection and analysis of data following key areas of security monitoring: + +- Anti-virus software +- Logging +- Data capture +- Tasking +- DPI +- API based monitoring +- Detection and notification +- Resource exhaustion detection +- Proactive and scalable monitoring +- Mobility and guest VNF monitoring +- Closed loop monitoring +- Interfaces to management and orchestration +- Malformed packet detections +- Service chaining +- Dynamic security control +- Dynamic load balancing +- Connection attempts to inactive ports (malicious port scanning) + +The following requirements of security monitoring need to be met by the O-RAN NFs in a virtual environment. + +1. The VNF must support Real-time detection and notification of security events. +2. The VNF must support API-based monitoring to take care of the scenarios where the control interfaces are not exposed or are optimized and proprietary in nature. +3. The VNF must support detection of malformed packets due to software misconfiguration or software vulnerability and generate an error to the syslog console facility. +4. The VNF must support proactive monitoring to detect and report the attacks on resources so that the VNFs and associated VMs can be isolated, such as detection techniques for resource exhaustion, namely OS resource attacks, CPU attacks, consumption of kernel memory, local storage attacks. +5. The VNF should operate with anti-virus software which produces alarms every time a virus is detected. +6. The VNF must protect all security audit logs (including API, OS and application-generated logs), security audit software, data, and associated documentation from modification, or unauthorized viewing, by standard OS access control mechanisms, by sending to a remote system, or by encryption. +7. The VNF must log successful and unsuccessful authentication attempts, e.g., authentication associated with a transaction, authentication to create a session, authentication to assume elevated privilege. +8. The VNF must log logoffs. +9. The VNF must log starting and stopping of security logging. + +10. The VNF must log success and unsuccessful creation, removal, or change to the inherent privilege level of users. +11. The VNF must log connections to the network listeners of the resource. +12. The VNF must log the field “event type” in the security audit logs. +13. The VNF must log the field “date/time” in the security audit logs. +14. The VNF must log the field “protocol” in the security audit logs. +15. The VNF must log the field “service or program used for access” in the security audit logs. +16. The VNF must log the field “success/failure” in the security audit logs. +17. The VNF must log the field “Login ID” in the security audit logs. +18. The VNF must not include an authentication credential, e.g., password, in the security audit logs, even if encrypted. +19. The VNF must detect when its security audit log storage medium is approaching capacity (configurable) and issue an alarm. +20. The VNF must support the capability of online storage of security audit logs. +21. The VNF must activate security alarms automatically when a configurable number of consecutive unsuccessful login attempts is reached. +22. The VNF must activate security alarms automatically when it detects the successful modification of a critical system or application file. +23. The VNF must activate security alarms automatically when it detects an unsuccessful attempt to gain permissions or assume the identity of another user. +24. The VNF must include the field “date” in the Security alarms (where applicable and technically feasible). +25. The VNF must include the field “time” in the Security alarms (where applicable and technically feasible). +26. The VNF must include the field “service or program used for access” in the Security alarms (where applicable and technically feasible). +27. The VNF must include the field “success/failure” in the Security alarms (where applicable and technically feasible). +28. The VNF must include the field “Login ID” in the Security alarms (where applicable and technically feasible). +29. The VNF must restrict changing the criticality level of a system security alarm to users with administrative privileges. +30. The VNF must monitor API invocation patterns to detect anomalous access patterns that may represent fraudulent access or other types of attacks or integrate with tools that implement anomaly and abuse detection. +31. The VNF must generate security audit logs that can be sent to Security Analytics Tools for analysis. +32. The VNF must log successful and unsuccessful access to VNF resources, including data. +33. The VNF must support the storage of security audit logs for a configurable period of time. +34. The VNF must have security logging for VNFs and their OSs be active from initialization. Audit logging includes automatic routines to maintain activity records and cleanup programs to ensure the integrity of the audit/logging systems. +35. The VNF must be implemented so that it is not vulnerable to OWASP Top 10 web application security risks. +36. The VNF must protect against all denial-of-service attacks, both volumetric and non-volumetric, or integrate with external denial of service protection tools. + +37. The VNF must be capable of automatically synchronizing the system clock daily with the Operator's trusted time source, to assure accurate time reporting in log files. It is recommended that Coordinated Universal Time (UTC) be used where possible, so as to eliminate ambiguity owing to daylight savings time. +38. The VNF must log the Source IP address in the security audit logs. +39. The VNF must have the capability to securely transmit the security logs and security events to a remote system before they are purged from the system. +40. The VNF should provide the capability of maintaining the integrity of its static files using a cryptographic method. +41. The VNF must log automated remote activities performed with elevated privileges. + +### **VNF Data Protection Requirements** + +This section covers VNF data protection requirements that are mostly applicable to security monitoring. + +1. The VNF MUST provide the capability to restrict read and write access to data handled by the VNF. +2. The VNF MUST Provide the capability to encrypt data in transit on a physical or virtual network. +3. The VNF MUST provide the capability to encrypt data on non-volatile memory. Non-volatile memory is storage that is capable of retaining data without electrical power, e.g. Complementary metal-oxide-semiconductor (CMOS) or hard drives. +4. The VNF SHOULD disable the paging of the data requiring encryption, if possible, where the encryption of non-transient data is required on a device for which the operating system performs paging to virtual memory. If not possible to disable the paging of the data requiring encryption, the virtual memory should be encrypted. +5. The VNF MUST use NIST and industry standard cryptographic algorithms and standard modes of operations when implementing cryptography. +6. The VNF MUST NOT use compromised encryption algorithms. For example, SHA, DSS, MD5, SHA-1 and Skipjack algorithms. Acceptable algorithms can be found in the NIST FIPS publications () and in the NIST Special Publications (). +7. The VNF MUST use, whenever possible, standard implementations of security applications, protocols, and formats, e.g., S/MIME, TLS, SSH, IPSec, X.509 digital certificates for cryptographic implementations. These implementations must be purchased from reputable vendors or obtained from reputable open source communities and must not be developed in-house. +8. The VNF MUST provide the ability to migrate to newer versions of cryptographic algorithms and protocols with minimal impact. +9. The VNF MUST support digital certificates that comply with X.509 standards. +10. The VNF MUST NOT use keys generated or derived from predictable functions or values, e.g., values considered predictable include user identity information, time of day, stored/transmitted data. +11. The VNF MUST provide the capability of using X.509 certificates issued by an external Certificate Authority. +12. The VNF MUST be capable of protecting the confidentiality and integrity of data at rest and in transit from unauthorized access and modification. + +### **VNF Cryptography Requirements** + +This section covers VNF cryptography requirements that are mostly applicable to encryption or protocol methods. + +1. The VNF SHOULD support an automated certificate management protocol such as CMPv2, Simple Certificate Enrollment Protocol (SCEP) or Automated Certificate Management Environment (ACME). +2. The VNF SHOULD provide the capability to integrate with an external encryption service. +3. The VNF MUST use symmetric keys of at least 112 bits in length. + +4. The VNF MUST use asymmetric keys of at least 2048 bits in length. +5. The VNF MUST provide the capability to configure encryption algorithms or devices so that they comply with the laws of the jurisdiction in which there are plans to use data encryption. +6. The VNF MUST provide the capability of allowing certificate renewal and revocation. +7. The VNF MUST provide the capability of testing the validity of a digital certificate by validating the CA signature on the certificate. +8. The VNF MUST provide the capability of testing the validity of a digital certificate by validating the date the certificate is being used is within the validity period for the certificate. +9. The VNF MUST provide the capability of testing the validity of a digital certificate by checking the Certificate Revocation List (CRL) for the certificates of that type to ensure that the certificate has not been revoked. +10. The VNF MUST provide the capability of testing the validity of a digital certificate by recognizing the identity represented by the certificate - the “distinguished name”. +11. The VNF MUST support HTTPS using TLS v1.2 or higher with strong cryptographic ciphers. +12. The VNF MUST support the use of X.509 certificates issued from any Certificate Authority (CA) that is compliant with RFC5280, e.g., a public CA such as DigiCert or Let’s Encrypt, or an RFC5280 compliant Operator CA. + +NOTE: The VNF provider cannot require the use of self-signed certificates in an Operator’s run time environment. + +# Annex: Change history/Change request (history) + +| Date | Revision | Description | +|------------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.01.11 | V01.00.01 | Initial draft version for review | +| 2022.03.03 | V01.00.02 | Update according to notes from the WI core teams. This version addresses ORA-CR009, ORA-CR010, MTR-CR001, ORA.AO-CR011 | +| 2022.03.10 | V01.00.03 | Update according to notes from the WI core teams. This version addresses ALT-CR001 | +| 2022.03.24 | V01.00.04 | Update after spelling check | +| 2022.10.21 | V02.00.00 | Addition of:
  • Threats: T-GEN-05, T-VL-03, T-AAL-01, T-AAL-02
  • Recommendation: REC-SDD
| +| 2022.11.14 | V02.00.01 | Update according to the new O-RAN TR format | +| 2023.02.20 | V03.00.01 | Addition of:
  • AAL interfaces
  • Assets: A-OC-13 to A-OC-20
  • Threats: T-AAL-03 to T-AAL-06
| +| 2023.03.20 | V03.00.02 | Update after spelling check | +| 2023.07.05 | V04.00.01 | Integration of SYM CR 0003 | +| 2023.07.05 | V04.00.02 | References are updated to remove version numbers for O-RAN documents | +| 2023.10.16 | V05.00.01 | Integration of WG11 CR-0011 | +| 2023.10.19 | V05.00.02 | Editorial corrections in scope and references | +| 2023.10.26 | V05.00.03 | Editorial corrections in Clause 4.1 | +| 2024.02.19 | V06.00.01 | Additional of:
  • Threat: T-GEN-06
  • REC-IDM Identity management for O-Cloud elements
  • Critical service: O-Cloud Admission Control Services
| +| 2024.03.05 | V06.00.02 | Addressed editorial comments | +| 2024.03.25 | V06.00.03 | Addressed review comments | +| 2024.06.11 | V06.00.04 | Changes:
  • Definition of 'Sensitive'
  • O-Cloud Admission Control in 'Recommendations and best practices'
  • New definitions for certain terms
  • Alignment of O-Cloud assets with the Threat model
| +| 2024.06.20 | V06.00.05 | Changes:
  • Addition of references to definitions
  • Addition of O-Cloud inventory service details
  • Addition of time synchronization related threat
| +| 2024.07.17 | V06.00.06 | Changes:
  • Corrections to references
  • Correction to remove T-IMG-02 from Clause 8.19 to keep document consistency
  • Regeneration of table of contents
| +| 2024.07.22 | V06.00.07 | Changes:
  • Editorial (format) changes to the below
    • Title of clause 4.3.9
    • Renamed title of "revision history" (this table) as per template
    • Corrected alignment of title on first page
  • Regeneration of table of contents
| +| 2024.07.25 | V06.00.08 | Changes:
  • Editorial (format/typo) corrections

Published as version 07.00

| \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/05eb3369301d418dcb82876643e3db9f_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/05eb3369301d418dcb82876643e3db9f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7429cee58f6b43bf97b2e7ad3fe464ee11aaefc7 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/05eb3369301d418dcb82876643e3db9f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15547aceb1e524165623668b58b2c28cd3e14dc6c6309b856741316a94e85300 +size 4494 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/23d67c44257cbf3ed7c4a5a82b1f9e41_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/23d67c44257cbf3ed7c4a5a82b1f9e41_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d9205af95d95e1fb39011c4567c9a290fd4c7d84 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/23d67c44257cbf3ed7c4a5a82b1f9e41_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a0885440d5cd97ab3c1b8354d2d7cfe7c6f01357e29ed61b43b7431fbc307991 +size 38841 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/32c18302ce5dfed581ce2383200fe9f3_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/32c18302ce5dfed581ce2383200fe9f3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..069ed9500fdb709d76d2998c6fd268a1f410368a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/32c18302ce5dfed581ce2383200fe9f3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b73ba2160213dcd9fd8095baed35cbe859fccaa22323092cca60b76cb53fd996 +size 7852 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/359171a069930c765ab1263b2a654639_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/359171a069930c765ab1263b2a654639_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a1d08acd6a846f47410568f3146fd4d9d4fdec18 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/359171a069930c765ab1263b2a654639_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09a8a45c878fe8b591876f0a13bdd7d98ebfb3d937823c68b1155fb786eea93a +size 24362 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/3eca327934fcf4921aec9541163a1e4a_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/3eca327934fcf4921aec9541163a1e4a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ed948c0d85e08efe70e6749611a2e5d5ada4f64a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/3eca327934fcf4921aec9541163a1e4a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:876f56adfe9284d29650f1c46d077134d022a596790ec13837a87c5b2f857f6e +size 7691 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3a71b98fcfc274b0603208cc5e23601d7fc924a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84a0e505aa8e8fcec39c03736b466858a7c1ef91abe309cdd2974ee18257e23b +size 4531 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/5f19af628e407fc47cc229cb28b0c74d_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/5f19af628e407fc47cc229cb28b0c74d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..02bf807299fa387926f2c807e775f196b92399c4 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/5f19af628e407fc47cc229cb28b0c74d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9f5b7c33fe2aa4e622fe57045b9618ab51006535fd4cd9de7179b4047f2e4df8 +size 18381 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/6a7ddebe31d636a01d36ac5e225e9d08_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/6a7ddebe31d636a01d36ac5e225e9d08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5bd3b264874ea5c2a74f066bada6d9a81bfddacb --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/6a7ddebe31d636a01d36ac5e225e9d08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:60243f56379745968db5ff6e8fd1340429e13ad188b623cf2fb1efbd393fa0eb +size 71444 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/6c5d2fe2435998deda747107ff9b3418_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/6c5d2fe2435998deda747107ff9b3418_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..623ba34852c3d7db3880e0313ab63dd1f3a59de4 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/6c5d2fe2435998deda747107ff9b3418_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bfa9e9b4a5554ee473fd2c2aa3458a763b249deba0d7ed6b62ca6da46394edc4 +size 15897 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/721fd8bad03ea911b51744d701b1a4aa_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/721fd8bad03ea911b51744d701b1a4aa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..444d34b4b2ec6443e539b76b0c8d120f857863be --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/721fd8bad03ea911b51744d701b1a4aa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:22fe24dd5c7f6042a8766011ce1c175eaef6fdc9919f8311e798b8a682fe0017 +size 22345 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/73269dafee299d863bdab3ef4b743124_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/73269dafee299d863bdab3ef4b743124_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ac80b6d9eddb8c7b03d8f9b334b4e3a14e18e0f1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/73269dafee299d863bdab3ef4b743124_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:28de4767da4617c4c54eace388ab62de19286355fe8bb0feb23c87d826395665 +size 18066 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/7ab1b517c19341425ed85387c61e2ebb_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/7ab1b517c19341425ed85387c61e2ebb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9584dea0d9d3a0d16f1b294ba530e9c8dde05b60 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/7ab1b517c19341425ed85387c61e2ebb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f37fe45484007b6f0e00462892ce9d7358811fe836fde7c7f82812fe73cda1b6 +size 67997 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82827af191c934857f3a5a97842fa19fb4aa5978 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54f690c723a011f67b244eeda5cca1f67e7a7784e122d72a637cea1ca968c8f4 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/94220bb4f68889783b714d2c1e688efd_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/94220bb4f68889783b714d2c1e688efd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..110be89972bc173151ea7a56918ca43186d502a3 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/94220bb4f68889783b714d2c1e688efd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:68568c6504db3427d1dd24600fca731b9a302ea86600470cf1e58d2d0019caf8 +size 19121 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/d3faf2da39b0f7d1fdde447b13329ec8_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/d3faf2da39b0f7d1fdde447b13329ec8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f2620650a688a61b34e96f1738657f838e2aa9c --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/d3faf2da39b0f7d1fdde447b13329ec8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:21fcbfe60a9f7c93bd53fd369b1113b4975d968e1ef5c8b2814d1812dfceccfb +size 63775 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/d64d9c8275432ac46ec883c7cd780595_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/d64d9c8275432ac46ec883c7cd780595_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9e9fd292d7f24247bf7a9422ffb0f31543fdb375 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/d64d9c8275432ac46ec883c7cd780595_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9aab2c092e20f24865dc655d859cc8f5a4329e94c67127231f3539f0a85d9dc8 +size 4525 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/f17eb6452df746bd6492315ba294d000_img.jpg b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/f17eb6452df746bd6492315ba294d000_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ae370b0b1edbc2368092805feee51df97309c62d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/f17eb6452df746bd6492315ba294d000_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:98c6120974386f505e7a9900c6787f6f78665dc75d5afd0c85a649431a8fa1e0 +size 25440 diff --git a/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/raw.md b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..b58c0e9e0f4a0a75d4f47b84e35d9c75888180e3 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00/raw.md @@ -0,0 +1,1407 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****OAuth 2.0 Security** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------|----| +| List of figures ..... | 4 | +| List of tables ..... | 5 | +| Foreword..... | 6 | +| Modal verbs terminology ..... | 6 | +| 1 Scope ..... | 7 | +| 1.1 Consideration ..... | 7 | +| 2 References ..... | 7 | +| 2.1 Informative references ..... | 7 | +| 3 Definition of terms, symbols and abbreviations ..... | 8 | +| 3.1 Terms ..... | 8 | +| 3.2 Symbols..... | 9 | +| 3.3 Abbreviations ..... | 10 | +| 4 Study and recommendation from IETF, 3GPP and ETSI on OAuth 2.0 ..... | 10 | +| 4.1 General..... | 10 | +| 4.2 IETF 6749 ..... | 10 | +| 4.3 IETF 8705 ..... | 10 | +| 4.4 3GPP TS 33.122..... | 10 | +| 4.5 ETSI NFV SEC022..... | 10 | +| 5 Threats..... | 10 | +| 5.1 O-RAN Elements & Interfaces ..... | 10 | +| 5.2 Threats Template ..... | 10 | +| 5.3 Potential Threat and Exploits..... | 11 | +| 5.4 OAuth 2.0 Threats..... | 11 | +| 6 Threat Analysis ..... | 12 | +| 6.1 General OAuth 2.0 Threats ..... | 12 | +| 7 Risk Assessment..... | 21 | +| 8 Security Controls..... | 21 | +| 9 OAuth 2.0 Authorization framework ..... | 21 | +| 9.1 Overview..... | 21 | +| 9.2 Key Issues ..... | 22 | +| 9.2.1 Key Issue #1: Registration of O-RAN architecture elements in OAuth authorization server ..... | 22 | +| 9.2.2 Key Issue #2: Provisioning of client ID and secrets to O-RAN architecture elements ..... | 22 | +| 9.2.3 Key Issue #3: Provisioning of authorization grants for O-RAN architecture elements ..... | 22 | +| 9.2.4 Key Issue #4: Revocation of client ID and secrets for O-RAN architecture elements..... | 22 | +| 9.2.5 Key Issue #5: Revocation of authorization grants for O-RAN architecture elements..... | 22 | +| 9.2.6 Key Issue #6 Secure transfer of client secrets to clients..... | 22 | +| 9.2.7 Key Issue #7: Secure transit and storage of access and refresh tokens..... | 22 | +| 9.2.8 Key Issue #8: Defining expiration times for access tokens and client secrets..... | 23 | +| 9.2.9 Key Issue #9: Consumers based on Client_IDs created with valid administration ..... | 23 | +| 9.2.10 Key Issue #10: Scope creation..... | 23 | +| 9.2.11 Key Issue #11: Need to support RBAC (Role Based Access Control) for the O-RAN resource servers ..... | 24 | +| 9.2.12 Key Issue #12: Need to support secure transmission of request and response between client and authorization server, between client and resource server ..... | 24 | +| 9.3 Solutions ..... | 25 | +| 9.3.1 Solution #1: Registration of rApp..... | 25 | +| 9.3.2 Solution #2: Request access token for R1 services..... | 27 | +| 9.3.3 Solution #3: R1 services request with access token..... | 29 | + +| | | | +|---------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------| +| 9.3.4 | Solution #4: Secure transmission of request and response between client to authorization server, between client and resource server for R1, A1 and O2..... | 32 | +| 10 | Study and Recommendation an O-RAN Authorization Server Architecture ..... | 38 | +| 11 | Conclusion..... | 38 | +| Annex: | Change history/Change request (history) ..... | 39 | + +# --- List of figures + +| | | +|----------------------------------------------------------------------------------------|----| +| Figure 9.1-1 OAuth 2.0 framework for O-RAN architecture elements and applications..... | 21 | +| Figure 9.3.1-1 rApp Registration use case sequence diagram..... | 25 | +| Figure 9.3.2-1 Request access token for R1 services use case sequence diagram ..... | 27 | +| Figure 9.3.3-1 R1 Service request using access token use case sequence diagram..... | 29 | +| Figure 9.3.4-1 Transmission between client and authorization server..... | 32 | +| Figure 9.3.4-2 Transmission between client and resource server..... | 33 | +| Figure 9.3.4-3 Tls_client_oauth method..... | 34 | +| Figure 9.3.4-4 Private_key_jwt with JWE method..... | 34 | +| Figure 9.3.4-5 Private_key_jwt method..... | 34 | +| Figure 9.3.4-6 Client_secret_jwt method..... | 35 | +| Figure 9.3.4-7 Client_secret_basic method..... | 35 | +| Figure 9.3.4-8 Client_secret_post method..... | 35 | +| Figure 9.3.4-9 Self_signed_tls_client_auth method..... | 36 | + +# --- List of tables + +| | | +|-------------------------------------------------------------------------------------------------|----| +| Table 5.4-1 OAuth 2.0 Threats ..... | 11 | +| Table 9.3.1-1 rApp Registration use case ..... | 25 | +| Table 9.3.2-1 Request access token for R1 services use case..... | 27 | +| Table 9.3.3-1 R1 Service request using access token use case ..... | 29 | +| Table 9.3.4-1 Use case of secure data transmission between client and authorization server..... | 31 | +| Table 9.3.4-2 Authentication methods..... | 33 | +| Table 9.3.4-3 Authentication methods preferences..... | 36 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The technical report defines the authorization framework for O-RAN elements using OAuth 2.0 and applies to the HTTP and Kafka based APIs [i.13] [i.18] used in the R1, O1, O2, A1, FH m-plane [i.17] and Y1 interfaces. + +For this objective, the present document + +- Defines the procedure flow for token registration process, token request process, token verification process and token authorization process. It will specify the token scope metadata for O-RAN. +- Analyses the existing specifications related to OAuth 2.0 such as O-RAN Security protocol specification, IETF RFC 8705[i.6], IETF RFC 6749[i.5], 3GPP TS29.501[i.3], 3GPP TS 33.122[i.4], 3GPP TS 28.319[i.19] and ETSI NFV SEC-022[i.7]. This is used as input to the present document. +- Analyses the security threat arising from the misuse of the access token and defines the security requirements associated to access token. +- Provides the study and recommendation of an authorization server architecture to overlay on the O-RAN architecture. + +## 1.1 Consideration + +This Technical Report makes the following considerations: + +- O-RAN Alliance WG1 has identified the key functions and interface [i.9] adopted in O-RAN and this will influence the set of assets to be protected for OAuth 2.0 framework. +- This TR will perform a detailed study of the OAuth 2.0 Authorization server for O-RAN Architecture Elements and interface. +- Clause 4.7 in O-RAN Security Protocols Specifications [i.1] will be considered as the baseline text for the OAuth 2.0 framework. +- The recommended security requirements and controls provided in this report will be shared with the impacted O-RAN Alliance working group, such as WG1, WG2, WG3, WG6 and WG10 prior to publishing them as normative. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +[i.1] O-RAN ALLIANCE TS: "O-RAN Security Protocols Specifications" + +[i.2] O-RAN ALLIANCE TS: "O-RAN Security Requirements and Controls Specifications" + +[i.3] 3GPP TS 29.501:"5G System; Network Function Repository Services" + +[i.4] 3GPP TS 33.122:"Security aspects of Common API Framework (CAPIF) for 3GPP northbound APIs" + +[i.5] IETF RFC 6749: "The OAuth 2.0 Authorization Framework" + +[i.6] IETF RFC 8705: "OAuth 2.0 Mutual-TLS Client Authentication and Certificate-Bound Access Tokens" + +[i.7] ETSI GS NFV-SEC 022: "Network Functions Virtualisation (NFV) Release 2; Security; Access Token" + +Specification for API Access" + +- [i.8] IETF RFC 6819: "OAuth 2.0 Threat Model and Security Considerations" +- [i.9] O-RAN ALLIANCE TS: "O-RAN Architecture Description" +- [i.10] 3GPP TS 23.222: "Common API Framework for 3GPP Northbound APIs" +- [i.11] 3GPP TS 29.222: "Common API Framework for 3GPP Northbound APIs" +- [i.12] IETF RFC 2616: "Hypertext Transfer Protocol -- HTTP/1.1" +- [i.13] O-RAN TS: "R1 interface: General Aspects and Principles" ("R1GAP") +- [i.14] O-RAN TS: "Non-RT RIC & A1/R1 Interface: Use Cases and Requirements" ("UCR") +- [i.15] O-RAN TR: "Decoupled SMO" +- [i.16] O-RAN TR: "SMO Security" +- [i.17] O-RAN TS: "Management Plane Specification" +- [i.18] Kafka Documentation +- [i.19] 3GPP TS 29.319: "Management and orchestration; Access control for management services" +- [i.20] O-RAN ALLIANCE TR: "O-RAN Threat Modelling and Risk Assessment" +- [i.21] OpenID Connect Core 1.0 incorporating errata set 2 +- [i.22] IETF RFC 7591: OAuth 2.0 Dynamic Client Registration Protocol + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +**A1:** Interface between non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**Access Token:** credentials used to obtain access. It is a string, usually opaque to the client, representing an authorization issued to the client. Tokens represent specific scopes and durations of access, granted by the resource owner, and enforced by the resource server and authorization server (see [i.5], clause 1.4). + +**Authorization code:** The authorization code is obtained by using an authorization server as an intermediary between the client and resource owner. Instead of requesting authorization directly from the resource owner, the client directs the resource owner to an authorization server (via its user-agent as defined in [RFC2616]), which in turn directs the resource owner back to the client with the authorization code. ([i.5], clause 1.3.1) + +**Authorization Server:** The server issuing access tokens to the client after successfully authenticating the resource owner and obtaining authorization. ([i.5], clause 1.1) + +**Client:** An application making protected resource requests on behalf of the resource owner and with its authorization. The term "client" does not imply any particular implementation characteristics (e.g., whether the application executes on a server, a desktop, or other devices). ([i.5], clause 1.1) + +**Client Credentials:** The client credentials (or other forms of client authentication) can be used as an authorization grant when the authorization scope is limited to the protected resources under the control of the client, or to protected resources + +previously arranged with the authorization server. Client credentials are used as an authorization grant typically when the client is acting on its own behalf (the client is also the resource owner) or is requesting access to protected resources based on an authorization previously arranged with the authorization server. ([i.5], clause 1.3.4) + +**CSRF:** Cross-site request forgery (CSRF) is a web-based attack whereby HTTP requests are transmitted from a user that the web site trusts or has authenticated (e.g., via HTTP redirects or HTML forms). ([i.8], clause 4.4.1.8) + +**Near-Real-Time RAN Intelligent Controller:** An O-RAN Network Function (NF) that enables near-real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. It may include AI/ML (Artificial Intelligence / Machine Learning) workflow including model training, inference and updates. + +**Non-Real-Time RAN Intelligent Controller:** A functionality within SMO that drives the content carried across the A1 interface. It is comprised of the Non-RT RIC Framework and the Non-RT RIC Applications (rApps) whose services are defined below. + +**Non-RT RIC Applications (rApps):** Modular applications that leverage the functionality exposed via the Non-RT RIC Framework's R1 interface to provide added value services relative to RAN operation, such as driving the A1 interface, recommending values and actions that may be subsequently applied over the O1/O2 interface and generating "enrichment information" for the use of other rApps. The rApp functionality within the Non-RT RIC enables non-real-time control and optimization of RAN elements and resources and policy-based guidance to the applications/features in Near-RT RIC. + +**O2:** Interface between SMO framework as specified in Clause 5.3.1 and the O-Cloud for supporting O-RAN virtual network functions. Please refer to [13] for more information. + +**Open Redirector:** An open redirector is an endpoint using a parameter to automatically redirect a user-agent to the location specified by the parameter value without any validation. ([i.5], clause 10.15) + +**R1 Interface:** Interface between rApps and Non-RT RIC Framework via which R1 Services can be produced and consumed. + +**Refresh token:** Refresh tokens are credentials used to obtain access tokens. Refresh tokens are issued to the client by the authorization server and are used to obtain a new access token when the current access token becomes invalid or expires, or to obtain additional access tokens with identical or narrower scope (access tokens may have a shorter lifetime and fewer permissions than authorized by the resource owner). ([i.5], clause 1.5) + +**Resource Owner:** An entity capable of granting access to a protected resource. When the resource owner is a person, it is referred to as an end-user. ([i.5], clause 1.1) + +**Resource Server:** The server hosting the protected resources, capable of accepting and responding to protected resource requests using access tokens. ([i.5], clause 1.1) + +**SMO:** A Service Management and Orchestration framework. + +**User-Agent:** The User-Agent request-header field contains information about the user agent originating the request. This is for statistical purposes, the tracing of protocol violations, and automated recognition of user agents for the sake of tailoring responses to avoid particular user agent limitations. ([i.12], clause 14.43) + +**xApp:** An application designed to run on the Near-RT RIC. Such an application is likely to consist of one or more microservices and at the point of on-boarding will identify which data it consumes and which data it provides. The application is independent of the Near-RT RIC and may be provided by any third party. The E2 enables a direct association between the xApp and the RAN functionality. + +**Y1:** An interface over which RAN analytics services are exposed by the Near-RT RIC to be consumed by Y1 consumers. + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +None + +## 3.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply: + +| | | +|-------------|-------------------------------------------| +| 3GPP | 3rd Generation Partnership Project | +| Near-RT RIC | Near-Real-Time RAN Intelligent Controller | +| rApp | Non-RT RIC Application | +| SMO | Service Management and Orchestration | +| xApp | Near-RT RIC Application | + +# --- 4 Study and recommendation from IETF, 3GPP and ETSI on OAuth 2.0 + +## 4.1 General + +## 4.2 IETF 6749 + +*Editor's note: This clause will do the study related to OAuth 2.0 framework from IETF RFC 6749* + +## 4.3 IETF 8705 + +*Editor's note: This clause will do the study related to OAuth 2.0 Mutual-TLS Client Authentication and Certificate-Bound Access Tokens from IETF RFC 8705* + +## 4.4 3GPP TS 33.122 + +*Editor's note: This clause will do the study related to OAuth 2.0 recommended from 3GPP specification (23.222, 29.222, 33.122, TS29.501)* + +## 4.5 ETSI NFV SEC022 + +*Editor's note: This clause will do the study related to OAuth 2.0 mechanism and definition from ETSI NFV SEC022* + +# --- 5 Threats + +## 5.1 O-RAN Elements & Interfaces + +## 5.2 Threats Template + +Template to present the threat characteristics: + +| | | +|---------------------------|-----------------------------------------------------------------| +| Threat ID | O-RAN threat ID | +| Threat title | [Threat Title will include suitable reference of 3GPP/ETF/ETSI] | +| Threat description | Introduction about the threat | +| Threat type | Spoofing
Tampering
Repudiation | + +| | | +|------------------------|--------------------------------------------------------------------------------------------------| +| | Information disclosure
Denial of Service
Elevation of Privilege | +| Vulnerability | | +| Impact type | Authenticity
Integrity
Non-repudiation
Confidentiality
Availability
Authorization | +| Affected Assets | Asset identification | + +## 5.3 Potential Threat and Exploits + +## 5.4 OAuth 2.0 Threats + +The following threats to OAuth 2.0 have been identified and are analyzed in clause 6– Threat Analysis. + +Table 5.4-1 – OAuth 2.0 Threats + +| Threat-Id | Threat Description (Brief) | +|----------------------------------------------|-------------------------------------------------------------------------------------| +| General OAuth 2.0 Threats | | +| T-OAuth-001 | Obtaining client secrets | +| T-OAuth-002 | Obtaining refresh tokens | +| T-OAuth-003 | Obtaining access tokens | +| T-OAuth-004 | Eavesdropping access tokens | +| T-OAuth-005 | Disclosure of client credentials during transmission | +| T-OAuth-006 | Open redirectors on client | +| T-OAuth-016 | Obtaining authorization by code substitution (OAuth Login) | +| T-OAuth-020 | Access token leak in transport/endpoints | +| T-OAuth-021 | Malicious client obtains existing authorization by fraud | +| T-OAuth-022 | Malicious client obtains authorization | +| T-OAuth-023 | Accidental exposure of passwords at client side | +| T-OAuth-024 | Client obtains scopes without end-user authorization and possible misconfigurations | +| T-OAuth-025 | Client obtains refresh token through automatic authorization | +| T-OAuth-026 | Eavesdropping refresh tokens from authorization server | +| T-OAuth-027 | Obtaining refresh token by online guessing | +| T-OAuth-028 | Refresh token phishing by counterfeit authorization server | +| T-OAuth-029 | Guessing access tokens | +| T-OAuth-030 | Access token phishing by counterfeit resource server | +| T-OAuth-031 | Abuse of token by legitimate resource server or client | +| T-OAuth-032 | Token leakage via log files and http referrers | +| Threats at OAuth Authorization Server | | +| T-OAuth-007 | Password phishing by counterfeit authorization server | +| T-OAuth-008 | Malicious client obtains existing authorization by fraud | +| T-OAuth-009 | Obtaining access tokens from authorization server database | +| T-OAuth-010 | Obtaining client secret from authorization server database | + +| | | +|---------------------------------------|---------------------------------------------------------------------------------------------------------------------------| +| T-OAuth-011 | Online guessing of authorization codes | +| T-OAuth-012 | DoS attacks that exhaust resources | +| T-OAuth-013 | CSRF attack against redirect-uri | +| T-OAuth-014 | Resource owner impersonation | +| T-OAuth-015 | DoS using manufactured authorization "codes" | +| T-OAuth-017 | Obtaining user passwords from authorization server database | +| T-OAuth-018 | Obtaining the resource owner password credentials by online guessing | +| T-OAuth-019 | Obtaining refresh token from authorization server database | +| Access control related Threats | | +| T-OAuth-033 | Attacks from the internet exploit weak authentication and access control to penetrate O-RAN network boundary | +| T-OAuth-034 | An attacker exploits insufficient/improper mechanisms for authentication and authorization to compromise O-RAN components | +| T-OAuth-035 | An attacker gains unauthorized access to R1 services | +| T-OAuth-036 | An attacker gains unauthorized access to data | +| T-OAuth-037 | Attacker exploits missing or improperly defined elements of application's SecurityDescriptor | +| T-OAuth-038 | Malicious access to exposed services using valid accounts | +| T-OAuth-039 | Sensitive data at rest is exposed to an internal attacker | + +# 6 Threat Analysis + +## 6.1 General OAuth 2.0 Threats + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-001 | +| Threat title | Obtaining Client Secrets, IETF RFC 6819[i.8], clause 4.1.1 | +| Threat description | A malicious actor may be able to get access to the secrets of O-RAN elements and obtain the tokens in order to replay its refresh tokens and authorization codes. | +| Threat type | Information disclosure
Elevation of Privilege | +| Impact type | Confidentiality
Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-002 | +| Threat title | Obtaining refresh tokens, IETF RFC 6819[i.8], clause 4.1.2 | +| Threat description | A malicious actor may try to get the file system access of the local storage of O-RAN elements and read the refresh tokens. A malicious actor may use the compromised refresh token for a malicious application. | +| Threat type | Information disclosure | + +| | | +|----------------|-------------------------------------------------------------------------------------------------------------| +| Impact type | Confidentiality | +| Affected Asset | O-RAN Architecture Elements that obtain an access token from an OAuth Authorization Server (eg: rApp, xApp) | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-003 | +| Threat title | Obtaining access tokens, IETF RFC 6819[i.8], clause 4.1.3 | +| Threat description | Access tokens may be stolen by a malicious actor from the local storage if the O-RAN elements store them in a local storage that is accessible to other O-RAN elements or applications without restriction. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | O-RAN Architecture Elements and Applications acting as OAuth clients (eg: rApp, xApp) | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-004 | +| Threat title | Eavesdropping Access Tokens, IETF RFC 6819[i.8], clause 4.3.1 | +| Threat description | A malicious actor may attempt to eavesdrop access tokens in transit from the authorization server to the O-RAN elements and applications | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | O-RAN Architecture Elements and Applications acting as OAuth clients (eg: rApp, xApp) | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-005 | +| Threat title | Disclosure of Client Credentials during Transmission, IETF RFC 6819[i.8], clause 4.3.3 | +| Threat description | A malicious actor may attempt to eavesdrop the transmission of O-RAN elements credentials between the application and authorization server during the O-RAN elements authentication process or during OAuth token requests. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | O-RAN Architecture Elements and Applications acting as OAuth clients (eg: rApp, xApp) | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-006 | +| Threat title | Open Redirectors on Client, IETF RFC 6819[i.8], clause 4.1.5 | +| Threat description | A malicious actor may use an open redirector operated by the O-RAN Applications to construct a redirect URI that will pass the authorization server validation but will send authorization code to an endpoint under the control of a malicious actor. | +| Threat type | Information disclosure | + +| | | +|----------------|--------------------------------------------------------------------------| +| Impact type | Authenticity | +| Affected Asset | O-RAN Elements and Applications acting as OAuth clients (eg: rApp, xApp) | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-007 | +| Threat title | Password phishing by counterfeit authorization server, IETF RFC 6819[i.8], clause 4.2.1 | +| Threat description | A malicious actor may steal confidential data (eg. Password) by intercepting the O-RAN Application's request and exploit the URL endpoints managed by authorization server. | +| Threat type | Information disclosure | +| Impact type | Authenticity | +| Affected Asset | OAuth Authorization Server | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-008 | +| Threat title | Malicious Client Obtains Existing Authorization by Fraud, IETF RFC 6819[i.8], clause 4.2.3 | +| Threat description | A malicious actor may exploit the process of authorization server which automatically process the authorization requests from O-RAN Application that have been previously authorized and try to obtain the authorization code instead of the legitimate O-RAN Application. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | OAuth Authorization Server | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-009 | +| Threat title | Obtaining access tokens from authorization server database, IETF RFC 6819[i.8], clause 4.3.2 | +| Threat description | A malicious actor may obtain access tokens from the authorization server's database by gaining access to the database or launching a SQL injection attack. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | OAuth Authorization Server | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-010 | +| Threat title | Obtaining Client Secret from Authorization Server Database, IETF RFC 6819[i.8], clause 4.3.4 | +| Threat description | A malicious actor may obtain valid client_id/secrets combinations from the authorization server's database by gaining access to the database or launching a SQL injection attack. | +| Threat type | Elevation of Privilege | + +| | | +|----------------|----------------------------| +| Impact type | Authorization | +| Affected Asset | OAuth Authorization Server | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-011 | +| Threat title | Online Guessing of Authorization codes, IETF RFC 6819[i.8], clause 4.4.1.3 | +| Threat description | A malicious actor may try to guess valid authorization code values and send the guessed code value using the grant type code in order to obtain a valid access token. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | OAuth Authorization Server | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-012 | +| Threat title | DoS Attacks That Exhaust Resources, IETF RFC 6819[i.8], clause 4.4.1.11 | +| Threat description | A malicious actor may exhaust the pool of authorization codes of the authorization server by repeatedly directing the O-RAN Application to request the access tokens. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | OAuth Authorization Server | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-013 | +| Threat title | CSRF Attack against redirect-uri, IETF RFC 6819[i.8], clause 4.4.1.8 | +| Threat description | CSRF attacks on OAuth approvals may allow a malicious actor to obtain authorization to OAuth protected resources without the consent of the O-RAN Applications. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | OAuth Authorization server | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-014 | +| Threat title | Resource Owner Impersonation, IETF RFC 6819[i.8], clause 4.4.1.10 | +| Threat description | A malicious actor may exploit an OAuth authorization server's ability to gain authorization without the OAuth 2.0 resource owner's consent by automatically approving the request using existing authenticated session. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | + +| | | +|-----------------------|----------------------------| +| Affected Asset | OAuth Authorization server | +|-----------------------|----------------------------| + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-015 | +| Threat title | DoS Using Manufactured Authorization "codes", IETF RFC 6819 [i.8], clause 4.4.1.12 | +| Threat description | An attacker who owns a botnet may locate the redirect URIs of clients that listen on HTTP, access them with random authorization "codes", and cause a large number of HTTPS connections to be concentrated onto the authorization server. This can result in a denial-of-service (DoS) attack on the authorization server. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | OAuth Authorization Server | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-016 | +| Threat title | Obtaining authorization by code substitution (OAuth Login), IETF RFC 6819 [i.8], clause 4.4.1.13 | +| Threat description | An attacker could attempt to log into an application using a victim's identity. Applications relying on identity data provided by an OAuth protected service API to login users are vulnerable to this threat. | +| Threat type | Information Disclosure | +| Impact type | Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-017 | +| Threat title | Obtaining user passwords from authorization server database, IETF RFC 6819 [i.8], clause 4.4.3.5 | +| Threat description | An attacker may obtain valid username/password combinations from the authorization server's database by gaining access to the database or launching a SQL injection attack. | +| Threat type | Information Disclosure | +| Impact type | Authorization
Information Disclosure | +| Affected Asset | OAuth Authorization Server | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-018 | +| Threat title | Obtaining the resource owner password credentials by online guessing, IETF RFC 6819 [i.8], clause 4.4.3.6 | +| Threat description | An attacker may try to guess valid username/password combinations using the grant type "password". | +| Threat type | Information Disclosure | + +| | | +|----------------|----------------------------| +| Impact type | Authorization | +| Affected Asset | OAuth Authorization Server | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-019 | +| Threat title | Obtaining refresh token from authorization server database, IETF RFC 6819 [i.8], clause 4.5.2 | +| Threat description | This threat is applicable if the authorization server stores refresh tokens as handles in a database. An attacker may obtain refresh tokens from the authorization server's database by gaining access to the database or launching a SQL injection attack. | +| Threat type | Information Disclosure | +| Impact type | Authorization | +| Affected Asset | OAuth Authorization Server | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-020 | +| Threat title | Access token leak in transport/endpoints, IETF RFC 6819 [i.8], clause 4.4.2.1 | +| Threat description | A token may be eavesdropped by an attacker. The token is sent from the server to the client via a URI fragment of the redirect URI. If the communication is not secured or the endpoint is not secured, the token could be leaked by parsing the returned URI. | +| Threat type | Information Disclosure | +| Impact type | Authorization | +| Affected Asset | OAuth Authorization Server, O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-021 | +| Threat title | Malicious Client Obtains Existing Authorization by Fraud, IETF RFC 6819 [i.8], clause 4.2.3 | +| Threat description |

Authorization servers may wish to automatically process authorization requests from clients that have been previously authorized by the user. When the user is redirected to the authorization server's end-user authorization endpoint to grant access, the authorization server detects that the user has already granted access to that particular client. Instead of prompting the user for approval, the authorization server automatically redirects the user back to the client.

A malicious client may exploit that feature and try to obtain such an authorization "code" instead of the legitimate client.

| +| Threat type | Spoofing
Repudiation | +| Impact type | Authorization
Non repudiation | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|-----------------------------------------------------------------------------| +| Threat ID | T-OAuth-022 | +| Threat title | Malicious Client Obtains Authorization, IETF RFC 6819 [i.8], clause 4.4.2.3 | +| Threat description | A malicious client may attempt to obtain a token by fraud. | +| Threat type | Spoofing
Repudiation | +| Impact type | Authorization
Non repudiation | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-023 | +| Threat title | Accidental exposure of passwords at client side, IETF RFC 6819 [i.8], clause 4.4.3.1 | +| Threat description | If the client does not provide enough protection, an attacker could retrieve the passwords for a user. | +| Threat type | Information Disclosure | +| Impact type | Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-024 | +| Threat title | Client obtains scopes without end-user authorization and possible misconfigurations, IETF RFC 6819 [i.8], clause 4.4.3.2 | +| Threat description | An O-RAN Application like a rApp or xApp intentionally or unintentionally obtains a token with scope unknown for, or unintended by, the resource owner. | +| Threat type | Tampering
Elevation of privilege | +| Impact type | Confidentiality
Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-025 | +| Threat title | Client Obtains Refresh Token through Automatic Authorization, IETF RFC 6819 4.4.3.3 [i.8], clause 4.4.3.3 | +| Threat description | An O-RAN application like a rApp or xApp obtains intentionally or unintentionally a long-term authorization represented by a refresh token even if the resource owner did not intend so | +| Threat type | Tampering
Elevation of privilege | +| Impact type | Confidentiality
Authorization | + +| | | +|----------------|-------------------------------------------------| +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | +|----------------|-------------------------------------------------| + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-026 | +| Threat title | Eavesdropping Refresh Tokens from Authorization Server, IETF RFC 6819 [i.8], clause 4.5.1 | +| Threat description | An O-RAN Application like a rApp or xApp may eavesdrop refresh tokens when they are transmitted from the authorization server to the client. | +| Threat type | Tampering
Elevation of privilege | +| Impact type | Confidentiality
Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-027 | +| Threat title | Obtaining Refresh Token by Online Guessing, IETF RFC 6819 [i.8], clause 4.5.3 | +| Threat description | An O-RAN Application like a rApp or xApp may try to guess valid refresh token values and send it using the grant type "refresh_token" in order to obtain a valid access token. | +| Threat type | Tampering
Elevation of privilege | +| Impact type | Confidentiality
Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-028 | +| Threat title | Refresh Token Phishing by Counterfeit Authorization Server, IETF RFC 6819 [i.8], clause 4.5.4 | +| Threat description | An O-RAN Application like a rApp or xApp could obtain valid refresh tokens by proxying requests to the authorization server, given the assumption that the authorization server URL is well-known at development time or can at least be obtained from a well-known resource server | +| Threat type | Tampering
Spoofing
Elevation of privilege | +| Impact type | Confidentiality
Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------|-----------------------------------------------------------| +| Threat ID | T-OAuth-029 | +| Threat title | Guessing Access Tokens, IETF RFC 6819 [i.8], clause 4.6.3 | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | Access to a single user's data is possible where an attacker may place a malicious rApp or xApp and attempt to guess the access token values based on knowledge from other access tokens. | +| Threat type | Tampering
Elevation of privilege | +| Impact type | Confidentiality
Authorization | +| Affected Asset | O-RAN Architecture Elements like the SMO, Near-RT RIC | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-030 | +| Threat title | Access Token Phishing by Counterfeit Resource Server, IETF RFC 6819[i.8], clause 4.6.4 | +| Threat description | An O-RAN Application like a rApp or xApp may sends a valid access token to a counterfeit resource server where the server in turn uses that token to access other services on behalf of the resource owner. | +| Threat type | Tampering
Spoofing
Elevation of privilege | +| Impact type | Confidentiality
Authorization | +| Affected Asset | O-RAN Architecture Elements like the SMO, Near-RT RIC | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-031 | +| Threat title | Abuse of Token by Legitimate Resource Server or Client, IETF RFC 6819 [i.8], clause 4.6.5 | +| Threat description | An O-RAN legitimate resource server which is protecting the resources could possibly use an access token to access another resource server. In a similar manner an O-RAN Application like a rApp or xApp could try to use a token obtained for one server on another resource server | +| Threat type | Tampering
Elevation of privilege | +| Impact type | Confidentiality
Authorization | +| Affected Asset | O-RAN Architecture Elements like the SMO, Near-RT RIC | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-032 | +| Threat title | Token Leakage via Log Files and HTTP Referrers, IETF RFC 6819 [i.8], clause 4.6.7 | +| Threat description | An O-RAN Application like a rApp or xApp could be implemented wrongly with respect to sending the access tokens URI query parameters and subsequently leak the access tokens to the log files and the HTTP "referrer" | +| Threat type | Tampering
Elevation of privilege | +| Impact type | Confidentiality
Authorization | +| Affected Asset | O-RAN Architecture Elements like the SMO, Near-RT RIC | + +# 7 Risk Assessment + +# 8 Security Controls + +# 9 OAuth 2.0 Authorization framework + +## 9.1 Overview + +Figure 9.1 depicts the basic OAuth 2.0 framework for O-RAN architecture elements and applications. This general authorization framework is generalized from clause 1 of IETF RFC 6749 [i.5]. + +![Diagram of the O-RAN OAuth 2.0 Framework showing the interaction between the O-RAN Client, Resource Owner, Authorization Server, and Resource Server.](6a7ddebe31d636a01d36ac5e225e9d08_img.jpg) + +``` + +sequenceDiagram + participant Client as O-RAN Client + participant RO as Resource Owner + participant AS as Authorization Server + participant RS as Resource Server + + Client->>RO: 1. O-RAN Client Authorization Request + RO-->>Client: 2. Resource Owner Authorization Grant + Client->>AS: 3. O-RAN Client Authorization Grant + AS-->>Client: 4. Authorization Server Access Token + Client->>RS: 5. O-RAN Client Access Token + RS-->>Client: 6. Protected Resource + +``` + +The diagram illustrates the O-RAN OAuth 2.0 Framework. It shows the O-RAN Client interacting with three other entities: the Resource Owner, the Authorization Server, and the Resource Server. The process follows six steps: 1. O-RAN Client Authorization Request (Client to Resource Owner), 2. Resource Owner Authorization Grant (Resource Owner to Client), 3. O-RAN Client Authorization Grant (Client to Authorization Server), 4. Authorization Server Access Token (Authorization Server to Client), 5. O-RAN Client Access Token (Client to Resource Server), and 6. Protected Resource (Resource Server to Client). + +Diagram of the O-RAN OAuth 2.0 Framework showing the interaction between the O-RAN Client, Resource Owner, Authorization Server, and Resource Server. + +Figure 9.1-1 OAuth 2.0 framework for O-RAN architecture elements and applications + +O-RAN OAuth 2.0 framework defines four roles from clause 1 of IETF RFC 6749 [i.5]: + +- O-RAN client: An O-RAN client is an O-RAN Architecture Element or Application like an rApp or xApp acting as an OAuth client. +- Authorization server: The server issuing access tokens to the O-RAN client after successfully authenticating the resource owner and obtaining authorization. +- Resource owner: “An entity capable of granting access to a protected resource. When the resource owner is a person, it is referred to as an end-user.” ([i.5], clause 1.1) +- Resource server: “The server hosting the protected resources, capable of accepting and responding to protected resource requests using access tokens.” ([i.5], clause 1.1) + +## 9.2 Key Issues + +- 9.2.1 Key Issue #1: Registration of O-RAN architecture elements in OAuth authorization server +- 9.2.2 Key Issue #2: Provisioning of client ID and secrets to O-RAN architecture elements +- 9.2.3 Key Issue #3: Provisioning of authorization grants for O-RAN architecture elements +- 9.2.4 Key Issue #4: Revocation of client ID and secrets for O-RAN architecture elements +- 9.2.5 Key Issue #5: Revocation of authorization grants for O-RAN architecture elements +- 9.2.6 Key Issue #6 Secure transfer of client secrets to clients + +#### 9.2.6.1 Key issue detail + +The need is to identify + +- How the client secrets are transferred to potential clients +- Whether the client secrets will be known at development time or runtime? + +#### 9.2.6.2 Security threats + +| | | +|-------------|------------------------------------------------------------| +| T-OAuth-001 | Obtaining client secrets | +| T-OAuth-005 | Disclosure of client credentials during transmission | +| T-OAuth-007 | Password phishing by counterfeit authorization server | +| T-OAuth-023 | Accidental exposure of passwords at client side | +| T-OAuth-010 | Obtaining client secret from authorization server database | + +### 9.2.7 Key Issue #7: Secure transit and storage of access and refresh tokens + +#### 9.2.6.1 Key issue detail + +It needs to be identified what possible mechanisms exists to ensure the integrity and confidentiality of access and refresh tokens. + +#### 9.2.6.2 Security threats + +| | | +|-------------|--------------------------------------------------------| +| T-OAuth-002 | Obtaining refresh tokens | +| T-OAuth-003 | Obtaining access tokens | +| T-OAuth-004 | Eavesdropping access tokens | +| T-OAuth-020 | Access token leak in transport/endpoints | +| T-OAuth-026 | Eavesdropping refresh tokens from authorization server | +| T-OAuth-027 | Obtaining refresh token by online guessing | +| T-OAuth-029 | Guessing access tokens | + +### 9.2.8 Key Issue #8: Defining expiration times for access tokens and client secrets + +#### 9.2.8.1 Key issue detail + +It needs to be identified if + +- Access tokens need to be configured with the minimal expiration time and in what use cases +- Client secrets needs to be revoked and refreshed regularly and if so at what intervals + +#### 9.2.8.2 Security threats + +| | | +|-------------|------------------------------------------------------------| +| T-OAuth-007 | Password phishing by counterfeit authorization server | +| T-OAuth-008 | Malicious client obtains existing authorization by fraud | +| T-OAuth-009 | Obtaining access tokens from authorization server database | +| T-OAuth-010 | Obtaining client secret from authorization server database | + +### 9.2.9 Key Issue #9: Consumers based on Client\_IDs created with valid administration + +#### 9.2.9.1 Key issue detail + +It needs to be identified if + +- Consumers who connect are only those validated by administrators +- Dynamic clients are possible or not + +#### 9.2.9.2 Security threats + +| | | +|-------------|----------------------------------------| +| T-OAuth-022 | Malicious client obtains authorization | +|-------------|----------------------------------------| + +### 9.2.10 Key Issue #10: Scope creation + +#### 9.2.10.1 Key issue detail + +It needs to be checked as to how scopes are designed, provisioned and enforced. Key topics are + +- How scopes are designed by the resource servers including the clearance and access levels +- How scopes are transferred the authorization server +- How scopes are requested by the client +- How scopes are created in the authorization server + +#### 9.2.10.2 Security threats + +| | | +|-------------|-------------------------------------------------------------------------------------| +| T-OAuth-022 | Malicious client obtains authorization | +| T-OAuth-024 | Client obtains scopes without end-user authorization and possible misconfigurations | + +### 9.2.11 Key Issue #11: Need to support RBAC (Role Based Access Control) for the O-RAN resource servers + +The O-RAN resource servers need to be accessed by only those users who are authorized to carry out the specific task. Hence, we need a mechanism to design and map the O-RAN resource server to the users for access control. + +#### 9.2.11.1 Key issue detail + +It needs to be checked as to + +- How to limit the access of resources to specified users (least privilege) and only for the intended task. +- How to manage access (assign users to permissions related to the resource servers) in a fast and efficient manner. +- How to retain a role only for the period of time required and no longer. + +#### 9.2.11.2 Security threats + +The threats related to limited access control are below. + +- Malicious attacks with open access to the entire system of assets and data +- Insider threats +- Privilege stagnation over a period of time + +Editor notes: Some of the threats id's such as T-OAuth-033, T-OAuth-034, T-OAuth-035, T-OAuth-036, T-OAuth-037, T-OAuth-038, T-OAuth-039 in clause 5.4 of the present document are mapped and identified in the O-RAN Threat Modelling and Remediation Analysis document [6], need to be discussed further. + +### 9.2.12 Key Issue #12: Need to support secure transmission of request and response between client and authorization server, between client and resource server + +The O-RAN related HTTP clients (e.g.: R1, A1, O2) need to make a request to the authorization server and receive a response with respect to the access token. After that the access token has to be transferred from the client to the resource server. + +#### 9.2.12.1 Key issue detail + +It needs to be checked as to + +- How the client will send request details including credentials related to client\_id and client\_secret to the authorization server +- How the client will receive the response from the authorization server +- How the client will send the access token to the resource server + +#### 9.2.12.2 Security threats + +The threats related to insecure transmission of request and response are + +| | | +|-------------|------------------------------------------------------| +| T-OAuth-001 | Obtaining client secrets | +| T-OAuth-003 | Obtaining access tokens | +| T-OAuth-005 | Disclosure of client credentials during transmission | + +## 9.3 Solutions + +### 9.3.1 Solution #1: Registration of rApp + +#### 9.3.1.1 Background + +This use case allows an rApp to register to the SMO as specified in R1GAP [i.13][i.14]. The registration procedure is specified as part of Service Management and Exposure services in R1GAP [i.13][i.14]. + +#### 9.3.1.2 Solution description + +Table 9.3.1-1 rApp Registration use case + +| Use Case Stage | Evolution/Specification | <>
Related use | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | 1) Register the rApp to the SME services Producer in SMO framework. | | +| Actors and Roles |
  • - rApp in the role of Service Producer and/or Service Consumer
  • - SME in the role of SME services Producer.
| | +| Assumptions | n/a | | +| Preconditions | The rApp is instantiated. | | +| Begins when | The rApp Management SMOS is ready for registration. | | +| Step 1 (M) | The rApp Management SMOS sends a registration request to the SME in the SMO passing relevant information needed. | | +| Step 1 (M) | The SME process the rApp registration request that may include.
  • - performing authentication,
  • - if rApp is authenticated, rAppId will be assigned to rApp.
| | +| Step 3 (M) | Response to the registration request along with the rAppId. | | +| Ends when | The rApp is allocated with an rAppId. | | +| Exceptions | n/a | | +| Post Conditions | The rApp is registered with the SMO framework and an rAppId is allocated to the rApp. | | +| Traceability | REQ-R1-SME-rAppreg-FUN1, REQ-R1-SME-rAppreg-FUN2. | | + +![Sequence diagram for rApp Registration use case. The diagram shows two lifelines: rApp Management SMOS and SME(SMOS). Step 1: rApp Management SMOS sends a registration request to SME(SMOS). Step 2: SME(SMOS) processes the request and assigns an rAppId. Step 3: SME(SMOS) sends the response (rAppId) back to rApp Management SMOS. A note indicates that the rApp Management SMOS assigns the rAppId to the rApp as per the App LCM process. Another note indicates that the SME(SMOS) processes the request by assigning the rAppId using the Authorization service.](7ab1b517c19341425ed85387c61e2ebb_img.jpg) + +``` + +sequenceDiagram + participant RAppMgmt as rApp Management SMOS + participant SME as SME(SMOS) + Note over RAppMgmt, SME: 1 App Manager sends a registration request to the SME service based on endpoint details and passing relevant information needed + RAppMgmt->>SME: + Note over SME: 2 Registration processing assign rAppid using Authorization service + SME-->>RAppMgmt: 3 Response to the registration request (rAppid) + Note over RAppMgmt: rApp Management assign rAppid to rApp as per App LCM process + +``` + +Sequence diagram for rApp Registration use case. The diagram shows two lifelines: rApp Management SMOS and SME(SMOS). Step 1: rApp Management SMOS sends a registration request to SME(SMOS). Step 2: SME(SMOS) processes the request and assigns an rAppId. Step 3: SME(SMOS) sends the response (rAppId) back to rApp Management SMOS. A note indicates that the rApp Management SMOS assigns the rAppId to the rApp as per the App LCM process. Another note indicates that the SME(SMOS) processes the request by assigning the rAppId using the Authorization service. + +Figure 9.3.1-1 rApp Registration use case sequence diagram + +#### 9.3.1.3 Impacts on existing O-RAN architecture elements and interfaces + +R1 interface, rApp and SME are the O-RAN architecture elements and interfaces involved in the proposed use cases as specified in Decoupled SMO [i.15] [i.16]. + +##### 1) Service Management and Exposure (SME) SMOS + +The SME service is introduced in the [i.8] section 3.1. While the SME was initially targeted for management and exposure of rApp services in the [i.8], its services are applicable to any entities within the SMO that fulfil the roles of Service Producer and/or Service Consumer. + +In a decomposed service-based SMO architecture, the SME can be leveraged as a generic SMOS, handling service management and exposure for any SMOSs within SMO. The SME SMOS provides a set of common SMO capabilities that are needed for all SMO Services. + +Several of the SME services are applicable to any SMOSs: + +- SMOS registration, +- SMOS discovery, +- Authentication and authorization to access a SMOS, +- Communication support between SMOS Service Producers and SMOS Service Consumers (SMOS Communication), +- Bootstrap of new SMOSs (optional), +- Heartbeat of SMOSs (optional). + +##### 2) rApp Management (SMOS) + +The rApp management service handles management aspects specific to rApps such as: + +- rApp Configuration Management (CM): enables management of the rApp configuration settings, +- rApp Performance Management (PM): offers support for performance reporting on an rApp performance, or of the rApp communication with the non-RT RIC framework (rApp usage of R1 interface), +- rApp Fault Management (FM): provides the fault reporting capabilities to rApps, so they can consume it to report faults that are related to the rApp, or to the rApp communication with the non-RT RIC framework (rApp usage of R1 interface), +- rApp Logging Information: enables rApps to convey their logging information to the non-RT RIC framework, +- rApp lifecycle management services, that expose services that allow to trigger rApp software lifecycle management. + +#### 9.3.1.4 Solution evaluation + +Key Issue #1: Registration of O-RAN architecture elements in OAuth authorization server + +#### 9.3.1.5 Potential security recommendations + +- OAuth protection of the R1 interface is already mandatory in the O-RAN Security Requirements and Controls Specifications [i.2] SEC-CTL-R1-3. + +### 9.3.2 Solution #2: Request access token for R1 services + +#### 9.3.2.1 Background + +This use case allows an rApp to request an access token for access to R1 services as specified in R1GAP [i.13] [i.14]. The request access procedure is specified as part of Service Management and Exposure services in R1GAP [i.13][i.14]. + +An rApp in the role of Service Consumer will be able to request the token and once the token is available, the rApp in the role of Service Consumer will be able access the R1 Services for which it has been authorized. + +#### 9.3.2.2 Solution description + +Table 9.3.2-1 Request access token for R1 services use case + +| Use case stage | Evolution / Specification | <> Related use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| +| Goal | To enable rApp to request an access token for access to R1 services. | | +| Actors and Roles | rApp in the role of Service Consumer that requests token for access to R1 services.
SME as SMOS in the role of SME services Producer support authorization service | | +| Assumptions | rAppId and credentials have been provisioned. | | +| Pre-conditions | R1 interface is established | | +| Begins when | rApp has determined need for an access token to access R1 services and resources. | | +| Step 1 (M) | rApp sends Access token request containing the rAppId and optionally token scope, | SPS [i.1], clause 4.7.2.3 | +| Step 2 (M) | SME authenticate the rApp and if the rApp token request is authorized, then an access token is generated. | SPS [i.1], clause 4.7.2.3 | +| Step 3 (M) | SME respond with access token. | SPS [i.1], clause 4.7.2.3 | +| Ends when | rApp has received an access token for access to R1 services. | | +| Exceptions | n/a | | +| Post-conditions | The rApp is authorized for accessing R1 services. | | +| Traceability | REQ-R1-A-FUN1 | | + +![Sequence diagram for Request access token for R1 services use case. The diagram shows two lifelines: rApp (Service Consumer) and SME (SMOS) (SME services Producer). The rApp sends a message '1 <> Access token request (rAppId)' to the SME. The SME performs a self-call '2' with a note: 'Check Authorization (Authenticate the rApp and check if authorized, if rApp is authorized, generate an access token)'. The SME then sends a message '3 <> Access token response (access token)' back to the rApp.](23d67c44257cbf3ed7c4a5a82b1f9e41_img.jpg) + +``` + +sequenceDiagram + participant rApp as rApp + participant SME as SME (SMOS) + rApp->>SME: 1 <> Access token request (rAppId) + Note over SME: 2 Check Authorization (Authenticate the rApp and check if authorized, if rApp is authorized, generate an access token) + SME-->>rApp: 3 <> Access token response (access token) + +``` + +Sequence diagram for Request access token for R1 services use case. The diagram shows two lifelines: rApp (Service Consumer) and SME (SMOS) (SME services Producer). The rApp sends a message '1 <> Access token request (rAppId)' to the SME. The SME performs a self-call '2' with a note: 'Check Authorization (Authenticate the rApp and check if authorized, if rApp is authorized, generate an access token)'. The SME then sends a message '3 <> Access token response (access token)' back to the rApp. + +Figure 9.3.2-1 Request access token for R1 services use case sequence diagram + +#### 9.3.2.3 Impacts on existing O-RAN architecture elements and interfaces + +R1 interface, rApp and SME are the O-RAN architecture elements and interfaces involved in the proposed use cases as specified in Decoupled SMO [i.15] [i.16]. + +##### 1) Service Management and Exposure (SME) SMOS + +The SME service is introduced in the [i.8] section 3.1. While the SME was initially targeted for management and exposure of rApp services in the [i.8], its services are applicable to any entities within the SMO that fulfil the roles of Service Producer and/or Service Consumer. + +In a decomposed service-based SMO architecture, the SME can be leveraged as a generic SMOS, handling service management and exposure for any SMOSs within SMO. The SME SMOS provides a set of common SMO capabilities that are needed for all SMO Services. Several of the SME services are applicable to any SMOSs: + +- SMOS registration, +- SMOS discovery, +- Authentication and authorization to access a SMOS, +- Communication support between SMOS Service Producers and SMOS Service Consumers (SMOS Communication), +- Bootstrap of new SMOSs (optional), +- Heartbeat of SMOSs (optional). + +##### 2) SME functions in the role of SME services Producer + +- supports the functionality of OAuth 2.0 Authorization server, +- support authentication and authorization of an rApp to determine which R1 services an rApp can access, +- provide response of success or failure to access token request. + +##### 3) rApp + +- supports initiating the procedure to request access token, +- supports initiating service request with the available access token. + +#### 9.3.2.4 Solution evaluation + +Key Issue #3: Provisioning of authorization grants for R1 services + +#### 9.3.2.5 Potential security recommendation + +- Use OAuth 2.0, as specified in O-RAN Security Protocols Specifications [i.1], clause 4.7 to implement authorization in the R1 interface. +- Enable rApp to request OAuth 2.0 access tokens for R1 services. +- Enable the SME to act as both an OAuth 2.0 resource and an OAuth 2.0 Authorization server. + +### 9.3.3 Solution #3: R1 services request with access token + +#### 9.3.3.1 Background + +This use case discuss R1 service Producer to verify that rApp is authorized to access the R1 service as specified in R1GAP [i.13] [i.14]. The service request procedure is specified as part of Service Management and Exposure services in R1GAP [i.13][i.14]. + +#### 9.3.3.2 Solution description + +Table 9.3.3-1 R1 Service request using access token use case + +| Use case stage | Evolution/specification | <> Related use | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------| +| Goal | To enable R1 service Producer to verify that rApp is authorized to access the R1 service. | | +| Actors and Roles | rApp in the role of Service Consumer that requests access to an R1 service with access token.
R1 service producer in the role of SME services Producer that supports the validation of the access token and provides access to the requested service. | | +| Assumptions | rApp has requested and received an access token for the R1 service for which service access is requested. | | +| Pre-conditions | R1 interface is established. | | +| Begins when | rApp initiates a request for an R1 Service to R1 Service producer. | | +| Step 1 (M) | rApp sends service request containing an access token to R1 service Producer | | +| Step 2 (M) | R1 service Producer verifies integrity and claims in the access token. If successful, the requested service is executed. | SPS [i.1]
clause 4.7.2.4] | +| Step 3 & 4 (M) | R1 service Producer sends response to the service request if it has valid token | | +| Step 5 & 6 (O) | The verification of integrity and claims in step 3 was unsuccessful due to invalid or expired token, the requested service is not executed, and R1 service Producer sends a response with appropriate error code. | | +| Ends when | R1 service Producer has responded to the service request. | | +| Post-conditions | - | | +| Traceability | REQ-R1-SME-A-FUN2 | | + +![Sequence diagram for R1 Service request using access token use case. The diagram shows three lifelines: rApp, SME, and R1 service Producer. The R1 service Producer is part of the SME lifeline. The sequence is: 1. rApp sends 'Service request (access token)' to R1 service Producer. 2. R1 service Producer performs a self-call 'Validate token (Verify integrity and claims in the access token. If successful, execute the requested service)'. 3. R1 service Producer sends 'Valid Token' to SME. 4. SME sends 'Service response (success)' to rApp. 5. R1 service Producer sends 'Invalid or Expired Token' to SME. 6. SME sends 'Service response (failure)' to rApp. An 'alt' block encloses steps 3-6.](d3faf2da39b0f7d1fdde447b13329ec8_img.jpg) + +``` + +sequenceDiagram + participant rApp + participant SME + participant R1_service_Producer as R1 service Producer + + Note over SME,R1_service_Producer: alt + R1_service_Producer->>R1_service_Producer: 2 Validate token +(Verify integrity and claims +in the access token. +If successful, execute +the requested service). + R1_service_Producer->>SME: 3 Valid Token + SME->>rApp: 4 <> Service response (success) + R1_service_Producer->>SME: 5 Invalid or Expired Token + SME->>rApp: 6 <> Service response (failure) + end + + rApp->>R1_service_Producer: 1 <> Service request (access token) + +``` + +Sequence diagram for R1 Service request using access token use case. The diagram shows three lifelines: rApp, SME, and R1 service Producer. The R1 service Producer is part of the SME lifeline. The sequence is: 1. rApp sends 'Service request (access token)' to R1 service Producer. 2. R1 service Producer performs a self-call 'Validate token (Verify integrity and claims in the access token. If successful, execute the requested service)'. 3. R1 service Producer sends 'Valid Token' to SME. 4. SME sends 'Service response (success)' to rApp. 5. R1 service Producer sends 'Invalid or Expired Token' to SME. 6. SME sends 'Service response (failure)' to rApp. An 'alt' block encloses steps 3-6. + +Figure 9.3.3-1 R1 Service request using access token use case sequence diagram + +Editor Notes: “whether or not it is required for all API accesses to go through the SME need to be discussed further”. + +#### 9.3.3.3 Impacts on existing O-RAN architecture elements and interfaces + +R1 interface, rApp and SME are the O-RAN architecture elements and interfaces involved in the proposed use cases as specified in Decoupled SMO [i.15] [i.16]. + +##### 1) Service Management and Exposure (SME) SMOS + +The SME service is introduced in the [i.13] section 3.1. While the SME was initially targeted for management and exposure of rApp services in the [i.13], its services are applicable to any entities within the SMO that fulfil the roles of Service Producer and/or Service Consumer. + +In a decomposed service-based SMO architecture, the SME can be leveraged as a generic SMOS, handling service management and exposure for any SMOSs within SMO. The SME SMOS provides a set of common SMO capabilities that are needed for all SMO Services. + +Several of the SME services are applicable to any SMOSs: + +- SMOS registration, +- SMOS discovery, +- Authentication and authorization to access a SMOS, +- Communication support between SMOS Service Producers and SMOS Service Consumers (SMOS Communication), +- Bootstrap of new SMOSs (optional), +- Heartbeat of SMOSs (optional). + +##### 2) SME in the role of SME services Producer + +- supports the functionality of OAuth 2.0 Authorization server, +- support authentication and authorization of an rApp to determine which R1 services an rApp can access, +- provide response of success or failure to access token request + +##### 3) rApp + +- initiating the procedure to request access token, +- initiating service request with the available access token. + +##### 4) R1 Service Producer + +- provider of an R1 service. + +#### 9.3.3.4 Solution evaluation + +Key issue #6: Provisioning of service access based on access token + +#### 9.3.3.5 Potential security recommendations + +- Use OAuth 2.0, as specified in O-RAN Security Protocols Specifications [3], clause 4.7 to implement authorization in the R1 interface. +- Enable the SME to act as both an OAuth 2.0 resource and an OAuth 2.0 Authorization server. + +### 9.3.4 Solution #4: Secure transmission of request and response between client to authorization server, between client and resource server for R1, A1 and O2 + +#### 9.3.4.1 Background + +This solution elaborates on the possibilities to ensure that data for the below flows is secure during transmission, + +1. Between client and authorization server + - a. The client needs to send the credentials and the authorization request details which need to be secured during transmission. +2. Between client and resource server + - a. The client needs to send the access token to the authentic resource server which needs to be secured during transmission. + +#### 9.3.4.2 Solution description + +Table 9.3.4-1 use case of secure data transmission between client and authorization server + +| Use Case Stage | Evolution/Specification | <>
Related use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | 1) Transfer the data from client to authorization server securely | | +| Actors and Roles | Below are examples of HTTP clients
  • - rApp in the role of R1 Service Consumer
  • - SMO towards near RT RIC in the role of A1 consumer
  • - O-RAN assets towards O-cloud in the role of O2 consumer
| | +| Assumptions | TLS is the underlying secure protocol on which the below is built upon. | | +| Preconditions | The consumer is registered with valid client_id and client_secret
The authorization server has a valid X.509 certificate
The consumer has the trust anchor for the authorization server's X.509 certificate | | +| Begins when | The consumer needs to contact the authorization server to send an authorization request | | +| Step 1 (M) | The client authenticates to the authorization server | | +| Step 1 (M) | The client sends the request details to authorization server after successful authentication | | +| Ends when | The consumer receives the access token from the authorization server | | +| Exceptions | n/a | | +| Post Conditions | The consumer is in possession of the access token securely | | +| Traceability | n/a | | + +``` + +@startuml +hide footbox +skinparam sequenceActorBackgroundColor White +skinparam sequenceActorBorderColor Black +skinparam sequenceParticipantBackgroundColor White +skinparam sequenceParticipantBorderColor Black +skinparam sequenceArrowColor Black +skinparam sequenceLifeLineBackgroundColor White +skinparam sequenceLifeLineBorderColor Black +skinparam shadowing false +skinparam NoteBackgroundColor White +skinparam NoteBorderColor Black + +``` + +``` + +Title Secure transmission between client and authorization server +Actor "client" as client +participant "OAuth Authorization Server" as AS + +client -> AS:authenticate with client_id and client_secret +client -> AS:send authorization Request +AS -> client: send access token + +@enduml + +``` + +##### Secure transmission between client and authorization server + +![Sequence diagram showing the secure transmission between a client and an OAuth Authorization Server. The client sends an authentication request with client_id and client_secret, then sends an authorization request. The server responds by sending an access token back to the client.](f17eb6452df746bd6492315ba294d000_img.jpg) + +``` + +sequenceDiagram + actor client + participant AS as OAuth Authorization Server + client->>AS: authenticate with client_id and client_secret + client->>AS: send authorization Request + AS-->>client: send access token + +``` + +Sequence diagram showing the secure transmission between a client and an OAuth Authorization Server. The client sends an authentication request with client\_id and client\_secret, then sends an authorization request. The server responds by sending an access token back to the client. + +Figure 9.3.4-1 Transmission between client and authorization server + +``` + +@startuml +hide footbox +skinparam sequenceActorBackgroundColor White +skinparam sequenceActorBorderColor Black +skinparam sequenceParticipantBackgroundColor White +skinparam sequenceParticipantBorderColor Black +skinparam sequenceArrowColor Black +skinparam sequenceLifeLineBackgroundColor White +skinparam sequenceLifeLineBorderColor Black +skinparam shadowing false +skinparam NoteBackgroundColor White +skinparam NoteBorderColor Black + +Title Secure transmission between client and resource server +Actor "client" as client +participant "resource server" as RS + +client <-> RS:mutual authentication +client -> RS:send access token as part of API operation + +@enduml + +``` + +##### Secure transmission between client and resource server + +![Sequence diagram showing secure transmission between a client and a resource server. The client sends a 'mutual authentication' message to the resource server, and the resource server sends a 'send access token as part of API operation' message back to the client.](73269dafee299d863bdab3ef4b743124_img.jpg) + +``` + +sequenceDiagram + participant client + participant resource_server as resource server + client->>resource_server: mutual authentication + resource_server-->>client: send access token as part of API operation + +``` + +Sequence diagram showing secure transmission between a client and a resource server. The client sends a 'mutual authentication' message to the resource server, and the resource server sends a 'send access token as part of API operation' message back to the client. + +Figure 9.3.4-2 Transmission between client and resource server + +##### 9.3.4.2.1 Authentication methods between client, authorization server and resource server + +The solutions below are various options to transfer the information securely between the O-RAN OAuth clients and the various servers in the interaction including the authorization server and the various O-RAN resource servers. + +Below is a summary: + +Table 9.3.4-2 Authentication methods + +| OAuth token end point authentication method | Reference | Short description | +|---------------------------------------------|--------------------------|--------------------------------------------------------------------------------------------------------------------------------| +| Tls_client_auth | RFC 8705[i.6] | Usage of certificates for both client and server authentication. Usage of certificate hash for certificate bound access tokens | +| private_key_JWT (with JWE) | RFC 8705[i.6] | Usage of certificates for both integrity and confidentiality protection(encryption) | +| private_key_jwt | OpenID foundation [i.21] | Usage of certificates for integrity protection | +| Client_secret_jwt | OpenID foundation [i.21] | Usage of shared secret for example client_secret for integrity protection | +| Client_secret_basic | RFC 7591[i.22] | Client_id and client_secret transmission in the header | +| Client_secret_post | RFC 7591[i.22] | Client_id and client_secret transmission in the payload | +| Self_signed_tls_client_auth | RFC 8705[i.6] | Usage of client side self signed certificates in mutual authentication | + +Below are the details of the methods explained above + +- 1) Tls\_client\_auth + - a. Part of RFC 8705. + - b. Mutual authentication of both client and server. Here certificates are issued by a certificate authority. Also supports token binding. + - c. For certificate bound access tokens every party proves that they are in possession of their private key. + - d. Who is in possession of the private key used to establish the connection can use the access token (puts the hash of the certificate(cnf) that has been used). + +![Figure 9.3.4-3: tls_client_oauth method diagram. A client and an OAuth server establish a Mutual TLS connection. The client then sends a request to a Resource server, also using Mutual TLS. The request body contains: alg: RS256, client_id: abc123, Content-Type: application/x-www-form-urlencoded, and a signature.](94220bb4f68889783b714d2c1e688efd_img.jpg) + +Figure 9.3.4-3: tls\_client\_oauth method diagram. A client and an OAuth server establish a Mutual TLS connection. The client then sends a request to a Resource server, also using Mutual TLS. The request body contains: alg: RS256, client\_id: abc123, Content-Type: application/x-www-form-urlencoded, and a signature. + +Figure 9.3.4-3 - tls\_client\_oauth method + +###### 2) private\_key\_jwt(with JWE) + +- Part of OpenID foundation specification. +- Public and private key is used to sign and encrypt the JWT token using asymmetric cryptography. +- Contents of the message cannot be seen as they are encrypted. + +![Figure 9.3.4-4: Private_key_jwt with JWE method diagram. A client sends a POST request to an OAuth server. The request body is a JWT token with a header and a body containing 'Post /token' and 'Client_assertion_URI=, client_assertion_'. The JWT token structure is detailed as: Header, Encrypted key, Initialisation vector, Ciphered text (encrypted JWS), and Authentication tag.](5f19af628e407fc47cc229cb28b0c74d_img.jpg) + +Figure 9.3.4-4: Private\_key\_jwt with JWE method diagram. A client sends a POST request to an OAuth server. The request body is a JWT token with a header and a body containing 'Post /token' and 'Client\_assertion\_URI=, client\_assertion\_'. The JWT token structure is detailed as: Header, Encrypted key, Initialisation vector, Ciphered text (encrypted JWS), and Authentication tag. + +Figure 9.3.4-4 Private\_key\_jwt with JWE method + +###### 3) private\_key\_jwt + +- Part of OpenID foundation specification. +- The client\_id and client\_secret is part of the JWT token which is integrity protected. The JWT is a string which is attached as a client assertion. Here we AVOID putting the secret in message, instead in the JWT token. +- Confidential client create JSON Web Token along with the public and private key. Hence structure of the JWT is the header, body and the Signature. Hence JWS client has the private key and shares the public key to the authorization server for validation of the request. Hence the contents of the message can be seen but secure from manipulation. + +![Figure 9.3.4-5: Private_key_jwt method diagram. A client sends a POST request to an OAuth server. The request body is a JWT token with a header and a body containing 'Post /token' and 'Client_assertion_type=, client_assertion_'. The JWT token structure is detailed as: Header, Body (containing client_id: abc123, response_type: code, state: abc, redirect_uri: registered-redirect-uri), and Signature.](6c5d2fe2435998deda747107ff9b3418_img.jpg) + +Figure 9.3.4-5: Private\_key\_jwt method diagram. A client sends a POST request to an OAuth server. The request body is a JWT token with a header and a body containing 'Post /token' and 'Client\_assertion\_type=, client\_assertion\_'. The JWT token structure is detailed as: Header, Body (containing client\_id: abc123, response\_type: code, state: abc, redirect\_uri: registered-redirect-uri), and Signature. + +Figure 9.3.4-5 Private\_key\_jwt method + +###### 4) Client\_secret\_jwt + +- a. Part of OpenID foundation specification. +- b. Client\_secret\_JWT - client\_id and client\_secret in the JWT token which is integrity protected with a shared secret key (client\_secret known to both parties) using HMAC. The JWT is a string which is attached as a client assertion. Here we AVOID putting the secret in message. Instead in the JWT token which is with a MAC (hash function+Secret). + +![Diagram of Client_secret_jwt method showing a client sending a POST request to an OAuth server. The request body contains a client assertion JWT. The JWT structure is shown as a box with three parts: Header (alg: RS256), Body (client_id: abc123, response_type: code, state: abc, redirect_uri: registered-), and MAC.](721fd8bad03ea911b51744d701b1a4aa_img.jpg) + +``` + +graph LR + client[client] -- "Post /token" --> OAuthServer[OAuth server] + subgraph RequestBody [Body] + ClientAssertion[Client_assertion_type=, client_assertion_] + end + subgraph JWTToken [JWT Token] + Header[Header +alg: RS256] + Body[Body +client_id: abc123 +response_type: code +state: abc +redirect_uri: registered-] + MAC[MAC] + end + ClientAssertion --> JWTToken + +``` + +Diagram of Client\_secret\_jwt method showing a client sending a POST request to an OAuth server. The request body contains a client assertion JWT. The JWT structure is shown as a box with three parts: Header (alg: RS256), Body (client\_id: abc123, response\_type: code, state: abc, redirect\_uri: registered-), and MAC. + +Figure 9.3.4-6 Client\_secret\_jwt method + +###### 5) Client\_secret\_basic + +- a. client\_id and client\_secret in the header of the message. +- b. Defined in RFC 7591. + +![Diagram of Client_secret_basic method showing a client sending a request to an OAuth server. The request header contains the client_id and client_secret encoded in Basic authentication.](32c18302ce5dfed581ce2383200fe9f3_img.jpg) + +``` + +graph LR + client[client] --> OAuthServer[OAuth server] + subgraph RequestHeader [Header] + AuthHeader["(Authorization:Basic-Base64encoding)"] + end + subgraph RequestBody [Body] + end + +``` + +Diagram of Client\_secret\_basic method showing a client sending a request to an OAuth server. The request header contains the client\_id and client\_secret encoded in Basic authentication. + +Figure 9.3.4-7 Client\_secret\_basic method + +###### 6) Client\_secret\_post + +- a. client\_id and client\_secret in the body of the message. +- b. Defined in RFC 7591. + +![Diagram of Client_secret_post method showing a client sending a request to an OAuth server. The request body contains the client_id and client_secret.](3eca327934fcf4921aec9541163a1e4a_img.jpg) + +``` + +graph LR + client[client] --> OAuthServer[OAuth server] + subgraph RequestHeader [Header] + end + subgraph RequestBody [Body] + BodyContent[""] + end + +``` + +Diagram of Client\_secret\_post method showing a client sending a request to an OAuth server. The request body contains the client\_id and client\_secret. + +Figure 9.3.4-8 Client\_secret\_post method + +###### 7) Self\_signed\_tls\_client\_auth + +- a. RFC 8705. +- b. Mutual authentication using self signed certificates. Here certificate is created by self signing. + +![Diagram illustrating the Self_signed_tls_client_auth method. A client (labeled 'Self signed') communicates with an OAuth server and a Resource server via Mutual TLS. The client sends a token to the Resource server. The token structure is shown as: { 'alg': 'RS256', 'client_id': 'abc123', 'cnf': { 'X256': '', 'signature' } }.](359171a069930c765ab1263b2a654639_img.jpg) + +Diagram illustrating the Self\_signed\_tls\_client\_auth method. A client (labeled 'Self signed') communicates with an OAuth server and a Resource server via Mutual TLS. The client sends a token to the Resource server. The token structure is shown as: { 'alg': 'RS256', 'client\_id': 'abc123', 'cnf': { 'X256': '', 'signature' } }. + +Figure 9.3.4-9 Self\_signed\_tls\_client\_auth method + +#### 9.3.4.3 Impacts on existing O-RAN architecture elements and interfaces + +R1 client, A1 client and the O2 client needs to choose the authentication method from the options explained above depending on the client and authorization server capabilities: + +#### 9.3.4.4 Solution evaluation + +There is a need to support secure transmission of request and response between client and authorization server, between client to resource server. Below is the order of preference of various methods explained above in the order of most preferred to least preferred depending on the authorization server capabilities as well as the security level preferred. + +Table 9.3.4-3 Authentication method preferences + +| OAuth token end point authentication method | Evaluation | +|---------------------------------------------|------------------| +| Tls_client_auth | Highly preferred | +| private_key_JWT(with JWE) | Preferred | +| private_key_jwt | Preferred | +| Client_secret_jwt | Preferred | +| Client_secret_basic | Preferred | +| Client_secret_post | Preferred | +| Self_signed_tls_client_auth | Least preferred | + +# --- 10 Study and Recommendation an O-RAN Authorization Server Architecture + +Editor's note: This section will do a study and recommendation on an authorization server architecture to overlay on the O-RAN architecture. + +# --- 11 Conclusion + +Editor's note : This clause will provide the summary for the TR and mapping tables the key issues and solutions and it will submit the recommendations to WG1 for O-RAN Authorization server. + +# --- Annex:Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|------------------------------------------------------------------------------------------| +| 2023.05.10 | 00.00.01 | Initial TS skeleton | +| 2023.08.23 | 00.00.02 | Updated the scope and reference for the TR | +| 2023.10.16 | 00.00.03 | Updated the TR based on CR approved in OAuth 2.0 meeting for Nov train | +| 2023.10.24 | 00.00.04 | Updated the TR based on CR approved during O-RAN F2F phoenix meeting | +| 2023.11.21 | 01.00 | Final version 01.00 | +| 2024.02.07 | 01.00.01 | Updated the TR based on CR approved for OAuth 2.0 TR WI meeting in Dec 2023 and Jan 2024 | +| 2024.03.05 | 01.00.02 | Updated the TR based on CR approved for OAuth 2.0 TR WI meeting in Feb 2024 | +| 2024.06.26 | 02.00.01 | Updated the TR based on CR approved for OAuth 2.0 TR WI meeting from April to June 2024 | +| 2024.07.05 | 02.00.02 | Updated the TR based on the review comments during July 2024 plenary approvals | +| 2024.07.26 | 02.00.03 | Updated the TR based on the review comments during July 2024 WG11 voting | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/029fa62d9300e01961ef344254850b13_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/029fa62d9300e01961ef344254850b13_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0e47ef6d12c53c5950d611cc46cbd53d85dccd30 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/029fa62d9300e01961ef344254850b13_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd1d7a495dd36743cb28ca6388e8af181a6e1d5e21f1e9d4ae190efb04d19033 +size 20575 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/18eeb780314d33cfa2fd9be2d8d9268d_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/18eeb780314d33cfa2fd9be2d8d9268d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..449a0f9e6017cfc574f2bec9904176df2e99c77b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/18eeb780314d33cfa2fd9be2d8d9268d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a438ea0ed722c92a18b391b98a949fe4660683d223b57fb21a6940e7595e94ce +size 4569 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/1c99badc8bc8417c196a2b65d28ed25b_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/1c99badc8bc8417c196a2b65d28ed25b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3a5e5d3f72de34a942488a3c04fe0926cafeab27 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/1c99badc8bc8417c196a2b65d28ed25b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f956dcb285ac2762d3dc65d7ba58fc002e542b1cbeb8baa7b325a4e0be6ec290 +size 104272 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/286b26b15126a3ba268b5681f517d12b_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/286b26b15126a3ba268b5681f517d12b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b00837ce04cba02ed80936562a6f67ba2d0ea3f5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/286b26b15126a3ba268b5681f517d12b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a97ae7743c75cfc2809ab46306087b4d32c68d236dea02067b7b28bf466bed91 +size 79535 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/2aec8738d5049d3aa40c1fd8f956b7f6_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/2aec8738d5049d3aa40c1fd8f956b7f6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..07345ab54e04cdd8a94d311e7f94002048a38d2f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/2aec8738d5049d3aa40c1fd8f956b7f6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e1c48dbc85dd17bb19455266c6247f3bbc2f4905d019e051b4d1f45bf6775b7e +size 47105 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/2b77b79aca6255c5539f79ed016c91d4_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/2b77b79aca6255c5539f79ed016c91d4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..15a2563d6e05f46fa166856b3b8a60dd231e93a2 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/2b77b79aca6255c5539f79ed016c91d4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ba3def08f001bc93fd1e9b4f99fc2e314ce84a9ee6fd7a6257f43ee01a7538f6 +size 15341 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/676c91b64382565d972aaef1aeb60f35_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/676c91b64382565d972aaef1aeb60f35_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..17e9aeebaaf53d6100482d20b8dbdbd363ecb52b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/676c91b64382565d972aaef1aeb60f35_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b0f20f21b66dfe1b951c86e5ef199d9677e37716f224c6a93c40e9a0a2979aa5 +size 4549 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/693da3ba03e0bad52e214d32d001592d_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/693da3ba03e0bad52e214d32d001592d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..40ad253cf45f2af5730a5c495efa97d1d277058a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/693da3ba03e0bad52e214d32d001592d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:765d67fb98d12f2771ad024dfd0eab37f8a1c0bb686790b3e75b52213537a8e0 +size 48302 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/b7309ad0714cf8617b76a86886fd6f52_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/b7309ad0714cf8617b76a86886fd6f52_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..50d19f568b6453a2320b6f8261e19d7f06a0c025 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/b7309ad0714cf8617b76a86886fd6f52_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c6c51568cf0a2c1bdbbf681ad8402225ca0a133226eb7c4693f05fd8b9a66451 +size 109611 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/f11c22832f1b704bc78d6534ae671707_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/f11c22832f1b704bc78d6534ae671707_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..177351ab5ef5b4ac9c28fee6595310aa3c7c929b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/f11c22832f1b704bc78d6534ae671707_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:018b00f084ea7ed43fdf85c27fd850157cebe839c4f8c5fa879c60df49e9c2a5 +size 4512 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/ff987744738e233e788c537647268a9e_img.jpg b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/ff987744738e233e788c537647268a9e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7ce84f123a24b19400bc0a8bc4429dbefe277da1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/ff987744738e233e788c537647268a9e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2849c5f57efd4d7acea57a957a9f14159527bcbcf3478462cf1f2d5d5dd54e6a +size 16952 diff --git a/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/raw.md b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..4f63c5200b775598e849a74ec82d4df41b86ff82 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00/raw.md @@ -0,0 +1,1962 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****Study on Security Log Management** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----| +| Contents..... | 2 | +| List of figures ..... | 5 | +| List of tables ..... | 5 | +| Foreword ..... | 6 | +| Modal verbs terminology ..... | 6 | +| Introduction ..... | 6 | +| 1 Scope..... | 6 | +| 2 References..... | 6 | +| 2.1 Informative references..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 9 | +| 3.1 Terms..... | 9 | +| 3.2 Abbreviations ..... | 10 | +| 4 Security Log Management background, concepts and assumptions..... | 12 | +| 4.1 Introduction ..... | 12 | +| 4.2 Definition of Event Sources ..... | 14 | +| 4.3 Security Log Data Lifecycle Management..... | 15 | +| 5 Key Issues ..... | 15 | +| 5.1 Introduction ..... | 15 | +| 5.2 Security logs contents..... | 15 | +| 5.2.1 Key Issue SLC#1: Logging all security related activity and events..... | 15 | +| 5.2.2 Key Issue SLC#2: Log authentication attempts ..... | 19 | +| 5.2.3 Key Issue SLC#3: Log encryption configuration information ..... | 19 | +| 5.2.4 Key Issue SLC#4: Logging accesses to personal data ..... | 20 | +| 5.2.5 Key Issue SLC#5: Logging events related to the Master Clock..... | 20 | +| 5.2.6 Key Issue SLC#6: Logging details of xApps ..... | 21 | +| 5.2.7 Key Issue SLC#7: Logging details of rApps..... | 21 | +| 5.2.8 Key Issue SLC#8: Logging details of VNF/CNF..... | 21 | +| 5.2.9 Key Issue SLC#9: Logging information of dynamically loaded libraries..... | 21 | +| 5.2.10 Key Issue SLC#10: Logging accesses to ML training data..... | 21 | +| 5.2.11 Key Issue SLC#11: No differentiation between M2M and human interfaces ..... | 21 | +| 5.2.12 Key Issue SLC#12: Logging the identity of the person or process that originated the request,
response, or the entity that originated the log message in the metadata..... | 21 | +| 5.2.13 Key Issue SLC#13: Maintaining unique system references in the logs ..... | 22 | +| 5.2.14 Key Issue SLC#14: Synchronization of logs using common time sources..... | 22 | +| 5.2.15 Key issue SLC#15: Emergency calls related logs ..... | 23 | +| 5.2.16 Key issue SLC#16: Logging details of O-Cloud..... | 23 | +| 5.3 Security logs transfer mechanisms..... | 24 | +| 5.3.1 Introduction ..... | 24 | +| 5.3.2 Key Issue SLTM#1: Secure storage at rest ..... | 24 | +| 5.3.3 Key Issue SLTM#2: Study security logging best practices of ONAP Project ..... | 25 | +| 5.3.4 Key Issue SLTM#3: Secure transfer protocols..... | 25 | +| 5.3.5 Key Issue SLTM#4: Availability of logging ..... | 25 | +| 5.4 Security logs formats..... | 27 | +| 5.4.1 Key Issue SLF#1: Standardized logging metadata to support security analytics..... | 27 | +| 5.4.2 Key Issue SLF#2: Logging the field “date/time” in the metadata of the security audit logs. .... | 28 | +| 5.4.3 Key Issue SLF#3: Standardized logging format ..... | 28 | +| 5.5 Log management security framework..... | 28 | +| 6 Mitigations and Solutions ..... | 31 | +| 6.1 Introduction ..... | 31 | + +| | | | +|--------|----------------------------------------------------------------------------------------|----| +| 6.2 | Solution#1: Trusted environment for cluster node..... | 31 | +| 6.2.1 | Introduction ..... | 31 | +| 6.2.2 | Solution details ..... | 31 | +| 6.2.3 | Evaluation..... | 32 | +| 6.3 | Solution #2: Trusted environment for data repository ..... | 32 | +| 6.3.1 | Introduction ..... | 32 | +| 6.3.2 | Solution details ..... | 32 | +| 6.3.3 | Evaluation..... | 34 | +| 6.4 | Solution #3: Solution on log-data life cycle management ..... | 34 | +| 6.4.1 | Introduction ..... | 34 | +| 6.4.2 | Solution details ..... | 34 | +| 6.4.3 | Evaluation..... | 35 | +| 6.5 | Solution #4: Solution on (D)DoS to log-data management ..... | 35 | +| 6.5.1 | Introduction ..... | 35 | +| 6.5.2 | Solution details ..... | 35 | +| 6.5.3 | Evaluation..... | 35 | +| 6.6 | Solution #5: Solution on authenticated time stamping..... | 35 | +| 6.6.1 | Introduction ..... | 35 | +| 6.6.2 | Solution details ..... | 35 | +| 6.6.3 | Evaluation..... | 36 | +| 6.7 | Solution #6: Solution on due diligence and log-data auditing ..... | 36 | +| 6.7.1 | Introduction ..... | 36 | +| 6.7.2 | Solution details ..... | 36 | +| 6.7.3 | Evaluation..... | 39 | +| 6.8 | Solution #7: Log format ..... | 40 | +| 6.8.1 | Introduction ..... | 40 | +| 6.8.2 | Solution details ..... | 40 | +| 6.8.3 | Evaluation..... | 40 | +| 6.9 | Solution #8: Log content: key fields for all security log events..... | 41 | +| 6.9.1 | Introduction ..... | 41 | +| 6.9.2 | Solutions ..... | 41 | +| 6.9.3 | Evaluation..... | 41 | +| 6.10 | Solution #9: Secure storage at rest ..... | 42 | +| 6.10.1 | Introduction ..... | 42 | +| 6.10.2 | Solution details ..... | 42 | +| 6.10.3 | Evaluation..... | 42 | +| 6.11 | Solution #10: Secure transfer of logs ..... | 42 | +| 6.11.1 | Introduction ..... | 42 | +| 6.11.2 | Solution details ..... | 42 | +| 6.11.3 | Evaluation..... | 43 | +| 6.12 | Solution #11: Logging in O-RAN AI/ML systems..... | 43 | +| 6.12.1 | Introduction ..... | 43 | +| 6.12.2 | Solution details ..... | 43 | +| 6.12.3 | Evaluation..... | 45 | +| 6.13 | Solution #12: Solution on preventing the tampering of log-Data ..... | 45 | +| 6.13.1 | Introduction ..... | 45 | +| 6.13.2 | Solution details ..... | 46 | +| 6.13.3 | Evaluation..... | 46 | +| 6.14 | Solution #13: Security-related activities and events to be logged ..... | 46 | +| 6.14.1 | Introduction ..... | 46 | +| 6.14.2 | Solution details ..... | 47 | +| 6.14.3 | Evaluation..... | 49 | +| 6.15 | Solution #14: Log content: solution for harmonizing timestamps ..... | 49 | +| 6.15.1 | Introduction ..... | 49 | +| 6.15.2 | Solutions ..... | 49 | +| 6.15.3 | Evaluation..... | 50 | +| 6.16 | Solution #15: Solution on Logs Using Common Time Sources ..... | 50 | +| 6.16.1 | Introduction ..... | 50 | +| 6.16.2 | Solution Details ..... | 50 | +| 6.16.3 | Evaluation..... | 51 | +| 6.17 | Solution #16: Availability of Logging: Solution for ensuring logging reliability ..... | 51 | + +| | | | +|------------------------------------------------------|-------------------------------------------------|----| +| 6.17.1 | Introduction ..... | 51 | +| 6.17.2 | Solutions ..... | 51 | +| 6.17.3 | Evaluation ..... | 51 | +| 7 | Conclusions ..... | 51 | +| 7.1 | Key Issue Solution Mapping ..... | 51 | +| 7.1.1 | Security logs contents ..... | 51 | +| 7.1.2 | Security logs transfer mechanisms ..... | 53 | +| 7.1.3 | Security logs formats ..... | 53 | +| 7.1.4 | Log Management Security Framework ..... | 53 | +| 7.2 | Alignment to other studies ..... | 54 | +| 7.2.1 | Application Lifecycle Management Security ..... | 54 | +| 8 | Recommendations ..... | 55 | +| Annex: Change history/Change request (history) ..... | | 56 | + +# List of figures + +| | | +|------------------------------------------------------------------|----| +| Figure 4.1-1 Log-management architecture ..... | 13 | +| Figure 4.1-2 Definition of Asset ..... | 14 | +| Figure 5.3-1 possible configuration for log availability ..... | 26 | +| Figure 5.4-1 Security Event Entry ..... | 27 | +| Figure 6.8-1 Log Normalization ..... | 40 | +| Figure 6.8-2 Log message structure and example log message ..... | 40 | +| Figure 6.12-1 - O-RAN AI/ML Workflow [i.43] ..... | 44 | +| Figure 6.15-1 Example of timestamp-adaptation in the SIEM ..... | 50 | +| Figure 8-1 An example Security Log Management Schema ..... | 56 | + +# List of tables + +| | | +|--------------------------------------------------------------------------------------------|----| +| Table 4.2-1: Cloud Services vs. Event Sources (Overview) ..... | 14 | +| Table 6.9-1 Log Content ..... | 41 | +| Table 6.9-2 Key fields ..... | 41 | +| Table 6.12-1 - Pipeline components in reference [i.42] compared to reference [i.43]. ..... | 43 | +| Table 6.14-1 Event categories to be logged ..... | 47 | +| Table 7.1-1 Key Issue Solution mapping for Security logs contents ..... | 51 | +| Table 7.1-2 Key Issue Solution mapping for Security logs transfer mechanisms ..... | 53 | +| Table 7.1-3 Key Issue Solution mapping for Security logs formats ..... | 53 | +| Table 7.1-4 Key Issue Solution mapping for Log Management Security Framework ..... | 53 | +| Table 7.2-1 - Application LCM Logging Events ..... | 54 | + +# --- Foreword + +This Technical Report (TR) has been produced by the O-RAN Alliance. + +--- + +## Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Introduction + +This Technical Report addresses the Security Log Management across the entire O-RAN architecture. + +Security Log Management has not been part of O-RAN specifications yet, although the term FCAPS (Fault, Configuration, Accounting, Performance, Security) has been used in several documents. Specifically, the following definitions are still to be specified in O-RAN: + +- 1 Security logs contents (payload) +- 2 Security logs transfer mechanisms +- 3 Security logs formats/schemas + +Security mechanisms applied to protection of the security logs at rest and in transit, i.e. confidentiality, integrity and access control mechanisms are considered. + +A major goal of the work item related to this Technical Report is to define requirements and solutions that comply with industry standards for Security Log Management. + +Another goal of the work item related to this Technical Report is to provide guidance for the implementation of security monitoring use cases to O-RAN infrastructure operators. + +--- + +# 1 Scope + +The present document considers the security log management as far as it applies to entities defined in the O-RAN architecture. + +Taking into consideration the threats and risks identified in O-RAN Security Threat Modeling and Risk Assessment Technical Report [i.1], the study analyses a list of key issues on Security logs contents (payload), Security logs transfer mechanisms and Security logs formats/schemas and proposes solutions in order to derive security requirements, intended to be part of O-RAN Security related Specifications. + +--- + +# 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [i.1] O-RAN ALLIANCE TR: “O-RAN Security Threat Modeling and Risk Assessment” +- [i.2] O-RAN ALLIANCE TS: “O-RAN Security Requirements and Controls Specifications” +- [i.3] O-RAN ALLIANCE TS: “O-RAN-Security-Protocols-Specifications” +- [i.4] Kubernetes Logging: A Comprehensive Guide For Beginners: +- [i.5] Red Hat - Understanding the logging subsystem for Red Hat OpenShift: +- [i.6] IBM - Audit logging adoption guide: +- [i.7] ETSI GR NFV 003 V1.5.1 (2020-01), Network Functions Virtualisation (NFV); Terminology for Main Concepts in NFV +- [i.8] NIST: Role-based Access Control (RBAC), +- [i.9] Kubernetes: Logging Architecture: +- [i.10] Open Web Application Security Project (OWASP), +- [i.11] OWASP Logging Guide, [https://owasp.org/www-pdf-archive/OWASP\\_Logging\\_Guide.pdf](https://owasp.org/www-pdf-archive/OWASP_Logging_Guide.pdf) +- [i.12] NIST Special Publication 800-145, The NIST Definition of Cloud Computing +- [i.13] ISO/IEC 17789:2014, Cloud Computing - Reference Architecture +- [i.14] NIST Special Publication 800-92, Guide to Computer Security Log Management; +- [i.15] OSI Reference Model, ISO Standard 7498-1 +- [i.16] IETF TCP/IP Protocol Suite; +- [i.17] Guide to Storage Encryption Technologies for End User Devices, NIST SP800-111 +- [i.18] ENISA – NFV Security in 5G - Challenges and Best Practices; +- [i.19] Red Hat, Viewing system event information in an OpenShift Container Platform cluster; +- [i.20] Kubernetes Monitoring, Logging, and Debugging; +- [i.21] Docker - Audit logs; +- [i.22] VMware - Audit Logging; +- [i.23] OpenStack - Monitoring and logging; +- [i.24] The MITRE Corporation, “MITRE ATT&CK® Containers Matrix”, Accessed on 03 AUG 2022, + +- [i.25] Linux Foundation, “ONAP Documentation”, Accessed on 03 AUG 2022, + +- [i.26] 3GPP, TS 33.117 v17.0.0, Catalogue of general security assurance requirements +- [i.27] OWASP Foundation, OWASP Cheat Sheet Series, “Logging Cheat Sheet” +- [i.28] “Security Logs Standard: NOCH IMMER EINE UNGEKLÄRTE FRAGE”: + +- [i.29] O-RAN ALLIANCE TS, “O-RAN Architecture Description” +- [i.30] O-RAN ALLIANCE TR, “WG11 Study on Security for Application Lifecycle Management” +- [i.31] (EU) 2016/679: General Data Protection Regulation: +- [i.32] O-RAN ALLIANCE TS, “WG4 Management Plane Specification” +- [i.33] 3GPP, TS 28.537 v17.3.0, Management and orchestration; Management capabilities +- [i.34] O-RAN ALLIANCE TS, “O-RAN Operations and Maintenance Interface Specification” +- [i.35] ONAP, Security Logging Best Practice, + +- [i.36] IETF RFC 5424, The Syslog Protocol +- [i.37] IETF RFC 5425, Transport Layer Security (TLS) Transport Mapping for Syslog +- [i.38] NIST Special Publication 800-162, “Guide to ABAC Definition and Considerations”, January 2014, + +- [i.39] Log normalization: Log Normalization - Glossary | CSRC (nist.gov) +- [i.40] O-RAN ALLIANCE TR, “O-RAN WG1 Use Cases Analysis Report” +- [i.41] O-RAN ALLIANCE, “Discussions on the AI/ML in O-RAN feature in the Near-RT RIC architecture”, +December 6, 2022. +- [i.42] O-RAN ALLIANCE TR, “O-RAN WG11 WI AI/ML Security Adversarial Machine Learning (AML) +Threat Analysis and Remediation”, January 2023. +[https://oranalliance.atlassian.net/wiki/download/attachments/2537881609/WI\\_MLSec\\_SecAnalysisDoc\\_v1.docx](https://oranalliance.atlassian.net/wiki/download/attachments/2537881609/WI_MLSec_SecAnalysisDoc_v1.docx) +- [i.43] O-RAN ALLIANCE TR, “O-RAN WG2 AI/ML workflow description and requirements” + +- [i.44] ISO/IEC 27000:2018, Information technology - Security techniques - Information security management systems - Overview and vocabulary +- [i.45] O-RAN ALLIANCE TS, “O-RAN Security Test Specifications” +- [i.46] IETF RFC 3339, Date and Time on the Internet: Timestamps +- [i.47] IEEE 1588-2019, IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems +- [i.48] ISO 8601, Date and time format +- [i.49] Cypress: How To Prevent Data Tampering In Your Business; + + +- [i.50] Security log management and logging best practices | TechTarget: + +- [i.51] RELP output module, +- [i.52] RELP input module, +- [i.53] IETF RFC 3080, The Blocks Extensible Exchange Protocol Core +- [i.54] IETF RFC 3195, Reliable Delivery for syslog +- [i.55] NIST Special Publication 800-34, “Contingency Planning Guide for Federal Information Systems”, + +- [i.56] NIST Special Publication 800-61, “Computer Security Incident Handling Guide”, August 2012, + + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms and definitions apply. + +### **Audit Records** + +“Audit records contain security event information such as successful and failed authentication attempts, file accesses, security policy changes, account changes (e.g., account creation and deletion, account privilege assignment), and use of privileges. OSs typically permit system administrators to specify which types of events should be audited and whether successful and/or failed attempts to perform certain actions should be logged.” [i.14] + +### **Information Security Event** + +“Identified occurrence of a system, service or network state indicating a possible breach of information security policy or failure of controls, or a previously unknown situation that can be security relevant” [i.44] + +### **Information Security Incident** + +“Single or a series of unwanted or unexpected information security events that have a significant probability of compromising business operations and threatening information security.” [i.44] + +### **Log** + +“A log is a record of the events occurring within an organization’s systems and networks. Logs are composed of log entries; each entry contains information related to a specific event that has occurred within a system or network. Logs have evolved to contain information related to many different types of events occurring within networks and systems. Within an organization, many logs contain records related to computer security; common examples of these computer security logs are audit logs that track user authentication attempts and security device logs that record possible attacks.” [i.14] + +### **Log Data** + +The term log data is referring to a log entry as defined by the guide to computer security log management: “A log is a record of the events occurring within an organization’s systems and networks. Logs are composed of log entries: each entry contains information related to a specific event that has occurred within a system or network.” [i.14]. + +### **Log Preservation** + +“Logs often need to be preserved to meet legal or regulatory requirements. Log preservation is keeping logs that normally would be discarded, because they contain records of activity of particular interest. Log preservation is typically performed in support of incident handling or investigations.” [i.14] + +### Log Retention + +The term ‘log retention’ refers mainly to the archiving of log data. The “Log archival is retaining logs for an extended period of time, typically on removable media, a storage area network (SAN), or a specialized log archival appliance or server.” [i.14] The “old logs are archived for the appropriate length of time and then destroyed when no longer needed, in compliance with the organization’s logging, data retention, and media sanitization policies.” [i.14] + +### Log Rotation + +“Log rotation is closing a log file and opening a new log file when the first file is considered to be complete. Log rotation is typically performed according to a schedule (e.g., hourly, daily, weekly) or when a log file reaches a certain size. The primary benefits of log rotation are preserving log entries and keeping the size of log files manageable. When a log file is rotated, the preserved log file can be compressed to save space.” [i.14] + +### Perimeter Security + +The Perimeter refers to the boundary line between something that is trusted and some other that is seen as untrusted. This boundary line can be singular, but it can also span a surface/area/environment. In any case, this boundary line and the surface/area/environment is secured by security controls in place which is referring further to as perimeter security. The fact that this boundary line can be adapted according to the product makes it possible to define the perimeter security on the edge of a product, on the edge of a device, or it can be defined on service and application level. + +### Storage Media + +The term storage media refers to the physical storage of electronic data. It can be any technology to place the electronic data (e.g., hard drives, SSDs, DVDs, and others). The storage media can be internal or external to a system. + +### System Events + +“System events are operational actions performed by OS components, such as shutting down the system or starting a service. Typically, failed events and the most significant successful events are logged, but many OSs permit administrators to specify which types of events will be logged. The details logged for each event also vary widely; each event is usually timestamped, and other supporting information could include event, status, and error codes; service name; and user or system account associated with an event.” [i.14] + +## 3.2 Abbreviations + +For the purposes of the present document, the following abbreviations apply. + +| | | +|----------|-------------------------------------------------------------------------| +| ABAC | Attribute Based Access Control | +| AC | Access Control | +| AES-CMAC | Advanced Encryption Standard - Cipher-based Message Authentication Code | +| AI/ML | Artificial Intelligence/Machine Learning | +| API | Application Programming Interface | +| CP | Control Plane | +| CPU | Central Processing Unit | +| (D)DoS | (Distributed) Denial of Service | +| DLP | Data Loss Prevention | +| DTLS | Datagram Transport Layer Security | +| DVD | Digital Versatile Disc | +| E2SM | E2 Service Model | + +| | | +|-------------|---------------------------------------------------------| +| eNB | e NodeB (applies to LTE) | +| FCAPS | Fault, Configuration, Accounting, Performance, Security | +| FM | Fault Management | +| GDPR | General Data Protection Regulation | +| gNB | g NodeB (applies to NR) | +| GNSS | Global Navigation Satellite System | +| GUI | Graphical User Interface | +| HDD | Hard Drive Disk | +| HW | Hardware | +| IaaS | Infrastructure as a service | +| IDS | Intrusion Detection System | +| IP | Internet Protocol | +| IPS | Intrusion Prevention System | +| IPsec | Internet Protocol Security | +| JWS | JSON Web Signature | +| JWT | JSON Web Token | +| LCM | Life-Cycle Management | +| MEC | Multi-access Edge Computing | +| MIMO | Multiple Input Multiple Output | +| Near-RT RIC | Near-real-time RAN Intelligent Controller | +| NIB | Network Information Base | +| Non-RT RIC | Non-real-time RAN Intelligent Controller | +| NPE | non-person entity | +| NTP | Network Time Protocol | +| NTPv4 | Network Time Protocol version 4 | +| NTS | Network Time Security | +| O-CU | O-RAN Central Unit | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| OS | Operating System | +| OSI | Open Systems Interconnection | +| OWASP | Open Web Application Security Project | +| PaaS | Platform as a service | +| PII | Personally Identifiable Information | +| PM | Performance Management | +| PNF | Physical Network Function | +| PTP | Precision Time Protocol | +| QoE | Quality of Experience | +| QoS | Quality of Service | +| RAN | Radio Access Network | + +| | | +|---------|------------------------------------------------| +| RBAC | Role Based Access Control | +| RB-RBAC | Rule Based RBAC | +| RELP | Reliable Event Logging Protocol | +| RIC | RAN Intelligent Controller | +| R-NIB | Radio-Network Information Base | +| RRM | Radio Resource Management | +| SAN | Storage Area Network | +| SaaS | Software as a service | +| SBA | Service Based Architecture | +| SDL | Shared Data Layer | +| SIEM | Security Information and Event Management | +| SMO | Service Management and Orchestration | +| SOC | Security Operations Center | +| (S)RAM | (Static) Random Access Memory | +| SSD | Solid State Disk | +| SW | Software | +| TCP/IP | Transport Control Protocol / Internet Protocol | +| TLS | Transport Layer Security | +| UE | User Equipment | +| UE-NIB | UE-Network Information Base | +| UP | User Plane | +| UTC | Universal Time Coordinated | +| VM | Virtual Machine | +| VNFC | Virtual Network Function Component | + +# 4 Security Log Management background, concepts and assumptions + +## 4.1 Introduction + +Figure 4.1-1 depicts one possible log-management architecture for VM-based or containerized implementation and introduction of SIEM. SIEM is out of scope for the O-RAN Alliance and is not specified by the O-RAN Alliance. The figure attempts to describe the log-management architecture on an abstract level, independent to whether the implementation is physical, VM-based or containerized. The figure has been created based on different sources (see [i.4], [i.5], [i.6], and [i.9]). + +![Figure 4.1-1 Log-management architecture diagram. The diagram shows a Cluster-Node (light blue box) containing a Trusted-Environment (dashed red box). Inside the Trusted-Environment, there is a Logging-VNFC (purple box) containing three Log-Agents (blue boxes) and a Log Collector (blue box) with a Scheduler and Context-based Aggregation. Below the Logging-VNFC is a Platform (white box) with OS-level-audit.log (orange box). To the left of the Logging-VNFC is an App-VNFC (purple box) with App-audit.log (orange box) and App.log (orange box). Below the App-VNFC are two more App-VNFC boxes. Arrows show data flow from Log-Agents to the Log Collector, and from the Log Collector to the Platform. The Log Collector also sends data to a Log-Data-Repository (dashed red box) containing an Audit Bucket and a Log Bucket. The Log-Data-Repository sends data to a SIEM Server (light blue box) and a GUI (light blue box). A dashed line labeled 'Multi-Tenant Scenario' connects the Log-Data-Repository to another Cluster-Node box at the bottom.](286b26b15126a3ba268b5681f517d12b_img.jpg) + +Figure 4.1-1 Log-management architecture diagram. The diagram shows a Cluster-Node (light blue box) containing a Trusted-Environment (dashed red box). Inside the Trusted-Environment, there is a Logging-VNFC (purple box) containing three Log-Agents (blue boxes) and a Log Collector (blue box) with a Scheduler and Context-based Aggregation. Below the Logging-VNFC is a Platform (white box) with OS-level-audit.log (orange box). To the left of the Logging-VNFC is an App-VNFC (purple box) with App-audit.log (orange box) and App.log (orange box). Below the App-VNFC are two more App-VNFC boxes. Arrows show data flow from Log-Agents to the Log Collector, and from the Log Collector to the Platform. The Log Collector also sends data to a Log-Data-Repository (dashed red box) containing an Audit Bucket and a Log Bucket. The Log-Data-Repository sends data to a SIEM Server (light blue box) and a GUI (light blue box). A dashed line labeled 'Multi-Tenant Scenario' connects the Log-Data-Repository to another Cluster-Node box at the bottom. + +**Figure 4.1-1 Log-management architecture** + +The Cluster-Node is maintaining the VM-based and/or containerized product applications. These applications run as virtual network function components (VNFCs). (Refer to ETSI GR NFV 003 V1.5.1 (2020-01), [i.7]). + +The perimeter of a single tenant = trusted environment is represented by the Cluster-Node. The term trusted environment implies that any piece of SW that is up and running has been verified, either during boot process and/or during systems run-time. + +From log-management viewpoint, three different types of log-files are considered, these are the ‘normal’ application-level (normal-logs), the authentication-level (audit-logs), and the OS-level logs (system-logs). Each log-data is (logically) interfaced to a log-agent. The log-data is pushed to the log-agent, further, the log-agent is filtering for the relevant information and is providing this information to the log-collector. The log-collector is (logically) interfaced to every log-agent and is receiving the log-data. The log-collector scheduler is for push/pull of logs from/to the log-agents. The log-collector is providing the log-data to a log-data repository, which can then be accessed by a graphical user interface (GUI) for data visualization. The log-data will also be provided to the security information and event management (SIEM). The SIEM is a data aggregation tool. The aggregated data could be used for intrusion detection systems (IDS) and subsequent for intrusion prevention systems (IPS). + +### **Definition of Asset:** + +The term asset in this context refers to what is of worth to log-management and needs to be protected. + +The entire log-management function and the log-data represent the asset. Therefore the log-management function and the generated log-data must maintain confidentiality and integrity at rest and in use. For the definition of the security for the log-data in motion, the log-data server can be either standalone or can be part of the O-DU/SMO server. The lower layers (refer to TCP/IP [i.16] or OSI [i.15] networking model) are providing support for the confidentiality, integrity, and authentication protection of log-data in motion. + +![Figure 4.1-2 Definition of Asset: A diagram showing a 'Trusted-Environment' (dashed red box) containing an 'Asset' (purple box). Inside the Asset is a 'Log-Management' box (blue) with 'Log-data at rest or in use' below it. A double-headed arrow labeled 'Log-data in transit' connects the Log-Management box to a box below labeled 'TCP/IP or OSI networking models'.](ff987744738e233e788c537647268a9e_img.jpg) + +Figure 4.1-2 Definition of Asset: A diagram showing a 'Trusted-Environment' (dashed red box) containing an 'Asset' (purple box). Inside the Asset is a 'Log-Management' box (blue) with 'Log-data at rest or in use' below it. A double-headed arrow labeled 'Log-data in transit' connects the Log-Management box to a box below labeled 'TCP/IP or OSI networking models'. + +**Figure 4.1-2 Definition of Asset** + +The log-management as a function is creating log-data. For log-data that stays within the Trusted Environment, the log-data security applies to in use and at rest. For log-data that leaves the Trusted Environment, the log-data security applies to in motion. + +## 4.2 Definition of Event Sources + +The NIST cloud model is defining, among other things, cloud services, specifically Software as a Service (SaaS), Platform as a Service (PaaS), and Infrastructure as a Service (IaaS). For a more detailed description please refer to NIST SP800-145 [i.12]. + +The definition of cloud computing activities is as specified by ISO/IEC 17789:2014 [i.13]. + +Each of the cloud service is creating own log-data. + +**Table 4.2-1: Cloud Services vs. Event Sources (Overview)** + +| | Physical Devices | IaaS | PaaS | SaaS | +|------------------------------------------------------------------------|------------------|------|------|------| +| application-logs
(incl. normal-logs) | App | N/A | N/A | App | +| Audit-logs | App | App | App | App | +| System-logs
(incl. Cluster components-logs,
Journal-logs) | App | App | App | N/A | +| Developer-logs | App | App | App | App | + +Legend: App = Applicable, N/A = Not Applicable + +**Application-logs** (normal-logs), refer to log-data that has been created by the application SW which is running on top of the cloud infrastructure. + +**Audit-logs**, refers to Audit records that contain security event information such as successful and failed authentication attempts, file accesses, security policy changes, account changes (e.g., account creation and deletion, account privilege assignment), and use of privileges ([i.14]). + +**System-logs**, refer to cluster-node level logs. Typical log-sources are VNF components and/or journal-logs. + +**Developer-logs**, refer to log-data that has been created during product development. The log-data typically include development specific information which can be used for troubleshooting and debugging purposes. + +## 4.3 Security Log Data Lifecycle Management + +The security log-data lifecycle management includes the following: + +- The log-data generation refers to the creation and the collection of the log-data. The collection includes the filtering of log-data, i.e., which log-data to be stored and which not. This includes the classification of the log-data, specifically labelling of the log-data. +- The log-data at rest refers to the storage of log-data inside non-volatile memory (e.g., HDD, SSD, ...) ([i.17]). This includes the security controls for confidentiality and integrity protection of log-data, which is stored local and/or remote inside some repository/backup memory. This includes the tamper protection of log-data, and proper access controls to avoid unauthenticated access to sensitive log-data. +- The log-data in motion refers to the log-data transfer, i.e., moving data between compute nodes and over a data network. This includes the security controls for confidentiality, integrity, and peer-mutual authentication protection. This includes the consideration of regulatory requirements related to privacy, i.e., general data protection regulation (GDPR) valid regulatory for handling of privacy related data within European Union. +- The log-data in use refers to log-data stored in volatile memory (e.g., (S)RAM, memory caches, CPU registers). The main purpose of log-data in use is for the analysis and auditing. +- The log-data disposal refers to the retirement (end-of-life) of log-data. This includes the time when log-data is not needed any longer and therefore can be permanently deleted. This includes the sanitisation of the storage media. + +# --- 5 Key Issues + +## 5.1 Introduction + +This clause details the key issues identified for security aspects related to Security logs contents (payload), Security logs transfer mechanisms and Security logs formats/schemas. Each key issue defines the background to the issue, defines the threats related to the issue and proposes requirements that resolve or mitigate the key issue. + +## 5.2 Security logs contents + +### 5.2.1 Key Issue SLC#1: Logging all security related activity and events. + +#### 5.2.1.1 Key issue detail + +Logging is an integral part of any defense-in-depth strategy. The logging of specific events makes it possible to detect adversarial behavior. O-RAN comprises many different technologies that present an adversary with a large attack surface. Therefore, multiple events originating from the network and application layers should be logged. In addition, events generated dealing with data access, accounts and identity, and security mechanisms should also be logged. Aggregating these events is necessary to develop effective analytics that will detect adversarial behavior. + +#### 5.2.1.2 Security threats + +The following is a selection of threats applicable to O-RAN that have potentially loggable events. These threats have been selected from the references O-RAN Security Threats [i.1] and ATT&CK™ Containers Matrix [i.24]. + +- 5.2.1.2.1 Adversaries may abuse a container administration service to execute commands within a container [i.24, T1609]. +- 5.2.1.2.2 Adversaries may build a container image directly on a host to bypass defenses that monitor for the retrieval of malicious images from a public registry [i.24, T1612]. +- 5.2.1.2.3 Adversaries may deploy a container into an environment to facilitate execution or evade defenses [i.24, T1610]. +- 5.2.1.2.4 An adversary may rely upon specific actions by a user in order to gain execution [i.24, T1204]. +- 5.2.1.2.5 Adversaries may break out of a container to gain access to the underlying host [i.24, T1611]. +- 5.2.1.2.6 Adversaries may exploit software vulnerabilities in an attempt to elevate privileges [i.24, T1068]. +- 5.2.1.2.7 Adversaries may search compromised systems to find and obtain insecurely stored credentials [i.24, T1552]. +- 5.2.1.2.8 Adversaries may attempt to discover containers and other resources that are available within a container's environment [i.24, T1613]. +- 5.2.1.2.9 Adversaries may implant cloud or container images with malicious code to establish persistence after gaining access to an environment [i.24, T1525]. +- 5.2.1.2.10 Adversaries may abuse task scheduling functionality to facilitate initial or recurring execution of malicious code [i.24, T1053]. +- 5.2.1.2.11 Void +- 5.2.1.2.12 Altering a machine learning model (System manipulation and compromise of ML data confidentiality and privacy) [i.1, T-ML-02]. +- 5.2.1.2.13 An attacker exploits insufficient/improper mechanisms for authentication and authorization to compromise O-RAN components [i.1, T-O-RAN-06]. +- 5.2.1.2.14 Attacks from the internet exploit weak authentication and access control to penetrate O-RAN network boundary [i.1, T-O-RAN-03]. +- 5.2.1.2.15 An attacker bypasses authentication and authorization [i.1, T-rAPP-04]. +- 5.2.1.2.16 An attacker can exploit the improper/missing authentication weakness on SMO functions [i.1, T-SMO-01]. +- 5.2.1.2.17 Insecure channels with images repository [i.1, T-IMG-02]. +- 5.2.1.2.18 Weak orchestrator configurations, access controls and isolation [i.1, §5.4.2]. +- 5.2.1.2.19 Misuse of a VM/CN to attack other VM/CN, hypervisor/container engine, other hosts (memory, network, storage), etc. [i.1, §5.4.2]. + +5.2.1.2.20 Spoofing and eavesdropping on network traffic to access all O-RAN network data processed in the workload [i.1, §5.4.2]. + +5.2.1.2.21 Poisoning the ML training data (Data poisoning attacks) [i.1, T-ML-01]. + +5.2.1.2.22 Transfer learning attack [i.1, T-ML-03]. + +#### 5.2.1.3 Potential security requirements + +The following list of events are recommended to be logged. These events pertain to the network management and orchestration functions of O-RAN and not the radio parameters. The references 3GPP 33.117 [i.26] and VNF Security Events [25] list security events to log and have been reiterated here for the convenience of the reader. The references O-RAN Security Threats [i.1] and ATT&CK™ Containers Matrix [i.24] list threats so logging events have been extrapolated from those sources. + +##### 1) Log Network Events (including physical and virtual) such as: + +- a) Network connections, port down/up, packets over limit from firewall (see 5.2.1.2.20) [i.25, R-94525] [i.26, §4.2.3.6.1]. +- b) Changes to network configurations (see 5.2.1.2.20) [i.26, §4.2.3.6.1]. +- c) Changes to system configuration (see 5.2.1.2.20) [i.26, §4.2.3.6.1]. +- d) Resource usage, shortages, system crashes, reboots, and shutdowns [i.26, §4.2.3.6.1]. + +##### 2) Log Application Layer Events to include Virtual Network Function and Container Operations such as: + +- a) Lifecycle events, e.g., service creation/deletion/stop/start (see 5.2.1.2.18 and 5.2.1.2.19). +- b) Container and OS level administration services activities and executed commands. (e.g., Build requests, Runtime commands) (see 5.2.1.2.1 and 5.2.1.2.2). +- c) Image registry events (e.g., additions or modifications) (see 5.2.1.2.2 and 5.2.1.2.17). +- d) API calls (such as: system calls, those that deploy containers, discovery API, etc.) (see 5.2.1.2.3, 5.2.1.2.4, 5.2.1.2.5, 5.2.1.2.6, 5.2.1.2.7, 5.2.1.2.8, 5.2.1.2.9) +- e) Creation of scheduled jobs (see 5.2.1.2.10). +- f) Maintenance activity undertaken, recording whether maintenance was preventive or corrective [i.26, §4.2.3.6.1]. +- g) Change notifications [i.26, §4.2.3.6.1]. + +##### 3) Log Account and Identity Events such as: + +- a) All successful and unsuccessful authentication attempts, e.g., logins, to include maximum retries alert (see 5.2.1.2.13, 5.2.1.2.14, 5.2.1.2.15 or 5.2.1.2.16) [i.25, R-55478] [i.26, §4.2.3.6.1]. +- b) Successful and unsuccessful creation, modification, or deletion of user accounts or their privilege levels [i.25, R-07617] [i.26, §4.2.3.6.1]. +- c) All successful and unsuccessful authorization attempts to create a session, initiate a transaction, or assume an elevated privilege (see 5.2.1.2.13 and 5.2.1.2.15)[i.25, R-54520] [i.26, §4.2.3.6.1]. +- d) Termination of sessions, transactions, and downgrade in privileges. +- e) Change of group memberships [i.26, §4.2.3.6.1]. +- f) Creation, modification, or deletion of identities; and transactions executed by users in applications. +- g) Anonymous requests. + +##### **4) Log Data Access Events such as:** + +- a) Successful and rejected system or data access attempts such as database queries, read or writes to files and read or writes to learning models (see 5.2.1.2.12., 5.2.1.2.21, and 5.2.1.2.22). +- b) The addition, deletion, or modification of files (see 5.2.1.2.9). +- c) Types of files accessed. + +##### **5) Log Security Events such as:** + +- a) Starting and stopping of security logging [i.25, R-13344]. +- b) Activation and deactivation of security software (e.g., malware protection, DLP or IDS). +- c) Use of privileged rights or powerful utilities. +- d) Cryptographic operations + +### 5.2.2 Key Issue SLC#2: Log authentication attempts + +See clause 5.2.1 + +### 5.2.3 Key Issue SLC#3: Log encryption configuration information + +#### 5.2.3.1 Key issue detail + +Misconfiguration or malicious configuration in cryptographic protocols may indicate a threat actor or identify a potential threat vector within the system. + +O-RAN security specification requires O-RAN interfaces and -APIs to use security measures to protect vulnerable data and assets. Improper or missing security measures create vulnerabilities that can potentially be exploited by an attacker. + +E.g., O-RAN interfaces allow use of TLS or SSH. Industry best practices mandate the use of TLS (v1.2 or higher) or SSH PKI-based authentication. An implementation that implements TLS version lower than 1.2 or a SSH password authentication, may become the key source of vulnerability that a malicious code will exploit to compromise the O-RAN system ([i.1] , T-O-RAN-05). + +An attacker could, in such case, either inject malwares and/or manipulate existing software, harm the O-RAN components, create a performance issue by manipulation of parameters, or reconfigure the O-RAN components and disable the security features with the purpose of eavesdropping or wiretapping on various CUS & M planes, reaching northbound systems, attack broader network to cause denial-of-service, steal unprotected private keys, certificates, hash values, or other type of breaches ([i.1] T-O-RAN-06). + +O-RAN components may not be secured to industry best practices, i.e. improper or missing ciphering and integrity protection of sensitive data in storage or in transfer ([i.1] T-O-RAN-08). + +If the authentication of O-RAN external (e.g., AI/ML, Human-Machine) or internal (e.g., over O1 or O2 interfaces, with Non-RT RIC) interfaces on SMO is not supported or not properly implemented, those interfaces without valid certificates, or pre-shared keys could be able to establish a TLS connection with the SMO. The data stored in the SMO may be exposed to an attacker. + +#### 5.2.3.2 Security threats + +An adversary attack using vulnerabilities due to improper setup of security measures may not be detected. + +An adversary attack changing security configuration settings to open vulnerabilities may not be detected. + +#### 5.2.3.3 Potential security requirements + +Any change to a security-related configuration item should be logged as a security event. The logged event must include the metadata specified in SLF#1 and the event message must indicate the specifics of the configuration change [i.26, §4.2.3.6.1]. + +### 5.2.4 Key Issue SLC#4: Logging accesses to personal data + +#### 5.2.4.1 Key issue detail + +O-RAN components may not be secured to industry best practices, i.e., ciphering and integrity protection of sensitive data in storage or in transit may be improper or missing [i.1, T-O-RAN-08]. As a result, these O-RAN components might be vulnerable to attackers inappropriately accessing and/or disclosing of personal information. Further, this data may be subject to national or international law, such as the GDPR [i.31]. A security analyst may not notice the disclosure of personal data without traceability (logging) of access to personal data. + +#### 5.2.4.2 Security threats + +An adversary attack using vulnerabilities due to improper setup of security measures accessing personal data may not be detected. An attacker could, in such case, cause information disclosure, spoofing identity, elevation of privilege, etc. + +#### 5.2.4.3 Potential security requirements + +Any access to personal data should be logged, and the log should contain who accessed what data without revealing personal data in clear text as a security event. The logged event must include the metadata specified in SLF#1 and the event message must indicate the specifics of the access [i.26, §4.2.3.2.5]. + +### 5.2.5 Key Issue SLC#5: Logging events related to the Master Clock + +#### 5.2.5.1 Key issue detail + +The S-plane may be subject to attacks involving a Master clock of the timing network trying to impact the availability and accuracy of the delivered time and synchronisation information. To detect and analyse these attacks, events related to the master clock should be logged. + +#### 5.2.5.2 Security threats + +An attacker may + +- attack a master clock by sending an excessive number of time protocol packets or impersonate a legitimate clock, a slave, or an intermediate clock, by sending malicious messages to the master, thus degrading the victim's performance [i.1, T-SPLANE-01]. +- impersonate the master clock's grandmaster Identity value and proposing itself as a grandmaster candidate by sending fake ANNOUNCE messages declaring itself to be the best clock in the network ([i.1], T-SPLANE-02). +- propose itself as a grandmaster candidate by sending manipulated/malicious ANNOUNCE messages declaring itself to be the best clock in the network. The attacker causes other nodes in the network to believe it is a legitimate master [i.1, T-SPLANE-03]. +- position itself in such way that allows it to intercept and remove or delay valid synchronization packets. This leads to clock synchronization errors and inaccuracies of all clocks downstream or makes them go into free-running mode [i.1, T-SPLANE-04, T-SPLANE-05]. + +#### 5.2.5.3 Potential security requirements + +Any significant change to the configuration and performance of the PTP endpoints should be logged as a security event. The logged event must include the metadata specified in SLF#1 and the event message must indicate the specifics of the change. + +### 5.2.6 Key Issue SLC#6: Logging details of xApps + +See clause 5.2.1 + +### 5.2.7 Key Issue SLC#7: Logging details of rApps + +See clause 5.2.1 + +### 5.2.8 Key Issue SLC#8: Logging details of VNF/CNF + +See clause 5.2.1 + +### 5.2.9 Key Issue SLC#9: Logging information of dynamically loaded libraries + +#### 5.2.9.1 Key issue detail + +Any SW system potentially introduces security risks. These vulnerabilities are e.g., publicly available on the US-National Vulnerability Database (NVD). While this is intended for developers to disclose and resolve vulnerabilities, it is also used by hackers to exploit these. + +Vulnerabilities frequently propagate as developers re-use open- or closed- source code enabling backdoors to attacks. There have been notable vulnerabilities from downloading open-source libraries and dependencies, as well as supply chain risks when downloading Open-Source code from untrusted repositories. Developers may select SW components with known vulnerabilities and untrusted libraries that can be exploited by an attacker through a backdoor attack. Also, developers may intentionally insert backdoors in open- and closed- source code. + +#### 5.2.9.2 Security threats + +An attacker may + +- Exploit an existing vulnerability in a vulnerable version of dynamically loaded library [i.1, T-OPENSRC-01] +- Replace an invulnerable version of a dynamically loaded library with a vulnerable version, e.g. by downgrading to a previous, vulnerable version or by introducing a specifically crafted version +- Insert a vulnerability in the source code of a particular version of a dynamically loaded library [i.1, T-OPENSRC-02], which may not be detected. + +#### 5.2.9.3 Potential security requirements + +Load events of dynamically loaded libraries should be logged as a security event. The logged event must include the metadata specified in SLF#1 and the name and version information of the library being loaded. + +### 5.2.10 Key Issue SLC#10: Logging accesses to ML training data + +See clause 5.2.1 + +### 5.2.11 Key Issue SLC#11: No differentiation between M2M and human interfaces + +See clause 5.2.1 + +### 5.2.12 Key Issue SLC#12: Logging the identity of the person or process that originated the request, response, or the entity that originated the log message in the metadata + +See clause 5.2.1 + +### 5.2.13 Key Issue SLC#13: Maintaining unique system references in the logs + +#### 5.2.13.1 Key issue detail + +The lack of security events logged together with a unique system reference (e.g. host name, IP or MAC address) and the exact time the incident occurred do not allow a correct and rapid audit in case of security incident occurrence. Security restoration is delayed. Compromised availability and integrity of security event log files could conduct to delays, wrong audit results, delays in security restoration, threats persistence. + +#### 5.2.13.2 Security threats + +An attack may not be identified and located correctly and timely [i.1, T-O-RAN-07]. + +#### 5.2.13.3 Potential security requirements + +Security events are logged together with a unique system reference (e.g. host name, IP or MAC address) and the exact time the incident occurred [i.26, §4.2.3.6.1]. Proper unique system references are listed in clause 5.4.1.3 as 'Location Event Attribute' and 'Source Event Attribute'. + +### 5.2.14 Key Issue SLC#14: Synchronization of logs using common time sources + +#### 5.2.14.1 Key issue detail + +A common time source is crucial for security-related log timestamping because it ensures accurate and consistent timekeeping across various systems, devices, and applications within a network or organization. When security events occur and logs are generated, having synchronized timestamps allows for effective correlation, analysis, and response to incidents. Main uses are: + +##### **Accurate Event Sequencing** + +In security monitoring and incident investigation, the sequence of events is crucial. Accurate and synchronized timestamps enable analysts to reconstruct the chronological order of activities accurately, helping to identify the root cause and timeline of an incident. + +##### **Forensic Analysis** + +When investigating security breaches or incidents, forensic analysis requires the ability to track events across multiple systems. Accurate and synchronized timestamps facilitate the correlation of logs from different sources, aiding in the identification of patterns and anomalies. + +##### **Auditing and Compliance** + +Many industries and regulatory frameworks require organizations to maintain accurate logs for auditing and compliance purposes. Inconsistent or inaccurate timestamps could result in non-compliance issues and potential legal consequences. + +##### **Incident Response** + +During an incident, rapid response is essential. Accurate timestamps help security teams quickly identify the scope of an attack, assess the impact, and mitigate the threat effectively. + +##### **Distributed Environments** + +In modern IT landscapes, systems and applications are often distributed across various locations and time zones. Accurate and synchronized timestamps ensure that events are timestamped consistently, regardless of their physical location. + +#### 5.2.14.2 Security threats + +REF: ([i.1] T-O-RAN-07). + +**Data Integrity and Non-Repudiation:** Malicious actors may manipulate local system time to cover their tracks or cast doubt on the authenticity of evidence. This undermines data integrity and non-repudiation, making it difficult to prove the sequence of events accurately. + +**Attack Detection and Attribution:** If timestamps are inconsistent, identifying the source of an attack and its impact becomes challenging, potentially leading to delayed response and recovery. + +**Legal and Regulatory Compliance:** Organizations may be subject to legal actions or regulatory penalties if they cannot provide accurate and synchronized logs as required by regulations. + +**Delayed Incident Response:** Inaccurate timestamps may lead to confusion and delay in incident response efforts. Security teams may waste valuable time trying to reconcile conflicting timestamps rather than focusing on containing and mitigating the threat. + +#### 5.2.14.3 Potential security requirements + +The clock used to timestamp log events should be synchronized with a common time source. O-RAN elements should support NTP and/or GNSS. If NTP and GNSS are not available, then IEEE 1588 [i.47] might be an option. + +### 5.2.15 Key issue SLC#15: Emergency calls related logs + +void + +### 5.2.16 Key issue SLC#16: Logging details of O-Cloud + +#### 5.2.16.1 Key issue detail + +The continuous security of O-Cloud software (running VNFs/CNFs, Hypervisor/Container Engine, Host OS, control management, NFO/FOCOM) depends on the ability to identify attacks and reconstruct them. The earlier operators identify suspicious behavior and possible attacks, the faster they can initiate countermeasures. In the best case, they are able to stop severe attacks before harm is done. In the worst case, they at least are able to reduce the attacks severity and collect important details on the attack itself. This knowledge is important to find and fix flaws and vulnerabilities to prevent similar attacks in the future. Therefore, a key activity is to perform logging, monitoring and alerting. + +#### 5.2.16.2 Security threats + +REF: [i.1] §5.4.2, [i.18] CH-V10 - Security logs troubleshooting failure + +#### 5.2.16.3 Potential security requirements + +Any change to the O-Cloud components should be logged as a security event, and the logged event must include the identity of the entity making the change, the change, the date and the time of the change. + +Security logs should be time synchronized and regularly scanned for events of interest. + +Logs should be transferred to a log management platform outside O-Cloud to maintain their integrity and remove the risk of tampering. + +O-Cloud should secure and protect logs both in-transit in terms of integrity/authenticity and at rest in terms of integrity/availability. + +Such O-Cloud security events to be logged include: + +- The presence or loading of known vulnerable software that adversaries may drop and exploit to execute code in kernel mode. +- The deployment of suspicious or unknown App/VNF/CNF images in the O-Cloud platform. +- Interactions with images and VMs/Containers by users to identify ones that are added or modified anomalously. Changes is detectable by monitoring the VL (Virtualization layer) and the management platform audit logs. Logs provides insight into API calls including those that deploy VM/Containers. +- The change of VMs/Containers and O-Cloud configurations. +- Actions that could be taken to gather information about O-Cloud, including the use of discovery API calls by new or unexpected users. +- Resource creation, modification, or deletion for detecting misuse of the O-Cloud. +- Resource usage to determine anomalous activity associated with malicious hijacking of resources such as CPU, memory, network, and graphics processing resources. +- Attempts to escape from a privileged VM/Container to the underlying host and hardware. +- Any missing security patches. +- Activities related to the management and use of certificates and keys installed in O-Cloud (e.g., TLS certificates and keys). All operations should be logged such as view/list, renew, export, import, modify or delete commands. +- All cryptographic operations carried out within O-Cloud should be logged such as signature, encryption/decryption, hashing, key generation, key destruction. + +More details on events that should be logged in the VL and the management platform are provided in [i.19] for Red Hat OpenShift, [i.20] for Kubernetes, [i.21] for Docker, [i.22] for VMware and [i.23] for OpenStack. + +## 5.3 Security logs transfer mechanisms + +### 5.3.1 Introduction + +Logs are transferred across all the assets of the ORAN system with various possible capabilities at different layers. Whichever the mechanism, it is recommended that the logs are transferred securely across the system. + +### 5.3.2 Key Issue SLTM#1: Secure storage at rest + +#### 5.3.2.1 Key issue detail + +Improper or missing controls for protection of security event logs at rest, generated by O-RAN components, may not allow a correct and rapid audit in case of a security incident occurrence. Security restoration is delayed. Missing availability and integrity of security event logs could conduct to delays, wrong audit results, delays in security restoration and threat persistence ([i.1] §5.4.1.1). + +The security storage medium may have limited capacity, so lack of storage might cause security log event to be discarded. + +#### 5.3.2.2 Security threats + +REF: ([i.1] T-O-RAN-07). + +#### 5.3.2.3 Potential security requirements + +It is recommended that O-RAN security event logs stored in external systems and related to O-RAN are protected with access controls so only privileged users have access to those logs ([i.1] , §4.2). + +The security storage medium should be monitored for approaching capacity limits, and proper methods should be in place to avoid discarding log events, e.g. by + +- Issuing an alarm ([i.35], CON-LOG-REQ-15) +- Formalizing a log rotation mechanism ([i.35], CON-LOG-REQ-F9) +- Defining for the storage a minimum time period during which it needs to support the storage of all security log event ([i.35], CON-LOG-REQ-18) + +### 5.3.3 Key Issue SLTM#2: Study security logging best practices of ONAP Project + +See clause 5.3.2. + +### 5.3.4 Key Issue SLTM#3: Secure transfer protocols + +#### 5.3.4.1 Key issue detail + +Improper or missing controls for protection of security event logs in motion, generated by O-RAN components, may not allow a correct and rapid audit in case of a security incident occurrence. Security restoration is delayed. Missing availability and integrity of security event logs could conduct to delays, wrong audit results, delays in security restoration and threat persistence ([i.1] §5.4.1.1). + +In the O-RAN Open Fronthaul specification SFTP, FTPES have been already specified as secure file transfer protocols ([i.32], §5.1.4). HTTPS has been specified in 3GPP TS 28.537 ([i.33], §7.1.3). O-RAN O1 specification has been aligned ([i.34], §6.5.3). + +Log transfer protocols supporting log streaming would be a necessary addition to support near real time processing of the log events by a log analyzer. + +#### 5.3.4.2 Security threats + +REF: ([i.1] T-O-RAN-07). Potential security requirements + +#### 5.3.4.3 Potential security requirements + +It is recommended that security event logs being transferred are protected for confidentiality and integrity using reliable, secure protocols. It is recommended that secure file transfer protocols are used as defined in [i.32] and [i.34] when security event logs are transferred in the form of files. + +In addition, security event log transfer in the form of data streams should be supported, using reliable and secure stream transfer protocols such as syslog [i.36] over TLS [i.37]. + +### 5.3.5 Key Issue SLTM#4: Availability of logging + +#### 5.3.5.1 Key issue detail + +The process of logging in a complex network is subject to error conditions. In order to provide for logging availability, the logging system needs to be robust against these conditions. + +#### 5.3.5.2 Security threats + +The security threats associated with logging reliability include: + +- Outage of core elements of the logging system such as the SIEM +- Network connectivity outages +- Late arrival of logged events due to too large file size thresholds + +#### 5.3.5.3 Potential security requirements + +![Figure 5.3-1 possible configuration for log availability. The diagram shows a system architecture for log availability. On the left, a dashed box labeled 'Configurations' contains 'Streaming configuration to multiple SIEMs' and 'Temporary file retention period'. Below this, another dashed box labeled 'Factors for maximizing performance for Notification agent' contains 'File size', 'Number of NEs', 'Message size', and 'Fragmentation limit'. The main architecture shows a 'SIEM' box at the top, connected to an 'SMO' box. The 'SMO' box contains a 'Log buffer'. Arrows point from the 'SIEM' box to the 'Log buffer' and from the 'Log buffer' to the 'SIEM' box. Below the 'SMO' box is a 'Near RT RIC' box containing a 'Notification agent'. Below that is a 'CU-CP' box containing a 'Notification agent', and a 'CU-UP' box. Below that is a 'DU' box containing a 'Notification agent'. Below that is an 'RU' box containing a 'Notification agent'. At the bottom is an 'O-Cloud' box. Arrows show data flow from the 'Notification agents' in the 'Near RT RIC', 'CU-CP', 'CU-UP', 'DU', and 'RU' boxes to the 'Log buffer' in the 'SMO' box. An arrow labeled 'Open fronthaul m-plane' points from the 'RU' box to the 'Log buffer'. An arrow labeled 'O1' points from the 'Log buffer' to the 'Near RT RIC'. An arrow labeled 'O2' points from the 'Log buffer' to the 'SIEM' box.](b7309ad0714cf8617b76a86886fd6f52_img.jpg) + +Figure 5.3-1 possible configuration for log availability. The diagram shows a system architecture for log availability. On the left, a dashed box labeled 'Configurations' contains 'Streaming configuration to multiple SIEMs' and 'Temporary file retention period'. Below this, another dashed box labeled 'Factors for maximizing performance for Notification agent' contains 'File size', 'Number of NEs', 'Message size', and 'Fragmentation limit'. The main architecture shows a 'SIEM' box at the top, connected to an 'SMO' box. The 'SMO' box contains a 'Log buffer'. Arrows point from the 'SIEM' box to the 'Log buffer' and from the 'Log buffer' to the 'SIEM' box. Below the 'SMO' box is a 'Near RT RIC' box containing a 'Notification agent'. Below that is a 'CU-CP' box containing a 'Notification agent', and a 'CU-UP' box. Below that is a 'DU' box containing a 'Notification agent'. Below that is an 'RU' box containing a 'Notification agent'. At the bottom is an 'O-Cloud' box. Arrows show data flow from the 'Notification agents' in the 'Near RT RIC', 'CU-CP', 'CU-UP', 'DU', and 'RU' boxes to the 'Log buffer' in the 'SMO' box. An arrow labeled 'Open fronthaul m-plane' points from the 'RU' box to the 'Log buffer'. An arrow labeled 'O1' points from the 'Log buffer' to the 'Near RT RIC'. An arrow labeled 'O2' points from the 'Log buffer' to the 'SIEM' box. + +**Figure 5.3-1 possible configuration for log availability** + +SMO – The SMO plays the role of enabling availability of the logs. In case the SIEMs server support the configuration of redundancy then the SMO server will be capable of sending the logs to any of the instances depending on the active SIEM server at that point in time. + +In addition, the SMO server also maintains an optional buffer to store logs in case the connectivity to the SIEM server goes down. + +The other entities below the SMO which are forwarding the logs also strive to ensure the entire system is available by supporting parameters which keep the performance of the system optimal. The optional parameters that could be supported by the various entities are + +- File size – the limit of the file size after which a notification could possibly be sent to the SMO that the file can be retrieved +- Number of NEs – the maximum number of Network Elements that can dump security logs in one file +- Message size – the length of the message size in case streaming is supported + +- Fragmentation Limit – the size of the granular fragments that can be supported when data can be collected for a minimal size and then forwarded + +## 5.4 Security logs formats + +### 5.4.1 Key Issue SLF#1: Standardized logging metadata to support security analytics + +#### 5.4.1.1 Key issue detail + +The intent of this key issue is not to define a logging format. There are many existing logging formats [i.28], and despite the selection of a logging format, many of the analytics tools presently are very flexible and support multiple formats. Instead, this key issue specifies that logged security event messages require additional detail referred to as event attributes to enable effective security analytics. Event attributes should indicate the time, location, source, and event type [i.27] (see Figure 5.4-1). An analytics engine can use these event attributes downstream to identify adversarial operations within the O-RAN environment. + +Event attributes typically include a field to indicate the event type. However, the event type field has been omitted since the scope of this technical report is limited to only security events. Thus, the field would have just been a static value. + +![Figure 5.4-1 Security Event Entry diagram showing a Logged Security Event structure with Event Attributes (Time, Location, Source) and Security Event Message.](029fa62d9300e01961ef344254850b13_img.jpg) + +``` + +graph TD + LSE[Logged Security Event] + EA[Event Attributes] + SEM[Security Event Message] + T[Time] + L[Location] + S[Source] + + LSE --- EA + LSE --- SEM + EA --- T + EA --- L + EA --- S + +``` + +Figure 5.4-1 Security Event Entry diagram showing a Logged Security Event structure with Event Attributes (Time, Location, Source) and Security Event Message. + +Figure 5.4-1 Security Event Entry + +#### 5.4.1.2 Security threats + +As adversaries operate within an environment, they will generate many log events. Therefore, a correlation of these log events will be necessary to detect adversary behavior. For successful correlation, it will be essential for log events to have event attributes as specified in Figure 5.4-1. + +#### 5.4.1.3 Potential security requirements + +The following event attributes should be included with every logged security event. + +##### 1) Time Event Attribute: + +The date and time should be included with every log entry. This will allow for correlations and time series analysis of security events. + +- The format of the date and time should be standardized. ISO 8601 is an example of such an appropriate standard. +- Precision for the time component should be at least to the second. Precision to the millisecond may be considered for near-real-time and real-time events. + +##### 2) Location Event Attribute: + +The location refers to what VM, VNF, PNF, code module, or communication exchange the security event was generated. With location information, log correlation will allow for tracing adversary movement across the O-RAN architecture or alerting a SOC to monitor a specific O-RAN component more closely. Depending on the context for which a security event is logged, one of the below items may be a suitable reference for the location event attribute. + +- O-RAN function name (e.g., O-DU, O-RU, O-CU, Near RT RIC, etc.). +- The O-RAN interface name (e.g., A1, O1, O2, etc.) if it is an inter-function communication. + +- c. The source IP address and destination IP address if it is an inter-function communication. + - d. Applications Identifiers (app IDs) for xApps and rApps. + - e. VM or Container names. + - f. PNF names. + - g. Code module or function name. +- 3) **Source Event Attribute:** +The source refers to the person, process, or service that is the cause of the security event. Depending on the context for which a security event is logged, one of the below items may be a suitable reference for the source event attribute. +- a. Source IP address. + - b. User identity if known. + - c. UE associated identifiers as specified in ([i.29], §4.5) + +### 5.4.2 Key Issue SLF#2: Logging the field “date/time” in the metadata of the security audit logs. + +See clause 5.4.1 + +### 5.4.3 Key Issue SLF#3: Standardized logging format + +See clause 5.4.1 + +## 5.5 Log management security framework + +### 5.5.1 Key Issue LMSF#1: Trusted environment for cluster node + +#### 5.5.1.1 Key issue detail + +The VNFC is up and running (instantiated) and is creating entries into the log-files. Security professionals will use log-entries for forensic analysis in case of a security event, therefore any piece of SW (VNFC) that is going to be executed must be verified. The verification is ensuring that at time of verification the VNFC has not been altered. The verification could be at boot-time and/or during run-time. On lower layers the physical devices, as such, create log-entries, which also need to be taken into consideration. + +#### 5.5.1.2 Security threats + +The attacker is running unauthenticated VNFC. + +#### 5.5.1.3 Potential security requirements + +Secure boot and/or Trusted boot. + +### 5.5.2 Key Issue LMSF#2: Trusted environment for log-data repository + +#### 5.5.2.1 Key issue detail + +The log-data repository has stored audit-logs and normal-logs. Some of the logs might include sensitive information, and some other log-data might be from different owners/tenants. Access controls need to be implemented, and the permission for changes is assigned to privileged users. + +#### 5.5.2.2 Security threats + +Users gain unauthenticated access to log-data stored in repository. + +Unauthorized users granted read/write access to log-data stored in repository. + +Users remove log-entries and/or log-data stored in repository. + +#### 5.5.2.3 Potential security requirements + +Enforcement of user access controls (identity management) + +Enforcement of confidentiality and integrity protection of log-data + +### 5.5.3 Key Issue LMSF#3: Log-data lifecycle management + +#### 5.5.3.1 Key issue detail + +The log-data lifecycle management is defined inconsistently across the different lifecycle phases. + +#### 5.5.3.2 Security threats + +NOTE: Adding the whole Log-Data Lifecycle as a key-issue, is just to get reviewed every phase, and from that to identify potential (new) security threats. + +#### 5.5.3.3 Potential security requirements + +Definition of a Retention Policy per Tenant. + +### 5.5.4 Key Issue LMSF#4: (D)DoS to log-data management + +#### 5.5.4.1 Key issue detail + +Security events will be documented in (tracked by) log-data. Every security event is creating at least one log-entry. Every log-entry is filling-up the log-data. Finite memory space for storing the log-data, consequently means size of log-data is finite as well. + +#### 5.5.4.2 Security threats + +The attacker is driving (most probably wrong) actions, with the aim to trigger security events, the security events will be logged, the log-files will be overfilled. The overfilling/-loading of logging is primary aimed for hiding actions, this attack vector might also be used to drive (D)DoS for the whole systems, i.e., DoS due to VNFC processing performance leakage. + +#### 5.5.4.3 Potential security requirements + +Log-data injection detection. Log-data shaping. Log-data backing-up procedures. Proper configuration of log-data management system. + +### 5.5.5 Key Issue LMSF#5: Tampering of log-data + +#### 5.5.5.1 Key issue detail + +Attackers/hackers attempt to access and tamper log-data with the aim to hide their actions. Access to log-data in use, at rest and in motion. + +#### 5.5.5.2 Security threats + +#### 5.5.5.3 Potential security requirements + +Remote logging (log real time streaming). Replication of Log-data. + +### 5.5.6 Key Issue LMSF#6: Authenticated timestamping and log-data + +#### 5.5.6.1 Key issue detail + +The timestamping is the essential part of log-file-reviews, i.e., after a security event the security professionals try to reproduce who was doing what and when. The time stamping is helping to reconstruct all logged security events versus and logged actions over time. The reconstruction can be over different log-files and some cases additionally over different VNFC, maybe also over different locations. Therefore, the time must be standardized across all involved system components. + +#### 5.5.6.2 Security threats + +The attacker causes the clock to become out of synchronization with the other clocks in the O-RAN deployment in order to hide the sequence of security events. + +#### 5.5.6.3 Potential security requirements + +Network Time Security for NTP (RFC8915), NTPv4 support (RFC5905) + +### 5.5.7 Key Issue LMSF#7: Due diligence - log-data auditing + +#### 5.5.7.1 Key issue detail + +The log-data creation and provision to log-data repository is primary used as input to detective controls, like detecting an unauthorized use of, or attack upon a VNFC. The activation of log-management and the forensic analysis of the log-data is helpful only if security professionals perform log-data auditing regular or at least at security event notifications. + +#### 5.5.7.2 Security threats + +Every undetected attack attempt increases the risk of a successful attack on the O-RAN deployment. + +#### 5.5.7.3 Potential security requirements + +Definition of checklist for log-data auditing. Definition of log-data auditing process. + +# 6 Mitigations and Solutions + +## 6.1 Introduction + +This clause contains any potential Mitigations or Solutions that may be used to address or reduce the risk associated with Key Issues identified in clause 5. + +The idea behind collecting security logs is to monitor who is doing what, when and why in a network. This is typically carried out with the help of a SIEM, which is out of scope for the O-RAN Alliance and is not specified by the O-RAN Alliance. + +SIEM is a common approach used to aggregate log data from multiple sources. SIEM systems can parse and analyze data in real time to identify deviations from established baselines. If an anomaly is detected, SIEM systems can generate alerts, possibly activating additional security mechanisms. They can be rules-based, often employing a statistical correlation engine to establish relationships between event log entries. Advanced systems also rely on user and entity behavior analytics, as well as security orchestration, automation and response tools. To detect and be alerted on deviations from the baselines it is recommended to implement quality logs with the following guidelines: + +- The sources capturing the logs should focus on the appropriate content captured at the appropriate time +- All layers in ORAN record log events appropriately in accordance with the larger usecase in context + +## 6.2 Solution#1: Trusted environment for cluster node + +### 6.2.1 Introduction + +The log-data life starts with the log-data generation and their storage in either local (e.g., non-volatile memory) or remote storage, i.e., log-data will be streamed to a remote log collection entity and/or log-data repository. Different cloud services create different log-data with different type of content. + +For the log-data the lifecycle management applies as described by clause 4.3. + +However, for all above phases of a lifecycle the trusted environment plays a major role, as this defines the boundary from trustworthy to untrustworthy environment. In a trusted area, security controls may be neglected, which does not mean that efforts are negligible, but rather that efforts are focused on achieving the trusted environment. In more simple words, the trusted environment is creating a trust boundary and allows reduction of security controls within. + +### 6.2.2 Solution details + +#### Log-Data Storage: + +- The log-data should be protected with the help of the trusted environment. +- The log-data should be created within a trusted environment. +- The log-data should be stored in non-volatile memory of the local trusted environment. This applies to back-up log-data as well. +- Any log-data modification should be logged. + +#### Log-Data Access Management: + +- The access to log-data should only be possible within the local trusted environment. +- The authorized access to log-data should be supported. The term ‘access’ in this context refers to write permission and read permission. +- The change of access rights of log-data should only be possible for privileged users. + +#### Log-Data Handling during Boot Process, at Run-Time and System Failure: + +NOTE: This clause is as well considering the handling of log-data for the different services. + +- All the log-data relevant for platform services should be created. +- All the log-data relevant for infrastructure service should be created. +- All the log-data per tenant (i.e., App VNFC) should be created and maintained in dedicated files. The log-data per tenant should be kept independent of the lifetime of the App VNFC. +- The log-data should provide information to deduce the root cause of a system failure. +- Any type of log-data in use should be stored in non-volatile memory before system shutdown. + +#### Log-Data Files in Motion: + +The log-data files that are going to leave the own trusted environment should be confidentiality, integrity and replay protected. A mutual authentication should be performed for the setup of the secure communication channel. + +#### Log-Data (Files) Policy: + +- For the log-data file lifetime a retention policy should be defined. +- For details, please refer to clause 6.4 on log-data lifecycle management. + +### 6.2.3 Evaluation + +The log-files and the log-data respectively will be created and maintained with the trusted environment. + +Authorized read and write permission to log-data and only throughout the own trusted environment. In other words, it will not happen that any subject and/or object get access to log-data from outside of the trusted environment. + +The log-data from different tenants remain valid independent to whether the tenant has deactivated its App VNFC. + +Rationale: This ensures a post-analysis of an App VNFC activity. + +## 6.3 Solution #2: Trusted environment for data repository + +### 6.3.1 Introduction + +The log-data life starts with the log-data generation and their storage in either local (e.g., non-volatile memory) or remote storage, i.e., log-data will be streamed to a remote log collection entity and/or log-data repository. Different cloud services create different log-data with different type of content. + +For the log-data the lifecycle management applies as described by clause 4.3. + +However, for all above phases of a lifecycle the trusted environment plays a major role, as this defines the boundary from trustworthy to untrustworthy environment. In a trusted environment, some security controls protecting security logs may be optional as the trusted environment provides the necessary protection for all its contents.' In more simple words, the trusted environment is creating a trust boundary and allows reduction of security controls within. + +### 6.3.2 Solution details + +#### Log-Data Storage: + +- The log-data should be protected with the help of the trusted environment. +- The log-data that is stored inside the trusted environment can be from one source (cluster node) or from different sources (cluster nodes). The trusted environment of a cluster node and that of the repository should be mutually authenticated. For details, please refer to the clause 6.11 Solution #10: Secure transfer of logs. +- The log-data should be stored in non-volatile memory of the local trusted environment. This also applies to back-up log-data. + +- Log-data integrity needs to be always protected. + +#### Log-Data Access Management → Authentication: + +It should be verified whether the subject has been authorized to use the presented identifier by a trusted identity provider organization. + +#### Log-Data Access Management → Authorization: + +For the log-data management the support of attribute-based access control according to NIST SP800-162 should be supported. + +NIST definition of Attribute Based Access Control (ABAC) [i.38]: + +*“An access control method where subject requests to perform operations on objects are granted or denied based on assigned attributes of the subject, assigned attributes of the object, environment conditions, and a set of policies that are specified in terms of those attributes and conditions.”* + +Subject in this context is meant to be a human user or non-person entity (NPE), while the Object in this context refers to be a system and/or resource for which access is managed by the ABAC. An operation in this context refers to the execution of a function at the request of a subject upon an object. This includes the read, write, edit, delete, copy, execute and modify. The policy in this context refers to the rules and relationships that makes it possible to determine if requested access should be allowed, given the values of the attributes of the subject, object, and possibly environmental conditions. + +The core ABAC mechanisms include: + +- Subject Attributes +- Resource Objects Attributes +- Access Control Rules (Policy) +- Environmental Conditions + +The perimeter for the access control is given/defined by the trusted environment. + +The change of access rights of log-data should only be possible for privileged users and always from inside the log-data repositories trusted environment. + +#### Log-Data Files in Motion: + +The log-data that are going to leave the own trusted environment should be confidentiality- and integrity protected. A mutual authentication should be performed for the setup of the secure communication channel between trusted environments. + +For the log-data repository there should be support for log-data streaming (one-way) from the cluster node. The log-data repository should separate/isolate the log-data from different trusted environments by properly assigning the attributes. + +For the log-data repository there should be support for authenticated and authorized access from a graphical user interface (GUI) for instance. + +#### Log-Data Policy: + +For the log-data file lifetime a retention policy should be defined. For details, please refer to clause 6.x on “log-data lifecycle management”. + +### 6.3.3 Evaluation + +The log-files and the log-data respectively will be collected and maintained within the trusted environment of the log-data repository. + +The log-data of different trusted environments need to be kept isolated from each other. + +The access controls for different trusted environments need to be kept isolated from each other. + +## 6.4 Solution #3: Solution on log-data life cycle management + +### 6.4.1 Introduction + +This log-data life cycle management clause has been defined as an own clause, this just to ensure all phases of life of a log-data has been considered properly. + +The log-data lifecycle management can be based on the NIST Guide to Computer Security Log Management [i.14]. + +### 6.4.2 Solution details + +#### Log-Data Creation and Storage (at rest): + +The log-data, specifically log-data of security events, will be created and thereafter need to be stored inside a non-volatile memory. The log-data should be stored inside a log-data repository, immediate after its creation. (please refer to clause 6.13 on “preventing tampering of log-data”). + +Support of log-data rotation which is configurable at regular time (e.g., hourly, daily, weekly) and when the maximum log size is reached. + +The creation and storage of security log-data must always be possible. In other words, stop the logging of security events is an unacceptable option. + +#### Log-Data in Motion: + +The log-data should be privacy and integrity protected. + +#### Log-Data in Use: + +The log-data should be protected with the help of the trusted environment. + +#### Log-data Retention: + +The retention policy is specific to business rules and strictly depends on applicable laws, like GDPR. Therefore the applicable laws should be considered. + +For the long-term storage of log-data the following applies: + +- The storage format of log-data should be in a standardized format. This ensures that log-data remain readable and interpretable after years. +- If the log-data source is proprietary, then the storage format of log-data should be in proprietary format as well. The assumption here is, that proprietary logging tools collect a lot more log-data, which might disappear in case of their transfer into a standardized format. However, this retaining the log-data in proprietary format ensures that all logged information is available. + +- The archived log-data and their media should be checked periodically to determine whether there is a risk for becoming inaccessible. +- The archived log-data need to receive adequate physical protection. +- The archived log-data should not include personally identifiable information (PII). + +### 6.4.3 Evaluation + +The log-data lifecycle requirements are now specified for the different phases of the life of a log-data. Some of the log-data requirements depend on applicable laws and company business, therefore applicable laws and company policies need to be taken into consideration. + +## 6.5 Solution #4: Solution on (D)DoS to log-data management + +### 6.5.1 Introduction + +In practice the denial-of-service attack is a performance consuming attack that has the primary goal of preventing the legitimate activity on a victimized system. There exist two basic forms of denial-of-service, the first attack is exploiting a vulnerability, and the second is that the attack is overflowing the victim's system. In practice either the communication channel is going to be overflowed which leads to that legitimate traffic cannot reach the victim's system, or which leads to the victim's processing power is used up completely. + +From the log-data collection perspective the denial-of-service is leading to blocking of collecting and storing of security events. + +### 6.5.2 Solution details + +The log-data management system should support a rate limiting and a shaping. Both functions should be configurable with the help of the trusted environment. + +The log-data management system should create a log-data entry for any type of denial-of-service. In the unlikely event of a denial-of-service the victims' system should still maintain sufficient processing power for security logging. + +### 6.5.3 Evaluation + +The response of a denial-of-service attempt can be rate-limiting and/or shaping. This does not prevent from a denial-of-service, rather this is saving some performance capacity for logging while the ongoing denial-of-service. + +## 6.6 Solution #5: Solution on authenticated time stamping + +### 6.6.1 Introduction + +For any type of log-data review the time (UTC) needs to be synchronized, especially if the reconstruction of security events can be over different tenants. + +### 6.6.2 Solution details + +The Network Time Protocol (NTP) version 4 should be supported as specified by RFC5909 in case no other reliable time source is available. + +If NTPv4 authentication is supported, then AES-CMAC (RFC4493) should be supported. In this case the NTP client can verify the integrity of the received NTP-packet. + +If NTP security is supported, i.e., integrity and replay protection of NTP-packets, then NTS (RFC8915) should be supported. In this case the NTP client can verify the authenticity of the NTP packets by use of X.509 PKI infrastructure. For this purpose, the NTP client needs to be authenticated with the help of the trusted environment. + +### 6.6.3 Evaluation + +The support of NTPv4 (RFC5905) together with AES-CMAC is providing evidence in case the NTP-packets have been altered/modified. This solution does not mitigate the replay attack. + +The integrity and replay protection can be supported by implementing the NTS. + +## 6.7 Solution #6: Solution on due diligence and log-data auditing + +### 6.7.1 Introduction + +This solution suggests the formalization of security log management policies and procedures. In addition, it suggests the development of formalized security logging structure which is based on standards, baselines, and guidelines. All these aspects refer to Due Care. On organization level, the Due Care is protecting the interest of an organization, while the Due Diligence is practicing the policies and procedures. + +The term Due Diligence in the context is referring to practicing of all formalized security log management. + +The Due Diligence on log-data is based in the NIST Computer Security Log Management ([i.14]). + +### 6.7.2 Solution details + +This clause is not intended to serve as requirements, as such matters may fall outside the scope of the present document. For further guidance it is suggested to reference NIST SP 800-34 [i.55] and NIST SP 800-61 [i.56]. + +#### Log Analysis Scope and Criteria + +- Log-data scope definition + - Define the types of log-data to be analyzed, including specific criteria for application software, infrastructure and platform levels. +- Analysis frequency guidelines + - Establish guidelines for how often log-data should be analyzed for each level: Critical, High, Low, Informational and Debug +- Critical information identification + - Identify critical log-data components that require regular in-depth analysis, which may include + - Security events + - Performance metrics + - Error and exception log-data + - User activity + - Infrastructure changes +- Automated analysis considerations + - Consider the implementation of automated log-data analysis tools to efficiently analyze large volumes of log-data. + +- Ensure the automated log-data analysis tools and processes effectively identify patterns and recognize critical information. + - Automated log-data analysis tools scope is limited to the escalation to personnel able to triage, interpret and initiate response effectively, unless pre-determined automated actions have been defined and tested. +- Documentation of analysis criteria + - Ensure criteria for log-data analysis is clearly documented. + - Log-data documentation is available for reference by analysts and other relevant stakeholders. + +#### Access to log-data and the logging of log-data access: + +- Access Authorization Definition + - A comprehensive and clear definition is established to identify individuals and specify roles for access to log-data. +- Access Control Mechanism + - Each component receiving O-RAN security log-data implements a robust access control mechanism to ensure only authorized individuals are able to access log-data. +- Logging Requirement + - The availability of log-data for all authorized individuals is ensured by redundant measures. + - Each attempt to access log-data is logged, recording details such as identity, purpose of log-data access and timestamp. +- Audit Trail + - The system maintains a detailed audit trail for all access or access attempts to log-data. + - The audit trail is only accessible to individuals responsible for overseeing logging and system security. +- Review and Update + - The access authorization and logging mechanisms are periodically reviewed and updated as necessary for changing security and personnel requirements. + +#### Log Management Infrastructure Governance: + +- Definition of Authority and Responsibility + - Clearly define roles and personnel authorized to establish and manage the log management infrastructure within the organization. +- Authorized Activities + - Implement security controls to allow designated individuals to perform activities, including infrastructure setup, configuration management, access control and log-data rotation. +- Documentation of Responsibilities + - Document and clearly communicate responsibilities to personnel authorized to establish, maintain and manage log infrastructure. +- Security and Compliance + - Ensure prioritization of security best practices, conduct regular audits, and ensure compliance with regulatory standard requirements. +- Training and Coordination + +- Provide training and skill development programs that align with the organization's IT and security policies. +- Establish effective coordination across log-data management and security teams. + +#### Intrusion Response: + +- Definition of intrusion response + - A comprehensive and clear definition of the intrusion response is established to include the necessary response activities to be performed in the event of a breach or intrusion. +- Response Activities + - Identification – Promptly detect and identify signs of unauthorized access. + - Containment – Isolate affected systems to prevent further spread and potential damage. + - Eradication – Identify and eliminate the root cause, ensuring complete removal of any unauthorized access or changes. + - Recovery – Restore affected components, verifying the integrity of restored components. + - Improve security posture – Conduct a thorough analysis of the intrusion and proceeding response to help improve security posture, detection capabilities and response methods. +- Response Team and Roles + - There is a clearly defined intrusion response team with corresponding duties for the response plan to ensure effective execution. +- Communication Protocols + - Effective and reliable communications are established and tested to ensure the accurate and efficient spread of information within the response team and to relevant stakeholders. +- Documentation and Reporting + - Comprehensive documentation and reporting mechanisms are established to record each step of the intrusion response, including actions taken and timeline. +- Legal and Compliance Adherence + - The intrusion, the intrusion response plan and corresponding activities are reported to legal and compliance as per organization policy and jurisdiction. + +#### Log Analysis Security Measures + +- Confidentiality, Integrity and Availability + - Clearly define measures for ensuring the confidentiality, integrity and availability of log-data analysis capabilities, ensuring the protection of data at rest and in motion. +- Confidentiality safeguards + - Implement encryption protocols as per O-RAN Security Protocols Specification [i.3] to ensure confidentiality, mitigating unauthorized access. +- Integrity verification + - Implement mechanisms to verify and maintain integrity, employing techniques such as digital signatures outlined in O-RAN Security Requirements and Controls Specifications [i.2]. +- Redundancy for availability + +- Establish redundancy measures such as high availability nodes to ensure availability and minimize downtime. +- Define and implement backup measures to ensure recovery availability in the event of catastrophe. +- Secure storage + - Define secure storage practices for data at rest, including access controls and regular audits. + +#### Inadvertent Disclosure Handling + +- Inadvertent disclosure definition + - Clearly define what constitutes an inadvertent disclosure of sensitive log-data, establishing a clear understanding within the organization. +- Incident Identification + - Develop procedures to promptly identify disclosures, utilizing monitoring tools and anomaly detection. +- Notification + - Establish clear notification protocols to inform relevant stakeholders when a disclosure has been identified. Ensure transparency and timely response. +- Containment + - Implement containment strategies to limit the impact of disclosures, such as isolating affected systems or restricting access to log-data. +- Root Cause Analysis + - Conduct a thorough root cause analysis to gain understanding of contributing factors. + - Review of system logs – Identify points of failure or vulnerabilities. + - Review access controls – Assess the effectiveness of controls and permissions to help identify misconfigurations. + - Analyze user action – Identify whether the disclosure resulted from misconfiguration, malicious activity, or human error. + - Document findings – Comprehensively document details of the sequence of events and identified vulnerabilities. + - Utilize root cause analysis results to facilitate preventive measure improvements. +- Continuous Improvement + - Integrate learned lessons from disclosures into an improvement cycle, adjusting policies to improve the organization's security posture. +- Legal and Regulatory Compliance + - Ensure that all response aligns with legal, regulatory and jurisdiction requirements. + +### 6.7.3 Evaluation + +This Due Diligence aspect is more related to practicing all the defined policies and procedures throughout the log-management infrastructure. The policies and procedures are dependent on applicable regulatory and laws, and especially on the organizations interest. + +## 6.8 Solution #7: Log format + +### 6.8.1 Introduction + +Logs are captured in various formats across the network sources and collected at the central trusted location where the logs need to be unified. Hence we have the need of normalizing the logs. + +The common approach is that log formats are chosen for various components preferably based on known standards with a higher-level central function which focuses on the normalization. + +![Diagram illustrating Log Normalization. A central box labeled 'Log Normalization' receives input from three boxes below it: 'Syslog format', 'CEF', and '...'. A bracket on the left groups these three boxes under the label 'Various log formats'.](2b77b79aca6255c5539f79ed016c91d4_img.jpg) + +``` + +graph BT + A[Various log formats] --> B[Syslog format] + A --> C[CEF] + A --> D[...] + B --> E[Log Normalization] + C --> E + D --> E + +``` + +Diagram illustrating Log Normalization. A central box labeled 'Log Normalization' receives input from three boxes below it: 'Syslog format', 'CEF', and '...'. A bracket on the left groups these three boxes under the label 'Various log formats'. + +**Figure 6.8-1 Log Normalization** + +### 6.8.2 Solution details + +#### 6.8.2.1 Normalisation of logs + +o Converting each log data field to a particular data representation and categorizing it consistently for higher level SIEM systems to parse one format of data efficiently. One possible option is defined in [i.39]. + +#### 6.8.2.2 Syslog – possible standard format + +- Syslog is a standard format providing key value pairs. This is defined in [i.36]. Meaningful keys can be created such that they are able to be used by the SIEM system for analytics +- Values are free text string, numeric, enumerators, etc. + +**Log Message Structure** + +Timestamp;Key=; Key=;Key=;Key=;... + +Example log message + +``` + +2015-10-06T13:00:07.000+0530I(901,994)ISECURITY_SUCCESSIcom.smo.logISMObtivatedauditI +Source='Server'IUser identity='jack'IOperation identifier='enableSMO'I Success code='T'I Cause code='N/A'I +Identifier='SUCCESS'I Target element='PLMN-PLMN/O-DU-1'I Client address='10.10.10.1'I Source session +identifier=''I Target session identifier=''I Category code=''I Effect code='M'I Network Transaction +identifier='smo.123'I Source user identity=''I Target user identity=''I Timestamp='1444118542117' + +``` + +**Figure 6.8-2 Log message structure and example log message** + +### 6.8.3 Evaluation + +The proposed solutions aim at resolving key issues SLF#1-3. + +## 6.9 Solution #8: Log content: key fields for all security log events + +### 6.9.1 Introduction + +Several events that should always be captured and logged to ensure user accountability and to help operators detect, understand and recover from an attack as explained in [i.50]. Such events include all the key issues addressed in clause 3. + +Basically the goal would be to categorize the content under the below themes as explained in the table. + +**Table 6.9-1 Log Content** + +| Log content | | +|-------------|---------------------------------------------------------------| +| Who | User/machine who carried out the usecase | +| What | What was done on the network in the context of the uecase | +| When | The time and date as to when this usecase was carried out | +| Why | The context of the uecases or operation in the larger picture | + +### 6.9.2 Solutions + +The who did what, when and why are translated to the below table which provides some important key fields and its description but not limited to: + +**Table 6.9-2 Key fields** + +| Key | Value (Description) | +|--------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------| +| Time | Time and date of the operation | +| User/Identity | Identifies account name of the user responsible for the operation. | +| Operation identifier | Identifies the operation | +| Result | Success or Failure | +| Target | Identifies target network element or DN (Distinguished Name) of the operation. | +| Category | Identifies what type of data operation was performed with predefined operation category codes | +| Effect | Identifies how the operation affected or attempted to affect target data, i.e. whether it created new data, read data etc. Like the CRUD operations | +| Client address | Address of the host the user was connected from | +| Resource | Application specific resource on which this operation was performed. | +| Target session identifier | Session identifier | +| Target User Identity | User identity used for logging in to external system in case this is different | +| Network Transaction identifier | Identifies transaction of which this operation is part. If used, the field values shall be unique across the whole network, not only single server. | + +### 6.9.3 Evaluation + +The proposed solutions aim at resolving key issues KI SLC 1, SLC12,SLC13, SLC14 . + +## 6.10 Solution #9: Secure storage at rest + +### 6.10.1 Introduction + +Security log storage involves the safekeeping and retention of security logs for a certain period of time. It should ensure that all data security log event is retained reliably for a certain, defined, time so that no data is lost or altered, and that access to the data is restricted to authorized personnel only. + +### 6.10.2 Solution details + +The following are some key requirements for effective security log storage ([i.14] ): + +- Centralization: Security logs should be stored in a centralized location for easy management and analysis. This can be achieved through a centralized logging server or a cloud-based service. +- Tamper-proof: Security logs should be stored in a tamper-proof manner to ensure their integrity and authenticity. This can be achieved through digital signature, encryption, and hashing techniques. +- Retention: Retention policies should be established to determine how long logs should be kept. The retention period should be based on legal, regulatory, and compliance requirements, as well as the organization's own policies. +- Access Control: Access to the log storage should be restricted to authorized personnel only, and all access should be logged. +- Backup: Regular backups of the log storage should be performed and stored in a secure location, in case of data loss or corruption. +- Resource availability: it should be ensured that sufficient storage resources are always available in terms of both storage capacity and -bandwidth, in order to avoid data loss due to resource congestion. + +### 6.10.3 Evaluation + +This solution addresses key issue SLTM#1 of the present document. + +## 6.11 Solution #10: Secure transfer of logs + +### 6.11.1 Introduction + +Security log transfer involves the movement of security logs from one location to another, such as from a local device to a centralized logging server. + +### 6.11.2 Solution details + +#### 6.11.2.1 General + +The following are some key requirements for effective security log transfer ([i.14] ): + +- Confidentiality: Security logs should be confidentiality-protected during transfer to protect them from unauthorized access or tampering. +- Authentication: The parties involved in the log transfer should be authenticated to ensure that the logs are coming from a trusted source and going to a trusted destination. +- Integrity: Mechanisms should be in place to ensure the integrity of the logs during transfer, such as digital signatures or hash-based message authentication codes (HMACs). +- Non-repudiation: Logs transferred in bulk files should be digitally signed or otherwise marked in a way that prevents the sender from later denying having sent the logs. +- Auditing: The log transfer process should be auditable to enable the tracking and identification of any unauthorized or suspicious log transfers. + +#### 6.11.2.2 Recommendation of Syslog as a protocol to provide for security log streaming + +Syslog is a widely used de-facto standard for logging system events. It can be used to transfer security log events from devices such as routers, servers, and security appliances to a centralized logging server. RFC 5424 [i.36] defines the protocol which is used to convey the event notification messages and RFC 5425 [i.37] defines the transport mapping of syslog to TLS. + +The general recommendation is to use reliable syslog log event transfer using TCP, while utilizing TLS as the transport security layer. TLS should be used to provide: + +- Confidentiality protection ([i.37] , clause 3) +- Integrity protection ([i.37] , clause 3) +- Mutual authentication ([i.37] , clause 4.2.1) +- End-entity Certificate Based Authorization ([i.37] , clause 5.1) + +### 6.11.3 Evaluation + +This solution addresses key issue SLTM#3of the present document. + +## 6.12 Solution #11: Logging in O-RAN AI/ML systems + +### 6.12.1 Introduction + +There are several use cases that have been defined within O-RAN that will utilize some form of artificial intelligence and machine learning (AI/ML) [i.40][i.41]. Broadly the use cases address automation dealing with network management, beamforming, quality of service, resource optimization, and energy saving. As illustrated by [i.42] there are several threats and attacks pertaining to AI/ML. As part of a defence in depth security posture security logging within AI/ML systems is recommended. + +In addition to the ML Model itself, AI/ML systems are comprised of many different components. These components collectively are referred to as a ML pipeline. The pipeline deals with managing ML data, training the models and the lifecycle management of the trained models. The components of the ML pipeline reside in the Non-RT RIC, Near-RT RIC, O-CU, O-DU. The specific location of the ML components in the O-RAN architecture depend on the deployment scenario [42, Fig. 3: Deployment Scenarios]. + +There are several capabilities that an attacker can utilize against an AI/ML system as presented in [i.42]. Only a subset of attack capabilities lends themselves to an event that can be logged. Having this subset logged will provide valuable data for analytics that will indicate an AI/ML attack within O-RAN. For full coverage, other mitigations would need to be applied and that is out of scope for this technical report. + +The adversary events that can be logged are adversary accesses to score-based queries, decision-based queries, hyperparameters, training data, features data, raw data, sensor data, and labelled data. + +### 6.12.2 Solution details + +#### 6.12.2.1 AI/ML Workflow Comparison from general to specific + +A generalized ML pipeline has been proposed in [i.42] while [i.43] presents a ML pipeline that is specific to the O-RAN environment. Following is a mapping of the general ML pipeline in [i.42] to the O-RAN specific pipeline in [i.43]. This mapping will allow us to apply the threats enumerated in [i.42] to be applied to the O-RAN environment. + +**Table 6.12-1 - Pipeline components in reference [i.42] compared to reference [i.43].** + +| General ML Pipeline Component [i.42] | O-RAN Specific Pipeline Component [i.43] | +|--------------------------------------|------------------------------------------| +| Data Lake | Data Preparation | +| Data Host | | + +| | | +|----------------------|-------------------------------------------------------------------| +| Feature Store | Feature Engineering in the ML Training Host and ML Inference Host | +| Training Host | ML Training Host | +| Model Catalog | Model Management | +| Serving Host | ML Inference Host | +| ML-Assisted App Host | Actor & Action | + +The below figure depicts the AI/ML pipeline for O-RAN. It has been adapted from ([i.43], Figure 1) to include some coloring of blocks to relate a general pipeline presented in the O-RAN AML Threat Analysis [i.42]. In addition, the arrows that connect the boxes together have been labelled A through J. This is to assist in discussing what should be logged in the next clause. + +![Figure 6.12-1 - O-RAN AI/ML Workflow diagram. The diagram illustrates the AI/ML pipeline for O-RAN, showing the flow from data collection to model deployment and inference, with feedback loops for optimization. The pipeline is divided into several stages: Data Preparation, Model Training, Model Management, Model Inference, and Actor/Action. Key components include the ML Training Host, ML Inference Host, Model Management, and Actor. The diagram also shows the flow of data, model training info, model inference info, and model performance feedback. The bottom section shows the Continuous Operation phase, including Verification, Monitoring, Analysis, Recommendation, and Continue Optimization.](1c99badc8bc8417c196a2b65d28ed25b_img.jpg) + +The diagram illustrates the O-RAN AI/ML Workflow, showing the flow from data collection to model deployment and inference, with feedback loops for optimization. The pipeline is divided into several stages: + +- Data Collection:** Data from various sources (UE, O\_RU, O\_DU, O\_CU, CN, AF, OAM, Non-RT RIC, Near-RT RIC) is collected and processed (RAW Data). +- Data Preparation (A):** Data is prepared (Data Preparation, Data Ingestion/Data Selection, Data Fusion/Data Cleaning). +- Model Training (B):** Model training info is used to train the model (ML training host, Model Selection, Feature Engineering (Optional), Model Training & Testing, Model Optimization, Model Refine). +- Model Management (C):** Model training info is used to manage the model (Model Management, Certification/Onboarding, Deployment/Management/Termination). +- Model Inference (D):** Model inference info is used to infer the model (ML inference host, Feature Engineering (Optional), Model Inference Engine, ML Model inference, ML Model online learning). +- Actor/Action (E):** The Actor (UE O-DU, O-CU, RIC, Non-RT RIC) performs actions (Action) on the Subject of action (UE O-DU, O-CU, Non-RT RIC, Near-RT RIC). +- Feedback Loops (F, G, H, I, J):** Model performance feedback is used to optimize the model (Model performance feedback, Model inference host info, Model inference info, Model deployment/Termination, Model compiling info). +- Continuous Operation:** The workflow is continuously monitored and optimized (Verification, Monitoring, Analysis, Recommendation, Continue Optimization). + +Figure 6.12-1 - O-RAN AI/ML Workflow diagram. The diagram illustrates the AI/ML pipeline for O-RAN, showing the flow from data collection to model deployment and inference, with feedback loops for optimization. The pipeline is divided into several stages: Data Preparation, Model Training, Model Management, Model Inference, and Actor/Action. Key components include the ML Training Host, ML Inference Host, Model Management, and Actor. The diagram also shows the flow of data, model training info, model inference info, and model performance feedback. The bottom section shows the Continuous Operation phase, including Verification, Monitoring, Analysis, Recommendation, and Continue Optimization. + +Figure 6.12-1 - O-RAN AI/ML Workflow [i.43] + +#### 6.12.2.2 O-RAN AI/ML Workflow Description + +In the O-RAN AI/ML workflow specified in Figure 6.12-1 [i.43], a series of phases make up the workflow, starting with data collection and preparation and moving through model building, training, deployment, execution, validation, continuous self-monitoring, and self-learning/retraining. The ML Training host trains the model, while the Model Management host manages the ML models for deployment in the ML Inference host. Model compiling, which can be performed offline, optimizes the trained models for efficient execution and can be handled by the optional Model Compiling host. The compiled models are then published to the Model Management host for deployment to the ML Inference host, where the model is executed, and the Actor makes decisions. These hosts are network functions and depending on the deployment scenario for a particular O-RAN use case, can reside in either the Non-RT RIC, Near-RT RIC, or O-CU/O-DU. + +#### 6.12.2.3 O-RAN AI/ML Workflow Threats + +In the O-RAN AML Threat Analysis [i.42] there are several adversary attacks and threats that will produce events that can be logged. + +1. During an evasion or model extraction attack an adversary will repeatedly query a ML Model to recover probability vectors and classification labels ([i.42]: ACM1, ACM2). This adversary behaviour can be observed and correlated on *connections A, F and H*. +2. To facilitate evasion, poisoning, membership inference, data reconstruction, model corruption, or resource exhaustion attacks, an adversary will require knowledge about the internals of a model ([i.42], AKM1), such as model parameters, architecture, training time, and hyperparameters (e.g., the number of epochs and learning rate). All these assets should be considered sensitive information, and access to them should be logged. Model parameters reside in the ML Training Host, the ML Compiling Host, Model Inference Host, and the Model Management Host. In addition, model parameters also transit connections D, E and G. +3. With access to training and features data an adversary can corrupt ML models via poisoning attacks ([i.42], ACD1, ACD2). Training data should be considered sensitive information and access should be logged. Training data resides in the Data Preparation host and ML Training host and data transits *connection B*. +4. An adversary can carefully craft the data that is ingested into an ML system to facilitate several attacks pertaining to evasion, corruption, membership inference, data reconstruction, model extraction, and resource exhaustion ([i.42], ACD3, ACD4). However, other knowledge is required by the attacker to make use of this raw data. Logging raw data over *connection A* may not provide much value to a defender. Logging metadata over *connection A* may provide valuable data to enable correlation when developing analytics. It is worth noting that there are many sources of raw data with O-RAN. See Figure 6.12-1 in the Data box for the full list. +5. In general, there are several points within the ML pipeline that an adversary can gain access to data that is sensitive. The exposure of that information or changing of that data can lead to several undesirable impacts to the secure operation of the ML assisted application. Therefore, it is recommended that all reads and writes to any component in the ML pipeline (data preparation host, ML training host, model management host, ML compiling host, ML inference host) are logged. + +#### 6.12.2.4 AI/ML Logging Requirements + +This clause specifies the logging requirements to address the threats defined in the clause 6.12.2.3. + +1. Metadata on connections A, F and H should be logged. It is important that the metadata contain an identifier that makes it possible to correlate that data collected from the connections A, F and H. +2. All reads, writers or modifications to model parameters should be logged. Model parameters are stored on the ML Training Host, the ML Compiling Host, Model Inference Host, and the Model Management Host. +3. All reads, writes or modifications to training data or features data should be logged. This sensitive data resides on the Data Preparation host and the ML Training host. +4. Logging requirement for the Threat number 4 from the above clause 6.12.2.3 is covered by logging requirement number 1. +5. All accesses to the Data Preparation host, ML Training host, Model Management host, ML Compiling host, and ML Inference host should be logged. + +### 6.12.3 Evaluation + +This solution addresses key issue SLC#10 of the present document. + +## 6.13 Solution #12: Solution on preventing the tampering of log-Data + +### 6.13.1 Introduction + +The log files are the first artifacts that attackers will use to hide their actions. Therefore, the tampering of log-data should be prevented at first place. + +### 6.13.2 Solution details + +#### **Remote Logging / Replication:** + +A copy of the log-data (e.g., a security event) should be stored immediately inside the log-data-repository, i.e., at the point in time when log-data is to be stored local a copy should be created for the storage in the log-file-repository. + +Rationale: If the log-data is stored in a 'physically separate' memory space, the attacker, even if privileged, needs to obtain access to the log-data-repository. This can be seen as a second level of defense, i.e., the attacker obtains access to the cluster-node (1st level of defense) and thereafter needs to obtain access to the log-data-repository (2nd level of defense). + +#### **One-way communication:** + +The communication between the cluster-node and the log-data repository should be one-way, i.e., the log data transfer from the cluster node to the log-data-repository should be via an API (e.g., stdout). This API allows the cluster node to write log data to the log data repository and prevents the reading of log data. + +Rationale: If there is a One-way transfer of log-data, then there is no way for the attacker to obtain access to the cluster node and from there to obtain relevant information which is stored inside the log-file-repository. + +#### **Cryptographic Hash Chaining (Block Chaining):** + +The digest of log-data will be created and appended to existing and preceding digests with the aim to keep the cryptographic chain and to attest the completeness and the integrity of the security events. + +Rationale: If the attacker is removing at least one digest, then this is breaking the cryptographic chain. This Block-Chaining should be done over the log-file digest, just to save computational power. + +#### **Data Integrity using digital signatures:** + +This scheme utilizes asymmetric cryptography as well as hash function. Initially the digest of a log is obtained and is then signed by a private key. When a log is needed, the use of the public key and hash function ensure the integrity and authenticity of the log. + +#### **Limit access to log data repository:** + +Users should not have any access to log data repository unless some level of access is necessary for creating log entries. Additionally, users should not be able to rename, delete, or perform other operations on log data repository. + +### 6.13.3 Evaluation + +Remote logging ensures that log-data will be stored at different locations, and the hash chaining is providing some sort of book-keeping of security events. + +The one-way communication is hiding information. + +## 6.14 Solution #13: Security-related activities and events to be logged + +### 6.14.1 Introduction + +As explained in clause 5.2.1 multiple events originating from the network and application layers should be logged. In addition, it is recommended that events generated dealing with data access, accounts and identity, and security mechanisms are also logged. + +### 6.14.2 Solution details + +It is recommended to log the following events: + +**Table 6.14-1 Event categories to be logged** + +| Event Category | Description | +|---------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Network- and System Events | | +| Network connections | Network- related events such as:
  • port down/up incl. cause,
  • packets over limit from firewall
| +| Network configurations | Changes to network configurations | +| System configuration | Changes to system configuration | +| Resource usage | Resource-related events such as:
  • Shortages
  • system crashes
  • reboots
  • shutdowns
  • (virtual) Resource creation and -deletion
| +| System-wide events | System-wide events such as:
  • Startup
  • Shutdown
  • Restart
  • Crash
| +| Application-Layer events | | +| Lifecycle events | Lifecycle events such as:
  • service creation/deletion/stop/start
| +| Container and OS level administration services activities and executed commands | e.g. Build requests, Runtime commands | +| Image registry events | Image- registry related events such as:
  • additions
  • modifications
  • removal
| +| Lifecycle API calls | API calls related to the application lifecycle such as system calls
  • to deploy containers
  • discovery API
| +| Creation of scheduled jobs | Events of creation of scheduling of tasks (i.e. programs and scripts), to be executed e.g.
  • at a particular time
  • at startup
| +| Maintenance Activities | Maintenance activities undertaken | +| Account and Identity Events | | +| Authentication attempts | successful and unsuccessful authentication attempts, e.g.,
  • logon (including max retries alert)
  • logoff
| + +| Event Category | Description | +|--------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Change of account information | Successful and unsuccessful creation, modification, or deletion of user accounts or their privilege levels | +| Authorization Attempts | All successful and unsuccessful authorization attempts to create a session, initiate a transaction, or assume an elevated privilege | +| Termination of sessions, transactions, and downgrade in privileges | | +| Change of group memberships | Any change of group membership for accounts | +| Identity- and transaction- related events | Creation, modification, or deletion of identities; and transactions executed by users in applications | +| Anonymous requests | | +| Data Access Events | | +| Data access attempts | Successful and rejected system or data access attempts such as
  • • database queries
  • • read or writes to files
  • • read or writes to learning models
| +| File operations | The addition, deletion, or modification of files | +| File types | Types of files accessed | +| General Security Events | | +| Security logging | Starting and stopping of security logging | +| Security SW | Activation and deactivation of security software (e.g., malware protection, DLP or IDS). | +| Privilege | Use of privileged rights or powerful utilities | +| Cryptographic operations | | +| Security- related configuration | Any change to a security-related configuration item. The logged event must include the specifics of the configuration change | +| Accesses to personal data | Any access to personal data, including who accessed what data without revealing personal data in clear text. The logged event must include the specifics of the access | +| Master-Clock – related events | Any significant change to the configuration and performance of the PTP endpoint. The logged event must include the specifics of the change | +| Use of dynamically loaded libraries | Load events of dynamically loaded libraries. The logged event must include the name and version information of the library being loaded | +| O-Cloud- component- related events | | +| Vulnerable software | The presence or loading of known vulnerable software | +| App/VNF/CNF images | The deployment of suspicious or unknown App/VNF/CNF images in the O-Cloud platform | +| Interactions with images and VMs/Containers | Interactions with images and VMs/Containers by users to identify ones that are added or modified anomalously. | + +| Event Category | Description | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Escape attempts | Attempts to escape from a privileged VM/Container to the underlying host and hardware | +| Security patches | Security patches submitted, but not applied | +| Certificates and keys | Activities related to the management and use of certificates and keys installed in O-Cloud (e.g., TLS certificates and keys). such as
  • • view/list
  • • renew
  • • export
  • • import
  • • modify
  • • delete
| +| Cryptographic operations | All cryptographic operations on resources such as
  • • signature
  • • encryption/decryption
  • • hashing
  • • key generation
  • • key destruction.
| +| | | + +### 6.14.3 Evaluation + +This solution addresses key issue SLC#1-12, 14 and 16 of the present document. + +## 6.15 Solution #14: Log content: solution for harmonizing timestamps + +### 6.15.1 Introduction + +- Every security log event has a timestamp field to be populated +- Each product logs the security events with the timestamp information including the related timezone +- A possibility of harmonizing the timezones is required + +### 6.15.2 Solutions + +- The top-level log-aggregating component, usually a SIEM, adapts the timestamp a unique, the desired timezone after conversion and harmonisation +- E.g.: Component in the CU logs with timestamp UTC +2:00 and the Near-RT RIC located elsewhere we have UTC -1:00. Logs are transferred with the timestamp retained and converted to required format in the SIEM + +![Diagram illustrating timestamp adaptation in the SIEM. It shows a hierarchy of components: SIEM at the top, SMO in the middle, and CU/DU/RU at the bottom. SIEM receives timestamps from SMO and Near RT RIC, which in turn receive timestamps from CU/DU/RU. The timestamps are harmonized from various components to a single format.](2aec8738d5049d3aa40c1fd8f956b7f6_img.jpg) + +``` + +graph TD + SIEM[SIEM +Time stamp (harmonised from various components to single format)] + SMO[SMO +Component 1 Timestamp GMT +Component n Timestamp GMT] + Near_RT_RIC[Near RT RIC +Component 1 Timestamp UTC -1:00 +Component 1 Timestamp UTC +1:00] + CU_DU_RU[CU/DU/RU +Component 1 Timestamp UTC +2:00 +Component 1 Timestamp UTC +2:00] + + SIEM <--> SMO + SIEM <--> Near_RT_RIC + SMO <--> Near_RT_RIC + Near_RT_RIC <--> CU_DU_RU + +``` + +Diagram illustrating timestamp adaptation in the SIEM. It shows a hierarchy of components: SIEM at the top, SMO in the middle, and CU/DU/RU at the bottom. SIEM receives timestamps from SMO and Near RT RIC, which in turn receive timestamps from CU/DU/RU. The timestamps are harmonized from various components to a single format. + +**Figure 6.15-1 Example of timestamp-adaptation in the SIEM** + +### 6.15.3 Evaluation + +The proposed solutions aim at resolving key issue SLF#2 + +## 6.16 Solution #15: Solution on Logs Using Common Time Sources + +### 6.16.1 Introduction + +This solution suggests the support of common time sources for logging. + +### 6.16.2 Solution Details + +The logs should be time-stamped with common time source, typically NTP and/or GNSS should be supported. If NTP and GNSS are not available, then the IEEE 1588 [i.47] might be an option. + +If the common time source is missing, then the usage of system time should be indicated in Log-data. + +If the common time source is missing, then the log entry should be time-stamped with the current system time. + +If the common time source is missing, then the order of the log entries should be kept as the (security) log events occur. + +The timestamp representation should be in a standard format, and the used formatting profile should be logged. Reference to RFC 3339 [i.46] and ISO 8601 [i.48]. + +If the system time cannot be synchronized with any common time source, then the system should time stamp any log entry with the available system time. + +NOTE: The system time is not the same as the local time. Although the usage of a ‘Unqualified Local Time’ is somewhat unwanted, the log entries should be time-stamped while the system attempts to synchronize with UTC. + +The successful synchronization to UTC should be logged. + +### 6.16.3 Evaluation + +This log support using common time sources is relevant for systems producing multiple log streams, though, the timestamps play a critical role in correlating entries across streams and in deriving a global order. The systems should use different mechanisms for synchronization to UTC. + +This solution is solving the key issue SLC#14. + +## 6.17 Solution #16: Availability of Logging: Solution for ensuring logging reliability + +### 6.17.1 Introduction + +As articulated in clause 5.3.4.2, there are significant challenges to achieving logging reliability. This clause is dedicated to providing an optional capability to address logging reliability problems via the addition of the Reliable Event Logging Protocol (RELP). + +### 6.17.2 Solutions + +- Reliable Event Logging Protocol (RELP) extends the functionality of the syslog protocol to provide reliable delivery of event messages. RELP does not as yet have a dedicated RFC, but it is inspired by RFC 3080 [i.53] and RFC 3195 [i.54]. +- RELP offers a backchannel and message receipt tracking to ensure that syslog is aware of which logs have been received correctly. +- RELP supports TLS which shall be enabled to ensure confidentiality, integrity and mutual authentication. + +### 6.17.3 Evaluation + +The proposed solutions aim at resolving key issue SLTM#4. + +# 7 Conclusions + +## 7.1 Key Issue Solution Mapping + +### 7.1.1 Security logs contents + +This document currently contains 16 key issues (SLC#1 to SLC#16) related to Security log contents (Key issue SLC #15 being void) and 3 solution proposals (Sol#8, Sol#13 and Sol#15) to address or reduce the risk associated with the key issues. A mapping of the solutions to the key issues is shown here. + +**Table 7.1-1 Key Issue Solution mapping for Security logs contents** + +| Key issue | Sol # 1 | Soln #2 | Sol #3 | Sol #4 | Sol #5 | Sol #6 | Sol #7 | Sol #8 | Sol #9 | Sol #10 | Sol #11 | Sol #12 | Sol #13 | Sol #14 | Sol #15 | Sol #16 | +|-----------|---------|---------|--------|--------|--------|--------|--------|--------|--------|---------|---------|---------|---------|---------|---------|---------| +| SLC#1 | | | | | | | | X | | | | | X | | | | + +| Key
issue | Sol
# 1 | Soln
#2 | Sol
#3 | Sol
#4 | Sol
#5 | Sol
#6 | Sol
#7 | Sol
#8 | Sol
#9 | Sol
#10 | Sol
#11 | Sol
#12 | Sol
#13 | Sol
#14 | Sol
#15 | Sol
#16 | +|--------------------------|------------|------------|-----------|-----------|-----------|-----------|-----------|-----------|-----------|------------|------------|------------|------------|------------|------------|------------| +| SLC#2 | | | | | | | | | | | | | X | | | | +| SLC#3 | | | | | | | | | | | | | X | | | | +| SLC#4 | | | | | | | | | | | | | X | | | | +| SLC#5 | | | | | | | | | | | | | X | | | | +| SLC#6 | | | | | | | | | | | | | X | | | | +| SLC#7 | | | | | | | | | | | | | X | | | | +| SLC#8 | | | | | | | | | | | | | X | | | | +| SLC#9 | | | | | | | | | | | | | X | | | | +| SLC#10 | | | | | | | | | | | X | | X | | | | +| SLC#11 | | | | | | | | | | | | | X | | | | +| SLC#12 | | | | | | | | X | | | | | X | | | | +| SLC#13 | | | | | | | | X | | | | | | | | | +| SLC#14 | | | | | | | | X | | | | | X | | X | | +| SLC#15
(void)
| | | | | | | | | | | | | | | | | +| SLC#16 | | | | | | | | | | | | | X | | | | + +### 7.1.2 Security logs transfer mechanisms + +This document currently contains 4 key issues (SLTM#1 to SLTM#4) related to Security log transfer mechanism and 4 solution proposals (Sol#6, Sol#9, Sol#10 and Sol#16) to address or reduce the risk associated with the key issues. A mapping of the solutions to the key issues is shown here. + +**Table 7.1-2 Key Issue Solution mapping for Security logs transfer mechanisms** + +| Key issue | Sol # 1 | Soln #2 | Sol #3 | Sol #4 | Sol #5 | Sol #6 | Sol #7 | Sol #8 | Sol #9 | Sol #10 | Sol #11 | Sol #12 | Sol #13 | Sol #14 | Sol #15 | Sol #16 | +|-----------|---------|---------|--------|--------|--------|--------|--------|--------|--------|---------|---------|---------|---------|---------|---------|---------| +| SLTM#1 | | | | | | | | | X | | | | | | | | +| SLTM#2 | | | | | | | | | X | | | | | | | | +| SLTM#3 | | | | | | | | | | X | | | | | | | +| SLTM#4 | | | | | | X | | | X | | | | | | | X | + +### 7.1.3 Security logs formats + +This document currently contains 3 key issues (SLF#1 to SLF#3) related to Security logs formats and 2 solution proposals (Sol#7 and Sol#14) to address or reduce the risk associated with the key issues. A mapping of the solutions to the key issues is shown here. + +**Table 7.1-3 Key Issue Solution mapping for Security logs formats** + +| Key issue | Sol # 1 | Soln #2 | Sol #3 | Sol #4 | Sol #5 | Sol #6 | Sol #7 | Sol #8 | Sol #9 | Sol #10 | Sol #11 | Sol #12 | Sol #13 | Sol #14 | Sol #15 | Sol #16 | +|-----------|---------|---------|--------|--------|--------|--------|--------|--------|--------|---------|---------|---------|---------|---------|---------|---------| +| SLF#1 | | | | | | | X | | | | | | | | | | +| SLF#2 | | | | | | | X | | | | | | | X | | | +| SLF#3 | | | | | | | X | | | | | | | | | | + +### 7.1.4 Log Management Security Framework + +This document currently contains 7 key issues (LMSF#1 to LMSF#7) related to Log Management Security Framework and 7 solution proposals (Sol#1, Sol#2, Sol#3, Sol#4, Sol#5, Sol#6 and Sol#12) to address or reduce the risk associated with the key issues. A mapping of the solutions to the key issues is shown here. + +**Table 7.1-4 Key Issue Solution mapping for Log Management Security Framework** + +| Key issue | Sol # 1 | Soln #2 | Sol #3 | Sol #4 | Sol #5 | Sol #6 | Sol #7 | Sol #8 | Sol #9 | Sol #10 | Sol #11 | Sol #12 | Sol #13 | Sol #14 | Sol #15 | Sol #16 | +|-----------|---------|---------|--------|--------|--------|--------|--------|--------|--------|---------|---------|---------|---------|---------|---------|---------| +| LMSF#1 | X | | | | | | | | | | | | | | | | +| LMSF#2 | | X | | | | | | | | | | | | | | | +| LMSF#3 | | | X | | | | | | | | | | | | | | +| LMSF#4 | | | | X | | | | | | | | | | | | | +| LMSF#5 | | | | | | | | | | | | X | | | | | +| LMSF#6 | | | | | X | | | | | | | | | | | | +| LMSF#7 | | | | | | X | | | | | | | | | | | + +## 7.2 Alignment to other studies + +### 7.2.1 Application Lifecycle Management Security + +The Application Lifecycle Management Security Work Item in WG11 identified security threats that could be detected by logging application life cycle events and recommended a set of application life cycle events for security logging in the technical report “Study on Security for Application Life Cycle Management” [i.30]. This list of events may be used to develop security analytics that have the potential to detect anomalous behaviour. These events were mapped to Key Issue SLC#1 Logging Security Related Activity and Events in order to ensure coverage of these events, and Key Issue SLC#1 was updated to account for missing application life cycle logging events. + +Table 7.2-1 shows this mapping of specific application LCM events to the categories described in Key Issue SLC#1 to show coverage of the application events. + +**Table 7.2-1 - Application LCM Logging Events** + +| AppLCMsec TR KI Op-3
Application LCM Event | Security Log Management TR KI SLC#1
Security Logging event | +|-----------------------------------------------|---------------------------------------------------------------| +| Cryptographic hash of application package | 5d: Cryptographic operations | +| Onboarding of application packages | 2c: Image registry events, addition | +| Instantiation of application packages | 2a: Lifecycle events, service creation | +| Creation of app IDs (for x/rApps) | 3f: Creation of identities | + +| | | +|-------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------| +| Changes to application configuration | 2g: Change notifications | +| Updates to applications | 2f: Maintenance activity undertaken
2g: Change notifications | +| Creation, modification, or deletion of identities; and transactions executed by users in applications | 3f: Creation, modification, or deletion of identities; and transactions executed by users in applications. | +| Application resource usage (disk space, CPU load) | 1c: Resource usage | +| Decommissioning of applications | 2a: Lifecycle events, service deletion | +| Application API calls | 2d: API calls | + +# 8 Recommendations + +This is a list of recommendations on next steps to be done on the contents of the present document in future revisions and on other O-RAN specifications based on the current state of this document. + +**Recommendation 1:** This work item should contribute to the WG11 Security Requirements specifications [i.2] with new requirements and security controls from the solutions outlined in this report. CRs will be generated as required. + +**Recommendation 2:** This work item should contribute security test cases for relevant security requirements to the WG11 Security Test specification [i.45]. CRs will be generated as required. + +**Recommendation 3:** This work item should contribute to the WG11 Security Protocols specifications [i.3] with new protocol- related requirements and controls from the solutions outlined in this report. CRs will be generated as required. + +**Recommendation 4:** This work item should contribute to the WG11 O- Security Threat Modeling and Remediation Analysis [i.1] with new threats and risks from the key issues outlined in this report. CRs will be generated as required. + +**Recommendation 5:** WG11 should collaborate with WG4 and WG10 to ensure the WG11 security specifications are appropriately referenced by WG4 and WG10 in their specifications. + +**Recommendation 6:** the following diagram represents a possible structure to carry out log management. O-RAN does not define any such structure. + +![Figure 8-1: An example Security Log Management Schema. The diagram shows a central 'Central Logs repository' (SMO) connected to various O-RAN components. The SMO is connected to O-DU, O-CU, Near RT RIC, and O-Cloud via O1 interfaces. O-DU is connected to O-RU#1 and O-RU#2 via FH M-Plane. Near RT RIC is connected to xApp #1 and xApp #n via REST API. O-Cloud is connected to the SMO via O2 interface. A SIEM system is connected to the Central Logs repository. Log storage is indicated by blue cylinder icons.](693da3ba03e0bad52e214d32d001592d_img.jpg) + +Figure 8-1 illustrates a Security Log Management Schema. The central component is the SMO (Service Management Orchestrator), which acts as the Central Logs repository. It is connected to various O-RAN components via O1 interfaces: O-DU (Distributed Unit), O-CU (Central Unit), Near RT RIC (Near Real Time RIC), and O-Cloud. O-DU is further connected to O-RU#1 and O-RU#2 (Radio Units) via the FH M-Plane (Fronthaul Multi-Plane). Near RT RIC is connected to xApp #1 and xApp #n (Applications) via REST API. O-Cloud is connected to the SMO via O2 interface. A SIEM (Security Information and Event Management) system is connected to the Central Logs repository. Log storage is indicated by blue cylinder icons. + +Figure 8-1: An example Security Log Management Schema. The diagram shows a central 'Central Logs repository' (SMO) connected to various O-RAN components. The SMO is connected to O-DU, O-CU, Near RT RIC, and O-Cloud via O1 interfaces. O-DU is connected to O-RU#1 and O-RU#2 via FH M-Plane. Near RT RIC is connected to xApp #1 and xApp #n via REST API. O-Cloud is connected to the SMO via O2 interface. A SIEM system is connected to the Central Logs repository. Log storage is indicated by blue cylinder icons. + +Figure 8-1 An example Security Log Management Schema + +# Annex: Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|-----------------------------------| +| 11/8/2022 | v01.00 | Version 1 of the Technical Report | +| 23/02/2023 | v02.00 | Version 2 of the Technical Report | +| 20/07/2023 | V03.00 | Version 3 of the Technical Report | +| 22/11/2023 | V04.00 | Version 4 of the Technical Report | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/04001b31b76b02392fb8f58a556bf181_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/04001b31b76b02392fb8f58a556bf181_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9db8bcf5b7950be2197e9560a0529e8af517fd7b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/04001b31b76b02392fb8f58a556bf181_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5ccf8b8c9e5ab81c24388f9ce851a7fb94ca875019e7215a1e36c047778c20c5 +size 48980 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/23872d06c8f12d9f68ca94b03a5275cc_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/23872d06c8f12d9f68ca94b03a5275cc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cdf6e81e3b62244e3fe5d11c4dbb2a1e36bb738d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/23872d06c8f12d9f68ca94b03a5275cc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f4ef8a5ea0cb6544d2477cffbb9c7126895b1828133ab49cc2f681799b503edf +size 148056 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/27927bdca1769fed46cae1d4c94911d3_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/27927bdca1769fed46cae1d4c94911d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7818976192424d6f6181d6b8994ac2a731c30947 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/27927bdca1769fed46cae1d4c94911d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e7d986ae605e9d91e06fad52081b38815f7d1297de5920dcc02b45958c590719 +size 77517 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/2c78150856ba0875e8a096304863b445_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/2c78150856ba0875e8a096304863b445_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5697e2763496cd012eecee2826bc598cb255767d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/2c78150856ba0875e8a096304863b445_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1f90017fedbeadb235dcb35ad3391d82699cabd970f84a79224a82fa7c50e431 +size 152921 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/46b7ee71831dd713ce8b69a688db5ede_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/46b7ee71831dd713ce8b69a688db5ede_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cfd5596f7d87ee257cd1d18a519d12b55c3eaad4 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/46b7ee71831dd713ce8b69a688db5ede_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4a809033142b564e85ead961f926fa55c7b67a48dc041f868974003070e5dd9c +size 58400 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/4ff48b1304b701cbb54dcd647087433e_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/4ff48b1304b701cbb54dcd647087433e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..97816b1a2d2a24207f9f0f58961da7bc33f599d7 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/4ff48b1304b701cbb54dcd647087433e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6f2762594fa0c5c304c3d5df2aafb76a0849a39f1a5060c59db4ec99abd4f1e1 +size 36387 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/5b23be1d8dbd70670a8f63f10723f1f5_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/5b23be1d8dbd70670a8f63f10723f1f5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1daeef2a8dd07b2d124f931b5f07314577cdf256 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/5b23be1d8dbd70670a8f63f10723f1f5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ff17a95e0404c9bf20843f48be04cc36fac00e6e3fc1c8de83b0b0eb1c424f96 +size 89024 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/7aef642d0e825a1a9c1f1442f9dd80dc_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/7aef642d0e825a1a9c1f1442f9dd80dc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..09d91d4fd0d669006ce543f7b1e102839ddea971 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/7aef642d0e825a1a9c1f1442f9dd80dc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:083e921ddec654e0365f94edb7bec9d47bb0f33880b9f8c94442f3109cb769e7 +size 43297 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/87e79467a06d61dd357b91ea09704de3_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/87e79467a06d61dd357b91ea09704de3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..af8bec61b50a860a4c6493bf7d6858d1a07079d2 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/87e79467a06d61dd357b91ea09704de3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cb26237f407d5eeeacbf064ee6a5dc5b21caa632b21588387c36439bade2bd1a +size 50359 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/8a910c57c57a6a28ed284fe42f95e548_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/8a910c57c57a6a28ed284fe42f95e548_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ea1f4c0d2d8715b7fd512f67fc3b16ea4fdeb64c --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/8a910c57c57a6a28ed284fe42f95e548_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ce1b5b93ca0f17d9a8b990b810407ad35623c585936e45c971255d4499c93fc +size 101579 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/a14f0c7149401d7ad3abd09fee0b1f1f_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/a14f0c7149401d7ad3abd09fee0b1f1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ce770952108b312fd90a73c14c3c1a7ba6655076 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/a14f0c7149401d7ad3abd09fee0b1f1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7415cd6b5a029ef0c22e53d635a5f8d578df17202b404f1fc77225912c20c624 +size 61122 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/b3687f908deff19754c146afdccd390f_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/b3687f908deff19754c146afdccd390f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c7f89372906dd85dc53d9a90ae5a098aa8e49f7e --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/b3687f908deff19754c146afdccd390f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:daf9f7f83a95312afaef69bccc82c31335a6c5553e3c53aafabafb8714ec6804 +size 13020 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d73ac8b8be38faf362b1eaa59fff1f3f167364fb --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3276e59412020445a9dbac9cf2ede064a279427afdcaa0dcf94fa0620d916726 +size 4546 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2607b0eef27677fb38e9fdbba214fde5d86a7f72 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9e383e92647a2356488a833110e26ad296a5dd136dd01f365e78a67474a8258 +size 4548 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/ed531c361515dbdc198449009c8b2d7c_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/ed531c361515dbdc198449009c8b2d7c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0835a6fe8b3d1724f873e0c4364b471d9536be8a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/ed531c361515dbdc198449009c8b2d7c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2749273a1e979a9b63357c46170ade32e2c88b206bd7f0fc8c08fbc7f67891ae +size 4561 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/ef605bb5673c8838aa537ba1342af1d6_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/ef605bb5673c8838aa537ba1342af1d6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..33ed48164ce2f7044305b7bdb51a542ceba88262 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/ef605bb5673c8838aa537ba1342af1d6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6cc11c1cc8ccd99725af7ed6e9f71e73446877d474409eb183204d06724626f7 +size 38795 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/f705517b50a73bc3abd6880a25451c55_img.jpg b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/f705517b50a73bc3abd6880a25451c55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c75f01124494feaf87798aa623e5e581d1c8df9f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/f705517b50a73bc3abd6880a25451c55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:883ad84325b05f0806e8fcac747a755f84bcb5b4125d040a0f1963086cdbf572 +size 50964 diff --git a/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/raw.md b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..b1823ca0abb4d29e28c2b44413ed804d59dddf31 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00/raw.md @@ -0,0 +1,1957 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)** + +# **Study on Security for Near Real Time RIC and xApps** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +# --- Contents + +| | | +|-----------------------------------------------------------------------------|----| +| Foreword ..... | 5 | +| Modal verbs terminology ..... | 5 | +| Introduction ..... | 5 | +| 1 Scope..... | 6 | +| 2 References..... | 6 | +| 2.1 Informative references..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 8 | +| 3.1 Terms..... | 8 | +| 3.2 Symbols..... | 9 | +| 3.3 Abbreviations ..... | 9 | +| 4 RIC background, concepts and assumptions..... | 12 | +| 4.1 Introduction ..... | 12 | +| 4.2 Near-RT RIC architecture ..... | 12 | +| 4.3 Interfaces ..... | 13 | +| 4.4 xApps ..... | 13 | +| 4.5 Near-RT RIC APIs..... | 14 | +| 5 Key Issues ..... | 15 | +| 5.1 Introduction ..... | 15 | +| 5.2 Key Issue #1: Malicious xApps deployed on the Near-RT RIC ..... | 16 | +| 5.2.1 Key issue detail..... | 16 | +| 5.2.2 Security threats ..... | 16 | +| 5.2.3 Potential security requirements ..... | 16 | +| 5.3 Key Issue #2: Compromised xApp ..... | 16 | +| 5.3.1 Key issue detail..... | 16 | +| 5.3.2 Security Threats..... | 17 | +| 5.3.3 Potential security requirements ..... | 17 | +| 5.4 Key Issue #3: Conflicting xApps ..... | 17 | +| 5.4.1 Key issue detail..... | 17 | +| 5.4.2 Security threats ..... | 18 | +| 5.4.3 Potential security requirements ..... | 18 | +| 5.5 Key Issue #4: Isolation between xApps ..... | 18 | +| 5.5.1 Key issue detail..... | 18 | +| 5.5.2 Security threats ..... | 18 | +| 5.5.3 Potential security requirements ..... | 19 | +| 5.6 Key Issue #5: Compromise of ML data pipelines used in Near-RT RIC ..... | 19 | +| 5.6.1 Key issue detail..... | 19 | +| 5.6.2 Security threats ..... | 19 | +| 5.6.3 Potential security requirements ..... | 20 | +| 5.7 Key Issue #6: Altering the ML learning models used in Near-RT RIC..... | 20 | +| 5.7.1 Key issue detail..... | 20 | +| 5.7.2 Security threats ..... | 21 | +| 5.7.3 Potential security requirements ..... | 21 | +| 5.8 Key Issue #7: Data Protection and Privacy in Near-RT RIC Database ..... | 21 | +| 5.8.1 Key issue detail..... | 21 | +| 5.8.2 Security threats ..... | 21 | +| 5.8.3 Potential security requirements ..... | 22 | +| 5.9 Key Issue #8: Onboarding untrusted xApps ..... | 22 | +| 5.9.1 Key issue detail..... | 22 | +| 5.9.2 Security threats ..... | 22 | +| 5.9.3 Potential security requirements ..... | 23 | +| 5.10 Key Issue #9: xApp exploitation via malicious A1 policies ..... | 23 | +| 5.10.1 Key issue detail..... | 23 | + +| | | | +|--------|-------------------------------------------------------------------------------------------------------|----| +| 5.10.2 | Security threats ..... | 23 | +| 5.10.3 | Potential security requirements ..... | 23 | +| 5.11 | Key Issue #10: Near-RT RIC APIs authentication ..... | 24 | +| 5.11.1 | Key issue detail..... | 24 | +| 5.11.2 | Security threats ..... | 24 | +| 5.11.3 | Potential security requirements ..... | 25 | +| 5.12 | Key Issue #11: Near-RT RIC APIs authorization..... | 25 | +| 5.12.1 | Key issue detail..... | 25 | +| 5.12.2 | Security threats ..... | 26 | +| 5.12.3 | Potential security requirements ..... | 26 | +| 5.13 | Key Issue #12: xAppID abuse..... | 26 | +| 5.13.1 | Key issue detail..... | 26 | +| 5.13.2 | Security threats ..... | 26 | +| 5.13.3 | Potential security requirements ..... | 27 | +| 5.14 | Key Issue #13: Malicious Y1 Consumer..... | 27 | +| 5.14.1 | Key issue detail..... | 27 | +| 5.14.2 | Security threats ..... | 27 | +| 5.14.3 | Potential security requirements ..... | 27 | +| 5.15 | Key Issue #14: Malicious E2 Node..... | 28 | +| 5.15.1 | Key issue detail..... | 28 | +| 5.15.2 | Security threats ..... | 28 | +| 5.15.3 | Potential security requirements ..... | 28 | +| 6 | Mitigations and Solutions ..... | 29 | +| 6.1 | Introduction ..... | 29 | +| 6.2 | Solution #1: Secure onboarding and deployment of xApps in Near-RT RIC..... | 29 | +| 6.2.1 | Introduction ..... | 29 | +| 6.2.2 | Solution details ..... | 29 | +| 6.2.3 | Evaluation..... | 31 | +| 6.3 | Solution #2: Security management of risks in open-source components of Near-RT RIC architecture ..... | 31 | +| 6.3.1 | Introduction ..... | 31 | +| 6.3.2 | Solution details ..... | 32 | +| 6.3.3 | Evaluation..... | 34 | +| 6.4 | Solution #3: Authentication schema for APIs..... | 34 | +| 6.4.1 | Introduction ..... | 34 | +| 6.4.2 | Solution details ..... | 35 | +| 6.4.3 | Evaluation..... | 36 | +| 6.5 | Solution #4: Authorization framework for APIs..... | 36 | +| 6.5.1 | Introduction ..... | 36 | +| 6.5.2 | Solution details ..... | 36 | +| 6.5.3 | Evaluation..... | 38 | +| 6.6 | Solution #5: Near-RT RIC database and SDL access control mechanisms..... | 38 | +| 6.6.1 | Introduction ..... | 38 | +| 6.6.2 | Solution details ..... | 38 | +| 6.6.3 | Evaluation..... | 39 | +| 6.7 | Solution #6: Security Logging (part of FCAPS)..... | 40 | +| 6.7.1 | Introduction ..... | 40 | +| 6.7.2 | Solution details ..... | 40 | +| 6.7.3 | Evaluation..... | 40 | +| 6.8 | Solution #7: Access control mechanism for API repository/registry..... | 40 | +| 6.8.1 | Introduction ..... | 40 | +| 6.8.2 | Solution details ..... | 41 | +| 6.8.3 | Evaluation..... | 41 | +| 6.9 | Solution #8: Secure mechanisms for E2 interface ..... | 41 | +| 6.9.1 | Introduction ..... | 41 | +| 6.9.2 | Solution details ..... | 41 | +| 6.9.3 | Evaluation..... | 41 | +| 6.10 | Solution #9: Secure mechanisms for A1 interface ..... | 41 | +| 6.10.1 | Introduction ..... | 41 | +| 6.10.2 | Solution details ..... | 42 | +| 6.10.3 | Evaluation..... | 42 | + +| | | | +|--------|---------------------------------------------------------------------------------------------|----| +| 6.11 | Solution #10: Secure mechanisms for O1 interface ..... | 42 | +| 6.11.1 | Introduction ..... | 42 | +| 6.11.2 | Solution details ..... | 42 | +| 6.11.3 | Evaluation ..... | 42 | +| 6.12 | Solution #11: Mitigation for conflicting xApps ..... | 42 | +| 6.12.1 | Introduction ..... | 42 | +| 6.12.2 | Solution details ..... | 43 | +| 6.12.3 | Evaluation ..... | 43 | +| 6.13 | Solution #12: A1 Policy authentication ..... | 43 | +| 6.13.1 | Introduction ..... | 43 | +| 6.13.2 | Solution details ..... | 43 | +| 6.13.3 | Evaluation ..... | 44 | +| 6.14 | Solution #13: Network Security layer for APIs ..... | 44 | +| 6.14.1 | Introduction ..... | 44 | +| 6.14.2 | Solution details ..... | 44 | +| 6.14.3 | Evaluation ..... | 45 | +| 6.15 | Solution #14: Security procedure for xApp registration ..... | 45 | +| 6.15.1 | Introduction ..... | 45 | +| 6.15.2 | Solution details ..... | 45 | +| 6.15.3 | Evaluation ..... | 48 | +| 6.16 | Solution #15: Security requirement proposals for Y1 interface ..... | 49 | +| 6.16.1 | Introduction ..... | 49 | +| 6.16.2 | Solution details ..... | 50 | +| 6.16.3 | Evaluation ..... | 50 | +| 6.17 | Solution #16: Additional security measures for the E2 interface ..... | 51 | +| 6.17.1 | Introduction ..... | 51 | +| 6.17.2 | Solution details ..... | 51 | +| 6.17.3 | Evaluation ..... | 51 | +| 6.18 | Solution #17: Standard Identity management of xApp during xApp Registration Procedure ..... | 51 | +| 6.18.1 | Introduction ..... | 51 | +| 6.18.2 | Solution details ..... | 52 | +| 6.18.3 | Evaluation ..... | 55 | +| 7. | Conclusions ..... | 56 | +| 7.1 | Key Issue Solution Mapping ..... | 56 | +| 8. | Recommendations ..... | 57 | +| | History ..... | 58 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +--- + +## Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Introduction + +The Near-Real Time RAN Intelligent Controller (Near-RT RIC) is a new virtualized function that adds RAN programmability to existing or new RAN networks, e.g., self-organizing networks (SON) type of functions. It is a platform designed to use AI/ML-based tools with open interfaces to the RAN (E2) and the management and orchestration system (A1, O1). + +The Near-RT RIC enables near real time control and optimization of RAN elements and resources via fine-grained data (e.g., UE basis, Cell basis) collection and actions over E2 interface, and includes open interfaces (A1, O1) to the management and orchestration system (SMO). + +The Near-RT RIC platform is a software-based near-real-time microservice-based platform for hosting microservice-based applications – the xApps – that run on the Near-RT RIC platform. A xApp may consist of one or more microservices and at the point of onboarding it identifies which data it consumes and which data it provides. It is independent of Near-RT RIC and may be provided by any third party. The E2 interface enables a direct association between xApp and RAN functionalities. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +Yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +Zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document considers the security aspects of the Near-RT RIC platform and xApps, as well as the associated network and management interfaces (E2, A1, O1) and APIs. + +Taking into consideration the threats and risks identified in O-RAN Threat Model specification [1], the study analyses a list of key issues in the Near-RT RIC overall architecture and proposes solutions in order to derive security requirements, intended to be part of O-RAN Security Requirements Specifications [2]. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +[1] O-RAN ALLIANCE TR: “O-RAN Security Threat Modeling and Risk Assessment” + +[2] O-RAN ALLIANCE TS: “Security Requirements and Controls Specification” + +[3] O-RAN ALLIANCE TS: “Near-RT RIC Architecture ” + +[4] O-RAN ALLIANCE TS: “Non-RT RIC and A1 Interface Use Cases and Requirements ” + +[5] O-RAN ALLIANCE TS: “E2 General Aspects and Principles (E2GAP)” + +[6] O-RAN ALLIANCE TS: “O1 Interface specification for O-DU” + +- [7] O-RAN ALLIANCE TS: “O1 Interface specification for O-CU-UP and O-CU-CP” +- [8] O-RAN ALLIANCE TS: “O-RAN Operations and Maintenance Interface Specification (O1)” +- [9] O-RAN ALLIANCE TS: “A1 interface: General Aspects and Principles” +- [10] OWASP API Security Top 10 2019. +- [11] RFC 6749: The OAuth 2.0 Authentication framework. +- [12] RFC 6819: OAuth 2.0 threat model and security considerations. +- [13] 3GPP TS 33.501: “Security architecture and procedures for 5G system” +- [14] ETSI NFV SEC022: “Network Functions Virtualization (NFV) Release 2; Security; Access Token Specification for API Access”. +- [15] ETSI GS MEC 009 V3.1.1 (2021-06): Multi-access Edge Computing (MEC); General principles, patterns and common aspects of MEC Service APIs. [https://www.etsi.org/deliver/etsi\\_gs/MEC/001\\_099/009/03.01.01\\_60/gs\\_MEC009v030101p.pdf](https://www.etsi.org/deliver/etsi_gs/MEC/001_099/009/03.01.01_60/gs_MEC009v030101p.pdf) +- [16] 3GPP TR 33.845 v16.1.0 (2020-09): Study on security aspects of the 5G Service Based Architecture (SBA) +- [17] RFC 7519: JSON Web Token. +- [18] RFC 7515: JSON Web Signature. +- [19] O-RAN ALLIANCE TS: “Security Protocols Specifications” +- [20] 3GPP TS 33.310: “Network Domain Security (NDS); Authentication Framework (AF)”. +- [21] 3GPP TS 33.210: “3G security; Network Domain Security (NDS); IP network layer security”. +- [22] O-RAN ALLIANCE TS: “O-RAN Operations and Maintenance Architecture” +- [23] O-RAN ALLIANCE TS, “O-RAN Orchestration Use Cases and Requirements for O-RAN Virtualized RAN” +- [24] Executive Order 14028, Improving the Nation’s Cybersecurity: Security Measures for EO-Critical Software Use. +- [25] OpenSSF Best Practices. +- [26] OpenSSF Software Development Fundamentals Link: +- [27] OpenSSF Best Practices Badge Program: +- [28] CISA NSA 5G Security guideline [https://media.defense.gov/2021/Oct/28/2002881720/-1/-1/0/SECURITY\\_GUIDANCE\\_FOR\\_5G\\_CLOUD\\_INFRASTRUCTURES\\_PART\\_I\\_20211028.PDF](https://media.defense.gov/2021/Oct/28/2002881720/-1/-1/0/SECURITY_GUIDANCE_FOR_5G_CLOUD_INFRASTRUCTURES_PART_I_20211028.PDF) +- [29] Opensource Software “Security 5G Security” whitepaper. +- [30] NIST Special Publication (SP) 800-40, Guide to Enterprise Patch Management Technologies. +- [31] 3GPP TS 33.122: “Security aspects of Common API Framework (CAPIF) for 3GPP northbound APIs” +- [32] O-RAN ALLIANCE TS: “O-RAN Architecture Description” + +- [33] 3GPP TS 23.501: “System Architecture for the 5G System (5GS); Stage 2”. +- [34] RAIE Impacts on Near-RT RIC Architecture; discussion document, [CMCC-2022.12.12-WG3-C-RAIE Impacts on RICARCH-v2.pptx](#) +- [35] Solving the Bottom Turtle — a SPIFFE Way to Establish Trust in Your Infrastructure via Universal Identity: +- [36] SPIRE Concepts: An overview of SPIRE’s architecture and fundamentals: +- [37] Kubernetes Documentation: PKI certificates and requirements: +- [38] Plugin\_agent\_workloadattestor\_k8s: [https://github.com/spiffe/spire/blob/v1.7.0/doc/plugin\\_agent\\_workloadattestor\\_k8s.md](https://github.com/spiffe/spire/blob/v1.7.0/doc/plugin_agent_workloadattestor_k8s.md) +- [39] xApp\_Writer\_s\_Guide\_v2.pdf: [https://wiki.o-ran-sc.org/download/attachments/17269011/xApp\\_Writer\\_s\\_Guide\\_v2.pdf?version=4&modificationDate=1625642899082&api=v2](https://wiki.o-ran-sc.org/download/attachments/17269011/xApp_Writer_s_Guide_v2.pdf?version=4&modificationDate=1625642899082&api=v2) +- [40] SPIFFE-ID: +- [41] NIST Special Publication 800-207A: +- [42] Secure Software Development Fundamentals Courses: +- [43] O-RAN Core Infrastructure Initiative (CII) Badging: +- [44] O-RAN Software Community Projects: + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +**Near-RT RIC:** O-RAN Near-Real-Time RAN Intelligent Controller: A logical function that enables near-real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. + +**Non-RT RIC:** O-RAN Non-Real-Time RAN Intelligent Controller: A logical function within SMO that drives the content carried across the A1 interface. It is comprised of the Non-RT RIC Framework and the Non-RT RIC Applications. + +**O-CU-CP:** O-RAN Central Unit – Control Plane: a logical node hosting RRC and the control plane part of PDCP protocol. + +**O-CU-UP:** O-RAN Central Unit – User Plane: a logical node hosting the user plane part of PDCP protocol and SDAP protocol. + +**O-DU:** O-RAN Distributed Unit: a logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. + +**O-RU:** O-RAN Radio Unit: a logical node hosting Low-PHY layer and RF processing based on a lower layer functional split. This is similar to 3GPP's "TRP" or "RRH" but more specific in including the Low-PHY layer (FFT/iFFT, PRACH extraction). + +**O-eNB:** An eNB or ng-eNB that supports E2 interface. + +**O1:** An interface between SMO and O-RAN managed elements, for operation and management, by which FCAPS management, PNF (Physical Network Function) Software management, File management shall be achieved. + +**SMO:** A Service Management and Orchestration system. + +**A1:** An interface between Non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**E2:** An interface connecting Near-RT RIC and one or more O-CU-CPs, one or more O-CU-Ups, or one or more O-Dus. + +**Y1:** An interface between Near-RT RIC and Y1 consumers [32]. The interface enables RAN analytics information exposure from Near-RT RIC. + +**E2 Node:** A logical node terminating E2 interface. In this version of the specification, O-RAN nodes terminating E2 interface are: + +- for NR access: O-CU-CP, O-CU-UP, O-DU +- for E-UTRA access: O-eNB. + +**xApp:** An application designed to run on Near-RT RIC. It may consist of one or more microservices and at the point of on-boarding it identifies which data it consumes and which data it provides. It is independent of Near-RT RIC and may be provided by any third party. The E2 interface enables a direct association between xApp and RAN functionalities. + +**O-Cloud:** O-Cloud is a cloud computing platform comprising a collection of physical infrastructure nodes that meet O-RAN requirements to host the relevant O-RAN functions (such as Near-RT RIC, O-CU-CP, O-CU-UP, and O-DU), the supporting software components (such as Operating System, Virtual Machine Monitor, Container Runtime, etc.) and the appropriate management and orchestration functions. + +**Solution Provider:** An application developer who delivers applications to Service Providers. [22] + +**Service Provider:** A network provider who is planning to deploy applications into their network. [22] + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +## 3.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply: + +| | | +|-------------|------------------------------------------------------------| +| API | Application Programming Interface | +| AI/ML | Artificial Intelligence/Machine Learning | +| CP | Control Plane | +| DoS | Denial of Service | +| DTLS | Datagram Transport Layer Security | +| eNB | e NodeB (applies to LTE) | +| E2SM | E2 Service Model | +| FCAPS | Fault, Configuration, Accounting, Performance, Security | +| FM | Fault Management | +| gNB | g NodeB (applies to NR) | +| IPsec | Internet Protocol Security | +| JWS | JSON Web Signature | +| JWT | JSON Web Token | +| LCM | Life-Cycle Management | +| MEC | Multi-access Edge Computing | +| MIMO | Multiple Input Multiple Output | +| Near-RT RIC | Near-real-time RAN Intelligent Controller | +| NIB | Network Information Base | +| Non-RT RIC | Non-real-time RAN Intelligent Controller | +| O-CU | O-RAN Central Unit | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| PM | Performance Management | +| QoS | Quality of Service | +| QoE | Quality of Experience | +| RAIE | RAN Analytic Information Exposure | +| RAI API | RAN Analytics Information API, internal to the Near-RT RIC | +| RAN | Radio Access Network | +| RIC | RAN Intelligent Controller | +| R-NIB | Radio-Network Information Base | +| RRM | Radio Resource Management | +| SBA | Service Based Architecture | +| SDL | Share Data Layer | +| SMO | Service Management and Orchestration | + +| | | +|--------|---------------------------------------------------------------------------------------| +| TLS | Transport Layer Security | +| UE | User Equipment | +| UE-NIB | UE-Network Information Base | +| UP | User Plane | +| Y1 API | RAN Analytics Information API, for consumers outside of the Near-RT RIC | +| Y1T | Y1 API Termination, i.e. Near-RT RIC platform function implementing a Y1 API provider | + +# 4 RIC background, concepts and assumptions + +## 4.1 Introduction + +The RIC architecture consists of the Non-RT RIC, which deals with control loops of more than 1 second, and the Near-RT RIC, with control loops in the order of 10 ms to 1s [3]. The Non-RT RIC is embedded in the Service and Management Orchestration function and hosts rApps to provide policy-based guidance, machine learning model management and enrichment information to the Near-RT RIC function for the purpose of RAN optimization [4]. The Near-RT RIC is a logical function that enables near real-time control and optimization of E2 Nodes functions and resources, steered via the policies and enrichment data provided from the Non-RT RIC [3]. + +## 4.2 Near-RT RIC architecture + +The following diagram shows the building blocks of the Near-RT RIC internal architecture. For more detailed descriptions of the architecture and platform functions, see WG3 Near-RT RIC Architecture specification [3]. + +![Figure 4.2-1: Near-RT RIC Internal Architecture diagram](8a910c57c57a6a28ed284fe42f95e548_img.jpg) + +The diagram illustrates the internal architecture of the Near-RT RIC. At the top, the Service Management and Orchestration (SMO) block contains the Non-RT RIC. The Non-RT RIC connects to the Near-RT RIC via interfaces O1 and A1. The Near-RT RIC is a large container with several internal components: + + +- Termination Points:** O1 Termination, A1 Termination, and Y1 Termination are located at the top of the Near-RT RIC. Y1 Termination connects to Y1 Consumers outside the Near-RT RIC. +- Near-RT RIC APIs for xApp:** A dashed box contains xApp 1, xApp 2, and xApp N. +- API Enablement:** A vertical label on the left side of the xApp box. +- Messaging Infrastructure:** A horizontal bar below the xApp box, containing Conflict Mitigation, xApp Subscription Management, Management Function, Security, AI/ML Support, and xApp Repository Function. +- Shared Data Layer:** A horizontal bar below the Messaging Infrastructure, containing a Database. +- E2 Termination:** A block at the bottom of the Near-RT RIC, connected to E2 Nodes via interface E2. + +Figure 4.2-1: Near-RT RIC Internal Architecture diagram + +**Figure 4.2-1: Near-RT RIC Internal Architecture** + +- **Interface Termination** for E2, A1, O1, Y1 +- **xApp:** application that runs on the Near-RT RIC to provide desired RAN functionality + +- **Messaging infrastructure:** provides low-latency message delivery service b/t Near-RT RIC internal endpoints +- **Conflict mitigation:** resolves potentially overlapping or conflicting requests from multiple xApps +- **Subscription management:** manages subscriptions from xApps to E2 Nodes and enforces authorization of policies +- **Management services:** life-cycle management of xApps (onboarding, deployment, resource management, and termination) and FCAPS management of Near-RT RIC (logging, tracing, metrics collection) +- **Security:** provides the security scheme for the xApps. One of the targets of this function is to prevent malicious xApps from abusing radio network information (e.g. exporting to unauthorized external systems) and/or control capabilities over RAN functions + +**Note.** The Security function is a placeholder in Near-RT RIC architecture and has not been specified yet. The requirements and solutions proposed in this study will support the specification of this function. + +- **AI/ML support:** provides data ingestion and preparation for xApps and AI/ML training for xApps +- **xApp Repository Function:** performs selection of xApps for A1 message routing and provides policy types supported in Near-RT RIC to the A1 termination function +- **Shared Data Layer (SDL):** API for accessing shared data storage +- **Database:** UE-NIB database contains a list of Ues and associated data, and Radio-NIB database stores configurations and information relating to the connected E2 Nodes +- **API Enablement:** support for registration, discovery and consumption of Near-RT RIC APIs +- **Y1 Consumers:** communicate via Y1 interface and consume RAN analytics information service(s) from Near-RT RIC + +## 4.3 Interfaces + +**E2:** Interface between the Near-RT RIC and the E2 Nodes (O-DU, O-CU-UP, O-CU-CP, O-eNB) [5] + +**O1:** Interface between the SMO and O-RAN Managed Functions (Near-RT RIC, O-RU, O-DU, O-CU-UP, O-CU-CP, O-eNB) [6][7][8] + +**A1:** Interface between the Non-RT RIC at the SMO and the Near-RT RIC [9] + +**Y1:** communicates with Y1 consumers via Y1 interface and exposes RAN analytics information service(s) from Near-RT RIC. + +## 4.4 xApps + +As per definition in [3], an xApp is an application designed to run on Near-RT RIC. It may consist of one or more microservices and at the point of on-boarding it identifies which data it consumes and which data it + +provides. It is independent of Near-RT RIC and may be provided by any third party. The E2 interface enables a direct association between xApp and RAN functionalities. + +From security viewpoint the following requirements [3] are key aspects to take into consideration in this study, and will be developed in subsequent key issues and solutions: + +- xApps shall communicate with Near-RT RIC platform via Near-RT RIC APIs. +- xApps shall use Near-RT RIC APIs to make use of the Information Elements (Ies) **only** of the E2 Service Models (E2SM) that are associated with it. + + +Note. E2SM describes the functions in the E2 Node which may be controlled by the Near-RT RIC and corresponding procedures. +- xApp shall register the APIs it produces. + + +Note. Services for which the API producer is the xApp are FFS +- xApp shall be capable of discovering the Near-RT RIC APIs they consume +- The platform will consider the level of trust related to the xApp, e.g. 3rd party xApp, RIC-owned xApp (i.e. xApp provided by the RIC vendor) + +## 4.5 Near-RT RIC APIs + +The following diagram [3] provides a representation of the APIs involved in Near-RT RIC. + +![Figure 4.5-1: Overview of Near-RT RIC APIs. The diagram shows the Near-RT RIC platform containing xApps (xApp #1, xApp #2, ..., xApp #n) and a Shared Data Layer. APIs are categorized into Enablement APIs (API Enablement, Shared Data Layer, SDL APIs), A1 Related APIs (A1 Termination, A1 Related APIs), E2 Related APIs (E2 Termination / Conflict Mitigation / xApp Subscription Management), and Management APIs (O1 Termination / Management Service). A Framework for Transactions on APIs is shown at the bottom.](a14f0c7149401d7ad3abd09fee0b1f1f_img.jpg) + +Figure 4.5-1: Overview of Near-RT RIC APIs. The diagram shows the Near-RT RIC platform containing xApps (xApp #1, xApp #2, ..., xApp #n) and a Shared Data Layer. APIs are categorized into Enablement APIs (API Enablement, Shared Data Layer, SDL APIs), A1 Related APIs (A1 Termination, A1 Related APIs), E2 Related APIs (E2 Termination / Conflict Mitigation / xApp Subscription Management), and Management APIs (O1 Termination / Management Service). A Framework for Transactions on APIs is shown at the bottom. + +**Figure 4.5-1: Overview of Near-RT RIC APIs** + +- **A1 related APIs:** APIs allowing to access A1 related functionality. + - o **Policy Enforcement API** (transactional) + - o **Enrichment information API** (transactional) + +- **E2 related APIs:** APIs allowing to access E2 related functionality and associated xApp Subscription Management and Conflict Mitigation functionality. + - **E2 Subscription API** (transactional) + - **E2 Guidance** (transactional) + - **E2 Indication** (time critical, uni-streaming) + - **E2 Control** (time critical, bi-streaming) +- **Management APIs:** APIs allowing to access management related functionality. They are used for services such as O1 Termination, management services and logging, tracing, metrics collection. + - **ML model related APIs** (FFS) + - **FCAPS related APIs** (transactional): + - **xApp Registration API** + - **xApp Deregistration API** + - **Configuration API** + - **PM** (Performance Management) **API** + - **FM** (Fault Management) **API** +- **SDL API** (transactional + Uni-streaming): API allowing to access Shared Data Layer related functionalities (store/fetch/notify/modify/push/...) over R-NIB, UE-NIB, other data in the database. +- **Enablement APIs** (transactional): APIs between xApps and API enablement functionality. + - **Registration API.** Enabling the API producer to register the APIs it produces + - **Discovery API.** Enabling the discovery of the Near-RT RIC APIs by the xApps + - **Subscription API.** Enabling the subscription/un-subscription to API-related events and event notification. + +# --- 5 Key Issues + +## 5.1 Introduction + +This clause details the key issues identified for security aspects related to the Near-RT RIC architecture, relevant interfaces, xApps and APIs. Each key issue defines the background to the issue, defines the threats related to the issue and proposes requirements that resolve or mitigate the key issue. + +## 5.2 Key Issue #1: Malicious xApps deployed on the Near-RT RIC + +### 5.2.1 Key issue detail + +xApps on the Near-RT RIC can collect near real-time information from E2 Nodes and influence behavior of E2 Nodes thereby impacting cell performance and delivery of services to a group of Ues or a single UE. The security requirements for onboarding and hosting xApps should be defined to reduce the risk of unauthorized, untrusted, or malicious xApps to be deployed into the Near-RT RIC. + +Malicious xApps could be onboarded onto the Near-RT RIC with the intent of manipulating or negatively impacting the delivery of services to subscribers, the RAN, or the core network. Malicious xApps could also be onboarded onto the Near-RT RIC with the intent of accessing, manipulating or negatively impacting the privacy of subscribers, the RAN or the core network. + +This threat has been identified in O-RAN Threat Model [1] as Threat ID T-NEAR-RT-01. + +### 5.2.2 Security threats + +The security threats associated with the onboarding and deployment of malicious xApps include: + +- Malicious xApps attaining unauthorized access to the Near-RT RIC and E2 Nodes +- Malicious xApps abusing radio network information and control capabilities over RAN functions +- Malicious xApp impacting service for a subscriber or a dedicated area +- Malicious xApp exploiting UE identification, tracking UE location and changing UE slice priority + +### 5.2.3 Potential security requirements + +xApps shall be authenticated during onboarding using a signature that is generated by the xApp Solution Provider and validated by the Service Provider. + +xApps shall be validated during Registration to the Near-RT RIC platform using signatures from both the Service Provider and the xApp Solution Provider. + +## 5.3 Key Issue #2: Compromised xApp + +### 5.3.1 Key issue detail + +Vulnerabilities can potentially exist in any xApp. Those can be e.g.: + +- Security misconfiguration, such as enabled but unnecessary protocols +- Weak or misconfigured authentication and authorization +- A malicious xApp an untrusted source may intentionally provide +- A backdoor intentionally inserted in the xApp by a trusted source + +- An attacker submitting requests without prior authentication and authorization by executing an injection attack to manipulate configurations, access logs, perform remote code execution, etc + +If attackers can find an exploitable xApp, they can disrupt the offered network service and potentially take over another xApp or the Near-RT RIC. The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted by any accessible API, extract sensitive information, etc. + +### 5.3.2 Security Threats + +The security threats associated with compromised xApps include: + +- Security misconfiguration +- Weak authentication and authorization +- Malicious xApps from an untrusted source +- Backdoors in trusted xApps +- Vulnerabilities in trusted apps + +### 5.3.3 Potential security requirements + +**Requirement:** xApps images shall be authenticated during onboarding using a signature that is generated by the xApp Solution Provider and validated by the Service/Cloud Provider and telco operator. + +**Requirement:** xApps instances shall be validated during Registration to the Near-RT RIC platform using signatures from both the Service/Cloud Provider and the xApp Solution Provider. Signatures made from certificates reaching the end of their lifetime shall be renewed before the certificate times out (signatures provided by the xApp Solution Provider might be ignored if the signature of the Service/Cloud Provider is valid). + +**Recommendation:** xApps should be hardened by the vendor, and this hardening should be tested by the service provider, using a well-defined standard, e.g., using penetration tests + +**Requirement:** xApp APIs shall be provided with proper Authentication/Authorization schemas. + +**Recommendation:** prevent supply chain attacks, e.g., as defined in [24] + +## 5.4 Key Issue #3: Conflicting xApps + +### 5.4.1 Key issue detail + +xApps can change RAN parameters to optimize a specific network metric, which could result in conflicting actions between xApps. Conflicting xApps can unintentionally or maliciously impact O-RAN system functions such as mobility management, admission controls, radio resource control, and load balancing to degrade the performance or availability of the network. + +The functional split between the Near-RT RIC and the E2-Node depends on the available xApps and the capabilities exposed by the O-gNB. This can create possible conflicts between the decisions taken by the Near-RT RIC and the O-gNB that could lead to instability in the network, which introduces vulnerabilities that could be exploited by threat actors. [1] + +This threat has been identified in O-RAN Threat Model [1] as Threat ID T-xApp-02. + +### 5.4.2 Security threats + +The security threats associated with conflicting xApps include: + +- DoS from an xApp intentionally creating RRM decisions that conflict with gNB internal decisions +- Degradation of performance from an xApp intentionally creating RRM decisions that conflict with other xApp decisions + +### 5.4.3 Potential security requirements + +The solution should make use of the existing, but currently optional, E2 Guidance Request Procedure during xApp Registration to mitigate conflicts arising from new xApps. The purpose of the E2 Guidance procedures is to allow xApps to obtain guidance from the Conflict Mitigation function in the Near-RT RIC. The Conflict Mitigation function is intended to resolve potentially overlapping or conflicting requests from multiple xApps, but some conflict mitigation messages and procedures are FFS [3]. + +## 5.5 Key Issue #4: Isolation between xApps + +### 5.5.1 Key issue detail + +The Near-RT RIC enables near real time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface, and includes open interfaces (A1, O1) to the management and orchestration system (SMO). This will be achieved using a collection of xApps, with each xApp providing a specific functionality by consuming a specific subset of data or producing data for other xApps or Near-RT RIC platform. To provide its desired functionality, the xApps would interact with other Near-RT RIC platform components. + +In a multi-vendor environment, where 3rd party xApps and those provided by the RIC vendor are deployed together, an xApp can be used to impact the other co-located xApps/Near-RT RIC platform thus creating a noisy neighbour effect where an xApp can overconsume the underlying shared resources provided by the Near-RT RIC platform like CPU, memory, I/O bandwidth, etc. and can negatively affect the performance of other co-located xApps and potentially other CNFs sharing the same underlying platform. + +It's also possible that xApps have different levels of access to the data and resources available on Near-RT RIC. Appropriate isolation is needed for xApps that have different threat profiles. + +### 5.5.2 Security threats + +Without proper isolation, an xApp can be used to: + +- overconsume the platform resources shared by all xApps, creating a noisy neighbour effect by leaving other co-located xApps with a resource deficit. +- administer DoS attacks on other co-located xApps and impacting service offered by the xApp under attacks + +- administer DoS attacks on the Near-RT RIC platform components, impacting the availability of the Near-RT RIC +- administer unauthorised access to sensitive real-time information from RAN, persistent configuration used by the Near-RT RIC to control the RAN +- probe for vulnerabilities in the underlying system hosting the xApps application and use them to administer attacks on another xApps and the platform + +### 5.5.3 Potential security requirements + +**Requirement:** Based on xAPPs threat profile, the Near-RT RIC platform shall categorise and isolate xAPPs into different security groups and define security boundaries. Near-RT RIC platform shall cap the resources allocated to xAPPs make sure that xAPPs trying to overconsume the resources are quarantined. + +**Requirement:** Access controls shall be established and enforced for accessing critical data in Near-RT RIC + +**Requirement:** Communication between security zones shall require mutual authentication and authorization between communicating xAPPs + +## 5.6 Key Issue #5: Compromise of ML data pipelines used in Near-RT RIC + +### 5.6.1 Key issue detail + +The Near-RT RIC contains database(s) which contain historic data collected from UE and RAN information. This historic data can be used to train various ML models used in Near-RT RIC. Also, streaming data may be collected from E2 nodes by some ML based xAPPs, and used either for training ML models or deriving inferences. + +ML data pipelines can consist of several ML models, using one or more sources of data for training as well as inference derivation. xAPPs can have ML pipelines implemented within, or can be using ML pipelines from another xAPPs that provide analytics services. + +ML data pipelines can be compromised due to: + +- A potential vulnerability existing in the xApp that implements the ML pipeline +- Poisoning of ML training data due to compromised E2 node(s) +- Poisoning of ML training data due to compromised UE(s) +- Compromised database(s) which store historic data used for ML training +- Compromised interfaces of Near-RT RIC allowing a malicious intruder to alter some of the training data that may be used to train ML models used by xAPPs + +### 5.6.2 Security threats + +T\_ML\_01 from ORAN Threat Modelling [1] is applicable here. + +### 5.6.3 Potential security requirements + +The following security requirements should be considered: + +- Secure data storage, and secure data transfer mechanisms shall be implemented in Near-RT RIC. +- Authenticated and authorized access to data stores shall be implemented in Near-RT RIC. +- Near-RT RIC deployment shall have provision for regular security vulnerability patch updates for xApps. +- Integrity of xApps shall be monitored after installation as well as during runtime on a periodic or need basis. +- O-Cloud security requirements shall be adhered to, in order to ensure that the interfaces feeding data to ML data pipelines are secured. +- Detection of compromised E2 nodes, and filtering ML data pipelines to exclude inputs from such nodes. +- Detection of compromised UE, and filtering ML data pipelines to exclude inputs from such Ues. + +## 5.7 Key Issue #6: Altering the ML learning models used in Near-RT RIC + +### 5.7.1 Key issue detail + +Near-RT RIC hosts a set of xApps, some of which may contain ML based solutions performing inference and/or training processes. + +- ML enabled xApps can hold any required ML models and would be deployed as an integrated function. + - In such cases, if ML models use online training, or transfer learning, or reinforcement learning, or other such mechanisms, it is likely that during runtime, the binary footprint of the models can change for good reasons. However, this makes it a challenge to distinguish between maliciously modified ML models and genuine model changes. +- xApps can also use ML models stored in databases or separate filesystems/storage + - xApps can perform online training of ML models by updating the models in DB, while ensuring that the binary footprint of xApp remains un-changed + +For xApps having embedded ML models, a compromise of ML models is likely due to following reasons: + +- A potential vulnerability existing in xApp +- Security Weakness in APIs exposed by xApps + - For example, APIs allowing modifications of ML models using transfer learning can allow changes of models by a malicious source, if authentication and authorization for such interfaces are not strong + +For xApps using ML models stored in DB/separate storage, a compromise of ML models is likely due to following reasons: + +- A potential vulnerability existing in xApp leading to compromised ML model updated in the DB +- A potential vulnerability existing in DB security + - Missing or weak authentication and authorization for DB + +Transfer Learning can be implemented in a manner that Non-RT RIC can provide updated ML models to Near-RT RIC via A1 interface. If this interface is compromised, or, if an un-authenticated or un-authorized source is allowed to update ML models in Near-RT RIC, it can lead to unexpected behaviour of ML models. + +### 5.7.2 Security threats + +T\_ML\_02 from ORAN Threat Modelling [1] is applicable here. + +An attacker can illegally access a machine learning model and alter its parameters and thereby influence how it produces results. This can lead to wrong prediction and might result in catastrophic decisions if the results of the predictions were being used to make key business decisions. + +Also, an attacker can extract sensitive or confidential data that, through training, are built right into the ML model. + +### 5.7.3 Potential security requirements + +Following security requirements should be considered: + +- Integrity of xApps shall be monitored after installation as well as during runtime on a periodic or need basis. +- Secure data storage, and secure data transfer mechanisms shall be implemented in Near-RT RIC. +- Authenticated and authorized access to data stores shall be implemented in Near-RT RIC. Security measures shall be ensured to allow only authenticated and authorized applications providing ML model updates over the A1 interface. + +## 5.8 Key Issue #7: Data Protection and Privacy in Near-RT RIC Database + +### 5.8.1 Key issue detail + +The Near-RT RIC contains database(s) which contain sensitive UE and RAN information, including history of the network state, configurations related to E2 Nodes, cells, bearers, flows, UE identities, and the mappings between them. Overlaid on top of these databases is the shared data layer (SDL) which enables xApp access. There is currently no model for authentication or authorization for the database(s). The Near-RT RIC requires security mechanisms in place to ensure xApps have authenticated access to the database(s) and may access only parts of the database(s) in which they have permission to access. Adverse effects may result if no security mechanisms are in place, such as manipulation of database information. + +### 5.8.2 Security threats + +xApps that have gained unauthorized access to Near-RT RIC database(s) have the ability to: + +- Perform unauthorized database operations and manipulate database information to impact network service and performance +- Export sensitive data from the Near-RT RIC database(s) (data or user privacy threat) + +- Monitor the database for specific information and take an adverse action + +### 5.8.3 Potential security requirements + +Near-RT RIC shall authenticate xApp access to the Near-RT RIC database(s) during SDL registration. + +Near-RT RIC shall provide authorized access to Near-RT RIC database(s). + +## 5.9 Key Issue #8: Onboarding untrusted xApps + +### 5.9.1 Key issue detail + +As per definition in [3], an xApp is an application designed to run on Near-RT RIC. It may consist of one or more microservices. It is independent of Near-RT RIC and may be provided by any third party. As part of offering its service to Near RT-RIC, some of the xApp's functionalities include + +- communicating with Near-RT RIC platform via Near-RT RIC API, +- providing the APIs it produces to other xApps and Near-RT RIC, +- collecting near real-time information from E2 Nodes and influence behaviour of E2 Nodes and +- accessing Near-RT RIC Databases (via SDL) which gives access to sensitive information related to UE and RAN + +Onboarding an untrusted third party xApp onto Near-RT RIC can create serious security issues which can compromise the Near-RT RIC functionality, impact the availability of other xApps and have cascading impact on overall performance of ORAN. + +### 5.9.2 Security threats + +Onboarding an untrusted third party xApp onto Near-RT RIC can cause similar or same security threats as a Malicious or Badly configured xApp. Some well-known and easily administrated attacks with untrusted xApps are: + +- If the xApp is not from a trusted source or is not maintained by a trusted source, it could contain security vulnerabilities or back doors which could be exploited by the attackers and impact Near-RT RIC functions +- The untrusted/unverified xApp could provide APIs with weak security (weak or no authentication and authorization) and such xApps could be easy target for attackers to break in and propagate lateral movement of attack in the system (towards other xApps). +- The untrusted/unverified xApp could expose more services than required and such xApps could expose a large attack surface to the attackers to break in and gain access, manipulate configurations, access logs, insert back doors +- The untrusted/unverified xApp can be used to sniff sensitive UE information which can be used by attackers or the untrusted/unverified xApp itself for rogue purposes + +### 5.9.3 Potential security requirements + +**Requirement:** The xApp shall be compliant to industry standards for API security (eg : OWASP Top 10) + +**Requirement:** The xApp shall be free of any known software vulnerabilities. + +**Requirement:** The xApp shall be authenticated before the app is onboarded to the cloud platform and registered onto the Near-RT RIC platform + +**Requirement:** The xApp shall support appropriate authorization schemes to make sure that a user accessing its service shall not be able to execute any actions that the user is not authorized for. + +**Requirement:** The xApp shall harden its service offering by making sure that only required services should be exposed to its users. + +## 5.10 Key Issue #9: xApp exploitation via malicious A1 policies + +### 5.10.1 Key issue detail + +The Non-RT RIC defines policies that are provided to the Near-RT RIC over the A1 interface. The purpose of the A1 policies is to guide and optimize the RAN, and the policies inform behavior of xApps in the Near-RT RIC. [9] + +Unauthorized access to the Non-RT RIC enables the creation of ‘false policies’ that can be issued to the Near-RT RIC for enforcement. Existing Near-RT RIC policies could also be modified to achieve a false policy. False policies passed to the Near-RT RIC would be persistent until they were modified or deleted by the Non-RT RIC or the Near-RT RIC power cycles. + +### 5.10.2 Security threats + +False policies can be created to have numerous impacts to the normal performance of the RAN. A single false A1 policy can target a specific UE, groups of UEs, or an entire cell. A false policy could influence the Near-RT RIC to configure the O-DU and O-RU functions to support Denial of Service (DoS) attacks by simply using feedback data to degrade RAN performance. + +False policies could also be used for the purpose of locating a subscriber or group of subscribers. In this case, the false policy would cause the Near-RT RIC to isolate a subscriber in the O-CU. The Near-RT RIC could also use MIMO beamforming in the O-DU and O-RU to isolate a user onto a single beam. The data feedback from the RAN can include UE location or trajectory information from GPS data. The subscriber location would be attained from access to the Non-RT RIC in the SMO function. + +The Near-RT RIC is capable of steering traffic to achieve optimal QoS or QoE performance. A false policy could notionally cause the Near-RT RIC to steer user data to isolate the data in order to facilitate a cyber-attack. + +### 5.10.3 Potential security requirements + +Security protections are defined for the A1 interface and security work is in process for A1 related APIs and the Non-RT RIC. For example, A1 peering should be established with only trusted sources using TLS 1.2, or higher, and PKI X.509 certificates, as specified in [19]. TLS also provides confidentiality and integrity + +protection. Additional Near-RT RIC authentication of the A1 policy may be a consideration later, after the above security protections are defined and evaluated. + +A perimeter security approach may enable an Internal threat actor to conduct a MitM attack on the A1 interface. Security for the Near-RT should take a zero-trust approach in which security controls are implemented at the Near-RT RIC without assumption of a secure perimeter. The Near-RT RIC could implement security controls consistent with a zero-trust architecture in which there is no assumption of perimeter defences being provided by other O-RAN functions. For example, the Near-RT RIC could provide checking and validation of policies received from the Non-RT RIC on the A1 interface. + +## 5.11 Key Issue #10: Near-RT RIC APIs authentication + +### 5.11.1 Key issue detail + +Like any software, APIs can be compromised, and data can be intercepted. APIs can be manipulated causing service disruptions and can be subject as well to DoS attacks. Authentication, an essential part of secure communication, ensures that an attribute claimed by a given entity (e.g., its identity) is actually correct. In the context of secure communication between xApps and Near-RT RIC platform, the platform shall authenticate all xApps instances and only provide them with the information and services for which they are authorized through the use of the Near-RT RIC APIs, as a key objective to guarantee the validity of the transferred messages. xApps can also act as service producers, exposing APIs to be consumed by other xApps for example. In that case, the xApps 'producers' shall authenticate the instances interested in consuming those xApp services. Authentication is also a prerequisite for conducting authorization which itself is another key issue for API Security. + +Note that using the xApp registration procedure Near-RT platform performs authentication and validation of the xApp, addressed in solution #1, however xApps, as consumers of the services exposed by Near-RT RIC APIs, are not authenticated as per current O-RAN specifications at the time of requesting those services. + +### 5.11.2 Security threats + +Not mutually authenticating xApps and Near-RT RIC platform APIs could potentially allow attackers to perform the following type of attacks [17]: + +- Operating malicious xApp claiming to be genuine in order to request certain services (theft of services) or information (data leakage) +- Man in the middle attacks between a genuine xApp and a Near-RT RIC platform API +- Querying network or UE information from a compromised xApp to Near-RT RIC platform (e.g. database via SDL API), thereby leaking potentially sensitive data about network and/or UE (potential privacy issues) +- Subscribing a malicious xApp to services provided by the Near-RT RIC platform, such as API-related events notifications, discovery of APIs, E2SM, etc. + +The use of weak credentials in the process of API authentication can compromise the overall system. The user/password combination isn't considered safe, not only for password related attacks (e.g., brute-force), but also it would represent a high risk to allow xApps, especially 3rd party xApps, to store the user/password combo. This approach would extend the attack surface into xApps side. + +As a reference, OWASP API Security Top 10 report [10] indicates that authentication mechanisms are often implemented incorrectly, allowing attackers to compromise authentication tokens or to exploit implementation flaws to assume other use's identities temporarily or permanently. Compromising system's ability to identify the client/user, compromises API security overall. + +### 5.11.3 Potential security requirements + +The communication between xApps and Near-RT RIC platform APIs shall be authenticated at least at the transport layer (for e.g., with mutual TLS). + +At application layer complementary end to end authentication mechanisms based on JSON Web Tokens (JWTs) may be considered as well. + +## 5.12 Key Issue #11: Near-RT RIC APIs authorization + +### 5.12.1 Key issue detail + +Authorization is the function of specifying and enforcing access rights or privileges to certain resources or services. In the actual context of Near-RT RIC, the platform as API producer shall be responsible to specify those rights/privileges for the platform services as resources to the xApps as consumers. In general, an xApp should only have the required set of permissions to perform the actions for which they are authorized, and no more. + +Note. The investigation of services for which the API producer is the xApp is FFS [3]. + +Authorization mechanisms are to be enforced by the Near-RT RIC platform among other in the following key API procedures [3]: + +- **Discovery of Near-RT RIC APIs:** The Near-RT RIC platform shall provide means to restrict xApps from discovery of some published APIs based on configuration policies. +- **E2 Subscription API procedure:** The subscription management shall be based on operator's policies. An xApp may be restricted to interface with only a subset of E2 Nodes by such policies. This procedure establishes a set of preconditions that assume authorization processes: + - xApp has been authorized to issue E2 Subscription API requests + - xApp has been authorized to request guidance from Conflict mitigation + - xApp Subscription Management has been configured to permit E2 Subscription API requests only from specific list of xApps. +- **E2 Control API procedure:** Only authorized xApps may initiate RIC control request messages issued by the Near-RT RIC over the E2 interface to the E2 Nodes, for a specific scope (e.g, E2 Node list, RAN function, etc.). +- **E2 Guidance API procedure:** The purpose of this procedure only authorized xApp to obtain guidance from the conflict mitigation platform function prior to initiating an action. +- **SDL API procedures:** The precondition to consume the services exposed by SDL API (e.g, client registration, fetch data, notification, store, etc.) is that xApps have been successfully registered and authorized. + +### 5.12.2 Security threats + +If the API consumers are not authorized by the API producers, attackers (e.g, malicious xApps) would potentially be able to perform the following types of attacks: + +- Abuse and/or theft of services or information (data leakage), requesting and successfully obtaining them from the platform, e.g, in order to extract potentially sensitive information from the network and/or uEs +- Negatively impacting the network performance due to malicious policies over E2 Nodes +- Flooding the platform with resource demanding operations that may lead to a Denial of Service attack + +As a reference, OWASP API Security Top 10 report [10] indicates that ‘Broken Object Level Authorization’ has been the most common and impactful attack on APIs. Even if the application implements a proper infrastructure for authorization checks, developers might forget to use these checks before accessing a sensitive object. Unauthorized access can result in data disclosure to unauthorized parties, data loss, or data manipulation. + +### 5.12.3 Potential security requirements + +Near-RT RIC architecture shall provide an authorization framework for the consumption of the services exposed in the platform APIs by the xApps, that takes operator policies into consideration. The framework should be used by the specified API procedures in [3]. + +The authorization framework may need to consider the level of trust related to the xApp (e.g. 3rd party xApp, RIC-owned xApp, etc.) + +## 5.13 Key Issue #12: xAppID abuse + +### 5.13.1 Key issue detail + +As part of the xApp registration procedure into the Near-RT RIC platform, the platform assigns an identity (ID) to the xApp, so called xApp ID. This xApp ID is assumed to be used in xApps API request messages to the Near-RT RIC platform to enable the Near-RT RIC platform to identify the xApp (API service consumer). For the platform to trust the xAppID in the xApps request messages it is necessary to bind this xAppID to some trust anchor. Also, the xAppID needs to be uniquely identifying a single xApp instance. + +### 5.13.2 Security threats + +Not uniquely identifying xApps using a trusted xAppID potentially entails certain threats and potential attacks: + +- A non-unique xAppID might cause misidentification of an xApp, possibly allowing a potentially malicious xApp to request certain services (theft of services), information (data leakage), or alter existing information +- A malicious xApp might use the xAppID assigned to a legitimate xApp to request services or information from Near-RT RIC platform +- A non-unique xApp ID could make it impossible to accurately assign actions to the correct xApp + +- A non-unique xApp ID could make it difficult to recognize that a malicious xApp is in the environment + +### 5.13.3 Potential security requirements + +The Near-RT RIC shall provide a procedure to embed the xAppID into a trust anchor (e.g., X.509 certificate) assigned to the xApp used for authentication (mTLS) and for authorization (OAuth – client authentication). + +The Near-RT RIC shall create each xAppID using procedures that avoid duplicates, such as UUID as described in IETF RFC 4122. + +## 5.14 Key Issue #13: Malicious Y1 Consumer + +### 5.14.1 Key issue detail + +Near-RT RIC provides RAN analytics information services via Y1 service interface. These services can be consumed by Y1 consumers by subscribing to or requesting the RAN analytics information via the Y1 service interface. Y1 consumers may be Application Functions (AFs) which are within an O-RAN trusted domain. AFs outside the O-RAN trusted domain may use Y1 services, too. + +Malicious Y1 consumer functions may use their access through the Y1 interface with the intent of accessing, manipulating or negatively impacting the privacy of subscribers, the RAN or the core network. + +### 5.14.2 Security threats + +An attacker may use a malicious Y1 consumer function to + +- attain unauthorized access to the Near-RT RIC +- abuse radio network information +- exploit UE identification or otherwise impact the privacy of subscribers + +In addition, an attacker may perform a man in the middle attack between a genuine Y1 consumer and the Near-RT RIC platform. + +A malicious attacker may also use access to the Y1 interface to mount volumetric and non-volumetric DoS attacks on the Near-RT RIC in order to impact its overall performance. + +### 5.14.3 Potential security requirements + +All Y1 consumers shall be properly authenticated and authorized before access to the Y1 functions get enabled for them at least at the transport layer (for e.g., with mutual TLS and OAuth). All communication through the interface shall be confidentiality and integrity protected. Y1 consumers may be within a PLMN trusted domain. Y1 consumers located outside of the PLMN trusted domain should only be able to use the Y1 services via an exposure function acting as a Y1 Consumer, e.g. as specified in 3GPP TS 23.501, Clause 5.20 [33]. + +Additional security measures should be defined such as + +- the Near-RT RIC should provide checking and validation of the data received +- the Near-RT RIC should implement ingress message rate limiting on its Y1 interface + +## 5.15 Key Issue #14: Malicious E2 Node + +### 5.15.1 Key issue detail + +E2 Nodes communicate with the Near -RT RIC through the E2 interface. The Near -RT RIC uses the E2 interface to collect near real-time information and provide value added services. The Near-RT RIC Architecture specification [2] clause 8.1 provides further details on the E2 interface. + +A malicious actor may use unauthorized access to E2 Nodes or the E2 interface to mount malicious attacks against the Near-RT RIC. A malicious actor may also abuse compromised E2 Nodes properly authenticating to the Near-RT RIC. + +### 5.15.2 Security threats + +Altered and misleading data sent from a compromised E2 Node to the Near-RT RIC may cause the Near-RT RIC to draw erroneous conclusions on the RANs status which may impact the normal performance of the RAN. An attacker may also obtain information on the status of the RAN and details on the UEs. + +A malicious attacker may also use access to the E2 interface to mount volumetric and non-volumetric DoS attacks on the Near-RT RIC in order to impact its overall performance. + +### 5.15.3 Potential security requirements + +Security protections are defined for the E2 interface as explained in clause 6.9 of the present document. + +Additional security measures should be defined such as + +- the Near-RT RIC should provide checking and validation of the data received +- the Near-RT RIC should implement ingress message rate limiting on its E2 interface termination + +# 6 Mitigations and Solutions + +## 6.1 Introduction + +This section will contain any potential Mitigations or Solutions that may be used to address or reduce the risk associated with Key Issues identified in section 5. + +## 6.2 Solution #1: Secure onboarding and deployment of xApps in Near-RT RIC + +### 6.2.1 Introduction + +xApps are applications that are onboarded to the SMO, deployed on the Near-RT RIC, and then registered in the Near-RT RIC. At each of these steps in the xApp life cycle, security measures can be applied to ensure that the xApp comes from a valid solution provider and is integrity protected. + +### 6.2.2 Solution details + +Onboarding to the SMO is the first step of the xApp life cycle. This solution details the flow from the xApp solution provider to the SMO in Figure 6.2-1. + +![Figure 6.2-1: Onboarding xApp to SMO. The diagram shows three main components: xApp Solution Provider (blue box), Service Provider (green box), and SMO (yellow box). Inside the xApp Solution Provider is a 'Solution Provider' box. Inside the Service Provider are two 'SP' boxes. Inside the SMO are two 'SMO' boxes. The process flow is: 1. Signed xApp (arrow from Solution Provider to top SP), 2. xApp validation (loop from top SP to bottom SP), 3. Re-signed xApp (arrow from bottom SP to bottom SMO).](ef605bb5673c8838aa537ba1342af1d6_img.jpg) + +``` + +graph LR + subgraph xApp_Solution_Provider [xApp Solution Provider] + SP1[Solution Provider] + end + subgraph Service_Provider [Service Provider] + SP2[SP] + SP3[SP] + end + subgraph SMO [SMO] + SMO1[SMO] + SMO2[SMO] + end + SP1 -.->|1. Signed xApp| SP2 + SP2 -.->|2. xApp validation| SP3 + SP3 -.->|3. Re-signed xApp| SMO2 + +``` + +Figure 6.2-1: Onboarding xApp to SMO. The diagram shows three main components: xApp Solution Provider (blue box), Service Provider (green box), and SMO (yellow box). Inside the xApp Solution Provider is a 'Solution Provider' box. Inside the Service Provider are two 'SP' boxes. Inside the SMO are two 'SMO' boxes. The process flow is: 1. Signed xApp (arrow from Solution Provider to top SP), 2. xApp validation (loop from top SP to bottom SP), 3. Re-signed xApp (arrow from bottom SP to bottom SMO). + +**Figure 6.2-1: Onboarding xApp to SMO** + +1. Solution provider digitally signs the xApp and sends to the Service Provider. +2. The Service Provider validates the digital signature for code integrity, performs a schema check and any operational testing, and then adds their signature to the package. +3. The xApp is published into the catalogue for visibility by the SMO. + +The next step of the xApp life cycle is deployment on the Near-RT RIC, which starts with a request to the SMO from the NF Install Project Manager to deploy new xApps on the RIC, per [23]. The SMO maps the RIC variables and instructs the O-Cloud DMS to create the xAPP Deployment and allocate the resources necessary on the Near-RT RIC O-Cloud. The DMS notifies the SMO that the xAPP Deployment has been created and the DMS assigns a Deployment ID which the SMO uses to update its xApp inventory. At the end of the deployment process, the xApp starts the registration process with the Near-RT RIC by sending a registration request to Near-RT RIC Management Services function, per [3]. + +This solution proposes a security validation request sent from the Management Services to the Security Function in the Near-RT RIC, as shown in Figure 6.2-2. + +![Figure 6.2-2: Authentication during Deployment Process. The diagram shows a sequence of three steps within a 'Near-RT RIC' container. Step 1: A dashed arrow points from 'Management Services' to 'Security Function'. Step 2: A callout box lists 'xApp security processing' steps: a. Validate Service Provider signature, b. Validate Solution Provider signature, c. Verify certificates are not revoked. Step 3: A dashed arrow points from 'Security Function' back to 'Management Services'.](7aef642d0e825a1a9c1f1442f9dd80dc_img.jpg) + +``` + +sequenceDiagram + participant MS as Management Services + participant SF as Security Function + Note over MS, SF: 1. Security validation request for xApp + MS-->>SF: + Note over SF: 2. xApp security processing: + a. Validate Service Provider signature + b. Validate Solution Provider signature + c. Verify certificates are not revoked. + SF-->>MS: 3. Security validation response + +``` + +Figure 6.2-2: Authentication during Deployment Process. The diagram shows a sequence of three steps within a 'Near-RT RIC' container. Step 1: A dashed arrow points from 'Management Services' to 'Security Function'. Step 2: A callout box lists 'xApp security processing' steps: a. Validate Service Provider signature, b. Validate Solution Provider signature, c. Verify certificates are not revoked. Step 3: A dashed arrow points from 'Security Function' back to 'Management Services'. + +**Figure 6.2-2-- Authentication during Deployment Process** + +Once the xApp is deployed and has sent a registration request to Management Services: + +1. In the Near-RT RIC, a xApp validation request is sent from Management Services to the Security Function. +2. The Security Function performs the following checks: + - a. Validate the signature of the Service Provider. Confirm the signing Service Provider is the trusted Service Provider. This proves that the valid Service Provider approved the xApp, and that the xApp has not been modified since it was approved for use by the Service Provider. + - i. Note – Consideration on different security validation processes for 3rd party xApps, as compared to xApps from the Near-RT RIC platform provider, is FFS after the impacts of all key issues and solutions have been studied. + - b. Validate signature of the xApp Solution Provider. Confirm that the signing xApp Solution Provider is a member of a trusted list of providers. This proves that the xApp came from a trusted provider and has not been modified since the Solution Provider released it. + - c. Verify that neither the Service Provider nor Solution Provider certificates are revoked. This ensures that nothing has changed to imply either signature can no longer be trusted. +3. A security validation response is sent back to Management Services, who can then continue with the xApp registration process if the checks are successful. + +In the context of WG3 Near-RT RIC Architecture specification [3], this solution would be added to Figure 9.3.1-1 to fill in details of the authentication and validity checks during registration processing. + +![Sequence diagram showing the Extended xApp Registration procedure. The diagram involves SMO, O-Cloud (DMS), xApp, and the Near-RT RIC Platform (O1 Termination, Management Services, Security Function). The process starts with an xApp sending a registration request to Management Services. Management Services then sends a security validation request to the Security Function. The Security Function processes the request (validating signatures and certificates) and returns a response. Management Services then continues registration processing (assigning ID, creating MOI) and sends a registration response back to the xApp. Finally, an optional step (if SMO has subscribed) shows Management Services notifying MOI creation to O1 Termination, which then notifies the SMO.](5b23be1d8dbd70670a8f63f10723f1f5_img.jpg) + +``` + +sequenceDiagram + participant SMO + participant OCloud as O-Cloud + participant DMS + participant xApp + participant O1Termination as O1 Termination + participant ManagementServices as Management Services + participant SecurityFunction as Security Function + + xApp->>ManagementServices: 1. <> registration request + ManagementServices->>SecurityFunction: 1a. Security validation request for xApp + Note over SecurityFunction: 1b. xApp security processing: +i. Validate Service Provider signature +ii. Validate Solution Provider signature +iii. Verify certificates are not revoked. + SecurityFunction-->>ManagementServices: 1c. Security validation response + Note over ManagementServices: 2. continue registration processing if validation passed +assign xApp ID, create xApp MOI + ManagementServices-->>xApp: 3. <> registration response + Note over ManagementServices: opt [If SMO has subscribed] + ManagementServices->>O1Termination: 4. <> Notify MOI Creation + O1Termination->>SMO: + +``` + +Sequence diagram showing the Extended xApp Registration procedure. The diagram involves SMO, O-Cloud (DMS), xApp, and the Near-RT RIC Platform (O1 Termination, Management Services, Security Function). The process starts with an xApp sending a registration request to Management Services. Management Services then sends a security validation request to the Security Function. The Security Function processes the request (validating signatures and certificates) and returns a response. Management Services then continues registration processing (assigning ID, creating MOI) and sends a registration response back to the xApp. Finally, an optional step (if SMO has subscribed) shows Management Services notifying MOI creation to O1 Termination, which then notifies the SMO. + +Figure 6.2-3 – Extended xApp Registration procedure from [3] + +### 6.2.3 Evaluation + +By requiring a secure onboarding process with authentication for all xApps, this solution addresses key issues #1, #2, #8. + +## 6.3 Solution #2: Security management of risks in open-source components of Near-RT RIC architecture + +### 6.3.1 Introduction + +O-RAN Near-RT RIC and xApps software components will hugely depend on open-source software and open-source libraries, because of agility, flexibility, community support, cost-effectiveness and many other benefits open-source community provides to meet modern software development. However, on the flip side, there are a number of risks associated with open-source software which needs to be managed. + +Key risks with Near-RT RIC and xApps open-source components: + +- Open-source software provides opportunity for attackers to exploit any known vulnerabilities. A bad actor can use publicly available information to target Near-RT RIC open-source components that have not implemented a patch for known vulnerabilities. +- Non-adaptation of secure software development practices results in unintentional insertion of vulnerable code, propagation of vulnerable code and libraries. +- Intentional backdoors can be inserted by malicious developers. +- Attackers can review the code to identify vulnerabilities. +- Non-compliance of Near-RT RIC open-source license could lead to legal action, affecting business operations and incurring financial damage to consumers. It's critical for consumers to establish processes to manage open-source software license compliance. + +### 6.3.2 Solution details + +Recommended Security best practices to manage open-source software risks listed in section 6.3.1 + +#### Maintain open-source Near-RT RIC components and xApps Inventory + +- Recommended to have Software Composition Analysis tooling to automatically scan and identify all open-source components, version(s) in use, all package dependencies, libraries, and create an accurate bill of materials (BOM), checks for policy and license compliance, security risks, protect against threats to intellectual property (IP) and version updates. + +#### Track and analyse open-source Near-RT RIC components and xApps vulnerabilities + +- Track known vulnerabilities against the inventory of open-source software and libraries. +- Run automated static application security testing to identify known vulnerabilities in open-source software components. +- Create SBOM to facilitate identification of a potential vulnerability in the software product when a CVD is released for an open-source binary, library, or package. +- Perform frequent scanning for known vulnerability or misconfiguration on open-source container image during build phase, within the registry, before deployment and during run time. Recommended to use automated tools integrated into the CI/CD pipeline. +- Perform dynamic application security testing (DAST) which can be tuned and trained to detect run-time vulnerabilities. +- Continuously monitor open-source workload during runtime for any security risks and vulnerabilities. +- Conduct Penetration testing to identify and resolve critical security defects. + +#### Remediate open-source vulnerabilities + +Software vulnerabilities fall into three categories: publicly known with a patch available for the software; publicly known without a patch (n-day); and not publicly known (0-day). Although measures should be taken to mitigate the risk of n-day and 0-day vulnerabilities, patching publicly known vulnerabilities as quickly as possible significantly reduces the risk of exploitation. + +- Patch critical vulnerabilities in the operational environment within [policy defined, suggested: < 15] days and other vulnerabilities within [policy-defined, suggested: <60] days. +- Refer to [30] +- Refer to [28] + +#### Continuously monitor for new open-source risks + +- Perform frequent scanning for known vulnerabilities during run time. +- Enable security audit logs for monitoring security events. +- Dynamic application security testing (DAST) which can be tuned and trained to detect run-time vulnerabilities. + +#### Secure Software development practice + +#### Security Best practices based on openssf secure software development practices + +- The project MUST have at least one primary developer who knows how to design secure software. + +- At least one of the project's primary developers MUST know of common kinds of errors that lead to vulnerabilities in this kind of software, as well as at least one method to counter or mitigate each of them. +- Use basic good cryptographic practices: + - The software produced by the project MUST use, by default, only cryptographic protocols and algorithms that are publicly published and reviewed by experts (if cryptographic protocols and algorithms are used). + - If the software produced by the project is an application or library, and its primary purpose is not to implement cryptography, then it SHOULD only call on software specifically designed to implement cryptographic functions; it SHOULD NOT re-implement its own. + - All functionality in the software produced by the project that depends on cryptography MUST be implementable using FLOSS. + - The default security mechanisms within the software produced by the project MUST NOT depend on broken cryptographic algorithms (e.g., MD4, MD5, single DES, RC4, Dual\_EC\_DRBG), or use cipher modes that are inappropriate to the context, unless they are necessary to implement an interoperable protocol (where the protocol implemented is the most recent version of that standard broadly supported by the network ecosystem, that ecosystem requires the use of such an algorithm or mode, and that ecosystem does not offer any more secure alternative). The documentation MUST describe any relevant security risks and any known mitigations if these broken algorithms or modes are necessary for an interoperable protocol. + - The default security mechanisms within the software produced by the project SHOULD NOT depend on cryptographic algorithms or modes with known serious weaknesses (e.g., the SHA-1 cryptographic hash algorithm or the CBC mode in SSH). + - The security mechanisms within the software produced by the project SHOULD implement perfect forward secrecy for key agreement protocols so a session key derived from a set of long-term keys cannot be compromised if one of the long-term keys is compromised in the future. + - If the software produced by the project causes the storing of passwords for authentication of external users, the passwords MUST be stored as iterated hashes with a per-user salt by using a key stretching (iterated) algorithm (e.g., Argon2id, Bcrypt, Scrypt, or PBKDF2). + - The security mechanisms within the software produced by the project MUST generate all cryptographic keys and nonces using a cryptographically secure random number generator and MUST NOT do so using generators that are cryptographically insecure. +- Secured delivery against man-in-the-middle (MITM) attacks + - The project MUST use a delivery mechanism that counters MITM attacks. Using https or ssh+scp is acceptable. + - A cryptographic hash (e.g., a sha1sum) MUST NOT be retrieved over http and used without checking for a cryptographic signature. +- Publicly known vulnerabilities fixed + - There MUST be no unpatched vulnerabilities of medium or higher severity that have been publicly known for more than 60 days. + - Projects SHOULD fix all critical vulnerabilities rapidly after they are reported. +- Static code analysis + - At least one static code analysis tool (beyond compiler warnings and ""saf"" language modes) MUST be applied to any proposed major production release of the software before its release, if there is at least one FLOSS tool that implements this criterion in the selected language. + - It is SUGGESTED that at least one of the static analysis tools used for the static\_analysis criterion include rules or approaches to look for common vulnerabilities in the analyzed language or environment. + - All medium and higher severity exploitable vulnerabilities discovered with static code analysis MUST be fixed in a timely way after they are confirmed. + - It is SUGGESTED that static source code analysis occur on every commit or at least daily. +- Dynamic code analysis + +- It is SUGGESTED that at least one dynamic analysis tool be applied to any proposed major production release of the software before its release. +- All medium and higher severity exploitable vulnerabilities discovered with dynamic code analysis MUST be fixed in a timely way after they are confirmed. + +Refer to open-source software best practices: [27], [42], [43] and [44]. + +### 6.3.3 Evaluation + +Recommended open-source best practices mitigates Near-RT RIC components and xApps open-source Risks. This solution addresses key issues #1, #2, #5, #6, #8. + +## 6.4 Solution #3: Authentication schema for APIs + +### 6.4.1 Introduction + +REST APIs and gRPC APIs are being considered as valid network solutions for Near-RT RIC API. REST APIs use HTTP and support Transport Layer Security (TLS). REST APIs utilizes JavaScript Object Notation (JSON) as encoding protocol. gRPC APIs use HTTP/2 and support as well TLS. In contrast with REST APIs, gRPC used Protobuf as encoding protocol. + +Time critical E2 related APIs are currently specified to run over SCTP/Protobuf network protocol stack. The security network layer specified for E2 interface is IPsec (SEC-CTL-E2 [2]). DTLS is proposed as optional mechanism. + +The solution proposes a basic network authentication schema for transactional APIs (REST and gRPC) based on mutual TLS (mTLS) authentication via X.509 certificates. The use of mTLS serves a dual purpose: + +- Mutual authentication +- Confidentiality protection for the authorization framework (solution #4) + +mTLS is fully aligned with Zero Trust principles of O-RAN security architecture. + +Additionally, the network authentication schema can be complemented by a client authentication schema at application layer, with the use of secure tokens (e.g. JWT, secured with digital signatures based on JWS). Authentication is a prerequisite of the authorization framework, applicable to those APIs. + +For time critical E2 related APIs, secured by IPsec, the solution proposes IKEv2 certificate-based authentication implementation according to O-RAN Security Protocols specification [19], which is aligned with 3GPP TS 33.310 specification [20] in terms of certificates and IKEv2 profiles. + +### 6.4.2 Solution details + +#### 6.4.2.1 mTLS authentication + +In mTLS both the client (e.g, xApp as API consumer) and the server (e.g, platform as API producer) require a certificate, and both sides authenticate each other using their public/private key pair. The authentication process includes the following steps: + +- the client connects to server and requests access +- the server presents a server certificate +- the client verifies the server certificate +- the client presents a client certificate +- the server verifies the client certificate +- the server grants access +- client and server can exchange information over encrypted TLS connection + +#### 6.4.2.2 Application layer client authentication + +The purpose of the solution is to perform an additional consumer authentication at application layer by the platform, which acts as authorization server and producer. The process is as follows: + +- The API consumer (e.g, xApp) shall attach a signed token in the service request towards the receiving end point, i.e, authorization server, producer. +- The signed token includes the consumer instance ID (e.g, xApp ID), that can be checked against the certificate by the producer +- The signed token includes a timestamp as basis for restriction of its lifetime. It could be even one per service request, this is up to the configuration. + +#### 6.4.2.3 IPsec authentication + +Please refer to O-RAN Security Protocols Specification [19], chapter 2.5 for supported IPsec capabilities in O-RAN. + +In summary, the following options for IPSec authentication have been specified in [19]: + +- Data origin authentication, always enabled +- ESP authentication transforms +- IKE endpoint Identification +- X.509v3 digital certificates provided by a Certificate Authority solution shall be supported +- Pre-shared Keys may be supported +- Key exchange shall be supported via IKEv2, profile as described in [21]. + +### 6.4.3 Evaluation + +The proposed authentication schema addresses the key issues #1, #2, #4, #5, #6, #7, #8, #9, #10, #11 + +Note. The authentication mechanisms described in the solution may be applicable to other O-RAN parts of the architecture. + +## 6.5 Solution #4: Authorization framework for APIs + +### 6.5.1 Introduction + +The proposed authorization framework is based on OAuth 2.0 as specified in RFC 6749 [11]. The OAuth 2.0 authorization framework enables a third-party application (e.g, xApp) to obtain limited access to a service (HTTP), either on behalf of a resource owner by orchestrating an approval interaction between the resource owner and the HTTP service, or by allowing the third-party application to obtain access on its own behalf. + +OAuth 2.0 is the framework adopted in 3GPP 5G Service Based Architecture (SBA) [13], where the NRF (Network Resource Function) acts as authorization server. + +MEC specifications [15] mandate the use of OAuth 2.0 for authorization of access to RESTful MEC service APIs, and ETSI NFV [14] also specifies the same framework for ETSI NFV-MANO APIs. + +The proposed solution implementation in Near-RT RIC architecture of O-RAN is based on the options selected for OAuth 2.0 in both standards developing organizations, 3GPP and ETSI. + +### 6.5.2 Solution details + +The roles defined in OAuth 2.0 has been assigned as follows: + +- Resource owner / Resource server (producer): Near-RT RIC platform modules providing services via APIs. +- Client (consumer): xApp +Note.- xApp as API producer is FFS in current RIC Architecture specification. +- Authorization server: Security function in Near-RT RIC platform + +Grants shall be of the type Client Credentials Grant, as described in clause 4.4 of RFC 6749 [11], and represented in the following diagram: + +![](b3687f908deff19754c146afdccd390f_img.jpg) + +``` + ++---------+ +---------------+ +| |>--(A)- Client Authentication --->| Authorization | +| Client | | Server | +| |<--(B)---- Access Token ---------<| | ++---------+ +---------------+ + +``` + +**Figure 6.5-1-- from RFC 6749** + +3GPP SBA specifies in [13] that access tokens shall be JSON Web Tokens as described in RFC 7519 [18], and are secured with digital signatures or Message Authentication Codes (MAC) based on JSON Web Signature (JWS) as described in RFC 7515 [18]. ETSI MEC can also use JWT, that may include scopes of roles to restrict the access to MEC services. They may be signed to become tamper proof and encrypted. In general, the use + +O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00 + +of JWTs as access tokens in Near-RT RIC will depend on the final specification for network API solutions by O-RAN WG3. + +The authorization process entails two verifications: + +- Check whether the consumer is permitted to discover the requested Near-RT RIC API via the Enablement Discovery API during the discovery procedure. This is performed on per consumer granularity by the authorization server +- Check whether the consumer is permitted to access the requested service producer for consuming the service (e.g. SDL fetch data), on a per request type and corresponding subscription. The granularity is determined by the service logic of the producer. + +Management module of Near-RT RIC platform maintains the information of available producers and their supported services, as each of them needs to register the list of services it supports. + +The following schema represents the main steps of the entire authorization process: + +![Figure 6.5-2-- OAuth 2.0 process in Near-RT RIC](04001b31b76b02392fb8f58a556bf181_img.jpg) + +A diagram showing the OAuth 2.0 process in Near-RT RIC with four main entities: Security function OAuth server, Management, Consumer NF (e.g. xApp), and Near-RT RIC Services. The steps are numbered 1 to 4: + +- Registration of services:** Producers (Near-RT RIC platform) register services/capabilities at the Management service. +- Discovery (static or via access tokens):** Consumer obtains a list of candidate NFs via a query to Oauth server. +- Delivery of access tokens:** Consumer obtains the scope of accessible services. +- Selection:** Consumer selects one of the candidate producers. + +Figure 6.5-2-- OAuth 2.0 process in Near-RT RIC + +**Figure 6.5-2-- OAuth 2.0 process in Near-RT RIC** + +The overall OAuth 2.0 process is foreseen to take place after xApp registration and API discovery procedures specified in Near-RT RIC. The main steps would be: + +- Registration procedure in Management service of Near-RT RIC platform + - o xApp registration + - Note 1. Solution #1 adds a security validation feature in this process. + - Note 2. During the proposed registration/validation process the platform may check whether the xApp is provided by 3rd party or is RIC-owned application. + - o APIs registration by the producer via Enablement API +- Enablement API related procedures + - o Discovery + - Basic: Static restriction based on the registration information in database + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 37 + +- Optional: Protection of Discovery services by OAuth 2.0, e.g. in case of 3rd party xApps +- OAuth 2.0 based authorization + - Services offered by the Near-RT RIC platform are described in the scope of the access token provided to the xApp, required to use the specified APIs. + +### 6.5.3 Evaluation + +The proposed authorization framework addresses the key issues #1, #2, #4, #5, #6, #7, #8, #9, #10, #11 + +Note. The authorization mechanisms described in the solution may be applicable to other O-RAN parts of the architecture. + +## 6.6 Solution #5: Near-RT RIC database and SDL access control mechanisms + +### 6.6.1 Introduction + +OAuth 2.0 as described in Solution 4 is used to ensure authorized xApp access to SDL API. Additional steps need to be implemented to control granularity for the database access and that is considered in this solution. + +This solution implements Role-Based Access Control (RBAC) to control and restrict xApp access to the information stored in the Near-RT RIC database(s) and accessible via SDL APIs. Under RBAC, xApps would access the database(s) according to their assigned role, and the assigned role determines what operations the xApp can perform on what database. + +### 6.6.2 Solution details + +The solution is comprised of separate steps during the Onboarding to SMO process and during the SDL Registration process. RBAC roles are assigned during the onboarding process where privileges are defined by the xApp Solution Provider by a xApp database “token” and vetted by the Service Provider. The token needs granularity for data and operations in order to control access. + +![Diagram illustrating the xApp database token during onboarding process. The process involves three main components: xApp Solution Provider, Service Provider, and SMO. 1. xApp database 'token' is sent from the xApp Solution Provider to the Service Provider. 2. The Service Provider validates the xApp database 'token'. 3. The validated xApp database 'token' is then sent from the Service Provider to the SMO.](4ff48b1304b701cbb54dcd647087433e_img.jpg) + +``` + +sequenceDiagram + participant xAppSolutionProvider as xApp Solution Provider + participant ServiceProvider as Service Provider + participant SMO as SMO + + xAppSolutionProvider->>ServiceProvider: 1. xApp database "token" + activate ServiceProvider + ServiceProvider->>ServiceProvider: 2. Validates xApp database "token" + deactivate ServiceProvider + ServiceProvider->>SMO: 3. xApp database "token" + deactivate ServiceProvider + +``` + +Diagram illustrating the xApp database token during onboarding process. The process involves three main components: xApp Solution Provider, Service Provider, and SMO. 1. xApp database 'token' is sent from the xApp Solution Provider to the Service Provider. 2. The Service Provider validates the xApp database 'token'. 3. The validated xApp database 'token' is then sent from the Service Provider to the SMO. + +**Figure 6.6-1— xApp database token during onboarding** + +As part of the xApp onboarding to SMO process: + +1. The xApp Solution Provider generates a database “token” that declares what kind of database access and operations the xApp would need. This is sent to the Service Provider along with the xApp. +2. The Service Provider vets the proposed database access and operations during xApp validation by agreeing to the access rights requested by the xApp. +3. The database “token” is passed to the SMO when the xApp is onboarded. + +Before accessing the database, the xApp must register with the SDL using the SDL Client Registration procedure. This solution adds in an access authorization step before the xApp is allowed to register with the SDL. The Security Function uses the xApp database token to identify which roles the xApp is authorized for. + +![Sequence diagram of the Modified SDL Client Registration Procedure. The diagram shows an xApp interacting with an SDL within the Near-RT RIC Platform. The SDL interacts with a Security Function and a Database. The steps are: 1. xApp sends '1. SDL Client Registration request' to SDL. 1a. SDL sends '1a. Client authorization request' to Security Function. 1b. Security Function performs access authorization for xApp (highlighted in yellow). 1c. Security Function sends '1c. Client authorization response' to SDL. 2. SDL sends '2. Register to Database (if successful)' to Database. 3. SDL sends '3. SDL Client Registration response' to xApp.](f705517b50a73bc3abd6880a25451c55_img.jpg) + +``` + +sequenceDiagram + participant xApp + participant SDL + participant SecurityFunction as Security Function + participant Database + + Note over xApp, SDL: 1. SDL Client Registration request + xApp->>SDL: 1. SDL Client Registration request + Note over SDL, SecurityFunction: 1a. Client authorization request + SDL->>SecurityFunction: 1a. Client authorization request + Note over SecurityFunction: 1b. Security Function performs access authorization for xApp + SecurityFunction-->>SDL: 1c. Client authorization response + Note over SDL, Database: 2. Register to Database (if successful) + SDL->>Database: 2. Register to Database (if successful) + Note over SDL, xApp: 3. SDL Client Registration response + SDL-->>xApp: 3. SDL Client Registration response + +``` + +Sequence diagram of the Modified SDL Client Registration Procedure. The diagram shows an xApp interacting with an SDL within the Near-RT RIC Platform. The SDL interacts with a Security Function and a Database. The steps are: 1. xApp sends '1. SDL Client Registration request' to SDL. 1a. SDL sends '1a. Client authorization request' to Security Function. 1b. Security Function performs access authorization for xApp (highlighted in yellow). 1c. Security Function sends '1c. Client authorization response' to SDL. 2. SDL sends '2. Register to Database (if successful)' to Database. 3. SDL sends '3. SDL Client Registration response' to xApp. + +**Figure 6.6-2 – Modified SDL Client Registration Procedure from [3]** + +1. The xApp sends SDL Client Registration request to the SDL to access the database in the Near-RT RIC Platform. + - a. After the receipt of the request, the SDL sends a client authorization request to the Security Function. + - b. The Security Function performs access authorization for the xApp by comparing the database “token” from the xApp with the one validated by the Service Provider. After verification, the security function will assign the xApp a role based on the token. + - c. The Security Function sends a client authorization response to SDL. +2. SDL arranges with the database the permission for the xApp to access the database (if authentication is successful). +3. The SDL sends the response of successful or failed registration to the xApp. + +### 6.6.3 Evaluation + +This solution addresses key issue #7 Data protection and privacy in Near-RT RIC Database(s), and key issues #4, #5, #6. + +## 6.7 Solution #6: Security Logging (part of FCAPS) + +*NOTE: Security Logging will be tackled in dedicated Work Item study to Security Log Management within O-RAN Security Focus Group* + +### 6.7.1 Introduction + +*Void* + +### 6.7.2 Solution details + +*Void* + +### 6.7.3 Evaluation + +*Void* + +## 6.8 Solution #7: Access control mechanism for API repository/registry + +### 6.8.1 Introduction + +Near-RT RIC architecture specification [3] provides the following requirement in clause 5.1.3: *‘Near-RT RIC shall provide means to restrict xApps from discovery some published APIs based on configured policies.’* + +The same specification in clause 6.2.8 describes the API Enablement function, which provides the discovery service as well as repository/registry services for the Near-RT RIC APIs. + +*‘API Enablement provides support for registration, discovery and consumption of Near-RT RIC APIs within the Near-RT RIC scope. In particular, the API enablement services include:* + +- *Repository / Registry services for the Near-RT RIC APIs;* +- *Services that allow discovery of the registered Near-RT RIC APIs;* +- *Services to authenticate xApps for use of the Near-RT RIC APIs;* +- *Services that enable generic subscription and event notification;* +- *Means to avoid compatibility clashes between xApps and the services they access.* + +*The API enablement services can be accessed by the xApps via one or more enablement APIs.* + +*NOTE: The provided enablement APIs may need to consider the level of trust related to the xApp (e.g. 3rd party xApp, RIC-owned xApp, etc.)’* + +The proposed solution addresses: + +- The access control to API enablement function providing API authentication and authorization mechanisms. +- The level of trust related to the xApp via a secure onboarding and deployment of xApps in Near-RT RIC platform. + +### 6.8.2 Solution details + +API authentication (mutual TLS) and authorization (OAuth 2.0) mechanisms, providing the necessary access control to API Enablement function, are described in solutions #3 and #4 of the present document respectively. + +Secure onboarding and deployment procedure of xApps in Near-RT RIC, considers the level of trust related to the xApp by ensuring that the xApp comes from a valid solution provider and is integrity protected. The solution is described in solution #1 of the present document. + +### 6.8.3 Evaluation + +Solutions #1, #3 and #4 of the present address the security requirements related to API Enablement function coming from the Near-RT RIC architecture [3] in clauses 5.1.3 and 6.2.8, specifically related to access control and considerations around the level of trust of xApps. Key issues #4, #7, #8, #10 and #11 are addressed by the solution. + +## 6.9 Solution #8: Secure mechanisms for E2 interface + +### 6.9.1 Introduction + +Secure mechanisms for E2 interface are provided in existing WG11 specifications, in particular in O-RAN.WG11.O-RAN-Security-Requirements-Specifications [2], clause 5.2.4. + +### 6.9.2 Solution details + +Refer to O-RAN.WG11.O-RAN-Security-Requirements-Specifications [2], clause 5.2.4. + +### 6.9.3 Evaluation + +NOTE: Authorization solutions to access E2 nodes and associated services by xApps are for further study. Security mechanisms for E2 interface address key issues #3, #5 and #10. + +## 6.10 Solution #9: Secure mechanisms for A1 interface + +### 6.10.1 Introduction + +The Near-RT RIC receives policies from the Non-RT RIC across the A1 interface. While the A1 interface is considered secure with controls that provide confidentiality, integrity, and mutual authentication, the Near-RT RIC should not assume that the policies are valid and trusted. The Near-RT RIC should provide security built-in compliant with a zero-trust architecture based upon the principle that perimeter security is insufficient to protect against internal threats. + +NOTE: A1 related security mechanisms will be tackled in Non-RT RIC Security technical report (to be released) + +### 6.10.2 Solution details + +Security controls for the Near-RT-RIC that could be implemented as part of its A1 Termination include: + +1. Check policies received on A1 conform to defined schema. See also clause 6.13, Solution #12: A1 Policy Authentication of the present document. +2. Validate policy values for validity and range +3. Provide rate limiting on A1 to prevent resource exhaustion and DoS +4. Implement security logging for each of the above failure events + +### 6.10.3 Evaluation + +The solution addresses key issues #9 and #6 + +## 6.11 Solution #10: Secure mechanisms for O1 interface + +### 6.11.1 Introduction + +Secure mechanisms for O1 interface are provided in existing O-RAN specifications, in particular in O-RAN.WG1.O-RAN-Security-Requirements-Specifications [2], clause 5.2.2. + +### 6.11.2 Solution details + +Refer to O-RAN.WG11.O-RAN-Security-Requirements-Specifications [2], clause 5.2.2. + +### 6.11.3 Evaluation + +NOTE: xApps are managed via Near-RT RIC, not directly by SMO. Adequacy of existing security mechanisms specified for O1 in management of xApps is for further study. Key issue #4 is addressed by O1 security mechanisms. + +## 6.12 Solution #11: Mitigation for conflicting xApps + +### 6.12.1 Introduction + +WG3 has already defined a process to seek guidance from the Near-RT RIC Conflict Mitigation function prior to initiating a RIC function procedure. The purpose of the Conflict Mitigation function is to resolve potentially overlapping or conflicting request from multiple xApps. These are currently optional procedures [3]. + +This guidance can be initiated by 4 different actors at different points in the life cycle of an xApp: + +- Initiated by an authorized xApp +- Initiated by Subscription Management function + +- Initiated by message monitoring by the Conflict Mitigation function +- Initiated by Conflict Mitigation function + +For these procedures, the assumption from WG3 is that the Conflict Mitigation function has access to sufficient information to detect a potential conflict and take a decision on an optimal mitigation solution [3]. + +### 6.12.2 Solution details + +This solution proposes to make the first procedure, Conflict Mitigation guidance initiated by an authorized xApp, **mandatory** during the E2 Subscription procedure, which is performed at the end of xApp Registration. The E2 Subscription procedure is detailed in [3] in Section 9.3.2.1, with the xApp initiated E2 Guidance Request procedure described in Section 9.3.3.1 [3]. + +Performing this guidance request during xApp Registration would mitigate conflicts arising from newly deployed xApps. Additional consideration is needed for conflicts arising after deployment, once additional Conflict Mitigation messages and procedures are defined in WG3. + +### 6.12.3 Evaluation + +The solution addresses key issue #3. + +## 6.13 Solution #12: A1 Policy authentication + +### 6.13.1 Introduction + +A1 policies are provided by the Non-RT RIC to the Near-RT RIC over the A1 interface, which already has security protections as defined in [2]. The security control for the A1 interface is TLS at the transport layer. In addition, the Near-RT RIC APIs include A1 related APIs for A1 Policy Setup, Update, and Delete procedures [3]. Security for these APIs is considered in key issues 10 and 11 and solutions 3, 4, and 13 of this technical report. + +### 6.13.2 Solution details + +For a malicious A1 policy to successfully affect the Near-RT RIC, the policy first must contain a valid policy type supported by the Near-RT RIC, in order to pass the policy type check at the A1 Termination in the Near-RT RIC. The policy must then be mapped to an xApp in the Near-RT RIC. Finally, to exploit an xApp for malicious intent as described in Key Issue 9, the A1 policy needs to have capabilities to execute any of the security threats outlined. The access and knowledge required to complete this sequence of events implies a skilled adversary. + +Securing the endpoints of the A1 interface is another factor in preventing xApp exploitation by malicious A1 policies. This work item (WG3Sec) in WG11 addresses the Near-RT RIC side of the A1 interface. On the other end, the requirements and security controls for the SMO are FFS for the WG11 Security Requirements specification, but there is a newly started work item (SecureNonRTRIC) to secure the Non-RT RIC in the SMO. This new work item will address the security and data privacy of the Non-RT RIC, A1 interface, R1 interface, and external interfaces. + +With the A1 interface itself secured, security of the A1 interface endpoints in progress, A1 related APIs security in progress for authentication and authorization, and the challenges of generating a malicious policy, the likelihood of xApp exploitation via malicious A1 policies is judged to be very low. Further examination of this issue should be performed upon completion of the relevant WG11 work items, but at the moment, no additional A1 policy authentication is deemed necessary. + +### 6.13.3 Evaluation + +This solution describes the protections against the security threats in key issue #9. + +## 6.14 Solution #13: Network Security layer for APIs + +### 6.14.1 Introduction + +The following network layers are being proposed for the Network APIs in Near-RT RIC by O-RAN WG3: + +| RIC API | NATURE | NETWORK API SOLUTION (PROTOCOL/ MESSAGE ENCODING) | | +|--------------------------------------------------------------------------------------|-------------------------------|---------------------------------------------------|-------------------| +| | | Default | Alternative (s) | +| A1 related APIs in A1 med towards xApp | | | | +| - Policy Enforcement API | Transactional | gRPC/Protobuf/JSON | | +| - Enrichment information API | Transactional | gRPC/Protobuf/JSON | | +| E2 related APIs in E2T/E2M towards xApp | | [SCTP/E2related/E2SM] | | +| - E2 Subscription
- E2 Subscription Delete
[- E2 Subscription Delete Required] | Transactional | SCTP/ Protobuf/ ASN.1 | HTTP/ JSON/ ASN.1 | +| - E2 Guidance | Transactional | SCTP/ Protobuf/ ASN.1 | HTTP/ JSON/ ASN.1 | +| - E2 Indication | Time critical Uni-Streaming | SCTP/ Protobuf/ ASN.1 | | +| - E2 Control | Time critical Bi-Streaming | SCTP/ Protobuf/ ASN.1 | | +| Management APIs | | | | +| - ML model related APIs | Transactional | For future study | | +| - FCAPS related APIs | Transactional | gRPC/Protobuf | | +| SDL APIs (store/ fetch/ notify/ push)
- R-NIB, UE-NIB, Other data | Transactional + Uni-streaming | For future study | | +| Enablement APIs | Transactional | gRPC/Protobuf | HTTP/ JSON | + +This solution proposes to add a security layer in the current network protocol stack for the different APIs specified in Near-RT RIC architecture. + +### 6.14.2 Solution details + +TLS is proposed as a solution for transactional Near-RT RIC APIs based on HTTP or HTTP/2. REST APIs use HTTP and support Transport Layer Security (TLS). REST APIs utilizes JavaScript Object Notation (JSON) as encoding protocol. gRPC APIs use HTTP/2 and support as well TLS. In contrast with REST APIs, gRPC used Protobuf as encoding protocol. Please refer to O-RAN Security Protocols [19] for TLS 1.2, TLS 1.3 specifications. + +IPsec is proposed as a preferred solution for time critical uni-streaming and bi-streaming E2 related APIs, which are based on SCTP. Please refer to O-RAN Security Protocols [19] for IPsec specifications. + +DTLS is proposed as optional solution for time critical uni-streaming and bi-streaming E2 related APIs, which are based on SCTP. The solution is currently on hold due to limitation of packet size when DTLS is running over SCTP (refer to RFC 6083). Please refer to O-RAN Security Protocols [19] for DTLS specifications. + +### 6.14.3 Evaluation + +Network Security layer for APIs shall be consider as a basic requirement in Near-RT RIC architecture. The choice will depend on the selected network protocol stacks. + +The solution addresses key issues #1, #2, #4, #5, #6, #7, #8, #9 and #10. + +## 6.15 Solution #14: Security procedure for xApp registration + +### 6.15.1 Introduction + +As part of the xApp registration procedure into the Near-RT RIC platform, the platform assigns an identity (ID) to the xApp, so called xApp ID. This xApp ID is used in xApp's API request messages to the Near-RT RIC platform to facilitate the Near-RT RIC platform the identification of the xApp (API service consumer). + +The solution proposes a mechanism to enhance the actual registration procedure by embedding the xApp ID into the provided certificate used for authentication (mTLS) and for authorization (OAuth – client authentication) according to the parametrization in [19]. + +NOTE 1: The proposed procedure is based on the security procedures specified in 3GPP TS 33.122 (Security aspects of Common API Framework (CAPIF) [31] for 3GPP northbound APIs), clause 6.1. + +Nevertheless, the implementation of the procedure does not require the implementation of the CAPIF framework in O-RAN Near-RT RIC platform. + +In addition, the solution proposes UUID (version 4) as xApp ID format, ensuring the uniqueness and randomness of the identifier. + +### 6.15.2 Solution details + +The procedure begins with a secure session between the xApp and Near-RT RIC platform using TLS, which uses server- side certificate authentication. It is assumed that there is a pre-provisioning of necessary parameters for registration during the onboarding/deployment process of the xApp, to allow the latter to reach the Near-RT RIC platform, authenticate it, and present a registration credential (e.g., OAuth 2.0 access token, message digest, etc.) that can be verified by the Near-RT RIC platform. + +NOTE 2: The configuration of the initial pre-provisioned registration credentials in the xApp as part of the deployment process are left to operator implementation. O-Cloud DMS is referred as a possible entity in charge of the provisioning task. + +With the secure session established, the xApp sends a registration request message to the Near-RT RIC platform (Management Function). The message carries the initial credential obtained during the pre-provisioning of the registration information, which may be an OAuth 2.0 access token. If OAuth 2.0 mechanism is used for initial credentials, it should be profiled as specified in [19]. Other type of credentials may also be used (e.g., message digest, pre-shared key) + +Figure 6.15.2-1 details the security information flow for the security procedure. The OAuth 2.0 token-based authentication initial registration credential is shown in this example. + +``` + +@startuml +participant xapp as "xApp\n[API service consumer]" +participant nfo as "Provisioning system\n(NFO in SMO)" +participant pf as "Near-RT RIC platform \n(Security function,\nRA functionality)\n[API service producer]" +participant pki as "Operator PKI\nCA" +xapp <- nfo : 1. Registration information\n(Near-RT RIC Platform/Security function\n(Address,Root CA Certificate),\n OAuth 2.0 Access token) +xapp -> pf : 2. TLS (Server side certificate based authentication) +note over xapp + 3. Generate the key pair + [private Key, public Key] +endnote +xapp -> pf : 4. Registration request (by xApp instance)\n[OAuth 2.0 access token, xApp Instance CSR] +note over pf + 5. Verify OAuth access token + Generate the xApp ID + POP (Proof of Possession of Private Key) + Embed xApp ID in the CSR (subjectAltname) +endnote +pf -> pki : 6. Enrolment protocol \n(e.g., CMPv2) +pf <- pki : 7. Issued certificate \n(embedded xApp ID) +note over pf + 8. Generate xApp MOI +endnote +xapp <- pf : 9. Registration Response (for xApp instance)\n[xApp ID, xApp Certificate, (service API authentication \nand Authorization information)] +@enduml + +``` + +![Sequence diagram showing the security procedure for xApp registration. The diagram involves four main entities: xApp (API service consumer), Provisioning system (NFO in SMO), Near-RT RIC platform (Security function, RA functionality) (API service producer), and Operator PKI CA. The steps are: 1. Registration information (Near-RT RIC Platform/Security function (Address, Root CA Certificate), OAuth 2.0 Access token) from Provisioning system to xApp. 2. TLS (Server side certificate based authentication) from xApp to Near-RT RIC platform. 3. Generate the key pair (private Key, public Key) from xApp. 4. Registration request (by xApp instance) (OAuth 2.0 access token, xApp Instance CSR) from xApp to Near-RT RIC platform. 5. Verify OAuth access token, Generate the xApp ID, POP (Proof of Possession of Private Key), Embed xApp ID in the CSR (subjectAltname) from Near-RT RIC platform. 6. Enrolment protocol (e.g., CMPv2) from Near-RT RIC platform to Operator PKI CA. 7. Issued certificate (embedded xApp ID) from Operator PKI CA to Near-RT RIC platform. 8. Generate xApp MOI from Near-RT RIC platform. 9. Registration Response (for xApp instance) (xApp ID, xApp Certificate, (service API authentication and Authorization information)) from Near-RT RIC platform to xApp.](2c78150856ba0875e8a096304863b445_img.jpg) + +``` + +sequenceDiagram + participant xApp as xApp +[API service consumer] + participant ProvisioningSystem as Provisioning system +(NFO in SMO) + participant NearRT RIC as Near-RT RIC platform +(Security function, +RA functionality) +[API service producer] + participant OperatorPKI as Operator PKI +CA + + ProvisioningSystem->>xApp: 1. Registration information +[Near-RT RIC Platform/Security function +(Address, Root CA Certificate), +OAuth 2.0 Access token] + xApp->>NearRT RIC: 2. TLS (Server side certificate based authentication) + xApp->>NearRT RIC: 3. Generate the key pair +[private Key, public Key] + xApp->>NearRT RIC: 4. Registration request (by xApp instance) +[OAuth 2.0 access token, xApp Instance CSR] + Note over NearRT RIC: 5. Verify OAuth access token +Generate the xApp ID +POP (Proof of Possession of Private Key) +Embed xApp ID in the CSR (subjectAltname) + NearRT RIC->>OperatorPKI: 6. Enrolment protocol +(e.g., CMPv2) + OperatorPKI-->>NearRT RIC: 7. Issued certificate +(embedded xApp ID) + Note over NearRT RIC: 8. Generate xApp MOI + NearRT RIC-->>xApp: 9. Registration Response (for xApp instance) +[xApp ID, xApp Certificate, (service API authentication +and Authorization information)] + +``` + +Sequence diagram showing the security procedure for xApp registration. The diagram involves four main entities: xApp (API service consumer), Provisioning system (NFO in SMO), Near-RT RIC platform (Security function, RA functionality) (API service producer), and Operator PKI CA. The steps are: 1. Registration information (Near-RT RIC Platform/Security function (Address, Root CA Certificate), OAuth 2.0 Access token) from Provisioning system to xApp. 2. TLS (Server side certificate based authentication) from xApp to Near-RT RIC platform. 3. Generate the key pair (private Key, public Key) from xApp. 4. Registration request (by xApp instance) (OAuth 2.0 access token, xApp Instance CSR) from xApp to Near-RT RIC platform. 5. Verify OAuth access token, Generate the xApp ID, POP (Proof of Possession of Private Key), Embed xApp ID in the CSR (subjectAltname) from Near-RT RIC platform. 6. Enrolment protocol (e.g., CMPv2) from Near-RT RIC platform to Operator PKI CA. 7. Issued certificate (embedded xApp ID) from Operator PKI CA to Near-RT RIC platform. 8. Generate xApp MOI from Near-RT RIC platform. 9. Registration Response (for xApp instance) (xApp ID, xApp Certificate, (service API authentication and Authorization information)) from Near-RT RIC platform to xApp. + +**Figure 6.15.2-1: Security procedure for xApp registration** + +1. As a pre-requisite to the registration procedure, the xApp obtains information from a provisioning system (NFO in SMO) during the onboarding/deployment phase in the infrastructure. This information is used to authenticate and establish a secure TLS communication with the Near-RT RIC platform during the registration process. The information includes details of the Near-RT RIC platform (address, Root CA certificate) and includes an initial registration credential (the OAuth 2.0 Access token in the example). + +2. The xApp and Near-RT RIC platform (e.g., Security function and/or Management function) establish a secure session based on TLS (server-side certificate authentication). The xApp uses the information obtained in step 1 to establish the TLS session. + +Editor's Note: if TLS communication should be mandatory in the procedure is ffs. + +Editor's Note: the termination point of the TLS communication in Near-RT RIC platform (e.g. Management Function, Security Function) is ffs. + +3. The xApp generates the key pair, i.e., private key and public key + +4. After successful establishment of the TLS session, the xApp instance sends a registration request message to the Near-RT RIC platform along with the pre-provisioned initial registration credential (OAuth 2.0 token in the example), and the xApp instance public key in corresponding CSR (Certificate Signing Request) message. + +5. The Near-RT RIC platform (e.g., via Security function) should validate the initial registration credential and the Management Function of the platform should generate an xApp ID for that particular xApp instance. At the reception of the CSR message from the xApp, the Near-RT RIC platform (e.g., via Security function), acting as a Registration Authority (RA), should prove that the xApp instance is in possession of the private key, and if the proof of possession procedure is positive, it should embed the xApp ID in the CSR message to be forwarded to the Operator CA. The RA may use an enrolment protocol (e.g., CMPv2) to fetch the certificate from the CA + +NOTE 3: Authentication mechanism between RA and CA are part of the operator PKI implementation. + +6. Fetching the certificate (e.g., enrolment protocol such as CMPv2) + +7. Operator CA issues a certificate, embedding the xApp ID in subjectAltName field. The issued certificate by the operator CA will be used by the xApp for subsequent authentication and authorization procedures between the xApp and the Near-RT RIC platform when services/resources are consumed by xApps via APIs. + +8. The Near-RT RIC platform (Management Function) generates an xApp Managed Object Instance (MOI) as specified in [3], which may contain the mechanism for authentication (e.g., mTLS) and authorization (e.g., OAuth 2.0) between the xApp and the corresponding module of the Near-RT RIC platform. + +9. The Near-RT RIC platform (Management Function) responds with a xApp registration response message. The response should include the assigned xApp ID, authentication and authorization mechanism if provided in step 5 and xApp certificate. + +The solution proposes for the data type of the xApp ID a string that uniquely identifies the xApp instance. The format of this string should be a Universally Unique Identifier (UUID) version 4 (as described in IETF RFC 4122) + +The solution proposes that subjectAltName in the xApp instance certificate should contain a URI-ID with the URI for the xApp ID as an URN; this URI-ID should contain the xApp ID of the xApp instance using the UUID format as described in IETF RFC 4122 (e.g., urn:uuid:f81d4fae-7dec-11d0-a765-00a0c91e6bf6) + +### 6.15.3 Evaluation + +The following diagram shows a proposal to insert the security procedure in the existing registration procedure specified in O-RAN.WG3.RICARCH, clause 9.1.4, where xApp ID is assigned: + +``` +@startuml +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid + +participant smo as "SMO" +Box "O-Cloud" +participant dms as "DMS" +endbox +participant xApp as "xApp" +Box "Near-RT RIC Platform" +participant olt as "O1 Termination" +participant ms as "Management Function + Security Function" +endbox + +dms -> xApp : 0. Pre-provisioning of registration information +``` + +``` + +xApp <-> ms : TLS session +xApp -> ms : 1. <> registration request (initial credentials) + +rnote over olt, ms + 2. registration processing, validate, + assign xApp ID and bind it to xApp certificate, + create xApp MOI +endnote + +ms -> xApp : 3. <> registration response + +Opt If SMO has subscribed +olt -> smo : 4. <> Notify MOI Creation +End + +@enduml + +``` + +![Sequence diagram showing the xApp registration process with security procedure. The diagram involves SMO, O-Cloud (DMS), xApp, and Near-RT RIC Platform (O1 Termination, Management Function + Security Function). Step 0: Pre-provisioning of registration information from DMS to xApp. Step 1: xApp sends registration request to O1 Termination. Step 2: O1 Termination sends registration request to Management Function + Security Function for processing. Step 3: Management Function + Security Function sends registration response to O1 Termination. Step 4 (optional): O1 Termination sends Notify MOI Creation to SMO if SMO has subscribed.](27927bdca1769fed46cae1d4c94911d3_img.jpg) + +``` + +sequenceDiagram + participant SMO + participant OCloud as O-Cloud + participant DMS + participant xApp + participant O1Termination as O1 Termination + participant MF as Management Function + Security Function + + DMS->>xApp: 0. Pre-provisioning of registration information + xApp->>O1Termination: 1. <> registration request (initial credentials) + O1Termination->>MF: 2. registration processing, validate, assign xApp ID and bind it to xApp certificate, create xApp MOI + MF-->>O1Termination: 3. <> registration response + opt [If SMO has subscribed] + O1Termination->>SMO: 4. <> Notify MOI Creation + end + +``` + +Sequence diagram showing the xApp registration process with security procedure. The diagram involves SMO, O-Cloud (DMS), xApp, and Near-RT RIC Platform (O1 Termination, Management Function + Security Function). Step 0: Pre-provisioning of registration information from DMS to xApp. Step 1: xApp sends registration request to O1 Termination. Step 2: O1 Termination sends registration request to Management Function + Security Function for processing. Step 3: Management Function + Security Function sends registration response to O1 Termination. Step 4 (optional): O1 Termination sends Notify MOI Creation to SMO if SMO has subscribed. + +Figure 6.15.3-1: xApp registration process with Security procedure + +## 6.16 Solution #15: Security requirement proposals for Y1 interface + +### 6.16.1 Introduction + +The O-RAN architecture description document [32] explains that Y1 services can only be consumed by Y1 consumers after mutual authentication and authorization. That would imply that the result of the authentication for the duration of communications must be maintained, e.g. by integrity protection and/or encryption with a key that is derived from the authentication and is unknown to the adversary. + +In the ongoing discussion two types of APIs are being discussed: + +- RAI API: API internal to the Near-RT RIC +- Y1 API: API exported by the Y1T (Y1 Termination) to consumers outside of the Near-RT RIC (the Y1 consumers) + +The RAI API is identical to other Near-RT RIC APIs regarding its requirements on security, so key issues #10 (see 5.11) and #11 (see 5.12) as well as solutions #3 (see 6.4), #4 (see 6.5), #7 (see 6.8) and #13 (see 5.14) apply. + +In discussion two types of scenarios are related to the Y1 interface, involving a new entity called Y1T inside the Near RT RIC platform, providing a provider interface to be consumed by external Y1 consumers [34]: + +- type 1a: Y1T consumes RAI and exposes externally to Y1 consumers +- type 2b: Near-RT RIC platform generates RAI and exposes it to ETSI MEC, as the source of Radio Network Information Service (RNIS) + +![Figure 6.16-1: Scenarios relevant to the Y1 interface security. The diagram shows two scenarios, 1a and 2b, within a 'Near-RT RIC' box. In scenario 1a, 'Y1 Consumers' connect to 'Y1T' via 'Y1 API(s)', and 'Y1T' connects to 'RAI producer xApp' via 'RAI API(s)'. In scenario 2b, 'ETSI MEC' connects to 'Y1T' via 'Y1 API(s)', and 'Y1T' connects to 'some platform module' via 'RAI API(s)'.](87e79467a06d61dd357b91ea09704de3_img.jpg) + +``` + +graph TD + subgraph "scenario type 1a" + Y1Cons[Y1 Consumers] + subgraph "Near-RT RIC (1a)" + Y1T1[Y1T] + RAIProd[RAI producer xApp] + end + Y1Cons -- "Y1 API(s)" --> Y1T1 + Y1T1 -- "RAI API(s)" --> RAIProd + end + + subgraph "scenario type 2b" + ETSIMEC[ETSI MEC] + subgraph "Near-RT RIC (2b)" + Y1T2[Y1T] + PlatformMod[some platform module] + end + ETSIMEC -- "Y1 API(s)" --> Y1T2 + Y1T2 -- "RAI API(s)" --> PlatformMod + end + +``` + +Figure 6.16-1: Scenarios relevant to the Y1 interface security. The diagram shows two scenarios, 1a and 2b, within a 'Near-RT RIC' box. In scenario 1a, 'Y1 Consumers' connect to 'Y1T' via 'Y1 API(s)', and 'Y1T' connects to 'RAI producer xApp' via 'RAI API(s)'. In scenario 2b, 'ETSI MEC' connects to 'Y1T' via 'Y1 API(s)', and 'Y1T' connects to 'some platform module' via 'RAI API(s)'. + +**Figure 6.16-1 Scenarios relevant to the Y1 interface security** + +Based on the ongoing discussion it can be assumed that the topology of the PLMN trust domain should be hidden from the Y1 consumers accessing the Y1 services from outside the PLMN trust domain. + +### 6.16.2 Solution details + +The following proposals for requirements have been derived from [31], clause 4. + +- The Y1 interface shall provide mechanisms to authenticate the Y1 consumer and allow for the Y1 consumer to authenticate the Y1 provider (mutual authentication) +- The Y1 interface shall authorize the Y1 consumer before allowing access to any Y1 service +- The Y1 interface shall provide mechanisms to provide confidentiality and integrity protection for all data exchanged +- The Y1 interface shall provide replay- protection for all data exchanged +- The Y1 interface shall enforce the result of the authentication for the duration of communications (e.g. by integrity protection or implicit authentication by encryption with a key that is derived from the authentication and is unknown to the adversary). +- Y1T shall provide mechanisms to hide the topology of the PLMN trust domain from the Y1 consumers accessing the Y1 services from outside the PLMN trust domain +- Further security controls for the Near-RT-RIC that could be implemented as part of its Y1T include: + 1. Validate received values for validity and range + 2. Provide rate limiting on Y1 interface to prevent resource exhaustion and DoS + 3. Implement security logging for each of the above failure events + +### 6.16.3 Evaluation + +This solution addresses key issue #13 of the present document. + +## 6.17 Solution #16: Additional security measures for the E2 interface + +### 6.17.1 Introduction + +The Near-RT RIC receives Near real-time information from the E2 Nodes across the E2 interface. While the E2 interface is considered secure with controls that provide confidentiality, integrity, and mutual authentication, the Near-RT RIC should not assume that the data received is valid and trusted. The Near-RT RIC should provide built-in security compliant with a zero-trust architecture based upon the principle that perimeter security is insufficient to protect against internal threats. + +### 6.17.2 Solution details + +Security controls for the Near-RT-RIC that could be implemented as part of its E2 Termination include: + +1. Validate received values for validity and range +2. Provide rate limiting on E2 interface to prevent resource exhaustion and DoS +3. Implement security logging for each of the above failure events + +### 6.17.3 Evaluation + +The solution addresses key issue #14. + +## 6.18 Solution #17: Standard Identity management of xApp during xApp Registration Procedure. + +### 6.18.1 Introduction + +The Near-RT RIC platform identifies and assigns a xApp ID to the xApp that is being deployed on its platform. However, there is no universally established identity for applications in a cloud native environment that can be used by a program and other mechanisms are more suitable to identify workloads in a cloud native environment. + +The solution proposes to use SPIFFE— Secure Production Identity Framework which is a universal service identity control plane designed for cloud-native and zero-trust based architectures. + +This is also in adherence to **NIST SP 800-207A** [41] which mentions that “service identity should not be subjected to spoofing and should be continuously verifiable. An example of workload identity is a SPIFFE ID which is encoded as a Uniform Resource Identifier (URI) and carried in a cryptographically verifiable document called a SPIFFE Verifiable Identity Document (SVID). “ + +SPIRE is a production-ready implementation of SPIFFE APIs that uses Node and workload attestation to securely issue SVIDs [X.509 certificate with SPIFFE ID] to Applications. + +The main modules of the SPIFFE Specifications that are being used in the solution are: + +1. SPIFFE ID: Standard URI format based on RFC 3986 with certain conditions. +[EXAMPLE: spiffe://domain-name/clusterName/namespace/xAppName] + +2. SVID (SPIFFE verifiable Identity document): Cryptographically verifiable document used to prove a service's identity to a peer. It uses existing formats which are X509 certificates and JWT tokens. +3. Trust bundle: The CA certificate chain (root certificate and intermediate certificates) which entities use to verify the SVID. +4. SPIRE Agent and SPIRE Server: SPIRE Agent deployed on the Node where xApp is deployed. SPIRE Server module is deployed in the Near-RT RIC Platform. +5. Optional Certificate side-car/ [SPIFFE Helper] container along with xApp Instance Pod for handling key and certificate management. + +As part of the xApp registration procedure into the Near-RT RIC platform, the xApp instance will use the SPIFFE ID for registering into the Near-RT RIC platform and will allow the platform to interpret the identity of the xApp instance via the structured SPIFFE ID format. + +![Diagram of the Secured xApp Registration Procedure using SPIRE. The diagram shows a Node containing an xApp instance pod with an xApp instance and a Certificate sidecar. A SPIRE Agent is also on the Node. The xApp instance pod sends a 'Secured xApp Registration procedure' message to the SPIRE Server in the Near RT-RIC platform. The message contains 'xApp ID== SPIFFE ID' and 'SVID=X.509 certificate with xApp ID in SAN field.'. The Near RT-RIC platform also contains a RIC App. An SMO (Service Management Orchestrator) is connected to the RIC App. An Operator CA is connected to the SPIRE Server. A table titled 'Registration Entries' shows the SPIFFE ID format: 'Name=xAppDescriptor', 'xApp name, vendor, software version, any Operator customized Kubernetes deployment information.', and 'spiffe://rakuten.com/clusterName/names pace/xAppName'.](46b7ee71831dd713ce8b69a688db5ede_img.jpg) + +| Registration Entries | | +|----------------------|-------------------------------------------------------------------------------------------------| +| SPIFFE ID | Name=xAppDescriptor | +| | xApp name, vendor, software version, any Operator customized Kubernetes deployment information. | +| | spiffe://rakuten.com/clusterName/names pace/xAppName | + +Diagram of the Secured xApp Registration Procedure using SPIRE. The diagram shows a Node containing an xApp instance pod with an xApp instance and a Certificate sidecar. A SPIRE Agent is also on the Node. The xApp instance pod sends a 'Secured xApp Registration procedure' message to the SPIRE Server in the Near RT-RIC platform. The message contains 'xApp ID== SPIFFE ID' and 'SVID=X.509 certificate with xApp ID in SAN field.'. The Near RT-RIC platform also contains a RIC App. An SMO (Service Management Orchestrator) is connected to the RIC App. An Operator CA is connected to the SPIRE Server. A table titled 'Registration Entries' shows the SPIFFE ID format: 'Name=xAppDescriptor', 'xApp name, vendor, software version, any Operator customized Kubernetes deployment information.', and 'spiffe://rakuten.com/clusterName/names pace/xAppName'. + +Figure 6.18.1-1: Secured xApp Registration Procedure using SPIRE. + +### 6.18.2 Solution details + +The steps outlining the solution are elaborated below. + +Step 1: Define the Actors and Roles in the xApp Registration Procedure and the Pre-requisite. + +- xApp Instance Pod: xApp Application, (optional) Certificate Side Car originator for certificate and key management. +- SPIRE Agent: To oversee identity management and conduct workload verification within the system. +- SPIRE Server in Near-RT RIC platform: handles the registration-related message from/to xApp. A central component responsible for managing identities and issuing identity credentials. + +Pre-requisites: As a pre-requisite, the xApp Instance Node should have the information details of the Near-RT RIC platform (IP address, Trust anchors) from the provisioning system. + +Step 2: **Node Attestation**: SPIRE Agent and SPIRE Server Secured channel establishment. + +- 2.i SPIRE Agent initiates the mTLS with the SPIRE Server for its attestation. SPIRE Agent uses the Node certificates in this step which can be Kubernetes issued or Operator signed certificates. Step 2.ii to 2.iv details the procedures for Nodes Certificates signed by Operator CA. +- 2.ii SPIRE Server responds back to SPIRE Agent with its own certificate and chain. +- 2.iii The SPIRE Agent verifies the SPIRE server certificate and responds back with its own node certificate. +- 2.iv The x509pop node attestor plugin at the SPIRE Server verifies that the certificate is rooted to a trusted set of CAs and verifies that node is in possession of private key. The TLS connection gets successfully established. +- 2.v In case of Kubernetes issued certificates the additional steps from 2.vi to 2.ix should be followed. +- 2.vi SPIRE Server shall generate a CSR on behalf of the SPIRE Agent and send to the Operator CA for signing. +- 2.vii The Operator CA signs the CSR and sends the SVID [X.509 certificate with SPIFFE ID in the SAN field] to the SPIRE Server. +- 2.viii The SPIRE Server sends the TRUST Bundle to the SPIRE Agent over the existing mTLS connection. +- 2.ix The SPIRE Agent will re-establish the mTLS connection with the newly received SVID. + +NOTE: Steps 2.i to 2.iv are for Node Attestation using Node certificates signed by Operator CA. + +Step 2.v to 2.ix are for Node Attestation using Kubernetes issued Certificates. In such cases Kubernetes CA certificates are pre-configured in the SPIRE server. + +**Step3: Registration entries of Workload in SPIRE Server:** As mentioned in clause 6.2.2, the SMO maps the RIC variables and instructs the O-Cloud DMS to create the xApp Deployment and allocate the resources necessary on the Near-RT RIC. As a part of this procedure, the SMO should send the xApp Registration entries [Management Descriptor] via its O1 interface to the Near-RT RIC. It would map a structured SPIFFE ID to each xApp Instance and facilitate the Near-RT RIC to identify the xApp being deployed and manage its life cycle. + +NOTE: Also the SPIRE Server's Registration API, could be exposed to SMO for the SPIRE Server to obtain the workload Registration entries. + +EXAMPLE: Registration Entries of two xApp Instances + +| Registration Entries | | +|-------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------| +| SPIFFE ID | 1. Name=xAppDescriptor | +| spiffe://domain-name/clusterName/namespace/xAppName-1 | 2. xApp name-1, vendor, software version, containers, pod- label(label1), and any Operator customized Kubernetes deployment information. | +| spiffe://domain-name/clusterName/namespace/xAppName-2 | 3. xApp name-2, vendor, software version, containers, pod- label(label2), and any Operator customized Kubernetes deployment information. | + +Step 4: **Registration Entries in Agent for SVID Issuance:** SPIRE Server sends the workload (xApp) Registration entry details to the SPIRE agents registered on it. + +Step 5: **Workload Attestation:** Workload xApp Instance is instantiated. Also, an optional component of side-car container can be instantiated to handle the certificate and key management of xApp Instance which offloads the xApp Instance for security related functions. + +- 5.i The xApp Instance Pod communicates with the SPIRE Agent over a unix domain socket-based communication. +- 5.ii The SPIRE Agent utilizes a combination of kernel and user space calls to gather supplementary information about the workload. The SPIRE Agent interrogates the node's kernel to identify the process ID of the caller. It then invokes any configured workload attester plugins, providing them with the process ID of the workload. This process involves identifying the workload's pod ID through its cgroup association and subsequently obtaining information about the pod. +- 5.iii The agent introspects a workload to determine its properties, based on a set of selectors associated with it. +- 5.iv SPIRE Agent ascertains the identity of the workload by cross-referencing the discovered workload selectors with the Registration entries. + +Step 6. **Generate CSR:** On successful validation in step 5, the SPIRE Agent will generate the CSR and private key for each workload (xApp). The CSRs will have the SPIFFE ID in the SAN field. The SPIFFE agent derives the SPIFFE ID from the Registration entries in Step 4 which uniquely identifies each xApp instance. + +Step 7. SPIRE Agent sends xApp CSRs to the SPIRE server. + +Step 8. **CSR Signing:** SPIRE Server in turns sends the xApp CSRs to the Operator CA for signing. + +Step 9. **Operator PKI:** The Operator CA provides xApp SVID to the SPIRE Server. SVID are X.509 certificates with SPIFFE ID in the SAN field. + +Step 10. SPIRE Server sends xApp SVID [X.509 Certificates with SPIFFE ID] and trust bundle to the SPIRE Agent which it stores in memory for a short duration of time. + +Step 11. **Issuance of SVID:** SPIRE Agent then provides the xApp SVID, trust bundle to the certificate sidecar. The xApp Instance will then use the SVIDs for further communication like xApp Registration towards Near real-time RIC platform. + +NOTE: The xApp instance would establish a secure session with the Near-RT RIC as per the Pre-requisites mentioned in Step 1. + +Step 12: The xApp Instance sends Registration Request toward the Near-RT RIC platform over a secured TLS connection. The Near-RT RIC can validate the SAN field of the X.509 certificate of the xApp Instance against the Registration entries. + +Step 13. On successful validation, the Near-RT RIC platform responds with xApp registration response message with the xApp ID. + +Step 14. Optional: The Near-RT RIC informs SMO about the successful deployment of xApp. + +The solution proposes that xApp ID use a structured ID format of SPIFFE ID which can be interpreted programmatically. The mechanism introduced does not rely on information from xApp to determine the xApp ID. Unix socket-based communication is used for process-to-process communication within the Node. Optional side-car container for key and certificate management reduces the attack surface on the Applications. + +![Figure 6.18.2-1: x-App Registration procedure using SPIFFE Framework.](23872d06c8f12d9f68ca94b03a5275cc_img.jpg) + +Figure 6.18.2-1: x-App Registration procedure using SPIFFE Framework. + +Figure 6.18.2-1: x-App Registration procedure using SPIFFE Framework. + +### 6.18.3 Evaluation + +The following proposal uses a cloud native solution for service identity management of applications in a cloud native environment. This is in adherence to NIST 800-207A[41]. SPIRE is a production-ready implementation of SPIFFE APIs that uses Node and workload attestation to securely issue SVID (X.509 certificate with SPIFFE ID) to Applications which can be used for service-service communication. Using SPIRE Agent and SPIRE Server in an O-RAN environment, standardized identities can be provided to Applications like xApp. The SVID issued to xApp can be used to establish a secure connection with the Near-RT RIC platform and the xApp ID can be derived from the SAN field of the X.509 certificate. + +The three open item in the proposal have been listed below: + +1. The RICARCH [3] does not currently describe the initial configuration of Registration entries via the O1 interface from the SMO. This procedure would need to be defined. +2. The RICARCH [3] clause 9.4.1 assumes that the Near-RT RIC platform creates the xAppID. In this proposal, the Near-RT RIC is obtaining the xApp ID from SMO via Registration entries. Another alternative would be to read the SAN field of the xApp Instance certificate. +3. Handling of private keys in SPIRE Agent and SPIRE Server as an alternative to in-memory and disk-based. + +# 7. Conclusions + +## 7.1 Key Issue Solution Mapping + +This document currently contains 14 key issues and 17 solutions proposals to address or reduce the risk associated with the key issues. A mapping of the solutions to the key issues is shown here. + +| Key issue | Sol # 1 | Sol #2 | Sol #3 | Sol #4 | Sol #5 | Sol #6 | Sol #7 | Sol #8 | Sol #9 | Sol #10 | Sol #11 | Sol #12 | Sol #13 | Sol #14 | Sol #15 | Sol #16 | Sol #17 | +|----------------------------------------|---------|--------|--------|--------|--------|--------|--------|--------|--------|---------|---------|---------|---------|---------|---------|---------|---------| +| KI 1: Malicious xApps | X | X | X | X | | | | | | | | | X | X | | | X | +| KI 2: Compromised xApp | X | X | X | X | | | | | | | | | X | | | | | +| KI 3: Conflicting xApps | | | | | | | | X | | | X | | | | | | | +| KI 4: Compromise of xApp isolation | | | X | X | X | | X | | | X | | | X | | | | | +| KI 5: Compromise of ML data pipelines | | X | X | X | X | | | X | | | | | X | | | | | +| KI 6: Altering ML training models | | X | X | X | X | | | | X | | | | X | | | | | +| KI 7: Database protection and privacy | | | X | X | X | | X | | | | | | X | | | | | +| KI 8: Untrusted xApps | X | X | X | X | | | X | | | | | | X | | | | | +| KI 9: Malicious A1 policies | | | X | X | | | | | X | | | X | X | | | | | +| KI 10: RIC API authentication security | | | X | X | | | X | X | | | | | X | | | | | + +| Key issue | Sol # 1 | Sol #2 | Sol #3 | Sol #4 | Sol #5 | Sol #6 | Sol #7 | Sol #8 | Sol #9 | Sol #10 | Sol #11 | Sol #12 | Sol #13 | Sol #14 | Sol #15 | Sol #16 | Sol #17 | +|---------------------------------------|---------|--------|--------|--------|--------|--------|--------|--------|--------|---------|---------|---------|---------|---------|---------|---------|---------| +| KI 11: RIC API authorization security | | | X | X | | | X | | | | | | | | | | | +| KI 12: xAppID abuse | | | | | | | | | | | | | | X | | | X | +| KI 13: Malicious Y1 Consumer | | | | | | | | | | | | | | | X | | | +| KI 14: Malicious E2 Node | | | | | | | | | | | | | | | | X | | + +# 8. Recommendations + +The following key issues have been agreed as contributions in O-RAN Threat Model v.03.00: + +- Key issue #1: Malicious xApps deployed on the Near-RT RIC +- Key issue #10: Near-RT RIC APIs authentication +- Key issue #11: Near-RT RIC APIs authorization + +The following solutions have been agreed as contributions in O-RAN Security Requirement Specification v3.0: + +- Solution #1: Secure onboarding and deployment of xApps in Near-RT RIC +- Solution #3: Authentication schema for APIs +- Solution #4: Authorization framework for APIs + +# History + +| Date | Revision | Description | +|------------|----------|--------------------------------------------------------------| +| 22.11.2023 | 5.00.00 | Version 5 of technical report | +| 20.07.2023 | 4.00.00 | Version 4 of technical report | +| 24.02.2023 | 3.00.00 | Version 3 of technical report | +| 08.11.2022 | 2.00 | Version 2 of technical report | +| 24.04.2022 | 2.0.1 | Update of Near-RT RIC architecture and editorial corrections | +| 23.03.2022 | 2.0.0 | First complete version | +| 06.12.2021 | 1.0.0 | First draft / incomplete | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/06fc01b168195375d2ceb906fa336e88_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/06fc01b168195375d2ceb906fa336e88_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..61125dc3f382587a0a6d8f5779f38b92c0574383 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/06fc01b168195375d2ceb906fa336e88_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f5459dfbec84cf38a30bcc6e0fe629e49e9ea99ccfb96a057e09ffcf5cbb2ab0 +size 54268 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/108a643709225785e667648d8b042971_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/108a643709225785e667648d8b042971_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..455ea5ebe63ad68f442f803e90a7677bb8f831bc --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/108a643709225785e667648d8b042971_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fea46b8cff28057528500292f02effc88ac2b209820eeddf4fe5367e1906f30e +size 30871 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/1093a7b69f5a915e7ed2731e41cbbc3d_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/1093a7b69f5a915e7ed2731e41cbbc3d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..477eba2dbe89bc5c61555ec92789c994560330dd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/1093a7b69f5a915e7ed2731e41cbbc3d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8fd7b63c1091cd768763cae31427e25e45aee3bcd7e08f50eb20f42936e67e28 +size 26581 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/1be883946f17b8a13f9fabbbfcfd1df7_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/1be883946f17b8a13f9fabbbfcfd1df7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fea6a38e698ca39d918f40b0403902af66405e26 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/1be883946f17b8a13f9fabbbfcfd1df7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1ab2b9e88d5f2a494b557f8a783a304deabab8d738912ea1c977be585a2362e6 +size 121486 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/2de9c3bf2b11d410793be432ad061699_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/2de9c3bf2b11d410793be432ad061699_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ea355ae0ec3e8e751ec23f7beda162007d91d04 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/2de9c3bf2b11d410793be432ad061699_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:46c054e4c07af079dddb884fccc55ddc6e390559933f75d2e15f3b17f94a528c +size 49071 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/4038ede0326fb728defd5437ff4fc58a_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/4038ede0326fb728defd5437ff4fc58a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ca0e3c282fa8508890db0d6ff006395bdd239a45 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/4038ede0326fb728defd5437ff4fc58a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b9a442ee0524996f79084ee3daa0ca7dcf500774b1c86064b634c7731413bf04 +size 129121 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5461067420bde421ee2402a3e081c6bc_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5461067420bde421ee2402a3e081c6bc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b5fc805c48246a13379bac1afb5676df5d13d29d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5461067420bde421ee2402a3e081c6bc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:852276dfd81559aa0b97e90f33e024e15d1df4f81885dc7518b611333b4657d7 +size 32419 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/564b40b514f14f3ad3259168d4df7ee1_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/564b40b514f14f3ad3259168d4df7ee1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..95e07c1ec0f1cbc648c199909d04e5db3f65b09f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/564b40b514f14f3ad3259168d4df7ee1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:44fed328b6a573ec74adc170612359d24b926984eb4176911518310ae75c09bd +size 69587 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5680c7b2028e4afdf581c566a2bea42c_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5680c7b2028e4afdf581c566a2bea42c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..99f7f433816cb91d1b475ed8b4d24abeda687fe1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5680c7b2028e4afdf581c566a2bea42c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c0da181abaeb1dec1dcc58041392cde5aea3e174d6f8bd5df0ddd38cd75fc825 +size 14180 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..44e4ca1e706fffc218594e75b7fbdfaeee43149d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ba36991bdae993881d357810ae680e8b2718eeb75c0831521a0cdc2d6e038f2 +size 4147 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5de6764bed70ffbd099764b727d380c0_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5de6764bed70ffbd099764b727d380c0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b87e1c75f49eb0946a5bc7e6289033a8bd49d97f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/5de6764bed70ffbd099764b727d380c0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:91dda6456feb896ac543fe4380ae2c4ee61cfd1d25178c9ba85a18d8103bd50d +size 29061 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/66469ac8731c292a214860754a079e62_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/66469ac8731c292a214860754a079e62_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d8332a57a0c707b307338422991ebc68ee0bcebd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/66469ac8731c292a214860754a079e62_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c43e7b2341b20c23b68d60c6580d3670640ff5bb6c107ceadc26b108bb23d580 +size 4147 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/665e2d64c76197ebb7794dff78fe3e03_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/665e2d64c76197ebb7794dff78fe3e03_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..410f545dc9f0bbcc47cd6dc413e9500cdc1eb4af --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/665e2d64c76197ebb7794dff78fe3e03_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9356b272a0b31b58baf283acb18673ab3fa642ce27ee4b8b3f09a4fccf7d43d4 +size 39007 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/6f6aef2063c92dbfd6a4c152b169b7d6_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/6f6aef2063c92dbfd6a4c152b169b7d6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d89ab9ddcd343ee7ae3d98411e61fa67c5bf2126 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/6f6aef2063c92dbfd6a4c152b169b7d6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d840708c6889e72af0e8ad7fa006ee9d2a964e0f246e0399086b2f3f25fc5a18 +size 11322 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/6fb2f15165ea126ec262d2b81d4496cb_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/6fb2f15165ea126ec262d2b81d4496cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aac7a6f9c4b7ced88b9e6320675d373d16686011 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/6fb2f15165ea126ec262d2b81d4496cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c0294a4bc5fb2acf06931ea43bcb9576963a0e12de0e65efb71a4308e797f39a +size 88620 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/81443bac700d5694ea8c09b0faf7a79c_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/81443bac700d5694ea8c09b0faf7a79c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..475442bcf81bfe28b9587ef88a34f602e269e892 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/81443bac700d5694ea8c09b0faf7a79c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd2c4edb6fec9d5724e5edec86f46793146b3b117514ab6b8d86538d756868e6 +size 27538 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/858705c575cfd1586b518419f2d40c08_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/858705c575cfd1586b518419f2d40c08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6881ea11a5ba0f5284f6096d74c45a30864bd4cd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/858705c575cfd1586b518419f2d40c08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:beec328a23056fbc8b86e086ebc58ed81243537c923a49edb38c1da2919500d6 +size 58153 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/93b81487b65064c8f1b8b4fb90b5eef9_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/93b81487b65064c8f1b8b4fb90b5eef9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b95a4033033bbbc117d4aa9eb2d8e79b8f188893 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/93b81487b65064c8f1b8b4fb90b5eef9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b907bdf879730d502c4dd9fa97de370a4c998298ab67879dcedab1988a524c43 +size 4080 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/97e61daa2e2090bb571de418ce468edc_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/97e61daa2e2090bb571de418ce468edc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b78ad8f386db9327efb85068c94591ec29bfcd00 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/97e61daa2e2090bb571de418ce468edc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:edfd71aa47dcb9a5631eeb7505f6f9c32e33fddebaf40875018821f737f9ef3c +size 4038 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/9bd92627fea607c8b9c72ef1d73d487c_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/9bd92627fea607c8b9c72ef1d73d487c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cb4dad1c303c96db09b7cbb74be230b3fa062376 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/9bd92627fea607c8b9c72ef1d73d487c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0adb25325f74da55646ae2a51f0f72d0172126346ce6d72c0347b4c563a26183 +size 64385 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/9dff38abf847e340d6b506ad79122d9b_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/9dff38abf847e340d6b506ad79122d9b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c2e21b41261d859370c7c71a0775731db587b7a0 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/9dff38abf847e340d6b506ad79122d9b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7ff6e9ab2273665dbb26ce9bfc365bf91d17497621a93be0b9bf7aea862fdcb4 +size 27882 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/9e1d1267f6345638c923981b86d4e548_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/9e1d1267f6345638c923981b86d4e548_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7d621299ea7a68b18f55cda63058b87483e70dcc --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/9e1d1267f6345638c923981b86d4e548_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3d3bdfcf722b6cc1d0a6f3ebfa9435404163eed2bd730ce490545435663d41cc +size 30015 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/bb558d2103eceb2abca81003e3e90939_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/bb558d2103eceb2abca81003e3e90939_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e5979f62a30c1785eb12c298666e8979fd26c254 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/bb558d2103eceb2abca81003e3e90939_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2ca31f59518fb2198608325b5f4d2b3510145f88067ed1427669999d157a048d +size 38268 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/bc2e2981598b52002fba062d70e305da_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/bc2e2981598b52002fba062d70e305da_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..43983bf069fb3534e904dfe6265ac6b2e08aab4c --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/bc2e2981598b52002fba062d70e305da_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8066fdc7f85776deb78644e7d9e78ad68ceb5ec1e655b321b01388e3997f7b5c +size 55697 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/bff88cc496db29b8556a47f85f6b3510_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/bff88cc496db29b8556a47f85f6b3510_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bd54e4f9fce1a1b3465b77561ed09bac65e14d6c --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/bff88cc496db29b8556a47f85f6b3510_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8671949a887c12d3dd41c0bf69cde4e851d2b51200517e0d2df77d85c60ef4a7 +size 25870 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/c097f2a742c0fa76286bc71e26a63dae_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/c097f2a742c0fa76286bc71e26a63dae_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e790e99e15d9c3bcf64bbb6b2dddb1c2f5250a55 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/c097f2a742c0fa76286bc71e26a63dae_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c27af6e9d7ca8da7e465a5287788a0f9e4e2a2f92334d507693bc407c8f6501b +size 57555 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/c12067f3658487aaa13073f1ceda04d7_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/c12067f3658487aaa13073f1ceda04d7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eabb1ed71b701ded0304d7b7e1e1e2363c61c040 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/c12067f3658487aaa13073f1ceda04d7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:de32a6fa8b184ae00e1cc40ecee1d6a5e1c682ab4e5183a339bf704e773283c5 +size 36004 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/c483715abe91185948e2fe0108e05c6e_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/c483715abe91185948e2fe0108e05c6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dff839d70f4519fda0c788946375d2d872b7153f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/c483715abe91185948e2fe0108e05c6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5b5d862215c1d4fce03aa8348efe240ff27e312cb20f33d94672f93a44c6fb3a +size 219808 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/d339b67391211d0b08f6180578733d8a_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/d339b67391211d0b08f6180578733d8a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..04519cac8ba5ca382f71ff7b74d549ee80d4fd87 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/d339b67391211d0b08f6180578733d8a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8c63973de8498e493f994d5163b44ba8cba7f0d11715cf967f9ba20e8fd7316e +size 4258 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/d8b655421eaad89c286514e19d2c27f4_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/d8b655421eaad89c286514e19d2c27f4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..701d10ca9dd6634fb4fa05915f5f79d8a0ab51d8 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/d8b655421eaad89c286514e19d2c27f4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:542ca17b6b005a2917a8f6401dec984cc83fa1016b32e11ad1990e4804d1e079 +size 47794 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/daf98618bc0520ce3151fa27e8e714dc_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/daf98618bc0520ce3151fa27e8e714dc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..851053802a96c979c839d3222aa1d9641420ff80 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/daf98618bc0520ce3151fa27e8e714dc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:57f47f175fa7c5bc2233417471295ed5d0289385bd587b9a2314c87da80ce405 +size 24160 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/e139b338bc7401ea21ea3a26e0f8ff4f_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/e139b338bc7401ea21ea3a26e0f8ff4f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a464c34e09a1b6d4ff4fb5f5223ec64df0b23c0f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/e139b338bc7401ea21ea3a26e0f8ff4f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:35ef14f75f51345db18bef2da0f7e92576e2dac072a6954ab176b444685e9f2b +size 29387 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/e9e107abba57a605a98a843bd7277676_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/e9e107abba57a605a98a843bd7277676_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..16741990b6cf8c6c42d05dc1419fa09f1f48d1cf --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/e9e107abba57a605a98a843bd7277676_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7decd5579edb852b280a0e024b9ba72439a3d3d78172d3990c426c1e1ef7b929 +size 39145 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/eed97810b73ce2008906a0918abed322_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/eed97810b73ce2008906a0918abed322_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e9d056186f91071754a1bd66cc5b0f58f9cdcd1d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/eed97810b73ce2008906a0918abed322_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a6feea577002af775f92c1c073ef8e278549447e23549760a568e59d2a4c42d6 +size 4142 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/efa9ac35d7b480da886000414df3283d_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/efa9ac35d7b480da886000414df3283d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e50412afd16a78912b2931a62cda327be7c34449 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/efa9ac35d7b480da886000414df3283d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:402174ee937194c2cdec28f54b933545f8072f9e4128c19fe87757d6a12bcbd7 +size 27583 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/f9899feabd96421800e7d7a3b400406b_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/f9899feabd96421800e7d7a3b400406b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..49b123fbe51327e8aab69503675231896a2386a5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/f9899feabd96421800e7d7a3b400406b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f306e67d7370ce56993b4617d52c51abb444a7fa56c57ca7a57b25f210fd0b15 +size 33442 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/fa49186bb622c095765fd8ddc772729a_img.jpg b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/fa49186bb622c095765fd8ddc772729a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1af4baa9997cb759fd2b6a6708563bc34a058214 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/fa49186bb622c095765fd8ddc772729a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b7de6899a3e71e7d5cb96e3cf5688867518bde70faaa5a1d8d15817d1aa6097 +size 4042 diff --git a/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/raw.md b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..1936d8ac19293bd20edc0c821baa49903ee6475c --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00/raw.md @@ -0,0 +1,1555 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****Study on Security for Fronthaul CUS-Plane** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|----------------------------------------------------------------------------------------------------------------------|----| +| Foreword ..... | 4 | +| Modal verbs terminology ..... | 5 | +| 1. Scope..... | 6 | +| 2. References..... | 7 | +| 2.1 Informative References ..... | 7 | +| 3. Definition of terms, symbols, and abbreviations ..... | 8 | +| 3.1 Terms..... | 8 | +| 3.2 Symbols..... | 8 | +| 3.3 Abbreviations ..... | 8 | +| 4. Security for Fronthaul CUS-Plane ..... | 10 | +| 4.1 Introduction ..... | 10 | +| 4.2 Security for S-Plane ..... | 10 | +| 4.2.1 Introduction ..... | 10 | +| 4.2.2 Key Issues..... | 10 | +| 4.2.3 Solutions ..... | 15 | +| 4.2.4 Evaluation and Conclusions ..... | 17 | +| 4.3 Security for C-Plane ..... | 19 | +| 4.3.1 Key Issues..... | 20 | +| 4.3.2 Solutions ..... | 25 | +| 4.3.3 Evaluation and Conclusions ..... | 25 | +| 4.4 Security for U-Plane..... | 26 | +| 4.4.1 Key Issues..... | 26 | +| 4.4.2 Solutions ..... | 26 | +| 4.4.3 Evaluation and Conclusions ..... | 27 | +| 4.5 Security for Fronthaul Ethernet L1 physical layer interface ..... | 27 | +| 4.5.1 Key Issues..... | 27 | +| 4.5.2 Solutions ..... | 28 | +| 4.6 Security at Fronthaul Layer 2 using MACsec..... | 29 | +| 4.6.1 Introduction ..... | 29 | +| 4.6.2 MACsec Solution Proposals for Fronthaul Security Protection..... | 29 | +| 4.6.3 Deployment consideration for MACsec in Open Fronthaul..... | 36 | +| Annex A (informative): Port-based authentication using 802.1x and 802.1AR Secure Device Identity ..... | 48 | +| Annex B (informative): Deployment consideration for encryption of C Plane messages in an Open Fronthaul network..... | 49 | +| 5. Change history/Change request (history)..... | 51 | + +# LIST OF FIGURES + +| | | +|-------------------------------------------------------------------------------------------------|----| +| Figure 4.2.2.1.1-1 Possible fake ANNOUNCE message attack scenarios in an LLS-C2 deployment..... | 12 | +| Figure 4.2.2.1.1-2 Possible fake ANNOUNCE message attack scenarios in an LLS-C3 deployment..... | 12 | +| Figure 4.2.4.1.1.2-1 Topology Configurations of S-Plane Deployment Scenarios ..... | 19 | +| Figure 4.6.2.1-1 MACsec using EDE-CC solution proposal for fronthaul security protection ..... | 30 | +| Figure 4.6.3.1.1.1-1 MACsec enabled at O-RU and O-DU..... | 32 | +| Figure 4.6.3.1.1.2-1 MACsec enabled at edge Transport Network Elements..... | 32 | +| Figure 4.6.3.1.1.3-1 MACsec enabled at O-RU and TNE2 ..... | 33 | +| Figure 4.6.3.1.1.4-1 MACsec enabled at TNE1 and O-DU ..... | 33 | +| Figure 4.6.3.1.1.5-1 MACsec enabled at O-DU and O-RU ..... | 34 | +| Figure 4.6.3.1.1.6-1 MACsec enabled at O-RU and TNE at the Central Site ..... | 34 | +| Figure 4.6.3.1.1.7-1 MACsec enabled at FHM and O-DU at the Central Site ..... | 34 | +| Figure 4.6.3.1.1.8-1 MACsec enabled at FHM and O-DU at the Central Site ..... | 35 | + +| | | +|-----------------------------------------------------------------------------------------------------------------------------------------|----| +| Figure 4.6.3.1.2.1-1 C-Plane and M-Plane protection based on MACsec in LLS-C1 topology ..... | 35 | +| Figure 4.6.3.1.2.2-1 C-Plane and M-Plane protection based on MACsec in LLS-C2 topology ..... | 36 | +| Figure 4.6.3.1.2.3-1 C-Plane and M-Plane protection based on MACsec in LLS-C3 topology ..... | 36 | +| Figure 4.6.3.1.3.1-1 Shared O-RU Concept [i.5] ..... | 37 | +| Figure 4.6.3.1.3.2.1-1 MACsec enabled at TNE ..... | 38 | +| Figure 4.6.3.1.3.2.2-1 MACsec enabled at the Shared O-RU and the O-DUs ..... | 38 | +| Figure 4.6.3.1.3.2.3-1 MACsec enabled at the Shared O-RU and the O-DUs ..... | 39 | +| Figure 4.6.3.1.3.2.4-1 MACsec enabled at the Shared O-RU and the O-DUs ..... | 39 | +| Figure 4.6.3.1.3.2.5-1 MACsec enabled at TNEs in a non-collocated O-DU scenarios ..... | 40 | +| Figure 4.6.3.1.3.2.6-1 MACsec enabled at Shared O-RU and non collocated O-DUs ..... | 40 | +| Figure 4.6.3.1.3.2.7-1 MACsec enabled at Shared O-RU directly connected to TNEs in non-collocated O-DUs scenario ..... | 41 | +| Figure 4.6.3.1.3.2.8-1 MACsec enabled at the Shared O-RU and the O-DUs for SHARED-ORU-MULTI-OPERATOR Configuration in Hybrid mode. .... | 42 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1. Scope + +The present document studies aspects of securing the C, U and S (CUS) planes on the Open Fronthaul interface between the O-DU and O-RU. + +The study details key issues impacting security, threats emanating from the key issues, and determines potential solutions for securing CUS-Plane traffic on Open Fronthaul. + +# 2. References + +## 2.1 Informative References + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18, or the latest 3GPP release prior to Release 18 that includes that document. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] IETF RFC 7384: “Security Requirements of Time Protocols in Packet Switched Networks +- [i.2] ITU-T G. 8275.1/Y.1369.1 Precision time protocol telecom profile for phase/time synchronization with full timing support from the network +- [i.3] Zero Trust Architecture. NIST Special Publication 800-207. + +- [i.4] IEEE Standard for Local and Metropolitan Area Networks--Port-Based Network Access Control, in IEEE Std 802.1X-2020 (Revision of IEEE Std 802.1X-2010 Incorporating IEEE Std 802.1Xbx-2014 and IEEE Std 802.1Xck-2018), vol., no., pp.1-289, 28 Feb. 2020, doi: 10.1109/IEEESTD.2020.9018454 +- [i.5] O-RAN ALLIANCE TS: “O-RAN Control, User and Synchronization Plane Specification”. +- [i.6] O-RAN ALLIANCE TS: “O-RAN Management Plane Specification”. +- [i.7] O-RAN ALLIANCE TS: “O-RAN White Box Hardware Deployment Scenarios and Base Station Classes” +- [i.8] VOID +- [i.9] IEEE Std 802.1AE-2018, IEEE Standard for Local and metropolitan area networks — Media Access Control (MAC) Security, IEEE, 2018 +- [i.10] IEEE Std 1588 – 2019, IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems, IEEE, 2019 +- [i.11] 3GPP TS 33.511: “Security Assurance Specification (SCAS) for the next generation Node B (gNodeB) network product class” +- [i.12] O-RAN ALLIANCE TS: “Xhaul Packet Switched Architectures and Solutions” +- [i.13] O-RAN ALLIANCE TS: “Synchronization Architecture and Solution Specification.” +- [i.14] O-RAN ALLIANCE TR: “O-RAN Security Threat Modeling and Risk Assessment” +- [i.15] IETF RFC 6407: “The Group Domain of Interpretation” +- [i.16] IETF RFC 4082: “Timed Efficient Stream Loss-Tolerant Authentication” +- [i.17] 3GPP TS 38.323: “NR; Packet Data Convergence Protocol (PDCP)” +- [i.18] ITU-T SG15-LS91: ITU-T Study Group 15 Liaison Statement to O-RAN ALLIANCE +- [i.19] ITU-T G8273.2: Timing characteristics of telecom boundary clocks and telecom time synchronous clocks for use with full timing support from the network +- [i.20] O-RAN ALLIANCE TS: “O-RAN Security Requirements and Controls Specification” +- [i.21] IEEE Std 802E-2020: Privacy Considerations for IEEE 802 Technologies + + + +# 3. Definition of terms, symbols, and abbreviations + +## 3.1 Terms + +**T2a\_min\_cp\_ul:** The minimum O-RU data processing delay between receiving real-time up-link control plane message over the fronthaul interface and receiving the first IQ sample at the antenna. + +**T2a\_max\_cp\_ul:** The earliest allowable time when a real-time up-link control message is received before the corresponding first IQ sample is received at the antenna. + +**Tcp\_adv\_dl:** Corresponding to the time difference (advance) between the reception window for downlink real-time Control messages and reception window for the corresponding IQ data messages. + +**Common Port:** An instance of the MAC Internal Sublayer Service (ISS) used by the SecY to provide transmission and reception of frames for both the controlled and uncontrolled ports. + +**Controlled Port:** The access point used to provide the secure MAC Service to a client of a MAC Security Entity (SecY). + +**MAC Security Entity (SecY):** The entity that operates the MAC Security protocol within a system. + +**Uncontrolled Port:** The access point used to provide the insecure MAC Service to a client of a MAC Security Entity (SecY). + +**Ethernet Data Encryption device (EDE):** A two-port bridge that transmits and receives frames that are assumed to be unprotected to and from one red-side port, and conditionally relays those frames to and from its other black-side port, protecting and verifying frames transmitted and received on the black-side port using MACsec. + +**red-side:** Identifies the Ethernet Data Encryption device (EDE) port that does not use MACsec to protect transmitted frames or verify received frames. + +**black-side:** Identifies the Ethernet Data Encryption device (EDE) port that uses MACsec to protect transmitted frames and verify received frames. + +## 3.2 Symbols + +## 3.3 Abbreviations + +BTCA Best Time Transmitter Clock Algorithm + +CUS-Plane Control, User and Synchronization Plane + +DL Downlink + +DoS Denial of Service + +eCPRI enhanced Common Public Radio Interface + +EDE-CC Ethernet Data Encryption device with red-side recognition of C-TAGs and black-side addition and removal of C-TAGs + +eAxC\_ID eAxC Identifier + +FHM Fronthaul Multiplexer + +GDOI Group Domain of Interpretation + +GM Grandmaster + +ISS MAC Internal Sublayer Service + +IQ In-phase and Quadrature-phase + +MACsec Media Access Control security + +M-Plane Management Plane + +| | | +|---------------|--------------------------------------------------------------------------| +| MitM | Man-in-the-Middle | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| O-CU | O-RAN Control Unit | +| PDCP | Packet Data Convergence Protocol | +| PDV | Packet Delay Variation | +| PRTC | Primary Reference Time Clock | +| PTP | Precision Time Protocol | +| startSymbolId | Start Symbol Identifier | +| SOH | Shared Operator Host | +| SRO | Shared Resource Operator | +| TESLA | Timed Efficient Stream Loss-Tolerant Authentication | +| TNE | Transport Network Equipment (an O-RAN term to denote a transport device) | +| T-BC | Telecom Boundary Clock | +| T-GM | Telecom Grandmaster | +| T-TC | Telecom Transparent Clock | +| T-TSC | Telecom Time Synchronous Clock | +| UL | Uplink | +| VLAN | Virtual Local Area Network | + +# 4. Security for Fronthaul CUS-Plane + +## 4.1 Introduction + +The Open Fronthaul interface links the O-DU with the O-RU with a Lower Layer Functional Split-7-2x based architecture as specified in the O-RAN CUS-Plane specification [i.5]. The present document studies the security aspects of the control plane, user plane and synchronization plane protocols used over the Open Fronthaul interface. + +## 4.2 Security for S-Plane + +### 4.2.1 Introduction + +Within a PTP domain, the grandmaster clock is the primary source of time for clock synchronization using Precision Time Protocol (PTP). + +The IEEE 1588[i.10] standard specifies the Best timeTransmitter Clock Algorithm (BTCA) for electing the network's grandmaster clock in a distributed fashion. The chosen grandmaster clock is responsible for the synchronization of the PTP timeReceiver nodes. + +The BTCA is the basis of PTP functionality. The BTCA specifies how each clock on the network determines the best timeTransmitter clock in its subdomain of clocks, including itself. The BTCA runs on the network continuously and quickly adjusts for changes in network configuration. + +ANNOUNCE messages are used by the BTCA in IEEE 1588[i.10] to build a clock hierarchy and select the grandmaster. A clock which considers itself a better timeTransmitter clock will transmit ANNOUNCE message to invoke a change of timeTransmitter clock. Once the current master recognizes the better clock, the current timeTransmitter stops transmitting SYNC messages and associated clock properties (ANNOUNCE messages in the case of IEEE 1588-2008) and the better clock takes over as timeTransmitter. The BTCA only considers the self-declared quality of clocks and does not take network link quality into consideration. + +RFC 7384 [i.1] has a detailed threat analysis of several key issues and provides a set of security requirements for PTP. In the following clauses we identify and analyze relevant key issues when PTP is used in Open Fronthaul interface for timing and synchronization. + +### 4.2.2 Key Issues + +#### 4.2.2.1 Key Issue #1: Impersonation of a TimeTransmitter clock(Spoofing) within a PTP network with a fake ANNOUNCE message + +##### 4.2.2.1.1 Introduction + +The S-Plane must be protected against an attacker within the PTP network impersonating the timeTransmitter clock's grandmaster Identity value and proposing himself as a grandmaster candidate by sending fake ANNOUNCE messages declaring him to be the best clock in the network. The attacker may be residing either within the attacked network (insider) or on an external network connected to the attacked network. + +![Figure 4.2.2.1.1-1: Possible fake ANNOUNCE message attack scenarios in an LLS-C2 deployment. The diagram shows a Central Site with O-DUs containing PTP Masters, connected to a Switch. A compromised switch (2) can spoof Announce messages. An Impersonating T-GM (1) can send fake Announce messages. Remote Sites contain O-RUs and T-TSCs with additional noise filtering to meet 3GPP. The diagram illustrates the flow of genuine and fake Announce messages through the network.](4038ede0326fb728defd5437ff4fc58a_img.jpg) + +① An external T-GM impersonates and sends fake Announce messages + +② A compromised switch in the fronthaul network can spoof Announce messages + +⚠ Impacted Node + +— O-RAN FrontHaul + +— Air interface + +Figure 4.2.2.1.1-1: Possible fake ANNOUNCE message attack scenarios in an LLS-C2 deployment. The diagram shows a Central Site with O-DUs containing PTP Masters, connected to a Switch. A compromised switch (2) can spoof Announce messages. An Impersonating T-GM (1) can send fake Announce messages. Remote Sites contain O-RUs and T-TSCs with additional noise filtering to meet 3GPP. The diagram illustrates the flow of genuine and fake Announce messages through the network. + +**Figure 4.2.2.1.1-1 Possible fake ANNOUNCE message attack scenarios in an LLS-C2 deployment.** + +![Figure 4.2.2.1.1-2: Possible fake ANNOUNCE message attack scenarios in an LLS-C3 deployment. The diagram shows a Central Site with O-DUs containing T-TSCs, connected to a Switch. A compromised switch (2) can spoof Announce messages. An Impersonating T-GM (1) can send fake Announce messages. Remote Sites contain O-RUs and T-TSCs with additional noise filtering to meet 3GPP. The diagram illustrates the flow of genuine and fake Announce messages through the network.](1be883946f17b8a13f9fabbbfcfd1df7_img.jpg) + +① An external T-GM impersonates and sends fake Announce messages + +② A compromised switch in the fronthaul network can spoof Announce messages + +⚠ Impacted Node + +— O-RAN FrontHaul + +— Air interface + +Figure 4.2.2.1.1-2: Possible fake ANNOUNCE message attack scenarios in an LLS-C3 deployment. The diagram shows a Central Site with O-DUs containing T-TSCs, connected to a Switch. A compromised switch (2) can spoof Announce messages. An Impersonating T-GM (1) can send fake Announce messages. Remote Sites contain O-RUs and T-TSCs with additional noise filtering to meet 3GPP. The diagram illustrates the flow of genuine and fake Announce messages through the network. + +**Figure 4.2.2.1.1-2 Possible fake ANNOUNCE message attack scenarios in an LLS-C3 deployment.** + +Figures 4.2.2.1.1-1 and 4.2.2.1.1-2 above depict possible fake ANNOUNCE message scenarios in an Open Fronthaul LLS-C2 and LLS-C3 deployments, respectively. In both deployments two possible scenarios are indicated. Scenario 1: + +An attacker can possibly gain access to the network and inject the fake ANNOUNCE messages. Scenario 2: An attacker can gain control of a network element and inject the fake ANNOUNCE messages. + +##### 4.2.2.1.2 Threats + +This attack results in a situation where the attacker clock becomes a GM, PTP is operational, all clocks are synchronized, but the malicious GM provides intentionally inaccurate timing information. + +This degradation in the accuracy of time may cause DoS to applications on all the O-RUs, and O-DUs that rely on accurate time, potentially bringing down the cell. + +A cell outage caused by misaligned time, may further impact performance in connected neighboring cells. + +##### 4.2.2.1.3 Risk analysis + +Impact: + +- High - as it can bring down all the cells that the impacted O-RUs are serving. + +Likelihood: + +- High - Since ANNOUNCE messages can be seen publicly (as it is sent in clear text), unless link is confidentiality protected, it becomes easy for an attacker to spoof an existing timeTransmitter clock and use spoofed identity to declare itself as the timeTransmitter. This could be a bigger risk for a centralized timing network for the Open Fronthaul. + +##### 4.2.2.1.4 Potential Security Requirements + +[REQ-1] The security mechanism for PTP shall support authentication of ANNOUNCE messages that allows timeReceivers to authenticate the identity of the timeTransmitters. The authentication mechanism shall also verify that the sender is authorized to be a timeTransmitter. + +[REQ-2] The security mechanism for PTP shall provide a means to prevent spoofing of timeTransmitter clocks. + +[REQ-3] The security mechanism for PTP shall provide integrity protection for ANNOUNCE messages + +[REQ-4] The security mechanism for PTP shall provide replay protection for ANNOUNCE messages, for e.g. using a monotonically increasing packet sequence number. + +[REQ-5] The security mechanism for PTP shall harden the clock nodes as per 3GPP TS 33.511 SCAS for gNB [i.11]. + +[REQ-6] The system may provide confidentiality protection for ANNOUNCE messages. + +#### 4.2.2.2 Key Issue #2: A Rogue PTP Instance wanting to be a Grandmaster + +##### 4.2.2.2.1 Introduction + +The S-Plane must be protected against an attacker proposing himself as a grandmaster candidate by sending manipulated/malicious ANNOUNCE messages declaring him to be the best clock in the network. The attacker causes other nodes in the network to believe it is a legitimate timeTransmitter. The attacker has access to the PTP network and could launch this attack by either modification of in-flight PTP-stack-defined packets or injecting fake ANNOUNCE messages to the PTP network. It is assumed that the attacker has physical access to a segment of the network or has gained control of one of the nodes in the network. + +##### 4.2.2.2.2 Threats + +This attack results in a situation where the PTP is operational, but timeReceivers are being provided intentionally inaccurate timing information. + +This degradation in the accuracy of time or false time may cause DoS to applications on all the O-RUs and O-DUs that rely on accurate time, potentially bringing down multiple cells or a part of the network if affecting O-DUs. + +A cell outage caused by misaligned time, may further impact performance in connected neighboring cells. + +##### 4.2.2.2.3 Risk analysis + +Impact: High + +Likelihood: Medium + +Since PTP-stack messages can be seen publicly, it becomes easy for an attacker to spoof an existing timeTransmitter clock and use spoofed identity to declare itself as the timeTransmitter or directly interfere with data in PTP messages to reflect an incorrect time. + +##### 4.2.2.2.4 Potential Security Requirements + +Same requirements indicated in 4.2.2.1.4 + +#### 4.2.2.3 Key Issue #3: DoS attack against a timeTransmitter clock + +##### 4.2.2.3.1 Introduction + +The S-Plane must be protected against the denial of service (DoS) attack towards a timeTransmitter clock of the timing network used by the Open Fronthaul to maintain the availability and accuracy of the timeTransmitter clock. An attacker can attack a timeTransmitter clock by sending an excessive number of time protocol packets, or can potentially record the packets and replay them at a later time or impersonate a legitimate clock, a timeReceiver, or an intermediate clock, by sending malicious messages to the timeTransmitter, thus degrading the victim's performance. + +The attacker may be residing either within the attacked network (insider) or on an external network connected to the attacked network. + +##### 4.2.2.3.2 Threats + +This attack results in a situation where the clock service is interrupted completely, or the timing protocol is operational, but timeReceivers are being provided inaccurate timing information due the degraded performance of the timeTransmitter clock, or cause the attacked clock to go back in time[i.1]. + +This clock service disruption or degradation in the accuracy of time may cause DoS to applications on all the O-RUs and O-DUs that rely on accurate time, potentially bringing down the cell or larger portion of mobile network. + +A cell outage caused by misaligned time, may further impact performance in connected neighboring cells. + +##### 4.2.2.3.3 Risk analysis + +Impact: High, especially for PTP network with telecom profile for time synchronization with full timing support from the network [i.2]. + +Likelihood: Medium + +Since PTP messages are in clear text, unless link is confidentiality protected and there is no mandate for a timeTransmitter to authenticate its timeReceivers, it becomes easy for an attacker to conduct the network reconnaissance, map out the entire timing network topology and launch the DoS attack against the timeTransmitter clock. + +##### 4.2.2.3.4 Potential Security Requirements + +[REQ-1] The security mechanism for PTP could provide a means for a timeTransmitter clock to authenticate its timeReceivers and verify that the sender of a protocol packet is authorized to send a packet of this type. + +NOTE: This would require updates to IEEE 1588 specifications. + +[REQ-2] The security mechanism for PTP could provide a means (e.g. random session keys for authentication) for protection against PTP replay attack. + +NOTE: This would require updates to IEEE 1588 specifications. + +[REQ-3] A security mechanism that is external to PTP such as MACsec at layer 2 may provide link layer based security enabling authentication, integrity, and confidentiality (optional, because of the cadence of PTP protocol itself) for the PTP messages, and thus effectively hiding the timing network topology and preventing DoS attack against the timeTransmitter clock or other nodes. + +#### 4.2.2.4 Key Issue #4: Selective interception and removal of PTP timing packets + +##### 4.2.2.4.1 Introduction + +An attacker can position himself in such way that allows him to intercept and remove valid synchronization packets. This leads to clock synchronization errors of all clocks downstream or makes them go into free-running mode. + +Attacks may be launched close to the GM by tapping the egress line and ingress line of an active GM clock. This impacts a larger set of timeReceivers who depend on this GM for timing synchronization. + +Attacks may also target one or more timeReceivers. This is done by tapping the ingress or egress line of a particular timeReceiver (s). The impact is confined to the targeted timeReceivers, but is also applicable to T-BC where impact is larger the higher up in hierarchy the attack is. + +Alternatively, a MiTM attacker can reside in an intermediate node such as T-TCs, T-TC routers and switches to launch this attack. Then the attacker has physical access to a node of the PTP n/w or has gained full control of one device in the network. This requires additional capability to tap the h/w where PTP timing is implemented, if T-BC or T-TC is implemented in SW, compromise the integrity of the service by remote code execution, or influence the local time in the T-TC or T-BC by affecting the T\_OC in the host device of network element. + +##### 4.2.2.4.2 Threats + +Selective interception and removal or delay can impact timing packets and cause clock degradation in attacked nodes. Removing all packets or random packets may push the clocks in attacked nodes into free running mode or by careful manipulation adjust time and frequency of O-DU and O-RU impacting network wide operation of cellular service. + +This attack results in a situation where the time protocol is operational, but T-TSC in O-DU and O-RU timeReceivers are being provided intentionally inaccurate timing information. + +This degradation in the accuracy of time may cause DoS to applications on all the O-RUs that rely on accurate time, potentially bringing down the cell or O-DU impacting multiple O-RUs. Similar if affecting T-BC or T-TC. + +A cell outage caused by misaligned time, may further impact performance in connected neighboring cells. + +##### 4.2.2.4.3 Risk Analysis + +Impact: High + +Likelihood: Low. + +Attacker either has to tap into a line or has complete control of an intermediate node to launch this attack. In an operator network, it is expected that physical assets including transmission lines are adequately protected from tampering and sabotage. + +##### 4.2.2.4.4 Potential Security Requirements + +There shall be a security mechanism that provides protection against MitM attacks that degrade the clock accuracy due to PTP timing packet removal or packet delay attacks. This type of attack would be mitigated by deploying confidentiality protection on all messages as an attacker would need to delay all packets and not just selectively Sync and delay request, increasing the complexity. As all packets are obfuscated it would not be possible to selectively drop PTP related ones. + +NOTE: Cryptographic security protocols cannot protect against packet drops. One suggested mechanism is to have a secure architecture that provides redundant paths between GM and timeReceivers, which then allows the operator to switch to another path between GM and timeReceivers. + +#### 4.2.2.5 Key Issue #5: Packet delay manipulation attack + +##### 4.2.2.5.1 Introduction + +IEEE 1588 requires symmetric delays between GM and timeReceivers. In packet delay manipulation attacks, the attacker is positioned such a way that allows him to delay the transmission of legitimate time synchronization protocol packets to the intended destination. + +An attacker launches this attack by either tapping the transmission network or by taking control of an intermediate nodes such as routers, switches and T-TCs. + +##### 4.2.2.5.2 Threats + +This attack results in a situation where the time protocol is operational, but timeReceivers are being provided intentionally inaccurate timing information. + +This degradation in the accuracy of time may cause DoS to applications on all the O-RUs, O-DU and T-TSC of the intermediate T-TC or T-BC that rely on accurate time, potentially bringing down the cell or partial or entire mobile network depending on where the attacker is. + +A cell outage caused by misaligned time, may further impact performance in connected neighboring cells. + +##### 4.2.2.5.3 Risk Analysis + +Impact: High + +Likelihood: Low. + +Attacker either has to tap into a line or has complete control of an intermediate node to launch this attack. In an operator network, it is expected that physical assets including transmission lines are adequately protected from tampering and sabotage. + +##### 4.2.2.5.4 Potential Security Requirements + +Same as 4.2.2.4.4. + +### 4.2.3 Solutions + +#### 4.2.3.1 Solution #1: Hardening of Fronthaul infrastructure + +Implementing protection for S-Plane PTP messages is challenging for the following reasons: + +- Need hardware support on new devices for timestamping and support for it in existing devices. Vendors would require at least 2yrs to implement this feature in their products. Until then their products will not be O-RAN standards compliant. +- Any e2e security between timeTransmitter and timeReceiver, will disallow use of transparent clocks in the network as it needs to update the correction field. +- Also, this means legacy equipment can never be "O-RAN Compliant". For WG4, this would be considered a non-backward-compatible change to the FH interface. + +It is therefore infeasible to realize the solution with the present state of hardware availability in the market. + +Security for S-Plane PTP messages would be implicitly achieved by hardening of all the network elements in the Open Fronthaul network including O-RU, intermediary switches, and physically securing all the underlying infrastructure including transmission wires etc. + +#### 4.2.3.2 Solution #2: Using Layer-2 MACsec for protecting S-Plane messages + +MACsec [i.9] could be a possible solution for protection of S-Plane messages. When MACsec is used, PTP messages are protected at Layer 2. + +Evaluation of the impact of using MACsec on S-Plane messages are discussed in clause 4.2.4.1. + +#### 4.2.3.3 Solution #3: Authentication and Authorization based on 802.1X Port Based Access Control + +In order to prevent an attacker masquerading as a grandmaster or manipulating PTP to degrade synchronization, it is essential to implement authentication and authorization for PTP nodes. + +The two most common deployment models for O-DU in O-RAN are: + +- O-DU at the cell site deployment model: the O-DU is collocated with the O-RU with a direct connection between the two (LLS-C1) through a cell site gateway router. +- O-DU at the Data Centre deployment model: the O-DU is at a Data Centre. The O-RUs at the cell site connect to the O-DU via a direct connection between O-RU and O-DU (LLS-C1) or intermediary Ethernet switches (LLS-C2 or LLS-C3). + +IEEE 802.1X-2020 Port-based Network Access Control [i.4] provides the means to control network access in point-to-point LAN segments within the Open Fronthaul network. It provides a solution for the authentication and authorization of S-Plane PTP nodes within Open Fronthaul point-to-point LAN segments. + +Clause 4.5.2.1 provides an e2e solution of protecting the Open FH Interface using Port Based Access Control. + +#### 4.2.3.4 Solution #4: Providing redundancy in Open Fronthaul synchronization architecture + +In order to protect the S-Plane against MitM attacks that degrade the clock accuracy due to packet delay attacks or selective interception and removal attacks [i.1] it is essential to have redundancy and resiliency in the Open Fronthaul Synchronization architecture. + +The following architectural recommendations for security controls build S-Plane redundancy into the Open Fronthaul for increased robustness against security breaches. + +- The Open Fronthaul Synchronization architecture supports simultaneous Grandmasters. +- The Open Fronthaul Synchronization architecture supports the assignment of GMs to physically separated PTP ports. Multiple timeTransmitters could be connected to offer topology resilience. + +O-RAN Synchronization Architecture and Solution Specification [i.13] Clause 8.2.4 provides additional details on redundancy for the Open Fronthaul Synchronization architecture. + +#### 4.2.3.5 Solution #5: Using the PTP integrated security mechanism + +##### 4.2.3.5.1 General + +To ensure the security of the S-plane in the O-RAN fronthaul, the authentication mechanism defined in IEEE 1588-2019 [i.10], clause 16.14 is considered. This involves using the AUTHENTICATION TLV to provide source authentication, message integrity, and replay attack protection for PTP Announce messages within a PTP domain. + +For event messages, care must be taken to make sure that time stamping accuracy is not decreased when updating the AUTHENTICATION TLV. This can be especially demanding for 1-step clocks. Another aspect to consider is that PTP messages are sent in clear text making them at risk of man-in-the-middle attacks delaying PTP event messages in a manner that impacts the timing accuracy. It should also be noted that the PTP integrated security mechanism only addresses PTP security, not any other L2 protocol. This will impact the security posture if the goal is to be consistent with a zero trust architecture (ZTA). + +##### 4.2.3.5.2 Key Management Scheme for the PTP integrated security mechanism + +For a security key management scheme, the following options can be considered: + +- GDOI: GDOI (“Group Domain of Interpretation,” [i.15]) is a group key management protocol that provides secure distribution and management of cryptographic keys to multiple entities in a group. It enables efficient and scalable authentication and encryption for large networks. +- TESLA: TESLA (“Timed Efficient Stream Loss-Tolerant Authentication,” [i.16]) is a one-way hash chain-based authentication mechanism that provides message authentication, allowing all message receivers to check the integrity and authenticate the source of each message in multicast or broadcast data streams. +- Direct configuration: Direct configuration involves manually configuring the security keys on each network element. + +### 4.2.4 Evaluation and Conclusions + +#### 4.2.4.1 Solution #2: Using Layer-2 MACsec for protecting S-Plane messages + +##### 4.2.4.1.1 Evaluation + +###### 4.2.4.1.1.1 Implementation challenges in PTP over MACsec + +MACsec [i.9] provides security using end-to-end and hop-by-hop modes on Ethernet links. ITU-T Study Group 15 lists the use of MACsec as an option to provide confidentiality and integrity protection for PTP and has shared this list with the O-RAN ALLIANCE via a Liaison Statement ITU-T SG15-LS91 [i.18]. However, PTP over MACsec implementation has its challenge related to timestamping of PTP event messages. There are two types of clock implementation in PTP – one-step clock and two-step clock. Each of these has its challenges in implementing PTP over MACsec. Special care needs to be taken when designing the timestamping mechanism to make sure that PTP Event messages are timestamped without impacting time accuracy. This can be more demanding for 1-step clocks than 2-step clocks. A benefit of using MACsec is that all ethernet frames can be encrypted to provide confidentiality and integrity protection, decreasing risk of MitM attacks. + +###### 4.2.4.1.1.1.1 Implementation of Sync message transmission in one step clock + +In one step clock implementation, egress timestamp of Sync message is inserted in Sync message itself. There are at least three possible ways to implement timestamping of PTP Sync messages in the egress (TimeTransmitter) port. + +1. Adjusting the ethernet frame including update of MACsec after timestamping without affecting the needed time accuracy +2. Implement the ethernet port so there is a deterministic delay from the timestamping point to the physical connector +3. Pick a timestamp corresponding to a future time and schedule the ethernet frame on the ethernet port when that future time occurs + +Transmission of PTP delay request messages needs to be treated similar as sync messages with the exception that there is no need to insert the timestamp into the packet. + +###### 4.2.4.1.1.1.2 Implementation challenge in Sync message transmission in two-step clock + +In two step clock, T1 timestamp is carried in a subsequent Follow Up message. Since Sync message does not carry T1 timestamp, this means that no modification of the message after timestamping is needed. This means that both Sync and Delay request messages can be timestamped and handled in the same fashion. + +###### 4.2.4.1.1.1.3 Implementation challenge in PTP event message reception + +At reception of PTP messages inside a MACsec tunnel there is a need to do timestamping before decryption. This means that all received messages needs to be timestamped. The timestamp then follows the received messages and once it is decrypted and found to be a PTP event message the timestamp is used. + +Another method is to implement the ethernet port so that there is a deterministic delay from the physical connector to the timestamping point. + +###### 4.2.4.1.1.2 Deployment challenges in PTP over MACsec + +There are four S-Plane deployment scenarios for the O-RAN Open Fronthaul described in [i.5] and illustrated in the figure below. + +![Figure 4.2.4.1.1.2-1 Topology Configurations of S-Plane Deployment Scenarios. The figure shows four configurations: LLS-C1, LLS-C2, LLS-C3, and LLS-C4. LLS-C1 shows a direct PTP/PLFS path between a central site (O-DU, PLFS+PTP master) and a remote site (O-RU, T-TSC). LLS-C2 shows a central site (O-DU, PLFS+PTP master) connected to one or more switches in a fabric topology, which then connect to remote sites (O-RU, T-TSC). LLS-C3 shows a central site (O-DU, T-TSC) connected to a network of switches containing a PRTC/T-GM, which then connect to remote sites (O-RU, T-TSC). LLS-C4 shows a central site (O-DU) connected to a remote site (O-RU) via a fronthaul link, with no PTP/PLFS support required.](6fb2f15165ea126ec262d2b81d4496cb_img.jpg) + +**Configuration of LLS-C1** + +**Configuration of LLS-C2** + +**Configuration of LLS-C3** + +**Configuration of LLS-C4** + +Figure 4.2.4.1.1.2-1 Topology Configurations of S-Plane Deployment Scenarios. The figure shows four configurations: LLS-C1, LLS-C2, LLS-C3, and LLS-C4. LLS-C1 shows a direct PTP/PLFS path between a central site (O-DU, PLFS+PTP master) and a remote site (O-RU, T-TSC). LLS-C2 shows a central site (O-DU, PLFS+PTP master) connected to one or more switches in a fabric topology, which then connect to remote sites (O-RU, T-TSC). LLS-C3 shows a central site (O-DU, T-TSC) connected to a network of switches containing a PRTC/T-GM, which then connect to remote sites (O-RU, T-TSC). LLS-C4 shows a central site (O-DU) connected to a remote site (O-RU) via a fronthaul link, with no PTP/PLFS support required. + +**Figure 4.2.4.1.1.2-1 Topology Configurations of S-Plane Deployment Scenarios** + +- Configuration LLS-C1 is based on point-to-point connection between O-DU and O-RU using network timing option. As shown above, it is the simplest topology for network timing option, where O-DU directly synchronizes O-RU. +- Configuration LLS-C2 is similar to LLS-C1 with O-DU acting as grandmaster to distribute network timing toward O-RU. One or more Ethernet switches are allowed between the central site (hosting O-DUs) and the remote sites (hosting O- RUs). All the switches in the synchronization path will need to support PTP with hop-by-hop MACsec for security protection while maintaining the needed ITU-T G8273.2 Class to meet end-to-end synchronization performance. +- Configuration LLS-C3 is similar to LLS-C2 except frequency and time distribution is made by the fronthaul network itself (not by the O-DU). That means that one or more PRTC/T-GM are implemented in the fronthaul network to distribute network timing toward O-DU and O-RU. One or more Ethernet switches are allowed between the central site (hosting O-DUs) and the remote sites (hosting O-RUs). Also, similar to LLS-C2, all the switches in the synchronization path will need to support PTP with hop-by-hop MACsec for security protection while maintaining the needed ITU-T G8273.2 [i.19] Class to meet end-to-end synchronization performance. +- Under configuration of LLS-C4, local or remote PRTC time source option is allowed at O-RU and O-DU respectively, there is no PTP based S-Plane required for the Fronthaul. Therefore, no PTP protection scheme is needed. + +##### 4.2.4.1.2 Conclusion + +MACsec is being considered to provide confidentiality and integrity protection on the Open Fronthaul S-Plane. Hop-by-hop MACsec has additional benefits protecting all traffic on the LAN segment, not only S-Plane. + +#### 4.2.4.2 Solution #3: Authentication and Authorization based on 802.1X Port Based Access Control + +##### 4.2.4.2.1 Evaluation + +The S-Plane should support authentication and authorization of PTP nodes that communicate with other PTP nodes within Configuration LLS-C1, Configuration LLS-C2, or Configuration LLS-C3. + +This ensures least privilege access to the S-Plane by ensuring the authenticity of PTP nodes communicating over the Open Fronthaul network. + +##### 4.2.4.2.2 Conclusion + +IEEE 802.1X Port-based Network Access Control [i.4] restricts network access to authorized PTP nodes. + +#### 4.2.4.3 Solution #4: Providing redundancy in Open Fronthaul Synchronization architecture + +##### 4.2.4.3.1 Evaluation + +This clause addresses the Key Issue#4 as defined in clause 4.2.2.4 + +An architectural recommendation to S-plane security is proposed based on redundancy and resiliency in the Open Fronthaul Synchronization architecture. + +##### 4.2.4.3.2 Conclusion + +Implementing redundancy and resiliency synchronization architecture provides timing/sync reliability by avoiding single point failure. + +## 4.3 Security for C-Plane + +The O-RAN interface is divided into C-Plane and U-Plane parts. + +The C-Plane must be available in order to process the corresponding U-Plane packets. + +The main purpose of these messages is to transmit **data-associated control information** required for processing of user data (e.g., scheduling and beamforming commands). + +To support coordination of C-Plane and U-Plane timing, the O-RAN interface specifies that C-Plane messages must arrive at the O-RU some amount of time in advance (Tcp\_adv\_dl) of the latest possible time the first corresponding U-Plane messages may arrive. + +According to clause 5.2.1 of C-Plane Transport[i.5] either **eCPRI** or **IEEE 1914.3** is used as an encapsulation mechanism for the control-plane messages. + +C-Plane messages are encapsulated using a two-layered header approach. + +The first layer consists of an **eCPRI common header** or **IEEE 1914.3 common header**, including corresponding fields used to indicate the message type, while the second layer is an **application layer** including necessary fields for control and synchronization. + +![](6f6aef2063c92dbfd6a4c152b169b7d6_img.jpg) + +| | +|----------------| +| eCPRI / RoE | +| UDP (optional) | +| IP (optional) | +| Eth L2 + VLAN | +| Eth L1 | + +The control information will not be transmitted via the eCPRI specific protocol. + +This information can use protocols (e.g. TCP) over the IP protocol but **any other solution is not precluded**. + +The control information flow will be considered as real-time control and utilize a small part of the total bandwidth between O-DU and O-RU entities. + +Loss of a C-Plane packet is serious, with the possibility of impacting an entire slot's worth of data. -> A broader impact is also possible with C-Plane packet loss: **if downloaded beamforming weights, beamforming attributes, or channel information is lost** then a beamId may be incorrectly associated with an "old" set of beamforming weights thereby possibly impacting multiple slots. (packet loss can be detected via the sequence number so a recovery action may be taken to re-send messages), but no such action has been mandated yet in [i.5]). + +Editor's Note: It is FFS how the sequence number recovery would work in case of injection of higher values. + +### 4.3.1 Key Issues + +#### 4.3.1.1 Key Issue #1: Spoofing of DL C-Plane messages + +##### 4.3.1.1.1 Introduction + +As described in [i.5], clause 4.4.3, a DL C-Plane message describing multiple symbols must arrive at O-RU at least $T_{cp\_adv\_dl}$ before the end of DL U-Plane receive window for symbol $startSymbolId$ (the earliest symbol described by the message). + +##### 4.3.1.1.2 Threats + +The lack of authentication could allow an adversary to inject its own DL C-Plane messages that falsely claim to be from the associated O-DU. + +As a result, it would block the O-RU from processing the corresponding U-Plane packets, leading to temporary DoS. (dropping the entire DL C-Plane messages would achieve same goal) + +##### 4.3.1.1.3 Risk analysis + +Impact: High + +Likelihood: Medium + +An attacker needs physical access to the network transporting C-Plane messages. + +##### 4.3.1.1.4 Potential Security Requirements + +[REQ-1] The security mechanism for C-Plane shall support authentication of
to allow O-RU to authenticate the O-DU (transport-based endpoint identifiers). The authentication mechanism shall also verify that the O-DU is authorized to serve the O-RU. + +#### 4.3.1.2 Key Issue #2: Spoofing of UL C-plane messages + +##### 4.3.1.2.1 Introduction + +A UL C-Plane message describing multiple symbols must arrive at O-RU at least $t_{2a\_min\_cp\_ul}$ before the earliest air interface UL signal sample of symbol $startSymbolId$ (the earliest symbol described by the message) arrives at O-RU antenna. UL C-Plane messages from O-RU to O-DU are only defined in case of LAA operations. (otherwise, there should be no C-Plane messages originated by the O-RU). + +##### 4.3.1.2.2 Threats + +The lack of authentication could allow an adversary to inject its own UL C-Plane messages that falsely claim to be from the associated O-DU. + +As a result, temporarily limited cell performance (or even DoS) on cells served by the O-RU and in addition a consequential threat to all O-RUs parented to that O-DU might exist. (dropping the entire UL C-Plane messages would achieve same goal) + +##### 4.3.1.2.3 Risk analysis + +Impact: High + +Likelihood: Medium + +An attacker needs physical access to the network transporting C-Plane messages. + +##### 4.3.1.2.4 Potential Security Requirements + +[REQ-1] The security mechanism for C-Plane shall support authentication of
    to allow O-RU to authenticate the O-DU (transport-based endpoint identifiers). The authentication mechanism shall also verify that the O-DU is authorized to serve the O-RU as well as that the O-RU is authorized to communicate to the O-DU. + +#### 4.3.1.3 Key Issue #3: Loss of Availability of Cell (Sleeping Cell) caused by C-Plane message tampering. + +##### 4.3.1.3.1 Introduction + +In mobile communication a sleeping cell is an unlocked cell that is transmitting on the broadcast channel, has no alarms active yet is unable to setup calls. + +##### 4.3.1.3.2 Threats + +An attacker may tamper DL C-Plane messages to exploit possible vulnerabilities in the C-Plane protocol or C-Plane endpoint implementation to cause an active cell to become a sleeping cell. As a result, this would result in cell unavailability, leading temporarily to DoS. + +##### 4.3.1.3.3 Risk analysis + +Impact: High + +Likelihood: Medium; An attacker needs physical access to the network transporting C-Plane messages. Vulnerabilities in the C-Plane protocol or C-Plane endpoint implementation may exist. + +##### 4.3.1.3.4 Potential Security Requirements + +[REQ-1] Authenticated integrity protection should protect C-Plane data flows through the fronthaul network, as that would allow the O-RU to detect altered messages and prevent their execution. + +Further security measures include: + +- **Regular Patching and Updates:** Keeping the C-Plane related software up to date by regularly applying security patches and updates provided by the vendor. This ensures that known vulnerabilities are fixed, reducing the risk of exploitation. +- **Network Segmentation:** Implementing network segmentation to isolate critical systems from the rest of the network. This limits the potential impact of a C-Plane protocol stack vulnerability by containing the attack within a smaller network segment. +- **Intrusion Detection and Prevention Systems (IDPS):** Deploying IDPS solutions to monitor network traffic and detect potential IP stack attacks in real-time. These systems can identify and block malicious activities, providing an additional layer of defense against exploitation. +- **Implementing a ZTA with MACsec e2e or hop-by-hop protecting the C-Plane.** + +#### 4.3.1.4 Key Issue #4: C-Plane volumetric DoS attacks. + +##### 4.3.1.4.1 Introduction + +Attackers may overwhelm a target system's network bandwidth or computing resources by flooding it with a massive volume of traffic. This is called a volumetric Denial-of-Service (DoS) attack. + +##### 4.3.1.4.2 Threats + +Threats of attackers mounting volumetric DoS attacks include + +- **Bandwidth Exhaustion:** Attackers generate a large amount of traffic directed at the target's network interfaces, consuming all available bandwidth. This can result in legitimate data flows being unable to access the services or resources provided by the target system. +- **Resource Consumption:** Volumetric DoS attacks consume significant computing resources of the target, such as CPU, memory, or network connections. This can lead to degraded performance or even a complete system failure, rendering the target inaccessible. +- **Network Congestion:** The high volume of malicious traffic overwhelms the network infrastructure between the attacker and the target, causing congestion and potentially impacting other network services or users. + +##### 4.3.1.4.3 Risk analysis + +Impact: High + +Likelihood: Medium; An attacker needs physical access to the network transporting C-Plane messages and sufficient resources to actually overwhelm the network/target. + +##### 4.3.1.4.4 Potential Security Requirements + +[REQ-1] Authenticated integrity protection and anti-replay protection should allow the target to detect all legitimate messages with relatively low processing overhead. This would allow the target to defend against resource consumption. + +[REQ-2] As a further security measure Traffic Monitoring and Analysis can be employed, i.e. implementing network traffic monitoring and analysis tools to detect and identify abnormal traffic patterns that may indicate a volumetric DoS attack. Solutions like intrusion detection and prevention systems (IDPS) or traffic anomaly detection systems can assist in real-time detection. Physical security and system Log monitoring can also help mitigate this type of an attack. + +#### 4.3.1.5 Key Issue #5: Intentionally causing delay or dropping of C-Plane messages carrying scheduling and beam forming commands + +##### 4.3.1.5.1 Introduction + +UL C-Plane message describing multiple symbols must arrive at O-RU at least $t_{2a\_min\_cp\_ul}$ before the earliest air interface UL signal sample of symbol $startSymbolId$ (the earliest symbol described by the message) arrives at O-RU antenna. + +DL C-Plane message describing multiple symbols must arrive at O-RU at least $T_{cp\_adv\_dl}$ before the end of DL U-Plane receive window for symbol $startSymbolId$ (the earliest symbol described by the message). + +##### 4.3.1.5.2 Threats + +Any delay in the arrival of these messages would cause the O-RU to drop/discard UL C-Plane and DL C-Plane traffic from O-DU and the UE causing a denial of service for the impacted UEs. + +##### 4.3.1.5.3 Risk analysis + +Impact: Medium + +Likelihood: Medium + +An adversary or insider would need to have direct (physical) access to the network path between O-DU and O-RU, e.g. to routers and switches, to employ active monitoring techniques to intercept messages. The adversary can then store and forward the intercepted messages, inducing an intentional delay in the arrival of the message at the O-RU. This would cause the O-RU to drop /discard UL C-Plane and DL C-Plane traffic resulting in a DoS attack on the O-RU. + +##### 4.3.1.5.4 Potential Security Requirements + +None + +#### 4.3.1.6 Key Issue #6: Targeted Reconnaissance attack on a user + +##### 4.3.1.6.1 Introduction + +When the flow indicator (eAxCID) is carried in clear text, an attacker can look at this information to target a certain user in a certain physical location. User Identity is not revealed, but there could be scenarios where an attack can be pre-meditated on a well-known user based on the available location of the user at a certain point in time. + +Combined with a correlation attack on backhaul data may reveal more about the individual or organization, see [i.21] + +##### 4.3.1.6.2 Threats + +This attack can be used to launch a reconnaissance attack on the targeted user based on the flow indicator and traffic patterns. + +##### 4.3.1.6.3 Risk analysis + +Impact: Medium + +Likelihood: Low + +Malicious actors can engage in passively monitoring the beamforming information for reconnaissance purposes. However, conducting a successful reconnaissance attack of this nature requires prior knowledge of the targeted user's movement patterns and required infrastructure. The post-processing needed to extract useful user-specific information is a complex and exhaustive process. + +##### 4.3.1.6.4 Potential Security Requirements + +[REQ-1] The C-Plane data should be encrypted to prevent an insider from intercepting or gathering sensitive information on a targeted user. + +This requirement applies to deployment scenarios where the O-RU and O-DU are in two separate locations connected via a switched fronthaul network. Refer to Annex B for additional information. + +NOTE: In scenarios where the O-RU and O-DU are collocated and confined within the secure perimeter of a cell-site location, the need for encryption of C-Plane messages is reduced. + +Physical security of a cell site is ensured by security measures like restricted access to the site which means only authorized personnel should be allowed entry and access may be controlled by keycards, biometrics, or other secure mechanisms. Additionally, surveillance systems, and secure enclosures for the O-RAN components, regular audit and inspections are other measures that ensure perimeter security of a cell site. + +#### 4.3.1.7 Key Issue #7: Tampering of DL C-Plane messages in a switched fronthaul network + +##### 4.3.1.7.1 Introduction + +C-Plane messages may contain control information necessary for the O-RU like resource mapping, beamforming, and DL power control to properly perform its tasks. Switched fronthaul networks are described as LLS-C2, LLS-C3 and LLS-C4 types of fronthaul networks in [i.5], clause 11.2.2. + +##### 4.3.1.7.2 Threats + +Depending on the installation topology, the O-DU and O-RU can be in physically separate locations. The network path between the O-DU and O-RU can be publicly accessible and does not require any physical access protections. The network interface is an industry standard interface with publicly available testing and analysis tools. + +An attacker may tamper DL C-Plane messages to + +- Distort the mapping of the logical flows onto the physical resources. +- Distort the beamforming (the UE does not receive the signal as the beams are modified). +- Modify the commands for DL power, possibly leading to inadequacy between the MCS and the DL power, leading to insufficient SINR or, conversely, PA saturation. +- Issue Network Energy Saving C-Plane commands that turn off the O-RU disrupting all traffic. + +As a result, this would result in cell unavailability, leading temporarily to DoS. + +##### 4.3.1.7.3 Risk analysis + +This risk analysis expects that no security measures are applied, i.e. the network is set up as a single broadcast region and all messages are unprotected. + +Impact: High + +Likelihood: Medium - An attacker needs access to the network transporting C-Plane messages. Depending on the installation topology, the network path between the O-DU and O-RU can be publicly accessible. + +##### 4.3.1.7.4 Potential Security Requirements + +[REQ-1] Authenticated integrity protection should protect all C-Plane data flows through the fronthaul network, as that would eliminate all options for an attacker of tampering with or injecting C-Plane messages. + +[REQ-2] Further security measures include: + +- **Network Segmentation:** Implementing network segmentation to isolate critical systems from the rest of the network. This limits the potential impact of a C-Plane protocol stack vulnerability by containing the attack within a smaller network segment. +- **Intrusion Detection and Prevention Systems (IDPS):** Deploying IDPS solutions to monitor network traffic and detect potential IP stack attacks in real-time. These systems can identify and block malicious activities, providing an additional layer of defense against exploitation. +- **Implementing a ZTA with MACsec e2e or hop-by-hop protecting the C-Plane.** + +NOTE 1: Authenticated integrity protection does not prevent an attacker from blocking the control messages which could also lead to DoS and cell unavailability. + +#### 4.3.1.8 Key Issue #8: C-Plane protocol stack vulnerability attacks in a switched fronthaul network + +##### 4.3.1.8.1 Introduction + +Attackers may exploit vulnerabilities in the implementation of the protocol stack termination points on the O-RAN Open Fronthaul C-Plane. Switched fronthaul networks are described as LLS-C2, LLS-C3 and LLS-C4 types of fronthaul networks in [i.5], clause 11.2.2. + +##### 4.3.1.8.2 Threats + +Threats of attackers exploiting vulnerabilities include + +- **Remote Code Execution:** If an attacker successfully exploits a vulnerability in the C-Plane protocol stack implementation, they can execute arbitrary code on the target system. This can lead to unauthorized access, data breaches, and further compromise of the O-RU or O-DU. +- **Information Disclosure:** Vulnerabilities in the C-Plane protocol stack can lead to unintended information disclosure, such as leaking sensitive data or exposing system configurations. Attackers can exploit these vulnerabilities to gain valuable insights about the targeted system, which can be used for further attacks. +- **Protocol Exploitation:** Exploiting protocol vulnerabilities can lead to unauthorized access, network manipulation, or the injection of malicious packets into the network. + +##### 4.3.1.8.3 Risk analysis + +This risk analysis expects that no security measures are applied, i.e. the network is set up as a single broadcast region and all messages are unprotected. + +Impact: High + +Likelihood: Medium; An attacker needs physical access to the network transporting C-Plane messages. + +##### 4.3.1.8.4 Potential Security Requirements + +[REQ-1] Authenticated integrity protection should protect all C-Plane data flows through the fronthaul network, as that would eliminate all options for an attacker of exploiting vulnerabilities in the C-Plane protocol stack. + +[REQ-2] Further security measures include: + +- **Regular Patching and Updates:** Keeping the C-Plane related software up to date by regularly applying security patches and updates provided by the vendor. This ensures that known vulnerabilities are fixed, reducing the risk of exploitation. +- **Network Segmentation:** Implementing network segmentation to isolate critical systems from the rest of the network. This limits the potential impact of a C-Plane protocol stack vulnerability by containing the attack within a smaller network segment. +- **Intrusion Detection and Prevention Systems (IDPS):** Deploying IDPS solutions to monitor network traffic and detect potential IP stack attacks in real-time. These systems can identify and block malicious activities, providing an additional layer of defense against exploitation. + +### 4.3.2 Solutions + +#### 4.3.2.1 Solution1: Layer-2 MACsec for protecting C-plane messages + +The clear text nature of the C-Plane messages over the Ethernet exposes the open-fronthaul to the threats and risks identified in clause 4.3.1. + +MACsec [i.9] is a Layer 2 security protocol providing data confidentiality, frame data integrity, and authenticity of data origin including replay protection. It ensures that data transmitted over Ethernet networks is protected from eavesdropping, denial of service, passive monitoring, and tampering, and replay. + +The recommendation is to establish MACsec between the O-RU and O-DU in an End-to-End tunnel mode or hop-by-hop mode. With End-to-End mode, the intermediary switches need not be MACsec aware, overcoming deployment challenges faced in hop-by-hop MACsec. + +As per the guidelines provided in IEEE 802.1AE-2018[i.9], C-Plane data should be protected using MACsec in scenarios where the O-RU and O-DU are in two separate locations connected via a switched fronthaul network. + +In this solution, the functional blocks of controlled port, uncontrolled port, and Ethernet Data Encryption (EDE), as defined in the standard IEEE 802.1AE -2018[i.9] clauses 5.2, 5.3 and 15.6 are used to selectively apply MACsec for C-plane messages. + +Clause 4.6.2 provides an End-to-End solution of protecting the Open FH Interface. The C-plane messages are sent on controlled port where MACsec is applied, while S-plane messages are not protected by MACsec. + +### 4.3.3 Evaluation and Conclusions + +#### 4.3.3.1 Evaluation + +MACsec is a viable solution for securing C-Plane traffic in the Open Fronthaul network. This solution addresses the key issue#3, #4, #6 in clause 4.3.1. + +#### 4.3.3.2 Conclusion + +IEEE 802.1AE-2018[i.9] MACsec is recommended as a solution to protect C-plane messages on the Open Fronthaul interface. + +MACsec is configured in an End-to-End tunnel mode or Hop-by-Hop mode. Hop-by-Hop mode requires the intermediate nodes to support MACsec. End-to-End mode does not require the intermediate nodes to support MACsec. Due to the additional need for MACsec resources (number of needed SecYs/SCs), networks using End-to-End mode are generally more limited in size (size as number of fully interconnected peers across a PBN) relative to networks using Hop-by-Hop MACsec. Due to the per-hop need for MACsec de- and encryption procedures which processing times draw from the End-to-End latency budget, networks using Hop-by-Hop mode are generally more limited in size (size as the maximum overall path length throughout the PBN) relative to networks using End-to-End MACsec. + +## 4.4 Security for U-Plane + +### 4.4.1 Key Issues + +#### 4.4.1.1 Key Issue #1: Tampering of U-Plane messages. + +##### 4.4.1.1.1 Introduction + +U-Plane messages contain information necessary like the I/Q and RACH packets to properly perform its tasks. + +##### 4.4.1.1.2 Threats + +An attacker may + +- Tamper with I/Q packets OR +- Discard valid I/Q packets and replaces them by fake ones. +- Tamper with RACH messages OR + +- Discard valid RACH packets and replaces them by fake ones. + +As a result, this would result in cell unavailability. + +##### 4.4.1.1.3 Risk analysis + +Impact: High + +Likelihood: Medium + +An attacker needs access to the network transporting U-Plane messages. + +##### 4.4.1.1.4 Potential Security Requirements + +[REQ-1] Authenticated integrity protection should protect all U-Plane data flows through the fronthaul network and would eliminate all option for an attacker of tampering. + +### 4.4.2 Solutions + +#### 4.4.2.1 Solution1: Layer-2 MACsec for protecting U-Plane messages + +The U-Plane data packets that carry information related to I/Q samples and PRACH are transported over Open Fronthaul as encapsulated Ethernet packets and are not integrity protected. These messages are susceptible to attacks described in clause 4.4.1.1. Additionally, an adversary can also tamper with the eCPRI and O-RAN headers that remain unprotected. + +The Packet Data Convergence Protocol (PDCP) [i.17] provides confidentiality and integrity protection of 5G System Control Plane and User Plane between O-CU-CP and UE, and O-CU-UP and UE, However, the above messages are not protected by PDCP. + +MACsec [i.9], Layer 2 security protocol providing data confidentiality, frame data integrity, and authenticity of data origin is considered as a potential solution for protecting U-Plane data. It ensures that data transmitted over Ethernet networks is protected from eavesdropping, denial of service, passive monitoring, and tampering. + +One of the concerns for proposing MACsec as potential security solution for U-Plane is the impact on Performance. However, with the MACsec evolving from local-area network (LAN) encryption technology to a much wider area in WAN transport along with Hardware based encryption and decryption enables to meet the performance and latency requirements in an Open Fronthaul network. + +The potential solution is to enable MACsec[i.9] in an End-to-End tunnel mode for protecting U-Plane messages[PRACH, PUCCH,SSB, O-RAN Application and eCPRI headers] in the Open FH network. The decision to enable MACsec on the fronthaul network elements depends on the specific deployment scenarios outlined in the Fronthaul CUS Plane Security Analysis Technical Report. With this solution the intermediary switches need not be MACsec aware, and we overcome the deployment challenges faced in hop-by-hop MACsec. + +In this solution, the functional blocks of controlled port, uncontrolled port, and Ethernet Data Encryption (EDE), as defined in the standard IEEE 802.1AE -2018[i.9] clauses 5.2, 5.3 and 15.6 are used to selectively apply MACsec for C-Plane and U-Plane messages. + +Clause 4.6.2 provides an e2e solution of protecting the Open FH Interface. The C,U-Plane messages are sent on controlled port where MACsec is applied, while S-plane messages are transmitted unprotected on uncontrolled port. + +### 4.4.3 Evaluation and Conclusions + +#### 4.4.3.1 Evaluation + +MACsec is a viable solution for securing U-Plane traffic in the Open Fronthaul network. This solution addresses the key issue#1 clause 4.4.1. Based on the topology options described in clause 4.6.3 MACsec can be enabled at various elements constituting the Open Fronthaul network. + +#### 4.4.3.2 Conclusion + +IEEE 802.1AE-2018[i.9] MACsec is recommended as a solution to protect U-plane messages on the Open Fronthaul interface. + +Hop-by-hop mode requires the intermediate nodes to support MACsec. End-to-end mode does not require the intermediate nodes to support MACsec. Due to the additional need for MACsec resources (number of needed SecYs/SCs), networks using end-to-end mode are generally more limited in size (size as number of fully interconnected peers across a PBN) relative to networks using hop-by-hop MACsec. Due to the per-hop need for MACsec de- and encryption procedures which processing times draw from the end-to-end latency budget, networks using hop-by-hop mode are generally more limited in size (size as the maximum overall path length throughout the PBN) relative to networks using end-to-end MACsec. + +## 4.5 Security for Fronthaul Ethernet L1 physical layer interface + +### 4.5.1 Key Issues + +#### 4.5.1.1 Key Issue #1: Unauthorized access to Open Fronthaul Ethernet L1 physical layer interface(s) + +##### 4.5.1.1.1 Introduction + +The Open Fronthaul Ethernet L1 physical interface comprises one or more coaxial cables, twisted pairs, or optical fibers. Each end of the Open Fronthaul Ethernet L1 physical interface comprises a physical connection (colloquially known as an Ethernet Port) to physical O-RAN network elements, e.g., O-DU, O-RU, etc., as described in [i.5] and [i.7]. + +Unauthorized access to the Open Fronthaul Ethernet L1 physical layer interface (cables and connections) provides a means to launch attacks on the availability, integrity, and confidentiality of the Open Fronthaul system. + +##### 4.5.1.1.2 Threats + +Potential loss of availability on the Open Fronthaul interface can occur from one or more of the following threats: + +- An unauthorized device on the Ethernet L1 Interface can flood the L1 interface with unintended network traffic causing disruption or degradation of authorized network elements on the Open Fronthaul interface. +- An unauthorized device on the Ethernet L1 Interface can send L2 messages to authorized network devices causing disruption, denial, or degradation of the Open Fronthaul interface. This threat enables the attacks described in Key Issue 1, 2, and others. +- An attacker (person) gains access to the Open Fronthaul Ethernet L1 interface(s) and denies the Open Fronthaul services by disabling a physical connection to a network element either by removing an Ethernet port connection or cutting the physical interface (coaxial cable, twisted pair, or optical fibre). + +Potential loss of availability, confidentiality, and/or integrity on the Open Fronthaul interface can occur from one or more of the following threats: + +- An unauthorized device on the Ethernet L1 Interface has access to U-Plane traffic on the Open Fronthaul Interface. +- An unauthorized device on the Ethernet L1 Interface has access to S-Plane traffic on the Open Fronthaul Interface. +- An unauthorized device on the Ethernet L1 Interface has access to C-Plane traffic on the Open Fronthaul Interface. +- An unauthorized device on the Ethernet L1 Interface has access to M-Plane traffic on the Open Fronthaul Interface. + +##### 4.5.1.1.3 Risk Analysis + +Impact: Depends upon effect from carrying out a threat. + +Likelihood: High + +##### 4.5.1.1.4 Potential Security Requirements + +[REQ-X1] The security mechanism for PTP shall provide a means to authenticate and authorize Ethernet Layer 1 physical connections between O-RAN network elements comprising an Open Fronthaul Interface. + +[REQ-X2] The security mechanism for PTP shall provide a means to detect and report when an authorized Ethernet Layer 1 physical connection is made or broken. + +### 4.5.2 Solutions + +#### 4.5.2.1 Solution #1 Port Based Access Control for Open Fronthaul Network + +This solution addresses KI #1 in clause 4.5.1.1. + +Zero trust principles [i.3] call for least privileged access where the Open Fronthaul network should only allow network access to authorized network elements. IEEE 802.1X-2020 Port-based Network Access Control (NAC) [i.4] may be used to restrict access in point-to-point LAN segments within the Open Fronthaul network. + +The scope of these requirements span those relevant to the O-RAN Alliance Open Fronthaul comprising port-based network control between supplicant and authenticator entities described in IEEE 802.1X-2020 and as further described in this section. All other entities and functionality described in IEEE 802.1X are out of scope of this O-RAN Alliance specification. + +[REQ1] Operator implementation of IEEE 802.1X-2020 for Open Fronthaul port-based network access control is optional to use for each point-to-point LAN segment. + +##### Supplicants in the Open Fronthaul Network + +An Open Fronthaul Network element is an entity in a point-to-point LAN segment. Examples of O-RAN Alliance defined Open Fronthaul network elements include, but are not limited to, O-DU, O-RU, switches, FHM, FHGW, and PRTC-T/GM [i.5][i.6][i.7]. + +[REQ 2] Open Fronthaul network elements shall support IEEE 802.1X-2020 NAC supplicant functionality for each Port connection in the Open Fronthaul network element. + +##### Authenticators in the Open Fronthaul Network + +In IEEE 802.1X-2020 NAC a supplicant mutually authenticates with an authenticator. + +[REQ 3] Any Open Fronthaul network element may be an authenticator in the Open Fronthaul network. + +[REQ 4] An authenticator in an Open Fronthaul network shall perform port-based access control on each point-to-point LAN segment as defined in IEEE 802.1X-2020 NAC. + +[REQ 5] IEEE 802.1X-2020 NAC between a supplicant and authenticator in an Open Fronthaul network shall use EAP - TLS authentication. + +##### O-DU as an Authenticator + +Configuration LLS-C1 [i.5] and Cascade Mode in the Shared Cell Concept [i.5] are cases where an O-DU and O-RU are Open Fronthaul network elements in a point-to-point LAN segment. + +[REQ 6] In the case of Configuration LLS-C1, the O-DU must support the authenticator functionality as defined in IEEE 802.1X-2020 NAC. + +[REQ 7] In the case of Cascade Mode in the Shared Cell Concept, the O-DU must support the authenticator functionality as defined in IEEE 802.1X-2020 NAC. + +##### O-RU as an Authenticator + +Cascade Mode in the Shared Cell Concept [i.5] is a case where an O-RU may be in a point-to-point LAN segment with another O-RU. + +##### **Other requirements** + +The following requirements are outside the scope of the Open Fronthaul and should be included in an appropriate O-RAN Alliance document. + +##### Certificate Management + +[REQ X] Bootstrap process for obtaining an operator X.509 certificate on a network element using CMPv2. + +[REQ Y] X.509 certificate renewal for all network elements using CMPv2. + +## 4.6 Security at Fronthaul Layer 2 using MACsec + +### 4.6.1 Introduction + +MACsec defined in the standard IEEE 802.1AE -2018[i.9] is a Layer 2 protocol that provides data confidentiality, frame data integrity, and authenticity of data origin including replay protection for all types of traffic on Ethernet links. + +### 4.6.2 MACsec Solution Proposals for Fronthaul Security Protection + +MACsec can be configured in an End-to-End mode or Hop-by-Hop mode. Hop-by-Hop mode requires the intermediate nodes to support MACsec. End-to-End mode does not require the intermediate nodes to support MACsec. + +MACsec configuration can be applied per VLAN or at the base interface level. This clause discusses potential solutions for O-DU and O-RU to establish MACsec using one of the below encryption modes. + +1. MACsec using EDE-CC +2. WAN mode MACsec +3. LAN mode MACsec + +The MACsec solution proposals 1 and 2 described below allows to apply MACsec per VLAN. The solutions enable selective filtering of traffic requiring encryption (C-Plane, U-Plane) from traffic(S-Plane) that does not require encryption in the Open Fronthaul network. + +The MACsec solution proposal 3 applies MACsec at the base interface level and encrypts all traffic planes. + +#### 4.6.2.1 Solution 1# MACsec using EDE-CC + +MACsec using EDE-CC involves EDE-CC, controlled port, uncontrolled port as functional blocks from IEEE 802.1AE[i.9] . This solution applies to scenarios where MACsec is applied based on VLAN tags and configured at the VLAN interface. This mode allows 802.1Q VLAN tags to be encrypted inside the MACsec header and also sent in clear text, outside the MACsec header. The inner VLAN tag is protected by MACsec while the outer VLAN tag is used for VLAN based switching in a network where some transport network elements may not be MACsec capable. This solution enables MACsec to be configured in an End-to End mode and the intermediate nodes do not need to support MACsec. + +To prevent intermediary nodes from consuming MACsec packets, it is recommended to configure the group destination address as specified in IEEE 802.1AE-2018, Table 15.1. + +![Diagram illustrating the MACsec using EDE-CC solution proposal for fronthaul security protection. The diagram shows O-DU and O-RU connected via a Fronthaul cloud. O-DU and O-RU each have an Uncontrolled Port and a Controlled Port. EDE-CC is shown as a functional block within the Controlled Port. Traffic flows are shown: PTP data (G.8275.1 PTP) is sent unencrypted between adjacent switches. C and U-Plane traffic is encrypted using MACsec and sent through the Controlled Port. The diagram also shows the structure of the MACsec header, including PTP data, EtherType, SA, and DA, and the structure of the VLAN tag, including eCPRI data, VLAN Tag, and SA/DA.](564b40b514f14f3ad3259168d4df7ee1_img.jpg) + +Diagram illustrating the MACsec using EDE-CC solution proposal for fronthaul security protection. The diagram shows O-DU and O-RU connected via a Fronthaul cloud. O-DU and O-RU each have an Uncontrolled Port and a Controlled Port. EDE-CC is shown as a functional block within the Controlled Port. Traffic flows are shown: PTP data (G.8275.1 PTP) is sent unencrypted between adjacent switches. C and U-Plane traffic is encrypted using MACsec and sent through the Controlled Port. The diagram also shows the structure of the MACsec header, including PTP data, EtherType, SA, and DA, and the structure of the VLAN tag, including eCPRI data, VLAN Tag, and SA/DA. + +Figure 4.6.2.1-1 MACsec using EDE-CC solution proposal for fronthaul security protection + +As shown in the Fig 4.6.2.1-1, the concept of controlled port, uncontrolled port, and Ethernet Data Encryption (EDE) from IEEE 802.1AE standard for MACsec [i.9] are used as functional blocks integrated within O-DU or O-RU. While transmitting, O-DU sends PTP messages unprotected whereas all C and U-Plane traffic travel towards the controlled port. This demultiplexing operation can be done based upon checking PTP EtherType for G.8275.1 profile. PTP messages go out from the hardware port and remain unprotected by MACsec. All the other traffic goes through an EDE functional block which protects traffic using MACsec. In the above figure, the EDE-CC, a variant of EDE, adds a cleartext VLAN header before MACsec header, which includes VLAN as well as VLAN PCP bits that are used for + +VLAN-based switching and identifying QoS profile in the MACsec unaware Fronthaul TNE connected to O-DU. While receiving, O-RU maps PTP messages to uncontrolled port and all the other traffic to an EDE. Again, PTP EtherType can be used for this demultiplexing operation. Through uncontrolled port, PTP messages go to 1588 layer in O-RU functional block. All the other traffic which is received by EDE is validated using MACsec and upon successful validation sent towards O-RU functional block through controlled port. Communication from O-RU towards O-DU happens in a similar manner. + +The MACsec solution using EDE-CC can be configured in an End-to-End mode at various points within an Open Fronthaul network, as elucidated in the topology scenarios below. The functional blocks of controlled, uncontrolled port and EDE-CC can be integrated into O-DU, O-RU, TNE, FHM based on the MACsec tunnel endpoints. + +#### 4.6.2.2 Solution 2# WAN mode MACsec + +This solution applies to scenarios where MACsec is applied based on VLAN tags and configured at the VLAN interface. This mode allows the 802.1Q VLAN tag to be unencrypted and sent in clear text, outside the MACsec header. This enables intermediate switches that are MACsec-unaware to route the packets based on the VLAN tag. To prevent MACsec capable intermediary nodes from consuming MACsec packets, it is recommended to configure the group destination address to allow the intermediary nodes to forward the packets like any other data packet. + +In addition to EDEs a similar solution to expose a VLAN header in clear text exists which some products on the market currently support. It is a non-standard, proprietary, addition to the IEEE Std 802.1AE, requiring the 802.1AE header to be inserted after the VLAN header(s). The industry refers to this mode as e.g. ‘WAN mode’, ‘VLAN in the clear’ or ‘Bypassed Tags’. As support for EDEs at this time is low across the market, this mode can be considered for specification to become optionally supported for backwards compatibility. The only difference to the EDE modes is that the receiver cannot check whether the VLAN header in front of the MACsec header has been altered, but in both cases the VLAN header in the clear is not protected until it reaches the receiver. In EDE, the outer unprotected VLAN is typically not used by the receiving entity and the original VLAN header is protected by MACsec. In WAN mode, the original VLAN header is not protected by MACsec and is open for attacks. + +![Diagram of WAN mode MACsec frame structure. A horizontal bar represents the frame, divided into eight segments: DMAC, SMAC, 802.1Q, 802.1AE header, ETYPE, Payload, ICV, and FCS. A green bracket above the bar spans from DMAC to SMAC, and another green bracket above the bar spans from 802.1AE header to FCS. A green bracket below the bar spans from ETYPE to ICV. The label 'Authenticated (Integrity)' is centered above the first bracket. The label 'Encrypted (Confidentiality)' is centered below the third bracket.](5de6764bed70ffbd099764b727d380c0_img.jpg) + +Authenticated (Integrity) + +Encrypted (Confidentiality) + +Diagram of WAN mode MACsec frame structure. A horizontal bar represents the frame, divided into eight segments: DMAC, SMAC, 802.1Q, 802.1AE header, ETYPE, Payload, ICV, and FCS. A green bracket above the bar spans from DMAC to SMAC, and another green bracket above the bar spans from 802.1AE header to FCS. A green bracket below the bar spans from ETYPE to ICV. The label 'Authenticated (Integrity)' is centered above the first bracket. The label 'Encrypted (Confidentiality)' is centered below the third bracket. + +**Figure 4.6.2.2-1 ‘WAN mode’, for fronthaul security protection** + +#### 4.6.2.3 Solution 3# LAN mode MACsec + +This solution requires that the entire Ethernet frame after the MAC address should be encrypted. When MACsec is configured at the interface level (base-interface) of an open fronthaul network element, the Secure TAG of MACsec encompasses both VLAN-tagged and non-VLAN-tagged frames, securing all traffic that travels through the interface. + +It may be possible to configure additional policies to bypass MACsec protection based on EtherType, VLAN ID, and destination address. When enabled, this capability allows certain types of Open Fronthaul traffic, such as S-Plane, to remain unencrypted and bypass MACsec protection. + +Editor’s Note 1: The informative call flow for End-to-End MACsec is still FFS. + +Editor’s Note 2: The key management for MACsec is still FFS. + +### 4.6.3 Deployment consideration for MACsec in Open Fronthaul + +#### 4.6.3.1 Introduction + +The choice of enabling MACsec on Open Fronthaul should be based on deployment aspects that may include network topology, device capabilities, and traffic types to be encrypted. Additionally, the deployment strategy should align with the specific security and performance requirements of the network . + +MACsec can be configured in an End-to-End mode or Hop-by-Hop mode using any one of the encryption modes as described in clause 4.6.2. + +This clause studies the deployment considerations for enabling MACsec in End-to-End Mode, as well as for PTP traffic and Shared O-RU scenarios. + +##### 4.6.3.1.1 Deployment considerations for End-to-End MACsec + +###### 4.6.3.1.1.1 Scenario 1: MACsec enabled at O-DU and O-RU + +This option explores enabling MACsec at the O-RU and O-DU in an End-to-End mode, offering a secure communication pathway without requiring MACsec awareness in the transport network elements. The communication between the O-RU and O-DU is fortified with encryption, protecting against eavesdropping and unauthorized access. + +This scenario is Zero Trust Architecture compliant from the Cell Site O-RU to the O-DU. + +![Diagram of Scenario 1: MACsec enabled at O-DU and O-RU. The diagram shows a Cell Site on the left containing an O-RU (orange box) and TNE1 (purple circle). A Centralized Site on the right contains TNE2 (purple circle), O-DU (blue box), and O-CU (green box). An 'Open Front Haul' cloud connects TNE1 and TNE2. A red double-headed arrow labeled 'Tunneled E2E MACsec' spans from the O-RU to the O-DU, indicating encryption across the entire path.](f9899feabd96421800e7d7a3b400406b_img.jpg) + +Diagram of Scenario 1: MACsec enabled at O-DU and O-RU. The diagram shows a Cell Site on the left containing an O-RU (orange box) and TNE1 (purple circle). A Centralized Site on the right contains TNE2 (purple circle), O-DU (blue box), and O-CU (green box). An 'Open Front Haul' cloud connects TNE1 and TNE2. A red double-headed arrow labeled 'Tunneled E2E MACsec' spans from the O-RU to the O-DU, indicating encryption across the entire path. + +Figure 4.6.3.1.1.1-1 MACsec enabled at O-RU and O-DU + +###### 4.6.3.1.1.2 Scenario 2: MACsec enabled at the Transport Network elements at the edge of Cell site and Central Site + +In this configuration, MACsec is activated on the edge transport network elements located at both the cell site and central site. The O-RU transmits unencrypted C-Plane messages to TNE1, where they are encrypted and subsequently tunneled to TNE2 at the central site. + +This scenario is Zero Trust Architecture compliant from the Cell Site TNE1 to the TNE2. + +![Diagram of Scenario 2: MACsec enabled at edge Transport Network Elements. The diagram shows a Cell Site on the left containing an O-RU (orange box) and TNE1 (purple circle). A Centralized Site on the right contains TNE2 (purple circle), O-DU (blue box), and O-CU (green box). An 'Open Front Haul' cloud connects TNE1 and TNE2. A red double-headed arrow labeled 'Tunneled E2E MACsec' spans from TNE1 to TNE2, indicating encryption between the transport network elements.](1093a7b69f5a915e7ed2731e41cbbc3d_img.jpg) + +Diagram of Scenario 2: MACsec enabled at edge Transport Network Elements. The diagram shows a Cell Site on the left containing an O-RU (orange box) and TNE1 (purple circle). A Centralized Site on the right contains TNE2 (purple circle), O-DU (blue box), and O-CU (green box). An 'Open Front Haul' cloud connects TNE1 and TNE2. A red double-headed arrow labeled 'Tunneled E2E MACsec' spans from TNE1 to TNE2, indicating encryption between the transport network elements. + +Figure 4.6.3.1.1.2-1 MACsec enabled at edge Transport Network Elements + +###### 4.6.3.1.1.3 Scenario 3: MACsec enabled at the O-RU at Cell site and edge TNE at the Central Site + +In this scenario, MACsec is activated on the O-RU located at the cell site, which is connected to a TNE. The End-to-End MACsec is established between the O-RU and TNE2 at the central site. The encrypted C-Plane traffic is then tunneled through the MACsec-unaware TNEs within the Open Fronthaul network. + +This scenario is Zero Trust Architecture compliant from the Cell Site O-RU to the TNE2. + +![Diagram of Scenario 3: MACsec enabled at O-RU and TNE2. The diagram shows a Cell Site with an O-RU (orange box) and TNE1 (purple circle). A Centralized Site has TNE2 (purple circle), O-DU (blue box), and O-CU (green box). An Open Front Haul cloud connects TNE1 and TNE2. A red double-headed arrow labeled 'Tunneled E2E MACsec' spans from O-RU to TNE2.](e139b338bc7401ea21ea3a26e0f8ff4f_img.jpg) + +Diagram of Scenario 3: MACsec enabled at O-RU and TNE2. The diagram shows a Cell Site with an O-RU (orange box) and TNE1 (purple circle). A Centralized Site has TNE2 (purple circle), O-DU (blue box), and O-CU (green box). An Open Front Haul cloud connects TNE1 and TNE2. A red double-headed arrow labeled 'Tunneled E2E MACsec' spans from O-RU to TNE2. + +Figure 4.6.3.1.1.3-1 MACsec enabled at O-RU and TNE2 + +###### 4.6.3.1.1.4 Scenario 4: MACsec enabled Cell site TNE and O-DU at the Central Site + +In this scenario, MACsec is activated on the TNE1 located at the cell site. The End-to-End MACsec is established between the TNE1 and O-DU at the central site. The encrypted traffic is then tunneled through the MACsec-unaware TNEs within the Open Fronthaul network. + +This scenario is Zero Trust Architecture compliant from the Cell Site TNE1 to the O-DU. + +NOTE: When DU is hosted on the O-Cloud, MACsec termination will occur at the O-Cloud. + +![Diagram of Scenario 4: MACsec enabled at TNE1 and O-DU. The diagram shows a Cell Site with an O-RU (orange box) and TNE1 (purple circle). A Centralized Site has TNE2 (purple circle), O-DU (blue box), and O-CU (green box). An Open Front Haul cloud connects TNE1 and TNE2. A red double-headed arrow labeled 'Tunneled E2E MACsec' spans from TNE1 to O-DU.](efa9ac35d7b480da886000414df3283d_img.jpg) + +Diagram of Scenario 4: MACsec enabled at TNE1 and O-DU. The diagram shows a Cell Site with an O-RU (orange box) and TNE1 (purple circle). A Centralized Site has TNE2 (purple circle), O-DU (blue box), and O-CU (green box). An Open Front Haul cloud connects TNE1 and TNE2. A red double-headed arrow labeled 'Tunneled E2E MACsec' spans from TNE1 to O-DU. + +Figure 4.6.3.1.1.4-1 MACsec enabled at TNE1 and O-DU + +###### 4.6.3.1.1.5 Scenario 5: MACsec enabled at O-DU and O-RU + +In this configuration, MACsec is activated on the O-RU and O-DU connection that is directly connected to each other with no transport network elements. The communication between the O-RU and O-DU is fortified with encryption, protecting against eavesdropping, and unauthorized access. This scenario is Zero Trust Architecture compliant from the Cell Site O-RU to the O-DU. + +NOTE: When DU is hosted on the O-Cloud, MACsec termination will occur at the O-Cloud. + +![Figure 4.6.3.1.1.5-1: MACsec enabled at O-DU and O-RU. The diagram shows a Cell Site with an O-RU (orange box) and a Centralized Site with an O-DU (blue box) and an O-CU (green box). A double-headed arrow connects the O-RU and O-DU. A large red arrow labeled 'E2E MACsec' spans the entire distance between the Cell Site and Centralized Site.](81443bac700d5694ea8c09b0faf7a79c_img.jpg) + +Figure 4.6.3.1.1.5-1: MACsec enabled at O-DU and O-RU. The diagram shows a Cell Site with an O-RU (orange box) and a Centralized Site with an O-DU (blue box) and an O-CU (green box). A double-headed arrow connects the O-RU and O-DU. A large red arrow labeled 'E2E MACsec' spans the entire distance between the Cell Site and Centralized Site. + +Figure 4.6.3.1.1.5-1 MACsec enabled at O-DU and O-RU + +##### 4.6.3.1.1.6 Scenario 6: MACsec enabled at O-RU and TNE at the Central Site + +In this configuration, MACsec is activated on the O-RU and TNE connection that is directly connected to each other with no transport network elements. The communication between the O-RU and TNE is fortified with encryption, protecting against eavesdropping, and unauthorized access. This scenario is Zero Trust architecture-compliant from the Cell Site O-RU to the TNE. + +![Figure 4.6.3.1.1.6-1: MACsec enabled at O-RU and TNE at the Central Site. The diagram shows a Cell Site with an O-RU (orange box) and a Centralized Site with a TNE (purple circle), an O-DU (blue box), and an O-CU (green box). A double-headed arrow connects the O-RU and TNE. A large red arrow labeled 'E2E MACsec' spans the entire distance between the Cell Site and Centralized Site.](bff88cc496db29b8556a47f85f6b3510_img.jpg) + +Figure 4.6.3.1.1.6-1: MACsec enabled at O-RU and TNE at the Central Site. The diagram shows a Cell Site with an O-RU (orange box) and a Centralized Site with a TNE (purple circle), an O-DU (blue box), and an O-CU (green box). A double-headed arrow connects the O-RU and TNE. A large red arrow labeled 'E2E MACsec' spans the entire distance between the Cell Site and Centralized Site. + +Figure 4.6.3.1.1.6-1 MACsec enabled at O-RU and TNE at the Central Site + +###### 4.6.3.1.1.7 Scenario 7: MACsec enabled at FHM and O-DU at the Central Site + +In this configuration of Shared Cell, MACsec is activated on the FHM and O-DU that is directly connected to each other with no transport network elements. The communication between the FHM and O-DU is fortified with encryption, protecting against eavesdropping, and unauthorized access. This scenario is Zero Trust architecture-compliant from the Cell Site FHM to the O-DU. + +NOTE: When DU is hosted on the O-Cloud, MACsec termination will occur at the O-Cloud. + +![Figure 4.6.3.1.1.7-1: MACsec enabled at FHM and O-DU at the Central Site. The diagram shows a Cell Site with three O-RU (orange boxes) connected to a central FHM (yellow circle). The FHM is connected to an O-DU (blue box) in the Centralized Site, which is also connected to an O-CU (green box). A double-headed arrow connects the FHM and O-DU. A large red arrow labeled 'E2E MACsec' spans the entire distance between the Cell Site and Centralized Site.](108a643709225785e667648d8b042971_img.jpg) + +Figure 4.6.3.1.1.7-1: MACsec enabled at FHM and O-DU at the Central Site. The diagram shows a Cell Site with three O-RU (orange boxes) connected to a central FHM (yellow circle). The FHM is connected to an O-DU (blue box) in the Centralized Site, which is also connected to an O-CU (green box). A double-headed arrow connects the FHM and O-DU. A large red arrow labeled 'E2E MACsec' spans the entire distance between the Cell Site and Centralized Site. + +Figure 4.6.3.1.1.7-1 MACsec enabled at FHM and O-DU at the Central Site + +###### 4.6.3.1.1.8 Scenario 8: MACsec enabled at TNE at Cell site and O-DU at the Central Site + +In this configuration of Shared Cell, MACsec is activated on the TNE at cell-site and O-DU at central site. The End-to-End MACsec is established between the TNE and O-DU at the central site. The encrypted traffic is then tunneled through the MACsec-unaware TNEs within the Open Fronthaul network. + +This scenario is Zero Trust Architecture compliant from the Cell Site TNE to the O-DU. + +NOTE: When DU is hosted on the O-Cloud, MACsec termination will occur at the O-Cloud. + +![Figure 4.6.3.1.1.8-1: Network diagram showing MACsec enabled at FHM and O-DU at the Central Site. The diagram is divided into two main sections: 'Cell Site' and 'Centralized Site'. In the 'Cell Site', three O-RU blocks are connected to a central FHM (Fiber Home Module) block, which is in turn connected to a TNE (TNE) block. In the 'Centralized Site', there is an O-DU block connected to an O-CU block. A cloud labeled 'Open Front Haul' connects the TNE to the O-DU. A large red double-headed arrow labeled 'Tunneled E2E MACsec' spans the Open Front Haul cloud, indicating the secure tunnel between the TNE and O-DU.](c12067f3658487aaa13073f1ceda04d7_img.jpg) + +Figure 4.6.3.1.1.8-1: Network diagram showing MACsec enabled at FHM and O-DU at the Central Site. The diagram is divided into two main sections: 'Cell Site' and 'Centralized Site'. In the 'Cell Site', three O-RU blocks are connected to a central FHM (Fiber Home Module) block, which is in turn connected to a TNE (TNE) block. In the 'Centralized Site', there is an O-DU block connected to an O-CU block. A cloud labeled 'Open Front Haul' connects the TNE to the O-DU. A large red double-headed arrow labeled 'Tunneled E2E MACsec' spans the Open Front Haul cloud, indicating the secure tunnel between the TNE and O-DU. + +Figure 4.6.3.1.1.8-1 MACsec enabled at FHM and O-DU at the Central Site + +##### 4.6.3.1.2 Deployment consideration for PTP traffic + +In the following clause, the focus is on the MACsec option for securing the C-Plane and M-Plane traffic under Open Fronthaul deployment topologies described in [i.5]. + +###### 4.6.3.1.2.1 MACsec in LLS-C1 topology running PTP G.8275.1 profile + +![Figure 4.6.3.1.2.1-1: Diagram illustrating C-Plane and M-Plane protection based on MACsec in LLS-C1 topology. It shows two red circular nodes: 'O-DU' on the left (labeled 'T-GM') and 'O-RU' on the right (labeled 'T-TSC'). Three horizontal lines connect them: a top red line labeled 'PTP over Eth session (MACSec protection optional)', a middle green line labeled 'Protected eCPRI/M-plane', and a bottom purple line labeled 'MACSec CA'. The T-GM and T-TSC labels are positioned below their respective nodes.](9e1d1267f6345638c923981b86d4e548_img.jpg) + +Figure 4.6.3.1.2.1-1: Diagram illustrating C-Plane and M-Plane protection based on MACsec in LLS-C1 topology. It shows two red circular nodes: 'O-DU' on the left (labeled 'T-GM') and 'O-RU' on the right (labeled 'T-TSC'). Three horizontal lines connect them: a top red line labeled 'PTP over Eth session (MACSec protection optional)', a middle green line labeled 'Protected eCPRI/M-plane', and a bottom purple line labeled 'MACSec CA'. The T-GM and T-TSC labels are positioned below their respective nodes. + +Figure 4.6.3.1.2.1-1 C-Plane and M-Plane protection based on MACsec in LLS-C1 topology + +As shown in the above figure, eCPRI/C-Plane and M-Plane traffic is protected by MACsec. It is recommended that PTP remains unprotected due to PTP over MACsec implementation challenges. PTP may use its own integrity security mechanism. However, if synchronization performance is guaranteed by any implementation, then MACsec as a security solution for PTP is not precluded in this topology. + +###### 4.6.3.1.2.2 MACsec in LLS-C2 topology running PTP G.8275.1 profile + +![Diagram of LLS-C2 topology showing MACsec protection between O-DU and O-RU.](d8b655421eaad89c286514e19d2c27f4_img.jpg) + +The diagram illustrates the LLS-C2 topology for MACsec protection. It shows a linear sequence of nodes: O-DU (T-GM), B1 (T-BC), B2 (T-BC), and O-RU (T-TSC). Red double-headed arrows above the nodes indicate 'Unprotected PTP over Eth session' between O-DU and B1, B1 and B2, and B2 and O-RU. A green double-headed arrow below the nodes, spanning from O-DU to O-RU, is labeled 'Protected eCPRI/M-plane' with the text 'Source MAC:O-DU/O-RU, Destination MAC: O-RU/O-DU' below it. A purple double-headed arrow at the bottom, also spanning from O-DU to O-RU, is labeled 'MACSec CA'. + +Diagram of LLS-C2 topology showing MACsec protection between O-DU and O-RU. + +Figure 4.6.3.1.2.2-1 C-Plane and M-Plane protection based on MACsec in LLS-C2 topology + +As shown in the above figure, eCPRI/C-Plane and M-Plane traffic is protected by MACsec End-to-End between O-DU and O-RU. Fronthaul Transport Network Equipment (TNE) such as B1 or B2 in the above figure does not participate in MACsec. PTP remains unprotected by MACsec since PTP over MACsec would require MACsec to be hop by hop instead of end to end which can lead to two challenges – MACsec in each TNE in Fronthaul can cause more latency per TNE for any kind of traffic including latency sensitive C/U-Plane traffic and also such hop-by-hop deployment might be difficult. So PTP over MACsec is not recommended. PTP may use its own integrated security mechanism. However, if synchronization performance is guaranteed by any implementation, then MACsec as a security solution for PTP is not precluded in this topology. + +###### 4.6.3.1.2.3 MACsec in LLS-C3 topology running PTP G.8275.1 profile + +![Diagram of LLS-C3 topology showing MACsec protection between O-DU and O-RU.](bc2e2981598b52002fba062d70e305da_img.jpg) + +The diagram illustrates the LLS-C3 topology for MACsec protection. It shows a linear sequence of nodes: O-DU (T-TSC), B1 (T-BC), B2 (T-BC), and O-RU (T-TSC). A T-GM node is positioned above B1. Red double-headed arrows indicate 'Unprotected PTP over Eth session' between O-DU and B1, B1 and B2, and B2 and O-RU. A vertical red double-headed arrow connects B1 and T-GM, also labeled 'Unprotected PTP over Eth session'. A green double-headed arrow below the nodes, spanning from O-DU to O-RU, is labeled 'Protected eCPRI/M-plane'. A purple double-headed arrow at the bottom, also spanning from O-DU to O-RU, is labeled 'MACSec CA'. + +Diagram of LLS-C3 topology showing MACsec protection between O-DU and O-RU. + +Figure 4.6.3.1.2.3-1 C-Plane and M-Plane protection based on MACsec in LLS-C3 topology + +In the case of LLS-C3 deployment all the discussions for LLS-C2 would also apply. + +##### 4.6.3.1.3 Deployment Considerations for Shared O-RU + +##### 4.6.3.1.3.1 Introduction + +The Shared O-RU is defined as an O-RU that is configured to support multiple O-DUs, allowing the O-RU to share its resources, such as carriers, among the connected O-DUs. The Shared O-RU supports two configuration modes: + +**SHARED-ORU-MULTI-ODU** refers to the configuration where a single O-RU is set up to operate with multiple O-DUs that belong to the same operator. + +**SHARED-ORU-MULTI-OPERATOR** refers to the configuration where a single O-RU is set up to operate with one or more O-DUs from one or more Shared Resource Operators (SROs). + +Each O-DU and Shared O-RU pair has uniquely configured transport parameters. O-DUs, whether from the same or different operators, shall connect to the Shared O-RU using existing CUS-Plane interface definitions and procedures. Consequently, the same security protection mechanisms that apply to a standard O-RU are also applicable. + +![Diagram illustrating the Shared O-RU Concept. Two O-DUs, O-DU #1 (Shared O-RU Host + SRO Role) and O-DU #2 (SRO Role), are connected to a central Shared O-RU. The connections are labeled 'C/U-Plane messages'.](5680c7b2028e4afdf581c566a2bea42c_img.jpg) + +``` + +graph TD + OD1["O-DU #1 +(Shared O-RU Host ++ SRO Role)"] + OD2["O-DU #2 +(SRO Role)"] + SORU["Shared O-RU"] + OD1 -- "C/U-Plane +messages" --- SORU + OD2 -- "C/U-Plane +messages" --- SORU + +``` + +Diagram illustrating the Shared O-RU Concept. Two O-DUs, O-DU #1 (Shared O-RU Host + SRO Role) and O-DU #2 (SRO Role), are connected to a central Shared O-RU. The connections are labeled 'C/U-Plane messages'. + +Figure 4.6.3.1.3.1-1 Shared O-RU Concept [i.5] + +###### 4.6.3.1.3.2 MACsec configuration for Shared O-RU. + +For MACsec enabling in a Shared O-RU, the Shared O-RU should support multiple secure connectivity associations to the O-DUs, with each association being independently configurable. This allows for separate management and security of each connection between the O-RU and the O-DUs, regardless of whether they belong to the same operator or different Shared Resource Operators (SROs). + +MACsec is essential for securing eCPRI C and U plane messages in a Shared O-RU setup, through encryption, integrity, and authentication. Deployment considerations include scenarios where all O-DUs under the Shared O-RU are collocated, as well as scenarios where the O-DUs are distributed across different data center locations. + +NOTE: Shared O-RU supports the M-Plane architecture model of hierarchical and hybrid models. The Shared O-RU Host uses a NETCONF client with "sudo" privileges, as defined in clause 6.5 of the M-Plane Specification[i.6], to configure the shared O-RU. Each Shared Resource Operator uses NETCONF clients with "carrier" privileges that have parallel M-Plane connections with the shared O-RU. The security controls for M-plane are defined in [i.6] and [i.20] and are not in scope within this document. + +###### 4.6.3.1.3.2.1 MACsec enabled at TNE1 at Cell site and TNE2 at the Central Site. + +In this configuration, MACsec is activated on the edge transport network elements located at both the cell site and central site. The O-RU sends unencrypted eCPRI (C/U-Plane) messages to TNE1, where they are encrypted and then transmitted over a secure channel to TNE2 at the central site. + +The MACsec solution proposal as described in clause 4.6.2 enables selective filtering of traffic requiring encryption in the Open Fronthaul network. + +This scenario is Zero Trust Architecture compliant from the Cell Site TNE1 to the central site TNE2. + +![Figure 4.6.3.1.3.2.1-1: Network diagram showing MACsec enabled at TNE. The Cell Site contains a Shared O-RU connected to TNE1 via C/U/S-Plane. TNE1 is connected to TNE2 via Open Front Haul (C/U/S-Plane). The Central Site contains TNE2 connected to O-DU#1 (Shared O-RU Host + SRO1) and O-DU#2 (SRO2) via C/U/S-Plane. A large red double-headed arrow labeled MACsec spans the Open Front Haul link.](e9e107abba57a605a98a843bd7277676_img.jpg) + +Figure 4.6.3.1.3.2.1-1: Network diagram showing MACsec enabled at TNE. The Cell Site contains a Shared O-RU connected to TNE1 via C/U/S-Plane. TNE1 is connected to TNE2 via Open Front Haul (C/U/S-Plane). The Central Site contains TNE2 connected to O-DU#1 (Shared O-RU Host + SRO1) and O-DU#2 (SRO2) via C/U/S-Plane. A large red double-headed arrow labeled MACsec spans the Open Front Haul link. + +Figure 4.6.3.1.3.2.1-1 MACsec enabled at TNE + +###### 4.6.3.1.3.2.2 MACsec enabled at Shared O-RU and the O-DUs. + +This option explores enabling MACsec at the Shared O-RU and O-DUs without requiring MACsec awareness in the transport network elements. The Shared O-RU should support more than one connectivity association and each connectivity association can be independently configured and managed for O-DU#1, O-DU#2. + +The MACsec solution proposal as described in clause 4.6.2 enables selective filtering of traffic requiring encryption in the Open Fronthaul network. + +This scenario is Zero Trust Architecture compliant from the Shared O-RU to the O-DUs. + +![Figure 4.6.3.1.3.2.2-1: Network diagram showing MACsec enabled at the Shared O-RU and the O-DUs. The architecture is identical to Figure 4.6.3.1.3.2.1-1, but with two large red double-headed arrows labeled MACsec-CA1 and MACsec-CA2 spanning the entire path from the Shared O-RU to the O-DUs, bypassing the TNEs and Open Front Haul.](2de9c3bf2b11d410793be432ad061699_img.jpg) + +Figure 4.6.3.1.3.2.2-1: Network diagram showing MACsec enabled at the Shared O-RU and the O-DUs. The architecture is identical to Figure 4.6.3.1.3.2.1-1, but with two large red double-headed arrows labeled MACsec-CA1 and MACsec-CA2 spanning the entire path from the Shared O-RU to the O-DUs, bypassing the TNEs and Open Front Haul. + +Figure 4.6.3.1.3.2.2-1 MACsec enabled at the Shared O-RU and the O-DUs + +###### 4.6.3.1.3.2.3 MACsec enabled at Shared O-RU and directly connected O-DUs. + +This option explores enabling MACsec at the Shared O-RU which is directly connected to the O-DUs either from single and/or multiple operators. + +The MACsec solution in clause 4.6.2 allows selective filtering of encrypted traffic in the Open Fronthaul network. Separate VLANs can be configured, with MACsec enabled on only one, and selective filtering applied at the base interface. + +This scenario is Zero Trust Architecture compliant from the Shared O-RU to the directly connected O-DUs. + +NOTE: O-RUs with two physical interfaces and each managed by different SROs not yet supported by M-plane specification [i.13]. + +![Figure 4.6.3.1.3.2.3-1: MACsec enabled at the Shared O-RU and the O-DUs. The diagram shows a Cell Site with a Shared O-RU connected to two O-DUs (O-DU#1 and O-DU#2) via OFH-C/U/S-Plane-CA-1 and OFH-C/U/S-Plane-CA-2. A large red arrow labeled MACsec spans the connection between the Shared O-RU and the O-DUs.](665e2d64c76197ebb7794dff78fe3e03_img.jpg) + +Figure 4.6.3.1.3.2.3-1: MACsec enabled at the Shared O-RU and the O-DUs. The diagram shows a Cell Site with a Shared O-RU connected to two O-DUs (O-DU#1 and O-DU#2) via OFH-C/U/S-Plane-CA-1 and OFH-C/U/S-Plane-CA-2. A large red arrow labeled MACsec spans the connection between the Shared O-RU and the O-DUs. + +Figure 4.6.3.1.3.2.3-1 MACsec enabled at the Shared O-RU and the O-DUs + +###### 4.6.3.1.3.2.4 MACsec enabled at Shared O-RU and directly connected TNE. + +This option explores enabling MACsec at the Shared O-RU and TNE at the Central site O-DUs, The Shared O-RU is directly connected to the TNE where the O-DUs are collocated either from single and/or multiple operators. + +The MACsec solution proposal as described in clause 4.6.2 enables selective filtering of traffic requiring encryption in the Open Fronthaul network. + +This scenario is Zero Trust Architecture compliant from the Shared O-RU to the TNE. + +![Figure 4.6.3.1.3.2.4-1: MACsec enabled at the Shared O-RU and the O-DUs. The diagram shows a Cell Site with a Shared O-RU connected to a Central Site via an Open Front Haul (OFH) cloud. The Central Site contains a TNE (Transport Network Element) connected to two O-DUs (O-DU#1 and O-DU#2) via C/U/S-Plane. A large red arrow labeled MACsec spans the connection between the Shared O-RU and the TNE.](bb558d2103eceb2abca81003e3e90939_img.jpg) + +Figure 4.6.3.1.3.2.4-1: MACsec enabled at the Shared O-RU and the O-DUs. The diagram shows a Cell Site with a Shared O-RU connected to a Central Site via an Open Front Haul (OFH) cloud. The Central Site contains a TNE (Transport Network Element) connected to two O-DUs (O-DU#1 and O-DU#2) via C/U/S-Plane. A large red arrow labeled MACsec spans the connection between the Shared O-RU and the TNE. + +Figure 4.6.3.1.3.2.4-1 MACsec enabled at the Shared O-RU and the O-DUs + +###### 4.6.3.1.3.2.5 MACsec enabled at TNES in a non-collocated O-DUs scenario + +This option explores the SHARED-ORU-MULTI-OPERATOR architecture where O-DUs are not collocated. In this configuration, MACsec is activated on the edge transport network elements located at both the cell site and central sites. + +The MACsec solution proposal as described in clause 4.6.2 enables selective filtering of traffic requiring encryption in the Open Fronthaul network. + +This scenario is Zero Trust Architecture compliant from the TNE1 at Cell Site to the TNE2 and TNE 3 at the Central site. + +![Figure 4.6.3.1.3.2.5-1: Network diagram showing MACsec enabled at TNEs in a non-collocated O-DU scenario. The Cell Site contains a Shared O-RU connected to TNE1 via C/U/S-Plane. Two Open Fronthaul clouds connect TNE1 to TNE2 and TNE3 respectively. Central Site-1 contains TNE2 connected to O-DU#1 (SOH+SRO1) via C/U/S-Plane. Central Site-2 contains TNE3 connected to O-DU#2 (SRO2) via C/U/S-Plane. Red arrows labeled MACsec indicate secure paths from TNE1 to TNE2 and TNE3. A red arrow labeled C/U-Plane indicates a path from TNE1 to Central Site-2.](858705c575cfd1586b518419f2d40c08_img.jpg) + +Figure 4.6.3.1.3.2.5-1: Network diagram showing MACsec enabled at TNEs in a non-collocated O-DU scenario. The Cell Site contains a Shared O-RU connected to TNE1 via C/U/S-Plane. Two Open Fronthaul clouds connect TNE1 to TNE2 and TNE3 respectively. Central Site-1 contains TNE2 connected to O-DU#1 (SOH+SRO1) via C/U/S-Plane. Central Site-2 contains TNE3 connected to O-DU#2 (SRO2) via C/U/S-Plane. Red arrows labeled MACsec indicate secure paths from TNE1 to TNE2 and TNE3. A red arrow labeled C/U-Plane indicates a path from TNE1 to Central Site-2. + +Figure 4.6.3.1.3.2.5-1 MACsec enabled at TNEs in a non-collocated O-DU scenarios + +###### 4.6.3.1.3.2.6 MACsec enabled at Shared O-RU and non-collocated O-DUs + +This configuration explores the scenario where this O-DUs are not collocated. In this configuration MACsec is enabled at the Shared O-RU and O-DUs, offering a secure communication pathway without requiring MACsec awareness in the transport network elements and is similar to the clause 4.6.3.1.2.2.2. The Shared O-RU will have two connectivity association towards the O-DUs. + +The MACsec solution proposal as described in clause 4.6.2 enables selective filtering of traffic requiring encryption in the Open Fronthaul network. + +This scenario is Zero Trust Architecture compliant from the Shared O-RUs at Cell Site to the ODU#1 and ODU#2 at the Central sites. + +![Figure 4.6.3.1.3.2.6-1: Network diagram showing MACsec enabled at Shared O-RU and non-collocated O-DUs. The Cell Site contains a Shared O-RU connected to TNE1 via C/U/S-Plane. Two Open Fronthaul clouds connect TNE1 to TNE2 and TNE3 respectively. Central Site-1 contains TNE2 connected to O-DU#1 (SOH+SRO1) via C/U/S-Plane. Central Site-2 contains TNE3 connected to O-DU#2 (SRO2) via C/U/S-Plane. Red arrows labeled MACsec-CA1 and MACsec-CA2 indicate secure paths from the Shared O-RU to O-DU#1 and O-DU#2 respectively.](9bd92627fea607c8b9c72ef1d73d487c_img.jpg) + +Figure 4.6.3.1.3.2.6-1: Network diagram showing MACsec enabled at Shared O-RU and non-collocated O-DUs. The Cell Site contains a Shared O-RU connected to TNE1 via C/U/S-Plane. Two Open Fronthaul clouds connect TNE1 to TNE2 and TNE3 respectively. Central Site-1 contains TNE2 connected to O-DU#1 (SOH+SRO1) via C/U/S-Plane. Central Site-2 contains TNE3 connected to O-DU#2 (SRO2) via C/U/S-Plane. Red arrows labeled MACsec-CA1 and MACsec-CA2 indicate secure paths from the Shared O-RU to O-DU#1 and O-DU#2 respectively. + +Figure 4.6.3.1.3.2.6-1 MACsec enabled at Shared O-RU and non collocated O-DUs + +###### 4.6.3.1.3.2.7 MACsec enabled at Shared O-RU directly connected to TNEs in non-collocated O-DUs scenario. + +In this configuration the Shared O-RU is directly connected to the TNE's in a non-collocated O-DU scenario. MACsec is enabled at the Shared O-RU and TNE's. The Shared O-RU will have two connectivity association towards the TNEs at the central sites. + +The MACsec solution proposal as described in clause 4.6.2 enables selective filtering of traffic requiring encryption in the Open Fronthaul network. + +This scenario is Zero Trust Architecture compliant from the Shared O-RUs at Cell Site to the TNE1 and TNE 2 at the Central sites + +![Diagram illustrating MACsec enabled at Shared O-RU directly connected to TNEs in non-collocated O-DUs scenario. The diagram shows a Cell Site on the left containing a Shared O-RU. Two Open Fronthaul clouds connect the Shared O-RU to Central Site-1 and Central Site-2. Central Site-1 contains TNE1 and O-DU#1 (SRO1). Central Site-2 contains TNE2 and O-DU#2 (SRO2). Red arrows labeled MACsec-CA1 and MACsec-CA2 point from the Shared O-RU to TNE1 and TNE2 respectively. Bidirectional arrows labeled C/U/S-Plane connect the Shared O-RU to TNE1 and TNE2. Bidirectional arrows labeled C/U/S-Plane connect TNE1 to O-DU#1 and TNE2 to O-DU#2.](c097f2a742c0fa76286bc71e26a63dae_img.jpg) + +Diagram illustrating MACsec enabled at Shared O-RU directly connected to TNEs in non-collocated O-DUs scenario. The diagram shows a Cell Site on the left containing a Shared O-RU. Two Open Fronthaul clouds connect the Shared O-RU to Central Site-1 and Central Site-2. Central Site-1 contains TNE1 and O-DU#1 (SRO1). Central Site-2 contains TNE2 and O-DU#2 (SRO2). Red arrows labeled MACsec-CA1 and MACsec-CA2 point from the Shared O-RU to TNE1 and TNE2 respectively. Bidirectional arrows labeled C/U/S-Plane connect the Shared O-RU to TNE1 and TNE2. Bidirectional arrows labeled C/U/S-Plane connect TNE1 to O-DU#1 and TNE2 to O-DU#2. + +Figure 4.6.3.1.3.2.7-1 MACsec enabled at Shared O-RU directly connected to TNEs in non-collocated O-DUs scenario + +###### 4.6.3.1.3.2.8 MACsec enabled at the Shared O-RU and the O-DUs for SHARED-ORU-MULTI-OPERATOR Configuration in Hybrid mode + +The option explores the Shared O-RU and multiple O-DUs for SHARED-ORU-MULTI-OPERATOR configuration in a hybrid mode. The Shared O-RU Host SMO manages the M-Plane for the Shared O-RU and the security controls for the M-Plane management traffic has been specified in the O-RAN Management Plane Specification [i.6] and Security Requirements and Controls Specification [i.20] and is not in scope in this study. In this configuration MACsec is enabled at the Shared O-RU and ODU's at the central site offering a secured connectivity association between two endpoints. + +The MACsec solution proposal as described in clause 4.6.2 enables selective filtering of traffic requiring encryption in the Open Fronthaul network. + +This scenario is Zero Trust Architecture compliant from the Shared O-RUs at Cell Site to the O-DUs at the Central site + +NOTE: In hybrid mode, the shared O-RU should have a mechanism to trust the MACsec parameters configured by the Shared O-RU host SMO to establish secure connectivity with the SROs . + +![Network architecture diagram for MACsec enabled at the Shared O-RU and the O-DUs for SHARED-ORU-MULTI-OPERATOR Configuration in Hybrid mode.](06fc01b168195375d2ceb906fa336e88_img.jpg) + +The diagram illustrates a network architecture for MACsec enabled at the Shared O-RU and the O-DUs for SHARED-ORU-MULTI-OPERATOR Configuration in Hybrid mode. The architecture is divided into two main sites: the Cell Site and the Central Site. + +**Cell Site:** Contains a Shared O-RU (orange box) and TNE1 (purple circle). The Shared O-RU is connected to TNE1 via a C/U/S-Plane interface. The Shared O-RU is also connected to the Shared O-RU Host SMO (yellow box) via an M-Plane interface. + +**Central Site:** Contains TNE2 (purple circle), O-DU#1 (SRO1) (blue box), and O-DU#2 (SRO2) (blue box). TNE2 is connected to O-DU#1 and O-DU#2 via C/U/S-Plane interfaces. TNE2 is also connected to the Shared O-RU Host SMO via an O1 interface. + +**Open Front Haul:** A cloud icon representing the Open Front Haul connects TNE1 and TNE2 via a C/U/S-Plane interface. + +**MACsec Configuration:** A large red arrow at the bottom indicates the MACsec configuration. It is labeled MACsec-CA1 and MACsec-CA2, indicating that MACsec is enabled at the Shared O-RU and the O-DUs. + +Network architecture diagram for MACsec enabled at the Shared O-RU and the O-DUs for SHARED-ORU-MULTI-OPERATOR Configuration in Hybrid mode. + +Figure 4.6.3.1.3.2.8-1 MACsec enabled at the Shared O-RU and the O-DUs for SHARED-ORU-MULTI-OPERATOR Configuration in Hybrid mode. + +O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00 + +# Annex A (informative): Port-based authentication using 802.1x and 802.1AR Secure Device Identity + +![](c483715abe91185948e2fe0108e05c6e_img.jpg) + +``` + +sequenceDiagram + autonumber + participant EAP as EAP Server + participant CA as Certificate Enrollment System + participant L3_Prov as L3/DHCP for provisioning segment + participant L3_Oper as L3/DHCP for operational segment + participant PAE as IEEE 802.1x Port Authenticating Entity + participant RU as IEEE 802.1x enabled O-RU + + Note over PAE: Port in unauthorized state - blocks all traffic other than EAPOL traffic + Note over RU: Manufacturer 802.1AR Initial DevID (iDevID) Certificate Installed + + rect rgb(240, 240, 240) + Note over EAP, RU: Initial limited-access when authenticated using supplier certificate + RU->>PAE: EAPoL Start + PAE->>RU: EAP-Request/Identity + RU->>PAE: EAP-Response/Identity (from iDevID Certificate Subject DN) + PAE->>EAP: RADIUS-Access-Request or Diameter-EAP-Request (EAP-Response) + EAP->>PAE: RADIUS-Access-Challenge or Diameter-EAP-Answer (EAP-Request) + PAE->>RU: EAPoL (EAP-Request) + Note over EAP, RU: EAP Dialogue Continues using iDevID Certificate + EAP->>PAE: RADIUS-Access-Accept or Diameter-EAP-Answer (EAP-Success) +Including security policy, e.g., Provisioning/Enrollment VLAN + PAE->>RU: EAP-Success + Note over PAE: Set port to authorized state. +Assign port to provided security policy, e.g., Provisioning/Enrollment VLAN + end + + rect rgb(230, 240, 250) + Note over EAP, RU: Enrollment into operator PKI + RU->>L3_Prov: DHCP Discover/Router Solicitation + Note over L3_Prov, RU: IP Address Allocation Completes, e.g., including DHCP Opt43/DHCPv6 Opt17 for CA/RA Server discovery + RU->>CA: CMPv2 Initialization or EST Request + Note over CA, RU: Certificate Enrollment Completes & Provision of Local DeviceID certificate + Note over RU: Install LDevID Certificate + end + + rect rgb(240, 240, 240) + Note over EAP, RU: Subsequent full operational access when authenticated using operator installed certificate + Note over RU: re-start of O-RU triggers interface re-initialization + Note over PAE: Interface re-initialization: resets port to unauthorized state - blocks all traffic other than EAPOL traffic + RU->>PAE: EAPoL Start + PAE->>RU: EAP-Request/Identity + RU->>PAE: EAP-Response/Identity (from LDevID certificate Subject DN) + PAE->>EAP: RADIUS-Access-Request or Diameter-EAP-Request (EAP-Response) + EAP->>PAE: RADIUS-Access-Challenge or Diameter-EAP-Answer (EAP-Request) + PAE->>RU: EAPoL (EAP-Request) + Note over EAP, RU: EAP Dialogue Continues using Operator Installed LDevID Certificate + EAP->>PAE: RADIUS-Access-Accept or Diameter-EAP-Answer (EAP-Success) +Including security policy, e.g., Operational VLAN + PAE->>RU: EAP-Success + Note over PAE: Set port to authorized state. +Assign port to provided security policy, e.g., Operational VLAN + RU->>L3_Oper: DHCP Discover/Router Solicitation + Note over L3_Oper, RU: IP Address Allocation Completes, e.g., including DHCP Opt43/DHCPv6 Opt17 for NECTONF Client and/or Event-Collector discovery + Note over RU: Normal O-RU M-Plane start up continues + end + +``` + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification + +# Annex B (informative): Deployment consideration for encryption of C Plane messages in an Open Fronthaul network + +The O-RAN 7.2x is a split 7 “Low Level Split” (LLS) that runs between the O-RU and the O-DU. In the O-RAN architecture, service providers possess the flexibility to determine the placement of network components. Deployment scenarios may involve collocating O-RUs and O-DUs at the cell site or placing O-RUs and O-DUs in two distinct geographical locations. The deployment scenarios drive the need for encryption of C-Plane over an Open Fronthaul network. + +## Deployment Scenario 1: Collocated O-RU and O-DU at Cell Site + +In this deployment scenario the O-RU and O-DU are collocated at the cell-site in an LLS-C1 or LLS-C2 topology. The fronthaul network's entire infrastructure is confined within the secure perimeter of the cell site, the risks associated with data interception or tampering are substantially reduced as the adversary would need physical access to the cell site location. By considering the network architecture, and maintaining robust cell-site security, stakeholders can create a resilient fronthaul network infrastructure that effectively address external threats. + +Although cell-site physical security prevents external threat, but it does not prevent an insider attack. The risk of insider attacks necessitates additional measures, such as the encryption of C-Plane messages, aligned with the principles of Zero Trust Architecture. + +The need for encrypting C-Plane messages in this deployment scenario may be based on the operator choice of operational overload and network architecture, cell-site security. + +![Diagram of Deployment Scenario 1: Collocated O-RU and O-DU at Cell Site. The diagram shows a dashed box labeled 'Cell Site' containing an 'O-RU' (orange rectangle) and an 'O-DU' (blue rectangle) connected by a bidirectional arrow labeled 'Open Front Haul'. A bidirectional arrow labeled 'Mid-haul Network' connects the 'O-DU' to an 'O-CU' (green rectangle) located in a dashed box labeled 'Centralized Site'.](daf98618bc0520ce3151fa27e8e714dc_img.jpg) + +Diagram of Deployment Scenario 1: Collocated O-RU and O-DU at Cell Site. The diagram shows a dashed box labeled 'Cell Site' containing an 'O-RU' (orange rectangle) and an 'O-DU' (blue rectangle) connected by a bidirectional arrow labeled 'Open Front Haul'. A bidirectional arrow labeled 'Mid-haul Network' connects the 'O-DU' to an 'O-CU' (green rectangle) located in a dashed box labeled 'Centralized Site'. + +Fig B-1: Collocated O-DU and O-RU connected directly at Cell Site. + +![Diagram of Deployment Scenario 2: O-RU at Cell site and O-DU and O-CU at the Central site. The diagram shows a dashed box labeled 'Cell Site' containing an 'O-RU' (orange rectangle) and an 'O-DU' (blue rectangle) both connected to a central 'Open Front Haul' (grey oval). The 'Open Front Haul' is connected to a 'TNE' (purple circle) within the 'Cell Site'. A bidirectional arrow labeled 'Mid-haul Network' connects this 'TNE' to another 'TNE' (purple circle) in a dashed box labeled 'Centralized Site'. The 'Centralized Site' also contains an 'O-CU' (green rectangle) connected to the 'TNE'.](9dff38abf847e340d6b506ad79122d9b_img.jpg) + +Diagram of Deployment Scenario 2: O-RU at Cell site and O-DU and O-CU at the Central site. The diagram shows a dashed box labeled 'Cell Site' containing an 'O-RU' (orange rectangle) and an 'O-DU' (blue rectangle) both connected to a central 'Open Front Haul' (grey oval). The 'Open Front Haul' is connected to a 'TNE' (purple circle) within the 'Cell Site'. A bidirectional arrow labeled 'Mid-haul Network' connects this 'TNE' to another 'TNE' (purple circle) in a dashed box labeled 'Centralized Site'. The 'Centralized Site' also contains an 'O-CU' (green rectangle) connected to the 'TNE'. + +Fig 1-2: Collocated O-DU and O-RU connected via TNE at Cell Site. + +## Deployment Scenario 2: O-RU at Cell site and O-DU and O-CU at the Central site + +In this deployment strategy, the O-RU is placed exclusively at the cell site, while the O-DU and O-CU is placed at a centralized location. The traffic from O-RU is transported over a switched fronthaul network. + +The Fronthaul network consists of one or more number of switches and routers. The network path between the O-DU and O-RU are prone to threats as defined in clause 2.3.1. + +Encryption for C-plane messages is recommended for this deployment scenario. + +![Diagram of O-RAN architecture showing O-RU at Cell site and O-DU/O-CU at Centralized Site, connected via Open Front Haul, with a red arrow indicating C-plane message encryption.](5461067420bde421ee2402a3e081c6bc_img.jpg) + +``` + +graph LR + subgraph Cell_Site [Cell Site] + ORU[O-RU] <--> TNE1((TNE)) + end + subgraph Centralized_Site [Centralized Site] + TNE2((TNE)) <--> ODU[O-DU] + ODU <--> OCU[O-CU] + end + TNE1 <-->|Open Front Haul| TNE2 + direction LR + Cell_Site <-->|Encrypt C-Plane Messages| Centralized_Site + +``` + +The diagram illustrates the O-RAN architecture. On the left, the **Cell Site** contains an **O-RU** (orange rectangle) and a **TNE** (purple circle). On the right, the **Centralized Site** contains a **TNE** (purple circle), an **O-DU** (blue rectangle), and an **O-CU** (green rectangle). The **O-RU** and **TNE** at the Cell Site are connected by a bidirectional arrow. The **TNE** and **O-DU** at the Centralized Site are connected by a bidirectional arrow, and the **O-DU** and **O-CU** are also connected by a bidirectional arrow. A cloud labeled **Open Front Haul** connects the **TNE** at the Cell Site to the **TNE** at the Centralized Site. A large red double-headed arrow spans the entire width of the diagram, labeled **Encrypt C-Plane Messages**, indicating the security requirement for the C-plane traffic across the entire network path. + +Diagram of O-RAN architecture showing O-RU at Cell site and O-DU/O-CU at Centralized Site, connected via Open Front Haul, with a red arrow indicating C-plane message encryption. + +Fig 2: O-RU at Cell site O-DU and O-CU at the Central site + +# Annex C: Change history/Change request (history) + +| Date | Revision | Description | +|------------|-----------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.11.27 | R004-v03.00 | Published as TR.O-R004-v03.00 | +| 2024.11.27 | R004-v03.00 | Ericsson: Updates to security analysis of C-plane | +| 2024.11.27 | R004-v03.00 | Ericsson: MACsec for Open Fronthaul CUS-Plane | +| 2024.11.27 | R004-v03.00 | Rakuten Symphony: Changes in clause for 4.6 to better align the TR for the Deployment consideration for MACsec clause | +| 2024.11.27 | R004-v03.00 | Rakuten Symphony: MACsec for Shared O-RU configuration | +| 2024.11.27 | R004-v03.00 | Rakuten Symphony: Changes in Introduction clause for 4.6.3 to include the deployment consideration for Shared O-RU | +| 2024.07.25 | R004-v02.00 | Published as TR.O-R004-v02.00 | +| 2024-07-10 | R004-v02.00 | Rakuten Symphony: Clause number update based on the CR0067 | +| 2024-07-10 | R004-v02.00 | Rakuten Symphony: MACsec encryption modes and restructuring of clauses | +| 2024-07-10 | R004-v02.00 | Ericsson: Technical clarifications for Solution #2 | +| 2024-07-10 | R004-v02.00 | Ericsson: Inclusive Language | +| 2024-07-10 | R004-v02.00 | Ericsson: MACsec for Open Fronthaul CUS-Plane | +| 2024-07-10 | R004-v02.00 | NEC and Rakuten Symphony: Correction of a) Potential Security Requirements (Clause 4.2.2.1.4) of Key Issue #1 related to Security for S-Plane, and b) Potential Security Requirements (Clause 4.5.1.1.4) of Key issue #1 related to Security for Fronthaul Ethernet L1 physical layer interface. Addition of Figures to Clause 4.2.2.1.1 to indicate fake ANNOUNCE message attack scenarios. | +| 2024-07-10 | R004-v02.00 | NEC and Rakuten Symphony: Correction of Key Issue of S-Plane security under clause 4.2.2.2, Consistent use of "Grandmaster" | +| 2024-07-10 | R004-v02.00 | Rakuten Symphony and NEC: Correction of Key Issues of S-Plane security under clauses 4.2.2.3 and 4.2.2.4 | +| 2024.03.30 | R004-v01.00 | Published as TR.O-R004-v01.00 | +| 2024-03-30 | R004-v01.00 | Rakuten Symphony and Analog Devices: Deployment considerations for encryption of C-plane messages | +| 2024-03-30 | R004-v01.00 | Rakuten Symphony: Update S-plane security clause in the TR with solutions and evaluations | +| 2024-03-30 | R004-v01.00 | Nokia and Rakuten Symphony: Solution on PTP integrated security mechanism | +| 2024-03-30 | R004-v01.00 | Rakuten Symphony and Analog Devices: Update clause 4.6.4 MACsec solution for Open Fronthaul | +| 2024-03-30 | R004-v01.00 | Rakuten Symphony and Nokia : MACsec as a security solution for protecting U-Plane messages | +| 2024-03-30 | R004-v01.00 | Nokia: WAN mode | +| 2024-03-30 | R004-v01.00 | Nokia and Rakuten Symphony: Solution on PTP integrated security mechanism announce only | +| 2023-10-25 | R003-v01.00 | Nokia and Analog Devices contribution on KI for C-Plane Security, Nokia contribution on KI for U-Plane Security, Rakuten Symphony contribution for KI on C-Plane Security | +| 2021-07-15 | July 15 th
    weekly
    FHSec
    meeting | Keysight contribution on MACsec, AltioStar contributions on S-Plane key issues and minor reformatting | +| | | | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/050823a1415d4fd33a5c117e7b4adeef_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/050823a1415d4fd33a5c117e7b4adeef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3bfb769e7c1894bdf9532dfea918f9a79f77c3aa --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/050823a1415d4fd33a5c117e7b4adeef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:21386a7520fcaa50a5744cb117bc6bccaee5ed81a31e3bedd5fcde1d7694bc07 +size 4198 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/0961ebce1f0226fd25d2239ac365f2a2_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/0961ebce1f0226fd25d2239ac365f2a2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1bd830fbbc53b287783950fa9c7c681aa81e7b62 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/0961ebce1f0226fd25d2239ac365f2a2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e868299fcbc061d1bb48066848d82063e767ea6a8e07c8c34f1a1e989730febd +size 4276 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/14471e67a8fcfe73ad67b374c227060a_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/14471e67a8fcfe73ad67b374c227060a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0086dbc4461eeb33f918dd0548f4625c7e8e1c85 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/14471e67a8fcfe73ad67b374c227060a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:82924768524f7aee162a2eaa9268192963678ef9047c850db51b624d2e006ab4 +size 4295 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/387f912751a6b3896c8a6e31cde4bd38_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/387f912751a6b3896c8a6e31cde4bd38_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8053ffea291c9df0c85ed5d3cdf304f1fd81a93c --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/387f912751a6b3896c8a6e31cde4bd38_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:42d1eca217282525313b5e952137823fccb8038f3d17fae11a129f2d7104830c +size 4195 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/3f56e44b74ab838f75b33171ab1f1257_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/3f56e44b74ab838f75b33171ab1f1257_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..924b694b4269f352bfa78c5c36be0e4fe0731fee --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/3f56e44b74ab838f75b33171ab1f1257_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dcbc54d9905cc9118421e853b275644f41158b8101ad048d939b8ffe26c215f5 +size 4075 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/4726613a5052b2673468264a41fbbf15_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/4726613a5052b2673468264a41fbbf15_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f86dbbe5b5c13cf8bf7daa6eedf7f058697ce2cb --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/4726613a5052b2673468264a41fbbf15_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d8cd1b75f6df8db957c6648f4508b3ea5a75aa8e299c0be51e33059a799f76c3 +size 4254 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/5f40703e176848f5c705a74cb9ed0731_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/5f40703e176848f5c705a74cb9ed0731_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..267b4f3dc4cbbc643c70104d02f9ab390f1fd0b5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/5f40703e176848f5c705a74cb9ed0731_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5e73c90b56ad9e2d092833245fad09e77fd7abffaadf6187d20b17349a8ac6da +size 4047 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/88034a31d26b933954218c538f6f899a_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/88034a31d26b933954218c538f6f899a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a4442730987c3c118129047615b1466f0f7c3875 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/88034a31d26b933954218c538f6f899a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8a89b0024927d05035dcb882a62cb16fffdf61afb5472bf2bf1ef9f2e89b8ec3 +size 4227 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/8f1e80bb3047ef5e53da06ca6c5f5eef_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/8f1e80bb3047ef5e53da06ca6c5f5eef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..844a4a08c1fc5d768fdddcf7417f8e4c87fd4656 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/8f1e80bb3047ef5e53da06ca6c5f5eef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:171e41cf018d817ecb807501c7e06136aafe5412d93e4add967c2bc3f6ac3810 +size 4200 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/b4f369b26eaa2faf4fe579431b03cb0c_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/b4f369b26eaa2faf4fe579431b03cb0c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0ef15d662e0102038dfde5bec07de53854cdf17d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/b4f369b26eaa2faf4fe579431b03cb0c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:90a20dd2e6bfca0235977809faf461e351856ab4f9d578fb305d87b66cdf024e +size 4200 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/d82e1ea45beac32d864c8b754723de52_img.jpg b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/d82e1ea45beac32d864c8b754723de52_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8f1d6cab924a14d89ecb8f7cade2aa55793d7c04 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/d82e1ea45beac32d864c8b754723de52_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9b81cb494a2f48ef04637c139ad7c4bbbdb239e7aec9156f529659588aae7ad +size 4044 diff --git a/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/raw.md b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..0c68823ef785864d98b6261e157accc8ce4fc186 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00/raw.md @@ -0,0 +1,475 @@ + + +# --- **O-RAN Working Group 11 (WG11)****Study on O-RU Centralized User Management** + +# --- Contents + +| | | +|---------------------------------------------------------------------------------------------------------------|----| +| Foreword ..... | 5 | +| Modal verbs terminology ..... | 5 | +| Introduction ..... | 5 | +| 1 Scope ..... | 6 | +| 2 References ..... | 7 | +| 2.1 Informative references ..... | 7 | +| 3 Definitions and Abbreviations ..... | 8 | +| 3.1 Terms ..... | 8 | +| 3.2 Definitions ..... | 8 | +| 3.3 Abbreviations ..... | 8 | +| 4 Background ..... | 9 | +| 4.1 Netconf Access Control ..... | 9 | +| 4.2 Software and Configuration Server (SCS) ..... | 9 | +| 5 Key Issues ..... | 10 | +| 5.1 Key Issue #1: Default account in O-RU ..... | 10 | +| 5.1.1 Key issue detail ..... | 10 | +| 5.1.2 Security threats ..... | 10 | +| 5.1.3 Potential security requirements ..... | 10 | +| 5.2 Key Issue #2: Default account get sudo role ..... | 10 | +| 5.2.1 Key issue detail ..... | 10 | +| 5.2.2 Security threats ..... | 10 | +| 5.2.3 Potential security requirements ..... | 11 | +| 5.3 Key Issue #3: The O-RU controller must keep track of locally defined users in each managed O-RU ..... | 11 | +| 5.3.1 Key issue detail ..... | 11 | +| 5.3.2 Security threats ..... | 11 | +| 5.3.3 Potential security requirements ..... | 11 | +| 5.4 Key Issue #4: How to get initial configuration to Central Server? ..... | 11 | +| 5.4.1 Key issue detail ..... | 11 | +| 5.4.2 Security threats ..... | 12 | +| 5.4.3 Potential security requirements ..... | 12 | +| 5.5 Key Issue #5: How does the O-RU connect securely to the Central Server? ..... | 12 | +| 5.5.1 Key issue detail ..... | 12 | +| 5.5.2 Security threats ..... | 12 | +| 5.5.3 Potential security requirements ..... | 12 | +| 5.6 Key Issue #6: Availability of the centralized user management server for the O-RUs ..... | 12 | +| 5.6.1 Key issue detail ..... | 12 | +| 5.6.2 Security threats ..... | 13 | +| 5.6.3 Potential security requirements ..... | 13 | +| 5.7 Key Issue #7: Categorisation of users that need to centrally and locally managed ..... | 13 | +| 5.7.1 Key issue detail ..... | 13 | +| 5.7.2 Security threats ..... | 13 | +| 5.7.3 Potential security requirements ..... | 13 | +| 5.8 Key Issue #8: Fetching initial security configuration data from a Software and Configuration Server ..... | 14 | +| 5.8.1 Key issue detail ..... | 14 | +| 5.8.2 Security threats ..... | 14 | +| 5.8.3 Potential security requirements ..... | 14 | +| 5.9 Key Issue #9: Secure transport to the centralized authentication server ..... | 14 | +| 5.9.1 Key issue detail ..... | 14 | +| 5.9.2 Security threats ..... | 14 | +| 5.9.3 Potential security requirements ..... | 14 | +| 5.10 Key Issue #10: Secure storage of O-RU credentials ..... | 15 | +| 5.10.1 Key issue detail ..... | 15 | +| 5.10.2 Security threats ..... | 15 | + +| | | | +|--------|------------------------------------------------|----| +| 5.10.3 | Potential security requirements ..... | 15 | +| 6 | Mitigations and Solutions ..... | 16 | +| 6.1 | Key Issue Analysis ..... | 16 | +| 6.2 | Solution #1: Centralized User Management ..... | 16 | +| 6.3 | Solution 2#: Initial Provisioning ..... | 16 | +| 6.4 | Solution #3 High Availability ..... | 16 | +| 7 | Conclusions ..... | 18 | +| 7.1 | Key Issue Solution Mapping ..... | 18 | +| Annex: | Change history/Change request (history) ..... | 19 | + +# Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- Introduction + +Current M-Plane specification mandates role-based access control with local user management. This implies that the Netconf Controller must keep track of locally defined users in each managed O-RU. It also means that some default behavior must be applied during installation of an O-RU, e.g. default users pre-defined by vendor for SSH and first trusted user connecting over TLS is given "sudo" role. + +In this technical report key security issues due to locally defined users in each managed O-RU are analyzed. The option of using a centralized user management is also evaluated, and solutions proposed along with the necessary security requirements. + +# 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document specifies the outcome of the study on O-RU Centralized User Management performed by the O-RAN Security Work Group (WG11). + +# 2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18, or the latest 3GPP release prior to Release 18 that includes that document. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [i.1] O-RAN ALLIANCE TS, “O-RAN Security Requirements and Controls Specifications” +- [i.2] O-RAN ALLIANCE TS, “O-RAN Management Plane Specification” +- [i.3] 3GPP TS 28.314: "Management and orchestration; Plug and Connect; Concepts and requirements". +- [i.4] 3GPP TS 28.315: "Management and orchestration; Plug and Connect; Procedure flows". +- [i.5] 3GPP TS 28.316: "Management and orchestration; Plug and Connect; Data formats". +- [i.6] O-RAN ALLIANCE TR, “O-RAN Security Threat Modeling and Risk Assessment +- [i.7] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. +- [i.8] 3GPP TS 33.117: "Catalogue of general security assurance requirements" +- [i.9] 3GPP TS 28.314: "Management and orchestration; Plug and connect; Concepts and requirements” +- [i.10] 3GPP TS 28.315: "Management and orchestration; Plug and connect; Procedure flows” + +# 3 Definitions and Abbreviations + +## 3.1 Terms + +For the purposes of the present document, no new terms are used. + +## 3.2 Definitions + +For the purposes of the present document, no new definitions are defined. + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [i.1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [i.7]. + +| | | +|------|-----------------------------------| +| AAS | Active Antenna System | +| eNB | e NodeB (applies to LTE) | +| gNB | g NodeB (applies to NR) | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| SCS | Software and Configuration Server | + +# 4 Background + +## 4.1 Netconf Access Control + +Netconf access control is defined in the WG4 M-Plane Specification [i.2] to be used in the O-RU, but only with local user management configuration in each O-RU. + +Netconf access control is also used on the O1 interface. The WG11 Security Requirements and Controls Specification [i.1] defines, for O1 entities, that (REQ-NAC-FUN-9): Netconf endpoints SHALL support external user to group mapping via at least one of the following protocols: LDAP with StartTLS, OAuth 2.0, RADIUS with EAP, and TACACS/TACACS+. + +## 4.2 Software and Configuration Server (SCS) + +The 3GPP TS 28.314 [i.3] and TS 28.315 [i.4] describes the SCS as an entity and how it can be used in a Plug and Connect use case to provide initial configuration to a Network Element. The O-RU can be seen as a Network Element that during the provisioning needs to get configuration and find an O-RU controller. + +The 3GPP TS 28.316 [i.5] describes how a Network Element can get the address to an SCS from a DHCP server. + +The WG4 M-Plane Specification [i.2] clause on “Start-up installation” currently does not include the use of an SCS. + +# 5 Key Issues + +This clause details the key issues identified for security aspects related to user management in the O-RU. + +## 5.1 Key Issue #1: Default account in O-RU + +### 5.1.1 Key issue detail + +Current M-plane specification [i.2] requires a vendor specific default account. Default accounts should be avoided if possible. + +The 3GPP TS 33.117 [i.8] section 4.2.3.4.2.2 states that predefined accounts shall be deleted or disabled. *“Should this measure not be possible the accounts shall be locked for remote login”*. + +### 5.1.2 Security threats + +- An attacker can log on to the O-RU in these cases: The vendor defined default account (username/password) is leaked. +- Any entity that is connecting using an accepted certificate using + - any operator-signed certificate verified by an installed trust anchor or + - any certificate if the enrollment failed and the O-RU supports the optional feature of using its pre-installed vendor-signed certificate for setting up mTLS connections to its O-RU Controller(s) (see [i.2], clause 6.2.6.3), as in this case the O-RU does not have an installed trust anchor. + +An attacker can use a successful log-on to connect to the O-RU before the connection to the O-RU controller is established. New accounts can be created. + +If the default account is not being disabled, it can be used to connect and modify existing configuration. + +### 5.1.3 Potential security requirements + +To mitigate the threat of an attacker using a default account to create additional accounts, the O-RU controller can verify that no unwanted accounts exist. This can be done every time when the O-RU Controller connects to an O-RU by comparing the O-RU user account configuration with the planned settings. An alternative is to avoid using a default account and rely on centralized user management during provisioning. + +## 5.2 Key Issue #2: Default account get sudo role + +### 5.2.1 Key issue detail + +Current M-plane specification requires that when first connection is made, the first (i.e. default) user get sudo role by default. Default accounts should be avoided if possible. + +### 5.2.2 Security threats + +The security threats identified with first connected user getting sudo role: + +An Attacker can connect using + +- any operator-signed certificate verified by an installed trust anchor or +- any certificate if the enrollment failed and the O-RU supports the optional feature of using its pre-installed vendor-signed certificate for setting up mTLS connections to its O-RU Controller(s) (see [i.2], clause 6.2.6.3), as in this case the O-RU does not have an installed trust anchor or +- a leaked default username/password + +will get “sudo” role. This can be used to connect to the O-RU before the connection to the O-RU controller is established. New accounts can be created. + +If the default account is not disabled, it can also be used after the connection to the O-RU controller is established to connect and modify existing configuration. + +### 5.2.3 Potential security requirements + +To mitigate the threat of an attacker using a default account, get “sudo” role and creates additional accounts, the O-RU controller can verify that no unwanted accounts exist. An alternative is to avoid using a default account and rely on centralized user management during provisioning. + +## 5.3 Key Issue #3: The O-RU controller must keep track of locally defined users in each managed O-RU + +### 5.3.1 Key issue detail + +Current M-plane specification defines role-based access control configured in each O-RU. Allowing for centralized user management would simplify management. + +### 5.3.2 Security threats + +The security threats identified with only local user management in O-RU, configured by the O-RU controller: + +- If the same user configuration is used in all O-RUs, any O-RU controller can connect to any O-RU. Changes will have to be performed on every O-RU. + +### 5.3.3 Potential security requirements + +To simplify management a centralized user management system can be used. + +## 5.4 Key Issue #4: How to get initial configuration to Central Server? + +### 5.4.1 Key issue detail + +When the O-RU is started for the first time, it will not have any operator specific configuration on how to connect to the central server. To use centralized user management this configuration is required. + +### 5.4.2 Security threats + +The security threats identified with the O-RU not having any operator specific configuration to use centralized user management: + +- If the O-RU does not know the address to the Central AA server (e.g. LDAP) it will revert to the use of locally defined users, i.e. issue 1-3 + +### 5.4.3 Potential security requirements + +The O-RU can get this data from one of the entities that it connects to during provisioning, i.e. DHCP, DNS and RA/CA, or from a new entity, e.g. SCS. + +## 5.5 Key Issue #5: How does the O-RU connect securely to the Central Server? + +### 5.5.1 Key issue detail + +The O-RU must have options to connect securely to the central server. + +### 5.5.2 Security threats + +The security threats identified with O-RU not having a secure connection to the centralized user management server: + +- Without a secure connection, the Central AA server (e.g. LDAP) can be fake +- Without a secure connection, the transferred response from the central AA server can be tampered + +### 5.5.3 Potential security requirements + +The connection to the centralized server should be authenticated and should be confidentiality and integrity protected. + +## 5.6 Key Issue #6: Availability of the centralized user management server for the O-RUs + +### 5.6.1 Key issue detail + +The centralized user management server should be available at all times. Hence the need to cover the below aspects + +- Overloading of centralized server + - Number of RUs connected to the server + - Frequency of making Authentication and Authorization calls + - Number of users that are managed centrally for the O-RU +- Network connectivity + - Connectivity loss between the O-RU and centralized server +- SW/HW failure of centralized server + +- The centralized server might be unavailable due to a software or HW failure and hence needs to be highly available + +### 5.6.2 Security threats + +- Slow response of the centralized server due to overloading +- Unavailability of the centralized server due to overloading +- No response due to network disconnection +- No response due to SW/HW failure of the centralized server + +### 5.6.3 Potential security requirements + +- Load model to be defined to ensure no overloading of the centralized server +- Reliable connectivity between the O-RU and the centralized server +- High availability of the centralized server +- In case the connectivity to the central server is not available, local users to be activated and used until the connectivity is resolved + +## 5.7 Key Issue #7: Categorisation of users that need to centrally and locally managed + +### 5.7.1 Key issue detail + +The purpose of centralized user management is to have effective administration and accountability of O-RU users. It is recommended that the users of the O-RU are being categorized into central and local users to ensure that centrally administered users are kept at a maximum and local users are at a minimum with a well defined need. + +### 5.7.2 Security threats + +- O-RU user information could be mismanaged, classifying users managed centralized as local users, defeating the purpose of central authentication, authorization and administration. + +### 5.7.3 Potential security requirements + +- Categorisation of central and local users for the O-RU +- Minimise the usage of local users and maximise the usage of central users + +When a user connects to a O-RU, first check if the user exists in central server, if no user found then check locally + +## 5.8 Key Issue #8: Fetching initial security configuration data from a Software and Configuration Server + +### 5.8.1 Key issue detail + +The SCS is a server that can provide initial configuration data to an O-RU before first connection to an O-RU Controller similar to what is described in 3GPP TS 28.314 [9] and TS 28.315 [10]. The O-RU can get the address to the SCS from the DHCP server. + +The initial configuration data can be security related data such as the address to a central AA server, trusted certificates etc. + +### 5.8.2 Security threats + +The security threats identified with O-RU fetching initial configuration from SCS: + +- Without a secure connection, the SCS can be fake. +- Without a secure connection, the configuration data can be tampered with in transit. +- Without trust information, e.g. a trusted certificate, the O-RU cannot verify that the SCS is ok. This is however the same risk as the O-RU has with the O-RU Controller in current specification. + +### 5.8.3 Potential security requirements + +The connection to the SCS server that can provide initial configuration data to an O-RU should be authenticated and should be confidentiality and integrity protected. + +## 5.9 Key Issue #9: Secure transport to the centralized authentication server + +### 5.9.1 Key issue detail + +Data in transit can be intercepted between the O-RU and the central server. From this perspective, there should be options of secure transport for the reason that credentials will be shared for authentication and authorization purposes which should not be compromised. There is a possibility to also have a compromised central server. + +### 5.9.2 Security threats + +- Security related credentials required for authentication and authorization purpose between the O-RU and the central server could be compromised. ([i.1] T-O-RAN-08) +- Threats to compromised central server + +### 5.9.3 Potential security requirements + +To protect against malicious activity on the transport between the O-RU and central server, the service interface should provide for + +- Confidentiality: protect the data transferred against eavesdropping +- Integrity: protect the data transferred against malicious change + +- Authenticity: mutually authenticate both endpoints (O-RU and central server) + +As an option, secure and efficient standard protocols could be considered from the below to guard against the above threats + +- LDAPS +- OpenID and OAuth +- RADIUS due to the presence of Netconf/Yang on the O-RUs + +## 5.10 Key Issue #10: Secure storage of O-RU credentials + +### 5.10.1 Key issue detail + +Improper or missing controls for protection of security credentials at rest, generated by O-RAN components, may not allow a correct and rapid audit in case of a security incident occurrence. Security restoration is delayed. Missing availability and integrity of security credentials could lead to delays, wrong results, delays in security restoration and threat persistence ([i.1] §5.4.1.1). A secure mechanism for storing the credentials of the O-RU in the central server should be required. The credentials of the O-RU could be + +- Username and password +- Certificates +- Tokens + +### 5.10.2 Security threats + +- O-RU related credentials could be compromised by an attacker if the storage is not secure. The important aspect is that as all the data is stored centrally and the entire network could be potentially sabotaged if not secured. ([i.1] T-O-RAN-06). + +### 5.10.3 Potential security requirements + +Secure mechanism of storing various types of credentials of the O-RU + +- Management of username and password centrally with salting mechanisms and a one-way hash +- Certificates centrally managed with respect to users encompassing the life cycle management of enrollment, renewal and revocation. +- Tokens created centrally in OAuth server and encrypted during motion and refreshing actions + +# 6 Mitigations and Solutions + +## 6.1 Key Issue Analysis + +The 10 identified Key Issues can be grouped into these groups, Local User Management issues, Initial Provisioning, and Central Server Issues. + +The Local User Management Issues can be mitigated by using a Centralized User Management Service, however that means that the other two groups of issues come into play. + +The Key Issues with Initial Provisioning of data needed to securely connect to the central AA server can be mitigated by the services proposed for distributing Trust Anchors, i.e. Voucher based protocols, BRSKI based or SCS based solutions. It is concluded that DHCP, DNS and RA/CA methods would either not be secure or have the same Initial Provisioning issues. + +The Key Issues related to the Central AA server can be mitigated by placing security requirements on the Central AA server itself. This is however not a component designed by the O-RAN Alliance specifications so only recommendations can be made to the operators. + +## 6.2 Solution #1: Centralized User Management + +To mitigate the listed Key Issues related to Local User Management it is proposed to allow the use of centralized user management services. There are many protocols to choose from and the investigation done on this topic before setting requirements on O1, showed that it was not possible to agree on one single protocol. It is proposed to allow the same protocols on the O-RU as on the O1 entities. + +NOTE: An enquiry to companies participating in WG11 meetings resulted in a change proposal towards the O1 requirement where LDAP with StartTLS was selected as the primary choice of protocol. Proposed requirement: + +REQ-x The O-RU MAY support external user-to-groupmapping with the role based access control concept. + +Proposed security controls: + +CTL-y An O-RU that supports external user to group mapping should support LDAP with StartTLS, and may also support OAuth 2.0, RADIUS with EAP, and TACACS/TACACS+. + +CTL-z The centralized server may be an external 3rd party system or within the ORAN reside within a SMO or O-DU (depending on hierarchical or hybrid mode). + +CTL-zz The centralized server stores the necessary credentials for the O-RU in a secure manner with access control (mapping to KI10) + +CTL-zx An O-RU that supports external user to group mapping may support SAML and OIDC. + +## 6.3 Solution 2#: Initial Provisioning + +To mitigate the listed Key Issues related to Initial Provisioning of data needed to securely connect to the central AA server it is possible to use the already defined security control [i.1]: + +SEC-CTL-TAP-5: An O-RAN PNF may support 3GPP SCS [66], [67], [68] for download of initial security configuration. + +## 6.4 Solution #3 High Availability + +To mitigate the listed Key Issues related to the use of a Centralized Authentication and Authorization Server it is proposed to recommend operators to plan the deployment with high availability. + +Proposed requirement: + +REQ-x A Centralized Authentication and Authorization Server should support high availability + +REQ-y An O-RU supports minimal local users so that they can be activated during possible disconnection due to unavailability of the centralized user management server. + +# 7 Conclusions + +## 7.1 Key Issue Solution Mapping + +This document currently contains 10 key issues and 3 solutions proposals to address or reduce the risk associated with the key issues. A mapping of the solutions to the key issues is shown here. + +**Table 7.1-1 Key Issue Solution mapping for O-RU Centralized User Management** + +| Key issue | Sol # 1 | Soln #2 | Sol #3 | +|------------------|---------|---------|--------| +| KI 1 | X | | | +| KI 2 | X | | | +| KI 3 | X | | | +| KI 4 | | X | | +| KI 5 | X | | | +| KI 6 | | | X | +| KI 7 | | | | +| KI 8 | | X | | +| KI 9 | X | | | +| KI 10 | X | | | + +# Annex: Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------------|----------------------------------------------------------------------------------------------| +| 2022.07.06 | 00.10 | First draft version | +| 2022.09.28 | 01.00 | First approved version. Key issues identified | +| 2022.11.23 | 01.01 | Included Ericsson CR0033 | +| 2023.02.13 | 01.02 | Included Nokia CR0010, CR0014, CR0015 and Ericsson CR0043 | +| 2023.02.14 | 01.03 | Updated table of contents and history | +| 2023.02.22 | 01.04 | Included Nokia CR0040 and CR0041 | +| 2023.03.01 | 01.05 | Minor editorial corrections | +| 2023.03.01 | 01.06 | Corrected clause numbering | +| 2023.03.02 | 02.00.00 | Moved to new template and removed template text | +| 2023.03.09 | 02.01 | Removed O-RAN Release information as agreed in the plenary. Removed the duplicated Key Issue | +| 2023.07.06 | 03.00 | Added approved CRs to v02.01 | +| 2023.10.02 | 03.01 | Included Nokia CR0108, Nokia CR0109 and NEC CR0003 | +| 2023.11.08 | 01.00.00 | First external version. Renamed to follow naming convention for external documents. | +| 2024.03.06 | R003-v01.00 | Included NEC CR0010, NEC CR0014 | +| 2024.06.19 | R004-v00.01 | Preliminary version for R004 release | +| 2024.06.19 | R004-v00.02 | Included Ericsson CR0143 | +| 2024.07.24 | R004-v03.00 | Final version for July release 2024 | +| 2024.11.05 | R005-v04.00.01 | Included NEC CR0028, ERI CR0169 | +| 2024.11.06 | R005-v04.00.02 | Editorial changes | +| 2024.11.27 | R005-v04.00.03 | Editorial changes | +| 2024.12.03 | R004-v04.00 | Final version for November release 2024 | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/05eb3369301d418dcb82876643e3db9f_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/05eb3369301d418dcb82876643e3db9f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7429cee58f6b43bf97b2e7ad3fe464ee11aaefc7 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/05eb3369301d418dcb82876643e3db9f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15547aceb1e524165623668b58b2c28cd3e14dc6c6309b856741316a94e85300 +size 4494 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2fd5eaeff22262dc085e14adfdb0ad2472ac9dc2 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd2727019ae96e80efda4964e1a871737c2c73277a978726969f55d0e5275c2f +size 4536 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/0f7eaaf98898a601b19b7338053ec63f_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/0f7eaaf98898a601b19b7338053ec63f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a1537d28533ab6a26517199fd4d18e246be38e17 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/0f7eaaf98898a601b19b7338053ec63f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:53a2905b64086c950ed910b4cd981a09bcb3d83841e4ac21c63e399d22a8f1ff +size 7479 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/282ffbe52f9212cc1316956ea9eb7292_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/282ffbe52f9212cc1316956ea9eb7292_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c03f79de487fe0a198157506e4a6ab837c3465ad --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/282ffbe52f9212cc1316956ea9eb7292_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8eccaffe412356ca954e82d9e34f7c6fb19347a49406c0ffc64bae1a3fc5cdda +size 38266 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/359171a069930c765ab1263b2a654639_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/359171a069930c765ab1263b2a654639_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a1d08acd6a846f47410568f3146fd4d9d4fdec18 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/359171a069930c765ab1263b2a654639_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09a8a45c878fe8b591876f0a13bdd7d98ebfb3d937823c68b1155fb786eea93a +size 24362 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3a71b98fcfc274b0603208cc5e23601d7fc924a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84a0e505aa8e8fcec39c03736b466858a7c1ef91abe309cdd2974ee18257e23b +size 4531 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/5f19af628e407fc47cc229cb28b0c74d_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/5f19af628e407fc47cc229cb28b0c74d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..02bf807299fa387926f2c807e775f196b92399c4 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/5f19af628e407fc47cc229cb28b0c74d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9f5b7c33fe2aa4e622fe57045b9618ab51006535fd4cd9de7179b4047f2e4df8 +size 18381 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/65df3d7fd8c004a98402abbd4553913a_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/65df3d7fd8c004a98402abbd4553913a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..10be5e11d4c58c5be943cda35ba248ee5799c042 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/65df3d7fd8c004a98402abbd4553913a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9057d9adaf27df12c40486b4cecffba243e6a0fceec6758370e13f7fcd339ed +size 4526 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/721fd8bad03ea911b51744d701b1a4aa_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/721fd8bad03ea911b51744d701b1a4aa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..444d34b4b2ec6443e539b76b0c8d120f857863be --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/721fd8bad03ea911b51744d701b1a4aa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:22fe24dd5c7f6042a8766011ce1c175eaef6fdc9919f8311e798b8a682fe0017 +size 22345 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/869c5b22b3730d8e406a3238074edd3f_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/869c5b22b3730d8e406a3238074edd3f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4cdc2f079fc13603846752b9ffdabd30c645b67a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/869c5b22b3730d8e406a3238074edd3f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7fd443d28a02d2850aa4cca56bc83291be71fc47d3b7f27cf4c1b6023ae417a7 +size 63846 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/94220bb4f68889783b714d2c1e688efd_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/94220bb4f68889783b714d2c1e688efd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..110be89972bc173151ea7a56918ca43186d502a3 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/94220bb4f68889783b714d2c1e688efd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:68568c6504db3427d1dd24600fca731b9a302ea86600470cf1e58d2d0019caf8 +size 19121 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/a5ed9f7893313da659648a481972e515_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/a5ed9f7893313da659648a481972e515_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..612ac94c797dbb76e6631d341dda9aa8e4c7b872 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/a5ed9f7893313da659648a481972e515_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4b6787f83d874ee0d1d3ef1dc65b886904b7fcad0243c192fafcf3eb1252e806 +size 69564 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/a9f92f13a8587924d496f455cadf59d9_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/a9f92f13a8587924d496f455cadf59d9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eff59e53c4bd864d2c73cb3c2f6c596e545abd68 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/a9f92f13a8587924d496f455cadf59d9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f97acbc182e050f299d6b64a46eae2cf50c53f80a4aa16694172fbc8cb0021b0 +size 26142 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/ab94b23269a03a4310fc4b669f8679cd_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/ab94b23269a03a4310fc4b669f8679cd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a03139e5731cff8460dcb3e4094862abc5214402 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/ab94b23269a03a4310fc4b669f8679cd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:24f16a2d88e94987402589fb05342140c3374951daec9f2f814f457fc1b042a0 +size 68703 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/ac37184bafed7ae560e488fe0b61aa9a_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/ac37184bafed7ae560e488fe0b61aa9a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4e2a90102be22ee6fd5d11548a788da001fa00f7 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/ac37184bafed7ae560e488fe0b61aa9a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9acd817a4a8fab6d371ddd49fc2e6cf1fa2ecb55ad0435d3a743ee832b8e5188 +size 111144 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/b5cde1e675c6bae94be8ef7f70a7a15c_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/b5cde1e675c6bae94be8ef7f70a7a15c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b3532a6834ee3d5bfa795a1aa9ae96733f40306b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/b5cde1e675c6bae94be8ef7f70a7a15c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fcc9fd19d3b5439c5daec8ffc59928699441384a8e7529f5f24a74809f54e0b9 +size 58752 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/c2e33ca2a94cbb0b755f26440be1c0ca_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/c2e33ca2a94cbb0b755f26440be1c0ca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9853a9d0d79260a39adcc012f1c7878d672366db --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/c2e33ca2a94cbb0b755f26440be1c0ca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:adfd8e419d1aedfc9dc5de21bd3c2c0fe5f723e1319bf25221be84e9c18d30f7 +size 16086 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/e624c48fdf2ecdb2564d6d46a233e72b_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/e624c48fdf2ecdb2564d6d46a233e72b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1fb34980426e9d1d301da2dce43953db5a9fc69a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/e624c48fdf2ecdb2564d6d46a233e72b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8bf1aba2b23547743cfdefb052febb062d0dd9787811e40918c7c6efd25708e2 +size 18054 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/e6b8f4a7741fa070925f6166666c1f20_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/e6b8f4a7741fa070925f6166666c1f20_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..914e0459bb9a535fd14099b3aa511bbdfce38932 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/e6b8f4a7741fa070925f6166666c1f20_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b526661f3429e81db62968f08d44fca991d17c1253ec9e73a564fbc693bd803b +size 7902 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7423b16589e846f2b16ec9a44a377d2efd9a9090 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b000e2a5c716ba0590040bc3dc3321438d999e8b057249129751dff05131f8c +size 4564 diff --git a/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/raw.md b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..700a60f7c263f1db8ce505de4f92c6fb61b32608 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00/raw.md @@ -0,0 +1,1882 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****OAuth 2.0 Security** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------| +| List of figures ..... | 3 | +| List of tables ..... | 4 | +| Foreword..... | 5 | +| Modal verbs terminology ..... | 5 | +| 1 Scope ..... | 6 | +| 1.1 Consideration ..... | 6 | +| 2 References ..... | 6 | +| 2.1 Informative references ..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 7 | +| 3.1 Terms ..... | 7 | +| 3.2 Symbols..... | 9 | +| 3.3 Abbreviations ..... | 9 | +| 4 Study and recommendation from IETF, 3GPP and ETSI on OAuth 2.0 ..... | 9 | +| 4.1 General..... | 9 | +| 4.2 IETF 6749 ..... | 9 | +| 4.3 IETF 8705 ..... | 9 | +| 4.4 3GPP TS 33.122..... | 9 | +| 4.5 ETSI NFV SEC022..... | 9 | +| 5 Threats..... | 9 | +| 5.1 Assets ..... | 9 | +| 5.1.1 O-RAN Architecture Elements ..... | 9 | +| 5.1.2 O-RAN interfaces ..... | 10 | +| 5.2 Threats Template ..... | 10 | +| 5.3 Potential Threat and Exploits..... | 11 | +| 5.4 OAuth 2.0 Threats..... | 11 | +| 6 Threat Analysis ..... | 12 | +| 6.1 General OAuth 2.0 Threats ..... | 12 | +| 6.2 Authorization Server related Threats ..... | 19 | +| 7 Risk Assessment..... | 22 | +| 8 Security Controls..... | 22 | +| 9 OAuth 2.0 Authorization framework ..... | 22 | +| 9.1 Overview..... | 22 | +| 9.2 Key Issues ..... | 23 | +| 9.3 Solutions ..... | 27 | +| 9.3.1 Solution #1: Registration of rApp..... | 27 | +| 9.3.2 Solution #2: Request access token for R1 services..... | 29 | +| 9.3.3 Solution #3: R1 services request with access token..... | 32 | +| 9.3.4 Solution #4: Secure transmission of request and response between client to authorization server, between client and resource server for R1, A1 and O2..... | 34 | +| 9.3.5 Solution #5: Support for RBAC..... | 40 | +| 9.3.6 Solution #6: Profile for client credentials grant type clients..... | 43 | +| 10 Study and recommendation an O-RAN Authorization Server architecture..... | 46 | +| 11 Conclusion..... | 46 | +| Annex:Change history/Change request (history) ..... | 47 | + +# --- List of figures + +| | | +|----------------------------------------------------------------------------------------|----| +| Figure 9.1-1 OAuth 2.0 framework for O-RAN Architecture elements and applications..... | 22 | +| Figure 9.3.1-1 rApp Registration use case sequence diagram ..... | 28 | +| Figure 9.3.2-1 Request access token for R1 services use case sequence diagram ..... | 31 | +| Figure 9.3.3-1 R1 Service request using access token use case sequence diagram..... | 33 | +| Figure 9.3.4-1 Transmission between client and authorization server..... | 36 | +| Figure 9.3.4-2 Transmission between client and resource server..... | 36 | +| Figure 9.3.4-3 Tls_client_OAuth method..... | 38 | +| Figure 9.3.4-4 Private_key_JWT with JWE method..... | 38 | +| Figure 9.3.4-5 Private_key_JWT method..... | 38 | +| Figure 9.3.4-6 Client_secret_JWT method..... | 39 | +| Figure 9.3.4-7 Client_secret_basic method..... | 39 | +| Figure 9.3.4-8 Client_secret_post method..... | 39 | +| Figure 9.3.4-9 Self_signed_tls_client_auth method..... | 40 | +| Figure 9.3.5-1 RBAC for client credentials..... | 42 | +| Figure 9.3.6-1 Profile for confidential client..... | 45 | + +# --- List of tables + +| | | +|-------------------------------------------------------------------------------------------------|----| +| Table 5.4-1 OAuth 2.0 Threats ..... | 11 | +| Table 9.3.1-1 rApp Registration use case ..... | 27 | +| Table 9.3.2-1 Request access token for R1 services use case..... | 30 | +| Table 9.3.3-1 R1 Service request using access token use case ..... | 32 | +| Table 9.3.4-1 Use case of secure data transmission between client and authorization server..... | 35 | +| Table 9.3.4-2 Authentication methods..... | 37 | +| Table 9.3.5-1 Use case of RBAC..... | 41 | +| Table 9.3.6-1 Client credentials grant type client profile..... | 44 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The technical report defines the authorization framework for O-RAN elements using OAuth 2.0 and applies to the HTTP and Kafka based APIs [i.13] [i.18] used in the R1, O1, O2, A1, FH m-plane [i.17] and Y1 interfaces. + +For this objective, the present document + +- Defines the procedure flow for token registration process, token request process, token verification process and token authorization process. It will specify the token scope metadata for O-RAN. +- Analyses the existing specifications related to OAuth 2.0 such as O-RAN Security protocol specification, IETF RFC 8705 [i.6], IETF RFC 6749 [i.5], 3GPP TS29.501 [i.3], 3GPP TS 33.122 [i.4], 3GPP TS 28.319 [i.19] and ETSI NFV SEC-022 [i.7]. This is used as input to the present document. +- Analyses the security threat arising from the misuse of the access token and defines the security requirements associated to access token. +- Provides the study and recommendation of an authorization server architecture to overlay on the O-RAN architecture. + +## 1.1 Consideration + +This Technical Report makes the following considerations: + +- O-RAN Alliance WG1 has identified the key functions and interfaces [i.9] adopted in O-RAN and this will influence the set of assets to be protected for OAuth 2.0 framework. +- This TR will perform a detailed study of the OAuth 2.0 authorization server for O-RAN Architecture Elements and interface. +- Clause 4.7 in O-RAN Security Protocol Security specification [i.1] will be considered as the baseline text for the OAuth 2.0 framework. +- The recommended security requirements and controls provided in this report will be shared with the impacted O-RAN Alliance working group, such as WG1, WG2, WG3, WG6 and WG10 prior publishing them as normative. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +[i.1] O-RAN ALLIANCE TS: "O-RAN Security Protocols Specification" + +[i.2] O-RAN ALLIANCE TS: "O-RAN Security Requirements and Controls Specification" + +[i.3] 3GPP TS 29.501:"5G System; Network Function Repository Services" + +[i.4] 3GPP TS 33.122:"Security aspects of Common API Framework (CAPIF) for 3GPP northbound APIs" + +[i.5] IETF RFC 6749: "The OAuth 2.0 Authorization Framework" + +[i.6] IETF RFC 8705: "OAuth 2.0 Mutual-TLS Client Authentication and Certificate-Bound Access Tokens" + +[i.7] ETSI GS NFV-SEC 022: "Network Functions Virtualisation (NFV) Release 2; Security; Access Token" + +Specification for API Access" + +- [i.8] IETF RFC 6819: "OAuth 2.0 Threat Model and Security Considerations" +- [i.9] O-RAN ALLIANCE TS: "O-RAN Architecture Description" +- [i.10] 3GPP TS 23.222: "Common API Framework for 3GPP Northbound APIs" +- [i.11] 3GPP TS 29.222: "Common API Framework for 3GPP Northbound APIs" +- [i.12] IETF RFC 2616: "Hypertext Transfer Protocol -- HTTP/1.1" +- [i.13] O-RAN TS: "R1 interface: General Aspects and Principles" ("R1GAP") +- [i.14] O-RAN TS: "Non-RT RIC & A1/R1 Interface: Use Cases and Requirements" ("UCR") +- [i.15] O-RAN TR: "Decoupled SMO" +- [i.16] O-RAN TR: "SMO Security" +- [i.17] O-RAN TS: "Management Plane Specification" +- [i.18] Kafka Documentation +- [i.19] 3GPP TS 29.319: "Management and orchestration; Access control for management services" +- [i.20] O-RAN ALLIANCE TR: "O-RAN Threat Modelling and Risk Assessment" +- [i.21] Final: OpenID Connect Core 1.0 incorporating errata set 2 +- [i.22] IETF RFC 7591: OAuth 2.0 Dynamic Client Registration Protocol +- [i.23] IETF RFC 8414: OAuth 2.0 Authorization Server Metadata + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +**A1:** Interface between non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**Access Token:** credentials used to obtain access. It is a string, usually opaque to the client, representing an authorization issued to the client. Tokens represent specific scopes and durations of access, granted by the resource owner, and enforced by the resource server and authorization server (see [i.5], clause 1.4). + +**Authorization code:** The authorization code is obtained by using an authorization server as an intermediary between the client and resource owner. Instead of requesting authorization directly from the resource owner, the client directs the resource owner to an authorization server (via its user-agent as defined in [IETF RFC 2616]), which in turn directs the resource owner back to the client with the authorization code. ([i.5], clause 1.3.1) + +**Authorization Server:** The server issuing access tokens to the client after successfully authenticating the resource owner and obtaining authorization. ([i.5], clause 1.1) + +**Client:** An application making protected resource requests on behalf of the resource owner and with its authorization. The term "client" does not imply any particular implementation characteristics (e.g., whether the application executes on a server, a desktop, or other devices). ([i.5], clause 1.1) + +**Client Credentials:** The client credentials (or other forms of client authentication) can be used as an authorization grant when the authorization scope is limited to the protected resources under the control of the client, or to protected resources previously arranged with the authorization server. Client credentials are used as an authorization grant typically when the client is acting on its own behalf (the client is also the resource owner) or is requesting access to protected resources based on an authorization previously arranged with the authorization server. ([i.5], clause 1.3.4) + +**Confidential client:** A client capable of maintaining the confidentiality of their credentials (e.g., client implemented on a secure server with restricted access to the client credentials), or capable of secure client authentication using other means as in clause 2.1 of [i.5]. + +**CSRF:** Cross-site request forgery (CSRF) is a web-based attack whereby HTTP requests are transmitted from a user that the web site trusts or has authenticated (e.g., via HTTP redirects or HTML forms). ([i.8], clause 4.4.1.8) + +**Near-Real-Time RAN Intelligent Controller:** An O-RAN Network Function (NF) that enables near-real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. It may include AI/ML (Artificial Intelligence / Machine Learning) workflow including model training, inference and updates. + +**Non-Real-Time RAN Intelligent Controller:** A functionality within SMO that drives the content carried across the A1 interface. It is comprised of the Non-RT RIC Framework and the Non-RT RIC Applications (rApps) whose services are defined below. + +**Non-RT RIC Applications (rApps):** Modular applications that leverage the functionality exposed via the Non-RT RIC Framework's R1 interface to provide added value services relative to RAN operation, such as driving the A1 interface, recommending values and actions that may be subsequently applied over the O1/O2 interface and generating "enrichment information" for the use of other rApps. The rApp functionality within the Non-RT RIC enables non-real-time control and optimization of RAN elements and resources and policy-based guidance to the applications/features in Near-RT RIC. + +**O2:** Interface between SMO framework as specified in clause 5.3.1 and the O-Cloud for supporting O-RAN virtual network functions. Please refer to [i.9] for more information. + +**Open Redirector:** An open redirector is an endpoint using a parameter to automatically redirect a user-agent to the location specified by the parameter value without any validation. ([i.5], clause 10.15) + +**R1 Interface:** Interface between rApps and Non-RT RIC Framework via which R1 Services can be produced and consumed. + +**Refresh token:** Refresh tokens are credentials used to obtain access tokens. Refresh tokens are issued to the client by the authorization server and are used to obtain a new access token when the current access token becomes invalid or expires, or to obtain additional access tokens with identical or narrower scope (access tokens may have a shorter lifetime and fewer permissions than authorized by the resource owner). ([i.5], clause 1.5) + +**Resource Owner:** An entity capable of granting access to a protected resource. When the resource owner is a person, it is referred to as an end-user. ([i.5], clause 1.1) + +**Resource Server:** The server hosting the protected resources, capable of accepting and responding to protected resource requests using access tokens. ([i.5], clause 1.1) + +**SMO:** A Service Management and Orchestration framework. + +**User-Agent:** The User-Agent request-header field contains information about the user agent originating the request. This is for statistical purposes, the tracing of protocol violations, and automated recognition of user agents for the sake of tailoring responses to avoid particular user agent limitations. ([i.12], clause 14.43) + +**xApp:** An application designed to run on the Near-RT RIC. Such an application is likely to consist of one or more microservices and at the point of on-boarding will identify which data it consumes and which data it provides. The application is independent of the Near-RT RIC and may be provided by any third party. The E2 enables a direct association between the xApp and the RAN functionality. + +**Y1:** An interface over which RAN analytics services are exposed by the Near-RT RIC to be consumed by Y1 consumers. + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +None + +## 3.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply: + +| | | +|-------------|-------------------------------------------| +| 3GPP | 3rd Generation Partnership Project | +| Near-RT RIC | Near-Real-Time RAN Intelligent Controller | +| rApp | Non-RT RIC Application | +| SMO | Service Management and Orchestration | +| xApp | Near-RT RIC Application | + +# --- 4 Study and recommendation from IETF, 3GPP and ETSI on OAuth 2.0 + +## 4.1 General + +## 4.2 IETF 6749 + +Editor's note: This clause will do the study related to OAuth 2.0 framework from IETF RFC 6749 + +## 4.3 IETF 8705 + +Editor's note: This clause will do the study related to OAuth 2.0 Mutual-TLS Client Authentication and Certificate-Bound Access Tokens from IETF RFC 8705 + +## 4.4 3GPP TS 33.122 + +Editor's note: This clause will do the study related to OAuth 2.0 recommended from 3GPP specification (23.222, 29.222, 33.122, TS29.501) + +## 4.5 ETSI NFV SEC022 + +Editor's note: This clause will do the study related to OAuth 2.0 mechanism and definition from ETSI NFV SEC022 + +# --- 5 Threats + +## 5.1 Assets + +The following O-RAN elements and interfaces should be considered for the security threat analysis: + +### 5.1.1 O-RAN Architecture Elements + +- Service Management and Orchestration (SMO) + +- Non-RT RIC +- Near-RT RIC +- O-Cloud +- O-CU-CP +- O-CU-UP +- O-DU +- O-RU +- O-eNB +- rApps +- xApps + +### 5.1.2 O-RAN interfaces + +- R1 interface +- O2 interface +- A1 interface +- Y1 interface +- Near RT RIC API's + +## 5.2 Threats Template + +Template to present the threat characteristics: + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------| +| Threat ID | O-RAN threat ID | +| Threat title | [Threat Title will include suitable reference of 3GPP/IETF/ETSI] | +| Threat description | Introduction about the threat | +| Threat type | Spoofing
    Tampering
    Repudiation
    Information disclosure
    Denial of Service
    Elevation of Privilege | +| Vulnerability | | +| Impact type | Authenticity
    Integrity
    Non-repudiation
    Confidentiality
    Availability
    Authorization | +| Affected Assets | Asset identification | + +## 5.3 Potential Threat and Exploits + +## 5.4 OAuth 2.0 Threats + +The following threats to OAuth 2.0 have been identified and are analyzed in clause 6 Threat Analysis. + +Table 5.4-1 – OAuth 2.0 Threats + +| Threat-Id | Threat Description (Brief) | +|---------------------------------------------|-------------------------------------------------------------------------------------| +| General OAuth 2.0 Threats | | +| T-OAuth-G-01 | Obtaining client secrets | +| T-OAuth-G-02 | Obtaining refresh tokens | +| T-OAuth-G-03 | Obtaining access tokens | +| T-OAuth-G-04 | Eavesdropping access tokens | +| T-OAuth-G-05 | Disclosure of client credentials during transmission | +| T-OAuth-G-06 | Open redirectors on client | +| T-OAuth-G-07 | Obtain a deployment specific secret | +| T-OAuth-G-08 | Obtaining authorization by code substitution (OAuth Login) | +| T-OAuth-G-09 | Access token leak in transport/endpoints | +| T-OAuth-G-10 | Malicious client obtains existing authorization by fraud | +| T-OAuth-G-11 | Malicious client obtains authorization | +| T-OAuth-G-12 | Accidental exposure of passwords at client site | +| T-OAuth-G-13 | Client obtains scopes without end-user authorization and possible misconfigurations | +| T-OAuth-G-14 | Client obtains refresh token through automatic authorization | +| T-OAuth-G-15 | Eavesdropping refresh tokens from authorization server | +| T-OAuth-G-16 | Obtaining refresh token by online guessing | +| T-OAuth-G-17 | Refresh token phishing by counterfeit authorization server | +| T-OAuth-G-18 | Guessing access tokens | +| T-OAuth-G-19 | Access token phishing by counterfeit resource server | +| T-OAuth-G-20 | Abuse of token by legitimate resource server or client | +| T-OAuth-G-21 | Token leakage via log files and http referrers | +| T-OAuth-G-22 | User unintentionally grants too much access scope | +| T-OAuth-G-23 | Leak of confidential data in HTTP proxies | +| T-OAuth-G-24 | Replay of authorized resource server requests | +| Authorization Server related threats | | +| T-OAuth-AS-01 | Password phishing by counterfeit authorization server | +| T-OAuth-AS-02 | Obtaining access tokens from authorization server database | +| T-OAuth-AS-03 | Obtaining client secret from authorization server database | +| T-OAuth-AS-04 | Online guessing of authorization codes | +| T-OAuth-AS-05 | DoS attacks that exhaust resources | +| T-OAuth-AS-06 | CSRF attack against redirect-uri | +| T-OAuth-AS-07 | Resource owner impersonation | +| T-OAuth-AS-08 | DoS using manufactured authorization "codes" | +| T-OAuth-AS-09 | Obtaining user passwords from authorization server database | + +| | | +|---------------------------------------|---------------------------------------------------------------------------------------------------------------------------| +| T-OAuth-AS-10 | Obtaining the resource owner password credentials by online guessing | +| T-OAuth-AS-11 | Obtaining refresh token from authorization server database | +| Access Control related Threats | | +| T-O-RAN-03 | Attacks from the internet exploit weak authentication and access control to penetrate O-RAN network boundary | +| T-O-RAN-06 | An attacker exploits insufficient/improper mechanisms for authentication and authorization to compromise O-RAN components | +| T-R1-01 | An attacker gains unauthorized access to R1 services | +| T-R1-05 | An attacker gains unauthorized access to data | +| T-AppLCM-04 | Attacker exploits missing or improperly defined elements of application's SecurityDescriptor | +| T-GEN-02 | Malicious access to exposed services using valid accounts | +| T-SMO-10 | Sensitive data at rest is exposed to an internal attacker | + +NOTE: In above table 5.4-1, access control related threats are defined in [i.20] + +# 6 Threat Analysis + +## 6.1 General OAuth 2.0 Threats + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-01 | +| Threat title | Obtaining client secrets, IETF RFC 6819 [i.8], clause 4.1.1 | +| Threat description | A malicious actor may be able to get access to the secrets of O-RAN elements and obtain the tokens in order to replay its refresh tokens and authorization codes. | +| Threat type | Information disclosure
    Elevation of Privilege | +| Impact type | Confidentiality
    Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-02 | +| Threat title | Obtaining refresh tokens, IETF RFC 6819 [i.8], clause 4.1.2 | +| Threat description | A malicious actor may try to get the file system access of the local storage of O-RAN elements and read the refresh tokens. A malicious actor may use the compromised refresh token for a malicious application. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | O-RAN Architecture Elements that obtain an access token from an OAuth authorization server (e.g., rApp, xApp) | + +| | | +|-----------|---------------------| +| Threat ID | T-OAuth-G-03 | +|-----------|---------------------| + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Obtaining access tokens, IETF RFC 6819 [i.8], clause 4.1.3 | +| Threat description | Access tokens may be stolen by a malicious actor from the local storage if the O-RAN elements stores them in a local storage that is accessible to other O-RAN elements or applications without restriction. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | O-RAN Architecture Elements and Applications acting as an OAuth client (e.g., rApp, xApp) | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-04 | +| Threat title | Eavesdropping access tokens, IETF RFC 6819 [i.8], clause 4.3.1 | +| Threat description | A malicious actor may attempt to eavesdrop access tokens in transit from the authorization server to the O-RAN elements and applications | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | O-RAN Architecture Elements and Applications acting as an OAuth client (e.g., rApp, xApp) | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-05 | +| Threat title | Disclosure of client credentials during transmission, IETF RFC 6819 [i.8], clause 4.3.3 | +| Threat description | A malicious actor may attempt to eavesdrop the transmission of O-RAN elements credentials between the application and authorization server during the O-RAN elements authentication process or during OAuth token requests. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | O-RAN Architecture Elements and Applications acting as OAuth clients (e.g., rApp, xApp) | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-06 | +| Threat title | Open redirectors on client, IETF RFC 6819 [i.8], clause 4.1.5 | +| Threat description | A malicious actor may use an open redirector operated by the O-RAN Applications to construct a redirect URI that will pass the authorization server validation but will send authorization code to an endpoint under the control of a malicious actor. | +| Threat type | Information disclosure | +| Impact type | Authenticity | +| Affected Asset | O-RAN Elements and Applications acting as an OAuth client (e.g., rApp, xApp) | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-07 | +| Threat title | Obtain a deployment-specific secret, IETF RFC 6819 [i.8], clause 4.1.1 | +| Threat description | An attacker may try to gain the secret from a O-RAN client installation, either from a resource server or O-RAN Applications. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-08 | +| Threat title | Obtaining authorization by code substitution (OAuth Login), IETF RFC 6819 [i.8], clause 4.4.1.13 | +| Threat description | An attacker could attempt to log into an application using a victim's identity. Applications relying on identity data provided by an OAuth protected service API to login users are vulnerable to this threat. | +| Threat type | Information Disclosure | +| Impact type | Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-09 | +| Threat title | Access token leak in transport/endpoints, IETF RFC 6819 [i.8], clause 4.4.2.1 | +| Threat description | A token may be eavesdropped by an attacker. The token is sent from the server to the client via a URI fragment of the redirect URI. If the communication is not secured or the endpoint is not secured, the token could be leaked by parsing the returned URI. | +| Threat type | Information Disclosure | +| Impact type | Authorization | +| Affected Asset | OAuth authorization server, O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-10 | +| Threat title | Malicious client obtains existing authorization by fraud, IETF RFC 6819 [i.8], clause 4.2.3 | +| Threat description |

    Authorization servers may wish to automatically process authorization requests from client that have been previously authorized by the user. When the user is redirected to the authorization server's end-user authorization endpoint to grant access, the authorization server detects that the user has already granted access to that particular client. Instead of prompting the user for approval, the authorization server automatically redirects the user back to the client.

    A malicious client may exploit that feature and try to obtain such an authorization "code" instead of the legitimate client.

    | + +| | | +|----------------|-------------------------------------------------| +| Threat type | Spoofing
    Repudiation | +| Impact type | Authorization
    Non repudiation | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|-----------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-11 | +| Threat title | Malicious client obtains authorization, IETF RFC 6819 [i.8], clause 4.4.2.3 | +| Threat description | A malicious client may attempt to obtain a token by fraud. | +| Threat type | Spoofing
    Repudiation | +| Impact type | Authorization
    Non repudiation | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-12 | +| Threat title | Accidental exposure of passwords at client site, IETF RFC 6819 [i.8], clause 4.4.3.1 | +| Threat description | If the client does not provide enough protection, an attacker could retrieve the passwords for a user. | +| Threat type | Information Disclosure | +| Impact type | Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-13 | +| Threat title | Client obtains scopes without end-user authorization and possible misconfigurations, IETF RFC 6819 [i.8], clause 4.4.3.2 | +| Threat description | An O-RAN Application like an rApp or xApp intentionally or unintentionally obtains a token with scope unknown for, or unintended by, the resource owner. | +| Threat type | Tampering
    Elevation of privilege | +| Impact type | Confidentiality
    Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|-----------|---------------------| +| Threat ID | T-OAuth-G-14 | +|-----------|---------------------| + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Client obtains refresh token through automatic authorization, IETF RFC 6819 4.4.3.3 [i.8], clause 4.4.3.3 | +| Threat description | An O-RAN application like an rApp or xApp obtains intentionally or unintentionally a long-term authorization represented by a refresh token even if the resource owner did not intend so | +| Threat type | Tampering
    Elevation of privilege | +| Impact type | Confidentiality
    Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-15 | +| Threat title | Eavesdropping refresh tokens from authorization server, IETF RFC 6819 [i.8], clause 4.5.1 | +| Threat description | An O-RAN Application like an rApp or xApp may eavesdrop refresh tokens when they are transmitted from the authorization server to the client. | +| Threat type | Tampering
    Elevation of privilege | +| Impact type | Confidentiality
    Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-16 | +| Threat title | Obtaining refresh token by online guessing, IETF RFC 6819 [i.8], clause 4.5.3 | +| Threat description | An O-RAN Application like an rApp or xApp may try to guess valid refresh token values and send it using the grant type "refresh_token" in order to obtain a valid access token. | +| Threat type | Tampering
    Elevation of privilege | +| Impact type | Confidentiality
    Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-17 | +| Threat title | Refresh token phishing by counterfeit authorization server, IETF RFC 6819 [i.8], clause 4.5.4 | +| Threat description | An O-RAN Application like an rApp or xApp could obtain valid refresh tokens by proxying requests to the authorization server, given the assumption that the authorization server URL is well-known at development time or can at least be obtained from a well-known resource server | +| Threat type | Tampering
    Spoofing
    Elevation of privilege | +| Impact type | Confidentiality | + +| | | +|----------------|-------------------------------------------------| +| Affected Asset | Authorization | +| | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-18 | +| Threat title | Guessing access tokens, IETF RFC 6819 [i.8], clause 4.6.3 | +| Threat description | Access to a single user's data is possible where an attacker may place a malicious rApp or xApp and attempt to guess the access token values based on knowledge from other access tokens. | +| Threat type | Tampering
    Elevation of privilege | +| Impact type | Confidentiality
    Authorization | +| Affected Asset | O-RAN Architecture Elements like the SMO, Near-RT RIC | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-19 | +| Threat title | Access token phishing by counterfeit resource server, IETF RFC 6819 [i.8], clause 4.6.4 | +| Threat description | An O-RAN Application like an rApp or xApp may send a valid access token to a counterfeit resource server where the server in turn uses that token to access other services on behalf of the resource owner. | +| Threat type | Tampering
    Spoofing
    Elevation of privilege | +| Impact type | Confidentiality
    Authorization | +| Affected Asset | O-RAN Architecture Elements like the SMO, Near-RT RIC | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-20 | +| Threat title | Abuse of token by legitimate resource server or client, IETF RFC 6819 [i.8], clause 4.6.5 | +| Threat description | An O-RAN legitimate resource server which is protecting the resources could possibly use an access token to access another resource server. In a similar manner an O-RAN Application like an rApp or xApp could try to use a token obtained for one server on another resource server | +| Threat type | Tampering
    Elevation of privilege | +| Impact type | Confidentiality
    Authorization | +| Affected Asset | O-RAN Architecture Elements like the SMO, Near-RT RIC | + +| | | +|--------------|-----------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-21 | +| Threat title | Token leakage via log files and HTTP referrers, IETF RFC 6819 [i.8], clause 4.6.7 | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | An O-RAN Application like an rApp or xApp could be implemented wrongly with respect to sending the access tokens URI query parameters and subsequently leak the access tokens to the log files and the HTTP "referer" | +| Threat type | Tampering
    Elevation of privilege | +| Impact type | Confidentiality
    Authorization | +| Affected Asset | O-RAN Architecture Elements like the SMO, Near-RT RIC | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-22 | +| Threat title | User unintentionally grants too much access scope, IETF RFC 6819 [i.8], clause 4.2.2 | +| Threat description | An O-RAN Application like an rApp or xApp while obtaining end-user authorization, it may not understand the scope of the access being granted and to whom, or it may end up providing an access to resources that should not be permitted. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-23 | +| Threat title | Leak of confidential data in HTTP proxies, IETF RFC 6819 [i.8], clause 4.6.6 | +| Threat description | As specified in SPS clause 4.7, OAuth HTTP authentication scheme is optional. However, as per [IETF RFC 2616] it relies on the Authorization and WWW-Authenticate headers to distinguish authenticated content so that it can be protected. Proxies and caches, in particular, may fail to adequately protect requests not using these headers. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | O-RAN Architecture Elements like the rApp, xApp | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-G-24 | +| Threat title | Replay of authorized resource server requests, IETF RFC 6819 [i.8], clause 4.6.2 | +| Threat description | An attacker may attempt to replay valid requests to obtain or modify/delete the O-RAN application data. | +| Threat type | Tampering | +| Impact type | Integrity | + +| | | +|-----------------------|-----------------------------------------------------------------------------| +| Affected Asset | OAuth authorization server, O-RAN Architecture Elements like the rApp, xApp | +|-----------------------|-----------------------------------------------------------------------------| + +## 6.2 Authorization Server related Threats + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-AS-01 | +| Threat title | Password phishing by counterfeit authorization server, IETF RFC 6819 [i.8], clause 4.2.1 | +| Threat description | A malicious actor may steal confidential data (e.g., Password) by intercepting the O-RAN Application's request and exploit the URL endpoints managed by authorization server. | +| Threat type | Information disclosure | +| Impact type | Authenticity | +| Affected Asset | OAuth authorization server | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-AS-02 | +| Threat title | Obtaining access tokens from authorization server database, IETF RFC 6819 [i.8], clause 4.3.2 | +| Threat description | A malicious actor may obtain access tokens from the authorization server's database by gaining access to the database or launching a SQL injection attack. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | OAuth authorization server | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-AS-03 | +| Threat title | Obtaining client secret from authorization server database, IETF RFC 6819 [i.8], clause 4.3.4 | +| Threat description | A malicious actor may obtain valid client_id/secrets combinations from the authorization server's database by gaining access to the database or launching a SQL injection attack. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | OAuth authorization server | + +| | | +|---------------------|-----------------------------------------------------------------------------| +| Threat ID | T-OAuth-AS-04 | +| Threat title | Online guessing of authorization codes, IETF RFC 6819 [i.8], clause 4.4.1.3 | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | A malicious actor may try to guess valid authorization code values and send the guessed code value using the grant type code in order to obtain a valid access token. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | OAuth authorization server | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-AS-05 | +| Threat title | DoS attacks that exhaust resources, IETF RFC 6819 [i.8], clause 4.4.1.11 | +| Threat description | A malicious actor may exhaust the pool of authorization codes of the authorization server by repeatedly directing the O-RAN Application to request the access tokens. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | OAuth authorization server | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-AS-06 | +| Threat title | CSRF attack against redirect-uri, IETF RFC 6819 [i.8], clause 4.4.1.8 | +| Threat description | CSRF attacks on OAuth approvals may allow a malicious actor to obtain authorization to OAuth protected resources without the consent of the O-RAN Applications. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | OAuth authorization server | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-AS-07 | +| Threat title | Resource owner impersonation, IETF RFC 6819 [i.8], clause 4.4.1.10 | +| Threat description | A malicious actor may exploit an OAuth authorization server's ability to gain authorization without the OAuth 2.0 resource owner's consent by automatically approving the request using existing authenticated session. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | OAuth authorization server | + +| | | +|--------------|------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-08 | +| Threat title | DoS using manufactured authorization "codes", IETF RFC 6819 [i.8], clause 4.4.1.12 | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | An attacker who owns a botnet may locate the redirect URIs of client that listen on HTTP, access them with random authorization "codes", and cause a large number of HTTPS connections to be concentrated onto the authorization server. This can result in a denial-of-service (DoS) attack on the authorization server. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | OAuth authorization server | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-09 | +| Threat title | Obtaining user passwords from authorization server database, IETF RFC 6819 [i.8], clause 4.4.3.5 | +| Threat description | An attacker may obtain valid username/password combinations from the authorization server's database by gaining access to the database or launching a SQL injection attack. | +| Threat type | Information Disclosure | +| Impact type | Authorization
    Information Disclosure | +| Affected Asset | OAuth authorization server | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-10 | +| Threat title | Obtaining the resource owner password credentials by online guessing, IETF RFC 6819 [i.8], clause 4.4.3.6 | +| Threat description | An attacker may try to guess valid username/password combinations using the grant type "password". | +| Threat type | Information Disclosure | +| Impact type | Authorization | +| Affected Asset | OAuth authorization server | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OAuth-11 | +| Threat title | Obtaining refresh token from authorization server database, IETF RFC 6819 [i.8], clause 4.5.2 | +| Threat description | This threat is applicable if the authorization server stores refresh tokens as handles in a database. An attacker may obtain refresh tokens from the authorization server's database by gaining access to the database or launching a SQL injection attack. | +| Threat type | Information Disclosure | +| Impact type | Authorization | +| Affected Asset | OAuth authorization server | + +# 7 Risk Assessment + +# 8 Security Controls + +# 9 OAuth 2.0 Authorization framework + +## 9.1 Overview + +Figure 9.1 depicts the basic OAuth 2.0 framework for O-RAN Architecture elements and applications. This general authorization framework is generalized from clause 1 of IETF RFC 6749 [i.5]. + +![Diagram of the ORAN OAuth 2.0 Framework showing the interaction between the O-RAN Client, Resource Owner, Authorization Server, and Resource Server.](a5ed9f7893313da659648a481972e515_img.jpg) + +``` + +sequenceDiagram + participant Client as O-RAN Client + participant RO as Resource Owner + participant AS as Authorization Server + participant RS as Resource Server + + Client->>RO: 1. O-RAN Client Authorization Request + RO-->>Client: 2. Resource Owner Authorization Grant + Client->>AS: 3. O-RAN Client Authorization Grant + AS-->>Client: 4. Authorization Server Access Token + Client->>RS: 5. O-RAN Client Access Token + RS-->>Client: 6. Protected Resource + +``` + +The diagram illustrates the ORAN OAuth 2.0 Framework. It shows the O-RAN Client interacting with three external entities: the Resource Owner, the Authorization Server, and the Resource Server. The process follows six steps: 1. O-RAN Client Authorization Request (Client to Resource Owner), 2. Resource Owner Authorization Grant (Resource Owner to Client), 3. O-RAN Client Authorization Grant (Client to Authorization Server), 4. Authorization Server Access Token (Authorization Server to Client), 5. O-RAN Client Access Token (Client to Resource Server), and 6. Protected Resource (Resource Server to Client). + +Diagram of the ORAN OAuth 2.0 Framework showing the interaction between the O-RAN Client, Resource Owner, Authorization Server, and Resource Server. + +Figure 9.1-1 OAuth 2.0 framework for O-RAN Architecture elements and applications + +O-RAN OAuth 2.0 framework defines four roles from clause 1 of IETF RFC 6749 [i.5]: + +- O-RAN client: An O-RAN client is an O-RAN Architecture Element or Application like an rApp or xApp acting as an OAuth client. +- Authorization server: The server issuing access tokens to the O-RAN client after successfully authenticating the resource owner and obtaining authorization. + +- Resource owner: “An entity capable of granting access to a protected resource. When the resource owner is a person, it is referred to as an end-user.” ([i.5], clause 1.1) +- Resource server: “The server hosting the protected resources, capable of accepting and responding to protected resource requests using access tokens.” ([i.5], clause 1.1) + +## 9.2 Key Issues + +### 9.2.1 Key Issue #1: Registration of O-RAN Architecture Elements in OAuth Authorization Server + +#### 9.2.1.1 Key issue detail + +This key issue addresses the security threats during the registration of O-RAN client (e.g., xApp, rApp) in the authorization server. + +#### 9.2.1.2 Security threats + +| | | +|--------------|------------------------------------------------------| +| T-OAuth-G-12 | Accidental exposure of passwords at client site | +| T-OAuth-G-06 | Open redirectors on client | +| T-OAuth-G-05 | Disclosure of client credentials during transmission | + +### 9.2.2 Key Issue #2: Provisioning of Client ID and secrets to O-RAN Architecture Elements + +#### 9.2.2.1 Key issue detail + +This key issue addresses the security threats while provisioning the client ID and secrets for O-RAN client (e.g., xApp, rApp). + +#### 9.2.2.2 Security threats + +| | | +|---------------|-------------------------------------------------------------| +| T-OAuth-G-01 | Obtaining client secrets | +| T-OAuth-G-03 | Obtaining access tokens | +| T-OAuth-G-04 | Eavesdropping access tokens | +| T-OAuth-G-05 | Disclosure of client credentials during transmission | +| T-OAuth-G-09 | Access token leak in transport/endpoints | +| T-OAuth-G-18 | Guessing access tokens | +| T-OAuth-G-19 | Access token phishing by counterfeit resource server | +| T-OAuth-G-20 | Abuse of token by legitimate resource server or client | +| T-OAuth-G-21 | Token leakage via log files and http referrers | +| T-OAuth-AS-10 | Obtaining user passwords from authorization server database | + +### 9.2.3 Key Issue #3: Provisioning of Authorization Grants for O-RAN Architecture Elements + +#### 9.2.3.1 Key issue detail + +This key issue addresses the security threats while provisioning the authorization grants for O-RAN client (e.g., xApp, rApp). + +#### 9.2.3.2 Security threats + +| | | +|--------------|-------------------------------------------------------------------------------------| +| T-OAuth-G-08 | Obtaining authorization by code substitution (OAuth Login) | +| T-OAuth-G-10 | Malicious client obtains existing authorization by fraud | +| T-OAuth-G-11 | Malicious client obtains authorization | +| T-OAuth-G-13 | Client obtains scopes without end-user authorization and possible misconfigurations | + +### 9.2.4 Key Issue #4: Revocation of Client ID and secrets for O-RAN Architecture Elements + +#### 9.2.4.1 Key issue detail + +This key issue addresses the security threats related to revocation of client ID and secrets for O-RAN client (e.g., xApp, rApp). + +#### 9.2.4.2 Security threats + +| | | +|---------------|--------------------------------------------------------------| +| T-OAuth-G-02 | Obtaining refresh tokens | +| T-OAuth-G-14 | Client obtains refresh token through automatic authorization | +| T-OAuth-G-15 | Eavesdropping refresh tokens from authorization server | +| T-OAuth-G-17 | Refresh token phishing by counterfeit authorization server | +| T-OAuth-AS-11 | Obtaining refresh token from authorization server database | + +### 9.2.5 Key Issue #5: Revocation of Authorization Grants for O-RAN Architecture Elements + +#### 9.2.5.1 Key issue detail + +This key issue addresses the security threats related to revocation of authorization grants for O-RAN client (e.g., xApp, rApp). + +#### 9.2.5.2 Security threats + +| | | +|---------------|----------------------------------------------------------| +| T-OAuth-AS-07 | Resource owner impersonation | +| T-OAuth-AS-04 | Online guessing of authorization codes | +| T-OAuth-G-10 | Malicious client obtains existing authorization by fraud | + +### 9.2.6 Key Issue #6 Secure transfer of client secrets to clients + +#### 9.2.6.1 Key issue detail + +The need is to identify + +- How the client secrets are transferred to potential clients +- Whether the client secrets will be known at development time or runtime? + +#### 9.2.6.2 Security threats + +| | | +|---------------|------------------------------------------------------------| +| T-OAuth-G-01 | Obtaining client secrets | +| T-OAuth-G-05 | Disclosure of client credentials during transmission | +| T-OAuth-AS-01 | Password phishing by counterfeit authorization server | +| T-OAuth-G-12 | Accidental exposure of passwords at client site | +| T-OAuth-AS-03 | Obtaining client secret from authorization server database | + +### 9.2.7 Key Issue #7: Secure transit and storage of access and refresh tokens + +#### 9.2.7.1 Key issue detail + +It needs to be identified what possible mechanisms exists to ensure the integrity and confidentiality of access and refresh tokens. + +#### 9.2.7.2 Security threats + +| | | +|--------------|--------------------------------------------------------| +| T-OAuth-G-02 | Obtaining refresh tokens | +| T-OAuth-G-03 | Obtaining access tokens | +| T-OAuth-G-04 | Eavesdropping access tokens | +| T-OAuth-G-20 | Access token leak in transport/endpoints | +| T-OAuth-G-15 | Eavesdropping refresh tokens from authorization server | +| T-OAuth-G-16 | Obtaining refresh token by online guessing | +| T-OAuth-G-18 | Guessing access tokens | + +### 9.2.8 Key Issue #8: Defining expiration times for access tokens and client secrets + +#### 9.2.8.1 Key issue detail + +It needs to be identified if + +- Access tokens need to be configured with the minimal expiration time and in what use cases +- Client secrets needs to be revoked and refreshed regularly and if so at what intervals + +#### 9.2.8.2 Security threats + +| | | +|---------------|------------------------------------------------------------| +| T-OAuth-AS-01 | Password phishing by counterfeit authorization server | +| T-OAuth-G-10 | Malicious client obtains existing authorization by fraud | +| T-OAuth-AS-02 | Obtaining access tokens from authorization server database | +| T-OAuth-AS-03 | Obtaining client secret from authorization server database | + +### 9.2.9 Key Issue #9: Consumers based on Client\_IDs created with valid administration + +#### 9.2.9.1 Key issue detail + +It needs to be identified if + +- Consumers who connect are only those validated by administrators +- Dynamic clients are possible or not + +#### 9.2.9.2 Security threats + +| | | +|--------------|----------------------------------------| +| T-OAuth-G-11 | Malicious client obtains authorization | +|--------------|----------------------------------------| + +### 9.2.10 Key Issue #10: Scope creation + +#### 9.2.10.1 Key issue detail + +It needs to be checked as to how scopes are designed, provisioned and enforced. Key topics are + +- How scopes are designed by the resource servers including the clearance and access levels +- How scopes are transferred the authorization server +- How scopes are requested by the client +- How scopes are created in the authorization server + +#### 9.2.10.2 Security threats + +| | | +|-------------|-------------------------------------------------------------------------------------| +| T-Auth-G-11 | Malicious client obtains authorization | +| T-Auth-G-13 | Client obtains scopes without end-user authorization and possible misconfigurations | + +### 9.2.11 Key Issue #11: Need to support RBAC (Role Based Access Control) for the O-RAN resource servers + +The O-RAN resource servers need to be accessed by only those users who are authorized to carry out the specific task. Hence, we need a mechanism to design and map the O-RAN resource server to the users for access control. + +#### 9.2.11.1 Key issue detail + +It needs to be checked as to + +- How to limit the access of resources to specified users (least privilege) and only for the intended task. +- How to manage access (assign users to permissions related to the resource servers) in a fast and efficient manner. +- How to retain a role only for the period of time required and no longer. + +#### 9.2.11.2 Security threats + +The threats related to limited access control are below. + +- Malicious attacks with open access to the entire system of assets and data +- Insider threats +- Privilege stagnation over a period of time + +Editor notes: Some of the threats id's such as T-O-RAN-03,T-O-RAN-06,T-R1-01,T-R1-05,T-AppLCM-04,T-GEN-02,T-SMO-10 in clause 5.4 of the present document are mapped and identified in the O-RAN Threat Modelling and Remediation Analysis document [i.20], need to be discussed further. + +### 9.2.12 Key Issue #12: Need to support secure transmission of request and response between client and authorization server, between client and resource server + +The O-RAN related HTTP client (e.g.: R1, A1, O2) need to make a request to the authorization server and receive a response with respect to the access token. After that the access token has to be transferred from the client to the resource server. + +#### 9.2.12.1 Key issue detail + +It needs to be checked as to + +- How the client will send request details including credentials related to client\_id and client\_secret to the authorization server +- How the client will receive the response from the authorization server +- How the client will send the access token to the resource server + +#### 9.2.12.2 Security threats + +The threats related to insecure transmission of request and response are + +| | | +|--------------|------------------------------------------------------| +| T-OAuth-G-01 | Obtaining client secrets | +| T-OAuth-G-03 | Obtaining access tokens | +| T-OAuth-G-05 | Disclosure of client credentials during transmission | + +## 9.3 Solutions + +### 9.3.1 Solution #1: Registration of rApp + +#### 9.3.1.1 Background + +This use case allows an rApp to register to the SMO as specified in R1GAP [i.13] [i.14]. The registration procedure is specified as part of Service Management and Exposure services in R1GAP [i.13] [i.14]. + +#### 9.3.1.2 Solution Description + +Table 9.3.1-1 rApp Registration use case + +| Use Case Stage | Evolution / Specification | <>
    Related use | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | 1) Register the rApp to the SME services Producer in SMO framework. | | +| Actors and Roles |
    • - rApp in the role of Service Producer and/or Service Consumer
    • - SME in the role of SME services Producer.
    | | +| Assumptions | n/a | | +| Preconditions | The rApp is instantiated. | | +| Begins when | The rApp Management SMOS is ready for registration. | | +| Step 1 (M) | The rApp Management SMOS sends a registration request to the SME in the SMO passing relevant information needed. | | +| Step 1 (M) | The SME process the rApp registration request that may include.
    • - performing authentication,
    • - if rApp is authenticated, rAppId will be assigned to rApp.
    | | +| Step 3 (M) | Response to the registration request along with the rAppId. | | +| Ends when | The rApp is allocated with an rAppId. | | +| Exceptions | n/a | | +| Post Conditions | The rApp is registered with the SMO framework and an rAppId is allocated to the rApp. | | +| Traceability | REQ-R1-SME-rAppreg-FUN1, REQ-R1-SME-rAppreg-FUN2. | | + +``` + +@startuml + skinparam ParticipantPadding 5 + skinparam BoxPadding 10 + skinparam defaultFontSize 12 + skinparam lifelineStrategy solid + autonumber + box "SMO" #cadetBlue + participant "rApp Management SMOS" as rApp_M + participant "SME (SMOS)" as SME + +``` + +``` + +rApp_M -> SME:App Manager sends a registration request \n to the SME service based on endpoint +details \n and passing relevant information needed +SME->SME : +note right +Registration processing +assign rAppid using +Authorization service +end note +SME -> rApp_M :Response to the registration request (rAppid) + +Note Over rApp_M +rApp Management assign +rAppid to rApp as per +App LCM process +end note +endbox +@enduml + +``` + +![Sequence diagram for rApp Registration use case within the SMO. The diagram shows two lifelines: rApp Management SMOS and SME(SMOS). Step 1: rApp Management SMOS sends a registration request to SME(SMOS). Step 2: SME(SMOS) performs internal processing (Registration processing, assign rAppid using Authorization service). Step 3: SME(SMOS) sends a response (Response to the registration request (rAppid)) back to rApp Management SMOS. A note at the bottom indicates that rApp Management assigns the rAppid to rApp as per the App LCM process.](ab94b23269a03a4310fc4b669f8679cd_img.jpg) + +``` + +sequenceDiagram + box SMO + participant rAppM as rApp Management SMOS + participant SME as SME(SMOS) + end + rAppM->>SME: 1 App Manager sends a registration request to the SME service based on endpoint details and passing relevant information needed + Note right of SME: 2 Registration processing assign rAppid using Authorization service + SME->>SME: + SME->>rAppM: 3 Response to the registration request (rAppid) + Note over rAppM: rApp Management assign rAppid to rApp as per App LCM process + +``` + +Sequence diagram for rApp Registration use case within the SMO. The diagram shows two lifelines: rApp Management SMOS and SME(SMOS). Step 1: rApp Management SMOS sends a registration request to SME(SMOS). Step 2: SME(SMOS) performs internal processing (Registration processing, assign rAppid using Authorization service). Step 3: SME(SMOS) sends a response (Response to the registration request (rAppid)) back to rApp Management SMOS. A note at the bottom indicates that rApp Management assigns the rAppid to rApp as per the App LCM process. + +Figure 9.3.1-1 rApp Registration use case sequence diagram + +#### 9.3.1.3 Impacts on Existing O-RAN Architecture Elements and Interfaces + +R1 interface, rApp and SME are the O-RAN architecture elements and interfaces involved in the proposed use cases as specified in Decoupled SMO [i.15] [i.16]. + +##### 1) Service Management and Exposure (SME) SMOS + +The SME service is introduced in the [i.8] clause 3.1. While the SME was initially targeted for management and exposure of rApp services in the [i.8], its services are applicable to any entities within the SMO that fulfil the roles of Service Producer and/or Service Consumer. + +In a decomposed service-based SMO architecture, the SME can be leveraged as a generic SMOS, handling service management and exposure for any SMOSs within SMO. The SME SMOS provides a set of common SMO capabilities that are needed for all SMO Services. + +Several of the SME services are applicable to any SMOSs: + +- SMOS registration, +- SMOS discovery, +- Authentication and authorization to access a SMOS, +- Communication support between SMOS Service Producers and SMOS Service Consumers (SMOS Communication), +- Bootstrap of new SMOSs (optional), +- Heartbeat of SMOSs (optional). + +##### 2) rApp Management (SMOS) + +The rApp management service handles management aspects specific to rApps such as: + +- rApp Configuration Management (CM): enables management of the rApp configuration settings, +- rApp Performance Management (PM): offers support for performance reporting on an rApp performance, or of the rApp communication with the non-RT RIC framework (rApp usage of R1 interface), +- rApp Fault Management (FM): provides the fault reporting capabilities to rApps, so they can consume it to report faults that are related to the rApp, or to the rApp communication with the non-RT RIC framework (rApp usage of R1 interface), +- rApp Logging Information: enables rApps to convey their logging information to the non-RT RIC framework, +- rApp lifecycle management services, that expose services that allow to trigger rApp software lifecycle management. + +#### 9.3.1.4 Solution Evaluation + +Key Issue #1: Registration of O-RAN Architecture Elements in OAuth authorization server + +#### 9.3.1.5 Potential Security Recommendations + +- OAuth protection of the R1 interface is already mandatory in the O-RAN Security Requirements and Controls Specifications [i.2] SEC-CTL-R1-3. + +### 9.3.2 Solution #2: Request access token for R1 services + +#### 9.3.2.1 Background + +This use case allows an rApp to request an access token for access to R1 services as specified in R1GAP [i.13] [i.14]. The request access procedure is specified as part of Service Management and Exposure services in R1GAP [i.13] [i.14]. + +An rApp in the role of Service Consumer will be able to request the token and once the token is available, the rApp in the role of Service Consumer will be able access the R1 Services for which it has been authorized. + +#### 9.3.2.2 Solution Description + +Table 9.3.2-1 Request access token for R1 services use case + +| Use case stage | Evolution / specification | <> Related use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| +| Goal | To enable rApp to request an access token for access to R1 services. | | +| Actors and Roles | rApp in the role of Service Consumer that requests token for access to R1 services.
    SME as SMOS in the role of SME services Producer support authorization service | | +| Assumptions | rAppId and credentials have been provisioned. | | +| Pre-conditions | R1 interface is established | | +| Begins when | rApp has determined need for an access token to access R1 services and resources. | | +| Step 1 (M) | rApp sends Access token request containing the rAppId and optionally token scope. | SPS [i.1], clause 4.7.2.3 | +| Step 2 (M) | SME authenticate the rApp and if the rApp token request is authorized, then an access token is generated. | SPS [i.1], clause 4.7.2.3 | +| Step 3 (M) | SME respond with access token. | SPS [i.1], clause 4.7.2.3 | +| Ends when | rApp has received an access token for access to R1 services. | | +| Exceptions | n/a | | +| Post-conditions | The rApp is authorized for accessing R1 services. | | +| Traceability | REQ-R1-A-FUN1 | | + +``` + +@startuml + skinparam ParticipantPadding 5 + skinparam BoxPadding 10 + skinparam defaultFontSize 12 + skinparam lifelineStrategy solid + autonumber + box "non-RT RIC" #whitesmoke + box #ivory + participant rApp as rApp + endbox + box "SMO" #cadetBlue + participant "SME (SMOS)" as SME + endbox + rApp -> SME: <> Access token request (rAppId) + SME->SME: + note right + Check Authorization + (Authenticate the rApp and + check if authorized, if + rApp is authorized, + generate an access token) + end note + + SME -> rApp :<> Access token response (access token) + @enduml + +``` + +![Sequence diagram for Request access token for R1 services. The diagram shows two lifelines: rApp (on the left) and SME (SMOS) (on the right). Step 1: rApp sends a message '1 <> Access token request (rAppId)' to SME (SMOS). Step 2: SME (SMOS) performs a self-call '2' with a note: 'Check Authorization (Authenticate the rApp and check if authorized, if rApp is authorized, generate an access token)'. Step 3: SME (SMOS) sends a message '3 <> Access token response (access token)' back to rApp.](282ffbe52f9212cc1316956ea9eb7292_img.jpg) + +``` + +sequenceDiagram + participant rApp + participant SME as SME (SMOS) + Note over rApp: 1 <> Access token request (rAppId) + rApp->>SME: + Note over SME: 2 Check Authorization (Authenticate the rApp and check if authorized, if rApp is authorized, generate an access token) + SME-->>SME: + Note over SME: 3 <> Access token response (access token) + SME-->>rApp: + +``` + +Sequence diagram for Request access token for R1 services. The diagram shows two lifelines: rApp (on the left) and SME (SMOS) (on the right). Step 1: rApp sends a message '1 <> Access token request (rAppId)' to SME (SMOS). Step 2: SME (SMOS) performs a self-call '2' with a note: 'Check Authorization (Authenticate the rApp and check if authorized, if rApp is authorized, generate an access token)'. Step 3: SME (SMOS) sends a message '3 <> Access token response (access token)' back to rApp. + +Figure 9.3.2-1 Request access token for R1 services use case sequence diagram + +#### 9.3.2.3 Impacts on Existing O-RAN Architecture Elements and Interfaces + +R1 interface, rApp and SME are the O-RAN architecture elements and interfaces involved in the proposed use cases as specified in Decoupled SMO [i.15] [i.16]. + +##### 1) Service Management and Exposure (SME) SMOS + +The SME service is introduced in the [i.8] clause 3.1. While the SME was initially targeted for management and exposure of rApp services in the [i.8], its services are applicable to any entities within the SMO that fulfil the roles of Service Producer and/or Service Consumer. + +In a decomposed service-based SMO architecture, the SME can be leveraged as a generic SMOS, handling service management and exposure for any SMOSs within SMO. The SME SMOS provides a set of common SMO capabilities that are needed for all SMO Services. Several of the SME services are applicable to any SMOSs: + +- SMOS registration, +- SMOS discovery, +- Authentication and authorization to access a SMOS, +- Communication support between SMOS Service Producers and SMOS Service Consumers (SMOS Communication), +- Bootstrap of new SMOSs (optional), +- Heartbeat of SMOSs (optional). + +##### 2) SME functions in the role of SME services Producer + +- supports the functionality of OAuth 2.0 authorization server, +- support authentication and authorization of an rApp to determine which R1 services an rApp can access, +- provide response of success or failure to access token request. + +##### 3) rApp + +- supports initiating the procedure to request access token, +- supports initiating service request with the available access token. + +#### 9.3.2.4 Solution Evaluation + +Key Issue #3: Provisioning of Authorization Grants for R1 services + +#### 9.3.2.5 Potential Security Recommendation + +- Use OAuth 2.0, as specified in O-RAN Security Protocols Specifications [i.1], clause 4.7 to implement authorization in the R1 interface. +- Enable rApp to request OAuth 2.0 access tokens for R1 services. +- Enable the SME to act as both an OAuth 2.0 resource and an OAuth 2.0 authorization server. + +### 9.3.3 Solution #3: R1 services request with access token + +#### 9.3.3.1 Background + +This use case discusses R1 service Producer to verify that rApp is authorized to access the R1 service as specified in R1GAP [i.13] [i.14]. The service request procedure is specified as part of Service Management and Exposure services in R1GAP [i.13][i.14]. + +#### 9.3.3.2 Solution Description + +Table 9.3.3-1 R1 Service request using access token use case + +| Use case stage | Evolution / specification | <> Related use | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| +| Goal | To enable R1 service Producer to verify that rApp is authorized to access the R1 service. | | +| Actors and Roles | rApp in the role of Service Consumer that requests access to an R1 service with access token.
    R1 service producer in the role of SME services Producer that supports the validation of the access token and provides access to the requested service. | | +| Assumptions | rApp has requested and received an access token for the R1 service for which service access is requested. | | +| Pre-conditions | R1 interface is established. | | +| Begins when | rApp initiates a request for an R1 Service to R1 Service producer. | | +| Step 1 (M) | rApp sends service request containing an access token to R1 service Producer | | +| Step 2 (M) | R1 service Producer verifies integrity and claims in the access token. If successful, the requested service is executed. | SPS [i.1] clause 4.7.2.4] | +| Step 3 & 4 (M) | R1 service Producer sends response to the service request if it has valid token | | +| Step 5 & 6 (O) | The verification of integrity and claims in step 3 was unsuccessful due to invalid or expired token, the requested service is not executed, and R1 service Producer sends a response with appropriate error code. | | +| Ends when | R1 service Producer has responded to the service request. | | +| Post-conditions | - | | +| Traceability | REQ-R1-SME-A-FUN2 | | + +``` + +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid + +``` + +``` + +autonumber +box #whitesmoke + box #ivory + participant rApp as rApp +endbox + box "SMO" #cadetBlue + participant " SME " as SME + participant " R1 service Producer m" as SP +endbox + +rApp->SP: <> Service request (access token) +SP->SP +note right + Validate token + (Verify integrity and claims + in the access token. + If successful, execute + the requested service). +end note +alt +SP->SP: Valid Token +SP -> rApp :<> Service response (success) +SP->SP: Invalid or Expired Token +SP -> rApp :<> Service response (failure) +end ref +@enduml + +``` + +![Sequence diagram for R1 Service request using access token. The diagram shows three lifelines: rApp (yellow), SME (teal), and R1 service Producer (teal). The SMO box contains SME and R1 service Producer. Step 1: rApp sends 'Service request (access token)' to R1 service Producer. Step 2: R1 service Producer performs a self-call 'Validate token (Verify integrity and claims in the access token. If successful, execute the requested service)'. An 'alt' block follows: Step 3: R1 service Producer sends 'Valid Token' to SME. Step 4: SME sends '<> Service response (success)' to rApp. Step 5: R1 service Producer sends 'Invalid or Expired Token' to SME. Step 6: SME sends '<> Service response (failure)' to rApp.](869c5b22b3730d8e406a3238074edd3f_img.jpg) + +``` + +sequenceDiagram + participant rApp + participant SME + participant R1 as R1 service Producer + alt SMO + SME + R1 + end + + rApp->>R1: 1 <> Service request (access token) + activate R1 + R1->>R1: 2 Validate token +(Verify integrity and claims +in the access token. +If successful, execute +the requested service). + alt alt + R1->>SME: 3 Valid Token + SME->>rApp: 4 <> Service response (success) + else alt + R1->>SME: 5 Invalid or Expired Token + SME->>rApp: 6 <> Service response (failure) + end + end alt + +``` + +Sequence diagram for R1 Service request using access token. The diagram shows three lifelines: rApp (yellow), SME (teal), and R1 service Producer (teal). The SMO box contains SME and R1 service Producer. Step 1: rApp sends 'Service request (access token)' to R1 service Producer. Step 2: R1 service Producer performs a self-call 'Validate token (Verify integrity and claims in the access token. If successful, execute the requested service)'. An 'alt' block follows: Step 3: R1 service Producer sends 'Valid Token' to SME. Step 4: SME sends '<> Service response (success)' to rApp. Step 5: R1 service Producer sends 'Invalid or Expired Token' to SME. Step 6: SME sends '<> Service response (failure)' to rApp. + +Figure 9.3.3-1 R1 Service request using access token use case sequence diagram + +#### 9.3.3.3 Impacts on Existing O-RAN Architecture Elements and Interfaces + +R1 interface, rApp and SME are the O-RAN architecture elements and interfaces involved in the proposed use cases as specified in Decoupled SMO [i.15] [i.16]. + +##### 1) Service Management and Exposure (SME) SMOS + +The SME service is introduced in the [i.13] clause 3.1. While the SME was initially targeted for management and exposure of rApp services in the [i.13], its services are applicable to any entities within the SMO that fulfil the roles of Service Producer and/or Service Consumer. + +In a decomposed service-based SMO architecture, the SME can be leveraged as a generic SMOS, handling service management and exposure for any SMOSs within SMO. The SME SMOS provides a set of common SMO capabilities that are needed for all SMO Services. + +Several of the SME services are applicable to any SMOSs: + +- SMOS registration, +- SMOS discovery, +- Authentication and authorization to access a SMOS, +- Communication support between SMOS Service Producers and SMOS Service Consumers (SMOS Communication), +- Bootstrap of new SMOSs (optional), +- Heartbeat of SMOSs (optional). + +##### 2) SME in the role of SME services Producer + +- supports the functionality of OAuth 2.0 authorization server, +- support authentication and authorization of an rApp to determine which R1 services an rApp can access, +- provide response of success or failure to access token request + +##### 3) rApp + +- initiating the procedure to request access token, +- initiating service request with the available access token. + +##### 4) R1 Service Producer + +- provider of an R1 service. + +#### 9.3.3.4 Solution Evaluation + +Key issue #6: Provisioning of service access based on access token + +#### 9.3.3.5 Potential Security Recommendations + +- Use OAuth 2.0, as specified in O-RAN Security Protocols Specifications [i.1], clause 4.7 to implement authorization in the R1 interface. +- Enable the SME to act as both an OAuth 2.0 resource and an OAuth 2.0 authorization server. + +### 9.3.4 Solution #4: Secure transmission of request and response between client to authorization server, between client and resource server for R1, A1 and O2 + +#### 9.3.4.1 Background + +This solution elaborates on the possibilities to ensure that data for the below flows is secure during transmission, + +1. Between client and authorization server + - a. The client needs to send the credentials and the authorization request details which need to be secured during transmission. +2. Between client and resource server + - a. The client needs to send the access token to the authentic resource server which needs to be secured during transmission. + +#### 9.3.4.2 Solution Description + +Table 9.3.4-1 use case of secure data transmission between client and authorization server + +| Use Case Stage | Evolution / Specification | <>
    Related use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | 1) Transfer the data from client to authorization server securely | | +| Actors and Roles | Below are examples of HTTP clients
    • - rApp in the role of R1 Service Consumer
    • - SMO towards near RT RIC in the role of A1 consumer
    • - O-RAN assets towards O-cloud in the role of O2 consumer
    | | +| Assumptions | TLS is the underlying secure protocol on which the below is built upon. | | +| Preconditions | The consumer is registered with valid client_id and client_secret
    The authorization server has a valid X.509 certificate
    The consumer has the trust anchor for the authorization server's X.509 certificate | | +| Begins when | The consumer needs to contact the authorization server to send an authorization request | | +| Step 1 (M) | The client authenticates to the authorization server | | +| Step 2 (M) | The client sends the request details to authorization server after successful authentication | | +| Ends when | The consumer receives the access token from the authorization server | | +| Exceptions | n/a | | +| Post Conditions | The consumer is in possession of the access token securely | | +| Traceability | n/a | | + +``` + +@startuml +hide footbox +skinparam sequenceActorBackgroundColor White +skinparam sequenceActorBorderColor Black +skinparam sequenceParticipantBackgroundColor White +skinparam sequenceParticipantBorderColor Black +skinparam sequenceArrowColor Black +skinparam sequenceLifeLineBackgroundColor White +skinparam sequenceLifeLineBorderColor Black +skinparam shadowing false +skinparam NoteBackgroundColor White +skinparam NoteBorderColor Black + +Title Secure transmission between client and authorization server +Actor "client" as client +participant "OAuth Authorization Server" as AS + +client -> AS:authenticate with client_id and client_secret +client -> AS:send authorization Request +AS -> client: send access token + +``` + +@endum1 + +##### Secure transmission between client and authorization server + +![Sequence diagram showing secure transmission between a client and an OAuth Authorization Server. The client sends 'authenticate with client_id and client_secret', then 'send authorization Request'. The server responds with 'send access token'.](a9f92f13a8587924d496f455cadf59d9_img.jpg) + +``` + +sequenceDiagram + actor client + participant OAuth as OAuth Authorization Server + client->>OAuth: authenticate with client_id and client_secret + client->>OAuth: send authorization Request + OAuth-->>client: send access token + +``` + +Sequence diagram showing secure transmission between a client and an OAuth Authorization Server. The client sends 'authenticate with client\_id and client\_secret', then 'send authorization Request'. The server responds with 'send access token'. + +Figure 9.3.4-1 Transmission between client and authorization server + +``` + +@startuml +hide footbox +skinparam sequenceActorBackgroundColor White +skinparam sequenceActorBorderColor Black +skinparam sequenceParticipantBackgroundColor White +skinparam sequenceParticipantBorderColor Black +skinparam sequenceArrowColor Black +skinparam sequenceLifeLineBackgroundColor White +skinparam sequenceLifeLineBorderColor Black +skinparam shadowing false +skinparam NoteBackgroundColor White +skinparam NoteBorderColor Black + +Title Secure transmission between client and resource server +Actor "client" as client +participant "resource server" as RS + +client <-> RS:mutual authentication +client -> RS:send access token as part of API operation + +@enduml + +``` + +##### Secure transmission between client and resource server + +![Sequence diagram showing secure transmission between a client and a resource server. The client and server perform 'mutual authentication', and then the client sends 'send access token as part of API operation' to the server.](e624c48fdf2ecdb2564d6d46a233e72b_img.jpg) + +``` + +sequenceDiagram + actor client + participant resource as resource server + client <-> resource: mutual authentication + client->>resource: send access token as part of API operation + +``` + +Sequence diagram showing secure transmission between a client and a resource server. The client and server perform 'mutual authentication', and then the client sends 'send access token as part of API operation' to the server. + +Figure 9.3.4-2 Transmission between client and resource server + +##### 9.3.4.2.1 Authentication methods between client, authorization server and resource server + +The solutions below are various options to transfer the information securely between the O-RAN OAuth clients and the various servers in the interaction including the authorization server and the various O-RAN resource servers. + +Below is a summary: + +Table 9.3.4-2 Authentication methods + +| OAuth token end point authentication method | Reference | Short description | +|---------------------------------------------|--------------------------|--------------------------------------------------------------------------------------------------------------------------------| +| Tls_client_auth | RFC 8705 [i.6] | Usage of certificates for both client and server authentication. Usage of certificate hash for certificate bound access tokens | +| Private_key_JWT (with JWE) | RFC 8705 [i.6] | Usage of certificates for both integrity and confidentiality protection (encryption) | +| Private_key_JWT | OpenID foundation [i.21] | Usage of certificates for integrity protection | +| Client_secret_JWT | OpenID foundation [i.21] | Usage of shared secret for example client_secret for integrity protection | +| Client_secret_basic | RFC 7591 [i.22] | Client_id and client_secret transmission in the header | +| Client_secret_post | RFC 7591 [i.22] | Client_id and client_secret transmission in the payload | +| Self_signed_tls_client_auth | RFC 8705 [i.6] | Usage of client side self signed certificates in mutual authentication | + +Below are the details of the methods explained above + +- 1) Tls\_client\_auth + - a. Part of RFC 8705 + - b. Mutual authentication of both client and server. Here certificates are issued by a certificate authority. Also supports token binding. + - c. For certificate bound access tokens every party proves that they are in possession of their private key. + - d. Who is in possession of the private key used to establish the connection can use the access token (puts the hash of the certificate (cnf) that has been used) + +![Figure 9.3.4-3: Tls_client_OAuth method diagram. A client and an OAuth server establish a Mutual TLS connection. The client then sends a request to a Resource server, which responds with a token. The token structure is shown as a JSON object: { 'alg': 'RS256', 'client_id': 'abc123', 'nonce': '', 'signature' }.](94220bb4f68889783b714d2c1e688efd_img.jpg) + +Figure 9.3.4-3: Tls\_client\_OAuth method diagram. A client and an OAuth server establish a Mutual TLS connection. The client then sends a request to a Resource server, which responds with a token. The token structure is shown as a JSON object: { 'alg': 'RS256', 'client\_id': 'abc123', 'nonce': '', 'signature' }. + +Figure 9.3.4-3 - Tls\_client\_OAuth method + +###### 2) Private\_key\_JWT (with JWE) + +- Part of OpenID foundation specification +- Public and private key is used to sign and encrypt the JWT token using asymmetric cryptography. +- Contents of the message cannot be seen as they are encrypted + +![Figure 9.3.4-4: Private_key_JWT with JWE method diagram. A client sends a request to an OAuth server. The request body is a POST /token with Client_assertion_URI=, client_assertion_. The JWT token structure is shown as a JSON object: { 'Header', 'Encrypted key', 'Initialisation vector', 'Ciphertext (encrypted JWS)', 'Authentication tag' }.](5f19af628e407fc47cc229cb28b0c74d_img.jpg) + +Figure 9.3.4-4: Private\_key\_JWT with JWE method diagram. A client sends a request to an OAuth server. The request body is a POST /token with Client\_assertion\_URI=, client\_assertion\_. The JWT token structure is shown as a JSON object: { 'Header', 'Encrypted key', 'Initialisation vector', 'Ciphertext (encrypted JWS)', 'Authentication tag' }. + +Figure 9.3.4-4 Private\_key\_JWT with JWE method + +###### 3) Private\_key\_JWT + +- Part of OpenID foundation specification +- The client\_id and client\_secret is part of the JWT token which is integrity protected. The JWT is a string which is attached as a client assertion. Here we AVOID putting the secret in message, instead in the JWT token. +- Confidential client create JSON Web Token along with the public and private key. Hence structure of the JWT is the header, body and the Signature. Hence JWS client has the private key and shares the public key to the authorization server for validation of the request. Hence the contents of the message can be seen but secure from manipulation. + +![Figure 9.3.4-5: Private_key_JWT method diagram. A client sends a request to an OAuth server. The request body is a POST /token with Client_assertion_type=, client_assertion_. The JWT token structure is shown as a JSON object: { 'alg': 'ES256', 'client_id': 'abc123', 'response_type': 'code', 'state': 'abc', 'redirect_uri': 'registered-redirect-uri', 'signature' }.](c2e33ca2a94cbb0b755f26440be1c0ca_img.jpg) + +Figure 9.3.4-5: Private\_key\_JWT method diagram. A client sends a request to an OAuth server. The request body is a POST /token with Client\_assertion\_type=, client\_assertion\_. The JWT token structure is shown as a JSON object: { 'alg': 'ES256', 'client\_id': 'abc123', 'response\_type': 'code', 'state': 'abc', 'redirect\_uri': 'registered-redirect-uri', 'signature' }. + +Figure 9.3.4-5 Private\_key\_JWT method + +###### 4) Client\_secret\_JWT + +- a. Part of OpenID foundation specification +- b. Client\_secret\_JWT - client\_id and client\_secret in the JWT token which is integrity protected with a shared secret key (client\_secret known to both parties) using HMAC. The JWT is a string which is attached as a client assertion. Here we AVOID putting the secret in message. Instead in the JWT token which is with a MAC (hash function+Secret) + +![Diagram of Client_secret_JWT method showing a client sending a JWT token to an OAuth server. The JWT token has a header and a body. The body contains client_assertion_type and client_assertion. The client_assertion is a JWT token with a header (alg: RS256) and a body (client_id, response_type, state, redirect_uri, and MAC).](721fd8bad03ea911b51744d701b1a4aa_img.jpg) + +The diagram illustrates the Client\_secret\_JWT method. A client sends a message to an OAuth server. The message consists of a Header and a Body. The Body contains 'Post /token' and 'Client\_assertion\_type=, client\_assertion\_'. The client\_assertion\_ is a JWT token with a header (alg: RS256) and a body (client\_id: abc123, response\_type: code, state: abc, redirect\_uri: registered-URI, and MAC). + +Diagram of Client\_secret\_JWT method showing a client sending a JWT token to an OAuth server. The JWT token has a header and a body. The body contains client\_assertion\_type and client\_assertion. The client\_assertion is a JWT token with a header (alg: RS256) and a body (client\_id, response\_type, state, redirect\_uri, and MAC). + +Figure 9.3.4-6 Client\_secret\_JWT method + +###### 5) Client\_secret\_basic + +client\_id and client\_secret in the header of the message + +- Defined in RFC 7591 + +![Diagram of Client_secret_basic method showing a client sending a message to an OAuth server. The message has a header (Authorization: Basic-Base64encoding) and a body.](e6b8f4a7741fa070925f6166666c1f20_img.jpg) + +The diagram illustrates the Client\_secret\_basic method. A client sends a message to an OAuth server. The message has a Header (Authorization: Basic-Base64encoding) and a Body. + +Diagram of Client\_secret\_basic method showing a client sending a message to an OAuth server. The message has a header (Authorization: Basic-Base64encoding) and a body. + +Figure 9.3.4-7 Client\_secret\_basic method + +###### 6) Client\_secret\_post + +client\_id and client\_secret in the body of the message + +- Defined in RFC 7591 + +![Diagram of Client_secret_post method showing a client sending a message to an OAuth server. The message has a header and a body containing .](0f7eaaf98898a601b19b7338053ec63f_img.jpg) + +The diagram illustrates the Client\_secret\_post method. A client sends a message to an OAuth server. The message has a Header and a Body containing . + +Diagram of Client\_secret\_post method showing a client sending a message to an OAuth server. The message has a header and a body containing . + +Figure 9.3.4-8 Client\_secret\_post method + +###### 7) Self\_signed\_tls\_client\_auth + +- a. RFC 8705 +- b. Mutual authentication using self signed certificates. Here certificate is created by self signing + +![Diagram illustrating the Self_signed_tls_client_auth method. A client (labeled 'Self signed') communicates with an OAuth server and a Resource server via Mutual TLS. The client sends a request to the OAuth server, which returns a response containing a token. The token is a JSON object with fields: 'alg': 'RS256', 'client_id': 'abc123', 'cnf': { 'X256': '', 'signature' }. The client then uses this token to access the Resource server.](359171a069930c765ab1263b2a654639_img.jpg) + +Diagram illustrating the Self\_signed\_tls\_client\_auth method. A client (labeled 'Self signed') communicates with an OAuth server and a Resource server via Mutual TLS. The client sends a request to the OAuth server, which returns a response containing a token. The token is a JSON object with fields: 'alg': 'RS256', 'client\_id': 'abc123', 'cnf': { 'X256': '', 'signature' }. The client then uses this token to access the Resource server. + +Figure 9.3.4-9 Self\_signed\_tls\_client\_auth method + +#### 9.3.4.3 Impacts on Existing O-RAN Architecture Elements and Interfaces + +R1 client, A1 client and the O2 client needs to choose the authentication method from the options explained above depending on the client and authorization server capabilities: + +#### 9.3.4.4 Solution Evaluation + +There is a need to support secure transmission of request and response between client and authorization server, between client to resource server. Below is the order of preference of various methods explained above in the order of most preferred to least preferred depending on the authorization server capabilities as well as the security level preferred. + +Table 9.3.4-3 Authentication method preferences + +| OAuth token end point authentication method | Evaluation | +|---------------------------------------------|------------------| +| Tls_client_auth | Highly preferred | +| Private_key_JWT (with JWE) | Preferred | +| Private_key_JWT | Preferred | +| Client_secret_JWT | Preferred | +| Client_secret_basic | Preferred | +| Client_secret_post | Preferred | +| Self_signed_tls_client_auth | Least preferred | + +#### 9.3.4.5 Potential Security Recommendations + +Editor's note: The security recommendation will be left for future study. + +### 9.3.5 Solution #5: Support for RBAC + +#### 9.3.5.1 Background + +- Role based access control is an important concept for the authorization mechanism in O-RAN to support either coarse grained or fine-grained access. +- The protected resources expose various operations which can be protected by access rules are mapped to different roles in an operator setup. An operator should assign roles to users (human and non-human) using identity management workflows. + +This solution elaborates on the possibilities to + +- Explain the association between the users, roles and the access rules (permissions) as defined in [i.19] clause 7. + +NOTE: the reference of the 3GPP specification in [i.19] can be considered as an example and customised for the O-RAN interfaces. + +#### 9.3.5.2 Solution Description + +Table 9.3.5-1 use case of RBAC + +| Use Case Stage | Evolution / Specification | <>
    Related use | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Design and deploy the role-based access model in an OAuth server for the O-RAN resources | | +| Actors and Roles | Admin resource server – design of operations on resource server for access control

    Admin – Network administrator for access control

    Authorization server | | +| Assumptions | Resources require coarse and fine grained permissions (access rules) to be designed

    The solution considers the possibility of adding the permissions manually. There is a possibility that this could also be automated | | +| Preconditions | n/a | | +| Begins when | Resource server needs to support access control | | +| Step 1 (M) | Design coarse grained and fine-grained permissions | | +| Step 2(M) | Express the permissions of a resource server | | +| Step 3(M) | Deploy permissions | | +| Step 4(M) | Deploy roles | | +| Step 5(M) | Deploy client_ID and its client_secret | | +| Ends when | Administration of RBAC is completed and resolved in the OAuth server | | +| Exceptions | n/a | | +| Post Conditions | n/a | | +| Traceability | n/a | | + +``` + +@startuml +hide footbox +skinparam sequenceActorBackgroundColor Whiteskinparam sequenceActorBorderColor Black +skinparam sequenceParticipantBackgroundColor White +skinparam sequenceParticipantBorderColor Black +skinparam sequenceArrowColor Black +skinparam sequenceLifeLineBackgroundColor White +skinparam sequenceLifeLineBorderColor Black +skinparam shadowing false + +``` + +``` + +skinparam NoteBackgroundColor White +skinparam NoteBorderColor Black + +Actor "Admin Resource server" as AR +Actor "Admin" +participant "Authorization Server" as AS + +group Design of permissions \n(resources and operations) +AR->> AR: 1: Design coarse grained and fine grained permissions +AR->> Admin: 2: Express the permissions of a resource server +end + +group Provisioning of RBAC model data +Admin ->> AS: 3: Deploy permissions +Admin ->> AS: 4: Deploy roles +Admin ->> AS: 5: Deploy client_ID and its Client_secret +end + +@enduml + +``` + +![UML sequence diagram for RBAC for client credentials. The diagram shows three lifelines: Admin Resource server (Actor), Admin (Actor), and Authorization Server (Participant). The 'Design of permissions (resources and operations)' group shows the Admin Resource server performing a self-call (1: Design coarse grained and fine grained permissions) and then sending a message (2: Express the permissions of a resource server) to the Admin. The 'Provisioning of RBAC model data' group shows the Admin sending three messages (3: Deploy permissions, 4: Deploy roles, 5: Deploy client_ID and its Client_secret) to the Authorization Server.](b5cde1e675c6bae94be8ef7f70a7a15c_img.jpg) + +``` + +sequenceDiagram + actor AR as Admin Resource server + actor Admin + participant AS as Authorization Server + + note over AR: Design of permissions (resources and operations) + AR->>AR: 1: Design coarse grained and fine grained permissions + AR->>Admin: 2: Express the permissions of a resource server + + note over Admin, AS: Provisioning of RBAC model data + Admin->>AS: 3: Deploy permissions + Admin->>AS: 4: Deploy roles + Admin->>AS: 5: Deploy client_ID and its Client_secret + +``` + +UML sequence diagram for RBAC for client credentials. The diagram shows three lifelines: Admin Resource server (Actor), Admin (Actor), and Authorization Server (Participant). The 'Design of permissions (resources and operations)' group shows the Admin Resource server performing a self-call (1: Design coarse grained and fine grained permissions) and then sending a message (2: Express the permissions of a resource server) to the Admin. The 'Provisioning of RBAC model data' group shows the Admin sending three messages (3: Deploy permissions, 4: Deploy roles, 5: Deploy client\_ID and its Client\_secret) to the Authorization Server. + +Figure 9.3.5-1 RBAC for client credentials + +#### 9.3.5.3 Impacts on Existing O-RAN Architecture Elements and Interfaces + +- The O-RAN interfaces should factor in the permissions which should be used in the context of scope in the OAuth flows. +- The keyword scope is used both in an OAuth access token as well as in the OpenAPI to define what a particular interface is allowed to do. + +#### 9.3.5.4 Solution Evaluation + +- Permissions have to be considered by all the O-RAN APIs, +- For the OpenAPIs this should be expressed as scopes, +- The semantics of the permissions which should be evaluated and validated by the resource server need to be defined. + +#### 9.3.5.5 Potential Security Recommendations + +Editor's note: The security recommendation will be left for future study. + +### 9.3.6 Solution #6: Profile for client credentials grant type clients + +#### 9.3.6.1 Background + +- To ensure interoperability we propose the need for prescriptive profiles for a client which need to carry out access control when communicating from one machine to another machine which is the resource server. + - This solution considers the below aspects for the profile, + - Resource server which exposes the APIs. + - Authorization server client (confidential client). Example of confidential client is A1 client interacting with the Near RT RIC platform. + - Security options with certificate binding [i.6]. + +#### 9.3.6.2 Solution Description + +Table 9.3.6-1 client credentials grant type client profile + +| Use Case Stage | Evolution / Specification | <>
    Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Derive an OAuth related profile for the machine-to-machine clients | | +| Actors and Roles | Resource server – provider of the APIs for the client to access
    Authorization server – an OAuth server
    Confidential client – a noninteractive client accessing an API | | +| Assumptions |
    • The solution considers the possibility of automation
    • The clients refer to machines and not human users
    • In registration of client dynamically the initial access to the OAuth server is with the initial access token
    | | +| Preconditions | P1. Design of scopes which relates to 4.7.3.2.2. in [i.1]
    P2. Administration of RBAC (solution related to RBAC)
    P3. Publish endpoint locations and authorization server capabilities [i.23], clause 2
    P4. Client X.509 certificate enrolment | | +| Begins when | Pre-conditions are met | | +| Step 1 (M) | Discover the capabilities of authorization server [i.23], clause 2 | | +| Step 2(M) | Register client dynamically [i.22], clause 3.1 | | +| Step 3(M) | Client credentials request (access token lifetime with 'expires_in' parameter) [i.5], clause 4.2.2 | | +| Step 4(M) | Return token [IETF RFC 6750] with certificate binding [i.6], clause 3 | | +| Step 5(M) | API invocation on resource server (access token with certificate binding) | | +| Ends when | API is accessed with the correct privileges | | +| Exceptions | n/a | | +| Post Conditions | n/a | | +| Traceability | n/a | | + +NOTE: The design of scopes which is mentioned in the precondition needs further study. + +``` + +@startuml +hide footbox +skinparam sequenceActorBackgroundColor White +skinparam sequenceActorBorderColor Black +skinparam sequenceParticipantBackgroundColor White +skinparam sequenceParticipantBorderColor Black +skinparam sequenceArrowColor Black +skinparam sequenceLifeLineBackgroundColor White +skinparam sequenceLifeLineBorderColor Black +skinparam shadowing false +skinparam NoteBackgroundColor White +skinparam NoteBorderColor Black + +participant "Confidential Client" as C +participant "Resource Server" as RS +participant "Authorization Server" as AS + +== Pre-condition == +note over RS +P1. Design of scopes +End note + +note over AS +P2. Administration of RBAC +P3. Publish endpoint locations + and authorization server capabilities +end note + +note over C +P4. Client X.509 certificate enrollment +End note + +== Runtime == +group Client Interaction +C -> AS: 1. Discover the capabilities of Authorization server +C -> AS: 2. Register client dynamically + +loop (for every request) +C -> AS: 3. Client credentials request(access token lifetime with 'expires_in' parameter) +AS -> C: 4. Return token with certificate binding + +group Resource Server Interaction +C -> RS: 5. API call (access token with certificate binding) +End +end +@enduml + +``` + +![Sequence diagram showing the profile for a confidential client. The diagram involves three lifelines: Confidential Client, Resource Server, and Authorization Server. It is divided into 'Pre-condition' and 'Runtime' phases. Pre-condition includes P1 (Design of scopes), P2 (Administration of RBAC), P3 (Publish endpoint locations and authorization server capabilities), and P4 (Client X.509 certificate enrollment). Runtime includes: 1. Discover the capabilities of Authorization server; 2. Register client dynamically; a loop for every request containing: 3. Client credentials request (access token lifetime with 'expires_in' parameter); 4. Return token with certificate binding; and a Resource Server Interaction containing: 5. API call (access token with certificate binding).](ac37184bafed7ae560e488fe0b61aa9a_img.jpg) + +``` + +sequenceDiagram + participant CC as Confidential Client + participant RS as Resource Server + participant AS as Authorization Server + + Note over CC, RS, AS: Pre-condition + Note over RS: P1. Design of scopes + Note over AS: P2. Administration of RBAC +P3. Publish endpoint locations +and authorization server capabilities + Note over CC: P4. Client X.509 certificate enrollment + + Note over CC, RS, AS: Runtime + CC->>AS: 1. Discover the capabilities of Authorization server + CC->>AS: 2. Register client dynamically + loop for every request + CC->>AS: 3. Client credentials request(access token lifetime with 'expires_in' parameter) + AS-->>CC: 4. Return token with certificate binding + Note over CC, RS: Resource Server Interaction + CC->>RS: 5. API call (access token with certificate binding) + end + +``` + +Sequence diagram showing the profile for a confidential client. The diagram involves three lifelines: Confidential Client, Resource Server, and Authorization Server. It is divided into 'Pre-condition' and 'Runtime' phases. Pre-condition includes P1 (Design of scopes), P2 (Administration of RBAC), P3 (Publish endpoint locations and authorization server capabilities), and P4 (Client X.509 certificate enrollment). Runtime includes: 1. Discover the capabilities of Authorization server; 2. Register client dynamically; a loop for every request containing: 3. Client credentials request (access token lifetime with 'expires\_in' parameter); 4. Return token with certificate binding; and a Resource Server Interaction containing: 5. API call (access token with certificate binding). + +Figure 9.3.6-1 Profile for confidential client + +#### 9.3.6.3 Impacts on Existing O-RAN Architecture Elements and Interfaces + +Impacts to be considered with respect to the following: + +- Resource servers + - O-RAN related APIs to define the scopes + +- Authorization server + +The OAuth servers should support the following capabilities + +- Token end points support +- Introspection end point +- Tokens with reference to access rules +- Access token lifetime +- Re-authenticate or refresh tokens +- Solution options: + - RBAC deployment +- Client (confidential client) + + +O-RAN related client credentials grant type clients ( e.g., xApps) should be capable making a client credential grant request, processing of response and forwarding the access token in an API call. +- Security options + + +O-RAN related http interfaces should support mTLS with certificate binding in [i.6]. + +#### 9.3.6.4 Solution Evaluation + +- To accomplish the access control securely for the O-RAN related machine-to-machine clients a combination of the existing RFCs have to be put together in order to maximise security and also ensure simplicity. + +#### 9.3.6.5 Potential Security Recommendations + +Editor's note: The security recommendation will be left for future study. + +# --- 10 Study and recommendation an O-RAN Authorization Server architecture + +Editor's note: This section will do a study and recommendation on an authorization server architecture to overlay on the O-RAN architecture. + +# --- 11 Conclusion + +Editor's note : This clause will provide the summary for the TR and mapping tables the key issues and solutions and it will submit the recommendations to WG1 for O-RAN authorization server. + +# Annex:Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|-------------------------------------------------------------------------------------------------------------------------| +| 2023.05.10 | 00.00.01 | Initial TS skeleton | +| 2023.08.23 | 00.00.02 | Updated the scope and reference for the TR | +| 2023.10.16 | 00.00.03 | Updated the TR based on CR approved in OAuth 2.0 meeting for Nov train | +| 2023.10.24 | 00.00.04 | Updated the TR based on CR approved during O-RAN F2F phoenix meeting | +| 2023.11.21 | 01.00 | Final version 01.00 | +| 2024.02.07 | 01.00.01 | Updated the TR based on CR approved for OAuth 2.0 TR WI meeting in Dec 2023 and Jan 2024 | +| 2024.03.05 | 01.00.02 | Updated the TR based on CR approved for OAuth 2.0 TR WI meeting in Feb 2024 | +| 2024.06.26 | 02.00.01 | Updated the TR based on CR approved for OAuth 2.0 TR WI meeting from April to June 2024 | +| 2024.07.05 | 02.00.01 | Updated the TR based on the review comments during July 2024 plenary approvals | +| 2024.10.30 | 03.00.01 | Updated the TR based CR approved before the WG11 F2F oct 2024 meeting | +| 2024.11.12 | 03.00.02 | Updated the TR based CR approved after the WG11 F2F oct 2024 meeting | +| 2024.11.26 | 03.00.03 | Updated the TR based on editorial comments during the WG11 plenary approval for Nov 2024 train | +| 2024.11.27 | 03.00.04 | Updated the TR based on editorial comments (OAuthTR meeting update) during the WG11 plenary approval for Nov 2024 train | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/03d4800d8bb684ec0a03ea93e597bba2_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/03d4800d8bb684ec0a03ea93e597bba2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3f0ec2b9507affa1dfa1273faebdef60aff59133 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/03d4800d8bb684ec0a03ea93e597bba2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c92caf0c3467172c590f20f2ca75ca58476f42ee8ada4021d722f518f39cb314 +size 22528 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/05c384f957870c7d81e5302d4ab040ab_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/05c384f957870c7d81e5302d4ab040ab_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..48ef9bfdc4c12af035467d03466bdee3c12540d4 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/05c384f957870c7d81e5302d4ab040ab_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b10499b7b8775deeb8c0f2fa4e9aa27b74653b3f2ccb6533aa3791ad670dc01d +size 35172 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/136546a13c7523efed9544a2ef1011ef_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/136546a13c7523efed9544a2ef1011ef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..77003164d20a8d3ae725e52666c2960f94b1914f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/136546a13c7523efed9544a2ef1011ef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d0856439b0d3fff1a3e42095003c44462e5075c4dcbe12675f5aced0fb8a79d +size 20458 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/19d0cb6c7e5666917cb4f7c1b78af8c4_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/19d0cb6c7e5666917cb4f7c1b78af8c4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..11baf47128bb3ff70ff0c75b231eeb03b5a9520f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/19d0cb6c7e5666917cb4f7c1b78af8c4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6fe7063cd05a907ca192a47de29004689655581d2a580e10a1abad2840968c10 +size 22394 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/551e35d264492786d0d610557ccc1b55_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/551e35d264492786d0d610557ccc1b55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eca96f14eff173ab5ead5b4ef80ff5827e92c33d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/551e35d264492786d0d610557ccc1b55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8bb0af2dd788e055159db7a05c0b9285e7d655c861421ac8dc37e4b94c3b343 +size 4454 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/6407f29eddba81826c544401f1003dcc_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/6407f29eddba81826c544401f1003dcc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..24ad192e02bf7e867981a02a15b1bec34995977f --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/6407f29eddba81826c544401f1003dcc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5cd1deaf1d1a844008274a3c7d364798d1246ff1dd1c1699cfdaa53041b5b9b7 +size 18746 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/6cd6eb961138ee2a0d44139b25c4bc44_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/6cd6eb961138ee2a0d44139b25c4bc44_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d82ee3b9a4756be27fbecfcc38b5d66a05ce0399 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/6cd6eb961138ee2a0d44139b25c4bc44_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:220b66714ae4e2a5f815e736309e1c98405106c0f48bc510fe2e0d76ae07984c +size 4660 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/72b56c480881d5956f194cd3d9d2fa2a_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/72b56c480881d5956f194cd3d9d2fa2a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6f3634ef3e6eed7fa8dbfe5aa4d65f30a16eb4ac --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/72b56c480881d5956f194cd3d9d2fa2a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:81abc8687223e31503b784e59fbb035365b432b5debc5758cd90b931e415a91f +size 45144 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/7c187af9b826881551ade314507ed45c_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/7c187af9b826881551ade314507ed45c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..166ed54f1ede790d46d0a6dcfb6a900045d90577 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/7c187af9b826881551ade314507ed45c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:28c8d7c9582c8b7f7f9c5b4a4608b6c7d5edddc2bb86a5ea641515c8a947b824 +size 24748 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/86c7af33576bc44b266982b2e684c390_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/86c7af33576bc44b266982b2e684c390_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..285f8bc777115cb600f49a0d7b01088c43e83dc1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/86c7af33576bc44b266982b2e684c390_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54f395594d2c70aad84c77e4fb1bfbc3b242fd5e72477837c80224ee2adee972 +size 55032 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/8a18c8b80acb74b8b0cfc2c8ea43093b_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/8a18c8b80acb74b8b0cfc2c8ea43093b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d2a7a2ce296a631beedb2191874c63d828a4729b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/8a18c8b80acb74b8b0cfc2c8ea43093b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8b7722f99b14bb55e2554775b6ec7fa974af062f427f5c9d19933813302e4936 +size 12999 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/96fa2d208d302896ba2c6aeeb363d4ad_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/96fa2d208d302896ba2c6aeeb363d4ad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..585b32af9824478670e150c475aee4cc3d54ea2d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/96fa2d208d302896ba2c6aeeb363d4ad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4992530830e63ab5aa9b731f3a93515213a869a92581b0b33f50b42307078a8e +size 4490 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/a422880fe923ebc3eedac9af34296bb5_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/a422880fe923ebc3eedac9af34296bb5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dac00df2ba6569b386daf448f95a05ecf8ae5f51 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/a422880fe923ebc3eedac9af34296bb5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d5169e918e0d62089f6550e71f75ab15819c185bf9671440a63ead6c7b6a86db +size 73291 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/afd41dd685f1234ef045cc1d1ec58918_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/afd41dd685f1234ef045cc1d1ec58918_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..68f5c03291e872f9ed97c3aee82f8a396e02027e --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/afd41dd685f1234ef045cc1d1ec58918_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:204a3ffa75a4decaa48533818aa9ed6d35cdf8301ee87580578080951b833d01 +size 4611 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/c14f39e909cd028b01c203f0422f2dbd_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/c14f39e909cd028b01c203f0422f2dbd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..75e4d3b9e564d3b389b91e26ae95319d477043b9 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/c14f39e909cd028b01c203f0422f2dbd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5bdc0181c91bd1cf41d46c35dbe45398b3b27769380b1e29bbd7478ecb00db8e +size 47382 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/c8c280fb70ee49fec80a2a92fb3cc3fa_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/c8c280fb70ee49fec80a2a92fb3cc3fa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..211b3e3c41561cecff2ae09d96a95a84628eec4d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/c8c280fb70ee49fec80a2a92fb3cc3fa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4bc86e5c6afb3e8822db8737a4f9651627f6881da187c576f75bbb1c6fd828a8 +size 4492 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2607b0eef27677fb38e9fdbba214fde5d86a7f72 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9e383e92647a2356488a833110e26ad296a5dd136dd01f365e78a67474a8258 +size 4548 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/ddd97486d7eb85ac62840ba93dd95844_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/ddd97486d7eb85ac62840ba93dd95844_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..80b79bc5836a15496e8adb7ad6e112697dd8a941 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/ddd97486d7eb85ac62840ba93dd95844_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4debbf5805a8c8e0dbbb0e1aca0405b042657026f4e8f6ab1b7b3a06843859d7 +size 4623 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/e290a22e05f11090af20bf5d49ecfc83_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/e290a22e05f11090af20bf5d49ecfc83_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e390bfac980dd2a15596f82f13c2e0bb563e4cc --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/e290a22e05f11090af20bf5d49ecfc83_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2a8ed2c31790566bca5921cc6c4679a16d6d23b41d18766140b012a6c5d04a3b +size 25378 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/ebc5aa6c7cde5009551538622ea13aa4_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/ebc5aa6c7cde5009551538622ea13aa4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f1ed5273557fc1eb3f6b238a4acd58895e691d9 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/ebc5aa6c7cde5009551538622ea13aa4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c565feb941215ec97986d81ae89139927991ec0ac77dc35255893da0b5b972f0 +size 40855 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/f11c22832f1b704bc78d6534ae671707_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/f11c22832f1b704bc78d6534ae671707_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..177351ab5ef5b4ac9c28fee6595310aa3c7c929b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/f11c22832f1b704bc78d6534ae671707_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:018b00f084ea7ed43fdf85c27fd850157cebe839c4f8c5fa879c60df49e9c2a5 +size 4512 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/f9bd45d4aac20c34c83d07663c69e81a_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/f9bd45d4aac20c34c83d07663c69e81a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c8d2a12a6a8f1a55d83da1424acd01c4e3cc4337 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/f9bd45d4aac20c34c83d07663c69e81a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:82635cb376092de3e43f5537d57f0c5c184d60b6418de270d4e96dcde954b921 +size 4659 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/ffef3237049b682a6291096b92367295_img.jpg b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/ffef3237049b682a6291096b92367295_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..10519cb45999886ad4e9a9caa957e76562889d8a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/ffef3237049b682a6291096b92367295_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:04e2f310846222f4c89d045b995be5b4b8c5377a2937b8db23f3ca4f8136eeb2 +size 38037 diff --git a/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/raw.md b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..6e11a810b3858774f196e4a9593c905cfa4c77e1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00/raw.md @@ -0,0 +1,4454 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****O-RAN Security Threat Modeling and Risk Assessment** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|--------------------------------------------------------------------|-----| +| List of figures ..... | 4 | +| List of tables ..... | 4 | +| Intellectual Property Rights (IPR) ..... | 5 | +| Foreword ..... | 5 | +| Modal verbs terminology ..... | 5 | +| 1 Scope ..... | 6 | +| 2 References ..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 7 | +| 3.1 Definition of terms ..... | 7 | +| 3.2 Symbols ..... | 8 | +| 3.3 Abbreviations ..... | 8 | +| 4 Overview ..... | 10 | +| 4.1 Objective and structure ..... | 10 | +| 4.2 Methodology ..... | 11 | +| 4.3 Document Scope ..... | 12 | +| 4.3.1 Scope regarding architecture ..... | 12 | +| 4.3.2 Out of scope components ..... | 13 | +| 5 Statement of compatibility with 3GPP ..... | 14 | +| 5.1 Assets and Threats ..... | 14 | +| 5.2 Security requirements ..... | 14 | +| 6 Roles-Assumptions-Assets ..... | 15 | +| 6.1 Stakeholders roles and responsibilities ..... | 15 | +| 6.2 Assumptions and prerequisites ..... | 19 | +| 6.3 Critical assets ..... | 19 | +| 7 Threat model ..... | 30 | +| 7.1 Threat surface ..... | 30 | +| 7.2 Threat agent ..... | 30 | +| 7.3 Potential vulnerabilities ..... | 30 | +| 7.4 Threats ..... | 31 | +| 7.4.0 Threat Structure ..... | 31 | +| 7.4.1 Threats against O-RAN system ..... | 32 | +| 7.4.2 Threats against O-CLOUD ..... | 61 | +| 7.4.3 Threats to open source code ..... | 80 | +| 7.4.4 Physical Threats ..... | 80 | +| 7.4.5 Threats against 5G radio networks ..... | 81 | +| 7.4.6 Threats against AI/ML system ..... | 82 | +| 7.4.7 Protocol Stack Threats ..... | 91 | +| 7.4.8 SMO Threats ..... | 92 | +| 7.4.9 Threats against Shared O-RU ..... | 99 | +| 7.5 Coverage matrix of threats ..... | 111 | +| 8 Security principles ..... | 134 | +| 8.1 Principles (SP) ..... | 134 | +| 8.1.1 SP-AUTH Mutual Authentication ..... | 134 | +| 8.1.2 SP-ACC Access Control ..... | 134 | +| 8.1.3 SP-CRYPTO Secure cryptographic, key management and PKI ..... | 134 | +| 8.1.4 SP-TCOMM Trusted Communication ..... | 134 | +| 8.1.5 SP-SS Secure storage ..... | 135 | +| 8.1.6 SP-SB Secure boot and self-configuration ..... | 135 | +| 8.1.7 SP-UPDT Secure Update ..... | 135 | +| 8.1.8 SP-RECO Recoverability & Backup ..... | 135 | + +| | | | +|--------|-------------------------------------------------------------------------------------------------------|-----| +| 8.1.9 | SP-OPNS Security management of risks in open-source components..... | 135 | +| 8.1.10 | SP-ASSU Security Assurance ..... | 136 | +| 8.1.11 | SP-PRV Privacy ..... | 136 | +| 8.1.12 | SP-SLC Continuous security development, testing, logging, monitoring and vulnerability handling ..... | 136 | +| 8.1.13 | SP-ISO Robust Isolation..... | 136 | +| 8.1.14 | SP-PHY Physical security ..... | 137 | +| 8.1.15 | SP-CLD Secure cloud computing and virtualization ..... | 137 | +| 8.1.16 | SP-ROB Robustness ..... | 137 | +| 8.1.17 | SP-IDM O-Cloud ID secure management..... | 137 | +| 8.2 | Coverage Threats - Security principles ..... | 137 | +| 9 | Risk assessment..... | 143 | +| 9.1 | Determination of severity level process ..... | 143 | +| 9.2 | Determination of likelihood level process ..... | 146 | +| 9.3 | Evaluation of the risks process..... | 147 | +| 9.4 | Risk assessment output..... | 147 | +| Annex: | Change history/Change request (history) ..... | 180 | + +# List of figures + +| | | +|--------------------------------------------------------------------------------|-----| +| Figure 4-1 : Logical Architecture of O-RAN system [i.6] | 13 | +| Figure 7-1 : Threats and Vulnerabilities for O-RAN LLS 7-2x | 36 | +| Figure 7-2 : UE Identification in Near-RT-RIC | 46 | +| Figure 7-3 : Near-RT-RIC and xApps conflict with E2 node | 51 | +| Figure 7-4 : A1 interface between the Non-RT RIC and the Near-RT RIC | 57 | +| Figure 7-5 : RAN analytics information (RAI) services via Y1 service interface | 61 | +| Figure 7-6 : Illustration of the VM/Container escape attack | 66 | +| Figure 7-7 : Illustration of the migration flooding attack | 67 | +| Figure 7-8 : Illustration of the false resource advertising attack | 67 | +| Figure 7-9 : Illustration of the migration MITM attack | 68 | +| Figure 7-10 : Illustration of the Theft-of-Service/DoS Attack | 69 | +| Figure 7-11 : Illustration of the VM/Container hyperjacking attack | 71 | +| Figure 7-12 : Illustration of a cross VM/Container side channel attack | 74 | +| Figure 7-13 : REST Protocol Stack for the A1 and R1 Interfaces | 91 | +| Figure 9-1 : Main concepts of risk assessment | 143 | + +# List of tables + +| | | +|--------------------------------------------------------------------------|-----| +| Table 5-1 : Statement of compatibility with 3GPP – Assets and Threats | 14 | +| Table 5-2 : Statement of compatibility with 3GPP – Security requirements | 14 | +| Table 6-1 : Roles and responsibilities | 15 | +| Table 6-2 : Critical assets | 21 | +| Table 7-1 : O-RAN Threat Inventory | 113 | +| Table 8-1 : Coverage Security principles-Threats (1/4) | 138 | +| Table 8-2 : Coverage Security principles-Threats (2/4) | 139 | +| Table 8-3 : Coverage Security principles-Threats (3/4) | 140 | +| Table 8-4 : Coverage Security principles-Threats (4/4) | 141 | +| Table 9-1 : Severity rating | 143 | +| Table 9-2 : Likelihood rating | 146 | +| Table 9-3 : Risk assessment matrix | 147 | +| Table 9-4 : Risk Assessment | 148 | + +# --- Intellectual Property Rights (IPR) + +This Intellectual Property Rights Policy (“IPR Policy”) will apply to documents or code developed by the O-RAN ALLIANCE for the purpose of describing key components of a Radio Access Network and their interconnections and performance, including in particular, but not limited to, the functions, behaviors, and requirements for systems, subsystems, software modules, and hardware modules, and the details of the interfaces and APIs that interconnect these components to each other or to external systems and components as well as future amendments or revisions thereto, if any. Except as otherwise defined, all capitalized terms will have the meaning defined for them in the O-RAN Constitution + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +This technical report describes the O-RAN Security Threat Modeling and Risk Assessment. It identifies assets to be protected, analyzes the O-RAN components for vulnerabilities, examines potential threats associated with those vulnerabilities, provides security principles which stakeholders should address when building a secure end-to-end O-RAN system and assesses the risks of the identified threats based on impact and likelihood factors. + +NOTE: The present document is transformed from a Technical Specification (TS) to a Technical Report (TR) as it doesn't contain normative requirements. Instead, it is an informative document that serves as a vital resource for understanding the potential risks within O-RAN and defining appropriate requirement/controls to mitigate them effectively. + +# 2 References + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18, or the latest 3GPP release prior to Release 18 that includes that document. + +**NOTE:** While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +- [i.1] 3GPP TR 21.905: Vocabulary for 3GPP Specifications +- [i.2] 3GPP TS 33.511: Security Assurance Specification (SCAS) for the next generation Node B (gNodeB) network product class +- [i.3] 3GPP TS 33.501: Security architecture and procedures for 5G system +- [i.4] 3GPP TR 33.926: Security Assurance Specification (SCAS) threats and critical assets in 3GPP network product classes +- [i.5] 3GPP TS 33.117: Catalogue of general security assurance requirements +- [i.6] ORAN ALLIANCE TS "O-RAN Architecture Description" +- [i.7] ISO 27005: Information security, cybersecurity and privacy protection — Guidance on managing information security risks +- [i.8] O-RAN ALLIANCE TS "Near-RT RIC Architecture" +- [i.9] O-RAN ALLIANCE TS "O-RAN Acceleration Abstraction Layer General Aspects and Principles" +- [i.10] O-RAN ALLIANCE: "O-RAN WG4 "Control, User and Synchronization Plane Specification" + +- [i.11] O-RAN ALLIANCE TR “Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN” +- [i.12] ERICSSON ‘Security Considerations of Open RAN’ whitepaper and slides. +- [i.13] NIST Special Publication 800-154 2 Guide to Data-Centric System Threat Modeling +- [i.14] Resource Allocation Scheme in 5G Network Slices +- [i.15] 3GPP TR 33.818: “Security Assurance Methodology (SECAM) and Security Assurance Specification (SCAS) for 3GPP virtualized network products”. +- [i.16] Fraunhofer AISEC - threat analysis of container-as-a-service for network function virtualization +- [i.17] Ecology-Based DoS Attack in Cognitive Radio Networks +- [i.18] AN ARCHITECTURAL RISK ANALYSIS OF MACHINE LEARNING SYSTEMS: Toward More Secure Machine Learning +- [i.19] 5G Americas Whitepaper October 2018 “The Evolution of Security in 5G” +- [i.20] 3GPP TR 33.845: Study on security aspects of the 5G Service Based Architecture (SBA) +- [i.21] OWASP API Security Top 10 +- [i.22] MITRE ATT&CK containers matrix +- [i.23] 3GPP TR 33.848: Study on security impacts of virtualisation +- [i.24] Graz University of Technology (2018), Meltdown and Specter +- [i.25] O-RAN ALLIANCE TS: "Near-Real-time RAN Intelligent Controller and E2 interface; E2 General Aspects and Principles" +- [i.26] NIST Special Publication 800-207, “Zero Trust Architecture,” +- [i.27] O-RAN ALLIANCE TS: "Management Plane Specification". +- [i.28] CWE-524, "Use of Cache Containing Sensitive Information", +- [i.29] CAPEC-204, “Lifting Sensitive Data Embedded in Cache”, +- [i.30] Infiltrating Corporate Intranet Like NSA, +- [i.31] Output Integrity Attack, [https://owasp.org/www-project-machine-learning-security-top-10/docs/ML09\\_2023-Output\\_Integrity\\_Attack](https://owasp.org/www-project-machine-learning-security-top-10/docs/ML09_2023-Output_Integrity_Attack) +- [i.32] ENISA: “Securing Machine Learning Algorithms”; +- [i.33] OWASP Top 10 Machine Learning Security risks, 2023 +- [i.34] O-RAN ALLIANCE TS: “O2dms Interface Specification: Kubernetes Native API Profile for Containerized NFs” +- [i.35] NIST Glossary, NIST Computer Resource Center, [Glossary | CSRC \(nist.gov\)](https://glossary.nist.gov/) + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Definition of terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [i.1], O-RAN [i.6], [i.9], [i.11] and the following apply: + +**Attack:** The realization of some specific threat that impacts the confidentiality, integrity, accountability, or availability of a resource. [adapted from i.35] + +**Attack surface:** The set of points on the boundary of a system, a system component, or an environment where an attacker can try to enter, cause an effect on, or extract data from, that system, component, or environment. [i.35] + +**O-Cloud instance ID:** The O-Cloud instance ID is a unique identifier assigned to components within the O-Cloud platform, including VMs, pods, containers, nodes, and compute pools (i.e., a cluster in Kubernetes). This ensures uniqueness across the entire O-Cloud environment, irrespective of the component type. For instance, a VM, a pod, a container, a node, and a cluster will each have a distinct O-Cloud instance ID within the platform, ensuring that there is no ambiguity in identification. + +**Radio jamming** is the deliberate jamming, blocking or creating interference with authorized wireless network. A radio jammer is a transmitter that tunes to the same frequency as the opponents' receiving equipment and with the same type of modulation, with enough power to override any signal at the receiver. + +**Radio Sniffing** technique helps to decode all sorts of essential network configuration details easily with low-cost software radios. Sniffing information can aid attackers in optimizing and crafting attacks. + +**Risk:** A measure of the extent to which an entity is threatened by a potential circumstance or event, and typically a function of: (i) the adverse impacts that would arise if the circumstance or event occurs; and (ii) the likelihood of occurrence. Information system-related security risks arise from the loss of confidentiality, integrity, or availability of information or information systems and reflect the potential adverse impacts to organizational operations (including mission, functions, image, or reputation), organizational assets, individuals, and other organizations. [i.35] + +**Risk mitigation:** Prioritizing, evaluating, and implementing the appropriate risk-reducing controls/countermeasures recommended from the risk management process. [i.35] + +**RF spoofing** refers to transmitting a fake signal meant to pretence as an actual signal. + +**Security controls:** Actions, devices, procedures, techniques, or other measures that reduce the vulnerability of an information system. [i.35] + +**Technical controls:** The security controls for an information system that are primarily implemented and executed by the information system through mechanisms contained in the hardware, software, or firmware components of the system. [i.35]. Also referred to as 'Security Controls' and 'Controls' in O-RAN. + +**Threat:** Any circumstance or event with the potential to adversely impact organizational operations (including mission, functions, image, or reputation), organizational assets, or individuals through an information system via unauthorized access, destruction, disclosure, modification of information, and/or denial of service. Also, the potential for a threat-source to successfully exploit a particular information system vulnerability. [i.35] + +**Vulnerability:** Weakness in a system, system security procedures, internal controls, or implementation that could be exploited or triggered by a threat. [i.35] + +**Y1:** An interface over which RAN analytics services are exposed by the Near-RT RIC to be consumed by Y1 consumers. + +**Y1 consumers:** A role played by entities within or outside of the PLMN trust domain that consumes the Y1 services produced by the Near-RT RIC. + +## 3.2 Symbols + +For the purposes of the present document, the symbols apply: none + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 and the following apply: + +| | | +|-------------|-------------------------------------------------------------| +| AAL | Acceleration Abstraction Layer | +| AALI | Acceleration Abstraction Layer Interface | +| AALI-C | Acceleration Abstraction Layer Interface-Common | +| AALI-C-App | Acceleration Abstraction Layer Interface-Common-Application | +| AALI-C-Mgmt | Acceleration Abstraction Layer Interface-Common-Management | +| AALI-P | Acceleration Abstraction Layer Interface-Profile | +| AI/ML | Artificial Intelligence/Machine Learning | +| DL | Down Link | + +| | | +|---------|-----------------------------------------| +| DoS | Denial of Service | +| eNB | eNodeB (applies to LTE) | +| FH | Front haul | +| FTP | File Transfer Protocol | +| FTPS | File Transfer Protocol Secure | +| GM | Grand Master | +| gNB | gNodeB (applies to NR) | +| IPSEC | Internet Protocol Security | +| KPI | Key Performance Indicator | +| KQI | Key Quality Indicator | +| L1 | Layer 1 | +| LAA | Licensed-Assisted Access | +| LBT | Listen Before Talk | +| LLS | Lower Layer Split | +| MIMO | Multiple Input, Multiple Output | +| MITM | Man In The Middle | +| MNO | Mobile Network Operator | +| NETCONF | Network Configuration Protocol | +| NF | Network Function | +| NFV | Network Function Virtualisation | +| NR-U | New Radio Unlicensed | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| PDCP | Packet Data Convergence Protocol | +| PDSCH | Physical Downlink Shared Channel | +| PUSCH | Physical Uplink Shared Channel | +| PRACH | Physical Random Access Channel | +| PRB | Physical Resource Block | +| PTP | Precision Timing Protocol | +| QoE | Quality of Experience | +| RBAC | Role-based Access Control | +| RIC | O-RAN RAN Intelligent Controller | +| RU | Radio Unit | +| SDN | Software Defined Network | +| SINR | Signal-to-Interference-plus-Noise Ratio | +| SMO | Service Management and Orchestration | +| SSH | Secure Shell | +| T-TC | Telecom Transparent Clock | +| TC | Transparent Clock | +| TLS | Transport Layer Security | +| UAV | Unmanned Aerial Vehicle | +| UL | Up Link | +| V2X | Vehicle to Everything | +| VM | Virtual machine | + +| | | +|-----|------------------------------| +| VNF | Virtualised Network Function | +| ZT | Zero Trust | +| ZTA | Zero Trust Architecture | + +# --- 4 Overview + +## 4.1 Objective and structure + +O-RAN architecture [i.6] differs significantly from the architecture of 3GPP RAN. It involves introducing new components, interfaces, and technologies, which give rise to new actors (stakeholders) and enable novel business models. Consequently, the attack surface expands considerably, and we anticipate that O-RAN design and deployment will present numerous security challenges and associated risks. These challenges primarily stem from various factors, such as the inclusion of O-RAN specific interfaces and components, the utilization of virtualization/containerization techniques, the incorporation of open-source code, and the capability to support AI/ML models, among other considerations. + +Additionally, the O-RAN architecture is being developed using zero trust (ZT) and zero trust architecture (ZTA) principles as described in the NIST Zero Trust Architecture Special Publication [i.26]. Zero trust is an evolving set of cybersecurity paradigms that move defenses from static, network-based perimeters to focus on users, assets, and resources. Zero trust assumes there is no implicit trust granted to assets or user accounts based solely on their physical or network location (i.e., local area networks versus the internet) or based on asset ownership (enterprise or personally owned). Zero trust also assumes that an adversary can always be in the network. According to the publication [i.26], zero trust is based on the following tenets that can be adapted to the O-RAN architecture. Full descriptions of each tenet can be found in [i.26]. + +- [ZT-1] All data sources and computing services are considered resources. +- [ZT-2] All communication is secured regardless of network location. +- [ZT-3] Access to individual enterprise resources is granted on a per-session basis. +- [ZT-4] Access to resources is determined by dynamic policy—including the observable state of client identity, application/service, and the requesting asset—and may include other behavioral and environmental attributes. +- [ZT-5] The enterprise monitors and measures the integrity and security posture of all owned and associated assets. No asset is inherently trusted. +- [ZT-6] All resource authentication and authorization are dynamic and strictly enforced before access is allowed. +- [ZT-7] The enterprise collects as much information as possible about the current state of assets, network infrastructure and communications and uses it to improve its security posture. + +Therefore, the security analysis and the threat model for O-RAN must be carefully studied and relevant assets/stakeholders/vulnerabilities/threats/requirements/countermeasures/recommendations must be identified to reduce risk exposure, mitigate any harmful effects, and drive to a ZTA. + +The material presented in this analysis aims at supporting various O-RAN stakeholders understanding the relevant threats resulting to an exposure of O-RAN assets by exploiting the vulnerabilities. + +The objective is to give a comprehensive and high-level view on how security is organized in O-RAN system. In this document, we assume that 3GPP security requirements are met. Unless explicitly stated, features relate to O-RAN specifications. + +This analysis is consolidated from various relevant sources, including main 5G standardization documents and telecommunication best practices (e.g., 3GPP, ETSI, NIST, ENISA). + +The first main part outlines the main stockholder roles involved in managing and using O-RAN system. Further, it addresses the prerequisites and assumptions needed to securely implement and run O-RAN systems. It also identifies the list of critical assets to be protected in integrity, availability, confidentiality, replay and authenticity. + +The second main part addresses the threat model. It identifies the threat agents, determines the threat surface, identifies vulnerabilities, and lists the threats for each O-RAN component or interface. For each threat, the description, threatened asset(s), vulnerabilities, threat agents and affected components are given. + +The third main part describes the security principles to be achieved to counter the identified threats. In addition, it illustrates the coverage between threats and security principles. + +The fourth main part is the risk assessment of the identified threats in terms of severity and likelihood. + +**NOTE 1:** The present document focuses only on the components, interfaces and protocols specified by O-RAN alliance. Components, interfaces and protocols specified by 3GPP are only referenced where needed but are not within the scope of this specific O-RAN security analysis. + +**NOTE 2:** The present document is a working document with the need to update the content on a regular basis following the risk evaluation. + +**NOTE 3:** In this document, the term NF (Network Function) is used to designate either VNF (Virtual Network Function), CNF (Cloud-native Network Function) or PNF (Physical Network Function). + +**NOTE 4:** Terms “Containers” and “Virtual Machines” are used interchangeably in this document as the implementation of O-RAN SW components could either be container-based, VM-based or hybrid (Containers and VMs together). + +## 4.2 Methodology + +The methodology adopted in this document is based on the standard ISO 27005 [i.7] which provide a detailed and flexible structure to release a risk assessment. + +The methodology followed in this document comprises three stages: + +### 1) Identification + +- a. **Identify stakeholders:** First, we need to identify the stakeholders involved in the implementation, management, operation and maintenance of the O-RAN system. Roles and responsibilities of each stakeholder are given. +- b. **Define assumptions:** The list of minimum prerequisites and assumptions need to be defined for the operational environment (not under the control of the O-RAN system) required to successfully operate the O-RAN system. +- c. **Identify assets:** First, we need to locate relevant assets the O-RAN system hold and give details about the type (Data, component, etc.), the security properties (CIA) at rest and in transit and location. +- d. **Identify threats:** We need to identify the relevant threats associated with the new O-RAN components, interfaces and technologies. In addition, the threat surface and agents are given. +- e. **Identify vulnerabilities:** O-RAN system may have weaknesses in its new O-RAN components, interfaces and technologies which need to be identified. +- f. **Define security principles:** We need to define security principles to be achieved in order to reduce risk exposure. +- g. **Elaborate and refine security principles:** Each security principle needs to be detailed and refined into requirements, recommendations and countermeasures. +- h. **Identify existing/ongoing countermeasures:** We need to identify all of O-RAN existing/ongoing controls and to take into account the protection provided by these controls before applying any new ones. + +### 2) Risk assessment + +The value for *Risk* is defined by the following equation: + +$$Risk = (the\ probability\ of\ a\ threat\ exploiting\ a\ vulnerability) \times (total\ impact\ of\ the\ vulnerability\ being\ exploited)$$ + +### 3) Risk treatment + +- a. Now that we know the level of risk that each threat poses, we need to decide how we'll treat them. There are four options: + - i. **Modify the risk** by implementing a control to reduce the likelihood of it occurring. + - ii. **Avoid the risk** by ceasing any activity that creates it. This response is appropriate if the risk is too big to manage with a security control. + - iii. **Share the risk** with a third party. There are two ways: by outsourcing the security efforts to another organization or by purchasing cyber insurance to ensure the funds to respond appropriately in the event of a disaster. + - iv. **Retain the risk.** This means that the organization accepts the risk and believes that the cost of treating it is greater than the damage that it would cause. + +## 4.3 Document Scope + +This clause comprises the architecture in the scope of the security analysis. The architecture includes the list of O-RAN components, interfaces and protocols manipulating critical assets and implementing security functions. + +### 4.3.1 Scope regarding architecture + +As specified in [i.6], the logical architecture of O-RAN includes the following components, interfaces and protocols: + +#### O-RAN components: + +- Network functions and applications + - Service Management and Orchestration (SMO) + - Non-RT RIC and rApps + - Near-RT RIC and xApps + - O-CU-CP/UP + - O-DU + - O-RU + - O-eNB +- Cloud computing platform + - O-Cloud comprising a collection of physical infrastructure nodes that meet O-RAN requirements to host the relevant O-RAN functions (such as Near-RT RIC, O-CU-CP, O-CU-UP, and O-DU), the supporting software components (such as Operating System, Virtual Machine Monitor, Container Runtime, etc.) and the appropriate management and orchestration functions. + +#### O-RAN specific interfaces: + +- A1 Interface between Non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. +- O1 Interface connecting the SMO to the Near-RT RIC, one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. +- O2 Interface between the SMO and the O-Cloud. +- E2 Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, one or more O-DUs, and one or more O-eNBs. +- Open Fronthaul CUS-Plane Interface between O-RU and O-DU. + +- Open Fronthaul M-Plane Interface between O-RU and O-DU as well as between O-RU and SMO. +- Y1 Interface over which RAN analytics services exposed by the Near-RT RIC to be consumed by Y1 consumers. + +#### Relevant Protocols used by O-RAN system for enforcing security: + +- TLS + - Should be used to protect the traffic between the O-RAN system and other network elements. It establishes a secure channel and provides CIA (Confidentiality, Integrity, Authenticity) features. + - Should be used in O1 interface for NETCONF over TLS and JSON/REST over TLS + - Should be used in A1 interface +- SSH + - Should be used in O1 interface and Fronthaul M-Plane for NETCONF over SSH +- IPSEC + - Should be used to protect E2 traffic +- FTP and FTPS + - Should be used to protect file transfers over O1 and Fronthaul M-Plane interfaces +- PTP (Precision Timing Protocol, IEEE 1588-2019) + +![Figure 4-1: Logical Architecture of O-RAN system. The diagram shows the Service Management and Orchestration Framework (SMO) at the top, containing the Non-Real Time RIC. Below it is the Near-Real Time RIC, which connects to O-eNB, O-CU-CP, and O-CU-UP. O-CU-CP connects to O-DU, which in turn connects to O-RU. O-RU connects to O-Cloud. Various interfaces are labeled: O1 (SMO to Near-RT RIC), A1 (Near-RT RIC to O-CU-CP), Y1 (Near-RT RIC to Y1 consumers), E2 (O-eNB to Near-RT RIC), E1 (O-CU-CP to O-CU-UP), F1-c (O-CU-CP to O-DU), F1-u (O-CU-UP to O-DU), and Open FH M-Plane (O-RU to O-DU). A legend indicates that green lines represent O-RAN interfaces and black lines represent 3GPP interfaces.](a422880fe923ebc3eedac9af34296bb5_img.jpg) + +Figure 4-1: Logical Architecture of O-RAN system. The diagram shows the Service Management and Orchestration Framework (SMO) at the top, containing the Non-Real Time RIC. Below it is the Near-Real Time RIC, which connects to O-eNB, O-CU-CP, and O-CU-UP. O-CU-CP connects to O-DU, which in turn connects to O-RU. O-RU connects to O-Cloud. Various interfaces are labeled: O1 (SMO to Near-RT RIC), A1 (Near-RT RIC to O-CU-CP), Y1 (Near-RT RIC to Y1 consumers), E2 (O-eNB to Near-RT RIC), E1 (O-CU-CP to O-CU-UP), F1-c (O-CU-CP to O-DU), F1-u (O-CU-UP to O-DU), and Open FH M-Plane (O-RU to O-DU). A legend indicates that green lines represent O-RAN interfaces and black lines represent 3GPP interfaces. + +Figure 4-1 : Logical Architecture of O-RAN system [i.6] + +### 4.3.2 Out of scope components + +The following components are not in the perimeter of the O-RAN system defined by the alliance; therefore, they are considered out of scope of this study: + +- 3GPP interfaces are already studied and maintained by 3GPP, +- UE, +- MEC, +- Core, + +- Antennas. + +# 5 Statement of compatibility with 3GPP + +This chapter gives the statement of compatibility with 3GPP/SCAS security Assets, Threats and Requirements. The statement of compatibility shows that 3GPP Assets/Threats/Requirements are applicable and that there is no conflict affecting the security of O-RAN components. + +## 5.1 Assets and Threats + +**Table 5-1 : Statement of compatibility with 3GPP – Assets and Threats** + +| 3GPP/SCAS document reference/clause | Description | Applicable to O-RAN | Rationale | +|-------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| TR 33.926 [i.4], clauses 5 and 6 | It describes the generic assets and threats of 3GPP network products | Yes | Since these assets/threats are for generic 3GPP (virtualized) network products, they are also applicable to O-RAN. It means that there is no need to repeat those assets/threats in this document. | +| TR 33.818 [i.15], clause 5.2.4 | It describes the generic assets, threats and requirements of 3GPP/ETSI NFV virtualized network products. | Yes | | +| TR 33.848 [i.23], clause 5 | It considers the consequences of virtualization on 3GPP architectures, in order to identify threats and subsequent security requirements relating to ETSI-defined interfaces and Security functional requirements related to Virtualization layer, hardware and resource isolation. | Yes | | + +In addition, the assets/threats related to the additional specific O-RAN interfaces and components are considered. As a result, clauses 6.3 and 7.4 elaborates the O-RAN specific assets and threats respectively. + +## 5.2 Security requirements + +**Table 5-2 : Statement of compatibility with 3GPP – Security requirements** + +| 3GPP/SCAS document reference/clause | Description | Applicable to O-RAN | Rationale | +|-----------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| TS 33.117 [i.5], clauses 4.3 and, 4.42 | It describes the general approach taken towards security functional requirements deriving from 3GPP specifications and the corresponding test cases, independent of a specific network product class. | Yes | Since these requirements are for generic 3GPP (virtualized) network products, they are to be fulfilled by O-RAN. It means that there is no need to repeat those requirements in this document. | +| TR 33.818 [i.14], clauses 5.2.5 and 5.3 | It describes the generic assets, threats and requirements of 3GPP/ETSI NFV virtualized network products. | Yes | | +| TR 33.848 [i.23], clause 5 | It considers the consequences of virtualization on 3GPP architectures, in order to identify threats and subsequent security requirements relating to ETSI-defined interfaces and | Yes | | + +| | | | | +|-----------------|------------------------------------------------------------------------------------------------------|-----|--| +| | Security functional requirements related to Virtualization layer, hardware and resource isolation. | | | +| TS 33.501 [i.3] | It describes the security architecture and procedures for 5G system including gNodeB | Yes | | +| TS 33.511 [i.2] | It describes the security requirements for the next generation Node B (gNodeB) network product class | Yes | | + +In addition, O-RAN also needs to consider the security requirements related to the additional specific O-RAN interfaces and components. As a result, clause 8 focus on the O-RAN security principles. + +# 6 Roles-Assumptions-Assets + +## 6.1 Stakeholders roles and responsibilities + +The main stakeholders managing and using the O-RAN system are the following: + +**Table 6-1 : Roles and responsibilities** + +| Role | Description | +|--------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Mobile Network Operator (MNO) | Who offers network services and has a license to operate in allocated spectrum. | +| Orchestrator | Who is in charge of operating and orchestrating the O-RAN services.
    The MNO could be the orchestrator. | +| HW/ Network vendor | Who is in charge of:
    • • Providing the network infrastructure including servers to run SDN controller, switches, routers, gateways, radio hardware, etc.
    • • Installation, maintenance or replacement of the hardware/network device
    • • Providing capability and procedures to securely configure the hardware/network device
    • • Providing capability for the hardware/network device to generate log events
    • • Providing capability for log files to be sent to an externalized log analysis system provided by the MNO
    • • Providing a process for users, including security researchers, to submit bug reports (e.g., using an issue tracker or a mailing list)
    • • Testing according to 3GPP and O-RAN test plans. Testing should include security tests of the device and its interfaces
    • • Setting up a vulnerability management process of monitoring, identifying, evaluating, treating and reporting on security vulnerabilities in the hardware/network device including firmware
    • • Maintenance of the firmware that includes providing patches for bugs and vulnerabilities
    | + +| | | +|-------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| HW/ Network administrator |

    Who is in charge of:

    • • Configuration of the hardware/network device
    • • Enabling collection of log events
    • • Collection and analysis of log events generated by the hardware/network device
    • • Deploying firmware patches in compliance with HW/ Network vendors deployment guidance
    • • Monitoring, identifying and notifying HW/ Network vendors on discovered vulnerabilities
    • • Regular testing of hardware/network configuration

    The MNO could be the HW/ Network administrator.

    | +| NF vendor |

    Who is in charge of:

    • • Developing and providing NFs (e.g. VNF, CNF, PNF) for Near-RT RIC, O-CU-CP, O-CU-UP, O-DU, etc.
    • • Providing capability and procedures to securely configure the NF
    • • Setting up a vulnerability management process of monitoring, identifying, evaluating, treating and reporting on security vulnerabilities in the NF
    • • Setting up a patch development, testing and delivery processes
    • • Maintenance of the NF that includes providing patches for bugs and vulnerabilities
    • • Providing capability for NF to generate log events
    • • Providing capability for log files to be sent to an externalized log analysis system provided by the MNO
    • • Testing according to 3GPP and O-RAN test plans. Testing should include security tests of the NF and its interface
    • • Providing a process for users, including security researchers, to submit bug reports (e.g., using an issue tracker or a mailing list)
    | +| NF administrator |

    Who is in charge of:

    • • Deploying patches in compliance with NF vendors deployment guidance
    • • Monitoring, identifying and notifying NF vendors on discovered vulnerabilities
    • • Securely configuring the NF
    • • Regular testing of the NF configuration
    • • Enabling collection of log events
    • • Analyzing log events generated by the software

    The MNO could be the NF administrator.

    | +| Virtualization/Containerization hardware infrastructure provider |

    Who is in charge of:

    • • Provides virtualized/containerized infrastructure comprising computing resources (e.g., from computing platforms), storage and network.
    • • Providing capability to securely configure the virtualization/containerization hardware infrastructure
    | + +| | | +|------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |
    • Setting up a vulnerability management process of monitoring, identifying, evaluating, treating and reporting on security vulnerabilities in the virtualization/containerization hardware infrastructure
    • Maintenance of the security of hardware infrastructure
    • Providing capability for the hardware infrastructure to generate log events
    • Providing capability for log files to be sent to an externalized log analysis system provided by the MNO
    • Providing a process for users, including security researchers, to submit bug reports (e.g., using an issue tracker or a mailing list)
    | +| Virtualization/Containerization hardware infrastructure administrator |

    Who is in charge of:

    • Deploying the Virtualization/Containerization hardware infrastructure in compliance with providers deployment guidance
    • Monitoring, identifying and notifying Virtualization/Containerization hardware infrastructure providers on discovered vulnerabilities
    • Securely configuring the Virtualization/Containerization hardware infrastructure
    • Regular testing of the Virtualization/Containerization hardware infrastructure configuration
    • Enabling collection of log events
    • Analyzing log events generated by the Virtualization/Containerization hardware infrastructure

    The MNO could be the Virtualization/Containerization hardware infrastructure administrator.

    | +| Virtualization/Containerization software infrastructure provider |

    Who is in charge of:

    • Provides virtualized/containerized infrastructure services and designs, builds, and operates virtualization/containerization infrastructure(s). The infrastructure comprises software of compute nodes such as hypervisors, host operating systems, and container run-time systems.
    • Providing capability to securely configure the virtualization/containerization software infrastructure
    • Setting up a vulnerability management process of monitoring, identifying, evaluating, treating and reporting on security vulnerabilities in the virtualization/containerization software infrastructure
    • Setting up a patch development, testing and delivery processes
    • Maintenance of the software infrastructure that includes providing patches for bugs and vulnerabilities
    • Providing capability for the software infrastructure to generate log events
    • Providing capability for log files to be sent to an externalized log analysis system provided by the MNO
    • Providing a process for users, including security researchers, to submit bug reports (e.g., using an issue tracker or a mailing list)
    | +| Virtualization/Containerization software infrastructure administrator |

    Who is in charge of:

    • Deploying patches in compliance with Virtualization/Containerization software infrastructure providers deployment guidance
    • Monitoring, identifying and notifying Virtualization/Containerization software infrastructure providers of discovered vulnerabilities
    | + +| | | +|-----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |
    • Securely configuring the Virtualization/Containerization software infrastructure
    • Regular testing of the Virtualization/Containerization software infrastructure configuration
    • Enabling collection of log events
    • Analyzing log events generated by the Virtualization/Containerization software infrastructure

    The MNO could be the Virtualization/Containerization software infrastructure administrator.

    | +| System integrator |

    Who is in charge of:

    • Appropriately integrating O-RAN HW and SW components. SW components are integrated, in most cases remotely.
    • Ensuring that those components function together as expected
    • Securely configuring (system level) the O-RAN system
    • Testing patches after deployment to ensure that they don't break other parts of O-RAN system or even expose new vulnerabilities

    The MNO could be the integrator.

    | +| System tester |

    Tester of the O-RAN system to ensure quality, security, functionality and performance.

    The MNO could be the system tester.

    | +| Other administrators |

    Identity Admin:

    • Manages (Add, Modify, Delete) administrator accounts
    • Configures general settings for administrator accounts (password policy, etc.)

    RBAC Admin

    • Generates RBAC policies and permissions on admin access

    System Admin

    • Monitors network traffic for any suspicious activity
    • Performs risk assessment and defends against zero-day malware
    • Audits the O-RAN system
    • Triggers the update of O-RAN components on the latest security patches
    • Runs regular backups
    • Regularly performs analysis of log data

    PKI Admin

    • Manage and secure private keys and certificates
    | + +**NOTE 1:** The operation, administration and orchestration of the O-RAN system can be split across multiple companies or roles. + +**NOTE 2:** A trust management mechanism becomes crucially important to realize trustworthy collaboration among the O-RAN stakeholders. + +## 6.2 Assumptions and prerequisites + +This section contains the list of minimum prerequisites and assumptions for equipment, software vendors, users and the physical environment to successfully operate the O-RAN system. + +- The operational environment of the O-RAN system provides reliable timestamps for the generation of audit records, etc. +- Administrators, integrators, operators and orchestrators are trustworthy, and trained such that they are capable of securely managing the O-RAN system and following the instructions provided by O-RAN Alliance as well as the provided guidance by vendors and service providers. +- Log files, secrets and credentials stored in external systems and related to O-RAN are protected. They are access controlled so only privileged users have access to those secrets/credentials. + +## 6.3 Critical assets + +The following table gives the list of critical assets to be protected within the O-RAN system. + +An asset in this context may encompass data, interface or component deemed valuable for the O-RAN system. A component is defined as an O-RAN network function or architectural element. + +Here's an explanation of each column, along with guidance on how to fill out the table: + +- **Asset ID:** It identifies each asset uniquely. It helps in cataloging and referencing specific assets systematically. +- **Asset Description:** A brief description of what the asset is, including its purpose, contents, and any relevant attributes. +- **Component:** It specifies the O-RAN element(s) the asset is associated with, such as O-DU, O-RU, SMO, etc. This clarifies the asset's location within the O-RAN architecture. +- **Interface:** It indicates the interface through which the asset communicates or interacts with other elements. This could be internal interfaces or external interfaces. + +NOTE: Assets can either be confined to a component (for those not shared with other O-RAN elements) or be present within a component and also transmitted to other O-RAN elements over interfaces. The way in which the 'Component' and 'Interface' columns are filled out will vary based on these situations. + +- **When:** It is a categorization of the asset's state in terms of its lifecycle or operational phase, like "at rest" or "in transit". It is used to indicate when certain protection levels should be applied. + - **When (At rest):** Marks with an 'x' if the asset needs protection while it is at rest (stored and not actively being used or transmitted). + - **When (In transit):** Marks with an 'x' if the asset needs protection during transit (being transmitted or moved). +- **Protection level (Confidentiality, Integrity, Availability, Replay, Authenticity):** These columns specify the type of protection or security measure required for the asset. An 'x' in any of these sub-columns indicates a need for measures to ensure: + - **Confidentiality:** The asset should be accessible only to authorized entities. + - **Integrity:** The asset should be protected from unauthorized changes. + - **Availability:** The asset should be accessible to authorized entities when needed. + - **Replay:** Protection against replay attacks, ensuring that repeated or delayed transmissions are identified and prevented. + - **Authenticity:** The asset should be verifiable as genuine. + +Instructions for completing the table: + +- **Asset ID:** Assign a unique identifier to each asset. +- **Asset Description:** Provide a detailed description of the asset, including its nature, purpose, and any other relevant details. + +- **Component:** Specify the component associated with the asset, if applicable. +- **Interface:** Indicate the interface(s) related to the asset. +- **When (At rest/In transit):** Mark with an 'x' if the asset requires protection either at rest or in transit. +- **Protection level:** Mark with an 'x' in the appropriate sub-columns to indicate the types of protection required for the asset. + +The categories "Data" and "Components" are defined as follows: + +- **Data:** It refers to the information that is processed, stored, and transmitted through the O-RAN architecture. +- **Components:** It involves the physical (Hardware), logical and virtual (Software) parts of the O-RAN system. + +Table 6-2 : Critical assets + +| Asset ID | Asset Description | Component | Interface | When | | Protection Level | | | | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------|---------------------|---------|------------|------------------|-----------|--------------|--------|--------------| +| | | | | At rest | In transit | Confidentiality | Integrity | Availability | Replay | Authenticity | +| Data & Interfaces | | | | | | | | | | | +| ASSET-D-01 | Critical S-Plane data such as:

    - Data flow for synchronization and timing information between nodes

    - PTP (e.g. ANNOUNCE message) transported over Fronthaul that interconnects multiple O-RUs and O-DUs.

    - Timing configuration (LLS C1, C2, C3, C4) and topology | O-DU, O-RU | Fronthaul CUS-Plane | | x | | x | | x | x | +| | | | | x | | | x | x | | | +| ASSET-D-02 | Critical Management-Plane data transported over the Fronthaul interface such as: maintenance and monitoring signals, data collected related to O-RU operations, logs (troubleshooting, trace) | O-DU, O-RU, SMO | Fronthaul M-Plane | | x | x | x | | x | x | +| | | | | x | | x | x | x | | | +| ASSET-D-03 | Critical Management-Plane data transported over the O1 interface such as:

    - Observables (events and counters) and network status provided over O1 to non-RT RIC from Near-RT RIC, O-CU and O-DU.

    - The non-RT RIC uses the O1 observables (Feedback on the fulfilment of A1 policies in the near-RT RIC) to continuously evaluate the impact of the A1 policies towards fulfilment of the RAN Intent.

    - Managed Element Telemetry to monitor the application behavior (from O-Cloud). | Near-RT RIC, Non-RT RIC, O-CU, O-DU, SMO | O1 | | x | x | x | | x | x | +| | | | | x | | x | x | x | | | +| ASSET-D-04 | Critical C-Plane data such as:

    - Scheduling information, FFT size, CP length, Subcarrier spacing, UL PRACH scheduling

    - DL and UL Beamforming commands (e.g., beam index) and scheduling

    - LBT Configuration parameters such as lbtHandle, lbtDeferFactor, lbtBackoffCounter, lbtOffset, MCOT, lbtMode, sfnSf, lbtCWconfig_H, lbtCWconfig_T, lbtTrafficClass.

    - LBT DL indication parameters such as lbtHandle, lbtResult, initialPartialSFs, bufferError, lbtCWR_Result | O-DU, O-RU | Fronthaul CUS-Plane | | x | x | x | | x | x | +| | | | | x | | | x | x | | | +| ASSET-D-05 | Critical Fronthaul U-Plane data such as: | O-DU, O-RU | | | x | | x | | x | x | + +| Asset ID | Asset Description | Component | Interface | When | | Protection Level | | | | | +|------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------|---------------------|---------|------------|------------------|-----------|--------------|--------|--------------| +| | | | | At rest | In transit | Confidentiality | Integrity | Availability | Replay | Authenticity | +| |
    • User data (i.e. DNS, PUSCH, PDSCH, etc.),
    • Control channel data (PDCCH, PUCCH, etc.),
    • I/Q samples, PRACH-related information, eCPRI, and O-RAN headers
    • MAC CEs (Control Elements)
    | | Fronthaul CUS-Plane | x | | | x | x | | | +| ASSET-D-06 | Reference signals, synchronization signal and channels in downlink and uplink between O-RU and UE | O-RU | Radio | | x | x | x | | x | x | +| ASSET-D-07 | A1 policies that are provided to the near-RT RIC over the A1 interface to guide the RAN performance towards the overall goal expressed in RAN Intent. The A1 policies are declarative policies that contain statements on policy objectives and policy resources applicable to UEs and cells. A1 policies are created, modified and deleted by the non-RT RIC. | Near-RT RIC, Non-RT RIC | A1 | | x | x | x | | | x | +| ASSET-D-08 |

    A1 Enrichment Information that is collected or derived at SMO/non-RT RIC either from non-network data sources or from network functions themselves and provided over the A1 interface to be utilized by near-RT RIC, e.g. an ML model, to improve its performance.

    Discovery and request of A1 Enrichment Information from near-RT RIC to non-RT RIC

    External Enrichment Information that is provided by an O-RAN external information source to near-RT RIC over A1

    | Near-RT RIC, Non-RT RIC | A1 | | x | x | x | | | x | +| ASSET-D-09 |

    Data transported over the E2 interface such as:

    • Near real-time information (e.g. UE basis, 2Cell basis).
    • The persistent configuration used by the near-RT RIC to control the RAN.
    • Identifiers of E2 nodes.
    • xApp-related messages.
    • Control signaling information.
    • Policies used by the Near-RT RIC to monitor, suspend/stop, override or control the behavior of E2 node.
    | O-DU, O-CU, Near-RT RIC | E2 | | x | x | x | | x | x | + +| Asset ID | Asset Description | Component | Interface | When | | Protection Level | | | | | +|------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------|---------------------------------|---------|------------|------------------|-----------|--------------|--------|--------------| +| | | | | At rest | In transit | Confidentiality | Integrity | Availability | Replay | Authenticity | +| |
    • - NEAR-RT RIC services messages (REPORT, INSERT, CONTROL and POLICY).
    • - Interface Management messages (E2 Setup, E2 Reset, E2 Node Configuration Update, Reporting of General Error Situations).
    • - Near-RT RIC Service Update messages.
    | | | | | | | | | | +| ASSET-D-10 | Database holding data from xApp applications and E2 Node | Near-RT RIC | - | x | | x | x | x | | x | +| ASSET-D-11 | E2 Node data (e.g. configuration information (cell configuration, supported slices, PLMNs, etc.), network measurements, context information, etc.) | E2 nodes | - | x | | | x | x | | | +| ASSET-D-12 |

    It consists of

    • • The Physical Infrastructure (O-Cloud Node Identifier, Pool Identifier, Pool Location Identifier, and Use Identifier) used to create the O-Cloud,
    • • The logical Clouds which it provides as interfaces for deployments, and the inventory of deployments (deployment ID and descriptor) on the cloud
    • • O-Cloud ID, IP address, IMS address, the IP address endpoint or url of the SMO and any necessary security keys or passwords for communication using O2
    • • DMS capabilities
    • • O-Cloud (IMS): List of All Resource Pools in the O-Cloud, Attributes of a specific O-Cloud, List of all resources of an O-Cloud Pool, Attributes of each O-Cloud Resource, List of all DMS
    • • O-Cloud (DMS): List of Locations Supported For a given location the Capabilities supported (e.g. Descriptor types, Technology types, Accelerator types), For a given location the Capacity of the location, For a given location the Availability of the location
    | SMO, O-CLOUD | O2, O-CLOUD internal interfaces | x | x | x | x | x | x | x | +| ASSET-D-13 |

    It includes:

    • - Telemetry information of O-Cloud deployments in the network for analyzing the O-Cloud's state and health, and for delivering on service monitoring goals. It consists of fault, performance and configuration data:
    | SMO, O-CLOUD | O2, O-CLOUD internal interfaces | x | x | x | x | x | x | x | + +| Asset ID | Asset Description | Component | Interface | When | | Protection Level | | | | | +|------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------|---------------------------------|---------|------------|------------------|-----------|--------------|--------|--------------| +| | | | | At rest | In transit | Confidentiality | Integrity | Availability | Replay | Authenticity | +| |
    • - Deployment Telemetry to monitor the number of deployment instances an O-Cloud has at that moment and how many were expected, how the on-progress deployment is going, and health checks. Additional Deployment Telemetry metrics like CPU, network, and memory usage can also be collected.
    • - Infrastructure Telemetry to monitor the health of the O-Cloud Infrastructure components. Network Operations are interested in discovering if all the components in the O-Cloud Infrastructure are working properly and at what capacity, how many deployments are running on each node, and the resource utilization of the O-Cloud Infrastructure.
    | | | | | | | | | | +| ASSET-D-14 |

    O-Cloud Provisioning information (Affinity, Anti-Affinity, Quorum Diversity Rules, capabilities, capacity and availability)

    O-Cloud software management information: catalog of authorized software and its version, list of authorized VNF/CNF, VNF/CNF description files

    | SMO, O-CLOUD | O2, O-CLOUD internal interfaces | | x | x | x | | x | x | +| ASSET-D-15 |

    Package: O-RAN Cloudified Network Function Software Image including the underlying software executable image, image properties/metadata such as descriptors, image signature(s), LCM scripts, data files, SoftwareImageId, Vendor, and version, secrets, configuration files.

    Application data: Subscriber data, Policy data, UE context, etc.

    NF location, time clock

    NF instance: Application software, guest OS, host OS, Libs, instance identity, crypto keys, namespaces, virtual resources instance states, physical hardware, etc.

    | O-CLOUD | - | x | | | x | x | | | +| ASSET-D-16 | X.509 certificates in O-RAN network such as those used for SMO, O-CU-CP, O-CU-UP, O-DU, O-RU, Near-RT RIC, Non-RT RIC, O-CLOUD, NetCONF (O1, Fronthaul) | All | O1, Fronthaul, O2, E2, A1 | x | | | x | x | | x | +| ASSET-D-17 | Security private keys in O-RAN network such as those used for SMO, O-CU-CP, O-CU-UP, O-DU, O-RU, Near-RT RIC, Non-RT RIC, O-CLOUD, NetCONF (O1, Fronthaul), for authentication, encryption, signing (e.g. for TLS and similar protocols, image signing) | All | O1, Fronthaul, O2, E2, A1 | x | | x | x | x | | x | +| ASSET-D-18 |

    O-RAN components associated and configuration data, such as:

    • - Software version information, identifier, IP address, port number, network layer parameters, time of request, previous behavior, etc.
    | All | - | x | | x | x | x | | | + +| Asset ID | Asset Description | Component | Interface | When | | Protection Level | | | | | +|------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------|-------------|------------|------------|------------------|-----------|--------------|--------|--------------| +| | | | | At rest | In transit | Confidentiality | Integrity | Availability | Replay | Authenticity | +| | - The security related parameters (such audit records, lists of algorithms which are allowed for usage, file management, hash values, etc.). | | | | | | | | | | +| ASSET-D-19 | Cryptographic keys: KgNB, KRRC-enc, KRRC-int, KUP-int, and KUP-enc (Hierarchy of cryptographic key derived from Anchor Key. (as defined in ETSI TS 133 501 clause 6.2.) | O-CU | - | x | | x | x | x | | | +| ASSET-D-20 | Credentials (Administrators): account information and passwords on SMO, O-CU-CP, O-CU-UP, O-DU, O-RU, Near-RT RIC, Non-RT RIC, O-Cloud used in O-RAN network | All | | x | | x | x | x | | | +| ASSET-D-21 | 3GPP application related data such as subscription data, session data, call control related information etc. | O-CU | | x | x | x | x | x | x | x | +| ASSET-D-22 | Inter- and intra-slice UE priority [i.14] | O-CU, O-DU | - | x | x | | x | x | | | +| ASSET-D-23 | Patches for vulnerable SW components | All | - | | x | | x | x | | x | +| ASSET-D-24 | NETCONF Configuration Access Control Model datastores | All | | x | | x | x | x | | x | +| ASSET-D-25 | Training or test data and associated labels: data sets collected externally or internally from the Near-RT RIC, O-CU and O-DU and passed to the ML training hosts in a ML system. | Near-RT RIC, Non-RT RIC, xAPPs, rAPPs | A1, O1, E2 | | x | x | x | | x | x | +| | | | | x | | x | x | x | | x | +| ASSET-D-26 | The trained ML model which includes the configured hyperparameters, inference algorithm, and learned parameters. | Near-RT RIC, Non-RT RIC, xAPPs, rAPPs | | x | | x | x | x | | | +| ASSET-D-27 | The ML prediction results built into the model (e.g. expected outcomes) | Near-RT RIC, Non-RT RIC, xAPPs, rAPPs | | | | x | x | x | | | +| ASSET-D-28 | The behavior of the ML system including tasks for data collection, data wrangling, pipeline management, model retraining, and model deployment. | Near-RT RIC, Non-RT RIC, xAPPs, rAPPs | | At runtime | | x | x | x | | | +| ASSET-D-29 | Security event log files generated by O-RAN components | All | | x | x | | x | x | | x | +| ASSET-D-30 | O-RAN specific several UE IDs | Near-RT RIC, Non-RT RIC, SMO | A1, E2, O1 | | x | x | x | | x | x | +| | | | | x | | x | x | x | | | +| ASSET-D-31 | Security telemetry from the NFV system for detecting threats and anomalies | All | O2, O-CLOUD | x | x | x | x | x | x | x | + +| Asset ID | Asset Description | Component | Interface | When | | Protection Level | | | | | +|-----------------------------------------|---------------------------------------------------------------------------------------------------------|------------------------------|---------------------------|---------|------------|------------------|-----------|--------------|--------|--------------| +| | | | | At rest | In transit | Confidentiality | Integrity | Availability | Replay | Authenticity | +| | | | internal interfaces | | | | | | | | +| ASSET-D-32 | Cryptographic keys used during secure boot, for encryption/decryption, etc. | All | - | x | | x | x | x | | | +| ASSET-D-33 | Data transported over the AALI-C-Mgmt interface | | AALI-C-Mgmt | | x | x | x | | x | x | +| ASSET-D-34 | Data transported over the AALI-C-App & AALI-P interfaces | | AALI-C-App & AALI-P | | x | | x | | x | x | +| ASSET-D-35 | Data transported over the vendor specific interface | | vendor specific interface | | x | | x | | | x | +| ASSET-D-36 | AAL profiles | AAL | | x | | | x | x | | | +| ASSET-D-37 | AAL-LPU | AAL | | x | | | x | x | | | +| ASSET-D-38 | Stored AAL data (e.g., logs, configuration data) | AAL | | x | | | x | x | | | +| ASSET-D-39 | xAppID | Near-RT RIC, xApps | | x | x | | x | | | | +| ASSET-D-40 | ML models that have not been trained yet, i.e., Initial Models and their associated learning algorithm. | Non-RT RIC, Near-RT RIC, SMO | | x | x | | x | x | | | +| Components (logical, virtual, physical) | | | | | | | | | | | +| ASSET-C-01 | Logical module: Service Management and Orchestration (SMO) | | | x | | | x | x | | x | +| ASSET-C-02 | Near-RT RIC software | | | x | | | x | x | | x | +| ASSET-C-03 | O-CU-CP software | | | x | | | x | x | | x | +| ASSET-C-04 | O-CU-UP software | | | x | | | x | x | | x | +| ASSET-C-05 | O-DU software | | | x | | | x | x | | x | +| ASSET-C-06 | O-RU software | | | x | | | x | x | | x | +| ASSET-C-07 | O-eNB | | | x | | | x | x | | x | + +| Asset ID | Asset Description | Component | Interface | When | | Protection Level | | | | | +|------------|----------------------------------------------------------------------------------------------------------------------|-----------|-----------|---------|------------|------------------|-----------|--------------|--------|--------------| +| | | | | At rest | In transit | Confidentiality | Integrity | Availability | Replay | Authenticity | +| ASSET-C-08 | O-Cloud | | | x | | | x | x | | x | +| ASSET-C-09 | xApps | | | x | | | x | x | | x | +| ASSET-C-10 | rApps | | | x | | | x | x | | x | +| ASSET-C-11 | Non-RT RIC software | | | x | | | x | x | | x | +| ASSET-C-12 | ML components deploying machine learning such as: ML training and interference hosts, ML applications (xAPPS, rAPPS) | | | x | | | x | x | | x | +| ASSET-C-12 | PNF NF equipment | | | x | | | x | x | | x | +| ASSET-C-13 | A1 termination | | | | x | x | x | x | | x | +| ASSET-C-14 | A1 interface, including protocol stack | | | | x | x | x | x | x | x | +| ASSET-C-15 | R1 termination | | | | x | x | x | x | | x | +| ASSET-C-16 | R1 interface, including protocol stack | | | | x | x | x | x | x | x | +| ASSET-C-17 | SMO Framework/Platform | x | | | | | | x | | x | +| ASSET-C-18 | SMO Functions | x | | | | | | x | | X | +| ASSET-C-19 | R1 Service Exposure Functions | x | | | | | | x | | x | +| ASSET-C-20 | A1 Functions | x | | | | | | x | | x | +| ASSET-C-21 | Data Management and Exposure Functions | x | | | | | | x | | x | +| ASSET-C-22 | O1, including protocol stack | | x | | x | x | x | x | x | x | +| ASSET-C-23 | O2, including protocol stack | | x | | x | x | x | x | x | x | +| ASSET-C-24 | OFH M-Plane, including protocol stack | | x | | x | x | x | x | x | x | +| ASSET-C-25 | OFH CUS-Plane, including protocol stack | | x | | x | x | x | x | x | x | +| ASSET-C-26 | External interfaces | | x | | x | x | x | x | x | x | +| ASSET-C-27 | External interfaces termination at SMO Framework/Platform | | x | | x | x | x | x | | x | + +| Asset ID | Asset Description | Component | Interface | When | | Protection Level | | | | | +|------------|-------------------------------------------------------------------------------|-----------------------------|-----------|---------|------------|------------------|-----------|--------------|--------|--------------| +| | | | | At rest | In transit | Confidentiality | Integrity | Availability | Replay | Authenticity | +| ASSET-C-28 | External interfaces termination at Non-RT RIC Framework | | x | | x | x | x | x | | x | +| ASSET-C-29 | AAL software including software, libraries, drivers, etc. | AAL | | x | | | x | x | | | +| ASSET-C-30 | The hardware accelerator device firmware | Hardware accelerator device | | x | | | x | x | | | +| ASSET-C-31 | Shared O-RU | x | | | | x | x | x | | x | +| ASSET-C-32 | O-RU Host | x | | | | x | x | x | | x | +| ASSET-C-33 | O-RU Tenant (Shared Resource Operator) | x | | | | x | x | x | | x | +| ASSET-C-34 | O-DU Host | x | | | | x | x | x | | x | +| ASSET-C-35 | O-DU Tenant (Shared Resource Operator) | x | | | | x | x | x | | x | +| ASSET-C-36 | O-CU Host, includes O-CU-CP and O-CU-UP software | x | | | | x | x | x | | x | +| ASSET-C-37 | O-CU Tenant (Shared Resource Operator), includes O-CU-CP and O-CU-UP software | x | | | | x | x | x | | x | +| ASSET-C-38 | SMO Host | x | | | | x | x | x | | x | +| ASSET-C-39 | SMO Tenant (Shared Resource Operator) | x | | | | x | x | x | | x | +| ASSET-C-40 | E2 interface, including protocol stack | | x | | x | x | x | x | x | x | +| ASSET-C-41 | E2 Functions | x | | | | | | x | | x | +| ASSET-C-42 | Y1 interface, including protocol stack | | x | | x | x | x | x | x | x | +| ASSET-C-43 | Y1 Functions | x | | | | | | x | | x | +| ASSET-C-44 | Service Management and Exposure (SME) | x | | | | x | x | x | | x | +| ASSET-C-45 | Data Management and Exposure (DME) | x | | | | x | x | x | | x | +| ASSET-C-46 | Topology Exposure and Inventory Management (TE&IM) | x | | | | x | x | x | | x | +| ASSET-C-47 | rApp Management | x | | | | x | x | x | | x | +| ASSET-C-48 | R1 Services | x | | | | x | x | x | | x | + +| Asset ID | Asset Description | Component | Interface | When | | Protection Level | | | | | +|------------|--------------------------------------------------------|-----------|-----------|---------|------------|------------------|-----------|--------------|--------|--------------| +| | | | | At rest | In transit | Confidentiality | Integrity | Availability | Replay | Authenticity | +| ASSET-C-49 | Network Function Orchestrator (NFO) | x | | | | x | x | x | | x | +| ASSET-C-50 | Federated O-Cloud Orchestration and Management (FOCOM) | x | | | | x | x | x | | x | +| ASSET-C-51 | RAN NF Fault Management (FM) | x | | | | x | x | x | | x | +| ASSET-C-52 | RAN NF Configuration Management (CM) | x | | | | x | x | x | | x | +| ASSET-C-53 | RAN NF Performance Management (PM) | x | | | | x | x | x | | x | +| ASSET-C-54 | A1 Enrichment Information Management | x | | | | x | x | x | | x | +| ASSET-C-55 | A1 Policy Management | x | | | | x | x | x | | x | +| ASSET-C-56 | A1 E1 Management | x | | | | x | x | x | | x | +| ASSET-C-57 | SW Package Onboarding | x | | | | x | x | x | | x | +| ASSET-C-58 | Service Orchestration | x | | | | x | x | x | | x | +| ASSET-C-59 | Service Assurance | x | | | | x | x | x | | x | +| ASSET-C-60 | RAN Analytics | x | | | | x | x | x | | x | +| ASSET-C-61 | AI/ML Workflow | x | | | | x | x | x | | X | +| ASSET-C-62 | SMOS Communication | | x | | x | x | x | x | x | x | + +# --- 7 Threat model + +## 7.1 Threat surface + +The O-RAN architecture [i.6] introduces new functions and interfaces. The introduction of additional interfaces and nodes, and the decoupling of hardware and software, expands the threat and attack surface of the network. For the purposes of this document, threat surfaces are divided into six (6) main groups: + +- Additional functions: SMO, Non-Real-Time RIC, Near-Real-Time RIC +- Additional open interfaces: A1, E2, O1, O2, Open Fronthaul +- Modified architecture: Lower Layer Split (LLS) 7-2x +- Decoupling increases threat to Trust Chain +- Containerization and Virtualization: Disaggregation of software and hardware +- Exposure to public exploits may be increased due to use of Open Source Code + +The following entry points are considered: + +- API between planes which facilitate the propagation of threats +- Threats coming from inside the O-RAN system +- Threats coming from outside the O-RAN system + +## 7.2 Threat agent + +For the purposes of this document, threat agents are categorized as follows: + +- Cyber-criminals: Represents individuals who commits cybercrimes, where he/she makes use of the computer either as a tool or as a target or as both. +- Insiders: Represents malicious attacks perpetrated on a network or computer system by a person with authorized system access. +- Hacktivists: Represents actors that perform cyber-attacks to achieve political or social gains. +- Cyber-terrorists: Represents actors that their sole aim of violence against clandestine agents and subnational groups through the compromise of O-RAN infrastructures. +- Script kiddies: Represents actors that do not poses deep technical expertise or resources to perform sophisticated attacks. +- Nation-State: actors aggressively target and gain persistent access to public and private sector networks to compromise, steal, change, or destroy information. + +## 7.3 Potential vulnerabilities + +This document addresses the following potential security vulnerabilities that are exploitable through attacks against Confidentiality, Integrity, and Availability: + +- O-RAN specific vulnerabilities + +- Unauthorized access to O-DU, O-CU-CP, O-CU-UP and RU to degrade RAN performance or execute broader network attack (Availability) +- Unprotected synchronization and control plane traffic on Open Fronthaul Interface (Integrity and Availability) +- Disable over-the-air ciphers for eavesdropping (Confidentiality) +- Near-RT RIC conflicts with O-gNB (Availability) +- x/rApps conflicts (Availability) +- x/rApps access to network and subscriber data (Confidentiality) +- Unprotected management interface (Confidentiality, Integrity, Availability) +- CP UL or DL messages can be injected for attack on UP (Availability) +- General vulnerabilities + - Decoupling of functions without hardware root of trust and software trust chain (Integrity) + - Exposure to public exploits from use of Open Source code (Confidentiality, Integrity, Availability) + - Misconfiguration, poor isolation or insufficient access management in the O-Cloud platform (Confidentiality, Integrity, Availability) + +## 7.4 Threats + +### 7.4.0 Threat Structure + +The threat analysis is carried out using a well-defined structure to present each threat case and simplify the risk analysis associated with each threat. The following table is the template used to present the threat characteristics: + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------| +| Threat ID | Unique identification per Threat (e.g. T-XX-01) | +| Threat title | Title of the threat | +| Threat description | Description of the Threat | +| Threat type | Spoofing
    Tampering
    Repudiation
    Information disclosure
    Denial of Service
    Elevation of Privilege | +| Vulnerabilities | What vulnerabilities are related to the threat? | +| Impact type | Authenticity
    Integrity
    Non-repudiation
    Confidentiality
    Availability | + +| | | +|-----------------|--------------------------------------| +| Affected Assets | Authorization | +| | Impacted Asset(s) (Data & Component) | + +For identifying threat types, we are using STRIDE, which categories threats into six distinct types: + +1. S - Spoofing identity. An application or program can masquerade as another to gain advantages not typically allowed for that program. +2. T - Tampering with data. This involves the malicious modification of data, including making unauthorized changes to a database and alteration of data as it flows between computers. +3. R - Repudiation. A user or program refuses the authenticity of a good or reasonable command or action. +4. I - Information disclosure. This involves the exposure of information to individuals with unauthorized access to it. For example, users gain the ability to read a file that they normally would not have been granted access to, or an intruder can read data in transit between computers. +5. D - Denial of service. These attacks deny service to valid users, such as making a website unavailable or unusable by flooding it with illegitimate requests to keep legitimate users without access. +6. E - Elevation of privileges. An unauthorized user gains privileged rights to access previously not granted to compromise or destroy the system, such as a change in membership. + +STRIDE maps different threat types to their corresponding impacts on system security, as shown in the following table: + +| Threat types | Impact types | +|------------------------|-------------------| +| Spoofing | Authenticity | +| Tampering | Integrity | +| Repudiation | Non-repudiability | +| Information disclosure | Confidentiality | +| Denial of Service | Availability | +| Elevation of Privilege | Authorization | + +### 7.4.1 Threats against O-RAN system + +#### 7.4.1.1 Common among O-RAN components + +The O-RAN system architecture introduces the following common threats among its components: + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RAN-01 | +| Threat title | An attacker exploits insecure designs or lack of adoption in O-RAN components | +| Threat description |

    Unauthenticated/unauthorized access to O-RAN components could possibly be achieved via the different O-RAN interfaces, depending upon the design of the hardware-software O-RAN system and how different functions are segregated within the O-RAN system.

    O-RAN components might be vulnerable if:

    • • Outdated component from the lack of update or patch management,
    • • Poorly design architecture,
    • • Missing appropriate security hardening,
    • • Unnecessary or insecure function/protocol/component.
    | + +| | | +|--|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |

    An attacker could, in such case, either inject malwares and/or manipulate existing software, harm the O-RAN components, create a performance issue by manipulation of parameters, or reconfigure the O-RAN components and disable the security features with the purpose of eavesdropping or wiretapping on various CUS & M planes, reaching northbound systems, attack broader network to cause denial-of-service, steal unprotected private keys, certificates, hash values, or other type of breaches.

    In addition, O-RAN components could be software providing network functions, so they are likely to be vulnerable to software flaws: it could be possible to bypass firewall restrictions or to take advantage of a buffer overflow to execute arbitrary commands, etc.

    | +|--|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RAN-02 | +| Threat title | An attacker exploits misconfigured or poorly configured O-RAN components | +| Threat description |

    Unauthenticated/unauthorized access to O-RAN components could possibly be achieved via the different O-RAN interfaces, depending upon the configuration of the hardware-software O-RAN system.

    O-RAN components might be vulnerable if:

    • • Errors from the lack of configuration change management,
    • • Misconfigured or poorly configured O-RAN components,
    • • Improperly configured permissions,
    • • Unnecessary features are enabled (e.g. unnecessary ports, services, accounts, or privileges),
    • • Default accounts and their passwords still enabled and unchanged,
    • • Security features are disabled or not configured securely.

    An attacker could, in such case, either inject malwares and/or manipulate existing software, harm the O-RAN components, create a performance issue by manipulation of parameters, or reconfigure the O-RAN components and disable the security features with the purpose of eavesdropping or wiretapping on various CUS & M planes, reaching northbound systems, attack broader network to cause denial-of-service, steal unprotected private keys, certificates, hash values, or other type of breaches.

    | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RAN-03 | +| Threat title | Attacks from the internet exploit weak authentication and access control to penetrate O-RAN network boundary | +| Threat description |

    Web servers serving O-RAN functional and management services should provide adequate protection.

    An attacker that have access to the uncontrolled O-RAN network could:

    • • Bypass the information flow control policy implemented by the firewall,
    • • And/or attack O-RAN components in the trusted networks by taking advantage of particularities and errors in the design and implementation of the network protocols (IP, TCP, UDP, application protocols),
    • • Use of incorrect or exceeded TCP sequence numbers,
    • • Perform brute force attacks on FTP passwords,
    • • Use of improper HTTP user sessions,
    • • Etc.

    The effects of such attacks may include:

    • • An intrusion, meaning unauthorized access to O-RAN components,
    • • Blocking, flooding or restarting an O-RAN component causing a denial of service,
    | + +| | | +|--|-----------------------------------------------------------------------------------------------------------------------------| +| |
    • Flooding of network equipment, causing a denial of service,
    • Etc.
    | +|--|-----------------------------------------------------------------------------------------------------------------------------| + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RAN-04 | +| Threat title | An attacker attempts to jam the airlink signal through IoT devices | +| Threat description | DDoS attacks on O-RAN systems: The 5G evolution means billions of things, collectively referred to as IoT, will be using the 5G O-RAN. Thus, IoT could increase the risk of O-RAN resource overload by way of DDoS attacks. Attackers create a botnet army by infecting many (millions/billions) IoT devices with a “remote-reboot” malware. Attackers instruct the malware to reboot all devices in a specific or targeted 5G coverage area at the same time. | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RAN-05 | +| Threat title | An attacker penetrates and compromises the O-RAN system through the open O-RAN’s Fronthaul, O1, O2, A1, and E2 | +| Threat description |

    O-RAN’s Fronthaul, O1, O2, A1, and E2 management interfaces are the new open interfaces that allow software programmability of RAN. These interfaces may not be secured to industry best practices.

    O-RAN components might be vulnerable if:

    • Improper or missing authentication and authorization processes,
    • Improper or missing ciphering and integrity checks of sensitive data exchanged over O-RAN interfaces,
    • Improper or missing replay protection of sensitive data exchanged over O-RAN interfaces,
    • Improper prevention of key reuse,
    • Improper implementation,
    • Improperly validate inputs, respond to error conditions in both the submitted data as well as out of sequence protocol steps.

    An attacker could, in such case, cause denial-of-service, data tampering or information disclosure, etc.

    NOTE: O-RAN interfaces allow use of TLS or SSH. Industry best practices mandate the use of TLS (v1.2 or higher) or SSH certificate-based authentication. An implementation that implements TLS version lower than 1.2 or a SSH password authentication, may become the key source of vulnerability that a malicious code will exploit to compromise the O-RAN system.

    | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RAN-06 | +| Threat title | An attacker exploits insufficient/improper mechanisms for authentication and authorization to compromise O-RAN components | +| Threat description |

    O-RAN management and orchestration should not be used without appropriate authentication and authorization and authorization checks.

    O-RAN components might be vulnerable if:

    • Unauthenticated access to O-RAN functions,
    • Improper authentication mechanisms,
    • Use of Predefined/ default accounts,
    • Weak or missing password policy,
    • Lack of mutual authentication to O-RAN components and interfaces,
    | + +| | | +|--|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |
    • • Failure to block consecutive failed login attempts,
    • • Improper authorization and access control policy.
    | +| |

    An attacker could, in such case, either inject malwares and/or manipulate existing software, harm the O-RAN components, create a performance issue by manipulation of parameters, or reconfigure the O-RAN components and disable the security features with the purpose of eavesdropping or wiretapping on various CUS & M planes, reaching northbound systems, attack broader network to cause denial-of-service, steal unprotected private keys, certificates, hash values, or other type of breaches.

    | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RAN-07 | +| Threat title | An attacker compromises O-RAN monitoring mechanisms and log files integrity and availability | +| Threat description |

    Improper / missing controls for protection of security event log files generated by O-RAN components and the lack of security events logged together with a unique system reference (e.g. host name, IP or MAC address) and the exact time the incident occurred do not allow a correct and rapid audit in case of security incident occurrence. Security restoration is delayed. Compromise of availability and integrity of security event log files could conduct to delays, wrong audit results, delays in security restoration, threats persistence.

    | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RAN-08 | +| Threat title | An attacker compromises O-RAN data integrity, confidentiality and traceability | +| Threat description |

    O-RAN components may not be secured to industry best practices. Adequate security controls are needed for protecting sensitive data stored, processed and transferred by O-RAN components.

    O-RAN components might be vulnerable if:

    • • Improper or missing ciphering of sensitive data in storage or in transfer,
    • • Improper or missing integrity mechanisms to protect sensitive data in storage or in transfer,
    • • Presence of active function(s) that reveal confidential internal data in the clear to administrators. Such functions could be, for example, local or remote OAM CLI or GUI, logging messages, alarms, configuration file exports etc.
    • • No traceability (logging) of access to personal data.

    An attacker could, in such case, cause denial-of-service, data tampering, information disclosure, spoofing identity, elevation of privilege, etc.

    | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RAN-09 | +| Threat title | An attacker compromises O-RAN components integrity and availability | +| Threat description |

    Overload situation could appear in the case of DoS attack or increased traffic. Inability to deal with such events affects availability of information or security functionalities of O-RAN components.

    O-RAN components may boot from unauthorized memory devices. Inability to deal with such events affects integrity of information or security functionalities of O-RAN components.

    Insufficient assurance of O-RAN software package integrity could affect CIA of data, services, hardware and policies during installation or upgrade phases for O-RAN components.

    An attacker could, in such case, cause denial-of-service, data tampering, information disclosure, spoofing identity, etc.

    | + +| | | +|---------------------|-------------------------------------------------------------| +| Threat ID | T-O-RAN-10 | +| Threat title | Inconsistent Log Format Impeding Effective Attack Detection | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | In the given scenario, the network operates with various devices and systems that generate logs in different formats. The lack of a standardized, common log format hinders the network operator's ability to aggregate and analyse logs centrally. This fragmentation creates blind spots and significantly delays the detection of attacks, as correlating events across disparate systems becomes challenging. An attacker can exploit this vulnerability by conducting attacks that leave traces across multiple systems, knowing that the lack of a centralized logging system will complicate the timely detection and response to the threat. | +| Threat type | Spoofing, Tampering, Repudiation, Information Disclosure, Denial of service, Elevation of privilege | +| Impact type | Authentication, Integrity, Non-repudiation, Confidentiality, Availability, Authorization | +| Affected Assets | all | + +#### 7.4.1.2 Threats against the Open Fronthaul interface and M-S-C-U planes + +The LLS architecture and the fronthaul interface introduce the following threats: + +![Diagram of O-RAN LLS (7-2x) showing threats against the Open Fronthaul interface. The diagram illustrates the architecture with Northbound n/w, O-DU, and O-RU components. It shows an 'Original connection' between O-DU and O-RU, and 'New connections' from Northbound n/w to O-DU and from O-RU to O-DU. A red icon representing an attacker is shown with arrows pointing to the O-DU and O-RU, labeled 'Attacks'. Below the diagram, text describes 'Man-in-the-Middle Attacks and unauthorized access to O-DU to degrade n/w service or execute broader n/w attack through the O-DU'.](86c7af33576bc44b266982b2e684c390_img.jpg) + +**O-RAN LLS (7-2x)** + +← Original connection → + +Northbound n/w — O-DU — O-RU + +New connection (from Northbound n/w to O-DU) + +New connection (from O-RU to O-DU) + +Attacks (indicated by red arrows from an attacker icon to O-DU and O-RU) + +Man-in-the-Middle Attacks and unauthorized access to O-DU to degrade n/w service or execute broader n/w attack through the O-DU + +Diagram of O-RAN LLS (7-2x) showing threats against the Open Fronthaul interface. The diagram illustrates the architecture with Northbound n/w, O-DU, and O-RU components. It shows an 'Original connection' between O-DU and O-RU, and 'New connections' from Northbound n/w to O-DU and from O-RU to O-DU. A red icon representing an attacker is shown with arrows pointing to the O-DU and O-RU, labeled 'Attacks'. Below the diagram, text describes 'Man-in-the-Middle Attacks and unauthorized access to O-DU to degrade n/w service or execute broader n/w attack through the O-DU'. + +**Figure 7-1 : Threats and Vulnerabilities for O-RAN LLS 7-2x** + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-FRHAUL-01 | +| Threat title | An attacker penetrates O-DU and beyond through O-RU or the Fronthaul interface to access or modify sensitive information [i.12] | +| Threat description | When having two different vendors, the O-RU and the O-DU needs to be managed as different entities and may have heterogeneous security levels. Instead, the O-DU will have to bridge the management traffic between the management system and the O-RU. Hence, the bridged traffic becomes a possible attack vector in this split architecture, allowing an attacker to potentially access or modify sensitive information. | +| Threat type | Information disclosure, Tampering | +| Vulnerabilities | Heterogeneous security levels between O-RU and O-DU provided by different vendors | +| Impact type | Confidentiality, Integrity | +| Affected Assets | Critical S-Plane data [ASSET-D-01],
    Critical Management-Plane data [ASSET-D-02],
    Critical C-Plane data [ASSET-D-04],
    Critical Fronthaul U-Plane data [ASSET-D-05] | + +| | | +|------------------|---------------------| +| Threat ID | T-FRHAUL-01A | +|------------------|---------------------| + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | An attacker penetrates O-DU and beyond through O-RU or the Fronthaul interface to impersonate a legitimate system or user [i.12] | +| Threat description | When having two different vendors, the O-RU and the O-DU need to be managed as different entities and may have heterogeneous security levels. Instead, the O-DU will have to bridge the management traffic between the management system and the O-RU. Hence, an attacker could potentially exploit the bridging mechanism to impersonate a legitimate system or user, allowing them to access the northbound systems beyond the O-DU through the Open Fronthaul interface. | +| Threat type | Spoofing | +| Vulnerabilities | Heterogeneous security levels between O-RU and O-DU provided by different vendors | +| Impact type | Authenticity | +| Affected Assets | Critical S-Plane data [ASSET-D-01],
    Critical Management-Plane data [ASSET-D-02],
    Critical C-Plane data [ASSET-D-04],
    Critical Fronthaul U-Plane data [ASSET-D-05] | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-FRHAUL-02 | +| Threat title | Unauthorized access to Open Fronthaul Ethernet L1 physical layer interface(s) to obtain protected information | +| Threat description |

    The Open Fronthaul Ethernet L1 physical interface comprises one or more coaxial cables, twisted pairs, or optical fibers. Each end of the Open Fronthaul Ethernet L1 physical interface comprises a physical connection (colloquially known as an Ethernet Port) to physical O-RAN network elements, e.g., O-DU, O-RU, etc.

    Unauthorized access to the Open Fronthaul Ethernet L1 physical layer interface (cables and connections) provides a means to launch attacks on the availability, integrity, and confidentiality of the Open Fronthaul system.

    Potential loss of confidentiality on the Open Fronthaul interface can occur from one or more of the following threats:

    • An unauthorized device on the Ethernet L1 Interface has access to U-Plane traffic on the Open Fronthaul Interface.
    • An unauthorized device on the Ethernet L1 Interface has access to S-Plane traffic on the Open Fronthaul Interface.
    • An unauthorized device on the Ethernet L1 Interface has access to C-Plane traffic on the Open Fronthaul Interface.
    • An unauthorized device on the Ethernet L1 Interface has access to M-Plane traffic on the Open Fronthaul Interface.
    | +| Threat type | Information disclosure | +| Vulnerabilities | Lack of authentication and access control to the Open Front Haul Ethernet L1 physical layer interface | +| Impact type | Confidentiality | +| Affected Assets | Critical S-Plane data [ASSET-D-01],
    Critical Management-Plane data [ASSET-D-02],
    Critical C-Plane data [ASSET-D-04],
    Critical Fronthaul U-Plane data [ASSET-D-05] | + +| | | +|---------------------|---------------------------------------------------------------------------------------------------| +| Threat ID | T-FRHAUL-03 | +| Threat title | Unauthorized access to Open Fronthaul Ethernet L1 physical layer interface(s) to disrupt services | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | The Open Fronthaul Ethernet L1 physical interface comprises one or more coaxial cables, twisted pairs, or optical fibers. Each end of the Open Fronthaul Ethernet L1 physical interface comprises a physical connection (colloquially known as an Ethernet Port) to physical O-RAN network elements, e.g., O-DU, O-RU, etc. | +| | Unauthorized access to the Open Fronthaul Ethernet L1 physical layer interface (cables and connections) provides a means to launch attacks on the availability, integrity, and confidentiality of the Open Fronthaul system. | +| | Potential loss of availability on the Open Fronthaul interface can occur from one or more of the following threats: | +| |
    • An unauthorized device on the Ethernet L1 Interface can flood the L1 interface with unintended network traffic causing disruption or degradation of authorized network elements on the Open Fronthaul interface.
    • An unauthorized device on the Ethernet L1 Interface can send Ethernet- L2 messages to authorized network devices causing disruption, denial, or degradation of the Open Fronthaul interface.
    • An attacker (person) gains access to the Open Fronthaul Ethernet L1 interface(s) and denies the Open Fronthaul services by disabling a physical connection to a network element either by removing an Ethernet port connection or cutting the physical interface (coaxial cable, twisted pair, or optical fiber).
    | +| Threat type | Denial of Service | +| Vulnerabilities | Lack of authentication and access control to the Open Front Haul Ethernet L1 physical layer interface | +| Impact type | Availability | +| Affected Assets | Critical S-Plane data [ASSET-D-01],
    Critical Management-Plane data [ASSET-D-02],
    Critical C-Plane data [ASSET-D-04],
    Critical Fronthaul U-Plane data [ASSET-D-05] | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-MPLANE-01 | +| Threat title | An attacker attempts to intercept the Fronthaul (MITM) over M Plane to obtain protected information | +| Threat description | The High bit rate Fronthaul interface imposes strict performance requirements ((bandwidth, latency, fronthaul transport link length, etc.) that limit the use of some security features, due to the increased processing delay. This opens the risk of passive wiretapping over the fronthaul interface to intercept the M plane. | +| Threat type | Information disclosure | +| Vulnerabilities | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | +| Impact type | Confidentiality | +| Affected Assets | Critical Management-Plane data [ASSET-D-02],
    Critical Management-Plane data transported over the O1 interface [ASSET-D-03] | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-MPLANE-02 | +| Threat title | An attacker attempts to intercept the Fronthaul (MITM) over M Plane to alter m-plane data | +| Threat description | The High bit rate Fronthaul interface imposes strict performance requirements ((bandwidth, latency, fronthaul transport link length, etc.) that limit the use of some security features, due to the increased processing delay. This opens the risk of Man-in-the-Middle (MITM) attacks over the fronthaul interface to intercept and modify the M plane. | +| Threat type | Tampering | + +| | | +|------------------------|-------------------------------------------------------------------------------------------------------------------------------| +| Vulnerabilities | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | +| Impact type | Integrity | +| Affected Assets | Critical Management-Plane data [ASSET-D-02],
    Critical Management-Plane data transported over the O1 interface [ASSET-D-03] | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-MPLANE-03 | +| Threat title | An attacker attempts to intercept the Fronthaul (MITM) over M Plane to disrupt services | +| Threat description | The High bit rate Fronthaul interface imposes strict performance requirements ((bandwidth, latency, fronthaul transport link length, etc.) that limit the use of some security features, due to the increased processing delay. This opens the risk of an Attacker to launch a Denial of Service (DoS) attack over the fronthaul interface to disrupt the M plane | +| Threat type | Denial of Service | +| Vulnerabilities | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | +| Impact type | Availability | +| Affected Assets | Critical Management-Plane data [ASSET-D-02],
    Critical Management-Plane data transported over the O1 interface [ASSET-D-03] | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SPLANE-01 | +| Threat title | DoS attack against a Master clock | +| Threat description |

    A denial of service (DoS) attack towards a Master clock of the timing network used by the open Fronthaul to maintain the availability and accuracy of the Master clock. An attacker can attack a master clock by sending an excessive number of time protocol packets or impersonate a legitimate clock, a slave, or an intermediate clock, by sending malicious messages to the master, thus degrading the victim's performance.

    The attacker may be residing either within the attacked network (insider) or on an external network connected to the attacked network.

    This attack results in a situation where the clock service is interrupted completely, or the timing protocol is operational, but slaves are being provided inaccurate timing information due the degraded performance of the Master clock.

    This clock service disruption or degradation in the accuracy of time may cause DoS to applications on all the RUs that rely on accurate time, potentially bringing down the cell.

    A cell outage caused by misaligned time, may further impact performance in connected neighbouring cells.

    | +| Threat type | Denial of Service | +| Vulnerabilities |
    • - Improper process to monitor and manage the performance of the Master clock
    • - ANNOUNCE messages can be sent publicly in clear text
    | +| Impact type | Availability | +| Affected Assets | Critical S-Plane data [ASSET-D-01] | + +| | | +|------------------|--------------------| +| Threat ID | T-SPLANE-02 | +|------------------|--------------------| + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Impersonation of a Master clock (Spoofing) within a PTP network with a fake ANNOUNCE message | +| Threat description |

    An attacker within the PTP network can impersonate the master clock's grandmasterIdentity value and propose himself as a grandmaster candidate by sending fake ANNOUNCE messages declaring him to be the best clock in the network. The attacker may be residing either within the attacked network (insider) or on an external network connected to the attacked network.

    This attack results in a situation where the attacker clock becomes a GM, PTP is operational, all clocks are synchronized, but the malicious GM provides intentionally inaccurate timing information.

    This degradation in the accuracy of time may cause DoS to applications on all the RUs that rely on accurate time, potentially bringing down the cell.

    A cell outage caused by misaligned time, may further impact performance in connected neighbouring cells.

    | +| Threat type | Denial of Service | +| Vulnerabilities |
    • - Inaccurate timing information
    • - Improper synchronization between clocks
    • - ANNOUNCE messages can be sent publicly in clear text
    | +| Impact type | Availability | +| Affected Assets | Critical S-Plane data [ASSET-D-01] | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SPLANE-03 | +| Threat title | A Rogue PTP Instance wanting to be a Grand Master | +| Threat description |

    An attacker can propose himself as a grandmaster candidate by sending manipulated/malicious ANNOUNCE messages declaring him to be the best clock in the network. The attacker causes other nodes in the network to believe it is a legitimate master. The attacker is internal to the attacked PTP network and could launch this attack by either modification of in-flight protocol packets or injecting fake ANNOUNCE messages to the PTP network. It is assumed that an MITM attacker has physical access to a segment of the network or has gained control of one of the nodes in the network. This attack results in a situation where the time protocol is operational, but slaves are being provided intentionally inaccurate timing information.

    This degradation in the accuracy of time may cause DoS to applications on all the RUs that rely on accurate time, potentially bringing down the cell.

    A cell outage caused by misaligned time, may further impact performance in connected neighbouring cells.

    | +| Threat type | Denial of Service | +| Vulnerabilities |
    • - Inaccurate timing information
    • - Improper synchronization between clocks
    • - ANNOUNCE messages can be sent publicly in clear text
    | +| Impact type | Availability | +| Affected Assets | Critical S-Plane data [ASSET-D-01] | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SPLANE-04 | +| Threat title | Selective interception and removal of PTP timing packets | +| Threat description | An attacker can position himself in such way that allows him to intercept and remove valid synchronization packets. This leads to clock synchronization errors of all clocks downstream or makes them go into free-running mode. | + +| | | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat type | Attacks may be launched close to the GM by tapping the egress line of an active GM clock. This impacts a larger set of slaves who depend on this GM for timing synchronization. | +| | Attacks may also target a one or more slaves. This is done by tapping the ingress line of a particular slave(s). The impact is confined to the targeted slaves. | +| | Alternatively, a MiTM attacker can reside in an intermediate node such as TCs, routers and switches to launch this attack. The attacker has physical access to a node of the PTP n/w or has gained full control of one device in the network. This requires additional capability to tap the h/w where PTP timing is implemented. | +| | Selective interception and removal can impact timing packets and cause clock degradation in attacked nodes. Removing all packets or random packets may push the clocks in attacked nodes into free running mode | +| | This attack results in a situation where the time protocol is operational, but slaves are being provided intentionally inaccurate timing information. | +| | This degradation in the accuracy of time may cause DoS to applications on all the RUs that rely on accurate time, potentially bringing down the cell. | +| Threat type | A cell outage caused by misaligned time, may further impact performance in connected neighbouring cells. | +| | Denial of Service | +| | - Inaccurate timing information | +| | - Improper synchronization between clocks | +| | - ANNOUNCE messages can be sent publicly in clear text | +| | Availability | +| Impact type | Critical S-Plane data [ASSET-D-01] | +| | | +| | | +| | | +| | | +| | | +| Affected Assets | | +| | | +| | | +| | | +| | | +| | | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SPLANE-05 | +| Threat title | Packet delay manipulation attack | +| Threat description |

    IEEE 1588 requires symmetric delays between GM and slaves. In packet delay manipulation attacks, the attacker is positioned such a way that allows him to delay the transmission of legitimate time synchronization protocol packets to the intended destination.

    An attacker launches this attack by either tapping the transmission network or by taking control of an intermediate nodes such as routers, switches and T-TCs.

    This attack results in a situation where the time protocol is operational, but slaves are being provided intentionally inaccurate timing information.

    This degradation in the accuracy of time may cause DoS to applications on all the RUs that rely on accurate time, potentially bringing down the cell.

    A cell outage caused by misaligned time, may further impact performance in connected neighbouring cells.

    | +| Threat type | Denial of Service | +| Vulnerabilities |
    • - Inaccurate timing information
    • - Improper synchronization between clocks
    • - ANNOUNCE messages can be sent publicly in clear text
    | +| Impact type | Availability | +| Affected Assets | Critical S-Plane data [ASSET-D-01] | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-CPLANE-01 | +| Threat title | Spoofing of DL C-plane messages | +| Threat description |

    The lack of authentication could allow an adversary to inject their own DL C-plane messages that falsely claim to be from the associated O-DU.

    As a result, it would block the O-RU from processing the corresponding U-Plane packets, leading to temporary DoS. (Dropping the entire DL C-plane messages achieves the same goal).

    | +| Threat type | Denial of Service | +| Vulnerabilities | Lack of authentication could allow an adversary to inject DL C-plane messages | +| Impact type | Availability | +| Affected Assets | Critical C-Plane data [ASSET-D-04] | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-CPLANE-02 | +| Threat title | Spoofing of UL C-plane messages | +| Threat description |

    The lack of authentication could allow an adversary to inject their own UL C-plane messages that falsely claim to be from the associated O-DU.

    As a result, temporarily limited cell performance (or even DoS) on cells served by the O-RU and in addition a consequential DoS threat to all O-RUs served by that O-DU will exist. (Dropping the entire UL C-plane messages achieves the same goal).

    | +| Threat type | Denial of Service | +| Vulnerabilities | Lack of authentication could allow an adversary to inject UL C-plane messages | +| Impact type | Availability | +| Affected Assets | Critical C-Plane data [ASSET-D-04] | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-UPLANE-01 | +| Threat title | An attacker attempts to intercept the Fronthaul (MITM) over U-Plane to obtain user data | +| Threat description |

    The High bit rate Fronthaul interface impose strict performance requirements ((bandwidth, latency, fronthaul transport link length, etc.) that limit the use of some security features, due to the increased processing delay. This opens the risk of Man-in-the-Middle (MITM) attacks over the fronthaul interface to intercept the U-Plane.

    For the transported U-Plane data an attacker could potentially do threats, such as passive wiretapping and intercept sensitive information.

    3GPP defines UP integrity protection algorithms in their specifications but many of the OEMs have not implemented them because of impact on the user experience (e.g. download and upload data throughputs). Enabling UP integrity protection requires considerable compute resources and adds overhead that directly impacts the maximum throughputs that can be measured on the user device. The integrity protection is enabled on the Control Plane messages but that still leaves the user's data traffic vulnerable because the Control Plane and User Plane are segregated. For example, the lack of UP integrity could enable an attacker to intercept user data.

    | +| Threat type | Information disclosure | +| Vulnerabilities | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | + +| | | +|------------------------|----------------------------------------------| +| Impact type | Confidentiality | +| Affected Assets | Critical Fronthaul U-Plane data [ASSET-D-05] | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-UPLANE-02 | +| Threat title | An attacker attempts to intercept the Fronthaul (MITM) over U-Plane to modify u-plane data | +| Threat description |

    The High bit rate Fronthaul interface impose strict performance requirements ((bandwidth, latency, fronthaul transport link length, etc.) that limit the use of some security features, due to the increased processing delay. This opens the risk of Man-in-the-Middle (MITM) attacks over the fronthaul interface to intercept the U-Plane.

    For the transported U-Plane data an attacker could potentially manipulate the data, such as modifying or altering the contents.

    3GPP defines UP integrity protection algorithms in their specifications but many of the OEMs have not implemented them because of impact on the user experience (e.g. download and upload data throughputs). Enabling UP integrity protection requires considerable compute resources and adds overhead that directly impacts the maximum throughputs that can be measured on the user device. The integrity protection is enabled on the Control Plane messages but that still leaves the user's data traffic vulnerable because the Control Plane and User Plane are segregated. For example, the lack of UP integrity could enable a rogue base station to manipulate the user data messages (i.e. DNS) and redirect a user to a malicious website.

    | +| Threat type | Tampering | +| Vulnerabilities | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | +| Impact type | Integrity | +| Affected Assets | Critical Fronthaul U-Plane data [ASSET-D-05] | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-UPLANE-03 | +| Threat title | An attacker attempts to intercept the Fronthaul (MITM) over U-Plane to disrupt services | +| Threat description |

    The High bit rate Fronthaul interface impose strict performance requirements ((bandwidth, latency, fronthaul transport link length, etc.) that limit the use of some security features, due to the increased processing delay. This opens the risk of Man-in-the-Middle (MITM) attacks over the fronthaul interface to disrupt the U-Plane.

    For the transported U-Plane data an attacker could potentially launch a Denial of Service (DoS) attack, overwhelming the fronthaul interface and impacting the performance and availability of the service.

    3GPP defines UP integrity protection algorithms in their specifications but many of the OEMs have not implemented them because of impact on the user experience (e.g. download and upload data throughputs). Enabling UP integrity protection requires considerable compute resources and adds overhead that directly impacts the maximum throughputs that can be measured on the user device. The lack of UP integrity could enable an attacker to launch a DoS attack on the fronthaul interface, causing service disruption and impacting user experience.

    | +| Threat type | Denial of Service | +| Vulnerabilities | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | +| Impact type | Availability | +| Affected Assets | Critical Fronthaul U-Plane data [ASSET-D-05] | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-UPLANE-04 | +| Threat title | Spoofing and unauthorized access of U-Plane data packets | +| Threat description | The lack of authentication and authorization mechanisms could allow an adversary to spoof a legitimate O-DU or O-RU. Once spoofed, the attacker could tamper with or inject their own U-plane data packets, falsely masquerading as those from the legitimate O-DU or O-RU. This could lead to the processing of altered or corrupted data, degrading service quality, or even causing a Denial of Service (DoS). | +| Threat type | Spoofing, Elevation of privilege | +| Vulnerabilities | Lack of authentication, and authorization protection for U-Plane data packets | +| Impact type | Authenticity, Authorization | +| Affected Asset | Critical Fronthaul U-Plane data [ASSET-D-05] | + +#### 7.4.1.3 Threats against O-RU + +##### 7.4.1.3.1 Generic threats + +The O-RU introduces the following threats: + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ORU-01 | +| Threat title | An attacker stands up a false base station attack by attacking an O-RU | +| Threat description |

    A false base station attack occurs when an attacker masquerades as a legitimate mobile network to facilitate a Man-in-The-Middle (MitM) attack between a subscriber's user equipment (UE) and the mobile network.

    There are three attack scenarios on an O-RU that enable an attacker to realize a false base station attack:

    1. 1. Hijack fronthaul to realize a false base station attack: Attacker disables an operational O-RU's access to the open fronthaul, plugs a false base station system into the operational O-RU's fronthaul interface, and launches a false base station attack with the O-RU providing the air interface.
    2. 2. Recruit a standalone O-RU to realize a false base station attack: The stand-alone O-RU is an O-RU that is not operational but is available to an attacker to incorporate into a false base station system. The attacker plugs a false base station system into the standalone O-RU's fronthaul interface and launches a false base station attack with the O-RU providing the air interface.
    3. 3. Gain unauthorized physical access to O-RU to realize a false base station attack: An attacker gains access to external and internal components of an O-RU (other than the open fronthaul interface), connects the O-RU under attack to a false base station system, and launches a false base station attack with the O-RU providing the air interface.

    Successful attacks may cause:

    1. a) For a subscriber's UE in attack scenarios 1, 2, and 3: the false base stations, also known as SUPI/5G-GUTI catchers, retrieves a subscriber identity by forcing a UE to attach to the false base station systems. This opens the door to subscriber identity interception/disclosure and unauthorized subscriber tracking attacks. These attacks include stealing subscriber information, tampering with transmitted information, tracking subscribers, and compromising subscriber privacy.
    2. b) For the operator network: in attack scenario 1, the attacker removes the operational O-RU from providing service to UEs in the coverage area served by the operational O-RU.
    3. c) For operators and vendors in attack scenarios 1, 2, and 3, the attacker recruits legitimate operator/vendor equipment for the purpose of creating a false base station attack on subscribers, possibly harming the reputation of the operator and vendor whose O-RU was used in the attack.

    NOTE: The false base station threat has existed since GSM networks and continued to evolve and persist with the evolution of mobile networks. 5G networks are expected to introduce several security enhancements over 4G

    | + +and legacy networks. Despite these security enhancements, 5G networks could still be a target of false base station attacks [i.19]. + +##### 7.4.1.3.2 Centralized user management for the O-RU related threats + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RU-02 | +| Threat title | An attacker leverages the lack of traceability with shared user accounts | +| Threat description |

    O-RU can be contacted via various controllers for example the SMO and/or the O-DU. This can lead to multiple users on these entities connecting to possibly the few shared local user accounts on the O-RU.

    O-RU components might be vulnerable if:

    • • Identical local user accounts are shared across entities (e.g: SMO, O-DU) for concurrent access
    | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RU-03 | +| Threat title | An attacker manipulates initial provisioning information | +| Threat description |

    Before the O-RU centralized user management feature is activated the initial provisioning information containing for example the IP address of the centralized authentication and authorization server needs to be configured in the O-RU. The provisioning information could be in the Software Configuration server for example and transfers the information to the O-RU

    O-RU components might be vulnerable if:

    • • Initial provisioning information from the Software configuration server could be manipulated to point to another server rather than the centralized authentication and authorization server.
    | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-RU-04 | +| Threat title | An attacker compromises O-RU user information, data integrity, confidentiality towards an external centralized authentication and authorization server | +| Threat description |

    O-RU can connect to a external centralized authentication and authorization server.

    The local users on the O-RU should be minimized and the centralized users should be maximized.

    Also credentials should be transferred between the O-RU and the centralized authentication and authorization and should be secure.

    The centralized authentication and authorization should also store the credentials of the centralized users in a secure manner

    O-RU components might be vulnerable if:

    • • O-RU credentials including account information and passwords could be mismanaged, misclassifying O-RU users between centralized and local users which could defeat the purpose of central authentication, authorization and administration
    • • Data in plain text between the O-RU and centralized Authentication and authorization server could be manipulated
    • • O-RU related credentials can be manipulated if not stored securely in the centralised server
    | + +#### 7.4.1.4 Threats against Near-RT RIC + +Near-Real-Time (RT) RIC introduces the following threats: + +![Diagram titled 'UE identification in Near-RT RIC' showing the interaction between Near-RT RIC, O-CU, O-DU, O-RU, and a UE. A malicious xApp in the Near-RT RIC is shown extracting UE to random identifier mapping. An authorized/unauthorized user is also shown interacting with the UE.](c14f39e909cd028b01c203f0422f2dbd_img.jpg) + +The diagram illustrates the UE identification process in the Near-RT RIC. It shows a stack of network components: Near-RT RIC (containing xApps), O-CU, O-DU, and O-RU. A UE is connected to the O-RU. A malicious xApp in the Near-RT RIC is shown with a red arrow pointing to it, labeled 'Can extract UE to random identifier mapping'. An 'Authorized/Unauthorized user' is shown with a red arrow pointing to the UE. A red triangle with a skull and crossbones is also shown near the UE, indicating a threat or risk. + +Diagram titled 'UE identification in Near-RT RIC' showing the interaction between Near-RT RIC, O-CU, O-DU, O-RU, and a UE. A malicious xApp in the Near-RT RIC is shown extracting UE to random identifier mapping. An authorized/unauthorized user is also shown interacting with the UE. + +Figure 7-2 : UE Identification in Near-RT-RIC + +| Threat ID | T-NEAR-RT-01 | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Malicious xApps can exploit UE identification, track UE location and change UE priority [i.12] | +| Threat description |

    xApps in the Near-RT RIC have the capability to manipulate behaviour of a certain cell, a group of UEs, and a specific UE. A malfunctioning or unavailable root of trust could potentially cause issues on the network and compromise RAN performance, privacy, etc. For example, the xApp could track a certain subscriber or impact service for a subscriber or a dedicated area. In addition, an xApp can receive order via A1 to control a certain UE and if a malfunctioning xApp receives an order to prioritize this UE, then the owner of the malfunctioning xApp knows a VIP that they want to track is in a certain area. With this command exposure, the attacker can obtain a rough location of a very important person and change the order from prioritize to deprioritize for a UE.

    Further, E2 interface exposes UE identification that can be exploited by a malicious xApp. As the E2 interface (similar to A1 interface) can point out a certain UE in the network, this will create a correlation between the randomized (anonymized) UE identities between the RAN nodes. For example, a xApp can potentially be used as a “sniffer” for UE identification. The additional challenge for the Near-RT RIC / E2 compared to the Non-RT RIC / A1 is that more frequent signalling is expected over the E2 interface to enable near-real-time operation. Therefore, the UE identifier will be exchanged more frequently over the E2 than over the A1.

    | +| Threat type | Information disclosure, Denial of Service | +| Vulnerabilities | Malicious xApps may be used to gain access to UE identification location and priority | +| Impact type | Confidentiality, Availability | +| Affected Assets | 3GPP application related data [ASSET-D-21],
    Inter- and intra-slice UE priority [ASSET-D-22],
    Near-RT RIC SW [ASSET-C-02],
    xApps [ASSET-C-09],
    E2 Functions [ASSET-C-41],
    Y1 Functions [ASSET-C-43] | + +| Threat ID | T-NEAR-RT-02 | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Risk of a malicious xApp on Near-RT RIC obtaining protected information | +| Threat description |

    The security threats associated with the onboarding and deployment of malicious xApps include:

    • Malicious xApps attaining unauthorized access to the Near-RT RIC and E2 Nodes
    • Malicious xApps abusing radio network information and control capabilities over RAN functions
    • Malicious xApp exploiting UE identification, tracking UE location and changing UE slice priority
    | + +| | | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat type | Information disclosure, Elevation of Privilege | +| Vulnerabilities | Improper or missing authentication and authorization of xApps | +| Impact type | Confidentiality, Authorization | +| Affected Assets | Database holding data from xApp applications and E2 Node [ASSET-D-10],
    E2 Node data [ASSET-D-11],
    3GPP application related data [ASSET-D-21],
    Inter- and intra-slice UE priority [ASSET-D-22] | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-NEAR-RT-02A | +| Threat title | Risk of a malicious xApp on Near-RT RIC impacting service availability | +| Threat description | The security threats associated with the onboarding and deployment of malicious xApps include:
    • Malicious xApp impacting service for a subscriber or a dedicated area
    | +| Threat type | Denial of Service | +| Vulnerabilities | Improper or missing authentication and authorization of xApps | +| Impact type | Availability | +| Affected Assets | Database holding data from xApp applications and E2 Node [ASSET-D-10],
    E2 Node data [ASSET-D-11],
    3GPP application related data [ASSET-D-21],
    Inter- and intra-slice UE priority [ASSET-D-22] | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-NEAR-RT-03 | +| Threat title | Attackers exploit non authenticated, weakly or incorrectly authenticated Near-RT RIC APIs to obtain protected information | +| Threat description |

    Not mutually authenticating xApps and Near-RT RIC platform APIs could potentially allow attackers to perform the following type of attacks [i.20]:

    • Operating malicious xApp claiming to be genuine in order to request certain services (theft of services) or information (data leakage)
    • Man in the middle attacks between a genuine xApp and a Near-RT RIC platform API
    • Querying network or UE information from a compromised xApp to Near-RT RIC platform (e.g. database via SDL API), thereby leaking potentially sensitive data about network and/or UE (potential privacy issues)
    • Subscribing a malicious xApp to services provided by the Near-RT RIC platform, such as API-related events notifications, discovery of APIs, E2SM, etc.

    The use of weak credentials in the process of API authentication can compromise the overall system. The user/password combination isn't considered safe, not only for password related attacks (e.g., brute-force), but also it would represent a high risk to allow xApps, especially 3rd party xApps, to store the user/password combo. This approach would extend the attack surface into xApps side.

    As a reference, OWASP API Security Top 10 report [i.21] indicates that authentication mechanisms are often implemented incorrectly, allowing attackers to compromise authentication tokens or to exploit implementation flaws to assume other user's identities temporarily or permanently. Compromising system's ability to identify the client/user, compromises API security overall.

    | +| Threat type | Information disclosure, Spoofing | +| Vulnerabilities | Non authenticated, weakly or incorrectly authenticated Near-RT RIC APIs | +| Impact type | Confidentiality, Authenticity | +| Affected Assets | Data transported over the E2 interface [ASSET-D-09],
    Database holding data from xApp applications and E2 Node [ASSET-D-10],
    E2 Node data [ASSET-D-11],
    Credentials (Administrators) [ASSET-D-20],
    3GPP application related data [ASSET-D-21],
    Inter- and intra-slice UE priority [ASSET-D-22], | + +| | | +|--|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Training or test data and associated labels [ASSET-D-25],
    The trained ML model [ASSET-D-26],
    Security event log files [ASSET-D-29],
    O-RAN specific several UE IDs [ASSET-D-30],
    Near-RT-RIC SW [ASSET-C-02],
    xApps [ASSET-C-09],
    E2 Functions [ASSET-C-41],
    Y1 Functions [ASSET-C-43] | +|--|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-NEAR-RT-03A | +| Threat title | Attackers exploit non authenticated, weakly or incorrectly authenticated Near-RT RIC APIs for MiTM attacks | +| Threat description |

    Not mutually authenticating xApps and Near-RT RIC platform APIs could potentially allow attackers to perform the following type of attack [i.20]:

    • - Man in the middle attacks between a genuine xApp and a Near-RT RIC platform API

    The use of weak credentials in the process of API authentication can compromise the overall system. The user/password combination isn't considered safe, not only for password related attacks (e.g., brute-force), but also it would represent a high risk to allow xApps, especially 3rd party xApps, to store the user/password combo. This approach would extend the attack surface into xApps side.

    As a reference, OWASP API Security Top 10 report [i.21] indicates that authentication mechanisms are often implemented incorrectly, allowing attackers to compromise authentication tokens or to exploit implementation flaws to assume other user's identities temporarily or permanently. Compromising system's ability to identify the client/user, compromises API security overall.

    | +| Threat type | Tampering | +| Vulnerabilities | Non authenticated, weakly or incorrectly authenticated Near-RT RIC APIs | +| Impact type | Integrity | +| Affected Assets | Data transported over the E2 interface [ASSET-D-09],
    Database holding data from xApp applications and E2 Node [ASSET-D-10],
    E2 Node data [ASSET-D-11],
    Credentials (Administrators) [ASSET-D-20],
    3GPP application related data [ASSET-D-21],
    Inter- and intra-slice UE priority [ASSET-D-22],
    Training or test data and associated labels [ASSET-D-25],
    The trained ML model [ASSET-D-26],
    Security event log files [ASSET-D-29],
    O-RAN specific several UE IDs [ASSET-D-30],
    Near-RT-RIC SW [ASSET-C-02],
    xApps [ASSET-C-09],
    E2 Functions [ASSET-C-41],
    Y1 Functions [ASSET-C-43] | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-NEAR-RT-04 | +| Threat title | Attackers exploit non authorized Near-RT RIC APIs to access resources and services which they are not entitled to use, to obtain protected information. | +| Threat description |

    If the API consumers are not authorized by the API producers, attackers (e.g, malicious xApps) would potentially be able to perform the following types of attacks:

    • - Abuse and/or theft of services or information (data leakage), requesting and successfully obtaining them from the platform, e.g, in order to extract potentially sensitive information from the network and/or UEs

    As a reference, OWASP API Security Top 10 report [i.21] indicates that 'Broken Object Level Authorization' has been the most common and impactful attack on APIs. Even if the application implements a proper infrastructure for authorization checks, developers might forget to use these checks before accessing a sensitive

    | + +| | | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |

    object. Unauthorized access can result in data disclosure to unauthorized parties, data loss, or data manipulation.

    In the actual context of Near-RT RIC [i.8], the platform as API producer is responsible to specify those rights/privileges for the platform services as resources to the xApps as consumers. In general, an xApp should only have the required set of permissions to perform the actions for which they are authorized, and no more.

    NOTE: The investigation of services for which the API producer is the xApp is for further study

    | +| Threat type | Information disclosure, Elevation of Privilege | +| Vulnerabilities | Non-authorized RT RIC APIs | +| Impact type | Confidentiality, Authorization | +| Affected Assets | Data transported over the E2 interface [ASSET-D-09],
    Database holding data from xApp applications and E2 Node [ASSET-D-10],
    E2 Node data [ASSET-D-11],
    Credentials (Administrators) [ASSET-D-20],
    3GPP application related data [ASSET-D-21],
    Inter- and intra-slice UE priority [ASSET-D-22],
    Training or test data and associated labels [ASSET-D-25],
    The trained ML model [ASSET-D-26],
    Security event log files [ASSET-D-29],
    O-RAN specific several UE IDs [ASSET-D-30],
    Near-RT-RIC SW [ASSET-C-02],
    xApps [ASSET-C-09],
    E2 Functions [ASSET-C-41],
    Y1 Functions [ASSET-C-43] | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-NEAR-RT-04A | +| Threat title | Attackers exploit non authorized Near-RT RIC APIs to access resources and services which they are not entitled to use, to disrupt services. | +| Threat description |

    If the API consumers are not authorized by the API producers, attackers (e.g, malicious xApps) would potentially be able to perform the following types of attacks:

    • - Negatively impacting the network performance due to malicious policies over E2 Nodes
    • - Flooding the platform with resource demanding operations that may lead to a Denial of Service attack

    As a reference, OWASP API Security Top 10 report [i.21] indicates that ‘Broken Object Level Authorization’ has been the most common and impactful attack on APIs. Even if the application implements a proper infrastructure for authorization checks, developers might forget to use these checks before accessing a sensitive object. Unauthorized access can result in data disclosure to unauthorized parties, data loss, or data manipulation.

    In the actual context of Near-RT RIC [i.8], the platform as API producer is responsible to specify those rights/privileges for the platform services as resources to the xApps as consumers. In general, an xApp should only have the required set of permissions to perform the actions for which they are authorized, and no more.

    NOTE: The investigation of services for which the API producer is the xApp is for further study

    | +| Threat type | Denial of Service | +| Vulnerabilities | Non-authorized RT RIC APIs | +| Impact type | Availability | +| Affected Assets | Data transported over the E2 interface [ASSET-D-09],
    Database holding data from xApp applications and E2 Node [ASSET-D-10],
    E2 Node data [ASSET-D-11],
    Credentials (Administrators) [ASSET-D-20],
    3GPP application related data [ASSET-D-21],
    Inter- and intra-slice UE priority [ASSET-D-22],
    Training or test data and associated labels [ASSET-D-25], | + +| | | +|--|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | The trained ML model [ASSET-D-26],
    Security event log files [ASSET-D-29],
    O-RAN specific several UE IDs [ASSET-D-30],
    Near-RT-RIC SW [ASSET-C-02],
    xApps [ASSET-C-09],
    E2 Functions [ASSET-C-41],
    Y1 Functions [ASSET-C-43] | +|--|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-NEAR-RT-05 | +| Threat title | Attackers exploit non uniquely identified xApps using a trusted xAppID to access resources and services which they are not entitled to use. | +| Threat description |

    Not uniquely identifying xApps using a trusted xAppID potentially entails certain threats and potential attacks:

    • - A non-unique xAppID might cause misidentification of an xApp, possibly allowing a potentially malicious xApp to request certain services (theft of services), information (data leakage), or alter existing information
    • - A malicious xApp might use the xAppID assigned to a legitimate xApp to request services or information from Near-RT RIC platform
    • - A non-unique xApp ID could make it impossible to accurately assign actions to the correct xApp
    • - A non-unique xApp ID could make it difficult to recognize that a malicious xApp is in the environment
    | +| Threat type | Information disclosure, Elevation of Privilege | +| Vulnerabilities | Not uniquely identifying xApps using a trusted xAppID | +| Impact type | Confidentiality, Authorization | +| Affected Assets | xAppID [ASSET-D-39],
    Near-RT-RIC SW [ASSET-C-02],
    xApps [ASSET-C-09] | + +#### 7.4.1.5 Threats against Non-RT RIC + +Threats against Non-RT RIC include: + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-NONRTRIC-01 | +| Threat title | An attacker penetrates the Non-RT RIC to cause a denial of service or degrade the performance | +| Threat description |

    An attacker penetrates the Non-RT RIC through the SMO and attempts to trigger a Denial of Service or degrade the performance of non-RT RIC so that non-RT RIC would not be liable for ensuring:

    • • The monitoring or tracing of the network to understand the effect of the A1 policy on performance in Near-RT RIC
    • • The update of A1 policy
    • • The exposure and secure delivery of A1 Enrichment Information to near-RT RIC
    • • The setup of access control rules and the selection of which Enrichment Information ID (EiId) are exposed to a near-RT RIC
    | + +| | | +|---------------------------|-----------------------------------------------------------------------------| +| Threat ID | T-NONRTRIC-02 | +| Threat title | UE tracking in the Non-RT RIC | +| Threat description | An attacker gains access to the Non-RT RIC through the SMO for UE tracking. | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------| +| Threat ID | T- NONRTRIC-03 | +| Threat title | Data Corruption/Modification | +| Threat description | An attacker gains access to the Non-RT RIC through the SMO to cause Data Corruption/Modification. | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-NONRTRIC-04 | +| Threat title | Attacker exploits non-uniquely identified rApp instances | +| Threat description |

    An attacker can exploit non-uniquely identified rApp instances using a trusted rAppID to gain unauthorized access to services and data. Potential threats and attacks include:

    • - A non-unique rAppID might cause misidentification of an rApp instance, possibly allowing a potentially malicious rApp instance to request certain services (theft of services), information (data leakage), or alter existing information
    • - A malicious rApp instance might use the rAppID assigned to a legitimate rApp instance to request access to R1 services or data
    • - A non-unique rApp ID could make it impossible to accurately assign actions to the correct rApp instance
    • - A non-unique rApp ID could make it difficult to recognize that a malicious rApp instance is in the environment
    | + +#### 7.4.1.6 Threats against xApps + +xApps introduce the following threats: + +![Diagram showing a Near-RT RIC box containing a 'vulnerable xApp' box. An arrow labeled 'E2 interface' points from the 'vulnerable xApp' box to an 'Error' box (containing a blue circle with a white 'X'). Below the 'Error' box is the text 'Denial of service / degraded service quality'. An arrow points from the 'Error' box to an 'E2 node' box.](136546a13c7523efed9544a2ef1011ef_img.jpg) + +Diagram showing a Near-RT RIC box containing a 'vulnerable xApp' box. An arrow labeled 'E2 interface' points from the 'vulnerable xApp' box to an 'Error' box (containing a blue circle with a white 'X'). Below the 'Error' box is the text 'Denial of service / degraded service quality'. An arrow points from the 'Error' box to an 'E2 node' box. + +xApps can attack availability + +**Figure 7-3 : Near-RT-RIC and xApps conflict with E2 node** + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-xApp-01 | +| Threat title | An attacker exploits xApps vulnerabilities and misconfiguration to alter data transmitted over A1 or E2 interfaces. | +| Threat description |

    Vulnerabilities can potentially exist in any xApp if it stems from an untrusted or unmaintained source. If attackers can find an exploitable xApp, they can alter data transmitted over A1 or E2 interfaces, potentially disrupting the normal functioning of the Near-RT RIC.

    The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 or E2 interfaces, extract sensitive information, etc.

    Malicious xApps can manipulate the behaviour of the Near-RT RIC, allowing attackers to alter data and impact the performance of the network service.

    | + +| | | +|------------------------|-----------------------------------------------------------------------------------------------------------------| +| Threat type | Tampering | +| Vulnerabilities | xApp stems from an untrusted or unmaintained source | +| Impact type | Authenticity | +| Affected Assets | O-CU-CP software [ASSET-C-03], O-eNB [ASSET-C-07], O-Cloud [ASSET-C-08], xApps [ASSET-C-09], rApps [ASSET-C-10] | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-xApp-01A | +| Threat title | An attacker exploits xApps vulnerabilities and misconfiguration to extract sensitive information. | +| Threat description |

    Vulnerabilities can potentially exist in any xApp if it stems from an untrusted or unmaintained source. If attackers can find exploitable xApp, they can extract sensitive information, potentially gaining access to confidential data.

    The actual consequences may vary. For example, an attacker may extract sensitive information about network configuration, user data, or other confidential information.

    Malicious xApps can be used to extract sensitive information, allowing attackers to gain unauthorized access to sensitive data and potentially compromise the security of the Near-RT RIC.

    | +| Threat type | Information Disclosure | +| Vulnerabilities | xApp stems from an untrusted or unmaintained source | +| Impact type | Confidentiality | +| Affected Assets | O-CU-CP software [ASSET-C-03], O-DU software [ASSET-C-05], O-eNB [ASSET-C-07], O-Cloud [ASSET-C-08], xApps [ASSET-C-09], rApps [ASSET-C-10] | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-xApp-01B | +| Threat title | An attacker exploits xApps vulnerabilities and misconfiguration to disrupt Near-RT RIC functions | +| Threat description |

    Vulnerabilities can potentially exist in any xApp if it stems from an untrusted or unmaintained source. If attackers can find exploitable xApp, they can disrupt the normal functioning of the Near-RT RIC, potentially causing a denial of service.

    The actual consequences may vary. For example, an attacker may cause performance degradation, service interruptions, or complete unavailability of the Near-RT RIC.

    Malicious xApps can be used to impact Near-RT RIC functions, allowing attackers to disrupt the normal functioning of the network service and potentially cause a denial of service.

    | +| Threat type | Denial of Service | +| Vulnerabilities | xApp stems from an untrusted or unmaintained source | +| Impact type | Availability | +| Affected Assets | O-CU-CP software [ASSET-C-03], O-DU software [ASSET-C-05], O-eNB [ASSET-C-07], O-Cloud [ASSET-C-08], xApps [ASSET-C-09], rApps [ASSET-C-10] | + +| | | +|---------------------|---------------------------------------------------------------------------------------------------------------| +| Threat ID | T-xApp-01C | +| Threat title | An attacker exploits xApps vulnerabilities and misconfiguration to gain unauthorized control over Near-RT RIC | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description |

    Vulnerabilities can potentially exist in any xApp if it stems from an untrusted or unmaintained source. If attackers can find exploitable xApp, they can gain unauthorized control over another xApp or the whole Near-RT RIC, potentially allowing them to perform actions that would normally be restricted.

    The actual consequences may vary. For example, an attacker may gain the ability to manipulate the behaviour of a certain cell, a group of UEs, or a specific UE, or even take control of the entire Near-RT RIC.

    Malicious xApps can be used to elevate the attacker's privileges, allowing them to perform unauthorized actions and gain control over the Near-RT RIC, potentially leading to a complete compromise of the system.

    | +| Threat type | Elevation of Privilege | +| Vulnerabilities | xApp stems from an untrusted or unmaintained source | +| Impact type | Authorization | +| Affected Assets | O-CU-CP software [ASSET-C-03], O-DU software [ASSET-C-05], O-eNB [ASSET-C-07], O-Cloud [ASSET-C-08], xApps [ASSET-C-09], rApps [ASSET-C-10] | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-xApp-02 | +| Threat title | Conflicting xApps impact O-RAN system functions to degrade performance or create a DoS [i.12] | +| Threat description |

    Conflicting xApps impact O-RAN system functions such as mobility management, admission controls, bandwidth management and load balancing for the purpose of performance degradation.

    There is no clear functional split between the Near-RT RIC and the O-gNB. The functional split depends on the available xApps and the capabilities exposed by the O-gNB. This creates possible conflicts between the decisions taken by the Near-RT RIC and the O-gNB that could lead to instability in the network, which introduces vulnerabilities that could be exploited by threat actors. For example, a threat actor can utilize a malicious xApp that intentionally triggers RRM decisions conflicting with the O-gNB internal decisions to create denial of service.

    | +| Threat type | Denial of Service | +| Vulnerabilities |

    xApps may be misconfigured or compromised

    Failing or misconfigured authentication and authorization in xApp

    | +| Impact type | Availability | +| Affected Assets | O-CU-CP software [ASSET-C-03], O-DU software [ASSET-C-05], O-eNB [ASSET-C-07], O-Cloud [ASSET-C-08], xApps [ASSET-C-09], rApps [ASSET-C-10] | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-xApp-03 | +| Threat title | An attacker compromises xApp isolation | +| Threat description |

    An attacker can exploit weaknesses and vulnerabilities to compromise xApp isolation and to break out of xApp confinement. For example, attacker can use the underlying system vulnerabilities to easily breach isolation and confinement.

    Adversary can use side effects resulting from a shared resource usage to deduce information from co-hosted xApps.

    Gaining unauthorized access to the underlying system provides new opportunities to exploit vulnerabilities in other xApps or O-RAN components to intercept and spoof network traffic, to degrade services (DoS), etc.

    | + +| | | +|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-xApp-04 | +| Threat title | False or malicious A1 policies from the Non-RT RIC inform behavior of xApps to trigger a DoS, affect performance, or locate a subscriber. | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | Unauthorized access to the Non-RT RIC enables the creation of ‘false policies’ that can be issued to the Near-RT RIC for enforcement. Existing Near-RT RIC policies could also be modified to achieve a false policy. False policies passed to the Near-RT RIC would be persistent until they were modified or deleted by the Non-RT RIC or the Near-RT RIC power cycles. | +| | False policies can be created to have numerous impacts to the normal performance of the RAN. A single false A1 policy can target a specific UE, groups of UEs, or an entire cell. A false policy could influence the Near-RT RIC to configure the O-DU and O-RU functions to support Denial of Service (DoS) attacks by using feedback data to degrade RAN performance. | +| | False policies could also be used for the purpose of locating a subscriber or group of subscribers. In this case, the false policy would cause the Near-RT RIC to isolate a subscriber in the O-CU. The Near-RT RIC could also use MIMO beamforming in the O-DU and O-RU to isolate a user onto a single beam. The data feedback from the RAN can include UE location or trajectory information from GPS data. The subscriber location would be attained from access to the Non-RT RIC in the SMO function. | +| | The Near-RT RIC is capable of steering traffic to achieve optimal QoS or QoE performance. A false policy could notionally cause the Near-RT RIC to steer user data to isolate the data in order to facilitate a cyber-attack. | + +#### 7.4.1.7 Threats against rApps + +Threats against rApps include: + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-01 | +| Threat title | Conflicting rApps unintentionally or maliciously impact O-RAN system functions to degrade performance or trigger a DoS | +| Threat description |

    rApps in the Non-RT RIC can be provided by different vendors. For example, one vendor can provide the rApp for Carrier license scheduling and another vendor provide the rApp for energy saving, etc.

    This creates the risk that different rApps will take conflicting decisions at the same instance in time for the same user. Such conflicts between rApps include:

    • • Direct conflicts: different rApps request change for the same parameter.
    • • Indirect conflicts: different rApps request change to different parameters that will create opposite effects.
    • • Implicit conflicts: different rApps request change to different parameters that are not creating any obvious opposite effect but result in an overall network performance degradation, instabilities, etc.

    These conflicts are difficult to mitigate since dependencies are impossible to observe.

    | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-02 | +| Threat title | An attacker exploits rApp vulnerabilities | +| Threat description |

    Vulnerabilities can potentially exist in any rApp. If attackers can find exploitable rApp, they can potentially force a data breach, disrupt the offered network service, and take over another rApp or the non-RT RIC.

    The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 interface, extract sensitive information, etc.

    | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-03 | +| Threat title | An attacker exploits rApps misconfiguration | +| Threat description | Security misconfiguration, such as open ports or enabled unused protocols, can potentially exist in an rApp. If attackers can find exploitable rApp, they can disrupt the offered network service and potentially take over another rApp or the whole non-RT RIC. | + +| | | +|--|------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 interface, extract sensitive information, etc. | +|--|------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-04 | +| Threat title | An attacker bypasses authentication and authorization | +| Threat description | An Attacker can exploit an rApp that has weak or misconfigured authentication and authorization to gain access to the rApp and pose as a tenant. | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-05 | +| Threat title | An attacker deploys and exploits malicious rApp | +| Threat description |

    An untrusted source may intentionally provide a malicious rApp. A trusted source may have a backdoor intentionally inserted in the rApp. If attackers can find exploitable rApp, they can disrupt the offered network service and potentially take over another rApp or the whole non-RT RIC.

    Malicious rApps could impact non-RT RIC functions such as AI/ML model training, A1 policy management, Enrichment information management, Network Configuration Optimization in the purpose of performance degradation, DoS, enrichment data sniffing (UE location, trajectory, navigation information, GPS data, etc.), etc.

    | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-06 | +| Threat title | An attacker bypasses authentication and authorization using an injection attack | +| Threat description | It is possible that an attacker to submit requests without prior authentication and authorization by executing an injection attack to manipulate configurations, access logs, perform remote code execution, etc. | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------| +| Threat ID | T-rAPP-07 | +| Threat title | rApp exploits services | +| Threat description | A malicious rApp or a trusted but compromised rApp can exploit services across the R1 interface | + +#### 7.4.1.8 Threats against PNF + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-PNF-01 | +| Threat title | An attacker compromises a PNF to launch attacks against VNFs/CNFs | +| Threat description |

    A lack of security policies to protect mixed PNF-VNF/CNF deployments could be used to perform attacks against VNFs/CNFs, potentially taking advantage of legacy security used by PNFs and not provided by the virtualization/containerization layer.

    Attackers could use insecure interfaces as injection points and for launching the attacks.

    Attackers could leverage lack of authentication, integrity check mechanisms to tamper software updates to PNFs.

    | +| Threat Type | Information Disclosure, Tampering | +| Vulnerabilities | Vulnerabilities in a PNF deployed in a PNF-VNF/CNF deployments. | +| Impact Type | Confidentiality, Integrity | + +| | | +|------------------------|-----| +| Affected Assets | All | +|------------------------|-----| + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-PNF-01A | +| Threat title | An attacker compromises a PNF to launch Denial of Service attacks against VNFs/CNFs | +| Threat description | A lack of security policies to protect mixed PNF-VNF/CNF deployments could be used to perform attacks against VNFs/CNFs, potentially taking advantage of legacy security used by PNFs and not provided by the virtualization/containerization layer. The attacks on VNF/CNF could lead to denial of service of the VNF/CNF services and function to its dependent functions/elements. | +| Threat Type | Denial of Service | +| Vulnerabilities | Vulnerabilities in a PNF deployed in a PNF-VNF/CNF deployments. | +| Impact Type | Availability | +| Affected Assets | All | + +#### 7.4.1.9 Threats against R1 interface + +The R1 interface facilitates inter-connection between rApps and Non-RT RIC framework supplied by different vendors, and provides a level of abstraction between rApps and Non-RT RIC framework/SMO that can be the consumers and or producers of R1 services. + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-01 | +| Threat title | An attacker gains unauthorized access to R1 services | +| Threat description | “Service management and exposure services Producer” determines whether the Service Producer is authorized to produce the service. An attacker can perform a spoofing attack to gain unauthorized access to R1 services. | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-02 | +| Threat title | Attacker modifies Service Heartbeat message to cause Denial of Service | +| Threat description | Attacker can exploit the Service Heartbeat on the R1 by modifying or inserting heartbeat messages to cause denial of service | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-03 | +| Threat title | Malicious actor bypasses authentication to Request Data | +| Threat description | Attacker can exploit password-based authentication on the R1 to request unauthorized data. Weak password management can easily be exploited. (Certificate-based mutual authentication using TLS and PKI X.509 certificates is recommended). | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-04 | +| Threat title | An attacker bypasses authorization to discover data | +| Threat description | “Data registration and discovery service producer” determines whether the Data Producer is authorized to produce the data types. An attacker can perform a spoofing attack to bypass authorization to discover available data. | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-05 | +| Threat title | An attacker gains unauthorized access to data | +| Threat description | An attacker can perform a spoofing attack to exploit the Data request and subscription service for the purpose to gain unauthorized access to data. | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-06 | +| Threat title | An attacker modifies a Data Request | +| Threat description | Data Consumers consume the “Data request and subscription service” to request data instances or subscribe to them. An attacker can modify a request to force the consumer to receive a different data set then that intended. Without checks, the received data could be processed, leading to erroneous decisions or triggers. | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-R1-07 | +| Threat title | A malicious actor snoops Data Delivery to the Data Consumer | +| Threat description |

    Data delivery messages relate to a particular data request or subscription. The data can be delivered to the Data Consumer in different ways, including:

    • • as part of the payload of a data delivery message,
    • • as a data stream,
    • • from e.g., a REST endpoint, a message bus or object store location.

    An attacker can perform snooping, injection, or modification attacks in the Delivery of Data process.

    | + +#### 7.4.1.10 Threats against A1 interface + +The A1 interface enables the Non-RT RIC function to provide policy-based guidance, ML model management and enrichment information to the Near-RT RIC function for RAN optimization. The Non-RT RIC can provide enrichment information over the A1 interface to support the policy enforcement in the Near-RT RIC. The A1 interface is used for discovery, request and delivery of A1 Enrichment Information and discovery of External Enrichment Information. + +![Diagram showing the A1 interface between Non-RT-RIC and Near-RT-RIC. A double-headed arrow labeled 'A1' connects the Non-RT-RIC box at the top to the Near-RT-RIC box at the bottom.](8a18c8b80acb74b8b0cfc2c8ea43093b_img.jpg) + +``` + +graph TD + Non-RT-RIC[Non-RT-RIC] <-->|A1| Near-RT-RIC[Near-RT-RIC] + +``` + +Diagram showing the A1 interface between Non-RT-RIC and Near-RT-RIC. A double-headed arrow labeled 'A1' connects the Non-RT-RIC box at the top to the Near-RT-RIC box at the bottom. + +Figure 7-4 : A1 interface between the Non-RT RIC and the Near-RT RIC + +| | | +|--------------|------------------------------------------------------| +| Threat ID | T-A1-01 | +| Threat title | Untrusted peering between Non-RT-RIC and Near-RT-RIC | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | Malicious Non-RT-RIC peers with a Near-RT-RIC over the A1 interface, or a malicious Near-RT-RIC peers with a Non-RT-RIC over the A1 interface, due to weak mutual authentication. | +| Threat ID | T-A1-02 | +| Threat title | Malicious function or application monitors messaging across A1 interface | +| Threat description | Internal threat actor can gain access to the messaging across the A1 interface for a MiTM attack to read policy. | +| Threat ID | T-A1-03 | +| Threat title | Malicious function or application modifies messaging across A1 interface | +| Threat description | Internal threat actor can gain access to the messaging across the A1 interface for a MiTM attack to modify or inject policy. This can result in the Near-RT RIC receiving malicious policy. | +| Threat ID | T-A1-04 | +| Threat title | Unauthorized access to Non-RT-RIC- or Near-RT-RIC- resources | +| Threat description | A malicious actor accesses Near-RT-RIC resources or Non-RT-RIC resources over the A1 interface, due to weak service consumer authorization. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | A1 policies [ASSET-D-07], A1 Enrichment Information [ASSET-D-08] | + +#### 7.4.1.11 Threats against application life cycle + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AppLCM-01 | +| Threat title | Compromise of App/VNF/CNF update package integrity prior to onboarding | +| Threat description | Attackers gains access to the SMO to modify the App/VNF/CNF update package to enable a malicious application. | +| Threat type | Tampering; Denial of Service | +| Impact type | Integrity; Availability | +| Affected Asset | ASSET-D-15: App/VNF/CNF software package | +| Threat ID | T-AppLCM-02 | +| Threat title | Compromise of App/VNF/CNF update image integrity during instantiation | +| Threat description | Attacker gains access to the O-Cloud platform to modify the App/VNF/CNF update image to enable a malicious application. | +| Threat type | Tampering; Denial of Service | +| Impact type | Integrity; Availability | + +| | | +|-----------------------|------------------------------------------| +| Affected Asset | ASSET-D-15: App/VNF/CNF software package | +|-----------------------|------------------------------------------| + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AppLCM-03 | +| Threat title | Downgrade attack to vulnerable application version | +| Threat description |

    A software version downgrade attack is a form of attack on a system that makes it abandon a more recent version of a software package in favor of an older, possibly vulnerable, version.

    Malicious actor downgrades an application to enable exploitation of application vulnerabilities.

    | +| Threat type | Denial of Service; Tampering | +| Impact type | Availability; Integrity | +| Affected Asset | ASSET-D-15: App/VNF/CNF software package | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AppLCM-04 | +| Threat title | Attacker exploits missing or improperly defined elements of application's SecurityDescriptor | +| Threat description | Proper and comprehensive definition of the App/VNF/CNF package SecurityDescriptor helps ensure elements of security needed for the App/VNF/CNF package are present. If attackers can find missing or improperly defined elements of an App/VNF/CNF package SecurityDescriptor, they can exploit that to gain unauthorized access to data and services. | +| Threat type | Elevation of Privilege; Denial of Service | +| Impact type | Authorization; Availability | +| Affected Asset | ASSET-D-15: App/VNF/CNF software package | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AppLCM-05 | +| Threat title | Malicious actor modifies application's SecurityDescriptor | +| Threat description | Malicious actor modifies fields of an App/VNF/CNF package SecurityDescriptor to change security elements of the App/VNF/CNF, which could include information on encryption, algorithms, key requirements, firewall rules, etc. An attacker can modify the SecurityDescriptor to cause service disruption and gain unauthorized access to data and services. | +| Threat type | Tampering; Elevation of Privilege; Denial of Service | +| Impact type | Integrity; Authorization; Availability | +| Affected Asset | ASSET-D-15: App/VNF/CNF software package | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AppLCM-06 | +| Threat title | Improper decommissioning of application | +| Threat description | The improper decommissioning of an application can lead to excessive or conflicting resource usage, accidental deletion of pertinent data (such as application data, cryptographic keys, etc.), and misallocation of resources to a malicious application. Credentials or other trust relationships may not be revoked or removed, which leaves an exposure. | + +| | | +|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat type | Denial of Service, Information Disclosure | +| Impact type | Availability, Confidentiality | +| Affected Asset | ASSET-C-02: Near-RT RIC software, ASSET-C-11: Non-RT RIC software, ASSET-C-09: xApps, ASSET-C-10: rApps, ASSET-C-03: O-CU-CP software, ASSET-C-04: O-CU-UP software, ASSET-C-05: O-DU software | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AppLCM-07 | +| Threat title | Improper deletion of application sensitive data | +| Threat description | Adversary can gain access to sensitive data and secrets if an application's data is not securely deleted. This can include access to secure artifacts such as certificates and keys. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | ASSET-D-16: X.509 certificates, ASSET-D-17: Private keys, ASSET-D-32: Cryptographic keys used during secure boot | + +#### 7.4.1.12 Threats against E2 interface + +E2 is a logical interface connecting the Near-RT RIC with an E2 Node as defined in [i.25]. The E2 functions are grouped into the following categories: + +- Near-RT RIC Services +- Near-RT RIC support functions + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-E2-01 | +| Threat title | Untrusted Near-RT-RIC and/or E2 Nodes | +| Threat description | A malicious E2 Node communicates with a Near-RT-RIC over the E2 interface, or a malicious Near-RT-RIC communicates with an E2 Node over the E2 interface, due to weak mutual authentication. | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------| +| Threat ID | T-E2-02 | +| Threat title | Malicious actor monitors messaging across E2 interface | +| Threat description | Threat actor can gain access to the messaging across the E2 interface for a MiTM attack to read messages. | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-E2-03 | +| Threat title | Malicious actor modifies messaging across E2 interface | +| Threat description | Threat actor can gain access to the messaging across the E2 interface for a MiTM attack to modify or inject messages. This can result in the Near-RT RIC and/or the E2 Nodes receiving malicious messages. | + +#### 7.4.1.13 Threats against Y1 interface + +The Near-RT RIC provides RAN analytics information (RAI) services via Y1 service interface. These services can be consumed by Y1 consumers by subscribing to or requesting the RAN analytics information via the Y1 service interface. Y1 consumers may be Application Functions (AFs) which are within an O-RAN trusted domain. AFs outside the O- + +RAN trusted domain may use Y1 services, too. Further details are available in the O-RAN Architecture Description [i.6], clauses 5.1 and 5.4.18. + +![Figure 7-5: RAN analytics information (RAI) services via Y1 service interface. The diagram shows a box labeled 'Near-RT RIC' containing a box labeled 'Y1T' and a box labeled 'RAI producer xApp'. A line labeled 'Y1 API(s)' connects 'Y1 Consumers' to 'Y1T'. A line labeled 'RAI API(s)' connects 'Y1T' to 'RAI producer xApp'.](03d4800d8bb684ec0a03ea93e597bba2_img.jpg) + +``` + +graph TD + Y1Consumers[Y1 Consumers] --- Y1APIS[Y1 API(s)] + subgraph Near-RT_RIC [Near-RT RIC] + Y1T[Y1T] + RAIproducerxApp[RAI producer xApp] + Y1T --- RAIAPIS[RAI API(s)] + RAIproducerxApp --- RAIAPIS + end + +``` + +Figure 7-5: RAN analytics information (RAI) services via Y1 service interface. The diagram shows a box labeled 'Near-RT RIC' containing a box labeled 'Y1T' and a box labeled 'RAI producer xApp'. A line labeled 'Y1 API(s)' connects 'Y1 Consumers' to 'Y1T'. A line labeled 'RAI API(s)' connects 'Y1T' to 'RAI producer xApp'. + +**Figure 7-5 : RAN analytics information (RAI) services via Y1 service interface** + +Malicious Y1 consumers may use their access through the Y1 interface with the intent of accessing, manipulating or negatively impacting the privacy of subscribers, the RAN or the core network. + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-Y1-01 | +| Threat title | Untrusted Near-RT-RIC and Y1 consumers | +| Threat description | A Malicious Y1 consumer communicates with a Near-RT-RIC over the Y1 interface, or a malicious Near-RT-RIC communicates with a Y1 consumer over the Y1 interface, due to weak mutual authentication. | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------| +| Threat ID | T-Y1-02 | +| Threat title | Malicious actor monitors messaging across Y1 interface | +| Threat description | Threat actor can gain access to the messaging across the Y1 interface for a MiTM attack to read messages. | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-Y1-03 | +| Threat title | Malicious actor modifies messaging across Y1 interface | +| Threat description | Threat actor can gain access to the messaging across the Y1 interface for a MiTM attack to modify or inject messages. This can result in the Near-RT RIC and/or the Y1 consumers receiving malicious messages. | + +### 7.4.2 Threats against O-CLOUD + +Virtualization and containerization technologies in O-RAN introduce the following relevant threats: + +#### 7.4.2.1 Generic Threats + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-01 | +| Threat title | Software flaw attack | +| Threat description |

    Code of host OS, Hypervisor/Container Engine and VNF/CNF can include flaws that an attacker can exploit if they are present.

    As O-RAN software components relies on opensource software, opensource libraries, 3rd party components. Vulnerability in any of these software components likely to allow attacker to exploit O-CLOUD environment. This could lead attacker to carry out to malicious activities, such as:

    • • Compromise of the underlying VM/Container
    • • Exploit host access via Escape to Host
    • • Take advantage of weak identity and access management policies to attempt to elevate privileges
    • • Execute adversary-controlled code
    • • Enable an adversary to move from a virtualized environment, such as within a virtual machine or container, onto the underlying host
    | +| Threat type | Spoofing, Tampering, Information disclosure, Elevation of Privilege | +| Impact type | Authenticity, Integrity, Confidentiality, Authorization | +| Affected Asset | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-02 | +| Threat title | Malicious access to exposed services using valid accounts | +| Threat description |

    Access to valid accounts to use the O-Cloud services is often a requirement, which could be obtained through credential pharming or by obtaining the credentials from users after compromising the network.

    Adversaries may obtain and abuse credentials of existing accounts as a means of gaining initial access, persistence, privilege escalation, or defense evasion. Compromised credentials may be used to bypass access controls placed on various resources on O-Cloud.

    Compromised credentials may also grant an adversary increased privilege to specific O-Cloud services or access to restricted areas of the O-Cloud network.

    Access may be also gained through an exposed service that doesn't require authentication. In containerized environments, this may include an exposed Docker API, Kubernetes API server, kubelet, or web application such as the Kubernetes dashboard.

    | +| Threat type | Spoofing, Tampering, Information disclosure, Elevation of Privilege | +| Impact type | Authenticity, Integrity, Confidentiality, Authorization | +| Affected Asset | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-03 | +| Threat title | Untrust binding between the different O-Cloud layers | +| Threat description |

    One major challenge in virtualized architectures and especially in O-Cloud is to prove that a particular VM/Container runs on top of a specific Hypervisor/Container Engine. More specifically, it is necessary to assure that a trusted VM/Container is executed on a particular trusted Hypervisor/Container Engine, whereas the Hypervisor/Container Engine's trust state relies on an attestation that considers the entire corresponding hard and software stack. More precisely, this includes all hardware chips, firmware, OS and Hypervisor/Container Engine components that are relevant for the Hypervisor/Container Engine's trust state determination.

    If it is not possible to establish a correlation between VM/Container and Hypervisor/Container Engine, an attacker is able to make use of a trusted VM/Container that runs on top of an untrusted

    | + +| | | +|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Hypervisor/Container Engine and it would be impossible to detect any interference made by the malicious Hypervisor/Container Engine, e.g. intercepting communication, replacing strong or using weak cryptographic keys, etc. Similarly, trustworthiness in the service-layer might only be established if there is a mechanism to determine that only trusted VNFs/CNFs, w.r.t trusted VM/Container's, are running on specific trusted Hypervisors/Container Engines that are part of the service-provisioning-chain. | +| Threat type | Tampering, Information disclosure | +| Impact type | Integrity, Confidentiality | +| Affected Asset | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-04 | +| Threat title | Lack of Authentication & Authorization in interfaces between O-Cloud components | +| Threat description |

    O-Cloud deploys CNF applications as containers in a cluster of physical nodes which may be spanned across geographical locations. Owing to the Service Based Architecture of CNFs, this introduces several service endpoints communicating across each other over the network (container to container, container to cloud infrastructure component) and it is fairly difficult to distinguish between a service terminating an external interface and a service exposing only an internal interface.

    Multi-tenant deployments and deployments in public cloud also require the CNF applications to run alongside unknown entities. In such deployment scenarios, CNF service endpoints with no authentication/weak authentication expose risk of attack that can impact the availability of service and the CNF.

    Lack of proper authentication in interfaces exposed by CNF services, introduces threats of lateral movement where a compromised container/rogue container

    • • can compromise the availability of internal service by bringing down the internal service and perform lateral movement of attack by exploiting the availability of other such services
    • • can compromise the confidentiality of the internal service by extracting critical application data
    | +| Threat type | Information disclosure, Denial of Service | +| Impact type | Availability, Confidentiality | +| Affected Asset | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-05 | +| Threat title | Unsecured credentials and keys | +| Threat description |

    Adversaries may search compromised O-RAN NFs, VL, orchestration layer or hardware to find and obtain insecurely stored credentials. These credentials can be stored and/or misplaced in many locations on the O-cloud platform, including plaintext files (e.g. Bash History), operating system or application-specific repositories (e.g. Credentials in Registry), or other specialized files/artifacts (e.g. Private Keys) [i.22].

    Bash History: Adversaries may search the bash command history on compromised systems for insecurely stored credentials.

    Credentials in registry: Adversaries may search the Registry on compromised systems for insecurely stored credentials.

    Private Keys: Adversaries may search for private key certificate files on compromised systems for insecurely stored credentials. Private cryptographic keys and certificates are used for authentication, encryption/decryption, and digital signatures; Common key and certificate file extensions include: .key, .pgp, .gpg, .ppk, .p12, .pem, .pfx, .cer, .p7b, .asc.

    | + +| | | +|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------| +| | Adversary tools have been discovered that search compromised systems for file extensions relating to cryptographic keys and certificates. | +| Threat type | Tampering, Information disclosure, and Elevation of privilege | +| Impact type | Integrity, Confidentiality, Authorization | +| Affected Asset | Private keys and credentials | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-GEN-06 | +| Threat title | Sensitive application data cache exploitation | +| Threat description |

    Most of the applications use data that is sensitive in nature which needs to be secured. And it is common for these applications to cache such sensitive data, after retrieving the data from a secure storage. This caching occurs in various forms: within application memory, in persistent file systems, or in ephemeral file systems (For example, non-persistent container file system).

    For a VNF, the application can cache the sensitive data in its memory which is non-persistent (erased when the application ceases to exist) or in the persistent virtual machine file system.

    For a CNF, the application can store the sensitive data in its memory which is non-persistent (erased when the application/microservice ceases to exist) or in the non-persistent container file system, or in the persistent host file system, provided the application has the necessary privileges to access host file system.

    The sensitive data components that are cached by applications could be of different types which are used as authentication keys, session keys, passwords, tokens, etc.

    The storage of sensitive data in the application cache is used to improve performance of the applications and keeping the sensitive information readily available to the applications for faster initialization, re-initialization or recovery.

    An example of faster recovery/re-initialization is a scenario where a TLS client establishes a TLS session with a server and stores the client certificate and corresponding private key in the application cache. If the TLS session is terminated unexpectedly (For example, due to network error conditions), the TLS client uses the cached client certificates and private key for recovering / re-establishing the TLS session, instead of retrieving the information from a more secure, but slower, storage solution.

    While leveraging application cache is indispensable for significant performance gains, it also presents a notable security risk [i.28], [i.29]. The sensitive data stored in application cache would be a primary target from attackers/threat actors [i.30], who can exploit this information to penetrate deeper into O-RAN network functions.

    To counter this threat, a “Defense in depth” approach is essential. This approach encompasses multiple security layers designed to mitigate risks associated with application caches, focusing on strong encryption, strict access management and anomaly detection to protect sensitive data effectively.

    | +| Threat type | Tampering, Information disclosure | +| Impact type | Integrity, Confidentiality | +| Affected Asset | Certificates, private keys, credentials and other application specific sensitive data | + +#### 7.4.2.2 Threats concerning VMs/Containers + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VM-C-01 | +| Threat title | Abuse of a privileged VM/Container | +| Threat description |

    It's possible to run VMs/Containers with unintended configurations. Such misconfigurations can help the adversaries to compromise even strongest of VM/Container isolation measures.

    Such misconfigurations scenarios include:

    • • A VMs/Containers can be configured to have more privileges than what is actually required (e.g. settings that give it unnecessary, and perhaps unplanned, privileges). For example, an attacker with access to such a container, can use it to gain higher privileges on host, perform un-authorized operations and get to anything that the host, or any of the containers running on that host, can reach.
    • • A VMs/Containers have unintended read/write access to a directory on host filesystem. This could allow an attacker to perform unauthorized modifications to the contents, create symbolic links to any directories or files not directly exposed by the hostPath, install SSH keys, read secrets mounted to the host, and take other malicious actions.
    | +| Threat type | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | +| Impact type | Authenticity, Integrity, Confidentiality, Availability and Authorization | +| Affected Asset | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VM-C-02 | +| Threat title | VM/Container escape attack | +| Threat description |

    VNF/CNF deployed on the same physical machine as tenants share the same host kernel and host OS resources. Lack of strong isolation between the VMs/Containers and the host allows for a potential risk of a rogue VM/Container escaping the VM/Container confinement and impacting other co-hosted VMs/Containers. In others, an attacker may deploy a new malicious VM/Container configured without network rules, user limitations, etc. to bypass existing defenses within O-Cloud infrastructure.

    Attacker deploys malicious VM/Container to escapes the host (Hypervisor/Container Engine/Host OS) and reaches the server's hardware, then the malicious VM/Container can gain root access to the whole server where it resides. This gives the malicious VM/Container full control on all the VMs/Containers hosted on the same hacked server. This could allow an attacker to undermine the confidentiality, integrity and/or availability of VNFs/CNFs resources.

    Containers can be deployed by various means, such as via Docker's create and start APIs or via a web application such as the Kubernetes dashboard or Kubeflow. Adversaries may deploy containers based on retrieved or built malicious images or from benign images that download and execute malicious payloads at runtime.

    When a malicious VM/Container escapes isolation, it can gain full control over the underlying host and cause any of the below serious threats:

    • • Attacker would gain the ability to mount attacks on the host or compromise the host functionalities
    • • Compromise the confidentiality & integrity of co-hosted VMs/Containers and tenants
    • • Launch DDOS attacks on co-hosted VMs/Containers and host services thereby degrading their performance
    • • Introduce new vulnerabilities in host to be used for future attacks
    • • Lack of network segmentation could potentially expose other VMs/Containers in the environment to attack. An example of this could be reconnaissance, exploitation and subsequent lateral movement to another host within the cluster.
    | +| Threat type | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | +| Impact type | Authenticity, Integrity, Confidentiality, Availability and Authorization | +| Affected Asset | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +![Figure 7-6: Illustration of the VM/Container escape attack. The diagram shows a stack of layers: VM(s)/Container(s) at the top, followed by Near RT RIC, O-CU, and O-DU. Below these is the Hypervisor or Container Engine, then the Host OS, and finally Hardware resources at the bottom. Red arrows indicate the attack path: 1. Attack from VM(s)/Container(s) to Near RT RIC. 2. Attack from Near RT RIC to Hypervisor or Container Engine. 3. Attack from Hypervisor or Container Engine to Host OS. 4. Attack from Host OS to O-CU and O-DU.](19d0cb6c7e5666917cb4f7c1b78af8c4_img.jpg) + +Figure 7-6: Illustration of the VM/Container escape attack. The diagram shows a stack of layers: VM(s)/Container(s) at the top, followed by Near RT RIC, O-CU, and O-DU. Below these is the Hypervisor or Container Engine, then the Host OS, and finally Hardware resources at the bottom. Red arrows indicate the attack path: 1. Attack from VM(s)/Container(s) to Near RT RIC. 2. Attack from Near RT RIC to Hypervisor or Container Engine. 3. Attack from Hypervisor or Container Engine to Host OS. 4. Attack from Host OS to O-CU and O-DU. + +Figure 7-6 : Illustration of the VM/Container escape attack + +| Threat ID | T-VM-C-03 | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | VM/Container data theft | +| Threat description |

    The VNF/CNF remotely stores sensitive data (e.g. passwords, private keys, subscription data, logs) on the logical volume that the IMS/DMS allocates to the VNF/CNF. An attacker can retrieve/manipulate these data if they have been stored in an insecure way (e.g. clear text, unsalted hashes) or a malware is installed on the logical volume that the VIM allocates to the VNF/CNF.

    Container example: Adversaries may attempt to discover containers and other resources that are available locally within O-Cloud. Other resources may include images, deployments, pods, nodes, and other information such as the status of a cluster. These resources can be viewed within web applications such as the Kubernetes dashboard or can be queried via the Docker and Kubernetes APIs. In Docker, logs may leak information about the environment, such as the environment's configuration, which services are available, and what cloud provider the victim may be utilizing. The discovery of these resources may inform an adversary's next steps in the environment, such as how to perform lateral movement and which methods to utilize for execution.

    | +| Threat type | Tampering, Information disclosure | +| Impact type | Integrity, Confidentiality | +| Affected Asset | Images, environment's configuration, and other information such as the status of a cluster | + +| Threat ID | T-VM-C-04 | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | VM/Container migration attacks | +| Threat description |

    The attacks that exploit VM/Container migration can be divided into two subcategories based on the target plane:

    1. 1. Control Plane Attacks: These attacks target the module that is responsible for handling the migration process on a server which is called the migration module that is found in the host. By exploiting a bug in the migration module software, the attacker can hack the server and take full control over the migration module. This gives the attacker the ability to launch malicious activities including the following:
      1. a. Migration Flooding: The attacker moves all the VMs/Containers that are hosted on the hacked server to a victim server that does not have enough resource capacity to host all the moved VMs/Containers. This causes a denial of service for the VNFs/CNFs running in the VMs/Containers of the victim server as there will not be enough resources to satisfy the demands of all the hosted VMs/Containers leading into VM/Container performance degradation and VM/Container crashes.
      2. b. False Resource Advertising: The hacked server claims that it has a large resource slack (a large amount of free resources). This attracts other servers to off-load some of their VMs/Containers to the hacked server so that the O-Cloud workload gets distributed over the O-Cloud servers. After moving VMs/Containers from other servers to the hacked server, the attacker can exploit other vulnerabilities to break into the offloaded
    | + +| | | +|----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |

    VMs/Containers as now these VMs/Containers are placed on a server that is under the control of the attacker.

    2. Data Plane Attacks: These constitute the second type of VM/Container migration attacks and those attacks target the network links over which the VM/Container is moved from a server to another. Such data plane attacks include the MitM where an attacker sniffs the packets that are exchanged between the source and destination servers and reads the migrated memory pages. The attacker can monitor and/or modify the received packets while continuing to forward them to victim VM/Container resides so that the victim does not detect that any malicious activity is going on.

    | +| Threat type | Tampering, Information disclosure, Denial of Service | +| Impact type | Integrity, Confidentiality, Availability | +| Affected Asset | VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +![Figure 7-7: Illustration of the migration flooding attack. The diagram shows an attacker (1) sending a large number of migration requests (3) to a victim server. The victim server's Hypervisor or Container Engine is overwhelmed by the flood of requests, leading to a denial of service. The victim server's resources (O-DU, O-CU, Near RT RIC) are shown as being unable to handle the flood.](72b56c480881d5956f194cd3d9d2fa2a_img.jpg) + +Attacker migrates more VMs/Containers than the capacity of the victim server + +1: Attacker sends migration requests to the victim server. + +2: Victim server's Hypervisor or Container Engine receives the requests. + +3: Attacker sends more requests than the victim server can handle, causing a denial of service. + +Victim server resources: O-DU, O-CU, Near RT RIC. + +Figure 7-7: Illustration of the migration flooding attack. The diagram shows an attacker (1) sending a large number of migration requests (3) to a victim server. The victim server's Hypervisor or Container Engine is overwhelmed by the flood of requests, leading to a denial of service. The victim server's resources (O-DU, O-CU, Near RT RIC) are shown as being unable to handle the flood. + +Figure 7-7 : Illustration of the migration flooding attack + +![Figure 7-8: Illustration of the false resource advertising attack. The diagram shows an attacker (1) sending false resource advertisements (2) to the victim server. The victim server's Hypervisor or Container Engine is misled by the false advertisements, leading to a denial of service. The victim server's resources (O-DU, O-CU, Near RT RIC) are shown as being unable to handle the false advertisements.](ebc5aa6c7cde5009551538622ea13aa4_img.jpg) + +1: Attacker sends false resource advertisements to the victim server. + +2: Victim server's Hypervisor or Container Engine receives the false advertisements. + +3: Attacker sends more false advertisements than the victim server can handle, causing a denial of service. + +4: Victim server's resources (O-DU, O-CU, Near RT RIC) are misled by the false advertisements. + +Victim server resources: O-DU, O-CU, Near RT RIC. + +Figure 7-8: Illustration of the false resource advertising attack. The diagram shows an attacker (1) sending false resource advertisements (2) to the victim server. The victim server's Hypervisor or Container Engine is misled by the false advertisements, leading to a denial of service. The victim server's resources (O-DU, O-CU, Near RT RIC) are shown as being unable to handle the false advertisements. + +Figure 7-8 : Illustration of the false resource advertising attack + +![Figure 7-9: Illustration of the migration MITM attack. The diagram shows two server architectures: 'Hacked Server' and 'Victim server'. Both servers have a stack of layers: VM(s)/Container(s), Hypervisor or Container Engine, Host OS, and Hardware resources. The Hacked Server has a 'Near RT RIC' and an 'O-CU' VM/Container, while the Victim server has an 'O-CU' and a 'Near RT RIC' VM/Container. An attacker (hacker icon) is shown compromising the O-DU VM/Container on the Hacked Server. A red arrow indicates the attacker's intent to migrate the O-DU VM/Container to the Victim server. A green arrow shows the User's connection to the Victim server's O-DU. A red 'X' marks the User's connection to the Hacked Server's O-DU, indicating a denial of service or interception.](05c384f957870c7d81e5302d4ab040ab_img.jpg) + +Figure 7-9: Illustration of the migration MITM attack. The diagram shows two server architectures: 'Hacked Server' and 'Victim server'. Both servers have a stack of layers: VM(s)/Container(s), Hypervisor or Container Engine, Host OS, and Hardware resources. The Hacked Server has a 'Near RT RIC' and an 'O-CU' VM/Container, while the Victim server has an 'O-CU' and a 'Near RT RIC' VM/Container. An attacker (hacker icon) is shown compromising the O-DU VM/Container on the Hacked Server. A red arrow indicates the attacker's intent to migrate the O-DU VM/Container to the Victim server. A green arrow shows the User's connection to the Victim server's O-DU. A red 'X' marks the User's connection to the Hacked Server's O-DU, indicating a denial of service or interception. + +**Figure 7-9 : Illustration of the migration MITM attack** + +| Threat ID | T-VM-C-05 | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Changing virtualization resource without authorization | +| Threat description |

    IMS/DMS which manage the Virtualization layer is responsible for assigning virtualized resource as requested.

    There are several ways to cause a DoS attack for the VNFs/CNFs:

    • • If IMS/DMS are compromised or the O2 interface is not securely protected, an attacker who compromised the IMS/DMS or breached the O2 interface can change the virtualized resource used by a VNF/CNF by manipulating the allocation of virtualized resource. For example, when an instantiated VNF/CNF is running, adversaries having access to a compromised IMS/DMS or adversaries breaching the insecure O2 interface can misguide the Virtualization layer to reduce the resource of or delete a VM/Container on which a VNF/CNF is running. This can result in the reliability, availability or even illegal termination of a VNF/CNF and hence the denial of service.
    • • Hardware resource configuration and state information (e.g. events) exchange is performed through O2 interface. If the IMS is compromised or the O2 interface is not securely protected, an attacker who compromised the IMS or breached the O2 interface can tamper the hardware configuration and state information so that the virtualized resource supported by the hardware layer becomes unreliable. For example, adversaries having access to a compromised IMS or adversaries breaching the insecure O2 interface can misguide the O-Cloud platform to detach a hardware accelerator from a VNF/CNF.
    • • Adversaries having access to a compromised virtualization layer can change the virtualization resource used by the instantiated VNF/CNF without authorization,
    • • A malicious VM/Container deployed for one instance of a VNF/CNF on a host can illegally occupy the resources of the instantiated VNF/CNF deployed on the same host, resulting in resource limitation of the instantiated VNF/CNF

    In this type of attacks, the extra allocation of resources for the malicious VM/Container comes at the expense of the other VMs/Containers that share the same server as the malicious VM/Container, where these victim VMs/Containers get allocated less share of resources than what they should actually obtain, which in turn degrades their performance.

    | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +![Figure 7-10: Illustration of the Theft-of-Service/DoS Attack. The diagram shows a stack of layers: VM(s)/Container(s) (Near RT RIC, O-CU, O-DU), Hypervisor or Container Engine, Host OS, and Hardware resources. A malicious VM/Container is running on the hardware resources, and a victim VM/Container is also running. An attacker (1) is shown injecting a malicious VM/Container into the O-DU layer. The attacker then moves the malicious VM/Container to the Host OS layer (2) and finally to the Hardware resources layer (3).](7c187af9b826881551ade314507ed45c_img.jpg) + +Figure 7-10: Illustration of the Theft-of-Service/DoS Attack. The diagram shows a stack of layers: VM(s)/Container(s) (Near RT RIC, O-CU, O-DU), Hypervisor or Container Engine, Host OS, and Hardware resources. A malicious VM/Container is running on the hardware resources, and a victim VM/Container is also running. An attacker (1) is shown injecting a malicious VM/Container into the O-DU layer. The attacker then moves the malicious VM/Container to the Host OS layer (2) and finally to the Hardware resources layer (3). + +**Figure 7-10 : Illustration of the Theft-of-Service/DoS Attack** + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VM-C-06 | +| Threat title | Failed or incomplete VNF/CNF termination or releasing of resources | +| Threat description |

    A malicious VNF/CNF is instantiated in the O-Cloud infrastructure to access data not erased from a terminated VNF/CNF or any VNF/CNF that has released resources. Data could include application data, cryptographic keys...

    Abuse of resources allocation in the O-Cloud infrastructure to allocate to a malicious VNF/CNF the virtual resources released from a terminated VNF/CNF or from a VNF/CNF that has released resources after a move or a scaling process.

    Inclusion of concealed software in the O-Cloud infrastructure to prevent the deletion/erasure of data and states of the VNF/CNF that has been terminated.

    | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | Sensitive data (e.g. passwords, private keys, subscription data, logs), VNFs/CNFs (Near RT RIC, O-CU, O-DU) software and data | + +#### 7.4.2.3 Threats concerning VM/Container images + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-IMG-01 | +| Threat title | VM/Container images tampering | +| Threat description |

    An attacker can inject malicious code or tamper the information inside the unprotected image during on boarding. Then after the instantiation of the VNF/CNF, the tampered code can cause DoS, information stealing, frauds and so on. There are several attacks categories belonging to this threat. Such attacks include:

    • Build machine attacks: If an attacker can modify or influence the way a VM/Container image is built, they could insert malicious code that will subsequently get run in the production environment.
    • Supply chain attacks: Once the VM/Container image is built, it gets stored in a registry, and it gets retrieved or “pulled” from the registry at the point where it’s going to be run. An attacker who can replace an image or modify an image between build and deployment could run arbitrary code on your deployment.
    | +| Threat type | Tampering, Information disclosure | + +| | | +|----------------|----------------------------| +| Impact type | Integrity, Confidentiality | +| Affected Asset | VM/Container images | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-IMG-02 | +| Threat title | Insecure channels with images repository | +| Threat description | Images often contain sensitive components like an organization's proprietary software, and embedded secrets and administrator credentials. If connections to registries are performed over insecure channels, man-in-the-middle attacks could intercept network traffic and therefore the contents integrity and confidentiality of images may be compromised. There is also an increased risk of man-in-the-middle attacks that could intercept network traffic intended for registries and steal developer or administrator credentials within that traffic. Thus, could be used to provide fraudulent or outdated images to orchestrators, etc. | +| Threat type | Tampering, Information disclosure | +| Impact type | Integrity, Confidentiality | +| Affected Asset | VMs/Containers images | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-IMG-03 | +| Threat title | Secrets disclosure in VM/Container images | +| Threat description |

    There are scenarios which benefit from including configuration and secrets, such as passwords or credentials in VNFs/CNFs images. For e.g. VMs/Containers require to be able to connect to other VMs/Containers within the deployment as well as with external entities. All these connections need to be authenticated and secured. One way of achieving this is to provide the requisite secrets or keys to the VMs/Containers which allow them to authenticate, be authenticated, secure the communication channel and signature. A common but in-secure means of providing secrets to the VMs/Containers is by packaging the secrets or the keys with the image itself. There is the risk that the same can be extracted, read or manipulated before the VM/Container is deployed and the secret used.

    With a long supply chain, VM/Container images are vulnerable to outside scrutiny. With VM/Container images containing secrets or keys, this becomes a serious threat vector. Adversaries can extract them by obtaining a copy of the image and they can be potentially shared with third parties for illicit gain.

    • • Secrets embedded within a VM/Container image can be stolen.
    • • Secrets embedded within a VM/Container image can be modified

    Compromised private keys and algorithms used for image signing due to poor key protection/management/design could undermine the security of image signing process.

    | +| Threat type | Spoofing, Tampering, Information disclosure | +| Impact type | Authenticity, Integrity, Confidentiality | +| Affected Asset | VM/Container images | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-IMG-04 | +| Threat title | Build image on VL | +| Threat description |

    Adversaries may build a VM/Container image directly on the VL to bypass defenses that monitor for the retrieval of malicious images from a registry.

    Container example: A remote build request may be sent to the Docker API that includes a Dockerfile that pulls a vanilla base image, such as alpine, from a public or local registry and then builds a custom image upon it.

    An adversary may take advantage of that build API to build a custom image on the host that includes malware downloaded from their C2 server, and they then may deploy container using that custom image.

    | + +| | | +|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | If the base image is pulled from a public registry, defenses will likely not detect the image as malicious since it's a vanilla image. If the base image already resides in a local registry, the pull may be considered even less suspicious since the image is already in the environment. | +| Threat type | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | +| Impact type | Authenticity, Integrity, Confidentiality, Availability and Authorization | +| Affected Asset | VM/Container images | + +#### 7.4.2.4 Threats concerning the virtualization layer (Host OS-Hypervisor/Container engine) + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VL-01 | +| Threat title | VM/Container hyperjacking attack | +| Threat description |

    VMs/Containers run on host machines, and it is needed to ensure that those hosts (Hypervisor/Container Engine/Host OS- are not running vulnerable code (for example, old versions of components with known vulnerabilities).

    Hyperjacking is an attack in which adversaries gain control over the host of a server or install a malicious Hypervisor/Container Engine/Host OS and exploit that to run malicious applications on the VM/Container that run on top of the host. This would enable the attacker to control all the VMs/Containers running on the host.

    Hyperjacking involves installing a malicious, fake the Hypervisor/Container Engine/Host OS that can manage the entire server system. If the attacker gains access to the Hypervisor/Container Engine/Host OS, everything that is connected to that server can be manipulated. The Hypervisor/Container Engine/Host OS represents a single point of failure when it comes to the security and protection of sensitive information.

    For a hyperjacking attack to succeed, an attacker would have to take control of the Hypervisor/Container Engine/Host OS by the following methods:

    • Injecting a rogue Hypervisor/Container Engine or Host OS beneath the original hypervisor or on top of an existing Hypervisor/Container Engine/Host OS
    • Directly obtaining control of the original Hypervisor/Container Engine or Host OS
    • Running a rogue hypervisor on top of an existing hypervisor
    | +| Threat type | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | +| Impact type | Authenticity, Integrity, Confidentiality, Availability and Authorization | +| Affected Asset | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +![Diagram illustrating the VM/Container hyperjacking attack. An attacker (1) injects a Rogue Hypervisor or Container Engine and a Rogue Host OS into the existing Hypervisor or Container Engine and Host OS layers. This allows the attacker to control the VM(s)/Container(s) running on top, specifically targeting the Near RT RIC, O-CU, and O-DU components. The attack is shown as a red box labeled '2' in the O-CU layer.](ffef3237049b682a6291096b92367295_img.jpg) + +The diagram illustrates the VM/Container hyperjacking attack. It shows a stack of layers: Hardware resources at the bottom, followed by Host OS, Hypervisor or Container Engine, and VM(s)/Container(s) at the top. The VM(s)/Container(s) layer contains three components: Near RT RIC, O-CU, and O-DU. An attacker (1) is shown injecting a Rogue Hypervisor or Container Engine and a Rogue Host OS into the existing Hypervisor or Container Engine and Host OS layers. This allows the attacker to control the VM(s)/Container(s) running on top, specifically targeting the Near RT RIC, O-CU, and O-DU components. The attack is shown as a red box labeled '2' in the O-CU layer. + +Diagram illustrating the VM/Container hyperjacking attack. An attacker (1) injects a Rogue Hypervisor or Container Engine and a Rogue Host OS into the existing Hypervisor or Container Engine and Host OS layers. This allows the attacker to control the VM(s)/Container(s) running on top, specifically targeting the Near RT RIC, O-CU, and O-DU components. The attack is shown as a red box labeled '2' in the O-CU layer. + +Figure 7-11 : Illustration of the VM/Container hyperjacking attack + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VL-02 | +| Threat title | Boot tampering | +| Threat description |

    The bootloader of the virtualization layer (Host OS, Hypervisor, Container Engine) for VNF/CNF may be maliciously tampered by an attacker, e.g. the attacker compromises hypervisor or host OS to tamper the bootloader of guest OS (in case of VM) or Container.

    In a O-Cloud environment any failure during the boot sequence can result in a number of situations that need to be handled by the NFO/FOCOM:

    • • failure of the physical machine to start at all
    • • physical machine entering a safe-mode
    • • physical machine continuing boot regardless of the integrity measurements
    | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-VL-03 | +| Threat title | Attack internal network services | +| Threat description |

    In addition to attacking the network between containers, adversaries can also attack supporting services such as DNS service, which is only reachable from within the cluster network. The highly distributed nature of containers requires shared services for example for coordination and service discovery. An attacker can target these services to degrade services. For example, a denial-of-service against the service discovery infrastructure could prevent O-Cloud to react to changing resource requirements properly. Thus, O-Cloud may no longer be able to scale appropriately to sudden demand spikes [i.16].

    | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Software components at runtime and their associated data | + +#### 7.4.2.5 Threats concerning O-Cloud interfaces + +##### 7.4.2.5.1 O2 interface + +Two main interfaces are defined in O-RAN WG6 specification and identified as critical assets of O-Cloud, i.e. interfaces O2 between O-Cloud and SMO. The threats on these interfaces are as follows. + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O2-01 | +| Threat title | MitM attacks on O2 interface between O-Cloud and SMO | +| Threat description |

    If the interface O2 interface is not protected, an attacker can attack all the requests/responses sent between the O-Cloud and the SMO (FOCOM and NFO).

    For example, the attacker can tamper/alter/disclose requests and services (See ‘Critical services’ in 2.3) sent over O2 between O-Cloud and SMO, hence the virtualized resource or relevant status information is not as requested. This affects the normal operation of the O-Cloud, and even causes DoS attacks, information leakage.

    | + +| | | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |

    An attacker can tamper the specific assignment of virtualized resources to cause resource assignment errors or an attacker can intercept virtualized resources state information leading to information disclosure.

    An attacker can compromise IMS to tamper with the hardware state information (e.g. deleting hardware alarm information) to affect the hardware's operation or to result in information disclosure (e.g. an attacker can get the hardware configuration from the compromised IMS. Then, the attacker can attack the hardware according to the configuration such as CPU type, memory size etc.). An attacker can also tamper or intercept the hardware resource configuration and state information if the configuration and state information are transmitted using an insecure protocol on the O2 interface.

    | +| Threat type | Tampering, Information disclosure, Denial of Service | +| Impact type | Integrity, Confidentiality, Availability | +| Affected Asset | Telemetry, provisioning, logs, software management, performance information | + +##### 7.4.2.5.2 O-Cloud API + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OCAPI-01 | +| Threat title | MitM attacks on O-Cloud interface between VNFs/CNFs and the virtualization layer | +| Threat description |

    An attacker can attack an instantiated VNF/CNF through a compromised virtualization layer. For example, cryptographic keys or other security critical data of an instantiated VNF/CNF could be stolen by an attacker with access to the virtualization layer, or the virtualized resource provided by the Virtualization layer to the instantiated VNF/CNF can be manipulated or the bootloader of Guest OS (in case of VM) or Container of an instantiated VNF/CNF can be tampered by an attacker via a compromised virtualization layer.

    | +| Threat type | Tampering, Information disclosure, Denial of Service | +| Impact type | Integrity, Confidentiality, Availability | +| Affected Asset | Host OS, Hypervisor/Container Engine and VNFs/CNFs (Near RT RIC, O-CU, O-DU) | + +#### 7.4.2.6 Threats concerning hardware resources + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-HW-01 | +| Threat title | Cross VM/Container side channel attacks | +| Threat description |

    In a typical cross-VM/Container side channel attack scenario, an adversary places a malicious VM/Container co-resident to the target VM/Container so that they share the same hardware resources. Then, the attacker extracts useful information such as cryptographic keys from the target VM/Container to use them for traffic eavesdropping and man-in-the-middle attacks. Through the side channel attack, an attacker sharing the same cache as the victim can monitor the cache access behavior of the victim. For example, the attacker is able to monitor cache timing information by measuring the execution of different operations on the victim's VM/Container. Generally, the attacker exploits timings in the shared high-level cache memory. However, power consumption or electromagnetic leaks can also be used as a vector to launch side channel attacks.

    In the virtual environment, prior to the cross-VM/Container side channel attack, the attacker needs to identify the target VM/Container's location and place a malicious VM/Container co-resident with the target. Later, that attacker may use the maliciously placed VM/Container to extract information from the target VM/Container with the side channel attack.

    Hardware vulnerabilities in processors can also have a large impact on O-Cloud security. Flaws in chip design can result in the compromise of tenant information in the cloud through side-channel attacks [i.24].

    | + +| | | +|----------------|--------------------------------------------------------------------------------------------------------------------------| +| Threat type | Tampering, Information disclosure, Denial of Service | +| Impact type | Integrity, Confidentiality, Availability | +| Affected Asset | Sensitive data (e.g. passwords, private keys, subscription data, logs), VNFs/CNFs (Near RT RIC, O-CU, O-DU) related data | + +![Figure 7-12: Illustration of a cross VM/Container side channel attack. The diagram shows a stack of layers: VM(s)/Container(s) (containing Near RT RIC, O-CU, and O-DU), Hypervisor or Container Engine, Host OS, and Hardware resources (containing a Shared cache). An attacker (1) is shown at the top, with an arrow pointing to the VM(s)/Container(s) layer. A second arrow (2) points from the VM(s)/Container(s) layer down to the Shared cache in the Hardware resources layer, indicating a side channel attack.](6407f29eddba81826c544401f1003dcc_img.jpg) + +Figure 7-12: Illustration of a cross VM/Container side channel attack. The diagram shows a stack of layers: VM(s)/Container(s) (containing Near RT RIC, O-CU, and O-DU), Hypervisor or Container Engine, Host OS, and Hardware resources (containing a Shared cache). An attacker (1) is shown at the top, with an arrow pointing to the VM(s)/Container(s) layer. A second arrow (2) points from the VM(s)/Container(s) layer down to the Shared cache in the Hardware resources layer, indicating a side channel attack. + +Figure 7-12 : Illustration of a cross VM/Container side channel attack + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-HW-02 | +| Threat title | MitM attacks on the interface between virtualization layer and hardware | +| Threat description | An attacker can utilize the vulnerabilities of hardware (e.g. Meltdown and Specter of CPU in host) to attack virtualization layer and/or VNFs/CNFs through this interface, resulting in tampering, information disclosure or DoS. | +| Threat type | Tampering, Information disclosure, Denial of Service | +| Impact type | Integrity, Confidentiality, Availability | +| Affected Asset | All assets | + +#### 7.4.2.7 Threats concerning O-Cloud management (SMO, NFO, FOCOM) + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ADMIN-01 | +| Threat title | Denial of service against NFO/FOCOM | +| Threat description |

    A denial-of-service attack against the NFO/FOCOM can interfere with the ability of operators to control and maintain their deployments. This can lead to the inability to react to changing resource requirements. In addition, the NFO/FOCOM is the external API to interact with the O-Cloud platform. Thus, other services may become inaccessible as well. For example, operators may be unable to retrieve logs, telemetry data. An attacker could use this opportunity to hide additional attacks on VM/Container instances.

    In addition, an attacker on the NFO/FOCOM could prevents the O-Cloud software update (VNFs/CNFs, VL) to exploit a known security flaw in the O-Cloud software.

    | +| Threat type | Denial of Service | +| Impact type | Availability | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Affected Asset | VM/Container images, VNF/CNF, host OS, Hypervisor/Container Engine software | +| Threat ID | T-ADMIN-02 | +| Threat title | Abuse a O-Cloud administration service | +| Threat description |

    Usually, the SMO including NFO/FOCOM is exposed to the tenant in a web front-end or REST API. In case these interfaces contain software vulnerabilities or implement authentication and authorization insufficiently, an adversary would be able to gain access to the VM/Container management and pose as a tenant. It is also possible that an adversary gains the ability to submit requests without prior authentication and authorization.

    The NFO/FOCOM interfaces encompasses a great deal of privileges because anyone gaining sufficient access is able to deploy new instances and disrupt existing O-Cloud services. It may also be possible for an adversary to submit compromised VM/Container images that unsuspecting tenants then use to initiate O-Cloud services. Moreover, adversaries can use the same access to extract business data, configuration data, user data and possibly credentials. For example, they may be able to create backups of VM/Container instances or they can export VM/Container images. The impact of compromised credentials is exacerbated by the fact that weak and insufficient safeguarding of credentials is recognized as one of the top threats in cloud computing [38].

    Container example: Adversaries may abuse a container administration service to execute commands within a container. A container administration service such as the Docker daemon, the Kubernetes API server, or the kubelet may allow remote management of containers within an environment.

    Container example: In Docker, adversaries may specify an entrypoint during container deployment that executes a script or command, or they may use a command such as docker exec to execute a command within a running container. In Kubernetes, if an adversary has sufficient permissions, they may gain remote execution in a container in the cluster via interaction with the Kubernetes API server, the kubelet, or by running a command such as kubectl exec.

    | +| Threat type | Tampering, Information disclosure, Denial of Service and Elevation of privilege | +| Impact type | Integrity, Confidentiality, Availability, Authorization | +| Affected Asset | VNF/CNF, host OS, Hypervisor/Container Engine software and related information | + +#### 7.4.2.8 Threats concerning Acceleration Abstraction Layer (AAL) + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-01 | +| Threat title | Attacker exploits insecure API to gain access to hardware accelerator resources | +| Threat description |

    Insecure AAL API allows an attacker to tamper the requests/responses sent between the AAL components, the O-Cloud platform and O-RAN APPs/VNFs/CNFs.

    For example, the attacker can tamper requests and services sent over AALI-C-Mgmt between IMS and the hardware accelerator manager, hence capability of the hardware accelerator device, fault information, logs, performance information and others are not as requested. This affects the normal operation of the O-Cloud, and even causes tampering.

    An attacker can tamper application (e.g. O-DU) requests sent over AALI-C-App to an AAL implementation for allocation of buffers. This affects the normal operation of the applications, and even causes tampering.

    An attacker can tamper application (e.g. O-DU) requests sent over AALI-P for configuring and managing the AAL-LPU(s). This affects the normal operation of the applications, and even causes tampering.

    | +| Threat type | Tampering | +| Impact type | Integrity | + +| | | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Affected Asset | Data in transit AALI-C-App & AALI-P interfaces, Data in transit vendor specific interface, AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-02 | +| Threat title | Internal Overload DoS attack targeting AAL services | +| Threat description |

    Overload situation could appear in the case of DoS attack or increased traffic on AAL interfaces. Inability to mitigate traffic volumetric attacks on AAL affects availability of AAL data and services.

    DoS attacks on the AALI-C interface affect the different services provided by the hardware accelerator manager and the transport abstraction framework.

    DoS attacks on the AALI-P interface affect the configuration and management of AAL-LPU (Acceleration Abstraction Layer Logical Processing Unit) by an application (e.g. O-DU) in addition to acceleration functionality.

    | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-03 | +| Threat title | Fail to clear resources | +| Threat description |

    Fail to clear accelerator resources after a process termination. This causes an information leakage and incorrect results for computations. Further, failure to release accelerator resources may prevent other processes from running.

    This threat is relevant to accelerator resources either inside the hardware accelerator device (internal memories, registers, cache) or in the O-Cloud memories used by accelerators.

    | +| Threat type | Information disclosure, Denial of service | +| Impact type | Confidentiality, Availability | +| Affected Asset | AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-04 | +| Threat title | HAM compromise | +| Threat description | A malicious actor can gain access to HAM to gain unauthorized access and control of the hardware accelerator device. This can result in the disruption of services (DoS) and tampering of accelerator components, such as firmware, drivers which can cause the accelerator to behave abnormally or crash altogether. | +| Threat type | Tampering, Denial of service | +| Impact type | Integrity, Availability | +| Affected Asset | Data in transit AALI-C-App & AALI-P interfaces, Data in transit vendor specific interface, AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-05 | +| Threat title | Malicious memory accesses | +| Threat description |

    AAL that allows one process running on the hardware accelerator device to access memory owned by another process running on the hardware accelerator device can leak information (impact on confidentiality).

    Similarly, AAL allowing concurrently executing processes to write to one another's memory may have correctness errors (impact on integrity).

    If multiple processes are running concurrently and one is allowed to dominate accelerator resources, the other may suffer from degraded performance. For example, if one process can evict all cache entries belonging to the other, the victim will suffer performance penalties (impact on availability).

    | +| Threat type | Information disclosure, Tampering, Denial of service | +| Impact type | Confidentiality, Integrity, Availability | +| Affected Asset | AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AAL-06 | +| Threat title | Firmware attacks | +| Threat description | Hardware accelerators often have their own firmware, which can be targeted by attackers. This could include modifying the firmware to introduce vulnerabilities (e.g., malware) or installing a malicious firmware to extract/modify sensitive information or execute unauthorized actions (e.g., control the device remotely). | +| Threat type | Information disclosure, Tampering | +| Impact type | Confidentiality, Integrity | +| Affected Asset | AAL profiles, AAL-LPUs, Stored AAL data, AAL software, Device firmware | + +#### 7.4.2.9 Threats concerning O-Cloud instance ID + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-CLOUD-ID-01 | +| Threat title | ID reuse in O-Cloud's object lifecycle | +| Threat description |

    In O-Cloud, objects such as Containers, Pods, Nodes, and Services are identified by their IDs within a given compute pool (e.g., cluster in Kubernetes). When an object is deleted, its ID becomes available for reuse. This means that a new object can be created with the same ID as a previously deleted object. If an object gets deleted but all its associated data isn't properly isolated or cleaned, the ID, if reused, could lead to unintended data associations or leaks.

    Potential consequences:

    • • Data Residue: A new object, reusing an ID, may inherit residual data or configurations from its predecessor, leading to potential misconfigurations and incorrect data associations. This can result in sensitive data exposure.
    • • Data Overwrite: Automated processes unaware of the deletion and subsequent recreation might mistakenly write or read data from the new object, thinking it's the old one.
    | + +| | | +|----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |
    • Monitoring Ambiguities: Monitoring tools might combine metrics from the old and new objects, resulting in confusing data.
    • Operational Disruptions: The new object might operate based on the residual configurations of the old object, potentially leading to system inefficiencies or failures.
    | +| Threat type | Tampering, Information disclosure | +| Impact type | Integrity, Confidentiality | +| Affected Asset | O-Cloud Provisioning information, Software components at runtime and their associated data, Security event logs | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-CLOUD-ID-02 | +| Threat title | Node redundancy in O-Cloud deployments | +| Threat description |

    Nodes in O-Cloud often represent physical or virtual machines. If a machine fails and is replaced without deleting its corresponding Node object, and the new machine is given the same ID or the hostname, O-Cloud might treat the new machine as if it were the original.

    Potential consequences:

    • Resource Mismatch: The new host might have different resources (CPU, memory, storage) than the old one, leading to scheduling issues or resource constraints.
    • Stale Data: The new node might inherit data or configurations from the old node, leading to potential security or operational risks.
    • Network Issues: Network configurations or IP address assignments might be inconsistent or conflicting.
    | +| Threat type | Spoofing, Tampering, Information disclosure, Denial of Service | +| Impact type | Authenticity, Integrity, Confidentiality, Availability | +| Affected Asset | O-Cloud Provisioning information, Software components at runtime and their associated data, Security event logs | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-O-CLOUD-ID-03 | +| Threat title | O-Cloud ID mismanagement | +| Threat description |

    IDs are crucial for uniquely identifying objects within the O-Cloud. Mismanagement occurs when these IDs are not properly assigned, tracked, or validated, leading to potential overlaps or inconsistencies.

    Potential consequences:

    • ID Collision: Due to system glitches or bugs, two distinct objects could inadvertently be allocated the same ID. Such an occurrence is termed an ID collision. This can result in operations meant for one object inadvertently affecting the other.
    • Resource Overwrite: If two objects share the same ID, updates or modifications intended for one might overwrite the data of the other, leading to data inconsistencies or loss.
    | + +| | | +|-----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| |
    • • ID-Based Permissions: Many security protocols and access controls in O-Cloud can be tied to object IDs. If an attacker can predict, guess, or manipulate the ID generation process, they might gain unauthorized access to resources.
    • • Log Merging: Monitoring tools and logging systems use IDs to track events and operations related to specific objects. If two objects share an ID, their logs might get merged, making it challenging to trace events back to their source.
    • • RBAC Anomalies: Role-Based Access Control (RBAC) regulations attached to specific object IDs could unintentionally approve or restrict access to the novel object due to misidentification.
    | +| Threat type | Spoofing, Tampering, Information Disclosure, Repudiation, Elevation of Privilege, Denial of Service | +| Impact type | Authenticity, Integrity, Non-repudiability, Confidentiality, Availability, Authorization | +| Affected Asset | O-Cloud Provisioning information, Software components at runtime and their associated data, Security event logs | + +#### 7.4.2.10 Threats concerning time synchronization + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-TS-01 | +| Threat title | Time synchronization disruption in O-Cloud | +| Threat description |

    Disruption or manipulation of the time synchronization process within the O-Cloud can lead to severe security and operational issues. An attacker may target the time synchronization mechanisms to alter time settings across O-Cloud nodes, leading to:

    • • Impersonation of time synchronization server: An attacker may impersonate a legitimate time synchronization server, tricking nodes into accepting incorrect time data. This can cause nodes to synchronize with a malicious time source, leading to widespread time discrepancies.
    • • Data integrity loss: Inconsistent timestamps can corrupt logs and audit trails within the O-Cloud, making it difficult to trace and analyze security events accurately.
    • • Operational disruption: Time-sensitive operations within the O-Cloud may be disrupted, leading to data loss and service outages.
    • • Authentication and authorization bypass: Many security mechanisms in the O-Cloud rely on accurate time. Disrupted time synchronization can undermine token expiration, certificate validity, and other time-based access controls, potentially allowing unauthorized access to O-Cloud resources.

    EXAMPLE: Time-sensitive operations such as automated backups, scheduled tasks (e.g., resource scaling, patch management), and certificate renewals.

    NOTE: This threat is linked to the operation of CronJob resources as described in clause 4.3.1.1.6 of the O-RAN specification [i.34]. Any disruption or manipulation of the time synchronization process can severely impact scheduled operations managed by CronJobs within the O-Cloud.

    | +| Threat type | Spoofing, Tampering, Denial of Service and Elevation of privilege | +| Vulnerabilities |

    Insecure time synchronization protocols

    Insufficient authentication mechanisms and access controls for the time synchronization settings

    | + +| | | +|-----------------------|--------------------------------------------------------------------| +| | Misconfiguration of time synchronization settings on O-Cloud nodes | +| Impact type | Authenticity, Integrity, Availability and Authorization | +| Affected Asset | Log and audit trails
    O-Cloud time synchronization settings | + +### 7.4.3 Threats to open source code + +Open source introduces the following threats: + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OPENSRC-01 | +| Threat title | Developers use SW components with known vulnerabilities and untrusted libraries that can be exploited by an attacker through a backdoor attack | +| Threat description |

    The O-RAN Software Community is a Linux Foundation project, supported and funded by O-RAN to lead the implementation of the O-RAN specifications in Open Source. Industry has recognized that Open Source code introduces security risks. Open Source vulnerabilities are publicly available on the National Vulnerability Database (NVD). While this is intended for developers to disclose vulnerabilities, it is also used by hackers to exploit those vulnerabilities. Vulnerabilities frequently propagate as developers re-use free open source code enabling backdoors to attacks. There have been notable vulnerabilities from downloading open source libraries and dependencies, as well as supply chain risks when downloading Open Source code from untrusted repositories.

    Some O-RAN vendors and operators may not have accurate inventories of open-source software dependencies used by their different applications, or a process to receive and manage notifications concerning discovered vulnerabilities or available patches from the community supporting the open-source.

    Some O-RAN vendors may not have a lack of consistent Supply Chain traceability and security, and a lack of coding best practices conflicts with Security-by-Design principles.

    Developers may use modules with known vulnerabilities and untrusted libraries that can be exploited by an attacker through a backdoor attack.

    Attackers can exploit a vulnerability on the open source code and infects a hypervisor, operating system, VM or container with a malware.

    | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-OPENSRC-02 | +| Threat title | A trusted developer intentionally inserts a backdoor into an open source code O-RAN component | +| Threat description |

    A trusted developer intentionally inserts a backdoor by injecting a few lines of malicious code into an open source code component to be used within the O-RAN system. A software project team picks up and uses the infected open source code and the development team's tools for vetting and testing the component do not detect the malicious code. Unknowingly they have introduced a vulnerability into their O-RAN software code.

    The vulnerability has gone undetected and the threat actor is able to compromise the software through the inserted vulnerability. The resulting effect on the O-RAN system can take a variety of forms, from being annoying to impacting system performance (DoS) to the loss of sensitive data.

    | + +### 7.4.4 Physical Threats + +| | | +|---------------------|------------------------------------------------------------------------------------------------------------| +| Threat ID | T-PHYS-01 | +| Threat title | An intruder into a site gains physical access to O-RAN components to cause damage or access sensitive data | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | Physical attacks on the O-RAN deployment that stores or processes keys, user plane data, control plane data and management data in cleartext. | +| | O-RAN physical components might be vulnerable if: | +| |
    • • Improper physical security protection of data centers, PNFs, operation areas, etc.
    • • Improper protection to power outages (power supply)
    • • Improper protection against environmental disasters
    • • Improper maintenance and monitoring of hardware parameters
    • • Hardware backdoor
    | +| | Attackers try to modify the O-RAN components settings and configurations via local access. | + +Physical access to O-RAN components thanks to unsecured management ports and consoles (such as JTAG, serial consoles or dedicated management ports), relaxed administrator credentials management, unsecured HW and SW configuration/management could allow an attacker to inject malwares and/or manipulate existing software, steal unprotected private keys, certificates, hash values, disable security features, create a performance issue by manipulation of parameters with the purpose of eavesdropping or wiretapping on various CUS & M planes, reaching the network beyond the O-RAN or with the purpose of gaining access to the O-RAN components, denial of service, intrusion and replay attacks or other type of breaches. + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-PHYS-02 | +| Threat title | An intruder into the exchange over the Fronthaul cable network attempts to gain electronic access to cause damage or access sensitive data | +| Threat description | O-RU and O-DU may be located at different premises and connected through a cable network to support the fronthaul link. Attackers can gain access to, or control over, data traffic through breaching terminals in the cable landing sites (O-RU or O-DU). | + +### 7.4.5 Threats against 5G radio networks + +Threats against 5G radio networks include: + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-RADIO-01 | +| Threat title | Disruption through radio Jamming, Sniffing and Spoofing | +| Threat description | Like for any wireless technology, disruption through radio jamming is possible by analyzing the physical downlink and uplink control channels and signals. 5G radio network is vulnerable to: | +| |
    • • Jamming Vulnerability of Reference Signals
    • • Jamming Vulnerability of Synchronization Signal
    • • Jamming Vulnerability of the PBCH
    • • Sniffing and Spoofing Vulnerability of the PBCH
    • • Jamming Vulnerability of PDCCH
    • • Jamming Vulnerability of Physical Uplink Control Channel
    • • Jamming Vulnerability of Physical Random-Access Channel
    | +| | NOTE 1: The O-RAN OEMs need to develop new intelligence that can proactively alert the operator when this attack is initiated so that the operator can take appropriate actions to mitigate. | +| | NOTE 2: In the scenario of RF spoofing, the UE needs to be able to validate the legitimacy of the O-RU as being one owned and operated by the operator. 3GPP has proposed in a study to use Digital Signatures to mitigate this threat but there has been no agreement on this to date. The O-RAN OEMs need to develop new | + +intelligence that can proactively alert the operator when this attack is initiated so that the operator can take appropriate actions to mitigate. + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-RADIO-02 | +| Threat title | DoS attacks on cognitive radio networks [i.17] | +| Threat description | Cognitive radio (CR) technology, which is designed to enhance spectrum utilization, depends on the success of opportunistic access, where unlicensed secondary users (SUs) exploit spectrum void unoccupied by primary users (PUs) for transmissions. To realize DoS attacks, malicious users (MUs) target the critical functionalities for CR ecosystems, including spectrum sensing, agile radio, and light-handed regulation since once these functionalities fail, SUs are not able to communicate effectively. For example, MUs can directly jam the victim by injecting interference or deceive SUs into believing that there is a PU by emulating the signal characteristics of the PU, thereby evacuating the occupied spectrum. Moreover, the liability rule is vulnerable to the selfish and greedy users aiming to maximize their own private benefits. Since complying with the rule results in less transmission opportunities, such SUs may not want to invest efforts to follow the rule and thus will transmit simultaneously with PUs. | + +### 7.4.6 Threats against AI/ML system + +#### 7.4.6.1 Introduction + +This section provides the relevant threats against the AI/ML system implemented in O-RAN architecture. + +#### 7.4.6.2 Input Manipulation Attacks + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-IM-1 | +| Threat title | Training Data Control | +| Threat description | An adversary takes control of a subset of the training data by inserting or modifying training samples. | +| Threat type | Tampering | +| Vulnerabilities | Vulnerabilities in data sources, vulnerabilities in training database | +| Impact type | Integrity | +| Affected Assets | Training or test data: data sets collected externally or internally from the Near-RT RIC, O-CU and O-DU and passed to the ML training hosts in a ML system. [ASSET-D-25]
    The trained ML model [ASSET-D-26],
    The ML prediction results built into the model [ASSET-D-27],
    The behaviour of the ML system [ASSET-D-28]. | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-IM-2 | +| Threat title | Testing Data Control | +| Threat description | An adversary adds perturbations to testing samples at model deployment time to generate adversarial examples or in backdoor poisoning attacks | +| Threat type | Tampering | +| Vulnerabilities | Vulnerabilities in data sources, vulnerabilities in training database | +| Impact type | Integrity | +| Affected Assets | Training or test data: data sets collected externally or internally from the Near-RT RIC, O-CU and O-DU and passed to the ML training hosts in a ML system. [ASSET-D-25]
    The trained ML model [ASSET-D-26],
    The ML prediction results built into the model [ASSET-D-27],
    The behaviour of the ML system [ASSET-D-28]. | + +| | | +|---------------------------|-----------------------------------------------------------------------| +| Threat ID | T-AIML-IM-3 | +| Threat title | Label Manipulation | +| Threat description | An adversary may intentionally mis-assign labels to training data. | +| Threat type | Tampering | +| Vulnerabilities | Vulnerabilities in data sources, vulnerabilities in training database | +| Impact type | Integrity | + +| | | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Affected Assets | Training or test data: data sets collected externally or internally from the Near-RT RIC, O-CU and O-DU and passed to the ML training hosts in a ML system. [ASSET-D-25]
    The trained ML model [ASSET-D-26],
    The ML prediction results built into the model [ASSET-D-27],
    The behaviour of the ML system [ASSET-D-28]. | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-IM-4 | +| Threat title | AI/ML Query Exploitation | +| Threat description | An adversary may submit queries to the model and receive predictions (either labels or model confidences) and confidential data. | +| Threat type | Information Disclosure | +| Vulnerabilities | Vulnerabilities in data sources, vulnerabilities in training database, vulnerabilities in AI/ML APIs | +| Impact type | Confidentiality | +| Affected Assets | The trained ML model [ASSET-D-26],
    The ML prediction results built into the model [ASSET-D-27],
    The behaviour of the ML system [ASSET-D-28]. | + +#### 7.4.6.3 Data poisoning attacks + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-DP-01 | +| Threat title | Black-box Data Poisoning | +| Threat description | An attacker in possession of a compromised data-source can inject poisoned data which can be consumed by AI/ML for training. For such an attack, the attacker does not need to know any details of the AI/ML algorithm, or the parameters being used. Knowledge of inputs and outputs of AI/ML is sufficient to launch such attacks. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-DP-02 | +| Threat title | Grey-box Data Poisoning | +| Threat description | An attacker being able to query the database which stores the training data, and/or streaming data used for online ML models, and/or AI/ML models may be able to get more details about the AI/ML algorithms being used and parameters configured if any. This can help the attacker to launch an attack which can poison the training data in a manner that would affect that particular algorithm or its parameters the most. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW, O1 interface for streaming data, A1 interface, E2 interface for streaming data | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-DP-03 | +| Threat title | White-box Data Poisoning | +| Threat description | An attacker having full knowledge of the AI/ML algorithm being used, the configurable parameters like thresholds, hyper-parameters, etc. can launch a data poisoning attack in a manner which can modify the behaviour of AI/ML algorithm with slow poisoning and can make it very challenging to detect such attacks. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW, O1 interface for streaming data, A1 interface, E2 interface for streaming data | + +#### 7.4.6.4 Membership Inference Attacks + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MEI-01 | +| Threat title | Information Access – Membership Inference | +| Threat description | An attacker possesses different levels of information on the model architecture, training parameters, training data, and relation between the output to the input. Based on the level of information access, the membership information attack (MIA) can be Black-box MIA, or Gray-box MIA or White-box MIA. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Assets | The trained ML model which includes the configured hyperparameters, inference algorithm, and learned parameters. Near-RT RIC software, Non-RT RIC software. | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MEI-02 | +| Threat title | Inference Technique – Membership Inference | +| Threat description | An attacker by applying different analysis methods tries to infer input to output relation. Some of the attack types are Decision threshold analysis, Gradient-based analysis, Distance-based analysis. In Decision threshold analysis, the subtle changes in input's relation to the model's output confidence score is observed. In Gradient-based analysis techniques such as back propagation is used to analyse input to output variation. In Distance-based analysis the distance between model's output for different inputs in multi-dimensional space is used. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Assets | The trained ML model which includes the configured hyperparameters, inference algorithm, and learned parameters. Near-RT RIC software, Non-RT RIC software. | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MEI-03 | +| Threat title | Target based – Membership Inference | +| Threat description | In a target-based membership attack the attacker would like to understand whether specific individual data or data of a group of individuals are involved in the training set. The attack types are known as Individual membership inference attack, Group membership inference attack, respectively. In Individual membership inference attack, the attacker tries to determine if a specific user information is included in the training data. In Group membership inference attack, the attacker tries to determine behaviour of individuals and group them based on available data. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Assets | The trained ML model which includes the configured hyperparameters, inference algorithm, and learned parameters. Near-RT RIC software, Non-RT RIC software. | + +#### 7.4.6.5 Model Stealing + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-ME-01 | +| Threat title | Intellectual Property Theft | +| Threat description | Stolen models can lead to the theft of intellectual property, allowing attackers to replicate the model's functionality without incurring the associated development costs. If a competitor gains unauthorized access to a trained model, it can undermine the original developer's competitive advantage by using the model for similar or competing purposes. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-ME-02 | +| Threat title | Data Privacy Violations | +| Threat description | The stolen model may contain sensitive information embedded within its learned parameters. This can result in privacy breaches, especially if the model was trained on sensitive or personal data. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-ME-03 | +| Threat title | Adversarial Attacks with Stolen Models | +| Threat description | Attackers may exploit the extracted model to craft adversarial examples (to mount an evasion attack) or launch targeted attacks against the system that initially deployed the model, using obtained knowledge about possible vulnerabilities. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Assets | Database holding data from xApp applications and E2 Node [ASSET-D-10],
    Training or test data sets collected externally or internally [ASSET-D-25],
    Trained ML model [ASSET-D-26],
    Near-RT-RIC SW [ASSET-C-02],
    Non-RT-RIC SW [ASSET-C-11] | + +#### 7.4.6.6 Model Inversion Threats + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MOI-01 | +| Threat title | Black-box Model Inversion | +| Threat description | An attacker has access to the model's input-output pairs allowing them to input data and receive predictions. The attacker generates inputs, analyzes the model's outputs, and iteratively refines the inputs based on the obtained information. This process continues until the attacker is able to approximate the original training data. The attacker has no knowledge of the model's architecture, parameters, or the training data. | +| Threat type | Information Disclosure | +| Vulnerabilities | Model is overfitted, model may have memorized specific training examples, model API not properly protected | +| Impact type | Disclosure of sensitive/proprietary data | +| Affected Assets | Database holding data from xApp applications and E2 Node [ASSET-D-10],
    Training or test data sets collected externally or internally [ASSET-D-25],
    Trained ML model [ASSET-D-26]
    The ML prediction results built into the model [ASSET-D-27]
    The behavior of the ML system including tasks for data collection, data wrangling, pipeline management, model retraining, and model deployment. [ASSET-D-28] | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MOI-02 | +| Threat title | White-box Model Inversion | +| Threat description | An attacker has access to the AI model, including its architecture, parameters (such as weights and biases), and possibly partial knowledge of the training data. This information allows the attacker to exploit the inner workings of the model more effectively and reconstruct the original training data with higher accuracy. In this scenario, the attacker can use gradient-based optimization techniques to maximize the model's confidence in the target label or class, ultimately converging to a close approximation of the target data point. | +| Threat type | Information Disclosure | +| Vulnerabilities | Model is not protected, training data is not protected, model is overfitted, model may have memorized specific training examples, model API not protected | +| Impact type | Disclosure of sensitive/proprietary data | +| Affected Assets | Database holding data from xApp applications and E2 Node [ASSET-D-10],
    Training or test data sets collected externally or internally [ASSET-D-25],
    Trained ML model [ASSET-D-26]
    The ML prediction results built into the model [ASSET-D-27]
    The behavior of the ML system including tasks for data collection, data wrangling, pipeline management, model retraining, and model deployment. [ASSET-D-28] | + +#### 7.4.6.7 AI Supply Chain Attacks + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-SC-01 | +| Threat title | Poisoning via Supply Chain | +| Threat description | Adversaries may corrupt or manipulate training datasets to cause the AI model to learn incorrect associations or make biased predictions. This can lead to degraded performance, wrong decisions, or even backdoors in the final system. | +| Threat type | Tampering, Denial of Service | + +| | | +|------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Impact type | Integrity, Availability | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps),Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-SC-02 | +| Threat title | Model Tampering | +| Threat description | Attackers might inject malicious code or logic into the AI model itself during training or deployment. This could allow them to gain control over the target system, steal sensitive data, or force the AI system to produce incorrect results on demand. | +| Threat type | Tampering, Information disclosure | +| Impact type | Integrity, Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps),Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-SC-03 | +| Threat title | Backdoor via Supply Chain | +| Threat description | In these attacks, a seemingly benign AI model is infected with malicious code that remains dormant until it receives a specific trigger. At this point, the attacker can remotely activate the backdoor and use it to compromise the target system or exfiltrate data. | +| Threat type | Tampering, Information disclosure | +| Impact type | Integrity, Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps),Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-SC-04 | +| Threat title | Hardware Tampering | +| Threat description | Malicious actors may also focus on manipulating the hardware used for AI processing, such as GPUs, ASICs, or FPGAs. By introducing backdoors or vulnerabilities in these components, attackers can compromise the confidentiality, integrity, and availability of AI systems even if the software and data are secure. | +| Threat type | Tampering, Information disclosure | +| Impact type | Integrity, Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node, Trained ML model, ML components deploying machine learning (xApps, rApps),Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-SC-05 | +| Threat title | Insecure Maintenance APIs | +| Threat description | Many AI services are exposed through APIs, for example for deployment and maintenance, that can be abused by attackers to launch supply chain attacks. If these APIs are not properly secured, they can be used to inject malicious code or exfiltrate sensitive information from the target system. | +| Threat type | Tampering, Information disclosure | +| Impact type | Integrity, Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps),Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|---------------------|----------------------------------------| +| Threat ID | T-AIML-SC-06 | +| Threat title | Third-party Libraries and Dependencies | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | AI systems often rely on third-party libraries and open-source components which might contain vulnerabilities or backdoors that attackers can exploit. Insecure software supply chains increase the risk of such attacks. | +| Threat type | Tampering, Information disclosure | +| Impact type | Integrity, Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | + +#### 7.4.6.8 Output Integrity Attack + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-OI-01 | +| Threat title | Denial of Service Impacting Output Integrity | +| Threat description | The AI/ML output can be manipulated to contain values that are incorrect or out of range. This can lead to service degradation, partial failure or total failure of the O-RAN element that is consuming this output and lead to denial of service to other O-RAN elements or subscribers. | +| Threat type | Denial of service | +| Impact type | Availability | +| Affected Assets | Training or test data sets collected externally or internally, Trained ML model, ML prediction results, A1 policies, E2 node data, Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-OI-02 | +| Threat title | Subscriber QoE Change | +| Threat description | The AI/ML output can be manipulated to contain values which can influence the configuration or policies being used by the O-RAN elements. This can lead to a behavior of O-RAN network elements where a subscriber or a group of subscribers is treated unfairly or with a preference. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Assets | Training or test data sets collected externally or internally, Trained ML model , ML prediction results ,Data transported over the O1 interface,A1 policies, E2 node data,Near-RT-RIC SW, Non-RT-RIC SW . | + +#### 7.4.6.9 Model Poisoning + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MP-01 | +| Threat title | Model Parameter Poisoning | +| Threat description | The adversary has access to the parameters file of a trained model. The parameters file is altered to change the model's predictions to achieve the goals of the adversary. | +| Threat type | Tampering | +| Vulnerabilities |
    • Insufficient access controls to the model's parameters [i.33]
    • Inadequate monitoring and logging of model's activity [i.32]
    • Lack of control for poisoning in model [i.32]
    • Weak access protection mechanisms for ML model components [i.32]
    | +| Impact type | Integrity | +| Affected Assets | [ASSET-D-26] Trained ML model.
    [ASSET-C-12] ML components deploying machine learning (xApps, rApps).
    [ASSET-D-27] The ML prediction results built into the model (e.g. expected outcomes). | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MP-02 | +| Threat title | Inference Algorithm Poisoning | +| Threat description | The adversary has access to the code of a trained model. The inference algorithm is altered to change the model's predictions to achieve the goals of the adversary. | +| Threat type | Tampering | +| Vulnerabilities |
    • Insufficient access controls to the model's code [i.33]
    • Inadequate monitoring and logging of model's activity [i.32]
    • Lack of code integrity checking
    • Weak access protection mechanisms for ML model components [i.32]
    | +| Impact type | Integrity | +| Affected Assets | [ASSET-D-26] Trained ML model.
    [ASSET-D-27] The ML prediction results built into the model (e.g. expected outcomes). | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MP-03 | +| Threat title | Learning Algorithm Poisoning | +| Threat description | The adversary has access to the code of an untrained model. The learning algorithm is altered to cause the model to make incorrect predictions. | +| Threat type | Tampering | +| Vulnerabilities |
    • Insufficient access controls to the model's code [i.33]
    • Inadequate monitoring and logging of model's activity [i.32]
    • Weak access protection mechanisms for ML model components [i.32]
    • Lack of code integrity checking
    | +| Impact type | Integrity | +| Affected Assets | [ASSET-C-12] ML components deploying machine learning (xApps, rApps). | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MP-04 | +| Threat title | Model Control | +| Threat description | An adversary takes control of the model parameters by either generating a Trojan trigger and inserting it in the model or by sending malicious local model updates in federated learning | +| Threat type | Tampering | +| Vulnerabilities | Vulnerabilities in ML model storage, vulnerabilities in ML model transfer | +| Impact type | Integrity | +| Affected Assets | ML components deploying machine learning [ASSET-C-12]
    The trained ML model [ASSET-D-26],
    The ML prediction results built into the model [ASSET-D-27],
    The behavior of the ML system [ASSET-D-28]. | + +#### 7.4.6.10 Model Skewing Attacks + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MS-01 | +| Threat title | Data Manipulation for Model Skewing | +| Threat description | The attacker manipulates the data involved in the training of the model. The attacker modifies/injects the training data with modified data, or modifies the labels associated with the training data, resulting in learnt model behaviour to be changed. The impacted models have reduced accuracy / biased trained models, thereby the ability to make correct predications is compromised, or the output is biased. The model skewing attacks can significantly impact the operation of networks causing service disruptions, reputational damage, and financial losses. | +| Threat type | Tampering, (Applicable Threats T-SMO-11, T-SMO-12, T-SMO-31, t_rApps_05) | +| Impact type | Integrity, and use-case specific impacts on O-RAN network. | +| Affected Assets | Trained ML model, ML Prediction Results, ML system | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-MS-02 | +| Threat title | Feedback Manipulation for Model Skewing | +| Threat description | The attacker manipulates the feedback mechanisms used by the AI/ML for continuous improvement during deployment. The attack can significantly impact the operation of networks causing service disruptions, reputational damage, and financial losses. | +| Threat type | Tampering, (Applicable Threats T-SMO-11, T-SMO-12, T-SMO-31, t_rApps_05) | + +| | | +|-----------------|------------------------------------------------------------| +| Impact type | Integrity, and use-case specific impacts on O-RAN network. | +| Affected Assets | Trained ML model, ML Prediction Results, ML system | + +#### 7.4.6.11 Transfer Learning Attack + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-TL-01 | +| Threat title | Data Poisoning for Transfer Learning | +| Threat description | Attackers can poison the source model's training data by injecting malicious samples, which get propagated into the target model during transfer learning, causing misclassification or unintended behaviour in the latter. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-TL-02 | +| Threat title | Model Stealing for Transfer Learning | +| Threat description | By using a series of carefully crafted queries to the source model, attackers can extract sensitive information about its architecture and parameters, which they can then use to build a similar model for malicious purposes. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-TL-03 | +| Threat title | Adversarial Examples | +| Threat description | Attackers can create input samples that fool both the source and target models, even if these inputs are visually or semantically similar to benign ones. These adversarial examples can be used to bypass security systems or cause misclassifications in critical applications like self-driving cars or healthcare. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, Near-RT-RIC SW, Non-RT-RIC SW | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-TL-04 | +| Threat title | Backdoor for Transfer Learning | +| Threat description | Attackers can embed hidden malicious functionality into the source model, which remains dormant until triggered by specific input patterns. When the trojans are transferred to the target model, they can cause unexpected behaviour or leak sensitive information. | +| Threat type | Tampering, Information disclosure | +| Impact type | Authenticity, Integrity, Availability, Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | + +#### 7.4.6.12 AI Energy-Latency Attack + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-EL-01 | +| Threat title | Model Extraction | +| Threat description | By monitoring the energy and latency patterns, an attacker might deduce the structure of the neural network, including the types of layers, their sequence, and possibly hyperparameters. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node [ASSET-D-10],
    Trained ML model [ASSET-D-26],
    Near-RT-RIC SW [ASSET-C-02],
    Non-RT-RIC SW [ASSET-C-11],
    AAL software [ASSET-C-29],
    Hardware accelerator device firmware [ASSET-C-30] | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-EL-02 | +| Threat title | Data Inference | +| Threat description | Observing the energy and latency signatures of different computations could allow an attacker to make inferences about the input data, potentially leading to privacy breaches, especially if the data is sensitive. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Assets | Database holding data from xApp applications and E2 Node [ASSET-D-10],
    Near-RT-RIC SW [ASSET-C-02],
    Non-RT-RIC SW [ASSET-C-11],
    AAL software [ASSET-C-29],
    Hardware accelerator device firmware [ASSET-C-30] | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-EL-03 | +| Threat title | Denial of Service via Side Channels | +| Threat description | An attacker could exploit these side channels to craft inputs that maximize energy consumption or computation time, leading to a denial of service by overloading the system or draining battery life. | +| Threat type | Denial of service | +| Vulnerabilities | Vulnerabilities in data sources | +| Impact type | Availability | +| Affected Assets | Database holding data from xApp applications and E2 Node [ASSET-D-10],
    Trained ML model [ASSET-D-26],
    Near-RT-RIC SW [ASSET-C-02],
    Non-RT-RIC SW [ASSET-C-11],
    AAL software [ASSET-C-29],
    Hardware accelerator device firmware [ASSET-C-30] | + +#### 7.4.6.13 Evasion attack + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-AIML-EV-01 | +| Threat title | Grey-box based Data Evasion | +| Threat description | Possibility to tamper with the input to AI ML application during the inference phase in the Near-RT RIC or Non-RT RIC (model, model parameters, etc.) for example the model's gradient | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Assets | Database holding data from xApp applications and E2 Node,
    Training or test data sets collected externally or internally,
    Trained ML model,
    Near-RT-RIC SW,
    Non-RT-RIC SW | + +### 7.4.7 Protocol Stack Threats + +The A1 and R1 interfaces use the REST protocol stack shown in the figure below. The transport network layer is built on IP transport. TCP provides the communication service at the transport layer. HTTP is the application-level protocol used providing reliable transport of messages. TLS provides secure HTTP connections for secure transport of messages. The application layer protocol is based on a RESTful approach with transfer of JSON formatted policy statements. Each of these protocols has known vulnerabilities that can be exploited by a malicious actor. + +| | | +|------------------|------| +| Data Interchange | JSON | +| Application | HTTP | +| Security | TLS | +| Transport Layer | TCP | +| Network layer | IP | +| Data Link Layer | L2 | +| Physical Layer | L1 | + +**Figure 7-13 : REST Protocol Stack for the A1 and R1 Interfaces** + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ProtocolStack-01 | +| Threat title | REST API Exploits | +| Threat description | REST API common attacks include injection, cross site scripting, and DoS attacks that can exploit common vulnerabilities if proper controls are not used to protect against vulnerabilities. | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------| +| Threat ID | T-ProtocolStack-02 | +| Threat title | REST API – Broken Object Level Authorization | +| Threat description | The REST API can be exploited to expose object identifiers without proper authorization checks. | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ProtocolStack-03 | +| Threat title | JSON Exploits | +| Threat description | JSON attacks include injection, deserialization, web token, and cross site scripting attacks that can exploit common vulnerabilities if proper controls are not used to protect against vulnerabilities. | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-ProtocolStack-04 | +| Threat title | HTTP Exploits | +| Threat description | DDoS attacks include HTTP GET Flood, Garbage Flood, and Reverse Bandwidth Floods. Other well known HTTP attacks include injection attacks, such as Cross-Site Scripting (XSS) and SQL injection. | + +| | | +|------------------|---------------------------| +| Threat ID | T-ProtocolStack-05 | +|------------------|---------------------------| + +| | | +|--------------------|-------------------------------------------------------------------| +| Threat title | TCP Volumetric DDoS | +| Threat description | TCP DDoS attacks include TCP SYN Flood, ACK Flood, and RST Flood. | + +### 7.4.8 SMO Threats + +#### 7.4.8.1 General SMO Threats + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-01 | +| Threat title | External attacker exploits authentication weakness on SMO | +| Threat description | An external attacker can exploit the improper/missing authentication weakness on SMO functions. If the authentication of O-RAN subjects on A1, O1, O2, and External interfaces on SMO is not supported or not properly implemented, those interfaces without proper credentials could be exploited to gain access to the SMO. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-02 | +| Threat title | External attacker exploits authorization weakness on SMO | +| Threat description | An external attacker can exploit the improper/missing authorization weakness on SMO functions. A malicious external entity on A1, O1, O2, and External interfaces without authorization or with an incorrect access token may invoke the SMO functions. The data at rest related to that function will be leaked to the attacker. In addition, an attacker can be able to perform certain actions, e.g. disclose O-RAN sensitive information or alter O-RAN components. | +| Threat type | Elevation of Privilege, Information Disclosure | +| Impact type | Authorization. Confidentiality | +| Affected Asset | SMO | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-03 | +| Threat title | External Overload DoS attack targeted at SMO | +| Threat description | Overload situation could appear in the case of DoS attack or increased traffic on externally facing interfaces. Inability to mitigate traffic volumetric attacks on an external interface affects availability of SMO data and functions. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | SMO | + +| | | +|--------------|----------------------------------------------------------------------| +| Threat ID | T-SMO-04 | +| Threat title | Internal attacker exploits authentication weakness on a SMO function | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | An internal attacker can exploit the improper/missing authentication weakness on SMO functions. If the authentication of internal interfaces (e.g. Internal Message Bus and R1) on SMO is not supported or not properly implemented, those interfaces without credentials could be exploited to gain access to the SMO. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-05 | +| Threat title | Internal attacker exploits authorization weakness on a SMO function | +| Threat description | An internal attacker can exploit the improper/missing authorization weakness on SMO functions. Malicious internal entities without authorization or with an incorrect access token may invoke the SMO functions. The data at rest related to these functions will be leaked to the attacker. In addition, an attacker can be able to perform certain actions, e.g. disclose O-RAN sensitive information or alter O-RAN components. | +| Threat type | Elevation of Privilege, Information Disclosure | +| Impact type | Authorization | +| Affected Asset | SMO | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-06 | +| Threat title | Internal Overload DoS attack targeted at SMO functions | +| Threat description | Overload situation could appear in the case of DoS attack or increased traffic on internal SMO interfaces. Inability to mitigate traffic volumetric attacks on an external interface affects availability of SMO data and functions. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | SMO | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-07 | +| Threat title | Internal DoS attack disables internal SMO function(s) or process(es) | +| Threat description | Internal malicious actor exploits a vulnerability or escalates privilege to execute a DoS attack by disabling one or more SMO processes or functions. Inability to detect and report such events affects availability of SMO functions. | +| Threat type | Denial of Service, Escalation of Privilege | +| Impact type | Availability | +| Affected Asset | SMO | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-08 | +| Threat title | Attacker exploits insecure API to gain access to SMO | +| Threat description | An insecure API may allow access to a system for an attacker to conduct remote code execution or an advanced persistent threat | + +| | | +|----------------|------------------------------------------------------------| +| Threat type | Tampering, Information Disclosure, Escalation of Privilege | +| Impact type | Integrity, Confidentiality, Authorization | +| Affected Asset | SMO | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-09 | +| Threat title | Sensitive data in transit is exposed to an internal attacker | +| Threat description | Unprotected data transferred between internal SMO functions is disclosed to an internal threat actor | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | SMO | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-10 | +| Threat title | Sensitive data at rest is exposed to an internal attacker | +| Threat description | Unprotected data stored on the SMO is disclosed to an internal threat actor that has gain authorized access through privilege escalation | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | SMO | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-11 | +| Threat title | AI/ML poisoning by internal attacker | +| Threat description | Internal attacker gains authorized access exploited to poison AI/ML training data, or the AI/ML models, stored in the SMO to influence insights. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | SMO | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-12 | +| Threat title | AI/ML exposure on external entity | +| Threat description | An external attacker can gain access to external entities to view or modify sensitive data AI/ML data, or models, transferred between the external function and SMO via external interfaces(e.g., EI, Human-Machine, A1, O1) | +| Threat type | Information disclosure, Tampering | +| Impact type | Confidentiality, Integrity | +| Affected Asset | SMO | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-13 | +| Threat title | Malicious actor views local logs | +| Threat description | Malicious actor accesses locally stored logs in the SMO to perform reconnaissance to collect sensitive or private information. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | SMO | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-14 | +| Threat title | Malicious actor modifies local log entries | +| Threat description | Malicious actor accesses locally stored logs in the SMO to modify entries to hide presence or cause confusion. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | SMO | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-15 | +| Threat title | Malicious actor deletes local log entries | +| Threat description | Malicious actor accesses locally stored logs in the SMO to delete entries to hide presence or cause confusion. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | SMO | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-16 | +| Threat title | Malicious actor intercepts exports of local logs | +| Threat description | Malicious actor gains access to an external interface to intercept data in transit as logs are transferred from the SMO to a remote server/external entity. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | SMO | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-17 | +| Threat title | Malicious external actor gains unauthorized access to logs | +| Threat description | Malicious external actor gains unauthorized access to stored logs to view, modify, and delete | +| Threat type | Elevation of Privilege | + +| | | +|----------------|-----------------| +| Impact type | Confidentiality | +| Affected Asset | SMO | + +| | | +|--------------------|----------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-18 | +| Threat title | Malicious internal actor gains authorized access to logs | +| Threat description | Malicious internal actor gains authorized access to stored logs to view, modify, and delete. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | SMO | + +#### 7.4.8.2 SMO Threats at O2 interface + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-19 | +| Threat title | Internal attacker exploits O2 interface to view data in transit between SMO and O-Cloud | +| Threat description | If the O2 interface is not properly confidentiality protected, an internal attacker can perform a man-in-the-middle attack to view data in transit. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | O2 interface | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-20 | +| Threat title | Internal attacker exploits O2 interface to modify data in transit between SMO and O-Cloud | +| Threat description | If the O2 interface is not properly integrity protected, an internal attacker can perform a man-in-the-middle attack to modify data in transit. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | O2 interface | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-21 | +| Threat title | Internal attacker uses O2 interface via SMO to exploit API vulnerability to gain access to O-Cloud infrastructure | +| Threat description | If the O2 interface uses an API with a known vulnerability that is not properly protected or patched, an attacker can exploit it to gain access to the O-Cloud infrastructure from the SMO. | +| Threat type | Spoofing | +| Impact type | Authenticity | + +| | | +|----------------|---------| +| Affected Asset | O-Cloud | +|----------------|---------| + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-22 | +| Threat title | Internal attacker floods O2 interface via SMO to cause DDoS on O-Cloud infrastructure | +| Threat description | If the O2 interface is not protected, an internal attacker on the SMO can flood the O2 interface to overload the O-Cloud. This can prevent legitimate messages from reaching the O-Cloud or cause heavy processing at the O-Cloud, resulting in performance degradation. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | O-Cloud | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-23 | +| Threat title | External attacker uses O2 interface via O-Cloud to exploit API vulnerability to gain access to SMO | +| Threat description | If the O2 interface uses an API with a known vulnerability that is not properly protected or patched, an attacker can exploit it to gain access to the SMO from the O-Cloud infrastructure. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-24 | +| Threat title | External attacker floods O2 interface via O-Cloud to cause DDoS on SMO | +| Threat description | If the O2 interface is not protected, an external attacker in the O-Cloud can flood the O2 interface to overload the SMO. This can prevent legitimate messages from reaching the SMO or cause heavy processing at the SMO, resulting in performance degradation or outage of the SMO. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | SMO | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-25 | +| Threat title | External attacker uses O2 interface via O-Cloud to gain authorized access to sensitive data-at-rest at the SMO | +| Threat description | If the SMO is not protected, an external attacker at the O-Cloud can use the O2 interface to gain authorized access to the SMO to view data-at-rest. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | SMO | + +#### 7.4.8.3 SMO Threats at External interfaces + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-26 | +| Threat title | External attacker exploits External interface to view data in transit between SMO and external service | +| Threat description | If an External interface is not properly confidentiality protected, an external attacker can perform a man-in-the-middle attack to view data in transit. | +| Threat type | Information disclosure | +| Impact type | Confidentiality | +| Affected Asset | External interface | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-27 | +| Threat title | External attacker exploits External interface to modify data in transit between SMO and external service | +| Threat description | If an External interface is not properly integrity protected, an external attacker can perform a man-in-the-middle attack to modify data in transit. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | External interface | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-28 | +| Threat title | External attacker uses External interface to exploit API vulnerability to gain access to SMO | +| Threat description | If an External interface uses an API with a known vulnerability that is not properly protected or patched, an attacker can exploit it to gain access to the SMO. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-29 | +| Threat title | External attacker floods External interface to cause DDoS at SMO | +| Threat description | If the External interface is not protected, an external attacker can flood an External interface to overload the SMO. This can prevent legitimate messages and data from reaching the SMO or cause heavy processing at the SMO, resulting in performance degradation or outage of the SMO. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | SMO | + +| | | +|---------------------|-----------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-30 | +| Threat title | External attacker uses External interface to gain access to sensitive data-at-rest at the SMO | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | If the SMO is not protected, an external attacker can use the External interface to gain authorized access to the SMO to view data-at-rest. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | SMO | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-31 | +| Threat title | External attacker poisons External AI/ML data to corrupt SMO | +| Threat description | External data sources may be outside the control of the stakeholder(s) responsible for the O-RAN deployment. The stakeholder for an External data source could fail to provide proper security controls to protect data consumed by the SMO. If an external attacker were to gain access to AI/ML data, it could be corrupted and then be used at the SMO. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | SMO | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SMO-32 | +| Threat title | External attacker poisons External Enrichment Information data sources to corrupt SMO | +| Threat description | External data sources may be outside the control of the stakeholder(s) responsible for the O-RAN deployment. The stakeholder for an External data source could fail to provide proper security controls to protect data consumed by the SMO. If an external attacker were to gain access to External Enrichment Information, it could be corrupted and then be used at the SMO. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | SMO | + +### 7.4.9 Threats against Shared O-RU + +Threat Analysis tables are provided for each of the identified Shared O-RU threats in the clauses below. The Shared O-RU Threats are classified into 6 threat groups: + +- Lateral Movement Between Network Functions +- Physical Port Access Threats +- Data Access Threats +- Availability Threats +- Configuration Threats +- Resiliency Threats + +Use of the term “MNO Tenant” or “Tenant” refers to a “Shared Resource Operator (SRO)” as defined in [i.27]. + +#### 7.4.9.1 Lateral Movement Between Network Functions + +This clause provides threat analysis tables for threats to access between Shared O-RU network functions. + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-01 | +| Threat title | O-DU Tenant accesses O-DU Host | +| Threat description | The O-DU Tenant accesses the O-DU Host through the Shared O-RU. Weak authentication can be exploited by a tenant to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Host | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-02 | +| Threat title | O-DU Host accesses O-DU Tenant | +| Threat description | The O-DU Host accesses the O-DU Tenant through the Shared O-RU. Weak authentication can be exploited by a host to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Tenant | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-03 | +| Threat title | O-DU Tenant accesses O-DU Tenant | +| Threat description | An O-DU Tenant accesses another O-DU Tenant through the Shared O-RU supporting multiple tenants. Weak authentication can be exploited by a tenant to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Tenant | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-04 | +| Threat title | Password Attack on OFH M-Plane | +| Threat description | Use of single-factor authentication with password on the Open Fronthaul M-Plane can be exploited by an internal malicious actor to gain access to the Shared O-RU. The attack can be a brute-force attack or stolen password. There is increased risk of password attack in a multi-tenant environment. The internal malicious actor may be the Host MNO, a Tenant MNO, or a 3rd-party. [i.9] | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | Shared O-RU, O-DU Host, O-DU Tenant | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-05 | +| Threat title | Untrusted peering to O-DU | +| Threat description | Attacker exploits weak authentication on the O-DU to establish a session with a malicious app masquerading as a Shared O-RU. From the O-DU, a malicious actor can move laterally across Shared O-RUs and northbound to the O-CU and SMO. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Host, O-DU Tenant | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-06 | +| Threat title | Untrusted peering to the Shared O-RU | +| Threat description | Attacker exploits weak authentication on the Shared O-RU to establish session with a malicious app masquerading as a O-DU Host or O-DU Tenant | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-07 | +| Threat title | Untrusted peering to the SMO | +| Threat description | Attacker exploits weak authentication on the SMO to establish session with a malicious app masquerading as a Shared O-RU. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO Host, SMO Tenant | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-08 | +| Threat title | SMO Tenant accesses SMO Host | +| Threat description | The SMO Tenant accesses the SMO Host through the Shared O-RU. Weak authentication can be exploited by a tenant to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO Host | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-09 | +| Threat title | SMO Host accesses SMO Tenant | +| Threat description | The SMO Host accesses the SMO Tenant through the Shared O-RU. Weak authentication can be exploited by a host to move laterally across the deployment. | + +| | | +|----------------|--------------| +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO Tenant | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-10 | +| Threat title | O-DU Host accesses O-CU Tenant | +| Threat description | The O-DU Host accesses the O-CU Tenant through the Shared O-RU. Weak authentication can be exploited by a host to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Tenant | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-11 | +| Threat title | O-DU Tenant accesses O-CU Host | +| Threat description | The O-DU Tenant accesses the O-CU Host through the Shared O-RU. Weak authentication can be exploited by a host to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Host | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-12 | +| Threat title | O-DU Tenant accesses O-CU Tenant | +| Threat description | The O-DU Tenant accesses another O-CU Tenant through the Shared O-RU supporting multiple tenants. Weak authentication can be exploited by a host to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Tenant | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-13 | +| Threat title | SMO Host accesses O-CU Tenant | +| Threat description | The SMO Host accesses the O-CU Tenant through the Shared O-RU. Weak authentication can be exploited by a host to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Tenant | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-14 | +| Threat title | SMO Tenant accesses O-CU Host | +| Threat description | The SMO Tenant accesses the O-CU Host through the Shared O-RU. Weak authentication can be exploited by a host to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Host | + +#### 7.4.9.2 Physical Port Access Threats + +This clause provides threat analysis tables for physical port access threats to Shared O-RU. + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-15 | +| Threat title | Physical port access to Shared O-RU Host/Tenant | +| Threat description | A host, tenant, or third-party gains physical port connectivity to the Shared O-RU. With this physical access the actor exploits weak physical layer authentication to gain access to the Shared O-RU. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-16 | +| Threat title | Physical port access to O-DU Host/Tenant | +| Threat description | A host, tenant, or third-party gains physical port connectivity to a O-DU Host or O-DU Tenant. With this physical access the actor exploits weak physical layer authentication to gain access to the O-DU. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Host, O-DU Tenant | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-17 | +| Threat title | Physical port access to O-CU Host/Tenant | +| Threat description | A host, tenant, or third-party gains physical port connectivity to a O-CU Host or O-CU Tenant. With this physical access the actor exploits weak physical layer authentication to gain access to the O-CU. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Host, O-CU Tenant | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-18 | +| Threat title | Malicious User Login Attempt to SMO Host/Tenant | +| Threat description | The attacker attempts to access the SMO Host or SMO tenant though a management interface. The attacker may be an internal or external actor. Weak account management and/or authentication can be exploited to gain access to move laterally across the deployment for nefarious purposes such as reconnaissance or damage. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO Host, SMO Tenant | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-19 | +| Threat title | Malicious User Login Attempt to O-CU Host/Tenant | +| Threat description | The attacker attempts to access the O-CU Host or O-CU Tenant though a management interface. The attacker may be an internal or external actor. Weak account management and/or authentication can be exploited to gain access to move laterally across the deployment for nefarious purposes such as reconnaissance or damage. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Host, O-CU Tenant | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-20 | +| Threat title | Malicious User Login Attempt to O-DU Host/Tenant | +| Threat description | The attacker attempts to access the O-DU Host or O-DU Tenant though a management interface. The attacker may be an internal or external actor. Weak account management and/or authentication can be exploited to gain access to move laterally across the deployment for nefarious purposes such as reconnaissance or damage. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Host, O-DU Tenant | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-21 | +| Threat title | Malicious User Login Attempt to Shared O-RU Host/Tenant | +| Threat description | The attacker attempts to access the O-RU Host or O-RU Tenant though a management interface. The attacker may be an internal or external actor. Weak account management and/or authentication can be exploited to gain access to move laterally across the deployment for nefarious purposes such as reconnaissance or damage. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | Shared O-RU | + +#### 7.4.9.3 Data Access Threats + +This clause provides threat analysis tables for threats to Shared O-RU data access. + +| Threat ID | T-SharedORU-22 | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Unauthorized internal threat actor gains access to data in Shared O-RU | +| Threat description | Malicious internal threat actor exploits compromised credentials or weak or misconfigured authorization to gain access to view or modify sensitive data-at-rest or data-in-use in the Shared O-RU. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| Threat ID | T-SharedORU-23 | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Unauthorized external threat actor gains access to data in Shared O-RU | +| Threat description | Malicious external threat actor exploits compromised credentials or weak or misconfigured authorization to gain access to view or modify sensitive data-at-rest or data-in-use in the Shared O-RU. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| Threat ID | T-SharedORU-24 | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Data exposure at Shared O-RU | +| Threat description | Data-at-rest on the Shared O-RU is exposed to a tenant. Attacker exploits weak confidentiality protection to view data owned by the MNO Host or a MNO Tenant. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU | + +| Threat ID | T-SharedORU-25 | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Shared O-RU data exposure at SMO | +| Threat description | Data-at-rest on the SMO related to a Shared O-RU is exposed to an unauthorized tenant / SMO user. Attacker exploits weak confidentiality protection to view data owned by the MNO Host or a MNO Tenant of a shared O-RU. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU | + +| Threat ID | T-SharedORU-26 | +|-----------|----------------| +|-----------|----------------| + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Shared O-RU data exposure at O-DU | +| Threat description | Data-at-rest on the O-DU related to a Shared O-RU is exposed to an unauthorized tenant. Attacker exploits weak confidentiality protection to view data owned by the MNO Host or a MNO Tenant of a shared O-RU. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-27 | +| Threat title | Exposed data in transit between Shared O-RU and O-DU Host/Tenant | +| Threat description | Data-in-transit between the Shared O-RU and an O-DU Host or O-DU Tenant could be exposed to another MNO or malicious threat actor. Weak confidentiality protection of data-in-transit allows the host, tenant, or actor to view intercepted data owned by the MNO Host or a MNO Tenant. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU, M-Plane, CUS-Plane | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-28 | +| Threat title | Exposed data in transit between Shared O-RU and SMO Host/Tenant | +| Threat description | Data-in-transit between the Shared O-RU and a SMO Host or SMO Tenant could be exposed to another MNO or malicious threat actor. Weak confidentiality protection of data-in-transit allows the host, tenant, or actor to view intercepted data owned by the MNO Host or a MNO Tenant. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU, O1 | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-43 | +| Threat title | Eavesdropping of unprotected CUSM-plane data within shared O-RU | +| Threat description | The SMO assigns the role of Host and MNO SRO(s). The tenant maliciously or intended is obtaining access to transport protocol stack and is therefore able to eavesdrop sensitive data from neighbor tenants and the host. The tenant may have capability for sniffing/capturing of CUSM-plane data. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU | + +#### 7.4.9.4 Availability Threats + +This clause provides threat analysis tables for availability threats to Shared O-RU. + +| | | +|------------------|----------------| +| Threat ID | T-SharedORU-29 | +|------------------|----------------| + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Modify/Delete OFH C-Plane messages | +| Threat description | A Host MNO, Tenant MNO, or 3 rd -party, modifies or deletes control plane messages on the OFH C-Plane between the Shared O-RU and Host O-DU or Tenant O-DU. This type of integrity attack can also result in an availability attack. | +| Threat type | Tampering | +| Impact type | Integrity, Availability | +| Affected Asset | Shared O-RU, O-DU Host, O-DU Tenant, CUS-Plane | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-30 | +| Threat title | Clock hijacking on OFH S-Plane | +| Threat description | A Host MNO, Tenant MNO, or 3 rd -party takes the role of Grand Master clock on the S-Plane to degrade performance on the U-Plane. This type of authorization exploit can also result in an availability attack. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization, Availability | +| Affected Asset | Shared O-RU, O-DU Host, O-DU Tenant, CUS-Plane | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-31 | +| Threat title | Parameter conflicts at Shared O-RU | +| Threat description | O-DU Host and O-DU Tenants may force conflicting parameter settings at the Shared O-RU that can degrade performance or cause an outage. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-32 | +| Threat title | Volumetric DDoS attack from O-DU targeting Shared O-RU | +| Threat description | An O-DU Host or O-DU Tenant maliciously or unintentionally sends a high-rate of malformed, mis-sequenced, invalid, or valid packets over the Open Fronthaul interface to the Shared O-RU. This kind of attack can cause a Denial of Service on the Shared O-RU. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Shared O-RU, M-Plane, CUS-Plane | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-33 | +| Threat title | Volumetric DDoS attack from SMO targeting Shared O-RU | +| Threat description | The SMO Host maliciously or unintentionally sends a high-rate of malformed, mis-sequenced, invalid, or valid packets over the Open Fronthaul interface to the Shared O-RU. This kind of attack can cause a Denial of Service on the Shared O-RU. | + +| | | +|-----------------------|-------------------| +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Shared O-RU, O1 | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-34 | +| Threat title | Volumetric DDoS attack targeting O-DU | +| Threat description | Shared O-RU maliciously or unintentionally sends a high-rate of malformed, mis-sequenced, invalid, or valid packets over the Open Fronthaul interface to the O-DU Host or O-DU Tenant. This kind of attack can cause a Denial of Service on the O-DU. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | O-DU Host, O-DU Tenant, CUS-Plane, M-Plane | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-35 | +| Threat title | Shared O-RU initialization hijacking by DHCP compromise | +| Threat description | Shared O-RU bootup and initialization sequence depends on parameters passed to it via DHCP options. An attacker can compromise DHCP server and use it to hijack the O-RU and prevent Shared O-RU from reaching carrier-active state. This kind of attack can cause a Denial of Service on the shared O-RU. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-36 | +| Threat title | Shared O-RU M-plane hijacking by DNS compromise | +| Threat description | Shared O-RU M-plane initialization depends on DNS, if FQDN is returned as the NETCONF controller of shared O-RU during its initialization. The name resolution of FQDN can be manipulated by an attacker using a compromised DNS server and prevent Shared O-RU from reaching carrier-active state due to unavailability of carrier configuration. This kind of attack can cause a Denial of Service on the shared O-RU. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Shared O-RU | + +#### 7.4.9.5 Configuration Threats + +This clause provides threat analysis tables for configuration threats to Shared O-RU. + +| | | +|---------------------|-----------------------------------| +| Threat ID | T-SharedORU-37 | +| Threat title | Misconfiguration of MNO Host Role | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | The SMO assigns the role of MNO Host and MNO SRO(s). The assignment of Host role to the wrong SRO can expose data. A threat actor could exploit an incorrectly assigned role of Host to control function of the Shared O-RU | +| Threat type | Information Disclosure, Denial of Service | +| Impact type | Confidentiality, Availability | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-38 | +| Threat title | Incorrect Assignment of Spectrum Resources | +| Threat description | Shared O-RU is responsible for assignment and control of spectrum resources, including component carrier and frequencies within a carrier. Tenant access to the wrong resources, due to malicious intent or could be exploited to gain access to information. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-39 | +| Threat title | Chain of Trust in a Multi-Tenant Environment | +| Threat description | The Chain of Trust is a certificate-based chain used to authenticate an entity. The Chain of Trust is established by validating the hardware and software for the entity up to the root certificate as the trust anchor. The Shared O-RU mutually authenticates O-DU Hosts and O-DU Tenants. Certificates from O-DU tenants must be validated as trustworthy. Malicious actors can exploit untrustworthy certificates to gain access to the Shared O-RU. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | Shared O-RU, O-DU Host, O-DU Tenant, O-CU Host, O-CU Tenant, SMO Host, SMO Tenant | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-40 | +| Threat title | Hijack of MNO Host Role | +| Threat description | The SMO assigns the role of MNO Host and MNO SRO(s). A tenant may maliciously or unintentionally obtain the host role. The elevation of privilege would enable the tenant, acting as host, to have authorized access on the Shared O-RU to sensitive data, credentials, and system privileges. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|---------------------|-------------------------------------------| +| Threat ID | T-SharedORU-41 | +| Threat title | Not Released Host Role (Host Role resume) | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | The SMO assigns the role of Host and MNO SRO(s). The tenant maliciously or intended is obtaining the host role, and implicit has obtained elevated privileges which could be used to drive wrong things, like obtaining of sensitive data and/or driving DoS. The tenant is not releasing the host role and/or the tenant is reusing known sensitive information and is driving wrong things. How to avoid that a tenant who has become once in his/her life a host is obtaining information that could be misused now and in the future. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-42 | +| Threat title | Misuse of “sudo” privileges | +| Threat description | The SMO assigns the role of Host and MNO SRO(s). The tenant maliciously or intended is obtaining the host role, and implicit has obtained elevated privileges which could be used to drive wrong things, like obtaining of sensitive data and/or driving DoS. How to avoid that any of the tenants can misuse the “sudo” privileges. This includes the default credentials of a shared O-RU. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-55 | +| Threat title | Set Incorrect Array-Carrier configuration on O-DU (Standby) | +| Threat description | Threat actor spoofs SMO to set or modify the pre-configured array-carrier configuration on the O-DU in Standby state. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | O-DU, O1 interface | + +| | | +|---------------------------|----------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-56 | +| Threat title | Modify Array-Carrier pre-configuration on Shared O-RU | +| Threat description | Threat actor can gain access to Shared O-RU to modify its pre-configured array-carrier | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|---------------------|-----------------------------------------------------------------| +| Threat ID | T-SharedORU-57 | +| Threat title | Modify/Inject M-Plane messages with Array-Carrier configuration | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------| +| Threat description | Threat actor Modifies/Injects M-Plane messages with Array-Carrier configuration sent to the Shared O-RU. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | Shared O-RU, M-Plane | + +#### 7.4.9.6 Resiliency Threats + +This clause provides threat analysis tables for threats introduced by the O-DU Resiliency use case. + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-52 | +| Threat title | Thrashing O-DU Failovers | +| Threat description | Threat actor spoofs SMO to cause O-DU-1 and O-DU-2 to thrash between Active state and Standby state | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | O-DU, O1 interface | + +| | | +|--------------------|--------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-53 | +| Threat title | Dual (Dueling) Active O-DUs | +| Threat description | Threat actor spoofs SMO to cause O-DU-1 and O-DU-2 to both be in Active state. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | O-DU, O1 interface | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-54 | +| Threat title | Modify/Inject O1 messages at the SMO | +| Threat description | Threat actor spoofs O-DU to modify, inject, flood O1 messages to the SMO to prevent SMO detection of O-DU failure. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | SMO, O1 interface | + +## 7.5 Coverage matrix of threats + +From the above threats, a threat inventory is developed to provide a mapping between threats, vulnerabilities and assets. For the purposes of this document, threats have been grouped into two categories: + +1. ‘O-RAN specific’ comprises threats directly relating to O-RAN components and interfaces +2. ‘General’ covers threats relating to physical, open source, virtualization, IoT and radio aspects + +The threat inventory provides details of each individual threat: threat agents, vulnerabilities, threatened assets and affected components. + +Table 7-1 : O-RAN Threat Inventory + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|-------------------------------|---------------------------------------------------------------------------------------------------------------------------|--------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------|---------------------------------------------------------| +| O-RAN specific threats | | | | | | +| T-O-RAN-01 | An attacker exploits insecure designs or lack of adaption in O-RAN components | All |
    • Outdated component from the lack of update or patch management
    • Poorly design architecture
    • Missing appropriate security hardening
    • Unnecessary or insecure function/protocol/component
    | All | All | +| T-O-RAN-02 | An attacker exploits misconfigured or poorly configured O-RAN components | All |
    • Errors from the lack of configuration change management
    • Misconfigured or poorly configured O-RAN components
    • Improperly configured permissions
    • Unnecessary features are enabled (e.g. unnecessary ports, services, accounts, or privileges)
    • Default accounts and their passwords still enabled and unchanged
    • Security features are disabled or not configured securely
    | All | All | +| T-O-RAN-03 | Attacks from the internet to penetrate O-RAN network boundary | All | Errors in the design and implementation of the network protocols (HTTP, P, TCP, UDP, application protocols) | All | All | +| T-O-RAN-04 | An attacker attempts to jam the airlink signal through IoT devices | All | Failure to address overload situations | ASSET-D-06, ASSET-D-18 | O-RU, airlink with UE, O-DU | +| T-O-RAN-05 | An attacker penetrates and compromises the O-RAN system through the open O-RAN's Fronthaul, O1, O2, A1, and E2 | All |
    • Improper or missing authentication and authorization processes
    • Improper or missing ciphering and integrity checks of sensitive data exchanged over O-RAN interfaces
    • Improper or missing replay protection of sensitive data exchanged over O-RAN interfaces
    • Improper prevention of key reuse
    | All | rApps, xApps, O-RU, O-DU, O-CU, Near-RT RIC, Non-RT RIC | +| T-O-RAN-06 | An attacker exploits insufficient/improper mechanisms for authentication and authorization to compromise O-RAN components | All |
    • Unauthenticated access to O-RAN functions
    • Improper authentication mechanisms
    • Use of Predefined/ default accounts
    • Weak or missing password policy
    • Lack of mutual authentication to O-RAN components and interfaces
    • Failure to block consecutive failed login attempts
    • Improper authorization and access control policy
    | All | All | +| T-O-RAN-07 | An attacker compromises O-RAN monitoring mechanisms and log files integrity and availability | All |
    • Lack of security event logging
    • Insufficient protection of log files
    | ASSET-D-29 | All | +| T-O-RAN-08 | An attacker compromises O-RAN data integrity, confidentiality and traceability | All |
    • Improper or missing ciphering of sensitive data in storage or in transfer
    • Improper or missing integrity mechanisms to protect sensitive data in storage or in transfer
    • Presence of active function(s) that reveal confidential internal data
    • No traceability (logging) of access to personal data
    | ASSET-D-01 to ASSET-D-29 | All | +| T-O-RAN-09 | An attacker compromises O-RAN components integrity and availability | All |
    • Improper handling of overload situations
    • Unrestricted boot memory devices
    • Lack of / improper mechanisms for Network Product software package integrity validation
    | ASSET-C-01 to ASSET-C-12 | All | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|--------------|---------------------------------------------------------------------------------------------------------------------------|--------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------|---------------------------------------------------------| +| T-O-RAN-10 | Inconsistent Log Format Impeding Effective Attack Detection | All |
    • Lack of Centralized Log Management: Without a centralized system to collect and analyse logs, it's difficult to correlate events across different systems, which can obscure the detection of attack patterns.
    • Lack of Log Standardization: Different systems generating logs in various formats can lead to inconsistencies in the data, making it difficult to aggregate and analyse logs effectively.
    • Limited Log Analysis Capabilities: Even with centralized logs, if the analysis tools or processes are not up to the task, potential threats may still go undetected.
    • Inconsistent Time Synchronization: Without synchronized time across systems, it becomes challenging to correlate log entries accurately, which is crucial for tracking attackers' movements and actions.
    | All | All | +| T-FRHAUL-01 | An attacker penetrates O-DU and beyond through O-RU or the Fronthaul interface to access or modify sensitive information | All | Heterogeneous security levels between O-RU and O-DU provided by different vendors | ASSET-D-01, ASSET-D-02, ASSET-D-04, ASSET-D-05 | rApps, xApps, O-RU, O-DU, O-CU, Near-RT RIC, Non-RT RIC | +| T-FRHAUL-01A | An attacker penetrates O-DU and beyond through O-RU or the Fronthaul interface to impersonate a legitimate system or user | All | Heterogeneous security levels between O-RU and O-DU provided by different vendors | ASSET-D-01, ASSET-D-02, ASSET-D-04, ASSET-D-05 | rApps, xApps, O-RU, O-DU, O-CU, Near-RT RIC, Non-RT RIC | +| T-FRHAUL-02 | Unauthorized access to Open Front Haul Ethernet L1 physical layer interface(s) to obtain protected information | All | Lack of authentication and access control to the Open Front Haul Ethernet L1 physical layer interface | ASSET-D-01, ASSET-D-02, ASSET-D-04, ASSET-D-05 | rApps, xApps, O-RU, O-DU, O-CU, Near-RT RIC, Non-RT RIC | +| T-FRHAUL-03 | Unauthorized access to Open Front Haul Ethernet L1 physical layer interface(s) to disrupt services | All | Lack of authentication and access control to the Open Front Haul Ethernet L1 physical layer interface | ASSET-D-01, ASSET-D-02, ASSET-D-04, ASSET-D-05 | rApps, xApps, O-RU, O-DU, O-CU, Near-RT RIC, Non-RT RIC | +| T-MPLANE-01 | An attacker attempts to intercept the Fronthaul (MITM) over M Plane to obtain protected information | All | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | ASSET-D-02, ASSET-D-03 | Near-RT RIC, Non-RT RIC, O-CU, O-DU, SMO | +| T-MPLANE-02 | An attacker attempts to intercept the Fronthaul (MITM) over M Plane to alter m-plane data | All | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | ASSET-D-02, ASSET-D-03 | Near-RT RIC, Non-RT RIC, O-CU, O-DU, SMO | +| T-MPLANE-03 | An attacker attempts to intercept the Fronthaul (MITM) over M Plane to disrupt services | All | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | ASSET-D-02, ASSET-D-03 | Near-RT RIC, Non-RT RIC, O-CU, O-DU, SMO | +| T-SPLANE-01 | DoS attack against a Master clock | All |
    • Improper process to monitor and manage the performance of the Master clock
    • ANNOUNCE messages can be sent publicly in clear text
    | ASSET-D-01 | O-DU, O-RU | +| T-SPLANE-02 | Impersonation of a Master clock (Spoofing) within a PTP network with a fake ANNOUNCE message | All |
    • Inaccurate timing information
    • Improper synchronization between clocks
    • ANNOUNCE messages can be sent publicly in clear text
    | ASSET-D-01 | O-DU, O-RU | +| T-SPLANE-03 | A Rogue PTP Instance wanting to be a Grand Master | All |
    • Inaccurate timing information
    • Improper synchronization between clocks
    • ANNOUNCE messages can be sent publicly in clear text
    | ASSET-D-01 | O-DU, O-RU | +| T-SPLANE-04 | Selective interception and removal of PTP timing packets | All |
    • Inaccurate timing information
    • Improper synchronization between clocks
    • ANNOUNCE messages can be sent publicly in clear text
    | ASSET-D-01 | O-DU, O-RU | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|---------------|--------------------------------------------------------------------------------------------------------------------------------------------------------|--------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------| +| T-SPLANE-05 | Packet delay manipulation attack | All |
    • Inaccurate timing information
    • Improper synchronization between clocks
    • ANNOUNCE messages can be sent publicly in clear text
    | ASSET-D-01 | O-DU, O-RU | +| T-CPLANE-01 | Spoofing of DL C-plane messages | All | Lack of authentication could allow an adversary to inject DL C-plane messages | ASSET-D-04 | O-DU, O-RU | +| T-CPLANE-02 | Spoofing of UL C-plane messages | All | Lack of authentication could allow an adversary to inject UL C-plane messages | ASSET-D-04 | O-DU, O-RU | +| T-UPLANE-01 | An attacker attempts to intercept the Fronthaul (MITM) over U-Plane to obtain user data | All | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | ASSET-D-05 | O-DU, O-RU | +| T-UPLANE-02 | An attacker attempts to intercept the Fronthaul (MITM) over U-Plane to modify u-plane data | All | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | ASSET-D-05 | O-DU, O-RU | +| T-UPLANE-03 | An attacker attempts to intercept the Fronthaul (MITM) over U-Plane to disrupt services | All | Lack of sufficient security measures in the Fronthaul due to the negative impact on the performance requirements | ASSET-D-05 | O-DU, O-RU | +| T-UPLANE-04 | Spoofing and unauthorized access of U-Plane data packets | All | Lack of authentication, and authorization protection for U-Plane data packets | ASSET-D-05 | O-DU, O-RU | +| T-ORU-01 | An attacker stands up a false base station attack by attacking an O-RU | All | False O-RUs | ASSET-D-01, ASSET-D-02, ASSET-D-03, ASSET-D-04, ASSET-D-05, ASSET-D-06 | O-RU | +| T-O-RU-02 | An attacker leverages the lack of traceability with shared user accounts | All |
    • Identical local user accounts are shared across entities(eg:SMO, O-DU) for concurrent access
    | ASSET-D-18
    ASSET-D-20 | ASSET-C-06 | +| T-O-RU-03 | An attacker manipulates initial provisioning information | All |
    • Initial provisioning information from the Software configuration server could be manipulated to point to another server rather than the centralized authentication and authorization server
    | ASSET-D-18
    ASSET-D-20 | ASSET-C-06 | +| T-O-RU-04 | An attacker compromises O-RU user information, data integrity, confidentiality towards an external centralized authentication and authorization server | All |
    • O-RU credentials including account information and passwords could be mismanaged, misclassifying O-RU users between centralized and local users which could defeat the purpose of central authentication, authorization and administration
    • Data in plain text between the O-RU and centralized Authentication and authorization server could be manipulated
    • O-RU related credentials can be manipulated if not stored securely
    | ASSET-D-20 | ASSET-C-06

    ASSET-C-26 | +| T-NEAR-RT-01 | Malicious Apps can exploit UE identification, track UE location and change UE priority | All | Malicious xApps may be used to gain access to UE identification location and priority | ASSET-D-21, ASSET-D-22, ASSET-C-02, ASSET-C-09, ASSET-C-41, ASSET-C-43 | Near-RT RIC, xApps, E2 Functions, Y1 Functions | +| T-NEAR-RT-02 | Risk of a malicious xApp on Near-RT RIC to obtain protected information | All | Improper or missing authentication and authorization of xApps | ASSET-D-10, ASSET D-11, ASSET D-21, ASSET-D-22 | Near-RT RIC, UE, xApps | +| T-NEAR-RT-02A | Risk of a malicious xApp on Near-RT RIC impacting service availability | All | Improper or missing authentication and authorization of xApps | ASSET-D-10, ASSET D-11, ASSET D-21, ASSET-D-22 | Near-RT RIC, UE, xApps | +| T-NEAR-RT-03 | Attackers exploit non authenticated, weakly or incorrectly authenticated Near-RT RIC APIs to obtain protected information | All | Non authenticated, weakly or incorrectly authenticated Near-RT RIC APIs | ASSET-D-09, ASSET-D-10, ASSET D-11, ASSET D-20, ASSET-D-21, ASSET-D-25, ASSET-D-26, ASSET-D-29, ASSET-D-30, ASSET-C-02, ASSET-C-09, ASSET-C-41, ASSET-C-43 | Near-RT RIC, UE, xApps | +| T-NEAR-RT-03A | Attackers exploit non authenticated, weakly or incorrectly authenticated Near-RT RIC APIs for MiTM attacks | All | Non authenticated, weakly or incorrectly authenticated Near-RT RIC APIs | ASSET-D-09, ASSET-D-10, ASSET D-11, ASSET D-20, ASSET-D-21, ASSET-D-25, | Near-RT RIC, UE, xApps | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|---------------|---------------------------------------------------------------------------------------------------------------------------------------------------------|--------------|-----------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------| +| | | | | ASSET-D-26, ASSET-D-29, ASSET-D-30, ASSET-C-02, ASSET-C-09, ASSET-C-41, ASSET-C-43 | | +| T-NEAR-RT-04 | Attackers exploit non authorized Near-RT RIC APIs to access resources and services which they are not entitled to use, to obtain protected information. | All | Non-authorized RT RIC APIs | ASSET-D-09, ASSET-D-10, ASSET D-11, ASSET D-20, ASSET-D-21, ASSET-D-25, ASSET-D-26, ASSET-D-29, ASSET-D-30, ASSET-C-02, ASSET-C-09, ASSET-C-41, ASSET-C-43 | Near-RT RIC, UE, xApps | +| T-NEAR-RT-04A | Attackers exploit non authorized Near-RT RIC APIs to access resources and services which they are not entitled to use, to disrupt services. | All | Non-authorized RT RIC APIs | ASSET-D-09, ASSET-D-10, ASSET D-11, ASSET D-20, ASSET-D-21, ASSET-D-25, ASSET-D-26, ASSET-D-29, ASSET-D-30, ASSET-C-02, ASSET-C-09, ASSET-C-41, ASSET-C-43 | Near-RT RIC, UE, xApps | +| T-NEAR-RT-05 | Attackers exploit non uniquely identified xApps using a trusted xAppID to access resources and services which they are not entitled to use. | All | Not uniquely identifying xApps using a trusted xAppID | ASSET-D-39, ASSET-C-02, ASSET-C-09 | Near-RT RIC, xApps | +| T-NONRTRIC-01 | An attacker gains access to the Non-RT RIC through the SMO to cause a denial of service or degrade the performance of the Non-RT RIC | All | Improper or missing authentication and authorization processes on the Non-RT RIC or SMO | ASSET-D-03, ASSET-D-07, ASSET-D-08, ASSET-C-11 | Non-RT RIC, rApps | +| T-NONRTRIC-02 | An attacker gains access to the Non-RT RIC through the SMO for UE tracking | All | Malicious rApps may be used to gain access to UE identification | ASSET-D-21, ASSET-D-22, ASSET-C-11 | Non-RT RIC, rApps, UE | +| T-NONRTRIC-03 | An attacker gains access to the Non-RT RIC through the SMO to cause Data Corruption/Modification | All | Improper or missing authentication and authorization processes on the Non-RT RIC or SMO | ASSET-C-11 | Non-RT RIC | +| T-NONRTRIC-04 | An attacker exploits non uniquely identified rApp instances using a trusted rAppID to access R1 services and data which they are not entitled to use | All | Not uniquely identifying rApp instances using a trusted rAppID | ASSET-C-10, ASSET-C-11 | Non-RT RIC, rApps | +| T-xAPP-01 | An attacker exploits xApps vulnerabilities and misconfiguration to alter data transmitted over A1 or E2 interfaces. | All | xApp stems from an untrusted or unmaintained source | ASSET-C-03, ASSET-C-05, ASSET-C-07, ASSET-C-08, ASSET-C-09, ASSET-C-10 | O-CU, Near-RT RIC, xApps | +| T-xAPP-01A | An attacker exploits xApps vulnerabilities and misconfiguration to extract sensitive information. | All | xApp stems from an untrusted or unmaintained source | ASSET-C-03, ASSET-C-05, ASSET-C-07, ASSET-C-08, ASSET-C-09, ASSET-C-10 | O-CU, Near-RT RIC, xApps | +| T-xAPP-01B | An attacker exploits xApps vulnerabilities and misconfiguration to disrupt Near-RT RIC functions | All | xApp stems from an untrusted or unmaintained source | ASSET-C-03, ASSET-C-05, ASSET-C-07, ASSET-C-08, ASSET-C-09, ASSET-C-10 | O-CU, Near-RT RIC, xApps | +| T-xAPP-01C | An attacker exploits xApps vulnerabilities and misconfiguration to gain unauthorized control over Near-RT RIC | All | xApp stems from an untrusted or unmaintained source | ASSET-C-03, ASSET-C-07, ASSET-C-08, ASSET-C-09, ASSET-C-10 | O-CU, Near-RT RIC, xApps | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|-----------|-----------------------------------------------------------------------------------------------|--------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------|--------------------------------| +| T-xAPP-02 | Conflicting xApps impact O-RAN system functions to degrade performance or create a DoS [i.12] | All |
    • xApps may be misconfigured or compromised
    • Failing or misconfigured authentication and authorization in xApp
    | ASSET-C-03, ASSET-C-05, ASSET-C-07, ASSET-C-08, ASSET-C-09, ASSET-C-10 | O-CU, Near-RT RIC, xApps | +| T-xAPP-03 | An attacker compromises xApp isolation | All | Vulnerabilities in the underlying system hosting xApps | ASSET-C-03, ASSET-C-07, ASSET-C-08, ASSET-C-09, ASSET-C-10 | O-CU, Near-RT RIC, xApps | +| T-xApp-04 | False or malicious A1 policies modify behavior of xApps | All | xApp functionality exploited by malicious A1 policies | ASSET-D-07, ASSET-D-11, ASSET-C-09 | O-CU, O-DU, Near-RT RIC, xApps | +| T-rAPP-01 | Conflicting rApps impact O-RAN system functions to degrade performance or trigger a DoS | All | rApp stems from an untrusted or unmaintained source | ASSET-C-10 | rApps, Non-RT RIC | +| T-rAPP-02 | An attacker exploits rApp vulnerability for data breach or denial of service | All | rApp management is exposed to the tenant in a web front-end or REST API. These interfaces may contain software vulnerabilities or implement authentication and authorization insufficiently. | ASSET-C-10 | rApps, Non-RT RIC | +| T-rAPP-03 | An attacker exploits rApps misconfiguration | All | Vulnerabilities in the underlying system hosting rApps | ASSET-C-10 | rApps, Non-RT RIC | +| T-rAPP-04 | An attacker bypasses authentication and authorization | All |
    • rApps may be misconfigured or compromised
    • Failing or misconfigured authentication and authorization in rApp
    | ASSET-C-10 | rApps, Non-RT RIC | +| T-rAPP-05 | An attacker deploys and exploits malicious rApp | All |
    • rApps may be misconfigured or compromised
    • Failing or misconfigured authentication and authorization in rApp
    | ASSET-C-10 | rApps, Non-RT RIC | +| T-rAPP-06 | An attacker bypasses authentication and authorization using an injection attack | All |
    • rApps may be misconfigured or compromised
    • Failing or misconfigured authentication and authorization in rApp
    | ASSET-C-10 | rApps, Non-RT RIC | +| T-rAPP-07 | rApp exploits services | All |
    • rApps may be misconfigured or compromised
    • Failing or misconfigured authentication and authorization in rApp
    | ASSET-C-10 | rApps, Non-RT RIC | +| T-PNF-01 | An attacker compromises a PNF to launch attacks against VNFs/CNFs | All | Vulnerabilities in a PNF deployed in a PNF-VNF/CNF deployments. | All | All | +| T-PNF-01A | An attacker compromises a PNF to launch Denial of Service attacks against VNFs/CNFs | All | Vulnerabilities in a PNF deployed in a PNF-VNF/CNF deployments. | All | All | +| T-SMO-01 | External attacker exploits authentication weakness on SMO | All | Missing or improperly configured authentication | ASSET-C-11, ASSET-C-17 | Non-RT RIC, SMO Framework | +| T-SMO-02 | External attacker exploits authorization weakness on SMO | All | Missing or improperly configured authorization | ASSET-C-11, ASSET-C-17 | Non-RT RIC, SMO Framework | +| T-SMO-03 | External Overload DoS attack targeted at SMO | All | Lack of overload protection and rate-limiting | ASSET-C-11, ASSET-C-17 | Non-RT RIC, SMO Framework | +| T-SMO-04 | Internal attacker exploits authentication weakness on a SMO function | All | Missing or improperly configured authentication | ASSET-C-11, ASSET-C-17, ASSET-C-18, ASSET-C-19, ASSET-C-20, ASSET-C 21 | All | +| T-SMO-05 | Internal attacker exploits authorization weakness on a SMO function | All | Missing or improperly configured authorization | ASSET-C-11, ASSET-C-17, ASSET-C-18, ASSET-C-19, ASSET-C-20, ASSET-C 21 | All | +| T-SMO-06 | Internal Overload DoS attack targeted at SMO functions | All | Lack of overload protection and rate-limiting | ASSET-C-11, ASSET-C-17, ASSET-C-18, ASSET-C-19, ASSET-C-20, ASSET-C 21 | All | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|-----------|-------------------------------------------------------------------------------------------------------------------|--------------|---------------------------------------------------------------|------------------------------------------------------------------------|---------------------------------------------------| +| T-SMO-07 | Internal DoS attack disables internal SMO function(s) or process(es) | All | Privilege escalation or improperly configured authorization | ASSET-C-11, ASSET-C-17, ASSET-C-18, ASSET-C-19, ASSET-C-20, ASSET-C 21 | All | +| T-SMO-08 | Attacker exploits insecure API to gain access to SMO | All | API vulnerability | ASSET-C-11, ASSET-C-17, ASSET-C-18, ASSET-C-19, ASSET-C-20, ASSET-C 21 | All | +| T-SMO-09 | Sensitive data in transit is exposed to an internal attacker | All | Missing or weak confidentiality protection of data in transit | ASSET-C-11, ASSET-C-17, ASSET-C-18, ASSET-C-19, ASSET-C-20, ASSET-C 21 | All | +| T-SMO-10 | Sensitive data at rest is exposed to an internal attacker | All | Missing or weak confidentiality protection of data at rest | ASSET-C-11, ASSET-C-17, ASSET-C-18, ASSET-C-19, ASSET-C-20, ASSET-C 21 | All | +| T-SMO-11 | AI/ML poisoning by internal attacker | All | Missing integrity protection of data at rest | ASSET-C-11, ASSET-C-17 | Non-RT RIC, SMO Framework | +| T-SMO-12 | AI/ML exposure on external entity | All | Missing or weak confidentiality protection of data at rest | ASSET-C-11, ASSET-C-17 | Non-RT RIC, SMO Framework | +| T-SMO-13 | Malicious actor views local logs | All | Missing or weak confidentiality protection of data at rest | ASSET-C-17, ASSET-C-18 | SMO Framework, SMO Functions | +| T-SMO-14 | Malicious actor modifies local log entries | All | Missing integrity protection of data at rest | ASSET-C-17, ASSET-C-18 | SMO Framework, SMO Functions | +| T-SMO-15 | Malicious actor deletes local logs | All | Missing integrity protection of data at rest | ASSET-C-17, ASSET-C-18 | SMO Framework, SMO Functions | +| T-SMO-16 | Malicious actor intercepts exports of local logs | All | Missing or weak confidentiality protection of data in transit | ASSET-C-17, ASSET-C_18, ASSET-C-26 | SMO Framework, SMO Functions, External interfaces | +| T-SMO-17 | Malicious external actor gains unauthorized access to logs | All | Missing or improperly configured authorization | ASSET-C-17, ASSET-C-18 | SMO Framework, SMO Functions | +| T-SMO-18 | Malicious internal actor gains authorized access to logs | All | Missing or improperly configured authorization | ASSET-C-17, ASSET-C-18 | SMO Framework, SMO Functions | +| T-SMO-19 | Internal attacker exploits O2 interface to view data in transit between SMO and O-Cloud | All | Missing or weak confidentiality protection of data in transit | ASSET-C_08, ASSET-C-17, ASSET-C-23 | O-Cloud, SMO, O2 interface | +| T-SMO-20 | Internal attacker exploits O2 interface to modify data in transit between SMO and O-Cloud | All | Missing integrity checking for data in transit | ASSET-C_08, ASSET-C-17, ASSET-C-23 | O-Cloud, SMO, O2 interface | +| T-SMO-21 | Internal attacker uses O2 interface via SMO to exploit API vulnerability to gain access to O-Cloud infrastructure | All | API vulnerability | ASSET-C_08, ASSET-C-17, ASSET-C-23 | O-Cloud, SMO, O2 interface | +| T-SMO-22 | Internal attacker floods O2 interface via SMO to cause DDoS on O-Cloud infrastructure | All | Lack of overload protection and rate-limiting | ASSET-C-08, ASSET-C-17, ASSET-C-23 | O-Cloud, SMO, O2 interface | +| T-SMO-23 | External attacker uses O2 interface via O-Cloud to exploit API vulnerability to gain access to SMO | All | API vulnerability | ASSET-C_08, ASSET-C-17, ASSET-C-23 | O-Cloud, SMO, O2 interface | +| T-SMO-24 | External attacker floods O2 interface via O-Cloud to cause DDoS on SMO | All | Lack of overload protection and rate-limiting | ASSET-C_08, ASSET-C-17, ASSET-C-23 | O-Cloud, SMO, O2 interface | +| T-SMO-25 | External attacker uses O2 interface via O-Cloud to gain authorized access to sensitive data-at-rest at the SMO | All | Missing or improperly configured authorization | ASSET-C_08, ASSET-C-17, ASSET-C-23 | O-Cloud, SMO, O2 interface | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|-------------|----------------------------------------------------------------------------------------------------------|--------------|---------------------------------------------------------------|------------------------------------------------------------|--------------------------------------| +| T-SMO-26 | External attacker exploits External interface to view data in transit between SMO and external service | All | Missing or weak confidentiality protection of data in transit | ASSET-C_11, ASSET-C-17, ASSET-C-26 | Non-RT RIC, SMO, External interfaces | +| T-SMO-27 | External attacker exploits External interface to modify data in transit between SMO and external service | All | Missing integrity checking for data in transit | ASSET-C_11, ASSET-C-17, ASSET-C-26 | Non-RT RIC, SMO, External interfaces | +| T-SMO-28 | External attacker uses External interface to exploit API vulnerability to gain access to SMO | All | API vulnerability | ASSET-C_11, ASSET-C-17, ASSET-C-26 | Non-RT RIC, SMO, External interfaces | +| T-SMO-29 | External attacker floods External interface to cause DDoS at SMO | All | Lack of overload protection and rate-limiting | ASSET-C_11, ASSET-C-17, ASSET-C-26, ASSET-C_27, ASSET-C-28 | All | +| T-SMO-30 | External attacker uses External interface to gain access to sensitive data-at-rest at the SMO | All | Missing or improperly configured authorization | ASSET-C_11, ASSET-C-17, ASSET-C-26 | Non-RT RIC, SMO, External interfaces | +| T-SMO-31 | External attacker poisons External AI/ML data to corrupt SMO | All | Missing integrity checking for data at rest | ASSET-C_11, ASSET-C-17, ASSET-C-26 | Non-RT RIC, SMO, External interfaces | +| T-SMO-32 | External attacker poisons External Enrichment Information data sources to corrupt SMO | All | Missing integrity checking for data at rest | ASSET-C_11, ASSET-C-17, ASSET-C-26 | Non-RT RIC, SMO, External interfaces | +| T-R1-01 | A malicious actor gains unauthorized access to R1 services | All | weak mutual authentication | ASSET-C-16 | R1 interface | +| T-R1-02 | Attacker modifies Service Heartbeat message to cause Denial of Service | All | weak mutual authentication | ASSET-C-16 | R1 interface | +| T-R1-03 | Malicious actor bypasses authentication to Request Data | All | weak mutual authentication | ASSET-C-16 | R1 interface | +| T-R1-04 | Malicious actor bypasses authorization to Discover Data | All | weak mutual authentication | ASSET-C-16 | R1 interface | +| T-R1-05 | A malicious actor gains unauthorized access to data | All | weak mutual authentication | ASSET-C-16 | R1 interface | +| T-R1-06 | Malicious actor modifies a Data Request | All | weak mutual authentication | ASSET-C-16 | R1 interface | +| T-R1-07 | Malicious actor compromises Data Delivery to the Data Consumer | All | weak mutual authentication | ASSET-C-16 | R1 interface | +| T-A1-01 | Untrusted peering between Non-RT-RIC and Near-RT-RIC | All | weak mutual authentication | ASSET-C-14 | A1 interface | +| T-A1-02 | Malicious function or application monitors messaging across A1 interface | All | weak mutual authentication | ASSET-C-14 | A1 interface | +| T-A1-03 | Malicious function or application modifies messaging across A1 interface | All | weak mutual authentication | ASSET-C-14 | A1 interface | +| T-A1-04 | Unauthorized access to Non-RT-RIC- or Near-RT-RIC- resources | All | weak service consumer authorization | ASSET-D-07, ASSET-D-08 | A1 interface | +| T-AppLCM-01 | Compromise of App/VNF/CNF update package integrity during onboarding | All | Lack of integrity verification | ASSET-D-15 | Apps/VNFs/CNFs | +| T-AppLCM-02 | Compromise of App/VNF/CNF update image integrity during instantiation | All | Lack of integrity verification | ASSET-D-15 | Apps/VNFs/CNFs images | +| T-AppLCM-03 | Downgrade attack to vulnerable application version | All | Lack of integrity verification | ASSET-D-15 | Apps/VNFs/CNFs | +| T-AppLCM-04 | Attacker exploits missing or improperly defined elements of application's SecurityDescriptor | All | Misconfiguration | ASSET-D-15 | Apps/VNFs/CNFs | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|----------------|-----------------------------------------------------------|--------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------|-------------------------------------| +| T-AppLCM-05 | Malicious actor modifies application's SecurityDescriptor | All | Lack of authentication, lack of integrity verification | ASSET-D-15 | Apps/VNFs/CNFs | +| T-AppLCM-06 | Improper decommissioning of application | All | Improper release of resources and secrets | ASSET-D-15 | Apps/VNFs/CNFs | +| T-AppLCM-07 | Improper deletion of application sensitive data | All | Missing or weak confidentiality protection | ASSET-D-16, ASSET-D-17, ASSET-D-32 | Apps/VNFs/CNFs | +| T-SharedORU-01 | O-DU Tenant accesses O-DU Host | All | Weak authentication can be exploited by a tenant to move laterally across the deployment. | ASSET-C-34 | O-DU Host | +| T-SharedORU-02 | O-DU Host accesses O-DU Tenant | All | Weak authentication can be exploited by a host to move laterally across the deployment. | ASSET-C-35 | O-DU Tenant | +| T-SharedORU-03 | O-DU Tenant accesses O-DU Tenant | All | Weak authentication can be exploited by a tenant to move laterally across the deployment. | ASSET-C-35 | O-DU Tenant | +| T-SharedORU-04 | Password Attack on OFH M-Plane | All | The attack can be a brute-force attack or stolen password. There is increased risk of password attack in a multi-tenant environment. | ASSET-C-31, ASSET-C-34, ASSET-C-35 | Shared O-RU, O-DU Host, O-DU Tenant | +| T-SharedORU-05 | Untrusted peering to O-DU | All | Attacker exploits weak authentication on the O-DU to establish a session with a malicious app masquerading as a Shared O-RU. From the O-DU, a malicious actor can move laterally. | ASSET-C-34, ASSET-C-35 | O-DU Host, O-DU Tenant | +| T-SharedORU-06 | Untrusted peering to the Shared O-RU | All | Weak authentication can be exploited to establish session with a malicious app masquerading as a O-DU Host or O-DU Tenant | ASSET-C-31 | Shared O-RU | +| T-SharedORU-07 | Untrusted peering to the SMO | All | Weak authentication on the SMO can be exploited to establish session with a malicious app masquerading as a Shared O-RU. | ASSET-C-31 | Shared O-RU | +| T-SharedORU-08 | SMO Tenant accesses SMO Host | All | Weak authentication can be exploited by a tenant to move laterally across the deployment. | ASSET-C-38 | SMO Host | +| T-SharedORU-09 | SMO Host accesses SMO Tenant | All | Weak authentication can be exploited by a tenant to move laterally across the deployment. | ASSET-C-39 | SMO Tenant | +| T-SharedORU-10 | O-DU Host accesses O-CU Tenant | All | Weak authentication can be exploited by a tenant to move laterally across the deployment. | ASSET-C-37 | O-CU Tenant | +| T-SharedORU-11 | O-DU Tenant accesses O-CU Host | All | Weak authentication can be exploited by a tenant to move laterally across the deployment. | ASSET-C-36 | O-CU Host | +| T-SharedORU-12 | O-DU Tenant accesses O-CU Tenant | All | Weak authentication can be exploited by a tenant to move laterally across the deployment. | ASSET-C-37 | O-CU Tenant | +| T-SharedORU-13 | SMO Host accesses O-CU Tenant | All | Weak authentication can be exploited by a tenant to move laterally across the deployment. | ASSET-C-37 | O-CU Tenant | +| T-SharedORU-14 | SMO Tenant accesses O-CU Host | All | Weak authentication can be exploited by a tenant to move laterally across the deployment. | ASSET-C-36 | O-CU Host | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|----------------|------------------------------------------------------------------------|--------------|----------------------------------------------------------------------------------------------------------------|------------------------------------------------|------------------------------------------------| +| T-SharedORU-15 | Physical port access to Shared O-RU Host/Tenant | All | Weak physical layer authentication can be exploited to gain access. | ASSET-C-31 | Shared O-RU | +| T-SharedORU-16 | Physical port access to O-DU Host/Tenant | All | Weak physical layer authentication can be exploited to gain access. | ASSET-C-34, ASSET-C-35 | O-DU Host, O-DU Tenant | +| T-SharedORU-17 | Physical port access to O-CU Host/Tenant | All | Weak physical layer authentication can be exploited to gain access. | ASSET-C-36, ASSET-C-37 | O-CU Host, O-CU Tenant | +| T-SharedORU-18 | Malicious User Login Attempt to SMO Host/Tenant | All | Weak account management and/or authentication can be exploited to gain access. | ASSET-C-38, ASSET-C-39 | SMO Host, SMO Tenant | +| T-SharedORU-19 | Malicious User Login Attempt to O-CU Host/Tenant | All | Weak account management and/or authentication can be exploited to gain access | ASSET-C-36, ASSET-C-37 | O-CU Host, O-CU Tenant | +| T-SharedORU-20 | Malicious User Login Attempt to O-DU Host/Tenant | All | Weak account management and/or authentication can be exploited to gain access | ASSET-C-32, ASSET-C-33 | O-DU Host, O-DU Tenant | +| T-SharedORU-21 | Malicious User Login Attempt to Shared O-RU Host/Tenant | All | Weak account management and/or authentication can be exploited to gain access | ASSET-C-31 | Shared O-RU | +| T-SharedORU-22 | Unauthorized internal threat actor gains access to data in Shared O-RU | All | Compromised credentials or weak or misconfigured authorization to gain access to view or modify sensitive data | ASSET-C-31 | Shared O-RU | +| T-SharedORU-23 | Unauthorized external threat actor gains access to data in Shared O-RU | All | Compromised credentials or weak or misconfigured authorization to gain access to view or modify sensitive data | ASSET-C-31 | Shared O-RU | +| T-SharedORU-24 | Data exposure at Shared O-RU | All | Weak confidentiality protection exploited to view sensitive data | ASSET-C-31 | Shared O-RU | +| T-SharedORU-25 | Shared O-RU data exposure at SMO | All | Weak confidentiality protection exploited to view sensitive data | ASSET-C-31 | Shared O-RU | +| T-SharedORU-26 | Shared O-RU data exposure at O-DU | All | Weak confidentiality protection exploited to view sensitive data | ASSET-C-31 | Shared O-RU | +| T-SharedORU-27 | Exposed data in transit between Shared O-RU and O-DU Host/Tenant | All | Weak confidentiality protection exploited to view sensitive data | ASSET-C-31, ASSET-C-24, ASSET-C-25 | Shared O-RU, M-Plane, CUS-Plane | +| T-SharedORU-28 | Exposed data in transit between Shared O-RU and SMO Host/Tenant | All | Weak confidentiality protection exploited to view sensitive data | ASSET-C-31, ASSET-C-22 | Shared O-RU, O1 | +| T-SharedORU-29 | Modify/Delete OFH C-Plane messages | All | Weak integrity protection exploited to modify or delete control messages | ASSET-C-31, ASSET-C_34, ASSET-C-35, ASSET-C-25 | Shared O-RU, O-DU Host, O-DU Tenant, CUS-Plane | +| T-SharedORU-30 | Clock hijacking on OFH S-Plane | All | Weak authorization exploit can also result in spoofing of the Grand Master clock for an availability attack | ASSET-C-31, ASSET-C_34, ASSET-C-35, ASSET-C-25 | Shared O-RU, O-DU Host, O-DU Tenant, CUS-Plane | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|------------------------------------------------|-----------------------------------------------------------------|--------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------| +| T-SharedORU-31 | Parameter conflicts at Shared O-RU | All | Conflicting parameter settings degrade performance or cause an outage. | ASSET-C-31 | Shared O-RU | +| T-SharedORU-32 | Volumetric DDoS attack from O-DU targeting Shared O-RU | All | High-rate of malformed, mis-sequenced, invalid, or valid packets to cause a Denial of Service | ASSET-C-31, ASSET-C-24, ASSET-C-25 | Shared O-RU, M-Plane, CUS-Plane | +| T-SharedORU-33 | Volumetric DDoS attack from SMO targeting Shared O-RU | All | High-rate of malformed, mis-sequenced, invalid, or valid packets to cause a Denial of Service | ASSET-C-31, ASSET-C-22 | Shared O-RU, O1 | +| T-SharedORU-34 | Volumetric DDoS attack targeting O-DU | All | High-rate of malformed, mis-sequenced, invalid, or valid packets to cause a Denial of Service | ASSET-C-34, ASSET-C-35, ASSET-C-24, ASSET-C-25 | O-DU Host, O-DU Tenant, M-Plane, CUS-Plane | +| T-SharedORU-35 | Shared O-RU initialization hijacking by DHCP compromise | All | Compromise DHCP server and use it to prevent Shared O-RU from reaching carrier-active state causing a Denial of Service | ASSET-C-31 | Shared O-RU | +| T-SharedORU-36 | Shared O-RU M-plane hijacking by DNS compromise | All | The name resolution of FQDN can be manipulated by an attacker using a compromised DNS server and prevent Shared O-RU from reaching carrier-active state causing a Denial of Service | ASSET-C-31 | Shared O-RU | +| T-SharedORU-37 | Misconfiguration of MNO Host Role | All | A threat actor could exploit an incorrectly assigned role of Host to control function of the Shared O-RU | ASSET-C-31 | Shared O-RU | +| T-SharedORU-38 | Incorrect Assignment of Spectrum Resources | All | Tenant access to the wrong resources, due to malicious intent or could be exploited to gain access to information. | ASSET-C-31 | Shared O-RU | +| T-SharedORU-39 | Chain of Trust in a Multi-Tenant Environment | All | Untrustworthy certificates can be exploited to gain access to the Shared O-RU | ASSET-C-31, ASSET-C-34, ASSET-C-35, ASSET-C-36, ASSET-C-37, ASSET-C-38, ASSET-C-39 | Shared O-RU, O-DU Host, O-DU Tenant, O-CU Host, O-CU Tenant, SMO Host, SMO Tenant | +| T-SharedORU-40 | Hijack of MNO Host Role | All | Elevation of privilege enables the tenant, acting as host, to have authorized access to sensitive data, credentials, and system privileges | ASSET-C-31 | Shared O-RU | +| T-SharedORU-41 | Not Released Host Role (Host Role resume) | All | Elevation of privilege enables the tenant, acting as host, to have authorized access to sensitive data, credentials, and system privileges | ASSET-C-31 | Shared O-RU | +| T-SharedORU-42 | Misuse of “sudo” privileges | All | Elevation of privilege enables the tenant, acting as host, to have authorized access to sensitive data, credentials, and system privileges | ASSET-C-31 | Shared O-RU | +| T-SharedORU-43 | Eavesdropping of unprotected CUSM-plane data within shared O-RU | All | Eavesdrop sensitive data between neighbor tenants and the host | ASSET-C-31 | Shared O-RU | +| T-SharedORU-44 through T-SharedORU-51 are Void | | | | | | +| T-SharedORU-52 | Thrashing O-DU Failovers | All | Threat actor spoofs SMO to cause O-DU-1 and O-DU-2 to thrash between Active state and Standby state | ASSET-C-34, ASSET-C-22 | O-DU, O1 | +| T-SharedORU-53 | Dual (Dueling) Active O-DUs | All | Threat actor spoofs SMO to cause O-DU-1 and O-DU-2 to both be in Active state. | ASSET-C-34, ASSET-C-22 | O-DU, O1 | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|------------------------|---------------------------------------------------------------------------------|--------------|-----------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------| +| T-SharedORU-54 | Modify/Inject O1 messages at the SMO | All | Threat actor spoofs O-DU to modify, inject, flood O1 messages to the SMO to prevent SMO detection of O-DU failure. | ASSET-C-38, ASSET-C-22 | SMO, O1 | +| T-SharedORU-55 | Set Incorrect Array-Carrier configuration on O-DU (Standby) | All | Threat actor spoofs SMO to set or modify the pre-configured array-carrier configuration on the O-DU in Standby state. | ASSET-C-34, ASSET-C-22 | O-DU, O1 | +| T-SharedORU-56 | Modify Array-Carrier pre-configuration on Shared O-RU | All | Threat actor can gain access to Shared O-RU to modify its pre-configured array-carrier | ASSET-C-31 | Shared O-RU | +| T-SharedORU-57 | Modify/Inject M-Plane messages with Array-Carrier configuration | All | Threat actor Modifies/Injects M-Plane messages with Array-Carrier configuration sent to the Shared O-RU. | ASSET-C-31, ASSET-C-24 | Shared O-RU, M-Plane | +| General threats | | | | | | +| T-GEN-01 | Software flaw attack | All | Vulnerable code exploits, Design Weakness | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-GEN-02 | Malicious access to exposed services using valid accounts | All | Lack of authentication | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-GEN-03 | Untrust binding between the different O-Cloud layers | All | Lack of integrity verification during boot or runtime | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-GEN-04 | Lack of Authentication & Authorization in interfaces between O-Cloud components | All | Lack of authentication, Insecure interfaces | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs, O2 | +| T-GEN-05 | Unsecured credentials and keys | All | Insecure O-Cloud APIs, Lack of integrity verification during boot or runtime | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud | +| T-GEN-06 | Sensitive application data cache exploitation | All | Sensitive information disclosure, Privilege escalation in Applications | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|-----------|--------------------------------------------------------------------|--------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------| +| T-VM-C-01 | Abuse of a privileged VM/Container | All | Misconfiguration or Insecure VM/Container configurations | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-VM-C-02 | VM/Container escape attack | All | Shared tenancy vulnerabilities (multitenant environment), Lack of strong VM/Container isolation, lack of authentication, Insecure networking, Unrestricted communication between VMs/Containers | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-VM-C-03 | VM/Container data theft | All | Lack of authentication, insecure data storage | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-VM-C-04 | VM/Container migration attacks | All | Host misconfiguration, lack of authentication, memory pages copied in clear, vulnerable code exploits | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-VM-C-05 | Changing virtualization resource without authorization | All | Insecure O1/O2 interfaces, Lack of authentication/access control on IMS/DMS | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-VM-C-06 | Failed or incomplete VNF/CNF termination or releasing of resources | All | Lack of authentication, misconfigurations (VNF/CNF, Host OS, Hypervisor/Container Engine) | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-IMG-01 | VM/Container images tampering | All | Compromised VM/Container images (Build machine attacks, Supply chain attacks) at rest, lack of authentication, misconfiguration or Insecure VM/Container images configurations | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs images | +| T-IMG-02 | Insecure channels with images repository | All | Compromised VM/Container images in transit | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs images | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|------------|----------------------------------------------------------------------------------|--------------|-----------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------| +| T-IMG-03 | Secrets disclosure in VM/Container images | All | Secret exposure in VNF/CNF images | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs images | +| T-IMG-04 | Build image on VL | All | Host misconfiguration, lack of authentication | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs images | +| T-VL-01 | VM/Container hyperjacking attack | All | Host misconfiguration, lack of authentication | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-VL-02 | Boot tampering | All | Host misconfigurations, lack of authentication | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-VL-03 | Attack internal network services | All | Insecure O-Cloud APIs, Lack of authentication | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud | +| T-O2-01 | MitM attacks on O2 interface between O-Cloud and SMO | All | Insecure O2 interface, lack authentication | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O2 | +| T-OCAP1-01 | MitM attacks on O-Cloud interface between VNFs/CNFs and the virtualization layer | All | Insecure O-Cloud APIs, lack of authentication | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | +| T-HW-01 | Cross VM/Container side channel attacks | All | Flaws in chip design, use of shared hardware, Lack of isolation, lack of authentication | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud, Apps/VNFs/CNFs | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|------------|---------------------------------------------------------------------------------|--------------|-------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------| +| T-HW-02 | MitM attacks on the interface between virtualization layer and hardware | All | Insecure interfaces between HW and VL layers, lack of authentication, misconfiguration | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | O-Cloud | +| T-ADMIN-01 | Denial of service against NFO/FOCOM | All | Lack of authentication, vulnerable code exploits, design weakness, insecure O2 interface | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | NFO/FOCOM, O-Cloud, Apps/VNFs/CNFs | +| T-ADMIN-02 | Abuse a O-Cloud administration service | All | Lack of authentication, secret exposure (insufficient safeguarding of credentials), vulnerable code exploits, design weakness | ASSET-D-12, ASSET-D-13, ASSET-D-14, ASSET-D-15, ASSET-D-16, ASSET-D-17, ASSET-D-18, ASSET-D-19, ASSET-D-20, ASSET-D-29, ASSET-D-31, ASSET-D-32 | NFO/FOCOM, O-Cloud, Apps/VNFs/CNFs | +| T-AAL-01 | Attacker exploits insecure API to gain access to hardware accelerator resources | All | Insecure AAL APIs and interfaces

    Lack authentication and authorization | ASSET-D-33 to ASSET-D-38 | ASSET-C-29, ASSET-C-30 | +| T-AAL-02 | Internal Overload DoS attack targeting AAL services | All | Insecure AAL APIs and interfaces

    Lack authentication and authorization | ASSET-D-33 to ASSET-D-38 | ASSET-C-29, ASSET-C-30 | +| T-AAL-03 | Fail to clear resources | All | Insecure AAL APIs

    Flaws in AAL design

    Lack of secure deletion of data after process termination | ASSET-D-33 to ASSET-D-38 | ASSET-C-29, ASSET-C-30 | +| T-AAL-04 | HAM compromise | All | Insecure HAM APIs

    Flaws in HAM design

    Lack of access control | ASSET-D-33 to ASSET-D-38 | ASSET-C-29, ASSET-C-30 | +| T-AAL-05 | Malicious memory accesses | All | Insecure AAL APIs

    Flaws in AAL design

    Unrestricted memory access

    Lack of access control | ASSET-D-33 to ASSET-D-38 | ASSET-C-29, ASSET-C-30 | +| T-AAL-06 | Firmware attacks | All | Weak accelerator design | ASSET-D-33 to ASSET-D-38 | ASSET-C-29, ASSET-C-30 | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------|--------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------|---------------------| +| | | | Misconfiguration
    Insecure AAL/HAM APIs | | | +| T-O-CLOUD-ID-01 | ID reuse in O-Cloud's object lifecycle | All | Insufficient data cleanup
    Weak isolation mechanisms
    Inadequate monitoring and Logging
    Lack of ID randomization
    Inefficient access controls
    No Timestamping or Versioning
    Lack of notification mechanisms | ASSET-D-14, ASSET-D-15, ASSET-D-18, ASSET-D-29 | ASSET-C-08 | +| T-O-CLOUD-ID-02 | Node redundancy in O-Cloud deployments | All | Inadequate decommissioning procedures
    Weak identity management
    Insufficient data cleanup
    No state verification
    Lack of Resource Auditing
    Lack of notification mechanisms
    Inadequate monitoring and Logging | ASSET-D-14, ASSET-D-15, ASSET-D-18, ASSET-D-29 | ASSET-C-08 | +| T-O-CLOUD-ID-03 | O-Cloud ID mismanagement | All | Predictable ID Generation
    Lack of ID validation
    Inefficient synchronization
    No ID revocation mechanism
    Inadequate access controls
    Lack of Namespace Segregation | ASSET-D-14, ASSET-D-15, ASSET-D-18, ASSET-D-29 | ASSET-C-08 | +| T-OPENSRC-01 | Developers use SW components with known vulnerabilities and untrusted libraries that can be exploited by an attacker through a backdoor attack | All |
    • Inaccurate inventories of open-source software
    • Lack of consistent Supply Chain traceability and security
    • Lack of coding best practices
    • Modules with known vulnerabilities and untrusted libraries
    | All | All | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|--------------|--------------------------------------------------------------------------------------------------------------------------------------------|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| T-OPENSRC-02 | A trusted developer intentionally inserts a backdoor into an open source code O-RAN component | All | Bugs in open source software caused by mistakes and human error | All | All | +| T-PHYS-01 | An intruder into a site gains physical access to O-RAN components to cause damage or access sensitive data | All except Script kiddies |
    • Improper physical security protection of data centres, PNFs, operation areas, etc.
    • Improper protection to power outages (power supply)
    • Improper protection against environmental disasters
    • Improper maintenance and monitoring of hardware parameters
    • Hardware backdoor
    | All | All | +| T-PHYS-02 | An intruder into the exchange over the Fronthaul cable network attempts to gain electronic access to cause damage or access sensitive data | All except Script kiddies | Physical access to the open Fronthaul cable network | ASSET-D-01, ASSET-D-02, ASSET-D-04, ASSET-D-05 | O-RU, O-DU | +| T-RADIO-01 | Disruption through radio jamming, sniffing and spoofing | All except Script kiddies | Weakness of wireless cellular communications | ASSET-D-06 | UE, O-RU, O-DU | +| T-RADIO-02 | DoS attacks on cognitive radio networks | All except Script kiddies | Weakness of wireless cellular communications | ASSET-D-06 | UE, O-RU, O-DU | +| T-AIML-IM-1 | Training Data Control | All | Vulnerabilities in data sources, vulnerabilities in training database | ASSET-D-25, ASSET-D-26, ASSET-D-27, ASSET-D-28 | Near-RT RIC, Non-RT RIC, xAPPs, rApps | +| T-AIML-IM-2 | Testing Data Control | All | Vulnerabilities in data sources, vulnerabilities in training database | ASSET-D-25, ASSET-D-26, ASSET-D-27, ASSET-D-28 | Near-RT RIC, Non-RT RIC, xAPPs, rApps | +| T-AIML-IM-3 | Label Manipulation | All | Vulnerabilities in data sources, vulnerabilities in training database | ASSET-D-25, ASSET-D-26, ASSET-D-27, ASSET-D-28 | Near-RT RIC, Non-RT RIC, xAPPs, rApps | +| T-AIML-IM-4 | AI/ML Query Exploitation | All | Vulnerabilities in data sources, vulnerabilities in training database, vulnerabilities in AI/ML APIs | ASSET-D-26, ASSET-D-27, ASSET-D-28 | Near-RT RIC, Non-RT RIC, xAPPs, rApps | +| T-AIML-DP-01 | Black-box Data Poisoning | All | Vulnerabilities in data sources, vulnerabilities in training database | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-12, ASSET-C-02, ASSET-C-11 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, xApps, rApps, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-DP-02 | Grey-box Data Poisoning | All | Vulnerabilities in data sources, vulnerabilities in data transport, vulnerabilities in training database | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-12, ASSET-C-02, ASSET-C-11, ASSET-C-22, ASSET-C-14, ASSET-C-40 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, xApps, rApps, Near-RT-RIC SW, Non-RT-RIC SW, O1 interface for streaming data, A1 interface, E2 interface for streaming data | +| T-AIML-DP-03 | White-box Data Poisoning | All | Vulnerabilities in data sources, vulnerabilities in training database | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-12, | Database holding data from xApp applications and E2 Node, Training | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|---------------|--------------------------------------------|--------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | ASSET-C-02, ASSET-C-11, ASSET-C-22, ASSET-C-14, ASSET-C-40 | or test data sets collected externally or internally, Trained ML model, xApps, rApps, Near-RT-RIC SW, Non-RT-RIC SW, O1 interface for streaming data, A1 interface, E2 interface for streaming data | +| T-AIML-MEI-01 | Information Access - Membership Inference | All | Vulnerabilities in data sources, vulnerabilities in training database | ASSET-D-26, ASSET-C-02, ASSET-C-11 | Trained ML model, xApps, rApps, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-MEI-02 | Inference Technique - Membership Inference | All | Vulnerabilities in data sources, vulnerabilities in training database | ASSET-D-26, ASSET-C-02, ASSET-C-11 | Trained ML model, xApps, rApps, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-MEI-03 | Target based - Membership Inference | All | Vulnerabilities in data sources, vulnerabilities in training database | ASSET-D-26, ASSET-C-02, ASSET-C-11 | Trained ML model, xApps, rApps, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-ME-01 | Intellectual Property Theft | All | Vulnerabilities in data sources, vulnerabilities in training database, vulnerabilities in ML model storage, vulnerabilities in ML model transfer | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11 | Database holding data from xApp applications and E2, Training or test data sets collected externally or internally, Trained ML model, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-ME-02 | Data Privacy Violations | All | Vulnerabilities in data sources, vulnerabilities in training database, vulnerabilities in ML model storage, vulnerabilities in ML model transfer | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11 | Database holding data from xApp applications and E2, Training or test data sets collected externally or internally, Trained ML model, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-ME-03 | Adversarial Attacks with Stolen Models | All | Vulnerabilities in data sources, vulnerabilities in training database, vulnerabilities in ML model storage, vulnerabilities in ML model transfer | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11 | Database holding data from xApp applications and E2, Training or test data sets collected externally or internally, Trained ML model, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-MOI-01 | Black-box Model Inversion | All | Model is overfitted, model may have memorized specific training examples, model API not properly protected | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-D-27 | Near-RT RIC, xAPPs, rApps | +| T-AIML-MOI-02 | White-box Model Inversion | All | Model is not protected, training data is not protected, model is overfitted, model may have memorized specific training examples, model API not protected | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-D-27, ASSET-D-28 | Near-RT RIC, Non-RT RIC, xAPPs, rApps | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|--------------|---------------------------------|--------------|-------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| T-AIML-SC-01 | Data Poisoning via Supply Chain | All | Vulnerabilities in data sources, vulnerabilities in training database, vulnerabilities in ML model transfer | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-12 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-SC-02 | Model Tampering | All | Vulnerabilities in ML model transfer | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-12 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-SC-03 | Backdoor via Supply Chain | All | Vulnerabilities in ML model transfer | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-12 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-SC-04 | Hardware Tampering | All | Vulnerabilities in the AI processing HW | ASSET-D-10, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-12 | Database holding data from xApp applications and E2 Node, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-SC-05 | Insecure Maintenance APIs | All | Vulnerabilities in the ML maintenance APIs | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-12 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|--------------|----------------------------------------------|--------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | | (xApps, rApps),Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-SC-06 | Third-party Libraries and Dependencies | All | Vulnerabilities in the ML- related SW | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-12 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps),Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-OI-01 | Denial of Service Impacting Output Integrity | All | Vulnerabilities in data sources, vulnerabilities in training database, vulnerabilities in ML model storage, vulnerabilities in ML model transfer | ASSET-D-25,ASSET-D-26, ASSET-D-27, ASSET-D-07,ASSET-C-12, ASSET-C-02, ASSET-C-11 | Training or test data sets collected externally or internally, Trained ML model, ML prediction results,A1 policies,E2 node data, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-OI-02 | Subscriber QoE Change | All | Vulnerabilities in data sources, vulnerabilities in training database, vulnerabilities in ML model storage, vulnerabilities in ML model transfer. | ASSET-D-25, ASSET-D-26, ASSET-D-27, ASSET-D-07, ASSET-D-11,ASSET-C-02, ASSET-C-02, ASSET-C-11 | Training or test data sets collected externally or internally, Trained ML model , ML prediction results ,Data transported over the O1 interface,A1 policies, E2 node data, Near-RT-RIC SW, Non-RT-RIC SW . | +| T-AIML-MP-01 | Model Parameter Poisoning | All |
    • Insufficient access controls to the model's parameters [i.33]
    • Inadequate monitoring and logging of model's activity [i.32]
    • Lack of control for poisoning in model [i.32]
    • Weak access protection mechanisms for ML model components [i.32]
    | [ASSET-D-26], [ASSET-C-12], [ASSET-D-27] | Near-RT RIC, Non-RT RIC, O-CU, O-DU, xApps, rApps | +| T-AIML-MP-02 | Inference Algorithm Poisoning | All |
    • Insufficient access controls to the model's code [i.33]
    • Inadequate monitoring and logging of model's activity [i.32]
    • Lack of code integrity checking
    • Weak access protection mechanisms for ML model components [i.32]
    | [ASSET-D-26], [ASSET-D-27] | Near-RT RIC, Non-RT RIC, O-CU, O-DU, xApps, rApps | +| T-AIML-MP-03 | Learning Algorithm Poisoning | All |
    • Insufficient access controls to the model's code [i.33]
    • Inadequate monitoring and logging of model's activity [i.32]
    • Weak access protection mechanisms for ML model components [i.32]
    • Lack of code integrity checking
    | [ASSET-C-12] | Near-RT RIC, Non-RT RIC, xApps, rApps | +| T-AIML-MP-04 | Model Control | All | Vulnerabilities in ML model storage, vulnerabilities in ML model transfer | ASSET-D-12, ASSET-D-26, ASSET-D-27, ASSET-D-28 | Near-RT RIC, Non-RT RIC, xAPPs, rApps | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|--------------|-----------------------------------------|--------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| T-AIML-MS-01 | Data Manipulation for Model Skewing | All | Vulnerabilities in (i) training data validation, (ii) less robust model training against cyber-attacks, (iii) less model performance monitoring for monitoring of suspicious activity | ASSET-D-26, ASSET-D-27, ASSET-D-28 | Trained ML model, xApps, rApps, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-MS-02 | Feedback Manipulation for Model Skewing | All | Vulnerabilities in (i) less secure feedback mechanisms to prevent manipulation, (ii) less robust model training against cyber-attacks, (iii) less model performance monitoring for monitoring of suspicious activity | ASSET-D-26, ASSET-D-27, ASSET-D-28 | Trained ML model, xApps, rApps, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-TL-01 | Data Poisoning for Transfer Learning | All | Vulnerabilities in data sources, Vulnerabilities in training database | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-12 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-TL-02 | Model Stealing for Transfer Learning | All | Vulnerabilities in data sources, Vulnerabilities in training database, Vulnerabilities in ML model storage, Vulnerabilities in ML model transfer | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-12 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-TL-03 | Adversarial Examples | All | Vulnerabilities in data sources, Vulnerabilities in training database, Vulnerabilities in ML model storage, Vulnerabilities in ML model transfer | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, Near-RT-RIC SW, Non-RT-RIC SW | +| T-AIML-TL-04 | Backdoor for Transfer Learning | All | Vulnerabilities in ML model transfer | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-12 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, ML components deploying machine learning (xApps, rApps), Near-RT-RIC SW, Non-RT-RIC SW | + +| Threat ID | Threat title | Threat agent | Vulnerability | Threatened Asset | Affected Components | +|--------------|--------------------------------------------------------|--------------|----------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| T-AIML-EL-01 | Model Extraction | All | Vulnerabilities in data sources | ASSET-D-10, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-29, ASSET-30 | Database holding data from xApp applications and E2 Node, Trained ML model, Near-RT-RIC SW, Non-RT-RIC SW, AAL software, Hardware accelerator device firmware | +| T-AIML-EL-02 | Data Inference | All | Vulnerabilities in data sources | ASSET-D-10, ASSET-C-02, ASSET-C-11, ASSET-C-29, ASSET-30 | Database holding data from xApp applications and E2 Node, Near-RT-RIC SW, Non-RT-RIC SW, AAL software, Hardware accelerator device firmware | +| T-AIML-EL-03 | Denial of Service via Side Channels | All | Vulnerabilities in data sources | ASSET-D-10, ASSET-D-26, ASSET-C-02, ASSET-C-11, ASSET-C-29, ASSET-30 | Database holding data from xApp applications and E2 Node, Trained ML model, Near-RT-RIC SW, Non-RT-RIC SW, AAL software, Hardware accelerator device firmware | +| T-AIML-EV-01 | Grey-box based Data Evasion | All | Vulnerabilities in the input APIs of the AI ML model application
    Vulnerabilities in the source of input data used by AI ML for inferences | ASSET-D-10, ASSET-D-25, ASSET-D-26, ASSET-C-02, ASSET-C-11 | Database holding data from xApp applications and E2 Node, Training or test data sets collected externally or internally, Trained ML model, Near-RT-RIC SW, Non-RT-RIC | +| T-E2-01 | Untrusted Near-RT-RIC and E2 Nodes | All | weak mutual authentication | ASSET-C-40 | E2 interface | +| T-E2-02 | Malicious actor monitors messaging across E2 interface | All | Missing or weak confidentiality protection | ASSET-C-40 | E2 interface | +| T-E3-03 | Malicious actor modifies messaging across E2 interface | All | Lack of integrity verification | ASSET-C-40 | E2 interface | +| T-Y1-01 | Untrusted Near-RT-RIC and Y1 consumers | All | weak mutual authentication | ASSET-C-42 | Y1 interface | +| T-Y1-02 | Malicious actor monitors messaging across Y1 interface | All | Missing or weak confidentiality protection | ASSET-C-42 | Y1 interface | +| T-Y1-03 | Malicious actor modifies messaging across Y1 interface | All | Lack of integrity verification | ASSET-C-42 | Y1 interface | + +# --- 8 Security principles + +This clause elucidates security principles that an O-RAN system should achieve. They provide high level and abstract statement of the intended solution to countering potential Threats. Each security principle references applicable ZT tenets. + +## 8.1 Principles (SP) + +### 8.1.1 SP-AUTH Mutual Authentication + +- Mutual authentication SHOULD be established to allow the O-RAN system verifying who performs what, thus possible to detect fake base stations, unauthorized or malicious components, malicious applications and malicious users/administrators. +- ZT Tenets: ZT-1, ZT-2, ZT-3, ZT-4, ZT-6 + +### 8.1.2 SP-ACC Access Control + +- The O-RAN system SHOULD forbid unauthorized administrators or components to access O-RAN resources or services anytime and anywhere. Access controls are required for: + - Network Access Controls for filtering unauthorized/unexpected traffic in the O-RAN components over their interfaces. + - Access controls to restrict access to component configurations. + - Access controls for hardware to maintain the trust chain. +- ZT Tenets: ZT-1, ZT-3, ZT-4, ZT-6 + +### 8.1.3 SP-CRYPTO Secure cryptographic, key management and PKI + +- Well-known, standardized, secure and unbroken cryptographic schemes and protocols SHOULD be used. Proprietary schemes and protocols SHOULD be avoided. +- A secure key management of O-RAN keys (KgNB, KRRC-enc, KRRC-int, KUP-int, and KUP-enc, ksn) SHOULD be implemented to manage all the steps of key lifecycle: key generation using an appropriate level of entropy from a reliable source, secure key storage, key rotation and revocation, secure key destruction, etc. +- Reliable PKI for authentication and data encryption SHOULD be used. Public CAs SHOULD be supported. The certificates SHOULD be issued by a trusted or rooted Certificate Authority (CA). The CA implements the Certificate Policy which specifies the rules and policies about who may or may not receive a Certificate. Relying parties can access the Certificate Policy to determine what validation/verification checks were performed prior to certificate issuance. +- Each O-RU SHOULD be configured with lists of algorithms which are allowed for usage. There SHOULD be one list for integrity algorithms, and one for ciphering algorithms. These lists SHOULD be ordered according to a priority decided by the operator. +- ZT Tenets: ZT-2, ZT-4 + +### 8.1.4 SP-TCOMM Trusted Communication + +- Integrity, confidentiality, availability, authenticity and replay protection of resources SHOULD be ensured in transit (see ‘Critical Assets’, clause 6.3) over O-RAN interfaces. +- ZT Tenets: ZT-1, ZT-2 + +### 8.1.5 SP-SS Secure storage + +- Integrity, confidentiality, availability protection of O-RAN resources SHOULD be ensured at rest (see ‘Critical Assets’, clause 6.3). +- ZT Tenets: ZT-1, ZT-2, ZT-4, ZT-5, ZT-6 + +### 8.1.6 SP-SB Secure boot and self-configuration + +- O-RAN components SHOULD secure their firmware and configuration to provide the opportunity for trust to be extended higher in the software stack. Verified platform firmware can, in turn, verify the operating system (OS) boot loader, which can then verify other software components all the way up to the OS itself, the hypervisor or container runtime layers and O-RAN components. The transitive trust SHOULD be consistent with the concept of the chain of trust (CoT)-a method where each piece of code in the boot process measures and checks the signature of the next stage of the boot process before the software boots. +- The secure boot process, signature verification and self-configuration SHOULD be securely implemented for all O-RAN components to authenticate them before loading. +- ZT Tenets: ZT-1, ZT-3, ZT-4, ZT-5 + +### 8.1.7 SP-UPDT Secure Update + +- A secure update management process SHOULD be implemented for introducing a new component or software change into the O-RAN system. The process SHOULD consider the ability to update the cryptographic algorithms and to adapt to upcoming O-RAN security challenges. A timely update cycles if vulnerabilities are discovered SHOULD be in place. +- ZT Tenets: ZT-1, ZT-5, ZT-7 + +### 8.1.8 SP-RECO Recoverability & Backup + +- A recoverability process to recovery in case of denial of service SHOULD be implemented. An approach for detecting and mitigating DoS attacks SHOULD be in place. +- O-RAN vendors SHOULD define a recovery plan that resets the O-RAN components to a trustworthy state in case of a malfunction or an attack (e.g. DoS). +- Backup systems SHOULD be in place to allow data or component on the O-RAN to be secured. Backup systems SHOULD ensure a suitable level of data or component availability and reliability. +- ZT Tenets: ZT-1, ZT-5, ZT6, ZT-7 + +### 8.1.9 SP-OPNS Security management of risks in open-source components + +- Vendors using open-source code SHOULD enhance its security by applying industry coding best practices. It is recommended that vendors practice a higher level of due diligence for exposure to public exploits when using Open-Source code. +- A Software Bill of Materials (SBOM) SHOULD be maintained to track which open-source components are in use and where. +- Security Analysis (Audit, vulnerability scan, etc.) SHOULD be performed to ensure all identified components are free of security vulnerabilities. +- A proper policy and process SHOULD be in place for identifying and patching known issues with the open-source components. Open-source software components SHOULD be kept up to date and patched. +- ZT Tenets: ZT-1, ZT-4, ZT-5, ZT-6, ZT-7 + +### 8.1.10 SP-ASSU Security Assurance + +- Mobile networks are classified as critical infrastructure making security assurance especially more than relevant: + - Vendors SHOULD ensure and prove that its software or hardware meets 3GPP Security Assurance Specifications (SCAS). + - Vendors SHOULD ensure and prove that its software or hardware fulfils O-RAN security tests, requirements and recommendations provided by O-RAN alliance. + - Vendors SHOULD ensure and prove that their software or hardware meets the needs of many national and international cybersecurity regulations, such as the Cyber Act, GDPR, etc. + - Vendors SHOULD provide risk assessment, secure code review, penetration testing, vulnerability analysis and hardening guidelines for their O-RAN components. +- ZT Tenets: ZT-1, ZT-5, ZT-7 + +### 8.1.11 SP-PRV Privacy + +- In O-RAN, the privacy of end users SHOULD be considered. The privacy of end users can be divided into data privacy, identity privacy and personal information privacy. Most Communication services are to gather data and personal information around end users, which may reveal information sensitive to their privacy. Adversaries would further extract more personal information about end users, such as UE priority, location information, trajectory, and preference. +- ZT Tenets: ZT-1, ZT-2, ZT-3, ZT-4, ZT-5, ZT-6, ZT-7 + +### 8.1.12 SP-SLC Continuous security development, testing, logging, monitoring and vulnerability handling + +- Continuous development and continuous integration (CD/CI) with continuous regression testing and software security auditing SHOULD be implemented. +- Relevant activities events SHOULD be logged and logs collected SHOULD be analyzed in real time for the identification of potential security attacks and for security auditing. +- Continuous monitoring SHOULD be implemented to verify that the wanted security state is maintained throughout the lifecycle of deployed O-RAN components. +- Vulnerability management SHOULD be in place with intelligence to continuously track, identify and remediate vulnerable applications. Vendors SHOULD keep track of any new vulnerabilities discovered and is ready to act on customer product security incidents and reported security issues affecting O-RAN components. +- ZT Tenets: ZT-1, ZT-4, ZT-5, ZT-6, ZT-7 + +### 8.1.13 SP-ISO Robust Isolation + +- In a multi-vendor environment, intra-domain host isolation SHOULD be enforced. In the same host, VMs, CNs, virtualization/container layer, CPU, storage, and network security isolation of resources SHOULD be ensured by implementing system security orchestration, segmentation, lifecycle management, time scheduling, monitoring and audit on the management, signaling, control and data planes, and the execution of virtualized O-RAN components. +- ZT Tenets: ZT-1, ZT-2, ZT-3, ZT-4, ZT-5, ZT-7 + +### 8.1.14 SP-PHY Physical security + +- The O-RAN system SHOULD be located at physically secure environment in a way that minimizes the risk of resource theft and destruction. It SHOULD support secure storage of sensitive data (cryptographic keys and configuration data), execution of sensitive functions (encryption/decryption, authentication), and execution of boot and update processes. +- Special attention SHOULD be paid to the site intrusion and physical access threats against O-RU sites. Consequently O-RU equipment SHOULD disable all unnecessary physical and logical ports, protocols and interfaces. In addition, secure physical connections to O-RU for O&M operations SHOULD be implemented (e.g. secure laptop with secure credentials). +- ZT Tenets: ZT-1, ZT-2, ZT-3, ZT-4, ZT-5, ZT-6, ZT-7 + +### 8.1.15 SP-CLD Secure cloud computing and virtualization + +- Defense methods SHOULD be implemented: virtual machine-based intrusion detection, virtual machine-based isolation, virtual machine-based kernel protection, virtual machine-based access control, and virtual machine-based trusted computing. +- ZT Tenets: ZT-1, ZT-2, ZT-3, ZT-4, ZT-5, ZT-6, ZT-7 + +### 8.1.16 SP-ROB Robustness + +- The O-RAN system SHOULD not only ensure the robustness of software or hardware resources, but also guarantee the robustness of the cognitive radio channel for meeting the QoS of communication services required by users. In some scenarios, the robustness of spectrum sensing SHOULD be enhanced when some sensing nodes (e.g., O-RU) easily malfunction. Robustness is an essential consideration for overcoming the security threats caused by jamming, DoS or DDoS attacks. +- ZT Tenets: ZT-1, ZT-2, ZT-3, ZT-5, ZT-6, ZT-7 + +### 8.1.17 SP-IDM O-Cloud ID secure management + +- To counter threats associated with ID reuse, mismanagement, and redundancy, the O-Cloud should employ robust strategies for ID generation, validation, and lifecycle management. Properly managed IDs reduce risks of data inconsistencies, unauthorized access, and operational inefficiencies. +- ZT Tenets: ZT-1, ZT-3, ZT-4, ZT-5, ZT-6, ZT-7 + +## 8.2 Coverage Threats - Security principles + +The table below illustrates how threats are covered by security principles. It outlines the list of security principles contributing to counter threats. + +Table 8-1 : Coverage Security principles-Threats (1/4) + +| SP | Threats | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +|-----------|------------|------------|------------|------------|------------|------------|------------|------------|------------|-------------|--------------|-------------|-------------|-------------|-------------|-------------|-------------|-------------|-------------|-------------|-------------|-------------|-------------|-------------|-------------|-------------|-------------|----------|--------------|--------------|---------------|--------------|---------------|--------------|---------------|--------------| +| | T-O-RAN-01 | T-O-RAN-02 | T-O-RAN-03 | T-O-RAN-04 | T-O-RAN-05 | T-O-RAN-06 | T-O-RAN-07 | T-O-RAN-08 | T-O-RAN-09 | T-FRHAUL-01 | T-FRHAUL-01A | T-FRHAUL-02 | T-FRHAUL-03 | T-MPLANE-01 | T-MPLANE-02 | T-MPLANE-03 | T-SPLANE-01 | T-SPLANE-02 | T-SPLANE-03 | T-SPLANE-04 | T-SPLANE-05 | T-CPLANE-01 | T-CPLANE-02 | T-UPLANE-01 | T-UPLANE-02 | T-UPLANE-03 | T-UPLANE-04 | T-ORU-01 | T-NEAR-RT-01 | T-NEAR-RT-02 | T-NEAR-RT-02A | T-NEAR-RT-03 | T-NEAR-RT-03A | T-NEAR-RT-04 | T-NEAR-RT-04A | T-NEAR-RT-05 | +| SP-AUTH | | | x | | | x | | | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | x | x | x | x | x | x | x | +| SP-ACC | | | x | | | x | | | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | x | x | x | x | | +| SP-CRYPTO | | x | x | | x | x | | x | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | x | x | x | x | x | x | x | +| SP-TCOMM | | | | | x | | | x | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | x | x | x | x | | +| SP-SS | | | | | | | x | x | | | | | | | | | | | | | | | | x | x | x | x | | | | | x | x | x | x | | +| SP-SB | | x | | | | | | | | | | | | | | | | | | | | | | | | | | | x | x | x | | | | | x | +| SP-UPDT | x | | | | | | | | | | | | | | | | | | | | | | | | | | | | | x | x | | | | | x | +| SP-RECO | | | | x | | | | | x | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| SP-OPNS | | | | | | | | | x | | | | | | | | | | | | | | | | | | | | x | x | x | | | | | x | +| SP-ASSU | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | x | x | x | x | | | | | x | +| SP-PRV | | | | | | | | x | | | | | | | | | | | | | | | | | | | | | x | x | x | x | x | x | x | x | +| SP-SLC | x | | | | | | x | | x | | | | | | | | | | | | | | | | | | | | x | x | x | | | | | x | +| SP-ISO | | x | | | | | | | | | | | | | | | | | | | | | | | | | | | x | x | x | | | | | x | +| SP-PHY | | | | | | | | | x | | | | | | | | | | | | | | | | | | | x | | | | | | | | | +| SP-CLD | | | | | | | | | | | | | | | | | | | | | | | | | | | | | x | x | x | | | | | x | +| SP-ROB | | | | x | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | + +Table 8-2 : Coverage Security principles-Threats (2/4) + +| SP | Threats | | | | | | | | | | | | | | | | | | | | | | +|-----------|---------------|---------------|---------------|-----------|------------|------------|------------|-----------|-----------|-----------|-----------|-----------|-----------|-----------|-----------|-----------|-----------|----------|-----------|----------|----------|----------| +| | T-NONRTRIC-01 | T-NONRTRIC-02 | T-NONRTRIC-03 | T-xAPP-01 | T-xAPP-01A | T-xAPP-01B | T-xAPP-01C | T-xAPP-02 | T-xAPP-03 | T-xAPP-04 | T-rAPP-01 | T-rAPP-02 | T-rAPP-03 | T-rAPP-04 | T-rAPP-05 | T-rAPP-06 | T-rAPP-07 | T-PNF-01 | T-PNF-01A | T-SMO-01 | T-SMO-02 | T-SMO-03 | +| SP-AUTH | x | | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | x | | | +| SP-ACC | x | | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | x | | +| SP-CRYPTO | x | | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | +| SP-TCOMM | | | | | | | | | | x | | | | | | | | | | | | | +| SP-SS | | | | | | | | | | | | | | | | | | | | | | | +| SP-SB | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | +| SP-UPDT | | | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | +| SP-RECO | | | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | x | +| SP-OPNS | | x | x | | | | | | | | | | | | | | | | | | | | +| SP-ASSU | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | +| SP-PRV | | x | x | | | | | | | x | | | | | | | | | | | | | +| SP-SLC | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | +| SP-ISO | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | +| SP-PHY | | | | | | | | | | | | | | | | | | x | x | | | | +| SP-CLD | | x | x | x | x | x | x | x | x | | x | x | x | x | x | x | x | | | | | | +| SP-ROB | | | | | | | | | | | | | | | | | | | | | | | + +Table 8-3 : Coverage Security principles-Threats (3/4) + +| SP | Threats | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +|-----------|----------|----------|----------|----------|----------|----------|-----------|-----------|-----------|-----------|-----------|-----------|----------|----------|----------|----------|---------|---------|---------|---------|------------|---------|---------|------------|------------|----------|----------|----------|----------|----------|----------|-----------------|-----------------|-----------------|--------------|--------------|-----------|-----------|------------|------------|--------------|--------------|--------------| +| | T-GEN-01 | T-GEN-02 | T-GEN-03 | T-GEN-04 | T-GEN-05 | T-GEN-06 | T-VM-C-01 | T-VM-C-02 | T-VM-C-03 | T-VM-C-04 | T-VM-C-05 | T-VM-C-06 | T-IMG-01 | T-IMG-02 | T-IMG-03 | T-IMG-04 | T-VL-01 | T-VL-02 | T-VL-03 | T-O2-01 | T-OCAPI-01 | T-HW-01 | T-HW-02 | T-ADMIN-01 | T-ADMIN-02 | T-AAL-01 | T-AAL-02 | T-AAL-03 | T-AAL-04 | T-AAL-05 | T-AAL-06 | T-O-CLOUD-ID-01 | T-O-CLOUD-ID-02 | T-O-CLOUD-ID-03 | T-OPENSRC-01 | T-OPENSRC-02 | T-PHYS-01 | T-PHYS-02 | T-RADIO-01 | T-RADIO-02 | T-AIML-DP-01 | T-AIML-DP-02 | T-AIML-DP-03 | +| SP-AUTH | x | x | x | x | x | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | | | | | x | x | x | +| SP-ACC | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | | | | | x | x | x | +| SP-CRYPTO | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | | | | | | | | | | | x | x | x | +| SP-TCOMM | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| SP-SS | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | | | | | | | | +| SP-SB | x | x | x | x | x | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | | | | | x | x | x | +| SP-UPDT | x | x | x | x | x | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | x | x | | | | | x | x | x | +| SP-REC | x | x | x | x | x | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | | | | | x | x | x | +| SP-OPNS | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | | | | | x | x | | | | | | | | +| SP-ASSU | x | x | x | x | x | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | x | x | x | x | x | x | x | x | x | +| SP-PRV | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| SP-SLC | x | x | x | x | x | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | x | x | | | | | x | x | x | + +Image: O-RAN Alliance Logo + +O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00 + +| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +|--------|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|--|--|---|---|---|---|---|---| +| SP-ISO | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | x | x | x | x | +| SP-PHY | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | x | x | | | | | +| SP-CLD | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | x | x | x | x | +| SP-ROB | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | x | x | | | +| SP-IDM | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | x | x | x | | | | | | | | | + +Table 8-4 : Coverage Security principles-Threats (4/4) + +| SP | Threats | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +|-----------|---------------|---------------|---------------|--------------|--------------|--------------|-------------|-------------|-------------|-------------|---------------|---------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|--------------|------------|---------|---------|---|--|--| +| | T-AIML-MEI-01 | T-AIML-MEI-02 | T-AIML-MEI-03 | T-AIML-ME-01 | T-AIML-ME-02 | T-AIML-ME-03 | T-AIML-IM-1 | T-AIML-IM-2 | T-AIML-IM-3 | T-AIML-IM-4 | T-AIML-MOI-01 | T-AIML-MOI-02 | T-AIML-SC-01 | T-AIML-SC-02 | T-AIML-SC-03 | T-AIML-SC-04 | T-AIML-SC-05 | T-AIML-SC-06 | T-AIML-OI-01 | T-AIML-OI-02 | T-AIML-MP-01 | T-AIML-MP-02 | T-AIML-MP-03 | T-AIML-MP-04 | T-AIML-MS-01 | T-AIML-MS-02 | T-AIML-TL-01 | T-AIML-TL-02 | T-AIML-TL-03 | T-AIML-TL-04 | T-AIML-EL-01 | T-AIML-EL-02 | T-AIML-EL-03 | T-AIML-EV-01 | T-O-RAN-10 | T-TS-01 | T-A1-04 | | | | +| SP-AUTH | x | x | x | x | x | x | x | x | x | x | | x | x | x | x | x | x | | x | x | x | x | x | x | x | x | x | | x | x | x | x | x | x | x | | x | | | | +| SP-AC | x | x | x | x | x | x | x | x | x | x | | x | x | x | x | x | x | | x | x | x | x | x | x | x | x | x | | x | x | x | x | x | x | x | | x | x | | | +| SP-CRYPTO | x | x | | x | x | x | x | x | x | x | | x | x | x | x | x | x | | x | x | | x | | x | x | x | x | | x | x | x | x | x | x | x | | x | | | | +| SP-TCOM | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | x | | | | +| SP-SS | x | x | x | | | | x | x | x | | | | | | | | | | | x | x | x | | x | x | x | x | | | | | | | | | | | | | | +| SP-SB | x | x | x | x | x | x | | | | | | | x | x | x | x | x | | x | x | x | | | | | x | x | x | x | x | x | x | x | x | x | | x | | | | +| SP-UPDT | x | x | x | x | x | x | | | | | | | x | x | x | x | x | | x | x | x | x | | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | +| SP-RECO | x | x | x | x | x | x | x | x | x | x | | | x | x | x | x | x | | x | x | x | x | | x | x | x | x | x | x | x | x | x | x | x | x | | x | | | | + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 141 + +Image: O-RAN Alliance Logo + +**O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00** + +| SP-OPNS | | | | | | | | | | x | | | | | | | | | x | | x | x | x | x | | | | | | | | | | | | | | | | | | | +|---------|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|--|--|--|--| +| SP-ASSU | x | x | x | x | x | x | | | | x | | | x | x | x | x | x | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | +| SP-PRV | x | x | x | | | | x | x | x | x | x | x | | | | | | | | | x | x | x | x | x | x | | | | | | | | | | | | | | | | | +| SP-SLC | x | x | x | x | x | x | | | | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | +| SP-ISO | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | +| SP-PHY | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| SP-CLD | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | x | x | x | x | x | x | x | x | x | x | x | x | x | | | | | | | +| SP-ROB | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| SP-IDM | | | | | | | | | | | x | x | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 142 + +# 9 Risk assessment + +After identifying the list of assets, threats and vulnerabilities, the next step is the risk assessment. The main concepts of risk assessment are illustrated in the following figure. + +![Figure 9-1: Main concepts of risk assessment. A diagram showing the relationship between Threat, Asset, Vulnerability, Event, Consequence, Likelihood, Treatment, and Risk. Asset is central, connected to Threat, Vulnerability, and Event. Event is connected to Consequence and Likelihood. Consequence and Likelihood are connected to Risk. Treatment is connected to Risk.](e290a22e05f11090af20bf5d49ecfc83_img.jpg) + +``` + +graph TD + Threat[Threat] --- Asset((Asset)) + Vulnerability[Vulnerability] --- Asset + Asset --- Event[Event] + Event --- Consequence[Consequence] + Event --- Likelihood[Likelihood] + Consequence --- Risk[Risk] + Likelihood --- Risk + Treatment[Treatment] --- Risk + +``` + +Figure 9-1: Main concepts of risk assessment. A diagram showing the relationship between Threat, Asset, Vulnerability, Event, Consequence, Likelihood, Treatment, and Risk. Asset is central, connected to Threat, Vulnerability, and Event. Event is connected to Consequence and Likelihood. Consequence and Likelihood are connected to Risk. Treatment is connected to Risk. + +Figure 9-1 : Main concepts of risk assessment + +The criticality of the identified threats in clause 7.4 were assessed based on the severity (consequence) and the likelihood of occurrence. Indications of severity level for each threat are given whether they are considered as high, medium, or low. This severity is a global perception of the risk based on its impacts. In practice, it varies strongly depending on the use cases and deployment/configuration models of the O-RAN system. + +Moreover, the type of loss (availability, integrity and/ or confidentiality) has been assessed for each threat. + +## 9.1 Determination of severity level process + +The process followed to determine the severity level resulting from threats that successfully exploit vulnerabilities is based on Table 9-1 which includes the definition in terms of Privacy, Confidentiality, Integrity, Availability of the three severity levels ‘Low’, ‘Medium’ and ‘High’ shown here as green, yellow and red. + +Table 9-1 defines what “low,” “medium” and “high” means. + +The severity of an impact is expressed as follows: + +- Level of impact for various threats on the properties Privacy, Confidentiality, Integrity, and Availability +- Scale of impact, depending on the number of affected O-RUs and /or O-DUs. +- Scale of impact depending on the Clock Model and Synchronization Topology configurations LLS-C1, LLS-C2, LLS-C3 and LLS-C4 [i.10]. +- Adverse impacts depending on whether or not existing requirements and controls are already defined in the O-RAN requirements specifications. + +Table 9-1 : Severity rating + +| Severity level | Privacy | Confidentiality | Integrity | Availability | Number of affected O-RUs/O-DUs (Only for Threats on O-RU, O-DU, FH interface) | Clock Model and Synchronization Topology configurations (only for Threats on S-PLANE) | Adverse impacts | +|----------------|---------|-----------------|-----------|--------------|-------------------------------------------------------------------------------|---------------------------------------------------------------------------------------|-----------------| +| | | | | | | | | + +| | | | | | | | | +|--------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------|--------------------------------------------------------------|---------------------------------------------------------------------|------------------------------------------------------|----------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Low | Disclosure of personal data which, with aggregation or processing, is unlikely to reveal unique subscriber's identity. | Disclosure of information for internal use. No specific impact on its disclosure | Minor/Unnoticeable effect on system behavior/output | Brief Interruption in operations.
    (Estimated in secs/mins/hours) | One O-DU is affected with its related O-RU | DoS attacks on LLS-C2

    DoS attacks on LLS-C4 | Already existing requirements and controls are defined in the O-RAN specifications to prevent, or at least significantly impede, the vulnerability from being exercised. Existing requirements and controls are only efficient to protect from both internal and external threats. | +| Medium | Disclosure of personal data (according to GDPR) which CAN be processed or aggregated to uniquely identify subscribers.

    NOTE: Personal data in GDPR means any information relating to an identified or identifiable natural person ('data subject'); an identifiable natural person is one who can be identified, directly or indirectly, in particular by reference to an identifier such as a name, an identification number, location data, an online identifier or to one or more factors specific to the physical, physiological, genetic, mental, economic, cultural or social identity of that natural person. | Disclosure of privileged information Access credentials/ configuration data, etc. | Alteration of some system functionality and features/output. | Short-term Interruption in operations.
    (Estimated in hours/Days) | One O-DU is affected with its related multiple O-RUs | DoS attacks on LLS-C1 | Already existing requirements and controls are defined in the O-RAN specifications to prevent, or at least significantly impede, the vulnerability from being exercised. Existing requirements and controls are only efficient to protect from external threats. | +| High | Disclosure of sensitive personal data (GDPR special category).

    NOTE: Special data category in GDPR: data revealing racial or ethnic origin, political opinions, religious or philosophical beliefs, or trade union membership, and the processing of genetic data, | Disclosure of high value information, trade secrets, IP, mission critical data, master-keys, etc. | Complete change in normal System functioning | Prolonged interruption of operations.
    (Estimated in days/Weeks) | Several O-DUs and O-RUs are affected | DoS attacks on LLS-C3 | No existing requirements and controls in the ORAN specifications yet to protect from internal and/or external threats | + +| | | | | | | | | +|--------------------------------------------------------------------------------------------------------------------------------------------------------|--|--|--|--|--|--|--| +| biometric data for uniquely identifying a natural person, data concerning health or data concerning a natural person's sex life or sexual orientation. | | | | | | | | +|--------------------------------------------------------------------------------------------------------------------------------------------------------|--|--|--|--|--|--|--| + +**NOTE 1:** The severity level depends on the number of affected RUs and O-DUs. The severity level is consequently 'Low' in case of one affected O-RU, 'Medium' in case of one affected O-DU with its related multiple O-RUs, and 'High' for multiple affected O-DUs-O-RUs. Operators conducting a full risk analysis according to this report should conduct a use case-based analysis taking into account the likelihood and the real deployment of the O-RAN system. + +**NOTE 2:** + +### Configuration LLS-C1 + +In LLS-C1, the network timing is distributed from O-DU to O-RU via direct connection between O-DU site and O-RU site. O-DU is acting as a master and directly synchronizes O-RU. + +- DoS attacks against the master clock: There are two scenarios: + 1. Scenario 1: One O-RU is served by O-DU, therefore only one O-RU is affected. Consequently, the severity level is 'Low'. + 2. Scenario 2: Multiple O-RUs are served by O-DU, therefore all those O-RUs are affected as the connection between O-DU and O-RU is point-to-point. Consequently, the severity level is 'Low'. + +### Configuration LLS-C2 + +In LLS-C2, the network timing is distributed from O-DU to O-RU between O-DU sites and O-RU sites. One or more Ethernet switches are allowed in the fronthaul network. O-DU acting as master to distribute network timing toward O-RU. + +- DoS attacks against the master clock within the O-DU may affect one or multiple O-RUs. In this configuration, a neighbor O-DU could act a backup and play the role of a master to distribute network timing to all the RUs belonging to the affected O-DU by reconfiguring the network of switches. Consequently, the severity level is 'Low'. + +### Configuration LLS-C3 + +Frequency and time distribution is made by the fronthaul network itself (not by the O-DU). One or more PRTC/T-GM are implemented in the fronthaul network to distribute network timing toward O-DU and O-RU. + +- DoS attacks against the master clock within the fronthaul network may affect multiple O-DUs with their related O-RUs. Consequently, the severity level is 'High'. + +### Configuration LLS-C4 + +Local PRTC timing that provides time synchronization to the O-RU (it could be embedded in the O-RU). + +- DoS attacks against the master clock may affect only one O-RU. Consequently, the severity level is 'Low'. + +According to what we described in the here above two notes, T-SPLANE-01 has been split in Table 9-4 according to the Clock Model and Synchronization Topology configurations C1, C2, C3, and C4. + +**NOTE:** Adverse impacts: This factor depends on the normative O-RAN security requirements in the security requirements specification. For a threat without any requirement in front of it, the adverse impacts level is High. It is Medium or Low for a threat with related security requirements (see column 'Assuptions') helping in reducing its impact. + +## 9.2 Determination of likelihood level process + +The process followed to determine the likelihood level resulting from threats that successfully exploit vulnerabilities is based on Table 9-2 which includes the relevant factors that are considered. For each factor, three levels ‘Low’, ‘Medium’ and ‘High’ are shown in Table 9-2 as green, yellow and red. + +Table 9-2 defines what “low,” “medium” and “high” means. + +The likelihood level is expressed by four factors as follows: + +- **Adverse impacts:** This factor depends on the existing normative O-RAN security requirements and controls. For example, the level is high in case no available O-RAN security requirements and controls in the O-RAN security specifications. In the risk assessment Table 9-4 in the column ‘Assumptions’, some of the agreed security controls by the O-RAN alliance have been stated for some threats as arguments for justifying the likelihood levels ‘Low’ or ‘Medium’. This means that the likelihood level is estimated at ‘Low’ or ‘Medium’, provided that the security controls are in place. + +**NOTE:** This factor is used to determine the likelihood level for the most categories of threats. It is also used as a relevant factor for severity for some categories of threats, in particular the O-Cloud threats category. + +- **Threat event initiation:** This factor takes into consideration the capabilities that attackers possess and the potential entry points to exploit a vulnerability and initiate an attack. For example, it is high if an attack can be initiated from internet or untrusted network. +- **Exposure:** This factor is related to the number of external interfaces and/or services that are exposed to an attacker. +- **Zero Trust Approach:** Likelihood scoring considers a zero-trust architecture which protects against internal threat actors. Likelihood scores are higher for a zero-trust architecture (ZTA) because internal threats should be considered in addition to external threats. In a ZTA it cannot be assumed that perimeter defense is sufficient. As a result, scored Likelihood = Medium, at a minimum. Reconnaissance type attacks can be scored Likelihood = High while damaging/availability attacks can be scored Likelihood = Medium. The reason is that threat actors are less likely to perform damaging attacks that are quickly and easily detected. Advanced Persistent Threats (APTs) typically move laterally in anonymous fashion to prevent detection while providing reconnaissance (see O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00). + +**Table 9-2 : Likelihood rating** + +| Scale | Factors | Measure of Likelihood | +|---------------|---------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| High | Adverse impacts | No existing requirements and controls in the ORAN specifications yet to protect from internal and/or external threats | +| | Threat event initiation | Attack can be launched from the internet or untrusted network | +| | Exposure | System has a large amount of exposed interfaces (e.g. ORAN interfaces, multiple O-DU, multiple O-RU, multi administrators/customers) | +| | ZTA | Reconnaissance type attacks | +| | Open-source/COTS support |
    • • No vulnerability handling and patch management in place: Several CVE have already been discovered; no regular patches provided to fix the detected vulnerabilities
    • • Use of open-source module not supported by a broader community
    • • Use of non popular COTS product
    | +| Medium | Adverse impacts | Already existing requirements and controls are defined in the O-RAN specifications to prevent, or at least significantly impede, the vulnerability from being exercised. Existing requirements and controls are only efficient to protect from external threats. | +| | Threat event initiation | Malicious user needs to have direct access to the target system | +| | Exposure | System has a medium amount of exposed interfaces (e.g. ORAN interfaces, one O-DU, multiple O-RU) | + +| | | | +|-----|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | ZTA | Damaging/availability type attacks | +| | Open-source/COTS support |
    • Vulnerability handling and patch management in place but not efficient: Several CVE have already been discovered; no timely patches provided to fix the discovered vulnerabilities
    • Use of open-source module moderately supported by a broader community
    | +| Low | Adverse impacts | Already existing requirements and controls are defined in the O-RAN specifications to prevent, or at least significantly impede, the vulnerability from being exercised. Existing requirements and controls are only efficient to protect from both internal and external threats. | +| | Threat event initiation | The malicious user needs to have administrative or elevated privileges in the target system (external having internal privileges or internal having internal privileges) | +| | Exposure | Slightly exposed to external systems (e.g. one O-DU, one O-RU) (least privilege approach) | +| | ZTA | Perimeter defenses are sufficient. No potential for internal threats | +| | Open-source/COTS support |
    • Component supporting open-source module: a broader community is investing in
    • COTS modules are popular and widely used in critical infrastructure
    | + +## 9.3 Evaluation of the risks process + +The following risk assessment matrix is used to assess the risk score. The matrix takes as input two estimated qualitative inputs: (i) likelihood and (ii) the severity. One axis representing the probability of a risk scenario occurring and the other representing the damage it will cause (Severity). In the middle, you have scores based on their combined totals. + +Using this formula $RISK = Severity \times Likelihood$ by a simple multiply the severity and likelihood scores to obtain the final risk score as shown in Table 9-3. + +For example, if the estimated likelihood of a threat is low and the corresponding severity is high, then the risk is medium. + +**Table 9-3 : Risk assessment matrix** + +| | | | | | +|------------|----------|----------|----------|----------| +| Severity | 3-High | 3-Medium | 6-High | 9-High | +| | 2-Medium | 2-Low | 4-Medium | 6-High | +| | 1-Low | 1-Low | 2-Low | 3-Medium | +| | | 1-Low | 2-Medium | 3-High | +| Likelihood | | | | | + +## 9.4 Risk assessment output + +The following is the risk assessment output table which illustrates the different threats along with their impacts, the type of loss, the perceived severity/likelihood levels and the risk scoring. + +Table 9-4 : Risk Assessment + +| THREAT ID | RISK DESCRIPTION | IMPACT DESCRIPTION | CIA | SEVERITY LEVEL | Likelihood LEVEL | Applied factors | Rationale | Considered Assumptions | Risk Score | +|-------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|----------------|------------------|-----------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------|------------| +| T-O-RAN-01(NEAR RT RIC) | An attacker exploits insecure designs or lack of adoption of security controls (e.g. hardening) in O-RAN components causing:
    - Loss of service
    - Privacy issues
    - Performance issues in the system in O-RAN components | Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data | C, I, A | High | High |
    • Exposure (High): A1, O1, E2, xApps, rApps
    • Adverse impacts (High)
    |

    O-Cloud security hardening requirements have not been specified yet and it is unclear whether the industry practices sufficiently cover the threats outlined.

    O-RAN Alliance has specified security for O-RAN interfaces at the transport layers thereby mitigating access to O-RAN functions through the interfaces. The O-RAN Alliance has not yet specified security for protecting the platforms that host the O-RAN functions from physical or remote access.

    | | High | +| T-O-RAN-01 (Non RT RIC + SMO) | An attacker exploits insecure designs or lack of adoption of security controls (e.g. hardening) in O-RAN components causing:
    - Loss of service
    - Privacy issues
    - Performance issues in the system in O-RAN components | Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data | C, I, A | High | High |
    • Exposure (High): A1, O1, O2, rApps
    • Adverse impacts (High)
    |

    O-Cloud security hardening requirements have not been specified yet and it is unclear whether the industry practices sufficiently cover the threats outlined.

    O-RAN Alliance has specified security for O-RAN interfaces at the transport layers thereby mitigating access to O-RAN functions through the interfaces. The O-RAN Alliance has not yet specified security for protecting the platforms that host the O-RAN functions from physical or remote access.

    | | High | + +| | | | | | | | | | +|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|------|------|--------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| T-O-RAN-01
    (O-CU) | An attacker exploits insecure designs or lack of adoption of security controls (e.g. hardening) in O-RAN components causing:
    - Loss of service
    - Privacy issues
    - Performance issues in the system in O-RAN components | Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data | C, I, A | High | High |
    • Exposure (High): O1, E2, administration interfaces
    • Adverse impacts (High)
    |

    O-Cloud security hardening requirements have not been specified yet and it is unclear whether the industry practices sufficiently cover the threats outlined.

    O-RAN Alliance has specified security for O-RAN interfaces at the transport layers thereby mitigating access to O-RAN functions through the interfaces. The O-RAN Alliance has not yet specified security for protecting the platforms that host the O-RAN functions from physical or remote access.

    | High | +| T-O-RAN-01
    (O-DU) | An attacker exploits insecure designs or lack of adoption of security controls (e.g. hardening) in O-RAN components causing:
    - Loss of service
    - Privacy issues
    - Performance issues in the system in O-RAN components | Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data | C, I, A | High | High |
    • Exposure (High): E2, O1, FH
    • Adverse impacts (High)
    |

    O-Cloud security hardening requirements have not been specified yet and it is unclear whether the industry practices sufficiently cover the threats outlined.

    O-RAN Alliance has specified security for O-RAN interfaces at the transport layers thereby mitigating access to O-RAN functions through the interfaces. The O-RAN Alliance has not yet specified security for protecting the platforms that host the O-RAN functions from physical or remote access.

    | High | +| T-O-RAN-01
    (O-RU) | An attacker exploits insecure designs or lack of adoption of security controls (e.g. hardening) in O-RAN components causing:
    - Loss of service
    - Privacy issues
    - Performance issues in the system in O-RAN components | Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data | C, I, A | High | High |
    • Exposure (High): FH, O1, physical
    • Adverse impacts (High)
    |

    O-Cloud security hardening requirements have not been specified yet and it is unclear whether the industry practices sufficiently cover the threats outlined.

    O-RAN Alliance has specified security for O-RAN interfaces at the transport layers thereby mitigating access to O-RAN functions through the interfaces. The O-RAN Alliance has not yet specified security for protecting the platforms that host the O-RAN

    | High | + +| | | | | | | | | | | +|------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------|--------|----------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------|------| +| | | | | | | | functions from physical or remote access. | | | +| T-O-RAN-02 | An attacker exploits misconfigured or poorly configured O-RAN components causing:
    - Loss of service
    - Privacy issues
    - Performance issues in the system | Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data | C, I, A | High | High |
    • Threat event initiation (High)
    • Adverse impacts (High)
    | O-Cloud security hardening requirements have not been specified yet and it is unclear whether the industry practices sufficiently cover the threats outlined. | | High | +| T-O-RAN-03 | Attacks from the internet exploit weak authentication and access control to penetrate O-RAN network boundary, causing:
    - Flooding of the network
    - loss of service, performance issues
    - Unauthorized access to ORAN components | Denial of service for component access and/or function/service offered;
    Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data; | C, I, A | High | Medium |
    • Threat event initiation (High)
    • Adverse impacts (Medium)
    | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for xApps yet. This attack to be performed requires multiple steps to be achieved by an attacker. | The O-RAN network elements should not be exposed to untrusted/ internet end points without network access control. | High | +| T-O-RAN-04 | An attacker attempts to flooding the airlink signal (legitimate communications) through IoT devices causing:
    - Loss of service | Denial of service for component access and/or function/service offered | A | Medium | High |
    • Threat event initiation (High)
    • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any security measures on flooding attacks through IoT devices. | | High | +| T-O-RAN-05 | An attacker penetrates and compromises the O-RAN system through the open O-RAN's Fronthaul, O1, O2, A1, and E2 | Data tampering and information disclosure;
    Denial of service from within for component access and/or function/service offered;
    Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data; | C, I, A | High | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (Medium)
    | Existing controls are in place (moderately satisfactory). Malicious user needs to have direct (physical) access to the target system | | High | + +| | | | | | | | | | | +|-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------|--------|--------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------|--------| +| T-O-RAN-06 | An attacker exploits insufficient/improper mechanisms for authentication and authorization to compromise O-RAN components | Unauthenticated/unauthorized access of the O-RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data | C, I, A | High | High |
    • Threat event initiation (High)
    • Adverse impacts (Medium)
    | Existing controls are in place (moderately satisfactory), Attack can be launched from the internet or untrusted network | Authentication procedures are in place | High | +| T-O-RAN-07 | An attacker compromises O-RAN monitoring mechanisms and log files integrity and availability | Compromise of availability and integrity of security event log files could conduct to delays, wrong audit results, delays in security restoration, threats persistence. | I, A | Medium | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (Medium)
    | Existing controls are in place (moderately satisfactory), Malicious user needs to have administrative or elevated privileges in the target system. It is a likely scenario after initial compromise of network elements. | Authentication procedures, patch management regular programmed update, vulnerability handling/regular scanning, SBOM are in place | Medium | +| T-O-RAN-08 | An attacker compromises O-RAN data integrity, confidentiality and traceability | An attacker could, in such case, data tampering, information disclosure, spoofing identity, elevation of privilege, etc. | C, I | Medium | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (Medium)
    | Existing controls are in place (moderately satisfactory). Likely scenario after initial compromise of network elements with local data storage. | Protection at rest (e.g. HSM) is in place (operator decision), | Medium | +| T-O-RAN-09 | An attacker compromises O-RAN components integrity and availability | An attacker could, in such case, cause denial-of-service, data tampering, information disclosure, spoofing identity, etc. | I, A | High | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (Medium)
    | Existing controls are in place (moderately satisfactory), Malicious user needs to have direct access to the target system | | High | +| T-ORAN-10 | A successful attack could:
    -compromise confidentiality, integrity and availability due to the prolonged undetected presence of an attacker in the network | confidentiality, integrity, availability | CIA | High | High |
    • Impact on confidentiality, integrity and availability (High)
    • Threat event initiation (High)
    |
    • Impact on confidentiality, integrity, and availability (High): fragmented logs lead to undetected breaches, tampering, and delayed responses, causing significant data loss, integrity issues, and system disruptions.
    • Threat event initiation (High): Adversary behaviour generally goes undiscovered.
    | | High | +| T-FRHAUL-01 | An attacker penetrates O-DU and beyond through O-RU (bidding-down attack) | Data tampering and information disclosure; | C, I | High | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (Medium)
    • Exposure (Medium)
    | System has an amount of exposed interfaces: multiple O-DU, multiple O-RU, FH interface. It is a possible attack, however needs physical access and sophistication to execute | | High | + +| | | | | | | | | | | +|------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------|--------|--------|-------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------|--------| +| T-FRHAUL-01A | An attacker penetrates O-DU and beyond through O-RU (bidding-down attack) | Spoofing | C, I | High | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (Medium)
    • Exposure (Medium)
    | System has an amount of exposed interfaces: multiple O-DU, multiple O-RU, FH interface. It is a possible attack, however needs physical access and sophistication to execute | | High | +| T-FRHAUL-02 | Unauthorized access to the Open Front Haul Ethernet L1 physical layer interface (cables and connections) | It provides a means to launch attacks on the confidentiality of the Open Front Haul system. | C | High | Low |
    • Threat event initiation (Low)
    • Adverse impacts (High)
    | It is a possible attack, however needs physical access and sophistication to execute | | Medium | +| T-FRHAUL-03 | Unauthorized access to the Open Front Haul Ethernet L1 physical layer interface (cables and connections) | It provides a means to launch attacks on the availability of the Open Front Haul system. | A | High | Low |
    • Threat event initiation (Low)
    • Adverse impacts (High)
    | It is a possible attack, however needs physical access and sophistication to execute | | Medium | +| T-MPLANE-01 | An attacker attempts to intercept the Fronthaul (MITM) over M Plane to obtain protected information | Passive wiretapping | C | Medium | Low |
    • Threat event initiation (Low)
    • Adverse impacts (Medium)
    | It is a possible attack, however needs physical access and sophistication to execute | TLS with PKI is supported, it is up to MNO, the likelihood is low provided that MNOs use TLS over the M-Plane | Low | +| T-MPLANE-02 | An attacker attempts to intercept the Fronthaul (MITM) over M Plane to alter m-plane data | Intercepting and modifying of the M plane messages. | I | Medium | Low |
    • Threat event initiation (Low)
    • Adverse impacts (Medium)
    | It is a possible attack, however needs physical access and sophistication to execute | TLS with PKI is supported, it is up to MNO, the likelihood is low provided that MNOs use TLS over the M-Plane | Low | +| T-MPLANE-03 | An attacker attempts to intercept the Fronthaul (MITM) over M Plane to disrupt services | Denial of service | A | Medium | Low |
    • Threat event initiation (Low)
    • Adverse impacts (Medium)
    | It is a possible attack, however needs physical access and sophistication to execute | TLS with PKI is supported, it is up to MNO, the likelihood is low provided that MNOs use TLS over the M-Plane | Low | +| T-SPLANE-01-C1 (one O-RU scenario) | DoS attack on an O-DU acting as master to distribute network timing toward O-RU based on point-to-point connection in LLS-C1. In this scenario, only one O-RU is connected to O-DU, | This attack may cause performance degradation or interruption of services to only one O-RU that rely on accurate time from the affected O-DU. The severity level is consequently 'Low'. | A | Low | Low |
    • Exposure (Low)
    • Threat event initiation (Medium)
    | Slightly exposed to external systems: one O-RU. It is a possible attack, however needs physical access and sophistication to execute | Access control on the CUSM-Plane that mitigates unauthorized access by an insider are in place. 802.1x | Low | + +| | | | | | | | | | | +|------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---|--------|--------|-------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------| +| | therefore only that O-RU is affected. | | | | | | | protocol is supported it can reduce the likelihood of this attack. | | +| T-SPLANE-01-C1 (multiple O-RUs scenario) | DoS attack on an O-DU acting as master to distribute network timing toward O-RU based on point-to-point connection in LLS-C1. In this scenario, multiple O-RUs are connected to O-DU, therefore those O-RUs are affected. | This attack may cause performance degradation or interruption of services to all the RUs that rely on accurate time from the affected O-DU. The severity level is consequently 'Medium'. | A | Medium | Medium |
    • • Exposure (Medium)
    • • Threat event initiation (Medium)
    | System has a medium amount of exposed interfaces: multiple O-RUs. It is possible attack, however needs physical access and sophistication to execute | | Medium | +| T-SPLANE-01-C2 | DoS attack on an O-DU acting as master to distribute network timing toward O-RU in LLS-C2. One or more Ethernet switches are allowed between the central site (hosting O-DUs) and the remote sites (hosting O-RUs). | This attack may cause performance degradation or interruption of services to all the RUs that rely on accurate time from the affected O-DU. In this configuration, a neighbor O-DU could act a backup and play the role of a master to distribute network timing to all the RUs belonging to the affected O-DU by reconfiguring the network of switches. The severity level is consequently 'Low'. | A | Low | Medium |
    • • Exposure (Medium)
    • • Threat event initiation (Medium)
    | System has a medium amount of exposed interfaces. It is a possible attack, however needs physical access and sophistication to execute | Access control on the CUSM-Plane that mitigates unauthorized access by an insider are in place. 802.1x protocol is supported it can reduce the likelihood of this attack. | Low | +| T-SPLANE-01-C3 | DoS attack against a Master clock in the LLS-C3 configuration | In this configuration, the frequency and timing distribution is made by the fronthaul network (not by O-DU). DoS attack against a master clock may cause performance degradation or interruption of services to all the RUs and DUs that rely on accurate time from the affected master clock in the fronthaul network. The severity level is consequently 'High'. | A | High | Medium |
    • • Exposure (Medium)
    • • Threat event initiation (Medium)
    | System has a medium amount of exposed interfaces. It is a possible attack, however needs physical access and sophistication to execute | | High | +| T-SPLANE-01-C4 | DoS attack against a Master clock in the LLS-C4 configuration | In this configuration, the time source could be locally embedded in the RU itself. DoS attack in the time source may cause performance degradation or interruption of services to only one O-RU where the time source is embedded. The severity level is consequently 'Low'. | A | Low | Low |
    • • Exposure (Low)
    • • Threat event initiation (Medium)
    | Slightly exposed to external systems: one O-RU. It is a possible attack, however needs physical access and sophistication to execute | Access control on the CUSM-Plane that mitigates unauthorized access by an insider are in place. 802.1x protocol is supported it can reduce the likelihood of this attack. | Low | + +| | | | | | | | | | | +|-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---|------|--------|----------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------| +| T-SPLANE-02 | Impersonation of a Master clock (Spoofing) within a PTP network with a fake ANNOUNCE messages | Degradation in the accuracy of time may cause DoS to applications on all the RUs that rely on accurate time, potentially bringing down the cell.
    A cell outage caused by misaligned time, may further impact performance in connected neighboring cells. | A | High | Low |
    • Threat event initiation (Medium)
    • Adverse impacts (Low)
    | Existing controls are in place to prevent, or at least significantly impede, the vulnerability from being exercised. It is a possible attack, however needs physical access and sophistication to execute | Access control on the CUSM-Plane that mitigates unauthorized access by an insider are in place. 802.1x protocol is supported it can reduce the likelihood of this attack. | Medium | +| T-SPLANE-03 | A Rogue PTP Instance wanting to be a Grand Master by sending manipulated/malicious ANNOUNCE messages declaring him to be the best clock in the network | Degradation in the accuracy of time may cause DoS to applications on all the RUs that rely on accurate time, potentially bringing down the cell.
    A cell outage caused by misaligned time, may further impact performance in connected neighboring cells. | A | High | Low |
    • Threat event initiation (Medium)
    • Adverse impacts (Low)
    | Existing controls are in place to prevent, or at least significantly impede, the vulnerability from being exercised. It is a possible attack, however needs physical access and sophistication to execute | Access control on the CUSM-Plane that mitigates unauthorized access by an insider are in place. 802.1x protocol is supported it can reduce the likelihood of this attack. | Medium | +| T-SPLANE-04 | Selective interception and removal of PTP timing packets | Clock degradation in attacked nodes. Removing all packets or random packets may push the clocks in attacked nodes into free running mode. Degradation in the accuracy of time may cause DoS to applications on all the RUs that rely on accurate time, potentially bringing down the cell.
    A cell outage caused by misaligned time, may further impact performance in connected neighboring cells. | A | High | Low |
    • Threat event initiation (Medium)
    • Adverse impacts (Low)
    | Existing controls are in place to prevent, or at least significantly impede, the vulnerability from being exercised. It is a possible attack, however needs physical access and sophistication to execute | Access control on the CUSM-Plane that mitigates unauthorized access by an insider are in place. 802.1x protocol is supported it can reduce the likelihood of this attack. | Medium | +| T-SPLANE-05 | Packet delay manipulation attack | Degradation in the accuracy of time may cause DoS to applications on all the RUs that rely on accurate time, potentially bringing down the cell.
    A cell outage caused by misaligned time, may further impact performance in connected neighboring cells. | A | High | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (Medium)
    | Existing controls are in place to prevent (moderately satisfactory). It is a possible attack, however needs physical access and sophistication to execute | 802.1x protocol is supported it can reduce the likelihood of this attack. | High | + +| | | | | | | | | | | +|-------------|-----------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---|--------|-----|-------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| T-CPLANE-01 | Spoofing of DL C-plane messages | The lack of authentication could allow an adversary to inject own DL C-plane messages that falsely claiming to be from the associated O-DU.
    As a result, it would block the O-RU to process the corresponding U-Plane packets, leading to temporarily DoS. (dropping the entire DL C-plane messages would achieve same goal) | A | Medium | Low |
    • Threat event initiation (Medium)
    • Adverse impacts (Low)
    | Existing controls are in place to prevent, or at least significantly impede, the vulnerability from being exercised. It is a possible attack, however needs physical access and sophistication to execute | 802.1x at the ethernet level ensures authentication and authorization for communication over FH interface, not sure that this control reduce the risk of spoofing of c-plane at a low level. Mitigations related to monitoring and configuration of network nodes are in place | Low | +| T-CPLANE-02 | Spoofing of UL C-plane messages | The lack of authentication could allow an adversary to inject own UL C-plane messages that falsely claiming to be from the associated O-DU.
    As a result, temporarily limited cell performance (or even DoS) on cells served by the O-RU and in addition a consequential threat to all O-RUs parented to that O-DU might exist. (dropping the entire UL C-plane messages would achieve same goal) | A | Medium | Low |
    • Threat event initiation (Medium)
    • Adverse impacts (Low)
    | Existing controls are in place to prevent, or at least significantly impede, the vulnerability from being exercised. It is a possible attack, however needs physical access and sophistication to execute | 802.1x at the ethernet level ensures authentication and authorization for communication over FH interface, not sure that this control reduce the risk of spoofing of c-plane at a low level. Mitigations related to monitoring and configuration of network nodes are in place | Low | +| T-UPLANE-01 | An attacker attempts to intercept the Fronthaul (MITM) over U Plane to obtain user data (PDCP protocol is used) | For the transported U-Plane data an attacker could potentially do threats, such as passive wiretapping, but would need to break PDCP Security prior to any content access. | C | Medium | Low |
    • Threat event initiation (Low)
    • Adverse impacts (Medium)
    | Existing controls are in place to prevent, or at least significantly impede, the vulnerability from being exercised. It is a possible attack, however, needs physical access and sophistication to execute | 802.1x protocol is supported it can reduce the likelihood of this attack. | Low | +| T-UPLANE-02 | An attacker attempts to intercept the Fronthaul (MITM) over U Plane to | For the transported U-Plane data an attacker could potentially do threats, such as passive | I | Medium | Low |
    • Threat event initiation (Low)
    | Existing controls are in place to prevent, or at least significantly impede, the vulnerability from | 802.1x protocol is supported it can reduce the | Low | + +| | | | | | | | | | | +|--------------|-----------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------|--------|--------|-----------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------|--------| +| | modify u-plane data (PDCP protocol is used) | wiretapping, but would need to break PDCP Security prior to any content access. | | | | • Adverse impacts (Medium) | being exercised. It is a possible attack, however, needs physical access and sophistication to execute | likelihood of this attack. | | +| T-UPLANE-03 | An attacker attempts to intercept the Fronthaul (MITM) over U Plane to disrupt services (PDCP protocol is used) | For the transported U-Plane data an attacker could potentially do threats, such as passive wiretapping, but would need to break PDCP Security prior to any content access. | A | Medium | Low | • Threat event initiation (Low)
    • Adverse impacts (Medium) | Existing controls are in place to prevent, or at least significantly impede, the vulnerability from being exercised. It is a possible attack, however, needs physical access and sophistication to execute | 802.1x protocol is supported it can reduce the likelihood of this attack. | Low | +| T-UPLANE-04 | Spoofing and unauthorized access of U-Plane data packets | An attacker could degrade service quality, disrupt legitimate data flow, and potentially cause a DoS. | NA | Medium | Low | • Threat event initiation (Low)
    • Adverse impacts (Medium) | Existing controls are in place to prevent, or at least significantly impede, the vulnerability from being exercised. It is a possible attack, however, needs physical access and sophistication to execute | 802.1x protocol is supported it can reduce the likelihood of this attack. | Low | +| T-ORU-01-a | An attacker stands up a rogue O-RU (standalone) - a false base station | This opens the door to subscriber's identity interception/disclosure and unauthorized user tracking attacks (privacy breach). | C, I | High | Medium | • Threat event initiation (Medium)
    • Adverse impacts (Medium) | Existing controls are in place to prevent (moderately satisfactory). It is a possible attack, however needs physical access and sophistication to execute | Security measures already defined by 3GPP, monitoring/detection mechanisms of a rogue ORU are in place | High | +| T-ORU-01-b | An attacker stands up a rogue O-RU attacking O-DU and beyond (core network) | It provides a means to launch attacks on the availability, integrity, and confidentiality of the Open Front Haul system, ODUs and beyond in the core network. | C, I | High | Low | • Threat event initiation (Medium)
    • Adverse impacts (Low) | Existing controls are in place to prevent, or at least significantly impede, the vulnerability from being exercised. It is a possible attack, however needs physical access and sophistication to execute | 802.1x protocol is supported it can reduce the likelihood of this attack. | Medium | +| T-NEAR-RT-01 | Malicious xApps can exploit UE identification, track UE location and change UE priority | An xApp can receive order via A1 to control a certain UE and if a malfunctioning xApp receives an order to prioritize this UE, then the owner of the malfunctioning xApp knows a VIP that they want to track in a certain area. With this command exposure, the attacker can obtain a rough location of a very important person and change the order from prioritize to deprioritize for a UE;
    Interception of UE identifier | C, I | High | High | • Threat event initiation (High)
    • Adverse impacts (High)
    • Exposure (High) | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC. Further, there is no testing framework in place for xApps yet. | | High | +| T-NEAR-RT-02 | Risk of a malicious xApp on Near-RT RIC to obtain protected information | Deployment of malicious xApps may allow unauthorized access to E2 Nodes, abuse of radio network information, or exploit UE identification and location. | C, I | High | High | • Threat event initiation (High)
    • Exposure (High) | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC. Further, there is no testing framework in place for xApps yet. | | High | + +| | | | | | | | | | | +|---------------|-------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------|---|------|------|-------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------| +| T-NEAR-RT-02A | Risk of a malicious xApp on Near-RT RIC impacting service availability | Deployment of malicious xApps may allow impacting service or exploit slice priority. | A | High | High |
    • Threat event initiation (High)
    • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC. Further, there is no testing framework in place for xApps yet. | | High | +| T-NEAR-RT-03 | Near-RT RIC APIs can be compromised and manipulated due to lack, incorrect or weak authentication mechanism | Near-RT RIC data around services and UEs can be eavesdropped. | C | High | High |
    • Threat event initiation (High)
    • Exposure (High)
    | O-RAN Alliance has not specified yet any Near-RT RIC APIs measures. | | High | +| T-NEAR-RT-03A | Near-RT RIC APIs can be compromised and manipulated due to lack, incorrect or weak authentication mechanism | Unauthenticated APIs can be manipulated causing services disruptions in RAN network | A | High | High |
    • Threat event initiation (High)
    • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any Near-RT RIC APIs measures. | | High | +| T-NEAR-RT-04 | Resources and services provided by Near-RT RIC platform and xApps via APIs can be abused and/or misused | Near-RT RIC data around services and UEs can be eavesdropped by xApps without proper permissions. | C | High | High |
    • Threat event initiation (High)
    • Adverse impacts (High)
    • Exposure (High)
    | O-RAN Alliance has not specified yet any Near-RT RIC APIs measures. | | High | +| T-NEAR-RT-04A | Resources and services provided by Near-RT RIC platform and xApps via APIs can be abused and/or misused | Abuse of resources and misuse of services can produce disruptions and/or outages in the network. | A | High | High |
    • Threat event initiation (High)
    • Adverse impacts (High)
    • Exposure (High)
    | O-RAN Alliance has not specified yet any Near-RT RIC APIs measures. | | High | + +| | | | | | | | | | | +|--------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------|------|--------|-------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------| +| T-NEAR-RT-05 | Risk of deployment of a malicious, non-uniquely identified xApps using a trusted xAppID to access resources and services which they are not entitled to use. | theft of services, data leakage | C, I | High | High |
    • Threat event initiation (High)
    • Exposure (High)
    | O-RAN Alliance has not specified yet any xApp security measures around the xAppID yet. | | High | +| T-NONRT-01 | An attacker gains access to the Non-RT RIC through the SMO to cause a denial of service or degrade the performance of the Non-RT-RIC | Non-RT RIC would not be able to:
    • monitor or trace the network to understand the effect of policy on performance in Near-RT RIC
    • update A1 policy
    • provide exposure and secure delivery of A1 Enrichment Information to Near-RT RIC
    • setup access control rules and the selection of which Enrichment Information ID (Eid) is exposed to a near-RT RIC
    | A | High | Medium |
    • ZTA (Medium)
    • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any security measures around the authentication and access control to the Non RT-RIC. | | High | +| T-NONRT-02 | An attacker gains access to the Non-RT RIC through the SMO for UE tracking | Attacker has access to sensitive data and is able to track a UE | C | High | High |
    • ZTA (High)
    • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any security measures around the authentication and access control to the Non RT-RIC. | | High | +| T-NONRT-03 | An attacker gains access to the Non-RT RIC through the SMO to cause Data Corruption/Modification | A malicious actor who gains unauthorized access to the Non-RT-RIC can modify policy to pass a “False Policy” to the Near-RT-RIC to degrade performance or cause an outage. | C | High | Medium |
    • ZTA (Medium)
    • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any security measures around the authentication and access control to the Non RT-RIC. | | High | +| T-xAPP-01 | An attacker exploits xApps vulnerabilities and misconfiguration to alter data transmitted over A1 or E2 interfaces. | If attackers can find exploitable xApp, they can disrupt the offered network service and potentially take over another xApp or the whole Near-RT RIC.
    The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 or E2 interfaces, extract sensitive information, etc. | I | High | High |
    • Threat event initiation (High)
    • Adverse impacts (High)
    • Exposure (High)
    | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for xApps yet. | | High | +| T-xAPP-01A | An attacker exploits xApps vulnerabilities and misconfiguration to extract sensitive information. | If attackers can find exploitable xApp, they can disrupt the offered network service and potentially take over another xApp or the whole Near-RT RIC.
    The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 or E2 interfaces, extract sensitive information, etc. | C | High | High |
    • Threat event initiation (High)
    • Adverse impacts (High)
    • Exposure (High)
    | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for xApps yet. | | High | + +| | | | | | | | | | | +|------------|---------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|------|--------|-------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------| +| T-xAPP-01B | An attacker exploits xApps vulnerabilities and misconfiguration to disrupt Near-RT RIC functions | If attackers can find exploitable xApp, they can disrupt the offered network service and potentially take over another xApp or the whole Near-RT RIC.
    The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 or E2 interfaces, extract sensitive information, etc. | A | High | High |
    • Threat event initiation (High)
    • Adverse impacts (High)
    • Exposure (High)
    | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for xApps yet. | | High | +| T-xAPP-01C | An attacker exploits xApps vulnerabilities and misconfiguration to gain unauthorized control over Near-RT RIC | If attackers can find exploitable xApp, they can disrupt the offered network service and potentially take over another xApp or the whole Near-RT RIC.
    The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 or E2 interfaces, extract sensitive information, etc. | C, I, A | High | High |
    • Threat event initiation (High)
    • Adverse impacts (High)
    • Exposure (High)
    | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for xApps yet. | | High | +| T-xAPP-02 | Conflicting xApps impact O-RAN system functions to degrade performance or trigger a DoS | An attacker can utilize a malicious xApp that intentionally triggers RRM decisions conflicting with the O-gNB internal decisions to create denial of service or performance degradation. | A | High | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for xApps yet. | | High | +| T-xAPP-03 | An attacker compromises xApp isolation | Gaining unauthorized access to the underlying system provides new opportunities to exploit vulnerabilities in other xApps or O-RAN components to intercept and spoof network traffic, to degrade services (DoS), etc. | C, I, A | High | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for xApps yet. | | High | +| T-xApp-04 | False or malicious A1 policies modify behavior of xApps | A malicious A1 policy can exploit xApp functionality to trigger a DoS, affect performance, or locate a subscriber. | I, A | High | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any xApp security measures around the Onboarding onto SMO and deployment onto Near RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for xApps yet. This attack to be performed requires multiple steps to be achieved by an attacker. | | High | + +| | | | | | | | | | | +|-----------|-----------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|------|--------|----------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------| +| T-rAPP-01 | Conflicting rApps impact O-RAN system functions to degrade performance or trigger a DoS | rApps in the Non-RT RIC performing different functions can be provided by different vendors. This creates the risk that different rApps will take conflicting decisions to set conflicting policies. This can result in performance degradation or outage. | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any rApp security measures around the Onboarding onto SMO and deployment onto Non RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for rApps yet. | | High | +| T-rAPP-02 | An attacker exploits rApp vulnerability for data breach or denial of service | Vulnerabilities can potentially exist in any rApp. If attackers can find exploitable rApp, they can disrupt the offered network service and potentially take over another rApp or the non-RT RIC. The consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 interface, extract sensitive information, etc. | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any rApp security measures around the Onboarding onto SMO and deployment onto Non RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for rApps yet. | | High | +| T-rAPP-03 | An attacker exploits rApps misconfiguration | Security misconfiguration, such as open ports or enabled unused protocols, can potentially exist in an rApp. If attackers can find exploitable rApp, they can disrupt the offered network service and potentially take over another rApp or the whole non-RT RIC. The actual consequences may vary. For example, an attacker may gain the ability to alter data transmitted over A1 interface, extract sensitive information, etc. | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any rApp security measures around the Onboarding onto SMO and deployment onto Non RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for rApps yet. | | High | +| T-rAPP-04 | An attacker bypasses authentication and authorization | An Attacker can exploit an rApp that has weak or misconfigured authentication and authorization to gain access to the rApp and pose as a tenant. | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any rApp security measures around the Onboarding onto SMO and deployment onto Non RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for rApps yet. | | High | + +| | | | | | | | | | | +|-----------|---------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|------|--------|----------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------| +| T-rAPP-05 | An attacker deploys and exploits malicious rApp | An untrusted source may intentionally provide a malicious rApp. A trusted source may have a backdoor intentionally inserted in the rApp. If attackers can find exploitable rApp, they can disrupt the offered network service and potentially take over another rApp or the whole Non-RT RIC. Malicious rApps could impact Non-RT RIC functions such as AI/ML model training, AI policy management, Enrichment information management, Network Configuration Optimization in the purpose of performance degradation, DoS, | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any rApp security measures around the Onboarding onto SMO and deployment onto Non RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for rApps yet. | | High | +| T-rAPP-06 | An attacker bypasses authentication and authorization using an injection attack | It is possible that an attacker to submit requests without prior authentication and authorization by executing an injection attack to manipulate configurations, access logs, perform remote code execution, etc. | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any rApp security measures around the Onboarding onto SMO and deployment onto Non RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for rApps yet. | | High | +| T-rAPP-07 | rApp exploits services | A malicious rApp or a trusted but compromised rApp can exploit services such as O1 services across the R1 interface | A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any rApp security measures around the Onboarding onto SMO and deployment onto Non RT-RIC, authentication and access control, secure configuration, etc. Further, there is no testing framework in place for rApps yet. | | High | + +| | | | | | | | | | | +|--------------|------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------|--------|----------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|--|--------| +| T-PNF-01 | An attacker compromises a PNF to launch attacks against VNFs/CNFs | Data tampering and information disclosure;

    Unauthenticated/unauthorized access of the O-RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data; | C, I | High | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (Medium)
    | This is a likely attack but may need physical access to the PNF. | | High | +| T-PNF-01A | An attacker compromises a PNF to launch Denial of Service attacks against VNFs/CNFs | Denial of service from within for component access and/or function/service offered | A | High | Medium |
    • Threat event initiation (Medium)
    • Adverse impacts (Medium)
    | This is a likely attack but may need physical access to the PNF. | | High | +| T-SMO-01 | An attacker can exploit the misconfigured/poorly implemented authentication mechanism on SMO functions | The data stored in the SMO may be exposed/manipulated to an attacker. | C, I | High | High |
    • ZTA (High)
    • Threat event initiation (High)
    | O-RAN Alliance has not specified yet any SMO security measures around authentication, access control, secure configuration, etc. | | High | +| T-SMO-02 | An attacker can exploit the misconfigured/poorly implemented authorization on SMO functions | An attacker can be able to perform certain actions, e.g. disclose O-RAN sensitive information or alter O-RAN components. | C, I, A | High | High |
    • ZTA (High)
    • Threat event initiation (High)
    | O-RAN Alliance has not specified yet any SMO security measures around authentication, access control, secure configuration, etc. | | High | +| T-SMO-03 | Overload DoS attacks at SMO | Inability to deal with such events affects availability of SMO data and functions. | A | Medium | Medium |
    • ZTA (Medium)
    • Threat event initiation (High)
    | O-RAN Alliance has not specified yet any SMO security measures around authentication, access control, secure configuration, etc. | | Medium | +| T-OPENSRC-01 | Developers use SW components with known vulnerabilities and untrusted libraries that can be exploited by an attacker through a backdoor attack | Attackers can exploit a vulnerability on the open source code and infects a hypervisor, operating system, VM or container with a malware. | C, I, A | High | High | Open-source/COTS support (High) | Vulnerability handling and patch management are not yet defined by O-RAN Alliance. Several CVE have already been discovered on open source software. | | High | + +| | | | | | | | | | | +|--------------|--------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------|--------|---------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------| +| T-OPENSRC-02 | A trusted developer intentionally inserts a backdoor into an open source code O-RAN component. | Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data; | C, I, A | High | Medium | Open-source/COTS support (High) | Vulnerability handling and patch management are not yet defined by O-RAN Alliance. Several CVE have already been discovered on open source software. | | High | +| T-PHYS-01 | An intruder into a site gains physical access to O-RAN components to cause damage or access sensitive data | Data tampering and information disclosure; Denial of service from within for component access and/or function/service offered; Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data; | C, I, A | High | Medium | Exposure (Medium) | O-RAN system has many external interfaces. Different O-Cloud deployment models can be used to implement O-RAN. Several scenarios to implement O-RUs and O-DUs are supported by O-RAN. | | High | +| T-PHYS-02 | An intruder into the exchange over the Fronthaul cable network attempts to gain electronic access to cause damage or access sensitive data | Data tampering and information disclosure; Denial of service from within for component access and/or function/service offered; Unauthenticated/unauthorized access of the O_RAN component leads to compromised performance and/or function/service, lateral attack towards other O-RAN system component(s) from inside, and loss/stolen/tampering of sensitive data; | C, I, A | High | Medium | Exposure (Medium) | O-RAN system has many external interfaces. Different O-Cloud deployment models can be used to implement O-RAN. Several scenarios to implement O-RUs and O-DUs are supported by O-RAN. | | High | +| T-RADIO-01 | Disruption through radio Jamming , Sniffing and Spoofing | Service disruption and information exposure | C, I, A | High | High | Exposure (High) | These attacks are common and not specific to O-RAN. They are likely to occur, hence they need more investigation and consideration. Mitigations to reduce these types of attacks should be defined by O-RAN Alliance. | | High | +| T-RADIO-02 | DoS attacks on cognitive radio networks | Service disruption | A | Medium | High | Exposure (High) | These attacks are common and not specific to O-RAN. They are likely to occur, hence they need more investigation and consideration. Mitigations to reduce these types of attacks should be defined by O-RAN Alliance. | | High | + +| | | | | | | | | | | +|---------|------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|------|--------|----------------------------------------------------------------------------------------------------|----------------------------------------------------------------|--|------| +| T-R1-01 | A malicious actor gains unauthorized access to R1 services | “Service management and exposure services Producer” determines whether the Service Producer is authorized to produce the service. An attacker can perform a spoofing attack to gain unauthorized access to R1 services. | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any R1 security measures. | | High | +| T-R1-02 | Attacker modifies Service Heartbeat message to cause Denial of Service | Attacker can exploit the Service Heartbeat on the R1 by modifying or inserting heartbeat messages to cause denial of service | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any R1 security measures. | | High | +| T-R1-03 | Malicious actor bypasses authentication to Request Data | Attacker can exploit password-based authentication on the R1 to request unauthorized data. Weak password management can easily be exploited. (Certificate-based mutual authentication using TLS and PKI X.509 certificates is recommended). | C, I, A | High | High |
    • • ZTA (High)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any R1 security measures. | | High | +| T-R1-04 | Malicious actor bypasses authorization to Discover Data | “Data registration and discovery service producer” determines whether the Data Producer is authorized to produce the data types. An attacker can perform a spoofing attack to discover available data. | C, I, A | High | High |
    • • ZTA (High)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any R1 security measures. | | High | +| T-R1-05 | A malicious actor gains unauthorized access to data | An attacker can perform a spoofing attack to exploit the Data request and subscription service for the purpose to gain unauthorized access to data. | C, I, A | High | High |
    • • ZTA (High)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any R1 security measures. | | High | +| T-R1-06 | Malicious actor modifies a Data Request | Data Consumers consume the “Data request and subscription service” to request data instances or subscribe to them. An attacker can modify a request to force the consumer to receive a different data set than that intended. Without checks, the received data could be processed, leading to erroneous decisions or triggers. | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any R1 security measures. | | High | +| T-R1-07 | Malicious actor snoops Data Delivery to the Data Consumer | Data delivery messages relate to a particular data request or subscription. The data can be delivered to the Data Consumer in different ways, including: | A | High | High |
    • • ZTA (High)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any R1 security measures. | | High | + +| | | | | | | | | | | +|------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|--------|--------|----------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------|------| +| | |
    • • as part of the payload of a data delivery message,
    • • as a data stream,
    • • from e.g., a REST endpoint, a message bus or object store location.
    An attacker can perform snooping, injection, or modification attacks in the Delivery of Data process. | | | | | | | | +| T-A1-01 | Untrusted peering between Non-RT-RIC and Near-RT-RIC | Malicious Non-RT-RIC peers with a Near-RT-RIC over the A1 interface, or a malicious Near-RT-RIC peers with a Non-RT-RIC over the A1 interface, due to weak mutual authentication. | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any A1 security measures. | | High | +| T-A1-02 | Malicious function or application monitors messaging across A1 interface | Attacker gains access to A1 messaging for reconnaissance | C, I, A | High | High |
    • • ZTA (High)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any A1 security measures. | | High | +| T-A1-03 | Malicious function or application modifies messaging across A1 interface | Internal threat actor can gain access to the messaging across the A1 interface for a MiTM attack to modify or inject policy. This can result in the Near-RT RIC receiving malicious policy. | C, I, A | High | Medium |
    • • ZTA (Medium)
    • • Adverse impacts (High)
    | O-RAN Alliance has not specified yet any A1 security measures. | | High | +| T-A1-04 | Unauthorized access to Non-RT-RIC- or Near-RT-RIC- resources | A malicious actor can gain access to Near-RT-RIC resources or Non-RT-RIC resources over the A1 interface. | C, I, A | High | High |
    • • ZTA (High)
    • • Threat event initiation (High)
    | ZTA: ease of performing reconnaissance attacks without immediate detection

    Threat event initiation: simple to execute for sophisticated inside actors | | High | +| T-GEN-01-a | A successful attack could:
    - Compromise the deployed VNF/CNF | Spoofing, Tampering, Information disclosure, Elevation of Privilege | C, I | Medium | High |
    • • Adverse impacts (Medium),
    • • ZTA (High)
    | Adverse impacts (Medium) - Only one VNF/CNF might be affected, Existing requirements and controls are defined in the O-RAN specifications that may impede successful exercise of the vulnerability.
    ZTA (High): Reconnaissance and availability type attacks | SBOM requirements
    REQ-SEC-SYS-1 | High | +| T-GEN-01-b | A successful attack could:
    - Deployment of malicious VM/Container (Lack of isolation)
    - Exploit host access to escape the host and reach hardware server then the malicious VM/Container can gain root access to the whole server where it resides | Spoofing, Tampering, Information disclosure, Elevation of Privilege | C, I | High | High |
    • • Adverse impacts (High),
    • • ZTA (High)
    | Adverse impacts (High) - Multiple VNFs/CNFs might be affected

    ZTA (High): Reconnaissance and availability type attacks | SBOM requirements
    REQ-SEC-SYS-1 | High | +| T-GEN-02 | A successful attack could:
    - Bypass access controls placed on various | Spoofing, Tampering, Information disclosure, Elevation of Privilege | C, I | Medium | High |
    • • Adverse impacts (Medium),
    • • ZTA (High)
    | Adverse impacts (Medium) - Requirements are in place for user authentication and authorization | REQ-SEC-PASS-1 | High | + +| | | | | | | | | | | +|--------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------|------|--------|------|---------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------|------| +| | resources on O-Cloud
    - Gain increased privilege to specific O-Cloud services
    - Access to restricted areas of the O-Cloud network | | | | | | ZTA (High): Reconnaissance type attacks | REQ-SEC-OCLOUD-1

    REQ-SEC-OCLOUD-2 | | +| T-GEN-03-a | A successful attack could:
    - Make use of a untrusted VM/Container that runs on top of a trusted Hypervisor/Container Engine | Tampering, Information disclosure | C, I | Medium | High | • Adverse impacts (Medium),
    • ZTA (High) | Adverse impacts (Medium) - Only one VNF/CNF might be affected

    ZTA (High): Reconnaissance type attacks | | High | +| T-GEN-03-b | A successful attack could:
    - Make use of a trusted VM/Container that runs on top of an untrusted Hypervisor/Container Engine to intercept communication, replace strong or use weak cryptographic keys, etc. | Tampering, Information disclosure | C, I | High | High | • Adverse impacts (High),
    • ZTA (High) | Adverse impacts (High) - Multiple VNFs/CNFs might be affected

    ZTA (High): Reconnaissance and availability type attacks | | High | +| T-GEN-03-C | A successful attack could:
    - Make use of a trusted VM/Container that runs on top of a trusted Hypervisor/Container Engine that runs on top of an untrusted hardware to intercept communication, replace strong or use weak cryptographic keys, etc. | Tampering, Information disclosure | C, I | High | High | • Adverse impacts (High),
    • ZTA (High) | Adverse impacts (High) - Multiple VNFs/CNFs might be affected

    ZTA (High): Reconnaissance and availability type attacks | | High | +| T-GEN-04 | A successful attack could:
    - Compromise the availability of O-Cloud services
    - Compromise the confidentiality/integrity of O-Cloud services by extracting/modifying critical application data | Information disclosure, Denial of Service | C, A | High | High | • Adverse impacts (High),
    • ZTA (High) | Adverse impacts (High) – No existing controls for interfaces in O-Cloud

    ZTA (High): Reconnaissance and availability type attacks | | High | +| T-GEN-05 (a) | A successful attack could:
    - view insecurely stored credentials and cryptographic materials | Information disclosure, Elevation of Privilege | C | Medium | High | Adverse impacts (Medium),
    ZTA (High) | Adverse impacts (Medium) – Requirements are defined for sensitive data protection in the O-RAN security specifications

    ZTA (High): Reconnaissance type attacks | REQ-SEC-OCLOUD-SS-1
    REQ-SEC-OCLOUD-SS-2
    REQ-SEC-OCLOUD-SS-3 | High | + +| | | | | | | | | | | +|--------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------|---------|--------|--------|---------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------|--------| +| | | | | | | | | SEC-CTL-OCLOUD-SS-1
    SEC-CTL-OCLOUD-SS-2
    SEC-CTL-OCLOUD-SS-3 | | +| T-GEN-05 (b) | A successful attack could:
    - modify insecurely stored credentials and cryptographic materials | Tampering, Elevation of Privilege | I | Medium | Medium | Adverse impacts (Medium),
    ZTA (Medium) | Adverse impacts (Medium) – Requirements are defined for sensitive data protection in the O-RAN security specifications

    ZTA (Medium): Integrity type attacks | REQ-SEC-OCLOUD-SS-1
    REQ-SEC-OCLOUD-SS-2
    REQ-SEC-OCLOUD-SS-3
    SEC-CTL-OCLOUD-SS-1
    SEC-CTL-OCLOUD-SS-2
    SEC-CTL-OCLOUD-SS-3 | Medium | +| T-GEN-06 | A successful attack could:
    - Gain access to the sensitive information
    - Escalate privileges in Applications | Information disclosure, Elevation of Privilege | C | Medium | Medium | Adverse impacts (Medium),
    ZTA (High) | Adverse impacts (Medium) – Requirements are defined for sensitive data protection in the O-RAN security specifications

    ZTA (High): Reconnaissance type attacks | | Medium | +| T-VM-C-01 | A successful attack could:
    - Compromise VM/Container isolation measures
    - Gain higher privileges on host or any of the containers running on that host
    - Perform unauthorized modifications to the contents of host filesystem e.g. install SSH keys, read secrets mounted to the host, and take other malicious actions | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | C, I, A | High | High | • Adverse impacts (High),
    • ZTA (High) | Adverse impacts (High) – No existing requirements

    ZTA (High): Reconnaissance and availability type attacks | | High | +| T-VM-C-02 | A successful attack could:
    - Deploy a new malicious VM/Container configured without network rules, user limitations, etc. to bypass existing defenses within O-Cloud infrastructure
    - Compromise the confidentiality & integrity of co-hosted VMs/Containers and | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | C, I, A | High | Medium | • Adverse impacts (High),
    • ZTA (Medium) | Adverse impacts (High) – No existing requirements

    ZTA (Medium) - Availability type attacks | | High | + +| | | | | | | | | | | +|-------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------|---------|------|--------|---------------------------------------------|----------------------------------------------------------------------------------------------|--|------| +| | tenants
    - Launch DDOS attacks on co-hosted VMs/Containers and host services thereby degrading their performance | | | | | | | | | +| T-VM-C-03 | A successful attack could:
    - Retrieve/manipulate VNF/CNF sensitive data (e.g. passwords, private keys, subscription data, logs) | Tampering, Information disclosure | C, I | High | High | • Adverse impacts (High),
    • ZTA (High) | Adverse impacts (High) – No existing requirements
    ZTA (High): Reconnaissance type attacks | | High | +| T-VM-C-04-a | A successful attack could:
    - Cause migration Flooding: VM/Container performance degradation and VM/Container crashes | Tampering, Information disclosure, Denial of Service | C, I, A | High | Medium | • Adverse impacts (High),
    • ZTA (Medium) | Adverse impacts (High) – No existing requirements
    ZTA (Medium): Availability type attacks | | High | +| T-VM-C-04-b | "A successful attack could:
    - Sniff the packets that are exchanged between the source and destination servers
    - Read the migrated memory pages
    - Monitor and/or modify the received packets while continuing to forward them to victim VM/Container" | Tampering, Information disclosure, Denial of Service | C, I, A | High | High | • Adverse impacts (High),
    • ZTA (High) | Adverse impacts (High) – No existing requirements
    ZTA (High): Reconnaissance type attacks | | High | +| T-VM-C-05 | A successful attack could:
    - Misguide the Virtualization layer to reduce the resource of or delete a VM/Container on which a VNF/CNF is running. This can result in the reliability, availability or even illegal termination of a VNF/CNF and hence the denial of service
    - Misguide the O-Cloud platform to detach a hardware accelerator from a VNF/CNF | Denial of Service | A | High | Medium | • Adverse impacts (High),
    • ZTA (Medium) | Adverse impacts (High) – No existing requirements
    ZTA (Medium): Availability type attacks | | High | + +| | | | | | | | | | | +|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------|---------|--------|------|---------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------|------| +| T-VM-C-06 | A successful attack could:
    - Access to data not erased from a terminated VNF/CNF or any VNF/CNF that has released resources | Information disclosure | C | High | High | • Adverse impacts (High),
    • ZTA (High) | Adverse impacts (High) – No existing requirements

    ZTA (High): Reconnaissance and availability type attacks | | High | +| T-IMG-01 | A successful attack could:
    - Insert malicious code that will subsequently get run in the production environment | Tampering, Information disclosure | C, I | Medium | High | • Adverse impacts (Medium),
    • ZTA (High) | Adverse impacts (Medium) – Requirements are defined for image protection in the O-RAN security specifications

    ZTA (High): Reconnaissance and availability type attacks | REQ-SEC-ALM-PKG-1 to REQ-SEC-ALM-PKG-15

    SEC-CTL-ALM-PKG-1 to SEC-CTL-ALM-PKG-4 | High | +| T-IMG-02 | A successful attack could:
    - Intercept network traffic intended for registries and steal developer or administrator credentials within that traffic. Thus, could be used to provide fraudulent or outdated images to orchestrators, etc. | Tampering, Information disclosure | C, I | Medium | High | • Adverse impacts (Medium),
    • ZTA (High) | Adverse impacts (Medium) – Requirements are defined for image protection in the O-RAN security specifications

    ZTA (High): Reconnaissance and availability type attacks | REQ-SEC-ALM-PKG-1 to REQ-SEC-ALM-PKG-15

    SEC-CTL-ALM-PKG-1 to SEC-CTL-ALM-PKG-4 | High | +| T-IMG-03 | A successful attack could:
    - Secrets embedded within a VM/Container image can be stolen
    - Secrets embedded within a VM/Container image can be modified | Spoofing, Tampering, Information disclosure | C, I | Medium | High | • Adverse impacts (Medium),
    • ZTA (High) | Adverse impacts (Medium) – Requirements are defined for image protection in the O-RAN security specifications

    ZTA (High): Reconnaissance and availability type attacks | REQ-SEC-ALM-PKG-1 to REQ-SEC-ALM-PKG-15

    SEC-CTL-ALM-PKG-1 to SEC-CTL-ALM-PKG-4 | High | +| T-IMG-04 | A successful attack could:
    - Build a custom image on the host that includes malware and then may deploy container using that custom image | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | C, I, A | Medium | High | • Adverse impacts (Medium),
    • ZTA (High) | Adverse impacts (Medium) – Requirements are defined for image protection in the O-RAN security specifications

    ZTA (High): Reconnaissance and availability type attacks | REQ-SEC-ALM-PKG-1 to REQ-SEC-ALM-PKG-15

    SEC-CTL-ALM-PKG-1 to SEC-CTL-ALM-PKG-4 | High | +| T-VL-01 | A successful attack could:
    - Gain control over the host of a server or install a malicious Hypervisor/Container Engine/Host OS and | Spoofing, Tampering, Information disclosure, Denial of Service and Elevation of privilege | C, I, A | High | High | • Adverse impacts (High),
    • ZTA (High) | Adverse impacts (High) - No existing requirements

    ZTA(High) - Reconnaissance and availability type of attacks | | High | + +| | | | | | | | | | | +|---------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------|---|--------|--------|-------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------| +| | exploit that to run malicious applications on the VM/Container that run on top of the host. This would enable the attacker to control all the VMs/Containers running on the host. | | | | | | | | | +| T-VL-02 | A successful attack could cause:
    - Failure of the physical machine to start at all
    - Physical machine entering a safe-mode
    - Physical machine continuing boot regardless of the integrity measurements | Tampering | I | High | Medium |
    • Adverse impacts (High),
    • ZTA (Medium)
    | Adverse Impact (High) - No existing requirements

    ZTA(Medium) - Availability type attacks | | High | +| T-VL-03 | A successful attack could:
    - cause denial-of-service against the service discovery infrastructure to prevent O-Cloud to react to changing resource requirements properly | Denial of Service | A | Medium | Medium | Adverse impacts (Medium),
    ZTA (Medium) | Adverse impacts (Medium) – Requirements are defined for O-Cloud authentication and authorization in the O-RAN security specifications.

    ZTA (Medium): Availability type attacks | REQ-SEC-OCLOUD-O2dms-1
    REQ-SEC-OCLOUD-O2dms-2
    REQ-SEC-OCLOUD-O2dms-3
    REQ-SEC-OCLOUD-O2dms-4
    REQ-SEC-OCLOUD-O2ims-1
    REQ-SEC-OCLOUD-O2ims-2
    REQ-SEC-OCLOUD-O2ims-3
    REQ-SEC-OCLOUD-O2ims-4
    REQ-SEC-OCLOUD-NotifAPI-1
    REQ-SEC-OCLOUD-NotifAPI-2
    SEC-CTL-OCLOUD-INTERFACE-1
    SEC-CTL-OCLOUD-INTERFACE-2
    SEC-CTL-OCLOUD-INTERFACE-3 | Medium | + +| | | | | | | | | | | +|------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------|---------|------|------|---------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------|--------| +| | | | | | | | | REQ-SEC-OCLOUD-ISO-1
    REQ-SEC-OCLOUD-ISO-2
    REQ-SEC-OCLOUD-ISO-3
    REQ-SEC-OCLOUD-ISO-4 | | +| T-O2-01 | A successful attack could:
    - Tamper/alter/disclose requests and services sent over O2 between O-Cloud and SMO, hence the virtualized resource or relevant status information is not as requested
    - Affect the normal operation of the O-Cloud, and even causes DoS attacks, information leakage. | Tampering, Information disclosure, Denial of Service | C, I, A | Low | High |
    • • Adverse impacts (Low),
    • • ZTA (High)
    |

    Adverse impacts (Low) – Requirements are defined for the protection of O2 interface in the O-RAN security specifications

    ZTA (High): Reconnaissance and availability type attacks

    | REQ-SEC-O2-1

    SEC-CTL-O2-2

    REQ-SEC-DOS-1 | Medium | +| T-OCAPI-01 | A successful attack could:
    - Cryptographic keys or other security critical data of an instantiated VNF/CNF could be stolen by an attacker with access to the virtualization layer
    - The virtualized resource provided by the Virtualization layer to the instantiated VNF/CNF can be manipulated | Tampering, Information disclosure, Denial of Service | C, I, A | Low | High |
    • • Adverse impacts (Low),
    • • ZTA (High)
    |

    Adverse impacts (Low) – Requirements are defined for the protection of O-Cloud API in the O-RAN security specifications

    ZTA (High): Reconnaissance and availability type attacks

    | REQ-SEC-O2-1

    SEC-CTL-O2-2

    REQ-SEC-DOS-1 | Medium | +| T-HW-01 | A successful attack could:
    - Maliciously placed VM/Container extracts information from the target VM/Container with the side channel attack | Tampering, Information disclosure, Denial of Service | C, I, A | High | High |
    • • Adverse impacts (High),
    • • ZTA (High)
    |

    Adverse Impact (High) - No existing requirements

    ZTA (High): Reconnaissance and availability type attacks

    | | High | +| T-HW-02 | A successful attack could:
    - Extract useful information such as cryptographic keys from the target VM/Container to use them for traffic eavesdropping and man-in-the-middle attacks. | Tampering, Information disclosure, Denial of Service | C, I, A | High | High |
    • • Adverse impacts (High),
    • • ZTA (High)
    |

    Adverse Impact (High) - No existing requirements

    ZTA (High): Reconnaissance and availability type attacks

    | | High | + +| | | | | | | | | | | +|--------------|----------------------------------------------------------------------------------------------------------------------------------------------|------------------------|---|------|--------|--------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------|--|------| +| T-AAL-01 | A successful attack could:
    - tamper the requests/responses sent between the AAL components, the O-Cloud platform and O-RAN APPs/VNFs/CNFs | Tampering | I | High | Medium | Adverse impacts (Medium), ZTA (High) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications

    ZTA (Medium): Integrity type attacks | | High | +| T-AAL-02 | A successful attack could:
    - cause DoS attack or increased traffic on AAL interfaces | Denial of Service | A | High | Medium | Adverse impacts (Medium), ZTA (High) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications

    ZTA (Medium): Availability type attacks | | High | +| T-AAL-03 (a) | Fail to clear resources | Information disclosure | C | High | High | Adverse impacts (High), ZTA (High) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications

    ZTA (High): reconnaissance type attacks | | High | +| T-AAL-03 (b) | Fail to clear resources | Denial of service | A | High | Medium | Adverse impacts (High), ZTA (Medium) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications

    ZTA (Medium): Availability type attacks | | High | +| T-AAL-04 (a) | HAM compromise | Tampering | I | High | Medium | Adverse impacts (High), ZTA (Medium) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications

    ZTA (Medium): Integrity type attacks | | High | +| T-AAL-04 (b) | HAM compromise | Denial of service | A | High | Medium | Adverse impacts (High), ZTA (Medium) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications

    ZTA (Medium): Availability type attacks | | High | +| T-AAL-05 (a) | Malicious memory accesses | Information disclosure | C | High | High | Adverse impacts (High), ZTA (High) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications

    ZTA (High): reconnaissance type attacks | | High | +| T-AAL-05 (b) | Malicious memory accesses | Tampering | I | High | Medium | Adverse impacts (High), ZTA (Medium) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications

    ZTA (Medium): Integrity type attacks | | High | +| T-AAL-05 (c) | Malicious memory accesses | Denial of service | A | High | Medium | Adverse impacts (High), ZTA (Medium) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications

    ZTA (Medium): Availability type attacks | | High | +| T-AAL-06 (a) | Software attacks | Information disclosure | C | High | High | Adverse impacts (High), ZTA (High) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications | | High | + +| | | | | | | | | | | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------|---------|--------|--------|-----------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------|--------| +| | | | | | | | ZTA (High): reconnaissance type attacks | | | +| T-AAL-06 (b) | Software attacks | Tampering | I | High | Medium | Adverse impacts (High), ZTA (Medium) | Adverse impacts (High) – Not security requirements yet for AAL in O-RAN security specifications

    ZTA (Medium): Integrity type attacks | | High | +| T-O-CLOUD-ID-01 | In the O-Cloud environment, the reuse of IDs from deleted objects for new objects can lead to unintended data associations, leaks, and operational disruptions. | Tampering, Information disclosure | C, I | High | High | Adverse impacts (High), ZTA (High) | Adverse impacts (High) – Not security requirements yet for O-Cloud ID in O-RAN security specifications

    ZTA (High): reconnaissance and integrity type attacks | | High | +| T-O-CLOUD-ID-02 | In O-Cloud deployments, replacing failed machines without proper management of their corresponding Node objects can lead to resource mismatches, stale data inheritance, and network inconsistencies. | Spoofing, Tampering, Information disclosure, Denial of Service | C, I, A | High | High | Adverse impacts (High), ZTA (High) | Adverse impacts (High) – Not security requirements yet for O-Cloud ID in O-RAN security specifications

    ZTA (High): reconnaissance, integrity, and availability type attacks | | High | +| T-O-CLOUD-ID-03 | In the O-Cloud environment, improper management of object IDs can lead to overlaps, inconsistencies, unauthorized access, and operational disruptions. | Spoofing, Tampering, Information Disclosure, Repudiation, Elevation of Privilege, Denial of Service | C, I, A | High | High | Adverse impacts (High), ZTA (High) | Adverse impacts (High) – Not security requirements yet for O-Cloud ID in O-RAN security specifications

    ZTA (High): reconnaissance, integrity, and availability type attacks | | High | +| T-ADMIN-01 | A successful attack could:
    - Lead to the inability to react to changing resource requirements
    - Operators may be unable to retrieve logs, telemetry data
    - Prevents the O-Cloud software update (VNFs/CNFs, VL) to exploit a known security flaw in the O-Cloud software | Denial of Service | A | Medium | Medium | • Adverse impacts (Medium),
    • ZTA (Medium) | Adverse impacts (Medium) – Requirements are defined for the protection against DoS attacks and for the protection of O-Cloud API and O2 interface in the O-RAN security specifications

    ZTA (Medium): Availability type attacks | REQ-SEC-DOS-1 | Medium | +| T-ADMIN-02 | A successful attack could:
    - Deploy new instances and disrupt existing O-Cloud services
    - Submit compromised VM/Container images that unsuspecting tenants then use to initiate O-Cloud services
    - Extract business data, | Tampering, Information disclosure, Denial of Service and Elevation of privilege | C, I, A | Medium | High | • Adverse impacts (High),
    • ZTA (High) | Adverse impacts (Medium) – Requirements are defined for the protection of O-Cloud API and O2 interface in the O-RAN security specifications

    ZTA (High): Reconnaissance and availability type attacks | REQ-SEC-PASS-1
    REQ-SEC-O2-1
    SEC-CTL-O2-2
    REQ-SEC-DOS-1 | High | + +| | | | | | | | | | | +|---------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------|---|------|--------|---------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--------| +| | configuration data, user data and possibly credentials
    - Create backups of VM/Container instances or export VM/Container images | | | | | | | | | +| T-AIML-IM-1 | A successful attack could:
    - Take alter a subset of the training data by inserting or modifying training samples | Integrity | I | High | Low |
    • Impact on integrity (High)
    • Threat event initiation (low)
    |
    • Impact on integrity: Bad training data will cause the model to behave incorrectly
    • Threat event initiation: needs high sophistication to execute
    | | Medium | +| T-AIML-IM-2 | A successful attack could:
    - generate adversarial examples in the model | Tampering | I | High | Low |
    • Impact on integrity (High)
    • Threat event initiation (low)
    |
    • Impact on integrity: major change in normal AI/ML functioning
    • Threat event initiation: needs high sophistication to execute
    | | Medium | +| T-AIML-IM-3 | A successful attack could:
    - mis-assign labels to training data | Tampering | I | High | Low |
    • Impact on integrity (High)
    • Threat event initiation (low)
    |
    • Impact on integrity: major change in normal AI/ML functioning
    • Threat event initiation: needs high sophistication to execute
    | | Medium | +| T-AIML-IM-4 | A successful attack could:
    - allow an adversary to submit queries to the model and receive predictions (either labels or model confidences) and confidential data | Confidentiality | C | High | Low |
    • Impact on confidentiality (High)
    • Threat event initiation (low)
    |
    • Impact on confidentiality: major change in normal AI/ML functioning
    • Threat event initiation: needs high sophistication to execute
    | | Medium | +| T-AIML-DP-01 | A successful attack could:
    -inject poisoned data which can be consumed by AI/ML for training. | Tampering | I | High | Medium |
    • Impact on integrity (High)
    • Threat event initiation (Medium)
    |
    • Impact on integrity: major change in normal AI/ML functioning
    • Threat event initiation: needs sophistication to execute
    | | High | +| T-AIML-DP-02 | A successful attack could:
    -enable the attacker to get more details about the AI/ML algorithms being used and parameters configured if any | Tampering | I | High | Medium |
    • Impact on integrity (High)
    • Threat event initiation (Medium)
    |
    • Impact on integrity: major change in normal AI/ML functioning
    • Threat event initiation: needs sophistication to execute
    | | High | +| T-AIML-DP-03 | A successful attack could:
    - enable the attacker to modify the behaviour of AI/ML algorithm with slow poisoning | Tampering | I | High | Medium |
    • Impact on integrity (High)
    • Threat event initiation (Medium)
    |
    • Impact on integrity: major change in normal AI/ML functioning
    • Threat event initiation: needs sophistication to execute
    | | High | +| T-AIML-MEI-01 | A successful attack based on level of information available to attacker can | Information Disclosure | C | High | Medium |
    • Impact on confidentiality (High)
    |
    • Impact on confidentiality: Knowledge of information used in training gets exposed
    | | High | + +| | | | | | | | | | | +|---------------|---------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------|----|------|--------|--------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------|--|--------| +| | result in disclosing specific individual's data used in training the model | | | | | • Threat event initiation (Medium) | • Threat event initiation needs sophistication to execute | | | +| T-AIML-MEI-02 | A successful attack based on analysis methods used by the attacker can result in disclosing specific individual's data used in training the model | Information Disclosure | C | High | Medium | • Impact on confidentiality (High)
    • Threat event initiation (Medium) | • Impact on confidentiality: Knowledge of information used in training gets exposed
    • Threat event initiation needs sophistication to execute | | High | +| T-AIML-MEI-03 | A successful target based attack can result in disclosing specific individual's data or a group's data used in training the model | Information Disclosure | C | High | Medium | • Impact on confidentiality (High)
    • Threat event initiation (Medium) | • Impact on confidentiality: Knowledge of information used in training gets exposed
    • Threat event initiation needs sophistication to execute | | High | +| T-AIML-ME-01 | A successful attack could:
    -Cause theft of intellectual property
    -Undermine the original developer's competitive advantage | Confidentiality | C | High | Low | • Impact on confidentiality (High)
    • Threat event initiation (low) | • Impact on confidentiality: Disclosure of high value information
    • Threat event initiation: needs high sophistication to execute | | Medium | +| T-AIML-ME-02 | A successful attack could:
    -Cause privacy breaches | Confidentiality | C | High | Low | • Impact on confidentiality (High)
    • Threat event initiation (low) | • Impact on confidentiality: Disclosure of high value information
    • Threat event initiation: needs high sophistication to execute | | Medium | +| T-AIML-ME-03 | A successful attack could:
    -allow adversarial attacks
    -allow targeted attacks | Tampering | I | High | Low | • Impact on integrity (High)
    • Threat event initiation (low) | • Impact on integrity: major change in normal AI/ML functioning
    • Threat event initiation: needs high sophistication to execute | | Medium | +| T-AIML-MOI-01 | A successful attack could:
    - Cause disclosure of sensitive/proprietary data | Confidentiality | C | High | Medium | • Impact on confidentiality (High)
    • Threat event initiation (medium) | • Impact on confidentiality: Disclosure of high value information
    • Threat event initiation: needs medium sophistication to execute | | High | +| T-AIML-MOI-02 | A successful attack could:
    - allow an attacker to reconstruct the original training data with higher accuracy | Confidentiality | C | High | Low | • Impact on confidentiality (High)
    • Threat event initiation (low) | • Impact on confidentiality: major change in normal AI/ML functioning
    • Threat event initiation: needs high sophistication to execute | | Medium | +| T-AIML-SC-01 | A successful attack could:
    -corrupt or manipulate training datasets
    - cause degraded performance, wrong decisions, or even | Tampering, Denial of Service | IA | High | Medium | • Impact on confidentiality (High)
    • Threat event initiation (Medium) | needs sophistication to execute | | High | + +| | | | | | | | | | | +|--------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|----|------|--------|-------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--------| +| | backdoors in the final system | | | | | | | | | +| T-AIML-SC-02 | A successful attack could:
    -inject malicious code or logic into the AI model itself during training or deployment | Tampering, Confidentiality | CI | High | Low |
    • • Impact on confidentiality (High)
    • • Threat event initiation (low)
    | needs high sophistication to execute | | Medium | +| T-AIML-SC-03 | A successful attack could:
    -infect the model with malicious code that remains dormant until it receives a specific trigger | Tampering, Confidentiality | CI | High | Low |
    • • Impact on confidentiality (High)
    • • Threat event initiation (low)
    | needs high sophistication to execute | | Medium | +| T-AIML-SC-04 | A successful attack could:
    -manipulate the hardware used for AI processing, such as GPUs, ASICs, or FPGAs | Tampering, Confidentiality | CI | High | Low |
    • • Impact on confidentiality (High)
    • • Threat event initiation (low)
    | needs high sophistication to execute | | Medium | +| T-AIML-SC-05 | A successful attack could:
    -inject malicious code or exfiltrate sensitive information from the target system. | Tampering, Confidentiality | CI | High | Low |
    • • Impact on confidentiality (High)
    • • Threat event initiation (low)
    | needs high sophistication to execute | | Medium | +| T-AIML-SC-06 | A successful attack could:
    -insert vulnerabilities or backdoors that attackers can exploit | Tampering, Confidentiality | CI | High | Low |
    • • Impact on confidentiality (High)
    • • Threat event initiation (low)
    | needs high sophistication to execute | | Medium | +| T-AIML-OI-01 | A successful attack could cause :
    - service disruption of the O-RAN elements that are using configuration / policies derived from the manipulated output of a model . | Denial of Service | A | High | Medium |
    • • Impact on Availability (High)
    • • Adverse impacts (Medium)
    |
    • • Impact on Availability (High): Prolonged interruption of operations.
    • • Adverse impacts (Medium) – O-RAN Alliance has specified security for O-RAN interfaces at the transport layers thereby mitigating access to O-RAN functions through the interfaces. The O-RAN Alliance has not yet specified security for regarding the Training or test data sets collected externally or internally, Trained ML model , ML prediction results .
    | | High | +| T-AIML-OI-02 | AI/ML models are used to perform QoE optimization and QoE based traffic steering in O-RAN [i.14]. A | Tampering | I | High | Medium |
    • • Impact on Integrity (High)
    • • Adverse impacts (Medium)
    |
    • • Impact on Integrity (High): Major change in normal AI/ML system functioning.
    • • Adverse impacts (Medium) – O-RAN Alliance has specified
    | | High | + +| | | | | | | | | | | +|--------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------|---|------|--------|----------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--------| +| | carefully crafted manipulation of the output of AI/ML model can be used to degrade the QoE of a subscriber or a group of subscribers. | | | | | | security for O-RAN interfaces at the transport layers thereby mitigating access to O-RAN functions through the interfaces. The O-RAN Alliance has not yet specified security for regarding the Training or test data sets collected externally or internally, Trained ML model , ML prediction results . | | | +| T-AIML-MP-01 | A successful attack can change the parameters file which will cause the model to make incorrect predictions. | Tampering | I | High | Medium |
    • • Impact on integrity (High)
    • • Threat event initiation (Medium)
    |
    • • Impact on integrity: major change in normal AI/ML functioning
    • • Threat event initiation needs sophistication to execute
    | | High | +| T-AIML-MP-02 | A successful attack can change the inference algorithm which will cause the model to make incorrect predictions. | Tampering | I | High | Medium |
    • • Impact on integrity (High)
    • • Threat event initiation (Medium)
    |
    • • Impact on integrity: major change in normal AI/ML functioning
    • • Threat event initiation needs sophistication to execute
    | | High | +| T-AIML-MP-03 | A successful attack can change the learning algorithm which will cause the model to make incorrect predictions. | Tampering | I | High | Medium |
    • • Impact on integrity (High)
    • • Threat event initiation (Medium)
    |
    • • Impact on integrity: major change in normal AI/ML functioning
    • • Threat event initiation needs sophistication to execute
    | | High | +| T-AIML-MP-04 | A successful attack could:
    • - create a Trojan trigger in the model
    • -send malicious local model updates in federated learning
    | Integrity | I | High | Low |
    • • Impact on integrity (High)
    • • Threat event initiation (low)
    |
    • • Impact on integrity: Disclosure of high value information
    • • Threat event initiation: needs high sophistication to execute
    | | Medium | +| T-AIML-MS-01 | A successful attack could:
    • modify data which can result in a skewed trained model resulting in incorrect ML output
    | Tampering | I | High | Medium |
    • • Impact on integrity (High)
    • • Threat event initiation (Medium)
    |
    • • Impact on integrity: major change in normal AI/ML functioning
    • • Threat event initiation needs sophistication to execute
    | | High | +| T-AIML-MS-02 | A successful attack could:
    • manipulate the feedback mechanism used by AI/ML for continuous improvement during deployment, which can be result in a skewed trained model resulting in incorrect ML output
    | Tampering | I | High | Medium |
    • • Impact on integrity (High)
    • • Threat event initiation (Medium)
    |
    • • Impact on integrity: major change in normal AI/ML functioning
    • • Threat event initiation needs sophistication to execute
    | | High | + +| | | | | | | | | | | +|--------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|----|------|--------|-----------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------|--|--------| +| T-AIML-TL-01 | A successful attack could:
    - corrupt or manipulate training datasets
    - cause degraded performance, wrong decisions, or even backdoors in the final system | Tampering | I | High | Medium |
    • Impact on integrity (High)
    • Threat event initiation (Medium)
    | needs sophistication to execute | | High | +| T-AIML-TL-02 | A successful attack could:
    - extract sensitive information about its architecture and parameters | Confidentiality | C | High | Low |
    • Impact on confidentiality (High)
    • Threat event initiation (low)
    | needs high sophistication to execute | | Medium | +| T-AIML-TL-03 | A successful attack could:
    - bypass security systems or cause misclassifications in critical applications like self-driving cars or healthcare. | Tampering | I | High | Low |
    • Impact on integrity (High)
    • Threat event initiation (low)
    | needs high sophistication to execute | | Medium | +| T-AIML-TL-04 | A successful attack could:
    - infect the model with malicious code that remains dormant until it receives a specific trigger | Tampering, Confidentiality | CI | High | Low |
    • Impact on confidentiality and integrity (High)
    • Threat event initiation (low)
    | needs high sophistication to execute | | Medium | +| T-AIML-EL-01 | A successful attack could:
    - deduce the structure of the neural network, including the types of layers, their sequence, and possibly hyperparameters | Confidentiality | C | High | Low |
    • Impact on confidentiality (High)
    • Threat event initiation (Low)
    | needs high sophistication to execute | | Medium | +| T-AIML-EL-02 | A successful attack could:
    - make inferences about the input data, potentially leading to privacy breaches, especially if the data is sensitive | Confidentiality | C | High | Low |
    • Impact on confidentiality (High)
    • Threat event initiation (low)
    | needs high sophistication to execute | | Medium | +| T-AIML-EL-03 | A successful attack could:
    - maximize energy consumption or computation time, leading to a denial of service by overloading | Denial of Service | A | High | Low |
    • Impact on availability (High)
    • Threat event initiation (low)
    | needs high sophistication to execute | | Medium | + +| | | | | | | | | | | +|--------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------|------|--------|----------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------| +| | the system or draining battery life. | | | | | | | | | +| T-AIML-EV-01 | A successful attack could:
    - Compromise Authentication Systems tricking AI/ML systems into granting access to unauthorized users
    - Undermine Integrity of Data by tricking AI/ML systems into drawing incorrect conclusions | Tampering | I | High | Medium |
    • • Impact on integrity (High)
    • • Threat event initiation (Medium)
    | needs sophistication to execute | | High | +| T-TS-01 | Disruption or manipulation of the time synchronization process within the O-Cloud environment can lead to severe security and operational issues. | An attacker may target the time synchronization mechanisms to alter time settings across nodes, leading to data integrity loss, authentication and authorization bypass, and operational disruption. | I, A | High | Medium | Impact of Integrity and Availability (High)

    Threat Event Initiation (Medium) | Impact of Integrity and Availability (High): due to potential widespread operational and security impacts, including data integrity loss and operational disruptions affecting multiple nodes.

    Threat Event Initiation (Medium): it requires elevated privileges to modify time synchronization settings. | | High | + +# Annex: Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.12.06 | 05.00 | Final version 05.00 | +| 2024.12.04 | 04.00.04 | Update according to received notes from November train review | +| 2024.12.03 | 04.00.03 | Update according to received notes from November train review | +| 2024.12.02 | 04.00.02 | Update according to received notes from November train review | +| 2024.11.25 | 04.00.01 | Integration of CRs:
    • NOK CRs: CR0181, CR0187, CR0190, CR0201, CR0203, CR0206, CR0207, CR0208, CR0210
    • NEC CRs: CR0027, CR0029
    • WG11 CRs: CR0048, CR0050
    • ERI CR: CR0153
    | +| 2024.07.26 | 04.00 | Final version 04.00 | +| 2024.07.24 | 03.00.03 | Update according to received notes from July train review | +| 2024.07.23 | 03.00.02 | Update according to received notes from July train review | +| 2024.07.10 | 03.00.01 | Implemented CRs: NOK CR0155, NOK CR0142, NOK CR0160, NOK CR0161, NOK CR0162, NOK CR0167, NOK CR0170, NOK CR0171, NOK CR0172, NEC CR0018, NEC CR0023, WG11 CR 0035, WG11 CR 0044, ATT CR 0022, ATT CR 0044, RMI CR 0020, RMI CR 0027, MTR CR 0096 | +| 2024.03.27 | 03.00 | Final version 03.00 | +| 2024.03.19 | 02.00.02 | Addressed editorial notes | +| 2024.03.15 | 02.00.01 | Implemented CRs ERI CR0103, MTR CR0081, SYM CR0040, NEC CR0007, NEC CR0011, WG11 CR0029 | +| 2023.11.22 | 02.00 | Final version 02.00 | +| 2023.11.21 | 01.00.02 | Update according to received notes from November train review | +| 2023.11.03 | 01.00.01 | Implemented CRs WG11 CR0015, MTR CR0004 | +| 2019.01.31 | 01.00 | Final version 01.00 | +| 2019.01.24 | 00.00.02 | Implemented CRs ERI-0011, NOK-0032 and DCM-0008 | +| 2019.01.22 | 00.00.01 | Create initial O-RAN version, with change-marks from previous content. | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/03e21275497df8922a164ac052228b6d_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/03e21275497df8922a164ac052228b6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8bb9c3905bbcc776062dd0b6856af43614ab351e --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/03e21275497df8922a164ac052228b6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bf438b48a4ba98f6295f6d2bfd5f405b89c0ba8b19b725241f8c5fb6e1204783 +size 48930 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/29e779cca60cb3268691f257b39a1c79_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/29e779cca60cb3268691f257b39a1c79_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..926ed60f58365587606184e68945f047a85721f7 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/29e779cca60cb3268691f257b39a1c79_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a7b2dbd1c7764ee6467ebd622f70834e86631f3a199afc79e4962cc7ff078060 +size 23348 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/676c91b64382565d972aaef1aeb60f35_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/676c91b64382565d972aaef1aeb60f35_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..17e9aeebaaf53d6100482d20b8dbdbd363ecb52b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/676c91b64382565d972aaef1aeb60f35_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b0f20f21b66dfe1b951c86e5ef199d9677e37716f224c6a93c40e9a0a2979aa5 +size 4549 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/6e52e241790620ef6fb7dcc1fcba752b_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/6e52e241790620ef6fb7dcc1fcba752b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c41fd8d3fb545804166d8d35a0f935d819b0bc44 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/6e52e241790620ef6fb7dcc1fcba752b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:02a347be6fe8cffd6a392963c620d5cf20ccac3bede339153c584d1e67bcfc3f +size 32471 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..08a9c509da7e591b85ce9c11c7659f729776badc --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e51e29a8c647908fe9f48f56b660f7378772dafa9202a271bcb2032f560fafe1 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/a4a9ce2dd165f342247cbb46ac873e29_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/a4a9ce2dd165f342247cbb46ac873e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..56b5822edcef7edd7077d1556912a099052acd59 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/a4a9ce2dd165f342247cbb46ac873e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:38408dea1b21cb6fdd73bd998858e4f2d65c89dc137dde012c1be9f77af1a9ad +size 60786 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/bb19a24fab1cb3a2b51f82fef2ea3b61_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/bb19a24fab1cb3a2b51f82fef2ea3b61_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1e4339cbe312363fdb23b8f050547dd70447af48 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/bb19a24fab1cb3a2b51f82fef2ea3b61_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d976b7dcf50b3ae7bff9c51ec8e99373a2c9422e88bfa5330e2e6919a312e40d +size 4528 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/c8c280fb70ee49fec80a2a92fb3cc3fa_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/c8c280fb70ee49fec80a2a92fb3cc3fa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..211b3e3c41561cecff2ae09d96a95a84628eec4d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/c8c280fb70ee49fec80a2a92fb3cc3fa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4bc86e5c6afb3e8822db8737a4f9651627f6881da187c576f75bbb1c6fd828a8 +size 4492 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/d995e216ca151dc1a054401a6e3b8c0b_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/d995e216ca151dc1a054401a6e3b8c0b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..998bae6f9731f6d187289686a19789337c554547 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/d995e216ca151dc1a054401a6e3b8c0b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:170954d25c104cebaf295cc13d2789f3640311a26c20a890e1b284835ff09bcf +size 6412 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/raw.md b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..cf3492f17465221ec1084931cc533d13da908bd3 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00/raw.md @@ -0,0 +1,1135 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****Security Protocols Specifications** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|------------------------------------------------------------------------------|----| +| Contents..... | 2 | +| Foreword ..... | 5 | +| Modal verbs terminology ..... | 5 | +| 1 Scope..... | 6 | +| 2 References..... | 6 | +| 2.1 Normative references ..... | 6 | +| 2.2 Informative references..... | 9 | +| 3 Definition of terms, symbols and abbreviations ..... | 9 | +| 3.1 Terms..... | 9 | +| 3.2 Symbols..... | 9 | +| 3.3 Abbreviations ..... | 9 | +| 4 Security protocols specifications for O-RAN compliant implementation ..... | 10 | +| 4.1 SSH..... | 10 | +| 4.1.1 General requirements..... | 10 | +| 4.1.2 Required ciphers..... | 10 | +| 4.2 TLS..... | 12 | +| 4.2.1 General Requirements ..... | 12 | +| 4.2.2 TLS Protocol Profile..... | 12 | +| 4.2.3 TLS Certificate Profile ..... | 12 | +| 4.3 Support NETCONF over secure Transport..... | 15 | +| 4.4 DTLS..... | 15 | +| 4.4.1 General requirements..... | 15 | +| 4.4.2 DTLS Protocol Profile..... | 16 | +| 4.4.3 Certificate Profile ..... | 16 | +| 4.5 IPsec..... | 16 | +| 4.5.1 Overview ..... | 16 | +| 4.5.2 Parallel usage of IPsec and other secure transport protocols..... | 17 | +| 4.5.3 Responder mode and Initiator/Responder mode support ..... | 17 | +| 4.6 CMPv2 ..... | 17 | +| 4.7 OAuth 2.0..... | 18 | +| 4.7.1 Overview ..... | 18 | +| 4.7.2 Basic Parametrization..... | 18 | +| 4.7.3 OAuth2.0 Access token API for O-RAN Elements and interfaces ..... | 20 | +| 4.8 LDAP ..... | 27 | +| 4.8.1 General requirements..... | 27 | +| 4.9 MACsec..... | 27 | +| 4.9.1 General requirements..... | 27 | +| 4.9.2 MACsec Profile ..... | 27 | +| 5 Cryptographic operations..... | 28 | +| 6 Secure File Transfer protocols..... | 30 | +| 6.1 General ..... | 30 | +| 6.2 SFTP..... | 30 | +| 6.2.1 General Requirements ..... | 30 | +| 6.3 FTPES ..... | 30 | +| 6.3.1 General Requirements ..... | 30 | +| 6.4 HTTPS..... | 30 | +| 6.4.1 General Requirements ..... | 30 | +| Annex A (normative): OpenAPI specifications ..... | 31 | +| A.1 OAuth2.0 API..... | 31 | +| A.1.1 Introduction ..... | 31 | +| A.1.2 OAuth 2.0 Access Token API ..... | 31 | + +| | | +|--------------------------------------------------------------------|----| +| Annex (informative): Change history/Change request (history) ..... | 34 | +|--------------------------------------------------------------------|----| + +# List of Figures + +| | | +|---------------------------------------------------------------------------|----| +| Figure 4.7.2.3-1: Access Token request process ..... | 19 | +| Figure 4.7.2.4-1: Service access request based on token verification..... | 20 | +| Figure 4.7.3.1-1: Resource structure for access token ..... | 21 | +| Figure 4.7.3.2-1: Access Token Request and Response..... | 22 | +| Figure 4.7.3.3-1: Service request using access token..... | 26 | + +# List of Tables + +| | | +|----------------------------------------------------------------------------------------------|----| +| Table 4.2.3-1: TLS Client and Server Certificate Profile..... | 13 | +| Table 4.7.3.1-1: Resources and methods overview of the Access Token API..... | 20 | +| Table 4.7.3.2.1-1: Data structures supported by the POST request body on this resource ..... | 22 | +| Table 4.7.3.2.1-2: Data structures supported by the POST Response Body on this resource..... | 22 | +| Table 4.7.3.2.1-3: Headers supported by the 200 Response Code on this resource..... | 23 | +| Table 4.7.3.2.2.1-1: Definition of type AccessTokenReq ..... | 23 | +| Table 4.7.3.2.2.2-1: Definition of type AccessTokenRsp..... | 24 | +| Table 4.7.3.2.2.3-1: Definition of type AccessTokenErr..... | 24 | +| Table 5-1: Cryptographic Operations for O-RAN..... | 28 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG11 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies security protocols as to be used for O-RAN compliant implementation. + +--- + +# 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] Void. +- [2] [IETF RFC 4252](#): "The Secure Shell (SSH) Authentication Protocol". +- [3] [OpenSSH](#): "OpenSSH Specifications". +- [4] Void. +- [5] [IANA](#): "Secure Shell (SSH) Protocol Parameters". +- [6] O-RAN ALLIANCE TS: "O-RAN Management Plane Specification". +- [7] Void. +- [8] [IANA](#): "Transport Layer Security (TLS) Parameters". +- [9] Void. +- [10] O-RAN ALLIANCE TS: "O-RAN Operations and Maintenance Interface Specification" . +- [11] [IETF RFC 6668](#): "SHA-2 Data Integrity Verification for the Secure Shell (SSH) Transport Layer Protocol". +- [12] [IETF RFC 8268](#): "More Modular Exponentiation (MODP) Diffie-Hellman (DH) Key Exchange (KEX) Groups for Secure Shell (SSH)". +- [13] [IETF RFC 8308](#): "Extension Negotiation in the Secure Shell (SSH) Protocol". +- [14] [IETF RFC 8332](#): "Use of RSA Keys with SHA-256 and SHA-512 in the Secure Shell (SSH) Protocol". +- [15] [IETF RFC 8709](#): "Ed25519 and Ed448 Public Key Algorithms for the Secure Shell (SSH) Protocol". +- [16] Void. +- [17] Void. +- [18] [IETF RFC 8446](#): "The Transport Layer Security Protocol (TLS) v1.3". +- [19] Void. +- [20] 3GPP TS 33.210: "Network Domain Security (NDS); IP network layer security". + +- [21] Void. +- [22] [IETF RFC 6066](#): "Transport Layer Security (TLS) Extensions: Extension Definitions". +- [23] Void. +- [24] [IETF RFC 6083](#): "Datagram Transport Layer Security (DTLS) for Stream Control Transmission Protocol (SCTP)". +- [25] Void. +- [26] 3GPP TS 33.310: Network Domain Security (NDS); Authentication Framework (AF)". +- [27] [IETF RFC 4301](#): "Security Architecture for the Internet Protocol". +- [28] 3GPP TS 33.401: "3GPP System Architecture Evolution (SAE); Security architecture". +- [29] 3GPP TS 33.501: "Security architecture and procedures for 5G system". +- [30] Void. +- [31] [IETF RFC 4303](#): "IP Encapsulating Security Payload (ESP)". +- [32] Void. +- [33] [IETF RFC 4306](#): "Internet Key Exchange (IKEv2) Protocol". +- [34] [IETF RFC 7296](#): "Internet Key Exchange Protocol Version 2 (IKEv2)". +- [35] [IETF RFC 6749](#): "The OAuth 2.0 Authorization framework". +- [36] [IETF RFC 7519](#): "JSON Web Token (JWT)". +- [37] [IETF RFC 7515](#): "JSON Web Signature (JWS)". +- [38] [IETF RFC 4210](#): "Internet X.509 Public Key Infrastructure Certificate Management Protocol (CMP)". +- [39] [IETF RFC 4211](#): "Internet X.509 Public Key Infrastructure Certificate Request Message Format". +- [40] [NIST](#): "Cryptographic Standards and Guidelines". +- [41] Void. +- [42] [NIST](#): "Digital Signature Standard (DSS) (FIPS PUB 186)". +- [43] Void. +- [44] [NIST](#): "Advanced Encryption Standard (AES) (FIPS PUB 197)". +- [45] Void. +- [46] Void. +- [47] [NIST](#): "SHA-3 Standard: Permutation-Based Hash and Extendable-Output Function (FIPS PUB 202)". +- [48] [NIST SP 800-131A Rev. 2](#): "Transitioning the Use of Cryptographic Algorithms and Key Lengths". +- [49] Void. +- [50] [IETF RFC 8017](#): "PKCS #1: RSA Cryptography Specifications Version 2.2". +- [51] Void. +- [52] Void. + +- [53] Void. +- [54] [IETF RFC 6125](#): "Representation and Verification of Domain-Based Application Service Identity within Internet Public Key Infrastructure Using X.509 (PKIX) Certificates in the Context of Transport Layer Security (TLS)". +- [55] [IETF RFC 7633](#): "X.509v3 Transport Layer Security (TLS) Feature Extension". +- [56] [CA/Browser Forum](#): "Baseline Requirements for the Issuance and Management of Publicly-Trusted Certificates". +- [57] Void. +- [58] Void. +- [59] Void. +- [60] [IETF RFC 7093](#): "Additional Methods for Generating Key Identifiers Values". +- [61] Void. +- [62] [IETF RFC 6960](#): "X.509 Internet Public Key Infrastructure Online Certificate Status Protocol - OCSP". +- [63] [IETF RFC 3647](#): "Internet X.509 Public Key Infrastructure Certificate Policy and Certification Practices Framework". +- [64] [IETF RFC 5280](#): "Internet X.509 Public Key Infrastructure Certificate and Certificate Revocation List (CRL) Profile". +- [65] [SFTP](#): "SFTP Standards". +- [66] [IETF RFC 4217](#): "Securing FTP with TLS (FTPES)". +- [67] 3GPP TS 28.532: "Management and orchestration; Generic management services". +- [68] 3GPP TS 28.537: "Management and orchestration; Management capabilities". +- [69] [IETF RFC 9110](#): "HTTP Semantics (HTTPS)". +- [70] [IETF RFC 4253](#): "The Secure Shell (SSH) Transport Layer Protocol". +- [71] [IETF RFC 9325](#): "Recommendations for Secure Use of Transport Layer Security (TLS) and Datagram Transport Layer Security (DTLS)". +- [72] [IETF RFC 3279](#): "Algorithms and Identifiers for the Internet X.509 Public Key Infrastructure Certificate and Certificate Revocation List (CRL) Profile". +- [73] ITU-T Recommendation X.509: "Information technology - Open Systems Interconnection - The Directory: Public-key and attribute certificate frameworks". +- [74] [IETF RFC 4511](#): "Lightweight Directory Access Protocol (LDAP): The Protocol". +- [75] [IETF RFC 4513](#): "Lightweight Directory Access Protocol (LDAP): Authentication Methods and Security Mechanisms". +- [76] [IETF RFC 9147](#): "The Datagram Transport Layer Security (DTLS) Protocol Version 1.3". +- [77] 3GPP TS 29.501: "5G System; Principles and Guidelines for Services Definition". +- [78] [IETF RFC 6750](#): "The OAuth 2.0 Authorization Framework: Bearer Token Usage". +- [79] IEEE Std 802.1AE-2018: "IEEE Standard for Local and metropolitan area networks — Media Access Control (MAC) Security". + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [i.2] Void. +- [i.3] Void. +- [i.4] [NIST SP 800-52 Rev.2](#): "Guidelines for the Selection, Configuration, and Use of Transport Layer Security (TLS) Implementations". +- [i.5] Void. +- [i.6] [BSI TR-02102-1](#): "Cryptographic Mechanisms: Recommendations and Key Lengths". +- [i.7] [NIST SP 800-38A](#): "Recommendation for Block Cipher Modes of Operation: Methods and Techniques". +- [i.8] [NIST SP 800-186](#): "Recommendations for Discrete Logarithm-based Cryptography: Elliptic Curve Domain Parameters". +- [i.9] [NIST SP 800-57 Part 1 Rev. 5](#): "Recommendation for Key Management: Part 1 – General". +- [i.10] Void. +- [i.11] [IETF RFC-7589](#): "Using the NETCONF Protocol over Transport Layer Security (TLS) with Mutual X.509 Authentication". + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +Void + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [i.1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [i.1]. + +| | | +|----|-------------------------| +| CA | Certification Authority | +|----|-------------------------| + +| | | +|---------|-------------------------------------| +| CMP | Certificate Management Protocol | +| DTLS | Datagram Transport Layer Security | +| DH | Diffie–Hellman | +| DPD | Dead Peer Detection | +| ESP | Encapsulating Security Payload | +| FTPES | Explicit SSL File Transfer Protocol | +| HTTPS | Hypertext Transfer Protocol Secure | +| IKE | Internet Key Exchange | +| IPsec | Internet Protocol Security | +| NAT | Network Address Translation | +| NE | Network Element | +| NETCONF | Network Configuration Protocol | +| PKI | Public Key Infrastructure | +| RA | Registration Authority | +| SA | Security Association | +| SFTP | SSH File Transfer Protocol | +| SPD | Security Policy Database | +| SSH | Secure Shell | +| TLS | Transport Layer Security | + +# 4 Security protocols specifications for O-RAN compliant implementation + +## 4.1 SSH + +### 4.1.1 General requirements + +O-RAN interfaces that implement authentication, confidentiality and integrity using SSH shall: + +- support SSHv2 [2] and [70]; +- disable by default cryptographically insecure ciphers as specified in clauses 4.1.2.1, 4.1.2.3, and 4.1.2.4; +- enable an O-RAN deployer to configure SSH to offer less secure ciphers using standard SSH configurations to enable backward compatibility with older SSH implementations; +- enable remote shell access only if required by the interface. If remote shell access is enabled, disable remote login as root or equivalent highest privileged user. Such access shall be limited to the local system console only. Root user shall not be allowed to login to the system remotely. + +Entities providing O-RAN components that support SSH for authentication, confidentiality or integrity shall: + +- stay current with SSH [5]; +- provide an upgrade path for changes to the SSH protocol and ciphers [5]. + +### 4.1.2 Required ciphers + +O-RAN requires the following ciphers when using SSH. For more information see [2], [5], [11], [12], [13], [14] and [15]. See Security clause 5.4 of the O-RAN Working Group 4 Management Plane Specification [6] for the M-plane mandated SSH ciphers. + +#### 4.1.2.1 Key agreement + +Note that this document uses the IANA cipher naming convention [5]. + +- Required + - a. ecdsa-sha2-nistp256 + - b. ecdsa-sha2-nistp384 + - c. ecdsa-sha2-nistp521 + - d. ssh-ed25519 +- Optional + - a. ssh-ed448 +- Shall not be implemented + - ssh-rsa + - ssh-dss + +#### 4.1.2.2 Symmetric algorithms for encrypting transferred data + +- Required + - a. aes256-gcm + - b. aes128-gcm + - c. aes256-ctr + - d. aes192-ctr + - e. aes128-ctr + +#### 4.1.2.3 Key exchange algorithms (KexAlgorithms) + +- Required + - a. ecdh-sha2-nistp521 + - b. ecdh-sha2-nistp384 + - c. ecdh-sha2-nistp256 + - d. diffie-hellman-group-exchange-sha256 + - e. curve25519-sha256 +- Shall not be implemented + - a. Diffie-hellman-group1-sha1 + +#### 4.1.2.4 Message authentication codes (MACs) + +- Required + - a. hmac-sha2-512-ctm + - b. hmac-sha2-512 + - c. hmac-sha2-256-ctm + +- d. hmac-sha2-256 +- e. umac-128 +- Shall not be implemented + - a. hmac-sha1 + +## 4.2 TLS + +### 4.2.1 General Requirements + +O-RAN interfaces that implement one-way authentication, mutual authentication, confidentiality, integrity, and replay protection using Transport Layer Security (TLS) shall be compliant with [18], allow negotiation of both TLS 1.2 [18] and TLS 1.3 [18], and not allow negotiation to any version of SSL or any version of TLS below 1.2. Further, O-RAN interfaces using TLS may allow TLS 1.2 to be disabled by configuration ([i.4], section 3.1). + +NOTE: In one-way TLS the server sends a Certificate message, a CertificateVerify message, and a Finished message to the client so that the client can authenticate the server by validating the server's certificate and possession of the private key associated with the certificate. In mutual TLS (mTLS) the server sends a CertificateRequest message indicating that the client must authenticate itself with a certificate. The server then sends a Certificate message, a CertificateVerify message, and a Finished message to the client. Upon receiving the server's messages, the client responds with its Authentication messages, namely Certificate and CertificateVerify, and Finished. For full details of the authentication steps in TLS see [18]. + +See clause 5.4 of the O-RAN Working Group 4 Management Plane Specification for the Open Fronthaul M-plane mandated TLS requirements [6]. + +#### 4.2.1.1 Void + +Void + +### 4.2.2 TLS Protocol Profile + +TLS 1.2 used on all interfaces except the Open Fronthaul interfaces shall support the TLS 1.2 profiles as defined by 3GPP TS 33.210 [20] clause 6.2.3. + +TLS 1.3 used on all interfaces except the Open Fronthaul interfaces shall support the TLS 1.3 profiles as defined by 3GPP TS 33.210 [20] clause 6.2.2. + +Use of a cipher suite in TLS shall be configurable. + +Additional cipher suites recommended by IANA [52] may be supported. + +### 4.2.3 TLS Certificate Profile + +The present clause addresses the certificate profile requirements for the TLS entities that may behave either as client, server, or both. The structure of the TLS certificate profile described in this clause under Table 4.2.3-1 provides requirements based on the 3GPP – TS 33.310 [26], CA-Browser Forum [56] and NIST Special Publication 800-52.2 [i.4]. The TLS entity certificate profile shall be applied to all nodes and interfaces that use the TLS protocol for secured communication in the O-RAN network except the Open Fronthaul interfaces. + +- The TLS entity certificates shall adhere to the certificate profile outlined in the Table 4.2.3-1, based on their respective roles. +- The CA responsible for handling the certificate signing request shall ensure compliance in accordance with the certificate profile specified in clause 4.2.3. +- The common rules for all certificates defined in 3GPP- TS 33.310 [26], clause 6.1.1 and 6.1.3a shall apply. +- The CA-Browser Forum [56] has the following requirement for the certificate operational and key usage periods. Certificates issued on or after 1 September 2020 shall not have a Validity Period greater than 397 days. +- Subject: The subject field follows the X.501 type Name as defined in clause 4.1.2.6 of IETF RFC 5280 [64]. +- Certificate Policies: Certificate policies shall be crafted using the guidelines defined in IETF RFC 3647 [63]. +- subjectAltName shall (for TLS server certificates) contain at least one FQDN(Hostname) and shall not contain only IP Address as described in IETF RFC 6066 [22]. As per IETF RFC 6125 [54], an application service shall be identified by a name or names carried in the subject field (i.e., a CN-ID) and/or in one of the following identifier types within subjectAltName entries (DNS-ID, SRV-ID, URI-ID). +- Optional and non-critical TLS Feature Extension: IETF RFC 7633 [55] defines a certificate extension that indicates that clients expect stapled OCSP responses with a value of “status\_request (5)” for the certificate and aborts the handshake ("hard-fail") if such a response is not available. As per IETF RFC 9325 [71] TLS servers should support the following as a best practice: OCSP IETF RFC 6960 [62] and OCSP stapling using the status\_request extension defined in IETF RFC 6066 [22]. The exact mechanism for embedding the status\_request extension differs between TLS 1.2 and TLS 1.3. As a matter of local policy, server operators may request that CAs issue must-staple IETF RFC 7633 [55] certificates for the server and/or for client authentication. +- Extensions: Mandatory Critical Key Usage + - digitalSignature for both TLS client and Server certificates. This applies for RSA signature certificate, ECDSA signature certificate, or DSA signature certificate. + - When using RSA IETF RFC 3279 [72] with TLS 1.2, the keyEncipherment shall be set. + - When using DH [72] or ECDH [72] with TLS 1.2, the keyAgreement shall be set. + +As per the certificate profile requirements described in clause 4.2.3 and guidelines outlined in IETF RFC 5280 [64], the following table captures the certificate profile for the TLS entity that may behave as a client, server or both. + +**Table 4.2.3-1: TLS Client and Server Certificate Profile** + +| ORAN TLS Client and Server Certificate Profile | | +|------------------------------------------------|---------------------------------------------------------------------------------------------| +| Version | v3 | +| Serial Number | Unique Positive Integer in the context of the issuing CA | +| Subject | EXAMPLE: (C=), O=, CN=. | +| Validity Period | 1 year or less | +| Signature | See 3GPP TS 33.310 [26], clause 6.1.1 for the list of supported signature algorithms. | + +| Subject Public Key Info | | See 3GPP TS 33.310 [26], clause 6.1.1 for the list of supported public key types. | | +|-------------------------|-----------|-----------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Extensions | Mandatory | Criticality | Value | +| keyUsage | TRUE | TRUE | digitalSignature for TLS clients and servers | +| extendedKeyUsage | FALSE | FALSE | id-kp-clientAuth TLS clients | +| | | | id-kp-serverAuth for TLS servers | +| | | | Entities that may be both client and server will have both OIDs set. | +| certificatePolicies | FALSE | FALSE | If added, then, it should be populated with a CP object identifier(OID). These OIDs correspond to specific policies established by the certificate issuer | +| authorityKeyIdentifier | FALSE | FALSE | This is same as the subjectKeyIdentifier of the Issuer's certificate. CA utilizes the method as defined in clause 2 of IETF RFC 7093 [60]. | +| subjectKeyIdentifier | FALSE | FALSE | This is calculated by the issuing CA utilizing method as defined in clause 2 of IETF RFC 7093 [60]. | +| cRLDistributionPoint | TRUE | FALSE | distributionPoint
    According to IETF RFC 5280 [64] this indicates if the CRL is available for retrieval using access protocol and location with HTTP URI or LDAP. | +| subjectAltName | TRUE | TRUE | Multiple subjectAltNames are permitted as defined above | +| authorityInfoAccess | FALSE | FALSE | id-ad-caIssuers | + +| | | | | +|-----------------------|-------|-------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | According to IETF RFC 5280 [64] id-ad-calssuers describes the referenced description server and the access protocol and location, for example, using one or multiple HTTP and/or LDAP URIs. The referenced CA issuers description is intended to aid certificate users in the selection of a certification path that terminates at a point trusted by the certificate user | +| | | | id-ad-ocsp
    According to IETF RFC 5280 [64] id-ad-ocsp defines the location of the OCSP responder using HTTP URI. | +| TLS feature extension | FALSE | FALSE | id-pe-tlsfeature: "status_request(5)"
    This can be used according to IETF RFC 7633 [55] to prevent downgrade attacks that are not otherwise prevented by the TLS protocol; IETF RFC 7633[55] also defines a certificate extension that indicates that clients expects stapled OCSP responses with a value of "status_request(5) " for the certificate and aborts the handshake ("hard-fail") if such a response is not available. | + +## 4.3 Support NETCONF over secure Transport + +TLS requirements for use with NETCONF on the O1 interface [10] are specified in clause 4.2. + +TLS requirements for use with NETCONF on the Open Fronthaul M-plane are specified in clause 5.4 of the O-RAN WG4 Management Plane Specification [6]. + +## 4.4 DTLS + +### 4.4.1 General requirements + +O-RAN interfaces that implement mutual authentication, integrity protection, replay protection and confidentiality protection using Datagram Transport Layer Security (DTLS) shall: + +- support DTLS 1.2 [76]; +- support DTLS for Stream Control Transmission Protocol [24]; + +and should support DTLS 1.3 [76]. + +DTLS 1.0 shall not be supported. + +NOTE 1: IETF RFC 6083 [24] specifies a user message limit of approximately 16k bytes, which shall be compared to the unlimited user message size that exists when SCTP is used without DTLS. There could be applications messages exceeding the limit, preventing the use of DTLS over SCTP, so enforcing unsecured SCTP. + +### 4.4.2 DTLS Protocol Profile + +For DTLS 1.2, all TLS 1.2 related provisions in clause 4.2.2 shall apply. + +For DTLS 1.3, all TLS 1.3 related provisions in clause 4.2.2 shall apply. + +### 4.4.3 Certificate Profile + +Certificate profile defined in clause 4.2.3 shall apply. + +## 4.5 IPsec + +### 4.5.1 Overview + +O-RAN and 3GPP interfaces that implement authentication, confidentiality and integrity using IPsec shall support IPsec according to [27]. The supported IPsec capabilities in this clause follow [20] for interworking purposes and further apply requirements given in [26], [28], and [29]. + +#### 4.5.1.1 Supported IPsec capabilities + +Services that SHALL be supported (see also [29], section 9.8.2): + +- Confidentiality, can be enabled/disabled (via ENCR\_NULL) +- integrity protection, always enabled +- data origin authentication, always enabled +- anti-replay protection, can be enabled/disabled +- extended sequence numbers, can be enabled/disabled + +Protocol that SHALL be supported: ESP ([31], as profiled by [20]) + +- IPsec mode: Tunnel mode +- Copying the DSCP value from the inner IP-header to the outer IP-header for encrypted packets +- for encrypted packets the DSCP value of the inner packet will be copied to the outer packet +- NAT traversal + +ESP encryption transforms that SHALL be supported (including authenticated encryption transforms, see also [20], section 5.3.3). ESP authentication transforms that SHALL be supported according to [20], subsection 5.3.4. + +- IKE endpoint Identification that SHALL be supported, according to [26], subsection 6.2.1b: IP address +- Fully Qualified domain name (FQDN) (if DNS is supported) + +Authentication that SHALL be supported: + +- X.509v3 digital certificates provided by a Certificate Authority solution + +Authentication that MAY be supported: + +- Pre-shared Keys + +NOTE: Pre-shared keys should not be used. + +Key exchange that SHALL be supported: + +- IKEv2 [33] profile as described in [26] +- certificate-based authentication according to [26] +- certificates according to the profile described by [26] +- DH group 19 +- (Optional) DH group 20 + +Security Association multiplicity that SHALL be supported: + +- multiple IKE SAs (multiple IPsec tunnels) +- multiple IPsec SAs +- multiple IPsec SAs per IPsec tunnel + +IKE SA(s) and IPSEC SA(s) SHALL be regularly re-established. + +- When the full sequence number space of an IPSEC SA(s) is used, the transmission for that SA SHALL stop. +- 4.5.1.1.10 Dead-Peer-Detection (DPD) SHALL be supported as defined in [34]. Each node SHALL support a traffic narrowing function for the traffic selector ([34]): If the traffic selector notified from the peer (e.g. Security GW or neighbouring node) is wider than the Local/Remote Address range in the SPD information set on the node side, the peers set the traffic selector values to the narrower range. + +### 4.5.2 Parallel usage of IPsec and other secure transport protocols + +Implementations SHALL support IPsec configuration with one or more dedicated connections in parallel with other secure transport protocols. + +EXAMPLE: It should be possible to run SSH or TLS connections within an IPsec tunnel or in parallel to IPsec tunnel(s). + +### 4.5.3 Responder mode and Initiator/Responder mode support + +Implementations SHALL support a configurable option per IKE Security Association to use "Responder mode" instead of "Responder/Initiator mode". + +Responder mode is applied to IKE SA establishment only. The introduction of "Responder mode" does not change the IKE SA rekeying behavior: Each node shall be able to operate as initiator and responder in IKE\_SA rekeying. + +## 4.6 CMPv2 + +Certificate Management Protocol version 2 (CMPv2) is based on Internet X.509 Public Key Infrastructure (PKI) Certificate Management Protocol (CMP) specified in IETF RFC 4210 [38] and 4211 [39]. + +3GPP TS 33.310 [26] specifies the use of CMPv2 used by base stations to obtain an operator-signed certificate using a secured communication based on the vendor-signed certificate in the base station and a vendor root certificate pre-installed in the CA/RA server. + +Certificates may be installed at initial system initialization or obtained through certificate enrolment with the operator's PKI. Certificate enrolment may be supported with the CMPv2 protocol between the Network Element (NE) and the operator's CA as defined in 3GPP TS 33.310 [26]. A PNF that supports CMPv2 shall use the CMPv2 profile defined in 3GPP TS 33.310 [26], clause 9.5. The CA/RA server may include the trust anchor for the operator issued certificate and the appropriate certificate chains in the initialization response message. + +## 4.7 OAuth 2.0 + +### 4.7.1 Overview + +The authorization framework described in clause 4.7 of the present document uses the OAuth 2.0 framework as specified in IETF RFC 6749 [35]. It allows the service producers to authorize the requests from service consumers, and the service consumers to obtain authorization credentials (“token endpoint”). + +Interfaces requiring the use of OAuth 2.0 for authorization purposes shall support the functionality according to clause 4.7 of the present document. + +Following options have been introduced to guarantee interoperability and align with the existing OAuth 2.0 authorization framework in 3GPP [29] (i.e., Service Based Architecture). + +### 4.7.2 Basic Parametrization + +#### 4.7.2.1 General + +Client access token authorization grants shall be supported with type Client Credentials Grant, as described in 4.4 of IETF RFC 6749 [35]. Mutual TLS authentication, as specified in the present document (clause 4.2.1), is the mechanism selected by O-RAN for this security procedure. + +In addition, still aligned with Client Credential Grant as described in section 4.4. of IETF RFC 6749 [35], Client Id and Client Secret may be supported for client authentication. In this case, one-way TLS may be used (certificate on server side). + +Access tokens shall be JSON Web Tokens (JWT) as described in IETF RFC 7519 [36] and shall be secured with digital signatures based on JSON Web Signature (JWS) as described in IETF RFC 7515 [37]. + +The ‘scope’ attribute as described in clause 3.3 of IETF RFC 6749 [35] shall be used to specify the allowed services per type of service producer. A more granular level of authorization may be defined by adding additional scope information with the token (e.g., to authorize specific operations, or access to particular resources or datasets), which requires to be verified by the service producer. + +OAuth 2.0 roles, as defined in clause 1.1 of IETF RFC 6749 [35], are as follows: + +- OAuth 2.0 Authorization server: new security function in O-RAN architecture; or provided by existing OAuth 2.0 infrastructure in the network. +- OAuth 2.0 client: every API service consumer in O-RAN system (e.g., rApp, xApps) +- OAuth 2.0 resource owner/server: every API service producer in O-RAN system (e.g., Near-RT RIC platform) + +#### 4.7.2.2 Registration process + +OAuth 2.0 resource servers (API service producers) shall be registered with the OAuth 2.0 Authorization server. Service producers may include additional scope information related to specific allowed service operations and resources per client type. + +Before initiating the authorization protocol, OAuth 2.0 clients shall be registered with the OAuth 2.0 Authorization server. To achieve that, information about the service consumer instance and its type shall be made available in the OAuth 2.0 Authorization server. The registration process is subject to implementation procedures of the operator, with the following consideration on authentication procedure: + +OAuth 2.0 clients shall be capable to authenticate securely with the authorization server and client type shall be “confidential” as specified in clause 2.1 of IETF RFC 6749 [35]. + +Strong authentication mechanisms based on digital certificates shall be supported. + +In addition, client authentication mechanism based on client Id and Client Secret may be supported. + +#### 4.7.2.3 Access Token request process + +##### 4.7.2.3.0 Introduction + +After TLS mutual authentication procedure between the OAuth 2.0 client and OAuth 2.0 Authorization server, or one-way TLS authentication with server certificate and client authentication based on Client Id and Client Secret has been executed, the Authorization server exposes a ‘Token Endpoint’ where the Access Token request service can be requested by OAuth 2.0 client. + +The following procedure depicts the procedure of the OAuth 2.0 client to obtain an access token from the OAuth 2.0 authorization server. + +![Sequence diagram showing the Access Token request process between an OAuth 2.0 Client and an OAuth 2.0 Authorization Server.](29e779cca60cb3268691f257b39a1c79_img.jpg) + +``` + +sequenceDiagram + participant Client as OAuth 2.0 Client + participant Server as OAuth 2.0 Authorization Server + Client->>Server: 1.AccessToken_Get Request +(Expected service name(s) and producer type, +client type, client id, ...) + Note over Server: 2. +Check whether the +client (API service +consumer) is +authorized. +If client is authorized, +generate an access +token. + Server-->>Client: 3. AccessToken_Get Response +(expiration time, access_token) + +``` + +Sequence diagram showing the Access Token request process between an OAuth 2.0 Client and an OAuth 2.0 Authorization Server. + +**Figure 4.7.2.3-1: Access Token request process** + +The OAuth 2.0 Client shall request an access token from the OAuth 2.0 Authorization server. For this operation the client shall send a HTTP POST request to the authorization server (‘Token endpoint’), as described in IETF RFC 6749 [35], clause 3.2. The message, i.e., the body of the HTTP POST request, shall include the identifier of the client instance making the request, the ‘scope’ parameter indicating the expected services, and optionally additional scope information with more granular information about resources and operations on the resources, and optionally the type of client (‘confidential’) and the expected OAuth 2.0 resource owner/server. The message may include as well information referring to instance(s) of specific resource owner(s)/server(s) if required. + +##### 4.7.2.3.1 Server requirements + +- The OAuth 2.0 Authorization server shall verify that the input parameters in the access token (e.g., client type) match with the corresponding ones in the public certificate of the client, or those in the client profile previously registered. +- If the client is authorized, the Authorization server shall generate an access token with appropriate scope as defined in clause 3.3 of IETF RFC6749[35] included. +- The Authorization server shall digitally sign the generated access token based on a private key as described in IETF RFC 7515 [37]. If the client is not authorized, the Authorization server shall not issue an access token to that client. If the authorization is successful, the Authorization server shall send the access token to the client (‘200 OK’), otherwise it shall reply based on OAuth 2.0 error response defined in IETF RFC 6749 [35]. +- The success response should include in addition the expiration time for the token as indicated in IETF RFC 6749 [35]. +- The response shall include information to identify the resource owner(s)/server(s) if they differ from the related information included in the token request. + +#### 4.7.2.4 Service access request based on token verification + +Once the client is in possession of a valid access token, it may proceed with the request of service access towards the service producer (OAuth 2.0 resource owner/server). + +![Sequence diagram showing the service access request based on token verification. The OAuth 2.0 Client sends a service request (access token) to the OAuth 2.0 Resource Owner/Server. The Resource Owner/Server verifies the integrity and claims in the access token. If successful, it executes the requested service and sends a service response back to the Client.](6e52e241790620ef6fb7dcc1fcba752b_img.jpg) + +``` + +sequenceDiagram + participant Client as OAuth 2.0 Client + participant Server as OAuth 2.0 Resource Owner/Server + Client->>Server: 1. Service request (access token) + Note over Server: 2. Verify integrity and claims in the access token. If successful, execute the requested service + Server-->>Client: 3. Service response + +``` + +Sequence diagram showing the service access request based on token verification. The OAuth 2.0 Client sends a service request (access token) to the OAuth 2.0 Resource Owner/Server. The Resource Owner/Server verifies the integrity and claims in the access token. If successful, it executes the requested service and sends a service response back to the Client. + +**Figure 4.7.2.4-1: Service access request based on token verification** + +1. The OAuth 2.0 client requests service from the OAuth 2.0 resource owner/server. The OAuth 2.0 client shall include the access token in the request. The OAuth 2.0 client and OAuth 2.0 resource owner/server shall authenticate each other via mutual TLS, as defined in the present document (clause 4.2.1). In addition, one-way TLS authentication with certificate only on server side may be supported, as defined in the clause 4.2.1. +2. The OAuth 2.0 resource owner/server shall verify the token: + - i. It ensures the integrity of the token by verifying the signature using the OAuth 2.0 Authorization server's public key. + - ii. If the integrity check is successful, the OAuth 2.0 resource owner/server shall verify the claims. +3. If the verification is successful, the OAuth 2.0 resource owner/server shall execute the requested service and respond back to the OAuth 2.0 client. Otherwise, it shall send a proper error response. If the HTTP protocol is used, that error response shall be based on the OAuth 2.0 error response defined in IETF RFC 6749 [35]. + +### 4.7.3 OAuth2.0 Access token API for O-RAN Elements and interfaces + +#### 4.7.3.1 Introduction + +This API allows the API Consumer to request an access token based on the procedures for "Access Token request process" as defined in clause 4.7.2.3. + +The API version number format shall follow the definitions in clause 4.3.1.1 of 3GPP TS 29.501 [77]. The MAJOR version field shall be 1, the MINOR version field shall be 0 and the PATCH version field shall be 0. Consequently, the URI path segment shall be set to "v1". + +The API is under development and consequently the API version shall include the pre-release version "alpha.1". + +For the general token endpoint for O-RAN RESTful service APIs, the URI structure should follow the provisions specified below, with the resource URI variable set to "oauth2". + +The resources and methods overview of the access token API are addressed in Table 4.7.3.1-1 and shown in Figure 4.7.3.1-1. + +**Table 4.7.3.1-1: Resources and methods overview of the Access Token API** + +| Resource Name | Resource URI | HTTP method | Service Operation | +|---------------|--------------|-------------|----------------------| +| Access Token | .../token | POST | Access token request | + +{apiRoot}/oauth2/ + +![Diagram showing the resource structure for access token. A vertical line from the text above connects to a horizontal line, which then points to a box containing '/token'.](d995e216ca151dc1a054401a6e3b8c0b_img.jpg) + +Diagram showing the resource structure for access token. A vertical line from the text above connects to a horizontal line, which then points to a box containing '/token'. + +**Figure 4.7.3.1-1: Resource structure for access token** + +#### 4.7.3.2 Service operations for access token request + +The service operation is defined in IETF RFC 6749 [35] and represented in Figure 4.7.3.2-1. + +In the present document, only the use of the "Client credentials grant type" (see clauses 1.3.4 and 4.4 of IETF RFC 6749 [35]) is supported. + +``` + +@startuml + !pragma teoz true + skinparam ParticipantPadding 5 + skinparam BoxPadding 10 + skinparam defaultFontSize 12 + skinparam lifelineStrategy solid + autonumber + + participant "API Consumer" as AC + participant " Authorization Server " as AS + + AC->>AS: POST .../token (AccessTokenReq) + AS->>AS: validate-credentials + + alt Success + AS->>AC: 200 Ok (AccessTokenRes) + else Failure + AS->>AC: 400 Bad Request (AccessTokenErr) + end +end + +``` + +![Sequence diagram for Access Token Request and Response. The diagram shows an API Consumer sending a POST request to the Authorization Server. The server then validates credentials. An alternative block shows two possible responses: a 200 OK response on success or a 400 Bad Request response on failure.](03e21275497df8922a164ac052228b6d_img.jpg) + +``` + +sequenceDiagram + participant AC as API Consumer + participant AS as Authorization Server + AC->>AS: 1 POST .../token (AccessTokenReq) + AS->>AS: 2 validate-credentials + alt [Success] + AS-->>AC: 3 200 Ok (AccessTokenRes) + else [Failure] + AS-->>AC: 4 400 Bad Request (AccessTokenErr) + end + +``` + +Sequence diagram for Access Token Request and Response. The diagram shows an API Consumer sending a POST request to the Authorization Server. The server then validates credentials. An alternative block shows two possible responses: a 200 OK response on success or a 400 Bad Request response on failure. + +**Figure 4.7.3.2-1: Access Token Request and Response** + +1. The API Consumer sends an HTTP POST request to Authorization Server to request the access token from the Token Endpoint. +2. The Authorization Server authenticates the client as specified in clause 4.4.2 of IETF RFC 6749 [35] and validates the request as implied in clause 4.4.3 of IETF RFC 6749 [35]. +3. On success, the Authorization Server returns a “200 OK” HTTP response along with an access token response structure. +4. On failure, the Authorization Server returns a “400 Bad Request” HTTP response and the message content contains additional error information. + +##### 4.7.3.2.1 Resource Standard Methods + +The POST method and its request and response parameters are specified in IETF RFC 6749 [35]. + +This information is reproduced using the O-RAN scheme for RESTful API definitions below, with the request data structure represented in Table 4.7.3.2.1-1, the response data structures and response codes represented in Table 4.7.3.2.1-2 and the HTTP headers represented in Table 4.7.3.2.1-3. + +**Table 4.7.3.2.1-1: Data structures supported by the POST request body on this resource** + +| Data Type | P | Cardinality | Description | +|----------------|---|-------------|------------------------------------------------------------------------------------------------------------------------------------| +| AccessTokenReq | M | 1 | As content specified in IETF RFC 6749 [35]. See also clause 4.7.3.1.2.1. The content type is " application/x-www-form-urlencoded". | + +**Table 4.7.3.2.1-2: Data structures supported by the POST Response Body on this resource.** + +| Data Type | P | Cardinality | Response codes | Description | +|----------------|---|-------------|-----------------|------------------------------------------------------------------------------------------------------------------| +| AccessTokenRsp | M | 1 | 200 OK | As content specified in IETF RFC 6749 [35]. See also clause 4.7.3.1.2.2. The content type is "application/json". | +| AccessTokenErr | M | 1 | 400 Bad request | As content specified in IETF RFC 6749 [35]. See also clause 4.7.3.1.2.3. The content type is "application/json". | + +**Table 4.7.3.2.1-3: Headers supported by the 200 Response Code on this resource.** + +| Name | Data type | P | Cardinality | Description | +|---------------|-----------|---|-------------|---------------------------------------------| +| Cache-control | string | M | 1 | As content specified in IETF RFC 6749 [35]. | +| Pragma | string | M | 1 | As content specified in IETF RFC 6749 [35]. | + +##### 4.7.3.2.2 Data Model + +The following clauses represent the message content to be used by the OAuth2.0 access token API as O-RAN data types in line with the provisions in IETF RFC 6749 [35]. + +###### 4.7.3.2.2.1 Data type: AccessTokenReq + +The AccessTokenReq data type represents an access token request to the Authorization Server. Its attributes are defined by IETF RFC 6749 [35] and reproduced in Table 4.7.3.2.2.1-1. + +**Table 4.7.3.2.2.1-1: Definition of type AccessTokenReq** + +| Attribute Name | Data type | P | Cardinality | Description | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------|---|-------------|---------------------------------------------------------------------------------------------------------------------------------------------------| +| grant_type | string | M | 1 | As content specified in clause 4.4.2 of IETF RFC 6749 [35].

    In the present document, the only allowed value shall be "client_credentials". | +| client_id | string | C | 0..1 | As content specified in IETF RFC 6749 [35]. See NOTE. | +| client_secret | string | C | 0..1 | As content specified in IETF RFC 6749 [35]. See NOTE. | +| scope | string | O | 0..1 | As content specified in in clause 4.4.2 of IETF RFC 6749 [35]. | +| NOTE: As specified in clause 2.1 of IETF RFC 6749 [35], there are two options for authenticating the clients to the Authorization Server: HTTP basic authentication and access token request message content. The attributes "client_id" and "client_secret" shall be absent if HTTP basic authentication is used to convey the client credentials as per section 2.3.1 of IETF RFC6749 [35] and shall be present otherwise. | | | | | + +###### 4.7.3.2.2.2 Data type: AccessTokenRsp + +The AccessTokenRsp data type represents an access token response from the Authorization Server. Its attributes are defined by IETF RFC 6749 [35] and reproduced in table 4.7.3.2.2.2-1. + +**Table 4.7.3.2.2.2-1: Definition of type AccessTokenRsp.** + +| Attribute Name | Data type | P | Cardinality | Description | +|----------------|-----------|---|-------------|-----------------------------------------------------------| +| access_token | string | M | 1 | As content specified in clause 5.1 of IETF RFC 6749 [35]. | +| token_type | string | M | 1 | As content specified in clause 5.1 of IETF RFC 6749 [35]. | +| expires_in | integer | O | 0..1 | As content specified in clause 5.1 of IETF RFC 6749 [35]. | +| scope | string | O | 0..1 | As content specified in clause 5.1 of IETF RFC 6749 [35]. | + +###### 4.7.3.2.2.3 Data type: AccessTokenErr + +The AccessTokenErr data type represents an access token error response from the Authorization Server. Its attributes are defined by IETF RFC 6749 [35] and reproduced in table 4.7.3.2.2.3-1. + +**Table 4.7.3.2.2.3-1: Definition of type AccessTokenErr** + +| Attribute Name | Data type | P | Cardinality | Description | +|-------------------|-----------|---|-------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| error | string | M | 1 | As content specified in clause 5.2 of IETF RFC 6749 [35], the following values are valid: "invalid_request", "invalid_client, invalid_grant", "unauthorized_client", "unsupported_grant_type", "invalid_scope." | +| error_description | string | O | 0..1 | As content specified in clause 5.2 of IETF RFC 6749 [35]. | +| error_uri | string | O | 0..1 | As content specified in clause 5.2 of IETF RFC 6749 [35]. | + +#### 4.7.3.3 Service operations for Service access request + +The service operation is as follows: + +``` + +@startuml + !pragma teoz true + skinparam ParticipantPadding 5 + skinparam BoxPadding 10 + skinparam defaultFontSize 12 + skinparam lifelineStrategy solid + autonumber + + participant "API Consumer" as AC + participant " API Producer " as AP + + AC->>AP: GET.../(access_token) + AP->>AP: validate(access_token) + + alt Authorized + AP->>AC: 200 Ok + else Access token invalid + AP->>AC : 401 Unauthorized + else Insufficient scope + AP->>AC : 403 Forbidden + else Other error response + AP->>AC: 4xx/5xx Error response + end +end + +``` + +![Sequence diagram for Service request using access token](a4a9ce2dd165f342247cbb46ac873e29_img.jpg) + +``` + +sequenceDiagram + participant AC as API Consumer + participant AP as API Producer + AC->>AP: 1 GET.../(access_token) + AP->>AP: 2 validate(access_token) + alt [Authorized] + AP-->>AC: 3 200 Ok + else [Access token invalid] + AP-->>AC: 4 401 Unauthorized + else [Insufficient scope] + AP-->>AC: 5 403 Forbidden + else [Other error response] + AP-->>AC: 6 4xx/5xx Error response + end + +``` + +The diagram illustrates the service request process using an access token. It shows the interaction between an API Consumer and an API Producer. The API Consumer sends a GET request with an access token. The API Producer validates the token. Depending on the validation result, the API Producer returns a response: 200 Ok (Authorized), 401 Unauthorized (Access token invalid), 403 Forbidden (Insufficient scope), or a 4xx/5xx Error response (Other error response). + +Sequence diagram for Service request using access token + +**Figure 4.7.3.3-1: Service request using access token** + +1. The API Consumer shall access the protected resources by using access token for the service API being invoked as shown in Figure 4.7.3.2-1. The access token shall be included in the request as an HTTP header field as specified in clause 2.1 of IETF RFC 6750 [78]. +2. The API Producer shall validate the access token and ensure that it has not expired and that its scope covers the requested resource. +3. If the token validation is successful, the API Producer shall allow access for the actual resource with the actual request and its parameters. The API Producer shall return the HTTP response as defined for the service API being invoked. +4. If the token validation fails due to invalid token or expired token, the API Producer shall return "401 Unauthorized" in line with the provisions in clause 3 of IETF RFC 6750 [78]. +5. If the token validation is failed due to insufficient access rights to access the resource, the API Producer shall return "403 Forbidden" in line with the provisions in clause 3 of IETF RFC 6750 [78]. +6. In case of any other error, the API Producer shall return the appropriate error as defined by the service API. + +## 4.8 LDAP + +### 4.8.1 General requirements + +LDAP, or the Lightweight Directory Access Protocol, is a widely adopted, unbiased standardized communication protocol that enables the interaction and management of distributed directory data via an IP network. This protocol plays a crucial part in the creation of both intranet and internet applications, as it facilitates the sharing of detailed information about various resources, such as users, systems, networks, services, and applications, across the entire network. + +O-RAN interfaces that implement Lightweight Directory Access Protocol (LDAP) shall: + +- support LDAP version 3 as specified in [74] and LDAP with StartTLS as specified in [75]. +- not support previous versions of LDAP. + +StartTLS operation shall be initiated prior to any other LDAP operation and all LDAP data shall be sent only after successful establishment of TLS connection. Requirements for TLS in clause 4.2 shall apply. + +## 4.9 MACsec + +### 4.9.1 General requirements + +The O-RAN interfaces that implement authentication, confidentiality and integrity using MACsec shall support MACsec capabilities according to **IEEE Std 802.1AE-2018** [79]. + +### 4.9.2 MACsec Profile + +The O-RAN interfaces using MACsec shall support the mandatory cipher suites as specified in IEEE Std 802.1AE-2018 [79] clause 14, Table 14-1—MACsec Cipher Suites. + +# 5 Cryptographic operations + +The following table outlines the main cryptographic operations involved in the protection of (1) App/VNF/CNF packages for ensuring their integrity, authenticity and confidentiality (for sensitive artifacts) during delivery, onboarding, and instantiation phases, (2) the communication channel over O-RAN interfaces in terms of authenticity, confidentiality and integrity, and (3) the stored assets within O-RAN system. It contains the allowed list of algorithms, key sizes and standards according to BSI [i.6] and NIST [40], [48], [i.9] cryptographic guidelines. + +**Table 5-1: Cryptographic Operations for O-RAN** + +| Cryptographic operations | Algorithms | Key sizes | Applicable standards | Usage | Note | +|---------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------| +| Signature generation and verification | RSASSA-PSS
    RSA_PKCS1_V1_5 | >= 2048-bits | FIPS 186 [42] | For ensuring the integrity and authenticity of Apps/VNF/CNF packages during delivery, onboarding, and instantiation phases | Existing code should use PKCS #1 v1.5 padding mode for compatibility only. Use of null padding is not recommended. | +| Signature generation and verification | ECDSA NIST-approved curves (P-256, P-384, or P-521) | >= 256-bits | FIPS 186 [42], SP 800-186 [i.7] | | Parameter key size for DSA shall not allow the following combination:
    Bit lengths of L and N parameters
    L = 2048, N = 224 (BSI TR-02102-1) | +| Symmetric Encryption/Decryption | AES_128, AES_192 and AES_256 | 128, 192 and 256 bits | FIPS 197 [44], SP 800-38 [i.8] (operation modes) | For ensuring the confidentiality of sensitive artifacts | | +| Asymmetric Encryption/Decryption | RSAES-OAEP | >= 2048-bits | IETF RFC 8017 [50] | | | +| Hashing | SHA-2 family (SHA-224, SHA-256, SHA-384, SHA-512, SHA-512/224 and SHA-512/256)
    SHA-3 family (SHA3-224, SHA3-256, SHA3-384, and SHA3-512) | | FIPS 180 [44] for SHA2
    FIPS 202 [47] for SHA3 | For ensuring the integrity of Apps/VNF/CNF packages | | + +The signature operation shall involve X.509-based PKI certificates [74]. + +The following recommendations should be considered: + +- For the protection of cryptographic keys, Hardware Security Modules, or HSMs, should be used. +- Along with HSMs, the principle of least privilege should be used with keys, to ensure only users who need the key have access to it. + +- In case a legacy system doesn't support ECDSA, RSA signing algorithms should be used instead. Otherwise, the use of the Elliptic curve signing algorithms is recommended. +- If libraries or frameworks are in use that don't support PSS padding scheme, one of the RSA PKCS1 algorithms should be used instead. Otherwise, the use of one of the RSA PSS algorithms is recommended. +- In general, the largest key size available for an algorithm family should be used: + - For RSA, the largest supported key size is 4096 bits. + - For ECDSA, the largest supported key size is 512 bits. + - For AES, the largest supported key size is 256 bits. + +# 6 Secure File Transfer protocols + +## 6.1 General + +File Transfer management is required in several O-RAN use cases, e.g. for export of log files. + +An O-RAN architectural element that implements file management shall support at least one of these secure file transfer protocols: SFTP, FTPES, HTTPS. This is aligned with, for example, how 3GPP specifies File Management in [67] and [68] + +SFTP is authenticated with username/password, SSH keys or X.509 certificates. FTPES is authenticated with X.509 certificates. HTTPS is mutually authenticated with X.509 certificates. + +## 6.2 SFTP + +### 6.2.1 General Requirements + +O-RAN architectural elements that implement secure file transfer using SFTP shall: + +- Support secure connection and authentication using SSHv2 Authentication Protocol [2] with all O-RAN specific requirements from Clause 4.1 in this document +- Support SFTPV3 as the SFTP Industry Best Practice [65] + +## 6.3 FTPES + +### 6.3.1 General Requirements + +O-RAN architectural elements that implement secure file transfer using FTPES shall: + +- Support secure connection and authentication using TLS with all O-RAN specific requirements from Clause 4.2 in this document +- Support FTPES as defined in [66] + +## 6.4 HTTPS + +### 6.4.1 General Requirements + +O-RAN architectural elements that implement secure file transfer using HTTPS shall: + +- Support secure connection and authentication using TLS with all O-RAN specific requirements from Clause 4.2 in this document. +- Support HTTPS as defined in [69]. + +# Annex A (normative): OpenAPI specifications + +## A.1 OAuth2.0 API + +### A.1.1 Introduction + +The Open API for the OAuth2.0 Access Token API specified in clause A.1.2 is based on the API definitions in clause 4.7.3.4. + +### A.1.2 OAuth 2.0 Access Token API + +``` +openapi: 3.0.3 +info: + title: OAuth 2.0 Access Token API + version: 1.0.0 + description: | + API for OAuth 2.0. + © 2024, O-RAN ALLIANCE. + All rights reserved. +externalDocs: + description: O-RAN.WG11.SecProtSpecs-R003-v10.00 + url: https://www.o-ran.org/specifications +servers: + - url: '{apiRoot}/oauth2/v1' + variables: + apiRoot: + description: apiRoot as defined in in clause 4.4.1 of 3GPP TS 29.501 + default: https://example.com +paths: + /token: + post: + description: Token endpoint + operationId: AccessTokenRequest + tags: + - Access Token Request + requestBody: + required: true + content: + application/x-www-form-urlencoded: + schema: + $ref: '#/components/schemas/AccessTokenReq' + responses: + '200': + description: Success case 200 OK + content: + application/json: + schema: + $ref: '#/components/schemas/AccessTokenResp' + headers: + Cache-Control: + $ref: '#/components/headers/cache-control' + Pragma: + $ref: '#/components/headers/pragma' + '400': + description: Error in the Access Token Request + content: + application/json: + schema: + $ref: '#/components/schemas/AccessTokenErr' +``` + +#### components: + +#### schemas: + +#### AccessTokenReq: + +``` + +description: Contains information related to the access token request +type: object +properties: + grant_type: + description: Represents the Client Credentials grant type + enum: [ client_credentials ] + type: string + client_id: + description: >- + Represents the identity assigned to the client configured in the + authorization server + type: string + client_secret: + description: >- + Represents the secret assigned to the client configured in the + authorization server + type: string + scope: + description: Represents the scope of the access request + type: string +required: + - grant_type + +``` + +#### AccessTokenRsp: + +``` + +description: Contains information related to the access token response +type: object +properties: + access_token: + description: Represents the access token issued by the authorization server + type: string + token_type: + $ref: '#/components/schemas/token_type' + expires_in: + description: Represents the lifetime in seconds of the access token + type: integer + scope: + description: Represents the scope of the access request + type: string +required: + - access_token + - token_type + +``` + +#### token\_type: + +``` + +description: As described in clause 6.1.1 of IETF RFC 6750 +type: string +enum: + - Bearer + +``` + +#### AccessTokenErr: + +``` + +description: Error returned in the access token response message +type: object +properties: + error: + type: string + enum: + - unauthorized_client + - unsupported_grant_type + - invalid_request + - invalid_scope + - invalid_client + - invalid_grant + error_description: + type: string + error_uri: + type: string +required: + - error + +``` + +``` +headers: + cache-control: + required: true + schema: + type: string + enum: + - no-store + pragma: + required: true + schema: + type: string + enum: + - no-cache +``` + +# Annex (informative): Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.11.27 | 11.00 | More editorial fixes
    Published as Final version 11.00 | +| 2024.11.27 | 10.04 | Disabled automatic update of styles in the document developer settings | +| 2024.11.27 | 10.03 | Further editorial changes | +| 2024.11.27 | 10.02 | Several minor editorial- and format corrections | +| 2024.11.27 | 10.01 | Added DTAG-0013, ATT.AO-0061, ACN.AO-0004 and ERI-0172 | +| 2024.07 | 10.00 | Published as Final version 10.00 | +| 2024.03 | 09.00 | Certificate Profile for O-RAN TLS entity
    Reference Update
    Published as Final version 09.00 | +| 2023.11 | 08.00 | Secure file transfer protocols added
    SSH Update on no root remote login
    ssh-ed448 changed to optional
    Reference on SSH added
    Published as Final version 08.00 | +| 2023.07 | 07.00 | Editorial alignments
    TLS entity certificate profile
    CMPv2 profile update
    Introduction of one-way TLS authentication for OAuth2.0
    Published as Final version 07.00 | +| 2023.03 | 06.00 | Cryptographic operations update
    Published as Final version 06.00 | +| 2022.11 | 05.00 | TLS Cipher update
    Published as Final version 05.00 | +| 2022.07.20 | 04.00 | Addition of CMPv2
    Update of O-Cloud Image protocols
    Addition of mTLS
    Update of OAuth 2.0
    Published as Final version 04.00 | +| 2021.11.08 | 03.00 | Update the O-RAN security protocols and specifications to include mandatory support for TLS 1.3
    Published as Final version 03.00 | +| 2021.07.05 | 02.00 | Addition of DTLS and IPsec requirements.
    Alignment of TLS 1.2 and TLS 1.3 profiles with 3GPP TS 33.210.
    Typographical changes.
    Published as Final version 02.00 | +| 2021.04.01 | 01.00 | Initial version of the document with requirements for TLS and SSH.
    Published as Final version 01.00 | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/16f9489ec205fb5077d6f2c57518cadd_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/16f9489ec205fb5077d6f2c57518cadd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..13fbb5c81237893e4b67a49d0945155b6d5ec329 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/16f9489ec205fb5077d6f2c57518cadd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7c5bf72984ba2b5fb80f0098dfa72e2b18a80ddba64fc2b1a68dcd5ea336f573 +size 67824 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/17398cfc35dde22fa5a80caabe669739_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/17398cfc35dde22fa5a80caabe669739_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ae115f85c71c7c4dd5ac246f8d02e9dc29c8af6 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/17398cfc35dde22fa5a80caabe669739_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c5775240b9ed1a2100a9c61aca08d03763ec191986acc2c52895232c0e85e48b +size 4429 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/1e6530e227e517d332e446ce96d41c7a_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/1e6530e227e517d332e446ce96d41c7a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..608d4637c88d01b5ef26c2ea6fac5163451181e5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/1e6530e227e517d332e446ce96d41c7a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09a9a690ac82dfafaf819eb71a7a8c4e4263caa45ebb82a8f55b5d84f9b85404 +size 138631 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/1f46afdddbf1c41f2431ded35ad03fce_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/1f46afdddbf1c41f2431ded35ad03fce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a2b40c45f2485cf02cbccbfc6ac2396312288680 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/1f46afdddbf1c41f2431ded35ad03fce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f3ec08d77466780329645219f2e274c419d7ccb8c6ac21d92b3150060f73c60f +size 71545 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/31f3e610f71626ee4cd9f1b71b17befd_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/31f3e610f71626ee4cd9f1b71b17befd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..da13db0f461104377b86834d0baa331d693ec7cf --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/31f3e610f71626ee4cd9f1b71b17befd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5346a38de077737d970f5c41af826ae71af0705ff20affbfb7a44fd2483d6182 +size 35813 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/33cdf7bd6dd37c418d42691b08bc9034_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/33cdf7bd6dd37c418d42691b08bc9034_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f97bcd7441c9abc71f2cefd106f72b60361a79e5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/33cdf7bd6dd37c418d42691b08bc9034_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:500b99a88524e832f2abf71a16652b981e1fd4145a241756e200f4b10c15bee7 +size 84615 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/551e35d264492786d0d610557ccc1b55_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/551e35d264492786d0d610557ccc1b55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eca96f14eff173ab5ead5b4ef80ff5827e92c33d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/551e35d264492786d0d610557ccc1b55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8bb0af2dd788e055159db7a05c0b9285e7d655c861421ac8dc37e4b94c3b343 +size 4454 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/66ff70158ea08d31c04d27e923f27838_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/66ff70158ea08d31c04d27e923f27838_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9f21009ff1d229abe40423b6e54385726d101069 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/66ff70158ea08d31c04d27e923f27838_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:00a5c569305eada40b669f0617dccd9a699cc8ca4b981fab786ade5e9da0c72f +size 28679 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/9567c532514e97e8ea09dd96ce7edd53_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/9567c532514e97e8ea09dd96ce7edd53_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a3b6e85bfc66e7c0dfd36db4eac8a6d4ee0e0aa3 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/9567c532514e97e8ea09dd96ce7edd53_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:76660663cf658e8b5aae15083beb700eed23e9156a63a7d1e96384dae4e7d33b +size 4563 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/9628e333dc4d6f610dfb482a49d1c40c_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/9628e333dc4d6f610dfb482a49d1c40c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bfaacd0f715adc13ae1552379f2a9194a6c1a266 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/9628e333dc4d6f610dfb482a49d1c40c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c6df5fe8ca1a8b5cdb83d28bc2c7c7849429838a330636cb3fea49031cf21cad +size 26004 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/aa45edd6acefdfe68b856f88a6ad6458_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/aa45edd6acefdfe68b856f88a6ad6458_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..589c8f7b8923f33ab9234331e6f3642873ccda9d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/aa45edd6acefdfe68b856f88a6ad6458_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:678aac5e51dbd1d9f29c4dffb0cad003a99f4f32bbe037326cc4a7daae27458e +size 76489 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/bdc2cf9e49f32dbe0f80aebff483b7d3_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/bdc2cf9e49f32dbe0f80aebff483b7d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d5662d276e30a768736afe380090a3d3f3b7c26c --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/bdc2cf9e49f32dbe0f80aebff483b7d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bcc7cf212956a24082243f8d61262ef92de140bc91d02a89864de3ce9fccbb15 +size 17733 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/c77fed0c974138fa6fe2ca7b55705430_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/c77fed0c974138fa6fe2ca7b55705430_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ea398970622ef5b6ae49b8ac4499d618addc7927 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/c77fed0c974138fa6fe2ca7b55705430_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a39353f08f36bc1cdfec80a7726319d031b77810e2223cbb7a7eb28b31912bc5 +size 4479 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/c8c280fb70ee49fec80a2a92fb3cc3fa_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/c8c280fb70ee49fec80a2a92fb3cc3fa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..211b3e3c41561cecff2ae09d96a95a84628eec4d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/c8c280fb70ee49fec80a2a92fb3cc3fa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4bc86e5c6afb3e8822db8737a4f9651627f6881da187c576f75bbb1c6fd828a8 +size 4492 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/da8714665d3ead47d648df21434f6d0c_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/da8714665d3ead47d648df21434f6d0c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9a7d2cd25e6b2407cffb4eafb39489b42e6bcd24 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/da8714665d3ead47d648df21434f6d0c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3e1adf52b6eed7ecd6d8437499e0acc6fad996a94f3ee774cdf56324effc66e6 +size 4594 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2d377a7b1ecc3d90d66455a89af93a9d69c05c2 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f53afab4ac078add52c3f0b2a3b8709940df75f38907b6df0bd3e7c4b98620ac +size 4528 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/e5ad9041ce751c5966017093c1de73f0_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/e5ad9041ce751c5966017093c1de73f0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..34df5b0087a7d1d603cae250a968ed89e28dc5ce --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/e5ad9041ce751c5966017093c1de73f0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:03d35ea43677efa0463ba6495f06de6db1dfd3e1368f6072cc7c99458de669dd +size 208254 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/f12017b121db092f9fa1234fbe3e6fcb_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/f12017b121db092f9fa1234fbe3e6fcb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dd134e2f9cb59e6db1d3d235e2dace054909fccb --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/f12017b121db092f9fa1234fbe3e6fcb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d269245c474d5a4f5d1bb2ab39d0fa66f664c9baca0c639df4e15f866e555f7 +size 17820 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/f13e1b396f461742bad83e68d640ce10_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/f13e1b396f461742bad83e68d640ce10_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3f2b48c326581beb1b83a26abfd600f61de251d --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/f13e1b396f461742bad83e68d640ce10_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8b03dbe3aa45941fec265daf37dac0f9dee7bcddc28b8211a141a484e423a9a2 +size 28368 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/raw.md b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..1c180db27bdaea07ce5c312fcb18df7bee734b64 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00/raw.md @@ -0,0 +1,4753 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****Security Requirements and Controls Specifications** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|--------------------------------------------------------------|----| +| Contents..... | 2 | +| Foreword ..... | 4 | +| Modal verbs terminology ..... | 4 | +| 1 Scope..... | 4 | +| 2 References..... | 4 | +| 2.1 Normative references ..... | 5 | +| 2.2 Informative references..... | 7 | +| 3 Definition of terms, symbols and abbreviations ..... | 8 | +| 3.1 Terms..... | 8 | +| 3.2 Abbreviations ..... | 12 | +| 4 Objectives and scope..... | 14 | +| 4.1 Objectives..... | 14 | +| 4.2 Perimeter ..... | 14 | +| 4.2.1 Void ..... | 15 | +| 4.2.2 Void ..... | 15 | +| 4.2.3 Void ..... | 15 | +| 5 Security Requirements and Controls..... | 15 | +| 5.0 Introduction ..... | 15 | +| 5.1 O-RAN Architecture Elements ..... | 16 | +| 5.1.1 Service Management and Orchestration (SMO) ..... | 16 | +| 5.1.2 Non-RT RIC and rApps..... | 19 | +| 5.1.3 Near-RT RIC and xApps..... | 20 | +| 5.1.4 O-CU-CP/UP ..... | 26 | +| 5.1.5 O-DU ..... | 26 | +| 5.1.6 O-RU ..... | 26 | +| 5.1.7 O-eNB..... | 26 | +| 5.1.8 O-Cloud ..... | 27 | +| 5.1.9 Shared O-RU ..... | 37 | +| 5.2 Interfaces maintained by O-RAN..... | 38 | +| 5.2.1 A1 Interface ..... | 38 | +| 5.2.2 O1 Interface ..... | 39 | +| 5.2.3 O2 Interface ..... | 41 | +| 5.2.4 E2 Interface ..... | 42 | +| 5.2.5 Open Fronthaul Interface..... | 42 | +| 5.2.6 R1 Interface ..... | 53 | +| 5.2.7 Y1 Interface ..... | 54 | +| 5.3 Transversal requirements ..... | 55 | +| 5.3.1 Software Bill of Materials ..... | 55 | +| 5.3.2 Common Application Lifecycle Management ..... | 55 | +| 5.3.3 Network Protocols and Services..... | 58 | +| 5.3.4 Robustness of Common Transport Protocols ..... | 59 | +| 5.3.5 Robustness against Volumetric DDoS Attack..... | 59 | +| 5.3.6 Robustness of O-RAN architecture element software..... | 59 | +| 5.3.7 Password-Based Authentication..... | 60 | +| 5.3.8 Security Log Management ..... | 60 | +| 5.3.9 Certificate Management Framework..... | 70 | +| 5.3.10 Application Programming Interfaces (APIs)..... | 72 | +| 5.3.11 Trust Anchor Provisioning ..... | 73 | +| 5.3.12 AI/ML Security ..... | 74 | + +| | | | +|-------|----------------------------------------------------------------------------------------------|-----| +| 6 | SBOM Guidelines for O-RAN..... | 75 | +| 6.1 | SBOM Overview..... | 75 | +| 6.2 | 75 | | +| 6.3 | SBOM Requirements for O-RAN..... | 76 | +| 6.3.1 | Requirements..... | 76 | +| 6.3.2 | Security Controls ..... | 76 | +| | Annex A (informative): Security Principles mapping to Security Requirements ..... | 76 | +| | Annex B (informative): Security: List of 3GPP security requirements ..... | 78 | +| | Annex C (informative): Guidance on Security Requirements & Controls ..... | 96 | +| | Annex D (informative): Mapping of Threats to Requirements and Requirements to Controls ..... | 103 | +| | Annex E (informative): Summary of O-RAN Security Controls..... | 135 | +| | Annex F (informative): Change history ..... | 137 | +| | History ..... | 141 | + +## List of Tables + +| | | +|------------------------------------------------------------------------------------------|-----| +| Table 5-1: Summary of the Security Controls for Near-RT RIC APIs..... | 24 | +| Table 5.2.2.3-1: Default values of the NACM Global Enforcement..... | 43 | +| Table 5.3.8.11.1-1: Types of Security Events by O-RAN Component ..... | 69 | +| Table A-1: Security Principles mapping to Security Requirements defined in [i.14]. ..... | 81 | +| Table B-1: References for 3GPP Security requirements ..... | 83 | +| Table B-2: 3GPP Security requirements..... | 83 | +| Table C.3.1-1: Certificate enrolment for NF Deployment ..... | 105 | +| Table D-1: Mapping of Threats defined in [i.14] to Security Requirements ..... | 108 | +| Table D-2: Map between Security Requirements and Security Controls..... | 120 | +| Table E-1. Summary of O-RAN Security Controls..... | 140 | + +## List of Figures + +| | | +|---------------------------------------------------------------------------------------------------------------------|-----| +| Figure 4-1: Logical Architecture of O-RAN system [2] ..... | 16 | +| Figure 5.1.1.2.2-1: mTLS or TLS for SMO Internal Communications ..... | 19 | +| Figure 5.1.1.2.3-1: mTLS on SMO External interfaces ..... | 20 | +| Figure 5.1.2.1-1: SMO/Non-RT RIC Framework supporting Kafka based protocol using TLS ..... | 21 | +| Figure 5.1.3.2-1: Security procedure for xApp registration..... | 26 | +| Figure 5.2.1.2-1: mTLS on A1 interface ..... | 41 | +| Figure 5.2.5.5.3.2-1: Normal Operation of 802.1X Port Based Authentication in the O-RAN Fronthaul architecture .... | 53 | +| Figure 5.2.5.6.2-1: End-to-End MACsec solution for fronthaul security protection ..... | 54 | +| Figure 5.2.6.2-1: mTLS on R1 interface ..... | 57 | +| Figure 5.3.12.2-1: EXAMPLE of a deep neural network AI/ML model split across five inference ..... | 79 | +| Figure C.1.2-1: Example of Remote AS ..... | 103 | +| Figure C.3.1-2: Certificate enrolment for NF Deployment..... | 107 | + +# --- Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the Security Requirements and appropriate Security Controls per O-RAN interface and per O-RAN component. + +The following interfaces are not covered by this document: + +- E1 +- F1-c +- F1-u +- NG-c +- NG-u +- X2-c +- X2-u +- Xn-c +- Xn-u +- Uu + +# --- 2 References + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18, or the latest 3GPP release prior to Release 18 that includes that document. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +## 2.1 Normative references + +The following referenced documents are necessary for the application of the present document. + +- [1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications" +- [2] O-RAN ALLIANCE TS: "O-RAN Architecture Description" +- [3] O-RAN ALLIANCE TS: "O-RAN Security Protocols Specifications" +- [4] Void +- [5] O-RAN ALLIANCE TS: "O-RAN A1 interface: Transport Protocol" +- [6] O-RAN ALLIANCE TS: "O-RAN O2 General Aspects and Principles" +- [7] O-RAN ALLIANCE TS: "O-RAN Near-Real-time RAN Intelligent Controller Architecture & E2 General Aspects and Principles" +- [8] O-RAN ALLIANCE TS: "Cloud Platform Reference Designs" +- [9] IETF RFC 6241: "Network Configuration Protocol (NETCONF)" +- [10] IETF RFC 8341: "Network Configuration Access Control Model" +- [11] IETF RFC 4513: "Lightweight Directory Access Protocol (LDAP): Authentication Methods and Security Mechanisms" +- [12] IEEE Std 802.1X-2020: "IEEE Standard for Local and Metropolitan Area Networks--Port-Based Network Access Control" (Revision of IEEE Std 802.1X-2010 Incorporating IEEE Std 802.1Xbx-2014 and IEEE Std 802.1Xck-2018), vol., no., pp.1-289, 28 Feb. 2020, doi: 10.1109/IEEESTD.2020.9018454 +- [13] O-RAN ALLIANCE TS: "O-RAN Control, User and Synchronization Plane Specification" +- [14] O-RAN ALLIANCE TS: "O-RAN Management Plane Specification" +- [15] O-RAN ALLIANCE TS: "O-RAN Deployment Scenarios and Base Station Classes" +- [16] O-RAN ALLIANCE TS: "O-RAN Operation and Maintenance Architecture" +- [17] "The Minimum Elements for a Software Bill of Materials (SBOM), Pursuant to Executive Order 14028 on Improving the Nation's Cybersecurity", U.S. DoC and NTIA, July 2021" +- [18] SPDX, +- [19] CycloneDX, +- [20] NISTIR 8060: "Guidelines for the Creation of Interoperable Software Identification (SWID) Tags, David Waltermire et al., U.S. NIST, 2016, +- [21] ISO/IEC 5962:2021 - "Information technology — SPDX® Specification", V2.2.1, August 2021 +- [22] IETF RFC 2865: "Remote Authentication Dial In User Service (RADIUS)" +- [23] IETF RFC 2866: "RADIUS accounting" +- [24] IETF RFC 2869: "RADIUS Extensions" +- [25] IETF RFC 4072: "Diameter Extensible Authentication Protocol (EAP) Application" +- [26] O-RAN ALLIANCE TS: "Xhaul Packet Switched Architectures and Solutions" +- [27] IEEE 1588-2019: "IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems" +- [28] IETF RFC 7384: "Security Requirements of Time Protocols in Packet Switched Networks" + +- [29] 3GPP TS 33.511: "Security Assurance Specification (SCAS) for the next generation Node B (gNodeB) network product class" +- [30] O-RAN ALLIANCE TS: "Synchronization Architecture and Solution Specification" +- [31] O-RAN ALLIANCE TS: "O-RAN Control, User, and Synchronization Plane Specification" +- [32] 3GPP TS 38.323: "NR; Packet Data Convergence Protocol (PDCP)" +- [33] O-RAN ALLIANCE TS: "Near-RT RIC Architecture" +- [34] IETF RFC 6749: "The OAuth 2.0 Authorization Framework" +- [35] IETF RFC 7519: "JSON Web Token (JWT)" +- [36] IETF RFC 7515: "JSON Web Signature (JWS)" +- [37] O-RAN ALLIANCE TS: "Non-RT RIC: Architecture" +- [38] O-RAN ALLIANCE TS: "A1 interface General Aspects & Principles Specification" +- [39] O-RAN ALLIANCE TS: "R1 interface: General Aspects and Principles" +- [40] O-RAN ALLIANCE TS: "Non-RT RIC & A1 Interface: Use Cases and Requirements" +- [41] ETSI GS NFV-SEC 021: "VNF Package Security Specification" +- [42] ETSI GS NFV-SOL 004: "Protocols and Data Models; VNF Package specification" +- [43] ETSI GS NFV-IFA 011: "Management and Orchestration; VNF Descriptor and Packaging Specification" +- [44] Void +- [45] Void +- [46] "Security Guidance for 5G Cloud Infrastructures, Part I: Prevent and Detect Lateral Movement", page 5, US NSA ESF and US DHS CISA, October 2021, [https://media.defense.gov/2021/Oct/28/2002881720/-1/-1/0/SECURITY\\_GUIDANCE\\_FOR\\_5G\\_CLOUD\\_INFRASTRUCTURES\\_PART\\_I\\_20211028.PDF](https://media.defense.gov/2021/Oct/28/2002881720/-1/-1/0/SECURITY_GUIDANCE_FOR_5G_CLOUD_INFRASTRUCTURES_PART_I_20211028.PDF) +- [47] ETSI GS NFV-SEC 021: "NF Package Security Specification", V2.6.1 (2019-06), clause 6.4, [https://www.etsi.org/deliver/etsi\\_gs/NFV-SEC/001\\_099/021/02.06.01\\_60/gs\\_nfv-sec021v020601p.pdf](https://www.etsi.org/deliver/etsi_gs/NFV-SEC/001_099/021/02.06.01_60/gs_nfv-sec021v020601p.pdf) +- [48] ETSI GS NFV-SOL 004: "VNF Package and PNFD Archive specification" V4.3.1 (2022-07), clause 5.5, [https://www.etsi.org/deliver/etsi\\_gs/NFV-SOL/001\\_099/004/04.03.01\\_60/gs\\_NFV-SOL004v040301p.pdf](https://www.etsi.org/deliver/etsi_gs/NFV-SOL/001_099/004/04.03.01_60/gs_NFV-SOL004v040301p.pdf) +- [49] ETSI GR NFV-SEC 018: "Report on NFV Remote Attestation Architecture" [https://www.etsi.org/deliver/etsi\\_gr/NFV-SEC/001\\_099/018/01.01.01\\_60/gr\\_NFV-SEC018v010101p.pdf](https://www.etsi.org/deliver/etsi_gr/NFV-SEC/001_099/018/01.01.01_60/gr_NFV-SEC018v010101p.pdf) +- [50] DoD 5220.22: "M data sanitization method" +- [51] Kubernetes Documentation - Encrypting Secret Data at Rest, +- [52] Federal Information Processing Standards Publication (FIPS PUB) 140-3: "Security Requirements for Cryptographic Modules", + +- [53] TPM 2.0 Library +- [54] ETSI GR NFV-SEC 003 Network Functions Virtualisation (NFV): "NFV Security; Security and Trust Guidance", [https://www.etsi.org/deliver/etsi\\_gr/NFV-SEC/001\\_099/003/01.02.01\\_60/gr\\_nfv-sec003v010201p.pdf](https://www.etsi.org/deliver/etsi_gr/NFV-SEC/001_099/003/01.02.01_60/gr_nfv-sec003v010201p.pdf) +- [55] 3GPP TS 33.501: "Security architecture and procedures for 5G System" +- [56] 3GPP TS 33.401: "3GPP System Architecture Evolution (SAE); Security architecture" +- [57] ISO/IEC 27000:2018: "Information technology - Security techniques - Information security management systems - Overview and vocabulary" + +- [58] NIST SP 800-92: "Guide to Computer Security Log Management" + +- [59] IETF RFC 4210: "Internet X.509 Public Key Infrastructure Certificate Management Protocol (CMP)". +- [60] IETF RFC 5905: "Network Time Protocol Version 4: Protocol and Algorithms Specification" +- [61] IETF RFC 3339, "Date and Time on the Internet: Timestamps" +- [62] ISO 8601: "Date-time formats" +- [63] IETF RFC 8915: "Network Time Security for the Network Time Protocol" +- [64] IETF RFC 5424: "The Syslog Protocol" +- [65] IETF RFC 5425: "Transport Layer Security (TLS) Transport Mapping for Syslog" +- [66] O-RAN ALLIANCE TS: "Y1 interface: General Aspects and Principles" +- [67] NIST SP800-162: "Guide to ABAC Definition and Considerations", +- [68] NIST SP800-122: "Guide to Protecting the Confidentiality of Personally Identifiable Information (PII)", . +- [69] IETF RFC 8366: "A Voucher Artifact for Bootstrapping Protocols" +- [70] IETF RFC 8995: "Bootstrapping Remote Secure Key Infrastructure (BRSKI)" +- [71] IETF RFC 8572: "Secure Zero Touch Provisioning (SZTP)" +- [72] 3GPP TS 28.314: "Management and orchestration; Plug and connect; Concepts and requirements" +- [73] 3GPP TS 28.315: "Management and orchestration; Plug and connect; Procedure flows" +- [74] 3GPP TS 28.316: "Management and orchestration; Plug and connect; Data formats" +- [75] NIST SP 800-88: "Guidelines for Media Sanitization", +- [76] 3GPP TS 33.117: "Catalogue of general security assurance requirements" +- [77] IETF RFC 4122: "A Universally Unique IDentifier (UUID) URN Namespace" +- [78] IETF RFC 4493: "The AES-CMAC Algorithm" +- [79] IEEE Std 802.1AE-2018: "IEEE Standard for Local and metropolitan area networks —Media Access Control (MAC) Security" +- [80] O-RAN ALLIANCE TS: "O-RAN O2dms Interface Specification: Profile based on ETSI NFV Protocol and Data Models" +- [81] IETF RFC 5280: "Internet X.509 Public Key Infrastructure Certificate and Certificate Revocation List (CRL) Profile" +- [82] O-RAN ALLIANCE TS: "Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN" +- [83] Secure by Design: Product Security Bad Practices, US DHS CISA, October 16, 2024, + + +## 2.2 Informative references + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] NIST SP 800-190: "APPLICATION CONTAINER SECURITY GUIDE", + + +- [i.2] ENISA: "NFV SECURITY IN 5G Challenges and Best Practices", + +- [i.3] IBM: "Securing the container platform, Build a chain of trust", + +- [i.4] Void +- [i.5] Thales: "Kubernetes Secrets Encryption - Integration Guide", + +- [i.6] IBM: "Encrypting Kubernetes secrets with Key Management Service plug-in", + +- [i.7] NIST IR 8320: "HARDWARE-ENABLED SECURITY: ENABLING A LAYERED APPROACH TO PLATFORM SECURITY", . +- [i.8] "Recent trends in applying TPM to cloud computing", + +- [i.9] API Security Project, Open Worldwide Application Security Project (OWASP), [OWASP API Security Project | OWASP Foundation](https://owasp.org/OWASP_API_Security_Project/). +- [i.10] Kafka Documentation, +- [i.11] Void +- [i.12] NIST IR 4734: "Foundations of a Security Policy for Use of the National Research and Educational Network", +- [i.13] O-RAN ALLIANCE TR: "Study on Security for Fronthaul CUS-Plane" +- [i.14] O-RAN ALLIANCE TR: "O-RAN Security Threat Modeling and Risk Assessment" +- [i.15] 3GPP TR 33.848: "Study on Security Impacts of Virtualisation" +- [i.16] ETSI EG 203 647: "Methods for Testing and Specification (MTS); Methodology for RESTful APIs specifications and testing" +- [i.17] ETSI TR 28.908 v18.1.0 5G; Study on Artificial Intelligence/Machine Learning (AI/ML) management (3GPP TR 28.908 version 18.1.0 Release 18) +- [i.18] AI security concerns in a nutshell- Practical AI-Security guide, 2023, Federal Office for Information Security, [https://www.bsi.bund.de/SharedDocs/Downloads/EN/BSI/KI/Practical\\_AI-Security\\_Guide\\_2023.pdf](https://www.bsi.bund.de/SharedDocs/Downloads/EN/BSI/KI/Practical_AI-Security_Guide_2023.pdf) +- [i.19] +- [i.20] NIST AI 100-2e2023 Adversarial Machine Learning: A Taxonomy and Terminology of Attacks and Mitigations, draft white paper, US DoC NIST January 2024 +- [i.21] Kubernetes documentation - Admission Controllers Reference, +- [i.22] RedHat OpenShift documentation - Managing security Policies, + + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For definitions of the security terms Attack, Risk, Security control, Technical control, Threat, and Vulnerability used in this document, refer to [i.14]. + +For the purposes of the present document, the following terms apply: + +**A1:** Interface between Non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**A1 policy:** Type of declarative policies expressed using formal statements that enable the Non-RT RIC function in the SMO to guide the Near-RT RIC function, and hence the RAN, towards better fulfilment of the RAN intent. + +**A1 Enrichment information (EI):** Information utilized by Near-RT RIC that is collected or derived at SMO/Non-RT RIC either from non-network data sources or from network functions themselves. + +**Account and Identity Events:** Events generated by user identification and access control. + +**Adversarial training:** A general method that augments the training data with adversarial examples generated iteratively during training using their correct labels. The stronger the adversarial attacks for generating adversarial examples are, the more resilient the trained model becomes [i.20]. + +**AI/ML model:** An algorithm that applies AI/ML techniques to produce model output data based on model input data. (see [37] clause 3.1). + +**Application descriptor:** A template that defines the characteristics and requirements of the Application, allowing it to be deployed, managed, and orchestrated within the O-Cloud. It typically includes information such as the Application's functional behaviour, deployment requirements, resource needs (such as CPU, memory, and storage), connectivity requirements, performance metrics, scalability options, and any dependencies or prerequisites. It also contains information related to security, including the service availability requirements and access rules for controlling the traffic direction to the Application. + +**Application Events:** Events generated by O-RAN Network Functions. + +**Application package:** Software package of xApps, rApps, and VNFs/CNFs (i.e., O-CU, O-DU, and Near-RT RIC). + +**Audit Records:** "Audit records contain security event information such as successful and failed authentication attempts, file accesses, security policy changes, account changes (e.g., account creation and deletion, account privilege assignment), and use of privileges. OSs typically permit system administrators to specify which types of events should be audited and whether successful and/or failed attempts to perform certain actions should be logged." Defined in NIST SP 800-92 [58], clause 2.1.2. + +**black-side:** Identifies the Ethernet Data Encryption device (EDE) port that uses MACsec to protect transmitted frames and verify received frames. + +**Common Port:** An instance of the MAC Internal Sublayer Service (ISS) used by the MAC Security Entity (SecY) to provide transmission and reception of frames for both the controlled and uncontrolled ports. + +**Controlled Port:** The access point used to provide the secure MAC Service to a client of a MAC Security Entity (SecY). + +**Data Access Event:** Events generated by any O-RAN component accessing, retrieving, modifying, or deleting data in files or databases. + +**Data Sanitization:** Removing all the sensitive parts of the data before using it for training makes it impossible for intruders to extract the data from the trained model [i.18]. + +**E2:** Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. + +**E2 Node:** a logical node terminating E2 interface. In this version of the specification, O-RAN nodes terminating E2 interface are: + +- for NR access: O-CU-CP, O-CU-UP, O-DU or any combination. +- for E-UTRA access: O-eNB. + +**End-to-End MACsec:** MACsec is enabled at the Open Fronthaul endpoints, providing encryption for remote endpoints, while intermediary switches and TNE remain MACsec-unaware. + +**Entity:** An individual (person), device, or process that interacts with an ORAN component. + +**Ethernet Data Encryption device (EDE):** A two-port bridge that transmits and receives frames that are assumed to be unprotected to and from one red-side port, and conditionally relays those frames to and from its other black-side port, protecting and verifying frames transmitted and received on the black-side port using MACsec. + +**External Interface:** The interface between the SMO and an External System. + +**External System:** A data source outside the O-RAN domain that provides enrichment data to the SMO. + +**FCAPS:** Fault, Configuration, Accounting, Performance, Security. + +**Feature:** In the AI/ML context, a feature is a measurable property of some data sample that is used as input for an ML model for training and inference. A feature should have predictive power for the model it is being used in.[i.19] + +**Feature Scaling:** Feature scaling in AI/ML is a data preprocessing technique (i.e., using suitable mathematical transformations) used to standardize the range of independent features present in a dataset. By suitable Feature Scaling, the impact of variations in the data on the Model's output is reduced. + +**General Security Event:** Events generated by the enabling, disabling or configuration of security features in O-RAN components. + +**Hop-by-Hop MACsec:** MACsec is enabled at the Open Fronthaul endpoints and TNEs providing point-to-point encryption at every hop in the Open Fronthaul network. + +**Information Security Event:** "Identified occurrence of a system, service or network state indicating a possible breach of information security policy or failure of controls, or a previously unknown situation that can be security relevant." Defined in ISO/IEC 27000:2018 [57], clause 3.30. + +**Information Security Incident:** "Single or a series of unwanted or unexpected information security events that have a significant probability of compromising business operations and threatening information security." Defined in ISO/IEC 27000:2018 [57], clause 3.31. + +**Intents:** A declarative policy to steer or guide the behaviour of RAN functions, allowing the RAN function to calculate the optimal result to achieve stated objective. + +**Isolation:** A security strategy that separates individual applications or software components from one another, ensuring that they run independently and do not interfere with each other's operations. + +**Log:** "A log is a record of the events occurring within an organization's systems and networks. Logs are composed of log entries; each entry contains information related to a specific event that has occurred within a system or network." Defined in NIST SP 800-92 [58], clause 2. + +**Log streaming:** In information technology, log streaming refers to the near real-time transmission and analysis of log data generated by various software applications, systems, or devices. + +**MAC Security Entity (SecY):** The entity that operates the MAC Security protocol within a system. + +**Management and Orchestration Event:** Events generated by SMO operations. + +**Model splitting:** Model splitting includes the ability to distribute different parts of an AI/ML model across multiple nodes or domains, ensuring that no single node has access to the complete model. This approach can help mitigate the risk of model theft, data leakage, and unauthorized access. + +**Near-RT RIC:** O-RAN near-real-time RAN Intelligent Controller: a logical function that enables real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. + +**Network Events:** Events generated by network activity from operating systems, hypervisors, or container engines. + +**Non-RT RIC:** O-RAN non-real-time RAN Intelligent Controller: a logical function that enables non-real-time control and optimization of RAN elements and resources, AI/ML workflow including model training and updates, and policy-based guidance of applications/features in Near-RT RIC. + +**O-CU:** O-RAN Central Unit: a logical node hosting O-CU-CP and O-CU-UP + +**O-Cloud Compute Pool:** It refers to a cohesive set of computational resources within the O-Cloud infrastructure where multiple nodes work in harmony to provide a unified environment designed to host and manage O-RAN applications and services. In the context of Kubernetes, an O-Cloud Compute Pool is equivalent to a "cluster". + +**O-Cloud data storage:** The Storage resource of the O-Cloud Node (Refer clause 3.4.3.5.5 of [6]) + +**O-Cloud instance ID:** The O-Cloud instance ID is a unique identifier assigned to components within the O-Cloud platform, including VMs, pods, containers, nodes, and compute pools (E.g., a cluster in Kubernetes). This ensures uniqueness across the entire O-Cloud environment, irrespective of the component type. For instance, a VM, a pod, a container, a node, and a cluster will each have a distinct O-Cloud instance ID within the platform, ensuring that there is no ambiguity in identification. + +**O-Cloud nodes:** An O-Cloud node refers to a computational unit or entity within the O-Cloud infrastructure. It serves as a host for running O-RAN applications. Each O-Cloud node contributes computational resources, storage, and networking capabilities to the overall O-Cloud system, ensuring scalability, redundancy, and efficient workload distribution. + +**O-Cloud platform software component:** A software module within the O-Cloud platform that provides essential functionalities and services to enable the deployment, management, and utilization of O-Cloud resources by O-RAN Network Functions. Some examples of O-Cloud platform software component include virtual machine managers, container orchestration frameworks (e.g., Kubernetes control plane) and database services. + +**O-Cloud secure environment:** The O-Cloud secure environment is a logically defined and controlled boundary within the O-Cloud platform, designed to protect all sensitive information and operations. It leverages a combination of hardware-based and software-based security measures to defend against unauthorized access, tampering, and data leakage. + +**O-CU-CP:** O-RAN Central Unit – Control Plane: a logical node hosting the RRC and the control plane part of the PDCP protocol. + +**O-CU-UP:** O-RAN Central Unit – User Plane: a logical node hosting the user plane part of the PDCP protocol and the SDAP protocol. + +**O-DU:** O-RAN Distributed Unit: a logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. + +**O-RU:** O-RAN Radio Unit: a logical node hosting Low-PHY layer and RF processing based on a lower layer functional split. + +**O-RAN vendor:** Provider of any component of O-RAN + +**O1:** Interface between management entities (NMS/EMS/MANO) and O-RAN managed elements, for operation and management. + +**O2:** Interface between SMO and the O-Cloud to provide cloud resources management and workload management for supporting O-RAN cloudified network functions. + +**R1:** Interface between rApps and Non-RT RIC Framework via which R1 Services can be produced and consumed. + +**R1 Services:** A collection of services including, but not limited to, service registration and discovery services, authentication and authorization services, AI/ML workflow services, and A1, O1 and O2 related services. + +**RAN:** Generally referred to as Radio Access Network. + +**rApps:** Non-RT RIC application: an application designed to consume and/or produce R1 services. + +**rApp instance:** An individual occurrence of an application running in the Non-RT RIC runtime environment. [37] + +**rApp instance identifier:** A unique identifier for each rApp instance, assigned by the SMO/Non-RT RIC framework during rApp registration. [37]. + +**red-side:** Identifies the Ethernet Data Encryption device (EDE) port that does not use MACsec to protect transmitted frames or verify received frames. + +**Relevant Features:** Relevant Features are individual measurable properties or characteristics of a data sample that have a significant impact on the model's ability to make accurate predictions or classifications. These features are directly linked to the target variable or outcome the model is trying to predict. + +**Security Controls:** A solution designed to meet a set of defined security requirements to protect the confidentiality, integrity, and availability of O-RAN elements. + +**Security Log:** A log that contains audit records and security-related system events. + +**Sensitive:** A descriptor of information whose loss, misuse, or unauthorized access or modification could adversely affect security [i.12]. + +**Service Management and Orchestration (SMO):** The O-RAN Service Management and Orchestration system as specified in the O-RAN Architecture Description (OAD) document [2], clause 5.3.1. + +**Shared Data Layer (SDL):** API for accessing shared data storage. + +**Solution Provider:** An application developer who delivers applications to Service Providers. [16]. + +**Service Provider:** A network provider who is planning to deploy applications into their network. [16]. + +**NOTE:** The term is also used to refer to the Telco Operator and/or the O-Cloud Provider since the Application package verification might be performed by both or by one or the other, depending upon the O-Cloud deployment models. The Telco Operator might act as the O-Cloud Provider (in case of private cloud model), or they might be two different entities (in case of hybrid or public cloud models). + +**System Events:** "System events are operational actions performed by OS components, such as shutting down the system or starting a service. Typically, failed events and the most significant successful events are logged, but many OSs permit administrators to specify which types of events will be logged. The details logged for each event also vary widely; each event is usually timestamped, and other supporting information could include event, status, and error codes; service name; and user or system account associated with an event." Defined in NIST SP 800-92 [58], clause 2.1.2. + +**Time of Day (ToD):** Within the O-Cloud, ToD represents the precise hour, minute, and second of a day, serving as a unified time reference across the infrastructure. This consistent time reference is essential to ensure that all nodes hosting O-RAN applications, operate in synchronization. Accurate ToD alignment in the O-Cloud is vital for tasks like event logging, data processing, and transaction sequencing, ensuring operational consistency and reliability across the entire O-Cloud environment. + +**Uncontrolled Port:** The access point used to provide the insecure MAC Service to a client of a MAC Security Entity (SecY). + +**xApp:** An application consuming and/or producing Near-RT RIC services via the Near-RT RIC API to provide value added control of, or guidance to the E2 Nodes. + +**Y1:** An interface between Near-RT RIC and Y1 consumers, as defined in O-RAN Architecture Description [2], clause 5.4.18. The interface enables RAN analytics information exposure from Near-RT RIC. + +## 3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [1]. + +| | | +|-------|---------------------------------------------| +| AI/ML | Artificial Intelligence/Machine Learning | +| BMCA | Best Master Clock Algorithm | +| CNF | Cloud-native Network Function | +| DDoS | Distributed Denial of Service | +| DMS | Deployment management services (of O-Cloud) | +| DTLS | Datagram Transport Layer Security | +| eCPRI | enhanced Common Public Radio Interface | + +| | | +|---------|-------------------------------------------------------------------------------------------------------------------| +| EDE-CC | Ethernet Data Encryption device with red-side recognition of C-TAGs and black-side addition and removal of C-TAGs | +| eNB | e NodeB (applies to LTE) | +| FHM | Fronthaul Multiplexer | +| FOCOM | Federated O-Cloud Orchestration & Management | +| FOSS | Free and Open Source Software | +| FTP | File Transfer Protocol | +| FTPS | File Transfer Protocol Secure | +| gNB | g NodeB (applies to NR) | +| IMS | Infrastructure management services (of O-Cloud) | +| ISS | MAC Internal Sublayer Service | +| IPsec | Internet Protocol Security | +| KPI | Key Performance Indicator | +| LLS | Lower Layer Split | +| MACsec | Media Access Control security | +| MFA | Multi-Factor Authentication | +| mTLS | mutual Transport Layer Security | +| NETCONF | Network Configuration Protocol | +| NF | Network Function | +| NFO | Network Function Orchestration | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| OSC | O-RAN Software Community | +| PDCP | Packet Data Convergence Protocol | +| PKIX | Public-Key Infrastructure using X.509 [81] | +| PNF | Physical Network Function | +| PTP | Precision Timing Protocol | +| RAN | Radio Access Network | +| rAppId | rApp Instance Identifier | +| RBAC | Role-based Access Control | +| RIC | O-RAN RAN Intelligent Controller | +| SBOM | Software Bill of Materials | +| SDL | Shared Data Layer | +| SDLC | Software Development Life Cycle | +| SecY | MAC Security Entity | +| SMO | Service Management and Orchestration | +| SOH | Shared Operator Host | +| SPDX | Software Package Data eXchange | +| SRO | Shared Resource Operator | + +**O-RAN.WG11.SecReqCtlSpecs.0-R004-v11.00** + +![O-RAN Alliance Logo](da8714665d3ead47d648df21434f6d0c_img.jpg) + +| | | +|-------|--------------------------------------------------------------------------| +| SSH | Secure Shell | +| SWID | Software Identification | +| T-BC | Telecom Boundary Clock | +| T-GM | Telecom Grandmaster | +| TNE | Transport Network Equipment (an O-RAN term to denote a transport device) | +| TLS | Transport Layer Security | +| T-TC | Telecom Transparent Clock | +| T-TSC | Telecom Time Synchronous Clock | +| VM | Virtual machine | +| VNF | Virtual Network Function | + +# 4 Objectives and scope + +## 4.1 Objectives + +The present document specifies security requirements and security controls per O-RAN defined interface and O-RAN defined network function. It elaborates on O-RAN Threat Modeling and Risk Assessment [i.14] that identified assets to be protected, analysed the O-RAN components for vulnerabilities, examined potential threats associated with those vulnerabilities and provided security principles which stakeholders should address when building a secure end-to-end O-RAN system. + +## 4.2 Perimeter + +![Figure 4-1: Logical Architecture of O-RAN system [2]](aa45edd6acefdfe68b856f88a6ad6458_img.jpg) + +**Figure 4-1: Logical Architecture of O-RAN system [2]** + +Figure 4-1: Logical Architecture of O-RAN system [2] + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification +14 + +As specified in [2] and illustrated in Figure 4-1, the logical architecture of O-RAN includes the following components, interfaces, and protocols: + +1. O-RAN Architecture components + - Network functions and applications + - Service Management and Orchestration (SMO) + - Non-RT RIC and rApps + - Near-RT RIC and xApps + - O-CU-CP/UP + - O-DU + - O-RU + - O-eNB + - Cloud computing platform + - O-Cloud comprising physical infrastructure nodes to host the relevant O-RAN functions (such as Near-RT RIC, O-CU-CP, O-CU-UP, and O-DU) and, supporting software components (such as Operating System, Virtual Machine Monitor, Container Runtime) and the appropriate management and orchestration functions. +2. Interfaces defined by O-RAN + - A1 Interface between Non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + - O1 Interface connecting the SMO to the Near-RT RIC, one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. + - O2 Interface between the SMO and the O-Cloud + - E2 Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, one or more O-DUs, and one or more O-eNBs. + - Open Fronthaul CUS-Plane Interface between O-RU and O-DU + - Open Fronthaul M-Plane Interface between O-RU and O-DU as well as between O-RU and SMO + +4.2.1 Void + +4.2.2 Void + +4.2.3 Void + +# --- 5 Security Requirements and Controls + +## 5.0 Introduction + +This clause describes the O-RAN security requirements and controls per O-RAN maintained interfaces and network functions. Security requirements and controls specified in this document are built upon Security Principles defined in [i.14] which intent to protect critical assets identified. + +Protection levels of critical assets as defined in [i.14] – Confidentiality, Integrity, Replay, Authentication, Authorisation – are now specified as normative Security Requirements and Controls. + +In Annex D, mappings between threats and requirements, and between requirements and controls, are provided. These mappings illustrate how the specific threats defined in [i.14] are addressed by corresponding security requirements and how these requirements are subsequently implemented through various controls. + +## 5.1 O-RAN Architecture Elements + +### 5.1.1 Service Management and Orchestration (SMO) + +#### 5.1.1.1 Security Requirements + +##### 5.1.1.1.1 SMO + +**REQ-SEC-SMO-1:** SMO shall support authentication of SMO functions. + +**REQ-SEC-SMO-2:** SMO shall support authentication of External Systems. + +**REQ-SEC-SMO-3:** SMO functions shall support authorization as a resource owner/server and client for internal requests. + +**REQ-SEC-SMO-4:** SMO shall support authorization of the service requests received from External Systems. + +**REQ-SEC-SMO-5:** SMO shall be able to recover, without catastrophic failure, from a volumetric DDoS attack across the O2 interface, due to anomalous behaviour or malicious intent. + +**REQ-SEC-SMO-6:** SMO shall be able to recover, without catastrophic failure, from a volumetric DDoS attack across an External Interface, due to anomalous behaviour or malicious intent. + +**REQ-SEC-SMO-7:** Each SMO function shall be able to recover, without catastrophic failure, from a volumetric DDoS attack during SMO Internal Communications, due to anomalous behaviour or malicious intent. + +##### 5.1.1.1.2 SMO Internal Communications + +**REQ-SEC-SMO-Internal-1:** SMO Internal Communications shall support confidentiality, integrity, and replay protection between SMO functions. + +**REQ-SEC-SMO-Internal-2:** SMO Internal Communications shall support mutual authentication between SMO functions. + +##### 5.1.1.1.3 SMO External Interfaces + +External Interfaces not specified by O-RAN that provide services to SMO, acting in a consumer role, shall meet minimum security requirements specified in this clause. + +**REQ-SEC-SMO-External-1:** SMO External Interfaces shall support confidentiality, integrity, and replay protection. + +**REQ-SEC-SMO-External-2:** SMO External Interfaces shall support mutual authentication. + +**REQ-SEC-SMO-External-3:** SMO External Interfaces shall support authorization with the principle of least privilege. + +##### 5.1.1.1.4 SMO Logging + +The below mentioned requirements are referring to securing the event logs in SMO. + +**REQ-SEC-SMO-Log-1:** SMO shall support forwarding of event logs to a mutually authenticated remote location. + +**REQ-SEC-SMO-Log-2:** SMO shall provide confidentiality and integrity protection for event logs transferred to a remote server. + +**REQ-SEC-SMO-Log-3:** SMO may support configuration settings that allow selection of remote servers to securely transfer the event logs. + +**REQ-SEC-SMO-Log-4:** SMO shall be capable of logging the event logs locally on itself. + +**REQ-SEC-SMO-Log-5:** SMO shall provide confidentiality protection for the locally stored event logs. + +**REQ-SEC-SMO-Log-6:** SMO shall provide integrity protection for the locally stored event logs. + +**REQ-SEC-SMO-Log-7:** SMO shall support access to event logs by authorized external services. + +**REQ-SEC-SMO-Log-8:** SMO shall be capable of forwarding event logs to an authorized remote location. + +**REQ-SEC-SMO-Log-9:** SMO shall be able to record all the security related log events. + +**REQ-SEC-SMO-Log-10:** The security logs of SMO should be separate from other system logs. + +**REQ-SEC-SMO-Log-11:** The SMO shall not permit configuration change to logging level(s) of any component on the SMO system without proper authorization. + +**REQ-SEC-SMO-Log-12:** SMO shall support access to event logs by authorized internal services. + +##### 5.1.1.1.5 NFO and FOCOM + +The below mentioned requirements are referring to securing the NFO and FOCOM in SMO. + +**REQ-SEC-NFO-FOCOM-1:** NFO and FOCOM shall support confidentiality, integrity, and anti-replay protection. + +**REQ-SEC-NFO-FOCOM-2:** Void + +**REQ-SEC-NFO-FOCOM-3:** NFO shall support mutual authentication with the O-Cloud DMS on the O2 interface. + +**REQ-SEC-NFO-FOCOM-4:** FOCOM shall support mutual authentication with the O-Cloud IMS on the O2 interface. + +**REQ-SEC-NFO-FOCOM-5:** NFO and FOCOM shall support authorization with the principle of least privilege for access attempts by O-Cloud service consumers, on a per-session basis. + +**REQ-SEC-NFO-FOCOM-6:** NFO shall be able to recover, without catastrophic failure, from a volumetric DDoS attack due to anomalous behaviour or malicious intent. + +**REQ-SEC-NFO-FOCOM-7:** Void + +**REQ-SEC-NFO FOCOM-8:** FOCOM shall be able to recover, without catastrophic failure, from a volumetric DDoS attack due to anomalous behaviour or malicious intent. + +#### 5.1.1.2 Security Controls + +##### 5.1.1.2.1 SMO + +**SEC-CTL-SMO-1:** SMO may support OAuth 2.0 authorization server and provide a token end-point, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +**SEC-CTL-SMO-2:** Void + +**SEC-CTL-SMO-3:** SMO shall support OAuth 2.0 resource owner/server, as specified in O-RAN Security Protocols Specifications [3], clause 4.7, for service requests received from other SMO functions. + +**SEC-CTL-SMO-4:** SMO shall support OAuth 2.0 client functionality, as specified in O-RAN Security Protocols Specifications [3], clause 4.7, for service requests to other SMO functions. + +**SEC-CTL-SMO-5:** SMO shall support mutual authentication of SMO functions using mTLS with PKI X.509v3 certificates as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-SMO-6:** SMO functions may support authentication of other SMO functions using TLS with pre-shared key (PSK) as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +##### 5.1.1.2.2 SMO Internal Communications + +![Diagram showing SMO Internal Communications between two SMO function blocks. A green double-headed arrow labeled 'mTLS or TLS-PSK' connects the two blocks, with the text 'SMO Internal Communications' below it.](f13e1b396f461742bad83e68d640ce10_img.jpg) + +``` + +graph LR + SMO1[SMO function] <-->|mTLS or TLS-PSK| SMO2[SMO function] + subgraph Interface + SMO1 --- SMO2 + end + Interface --- SMO_IC[SMO Internal Communications] + +``` + +Diagram showing SMO Internal Communications between two SMO function blocks. A green double-headed arrow labeled 'mTLS or TLS-PSK' connects the two blocks, with the text 'SMO Internal Communications' below it. + +**Figure 5.1.1.2.2-1: mTLS or TLS for SMO Internal Communications** + +**SEC-CTL-SMO-Internal-1:** For security protection at the transport layer, SMO Internal Communications shall support TLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-SMO-Internal-2:** For mutual authentication between SMO functions, SMO Internal Communications shall support mTLS, as shown in Figure 5.1.1.2.2-1 and specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-SMO-Internal-3:** For authentication between SMO functions, SMO Internal Communications may support TLS with pre-shared key (PSK), as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +##### 5.1.1.2.3 SMO External Interfaces + +External Interfaces not specified by O-RAN that provide services to SMO, acting in a consumer role, shall meet minimum security controls specified in this clause. + +![Diagram showing SMO External Interfaces between an SMO block and an External System block. A green double-headed arrow labeled 'mTLS' connects the two blocks, with the text 'SMO External Interface' below it. Inside the SMO block, there is a sub-block labeled 'External Termination'.](9628e333dc4d6f610dfb482a49d1c40c_img.jpg) + +``` + +graph LR + subgraph SMO_Box [SMO] + ET[External Termination] + end + ET <-->|mTLS| ES[External System] + subgraph Interface + SMO_Box --- ES + end + Interface --- SMO_EI[SMO External Interface] + +``` + +Diagram showing SMO External Interfaces between an SMO block and an External System block. A green double-headed arrow labeled 'mTLS' connects the two blocks, with the text 'SMO External Interface' below it. Inside the SMO block, there is a sub-block labeled 'External Termination'. + +**Figure 5.1.1.2.3-1: mTLS on SMO External interfaces** + +**SEC-CTL-SMO-External-1:** For confidentiality and integrity protection of data in transit, SMO External Interfaces shall support TLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-SMO-External-2:** For mutual authentication between the SMO and External Source, SMO External Interfaces shall support mTLS with PKI using X.509v3 certificates, as shown in Figure 5.1.1.2.3-1 and specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-SMO-External-3:** SMO External Interfaces shall support OAuth 2.0 resource owner/server, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +**SEC-CTL-SMO-External-4:** SMO External Interfaces shall support OAuth 2.0 client functionality, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +##### 5.1.1.2.4 SMO Logging + +**SEC-CTL-SMO-Log-1:** A SMO External Interface used for SMO log export shall support TLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2, and FTPES. + +**SEC-CTL-SMO-Log-2:** SMO log export may support SSH as specified in O-RAN Security Protocols Specifications [3], clause 4.1, and SFTP. + +**SEC-CTL-SMO-Log-3:** SMO log export shall support mutual authentication using mTLS with public key infrastructure (PKI) and X.509v3 certificates as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-SMO-Log-4:** When SSH is supported for SMO log export, SSH shall support authentication using public and private keys in a public key infrastructure (PKI). + +**SEC-CTL-SMO-Log-5:** When SSH is supported for SMO log export, SSH may support authentication using PKI and X.509v3 certificates. + +##### 5.1.1.2.5 NFO and FOCOM + +**SEC-CTL-NFO-FOCOM-1:** NFO shall support mutual authentication with O-Cloud DMS using mTLS with PKI X.509v3 certificates, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-NFO-FOCOM-2:** FOCOM shall support mutual authentication with O-Cloud IMS using mTLS with PKI X.509v3 certificates, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-NFO-FOCOM-3:** NFO shall support OAuth 2.0 resource owner/server as specified in O-RAN Security Protocols Specifications [3], clause 4.7, for service requests from O-Cloud resources. + +**SEC-CTL-NFO-FOCOM-4:** FOCOM shall support OAuth 2.0 resource owner/server, as specified in O-RAN Security Protocols Specifications [3], clause 4.7, for service requests from O-Cloud resources. + +**SEC-CTL-NFO-FOCOM-5:** NFO shall support OAuth 2.0 client functionality as specified in O-RAN Security Protocols Specifications [3], clause 4.7, for service requests to O-Cloud resources. + +**SEC-CTL-NFO-FOCOM-6:** FOCOM shall support OAuth 2.0 client functionality, as specified in O-RAN Security Protocols Specifications [3], clause 4.7, for service requests to O-Cloud resources. + +**SEC-CTL-NFO-FOCOM-7:** NFO shall support TLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2, on the O2 interface. + +**SEC-CTL-NFO-FOCOM-8:** FOCOM shall support TLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2, on the O2 interface. + +### 5.1.2 Non-RT RIC and rApps + +#### 5.1.2.1 Requirements + +rApp packages shall follow the security requirements and controls in clause 5.3.2.1. + +**REQ-SEC-NonRTRIC-1:** The Non-RT RIC shall support authorization as a resource owner/server and client. + +**REQ-SEC-NonRTRIC-2:** The Non-RT RIC Framework, as a resource owner/server, shall provide authorization to requests from rApps as a client. + +**REQ-SEC-NonRTRIC-3:** rApps shall provide client authorization requests to the Non-RT RIC Framework. + +**REQ-SEC-NonRTRIC-4:** The Non-RT RIC shall be able to recover, without catastrophic failure, from a volumetric DDoS attack across the A1 interface, due to misbehavior or malicious intent. + +**REQ-SEC-NonRTRIC-5:** The Non-RT RIC Framework shall be able to recover, without catastrophic failure, from a volumetric DDoS attack across the R1 interface, due to misbehavior or malicious intent. + +**REQ-SEC-NonRTRIC-6:** rApps shall be able to recover, without catastrophic failure, from a volumetric DDoS attack across the R1 interface, due to misbehavior or malicious intent. + +**REQ-SEC-NonRTRIC-7:** The SMO/Non-RT RIC Framework shall authenticate both API Producer and API Consumer across R1 interface using Kafka based protocol for data streaming. + +**REQ-SEC-NonRTRIC-8:** The SMO/Non-RT RIC Framework shall support authorization mechanism for Kafka based protocol to provision access for data streaming by API Producer and API Consumer across R1 interface. + +![Diagram showing the SMO/Non-RT RIC Framework supporting Kafka based protocol using TLS. The framework contains a DME component. It communicates with an rAPP component via Kafka using TLS. The communication is bidirectional, with arrows labeled 'Kafka using TLS'.](f12017b121db092f9fa1234fbe3e6fcb_img.jpg) + +``` + +graph LR + subgraph Framework [SMO/Non-RT RIC Framework] + DME[DME] + end + rAPP[rAPP] + DME -- "Kafka using TLS" --> rAPP + rAPP -- "Kafka using TLS" --> DME + +``` + +Diagram showing the SMO/Non-RT RIC Framework supporting Kafka based protocol using TLS. The framework contains a DME component. It communicates with an rAPP component via Kafka using TLS. The communication is bidirectional, with arrows labeled 'Kafka using TLS'. + +Figure 5.1.2.1-1: SMO/Non-RT RIC Framework supporting Kafka based protocol using TLS + +**REQ-SEC-NonRTRIC-9:** rAppIDs shall be unique within the Non-RT RIC runtime environment. + +**REQ-SEC-NonRTRIC-10:** rAppIDs shall be generated using strong randomization methods. + +NOTE: Strong randomization methods can help resist brute force attacks. + +#### 5.1.2.2 Security Controls + +**SEC-CTL-NonRTRIC-1:** For A1-EI, Non-RT RIC shall support OAuth 2.0 resource owner/server, as specified in O-RAN Security Protocols Specifications [3], clause 4.7, for service requests received from one or more Near-RT RICs. + +**SEC-CTL-NonRTRIC-2:** For A1-P, Non-RT RIC shall support OAuth 2.0 client, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +**SEC-CTL-NonRTRIC-3:** For R1, SMO/Non-RT RIC Framework shall support TLS, as specified in O-RAN Security Protocols Specifications [3]. + +**SEC-CTL-NonRTRIC-4:** For R1, SMO/Non-RT RIC Framework shall support authorization using OAuth 2.0, as specified in O-RAN Security Protocols Specifications. + +**SEC-CTL-NonRTRIC-5:** For R1, Non-RT RIC Framework shall support OAuth 2.0 resource owner/server functionality, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +**SEC-CTL-NonRTRIC-6:** For R1, rApps shall support OAuth 2.0 client functionality, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +### 5.1.3 Near-RT RIC and xApps + +#### 5.1.3.1 Requirements + +xApp packages shall follow the security requirements and controls in clause 5.3.2.1. + +**REQ-SEC-XAPP-1:** Void + +**REQ-SEC-XAPP-2:** Void + +**REQ-SEC-XAPP-3:** During the xApp registration procedure the xApp identifier (xApp ID) shall be associated with xApp credentials used for authentication. + +**REQ-SEC-XAPP-4:** xApp IDs shall be created ensuring uniqueness. + +**REQ-SEC-NEAR-RT-1:** Near-RT RIC shall authenticate xApp access to the Near-RT RIC database(s) during SDL registration. + +**REQ-SEC-NEAR-RT-2:** Near-RT RIC shall provide authorized access to Near-RT RIC database(s). + +**REQ-SEC-NEAR-RT-3:** The communication between xApps and Near-RT RIC platform APIs shall be mutually authenticated. + +**REQ-SEC-NEAR-RT-4:** Near-RT RIC architecture shall provide an authorization framework for the consumption of the services exposed in the platform APIs by the xApps, that takes operator policies into consideration. + +NOTE : The framework is used by the specified API procedures in [33]. + +**REQ-SEC-NEAR-RT-5:** The Near-RT RIC shall support authorization as a resource owner/server (A1-P) and client (A1-EI). + +**REQ-SEC-NEAR-RT-6:** The Near-RT RIC shall be able to recover, without catastrophic failure, from a volumetric DDoS attack across the A1 interface. + +**REQ-SEC-NEAR-RT-7:** The Near-RT RIC shall be able to detect and defend against content-related attacks across the A1 interface. + +NOTE 1: In practice, injection attacks and buffer overflow attacks are the most common classes of content-related attacks. + +**REQ-SEC-NEAR-RT-8:** The Near-RT RIC shall be able to detect and defend against content-related attacks across the Y1 interface. + +NOTE 2: In practice, injection attacks and buffer overflow attacks are the most common classes of content-related attacks. + +**REQ-SEC-NEAR-RT-9:** The Near-RT RIC shall be able to detect and defend against content-related attacks across the E2 interface. + +NOTE 3: In practice, injection attacks and buffer overflow attacks are the most common classes of content-related attacks. + +**REQ-SEC-NEAR-RT-10:** The Near-RT RIC shall support confidentiality, integrity and replay protection for the A1 interface. + +**REQ-SEC-NEAR-RT-11:** The Near-RT RIC shall support mutual authentication for the A1 interface. + +#### 5.1.3.2 Security Controls + +##### 5.1.3.2.1 API Security – Authentication + +**SEC-CTL-NEAR-RT-1:** Transactional APIs (REST and gRPC) shall support mutual TLS (mTLS) authentication via X.509v3 certificates as specified in the O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-NEAR-RT-2:** Time critical APIs, not supported by TLS protocol, shall support IPsec with IKEv2 certificate-based authentication according to O-RAN Security Protocols Specifications [3]. + +EXAMPLE: E2 related APIs are considered time critical APIs + +**SEC-CTL-NEAR-RT-2A:** The Near-RT RIC shall support mTLS as specified in O-RAN Security Protocols Specifications [3], clause 4.2, in order to provide mutual authentication for the A1 interface. + +##### 5.1.3.2.2 API Security – Authorization + +In the actual context of Near-RT RIC, the platform as API producer shall be responsible to specify those rights/privileges for the platform services as resources to the xApps as consumers. As a guideline, an xApp should only have the required set of permissions to perform the actions for which they are authorized, and no more. + +Authorization mechanisms shall be enforced by the Near-RT RIC platform in the following key API procedures [33]: + +- **Discovery of Near-RT RIC APIs:** The Near-RT RIC platform shall provide means to restrict xApps from discovery of some published APIs based on configuration policies. +- **E2 Subscription API procedure:** The subscription management shall be based on operator's policies. An xApp may be restricted to interface with only a subset of E2 Nodes by such policies. This procedure establishes a set of preconditions that assume authorization processes: + +- xApp has been authorized to issue E2 Subscription API requests +- xApp has been authorized to request guidance from Conflict mitigation +- xApp Subscription Management has been configured to permit E2 Subscription API requests only from specific list of xApps. +- **E2 Control API procedure:** Only authorized xApps may initiate RIC control request messages issued by the Near-RT RIC over the E2 interface to the E2 Nodes, for a specific scope. + +EXAMPLE 1: E2Nodes include E2 Node list, RAN function + +- **E2 Guidance API procedure:** Ensure only authorized xApp obtain guidance from the conflict mitigation platform function prior to initiating an action. +- **SDL API procedures:** xApps shall have been successfully registered and authorized prior to consuming the services exposed by SDL API. + +EXAMPLE 2: Services exposed by SDL API may be client registration, fetch data, notification, store + +**SEC-CTL-NEAR-RT-3:** Transactional APIs (REST and gRPC) in Near-RT RIC shall support OAuth 2.0 authorization framework as specified in in O-RAN Security Protocols Specifications [3], clause 4.7. + +The roles defined in OAuth 2.0 are assigned as follows: + +- Resource owner / Resource server (producer): Near-RT RIC platform modules providing services via APIs +- Client (consumer): xApp + +Grants shall be of the type Client Credentials Grant, as described in IETF RFC 6749 [34], clause 4.4. Mutual authentication using mTLS as specified in the O-RAN Security Protocols Specifications [3], clause 4.2 shall be used. + +**SEC-CTL-NEAR-RT-4:** For A1-P, Near-RT RIC shall support OAuth 2.0 resource owner/server, as specified in O-RAN Security Protocols Specifications [3], clause 4.7, for service requests received from a Non-RT RIC. + +**SEC-CTL-NEAR-RT-5:** For A1-EI, Near-RT RIC shall support OAuth 2.0 client, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +##### 5.1.3.2.3 API Security – Confidentiality and Integrity + +**SEC-CTL-NEAR-RT-6:** Transactional APIs (REST and gRPC) shall support TLS as specified in the O-RAN Security Protocols Specifications [3], clause 4.2 to provide message confidentiality and integrity. + +**SEC-CTL-NEAR-RT-7:** Time critical, not supported by TLS protocol, shall support IPsec as specified in the O-RAN Security Protocols Specifications [3], clause 4.5 to provide message confidentiality and integrity. + +Table 5-1 provides a summary of the security controls (SEC-CTL- NEAR-RT-1 to -7) and a mapping of those to the related interface/API transport protocols considered in Near-RT RIC platform. + +**Table 5-1: Summary of the Security Controls for Near-RT RIC APIs** + +| API protocol | Authentication method | Authorization method | Confidentiality method | Integrity method | +|--------------|-----------------------|----------------------|------------------------|------------------| +| gRPC | mTLS | OAuth2 | mTLS | mTLS | +| SCTP | IKEv2 | - | IPsec | IPsec | +| REST/HTTP | mTLS | OAuth2 | mTLS | mTLS | + +**SEC-CTL-NEAR-RT-8:** The Near-RT RIC shall verify policies received through the A1 interface as follows: + +- The policies conform to a pre-defined schema. +- The policy values are valid. + +- The policies are being received at or below a pre-defined rate. + +The Near-RT RIC shall log security event(s) if any of the policy verification steps fail. + +EXAMPLE: In practice, policy value validation verifies that values are within the predefined range + +**SEC-CTL-NEAR-RT-8A:** The Near-RT RIC shall support TLS as specified in O-RAN Security Protocols Specifications [3], clause 4.2, in order to provide confidentiality, integrity and replay protection for the A1 interface. + +##### 5.1.3.2.4 Security controls for the Y1 interface protocol structure solution 1 + +The Y1 interface protocol structure solution 1 is defined in the O-RAN ALLIANCE TS: "Y1 interface: General Aspects and Principles" [66], clause 7.2. + +**SEC-CTL-NEAR-RT-9:** The Near-RT RIC shall support mutual TLS (mTLS) authentication via X.509v3 certificates for the Y1 interface protocol structure solution 1, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +NOTE 1: In mTLS, both the client (the Y1 consumer) and the server (the Y1 provider) require a certificate, and both sides authenticate each other using their public/private key pair. + +**SEC-CTL-NEAR-RT-10:** The Near-RT RIC shall support the OAuth 2.0 authorization framework for the Y1 interface protocol structure solution 1 as specified in O-RAN Security Protocols Specifications [3], clause 4.7, in the role of a resource owner / resource server (producer). + +**SEC-CTL-NEAR-RT-11:** The Near-RT RIC shall support TLS for the Y1 interface protocol structure solution 1, as specified in O-RAN Security Protocols Specifications [3], clause 4.2, to provide data confidentiality, integrity, and replay-protection. + +##### 5.1.3.2.5 xApp Registration – Security procedure + +As part of the xApp registration procedure to the Near-RT RIC platform, the platform assigns an identity (ID) to the xApp, so called xApp ID. This xApp ID is used in xApp's API request messages to the Near-RT RIC platform to facilitate the Near-RT RIC platform the identification of the xApp (API service consumer). + +**SEC-CTL-NEAR-RT-12:** The xApp ID shall be embedded into the provided xApp X.509 certificate used for authentication (mTLS) according to the parametrization in [3], issued by operator RA/CA PKI infrastructure. + +NOTE 1: The security procedure to become part of the existing xApp registration procedure, specified in O-RAN ALLIANCE TS: "Near-RT RIC Architecture" [33], clause 9.1.4 where xApp ID is assigned, is detailed in the Figure 5.1.3.2-1. + +``` +@startuml +participant xapp as "xApp\n[API service consumer]" +participant nfo as "Provisioning system\n(NFO in SMO)" +participant pf as "Near-RT RIC platform \n(Operator RA functionality)\n[API service producer]" +participant pki as "Operator PKI\nCA" +xapp <- nfo : 1. Registration information\n[Near-RT RIC Platform\n(Address, Root CA Certificate),\n OAuth 2.0 Access token] +xapp -> pf : 2. TLS (Server side certificate based authentication) +note over xapp + 3. Generate the private/public key pair + and CSR +endnote +xapp -> pf : 4. Registration request (by xApp instance)\n[OAuth 2.0 access token, xApp Instance CSR] +note over pf + 5. Verify OAuth 2.0 access token + Generate the xApp ID + POP (Proof of Possession of Private Key) + RA policy: Add xApp ID to the request to be in the SAN field of the certificate +endnote +pf -> pki : 6. Request of the certificate by the RA +``` + +``` + +pf <- pki : 7. Issued certificate \n(embedded xApp ID in SAN) +rnote over pf + 8. Generate xApp MOI +endnote +xapp <- pf : 9. Registration Response (for xApp instance)\n[xApp ID, xApp Certificate, +(service API authentication \nand Authorization information)] +@enduml + +``` + +![Sequence diagram showing the security procedure for xApp registration. The diagram involves four main entities: xApp [API service consumer], Provisioning system (NFO in SMO), Near-RT RIC platform (Operator RA functionality) [API service producer], and Operator PKI CA. The process follows these steps: 1. Registration information (Near-RT RIC Platform (Address, Root CA Certificate), OAuth 2.0 Access token) is sent from the Provisioning system to the xApp. 2. TLS (Server side certificate based authentication) is established between the xApp and the Near-RT RIC platform. 3. The xApp generates a private/public key pair and CSR. 4. A registration request (by xApp instance) containing the OAuth 2.0 access token and xApp Instance CSR is sent to the Near-RT RIC platform. 5. The Near-RT RIC platform verifies the OAuth 2.0 access token, generates the xApp ID, POP (Proof of Possession of Private Key), and RA policy (Add xApp ID to the request to be in the SAN field of the certificate). 6. A request for the certificate is sent from the Near-RT RIC platform to the Operator PKI CA. 7. An issued certificate (embedded xApp ID in SAN) is received from the Operator PKI CA by the Near-RT RIC platform. 8. The Near-RT RIC platform generates the xApp MOI. 9. A registration response (for xApp instance) containing the xApp ID, xApp Certificate, (service API authentication and Authorization information) is sent from the Near-RT RIC platform back to the xApp.](1e6530e227e517d332e446ce96d41c7a_img.jpg) + +Sequence diagram showing the security procedure for xApp registration. The diagram involves four main entities: xApp [API service consumer], Provisioning system (NFO in SMO), Near-RT RIC platform (Operator RA functionality) [API service producer], and Operator PKI CA. The process follows these steps: 1. Registration information (Near-RT RIC Platform (Address, Root CA Certificate), OAuth 2.0 Access token) is sent from the Provisioning system to the xApp. 2. TLS (Server side certificate based authentication) is established between the xApp and the Near-RT RIC platform. 3. The xApp generates a private/public key pair and CSR. 4. A registration request (by xApp instance) containing the OAuth 2.0 access token and xApp Instance CSR is sent to the Near-RT RIC platform. 5. The Near-RT RIC platform verifies the OAuth 2.0 access token, generates the xApp ID, POP (Proof of Possession of Private Key), and RA policy (Add xApp ID to the request to be in the SAN field of the certificate). 6. A request for the certificate is sent from the Near-RT RIC platform to the Operator PKI CA. 7. An issued certificate (embedded xApp ID in SAN) is received from the Operator PKI CA by the Near-RT RIC platform. 8. The Near-RT RIC platform generates the xApp MOI. 9. A registration response (for xApp instance) containing the xApp ID, xApp Certificate, (service API authentication and Authorization information) is sent from the Near-RT RIC platform back to the xApp. + +**Figure 5.1.3.2-1: Security procedure for xApp registration** + +1. As a pre-requisite to the registration procedure, the xApp obtains information from a provisioning system (NFO in SMO) during the onboarding/deployment phase in the infrastructure. This information is used to authenticate and establish a secure TLS communication with the Near-RT RIC platform during the registration process. The information includes details of the Near-RT RIC platform (address, Root CA certificate) and includes an initial registration credential. + +NOTE 2: An OAuth 2.0 access token is provided as initial registration credential in the example. Other types of credentials in the initial registration can be used. + +2. The xApp and Near-RT RIC platform establish a TLS session (server-side certificate authentication) using the information obtained in step 1. + +3. The xApp generates the private and public key pair, and CSR (Certificate Signing Request). + +4. After successful establishment of the TLS session, the xApp instance sends a registration request message to the Near-RT RIC platform along with the pre-provisioned initial registration credential (OAuth 2.0 token), and the xApp instance CSR message. + +5. The Near-RT RIC platform shall validate the initial registration credential, and the Management Function of the platform shall generate an xApp ID for that particular xApp instance. At the reception of the CSR message from the xApp, the Registration Authority (RA), implemented in the Near-RT RIC platform, shall prove that the xApp instance is in possession of the private key. If the proof of possession procedure is positive, the RA shall configure a policy to add the xApp ID in the Subject Alt Name (SAN) field of the certificate request message to be forwarded to the Operator CA to fetch the end entity certificate. + +NOTE 3: The RA may use an enrolment protocol to fetch the certificate from the CA. The authentication mechanism between RA and CA are part of the operator PKI implementation. + +6. The RA requests the certificate for the xApp instance. + +7. Operator CA issues a certificate, embedding the xApp ID in SAN field of the certificate. The issued certificate by the operator CA will be used by the xApp for subsequent authentication and authorization procedures between the xApp and the Near-RT RIC platform when services/resources are consumed by xApps via APIs. + +8. The Near-RT RIC platform (Management Function) generates an xApp Managed Object Instance (MOI) as specified in [33], which may contain the mechanism for authentication (mTLS) and authorization (OAuth 2.0) between the xApp and the corresponding module of the Near-RT RIC platform. + +9. The Near-RT RIC platform (Management Function) responds with a xApp registration response message. The response shall include the assigned xApp ID, authentication, and authorization mechanism (if provided in step 8) and xApp certificate. + +**SEC-CTL-NEAR-RT-13:** The data type of the xApp ID shall be a string that uniquely identifies the xApp instance. The format of this string shall be a Universally Unique Identifier (UUID) version 4 as described in IETF RFC 4122 [77]. + +**SEC-CTL-NEAR-RT-14:** subjectAltName in the xApp instance certificate shall contain a URI-ID with the URI for the xApp ID as an URN; this URI-ID shall contain the xApp ID of the xApp instance using the UUID format as described in IETF RFC 4122 [77]. + +EXAMPLE 1: urn:uuid:f81d4fae-7dec-11d0-a765-00a0c91e6bf6 + +**SEC-CTL-NEAR-RT-15:** The Near-RT RIC shall verify data received through the Y1 interface as follows: + +- The data values are valid. +- The data is being received at or below a pre-defined message rate. + +EXAMPLE 2: In practice, data value validation verifies that values are within the predefined ranges. + +**SEC-CTL-NEAR-RT-16:** The Near-RT RIC shall log a security event each time an input validation step fails for data received through the Y1 interface. + +**SEC-CTL-NEAR-RT-17:** The Near-RT RIC shall verify data received through the E2 interface as follows: + +- The data values are valid. +- The data is being received at or below a pre-defined rate. +- The Near-RT RIC shall log security event(s) if any of the verification steps fail. + +EXAMPLE 3: In practice, data value validation verifies that values are within the predefined ranges. + +**SEC-CTL-NEAR-RT-18:** The Near-RT RIC platform shall verify data received from an xApp through E2 related APIs [33] as follows: + +- The data values are valid. +- The data is being received at or below a pre-defined rate. +- The Near-RT RIC shall log security event(s) if any of the verification steps fail. + +EXAMPLE 4: In practice, data value validation verifies that values are within the predefined ranges. + +### 5.1.4 O-CU-CP/UP + +#### 5.1.4.1 Requirements + +**REQ-SEC-OCU-1:** O-CU-CP and O-CU-UP shall meet the security requirements for gNB-CU-CP and gNB-CU-UP respectively, as specified in 3GPP TS 33.501[55]. + +#### 5.1.4.2 Security Controls + +**SEC-CTL-OCU-1:** O-CU-CP and O-CU-UP shall support the security controls for gNB-CU-CP and gNB-CU-UP respectively, as specified in 3GPP TS 33.501 [55]. + +### 5.1.5 O-DU + +#### 5.1.5.1 Requirements + +**REQ-SEC-ODU-1:** O-DU shall meet the security requirements for gNB-DU as specified in 3GPP TS 33.501[55]. + +The security requirements for the Open Fronthaul Interface are specified in clause 5.2.5. + +#### 5.1.5.2 Security Controls + +**SEC-CTL-ODU-1:** O-DU shall support the security controls for gNB-DU as specified in 3GPP TS 33.501[55]. The security controls for the Open Fronthaul Interface are specified in clause 5.2.5. + +### 5.1.6 O-RU + +#### 5.1.6.1 Requirements + +**REQ-SEC-ORU-1:** O-RU shall meet the security requirements for gNB setup and configuration as specified in 3GPP TS 33.501[55]. + +**REQ-SEC-ORU-2:** O-RU shall meet the security requirements for gNB secure environment as specified in 3GPP TS 33.501[55]. + +The security requirements for the Open Fronthaul Interface are specified in clause 5.2.5. + +#### 5.1.6.2 Security Controls + +The security controls for the Open Fronthaul Interface are specified in clause 5.2.5. + +### 5.1.7 O-eNB + +#### 5.1.7.1 Requirements + +**REQ-SEC-OeNB-1:** O-eNB shall meet the security requirements for eNB as specified in 3GPP TS 33.401[56]. + +#### 5.1.7.2 Security Controls + +**SEC-CTL-OeNB-1:** O-eNB shall support the security controls for eNB as specified in 3GPP TS 33.401[56]. + +### 5.1.8 O-Cloud + +#### 5.1.8.1 Generic requirements + +##### 5.1.8.1.0 Management Requirements for O-Cloud Platform + +Generic requirements for Cloud Platform Management are specified in [8]. + +##### 5.1.8.1.1 Requirements + +**REQ-SEC-OCLOUD-1:** Management Access to O-Cloud Platform shall be authenticated. + +**REQ-SEC-OCLOUD-2:** Management Access to O-Cloud Platform resources shall be authorized. + +**REQ-SEC-OCLOUD-3:** Means of isolation of control and resources among different subjects accessing the O-Cloud Platform shall be implemented. + +**REQ-SEC-OCLOUD-4:** O-Cloud Platform shall natively support Multi-Factor Authentication (MFA) or a third-party identity provider for secure management access [83]. + +##### 5.1.8.1.2 Security Controls + +**SEC-CTL-OCLOUD-1:** O-Cloud Platform should support access management to O-Cloud resources based on RBAC (Role-based access control) policies. + +**SEC-CTL-OCLOUD-2:** Void. + +#### 5.1.8.2 Application artifacts verification by the O-Cloud + +##### 5.1.8.2.1 Requirements + +**REQ-SEC-OCLOUD-IMG-1 to 18:** Void + +**REQ-SEC-OCLOUD-PKG-1:** Void + +**REQ-SEC-OCLOUD-PKG-2:** The O-Cloud shall support the capability of verifying the signature(s) of any application artifacts. + +**REQ-SEC-OCLOUD-PKG-3:** Void + +##### 5.1.8.2.2 Security Controls + +**SEC-CTL-OCLOUD-IMG-1 to 4:** Void + +NOTE: For implementation details of REQ-SEC-OCLOUD-PKG-2, refer to SEC-CTL-ALM-PKG-1A. + +#### 5.1.8.3 O-Cloud Platform Software Protection + +##### 5.1.8.3.0 Introduction + +The identified requirements and controls in this clause are enforcing the protection of O-Cloud Platform software during both initial deployment and subsequent updates. + +##### 5.1.8.3.1 Requirements + +**REQ-SEC-OCLOUD-SW-1:** All O-Cloud Platform software shall be protected to ensure its integrity and authenticity. + +###### **REQ-SEC-OCLOUD-SW-2:** Void + +##### **5.1.8.3.2 Security Controls** + +**SEC-CTL-OCLOUD-SW-1** For all deployments and updates, the O-Cloud shall verify the digital signature associated with the new O-Cloud Platform software before installing the software package. The algorithms, key sizes, and standards used for signature generation and verification shall adhere to the O-RAN Security Protocols Specifications [3], clause 5. + +#### **5.1.8.4 O-Cloud Virtualization and Isolation** + +##### **5.1.8.4.1 Introduction** + +This clause contains security requirements and controls to mitigate threats to O-Cloud Virtualization layer (Host OS-Hypervisor/Container engine/Cloud platform software components) and provide isolation to the Applications hosted on the O-Cloud. + +##### **5.1.8.4.2 Requirements** + +**REQ-SEC-OCLOUD-ISO-1:** O-Cloud Platform shall implement means of preventing privilege escalation by VNF/CNFs. + +**REQ-SEC-OCLOUD-ISO-2:** Void + +**REQ-SEC-OCLOUD-ISO-3:** The O-Cloud Platform shall ensure that VNF/CNFs have only the minimum required capabilities and privileges as well as minimum required access to the O-Cloud resources. + +**REQ-SEC-OCLOUD-ISO-4:** The O-Cloud Platform shall ensure strict isolation between VNF/CNFs for data in transit, data in use and data at rest. + +**REQ-SEC-OCLOUD-ISO-5:** Communication between O-Cloud Platform software components shall support confidentiality, integrity, and anti-replay protections for data in transit. + +**REQ-SEC-OCLOUD-ISO-6:** The O-Cloud Platform shall provide the capability to define network policies that restrict ingress and egress traffic and configure rate limiting between VNF/CNFs. + +**REQ-SEC-OCLOUD-ISO-7:** The O-Cloud Platform shall not permit configuration change of any component without proper authorization. + +##### **5.1.8.4.3 Security Controls** + +**SEC-CTL-O-CLOUD-ISO-1:** For mutual authentication between O-Cloud Platform software components, mTLS with PKI using X.509v3 certificates shall be supported as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-O-CLOUD-ISO-2:** For confidentiality and integrity protection of data in transit, O-Cloud Platform software components shall support TLS as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-O-CLOUD-ISO-3:** The O-Cloud Platform shall support an access control system to enforce access control policies that align with the principle of least privilege. + +#### 5.1.8.5 Secure update + +##### 5.1.8.5.0 Introduction + +The identified requirements and controls in this clause are enforcing the secure update of O-Cloud Platform software. + +##### 5.1.8.5.1 Requirements + +**REQ-SEC-OCLOUD-SU-1:** All software within the O-Cloud Platform shall be kept up to date with the last security updates for adding additional security protections and correcting vulnerabilities [i.1]. + +**REQ-SEC-OCLOUD-SU-2:** Void + +**REQ-SEC-OCLOUD-SU-3:** Void + +**REQ-SEC-OCLOUD-SU-4:** Void + +**REQ-SEC-OCLOUD-SU-5:** In case of an incomplete update, or incident during the installation process, the O-Cloud Platform shall remain in its initial working state. + +**REQ-SEC-OCLOUD-SU-6:** The O-Cloud Platform shall prevent the unauthorized rollback of its software to an earlier vulnerable version. + +**REQ-SEC-OCLOUD-SU-7:** The update of O-Cloud Platform software should be completed with minimal disruption and downtime. + +##### 5.1.8.5.2 Security Controls + +**SEC-CTL-OCLOUD-SU-1:** Void + +**SEC-CTL-OCLOUD-SU-2:** Void + +**SEC-CTL-OCLOUD-SU-3:** Void + +**SEC-CTL-OCLOUD-SU-4:** The O-Cloud Platform shall support the capability to detect and retrieve the latest security updates of the O-Cloud Platform software. + +**NOTE:** O-Cloud Platform software components can be consistently updated with the latest security patches for enhanced protection and vulnerability mitigation. The operation of this system can be automated. + +**SEC-CTL-OCLOUD-SU-5:** The O-Cloud Platform shall possess the capability to securely log and control software versions, thereby preventing unauthorized rollbacks to older, less secure software versions. + +**SEC-CTL-OCLOUD-SU-6:** The O-Cloud Platform should possess the capability to revert an O-Cloud Platform software component to its previous stable version in the event of an incomplete update or installation incident, ensuring operational continuity. + +**SEC-CTL-OCLOUD-SU-7:** The O-Cloud Platform should be designed for redundancy and high availability, to maintain uninterrupted service during both the update process and in scenarios of unexpected update failures. + +#### 5.1.8.6 Secure Protection of cryptographic keys and sensitive data + +##### 5.1.8.6.1 Requirements + +**REQ-SEC-OCLOUD-SS-1:** Sensitive data within the O-Cloud platform shall be protected in terms of integrity and confidentiality at rest, in use and in transit. + +**REQ-SEC-OCLOUD-SS-2:** The O-Cloud platform shall support a secure deletion method from both active and backup storage medias. + +**REQ-SEC-OCLOUD-SS-3:** The O-Cloud platform shall ensure that any data contained in a resource is not available when the resource is de-allocated from one VM/Container and reallocated to a different VM/Container. + +NOTE 1: This requirement requires protection for any data contained in a resource that has been logically deleted or released but may still be present within the resource which in turn may be re-allocated to another VM/Container. + +**REQ-SEC-OCLOUD-SS-4:** The O-Cloud platform shall have the capability that allows an Application to securely erase sensitive data owned by the Application. + +**EXAMPLE:** Sensitive data includes, but is not limited to, cryptographic keys, personally identifiable information (PII), credentials, tokens, and configuration data. + +**REQ-SEC-OCLOUD-SS-5:** The secure deletion method should activate automatically during the boot process after a power outage to prevent unauthorized access to any residual data from all volatile memories, including RAM and cache. + +NOTE 2: Data may linger in volatile memory for a short period after power is lost, potentially allowing for data recovery through cold boot attacks if the system is quickly powered back on. + +See Annex C for the guidance to implement REQ-SEC-OCLOUD-SS-5. + +##### 5.1.8.6.2 Security Controls + +**SEC-CTL-OCLOUD-SS-1:** The O-Cloud data storage shall support encryption of data at rest. + +**SEC-CTL-OCLOUD-SS-2:** The O-Cloud shall support the capability for secure deletion of data in addressable memory locations that are no longer in use due to reallocation. + +NOTE: This includes the ability to overwrite these locations with specific binary patterns, such as zeroes, ones, or a random bit pattern. + +**SEC-CTL-OCLOUD-SS-3:** Medias containing sensitive information shall be sanitized using media-specific techniques. + +See Annex C for the guidance to implement these controls. + +#### 5.1.8.7 Chain of Trust + +##### 5.1.8.7.1 Requirements + +**REQ-SEC-OCLOUD-COT-1:** The O-Cloud platform shall support a root of trust that verifies the integrity of every relevant component in the O-Cloud platform, see [i.1], [i.2] and [i.3]. + +**REQ-SEC-OCLOUD-COT-2:** It shall be possible to attest an O-RAN Application through the full attestation chain from the hardware layer through the virtualization layer to the O-RAN Application layer, see [i.15] and [49]. + +**REQ-SEC-OCLOUD-COT-3:** The O-Cloud shall support X.509v3 certificates issued by the Service Provider CA for the O2 interface [6]. + +**REQ-SEC-OCLOUD-COT-4:** The O-Cloud shall support management of the certificates signed by the Service Provider PKI for the O2 interface through a certificate management protocol. + +##### 5.1.8.7.2 Security Controls + +**SEC-CTL-OCLOUD-COT-1:** The chain of trust shall be built from measurements stored in a hardware root of trust. + +**SEC-CTL-OCLOUD-COT-2:** The chain of trust shall be built from measurements stored in a software root of trust for scenarios where a hardware root of trust is not feasible or available. + +**SEC-CTL-OCLOUD-COT-3:** A remote attestation service (AS) should be supported for providing additional benefits beside verifying O-Cloud platform integrity by CoT. The remote AS should collect O-Cloud platform configurations and integrity measurements from data center servers at an O-Cloud service provider via a trust agent service running on + +the O-Cloud platform servers [i.7]. The O-Cloud service provider is responsible for defining allowlisted trust policies. These policies should include information and expected measurements for desired platform CoT technologies. The collected data is compared and verified against the policies, and a report is generated to record the relevant trust information in the AS database [i.7]. The remote AS should be extended to include O-RAN Applications integrity. + +See Annex C for the guidance to implement these controls. + +#### 5.1.8.8 AAL + +There are two different scenarios of deployment of the hardware accelerator manager: + +- Scenario 1: the hardware accelerator manager is a SW component part of the O-Cloud platform and outside the hardware accelerator device. It is linked to the hardware accelerator device via a vendor specific interface. +- Scenario 2: The hardware accelerator manager is part of the hardware accelerator device. In this scenario, the vendor specific interface does not exist. + +For both scenarios, AALI-C-Mgmt interface is the same between the hardware accelerator manager and the O-Cloud IMS/DMS. + +AAL components are parts of the O-Cloud platform, therefore the O-Cloud security requirements and controls on image protection, secure update, isolation, secure storage, and chain of trust shall apply to AAL components, see clause 5.1.8. + +##### 5.1.8.8.1 Requirements and Security Controls on AAL interfaces + +###### 5.1.8.8.1.1 AALI-C-Mgmt + +###### 5.1.8.8.1.1.1 Requirements + +**REQ-SEC-AALI-C-Mgmt-1:** The hardware accelerator manager shall authenticate O-Cloud IMS/DMS when O-Cloud IMS/DMS initiates a communication to the hardware accelerator manager over AALI-C-Mgmt interface. + +**REQ-SEC-AALI-C-Mgmt-2:** The hardware accelerator manager shall check whether O-Cloud IMS/DMS is authorized when O-Cloud IMS/DMS accesses the hardware accelerator manager. + +**REQ-SEC-AALI-C-Mgmt-3:** AALI-C-Mgmt interface shall support confidentiality, integrity, and replay protection between the hardware accelerator manager and O-Cloud IMS/DMS. + +###### 5.1.8.8.1.1.2 Security Controls + +**SEC-CTL-AALI-C-Mgmt-1:** AALI-C-Mgmt interface shall support TLS as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-AALI-C-Mgmt-2:** For mutual authentication between the hardware accelerator manager and O-Cloud IMS/DMS, AALI-C-Mgmt interface shall support mTLS with PKI using X.509v3 certificates as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-AALI-C-Mgmt-3:** AALI-C-Mgmt interface shall support authorization using OAuth 2.0, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +###### 5.1.8.8.1.2 Vendor specific interface + +###### 5.1.8.8.1.2.1 Requirements + +The following requirements apply only for Scenario 1. + +**REQ-SEC-AAL-VS-1:** The hardware accelerator device shall authenticate the hardware accelerator manager when the hardware accelerator manager initiates a communication to the hardware accelerator device over the vendor specific interface. + +**REQ-SEC-AAL-VS-2:** The hardware accelerator manager shall check whether the hardware accelerator device is authorized when the hardware accelerator manager accesses the hardware accelerator device. + +**REQ-SEC-AAL-VS-3:** The vendor specific interface shall support integrity between the hardware accelerator manager and the hardware accelerator device. + +**REQ-SEC-AAL-VS-4:** The vendor specific interface may support confidentiality and replay protection between the hardware accelerator manager and the hardware accelerator device. + +NOTE: The implementation of confidentiality and replay protection over the vendor specific interface depends on the capacity/capability of the hardware accelerator device. + +##### 5.1.8.8.2 Specific Requirements and Security Controls on AAL components + +###### 5.1.8.8.2.1 Requirements + +**REQ-SEC-AAL-1:** The hardware accelerator device shall provide the capability for memory to be cleared securely prior to allocation or when indicated by the AAL Application on returning the memory. + +**REQ-SEC-AAL-2:** The AAL Implementation shall clear memory prior to allocation or when indicated by the AAL Application on returning the memory. + +**REQ-SEC-AAL-3:** The hardware accelerator device shall have a unique identity for a proper identification and tracking of the hardware accelerator device by the hardware acceleration manager. + +NOTE: This requirement allows the O-Cloud platform for proper identification and tracking of the accelerator, as well as ensuring that it is not tampered with or replaced without proper authorization. + +**REQ-SEC-AAL-4:** Hardware accelerators should be procured from vendors who can demonstrate the security of their supply chain and manufacturing processes (supply chain security). + +**REQ-SEC-AAL-5:** The hardware accelerator device shall provide the capability for fine grained memory access control. An AAL Application or AAL Profile Instance access shall be restricted to only given buffer(s), and access requests outside that buffer(s) shall fail. + +**REQ-SEC-AAL-6:** The Hardware accelerator manager shall log security events to track and monitor any potential security incidents and to ensure accountability. Such security events include: + +- Hardware accelerator failures. +- Hardware accelerator configuration changes. +- Hardware accelerator software update and boot process. +- Hardware accelerator access attempts by unauthorized users/systems, network connectivity issues, successful authentication/authorization events. +- Hardware accelerator performance issues or degradation. + +###### 5.1.8.8.2.2 Security Controls + +**SEC-CTL-AAL-1:** The clear memory mechanism should involve overwriting data that was previously stored in the memory with a known pattern, such as all zeros or a random value, to memory buffers. + +**SEC-CTL-AAL-2:** Supply chain audit of hardware accelerator vendors should be performed for establishing trust in vendor's supply chain management based on evidence presented. + +NOTE: The evidence can be of different forms and some of them are described below. + +- Process to identify and map the hardware accelerator components of each hardware accelerator to the sourcing information. + +- A repeatable process of procuring components for building hardware accelerator. +- Ability and procedures to detect counterfeit hardware components. +- Procedures with strict access control measures for hardware accelerator inventory storage, transport, and distribution. + +#### 5.1.8.9 O2dms/O2ims/O-Cloud Notification APIs + +##### 5.1.8.9.1 Requirements + +###### 5.1.8.9.1.1 O2dms + +**REQ-SEC-OCLOUD-O2dms-1:** O-Cloud DMS shall authenticate SMO (NFO or any other entity using O2dms) when SMO initiates a communication to O-Cloud for the deployment and management of Applications over O2dms interface. + +**REQ-SEC-OCLOUD-O2dms-2:** O-Cloud DMS shall be able to establish securely protected connection in terms of confidentiality, integrity, and anti-replay with the SMO (NFO or any other entity using O2dms) over the O2dms interface. + +**REQ-SEC-OCLOUD-O2dms-3:** O-Cloud DMS shall check whether SMO (NFO or any other entity using O2dms) has been authorized when SMO access O-Cloud for the deployment and management of Applications. + +**REQ-SEC-OCLOUD-O2dms-4:** O-Cloud DMS shall log SMO's management operations for auditing. + +###### 5.1.8.9.1.2 O2ims + +**REQ-SEC-OCLOUD-O2ims-1:** O-Cloud IMS shall authenticate SMO (FOCOM or any other entity using O2ims) when SMO initiates a communication to O-Cloud for the management of infrastructure over O2ims interface. + +**REQ-SEC-OCLOUD-O2ims-2:** O-Cloud IMS shall be able to establish securely protected connection in terms of confidentiality, integrity, and anti-replay with the SMO (FOCOM or any other entity using O2ims) over the O2ims interface. + +**REQ-SEC-OCLOUD-O2ims-3:** O-Cloud IMS shall check whether SMO (FOCOM or any other entity using O2ims) has been authorized when SMO access the O-Cloud infrastructure. + +**REQ-SEC-OCLOUD-O2ims-4:** O-Cloud IMS shall log SMO's management operations for auditing. + +###### 5.1.8.9.1.3 O-Cloud Notification API + +**REQ-SEC-O-CLOUD-NotifAPI-1:** The communication between Applications and the O-Cloud platform through the O-Cloud Notification API shall be mutually authenticated. + +**REQ-SEC-O-CLOUD-NotifAPI-2:** The O-Cloud platform shall provide an authorization framework for the consumption of the services exposed in the O-Cloud Notification API by Applications. + +##### 5.1.8.9.2 Security Controls + +**SEC-CTL-O-CLOUD-INTERFACE-1:** For the security protection at the transport layer on O2 interface, TLS shall be supported, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-O-CLOUD-INTERFACE-2:** For the authorization of O2 RESTful and O-Cloud Notification APIs requests and notifications, OAuth 2.0 shall be supported, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +**NOTE:** In the actual context of O-Cloud, the platform as API producer is responsible to specify those rights/privileges for the platform services as resources to Applications as consumers. As a guideline, an Application should only have the required set of permissions to perform the actions for which they are authorized, and no more. + +Authorization mechanisms are enforced by the O-Cloud platform for subscriptions to events/status from the O-Cloud. + +**SEC-CTL-O-CLOUD-INTERFACE-3:** For the mutual authentication between O-Cloud platform and Applications, and between O-Cloud platform and SMO, O2 interface and O-Cloud Notification APIs shall support mutual TLS (mTLS) authentication via X.509v3 certificates, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +#### 5.1.8.10 O-Cloud secure environment + +##### 5.1.8.10.1 Introduction + +This clause contains security requirements and controls on the O-Cloud secure environment to protect sensitive data. + +##### 5.1.8.10.2 Requirements + +**REQ-SEC-O-CLOUD-HW-1:** Void + +**REQ-SEC-O-CLOUD-SE-1:** O-Cloud secure environment shall include measures to counteract unauthorized extraction or inference of sensitive information using physical methods. + +**REQ-SEC-O-CLOUD-SE-2:** O-Cloud secure environment shall include measures to counteract side-channel attacks and prevent unauthorized inference of sensitive information. + +**NOTE:** + +- REQ-SEC-O-CLOUD-SE-1 addresses direct physical attacks that require physical access to the O-Cloud secure environment. This involves tampering, probing, or other forms of physical interference. +- REQ-SEC-O-CLOUD-SE-2 focuses on side-channel attacks, which exploit indirect information leakage without requiring physical access. This involves analysing timing, power consumption, or electromagnetic (EM) emissions. + +##### 5.1.8.10.3 Security Controls + +**SEC-CTL-O-CLOUD-HW-1:** Void + +#### 5.1.8.11 O-Cloud instance ID + +##### 5.1.8.11.0 Introduction + +The following set of requirements and controls outlines the essential criteria concerning the O-Cloud instance ID. This ID is a cornerstone for uniquely identifying and managing various components, including VMs, pods, containers, nodes, and compute pools within the O-Cloud platform. Safeguarding its global uniqueness, preserving its confidentiality and integrity, and controlling its accessibility are crucial to prevent conflicts, unauthorized access, and potential system compromises. + +##### 5.1.8.11.1 Requirements + +**REQ-SEC-OCLOUD-INST-ID-1:** The O-Cloud instance ID shall be unique within the O-Cloud platform to prevent conflicts and ensure accurate identification. + +**REQ-SEC-OCLOUD-INST-ID-2:** The O-Cloud instance ID shall not be exposed in public-facing interfaces, APIs, or logs without proper authentication and authorization mechanisms in place. + +**REQ-SEC-OCLOUD-INST-ID-3:** The O-Cloud instance ID shall be protected to ensure confidentiality and integrity, both during storage (at rest) and while being transmitted (in transit). + +**REQ-SEC-OCLOUD-INST-ID-4:** The O-Cloud instance ID shall be subject to auditing and monitoring, with detailed logs maintained to track activities related to the instance's creation, usage, modification, and deletion. + +**REQ-SEC-OCLOUD-INST-ID-5:** The O-Cloud instance ID shall be associated with a single component, be it a VM, container, pod, node, or compute pool, to ensure clear resource ownership, traceability, and accountability. + +##### 5.1.8.11.2 Security Controls + +**SEC-CTL-OCLOUD-INST-ID-1:** O-Cloud instance IDs shall be generated using strong randomization methods to ensure a high degree of uniqueness and minimize the likelihood of collisions. + +**EXAMPLE:** Implementation (Kubernetes-specific) + +Kubernetes generates unique instance IDs, called Pod names, by combining factors like pseudorandom number generators (PRNGs) and contextual information. PRNGs use an initial seed and deterministic algorithms to produce random-like numbers. These numbers, along with contextual elements like timestamps and namespace identifiers, form the basis of the Pod names. This approach ensures that generated names are non-guessable, unpredictable, and unlikely to collide within the Kubernetes cluster. The combination of PRNGs, randomization, and context guarantees that instance IDs are secure, unique, and suitable for identifying pods within the system. + +**SEC-CTL-OCLOUD-INST-ID-2:** O-Cloud should validate newly generated instance IDs against existing IDs to guarantee uniqueness before finalizing instance creation. + +#### 5.1.8.12 Time Synchronization and Consistency Requirements for O-Cloud + +##### 5.1.8.12.0 Introduction + +The requirements listed below highlight the O-Cloud's focus on creating a secure time synchronization framework with NTP as the focus. The requirement and security controls below in this clause are not applicable to PTP. By ensuring each node of the O-Cloud connects to a trusted and authenticated time source, O-Cloud aims to enhance its defences against threats such as clock manipulation, data inconsistencies and operational disruptions. + +##### 5.1.8.12.1 Requirements + +**REQ-SEC-OCLOUD-TS-1:** All O-Cloud nodes shall be configured to connect to a secure and authenticated time synchronization server for ToD synchronization. + +**REQ-SEC-OCLOUD-TS-2:** The O-Cloud shall be configured such that ToD synchronization is maintained across all nodes in an O-Cloud compute pool, there by guaranteeing uniform time references for all applications hosted on these nodes. + +**REQ-SEC-OCLOUD-TS-3:** The O-Cloud shall guarantee that the timestamp consistency is preserved even when applications are relocated across different nodes of the O-Cloud infrastructure. + +**NOTE 1:** Timestamp refers to: + +1. **Log/event timestamps:** These are associated with each log entry generated. Examples include application start/stop, application relocation, node failures, network events, change in applications and O-Cloud configuration, resource allocation, deallocation, etc. +2. **Data Transaction timestamps:** For applications that rely on time-sensitive data within O-Cloud, consistent timestamps are crucial. Whenever data is read, written, or modified, a timestamp is generated to ensure both data integrity and consistency across nodes. + +**REQ-SEC-OCLOUD-TS-4:** The O-Cloud shall guarantee that various instances of an identical application, irrespective of their location, generate logs with consistent timestamps. + +**NOTE 2:** Within the O-Cloud infrastructure, a "consistent timestamp" denotes the synchronized and uniform chronological markers generated by various instances of an identical application, irrespective of their location. This uniformity ensures that aggregated or analysed logs from different instances present a coherent chronological sequence, aiding in precise event correlation and analysis. To achieve and maintain this consistency, it's recommended for O-Cloud to synchronize its internal clocks with trusted time sources, such as NTP servers, guaranteeing both the accuracy and trustworthiness of these timestamps. + +**REQ-SEC-OCLOUD-TS-5:** All O-Cloud nodes within a compute pool, especially those serving a specific geographic region or co-located, shall be configured to operate using a consistent time reference, preferably UTC with a Time Zone (TZ) modifier. + +**NOTE 3:** This requirement ensures: + +1. **Uniformity in Time-Related Operations:** Simplifies the process of correlating logs, events, and time-sensitive operations across nodes, aiding in quicker identification of anomalies or malicious activities. +2. **Operational Consistency:** Ensures that scheduled tasks, backups, updates, or maintenance activities are executed consistently across the compute pool. +3. **Data Integrity:** Provides consistency for applications and databases that rely on timestamps for transactions, ensuring no discrepancies due to time differences. + +##### 5.1.8.12.2 Security Controls + +**SEC-CTL-OCLOUD-TS-1:** The O-Cloud shall ensure that all nodes are configured to exclusively connect to a secure and authenticated time synchronization server for Time of Day (ToD) synchronization. + +**EXAMPLE 1:** NTP Usage + +The O-Cloud should primarily use the Network Time Protocol (NTP) for general time synchronization needs, ensuring consistent timestamps for operations such as logging security events. This connection should prioritize the use of NTP with authentication mechanisms in place to ensure the integrity and authenticity of the time data. The authentication mechanisms provided by NTPv4 should be employed for NTP. This includes the use of symmetric key cryptography to authenticate the time server. Additionally, consideration will be given to implementing NTP over MACsec to enhance security, ensuring the confidentiality and integrity of the time synchronization data. + +**SEC-CTL-OCLOUD-TS-2:** All O-Cloud nodes shall be configured to synchronize their clocks exclusively with centralized time servers at regular intervals to ensure uniformity in time-related operations and data across the O-Cloud infrastructure. + +**EXAMPLE 2:** Time synchronization protocol such as NTP can be used to achieve this consistency. + +NTP: While NTP provides millisecond-level accuracy, it's widely adopted and can be sufficient for many applications in the O-Cloud. The reference points here would be the stratum 1-time servers or atomic clocks that NTP servers synchronize with. + +**SEC-CTL-OCLOUD-TS-3:** The O-Cloud should establish multiple time servers for redundancy. This ensures that nodes can switch to an alternative trusted server if the primary server becomes unavailable, thereby maintaining consistent time synchronization. + +**EXAMPLE 3:** NTP Redundancy + +By configuring nodes to have a list of NTP servers, they can automatically switch to a secondary or tertiary server if the primary server fails. This ensures continuous time synchronization and mitigates the risk of a single point of failure. + +**NOTE:** See clause 5.3.8.9.2 for additional security controls. + +#### 5.1.8.13 Security policies enforcement + +##### 5.1.8.13.1 Introduction + +The following security requirements apply to the O-Cloud to enforce security policies that may be defined in deployment descriptors. + +The activation or deactivation of these security policies is operator dependent, making their support mandatory but their use optional depending on operational needs. + +##### 5.1.8.13.2 Requirements + +**REQ-SEC-OCLOUD-SECPOL-1:** The O-Cloud Platform should verify that the source of any container or VM image is trusted before deployment. + +**REQ-SEC-OCLOUD-SECPOL-2:** The O-Cloud Platform should enforce resource quotas and limits by ensuring that the specified quotas and limits in the deployment descriptor are applied and maintained at each container or VM level. + +**REQ-SEC-OCLOUD-SECPOL-3:** The O-Cloud Platform should ensure that containers and VMs run with restricted privileges, preventing any processes from having elevated privileges unless explicitly required and approved. + +**REQ-SEC-OCLOUD-SECPOL-4:** The O-Cloud Platform should allow only approved storage resource types to be mounted for containers and VMs. + +**NOTE 1:** In the context of containers, storage resources refer to volumes. In the context of VMs, storage resources refer to disks or storage drives. + +**REQ-SEC-OCLOUD-SECPOL-5:** The O-Cloud Platform should enforce that containers and VMs use a read-only root file system, preventing modifications to critical system files during runtime. + +**REQ-SEC-OCLOUD-SECPOL-6:** The O-Cloud Platform should enforce immutability by ensuring that containers and VMs are always deployed using the latest verified images from trusted image repositories, preventing the reuse of cached images on nodes. + +**REQ-SEC-OCLOUD-SECPOL-7:** The O-Cloud Platform should enforce defined network policies to manage and control ingress and egress traffic, ensuring that only authorized traffic is permitted within and across the O-Cloud infrastructure. + +**REQ-SEC-OCLOUD-SECPOL-8:** The O-Cloud Platform should enforce workload placement policies. + +NOTE 1: + +- For containers, this can be achieved using taint and toleration policies. +- For VMs, this can be enforced through resource scheduling policies or affinity/anti-affinity rules. + +**EXAMPLE:** This requirement could, for instance, ensure that an O-DU is scheduled on a node that supports the required AAL, or that O-DU is deployed on a node equipped with a TPM for secure operations. + +**NOTE 2:** The implementation of security policies depends on the underlying technology, whether it involves containerization or virtualization. Guidance for implementing these security policies using Kubernetes admission controllers is provided in Annex C.1.3, based on Kubernetes and OpenShift documentation [i.21], [i.22]. + +### 5.1.9 Shared O-RU + +#### 5.1.9.0 Introduction + +Shared O-RU security requirements are consistent with O-RU security requirements in clause 5.1.6 and applicable in a Shared O-RU configuration, which introduces additional security requirements. + +#### 5.1.9.1 Security Requirements + +**REQ-SEC-SharedORU-1:** The Shared O-RU shall mutually authenticate with an O-RU Controller. + +**REQ-SEC-SharedORU-2:** The Shared O-RU shall provide least privilege access to each SRO based upon its sro-id. + +**REQ-SEC-SharedORU-3:** The Shared O-RU shall provide separate confidentiality and integrity protection of data-at-rest for the SOH and each SRO. + +**REQ-SEC-SharedORU-4:** The Shared O-RU shall provide separate confidentiality, integrity, and replay protection for data-in-transit for the SOH and each SRO. + +**REQ-SEC-SharedORU-5:** Void + +**REQ-SEC-SharedORU-6:** Void + +**REQ-SEC-SharedORU-7:** The Shared O-RU shall be able to recover, without catastrophic failure, from a volumetric DDoS attack due to misbehavior or malicious intent. + +**REQ-SEC-SharedORU-8:** The Shared O-RU shall support event logging with tenant-awareness. + +#### 5.1.9.2 Security Controls + +**SEC-CTL-SharedORU-1:** The Shared O-RU shall support mTLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2, with PKI using X.509v3 certificates for mutual authentication on the M-Plane interface with an O-RU Controller. + +**SEC-CTL-SharedORU-2:** The Shared O-RU should not use password-based authentication with an O-RU Controller. + +**SEC-CTL-SharedORU-3:** The Shared O-RU shall support NACM for permitting or denying access to an SRO. + +**SEC-CTL-SharedORU-4:** The Shared O-RU shall support TLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2, for confidentiality and integrity protection of data-in-transit on the M-Plane interface with an O-RU Controller. + +## 5.2 Interfaces maintained by O-RAN + +### 5.2.1 A1 Interface + +#### 5.2.1.0 Introduction + +The A1 Interface is defined in the A1 specifications [5]. + +#### 5.2.1.1 Requirements + +**REQ-SEC-A1-1:** A1 interface shall support confidentiality, integrity, replay protection. + +**REQ-SEC-A1-2:** A1 interface shall support mutual authentication. + +**REQ-SEC-A1-3:** A1 interface shall support authorization with the principle of least privilege. + +#### 5.2.1.2 Security Controls + +![Diagram showing the A1 interface between a Non-RT RIC and multiple Near RT RICs. The Non-RT RIC is connected to two Near RT RICs via A1 interfaces. The connections are labeled with A1 and mTLS, indicating mutual TLS security.](66ff70158ea08d31c04d27e923f27838_img.jpg) + +``` + +graph LR + Non-RT-RIC[Non-RT RIC] -- A1 --> Near-RT-RIC1[Near RT RIC] + Non-RT-RIC -- A1 --> Near-RT-RIC2[Near RT RIC] + Near-RT-RIC1 -- mTLS --> Non-RT-RIC + Near-RT-RIC2 -- mTLS --> Non-RT-RIC + style Near-RT-RIC1 fill:none,stroke:none + style Near-RT-RIC2 fill:none,stroke:none + style Non-RT-RIC fill:none,stroke:none + style mTLS fill:none,stroke:none + style A1 fill:none,stroke:none + +``` + +Diagram showing the A1 interface between a Non-RT RIC and multiple Near RT RICs. The Non-RT RIC is connected to two Near RT RICs via A1 interfaces. The connections are labeled with A1 and mTLS, indicating mutual TLS security. + +Figure 5.2.1.2-1: mTLS on A1 interface + +**SEC-CTL-A1-1:** For the security protection at the transport layer on A1 interface, TLS shall be supported, as specified in O-RAN Security Protocols Specifications [3] clause 4.2. + +**SEC-CTL-A1-2:** For the mutual authentication of the Non-RT RIC and one or more Near-RT RICs, the A1 interface shall support mTLS with PKI using X.509v3 certificates, as shown in Figure 5.2.1.2-1 and specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-A1-3:** The A1 interface shall support authorization using OAuth 2.0, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +### 5.2.2 O1 Interface + +#### 5.2.2.0 Introduction + +O1 interface connects the SMO to each NF. + +#### 5.2.2.1 Requirements + +**REQ-SEC-O1-1:** O1 interface shall support confidentiality, integrity, and replay protection. + +**REQ-SEC-O1-2:** O1 interface shall support mutual authentication. + +**REQ-SEC-O1-3:** O1 interface shall support authorization using the principle of least privilege. + +##### 5.2.2.1.1 Summary + +Void + +##### 5.2.2.1.2 Confidentiality, Integrity and Authenticity + +**REQ-TLS-FUN-1:** Void + +**REQ-TLS-FUN-2:** Void. + +**REQ-TLS-FUN-3:** Void + +**REQ-TLS-FUN-4:** Void + +##### 5.2.2.1.3 Least Privilege Access Control + +Void + +#### 5.2.2.2 Security Controls + +**SEC-CTL-01-1:** O1 interface shall support confidentiality and integrity protection using TLS, as specified in O-RAN Security Protocols Specifications [3] clause 4.2. + +**SEC-CTL-01-2:** O1 interface shall support mutual authentication using mTLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-01-3:** O1 producers and consumers that use NETCONF shall support authorization and least privilege using NACM, as specified in clause 5.2.2.3. + +**SEC-CTL-01-4:** The O1 interface in a Shared O-RU configuration shall support confidentiality and integrity protection using TLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-01-5:** The O1 interface in a Shared O-RU configuration shall support mutual authentication using mTLS , as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +#### 5.2.2.3 Configuration Requirements for Least Privilege Access + +**REQ-NAC-FUN-1:** O1 producers and consumers that use NETCONF shall support the NETCONF Access Control Model (NACM) as specified in RFC 8341 [10] to restrict NETCONF protocol access for users to a preconfigured subset of available NETCONF protocol operations and content. + +**REQ-NAC-FUN-2:** The NETCONF implementation for O1 shall set the default values of the NACM Global Enforcement Controls as described in Table 5.2.2.3-1 + +**Table 5.2.2.3-1: Default values of the NACM Global Enforcement** + +| Parameter | Value | +|------------------------|-------| +| enable-nacm | true | +| read-default | deny | +| write-default | deny | +| exec-default | deny | +| enable-external-groups | true | + +**REQ-NAC-FUN-3:** Management Service providers that support NETCONF shall support the following pre-defined groups in NACM to restrict NETCONF protocol access for users. + +- O1\_nacm\_management: Allows changes to the /nacm objects which includes the NACM Global Enforcement Controls. Allowing changes to the NACM Global Enforcement Controls configuration is optional. +- O1\_user\_management: Allows assignment and deletion of users and assignment of users to roles on the O1 node. + - **Mandatory** if the network device supports a local user store. + - **Not provided** if the network device does not support a local user store and requires all user/role information to be provided by an external authentication/authorization service. + - **NOTE:** Handling of password policies and LDAP attributes are not part of this role. +- O1\_network\_management: Allows read, write, and execute operations on the datastores. All operations on the /nacm objects are prohibited. +- O1\_network\_monitoring: Allows read operations on configuration data in the datastore, except for the /nacm objects. +- O1\_software\_management: Allows installation of new software including new software versions for a PNF. + +**REQ-NAC-FUN-4:** Users assigned to the O1\_nacm\_management group shall have read and write permission for the /nacm objects and attributes. Allowing changes to the NACM Global Enforcement Controls configuration is optional. + +**REQ-NAC-FUN-5:** Users assigned to the O1\_user\_management group shall have read and write permissions for the locally defined user store objects and attributes. + +**REQ-NAC-FUN-6:** Users assigned to the O1\_network\_management group shall have read, write, and execute permissions for the datastores. Users assigned to the O1\_network\_management group shall not have any permissions for the /nacm objects. + +**REQ-NAC-FUN-7:** Users assigned to the O1\_network\_monitoring group shall have read permissions for the datastores. Users assigned to the O1\_network\_monitoring group shall not have read permissions for the /nacm objects. + +**REQ-NAC-FUN-8:** Users assigned to the O1\_software\_management group shall have permissions to install new software on the PNF. + +**REQ-NAC-FUN-9:** NETCONF endpoints shall support external user-to-group mapping via LDAP with StartTLS. + +**REQ-NAC-FUN-10:** Management Service providers may allow the definition of users in the NACM object. + +**REQ-NAC-FUN-11:** NETCONF endpoints may support external user to group mapping via OAuth 2.0, RADIUS with EAP, and TACACS/TACACS+. + +### 5.2.3 O2 Interface + +#### 5.2.3.0 Introduction + +General Aspects and Principles of O2 Interface between the SMO and the O-Cloud are defined in [6]. + +#### 5.2.3.1 Requirements + +**REQ-SEC-O2-1:** O2 interface shall support confidentiality, integrity, and replay protection. + +**REQ-SEC-O2-2:** O2 interface shall support mutual authentication. + +**REQ-SEC-O2-3:** O2 interface shall support authorization using the principle of least privilege. + +#### 5.2.3.2 Security Controls + +**SEC-CTL-O2-1:** O2 interface shall support confidentiality and integrity protection using TLS, as specified in O-RAN Security Protocols Specifications [3] clause 4.2. + +**SEC-CTL-O2-2:** O2 interface, as shown in Figure 5.2.3.2-1, shall support mutual authentication using mTLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-O2-3:** O2 interface, as shown in Figure 5.2.3.2-1, shall support authorization using OAuth 2.0, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +![Diagram illustrating O2 interface security between SMO and O-Cloud. The SMO contains FOCOM and NFO components. The O-Cloud contains IMS and DMS components. Two green arrows represent mTLS with PKIX and OAuth connections: one between FOCOM and IMS, and another between NFO and DMS. Both connections are labeled 'O2'.](31f3e610f71626ee4cd9f1b71b17befd_img.jpg) + +``` + +graph LR + subgraph SMO + FOCOM + NFO + end + subgraph O_Cloud [O-Cloud] + IMS + DMS + end + FOCOM <--> |"mTLS with PKIX and OAuth +O2"| IMS + NFO <--> |"mTLS with PKIX and OAuth +O2"| DMS + +``` + +Diagram illustrating O2 interface security between SMO and O-Cloud. The SMO contains FOCOM and NFO components. The O-Cloud contains IMS and DMS components. Two green arrows represent mTLS with PKIX and OAuth connections: one between FOCOM and IMS, and another between NFO and DMS. Both connections are labeled 'O2'. + +Figure 5.2.3.2-1: O2 interface security + +### 5.2.4 E2 Interface + +#### 5.2.4.0 Introduction + +General Aspects and Principles of E2 Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, one or more O-DUs, and one or more O-eNBs are defined in [7]. + +#### 5.2.4.1 Requirements + +**REQ-SEC-E2-1:** E2 interface shall support confidentiality, integrity, replay protection and data origin authentication. + +#### 5.2.4.2 Security Controls + +**SEC-CTL-E2-1:** For the security protection at the IP layer on E2 interface, IPsec shall be supported as specified in O-RAN Security Protocols Specifications [3], clause 4.4. + +### 5.2.5 Open Fronthaul Interface + +#### 5.2.5.1 C-plane + +##### 5.2.5.1.1 Introduction + +The O-DU sends UL C-plane messages and DL C-plane messages to O-RU to trigger transmission and reception of RF signals. The DL C-plane message describing multiple symbols must arrive at O-RU within a certain time window for the O-RU to successfully receive DL I/Q data in U-plane messages from O-DU. Likewise, the UL C-plane message describing multiple symbols must arrive within a certain time window for the O-RU to successfully receive RF signal and send UL I/Q data in U-plane messages to O-DU. Any delay of these messages would cause the O-RU to drop/discard U-plane traffic from O-DU and the UE [31]. + +An adversary can inject its own DL C-plane or UL C-plane messages by spoofing the associated O-DU. As a result, it would block the O-RU from processing the corresponding U-Plane packets received from the O-DU and O-RU respectively, leading to temporary DoS and, limited cell performance on cells served by the O-RU [i.14]. Additionally, it may tamper with Downlink (DL) C-Plane messages to exploit possible vulnerabilities in the C-Plane protocol or C-Plane endpoint implementation. This can cause an active cell to become a sleeping cell, leading to cell unavailability and a temporary Denial-of-Service (DoS). + +Attackers may overwhelm a target system's network bandwidth or computing resources by flooding it with a massive volume of traffic known as volumetric Denial-of-Service (DoS) attack causing Bandwidth Exhaustion, Network Consumption, and Resource Consumption. + +An adversary can engage in passive monitoring to monitor the beamforming information for reconnaissance purposes. The flow indicator (eAxCID) in clear text allows an attacker to target a user at a specific location, potentially planning attacks based on the user's known location. + +The clear text nature of the C-Plane messages over the ethernet exposes the open-fronthaul to the threats described above. + +##### 5.2.5.1.2 Requirements + +**REQ-SEC-OFCP-1:** The C-Plane shall support authentication and authorization of O-DUs that exchange C-plane messages with O-RUs. + +**REQ-SEC-OFCP-2:** The O-DU shall be able to detect and defend against application level attacks across the C-Plane messages with O-RUs, due to misbehaviour or malicious intent. + +**REQ-SEC-OFCP-3:** Authenticity-, integrity and anti-replay protection should protect C-Plane data flows through the fronthaul network. + +**REQ-SEC-OFCP-4:** The C-Plane data should be confidentiality protected. + +##### 5.2.5.1.3 Security Controls + +###### 5.2.5.1.3.1 Authentication and Authorization of network elements supporting the C-Plane + +This clause addresses requirements REQ-SEC-OFCP-1 based on the use of IEEE 802.1X-2020 Port-based Network Access Control [12] for authentication and subsequent authorization of nodes that exchange C-Plane messages. + +Clause 5.2.5.5 provides requirements and security controls for the authentication and authorization of an O-DU and other network elements supporting the C-Plane within Open Fronthaul point-to-point LAN segments. + +###### 5.2.5.1.3.2 Securing the C-Plane data using MACsec + +This clause provides controls for requirements REQ-SEC-OFCP-3 and REQ-SEC-OFCP-4 based on the use of MACsec [79]. + +**SEC-CTL-OFCP-1:** The Open Fronthaul network elements should secure the C-Plane data by encapsulating it inside MACsec [79]. + +Clause 5.2.5.6 of this document provides the solutions for protection of Open Fronthaul messages and defines the security controls for encryption of the C-Plane data on the Open Fronthaul network segment. + +#### 5.2.5.2 U-plane + +##### 5.2.5.2.0 Introduction + +Open Fronthaul U-plane transports 3GPP Access Stratum (AS) Control Plane and User Plane messages between O-CU-CP and UE, and O-CU-UP and UE. 3GPP AS Control Plane and User Plane messages that are transported via the Open Fronthaul U-Plane (LLS-UP) are confidentiality and integrity protected by Packet Data Convergence Protocol (PDCP) [32][55]. The PDCP [32] security controls remain in place when the message traverses the Open Fronthaul U-Plane. + +However, there are certain U-Plane messages containing IQ samples, including PRACH, PUCCH, SSB, as well as O-RAN Application and eCPRI headers, that are transported over Open Fronthaul as encapsulated Ethernet packets without integrity and confidentiality protection. + +##### 5.2.5.2.1 Requirements + +**REQ-SEC-OFUP-1:** The OFH interface should support integrity and anti-replay protection to ensure that U-Plane data remains unaltered during transmission. + +**REQ-SEC-OFUP-2:** The OFH interface should support mutual authentication to ensure that both transmitting and receiving OFH network elements are authenticated before any U-Plane data is exchanged. + +**REQ-SEC-OFUP-3:** The OFH interface should support authorization to ensure that only authorized OFH network elements can exchange U-Plane data. + +**REQ-SEC-OFUP-4:** The OFH interface may support confidentiality to protect U-Plane data from unauthorized access during transmission. + +##### 5.2.5.2.2 Security Controls + +###### 5.2.5.2.2.1 Confidentiality protection for U-Plane data using MACsec + +Clause 5.2.5.6 of this document provides the solutions for protecting Open Fronthaul messages and defines the security controls for encrypting U-Plane data on the Open Fronthaul network segment using MACsec [79]. The security controls in clause 5.2.5.6 fulfil the requirements REQ-SEC-OFUP-1 and REQ-SEC-OFUP-4. + +**SEC-CTL-OFUP-1:** Void + +##### 5.2.5.2.2 Authentication and Authorization of network elements supporting the U-Plane + +Clause 5.2.5.5 outlines the requirements and security controls for the authentication and authorization of Open Fronthaul (OFH) network elements that support the U-Plane within point-to-point LAN segments using IEEE 802.1X-2020 Port-based Network Access Control [12]. The security requirements and controls in clause 5.2.5.5 fulfil the requirements REQ-SEC-OFUP-2 and REQ-SEC-OFUP-3. + +#### 5.2.5.3 S-plane + +##### 5.2.5.3.1 Introduction + +The Precision Time Protocol (PTP) is a protocol used to synchronize clocks within a PTP network. Within a PTP domain [27], the grandmaster clock is the source of time to which all other PTP clocks in the domain are synchronized. + +The IEEE 1588 standard [27] specifies the Best Master Clock Algorithm (BMCA) for electing the best clock from PTP Network and Local PTP Clock. The BMCA runs on PTP instances in the network continuously and is adjusting to changes in that network. PTP ANNOUNCE messages are used to build a timing distribution hierarchy with grandmaster at the top. There can be many grandmasters in PTP Network, but PTP Domain can have only one. The chosen grandmaster clock is responsible for providing timing to the PTP slave nodes. + +Following the selection of the new grandmaster, the grandmaster begins transmitting the current time within the SYNC message and FOLLOW\_UP messages if applicable. This allows the other clocks to synchronize their time to the grandmaster. + +S-Plane attacks include an attacker masquerading as a grandmaster or manipulating PTP to degrade synchronization. An attacker within the PTP network could impersonate the master clock's grandmaster's Identity value and propose himself as a grandmaster candidate by sending fake ANNOUNCE messages declaring him to be the best clock in the network. The malicious GM would provide intentionally inaccurate timing information that results in degradation in the accuracy of time synchronisation and may cause DoS to applications on all the RUs that rely on accurate time synchronisation, potentially bringing down the cell. + +Details are covered in [i.14], clause 7.4.1.2. + +The two most common deployment models for O-DU in O-RAN are: + +- O-DU at the cell site deployment model: the O-DU is collocated with the O-RU with a direct connection between the two (LLS-C1) through a cell site gateway router. +- O-DU at the Data Centre deployment model: the O-DU is at a Data Centre. The O-RU's at the cell site connect to the O-DU via a direct connection between O-RU and O-DU (LLS-C1) or intermediary Ethernet switches (LLS-C2 or LLS-C3). + +##### 5.2.5.3.2 Requirements + +**REQ-SEC-OFSP-1:** The S-Plane shall support authentication and authorization of PTP nodes that communicate with other PTP nodes within Configuration LLS-C1, Configuration LLS-C2, or Configuration LLS-C3. + +NOTE 1: This ensures least privilege access to the S-Plane where authenticated and authorized PTP nodes communicate over the Open Fronthaul network. + +NOTE 2: There is no specific requirement for authentication and authorization mechanism of S-plane PTP messages. + +**REQ-SEC-OFSP-2:** The S-Plane should provide a means to prevent spoofing of master clocks. + +**REQ-SEC-OFSP-3:** For the O-DU at the Data Centre deployment model the S-Plane should protect against MITM attacks that degrade the clock accuracy due to packet delay attacks or selective interception and removal attacks [28]. + +**REQ-SEC-OFSP-4:** The O-DU shall be able to detect and defend against application level attacks across the S-Plane interface, due to misbehaviour or malicious intent. + +**REQ-SEC-OFSP-5:** The S-Plane should support a security mechanism to authenticate the sender of the PTP ANNOUNCE messages. + +**REQ-SEC-OFSP-6:** The S-Plane should support a security mechanism for integrity protection of the PTP ANNOUNCE messages. + +**REQ-SEC-OFSP-7:** The S-Plane should support a security mechanism for replay protection of the PTP ANNOUNCE messages. + +**REQ-SEC-OFSP-8:** The S-Plane should support a security mechanism for confidentiality protection of the PTP messages. + +##### 5.2.5.3.3 Security Controls + +###### 5.2.5.3.3.1 Synchronization Architecture Redundancy + +This clause addresses requirement REQ-SEC-OFSP-3 by providing an architectural recommendation to S-plane security based on redundancy in the Open Fronthaul Synchronization architecture. + +The following architectural recommendations for security controls build S-Plane redundancy into to the Open Fronthaul for increased robustness against security breaches. + +**SEC-CTL-OFSP-1:** The Open Fronthaul Synchronization architecture should support simultaneous Grandmasters. + +**SEC-CTL-OFSP-2:** The Open Fronthaul Synchronization architecture should support the assignment of GMs to physically separated PTP ports. Multiple masters could be connected to offer topology resilience. + +O-RAN Synchronization Architecture and Solution Specification [30], clause 8.2.3 Timing/Synchronization Redundancy & Resiliency provides additional details on redundancy for the Open Fronthaul Synchronization architecture. + +###### 5.2.5.3.3.2 Authentication and Authorization of PTP nodes + +This clause addresses requirements REQ-SEC-OFSP-1 and REQ-SEC-OFSP-2 based on the use of IEEE 802.1X-2020 Port-based Network Access Control [12] for authentication and subsequent authorization of PTP nodes. + +Clause 5.2.5.5 provides requirements and security controls for the authentication and authorization of S-Plane PTP nodes within Open Fronthaul point-to-point LAN segments. + +###### 5.2.5.3.3.3 Securing PTP ANNOUNCE Messages using IEEE 1588 Authentication TLV + +This clause provides security controls for REQ-SEC-OFSP-5 , REQ-SEC-OFSP-6, and REQ-SEC-OFSP-7 using IEEE 1588-2019 ([27]) AUTHENTICATION TLV (clause 16.14) to provide source authentication, message integrity, and replay attack protection for PTP ANNOUNCE messages within a PTP domain. + +**SEC-CTL-OFSP-3:** The Open Fronthaul Synchronization architecture may support IEEE 1588-2019 [27] Authentication TLV for securing PTP ANNOUNCE messages. + +###### 5.2.5.3.3.4 MACsec for S-Plane + +This clause introduces MACsec as a mechanism to provide source authentication, message integrity, and replay attack protection for S-plane. + +**SEC-CTL-OFSP-4:** The Open Fronthaul Synchronization architecture may support MACsec for securing PTP messages. + +#### 5.2.5.4 M-plane + +##### 5.2.5.4.1 Requirements + +The security requirements for M-Plane are defined in [14]. + +##### 5.2.5.4.2 Security Controls + +The security controls for M-plane are defined in [14]. + +#### 5.2.5.5 Open Fronthaul Point-to-Point LAN Segment + +##### 5.2.5.5.1 Introduction + +The Open Fronthaul Ethernet L1 physical interface comprises one or more coaxial cables, twisted pairs, or optical fibers. These are also known as point-to-point LAN segments [12]. Each end of the Open Fronthaul point-to-point LAN segment comprises a physical connection (colloquially known as an Ethernet Port) to physical O-RAN network elements, as described in [13] and [14]. + +EXAMPLE: Physical O-RAN network elements includes O-DU, O-RU. + +An Open Fronthaul network element is an entity in a point-to-point LAN segment. Xhaul Transport Network Elements that share a point-to-point LAN segment with Open Fronthaul network elements are also Open Fronthaul network elements. Examples of O-RAN Alliance defined Open Fronthaul network elements include, but are not limited to, O-DU, O-RU, switches, FHM, FHGW, TNE and PRTC-T/GM, see [13],[14],[15] and [26]. + +##### 5.2.5.5.2 Requirements + +**REQ-SEC-OFHPLS-1:** The Open Fronthaul shall provide a means to authenticate and authorize point-to-point LAN segments between Open Fronthaul network elements. + +**REQ-SEC-OFHPLS-2:** The Open Fronthaul shall provide a means to detect and report when an authorized point-to-point LAN segment is made or broken. + +**REQ-SEC-OFHPLS-3:** The Open Fronthaul shall provide a means to block access to unused Ethernet ports in an Open Fronthaul network element. + +Open Fronthaul implementations may support IEEE 802.1X-2020 [12] to satisfy the requirements listed above. Implementations that support optional 802.1X shall provide the security controls as specified in clause 5.2.5.5.3. + +##### 5.2.5.5.3 Security Controls + +###### 5.2.5.5.3.1 Solution #1: Authentication and Authorization based on 802.1X Port based Network Access Control + +IEEE 802.1X-2020 [12] is optional to support. + +IEEE 802.1X-2020 [12] Port-based Network Access Control provides the means to control network access in point-to-point LAN segments within the Open Fronthaul network. Port-based network access control in the O-RAN Alliance Open Fronthaul comprises supplicant, authenticator, and authentication server entities described in IEEE 802.1X-2020 [12] and as further described in this clause. All other entities and functionality described in IEEE 802.1X [12] are out of scope of this O-RAN Alliance specification and are determined by vendor implementation in agreement with operator-specific requirements. + +**SEC-CTL-OFHPLS-1:** Operator implementation of IEEE 802.1X-2020 [12] for Open Fronthaul port-based network access control is optional to use for each point-to-point LAN segment. + +###### Supplicants in the Open Fronthaul Network + +**SEC-CTL-OFHPLS-2:** Open Fronthaul network elements shall support IEEE 802.1X-2020 [12] supplicant functionality for each port connection in the Open Fronthaul network element. + +###### Authenticators in the Open Fronthaul Network + +In IEEE 802.1X-2020 [12] a supplicant mutually authenticates with an authenticator. + +**SEC-CTL-OFHPLS-3:** Any Open Fronthaul network element may be an authenticator in the Open Fronthaul network. + +**SEC-CTL-OFHPLS-4:** An authenticator in an Open Fronthaul network shall perform port-based network access control on each point-to-point LAN segment as defined in IEEE 802.1X-2020 [12]. + +**SEC-CTL-OFHPLS-5:** Port-based network access control between a supplicant and authenticator in an Open Fronthaul network shall use EAP-TLS authentication as defined in IEEE 802.1X-2020 [12]. + +###### O-DU as an Authenticator + +Configuration LLS-C1 [13] and Cascade Mode in the Shared Cell Concept [12] are cases where an O-DU and O-RU are Open Fronthaul network elements in a point-to-point LAN segment. + +**SEC-CTL-OFHPLS-6:** In the case of Configuration LLS-C1, the O-DU shall support the authenticator functionality as defined in IEEE 802.1X-2020 [12]. + +###### Authenticator interface to an Authentication Server in the Open Fronthaul Network + +IEEE 802.1X describes an EAP-TLS exchange which includes an interface between an authenticator and authentication server [12]. + +**SEC-CTL-OFHPLS-7:** The interface between an authenticator and authentication server shall support IETF RADIUS standards, IETF RFC 2865 [22], IETF RFC 2866 [23], IETF RFC 3579 [24], and successor standards. + +**SEC-CTL-OFHPLS-8:** The interface between an authenticator and authentication server should support IETF Diameter standards, IETF RFC 4072 [25] and successor standards. + +NOTE : Mechanisms to secure the interface between the authenticator and authentication server are out of scope of the O-RAN Alliance. + +###### 5.2.5.5.3.2 Authentication and authorization procedure for 802.1X Port based Network Access Control + +###### General requirements + +Only those Open Fronthaul network elements acting as a supplicant that have mutually authenticated with an authenticator are authorized to participate in the Open Fronthaul network. If an authenticator port is to be activated in the Open Fronthaul, then the authenticator places the port into an unauthorized state that allows EAP over LAN (EAPOL) packets for EAP authentication and blocks all other traffic. If the mutual authentication has been successful and the operator authorizes operation for the network element port, then the port is switched to the authorized state whereby non-EAPOL packets can be sent and received. + +**SEC-CTL-OFHPLS-9:** Open Fronthaul network elements acting as an authenticator shall place each of its unauthorized ports into a state that allows EAPOL traffic and block all other Ethernet traffic. + +**SEC-CTL-OFHPLS-10:** Open Fronthaul network elements acting as an authenticator should be able to implement authorization policies that apply to its authorized ports. + +NOTE: Authorization policies may include tagging authorized traffic with a particular VLAN-ID as it egresses the Open Fronthaul network element and/or enforcing access control policies that restrict the type of traffic able to be forwarded by the Open Fronthaul network element. + +###### Manufacturer Install Certificates + +This clause applies to the Extensible Authentication Protocol as defined in IEEE 802.1X [12]. where such an approach is used. A supplicant implements an EAP method according to its supported credentials. Prior to a supplicant enrolling in + +an operator's PKI, a manufacturer installed certificate shall be used together with an EAP-TLS dialogue to enable certificate-based mutual authentication to be performed between an authenticator and a supplicant. + +**SEC-CTL-OFHPLS-11:** The O-RU shall have installed a Manufacturer Installed X.509 Certificate. + +###### Security Procedure + +The following procedure describes the authentication and authorization, based on IEEE 802.1X Port based Network Access Control, of point-to-point LAN segments between a supplicant and another Open Fronthaul network element acting as an authenticator. + +**SEC-CTL-OFHPLS-12:** The normal operation procedure defined in IEEE 802.1X [12] shown in Figure 5.2.5.5.3-1 shall be performed to authenticate and authorize an O-RU within an Open Fronthaul network. + +``` +@startuml +!pragma teoz true +skinparam defaultTextAlignment center + +participant "Authentication\nServer" as AAA +participant "IEEE 802.1x\nAuthenticator" as AUT +participant "IEEE 802.1x \nSupplicant" as SUP + +note over AAA + Manufacturer Trust + Root Installed +end note + +¬e over SUP + Manufacturer Installed + X.509 Certificate +end note + +¬e over AUT + Port in unauthorized + state - blocks all + traffic other than + EAPoL traffic +end note + +group Initial limited-access when authenticated using manufacturer certificate + SUP->>AUT: EAPoL Start + AUT->>SUP: EAP-Request/Identity + SUP->>AUT: EAP-Response/Identity (from Manufacturer Installed X.509 Certificate + Subject DN) + + AUT->>AAA: RADIUS-Access-Request or Diameter-EAP-Request (EAP-Response) + AAA->>AUT: RADIUS-Access-Challenge or Diameter-EAP-Answer (EAP-Request) + AUT->>SUP: EAPoL (EAP-Request) + note over AAA, SUP + EAP Dialogue Continues using Manufacturer Installed X.509 Certificate + end note + AAA->>AAA: Select Security Policy \nfor Manufacturer Installed X.509 Certificate + AAA->>AUT: RADIUS-Access-Accept or Diameter-EAP-Answer (EAP-Success) \nIncluding + security policy, e.g., Provisioning/Enrollment VLAN + AUT->>SUP: EAP-Success + + AUT->>AUT: Set port to authorized state.\nAssign port to provided security policy, + \ne.g., Provisioning/Enrollment VLAN +end + +group Enrollment into operator PKI + note over AUT, SUP +``` + +``` + +Certificate Enrollment Completes & Provision of Operator X.509 Certificate +end note + +SUP->SUP: Install\nOperator X.509\nCertificate +end + +group Subsequent full operational access when authenticated using operator installed +certificate + + note over SUP + re-start of Supplicant + triggers interface + re-initialization + end note + + note over AUT + Interface re-initialization: + resets port to unauthorized + state - blocks all traffic + other than EAPoL traffic + end note + + SUP->AUT: EAPoL Start + AUT->SUP: EAP-Request/Identity + SUP->AUT: EAP-Response/Identity (from Operator X.509 Certificate Subject DN) + + AUT->AAA: RADIUS-Access-Request or Diameter-EAP-Request (EAP-Response) + AAA->AUT: RADIUS-Access-Challenge or Diameter-EAP-Answer (EAP-Request) + AUT->SUP: EAPoL (EAP-Request) + note over AAA, SUP + EAP Dialogue Continues using Operator Installed X.509 Certificate + end note + AAA->AAA: Select Security Policy\nfor Operator Installed X.509 Cert + AAA->AUT: RADIUS-Access-Accept or Diameter-EAP-Answer (EAP-Success) \nIncluding +security policy, e.g., Operational VLAN + AUT->SUP: EAP-Success + + AUT->AUT: Set port to authorized state.\nAssign port to provided security policy, +\n e.g., Operational VLAN + + note over SUP + Normal Supplicant + start up continues + end note + +end + +@enduml + +``` + +![Sequence diagram showing the normal operation of 802.1X port-based authentication in the O-RAN Fronthaul architecture. The diagram involves three main entities: Authentication Server, IEEE 802.1X Authenticator, and IEEE 802.1X Supplicant. The process is divided into three main phases: Initial limited-access when authenticated using manufacturer certificate, Enrollment into operator PKI, and Subsequent full operational access when authenticated using operator installed certificate. The diagram shows the flow of EAPoL messages, RADIUS/Diameter messages, and the state transitions of the port and the supplicant.](e5ad9041ce751c5966017093c1de73f0_img.jpg) + +**Initial limited-access when authenticated using manufacturer certificate** + +- Authentication Server: Manufacturer Trust Root Installed +- IEEE 802.1X Authenticator: Port in unauthorized state - blocks all traffic other than EAPoL traffic +- IEEE 802.1X Supplicant: Manufacturer Installed X.509 Certificate + +**Enrollment into operator PKI** + +- IEEE 802.1X Supplicant: Install Operator X.509 Certificate + +**Subsequent full operational access when authenticated using operator installed certificate** + +- IEEE 802.1X Authenticator: Interface re-initialization: resets port to unauthorized state - blocks all traffic other than EAPoL traffic +- IEEE 802.1X Supplicant: re-start of Supplicant triggers interface re-initialization +- IEEE 802.1X Supplicant: Normal Supplicant start up continues + +**Sequence of Events:** + +- EAPoL Start (Authenticator to Supplicant) +- EAP-Request/Identity (Authenticator to Supplicant) +- EAP-Response/Identity (from Manufacturer Installed X.509 Certificate Subject DN) (Supplicant to Authenticator) +- RADIUS-Access-Request or Diameter-EAP-Request (EAP-Response) (Authenticator to Server) +- RADIUS-Access-Challenge or Diameter-EAP-Answer (EAP-Request) (Server to Authenticator) +- EAPoL (EAP-Request) (Authenticator to Supplicant) +- EAP Dialogue Continues using Manufacturer Installed X.509 Certificate +- Select Security Policy for Manufacturer Installed X.509 Certificate (Authenticator to Server) +- RADIUS-Access-Accept or Diameter-EAP-Answer (EAP-Success) Including security policy, e.g., Provisioning/Enrollment VLAN (Server to Authenticator) +- EAP-Success (Authenticator to Supplicant) +- Set port to authorized state. Assign port to provided security policy, e.g., Provisioning/Enrollment VLAN (Authenticator) +- Certificate Enrollment Completes & Provision of Operator X.509 Certificate (Supplicant) +- Install Operator X.509 Certificate (Supplicant) +- Interface re-initialization: resets port to unauthorized state - blocks all traffic other than EAPoL traffic (Authenticator) +- re-start of Supplicant triggers interface re-initialization (Supplicant) +- EAPoL Start (Authenticator to Supplicant) +- EAP-Request/Identity (Authenticator to Supplicant) +- EAP-Response/Identity (from Operator X.509 Certificate Subject DN) (Supplicant to Authenticator) +- RADIUS-Access-Request or Diameter-EAP-Request (EAP-Response) (Authenticator to Server) +- RADIUS-Access-Challenge or Diameter-EAP-Answer (EAP-Request) (Server to Authenticator) +- EAPoL (EAP-Request) (Authenticator to Supplicant) +- EAP Dialogue Continues using Operator Installed X.509 Certificate +- Select Security Policy for Operator Installed X.509 Cert (Authenticator to Server) +- RADIUS-Access-Accept or Diameter-EAP-Answer (EAP-Success) Including security policy, e.g., Operational VLAN (Server to Authenticator) +- EAP-Success (Authenticator to Supplicant) +- Set port to authorized state. Assign port to provided security policy, e.g., Operational VLAN (Authenticator) +- Normal Supplicant start up continues (Supplicant) + +Sequence diagram showing the normal operation of 802.1X port-based authentication in the O-RAN Fronthaul architecture. The diagram involves three main entities: Authentication Server, IEEE 802.1X Authenticator, and IEEE 802.1X Supplicant. The process is divided into three main phases: Initial limited-access when authenticated using manufacturer certificate, Enrollment into operator PKI, and Subsequent full operational access when authenticated using operator installed certificate. The diagram shows the flow of EAPoL messages, RADIUS/Diameter messages, and the state transitions of the port and the supplicant. + +**Figure 5.2.5.5.3.2-1: Normal Operation of 802.1X Port Based Authentication in the O-RAN Fronthaul architecture** + +The authentication and authorization procedure may fail at any moment, for example because of no response from the supplicant after a network request. In that case, the operation procedure as specified in Figure 5.2.5.5.2-1 will be terminated as specified in IEEE 802.1X-2020 [12]. + +**O-RAN.WG11.SecReqCtlSpecs.0-R004-v11.00** + +Image: O-RAN Alliance Logo + +**O-RAN** +ALLIANCE + +### 5.2.5.6 Protecting Open Fronthaul messages using MACsec + +#### 5.2.5.6.1 Introduction + +MACsec defined in the standard IEEE 802.1AE -2018[79] is a Layer 2 protocol that provides data confidentiality, frame data integrity, and authenticity of data origin including replay protection for all types of traffic on Ethernet links. + +MACsec can be configured in an End-to-End mode or Hop-by-Hop mode. Hop-by-Hop mode requires the intermediate nodes to support MACsec. End-to-End mode does not require the intermediate nodes to support MACsec. MACsec configuration can be applied per VLAN or at the base interface level. + +The following clause describes the supported encryption modes for establishing MACsec. + +1. MACsec using EDE-CC +2. WAN mode MACsec +3. LAN mode MACsec + +The Open Fronthaul network element can use one of the encryption modes based on the specific Open Fronthaul traffic that requires protection. + +### 5.2.5.6.2 MACsec using EDE-CC + +#### 5.2.5.6.2.1 Introduction + +In this mode, MACsec uses EDE-CC, controlled port, uncontrolled port as functional blocks from IEEE 802.1AE-2018 [79]. This solution applies to scenarios where MACsec is applied based on VLAN tags and configured at the VLAN interface. + +This mode allows 802.1Q VLAN tags to be encrypted inside the MACsec header and also sent in clear text, outside the MACsec header. The inner VLAN tag is protected by MACsec while the outer VLAN tag is used for VLAN based switching in a network where some transport network elements may not be MACsec capable. This solution enables MACsec to be configured in an end-to-end tunnel mode such that the intermediate nodes may be MACsec-unaware. + +To prevent intermediary nodes from consuming EAPoL packets, it is recommended to configure the group destination address as specified in IEEE 802.1AE-2018 [79], Table 15.1. + +Figure 5.2.5.6.2-1 depicts the scenario where the O-RU and O-DU are connected via a switched fronthaul network and MACsec is enabled at O-DU and O-RU in an End-to-End tunnel mode. The TNE and intermediary switches may or may not support MACsec capabilities. + +Image: Figure 5.2.5.6.2-1: End-to-End MACsec solution for fronthaul security protection + +**Figure 5.2.5.6.2-1: End-to-End MACsec solution for fronthaul security protection** + + + +--- + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification +51 + +The O-DU functional block transmits the Open Fronthaul message that needs encryption to the controlled port, which passes through an EDE functional block. This EDE block secures the Open Fronthaul message using MACsec. The messages are filtered based on their EtherType. The EDE-CC, a variant of EDE, adds a cleartext VLAN header before the MACsec header, which includes VLAN and VLAN PCP bits, that are used for VLAN-based switching and identifying QoS profiles in the MACsec-unaware Fronthaul TNE connected to the O-DU. At the receiving endpoint, the O-RU validates the encrypted traffic received at the EDE using MACsec. Upon successful validation, it forwards the traffic via the controlled port to the O-RU functional block. Communication from the O-RU to the O-DU follows a similar process. + +The O-DU functional block transmits the S-Plane messages that do not require encryption to the uncontrolled port. The S-Plane message has a specific PTP EtherType for the G.8275.1 profile. The demultiplexing operation selectively filters out PTP traffic based on its EtherType and forwards it to the uncontrolled port. As a result, PTP messages exit the hardware port unprotected by MACsec. When receiving, the O-RU maps PTP messages to the uncontrolled port based on the EtherType. Through the uncontrolled port, PTP messages are directed to the 1588 layer in the O-RU functional block. + +Depending on the chosen network topology, the MACsec tunnel endpoint can be a TNE, and the functionalities of controlled, uncontrolled ports, and EDE can apply to it. Communication between the selected MACsec tunnel endpoints would occur in a similar manner. + +###### 5.2.5.6.2.2 Security Controls + +This clause specifies the security controls for configuring MACsec using EDE-CC. The Open Fronthaul network elements include the O-DU, O-RU and TNE. + +**SEC-CTL-OFHMECC-1:** The Open Fronthaul network elements may support the functional blocks of controlled port, uncontrolled port, and Ethernet Data Encryption (EDE), as defined in the standard IEEE 802.1AE -2018 [79] clauses 5.2, 5.3 and 15.6. + +**SEC-CTL-OFHMECC-2:** The Open Fronthaul network elements may demultiplex PTP messages identified by EtherType for G.8275.1 to the uncontrolled port that remain unprotected by MACsec. + +**SEC-CTL-OFHMECC-3:** The Open Fronthaul network elements may forward the data that need to be encrypted to the controlled port. The controlled port then sends the data to the EDE functional block that is secured by MACsec. + +**SEC-CTL-OFHMECC-4:** The Open Fronthaul network elements may support the EDE-CC functionality that allows utilization of the frame's VLAN tag for service selection and conveyance of Priority Code Point (PCP) and drop-eligible (DEI) information. + +**SEC-CTL-OFHMECC-5:** If an Open Fronthaul network element supports the EDE-CC functionality, it shall support the cipher suites, as specified in O-RAN Security Protocols Specifications [3], clause 4.9. + +##### 5.2.5.6.3 WAN mode MACsec + +###### 5.2.5.6.3.1 Introduction + +This mode allows the 802.1Q VLAN tag to be unencrypted and sent in clear text, outside the MACsec header. This solution applies to scenarios where MACsec is applied based on VLAN tag and configured at the VLAN interface. This solution enables the intermediary switches that are MACsec-unaware to switch the packets based on the VLAN tag. + +To prevent MACsec capable intermediary nodes from consuming EAPoL packets, it is recommended to configure the group destination address to allow the intermediary nodes to tunnel the packets like data packets. + +###### 5.2.5.6.3.2 Security Controls + +This clause specifies the security controls for configuring MACsec using VLAN in the clear. The Open Fronthaul network elements include the O-DU, O-RU and TNE. + +**SEC-CTL-OFHWMM-1:** The Open Fronthaul network elements may support a MACsec solution allowing the VLAN header to travel in the clear. + +**SEC-CTL-OFHWMM-2:** If an Open Fronthaul network element supports a MACsec solution allowing the VLAN header to travel in the clear, it shall support the cipher suites, as specified in O-RAN Security Protocols Specifications [3], clause 4.9. + +##### 5.2.5.6.4 LAN mode MACsec + +###### 5.2.5.6.4.1 Introduction + +This solution requires that the entire Ethernet frame after the MAC address should be encrypted. The Secure TAG of MACsec encompasses both VLAN-tagged and non-VLAN-tagged frames, securing all traffic that travels through the interface of an Open Fronthaul network element. + +It may be possible to configure additional policies to bypass MACsec protection based on EtherType, VLAN ID, and destination address. When enabled, this capability allows certain types of Open Fronthaul traffic, such as S-Plane, to remain unencrypted and bypass MACsec protection. + +###### 5.2.5.6.4.2 Security Controls + +This clause specifies the security controls for configuring MACsec to protect the entire Ethernet frame after the MAC address. The Open Fronthaul network elements include the O-DU, O-RU and TNE. + +**SEC-CTL-OFHLM-1:** The Open Fronthaul network elements may support securing of all Open Fronthaul traffic using MACsec. + +**SEC-CTL-OFHLM-2:** The Open Fronthaul network elements may support the configuration of policies to allow certain type of Open Fronthaul traffic to be sent in clear text. + +**SEC-CTL-OFHLM-3:** If an Open Fronthaul network element supports securing of all Open Fronthaul traffic using MACsec, the Open Fronthaul network element shall support the cipher suites, as specified in O-RAN Security Protocols Specifications [3], clause 4.9. + +### 5.2.6 R1 Interface + +#### 5.2.6.0 Introduction + +R1 is the interface between rApps and Non-RT RIC Framework via which R1 Services can be produced and consumed. See R1 specification [39]. + +#### 5.2.6.1 Requirements + +**REQ-SEC-R1-1:** R1 interface shall support confidentiality, integrity, and replay protection. + +**REQ-SEC-R1-2:** R1 interface shall support mutual authentication. + +**REQ-SEC-R1-3:** R1 interface shall support authorization with the principle of least privilege. + +#### 5.2.6.2 Security Controls + +![Diagram showing the R1 interface between the Non-RT RIC Framework and the rApp. A green double-headed arrow labeled 'mTLS' is positioned above a black line labeled 'R1' connecting the two boxes.](bdc2cf9e49f32dbe0f80aebff483b7d3_img.jpg) + +``` + +graph LR + A[Non-RT RIC Framework] <-->|mTLS| B[rApp] + A ---|R1| B + +``` + +Diagram showing the R1 interface between the Non-RT RIC Framework and the rApp. A green double-headed arrow labeled 'mTLS' is positioned above a black line labeled 'R1' connecting the two boxes. + +**Figure 5.2.6.2-1: mTLS on R1 interface** + +**SEC-CTL-R1-1:** For the security protection at the transport layer on R1 interface, TLS shall be supported as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-R1-2:** For the mutual authentication of the Non-RT RIC Framework and rApps, the R1 interface shall support mTLS with PKI using X.509v3 certificates, as shown in Figure 5.2.6.2-1 and specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**SEC-CTL-R1-3:** The R1 interface shall support authorization using OAuth 2.0, as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +### 5.2.7 Y1 Interface + +#### 5.2.7.1 Introduction + +The Near-RT RIC provides RAN analytics information services via Y1 service interface. These services can be consumed by Y1 consumers by subscribing to or requesting the RAN analytics information via the Y1 service interface. Y1 consumers may be Application Functions (AFs). The Near-RT RIC serves as Y1 provider. + +#### 5.2.7.2 Requirements + +**REQ-SEC-Y1-1:** The Y1 provider shall provide mechanisms to authenticate the Y1 consumer and allow for the Y1 consumer to authenticate the Y1 provider (mutual authentication). + +**REQ-SEC-Y1-2:** The Y1 provider shall authorize the Y1 consumer before allowing access to any service over the Y1 interface. + +**REQ-SEC-Y1-3:** The Y1 interface shall provide mechanisms to provide confidentiality and integrity protection for all data exchanged. + +**REQ-SEC-Y1-4:** The Y1 interface shall provide replay-protection for all data exchanged. + +**REQ-SEC-Y1-5:** The Y1 interface shall enforce the result of the authentication for the duration of communications. + +**REQ-SEC-Y1-6:** The Near-RT RIC shall hide its topology from the Y1 consumers accessing the Y1 interface. + +#### 5.2.7.3 Security Controls + +##### 5.2.7.3.1 Y1 interface protocol structure solution 1 + +The Y1 interface protocol structure solution 1 is defined in the O-RAN ALLIANCE TS: "Y1 interface: General Aspects and Principles" [66], clause 7.2. + +**SEC-CTL-Y1-1:** The Y1 interface protocol structure solution 1 shall support mutual TLS (mTLS) authentication via X.509v3 certificates, as specified in O-RAN Security Protocols Specifications [3], clause 4.2. + +**NOTE 1:** In mTLS, both the client (the Y1 consumer) and the server (the Y1 provider) require a certificate, and both sides authenticate each other using their public/private key pair. + +**SEC-CTL-Y1-2:** The Y1 interface protocol structure solution 1 shall support the OAuth 2.0 authorization framework as specified in O-RAN Security Protocols Specifications [3], clause 4.7. + +The roles defined in OAuth 2.0 shall be assigned as follows: + +- Resource owner / Resource server (producer): Y1 provider +- Client (consumer): Y1 consumer + +**SEC-CTL-Y1-3:** The Y1 interface protocol structure solution 1 shall support TLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2, to provide data confidentiality, integrity, and replay-protection. + +## 5.3 Transversal requirements + +### 5.3.1 Software Bill of Materials + +Void + +#### 5.3.1.1 Requirements + +Void + +### 5.3.2 Common Application Lifecycle Management + +#### 5.3.2.1 Package Protection + +##### 5.3.2.1.1 Requirements + +**REQ-SEC-ALM-FUN2-1:** Void + +**REQ-SEC-ALM-FUN3-1:** Void + +**REQ-SEC-ALM-PKG-1:** The application package shall be certified by the Solution Provider. + +**EXAMPLE:** Software testing suites for certification include vulnerability scanning, static and dynamic testing, and penetration testing. Refer to Annex C clause C.2.1 for additional information. + +**REQ-SEC-ALM-PKG-2:** The application package shall be protected by the Solution Provider prior to its delivery to the Service Provider in terms of authenticity and integrity. + +**REQ-SEC-ALM-PKG-3:** The application package shall include the signing certificate and signature(s) of Solution Provider. + +**REQ-SEC-ALM-PKG-4:** Each application artifact shall be digitally signed individually by the Solution Provider. + +**REQ-SEC-ALM-PKG-5:** SMO shall verify all application artifacts authenticity and integrity during onboarding. + +**REQ-SEC-ALM-PKG-6:** SMO shall verify application package authenticity and integrity during onboarding. + +**REQ-SEC-ALM-PKG-7A:** The application package shall be tested by the Service Provider for known security vulnerabilities. All discovered vulnerabilities shall be reported to the Solution Provider. + +**REQ-SEC-ALM-PKG-7B:** The Solution Provider shall have a vulnerability management process in place allowing the Service Provider to report discovered vulnerabilities. + +**REQ-SEC-ALM-PKG-7C:** Vulnerabilities discovered in application packages during testing by Service Provider shall be remediated by the Solution Provider. + +**REQ-SEC-ALM-PKG-8:** Application packages or application artifacts should be digitally signed by Service Provider before it is stored in any Service Provider repository [16]. + +**REQ-SEC-ALM-PKG-9:** Signature(s) shall be renewed before the certificate reaches the end of its validity period. + +**REQ-SEC-ALM-PKG-10:** Application packages and application artifacts stored in any Service Provider repository [16] shall be protected in terms of integrity and confidentiality. + +**REQ-SEC-ALM-PKG-11:** Application packages stored in any Service Provider repository [16] shall be accessible to only authorized entities and over networks that enforce authentication, integrity, and confidentiality. + +**REQ-SEC-ALM-PKG-12:** Every Service Provider repository [16] shall contain only application packages and application artifacts with verifiable signature(s). + +NOTE 1: Application packages and application artifacts are always signed by Solution Provider (see REQ-SEC-ALM-PKG-2, REQ-SEC-ALM-PKG-4). Additionally, Service Provider has option to sign application packages and application artifacts using its own certificates (see REQ-SEC-ALM-PKG-8). If Service Provider signs as well, there are 2 signatures present. + +**REQ-SEC-ALM-PKG-13:** Sensitive information used during the lifecycle of the application shall be protected in terms of confidentiality at rest and in transit, see [46], [47] and [48]. + +**REQ-SEC-ALM-PKG-14:** SMO shall contain a pre-installed root certificate of trusted CA (trusted by the Service Provider) before the onboarding of the application package for verifying its authenticity and integrity. Root certificate shall be delivered via a trusted channel separately from an application package [42]. + +**REQ-SEC-ALM-PKG-15:** Application packages shall have a Change Log. All the changes in the application package shall be versioned, tracked, and inventoried in the Change Log [43]. + +NOTE 3: Change log can also be provided separately as an external artifact. + +**REQ-SEC-ALM-PKG-16:** During deployment, SMO or O-Cloud shall verify all application artifacts authenticity and integrity. + +##### 5.3.2.1.2 Security Controls + +**SEC-CTL-ALM-PKG-1:** During onboarding, SMO shall verify the signature(s) of the application package as well as the signature(s) of application artifacts. + +To verify the signature of the application package, one of the two following options shall be followed as defined in ETSI GS NFV-SOL004 [42], clause 5: + +- Option 1: The application package contains a Digest (a.k.a. hash) for each of the artifacts in the manifest of the application package. The manifest is signed with the Solution Provider private key. +- Option 2: The complete application package is signed with the Solution Provider private key. + +The signature verification process comprises the following steps: + +**Responsible: Solution Provider, Service Provider** + +- (1) Application package shall be delivered to the Service Provider together with a signing Solution Provider certificate and signature. +- (2) The root CA certificate shall be pre-installed within the SMO for the validation of the Solution Provider signing certificate authenticity. +- (3) Upon reception of the signed application package from Solution Provider by the Service Provider: + - a. In Option 1, SMO shall verify the signature of the manifest. SMO shall recalculate the digests of all artifacts and all digests shall be verified against the ones in the manifest. + - b. In Option 2, SMO shall verify the application package signature. +- (4) SMO shall verify the Solution Provider digital signature of every application artifact. +- (5) SMO may sign onboarded application package before storing it in any Service Provider repository. +- (6) SMO may sign onboarded application artifacts before storing them in any Service Provider repository. + +**SEC-CTL-ALM-PKG-1A:** Algorithms, key sizes, and standards to be used for digital signing and verification of digital signature shall follow the "O-RAN Security Protocols Specifications" [3], clause 5. + +**SEC-CTL-ALM-PKG-1B:** During deployment, SMO or O-Cloud shall verify the signatures of all the onboarded application artifacts necessary for deployment, both the Service Provider signature created by Service Provider, if applicable by the Service Provider policy, and the Solution Provider signature. + +**SEC-CTL-ALM-PKG-2:** Sensitive artifacts shall be encrypted for confidentiality protection. + +**SEC-CTL-ALM-PKG-2A:** Algorithms, key sizes, and standards to be used for encryption/decryption shall follow the O-RAN Security Protocols Specifications [3], clause 5. + +**SEC-CTL-ALM-PKG-3:** Applications supported in the ETSI profile [80] shall be compliant with ETSI NFV specifications, ETSI GS NFV-SOL004 [42] clause 5, and ETSI GS NFV-SEC 021 [41] clauses 5 and 6, for package formats and signing/verification procedures. + +NOTE: The packaging format for container-based applications in the Kubernetes profile is being defined at the time of publishing this specification. + +**SEC-CTL-ALM-PKG-4:** Encryption shall be used to secure cryptographic keys used by the cryptographic operations. + +EXAMPLE: Cryptographic operations include signature generation/verification, encryption/decryption, and hashing. + +#### 5.3.2.2 Secure Update + +##### 5.3.2.2.1 Requirements + +**REQ-SEC-ALM-SU-1:** Application updates shall follow the same security requirements as Application packages. + +**REQ-SEC-ALM-SU-2:** Applications should be updated with their latest security updates. + +**REQ-SEC-ALM-SU-3:** Applications should be protected from downgrade attacks to older, possibly vulnerable, software versions. + +**REQ-SEC-ALM-SU-4:** Security updates for Application vulnerabilities should be available in a timely manner after discovery of known vulnerability or vulnerabilities for an Application. + +#### 5.3.2.3 Security Descriptor + +##### 5.3.2.3.1 Requirements + +**REQ-SEC-LCM-SD-1:** The Application descriptor shall support a description of the security group rules. Those rules shall be associated to the relevant Application interfaces. + +EXAMPLE: Security group rules include permissions, access control and filtering rules + +**REQ-SEC-LCM-SD-2:** The Application descriptor shall support a description of the Service Availability Level (SAL) requirements for virtual resources on the underlying O-Cloud platform. + +**REQ-SEC-LCM-SD-3:** The O-Cloud platform shall use the security group rules in the application descriptor for controlling the traffic direction, who can access the Application, what actions they can perform, and what level of access they have. + +**REQ-SEC-LCM-SD-4:** The SMO shall use the Service Availability Level (SAL) in the Application descriptor for governing the status (availability, deployment, and operation) of Applications and reacting whenever a SAL requirement is being breached. + +**REQ-SEC-LCM-SD-5:** The NFO shall support the ability to compare the Application's current owned resource consumption with the defined resource quotas from the Application descriptor. + +**REQ-SEC-LCM-SD-6:** The NFO shall send an alarm to the SMO if the Application's current owned resource consumption exceeds the defined resource quotas from the Application descriptor. + +**REQ-SEC-LCM-SD-7:** The comparing process between the Application's current owned resource consumption and the defined resource quotas from the Application descriptor should be triggered periodically by the NFO. + +#### 5.3.2.4 Secure Deletion of Sensitive Data + +##### 5.3.2.4.1 Introduction + +Support for secure deletion of data owned by the Application is included in clause 5.1.8.6 for O-Cloud secure storage requirements and controls. NIST SP 800-88 [75] can provide additional guidance for data sanitization. + +##### 5.3.2.4.2 Requirements + +**REQ-SEC-DEL-1:** Void + +##### 5.3.2.4.3 Security Controls + +**SEC-CTL-DEL-1:** Void + +**SEC-CTL-DEL-2:** Void + +#### 5.3.2.5 Decommissioning of Applications + +##### 5.3.2.5.0 Introduction + +**NOTE:** When an application is decommissioned, it is important to document the entire process. Another crucial task is to archive the legacy data and software for historical purposes. + +##### 5.3.2.5.1 Requirements + +**REQ-SEC-ALM-DECOM-1:** A complete post-decommission report documenting the performed tasks shall be generated. + +**REQ-SEC-ALM-DECOM-2:** Legacy data and software should be archived. + +**REQ-SEC-ALM-DECOM-3:** All trust artifacts associated with an application shall be revoked at the time of decommissioning. + +**EXAMPLE:** Trust artifacts include digital certificates, OAuth tokens, and application identifiers, etc. + +### 5.3.3 Network Protocols and Services + +#### 5.3.3.0 Requirements + +Each O-RAN component serves important network function(s) based on a list of its necessary network protocols and services supported through its network interface(s). Proper, transparent, and secure network protocols and services enabled on each O-RAN component is essential for its overall security posture with the reduced risk. + +#### 5.3.3.1 Requirements + +**REQ-SEC-NET-1:** A list of network protocols and services supported on the O-RAN component shall be clearly documented by its vendor. Unused protocols shall be disabled. + +### 5.3.4 Robustness of Common Transport Protocols + +#### 5.3.4.0 Introduction + +IP, UDP, TCP, SCTP, SSH, HTTP and HTTP2 are the common transport protocols widely used by any O-RAN components for network communications and services. Robust implementation of those common transport protocols can significantly improve the security of each O-RAN component and system overall. + +#### 5.3.4.1 Requirements + +**REQ-SEC-TRAN-1:** Common transport protocols (IP, UDP, TCP, SCTP, SSH, HTTP and HTTP2) used in O-RAN system should be able to handle unexpected inputs (not in-line with protocol specification) without functional compromise. + +NOTE: The unexpected inputs include random mutations of the protocol headers and payloads, as well as targeted fuzzing with state awareness. + +### 5.3.5 Robustness against Volumetric DDoS Attack + +#### 5.3.5.0 Introduction + +Distributed Denial of Service (DDoS) attack is one of the most common security risks for any O-RAN component. DDoS attack often results in service interruption and even worse system crash and prolonged network outage. A volumetric DDoS attack can come from a bad actor or adversary, or a misconfiguration by the operator. + +#### 5.3.5.1 Requirements + +**REQ-SEC-DOS-1:** An O-RAN architecture element with network interface shall be able to withstand network transport protocol based volumetric DDoS attack without system crash and returning to its normal service level after the attack subsides. + +#### 5.3.5.2 Security Controls + +**SEC-CTL-DOS-1:** Void + +### 5.3.6 Robustness of O-RAN architecture element software + +#### 5.3.6.0 Introduction + +The robustness of the software for O-RAN architecture elements is fundamental to the overall security posture. + +#### 5.3.6.1 Requirements + +**REQ-SEC-SYS-1:** Known vulnerabilities in the software of an O-RAN architecture element shall be identified. + +### 5.3.7 Password-Based Authentication + +#### 5.3.7.0 Introduction + +Weak, stolen, and mis-used passwords are some of the common and leading causes of data breaches and methods of gaining access to systems, services, and applications. Password policy and management are applicable to both remote and Web UI login interfaces for user and automated machine password-based authentication on O-RAN components. + +#### 5.3.7.1 Requirements + +**REQ-SEC-PASS-1:** If password is used as an authentication attribute, O-RAN component vendors should follow security best practices. + +**NOTE:** This allows to mitigate risks resulting from different password-based authentication attacks such as brute-forcing, unauthorized password resets, man-in-the-middle, and dictionary attacks. + +#### 5.3.7.2 Security Controls + +**SEC-CTL-PASS-1:** Default passwords should be changed upon installation. Configured passwords should follow the organization's policies for strong passwords. + +**SEC-CTL-PASS-2:** O-RAN components shall support account lock-out for repeated failed login attempts. The number of failed login attempts shall be configurable. + +**NOTE:** The number of attempts may be guided by the organization's policy. + +**SEC-CTL-PASS-3:** Passwords shall be encrypted when stored and transmitted. + +### 5.3.8 Security Log Management + +#### 5.3.8.1 Introduction + +Security log management is "the process for generating, transmitting, storing, analyzing, and disposing of computer security log data. Log management is essential to ensuring that computer security records are stored in sufficient detail for an appropriate period of time. Routine log analysis is beneficial for identifying security incidents, policy violations, fraudulent activity, and operational problems. Logs are also useful when performing auditing and forensic analysis, supporting internal investigations, establishing baselines, and identifying operational trends and long-term problems." Defined in NIST SP 800-92 [58], executive summary. + +#### 5.3.8.2 Generic Requirements + +**REQ-SEC-SLM-1:** An O-RAN component shall support the generation and transmission of security log data. + +#### 5.3.8.3 Requirements for Cluster Node + +##### 5.3.8.3.1 Requirements on Security Log Data Storage + +**REQ-SEC-SLM-TESS-1:** The Security Log data shall be persistently stored in a non-volatile memory. + +**NOTE:** This refers to Security Log data at rest and applies to back-up Security Log data as well. + +**REQ-SEC-SLM-TESS-2:** Any anomalies detected in log settings, configurations, and processes shall be logged. + +**REQ-SEC-SLM-TESS-3:** The O-RAN Network Function(s), the O-Cloud platform and infrastructure, and the SMO Framework shall create Security Log data. + +**REQ-SEC-SLM-TESS-4:** Security Log data shall be created and maintained per App, per xApp, or per rApp. + +**REQ-SEC-SLM-TESS-5:** The created and stored Security Log data shall provide all necessary information to deduce the root cause of a system behaviour. + +**REQ-SEC-SLM-TESS-6:** The Security Log data access management shall be protected. + +**REQ-SEC-SLM-TESS-7:** The access to Security Log data shall be authenticated and authorized. + +**REQ-SEC-SLM-TESS-8:** Any change of access rights to Security Log data shall be logged. + +**REQ-SEC-SLM-TESS-9:** Changing the access rights of security log data is only possible with privileged access rights. + +**REQ- SEC-SLM-TESS-10:** The Security Log data process shall support Log data rotation. Log data rotation in this context refers to a closing of a Log-storage and opening a new Log-storage when the first Log-storage is complete. + +**REQ- SEC-SLM-TESS-11:** The Security Log data rotation process shall be configurable at regular time and when the maximum log size is reached. + +**REQ- SEC-SLM-TESS-12:** The Security Log data process shall log any log rotation reconfiguration. + +**REQ- SEC-SLM-TESS-13:** The system shall be capable of creating, processing, transmitting, and always storing all required security log events. + +##### 5.3.8.3.2 Requirements on Security Log-data in Motion + +**REQ-SEC-SLM-TESM-1:** The Security Log data in motion shall be protected from unauthorized access. + +**REQ-SEC-SLM-TESM-2:** The Security Log data in motion shall be confidentiality, integrity and replay protected. + +**REQ-SEC-SLM-TESM-3:** A mutual authentication shall be performed for any setup of a secure communication channel. + +**REQ-SEC-SLM-TESM-4:** If a Security Log data integrity verification has failed, the Security Log data and a related failure notification shall be logged. + +**REQ-SEC-SLM-TESM-5:** If a Security Log data appears outside of its expected receiving window, the Security Log data and the related notification shall be logged. + +#### 5.3.8.4 Log data Repository + +##### 5.3.8.4.1 Requirements on Storage in Log data Repository + +**REQ-SEC-TESR-1:** The Security Log data stored in the repository shall be protected from unauthorized access. + +**REQ-SEC-TESR-2:** The Security Log data which have been created inside the trusted environment of the repository shall be persistently stored in a non-volatile memory. + +**NOTE:** This refers to Log data at rest and applies to back-up Log data. + +**REQ-SEC-TESR-4:** Security Log data from different cluster node(s) shall be stored isolated from each other. + +**REQ-SEC-TESR-5:** The Security Log data repository shall grant write only operation to cluster node(s). + +**REQ-SEC-TESR-6:** Security Log data which are stored in the repository shall be confidentiality and integrity protected. + +**REQ-SEC-TESR-7:** The Security Log data repository shall support attribute-based (ABAC) access management according to NIST SP800-162 [67]. + +**REQ-SEC-TESR-8:** The Security Log data access management shall support operations for read, write, edit, delete, copy, execute and modify. + +**REQ-SEC-TESR-9:** The access management ABAC mechanisms shall include the Subject Attributes, the Resource Objects Attributes, the Access Control Rules (policy), and the environmental conditions. + +**REQ-SEC-TESR-10:** The Log data repository shall create and store Security Log data in a non-volatile memory. + +**REQ-SEC-TESR-11:** Security Log data in use shall be protected from unauthorized access. + +#### 5.3.8.5 Secure storage of security log data + +##### 5.3.8.5.1 Introduction + +Security log data storage involves the safekeeping and retention of security log data for a certain period of time. Security log data storage should ensure that all data of security events is retained reliably for a certain time so that no data is lost or altered, and access to the data is restricted to authorized personnel only. + +##### 5.3.8.5.2 Requirements + +**REQ-SEC-SLM-SST-1:** Security log data shall be stored in a centralized location for easy management and analysis. + +**REQ-SEC-SLM-SST-2:** Security log data shall be stored in a tamper-proof manner to ensure their integrity and authenticity. + +**REQ-SEC-SLM-SST-3:** Retention policies for security log data shall be established to determine how long logs shall be kept. + +**REQ-SEC-SLM-SST-4:** Access to the log storage shall be restricted to authorized personnel only. + +**REQ-SEC-SLM-SST-5:** Access to the log storage shall be logged. + +**REQ-SEC-SLM-SST-6:** Backup of the log storage shall be performed regularly. + +**REQ-SEC-SLM-SST-7:** O-RAN elements shall be authorized to only send security log data to centralized log storage. + +##### 5.3.8.5.3 Security Controls + +**SEC-CTL-SLM-SST-1:** Centralized storage for security log data should be realized using centralized logging servers or cloud-based services. + +**SEC-CTL-SLM-SST-2:** Tamper-proof storage of security log data may be achieved through digital signature, encryption, and hashing techniques. + +**SEC-CTL-SLM-SST-3:** The retention period should be based on legal, regulatory, and compliance requirements, as well as the organization's own policies. + +#### 5.3.8.6 Secure Transfer of security log data + +##### 5.3.8.6.1 Introduction + +Security log transfer involves the movement of security log data from one location to another, such as from a local device to a centralized logging server. + +##### 5.3.8.6.2 Requirements + +**REQ-SEC-SLM-STR-1:** Security log data shall be confidentiality- and integrity- protected during transfer to protect them from unauthorized access or tampering. + +**REQ-SEC-SLM-STR-2:** The parties involved in the security log transfer shall mutually authenticate each other to ensure that the logs are coming from a trusted source and going to a trusted destination. Failures detected during the authentication shall be logged. + +**REQ-SEC-SLM-STR-3:** Mechanisms shall be in place to ensure the integrity of the security log data during transfer. + +**REQ-SEC-SLM-STR-4:** The log transfer process shall be auditable to enable the tracking and identification of any unauthorized or suspicious log transfers. + +**REQ-SEC-SLM-STR-5:** An O-RAN component may support log streaming for security log events. + +##### 5.3.8.6.3 Security Controls + +**SEC-CTL-SLM-STR-1:** Digital signatures or hash-based message authentication codes (HMACs) may be used to provide integrity protection of security log data. + +**SEC-CTL-SLM-STR-2:** An O-RAN component may support the transport of Syslog as defined in RFC 5424 [64] over TLS as defined in RFC 5425 [65] for log streaming of security log events. + +#### 5.3.8.7 Log Format + +##### 5.3.8.7.1 Introduction + +Each O-RAN component produces logs in various formats. The logs are collected at a central and trusted location where the logs are unified. + +##### 5.3.8.7.2 Requirements + +**REQ-SEC-SLM-FMT-1:** Security logs shall be formatted in a consistent, standard, and machine-readable format that maintains backward compatibility with previous log format versions. + +#### 5.3.8.8 Log Fields + +##### 5.3.8.8.1 Introduction + +To enable effective security analytics, it is important to include additional details in the security logs of the security event. These details help to identify adversarial operations within the O-RAN environment. A typical security log entry consists of two main parts: the log fields and the log message. The log fields provide metadata about the security log entry, while the log message contains the actual content and details of the security event being logged. The requirements specified in this clause pertain to the log fields. + +##### 5.3.8.8.2 Requirements + +**REQ-SEC-SLM-FLD-1:** Security logs shall include the date and time of the security event for each log entry, using a consistent and standardized format that logs time to at least the second. + +**REQ-SEC-SLM-FLD-2:** Security logs shall record the location of the security event for each log entry. For network transactions, the location shall incorporate both the source and destination IP addresses. In cases where security events transpire within a single component, the location field shall only contain the source IP address. + +**REQ-SEC-SLM-FLD-3:** Security logs shall include the entity that is the cause of the security event for each log entry. + +##### 5.3.8.8.3 Security Controls + +**SEC-CTL-SLM-FLD-1:** Security logs should use the ISO 8601 date and time format [62]. + +**SEC-CTL-SLM-FLD-2:** Security logs shall use IP addresses for the location field. + +#### 5.3.8.9 Authenticated Time Stamping and Missing Time Source + +##### 5.3.8.9.1 Requirements + +**REQ-SEC-SLM-ATS-1:** All network functions shall be synchronised to a common and authenticated time source. + +**REQ-SEC-SLM-ATS-2:** Any successful as well as the unsuccessful synchronization to the common time source shall be logged. + +**REQ-SEC-SLM-ATS-3:** The Security Log-data shall be time-stamped with the system time in case of unsuccessful synchronisation to a common time source. + +**REQ-SEC-SLM-ATS-4:** The Security Log-data recording shall take place in the order in which the (security) log events occur. + +**REQ-SEC-SLM-ATS-5:** The Security Log data shall contain a timestamp that includes a timezone. + +##### 5.3.8.9.2 Security Controls + +###### 5.3.8.9.2.1 Authenticated Time Stamping + +**SEC-CTL-SLM-ATS-1:** The Network Time Protocol (NTP) version 4 should be supported as specified by RFC5905[60] for the support of authenticated time stamping. + +**SEC-CTL-SLM-ATS-2:** If NTPv4 authentication is in use, then AES-CMAC as specified by RFC4493 [78] shall be supported. In this use case the NTP client can verify the integrity of the received NTP-packet. + +**SEC-CTL-SLM-ATS-3:** If NTP security (as specified by RFC5905 [60]) is in use for the integrity and replay protection of NTP-packets, then NTS (RFC8915 [63]) shall be supported. + +NOTE: In this use case the NTP client may verify the authenticity of the NTP packets by use of X.509 PKI infrastructure. + +###### 5.3.8.9.2.2 Common Time Source + +**SEC-CTL-SLM-CTS-1:** The Time Stamp representation should be in a standardized format, and the format in use should be logged. For reference to the formatting please refer to RFC 3339 [61] and ISO 8601 [62]. + +#### 5.3.8.10 Security Log Management Due Diligence and Auditing + +##### 5.3.8.10.1 Requirements + +**REQ-SEC-SLM-DDA-1:** The organization should define a policy and procedure for security logging. The security log management policy shall define periodic audits to confirm that logging standards and guidelines are being followed throughout the organization. + +**REQ-SEC-SLM-DDA-2:** The organization should ensure that the policies and procedures in the log management process are being performed properly. + +**REQ-SEC-SLM-DDA-3:** The security log management should be prioritized appropriate throughout the organization. + +**REQ-SEC-SLM-DDA-4:** The organization should prioritize its goals based on balancing the organization's reduction of risk with the time and resources needed to perform security log management functions. + +**REQ-SEC-SLM-DDA-5:** The organization should create and maintain a secure log management infrastructure. + +**REQ-SEC-SLM-DDA-6:** The organization should create an infrastructure that is robust enough to handle not only expected volumes of log data, but also peak-data volumes during extreme situations. + +**REQ-SEC-SLM-DDA-7:** The organization should provide adequate support for all staff with log management responsibilities. + +**REQ-SEC-SLM-DDA-8:** As part of the log management planning process, the organization should define the roles and responsibilities of individuals and teams who are expected to be involved in log management. + +**REQ-SEC-SLM-DDA-9:** The security log management policy should define how to provide confidentiality, integrity, and availability of the results of log analysis which are to be protected while at rest, in use and in motion. + +**REQ-SEC-SLM-DDA-10:** The security log management policy should provide a definition of how to handle inadvertent disclosures of sensitive information that is recorded in logs. + +**REQ-SEC-SLM-DDA-11:** The security log management policy should provide a definition of which type of log-data to be analysed and how often. + +##### 5.3.8.10.2 Security Controls + +**SEC-CTL-SLM-DDA-1:** Testing and validation should be used to ensure that the policies and procedures in the log management process are being performed properly. + +**SEC-CTL-SLM-DDA-2:** While defining the log management scheme, organizations should ensure that they provide the necessary training to relevant staff regarding their log management responsibilities as well as skill instruction for the needed resources to support log management. + +**NOTE:** The support also includes the provision of log management tools and tool documentation, the provision of technical guidance on log management activities, and the disseminating information to log management staff. + +**SEC-CTL-SLM-DDA-3:** The organizations should assign team and individual roles which are often involved in log management as follows: + +- **System and network administrators**, who are usually responsible for configuring logging on individual systems and network devices, analysing those logs periodically, reporting on the results of log management activities, and performing regular maintenance of the logs and logging software. +- **Security administrators**, who are usually responsible for managing and monitoring the log management infrastructures, configuring logging on security devices (e.g., firewalls, network-based intrusion detection systems, antivirus servers), reporting on the results of log management activities, and assisting others with configuring logging and performing log analysis. +- **Computer security incident response teams**, who use log data when handling some incidents. +- **Application developers**, who may need to design or customize applications so that they perform logging in accordance with the logging requirements and recommendations. +- **Information security officers**, who may oversee the log management infrastructures. +- **Chief information officers (CIO)**, who oversee the IT resources that generate, transmit, and store the logs +- **Auditors**, who may use log data when performing audits. Individuals involved in the procurement of software that should or can generate computer security log data. + +#### 5.3.8.11 Security Events to be Logged + +##### 5.3.8.11.1 Introduction + +During O-RAN operations, components generate many events. Some of these events have security utility and are thus termed security events. Logging these security events is critical to maintaining a secure O-RAN environment. For convenience, security event log requirements are organized by high-level categories. These categories are mapped against the following O-RAN architectural elements: SMO, O-RAN Network Functions (NF), and O-Cloud (see Table 5.3.8.11.1-1). + +- The SMO has security events related to management and orchestration. +- O-RAN Network Functions have application security events. +- O-Cloud has both network security events and system security events related to operating systems, hypervisors, and container runtimes. +- The following security event types occur in all O-RAN components (SMO, O-RAN NF, and O-Cloud): account and identity event, data access events, and general security events. + +Table 5.3.8.11.1-1: Types of Security Events by O-RAN Component + +| Types of Security Events | O-RAN Architectural Component | | | +|--------------------------|-------------------------------|----------|---------| +| | SMO | O-RAN NF | O-Cloud | + +| | | | | +|-------------------------------------|---|---|---| +| Management and Orchestration Events | X | | | +| Application Events | | X | | +| Network Events | | | X | +| System Events | | | X | +| Data Access Events | X | X | X | +| Account and Identity Events | X | X | X | +| General Security Events | X | X | X | + +##### 5.3.8.11.2 Network Security Event Log Requirements + +**REQ-SEC-SLM-NET-EVT-1:** O-Cloud shall log all physical and virtual network events related to creating and modifying network configurations, enabling, and disabling ports, network connections, and packets over limit from the firewalls from all host operating systems, hypervisors, and container engines. + +##### 5.3.8.11.3 System Security Event Log Requirements + +###### 5.3.8.11.3.1 General O-Cloud Security Events + +###### 5.3.8.11.3.1.1 Requirements + +**REQ-SEC-SLM-GEN-EVT-1:** O-Cloud shall log the following resource-related events: shortages, system crashes, reboots, shutdowns, resource creation, and deletion from all host operating systems, hypervisors, and container engines. + +**REQ-SEC-SLM-GEN-EVT-2:** O-Cloud shall log when maintenance activity is undertaken for host operating systems, hypervisors, and container engines. + +**REQ-SEC-SLM-GEN-EVT-3:** O-Cloud shall log the creation of scheduled jobs and the particular time the job will run for all host operating systems, hypervisors, and container engines. + +**REQ-SEC-SLM-GEN-EVT-4:** O-Cloud shall log a security event when driver tampering is detected. + +**NOTE:** This includes but is not limited to modifications made to the main driver executable and any associated files, libraries, dependencies, or configuration files. + +**REQ-SEC-SLM-GEN-EVT-5:** O-Cloud shall log a security event when it detects unauthorized changes to the O-Cloud hardware resource configuration. + +**REQ-SEC-SLM-GEN-EVT-6:** O-Cloud shall log a security event when it detects unauthorized changes to the Application configuration. + +###### 5.3.8.11.3.1.2 Security Controls + +**SEC-CTL-SLM-GEN-EVT-1:** O-Cloud shall log a security event if driver signature verification fails. + +**SEC-CTL-SLM-GEN-EVT-2:** O-Cloud shall implement a robust File Integrity Monitoring (FIM) system that continuously monitors the integrity of all driver-related files, including executables, libraries, configuration files, and dependencies. The FIM system shall be configured to calculate cryptographic hashes of these files as baseline values and regularly compare the current cryptographic hashes with their baseline hashes stored in the FIM system. + +**SEC-CTL-SLM-GEN-EVT-3:** O-Cloud shall log a security event if any hashes of driver files do not match their baseline values. + +**SEC-CTL-SLM-GEN-EVT-4:** Baseline configurations for the hardware resource shall be established by the SMO, and regularly compared to the current state. + +**SEC-CTL-SLM-GEN-EVT-5:** O-Cloud shall log a security event when it detects unauthorized deviation from the O-Cloud hardware resource configuration baseline. + +**SEC-CTL-SLM-GEN-EVT-6:** Baseline configurations for each Application shall be established by the SMO, and regularly compared to the current state. + +**SEC-CTL-SLM-GEN-EVT-7:** O-Cloud shall log a security event when it detects unauthorized deviation from the Application configuration baseline. + +**NOTE:** Log management systems, such as SIEM, fall beyond the purview of O-RAN and are considered external entities. In the context of O-Cloud, it's recommended to set up these log management systems to dispatch notifications to the administrator when any of the following security events take place: + +- Driver signature verification fails. +- Driver file hash verification fails. +- Unauthorized deviations from the O-Cloud hardware resource configuration baseline are detected. +- Unauthorized deviations from the application configuration baseline are detected. + +###### 5.3.8.11.3.2 Hypervisor Specific System Security Events + +**REQ-SEC-SLM-HYP-EVT-1:** O-Cloud shall log all changes to operating system configurations, hypervisor configurations, changes to virtualization settings, and changes to resource allocations. + +**REQ-SEC-SLM-HYP-EVT-2:** O-Cloud shall log all hypervisor events related to attaching or detaching virtual disks. + +**REQ-SEC-SLM-HYP-EVT-3:** O-Cloud shall log all hypervisor events related to creating, starting, stopping, restarting, and deleting virtual machines. + +###### 5.3.8.11.3.3 Container Engine Specific System Events + +**REQ-SEC-SLM-CON-EVT-1:** O-Cloud shall log all image repository events related to additions, modifications, and removal of images. + +**REQ-SEC-SLM-CON-EVT-2:** O-Cloud shall log all container engine events related to volume creation, deletion, and mounting. + +**REQ-SEC-SLM-CON-EVT-3:** O-Cloud shall log all container engine events related to creating, starting, stopping, restarting, and deleting containers. + +##### 5.3.8.11.4 Application Security Event Log Requirements + +**REQ-SEC-SLM-APP-EVT-1:** O-RAN Network Functions shall log any errors or exceptions generated. + +**REQ-SEC-SLM-APP-EVT-2:** O-RAN Network Functions shall log the use of any dynamically loaded libraries, including the name and version information of the library being loaded. + +##### 5.3.8.11.5 Data Access Security Event Log Requirements + +**REQ-SEC-SLM-DAT-EVT-1:** O-RAN components shall log successful file additions, deletions, and unsuccessful attempts due to errors and authorization issues. + +**REQ-SEC-SLM-DAT-EVT-2:** O-RAN components should log successful file reads and writes. + +**REQ-SEC-SLM-DAT-EVT-3:** O-RAN components shall log unsuccessful attempts of file reads and writes due to errors and authorization issues. + +**REQ-SEC-SLM-DAT-EVT-4:** O-RAN components shall log successful directory additions, deletions, and unsuccessful attempts due to errors and authorization issues. + +**REQ-SEC-SLM-DAT-EVT-5:** O-RAN components shall log successful database or data store additions, deletions, and unsuccessful attempts due to errors and authorization issues. + +**REQ-SEC-SLM-DAT-EVT-6:** O-RAN components should log successful database or data store reads and writes. + +**REQ-SEC-SLM-DAT-EVT-7:** O-RAN components shall log unsuccessful attempts of database and data store reads and writes. + +**REQ-SEC-SLM-DAT-EVT-8:** O-RAN components shall log permission changes to files, directories, databases, or data stores. + +##### 5.3.8.11.6 Account and Identity Security Event Log Requirements + +**REQ-SEC-SLM-AAI-EVT-1:** O-RAN components shall log account creation, modification, deletion, and unsuccessful attempts. + +**REQ-SEC-SLM-AAI-EVT-2:** O-RAN components shall log changes to account privilege levels and unsuccessful attempts. + +**REQ-SEC-SLM-AAI-EVT-3:** O-RAN components shall log successful group membership changes for accounts and unsuccessful change attempts. + +**REQ-SEC-SLM-AAI-EVT-4:** O-RAN components shall log successful and unsuccessful authentication attempts for accounts. + +**REQ-SEC-SLM-AAI-EVT-5:** O-RAN components shall log successful and unsuccessful authorization attempts to create a session or initiate a transaction. + +**REQ-SEC-SLM-AAI-EVT-6:** O-RAN components shall log the termination of sessions or transactions. + +**REQ-SEC-SLM-AAI-EVT-7:** O-RAN components shall log the occurrence of downgraded privileges or elevation of privileges for accounts. + +**REQ-SEC-SLM-AAI-EVT-8:** Void + +**REQ-SEC-SLM-AAI-EVT-9:** O-RAN components shall log transactions successfully executed by accounts and unsuccessful attempts. + +**REQ-SEC-SLM-AAI-EVT-10:** O-RAN components shall log requests that do not require an authenticated account. + +##### 5.3.8.11.7 General Security Event Log Requirements + +**REQ-SEC-SLM-GSE-1:** O-RAN components shall log the activation and deactivation of security software related to security logging, firewalls, malware protection, data loss prevention (DLP), and intrusion detection systems (IDS). + +**REQ-SEC-SLM-GSE-2:** O-RAN components shall log the use of administrative privileges. + +**REQ-SEC-SLM-GSE-3:** O-RAN components shall log any change to a security-related configuration item, including a description of the configuration change. + +**REQ-SEC-SLM-GSE-4:** O-RAN components shall log the occurrence of viewing, renewing, exporting, importing, modifying, and deleting of certificates and keys. The logged data for these events shall not include any sensitive information related to the certificates or the keys. + +**REQ-SEC-SLM-GSE-5:** O-RAN components shall log the occurrence of cryptographic operations on resources involved in signatures, encryption, decryption, hashing, key generation, and key destruction. The logged data for these events shall not include any sensitive information related to the cryptographic operations. + +**REQ-SEC-SLM-GSE-6:** O-RAN components shall log security patches submitted but not applied. + +#### 5.3.8.12 Log data Lifecycle Management + +**REQ-SEC-LCSS-2:** The Security Log data process shall support Log data rotation. + +NOTE: Log data rotation in this context refers to a closing of a Log-storage and opening a new Log-storage when the first Log-storage is complete. + +**REQ-SEC-LCSS-3:** The Security Log data rotation process shall be configurable at regular time intervals and when the maximum log size is reached. + +**REQ-SEC-LCSS-4:** The Security Log data process shall log any log rotation reconfiguration. + +**REQ-SEC-LCSS-5:** The system shall be capable of creating, processing, transmitting, and always storing all required security log events. + +#### 5.3.8.13 Requirements on Security Log data Policy + +**REQ-SEC-POL-5:** The archived Security Log data and their storage media shall be checked periodically to determine whether the Security Log data is accessible. + +**REQ-SEC-POL-6:** The archived Log data and their media shall be physically protected. + +**REQ-SEC-POL-7:** The personally identifiable information (PII) shall be removed from archived Security Log data. For details on PII please refer to ([68]). + +**REQ-SEC-POL-8:** The archived Security Log data shall be integrity and confidentiality protected. + +**REQ-SEC-POL-9:** For the Security Log data lifecycle a policy shall be supported for log retention and log preservation. If this provides filter options, then security Log data shall not be filtered out. + +**REQ-SEC-POL-10:** The log policy shall include requirements for log generation, log transmission, storage and disposal, and log analysis. + +#### 5.3.8.14 Preventing (D)DoS to Security Log Data + +##### 5.3.8.14.1 General + +The Requirements below are applicable to the vendors of the log management infrastructure. + +##### 5.3.8.14.2 Requirements + +**REQ-SEC-SLM-DoS-1:** The log management infrastructure should be designed to support typical and peak volume of log data to be processed per hour and day [58]. + +**REQ-SEC-SLM-DoS-2:** The log management infrastructure should support the handling of peak situations for extreme situations [58]. + +NOTE 1: Extreme situations in this context refer to widespread malware incidents, vulnerability scanning, and penetration tests that might cause unusual large number of log entries. + +**REQ-SEC-SLM-DoS-3:** The log management infrastructure should provide notifications at different log data volumes. + +NOTE 2: This refers to the introduction of escalation levels at different log data volumes. + +**REQ-SEC-SLM-DoS-4:** The log management infrastructure should provide notifications at different log data event rates. + +NOTE 3: This refers to the introduction of escalation levels at different log data event rates. + +**REQ-SEC-SLM-DoS-5:** The log management infrastructure should support mechanisms for log data redundancy. + +**REQ-SEC-SLM-DoS-6:** The log management infrastructure should trigger the archiving of log data based on the level of escalation achieved. + +NOTE 4: The escalation level may be triggered by increased log data volume or log data event rates. + +**REQ-SEC-SLM-DoS-7:** The log management infrastructure should trigger the retention of log data based on the level of escalation achieved. + +NOTE 5: The escalation level may be triggered by increased log data volume or log data event rates. + +#### 5.3.8.15 Preventing Tampering of Log Data + +##### 5.3.8.15.1 General + +The Requirements below are applicable to the vendors of the log management infrastructure. + +##### 5.3.8.15.2 Requirements + +**REQ-SEC-SLM-TLD-1:** The log management infrastructure should support access management for log data. + +**REQ-SEC-SLM-TLD-2:** The log management infrastructure should support real time logging (log data streaming). + +**REQ-SEC-SLM-TLD-3:** The log management infrastructure should support replication of log data. + +**REQ-SEC-SLM-TLD-4:** The log management infrastructure should support the derivation of digests of log-data to existing and preceding digests with the aim to keep the cryptographic chain and to attest the completeness and the integrity of the security events. + +### 5.3.9 Certificate Management Framework + +#### 5.3.9.1 Requirements + +##### 5.3.9.1.1 PNFs + +**REQ-SEC-CMF-PNF-1:** An O-RAN PNF requiring a PKI certificate shall support certificate management protocol. + +**REQ-SEC-CMF-PNF-2:** In order to facilitate vendor certificate-based initial enrolment of PNFs, vendors shall pre-install vendor-signed certificates in PNFs. + +**REQ-SEC-CMF-PNF-3:** In order to facilitate vendor certificate-based initial enrolment of PNFs, operators shall pre-provision the FQDN/IP address of RA/CA to PNFs. + +EXAMPLE 1: pre-configurations before deployment + +EXAMPLE 2: startup installation procedure as defined in [14], clause 6.1. + +**REQ-SEC-CMF-PNF-4:** PNFs which use vendor-signed certificates for initial certificate enrolment should monitor the expiry of the vendor root CA certificate or any of the sub-CA certificates in the trust chain used to sign the certificate. + +**REQ-SEC-CMF-PNF-5:** When the expiry of the vendor root CA certificate or any of the sub-CA certificates in the trust chain is approaching, PNFs should raise notifications (alarms) with increasing levels of severity as the expiry date gets closer. + +**REQ-SEC-CMF-PNF-6:** In the event the secure storage space has exceeded the configured storage limits, the PNF should raise notifications and/or alarms. + +##### 5.3.9.1.2 VNFs/CNFs + +**REQ-SEC-CMF-VNF\_CNF-1:** The O-Cloud shall support a certificate management protocol for use by O-RAN VNFs/CNFs that require a PKI certificate. + +**REQ-SEC-CMF-VNF\_CNF-2:** An O-RAN VNF/CNF requiring a PKI certificate directly from a CA/RA, without O-Cloud involvement, shall support a certificate management protocol. + +**REQ-SEC-CMF-VNF\_CNF-3:** SMO shall configure all the initial information needed for certificate enrolment during NF Deployment of a VNF/CNF. + +##### 5.3.9.1.3 Any NF (PNF/VNF/CNF) + +**REQ-SEC-CMF-ANYNF-1:** Any offline or out-of-band (automated or manual) PSK/Refnum generation, distribution and provisioning systems shall provide PSK/Refnum values only to an authorized PNF/CNF/VNF. + +**REQ-SEC-CMF-ANYNF-2:** NFs shall raise alarms/notifications and/or security events alerting about the certificates about to expire in the near future with increasing severity levels as the expiry date approaches. + +**REQ-SEC-CMF-ANYNF-3:** SMO or certificate management systems should instruct NFs to trigger certificate renewal procedures according to operator's policies. + +EXAMPLE 1: Policy 1: instruct NFs to trigger certificate renewals in a staggered manner + +EXAMPLE 2: Policy 2: instruct NFs to trigger certificate renewals according to resource availability + +**REQ-SEC-CMF-ANYNF-4:** NFs shall provide interfaces to allow configuration of the advance alarms/notifications/security events interval prior to certificate expiry for different severity levels. + +EXAMPLE 3: Configuration: Minor alarm N1 days before expiry, Major alarm, and security event N2 days before expiry, Critical alarm, and security events N3 days before expiry of certificates, Critical alarm, and security event every day after expiry. + +**REQ-SEC-CMF-ANYNF-5:** NFs shall trigger certificate renewal procedure before the certificate expiry using policies provided by the operator. + +EXAMPLE 4: Policy 1: Trigger renewal N1/N2/N3 days before expiry. + +EXAMPLE 5: Policy 2: Trigger renewal when instructed by SMO or certificate management. + +**REQ-SEC-CMF-ANYNF-6:** NFs shall provide interfaces to enable certificate management systems to trigger certificate renewal before the expiry. + +**REQ-SEC-CMF-ANYNF-7:** NFs shall send a notification to the SMO indicating the success or failure state after the certificate renewal completion. + +**REQ-SEC-CMF-ANYNF-8:** NFs shall raise a critical alarm as well as log security events if the certificate for NF(s) has expired. + +**REQ-SEC-CMF-ANYNF-9:** NFs should raise a critical alarm as well as log security events if the certificate renewal has failed. + +**REQ-SEC-CMF-ANYNF-10:** In the event the newly installed/renewed certificate fails, the NF shall continue to use its previous certificate until that certificate expires. + +**REQ-SEC-CMF-ANYNF-11:** CRL servers (either LDAP or HTTP access as stated in clause 6.1.1 of the 3GPP TS 33.310[2]) should be used by NFs to check the revocation status of certificates. + +**REQ-SEC-CMF-ANYNF-12:** In the event of failure to connect with CRL servers, notifications and/or alarms should be raised by NFs. + +##### 5.3.9.1.4 O-Cloud + +**REQ-SEC-CMF-O-CLOUD-1:** In the event the secure storage space has exceeded the configured storage limits, the O-Cloud should raise notifications and/or alarms. + +#### 5.3.9.2 Security Controls + +##### 5.3.9.2.1 PNFs + +**SEC-CTL-CMF-PNF-1:** An O-RAN PNF requiring a PKI certificate shall support CMPv2 as specified in O-RAN Security Protocols Specifications [3], clause 4.6. + +##### 5.3.9.2.2 VNFs/CNFs + +**SEC-CTL-CMF-VNF\_CNF-1:** Void + +**SEC-CTL-CMF-VNF\_CNF-2:** An O-RAN VNF/CNF requiring a PKI certificate from a CA/RA shall support CMPv2 as specified in O-RAN Security Protocols Specifications [3], clause 4.6. + +##### 5.3.9.2.3 Any NF (PNF/VNF/CNF) + +**SEC-CTL-CMF-ANYNF-1:** NFs may establish TLS connection using renewed certificates before terminating existing TLS connections. + +**SEC-CTL-CMF-ANYNF-2:** NFs may terminate any established TLS connection after the renewed certificates are validated and re-establish TLS connection with new certificate. + +**SEC-CTL-CMF-ANYNF-3:** NFs may wait for already established TLS connections to close before applying the renewed certificate for new TLS connections. + +### 5.3.10 Application Programming Interfaces (APIs) + +#### 5.3.10.1 Introduction + +An Application Programming Interface (API) is implemented by a software program to be able to interact with other software programs as defined in [i.16]. An API is a set of libraries or specifications which allows interaction with an external artefact or agent from a third party. The APIs which comply with the REST constraints are said to be RESTful and refer to the description of a communication interface that allows interacting with a system based on the REST architecture style. + +The specification of RESTful APIs plays its role at given an interface between two components in the system architecture, a RESTful API provides the implementation details for the communication between these two entities, which are then identified as the API Producer (or Server) and the API Consumer (or Client). + +The security requirements in this clause provide protections against the vulnerabilities and security risks identified in the OWASP API Security Project Top 10 2023 vulnerabilities and security risks of Application Programming Interfaces (APIs) [i.9]. APIs as referred to in this clause are transactional APIs based on REST or gRPC. The terms client, resource owner, and resource server are defined in IETF RFC 6749 [34]. + +#### 5.3.10.2 Security Requirements + +**REQ-SEC-API-1:** APIs used in O-RAN to access an internal or external data source should perform object-level authorization checks. + +**REQ-SEC-API-2:** O-RAN endpoints using APIs shall support certificate-based authentication. + +**REQ-SEC-API-3:** O-RAN endpoints using APIs may support password-based authentication that is a factor used in multi-factor authentication (MFA). + +**REQ-SEC-API-3a:** Password-based single-factor authentication should not be used when O-RAN endpoints are using APIs. + +**REQ-SEC-API-4:** O-RAN endpoints using APIs should provide strong authorization with the principle of least privilege. + +**REQ-SEC-API-5:** O-RAN endpoints using APIs shall validate the authenticity of tokens. Unsigned JWT tokens shall not be accepted. + +**REQ-SEC-API-6:** O-RAN endpoints shall validate API client requests to return sensitive data. + +**REQ-SEC-API-7:** APIs used in O-RAN shall have confidentiality and integrity protection for data-in-transit. + +**REQ-SEC-API-8:** APIs used in O-RAN shall implement a schema-based validation mechanism to enforce returned data. + +**REQ-SEC-API-9:** APIs used in O-RAN shall impose a restriction on the size and number of resources that a client requests. + +**REQ-SEC-API-10:** APIs used in O-RAN shall support authorization that denies all access by default and requires explicit grants to specific roles for access to every function. + +**REQ-SEC-API-11:** APIs used in O-RAN shall default-deny properties that should not be accessed by clients. + +**REQ-SEC-API-12:** APIs used in O-RAN shall only be accessed by valid HTTP verbs. All other HTTP verbs should be disabled. + +**REQ-SEC-API-13:** APIs used in O-RAN shall validate, filter, and sanitize client-provided data and other data coming from integrated systems. Data validation shall be performed using a single, trustworthy, and actively maintained library. Special characters shall be escaped using the specific syntax for the target interpreter. + +**REQ-SEC-API-14:** APIs used in O-RAN shall limit the number of returned records to prevent mass disclosure in case of injection. + +**REQ-SEC-API-15:** APIs used in O-RAN shall log all failed authentication attempts, denied access, and input validation errors. + +#### 5.3.10.3 Security Controls + +**SEC-CTL-API-01:** API client and server shall support mTLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2, with PKI using X.509v3 certificates for mutual authentication. + +**SEC-CTL-API-02:** API server shall support OAuth 2.0 resource server functionality, as specified in O-RAN Security Protocols Specifications [3], clause 4.7, for service requests received from API clients. + +**SEC-CTL-API-03:** API server shall support OAuth 2.0 resource owner functionality, as specified in O-RAN Security Protocols Specifications [3], clause 4.7, for service requests received from API clients. + +**SEC-CTL-API-04:** API client shall support OAuth 2.0 client functionality, as specified in O-RAN Security Protocols Specifications [3], clause 4.7 for each service request. + +**SEC-CTL-API-05:** API client and server shall support TLS, as specified in O-RAN Security Protocols Specifications [3], clause 4.2, for protection of data-in-transit. + +### 5.3.11 Trust Anchor Provisioning + +#### 5.3.11.0 General + +Before an O-RAN component can establish a mutual TLS connection with a signaling peer, the O-RAN component needs to be able to trace the peer's certificate path to a valid trust anchor. + +##### 5.3.11.1 Requirements + +**REQ-SEC-TAP-1:** An O-RAN PNF using PKIX certificates shall be shipped with one or more pre-provisioned Trust Anchors. + +**REQ-SEC-TAP-1a:** Pre-provisioned Trust Anchors that are used by an O-RAN PNF using PKIX certificates may be vendor-signed certificates or operator-signed certificates. + +**REQ-SEC-TAP-2:** An O-RAN PNF shall support the secure storage of the trust anchors in a secure element or a secure enclave such that they cannot be tampered with or modified. + +**REQ-SEC-TAP-3:** An O-RAN PNF using PKIX certificates shall enable an authorized function to recover the list of provisioned trust anchors and associated public keys. + +**REQ-SEC-TAP-4:** An O-RAN PNF shall be able to be securely provisioned with new trust anchors and have an existing trust anchor replaced, for events such as expiration. + +**REQ-SEC-TAP-5:** An O-RAN PNF shall log an event for each trust anchor provisioning operation. + +#### 5.3.11.2 Security Controls + +**SEC-CTL-TAP-1:** An O-RAN PNF shall support CMPv2, as specified in O-RAN Security Protocols Specifications [3], clause 4.6, for trust anchor provisioning. + +**SEC-CTL-TAP-2:** An O-RAN PNF may support voucher-based protocols [69] to enable an O-RAN function to be securely provisioned with a new trust anchor. + +**SEC-CTL-TAP-3:** An O-RAN PNF may support BRSKI [70] for trust anchor provisioning. + +**SEC-CTL-TAP-4:** An O-RAN PNF may support SZTP [71] for trust anchor provisioning. + +**SEC-CTL-TAP-5:** An O-RAN PNF may support 3GPP SCS [72], [73], [74] for download of initial security configuration. + +### 5.3.12 AI/ML Security + +#### 5.3.12.1 Introduction + +This clause outlines the security requirements and controls for AI/ML in the O-RAN architecture, with the goal of ensuring the confidentiality, integrity, and availability of AI/ML models, data, and decision-making processes. For requirements and security controls on logging of AI/ML related security events see clause 5.1.8 of the present document. + +#### 5.3.12.2 Requirements + +**REQ-SEC-AIML-1:** Access to AI/ML models shall be authenticated and authorized. + +**REQ-SEC-AIML-2:** The systems controlling access to AI/ML models shall enforce access control policies that align with the principle of least privilege. + +**REQ-SEC-AIML-3:** AI/ML models shall be protected in terms of integrity and confidentiality at rest, in use and in transit. + +**REQ-SEC-AIML-4:** Input data used for AI model training, testing and inference shall be sourced only from verified sources. + +**REQ-SEC-AIML-5:** Data used for or produced by AI model training, testing and inference shall be protected in terms of integrity and confidentiality at rest, in use and in transit. + +**REQ-SEC-AIML-6:** Access to data used for or produced by AI model training, testing and inference shall be authenticated and authorized. + +**REQ-SEC-AIML-7:** Access control to data used for or produced by AI model training, testing and inference shall enforce access control policies that align with the principle of least privilege. + +**REQ-SEC-AIML-8:** An AI/ML model training process may incorporate differential privacy to prevent the model from memorizing sensitive information, thereby reducing the risk of data leakage. + +**REQ-SEC-AIML-9:** An AI/ML model inference process may apply differential privacy to the outputs of AI/ML models, ensuring that query responses do not reveal sensitive information about individual data points. + +**REQ-SEC-AIML-10:** AI/ML Training service Producer may check that the AI/ML Model is not poisoned after the AI/ML Model evaluation. + +NOTE: Clause 5.1.3.2.4 of [i.17] details the Model evaluation for ML Testing + +**REQ-SEC-AIML-11:** AI/ML Training service Producer may evaluate that the AI/ML Model is not poisoned, before notifying the AI/ML training services Consumer about the completion of the training. + +![Diagram illustrating a deep neural network AI/ML model split across five inference hosts. The model is represented as a series of layers (input, hidden, and output) distributed across five hosts. Inference input enters the first host, and inference output exits the last host. The model is split across five inference hosts, with each host containing a portion of the neural network layers.](1f46afdddbf1c41f2431ded35ad03fce_img.jpg) + +Diagram illustrating a deep neural network AI/ML model split across five inference hosts. The model is represented as a series of layers (input, hidden, and output) distributed across five hosts. Inference input enters the first host, and inference output exits the last host. The model is split across five inference hosts, with each host containing a portion of the neural network layers. + +**Figure 5.3.12.2-1: EXAMPLE of a deep neural network AI/ML model split across five inference** + +**REQ-SEC-AIML-12:** An O-RAN architecture element processing, storing or transferring AI/ML models may support the splitting of AI/ML models to enhance security and privacy. + +EXAMPLE: Figure 5.3.12.2-1 shows a drawing of an example inference process with a deep neural network AI/ML model split across five different inference hosts. + +**REQ-SEC-AIML-13:** Sanitization of input data before the data is used for AI/ML Models' training shall be supported. + +**REQ-SEC-AIML-14:** Selection of a reduced set of relevant features for the AI/ML Model training may be supported, to reduce the likelihood of attacks caused by feature manipulation. + +**REQ-SEC-AIML-15:** Feature scaling of input data such that AI/ML model classifications are less susceptible to small variations in the input data may be supported. + +**REQ-SEC-AIML-16:** The AI/ML training service Producer shall support the application of adversarial training to AI/ML Models to enable the Models to be robust. + +# 6 SBOM Guidelines for O-RAN + +## 6.1 SBOM Overview + +This clause provides guidance for generation, delivery, and use of a software bill of materials (SBOM). + +SBOM is a fundamental component of a mature Software Development Lifecycle (SDLC) process. SBOM is an industry best practice part of secure software development that enhances the understanding of the upstream software supply chain so that vulnerability notifications and updates can be properly and safely handled across the installed customer base. The U.S. Department of Commerce (DoC) and the National Telecommunications and Information Administration (NTIA) define SBOM as “a formal record containing the details and supply chain relationships of various components used in building software.” The DoC, in coordination with NTIA, published a report “The Minimum Elements for a Software Bill of Materials (SBOM)” [17] that provides guidance on the data fields, automation, and processes to be used by suppliers and customers. The SBOM documents proprietary and third-party software, including commercial and free and open-source software (FOSS), used in software products. The SBOM is maintained and used by the software supplier and stored and viewed by the network operator. + +## 6.2 + +[Intentionally blank] + +## 6.3 SBOM Requirements for O-RAN + +### 6.3.1 Requirements + +**REQ-SBOM-001:** The producer of O-RAN software shall create an SBOM for every O-RAN software package release. + +**REQ-SBOM-002:** The minimum set of data fields shall include Supplier Name, Component Name, Version of the Component, Other Unique Identifiers as available, Dependency Relationship, Author of the SBOM data, and Timestamp [17]. + +**REQ-SBOM-003:** Vulnerabilities shall not be included as an additional data field because it would represent a static view from a specific point in time, while vulnerabilities are constantly evolving. + +NOTE 1: The SBOM should be used by vendors and operators to periodically check against known vulnerability databases to identify potential risk. + +NOTE 2: The level of risk for a vulnerability should be determined by the software vendor and operator with consideration of the software product, use case, and network environment. + +NOTE 3: The SBOM provides visibility into the use of open-source and third-party provided software having known vulnerabilities or contributions from individuals or companies in adversarial nations, but it does not protect against zero-day vulnerabilities that were unintentionally or maliciously inserted, exploited, or discovered and not reported. + +**REQ-SBOM-004:** An SBOM shall contain all primary (top level) components, with top-level dependencies listed with enough detail to seek out the transitive dependencies recursively. + +**REQ-SBOM-005:** Void + +**REQ-SBOM-006:** Void + +**REQ-SBOM-007:** SBOM shall be authenticity and integrity protected. + +**REQ-SBOM-008:** Void + +**REQ-SBOM-009:** Void + +**REQ-SBOM-010:** Void + +**REQ-SBOM-011:** The SBOM shall be provided in Software Package Data eXchange (SPDX) [17], CycloneDX [18], or Software Identification (SWID) [19] format. + +NOTE 5: ISO/IEC 5962:2021[21] - Information technology — SPDX® Specification V2.2.1, published August 2021, specifies SPDX as a standard data format for communicating the component and metadata information associated with SBOM. + +### 6.3.2 Security Controls + +**SEC-CTL-SBOM-001:** The SBOM for an O-RAN software package shall use hashing and digital signing as defined in O-RAN Security Protocols Specifications [3], clause 5. + +**SEC-CTL-SBOM-002:** Void + +# --- Annex A (informative): Security Principles mapping to Security Requirements + +EDITOR'S NOTE: The table needs to be finished. + +Table A-1: Security Principles mapping to Security Requirements defined in [i.14]. + +| | Components | | | | | | | Interfaces | | | | | | +|-----------------------|--------------|--------------|--------------|------------------------------|----------------|----------------------|---------|-------------------|----------------|--------------------|----------------------|----|----------------------| +| SP | O-
    R
    U | O-
    D
    U | O-
    C
    U | O-
    CLOUD | Near RT
    RIC | Non
    RT
    RI
    C | SM
    O | FH
    M-
    Plane | FH S-
    Plane | FH
    CU-
    Plane | E2 | O1 | A1 | +| SP-
    AUTH
    | | | | REQ-
    SEC-
    OCLOUD
    -1 | | | | | | | | | | +| SP-ACC | | | | | | | | | | | | | | +| SP-
    CRYPTO
    | | | | | | | | | | | | | | +| SP-
    TCOMM
    | | | | | | | | | | | REQ-
    SEC-
    O2-1 | | REQ-
    SEC-
    A1-1 | +| SP-SS | | | | | | | | | | | | | | +| SP-SB | | | | | | | | | | | | | | +| SP-
    UPDT
    | | | | | | | | | | | | | | +| SP-
    RECO
    | | | | | | | | | | | | | | +| SP-
    OPNS
    | | | | | | | | | | | | | | +| SP-ASSU | | | | | | | | | | | | | | +| SP-PRV | | | | | | | | | | | | | | +| SP-SLC | | | | | | | | | | | | | | +| SP-ISO | | | | REQ-
    SEC-
    OCLOUD
    -2 | | | | | | | | | | +| SP-PHY | | | | | | | | | | | | | | +| SP-CLD | | | | | | | | | | | | | | +| SP-ROB | | | | | | | | | | | | | | + +# Annex B (informative): Security: List of 3GPP security requirements + +**Table B-1: References for 3GPP Security requirements** + +| Reference | Title | +|-----------|--------------------------------------------------------------------------------------------------------------------------| +| TS 33.501 | Security architecture and procedures for 5G system | +| TS 33.511 | Security Assurance Specification (SCAS) for the next generation - Node B (gNodeB) network product class | +| TS 33.117 | Catalogue of general security assurance requirements | +| TR 33.818 | Security Assurance Methodology (SECAM) and Security Assurance Specification (SCAS) for 3GPP virtualized network products | +| TR 33.848 | Study on security impacts of virtualization | + +**Table B-2: 3GPP Security requirements** + +| Item | Title | 3GPP Security requirements | 3GPP specifications | NESAS/SCAS | +|---------------------------------------------------------|----------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------|--------------------------| +| gNodeB-specific security functional requirements | | | | | +| #1 | Mitigation of bidding down attacks in Xn handovers | An attacker could attempt a bidding down attack by making the UE and the network entities respectively believe that the other side does not support a security feature, even when both sides in fact support that security feature. It shall be ensured that a bidding down attack, in the above sense, can be prevented.

    In the Path-Switch message, the target gNB shall send the UE's 5G security capabilities, UP security policy with corresponding PDU session ID received from the source gNB to the AMF. | TS 33.501
    §5.1.1 &
    §6.7.3.1 | TS 33.511
    §4.2.2.1.14 | +| #2 | Authentication and Authorization | Access network authorization: Assurance shall be provided to the UE that it is connected to an access network that is authorized by the serving network to provide services to the UE. This authorization is 'implicit' in the sense that it is implied by a successful establishment of access network security. This access network authorization applies to all types of access networks. | TS 33.501
    §5.1.2 | | +| #3 | Requirements on gNB related to keys | The gNB shall allow for use of encryption and integrity protection algorithms for AS (Access Stratum) and NAS (Non Access Stratum) protection having keys of length 128 bits. The network interfaces shall support the transport of 256-bit keys. The keys used for UP (User Plane), NAS and AS protection shall be dependent on the algorithm with which they are used. | TS 33.501
    §5.1.3 | | +| #4 | Subscriber privacy | The SUPI should not be transferred in clear text over gNB except routing information, e.g. Mobile Country Code (MCC) and Mobile Network Code (MNC). | TS 33.501
    §5.2.5 | | + +| | | | | | +|----|-----------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------|---------------------------------------------------------------------------| +| #5 | User data and signalling data confidentiality |

    The gNB shall support ciphering of user data between the UE and the gNB.

    The gNB shall activate ciphering of user data based on the security policy sent by the SMF.

    The gNB shall support ciphering of RRC-signalling.

    The gNB shall implement the following ciphering algorithms:

    • - NEA0, 128-NEA1, 128-NEA2 as defined in Annex D of 3GPP TS 33.501.

    The gNB may implement the following ciphering algorithm:

    • - 128-NEA3 as defined in Annex D of 3GPP TS 33.501.

    Confidentiality protection of user data between the UE and the gNB is optional to use.

    Confidentiality protection of the RRC-signalling is optional to use.

    Confidentiality protection should be used whenever regulations permit.

    The PDCP protocol, as specified in TS 38.323 between the UE and the NG-RAN, shall be responsible for user plane data confidentiality protection.

    | TS 33.501
    §5.3.2 | TS 33.511
    §4.2.2.1.6 &
    §4.2.2.1.7 &
    §4.2.2.1.10 &
    §4.2.2.1.11 | +| #6 | User data and signalling data integrity |

    The gNB shall support integrity protection and replay protection of user data between the UE and the gNB.

    The gNB shall activate integrity protection of user data based on the security policy sent by the SMF.

    The gNB shall support integrity protection and replay protection of RRC-signalling.

    The gNB shall support the following integrity protection algorithms:

    • - NIA0, 128-NIA1, 128-NIA2 as defined in Annex D of 3GPP TS 33.501.

    The gNB may support the following integrity protection algorithm:

    • - 128-NIA3 as defined in Annex D of 3GPP TS 33.501.

    Integrity protection of the user data between the UE and the gNB is optional to use, and shall not use NIA0.

    All RRC signalling messages except those explicitly listed in TS 38.331 as exceptions shall be integrity-protected with an integrity protection algorithm different from NIA0, except for unauthenticated emergency calls.

    NIA0 shall be disabled in gNB in the deployments where support of unauthenticated emergency session is not a regulatory requirement.

    The PDCP protocol, as specified in TS 38.323 between the UE and the NG-RAN, shall be responsible for user plane data integrity protection.

    | TS 33.501
    §5.3.3 | TS 33.511
    §4.2.2.1.1 &
    §4.2.2.1.2 &
    §4.2.2.1.8 &
    §4.2.2.1.9 | +| #7 | RRC integrity check failure |

    The RRC integrity checks shall be performed both in the ME and the gNB.

    In case failed integrity check (i.e. faulty or missing MAC-I) is detected after the start of integrity protection, the concerned message shall be discarded. This can happen on the gNB side or on the ME side.

    | TS 33.501
    §6.5.1 | | +| #8 | UP integrity check failure |

    If the gNB or the UE receives a PDCP PDU which fails integrity check with faulty or missing MAC-I after the start of integrity protection, the PDU shall be discarded.

    | TS 33.501
    §6.6.4 | | + +| | | | | | +|-----|----------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------|--| +| #9 | Requirements for the gNB setup and configuration |

    Setting up and configuring gNBs by O&M systems shall be authenticated and authorized by gNB so that attackers shall not be able to modify the gNB settings and software configurations via local or remote access.

    • - The certificate enrolment mechanism specified in TS 33.310 for base station should be supported for gNBs. The decision on whether to use the enrolment mechanism is left to operators.
    • - Communication between the O&M systems and the gNB shall be confidentiality, integrity and replay protected from unauthorized parties. The security associations between the gNB and an entity in the 5G Core or in an O&M domain trusted by the operator shall be supported. These security association establishments shall be mutually authenticated. The security associations shall be realized according to TS 33.210 and TS 33.310.
    • - The gNB shall be able to ensure that software/data change attempts are authorized.
    • - The gNB shall use authorized data/software.
    • - Sensitive parts of the boot-up process shall be executed with the help of the secure environment.
    • - Confidentiality of software transfer towards the gNB shall be ensured.
    • - Integrity protection of software transfer towards the gNB shall be ensured.
    • - The gNB software update shall be verified before its installation (cf. sub-clause 4.2.3.3.5 of TS 33.117).
    | TS 33.501
    §5.3.4 | | +| #10 | Requirements for key management inside the gNB | Any part of a gNB deployment that stores or processes keys in cleartext shall be protected from physical attacks. If not, the whole entity is placed in a physically secure location, then keys in cleartext shall be stored and processed in a secure environment. Keys stored inside a secure environment in any part of the gNB shall never leave the secure environment except when done in accordance with 3GPP specifications. | TS 33.501
    §5.3.5 | | +| #11 | Requirements for handling user plane data for the gNB | Any part of a gNB deployment that stores or processes user plane data in cleartext shall be protected from physical attacks. If not, the whole entity is placed in a physically secure location, then user plane data in cleartext shall be stored and processed in a secure environment. | TS 33.501
    §5.3.6 | | +| #12 | Requirements for handling control plane data for the gNB | Any part of a gNB deployment that stores or processes control plane data in cleartext shall be protected from physical attacks. If not, the whole entity is placed in a physically secure location, then control plane data in cleartext shall be stored and processed in a secure environment. | TS 33.501
    §5.3.7 | | +| #13 | Requirements for secure environment of the gNB |

    The secure environment shall support secure storage of sensitive data, e.g. long-term cryptographic secrets and vital configuration data.

    The secure environment shall support the execution of sensitive functions, e.g. en-/decryption of user data and the basic steps within protocols which use long term secrets (e.g. in authentication protocols).

    The secure environment shall support the execution of sensitive parts of the boot process.

    The secure environment's integrity shall be assured.

    Only authorised access shall be granted to the secure environment, i.e. to data stored and used within it, and to functions executed within it.

    | TS 33.501
    §5.3.8 | | + +| | | | | | +|-----|---------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------|-------------------------------------------| +| #14 | Requirements for the gNB F1 interfaces |

    F1-C interface shall support confidentiality, integrity, and replay protection.

    All management traffic carried over the CU-DU link shall be integrity, confidentiality and replay protected.

    The gNB shall support confidentiality, integrity and replay protection on the gNB DU-CU F1-U interface for user plane.

    F1-C and management traffic carried over the CU-DU link shall be protected independently from F1-U traffic.

    Security mechanisms

    In order to protect the traffic on the F1-U interface, IPsec ESP and IKEv2 certificates-based authentication shall be supported as specified in sub-clause 9.1.2 of 3GPP TS 33.501 with confidentiality, integrity and replay protection.

    In order to protect the traffic on the F1-C interface, IPsec ESP and IKEv2 certificates-based authentication shall be supported as specified in sub-clause 9.1.2 of 3GPP TS 33.501 with confidentiality, integrity, and replay protection.

    IPsec is mandatory to implement on the gNB-DU and on the gNB-CU. On the gNB-CU side, a SEG may be used to terminate the IPsec tunnel.

    In addition to IPsec, for the F1-C interface, DTLS shall be supported as specified in RFC 6083 to provide integrity protection, replay protection and confidentiality protection. Security profiles for DTLS implementation and usage shall follow the provisions given in clause 6.2 of TS 33.210.

    | TS 33.501
    §5.3.9 &
    §9.8.2 | | +| #15 | Requirements for the gNB E1 interfaces |

    The E1 interface between CU-CP and CU-UP shall be confidentiality, integrity and replay protected.

    Security mechanisms

    In order to protect the traffic on the E1 interface, IPsec ESP and IKEv2 certificates-based authentication shall be supported as specified in sub-clause 9.1.2 of 3GPP TS 33.501 with confidentiality, integrity, and replay protection.

    In addition to IPsec, DTLS shall be supported as specified in RFC 6083 to provide integrity protection, replay protection and confidentiality protection. Security profiles for DTLS implementation and usage shall follow the provisions given in clause 6.2 of TS 33.210.

    IPsec is mandatory to support on the gNB-CU-UP and the gNB-CU-CP. Observe that on both the gNB-CU-CP and the gNB-CU-UP sides, a SEG may be used to terminate the IPsec tunnel.

    | TS 33.501
    §5.3.10 &
    §9.8.3 | | +| #16 | Security mechanisms for the N2/Xn interface |

    The transport of control plane data and user data over Xn/N2 shall be integrity, confidentiality and replay-protected.

    Security mechanisms

    In order to protect the traffic on the Xn reference point, it is required to implement IPsec ESP and IKEv2 certificate-based authentication as specified in sub-clause 9.1.2 of 3GPP TS 33.501 with confidentiality, integrity, and replay protection. IPsec shall be supported on the gNB.

    In addition to IPsec, for the Xn-C interface, DTLS shall be supported as specified in RFC 6083 to provide integrity protection, replay protection and confidentiality protection. Security profiles for DTLS implementation and usage shall follow the provisions given in clause 6.2 of TS 33.210.

    | TS 33.501
    §9.2 & §9.4 | TS 33.511
    §4.2.2.1.16 &
    §4.2.2.1.17 | +| #17 | AS algorithms selection |

    The serving network shall select the algorithms to use dependent on: the UE security capabilities of the UE, the configured allowed list of security capabilities of the currently serving network entity.

    Each gNB shall be configured via network management with lists of algorithms which are allowed for usage. There shall be one list for integrity algorithms, and one for ciphering algorithms. These lists shall be ordered according to a priority decided by the operator.

    | TS 33.501
    §6.7.3.0 &
    §5.11.2 | TS 33.511
    §4.2.2.1.12 | + +| | | | | | +|-----|-------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------|----------------------------------------------------| +| #18 | Key refresh at the gNB |

    Key refresh shall be possible for KgNB, KRRC-enc, KRRC-int, KUP-int, and KUP-enc and shall be initiated by the gNB when a PDCP COUNTs are about to be re-used with the same Radio Bearer identity and with the same KgNB.

    The network is responsible for avoiding reuse of the COUNT with the same RB identity and with the same key, e.g. due to the transfer of large volumes of data, release and establishment of new RBs, and multiple termination point changes for RLC-UM bearers. In order to avoid such reuse, the network may e.g. use different RB identities for RB establishments, change the AS security key, or an RRC_CONNECTED to RRC_IDLE/RRC_INACTIVE and then to RRC_CONNECTED transition." as specified in TS 38.331 [6], clause 5.3.1.2.

    | TS 33.501
    §6.9.4.1
    TS 38.331
    §5.3.1.2 | TS 33.511
    §4.2.2.1.13 | +| #19 | AS protection algorithm selection in gNB change | The target gNB shall select the algorithm with highest priority from the UE's 5G security capabilities according to the locally configured prioritized list of algorithms (this applies for both integrity and ciphering algorithms). The chosen algorithms shall be indicated to the UE in the Handover Command message if the target gNB selects different algorithms compared to the source gNB. | TS 33.501
    §6.7.3.1 &
    §6.7.3.2 | TS 33.511
    §4.2.2.1.15 | +| #20 | Key update at the gNB on dual connectivity |

    When executing the procedure for adding subsequent radio bearer(s) to the same SN, the MN shall, for each new radio bearer, assign a radio bearer identity that has not previously been used since the last KSN change. If the MN cannot allocate an unused radio bearer identity for a new radio bearer in the SN, due to radio bearer identity space exhaustion, the MN shall increment the SN Counter and compute a fresh KSN, and then shall perform a SN Modification procedure to update the KSN.

    The SN shall request the Master Node to update the KSN over the Xn-C, when uplink and/or downlink PDCP COUNTs are about to wrap around for any of the SCG DRBs or SCG SRB.

    | TS 33.501
    §6.10.2.1 &
    §6.10.2.2.1 | TS 33.511
    §4.2.2.1.18 | +| #21 | Unauthorized Viewing | When the system is not under maintenance, there shall be no system function that reveals confidential system internal data in the clear to users and administrators. Such functions could be, for example, local or remote OAM CLI or GUI, logging messages, alarms, configuration file exports. Confidential system internal data contains authentication data (i.e. PINs, cryptographic keys, passwords, cookies) as well as system internal data that is not required for systems administration and could be of advantage to attackers (i.e. stack traces in error messages). | | TS 33.511
    §4.2.3.2.2
    TS 33.117
    §4.2.3.2.2 | +| #22 | Protecting data and information in storage |

    For sensitive data in (persistent or temporary) storage read access rights shall be restricted. Files of a system that are needed for the functionality shall be protected against manipulation.

    In addition, the following rules apply for:

    • - Systems that need access to identification and authentication data in the clear, e.g. in order to perform an authentication. Such systems shall not store this data in the clear, but scramble or encrypt it by implementation-specific means.
    • - Systems that do not need access to sensitive data (e.g. user passwords) in the clear. Such systems shall hash this sensitive data.
    • - Stored files on the network product: examples for protection against manipulation are the use of checksum or cryptographic methods.
    | | TS 33.511
    §4.2.3.2.3
    TS 33.117
    §4.2.3.2.3 | +| #23 | Protecting data and information in transfer |

    Usage of cryptographically protected network protocols is required.

    The transmission of data with a need of protection shall use industry standard network protocols with sufficient security measures and industry accepted algorithms. In particular, a protocol version without known vulnerabilities or a secure alternative shall be used.

    | | TS 33.511
    §4.2.3.2.4
    TS 33.117
    §4.2.3.2.4 | + +| | | | | | +|-----|------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--------------------------------------------------| +| #24 | System handling during overload situations |

    The system shall provide security measures to deal with overload situations which may occur as a result of a denial of service attack or during periods of increased traffic or reach the congestion threshold. In particular, partial, or complete impairment of system availability shall be avoided. Potential protective measures include:

    • - Restricting available RAM per application.
    • - Restricting maximum sessions for a Web application.
    • - Defining the maximum size of a dataset.
    • - Restricting CPU resources per process.
    • - Prioritizing processes.
    • - Overload control method, e.g. limiting amount or size of transactions of a user or from an IP address in a specific time range.
    | | TS 33.511
    §4.2.3.3
    TS 33.117
    §4.2.3.3.1 | +| #25 | Boot from intended memory devices only |

    The network product can boot only from the memory devices intended for this purpose.

    | | TS 33.511
    §4.2.3.3
    TS 33.117
    §4.2.3.3.2 | +| #26 | System handling during excessive overload situations |

    The system shall act in a predictable way if an overload situation cannot be prevented. A system shall be built in this way that it can react on an overload situation in a controlled way. However, it is possible that a situation happens where the security measures are no longer sufficient. In such case it shall be ensured that the system cannot reach an undefined and thus potentially insecure state. In an extreme case this means that a controlled system shutdown is preferable to uncontrolled failure of the security functions and thus loss of system protection. The vendor shall provide a technical description of the network product's Over Load Control mechanisms (especially whether these mechanisms rely on cooperation of other network elements e.g. eNode B) and the accompanying test case for this requirement will check that the description provides sufficient detail in order for an evaluator to understand how the mechanism is designed.

    | | TS 33.511
    §4.2.3.3
    TS 33.117
    §4.2.3.3.3 | +| #27 | System robustness against unexpected input |

    During transmission of data to a system it is necessary to validate input to the network product before processing. This includes all data which is sent to the system. Examples of this are user input, values in arrays and content in protocols. The following typical implementation error shall be avoided:

    • - No validation on the lengths of transferred data
    • - Incorrect assumptions about data formats
    • - No validation that received data complies with the specification
    • - Insufficient handling of protocol errors in received data
    • - Insufficient restriction on recursion when parsing complex data formats
    • - White listing or escaping for inputs outside the values margin
    | | TS 33.511
    §4.2.3.3
    TS 33.117
    §4.2.3.3.4 | +| #28 | Network product Software integrity validation |
    1. 1) Software package integrity shall be validated in the installation/upgrade stage.
    2. 2) Network product shall support software package integrity validation via cryptographic means, e.g. digital signature. To this end, the network product has a list of public keys or certificates of authorised software sources, and uses the keys to verify that the software update is originated from only these sources.
    3. 3) Tampered software shall not be executed or installed if integrity check fails.
    4. 4) A security mechanism is required to guarantee that only authorized individuals can initiate and deploy a software update, and modify the list mentioned in bullet 2.
    | | TS 33.511
    §4.2.3.3
    TS 33.117
    §4.2.3.3.5 | + +| | | | | | +|-----|----------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------------------------------------------------------| +| #29 | System functions shall not be used or accessed without successful authentication and authorization | The usage of a system function without successful authentication on basis of the user identity and at least one authentication attribute (e.g. password, certificate) shall be prevented. System functions comprise, for example network services (like SSH, SFTP, Web services), local access via a management console, local usage of operating system and applications. This requirement shall also be applied to accounts that are only used for communication between systems. An exception to the authentication and authorization requirement are functions for public use such as those for a Web server on the Internet, via which information is made available to the public. | | TS 33.117
    §4.2.3.4.1.1 | +| #30 | The network product shall use accounts that allow unambiguous identification of the user | Users shall be identified unambiguously by the network product. The network product shall support assignment of individual accounts per user, where a user could be a person, or, for Machine Accounts, an application, or a system. The network product shall not enable the use of group accounts or group credentials, or sharing of the same account between several users, by default. The network product shall support a minimum number of 50 individual accounts per user data base if not explicitly specified in a SCAS of a particular network product, so that accountability for each user is ensured even in large operator networks. The network product shall not support user access credentials unrelated to an account.

    NOTE: The network product may support independent user data bases for different access methods, e.g. one data base for command shell access on OS level and another data base for GUI access. User data bases may be stored locally on the network product or on a central AAA system that the network product accesses for user authentication. | | TS 33.117
    §4.2.3.4.1.2 | +| #31 | Account protection by at least one authentication attribute | The various user and machine accounts on a system shall be protected from misuse. To this end, an authentication attribute is typically used, which, when combined with the user name, enables unambiguous authentication and identification of the authorized user.
    Authentication attributes include:
    - Cryptographic keys
    - Token
    - Passwords
    This means that authentication based on a parameter that can be spoofed (e.g. phone numbers, public IP addresses or VPN membership) is not permitted. Exceptions are attributes that cannot be faked or spoofed by an attacker. | | TS 33.511
    §4.2.3.4.1
    TS 33.117
    §4.2.3.4.2.1 | +| #32 | Predefined accounts shall be deleted or disabled | All predefined or default accounts shall be deleted or disabled. Many systems have default accounts (e.g. guest, ctxsys), some of which are preconfigured with or without known passwords. These standard users shall be deleted or disabled. Should this measure not be possible the accounts shall be locked for remote login. In any case disabled or locked accounts shall be configured with a complex password as specified in clause 4.2.3.4.3.1 Password Structure of TS 33.117. This is necessary to prevent unauthorized use of such an account in case of misconfiguration. Exceptions to this requirement to delete or disable accounts are accounts that are used only internally on the system involved and that are required for one or more applications on the system to function. Also, for these accounts remote access or local login shall be forbidden to prevent abusive use by users of the system. | | TS 33.511
    §4.2.3.4.1
    TS 33.117
    §4.2.3.4.2.2 | +| #33 | Predefined or default authentication attributes shall be deleted or disabled | Normally, authentication attributes such as password or cryptographic keys will be preconfigured from producer, vendor, or developer of a system. Such authentication attributes shall be changed by automatically forcing a user to change it on 1st time login to the system or the vendor provides instructions on how to manually change it. | | TS 33.511
    §4.2.3.4.1
    TS 33.117
    §4.2.3.4.2.3 | + +| | | | | | +|-----|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|---------------------------| +| #34 | Password Complexity rule |

    The setting by the vendor shall be such that a network product shall only accept passwords that comply with the following complexity criteria:

    1) Absolute minimum length of 8 characters (shorter lengths shall be rejected by the network product). It shall not be possible setting this absolute minimum length to a lower value by configuration.

    2) Comprising at least three of the following categories:

    • - at least 1 uppercase character (A-Z)
    • - at least 1 lowercase character (a-z)
    • - at least 1 digit (0-9)
    • - at least 1 special character (e.g. @;!\$.)

    The network product shall use a default minimum length of 10 characters. The minimum length of characters in the passwords shall be configurable by the operator. The default minimum length is the value configured by the vendor before any operator-specific configuration has been applied. The special characters may be categorized in sets according to their Unicode category.

    The network product shall at least support passwords of a length of 64 characters or a length greater than 64 characters.

    If a central system is used for user authentication, password policy is performed on the central system and additional assurance shall be provided that the central system enforces the same password complexity rules as laid down for the local system in this subclause. If a central system is not used for user authentication, the assurance on password complexity rules shall be performed on the Network Product.

    When a user is changing a password or entering a new password, the system checks and ensures that it meets the password requirements.

    Above requirements shall be applicable for all passwords used (e.g. application-level, OS-level,.).

    | | TS 33.117
    §4.2.3.4.3.1 | +| #35 | Password changes |

    If a password is used as an authentication attribute, then the system shall offer a function that enables a user to change his password at any time.

    When an external centralized system for user authentication is used it is possible to redirect or implement this function on this system.

    Password change shall be enforced after initial login.

    The system shall enforce password change based on password management policy. In particular, the system shall enforce password expiry.

    Previously used passwords shall not be allowed up to a certain number (Password History).

    The number of disallowed previously used passwords shall be:

    • - Configurable;
    • - Greater than 0;
    • - And its default value shall be 3. This means that the network product shall store at least the three previously set passwords. The maximum number of passwords that the network product can store for each user is up to the manufacturer.

    When a password is about to expire a password expiry notification shall be provided to the user.

    Above requirements shall be applicable for all passwords used (e.g. application-level, OS-level.). An exception to this requirement is machine accounts.

    | | TS 33.117
    §4.2.3.4.3.2 | + +| | | | | | +|-----|-------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|---------------------------| +| #36 | Protection against brute force and dictionary attacks |

    If a password is used as an authentication attribute, a protection against brute force and dictionary attacks that hinder password guessing shall be implemented.

    Brute force and dictionary attacks aim to use automated guessing to ascertain passwords for user and machine accounts. Various measures or a combination of these measures can be taken to prevent this.

    The most commonly used protection measures are:

    1. 1) Using the timer delay (this delay could be the same or increased depending the operator's policy for each attempt, e.g. double the delay, or 5 minutes delay, or 10 minutes delay) for each newly entered password input following an incorrect entry ("tar pit").
    2. 2) Blocking an account following a specified number of incorrect attempts, refer to 4.2.3.4.5 of TS 33.117. However, it has to be taken into account that this solution needs a process for unlocking and an attacker can force this to deactivate accounts and make them unusable.
    3. 3) Using CAPTCHA to prevent automated attempts (often used for Web applications).
    4. 4) Using a password blacklist to prevent vulnerable passwords.

    NOTE: Password management and blacklist configuration may be done in a separate node that is different to the node under test, e.g. a SSO server or any other central credential manager.

    In order to achieve higher security, it is often meaningful to combine two or more of the measures named here. It is left to the vendor to select appropriate measures.

    Above requirements shall be applicable for all passwords used (e.g. application-level, OS-level.). An exception to this requirement is machine accounts.

    | | TS 33.117
    §4.2.3.4.3.3 | +| #37 | Hiding password display |

    The password shall not be displayed in such a way that it could be seen and misused by a casual local observer. Typically, the individual characters of the password are replaced by a character such as "*".

    Under certain circumstances it may be permissible for an individual character to be displayed briefly during input. Such a function is used, for example, on smartphones to make input easier. However, the entire password is never output to the display in plaintext.

    Above requirements shall be applicable for all passwords used (e.g. application-level, OS-level.). An exception to this requirement is machine accounts.

    | | TS 33.117
    §4.2.3.4.3.4 | +| #38 | Network Product Management and Maintenance interfaces |

    The network product management shall support mutual authentication mechanisms, the mutual authentication mechanism can rely on the protocol used for the interface itself or other means.

    | | TS 33.117
    §4.2.3.4.4.1 | +| #39 | Policy regarding consecutive failed login attempts |
    1. a) The maximum permissible number of consecutive failed user account login attempts should be configurable by the operator. The definition of the default value set at manufacturing time for maximum number of failed user account login attempts shall be less than or equal to 8, typically 5. After the maximum permissible number of consecutive failed user account login attempts is exceeded by a user there shall be a block delay in allowing the user to attempt login again. This block delay and also the capability to set period of the block delay, e.g. double the delay, or 5 minutes delay, or 10 minutes delay, after each login failure should be configurable by the operator. The default value set at manufacturing time for this delay shall be greater than or equal to 5 sec.
    2. b) If supported, infinite (permanent) locking of an account that has exceeded maximum permissible number of consecutive failed user account login attempts should also be possible via configuration, with the exception of administrative accounts which shall get only temporarily locked.
    | | TS 33.117
    §4.2.3.4.5 | + +| | | | | | +|-----|----------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--------------------------------------------------| +| #40 | Authorization policy |

    The authorizations for accounts and applications shall be reduced to the minimum required for the tasks they have to perform.

    Authorizations to a system shall be restricted to a level in which a user can only access data and use functions that he needs in the course of his work. Suitable authorizations shall also be assigned for access to files that are components of the operating system or of applications or that are generated by the same (e.g. configuration and logging files).

    Alongside access to data, execution of applications and components shall also take place with rights that are as low as possible. Applications should not be executed with administrator or system rights.

    | | TS 33.117
    §4.2.3.4.6.1 | +| #41 | Role-based access control |

    The network product shall support Role Based Access Control (RBAC). A role-based access control system uses a set of controls which determines how users interact with domains and resources. The domains could be Fault Management (FM), Performance Management (PM), System Admin. The RBAC system controls how users or groups of users are allowed access to the various domains and what type of operation they can perform, i.e. the specific operation command or command group (e.g. View, Modify, Execute).

    The network product supports RBAC, in particular, for OAM privilege management for network product Management and Maintenance, including authorization of the operation for configuration data and software via the network product console interface.

    | | TS 33.117
    §4.2.3.4.6.2 | +| #42 | Protecting sessions – logout function |

    The system shall have a function that allows a signed in user to logout at any time. All processes under the logged in user ID shall be terminated on log out. The network product shall be able to continue to operate without interactive sessions.

    Only for debugging purposes, processes under a logged in user ID may be allowed to continue to run after detaching the interactive session.

    | | TS 33.511
    §4.2.3.5
    TS 33.117
    §4.2.3.5.1 | +| #43 | Protecting sessions – inactivity timeout |

    An OAM user interactive session shall be terminated automatically after a specified period of inactivity. It shall be possible to configure an inactivity time-out period.

    NOTE: The kind of activity required to reset the timeout timer depends on the type of user session.

    | | TS 33.511
    §4.2.3.5
    TS 33.117
    §4.2.3.5.2 | +| #44 | Security event logging |

    Security events shall be logged together with a unique system reference (e.g. host name, IP or MAC address) and the exact time the incident occurred. For each security event, the log entry shall include user name and/or timestamp and/or performed action and/or result and/or length of session and/or values exceeded and/or value reached.

    IETF RFC 3871, clause 2.11.10 specifies the minimum set of security events. Each vendor shall document what security events the product logs so that it can be verified by testing.

    | | TS 33.511
    §4.2.3.6
    TS 33.117
    §4.2.3.6.1 | +| #45 | Log transfer to centralized storage |

    a) The Network Product shall support forwarding of security event logging data to an external system. Secure transport protocols in accordance with clause 4.2.3.2.4 of TS 33.117, shall be used.

    b) Log functions should support secure uploading of log files to a central location or to an external system for the Network Product that is logging.

    | | TS 33.511
    §4.2.3.6
    TS 33.117
    §4.2.3.6.2 | +| #46 | Protection of security event log files |

    The security event log shall be access controlled (file access rights) so only privileged users have access to the log files.

    | | TS 33.511
    §4.2.3.6
    TS 33.117
    §4.2.3.6.3 | +| #47 | Growing (dynamic) content shall not influence system functions |

    Growing or dynamic content (e.g. log files, uploads) shall not influence system functions. A file system that reaches its maximum capacity shall not stop a system from operating properly. Therefore, countermeasures shall be taken such as usage of dedicated filesystems, separated from main system functions, or quotas, or at least a file system monitoring to ensure that this scenario is avoided.

    | | TS 33.511
    §4.2.4
    TS 33.117
    §4.2.4.1.1.1 | + +| | | | | | +|-----|---------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--------------------------------------------------| +| #48 | Processing of ICMPv4 and ICMPv6 packets |

    Processing of ICMPv4 and ICMPv6 packets which are not required for operation shall be disabled on the network product. In particular, there are certain types of ICMPv4 and ICMPv6 that are not used in most networks, but represent a risk.

    ICMP message types which on receipt lead to responses or to configuration changes are not mentioned in this requirement, but they may be necessary to support relevant and specified networking features. Those must be documented.

    Certain ICMP types are generally permitted and do not need to be specifically documented. Those are marked as "Permitted" in below table.

    The network product shall not send certain ICMP types by default, but it may support the option to enable utilization of these types (e.g. for debugging).

    Echo Reply can be sent by default.

    In case of remote base station auto deployment, Router Advertisement can be processed.

    | | TS 33.511
    §4.2.4
    TS 33.117
    §4.2.4.1.1.2 | +| #49 | IP packets with unnecessary options or extension headers shall not be processed | IP packets with unnecessary options or extension headers shall not be processed. IP options and extension headers (e.g. source routing) are only required in exceptional cases. So, all packets with enabled IP options or extension headers shall be filtered. | | TS 33.511
    §4.2.4
    TS 33.117
    §4.2.4.1.1.3 | +| #50 | Authenticated Privilege Escalation only | There shall not be a privilege escalation method in interactive sessions (CLI or GUI) which allows a user to gain administrator/root privileges from another user account without re-authentication. Implementation example: Disable insecure privilege escalation methods so that users are required to (re-)login directly into the account with the required permissions. | | TS 33.511
    §4.2.4
    TS 33.117
    §4.2.4.1.2.1 | +| #51 | System account identification | Each system account in UNIX® shall have a unique UID. | | TS 33.511
    §4.2.4
    TS 33.117
    §4.2.4.2.2 | +| #52 | HTTPS | The communication between Web client and Web server shall be protected using TLS. The TLS profile defined in Annex E of TS 33.310 shall be followed with the following modifications: Cipher suites with NULL encryption shall not be supported | | TS 33.511
    §4.2.5
    TS 33.117
    §4.2.5.1 | +| #53 | Webserver logging |

    Access to the webserver shall be logged. The web server log shall contain the following information:

    • - Access timestamp
    • - Source (IP address)
    • - (Optional) Account (if known)
    • - (Optional) Attempted login name (if the associated account does not exist)
    • - Relevant fields in http request. The URL should be included whenever possible.
    • - Status code of web server response
    | | TS 33.511
    §4.2.5
    TS 33.117
    §4.2.5.2.1 | + +| | | | | | +|-----|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|----------------------------------------------------| +| #54 | User sessions |

    To protect user sessions the Network Product shall support the following session ID and session cookie requirements:

    1. 1. The session ID shall uniquely identify the user and distinguish the session from all other active sessions.
    2. 2. The session ID shall be unpredictable.
    3. 3. The session ID shall not contain sensitive information in clear text (e.g. account number, social security.).
    4. 4. In addition to the Session Idle Timeout (see clause 4.2.3.5.2 Protecting sessions – Inactivity timeout of TS 33.117), the Network Product shall automatically terminate sessions after a configurable maximum lifetime. This maximum lifetime defines the maximum session span. When the maximum lifetime expires, the session shall be closed, the session ID shall be deleted, and the user shall be forced to (re)authenticate in the web application and to establish a new session. The default value for this maximum lifetime shall be set to 8 hours.
    5. 5. Session ID's shall be regenerated for each new session (e.g. each time a user log in).
    6. 6. The session ID shall not be reused or renewed in subsequent sessions.
    7. 7. The Network Product shall not use persistent cookies to manage sessions but only session cookies. This means that neither the "expire" nor the "max-age" attribute shall be set in the cookies.
    8. 8. Where session cookies are used the attribute 'HttpOnly' shall be set to true.
    9. 9. Where session cookies are used the 'domain' attribute shall be set to ensure that the cookie can only be sent to the specified domain.
    10. 10. Where session cookies are used the 'path' attribute shall be set to ensure that the cookie can only be sent to the specified directory or sub-directory.
    11. 11. The Network Product shall not accept session identifiers from GET/POST variables.
    12. 12. The Network Product shall be configured to only accept server generated session ID's.
    | | TS 33.511
    §4.2.5
    TS 33.117
    §4.2.5.3 | +| #55 | HTTP input validation |

    The Network Product shall have a mechanism in place to ensure that web application inputs are not vulnerable to command injection or cross-site scripting attacks. The Network Product shall validate, filter, escape, and encode user-controllable input before it is placed in output that is used as a web page that is served to other users.

    | | TS 33.511
    §4.2.5
    TS 33.117
    §4.2.5.4 | +| #56 | Packet filtering |

    The Network Product shall provide a mechanism to filter incoming IP packets on any IP interface (see RFC 3871 for further information). In particular the Network Product shall provide a mechanism:

    1. 1) To filter incoming IP packets on any IP interface at Network Layer .and Transport Layer of the stack ISO/OSI.
    2. 2) To allow specified actions to be taken when a filter rule matches. In particular at least the following actions should be supported:
      1. a. Discard/Drop: the matching message is discarded; no subsequent rules are applied and no answer is sent back.
      2. b. Accept: the matching message is accepted.
      3. c. Account: the matching message is accounted for i.e. a counter for the rule is incremented. This action can be combined with the previous ones. This feature is useful to monitor traffic before its blocking.
    3. 3) To enable/disable for each rule the logging for Dropped packets, i.e. details on messages matching the rule for troubleshooting.
    4. 4) To filter on the basis of the value(s) of any portion of the protocol header.
    5. 5) To reset the accounting.
    6. 6) The Network Product shall provide a mechanism to disable/enable each defined rule.
    | | TS 33.511
    §4.2.6.2.1
    TS 33.117
    §4.2.6.2.1 | + +| | | | | | +|--------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|----------------------------------------------------| +| #57 | Manipulated packets that are sent to an address of the network device shall not lead to an impairment of availability |

    A network device shall be not affected in its availability or robustness by incoming packets, from other network element, that are manipulated or differing the norm. This means that appropriate packets shall be detected as invalid and be discarded. The process shall not be affecting the performance of the network device. This robustness shall be just as effective for a great mass of invalid packets as for individual or a small number of packets.

    Examples of such packets are:

    • - Mass-produced TCP packets with a set SYN flag to produce half-open TCP connections (SYN flooding attack).
    • - Packets with the same IP sender address and IP recipient address (Land attack).
    • - Mass-produced ICMP packets with the broadcast address of a network as target address (Smurf attack).
    • - Fragmented IP packets with overlapping offset fields (Teardrop attack).
    • - ICMP packets that are larger than the maximum permitted size (65,535 Bytes) of IPv4 packets (Ping-of-death attack).
    • - Uncorrelated reply packets (i.e. packets which cannot be correlated to any request).

    Sometimes the relevant behaviour of the network device will be configured. In other cases, the behaviour of the network device may only be verified by the relevant tests.

    | | TS 33.511
    §4.2.6.2.2
    TS 33.117
    §4.2.6.2.2 | +| #58 | GTP-U Filtering |

    The following capability is conditionally required:

    • - For each message of a GTP-U-based protocol, it shall be possible to check whether the sender of this message is authorized to send a message pertaining to this protocol.

    NOTE: The check could be performed e.g. against a whitelist or blacklist of permitted message type / sender identity combinations.

    • - At least the following actions should be supported when the check is satisfied:
    • - Discard: the matching message is discarded.
    • - Accept: the matching message is accepted.
    • - Account: the matching message is accounted for, i.e. a counter for the rule is incremented. This action can be combined with the previous ones.

    This feature is useful to monitor traffic before its blocking.

    This requirement is conditional in the following sense: It is required that at least one of the following two statements holds:

    • - The Network Product supports the capability described above and this is stated in the product documentation.
    • - The Network Product's product documentation states that the capability is not supported and that the Network Product needs to be deployed together with a separate entity which provides the capability described above.

    NOTE : Such a separate entity could e.g. be a GTP Firewall.

    NOTE: Test cases for this separate entity are not provided in the present document, but are believed to be similar to them.

    NOTE: The test cases are only applicable to all network product classes utilizing GTP-U based protocol.

    | | TS 33.511
    §4.2.6.2.4
    TS 33.117
    §4.2.6.2.4 | +| gNodeB-specific security hardening requirements | | | | | +| Technical Baseline | | | | | +| #59 | No unnecessary or insecure services / protocols | The network product shall only run protocol handlers and services which are needed for its operation, and which do not have any known security vulnerabilities. | | TS 33.117
    §4.3.2.1 | +| #60 | Restricted reachability of services | The network product shall restrict the reachability of services so that they can only be reached on interfaces where their usage is required. On interfaces where services are active, the reachability should be limited to legitimate communication peers. | | TS 33.117
    §4.3.2.2 | + +| | | | | | +|--------------------------|------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|-------------------------| +| #61 | No unused software | Unused software components or parts of software which are not needed for operation or functionality of the network product shall not be installed or shall be deleted after installation. | | TS 33.117
    §4.3.2.3 | +| #62 | No unused functions | During installation of software and hardware often functions will be activated that are not required for operation or function of the system. Also, hardware functions which are not required for operation or function of the system (e.g. unused interfaces) shall be permanently deactivated. Permanently means that they shall not be reactivated again after network product reboot.
    EXAMPLE: A debugging function in software which can be used for troubleshooting shall not be activated during normal operation of the network product. | | TS 33.117
    §4.3.2.4 | +| #63 | No unsupported components | The network product shall not contain software and hardware components that are no longer supported by their vendor, producer, or developer, such as components that have reached end-of-life or end-of-support. Excluded are components that have a special support contract. This contract shall guarantee the correction of vulnerabilities over components' lifetime. | | TS 33.117
    §4.3.2.5 | +| #64 | Remote login restrictions for privileged users | Direct login as root or equivalent highest privileged user shall be limited to the system console only. Root user will not be allowed to login to the system remotely. | | TS 33.117
    §4.3.2.6 | +| #65 | Filesystem Authorization privileges | The system shall be designed to ensure that only users that are authorized to modify files, data, directories, or file systems have the necessary privileges to do so.
    EXAMPLE: On unix® systems a 'sticky' bit may be set on all directories where all users have written permissions. This ensures that only the file's owner, the directory's owner, or root user can rename or delete the file. Without the sticky bit being set, any user that has write and execute permissions for the directory can rename or delete files within the directory, regardless of the file's owner. | | TS 33.117
    §4.3.2.7 | +| Operating Systems | | | | | +| #66 | IP-Source address spoofing mitigation | Systems shall not process IP packets if their source address is not reachable via the incoming interface. Implementation example: Use of "Reverse Path Filter" (RPF) provides this function. | | TS 33.117
    §4.3.3.1.1 | +| #67 | Minimized kernel network functions | Kernel based network functions not needed for the operation of the network element shall be deactivated.
    In particular the following ones shall be disabled by default:
    - IP Packet Forwarding between different interfaces of the network product. | | TS 33.117
    §4.3.3.1.2 | +| #68 | No automatic launch of removable media | The network product shall not automatically launch any application when removable media device such as CD-, DVD-, USB-Sticks or USB-Storage drive is connected. If the operating system supports an automatic launch, it shall be deactivated unless it is required to support availability requirements. | | TS 33.117
    §4.3.3.1.3 | +| #69 | Syn Flood Prevention | The network product shall support a mechanism to prevent Syn Flood attacks (e.g. implement the TCP Syn Cookie technique in the TCP stack by setting net.ipv4.tcp_syncookies = 1 in the linux sysctl.conf file). This feature shall be enabled by default. | | TS 33.117
    §4.3.3.1.4 | +| #70 | Protection mechanisms against buffer overflows | The system shall support mechanisms for buffer overflow protection. Documentation which describes these buffer overflow mechanisms and also how to check that they have been enabled and/or implemented shall be provided. | | TS 33.117
    §4.3.3.1.5 | + +| | | | | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|-------------------------| +| #71 | External file system mount restrictions | If normal users are allowed to mount external file systems (attached locally or via the network), OS-level restrictions shall be set properly in order to prevent privilege escalation or extended access permissions due to the contents of the mounted file systems.
    Implementation example: In Linux® systems, administrators shall set the options nodev and nosuid in the /etc/fstab for all filesystems, which also have the "user" option. | | TS 33.117
    §4.3.3.1.6 | +| Web Servers | | | | | +| #72 | No system privileges for web server | No web server processes shall run with system privileges. This is best achieved if the web server runs under an account that has minimum privileges. If a process is started by a user with system privileges, execution shall be transferred to a different user without system privileges after the start. | | TS 33.117
    §4.3.4.2 | +| #73 | Unused HTTP methods shall be deactivated | HTTP methods that are not required shall be deactivated. Standard requests to web servers only use GET, HEAD, and POST. If other methods are required, they shall not introduce security leaks such as TRACK or TRACE. | | TS 33.117
    §4.3.4.3 | +| #74 | Any add-ons and components that are not required shall be deactivated | All optional add-ons and components of the web server shall be deactivated if they are not required. In particular, CGI or other scripting components, Server Side Includes (SSI), and WebDAV shall be deactivated if they are not required. | | TS 33.117
    §4.3.4.4 | +| #75 | No compiler, interpreter, or shell via CGI or other server-side scripting | If CGI (Common Gateway Interface) or other scripting technology is used, the CGI directory - or other corresponding scripting directory - shall not include compilers or interpreters (e.g. PERL interpreter, PHP interpreter/compiler, Tcl interpreter/compiler or operating system shells). | | TS 33.117
    §4.3.4.5 | +| #76 | No CGI or other scripting for uploads | If CGI or other scripting technology is used, the associated CGI/script directory shall not be used for uploads. | | TS 33.117
    §4.3.4.6 | +| #77 | No execution of system commands with SSI | If Server Side Includes (SSI) is active, the execution of system commands shall be deactivated. | | TS 33.117
    §4.3.4.7 | +| #78 | Access rights for web server configuration files shall only be granted to the owner of the web server process or to a user with system privileges | Access rights for web server configuration files shall only be granted to the owner of the web server process or to a user with system privileges. Implementation example: Delete "read" and "write" access rights for "others." Only grant "write" access to the user who configures the web server. | | TS 33.117
    §4.3.4.8 | +| #79 | Default content shall be removed | Default content (examples, help files, documentation, aliases) that is provided with the standard installation of the web server shall be removed. | | TS 33.117
    §4.3.4.9 | +| #80 | No directory listings / Directory Browsing | Directory listings (indexing) / "Directory browsing" shall be deactivated. | | TS 33.117
    §4.3.4.10 | +| #81 | Information about the web server in HTTP headers shall be minimized | The HTTP header shall not include information on the version of the web server and the modules/add-ons used. | | TS 33.117
    §4.3.4.11 | + +| | | | | | +|-------------------------------------------------|-------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|-------------------------------------------------------| +| #82 | Web server information in error pages shall be deleted | User-defined error pages shall not include version information about the web server and the modules/add-ons used. Error messages shall not include internal information such as internal server names, error codes. Default error pages of the web server shall be replaced by error pages defined by the vendor. | | TS 33.117
    §4.3.4.12 | +| #83 | File type- or script-mappings that are not required shall be deleted | File type- or script-mappings that are not required shall be deleted, e.g. php, phtml, js, sh, csh, bin, exe, pl, vbe, vbs. | | TS 33.117
    §4.3.4.13 | +| #84 | The web server shall only deliver files which are meant to be delivered | Restrictive access rights shall be assigned to all files which are directly or indirectly (e.g. via links or in virtual directories) in the web server's document directory. In particular, the web server shall not be able to access files which are not meant to be delivered. | | TS 33.117
    §4.3.4.14 | +| #85 | Only execute rights in CGI/Scripting directory | If CGI or other scripting technology is used, only the CGI/Scripting directory is configured with execute rights. Other directories used or meant for web content do not have execute rights. | | TS 33.117
    §4.3.4.15 | +| Network Devices | | | | | +| #86 | Traffic Separation | The network product shall support physical or logical separation of traffic belonging to different network domains. For example, O&M traffic and control plane traffic belong to different network domains. See RFC 3871 for further information. | | TS 33.117
    §4.3.5.1 | +| Basic vulnerability testing requirements | | | | | +| #87 | Port scanning | It shall be ensured that on all network interfaces, only documented ports on the transport layer respond to requests from outside the system. | | TS 33.117
    §4.4.2 | +| #88 | Vulnerability scanning | The purpose of vulnerability scanning is to ensure that there are no known vulnerabilities (or that relevant vulnerabilities are identified and remediation plans in place to mitigate them) on the Network Product, both in the OS and in the applications installed, that can be detected by means of automatic testing tools via the Internet Protocol enabled network interfaces.
    Vulnerability scanning tools may also report false positives and they shall be investigated and documented in the test report. | | TS 33.117
    §4.4.3 | +| #89 | Robustness and fuzz testing | It shall be ensured that externally reachable services are reasonably robust when receiving unexpected input. | | TS 33.117
    §4.4.4 | +| Virtualization | | | | | +| #90 | VNF package and VNF image integrity | 1) VNF package and image shall contain integrity validation value (e.g. MAC).
    2) VNF package shall be integrity protected during onboarding and its integrity shall be validated by the NFVO. | | TR 33.818
    §5.2.5.5.3.3.5.1
    TR 33.848
    §5.18.3 | +| #91 | GVNP lifecycle management security | 1) VNF shall authenticate VNFM when VNFM initiates a communication to VNF.
    2) VNF shall be able to establish securely protected connection with the VNFM.
    3) VNF shall check whether VNFM has been authorized when VNFM access VNF's API.
    4) VNF shall log VNFM's management operations for auditing. | | TR 33.818
    §5.2.5.5.7.1 | +| #92 | Secure executive environment provision | The VNF shall support to compare the owned resource state with the parsed resource state from VNFD (VNF Description) by the VNFM. The VNF can query the parsed resource state by the VNFM from the OAM. The VNF shall send an alarm to the OAM if the two resource states are inconsistent. This comparing process can be triggered periodically by the VNF, or the administrator can manually trigger the VNF to perform the comparing process. | | TR 33.818
    §5.2.5.5.7.2 | + +| | | | | | +|------|-------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------------------------------------------------------| +| #93 | Traffic Separation | The virtualised network product shall support logical separation of traffic belonging to different network domains. For example, O&M traffic and control plane traffic belong to different network domains. See RFC 3871 for further information. | | TR 33.818
    §5.2.5.5.8.5.1
    TS 33.117
    §4.3.5.1 | +| #94 | Inter-VNF and intra-VNF Traffic Separation | The network used for the communication between the VNFCs of a VNF (intra-VNF traffic) and the network used for the communication between VNFCs (inter-VNF traffic) shall be separated to prevent the security threats from the different networks affect each other. | | TR 33.818
    §5.2.5.5.8.5.2 | +| #95 | Instantiating VNF from trusted VNF image | A VNF shall be initiated from a trusted VNF image which includes one or more than one images. The VNF image shall be signed by an authorized party. The authorized party is trusted by the operators. | | TR 33.818
    §5.2.5.6.6.1
    TR 33.848
    §5.18.3 | +| #96 | Secure virtualisation resource management | To prevent a compromised VIM from changing the assigned virtualised resource, the VNF shall alert to the OAM. For example, when an instantiated VNF is running, a compromised VIM can delete a VM which is running VNFC, the VNF shall alert to the OAM when the VNF cannot detect a VNFC message.
    A VNF shall log the access from the VIM.
    NOTE: The VIM manages the virtualisation resource assignment and synchronization of virtualised resource state information. In the implementation, the VIM and the virtualisation layer are coupled and provided by one vendor, they trust each other. Whether the VIM is trust or not is based on operator's decision. | | TR 33.818
    §5.2.5.6.7.1 | +| #97 | Secure executive environment creation | When an attacker tampers a driver which provided by the hardware and used to create the executive environment, the virtualisation layer shall alert the driver error to the administrator for checking the error and finding the attack at latter.
    NOTE: Whether the hardware is trust or not is based on operator's decision to ensure the virtualisation layer and the VNF to be run on the trusted hardware. | | TR 33.818
    §5.2.5.6.7.2 | +| #98 | VM escape protection | To defence the attack that an attacker utilizes a vulnerability of a VNF to attack a virtualisation layer and then control the virtualisation layer, the virtualisation layer shall implement the following requirements:
    The virtualisation shall reject the abnormal access from the VNF (e.g. the VNF accesses the memory which is not allocated to the VNF) and log the attacks. | | TR 33.818
    §5.2.5.6.7.3 | +| #99 | Secure hardware resource management | The VIM manages the hardware resource configuration and state information exchange. When the VIM is compromised to change the hardware resource configuration, an alert shall be triggered by the hardware. The administrator can check the alert and find the attack at latter. | | TR 33.818
    §5.2.5.7.7.1 | +| #100 | Secure hardware resource management information | When a compromised Virtualisation layer tampers the hardware resource configuration which is received from the VIM to result in the configuration error of the hardware, the hardware shall trigger an alert. The administrator can check the alert and find the attack at latter.
    NOTE: Whether the virtualisation layer is trust or not is based on operator's decision. | | TR 33.818
    §5.2.5.7.7.2 | +| #101 | Trusted platform | The host system shall implement a Hardware-Based Root of Trust (HBRT) ((e.g. TPM, HSM)) as Initial Root of Trust 1 . The trust state of the platform shall be measured and a trusted chain shall be built 2 . | | TR 33.818
    §5.2.5.7.7.3 | + +1 ETSI GS NFV-SEC 012: "Network Functions Virtualisation (NFV) Release 3; Security; System architecture specification for execution of sensitive NFV components". + +2 ETSI GR NFV-SEC 007: "Functions Virtualisation (NFV); Trust; Report on Attestation Technologies and Practices for Secure Deployments". + + + +# Annex C (informative): Guidance on Security Requirements & Controls + +## C.1 O-Cloud + +Controls given in this clause are designed as a guidance and non-normative. The implementation of those non-normative controls depends on the security policies within the O-Cloud Service Provider, O-RAN Application Provider and Service Provider. + +### C.1.1 Secure protection of cryptographic keys and sensitive data + +#### Potential solutions for SEC-CTL-OCLOUD-SS-1 + +The following potential implementation options for encrypting cryptographic keys and sensitive data within the O-Cloud platform could be used. The appropriate option to be used depends on the sensitivity of the data to be protected and needs to be assessed/determined by the Service provider. + +1. Software based: + - a. Software-based KMS vaults supporting management of keys, including creation, rotation, and revocation, as well as encrypting and decrypting sensitive data with managed keys [51]. + - b. Use a vTPM: A virtual Trusted Platform Module (vTPM) is a software-based representation of a physical Trusted Platform Module 2.0 chip to provide secure storage of credentials or keys [54]. A vTPM acts as any other virtual device. It performs the same functions as a TPM, but it performs cryptographic coprocessor capabilities in software. It should comply with the TPM 2.0 specification [53]. +2. Hardware based + - a. Hardware-based key vaults: The use of Key Management Service (KMS) based on an HSM [i.5], [i.6], [52]. The data is encrypted using a data encryption key (DEK); a new DEK is generated for each encryption. The DEKs are encrypted with a key encryption key (KEK) that is stored and managed in the HSM of the KMS provider. + - b. A hardware TPM [i.8], [53]. For data encryption, an encryption key is stored on disk but encrypted with the TPM master key (the storage root key (SRK)). This encryption key can only be used after it was decrypted by an authenticated TPM. The actual data encryption/decryption is then done by the main CPU, only decryption/encryption of the encryption key is done inside the TPM. + +#### Potential solutions for SEC-CTL-OCLOUD-SS-2 + +- Overwriting with zero (e.g., /dev/zero) or simple patterns. +- Overwriting with random data using: + - True random data source (e.g., /dev/random). This solution takes too long to wait for the entropy generation. + - Pseudorandom data source (e.g., /dev/urandom) can be used as a reasonable source of pseudorandom data. + +#### Potential solutions for SEC-CTL-OCLOUD-SS-3 + +Each data centre adheres to a strict disposal policy and uses the techniques described to achieve compliance with NIST SP 800-88 Revision 1 "Guidelines for Media Sanitization" [75] and DoD 5220.22-M "National Industrial Security Program Operating Manual" [50]. + +#### Potential solutions for REQ-SEC-OCLOUD-SS-5 + +Automatic memory scrubbing on boot: + +- Implement a process that automatically clears all volatile memory as early as possible during the boot sequence. This can be achieved through BIOS settings or early-stage boot loader scripts that overwrite memory with zeros or random data to ensure no residual data is left accessible. + +Watchdog timers: + +- Use timers that watch for unexpected shutdowns or power losses. If something goes wrong, these timers help make sure memory is cleaned properly before the system starts up again. + +Work with power backup systems: + +- For systems with an uninterruptible power supply (UPS), integrate the memory scrubbing mechanism with UPS software to initiate secure shutdown procedures that include clearing volatile memory when the UPS detects a power outage and is about to run out of battery. + +### C.1.2 Chain of Trust + +#### Potential solutions for SEC-CTL-OCLOUD-COT-1 + +There are many ways to measure platform integrity. In many cases, a hardware security module is used to store measurement data such as an HSM and TPM. Various platform integrity technologies build their own CoTs [i.7] and listed here below: + +- UEFI Secure Boot (SB) +- Intel Trusted Execution Technology (TXT) +- Intel Boot Guard +- Intel Platform Firmware Resilience (PFR) +- Intel Technology Example Summary +- AMD Platform Secure Boot (AMD PSB) +- Arm TrustZone Trusted Execution Environment (TEE) for Armv8-A +- Arm Secure Boot and the Chain of Trust (CoT) +- Cisco Platform Roots of Trust +- IBM Chain of Trust (CoT) + +For more details, see [i.7], clause 3.2. + +#### Potential solutions for SEC-CTL-OCLOUD-COT-2 + +A vTPM can be considered a software-based implementation of a root of trust. It emulates the behavior and functionalities of a physical TPM through software mechanisms and cryptographic libraries [53] and [54]. A vTPM operates within a virtual machine or as a software module within an operating system, leveraging the underlying hardware and security features provided by the host system. It can perform key generation, storage, and cryptographic operations similar to a physical TPM. However, since it is implemented in software, its security relies on the host system's security measures and may be more vulnerable to compromise if the host system is compromised. Therefore, it is crucial to ensure the overall security of the O-Cloud where the vTPM is deployed and to consider additional security measures to protect the software root of trust. + +#### Potential solutions for SEC-CTL-OCLOUD-COT-3 + +Please refer to the following technology examples in [i.7], clause 6.1 for more information: + +- Intel Security Libraries for the Data Center (ISecL-DC) +- Remote AS - Project Veraison (VERificAtion of atteStation) +- IBM Platform Attestation Tooling + +Relevant information on the Attestation Server is provided in [i.7], clause 6.1 and [i.15], clause 6.6. + +The following figure C.1.2-1 shows an example of remote AS: + +![Figure C.1.2-1: Example of Remote AS. The diagram illustrates the attestation process between an Attestation Server (AS) and the O-Cloud Platform. The O-Cloud Platform is divided into two main sections: 'O-RAN Apps/VNFs/CNFs' and 'O-Cloud Platform'. The 'O-Cloud Platform' section includes 'Virtual resources' (vRoT), 'Virtualization layer (Hypervisor/Container Engine)', and 'Hardware resources' (RoT). The 'O-RAN Apps/VNFs/CNFs' section includes a 'Virtual instance (VM/Container)' containing an 'App/VNF/CNF'. The process is numbered 1 through 4: 1. The trust agent (Trust Agent) periodically collects measurements from the RoT. 2. The virtualization layer provides the virtual resource (vRoT) to the virtual instance. 3. The virtual instance measures the App/VNF/CNF. 4. The AS verifies the collected measurements against trust policies. The AS is located outside the O-Cloud Platform, and its role is described as 'Could be within the SMO'.](16f9489ec205fb5077d6f2c57518cadd_img.jpg) + +Figure C.1.2-1: Example of Remote AS. The diagram illustrates the attestation process between an Attestation Server (AS) and the O-Cloud Platform. The O-Cloud Platform is divided into two main sections: 'O-RAN Apps/VNFs/CNFs' and 'O-Cloud Platform'. The 'O-Cloud Platform' section includes 'Virtual resources' (vRoT), 'Virtualization layer (Hypervisor/Container Engine)', and 'Hardware resources' (RoT). The 'O-RAN Apps/VNFs/CNFs' section includes a 'Virtual instance (VM/Container)' containing an 'App/VNF/CNF'. The process is numbered 1 through 4: 1. The trust agent (Trust Agent) periodically collects measurements from the RoT. 2. The virtualization layer provides the virtual resource (vRoT) to the virtual instance. 3. The virtual instance measures the App/VNF/CNF. 4. The AS verifies the collected measurements against trust policies. The AS is located outside the O-Cloud Platform, and its role is described as 'Could be within the SMO'. + +Figure C.1.2-1: Example of Remote AS + +The AS from the hardware layer to the O-RAN Application includes the following steps (see figure C.1.2-1): + +#### Attestation of the O-Cloud platform + +1. RoT measures and verifies hardware resources (server platform) including firmware/BIOS. It then launches the hardware resources. +2. The server act as the attester of the OS/virtualization layer. It measures, verifies, and launches the OS/virtualization layer. + +The attestation results and corresponding measurements are maintained by the management platform (e.g. Kubernetes) acting as the trust agent. + +#### Attestation of Application + +The attestation process is initiated by the management platform requesting to instantiate a new Application: + +3. The virtualization layer verifies the virtual instance. +4. Virtualized RoT (vRoT) measures the Application. The vRoT is a virtual instance associated to the hardware protected RoT. The virtualization layer provides this virtual resource to the virtual instance. + +Corresponding measurements are reported to the trust agent. The trust agent exposes the attestation results to authorized attestation server (could be within the SMO) so that it verifies collected measurements against trust policies already defined by administrators. + +### C.1.3 Recommended Security Policies + +| Requirements | Kubernetes admission controllers | Why | +|---------------------------------------------------------------------------|----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REQ-SEC-OCLOUD-SECPOL-1 | ImagePolicyWebhook | The ImagePolicyWebhook admission controller allows a backend webhook to make admission decisions based on the images being used. This can be configured to enforce policies regarding which image sources are allowed, ensuring that only images from approved sources can be deployed | +| REQ-SEC-OCLOUD-SECPOL-2 | ResourceQuota | The ResourceQuota admission controller is designed to enforce constraints on the amount of resources that can be consumed by objects in a Kubernetes namespace. | +| REQ-SEC-OCLOUD-SECPOL-3, REQ-SEC-OCLOUD-SECPOL-4, REQ-SEC-OCLOUD-SECPOL-5 | Pod Security Admission (PSA) | The Pod Security Admission (PSA) ensures that Pods meet the required security context and comply with the Pod Security Standards ( https://kubernetes.io/docs/concepts/security/pod-security-standards/ ) defined for the namespace they are in. | +| REQ-SEC-OCLOUD-SECPOL-6 | AlwaysPullImages | AlwaysPullImages forces every new pod to pull the required images every time. In a multi-tenant cluster users can be assured that their private images can only be used by those who have the credentials to pull them. Without this admission control policy, once an image has been pulled to a node, any pod from any user can use it simply by knowing the image's name, without any authorization check against the image ownership. When this plug-in is | + +| | | | +|-------------------------|-----------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | enabled, images are always pulled prior to starting containers, which means valid credentials are required. | +| REQ-SEC-OCLOUD-SECPOL-7 | DenyServiceExternalIPs, NetworkPolicies | NetworkPolicies allow to define rules governing how pods communicate with each other and with other network endpoints. These rules can specify what ingress (incoming) and egress (outgoing) traffic is allowed to and from a pod. DenyServiceExternalIPs admission controller can be used to prevent services from being exposed to the public internet via external IPs. NetworkPolicies allow to control egress/ingress traffic, ensuring that Pods can only communicate with approved, external IP ranges. | +| REQ-SEC-OCLOUD-SECPOL-8 | PodTolerationRestriction | The PodTolerationRestriction admission controller ensures that pods are scheduled only on nodes that meet specific criteria defined by taints and tolerations. Taints are applied to nodes, and tolerations are set on pods to allow or prevent them from being scheduled on certain nodes. | + +## C.2 Common Application Lifecycle Management + +### C.2.1 Software Package Protection + +#### Potential controls on REQ-SEC-ALM-PKG-1 and REQ-SEC-ALM-PKG-4 + +Application packages need to be frequently tested throughout the lifecycle of the Application: + +**Table C.2.1-1: Application Testing throughout the lifecycle** + +| During Development | During on-boarding and during instantiation | During Runtime | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +|

    Vulnerability scanning

    Static Application Security Testing (SAST)

    Dynamic Application Security testing (DAST)

    Penetration testing

    Software composition analysis

    Testing to be performed frequently for vulnerability scanning or misconfiguration on Application packages.

    EXAMPLE: To check for malware or secrets stored in package.

    Responsible: Application Provider

    |

    Vulnerability scanning

    Dynamic Application Security testing (DAST) to be performed for:

    • • Certifying the Application for functionality as well as authenticity, integrity, and packaging compliance.
    • • Blocking deployments if the package doesn't comply with the Service Provider security policies
    • • For scanning and detecting potential vulnerabilities
    • • Checking for malware
    • • Scanning for unnecessary system tools and libraries not required by Application
    • • Software composition analysis

    Responsible: Application Provider, Service Provider

    |

    Perform continuous scanning/monitoring for known vulnerability or misconfiguration on runtime workloads, check for any open ports, VM/Container escape.

    Responsible: Service Provider

    | + +Tools used for static code and dynamic security analysis, analysis of code being released, and penetration test results must be shared with the Service Provider. + +## C.3 Certificate Management Framework + +### C.3.1 Certificate enrolment for NF Deployment + +#### Potential solutions for SEC-CTL-CMF-VNF\_CNF-1 + +Table C.3.1-1 and Figure C.3.1-2 illustrate the steps performed to configure a certificate for NF Deployment. The certificate is used for secured communication between SMO and Cloudified NF. The below procedure is specified as an addition to the NF Deployment instantiation use case on O-Cloud as specified in clause 3.2.1 of ORAN TS Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN [82]. + +Table C.3.1-1: Certificate enrolment for NF Deployment + +| Use case stage | Evolution / specification | <> Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------| +| Goal | Initial configuration and certificate enrolment for NF Deployment instance | | +| Actors and Roles |

    Network Function Install Project Manager: Operator designing each Network Function instance [82];

    SMO: A Service Management and Orchestration framework [2].

    NFO: Network Function Orchestration [2].

    Operator PKI: Operator Public Key infrastructure.

    O-Cloud: Cloud platform that provides O-RAN standardized interfaces, hosting O-RAN defined software components [82].

    Cloudified NF: A RAN Network Function software that is deployed in the O-Cloud via one or more NF Deployments [82].

    NF Deployment: A software deployment on O-Cloud resources that realizes all or part of a Cloudified NF [82].

    End Entity: user of PKI certificates and/or end user system that is the subject of a certificate [81];

    | | +| Assumptions |

    NF : O-RAN Cloudified Network Functions (i.e., Near-RT RIC, O-CU-CP, O-CU-UP and O-DU), as specified in [2];

    NF instance secrets are shared in secured way before actual NF Deployment starts.

    | | +| Pre-conditions |

    i. Operator PKI is configured to issue a certificate to the NF Deployment instance.

    ii. All associated trust domains are created in PKI.

    | | +| Begins when | NF is ready for deployment. | | +| Step 1 (M) | Network Function Install Project Manager requests to SMO to instantiate NF Deployment on the O-Cloud. | | +| Step 2 (M) | NFO requests Operator PKI via the vendor specific PKI interface to create enrolment data for NF Deployment instance. | | +| Step 3(M) |

    Operator PKI responds with enrolment data to NFO.

    Enrolment data consists of: CMP details associated with provisioned End Entity as Cloudified NF, including Initial Authentication Key (IAK) and reference value as defined in clause 4.2.2.2 of RFC 4210 [59]; Root CA certificate.

    | | +| Step 4 (M) | NFO incorporates the enrolment data in NF Deployment initial configuration (including PKI server details). NF Deployment uses this data to request certificate and CA trust certs from Operator PKI. | | +| Step 5 (M) | NFO triggers NF Deployment in O-Cloud over O2 interface using O2-dms. | | +| Step 6 (M) | O-Cloud creates NF Deployment instance. | | +| Step 7(O) | The NFO receives information about the success/failure of the NF Deployment instantiation in the O-Cloud. | | +| Step 8(M) | If the NF deployment was successful, NF Deployment instance generates key pairs & CSR and issues CMPv2 requests to Operator PKI based on the initial configuration. | | +| Step 9(M) | Operator PKI responds with certificate to the NF Deployment instance, including the trust anchors of the domains to which the node will communicate. | | +| Ends when | Initial configuration and certificate are issued for the NF Deployment instance. | | +| Exceptions | None identified | | +| Post-conditions | Trust established between the Cloudified NF and SMO. | | + +``` + +@startuml + +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +autonumber +box #whitesmoke +box "SMO" #cadetBlue +participant "Network Function Install Project Manager" as operator +participant "NFO" as NFO + +end box +participant "Operator PKI" as PKI +participant "O-Cloud" as cloud +box "Cloudified NF" #SkyBlue +participant "NF Deployment" as CNF + +operator->>NFO: NF Deployment request +NFO-->>PKI: Create End Entity as Cloudified NF +Note over NFO, PKI +NFO requests Operator PKI via the vendor specific PKI interface +to create enrolment data for NF Deployment instance +end note + +PKI-->>NFO: Return Initial Authentication Key (IAK) and PKI server details + +Note over NFO, PKI +Operator PKI responds with enrolment data to NFO. Enrolment data +consists of: CMP details associated with provisioned End Entity as Cloudified NF, +including Initial Authentication Key (IAK) and reference value; Root CA trust certificate +end note + +NFO->>NFO: Update NF Deployment for initial configuration + +NFO->>cloud: NF Deployment in O-Cloud via O2dms interface +cloud<-->>CNF: NF Deployment instance +cloud->>NFO: NF Deployment response (success/fail) + +CNF-->>PKI: If the NF deployment was successful, NF Deployment instance \n generates key +pairs & CSR and issues CMPv2 requests to\n Operator PKI +Note over CNF, PKI +NF Deployment requests Operator PKI based on the initial configuration +end note + +PKI-->>CNF: Process CSR and send certificate +Note over CNF, PKI +Operator PKI responds with certificate to the +NF Deployment instance, including the trust anchors +of the domains to which the node will communicate +end note + +@enduml + +``` + +![Sequence diagram for Certificate enrolment for NF Deployment. The diagram shows interactions between SMO (Network Function Install Project Manager, NFO), Operator PKI, O-Cloud, and Cloudified NF (NF Deployment).](33cdf7bd6dd37c418d42691b08bc9034_img.jpg) + +``` + +sequenceDiagram + participant SMO as SMO +Network Function Install Project Manager +NFO + participant Operator PKI + participant O-Cloud + participant Cloudified NF as Cloudified NF +NF Deployment + + SMO->>NFO: 1 NF Deployment request + NFO->>Operator PKI: 2 Create End Entity as Cloudified NF + Note over NFO, Operator PKI: NFO requests Operator PKI via the vendor specific PKI interface to create enrolment data for NF Deployment instance + Operator PKI-->>NFO: 3 Return Initial Authentication Key (IAK) and PKI server details + Note over NFO, Operator PKI: Operator PKI responds with enrolment data to NFO. Enrolment data consists of: CMP details associated with provisioned End Entity as Cloudified NF, including Initial Authentication Key (IAK) and reference value; Root CA trust certificate + NFO->>Operator PKI: 4 Update NF Deployment for initial configuration + NFO->>O-Cloud: 5 NF Deployment in O-Cloud via O2dms interface + O-Cloud-->>Cloudified NF: 6 NF Deployment instance + Cloudified NF-->>O-Cloud: 7 NF Deployment response (success/fail) + Note over O-Cloud, Cloudified NF: If the NF deployment was successful, NF Deployment instance 8 generates key pairs & CSR and issues CMPv2 requests to Operator PKI + Cloudified NF->>Operator PKI: 8 NF Deployment requests Operator PKI based on the initial configuration + Note over Cloudified NF, Operator PKI: NF Deployment requests Operator PKI based on the initial configuration + Operator PKI->>Cloudified NF: 9 Process CSR and send certificate + Note over Operator PKI, Cloudified NF: Operator PKI responds with certificate to the NF Deployment instance, including the trust anchors of the domains to which the node will communicate + +``` + +Sequence diagram for Certificate enrolment for NF Deployment. The diagram shows interactions between SMO (Network Function Install Project Manager, NFO), Operator PKI, O-Cloud, and Cloudified NF (NF Deployment). + +Figure C.3.1-2: Certificate enrolment for NF Deployment + +# Annex D (informative): Mapping of Threats to Requirements and Requirements to Controls + +## D.1 Threats to Requirements Mapping + +**Table D-1: Mapping of Threats defined in [i.14] to Security Requirements** + +| Threat | Threat Title | Security requirements | +|-----------------------------------------------|---------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------| +| Common Threats among O-RAN components | | | +| T-O-RAN-01 | An attacker exploits insecure designs or lack of adoption in O-RAN components | For further study | +| T-O-RAN-02 | An attacker exploits misconfigured or poorly configured O-RAN components | For further study | +| T-O-RAN-03 | Attacks from the internet exploit weak authentication and access control to penetrate O-RAN network boundary | For further study | +| T-O-RAN-04 | An attacker attempts to jam the airlink signal through IoT devices | For further study | +| T-O-RAN-05 | An attacker penetrates and compromises the O-RAN system through the open O-RAN's Fronthaul, O1, O2, A1, and E2 | REQ-SEC-SLM-GSE-5 | +| T-O-RAN-06 | An attacker exploits insufficient/improper mechanisms for authentication and authorization to compromise O-RAN components | REQ-SEC-SLM-GSE-5
    REQ-SEC-SLM-SST-1..7 | +| T-O-RAN-07 | An attacker compromises O-RAN monitoring mechanisms and log files integrity and availability | REQ-SEC-SLM-FLD-2, REQ-SEC-SLM-ATS-1, REQ-SEC-SLM-SST-1..7, REQ-SEC-SLM-STR-1..5, REQ-SEC-SLM-DDA-9 | +| T-O-RAN-08 | An attacker compromises O-RAN data integrity, confidentiality and traceability | REQ-SEC-SLM-DAT-EVT-1..8

    REQ-SEC-SLM-GSE-5

    REQ-SEC-SLM-SST-7, REQ-SEC-SLM-TLD-1..5 | +| T-O-RAN-09 | An attacker compromises O-RAN components integrity and availability | REQ-SEC-SLM-DoS-1..7

    REQ-SEC-SLM-SST-7, REQ-SEC-SLM-TLD-1..5 | +| T-O-RAN-10 | Inconsistent Log Format Impeding Effective Attack Detection | REQ-SEC-SLM-FMT-1, REQ-SEC-SLM-FLD-1..3, REQ-SEC-SLM-FLD-1, REQ-SEC-SLM-FMT-1, REQ-SEC-LCSS-2..5, REQ-SEC-SLM-DDA-1..11 | +| Fronthaul interface and M-S-C-U planes | | | +| T-FRHAUL-01 | An attacker penetrates O-DU and beyond through O-RU or the Fronthaul interface | For further study | +| T-FRHAUL-02 | Unauthorized access to Open Front Haul Ethernet L1 physical layer interface(s) | For further study | +| T-MPLANE-01 | An attacker attempts to intercept the Fronthaul (MITM) over M Plane | For further study | +| T-SPLANE-01 | DoS attack against a Master clock | REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-ATS-1 | +| T-SPLANE-02 | Impersonation of a Master clock (Spoofing) within a PTP network with a fake ANNOUNCE message | REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-ATS-1 | + +| | | | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| T-SPLANE-03 | A Rogue PTP Instance wanting to be a Grand Master | REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-ATS-1 | +| T-SPLANE-04 | Selective interception and removal of PTP timing packets | REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-ATS-1 | +| T-SPLANE-05 | Packet delay manipulation attack | REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-ATS-1 | +| T-CPLANE-01 | Spoofing of DL C-plane messages | For further study | +| T-CPLANE-02 | Spoofing of UL C-plane messages | For further study | +| T-UPLANE-01 | An attacker attempts to intercept the Fronthaul (MITM) over U Plane | For further study | +| O-RU | | | +| T-ORU-01 | An attacker stands up a false base station attack by attacking an O-RU | For further study | +| Near-RT RIC | | | +| T-NEAR-RT-01 | Malicious xApps can exploit UE identification, track UE location and change UE priority | REQ-SEC-NEAR-RT-1 | +| T-NEAR-RT-02 | Risk of deployment of a malicious xApp on Near-RT RIC | REQ-SEC-OCLOUD-PKG-1..3, REQ-SBOM-001..002, REQ-SBOM-004..006, REQ-SEC-NEAR-RT-1..4, REQ-SEC-XAPP-3..4 | +| T-NEAR-RT-03 | Attackers exploit non authenticated, weakly or incorrectly authenticated Near-RT RIC APIs | REQ-SEC-OCLOUD-PKG-1..3, REQ-SBOM-001..002, REQ-SBOM-004..006, REQ-SEC-NEAR-RT-1..4, REQ-SEC-E2-1, SEC-CTL-E2 | +| T-NEAR-RT-04 | Attackers exploit non authorized Near-RT RIC APIs to access to resources and services which they are not entitled to use. | REQ-SEC-NEAR-RT-1..4, REQ-SEC-OCLOUD-PKG-1..3 | +| T-NEAR-RT-05 | Attackers exploit non uniquely identified xApps using a trusted xAppID to access to resources and services which they are not entitled to use. | REQ-SEC-XAPP-3..4, SEC-CTL-NEAR-RT-13..14 | +| Non-RT RIC | | | +| T-NONRTIC-01 | An attacker gains access to the Non-RT RIC through the SMO to cause a denial of service or degrade the performance of the Non-RT-RIC | For further study | +| T-NONRTIC-02 | An attacker gains access to the Non-RT RIC through the SMO for UE tracking | For further study | +| T-NONRTIC-03 | An attacker gains access to the Non-RT RIC through the SMO to cause Data Corruption/Modification | For further study | +| T-NONRTIC-04 | An attacker exploits non uniquely identified rApp instances using a trusted rAppID to access R1 services and data which they are not entitled to use | For further study | +| xAPPs | | | +| T-xApp-01 | An attacker exploits xApps vulnerabilities and misconfiguration | REQ-SEC-OCLOUD-PKG-1..3, REQ-SBOM-001..002, REQ-SBOM-004..006, REQ-SEC-NEAR-RT-1..4 | +| T-xApp-02 | Conflicting xApps unintentionally or maliciously impact O-RAN system functions to degrade performance or trigger a DoS | REQ-SEC-E2-1, SEC-CTL-E2 | +| T-xApp-03 | An attacker compromises xApp isolation | REQ-SEC-NEAR-RT-1..4, REQ-SEC-OCLOUD-PKG-1..3, REQ-TLS-FUN-1..10

    REQ-SEC-SLM-GEN-EVT-1..6, REQ-SEC-SLM-HYP-EVT-1..3, REQ-SEC-SLM-CON-EVT-1..3, REQ-SEC-SLM-APP-EVT-1..2, REQ-SEC-SLM-DAT-EVT-1..8, REQ-SEC-SLM-AAI-EVT-1..10, REQ-SEC-SLM-GSE-1..6, REQ-SEC-SLM-TESS-4, REQ-SEC-SLM-FLD-3, REQ-SEC-SLM-AAI-EVT-4 | + +| | | | +|-------------------------------|---------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------| +| T-xApp-04 | False or malicious A1 policies modify behavior of xApps | REQ-SEC-NEAR-RT-1..7, REQ-SEC-A1-1..2 | +| rAPPs | | | +| T-rAPP-01 | Conflicting rApps impact O-RAN system functions to degrade performance or trigger a DoS | For further study | +| T-rAPP-02 | An attacker exploits rApp vulnerability for data breach or denial of service | For further study | +| T-rAPP-03 | An attacker exploits rApps misconfiguration | For further study | +| T-rAPP-04 | An attacker bypasses authentication and authorization | For further study | +| T-rAPP-05 | An attacker deploys and exploits malicious rApp | For further study | +| T-rAPP-06 | An attacker bypasses authentication and authorization using an injection attack | For further study | +| T-rAPP-07 | rApp exploits services | For further study | +| PNF | | | +| T-PNF-01 | An attacker compromises a PNF to launch reverse attacks and other attacks against VNFs/CNFs | For further study | +| R1 | | | +| T-R1-01 | A malicious actor gains unauthorized access to R1 services | For further study | +| T-R1-02 | Attacker modifies Service Heartbeat message to cause Denial of Service | For further study | +| T-R1-03 | Malicious actor bypasses authentication to Request Data | For further study | +| T-R1-04 | Malicious actor bypasses authorization to Discover Data | For further study | +| T-R1-05 | A malicious actor gains unauthorized access to data | For further study | +| T-R1-06 | Malicious actor modifies a Data Request | For further study | +| T-R1-07 | Malicious actor compromises Data Delivery to the Data Consumer | For further study | +| A1 | | | +| T-A1-01 | Untrusted peering between Non-RT-RIC and Near-RT-RIC | For further study | +| T-A1-02 | Malicious function or application monitors messaging across A1 interface | For further study | +| T-A1-03 | Malicious function or application modifies messaging across A1 interface | For further study | +| Application Life Cycle | | | +| T-AppLCM-01 | Compromise of App/VNF/CNF update package integrity prior to onboarding | REQ-SEC-ALM-PKG-2
    REQ-SEC-ALM-PKG-3
    REQ-SEC-ALM-PKG-4
    REQ-SEC-ALM-PKG-5
    REQ-SEC-ALM-PKG-6 | +| T-AppLCM-02 | Compromise of App/VNF/CNF update image integrity during instantiation | REQ-SEC-OCLOUD-PKG-1
    REQ-SEC-OCLOUD-PKG-2 | + +| | | | +|--------------------|----------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| T-AppLCM-03 | Downgrade attack to vulnerable application version | REQ-SEC-ALM-SU-3 | +| T-AppLCM-04 | Attacker exploits missing or improperly defined elements of application's SecurityDescriptor | REQ-SEC-LCM-SD-1
    REC-SEC-LCM-SD-2 | +| T-AppLCM-05 | Malicious actor modifies application's SecurityDescriptor | Integrity protection of descriptors during delivery and onboarding: REQ-SEC-ALM-PKG-2, REQ-SEC-ALM-PKG-4, REQ-SEC-ALM-PKG-5, REQ-SEC-ALM-PKG-6

    Integrity protection within the catalogue (SMO level): REQ-SEC-ALM-PKG-10, REQ-SEC-ALM-PKG-11

    Integrity protection during the life cycle: REQ-SEC-ALM-PKG-13

    Integrity protection within the O-Cloud: REQ-SEC-OCLOUD-SS-1 | +| T-AppLCM-06 | Improper decommissioning of application | REQ-SEC-ALM-DECOM-1

    REQ-SEC-ALM-DECOM-2

    REQ-SEC-ALM-DECOM-3 | +| T-AppLCM-07 | Improper deletion of application sensitive data | REQ-SEC-OCLOUD-SS-2

    REQ-SEC-OCLOUD-SS-3

    REQ-SEC-OCLOUD-SS-4

    REQ-SEC-OCLOUD-SS-5 | +| E2 | | | +| T-E2-01 | Untrusted Near-RT-RIC and/or E2 Nodes | REQ-SEC-NEAR-RT-9 | +| T-E2-02 | Malicious actor monitors messaging across E2 interface | REQ-SEC-E2-1 | +| T-E2-03 | Malicious actor modifies messaging across E2 interface | REQ-SEC-E2-1 | +| Y1 | | | +| T-Y1-01 | Untrusted Near-RT-RIC and Y1 consumers | REQ-SEC-NEAR-RT-8, REQ-SEC-Y1-1..6 | +| T-Y1-02 | Malicious actor monitors messaging across Y1 interface | REQ-SEC-Y1-3 | +| T-Y1-03 | Malicious actor modifies messaging across Y1 interface | REQ-SEC-Y1-3 | +| O-Cloud | | | +| T-GEN-01 | Software flaw attack | SBOM requirements
    REQ-SEC-OCLOUD-SU-1

    REQ-SEC-OCLOUD-SU-5

    REQ-SEC-OCLOUD-SU-6

    REQ-SEC-OCLOUD-SU-7

    REQ-SEC-SLM-GEN-EVT-1..6, REQ-SEC-SLM-HYP-EVT-1..3, REQ-SEC-SLM-CON-EVT-1..3, REQ-SEC-SLM-APP-EVT-1..2, REQ-SEC-SLM-DAT-EVT-1..8, REQ-SEC-SLM-AAI-EVT-1..10, REQ-SEC-SLM-GSE-1..6, REQ-SEC-SLM-TESS-4, REQ-SEC-SLM-FLD-3, REQ-SEC-SLM-AAI-EVT-4, REQ-SEC-SLM-TESS-3 | +| T-GEN-02 | Malicious access to exposed services using valid accounts | REQ-SEC-OCLOUD-1
    REQ-SEC-OCLOUD-2 | + +| | | | +|------------------|---------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-GEN-03 | Untrust binding between the different O-Cloud layers | REQ-SEC-OCLOUD-COT-1
    REQ-SEC-OCLOUD-COT-2

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-GEN-04 | Lack of Authentication & Authorization in interfaces between O-Cloud components | REQ-SEC-OCLOUD-ISO-1

    REQ-SEC-OCLOUD-ISO-2

    REQ-SEC-OCLOUD-ISO-3

    REQ-SEC-OCLOUD-ISO-4

    REQ-SEC-OCLOUD-ISO-5

    REQ-SEC-OCLOUD-ISO-6

    REQ-SEC-OCLOUD-ISO-7

    REQ-SEC-TESS-1

    REQ-SEC-SLM-GEN-EVT-1..6, REQ-SEC-SLM-HYP-EVT-1..3, REQ-SEC-SLM-CON-EVT-1..3, REQ-SEC-SLM-APP-EVT-1..2, REQ-SEC-SLM-DAT-EVT-1..8, REQ-SEC-SLM-AAI-EVT-1..10, REQ-SEC-SLM-GSE-1..6, REQ-SEC-SLM-TESS-4, REQ-SEC-SLM-FLD-3, REQ-SEC-SLM-AAI-EVT-4, REQ-SEC-SLM-TESS-3 | +| T-GEN-05 | Unsecured credentials and keys | REQ-SEC-OCLOUD-SS-1
    REQ-SEC-OCLOUD-SS-2
    REQ-SEC-OCLOUD-SS-3
    REQ-SEC-OCLOUD-SS-4

    REQ-SEC-SLM-GEN-EVT-1..6, REQ-SEC-SLM-HYP-EVT-1..3, REQ-SEC-SLM-CON-EVT-1..3, REQ-SEC-SLM-APP-EVT-1..2, REQ-SEC-SLM-DAT-EVT-1..8, REQ-SEC-SLM-AAI-EVT-1..10, REQ-SEC-SLM-GSE-1..6, REQ-SEC-SLM-TESS-4, REQ-SEC-SLM-FLD-3, REQ-SEC-SLM-AAI-EVT-4, REQ-SEC-SLM-TESS-3 | +| T-GEN-06 | Sensitive application data cache exploitation | REQ-SEC-OCLOUD-SS-1
    REQ-SEC-OCLOUD-SS-2
    REQ-SEC-OCLOUD-SS-3
    REQ-SEC-OCLOUD-SS-4

    REQ-SEC-OCLOUD-SS-5 | +| T-VM-C-01 | Abuse of a privileged VM/Container | REQ-SEC-OCLOUD-ISO-1
    REQ-SEC-OCLOUD-ISO-2
    REQ-SEC-OCLOUD-ISO-3
    REQ-SEC-OCLOUD-ISO-4

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-VM-C-02 | VM/Container escape attack | REQ-SEC-OCLOUD-ISO-1
    REQ-SEC-OCLOUD-ISO-3

    REQ-SEC-SLM-GEN-EVT-1..6, REQ-SEC-SLM-HYP-EVT-1..3, REQ-SEC-SLM-CON-EVT-1..3, REQ-SEC-SLM-APP-EVT-1..2, REQ-SEC-SLM-DAT-EVT-1..8, REQ-SEC-SLM-AAI-EVT-1..10, REQ-SEC-SLM-GSE-1..6, REQ-SEC-SLM-TESS-4, REQ-SEC-SLM-FLD-3, REQ-SEC-SLM-AAI-EVT-4, REQ-SEC-SLM-TESS-3 | +| T-VM-C-03 | VM/Container data theft | REQ-SEC-OCLOUD-ISO-4 | + +| | | | +|------------------|--------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-VM-C-04 | VM/Container migration attacks | REQ-SEC-LCM-SD-6

    REQ-SEC-ALM-PKG-13

    REQ-SEC-ALM-PKG-15

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-VM-C-05 | Changing virtualization resource without authorization | REQ-SEC-OCLOUD-ISO-1
    REQ-SEC-OCLOUD-ISO-3
    REQ-SEC-O-CLOUD-ISO-4

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-VM-C-06 | Failed or incomplete VNF/CNF termination or releasing of resources | REQ-SEC-ALM-PKG-13

    REQ-SEC-ALM-DECOM-3

    REQ-SEC-ALM-PKG-15

    REQ-SEC-OCLOUD-SS-2

    REQ-SEC-OCLOUD-SS-3

    REQ-SEC-OCLOUD-SS-4

    REQ-SEC-OCLOUD-SS-5

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-IMG-01 | VM/Container images tampering | REQ-SEC-OCLOUD-PKG-1
    REQ-SEC-OCLOUD-PKG-2
    REQ-SEC-OCLOUD-PKG-3
    REQ-SEC-ALM-PKG-1 to REQ-SEC-ALM-PKG-15

    REQ-SEC-SLM-GEN-EVT-1..6, REQ-SEC-SLM-HYP-EVT-1..3, REQ-SEC-SLM-CON-EVT-1..3, REQ-SEC-SLM-APP-EVT-1..2, REQ-SEC-SLM-DAT-EVT-1..8, REQ-SEC-SLM-AAI-EVT-1..10, REQ-SEC-SLM-GSE-1..6, REQ-SEC-SLM-TESS-4, REQ-SEC-SLM-FLD-3, REQ-SEC-SLM-AAI-EVT-4, REQ-SEC-SLM-TESS-3 | +| T-IMG-02 | Insecure channels with images repository | | +| T-IMG-03 | Secrets disclosure in VM/Container images | | +| T-IMG-04 | Build image on VL | | +| T-VL-01 | VM/Container hyperjacking attack | REQ-SEC-OCLOUD-SU-1
    REQ-SEC-OCLOUD-SU-5
    REQ-SEC-OCLOUD-SU-6

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-VL-02 | Boot tampering | REQ-SEC-OCLOUD-COT-1
    REQ-SEC-OCLOUD-COT-2

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-VL-03 | Attack internal network services | REQ-SEC-OCLOUD-ISO-1
    REQ-SEC-OCLOUD-ISO-2
    REQ-SEC-OCLOUD-ISO-3
    REQ-SEC-OCLOUD-ISO-4

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-O2-01 | MitM attacks on O2 interface between O-Cloud and SMO | REQ-SEC-OCLOUD-O2dms-1
    REQ-SEC-OCLOUD-O2dms-2
    REQ-SEC-OCLOUD-O2dms-3
    REQ-SEC-OCLOUD-O2dms-4 | + +| | | | +|-------------------|----------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | REQ-SEC-OCLOUD-O2ims-1
    REQ-SEC-OCLOUD-O2ims-2
    REQ-SEC-OCLOUD-O2ims-3
    REQ-SEC-OCLOUD-O2ims-4

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-OCAPI-01 | MitM attacks on O-Cloud interface between VNFs/CNFs and the virtualization layer | REQ-SEC-O-CLOUD-NotifAPI-1
    REQ-SEC-O-CLOUD-NotifAPI-2

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-HW-01 | Cross VM/Container side channel attacks | REQ-SEC-O-CLOUD-HW-1

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-HW-02 | MitM attacks on the interface between virtualization layer and hardware | To be addressed in a future version

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-ADMIN-01 | Denial of service against NFO/FOCOM | REQ-SEC-DOS-1

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-ADMIN-02 | Abuse a O-Cloud administration service | To be addressed in a future version

    REQ-SEC-SLM-GEN-EVT-1..6, REQ-SEC-SLM-HYP-EVT-1..3, REQ-SEC-SLM-CON-EVT-1..3, REQ-SEC-SLM-APP-EVT-1..2, REQ-SEC-SLM-DAT-EVT-1..8, REQ-SEC-SLM-AAI-EVT-1..10, REQ-SEC-SLM-GSE-1..6, REQ-SEC-SLM-TESS-4, REQ-SEC-SLM-FLD-3, REQ-SEC-SLM-AAI-EVT-4, , REQ-SEC-SLM-TESS-3 | +| T-AAL-01 | Attacker exploits insecure API to gain access to hardware accelerator resources | REQ-SEC-AALI-C-Mgmt-1
    REQ-SEC-AALI-C-Mgmt-2
    REQ-SEC-AALI-C-Mgmt-3
    REQ-SEC-AAL-VS-1
    REQ-SEC-AAL-VS-2
    REQ-SEC-AAL-VS-3
    REQ-SEC-AAL-VS-4

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-AAL-02 | Internal Overload DoS attack targeting AAL services | REQ-SEC-DOS-1

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-AAL-03 | Fail to clear resources | REQ-SEC-AAL-1
    REQ-SEC-AAL-2

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-AAL-04 | HAM compromise | REQ-SEC-AAL-4
    REQ-SEC-AAL-6

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-AAL-05 | Malicious memory accesses | REQ-SEC-AAL-4
    REQ-SEC-AAL-5

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | + +| | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------| +| T-AAL-06 | Firmware attacks | REQ-SEC-AAL-3
    REQ-SEC-AAL-4

    REQ-SEC-SLM-TESS-3, REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1..6 | +| T-O-CLOUD-ID-01 | ID reuse in O-Cloud's object lifecycle | REQ-SEC-OCLOUD-INST-ID-1 | +| T-O-CLOUD-ID-02 | Node redundancy in O-Cloud deployments | REQ-SEC-OCLOUD-INST-ID-2 | +| T-O-CLOUD-ID-03 | O-Cloud ID mismanagement | REQ-SEC-OCLOUD-INST-ID-3

    REQ-SEC-OCLOUD-INST-ID-4

    REQ-SEC-OCLOUD-INST-ID-5 | +| T-TS-01 | Time synchronization disruption in O-Cloud | REQ-SEC-OCLOUD-TS-1

    REQ-SEC-OCLOUD-TS-2

    REQ-SEC-OCLOUD-TS-3

    REQ-SEC-OCLOUD-TS-4

    REQ-SEC-OCLOUD-TS-5 | +| Open source | | | +| T-OPENSRC-01 | Developers use SW components with known vulnerabilities and untrusted libraries that can be exploited by an attacker through a backdoor attack | REQ-SEC-SLM-APP-EVT-2 | +| T-OPENSRC-02 | A trusted developer intentionally inserts a backdoor into an open source code O-RAN component | For further study | +| Physical | | | +| T-PHYS-01 | An intruder into a site gains physical access to O-RAN components to cause damage or access sensitive data | For further study | +| T-PHYS-02 | An intruder into the exchange over the Fronthaul cable network attempts to gain electronic access to cause damage or access sensitive data | For further study | +| Radio networks | | | +| T-RADIO-01 | Disruption through radio jamming, sniffing and spoofing | For further study | +| T-RADIO-02 | DoS attacks on cognitive radio networks | For further study | +| AI/ML | | | +| T-AIML-DP-01 | Black box data poisoning attacks | For further study | +| T-AIML-DP-02 | Grey box data poisoning attacks | For further study | +| T-AIML-DP-03 | White box data poisoning attacks | For further study | +| T-AIML-MEI-01 | Information access-based membership inference attack | For further study | +| T-AIML-MEI-02 | Inference technique-based membership inference attack | For further study | +| T-AIML-MEI-03 | Target based membership inference attack | For further study | +| T-AIML-ME-01 | Intellectual Property Theft | For further study | +| T-AIML-ME-02 | Data Privacy Violations | For further study | +| T-AIML-ME-03 | Adversarial Attacks | For further study | +| T-AIML-IM-1 | Training Data Control | For further study | + +| | | | +|--------------------|---------------------------------------------------|-------------------| +| T-AIML-IM-3 | Testing Data Control | For further study | +| T-AIML-IM-4 | Label Manipulation | For further study | +| T-AIML-IM-5 | AI/ML Query Exploitation | For further study | +| T-AIML-MOI-01 | Black-box model inversion attack | For further study | +| T-AIML-MOI-02 | White-box model inversion attack | For further study | +| T-AIML-SC-01 | Data poisoning | For further study | +| T-AIML-SC-02 | Model tampering | For further study | +| T-AIML-SC-03 | Backdoor attacks | For further study | +| T-AIML-SC-04 | Hardware tampering | For further study | +| T-AIML-SC-05 | Insecure maintenance APIs | For further study | +| T-AIML-SC-06 | Third-party libraries and dependencies | For further study | +| T-AIML-OI-01 | Denial of service | For further study | +| T-AIML-OI-02 | Subscriber QoE change | For further study | +| T-AIML-MP-01 | Model Parameter Poisoning | For further study | +| T-AIML-MP-02 | Inference Algorithm Poisoning | For further study | +| T-AIML-MP-03 | Learning Algorithm Poisoning | For further study | +| T-AIML-MP-04 | Model Control | For further study | +| T-AIML-MS-01 | Data manipulation-based Model skewing attacks | For further study | +| T-AIML-MS-02 | Feedback manipulation-based Model Skewing attacks | For further study | +| T-AIML-TL-01 | Data poisoning | For further study | +| T-AIML-TL-02 | Model stealing | For further study | +| T-AIML-TL-03 | Adversarial examples | For further study | +| T-AIML-TL-04 | Backdoor attacks | For further study | +| T-AIML-EV-01 | Grey-box based data evasion attacks | For further study | +| T-AIML-EL-01 | Model Extraction | For further study | +| T-AIML-EL-02 | Data Inference | For further study | +| T-AIML-EL-03 | Denial of Service | For further study | +| | | | +| Protocol Stack | | | +| T-ProtocolStack-01 | REST API Exploits | For further study | +| T-ProtocolStack-02 | REST API – Broken Object Level Authorization | For further study | +| T-ProtocolStack-03 | JSON Exploits | For further study | +| T-ProtocolStack-04 | HTTP Exploits | For further study | +| T-ProtocolStack-05 | TCP Volumetric DDoS | For further study | +| SMO | | | + +| | | | +|-----------------|-------------------------------------------------------------------------------------------------------------------|-------------------| +| T-SMO-01 | External attacker exploits authentication weakness on SMO | For further study | +| T-SMO-02 | External attacker exploits authorization weakness on SMO | For further study | +| T-SMO-03 | External Overload DoS attack targeted at SMO | For further study | +| T-SMO-04 | Internal attacker exploits authentication weakness on a SMO function | For further study | +| T-SMO-05 | Internal attacker exploits authorization weakness on a SMO function | For further study | +| T-SMO-06 | Internal Overload DoS attack targeted at SMO functions | For further study | +| T-SMO-07 | Internal DoS attack disables internal SMO function(s) or process(es) | For further study | +| T-SMO-08 | Attacker exploits insecure API to gain access to SMO | For further study | +| T-SMO-09 | Sensitive data in transit is exposed to an internal attacker | For further study | +| T-SMO-10 | Sensitive data at rest is exposed to an internal attacker | For further study | +| T-SMO-11 | AI/ML poisoning by internal attacker | For further study | +| T-SMO-12 | AI/ML exposure on external entity | For further study | +| T-SMO-13 | Malicious actor views local logs | For further study | +| T-SMO-14 | Malicious actor modifies local log entries | For further study | +| T-SMO-15 | Malicious actor deletes local logs | For further study | +| T-SMO-16 | Malicious actor intercepts exports of local logs | For further study | +| T-SMO-17 | Malicious external actor gains unauthorized access to logs | For further study | +| T-SMO-18 | Malicious internal actor gains authorized access to logs | For further study | +| T-SMO-19 | Internal attacker exploits O2 interface to view data in transit between SMO and O-Cloud | For further study | +| T-SMO-20 | Internal attacker exploits O2 interface to modify data in transit between SMO and O-Cloud | For further study | +| T-SMO-21 | Internal attacker uses O2 interface via SMO to exploit API vulnerability to gain access to O-Cloud infrastructure | For further study | +| T-SMO-22 | Internal attacker floods O2 interface via SMO to cause DDoS on O-Cloud infrastructure | For further study | +| T-SMO-23 | External attacker uses O2 interface via O-Cloud to exploit API vulnerability to gain access to SMO | For further study | +| T-SMO-24 | External attacker floods O2 interface via O-Cloud to cause DDoS on SMO | For further study | +| T-SMO-25 | External attacker uses O2 interface via O-Cloud to gain authorized access to sensitive data-at-rest at the SMO | For further study | +| T-SMO-26 | External attacker exploits External interface to view data in transit between SMO and external service | For further study | +| T-SMO-27 | External attacker exploits External interface to modify data in transit between SMO and external service | For further study | +| T-SMO-28 | External attacker uses External interface to exploit API vulnerability to gain access to SMO | For further study | +| T-SMO-29 | External attacker floods External interface to cause DDoS at SMO | For further study | + +| | | | +|-----------------------|-----------------------------------------------------------------------------------------------|-------------------| +| T-SMO-30 | External attacker uses External interface to gain access to sensitive data-at-rest at the SMO | For further study | +| T-SMO-31 | External attacker poisons External AI/ML data to corrupt SMO | For further study | +| T-SMO-32 | External attacker poisons External Enrichment Information data sources to corrupt SMO | For further study | +| Shared O-RU | | | +| T-SharedORU-01 | O-DU Tenant accesses O-DU Host | For further study | +| T-SharedORU-02 | O-DU Host accesses O-DU Tenant | For further study | +| T-SharedORU-03 | O-DU Tenant accesses O-DU Tenant | For further study | +| T-SharedORU-04 | Password Attack on OFH M-Plane | For further study | +| T-SharedORU-05 | Untrusted peering to O-DU | For further study | +| T-SharedORU-06 | Untrusted peering to the Shared O-RU | For further study | +| T-SharedORU-07 | Untrusted peering to the SMO | For further study | +| T-SharedORU-08 | SMO Tenant accesses SMO Host | For further study | +| T-SharedORU-09 | SMO Host accesses SMO Tenant | For further study | +| T-SharedORU-10 | O-DU Host accesses O-CU Tenant | For further study | +| T-SharedORU-11 | O-DU Tenant accesses O-CU Host | For further study | +| T-SharedORU-12 | O-DU Tenant accesses O-CU Tenant | For further study | +| T-SharedORU-13 | SMO Host accesses O-CU Tenant | For further study | +| T-SharedORU-14 | SMO Tenant accesses O-CU Host | For further study | +| T-SharedORU-15 | Physical port access to Shared O-RU Host/Tenant | For further study | +| T-SharedORU-16 | Physical port access to O-DU Host/Tenant | For further study | +| T-SharedORU-17 | Physical port access to O-CU Host/Tenant | For further study | +| T-SharedORU-18 | Malicious User Login Attempt to SMO Host/Tenant | For further study | +| T-SharedORU-19 | Malicious User Login Attempt to O-CU Host/Tenant | For further study | +| T-SharedORU-20 | Malicious User Login Attempt to O-DU Host/Tenant | For further study | +| T-SharedORU-21 | Malicious User Login Attempt to Shared O-RU Host/Tenant | For further study | +| T-SharedORU-22 | Unauthorized internal threat actor gains access to data in Shared O-RU | For further study | +| T-SharedORU-23 | Unauthorized external threat actor gains access to data in Shared O-RU | For further study | +| T-SharedORU-24 | Data exposure at Shared O-RU | For further study | +| T-SharedORU-25 | Shared O-RU data exposure at SMO | For further study | +| T-SharedORU-26 | Shared O-RU data exposure at O-DU | For further study | +| T-SharedORU-27 | Exposed data in transit between Shared O-RU and O-DU Host/Tenant | For further study | +| T-SharedORU-28 | Exposed data in transit between Shared O-RU and SMO Host/Tenant | For further study | + +| | | | +|----------------|-----------------------------------------------------------------|-------------------| +| T-SharedORU-29 | Modify/Delete OFH C-Plane messages | For further study | +| T-SharedORU-30 | Clock hijacking on OFH S-Plane | For further study | +| T-SharedORU-31 | Parameter conflicts at Shared O-RU | For further study | +| T-SharedORU-32 | Volumetric DDoS attack from O-DU targeting Shared O-RU | For further study | +| T-SharedORU-33 | Volumetric DDoS attack from SMO targeting Shared O-RU | For further study | +| T-SharedORU-34 | Volumetric DDoS attack targeting O-DU | For further study | +| T-SharedORU-35 | Shared O-RU initialization hijacking by DHCP compromise | For further study | +| T-SharedORU-36 | Shared O-RU M-plane hijacking by DNS compromise | For further study | +| T-SharedORU-37 | Misconfiguration of MNO Host Role | For further study | +| T-SharedORU-38 | Incorrect Assignment of Spectrum Resources | For further study | +| T-SharedORU-39 | Chain of Trust in a Multi-Tenant Environment | For further study | +| T-SharedORU-40 | Hijack of MNO Host Role | For further study | +| T-SharedORU-41 | Not Released Host Role (Host Role resume) | For further study | +| T-SharedORU-42 | Misuse of "sudo" privileges | For further study | +| T-SharedORU-43 | Eavesdropping of unprotected CUSM-plane data within shared O-RU | For further study | +| T-SharedORU-52 | Thrashing O-DU Failovers | For further study | +| T-SharedORU-53 | Dual (Dueling) Active O-DUs | For further study | +| T-SharedORU-54 | Modify/Inject O1 messages at the SMO | For further study | +| T-SharedORU-55 | Set Incorrect Array-Carrier configuration on O-DU (Standby) | For further study | +| T-SharedORU-56 | Modify Array-Carrier pre-configuration on Shared O-RU | For further study | +| T-SharedORU-57 | Modify/Inject M-Plane messages with Array-Carrier configuration | For further study | + +## D.2 Requirements to Controls Mapping + +The Table D-2 reflect the relationship between the defined Security Requirements in this document, and the Security Controls. + +For *Support* column in the Table D-2, the values mean the following: + +- MS: The requirement is Mandatory to Support +EXAMPLE: "shall support", "shall be capable", "shall have the capability", "shall provide the capability", "shall be possible", "shall provide a means to"; "shall provide mechanisms"; "shall be configurable" +- M: The requirement is Mandatory +EXAMPLE: "shall be able to", "shall provide", "shall", "shall be in place" +- OS: The requirement is Optional to Support +EXAMPLE: "may support"; "should support" +- O: The requirement is Optional +EXAMPLE: "should" + +For *Control/s covering the requirement* column, the different values in the Table D-2 mean the following: + +- SEC-CTL ID(s) present – one or several controls are existing and defined by the spec +- Not defining a control, to enable the many implementations that are existing.: Intentionally the control is not defined + +- Control not needed: The requirement is enough specific to not need a control + +**Table D-2: Map between Security Requirements and Security Controls** + +| Requirements | Support | Control/s covering the requirement | +|------------------------|---------|-------------------------------------------------------------------------------| +| SMO | | | +| REQ-SEC-SMO-1 | MS | SEC-CTL-SMO-5
    SEC-CTL-SMO-6 | +| REQ-SEC-SMO-2 | MS | SEC-CTL-SMO-5
    SEC-CTL-SMO-6 | +| REQ-SEC-SMO-3 | MS | SEC-CTL-SMO-1
    SEC-CTL-SMO-3
    SEC-CTL-SMO-4 | +| REQ-SEC-SMO-4 | MS | SEC-CTL-SMO-1
    SEC-CTL-SMO-3 | +| REQ-SEC-SMO-5 | M | Control not needed. | +| REQ-SEC-SMO-6 | M | Control not needed. | +| REQ-SEC-SMO-7 | M | Control not needed. | +| REQ-SEC-SMO-Internal-1 | MS | SEC-CTL-SMO-Internal-1 | +| REQ-SEC-SMO-Internal-2 | MS | SEC-CTL-SMO-Internal-2
    SEC-CTL-SMO-Internal-3 | +| REQ-SEC-SMO-External-1 | MS | SEC-CTL-SMO-External-1 | +| REQ-SEC-SMO-External-2 | MS | SEC-CTL-SMO-External-2
    SEC-CTL-SMO-External-3
    SEC-CTL-SMO-External-4 | +| REQ-SEC-SMO-External-3 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SMO-Log-1 | MS | SEC-CTL-SMO-Log-3
    SEC-CTL-SMO-Log-4
    SEC-CTL-SMO-Log-5 | +| REQ-SEC-SMO-Log-2 | M | SEC-CTL-SMO-Log-1
    SEC-CTL-SMO-Log-2 | + +| | | | +|---------------------|----|------------------------------------------------------------------------------------------| +| REQ-SEC-SMO-Log-3 | OS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SMO-Log-4 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SMO-Log-5 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SMO-Log-6 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SMO-Log-7 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SMO-Log-8 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SMO-Log-9 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SMO-Log-10 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SMO-Log-11 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SMO-Log-12 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-NFO-FOCOM-1 | MS | SEC-CTL-NFO-FOCOM-7
    SEC-CTL-NFO-FOCOM-8 | +| REQ-SEC-NFO-FOCOM-3 | MS | SEC-CTL-NFO-FOCOM-1 | +| REQ-SEC-NFO-FOCOM-4 | MS | SEC-CTL-NFO-FOCOM-2 | +| REQ-SEC-NFO-FOCOM-5 | MS | SEC-CTL-NFO-FOCOM-3
    SEC-CTL-NFO-FOCOM-4
    SEC-CTL-NFO-FOCOM-5
    SEC-CTL-NFO-FOCOM-6 | +| REQ-SEC-NFO-FOCOM-6 | M | Control not needed. | +| REQ-SEC-NFO-FOCOM-8 | M | Control not needed. | + +| Non-RT RIC | | | +|---------------------|----|-------------------------------------------------------------------------------| +| REQ-SEC-NonRTRIC-1 | MS | SEC-CTL- NonRTRIC-1 | +| REQ-SEC-NonRTRIC-2 | M | SEC-CTL- NonRTRIC-1
    SEC-CTL- NonRTRIC-3
    SEC-CTL- NonRTRIC-6 | +| REQ-SEC-NonRTRIC-3 | M | SEC-CTL- NonRTRIC-6 | +| REQ-SEC-NonRTRIC-4 | M | Control not needed. | +| REQ-SEC-NonRTRIC-5 | M | Control not needed. | +| REQ-SEC-NonRTRIC-6 | M | Control not needed. | +| REQ-SEC-NonRTRIC-7 | M | SEC-CTL- NonRTRIC-3 | +| REQ-SEC-NonRTRIC-8 | MS | SEC-CTL- NonRTRIC-4
    SEC-CTL- NonRTRIC-5
    SEC-CTL- NonRTRIC-6 | +| REQ-SEC-NonRTRIC-9 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-NonRTRIC-10 | M | Not defining a control, to enable the many implementations that are existing. | +| Near-RT RIC | | | +| REQ-SEC-XAPP-3 | M | SEC-CTL-NEAR-RT-12
    SEC-CTL-NEAR-RT-14 | +| REQ-SEC-XAPP-4 | M | SEC-CTL-NEAR-RT-13
    SEC-CTL-NEAR-RT-14 | +| REQ-SEC-NEAR-RT-1 | M | SEC-CTL-NEAR-RT-1
    SEC-CTL-NEAR-RT-2 | +| REQ-SEC-NEAR-RT-2 | M | SEC-CTL-NEAR-RT-3 | +| REQ-SEC-NEAR-RT-3 | M | SEC-CTL-NEAR-RT-1
    SEC-CTL-NEAR-RT-2 | + +| | | | +|--------------------------------|----|-------------------------------------------------------------------------------| +| REQ-SEC-NEAR-RT-4 | M | SEC-CTL-NEAR-RT-3 | +| REQ-SEC-NEAR-RT-5 | MS | SEC-CTL-NEAR-RT-4
    SEC-CTL-NEAR-RT-5 | +| REQ-SEC-NEAR-RT-6 | M | Control not needed. | +| REQ-SEC-NEAR-RT-7 | M | SEC-CTL-NEAR-RT-8 | +| REQ-SEC-NEAR-RT-8 | M | SEC-CTL-NEAR-RT-15
    SEC-CTL-NEAR-RT-16 | +| REQ-SEC-NEAR-RT-9 | M | SEC-CTL-NEAR-RT-17 | +| REQ-SEC-NEAR-RT-10 | MS | SEC-CTL-NEAR-RT-8A | +| REQ-SEC-NEAR-RT-11 | MS | SEC-CTL-NEAR-RT-2A | +| O-CU, O-CU, O-RU, O-eNB | | | +| REQ-SEC-OCU-1 | | SEC-CTL-OCU-1 | +| REQ-SEC-ODU-1 | | SEC-CTL-ODU-1 | +| REQ-SEC-ORU-1 | | All security controls in clause 5.2.5 | +| REQ-SEC-ORU-2 | | All security controls in clause 5.2.5 | +| REQ-SEC-OeNB-1 | | SEC-CTL-OeNB-1 | +| O-Cloud | | | +| REQ-SEC-OCLOUD-1 | M | SEC-CTL-OCLOUD-2 | +| REQ-SEC-OCLOUD-2 | M | SEC-CTL-OCLOUD-1 | +| REQ-SEC-OCLOUD-3 | M | SEC-CTL-OCLOUD-1 | +| REQ-SEC-OCLOUD-4 | MS | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|----------------------|----|------------------------------------------------------------------------------------------------------| +| REQ-SEC-OCLOUD-PKG-2 | M | SEC-CTL-ALM-PKG-1
    SEC-CTL-ALM-PKG-3 | +| REQ-SEC-OCLOUD-SW-1 | M | SEC-CTL-OCLOUD-SW-1 | +| REQ-SEC-OCLOUD-ISO-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-ISO-3 | M | SEC-CTL-O-CLOUD-ISO-3 | +| REQ-SEC-OCLOUD-ISO-4 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-ISO-5 | M | SEC-CTL-O-CLOUD-ISO-2 | +| REQ-SEC-OCLOUD-ISO-6 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-ISO-7 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-SU-1 | M | SEC-CTL-OCLOUD-SU-4 | +| REQ-SEC-OCLOUD-SU-5 | M | SEC-CTL-OCLOUD-SU-6 | +| REQ-SEC-OCLOUD-SU-6 | M | SEC-CTL-OCLOUD-SU-5 | +| REQ-SEC-OCLOUD-SU-7 | O | SEC-CTL-OCLOUD-SU-7 | +| REQ-SEC-OCLOUD-SS-1 | M | SEC-CTL-OCLOUD-SS-1 See Annex C for the guidance | +| REQ-SEC-OCLOUD-SS-2 | MS | SEC-CTL-OCLOUD-SS-2 See Annex C for the guidance
    SEC-CTL-OCLOUD-SS-3 See Annex C for the guidance | +| REQ-SEC-OCLOUD-SS-3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-SS-4 | MS | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|-----------------------|----|--------------------------------------------------------------------------------------------------------| +| REQ-SEC-OCLOUD-SS-5 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-COT-1 | MS | SEC-CTL-OCLOUD-COT-1 See Annex C for the guidance
    SEC-CTL-OCLOUD-COT-2 See Annex C for the guidance | +| REQ-SEC-OCLOUD-COT-2 | MS | SEC-CTL-OCLOUD-COT-3 See Annex C for the guidance | +| REQ-SEC-OCLOUD-COT-3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-COT-4 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AALI-C-Mgmt-1 | M | SEC-CTL-AALI-C-Mgmt-2 | +| REQ-SEC-AALI-C-Mgmt-2 | M | SEC-CTL-AALI-C-Mgmt-3 | +| REQ-SEC-AALI-C-Mgmt-3 | MS | SEC-CTL-AALI-C-Mgmt-1 | +| REQ-SEC-AAL-VS-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AAL-VS-2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AAL-VS-3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AAL-VS-4 | OS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AAL-1 | MS | SEC-CTL-AAL-1 | +| REQ-SEC-AAL-2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AAL-3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AAL-4 | O | SEC-CTL-AAL-2 | +| REQ-SEC-AAL-5 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AAL-6 | M | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|----------------------------|----|-------------------------------------------------------------------------------| +| REQ-SEC-OCLOUD-O2dms-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-O2dms-2 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-O2dms-3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-O2dms-4 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-O2ims-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-O2ims-2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-O2ims-3 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-O2ims-4 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-O-CLOUD-NotifAPI-1 | M | SEC-CTL-O-CLOUD-INTERFACE-1
    SEC-CTL-O-CLOUD-INTERFACE-3 | +| REQ-SEC-O-CLOUD-NotifAPI-2 | M | SEC-CTL-O-CLOUD-INTERFACE-2 | +| REQ-SEC-O-CLOUD-SE-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-O-CLOUD-SE-2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-INST-ID-1 | M | SEC-CTL-OCLOUD-INST-ID-1
    SEC-CTL-OCLOUD-INST-ID-2 | +| REQ-SEC-OCLOUD-INST-ID-2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-INST-ID-3 | M | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|--------------------------|---|-----------------------------------------------------------------------------------------------------------------------------------------------| +| REQ-SEC-OCLOUD-INST-ID-4 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-INST-ID-5 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-TS-1 | M | SEC-CTL-OCLOUD-TS-1
    SEC-CTL-SLM-ATS-1
    SEC-CTL-SLM-ATS-2
    SEC-CTL-SLM-ATS-3 | +| REQ-SEC-OCLOUD-TS-2 | M | SEC-CTL-OCLOUD-TS-2
    SEC-CTL-OCLOUD-TS-3 | +| REQ-SEC-OCLOUD-TS-3 | M | Not defining a control, to enable the many implementations that are existing.
    NOTE: See Clause 5.3.8.9.2 for additional security controls. | +| REQ-SEC-OCLOUD-TS-4 | M | Not defining a control, to enable the many implementations that are existing.
    NOTE: See Clause 5.3.8.9.2 for additional security controls. | +| REQ-SEC-OCLOUD-TS-5 | M | Not defining a control, to enable the many implementations that are existing.
    NOTE: See Clause 5.3.8.9.2 for additional security controls. | +| REQ-SEC-OCLOUD-SECPOL-1 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-SECPOL-2 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-SECPOL-3 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-SECPOL-4 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-SECPOL-5 | O | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|-------------------------|----|-------------------------------------------------------------------------------| +| REQ-SEC-OCLOUD-SECPOL-6 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-SECPOL-7 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OCLOUD-SECPOL-8 | O | Not defining a control, to enable the many implementations that are existing. | +| Shared O-RU | | | +| REQ-SEC-SharedORU-1 | M | SEC-CTL-SharedORU-1
    SEC-CTL-SharedORU-2 | +| REQ-SEC-SharedORU-2 | M | SEC-CTL-SharedORU-3 | +| REQ-SEC-SharedORU-3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SharedORU-4 | M | SEC-CTL-SharedORU-4 | +| REQ-SEC-SharedORU-7 | M | SEC-CTL-DOS-1 (DDoS) | +| REQ-SEC-SharedORU-8 | MS | Not defining a control, to enable the many implementations that are existing. | +| A1 Interface | | | +| REQ-SEC-A1-1 | MS | SEC-CTL-A1-1 | +| REQ-SEC-A1-2 | MS | SEC-CTL-A1-2
    SEC-CTL-A1-3 | +| REQ-SEC-A1-3 | MS | Not defining a control, to enable the many implementations that are existing. | +| O1 interface | | | +| REQ-SEC-O1-1 | MS | SEC-CTL-O1-1
    SEC-CTL-O1-4 | +| REQ-SEC-O1-2 | MS | SEC-CTL-O1-2
    SEC-CTL-O1-5 | +| REQ-SEC-O1-3 | MS | SEC-CTL-O1-3 | + +| | | | +|---------------------------------|---------|-------------------------------------------------------------------------------| +| REQ-NAC-FUN-1 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-NAC-FUN-2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-NAC-FUN-3 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-NAC-FUN-4 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-NAC-FUN-5 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-NAC-FUN-6 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-NAC-FUN-7 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-NAC-FUN-8 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-NAC-FUN-9 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-NAC-FUN-10 | O (may) | Not defining a control, to enable the many implementations that are existing. | +| REQ-NAC-FUN-11 | O (may) | Not defining a control, to enable the many implementations that are existing. | +| O2 interface | | | +| REQ-SEC-O2-1 | MS | SEC-CTL-O2-1 | +| REQ-SEC-O2-2 | MS | SEC-CTL-O2-2 | +| REQ-SEC-O2-3 | MS | SEC-CTL-O2-3 | +| E2 interface | | | +| REQ-SEC-E2-1 | MS | SEC-CTL-E2-1 | +| Open Fronthaul Interface | | | +| REQ-SEC-OFCP-1 | MS | Clause 5.2.5.5 Open Fronthaul Point-to-Point LAN Segment | +| REQ-SEC-OFCP-2 | M | Clause 5.2.5.5 Open Fronthaul Point-to-Point LAN Segment | +| REQ-SEC-OFCP-3 | O | SEC-CTL-OFCP-1 | +| REQ-SEC-OFCP-4 | O | SEC-CTL-OFCP-1 | +| REQ-SEC-OFUP-1 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OFUP-2 | MS | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|---------------------|----|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| REQ-SEC-OFUP-3 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OFUP-4 | OS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OFSP-1 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OFSP-2 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OFSP-3 | O | SEC-CTL-OFSP-1
    SEC-CTL-OFSP-2
    O-RAN Synchronization Architecture and Solution Specification [30] Clause 8.2.3 Timing/Synchronization Redundancy & Resiliency provides additional details on redundancy for the Open Fronthaul Synchronization architecture. | +| REQ-SEC-OFSP-4 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OFSP-5 | OS | SEC-CTL-OFSP-3 | +| REQ-SEC-OFSP-6 | OS | SEC-CTL-OFSP-3 | +| REQ-SEC-OFSP-7 | OS | SEC-CTL-OFSP-3 | +| REQ-SEC-OFSP-8 | OS | SEC-CTL-OFSP-4 | +| REQ-SEC-OFHPLS-1 | MS | SEC-CTL-OFHPLS-1
    SEC-CTL-OFHPLS-2
    SEC-CTL-OFHPLS-3
    SEC-CTL-OFHPLS-4
    SEC-CTL-OFHPLS-5
    SEC-CTL-OFHPLS-6
    SEC-CTL-OFHPLS-7
    SEC-CTL-OFHPLS-8 | +| REQ-SEC-OFHPLS-2 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-OFHPLS-3 | MS | SEC-CTL-OFHPLS-9
    SEC-CTL-OFHPLS-10
    SEC-CTL-OFHPLS-11
    SEC-CTL-OFHPLS-12 | +| R1 interface | | | +| REQ-SEC-R1-1 | MS | SEC-CTL-R1-1 | +| REQ-SEC-R1-2 | MS | SEC-CTL-R1-2
    SEC-CTL-R1-3 | +| REQ-SEC-R1-3 | MS | Not defining a control, to enable the many implementations that are existing. | + +| Y1 interface | | | +|------------------------------------------------|----|-------------------------------------------------------------------------------| +| REQ-SEC-Y1-1 | MS | SEC-CTL-NEAR-RT-9
    SEC-CTL-Y1-1 | +| REQ-SEC-Y1-2 | M | SEC-CTL-NEAR-RT-10
    SEC-CTL-Y1-2 | +| REQ-SEC-Y1-3 | MS | SEC-CTL-NEAR-RT-11
    SEC-CTL-Y1-3 | +| REQ-SEC-Y1-4 | M | SEC-CTL-NEAR-RT-11
    SEC-CTL-Y1-3 | +| REQ-SEC-Y1-5 | M | SEC-CTL-NEAR-RT-11
    SEC-CTL-Y1-3 | +| REQ-SEC-Y1-6 | M | SEC-CTL-NEAR-RT-11 (partly) | +| Common Application Lifecycle Management | | | +| REQ-SEC-ALM-PKG-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-2 | M | SEC-CTL-ALM-PKG-1
    SEC-CTL-ALM-PKG-1A | +| REQ-SEC-ALM-PKG-3 | M | SEC-CTL-ALM-PKG-3 | +| REQ-SEC-ALM-PKG-4 | M | SEC-CTL-ALM-PKG-1
    SEC-CTL-ALM-PKG-1A | +| REQ-SEC-ALM-PKG-5 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-6 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-7a | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-7b | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-7c | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-8 | M | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|--------------------|----|-------------------------------------------------------------------------------| +| REQ-SEC-ALM-PKG-9 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-10 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-11 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-12 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-13 | M | SEC-CTL-ALM-PKG-2
    SEC-CTL-ALM-PKG-2A
    SEC-CTL-ALM-PKG-4 | +| REQ-SEC-ALM-PKG-14 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-15 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-PKG-16 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-SU-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-SU-2 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-SU-3 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-SU-4 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-LCM-SD-1 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-LCM-SD-2 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-LCM-SD-3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-LCM-SD-4 | M | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|--------------------------------------------------|----------------------------------------------|-------------------------------------------------------------------------------| +| REQ-SEC-LCM-SD-5 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-LCM-SD-6 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-LCM-SD-7 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-ALM-DECOM-1 | M | Control not needed. | +| REQ-SEC-ALM-DECOM-2 | O | Control not needed. | +| REQ-SEC-ALM-DECOM-3 | M | Control not needed. | +| Network Protocols and Services | | | +| REQ-SEC-NET-1 | M | Not defining a control, to enable the many implementations that are existing. | +| Robustness of Common Transport Protocols | | | +| REQ-SEC-TRAN-1 | O | Not defining a control, to enable the many implementations that are existing. | +| Robustness against Volumetric DDoS Attack | | | +| REQ-SEC-DOS-1 | M | Control not needed. | +| Robustness of OS and Applications | | | +| REQ-SEC-SYS-1 | M | Not defining a control, to enable the many implementations that are existing. | +| Password-Based Authentication | | | +| REQ-SEC-PASS-1 | O | SEC-CTL-PASS-1
    SEC-CTL-PASS-2
    SEC-CTL-PASS-3 | +| Security Log Management | | | +| REQ-SEC-SLM-1 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-TESS-1 to 13 | 1 to 9: M
    10 to 11: MS
    12: M
    13: MS | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|-----------------------------|---------------------------------------|-------------------------------------------------------------------------------| +| REQ-SEC-SLM-
    TESM-1 to 5 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-TESR-1
    to 11 | 1 to 6: M
    7 to 8: MS
    9 to 11: M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-
    SST-1 | M | SEC-CTL-SLM-SST-1 | +| REQ-SEC-SLM-
    SST-2 | M | SEC-CTL-SLM-SST-2 | +| REQ-SEC-SLM-
    SST-3 | M | SEC-CTL-SLM-SST-3 | +| REQ-SEC-SLM-
    SST-4 to 7 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-
    STR-1 to 5 | 1 to 4: M
    5: OS | SEC-CTL-SLM-STR-1
    SEC-CTL-SLM-STR-2 | +| REQ-SEC-SLM-
    FMT-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-
    FLD-1 | M | SEC-CTL-SLM-FLD-1 | +| REQ-SEC-SLM-
    FLD-2 | M | SEC-CTL-SLM-FLD-2 | +| REQ-SEC-SLM-
    FLD-3 | M | SEC-CTL-SLM-FLD-2 | +| REQ-SEC-SLM-
    ATS-1 | M | SEC-CTL-SLM-ATS-1
    SEC-CTL-SLM-ATS-2
    SEC-CTL-SLM-ATS-3 | +| REQ-SEC-SLM-
    ATS-2 to 4 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-
    ATS-5 | M | SEC-CTL-SLM-CTS-1 | +| REQ-SEC-SLM-
    DDA-1 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-
    DDA-2 | O | SEC-CTL-SLM-DDA-1 | + +| | | | +|-----------------------------|------------------------------------------------|-------------------------------------------------------------------------------| +| REQ-SEC-SLM-DDA-3 to 6 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-DDA-7 | O | SEC-CTL-SLM-DDA-2 | +| REQ-SEC-SLM-DDA-8 | O | SEC-CTL-SLM-DDA-3 | +| REQ-SEC-SLM-DDA-9 to 11 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-NET-EVT-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-GEN-EVT-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-GEN-EVT-2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-GEN-EVT-3 | M | SEC-CTL-SLM-GEN-EVT-6
    SEC-CTL-SLM-GEN-EVT-7 | +| REQ-SEC-SLM-GEN-EVT-4 | M | SEC-CTL-SLM-GEN-EVT-1
    SEC-CTL-SLM-GEN-EVT-2 | +| REQ-SEC-SLM-GEN-EVT-5 | M | SEC-CTL-SLM-GEN-EVT-4
    SEC-CTL-SLM-GEN-EVT-5 | +| REQ-SEC-SLM-GEN-EVT-6 | M | SEC-CTL-SLM-GEN-EVT-6
    SEC-CTL-SLM-GEN-EVT-7 | +| REQ-SEC-SLM-HYP-EVT-1 to 3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-CON-EVT-1 to 3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-APP-EVT-1 to 2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-DAT-EVT-1 to 8 | 1: M
    2: O
    3 to 5: M
    6: O
    7 to 8: M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-AAI-EVT-1 to 10 | M | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|-----------------------------------------|-----------------------------|-------------------------------------------------------------------------------| +| REQ-SEC-SLM-GSE-1 to 6 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-LCSS-2 to 5 | 2 to 3: MS
    4: M
    5: MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-POL-5 to 10 | 5 to 8: M
    9: MS
    10: M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-DoS-1 to 7 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-SLM-TLD-1 to 4 | OS | Not defining a control, to enable the many implementations that are existing. | +| Certificate Management Framework | | | +| REQ-SEC-CMF-PNF-1 | MS | SEC-CTL-CMF-PNF-1 | +| REQ-SEC-CMF-PNF-2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-PNF-3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-PNF-4 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-PNF-5 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-PNF-6 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-VNF_CNF-1 | MS | SEC-CTL-CMF-VNF_CNF-1 | +| REQ-SEC-CMF-VNF_CNF-2 | MS | SEC-CTL-CMF-VNF_CNF-2 | +| REQ-SEC-CMF-VNF_CNF-3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-1 | M | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|--------------------------------------------------|----|-------------------------------------------------------------------------------| +| REQ-SEC-CMF-ANYNF-2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-3 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-4 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-5 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-6 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-7 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-8 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-9 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-10 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-11 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-12 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-CMF-ANYNF-13 | O | Not defining a control, to enable the many implementations that are existing. | +| Application Programming Interfaces (APIs) | | | +| REQ-SEC-API-1 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-API-2 | MS | SEC-CTL-API-01 | +| REQ-SEC-API-3 | OS | SEC-CTL-API-02 | +| REQ-SEC-API-4 | O | SEC-CTL-API-03 | +| REQ-SEC-API-5 | M | SEC-CTL-API-04 | +| REQ-SEC-API-6 | M | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|----------------------------------|----|-----------------------------------------------------------------------------------| +| REQ-SEC-API-7 | M | SEC-CTL-API-05 | +| REQ-SEC-API-8 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-API-9 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-API-10 | MS | SEC-CTL-API-02
    SEC-CTL-API-03
    SEC-CTL-API-04 | +| REQ-SEC-API-11 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-API-12 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-API-13 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-API-14 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-API-15 | M | Not defining a control, to enable the many implementations that are existing. | +| Trust Anchor Provisioning | | | +| REQ-SEC-TAP-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-TAP-1a | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-TAP-2 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-TAP-3 | MS | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-TAP-4 | MS | SEC-CTL-TAP-1
    SEC-CTL-TAP-2
    SEC-CTL-TAP-3
    SEC-CTL-TAP-4
    SEC-CTL-TAP-5 | +| REQ-SEC-TAP-5 | M | Not defining a control, to enable the many implementations that are existing. | +| AI/ML Security | | | +| REQ-SEC-AIML-1 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-2 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-3 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-4 | M | Not defining a control, to enable the many implementations that are existing. | + +| | | | +|-----------------|---|-------------------------------------------------------------------------------| +| REQ-SEC-AIML-5 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-6 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-7 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-8 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-9 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-10 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-11 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-12 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-13 | M | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-14 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-15 | O | Not defining a control, to enable the many implementations that are existing. | +| REQ-SEC-AIML-16 | M | Not defining a control, to enable the many implementations that are existing. | +| SBOM | | | +| REQ-SBOM-001 | M | Control not needed. | +| REQ-SBOM-002 | M | Control not needed. | +| REQ-SBOM-003 | M | Control not needed. | +| REQ-SBOM-004 | M | Control not needed. | +| REQ-SBOM-007 | M | SEC-CTL-SBOM-001 | +| REQ-SBOM-011 | M | Control not needed. | + +# Annex E (informative): Summary of O-RAN Security Controls + +**Table E-1. Summary of O-RAN Security Controls** + +| Clauses
    [in this document] | Security Principle -> | Confidentiality | Integrity | Availability | Authentication | Authorization | Additional security requirements | +|-------------------------------|-------------------------------|--------------------------------------------------------------|--------------------------------------------------------------|--------------------------------------------|-----------------------------------------------------------|---------------------------------------------------|----------------------------------------| +| 5 | Security Requirements | | | | | | | +| 5.1 | Architectural Elements | | | | | | | +| 5.1.1 | SMO | TLS 1.2 and 1.3 | TLS 1.2 and 1.3 | Withstand and recover without system crash | mTLS 1.2 and 1.3, with X.509 certificates or PSK | OAuth 2.0 | Secure logging and Security event logs | +| 5.1.2 | Non-RT RIC and rApps | TLS 1.2 and 1.3 | TLS 1.2 and 1.3 | Withstand and recover without system crash | mTLS 1.2 and 1.3, with X.509 certificates or PSK | OAuth 2.0 | Secure logging and Security event logs | +| 5.1.3 | Near-RT RIC and xApps | TLS 1.2 and 1.3, IPsec | TLS 1.2 and 1.3, IPsec | Withstand and recover without system crash | mTLS 1.2 and 1.3, IPsec | OAuth 2.0, IPsec | | +| 5.1.4 | O-CU-CP/UP** | IPsec or DTLS on F1 interface as specified in 3GPP TS 33.501 | IPsec or DTLS on F1 interface as specified in 3GPP TS 33.501 | Withstand and recover without system crash | 3GPP TS 33.501 (5.3.4) for mutual authentication with OAM | 3GPP TS 33.501 (5.3.4) for authorization with OAM | Secure logging and Security event logs | +| 5.1.5 | O-DU** | IPsec or DTLS on F1 interface as specified in 3GPP TS 33.501 | IPsec or DTLS on F1 interface as specified in 3GPP TS 33.501 | Withstand and recover without system crash | 3GPP TS 33.501 (5.3.4) for mutual authentication with OAM | 3GPP TS 33.501 (5.3.4) for authorization with OAM | Secure logging and Security event logs | +| 5.1.6 | O-RU*** | 3GPP TS 33.501 | 3GPP TS 33.501 | Withstand and recover without system crash | 3GPP TS 33.501 (5.3.4) for mutual authentication with OAM | 3GPP TS 33.501 (5.3.4) for authorization with OAM | Secure logging and Security event logs | +| 5.1.7 | O-eNB | 3GPP TS 33.401 | 3GPP TS 33.401 | | 3GPP TS 33.401 | | | + +| | | | | | | | | +|------------|-------------------------------------------|-----------------------------------------------------------------------------------------|-------------------------------------------------|--------------------------------------------|----------------------------------------------------------------------------------|------------------------------------|--------------------------------------------------------------------------------------------| +| 5.1.8 | O-Cloud | TLS 1.2 and 1.3 | TLS 1.2 and 1.3, Digital signature verification | Withstand and recover without system crash | MFA, mTLS 1.2 and 1.3 | RBAC, Principle of Least Privilege | Hardware root of trust, Secure boot/Secure runtime, Secure logging and Security event logs | +| 5.1.9 | Shared O-RU | TLS 1.2 and 1.3 | TLS 1.2 and 1.3 | | mTLS 1.2 and 1.3 | NACM with NETCONF | | +| 5.2 | Interfaces | | | | | | | +| 5.2.1 | A1 | TLS 1.2 and 1.3 | TLS 1.2 and 1.3 | | mTLS 1.2 and 1.3 | OAuth 2.0 | | +| 5.2.2 | O1 | TLS 1.2 and 1.3 | TLS 1.2 and 1.3 | | mTLS 1.2 and 1.3 | NACM with NETCONF | | +| 5.2.3 | O2 | TLS 1.2 and 1.3 | TLS 1.2 and 1.3 | | mTLS 1.2 and 1.3 | OAuth 2.0 | | +| 5.2.4 | E2 | IPsec | IPsec | | IPsec | IPsec | | +| 5.2.5 | Open Fronthaul | Open Fronthaul CUS-Plane and M-Plane have varying security requirements, as shown below | | | | | | +| 5.2.5.1 | C-Plane | MACsec | MACsec | | IEEE 802.1X | IEEE 802.1X | | +| 5.2.5.2 | U-Plane | PDCP*, MACsec | PDCP*, MACsec | | IEEE 802.1X | IEEE 802.1X | | +| 5.2.5.3 | S-Plane | | | | IEEE 802.1X | IEEE 802.1X | | +| 5.2.5.4 | M-Plane | TLS 1.2 and 1.3, or SSHv2 | TLS 1.2 and 1.3, or SSHv2 | | IEEE 802.1X, mTLS 1.2 and 1.3 with PKI X.509 certificates or SSHv2 with Password | IEEE 802.1X, NACM with NETCONF | | +| 5.2.5.5 | Open Fronthaul Point-to-Point LAN Segment | | | | IEEE 802.1X | IEEE 802.1X | | +| 5.2.6 | R1 | TLS 1.2 and 1.3 | TLS 1.2 and 1.3 | | mTLS 1.2 and 1.3 | OAuth 2.0 | | +| 5.2.7 | Y1 | TLS 1.2 and 1.3 | TLS 1.2 and 1.3 | | mTLS 1.2 and 1.3 | OAuth 2.0 | | +| 5.3 | Additional Requirements | | | | | | | + +| | | | | | | | | +|--------|------------------------------------|-----------------|--------------------------------------------|--------------------------------------------|--------------------------------------------|-----------|--------------------------------------| +| 5.3.2 | App LCM | | ETSI GS NFV-SEC 021 and ETSI GS NFV-SOL004 | | ETSI GS NFV-SEC 021 and ETSI GS NFV-SOL004 | | | +| 5.3.3 | Network Protocols and Services | | | | | | Unused protocols are disabled | +| 5.3.4 | Robustness of Transport Protocols | | | | | | Handle unexpected inputs | +| 5.3.5 | Robustness against Volumetric DDoS | | | Withstand and recover without system crash | | | | +| 5.3.6 | Robustness of OS and Applications | | | | | | Identify known vulnerabilities | +| 5.3.7 | Password-based Authentication | | | | | | Password hygiene | +| 5.3.8 | Security Log Management | | | | | | Accountability | +| 5.3.9 | Certificate Management Framework | | | | | | CMPv2, PKI | +| 5.3.10 | API Security | TLS 1.2 and 1.3 | TLS 1.2 and 1.3 | | mTLS 1.2 and 1.3 | OAuth 2.0 | OWASP best practices | +| 5.3.11 | Trust Anchor (TA) Provisioning | | | | | | CMPv2, 3GPP SCS, Security event logs | +| 6.3 | SBOM Requirements for O-RAN | | | | | | US NTIA [17] | + +\*The Packet Data Convergence Protocol (PDCP) provides confidentiality and integrity protection of 5G System Control Plane and User Plane between O-CU-CP and UE. + +\*\* Security requirements and controls specified in 3GPP TS 33.501 are partially represented in this table for O-CU and O-DU. + +\*\*\* 3GPP TS 33.501 specifies security requirements without controls. + +# Annex F (informative): Change history + +| Date | Revision | Description | +|------------|----------|--------------------------------------------------------------------------------| +| 2024.11.27 | 11.00 | Accenture.AO: Editorial modification of requirement to mitigate exploitability | +| 2024.11.27 | 11.00 | AT&T: PKIX Abbreviation | + +| | | | +|------------|-------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.11.27 | 11.00 | AT&T.AO: SBOM Updates to Security Requirements and Controls Specifications | +| 2024.11.27 | 11.00 | DTAG: Changing reference to TR to be an informative reference | +| 2024.11.27 | 11.00 | DTAG: Rewording of O2ims/dms interface mentions to clearly state O2 interface | +| 2024.11.27 | 11.00 | Ericsson.AO: Access to O-Cloud Platform | +| 2024.11.27 | 11.00 | Ericsson.AO: MACsec for S-plane | +| 2024.11.27 | 11.00 | Ericsson.AO: Reformulation of App package validation procedure | +| 2024.11.27 | 11.00 | Ericsson.AO: Update O1 Security Requirements | +| 2024.11.27 | 11.00 | Ericsson.AO: Authorization with the Principle of Least Privilege | +| 2024.11.27 | 11.00 | Ericsson.AO: Summary of Security Controls | +| 2024.11.27 | 11.00 | Ericsson.AO: Correct TLS/mTLS controls specifications | +| 2024.11.27 | 11.00 | Ericsson.AO: Architecture Elements | +| 2024.11.27 | 11.00 | Ericsson.AO: Update O2 Security Requirements | +| 2024.11.27 | 11.00 | Ericsson.AO: Security Requirements for O-Cloud Platform | +| 2024.11.27 | 11.00 | Ericsson: Security requirements for Certificate enrolment for new NF Deployment using CMPv2 | +| 2024.11.27 | 11.00 | Ericsson: To propose the security procedure for SEC-CTL-CMF-VNF_CNF-1 in C.3.1 Certificate enrolment for new NF Deployment based on E/// CR 139 security requirement(REQ-SEC-CMF-VNF_CNF-3) | +| 2024.11.27 | 11.00 | Ericsson: Proposing additional text for API in clause 5.3.10 | +| 2024.11.27 | 11.00 | Ericsson: SRCS Security Terms | +| 2024.11.27 | 11.00 | Keysight: Correction in the DoS Control | +| 2024.11.27 | 11.00 | Keysight.AO: New informative Annex to map security requirements and controls | +| 2024.11.27 | 11.00 | MITRE.AO: Update ETSI NFV App Pkg security control | +| 2024.11.27 | 11.00 | NEC: Security requirements for sanitization of AI/ML Model data | +| 2024.11.27 | 11.00 | NEC: Security requirements for feature selection training of AI/ML Model | +| 2024.11.27 | 11.00 | NEC: Security requirements for the transformation of AIML Model input data | +| 2024.11.27 | 11.00 | NEC: Security requirements for adversarial training of AI/ML Model | +| 2024.11.27 | 11.00 | NEC.AO: Security requirements for AI model poisoning control | +| 2024.11.27 | 11.00 | NOKIA: MACsec ciphers conditional | +| 2024.11.27 | 11.00 | NOKIA: Security requirements for AI data security | +| 2024.11.27 | 11.00 | NOKIA: Security requirements for AI Differential Privacy | +| 2024.11.27 | 11.00 | NOKIA: Security requirements for AI model protection | +| 2024.11.27 | 11.00 | NOKIA: Security requirements for AI model integrity and confidentiality | +| 2024.11.27 | 11.00 | NOKIA: Security requirements for AI Model Splitting | +| 2024.11.27 | 11.00 | NOKIA: Security requirements for notifications and/or alarms for certificate storage exhaustion. | +| 2024.11.27 | 11.00 | NOKIA: Y1security controls completion | +| 2024.11.27 | 11.00 | NOKIA: Near-RT RIC: A1 security requirements completion | +| 2024.11.27 | 11.00 | NOKIA: Security requirements for monitoring the expiry of vendor-signed certificates for PNFs | +| 2024.11.27 | 11.00 | NOKIA: Security requirements for notifications and/or alarms related to CRL failures | +| 2024.11.27 | 11.00 | Red Hat: Modifications of O-Cloud certificate management requirements | +| 2024.11.27 | 11.00 | Red Hat.AO: Removal of O-Cloud certificate management control for VNFs/CNFs certificates in a VNFs/CNFs section | +| 2024.11.27 | 11.00 | Rakuten Mobile.AO: Usage of Operator CA for issuing certificates for O-Cloud O2 interface | +| 2024.11.27 | 11.00 | Rakuten Mobile.AO: Security control: O-Cloud platform support for encryption | +| 2024.11.27 | 11.00 | WG11.AO: Update on the O-Cloud signature verification to align with the App LCM requirements | +| 2024.11.27 | 11.00 | WG11.AO: Addition of U-Plane authentication and authorization requirements, along with the corresponding 802.1X control, aligned with the C-Plane | +| 2024.11.27 | 11.00 | WG11.AO: Update to security requirements 5 to 7 on the security descriptor: NFO responsibility for Application descriptor and resource monitoring | +| 2024.11.27 | 11.00 | WG11.AO: Addition of requirements and controls for the enforcement of security policies by the O-Cloud | +| 2024.11.27 | 11.00 | WG11.AO: Addition of a new security requirement and associated control to enhance protection against side-channel attacks on O-Cloud secure environment. | +| 2024.07.14 | 10.00 | Accenture.AO: Separation of non-atomic requirements | +| 2024.07.14 | 10.00 | Accenture.AO: Editorial Changes and corrections conform to O-RAN Rules | +| 2024.07.14 | 10.00 | Ericsson.AO: Making LDAP the preferred protocol for centralized user management | +| 2024.07.14 | 10.00 | Ericsson.AO: Update Shared O-RU Security Requirements | +| 2024.07.14 | 10.00 | Ericsson: Security requirements for improving least privilege of O1 NACM | +| 2024.07.14 | 10.00 | Ericsson: Clarification of using micro perimeter terminology | +| 2024.07.14 | 10.00 | NIST.AO: Splitting Compound O-RAN Requirements | + +| | | | +|------------|-------|---------------------------------------------------------------------------------------------------------------------------------| +| 2024.07.14 | 10.00 | Rakuten Mobile.AO: Adding security control for Near-RT RIC for validation of data received from an xApp through E2 related APIs | +| 2024.07.14 | 10.00 | Rakuten Symphony.AO: End-to-End MACsec as a security control to protect C-Plane messages | +| 2024.07.14 | 10.00 | Rakuten Symphony.AO: IEEE 1588 Authentication TLV for securing S-Plane ANNOUNCE messages. | +| 2024.07.14 | 10.00 | Rakuten Symphony.AO: End-to-End MACsec as a security control to protect U-Plane messages | +| 2024.07.14 | 10.00 | Rakuten Symphony: Consistency of Security Control for Non RT-RIC based on the security control defined for R1 | +| 2024.07.14 | 10.00 | WG11.AO: Addition of the mapping Threats-Requirements | +| 2024.07.14 | 10.00 | WG11.AO: Addition of sensitive definition | +| 2024.03.20 | 09.00 | AT&T.AO: Correct usages of “Must” | +| 2024.03.20 | 09.00 | Ericsson: Update NFO and FOCOM security requirements and controls | +| 2024.03.20 | 09.00 | Ericsson: Add Shared O-RU Security Requirements | +| 2024.03.20 | 09.00 | Keysight.AO: Added unexpected input management requirements for S-Plane and C-Plane | +| 2024.03.20 | 09.00 | MITRE: Resolve duplicate requirement reference IDs in SLM section | +| 2024.03.20 | 09.00 | MITRE: SRS Typos in SLM Reqs | +| 2024.03.20 | 09.00 | NEC.AO: Removal of Requirement REQ-SEC-DEL-1, REQ-CTL-DEL-1, REQ-CTL-DEL-2 | +| 2024.03.20 | 09.00 | NOKIA.AO: Security requirements for PSK/Refnum based certificate enrolment | +| 2024.03.20 | 09.00 | NOKIA.AO: Security requirements for vendor root CA certificate renewal for PNFs | +| 2024.03.20 | 09.00 | NOKIA.AO: Security requirements for Certificate Renewal procedure for PNFs, CNFs and VNFs | +| 2024.03.20 | 09.00 | NOKIA.AO: Security requirements for vendor certificate based certificate initial enrolment for PNFs | +| 2024.03.20 | 09.00 | Rakuten Symphony: Correction to 802.1X security control clause | +| 2024.03.20 | 09.00 | WG11.AO: New requirement for the support of CMPv2 by VNF/CNF | +| 2024.03.20 | 09.00 | WG11.AO: Update of O-Cloud controls on secure storage | +| 2024.03.20 | 09.00 | WG11: New requirements focusing on O-Cloud SW images verification, vulnerability scanning and secure update | +| 2023.11.06 | 08.00 | Ericsson: Update the outdated reference of 3GPP references in Clause 2 and Annex B | +| 2023.11.06 | 08.00 | Ericsson: Editorial update in Clause 5.1.2.2 Security Controls | +| 2023.11.06 | 08.00 | Ericsson: Proposed changes in Clause 5.3.2 Common Application Lifecycle Management | +| 2023.11.06 | 08.00 | MITRE: New requirements on rAppIDs | +| 2023.11.06 | 08.00 | MITRE: New requirement on App decommissioning | +| 2023.11.06 | 08.00 | MITRE: Duplicate Account and Identity Security Event Log Requirement. | +| 2023.11.06 | 08.00 | NIST: SecRecSpec-O1-Interface-Modification | +| 2023.11.06 | 08.00 | NOKIA.AO: Near-RT RIC Secure mechanisms for Y1 interface | +| 2023.11.06 | 08.00 | NOKIA: Security requirements and controls for xApp registration procedure | +| 2023.11.06 | 08.00 | NOKIA: Security requirements for preventing tampering of log data | +| 2023.11.06 | 08.00 | NOKIA: security requirements for prevention of (D)DoS to Security Log Data management | +| 2023.11.06 | 08.00 | NOKIA: Security requirements for prevention of (D)DoS to Security Log Data management | +| 2023.11.06 | 08.00 | NOKIA: Security Log data one-way access | +| 2023.11.06 | 08.00 | NOKIA: Near-RT RIC Secure mechanisms for E2 interface | +| 2023.11.06 | 08.00 | Rakuten Symphony: New security requirements and controls for NFO/FOCOM | +| 2023.11.06 | 08.00 | Rakuten Symphony: New security controls for DoS / DDoS mitigation requirement REQ-SEC-DOS-1 | +| 2023.11.06 | 08.00 | Rakuten Symphony: New security control covering REQ-SEC-AAL-4 | +| 2023.11.06 | 08.00 | Rakuten Symphony: New Security Control for User Management Requirements for Cloud Platform Management | +| 2023.11.06 | 08.00 | WG11: New requirements on O-Cloud logging | +| 2023.11.06 | 08.00 | WG11: New requirements on O-Cloud instance ID | +| 2023.11.06 | 08.00 | WG11: New requirements on O-Cloud Time Synchronization | +| 2023.07.12 | 07.00 | AT&T.AO: Security Requirements specifications CMPv2 | +| 2023.07.12 | 07.00 | AT&T.AO: Security Requirements specifications TA Provisioning | +| 2023.07.12 | 07.00 | Ericsson.AO: API Security Requirements | +| 2023.07.12 | 07.00 | Ericsson.AO: Update to informative SBOM statements | +| 2023.07.12 | 07.00 | Ericsson.AO: Revise Password requirements clause | +| 2023.07.12 | 07.00 | Ericsson: Shared O-RU Security Requirements and Security Controls | +| 2023.07.12 | 07.00 | Ericsson: Kafka Security Requirements | +| 2023.07.12 | 07.00 | Fujitsu.AO: Update Security requirements documents with secure deletion | +| 2023.07.12 | 07.00 | Fujitsu: Update Security requirements documents with secure decommissioning | +| 2023.07.12 | 07.00 | MITRE.AO: Common application package requirements | + +| | | | +|------------|-------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.07.12 | 07.00 | MITRE: Security Log Management requirement for a standard security log format and security related log fields | +| 2023.07.12 | 07.00 | MITRE: Common application package security controls | +| 2023.07.12 | 07.00 | MITRE: Common application terminology | +| 2023.07.12 | 07.00 | MITRE: Security related activities and events to be logged | +| 2023.07.12 | 07.00 | MITRE: PART 2: Security related activities and events to be logged | +| 2023.07.12 | 07.00 | NOKIA: First security log management related requirements | +| 2023.07.12 | 07.00 | NOKIA: Near-RT RIC Secure mechanisms for A1 interface | +| 2023.07.12 | 07.00 | NOKIA: Security requirements for the Y1 interface | +| 2023.07.12 | 07.00 | NOKIA: Security requirements for storage and transfer of logs | +| 2023.07.12 | 07.00 | NOKIA: Security requirements on Trusted Environment for Cluster Node | +| 2023.07.12 | 07.00 | NOKIA: Security requirements on Trusted Environment for Log-data Repository | +| 2023.07.12 | 07.00 | NOKIA: Security Requirements for Log-data Lifecycle Management | +| 2023.07.12 | 07.00 | NOKIA: Security controls for the Y1 interface solution 1 | +| 2023.07.12 | 07.00 | NOKIA: Security Requirements for Time stamps in Log-data | +| 2023.07.12 | 07.00 | NOKIA: Security requirements for Authenticated Time Stamping (Sol#5) and (Missing) Common Time Source (Sol#15) | +| 2023.07.12 | 07.00 | NOKIA: Security Requirements for Due Diligence and (Security) Log-Data Auditing (Sol#6) | +| 2023.07.12 | 07.00 | NOKIA: Security requirements for the support of syslog over tls | +| 2023.07.12 | 07.00 | Rakuten Symphony :Remove references to and datastores for NACM rules of O1 interface | +| 2023.07.12 | 07.00 | Rakuten Symphony: NACM group O1_software_management of O1 interface is applicable only for PNFs | +| 2023.07.12 | 07.00 | Rakuten Symphony.AO: New security requirements and controls for O-Cloud hardware | +| 2023.07.12 | 07.00 | Rakuten Symphony.AO: New security requirements and controls for O-Cloud Virtualization and Isolation | +| 2023.07.12 | 07.00 | Rakuten Symphony: ETSI PAS Adaption for O-RAN Security Requirement Specification | +| 2023.07.12 | 07.00 | Rakuten Symphony.AO: Rename the Security Requirement Specification document to include Security Controls | +| 2023.07.12 | 07.00 | Rakuten Symphony.AO: ETSI Adaptation and changes for the Near-RT RIC Section in the Security Requirement Specification | +| 2023.07.12 | 07.00 | Rakuten Symphony.AO: ETSI Adaptation and Changes for the Security Requirement Specification_Ocloud | +| 2023.07.12 | 07.00 | Rakuten Symphony: ETSI PAS Adaption for O-RAN Security Requirement Specification Interfaces maintained by ORAN | +| 2023.07.12 | 07.00 | Rakuten Symphony: ETSI PAS Adaption for O-RAN Security Requirement Specification_Ph3_Section5.3_Transversal Requirements | +| 2023.07.12 | 07.00 | WG11: Update on the requirement REQ-SEC-DOS-1 against O-RAN DoS attacks | +| 2023.07.12 | 07.00 | WG11: Minor updates: VNF/CNF are replaced by Application, some reference have been updated | +| 2023.03.21 | 06.00 | Ericsson: Update format for references to O-RAN documents | +| 2023.03.21 | 06.00 | Ericsson: O-Cloud Management User Authentication and Authorization | +| 2023.03.21 | 06.00 | Ericsson: SMO Security Requirements and Security Controls | +| 2023.03.21 | 06.00 | Orange: New security requirements on AAL components | +| 2023.03.21 | 06.00 | Orange: New security requirements on security descriptor | +| 2023.03.21 | 06.00 | Qualcomm Incorporated: Security requirements and controls for O-CU-CP/UP, O-DU, O-RU and O-eNB | +| 2023.03.21 | 06.00 | Orange: New security requirements on AAL interfaces | +| 2023.03.21 | 06.00 | MITRE: New security requirements on secure update for apps/VNFs/CNF | +| 2023.03.21 | 06.00 | Orange: New security requirements on the protection of O2 interface and O-Cloud notification APIs | +| 2023.03.21 | 06.00 | MITRE: Update SBOM requirements from AppLCMSec TR recommendation | +| 2022.11.10 | 05.00 | Tbd. | +| 2022.07.20 | 04.00 |

    Added/updated requirements and controls for:

    • • O-Cloud Image Security
    • • Non-RT RIC, rApps, and A1 and R1 Interfaces
    • • Near-RT RIC
    | +| 2022.03.23 | 03.00 |

    Added/updated requirements and controls for:

    • • Near-RT RIC and xApps
    • • Open Fronthaul Interface - C, S and U Planes
    • • Open Fronthaul Point-to-Point LAN Segment
    | + +| | | | +|------------|-------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2021.11.09 | 02.00 |

    Added requirements for

    • • Open Fronthaul Point-to-Point LAN Segment
    • • SBOM
    • • Network Protocols and Services
    • • Robustness of Common Transport Protocols
    • • Robustness against Volumetric DDoS Attack
    • • Robustness of OS and Applications

    Password-Based Authentication

    | +| 2021.07.01 | 01.00 | Final initial version 01.00 | + +### History + +| Date | Revision | Description | +|------------|----------|----------------------------------| +| 2024.11.27 | 11.00 | Published as Final version 11.00 | +| 2024.07.14 | 10.00 | Published as Final version 10.00 | +| 2024.03.20 | 09.00 | Published as Final version 09.00 | +| 2023.11.06 | 08.00 | Published as Final version 08.00 | +| 2023.07.14 | 07.00 | Published as Final version 07.00 | +| 2023.03.22 | 06.00 | Published as Final version 06.00 | +| 2022.11.18 | 05.00 | Published as Final version 05.00 | +| 2022.07.20 | 04.00 | Published as Final version 04.00 | +| 2022.03.23 | 03.00 | Published as Final version 03.00 | +| 2021.11.09 | 02.00 | Published as Final version 02.00 | +| 2021.07.01 | 01.00 | Published as Final version 01.00 | \ No newline at end of file diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/17398cfc35dde22fa5a80caabe669739_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/17398cfc35dde22fa5a80caabe669739_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ae115f85c71c7c4dd5ac246f8d02e9dc29c8af6 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/17398cfc35dde22fa5a80caabe669739_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c5775240b9ed1a2100a9c61aca08d03763ec191986acc2c52895232c0e85e48b +size 4429 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/24bfc42bd397863515083293d98bda3e_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/24bfc42bd397863515083293d98bda3e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3f105ebe4c864bd757cc24c205ee36184f5a425a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/24bfc42bd397863515083293d98bda3e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e56ec157ed05acacccb3c5d36e50a119a77b4c755a5a2c380911632076129e2b +size 45026 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/2f87e3619117952a875a1e85146094da_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/2f87e3619117952a875a1e85146094da_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..870fa81202de6c42c883c46511a4cce3fbee2a7a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/2f87e3619117952a875a1e85146094da_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8c8b610dc613ca5655cd3575ca58858f83fc028298e74cb1d6b9ead67eace0da +size 79163 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/558b0f5362d427a561a4980c84e07bba_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/558b0f5362d427a561a4980c84e07bba_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e46a158eeb7fdc3c68e4021bb22ea8e594986a52 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/558b0f5362d427a561a4980c84e07bba_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3365cf0bfde938265dc44e3dbf5f55a45fa1c5d06489e86529e62e43b3dea7a4 +size 44133 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/59bc9dbeea16696908bb4044da95fbac_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/59bc9dbeea16696908bb4044da95fbac_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ae3a1a3e4b09de193cb2f5353ec1448449e66b9a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/59bc9dbeea16696908bb4044da95fbac_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d7525837da6d54a4fee9faec7c7b077661269612d3d8e3b526a2d8cab4252788 +size 48598 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/5cbeda3247f593f05710c0f6cf112650_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/5cbeda3247f593f05710c0f6cf112650_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..158e550618d8c04d058ec67e9b22e7ddbd2c2cb0 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/5cbeda3247f593f05710c0f6cf112650_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:962d7b2490837aa43046e7c62ecea38769df92c81dce87ed37c865506457d459 +size 18294 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/89b38dfb0db99f01009cbd6fb999f3e3_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/89b38dfb0db99f01009cbd6fb999f3e3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..48c1376370ec5a3cdc6ae6110e0d410ca2179822 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/89b38dfb0db99f01009cbd6fb999f3e3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3b7db7059ddf1b7e367e6a581fa2e151796d00eda05fb4d415279d9851e132bc +size 45703 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/89f6747be259110cba3e5c06cf208a72_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/89f6747be259110cba3e5c06cf208a72_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a64e58c9c6f29c65752cae9345bb0742721097eb --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/89f6747be259110cba3e5c06cf208a72_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:36560e397829d3fda6d425647f4eb28ad93dfadbeda644226f6873b5bb7a227e +size 44236 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/964c20dffc46b8dc92c69a7df97537cb_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/964c20dffc46b8dc92c69a7df97537cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d9b754f1653526efe20f90913227c8f500e1fc78 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/964c20dffc46b8dc92c69a7df97537cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:63e37af54d738f0ce825042bdaf8adb1479f7a24eb3a46db616a889c68fb1b15 +size 44895 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/9c31fa0e3f197c05332681ea00b93e4a_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/9c31fa0e3f197c05332681ea00b93e4a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4c533ff1b5972f5bf69518c494310a3650678d2e --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/9c31fa0e3f197c05332681ea00b93e4a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1d4fc89b417e7afb773e149de4e62e423b6c6235be7c2ae410b00aaa55d54b7d +size 44686 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/b991f6dd9f96ef880216f721ee18f440_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/b991f6dd9f96ef880216f721ee18f440_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c26eacb3d415ab669b973345498ccf54e11e3ea5 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/b991f6dd9f96ef880216f721ee18f440_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:93d9e0d81de30f5e8df46f6e7fe40533aecfacda2e343834797a3ea84b8867fc +size 45299 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7575c364a05dd515d7cf096c30ffc26f8ab2631 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b321cfff0a169d11fa6daa2e14ee4667e12bcfeff34e35ee9dd80b810a6385a6 +size 4491 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/c51aa95f241be1e009b036a321c5f3e2_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/c51aa95f241be1e009b036a321c5f3e2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2aa6cc58d2a872188b30489d23f861cadcd132ad --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/c51aa95f241be1e009b036a321c5f3e2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c1c748aec1fedf3ed59a99e903bbd0b449649c596281c4e05ec0f028078b57d4 +size 24640 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2607b0eef27677fb38e9fdbba214fde5d86a7f72 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9e383e92647a2356488a833110e26ad296a5dd136dd01f365e78a67474a8258 +size 4548 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/f11c22832f1b704bc78d6534ae671707_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/f11c22832f1b704bc78d6534ae671707_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..177351ab5ef5b4ac9c28fee6595310aa3c7c929b --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/f11c22832f1b704bc78d6534ae671707_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:018b00f084ea7ed43fdf85c27fd850157cebe839c4f8c5fa879c60df49e9c2a5 +size 4512 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/f88a52b8a4aaeb13886e77f02f1a348a_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/f88a52b8a4aaeb13886e77f02f1a348a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e1a8fb41833517e763edd767c221005dae5f516a --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/f88a52b8a4aaeb13886e77f02f1a348a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ae1fde261e399c7a3432c4303db0a7475d720c291731ffd1bfe16f6ffdd5c66d +size 44465 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/fdcb46f6325fceb68b1205598510159c_img.jpg b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/fdcb46f6325fceb68b1205598510159c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3832dd3fc2464c5349be6955062123822440801e --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/fdcb46f6325fceb68b1205598510159c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d01dcef35321aa7e577b8db1c5534250319c09b299c4681dc086710ff65a3bad +size 44652 diff --git a/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/raw.md b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..6709f670cfab590c1315ebab7c14d77074688ace --- /dev/null +++ b/marked/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00/raw.md @@ -0,0 +1,9567 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)****O-RAN Security Test Specifications** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|--------------------------------------------------------------|----| +| List of figures ..... | 8 | +| List of tables ..... | 8 | +| Foreword ..... | 9 | +| Modal verbs terminology ..... | 9 | +| 1 Scope ..... | 10 | +| 2 References ..... | 11 | +| 2.1 Normative references ..... | 11 | +| 2.2 Informative references ..... | 12 | +| 3 Definition of terms, symbols and abbreviations ..... | 13 | +| 3.1 Terms 13 | | +| 3.2 Symbols ..... | 13 | +| 3.3 Abbreviations ..... | 14 | +| 4 Objectives and scope ..... | 16 | +| 5 Testing methodology and configuration ..... | 17 | +| 5.1 DUT / SUT ..... | 17 | +| 5.2 Test Setup ..... | 18 | +| 5.3 Test and measurement equipment and tools ..... | 18 | +| 5.4 Test report ..... | 20 | +| 5.5 Assumptions ..... | 20 | +| 5.6 Testing tools ..... | 20 | +| 6 Security Protocol & APIs Validation ..... | 23 | +| 6.1 Overview ..... | 23 | +| 6.2 SSH Server & Client ..... | 23 | +| 6.3 TLS 24 | | +| 6.4 DTLS 25 | | +| 6.5 IPsec 26 | | +| 6.5.1 IPsec security ..... | 26 | +| 6.5.2 IKE Header Flags Fuzzing ..... | 27 | +| 6.5.3 IKE Key Exchange Payload Fuzzing ..... | 28 | +| 6.5.4 IKE Malformed Certificate Payload ..... | 29 | +| 6.6 OAuth 2.0 ..... | 30 | +| 6.7 NACM ..... | 33 | +| 6.7.1 NACM RBAC Configuration ..... | 33 | +| 6.7.2 NACM Logging Monitoring ..... | 34 | +| 6.7.3 Void 35 | | +| 6.8 802.1X ..... | 35 | +| 6.9 X.509 35 | | +| 6.9.1 X.509 Certificate Structure Verification for TLS ..... | 35 | +| 6.9.2 X.509 Certificate Validity Period Verification ..... | 37 | +| 6.9.3 X.509 Certificate Key Usage Verification ..... | 38 | +| 6.9.4 X.509 Certificate Chain Validation ..... | 38 | +| 6.10 eCPRI ..... | 39 | +| 6.10.1 Void 39 | | +| 6.10.2 eCPRI Input Validation ..... | 39 | +| 6.10.3 eCPRI Error and Timeout Handling ..... | 40 | +| 6.10.4 Void 41 | | +| 6.10.5 eCPRI Logging and Auditing ..... | 41 | + +| | | +|----------------------------------------------------------------------------------------|----| +| 6.10.6 Void | 42 | +| 6.11 Sctp ..... | 42 | +| 6.11.1 Void | 42 | +| 6.11.2 Void | 42 | +| 6.11.3 Void | 42 | +| 6.11.4 Void | 42 | +| 6.11.5 Sctp DoS Prevention Rate Limiting..... | 42 | +| 6.11.6 Sctp Input Validation ..... | 43 | +| 6.11.7 Void | 44 | +| 6.11.8 Void | 44 | +| 6.12 Transactional APIs ..... | 44 | +| 6.12.1 Transactional API Authentication..... | 44 | +| 6.12.2 Transactional API Authorization and Access Control ..... | 45 | +| 6.12.3 Transactional API Input Validation and Sanitization ..... | 46 | +| 6.12.4 Transactional API Security Logging and Monitoring..... | 48 | +| 7 Common Network Security Tests for O-RAN architecture elements ..... | 49 | +| 7.1 Overview ..... | 49 | +| 7.2 Network Protocol and Service Enumeration ..... | 49 | +| 7.2.1 Network Protocol and Service Enumeration ..... | 49 | +| 7.3 Password-Based Authentication..... | 50 | +| 7.3.1 Password guessing..... | 50 | +| 7.3.2 Unauthorized Password Reset..... | 52 | +| 7.3.3 Password Policy Enforcement..... | 53 | +| 7.4 Network Protocol Fuzzing ..... | 54 | +| 7.5 Denial of Service/Message Flooding ..... | 56 | +| 7.5.1 Protocol, Application and Volumetric Based DDoS Attacks ..... | 56 | +| 7.5.2 Void | 57 | +| 7.5.3 Void | 57 | +| 7.5.4 Void | 57 | +| 7.5.5 Near-RT RIC A1 interface DoS/DDoS protection and recovery ..... | 57 | +| 7.6 Input validation and error handling ..... | 58 | +| 7.6.1 O-CU input validation and error handling ..... | 58 | +| 7.6.2 O-DU input validation and error handling ..... | 59 | +| 7.6.3 Near-RT RIC input validation and error handling ..... | 61 | +| 7.6.4 Near-RT RIC input validation and error handling of data received from xApp ..... | 62 | +| 7.7 Secure configuration enforcement ..... | 63 | +| 7.8 Logging and monitoring..... | 64 | +| 7.8.1 O-CU logging and monitoring ..... | 64 | +| 7.8.2 O-DU logging and monitoring ..... | 66 | +| 7.8.3 O-RU logging and monitoring ..... | 67 | +| 7.8.4 Near-RT RIC logging and monitoring ..... | 68 | +| 8 System security evaluation for O-RAN architecture elements ..... | 69 | +| 8.1 Overview ..... | 69 | +| 8.2 System Vulnerability Scanning..... | 69 | +| 8.2.1 System Vulnerability Scanning..... | 69 | +| 8.3 Data and Information Protection ..... | 70 | +| 8.4 System logging..... | 70 | +| 8.4.1 Introduction ..... | 70 | +| 8.4.2 Security log format and related log fields ..... | 70 | +| 8.4.3 Authenticated Time Stamping..... | 71 | +| 8.4.4 Network Security and System Security Events..... | 72 | +| 8.4.5 Application Security Events..... | 74 | +| 8.4.6 Data Access Security Events..... | 75 | +| 8.4.7 Account and Identity Security Events..... | 77 | +| 8.4.8 General Security Events ..... | 78 | +| 8.4.9 Void | 80 | + +| | | +|---------------------------------------------------------------------------------------|-----| +| 9 Software security evaluation for O-RAN architecture elements..... | 80 | +| 9.1 Overview ..... | 80 | +| 9.2 Open-Source Software Component Analysis..... | 80 | +| 9.3 Binary Static Analysis..... | 80 | +| 9.4 Software Bill of Materials (SBOM)..... | 80 | +| 9.4.1 SBOM Signature ..... | 80 | +| 9.4.2 SBOM Data Fields ..... | 81 | +| 9.4.3 SBOM Format..... | 83 | +| 9.4.4 SBOM Depth..... | 84 | +| 9.4.5 Void | 84 | +| 9.4.6 SBOM Version Verification..... | 84 | +| 9.4.7 Void | 85 | +| 9.4.8 SBOM Presence ..... | 85 | +| 9.4.9 SBOM Vulnerabilities Field..... | 86 | +| 9.4.10 Void | 87 | +| 9.5 Software Image Signing and Verification ..... | 87 | +| 9.5.1 Void | 87 | +| 9.5.2 Software Signature Verification..... | 87 | +| 10 ML security validation for O-RAN system..... | 88 | +| 10.1 Overview ..... | 88 | +| 10.2 ML Data Poisoning ..... | 88 | +| 11 Security tests of O-RAN interfaces ..... | 88 | +| 11.1 FH | 88 | +| 11.1.1 Overview ..... | 88 | +| 11.1.2 Open Fronthaul Point-to-Point LAN Segment..... | 88 | +| 11.1.3 M-Plane ..... | 91 | +| 11.1.4 U-Plane..... | 102 | +| 11.1.5 S-Plane ..... | 104 | +| 11.2 Y1 | 113 | +| 11.2.1 Y1 Authenticity ..... | 113 | +| 11.2.2 Y1 confidentiality, integrity, and replay protection ..... | 114 | +| 11.2.3 Y1 Authorization..... | 115 | +| 11.3 O1 | 116 | +| 11.3.1 O1 Authenticity ..... | 116 | +| 11.3.2 O1 confidentiality, integrity and replay protection ..... | 118 | +| 11.3.3 O1 Interface Network Configuration Access Control Model (NACM) Validation..... | 119 | +| 11.4 O2 | 121 | +| 11.4.1 O2 Authenticity ..... | 121 | +| 11.4.2 O2 confidentiality, integrity and replay protection ..... | 122 | +| 11.4.3 O2 Authorization..... | 123 | +| 11.5 E2 | 124 | +| 11.5.1 E2 confidentiality, integrity and replay protection..... | 124 | +| 11.5.2 E2 Authenticity ..... | 125 | +| 11.6 A1 | 129 | +| 11.6.1 A1 Authenticity ..... | 129 | +| 11.6.2 A1 confidentiality, integrity and replay protection ..... | 131 | +| 11.6.3 A1 Authorization..... | 131 | +| 11.7 R1 | 133 | +| 11.7.1 R1 Authenticity ..... | 133 | +| 11.7.2 R1 confidentiality, integrity and replay protection ..... | 134 | +| 11.7.3 R1 Authorization..... | 135 | +| 12 Security test of O-RU ..... | 136 | +| 12.1 Overview ..... | 136 | +| 12.2 SSH on M-Plane interface..... | 136 | +| 12.3 TLS on M-Plane interface ..... | 137 | + +| | | +|----------------------------------------------------------------------------------|-----| +| 12.4 Security functional requirements and test cases..... | 137 | +| 13 Security test of Near-RT RIC..... | 137 | +| 13.1 Overview..... | 137 | +| 13.2 Void 138 | | +| 13.3 Transactional APIs..... | 138 | +| 13.3.1 Introduction..... | 138 | +| 13.3.2 TLS for transactional APIs..... | 138 | +| 13.3.3 mTLS for transactional APIs..... | 138 | +| 13.3.4 OAuth 2.0 for transactional APIs..... | 139 | +| 13.4 Security test of Near-RT RIC OAuth 2.0 Resource Owner/Server..... | 140 | +| 13.4.1 Overview..... | 140 | +| 13.4.2 Near-RT RIC OAuth 2.0 Resource Owner/Server..... | 140 | +| 13.5 Security test of Near-RT RIC OAuth 2.0 client..... | 140 | +| 13.5.1 Overview..... | 140 | +| 13.5.2 Near-RT RIC OAuth 2.0 client..... | 140 | +| 14 Security test of xApps..... | 141 | +| 14.1 Overview..... | 141 | +| 14.2 xApp Signing and Verification..... | 141 | +| 14.3 xAppID..... | 141 | +| 14.3.1 xApp ID format check..... | 141 | +| 14.3.2 xApp ID in xApp instance Certificate..... | 142 | +| 15 Security test of Non-RT RIC..... | 143 | +| 15.1 Overview..... | 143 | +| 15.2 Non-RT RIC..... | 143 | +| 15.2.1 Non-RT RIC OAuth 2.0 Resource Owner/Server..... | 143 | +| 15.2.2 Non-RT RIC OAuth 2.0 Client..... | 144 | +| 15.2.3 Non-RT RIC Framework OAuth 2.0..... | 144 | +| 15.3 R1 interface..... | 145 | +| 15.4 A1 interface..... | 145 | +| 16 Security test of rApps..... | 145 | +| 16.1 Overview..... | 145 | +| 16.2 rApp Signing and Verification..... | 145 | +| 16.3 rApp Authorization..... | 145 | +| 16.3.1 rApp OAuth 2.0 Client..... | 145 | +| 17 Security test of SMO..... | 146 | +| 17.1 Overview..... | 146 | +| 17.2 Void 147 | | +| 17.3 SMO 147 | | +| 17.3.1 SMO OAuth 2.0 Resource Owner/Server..... | 147 | +| 17.3.2 SMO OAuth 2.0 Client..... | 147 | +| 17.3.3 SMO mTLS for mutual authentication..... | 148 | +| 17.4 SMO Internal Communications..... | 148 | +| 17.4.1 TLS for SMO Internal Communications..... | 148 | +| 17.4.2 mTLS for SMO Internal Communications – SMO Functions..... | 149 | +| 17.5 SMO External Interfaces..... | 150 | +| 17.5.1 TLS for SMO External Interfaces..... | 150 | +| 17.5.2 mTLS for SMO External Interfaces..... | 150 | +| 17.5.3 SMO Framework OAuth 2.0 Resource Owner/Server for External Interface..... | 151 | +| 17.5.4 SMO Functions OAuth 2.0 Client..... | 151 | +| 17.6 SMO Logging..... | 152 | +| 17.6.1 TLS for SMO Logging Export..... | 152 | +| 17.6.2 mTLS for SMO Logging Export..... | 152 | +| 18 Security test of O-Cloud..... | 153 | +| 18.1 Overview..... | 153 | + +| | | | +|---------|---------------------------------------------------------------------------------------------|-----| +| 18.2 | Void | 153 | +| 18.3 | O-Cloud virtualization layer | 153 | +| 18.3.1 | Secure authentication (positive case) | 153 | +| 18.3.2 | Secure authentication (negative case) | 154 | +| 18.3.3 | Secure authorization (positive case) | 155 | +| 18.3.4 | Secure authorization (negative case) | 155 | +| 18.3.5 | Validate network connections allowed by network policies | 156 | +| 18.3.6 | Validate network connections not allowed by network policies | 157 | +| 18.3.7 | Validate network connections from outside the allowed network ranges | 158 | +| 18.3.8 | Exploitation of O-Cloud component vulnerabilities | 158 | +| 18.3.9 | Identification and remediation of insecure configuration settings | 159 | +| 18.3.10 | Validation of logging and monitoring for security incidents | 160 | +| 18.3.11 | O-Cloud Privilege Escalation Prevention | 160 | +| 18.3.12 | O-Cloud mutual authentication | 161 | +| 18.3.13 | O-Cloud authorization | 162 | +| 18.4 | Application deployment by O-Cloud | 163 | +| 18.4.1 | Verification of Application artifacts with valid signature by O-Cloud during deployment | 163 | +| 18.4.2 | Verification of Application artifacts with incorrect signature by O-Cloud during deployment | 164 | +| 18.5 | Resource Management and enforcement in O-Cloud | 165 | +| 18.5.1 | O-Cloud Resource Consumption Limit Enforcement | 165 | +| 18.5.2 | O-Cloud Storage Volume Limit Enforcement | 166 | +| 18.5.3 | O-Cloud CPU Overcommit Prevention | 167 | +| 18.5.4 | O-Cloud Memory Overcommit Prevention | 168 | +| 18.5.5 | O-Cloud Network Overcommit Prevention | 170 | +| 18.5.6 | O-Cloud Storage Overcommit Prevention | 171 | +| 18.6 | Secure Update | 172 | +| 18.6.1 | O-Cloud Infrastructure Software Package Integrity - Positive | 172 | +| 18.6.2 | O-Cloud Infrastructure Software Package Integrity Failure – Negative | 173 | +| 18.6.3 | Secure Update procedure for O-Cloud Platform – Positive | 174 | +| 18.6.4 | Secure Update failure for O-Cloud Platform – Negative | 175 | +| 18.7 | Secure Storage | 177 | +| 18.7.1 | Sensitive data protection in O-Cloud | 177 | +| 18.7.2 | Secure data deletion in O-Cloud | 178 | +| 18.7.3 | Data isolation in VM/Container reallocation | 179 | +| 18.8 | Chain of trust | 180 | +| 18.8.1 | Chain of Trust verification in static O-Cloud SW | 180 | +| 18.8.2 | Chain of Trust verification of dynamic O-Cloud SW | 181 | +| 18.9 | Secure time synchronization for O-Cloud | 183 | +| 19 | Security test of VNF/CNF | 184 | +| 19.1 | Overview | 184 | +| 19.2 | Executive environment protection | 184 | +| 19.3 | Signature validation during App image onboarding | 185 | +| 19.4 | Application image deployment security | 186 | +| 20 | Security tests of Common Application Lifecycle Management | 187 | +| 20.1 | Overview | 187 | +| 20.2 | Application package | 187 | +| 20.2.1 | Application package signature verification | 187 | +| 20.2.2 | Minimum Requirements | 187 | +| 20.2.3 | App Package Change Log | 188 | +| 20.3 | Secure Decommissioning | 189 | +| 20.3.1 | Post-Decommission Report | 189 | +| 20.3.2 | Trust Artifact Revocation | 190 | +| 21 | Security test of O-CU-CP | 190 | +| 21.1 | Overview | 190 | +| 21.2 | O-CU-CP 3GPP specific security functional requirements and test cases | 191 | + +| | | +|----------------------------------------------------------------------------------|-----| +| 21.3 O-RAN specific security functional requirements and test cases ..... | 191 | +| 22 Security test of O-CU-UP ..... | 191 | +| 22.1 Overview ..... | 191 | +| 22.2 O-CU-UP 3GPP specific security functional requirements and test cases ..... | 191 | +| 22.3 O-RAN specific security functional requirements and test cases ..... | 192 | +| 23 Security test of O-DU ..... | 192 | +| 23.1 Overview ..... | 192 | +| 23.2 O-DU 3GPP specific security functional requirements and test cases ..... | 192 | +| 23.3 O-RAN specific security functional requirements and test cases ..... | 192 | +| 24 End-to-End security test cases ..... | 193 | +| 24.0 Overview ..... | 193 | +| 24.1 3GPP Security Assurance Specification (SCAS) ..... | 193 | +| 24.2 DoS, fuzzing and blind exploitation test ..... | 198 | +| 24.2.1 S-Plane ..... | 199 | +| 24.2.2 C-Plane ..... | 202 | +| 24.2.3 A1 interface ..... | 207 | +| 24.2.4 O-Cloud ..... | 211 | +| 25 Security test of Shared O-RU ..... | 213 | +| 25.1 Overview ..... | 213 | +| 25.2 Shared O-RU test cases ..... | 213 | +| 25.2.1 mTLS for mutual authentication ..... | 213 | +| 25.2.2 NACM Authorization ..... | 213 | +| 25.2.3 TLS across Open Fronthaul ..... | 214 | +| 25.2.4 Reject Password-based authentication ..... | 215 | +| Annex A (informative): Example of Security Testing Tools / Toolset ..... | 217 | +| Annex B (informative): Template of test report ..... | 218 | +| Revision history ..... | 221 | +| Annex (informative): Change History ..... | 226 | + +# --- List of figures + +| | | +|-------------------------------------------------------------------------|-----| +| Figure 5-1: Logical Architecture of O-RAN system..... | 17 | +| Figure 6-1: Access Token request ..... | 32 | +| Figure 6-2: Service request ..... | 32 | +| Figure 24-1: S-Plane O-DU Test setup..... | 200 | +| Figure 24-2: S-Plane PTP Unexpected Input Test Setup..... | 201 | +| Figure 24-3: C-Plane eCPRI DoS Attack Test Setup ..... | 202 | +| Figure 24-4: C-Plane eCPRI Unexpected Input Test Setup ..... | 204 | +| Figure 24-5: C-Plane eCPRI DoS Attack on O-RU Test Setup ..... | 205 | +| Figure 24-6: C-Plane eCPRI Unexpected Input on O-RU Test Setup ..... | 206 | +| Figure 24-7: Near-RT RIC A1 Interface DoS Attack Test Setup ..... | 208 | +| Figure 24-8: Near-RT RIC A1 Interface Unexpected Input Test Setup ..... | 209 | +| Figure 24-9: Near-RT RIC A1 Vulnerability Assessment Test Setup ..... | 210 | +| Figure 24-10: O-Cloud side-channel DoS attack Test Setup ..... | 212 | + +# --- List of tables + +| | | +|----------------------------------------------------------------------------------------------------------------|-----| +| Table 5-1 Test and measurement equipment list ..... | 19 | +| Table 8-1 Test and measurement equipment list ..... | 71 | +| Table 8-2 Test and measurement equipment list ..... | 71 | +| Table 9-1: Minimum set of data fields for SPDX [12]..... | 82 | +| Table 9-2: Minimum set of data fields for CycloneDX [13]..... | 82 | +| Table 9-3: Minimum set of data fields for SWID [13]..... | 82 | +| Table 11-1: Scenarios to be executed ..... | 89 | +| Table 11-2: Expected results ..... | 90 | +| Table 11-3: Scenarios to be executed ..... | 91 | +| Table 11-4: Expected results ..... | 91 | +| Table 24-1: List of SCAS Test Cases for NR and applicable technology from Clause 4.2.2 of 3GPP TS 33.511 ..... | 194 | +| Table 24-2: List of SCAS Test Cases for LTE and applicable technology from Clause 4.2.2 of 3GPP TS 33.216..... | 196 | +| Table 24-3: End-to-end test cases and applicable technology..... | 199 | +| Table Annex A-1: List of sample open source security testing tools/toolset..... | 217 | + +# --- Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document provides description of the Security Tests, which validate security functions and configurations per security and security protocols requirements and are based on the priority of the risk analysis for O-RAN systems. + +# --- 2 References + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN ALLIANCE TS: "O-RAN Architecture Description" +- [2] O-RAN ALLIANCE TS: "O-RAN Security Protocols Specifications" +- [3] void +- [4] O-RAN ALLIANCE TS: "O-RAN End-to-End Test Specification" +- [5] O-RAN ALLIANCE TS: "O-RAN Security Requirements and Controls Specifications" +- [6] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications" +- [7] 3GPP TS 33.117: "Catalogue of General Security Assurance Requirements" +- [8] 3GPP TS 33.511: "Security Assurance Specification (SCAS) for the next generation Node B (gNodeB) network product class" +- [9] 3GPP TS 33.216: "Security Assurance Specification (SCAS) for the Evolved Node B (eNodeB) network product class" +- [10] Openssh Security Vulnerabilities, [https://www.cvedetails.com/vulnerability-list/vendor\\_id-97/product\\_id-585/Openbsd-Openssh.html](https://www.cvedetails.com/vulnerability-list/vendor_id-97/product_id-585/Openbsd-Openssh.html) +- [11] "IEEE Standard for Local and Metropolitan Area Networks--Port-Based Network Access Control," in IEEE Std 802.1X-2020 (Revision of IEEE Std 802.1X-2010 Incorporating IEEE Std 802.1Xbx-2014 and IEEE Std 802.1Xck-2018), vol., no., pp.1-289, 28 Feb. 2020, doi: 10.1109/IEEESTD.2020.9018454 +- [12] "Generating Software Bills of Materials (SBOMs) with SPDX at Microsoft", +- [13] NTIA: "The Minimum Elements For a Software Bill of Materials (SBOM)", [https://www.ntia.gov/sites/default/files/publications/sbom\\_minimum\\_elements\\_report\\_0.pdf](https://www.ntia.gov/sites/default/files/publications/sbom_minimum_elements_report_0.pdf) +- [14] IETF RFC 8341: "Network Configuration Access Control Model" +- [15] O-RAN ALLIANCE TR: "O-RAN O-Cloud Security Analysis Report" + +- [16] O-RAN ALLIANCE TR: "O-RAN Near-RT RIC and xApp Security Analysis Report" +- [17] O-RAN ALLIANCE TR: "O-RAN Non-RT RIC Security Analysis Report" +- [18] IETF RFC 6749: "The OAuth 2.0 Authorization framework" +- [19] IETF RFC 7519: "JSON Web Token (JWT)" +- [20] IETF RFC 7515: "JSON Web Signature (JWS)" +- [21] O-RAN ALLIANCE TS: "O-RAN WG4 Management Plane Specification" +- [22] O-RAN ALLIANCE TS: "O-RAN Use Cases Detailed Specification" +- [23] 3GPP TS 33.523: "5G Security Assurance Specification (SCAS); Split gNB product classes" +- [24] void +- [25] 3GPP TS 33.501: "Security architecture and procedures for 5G system" +- [26] O-RAN ALLIANCE TS: "O-RAN WG4 Control, User and Synchronization Plane Specification" +- [27] O-RAN ALLIANCE TS: "O-RAN Near-RT RIC Architecture" +- [28] O-RAN ALLIANCE TS: "O-RAN E2 Application Protocol (E2AP)" +- [29] O-RAN ALLIANCE TS: "O-RAN E2 Interface Test Specification" +- [30] IETF RFC 9562: "Universally Unique IDentifiers (UUIDs)" + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document, a non-specific reference implicitly refers to the latest version of that document in Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] Service Name and Transport Protocol Port Number Registry, +- [i.2] SPDX, +- [i.3] CycloneDX, +- [i.4] NIST IR 8060: "Guidelines for the Creation of Interoperable Software Identification (SWID) Tags", +- [i.5] O-RAN ALLIANCE TR: "O-RAN Security Threat Modeling and Risk Assessment" + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For definitions of the security terms Attack, Attack surface, Risk, Security control, Technical control, Threat, and Vulnerability used in this document, refer to [i.5]. + +For the purposes of the present document, the terms and definitions given in 3GPP TR21.905 [6], O-RAN Architecture Description [1], and the following in this clause apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR21.905 [6] and O-RAN Architecture Description [1]. + +**A1:** Interface between non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**E2:** Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. + +**RAN:** Generally referred as Radio Access Network. In terms of this document, any component below Near-RT RIC per O-RAN architecture, including O-CU/O-DU/O-RU. + +**Overcommitting resources:** It refers to the practice of allocating or promising more resources than are physically available on a system. This concept is commonly used in virtualized and cloud environments. The idea behind overcommitment is to optimize resource utilization based on the observation that not all applications will use their allocated resources to the maximum at the same time. Here's a breakdown of overcommitment for different resources: + +- **CPU Overcommitment:** More virtual CPUs (vCPUs) are allocated to VMs or Containers than there are physical CPU cores available on the host. +- **Memory Overcommitment:** The total memory allocated to VMs or Containers exceeds the physical RAM available on the host. +- **Storage Overcommitment:** More storage space is allocated to VMs or Containers than the actual available capacity on the storage device. +- **Network Overcommitment:** More bandwidth is promised to VMs or Containers than the physical network can provide. + +**Overcommit ratios:** It defines the extent to which resources can be overallocated compared to the actual available physical resources. + +- **CPU Overcommit Ratio:** If you have a CPU overcommit ratio of 2:1, it means you can allocate twice the number of virtual CPUs (vCPUs) as there are physical CPU cores on the host. For instance, if a server has 8 physical CPU cores, you could allocate 16 vCPUs across various VMs or Containers. +- **Memory Overcommit Ratio:** If you have a memory overcommit ratio of 1.5:1, it means you can allocate 1.5 times the amount of virtual RAM as there is physical RAM on the host. For a server with 64GB of physical RAM, you could allocate a total of 96GB of RAM across various VMs or Containers. + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given 3GPP TR21.905[6], O-RAN Architecture Description[1], and the following in this clause apply. A abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR21.905[6] and O-RAN Architecture Description[1]. + +AI/ML Artificial Intelligence / Machine Learning + +CMS/PKCS#7/CAaES Cryptographic Message Syntax/Public-Key Cryptography Standards/CMS Advanced Electronic Signatures + +CNF Cloud Native Function + +COT Chain of Trust + +CSI Channel State Information + +CSR Certificate Signing Request + +DTLS Datagram Transport Layer Security + +DUT Device Under Test + +eCPRI Enhanced Common Public Radio Interface + +FTP File Transfer Protocol + +FTPS File Transfer Protocol Secure + +gRPC a cross-platform remote procedure call (RPC) framework + +IPSEC Internet Protocol Security + +JSF JSON Signature Format + +JSON JavaScript Object Notation + +JWT JSON Web Token + +JWS JSON Web Signature + +KPI Key Performance Indicator + +mTLS Mutual Transport Layer Security + +NACM Network Configuration Access Control Model + +NETCONF Network Configuration Protocol + +NFO Network Function Orchestration + +NTIA National Telecommunications and Information Administration - United States Department of Commerce + +OAuth Open Authentication + +PDCCP Packet Data Convergence Protocol + +PNF Physical Network Function + +PTP Precision Timing Protocol + +RBAC Role-based Access Control + +REST Representational state transfer +RDF Resource Description Format +RIC O-RAN RAN Intelligent Controller +RoT Root of Trust +SBOM Software Bill of Materials +SDLC Software Development Lifecycle +SSH Secure Shell +SUT System Under Test +TLS Transport Layer Security +VNF Virtualized Network Function +WAS Web Application Security +XML Extensible Markup Language +YAML Ain't Markup Language + +# --- 4 Objectives and scope + +This security test specification is focused on: + +- Validating the implementation of security requirements and security protocols specified in [5] and [2]. +- Emulating security attacks against the O-RAN component(s), interfaces, and the system to measure the robustness of the O-RAN system and the service impact(s). +- Validating the effectiveness of the security mitigation method(s) to protect the O-RAN system and the services it offers. + +This security test specification is based on the priority of the risk assessment of the O-RAN security threats and security requirements of the O-RAN system. + +# 5 Testing methodology and configuration + +This clause describes the common testing methods and configurations used in the subsequent clauses. To ensure fair and comparable test results among various test campaigns, consistent test setups shall be utilized. This security test specification describes the test conditions, methodologies, and procedures, so that the test can be reproduced if needed, and the test results can be used for comparison or reference purposes. + +## 5.1 DUT / SUT + +![Figure 5-1: Logical Architecture of O-RAN system. The diagram shows the O-RAN architecture elements and interfaces. At the top is the Service Management and Orchestration Framework (SMO) containing the Non-Real Time RIC. Below it is the Near-Real Time RIC, which connects to O-eNB and O-CU-CP. O-CU-CP connects to O-CU-UP, which in turn connects to O-DU, O-RU, and O-Cloud. The diagram also shows various interfaces: O1, O2, A1, E1, E2, F1-c, F1-u, X2-c, X2-u, NG-u, Xn-c, Xn-u, NG-c. A legend indicates that black lines represent 3GPP interfaces and green lines represent O-RAN interfaces. The Open FH M-Plane is shown as a green line connecting O-eNB to O-Cloud. The Open FH CUS-Plane is shown as a green line connecting O-CU-CP to O-Cloud.](2f87e3619117952a875a1e85146094da_img.jpg) + +Figure 5-1: Logical Architecture of O-RAN system. The diagram shows the O-RAN architecture elements and interfaces. At the top is the Service Management and Orchestration Framework (SMO) containing the Non-Real Time RIC. Below it is the Near-Real Time RIC, which connects to O-eNB and O-CU-CP. O-CU-CP connects to O-CU-UP, which in turn connects to O-DU, O-RU, and O-Cloud. The diagram also shows various interfaces: O1, O2, A1, E1, E2, F1-c, F1-u, X2-c, X2-u, NG-u, Xn-c, Xn-u, NG-c. A legend indicates that black lines represent 3GPP interfaces and green lines represent O-RAN interfaces. The Open FH M-Plane is shown as a green line connecting O-eNB to O-Cloud. The Open FH CUS-Plane is shown as a green line connecting O-CU-CP to O-Cloud. + +**Figure 5-1: Logical Architecture of O-RAN system** + +Figure 5-1 illustrates the O-RAN architecture elements, interfaces, and overall system. + +As specified in [1], the following O-RAN architecture elements and interfaces shall be the DUT or SUT addressed in this security test specification. + +### O-RAN architecture elements: + +- Network functions and applications + - Service Management and Orchestration (SMO) + - Non-RT RIC and rApps + - Near-RT RIC and xApps + - O-CU-CP/UP + - O-DU + - O-RU + - O-eNB + +- Cloud computing platform + - O-Cloud comprising a collection of physical infrastructure nodes that meet O-RAN requirements to host the relevant O-RAN functions (such as Near-RT RIC, O-CU-CP, O-CU-UP, and O-DU), the supporting software components (such as Operating System, Virtual Machine Monitor, Container Runtime, etc.) and the appropriate management and orchestration functions. + +### Maintained interfaces by O-RAN: + +- A1 Interface between Non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. +- O1 Interface connecting the SMO to the Near-RT RIC, one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. +- O2 Interface between the SMO and the O-Cloud +- E2 Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, one or more O-DUs, and one or more O-eNBs. +- Open Fronthaul CUS-Plane Interface between O-RU and O-DU +- Open Fronthaul M-Plane Interface between O-RU and O-DU as well as between O-RU and SMO + +During the test execution, only one DUT or SUT shall be tested at the same time. The rest of elements involved in the test setup should be simulated or real, according to the test preconditions, but only the DUT or SUT shall be considered under evaluation. + +## 5.2 Test Setup + +Please refer to the security test cases listed in the following clauses for their specific test setups. + +## 5.3 Test and measurement equipment and tools + +The following table lists test and measurement equipment required for the security tests in this document. + +**Table 5-1 Test and measurement equipment list** + +| Test tool | Description | +|---------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Commercial UE and/or UE emulator |

    A commercial UE or UE emulator shall be used to establish stateful end-to-end connection and to generate or receive data traffic.

    The commercial UE used in this context as a test tool is typically a UE which is designed for commercial or testing applications with certain test and diagnostic functions enabled for test and measurements purposes. Such test and diagnostic functions should not affect the performance.

    This commercial UE requires an (emulated) SIM card which is pre-provisioned with subscriber profiles. A UE emulator or multiple commercial UEs can be used in multi-UE test scenarios requiring multiple UEs sessions. The UE shall connect to the SUT either via RF cables or via an over the air (OTA) connection. In a lab environment, the UE shall be placed inside an RF shielded box/room to avoid interference from external signals.

    A logging tool connected to the UE shall be used to capture measurements and KPI logs for test validation and reporting.

    | +| 4G/5G Core or Core emulator | A 4G/5G core or core emulator shall be used to terminate 4G/5G NAS sessions, and to support core network procedures required for RAN (SUT) testing. 4G/5G core or core emulator shall support end-to-end connection and data transfer between Application server and commercial UE/UE emulator. | +| Application (traffic) server | An application (traffic) server shall be used as an endpoint for generation and/or termination of data traffic streams to/from commercial UE(s)/UE emulator. The application server shall be capable of generating data traffic for the services under test. | +| Network impairment emulator | A network impairment emulator shall be used for tests which require insertion of impairment (packet delay and/or jitter) at the network interface (e.g. OpenFH). | +| Packet generation tool / DoS emulator | A packet generation tool / Denial of Service (DoS) emulator shall be used for DoS traffic generation of security tests. The tool shall support crafting network traffic over the following network protocols: Ethernet, IP, UDP, TCP, PTP, eCPRI, TLS, HTTP/HTTPS. | +| Packet capture tool | A packet capture tool shall be used to capture samples of data traffic for validation, analysis, and troubleshooting. It may be used to capture samples of legitimate traffic, which then may be used as templates for fuzzing attacks. The tool shall support capturing network traffic over the following network protocols: Ethernet, IP, UDP, TCP, PTP, eCPRI, TLS, QUIC, HTTP/HTTPS. | +| Network tap | A network tap shall be a hardware or software device which provides access and visibility to the data flowing across a computer network. | +| Port scanner |

    A protocol scanner shall be used for probing network protocols and services. It shall be able to detect open ports. It shall be able to detect what service is exposed as active on the open port.

    Port scanners commonly come with built-in database of services. Service detection can use numerous built-in probes for querying various services. In practice, port scanners are often used for service detection.

    | +| Fuzzing tool | A protocol fuzzing tool shall be used for unexpected protocol input generation of security tests. The tool shall support mutating and replaying of captured network traffic over the following network protocols: Ethernet, IP, UDP, TCP, PTP, eCPRI, TLS, HTTP/HTTPS. | +| Vulnerability scanning tool | A vulnerability scanning tool shall be used for blind exploitation of well-known vulnerabilities during security tests. The tool may rely on cyclically updated database of known vulnerabilities based on Common Vulnerabilities and Exposures (CVE) and should support scanning network services running on TCP/IP stack of protocols. | + +| | | +|-----------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| NFV benchmarking and resource exhaustion tool | A Network Function Virtualization (NFV) tool shall be used for O-Cloud system performance measurement and resource exhaustion type of DoS attack generation. This tool shall be capable of supporting any types of O-Cloud environment (public or private) with testing VNF(s) and/or CNF(s). | +| SSH audit tool | An SSH audit tool shall be used to verify the following properties: version of protocol, cipher suites, and known vulnerabilities in server and client SSH software. | +| TLS scanning tool | A TLS scanning tool shall be used to verify the following properties: version of protocol, cipher suites, and known vulnerabilities in server TLS software. | +| DTLS scanning tool | A DTLS scanning tool shall be used to verify the following properties: version of protocol, cipher suites, and known vulnerabilities in server DTLS software. | +| IKE scanning tool | An IKE scanning tool shall be used to verify the following properties: version of protocol, cipher suites, and known vulnerabilities in server IPsec software. | +| Software image signing tool | A Software image signing tool shall be used to digitally sign and verify the software image, e.g. xApps or O-RAN component delivered by a software producer/provider. | + +## 5.4 Test report + +Tests should be described in the test report with sufficient detail to allow the tests to be reproducible by different parties and to enable comparison. A template for a complete test report is found in Annex B and may be used. Photos and screenshots should also be taken as part of the test report to illustrate the test environment. Additional parameters are specified in the description of each test in the subsequent clauses. + +## 5.5 Assumptions + +All threat IDs in the present document are referenced from O-RAN Security Threat Modeling and Risk Assessment [i.5]. + +## 5.6 Testing tools + +The tools outlined in this clause represent a selection of commonly used resources for testing processes. It's important to emphasize that this list is not exhaustive. Testers are encouraged to use additional tools as needed for comprehensive and effective testing, ensuring they meet the standards and requirements set forth in this test plan. + +### 1. Packet capture and traffic analysis tools: + +- Wireshark: Wireshark is a widely used open-source network protocol analyser that can capture and analyse network traffic. It enables you to inspect packets for confidentiality, integrity, and replay-related issues. You can also verify authentication mechanisms and analyse access control measures. +- tcpdump: tcpdump is a command-line packet analyser available on various operating systems. It captures network traffic and can save it to a file for later analysis. tcpdump offers powerful filtering capabilities to capture specific traffic based on criteria such as source/destination IP addresses, protocols, or ports. +- Netscout Sniffer: Netscout Sniffer is a commercial network analysis tool that offers real-time packet capture and analysis capabilities. It provides comprehensive visibility into network traffic and offers advanced features for troubleshooting and performance analysis. + +- Colasoft Capsa: Colasoft Capsa is a network analyser designed for network monitoring and troubleshooting. It captures and analyses network traffic, providing insights into protocols, applications, and potential security issues. Capsa offers both real-time and post-capture analysis. +- Tcpreplay: Tcpreplay is an open-source tool used for replaying captured network traffic. It allows you to replay network packets from a previously captured pcap file, simulating real-world traffic scenarios. While its primary purpose is not security testing, tcpreplay can be utilized as a tool in security testing efforts, particularly for testing the replay and handling of network packets. + +### 2. Traffic Generation Tools: + +- Scapy: Scapy is a powerful Python-based tool that can create, manipulate, and send custom network packets. It allows to generate and replay packets on an interface to test for replay vulnerabilities. +- Hping: Hping is a command-line tool that can send custom packets and perform various network-related activities. It can be used to generate replayed packets on an interface for testing purposes. + +#### 3. Scripting and Automation Tools to develop custom test scripts: + +- Python: Python scripting language provides libraries (e.g., socket, scapy) that allow you to write custom scripts to generate and replay packets on an interface. +- Bash scripting: Bash scripting can be utilized to automate the process of capturing packets and replaying them on an interface. + +## 4. Network Emulation Tools: + +- GNS3: GNS3 is a network emulation tool that allows you to simulate complex network topologies. It can be used to create a virtual environment with RAN E1 interfaces, generate traffic, and simulate replay attacks for testing purposes. + +## 5. Network performance tools: + +- iPerf3: iPerf3 is an open-source tool for network performance testing and measurement. While it is primarily focused on network performance evaluation, it can also be utilized as a tool to indirectly assess certain aspects of security, such as bandwidth availability and network congestion. + +## 6. Traffic Manipulation Tools: + +- Burp Suite: Burp Suite is a web application security testing tool that can intercept, modify, and replay network traffic. While it is primarily designed for web applications, it allows to test the integrity, confidentiality, and authenticity of data transmitted over an interface. + +## 7. Vulnerability assessment tools + +- Nessus: Nessus is a popular vulnerability assessment tool that can scan an interface for known security vulnerabilities and misconfigurations. It can help identify potential weaknesses related to confidentiality, integrity, replay attacks, and access control. +- OpenVAS: OpenVAS (Open Vulnerability Assessment System) is an open-source vulnerability scanner that can perform security audits on security protocols implementations. It can detect vulnerabilities, misconfigurations, and compliance issues, helping ensure that an interface adheres to security best practices and standards. + +## 8. Security Information and Event Management (SIEM) Tools: + +- SIEM tools like Splunk or ELK (Elasticsearch, Logstash, Kibana) can help collect and analyse security events and logs related to the O-RAN components and interfaces. They can assist in identifying potential security incidents, monitoring access control, and detecting anomalies. + +## 9. IPsec tool + +- OpenSwan is an open-source implementation of the IPsec (Internet Protocol Security) protocols suite. It provides tools and libraries for setting up and managing IPsec connections, which can be used to test the confidentiality, integrity, replay, authenticity, and access control of an interface. Here's how OpenSwan can be used for testing: + - Confidentiality and Integrity: + - OpenSwan allows to configure IPsec tunnels with encryption algorithms (e.g., AES) and integrity algorithms (e.g., HMAC-SHA256). By setting up IPsec connections using OpenSwan, it is possible to verify the confidentiality and integrity of data transmitted over an interface. + - Replay Attack: + - OpenSwan supports anti-replay mechanisms, which protect against replay attacks by assigning sequence numbers to IPsec packets. These mechanisms can be tested to ensure that replayed packets are detected and rejected. + - Authenticity: + - OpenSwan supports authentication mechanisms such as pre-shared keys or digital certificates, which ensure the authenticity of IPsec connections. Testing can be performed to verify the proper authentication of an interface. + - Access Control: + - OpenSwan allows to configure IPsec security policies, including source/destination IP address filtering, protocol filtering, and port filtering. These policies can be tested to ensure that only authorized traffic is allowed through an interface. +- StrongSwan: Another open-source IPsec-based VPN solution that includes testing capabilities. It allows you to configure and simulate IPsec connections, test authentication methods, and perform security checks. + +#### 10. Cryptographic operations testing tools + +- Hashing Tools: Hashing tools such as sha256sum, can be used to calculate hash values of transmitted data. By comparing the computed hash values at the source and destination, you can verify the integrity of the data. + +**Cryptographic Libraries:** Cryptographic libraries, such as Bouncy Castle, provide APIs and tools for implementing and testing integrity protection mechanisms. These libraries offer functions to generate integrity checks (e.g., MAC) and validate the integrity of received data. + +--- + +## 6 Security Protocol & APIs Validation + +### 6.1 Overview + +This clause contains test cases to validate implementation of security protocols against O-RAN security requirements in [2] and [5]. + +### 6.2 SSH Server & Client + +**Requirement Name:** Network Security Protocol - SSH + +**Requirement Reference:** Clause 4.1, O-RAN Security Protocols Specifications [2] + +**Requirement Description:** Robust protocol implementation with adequately strong cipher suites is being required for SSH + +**Threat References:** T-O-RAN-05 + +**DUT/s:** SMO, O-DU, O-RU + +**Test Name:** TC\_SSH\_Server\_and\_Client\_Protocol + +**Purpose:** To verify implementation of the secure communication protocol SSH as specified in [2]. + +#### Procedure and execution steps + +##### Preconditions + +- Tool: SSH audit tool with capabilities as defined in clause 5.3 +- Testing of server configuration (DUT in the role of server): Network access to SSH server +- Testing of client configuration (DUT in the role of client): Access to configuration of SSH client + +##### Execution steps + +Testing of server configuration (DUT in the role of server): + +- Run SSH audit tool in server audit mode against target SSH server +- Compare the tool's output with the list of approved SSH protocol versions and algorithms (for host key, symmetric encryption, key exchange, and MACs) as defined by clause 4.1, O-RAN Security Protocols Specifications [2]. + +Testing of client configuration (DUT in the role of client): + +- Run SSH audit tool on target SSH client in client audit mode +- Compare the tool's output with the list of approved SSH protocol versions and algorithms (for host key, symmetric encryption, key exchange, and MACs) as defined by clause 4.1, O-RAN Security Protocols Specifications [2]. + +##### Expected results + +- All detected SSH protocol versions are explicitly allowed by [2], clause 4.1. +- All detected SSH algorithms (for host key, symmetric encryption, key exchange, and MACs) are explicitly allowed by [2], clause 4.1. + +**Expected format of evidence:** Report files produced by SSH audit tool and/or screenshots + +## 6.3 TLS + +**Requirement Name:** Network Security Protocol - TLS + +**Requirement Reference:** Clause 4.2, O-RAN Security Protocols Specifications [2] + +**Requirement Description:** Support TLS with protocol profiles + +**Threat References:** T-O-RAN-05 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_TLS\_Protocol + +**Purpose:** To verify implementation of the secure communication protocol TLS as specified in [2], clause 4.2. + +### Procedure and execution steps + +#### Preconditions + +- Tool: TLS scanning tool with capabilities as defined in clause 5.3 with client certificate(s) installed; +- DUT equipped with CA certificate that is a trust anchor for the client certificate(s) +- Network access to DUT with exposed TLS server + +#### Execution steps + +- Protocol scanning + - Run TLS scanning tool against DUT for detection of: + - TLS version + - Cipher suites + - Elliptic curves + - Certificate type + - Diffie-Hellman groups + - Compression methods + - Compare the test result/report with the list of approved TLS versions and profiles as defined by O-RAN Security Protocols Specifications [2], clause 4.2. +- Mutual Authentication + - Run TLS scanning tool with TLS v1.2 and valid client certificate against DUT with mutual authentication enabled to verify the establishment of the TLS session after successful authentication + - Run TLS scanning tool with TLS v1.2 and invalid client certificate (including but not limited to expired certificate, missing field certificate, untrusted CA signed certificate, ...) against DUT with mutual authentication enabled to verify the failed attempt of the TLS session establishment due to certificate validation + - Run TLS scanning tool with TLS v1.3 and valid client certificate against DUT with mutual authentication enabled to verify the establishment of the TLS session after successful authentication + - Run TLS scanning tool with TLS v1.3 and invalid client certificate (including but not limited to expired certificate, missing field certificate, untrusted CA signed certificate, ...) against DUT with mutual authentication enabled to verify the failed attempt of the TLS session establishment due to certificate validation + +**Expected results** + +- All supported TLS protocol versions are explicitly allowed by [2], clause 4.2. +- All detected TLS cipher suites, elliptic curves, Diffie-Hellman groups and compression methods are explicitly allowed by [2], clause 4.2. +- Mutual authentication support works with client certificates + +**Expected format of evidence:** Report files produced by TLS scanning tool and/or screenshots + +## 6.4 DTLS + +**Requirement Name:** Network Security Protocol - DTLS + +**Requirement Reference:** Clause 4.4, O-RAN Security Protocols Specifications [2] + +**Requirement Description:** Support DTLS + +**Threat References:** T-O-RAN-01 + +**DUT/s:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU + +**Test Name:** TC\_DTLS\_Protocol + +**Purpose:** To verify implementation of the secure communication protocol DTLS as specified in [2], clause 4.4. + +**Procedure and execution steps****Preconditions** + +- Tool: DTLS scanning tool with capabilities as defined in clause 5.3 +- Network access to DUT + +**Execution steps** + +- Run DTLS scanning tool against DUT for detection of: + - DTLS version + - Cipher suites + - Elliptic curves + - Certificate type + - Diffie-Hellman groups + - Compression methods +- Compare the test result/report with the list of approved DTLS versions and profiles as defined by Security Protocols Specification [2], clause 4.4. + +**Expected results** + +- All supported DTLS protocol versions are explicitly allowed by [2], clause 4.4. +- All detected DTLS cipher suites, elliptic curves, Diffie-Hellman groups and compression methods are explicitly allowed by [2], clause 4.4. + +**Expected format of evidence:** Report files produced by DTLS scanning tool and/or screenshots. + +## 6.5 IPsec + +### 6.5.1 IPsec security + +**Requirement Name:** Network Security Protocol - IPsec + +**Requirement Reference:** Clause 4.5, O-RAN Security Protocols Specifications [2] + +**Requirement Description:** Support IPsec tunnel mode with confidentiality, integrity, authentication, and anti-replay protection. + +**Threat References:** T-O-RAN-05 + +**DUT/s:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU + +**Test Name:** TC\_IPsec\_Security + +**Purpose:** To verify implementation of the secure communication protocol IPsec. + +#### Procedure and execution steps + +##### Preconditions + +- Tool: IKE scanning tool with capabilities as defined in clause 5.3 +- Network access to DUT + +##### Execution steps + +- Run IKE scanning tool against DUT for detection of: + - ESP Encryption Transforms + - ESP Authentication Transforms + - Diffie-Hellman groups + - Certificate type +- Compare the test result/report with the list of approved IPsec IKE versions, ESP Encryption Transforms, ESP Authentication Transforms and Diffie-Hellman groups as defined by O-RAN Security Protocols Specification [2], clause 4.5. + +##### Expected results + +- All detected IPsec IKE versions are explicitly allowed by [2], clause 4.5. +- All detected ESP Encryption Transforms, ESP Authentication Transforms and Diffie-Hellman groups are explicitly allowed by [2], clause 4.5. IKE version (v2) support with no older version(s) enabled. +- If certificates are used, their format is X.509v3 + +##### Expected format of evidence: + +- .pcap files capturing the IKE negotiations between the tool and the DUT. +- Report or output from the IKE scanning tool, specifically highlighting: + - Detected ESP Encryption Transforms. + - Detected ESP Authentication Transforms. + +- Detected Diffie-Hellman groups. +- Detected Certificate type. +- Screenshots from the IKE scanning tool showing scan results, especially the supported IKE version detected. +- If certificates are used, a sample or screenshot verifying the X.509v3 format. + +## 6.5.2 IKE Header Flags Fuzzing + +**Requirement Name:** Network Security Protocol - IPsec + +**Requirement Reference:** Clause 4.5, O-RAN Security Protocols Specifications [2] + +**Requirement Description:** Support IPsec tunnel mode with confidentiality, integrity, authentication, and anti-replay protection. + +**Threat References:** T-O-RAN-01 + +**DUT/s:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU + +**Test Name:** TC\_IKE\_HEADER\_FLAGS\_FUZZING + +**Purpose:** The purpose of this test is to verify the robustness of the IKEv2 server when faced with malformed IKE headers. Flags within the IKE header are intended to provide specific instructions or information about the message. By fuzzing these flags, we can identify potential vulnerabilities or flaws in the server's processing logic. + +### Procedure and execution steps + +#### Preconditions + +- A controlled environment with an IKEv2 server and a test client. +- Packet capture tool (e.g., Wireshark) for monitoring the traffic. +- Fuzzing tool or script to generate malformed IKE header flags. + +#### Execution steps + +1. Begin by starting the packet capture tool to record the test session. +2. Use the fuzzing tool or script to generate IKEv2 messages with the following malformed flags in the IKE header: + - **Initiator flag:** Flip this flag to see if the server can identify a message that isn't from an initiator. + - **Version flag:** Introduce an unsupported version. + - **Response flag:** Send messages that have this flag inappropriately set. + - **Combination of multiple flags:** Mix flags to generate completely unexpected combinations. +3. Send each of these malformed messages to the IKEv2 server individually, waiting for a response before sending the next. +4. Observe server reactions, looking specifically for any unhandled exceptions, crashes, or irregular behaviours. + +#### Expected Results + +- The IKEv2 server handles the malformed flags gracefully, either by rejecting the message or by ignoring the unexpected flag values. +- There is no crashes, hangs, or undefined behaviours. + +**Expected format of evidence** + +- Packet capture files (.pcap) showing the malformed flags sent and the server's responses. +- Server logs indicating the handling (or rejection) of the malformed messages. + +## 6.5.3 IKE Key Exchange Payload Fuzzing + +**Requirement Name:** Network Security Protocol - IPsec + +**Requirement Reference:** Clause 4.5, O-RAN Security Protocols Specifications [2] + +**Requirement Description:** Support IPsec tunnel mode with confidentiality, integrity, authentication, and anti-replay protection. + +**Threat References:** T-O-RAN-01 + +**DUT/s:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU + +**Test Name:** TC\_IKE\_KEY\_EXCHANGE\_PAYLOAD\_FUZZING + +**Purpose:** The purpose of this test is to examine the IKEv2 server's ability to manage corrupted or unexpected data within the Key Exchange (KE) payload. The KE payload carries the Diffie-Hellman public value. If the server is unable to handle malformed KE payloads, it might be susceptible to attacks or crashes. + +**Procedure and execution steps****Preconditions** + +- A controlled environment with an IKEv2 server and a test client. +- Packet capture tool (e.g., Wireshark) for monitoring the traffic. +- Fuzzing tool or script capable of generating malformed KE payloads. + +**Execution steps** + +1. Start the packet capture tool to ensure you record every detail of the test session. +2. Use your fuzzing tool or script to generate IKEv2 messages with the following specific manipulations in the KE payloads: + - Unexpected length: Prepare 10 distinct messages where the KE payload's declared length is longer or shorter than the actual payload. + - Corrupted data: Generate 10 messages introducing random bytes into the KE payload to see how the server handles non-standard values. + - Unsupported Diffie-Hellman groups: Create 5 messages attempting to initiate a key exchange using a DH group that is either deprecated or not supported by the server. + - Empty KE payload: Formulate 5 messages with an empty KE payload. +3. Sequentially send these 30 malformed messages to the IKEv2 server. After sending each message, wait for the server's response to avoid overloading it. Ensure the following sequence: + - Send the 10 "Unexpected Length" messages. + - Follow with the 10 "Corrupted Data" messages. + - Continue with the 5 "Unsupported Diffie-Hellman Groups" messages. + +- Conclude with the 5 "Empty KE Payload" messages. + +NOTE: Monitor the server's reactions closely. The server ideally handles errors gracefully, either ignoring them or responding with an appropriate error message, without any crashes or hangs. + +#### Expected Results + +- The IKEv2 server gracefully handles the malformed KE payloads, either by ignoring them, responding with an error, or requesting a valid KE payload. +- No crashes, hangs, or undefined behaviours occur. + +#### Expected format of evidence + +- Packet capture files (.pcap) highlighting the malformed KE payloads and the server's corresponding responses. +- Server logs detailing the handling (or rejection) of the malformed KE payloads. + +## 6.5.4 IKE Malformed Certificate Payload + +**Requirement Name:** Network Security Protocol - IPsec + +**Requirement Reference:** Clause 4.5, O-RAN Security Protocols Specifications [2] + +**Requirement Description:** Support IPsec tunnel mode with confidentiality, integrity, authentication, and anti-replay protection. + +**Threat References:** T-O-RAN-01 + +**DUT/s:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU + +**Test Name:** TC\_IKE\_MALFORMED\_CERTIFICATE\_PAYLOAD + +**Purpose:** This test aims to verify the IKEv2 server's capability to properly validate certificate payloads. Certificate payloads are essential in the IKEv2 authentication phase. A server vulnerable to malformed certificate payloads could be susceptible to impersonation or man-in-the-middle attacks. + +#### Procedure and execution steps + +##### Preconditions + +- A controlled environment with an IKEv2 server and a test client. +- Packet capture tool (e.g., Wireshark) to monitor and capture traffic. +- A set of both valid and deliberately malformed certificates. + +##### Execution steps + +#### 1. Valid Certificate Test: + +1. Initiate an IKEv2 session using a valid certificate to ensure baseline functionality. +2. Confirm successful authentication and session establishment. + +#### 2. Expired Certificate: + +1. Use a previously valid certificate that has now expired. +2. Attempt to initiate an IKEv2 session. +3. Observe the server's rejection of this certificate. + +**3. Certificate with Invalid Signature:** + +1. Modify a valid certificate's content slightly (e.g., change an attribute) without re-signing it. This will invalidate its signature. +2. Attempt to initiate an IKEv2 session using this certificate. +3. The server detects the invalid signature and rejects the connection. + +**4. Certificate from Untrusted Authority:** + +1. Generate a new certificate signed by a Certificate Authority (CA) that the IKEv2 server doesn't trust or recognize. +2. Attempt to initiate a connection using this certificate. +3. Observe the server rejecting the certificate due to the untrusted CA. + +**5. Certificate with Modified Subject/Issuer Fields:** + +1. Modify the subject or issuer fields of a certificate to contain irregular or unexpected values (e.g., overly long strings, special characters). +2. Use this certificate to initiate an IKEv2 session. +3. The server validates these fields, notices the irregularities, and potentially rejects the connection. + +**6. Certificate with Invalid Key Usage:** + +1. Use a certificate that doesn't have "key encipherment" or "digital signature" as its key usage, which are typically needed for IKEv2 operations. +2. Attempt to initiate a session. +3. The server detects the inappropriate key usage and declines the connection. + +**Expected Results:** + +- For the valid certificate, the IKEv2 server authenticates successfully and establish a session. +- For all other scenarios, the IKEv2 server detects the certificate anomalies and rejects the connection attempts. Specific error messages or logs relating to certificate validation failure are generated. + +**Expected format of evidence:** + +- Packet capture files (.pcap) capturing the entire exchange, showing the certificate exchange and the server's response. +- Server logs detailing the acceptance or rejection of each certificate, with corresponding reasons or error messages for rejections. + +## 6.6 OAuth 2.0 + +**Requirement Name:** Authorization based on OAuth 2.0 + +**Requirement Reference:** Clause 4.7, O-RAN Security Protocols Specifications [2] + +**Requirement Description:** O-RAN OAuth 2.0 based authorization including resource registration, access token request and service access request based on token verification process as defined in [2] + +**Threat References:** T-O-RAN-05 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_OAuth2.0\_Protocol + +**Purpose:** To verify implementation of the authorization for API consumer requests received by API producer based on OAuth 2.0 as specified in [2] + +### Procedure and execution steps + +#### Preconditions + +- Supported version of OAuth 2.0 +- Access token request process + - Mutual TLS authentication is required +- Service access request based on token verification process as defined in [2] + - Mutual TLS authentication is required +- API consumer – O-RAN architecture element as referred in DUT +- Resource owner/server – Service Producer as DUT +- Authorization server – OAuth 2.0 Authorization Server (real or emulated) + - API consumer registration can be a manual process with client profile pre-provisioned on the Authorization server based on client certificate's subject alternative name field + - Resource owner/server registered with the Authorization server for its supported API service(s) + - This process can be a manual or automatic process preceding with Resource owner/server authentication + - The API service profile(s) follows the definition in O-RAN specifications +- TLS service enabled on the Authorization Server, Resource owner/server and API consumer with all the required keys, root and/or immediate (if necessary) CA certificates required for mutual TLS authentication procedure +- Network access to Authorization Server, Resource owner/server and API consumer + +#### Execution steps + +Access token request process validation + +1. Access token request process with valid client certificate and parameters + +API consumer makes the access token request towards Authorization server over secured TLS communication session with mutual TLS authentication; + +![Sequence diagram showing the Access Token Request process between an OAuth 2.0 Client and an OAuth 2.0 Authorization Server.](c51aa95f241be1e009b036a321c5f3e2_img.jpg) + +``` + +sequenceDiagram + participant Client as OAuth 2.0 Client + participant Server as OAuth 2.0 Authorization Server + Note over Server: 2. Check whether the client (API service consumer) is authorized. If client is authorized, generate an access token. + Client->>Server: 1. AccessToken_Get Request +(Expected service name(s) and producer type, client type, client id, ...) + Server-->>Client: 3. AccessToken_Get Response +(expiration time, access_token) + +``` + +The diagram illustrates the sequence of operations for an access token request. It involves two main entities: the OAuth 2.0 Client and the OAuth 2.0 Authorization Server. The process begins with the client sending a request to the server. The server then performs an internal check to verify the client's authorization and generate an access token if valid. Finally, the server returns the response to the client. + +Sequence diagram showing the Access Token Request process between an OAuth 2.0 Client and an OAuth 2.0 Authorization Server. + +**Figure 6-1: Access Token request** + +Verify the session is established between the API consumer and Authorization server, and the access token request is processed with a successful response with digitally signed JSON Web Signature (JWS) as described in RFC 7515 [20] by the Authorization server. + +2. Access token request process with wrong client certificate + +API consumer sends the access token request towards Authorization server over secured TLS communication session with mutual TLS authentication; + +Verify the session establishment in between the API consumer and Authorization server is not possible. + +3. Access token request process with incorrect parameters + +API consumer sends the access token request with incorrect parameters towards Authorization server over secured TLS communication session with mutual TLS authentication; + +Verify the session is established between the API consumer and Authorization server, and the access token request is processed with a failed response by the Authorization server with error code defined in RFC 6749 [18]. + +Service access request based on token verification process as defined in [2] + +1. Service access request based on token verification process with valid access token + +API consumer sends an API service request towards Resource owner/server (API producer) using the access token obtained as a response to access token request over a secured TLS communication session with mutual TLS authentication; + +![Sequence diagram for Figure 6-2: Service request. It shows an OAuth 2.0 Client sending a service request (access token) to an OAuth 2.0 Resource Owner/Server. The Resource Owner/Server then verifies the integrity and claims in the access token. If successful, it executes the requested service and sends a service response back to the client.](5cbeda3247f593f05710c0f6cf112650_img.jpg) + +``` + +sequenceDiagram + participant Client as OAuth 2.0 Client + participant Server as OAuth 2.0 Resource Owner/Server + Client->>Server: 1. Service request (access token) + Note over Server: 2. Verify integrity and claims in the access token. If successful, execute the requested service + Server-->>Client: 3. Service response + +``` + +Sequence diagram for Figure 6-2: Service request. It shows an OAuth 2.0 Client sending a service request (access token) to an OAuth 2.0 Resource Owner/Server. The Resource Owner/Server then verifies the integrity and claims in the access token. If successful, it executes the requested service and sends a service response back to the client. + +**Figure 6-2: Service request** + +Verify the session is established between the API consumer and Resource owner/server (API producer), and the service request is processed with a response by the Resource owner/server (API producer). + +2. Service access request based on token verification process with incorrect access token + +API consumer sends an API service request towards Resource owner/server (API producer) using an incorrect access token over a secured TLS communication session with mutual TLS authentication; + +Verify the session is established between the API consumer and Resource owner/server (API producer), and the service request is processed with a failed response (401) by the Resource owner/server (API producer). + +**Expected results** + +The API consumers are able to execute API service(s) call with OAuth 2.0 based authorization. + +**Expected format of evidence:** Log files, traffic captures and/or screenshots. + +## 6.7 NACM + +### 6.7.1 NACM RBAC Configuration + +**Requirement Name:** NACM security + +**Requirement Reference:** REQ-NAC-FUN-1 to REQ-NAC-FUN-10, clause 5.2.2.1.3 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Netconf/NACM support + +**Threat References:** T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU + +**Test Name:** TC\_NACM\_RBAC\_CONFIGURATION + +**Purpose:** The purpose of this test is to verify the RBAC configuration for secure access control on the TLS-based NACM with NETCONF. + +#### Procedure and execution steps + +##### Preconditions + +- The NACM and NETCONF services are properly configured and operational. +- The RBAC feature is supported and enabled in the NACM system. +- RBAC roles, access control rules, and denied resources or operations are properly defined. + +##### Execution steps + +1. Verify RBAC role definitions. + - Check that RBAC roles are properly defined for access control. + - a) Review the RBAC role definitions. + - EXAMPLE: Command "**show nacm rbac roles**" + - b) Validate that the defined roles match the intended access control requirements. +2. Verify RBAC role assignment. + - Test the assignment of RBAC roles to users or user groups. + - a) Assign roles to users or user groups. + - EXAMPLE: "Command: **configure nacm rbac role-assignment**" + - b) Verify that the assigned roles are reflected in the configuration. +3. Verify unauthorized access denial. + - Test access to resources or operations that are not permitted for a specific RBAC role. + - a) Identify a resource or operation that is denied for a specific role. + - EXAMPLE: "Command **show nacm rbac role-permissions **" + - b) Attempt to access the denied resource or operation with a user assigned to the role. + +- EXAMPLE: "Command: **execute netconf operation** " + +### Expected Results + +1. For step 1), Roles are defined with their associated permissions and restrictions. +2. For step 2), Roles are assigned to the appropriate users or user groups. +3. For step 3)-a, The denied resource or operation is listed for the specified role. +4. For step 3)-b, Access to the denied resource or operation is denied, and an appropriate error message is displayed. + +### Expected format of evidence + +1. For step 1), The output of the **show nacm rbac roles** command, showing the defined roles and their associated permissions and restrictions. +2. For step 2), Confirmation that the roles have been successfully assigned to the appropriate users or user groups, as reflected in the configuration. +3. For step 3), An appropriate error message indicating access denial when attempting to access a denied resource or operation with a user assigned to a specific role. + +## 6.7.2 NACM Logging Monitoring + +**Requirement Name:** NACM security + +**Requirement Reference:** REQ-NAC-FUN-1 to REQ-NAC-FUN-10, clause 5.2.2.1.3 in O-RAN Security Requirements and Controls Specifications [5], REQ-SEC-SLM-AAI-EVT-1 to REQ-SEC-SLM-AAI-EVT-10, clause 5.3.8.11.6 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Netconf/NACM support + +**Threat References:** T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU + +**Test Name:** TC\_NACM\_LOGGING\_MONITORING + +**Purpose:** The purpose of this test is to verify the logging and monitoring configuration for the TLS-based NACM with NETCONF. + +### Procedure and execution steps + +#### Preconditions + +- The NACM and NETCONF services are properly configured and operational. +- Logging and monitoring systems are in place, integrated and configured with the NACM system. + +#### Execution steps + +1. Verify logging configuration. + - Check that logging is properly configured to capture relevant security-related events. + - a) Review the logging configuration settings. + - EXAMPLE: "Command: **show nacm logging configuration**" + - b) Trigger security-related events (e.g., access violations, failed authentication attempts) and validate that the events are logged. + +## 2. Verify monitoring configuration. + +- Test the monitoring configuration to ensure that security-related events and performance metrics are monitored. + - a) Review the monitoring configuration settings. + - EXAMPLE: "Command: **show nacm monitoring configuration**" + - b) Trigger security-related events or exceed performance thresholds and verify that the monitoring system captures and reports these events or metrics. + +## 3. Verify audit log review. + +- Test the ability to review audit logs for security-related events. + - a) Retrieve the audit logs. + - EXAMPLE: "Command: **show nacm audit-logs**" + - b) Review the audit logs to ensure that they contain the expected information and provide a detailed record of security-related activities. + +### Expected Results + +1. For step 1), Logging is enabled with appropriate log levels, log destinations, and log retention policies. +2. For step 2), Monitoring is enabled with appropriate metrics, thresholds, and alerting mechanisms. +3. For step 3), Audit logs containing security-related events are available. + +### Expected format of evidence + +1. Confirmation that logging is enabled with the expected log levels, log destinations, and log retention policies. Additionally, evidence of captured security-related events in the logs. +2. Confirmation that monitoring is enabled with the configured metrics, thresholds, and alerting mechanisms. Evidence of captured security-related events or performance metrics exceeding thresholds. +3. The audit logs containing security-related events, demonstrating that they contain the expected information and provide a detailed record of security-related activities. + +## 6.7.3 Void + +## 6.8 802.1X + +Void + +## 6.9 X.509 + +### 6.9.1 X.509 Certificate Structure Verification for TLS + +**Requirement Name:** X.509 security + +**Requirement Reference:** SEC-CTL-O1-1, clause 5.2.2. 2, SEC-CTL-O2, clause 5.2.3.1, REQ-SEC-OCLOUD-O2dms-1 to REQ-SEC-OCLOUD-O2dms-3, clause 5.1.8.9.1.1, REQ-SEC-OCLOUD-O2ims-1 to REQ-SEC-OCLOUD-O2ims-3, clause 5.1.8.9.1.2, REQ-SEC-O-CLOUD-NotifAPI-1 to REQ-SEC-O-CLOUD-NotifAPI-2, clause + +5.1.8.9.1.3, SEC-CTL-A1-1, SEC-CTL-A1, clause 5.2.1.1 [5], SEC-CTL-R1-1, SEC-CTL-R1, clause 5.2.6.1, REQ-SEC-Y1-1 to REQ-SEC-Y1-3, clause 5.2.7.2, O-RAN Security Requirements and Controls Specifications [5], clause 4.2.3 in O-RAN Security Protocols Specifications [2]. + +**Requirement Description:** To verify the X.509 certificate structure used by TLS components in all the ORAN systems. + +**Threat References:** T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_X509\_CERT\_STRUCTURE\_VERIFICATION + +**Purpose:** The purpose of this test is to ensure that the X.509 certificate follows the correct structure and format for TLS. This test is applicable to X.509 certificates used in TLS modules in the O-RAN system. + +### Procedure and execution steps + +#### Preconditions: + +- End entity X.509 certificate in ASN.1 format. +- CA certificate that signed the end entity certificate is available to the test suite. + +#### Execution steps + +Following properties of the certificate are verified. + +- Certificate Version field, Subject field, Issuer, Validity of certificate, Key Usage. + +As defined in clause 4.2.3 in O-RAN Security Protocols Specifications [2], the following certificate fields are present. + +#### 1. Certificate Fields Examination: + +- Validate the certificate's version field. The version number is set to v3. +- Verify the Subject field is present in the certificate. Verify that the Subject field conforms to the format defined in clause 4.2.3 in O-RAN Security Protocols Specifications [2]. +- Verify the Validity field to ensure the "Not Before" date is earlier than the "Not After" date, indicating a valid time range for the certificate's use. +- Validate that the certificate's signature field is based on the algorithm used by the CA to sign the certificate. + +#### 2. Key Usage Extension: + +- Validate the presence of the Key Usage Extension. Verify that it conforms with the mandatory critical Key Usage extension as specified in the clause 4.2.3 in O-RAN Security Protocols Specifications [2]. + +#### 3. CRL Distribution Point: + +- Validate that the certificate contains the cRLDistributionPoint extension. + +#### 4. Subject Alternative Name: + +- Validate that the certificate contains the subjectAltName extension and conforms to the requirements as specified in the clause 4.2.3 in O-RAN Security Protocols Specifications [2]. + +### Expected Results + +The certificate adheres to the X.509 standard structure as defined in clause 4.2.3 in O-RAN Security Protocols Specifications [2]. + +### Expected format of evidence + +Log or report indicating successful certificate structure validation. + +## 6.9.2 X.509 Certificate Validity Period Verification + +**Requirement Name:** X.509 security + +**Requirement Reference:** SEC-CTL-O1-1, clause 5.2.2.1.2, REQ-SEC-O2-1, clause 5.2.3.1, REQ-SEC-OCLOUD-O2dms-1 to REQ-SEC-OCLOUD-O2dms-3, clause 5.1.8.9.1.1, REQ-SEC-OCLOUD-O2ims-1 to REQ-SEC-OCLOUD-O2ims-3, clause 5.1.8.9.1.2, REQ-SEC-O-CLOUD-NotifAPI-1 to REQ-SEC-O-CLOUD-NotifAPI-2, clause 5.1.8.9.1.3, REQ-SEC-A1-1, REQ-SEC-A1-2, clause 5.2.1.1, REQ-SEC-E2-1, clause 5.2.4.1, REQ-SEC-R1-1, REQ-SEC-R1-2, clause 5.2.6.1, REQ-SEC-Y1-1 to REQ-SEC-Y1-3, clause 5.2.7.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Correctness of X.509 certificate + +**Threat References:** T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_X509\_CERT\_VALIDITY\_PERIOD\_VERIFICATION + +**Purpose:** The purpose of this test is to ensure that the certificate's validity dates are accurate and within an acceptable range. This test is relevant for all X.509 certificates within the O-RAN system. + +### Procedure and execution steps + +#### Preconditions + +- Prepare certificates with different validity periods (valid, expired, not yet valid). + +#### Execution steps + +##### 1. Verify a Valid Certificate: + +- Set up a valid certificate with appropriate "Not Before" and "Not After" dates. +- Verify that the certificate is accepted when used for its intended purpose. + +##### 2. Verify an Expired Certificate: + +- Set up a certificate with a past expiration date. +- Attempt to use the expired certificate for its intended purpose. +- Verify that the certificate is rejected due to expiration. + +##### 3. Verify a Not Yet Valid Certificate: + +- Set up a certificate with a "Not Before" date in the future. +- Attempt to use the certificate before the valid start date. +- Verify that the certificate is rejected due to being not yet valid. + +#### Expected Results + +Valid certificates are accepted, while expired and not-yet-valid certificates are rejected. + +#### Expected format of evidence + +Log or report showing successful validation and rejection for different validity periods. + +## 6.9.3 X.509 Certificate Key Usage Verification + +**Requirement Name:** X.509 security + +**Requirement Reference:** SEC-CTL-O1-1, clause 5.2.2.1.2, REQ-SEC-O2-1, clause 5.2.3.1, REQ-SEC-OCLOUD-O2dms-1 to REQ-SEC-OCLOUD-O2dms-3, clause 5.1.8.9.1.1, REQ-SEC-OCLOUD-O2ims-1 to REQ-SEC-OCLOUD-O2ims-3, clause 5.1.8.9.1.2, REQ-SEC-O-CLOUD-NotifAPI-1 to REQ-SEC-O-CLOUD-NotifAPI-2, clause 5.1.8.9.1.3, REQ-SEC-A1-1, REQ-SEC-A1-2, clause 5.2.1.1, REQ-SEC-E2-1, clause 5.2.4.1, REQ-SEC-R1-1, REQ-SEC-R1-2, clause 5.2.6.1, REQ-SEC-Y1-1 to REQ-SEC-Y1-3, clause 5.2.7.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Correctness of X.509 certificate + +**Threat References:** T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_X509\_CERT\_KEY\_USAGE\_VERIFICATION + +**Purpose:** The purpose of this test is to confirm that the certificate's key usage and extended key usage extensions are correctly defined. + +### Procedure and execution steps + +#### Preconditions + +- Prepare certificates with different key usage and extended key usage extensions. + +#### Execution steps + +##### 1. Verify a Certificate with Correct Usage Extensions: + +- Set up a certificate with proper key usage and extended key usage extensions matching its intended purpose (e.g., server authentication). +- Attempt to use the certificate for its designated purpose. +- Verify that the certificate is accepted. + +##### 2. Verify a Certificate with Incorrect or Missing Usage Extensions: + +- Set up a certificate with incorrect or missing key usage or extended key usage extensions. +- Attempt to use the certificate for its intended purpose. +- Verify that the certificate is rejected. + +#### Expected Results + +Certificates with correct usage extensions are accepted, while those with incorrect or missing extensions are rejected. + +#### Expected format of evidence + +Log or report indicating successful validation and rejection for different key usage scenarios. + +## 6.9.4 X.509 Certificate Chain Validation + +**Requirement Name:** X.509 security + +**Requirement Reference:** SEC-CTL-O1-1, clause 5.2.2.1.2, REQ-SEC-O2-1, clause 5.2.3.1, REQ-SEC-OCLOUD-O2dms-1 to REQ-SEC-OCLOUD-O2dms-3, clause 5.1.8.9.1.1, REQ-SEC-OCLOUD-O2ims-1 to REQ-SEC- + +O-CLOUD-O2ims-3, clause 5.1.8.9.1.2, REQ-SEC-O-CLOUD-NotifAPI-1 to REQ-SEC-O-CLOUD-NotifAPI-2, clause 5.1.8.9.1.3, REQ-SEC-A1-1, REQ-SEC-A1-2, clause 5.2.1.1, REQ-SEC-E2-1, clause 5.2.4.1, REQ-SEC-R1-1, REQ-SEC-R1-2, clause 5.2.6.1, REQ-SEC-Y1-1 to REQ-SEC-Y1-3, clause 5.2.7.2 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Correctness of X.509 certificate chain + +**Threat References:** T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_X509\_CERT\_CHAIN\_VALIDATION + +**Purpose:** The purpose of this test is to validate the certificate chain's integrity and trustworthiness. This test is applicable to scenarios where certificates are part of a chain (e.g., intermediate and root certificates). + +### Procedure and execution steps + +#### Preconditions + +- Prepare a certificate chain with correct and incorrect configurations. + +#### Execution steps + +##### 1. Verify a Certificate Chain with Correct Order and Valid Signatures: + +- Set up a valid certificate chain with proper order and valid signatures. +- Attempt to use the certificate chain for its intended purpose. +- Verify that the certificate chain is accepted. + +##### 2. Verify a Certificate Chain with Incorrect Order or Invalid Signatures: + +- Set up a certificate chain with incorrect order or invalid signatures. +- Attempt to use the certificate chain for its intended purpose. +- Verify that the certificate chain is rejected. + +#### Expected Results + +A valid certificate chain is accepted, while an invalid chain is rejected. + +#### Expected format of evidence + +Log or report indicating successful validation and rejection for different certificate chain scenarios. + +## 6.10 eCPRI + +### 6.10.1 Void + +### 6.10.2 eCPRI Input Validation + +**Requirement Name:** eCPRI security + +**Requirement Reference:** REQ-SEC-TRAN-1, clause 5.3.4.1 in O-RAN Security Requirements and Controls Specifications [5]. + +**Requirement Description:** eCPRI protocol robustness – ability to handle unexpected inputs (not in-line with protocol specification) without functional compromise. + +**Threat References:** T-FRHAUL-01, T-FRHAUL-02 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_eCPRI\_INPUT\_VALIDATION + +**Purpose:** The purpose of this test is to ensure that the DUT properly validates and sanitizes input through the eCPRI interface to prevent common security vulnerabilities such as injection attacks. + +### Procedure and execution steps + +#### Preconditions + +- eCPRI interface is accessible. +- Input fields requiring validation are identified. + +#### Execution steps + +1. Positive Case: + - a) Send requests through the eCPRI interface with valid and expected input values. + - b) Verify that the DUT processes the requests successfully and provides the expected responses. +2. Negative Case: + - a) Generate requests through the eCPRI interface by systematically applying fuzzing techniques to introduce deliberately malicious input values containing potential security threats. + - b) Verify that the DUT detects and rejects the malicious input, responding with appropriate error messages or status codes. + +**Expected Results:** The DUT validates and sanitizes input through the eCPRI interface to prevent security vulnerabilities related to improper input handling. + +#### Expected format of evidence + +- A log file documenting the requests sent to the DUT through the eCPRI interface, including valid and malicious inputs. +- Screenshots of the DUT responses through the eCPRI interface showing the handling of valid inputs and appropriate error messages for malicious inputs. + +## 6.10.3 eCPRI Error and Timeout Handling + +**Requirement Name:** eCPRI security + +**Requirement Reference:** REQ-SEC-TRAN-1, clause 5.3.4.1 in O-RAN Security Requirements and Controls Specifications [5]. + +**Requirement Description:** eCPRI protocol robustness - ability to handle unexpected inputs (not in-line with protocol specification) without functional compromise. + +**Threat References:** T-FRHAUL-01, T-FRHAUL-02 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_eCPRI\_ERROR\_TIMEOUT\_HANDLING + +**Purpose:** The purpose of this test is to ensure that the DUT securely handles errors on the eCPRI interface, including malformed packets, unexpected messages, and timeout scenarios, without disclosing sensitive information or compromising DUT stability. + +#### Procedure and execution steps + +##### Preconditions + +- eCPRI interface is accessible. +- Various error scenarios (malformed, unexpected, or delayed eCPRI packets) are identified. + +##### Execution steps + +1. Attempt to force error conditions on the eCPRI interface: + - Transmit eCPRI packets with anomalies such as invalid headers, incorrect protocol versions, unsupported message types, or corrupted payloads. + - Introduce significant delays or slow down the network connection on the eCPRI interface. +2. Verify that the DUT detects and handles the errors appropriately, responding with informative error messages without revealing sensitive information. +3. Validate that the error messages provide helpful and actionable information for troubleshooting. +4. Restore normal connectivity. +5. Resend a normal request to the DUT through the eCPRI interface. +6. Verify that the DUT processes the request successfully and provides the expected response. + +**Expected Results:** The DUT handles errors securely, providing meaningful error messages without disclosing sensitive information and recovering seamlessly when the connection is restored. + +##### Expected format of evidence + +- Screenshots of the error messages or status codes received from the DUT through the eCPRI interface in response to triggered errors. +- A log file documenting the requests and responses during error scenarios. + +## 6.10.4 Void + +## 6.10.5 eCPRI Logging and Auditing + +**Requirement Name:** eCPRI security + +**Requirement Reference:** REQ-SEC-SLM-APP-EVT-1, clause 5.3.8.8.11.4 in O-RAN Security Requirements and Controls Specifications [5]. + +**Requirement Description:** + +**Threat References:** T-FRHAUL-01, T-FRHAUL-02 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_eCPRI\_LOGGING\_AUDITING + +**Purpose:** The purpose of this test is to validate that the DUT logs relevant security events and activities on the eCPRI interface and supports auditing capabilities. + +#### Procedure and execution steps + +### Preconditions + +- eCPRI interface is accessible. +- Logging and auditing mechanisms are enabled and configured. + +### Execution steps + +1. Perform various eCPRI security events. Key eCPRI security events include [26]: + - Total count of received messages (valid and erroneous) for user and control planes + - Messages received within the expected time window + - Early and late arrivals of messages + - Sequence ID errors for on-time messages + - Messages dropped due to protocol violations or corruption + - Timing and sequence errors in control plane messages + - Total outbound messages for user and control planes + - Messages discarded due to errors, resource constraints, or policy violations + - Identified duplicated packets. +2. Verify that the DUT generates appropriate log entries for each security event, capturing relevant security-related information. +3. Access and review the generated logs to ensure they contain the necessary details for security auditing purposes. + +**Expected Results:** The DUT generates accurate logs, recording security-related events and activities for auditing and forensic analysis. + +### Expected format of evidence + +- The generated log files containing recorded security events and activities during the testing process. +- Screenshots of log entries highlighting relevant security events and timestamps. + +## 6.10.6 Void + +## 6.11 SCTP + +### 6.11.1 Void + +### 6.11.2 Void + +### 6.11.3 Void + +### 6.11.4 Void + +### 6.11.5 SCTP DoS Prevention Rate Limiting + +**Requirement Name:** SCTP security + +**Requirement Reference:** REQ-SEC-TRAN-1, clause 5.3.4.1 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Ability to handle unexpected input + +**Threat References:** T-E2-01, T-E2-02, T-E2-03 + +**DUT/s:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU + +**Test Name:** TC\_SCTP\_DOS\_PREVENTION\_RATE\_LIMITING + +**Purpose:** The purpose of this test is to verify that the SCTP protocol effectively handles DoS attacks and prevents resource exhaustion. + +### Procedure and execution steps + +#### Preconditions + +- Enable DoS prevention mechanisms. +- The rate limiting parameters, such as the maximum number of connections or allowed data transfer rate, are properly defined. +- Use SCTP library. +EXAMPLE: the sctplib library in the C programming language + +#### Execution steps + +1. Simulate a DoS attack by overwhelming the SCTP protocol with a large number of connection requests (send data at a rate that exceeds the defined rate limiting parameters). + - EXAMPLE: Sample SCTP commands: + - ``` +for (int i = 0; i < num_connections; i++) {sctp_socket = sctp_socket(AF_INET, SOCK_STREAM, IPPROTO_SCTP); +// Establish connections rapidly beyond system limits +} +``` +2. Monitor the SCTP protocol's response and behaviour during the excessive connection and data transfer attempts. + +#### Expected Results + +- The SCTP protocol detects the excessive usage and applies rate limiting measures to restrict or reject connections or data transfers that exceed the defined limits. +- The system handles the rate limiting effectively, ensuring that resources are not exhausted or overwhelmed. + +#### Expected format of evidence + +- Test logs showing successful handling of the DoS attack, such as connection limits or rejection messages. +- System performance metrics or logs indicating the proper handling of excessive connection requests. + +## 6.11.6 SCTP Input Validation + +**Requirement Name:** SCTP security + +**Requirement Reference:** REQ-SEC-TRAN-1, clause 5.3.4.1 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Ability to handle unexpected input + +**Threat References:** T-E2-01, T-E2-02, T-E2-03 + +**DUT/s:** Near-RT RIC, O-CU-CP, O-CU-UP, O-DU + +**Test Name:** TC\_SCTP\_INPUT\_VALIDATION + +**Purpose:** To verify that the SCTP protocol performs proper input validation to prevent security vulnerabilities such as buffer overflows or injection attacks. + +#### Procedure and execution steps + +##### Preconditions + +- The SCTP protocol is configured with input validation enabled. +- Use SCTP library. + +EXAMPLE: the sctplib library in the C programming language + +##### Execution steps + +1. Attempt to establish a connection using the SCTP protocol and provide invalid or malicious input. + - EXAMPLE: Sample SCTP command: `sctp_socket = sctp_socket(AF_INET, SOCK_STREAM, IPPROTO_SCTP);` +2. Send data containing invalid or malicious content over the connection. + - EXAMPLE: Sample SCTP command: `sctp_sendmsg(sctp_socket, malicious_data_buffer, data_length, NULL, 0, 0, 0, stream_id, 0, 0);` + +##### Expected Results + +- The SCTP protocol performs input validation and rejects or sanitizes the invalid or malicious input. +- The connection is not established, or the malicious data is handled safely. + +##### Expected format of evidence + +- Test logs showing the rejection or sanitization of invalid or malicious input. +- Output from the application indicating the successful validation and rejection of malicious data. + +## 6.11.7 Void + +## 6.11.8 Void + +# 6.12 Transactional APIs + +## 6.12.1 Transactional API Authentication + +**Requirement Name:** RESTful API protection + +**Requirement Reference:** ‘REQ-SEC-O-CLOUD-NotifAPI-1, REQ-SEC-O-CLOUD-NotifAPI-2’ clause 5.1.8.9.1.3 [5], ‘REQ-SEC-API-1, REQ-SEC-API-2, REQ-SEC-API-3, REQ-SEC-API-4, REQ-SEC-API-5, REQ-SEC-API-6, REQ-SEC-API-8, REQ-SEC-API-9, REQ-SEC-API-10, REQ-SEC-API-13, REQ-SEC-API-15’ clause 5.3.10.2 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** API robustness + +**Threat References:** T-O-RAN-01, T-O-RAN-02, T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_REST\_API\_AUTHENTICATION + +**Purpose:** The purpose of this test is to verify the authentication mechanism of an O-RAN NF supporting RESTful API. + +## Procedure and execution steps + +### Preconditions + +- An O-RAN NF supporting the RESTful API is provisioned and running. +- Access to the O-RAN NF management system or command-line interface. + +### Execution steps + +#### 1. Positive Case: + +- a) Authenticate using valid credentials or API tokens: + +**EXAMPLE:** `curl -X POST -H "Content-Type: application/json" -d '{"username":"","password":""}' http:///auth` + +- b) Capture the authentication token from the response. +- c) Execute an authenticated request against an O-RAN NF resource (e.g., get cell status). +- d) Verify that the request is successful and returns the expected response. + +#### 2. Negative Case: + +Attempt to access the O-RAN RESTful API without providing valid authentication credentials: + +`curl http:///cell-status` + +- a) Verify that the request fails and returns an unauthorized response. + +### Expected Results + +#### 1. Positive Case: + +- Authentication using valid credentials or API tokens is successful. +- Authorized requests to O-RAN NF resources return the expected responses. + +#### 2. Negative Case: + +- Requests without valid authentication credentials are rejected with an unauthorized response. + +### Expected format of evidence + +- Screenshots or logs showing the successful authentication and authorized requests. +- Screenshots or logs showing the failed authentication attempts. + +## 6.12.2 Transactional API Authorization and Access Control + +**Requirement Name:** RESTful API protection + +**Requirement Reference:** ‘REQ-SEC-O-CLOUD-NotifAPI-1, REQ-SEC-O-CLOUD-NotifAPI-2’ clause 5.1.8.9.1.3 [5], ‘REQ-SEC-API-1, REQ-SEC-API-2, REQ-SEC-API-3, REQ-SEC-API-4, REQ-SEC-API-5, REQ-SEC-API-6, REQ-SEC-API-8, REQ-SEC-API-9, REQ-SEC-API-10, REQ-SEC-API-13, REQ-SEC-API-15’ clause 5.3.10.2 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** API robustness + +**Threat References:** T-O-RAN-01, T-O-RAN-02, T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_REST\_AUTHORIZATION\_ACCESS\_CONTROL + +**Purpose:** The purpose of this test is to ensure that the RESTful API enforces proper authorization and access control mechanisms. + +### Procedure and execution steps + +#### Preconditions + +- An O-RAN NF supporting the RESTful API is provisioned and running. +- Access to the O-RAN NF management system or command-line interface. +- User roles and permissions are defined and configured. + +#### Execution steps + +1. Positive Case: + +- a) Authenticate using credentials associated with a user assigned to a role with necessary permissions: + +EXAMPLE: `curl -X POST -H "Content-Type: application/json" -d '{"username":"","password":""}' http:///auth` + +- b) Capture the authentication token from the response. +- c) Execute a request that requires the permissions granted by the user's role (e.g., update configuration). +- d) Verify that the request is successful and returns the expected response. + +2. Negative Case: + +- a) Authenticate using credentials associated with a user not assigned to a role with necessary permissions: + +EXAMPLE: `curl -X POST -H "Content-Type: application/json" -d '{"username":"","password":""}' http:///auth` + +- b) Capture the authentication token from the response. +- c) Execute a request that requires the permissions beyond the user's role (e.g., perform a restricted operation). +- d) Verify that the request fails and returns a forbidden response. + +#### Expected Results + +1. Positive Case: + +- Users with appropriate roles and permissions can perform authorized actions. +- Requests requiring specific permissions return the expected responses. + +2. Negative Case: + +- Users without necessary roles or permissions are restricted from performing unauthorized actions. +- Requests requiring permissions beyond the user's role return a forbidden response. + +#### Expected format of evidence + +- Screenshots or logs showing the successful authorization and access control enforcement. +- Screenshots or logs showing the failed authorization attempts. + +## 6.12.3 Transactional API Input Validation and Sanitization + +**Requirement Name:** RESTful API protection + +**Requirement Reference:** ‘REQ-SEC-O-CLOUD-NotifAPI-1, REQ-SEC-O-CLOUD-NotifAPI-2’ clause 5.1.8.9.1.3 [5], ‘REQ-SEC-API-1, REQ-SEC-API-2, REQ-SEC-API-3, REQ-SEC-API-4, REQ-SEC-API-5, REQ-SEC-API-6, REQ-SEC-API-8, REQ-SEC-API-9, REQ-SEC-API-10, REQ-SEC-API-13, REQ-SEC-API-15’ clause 5.3.10.2 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** API robustness + +**Threat References:** T-O-RAN-01, T-O-RAN-02, T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_REST\_INPUT\_VALIDATION\_SANITIZATION + +**Purpose:** The purpose of this test is to validate that the RESTful API properly validates and sanitizes input data to prevent common security vulnerabilities. + +### Procedure and execution steps + +#### Preconditions + +- An O-RAN NF supporting the RESTful API is provisioned and running. +- Access to the O-RAN NF management system or command-line interface. + +#### Execution steps + +##### 1. Positive Case: + +- a. Construct a valid request with appropriate input data: + +EXAMPLE: `curl -X POST -H "Content-Type: application/json" -d '{"parameter1":"value1", "parameter2":"value2"}' http:///api-endpoint` + +- b. Verify that the request is successful and returns the expected response. + +##### 2. Negative Case: + +- a. Construct a request with invalid or malicious input data: + +EXAMPLE: `curl -X POST -H "Content-Type: application/json" -d '{"parameter1":"", "parameter2":"value2"}' http:///api-endpoint` + +- b. Verify that the request fails and returns an error response or rejects the malicious input. + +#### Expected Results + +##### 1. Positive Case: + +- a. Requests with valid and appropriate input data are successfully processed. +- b. Responses from the O-RAN NF RESTful API are as expected. + +##### 2. Negative Case: + +- a. Requests with invalid or malicious input data are rejected or handled properly to prevent security vulnerabilities. + +#### Expected format of evidence + +- Screenshots or logs showing the successful input validation and sanitization. +- Screenshots or logs showing failed input validation or sanitization attempts. + +## 6.12.4 Transactional API Security Logging and Monitoring + +**Requirement Name:** RESTful API protection + +**Requirement Reference:** ‘REQ-SEC-O-CLOUD-NotifAPI-1, REQ-SEC-O-CLOUD-NotifAPI-2’ clause 5.1.8.9.1.3 [5], ‘REQ-SEC-API-1, REQ-SEC-API-2, REQ-SEC-API-3, REQ-SEC-API-4, REQ-SEC-API-5, REQ-SEC-API-6, REQ-SEC-API-8, REQ-SEC-API-9, REQ-SEC-API-10, REQ-SEC-API-13, REQ-SEC-API-15’ clause 5.3.10.2 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** API robustness + +**Threat References:** T-O-RAN-01, T-O-RAN-02, T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_REST\_SECURITY\_LOGGING\_MONITORING + +**Purpose:** The purpose of this test is to verify that the O-RAN NF logs and monitors API activities for security and compliance purposes. + +### Procedure and execution steps + +#### Preconditions + +- An O-RAN NF supporting the RESTful API is provisioned and running. +- Access to the O-RAN NF management system or command-line interface. + +#### Execution steps + +1. Positive Case: + - a) Enable API logging and monitoring for the O-RAN NF. + - b) Generate a series of API requests and actions. + - c) Review the logs or monitoring system for the recorded activities. +2. Negative Case: + - a) Attempt unauthorized API actions or exploit security vulnerabilities. + - b) Verify that the logs or monitoring system captures and raises alerts for these activities. + +### Expected Results + +1. Positive Case: + - API activities are logged and monitored by the O-RAN NF. + - Logs or monitoring system records the expected API requests and actions. +2. Negative Case: + - Unauthorized or malicious API actions trigger alerts in the logs or monitoring system. + - Logs or monitoring system captures and records failed security attempts. + +### Expected format of evidence + +Screenshots or logs from the O-RAN NF management system showing the successful or failed API logging and monitoring settings. + +--- + +## 7 Common Network Security Tests for O-RAN architecture elements + +### 7.1 Overview + +This clause contains a set of security evaluations that are performed from outside and inside of the network function in a network capacity. It is used to measure the external exposure and risk(s) of the function in place and leverages common techniques used in cyber security to evaluate the risk(s) device under test faces or has. + +The objects in scope of these network-based security tests are SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU and O-Cloud. + +### 7.2 Network Protocol and Service Enumeration + +#### 7.2.1 Network Protocol and Service Enumeration + +**Requirement Name:** Network protocol and service enumeration + +**Requirement Reference:** REQ-SEC-NET-1, clause 5.3.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Protocols and services are documented by vendor. No undocumented protocols and services are offered. + +**Threat References:** T-O-RAN-01, T-O-RAN-02 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test name:** TC\_Network\_Prococol\_And\_Enumeration + +**Purpose:** To verify that the list of active network protocols and services on DUT is in line with vendor-provided list of network protocols and services supported. Probing of network protocols and services on DUT provides the information whether the service is active or not. This test case probes all possible TCP and SCTP ports in range 0-65535 using port scanner for presence of the active services. + +This test case probes all documented UDP ports from vendor-provided list using port scanner for presence of the active services. Optionally, additional UDP ports may be scanned as well. + +NOTE 1: In practice, such probing is often referred to as network scanning or port scanning. + +NOTE 2: In practice, services may also run on ports different from ports defined in [i.1]. + +#### Procedure and execution steps + +##### Preconditions + +- Port scanner with capabilities as defined in clause 5.3 of present document. +- Network access to DUT +- Vendor-provided list of network protocols and services supported by DUT + +##### Execution steps + +1. List of open ports are determined as follows: + - Port scanner scans all TCP ports in range 0-65535 on the IP interface of DUT. TCP SYN/ACK response by DUT are interpreted as open port. + +- Port scanner scans all SCTP ports in range 0-65535 on the IP interface of DUT. SCTP INIT-ACK response by DUT are interpreted as open port. +- All UDP ports documented in vendor-provided list are interpreted as open ports. Other UDP ports may be considered as open for the purpose of service detection. + +NOTE 3: Due to the nature of UDP protocol, there is no simple method of open port detection similar to TCP/SCTP methods based on analysis of response message type (TCP: SYN/ACK, SCTP: INIT-ACK). In case of UDP, open port detection inevitably relies on service detection which is discussed in step 2 of this test procedure. In practice, port scans of entire UDP port range 0-65535 are impractical and time consuming. Typically, service detection is performed only for subset of UDP ports. UDP port subset selection is arbitrary and not standardized. Service detection in this test procedure is required for UDP ports from vendor-provided list and is optional for other UDP ports. + +- For each open port from previous step, port scanner performs service detection by sending service probe(s) as follows: + - If open port is listed in vendor-provided list, port scanner uses service probe from its built-in database that exactly matches service documented in vendor-provided list. + - If open port is not listed in vendor-provided list, port scanner uses service probe from its built-in database that exactly matches service defined in [i.1] for the that open port. If such service is not defined in [i.1], port scanner may report service as "unknown". Alternatively, port scanner may perform further service detection attempts based on other service probes from its built-in database. + +NOTE 4: Service detection for open ports that are also listed in vendor-provided list requires only one probe. However, service information can be helpful in discussion with DUT vendor. This test procedure therefore accommodates optional service detection based on one probe or multiple probes. + +- Port scanner produces list of detected active network protocols, ports and services on DUT. + +### Expected results + +Comparison between the vendor-provided list of all supported network protocols and services and the list of active network protocols and services found by port scanner is performed. + +All services found by port scanner are documented in vendor-provided list. This test case ends with success if: + +- both lists match exactly +- list of network protocols and services found by port scanner has fewer items than vendor-provided list; all items found by port scanner exactly match items from vendor-provided list. + +If any service is found by port scanner and it is not documented in vendor-provided list, this test case shall fail. It means that vendor-provided list is incorrect and undocumented attack surface exists. + +**Expected format of evidence:** Result of probing the DUT is a list of active network protocols and services. Each item contains network protocol (TCP, UDP, SCTP), port number (from range 0-65535) and service name. If service type cannot be determined during probing, service name is "unknown". + +Service name is in line with Service Name and Transport Protocol Port Number Registry defined by IANA [i.1] . If service name is not defined in [i.1], vendor provided service name is used. + +## 7.3 Password-Based Authentication + +### 7.3.1 Password guessing + +**Requirement Name:** Password-Based Authentication + +**Requirement Reference:** SEC-CTL-PASS-2, clause 5.5.7.2, REQ-SEC-PASS-1, clause 5.3.7.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Password guessing protection mechanism is present on the DUT + +**Threat References:** T-O-RAN-02, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_Password\_Guessing + +**Purpose:** To verify that DUT has protection mechanism(s) implemented to prevent password guessing attacks against services using password-based authentication. . Simulation of password guessing attacks against services on DUT provides the information whether any protection mechanism is present. + +This test case is run against all services on DUT that use password-based authentication. Vendor-provided list of all supported network protocols and services are used as a source. + +NOTE 1: Vendor-provided list of all supported network protocols and services may not include the specific information about presence of password-based authentication as it is including network protocol, port and service name. In practice, only subset of services from vendor-provided list will use password-based authentication. + +## Procedure and execution steps + +### Preconditions + +- Valid username for each tested service. This test case does not mandate any specific list of passwords to be used for testing. +- Network access to DUT +- Physical access to DUT (applicable if the DUT is in physical form) +- Vendor-provided list of network protocols and services supported by DUT +- Number of authentication attempts configured in account lock-out policy + +### Execution steps + +1. List of services using password-based authentication is determined by analyzing the vendor-provided list as well as by analyzing local services that are not remotely accessible. +2. For services identified in the previous step, presence of protection mechanism is tested as follows: + - combination of valid username and invalid password (or various invalid passwords) are used for authentication repeatedly. + - after certain number of authentication attempts, protection mechanism of DUT are detected. + - minimum number of authentication attempts is the calculated as (number configured in the lock-out policy + 1) attempts . + +### Expected results + +In context of each of the services using password-based authentication, protection mechanism(s) is present. Applicable to local services and to remotely accessible services. + +NOTE 2: In practice, brute-forcing and dictionary attacks are the most common classes of password guessing attacks. Traditional approach to brute-forcing and dictionary attacks uses fixed username with various candidate passwords. Password spraying is another approach that can be combined with brute-forcing and dictionary attacks; fixed password is tested with various candidate usernames. Example of protection mechanism is enforcing delay before next authentication attempt(s) by the same client. This test case cannot list all possible techniques that protection mechanisms can use. However, following list provides overview of the most common approaches: + +- Increase the delay after each unsuccessful authentication attempt. +- Implement challenge-response authentication (example of such measure: CAPTCHA) +- In order to prevent more attempts, impose temporary lock out on the client when threshold of consecutive failed authentication attempts is reached. During defined period of time all authentication attempts by locked-out client are rejected. + +EXAMPLE: Lock-out policy is configured for 10 invalid authentication attempts. If DUT uses protection mechanism based on delaying authentication attempts, such delay is observed when DUT receives 11th consecutive invalid authentication attempt. + +This test case fails if one or more services using password-based authentication have no protection mechanism present. + +**Expected format of evidence:** Report file, log files and/or screenshots. + +## 7.3.2 Unauthorized Password Reset + +**Requirement Name:** Password-Based Authentication + +**Requirement Reference:** REQ-SEC-PASS-1, clause 5.3.7.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Out-of-band password recovery mechanism absent or deactivated on DUT + +**Threat References:** T-O-RAN-02, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_Unauthorized\_Password\_Reset + +**Purpose:** To verify that password reset mechanism DUT cannot be circumvented, disabled, or misused to gain access to DUT, its configuration, and data. Test covers services using password-based authentication and out-of-band mechanisms of password reset present in DUT in physical form. + +### Procedure and execution steps + +#### Preconditions + +- Network access to DUT +- Physical access to DUT (applicable if the DUT is in physical form) +- Vendor-provided list of network protocols and services supported by DUT + +#### Execution steps + +List of services using password-based authentication are determined by analyzing the vendor-provided list as well as by analyzing local services that are not remotely accessible. + +1. For services identified in the previous step, presence of password reset is tested. +2. For DUT that has physical form, it verifies that use of hardware factory reset switch or switches results in factory reset. Using any out-of-band mechanism, it is not possible to reset password only. If password reset is required, factory reset of O-RAN component is performed. Factory reset wipes O-RAN component, its configuration and data. + +### Expected results + +In context of each of the services using password-based authentication, no password change mechanism is present. Applicable to local services and to remotely accessible services. + +This test case fails if one or more services using password-based authentication have password reset mechanism exposed. + +This test case fails if DUT in physical form has hardware switch or switches that can be used to reset password without triggering factory reset of DUT. + +**Expected format of evidence:** Report file, log files and/or screenshots. + +### 7.3.3 Password Policy Enforcement + +**Requirement Name:** Password-Based Authentication + +**Requirement Reference:** REQ-SEC-PASS-1, clause 5.3.7.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Secure password policy is supported and enforced on the DUT + +**Threat References:** T-O-RAN-02, T-O-RAN-03, T-O-RAN-05, T-O-RAN-06 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_Password\_Policy\_Enforcement + +**Purpose:** To verify that password policy applied for services using password-based authentication is effectively enforced by DUT. + +#### Procedure and execution steps + +##### Preconditions + +- Set of valid username and valid password for each tested service +- Network access to DUT +- Physical access to DUT (applicable if the DUT is in physical form) +- Vendor-provided list of network protocols and services supported by DUT +- Password policy that is actually applied on the DUT + +##### Execution steps + +1. List of services using password-based authentication is determined by analyzing the vendor-provided list as well as by analyzing local services that are not remotely accessible. +2. For services identified in the previous step, effectiveness of password policy enforcement is verified as follows: + - combination of valid username and valid password are used to authenticate + - password change is performed using password that does not conform to applied password policy + +EXAMPLE: DUT uses password policy to set rules for password length, type of characters used (allowed and disallowed characters), complexity (character groups), and denied passwords (deny-list of passwords that cannot be set). Candidate password that does not conform to rules are chosen for this test. As password policy may be complex set of rules, multiple candidate passwords are tested to fully cover possible password policy violations. + +##### Expected results + +In context of each of the services using password-based authentication, applied password policy are effectively enforced and non-compliant passwords are rejected by DUT during password change. Applicable to local services and to remotely accessible services. + +**Expected format of evidence:** Report file, log files and/or screenshots. + +## 7.4 Network Protocol Fuzzing + +Fuzzing is an automated process of sending invalid or random inputs to a SUT to cause it to malfunction or crash. + +Fuzzing is effective for finding vulnerabilities because while most modern programs have extensive input fields, the test coverage of these areas is relatively small. Even though this process can be a powerful capability to ensure robustness, it needs to be sufficiently defined and implemented throughout the system development lifecycle to be helpful and achieve the required results in a multi-vendor environment. + +While traditional fuzzing techniques involve fuzzing piece(s) of software and generating inputs through command line or input files, fuzzing telecommunication network protocols tends to be different, requiring sending information via network ports. Furthermore, the complex nature of network protocols in the SUT resulting from how they are layered over each other adds to the challenges of fuzzing such SUTs. + +The following are examples of the protocols that fuzzing will cover; + +| General Transport Protocols | +|-----------------------------| +| SCTP | +| IP | +| TCP | +| UDP | +| SSH | +| HTTP | +| HTTP/2 | + +and + +| O-RAN Specific Protocols | +|--------------------------| +| NETCONF | +| E1AP | +| E2AP | +| A1 | +| CTI | +| eCPRI | +| PTP | + +It is anticipated that many O-RAN architecture elements utilize common software frameworks used for the lower-level general communication. In this case it should be evaluated if these General Transport Protocols are being tested in extensive Fuzzing tests in other activities and can therefore be considered to have lower risk profiles compared to the O-RAN Specific Protocols with less testing in the general industry. + +Many of the O-RAN specific protocols are state- machine based protocols that can have multiple end points served at the same time, e.g. the protocol needs to be tested in scale to understand if possible memory leaks or other similar aspects is available that could lead to buffer overflows (opening up for possible code execution) or software crashes of the O-RAN specific software. + +Fuzzing on the M-Plane protocol inside the Configuration of the O-RAN Fronthaul can be a possible significant area as this is combining multiple technologies from many domains into a single solution. In order for the Fuzzing to be time and resource efficient, it is important that this Fuzzing is protocol and state machine aware so that the Fuzzing can focus on the relevant aspects of the SUT representing the most significant risk exposure. Further effectiveness can be achieved if the Fuzzing capability is able to intelligently respond to the SUT behaviour. The Fuzzing tool should be able to both perform test with and without access to relevant credentials. Many possible vulnerabilities would be present on the inside of the authenticated session of the management protocols and would lead to escalation of privileges. + +In order to identify the possible risk for memory leaks, Denial of Service (DoS) or other similar aspects a robust logging of the underlying platform (hardware and software), the virtualization or container platform and the O-RAN function, the logging needs to be detailed enough to evaluate the trends early but not intrusive to degrade the performance of the platform and lead to inaccurate results. + +As general guidance, vendors and operators running fuzzing tests aim to document the list of all of the protocols of the SUTs reachable externally on an IP-based interface, together with indications of whether adequate available robustness and fuzz testing tools have been used against them. The tool's name, their unambiguous version (also for plug-ins if applicable), user settings, and the relevant output evidenced and should be documented. Additionally, any input causing unspecified, undocumented, or unexpected behaviour and a description of this behaviour should be highlighted in the testing documentation. + +Since fuzzing test cases are not exhaustive and difficult to define and replicate, it's likely that test results even from testing the same set of protocols by different vendors may end up resulting in different outputs. So further effort and time needs to be invested in fuzzing activities until a satisfactory approach based on the vendor's or/and operators adopted risk-based model is satisfied. + +## 7.5 Denial of Service/Message Flooding + +### 7.5.1 Protocol, Application and Volumetric Based DDoS Attacks + +**Requirement Name:** Robustness against Volumetric DDoS Attack + +**Requirement Reference:** REQ-SEC-DOS-1, clause 5.3.5.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** “An O-RAN component with external network interface shall be able to withstand network transport protocol based volumetric DDoS attack without system crash and returning to normal service level after the attack” + +**Threat References:** T-O-RAN-04, T-O-RAN-09, T-SMO-03 + +**DUT/s:** Components implementing O-RAN interfaces defined in clause 5.1 of this document. + +**Test Name:** TC\_Robustness\_DDoS + +**Purpose:** To verify the DUT is able to recover from a DDoS attack. + +#### Procedure and execution steps + +Each component interface is tested to validate how handling of large amounts of requests is done, similar to what is seen from denial of service (DoS) or/and distributed denial of service (DDoS) attempts. DoS/DDoS scenario can be occurred as a result of malicious attack or because of network/operator error. DoS/DDoS attacks may come in these forms: Protocol layer attacks (e.g. SYN Floods, UDP Floods, TCP Floods), Volume based attacks (e.g. ICMP floods, Smurf DDoS) and Application layer attacks (e.g. GET/POST floods, low-and-slow attacks, attacks that target specific software – application with exposed network services or operating system network services). + +#### Preconditions + +This test is executed against running O-RAN component or O-RAN system as the DUT. + +Test prerequisites: + +- Network access to DUT +- Vendor-provided list of network protocols and services supported by DUT + +#### Execution steps + +1. In case the call flow needs authentication: + - 1.1. Set up a call flow that will send repeated requests after the authentication at an increasing rate over time. Mark the failure point of receiving rejection or response messages. + - 1.2. Stop the attack. + - 1.3. Set up a call flow that will send repeated requests before the authentication at an increasing rate over time. Mark the failure point of receiving acceptance or response messages. + - 1.4. Stop the attack. +2. In case the call flow does not need authentication: + - 2.1. Set up a call flow that will send repeated requests at an increasing rate over time. Mark the failure point of receiving response messages. + - 2.2. Stop the attack. + +#### Expected results + +It is expected the component fails to serve requests after step 1.1, 1.3 and/or step 2.1. + +After the attack/test stops, the DUT returns to a functional state, being able to respond to service requests again. + +This test case fails if DUT does not return to a functional state after the test stops. + +**Expected format of evidence:** Report file, log files and/or screenshots. + +## 7.5.2 Void + +## 7.5.3 Void + +## 7.5.4 Void + +## 7.5.5 Near-RT RIC A1 interface DoS/DDoS protection and recovery + +**Requirement Name:** Near-RT RIC DoS/DDoS protection and recovery + +**Requirement Reference:** REQ-SEC-NEAR-RT-6, REQ-SEC-NEAR-RT-7, clause 5.1.3, REQ-SEC-DOS-1, clause 5.3.5 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-04, T-O-RAN-09 + +**DUT/s:** Near-RT RIC + +**Test Name:** TC\_DoS\_RECOV\_NEAR\_RT\_RIC + +**Purpose:** The purpose of this test is to evaluate the resilience of the Near-RT RIC against Denial-of-Service/Distributed-Denial-of-Service attacks on the A1 interface and the recovery process from those attacks. + +### Procedure and execution steps + +#### Preconditions + +- The Near-RT RIC is powered on and operational. +- DoS/DDoS protection mechanisms are implemented on the Near-RT RIC. +- The testing environment is isolated and does not impact production systems. +- Refer to TC\_Robustness\_DDOS. + +#### Execution steps + +1. In case the call flow needs authentication: + - 1.1. Set up a call flow that will send repeated requests to the exposed A1 interface end point after the authentication at an increasing rate over time. Mark the failure point of receiving rejection or response messages. + - 1.2. Stop the attack. + - 1.3. Set up a call flow that will send repeated requests to the exposed A1 interface end point before the authentication at an increasing rate over time. Mark the failure point of receiving acceptance or response messages. + +1.4. Stop the attack. + +2. In case the call flow does not need authentication: + +2.1. Set up a call flow that will send repeated requests to the exposed A1 interface end point at an increasing rate over time. Mark the failure point of receiving response messages. + +2.2. Stop the attack. + +### Expected Results + +- Near-RT RIC detects and demonstrates robustness against the DoS/DDoS attack on A1 interface, maintaining normal operations with acceptable performance and rejecting requests, regardless of whether they are malicious or not. +- Near-RT RIC successfully recovers from the DoS/DDoS attack on A1 interface and resumes normal operation within a reasonable recovery time. + +### Expected format of evidence: + +- Observation logs during the DoS/DDoS attack, including any triggered countermeasures or rate limiting mechanisms, and validate that the Near-RT RIC effectively defends against the attack. +- Observation logs of the recovery process, including the time taken for the Near-RT RIC to regain stable operation, and validate that the recovery is timely and effective. + +NOTE: Recovery time specifies the maximum acceptable recovery time after the attack ceases (e.g., "Near-RT RIC recovers and returns to normal operation within 5 minutes after the attack stops"). + +## 7.6 Input validation and error handling + +Input validation and error handling are pivotal security practices that guard against malformed or malicious data inputs, ensuring that systems behave predictably and securely. This clause elucidates a series of tests designed to validate the efficacy of the input validation and error handling mechanisms implemented in various O-RAN network functions (O-CU, O-DU, Near-RT RIC), safeguarding them from a myriad of potential vulnerabilities and ensuring robust, secure, and stable operations. + +### 7.6.1 O-CU input validation and error handling + +**Requirement Name:** Input validation and error handling on data provided through O1 and E2 interfaces. + +**Requirement Reference:** REQ-SEC-OCU-1, clause 5.1.4 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05 + +**DUT/s:** O-CU + +**Test Name:** TC\_INPUT\_VALIDATION\_ERR\_HANDL\_OCU + +**Purpose:** The purpose of this test is to verify that the O-CU performs proper input validation on provided data via E2/O1 interfaces and rejects invalid or malicious inputs. It verifies that the O-CU correctly handles errors and responds appropriately. + +**Procedure and execution steps** + +**Preconditions** + +- The O-CU is powered on and operational. + +- Test environment is set up with E2 and O1 interfaces configured. +- Input validation mechanisms are implemented on O-CU. +- Error handling mechanisms (e.g., error codes, error messages) are implemented by O-CU. + +#### Execution steps + +1. Case of malformed input data + - a) The tester provides invalid or malformed input data to the O-CU via E2/O1 interfaces, violating the specified format or containing unexpected values. + - b) The tester captures and analyses the response from the E2/O1 interfaces. + - c) The tester verifies that the O-CU detects the invalid input and rejects it appropriately, returning an error message or taking necessary actions to mitigate the impact. + +EXAMPLE: actions could be rejecting the message, sending an error indication, etc. + +2. Case of malicious input data + - a) The tester provides malicious input data to the O-CU, aiming to exploit known vulnerabilities (e.g., CVE database, OWASP Top Ten, NIST National Vulnerability Database (NVD), vendor-specific vulnerability database) or perform unauthorized actions. + - b) The tester verifies that the O-CU identifies the malicious input and implements security measures to prevent exploitation, such as input sanitization, access controls, or anomaly detection. +3. Boundary case + - a) Provide input data at the boundaries of the allowed range or limits defined for specific inputs. + - b) Verify that the O-CU handles the boundary cases correctly, without encountering any unexpected behaviour or errors due to boundary conditions. + +#### Expected Results + +1. For case 'malformed input data', the O-CU properly validates incoming inputs from O1/E2 interfaces and rejects those with invalid or malformed data, returning an appropriate error response and preventing any potential security risks or system failures. +2. For case 'malicious input data', the O-CU detects and mitigates the malicious input, preventing any potential security breaches or unauthorized operations. +3. For case 'boundary', the O-CU properly handles the boundary cases, ensuring that inputs at the limits are processed accurately without causing any system instability or vulnerabilities. + +#### Expected format of evidence: + +1. Logs detailing the invalid or malformed input data provided to the O-CU via O1/E2 interfaces, alongside system logs capturing the O-CU's error messages or indications in response to the invalid input. +2. Logs documenting the malicious input data sent to the O-CU and the targeted vulnerabilities, complemented by system logs highlighting the O-CU's detection and mitigation actions upon receiving the malicious input. +3. Logs of the boundary input data values provided to the O-CU, paired with system logs capturing the O-CU's messages or behaviours in response to the boundary inputs. + +## 7.6.2 O-DU input validation and error handling + +**Requirement Name:** Input validation and error handling on data provided through O1/E2/FH interfaces. + +**Requirement Reference:** REQ-SEC-ODU-1, clause 5.1.5 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05 + +**DUT/s:** O-DU + +**Test Name:** TC\_INPUT\_VALIDATION\_ERR\_HANDL\_ODU + +**Purpose:** The purpose of this test is to verify that the O-DU performs proper input validation on provided data via E2/O1/FH interfaces and rejects invalid or malicious inputs. It verifies that the O-DU correctly handles errors and responds appropriately. + +### Procedure and execution steps + +#### Preconditions + +- The O-DU is powered on and operational. +- Test environment is set up with E2/O1/FH interfaces configured. +- Input validation mechanisms are implemented on O-DU. +- Error handling mechanisms (e.g., error codes, error messages) are implemented by O-DU. + +#### Execution steps + +##### 1. Case of malformed input data + +- a) The tester provides invalid or malformed input data to the O-DU via E2/O1/FH interfaces, violating the specified format or containing unexpected values. +- b) The tester captures and analyses the response from the E2/O1/FH interfaces. +- c) The tester verifies that the O-DU detects the invalid input and rejects it appropriately, returning an error message or taking necessary actions to mitigate the impact. + +EXAMPLE: actions could be rejecting the message, sending an error indication, etc. + +##### 2. Case of malicious input data + +- a) The tester provides malicious input data to the O-DU, aiming to exploit known vulnerabilities (e.g., CVE database, OWASP Top Ten, NIST National Vulnerability Database (NVD), vendor-specific vulnerability database) or perform unauthorized actions. +- b) The tester verifies that the O-DU identifies the malicious input and implements security measures to prevent exploitation, such as input sanitization, access controls, or anomaly detection. + +##### 3. Boundary case + +- a) Provide input data at the boundaries of the allowed range or limits defined for specific inputs. +- b) Verify that the O-DU handles the boundary cases correctly, without encountering any unexpected behaviour or errors due to boundary conditions. + +#### Expected Results + +1. For case 'malformed input data', the O-DU properly validates incoming inputs from O1/E2/FH interfaces and rejects those with invalid or malformed data, returning an appropriate error response and preventing any potential security risks or system failures. +2. For case 'malicious input data', the O-DU detects and mitigates the malicious input, preventing any potential security breaches or unauthorized operations. + +3. For case 'boundary', the O-DU properly handles the boundary cases, ensuring that inputs at the limits are processed accurately without causing any system instability or vulnerabilities. + +#### Expected format of evidence: + +1. Logs detailing the invalid or malformed input data provided to the O-DU via E2/O1/FH interfaces, alongside system logs capturing the O-DU's error messages or indications in response to the invalid input. +2. Logs documenting the malicious input data sent to the O-DU and the targeted vulnerabilities, complemented by system logs highlighting the O-DU's detection and mitigation actions upon receiving the malicious input. +3. Logs of the boundary input data values provided to the O-DU, paired with system logs capturing the O-DU's messages or behaviours in response to the boundary inputs. + +### 7.6.3 Near-RT RIC input validation and error handling + +**Requirement Name:** Error handling by Near-RT RIC + +**Requirement Reference:** REQ-SEC-NEAR-RT-6, REQ-SEC-NEAR-RT-7, clause 5.1.3 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-NEAR-RT-03, T-NEAR-RT-04 + +**DUT/s:** NEAR-RT RIC + +**Test Name:** TC\_INPUT\_VALIDATION\_ERR\_HANDL\_NEAR\_RT\_RIC + +**Purpose:** The purpose of this test is to verify that the Near-RT RIC performs proper input validation on provided data via O1/E2/A1/Y1 interfaces and rejects invalid or malicious inputs. It verifies that the Near-RT RIC correctly handles errors and responds appropriately. + +#### Procedure and execution steps + +##### Preconditions + +1. Near-RT RIC is powered and operational. +2. Test environment is set up with O1/E2/A1/Y1 interfaces configured. +3. Input validation mechanisms are implemented on Near-RT RIC. +4. Error handling mechanisms (e.g., error codes, error messages) are implemented by Near-RT RIC. + +##### Execution steps + +1. Case of malformed input data + - a) The tester provides invalid or malformed input data to the Near-RT RIC via O1/E2/A1/Y1 interfaces, violating the specified format or containing unexpected values. + - b) The tester captures and analyses the response from the O1/E2/A1/Y1 interfaces. + - c) The tester verifies that the Near-RT RIC detects the invalid input and rejects it appropriately, returning an error message or taking necessary actions to mitigate the impact. + +EXAMPLE: actions could be rejecting the message, sending an error indication, etc. + +2. Case of malicious input data + - a) The tester provides malicious input data to the Near-RT RIC, aiming to exploit known vulnerabilities (e.g., CVE database, OWASP Top Ten, NIST National Vulnerability Database (NVD), vendor-specific vulnerability database) or perform unauthorized actions. + +- b) The tester verifies that the Near-RT RIC identifies the malicious input and implements security measures to prevent exploitation, such as input sanitization, access controls, or anomaly detection. +3. Boundary case + - a) Provide input data at the boundaries of the allowed range or limits defined for specific inputs. + - b) Verify that the Near-RT RIC handles the boundary cases correctly, without encountering any unexpected behaviour or errors due to boundary conditions. + +### Expected Results + +1. For case 'malformed input data', the Near-RT RIC properly validates incoming inputs from O1/E2/A1/Y1 interfaces and rejects those with invalid or malformed data, returning an appropriate error response and preventing any potential security risks or system failures. +2. For case 'malicious input data', the Near-RT RIC detects and mitigates the malicious input, preventing any potential security breaches or unauthorized operations. +3. For case 'boundary', the Near-RT RIC properly handles the boundary cases, ensuring that inputs at the limits are processed accurately without causing any system instability or vulnerabilities. + +### Expected format of evidence: + +1. Logs detailing the invalid or malformed input data provided to the Near-RT RIC via O1/E2/A1/Y1 interfaces, alongside system logs capturing the Near-RT RIC's error messages or indications in response to the invalid input. +2. Logs documenting the malicious input data sent to the Near-RT RIC and the targeted vulnerabilities, complemented by system logs highlighting the Near-RT RIC 's detection and mitigation actions upon receiving the malicious input. +3. Logs of the boundary input data values provided to the Near-RT RIC, paired with system logs capturing the Near-RT RIC 's messages or behaviours in response to the boundary inputs. + +## 7.6.4 Near-RT RIC input validation and error handling of data received from xApp + +**Requirement Name:** Error handling by Near-RT RIC + +**Requirement Reference:** SEC-CTL-NEAR-RT-18, clause 5.1.3.2 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** The Near-RT RIC shall verify data received through E2 related APIs initiated by xApp as follows: + +The data values are valid. + +The Near-RT RIC shall log security event(s) if any of the verification steps fail. + +**Threat References:** T-NEAR-RT-03, T-NEAR-RT-04 + +**DUT/s:** NEAR-RT RIC + +**Test Name:** TC\_E2API\_INPUT\_VALIDATION\_ERR\_HANDL\_NEAR\_RT\_RIC\_XAPP + +**Purpose:** The purpose of this test is to verify that the Near-RT RIC performs proper input validation on received data from xApp through E2 related APIs and rejects malformed inputs. It verifies that the Near-RT RIC correctly handles errors and responds appropriately. + +### Procedure and execution steps + +### Preconditions: + +- Near-RT RIC is deployed. + - A testing software that supports communication with Near-RT RIC over E2 related APIs [27]. + - Error handling mechanisms are implemented by Near-RT RIC. +- EXAMPLE: E2 Error or Failure message with Cause as defined in clause 9.2.1 of [28]. + +### Execution Steps: + +1. Malformed input data + - a. Provide malformed input data to the Near-RT RIC via E2 related APIs, violating the specified format. + +EXAMPLE: Input data containing unknown IEs, incorrect format and mandatory IEs not present. + + - b. Capture and analyze the response from Near-RT RIC via E2 related APIs. + - c. Verify that the Near-RT RIC detects the malformed input and rejects it appropriately, returning an error message or taking necessary actions to mitigate the impact. + +EXAMPLE: Actions could be rejecting the message, sending an error rejection or failure indication, etc. +2. Valid and Invalid boundary cases + - a. Provide invalid (wrong value) data outside of the boundaries or limits of the acceptable values or ranges defined for specific parameters in clause 5.2.2 & 5.2.3, O-RAN E2 Interface Test Specification [29] for E2 related APIs. + - b. Provide valid data at the boundaries or inside the allowed ranges defined for specific parameters in clause 5.2.2 & 5.2.3, O-RAN E2 Interface Test Specification [29] for E2 related APIs. + - c. Verify that the Near-RT RIC handles these boundary cases correctly, without encountering any unexpected behaviour or errors due to boundary conditions. + +### Expected Results: + +1. Malformed input data + - a. The Near-RT RIC properly validates incoming inputs via E2 related APIs from xApp and rejects those with malformed data, returning an appropriate error response. +2. Valid and Invalid boundary cases + - a. The Near-RT RIC properly handles the valid and invalid boundary cases. + +### Expected format of evidence: + +1. Malformed input data + - a. Logs detailing the malformed input data provided to the Near-RT RIC via E2 related APIs, alongside system logs capturing the Near-RT RIC's error messages. +2. Valid and Invalid boundary cases + - a. Logs of the input data values provided to the Near-RT RIC, paired with system logs capturing the Near-RT RIC's messages or behaviours in response to the boundary inputs. + +## 7.7 Secure configuration enforcement + +**Requirement Name:** O-CU configuration security enforcement + +**Requirement Reference:** SEC-CTL-OCU-1, clause 5.1.4.2, SEC-CTL-ODU-1, clause 5.1.5.2, ,REQ-SEC-ORU-1, clause 5.1.6.1 in O-RAN Security Requirements and Controls Specifications [5], 3GPP TS 33.501 clause 5.3.4 [25] + +**Requirement Description:** The DUT ensures that settings and software configurations are protected from unauthorized modifications. + +**Threat Reference:** T-O-RAN-02 + +**DUT/s:** O-CU, O-DU, O-RU + +**Test Name:** TC\_CONF\_ENFORCEMENT + +**Purpose:** Ensure the DUT prevents unauthorized settings and software configurations changes, as required by 3GPP TS 33.501 clause 5.3.4 [25]. + +#### Procedure and execution steps + +##### Preconditions: + +1. The DUT is powered on and operational. +2. Settings and software configurations are defined and applied on the DUT. +3. Successful access to the DUT is established. + +##### Execution steps: + +1. Attempt to modify the DUT settings and software configurations with proper authorization. +2. Verify that the DUT detects and accepts any authorized modification attempts. +3. Attempt to modify the DUT settings and software configurations without proper authorization. +4. Verify that the DUT detects and rejects any unauthorized modification attempts. + +##### Expected results: + +- DUT accepts authorized modifications. +- DUT detects and rejects any unauthorized modifications. + +##### Expected format of evidence: + +- Logs indicating the detection and acceptance of authorized modifications. +- Logs indicating the detection and rejection of unauthorized modifications. + +EXAMPLE: examples of settings and software configurations include: + +Security configuration: e.g., protocols and keys used for authentication, authorization, and secure communication. + +Software management: e.g., current software version + +Interface settings + +## 7.8 Logging and monitoring + +The tests outlined here aim to scrutinize the logging and monitoring capabilities of various O-RAN components, ensuring they are up to the mark and can effectively detect, log, and alert any anomalies. + +### 7.8.1 O-CU logging and monitoring + +**Requirement Name:** O-CU logging and monitoring + +**Requirement Reference:** REQ-SEC-OCU-1, clause 5.1.4 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-07 + +**DUT/s:** O-CU + +**Test Name:** TC\_LOG\_OCU + +**Purpose:** The purpose of this test is to verify that the O-CU correctly logs and monitors security-related events effectively. + +### Procedure and execution steps + +#### Preconditions + +- The O-CU is powered on and operational. +- Logging and monitoring configurations are properly set up on the O-CU. + +#### Execution steps + +1. Logging + - a) The tester triggers an error or failure condition in the O-CU, such as connection attempts with invalid credentials, unauthorized access and a dropped connection. + - b) The tester verifies that the O-CU logs the error by capturing the relevant log entry. +2. Monitoring + - a) The tester monitors the key performance indicators (KPIs) of the O-CU, such as throughput, latency, or signal quality. + - b) The tester verifies that the monitoring system accurately collects and displays the KPI values in real-time. + - c) The tester introduces a simulated degradation or overload scenario on the O-CU, such as increasing network traffic or reducing available resources. + - d) The tester monitors the O-CU performance under the simulated scenario. + - e) The tester verifies that the monitoring system detects and raises alerts for the degraded performance or overload condition. + +#### Expected Results + +1. O-CU logs and generates alerts for security-related events, providing necessary information and timestamps for incident investigation and analysis. +2. The monitoring system provides accurate and real-time KPI values for the O-CU. The monitoring system detects and raises appropriate alerts for the degraded performance or overload condition. + +#### Expected format of evidence: + +1. Capture and analyse the logged error in the O-CU logs or logging system and document the presence of the log entry. +2. Document the monitored KPI values and the raised alerts, validate them against the expected values, and ensure they are triggered accurately in the monitoring system. + +## 7.8.2 O-DU logging and monitoring + +**Requirement Name:** O-DU logging and monitoring + +**Requirement Reference:** REQ-SEC-ODU-1, clause 5.1.5 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-07 + +**DUT/s:** O-DU + +**Test Name:** TC\_LOG\_ODU + +**Purpose:** The purpose of this test is to ensure that the O-DU correctly logs and monitors security-related events effectively. + +### Procedure and execution steps + +#### Preconditions + +- The O-DU is powered on and operational. +- Logging and monitoring configurations are properly set up on the O-DU. + +#### Execution steps + +1. Logging + - a) The tester triggers an error or failure condition in the O-DU, such as connection attempts with invalid credentials, unauthorized access and a dropped connection. + - b) The tester verifies that the O-DU logs the error by capturing the relevant log entry. +2. Monitoring + - a) The tester monitors the key performance indicators (KPIs) of the O-DU, such as throughput, latency, or signal quality. + - b) The tester verifies that the monitoring system accurately collects and displays the KPI values in real-time. + - c) The tester introduces a simulated degradation or overload scenario on the O-DU, such as increasing network traffic or reducing available resources. + - d) The tester monitors the O-DU performance under the simulated scenario. + - e) The tester verifies that the monitoring system detects and raises alerts for the degraded performance or overload condition. + +#### Expected Results + +1. O-DU logs and generates alerts for security-related events, providing necessary information and timestamps for incident investigation and analysis. +2. The monitoring system provides accurate and real-time KPI values for the O-DU. The monitoring system detects and raises appropriate alerts for the degraded performance or overload condition. + +#### Expected format of evidence: + +1. Capture and analyse the logged error in the O-DU logs or logging system and document the presence of the log entry. + +2. Document the monitored KPI values and the raised alerts, validate them against the expected values, and ensure they are triggered accurately in the monitoring system. + +### 7.8.3 O-RU logging and monitoring + +**Requirement Name:** O-RU logging and monitoring + +**Requirement Reference:** REQ-SEC-ORU-1, REQ-SEC-ORU-2, clause 5.1.6 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-07 + +**DUT/s:** O-RU + +**Test Name:** TC\_LOG\_ORU + +**Purpose:** The purpose of this test is to ensure that the O-RU correctly logs and monitors security-related events effectively. + +#### Procedure and execution steps + +##### Preconditions + +- The O-RU is powered on and operational. +- Logging and monitoring configurations are properly set up on the O-RU. + +##### Execution steps + +1. Logging + - a) The tester triggers an error or failure condition in the O-RU, such as connection attempts with invalid credentials, unauthorized access and a dropped connection. + - b) The tester verifies that the O-RU logs the error by capturing the relevant log entry. +2. Monitoring + - a) The tester monitors the key performance indicators (KPIs) of the O-RU, such as throughput, latency, or signal quality. + - b) The tester verifies that the monitoring system accurately collects and displays the KPI values in real-time. + - c) The tester introduces a simulated degradation or overload scenario on the O-RU, such as increasing network traffic or reducing available resources. + - d) The tester monitors the O-RU performance under the simulated scenario. + - e) The tester verifies that the monitoring system detects and raises alerts for the degraded performance or overload condition. + +##### Expected Results + +1. O-RU logs and generates alerts for security-related events, providing necessary information and timestamps for incident investigation and analysis. +2. The monitoring system provides accurate and real-time KPI values for the O-RU. The monitoring system detects and raises appropriate alerts for the degraded performance or overload condition. + +##### Expected format of evidence: + +1. Capture and analyse the logged error in the O-RU logs or logging system and document the presence of the log entry. +2. Document the monitored KPI values and the raised alerts, validate them against the expected values, and ensure they are triggered accurately in the monitoring system. + +## 7.8.4 Near-RT RIC logging and monitoring + +**Requirement Name:** Near-RT RIC logging and monitoring + +**Requirement Reference:** REQ-SEC-NEAR-RT-4, clause 5.1.3 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-04 + +**DUT/s:** NEAR-RT RIC + +**Test Name:** TC\_LOG\_NEAR\_RT\_RIC + +**Purpose:** The purpose of this test is to ensure that the Near-RT RIC correctly logs and monitors security-related events effectively. + +### Procedure and execution steps + +#### Preconditions + +1. The Near-RT RIC is powered on and operational. +2. Logging and monitoring configurations are properly set up on the Near-RT RIC. + +#### Execution steps + +1. Logging + - a) The tester triggers an error or failure condition in the Near-RT RIC, such as connection attempts with invalid credentials, unauthorized access, or a dropped connection. + - b) The tester verifies that the Near-RT RIC logs the error by capturing the relevant log entry. +2. Monitoring + - a) The tester monitors the key performance indicators (KPIs) of the Near-RT RIC, such as throughput, latency, or signal quality. + - b) The tester verifies that the monitoring system accurately collects and displays the KPI values in real-time. + - c) The tester introduces a simulated degradation or overload scenario on the Near-RT RIC, such as increasing network traffic or reducing available resources. + - d) The tester monitors the Near-RT RIC performance under the simulated scenario. + - e) The tester verifies that the monitoring system detects and raises alerts for the degraded performance or overload condition. + +#### Expected Results + +1. Near-RT RIC logs and generates alerts for security-related events, providing necessary information and timestamps for incident investigation and analysis. + +2. The monitoring system provides accurate and real-time KPI values for the Near-RT RIC. The monitoring system detects and raises appropriate alerts for degraded performance or overload conditions. + +**Expected format of evidence:** + +1. Capture and analyse the logged error in the Near-RT RIC logs or logging system and document the presence of the log entry. +2. Document the monitored KPI values and the raised alerts, validate them against the expected values, and ensure they are triggered accurately in the monitoring system. + +--- + +## 8 System security evaluation for O-RAN architecture elements + +### 8.1 Overview + +This clause contains security evaluations to be performed at the system level of an O-RAN architecture element, covering vulnerability scanning, data and information protection and system logging. + +The objects in scope of these system security evaluation are SMO, Non-RT RIC and rApps, Near-RT RIC and rApps, O-CU-CP, O-CU-UP, O-DU, O-RU and O-Cloud. + +### 8.2 System Vulnerability Scanning + +#### 8.2.1 System Vulnerability Scanning + +**Requirement Name:** Robustness of OS and Applications + +**Requirement Reference:** REQ-SEC-SYS-1, clause 5.3.6, REQ-SEC-ALM-PKG-1, clause 5.3.2.1.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Operating System (OS) and applications vulnerability scan of DUT + +**Threat References:** T-O-RAN-01 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_Vulnerability\_Scanning + +**Purpose:** To verify the DUT does not contain known vulnerabilities in the OS and applications. Perform vulnerability scanning to ensure that there are no known vulnerabilities on DUT, both in the Operating System(OS) and the applications installed, that can be detected by means of automatic testing tools via the IP enabled network interfaces, or to identify the known vulnerabilities on DUT and have a clear mitigation plan for the ones of high severity. + +Known vulnerabilities are considered those which are publicly disclosed, found by users or reported by security researchers. Those vulnerabilities are widely detected by commercial, or open-source tools designed for this purpose. + +**Procedure and execution steps****Preconditions** + +DUT is the O-RAN architecture element with IP enabled network interfaces. + +**Execution steps** + +1. Run the vulnerability scanning tool and check the potential known vulnerabilities existing on OS and applications levels. +2. Evaluate the severity level of the existing vulnerabilities. + +**Expected results** + +The DUT is free from known vulnerabilities or there are security controls in place to mitigate the exploits associated with the vulnerabilities of high severity. + +**Expected format of evidence:** Report files, log files and/or screenshots. + +## 8.3 Data and Information Protection + +Void + +## 8.4 System logging + +### 8.4.1 Introduction + +This clause contains test cases related to security log management. + +### 8.4.2 Security log format and related log fields + +**Requirement Name:** Security logs check for date, time and location field IP address. + +**Requirement Reference:** SEC-CTL-SLM-FLD-1, SEC-CTL-SLM-FLD-2, clause 5.3.8.8, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Support for security logs containing date, time and location field IP address. + +**Threat References:** T-O-RAN-07 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_Logs\_Datetime\_Fields\_Validation + +**Purpose:** To verify the log fields of security log data from DUT as per clause 5.3.8.8 of Security Requirements and Controls specifications [5]. The security log has the recommended date and time in ISO 8601 format and mandatorily log the location field IP address (IP address of the host from which security events are generated). + +**Procedure and execution steps****Preconditions** + +DUT is any O-RAN architecture element that creates/generates security event logs which acts as server. DUT also offers one or more services through which it can be accessed. + +Client is the test system equipped to communicate securely with O-RAN architecture element and able to perform security related operations on DUT. + +**Execution steps** + +**Table 8-1 Test and measurement equipment list** + +| Scenario ID | Configuration | +|-------------|---------------------------------------------------------------------------------| +| 1 | Login to the DUT via test system with authorized credentials. | +| 2 | Execute valid operations on the DUT which triggers/generates the security logs. | + +**Expected results** + +**Table 8-2 Test and measurement equipment list** + +| Scenario ID | Expected result | Reason | +|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------| +| 1 | Connection established. | Authentication successful. | +| 2 | All the security logs generated by the DUT have:

    1] Date and time format as per ISO 8601 format as recommended by clause 5.3.8.8 of [5]

    2] Location field IP address (IP address of the DUT) as mandated by clause 5.3.8.8 of [5] | Security log generation is successful. | + +**Expected format of evidence:** Log files + +### 8.4.3 Authenticated Time Stamping + +**Requirement Name:** Authenticated Time-Stamping + +**Requirement Reference:** Clause 5.3.8.9.2.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Optional support NTPv4 + +**Threat References:** T-O-RAN-07 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_Logs\_Authenticated\_Time\_Stamping + +**Purpose:** To verify that the DUT fulfills the optional requirement of supporting Network Time Protocol (NTP) version 4 as specified by RFC5905 for authenticated time stamping in the client role only. + +**Procedure and execution steps** + +**Preconditions** + +1. The DUT is powered on and operational. +2. The NTP server specified for testing is reachable and configured to support authenticated time stamping. + +**Execution steps** + +Verify NTP Client Version: + +- Access the DUT configuration settings related to NTP. +- Confirm that the DUT specifies NTP version 4 as the selected protocol. + +Authentication Setup + +- Configure the DUT to use the necessary authentication methods and -credentials (AES-CMAC/RFC4493, certificates for Autokey/RFC5906) required by RFC5905 for authenticated time stamping. +- Provide valid authentication credentials (certificates) for NTP communication. + +#### Time Synchronization + +- Initiate an NTP time synchronization process from the DUT to the specified NTP server. +- Monitor the communication between the DUT and the NTP server to ensure that the NTP packets are properly constructed with the required authentication parameters. +- Verify that the DUT successfully receives the authenticated time stamps from the NTP server. + +#### Time Accuracy Check + +- After synchronization, record the DUT internal clock time. +- Obtain the time from the NTP server's authenticated time stamp. +- Calculate the time difference between the DUT internal clock time and the received authenticated time stamp. +- Ensure that the time difference is within an acceptable tolerance, considering network latency and authentication processing. + +#### Expected results + +The DUT fulfills the requirement of supporting Network Time Protocol (NTP) version 4 for authenticated time stamping, as specified by RFC5905. The NTP communication successfully employs the configured authentication methods, and the time synchronization process ensures accurate timekeeping within the specified tolerance. An accuracy below 1 second should be measured to pass. + +**Expected format of evidence:** Log files, traffic captures and/or screenshots. + +## 8.4.4 Network Security and System Security Events + +**Requirement Name:** Network Security Events to be Logged and System Security Events to be Logged. + +**Requirement Reference:** REQ-SEC-SLM-NET-EVT-1, REQ-SEC-SLM-GEN-EVT-1, REQ-SEC-SLM-GEN-EVT-2, REQ-SEC-SLM-GEN-EVT-3, REQ-SEC-SLM-HYP-EVT-1, REQ-SEC-SLM-HYP-EVT-2, REQ-SEC-SLM-HYP-EVT-3, REQ-SEC-SLM-CON-EVT-1, REQ-SEC-SLM-CON-EVT-2, REQ-SEC-SLM-CON-EVT-3. + +**Requirement Description:** Logging of network and system security events in O-Cloud + +**Threat References:** T-O-RAN-01, T-O-RAN-02, T-O-RAN-03, T-O-RAN-09, T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-VM-C-06, T-IMG-01, T-IMG-02, T-ADMIN-02. + +**DUT/s:** O-Cloud + +**Test Name:** TC\_Logs\_Network\_System\_Security\_Events + +**Purpose:** The purpose of the test is to verify the logging of security events from O-Cloud as per the Security Requirements and Controls Specifications [5]. + +#### Procedure and execution steps + +#### Preconditions + +A tester has access to testing equipment that can connect to the O-Cloud with administrative privileges to the operating system, hypervisor, and container engine. + +## Execution steps + +1. Login to the DUT via testing equipment with administrative credentials. +2. Execute the following operations on the DUT. + - 2.1. Create a new network configuration. + - 2.2. Modify an existing network configuration. + - 2.3. Disable a port. + - 2.4. Enable a port. + - 2.5. Generate packets that exceed configured firewall limits. + - 2.6. Generate at least one network connection. + - 2.7. Reboot a virtual machine and then reboot the host operating system. + - 2.8. Shutdown a virtual machine then shutdown the host operating system. + - 2.9. Create a scheduled job within the host operating systems, hypervisor, and container engine. + - 2.10. Make a configuration change to the host operating system and hypervisor. + - 2.11. Attach and detach a virtual disk to a virtual machine. + - 2.12. Create a virtual machine. + - 2.13. Start a virtual machine. + - 2.14. Stop a virtual machine. + - 2.15. Delete a virtual machine. + - 2.16. Add an image to the container repository. + - 2.17. Modify an image to the container repository. + - 2.18. Remove an image to the container repository. + - 2.19. Create a container. + - 2.20. Start a container. + - 2.21. Stop a container. + - 2.22. Restart a container. + - 2.23. Delete a container. + - 2.24. Create a container volume. + - 2.25. Mount a container volume. + - 2.26. Delete a container volume. + +## Expected results + +All the security logs produced by O-Cloud contain log messages that describe the actions taken in the execution steps. + +- For execution step 2.1 the log message indicates the creation of a new network configuration. +- For execution step 2.2 the log message indicates the modification of an existing network configuration. + +- For execution step 2.3 the log message indicates the disabling of a port. +- For execution step 2.4 the log message indicates the enabling a port. +- For execution step 2.5 the log message indicates that packets have exceeded configured firewall limits. +- For execution step 2.6 the log message indicates a network connection has been attempted along with details about that network connection including source and destination IP addresses. +- For execution step 2.7 the log message indicates that a virtual machine was rebooted, and a subsequent log message indicates that a host operating system has been rebooted. +- For execution step 2.8 the log message indicates that a virtual machine has been shut down and a subsequent log message indicates that the host operating system has been shut down. +- For execution step 2.9 the log message indicates that a scheduled job was created within the host operating system, a subsequent log message indicates that a scheduled job was created in the hypervisor, and a subsequent log message indicates that a scheduled job was created in the container engine. +- For execution step 2.10 the log message indicates that a configuration change was made to the host operating system and a subsequent log message indicates that a configuration change was made to the hypervisor. +- For execution step 2.11 the log message indicates that a virtual disk was attached to a virtual machine, and a subsequent log message indicates that a virtual disk was detached from a virtual machine. +- For execution step 2.12 the log message indicates that a virtual machine was created. +- For execution step 2.13 the log message indicates that a virtual machine was started. +- For execution step 2.14 the log message indicates that a virtual machine was stopped. +- For execution step 2.15 the log message indicates that a virtual machine was deleted. +- For execution step 2.16 the log message indicates that an image was added to the container repository. +- For execution step 2.17 the log message indicates that an image was modified in the container repository. +- For execution steps 2.18 the log message indicates that an image was removed from the container repository. +- For execution step 2.19 the log message indicates a container was created. +- For execution step 2.20 the log message indicates that a container was started. +- For execution step 2.21 the log message indicates that a container was stopped. +- For execution step 2.22 the log message indicated that a container was restarted. +- For execution step 2.23 the log message indicates that a container was deleted. +- For execution step 2.24 the log message indicates that a container volume was created. +- For execution step 2.25 the log message indicates that a container volume was mounted. +- For execution step 2.26 the log message indicates that a container volume was deleted. + +**Expected format of evidence:** Generated Log Files from DUT/s. + +## 8.4.5 Application Security Events + +**Requirement Name:** Application Security Events to be Logged. + +**Requirement Reference:** REQ-SEC-SLM-APP-EVT-1, REQ-SEC-SLM-APP-EVT-2. + +**Requirement Description:** Support for the logging of security events in network functions + +**Threat References:** T-OPENSRC-01, T-xAPP-01, T-xAPP-02, T-xAPP-03, T-xAPP-04, T-rAPP-01, T-rAPP-02, T-rAPP-03, T-rAPP-04, T-rAPP-05, T-rAPP-06, T-rAPP-07, T-PNF-01. + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_Logs\_Application\_Security\_Events + +**Purpose:** The purpose of the test is to verify the logging of security event data from O-RAN Network Functions as per the Security Requirements and Controls Specifications [5]. + +**Procedure and execution steps** + +**Preconditions** + +A tester has access to testing equipment that can connect to any O-RAN network function. + +### Execution steps + +NOTE 1: Execution steps not applicable to the DUT may be skipped. + +1. Login to the DUT via test equipment with authorized credentials. +2. Conduct an operation on the DUT that is known to generate an error. +3. Conduct an operation on the DUT that is known to load a dynamic library. + +### Expected results + +All the security logs produced by O-RAN Network Functions contain log messages that pertain to the actions taken in the execution steps. + +- For execution step 2 the log message contains an error message. +- For execution step 3 the log message contains a message indicating that a dynamic library loaded and details about that library. + +**Expected format of evidence:** Generated Log Files from DUT/s. + +## 8.4.6 Data Access Security Events + +**Requirement Name:** Data Access Security Events to be Logged. + +**Requirement Reference:** REQ-SEC-SLM-DAT-EVT-1, REQ-SEC-SLM-DAT-EVT-2, REQ-SEC-SLM-DAT-EVT-3, REQ-SEC-SLM-DAT-EVT-4, REQ-SEC-SLM-DAT-EVT-5, REQ-SEC-SLM-DAT-EVT-6, REQ-SEC-SLM-DAT-EVT-7, REQ-SEC-SLM-DAT-EVT-8. + +**Requirement Description:** Logging of data access security events. + +**Threat References:** T-VM-C-01, T-NEAR-RT-03, T-O-RAN-07, T-O-RAN-08, T-GEN-05 + +**DUT/s:** SMO, Non-RT RIC, Near-RT RIC, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_Logs\_Data\_Access\_Security\_Events + +**Purpose:** The purpose of the test is to verify the logging of data access security events as per the O-RAN Security Requirements and Controls Specifications [5]. + +### Procedure and execution steps + +#### Preconditions + +A tester has access to testing equipment that can communicate securely with the DUT and is able to perform security and administrative related operations. + +#### Execution steps + +NOTE 1: Execution steps not applicable to the DUT may be skipped. + +1. Login to the DUT via testing equipment with authorized credentials. +2. Execute the following operations on the DUT. + - 2.1. Add a new file. + - 2.2. Delete an existing file. + - 2.3. Attempt to add a file where you are not authorized to do so. + +- 2.4. Attempt to delete a file where you are not authorized to do so. +- 2.5. Read an existing file. +- 2.6. Write to an existing file. +- 2.7. Attempt to read to a file where you are not authorized to do so. +- 2.8. Attempt to write to a file where you are not authorized to do so. +- 2.9. Create a new directory. +- 2.10. Delete an existing directory. +- 2.11. Attempt to create a directory where you are not authorized to do so. +- 2.12. Attempt to delete a directory where you are not authorized to do so. +- 2.13. Add data to a datastore or database. +- 2.14. Delete data from a datastore or database. +- 2.15. Attempt to add data to a datastore or database where you are not authorized to do so. +- 2.16. Attempt to delete data from a datastore or database where you are not authorized to do so. +- 2.17. Read data from a datastore or database. +- 2.18. Write data from a datastore or database. +- 2.19. Attempt to read data from a datastore or database where you are not authorized to do so. +- 2.20. Attempt to write data to a datastore or database where you are not authorized to do so. +- 2.21. Make a permissions change to a file. +- 2.22. Make a permissions change to a directory. +- 2.23. Make a permissions change to a datastore or database. + +### Expected results + +All the security logs produced by O-RAN architecture elements contain log messages that document appropriately the actions taken in the execution steps. + +- For execution step 2.1 the log message indicates that a new file was added. +- For execution step 2.2 the log message indicates an existing file was deleted. +- For execution step 2.3 the log message indicates an unauthorized attempt to add a file. +- For execution step 2.4 the log message indicates an unauthorized attempt to delete a file. +- For execution step 2.5 the log message indicates an existing file was read. +- For execution step 2.6 the log message indicates an existing file was written. +- For execution step 2.7 the log message indicates an unauthorized attempt to read to a file. +- For execution step 2.8 the log message indicates an unauthorized attempt to write to a file. +- For execution step 2.9 the log message indicates a new directory was created. +- For execution step 2.10 the log message indicates an existing directory was deleted. +- For execution step 2.11 the log message indicates an unauthorized attempt to create a directory. +- For execution step 2.12 the log message indicates an unauthorized attempt to delete a directory. +- For execution step 2.13 the log message indicates data was added to a datastore or database. +- For execution step 2.14 the log message indicates data was deleted from a datastore or database. +- For execution step 2.15 the log message indicates an unauthorized attempt to add data to a datastore or database. + +- For execution step 2.16 the log message indicates an unauthorized attempt to delete data from a datastore or database. +- For execution step 2.17 the log message indicates that data was read from a datastore or database. +- For execution step 2.18 the log message indicates that data was written to a datastore or database. +- For execution step 2.19 the log message indicates an unauthorized attempt to read data from a datastore or database. +- For execution step 2.20 the log message indicates an unauthorized attempt to write data to a datastore or database. +- For execution step 2.21 the log message indicates a permissions change to a file. +- For execution step 2.22 the log message indicates a permissions change to a directory. +- For execution step 2.23 the log message indicates a permissions change to a datastore or database. + +**Expected format of evidence:** Generated Log Files from DUT. + +## 8.4.7 Account and Identity Security Events + +**Requirement Name:** Account and Identity Security Events to be Logged. + +**Requirement Reference:** REQ-SEC-SLM-AAI-EVT-1, REQ-SEC-SLM-AAI-EVT-2, REQ-SEC-SLM-AAI-EVT-3, REQ-SEC-SLM-AAI-EVT-4, REQ-SEC-SLM-AAI-EVT-5, REQ-SEC-SLM-AAI-EVT-6, REQ-SEC-SLM-AAI-EVT-7, REQ-SEC-SLM-AAI-EVT-9, REQ-SEC-SLM-AAI-EVT-10. + +**Requirement Description:** Logging of account and identity security events. + +**Threat References:** T-GEN-02, T-O-RAN-02, T-O-RAN-06, T-O-RAN-07, T-ProtocolStack-02, T-SMO-02, T-SMO-05, T-SMO-08, T-SMO-25, T-SMO-30, T-NEAR-RT-03. + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_Logs\_Account\_and\_Identity\_Security\_Events + +**Purpose:** The purpose of the test is to verify the logging of account and identity access security events as per O-RAN Security Requirements and Controls Specifications [5] + +### Procedure and execution steps + +#### Preconditions + +A tester will have access to testing equipment that can communicate securely with the DUT and is able to perform security and administrative related operations. + +#### Execution steps + +NOTE 1: Execution steps not applicable to the DUT may be skipped. + +1. Login to the DUT via testing equipment with authorized credentials. +2. Execute the following operations on the DUT. + - 2.1. Create an account. + - 2.2. Modify an existing account. + - 2.3. Delete an existing account. + - 2.4. Attempt to create an account where you are not authorized to do so. + - 2.5. Change the privilege level of an existing account from a lower privilege to a higher privilege. + - 2.6. Attempt to change the privilege level of an existing account where you are not authorized to do so. + - 2.7. Change the group membership of an existing account. + +- 2.8. Attempt to change the group membership of an existing account where you are not authorized to do so. +- 2.9. Use a function in the DUT that requires a specific authorization that you have been assigned. +- 2.10. Attempt to use a function in the DUT that requires a specific authorization that you have not been assigned. +- 2.11. Authenticate an account to the DUT that has been configured to access that DUT. +- 2.12. Attempt to authenticate an account to the DUT that has not been configured to access that DUT. +- 2.13. Change the privilege level of an existing account from a higher privilege to a lower privilege. +- 2.14. Access the DUT with an account the does not require authentication. +- 2.15. End a session with the DUT. + +### Expected results + +All the security logs produced by O-RAN architecture elements contain log messages that document appropriately the actions taken in the execution steps. + +- For execution step 2.1 the log message indicates that an account was created. +- For execution step 2.2 the log message indicates that an existing account was modified. +- For execution step 2.3 the log message indicates that an existing account was deleted. +- For execution step 2.4 the log message indicates an unauthorized attempt to create an account. +- For execution step 2.5 the log message indicates a privilege level change of an existing account from a lower privilege to a higher privilege. +- For execution step 2.6 the log message indicates an unauthorized attempt to change the privilege level of an existing account. +- For execution step 2.7 the log message indicates that the group membership had changed for an existing account. +- For execution step 2.8 the log message indicates an unauthorized attempt to change the group membership of an existing account. +- For execution step 2.9 the log message indicates the use of a restricted function. +- For execution step 2.10 the log message indicates an unauthorized attempt to use a restricted function. +- For execution step 2.11 the log message indicates the successful authentication of an account. +- For execution step 2.12 the log message indicates the unsuccessful attempt to authenticate an account. +- For execution step 2.13 the log message indicates a privilege level change of an existing account from a higher privilege to a lower privilege. +- For execution step 2.14 the log message indicates access with an account the does not require authentication. +- For execution step 2.15 the log message indicates the end of a session. + +**Expected format of evidence:** Generated Log Files from DUT. + +## 8.4.8 General Security Events + +**Requirement Name:** General Security Events to be Logged. + +**Requirement Reference:** REQ-SEC-SLM-GSE-1, REQ-SEC-SLM-GSE-2, REQ-SEC-SLM-GSE-3, REQ-SEC-SLM-GSE-4, REQ-SEC-SLM-GSE-5, REQ-SEC-SLM-GSE-6. + +**Requirement Description:** Logging of general security events. + +**Threat References:** T-ORAN-01, T-O-RAN-02, T-O-RAN-03, T-O-RAN-08, T-GEN-02, T-VM-C-01, T-VM-C-04, T-VM-C-06, T-IMG-01, T-IMG-04, T-VL-01, T-VL-02, T-xAPP-01, T-rAPP-03, T-HW-02. + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_General\_Security\_Events\_Logged + +**Purpose:** The purpose of the test is to verify the logging of general security events + +### Procedure and execution steps + +#### Preconditions + +A tester will have access to testing equipment that can communicate securely with the DUT and is able to perform security and administrative related operations. + +#### Execution steps + +NOTE 1: Execution steps not applicable to the DUT may be skipped. + +1. Login to the DUT via testing equipment with authorized credentials. +2. Execute the following operations on the DUT. + - 2.1. Enable security software such as firewalls, malware protection, data loss prevention or intrusion detection systems. + - 2.2. Disable security software such as firewalls, malware protection, data loss prevention or intrusion detection systems. + - 2.3. Log into DUT using an account with administrative privileges and perform a function that requires those privileges. + - 2.4. Make a change to the security configuration of the DUT. + - 2.5. View a certificate or key on the DUT. + - 2.6. Export a certificate or key from the DUT. + - 2.7. Renew a certificate or key on the DUT. + - 2.8. Import a certificate or key from the DUT. + - 2.9. Modify a certificate or key on the DUT. + - 2.10. Delete a certificate or key from the DUT. + - 2.11. Perform a cryptographic operation on the DUT that involves signatures, encryption, hashing, key generation or key destruction. + - 2.12. Submit a security patch to the DUT but do not apply it. + +#### Expected results + +All the security logs produced by O-RAN architecture elements contain log messages that document appropriately the actions taken in the execution steps. + +- For execution steps 2.1 and 2.2 the log message indicates that the security software has been enabled or disabled. +- For execution step 2.3 the log message indicates the use of administrative privileges. +- For execution step 2.4 the log message indicates that a change to the security configuration has occurred and the nature of the change. +- For executions 2.5 through 2.11 the log message is absent of any sensitive information related to the certificate or key. +- For execution 2.12 the log message indicates that a security patch was submitted but not applied. + +**Expected format of evidence:** Generated Log Files from DUT. + +## 8.4.9 Void + +--- + +# 9 Software security evaluation for O-RAN architecture elements + +## 9.1 Overview + +This clause contains a set of software security evaluations of an O-RAN architecture element, covering Software Lifecycle Management. + +## 9.2 Open-Source Software Component Analysis + +Void + +## 9.3 Binary Static Analysis + +Void + +## 9.4 Software Bill of Materials (SBOM) + +### 9.4.1 SBOM Signature + +**Requirement Name:** A digital signature is provided for the SBOM. + +**Requirement Reference:** SEC-CTL-SBOM-001, clause 6.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** SBOM is authenticity, integrity protected and provided in a standard format. + +**Threat References:** T-O-RAN-09 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test name:** TC\_SBOM\_Signature + +**Purpose:** To verify the SBOM is provided with a digital signature + +**Procedure and execution steps** + +**Preconditions** + +SBOM is provided. Tools to verify the digital signature are available. Solution Provider key or certificate is provided. + +**Execution steps** + +Ensure the SBOM is provided with a digital signature in the format as described below. Verify SBOM digital signature is valid using the software provider's public key or certificate. Depending on the format of the SBOM, there are various ways how to include and verify the digital signature of the SBOM. Below, the digital signature methods are detailed. + +SPDX + +YAML, RDF and tag data: The signature is in a separate file from the SPDX file. Digital signature format is CMS/PKCS#7/CAAdES. + +EXAMPLE: foo.spdx is accompanied by foo.spdx.sig containing its signature + +XML: XML Signature 2.0 + +JSON: JSON Web Signature (JWS), and JSON Signature Format (JSF). + +CycloneDX + +XML: XML Signature 2.0 + +JSON: JSON Web Signature (JWS), and JSON Signature Format (JSF). + +SWID + +XML: XML Signature 2.0 + +#### **Expected results** + +Digital signature of the SBOM is valid. + +**Expected format of evidence:** Report file, screenshot, or log file from tool used for verification of digital signature. + +## 9.4.2 SBOM Data Fields + +**Requirement Name:** Data fields are according to NTIA guidance [13] + +**Requirement Reference:** REQ-SBOM-002, REQ-SBOM-011, clause 6.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** A minimum set of data fields are included in the SBOM and it is in an standard format. + +**Threat References:** T-O-RAN-09 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_SBOM\_Data\_Fields + +**Purpose:** To verify the minimum set of data fields are included in the SBOM + +#### **Procedure and execution steps** + +##### **Preconditions** + +SBOM file is provided. Tools to verify the data fields are available. + +##### **Execution steps** + +Run the SBOM check tool and verify that there is minimum set of data fields present in SBOM depending on the SBOM format used. + +**Table 9-1: Minimum set of data fields for SPDX [12]** + +| NTIA field | NTIA description | SPDX 2.2.1 field | +|--------------------------|-----------------------------------------------------------------------------------------------------------|----------------------------------| +| Supplier Name | The name of an entity that creates, defines, and identifies components | PackageSupplier | +| Component Name | Designation assigned to a unit of software defined by the original supplier | PackageName | +| Version of the Component | Identifier used by the supplier to specify a change in software from a previously identified version | PackageVersion | +| Other Unique Identifiers | Other identifiers that are used to identify a component, or serve as a look-up key for relevant databases | SPDXID (Package SPDX Identifier) | +| Dependency Relationship | Characterizing the relationship that an upstream component X is included in software Y | Relationship: CONTAINS | +| Author of SBOM Data | The name of the entity that creates the SBOM data for this component | Creator | +| Timestamp | Record of the date and time of the SBOM data assembly | Created | + +**Table 9-2: Minimum set of data fields for CycloneDX [13]** + +| NTIA field | NTIA description | CycloneDX field | +|--------------------------|-----------------------------------------------------------------------------------------------------------|--------------------------------------------------------| +| Supplier Name | The name of an entity that creates, defines, and identifies components | publisher | +| Component Name | Designation assigned to a unit of software defined by the original supplier | name | +| Version of the Component | Identifier used by the supplier to specify a change in software from a previously identified version | version | +| Other Unique Identifiers | Other identifiers that are used to identify a component, or serve as a look-up key for relevant databases | bom/serialNumber and component/bom-ref | +| Dependency Relationship | Characterizing the relationship that an upstream component X is included in software Y | (Nested assembly/subassembly and/or dependency graphs) | +| Author of SBOM Data | The name of the entity that creates the SBOM data for this component | bom-descriptor:metadata/manufacture/contact | +| Timestamp | Record of the date and time of the SBOM data assembly | timestamp | + +**Table 9-3: Minimum set of data fields for SWID [13]** + +| NTIA field | NTIA description | SWID tag | +|--------------------------|-----------------------------------------------------------------------------------------------------------|---------------------------------------------------| +| Supplier Name | The name of an entity that creates, defines, and identifies components | @role (softwareCreator/publisher), @name | +| Component Name | Designation assigned to a unit of software defined by the original supplier | @name | +| Version of the Component | Identifier used by the supplier to specify a change in software from a previously identified version | @version | +| Other Unique Identifiers | Other identifiers that are used to identify a component, or serve as a look-up key for relevant databases | @tagID | +| Dependency Relationship | Characterizing the relationship that an upstream component X is included in software Y | @rel, @href | +| Author of SBOM Data | The name of the entity that creates the SBOM data for this component | @role (tagCreator), @name | +| Timestamp | Record of the date and time of the SBOM data assembly | - | + +This test is part of the O-RAN software producer's Software Development Lifecycle (SDLC). + +#### Expected results + +Minimum set of data fields are present. + +**Expected format of evidence:** Report file, screenshot, or log file from SBOM check tool. + +### 9.4.3 SBOM Format + +**Requirement Name:** SBOM is provided in one of the accepted formats: SPDX, CycloneDX, or SWID. + +**Requirement Reference:** REQ-SBOM-011, clause 6.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** SBOM is provided in a standard format. + +**Threat References:** T-O-RAN-09 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_SBOM\_Format + +**Purpose:** To verify that the SBOM is provided in one of standard formats. + +#### Procedure and execution steps + +##### Preconditions + +SBOM is provided. Tools to verify the SBOM are available. + +##### Execution steps + +Run the SBOM check tool to verify the SBOM format. + +**Expected results** + +SBOM format is SPDX, CycloneDX, or SWID. + +**Expected format of evidence:** Report file. + +## 9.4.4 SBOM Depth + +**Requirement Name:** SBOM Depth is in the required level. + +**Requirement Reference:** REQ-SBOM-004, clause 6.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** The SBOM Depth is the required for the different types of software. + +**Threat References:** T-O-RAN-09 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_SBOM\_Depth + +**Purpose:** To verify that the SBOM depth is provided to the level specified. + +**Procedure and execution steps****Preconditions** + +SBOM is provided. Tools to verify the SBOM are available. + +**Execution steps** + +Run the SBOM check tool to verify the SBOM depth provided. + +At a minimum, all top-level dependencies are listed. + +**Expected results** + +SBOM depth is as specified in the requirements: + +- top-level for every O-RAN software delivery + +**Expected format of evidence:** Report file, log file from SBOM check tool. + +## 9.4.5 Void + +## 9.4.6 SBOM Version Verification + +**Requirement Name:** The version in the SBOM is accurately and matches the actual O-RAN software package version. + +**Requirement Reference:** REQ-SBOM-002, clause 6.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Version of the software component included in the SBOM is matching the actual software component version. + +**Threat References:** T-O-RAN-08, T-O-RAN-09 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_SBOM\_VERSION\_VERIFICATION + +**Purpose:** The purpose of this test is to ensure the SBOM reflects the current version of software package. + +**Procedure and execution steps** + +**Preconditions** + +SBOM is provided. Tools to verify the SBOM are available. Access to version information regarding O-RAN software package. + +**Execution steps:** + +1. For each software component in the package, compare the version listed in the SBOM with the actual software component version. +2. Ensure that the SBOM's version matches the component's version. +3. Document any discrepancies. + +**Expected Results:** + +The version specified in the SBOM aligns with the actual version of the software component. + +**Expected format of evidence:** + +A report detailing: + +- name of the software package component(s), SBOM indicated version, actual version, notes on any discrepancies or issues found. + +## 9.4.7 Void + +## 9.4.8 SBOM Presence + +**Requirement Name:** SBOM provided with all O-RAN Software. + +**Requirement Reference:** REQ-SBOM-001, clause 6.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** For every O-RAN software delivery, an SBOM is available. + +**Threat References:** T-O-RAN-09 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_SBOM\_Presence + +**Purpose:** The purpose of this test is to ensure that for every O-RAN software delivery an SBOM is available. This is applicable to all software components within the O-RAN system. + +**Procedure and execution steps** + +**Preconditions** + +- SBOM is provided. Tools to verify the SBOM are available. + +**Execution steps** + +1. List O-RAN software delivery. +2. Look for associated files or documentation indicating the presence of an SBOM. +3. Validate the SBOM's content to ensure it's not just a placeholder. + +4. Document any software delivery that lacks a genuine SBOM. + +**Expected Results** + +Every O-RAN software delivery has a genuine SBOM associated with it. + +**Expected Format of Evidence:** + +- A report detailing: + - names of the software package components; + - status of its SBOM (Present/Absent). + - notes on any discrepancies or issues found. + +### 9.4.9 SBOM Vulnerabilities Field + +**Requirement Name:** Vulnerabilities field omission in SBOMs. + +**Requirement Reference:** REQ-SBOM-003, clause 6.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Vulnerabilities are not included as an additional data field because it would represent a static view from a specific point in time, while vulnerabilities are constantly evolving. Therefore, the vulnerabilities field in SBOM for O-RAN software cannot be relied upon to determine the SBOM vulnerabilities by the Service provider. Service providers need to perform their own vulnerability assessment, at least at the moment of the SBOM release. + +**Threat References:** T-O-RAN-09 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud **Test Name:** TC\_SBOM\_Vulnerabilities\_Fields + +**Purpose:** Verify that vulnerabilities fields is not included as an additional field to the SBOM. + +**Procedure and execution steps****Preconditions** + +SBOM is provided. Tools to verify the SBOM are available. + +**Execution steps** + +Verify that no vulnerabilities fields exist within the SBOM. + +**Expected Results** + +There are no vulnerabilities field(s) present in the SBOM. + +**Expected Format of Evidence:** screenshot(s) + +## 9.4.10 Void + +# 9.5 Software Image Signing and Verification + +## 9.5.1 Void + +## 9.5.2 Software Signature Verification + +**Requirement Name:** Any software image(s) of O-RAN architecture element(s) and/or app(s) is verified for its signature(s) by the Service provider for onboarding and/or deployment (instantiation process). + +**Requirement Reference:** SEC-CTL-ALM-PKG-1, SEC-CTL-ALM-PKG-1B, SEC-CTL-ALM-PKG-3, clause 5.3.2.1.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Application package is signed and verified for integrity and authenticity protection. + +**Threat References:** T-IMG-01, T-VM-C-02, T-Near-RT-01, T-Near-RT-02, T-xAPP-02 + +**DUT/s:** SMO, Non-RT RIC and rApps, Near-RT RIC and xApps, O-CU-CP, O-CU-UP, O-DU, O-RU, O-Cloud + +**Test Name:** TC\_SW\_Img\_Pkg\_Verification + +**Purpose:** Ensure signatures on O-RAN software image or application package and package artifacts are verified during onboarding and instantiation. + +### Procedure and execution steps + +#### Preconditions + +Digitally signed software image or Application package with shared necessary digital certificates or public key is validated. + +EXAMPLE: Root CA certificate, any intermediate or RA certificates. + +#### Execution steps + +The signature of the software image or Application package is verified either manually or using a software signing service. The software used to verify the signature(s) could be provided by software producer or internally published by the Service Provider. + +The Solution Provider signature of the ORAN software image(s) or application package is verified during onboarding. + +For image or Application package artifact instantiation, Service Provider signature of the software image or Application package verification is executed first, if applicable. Subsequently, Solution Provider signature is verified during instantiation. + +#### Expected results + +For signature verification during onboarding: + +The Solution Provider signature verification for software image or Application package is successful. + +For signature verification during instantiation: + +The Solution Provider signature verification for image or Application artifact during instantiation is successful. Additionally, if applicable, the Service Provider signature verification is also successful. + +**Expected Format of Evidence:** screenshot(s) + +--- + +## 10 ML security validation for O-RAN system + +### 10.1 Overview + +AI/ML technologies and models are adopted at the O-RAN system Non-RT RIC and Near-RT RIC to enable O-RAN use cases: traffic steering, massive MIMO optimization, radio resource allocation for UAV applications, position accuracy enhancement, beam management, and enhance CSI feedback. Other uses cases could be checked in document O-RAN Use Cases Detailed Specification [22]. + +### 10.2 ML Data Poisoning + +Void + +--- + +## 11 Security tests of O-RAN interfaces + +### 11.1 FH + +#### 11.1.1 Overview + +This clause contains security tests to validate the security protection mechanism of the O-RAN Open Fronthaul interface. + +#### 11.1.2 Open Fronthaul Point-to-Point LAN Segment + +##### 11.1.2.0 Introduction + +IEEE 802.1X-2020 Port-based Network Access Control [11] provides the means to control network access in point-to-point LAN segments within the Open Fronthaul network. Port-based network access control in the O-RAN Alliance Open Fronthaul comprises supplicant, authenticator, and authentication of server entities described in IEEE 802.1X-2020 [11]. + +The security test cases in this clause cover the validation of the authenticator and supplicant functionalities of the 802.1X, affecting to all the elements acting as an O-RAN Open Fronthaul network elements, including but not limited to, O-DU, O-RU, switches, FHM, FHGW, TNE and PRTC-T/GM as defined in clause 5.2.5.5 of Security Requirements and Controls Specifications [5]. + +##### 11.1.2.1 Authenticator Validation + +**Requirement Name:** Authenticator function validation + +**Requirement Reference:** SEC-CTL-OFHPLS-3, SEC-CTL-OFHPLS-4, SEC-CTL-OFHPLS-5, REQ-SEC-OFHPLS-1, clause 5.2.5.5, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Requirements of Authenticator in the Open Fronthaul network and its interface to an Authentication Server + +**Threat References:** T-FRHAUL-02 + +**DUT/s:** O-DU + +**Test Name:** TC\_Authenticator\_Validation + +**Purpose:** To verify and validate the authenticator requirements of the network component to serve the request from supplicant(s) using EAP TLS authentication per 802.1X-2020 [11]. + +### Procedure and execution steps + +#### Preconditions + +DUT supports authenticator role of the 802.1X for port-based network access control. + +IP enabled network interface of DUT reachable to the authentication server and 802.1X enabled for its Open Fronthaul interface. + +Set up an authentication server with root, server and client certificates, and the start the authentication server. + +EXAMPLE: RADIUS1 server (e.g. free radius on Linux) can be a possible authentication server. + +#### Execution steps + +Run the 802.1X test tool emulating the request(s) from the supplicant(s) towards the DUT, which is the authenticator and ensure the 802.1X authentication process runs to completion. + +The following test scenarios are executed: + +**Table 11-1: Scenarios to be executed** + +| Scenario ID | Configuration | +|-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Test tool (as supplicant) setting for 802.1X with EAPoL, correct Identity (Certificate DN) and Client Certificate (provisioned on the Radius server) | +| 2 | Test tool (as supplicant) setting for 802.1X with EAPoL, correct Identity (Certificate DN) and incorrect Client Certificate (not provisioned on the Radius server) | +| 3 | Test tool (as supplicant) setting for 802.1X with EAPoL and incorrect Identity (Certificate DN) | +| 4 | Test tool (as supplicant) setting for 802.1X with EAP non-TLS authentication | + +#### Expected results + +DUT successfully completes the procedure for the 802.1X Authentication validation (being granted or denied), for each test scenario: + +1 Because Radius support is required over interface between an authenticator and authentication server in the security requirement specification, only Radius authentication server is called for in this security test environment setup. Diameter based authentication server could be used as an alternative. + +**Table 11-2: Expected results** + +| Scenario ID | Expected result | Reason | +|-------------|----------------------------|--------------------------------------------------------------| +| 1 | Connection established | Authentication successfully | +| 2 | Connection not established | Fail Authentication because the certificate is wrong | +| 3 | Connection not established | Fail Authentication because the Identity is wrong | +| 4 | Connection not established | Fail Authentication because the authentication type is wrong | + +**Expected format of evidence:** log files and/or traffic captures. + +### 11.1.2.2 Supplicant Validation + +**Requirement Name:** Supplicant function validation + +**Requirement Reference:** SEC-CTL-OFHPLS-2, SEC-CTL-OFHPLS-5, REQ-SEC-OFHPLS-1, clause 5.2.5.5, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Requirements of Supplicant in the Open Fronthaul network + +**Threat References:** T-FRHAUL-02 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_Supplicant\_Validation + +**Purpose:** To verify the supplicant requirement of the network component for port connection request using EAP TLS authentication per 802.1X-2020 [11]. + +#### Procedure and execution steps + +##### Preconditions + +DUT supports supplicant role of the 802.1X for port-based network access control. + +Set up an authentication server with root, server and client certificates, and start the authentication server. + +EXAMPLE: RADIUS22 server (e.g. free radius on Linux) can be a possible authentication server. + +Set up the 802.1X test tool host/device as the authenticator with EAP TLS authentication for 802.1X protocol and configure the preset authentication server. + +##### Execution steps + +Start the test run as an emulated authenticator waiting for the supplicant request. + +Configure and enable the DUT to start the port connection request as a supplicant towards the 802.1X test tool, which is the authenticator and verify the 802.1X authentication process runs to completion. + +The following test scenarios are executed: + +22Because Radius support is required over interface between an authenticator and authentication server in the security requirement specification, only Radius authentication server is called for in this security test environment setup. Diameter based authentication server could be used as an alternative. + +**Table 11-3: Scenarios to be executed** + +| Scenario ID | Configuration | +|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | DUT (as supplicant) setting for 802.1X with EAPoL, correct Identity (Certificate DN) and Client Certificate (provisioned on the Radius server) | +| 2 | DUT (as supplicant) setting for 802.1X with EAPoL, correct Identity (Certificate DN) and incorrect Client Certificate (un-provisioned on the Radius server) | +| 3 | DUT (as supplicant) setting for 802.1X with EAPoL and incorrect Identity (Certificate DN) | +| 4 | DUT (as supplicant) setting for 802.1X with EAP non-TLS authentication (optional) | + +### Expected results + +DUT successfully completes the procedure for the supplicant validation (being granted or denied), for each test scenario: + +**Table 11-4: Expected results** + +| Scenario ID | Expected result | Reason | +|-------------|----------------------------|--------------------------------------------------------------| +| 1 | Connection established | Authentication successfully | +| 2 | Connection not established | Fail Authentication because the certificate is wrong | +| 3 | Connection not established | Fail Authentication because the Identity is wrong | +| 4 | Connection not established | Fail Authentication because the authentication type is wrong | + +**Expected format of evidence:** log files and/or traffic captures. + +## 11.1.3 M-Plane + +### 11.1.3.1 SSH-based M-Plane authentication, authorization and access control protection + +#### 11.1.3.1.0 Introduction + +The test cases outlined in this clause verify M-Plane authenticity, authorization, and access control protection over the FH interface using SSH. + +#### 11.1.3.1.1 Secure Password-Based Authentication and Authorization in FH\_MPLANE Using SSH + +**Requirement Name:** M-Plane authenticity protection over FH interface using SSH + +**Requirement Reference:** clause 5.4 in O-RAN WG4 Management Plane Specification [21] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05, T-FRHAUL-01, T-FRHAUL-02, T-MPLANE-01 + +**DUT/s:** O-RU + +**Test Name:** TC\_FH\_MPLANE\_SSH-PASSWORD-BASED\_AUTHENTICATION\_AUTHORIZATION + +**Purpose:** The purpose of this test is to verify the SSH password-based authentication and authorization mechanisms on the front-haul (FH) of the O-DU by the O-RU. + +### Procedure and execution steps + +#### Preconditions + +1. The O-RU is properly configured and operational. +2. Test equipment (potentially an O-DU or a dedicated SSH client simulator) is configured to establish SSH connections to the O-RU +3. NACM with NETCONF is enabled and configured for authorization on the FH interface. +4. SSH is properly implemented and configured as defined in [2] clause 4.1. + +#### Execution steps + +1. Execute the test on the SSH protocol as defined in clause 6.2. +2. Positive Case: Successful SSH password-based authentication and authorization. + - Test the successful SSH password-based authentication and authorization of the test equipment by the O-RU. + - a) Establish an SSH connection from the test equipment (acting as SSH client) to the O-RU (acting as SSH server) using the SSH password. + +EXAMPLE: "Command: ssh @" + +- b) Verify that the O-RU successfully authenticates the test equipment using the SSH password. + +EXAMPLE: "Command: **show ssh sessions**" + +- c) Validate that the test equipment is authorized to perform the requested operations on the FH interface after successful authentication. This operation should be within the scope of permitted actions for the authenticated entity. + +EXAMPLE of operations: "start up" installation, software management, configuration management, performance management, fault management and file management towards the O-RU + +- Monitor the responses from the O-RU to these operations. + - Record whether each operation was successfully executed, partially executed, or rejected. + - Verify the O-RU logs to confirm that the operations were authorized. +3. Negative Case: Failed SSH password-based authentication. + - Test the handling of failed SSH password-based authentication attempts of the test equipment by the O-RU in different scenarios. + - a) Attempt with incorrect password + - Attempt to establish an SSH connection from the test equipment to the O-RU using an incorrect password. + +EXAMPLE: Command: **ssh @**", using an incorrect password + +- Verify that the O-RU rejects the SSH connection due to the authentication failure. +- b) Attempt with non-existent username + +- Attempt to establish an SSH connection using a username that does not exist in the O-RU's user database. + +EXAMPLE: Command: ssh @ + +- Verify that the O-RU rejects the SSH connection, confirming that authentication does not proceed with non-existent usernames. + +### Expected Results + +For step 1): Expected results in clause 6.2 + +For step 2): + +- The SSH connection is successfully established using the SSH password. +- The O-RU validates the test equipment's SSH password for authentication. +- The O-RU grants the necessary authorization for the requested operations. + +For step 3): + +- The SSH connection attempt fails due to the incorrect password. +- The O-RU identifies the authentication failure and denies access. +- The SSH connection attempt fails due to the invalid username. +- The O-RU identifies the authentication failure and prevents access. + +### Expected format of evidence + +For step 1): Logs and screenshots showing adherence to SSH protocol specifications as defined in [2] clause 4.1. + +For step 2): Logs showing successful SSH authentication and authorization events. + +For step 3): Logs or error messages indicating failed SSH password-based authentication attempts for both incorrect password and invalid username scenarios. + +## 11.1.3.1.2 FH M-Plane SSH-certificate-based authentication authorization + +**Requirement Name:** M-Plane authenticity protection over FH interface using SSH + +**Requirement Reference:** Clause 5.4 in O-RAN WG4 Management Plane Specification [21] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05, T-FRHAUL-01, T-FRHAUL-02, T-MPLANE-01 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_FH\_MPLANE\_SSH-CERTIFICATE-BASED\_AUTHENTICATION\_AUTHORIZATION + +**Purpose:** The purpose of this test is to verify the SSH-certificate-based authentication and authorization mechanisms on the front-haul (FH) interface between O-RU and O-DU, using test equipment as needed to simulate either party. + +### Procedure and execution steps + +NOTE: Test equipment may simulate the role of O-DU or O-RU for the purpose of this test. + +### Preconditions + +1. The O-RU and O-DU devices are properly configured and operational. +2. Test equipment capable of simulating SSH client/server functionality is prepared to represent either the O-DU or O-RU as required. + +3. SSH keys and certificates are generated and installed on both the O-RU and O-DU devices. +4. NACM with NETCONF is enabled and configured for authorization on the FH interface. +5. SSH is properly implemented and configured as defined in [2] clause 4.1. + +### Execution steps + +Execute the test on the SSH protocol as defined in clause 6.2. + +Part A: Authentication and authorization of O-DU by O-RU (or test equipment simulating O-DU) + +- Positive Case: Successful SSH-certificate-based authentication and authorization. + - Establish an SSH connection from the O-RU to the O-DU using the SSH key and certificate. + - Verify that the O-RU successfully authenticates the O-DU using the SSH certificate. + +EXAMPLE: "Command: **show ssh sessions**" + +- Validate that the O-DU is authorized to perform the requested operations on the FH interface. + - Perform an operation on the FH interface that requires authorization. This operation should be within the scope of permitted actions for the authenticated O-DU. + +EXAMPLE of operations: "start up" installation, software management, configuration management, performance management, fault management and file management towards the O-RU + +- Monitor the responses from the O-RU to these operations. +- Record whether each operation was successfully executed, partially executed, or rejected. +- Verify the O-RU logs to confirm that the operations were authorized. +- Negative Case: Failed SSH-certificate-based authentication. + - Test the handling of failed SSH-certificate-based authentication attempts by the O-RU in different scenarios. + - Attempt with invalid key or certificate + - Attempt to establish an SSH connection using an incorrect or invalid SSH key or certificate. + +EXAMPLE: "Command: **ssh -i -o CertificateFile= @**" + +- Verify that the O-RU rejects the SSH connection due to the authentication failure. +- Attempt with invalid username + - Attempt to establish an SSH connection using a valid SSH key and certificate, but with a username that does not exist in the O-RU's system. + +EXAMPLE: "Command: **ssh -i -o CertificateFile= @**" + +- Verify that the O-RU rejects the SSH connection, confirming that the system does not authenticate usernames that are not registered or recognized. + +Part B: Authentication of O-RU by O-DU (or test equipment simulating O-RU) + +- Positive Case: Successful SSH-certificate-based authentication: + - Establish an SSH connection using the SSH key and certificate. + +- Verify that the O-DU successfully authenticates the O-RU using the SSH certificate. + +EXAMPLE: "Command: **show ssh sessions**" + +- Negative Case: Failed SSH-certificate-based authentication. + - Test the handling of failed SSH-certificate-based authentication attempts by the O-DU in different scenarios. + - Attempt with invalid key or certificate + - Attempt to establish an SSH connection using an incorrect or invalid SSH key or certificate. + +EXAMPLE: "Command: **ssh -i -o CertificateFile= @**" + +- Verify that the O-RU rejects the SSH connection due to the authentication failure. + - Attempt with invalid username + - Attempt to establish an SSH connection using a valid SSH key and certificate, but with a username that does not exist in the O-RU's system. + +EXAMPLE: "Command: **ssh -i -o CertificateFile= @**" + +- Verify that the O-DU rejects the SSH connection, confirming that the system does not authenticate usernames that are not registered or recognized. + +## Expected Results + +For step 1): Expected results in clause 6.2 + +For Parts A and B – Positive Case: + +- The SSH connection is successfully established using the correct SSH key and certificate. +- The DUT (O-RU or O-DU) validates the test equipment's SSH certificate for authentication. +- The O-RU grants the necessary authorization to the O-DU for the requested operations. +- The SSH connection attempt fails due to the incorrect or invalid SSH key or certificate. +- The DUT identifies the authentication failure and denies access accordingly. + +## Expected format of evidence + +For step 1): Logs and screenshots showing adherence to SSH protocol specifications as defined in [2] clause 4.1. + +For Parts A and B – Positive Case: Logs showing successful SSH authentication and authorization events. + +For Parts A and B – Negative Case: Logs or error messages indicating failed SSH-certificate-based authentication attempts for both invalid key/certificate and non-existent username scenarios. + +## 11.1.3.1.3 FH M-plane SSH Certificate-Based NACM Access Control + +**Requirement Name:** M-Plane access control protection over FH interface using SSH + +**Requirement Reference:** Clause 5.4 in O-RAN WG4 Management Plane Specification [21] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05, T-FRHAUL-01, T-FRHAUL-02, T-MPLANE-01 + +**DUT/s:** O-RU + +**Test Name:** TC\_FH\_MPLANE\_SSH-CERTIFICATE-BASED\_NACM\_ACCESS\_CONTROL + +**Purpose:** The purpose of this test is to verify the SSH-certificate-based NACM access control on the FH interface between O-RU and O-DU. + +### Procedure and execution steps + +#### Preconditions + +1. NACM with NETCONF is enabled and configured for SSH-certificate-based authorization on the FH interface. +2. Access control rules and permissions are defined and configured on both the O-RU and O-DU. +3. SSH is properly implemented and configured as defined in [2] clause 4.1. + +#### Execution steps + +1. Execute the test on the SSH protocol as defined in clause 6.2. +2. Positive Case: Successful SSH-certificate-based NACM authorization and access control. + - Test the successful enforcement of SSH-certificate-based NACM policies on the FH interface. + - a) Establish an SSH connection using the SSH key and certificate. + - b) Perform an operation on the FH interface with the O-RU using the SSH connection. + - c) Verify that the O-RU grants or denies access based on the SSH-certificate-based NACM rules and permissions. +3. Negative Case: Unauthorized access denial. + - Test the denial of access to unauthorized operations on the FH interface, including attempts with invalid credentials and invalid usernames. + - a) Attempt with invalid key or certificate + - Attempt to establish an SSH connection using an invalid key or certificate.. + - Confirm that the O-RU denies the SSH connection due to invalid credentials. + - b) Attempt with invalid username + - Attempt to establish an SSH connection using a valid SSH key and certificate but with an invalid username. + - Verify that the O-RU denies the SSH connection attempt due to the invalid username. + +#### Expected Results + +1. For step 1): Expected results in clause 6.2 +2. For step 2): + - The SSH connection is successfully established using the SSH key and certificate. + - The O-RU evaluates the SSH certificate-based NACM rules and permissions. + - The O-RU grants or denies access to the O-DU based on the SSH-certificate-based NACM configuration. +3. For step 3): + - Denial of SSH connection due to invalid key or certificate. + - Denial of SSH connection due to an invalid username. + +#### Expected format of evidence + +1. For step 1): Logs and screenshots showing adherence to SSH protocol specifications as defined in [2] clause 4.1. +2. For step 2), Logs or audit records indicating both successful access and access denial based on SSH-certificate-based NACM. +3. For step 3), Logs or error messages indicating access denial for unauthorized operations for both invalid credentials (key/certificate) and invalid usernames. + +### 11.1.3.2 SSH-based M-Plane integrity, confidentiality and replay protection + +The following test cases verify the M-Plane integrity, confidentiality, and replay protection over the FH interface using SSH. + +**Requirement Name:** M-Plane confidentiality, integrity and replay protection over FH M-Plane interface using SSH + +**Requirement Reference:** Clause 5.4 in O-RAN WG4 Management Plane Specifications [21] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05, T-FRHAUL-01, T-FRHAUL-02, T-MPLANE-01 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_FH\_MPLANE\_SSH\_CONFIDENTIALITY\_INTEGRITY\_REPLAY + +**Purpose:** To verify the enforcement of security policies over the FH M-Plane interface, ensuring that sensitive data remains protected through confidentiality, integrity, and replay protection using SSH. + +#### Procedure and execution steps + +##### Preconditions + +1. The O-RU and O-DU devices are properly configured and operational. +2. SSH keys and certificates are generated and installed on both the O-RU and O-DU devices. +3. SSH configuration is enabled to enforce confidentiality, integrity and replay protection on the FH M-plane interface. +4. SSH is properly implemented and configured as defined in [2] clause 4.1. + +##### Execution steps + +1. Confidentiality verification: + - Establish an SSH connection between the O-RU and O-DU using proper SSH keys and certificates. + - Transmit data over this connection. + - Capture and analyze the transmitted data to verify encryption, ensuring confidentiality. +2. Integrity protection verification: + - During the same SSH session, modify the transmitted packets midway. + - Attempt to deliver the modified packets to the DUT. + - Verify that the DUT detects and discards these packets. +3. Replay protection verification: + - Replay previously captured packets to the DUT within the same SSH session. + +- Confirm that the DUT detects and discards replayed packets. + +### Expected Results + +- Confidentiality: All sensitive data transmitted over the FH M-Plane interface is encrypted, with no data exposed in clear text. +- Integrity protection: The DUT detects and discards altered packets, ensuring the data has not been tampered with. +- Replay protection: The DUT detects and discards replayed packets, preventing replay attacks. + +### Expected format of evidence + +- Logs or screenshots showing SSH protocol adherence, as defined in the O-RAN Security Protocols Specifications [2] clause 4.1. +- Evidence of secure communication sessions established over the FH M-Plane interface, including details of encryption verification. +- Logs or screenshots showing the DUT's response to replayed and integrity-compromised packets, demonstrating the effectiveness of the security mechanisms in place. + +## 11.1.3.3 TLS-based M-Plane authentication, authorization and access control protection + +### 11.1.3.3.0 Introduction + +The test cases outlined in this clause verify M-Plane authenticity, authorization, and access control protection over the FH interface using TLS. + +#### 11.1.3.3.1 FH M-plane TLS Authentication + +**Requirement Name:** M-Plane authenticity protection over FH interface using TLS + +**Requirement Reference:** Clause 5.4 in O-RAN WG4 Management Plane Specification [21] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05, T-FRHAUL-01, T-FRHAUL-02, T-MPLANE-01 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_FH\_MPLANE\_TLS\_AUTHENTICATION + +**Purpose:** The purpose of this test is to verify the authentication mechanism between the O-RU and O-DU components over the TLS-based NACM with NETCONF on the FH interface for M-Plane. + +### Procedure and execution steps + +#### Preconditions + +1. For positive case: The O-RU and O-DU components are configured with valid TLS certificates for mutual authentication. +2. For negative case: The O-RU and O-DU components have misconfigured or invalid TLS certificates. +3. The NETCONF server is configured to enforce client authentication as defined in [2] clause 4.3. +4. TLS is properly implemented and configured as defined in [2] clause 4.2. + +#### Execution steps + +1. Execute the test on the TLS protocol as defined in clause 6.3. +2. Positive Case: Successful authentication. + +- Test the successful authentication of the O-RU and O-DU components over the TLS-based NACM with NETCONF on the FH interface. + - a) Initiates a TLS handshake. + - Use a command or tool that starts a TLS session + - b) Observe and validate that the O-RU checks the O-DU's certificate. + - Check O-RU logs or use network monitoring tools to confirm certificate verification and presentation. + - c) Confirm that the O-RU successfully verifies the O-DU's certificate, completing the mutual authentication. + - Review O-RU logs or use network monitoring tools to confirm the certificate verification. +3. Negative Case: Failed authentication. +- Test the failure of authentication over the TLS-based NACM with NETCONF on the FH interface due to invalid certificates. + - a) Initiate a TLS handshake from the O-DU with an invalid certificate. + - b) Check O-RU logs or network monitoring tools to observe the certificate verification attempt . + - c) Confirm that the TLS handshake fails and mutual authentication is not completed. + - Look for error messages or handshake failure indicators in the network traffic or logs. + +### Expected Results + +1. For step 1): Expected results in clause 6.3 +2. For step 2), The O-RU and O-DU components successfully authenticate each other over the TLS-based NACM with NETCONF on the FH interface. +3. For step 3), The O-RU and O-DU components fail to authenticate each other over the TLS-based NACM with NETCONF on the FH interface. + +### Expected format of evidence + +1. For step 1): Logs and screenshots showing adherence to TLS protocol specifications as defined in [2] clause 4.2. +2. For step 2), Logs or output indicating successful authentication. +3. For step 3), Logs or output indicating failed authentication. + +### 11.1.3.3.2 FH M-plane TLS Authorization + +**Requirement Name:** M-Plane authorization and access control protection over FH interface using TLS + +**Requirement Reference:** Clause 5.4 in O-RAN WG4 Management Plane Specification [21] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05, T-FRHAUL-01, T-FRHAUL-02, T-MPLANE-01 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_FH\_MPLANE\_TLS\_AUTHORIZATION + +**Purpose:** The purpose of this test is to verify the authorization mechanism for the O-RU and O-DU components over the TLS-based NACM with NETCONF on the FH interface. + +### Procedure and execution steps + +#### Preconditions + +1. The O-RU and O-DU components are successfully authenticated and have established a secure connection with the NETCONF server. +2. For positive case: The NACM rules and policies are properly configured on the NETCONF server to enforce authorization. +3. For negative case: The NACM rules and policies are misconfigured, or the O-RU is attempting an unauthorized operation. + +#### Execution steps + +1. Positive Case: Successful authorization. + - Test the successful authorization of the O-RU and O-DU components over the TLS-based NACM with NETCONF on the FH interface. + - a) The O-RU sends a NETCONF request to the O-DU component to perform an authorized operation. + - b) The NETCONF server evaluates the NACM rules and policies to determine if the O-RU is authorized to perform the requested operation. + - c) The O-DU component executes the authorized operation and sends a response to the O-RU. +2. Negative Case: Failed authorization. + - Test the failure of authorization for the O-RU and O-DU components over the TLS-based NACM with NETCONF on the FH interface. + - a) The O-RU sends a NETCONF request to the O-DU component to perform an unauthorized operation. + - b) The NETCONF server evaluates the NACM rules and policies and denies the unauthorized operation. + - c) The O-DU component rejects the unauthorized operation and sends an error response to the O-RU. + +#### Expected Results + +1. For step 1) Positive case: successful authorization: + - a) The O-RU's NETCONF request for an authorized operation is successfully received by the O-DU. + - b) The NETCONF server, after evaluating the NACM rules and policies, grants permission for the authorized operation. + - c) The O-DU successfully executes the authorized operation and sends a confirmation response to the O-RU. +2. For step 2) Negative case: failed authorization: + - a) The O-RU's NETCONF request for an unauthorized operation is received by the O-DU. + - b) The NETCONF server, upon evaluating the NACM rules and policies, denies the unauthorized operation. + - c) The O-DU does not execute the unauthorized operation and sends an error response to the O-RU, indicating the rejection. + +#### Expected format of evidence + +1. For step 1), Logs or output indicating successful authorization. +2. For step 2), Logs or output indicating failed authorization. + +#### 11.1.3.4 TLS-based M-Plane integrity, confidentiality and replay protection + +**Requirement Name:** M-Plane confidentiality, integrity, and replay protection over FH M-plane interface using TLS + +**Requirement Reference:** Clause 5.4 in O-RAN WG4 Management Plane Specifications [21] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05, T-FRHAUL-01, 02, T-MPLANE-01 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_FH\_MPLANE\_TLS\_CONFIDENTIALITY\_INTEGRITY\_REPLAY + +**Purpose:** To verify the enforcement of security policies over the FH M-Plane interface, ensuring that M-Plane data remains protected through confidentiality, integrity, and replay protection using TLS. + +#### Procedure and execution steps + +##### Preconditions + +1. O-RU, O-DU support TLS and be connected in simulated/real network environment. +2. The FH M-Plane interface is configured for testing. +3. TLS is properly implemented and configured as defined in [2] clause 4.2. + +##### Execution steps + +1. Confidentiality verification: + - Establish a secure communication session over the FH M-Plane interface. + - Capture the network traffic during the session. + - Analyse the captured traffic to verify that all data is encrypted, ensuring confidentiality. +2. Integrity protection verification: + - Capture protected packets after the TLS handshake. + - Modify the captured packets. + - Inject the modified packets to the DUT. + - Confirm that the DUT discards the injected packets, e.g., does not deliver it to the higher layer. +3. Replay protection verification: + - Capture protected packets after the TLS handshake. + - Replay the captured packets to the DUT. + - Confirm that the DUT discards the replayed packets. + +##### Expected results + +- Confidentiality: All sensitive data transmitted over the Y1 interface is encrypted, with no data exposed in clear text. + +- Integrity protection: The DUT detects and discards altered packets, ensuring data has not been tampered with. +- Replay protection: The DUT detects and discards replayed packets, preventing replay attacks. + +#### Expected format of evidence + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs or screenshots showing TLS protocol adherence, as defined in the O-RAN Security Protocols Specifications [2] clause 4.2. +- Evidence of secure communication sessions established over the Y1 interface, including details of encryption verification. +- Logs or screenshots showing the DUT's response to replayed and integrity-compromised packets, demonstrating the effectiveness of the security mechanisms in place. + +## 11.1.4 U-Plane + +### 11.1.4.1 U-Plane eCPRI Unexpected Input + +#### 11.1.4.1.0 Introduction + +The test cases in this clause focus on the O-DU's capability to recognize, handle, and respond appropriately to such anomalies in user plane packets over the eCPRI. This includes scenarios where packets are malformed or when they present unexpected payload sizes. + +#### 11.1.4.1.1 FH U-Plane Malformed Packet + +**Requirement Name:** Handling and rejection of malformed or invalid user plane packets + +**Requirement Reference:** Clause 5.2.5.2.1 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-FRHAUL-01, T-FRHAUL-02, T-UPLANE-01 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_FH\_U-PLANE\_MALFORMED\_PACKET + +**Purpose:** The purpose of this test is to verify the O-DU's ability to handle and reject malformed or invalid user plane packets. + +#### Procedure and execution steps + +##### Preconditions + +- A valid eCPRI connection between the O-RU and O-DU. + +##### Execution steps + +1. Generate a user plane packet with invalid or malformed data, such as incorrect headers, corrupted payload, or unsupported formats. +2. Transmit the malformed packet over the eCPRI. +3. Monitor the O-DU's response and behaviour. +4. Verify that the O-DU identifies and rejects the malformed packet. +5. Observe the impact on the O-DU, such as error messages, logging, or abnormal behaviour. + +#### Expected Results + +- The O-DU detects and rejects malformed or invalid user plane packets. +- It handles the rejection gracefully without affecting normal operation. +- Appropriate error messages or log entries are generated. + +**Expected Format of Evidence:** + +- Steps performed with detailed execution logs. +- Screenshots or logs indicating the detection and rejection of the malformed packet. + +#### 11.1.4.1.2 FH U-Plane Unexpected Payload Size + +**Requirement Name:** Handling and rejection of malformed or invalid user plane packets + +**Requirement Reference:** Clause 5.2.5.2.1 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-FRHAUL-01, T-FRHAUL-02, T-UPLANE-01 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_FH\_U-PLANE\_UNEXPECTED\_PAYLOAD\_SIZE + +**Purpose:** The purpose of this test is to verify the O-DU's ability to handle unexpected payload sizes in user plane packets. + +**Procedure and execution steps****Preconditions** + +- A valid eCPRI connection between the O-RU and O-DU. + +**Execution steps** + +1. Generate a user plane packet with an unexpected payload size, exceeding the normal or allowed range. +2. Transmit the packet with the unexpected payload size over the eCPRI. +3. Monitor the O-DU's response and behaviour. +4. Verify that the O-DU detects the unexpected payload size and takes appropriate action. +5. Observe the impact on the O-DU, such as error handling, packet drops, or performance degradation. + +**Expected Results** + +- The O-DU detects and handles unexpected payload sizes in user plane packets. +- It either rejects the packet or handles it with appropriate error handling mechanisms. +- The O-DU maintains acceptable performance levels despite the unexpected payload size. + +**Expected Format of Evidence:** + +- Steps performed with detailed execution logs. +- Screenshots or logs indicating the detection and handling of the unexpected payload size. + +## 11.1.5 S-Plane + +### 11.1.5.1 DoS Attack against a Master Clock + +#### 11.1.5.1.0 Introduction + +The tests outlined in this clause evaluate the system's defense capabilities against DoS attacks targeting the master clock, especially in different LLS configurations. + +#### 11.1.5.1.1 DOS Master Clock LLS C1 C2 C3 + +**Requirement Name:** S-Plane DoS protection + +**Requirement Reference:** REQ-SEC-DOS-1, clause 5.3.5, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-SPLANE-01 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_DOS\_MASTER\_CLOCK\_LLS\_C1\_C2\_C3 + +**Purpose:** The purpose of this test is to verify the protection of the S-plane against a denial of service (DoS) attack targeting the master clock in LLS-C1, LLS-C2, LLS-C3 configurations. + +#### Procedure and execution steps + +##### Preconditions + +1. O-DU and O-RU are properly configured and connected. +2. For LLS-C1: The master clock functionality is enabled on the O-DU. O-DU is acting as a master and directly synchronizes O-RU. +3. For LLS-C2: One or more Ethernet switches are allowed in the fronthaul network. O-DU acting as master to distribute network timing toward O-RU. +4. For LLS-C3: One or more PRTC/T-GM are implemented in the fronthaul network to distribute network timing toward O-DU and O-RU. +5. A network monitoring tool is set up to capture and analyse network traffic. + +##### Execution steps + +1. Start monitoring the network traffic between the O-DU and O-RU. +2. Simulate a DoS attack by sending an excessive number of time protocol packets to the master clock using a testing tool. + - Simulate DoS attack for LLS-C1 + - Use a command-line tool like **ptp4l** or **pgrptp** with appropriate options to flood the Master clock's IP address or hostname with an excessive number of time protocol packets. + - Simulate DoS attack for LLS-C2 + - Use a custom script or tool that supports PTP communication to generate and send a large volume of time protocol packets targeting the IP address or hostname of the Master clock. + +- Simulate DoS attack for LLS-C3 + - Use a custom script or tool that supports PTP communication to generate and send a large volume of time protocol packets targeting the PRTC/T-GM in the LLS-C3 configuration. +- 3. Verify the functionality of the master clock and the synchronization status between the O-DU and O-RU during the attack. +- 4. Observe the impact on the accuracy and availability of the master clock. +- 5. Verify the functionality of the slave clocks at the O-RUs and their synchronization status with the master clock during the attack. +- 6. Evaluate the impact on O-RUs relying on accurate timing information: + - Measure the timing accuracy at the O-RUs before initiating the DoS attack to establish a baseline. + - During the DoS attack, continuously monitor the timing accuracy at the O-RUs at regular intervals (e.g., every 10 seconds). + - Compare the timing accuracy measurements taken during the attack to the baseline measurements. + - Identify any deviations or discrepancies in timing accuracy that exceed acceptable thresholds. + - Document any observed impact on O-RU operations that rely on precise timing, such as frame alignment, data transmission synchronization, or other time-sensitive processes. + - After the DoS attack has concluded, continue monitoring the O-RUs to determine how quickly they recover and return to their baseline timing accuracy. + +### Expected Results + +1. The S-plane detects and mitigates the DoS attack against the master clock for each LLS configuration (C1, C2, C3). +2. The master clock continues to operate with minimal impact on accuracy and availability. +3. The synchronization status between the O-DU and O-RU remains stable. +4. The slave clocks maintain synchronization with their respective master clocks, although some minor degradation may be expected. +5. O-RUs relying on accurate timing information should continue to function, although some degradation may be observed during the attack. + +### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided for each LLS configuration (C1, C2, C3): + +1. Network traffic logs showing the excessive time protocol packets sent to the master clock during the attack in LLS-C1, through Ethernet switches in LLS-C2 and targeting PRTC/T-GM in LLS-C3. +2. Monitoring reports indicating the behaviour of the master clock and synchronization status between the O-DU and O-RU during the attack. +3. Analysis of the impact on the accuracy and availability of the master clock. +4. Evaluation of the synchronization status of the slave clocks during the attack. + +#### 11.1.5.1.2 DOS Master Clock LLS C4 + +**Requirement Name:** S-Plane DoS protection + +**Requirement Reference:** REQ-SEC-DOS-1, clause 5.3.5, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-SPLANE-01 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_DOS\_MASTER\_CLOCK\_LLS\_C4 + +**Purpose:** The purpose of this test is to verify the protection of the S-plane against a denial of service (DoS) attack targeting the local PRTC timing in an LLS-C4 configuration. + +### **Procedure and execution steps** + +#### **Preconditions** + +1. The O-RU is configured with a local PRTC timing that provides time synchronization. +2. Local PRTC timing is enabled that provides time synchronization to the O-RU (it could be embedded in the O-RU). +3. A network monitoring tool is set up to capture and analyse network traffic. + +#### **Execution steps** + +1. Start monitoring the network traffic between the O-RU and the fronthaul network. +2. Simulate a DoS attack by sending an excessive number of time protocol packets to the O-RU's local PRTC timing using a testing tool. +3. Monitor the behaviour of the local PRTC timing and the synchronization status between the O-RU and the fronthaul network during the attack. +4. Observe the impact on the accuracy and availability of the local PRTC timing. +5. Verify the functionality of the O-RU during the attack to ensure that it can still operate normally despite the DoS attack on the local PRTC timing. + +#### **Expected Results** + +1. The S-plane detects and mitigates the DoS attack against the local PRTC timing in the O-RU. +2. The local PRTC timing continues to operate with minimal impact on accuracy and availability. +3. The synchronization status between the O-RU and the fronthaul network should remain stable. +4. The O-RU should continue to function normally, even with the DoS attack targeting the local PRTC timing. + +#### **Expected Format of Evidence:** + +The following evidence, in one or more formats as applicable, should be provided: + +1. Network traffic logs showing the excessive time protocol packets sent to the local PRTC timing during the attack. +2. Monitoring reports indicating the behaviour of the local PRTC timing and synchronization status between the O-RU and the fronthaul network during the attack. +3. Analysis of the impact on the accuracy and availability of the local PRTC timing. + +## 11.1.5.2 Spoofing of Master Clocks in the S-Plane + +The tests presented in this clause focus on assessing the system's defenses against potential spoofing attacks on master clocks. Specifically, these tests examine scenarios where attackers may try to impersonate or manipulate the master clock's communications to disrupt accurate time synchronization. + +### 11.1.5.2.1 Impersonation Master Clock + +**Requirement Name:** Spoofing Prevention for Master Clocks in the S-Plane + +**Requirement Reference:** REQ-SEC-OFSP-2, clause 5.2.5.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-SPLANE-02, T-SPLANE-03 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_IMPERSONATION\_MASTER\_CLOCK + +**Purpose:** The purpose of this test is to verify the protection of the S-plane against an impersonation attack where an attacker sends fake ANNOUNCE messages to declare itself as the best clock (Grand Master). + +#### Procedure and execution steps + +##### Preconditions + +1. For LLS-C1: The master clock functionality is enabled on the O-DU. O-DU is acting as a master and directly synchronizes O-RU. +2. For LLS-C2: One or more Ethernet switches are allowed in the fronthaul network. O-DU acting as master to distribute network timing toward O-RU. +3. For LLS-C3: One or more PRTC/T-GM are implemented in the fronthaul network to distribute network timing toward O-DU and O-RU. +4. For LLS-C4: Local PRTC timing is enabled that provides time synchronization to the O-RU (it could be embedded in the O-RU). +5. The master clock functionality of the O-DU is enabled and functioning correctly (not applicable in the LLS-C4 configuration). +6. A network monitoring tool is set up to capture and analyse network traffic. + +##### Execution steps + +1. Start monitoring the network traffic between the O-DU and O-RU. +2. Simulate an impersonation attack by sending a fake ANNOUNCE message declaring a different clock as the best clock in the network to the O-DU using a testing tool. + - For LLS-C1, use a command-line tool like **ptp4l** or **pgrptp** with appropriate options to send fake ANNOUNCE messages to the IP address or hostname of the O-DU acting as the legitimate Master clock. + - For LLS-C2, use a PTP simulation tool like **pysimulatedptp** or **ptpd** to generate fake ANNOUNCE messages with the attacker's clock information, targeting the IP address or hostname of the O-DU acting as the legitimate Master clock. + +- For LLS-C3, use a custom script or tool that supports PTP communication to craft and send fake ANNOUNCE messages to the IP addresses or hostnames of the PRTC/T-GM devices within the fronthaul network. + - For LLS-C4, use a PTP simulation tool or a custom script that can craft and send PTP ANNOUNCE messages that impersonates a legitimate PRTC or Grand Master clock, declaring a different clock (controlled by the attacker) as the best clock, and target this message to the O-RU's IP address or hostname. +3. Verify the functionality of the O-DU and O-RU upon receiving the fake ANNOUNCE message. + 4. Observe the synchronization status between the O-DU and O-RU. + 5. Verify that the O-DU and O-RU reject the impersonated clock and maintain the synchronization based on the legitimate master clock. + +### Expected Results + +1. The S-plane detects and mitigates the impersonation attack by recognizing the fake ANNOUNCE message. +2. The O-DU and O-RU reject the impersonated clock and maintain synchronization with the legitimate master clock. +3. The synchronization status between the O-DU and O-RU remains stable and accurate. +4. The O-RU continues to receive accurate timing information from the legitimate master clock. + +### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided for each configuration (LLS-C1, LLS-C2, LLS-C3, LLS-C4): + +1. Network traffic logs showing the transmission of the fake ANNOUNCE message to the O-DU. This includes logs for direct transmission to the O-DU (LLS-C1), through Ethernet switches (LLS-C2), to PRTC/T-GM devices (LLS-C3), and to O-RU with local PRTC (LLS-C4). +2. Monitoring reports indicating the behaviour of the O-DU and O-RU upon receiving the fake ANNOUNCE message. +3. Analysis of the synchronization status between the O-DU and O-RU. +4. Verification that the O-DU and O-RU reject the impersonated clock and maintain synchronization with the legitimate master clock. + +#### 11.1.5.2.2 Rogue PTP Instance + +**Requirement Name:** Spoofing Prevention for Master Clocks in the S-Plane + +**Requirement Reference:** REQ-SEC-OFSP-2, clause 5.2.5.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-SPLANE-02, T-SPLANE-03 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_ROGUE\_PTP\_INSTANCE + +**Purpose:** The purpose of this test is to verify the protection of the S-plane against an attacker sending manipulated or malicious ANNOUNCE messages to declare itself as the best clock (Grand Master). + +## Procedure and execution steps + +### Preconditions + +1. For LLS-C1: The master clock functionality is enabled on the O-DU. O-DU is acting as a master and directly synchronizes O-RU. +2. For LLS-C2: One or more Ethernet switches are allowed in the fronthaul network. O-DU acting as master to distribute network timing toward O-RU. +3. For LLS-C3: One or more PRTC/T-GM are implemented in the fronthaul network to distribute network timing toward O-DU and O-RU. +4. For LLS-C4: Local PRTC timing is enabled that provides time synchronization to the O-RU (it could be embedded in the O-RU). +5. The O-DU and O-RU are synchronized and functioning correctly. +6. A network monitoring tool is set up to capture and analyse network traffic. + +### Execution steps + +1. Start monitoring the network traffic between the O-DU and O-RU. +2. Simulate an attack by injecting manipulated or malicious ANNOUNCE messages declaring the attacker as the best clock in the network by sending manipulated or malicious ANNOUNCE messages impersonating a Grand Master clock. + - For LLS-C1, use a command-line tool like **ptp4l** or **pgrptp** with appropriate options to send manipulated ANNOUNCE messages to the IP address or hostname of the O-DU acting as the legitimate Master clock. + - For LLS-C2, use a PTP simulation tool like **pysimulatedptp** or **ptpd** to generate manipulated ANNOUNCE messages with the attacker's clock information, targeting the IP address or hostname of the O-DU acting as the legitimate Master clock. + - For LLS-C3, use a custom script or tool that supports PTP communication to craft and send manipulated ANNOUNCE messages to the IP addresses or hostnames of the PRTC/T-GM devices within the fronthaul network. + - For LLS-C4, if the Master clock is embedded in the O-RU, simulate the attack by sending manipulated ANNOUNCE messages directly to the O-RU. +3. Verify the functionality of the O-DU and O-RU upon receiving the manipulated or malicious ANNOUNCE messages. +4. Observe the synchronization status between the O-DU and O-RU. +5. Verify that the O-DU and O-RU detect and reject the attacker's proposed grandmaster candidate. + +### Expected Results + +1. The S-plane detects and mitigates the attack by recognizing the manipulated or malicious ANNOUNCE messages. +2. The O-DU and O-RU reject the attacker's proposed grandmaster candidate and maintain synchronization based on the legitimate master clock. +3. The synchronization status between the O-DU and O-RU remains stable and accurate. +4. The O-RU continues to receive accurate timing information from the legitimate master clock. + +### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided for each configuration (LLS-C1, LLS-C2, LLS-C3, LLS-C4): + +1. Network traffic logs showing the transmission of the manipulated or malicious ANNOUNCE messages. These logs should demonstrate the attack simulation for LLS-C1 (O-DU as master), LLS-C2 (with Ethernet switches), LLS-C3 (with PRTC/T-GM), and LLS-C4 (local PRTC timing in O-RU). +2. Monitoring reports indicating the behaviour of the O-DU and O-RU upon receiving the manipulated or malicious ANNOUNCE messages. +3. Analysis of the synchronization status between the O-DU and O-RU. +4. Verification that the O-DU and O-RU reject the attacker's proposed grandmaster candidate and maintain synchronization with the legitimate master clock. + +### 11.1.5.3 Clock Accuracy Protection Against MITM Attacks + +This clause delves into tests specifically designed to gauge the system's robustness when facing MITM attacks targeting clock synchronization. Such MITM attacks could manifest as the selective interception and removal of crucial PTP timing packets or the deliberate introduction of delays to these packets. + +#### 11.1.5.3.1 Selective Interception and Removal of PTP Timing Packets + +**Requirement Name:** Clock Accuracy Protection Against MITM Attacks + +**Requirement Reference:** REQ-SEC-OFSP-3, clause 5.2.5.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-SPLANE-04, T-SPLANE-05 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_SELECTIVE\_INTERCEPTION\_REMOVAL\_PTP\_TIMING\_PACKETS + +**Purpose:** The purpose of this test is to verify the resilience of the S-plane against an attack where PTP timing packets are selectively intercepted and removed. + +#### Procedure and execution steps + +##### Preconditions + +1. For LLS-C1: The master clock functionality is enabled on the O-DU. O-DU is acting as a master and directly synchronizes O-RU. +2. For LLS-C2: One or more Ethernet switches are allowed in the fronthaul network. O-DU acting as master to distribute network timing toward O-RU. +3. For LLS-C3: One or more PRTC/T-GM are implemented in the fronthaul network to distribute network timing toward O-DU and O-RU. +4. For LLS-C4: Local PRTC timing is enabled that provides time synchronization to the O-RU (it could be embedded in the O-RU). +5. The network monitoring tool is set up to capture and analyse network traffic between the O-RU and O-DU. + +##### Execution steps + +1. Set up the test environment with the O-RAN O-RU, O-DU, and other relevant network components. + +2. Configure the network monitoring tool to capture PTP timing packets between the O-RU and O-DU. +3. Start the network monitoring tool to capture the initial state of PTP timing packets. +4. Simulate an attack by using a packet manipulation tool to selectively intercept and remove specific PTP timing packets. + - For LLS-C1, use a packet capture tool like Wireshark or tcpdump to capture PTP network traffic on the interface connected to the O-RU or O-DU. Modify the captured packets to selectively remove PTP timing packets using a packet editing tool like Scapy or custom scripts. + - For LLS-C2, use a network device or software with packet interception capabilities to intercept PTP timing packets between the O-RU and O-DU. Modify the intercepted packets to selectively remove PTP timing packets. + - For LLS-C3, use a network device or software capable of deep packet inspection (DPI) to intercept and analyse PTP timing packets. Modify the intercepted packets to selectively remove PTP timing packets. + - For LLS-C4, if the O-RU embeds the local PRTC timing, use a network device or software to intercept PTP timing packets between the O-RU and O-DU. Modify the intercepted packets to selectively remove PTP timing packets. +5. Verify the functionality of the O-RU and O-DU during the attack simulation. +6. Observe the synchronization status and the impact on timing accuracy between the O-RU and O-DU. +7. Capture and analyse the network traffic using the network monitoring tool during the attack simulation. + +NOTE: The network monitoring tool can be Wireshark or tcpdump, configured to capture packets on the interfaces between the O-RU, O-DU and to identify the intercepted and removed PTP timing packets. + +8. Stop the network monitoring tool to finalize the captured traffic. + +### Expected Results + +1. Detection of missing PTP timing packets: The S-plane is able to detect the absence of specific PTP timing packets that were selectively intercepted and removed. +2. Synchronization maintenance: Despite the missing PTP timing packets, the O-RU and O-DU still maintain synchronization. Any deviations from expected synchronization are minimal and within acceptable thresholds. +3. Corrective actions: Upon detecting the missing PTP timing packets, the O-RU and O-DU initiate predefined corrective actions to restore synchronization and mitigate the effects of the missing packets. +4. Network traffic analysis: The captured network traffic clearly shows the instances where specific PTP timing packets were intercepted and removed. +5. No system failures: The system (O-RU and O-DU) doesn't experience any catastrophic failures or shutdowns due to the missing PTP timing packets. + +### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided for each configuration (LLS-C1, LLS-C2, LLS-C3, LLS-C4): + +1. Recorded network traffic captured by the monitoring tool during the attack simulation showing selective interception and removal of PTP timing packets in LLS-C1 (O-DU as master), LLS-C2 (with Ethernet switches), LLS-C3 (with PRTC/T-GM), and LLS-C4 (local PRTC timing in O-RU). +2. Observations and analysis of the impact on synchronization and timing accuracy. + +3. Any issues or anomalies encountered during the attack simulation. + +### 11.1.5.3.2 Delay Attack on PTP Timing Packets + +**Requirement Name:** Clock Accuracy Protection Against MITM Attacks + +**Requirement Reference:** REQ-SEC-OFSP-3, clause 5.2.5.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-SPLANE-04, T-SPLANE-05 + +**DUT/s:** O-RU, O-DU + +**Test Name:** TC\_DELAY\_ATTACK\_PTP\_TIMING\_PACKETS + +**Purpose:** The purpose of this test is to verify the S-plane's resilience against a delay attack on PTP timing packets. + +#### Procedure and execution steps + +##### Preconditions + +1. For LLS-C1: The master clock functionality is enabled on the O-DU. O-DU is acting as a master and directly synchronizes O-RU. +2. For LLS-C2: One or more Ethernet switches are allowed in the fronthaul network. O-DU acting as master to distribute network timing toward O-RU. +3. For LLS-C3: One or more PRTC/T-GM are implemented in the fronthaul network to distribute network timing toward O-DU and O-RU. +4. For LLS-C4: Local PRTC timing is enabled that provides time synchronization to the O-RU (it could be embedded in the O-RU). +5. Time synchronization is established and operational within the network. + +##### Execution steps + +1. Start the network monitoring tool to capture the initial state of PTP timing packets. +2. Simulate an attack by introducing delays in PTP timing packets using a network emulation tool. + - For LLS-C1, use a network emulator tool like WANem or NIST Net to introduce artificial delays in PTP timing packets between the O-RU and O-DU. + - For LLS-C2 and LLS-C3, use a custom script or tool that supports packet manipulation and delay to introduce artificial delays in PTP timing packets between the O-RU and O-DU or between PRTC/T-GM devices. + - For LLS-C4, if the O-RU embeds the local PRTC timing, use a network emulator tool or custom script to introduce delays in PTP timing packets between the O-RU and O-DU. +3. Verify the functionality of the O-RU and O-DU during the delay attack on PTP timing packets. +4. Observe the synchronization status and timing accuracy within the LLS configuration. + +##### Expected Results + +1. The S-plane detects the delay attack on PTP timing packets and applies appropriate measures to mitigate the impact within all LLS configurations. + +2. The O-RU and O-DU detects the delayed PTP timing packets, compensate for the introduced delays, and maintain synchronization. + +#### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided for each configuration (LLS-C1, LLS-C2, LLS-C3, LLS-C4): + +1. Recorded network traffic captured by the monitoring tool during the attack. This includes logs showing the introduction of delays in PTP timing packets for LLS-C1 (O-DU as master), LLS-C2 (with Ethernet switches), LLS-C3 (with PRTC/T-GM), and LLS-C4 (local PRTC timing in O-RU). +2. Observations and analysis of the impact on synchronization and timing accuracy within each LLS configuration. +3. Any issues or anomalies encountered during the attack simulation. + +## 11.2 Y1 + +### 11.2.1 Y1 Authenticity + +**Requirement Name:** Y1 protection in terms of authenticity + +**Requirement Reference:** SEC-CTL-NEAR-RT-9, clause 5.1.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-Y1-01, T-Y1-02, T-Y1-03 + +**DUT/s:** Near-RT RIC, Y1 consumers + +**Test Name:** TC\_Y1\_AUTHENTICATION + +**Purpose:** The purpose of this test is to verify the authenticity of the Y1 interface, ensuring that only legitimate and mutually authenticated Near-RT RIC, Y1 consumers can participate in the communication over the Y1 interface. + +#### Procedure and execution steps + +##### Preconditions + +1. Near-RT RIC & Y1 Consumers support mTLS and be connected in a simulated/real network environment. +2. The test environment is set up with the Y1 interface configured. +3. The tester has access to the original data transported over the Y1 interface. +4. mTLS is properly implemented and configured as defined in [2] clause 4.2. + +##### Execution steps + +1. Execute the test on the mTLS protocol as defined in clause 6.3. +2. Valid Authentication Certificates (positive case): + - a. The tester sends a request to establish a connection with the Y1 interface using valid authentication certificates. + - b. The tester verifies the mutual certificate verification between Near-RT RIC and Y1 consumers. + - c. The tester captures and analyses the response received from the Y1 interface. + +3. Invalid Authentication Certificates (negative case): + - a. The tester sends a request to establish a connection with the Y1 interface with invalid certificates. + - b. The tester captures and analyses the response received from the Y1 interface. +4. No Authentication Certificates (Negative Case): + - a. The tester sends a request to establish a connection without any certificates. + - b. The tester captures and analyses the response from the Y1 interface. + +#### Expected results + +1. For 1. Expected results in clause 6.3 +2. For 2. ‘Valid Authentication Certificates’: The Y1 interface accepts the valid certificates and responds with a successful authentication message. The mutual certificate verification process is successful. +3. For 3. ‘Invalid Authentication Certificates’: The connection attempt is rejected, and an authentication failure message is received. The mutual certificate verification process fails due to the use of invalid certificates. +4. For 4. ‘No Authentication Certificates’: The connection attempt is rejected, and an authentication failure message is received. The mutual certificate verification process fails due to the absence of certificates. + +#### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs and screenshots showing adherence to mTLS protocol specifications as defined in [2] clause 4.2. +- Logs of authentication requests and responses on the Y1 interface +- Logs of the mutual certificate verification process. +- Screenshots or logs of error messages or unusual behaviours for both invalid and no certificate scenarios. + +## 11.2.2 Y1 confidentiality, integrity, and replay protection + +**Requirement Name:** Y1 protection in terms of confidentiality, integrity and replay + +**Requirement Reference:** SEC-CTL-NEAR-RT-11, clause 5.1.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-Y1-01, T-Y1-02, T-Y1-03 + +**DUT/s:** Near-RT RIC, Y1 consumers + +**Test Name:** TC\_Y1\_CONFIDENTIALITY\_INTEGRITY\_REPLAY + +**Purpose:** To verify the enforcement of security policies over the Y1 interface, ensuring that sensitive data remains protected through confidentiality, integrity, and replay protection. + +#### Procedure and execution steps + +##### Preconditions + +1. Near-RT RIC and Y1 consumers support TLS and connected within simulated or real network environments. +2. The Y1 interface is configured for testing. +3. TLS is properly implemented and configured as defined in [2] clause 4.2. + +##### Execution steps + +1. Confidentiality verification: + +- Establish a secure communication session over the Y1 interface. +- Capture the network traffic during the session. +- Analyse the captured traffic to verify that all data is encrypted, ensuring confidentiality. + +2. Integrity protection verification: + +- Capture protected packets after the TLS handshake. +- Modify the captured packets. +- Inject the modified packets to the DUT. +- Confirm that the DUT discards the injected packets, e.g., does not deliver it to the higher layer. + +3. Replay protection verification: + +- Capture protected packets after the TLS handshake. +- Replay the captured packets to the DUT. +- Confirm that the DUT discards the replayed packets. + +**Expected results** + +- Confidentiality: All sensitive data transmitted over the Y1 interface is encrypted, with no data exposed in clear text. +- Integrity protection: The DUT detects and discards altered packets, ensuring data has not been tampered with. +- Replay protection: The DUT detects and discards replayed packets, preventing replay attacks. + +**Expected Format of Evidence:** + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs or screenshots showing TLS protocol adherence, as defined in the O-RAN Security Protocols Specifications [2] clause 4.2. +- Evidence of secure communication sessions established over the Y1 interface, including details of encryption verification. +- Logs or screenshots showing the DUT's response to replayed and integrity-compromised packets, demonstrating the effectiveness of the security mechanisms in place. + +### 11.2.3 Y1 Authorization + +**Requirement Name:** Y1 protection in terms of mutual Authorization + +**Requirement Reference:** SEC-CTL-NEAR-RT-10, clause 5.1.2.3, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-Y1-01, T-Y1-02, T-Y1-03 + +**DUT/s:** Near-RT RIC and Y1 consumers + +**Test Name:** TC\_Y1\_AUTHORIZATION + +**Purpose:** The purpose of this test is to validate that the Y1 interface enforces an authorization mechanism to prevent unauthorized access. + +## Procedure and execution steps + +### Preconditions + +1. Near-RT RIC and Y1 consumers support OAuth 2.0 and are connected in simulated/real network environment. +2. The test environment is set up with Y1 interface configured. +3. The tester has access to the original data transported over the Y1 interface. +4. OAuth 2.0 is properly implemented and configured. + +### Execution steps + +1. Execute the test on the OAuth 2.0 protocol as defined in clause 6.6. +2. Valid access tokens (positive case): + - a. The tester sends a request to access protected resources using a valid access token. + - b. The tester captures and analyses the response from the Y1 interface. +3. Invalid access tokens (negative case): + - a. The tester sends a request to access protected resources using an invalid or incorrect access token. + - b. The tester captures and analyses the response from the Y1 interface. +4. No access tokens (negative case): + - a. The tester sends a request to access protected resources without providing any access token. + - b. The tester captures and analyses the response from the Y1 interface. + +### Expected Results + +- For 1. Expected results in clause 6.6 +- For 2. 'Valid access tokens': The Y1 interface accepts the valid access tokens and responds with a successful authorization message. +- For 3. 'Invalid access tokens': The access is rejected, and an access failure message is received. +- For 4. 'No access tokens': The access is rejected due to the absence of tokens, and an appropriate error or unauthorized access message is received. + +### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs of the request sent to access protected resources using valid access tokens. +- Screenshots or logs highlighting the successful authorization message. +- Logs of the request sent to access protected resources using invalid or incorrect access tokens. +- Screenshots or logs showing the rejection of the access and the access failure message. + +## 11.3 O1 + +### 11.3.1 O1 Authenticity + +**Requirement Name:** O1 protection in terms of authenticity + +**Requirement Reference:** SEC-CTL-O1-2, SEC-CTL-O1-5, clause 5.2.2.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-MPLANE-01, T-O-RAN-05 + +**DUT/s:** SMO, O-CU, O-DU, Near-RT RIC + +**Test Name:** TC\_O1\_AUTHENTICATION + +**Purpose:** The purpose of this test is to verify the authenticity of the O1 interface, ensuring that only legitimate and authenticated O-RAN NFs can participate in the communication over the O1 interface. + +**Procedure and execution steps****Preconditions** + +- SMO, O-CU, O-DU, Near-RT RIC support mTLS and be connected in simulated/real network environment. +- The test environment is set up with O1 interface configured. +- The tester has access to the original data transported over the O1 interface. +- mTLS is properly implemented and configured as defined in [2] clause 4.2. + +**Execution steps** + +1. Execute the test on the mTLS protocol as defined in clause 6.3. +2. Valid Authentication Certificates (positive case): + - a. The tester sends a request to establish a connection with the O1 interface using valid authentication certificates. + - b. The tester verifies the mutual certificate verification between the ORAN NFs + - c. The tester captures and analyses the response received from the O1 interface. +3. Invalid Authentication Certificates (negative case): + - a. The tester sends a request to establish a connection with the O1 interface with invalid certificates. + - b. The tester captures and analyses the response received from the O1 interface. +4. No Authentication Certificates (Negative Case): + - a. The tester sends a request to establish a connection without any certificates. + - b. The tester captures and analyses the response from the O1 interface. + +**Expected results** + +1. For 1. Expected results in clause 6.3 +2. For 2. 'Valid Authentication Certificates': The O1 interface accepts the valid certificates and responds with a successful authentication message. The mutual certificate verification process is successful. +3. For 3. 'Invalid Authentication Certificates': The connection attempt is rejected, and an authentication failure message is received. The mutual certificate verification process fails due to the use of invalid certificates. +4. For 4. 'No Authentication Certificates': The connection attempt is rejected, and an authentication failure message is received. The mutual certificate verification process fails due to the absence of certificates. + +**Expected Format of Evidence:** + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs and screenshots showing adherence to mTLS protocol specifications as defined in [2] clause 4.2. + +- Logs of authentication requests sent to the O1 interface. +- Logs of the mutual certificate verification process. +- Screenshots or logs of error messages or unusual behaviours for both invalid and no certificate scenarios. + +## 11.3.2 O1 confidentiality, integrity and replay protection + +**Requirement Name:** O1 protection in terms of confidentiality, integrity and replay + +**Requirement Reference:** SEC-CTL-O1-1, SEC-CTL-O1-4, clause 5.2.2.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-MPLANE-01, T-O-RAN-05 + +**DUT/s:** SMO, O-CU, O-DU, Near-RT RIC + +**Test Name:** TC\_O1\_CONFIDENTIALITY\_INTEGRITY\_REPLAY + +**Purpose:** To verify the enforcement of security policies over the O1 interface, ensuring that sensitive data remains protected through confidentiality, integrity, and replay protection. + +### Procedure and execution steps + +#### Preconditions + +- SMO, O-CU, O-DU, Near-RT RIC support TLS and be connected in simulated/real network environment. +- The O1 interface is configured for testing. +- TLS is properly implemented and configured as defined in [2] clause 4.2. + +#### Execution steps + +1. Confidentiality verification: + - Establish a secure communication session over the O1 interface. + - Capture the network traffic during the session. + - Analyse the captured traffic to verify that all data is encrypted, ensuring confidentiality. +2. Integrity protection verification: + - Capture protected packets after the TLS handshake. + - Modify the captured packets. + - Inject the modified packets to the DUT. + - Confirm that the DUT discards the injected packets, e.g., does not deliver it to the higher layer. +3. Replay protection verification: + - Capture protected packets after the TLS handshake. + - Replay the captured packets to the DUT. + - Confirm that the DUT discards the replayed packets. + +#### Expected results + +- Confidentiality: All sensitive data transmitted over the O1 interface is encrypted, with no data exposed in clear text. +- Integrity protection: The DUT detects and discards altered packets, ensuring data has not been tampered with. +- Replay protection: The DUT detects and discards replayed packets, preventing replay attacks. + +#### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs or screenshots showing TLS protocol adherence, as defined in the O-RAN Security Protocols Specifications [2] clause 4.2. +- Evidence of secure communication sessions established over the O1 interface, including details of encryption verification. +- Logs or screenshots showing the DUT's response to replayed and integrity-compromised packets, demonstrating the effectiveness of the security mechanisms in place. + +### 11.3.3 O1 Interface Network Configuration Access Control Model (NACM) Validation + +#### 11.3.3.0 Introduction + +Following zero trust principles, O-RAN O1 interface shall enforce confidentiality, integrity and authenticity through an encrypted transport, and shall support least privilege access control using the network configuration access control model. The network configuration access control model (NACM) [14] provides the means to restrict access for users to a preconfigured subset of all available NETCONF protocol operations and content. + +The security test case in this clause validates the NACM enforcement on the O-RAN component O1 interface for the role-based access control. + +#### 11.3.3.1 O1 Interface NACM Validation + +**Requirement Name:** O1 Interface security requirements + +**Requirement Reference:** REQ-NAC-FUN-1 to REQ-NAC-FUN-10, clause 5.2.2.1, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-O-RAN-02, T-O-RAN-06 + +**Requirement Description:** Requirements of O1 Interface Confidentiality, Integrity & Authenticity protection and Least Privilege Access Control + +**DUT/s:** Non-RT RIC, Near-RT RIC, O-CU-CP, O-CU-UP, O-DU + +**Test Name:** TC\_O1\_NACM\_VALIDATION + +**Purpose:** O-RAN component(s) managed by SMO through O1 interface shall support secured NETCONF sessions over TLS and role-based least privilege access control enforced by NACM [14]. This test validates the O1 interface security requirements of the O-RAN component(s) with the focus on role-based NACM rule(s) set enforcement. + +#### Procedure and execution steps + +##### Preconditions + +DUT shall be the O-RAN component with: + +- IP enabled O1 interface, reachable from the authentication server; +- Valid certificate loaded for the server and necessary certificate authorities (CAs) + +- Client's root CA required to validate NETCONF client certificate +- Valid TLS Client-to-NETCONF username mapping +- Configure the O-RAN element with the SMO details (SMO network address and port) + +**Execution steps** + +First set up a host/device with TLS client software installed, valid client certificates, keys, root CA certificate for the server (O-RAN component), and all intermediate CA certificates required to validate the client certificate. + +The following test steps shall be validated: + +1. Initiate NETCONF call home procedure from the O-RAN element towards SMO over O1 interface. + +NOTE: The O-RAN element may initiate the NETCONF call home procedure as part of its initialization automatically. + +2. SMO connects with O-RAN element over O1 interface using TLSv1.2 or TLSv1.3 - if available with a user account from the O1\_nacm\_management group +3. Verify the session is established and mapped to the correct NETCONF user +4. Verify the global NACM enforcement control setting of + - a. enable-nacm = true + - b. read-default = permit + - c. write-default = deny + - d. exec-default = deny + - e. enable-external-groups = true +5. Verify the NACM rule sets for the following pre-defined groups + - a. O1\_nacm\_management + - b. O1\_user\_management + - c. O1\_network\_management + - d. O1\_network\_monitoring + - e. O1\_software\_management for only PNFs +6. Close the NETCONF session and TLS connection + +Upon availability of the NETCONF operations set(s) definition per NACM group, the NACM rule set(s) enforcement by the DUT shall be validated for each of those pre-defined groups listed above. + +**Expected results** + +The O-RAN component supports the NETCONF over TLS session over its O1 interface and NACM enforcement control settings. + +**Expected format of evidence:** + +Logs or screenshots showing: + +- O1 interface setup. +- Valid server certificate and CA details. +- Client's root CA and intermediate CA certificates. +- TLS Client-to-NETCONF username mapping. + +- O-RAN element configured with SMO details. +- Initiation of NETCONF call home procedure. +- TLSv1.2 or TLSv1.3 connection establishment. +- Correct NETCONF user session mapping. + +## 11.4 O2 + +### 11.4.1 O2 Authenticity + +**Requirement Name:** O2 protection in terms of authenticity + +**Requirement Reference:** SEC-CTL-O-CLOUD-INTERFACE-3, clause 5.1.8.9.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-O2-01 + +**DUT/s:** SMO, O-Cloud + +**Test Name:** TC\_O2\_AUTHENTICATION + +**Purpose:** The purpose of this test is to verify the authenticity of the O2 interface, ensuring that only legitimate and authenticated O-Cloud and SMO can participate in the communication over the O2 interface. + +#### Procedure and execution steps + +##### Preconditions + +1. O-Cloud and SMO support mTLS and be connected in simulated/real network environment. +2. The test environment is set up with O2 interface configured. +3. The tester has access to the original data transported over the O2 interface. +4. mTLS is properly implemented and configured as defined in [2] clause 4.2. + +##### Execution steps + +1. Executes the tests on the mTLS protocol as defined in clause 6.3 +2. Valid Authentication Certificates (positive case): + - a. The tester sends a request to establish a connection with the O2 interface using valid authentication certificates. + - b. The tester verifies the mutual certificate verification between the ORAN NFs. + - c. The tester captures and analyses the response from the O2 interface. +3. Invalid Authentication Certificates (negative case): + - a. The tester sends a request to establish a connection with the O2 interface with invalid certificates. + - b. The tester captures and analyses the response from the O2 interface. +4. No Authentication Certificates (negative case): + - a. The tester sends a request to establish a connection without any certificates. + - b. The tester captures and analyses the response from the O2 interface. + +#### Expected results + +1. For 1. Expected results in clause 6.3 +2. For 2. ‘Valid Authentication Certificates’: The O2 interface accepts the valid certificates and respond with a successful authentication message. +3. For 3. ‘Invalid Authentication Certificates’: The connection is rejected, and an authentication failure message is received. The mutual certificate verification process fails due to the use of invalid certificates. +4. For 4. ‘No Authentication Certificates’: The connection attempt is rejected, and an authentication failure message is received. The mutual certificate verification process fails due to the absence of certificates. + +#### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +1. Logs and screenshots showing adherence to mTLS protocol specifications as defined in [2] clause 4.2. +2. Logs of authentication requests and responses on the O2 interface. +3. Logs of the mutual certificate verification process. +4. Screenshots or logs of error messages or unusual behaviours for both invalid and no certificate scenarios. + +## 11.4.2 O2 confidentiality, integrity and replay protection + +**Requirement Name:** O2 protection in terms of confidentiality, integrity and replay + +**Requirement Reference:** SEC-CTL-O-CLOUD-INTERFACE-1, clause 5.1.8.9.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-O2-01 + +**DUT/s:** SMO, O-Cloud + +**Test Name:** TC\_O2\_CONFIDENTIALITY\_INTEGRITY\_REPLAY + +**Purpose:** To verify the enforcement of security policies over the O2 interface, ensuring that sensitive data remains protected through confidentiality, integrity, and replay protection. + +#### Procedure and execution steps + +##### Preconditions + +1. O-Cloud and SMO support TLS and be connected in simulated/real network environment. +2. The O2 interface is configured for testing. +3. TLS is properly implemented and configured as defined in [2] clause 4.2. + +##### Execution steps + +1. Confidentiality verification: + - Establish a secure communication session over the O2 interface. + - Capture the network traffic during the session. + - Analyse the captured traffic to verify that all data is encrypted, ensuring confidentiality. +2. Integrity protection verification: + - Capture protected packets after the TLS handshake. + - Modify the captured packets. + +- Inject the modified packets to the DUT. +- Confirm that the DUT discards the injected packets, e.g., does not deliver it to the higher layer. + +### 3. Replay protection verification: + +- Capture protected packets after the TLS handshake. +- Replay the captured packets to the DUT. +- Confirm that the DUT discards the replayed packets. + +### Expected results + +- Confidentiality: All sensitive data transmitted over the O2 interface is encrypted, with no data exposed in clear text. +- Integrity protection: The DUT detects and discards altered packets, ensuring data has not been tampered with. +- Replay protection: The DUT detects and discards replayed packets, preventing replay attacks. + +### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs or screenshots showing TLS protocol adherence, as defined in the O-RAN Security Protocols Specifications [2] clause 4.2. +- Evidence of secure communication sessions established over the O2 interface, including details of encryption verification. +- Logs or screenshots showing the DUT's response to replayed and integrity-compromised packets, demonstrating the effectiveness of the security mechanisms in place. + +## 11.4.3 O2 Authorization + +**Requirement Name:** O2 protection in terms of authorization + +**Requirement Reference:** SEC-CTL-O-CLOUD-INTERFACE-2, clause 5.1.8.9.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-O2-01 + +**DUT/s:** SMO, O-Cloud + +**Test Name:** TC\_O2\_AUTHORIZATION + +**Purpose:** The purpose of this test is to validate that the O2 interface enforces an authorization mechanism to prevent unauthorized access. + +### Procedure and execution steps + +#### Preconditions + +- O-Cloud and SMO support OAuth 2.0 and are connected in simulated/real network environment. +- The test environment is set up with O2 interface configured. +- The tester has access to the original data transported over the O2 interface. +- OAuth 2.0 is properly implemented and configured. + +#### Execution steps + +- 1) Execute the tests on the OAuth 2.0 protocol as defined in clause 6.6 +- 2) Valid access tokens (positive case): + - a) The tester sends a request to access protected resources using a valid access token. + +- b) The tester captures and analyses the response from the O2 interface. +- 3) Invalid access tokens (negative case): + - a) The tester sends a request to access protected resources using an invalid or incorrect access token. + - b) The tester captures and analyses the response from the O2 interface. +- 4) No access tokens (negative case): + - a) The tester sends a request to access protected resources without providing any access token. + - b) The tester captures and analyses the response from the O2 interface. + +### Expected results + +- For 1. Expected results in clause 6.6 +- For 2. ‘Valid access tokens’: The O2 interface accepts the valid access tokens and responds with a successful authorization message. +- For 3. ‘Invalid access tokens’: The access is rejected, and an access failure message is received. +- For 4. ‘No access tokens’: The access is rejected due to the absence of tokens, and an appropriate error or unauthorized access message is received. + +### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +1. Logs of the request sent to access protected resources using valid access tokens. +2. Screenshots or logs highlighting the successful authorization message. +3. Logs of the request sent to access protected resources using invalid or incorrect access tokens. +4. Screenshots or logs showing the rejection of the access and the access failure message. + +## 11.5 E2 + +### 11.5.1 E2 confidentiality, integrity and replay protection + +**Requirement Name:** E2 protection in terms of confidentiality, integrity, and replay + +**Requirement Reference:** SEC-CTL-E2, SEC-CTL-NEAR-RT-2, SEC-CTL-NEAR-RT-7, clause 5.1.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05, T-NEAR-RT-01, T-NEAR-RT-02, T-NEAR-RT-03, T-NEAR-RT-04 + +**DUT/s:** O-CU, O-DU, Near-RT RIC + +**Test Name:** TC\_E2\_CONFIDENTIALITY\_INTEGRITY\_REPLAY + +**Purpose:** To verify the enforcement of security policies over the E2 interface, ensuring that sensitive data remains protected through confidentiality, integrity, and replay protection + +### Procedure and execution steps + +#### Preconditions + +- Near-RT RIC and E2 nodes support IPsec and are connected in simulated/real network environment. + +- The E2 interface is configured for testing +- The tunnel mode IPsec ESP and IKE certificate authentication is implemented. +- The tester shall base the test on the profile defined in [2] clause 4.5. + +**Execution steps** + +1. Confidentiality verification: + - Establish a secure communication session using IPsec over the E2 interface. + - Capture the network traffic during the session. + - Analyse the captured traffic to verify that all data is encrypted, ensuring confidentiality. +2. Integrity protection verification: + - Capture traffic during a secure session. + - Modify the captured packets. + - Inject the modified packets to the DUT. + - Confirm that the DUT discards the injected packets, e.g., does not deliver it to the higher layer. +3. Replay protection verification: + - Capture protected packets during a secure session and attempt to replay them. + - Replay the captured packets to the DUT. + - Confirm that the DUT discards the replayed packets. + +**Expected Results** + +- Confidentiality: All sensitive data transmitted over the E2 interface is encrypted, with no data exposed in clear text. +- Integrity protection: The DUT detects and discards altered packets, ensuring data has not been tampered with. +- Replay protection: The DUT detects and discards replayed packets, preventing replay attacks. + +**Expected format of evidence:** + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs or screenshots showing TLS protocol adherence, as defined in the O-RAN Security Protocols Specifications [2] clause 4.5. +- Evidence of secure communication sessions established over the E2 interface, including details of encryption verification. +- Logs or screenshots showing the DUT's response to replayed and integrity-compromised packets, demonstrating the effectiveness of the security mechanisms in place. + +## 11.5.2 E2 Authenticity + +### 11.5.2.1 E2 Authenticity with certificate + +**Requirement Name:** Data Authentication over E2 interface + +**Requirement Reference:** SEC-CTL-NEAR-RT-2, clause 5.1.3.2, SEC-CTL-E2-1, clause 5.2.4.2 in O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05, T-NEAR-RT-01, T-NEAR-RT-02, T-NEAR-RT-03, T-NEAR-RT-04 + +**DUT/s:** O-CU, O-DU, Near-RT RIC + +**Test Name:** TC\_E2\_AUTHENTICATION\_CERT + +**Purpose:** The purpose of this test is to verify the authenticity of the E2 interface with valid certificates, ensuring that only legitimate and authenticated Near-RT RIC and E2 nodes can participate in the communication over the E2 interface. + +### Procedure and execution steps + +#### Preconditions + +- Near-RT RIC and E2 nodes support IPsec and are connected in simulated/real network environment. +- Near-RT RIC and E2 nodes support IPsec and are configured to use certificate-based authentication. +- The test environment is set up with E2 interface configured. Communication sessions over the E2 interface are established. +- The vendor provides documentation describing how authenticity protection is achieved for the data transmission over the E2 interface. +- The tunnel mode IPsec ESP and IKE certificate authentication is implemented. +- Tester has knowledge of the security parameters of tunnel for decrypting the ESP packets. +- Tester has access to the original user data transported over the E2 interface. +- IPsec is properly implemented and configured. The tester bases the test on the profile defined in [2] clause 4.5. + +#### Execution steps + +1. Execute the tests on the IPsec protocol as defined in clause 6.5. +2. Valid Authentication Credentials: + - a. The tester sends a request to establish a connection with the E2 interface using valid certificates. + - b. The tester captures and analyses the response from the E2 interface. +3. Invalid Authentication Credentials: + - a. The tester sends a request to establish a connection with the E2 interface using invalid certificates. + - b. The tester captures and analyses the response from the E2 interface. +4. No Authentication Credentials: + - a. The tester sends a request to establish a connection with the E2 interface without providing any certificates. + - b. The tester captures and analyses the response from the E2 interface. + +#### Expected Results + +- For 1. Expected results in clause 6.5.4 +- For 2. ‘Valid Authentication Credentials’: The E2 interface accepts the valid certificate and responds with a successful authentication message. +- For 3. ‘Invalid Authentication Credentials’: The connection is rejected due to the certificate verification failure, and an authentication failure message is received. +- For 4. ‘No Authentication Credentials’: The connection attempt fails due to the absence of certificates, and an authentication failure message is received. + +### Expected format of evidence: + +- Logs and screenshots showing adherence to IPsec protocol specifications as defined in [2] clause 4.5. +- Screenshots or logs of request-response messages confirming authentication with valid credentials. +- Screenshots or logs capturing the rejection of requests with invalid credentials. +- Screenshots or logs documenting attempts to connect without credentials and their rejection. + +## 11.5.2.2 E2 Authenticity with PSK + +**Requirement Name:** Data Authentication over E2 interface + +**Requirement Reference:** SEC-CTL-NEAR-RT-2, clause 5.1.3.2, SEC-CTL-E2-1, clause 5.2.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-05, T-NEAR-RT-01, T-NEAR-RT-02, T-NEAR-RT-03, T-NEAR-RT-04 + +**DUT/s:** O-CU, O-DU, Near-RT RIC + +**Test Name:** TC\_E2\_AUTHENTICATION\_PSK + +**Purpose:** The purpose of this test is to verify the authenticity of the E2 interface with valid PSK, ensuring that only legitimate and authenticated Near-RT RIC and E2 nodes can participate in the communication over the E2 interface. + +### Procedure and execution steps + +#### Preconditions + +- Near-RT RIC and E2 nodes support IPsec and are connected in simulated/real network environment. +- Near-RT RIC and E2 nodes support IPsec and are configured to use PSK-based authentication. +- The test environment is set up with E2 interface configured. Communication sessions over the E2 interface are established. +- The vendor provides documentation describing how authenticity protection is achieved for the data transmission over the E2 interface. +- The tunnel mode IPsec ESP and IKE certificate authentication is implemented. +- Tester has knowledge of the security parameters of tunnel for decrypting the ESP packets. +- Tester has access to the original user data transported over the E2 interface. +- IPsec is properly implemented and configured. The bases the test on the profile defined in [2] clause 4.5. + +#### Execution steps + +1. Execute the tests on the IPsec protocol as defined in clause 6.5. +2. Valid Authentication Credentials: + - a. The tester sends a request to establish a connection with the E2 interface using valid PSKs. + - b. The tester captures and analyses the response from the E2 interface. +3. Invalid Authentication Credentials (Incorrect PSKs): + - a. The tester sends a request to establish a connection with the E2 interface with incorrect PSKs. + - b. The tester captures and analyses the response from the E2 interface. +4. No Authentication Credentials (No PSKs): + - a. The tester sends a request to establish a connection with the E2 interface without providing any PSKs. + - b. The tester captures and analyses the response from the E2 interface. + +## Expected Results + +- For 1. Expected results in clause 6.5.4 +- For 2. ‘Valid Authentication Credentials’: The E2 interface accepts the valid PSK and responds with a successful authentication message. +- For 3. ‘Invalid Authentication Credentials (Incorrect PSKs)’: The connection is rejected due to PSK verification failure, and an authentication failure message is received. +- For 4. ‘No Authentication Credentials (No PSKs)’: The connection attempt fails due to the absence of PSKs, and an authentication failure message is received. + +## Expected format of evidence: + +- Logs and screenshots showing adherence to IPsec protocol specifications as defined in [2] clause 4.5. +- Logs or screenshots documenting request and response messages for successful authentication using valid credentials. +- Logs or screenshots capturing the request and response messages when invalid credentials are rejected. +- Logs or screenshots documenting the request and response messages for rejections of connections without PSKs. + +## 11.5.2.3 E2 Interface data validation by Near-RT RIC + +**Requirement Name:** Validation of the data received via E2 interface by Near-RT RIC + +**Requirement Reference:** SEC-CTL-NEAR-RT-17, clause 5.1.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** The Near-RT RIC shall verify data received through the E2 interface as follows: + +The data values are valid. + +The data is being received at or below a pre-defined rate. + +The Near-RT RIC shall log security event(s) if any of the verification steps fail. + +**Threat References:** T-NEAR-RT-01, T-xApp-01 + +**DUT/s:** Near-RT RIC + +**Test Name:** TC\_E2\_Interface\_data\_validation\_by\_NearRTRIC + +**Purpose:** To validate the E2 traffic that is received by Near-RT RIC via E2 interface. The Near-RT RIC uses E2 interface to collect near real-time information (EXAMPLE:- UE basis, Cell basis) and provide value added services. These real-time information needs to be validated when it gets received at Near-RT RIC and security events are to be logged if data validation fails. E2 interface connects the Near-Real-Time RIC with other E2 nodes like O-CU, O-DU, and O-eNB. + +## Procedure and execution steps + +EXAMPLE: One of the incoming data values to the Near-RT RIC are the measurement reports (carried in E2 Indication messages) that include: + +- Channel quality reports: Signal strength, signal-to-noise ratio (SNR), and modulation quality. +- Interference reports: Identifying sources of interference. +- Load reports: Current load on E2 nodes + +## Preconditions + +Client is the test system which simulates E2 data traffic towards Near-RT RIC. This includes all the supported E2 support services (EXAMPLE:- E2 RESET procedure), Measurement reports and other supported services. Test system is also capable of simulating multiple E2 connections where E2 traffic can be pushed. + +**Precondition:** + +1. Near-RT RIC is fully operational and data value validation in Near-RT RIC is defined, and the pre-defined data threshold rate is set. By fully operational Near-RT RIC, this means the Near-RT RIC is enabled with necessary xApps and configurations at the platform level. +2. Client system is logged in and the initial control connections are up with Near-RT RIC. At this point the Near-RT RIC has subscribed with E2 Nodes in the Client system and is expecting data at a predefined rate. +3. Login to the DUT with authorized credentials and start data collection required for checking the data handling. + +### Execution steps + +1. From the client system, Initiate the E2 traffic with valid data values towards Near-RT RIC over single E2 connection +2. From the client test system, Initiate the E2 traffic with valid data on multiple E2 connections simultaneously +3. From the client test system, initiate invalid E2 traffic data + +EXAMPLE: Invalid values (or) Invalid format in the measurement reports (or) Invalid E2 Node configuration information sent in E2 setup request (or) Invalid cause in the E2 reset request +4. From the client test system, initiate the E2 data which is equal to the Near-RT RIC predefined data rate via multiple E2 connections simultaneously +5. From the client test system, initiate sudden burst of E2 data which is more than the Near-RT RIC predefined data rate via multiple E2 connections simultaneously + +### Expected results + +After step 1, the DUT processes the data traffic received over a single E2 connection. + +After step 2, the DUT processes the data traffic received simultaneously over multiple E2 connections. + +After step 3, the DUT discards the data and security event is logged with the logs fields as per clause 5.3.8.8 of [5]. + +After step 4, the DUT receives E2 traffic and handles it because E2 data is at, or below the pre-defined rate in DUT. + +After step 5, the DUT discards the spilled over data and security events are logged with the log fields are as per clause 5.3.8.8 of [5] because the E2 data rate is higher than the pre-defined rate in DUT. + +**Expected format of evidence:** Log files, traffic captures and/or report files. + +## 11.6 A1 + +### 11.6.1 A1 Authenticity + +**Requirement Name:** A1 protection in terms of authenticity + +**Requirement Reference:** SEC-CTL-A1-2, clause 5.2.1.2,n O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-A1-01 + +**DUT/s:** Non-RT RIC, Near-RT RIC + +**Test Name:** TC\_A1\_Authentication + +**Purpose:** The purpose of this test is to verify the authenticity of the A1 interface, ensuring that only legitimate and authenticated Non-RT RIC, Near-RT RIC can participate in the communication over the A1 interface. + +### Procedure and execution steps + +#### Preconditions + +- Non-RT RIC & Near-RT RIC support mTLS and be connected in a simulated/real network environment. +- The test environment is set up with the A1 interface configured. +- The tester has access to the original data transported over the A1 interface. +- mTLS is properly implemented and configured as defined in [2] clause 4.2. + +#### Execution steps + +1. Execute the test on the mTLS protocol as defined in clause 6.3. +2. Valid Authentication Certificates (positive case): + - a. The tester sends a request to establish a connection with the A1 interface using valid authentication certificates. + - b. The tester verifies the mutual certificate verification between Non-RT RIC and Near-RT RIC. + - c. The tester captures and analyses the response received from the A1 interface. +3. Invalid Authentication Certificates (negative case): + - a. The tester sends a request to establish a connection with the A1 interface with invalid certificates. + - b. The tester captures and analyses the response received from the A1 interface. +4. No Authentication Certificates (negative Case): + - a. The tester sends a request to establish a connection without any certificates. + - b. The tester captures and analyses the response from the A1 interface. + +#### Expected results + +- For 1. Expected results in clause 6.3 +- For 2. 'Valid Authentication Certificates': The A1 interface accepts the valid certificates and responds with a successful authentication message. The mutual certificate verification process is successful. +- For 3. 'Invalid Authentication Certificates': The connection attempt is rejected, and an authentication failure message is received. The mutual certificate verification process fails due to the use of invalid certificates. +- For 4. 'No Authentication Certificates': The connection attempt is rejected, and an authentication failure message is received. The mutual certificate verification process fails due to the absence of certificates. + +#### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs and screenshots showing adherence to mTLS protocol specifications as defined in [2] clause 4.2. +- Logs of authentication requests and responses on the A1 interface. +- Logs of the mutual certificate verification process. +- Screenshots or logs of error messages or unusual behaviours for both invalid and no certificate scenarios. + +## 11.6.2 A1 confidentiality, integrity and replay protection + +**Requirement Name:** A1 protection in terms of confidentiality, integrity, and replay + +**Requirement Reference:** SEC-CTL-A1, clause 5.2.1.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-A1-02, T-A1-03 + +**DUT/s:** Non-RT RIC, Near-RT RIC + +**Test Name:** TC\_A1\_CONFIDENTIALITY\_INTEGRITY\_REPLAY + +**Purpose:** To verify the enforcement of security policies over the A1 interface, ensuring that sensitive data remains protected through confidentiality, integrity, and replay protection. + +### Procedure and execution steps + +#### Preconditions + +- Non-RT RIC & Near-RT RIC support TLS and connected within simulated or real network environments. +- The A1 interface is configured for testing. +- TLS is properly implemented and configured as defined in [2] clause 4.2. + +#### Execution steps + +1. Confidentiality verification: + - Establish a secure communication session over the A1 interface. + - Capture the network traffic during the session. + - Analyze the captured traffic to verify that all data is encrypted, ensuring confidentiality. +2. Integrity protection verification: + - Capture protected packets after the TLS handshake. + - Modify the captured packets. + - Inject the modified packets to the DUT. + - Confirm that the DUT discards the injected packets, e.g., does not deliver it to the higher layer. +3. Replay protection verification: + - Capture protected packets after the TLS handshake. + - Replay the captured packets to the DUT. + - Confirm that the DUT discards the replayed packets. + +#### Expected results + +- Confidentiality: All sensitive data transmitted over the A1 interface is encrypted, with no data exposed in clear text. +- Integrity protection: The DUT detects and discards altered packets, ensuring data has not been tampered with. +- Replay protection: The DUT detects and discards replayed packets, preventing replay attacks. + +#### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs or screenshots showing TLS protocol adherence, as defined in the O-RAN Security Protocols Specifications [2] clause 4.2. +- Evidence of secure communication sessions established over the A1 interface, including details of encryption verification. +- Logs or screenshots showing the DUT's response to replayed and integrity-compromised packets, demonstrating the effectiveness of the security mechanisms in place. + +## 11.6.3 A1 Authorization + +**Requirement Name:** A1 protection in terms of authorization + +**Requirement Reference:** SEC-CTL-A1-3, clause 5.2.1.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-A1-01 + +**DUT/s:** Non-RT RIC, Near-RT RIC + +**Test Name:** TC\_A1\_Authorization + +**Purpose:** The purpose of this test is to validate that the A1 interface enforces an authorization mechanism to prevent unauthorized access. + +### Procedure and execution steps + +#### Preconditions + +- Non-RT RIC and Near-RT RIC support OAuth 2.0 and are connected in simulated/real network environment. +- The test environment is set up with A1 interface configured. +- The tester has access to the original data transported over the A1 interface. +- OAuth 2.0 is properly implemented and configured. + +#### Execution steps + +1. Execute the test on the OAuth 2.0 protocol as defined in clause 6.6. +2. Valid access tokens (positive case): + - a. The tester sends a request to access protected resources using a valid access token. + - b. The tester captures and analyses the response from the A1 interface. +3. Invalid access tokens (negative case): + - a. The tester sends a request to access protected resources using an invalid or incorrect access token. + - b. The tester captures and analyses the response from the A1 interface. +4. No access tokens (negative case): + - a. The tester sends a request to access protected resources without providing any access token. + - b. The tester captures and analyses the response from the A1 interface. + +#### Expected Results + +- For 1. Expected results in clause 6.6 +- For 2. 'Valid access tokens': The A1 interface accepts the valid access tokens and responds with a successful authorization message. +- For 3. 'Invalid access tokens': The access is rejected, and an access failure message is received. +- For 4. 'No access tokens': The access is rejected due to the absence of tokens, and an appropriate error or unauthorized access message is received. + +#### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs of the request sent to access protected resources using valid access tokens. +- Screenshots or logs highlighting the successful authorization message. +- Logs of the request sent to access protected resources using invalid or incorrect access tokens. +- Screenshots or logs showing the rejection of the access and the access failure message. + +## 11.7 R1 + +### 11.7.1 R1 Authenticity + +**Requirement Name:** R1 protection in terms of authenticity + +**Requirement Reference:** SEC-CTL-R1-2, clause 5.2.6.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-R1-03 + +**DUT/s:** Non-RT RIC, rApps + +**Test Name:** TC\_R1\_AUTHENTICATION + +**Purpose:** The purpose of this test is to verify the authenticity of the R1 interface, ensuring that only legitimate and authenticated Non-RT RIC, rApps can participate in the communication over the R1 interface. + +#### Procedure and execution steps + +##### Preconditions + +- Non-RT RIC & rApps support mTLS and be connected in a simulated/real network environment. +- The test environment is set up with the R1 interface configured. +- The tester has access to the original data transported over the R1 interface. +- mTLS is properly implemented and configured as defined in [2] clause 4.2. + +##### Execution steps + +1. Execute the test on the mTLS protocol as defined in clause 6.3. +2. Valid Authentication Certificates (positive case): + - a. The tester sends a request to establish a connection with the R1 interface using valid authentication certificates. + - b. The tester verifies the mutual certificate verification between Non-RT RIC and rApps. + - c. The tester captures and analyses the response received from the R1 interface. +3. Invalid Authentication Certificates (negative case): + - a. The tester sends a request to establish a connection with the R1 interface with invalid certificates. + - b. The tester captures and analyses the response received from the R1 interface. +4. No Authentication Certificates (negative Case): + - a. The tester sends a request to establish a connection without any certificates. + - b. The tester captures and analyses the response from the R1 interface. + +##### Expected results + +For 1. Expected results in clause 6.3 + +For 2. ‘Valid Authentication Certificates’: The R1 interface accepts the valid certificates and responds with a successful authentication message. The mutual certificate verification process is successful. + +For 3. ‘Invalid Authentication Certificates’: The connection attempt is rejected, and an authentication failure message is received. The mutual certificate verification process fails due to the use of invalid certificates. + +For 4. ‘No Authentication Certificates’: The connection attempt is rejected, and an authentication failure message is received. The mutual certificate verification process fails due to the absence of certificates. + +#### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs and screenshots showing adherence to mTLS protocol specifications as defined in [2] clause 4.2. +- Logs of authentication requests and responses on the R1 interface. +- Logs of the mutual certificate verification process. +- Screenshots or logs of error messages or unusual behaviours for both invalid and no certificate scenarios. + +## 11.7.2 R1 confidentiality, integrity and replay protection + +**Requirement Name:** R1 protection in terms of confidentiality, integrity and replay + +**Requirement Reference:** SEC-CTL-R1-1, clause 5.2.6.2, O-RAN Security Requirements and Controls Specifications [5] + +#### Requirement Description: + +**Threat References:** T-R1-06, T-R1-07 + +**DUT/s:** Non-RT RIC, rApps + +**Test Name:** TC\_R1\_CONFIDENTIALITY\_INTEGRITY\_REPLAY + +**Purpose:** To verify the enforcement of security policies over the R1 interface, ensuring that sensitive data remains protected through confidentiality, integrity and replay protection. + +#### Procedure and execution steps + +##### Preconditions + +- Non-RT RIC & rApps supporting TLS, connected within simulated or real network environments. +- The R1 interface is configured for testing. +- TLS is properly implemented and configured as defined in [2] clause 4.2. + +##### Execution steps + +1. Confidentiality verification: + - Establish a secure communication session over the R1 interface. + - Capture the network traffic during the session. + - Analyze the captured traffic to verify that all data is encrypted, ensuring confidentiality. +2. Integrity protection verification: + - Capture protected packets after the TLS handshake. + - Modify the captured packets. + - Inject the modified packets to the DUT. + - Confirm that the DUT discards the injected packets, e.g., does not deliver it to the higher layer. +3. Replay protection verification: + - Capture protected packets after the TLS handshake. + - Replay the captured packets to the DUT. + - Confirm that the DUT discards the replayed packets. + +##### Expected results + +- Confidentiality: All sensitive data transmitted over the R1 interface is encrypted, with no data exposed in clear text. +- Integrity protection: The DUT detects and discards altered packets, ensuring data has not been tampered with. +- Replay protection: The DUT detects and discards replayed packets, preventing replay attacks. + +#### Expected Format of Evidence: + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs or screenshots showing TLS protocol adherence, as defined in the O-RAN Security Protocols Specifications [2] clause 4.2. +- Evidence of secure communication sessions established over the R1 interface, including details of encryption verification. +- Logs or screenshots showing the DUT's response to replayed and integrity-compromised packets, demonstrating the effectiveness of the security mechanisms in place. + +### 11.7.3 R1 Authorization + +**Requirement Name:** R1 protection in terms of authorization + +**Requirement Reference:** SEC-CTL-R1-3, clause 5.2.6.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-R1-01, T-R1-04, T-R1-05 + +**DUT/s:** Non-RT RIC, rApps + +**Test Name:** TC\_R1\_AUTHORIZATION + +**Purpose:** The purpose of this test is to validate that the R1 interface enforces an authorization mechanism to prevent unauthorized access. + +#### Procedure and execution steps + +##### Preconditions + +- Non-RT RIC and rApps support OAuth 2.0 and are connected in simulated/real network environment. +- The test environment is set up with R1 interface configured. +- The tester has access to the original data transported over the R1 interface. +- OAuth 2.0 is properly implemented and configured. + +##### Execution steps + +1. Execute the test on the OAuth 2.0 protocol as defined in clause 6.6. +2. Valid access tokens (positive case): + - a. The tester sends a request to access protected resources using a valid access token. + - b. The tester captures and analyses the response from the R1 interface. +3. Invalid access tokens (negative case): + - a. The tester sends a request to access protected resources using an invalid or incorrect access token. + - b. The tester captures and analyses the response from the R1 interface. +4. No access tokens (negative case): + - a. The tester sends a request to access protected resources without providing any access token. + - b. The tester captures and analyses the response from the R1 interface. + +##### Expected Results + +1. For 1. Expected results in clause 6.6 + +2. For 2. 'Valid access tokens': The R1 interface accepts the valid access tokens and responds with a successful authorization message. +3. For 3. 'Invalid access tokens': The access is rejected, and an access failure message is received. +4. For 4. 'No access tokens': The access is rejected due to the absence of tokens, and an appropriate error or unauthorized access message is received. + +**Expected Format of Evidence:** + +The following evidence, in one or more formats as applicable, should be provided: + +- Logs of the request sent to access protected resources using valid access tokens. +- Screenshots or logs highlighting the successful authorization message. +- Logs of the request sent to access protected resources using invalid or incorrect access tokens. +- Screenshots or logs showing the rejection of the access and the access failure message. + +--- + +## 12 Security test of O-RU + +### 12.1 Overview + +This clause contains security tests to validate the security protection mechanism specific to O-RU. + +### 12.2 SSH on M-Plane interface + +**Requirement Name:** Network Security Protocol - SSH + +**Requirement Reference:** Clause 5.4, O-RAN WG4 Management Plane Specification [21] + +**Requirement Description:** Robust protocol implementation with adequately strong cipher suites is being required for SSH + +**Threat References:** T-O-RAN-05 + +**DUT/s:** O-RU + +**Test name:** TC\_SSH\_MPlane + +**Purpose:** To verify implementation of the SSH protocol in O-RU along with validation of supported SSH version and robustness of cryptographic algorithms used for host key, symmetric encryption, key exchange, and MACs as specified in [21] + +**Procedure and execution steps****Preconditions** + +DUT is the O-RU with SSH service enabled as server. Client is a test equipment with SSH audit tool which is used for server-side testing. + +**Execution steps** + +This test case follows the "server-side testing" procedure for SSH specified in TC\_SSH\_Server\_and\_Client\_Protocol, clause 6.2 of the present document. + +**Expected results** + +O-RU as SSH server supports only SSHv2 version with no older version supported and algorithms (for host key, symmetric encryption, key exchange, and MACs) defined in clause 5.4 of [21]. + +**Expected format of evidence:** As defined in clause 6.2 of the present document. + +## 12.3 TLS on M-Plane interface + +**Requirement Name:** Network Security Protocol - TLS + +**Requirement Reference:** Clause 5.4, O-RAN WG4 Management Plane Specification [21] + +**Requirement Description:** Support TLS v1.2 and/or TLS v1.3 with protocol profiles + +**Threat References:** T-O-RAN-05 + +**DUT/s:** O-RU + +**Test name:** TC\_TLS\_MPlane + +**Purpose:** To verify implementation of the TLS protocol in O-RU along with validation of mandated/optional TLS versions and cipher suites specified in clause 5.4 of [21]. Since NETCONF implementations support X.509v3 certificate-based authentication using TLS 1.2, mutual authentication shall also be tested using both valid and invalid client certificates. + +### Procedure and execution steps + +#### Preconditions + +DUT is the O-RU with TLS service enabled as server equipped with CA cert for signing client certificate(s). Client is a testing equipment with TLS scanning tool with client certificate(s). + +#### Execution steps + +This test case follows the execution steps for TLS specified in TC\_TLS\_Protocol, clause 6.3 of the present document. + +#### Expected results + +O-RU as TLS server shall support TLS starting from version 1.2 with no older version enabled along with protocol profiles/Cipher suites defined in clause 5.4 of [21]. + +**Expected format of evidence:** As defined in clause 6.3 of the present document. + +## 12.4 Security functional requirements and test cases + +The 802.1X Supplicant Validation test cases in clause 11.2.2 of the present document apply to O-RU. + +--- + +# 13 Security test of Near-RT RIC + +## 13.1 Overview + +This clause contains security tests to validate the security protection mechanism specific to Near-RT RIC. + +## 13.2 Void + +## 13.3 Transactional APIs + +### 13.3.1 Introduction + +Transactional APIs in the Near-RT RIC are APIs that are based on HTTP/TLS, i.e. APIs based on REST or gRPC. + +### 13.3.2 TLS for transactional APIs + +**Requirement Name:** TLS for transactional APIs + +**Requirement Reference:** SEC-CTL-NEAR-RT-6, clause 5.1.3.2, O-RAN Security Requirements and Controls Specifications [5]. + +**Requirement Description:** “Transactional APIs (REST and gRPC) shall support TLS to provide message confidentiality and integrity.” + +**Threat References:** T-NEAR-RT-01, T-NEAR-RT-02, T-NEAR-RT-03, T-NEAR-RT-04 + +**DUT/s:** xApp, Near-RT RIC + +**Test name:** TC\_TLS\_APIs + +**Purpose:** To verify the transactional APIs (REST and gRPC) support TLS to provide message confidentiality and integrity. + +#### Procedure and execution steps + +##### Preconditions + +DUT is configured and with TLS support enabled. + +The other end may be simulated or a testing equipment. + +##### Execution steps + +This test case follows the execution steps for TLS specified in TLS Execution steps, clause 6.3 of the present document. + +##### Expected results + +The transaction APIs provides confidentiality and integrity protection for data in transit. + +**Expected format of evidence:** Tool reports, log files, traffic captures and/or screenshots. + +### 13.3.3 mTLS for transactional APIs + +**Requirement Name:** mTLS for transactional APIs + +**Requirement Reference:** REQ-SEC-NEAR-RT-3, clause 5.1.3.2, O-RAN Security Requirements and Controls Specifications [5]. + +**Requirement Description:** “The communication between xApps and Near-RT RIC platform APIs shall be mutually authenticated.” + +**Threat References:** T-NEAR-RT-01, T-NEAR-RT-02, T-NEAR-RT-03, T-NEAR-RT-04 + +**DUT/s:** xApp, Near-RT RIC + +**Test Name:** TC\_mTLS\_APIs + +**Purpose:** To verify the transactional APIs (REST and gRPC) support mutual TLS (mTLS) authentication via X.509v3 certificates. + +**Procedure and execution steps** + +Applicability: DUTs that support mTLS as a mutual authentication mechanism. + +**Preconditions** + +DUT is configured and with mTLS support enabled. The other end may be simulated or a testing equipment. + +**Execution steps** + +This test case follows the execution steps for TLS specified in TLS Execution steps, clause 6.3 of the present document. + +**Expected results** + +The transaction APIs supports mutual TLS (mTLS) authentication. + +**Expected format of evidence:** Tool reports, log files, traffic captures and/or screenshots. + +## 13.3.4 OAuth 2.0 for transactional APIs + +**Requirement Name:** OAuth 2.0 for transactional APIs + +**Requirement Reference:** REQ-SEC-NEAR-RT-4, REQ-SEC-NEAR-RT-5, clause 5.1.3.1, O-RAN Security Requirements and Controls Specifications [5]. + +**Requirement Description:** Near-RT RIC architecture provides an authorization framework. + +**Threat References:** T-NEAR-RT-01, T-NEAR-RT-02, T-NEAR-RT-03, T-NEAR-RT-04 + +**DUT/s:** xApp, Near-RT RIC + +**Test Name:** TC\_OAuth2.0\_API + +**Purpose:** To verify the transactional APIs (REST and gRPC) in the DUT support the OAuth 2.0 authorization framework. + +**Procedure and execution steps** + +**Preconditions** + +DUT is configured and with OAuth 2.0 support enabled. + +The other end may be simulated or a testing equipment. + +**Execution steps** + +This test case follows the execution steps for OAuth2.0 specified in OAuth Execution steps, clause 6.6 of the present document. + +**Expected results** + +The transaction APIs supports the use of OAuth 2.0. + +**Expected format of evidence:** Tool reports, log files, traffic captures and/or screenshots. + +## 13.4 Security test of Near-RT RIC OAuth 2.0 Resource Owner/Server + +### 13.4.1 Overview + +This clause contains security tests to verify OAuth2.0 implementation on Near-RT RIC as resource owner/server for A1-P. + +### 13.4.2 Near-RT RIC OAuth 2.0 Resource Owner/Server + +**Requirement Name:** Near-RT RIC support as OAuth2.0 resource owner/server + +**Requirement Reference:** Clause 5.1.3.2, Security Controls, Near-RT RIC and xApps, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** OAuth 2.0 security controls for Near-RT RIC authorization of service requests + +**Threat References:** T-NEAR-RT-01, T-NEAR-RT-02, T-NEAR-RT-03, T-NEAR-RT-04 + +**DUT/s:** Near-RT RIC + +**Test Name:** TC\_NearRTRIC\_OAuth2.0\_Server + +**Purpose:** To validate the Near-RT RIC support as OAuth 2.0 resource owner/server for A1-P, as specified in clause 4.7, O-RAN Security Protocols Specifications [2] for service requests received from a Near-RT RIC. + +#### Procedure and execution steps + +#### Preconditions + +DUT is acting as a resource owner/server with OAuth 2.0 support enabled. OAuth2.0 Client is the test system equipped to send the service requests over a secured TLS communication with mutual TLS authentication. + +#### Execution steps + +This test case shall follow execution steps for OAuth2.0 specified in clause 6.6 of the present document. + +#### Expected results + +The Near-RT RIC shall be able to authorize/deny access to resources using OAuth 2.0. + +**Expected format of evidence:** Log files, traffic captures and/or report files. + +## 13.5 Security test of Near-RT RIC OAuth 2.0 client + +### 13.5.1 Overview + +This clause contains security tests to verify the implementation on Near-RT RIC as OAuth2.0 client for A1-EI. + +### 13.5.2 Near-RT RIC OAuth 2.0 client + +**Requirement Name:** Near-RT RIC support as OAuth2.0 client for A1-EI + +**Requirement Reference:** Clause 5.1.3.2, Security Controls, Near-RT RIC and xApps, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** OAuth 2.0 security controls for Near-RT RIC authorization of service requests + +**Threat References:** T-NEAR-RT-01, T-NEAR-RT-02, T-NEAR-RT-03, T-NEAR-RT-04 + +**DUT/s:** Near-RT RIC + +**Test Name:** TC\_NearRTRIC\_OAuth2.0\_Client + +**Purpose:** To validate the Near-RT RIC support as OAuth 2.0 client for A1-EI, as specified in clause 4.7, O-RAN-Security Protocols Specifications [2] + +**Procedure and execution steps** + +**Preconditions** + +DUT is acting as a resource client with OAuth 2.0 support enabled. + +**Execution steps** + +This test case shall follow execution steps for OAuth2.0 specified in clause 6.6 of the present document. + +**Expected results** + +The Near-RT RIC shall be able to request and be permitted access to resources using OAuth2.0 + +**Expected format of evidence:** Log files, traffic captures and/or report files. + +--- + +## 14 Security test of xApps + +### 14.1 Overview + +This clause contains security tests to validate the security protection mechanism specific to xApps deployed on Near-RT RIC. + +### 14.2 xApp Signing and Verification + +Security test cases "TC\_SW\_Img\_Pkg\_Signing" and "TC\_SW\_Img\_Pkg\_Verification" apply to this clause. + +### 14.3 xAppID + +This clause contains security tests to validate the xApp ID which is a string that uniquely identifies the xApp instance. The format of this string is a Universally Unique Identifier (UUID) version 4 (as described in IETF RFC 9562 [30]). + +#### 14.3.1 xApp ID format check + +**Requirement Name:** xApp ID uniqueness check for the xApp instance + +**Requirement Reference:** SEC-CTL-NEAR-RT-13, clause 5.1.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** To validate the format of xApp ID string and the uniqueness of the same which will be a Universally Unique Identifier (UUID) version 4 (as described in IETF RFC 9562 [30]). + +**Threat References:** T-NEAR-RT-05 + +**DUT/s:** Near-RT RIC + +**Test Name:** TC\_xApp\_ID\_validation + +**Purpose:** To validate the xApp ID format that uniquely identifies the xApp instance. In this test, we are initiating registration requests from 3 xApp instances and validating the response from Near-RT RIC. The xApp ID format is checked against Universally Unique Identifier (UUID) version 4 (as described in IETF RFC 9562 [30]). + +#### **Procedure and execution steps** + +##### **Preconditions** + +xApp instances are pre-provisioned with initial registration credential (OAuth 2.0 token), and the xApp instance CSR message. + +NOTE: xApp instances can be instantiated of the same or different xApp images + +##### **Execution steps** + +1. Initiate the first xApp instance registration procedure with DUT and get for the registration response. +2. Initiate the second xApp instance registration procedure with DUT and get for the registration response. +3. Initiate the third xApp instance registration procedure with DUT and get for the registration response. + +##### **Expected results** + +After each execution step, the Registration response from DUT includes the xApp certificate for the xApp instance. The field "Subject Alternative Name" in the xApp instance certificate contains URI for the xApp ID as an URN. This URI contains the xApp ID of the different xApp instances. + +The xApp ID generated in SAN field of xApp instance certificate after each execution step is unique and different from the others. + +The assigned xApp ID format is complaint with Universally Unique Identifier (UUID) version 4 (as described in IETF RFC 9562 [30]). + +NOTE: the certificate details could be seen with the openssl tool + +**Expected format of evidence:** Log files, traffic captures, report files, certificates and/or screenshots. + +## **14.3.2 xApp ID in xApp instance Certificate** + +**Requirement Name:** xApp ID presence in "Subject Alternative Name" field of the xApp instance certificate. + +**Requirement Reference:** SEC-CTL-NEAR-RT-14, clause 5.1.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** "Subject Alternative Name" in the xApp instance certificate contains URI for the xApp ID as an URN. This URI contains the xApp ID of the xApp instance using the UUID format as described in IETF RFC 9562 [30]. + +**Threat References:** T-xApp-02, T-NEAR-TR-05 + +**DUT/s:** Near-RT RIC + +**Test Name:** TC\_xApp\_ID\_check\_in\_xApp\_instance\_certificate + +**Purpose:** To check the xApp ID embedded in subject Alternate Name field of xApp instance certificate. + +#### **Procedure and execution steps** + +**Preconditions** + +xApp image is available for instantiation. + +xApp Registration procedure is successfully done and xApp instance certificate has been assigned to xApp as part of the Registration response. + +**Execution steps** + +1. Establish a TLS session to the xApp instance with authorized credentials. + +EXAMPLE: TLS session may be established using one of the services that xApp instance provides + +2. Capture the xApp instance certificate (X.509v3) on the xApp instance and open the certificate to check the details. + +EXAMPLE: `Openssl x509 -in -text -noout` + +3. Check the "Subject Alternative Name" field in the certificate details. + +**Expected results** + +The "Subject Alternative Name" contained in the certificate of the xApp instance, contains URI for the xApp ID as an URN. xApp ID of the xApp instance is conformant to UUID format as described in IETF RFC 9562 [30]. + +**Expected format of evidence:** Log files, traffic captures, screenshots, certificates and/or report files. + +--- + +## 15 Security test of Non-RT RIC + +### 15.1 Overview + +This clause contains security tests to validate the security protection mechanism specific to Non-RT RIC and the R1 and A1 interfaces. Security test cases for rApps are covered in a separate sub-clause. + +### 15.2 Non-RT RIC + +Following zero trust principles, O-RAN Non-RT RIC shall enforce authorization using OAuth 2.0 + +#### 15.2.1 Non-RT RIC OAuth 2.0 Resource Owner/Server + +**Requirement Name:** Server authorization support + +**Requirement Reference:** REQ-SEC-NonRTRIC-1, clause 5.1.2.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Non-RT RIC supports OAuth 2.0 as a Server + +**Threat References:** T-NONRTRIC-01, T-NONRTRIC-02, T-NONRTRIC-03 + +**DUT/s:** Non-RT RIC + +**Test Name:** TC\_NonRTRIC\_OAuth2.0\_Server + +**Purpose:** To verify the Non-RT RIC supports OAuth 2.0 resource owner/server for A1-EI. + +**Procedure and execution steps****Preconditions** + +The DUT is acting as a Resource Owner/Server and has OAuth 2.0 support enabled. + +The rest of the elements of the setup may be real or simulated. + +#### **Execution steps** + +This test case follows the execution steps for OAuth2.0 specified in OAuth Execution steps, clause 6.6. + +#### **Expected results** + +The Non-RT RIC is able to authorize/deny access to resources using OAuth 2.0. + +**Expected format of evidence:** Log files, traffic captures and/or report files. + +## 15.2.2 Non-RT RIC OAuth 2.0 Client + +**Requirement Name:** Client authorization support + +**Requirement Reference:** REQ-SEC-NonRTRIC-1, clause 5.1.2.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Non-RT RIC supports OAuth 2.0 as a Client + +**Threat References:** T-NONRTRIC-01, T-NONRTRIC-02, T-NONRTRIC-03 + +**DUT/s:** Non-RT RIC + +**Test Name:** TC\_NonRTRIC\_OAuth2.0\_Client + +**Purpose:** To verify the Non-RT RIC supports OAuth 2.0 client for A1-P. + +#### **Procedure and execution steps** + +##### **Preconditions** + +The DUT is acting as a Client and has OAuth 2.0 support enabled. + +The rest of the elements of the setup may be real or simulated. + +##### **Execution steps** + +This test case follows the execution steps for OAuth2.0 specified in OAuth Execution steps, clause 6.6. + +##### **Expected results** + +The Non-RT RIC is able to request and be permitted access to resources using OAuth 2.0. + +**Expected format of evidence:** Log files, traffic captures and/or report files. + +## 15.2.3 Non-RT RIC Framework OAuth 2.0 + +**Requirement Name:** Framework Server authorization support + +**Requirement Reference:** REQ-SEC-NonRTRIC-2, clause 5.1.2.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Non-RT RIC Framework supports OAuth 2.0 as a Server + +**Threat References:** T-NONRTRIC-01, T-NONRTRIC-02, T-NONRTRIC-03 + +**DUT/s:** Non-RT RIC + +**Test Name:** TC\_NonRTRIC\_OAuth2.0\_Framework\_Server + +**Purpose:** To verify the Non-RT RIC Framework supports OAuth 2.0 as a resource owner/server. + +**Procedure and execution steps** + +**Preconditions** + +The DUT is acting as a Resource Owner and has OAuth 2.0 support enabled. + +The rest of the elements of the setup may be real or simulated. + +**Execution steps** + +This test case follows the execution steps for OAuth2.0 specified in OAuth Execution steps, clause 6.6. + +**Expected results** + +The Non-RT RIC Framework is able to authorize access to resources using OAuth 2.0. + +**Expected format of evidence:** Log files, traffic captures and/or report files. + +## 15.3 R1 interface + +Void + +## 15.4 A1 interface + +Void + +--- + +# 16 Security test of rApps + +## 16.1 Overview + +This clause contains security tests to validate the security protection mechanism specific to rApps deployed on Non-RT RIC. + +## 16.2 rApp Signing and Verification + +Security test cases "TC\_SW\_Img\_Pkg\_Signing" and "TC\_SW\_Img\_Pkg\_Verification" apply to this clause. + +## 16.3 rApp Authorization + +### 16.3.1 rApp OAuth 2.0 Client + +**Requirement Name:** rApp OAuth2.0 Client support + +**Requirement Reference:** REQ-SEC-NonRTRIC-3, clause 5.1.2.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** "rApps shall provide client authorization requests to the Non-RT RIC Framework." + +**Threat References:** T-rAPP-04 + +**DUT/s:** rApps + +**Test Name:** TC\_OAuth2.0\_rApp + +**Purpose:** To verify the rApp supports OAuth 2.0 client. + +**Procedure and execution steps** + +**Preconditions** + +The DUT is acting as an OAuth2.0 Client with OAuth 2.0 support enabled. + +The rest of the elements of the setup may be real or simulated. + +**Execution steps** + +This test case follows the execution steps for OAuth2.0 specified in OAuth Execution steps, clause 6.6. + +**Expected results** + +The rApp is able to request access and be permitted access to resources using OAuth 2.0. + +**Expected format of evidence:** Log files, traffic captures and/or report files. + +--- + +## 17 Security test of SMO + +### 17.1 Overview + +This clause contains security tests to validate security protection mechanisms related to the SMO. The test cases validate the security of SMO termination of O1 interfaces, SMO, SMO Services (SMOS) Communications, SMO External Interfaces, and SMO Logging are secured to zero trust principles for confidentiality, integrity, authentication, and authorization. Definitions for the O-RAN terms SMO Service (SMOS), SMO Function (SMOF), SMO External Interfaces, and SMO External System are provided in [1]. + +The test cases apply to the normative security requirements specified in [5] based upon the following approved security architecture: + +The SMO enforces confidentiality, integrity and authenticity through an encrypted transport for the O1 interface and supports least privilege access control using the network configuration access control model (NACM) for authorization. + +The SMO supports mutual authentication and authorization of SMO Functions (SMOF) and External Interfaces. + +SMO Internal Communications provide communication and services between the SMO, SMOFs, Non-RT RIC Functions, and rApps. SMO Internal Communications shall provide confidentiality and integrity protection of data in transit and shall support mutual authentication and authorization for access to services and resources. + +SMO External Interfaces provide import of AI enrichment data from external data sources to the SMO. SMO External Interfaces shall provide confidentiality and integrity protection of data in transit and shall support mutual authentication and authorization for access to services and resources. + +## 17.2 Void + +## 17.3 SMO + +### 17.3.1 SMO OAuth 2.0 Resource Owner/Server + +**Requirement Name:** SEC-CTL-SMO-3 + +**Requirement Reference:** Clause 5.1.1.2.1, Security Controls, SMO, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** OAuth 2.0 security controls for SMO to authorize service requests from SMO Functions. + +**Threat References:** T-SMO-02, T-SMO-05 + +**DUT/s:** SMO, SMO Functions + +**Test Name:** TC\_SMO\_OAuth2.0\_Resource\_Owner\_Server + +**Purpose:** To verify the SMO shall support OAuth 2.0 resource owner/server. + +**Procedure and execution steps** + +**Preconditions** + +DUT shall be the SMO with OAuth 2.0 support enabled. + +**Execution steps** + +This test case shall follow the execution steps for OAuth2.0 specified in OAuth Execution steps, clause 6.6. + +**Expected results** + +The SMO shall be able to authorize/deny access requests received from SMO Functions using OAuth 2.0. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +### 17.3.2 SMO OAuth 2.0 Client + +**Requirement Name:** SEC-CTL-SMO-4 + +**Requirement Reference:** Clause 5.1.1.2.1, Security Controls, SMO, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** OAuth 2.0 security controls for SMO to support client functionality for service requests to other SMO Functions + +**Threat References:** T-SMO-02, T-SMO-05 + +**DUT/s:** SMO + +**Test Name:** TC\_SMO\_OAuth2.0\_Client + +**Purpose:** To verify the SMO supports OAuth 2.0 client. + +**Procedure and execution steps** + +**Preconditions** + +DUT shall be the SMO with OAuth 2.0 support enabled. + +#### Execution steps + +This test case follows the execution steps for OAuth2.0 specified in OAuth Execution steps, clause 6.6. + +#### Expected results + +The SMO shall be able to request and be permitted/denied access to resources using OAuth 2.0. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +### 17.3.3 SMO mTLS for mutual authentication + +**Requirement Name:** SEC-CTL-SMO-5 + +**Requirement Reference:** Clause 5.1.1.2.1, Security Controls, SMO, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** SMO support mTLS for mutual authentication with SMO Functions. + +**Threat References:** T-SMO-01, T-SMO-04 + +**DUT/s:** SMO + +**Test Name:** TC\_SMO\_mTLS + +**Purpose:** To verify the SMO supports mutual authentication with SMO Functions using mTLS, with PKI and X.509 certificates. + +#### Procedure and execution steps + +#### Preconditions + +DUT shall be the SMO with mTLS support enabled. An external OAuth 2.0 Authorization Server is available and configured. + +#### Execution steps + +This test case follows the execution steps for mTLS specified in mTLS Execution steps, clause 6.3. + +#### Expected results + +The SMO shall support mutual authentication of SMO Functions using mTLS. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +## 17.4 SMO Internal Communications + +### 17.4.1 TLS for SMO Internal Communications + +**Requirement Name:** SEC-CTL-SMO-Internal-1 + +**Requirement Reference:** Clause 5.1.1.2.2, Security Controls, SMO Internal Communications, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Data in transit protection with TLS for SMO Internal Communications + +**Threat References:** T-SMO-09 + +**DUT/s:** SMO, Non-RT RIC + +**Test Name:** TC\_SMO\_TLS\_Internal\_Communications + +**Purpose:** To verify the SMO supports TLS on SMO Internal Communications. + +**Procedure and execution steps** + +**Preconditions** + +DUT shall be the SMO with TLS support enabled. + +**Execution steps** + +This test case shall follow the execution steps for TLS specified in TLS Execution steps, clause 6.3. + +**Expected results** + +SMO Internal Communications shall provide confidentiality and integrity protection using TLS for data in transit. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +## 17.4.2 mTLS for SMO Internal Communications – SMO Functions + +**Requirement Name:** SEC-CTL-SMO-Internal-2 + +**Requirement Reference:** Clause 5.1.1.2.2, Security Controls, SMO Internal Communications, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Mutual authentication with mTLS for SMO Internal Communications + +**Threat References:** T-SMO-01, T-SMO-04 + +**DUT/s:** SMO + +**Test Name:** TC\_SMO\_mTLS\_Internal\_Communications + +**Purpose:** To verify SMO Functions support mutual authentication using mTLS, with PKI and X.509 certificates, for SMO Internal Communications. + +**Procedure and execution steps** + +**Preconditions** + +DUT shall be the SMO Function with mTLS support enabled. + +**Execution steps** + +This test case follows the execution steps for mTLS specified in mTLS Execution steps, clause 6.3. + +**Expected results** + +The SMO Function shall support mutual authentication using mTLS. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +## 17.5 SMO External Interfaces + +### 17.5.1 TLS for SMO External Interfaces + +**Requirement Name:** SEC-CTL-SMO-External-1 + +**Requirement Reference:** Clause 5.1.1.2.3, Security Controls, SMO External Interfaces, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Data in transit protection with TLS on SMO External Interfaces + +**Threat References:** T-SMO-09 + +**DUT/s:** SMO + +**Test Name:** TC\_SMO\_TLS\_External\_Interfaces + +**Purpose:** To verify the SMO supports TLS on SMO External Interface. + +**Procedure and execution steps** + +**Preconditions** + +DUT shall be the SMO with TLS support enabled. + +**Execution steps** + +This test case shall follow the execution steps for TLS specified in TLS Execution steps, clause 6.3. + +**Expected results** + +SMO External Interface shall provide confidentiality and integrity protection using TLS for data in transit. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +### 17.5.2 mTLS for SMO External Interfaces + +**Requirement Name:** SEC-CTL-SMO-External-2 + +**Requirement Reference:** Clause 5.1.1.2.3, Security Controls, SMO External Interfaces, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Mutual authentication with mTLS on SMO External Interfaces + +**Threat References:** T-SMO-01, T-SMO-04 + +**DUT/s:** SMO + +**Test Name:** TC\_SMO\_mTLS\_External\_Interfaces + +**Purpose:** To verify the SMO supports mutual authentication using mTLS, with PKI and X.509 certificates for SMO External Interfaces. + +**Procedure and execution steps** + +**Preconditions** + +DUT shall be the SMO with mTLS support enabled. + +**Execution steps** + +This test case follows the execution steps for mTLS specified in mTLS Execution steps, clause 6.3. + +**Expected results** + +The SMO shall support mutual authentication of SMO Functions using mTLS for SMO External Interfaces. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +## 17.5.3 SMO Framework OAuth 2.0 Resource Owner/Server for External Interface + +**Requirement Name:** SEC-CTL-SMO-External-3 + +**Requirement Reference:** Clause 5.1.1.2.3, Security Controls, SMO External Interfaces, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** OAuth 2.0 security controls for SMO to authorize service requests from external systems + +**Threat References:** T-SMO-02, T-SMO-05 + +**DUT/s:** SMO + +**Test Name:** TC\_SMO\_OAuth2.0\_Resource\_Owner\_Server\_External\_Interface + +**Purpose:** To verify the SMO supports OAuth 2.0 resource owner/server for SMO External Interfaces. + +**Procedure and execution steps****Preconditions** + +DUT shall be the SMO with OAuth 2.0 support enabled. An external OAuth 2.0 Authorization Server is available and configured. + +**Execution steps** + +This test case shall follow the execution steps for OAuth2.0 specified in OAuth Execution steps, clause 6.6. + +**Expected results** + +The SMO shall be able to authorize/deny access requests received from an external system using OAuth 2.0. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +## 17.5.4 SMO Functions OAuth 2.0 Client + +**Requirement Name:** SEC-CTL-SMO-External-4 + +**Requirement Reference:** Clause 5.1.1.2.3, Security Controls, SMO External Interfaces, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** OAuth 2.0 security controls for SMO support client functionality for service requests to external systems + +**Threat References:** T-SMO-02, T-SMO-05 + +**DUT/S:** SMO + +**Test Name:** TC\_SMO\_OAuth2.0\_Client\_External\_Interface + +**Purpose:** To verify the SMO supports OAuth 2.0 client for External Interfaces. + +## Procedure and execution steps + +### Preconditions + +DUT shall be the SMO with OAuth 2.0 support enabled. An external OAuth 2.0 Authorization Server is available and configured. + +### Execution steps + +This test case follows the execution steps for OAuth2.0 specified in OAuth Execution steps, clause 6.6. + +### Expected results + +The SMO shall be able to request and be permitted/denied access to external resources using OAuth 2.0. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +## 17.6 SMO Logging + +### 17.6.1 TLS for SMO Logging Export + +**Requirement Name:** SEC-CTL-SMO-Log-1 + +**Requirement Reference:** Clause 5.1.1.2.4, Security Controls, SMO Logging, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** TLS for SMO Logging Export + +**Threat References:** T-SMO-16 + +**DUT/s:** SMO + +**Test Name:** TC\_SMO\_TLS\_Logging\_Export + +**Purpose:** To verify the SMO supports TLS for SMO logging export. + +### Procedure and execution steps + +#### Preconditions + +DUT shall be the SMO with TLS support enabled. + +#### Execution steps + +This test case shall follow the execution steps for TLS specified in TLS Execution steps, clause 6.3. + +#### Expected results + +SMO shall provide confidentiality and integrity protection for logging export. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +### 17.6.2 mTLS for SMO Logging Export + +**Requirement Name:** SEC-CTL-SMO-Log-3 + +**Requirement Reference:** Clause 5.1.1.2.4, Security Controls, SMO Logging, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** mTLS on SMO Logging Export + +**Threat References:** T-SMO-01 + +**DUT/s:** SMO + +**Test Name:** TC\_SMO\_mTLS\_Logging\_Export + +**Purpose:** To verify the SMO supports mutual authentication using mTLS, with PKI and X.509 certificates, for SMO logging export. + +**Procedure and execution steps** + +**Preconditions** + +DUT shall be the SMO with mTLS support enabled. + +**Execution steps** + +This test case follows the execution steps for mTLS specified in mTLS Execution steps, clause 6.3. + +**Expected results** + +The SMO shall support mutual authentication using mTLS for SMO logging export. + +**Expected format of evidence:** Log entries, packet captures, and screenshots. + +--- + +## 18 Security test of O-Cloud + +### 18.1 Overview + +This clause contains security tests to validate the security protection mechanism specific to O-Cloud hosting the O-RAN components/system. + +### 18.2 Void + +### 18.3 O-Cloud virtualization layer + +#### 18.3.1 Secure authentication (positive case) + +**Requirement Name:** Secure authentication to O-Cloud APIs + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-1 to REQ-SEC-OCLOUD-ISO-6, clause 5.1.8.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-VM-C-06 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Secure\_Authentication\_Positive + +**Purpose:** The purpose of this test is to ensure secure authentication to O-Cloud APIs. + +**Procedure and execution steps** + +**Preconditions** + +- O-Cloud authentication mechanism are enabled. +- Valid credentials are available for authentication. + +#### Execution steps + +1. Attempt to access O-Cloud APIs with valid authentication credentials: + - a. Send an API request with providing valid authentication credentials. + +EXAMPLE: Send an API request by executing a Kubernetes **curl** command or using a Kubernetes client using the valid API key or access token for authentication (e.g., valide kubeconfig file or service account token). + +- b. Capture the response received, including the status code and response body. +- c. Verify that the API response returns a success status code. + +#### Expected results + +The API response returns a success status code. + +### 18.3.2 Secure authentication (negative case) + +**Requirement Name:** Secure authentication to O-Cloud APIs + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-1 to REQ-SEC-OCLOUD-ISO-6, clause 5.1.8.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-VM-C-06 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Secure\_Authentication\_Negative + +**Purpose:** The purpose of this test is to intentionally validate the behaviour of the authentication mechanism when encountering invalid or unauthorized authentication credentials. + +#### Procedure and execution steps + +##### Preconditions + +O-Cloud authentication mechanism is enabled. + +#### Execution steps + +1. Attempt to access O-Cloud APIs with invalid or expired authentication credentials: + - a. Send an API request with providing invalid or expired authentication credentials. + +EXAMPLE: Send an API request by executing a Kubernetes **curl** command or using a Kubernetes client using the invalid or expired API key or access token for authentication (e.g., invalid kubeconfig file, expired service account token). + +- b. Capture the response received, including the status code and response body. +- c. Verify that the API response returns an authentication failure status code. + +#### Expected results + +The API response returns an authentication failure status code. + +### 18.3.3 Secure authorization (positive case) + +**Requirement Name:** Secure authorization for accessing O-Cloud APIs + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-1 to REQ-SEC-OCLOUD-ISO-6, clause 5.1.8.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-VM-C-06 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Secure\_Authorization\_Positive + +**Purpose:** The purpose of this test is to verify that the authorization mechanism for accessing O-Cloud APIs is functioning correctly, ensuring that entities have appropriate permissions to perform specific actions on O-Cloud resources. + +#### Procedure and execution steps + +NOTE: Entities include Applications, SMO and O-Cloud software components. + +#### Preconditions + +- Valid authentication credentials. +- O-Cloud access control system is enabled containing different levels of permissions assigned to entities. + +EXAMPLE: Access control system such as Role-Based Access Control (RBAC), Attribute-Based Access Control (ABAC). + +#### Execution steps + +1. Authenticate with valid credentials: + - a. Use valid authentication credentials to establish a connection with the O-Cloud API. +2. Send an API request with authorized permissions: + - a. Construct a valid API request to perform a specific action, +EXAMPLE: specific action includes creating a pod, updating a deployment, or deleting a service. + - b. Ensure that the requested action aligns with the entity's assigned permissions. + - c. Send the request to the O-Cloud API endpoint. +3. Validate the response: + - a. Verify that the API response returns a success status code indicating the action was successfully executed. + +#### Expected results + +The API response returns a success status code, confirming that the requested action was authorized and executed successfully. + +### 18.3.4 Secure authorization (negative case) + +**Requirement Name:** Secure authorization for accessing O-Cloud APIs + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-1 to REQ-SEC-OCLOUD-ISO-6, clause 5.1.8.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-VM-C-06 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Secure\_Authorization\_Negative + +**Purpose:** The purpose of this test is to intentionally validate the behaviour of the authorization mechanism when encountering unauthorized or invalid access attempts. + +#### Procedure and execution steps + +##### Preconditions + +- Valid authentication credentials. +- O-Cloud access control system is enabled containing different levels of permissions assigned to entities. + +EXAMPLE: Access control system such as Role-Based Access Control (RBAC), Attribute-Based Access Control (ABAC). + +##### Execution steps + +1. Authenticate with valid credentials: + - a. Use valid authentication credentials to establish a connection with the O-Cloud API. +2. Send an API request with unauthorized permissions: + - a. Construct a valid API request to perform a specific action that exceeds the entity's assigned permissions, +EXAMPLE: specific action includes creating a pod, updating a deployment, or deleting a service. + - b. Send the request to the O-Cloud API endpoint. +3. Validate the response: + - a. Verify that the API response returns a failure status code indicating the action was unauthorized. + +##### Expected results + +The API response returns a failure status code, indicating that the requested action was unauthorized. + +## 18.3.5 Validate network connections allowed by network policies + +**Requirement Name:** Isolation & secure communication between Applications + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-1 to REQ-SEC-OCLOUD-ISO-6, clause 5.1.8.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-VM-C-06 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Connection\_Allowed\_Policies + +**Purpose:** The purpose of this test is to ensure that network connections between VMs/Containers allowed by network policies are successfully established. + +#### Procedure and execution steps + +##### Preconditions + +O-Cloud with network policies is configured to allow specific VMs/Containers to VMs/Containers communication. + +#### Execution steps + +1. Deploy two VMs/Containers A and B, in different zones or with different environment. + +EXAMPLE: Zones such as namespaces in Kubernetes, environment such as labels in Kubernetes + +2. Define network policies that explicitly allow communication between the two VMs/Containers. +3. Attempt to establish a network connection from VM/Container A to VM/Container B using tools. + +EXAMPLE: tools such as curl or ping in Kubernetes + +4. Capture the response or output received. + +#### Expected results + +The network connection from VM/Container A to VM/Container B is successfully established, indicating that the network policies allow the communication between the VMs/Containers. + +### 18.3.6 Validate network connections not allowed by network policies + +**Requirement Name:** Isolation & secure communication between Applications + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-1 to REQ-SEC-OCLOUD-ISO-6, clause 5.1.8.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-VM-C-06 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Connection\_Not\_Allowed\_Policies + +**Purpose:** The purpose of this test is to ensure that network connections between VMs/Containers not allowed by network policies are blocked. + +#### Procedure and execution steps + +##### Preconditions + +O-Cloud with network policies is configured to deny specific VM/Container to VM/Container communication. + +#### Execution steps + +1. Deploy two VMs/Containers A and B, in different zones or with different environment. + +EXAMPLE: Zones such as namespaces in Kubernetes, environment such as labels in Kubernetes + +2. Define network policies that explicitly deny communication between the two VMs/Containers. +3. Attempt to establish a network connection from VM/Container A to VM/Container B using tools. + +EXAMPLE: tools such as curl or ping in Kubernetes + +4. Capture the response or output received. + +#### Expected results + +The network connection from VM/Container A to VM/Container B is blocked, indicating that the network policies correctly deny the communication between the VMs/Containers. + +### 18.3.7 Validate network connections from outside the allowed network ranges + +**Requirement Name:** Isolation & secure communication between Applications + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-1 to REQ-SEC-OCLOUD-ISO-6, clause 5.1.8.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-VM-C-01, T-VM-C-02, T-VM-C-03, T-VM-C-04, T-VM-C-05, T-VM-C-06 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Connection\_Allowed\_Outside + +**Purpose:** The purpose of this test is to ensure that network connections from IP addresses outside the allowed network ranges are denied. + +#### Procedure and execution steps + +##### Preconditions + +O-Cloud with network policies is configured to restrict access based on IP ranges. + +##### Execution steps + +1. Define network policies that restrict access to certain IP ranges. +2. Attempt to access services or VMs/Containers from IP addresses outside the allowed ranges, either through direct IP access or using service names. +3. Capture the response or output received. + +EXAMPLE: In this test case, the service name refers to the Kubernetes service object's name. The service acts as a load balancer and provides a stable DNS name that can be used to access the pods associated with it. For example, suppose you have a service named my-service that is associated with a set of pods. In the test case, you would attempt to access my-service from IP addresses outside the allowed ranges. This can be done using tools like curl or by making HTTP requests to http://my-service. + +##### Expected results + +Access attempts from outside the allowed IP ranges is denied, and the response or output indicates a connection failure. + +### 18.3.8 Exploitation of O-Cloud component vulnerabilities + +**Requirement Name:** O-Cloud hardening and secure configuration. + +**Requirement Reference:** REQ-SEC-OCLOUD-SU-1, clause 5.1.8.5.1, REQ-SEC-SYS-1, clause 5.3.6.1, REQ-SEC-O-CLOUD-ISO-7, clause 5.1.8.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-O-RAN-02, T-VM-C-01, T-VM-C-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Vulnerability\_Scanning + +**Purpose:** The purpose of this test is to identify and assess the presence of vulnerabilities in O-Cloud components and evaluate the effectiveness of their mitigation measures. + +#### Procedure and execution steps + +##### Preconditions + +- O-Cloud with various O-Cloud components deployed. + +EXAMPLE: in the context of Kubernetes, components include etcd, kubelet + +- O-Cloud with security best practices is implemented. + +#### Execution steps + +1. Identify known vulnerabilities specific to the versions of used O-Cloud components using vulnerability scanning tools. +2. If known vulnerabilities exist, follow publicly available exploit scenarios or utilize penetration testing tools to attempt exploitation. +3. Monitor the O-Cloud and capture any signs of successful exploitation or vulnerabilities being triggered. + +#### Expected results + +For step 1), no known vulnerabilities exist in the O-Cloud + +For step 2), mitigation measures, such as applying security patches or configuration changes are implemented to address known vulnerabilities. + +For step 3), Exploit attempts fails to compromise the O-Cloud. + +## 18.3.9 Identification and remediation of insecure configuration settings + +**Requirement Name:** O-Cloud hardening and secure configuration + +**Requirement Reference:** REQ-SEC-OCLOUD-SU-1, clause 5.1.8.5.1, REQ-SEC-SYS-1, Clause 5.3.6.1 REQ-SEC-OCLOUD-ISO-7, Clause 5.1.8.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Threat References:** T-O-RAN-02, T-VM-C-01, T-VM-C-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Insecure\_Configuration + +**Purpose:** The purpose of this test is to identify insecure configuration settings in the O-Cloud and verify the effectiveness of remediation measures. + +#### Procedure and execution steps + +##### Preconditions + +O-Cloud with a configuration review and hardening process in place. + +##### Execution steps + +1. Review the O-Cloud configuration for common security misconfigurations, such as weak authentication settings, insecure defaults, or unencrypted communication. +2. Identify and simulate scenarios where insecure configurations can be exploited. +3. Monitor the O-Cloud and capture any signs of insecure configurations being successfully exploited. + +#### Expected results + +- The O-Cloud configuration is hardened and securely configured to mitigate common security misconfigurations. +- Insecure scenarios are identified and remediated, ensuring a hardened O-Cloud. If insecure scenarios are rectified, testing has to be repeated. + +## 18.3.10 Validation of logging and monitoring for security incidents + +**Requirement Name:** logging and monitoring for security incidents + +**Requirement Reference:** REQ-SEC-OCLOUD-O2dms-4, clause 5.1.8.9.1.1 REQ-SEC-OCLOUD-O2ims-4, clause 5.1.8.9.1.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-GEN-01, T-GEN-02, T-GEN-03, T-GEN-04, T-GEN-05, T-GEN-06 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Security\_Logs + +**Purpose:** The purpose of this test is to validate logging and monitoring for security incidents. + +**Procedure and execution steps** + +**Preconditions** + +O-Cloud with centralized logging and monitoring systems is implemented. + +**Execution steps** + +1. Simulate security incidents such as unauthorized access attempts or Application compromise: + - Attempt to perform unauthorized API requests or access o-Cloud resources without appropriate permissions. + - Mimic a compromised Application by running malicious code or attempting privilege escalation. + - Monitor the O-Cloud and capture any signs of security incidents being logged or detected. +2. Monitor the O-Cloud for detection and alerting of security events: + - Configure the logging and monitoring systems to capture relevant security events, such as failed authentication attempts, privilege escalation, or anomalous Application behaviour. + - Monitor the O-Cloud in real-time or periodically to detect the simulated security incidents. + - Verify that the monitoring system generates alerts or notifications for detected security events. + +**Expected results** + +- For the first step, unauthorized access attempts and Application compromise attempts are captured as security events in the logs. +- For the second step, the monitoring system detects and generates alerts for the simulated security incidents. + +## 18.3.11 O-Cloud Privilege Escalation Prevention + +**Requirement Name:** O-Cloud privilege escalation prevention + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-1, REQ-SEC-OCLOUD-ISO-3, clause 5.1.8.4.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-VM-C-01 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Privilege\_Escalation\_Prevention + +**Purpose:** To verify that privilege escalation is effectively prevented in O-Cloud by enforcing security policies (EXAMPLE: PodSecurity admission (PSA)). + +**Procedure and execution steps** + +**Preconditions:** + +- O-Cloud with security policies (EXAMPLE: Kubernetes cluster with PodSecurity admission (PSA)) configured and enforced. + +**Execution steps:** + +1. Attempt to create a VM or Container that attempts to escalate privileges + +EXAMPLE: in Kubernetes by specifying the **hostPID: true** or **hostNetwork: true** field in the pod's security context. + +2. Monitor the API server response and logs + +**Expected results:** + +- For step 1: The VM or Container creation request is denied by the O-Cloud API server. +- For step 2: The O-Cloud API server logs should show a message indicating a violation of the security policies. + +**Expected format of evidence:** + +- Screenshot: Displaying the API server's response to the VM or Container creation attempt. +- Executed Commands: Details of the VM or Container creation parameters and security context used. +- API Server Logs: Messages indicating a violation of security policies. +- Conclusion Logs: Indicating whether the test passed or failed based on expected results. + +## 18.3.12 O-Cloud mutual authentication + +**Requirement Name:** O-Cloud mutual authentication between applications + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-2, clause 5.1.8.4.2, SEC-CTL-O-CLOUD-ISO-2, clause 5.1.8.4.3, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-GEN-04 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCLOUD\_MUTUAL\_AUTHENTICATION + +**Purpose:** To verify that communication between different applications running on the O-Cloud is secured through mutual TLS (mTLS) authentication. + +**Procedure and execution steps** + +**Preconditions:** + +- Environment: An O-Cloud is set up with two or more deployed applications +EXAMPLE: A cluster with two applications, each running in separate pods. +- mTLS configuration: Deployed applications in the O-Cloud are configured with mTLS as defined in [2] clause 4.2. +- Tools setup: Network sniffers, packet capture and TLS inspection tools are deployed to monitor and verify TLS handshake process. + +- Valid, expired, and revoked certificates are prepared for testing. Ensure that the infrastructure for checking revoked certificates (CRL/OCSP server) is operational and accessible to the applications. + +#### Execution steps: + +- Initiate mTLS-secured sessions between applications and capture the TLS handshake process. + - Validate the exchange and authentication of certificates using TLS inspection tools. +- Attempt connections using valid certificates and record the outcomes. + - Attempt connections using expired certificates and record the outcomes. + - Attempt connections, confirm that applications recognize the certificates as revoked (evidenced by querying the CRL or OCSP server), and record outcomes. + - Attempt to establish an unauthenticated session (no certificate presented) and record the outcome. + +#### Expected results: + +- mTLS sessions are successfully established only with valid certificates. +- mTLS session establishment with expired certificates fails. +- mTLS session establishment with revoked certificates fails. +- Any attempt to initiate an unauthenticated session (without presenting a certificate) is rejected. + +#### Expected format of evidence: + +Logs from network sniffers, packet captures and TLS inspection tools showing: + +- Successful mTLS handshakes with valid certificates. +- Rejections due to expired certificates, ensuring the application appropriately identifies and handles certificates beyond their validity period. +- Rejections due to revoked certificates, with specific emphasis on the application's process for recognizing revoked certificates through mechanisms such as CRL (Certificate Revocation List) and OCSP (Online Certificate Status Protocol) queries. +- Rejection of unauthenticated sessions, demonstrating the system's enforcement of mTLS authentication by not allowing sessions without certificate authentication. + +## 18.3.13 O-Cloud authorization + +**Requirement Name:** O-Cloud authorization + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-2, clause 5.1.8.4.2, SEC-CTL-O-CLOUD-ISO-3, clause 5.1.8.4.3, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-GEN-04 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCLOUD\_AUTHORIZATION + +**Purpose:** To verify that authorization policies are correctly enforced according to the least privilege principle. + +**Procedure and execution steps** + +#### Preconditions: + +- Environment: An O-Cloud is set up with two or more applications + +EXAMPLE: A cluster with two applications, each running in separate pods. + +- Access control configuration: Access control policies are defined and applied to applications, ensuring permissions are scoped to the minimum necessary privileges. +- Tools setup: auditing tools are deployed to monitor and verify access control policies. + +EXAMPLE: Kubernetes audit logs for access control verification. + +#### Execution steps: + +- Map out the actions each application can perform on another according to the access control policies. + - EXAMPLE: using ‘kubectl describe role’ and ‘kubectl describe rolebinding’ to detail the actions each application is permitted to perform on another under the access control policies. +- 1. Perform an action that is allowed by the access control policy and record the outcomes. Validate that permitted actions align with the mapped policies. + - EXAMPLE: using ‘kubectl auth can-i’ to validate that the action is permitted. +- 2. Attempt actions that are not permitted by the access control policies and record the outcomes. + - EXAMPLE: using ‘kubectl auth can-i’ to confirm that actions beyond the scope of granted permissions are denied. + +#### Expected results: + +1. All actions that are explicitly granted by the access control policies are successfully performed without errors. Audit logs reflect the correct enforcement of these policies. +2. Any attempts to perform actions outside the scope of granted permissions are denied, with audit logs accurately recording these access denials in accordance with the access control policies. + +EXAMPLE: Monitor Kubernetes audit logs to capture policy decisions, noting both allowed and denied actions. + +#### Expected format of evidence: + +Detailed logs capturing: + +1. Allowed actions, correlating with the defined access control policies. +2. Denied actions, specifically those attempted outside the granted permissions, highlighting the effective enforcement of access control policies. + +## 18.4 Application deployment by O-Cloud + +### 18.4.1 Verification of Application artifacts with valid signature by O-Cloud during deployment + +**Requirement Name:** Verification of Application artifacts by O-Cloud during deployment + +**Requirement Reference:** REQ-SEC-OCLOUD-PKG-2, clause 5.1.8.2.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-IMG-01, T-IMG-04, T-AppLCM-02 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Valid\_Signature\_Verification\_During\_Deployment + +**Purpose:** To verify the O-Cloud ability to check the cryptographic signature of an Application artifact during the process of deployment, ensuring the integrity of Applications deployed in the O-Cloud when the signature is valid. + +#### Procedure and execution steps + +##### Preconditions: + +- O-Cloud configured to enforce artifact verification. +- Valid Application artifact with associated signatures. +- The Solution provider certificate (used to sign the Application artifact) is issued by a CA trusted by the Service provider, and the root certificate of the CA is pre-installed at O-Cloud. + +##### Execution steps: + +- a. Try creating a VM or Container (EXAMPLE: Kubernetes Pod) specification using the valid Application artifact and deploy the VM or Container. +- b. Monitor the O-Cloud logs (EXAMPLE: Kubelet logs) for any signature verification events related to the deployment. +- c. Verify that the O-Cloud (EXAMPLE: Kubelet) successfully verifies the cryptographic signature of the Application artifact. + +##### Expected results: + +- a. Logs show entries related to the signature verification, and the O-Cloud successfully verifies the cryptographic signature of the application artifact. +- b. The VM or Container is successfully created and deployed without issues. + +##### Expected format of evidence: + +- Screenshot: Displaying the O-Cloud's response to the VM or Container deployment attempt, including the signature verification result. +- Executed Commands: Details of the VM or Container creation parameters, including the Application artifact and its cryptographic signature. +- O-Cloud Logs: Messages indicating signature verification events related to the deployment.. + +## 18.4.2 Verification of Application artifacts with incorrect signature by O-Cloud during deployment + +**Requirement Name:** Verification of Application artifacts by O-Cloud during deployment + +**Requirement Reference:** REQ-SEC-OCLOUD-PKG-2, clause 5.1.8.2.1, O-RAN Security Requirements and Controls Specifications [5] + +##### Requirement Description: + +**Threat References:** T-IMG-01, T-IMG-04, T-AppLCM-02 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Incorrect\_Signature\_Verification\_During\_Deployment + +**Purpose:** To verify the O-Cloud ability to detect and reject an incorrect cryptographic signature of an Application artifact during deployment, ensuring the integrity of Applications deployed in the O-Cloud when the signature is invalid. + +#### Procedure and execution steps + +##### Preconditions: + +- O-Cloud configured to enforce artifact verification. +- Application artifact with an incorrect associated signature. +- The Solution provider certificate (used to sign the Application artifact) is issued by a CA trusted by the Service provider, and the root certificate of the CA is not pre-installed at O-Cloud. + +**Execution steps:** + +- Try creating a VM or Container (EXAMPLE: Kubernetes Pod) specification using the artifact with an incorrect signature and deploy the VM or Container. +- Monitor the O-Cloud logs (EXAMPLE: Kubelet logs) for any signature verification events related to the deployment. +- Verify that the O-Cloud (EXAMPLE: Kubelet) detects the incorrect cryptographic signature and denies the deployment of the VM or Container. + +**Expected results:** + +Logs show entries related to the signature verification , and the O-Cloud detects the incorrect cryptographic signature, denying the VM or Container deployment. + +**Expected format of evidence:** + +- Screenshot: Displaying the O-Cloud's response to the VM or Container deployment attempt, including the denial due to the incorrect cryptographic signature. +- Executed Commands: Details of the VM or Container creation parameters, including the Application artifact and its cryptographic signature. +- O-Cloud Logs: Messages indicating failed signature verification events related to the deployment. + +## 18.5 Resource Management and enforcement in O-Cloud + +### 18.5.1 O-Cloud Resource Consumption Limit Enforcement + +**Requirement Name:** Resource Management and enforcement in O-Cloud + +**Requirement Reference:** REQ-SEC-LCM-SD-1 to REQ-SEC-LCM-SD-4, clause 5.3.2.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-VM-C-05, T-AppLCM-04, T-AppLCM-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Resource\_Consumption\_Limit\_Enforcement + +**Purpose:** To verify the DUT is able to ensure that resources (CPU, memory, etc.) consumed by VMs or Containers are within the defined limits, preventing any single application from monopolizing the system's resources. + +**Procedure and execution steps** +**Preconditions:** + +- O-Cloud environment with resource quotas and limits enforced. +- A configured SMO to set and enforce resource quotas and limits. + +**Execution steps:** + +- Set up resource quotas and limit ranges:** + - Create a dedicated isolated environment for testing. + +- Define a resource quota for the environment, specifying the maximum allowed CPU and memory. +- Define a limit range to set default request and limit values for resources. +- 2. **Attempt to deploy a VM or Container that requests resources beyond the defined limits:** + - Create a VM or Container configuration that requests resources exceeding the set limits. + - Try to deploy the VM or Container in the test environment. +- 3. **Monitor the deployment status and logs:** + - Check the deployment status of the VM or Container. + +#### Expected results: + +- For step 1: Confirmation that a dedicated isolated environment for testing has been setup and both resource quota and limit range have been established. +- For step 2: The deployment request for the VM or Container is denied or remains in a "Pending" or equivalent state. +- For step 3: Logs or descriptions should show a message indicating a violation of the resource quotas or limits. + +#### Expected format of evidence: + +- Configuration Details: Information on the set resource quotas and limit ranges, including the maximum allowed CPU and memory. +- Executed Commands: Details of the VM or Container creation parameters, specifically the requested resources. +- O-Cloud Logs: Messages indicating any violations of the resource quotas or limits during the deployment attempt. +- Deployment Status: Logs or screenshots showing the status of the VM or Container deployment, especially if it's denied or remains in a "Pending" state due to resource constraints. + +#### EXAMPLE using Kubernetes: + +1. **Set up resource quotas and limit ranges in Kubernetes:** + - Create a namespace: **kubectl create namespace test-limits** + - Apply a ResourceQuota and LimitRange as previously detailed. +2. **Attempt to deploy a Pod in Kubernetes:** + - Create a pod configuration (**resource-hog-pod.yaml**) that requests excessive resources. + - Deploy using: **kubectl apply -f resource-hog-pod.yaml** +3. **Monitor the deployment status and logs in Kubernetes:** + - Check pod status: **kubectl get pods -n test-limits** + - Describe the pod for details: **kubectl describe pod resource-hog -n test-limits** + +## 18.5.2 O-Cloud Storage Volume Limit Enforcement + +**Requirement Name:** Resource Management and enforcement in O-Cloud + +**Requirement Reference:** REQ-SEC-LCM-SD-1 to REQ-SEC-LCM-SD-4, clause 5.3.2.3.1 , O-RAN Security Requirements and Controls Specifications [5] + +#### Requirement Description: + +**Threat References:** T-VM-C-05, T-AppLCM-04, T-AppLCM-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Storage\_Volume\_Limit\_Enforcement + +**Purpose:** To verify the DUT is able to limit the storage volume allocations for applications predefined in a O-Cloud environment. + +#### Procedure and execution steps: + +#### Preconditions: + +- O-Cloud environment with storage volume configurations. + +- A configured SMO to set and enforce resource quotas for storage. + +#### Execution steps: + +1. **Set up Storage Volume Quotas:** + - Create a dedicated isolated environment for testing. + - Define a storage volume quota for the environment, specifying the maximum allowed storage volume size. +2. **Attempt to allocate a storage volume beyond the defined limits:** + - Create a configuration that requests a storage volume size exceeding the set limits. + - Deploy the configuration in the test environment. +3. **Monitor the storage allocation status and logs:** + - Check the status of the storage allocation. + +#### Expected results: + +- For step 1: Confirmation that a dedicated isolated environment for testing has been setup and storage volume quota has been defined. +- For step 2: The storage volume allocation request is denied. +- For step 3: Logs or descriptions should show a message indicating a violation of the storage quotas. + +#### Expected format of evidence: + +- Configuration Details: Information on the set storage volume quotas, including the maximum allowed storage volume size. +- Executed Commands: Details of the storage volume allocation parameters, specifically the requested storage size. +- O-Cloud Logs: Messages indicating any violations of the storage volume quotas during the allocation attempt. +- Allocation Status: Logs or screenshots showing the status of the storage volume allocation, especially if it is denied due to exceeding the set limits. + +#### EXAMPLE using Kubernetes: + +- Create a namespace: `kubectl create namespace test-storage` +- Apply a ResourceQuota for storage: + +``` +apiVersion: v1 +kind: ResourceQuota +metadata: + name: storage-quota + namespace: test-storage +spec: + hard: + requests.storage: 10Gi +``` +- Apply the ResourceQuota: `kubectl apply -f storage-quota.yaml` +- Create and deploy a PersistentVolumeClaim (PVC) requesting 15Gi. +- Monitor the PVC status and logs. + +## 18.5.3 O-Cloud CPU Overcommit Prevention + +**Requirement Name:** Resource Management and enforcement in O-Cloud + +**Requirement Reference:** REQ-SEC-LCM-SD-1 to REQ-SEC-LCM-SD-4, clause 5.3.2.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-VM-C-05, T-AppLCM-04, T-AppLCM-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_CPU\_Overcommit\_Prevention + +**Purpose:** To verify that the O-Cloud does not overcommit CPU resources, leading to performance degradation or system instability. + +### Procedure and execution steps + +#### Preconditions: + +- O-Cloud with CPU allocation settings. +- A configured SMO to manage CPU overcommitment. + +#### Execution steps: + +##### 1. Set CPU Overcommit Ratios: + +- Create a dedicated isolated environment for testing. +- Define CPU overcommit ratios. + +##### 2. Attempt to deploy multiple applications: + +- Sequentially deploy applications until the CPU limits are reached based on the overcommit ratios. +- Monitor the CPU utilization of each deployed application. + +##### 3. Monitor the deployment status and CPU utilization metrics: + +- Check the deployment status of the applications. +- Monitor CPU utilization metrics. + +#### Expected results: + +- For step 1: Confirmation that a dedicated isolated environment for testing has been setup and CPU overcommit ratios has been defined. +- For step 2: Applications should not be deployed beyond the capacity determined by the CPU overcommit ratios. +- For step 3: CPU utilization metrics should remain stable and within acceptable thresholds. + +#### Expected format of evidence: + +- Configuration Details: Information on the set CPU overcommit ratios. +- Executed Commands: Details of the application deployments and their respective CPU utilization. +- O-Cloud Logs: Messages indicating any violations of the CPU overcommit ratios during application deployments. +- Deployment Status: Logs or screenshots showing the status of the application deployments, especially if any are denied due to reaching CPU limits. +- CPU Utilization Metrics: Graphs or logs showing the CPU utilization of each deployed application, ensuring they remain within acceptable thresholds. + +EXAMPLE using Kubernetes: + +##### 1. Set CPU Overcommit Ratios: + +- Manage CPU overcommitment in Kubernetes by setting CPU requests and limits on Pods. + +##### 2. Attempt to deploy multiple applications: + +- Deploy a Pod with a CPU request of '**500m**' (half a CPU core) and a limit of '**1**' (one full CPU core). + +##### 3. Monitor the deployment status and CPU utilization metrics: + +- Use '**kubect**l describe node ' to view CPU allocation and utilization. +- Monitor CPU metrics using tools like Prometheus. + +## 18.5.4 O-Cloud Memory Overcommit Prevention + +**Requirement Name:** Resource Management and enforcement in O-Cloud + +**Requirement Reference:** REQ-SEC-LCM-SD-1 to REQ-SEC-LCM-SD-4, clause 5.3.2.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-VM-C-05, T-AppLCM-04, T-AppLCM-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Memory\_Overcommit\_Prevention + +**Purpose:** To verify that the O-Cloud does not overcommit memory resources. + +**Procedure and execution steps** + +**Preconditions:** + +- O-Cloud with memory allocation settings. +- A configured SMO to manage memory overcommitment + +**Execution steps:** + +**1. Set Memory Overcommit Ratios:** + +- Create a dedicated isolated environment for testing. +- Define memory overcommit ratios. + +**2. Attempt to deploy applications:** + +- Sequentially deploy applications until memory limits are reached based on the overcommit ratios. +- Monitor memory utilization of each deployed application. + +**3. Monitor deployment status and memory utilization metrics:** + +- Check deployment status of the applications. +- Monitor memory utilization metrics. + +**Expected results:** + +- For step 1: Confirmation that a dedicated isolated environment for testing has been setup and memory overcommit ratios has been defined. +- For step 2: Applications should not be deployed beyond the capacity determined by the memory overcommit ratios. +- For step 3: Memory utilization should remain stable and within acceptable thresholds. + +**Expected format of evidence:** + +- Configuration Details: Information on the set memory overcommit ratios. +- Executed Commands: Details of the application deployments and their respective memory use. +- O-Cloud Logs: Messages indicating any violations of the memory overcommit ratios during application deployments. +- Deployment Status: Logs or screenshots showing the status of the application deployments, especially if any are denied due to reaching memory limits. +- Memory Use Metrics: Graphs or logs showing the memory utilization of each deployed application, ensuring they remain within acceptable thresholds. + +EXAMPLE using Kubernetes: + +**1. Set Memory Overcommit Ratios:** + +- Manage memory overcommitment in Kubernetes by setting memory requests and limits on Pods. + +**2. Attempt to deploy applications:** + +- Deploy a Pod with a memory request of '256Mi' and a limit of '512Mi'. + +**3. Monitor deployment status and memory utilization metrics:** + +- Use **kubect**l describe node to view memory allocation and utilization. +- Monitor memory metrics using tools like Prometheus. + +## 18.5.5 O-Cloud Network Overcommit Prevention + +**Requirement Name:** Resource Management and enforcement in O-Cloud + +**Requirement Reference:** REQ-SEC-OCLOUD-ISO-6, clause 5.1.8.4.2 REQ-SEC-LCM-SD-1 to REQ-SEC-LCM-SD-4, clause 5.3.2.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-VM-C-05, T-AppLCM-04, T-AppLCM-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Network\_Overcommit\_Prevention + +**Purpose:** To verify that the O-Cloud environment does not overcommit network bandwidth. + +### Procedure and execution steps + +#### Preconditions: + +- O-Cloud environment with network configurations. +- Tools to manage network overcommitment. + +#### Execution steps: + +##### 1. Set Network Overcommit Ratios: + +- Define network bandwidth overcommit ratios. + +##### 2. Attempt to utilize network bandwidth: + +- Deploy applications designed to generate high network traffic. +- Monitor network traffic. + +##### 3. Monitor network traffic metrics: + +- Check network traffic metrics for the applications. + +#### Expected results: + +- For step 1: Confirmation that network bandwidth overcommit ratios has been defined. +- For steps 2 and 3: Applications' network traffic should be throttled or limited once the bandwidth determined by the overcommit ratios is reached. + +#### Expected format of evidence: + +- Configuration Details: Information on the set network bandwidth overcommit ratios. +- Executed Commands: Details of the application deployments and their respective network traffic generation. +- O-Cloud Logs: Messages indicating any violations of the network overcommit ratios during high network traffic. +- Deployment Status: Logs or screenshots showing the status of the application deployments, especially if network traffic is throttled or limited. +- Network Traffic Metrics: Graphs or logs showing the network traffic of each deployed application, ensuring they remain within the set bandwidth limits. + +EXAMPLE using Kubernetes: + +##### 1. Set Network Overcommit Ratios: + +- Native Kubernetes doesn't offer direct network bandwidth controls. However, third-party plugins like 'Calico' or 'Cilium' can be used to set network policies that limit bandwidth. + +##### 2. Attempt to utilize network bandwidth: + +- Deploy a Pod and apply a network policy that limits its bandwidth. + +### 3. Monitor network traffic metrics: + +- Use monitoring tools integrated with the network plugin (e.g., ‘calicoctl’ for Calico) to observe the network traffic metrics. + +## 18.5.6 O-Cloud Storage Overcommit Prevention + +**Requirement Name:** Resource Management and enforcement in O-Cloud + +**Requirement Reference:** REQ-SEC-LCM-SD-1 to REQ-SEC-LCM-SD-4, clause 5.3.2.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-VM-C-05, T-AppLCM-04, T-AppLCM-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Storage\_Overcommit\_Prevention + +**Purpose:** To verify that the O-Cloud does not overcommit storage resources. + +### Procedure and execution steps + +#### Preconditions: + +- O-Cloud environment with storage configurations. +- A configured SMO to manage Storage overcommitment. + +#### Execution steps: + +1. Set Storage Overcommit Ratios: + - Define storage overcommit ratios. +2. Attempt to allocate storage beyond defined limits: + - Deploy applications that request storage space. + - Monitor storage allocation and utilization. +3. Monitor storage allocation and utilization metrics: + - Check storage metrics for the applications. + +#### Expected results: + +- For step 1: Confirmation that storage overcommit ratios has been defined. +- For step 2: Storage allocations should not exceed the capacity determined by the storage overcommit ratios. +- For step 3: Storage usage should remain stable and within acceptable thresholds. + +#### Expected format of evidence: + +- Configuration Details: Information on the set storage overcommit ratios. +- Executed Commands: Details of the application deployments and their respective storage requests. +- O-Cloud Logs: Messages indicating any violations of the storage overcommit ratios during storage allocation. + +- Deployment Status: Logs or screenshots showing the status of the application deployments, especially if storage allocations are denied or limited. +- Storage usage Metrics: Graphs or logs showing the storage utilization of each deployed application, ensuring they remain within the set storage limits. + +EXAMPLE using Kubernetes: + +### 1. Set Storage Overcommit Ratios: + +- Use PersistentVolumeClaims (PVCs) with specific storage requests. Overcommitment can occur if the total storage requested by PVCs exceeds the actual available storage. + +### 2. Attempt to allocate storage beyond defined limits: + +- Deploy a Pod that uses a PVC requesting more storage than available on the PersistentVolume (PV). + +### 3. Monitor storage allocation and utilization metrics: + +- Use 'kubectrl get pvc' and 'kubectrl get pv' to monitor storage allocations. +- Monitor storage metrics using tools like Prometheus. + +NOTE: Below are the general guidelines to ensure effective monitoring across all test cases: + +1. Immediate Feedback Expectation: Upon executing any test case, especially those involving security or resource constraints, immediate feedback is typically anticipated. This feedback can be in the form of API responses, system alerts, or log entries. +2. Monitoring Duration: While immediate feedback is expected, it's recommended to monitor for an additional 1-3 minutes post-execution to capture any delayed logs, alerts, or system responses. This ensures that asynchronous events or alerts are not missed. +3. Tools and Logs: Use appropriate monitoring tools, logging systems, or commands (e.g., In Kubernetes like kubectrl describe or kubectrl logs) to gain insights into the test execution. Ensure that these tools are set up in advance and are accessible to the testing team. + +## 18.6 Secure Update + +### 18.6.1 O-Cloud Infrastructure Software Package Integrity - Positive + +**Requirement Name:** O-Cloud software images authenticity and Integrity + +**Requirement Reference:** SEC-CTL-ALM-PKG-1B, clause 5.3.2.1.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Ensure Authenticity and Integrity of O-Cloud Software Images + +**Threat References:** T-GEN-01 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Software\_Package\_Integrity + +**Purpose:** To verify the O-Cloud software image authenticity and integrity. + +**Procedure and execution steps** + +**Preconditions** + +- Signed O-Cloud software package as per Clause 5 of O-RAN Security Protocols Specifications [2] + +- All necessary artifacts of the O-Cloud software image (public key, digitally signed certificates, signature (Signed hash) encryption key if any for security-sensitive artifacts) are provided. + +EXAMPLE: O-Cloud software includes AAL drivers, IMS, DMS, Host OS, Hypervisor, Container Engine. + +### Execution steps + +1. The Tester is properly authenticated and have the required access privileges to perform the test activity. +2. The tester shall verify the authenticity and integrity of the list of images. The O-Cloud software package shall be verified with the provided X.509 certificate and signature provided by the O-Cloud Software Provider. The cryptographic hash of the software image is calculated and verified against the hash in the signature by the Software Provider. +3. On successful validation of O-Cloud software images in Step 2, the Service Provider shall sign the verified O-cloud software image with its private key and onboard it to the SMO. +4. The newly signed O-Cloud images shall be onboarded to the O-cloud Image Repository. +5. The tester shall verify the digital signature of the O-Cloud software image bundle provided by the Software and Service Provider before deployment. +6. Monitor the SMO logs for signature verification events related to the upgrade. +7. Monitor the O-Cloud logs for any signature verification events related to the upgrade. + +### Expected results + +Logs show that the software package integrity check has been executed for the O-Cloud software at each stage + +The signature validation for the O-Cloud software image during onboarding are checked and is successful. + +### Expected format of evidence: + +Snapshots captured in SMO logs regarding the Signature verification success. + +Logs from SMO and O-Cloud (O2ims logs) to indicate the successful signature verification from the Software Provider. + +## 18.6.2 O-Cloud Infrastructure Software Package Integrity Failure – Negative + +**Requirement Name:** O-Cloud software images authenticity and Integrity + +**Requirement Reference:** SEC-CTL-ALM-PKG-1B, clause 5.3.2.1.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Ensure Authenticity and Integrity of O-Cloud Software Images + +**Threat References:** T-GEN-01 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCloud\_Software\_Package\_Integrity\_Failure + +**Purpose:** To verify the O-Cloud software image authenticity and integrity validation failure for invalid O-cloud software image. + +### Procedure and execution steps + +#### Preconditions + +- O-Cloud software package obtained from the Software Provider. + +- All necessary artifacts of the O-Cloud software image (public key, digitally signed certificates, Signature (signed hash) encryption key if any for security-sensitive artifacts) are provided. + +EXAMPLE: O-Cloud software includes AAL drivers, IMS, DMS, Host OS, Hypervisor, Container Engine. + +### Execution steps + +1. The Tester is properly authenticated and has the required access privileges to perform the upgrade activity. +2. Attempt to validate the O-Cloud Software with the wrong public key. +3. Verify that the SMO detects the incorrect cryptographic signature and does not allow onboarding of the software package. +4. Monitor the SMO logs for any signature verification events related to the software integrity check. + +### Expected results + +Logs show that the software package integrity check has failed. + +The O-cloud software image shall not be onboarded due to the software integrity failure. + +### Expected format of evidence: + +Snapshots captured in SMO regarding the signature verification failure. + +SMO Logs: Onboarding failure logs to indicate that integrity failure for the O-Cloud software Package. + +## 18.6.3 Secure Update procedure for O-Cloud Platform – Positive + +**Requirement Name:** Secure update of O-Cloud software at the infrastructure level layer. + +**Requirement Reference:** SEC-CTL-ALM-PKG-1B, clause 5.3.2.1.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Ensure secure update of O-Cloud Software Images at the Infrastructure level. + +**Threat References:** T-GEN-01 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_SECURE\_UPDATE\_OF\_O-CLOUD\_PLATFORM + +**Purpose:** To verify the secure update procedure for the O-Cloud Infrastructure using verified O-cloud software image. + +### Procedure and execution steps + +#### Preconditions + +- Verified O-Cloud software package obtained from Service Provider. +- All necessary artifacts of the O-Cloud software image (public key, digitally signed certificates, encryption key if any for security-sensitive artifacts) shall be provided. +- All necessary documents related to the Upgrade procedure of the O-Cloud components shall be available. +- All necessary dependencies for O-Cloud software packages are considered prior to update. +- All documents related to backward compatibility are made available by the O-Cloud Software provider. + +EXAMPLE: O-Cloud software includes AAL drivers, IMS, DMS, Host OS, Hypervisor, Container Engine. + +**Execution steps** + +1. The Tester is properly authenticated and has the required access privileges to perform the upgrade activity. +2. The O-Cloud Platform to ensure image verification. +3. The tester performs all the necessary pre-upgrade steps on the O-Cloud Platform to ensure successful update. + +EXAMPLE: + +- a. Back up any important components, such as app-level state stored in a database, or state of critical nodes. +EXAMPLE: Snapshots, Clones + +4. As per the Upgrade documentation, the tester shall perform the upgrade of the O-Cloud Platform components. + +EXAMPLE: + +- a. Phased upgrades for service availability. + - b. Stage the Upgrade procedure: upgrade control plane nodes and upgrade the worker nodes. +5. Monitor the O-Cloud logs (EXAMPLE: O2ims logs) for the update steps performed on the platform. + 6. Perform a Post-Update Audit to verify the status of the O-Cloud Platform. + 7. Verify in the SMO that the software version for the O-Cloud platform components is updated to the required version. + +**Expected results** + +The version of the O-Cloud software components is updated to the required version. + +EXAMPLE: AAL driver version, IMS version, DMS version, Host OS version, Hypervisor, Container Engine. + +**Expected format of evidence:** + +O-Cloud logs: Log captures indicating the Steps performed during the Update. + +Snapshot: Executed command on CLI, GUI, API server + +SMO Log: Notification on the successful upgrade of the O-Cloud components. + +## 18.6.4 Secure Update failure for O-Cloud Platform – Negative + +**Requirement Name:** Rollback to the previous version on the unsuccessful update of the O-Cloud Platform. + +**Requirement Reference:** SEC-CTL-ALM-PKG-1B, clause 5.3.2.1.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** The O-Cloud platform maintains its initial state if updates fail or incidents occur during update. + +**Threat References:** T-GEN-01 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_SECURE\_UPDATE\_FAILURE\_OF\_O-CLOUD\_PLATFORM + +**Purpose:** To verify on failure of secure Update procedure for the O-Cloud platform, it shall remain in its initial working state. + +**Procedure and execution steps** + +**Preconditions** + +- Verified O-Cloud platform software package obtained from Service Provider. +- All necessary artifacts of the O-Cloud platform software image (public key, digitally signed certificates, encryption key if any for security-sensitive artifacts) shall be provided. +- All necessary documents related to the Upgrade procedure of the O-Cloud components are made available. + +EXAMPLE: O-Cloud software includes AAL drivers, IMS, DMS, Host OS, Hypervisor, Container Engine. + +**Execution steps** + +1. The Tester is properly authenticated and have the required access privileges to perform the upgrade activity. +2. The O-Cloud Platform to ensure image verification. +3. The tester performs all the pre-upgrade steps on the O-Cloud Platform. + +EXAMPLE: + +- a. Back up any important components, such as app-level state stored in a database, state of critical nodes. +4. As per the Upgrade documentation, the tester shall stage and perform the upgrade of the O-Cloud Platform + +EXAMPLE: + +- a. Phased upgrades for service availability. + - b. Stage the Upgrade procedure: Upgrade control nodes and upgrade the worker nodes. +5. Attempt to simulate an upgrade failure scenario. EXAMPLE: Unexpected upgrade termination, Abrupt Power failure, Network disruption. + 6. Monitor the O-Cloud logs (EXAMPLE: O2ims logs) for the upgrade steps performed on the platform. + 7. Perform a Post-Update Audit to verify the status of the O-Cloud Platform. + 8. The O-Cloud Platform shall automatically roll-back to its previous version. + 9. Verify in the SMO that the software version for the O-Cloud platform components remains the same as the previous version. + +**Expected results** + +The O-Cloud Platform shall automatically roll-back to its previous version and initial working state. + +SMO logs to indicate the notification of the Update failure and the version of the O-Cloud components maintains its initial state. + +**Expected format of evidence:** + +O-Cloud and SMO logs: Log captures indicating the Steps performed during the Upgrade and the version of the O-Cloud components + +Snapshot: Executed command on CLI, GUI, API server + +## 18.7 Secure Storage + +### 18.7.1 Sensitive data protection in O-Cloud + +**Requirement Name:** Sensitive data protection in O-Cloud + +**Requirement Reference:** REQ-SEC-ALM-PKG-13, clause 5.3.2.1.1, REQ-SEC-OCLOUD-SS-1, clause 5.1.8.6.1, SEC-CTL-OCLOUD-SS-1, clause 5.1.8.6.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-GEN-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_DATA\_PROTECTION\_OCLOUD + +**Purpose:** To validate that the O-Cloud ensures the integrity and confidentiality of sensitive data at rest, in use, and in transit, using state-of-the-art encryption and security practices. + +**Procedure and execution steps:** + +**Preconditions:** + +- O-Cloud operational with a simulated deployment of workloads. + +**Execution steps:** + +1. **Data at rest:** + +- a) Store simulated sensitive data (e.g., secrets) in O-Cloud storage. +- b) Verify encryption using tools designed to check for industry-standard encryption mechanisms, focusing on confirming that data is encrypted to current security standards. + +2. **Data in use:** + +- a) Process sensitive data using an application. +- b) Identify write operations involving sensitive data + 1. Employ process monitoring tools to monitor file I/O operations and capture all write activities. + 2. Look for write operations to temporary file paths, cache directories or outside of the application secure storage. + 3. Analyse the context of write operations – are they occurring during a process that handles sensitive data? +- c) Ensure that the application does not log sensitive information + 1. Review the application's logging configuration and log output. + 2. Verify that sensitive data is either not logged or appropriately anonymized/encrypted before being logged. +- d) Check for the use of secure enclaves, if applicable. + +3. **Data in Transit:** + +- a) Initiate data transfer between O-Cloud services. + +- b) Use packet-sniffing tools to capture the data packets. +- c) Analyse the TLS encrypted data, ensuring TLS is used as specified in O-RAN Security Protocols Specifications [2], clause 4.2. + +**Expected Results:** + +1. Sensitive data in O-Cloud storage is encrypted according to current industry standards. Unauthorized access attempts are logged and denied. +2. Data processing is secure, with no plaintext data exposure in logs or disk. Secure enclaves are used where relevant. +3. All data transfers employ TLS as specified in O-RAN Security Protocols Specifications [2], clause 4.2. + +**Expected Format of Evidence:** + +1. Screenshots and logs showing encryption validation and the response to unauthorized access attempts. +2. Logs from process monitoring tools demonstrating the handling of sensitive data during processing. +3. Packet capture files confirming the data encryption in transit using TLS as specified in O-RAN Security Protocols Specifications [2], clause 4.2. + +## 18.7.2 Secure data deletion in O-Cloud + +**Requirement Name:** Secure data deletion in O-Cloud + +**Requirement Reference:** SEC-CTL-OCLOUD-SS-2, REQ-SEC-OCLOUD-SS-4, clause 5.1.8.6.1, SEC-CTL-OCLOUD-SS-2, clause 5.1.8.6.2 O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-GEN-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_DATA\_DELETION\_OCLOUD + +**Purpose:** To ensure that the O-Cloud platform securely deletes data from addressable memory locations that are no longer in use, by overwriting them with specific binary patterns. + +**Procedure and execution steps:** + +**Preconditions:** + +- O-Cloud platform operational with workloads. +- Tools for memory analysis are available. + +EXAMPLE: **dd** for Unix/Linux or **sdelete** for Windows environments + +- File recovery tools for testing data recoverability after deletion. + +EXAMPLE: **TestDisk** + +**Execution steps:** + +1. Data preparation: + - a. Create files with identifiable data patterns. + +EXAMPLE: a file filled with a repeating pattern of '1234' + +- b. Store these files in the O-Cloud platform's memory or storage system. +2. Data deletion: + - a. Delete the files using the O-Cloud platform's standard deletion process, which should invoke secure deletion process. +3. Verification of secure deletion: + - a. Inspect the memory or storage locations where the files were stored to confirm that the data has been overwritten. + - b. Search for both the original data patterns and the specific overwriting patterns (zeroes, ones, random). +4. Data recovery attempt: + - a. Use data recovery tools to attempt to retrieve the deleted files or any part of them. + - b. Assess if any of the original data or identifiable patterns can be recovered. + +**Expected Results:** + +1. Deleted data locations are overwritten with the specified binary patterns. +2. File recovery attempts are not able to reconstruct any meaningful data from these locations. + +**Expected Format of Evidence:** + +1. Logs or screenshots from memory analysis tools showing the overwriting patterns. +2. Reports from file recovery tools indicating the failure to recover any meaningful data. + +## 18.7.3 Data isolation in VM/Container reallocation + +**Requirement Name:** Data isolation in VM/Container reallocation + +**Requirement Reference:** REQ-SEC-OCLOUD-SS-3, clause 5.1.8.6.1, O-RAN Security Requirements and Controls Specifications + +**Requirement Description:** + +**Threat References:** T-GEN-05 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_DATA\_ISOLATION\_VM\_CONTAINER\_OCLOUD + +**Purpose:** To verify that the O-Cloud effectively prevents data contained in a resource (like memory or storage) from being accessible after it is de-allocated from one VM/Container and reallocated to another. + +**Procedure and execution steps:** + +**Preconditions:** + +- Set up multiple VMs/Containers within the O-Cloud. +- Tools for analyzing memory and storage content + +EXAMPLE: **hexdump**, **dd**, memory inspection tools + +**Execution steps:** + +1. Resource allocation and data storage: + - Allocate a dedicated resource (like a disk volume or memory segment) to a VM/Container. + - Store known test data in this resource. +2. Resource de-allocation & re-allocation: + - De-allocate the resource from the first VM/Container. + - Re-allocate the same resource to a different VM/Container. +3. Data accessibility check: + - Within the new VM/Container, attempt to access any residual data from the previous allocation. + - Use data analysis tools to inspect the resource for traces of the previous data. +4. Verification of data isolation: + - Confirm that no data from the first VM/Container is accessible or present in the resource after re-allocation. + +**Expected Results:** + +- No trace of the test data is found in the reallocated resource. +- The new VM/Container doesn't have access to any residual data from the previous allocation. + +**Expected Format of Evidence:** + +Logs or screenshots showing the absence of the test data in the re-allocated resource. + +## 18.8 Chain of trust + +### 18.8.1 Chain of Trust verification in static O-Cloud SW + +**Requirement Name:** Support of root of trust and integrity verification of static O-Cloud SW (Firmware and BIOS/UEFI, Bootloader, OS kernel) + +**Requirement Reference:** REQ-SEC-OCLOUD-COT-1, clause 5.1.8.7.1, SEC-CTL-OCLOUD-COT-1, clause 5.1.8.7.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-VL-02 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCLOUD\_CHAIN\_OF\_TRUST\_STATIC\_SW + +**Purpose:** To confirm the presence and proper functioning of a secure boot process and integrity verification for O-Cloud static SW (Firmware and BIOS/UEFI, Bootloader, OS kernel), using hardware-based or software-based roots of trust mechanisms. + +**Procedure and execution steps:****Preconditions:** + +- Ensure the O-Cloud is set up with all components, including hardware, operating system, virtualization layer, and any applications or services running on the O-Cloud. + +- Use tools capable of interfacing with the O-Cloud's root of trust mechanism. + +EXAMPLE: TPM management tools for hardware-based roots of trust, Keylime or any equivalent integrity verification system for automated integrity verification. + +- Access requirements: Tester needs administrative access to the O-Cloud platform to execute integrity verification commands and to collect integrity verification reports. + +#### Execution steps: + +Hardware RoT verification: + +Confirm the functionality of the root of trust mechanism in each O-Cloud node, whether it is hardware-based or an equivalent software-based solution. + +EXAMPLE: Use a Kubernetes DaemonSet to run `tpm2_pcrread` on all nodes, which verifies TPM presence and functionality by reading the PCR (Platform Configuration Registers) values. The DaemonSet collects outputs and send them for verification. + +Integrity check: + +Verify the integrity measurements against known good baselines. These measurements ensure the boot process and static O-Cloud SW integrity. + +EXAMPLE: + +- Use a securely stored baseline to obtain the expected PCR values for a known secure state of the O-Cloud static SWs. This could involve securely storing PCR values following a clean installation or using manufacturer-provided values. +- Schedule Kubernetes CronJobs to use Keylime for periodic integrity verification. Keylime agents on nodes interact with the TPM to attest the integrity measurements, comparing them against known good values stored in Keylime's verifier. + +Report collection and analysis: + +Collect integrity reports and analyse them for discrepancies or signs of tampering. + +EXAMPLE: Use Keylime's centralized reporting and alerting features to collect and analyse attestation data. Integrate Keylime with an ELK stack deployed within the Kubernetes cluster for enhanced log analysis and visualization of attestation outcomes. + +#### Expected Results: + +- All O-Cloud nodes demonstrate the presence of RoT. +- Integrity measurements align with known good baselines. + +#### Expected Format of Evidence: + +- Logs confirming RoT presence on each node. +- Logs indicating successful integrity verification against known good baselines. + +## 18.8.2 Chain of Trust verification of dynamic O-Cloud SW + +**Requirement Name:** Support of root of trust and integrity verification of dynamic O-Cloud SW (virtualization layer and workloads) + +**Requirement Reference:** REQ-SEC-OCLOUD-COT-2, clause 5.1.8.7.1, SEC-CTL-OCLOUD-COT-3, clause 5.1.8.7.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-VL-02 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCLOUD\_INTEGRITY\_VERIFICATION\_DYNAMIC\_SW + +**Purpose:** To ensure the integrity of dynamic software in the O-Cloud through continuous verification. + +**Procedure and execution steps:** + +**Preconditions:** + +- Ensure the O-Cloud is set up with all components, including hardware, operating system, virtualization layer, and any applications or services running on the O-Cloud. +- Use tools capable of interfacing with the O-Cloud's root of trust mechanism. + +EXAMPLE: TPM management tools for hardware-based roots of trust, Keylime to automate integrity measurements and attestation of dynamic software components, integrating with IMA for capturing runtime integrity measurements. + +- Access requirements: Tester needs administrative access to the O-Cloud platform to execute integrity verification commands and to collect integrity verification reports. + +**Execution steps:** + +Dynamic software verification: + +Initiate continuous integrity verification of the dynamic O-Cloud SW, including executable binaries and configuration files used by the container engine and workloads. + +EXAMPLE: Implement an IMA policy to measure container images and runtime configurations upon execution. Configure Keylime to monitor the integrity of container runtime environments and deployed containers on Kubernetes nodes. This involves setting up Keylime agents within the cluster that automatically update integrity measurements for dynamic software components and verify them against expected values. + +Attestation: + +Perform attestation of the container engine configurations and active workloads to detect any unauthorized changes or potential integrity breaches. + +EXAMPLE: Deploy Keylime agents on each O-Cloud node to periodically attest the integrity of dynamic SW components based on IMA measurements. Use Keylime to trigger attestation procedures that verify IMA logs against expected integrity measurements for containerized applications. + +Report collection and anomaly detection: + +Collect attestation reports and analyse them for any discrepancies, unauthorized changes, or signs of tampering in the container engine and workloads. + +EXAMPLE: Use Keylime's web interface or API integrated with an ELK stack for logging and monitoring attestation results. Set up alerts for any attestation failures or integrity breaches detected in dynamic software. + +**Expected Results:** + +- Dynamic software components are measured upon execution, with their integrity measurements securely recorded. + +- Integrity measurements are successfully captured and verified against known good baselines, indicating no unauthorized modifications. + +**Expected Format of Evidence:** + +- Logs attesting the integrity of dynamic software components, including any alerts generated for integrity failures. +- Reports detailing the comparison of runtime integrity measurements against known good baselines, demonstrating continuous integrity verification of dynamic O-Cloud dynamic software. + +## 18.9 Secure time synchronization for O-Cloud + +**Requirement Name:** Secure time synchronization for O-Cloud + +**Requirement Reference:** SEC-CTL-OCLOUD-TS-1, SEC-CTL-OCLOUD-TS-3, clause 5.1.8.12.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** It ensures all O-Cloud nodes exclusively connect to an authenticated time synchronization server for Time of Day (ToD) synchronization. + +**Threat Reference:** T-TS-01 + +**DUT/s:** O-Cloud + +**Test Name:** TC\_OCLOUD\_SECURE\_TIME\_SYN + +**Purpose:** To verify that all O-Cloud nodes are configured to exclusively connect to an authenticated time synchronization server for Time of Day (ToD) synchronization. + +**Procedure and execution steps****Preconditions:** + +- A list of allowed secure time synchronization servers +- Configuration of O-Cloud nodes + +**Execution steps:** + +1. Access the configuration of each O-Cloud node to review the time synchronization settings. +2. Check that each O-Cloud node is configured to only connect to one or more time synchronization servers from the list of allowed secure time synchronization servers. +3. Ensure that no other time synchronization servers are configured. +4. Confirm that the cryptographic keying material for verifying the server's authenticity is present in the configuration. + +**Expected results:** + +- Each O-Cloud node is configured to connect only to the allowed secure time synchronization server(s), and the cryptographic keying material for verifying each server's authenticity is present in the configuration. + +**Expected format of evidence:** + +- Screenshots showing the O-Cloud node configuration settings with the allowed time synchronization server(s) details. + +--- + +## 19 Security test of VNF/CNF + +### 19.1 Overview + +This clause contains security tests to validate the security protection mechanism specific to O-RAN architecture elements which are virtualized/containerized and deployed on the O-Cloud/SMO. + +### 19.2 Executive environment protection + +**Requirement Name:** secure executive environment provision + +**Requirement Reference:** REQ-SEC-LCM-SD-5, REQ-SEC-LCM-SD-6, REQ-SEC-LCM-SD-7, clause 5.3.2.3.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** It ensures all O-RAN architecture elements only consume the resources from its defined resource quotas. + +**Threat References:** T-AppLCM-04, T-AppLCM-05 + +**DUT/s:** O-CU, O-DU, Near-RT RIC, xApps, rApps + +**Test Name:** TC\_SECURE\_EXECUTIVE\_ENV\_PROVISION + +**Purpose:** + +To test whether the NFO compares the Application's owned resource state with the defined resource quotas from the Application descriptor. + +To test whether the NFO sends an alarm to the SMO if the two resource states are inconsistent. + +**Procedure and execution steps** + +**Preconditions** + +There are: Application, O-Cloud, SMO, NFO, Application Descriptor, (or simulated O-Cloud, SMO) on the test environment. + +**Execution steps** + +Execute the following steps: + +1. The tester utilizes the O-Cloud to change the resource state of Application (e.g. change vCPU size of the Application). +2. The tester uses the NFO to query the parsed resource state from the Application descriptor. +3. The tester checks whether the NFO sends an alarm to the SMO when the NFO receives the parsed resource state from the Application descriptor and finds that the owned resource state and the parsed resource state are inconsistent. + +**Expected Results** + +NFO sends an alarm to the SMO when the NFO receives the parsed resource state from the Application descriptor and find that the owned resource state and the parsed resource state are inconsistent. + +**Expected format of evidence:** + +Screenshots of logs containing the alarm on the SMO. + +## 19.3 Signature validation during App image onboarding + +**Requirement Name:** Signature validation during App image onboarding + +**Requirement Reference:** REQ-SEC-ALM-PKG-5, REQ-SEC-ALM-PKG-6, clause 5.3.2.1.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-IMG-04, T-AppLCM-01 + +**DUT/s:** O-CU, O-DU, Near-RT RIC, xApps, rApps + +**Test Name:** TC\_SIGNATURE\_VALIDATION\_DURING\_APP\_IMAGE\_ONBOARDING + +**Purpose:** The purpose of this test is to validate the digital signature verification mechanism during the onboarding process of application images into the NFO. + +### Procedure and execution steps + +#### Preconditions + +- The Application document describes information regarding digital signature protection of Application images, including details of how the signature check is carried out, who makes the digital signature of Application image etc. +- One Application package included two trusted Application images and the Application package carries a correct digital signature of the Application package. +- Another Application package included untrusted Application image which carry wrong digital signature of Application image and the Application package carries a correct digital signature of the Application package. +- There are a NFO, or a simulated NFO. A certificate or public key which is used to verify the digital signature of Application image has been pre-configured in the NFO. This certificate is trusted by the operator. It means the digital signature of the Application image is successfully verified by using the public key in the certificate trusted by the operator. + +#### Execution steps + +Execute the following steps: + +1. Review the documentation provided by the vendor describing how digital signature of the Application image is verified. +2. The tester uploads an Application package included two trusted Application images into a NFO. The NFO verifies the Application images by validating each digital signature of the Application image using the pre-configured certificate or the public key according to the documentation. +3. The tester uploads another Application package included un-trusted Application image into NFO. The NFO verifies the Application image(s) by validating each digital signature of the Application image using the pre-configured certificate or the public key according to the documentation. + +#### Expected Results + +In the step 2, the signatures of the Application images are successfully validated, and the Application package is successfully on boarded into the NFO; + +In the step 3, the signature of the un-trusted Application image is failed to be validated and the Application package is not on boarded into the NFO. + +**Expected format of evidence:** + +Snapshots containing the result of the Application package on boarding. + +## 19.4 Application image deployment security + +**Requirement Name:** Application image deployment security + +**Requirement Reference:** REQ-SEC-ALM-PKG-12, clause 5.3.2.1.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-IMG-04, T-AppLCM-02 + +**DUT/s:** O-CU, O-DU, Near-RT RIC, xApps, rApps + +**Test Name:** TC\_APP\_IMAGE\_VULNERABILITY\_CHECK\_ON\_DEPLOY + +**Purpose:** The purpose of this test is to verify that an Application image is free from known vulnerabilities. + +**Procedure and execution steps****Preconditions** + +O-Cloud with Application image scanning tools integrated. + +**Execution steps** + +1. Deploy an Application image known to have vulnerabilities: + - Select an Application image with known vulnerabilities, such as an image with outdated software or documented security issues. + - Attempt to deploy the image to an O-Cloud using the appropriate deployment configuration. + - Monitor the deployment process and capture any error messages or logs. +2. Deploy an Application image with outdated or unapproved software libraries: + - Create a custom Application image that includes outdated or unapproved software libraries. + - Attempt to deploy the custom image to an O-Cloud using the appropriate deployment configuration. + - Monitor the deployment process and capture any error messages or logs. + +**Expected Results** + +1. For the first step, the container image with known vulnerabilities is rejected or flagged as insecure, preventing its deployment. +2. For the second step, the container image with outdated or unapproved software is blocked from deployment, ensuring compliance with security policies. + +**Expected format of evidence:** + +1. Vulnerability scan reports generated by the Application image scanning tool, indicating the detected vulnerabilities and their severity. +2. Rejection logs or error messages from the Application image registry or O-Cloud, indicating the rejection or blocking of insecure images. + +--- + +## 20 Security tests of Common Application Lifecycle Management + +### 20.1 Overview + +This clause contains security tests to validate the security protection relevant to Common App LCM. + +### 20.2 Application package + +#### 20.2.1 Application package signature verification + +**Requirement Name:** Application package authenticity and integrity protection + +**Requirement Reference:** REQ-SEC-ALM-PKG-2, REQ-SEC-ALM-SU-1, clause 5.3.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** “The Application package shall be signed by the Application Provider prior to its delivery to the Service Provider to ensure its authenticity and integrity.” + +**Threat References:** T-IMG-01, T-NEAR-RT-02, T-rAPP-05, T-xApp-02 + +**DUT/s:** Non-RT RIC, Near-RT RIC, O-CU, O-DU, O-RU, xApps, rApps + +**Test Name:** TC\_App\_Signature\_Verification + +**Purpose:** To verify the application package authenticity and integrity validation during onboarding and instantiation. + +#### Procedure and execution steps + +##### Preconditions + +- The Application package is signed by the Application Provider prior to its delivery to the Service Provider. +- The Application provider certificate (used to sign the Application Package) is issued by a CA trusted by the Service provider, and the root certificate of the CA is pre-installed at SMO. + +##### Execution steps + +Upon reception of the Application package from the Application Provider, the Service Provider verifies the Application Provider signature using the execution steps in clause 9.5.2. + +##### Expected Results + +Validation of the Application package’s Application Provider signature is successful. + +Signing of the Application package by the Service Provider is successful. + +Validation of Application package signature and the Service Provider signature during instantiation of the application is successful. If verification is unsuccessful, the Service Provider may suspend the application instantiation process. + +**Expected format of evidence:** Log files for each step of the procedure. + +#### 20.2.2 Minimum Requirements + +**Requirement Name:** Application package includes minimal artifacts. + +**Requirement Reference:** REQ-SEC-ALM-PKG-3, clause 5.3, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-09 + +**DUT/s:** O-RU, O-DU, O-CU, Near-RT RIC, xApp, rApp + +**Test Name:** TC\_App\_Pkg\_Min\_Artifacts + +**Purpose:** The purpose of this test is to verify that an Application package includes minimal artifacts according to REQ-SEC-ALM-PKG-3. + +**Procedure and execution steps** + +**Preconditions** + +Application package available for access. + +**Execution steps:** + +1. Access the Application package contents. +2. Verify the Application package includes minimally the following artifacts: + - a. Application software image + - b. Signing certificate + - c. Application provider signature(s) + +**Expected Results:** + +Application package includes the minimal artifacts required. + +**Expected format of evidence:** + +Screenshot(s) + +## 20.2.3 App Package Change Log + +**Requirement Name:** Application package shall have change logs. + +**Requirement Reference:** REQ-SEC-ALM-PKG-15, clause 5.3, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-O-RAN-09 + +**DUT/s:** O-RU, O-DU, O-CU, Near-RT RIC, xApp, rApp + +**Test Name:** TC\_App\_Pkg\_Change\_Log + +**Purpose:** The purpose of this test is to verify that the Application packages contains a change log according to REQ-SEC-ALM-PKG-15. + +**Procedure and execution steps** + +**Preconditions** + +Application package available for access. + +**Execution steps:** + +- Access the Application package and external artifacts if present. +- Verify the Application package or external artifacts includes change log. +- Verify latest version noted in change log matches the current Application version. + +**Expected Results:** + +Change log is included in the Application package. + +**Expected format of evidence:** + +Screenshot(s) + +## 20.3 Secure Decommissioning + +### 20.3.1 Post-Decommission Report + +**Requirement Name:** A complete post-decommission report shall be generated. + +**Requirement Reference:** REQ-SEC-ALM-DECOM-1, clause 5.3, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-AppLCM-06 + +**DUT/s:** O-RU, O-DU, O-CU, Near-RT RIC, xApp, rApp + +**Test Name:** TC\_App\_Decomm\_Report + +**Purpose:** The purpose of this test is to ensure a decommissioning report is generated for a decommissioned Application. + +**Procedure and execution steps****Preconditions** + +Ensure Application subject to decommissioning has no running instance(s) on O-RAN system. + +**Execution steps:** + +- 1) Execute decommissioning of Application +- 2) Generate report of decommissioning whether through manual or automated means + +**Expected Results:** + +Decommissioning report documenting Application decommissioning is generated. + +**Expected format of evidence:** + +A report detailing: + +- Decommissioned Application name and version +- Date and time of Application decommissioning +- Tasks performed during decommissioning + +- Other pertinent details + +## 20.3.2 Trust Artifact Revocation + +**Requirement Name:** Trust artifacts revoked during Application decommissioning. + +**Requirement Reference:** REQ-SEC-ALM-DECOM-3, clause 5.3, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** + +**Threat References:** T-AppLCM-06 + +**DUT/s:** O-RU, O-DU, O-CU, Near-RT RIC, xApp, rApp + +**Test Name:** TC\_App\_Trust\_Artifact\_Revocation + +**Purpose:** The purpose of this test is to verify that all trust artifacts associated with an Application are revoked at the time of Application decommissioning. + +**Procedure and execution steps** + +**Preconditions** + +- Locate and prepare Application trust artifacts for revocation. +- Ensure Application subject to decommissioning has no running instance(s) on O-RAN system. + +**Execution steps:** + +1. Revoke trust artifacts from Application subject to decommissioning. +2. Perform a scan and verify that all trust artifacts associated with Application have been revoked. +EXAMPLE: If trust artifact is a certificate, verify that certificate is in certification revocation list. +3. Execute decommissioning of Application. +4. Attempt to instantiate Application and verify that it cannot be re-instantiated without the trust artifacts. + +**Expected Results:** + +- All trust artifacts are removed from the Application and the decommissioned Application cannot be re-instantiated. + +**Expected format of evidence:** + +Screenshot(s), report + +--- + +## 21 Security test of O-CU-CP + +### 21.1 Overview + +The present clause contains 3GPP security test cases applicable to O-CU-CP and O-RAN specific O-CU-CP test cases. + +## 21.2 O-CU-CP 3GPP specific security functional requirements and test cases + +**Requirement Name:** 3GPP specific O-CU-CP security + +**Requirement Reference:** REQ-SEC-OCU-1, clause 5.1.4.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** “O-CU-CP and O-CU-UP shall meet the security requirements for gNB-CU-CP and gNB-CU-UP respectively”, as specified in TS 33.501 [25] + +**DUT/s:** O-CU-CP + +**Purpose:** To verify the O-CU-CP meet the security requirements for gNB-CU-CP + +**Test Name:** TC\_O\_CU\_CP\_3GPP\_33\_523\_Cl\_5\_2\_2 (As defined in clause 5.2.2 of TS 33.523 [23]) + +gNB-CU-CP specific security functional requirements and test cases specified in clause 5.2.2 of TS 33.523 [23] apply to O-CU-CP. + +## 21.3 O-RAN specific security functional requirements and test cases + +The TLS test cases in clause 6.3 of the present document apply to the O1 interface of O-CU-CP. + +The IPsec test cases in clause 6.4 of the present document apply to the E2 interface of O-CU-CP. + +--- + +# 22 Security test of O-CU-UP + +## 22.1 Overview + +The present clause contains 3GPP security test cases applicable to O-CU-UP and O-RAN specific O-CU-UP test cases. + +## 22.2 O-CU-UP 3GPP specific security functional requirements and test cases + +**Requirement Name:** 3GPP specific O-CU-UP security + +**Requirement Reference:** REQ-SEC-OCU-1, clause 5.1.4.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** “O-CU-CP and O-CU-UP shall meet the security requirements for gNB-CU-CP and gNB-CU-UP respectively”, as specified in TS 33.501 [25] + +**DUT/s:** O-CU-UP + +**Test Name:** TC\_O\_CU\_UP\_3GPP\_33\_523\_Cl\_6\_2\_2 (As defined in clause 6.2.2 of TS 33.523 [23]) + +**Purpose:** To verify the O-CU-CP meet the security requirements for gNB-CU-UP + +gNB-CU-UP specific security functional requirements and test cases specified in clause 6.2.2 of TS 33.523 [23] apply to O-CU-UP. + +## 22.3 O-RAN specific security functional requirements and test cases + +The TLS test cases in clause 6.3 of the present document apply to the O1 interface of O-CU-UP. + +The IPsec test cases in clause 6.4 of the present document apply to the E2 interface of O-CU-UP. + +--- + +## 23 Security test of O-DU + +### 23.1 Overview + +The present clause contains 3GPP security test cases applicable to O-DU and O-RAN specific O-DU test cases. + +### 23.2 O-DU 3GPP specific security functional requirements and test cases + +**Requirement Name:** 3GPP specific O-DU security + +**Requirement Reference:** REQ-SEC-ODU-1, clause 5.1.5.1, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** “O-DU shall meet the security requirements for gNB-DU” as specified in TS 33.501 [25]. + +**DUT/s:** O-DU + +**Test Name:** TC\_O\_DU\_3GPP\_33\_523\_CI\_7\_2\_2 (As defined in clause 7.2.2 of TS 33.523 [23]) + +gNB-DU specific security functional requirements and test cases specified in clause 7.2.2 of TS 33.523 [23] apply to O-DU. + +### 23.3 O-RAN specific security functional requirements and test cases + +The 802.1X Authenticator Validation test cases in clause 11.2.1 applies to O-DU for the network configuration where O-DU acts as an 802.1X authenticator. + +The 802.1X Supplicant Validation test cases in clause 11.2.2 apply to O-DU. + +The TLS test cases in clause 6.3 of the present document apply to the O1 interface and M-Plane of O-DU. + +The IPsec test cases in clause 6.4 of the present document apply to the E2 interface of O-DU. + +The SSH Server & Client test cases in clause 6.2 of the present document apply to the M-Plane of O-DU. + +--- + +## 24 End-to-End security test cases + +### 24.0 Overview + +This clause describes E2E tests evaluating and assessing the security aspects of an O-RAN conformant radio access network. + +The O-RU, O-DU, O-CU-CP and O-CU-UP as defined in O-RAN Architecture Description [1] is the System under Test (SUT) and can be viewed as an integrated black box in the context of the E2E security testing. + +### 24.1 3GPP Security Assurance Specification (SCAS) + +For NR technology, Table 24-1 applies. The test cases referenced in this table are from 3GPP TS 33.511 [8], which are applied to the O-RAN system. The table also indicates the applicable technology, specifying whether each test case pertains to NR NSA (Non-Standalone) and/or NR SA (Standalone). + +For LTE technology, Table 24-2 applies. The test cases referenced in this table are from 3GPP TS 33.216 [9], which are applied to the O-RAN system. + +The tables also contain the information relative to the 3GPP releases affected for each test case. + +**Table 24-1: List of SCAS Test Cases for NR and applicable technology from Clause 4.2.2 of 3GPP TS 33.511** + +| Test Case (O-RAN Ref. #) | Test Case (3GPP clause number and title) | Applicable Technology | Applicable 3GPP Releases | +|--------------------------|-----------------------------------------------------------------------------------|-----------------------------------|--------------------------| +| TC_SCAS_NR_E2E_24.1.1 | 4.2.2.1.1
    Integrity protection of RRC-signalling | NR NSA (Options 3 and 4)
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.2 | 4.2.2.1.2
    Integrity protection of user data | NR NSA (Options 4 and 7)
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.3 | 4.2.2.1.4
    RRC integrity check failure | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.4 | 4.2.2.1.5
    UP integrity check failure | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.5 | 4.2.2.1.6
    Ciphering of RRC-signalling | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.6 | 4.2.2.1.7
    Ciphering of user data | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.7 | 4.2.2.1.8
    Replay protection of user data | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.8 | 4.2.2.1.9
    Replay protection of RRC-signalling | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.9 | 4.2.2.1.10
    Ciphering of user data based on the security policy sent by the SMF | NR NSA (Options 4 and 7)
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.10 | 4.2.2.1.11
    Integrity of user data based on the security policy sent by the SMF | NR NSA (Options 4 and 7)
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.11 | 4.2.2.1.12
    AS algorithms selection | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.12 | 4.2.2.1.13
    Key refresh | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.13 | 4.2.2.1.14
    Bidding down prevention in Xn-handovers | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.14 | 4.2.2.1.15
    AS protection algorithm selection | NR NSA
    NR SA | 16
    17
    18 | + +| | | | | +|------------------------|----------------------------------------------------------------------------------|-----------------|----------------| +| TC_SCAS_NR_E2E_24.1.15 | 4.2.2.1.16
    Control plane data confidentiality protection over N2/Xn interface | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.16 | 4.2.2.1.17
    Control plane data integrity protection over S1/NG/Xn interface | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.17 | 4.2.2.1.18
    Key update on dual connectivity | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.18 | 4.2.2.1.19
    User plane security activation in Inactive scenario | NR NSA
    NR SA | 16
    17
    18 | +| TC_SCAS_NR_E2E_24.1.19 | 4.2.2.1.20
    User plane data confidentiality protection over N3/Xn interface | NR NSA
    NR SA | 18 | +| TC_SCAS_NR_E2E_24.1.20 | 4.2.2.1.21
    User plane data integrity protection over N3/Xn interface | NR NSA
    NR SA | 18 | + +**Table 24-2: List of SCAS Test Cases for LTE and applicable technology from Clause 4.2.2 of 3GPP TS 33.216** + +| Test Case (O-RAN Ref. #) | Test Case (3GPP clause number and title) | Applicable Technology | Applicable 3GPP Releases | +|--------------------------|-----------------------------------------------------------------------|-----------------------|--------------------------| +| TC_SCAS_LTE_E2E_24.1.1 | 4.2.2.1.1
    Control plane data confidentiality protection over S1/X2 | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.2 | 4.2.2.1.2
    Control plane data integrity protection over S1/X2 | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.3 | 4.2.2.1.3
    User plane data ciphering | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.4 | 4.2.2.1.4
    User plane data integrity protection | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.5 | 4.2.2.1.5
    AS algorithms selection | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.6 | 4.2.2.1.6
    RRC integrity protection | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.7 | 4.2.2.1.7
    Selection of EIA0 | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.8 | 4.2.2.1.8 (1)
    Key refresh (PDCP Count) | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.9 | 4.2.2.1.8 (2)
    Key refresh (DRB ID) | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.10 | 4.2.2.1.9
    AS integrity algorithm selection | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.11 | 4.2.2.1.10
    Bidding down prevention in X2-handovers | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.12 | 4.2.2.1.11
    AS protection algorithm selection | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.13 | 4.2.2.1.12
    RRC and UP downlink ciphering | LTE | 16
    17
    18 | + +| | | | | +|-------------------------|---------------------------------------------------------------|-----|----------------| +| TC_SCAS_LTE_E2E_24.1.14 | 4.2.2.1.13
    Map a UE NR security capability | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.15 | 4.2.2.1.14
    UE NR security capability | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.16 | 4.2.2.1.15
    Bidding down prevention in X2-handovers | LTE | 16
    17
    18 | +| TC_SCAS_LTE_E2E_24.1.17 | 4.2.2.1.16
    Integrity protection of user data | LTE | 18 | +| TC_SCAS_LTE_E2E_24.1.18 | 4.2.2.1.17
    Select the right UP integrity protection policy | LTE | 18 | +| TC_SCAS_LTE_E2E_24.1.19 | 4.2.2.1.18
    Select the right UP IP policy | LTE | 18 | +| TC_SCAS_LTE_E2E_24.1.20 | 4.2.2.1.19
    Select the right UP IP policy in S1 handover | LTE | 18 | +| TC_SCAS_LTE_E2E_24.1.21 | 4.2.2.1.20
    Bidding down prevention for UP IP Policy | LTE | 18 | + +## 24.2 DoS, fuzzing and blind exploitation test + +Due to the open and disaggregated nature of the O-RAN system (SUT), the attack surfaces associated with some of its critical transport protocols and major interfaces of the O-RAN system become easy targets for potential attackers. Cyberattacks like DoS, fuzzing and blind exploitation types are easy to launch, require little information on the target system, and could cause significant performance degradation, or even the service interruption if not properly mitigated. + +The duration of test TRAFFIC GENERATION specified in this clause shall be at minimum 3 minutes. + +The **Table 24-3** summarizes the test cases and the applicable technology. + +Table 24-3: End-to-end test cases and applicable technology + +| | | Applicable technology | | | +|-----------|-------------------------------------|-----------------------|-----|----| +| Test case | | LTE | NSA | SA | +| Test ID | Name | | | | +| 24.2.1.1 | TC_E2E_ODU_SPlane_DoS | N/A | Y | Y | +| 24.2.1.2 | TC_E2E_ODU_SPlane_Robustness | N/A | Y | Y | +| 24.2.2.1 | TC_E2E_ODU_CPlane_eCPRI_DoS | N/A | Y | Y | +| 24.2.2.2 | TC_E2E_ODU_CPlane_eCPRI_Robustness | N/A | Y | Y | +| 24.2.2.3 | TC_E2E_ORU_CPlane_eCPRI_DoS | N/A | Y | Y | +| 24.2.2.4 | TC_E2E_ORU_CPlane_eCPRI_Robustness | N/A | Y | Y | +| 24.2.3.1 | TC_E2E_NearRTRIC_A1_DoS | N/A | Y | Y | +| 24.2.3.2 | TC_E2E_NearRTRIC_A1_Robustness | N/A | Y | Y | +| 24.2.3.3 | TC_E2E_NearRTRIC_A1_Vulnerabilities | N/A | Y | Y | +| 24.2.4.1 | TC_E2E_OCloud_SideChannel_DoS | N/A | Y | Y | + +## 24.2.1 S-Plane + +### 24.2.1.1 S-Plane PTP DoS Attack + +**Requirement Name:** O-DU S-Plane DoS Attack + +**Requirement Reference:** REQ-SEC-DOS-1, clause 5.3.5.1, O-RAN Security Requirements and Control Specification [5] + +**Requirement Description:** “An O-RAN component with external network interface shall be able to withstand network transport protocol based volumetric DDoS attack without system crash and returning to service level after the attack.”. + +**Threat References:** T-O-RAN-09 + +**SUT/s:** O-RAN system + +**Test Name:** TC\_E2E\_ODU\_SPlane\_DoS + +**Purpose:** To verify that a predefined volumetric DoS attack against O-DU S-Plane will not crash the SUT, returning to service level after the attack. + +#### Procedure and execution steps + +#### Preconditions + +- The tester requires easy to access MAC address information of the O-DU’s open fronthaul interface and L2 connectivity (e.g. over L2 network switching device) to the target from the emulated attacker. +- The test requires the normal UE procedures and user-plane traffic can be handled properly through the SUT. + +**RECOMMENDATION:** Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN TIFG End-to-End Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +Refer to the diagram below for the test setup and configuration: + +![Figure 24-1: S-Plane O-DU Test setup diagram. The diagram shows an E2E O-RAN System box containing O-RU, Open Fronthaul, O-DU, O-CU, NRT-RIC, and SMO components. A red dashed line labeled 'S-Plane DoS attack' points from a red hat icon to the Open Fronthaul. The system is connected to 'UE or Emulated UE' on the left and '5GC or Emulated 5GC' on the right.](9c31fa0e3f197c05332681ea00b93e4a_img.jpg) + +Figure 24-1: S-Plane O-DU Test setup diagram. The diagram shows an E2E O-RAN System box containing O-RU, Open Fronthaul, O-DU, O-CU, NRT-RIC, and SMO components. A red dashed line labeled 'S-Plane DoS attack' points from a red hat icon to the Open Fronthaul. The system is connected to 'UE or Emulated UE' on the left and '5GC or Emulated 5GC' on the right. + +**Figure 24-1: S-Plane O-DU Test setup** + +### Execution steps + +The tester uses a test tool to generate different types of volumetric DoS attack against the MAC address of the O-DU S-Plane + +1. Volumetric tiers: 10Mbps, 100Mbps, 1Gbps +2. DoS Traffic random mixed of: generic Ethernet frames, PTP announce/sync message +3. DoS source address: spoofed MAC of T-GM/T-BC or T-TC (depending on the setup), random source MACs + +### Expected results + +1. During the test, the SUT maintains an operational level. +2. After the execution of the test, the degradation of service availability and performance of the SUT is not noticeable. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN TIFG End-to-End Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +**Expected format of evidence:** Traffic captures and/or report files + +### 24.2.1.2 S-Plane PTP Unexpected Input + +**Requirement Name:** O-DU S-Plane Robustness + +**Requirement Reference:** REQ-SEC-OFSP-4, clause 5.2.5.3.2, O-RAN Security Requirements and Control Specification [5] + +**Requirement Description:** The O-DU is able to detect and defend against application level attacks across the S-Plane interface, due to misbehaviour or malicious intent. + +**Threat References:** T-O-RAN-09 + +**SUT/s:** O-RAN system + +**Test Name:** TC\_E2E\_ODU\_SPlane\_Robustness + +**Purpose:** To verify that an unexpected (not in-line with protocol specification) input sent towards O-DU S-Plane will not compromise the security of the SUT. + +### Procedure and execution steps + +Preconditions + +- The test requires easy to access MAC address information of the O-DU's open fronthaul interface and L2 connectivity (e.g. over L2 network switching device) to the target from the emulated attacker. +- The test requires the normal UE procedures and user-plane traffic can be handled properly through the SUT. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN TIFG End-to-End Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +Refer to the diagram below for the test setup and configuration: + +![Figure 24-2: S-Plane PTP Unexpected Input Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, Open Fronthaul, O-DU, O-CU, SMO, and NRT-RIC components. A red dashed arrow labeled 'S-Plane Unexpected Input' points from a red hat icon (attacker) to the O-DU. The system is connected to 'UE or Emulated UE' on the left and '5GC or Emulated 5GC' on the right.](558b0f5362d427a561a4980c84e07bba_img.jpg) + +Figure 24-2: S-Plane PTP Unexpected Input Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, Open Fronthaul, O-DU, O-CU, SMO, and NRT-RIC components. A red dashed arrow labeled 'S-Plane Unexpected Input' points from a red hat icon (attacker) to the O-DU. The system is connected to 'UE or Emulated UE' on the left and '5GC or Emulated 5GC' on the right. + +**Figure 24-2: S-Plane PTP Unexpected Input Test Setup** + +### Execution steps + +1. The tester uses a packet capture tool to capture sample of legitimate PTP message sent towards the O-DU S-Plane +2. The tester uses fuzzing tool to replay the captured PTP message while mutating its content and keeping original source/destination MAC address. Send at least 250,000 iterations of mutated PTP message based on a random seed + +### Expected results + +During the execution of the test, the degradation of service availability and performance of the SUT is not noticeable. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN TIFG End-to-End Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +**Expected format of evidence:** Log files, traffic captures and/or reports + +## 24.2.2 C-Plane + +### 24.2.2.1 C-Plane eCPRI DoS Attack + +**Requirement Name:** O-DU C-Plane eCPRI DoS Attack + +**Requirement Reference:** REQ-SEC-DOS-1, clause 5.3.5.1, O-RAN Security Requirements and Control Specification [5] + +**Requirement Description:** “An O-RAN component with external network interface shall be able to withstand network transport protocol based volumetric DDoS attack without system crash and returning to service level after the attack.”. + +**Threat References:** T-CPLANE-O2, T-O-RAN-09 + +SUT/s: O-RAN system + +**Test Name:** TC\_E2E\_ODU\_CPlane\_eCPRI\_DoS + +**Purpose:** To verify that a predefined volumetric DoS attack against O-DU C-Plane will not crash the SUT, returning to service level after the attack. + +**Procedure and execution steps** + +**Preconditions** + +- The test requires easy to access MAC address information of the O-DU’s open fronthaul interface and L2 connectivity (e.g. over L2 network switching device) to the target from the emulated attacker. +- The test requires the normal UE procedures and user-plane traffic can be handled properly through the SUT. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN TIFG End-to-End Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +Refer to the diagram below for the test setup and configuration: + +![Figure 24-3: C-Plane eCPRI DoS Attack Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, Open Fronthaul, O-DU, O-CU, SMO, and NRT-RIC components. A red dashed line labeled 'C-Plane DoS attack' points from a red hat icon to the Open Fronthaul. The system is connected to 'UE or Emulated UE' on the left and '5GC or Emulated 5GC' on the right.](fdcb46f6325fceb68b1205598510159c_img.jpg) + +Figure 24-3: C-Plane eCPRI DoS Attack Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, Open Fronthaul, O-DU, O-CU, SMO, and NRT-RIC components. A red dashed line labeled 'C-Plane DoS attack' points from a red hat icon to the Open Fronthaul. The system is connected to 'UE or Emulated UE' on the left and '5GC or Emulated 5GC' on the right. + +**Figure 24-3: C-Plane eCPRI DoS Attack Test Setup** + +**Execution steps** + +Use test tool to generate several types of volumetric DoS attack against the MAC address of the O-DU C-Plane + +1. Volumetric tiers: 10Mbps, 100Mbps, 1Gbps +2. DoS Traffic types: eCPRI real-time Control data message over Ethernet. The C-Plane message types that are made to flow towards O-DU are i) LAA LBT Status and response messages, ii) Ack/Nack Messages, and iii) Wake-up Ready indication Messages. Refer to Figure 4.2-1 Lower layer fronthaul data flows in [26] +3. DoS source address random mixed of: spoofed MAC of O-RU(s), random source MACs + +#### Expected results + +1. During the test, the SUT maintains an operational level. +2. After the execution of the test, the degradation of service availability and performance of the SUT is not noticeable. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from TIFG E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +**Expected format of evidence:** Traffic captures and/or report files + +### 24.2.2.2 C-Plane eCPRI Unexpected Input + +**Requirement Name:** O-DU C-Plane Robustness + +**Requirement Reference:** REQ-SEC-OFCP-2, clause 5.2.5.1.2, O-RAN Security Requirements and Control Specification [5] + +**Requirement Description:** The O-DU is able to detect and defend against application level attacks across the C-Plane messages with O-RUs, due to misbehaviour or malicious intent. + +**Threat References:** T-O-RAN-09 + +**SUT/s:** O-RAN system + +**Test Name:** TC\_E2E\_ODU\_CPlane\_eCPRI\_Robustness + +**Purpose:** To verify that an unexpected (not in-line with protocol specification) input sent towards O-DU C-Plane will not compromise the security of the SUT. + +#### Procedure and execution steps + +##### Preconditions + +- The test requires easy to access MAC address information of the O-DU's open fronthaul interface and L2 connectivity (e.g. over L2 network switching device) to the target from the emulated attacker. +- The test requires the normal UE procedures and user-plane traffic can be handled properly through the SUT. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +Refer to the diagram below for the test setup and configuration: + +![Figure 24-4: C-Plane eCPRI Unexpected Input Test Setup. The diagram shows a test setup for the E2E O-RAN System. On the left, there are 'UE or Emulated UE' blocks. These connect to 'O-RU' (Open Radio Units) within the 'E2E O-RAN System' box. A red dashed line labeled 'C-Plane Unexpected Input' (with a red hat icon) points to the 'Open Fronthaul' interface between the O-RU and the O-Cloud. The O-Cloud contains 'O-DU' (Open Distributed Units) and 'O-CU' (Open Core Units). Above the O-Cloud is the 'SMO' (Service Based Interface) and 'NRT-RIC' (Non-Real Time Radio Intelligent Controller). The O-Cloud connects to '5GC or Emulated 5GC' (5G Core or Emulated 5G Core) on the right.](f88a52b8a4aaeb13886e77f02f1a348a_img.jpg) + +Figure 24-4: C-Plane eCPRI Unexpected Input Test Setup. The diagram shows a test setup for the E2E O-RAN System. On the left, there are 'UE or Emulated UE' blocks. These connect to 'O-RU' (Open Radio Units) within the 'E2E O-RAN System' box. A red dashed line labeled 'C-Plane Unexpected Input' (with a red hat icon) points to the 'Open Fronthaul' interface between the O-RU and the O-Cloud. The O-Cloud contains 'O-DU' (Open Distributed Units) and 'O-CU' (Open Core Units). Above the O-Cloud is the 'SMO' (Service Based Interface) and 'NRT-RIC' (Non-Real Time Radio Intelligent Controller). The O-Cloud connects to '5GC or Emulated 5GC' (5G Core or Emulated 5G Core) on the right. + +**Figure 24-4: C-Plane eCPRI Unexpected Input Test Setup** + +### Execution steps + +1. The tester uses a packet capture tool to capture sample of legitimate eCPRI message sent towards the O-DU C-Plane +2. The tester uses a fuzzing tool to replay the captured eCPRI message while mutating its content (message type and/or payload) and keeping original source/destination MAC address. Send at least 250,000 iterations of mutated eCPRI message based on a random seed + +### Expected results + +During the execution of the test, the degradation of service availability and performance of the SUT is not noticeable. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from TIFG E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +**Expected format of evidence:** Traffic captures and/or report files + +### 24.2.2.3 C-Plane eCPRI DoS Attack on O-RU + +**Requirement Name:** O-RU C-Plane eCPRI DoS Attack + +**Requirement Reference:** REQ-SEC-DOS-1, clause 5.3.5.1, O-RAN Security Requirements and Control Specification [5] + +**Requirement Description:** “An O-RAN component with external network interface shall be able to withstand network transport protocol based volumetric DDoS attack without system crash and returning to service level after the attack.” + +**Threat References:** T-O-RAN-09 + +**SUT/s:** O-RAN system + +**Test Name:** TC\_E2E\_ORU\_CPlane\_eCPRI\_DoS + +### Procedure and execution steps + +**Purpose:** To verify that a predefined volumetric DoS attack against O-RU C-Plane will not crash the SUT, returning to service level after the attack. + +## Preconditions + +The test requires easy to access MAC address information of the O-RU's open fronthaul interface and L2 connectivity (e.g. over L2 network switching device) to the target from the emulated attacker. The test requires the normal UE procedures and user-plane traffic can be handled properly through the SUT. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN TIFG End-to-End Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +Refer to the diagram below for the test setup and configuration: + +![Figure 24-5: C-Plane eCPRI DoS Attack on O-RU Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, SMO, NRT-RIC, O-DU, O-CU, and O-Cloud components. A red dashed line with a hat icon represents a C-Plane DoS attack on the O-RU. A red arrow points from the O-RU to the Open Fronthaul interface. The system is connected to UE or Emulated UE on the left and 5GC or Emulated 5GC on the right.](89f6747be259110cba3e5c06cf208a72_img.jpg) + +Figure 24-5: C-Plane eCPRI DoS Attack on O-RU Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, SMO, NRT-RIC, O-DU, O-CU, and O-Cloud components. A red dashed line with a hat icon represents a C-Plane DoS attack on the O-RU. A red arrow points from the O-RU to the Open Fronthaul interface. The system is connected to UE or Emulated UE on the left and 5GC or Emulated 5GC on the right. + +**Figure 24-5: C-Plane eCPRI DoS Attack on O-RU Test Setup** + +## Execution steps + +Use test tool to generate several types of volumetric DoS attack against the MAC address of the O-RU C-Plane + +1. Volumetric tiers: 10Mbps, 100Mbps, 1Gbps +2. DoS Traffic types: eCPRI real-time ctrl data message over Ethernet. The valid C-Plane message types that are made to flow towards O-DU [Reference Figure 4.3-1 Lower layer front haul data flows [26]] are i) Scheduling commands (DL & UL) & Beamforming commands, ii) LAA LBT configuration commands and requests iii) UE Channel information +3. DoS source address, a mixed of: spoofed MAC of O-DU(s), random source MACs + +## Expected results + +- During the test, the SUT maintains an operational level +- After the execution of the test, the degradation of service availability and performance of the SUT is not noticeable. + +**Expected format of evidence:** Traffic captures and/or report files + +## 24.2.2.4 C-Plane eCPRI Unexpected Input on O-RU + +**Requirement Name:** O-RU C-Plane Robustness + +**Requirement Reference:** REQ-SEC-OFDP-2, clause 5.2.5.1.2, O-RAN Security Requirements and Control Specification [5] + +**Requirement Description:** The O-RU is able to detect and defend against application level attacks across the C-Plane messages with O-DUs, due to misbehaviour or malicious intent. + +**Threat References:** T-O-RAN-09 + +**SUT/s:** O-RAN system + +**Test Name:** TC\_E2E\_ORU\_CPlane\_eCPRI\_Robustness + +**Purpose:** To verify that an unexpected (not in-line with protocol specification) input sent towards O-RU C-Plane will not compromise the security of the SUT. + +### Procedure and execution steps + +#### Preconditions + +- The test requires easy to access MAC address information of the O-RU's open fronthaul interface and L2 connectivity (e.g. over L2 network switching device) to the target from the emulated attacker. +- The test requires the normal UE procedures and user-plane traffic can be handled properly through the SUT. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the DUT. + +Refer to the diagram below for the test setup and configuration: + +![Figure 24-6: C-Plane eCPRI Unexpected Input on O-RU Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, SMO, NRT-RIC, O-DU, and O-CU components. A red dashed line with a hat icon represents 'C-Plane Unexpected Input at O-RU' entering the O-RU. A red solid line shows the 'Open Fronthaul' connection between O-RU and O-DU. The O-DU and O-CU are connected to the O-Cloud, which is then connected to a 5GC or Emulated 5GC block. A stack of blue boxes on the left represents 'UE or Emulated UE'.](964c20dffc46b8dc92c69a7df97537cb_img.jpg) + +Figure 24-6: C-Plane eCPRI Unexpected Input on O-RU Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, SMO, NRT-RIC, O-DU, and O-CU components. A red dashed line with a hat icon represents 'C-Plane Unexpected Input at O-RU' entering the O-RU. A red solid line shows the 'Open Fronthaul' connection between O-RU and O-DU. The O-DU and O-CU are connected to the O-Cloud, which is then connected to a 5GC or Emulated 5GC block. A stack of blue boxes on the left represents 'UE or Emulated UE'. + +**Figure 24-6: C-Plane eCPRI Unexpected Input on O-RU Test Setup** + +#### Execution steps + +1. The tester uses a packet capture tool to capture sample of legitimate eCPRI message sent towards the O-RU C-Plane. +2. The tester uses a fuzzing tool to replay the captured eCPRI message while mutating its content (message type and/or payload) and keeping original source/destination MAC address. Send at least 250,000 iterations of mutated eCPRI message based on a random seed. + +#### Expected results + +- After the execution of the test, the degradation of service availability and performance of the SUT is not noticeable. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from TIFG E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the DUT. + +**Expected format of evidence:** Traffic captures and/or report files + +## 24.2.3 A1 interface + +### 24.2.3.1 Near-RT RIC A1 Interface DoS Attack + +**Requirement Name:** Near-RT RIC A1 interface DoS recover + +**Requirement Reference:** REQ-SEC-NEAR-RT-6, clause 5.1.3.1, O-RAN Security Requirements and Control Specification [5] + +**Requirement Description:** “The Near-RT RIC shall be able to recover, without catastrophic failure, from a volumetric DDoS attack across the A1 interface, due to misbehaviour or malicious intent.” + +**Threat References:** T-O-RAN-09 + +**SUT/s:** O-RAN system + +**Test Name:** TC\_E2E\_NearRTRIC\_A1\_DoS + +**Purpose:** to verify that a predefined volumetric DoS attack against Near-RT RIC A1 interface will not crash the SUT, returning to service level after the attack. + +#### Procedure and execution steps + +#### Preconditions + +- The test requires easy to access IP address information of the Near-RT RIC’s A1 interface and a routable path to the target from the emulated attacker. +- The test requires the normal UE procedures and user-plane traffic can be handled properly through the SUT. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +Refer to the diagram below for the test setup and configuration: + +![Figure 24-7: Near-RT RIC A1 Interface DoS Attack Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, Open Fronthaul, O-Cloud (with O-DU, O-CU, and NRT-RIC), and SMO. A red hat icon labeled 'A1 interface DoS attack' sends a dashed red arrow to the NRT-RIC. To the left are 'UE or Emulated UE' blocks, and to the right is a '5GC or Emulated 5GC' block.](89b38dfb0db99f01009cbd6fb999f3e3_img.jpg) + +Figure 24-7: Near-RT RIC A1 Interface DoS Attack Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, Open Fronthaul, O-Cloud (with O-DU, O-CU, and NRT-RIC), and SMO. A red hat icon labeled 'A1 interface DoS attack' sends a dashed red arrow to the NRT-RIC. To the left are 'UE or Emulated UE' blocks, and to the right is a '5GC or Emulated 5GC' block. + +**Figure 24-7: Near-RT RIC A1 Interface DoS Attack Test Setup** + +#### Execution steps + +1. The tester uses a test tool to generate several types of volumetric DoS attack against the IP address of the Near-RT RIC A1 interface: +2. Volumetric tiers: 10Mbps, 100Mbps, 1Gbps +3. DoS Traffic random mixed of: generic UDP packets, HTTP/HTTPs REST API calls +4. DoS source address: spoofed IP of Non-RT RIC, random source IPs or broadcast IP (UDP only) + +#### Expected results + +1. During the test, the SUT maintains an operational level. +2. After the execution of the test, the degradation of service availability and performance of the SUT is not noticeable. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from TIFG E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +**Expected format of evidence:** Traffic captures and/or report files + +### 24.2.3.2 Near-RT RIC A1 Interface Unexpected Input + +**Requirement Name:** Near-RT RIC A1 Robustness + +**Requirement Reference:** REQ-SEC-NEAR-RT-7, clause 5.1.3.1, O-RAN Security Requirements and Control Specification [5] + +**Requirement Description:** “The Near-RT RIC shall be able to detect and defend against content-related attacks across the A1 interface, due to misbehaviour or malicious intent.” + +**Threat References:** T-O-RAN-09 + +**SUT/s:** O-RAN system + +**Test Name:** TC\_E2E\_NearRTRIC\_A1\_Robustness + +**Purpose:** To verify that an unexpected (not in-line with protocol specification) input sent towards Near-RT RIC A1 interface will not compromise the security of the SUT. + +### Procedure and execution steps + +#### Preconditions + +- The test requires easy to access IP address information of the Near-RT RIC's A1 interface and a routable path to the target from the emulated attacker. +- The test requires the normal UE procedures and user-plane traffic can be handled properly through the SUT. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +Refer to the diagram below for the test setup and configuration: + +![Figure 24-8: Near-RT RIC A1 Interface Unexpected Input Test Setup. The diagram shows an E2E O-RAN System box containing SMO, NRT-RIC, O-DU, O-CU, and O-Cloud components. An attacker (red hat icon) sends 'A1 interface Unexpected Input' to the NRT-RIC. The system also includes O-RU, Open Fronthaul, and 5GC or Emulated 5GC components. A stack of blue boxes on the left represents 'UE or Emulated UE'.](b991f6dd9f96ef880216f721ee18f440_img.jpg) + +Figure 24-8: Near-RT RIC A1 Interface Unexpected Input Test Setup. The diagram shows an E2E O-RAN System box containing SMO, NRT-RIC, O-DU, O-CU, and O-Cloud components. An attacker (red hat icon) sends 'A1 interface Unexpected Input' to the NRT-RIC. The system also includes O-RU, Open Fronthaul, and 5GC or Emulated 5GC components. A stack of blue boxes on the left represents 'UE or Emulated UE'. + +**Figure 24-8: Near-RT RIC A1 Interface Unexpected Input Test Setup** + +#### Execution steps + +1. The tester uses a packet capture tool to capture sample of legitimate HTTP/HTTPs REST API message sent towards the Near-RT RIC A1 interface +2. The tester uses a fuzzing tool to replay the captured HTTP/HTTPs REST API message while mutating its content and keeping original source/destination IP/port. Send at least 250,000 iterations of mutated HTTP/HTTPs REST API message based on a random seed + +#### Expected results + +1. During the execution of the test, the degradation of service availability and performance of the SUT is not noticeable. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from TIFG E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +**Expected format of evidence:** Traffic captures and/or report files + +### 24.2.3.3 Near-RT RIC A1 Vulnerability Assessment + +**Requirement Name:** Near-RT RIC A1 Vulnerability Assessment + +**Requirement Reference:** REQ-SEC-SYS-1, clause 5.3.6, O-RAN Security Requirements and Control Specification [5] + +**Requirement Description:** “Known vulnerabilities in the OS and applications of an O-RAN component shall be clearly identified”. + +**Threat References:** T-OPENSRC-01, T-OPENSRC-02 + +**SUT/s:** O-RAN system + +**Test Name:** TC\_E2E\_NearRTRIC\_A1\_Vulnerabilities + +**Purpose:** To verify that exploitation attempts of well-known vulnerabilities executed blindly against Near-RT RIC A1 interface will not compromise security of the SUT + +#### Procedure and execution steps + +##### Preconditions + +- The test requires easy to access IP address information of the Near-RT RIC’s A1 interface and a routable path to the target from the emulated attacker. +- The test requires the normal UE procedures and user-plane traffic can be handled properly through the SUT. +- The test requires the vulnerability scanning tool has up-to-date database of well-known vulnerabilities (signatures/plugins) based on Common Vulnerabilities and Exposures (CVE). Document the actual version of vulnerability database (signatures/plugins) for further reference. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +Refer to the diagram below for the test setup and configuration: + +![Figure 24-9: Near-RT RIC A1 Vulnerability Assessment Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, Open Fronthaul, O-Cloud (with O-DU, O-CU, and NRT-RIC), and SMO. A red dashed arrow labeled 'Exploitation over A1 interface' points from a red hat icon (attacker) to the NRT-RIC. To the left are 'UE or Emulated UE' blocks, and to the right is a '5GC or Emulated 5GC' block.](24bfc42bd397863515083293d98bda3e_img.jpg) + +Figure 24-9: Near-RT RIC A1 Vulnerability Assessment Test Setup. The diagram shows an E2E O-RAN System box containing O-RU, Open Fronthaul, O-Cloud (with O-DU, O-CU, and NRT-RIC), and SMO. A red dashed arrow labeled 'Exploitation over A1 interface' points from a red hat icon (attacker) to the NRT-RIC. To the left are 'UE or Emulated UE' blocks, and to the right is a '5GC or Emulated 5GC' block. + +**Figure 24-9: Near-RT RIC A1 Vulnerability Assessment Test Setup** + +#### Execution steps + +The tester uses a vulnerability scanning tool to execute a scan against the IP address of the Near-RT RIC A1 interface. The scan should have the following parameters defined: + +- **TCP Ports:** Port scanner scans all TCP ports in range 0-65535 on the IP interface of SUT. TCP SYN/ACK response by SUT are interpreted as open port. +- **UDP Ports:** All UDP ports documented in vendor-provided list. Other UDP ports may be considered as open for the purpose of service detection. +- **Safe Checks:** Disabled (to make sure that exploitation attempts of the vulnerabilities will be performed) + +NOTE: Due to the nature of UDP protocol, there is no simple method of open port detection similar to TCP/SCTP methods based on analysis of response message type (TCP: SYN/ACK, SCTP: INIT-ACK). In case of UDP, open port detection inevitably relies on service detection which is discussed in step 2 of this test procedure. In practice, port scans of entire UDP port range 0-65535 are impractical and time consuming. Typically, service detection is performed only for subset of UDP ports. UDP port subset selection is arbitrary and not standardized. Service detection in this test procedure is required for UDP ports from vendor-provided list and is optional for other UDP ports. + +### Expected results + +During the execution of the test, the degradation of service availability and performance of the SUT is not noticeable. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from TIFG E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +**Expected format of evidence:** Tool testing report and traffic captures + +## 24.2.4 O-Cloud + +### 24.2.4.1 O-Cloud side-channel DoS attack + +**Requirement Name:** O-Cloud DoS Attack + +**Requirement Reference:** REQ-SEC-DOS-1, clause 5.3.5.1, O-RAN Security Requirements and Control Specification [5] + +**Requirement Description:** “An O-RAN component with external network interface shall be able to withstand network transport protocol based volumetric DDoS attack without system crash and returning to service level after the attack.”. + +**Threat References:** T-O-RAN-09 + +**SUT/s:** O-RAN system + +**Test Name:** TC\_E2E\_OCloud\_SideChannel\_DoS + +**Purpose:** To verify that a noisy neighbour DoS attack against O-Cloud for resource starvation will not crash the SUT, returning to service level after the attack. + +### Procedure and execution steps + +#### Preconditions + +- The test requires access to the O-Cloud platform hosting the network slice(s) of the O-RAN system. +- The test requires the normal UE procedures and user-plane traffic can be handled properly through the SUT. +- Logging and alerts in the O-cloud are enabled. Network monitoring tools may be used. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from O-RAN E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +Refer to the diagram below for the test setup and configuration: + +![Figure 24-10: O-Cloud side-channel DoS attack Test Setup. The diagram shows an E2E O-RAN System architecture. On the left, there are 'UE or Emulated UE' blocks. These connect to 'O-RU' (Open Radio Units) which connect to an 'Open Fronthaul' block. The Open Fronthaul connects to the 'O-Cloud'. Inside the O-Cloud, there are 'O-DU' (Open Distributed Units), 'O-CU' (Open Core Units), and 'NRT-RIC' (Non-Real-Time Radio Intelligent Controller). The O-Cloud connects to '5GC or Emulated 5GC' (5G Core or Emulated 5G Core). A red dashed arrow labeled 'Side-channel DoS attack' points from a red devil icon towards the O-Cloud, indicating the attack vector.](59bc9dbeea16696908bb4044da95fbac_img.jpg) + +Figure 24-10: O-Cloud side-channel DoS attack Test Setup. The diagram shows an E2E O-RAN System architecture. On the left, there are 'UE or Emulated UE' blocks. These connect to 'O-RU' (Open Radio Units) which connect to an 'Open Fronthaul' block. The Open Fronthaul connects to the 'O-Cloud'. Inside the O-Cloud, there are 'O-DU' (Open Distributed Units), 'O-CU' (Open Core Units), and 'NRT-RIC' (Non-Real-Time Radio Intelligent Controller). The O-Cloud connects to '5GC or Emulated 5GC' (5G Core or Emulated 5G Core). A red dashed arrow labeled 'Side-channel DoS attack' points from a red devil icon towards the O-Cloud, indicating the attack vector. + +**Figure 24-10: O-Cloud side-channel DoS attack Test Setup** + +Noisy neighbour VNF(s) can be deployed into an existing slice or a new slice of the shared resources with the existing slice under test. + +### Execution steps + +1. The tester uses test tool (through O-Cloud MANO) to instantiate noisy neighbour VNFs. + - a. Noisy neighbour tenant: existing slice or a new slice of the shared resources with the existing slice. + - b. The Noisy Neighbour tenants utilizes these shared resources including CPU, memory, storage, and network. The Noisy Neighbour tenants exhaust all the remaining shared resources. The duration of the test is at least 3 minutes or long enough to cover the benchmarking tests. +2. Run the benchmark test again with the noisy neighbours. +3. Check the logs and alerts that are associated to the test at step 2 and 3. + +### Expected results + +- After the execution of the test, the degradation of service availability and performance of the SUT is not noticeable. +- The Noisy Neighbour attack is properly logged and alerted by the O-Cloud. + +RECOMMENDATION: Use clause 5.6 Bidirectional throughput in different radio conditions and clause 6.1 Data Services tests from TIFG E2E Test Specifications [4] as a benchmark for indicating correct behaviour of the SUT. + +**Expected format of evidence:** Logs, results, screenshots, report + +--- + +## 25 Security test of Shared O-RU + +### 25.1 Overview + +This clause contains security tests to validate security controls related to the Shared O-RU and the Shared O-RU architecture. + +### 25.2 Shared O-RU test cases + +#### 25.2.1 mTLS for mutual authentication + +**Requirement Name:** SEC-CTL-SharedORU-1 + +**Requirement Reference:** Clause 5.1.9.2, Security Controls, Shared O-RU, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** mTLS support on Shared O-RU + +**Threat References:** T-SharedORU-06 + +**DUT/s:** Shared O-RU + +**Test Name:** TC\_SharedORU\_mTLS + +**Purpose:** To verify the Shared O-RU is able to mutually authenticate with an O-RU Controller using mTLS, with PKI-based X.509 certificates. + +#### **Procedure and execution steps** + +#### **Preconditions** + +DUT shall be the Shared O-RU with mTLS 1.2, or 1.3, support enabled. + +#### **Execution steps** + +This test case follows the execution steps for mTLS specified in mTLS Execution steps, clause 6.3. + +#### **Expected results** + +The Shared O-RU supports mutual authentication with an O-RU Controller using mTLS. + +**Expected format of evidence:** Log entries and packet captures. + +#### 25.2.2 NACM Authorization + +**Requirement Name:** Open Fronthaul Interface security requirements + +**Requirement Reference:** Clause 5.1.9.2, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** NACM support for Shared O-RU + +**Threat References:** T-SharedORU-22, T-SharedORU-23 + +**DUT/s:** Shared O-RU + +**Test Name:** TC\_SharedORU\_NACM\_Authorization + +**Purpose:** To verify the Shared O-RU through is able to enforce role-based least privilege access control on the Open Fronthaul by using NACM [14]. + +### Procedure and execution steps + +#### Preconditions + +DUT shall be the Shared O-RU with: + +- IP enabled Open Fronthaul M-Plane interface, reachable from the authentication server; +- Valid certificate loaded for the server and necessary certificate authorities (CAs) +- Client's root CA required to validate NETCONF client certificate +- Valid TLS Client-to-NETCONF username mapping + +#### Execution steps + +First set up a host/device with TLS client software installed, valid client certificates, keys, root CA certificate for the server (Shared O-RU), and all intermediate CA certificates required to validate the client certificate. + +The following test steps shall be validated: + +5. Start the NETCONF-over-TLS session using OpenSSL `s_client` command to connect with DUT using TLSv1.2 or TLSv1.3 +6. Verify the session is established and mapped to the correct NETCONF user +7. Verify the global NACM enforcement control setting of + - a. `enable-nacm = true` + - b. `read-default = permit` + - c. `write-default = deny` + - d. `exec-default = deny` + - e. `enable-external-groups = true` +8. Verify the NACM rule sets for the pre-defined groups +9. Close the NETCONF session and TLS connection + +Upon availability of the NETCONF operations set(s) definition per NACM group, the NACM rule set(s) enforcement by the DUT shall be validated for each of those pre-defined groups listed above. + +#### Expected results + +The Shared O-RU shall support the NETCONF over TLS session over its Open Fronthaul M-Plane interface and NACM enforcement control settings. + +**Expected format of evidence:** Log entries and packet captures. + +## 25.2.3 TLS across Open Fronthaul + +**Requirement Name:** SEC-CTL-SharedORU-4 + +**Requirement Reference:** Clause 5.1.9.2, Security Controls, Shared O-RU, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** TLS on Shared O-RU + +**Threat References:** T-SharedORU-27, T-SharedORU-28 + +**DUT/s:** Shared O-RU + +**Test Name:** TC\_SharedORU\_TLS + +**Purpose:** To verify the Shared O-RU is able to establish a TLS session with an O-RU Controller and provide confidentiality and integrity protection for messages exchanged with the O-RU Controller. + +**Procedure and execution steps** + +**Preconditions** + +DUT shall be the Shared O-RU with TLS support enabled. + +**Execution steps** + +This test case shall follow the execution steps for TLS specified in TLS Execution steps, clause 6.3. + +**Expected results** + +Shared O-RU shall provide confidentiality and integrity protection for data in transit on the Open Fronthaul M-Plane interface. + +**Expected format of evidence:** Log entries and packet captures. + +## 25.2.4 Reject Password-based authentication + +**Requirement Name:** SEC-CTL-SharedORU-2 + +**Requirement Reference:** Clause 5.1.9.2, Security Controls, Shared O-RU, O-RAN Security Requirements and Controls Specifications [5] + +**Requirement Description:** Shared O-RU is able to reject password-based authentication on the Open Fronthaul M-Plane + +**Threat References:** T-SharedORU-04 + +**DUT/s:** Shared O-RU + +**Test Name:** TC\_SharedORU\_SSH\_Password\_Based\_Authentication + +**Purpose:** To verify the Shared O-RU can reject a SSH session using password-based authentication on the Open Fronthaul. + +**Procedure and execution steps** + +**Preconditions** + +DUT shall be the Shared O-RU with password-based authentication for SSH on the Open Fronthaul disabled. + +**Execution steps** + +1. Enable SSH on the Open Fronthaul for the Shared O-RU. Ensure password-based authentication is not enabled on the Shared O-RU for SSH on the Open Fronthaul. +2. Configure the O-RU Controller as the SSH client with password-based authentication on the Open Fronthaul M-Plane. +3. Attempt to establish the Open Fronthaul M-Plane session between the Shared O-RU and O-RU Controller. + +**Expected results** + +The Shared O-RU rejects the Open Fronthaul M-Plane session with the O-RU Controller. + +**Expected format of evidence:** Log entries, packet captures, and/or screenshots. + +--- + +## Annex A (informative): Example of Security Testing Tools / Toolset + +**Table Annex A-1: List of sample open source security testing tools/toolset** + +| Testing Tool | Example(s) | +|-----------------------------|----------------------------------------------------------------------------------------------------------------------| +| DTLS scanning tool | open source "pySSLScan": https://github.com/DinoTools/pysslscan | +| IPsec IKE scanning tool | open source "ike-scan": https://github.com/royhills/ike-scan | +| Port scanner | open source "Nmap": https://nmap.org/ | +| SSH audit tool | open source "ssh-audit": https://github.com/jtesta/ssh-audit | +| TLS scanning tool | open source "sslyze": https://github.com/nabla-c0d3/sslyze | +| Software image signing tool | open source "Sigstore": https://github.com/sigstore | + +## Annex B (informative): Template of test report + +### A. GENERAL INFORMATION + +| | | +|-----------------------------------------------------------------------|-----------------------| +| A1 Name of test campaign | | +| A2 Version of the report – reference ID | A3 Date(s) of testing | +| A4 Contact person (tester) – incl. Name, Organization, E-mail address | | +| A4 Test location (lab) – incl. the address | | +| A5 Description of test campaign, summary of test results, conclusions | | + +List of tests - details of each test can be found in Section E. + +| Test No. | Test name | Test status [ PASS / FAIL / - ] | +|----------|-----------|---------------------------------| +| 01 | | | +| 02 | | | +| 03 | | | + +### B. TEST AND MEASUREMENT EQUIPMENT AND TOOLS + +| # | Equipment or tool | Type | Manufacture | Version (HW/SW) | Notes* | +|----|-------------------|------|-------------|-----------------|--------| +| 01 | | | | | | +| 02 | | | | | | +| 03 | | | | | | + +\* Specific details such as the sub-module version (such as vulnerability database version) + +### C. SYSTEM UNDER TEST + +| | | +|--------------------------------------------------|----------------------------| +| C1 Total number of DUTs included in SUT | C2 Deployment architecture | +| C3 Description of SUT – connection/block diagram | | + +DUT 1\* + +| | | | +|--------------------------------------------------------|-------------------------------|---------------------------| +| C3 Type | C4 Serial Number | C5 Supplier (manufacture) | +| C6 SW version | C7 HW version (if applicable) | | +| C8 Interface/IOT profile(s) if applied | | | +| C9 Description incl. parameters, setting/configuration | | | + +\* If SUT contains more DUTs, please copy the table + +#### D. TEST CONFIGURATION + +| | | +|---------------------------------------|--------------------| +| D1 Function(s) and Service(s) setting | D2 Network setting | +|---------------------------------------|--------------------| + +#### E. TEST RESULTS + +| | | +|-------------------------------------------------------------------------------------------------------------------------|------------------------------------| +| E1 Test No. | E2 Test name | +| E3 Date(s) of test execution | E4 Reference to test specification | +| E5 Utilized test and measurement equipment and tools, incl. the specific setting/configuration – reference to Section B | | +| E6 Test setup – connection/block diagram – deployment scenario | | +| E7 Execution steps – describe differences in comparison with the execution steps defined in test spec. – limitations | | +| E8 Test results –including outputs of the test properties and the attachment of log file(s) and/or screenshots | | +| E9 Notes, including observed issues with the solutions | | +| E10 Conclusions – pass/fail – assessment of test results in comparison with the expected results – gap analysis | | + +--- + +## Revision history + +| Date | Revision | Description | +|------------|----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2021.11.10 | 01.00 | Final initial version 01.00 | +| 2022.03.23 | 02.00.07 | Updated clauses:

    7.4 Network Protocol Fuzzing

    9.4 Software Bill of Materials (SBOM)

    11.2 Open Fronthaul Point-to-Point LAN Segment

    17.2 O1 Interface Network Configuration Access Control Model (NACM) Validation | +| 2022.07.19 | 03.00.01 | Applied the latest O-RAN technical specifications template

    Updated clauses:

    2.1 Normative references

    3.2 Abbreviations

    6.3 TLS

    6.6 OAuth 2.0

    9.5 Software Image Signing and Verification

    13.2 Testing of IPSec on E2

    14.2 Testing of TLS on A1 | +| 2022.07.25 | 03.00.02 | Updated cross-reference clause numbers of the test cases to align with latest WG11 specs

    Updated table of contents | +| 2023.03.09 | 04.00.00 | Updated clauses:

    • 14 Security Test of xApps
    • 15 Security test of Non-RT RIC
    • 16 Security test of rApps
    Added content to:

    • 14.2 xApp Signing and Verification
    • 16.2 rApp Signing and Verification
    Change wording in many places to align document with ETSI PAS | + +| | | | +|------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.07.10 | 05.00.00 |

    Added content to:

    • 9.4.3 SBOM Format
    • 9.4.4 SBOM Depth
    • 9.5.2 Software Signature Verification
    • 12.4 O-RU Security functional requirement and test cases
    • 13.2 IPSec on E2 interface
    • 13.3 Transactional APIs
    • 18.2 O2 Interface
    • 18.3 O-Cloud virtualization layer
    • 20 Security tests of Common Application Lifecycle Management
    • 21 Security test of O-CU-CP
    • 22 Security test of O-CU-UP
    • 23 Security test of O-DU

    Alignment for ETSI PAS

    | +| 2024.03.20 | 07.00.00 |
    • OAuth2.0 in Near-RT RIC
    • OCloud tests
    • Reorganization of interfaces testing (A1, R1)
    • Update of SCTP test cases, removing not related with security
    • TIFG E2E test cases adoption into clause 24, and needed update
    • SBOM and Package testing increased
    • E2 data validation tests for Near-RT RIC
    | + +| | | | +|------------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.07.17 | 08.00.00 |

    Added content to:

    • • 6.9 X.509
    • • 7.5 Denial of Service/Message flooding
    • • 7.6 Input validation and error handling
    • • 7.7 Secure configuration enforcement
    • • 11 Security tests of O-RAN interfaces
    • • 18.4 Application instantiation by O-Cloud
    • • 18.9 Secure time synchronization for O-Cloud
    • • 20.2 Application Package

    Removed content from:

    • • 6.2 SSH
    • • 6.3 TLS
    • • 6.4 DTLS
    • • 6.7 NACM
    • • 6.8 802.1X
    • • 7.5 Denial of Service/Message flooding
    • • 7.7 Secure configuration enforcement
    • • 9.4 SBOM
    • • 11 Security tests of O-RAN interfaces
    | +|------------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | | +|------------|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.11.27 | 09.00.00 |

    Changed content in:

    • • 6 Security Protocol & APIs Validation
    • • 7 Common Network Security Tests for O-RAN architecture elements
    • • 8 System security evaluation for O-RAN architecture element
    • • 9 Software security evaluation for O-RAN architecture elements
    • • 11.1 FH
    • • 14 Security test of xApps
    • • 18.4 Application instantiation deployment by O-Cloud
    • • 19.2 Executive environment protection
    • • 24 End-to-End security test cases

    Removed content from:

    • • 6.10.1 eCPRI Session Management
    • • 6.10.4 eCPRI Access Control
    • • 6.10.6 eCPRI Timeout Error Handling
    • • 8.4.9 Storage
    • • 9.4.5 SBOM completeness check
    • • 9.4.10 SBOM OSC Components
    • • 9.5.1 Software Image/Application Package Signing
    | +|------------|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +--- + +## Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|----------------------------------| +| 2024.11.27 | 09.00.00 | Published as Final version 09.00 | +| 2024.07.17 | 08.00.00 | Published as Final version 08.00 | +| 2024.03.20 | 07.00.00 | Published as Final version 07.00 | +| 2023.11.27 | 06.00.00 | Published as Final version 06.00 | +| 2023.07.11 | 05.00.00 | Published as Final version 05.00 | +| 2023.03.05 | 04.00.00 | Published as Final version 04.00 | +| 2022.07.19 | 03.00.01 | Published as Final version 03.00 | +| 2022.03.23 | 02.00.07 | Published as Final version 02.00 | +| 2021.11.10 | 01.00 | Published as Final version 01.00 | \ No newline at end of file diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/001cb669f9fc798ad9a87bc7485eab95_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/001cb669f9fc798ad9a87bc7485eab95_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4042b1d7c56add3978a24af915c55cd82ab25e3b --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/001cb669f9fc798ad9a87bc7485eab95_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5b18d816f705ec7da808ea5bd13958fdc6b1a1fc5af304e698f02abb2c694255 +size 4269 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/0151d9b02a74529631cbb8429e538486_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/0151d9b02a74529631cbb8429e538486_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d8fbe71b1c68aeb0a4fd642b0c20bea0bce0bca9 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/0151d9b02a74529631cbb8429e538486_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6c3094a4d0a9b30500d2c7a39c88794ee20e962bcc2f45699608f90192e08e47 +size 4059 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/050823a1415d4fd33a5c117e7b4adeef_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/050823a1415d4fd33a5c117e7b4adeef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3bfb769e7c1894bdf9532dfea918f9a79f77c3aa --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/050823a1415d4fd33a5c117e7b4adeef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:21386a7520fcaa50a5744cb117bc6bccaee5ed81a31e3bedd5fcde1d7694bc07 +size 4198 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/0961ebce1f0226fd25d2239ac365f2a2_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/0961ebce1f0226fd25d2239ac365f2a2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1bd830fbbc53b287783950fa9c7c681aa81e7b62 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/0961ebce1f0226fd25d2239ac365f2a2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e868299fcbc061d1bb48066848d82063e767ea6a8e07c8c34f1a1e989730febd +size 4276 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/0ff93d22c9205a6526977ba1fac22490_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/0ff93d22c9205a6526977ba1fac22490_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2518411ff9c2890cb25763f06001e115bc934fc --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/0ff93d22c9205a6526977ba1fac22490_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aeed10b45934bb6f13664c7ffbdae34e655ba6e2a7cfd6a9ab7a5c8ad0344d1a +size 57403 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/17e1cfb0d3bcfb291338c49328007440_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/17e1cfb0d3bcfb291338c49328007440_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a3bc57b4b005a58a1890cfd8a57d7eab04f14f0d --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/17e1cfb0d3bcfb291338c49328007440_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7c49bf571c7fc9c4ccea4f345fdd7b100fa810fe05423c090cb07a6d5e8fa31d +size 4115 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/21fda2f1ee366b5559a3d566408c0115_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/21fda2f1ee366b5559a3d566408c0115_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1257cc29b2b0b3cdc36c27cb0a8d188ca397c184 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/21fda2f1ee366b5559a3d566408c0115_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:03e857937b7e0e4eaeec4bee981d2598f4447886bd86400a4ef4960d1c3f367f +size 108669 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/2d8f4675a57cf79321444e12dcfcdeb9_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/2d8f4675a57cf79321444e12dcfcdeb9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..65fa25d6eee5d96581963ff4f1798d1f44778241 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/2d8f4675a57cf79321444e12dcfcdeb9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:362ff18a0017af97d02c395e3d018fbf85d89aae7fce702ab71837e5c8e9ee75 +size 4220 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/387f912751a6b3896c8a6e31cde4bd38_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/387f912751a6b3896c8a6e31cde4bd38_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8053ffea291c9df0c85ed5d3cdf304f1fd81a93c --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/387f912751a6b3896c8a6e31cde4bd38_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:42d1eca217282525313b5e952137823fccb8038f3d17fae11a129f2d7104830c +size 4195 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/3f56e44b74ab838f75b33171ab1f1257_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/3f56e44b74ab838f75b33171ab1f1257_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..924b694b4269f352bfa78c5c36be0e4fe0731fee --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/3f56e44b74ab838f75b33171ab1f1257_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dcbc54d9905cc9118421e853b275644f41158b8101ad048d939b8ffe26c215f5 +size 4075 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/42a911cdcd511e9913b56be38c3b3479_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/42a911cdcd511e9913b56be38c3b3479_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0a21c257419ec24333d729d4bf6c8eaf6e5d5c6b --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/42a911cdcd511e9913b56be38c3b3479_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:110647a9579f3a24f3557a54e6019c63816c404eb99de8ba12757739c0c32ff1 +size 4115 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/4726613a5052b2673468264a41fbbf15_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/4726613a5052b2673468264a41fbbf15_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f86dbbe5b5c13cf8bf7daa6eedf7f058697ce2cb --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/4726613a5052b2673468264a41fbbf15_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d8cd1b75f6df8db957c6648f4508b3ea5a75aa8e299c0be51e33059a799f76c3 +size 4254 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/547183b9630a9bcfff40dac9dfb214a1_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/547183b9630a9bcfff40dac9dfb214a1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..01cfad83e35052fdb097534ab11a1d45ffc535c4 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/547183b9630a9bcfff40dac9dfb214a1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7e9e6fd119b6400a722764940aaffd6d137e468a9b154f4760d135bd4c71e144 +size 70888 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/5f40703e176848f5c705a74cb9ed0731_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/5f40703e176848f5c705a74cb9ed0731_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..267b4f3dc4cbbc643c70104d02f9ab390f1fd0b5 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/5f40703e176848f5c705a74cb9ed0731_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5e73c90b56ad9e2d092833245fad09e77fd7abffaadf6187d20b17349a8ac6da +size 4047 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/63be4a407ba9b530c954ef3016b87aab_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/63be4a407ba9b530c954ef3016b87aab_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c357f0186e3f3e0505e3b6380858490106878c24 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/63be4a407ba9b530c954ef3016b87aab_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2223d3822d55b2f15270fdb9b269e8050338bdc5c4c5b9524fc7b14bdca1c6be +size 35060 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/6e654bfec2c61f0bddc774115f6b5c24_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/6e654bfec2c61f0bddc774115f6b5c24_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c68f18b0e531d953e0cfe2fc8fa9753066684e3e --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/6e654bfec2c61f0bddc774115f6b5c24_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cb7d51e9bd8480f74834a783710d8d9b1fc9e25144ba6d2b8b4c890431458cd +size 84589 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/7adcb0a1ca8872d64af5502faac4e6a2_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/7adcb0a1ca8872d64af5502faac4e6a2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c266b76fa5207c600e003272d0dc3d241b49ac1d --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/7adcb0a1ca8872d64af5502faac4e6a2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7c91a664a9d6346ac0f0113e9c822a5da03bfdd75294cafab7479590f7a851e9 +size 94253 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/85c8bc4c579f3c8bf60f87ec019a4d74_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/85c8bc4c579f3c8bf60f87ec019a4d74_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b5ca3af1edabe1a0f324af56592daba9ddb7eb9a --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/85c8bc4c579f3c8bf60f87ec019a4d74_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d55311cf7f9b3890a50aed727343c66870196593d051a9930785b267bd4d002e +size 4116 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/85d29166836161773bbb9ab4e9040300_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/85d29166836161773bbb9ab4e9040300_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e763b40f6a5f19d7c0507ce8c8a48c16fd05bc83 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/85d29166836161773bbb9ab4e9040300_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2a0520fa4592fe843aef33b99a934049910754ae914946c3ddb20124d0a5a6bc +size 40778 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/88034a31d26b933954218c538f6f899a_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/88034a31d26b933954218c538f6f899a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a4442730987c3c118129047615b1466f0f7c3875 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/88034a31d26b933954218c538f6f899a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8a89b0024927d05035dcb882a62cb16fffdf61afb5472bf2bf1ef9f2e89b8ec3 +size 4227 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/8f1e80bb3047ef5e53da06ca6c5f5eef_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/8f1e80bb3047ef5e53da06ca6c5f5eef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..844a4a08c1fc5d768fdddcf7417f8e4c87fd4656 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/8f1e80bb3047ef5e53da06ca6c5f5eef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:171e41cf018d817ecb807501c7e06136aafe5412d93e4add967c2bc3f6ac3810 +size 4200 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/93122c6f928a3e8a2456cc91b44f9e6f_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/93122c6f928a3e8a2456cc91b44f9e6f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7109d466ca8bc37596f8735a8f9273739a306a0b --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/93122c6f928a3e8a2456cc91b44f9e6f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c24fe3d4f8a6e9c17f4be560b705515fa4c7818c015e186ac65734247cd523c6 +size 4213 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/a833b4cd59eef40c1a3f0af9ac210734_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/a833b4cd59eef40c1a3f0af9ac210734_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0d91bd5295a728c152d96170e94472f5879be75b --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/a833b4cd59eef40c1a3f0af9ac210734_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9e933da3bb2d43aae341df3cf2d4ad8bbd6ba4f7f38ac4d5b356d50a4cd666d5 +size 4138 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/b6c2b0066492e4ce582d4cdec3770d02_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/b6c2b0066492e4ce582d4cdec3770d02_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ac57a2c452ad05d691cbebb3463e5be2be2381d --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/b6c2b0066492e4ce582d4cdec3770d02_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5f6f3ba901cea2b3b7599675699f547b13b04b2fe4e102b61691918992ec93ff +size 90479 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/c3fcb272beed51ee7f9588728a16bb9b_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/c3fcb272beed51ee7f9588728a16bb9b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7faa9e5baafddfe2104b504274c4db0ed65aca12 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/c3fcb272beed51ee7f9588728a16bb9b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1eb9d71c150862bedb96de3ad2ec4719dbd20282b65699441088ef69f9b8c127 +size 62333 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/caf7ff3f78f97f126216c830f43037e0_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/caf7ff3f78f97f126216c830f43037e0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cf5f43f831bf7ca22631538514918ed6d6075b0a --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/caf7ff3f78f97f126216c830f43037e0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:88cc39e16c51b1e6779919ebc483fcb00d7ee13ecb5c5cc609ea46f7cb8e9a7a +size 4267 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/cb14ded19604bd29f0a653b440d6e13a_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/cb14ded19604bd29f0a653b440d6e13a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2cab28a25322049994ded70e0b215057c140951a --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/cb14ded19604bd29f0a653b440d6e13a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:13f55e3a6739ce45376b189167325ad3c5a8792efa9660526d7e91ea540e91f7 +size 4104 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/d5642012ca098c8488a90421bd661f4f_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/d5642012ca098c8488a90421bd661f4f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f649a81e72bc9b37ce6d78cb581366cfff646d46 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/d5642012ca098c8488a90421bd661f4f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8425997a3a73874f662e97dee0e6d8e2f689e3d99543876c6367464f775983df +size 53477 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/d8fafc8adb2e51221a6cc3cd8b363ec4_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/d8fafc8adb2e51221a6cc3cd8b363ec4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2fbf784ff67c325d2de9a35e1ed8b6b58a9430a8 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/d8fafc8adb2e51221a6cc3cd8b363ec4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8c3de5086fc7c7a235edc74c90e76eb89e6f204d76ac266cfa069e7d728b28a7 +size 3975 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/e00d98f39f83524f8804a7ed4a5ee69c_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/e00d98f39f83524f8804a7ed4a5ee69c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..397d1d165c0995fad69a4b63bb35b6438f463a29 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/e00d98f39f83524f8804a7ed4a5ee69c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:747eec19a0c2dc91509884904e28fb7d03796b4cc243ed575873defa3afaed7e +size 4044 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/f64c5f190c5923dc7681a90a9e48a45f_img.jpg b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/f64c5f190c5923dc7681a90a9e48a45f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..83363f31fe807a9ae009918ce853a61f332eb84f --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/f64c5f190c5923dc7681a90a9e48a45f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70faba446cb7ef976d6d70a8cfc906e4a90b316eda010ff11a5dbee29e844ee6 +size 36349 diff --git a/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/raw.md b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..60d0512a42e80cd5e617c02d83ffdfc9bbff1b49 --- /dev/null +++ b/marked/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00/raw.md @@ -0,0 +1,1445 @@ + + +# --- **O-RAN Work Group 11 (Security Work Group)** + +## **Study on Security for Shared O-RU (SharedORU)** + +# --- Contents + +| | | | +|-----|------------------------------------------------------|----| +| 1 | Scope..... | 3 | +| 2 | References..... | 5 | +| 3 | Definitions of terms, symbols and abbreviations..... | 6 | +| 3.1 | Terms..... | 6 | +| 3.2 | Symbols..... | 6 | +| 3.3 | Abbreviations ..... | 7 | +| 4 | Shared O-RU Assets ..... | 8 | +| 4.1 | Architecture..... | 8 | +| 4.2 | Functions ..... | 9 | +| 4.3 | Interfaces ..... | 11 | +| 4.4 | Information..... | 12 | +| 5 | Threats..... | 14 | +| 5.1 | Threat Model..... | 14 | +| 5.2 | Threat Template ..... | 14 | +| 5.3 | Potential Threats and Exploits ..... | 15 | +| 5.4 | Shared O-RU Threats..... | 15 | +| 6 | Threat Analysis ..... | 17 | +| 6.1 | Lateral Movement Between Network Functions ..... | 19 | +| 6.2 | User Access Threats..... | 22 | +| 6.3 | Data Access Threats..... | 24 | +| 6.4 | Availability Threats..... | 26 | +| 6.5 | Configuration Threats ..... | 28 | +| 6.6 | Neutral Host Controller (NHC) Threats..... | 30 | +| 6.7 | Resiliency Threats..... | 32 | +| 7 | Security Controls ..... | 33 | +| 8 | Risk Assessment ..... | 35 | +| 8.1 | Lateral Movement Between Network Functions ..... | 35 | +| 8.2 | User Access Threats..... | 36 | +| 8.3 | Data Access Threats..... | 37 | +| 8.4 | Availability Threats..... | 37 | +| 8.5 | Configuration Threats ..... | 38 | +| 8.6 | Neutral Host Controller Threats..... | 39 | +| 8.7 | Resiliency Threats..... | 39 | +| 9 | Primary Security Issues..... | 41 | +| 10 | Recommendations..... | 42 | +| | Annex A: Shared O-RU All-in-One Architecture..... | 45 | +| | Annex change history..... | 47 | + +# 1 Scope + +This technical report provides the threat model and risk assessment for the Shared O-RU. The report identifies threats and risks and recommends potential security controls to protect against those threats through safeguards or mitigation. + +The steps of the threat modelling process are as follows: + +1. Identify assets: Identify the assets of the Shared O-RU that must be protected. +2. Identify threats: Identify the threats that could adversely impact the Shared O-RU and threats that can use the Shared O-RU to adversely impact other components of the O-RAN system. +3. Identify the attack surface and attack vectors: Identify the points in the Shared O-RU where an attacker could + - a. gain entry to a O-RU Host or O-RU Tenant (SRO) of a Shared O-RU + - b. gain entry to another O-RAN component through the Shared O-RU + - c. exploit a vulnerability or misconfiguration at the Shared O-RU + - d. compromise the Shared O-RU to degrade performance or impact availability + - e. expose data at rest / data in use at the Shared O-RU + - f. expose data in motion between the Shared O-RU and other O-RAN network functions +4. Measure risk: The extent to which confidentiality, integrity, or availability is threatened, based upon a risk-based analysis considering the impact level resulting from an attack and the likelihood of occurrence. +5. Recommend controls: The management, operational, and technical controls for an information system to protect the confidentiality, integrity and availability of the Shared O-RU and its information. + +The sections in this Shared O-RU Security Analysis Technical Report (TR) follow the process described above. + +This Technical Report makes the following considerations: + +- The attack surface of the Shared O-RU includes assets that are interfaces, functions, and data. + - Data-at-rest, Data-in-motion, and Data-in-use must be considered. + - O-RAN Alliance WG4 is in the process of defining optional architectures for Shared O-RU. This will influence the set of assets to be protected. +- The O-RAN Alliance is pursuing a zero-trust architecture (ZTA) for its specifications based upon NIST SP 800-207 [i.8]. This will affect the risk scoring as external and internal threats are considered. +- Security controls will be recommended for specifications of the Shared O-RU. The recommended controls provided in this report will be shared with the responsible O-RAN Alliance working group, + +such as WG1 and WG4, so that the appropriate specification relevant to the recommendation can be updated. + +- Some of the identified Shared O-RU assets may already be in scope for other ongoing WG11 security work items. The Shared O-RU Security Analysis Technical Report work item may inform those work items. + +# 2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- [i.1] O-RAN ALLIANCE PD: "O-RAN Document Drafting Rules (ODR)". +- [i.2] O-RAN ALLIANCE TS: "O-RAN Architecture Description (OAD)". +- [i.3] MVPC-FP-Shared-O-RU-Feature-Plan-v05.00, Shared O-RU Feature Plan +- [i.4] O-RAN ALLIANCE TS: "O-RAN Security Protocols Specifications". +- [i.5] O-RAN ALLIANCE TS: "O-RAN Security Requirements and Controls Specifications". +- [i.6] O-RAN ALLIANCE TR: "O-RAN Threat Modelling and Risk Assessment". +- [i.7] O-RAN ALLIANCE TS: "O-RAN Security Test Specifications". +- [i.8] Zero Trust Architecture, NIST SP 800-207, NIST, August 2020, . +- [i.9] US National Security Agency (NSA) / Cybersecurity and Infrastructure Security Agency (CISA), Security Guidance for 5G Cloud Infrastructures, Part I, Oct 28, 2021, Part II, Nov 18, 2021, Part III, Dec 2, 2021, Part IV, Dec 16, 2021. (as of Feb 28, 2022). +- [i.10] ISO/IEC 27001:2013 Information Security Management System (ISMS). +- [i.11] VOID +- [i.12] OWASP Top 10 Web Application Security Risks, 2021, . +- [i.13] Cloud Security Alliance (CSA), Top Threats to Cloud Computing: Egregious Eleven, 2019, . +- [i.14] Cloud Security Alliance (CSA), Top Threats to Cloud Computing: Pandemic Eleven, 2022, . +- [i.15] OWASP Top 10 Proactive Controls, 2021, +- [i.16] Center for Internet Security (CIS) Critical Security Controls, +- [i.17] Cloud Security Alliance (CSA) Cloud Control Matrix (CCM), +- [i.18] ISO/IEC 27001:2013 Information Security Management System (ISMS). +- [i.19] NIST SP 800-53r5, Security and Privacy Controls for Information Systems and Organizations, 2020. +- [i.20] O-RAN ALLIANCE TS: "Management Plane Specification". +- [i.21] NIST SP 800-57 Part 1 Rev. 5, Recommendation for Key Management, 2020 +- [i.22] IETF RFC 6066: "Transport Layer Security (TLS) Extensions: Extension Definitions" +- [i.23] IETF RFC 8446: "The Transport Layer Security (TLS) Protocol Version 1.3" + +# 3 Definitions of terms, symbols and abbreviations + +For the purposes of the present document, the following terms and definitions apply: + +## 3.1 Terms + +This document uses the verbal forms for the expression of provisions as defined in O-RAN Document Drafting Rules (ODR)[i.1]. + +This document uses the term Zero Trust Architecture (ZTA) as defined by US NIST in [i.8] and applied to 5G cloud deployments by US CISA in [i.9]. A ZTA provides protection from external and internal threats, assuming the following: + +1. there is no implicit trust granted to an asset based upon ownership, physical location, or network location [i.8]. +2. the adversary is already inside the network. Perimeter defenses are no longer sufficient to secure a network, and there should always be an assumption that a threat actor has established a foothold in the network [i.9]. + +This document uses the term “attack surface” defined by US NIST as + +*The set of points on the boundary of a system, a system element, or an environment where an attacker can try to enter, cause an effect on, or extract data from, that system, system element, or environment.* +[[https://csrc.nist.gov/glossary/term/attack\\_surface](https://csrc.nist.gov/glossary/term/attack_surface)] + +This document refers to “sensitive information” defined by US NIST as + +*information whose loss, misuse, or unauthorized access or modification could adversely affect security.* +[] + +**Trust Anchor (TA)** (as per [i.21], section 2.1): + +1. An authoritative entity for which trust is assumed. In a PKI, a trust anchor is a certification authority, which is represented by a certificate that is used to verify the signature on a certificate issued by that trust-anchor. The security of the validation process depends upon the authenticity and integrity of the trust anchor’s certificate. Trust anchor certificates are often distributed as self-signed certificates. +2. The self-signed public key certificate of a trusted CA. + +## 3.2 Symbols + +None + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 and the following apply: + +| | | +|-------|--------------------------------------| +| AI | Artificial Intelligence | +| DAR | Data at Rest | +| DIM | Data in Motion | +| DIU | Data in Use | +| gNB | gNodeB (applies to NR) | +| HTTP | Hypertext Transfer Protocol | +| HTTPS | Hypertext Transfer Protocol Secure | +| ML | Machine Learning | +| MNO | Mobile Network Operator | +| NF | Network Function | +| NHC | Neutral Host Controller | +| O-CU | Open-Centralized Unit | +| O-DU | Open-Distributed Unit | +| O-RU | Open-Radio Unit | +| OFH | Open Fronthaul | +| PII | Personally Identifiable Information | +| PKI | Public Key Infrastructure | +| SMO | Service Management and Orchestration | +| SOH | Shared Operator Host | +| SRO | Shared Resource Operator | +| TLS | Transport Layer Security | +| ZTA | Zero Trust Architecture | + +# 4 Shared O-RU Assets + +## 4.1 Architecture + +The potential benefits of Shared O-RU are RAN Sharing, Neutral Host, high RAN reliability (redundancy) and RAN processing pooling. Shared O-RU involves cooperation with the SMO, O-CU, O-DU, and O-RU network. Securing the Shared O-RU is imperative to protect the O-RAN deployment and each of its tenants. Five optional configurations are being considered for Shared O-RU [i.3] and while there are common security risks, each configuration may also introduce unique security risks. The Attack Surface of the Shared O-RU includes assets groups Functions, Interfaces, and Information, which each have assets that should be protected. The assets that should be protected are listed in the following sections. + +Figure 4.1-1 shows the Shared O-RU building blocks and protocol stack. + +![Figure 4.1-1: Shared O-RU Tenant/Host Split. This diagram illustrates the protocol stack and building blocks for a Shared O-RU, showing the separation between a Host and multiple Tenants (Tenant(1), Tenant(2)).](b6c2b0066492e4ce582d4cdec3770d02_img.jpg) + +The diagram illustrates the Shared O-RU building blocks and protocol stack, showing the separation between a Host and multiple Tenants (Tenant(1), Tenant(2)). + +**Host and Tenant Labels:** Host, Tenant(1), Tenant(2) + +**Protocol Stack Layers (from top to bottom):** + +- Application Layer:** Application, Application +- RU Object Model:** Netconf, SFTP +- AuthN (user+pwd/cert):** (Associated with Netconf) +- AuthZ Module Based ACM:** (Associated with Netconf) +- AuthZ Object Based ACM (based on SRO-id):** (Associated with SFTP) +- SSH** +- TCP** +- IP** +- Ethernet** + +**Host and Tenant Split Point:** A green oval indicates the split point, where the Host and Tenants are handled separately/isolated. + +**Host and Tenant Services:** + +- Host Services:** User Data, Real-Time Control, other eCPRI services +- Tenant Services:** G&M, Synchronization, Connection OAM + +**Protocol Stack Details:** + +- eCPRI Services:** User Data, Real-Time Control, other eCPRI services +- eCPRI protocol layer:** (Red dashed box) +- UDP:** (Dashed box) +- IPsec:** (Dashed box) +- Ethernet MAC:** VLAN (priority tag), MACsec +- Ethernet PHY:** (Dashed box) +- Ethernet OAM:** (Dashed box) + +Figure 4.1-1: Shared O-RU Tenant/Host Split. This diagram illustrates the protocol stack and building blocks for a Shared O-RU, showing the separation between a Host and multiple Tenants (Tenant(1), Tenant(2)). + +Figure 4.1-1: Shared O-RU Tenant/Host Split + +The following points are considered: + +- The Shared O-RU can be receiving data via a single/shared physical port. This connectivity is used to transfer tenant and host-specific controller functionality. +- The tenant/host-split point is the earliest point in the protocol stack when host and tenants are going to be separated/isolated. +- Each of the tenants can obtain access (i.e., read/write) to its own resources, and a tenant has no means to access neighbor resources. +- The host can obtain access (i.e., read/write) to common M-plane resources. +- The user will be authenticated by using username and password/certificate and in case of netconf/ssh by using public/private key. In successful case the user is obtaining authorization on Module Level. Access control management (ACM) functionality required on that protocol level. +- Every tenant who is requesting access to 'own'= tenant specific resources, needs to be identified using its unique SRO-Id, and after successful authentication, the tenant will be authorized to access its own resources. + +## 4.2 Functions + +The following functions should be considered in the Shared O-RU risk analysis: + +- ASSET-C-31: Shared O-RU +- ASSET-C-32: O-RU Host (Shared Operator Host) +- ASSET-C-33: O-RU Tenant (Shared Resource Operator) +- ASSET-C-34: O-DU Host (Shared Operator Host) +- ASSET-C-35: O-DU Tenant (Shared Resource Operator) +- ASSET-C-36: O-CU Host (Shared Operator Host), includes O-CU-CP and O-CU-CP software +- ASSET-C-37: O-CU Tenant (Shared Resource Operator), includes O-CU-CP and O-CU-CP software +- ASSET-C-38: SMO Host (Shared Operator Host) +- ASSET-C-39: SMO Tenant (Shared Resource Operator) +- Neutral Host Controller (NHC) + +NOTE: NHC is not an agreed upon function in the O-RAN architecture, but NHC is considered in scope for security analysis. + +Figures 4.2-1, 4.2-2, and 4.2-3 below show these assets in Shared O-RU architecture. + +![Figure 4.2-1 Security Architecture for Shared O-RU Options 1 and 2](f64c5f190c5923dc7681a90a9e48a45f_img.jpg) + +This diagram illustrates the security architecture for Shared O-RU Options 1 and 2. At the top is a green box labeled "SMO SOH". Below it, two vertical paths are shown. The left path consists of a blue box "O-CU SOH" connected to an orange box "O-DU SOH" via an "F1" interface. The right path consists of a blue box "O-CU SRO" connected to an orange box "O-DU SRO" via an "F1" interface. Both paths are connected to a grey box at the bottom labeled "Shared O-RU" via "M-Plane" interfaces. A bracket on the left side of the diagram, spanning from the "O-CU SOH" level down to the "Shared O-RU" level, is labeled "M-Plane OAM config for Hybrid Mode only". To the right of the "O-CU SRO" box, there are three dots followed by the text "Additional SROs". Similarly, to the right of the "O-DU SRO" box, there are three dots followed by the text "Additional SROs". + +Figure 4.2-1 Security Architecture for Shared O-RU Options 1 and 2 + +Figure 4.2-1 Security Architecture for Shared O-RU Options 1 and 2 + +![Figure 4.2-2 Security Architecture for Shared O-RU Options 3 and 4](63be4a407ba9b530c954ef3016b87aab_img.jpg) + +This diagram illustrates the security architecture for Shared O-RU Options 3 and 4. At the top, there are two green boxes: "SMO SOH" and "SMO SRO", with three dots to the right of "SMO SRO". Below them, two vertical paths are shown. The left path consists of a blue box "O-CU SOH" connected to an orange box "O-DU SOH" via an "F1" interface. The right path consists of a blue box "O-CU SRO" connected to an orange box "O-DU SRO" via an "F1" interface. Both paths are connected to a grey box at the bottom labeled "Shared O-RU" via "M-Plane" interfaces. A bracket on the left side of the diagram, spanning from the "O-CU SOH" level down to the "Shared O-RU" level, is labeled "M-Plane OAM config for Hybrid Mode only". To the right of the "O-CU SRO" box, there are three dots followed by the text "Additional SROs". Similarly, to the right of the "O-DU SRO" box, there are three dots followed by the text "Additional SROs". + +Figure 4.2-2 Security Architecture for Shared O-RU Options 3 and 4 + +Figure 4.2-2 Security Architecture for Shared O-RU Options 3 and 4 + +![Figure 4.2-3 Security Architecture for Shared O-RU Options 5. This diagram shows a central NHC (Network Health Controller) block. It connects via O1 interfaces to a column of SMO SOH (Service Based Interface) blocks, which then connect via O1 to a column of O-CU SOH (Control Plane) blocks. These O-CU SOH blocks connect via F1 interfaces to a column of O-DU SOH (Data Plane) blocks. All O-DU SOH blocks connect via M-Plane interfaces to a Shared O-RU block. Dotted lines indicate 'Additional SROs' for each level.](85d29166836161773bbb9ab4e9040300_img.jpg) + +Figure 4.2-3 Security Architecture for Shared O-RU Options 5. This diagram shows a central NHC (Network Health Controller) block. It connects via O1 interfaces to a column of SMO SOH (Service Based Interface) blocks, which then connect via O1 to a column of O-CU SOH (Control Plane) blocks. These O-CU SOH blocks connect via F1 interfaces to a column of O-DU SOH (Data Plane) blocks. All O-DU SOH blocks connect via M-Plane interfaces to a Shared O-RU block. Dotted lines indicate 'Additional SROs' for each level. + +**Figure 4.2-3 Security Architecture for Shared O-RU Options 5** + +NOTE: NHC is not an agreed upon function in the O-RAN architecture + +![Figure 4.2-4 Security Architectures for Shared O-RU Resiliency. This figure contains two diagrams. The left diagram, titled 'Security Architecture for Shared O-RU Resiliency with Options 1 and 2', shows an SMO SOH block connected via O1 to multiple O-CU SOH blocks. These connect via F1 to O-DU-1 SOH (Active) and O-DU-2 SOH (Standby) blocks, which then connect via M-Plane to a Shared O-RU block. A label 'M-Plane OAM config (for Hybrid Mode Only)' points to the O1 connections. The right diagram, titled 'Security Architecture for Shared O-RU Resiliency with Options 3 and 4', shows two SMO SRO blocks connected via O1 to O-CU SOH blocks, which connect via F1 to O-DU-1 SOH (Active) and O-DU-2 SOH (Standby) blocks, which then connect via M-Plane to a Shared O-RU block. A label 'M-Plane OAM config (for Hybrid Mode Only)' points to the O1 connections. Dotted lines indicate 'Additional SROs'.](6e654bfec2c61f0bddc774115f6b5c24_img.jpg) + +Figure 4.2-4 Security Architectures for Shared O-RU Resiliency. This figure contains two diagrams. The left diagram, titled 'Security Architecture for Shared O-RU Resiliency with Options 1 and 2', shows an SMO SOH block connected via O1 to multiple O-CU SOH blocks. These connect via F1 to O-DU-1 SOH (Active) and O-DU-2 SOH (Standby) blocks, which then connect via M-Plane to a Shared O-RU block. A label 'M-Plane OAM config (for Hybrid Mode Only)' points to the O1 connections. The right diagram, titled 'Security Architecture for Shared O-RU Resiliency with Options 3 and 4', shows two SMO SRO blocks connected via O1 to O-CU SOH blocks, which connect via F1 to O-DU-1 SOH (Active) and O-DU-2 SOH (Standby) blocks, which then connect via M-Plane to a Shared O-RU block. A label 'M-Plane OAM config (for Hybrid Mode Only)' points to the O1 connections. Dotted lines indicate 'Additional SROs'. + +**Figure 4.2-4 Security Architectures for Shared O-RU Resiliency** + +## 4.3 Interfaces + +The following interfaces, as shown in Figures 4.2-1, 4.2-2, and 4.2-3, are considered in this phase of the Shared O-RU security analysis: + +- ASSET-C-22: O1 +- ASSET-C-24: OFH M-Plane: OAM Config and Carrier Config + +New interfaces for Shared O-RU currently in specifications development will be considered in a later phase of the security analysis. This includes Fast Dynamic Scheduling between Host and Tenant O-DUs and Slow Dynamic Scheduling between Host and Tenant SMOs. + +## 4.4 Information + +The following Shared O-RU information and data should be considered in a risk analysis: + +- O1 Data + - ASSET-D-03: O1 Critical management plane data + - ASSET-D-09: O1 Informational data +- M-Plane Data + - ASSET-D-02: Critical Management Plane Data + - ASSET-D-18: O-RAN network function configuration data + - ASSET-D-24: Netconf Data Stores + - ASSET-D-25: O-RAN Analog Training or Test Data +- Secret Stores + - ASSET-D-16: X.509 certificates + - ASSET-D-17: Private keys + - ASSET-D-19: Cryptographic Keys (such as session keys for, e.g., IPsec, MACsec, ...) + - ASSET-D-20: Administrator credentials (passwords and tokens) + - ASSET-D-32: Cryptographic keys used during secure boot, for encryption/decryption, etc. +- Service Account Management Data + - ASSET-D-yy-new1: Credentials (Services) +- User Account Management Data + - ASSET-D-20: Credentials (Administrators) +- PII + - ASSET-D-30: O-RAN specific UE IDs + - ASSET-D-yy-new3: Sensitive Information (e.g., public IP address, ...) +- Event logs + - ASSET-D-29: Security Event Log Files + +- Trusted Environment + - ASSET-D-yy-new2: Trusted Environment +- CUS-plane Data + - ASSET-D-04: Open Fronthaul Control-plane (C-Plane) data + - ASSET-D-05: Open Fronthaul User-plane (U-Plane) data + - ASSET-D-01: Open Fronthaul Synchronization-plane (S-Plane) data + +Asset identifier with a number indicates that the asset has been identified in the O-RAN Threat Modelling and Risk Assessment document [i.6]. Inclusion of an asset identifier ASSET-X-yy-new indicates the asset has not yet been added to [i.6]. + +# --- 5 Threats + +## 5.1 Threat Model + +The STRIDE model is used to classify threats: + +1. S - Spoofing identity. An application or program can masquerade as another to gain advantages not typically allowed for that program. +2. T - Tampering with data. This involves the malicious modification of data, including making unauthorized changes to a database and alteration of data as it flows between computers. +3. R - Repudiation. A user or program refuses the authenticity of a good or reasonable command or action. +4. I - Information disclosure. This involves the exposure of information to individuals with unauthorized access to it. For example, users gain the ability to read a file that they normally would not have been granted access to, or an intruder can read data in transit between computers. +5. D - Denial of service. These attacks deny service to valid users, such as making a website unavailable or unusable by flooding it with illegitimate requests to keep legitimate users without access. +6. E - Elevation of privileges. An unauthorized user gains privileged rights to access previously no granted to compromise or destroy the system, such as a change in membership. + +| Threat types | Impact types | +|------------------------|-----------------| +| Spoofing | Authenticity | +| Tampering | Integrity | +| Repudiation | Non-repudiation | +| Information disclosure | Confidentiality | +| Denial of Service | Availability | +| Elevation of Privilege | Authorization | + +## 5.2 Threat Template + +Template to present the threat characteristics: + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------| +| Threat ID | | +| Threat title | | +| Threat description | | +| Threat type | Spoofing
    Tampering
    Repudiation
    Information disclosure
    Denial of Service
    Elevation of Privilege | +| Vulnerabilities | | +| Impact type | Authenticity
    Integrity
    Non-repudiation
    Confidentiality
    Availability
    Authorization | +| Affected Assets | | + +## 5.3 Potential Threats and Exploits + +A threat analysis is facilitated by an understanding of potential threats, as identified by the Cloud Security Alliance (CSA) and the Open Web Application Security Project (OWASP). + +The OWASP Top 10 Web Application Security Risks [i.12] was updated in 2021 to include the following: + +- A01:2021 Broken Access Control +- A02:2021 Cryptographic Failure +- A03:2021 Injection (including Cross-Site Scripting) +- A04:2021 Insecure Design +- A05:2021 Security Misconfiguration +- A06:2021 Vulnerable and Outdated Components +- A07:2021 Identification and Authentication Failures +- A08:2021 Software and Data Integrity Failures (including Insecure Deserialization) +- A09:2021 Security Logging and Monitoring Failures +- A10:2021 Server-Side Request Forgery + +The CSA Top Threats to Cloud in 2019 was labelled the “Egregious Eleven” [i.13], as listed below: + +1. Data Breaches +2. Misconfiguration and Inadequate Change Control +3. Lack of Cloud Security Architecture and Strategy +4. Insufficient Identity, Credential, Access, and Key Management +5. Account Hijacking +6. Insider Threat +7. Insecure Interfaces and APIs +8. Weak Control plane +9. Metastructure and Applistructure Failures +10. Limited Cloud Usage Visibility +11. Abuse and Nefarious Uses of Cloud Services + +The CSA updated its list of top threats to cloud in 2022 and renamed it the “Pandemic Eleven” [i.14], as listed below: + +1. Insufficient Identity, Credential, Access and Key Management, Privileged Accounts +2. Insecure Interfaces and APIs +3. Misconfiguration and Inadequate Change Control +4. Lack of Cloud Security Architecture and Strategy +5. Insecure Software Development +6. Unsecure Third-Party Resources +7. System Vulnerabilities +8. Accidental Cloud Data Disclosure +9. Misconfiguration and Exploitation of Serverless and Container Workloads +10. Organized Crime, Hackers & APT +11. Cloud Storage Data Exfiltration + +## 5.4 Shared O-RU Threats + +The security risks associated with the Shared O-RU are due to: + +1. resource sharing in a multi-tenant environment +2. interworking between host and tenant network functions +3. interfaces between Shared O-RU and other O-RAN functions + +The Shared O-RU threat analysis considers the threats listed in clause 5.3 that are relevant to O-RAN and Shared O-RU. The following threats to Shared O-RU have been identified and will be analyzed in clause 6 – Threat Analysis. + +### Threats due to Multi-Tenancy + +- O-DU Host access to O-DU Tenant through Shared O-RU +- O-DU Tenant access to O-DU Host through Shared O-RU +- SMO Host access to SMO Tenant +- SMO Tenant access to SMO Host + +### Threats at Shared O-RU functions + +- Parameter conflicts at Shared O-RU +- Privilege levels for authorization to data and processes in O-RU, O-DU, and SMO +- Escalation of privilege at NHC + +### Threats to Shared O-RU interfaces + +- Untrusted peering between Shared O-RU and O-DU +- Insecure APIs +- Message flooding +- Unprotected data in transit + +# 6 Threat Analysis + +Threat Analysis tables are provided for each of the identified Shared O-RU threats in the subsections below. The Shared O-RU Threats are classified into the following 7 threat groups: + +- Lateral Movement Between Network Functions +- User Access Threats +- Data Access Threats +- Availability Threats +- Configuration Threats +- Neutral Host Controller Threats +- Resiliency + +Table 6-1 summarizes the identified threats for each of the Shared O-RU threat groups. The threat analysis considers a zero trust architecture (ZTA) for which (i) micro-perimeters are established for each asset and (ii) there is no implicit trust granted to assets or users [i.8]. Shared O-RU assets, as discussed in the Functions, Interfaces, and Information asset groups in clause 4- Assets, are considered for the threat analysis. The threat analysis was performed on the five architectural options being considered for deployment of Shared O-RU [i.3], which allow use of M-Plane Hybrid or Hierarchical mode and optional use of a Neutral Host Controller (NHC). + +Table 6-1 summarizes the identified threats for each of the Shared O-RU threat groups. This may not be an exhaustive list and may be expanded in future versions of this Technical Report. + +Use of the term “MNO Tenant” or “Tenant” refers to a “Shared Resource Operator (SRO)” as defined in O-RAN ALLIANCE TS: “Management Plane Specification.[i.20]. + +Table 6-1 Shared O-RU Threats + +| Threat-Id | Threat Description (Brief) | +|---------------------------------------------------|--------------------------------------| +| Lateral Movement Between Network Functions | | +| T-SharedORU-01 | O-DU Tenant accesses O-DU Host | +| T-SharedORU-02 | O-DU Host accesses O-DU Tenant | +| T-SharedORU-03 | O-DU Tenant accesses O-DU Tenant | +| T-SharedORU-04 | Password Attack on OFH M-Plane | +| T-SharedORU-05 | Untrusted peering to O-DU | +| T-SharedORU-06 | Untrusted peering to the Shared O-RU | +| T-SharedORU-07 | Untrusted peering to the SMO | +| T-SharedORU-08 | SMO Tenant accesses SMO Host | +| T-SharedORU-09 | SMO Host accesses SMO Tenant | +| T-SharedORU-10 | O-DU Host accesses O-CU Tenant | +| T-SharedORU-11 | O-DU Tenant accesses O-CU Host | +| T-SharedORU-12 | O-DU Tenant accesses O-CU Tenant | +| T-SharedORU-13 | SMO Host accesses O-CU Tenant | + +| | | +|----------------------------------------|------------------------------------------------------------------------| +| T-SharedORU-14 | SMO Tenant accesses O-CU Host | +| User Access Threats | | +| T-SharedORU-15 | Physical port access to Shared O-RU Host/Tenant | +| T-SharedORU-16 | Physical port access to O-DU Host/Tenant | +| T-SharedORU-17 | Physical port access to O-CU Host/Tenant | +| T-SharedORU-18 | Malicious User Login Attempt to SMO Host/Tenant | +| T-SharedORU-19 | Malicious User Login Attempt to O-CU Host/Tenant | +| T-SharedORU-20 | Malicious User Login Attempt to O-DU Host/Tenant | +| T-SharedORU-21 | Malicious User Login Attempt to Shared O-RU Host/Tenant | +| Data Access Threats | | +| T-SharedORU-22 | Unauthorized internal threat actor gains access to data in Shared O-RU | +| T-SharedORU-23 | Unauthorized external threat actor gains access to data in Shared O-RU | +| T-SharedORU-24 | Exposure of data at rest at Shared O-RU | +| T-SharedORU-25 | Exposure of Shared O-RU data at rest at SMO | +| T-SharedORU-26 | Exposure of Shared O-RU data at rest at O-DU | +| T-SharedORU-27 | Exposed data in transit between Shared O-RU and O-DU Host/Tenant | +| T-SharedORU-28 | Exposed data in transit between Shared O-RU and SMO Host/Tenant | +| T-SharedORU-43 | Eavesdropping of unprotected CUSM-plane data within shared O-RU | +| Availability Threats | | +| T-SharedORU-29 | Modify/Delete OFH C-Plane messages | +| T-SharedORU-30 | Clock hijacking on OFH S-Plane | +| T-SharedORU-31 | Parameter conflicts at Shared O-RU | +| T-SharedORU-32 | Volumetric DDoS attack from O-DU targeting Shared O-RU | +| T-SharedORU-33 | Volumetric DDoS attack from SMO targeting Shared O-RU | +| T-SharedORU-34 | Volumetric DDoS attack targeting O-DU | +| T-SharedORU-35 | Shared O-RU initialization hijacking by DHCP compromise | +| T-SharedORU-36 | Shared O-RU M-plane hijacking by DNS compromise | +| Configuration Threats | | +| T-SharedORU-37 | Misconfiguration of MNO Host Role | +| T-SharedORU-38 | Incorrect Assignment of Spectrum Resources | +| T-SharedORU-39 | Chain of Trust in a Multi-Tenant Environment | +| T-SharedORU-40 | Hijack of MNO Host Role | +| T-SharedORU-41 | Inability of SMO to Revoke Host Privileges from a Malicious Tenant | +| T-SharedORU-42 | Misuse of "sudo" privileges | +| T-SharedORU-55 | Set Incorrect Array-Carrier configuration on O-DU (Standby) | +| T-SharedORU-56 | Modify Array-Carrier pre-configuration on Shared O-RU | +| T-SharedORU-57 | Modify/Inject M-Plane messages with Array-Carrier configuration | +| Neutral Host Controller Threats | | +| T-SharedORU-44 | SMO peers with untrusted NHC | +| T-SharedORU-45 | Shared O-RU peers with untrusted NHC | +| T-SharedORU-46 | NHC peers with untrusted entities | +| T-SharedORU-47 | Malicious actor at the NHC can access information on the SMO | +| T-SharedORU-48 | Malicious actor at the NHC can access information on the Shared O-RU | + +| T-SharedORU-49 | NHC is source of DDoS attack on SMO | +|--------------------|---------------------------------------------| +| T-SharedORU-50 | NHC is source of DDoS attack on Shared O-RU | +| T-SharedORU-51 | Shared O-RU data exposure at NHC | +| Resiliency Threats | | +| T-SharedORU-52 | Thrashing O-DU Failovers | +| T-SharedORU-53 | Dual (Dueling) Active O-DUs | +| T-SharedORU-54 | Modify/Inject O1 messages at the SMO | + +## 6.1 Lateral Movement Between Network Functions + +This section provides threat analysis tables for threats to access between Shared O-RU network functions. + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-01 | +| Threat title | O-DU Tenant accesses O-DU Host | +| Threat description | The O-DU Tenant accesses the O-DU Host through the Shared O-RU. Weak authentication can be exploited by a tenant to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Host | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-02 | +| Threat title | O-DU Host accesses O-DU Tenant | +| Threat description | The O-DU Host accesses the O-DU Tenant through the Shared O-RU. Weak authentication can be exploited by a host to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Tenant | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-03 | +| Threat title | O-DU Tenant accesses O-DU Tenant | +| Threat description | An O-DU Tenant accesses another O-DU Tenant through the Shared O-RU supporting multiple tenants. Weak authentication can be exploited by a tenant to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Tenant | + +| | | +|---------------------|--------------------------------| +| Threat ID | T-SharedORU-04 | +| Threat title | Password Attack on OFH M-Plane | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat description | Use of single-factor authentication with password on the Open Fronthaul M-Plane can be exploited by an internal malicious actor to gain access to the Shared O-RU. The attack can be a brute-force attack or stolen password. There is increased risk of password attack in a multi-tenant environment. The internal malicious actor may be the MNO Host, a MNO Tenant (SRO), or a 3rd-party. [i.9] | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | Shared O-RU, O-DU Host, O-DU Tenant | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-05 | +| Threat title | Untrusted peering to O-DU | +| Threat description | Attacker exploits weak authentication on the O-DU to establish a session with a malicious app masquerading as a Shared O-RU. From the O-DU, a malicious actor can move laterally across Shared O-RUs and northbound to the O-CU and SMO. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Host, O-DU Tenant | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-06 | +| Threat title | Untrusted peering to the Shared O-RU | +| Threat description | Attacker exploits weak authentication on the Shared O-RU to establish session with a malicious app masquerading as a O-DU Host or O-DU Tenant | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | Shared O-RU | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-07 | +| Threat title | Untrusted peering to the SMO | +| Threat description | Attacker exploits weak authentication on the SMO to establish session with a malicious app masquerading as a Shared O-RU. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO Host, SMO Tenant | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-08 | +| Threat title | SMO Tenant accesses SMO Host | +| Threat description | The SMO Tenant accesses the SMO Host through the Shared O-RU. Weak authentication can be exploited by a tenant to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | + +| | | +|-----------------------|----------| +| Affected Asset | SMO Host | +|-----------------------|----------| + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-09 | +| Threat title | SMO Host accesses SMO Tenant | +| Threat description | The SMO Host accesses the SMO Tenant through the Shared O-RU. Weak authentication can be exploited by a host to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO Tenant | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-10 | +| Threat title | O-DU Host accesses O-CU Tenant | +| Threat description | The O-DU Host accesses the O-CU Tenant through the Shared O-RU. Weak authentication can be exploited by a host to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Tenant | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-11 | +| Threat title | O-DU Tenant accesses O-CU Host | +| Threat description | The O-DU Tenant accesses the O-CU Host through the Shared O-RU. Weak authentication can be exploited by a tenant to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Host | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-12 | +| Threat title | O-DU Tenant accesses O-CU Tenant | +| Threat description | The O-DU Tenant accesses another O-CU Tenant through the Shared O-RU supporting multiple tenants. Weak authentication can be exploited by a tenant to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Tenant | + +| | | +|------------------|----------------| +| Threat ID | T-SharedORU-13 | +|------------------|----------------| + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | SMO Host accesses O-CU Tenant | +| Threat description | The SMO Host accesses the O-CU Tenant through the Shared O-RU. Weak authentication can be exploited by a host to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Tenant | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-14 | +| Threat title | SMO Tenant accesses O-CU Host | +| Threat description | The SMO Tenant accesses the O-CU Host through the Shared O-RU. Weak authentication can be exploited by a tenant to move laterally across the deployment. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Host | + +## 6.2 User Access Threats + +This section provides threat analysis tables for user access threats to Shared O-RU. + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-15 | +| Threat title | Physical port access to Shared O-RU Host/Tenant | +| Threat description | A host, tenant, or third-party gains physical port connectivity to the Shared O-RU. With this physical access the actor exploits weak physical layer authentication to gain access to the Shared O-RU. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-16 | +| Threat title | Physical port access to O-DU Host/Tenant | +| Threat description | A host, tenant, or third-party gains physical port connectivity to a O-DU Host or O-DU Tenant. With this physical access the actor exploits weak physical layer authentication to gain access to the O-DU. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Host, O-DU Tenant | + +| | | +|------------------|----------------| +| Threat ID | T-SharedORU-17 | +|------------------|----------------| + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat title | Physical port access to O-CU Host/Tenant | +| Threat description | A host, tenant, or third-party gains physical port connectivity to a O-CU Host or O-CU Tenant. With this physical access the actor exploits weak physical layer authentication to gain access to the O-CU. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Host, O-CU Tenant | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-18 | +| Threat title | Malicious User Login Attempt to SMO Host/Tenant | +| Threat description | The attacker attempts to access the SMO Host or SMO tenant through a management interface. The attacker may be an internal or external actor. Weak account management and/or authentication can be exploited to gain access to move laterally across the deployment for nefarious purposes such as reconnaissance or damage. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | SMO Host, SMO Tenant | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-19 | +| Threat title | Malicious User Login Attempt to O-CU Host/Tenant | +| Threat description | The attacker attempts to access the O-CU Host or O-CU Tenant through a management interface. The attacker may be an internal or external actor. Weak account management and/or authentication can be exploited to gain access to move laterally across the deployment for nefarious purposes such as reconnaissance or damage. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-CU Host, O-CU Tenant | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-20 | +| Threat title | Malicious User Login Attempt to O-DU Host/Tenant | +| Threat description | The attacker attempts to access the O-DU Host or O-DU Tenant through a management interface. The attacker may be an internal or external actor. Weak account management and/or authentication can be exploited to gain access to move laterally across the deployment for nefarious purposes such as reconnaissance or damage. | +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | O-DU Host, O-DU Tenant | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-21 | +| Threat title | Malicious User Login Attempt to Shared O-RU Host/Tenant | +| Threat description | The attacker attempts to access the O-RU Host or O-RU Tenant through a management interface. The attacker may be an internal or external actor. Weak account management and/or authentication can be exploited to gain access to move laterally across the deployment for nefarious purposes such as reconnaissance or damage. | + +| | | +|----------------|--------------------------------------| +| Threat type | Spoofing | +| Impact type | Authenticity | +| Affected Asset | Shared O-RU Host, Shared O-RU Tenant | + +## 6.3 Data Access Threats + +This section provides threat analysis tables for threats to Shared O-RU data access. + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-22 | +| Threat title | Unauthorized internal threat actor gains access to data in Shared O-RU | +| Threat description | Malicious internal threat actor exploits compromised credentials or weak or misconfigured authorization to gain access to view or modify sensitive data-at-rest or data-in-use in the Shared O-RU. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-23 | +| Threat title | Unauthorized external threat actor gains access to data in Shared O-RU | +| Threat description | Malicious external threat actor exploits compromised credentials or weak or misconfigured authorization to gain access to view or modify sensitive data-at-rest or data-in-use in the Shared O-RU. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-24 | +| Threat title | Data exposure at Shared O-RU | +| Threat description | Data-at-rest or data-in-use on the Shared O-RU is exposed to a tenant. Attacker exploits weak confidentiality protection to view data owned by the MNO Host or a MNO Tenant. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-25 | +| Threat title | Shared O-RU data exposure at SMO | +| Threat description | Data-at-rest or data-in-use on the SMO related to a Shared O-RU is exposed to an unauthorized tenant / SMO user. Attacker exploits weak confidentiality protection to view data owned by the MNO Host or a MNO Tenant of a shared O-RU. | + +| | | +|----------------|------------------------| +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-26 | +| Threat title | Shared O-RU data exposure at O-DU | +| Threat description | Data-at-rest or data-in-use on the O-DU related to a Shared O-RU is exposed to an unauthorized tenant. Attacker exploits weak confidentiality protection to view data owned by the MNO Host or a MNO Tenant of a shared O-RU. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-27 | +| Threat title | Exposed data in transit between Shared O-RU and O-DU Host/Tenant | +| Threat description | Data-in-transit between the Shared O-RU and an O-DU Host or O-DU Tenant could be exposed to another MNO or malicious threat actor. Weak confidentiality protection of data-in-transit allows the host, tenant, or actor to view intercepted data owned by the MNO Host or a MNO Tenant. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU, M-Plane, CUS-Plane | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-28 | +| Threat title | Exposed data in transit between Shared O-RU and SMO Host/Tenant | +| Threat description | Data-in-transit between the Shared O-RU and a SMO Host or SMO Tenant could be exposed to another MNO or malicious threat actor. Weak confidentiality protection of data-in-transit allows the host, tenant, or actor to view intercepted data owned by the MNO Host or a MNO Tenant. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU, O1 | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-43 | +| Threat title | Eavesdropping of unprotected CUSM-plane data within shared O-RU | +| Threat description | The SMO assigns the role of Host and MNO SRO(s). The tenant maliciously or intended is obtaining access to transport protocol stack and is therefore able to eavesdrop sensitive data from neighbor tenants and the host. The tenant may have capability for sniffing/capturing of CUSM-plane data. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | + +| | | +|----------------|-------------| +| Affected Asset | Shared O-RU | +|----------------|-------------| + +## 6.4 Availability Threats + +This section provides threat analysis tables for availability threats to Shared O-RU. + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-29 | +| Threat title | Modify/Delete OFH C-Plane messages | +| Threat description | A MNO Host, MNO Tenant, or 3 rd -party, maliciously modifies or deletes control plane messages on the OFH C-Plane between the Shared O-RU and Host O-DU or Tenant O-DU. This type of integrity attack can also result in an availability attack. | +| Threat type | Tampering | +| Impact type | Integrity, Availability | +| Affected Asset | Shared O-RU, O-DU Host, O-DU Tenant, CUS-Plane | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-30 | +| Threat title | Clock hijacking on OFH S-Plane | +| Threat description | A MNO Host, MNO Tenant, or 3 rd -party maliciously takes the role of Grand Master clock on the S-Plane to degrade performance on the U-Plane. This type of authorization exploit can also result in an availability attack. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization, Availability | +| Affected Asset | Shared O-RU, O-DU Host, O-DU Tenant, CUS-Plane | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-31 | +| Threat title | Parameter conflicts at Shared O-RU | +| Threat description | O-DU Host and O-DU Tenants may force conflicting parameter settings at the Shared O-RU that can degrade performance or cause an outage. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Shared O-RU | + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-32 | +| Threat title | Volumetric DDoS attack from O-DU targeting Shared O-RU | +| Threat description | An O-DU Host or O-DU Tenant maliciously or unintentionally sends a high-rate of malformed, mis-sequenced, invalid, or valid packets over the Open Fronthaul interface to the Shared O-RU. This kind of attack can cause a Denial of Service on the Shared O-RU. | +| Threat type | Denial of Service | +| Impact type | Availability | + +| | | +|----------------|---------------------------------| +| Affected Asset | Shared O-RU, M-Plane, CUS-Plane | +|----------------|---------------------------------| + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-33 | +| Threat title | Volumetric DDoS attack from SMO targeting Shared O-RU | +| Threat description | The SMO Host maliciously or unintentionally sends a high-rate of malformed, mis-sequenced, invalid, or valid packets over the Open Fronthaul interface to the Shared O-RU. This kind of attack can cause a Denial of Service on the Shared O-RU. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Shared O-RU, O1 | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-34 | +| Threat title | Volumetric DDoS attack targeting O-DU | +| Threat description | Shared O-RU maliciously or unintentionally sends a high-rate of malformed, mis-sequenced, invalid, or valid packets over the Open Fronthaul interface to the O-DU Host or O-DU Tenant. This kind of attack can cause a Denial of Service on the O-DU. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | O-DU Host, O-DU Tenant, CUS-Plane, M-Plane | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-35 | +| Threat title | Shared O-RU initialization hijacking by DHCP compromise | +| Threat description | Shared O-RU bootup and initialization sequence depends on parameters passed to it via DHCP options. An attacker can compromise DHCP server and use it to hijack the O-RU and prevent Shared O-RU from reaching carrier-active state. This kind of attack can cause a Denial of Service on the shared O-RU. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Shared O-RU | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-36 | +| Threat title | Shared O-RU M-plane hijacking by DNS compromise | +| Threat description | Shared O-RU M-plane initialization depends on DNS, if FQDN is returned as the NETCONF controller of shared O-RU during its initialization. The name resolution of FQDN can be manipulated by an attacker using a compromised DNS server and prevent Shared O-RU from reaching carrier-active state due to unavailability of carrier configuration. This kind of attack can cause a Denial of Service on the shared O-RU. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Shared O-RU | + +## 6.5 Configuration Threats + +This section provides threat analysis tables for configuration threats to Shared O-RU. + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-37 | +| Threat title | Misconfiguration of MNO Host Role | +| Threat description | The SMO assigns the role of MNO Host and MNO SRO(s). The assignment of Host role to the wrong SRO can expose data. A threat actor could exploit an incorrectly assigned role of Host to control function of the Shared O-RU | +| Threat type | Information Disclosure, Denial of Service | +| Impact type | Confidentiality, Availability | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-38 | +| Threat title | Incorrect Assignment of Spectrum Resources | +| Threat description | Shared O-RU is responsible for assignment and control of spectrum resources, including component carrier and frequencies within a carrier. Tenant access to the wrong resources, due to malicious intent or could be exploited to gain access to information. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-39 | +| Threat title | Chain of Trust in a Multi-Tenant Environment | +| Threat description | The Chain of Trust is a certificate-based chain used to authenticate an entity. The Chain of Trust is established by validating the hardware and software for the entity up to the root certificate as the trust anchor. The Shared O-RU mutually authenticates O-DU Hosts and O-DU Tenants. Certificates from O-DU tenants must be validated as trustworthy. Malicious actors can exploit untrustworthy certificates to gain access to the Shared O-RU. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | Shared O-RU, O-DU Host, O-DU Tenant, O-CU Host, O-CU Tenant, SMO Host, SMO Tenant | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-40 | +| Threat title | Hijack of MNO Host Role | +| Threat description | The SMO assigns the role of MNO Host and MNO SRO(s). A tenant may maliciously or unintentionally obtain the host role. The elevation of privilege would enable the tenant, acting as host, to have authorized access on the Shared O-RU to sensitive data, credentials, and system privileges. | +| Threat type | Elevation of Privilege | + +| | | +|-----------------------|---------------| +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-41 | +| Threat title | Inability of SMO to Revoke Host Privileges from a Malicious Tenant | +| Threat description | A malicious tenant obtains the role of Host or MNO SRO. The role enables the malicious tenant to perform actions such as obtaining sensitive data and launching DoS attack. Due to static assignment of privileges, the SMO cannot revoke Host privileges from the malicious tenant. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-42 | +| Threat title | Misuse of “sudo” privileges | +| Threat description | A malicious tenant obtains the privileges of a Host or MNO SRO. These privileges enable the malicious tenant to perform actions such as obtaining sensitive data and launching DoS attack. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-55 | +| Threat title | Set Incorrect Array-Carrier configuration on O-DU (Standby) | +| Threat description | Threat actor spoofs SMO to set or modify the pre-configured array-carrier configuration on the O-DU in Standby state. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | O-DU-1, O-DU-2, O1 interface | + +| | | +|---------------------------|----------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-56 | +| Threat title | Modify Array-Carrier pre-configuration on Shared O-RU | +| Threat description | Threat actor can gain access to Shared O-RU to modify its pre-configured array-carrier | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-57 | +| Threat title | Modify/Inject M-Plane messages with Array-Carrier configuration | +| Threat description | Threat actor Modifies/Injects M-Plane messages with Array-Carrier configuration sent to the Shared O-RU. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | Shared O-RU, M-Plane | + +## 6.6 Neutral Host Controller (NHC) Threats + +This section provides threat analysis tables for threats introduced by the NHC. + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-44 | +| Threat title | SMO peers with untrusted NHC | +| Threat description | One of the optional architectures for deployment of Shared O-RU uses a NHC. In this architectural option, the SMO communicates with the Shared O-RU through a NHC. Lack of strong authentication would allow the SMO to peer with an untrusted NHC, which a malicious threat actor could exploit for further attacks. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | SMO Host, SMO Tenant | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-45 | +| Threat title | Shared O-RU peers with untrusted NHC | +| Threat description | One of the optional architectures for deployment of Shared O-RU uses a NHC. In this architectural option, the Shared O-RU communicates with the SMO through a NHC. Lack of strong authentication would allow the Shared O-RU to peer with an untrusted NHC, which a malicious threat actor could exploit for further attacks. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-46 | +| Threat title | NHC peers with untrusted entities | +| Threat description | One of the optional architectures for deployment of Shared O-RU uses a NHC. In this architectural option, the Shared O-RU and SMO communicate through a NHC. Lack of strong authentication would allow the NHC to peer with an untrusted SMO or Shared O-RU, which a malicious threat actor could exploit for further attacks. | +| Threat type | Spoofing | +| Impact type | Authentication | + +| | | +|----------------|-----| +| Affected Asset | NHC | +|----------------|-----| + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-47 | +| Threat title | Malicious actor at the NHC can access information on the SMO | +| Threat description | Without proper authorization controls, a malicious actor who has gained access to the SMO from the NHC could be able to access information on the SMO to view, modify or delete. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | SMO Host, SMO Tenant | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-48 | +| Threat title | Malicious actor at the NHC can access information on the Shared O-RU | +| Threat description | Without proper authorization controls, a malicious actor who has gained access to the Shared O-RU from the NHC could be able to access information on the Shared O-RU to view, modify or delete. | +| Threat type | Elevation of Privilege | +| Impact type | Authorization | +| Affected Asset | Shared O-RU | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-49 | +| Threat title | NHC is source of DDoS attack on SMO | +| Threat description | The NHC maliciously or unintentionally sends a high-rate of malformed, mis-sequenced, invalid, or valid packets over the O1 interface to the SMO. This kind of volumetric attack can cause a Denial of Service on the SMO. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | SMO Host, SMO Tenant | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-50 | +| Threat title | NHC is source of DDoS attack on Shared O-RU | +| Threat description | The NHC maliciously or unintentionally sends a high-rate of malformed, mis-sequenced, invalid, or valid packets over the M-Plane interface to the Shared O-RU. This kind of volumetric attack can cause a Denial of Service on the Shared O-RU. | +| Threat type | Denial of Service | +| Impact type | Availability | +| Affected Asset | Shared O-RU | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-51 | +| Threat title | Shared O-RU data exposure at NHC | +| Threat description | Data-at-rest on the NHC related to a Shared O-RU is exposed to an unauthorized tenant. Attacker exploits weak confidentiality protection to view data owned by the MNO Host or a MNO Tenant of a shared O-RU. | +| Threat type | Information Disclosure | +| Impact type | Confidentiality | +| Affected Asset | Shared O-RU | + +## 6.7 Resiliency Threats + +This section provides threat analysis tables for threats introduced by the O-DU Resiliency use case. + +| | | +|---------------------------|-----------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-52 | +| Threat title | Thrashing O-DU Failovers | +| Threat description | Threat actor spoofs SMO to cause O-DU-1 and O-DU-2 to thrash between Active state and Standby state | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | O-DU, O1 interface | + +| | | +|---------------------------|--------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-53 | +| Threat title | Dual (Dueling) Active O-DUs | +| Threat description | Threat actor spoofs SMO to cause O-DU-1 and O-DU-2 to both be in Active state. | +| Threat type | Spoofing | +| Impact type | Authentication | +| Affected Asset | O-DU, O1 interface | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------| +| Threat ID | T-SharedORU-54 | +| Threat title | Modify/Inject O1 messages at the SMO | +| Threat description | Threat actor spoofs O-DU to modify, inject, flood O1 messages to the SMO to prevent SMO detection of O-DU failure. | +| Threat type | Tampering | +| Impact type | Integrity | +| Affected Asset | SMO, O1 interface | + +# 7 Security Controls + +Industry recommendations for strong security controls are provided from sources such as the OWASP Top 10 Proactive Controls [i.15], Center for Internet Security (CIS) Critical Security Controls [i.16], Cloud Security Alliance (CSA) Cloud Control Matrix (CCM) [i.17], ISO/IEC 27001:2013 Information Security Management System (ISMS) [i.18], NIST SP 800-53r5 Security and Privacy Controls for Information Systems and Organizations [i.19], and Cybersecurity and Infrastructure Security Agency (CISA) Security Guidance for 5G Cloud Infrastructures [i.9]. + +The OWASP Top 10 Proactive Controls are as follow: + +- C1: Define Security Requirements +- C2: Leverage Security Frameworks and Libraries +- C3: Secure Database Access +- C4: Encode and Escape Data +- C5: Validate All Inputs +- C6: Implement Digital Identity +- C7: Enforce Access Controls +- C8: Protect Data Everywhere +- C9: Implement Security Logging and Monitoring +- C10: Handle All Errors and Exceptions + +The CIS Critical Security Controls are as follow: + +- CIS Control 1: Inventory and Control of Enterprise Assets +- CIS Control 2: Inventory and Control of Software Assets +- CIS Control 3: Data Protection +- CIS Control 4: Secure Configuration of Enterprise Assets and Software +- CIS Control 5: Account Management +- CIS Control 6: Access Control Management +- CIS Control 7: Continuous Vulnerability Management +- CIS Control 8: Audit Log Management +- CIS Control 9: Email Web Browser and Protections +- CIS Control 10: Malware Defenses +- CIS Control 11: Data Recovery +- CIS Control 12: Network Infrastructure Management +- CIS Control 13: Network Monitoring and Defense +- CIS Control 14: Security Awareness and Skills Training +- CIS Control 15: Service Provider Management +- CIS Control 16: Application Software Security + +CIS Control 17: Incident Response Management + +CIS Control 18: Penetration Testing + +Relevant controls from the CSA CCM are 2. Application and Interface Security, 5. Cryptography, Encryption, and Key Management, 7. Data Security and Privacy Lifecycle Management, and 10. Identity and Access Management (IAM). + +Relevant controls from ISO/IEC 27001:2013 are 5. Access Controls, 6. Cryptography, and 9. Communications Security. + +Relevant controls from NIST SP 800-53r5 are 1. Access Controls, 16. Risk Assessment, 18. System and Communications Protection, and 19. System and Information Integrity. + +Relevant controls from CISA's Security Guidance are TLS 1.2, or higher, with PKI and X.509 certificates, Multi-Factor Authentication (MFA), Principle of Least Privilege, Continuous Monitoring and Logging, and data confidentiality and protection as components of a zero trust architecture as defined in NIST SP 800-207 [i.8]. + +With consideration of these external sources, the following security controls should be evaluated for the Shared O-RU risk analysis: + +- Control-1: TLS with PKI and X.509 certificates +- Control-2: OAuth 2.0 +- Control-3: IAM (using RBAC, ABAC, PBAC, TBAC) +- Control-4: Principle of Least Privilege +- Control-5: Certificate Management +- Control-6: API Message Integrity Protection and Input Validation +- Control-7: API Message Authentication +- Control-8: Encryption for Data at Rest +- Control-9: Encryption for Data in Motion +- Control-10: Integrity Protection for Data at Rest +- Control-11: Integrity Protection for Data in Motion +- Control-12: Integrity Protection for Data in Use +- Control-13: Digital Signatures +- Control-14: Monitoring and Logging +- Control-15: Alerting +- Control-16: Rate-Limiting +- Control-17: Configuration Validation +- Control-18: Network Segmentation and Traffic Filtering +- Control-19: 802.1X Port-based Network Access Control +- Control-20: Conflict Mitigation +- Control-21: Multi-Factor Authentication (MFA) +- Control-22: Transport Path Separation +- Control-23: Authenticated Resource Release Enforcement + +# 8 Risk Assessment + +This section provides risk assessment tables for each of the identified assets. These tables list the assets, threats, impacts, and possible security controls. + +A malicious actor may be a nation-state adversary, cybercriminal, or employee. In a ZTA, perimeter defenses alone are insufficient. O-RAN deployments, including Shared O-RU, must be protected from untrusted external sources attempting to have access, while also assuming internal threat actors are inside the network with access to its functions and data. Security controls for a ZTA, protecting against external and internal threats, should be implemented through a risk-based approach. A risk analysis calculates risk levels by assessing the threat's Likelihood of attack and the Impact from the attack. External and internal threats are from the perspective of the O-RAN architecture. External Threats are external to the O-RAN and Internal Threats are internal to O-RAN. + +Impact scores can be lowered with consideration of existing security controls. Impact scoring is based upon current security controls. Impact scoring does not consider security controls that may be potentially specified in the future. + +Likelihood scores may be higher when the goal is a ZTA, because external and internal threats must be considered. When likelihood scoring during a risk analysis, it is necessary to consider internal threats performing reconnaissance attacks impacting confidentiality and privacy and attacks causing damage or degrading performance impacting availability. Internal threat actors are less likely to perform damaging attacks that are quickly and easily detected and blocked, but more likely to attempt reconnaissance attacks to collect information. As a result, reconnaissance type attacks can be scored Likelihood = High while damaging/availability attacks can be scored Likelihood = Medium or Low. + +A risk analysis of the Shared O-RU threats is provided in the tables below. A security best practice is to periodically repeat the risk analysis to consider evolving threats and security controls, which may produce an adjusted risk score based upon Impact and Likelihood. + +## 8.1 Lateral Movement Between Network Functions + +Table 8-1. Shared O-RU Risk Analysis - Lateral Movement Between Network Functions + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/
    Likelihood
    Raw Score | Possible Security Controls | Security Control-Id | +|------------------------------------|-------------------------------------|----------------|----------------------------------|--------------------------------------|-------------------------------------------------|---------------------------------| +| ASSET-C-34 | O-DU Host | T-SharedORU-01 | O-DU Tenant accesses O-DU Host | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-35 | O-DU Tenant | T-SharedORU-02 | O-DU Host accesses O-DU Tenant | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-35 | O-DU Tenant | T-SharedORU-03 | O-DU Tenant accesses O-DU Tenant | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-31, ASSET-C-34, ASSET-C-35 | Shared O-RU, O-DU Host, O-DU Tenant | T-SharedORU-04 | Password Attack on OFH M-Plane | Impact = High
    Likelihood = High | mTLS 1.2 or 1.3 with PKI and X.509 certificates | Control-1 | +| ASSET-C-34, ASSET-C-35 | O-DU Host, O-DU Tenant | T-SharedORU-05 | Untrusted peering to O-DU | Impact = High
    Likelihood = High | mTLS 1.2 or 1.3 with PKI and X.509 certificates | Control-1 | + +| | | | | | | | +|------------------------|----------------------|----------------|--------------------------------------|--------------------------------------|-------------------------------------------------|---------------------------------| +| ASSET-C-31 | Shared O-RU | T-SharedORU-06 | Untrusted peering to the Shared O-RU | Impact = High
    Likelihood = High | mTLS 1.2 or 1.3 with PKI and X.509 certificates | Control-1 | +| ASSET-C-38, ASSET-C-39 | SMO Host, SMO Tenant | T-SharedORU-07 | Untrusted peering to the SMO | Impact = High
    Likelihood = High | mTLS 1.2 or 1.3 with PKI and X.509 certificates | Control-1 | +| ASSET-C-38 | SMO Host | T-SharedORU-08 | SMO Tenant accesses SMO Host | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-39 | SMO Tenant | T-SharedORU-09 | SMO Host accesses SMO Tenant | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-37 | O-CU Tenant | T-SharedORU-10 | O-DU Host accesses O-CU Tenant | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-36 | O-CU Host | T-SharedORU-11 | O-DU Tenant accesses O-CU Host | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-37 | O-CU Tenant | T-SharedORU-12 | O-DU Tenant accesses O-CU Tenant | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-37 | O-CU Tenant | T-SharedORU-13 | SMO Host accesses O-CU Tenant | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-36 | O-CU Host | T-SharedORU-14 | SMO Tenant accesses O-CU Host | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | + +## 8.2 User Access Threats + +Table 8-2. Shared O-RU Risk Analysis – User Access Threats + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/
    Likelihood
    Raw Score | Possible Security Controls | Security Control-id | +|------------------------|------------------------|----------------|--------------------------------------------------|--------------------------------------|----------------------------|---------------------| +| ASSET-C-31 | Shared O-RU | T-SharedORU-15 | Physical port access to Shared O-RU | Impact = High
    Likelihood = Medium | 802.1X port-based NAC | Control-19 | +| ASSET-C-34, ASSET-C-35 | O-DU Host, O-DU Tenant | T-SharedORU-16 | Physical port access to O-DU | Impact = High
    Likelihood = Medium | 802.1X port-based NAC | Control-19 | +| ASSET-C-36, ASSET-C-37 | O-CU Host, O-CU Tenant | T-SharedORU-17 | Physical port access to O-CU | Impact = High
    Likelihood = Medium | 802.1X port-based NAC | Control-19 | +| ASSET-C-38, ASSET-C-39 | SMO Host, SMO Tenant | T-SharedORU-18 | Malicious User Login Attempt to SMO Host/Tenant | Impact = High
    Likelihood = High | MFA | Control-21 | +| ASSET-C-36, ASSET-C-37 | O-CU Host, O-CU Tenant | T-SharedORU-19 | Malicious User Login Attempt to O-CU Host/Tenant | Impact = High
    Likelihood = High | MFA | Control-21 | +| ASSET-C-34, ASSET-C-35 | O-DU Host, O-DU Tenant | T-SharedORU-20 | Malicious User Login Attempt to O-DU Host/Tenant | Impact = High
    Likelihood = High | MFA | Control-21 | + +| | | | | | | | +|------------|-------------|----------------|---------------------------------------------------------|------------------------------------|-----|------------| +| ASSET-C-31 | Shared O-RU | T-SharedORU-21 | Malicious User Login Attempt to Shared O-RU Host/Tenant | Impact = High
    Likelihood = High | MFA | Control-21 | +|------------|-------------|----------------|---------------------------------------------------------|------------------------------------|-----|------------| + +## 8.3 Data Access Threats + +Table 8-3. Shared O-RU Risk Analysis – Data Access Threats + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/
    Likelihood
    Raw Score | Possible Security Controls | Security Control-id | +|------------------------------------|---------------------------------|----------------|------------------------------------------------------------------------|--------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------| +| ASSET-C-31 | Shared O-RU | T-SharedORU-22 | Unauthorized internal threat actor gains access to data in Shared O-RU | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-23 | Unauthorized external threat actor gains access to data in Shared O-RU | Impact = High
    Likelihood = Low | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-24 | Exposure of data at rest at Shared O-RU | Impact = High
    Likelihood = High | Data Encryption | Control-8 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-25 | Exposure of Shared O-RU data at rest at SMO | Impact = High
    Likelihood = High | Data Encryption | Control-8 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-26 | Exposure of Shared O-RU data at rest at O-DU | Impact = High
    Likelihood = High | Data Encryption | Control-8 | +| ASSET-C-31, ASSET-C-24, ASSET-C-25 | Shared O-RU, M-Plane, CUS-Plane | T-SharedORU-27 | Exposed data in transit between Shared O-RU and O-DU Host/Tenant | Impact = Low
    Likelihood = Medium | Confidentiality and Integrity protection for data in transit. PDCP is specified on the OFH U-Plane. TLS 1.2/1.3 and SSHv2 are specified for the OFH M-Plane. | Control-9, Control-11 | +| ASSET-C-31, ASSET-D-03 | Shared O-RU, O1 | T-SharedORU-28 | Exposed data in transit between Shared O-RU and SMO Host/Tenant | Impact = Low
    Likelihood = Medium | Confidentiality and Integrity protection for data in transit. TLS 1.2/1.3 and SSHv2 are specified for the O1 interface. | Control-9, Control-11 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-43 | Eavesdropping of unprotected CUSM-plane data within shared O-RU | Impact = High
    Likelihood = High | Transport Path Separation | Control-22 | + +## 8.4 Availability Threats + +Table 8-4. Shared O-RU Risk Analysis – Availability Threats + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/
    Likelihood
    Raw Score | Possible Security Controls | Security Control-id | +|------------------------------------------------|------------------------------------------------|----------------|------------------------------------|--------------------------------------|----------------------------|---------------------| +| ASSET-C-31, ASSET-C-34, ASSET-C-35, ASSET-C-25 | Shared O-RU, O-DU Host, O-DU Tenant, CUS-Plane | T-SharedORU-29 | Modify/Delete OFH C-Plane messages | Impact = High
    Likelihood = Medium | Integrity protection | Control-11 | + +| | | | | | | | +|------------------------------------------------|------------------------------------------------|----------------|---------------------------------------------------------|--------------------------------------|-----------------------------------------------------------|------------------------| +| ASSET-C-31, ASSET-C-34, ASSET-C-35, ASSET-C-25 | Shared O-RU, O-DU Host, O-DU Tenant, CUS-Plane | T-SharedORU-30 | Clock hijacking on OFH S-Plane | Impact = High
    Likelihood = Medium | Message integrity protection, Message authentication | Control-6, Control-7 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-31 | Parameter conflicts at Shared O-RU | Impact = High
    Likelihood = High | Integrity Protection for data-in-use, Conflict mitigation | Control-12, Control-20 | +| ASSET-C-31, ASSET-C-24, ASSET-C-25 | Shared O-RU, M-Plane, CUS-Plane | T-SharedORU-32 | Volumetric DDoS attack from O-DU targeting Shared O-RU | Impact = High
    Likelihood = Medium | Rate-Limiting, Network Segmentation | Control-16, Control-18 | +| ASSET-C-31, ASSET-C-22 | Shared O-RU, O1 | T-SharedORU-33 | Volumetric DDoS attack from SMO targeting Shared O-RU | Impact = High
    Likelihood = Medium | Rate-Limiting, Network segmentation | Control-16, Control-18 | +| ASSET-C-34, ASSET-C-35, ASSET-C-24, ASSET-C-25 | O-DU Host, O-DU Tenant, M-Plane, CUS-Plane | T-SharedORU-34 | Volumetric DDoS attack targeting O-DU | Impact = High
    Likelihood = Medium | Rate-Limiting, Network Segmentation | Control-16, Control-18 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-35 | Shared O-RU initialization hijacking by DHCP compromise | Impact = High
    Likelihood = Medium | API Message Input Validation and Message Authentication | Control-6, Control-7 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-36 | Shared O-RU M-plane hijacking by DNS compromise | Impact = High
    Likelihood = Medium | API Message Input Validation and Message Authentication | Control-6, Control-7 | + +## 8.5 Configuration Threats + +Table 8-5. Shared O-RU Risk Analysis – Configuration Threats + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/ Likelihood Raw Score | Possible Security Controls | Security Control-Id | +|------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------|----------------|----------------------------------------------|--------------------------------------|--------------------------------------------------|-----------------------| +| ASSET-C-31 | Shared O-RU | T-SharedORU-37 | Misconfiguration of MNO Host | Impact = High
    Likelihood = High | Configuration Validation | Control-17 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-38 | Incorrect Assignment of Spectrum Resources | Impact = High
    Likelihood = Medium | Configuration Validation | Control-17 | +| ASSET-C-31, ASSET-C-34, ASSET-C-35, ASSET-C-36, ASSET-C-37, ASSET-C-38, ASSET-C-39 | Shared O-RU, O-DU Host, O-DU Tenant, O-CU Host, O-CU Tenant, SMO Host, SMO Tenant | T-SharedORU-39 | Chain of Trust in a Multi-Tenant Environment | Impact = High
    Likelihood = Medium | Certificate Management, Configuration Validation | Control-5, Control-17 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-40 | Hijack of Host MNO Role | Impact = High
    Likelihood = Medium | Configuration Validation | Control-17 | + +| | | | | | | | +|------------------------|----------------------|----------------|-----------------------------------------------------------------|--------------------------------------|-----------------------------------------------------|----------------------| +| ASSET-C-31 | Shared O-RU | T-SharedORU-41 | Not Released Host Role (Host Role resume) | Impact = High
    Likelihood = High | Authenticated Resource Release Enforcement | Control-23 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-42 | Misuse of “sudo” privileges | Impact = High
    Likelihood = High | IAM | Control-3 | +| ASSET-C-34, ASSET-C-22 | O-DU, O1 | T-SharedORU-55 | Set Incorrect Array-Carrier configuration on O-DU (Standby) | Impact = High
    Likelihood = Medium | mTLS/TLS 1.2 or 1.3 with PKI and X.509 certificates | Control-1 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-56 | Modify Array-Carrier pre-configuration on Shared O-RU | Impact = High
    Likelihood = Medium | IAM with Principle of Least Privilege | Control-3, Control-4 | +| ASSET-C-31, ASSET-C-24 | Shared O-RU, M-Plane | T-SharedORU-57 | Modify/Inject M-Plane messages with Array-Carrier configuration | Impact = High
    Likelihood = Medium | TLS 1.2 or 1.3 | Control-11 | + +## 8.6 Neutral Host Controller Threats + +Table 8-6. Shared O-RU Risk Analysis – Neutral Host Controller Threats + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/ Likelihood Raw Score | Possible Security Controls | Security Control-id | +|------------------------|----------------------|----------------|----------------------------------------------------------------------|--------------------------------------|-------------------------------------------------|---------------------------------| +| ASSET-C-38, ASSET-C-39 | SMO Host, SMO Tenant | T-SharedORU-44 | SMO peers with untrusted NHC | Impact = High
    Likelihood = Medium | mTLS 1.2 or 1.3 with PKI and X.509 certificates | Control-1 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-45 | Shared O-RU peers with untrusted NHC | Impact = High
    Likelihood = Medium | mTLS 1.2 or 1.3 with PKI and X.509 certificates | Control-1 | +| TBA | NHC | T-SharedORU-46 | NHC peers with untrusted entities | Impact = High
    Likelihood = Medium | mTLS 1.2 or 1.3 with PKI and X.509 certificates | Control-1 | +| ASSET-C-38, ASSET-C-39 | SMO Host, SMO Tenant | T-SharedORU-47 | Malicious actor at the NHC can access information on the SMO | Impact = High
    Likelihood = Medium | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-48 | Malicious actor at the NHC can access information on the Shared O-RU | Impact = High
    Likelihood = High | OAuth 2.0, IAM, principle of least privilege | Control-2, Control-3, Control-4 | +| ASSET-C-38, ASSET-C-39 | SMO Host, SMO Tenant | T-SharedORU-49 | NHC is source of DDoS attack on SMO | Impact = High
    Likelihood = Medium | Rate-Limiting, Network Segmentation | Control-16, Control-18 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-50 | NHC is source of DDoS attack on Shared O-RU | Impact = High
    Likelihood = Medium | Rate-Limiting, Network Segmentation | Control-16, Control-18 | +| ASSET-C-31 | Shared O-RU | T-SharedORU-51 | Shared O-RU data exposure at NHC | Impact = High
    Likelihood = High | Data Encryption | Control-8 | + +## 8.7 Resiliency Threats + +Table 8-7. Shared O-RU Risk Analysis – Resiliency Threats + +| Asset-Id | Asset Name | Threat-Id | Threat Description (Brief) | Impact/
    Likelihood
    Raw Score | Possible Security Controls | Security Control-id | +|---------------------------|------------|----------------|--------------------------------------|--------------------------------------|-------------------------------------------------|---------------------| +| ASSET-C-34,
    ASSET-C-22 | O-DU, O1 | T-SharedORU-52 | Thrashing O-DU Failovers | Impact = High
    Likelihood = Medium | mTLS 1.2 or 1.3 with PKI and X.509 certificates | Control-1 | +| ASSET-C-34,
    ASSET-C-22 | O-DU, O1 | T-SharedORU-53 | Dual (Dueling) Active O-DUs | Impact = High
    Likelihood = Medium | mTLS 1.2 or 1.3 with PKI and X.509 certificates | Control-1 | +| ASSET-C-38,
    ASSET-C-22 | SMO, O1 | T-SharedORU-54 | Modify/Inject O1 messages at the SMO | Impact = High
    Likelihood = Medium | TLS 1.2 or 1.3 | Control-11 | + +# 9 Primary Security Issues --- + +The security analysis described in the document has identified the following issues: + +1. New interfaces currently in specifications development process are out of scope in WG11 until further progress is made on the specifications in WG4. These interfaces are Fast Dynamic Scheduling between Host and Tenant O-DUs and Slow Dynamic Scheduling between Host and Tenant SMOs. +2. At this time, Neutral Host Controller (NHC) is not included in the O-RAN architecture, as specified in [i.2]. Security analysis of the NHC may need to be performed again depending upon decisions made by WG1 and WG4. This work item will form normative requirements for the NHC only when WG1 has officially added the NHC to the O-RAN architecture. Until that time there will be no update via CR to add NHC to the following documents: + - *O-RAN Security Requirements Specification* [i.5] + - *O-RAN Security Threat Modeling and Remediation Analysis* [i.6] + - *O-RAN Security Test Specification* [i.7] + +# 10 Recommendations + +The security analysis described in the document has produced the following recommendations: + +1. ZTA requires confidentiality, integrity, and availability protection for network functions and internal interfaces used in the Shared O-RU architecture. Critical security controls for Shared O-RU to comply with a ZTA are: + - mTLS for authentication + - OAuth 2.0 for authorization + - TLS for data in transit + - Encrypt data at rest + - MFA for human user login + - Logging with tenant-awareness + - Role-Based Access Controls (RBAC) for human users to access data +2. Open Fronthaul specification currently allows password-based authentication [i.20]. PKI-based X.509 certificates is recommended for machine-to-machine authentication in a Shared O-RU multi-tenant environment. If SSH is used then asymmetric keys should be used instead of password. +3. In a multi-tenant environment, 802.1X will enforce port-based network access control on all Shared O-RU ethernet-based management interfaces and ethernet-based network interfaces. WG11 should address 802.1X requirements for Shared O-RU with relevant working groups, including WG1, WG4, WG5, and WG6. +4. Shared O-RU is at risk of conflicting parameters from Shared Operator Host (SOH) and Shared Resource Operator (SRO). Conflict mitigation should be implemented. The mechanism for handling conflicting parameters is specified in clause 19.11 “Partitioning of shared O-RU carrier resources” of the O-RAN Open Fronthaul M-Plane specification [i.20]. This clause identifies common Shared O-RU resources shared across SROs, and defines the expectation that logic for resolving conflicting configuration logic resides outside of Shared O-RU. This was based on WG4 technical evaluation of proposals that concluded the Shared O-RU is not the preferred place for resolving conflicting configuration. +5. SRO isolation should be implemented for SOHs and SROs having co-located resources and/or sharing resources. Tenant isolation for Shared O-RU is addressed in clauses 19.3.1, 19.3.3, and 19.6.1 of the O-RAN Open Fronthaul M-Plane specification [i.20]. These clauses introduce new access privilege groups for NETCONF clients that share the O-RU and define how the ‘carrier’ access privilege is used in the context of carrier management on the Open Fronthaul. Each tenant, also called SRO, user account is associated with a sro-id and ‘carrier’ access privilege. +6. For mTLS, both the client and the server need to have access to a Trust Anchor to verify the peer. There are several options for providing this functionality: + +NOTE1: It is the responsibility of the Shared Resource Operator and Shared Operator Host to develop Trust Anchor management processes. Such processes are outside the scope of O-RAN. + +NOTE2: In case the shared O-RU owns several certificates, an O-RU controller might need to send a hint to the shared O-RU in its `ClientHello` message during the TLS handshake indicating which TAs the O-RU controller supports. The extensions used to indicate the client supported TAs are different for TLS 1.2 and TLS 1.3: + +- a. For TLS 1.2, use the `trusted_ca_key` extension; see Section 6 of RFC 6066 ([i.22]). +- b. For TLS 1.3, use the `certificate_authorities` extension; see Section 4.2.4 of RFC 8446 ([i.23]) + +![O-RAN Alliance Logo](d8fafc8adb2e51221a6cc3cd8b363ec4_img.jpg) + +**Option 1: Shared Operator Host PKI issues certificates to each of the Shared Resource Operators:** This is also explained in the WG4 Management Plane Specification ([i.20], Clause 6.2.6.2. The Shared Operator Host issues digital certificates for each of the Shared Resource Operators to enable them to mutually authenticate the TLS connection with the Multi-Operator O-RU. Clients should enrol with previously issued certificates. + +![Figure 10-1: EXAMPLE: Shared Operator Host PKI issues certificates to each of the Shared Resource Operators](0ff93d22c9205a6526977ba1fac22490_img.jpg) + +The diagram illustrates the Shared Operator Hosts PKI issuing certificates to Shared Resource Operators (SRO). It shows a 'Shared Operator Hosts PKI' with a Trust Anchor (TA) node branching to 'Shared O-RU', 'O-RU controller 1', and 'O-RU controller 2' with the label 'Provision TA to all'. It also lists: +a. O-RU controllers "fresh" enroll +b. O-RU controllers use existing certificate to enroll + +Figure 10-1: EXAMPLE: Shared Operator Host PKI issues certificates to each of the Shared Resource Operators + +**Figure 10-1 EXAMPLE: Shared Operator Host PKI issues certificates to each of the Shared Resource Operators** + +As the Shared O-RU only owns a single certificate, the O-RU controller does not need to send a hint to the Shared O-RU (see NOTE2 above). + +**Option 2:** + +**Shared O-RU enrolment only:** the Shared O-RU enrols only with the PKI of its SOH and is installed with the TAs of all SROs. Shared Resource Operators are provisioned with SOHs TA. Option 2 appears to balance the effort to implement and maintain the solution best with the advantages gained. + +![Figure 10-2: EXAMPLE: Shared O-RU enrolment only](547183b9630a9bcfff40dac9dfb214a1_img.jpg) + +The diagram shows the SOH's PKI containing TA pointing to RU. It also shows the 'Shared O-RUs Trust List' containing 'TA' (SOH's TA), 'TA1' (SRO 1's TA), and 'TA2' (SRO 2's TA). SRO 1's Trust List contains 'TA' and 'TA1'. SRO 2's Trust List contains 'TA' and 'TA2'. + +Figure 10-2: EXAMPLE: Shared O-RU enrolment only + +**Figure 10-2 EXAMPLE: Shared O-RU enrolment only** + +As the Shared O-RU only owns a single certificate, the O-RU controller does not need to send a hint to the Shared O-RU (see NOTE2 above). + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 43 + +## Option 3: + +**Shared O-RU and O-RU controllers enrol with a single, separate PKI:** Clients should enrol with previously issued certificates. + +![Figure 10-3: Shared O-RU and O-RU controllers enrol with a single, separate PKI. The diagram shows a network architecture on the left and a PKI enrollment flow on the right. The architecture includes a Shared Operator Host (SOH), Shared Resource Operator (SRO), Shared O-RU, and Network Server, connected via O1, O-FH M-plane, and Common M-plane interfaces. The PKI flow shows a TA provisioning certificates to a Shared O-RU and two O-RU controllers (1 and 2).](d5642012ca098c8488a90421bd661f4f_img.jpg) + +**Separate PKI** + +- a. Shared O-RUs and O-RU controllers “fresh” enroll +- b. Shared O-RUs and O-RU controllers use existing certificate to enroll + +Provision TA to all + +Figure 10-3: Shared O-RU and O-RU controllers enrol with a single, separate PKI. The diagram shows a network architecture on the left and a PKI enrollment flow on the right. The architecture includes a Shared Operator Host (SOH), Shared Resource Operator (SRO), Shared O-RU, and Network Server, connected via O1, O-FH M-plane, and Common M-plane interfaces. The PKI flow shows a TA provisioning certificates to a Shared O-RU and two O-RU controllers (1 and 2). + +**Figure 10-3 EXAMPLE: Shared O-RU and O-RU controllers enrol with a single, separate PKI** + +As the Shared O-RU only owns a single certificate, the O-RU controller does not need to send a hint to the Shared O-RU (see NOTE2 above). + +## Option 4: + +**Cross-certification:** TAs cross-certify, either directly or through a Bridge CA. + +![Figure 10-4: Cross-Certification. The diagram shows the same network architecture as Figure 10-3 on the left. On the right, a PKI flow diagram shows multiple TAs cross-certifying with each other, either directly or through a Bridge CA (BCA). The Shared O-RU and O-RU controllers are shown receiving certificates from these TAs. A dashed line separates the two parts of the diagram.](c3fcb272beed51ee7f9588728a16bb9b_img.jpg) + +No need to provision TAs + +Figure 10-4: Cross-Certification. The diagram shows the same network architecture as Figure 10-3 on the left. On the right, a PKI flow diagram shows multiple TAs cross-certifying with each other, either directly or through a Bridge CA (BCA). The Shared O-RU and O-RU controllers are shown receiving certificates from these TAs. A dashed line separates the two parts of the diagram. + +**Figure 10-4 EXAMPLE: Cross-Certification** + +As the Shared O-RU only owns a single certificate, the O-RU controller does not need to send a hint to the Shared O-RU (see NOTE2 above). + +# Annex A: Shared O-RU All-in-One Architecture + +This section describes the concept of a Shared O-RU architecture as shown in Figure A.1-1. The “All-in-One” architecture represents a single deployment scenario. The Shared O-RU is connected to one or more tenants, while one tenant takes over the host role. + +![Figure A.1-1 Shared O-RU 'All-in-One' Architecture (overview). This diagram illustrates the architecture of a Shared O-RU. At the top, an 'O1 Interface' connects to a dashed box containing 'SMO' (Service Management Orchestrator) and 'SMO (Tenant)'. Inside the 'SMO' box is a 'Common Netconf Client'. Below this, another 'O1 Interface' connects to a 'Neutral Host Controller (opt.)' and an 'O-DU' (Open Distributed Unit). The 'Neutral Host Controller' contains a 'Common Netconf Client'. The 'O-DU' contains 'BB + RRM' and a 'Netconf Client'. To the right, an 'O-DU (Tenant)' also contains 'BB + RRM' and a 'Netconf Client'. A 'Common M-plane' connects the 'Common Netconf Client' in the Neutral Host Controller to a 'Netconf Server' in the 'Shared O-RU'. The 'Netconf Server' also receives 'Carrier Config.' from the 'Netconf Client' in the O-DU and the 'Netconf Client' in the O-DU (Tenant). The 'Shared O-RU' is connected to the 'O-DU' and 'O-DU (Tenant)' via 'CUS-Plane' and 'Carrier Config.' interfaces. A dashed red line labeled 'O-FH M-plane Interface' separates the 'Shared O-RU' from the 'O-DU' and 'O-DU (Tenant)'. The diagram also shows 'Untrusted ORAN' and 'Trusted ORAN' regions.](21fda2f1ee366b5559a3d566408c0115_img.jpg) + +Figure A.1-1 Shared O-RU 'All-in-One' Architecture (overview). This diagram illustrates the architecture of a Shared O-RU. At the top, an 'O1 Interface' connects to a dashed box containing 'SMO' (Service Management Orchestrator) and 'SMO (Tenant)'. Inside the 'SMO' box is a 'Common Netconf Client'. Below this, another 'O1 Interface' connects to a 'Neutral Host Controller (opt.)' and an 'O-DU' (Open Distributed Unit). The 'Neutral Host Controller' contains a 'Common Netconf Client'. The 'O-DU' contains 'BB + RRM' and a 'Netconf Client'. To the right, an 'O-DU (Tenant)' also contains 'BB + RRM' and a 'Netconf Client'. A 'Common M-plane' connects the 'Common Netconf Client' in the Neutral Host Controller to a 'Netconf Server' in the 'Shared O-RU'. The 'Netconf Server' also receives 'Carrier Config.' from the 'Netconf Client' in the O-DU and the 'Netconf Client' in the O-DU (Tenant). The 'Shared O-RU' is connected to the 'O-DU' and 'O-DU (Tenant)' via 'CUS-Plane' and 'Carrier Config.' interfaces. A dashed red line labeled 'O-FH M-plane Interface' separates the 'Shared O-RU' from the 'O-DU' and 'O-DU (Tenant)'. The diagram also shows 'Untrusted ORAN' and 'Trusted ORAN' regions. + +**Figure A.1-1 Shared O-RU 'All-in-One' Architecture (overview)** + +The following points are considered for the All-in-One architecture: + +- The separation of Host and Tenant refers to the multi-MNO deployment scenario, while a merging of both network functions is referring to the single-MNO deployment. +- The Neutral Host Controller is interfaced via a ‘common M-plane’ to O-RU Netconf Server, and the O-DU (host/tenant) is interfaced via a ‘Carrier Configuration’ to the O-RU Netconf Server. +- The common Netconf client functionality can be embedded either inside O-DU network function or can be placed in an external entity namely neutral host controller (NHC). Anyway, for both deployments the common Netconf client is interfaced to the server via a common M-plane, while the Netconf client is interfaced to the Netconf server for carrier configuration purposes. +- The neutral host controller (NHC) is assumed to be inside an ‘untrusted ORAN’, while the O-RAN specific entities are residing inside the ‘trusted ORAN’. The separation of ‘trusted’ and ‘untrusted’ O-RAN is creating additional threat vectors. + +Figure A.1-2 shows a simplified view of the ‘All-in-One’ architecture. The following points about “host” and “tenant” is considered: + +- The shared O-RU is at the same time interfaces to a host and to a tenant. The term ‘host’ refers to all entities which include host specific functionalities, e.g., Neutral Host Controller or SMO host etc. The term ‘tenant’ refers to all entities which include tenant specific functionalities. +- Both, the host, and the tenant, support a CUS-plane interface, and both support the carrier configuration function via the O-FH M-plane interface. These can be regarded as basic functions of a tenant. +- The host is supporting the common M-plane which is transferred over the O-FH M-plane interface. This is a specific function provided by the host. +- For the shared O-RU the concurrent support of a ‘host’ and ‘tenant’ is required, and therefore needs to be considered for security. + +![Figure A.1-2 Shared O-RU Simplified ‘All-in-One’ Architecture (Security Viewpoint). This diagram illustrates the security architecture for a shared O-RU. It is divided into two main sections: Host (orange) and Tenant (blue). The Host section includes a Neutral Host Controller (opt.) and a Common Netconf Client. The Tenant section includes an SMO (Tenant), a Tenant O-DU, and a Netconf Client. The Shared O-RU at the bottom contains a Netconf Server. Interfaces include O1 Interface (Host to SMO and Tenant to SMO), O1 Interface (Host to Common Netconf Client and Tenant to Netconf Client), CUS-Plane (Host to Netconf Server and Tenant to Netconf Server), and O-FH M-plane Interface (Host to Netconf Server and Tenant to Netconf Server). A Common M-plane is also shown. The architecture is divided into Untrusted ORAN and Trusted ORAN zones.](7adcb0a1ca8872d64af5502faac4e6a2_img.jpg) + +Figure A.1-2 Shared O-RU Simplified ‘All-in-One’ Architecture (Security Viewpoint). This diagram illustrates the security architecture for a shared O-RU. It is divided into two main sections: Host (orange) and Tenant (blue). The Host section includes a Neutral Host Controller (opt.) and a Common Netconf Client. The Tenant section includes an SMO (Tenant), a Tenant O-DU, and a Netconf Client. The Shared O-RU at the bottom contains a Netconf Server. Interfaces include O1 Interface (Host to SMO and Tenant to SMO), O1 Interface (Host to Common Netconf Client and Tenant to Netconf Client), CUS-Plane (Host to Netconf Server and Tenant to Netconf Server), and O-FH M-plane Interface (Host to Netconf Server and Tenant to Netconf Server). A Common M-plane is also shown. The architecture is divided into Untrusted ORAN and Trusted ORAN zones. + +Figure A.1-2 Shared O-RU Simplified ‘All-in-One’ Architecture (Security Viewpoint) + +# Annex change history + +| Date | Revision | Doc status | Author | Description | +|---------------|----------|----------------|--------|-----------------------------------------------------------------------------------------| +| October 2022 | V01.00 | First release | WG11 | Document creation, template | +| March 2023 | V02.00 | Second release | WG11 | Adds assets, threat analysis, and risk analysis | +| July 2023 | V03.00 | Third release | WG11 | Completed security analysis with Issues and Recommendations. | +| November 2023 | V04.00 | Fourth release | WG11 | Adds security analysis for Shared O-RU Resiliency. Adds use of SOH and SRO terminology. | +| March 2024 | V05.00 | Fifth release | WG11 | Add resiliency threats to Risk table. | +| July 2024 | V06.00 | Sixth release | WG11 | Updates Shared O-RU asset-ids | \ No newline at end of file diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/0ae4658097cb4874d7e46bfbe3c3ff4c_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/0ae4658097cb4874d7e46bfbe3c3ff4c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..03bdc4e5555f6299a54d73b2af26c8b587c8be03 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/0ae4658097cb4874d7e46bfbe3c3ff4c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fe82be64a7cf27538b08e3382f977a8ab0adeac0db00e1343e4f3eb006ebe930 +size 39291 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/1c97a7eeecd5f2e5e4eca1c3ca5549e9_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/1c97a7eeecd5f2e5e4eca1c3ca5549e9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..46c18a4dfb203572e4718047ee3c35a78fd5cc81 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/1c97a7eeecd5f2e5e4eca1c3ca5549e9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:63edd88206d876a2a576cc466b85c8e20988dc2b5f1abee9428cdfc8481d227c +size 163518 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/2307f8e9e6758d1d8f66607bfe639b87_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/2307f8e9e6758d1d8f66607bfe639b87_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ed115567a867d5684c677ce90914aa388631619d --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/2307f8e9e6758d1d8f66607bfe639b87_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6d25f3a19eb0a024e9e2ef68cec7f2a97dd43a1cf6feb84592605da06f21b689 +size 4545 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/3bef625e06d93b3036acd87fe0cf6ba7_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/3bef625e06d93b3036acd87fe0cf6ba7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..816695ccc6d612f732bdced88e162e064831df6d --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/3bef625e06d93b3036acd87fe0cf6ba7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f75273600c4d53b2a1bfe4eb46874009faafcec14c6bdfdfbdff919d2ba5bbfe +size 4536 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/3d652e008fe48830e7b24028e93a3903_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/3d652e008fe48830e7b24028e93a3903_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f232fd9ad99b2d468fcafd265f7caea27ed07e70 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/3d652e008fe48830e7b24028e93a3903_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3862ff569ee058469f7a0542e4f992431eab56d58d6da1911991b3c20fca1c82 +size 9492 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/4406a126fbb74f39f19a948bbaab5bd2_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/4406a126fbb74f39f19a948bbaab5bd2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..89e2f2c60407a8c4c680f7be6c891ed37c6fc1a7 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/4406a126fbb74f39f19a948bbaab5bd2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c4c1e5349dd96db921bc7d875565157fc281ba5c46f34914b01ebffefcc752d9 +size 31975 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/44f460ca1dda59f67a004d64f270f832_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/44f460ca1dda59f67a004d64f270f832_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7314b9f83ca629cd68ce322afd6bf86af3c748dc --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/44f460ca1dda59f67a004d64f270f832_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8f6dbbec1f7f39968ec096c68f41a101efd5c35f407715768b01eb7ca7cefb5e +size 38076 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/4856a88565bb10328f26f914a028174e_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/4856a88565bb10328f26f914a028174e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4fec6b94b3b8bad336f70e0d767498af04973301 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/4856a88565bb10328f26f914a028174e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:003e0ad2d72dd1b9fafea509d8a94529915e85fce5039648cf3c126ad51ffed3 +size 4551 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/48778ecb7f3036915bf53cdb6b1c051a_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/48778ecb7f3036915bf53cdb6b1c051a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f089049d33369042bf30d58de6ecdee0e6da697a --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/48778ecb7f3036915bf53cdb6b1c051a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0b902b09f941f4b08ee5909bff6e893b5ba2a7a00ffa1a91e4d5e0e13727b2b7 +size 4497 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/4a50e935a2bc421c1d72417d1cd23ca8_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/4a50e935a2bc421c1d72417d1cd23ca8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cb017690014af5cf82959301f7c62057fb8d8925 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/4a50e935a2bc421c1d72417d1cd23ca8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b7a6ada285d309197b2df8d902cc220f0ff1590ad3e39d19cf43fda98e5e8f81 +size 4490 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/5a8de8bfac61762709b90ee01417b8e7_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/5a8de8bfac61762709b90ee01417b8e7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25cc3520520630d81d22ef15c411a20509a0af25 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/5a8de8bfac61762709b90ee01417b8e7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fb20f4d2d1893a8ceecdc85e0434abf35b53c0a6eb9cebad9f9d0bfed166759e +size 4490 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/6167864b22f75a85ff600225b4a65458_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/6167864b22f75a85ff600225b4a65458_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..29dd6c5a3f498f6973efd6be25bd14791d94422e --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/6167864b22f75a85ff600225b4a65458_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d1a8132c31a129b5dfd522c500f54c7b6199e421cd31a145b9cf81307406609a +size 14765 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/6646e01aa8675caa62aff4c724688b1e_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/6646e01aa8675caa62aff4c724688b1e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4cc3eaba1f268be4eb2c648fc3afc6bc28f3e714 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/6646e01aa8675caa62aff4c724688b1e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8f2d05052613204e953689a584df256bde79814a71dd9c9298f678d25f808359 +size 4519 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/69d3886ee143a62b445dc3e7f016e64c_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/69d3886ee143a62b445dc3e7f016e64c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..337dd7ab699d67c5dea8904634dfa3289d908942 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/69d3886ee143a62b445dc3e7f016e64c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7688f95e9f2d6ecc9062d7c8b5728b05a2ee3c9111d7f38b2639185d08e060d4 +size 23152 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/6d11abffde027642bde4a448a7f4cd38_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/6d11abffde027642bde4a448a7f4cd38_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fdbe18f1a5637af2023e8079d81bcac06cb440ea --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/6d11abffde027642bde4a448a7f4cd38_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e46e5750f56024f5ecd51717ab58135e939531f4d955daeb50c899a6f5a0035f +size 98491 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/70805dbe6f0e6c7423903d383cb47c3d_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/70805dbe6f0e6c7423903d383cb47c3d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..98a03dd7957c548e9e942edb20f7a1f0bb7ee0a8 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/70805dbe6f0e6c7423903d383cb47c3d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d2bd7327f40ced604b4abba509c829e0f730780ac4568eaff2897468bc56a616 +size 27610 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/8119eb3869ff0848506e9a495af2a564_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/8119eb3869ff0848506e9a495af2a564_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bfd0d666a601f0ef06510d8e69969d6c917ab86d --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/8119eb3869ff0848506e9a495af2a564_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6d75246b7dd8aece4943fda8792bda88e9a355ff4c39d99f4abc92f33aefd4cd +size 52950 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/8219af1f6729f3ca610b001b58b1c0df_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/8219af1f6729f3ca610b001b58b1c0df_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ce071a7abf4e69eda1e9d06a6a64a43ae0afb906 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/8219af1f6729f3ca610b001b58b1c0df_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3126628be2ccaa5f96cd657635f0408a536eeec7fcbb7981409b18aab397675a +size 4481 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/845a2970be7ca164d34031810a824e33_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/845a2970be7ca164d34031810a824e33_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1bdb12d7130abdeae4036918c53ee2ff66627525 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/845a2970be7ca164d34031810a824e33_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f0e4abf10807fc04400086d1f9feaf71f7324ff3d6f1ca4dff3538f59efd8893 +size 52164 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/858223875881fb874166b0eaa94a1b10_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/858223875881fb874166b0eaa94a1b10_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..102e239ccd26cd90d481eeb4c8bc14b9698c35e0 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/858223875881fb874166b0eaa94a1b10_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b46b6f66bcbef26dacae952257fea063ac3965f69410c28f31d027586daff65 +size 26012 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/91958aa06a82d00903e46a81fe41189e_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/91958aa06a82d00903e46a81fe41189e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..946f8134125983b500b4848c136f35f0c83ee368 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/91958aa06a82d00903e46a81fe41189e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dbe8a047f5122c274c96c5b405b77a321df7a3d12e2cb639b35d0a3798f28517 +size 4451 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/96af1f9fcaf806ea6a4a9682bff26774_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/96af1f9fcaf806ea6a4a9682bff26774_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1bbebbbe781981ae348227b0667ad2a6c2cfe13 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/96af1f9fcaf806ea6a4a9682bff26774_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1ab3d027f236c4fef05c5a90688346d96ba058952aa94712fa393b6ff70a864c +size 27705 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/99e825c7c0e1382f451d57cf6164fe25_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/99e825c7c0e1382f451d57cf6164fe25_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..507623da1e1c48c7422234eba058c632e2ebc978 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/99e825c7c0e1382f451d57cf6164fe25_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7fdaa7083fccaf9ff4b2273e883f039ef1b3c4faed3583a15dc96e070f344170 +size 71990 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/9ca95b00accdc105096862ce992708d1_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/9ca95b00accdc105096862ce992708d1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ed857f0d7945a461b3cd4c1c05e8f9be002ef2d7 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/9ca95b00accdc105096862ce992708d1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:58895126c8fcce96dfab247a98f4f529aeeec57e8c76f55738b4b36e8414d39d +size 76894 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/a1c2a1a8d109831cdf9592f021e6f51e_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/a1c2a1a8d109831cdf9592f021e6f51e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7d859c343a0cc920a5531ad567d8a10b14405c6c --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/a1c2a1a8d109831cdf9592f021e6f51e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b25d8565108aef8ac2b6886de31956ea23ec7d802ee0c0370bd96a818ba3dfc7 +size 4531 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/a7dd49b6f1024962ff75643188506391_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/a7dd49b6f1024962ff75643188506391_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6bd610d0197e4fbcb6b2ef8fef2f026f71cd1b13 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/a7dd49b6f1024962ff75643188506391_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f2d77926e92e0d04f3fbbb970c255dde8a24915cecb4e2dca93ac15a708c40e3 +size 83317 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/acbb9a7262044b44f476fd78e01a9c9e_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/acbb9a7262044b44f476fd78e01a9c9e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0f8bb1c0861c064939d50d424630957ab60fc31b --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/acbb9a7262044b44f476fd78e01a9c9e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3b74542b5de672102693238ab292d7bb5687c230e7133be7b38ee633e45e3cb1 +size 66681 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/adf6b21d7b50b55cd96cba9767aa698b_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/adf6b21d7b50b55cd96cba9767aa698b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..848c190745f0e461acabf61ae2fcccbe5fbecfb4 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/adf6b21d7b50b55cd96cba9767aa698b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c18897daf782140fb4206ce140a1ab7db593649c1bc147ff1d671bc578502be4 +size 4561 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/af427f0896ca1f2b4963e1bb91640319_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/af427f0896ca1f2b4963e1bb91640319_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8fa7dc70957387cc614afbf4e3f490c19f9a2234 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/af427f0896ca1f2b4963e1bb91640319_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1406e11a7024d72f6733bdb314bbeb74e3b038110a5fa136607418ff2fa12916 +size 36180 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/b0fec44e329d3f54ea81a080f81916fa_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/b0fec44e329d3f54ea81a080f81916fa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bc32e747af2e480b7112c4625d55e092456a8291 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/b0fec44e329d3f54ea81a080f81916fa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2a659a3d3239e5388bfbdfaf5da8d9905633b0e4c56e432e3f867860ff1a0f28 +size 4490 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/b756f94b42598afd4bc2a56ccf7af998_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/b756f94b42598afd4bc2a56ccf7af998_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ac9ca9ad5d40625f350826fa85c332248dcc5f70 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/b756f94b42598afd4bc2a56ccf7af998_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd51137391421651ee36cdf38109ff08cb6602c91d36dc1151bc86a2b802e447 +size 54394 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/b762b1bcda4cd7d5d6e45d8679545f37_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/b762b1bcda4cd7d5d6e45d8679545f37_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ec64b94f9a36fcb73179ccbced32d26c6fba80ec --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/b762b1bcda4cd7d5d6e45d8679545f37_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:63cf68e62f10f68297f363f80b588072ab193aa80aa8dabc39a6bbf2cc8ed5a8 +size 54221 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/bf4612511dbf47fc82af6fb0853a64ff_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/bf4612511dbf47fc82af6fb0853a64ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3979a380ac66e3342150e1c43162d14f82bdedf4 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/bf4612511dbf47fc82af6fb0853a64ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fb61e7678e3b916e1012a575b2f0b9537865b7a7f297bab6b320443f5469cad6 +size 41001 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/c91e19aa227adcdbd86bdbc79e13e6f3_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/c91e19aa227adcdbd86bdbc79e13e6f3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..71ab86613f8bbd1f511c917bb2be79f960fc7bf6 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/c91e19aa227adcdbd86bdbc79e13e6f3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:19b858ff44eb40134dad4afb6fc7119a85aefc60c36f7b26b2beb0366d1c34a6 +size 62173 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/cc23fe6d7eef8191534fe9c252737170_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/cc23fe6d7eef8191534fe9c252737170_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..06a913202837523fac626adbd372fcbd9c1d15c7 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/cc23fe6d7eef8191534fe9c252737170_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:589c9522a17ca54ae3dab05634fe6b090f440c7896114df03d439fd86c5b1207 +size 4495 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/da1448617d22e06e288d94da0df507bc_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/da1448617d22e06e288d94da0df507bc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3f0728e2e5bdccda2cda63af65bc39b61de201a6 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/da1448617d22e06e288d94da0df507bc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7414c35359c6ff36be0b6f6c875185487639340678d3a99da277ebba82e80bb9 +size 68504 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/ee3b71412a542508cf1bf6e2726a8363_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/ee3b71412a542508cf1bf6e2726a8363_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a88479496d8def89a26d4be368f58202a9507b94 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/ee3b71412a542508cf1bf6e2726a8363_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c80926cd4215c5e8b5531f5caa67711b96f7414f7ade146fa1d8965242c0b863 +size 49500 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/f056314e6fbe6c55ff901710bb842a40_img.jpg b/marked/WG2/O-RAN.WG2.AIML-v01.03/f056314e6fbe6c55ff901710bb842a40_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f0389093551049f5cd80fe6c5de30127296d1fc9 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/f056314e6fbe6c55ff901710bb842a40_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8d8d90bc0fecdacdf22f01728f19908446852837477bb97bf3cba3c29b9b6a93 +size 23072 diff --git a/marked/WG2/O-RAN.WG2.AIML-v01.03/raw.md b/marked/WG2/O-RAN.WG2.AIML-v01.03/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..8b9ec657e0e101fe83b7d224bfe048ba7dd67fce --- /dev/null +++ b/marked/WG2/O-RAN.WG2.AIML-v01.03/raw.md @@ -0,0 +1,1337 @@ + + +# **O-RAN Working Group 2 AI/ML workflow description and requirements** --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Working Group 2****AI/ML workflow description and requirements** --- + +Copyright © 2021 by O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189. + +1 + +# Revision History + +| Date | Revision | Author | Description | +|------------|----------|-----------------------------------|--------------------------------------------------------------------------------------------| +| 2020.08.31 | 01.02.00 | R. Jana | Clean Baseline doc | +| 2020.08.31 | 01.02.01 | Intel, ATT, CMCC, Altran, Samsung | Adding approved CR INT.AO-2020.07.06-WG2-CR-0001-AIML model termination procedure-v03.docx | +| 2020.10.09 | 01.02.02 | IBM, ZTE, CMCC | IBM.AO-2020.06.05-WG2-CR-0001-AIML-v05.docx | +| 2020.11.29 | 01.02.03 | Intel, Samsung, Amdocs | INT.AO-2020.10.19-WG2-CR-0006-Reinforcement Learning-v02.docx | +| 2020.11.29 | 01.02.03 | Intel, Samsung, Amdocs | INT.AO-2020.10.19-WG2-CR-0007-DS for RL-v04.docx | +| 2021.01.16 | 01.02.04 | IBM | IBM-2020.06.05-WG2-CR-0002-AIML-v11.docx | +| 2021.01.16 | 01.02.04 | IBM | IBM-2020.06.05-WG2-CR-0003-AIML-v08.docx | +| 2021.01.16 | 01.02.04 | NOK | NOK-2020.11.26-WG2-CR-0001-ModelLifecycle-v03.docx | +| 2021.02.23 | 01.02.04 | ZTE, CMCC | ZTE.AO-2020.06.03-WG2-CR-001-AIML-v8.doc | +| 2021.03.11 | 01.02 | | Editorial updates for publication | +| 2021.05.09 | 01.03.01 | INT | INT.AO-2020.10.19-WG2-CR-0007-DS for RL-v05.docx | +| 2021.05.09 | 01.03.01 | INT | INT-2021.05.05-WG2-CR-00014-DS for RL in Table 2-v01.docx | +| 2021.06.28 | 01.03.02 | INT | INT-2021.06.28-WG2-CR-0019-Federated learning among Non-RT RIC and Near-RT RICs-v02.docx | +| 2021.06.28 | 01.03.02 | QC | QC-2021.06.28-WG2-CR-0001-Correction on control loops v2.docx | +| 2021.06.28 | 01.03.02 | QC | QC-2021.06.28-WG2-CR-0002-Model performance monitoring v2.docx | +| 2021.07.20 | 01.03 | | Editorial updates for publication (final) | + +2 + +# Contents + +| | | +|--------------------------------------------------------------------------|----| +| Revision History ..... | 2 | +| Chapter 1 Introduction..... | 5 | +| 1.1 Scope | 5 | +| 1.2 References..... | 5 | +| 1.3 Definitions and Abbreviations ..... | 6 | +| 1.3.1 Definition ..... | 6 | +| 1.3.2 Abbreviations ..... | 6 | +| Chapter 2 Machine Learning ..... | 8 | +| 2.1 Common terminology and Definitions ..... | 8 | +| 2.2 General principles ..... | 13 | +| 2.3 Types of AI ..... | 14 | +| Chapter 3 Types of Machine Learning algorithms ..... | 15 | +| 3.1 Supervised learning ..... | 15 | +| 3.2 Unsupervised learning ..... | 15 | +| 3.3 Reinforcement learning..... | 16 | +| 3.4 Mapping AI/ML functionalities into O-RAN control loops ..... | 17 | +| 3.5 Federated learning ..... | 18 | +| Chapter 4 Procedure/Interface framework, Data/Evaluation pipelines ..... | 21 | +| 4.1 AI/ML General Lifecycle Procedure and Interface Framework ..... | 21 | +| 4.2 Model Design and Composition ..... | 27 | +| 4.3 Model Runtime Access to Data ..... | 29 | +| 4.4 Data, Model Training and Model Evaluation pipeline..... | 31 | +| 4.5 ML Model Lifecycle Implementation Example..... | 33 | + +| | | | +|----|-----------------------------------------------------------------|----| +| 1 | Chapter 5 Deployment Scenarios ..... | 34 | +| 2 | 5.1 Sequence Diagram for Deployment Scenarios 1.1 and 1.2..... | 37 | +| 3 | 5.2 Criteria for Determining Deployment Scenario (Options)..... | 39 | +| 4 | Chapter 6 Requirements ..... | 42 | +| 5 | 6.1 Functional Requirements ..... | 42 | +| 6 | 6.2 Non-Functional Requirements ..... | 45 | +| 7 | Chapter 7 Key Issues ..... | 46 | +| 8 | 7.1 AI/ML Models in O-RAN Use Cases ..... | 46 | +| 9 | 7.2 AI/ML Model Deployment ..... | 48 | +| 10 | Annex A (Informative) ..... | 50 | +| 11 | A.1 Discussion on A1/O1 clarification ..... | 50 | +| 12 | A.2 Examples of ML model capabilities/descriptors ..... | 50 | +| 13 | Annex N (Informative) ..... | 52 | +| 14 | N.1 Appendix X ..... | 52 | +| 15 | Annex Z: O-RAN Adopter License Agreement ..... | 53 | +| 16 | | | + +# Chapter 1 Introduction + +## 1.1 Scope + +This Technical Report (TR) has been produced by O-RAN Alliance. TRs are informative but they can contain potential functional requirements that will feed into Technical Specifications (TS) eventually. + +The contents of the present document are subject to continuing work within O-RAN WG2 and may change following formal O-RAN approval. In the event that O-RAN Alliance decides to modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +The current document addresses the overall architecture and solution for AI/ML related requirements for the use-cases described in O-RAN WG2 UCR doc [O-RAN-WG2.UCR.02.00.00]. The document provides the terminology, workflow, and requirements, related to AI/ML model training, and its distribution and deployment in the Radio Access Network (RAN). + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 16. + +[1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications" + +[2] 3GPP TS 38.401: "NG-RAN; Architecture description". + +[3] "O-RAN: towards an Open and smart RAN", O-RAN white paper, + +[4] O-RAN WG2 Use Case and Requirements v02.00 + +- [5] O-RAN WG1 O-RAN Architecture Description - v01.00 +- [6] Intelligent Transportation Systems (ITS), ETSI TS 102 637-2 v1.2.1 +- [7] + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definition + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [1]. + +**NMS:** A Network Management System + +**O-DU:** O-RAN Distributed Unit: a logical node hosting RLC/MAC/High-PHY layers based on the 7-2x fronthaul split defined by O-RAN. + +**O-RU:** O-RAN Radio Unit: a logical node hosting Low-PHY layer and RF processing based on the 7-2x fronthaul split defined by O-RAN. + +**Non-RT RIC:** O-RAN non-real-time RAN Intelligent Controller: a logical function that enables non-real-time control and optimization of RAN elements and resources, AI/ML workflow including model training and updates, and policy-based guidance of applications/features in Near-RT RIC. + +**Near-RT RIC:** O-RAN near-real-time RAN Intelligent Controller: a logical function that enables near-real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. + +**O1:** Interface between orchestration & management entities (Orchestration/NMS) and O-RAN managed elements, for operation and management, by which FCAPS management, Software management, File management and other similar functions shall be achieved. + +**A1:** Interface between Non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC applications/functions, and support AI/ML workflow. + +**E2:** Interface between Near-RT RIC and underlying RAN functions (CU-CP, CU-UP, and DU). + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [1]. + +- eNB eNodeB (applies to LTE) +- gNB gNodeB (applies to NR) +- O-DU O-RAN Distributed Unit + +| | | | +|----|-------------|--------------------------------------| +| 1 | O-RU | O-RAN Radio Unit | +| 2 | O-CU | O-RAN Central Unit | +| 3 | RIC | O-RAN RAN Intelligent Controller | +| 4 | Non-RT RIC | Non-real-time RIC | +| 5 | Near-RT RIC | Near-RT RIC | +| 6 | QoE | Quality of Experience | +| 7 | KQI | Key Quality Indicator | +| 8 | KPI | Key performance indicator | +| 9 | CNN | Convolutional neural network | +| 10 | PCA | principal components analysis | +| 11 | RL | reinforcement learning | +| 12 | DRL | deep reinforcement learning | +| 13 | GPU | graphics processing unit | +| 14 | KNN | k nearest neighbors | +| 15 | LSTM | long short-term memory | +| 16 | ML | machine learning | +| 17 | NN | neural network | +| 18 | RL | reinforcement learning | +| 19 | RNN | recurrent neural network | +| 20 | SMO | service management and orchestration | +| 21 | SVM | support vector machine | + +22 + +23 + +# Chapter 2 Machine Learning + +Machine learning is a field of study that provides computers the ability to learn without being explicitly programmed. The ability to learn useful information from input data can help improve RAN or network performance. For example, convolutional neural networks and recurrent neural networks can extract spatial features and sequential features from time-varying signal strength indicators (e.g., RSSI). + +This chapter introduces some of the common terminology related to AI/ML based use-cases development in context of O-RAN architecture. + +## 2.1 Common terminology and Definitions + +**Table 1 - Common terminology** + +| Definitions | Note/example | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Application: An application is a complete and deployable package, environment to achieve a certain function in an operational environment. An AI/ML application is one that contains some AI/ML models. | Generally, an AI/ML application should contain a logically top-level AI/ML model and application-level descriptions | +| ML-assisted Solution: A solution which addresses a specific use case using Machine-Learning algorithms during operation. | As an example, video optimization using ML is an ML-assisted solution. | +| ML Model: The ML methods and concepts used by the ML-assisted solution. Depending on the implementation a specific ML model could have many sub-models as components and the ML model should train all sub-models together. | ML models include supervised learning, unsupervised learning, reinforcement learning, deep neural network, and depending on use-case, appropriate ML model has to be chosen. Separately trained ML models can also be chained together in a ML pipeline during inference. | +| ML Workflow: A ML workflow is the process consisting of data collection and preparation, model building, model training, model deployment, model execution, model validation, continuous model self-monitoring and self-learning/retraining related to ML-assisted solutions | Based on ML model chosen, some or all of the phases of workflow will be included. | + +| | | +|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| ML (model) Life-cycle: The life-cycle of the ML model includes deployment, instantiation and termination of ML model components. | These are operational phases: the initial training, inference, possible re-training | +| ML Pipeline: The set of functionalities, functions, or functional entities specific for an ML-assisted solution. | a ML pipeline may consist of one or several data sources in a data pipeline, a model training pipeline, a model evaluation pipeline and an actor. | +| ML Training Host: The network function which hosts the training of the model, including offline and online training | Non-RT RIC can also be a training host. ML training can be performed offline using data collected from the RIC, O-DU and O-RU. | +| ML Inference Host: The network function which hosts the ML model during inference mode (which includes both the model execution as well as any online learning if applicable). | The ML inference host often coincides with the Actor. The ML-host informs the actor about the output of the ML algorithm, and the Actor takes a decision for an action. | +| Actor: The entity which hosts an ML assisted solution using the output of ML model inference. | | +| Action: An action performed by an actor as a result of the output of an ML assisted solution. | | +| Subject of Action: The entity or function which is configured, controlled, or informed as result of the action. | | +| Model training information: Information needed for training the ML model. | This is the data of the ML model including the input plus optional labels for supervised training | +| Model inference information: Information needed as input for the ML model for inference. | The data needed by an ML model for training and inference may largely overlap, however they are logically different. | +| Model compiling info: Information needed for compiling the ML model. | It includes the trained ML model , model inference host info, and other possible requirements for model compiling, e.g., acceptable accuracy loss thresholds, any specific operations to be performed. | +| Model inference host info: Information of the inference host needed as model compiling info. | This may include information e.g., network bandwidth, memory and computing capabilities of the inference host. | + +| | | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Model Compiling Host: Optional network function which compiles the trained model into specific format for optimized inference execution in an inference host based on the compiling information . |

    Model compiling involves hardware-specific optimization to achieve improved computing and memory efficiency. According to different deployment methods, the compiled model could be published to the model store/ management module as a containerized image (including Inference Engine and compiled models) or a compiled model file format, and then deployed to the inference host.

    Non-RT RIC can also be a compiling host. ML compiling can be performed offline.

    | +| Model Inference Engine: The specific inference framework used to run a compiled model in the inference host. | The functions of model inference engine includes parsing model files, splitting operations, and executing inference instruction stream to finish ML model inference calculation and return inference result. | +| Model Management: The network function that manages the ML models to be deployed in the inference host. | Model management manages models that are onboarded directly from ML training host or those from ML compiling just when model compiling is executed after training. | +| Data Discovery: Data discovery uses smart tools to collect data from multiple sources and then consolidate them to a single source for easy use. | The general process includes data collecting, data cleansing, data loading, data transforming, data mining and data visualization | +| Data Augmentation: Data augmentation could be used to enhance the model generalization and reduce overfitting, especially when dataset is limited or imbalance exists. |

    There are two types of data:

    Time series data: augmentation with consideration of event distribution pattern in temporal space

    Non-time series data: augmentation with physical constraint

    | +| Data Labelling: Data labelling is a time-consuming task and needs domain knowledge. The platform should provide or integrate various labelling/ auto-labelling tools for offline/online annotation. | The labelled data should be validated crossly, and some label mistakes should be eliminated | +| Feature Engineering: At the beginning of model design, we need to study and define what kinds of features could be learnt to | Design the feature extraction mechanism, such as learning from multiple modalities, or learning from single modality, etc. Meanwhile, we need to | + +| | | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +|

    represent the objectives or data, and what kinds of actions should be used to for better prediction performance.

    |

    define which features could be leveraged and which could be fused with other features.

    Nowadays, end2end system building is emerging also, but raw data is also a kind of feature in this context.

    This is an optional operation for model training.

    | +|

    Model Selection: When initiating a training task, ML designer will assess the cost and resources for training or inference, such as hardware platform to inference, GPU memory, inference speed, training accuracy, training time, etc. Based on those requirements analysis, the system can select the corresponding configurations for training or inference.

    |

    For model design, the following factors should be considered:

    • • ML meta architecture for specific tasks
    • • ML/DL framework (pytorch, tensorflow, caffe, etc.)
    • • Data format of input and output
    • • Requirements on model performance (accuracy, responding time, real-time factor, etc.)
    • • Model footprint and HW platform (ARM, GPU, CPU, FPGA, etc.)
    • • Task requirements
    | +|

    Model Optimization: Model optimization refers to the efforts to optimize model performance. Optimizing models based on certain hardware or performance metrics requirements

    |

    For example, using auto machine learning (AutoML) to optimize the hyperparameters or deep learning neural networks (DNN, CNN, RNN, etc.) structure.

    Optimization Metrics:

    • • Model size
    • • Memory used
    • • Inference speed
    • • Accuracy (precision/recall, etc.)

    Hardware platform processing capability, etc.

    According to the hardware platform running models, model compression could also be involved as one of optimization technique.

    | +|

    Model Compression: With specific real-time requirement and hardware constraints, inference engine running on edge device

    |

    At this stage, the system will check the model requirements and running

    | + +| | | +|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| for example, model compression will be critical and a must to further reduce the model footprint and therefore to speed up the inference engine. | hardware platform to decide which compression strategy that could be adopted. The training process will be integrated with compression to generate the satisfied models | +| Model Training: Model training should consider the training platform capability, available resources and energy consumption for training | Meanwhile, the training process should be monitored to see whether the process is converged or collect key information, such as memory used, loss, accuracy, etc. | +| Model Testing: Model testing refers to validate model performance with testing data | It could include the validation process and real testing in product environment. With model testing, we can understand the trained model capability in product environment, and also possible defects. | +| Model Deployment: Model deployment should fully consider the inference hardware capability and stability. | Data input/output should also be considered to reduce I/O delay. | +| Inference Monitoring: Monitoring inference process and collect ML system/model key messages. | | +| Model Refine: After deploying a model for certain time, the model should be refined based on the test results or feedback from the test loop due to the shifting of data distribution, changing of environment, accumulated errors, etc. | | +| Continuous Operations: Provides a series of online functionalities for the continuous improvement of AI/ML models within the whole AI/ML lifecycle. It includes Verification/Monitoring /Analysis /Recommendation /Continue Optimization. | | +| Verification: Verified the model performance online in the real deployed environment | | +| Analysis: Includes data analysis, data/label conflict analysis, performance prediction, business insight etc. | | +| Recommendation : Co-work with analysis to provide continuous improvements recommendations. | | +| Continuous Optimization: Provides AI pipeline optimization, Decision optimization etc. during AI/ML LCM. | | + +![Figure 1: ML components and terminologies diagram. The diagram illustrates the flow of data and model information between various ML components. It starts with 'Data' (UE, O_RU, O_DU, O_CU, CN, AF, OAM, Non-RT RIC, Near-RT RIC) feeding into 'RAW Data'. This data goes to 'Data Preparation' (Data Ingestion/Data Selection, Data Fusion/Data Cleaning), which then feeds into 'Model training info'. This info goes to the 'ML training host' (Model Selection, Feature Engineering (Optional), Model Training & Testing, Model Optimization, Model Refine). The ML training host outputs 'Model Certification/Onboarding' to 'Model Management' (Certification/Onboarding, Deployment/Management/Termination). Model Management outputs 'Model deployment/Termination' to the 'ML inference host' (Feature Engineering (Optional), Model Inference Engine, ML Model inference, ML Model online learning). The ML inference host outputs 'Output' to the 'Actor' (UE O-DU, O-CU, RIC, Non-RT RIC). The Actor outputs 'Action' to the 'Subject of action' (UE O-DU, O-CU, Non-RT RIC, Near-RT RIC). The Subject of action outputs 'Model inference host info' back to the ML inference host. The ML inference host also outputs 'Model inference info' back to the ML training host. The ML training host outputs 'Model compiling info' to the 'ML compiling host (Optional)' (Model compiling (Optional)). The ML compiling host outputs 'Model Certification/Onboarding' back to Model Management. The ML inference host also outputs 'Model performance feedback' back to the 'Data' block. The entire system is supported by 'Continuous Operation' (Verification, Monitoring, Analysis, Recommendation, Continue Optimization).](6d11abffde027642bde4a448a7f4cd38_img.jpg) + +Figure 1: ML components and terminologies diagram. The diagram illustrates the flow of data and model information between various ML components. It starts with 'Data' (UE, O\_RU, O\_DU, O\_CU, CN, AF, OAM, Non-RT RIC, Near-RT RIC) feeding into 'RAW Data'. This data goes to 'Data Preparation' (Data Ingestion/Data Selection, Data Fusion/Data Cleaning), which then feeds into 'Model training info'. This info goes to the 'ML training host' (Model Selection, Feature Engineering (Optional), Model Training & Testing, Model Optimization, Model Refine). The ML training host outputs 'Model Certification/Onboarding' to 'Model Management' (Certification/Onboarding, Deployment/Management/Termination). Model Management outputs 'Model deployment/Termination' to the 'ML inference host' (Feature Engineering (Optional), Model Inference Engine, ML Model inference, ML Model online learning). The ML inference host outputs 'Output' to the 'Actor' (UE O-DU, O-CU, RIC, Non-RT RIC). The Actor outputs 'Action' to the 'Subject of action' (UE O-DU, O-CU, Non-RT RIC, Near-RT RIC). The Subject of action outputs 'Model inference host info' back to the ML inference host. The ML inference host also outputs 'Model inference info' back to the ML training host. The ML training host outputs 'Model compiling info' to the 'ML compiling host (Optional)' (Model compiling (Optional)). The ML compiling host outputs 'Model Certification/Onboarding' back to Model Management. The ML inference host also outputs 'Model performance feedback' back to the 'Data' block. The entire system is supported by 'Continuous Operation' (Verification, Monitoring, Analysis, Recommendation, Continue Optimization). + +Figure 1 depicts the use of the ML components and terminologies as described in Table 1. + +## 2.2 General principles + +Principle 1: In O-RAN we will always have some offline learning as a proposed best practice (even for reinforcement learning type of scenarios). In the current document, offline training means a model is first trained with offline data, and trained model is deployed in the network for inference. Online training refers to scenarios such as reinforcement learning, where the model ‘learns’ as it is executing in the network. However, even in the latter scenario, it is possible that some offline training may happen. + +Principle 2: A model needs to be trained and tested before deploying in the network. A completely untrained model will not be deployed in the network. + +Principle 3: As a best practice, it would be useful if ML Applications are designed in a modular manner that are decoupled from one another. This includes their ability to share data without knowing each other’s data needs. It also implies that they need not understand the location or nature of a data source. For example, an ML Application that is consuming RAN data need not know whether that data is being provided directly via E2, or by some other ML Application on the same Inference Host that is consuming and re-publishing that RAN data. Sections 4.2 and 4.3 describe this in more detail. + +Principle 4: Given that the criteria for determining the deployment scenario for a given ML Application may differ between service providers, as a best practice, it should be possible for a Service Provider to decide whether an ML Application should + +be deployed to a Non-RT RIC or a Near-RT RIC as its Inference Host. See Section 5.2 for a discussion on the types of criteria that may be weighed differently by different providers. + +Principle 5: As a best practice, to improve the execution efficiency and inference performance in the inference host, the ML model for inference should be optimized and compiled with the consideration of the inference host hardware capability. A trade off between efficiency and inference accuracy need to be taken into consideration. Therefore, the optimization should take acceptable accuracy loss as one of the goals, and optimization parameters should be obtained based on this threshold. + +*Note: In Appendix X, an example is provided to show the comparison of the inference performance of the original models and the compiled/optimized model in different inference framework.* + +## 2.3 Types of AI + +Today, AI systems have been able to accomplish certain tasks with a level of accuracy surpassing that of humans. These achievements have been within the scope of narrow AI. However, narrow AI faces challenges and gaps when being applied in real world production environment in scale. For example, most AI systems currently require enormous amounts of data to train machine learning or deep learning models and they have little ability to transfer the knowledge gained through learning from one task to another. To make AI in real-life production environment, we need evolve our AI technologies from narrow AI into advanced, trusted, and scalable AI as shown in Figure 2-1. + +- **Advancing AI:** Powering advances in perception, reasoning, and understanding to help AI address complex human-like tasks. +- **Trusting AI:** Novel techniques to instrument key dimensions of trust and enable AI solutions that inspire confidence. +- **Scaling AI:** Novel technologies across the full computing stack that make AI faster, easier, and able to scale to larger and more complex problems. + +![Diagram illustrating the evolution from narrow AI to advanced, trusted, and scalable AI. It shows three parallel paths: Advancing AI (core algorithms for mastering language, learning and reasoning), Trusting AI (through fairness, robustness, explainability, and transparency), and Scaling AI (by managing, operating & automating its lifecycle). The paths are grouped under 'From narrow to broad AI' and 'Operationalizing AI at scale'.](af427f0896ca1f2b4963e1bb91640319_img.jpg) + +``` + +graph LR + subgraph From_Narrow_to_Broad_AI [From narrow to broad AI] + A1[Advancing AI core algorithms for mastering language, learning and reasoning] + A2[Trusting AI through fairness, robustness, explainability, and transparency] + end + subgraph Operationalizing_AI_at_scale [Operationalizing AI at scale] + A3[Scaling AI by managing, operating & automating its lifecycle] + end + A1 --> B1[Advancing AI] + A2 --> B2[Trusting AI] + A3 --> B3[Scaling AI] + +``` + +Diagram illustrating the evolution from narrow AI to advanced, trusted, and scalable AI. It shows three parallel paths: Advancing AI (core algorithms for mastering language, learning and reasoning), Trusting AI (through fairness, robustness, explainability, and transparency), and Scaling AI (by managing, operating & automating its lifecycle). The paths are grouped under 'From narrow to broad AI' and 'Operationalizing AI at scale'. + +**Figure 2-1 - From Narrow AI to Advanced, Trusted, and Scalable AI** + +Copyright © 2021 by the O-RAN Alliance e.V. Your use is subject to the terms of the O-RAN Adopter License Agreement in the Annex Z. + +# Chapter 3 Types of Machine Learning algorithms + +This section provides a view of how the different ML algorithms can be deployed and realized in O-RAN architecture. It does not detail or recommend the various machine learning algorithms available or recommend specific ML algorithms that should be applied to the use-cases realized in O-RAN architecture. + +## 3.1 Supervised learning + +Input data is called training data and has a known label or result. Supervised learning is a machine learning task that aims to learn a mapping function from the input to the output, given a labeled data set. + +1. Regression: Linear Regression, Logistic Regression +2. Instance-based Algorithms: k-Nearest Neighbor (KNN) +3. Decision Tree Algorithms: CART +4. Support Vector Machines: SVM +5. Bayesian Algorithms: Naive Bayes +6. Ensemble Algorithms: Extreme Gradient Boosting, Bagging: Random Forest + +Supervised learning can be further grouped into Regression and Classification problems. Classification is about predicting a label whereas Regression is about predicting a quantity. + +![Figure 3-1: Supervised learning model training and actor locations. The diagram shows two architectural options separated by 'or'. Option 1: A large orange box labeled 'Non-RT-RIC' contains two smaller grey boxes: 'ML Training host' and 'ML Model host / Actor', connected by a right-pointing arrow. Below this box is another orange box labeled 'Near-RT-RIC'. A vertical blue line labeled 'A1' connects the 'ML Training host' box to the 'Near-RT-RIC' box. Option 2: A large orange box labeled 'Non-RT-RIC' contains a single grey box 'ML Training host'. Below this box is another orange box labeled 'Near-RT-RIC' which contains a grey box 'ML Model host / Actor'. A vertical blue line labeled 'A1' connects the 'ML Training host' box to the 'ML Model host / Actor' box.](f056314e6fbe6c55ff901710bb842a40_img.jpg) + +Figure 3-1: Supervised learning model training and actor locations. The diagram shows two architectural options separated by 'or'. Option 1: A large orange box labeled 'Non-RT-RIC' contains two smaller grey boxes: 'ML Training host' and 'ML Model host / Actor', connected by a right-pointing arrow. Below this box is another orange box labeled 'Near-RT-RIC'. A vertical blue line labeled 'A1' connects the 'ML Training host' box to the 'Near-RT-RIC' box. Option 2: A large orange box labeled 'Non-RT-RIC' contains a single grey box 'ML Training host'. Below this box is another orange box labeled 'Near-RT-RIC' which contains a grey box 'ML Model host / Actor'. A vertical blue line labeled 'A1' connects the 'ML Training host' box to the 'ML Model host / Actor' box. + +**Figure 3-1 Supervised learning model training and actor locations** + +In supervised learning (see Figure 3-1), Non-RT RIC is part of the SMO and thus is part of the management layer. ML training host and ML model host/actor can be part of Non-RT RIC or Near-RT RIC. + +## 3.2 Unsupervised learning + +Input data is not labeled and does not have a known result. Unsupervised learning is a machine learning task that aims to learn a function to describe a hidden structure from unlabeled data. Some examples of unsupervised learning are K-means clustering and principal component analysis (PCA). + +![Figure 3-2: Unsupervised learning model training and actor locations. The diagram shows two configurations separated by 'or'. In the first configuration, a 'Non-RT-RIC' block contains an 'ML Training host' and an 'ML Model host / Actor', with an arrow pointing from the training host to the model host/actor. A vertical line labeled 'A1' connects this block to a 'Near-RT-RIC' block below it. In the second configuration, the 'Non-RT-RIC' block contains only the 'ML Training host', and the 'Near-RT-RIC' block contains the 'ML Model host / Actor'. A vertical line labeled 'A1' connects the training host in the Non-RT-RIC block to the model host/actor in the Near-RT-RIC block.](858223875881fb874166b0eaa94a1b10_img.jpg) + +Figure 3-2: Unsupervised learning model training and actor locations. The diagram shows two configurations separated by 'or'. In the first configuration, a 'Non-RT-RIC' block contains an 'ML Training host' and an 'ML Model host / Actor', with an arrow pointing from the training host to the model host/actor. A vertical line labeled 'A1' connects this block to a 'Near-RT-RIC' block below it. In the second configuration, the 'Non-RT-RIC' block contains only the 'ML Training host', and the 'Near-RT-RIC' block contains the 'ML Model host / Actor'. A vertical line labeled 'A1' connects the training host in the Non-RT-RIC block to the model host/actor in the Near-RT-RIC block. + +**Figure 3-2 - Unsupervised learning model training and actor locations** + +In unsupervised learning (see Figure 3-2), ML training host and ML model host/actor can be part of Non-RT RIC or Near-RT RIC. + +## 3.3 Reinforcement learning + +A goal-oriented learning based on interaction with environment. In reinforcement learning (RL), the agent aims to optimize a long-term objective by interacting with the environment based on a trial and error process. The most typical RL framework is based on Markov Decision Process (MDP), which is defined by a 4-tuple $(S, A, R, T)$ , where: + +- $S$ is the state space of an environment +- $A$ is the set of actions an agent can select from +- $R$ is the reward function +- $T$ is the transition probability function + +There are multiple ways to categorize RL algorithms, and one widely used classification is: model-based RL vs. model-free RL. In wireless network, it might be beneficial to rely on a model for predicting future behavior of the environment. In model-based RL algorithms, reward and transition probability is based on a predictive model of the environment. The agent uses the model to find out what will happen if an action is taken. On the other hand, the model of the environment might not be of interest or hard to obtain for some use cases. Model-free algorithms forgo any explicit knowledge of the dynamics of the environment and evaluate how good actions are through exploration and exploitation. RL algorithms can also be categorized into value-based RL vs. policy-based RL, on-policy RL vs. off-policy RL, etc. There are several RL algorithms + +- Q-learning +- Multi-armed bandit learning +- Deep Q Network +- State-Action-Reward-State-Action (SARSA) +- Temporal Difference learning +- Actor-critic reinforcement learning +- Deep deterministic policy gradient +- Trust region policy optimization +- Dyna-Q +- Monte-Carlo tree search + +![Figure 3-3: Reinforcement learning model training and actor locations. The diagram shows three scenarios (a, b, c) for the placement of ML training and model components across Non-RT-RIC and Near-RT-RIC layers, connected by O1/A1 interfaces.](96af1f9fcaf806ea6a4a9682bff26774_img.jpg) + +The diagram illustrates three architectural options for reinforcement learning (RL) components across two layers: Non-RT-RIC (top) and Near-RT-RIC (bottom). The components are connected via O1/A1 interfaces. + +- (a) Reinforcement learning:** Both the ML Training host and the ML Model host / Actor are co-located within the Non-RT-RIC layer. +- (b) Online RL:** Both the ML Training host and the ML Model host / Actor are co-located within the Near-RT-RIC layer. +- (c) Offline RL:** The ML Training host is located in the Non-RT-RIC layer, while the ML Model host / Actor is located in the Near-RT-RIC layer. + +Figure 3-3: Reinforcement learning model training and actor locations. The diagram shows three scenarios (a, b, c) for the placement of ML training and model components across Non-RT-RIC and Near-RT-RIC layers, connected by O1/A1 interfaces. + +**Figure 3-3- Reinforcement learning model training and actor locations** + +For reinforcement learning (see Figure 3-3a), ML training host and ML model host/actor shall be co-located as part of Non-RT RIC. For online RL in the Near-RT RIC (see Figure 3-3b), ML training host and ML model host/actor shall be co-located as part of Near-RT RIC. For offline RL (see Figure 3-3c), ML training host is located as part of Non-RT RIC, and ML model host/actor is located as part of Near-RT RIC. The offline trained model is updated based on the performance monitoring of the interaction between the ML model host/actor (RL agent) and the RAN environment. + +## 3.4 Mapping AI/ML functionalities into O-RAN control loops + +There are three types of control loops defined in O-RAN. ML assisted solutions fall into the three control loops. Time scale of O-RAN control loops depend on what is being controlled, e.g., system parameters, resources or radio resource management (RRM) algorithm parameters. For example, if O-RAN control loop adapts the parameters of RRM algorithms, its time scale is slower than that of the RRM algorithm which directly controls resource. + +Loop 1 deals with per TTI msec level scheduling and operates at a time scale of the TTI or above. Loop 2 operates in the near RT RIC operating within the range of 10-1000 msec. Loop 3 operates in the Non-RT RIC at greater than 1000 msec (policies, orchestration). It is not expected that these loops are hierarchical but can instead run in parallel. + +![Figure 3-4 - Control loops in O-RAN. The diagram illustrates the O-RAN architecture and its control loops. At the top is the 'Service Management and Orchestration Framework' containing the 'Non-Real Time RIC'. Below it is the 'Near-Real Time RIC'. The architecture includes 'O-eNB', 'O-CU-CP', 'O-CU-UP', 'O-DU', 'O-RU', and 'O-Cloud'. The 'Open Fronthaul M-Plane' and 'Open Fronthaul CUS-Plane' are shown. The 'Legend' defines the control loops: Non-real-time Control Loops (green circle), Near-real-time Control Loops (yellow circle), and Real-time Control Loops (red circle). The 'Typical Ranges' for control loops are: Non-RT control loops (>= ~1s), Near-RT control loops (> ~10ms < ~1s), and Real-time Control Loops (< ~10ms). The diagram shows various interfaces: O1, O2, A1, E1, E2, F1-c, F1-u, X2-c, X2-u, NG-u, Xn-c, and NG-c. The 'O-Cloud' is connected to the 'O-DU' and 'O-RU'.](a7dd49b6f1024962ff75643188506391_img.jpg) + +Figure 3-4 - Control loops in O-RAN. The diagram illustrates the O-RAN architecture and its control loops. At the top is the 'Service Management and Orchestration Framework' containing the 'Non-Real Time RIC'. Below it is the 'Near-Real Time RIC'. The architecture includes 'O-eNB', 'O-CU-CP', 'O-CU-UP', 'O-DU', 'O-RU', and 'O-Cloud'. The 'Open Fronthaul M-Plane' and 'Open Fronthaul CUS-Plane' are shown. The 'Legend' defines the control loops: Non-real-time Control Loops (green circle), Near-real-time Control Loops (yellow circle), and Real-time Control Loops (red circle). The 'Typical Ranges' for control loops are: Non-RT control loops (>= ~1s), Near-RT control loops (> ~10ms < ~1s), and Real-time Control Loops (< ~10ms). The diagram shows various interfaces: O1, O2, A1, E1, E2, F1-c, F1-u, X2-c, X2-u, NG-u, Xn-c, and NG-c. The 'O-Cloud' is connected to the 'O-DU' and 'O-RU'. + +**Figure 3-4 - Control loops in O-RAN** + +Figure 3-4 shows the three control loops in O-RAN architecture. AI/ML related functionalities can be mapped into the three loops. The location of the ML model training and the ML model inference for a use case depends on the computation complexity, on the availability and the quantity of data to be exchanged, on the response time requirements and on the type of ML model. For example, online ML model for configuring RRM algorithms operating at the TTI time scale could run in O-DU, while the configuration of system parameters such as beamforming configurations requiring a large amount of data with no response time constraints can be performed using the combination of Non-RT RIC and SMO where intensive computation means can be made available. + +In the first phase of O-RAN, ML model training will be considered mainly in the Non-RT RIC and ML model inference will be considered in loops 2 and 3. For loop2, the ML inference is typically running in Near-RT RIC. For Loop 1, the ML model inference is typically running in an O-DU. ML workflow on loop 1 is not covered by this version of the technical report. While ML model implementation in O-RU could be envisaged, it is presently not supported in O-RAN. + +## 3.5 Federated learning + +Federated learning is a well-known distributed learning methodology where multiple AI/ML entities collaboratively train an AI/ML model. Instead of gathering training data into a central server, federated learning keeps the training data decentralized to mitigate privacy risks. AI/ML models are trained locally in distributed entities, and the local models are aggregated by a central server. The central server orchestrates the federated learning. + +In O-RAN architecture, since both Non-RT RIC and Near-RT RIC are capable of AI/ML training, the Non-RT RIC can serve as the central server in the federated learning, and its connected Near-RT RICs can serve as distributed AI/ML entities as illustrated in Figure 3-5. + +Note: Other federated learning deployment scenarios are FFS. + +![Figure 3-5: Federated learning model training and actor locations. The diagram shows a Non-RT RIC (orange box) containing an ML Training host. This host is connected via an O1/A1 interface to a Near-RT RIC (orange box). The Near-RT RIC contains an ML Training host and an ML model host / Actor. An arrow points from the ML Training host to the ML model host / Actor within the Near-RT RIC.](6167864b22f75a85ff600225b4a65458_img.jpg) + +Figure 3-5: Federated learning model training and actor locations. The diagram shows a Non-RT RIC (orange box) containing an ML Training host. This host is connected via an O1/A1 interface to a Near-RT RIC (orange box). The Near-RT RIC contains an ML Training host and an ML model host / Actor. An arrow points from the ML Training host to the ML model host / Actor within the Near-RT RIC. + +**Figure 3-5: Federated learning model training and actor locations** + +![Figure 3-6: Procedure of federated learning among Non-RT RIC and Near-RT RICs. The diagram illustrates a loop for federated learning. A Non-RT RIC (yellow box) contains a Model training host. A Near-RT RIC (pink box) contains a Model training host and a Model inference host. The process starts with '1. Model distributed to Near-RT RICs' from the Non-RT RIC to the Near-RT RIC. A loop labeled '[until convergence]' contains steps: '2. Local training' in the Near-RT RIC, '3. Upload local model' from the Near-RT RIC to the Non-RT RIC, '4. Update model' in the Non-RT RIC, and '5. Model download' from the Non-RT RIC to the Near-RT RIC. After the loop, '6. Model deployed for inference' occurs in the Near-RT RIC.](bf4612511dbf47fc82af6fb0853a64ff_img.jpg) + +Figure 3-6: Procedure of federated learning among Non-RT RIC and Near-RT RICs. The diagram illustrates a loop for federated learning. A Non-RT RIC (yellow box) contains a Model training host. A Near-RT RIC (pink box) contains a Model training host and a Model inference host. The process starts with '1. Model distributed to Near-RT RICs' from the Non-RT RIC to the Near-RT RIC. A loop labeled '[until convergence]' contains steps: '2. Local training' in the Near-RT RIC, '3. Upload local model' from the Near-RT RIC to the Non-RT RIC, '4. Update model' in the Non-RT RIC, and '5. Model download' from the Non-RT RIC to the Near-RT RIC. After the loop, '6. Model deployed for inference' occurs in the Near-RT RIC. + +**Figure 3-6: Procedure of federated learning among Non-RT RIC and Near-RT RICs** + +The procedure of federated learning among Non-RT RIC and Near-RT RICs can be summarized into following steps: + +- Step 1: The Non-RT RIC distributes the AI/ML model to its connected Near-RT RICs. +- Step 2: The ML training host in the Near-RT RIC trains local model using training data collected locally. Note that training data collected locally are not required to be transferred to the Non-RT RIC. +- Step 3: Local model weights or gradients are uploaded to the Non-RT RIC. +- Step 4: The training host in the Non-RT RIC update the AI/ML model (e.g., using FedSGD, FedAvg, etc.). +- Step 5: The updated model is downloaded to the Near-RT RICs. +- Step 6: If the model training converges, then the model is deployed for inference in the Near-RT RIC. + +A1-ML (model management) service can be used to manage model downloading/distribution and uploading/aggregation in federated learning. For example, + +- The Non-RT RIC can subscribe/request model uploading from its connected Near-RT RICs. +- The Non-RT RIC can notify its connected Near-RT RIC to download a model. + +- 1 ML model download and upload between Non-RT RIC and Near-RT RICs over O1 or A1 interface is FFS. +- 2 + +Image: O-RAN Alliance Logo + +O-RAN.WG2.AIML-v01.03 + +# Chapter 4 Procedure/Interface framework, Data/Evaluation pipelines + +## 4.1 AI/ML General Lifecycle Procedure and Interface Framework + +This chapter first provides the general framework of AI/ML procedure and interfaces, which addresses the ML components rather than network functions (Non/Near-RT RIC, etc.). The potential mapping relationship between the ML components and network functions, interfaces defined in O-RAN are also illustrated in Figure 4-1. + +![Figure 4-1 - AI/ML General Procedure](9ca95b00accdc105096862ce992708d1_img.jpg) + +*Detailed Diagram Description:* The diagram shows the workflow of the AI/ML General Procedure. It starts with 'Data Collection' (which receives data from O-CU/O-DU, Near-RT RIC, Non-RT RIC, Data collector via O1/A1/E2 interfaces). The data goes to 'Data Preparation', which outputs 'AI/ML Training data' to 'AI/ML Training' and 'AI/ML Inference Data' to 'AI/ML Inference'. 'AI/ML Training' outputs to 'AI/ML Model Management' (Model Certification/On-boarding), which in turn deploys/terminates models to 'AI/ML Inference' and provides guide/feedback to 'AI/ML Continuous Operation'. 'AI/ML Inference' interacts with 'AI/ML Continuous Operation' via verification/monitoring and ML performance feedback. 'AI/ML Continuous Operation' receives data from O-CU/O-DU, Near-RT RIC, Non-RT RIC, Data collector via O1/A1/E2. 'AI/ML Inference' outputs to 'AI/ML Assisted Solution', which triggers 'Action' through three paths: 'Config mang. over O1' (Subject of actions: near-RT RIC, O-CU, O-DU/O-RU), 'Control Action/Guidance over E2' (Subject of actions: O-CU, O-DU/O-RU), and 'Policy over A1, E2' (Subject of actions: near-RT RIC, O-CU, O-DU/O-RU). ML performance feedback is sent back from these actions to 'AI/ML Continuous Operation'. + +Figure 4-1 - AI/ML General Procedure + +**Figure 4-1 - AI/ML General Procedure** + +***Note:** ML capabilities shall be stored in the management system (FFS). Query and Discovery of ML capabilities are terminated in the management system but not shown. ML inference host often coincides with the actor* + +***Note:** "AI/ML Training" in the Figure 4-1 indicates "Training" only. (currently does not include re-training)* + +As Model Management/Data Preparation/AI/ML Training are implementation variability components, there are many combinations of the deployment scenarios. The typical deployment scenarios that are considered for AI/ML architecture/framework in O-RAN architecture are: + +- Deployment Scenario 1.1: AI/ML Continuous Operation/AI/ML Model Management/Data Preparation/ AI/ML Training and AI/ML Inference are all in Non-RT RIC + +Copyright © 2021 by the O-RAN Alliance e.V. Your use is subject to the terms of the O-RAN Adopter License Agreement in the Annex Z. + +21 + +2. Deployment Scenario 1.2: AI/ML Continuous Operation/Data Preparation (for training)/AI/ML Training are in Non-RT RIC, AI/ML Model Management is out of Non-RT RIC (in or out of SMO). Data Collection (for inference)/Data Preparation (for inference)/AI/ML Inference is in Near-RT RIC +3. Deployment Scenario 1.3: AI/ML Continuous Operation/AI/ML Inference are in Non-RT RIC. Data Preparation/AI/ML Training / AI/ML Model Management are out of Non-RT RIC (in or out of SMO). +4. Deployment Scenario 1.4: Non-RT RIC acts as the ML training host for offline model training and the Near-RT RIC as the ML training host for online learning and ML inference host. +5. Deployment Scenario 1.5: Continuous Operation/Model management/Data Preparation/ML Training host are in Non-RT RIC. O-CU/O-DU act as the ML inference host (for FFS). + +*Note: Deployment of "AI/ML Continuous Operation" outside of non-RT RIC is in study and FFS* + +エラー! 参照元が見つかりません。 shows the various deployment scenarios and interfaces. + +**Table 2 - AI/ML deployment scenarios** + +| Deployment Scenario | Data Preparation | AI/ML Training | AI/ML Inference | Model Management | Continuous Operation | Subject of Action | Action from inference host to subject | | Enrichment data for inference | +|---------------------|----------------------------|-------------------|-----------------|-------------------|----------------------|-------------------|---------------------------------------|----------------------|-------------------------------| +| | | | | | | | Config Mgmt. (CM) | Policy Control | | +| Scenario 1.1 | Non-RT RIC | Non-RT RIC | Non-RT RIC | Non-RT RIC | Non-RT RIC | Near-RT RIC | O1 | A1 (policy) | SMO internal | +| | | | | | | O-CU, O-DU, O-RU | O1 | N/A | SMO internal | +| Scenario 1.2 | Non-RT RIC and Near-RT RIC | Non-RT RIC | Near-RT RIC | Out of Non-RT RIC | Non-RT RIC | Near-RT RIC | near-RT RIC internal | near-RT RIC internal | A1 | +| | | | | | | O-CU, O-DU, O-RU | N/A | E2 (control/policy) | E2 (if applicable) | +| Scenario 1.3 | Out of Non-RT RIC | Out of Non-RT RIC | Non-RT RIC | Out of Non-RT RIC | Non-RT RIC | Near-RT RIC | near-RT RIC internal | near-RT RIC internal | A1 | +| | | | | | | O-CU, O-DU, O-RU | FFS | FFS | FFS | + +| | | | | | | | | | | +|--------------------|----------------------------|----------------------------------------------------------------------------|-------------|----------------------------|-------------|------------------|----------------------|----------------------|-----| +| Scenario 1.4 | Non-RT RIC and Near-RT RIC | SMO/Non-RT RIC for offline training

    Near-RT RIC for online learning | Near-RT RIC | Non-RT RIC and Near-RT RIC | Near-RT RIC | Near-RT RIC | Near-RT RIC internal | Near-RT RIC internal | A1 | +| | | | | | | O-CU, O-DU, O-RU | N/A | | | +| Scenario 1.5 (FFS) | Non-RT RIC | Non-RT RIC | O-CU / O-DU | Non-RT RIC | Non-RT RIC | O-CU, O-DU, O-RU | FFS | FFS | FFS | + +Note: Configuration management for scenario 1.2 and 1.4 via E2 are FFS; Non-RT RIC can use SMO internal interfaces to trigger configuration changes over O1 + +Note 2: ML model transfer between Non-RT RIC and Near-RT RIC over A1 interface is FFS. + +Based on the framework, some key phases of machine learning are expected to be applied to any ML-assisted solution planned in O-RAN architecture. Any use case defined for ML-assisted solution shall have one or more phases (as applicable) and the phases are defined below: + +### 1. ML model and inference host capability query/discovery + +This procedure shall be executed whenever AI/ML model is to be used for ML-assisted solution. This procedure can be executed at start-up or run-time (when a new ML model is to be executed or existing ML model is to be updated). The SMO/Non-RT RIC will discover various capabilities and properties of the ML inference host, and the ML-assisted solution such as: + +- Processing capability of the inference host (for example: dedicated resources such as CPU/GPU, memory etc. for ML model inference). +- Requirements on the ML assisted solutions such as execution time cap, delay sensitivity +- Properties such as supported ML model formats and ML engines (for example: Protobuf, JSON, or any ONAP specific VES data formats). +- NFVI based architecture support in MF to run ML model(s) +- Data-sources available to run ML-pipeline (for example: support for data streams, data lake, or any specific database access) + +This discovery of the capabilities and properties shall be used to check: + +- if an ML model can be executed in the target ML inference host (MF), + +b) which ML models can be executed in the MF. + +*Note: Exact mechanism and contents of capabilities discovery is FFS.* + +### 2. ML model Training and Generation + +This procedure corresponds to design time selection and training of a ML model in relation with a specific ML-assisted solution (use case) to be executed. The ML designer or the SMO/Non-RT RIC will select and onboard the ML model and relevant meta data into the ML training host. Utilizing on the ML training data collection, the ML training host will initiate the model training. Once the model is trained and validated, it is published back in the SMO/Non-RT RIC catalogue. In addition, new trained ML models for a given ML-assisted solution can be generated also by modification techniques such as compression, truncation etc., or training on different training data sets. These ML models are also published in the SMO/Non-RT RIC catalogue. + +### 3. ML model Selection + +The ML designer can check whether a trained ML model from the SMO/Non-RT RIC catalogue can be deployed in the ML inference host for the given ML-assisted solution, by mapping the ML model and ML assisted solution requirements to performance capabilities discovered from Step 1. Upon successful validation, ML designer will inform the SMO/Non-RT RIC to initiate model deployment. + +### 4. ML model Deployment and Inference + +The AI/ML model that is selected for the ML use case can be deployed via containerized image to MF where ML model shall be running. The container image also includes the necessary configuration of ML inference host with the AI/ML model description file. + +*Note: The O1 interface mechanism for ML model deployment is being specified by WG1.* + +Once the ML model is deployed and activated, ML online data shall be used for inference in ML-assisted solutions, which includes: + +- a) 3GPP specific events/counters (across all different Managed Elements) over O1/E2 interface + - a. Events: 3GPP 32.423 + - b. Counters: 3GPP 32.425 +- b) Non-3GPP specific events/counters (across all different Managed Elements) over O1/E2 interface (to be defined in O-RAN WGs) +- c) Enrichment information from Non-RT RIC over A1 interface (to be defined in O-RAN WGs) + +Based on the output of the ML model, the ML-assisted solution will inform the Actor to take the necessary actions towards the Subject. These could include CM changes over O1 interface, policy management over A1 interface, or control actions or policies over E2 interface, depending on the location of ML inference host and Actor. + +### 5. ML model performance monitoring + +The ML inference host and actors are expected to feedback or report the performance of the ML model to the SMO/Non-RT RIC so that the SMO/Non-RT RIC can monitor the performance (e.g., accuracy, running time, network KPIs) of the ML + +model and potentially update the model or reselect the model to be executed. Based on the use-case, specific set of data as applicable for use-case shall be used for ML model re-training. Based on the performance evaluation, either some guidance can be provided to use a different model in the ML inference host, or a notification can be sent indicating the need for retraining the model. + +*Note: Feedback mechanism and how the ML model switching can occur at runtime is FFS.* + +### 6. ML model retraining update + +Based on the feedback and data received from various MFs and actors, the SMO/Non-RT RIC can inform the ML designer that an update is required to the current model. The ML designer will initiate the model selection and training step, but with the existing trained model. Once the model has been retrained, it will be deployed as described in Step 3, and the updated model will be used for ML inference. + +### 7. ML model reselection + +Based on the feedback and data received from various MFs and actors, the SMO/Non-RT RIC can inform the ML designer or the the respective module that the running ML model does not comply with the requirements (e.g., because the HW capabilities of the ML inference host or the execution time/delay constraints have changed) and thus a different ML model is necessary to drive the ML application. The SMO/Non-RT RIC or the ML designer selects a suitable ML model from the ML model catalogue and deploys it in the ML inference host as in Step 4. + +### 8. ML model termination + +In certain scenarios involving severe degradation in the ML model performance, a simple model update and redeployment may not be the suitable option. To avoid large impact on network, malfunctioning ML models (or models that are degrading) need to be terminated. Non-RT RIC needs to have access to ML model's termination conditions to determine whether a ML model is working properly or not. Termination conditions are regarded as ML model attributes. + +For example, if a ML model is used to predict QoE, then one termination condition for this ML model could be "when the prediction accuracy is below a certain threshold". Typically, the statistical properties of a target variable, which the model is trying to predict, changes over time (i.e., drift) in unforeseen ways. This causes problems because the prediction become less accurate as time passes. In another example, if a ML model is used to optimize handover sequences, then one possible termination condition could be "when the generated neighbor relation table leads to an increase in number of handover ping pongs or handover failures above a certain threshold". Network KPI monitoring can be used as general termination conditions for an AI/ML model to detect anomaly, i.e., when the performance of a model does not meet its baseline. + +For AI/ML-assisted solutions, there are at least following scenarios: + +1. A single ML model (for one application/use case) impacts the monitored network KPIs +2. Multiple ML models are chained together in one application/use case, and these models collectively contribute to the monitored network KPIs +3. Multiple ML models for different applications/use cases contribute to the monitored network KPIs + +Mechanism to identify malfunctioning ML model varies for the above scenarios. For scenario 1, network KPI degradation would serve as a good indicator for ML model performance degradation. However, for scenario 2 and 3, it might be hard to pin-point the degraded model(s) only based on the network KPI monitoring. Different approaches can be used to address scenario 2 and 3. For example, Non-RT RIC could first identify candidate models that may be causing the network KPI + +degradation, and then Non-RT RIC could terminate these suspect models one by one until the RAN performance gets back to normal. Another approach could be that Non-RT RIC decides to terminate all relevant AI/ML models at the same time. + +![Figure 4-2: ML model termination based on performance monitoring at Non-RT RIC. The diagram shows a sequence of interactions between the Service Management and Orchestration (SMO) and the O-RAN components. The SMO includes a 'Collection & Control' block and a 'non-RT RIC' block. The O-RAN includes a 'near-RT RIC' block and 'E2 Nodes'. The process starts with 'Termination conditions' being sent from the non-RT RIC to the Collection & Control. This triggers a 'Performance monitoring' block. Data Collection (PM data and FM data) is sent from the near-RT RIC to the Performance monitoring block. The Performance monitoring block then sends 'PM data and FM data' to the non-RT RIC. The non-RT RIC checks if 'Termination conditions met' and, if true, starts the 'ML model termination procedure'.](ee3b71412a542508cf1bf6e2726a8363_img.jpg) + +Figure 4-2: ML model termination based on performance monitoring at Non-RT RIC. The diagram shows a sequence of interactions between the Service Management and Orchestration (SMO) and the O-RAN components. The SMO includes a 'Collection & Control' block and a 'non-RT RIC' block. The O-RAN includes a 'near-RT RIC' block and 'E2 Nodes'. The process starts with 'Termination conditions' being sent from the non-RT RIC to the Collection & Control. This triggers a 'Performance monitoring' block. Data Collection (PM data and FM data) is sent from the near-RT RIC to the Performance monitoring block. The Performance monitoring block then sends 'PM data and FM data' to the non-RT RIC. The non-RT RIC checks if 'Termination conditions met' and, if true, starts the 'ML model termination procedure'. + +**Figure 4-2. ML model termination based on performance monitoring at Non-RT RIC** + +As illustrated in Figure 4-2, AI/ML model performance monitoring is assumed to be placed in the Non-RT RIC. Based on the model performance monitoring, the Non-RT RIC can calculate performance metrics and compare them against termination conditions of a model. If the termination conditions are met, the model termination procedure should be triggered. + +In the ML model termination procedure, ML inference host, which can be in Non-RT RIC or Near-RT RIC based on deployment scenarios, would receive termination commands requesting to stop the ML inference. A backup solution, which can be another well trained and tested ML model, a slightly modified version of the given ML model (e.g., compressed or less compressed versions, truncated or less truncated versions etc.), or, more conservatively, a non-AI-based algorithm, needs to be provided to ML inference host. After terminating the model and activating the backup solution, the ML inference host should send out messages to acknowledge the commands. The above discussion is summarized in Figure 4-3. + +![Figure 4-3: ML model termination procedure. The diagram shows a sequence of interactions between the SMO/Non-RT RIC and the ML Inference Host. The SMO/Non-RT RIC sends a 'Termination command (model identification)' to the ML Inference Host. The ML Inference Host then 'Terminate the corresponding ML model'. The ML Inference Host sends an 'Acknowledgement to successful termination' back to the SMO/Non-RT RIC. The SMO/Non-RT RIC then sends a 'Backup solution activation command (Backup solution description)' to the ML Inference Host. The ML Inference Host then 'Active backup solution'. Finally, the ML Inference Host sends an 'Acknowledgement to successful activation' back to the SMO/Non-RT RIC.](44f460ca1dda59f67a004d64f270f832_img.jpg) + +Figure 4-3: ML model termination procedure. The diagram shows a sequence of interactions between the SMO/Non-RT RIC and the ML Inference Host. The SMO/Non-RT RIC sends a 'Termination command (model identification)' to the ML Inference Host. The ML Inference Host then 'Terminate the corresponding ML model'. The ML Inference Host sends an 'Acknowledgement to successful termination' back to the SMO/Non-RT RIC. The SMO/Non-RT RIC then sends a 'Backup solution activation command (Backup solution description)' to the ML Inference Host. The ML Inference Host then 'Active backup solution'. Finally, the ML Inference Host sends an 'Acknowledgement to successful activation' back to the SMO/Non-RT RIC. + +**Figure 4-3. ML model termination procedure** + +For deployment scenario 1.1, where Non-RT RIC acts as inference host, termination/backup activation commands and acknowledgements would be communicated via SMO internal interface. On the other hand, for deployment scenario 1.2, in which AI/ML model is deployed in the Near-RT RIC, whether the termination command and acknowledgement should be + +carried over O1 or A1 is left for further study. Moreover, how SMO/Non-RT RIC could delegate model performance monitoring and the decision making on ML model termination to the Near-RT RIC is also left for further study. Other deployment scenarios, e.g., in which inference host could be in O-CU/O-DU, are FFS. + +## 4.2 Model Design and Composition + +ML model design is the first step to conceiving the initial model. This requires connecting to data sources, parsing messages and tokenizing to create and select features. This activity is offline and requires data exploration mechanisms to help the model designer. + +One question to address for complex problem spaces is whether to design the solution as a single model with many inputs, or as a chain of modular models. These two approaches can be seen in the figures below. + +A chain of models provides a more modular solution that can facilitate reusability. For example, another model X may be shown to produce a better prediction *A-out* by considering an additional input *m*. In such a case, model A can be replaced with model X without the need for retraining or otherwise modifying models B or C. + +On the other hand, in a chaining approach any errors in the prediction *A-out* will be propagated to model C, perhaps resulting in a less accurate prediction C-out than produced by the Single model approach shown below. + +![Figure 4-4: Chained modular models. The diagram shows three models: A, B, and C. Model A has inputs a, b, and c, and produces prediction A-out. Model B has inputs d, e, and f, and produces prediction B-out. Model C takes prediction A-out, prediction B-out, and input g as inputs, and produces prediction C-out.](69d3886ee143a62b445dc3e7f016e64c_img.jpg) + +``` + +graph LR + A[A] -- "prediction A-out" --> C[C] + B[B] -- "prediction B-out" --> C + G[g] -- "inputs" --> C + C -- "prediction C-out" --> Out[C-out] + +``` + +Figure 4-4: Chained modular models. The diagram shows three models: A, B, and C. Model A has inputs a, b, and c, and produces prediction A-out. Model B has inputs d, e, and f, and produces prediction B-out. Model C takes prediction A-out, prediction B-out, and input g as inputs, and produces prediction C-out. + +**Figure 4-4 - Chained modular models** + +A single model allows machine learning to have access to all inputs, which can detect unexpected data relationships and perhaps lead to a more accurate overall model. + +![Figure 4-5: Single model with many inputs. The diagram shows a single model C' that takes all inputs a, b, c, d, e, and f as inputs, and produces prediction C-out.](3d652e008fe48830e7b24028e93a3903_img.jpg) + +``` + +graph LR + A[a] -- "inputs" --> C_prime[C'] + B[b] -- "inputs" --> C_prime + C[c] -- "inputs" --> C_prime + D[d] -- "inputs" --> C_prime + E[e] -- "inputs" --> C_prime + F[f] -- "inputs" --> C_prime + C_prime -- "prediction C-out" --> Out[C-out] + +``` + +Figure 4-5: Single model with many inputs. The diagram shows a single model C' that takes all inputs a, b, c, d, e, and f as inputs, and produces prediction C-out. + +**Figure 4-5 - Single model with many inputs** + +Note that the predicted values *A-out* and *B-out* are not directly available to the single model *C'* whereas they are available to the chained model *C*. However, the model *C'* could be designed to derive these in the same way models *A* and *B* did in the chained approach. + +Note also that inputs *a*, *b*, *c*, *d*, *e* and *f* are not directly available to as inputs to model *C*, only the predicted values *A-out* and *B-out*. If they are not needed, then the chained approach may work well and achieve the desired modularity. In this case one would expect models *C* and *C'* to produce equivalent “*C-out*” predictions. If, however, it turns out that the raw variables *c* and *d* are also useful for a good prediction by model *C*, then the chained approach may not yield as good a prediction as the single model *C'* approach might which has access to those inputs. Of course such a problem could be mitigated by also providing input values *c* and *d* to model *C* as shown below. + +![Figure 4-6: Chained modular models with common inputs. The diagram shows three models: A, B, and C. Model A takes inputs a, b, and c and outputs prediction A-out. Model B takes inputs d, e, and f and outputs prediction B-out. Model C takes inputs g, A-out, and B-out and outputs prediction C-out. There is also a direct input line from g to model C.](70805dbe6f0e6c7423903d383cb47c3d_img.jpg) + +``` + +graph LR + subgraph Inputs + a((a)) + b((b)) + c((c)) + d((d)) + e((e)) + f((f)) + g((g)) + end + subgraph Model_A [A] + A_in[inputs] + end + subgraph Model_B [B] + B_in[inputs] + end + subgraph Model_C [C] + C_in[inputs] + end + A_in --> A_out[prediction A-out] + B_in --> B_out[prediction B-out] + C_in --> C_out[prediction C-out] + a --> A_in + b --> A_in + c --> A_in + d --> B_in + e --> B_in + f --> B_in + g --> C_in + A_out --> C_in + B_out --> C_in + +``` + +Figure 4-6: Chained modular models with common inputs. The diagram shows three models: A, B, and C. Model A takes inputs a, b, and c and outputs prediction A-out. Model B takes inputs d, e, and f and outputs prediction B-out. Model C takes inputs g, A-out, and B-out and outputs prediction C-out. There is also a direct input line from g to model C. + +**Figure 4-6 - Chained modular models with common inputs** + +As an example of a chained model, consider a business problem that attempts to predict when a UE’s serving cell QoE will deteriorate to an unacceptable level, and also predicts when each of the neighbor cell’s QoE reaches an acceptable level. Such a prediction would be used it to determine when to trigger a handover, as well as to select among the various handover cell options. + +One way to design such a solution would be as follows: + +- A: RF signal strength predictor – Predicts RF signal KPIs a UE would experience with a neighbor cell at the current time “*x*”, as well as predict the signal strength that same UE would experience with both its current serving cell and its neighbor cells at time “*x*+ $\Delta$ ”. +- B: Cell utilization predictor – Predicts the cell utilization KPIs for both the serving and neighbor cells above at time “*x*+ $\Delta$ ”. +- C: QoE predictor – Predicts the QoE KPIs that a UE would experience at time “*x*+ $\Delta$ ” for both its current serving and neighbor cells. + +Such a modular approach could be desirable in that other uses for RF signal strength prediction and cell utilization prediction might be envisioned other than to predict UE future QoE. Also, a modular approach would allow each of the prediction models to evolve separately. For example, cell utilization predictor “B” might be improved by including as input trending + +information or venue schedule information among its inputs without having to retrain a single model “C”. Or an RF signal prediction model might be improved based on inputs capturing the UEs predicted travel path based on commute patterns. + +However, in order for such a chained approach to work, the variables available to the QoE predictor must be carefully considered. Whether a chained or a single model approach would be better for solving such a business problem would require analysis that is beyond the intended scope of this paper and will be left as an exercise for the reader. + +## 4.3 Model Runtime Access to Data + +In the prior section we noted that the value of chaining models is the modularity which can be realized. In Figure 4-4 for example, the models A, B, and C could be improved upon and replaced independent of each other. Such modularity could facilitate a marketplace whereby different vendors produce different modular solutions in the predictive space, allowing service providers to select from among the various models with the best predictive abilities for their specific environment. Because such marketplace vendors would want to provide complete solutions and not simply ML models, we will extend the concepts in the last section to apply also to applications. We will thus in this section re-interpret figures Figure 4-4, Figure 4-5, Figure 4-6 as representing applications A, B, C and C’ which contain the models in question. + +Extending the discussion of the prior section, there can be scenarios in which two separate applications require access to the same data. This was seen in Figure 4-6 with applications A and C sharing input c and B and C sharing input d. Because such sharing of inputs may be common it would be wise to avoid an approach in which applications are seen as “owning” data. In addition, independence of the applications is impacted if one is aware of the inputs required of the other. For example, in Figure 4-6 as drawn, application A can be seen as knowing that application C requires Prediction A-out as input. If application C was changed to no longer require Prediction A-out as input, then application A would need to be appropriately modified. Such coupling of applications negatively impacts overall solution modularity. + +Rather, a better paradigm might be one in which data is commonly held by all applications, those applications being granted access to the data that they require. This common repository for the data along with the mechanism for making that data accessible to each application through some mechanism can be thought of as being the “platform” that underlies the “applications.” + +Figure 4-7 illustrates a re-imaging of Figure 4-6 with such an approach in mind + +![Figure 4-7: Chained modular models with common inputs. The diagram shows three applications (Appl A, Appl B, Appl C) interacting with an Inference Host. Appl A has inputs a, b, c and outputs Prediction A-out. Appl B has inputs d, e, f and outputs Prediction B-out. Appl C has inputs Prediction A-out, g and outputs Prediction B-out, Prediction C-out. The Inference Host receives common inputs a, b, c, d, e, f, g and stores outputs a, b, c, d, e, f, g, A-out, B-out, C-out.](b756f94b42598afd4bc2a56ccf7af998_img.jpg) + +Figure 4-7: Chained modular models with common inputs. The diagram shows three applications (Appl A, Appl B, Appl C) interacting with an Inference Host. Appl A has inputs a, b, c and outputs Prediction A-out. Appl B has inputs d, e, f and outputs Prediction B-out. Appl C has inputs Prediction A-out, g and outputs Prediction B-out, Prediction C-out. The Inference Host receives common inputs a, b, c, d, e, f, g and stores outputs a, b, c, d, e, f, g, A-out, B-out, C-out. + +**Figure 4-7 - Chained modular models with common inputs** + +With such an approach, applications can be created independently with their own independent descriptors. When an application is loaded, it could “register” with the Platform to declare what types of data it consumes and what types of data it produces. + +For example, when application A is loaded, its descriptor would be used to declare that it consumes as input variables *a*, *b* and *c* and that it writes *Prediction A-out*. If the consumed variables are standard attributes that the Platform knows how to obtain (e.g., E2 data), it could respond that those input variables are available through the Platform. Later application A could send a formal “subscription” request with more information (such as the specific geographic “scope” from which to collect that input) to have the Platform actually start providing those values. Regarding the produced variables (e.g., *A-out*), the Platform could assign some space in the common data repository for that output to be written. The Platform might also perform some added value validations to ensure that no other registered application also produces/writes that same variable, or if it does to ensure that the two application instances work within different “scopes” (e.g., geography). + +Extending our example, when application C is loaded its descriptor would be used to declare that it reads as input variables *g*, *Prediction A-out* and *Prediction B-out*. Variable *g*, being standard in our example, would be treated as described above. The Platform could also respond that input variable *Prediction A-out* is also available through the Platform. However, if application B had not yet been loaded and registered, the Platform would respond that no source for *Prediction B-out* can be found. Perhaps application C has been written such that *Prediction B-out* is optional input. In this case application C would respond as such and processing would proceed. When application B was later loaded and registered, the Platform could notify all applications of new functionality being available. At that point application C could decide to re-register, again asking for a source for *Prediction B-out*, this time with favorable results. + +Thus, the Platform could provide some added value services to ensure that applications are loaded and registered in the proper order. + +The above described Platform responsibilities with respect to application registration. Now we can address data subscription. + +Let's return to our example in the prior section whereby application A is an RF signal predictor, application B a cell utilization predictor and application C a UE QoE predictor. Perhaps the service provider considers cell utilization prediction to be a fundamental need that should be always "on" for all cells. The service provider would thus configure application B or provide it some policy (e.g., received across an A1-P interface) to generate these predictions, specifying the prediction interval. Application B would then send a "subscribe" request to the Platform asking for variables $d$ , $e$ and $f$ including the desired measurement interval. As part of this "subscription" request Application B would also indicate that it will begin writing *Prediction B-out* with a certain measurement interval. The Platform would determine if these variables are already in the common data repository or not, and if not the Platform would go about securing them (e.g., by sending an E2 SUBSCRIBE request to the appropriate RAN network functions). The Platform would forward to application B the data content found in the data repository that matches that application's subscription request. Upon having secured its input data, application B would continuously be writing *Prediction B-out* to the common data repository. + +For applications A and C, however, perhaps the service provider only wants prediction for a certain set of UEs. One way to accomplish this is for service provider to configure application C or provide it some policy describing the UE set of interest as well as the prediction interval. Application C subscription of its input variable $g$ would proceed with the Platform in the same way as was described above for Application B. Application C would also subscribe to input variables *Prediction A-out* and *Prediction B-out* with a certain measurement interval, the former including a descriptor of the UE set of interest. For *Prediction B-out*, the Platform would determine that those values are already in the common data repository with the desired measurement interval and forward that content to application C. + +For *Prediction A-out*, however, the Platform would determine that there is no data in the common data repository, nor is there any application that has subscribed to write it. The Platform would then identify the application that has registered for writing this data type, in this case application A, and forward to it the subscription request information to that application A. (Note that this is the local equivalent functionality of the Platform sending the E2 SUBSCRIBE request to the RAN for the application B subscription request.) + +Application A would receive the *Prediction A-out* subscription request, including the measurement interval and UE set of interest, and determine what the implications are for its own data needs. It would then send to the Platform a subscription request asking for variables $a$ , $b$ and $c$ along with the measurement interval and UEs of interest. It would also declare its intention to begin writing *Prediction A-out* with a certain measurement interval. Assuming that the Platform does not find this data already in the common data repository, it would go about securing it (e.g., via an E2 SUBSCRIBE request), forwarding the resultant data values to application A. At that point application A would begin writing *Prediction A-out* to the common data repository, which the Platform would in turn begin forwarding to application C. + +## 4.4 Data, Model Training and Model Evaluation pipeline + +This section describes the data, model training and evaluation pipelines. + +![Figure 4-8 - Data pipeline diagram](0ae4658097cb4874d7e46bfbe3c3ff4c_img.jpg) + +The diagram illustrates the data pipeline architecture. On the left, a 'Storage' block contains 'S3', 'Generic Storage', 'Volume', 'Event Bus', and 'Logs'. An arrow points from 'S3' to the 'Extract' block of the 'Data Pipeline'. The 'Data Pipeline' is a horizontal bar containing 'Extract', 'Transform', and 'Load' blocks. Below it, a 'Data Pipeline - Additional Stages' block contains 'Data Analysis' and 'Data Validation' blocks. Arrows show data flow from 'Extract' to 'Transform' to 'Load'. From 'Transform', arrows branch to 'Data Analysis' and 'Data Validation'. From 'Load', arrows branch to 'Data Analysis' and 'Data Validation'. Below 'Data Analysis' is the label 'Data Quality Assessment', and below 'Data Validation' is 'Data Coverage & Fairness Assessment'. Arrows from 'Load' point to 'To Model training pipeline (Training Data)' and 'To Model evaluation pipeline (Testing Data)'. + +Figure 4-8 - Data pipeline diagram + +**Figure 4-8 - Data pipeline** + +Figure 4-8 defines the data pipelines. The “extract-transform-load” (ETL) process describes how data can be extracted from storage, transformed and loaded into training and testing sets. Additional data quality and validation stages can be inserted into the ETL pipeline. Data cleaning can also be part of the Transform block. This is outside the scope of WG2. + +![Figure 4-9 - Model training and evaluation pipelines diagram](4406a126fbb74f39f19a948bbaab5bd2_img.jpg) + +The diagram shows the model training and evaluation pipelines. The 'Model Training Pipeline' is a large box containing 'Representation Exploration', 'Architecture Exploration', and 'Hyperparameter Optimization' blocks. Arrows from 'Representation Exploration' and 'Architecture Exploration' point to 'Hyperparameter Optimization'. An arrow from 'Hyperparameter Optimization' points to 'ML Training Host'. The 'Model Evaluation Pipeline' is a box containing 'Model Evaluation' and 'Model Validation' blocks. An arrow from 'ML Training Host' points to 'Model Evaluation', which then points to 'Model Validation'. An arrow from 'Model Validation' points to 'Deploy'. An arrow from 'From Data Pipeline' points to the 'ML Training Host'. + +Figure 4-9 - Model training and evaluation pipelines diagram + +**Figure 4-9 - Model training and evaluation pipelines** + +Figure 4-9 shows the model training and evaluation pipelines. Model training pipeline may change with model types. Model evaluation pipeline, however, is a more generic process. Model evaluation can be used to evaluate a single model or extended to select the best model from a range of models. + +The end-to-end training process includes the following + +- Fulfills the data requirements of the model (format, sample distribution, extent) +- Connects with requisite data via Data Pipeline (simplest ex: a data broker) +- Partitions data into appropriate sets (training, validation, testing, sample) +- Keeps Training data cached for error recovery and subsequent usage +- Manages model training through all phases + +- Implements training by invoking a Model Training Pipeline +- Training Client tunes model parameters during training phases +- Scoring client monitors performance in order to declare training phase complete +- Communicates with license manager for usage and versioning + +## 4.5 ML Model Lifecycle Implementation Example + +The section provides an example (see Figure 4-10) of ML model lifecycle implementation example and key phases involved in the design and deployment in O-RAN architecture. + +![Figure 4-10 - ML model lifecycle (an implementation example). The diagram illustrates the ML model lifecycle across O-RAN components. It starts with an ML Designer (1) creating a Design Model, which is then deployed as an Untrained Model (2) to ML Training Hosts. The hosts use a Training Model and Data Broker DB to train and retrain models. The trained models are then uploaded to the ML Catalog (4). The ML Designer also publishes models to the Non-RT RIC (5). The Non-RT RIC packages models and sets policies (6) and interacts with the ML model Catalog. The Non-RT RIC also interacts with the Near-RT RIC (7) via O1 (CM, deploy models) and A1 (policies for models). The Near-RT RIC interacts with O-CU-CP and O-CU-UP (8) via O1 (FM, PM). The O-CU-CP and O-CU-UP interact with O-DU via F1. The O-DU interacts with O-RU via Open Front Haul. The O-RU interacts with the ML models (loop 1). The O-DU also interacts with the ML models (loop 2). The O-CU-CP and O-CU-UP interact with the ML models (loop 3). The O-CU-CP and O-CU-UP interact with the ML models (loop 4). The O-CU-CP and O-CU-UP interact with the ML models (loop 5). The O-CU-CP and O-CU-UP interact with the ML models (loop 6). The O-CU-CP and O-CU-UP interact with the ML models (loop 7). The O-CU-CP and O-CU-UP interact with the ML models (loop 8). The O-CU-CP and O-CU-UP interact with the ML models (loop 9). The O-CU-CP and O-CU-UP interact with the ML models (loop 10). The O-CU-CP and O-CU-UP interact with the ML models (loop 11). The O-CU-CP and O-CU-UP interact with the ML models (loop 12). The O-CU-CP and O-CU-UP interact with the ML models (loop 13). The O-CU-CP and O-CU-UP interact with the ML models (loop 14). The O-CU-CP and O-CU-UP interact with the ML models (loop 15). The O-CU-CP and O-CU-UP interact with the ML models (loop 16). The O-CU-CP and O-CU-UP interact with the ML models (loop 17). The O-CU-CP and O-CU-UP interact with the ML models (loop 18). The O-CU-CP and O-CU-UP interact with the ML models (loop 19). The O-CU-CP and O-CU-UP interact with the ML models (loop 20).](99e825c7c0e1382f451d57cf6164fe25_img.jpg) + +\* ML Training Host can be part of non-RT RIC or can be executed offline + +Figure 4-10 - ML model lifecycle (an implementation example). The diagram illustrates the ML model lifecycle across O-RAN components. It starts with an ML Designer (1) creating a Design Model, which is then deployed as an Untrained Model (2) to ML Training Hosts. The hosts use a Training Model and Data Broker DB to train and retrain models. The trained models are then uploaded to the ML Catalog (4). The ML Designer also publishes models to the Non-RT RIC (5). The Non-RT RIC packages models and sets policies (6) and interacts with the ML model Catalog. The Non-RT RIC also interacts with the Near-RT RIC (7) via O1 (CM, deploy models) and A1 (policies for models). The Near-RT RIC interacts with O-CU-CP and O-CU-UP (8) via O1 (FM, PM). The O-CU-CP and O-CU-UP interact with O-DU via F1. The O-DU interacts with O-RU via Open Front Haul. The O-RU interacts with the ML models (loop 1). The O-DU also interacts with the ML models (loop 2). The O-CU-CP and O-CU-UP interact with the ML models (loop 3). The O-CU-CP and O-CU-UP interact with the ML models (loop 4). The O-CU-CP and O-CU-UP interact with the ML models (loop 5). The O-CU-CP and O-CU-UP interact with the ML models (loop 6). The O-CU-CP and O-CU-UP interact with the ML models (loop 7). The O-CU-CP and O-CU-UP interact with the ML models (loop 8). The O-CU-CP and O-CU-UP interact with the ML models (loop 9). The O-CU-CP and O-CU-UP interact with the ML models (loop 10). The O-CU-CP and O-CU-UP interact with the ML models (loop 11). The O-CU-CP and O-CU-UP interact with the ML models (loop 12). The O-CU-CP and O-CU-UP interact with the ML models (loop 13). The O-CU-CP and O-CU-UP interact with the ML models (loop 14). The O-CU-CP and O-CU-UP interact with the ML models (loop 15). The O-CU-CP and O-CU-UP interact with the ML models (loop 16). The O-CU-CP and O-CU-UP interact with the ML models (loop 17). The O-CU-CP and O-CU-UP interact with the ML models (loop 18). The O-CU-CP and O-CU-UP interact with the ML models (loop 19). The O-CU-CP and O-CU-UP interact with the ML models (loop 20). + +**Figure 4-10 - ML model lifecycle (an implementation example)** + +Note: ML Model capability query and discovery can occur in ML designer and Non-RT RIC. + +The typical steps involved in AI/ML based use-case application in O-RAN architecture is shown in Figure 4-10 considering supervised/unsupervised learning ML models. The steps for reinforcement model could vary with respect to ML training host and the related interaction flows. + +1. ML Modeler uses a designer environment along with ML toolkits (e.g., scikit-learn, R, H2O, Keras, TensorFlow) to create the initial ML model +2. The initial model is sent to training hosts for training +3. The appropriate data sets are collected from the Near-RT RIC, O-CU and O-DU to a data lake and passed to the ML training hosts. +4. The trained model/sub models are uploaded to the ML designer catalog (one such open source catalog platform is AcumosAI). The final ML model is composed. + +![O-RAN Alliance Logo](91958aa06a82d00903e46a81fe41189e_img.jpg) + +O-RAN.WG2.AIML-v01.03 + +- The ML model is published to Non-RT RIC along with the associated license and metadata. +- Non-RT RIC creates a containerized ML application containing the necessary model artifacts (when using AcumosAI, the ML model's container is created in Acumos catalog itself). +- Non-RT RIC deploys the ML application to the Near-RT RIC, O-DU and O-CU using the O1 interface. Policies are also set using the A1 interface. +- PM data is sent back to ML training hosts from Near-RT RIC, O-DU and O-CU for retraining. + +Note that Near-RT RIC can also update ML model parameters at runtime (e.g., gradient descent) without going through extensive retraining. Training hosts and ML designers can also be part of Non-RT RIC. + +# Chapter 5 Deployment Scenarios + +This chapter describes the high-level architecture of deployment scenarios defined in Section 5.1 and also captures the sequence diagrams to show end-to-end flows. + +The current version captures the deployment scenarios 1.1 (see Figure 5-1), scenarios 1.2 (see Figure 5-2), scenarios 1.3 (see Figure 5-3), scenario 1.4 (see Figure 5-4). + +![Figure 5-1 - Deployment scenario 1.1 - AI/ML training and inference host locations](da1448617d22e06e288d94da0df507bc_img.jpg) + +Case 1.1 AI/ML Continuous Operation/AI/ML Model Management/Data Preparation/AI/ML Training and AI/ML Inference are all in Non-RT RIC. + +Figure 5-1 - Deployment scenario 1.1 - AI/ML training and inference host locations + +**Figure 5-1 - Deployment scenario 1.1 - AI/ML training and inference host locations** + +Copyright © 2021 by the O-RAN Alliance e.V. Your use is subject to the terms of the O-RAN Adopter License Agreement in the Annex Z. + +34 + +Case 1.2 AI/ML Continuous Operation/ Data Preparation(for training)/AI/ML Training are in Non-RT RIC +AI/ML Model Management is out of Non-RT RIC(in or out of SMO). +Data Collection(for inference)/Data Preparation(for inference)/AI/ML Inference is in Near-RT RIC. + +![Figure 5-2: Deployment scenario 1.2 -- AI/ML training and inference host locations. The diagram shows the interaction between O-DU/O-CU, SMO, Non-RT RIC, and Near-RT RIC. O-DU/O-CU sends ML Training info (O1) to Data Collection in Non-RT RIC. Data Collection sends AI/ML Training Data to Data Preparation, which then sends it to AI/ML Training. AI/ML Training sends Model Certification/On-boarding to AI/ML Model Management. AI/ML Model Management sends guide/feedback to AI/ML Continuous Operation and ML performance feedback (A1) to AI/ML Inference. AI/ML Inference sends AI/ML Inference Data to Data Preparation in Near-RT RIC, which then sends AI/ML Online info (E2) to O-DU/O-CU. O-DU/O-CU sends Control action/guidance over E2 (8) to AI/ML Inference.](845a2970be7ca164d34031810a824e33_img.jpg) + +Figure 5-2: Deployment scenario 1.2 -- AI/ML training and inference host locations. The diagram shows the interaction between O-DU/O-CU, SMO, Non-RT RIC, and Near-RT RIC. O-DU/O-CU sends ML Training info (O1) to Data Collection in Non-RT RIC. Data Collection sends AI/ML Training Data to Data Preparation, which then sends it to AI/ML Training. AI/ML Training sends Model Certification/On-boarding to AI/ML Model Management. AI/ML Model Management sends guide/feedback to AI/ML Continuous Operation and ML performance feedback (A1) to AI/ML Inference. AI/ML Inference sends AI/ML Inference Data to Data Preparation in Near-RT RIC, which then sends AI/ML Online info (E2) to O-DU/O-CU. O-DU/O-CU sends Control action/guidance over E2 (8) to AI/ML Inference. + +Figure 5-2 Deployment scenario 1.2 -- AI/ML training and inference host locations + +Case 1.3 AI/ML Continuous Operation/AI/ML Inference are in Non-RT RIC.Data Preparation/AI/ML Training/ AI/ML Model Management are out of Non-RT RIC(in or out of SMO). + +![Figure 5-3: Deployment scenario 1.3 - AI/ML training and inference host locations. The diagram shows the interaction between O-DU/O-CU, SMO, Non-RT RIC, and Near-RT RIC. O-DU/O-CU sends ML Training info (O1) to Data Collection in Non-RT RIC. Data Collection sends AI/ML Training Data to Data Preparation, which then sends it to AI/ML Training. AI/ML Training sends Model Certification/On-boarding to AI/ML Model Management. AI/ML Model Management sends guide/feedback to AI/ML Continuous Operation and ML performance feedback (A1) to AI/ML Inference. AI/ML Inference sends AI/ML Inference Data to Data Preparation in Non-RT RIC, which then sends AI/ML Online info (O1) to O-DU/O-CU. O-DU/O-CU sends Control action/guidance over E2 (8) to AI/ML Inference.](b762b1bcda4cd7d5d6e45d8679545f37_img.jpg) + +Figure 5-3: Deployment scenario 1.3 - AI/ML training and inference host locations. The diagram shows the interaction between O-DU/O-CU, SMO, Non-RT RIC, and Near-RT RIC. O-DU/O-CU sends ML Training info (O1) to Data Collection in Non-RT RIC. Data Collection sends AI/ML Training Data to Data Preparation, which then sends it to AI/ML Training. AI/ML Training sends Model Certification/On-boarding to AI/ML Model Management. AI/ML Model Management sends guide/feedback to AI/ML Continuous Operation and ML performance feedback (A1) to AI/ML Inference. AI/ML Inference sends AI/ML Inference Data to Data Preparation in Non-RT RIC, which then sends AI/ML Online info (O1) to O-DU/O-CU. O-DU/O-CU sends Control action/guidance over E2 (8) to AI/ML Inference. + +Figure 5-3 Deployment scenario 1.3 - AI/ML training and inference host locations + +![Figure 5-4 - Deployment scenario 1.4 - ML training and inference host locations. The diagram shows the interaction between O-CU/O-DU, SMO/Non-RT RIC, and Near-RT RIC. O-CU/O-DU provides data for offline training (O1) to SMO/Non-RT RIC ML Training, and data for online learning (E2) and inference (E2) to Near-RT RIC ML Training and ML Inference. SMO/Non-RT RIC ML model repository stores models. Near-RT RIC ML Training receives model updates from the repository and provides performance feedback to ML Inference. ML Inference provides ML Training Info for online learning to ML Training. Control action/guidance (E2) is sent from ML Inference to O-CU/O-DU.](8119eb3869ff0848506e9a495af2a564_img.jpg) + +Figure 5-4 - Deployment scenario 1.4 - ML training and inference host locations. The diagram shows the interaction between O-CU/O-DU, SMO/Non-RT RIC, and Near-RT RIC. O-CU/O-DU provides data for offline training (O1) to SMO/Non-RT RIC ML Training, and data for online learning (E2) and inference (E2) to Near-RT RIC ML Training and ML Inference. SMO/Non-RT RIC ML model repository stores models. Near-RT RIC ML Training receives model updates from the repository and provides performance feedback to ML Inference. ML Inference provides ML Training Info for online learning to ML Training. Control action/guidance (E2) is sent from ML Inference to O-CU/O-DU. + +**Figure 5-4 - Deployment scenario 1.4 - ML training and inference host locations** + +In deployment scenario 1.4, the AI/ML model is first offline trained by training host in the SMO/Non-RT RIC. Training host in the Near-RT RIC is used for continuous online learning, and ML inference host is located as part of the Near-RT RIC. ML model repository in the SMO/Non-RT RIC is used to save backup ML training models. When the ML training host in the Near-RT RIC observes severe performance degradation, it can request the stored (previously well-performing) AI/ML model from model repository in the SMO/Non-RT RIC. Based on the retrieved ML model from SMO/Non-RT RIC, the training host in the Near-RT RIC updates the online model using the input data over E2 and from the ML inference host. + +The interactions among various functional blocks are described as follows. Note that the learning workflow does not strictly follow the sequence of descriptions. + +1. O-CU/O-DU data for offline training is collected over O1 interface and the initial offline model is trained in the SMO/Non-RT RIC. +2. The offline trained model or the backup model is moved to the Near-RT RIC. +3. The AI/ML model is deployed to the ML inference host in the Near-RT RIC. +4. O-CU/O-DU data for inference in the Near-RT RIC is collected over E2 interface. +5. The ML inference host performs inference using the deployed model and collected O-CU/O-DU data. +6. The ML inference host enforces control action/guidance via E2 interface. +7. O-CU/O-DU data for online learning in the Near-RT RIC is collected over E2 interface. +8. The ML inference host provides performance feedback to the ML training host in the Near-RT RIC for monitoring and training data for online learning. +9. The ML training host in the Near-RT RIC updates the model. +10. A well-performing model can be added to the model repository. + +Note 1: O-CU/O-DU data collected over O1 for offline training and O-CU/O-DU data collected over E2 for online learning and/or inference can be different. + +Note 2: The model online update frequency can be different from the E2 update frequency. + +Note 3: Deployment scenario 1.4 is essential to enable online RL in the Near-RT RIC. However, it is not exclusive for online RL. + +### 1 5.1 Sequence Diagram for Deployment Scenarios 1.1 and 1.2 + +2 The sequence diagram (seeFigure 5-5) for Deployment Scenario-1.1 (SMO/Non-RT RIC for model training, Non-RT RIC for +3 model inference host) and Deployment Scenario-1.2 (SMO/Non-RT RIC for model training, Near-RT RIC as model inference +4 host) is captured below + +![Sequence diagram for ML model lifecycle in O-RAN architecture. The diagram shows interactions between Personnel (ML Model Designer), Service Management and Orchestration (SMO), and O-RAN components (near-RT RIC, O-CU, O-DU/O-RU). The lifecycle is divided into four main phases: 1. ML model Query/Discovery, 2. ML model Selection and Training, 3. ML model Deployment and Inference, and 4. ML model Performance Monitoring. The diagram includes numerous numbered messages (e.g., 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45) and conditional blocks (alt) for different scenarios. Key components involved include Orchestration, Collector, Resource Controller, Data Lake, non-RT RIC, ML Training Host(s), near-RT RIC, O-CU, and O-DU/O-RU. The diagram also shows a feedback loop for model updates and redeployment.](1c97a7eeecd5f2e5e4eca1c3ca5549e9_img.jpg) + +Sequence diagram for ML model lifecycle in O-RAN architecture. The diagram shows interactions between Personnel (ML Model Designer), Service Management and Orchestration (SMO), and O-RAN components (near-RT RIC, O-CU, O-DU/O-RU). The lifecycle is divided into four main phases: 1. ML model Query/Discovery, 2. ML model Selection and Training, 3. ML model Deployment and Inference, and 4. ML model Performance Monitoring. The diagram includes numerous numbered messages (e.g., 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45) and conditional blocks (alt) for different scenarios. Key components involved include Orchestration, Collector, Resource Controller, Data Lake, non-RT RIC, ML Training Host(s), near-RT RIC, O-CU, and O-DU/O-RU. The diagram also shows a feedback loop for model updates and redeployment. + +**Figure 5-5 - Non-RT RIC as ML training host, Non-RT RIC or Near-RT RIC as ML inference host (Note that the SMO components are defined in WG1 OAM architecture, Appendix B [i.x9])** + +## 5.2 Criteria for Determining Deployment Scenario (Options) + +This section discusses some criteria that can be used to decide whether an ML Application should execute in a Non-RT RIC or Near-RT RIC Inference Host. It also discusses some criteria for whether an ML Model within such an ML Application should be initially trained (offline learning) in a Non-RT RIC as its Training Host, or in a more centralized or remote location. (Note that subsequent online learning would be expected to occur in the execution environment.) Considerations for these decisions relate to the amount of data that is required by the ML Model both in training as well as in execution, as well as latency considerations in execution. It is assumed in this section that the type of data that an ML Model requires at runtime will also be required, perhaps in aggregated form, during training. + +It is assumed that the Near-RT RIC would not be a suitable candidate for offline Training Host. Initial training would typically require a large pool of compute and storage resources. The very nature of the Near-RT RIC as a Network Function is geared towards high performance runtime processing with a small footprint. It is unlikely to have sufficient compute and storage resources to also handle initial offline learning. In addition, offline learning at the Near-RT RIC would also introduce complexity into its design to provide the assurances that ML training would not affect its runtime network function processing. The Non-RT RIC functionality of the SMO, a management (as opposed to a network) function, seems better suited to host initial training. + +Regarding the Inference Host decision, criteria include: + +1. The availability of data across a given interface. For example, if the data needed at execution time is available only across the E2 interface, then either the ML Application that includes this ML Model must either consider the Near-RT RIC as its Inference Host, or a Near-RT RIC function must be employed to forward across the O1 interface that E2 data to the Non-RT RIC as Inference Host. If the data needed at execution time is available only across the O1 interface, then the ML Application would need to consider the Non-RT RIC as its Inference Host, or a Non-RT RIC function must be employed to forward that O1 data to the Near-RT RIC with its own O1 interface. Clearly some of these options are very inefficient and likely undesirable. +2. The cost of data movement. Obviously the data movement costs of the various choices described in #1 above differ from one another. Ideally, if an ML Model requires E2 data, the Inference Host of its associated ML Application would be the Near-RT RIC. Similarly, if an ML Model requires O1 data, the Inference Host of its associated ML Application would be the Non-RT RIC. If an ML Model requires E2 data but considers the Non-RT RIC to be its Inference Host, then some function within the Near-RT RIC would need to be used as a vehicle to forward that E2 data to the Non-RT RIC. This would obviously be inefficient and costly. However, if the Non-RT RIC is also the Training Host for ongoing learning of that ML Model, then perhaps this inefficiency and cost would be warranted. Less understandable would be using the Non-RT RIC as a vehicle to forward O1 data to the Near-RT RIC acting as Inference Host. +3. Latency considerations. The data latency associated with the various choices described in #1 above differ from one another, and the Loop 2 versus Loop 3 considerations will factor heavily into whether a ML Model consider its Inference Host to be a Near-RT RIC or a Non-RT RIC. +4. Compute resource availability considerations. The Near-RT RIC may run in an “edge” location where compute resources are very limited and hence expensive. The Non-RT RIC may more likely run in a location with more ready access to compute resources, such as a data center. + +Regarding the initial Training Host decision, criteria include: + +1. The local versus general significance of the data. A data lake will be required in order to train an ML Model. Assuming that a typical Service Provider will have more than one Non-RT RIC instance, if that training data lake coincides with the Non-RT RIC then the data lake will contain data of only local significance. Only by merging this “local data” from many locales into a “central data lake” could future ML applications perhaps find unexpected correlations within data that was incorrectly assumed to be of only local significance. +2. The cost of data movement. While the previous item discussed the benefits of a “central data lake”, transporting “local data” to such a central location is not without its costs. + +Thus the decision as to whether to use a “local” Non-RT RIC as an initial (offline) Training Host or not in large part depends on the service provider’s assessment of the value of that training data for more general purposes. The results of such an assessment can clearly differ from one service provider to another. + +Looking at the criteria above, one can see how the decision as to whether the appropriate Inference Host for an ML model is a Non-RT RIC or a Near-RT RIC can reasonably differ between Service Providers. For example, consider two service providers below in their assessment of how to deploy a ML Application “X” that takes large volumes of E2 data to calculate some “enrichment information” regarding UEs (e.g., the UE’s predicted QoE on various cells measured on the order of seconds), which can be used by a different “traffic steering” application (perhaps not ML-enabled) to appropriately drive handovers of those UEs. Assume that the “traffic steering” application would run at the Near-RT RIC using E2 mechanisms to drive handovers. Service Provider A and Service Provider B may come to quite different conclusions of how to deploy such an ML Application “X”: + +| Service Provider A | | Service Provider B | +|------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| “X” Data Source | E2 | E2 | +| “X” Data Movement Cost | Very High Volume, Very High Cost to Move Data over Distance | Very High Volume, Very High Cost to Move Data over Distance | +| “X” Latency Consideration | Loop 3 acceptable | Loop 3 acceptable | +| “X” Training data evaluation | This E2 data is of only local significance. | This E2 data is of potential global significance. Willing to pay to move data to a central data lake. | +| Pertinent Business Considerations | Minimize data transport costs for data with only local significance.

    Reserve Near-RT RIC for applications requiring Loop 2 latency | Any application requiring E2 data should run on the Near-RT RIC. Do not use Near-RT RIC as a data relay to the Non-RT RIC. | +| Inference Host Decision | Because “X” requires only Loop 3 latency, deploy it as an ML Application using the Non-RT RIC as its Inference Host. “X” will communicate with the “traffic steering” application via A1-E1. | Because it requires E2 data, “X” will run as an ML Application using the Near-RT RIC as its Inference Host. “X” will communicate with the “traffic steering” application via Near-RT RIC internal mechanisms. | +| Runtime E2 Data Movement | RAN -> E2 -> Near-RT RIC -> O1 -> Non-RT RIC | RAN -> E2 -> Near-RT RIC | +| Initial (Offline) Training Host Decision | Non-RT RIC will be used for training “X” (local training) | A central off-line location will be used for training “X” (training on a central data lake) | + +| | | | +|---------------------------------------------|-------------------------------------------------------------------------------------------|-----------------------------------------------------| +| Initial (Offline) Training E2 Data Movement | RAN -> E2 -> Near-RT RIC -> O1 -> Non-RT RIC (leverage the Runtime E2 Data Movement path) | RAN -> Offline Data Collection -> Central Data Lake | +|---------------------------------------------|-------------------------------------------------------------------------------------------|-----------------------------------------------------| + +1 + +2 + +3 + +4 + +5 + +6 + +7 + +8 + +9 + +10 + +Because the mechanism of inter-ML application communication (e.g., A1 versus Near-RT RIC internal) is so sensitive to considerations that can reasonably differ among service providers, it will be useful if the mechanism used were only a deployment decision. This should be kept in mind when the A1 and Near-RT RIC internal interface mechanisms are defined. To illustrate this extending the example above, if the mechanism for having the ML model “X” communicate with the “traffic steering” application is through a data structure capturing predicted QoE for a given UE on various cells, this data structure could be communicated either as “enrichment information” via A1-EI or communicated via a common data repository on the Near-RT RIC (such as described in section 4.3). Such an approach could preserve the service provider’s ability to make the choice of inference host a deployment consideration that does not require extensive refactoring or retraining of the solution components. + +# Chapter 6 Requirements + +## 6.1 Functional Requirements + +This section describes the functional requirements for A1 interface and Non-RT RIC. + +| | | +|-----------------------|---------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN1] | Non-RT RIC may request/trigger ML model training in training hosts. | +|-----------------------|---------------------------------------------------------------------| + +Notes: Regardless of where the model is deployed and executed, non-RT RIC should request/trigger ML model training. Note that ML models may be trained and not currently deployed. Implicitly, model re-training and model performance/evaluation. + +| | | +|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN2] | Non-RT RIC shall provide a query able catalog for ML designer to publish/install trained ML models (executable software components) and Non-RT RIC will provide discovery mechanism if a particular ML model can be executed in the target ML inference host (MF), and what number (and type) of ML models can be executed in the MF. | +|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Notes: Non-RT RIC is a component of the SMO framework, i.e., one component of the NMS. The catalogue is not only for external ML market place or platform to publish the models, but also the source for any internal models as well. Non-RT RIC can also connect to external ML catalogues via SMO specific interfaces (interface specification is not in scope of document). There are three types of catalogs namely (design-time catalog (outside non-RT RIC in other ML platforms), training/deployment-time catalog (inside non-RT RIC), and run-time catalog (inside near-RT RIC for scenario 1.2)). In scenario 1.1 where ML models are trained, deployed and executed in non-RT RIC. + +| | | +|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN3] | Non-RT RIC shall support necessary capabilities (enable executable software to be installed, e.g., containers) for ML model inference in support of ML assisted solutions running in non-RT RIC | +|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Notes: ML engines are packaged s/w executable libraries that provide the necessary routines to run the model. + +Note: As an example, policies to switch and activate ML model instances under different operating conditions (busy hour vs non-busy hour or seasonal changes, etc.) + +| | | +|-----------------------|------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN4] | Non-RT RIC shall be able to access feedback data over O1 interface on ML model performance and perform necessary evaluation. | +|-----------------------|------------------------------------------------------------------------------------------------------------------------------| + +Note: PM and FM stats for ML model are relayed over O1. If the ML model fails during runtime an alarm can be generated as feedback to non-RT RIC. How well the ML model is performing in terms of accuracy of prediction or other operating statistics it produces can be sent to non-RT RIC over O1. + +Note: The following requirements which apply to both the Non-RT RIC and the Near-RT RIC as ML Inference Host are intended to facilitate a Service Provider's ability to consider it a deployment decision whether an ML Application should be + +run on a Non-RT RIC or a Near-RT RIC as its Inference Host. This is in recognition that the criteria for determining the deployment scenario for a given ML Application may differ between service providers. See Section 5.2 for a discussion on the types of criteria that may be weighed differently by different providers + +| | | +|-------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN5]
    [REQ-Near-RT RIC-FUN1] | As part of ML Application “registration”, the ML Inference Host shall be able to digest information relating the data type(s) and periodicity thereof that the ML Application produces and consumes. This requirement applies both to the Non-RT RIC function and the Near-RT RIC as ML Inference Host. | +|-------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Note: The following is the corresponding requirement as applied to ML Applications. + +| | | +|-------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN6]
    [REQ-Near-RT RIC-FUN2] | ML Applications shall be able to perform “registration” interactions with the ML Inference Host communicating information relating the data type(s) and periodicity thereof that the ML Application produces and consumes. This requirement applies both to those ML Applications that consider the Non-RT RIC function as ML Inference Host, as well as those ML Applications that consider the Near-RT RIC as ML Inference Host. | +|-------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Note: “Registration” differs from “subscription” in that “registration” involves only data types and their periodicity, whereas “subscription” involves specific sets of data within a given “scope” (see next requirement). + +| | | +|-------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN7]
    [REQ-Near-RT RIC-FUN3] | The ML Inference Host will be able to match data consumption needs with data sources. In this respect a data source could be either an ML Application (i.e., another ML Application’s data “produced”) or the ML Inference Host itself (e.g., mediating an O1-VES data source via the SMO). The ML Inference Host shall consider it a registration-time validation error if no corresponding source can be matched to an ML application’s “consumed data” requirements. This requirement applies both to the Non-RT RIC function and the Near-RT RIC as ML Inference Host. | +|-------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Note: The following requirements referring to ML Inference Host handling of data “subscription requests” are intended to allow ML Applications to share data without knowing each other’s data needs (see sections 4.2 and 4.3). This functionality is seen as an enabler for modularity of ML Applications. + +| | | +|-------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN8]
    [REQ-Near-RT RIC-FUN4] | The ML Inference Host shall be able to process scoped data “subscription” requests from ML Applications, working with other neighboring (i.e., SMO, Non-RT RIC function, Near-RT RIC Platform) functions as necessary to set up the corresponding data routing (e.g., routing of O1-VES data to the ML Application, routing of one ML Application’s produced data to the consuming ML Application). This requirement applies both to the Non-RT RIC function and the Near-RT RIC as ML Inference Host. | +|-------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Note: An example of “scope” for a data subscription request would be identifying a specific set of gNBs from which to collect O1 data of a particular data type. + +| | | +|-------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN9]
    [REQ-Near-RT RIC-FUN5] | For subscription requests that correspond to data produced by another ML Application, the ML Inference Host function will pass the information content thereof (e.g., data type, scope, periodicity) to that other ML Application for processing. This requirement applies both to the Non-RT RIC function and the Near-RT RIC as ML Inference Host. | +|-------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +1 + +| | | +|--------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN10]
    [REQ-Near-RT RIC-FUN6] | ML Applications that produce data shall be able to interact with the ML Inference Host to receive and process scoped subscription requests. The ML Application will be responsible for determining and generating to the ML Inference Host any additional subscription requests needed to produce the requested data. This requirement applies both to those ML Applications that consider the Non-RT RIC function as ML Inference Host, as well as those ML Applications that consider the Near-RT RIC as ML Inference Host. | +|--------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +2 + +3 + +4 + +Note: It is the responsibility of the ML Application to ensure that the periodicity and scope of these “consumed data” subscription request corresponds to that ML Application’s needs in producing the requested data, as described in the scoped subscription request that it received from the Inference Host. + +5 + +| | | +|--------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN11]
    [REQ-Near-RT RIC-FUN7] | The ML Inference Host shall be able to provide data mediation functionality such that, if two separate ML Applications request the same ML Application-produced data, the ML Inference Host will split the data feed without placing a burden on the source ML Application. This requirement applies both to the Non-RT RIC function and the Near-RT RIC as ML Inference Host. | +|--------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +6 + +| | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN12] | Non-RT RIC shall have access to termination conditions, and it shall be able to compute related performance metrics specified in termination conditions, compare performance monitoring results against termination conditions, and make judgement that whether termination procedure should be triggered. | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +7 + +| | | +|--------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-Non-RT RIC-FUN13]
    [REQ-Near-RT RIC-FUN8] | The ML inference host shall be able to receive ML model termination command, identify the problematic model according to the request, and terminate it accordingly. ML inference host shall be able to receive backup solution activation command, and switch to the backup solution following the instruction. ML inference host shall notify SMO/Non-RT RIC about the outcome of ML model termination and the activation of backup solution via acknowledgement messages. | +|--------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +8 + +9 + +| REQ | Description | +|---------------|--------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-O1-FUN1] | O1 interface shall support deployment and update of the ML models as a packaged s/w executable (e.g., in a container). | +| [REQ-O1-FUN2] | O1 interface shall support file based ML model deployment and updates. | +| [REQ-O1-FUN3] | O1 interface shall support PM and FM data collection for ML models, including fine-grained events/counters needed for ML training and inference. | +| [REQ-O1-FUN4] | O1 interface shall support collection of ML relevant capabilities of the managed function where the model is to be deployed for inference. | + +## 6.2 Non-Functional Requirements + +This section describes the non-functional requirements for A1 interface and Non-RT RIC, e.g., security. + +| REQ | Description | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-O1-NONFUN1] | O1 interface shall support scaling ML model instances running in target ML inference host (MF) by observing resource utilization in MF. | + +Note: The environment where the ML model instance is running will monitor resource utilization (e.g., in O-RAN-SC there is a component call Resource Monitor in near-RT RIC; similarly, in non-RT RIC there needs to be a Resource Monitor that continuously monitors resource utilization). If resources are low or fall below a certain threshold, the runtime environment in near-RT RIC and non-RT RIC needs to provide a scaling mechanism to add more ML instances. K8s runtime environments typically provide auto-scaling feature. + +| REQ | Description | +|------------------|--------------------------------------------------------------------------------------------------------------------------------| +| [REQ-O1-NONFUN2] | ML model instances running in target ML inference hosts shall be automatically scaled by observing resource utilization in MF. | + +# Chapter 7 Key Issues + +## 7.1 AI/ML Models in O-RAN Use Cases + +In [4] multiple AI/ML assisted use cases are discussed. This section summarizes the examples of the AI/ML models used in the O-RAN use cases. + +| Use Case | AI/ML models functionality description | AI/ML algorithms types (example) | Deploy scenarios mapping | Data Input | Data Output | +|------------------|---------------------------------------------------------------------|-------------------------------------------|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------| +| QoE Optimization | service type classification | Supervised learning (e.g., CNN, DNN) | Scenario 1.2 | user traffic data | service type | +| | KQI/QoE prediction (e.g., good, bad or video stall ratio, duration) | Supervised learning (e.g., LSTM, XGboost) | Scenario 1.2 | Network data:

    L2 measurement report related to traffic pattern, e.g., throughput, latency, packets per-second

    UE level radio channel information, mobility related metrics

    RAN protocol stack status: e.g. PD CP buffer status

    Cell level information: e.g. DL/UL PRB occupation rate

    Application data: e.g., video QoE score, video initial delay | KQI/QoE value e.g., good/bad, stalling ratio, video stalling duration, vMoS value | + +| | | | | | | +|----------------------------|---------------------------------------------------------------------------------------|--------------------------------------------------------------------|-----------------------------|----------------------------------------------------------------------------|------------------------------------------------------------------------| +| | | | | stalling detail including the timestamp stalling duration, stalling ratio, | | +| | Available radio bandwidth prediction | Supervised learning (e.g., DNN) | Scenario 1.2 | similar to above | Available radio B bandwidth | +| Traffic Steering | cell load prediction/user traffic volume prediction | Supervised learning (time series prediction, e.g., SVR, DNN) | Scenario 1.1 / Scenario 1.2 | load related counters, e.g., UL/DL PRB occupation | same to input | +| | Radio finger print prediction | supervised learning (e.g., SVR, GBDT) | Scenario 1.2 | Intra-frequency MR data and PM counters, e.g., RSRP, RSRQ, MCS, CQI, etc. | Inter-frequency MR data, e.g., RSRP, RSRQ, MCS, CQI, etc. | +| QoE based Traffic Steering | generate relevant AI policies to provide guidance on the traffic steering preferences | FFS | Scenario 1.1 | FFS | priority order of the cells to be used for downlink data transmission. | +| | time-series prediction of individual performance metrics or counters | Supervised learning (e.g. lasso regression-based prediction model) | Scenario 1.2 | FFS | FFS | +| | QoE prediction at each neighbor cell for a given targeted user | Supervised learning (e.g., binary classification) | Scenario 1.2 | FFS | QoE good/bad | + +| | | | | | | +|-----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------|--------------|------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------| +| | | model using
    Random Forest) | | | | +| V2X
    Handover
    Managem
    ent |
    • ✓ prediction / detection
      HO anomalies
    • ✓ discovery of preferred
      HO sequences
    | Supervised
    learning | Scenario 1.2 | CAM,,radio cell
    IDs, connection
    IDs, and basic
    radio
    measurements
    (RSRP, RSPQ
    etc.)

    GPS, direction,
    velocity |
    • ✓ HO anomalies
      probability
    • ✓ preferred HO
      sequences
    | + +**Note:** CAM stands for Cooperative Awareness Message, as defined in [6]. It originates from the vehicular UE and terminates in the V2X App Server. It contains the GPS coordinates of the vehicle to a 0.1-1s granularity. + +## 7.2 AI/ML Model Deployment + +In deployment scenario 1.2, Non-RT RIC acts as the ML model training host and near-RT RIC acts as the ML model inference host. ML/AI model can be deployed and enabled in Near-RT RIC in different options: + +1. Image based deployment: The AI/ML model will be deployed as a xAPP or within a xAPP instance, and also can be updated via the xAPP software update. In this case, the ML inference runtime is self-contained in the image, which simplifies the deployment. This is a generic deployment of ML xAPP – in the sense that ML xAPP is treated no differently from other types of xAPP. + +2. File based deployment: The AI/ML model can be deployed based on the AI/ML model file, which is generally decoupled with the xAPP software version, and can be enabled and updated via the xAPP file configuration. For this scenario, a ML model catalog and an inference platform/engine are usually required for the ML model inference host (i.e., Near-RT RIC). The Near-RT RIC may have an unified inference platform/engine, which can help to accelerate the inference efficiency (exploiting native ML capabilities of the platform) and enable greater customization but which requires the ML model file format to be supported by the inference platform. + +Figure 7-1 illustrates an example of image based vs file based ML model deployments. + +![Figure 7-1: Examples of image based and file based ML model deployment. The diagram shows two architectures for Near-RT RIC. The left architecture, 'Image based deployment', shows a stack: service portal, Kubernetes, container runtime (containing xAPP and ML xAPP), Docker Engine, and Near-RT RIC. An arrow labeled 'ML Docker Image' points to this stack. The right architecture, 'File based deployment', shows a stack: service portal, Model Transformation & Loading, Inference runtime (containing ML model pipeline and Inference Engine), ML service gateway, and Near-RT RIC. An arrow labeled 'ML model file' points to this stack. A service bus connects the two architectures, with xAPP and runtime components on the right.](acbb9a7262044b44f476fd78e01a9c9e_img.jpg) + +Figure 7-1: Examples of image based and file based ML model deployment. The diagram shows two architectures for Near-RT RIC. The left architecture, 'Image based deployment', shows a stack: service portal, Kubernetes, container runtime (containing xAPP and ML xAPP), Docker Engine, and Near-RT RIC. An arrow labeled 'ML Docker Image' points to this stack. The right architecture, 'File based deployment', shows a stack: service portal, Model Transformation & Loading, Inference runtime (containing ML model pipeline and Inference Engine), ML service gateway, and Near-RT RIC. An arrow labeled 'ML model file' points to this stack. A service bus connects the two architectures, with xAPP and runtime components on the right. + +**Figure 7-1 - Examples of image based and file based ML model deployment** + +Notes: The above figure only shows examples of how Near-RT RIC works under the image based ML model deployment and the file based ML model deployment. It may have different Near-RT RIC internal implementation. + +Table 3 compares the Pros and Cons of the two approaches. + +**Table 3 - Pros and Cons of the image based and file based ML model deployment** + +| Options | Pros | Cons | +|---------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| Opt1: Image Based ML model deployment |

    Faster and flexible deployment.

    Less requirements on the ML model inference host, i.e., Near-RT RIC, except for support of container runtime env.

    |

    The inference efficiency depends on the container capability.

    | +| Opt2: File Based ML model deployment |

    Better customization and efficiency by exploiting the on-device model optimization and update capabilities.

    Potential use of standard file formats for ML models.

    |

    Additional function requirement for the ML model inference host.

    Requires the matching of the ML model format and the inference engine.

    | + +# Annex A (Informative) + +## A.1 Discussion on A1/O1 clarification + +The following table tries to summarize WG2 involved information exchange over O1 and A1 interface based on the UCR doc and AI/ML workflow discussion. + +**Table 4 - A1 vs O1 information exchange** + +| Information | Interface | Management Services | Remarks | +|----------------------------------------|-----------|-------------------------|---------------------------------------------------------------------------------------------| +| Policy | A1 | | | +| Enrichment information | A1 | | | +| Policy feedback | A1 | | Feedback for model state | +| Non-RT RIC performance data collection | O1 | Performance measurement | SMO internal interface to access O1 data | +| Non-RT RIC Fault data collection | O1 | Fault measurement | SMO internal interface to access O1 data | +| Network parameter configuration | O1 | Provisioning management | O1-CM | +| AI/ML model deployment | O1 | Software management | | +| AI/ML model update | O1 | Software management | Containerized, same for xApp update/revision control as per OAM | +| AI/ML model performance monitoring | O1 | | Enhancement is needed. How to model the AI/ML in the information model needs further study. | + +## A.2 Examples of ML model capabilities/descriptors + +- ML capabilities may include performance aspects of the target network function (e.g. CPU, memory, etc.), support for ML engines and supported libraries. +- These capabilities need to be matched against an ML model descriptor to decide whether a model can be deployed in the target network function. + +![Two JSON schema diagrams side-by-side. The left diagram shows a general ML model descriptor schema with fields like name, version, properties, runtime, and dependencies. The right diagram shows a specific example for a face_privacy_detection use case, including runtime details like name, encoding, version, and a list of dependencies (pip, conda) with their respective package names and versions.](c91e19aa227adcdbd86bdbc79e13e6f3_img.jpg) + +The image displays two JSON schema diagrams. The left diagram is a general ML model descriptor schema, and the right diagram is a specific example for a face\_privacy\_detection use case. + +**Left Diagram (General Schema):** + +- Schema:** "http://json-schema.org/draft-04/schema#" + - self:** + - name:** "acumos.schema.model" + - version:** "0.5.0" + - properties:** + - required:** (array) + - definitions:** + - Runtime:** + - type:** "object" + - properties:** + - name:** (string) + - version:** (string) + - encoding:** (string) + - dependencies:** (array) + - oneOf:** (array) + - 0:** \$ref: "#/definitions/PythonDependencies" + - 1:** (array) + - 2:** (array) + +**Right Diagram (Specific Example):** + +- Schema:** "acumos.schema.model 0.4.0" +- runtime:** + - name:** "python" + - encoding:** "protobuf" + - version:** "3.6.6" + - dependencies:** (array) + - pip:** + - indexes:** (array) + - requirements:** (array) + - 0:** + - name:** "dill" + - version:** "0.2.7.1" + - 1:** + - name:** "pandas" + - version:** "0.23.4" + - 2:** + - name:** "opencv-python" + - version:** "3.3.0.10" + - 3:** + - name:** "scikit-learn" + - version:** "0.20.0" + - 4:** + - name:** "numpy" + - version:** "1.15.3" + - 5:** + - name:** "acumos" + - version:** "0.7.0" +- conda:** + - name:** "face\_privacy\_detect\_AI" + +- methods:** (array) +- detect:** + - input:** "Image" + - output:** "RegionDetectionSet" + - description:** "Transform from image or detection and return score or image" + +Two JSON schema diagrams side-by-side. The left diagram shows a general ML model descriptor schema with fields like name, version, properties, runtime, and dependencies. The right diagram shows a specific example for a face\_privacy\_detection use case, including runtime details like name, encoding, version, and a list of dependencies (pip, conda) with their respective package names and versions. + +Figure A.2 1 - Example ML model descriptor schema + +Figure A.2 1 エラー! 参照元が見つかりません。 provides an example schema for ML models and an illustration for a face\_privacy\_detection use case. It shows the input/output mapping and a set of ML model runtime dependencies. + +# Annex N (Informative) + +## N.1 Appendix X + +The following figure shows the comparison of the inference performance of the original TensorFlow models and the compiled models running in different inference framework. (The model compilation and optimization, and inference engine are provided by Adlik [\[7\]](#).) + +| Model | Inference Performance improved after Adlik Optimized | | +|----------|------------------------------------------------------|------| +| | CPU | GPU | +| ResNet50 | 397% | 422% | +| VGG16 | 360% | 214% | + +Figure N.1 1 - Comparison of inference performance in different inference framework with Adlik toolkit + +Inference performance is measured by pcs/s (processed pictures per second). + +Test bed : Batch size: 64; CPU: 2; Memory: 8G; GPU: 1\*NVIDIA P100 + +# Annex Z: O-RAN Adopter License Agreement + +# O-RAN ADOPTER LICENSE AGREEMENT + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +### SECTION 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Portion” means only those specific portions of products (hardware, software or combinations thereof) that implement any O-RAN Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or + +Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by implementation of a Final Specification (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate an implementation which complies with a Final Specification without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +### SECTION 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a non-exclusive, non-transferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN Specification + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +### SECTION 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair, Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Portions; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Portion is incorporated that is not itself part of the Compliant Portion; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing license includes the distribution by the Adopter’s distributors and the use by the Adopter’s customers of such licensed Compliant Portions. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under FRAND terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Portions; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Portion is incorporated that is not itself part of the Compliant Portion; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing license includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Portions. + +### SECTION 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of O-RAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +### SECTION 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +### SECTION 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +### SECTION 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. + +O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +### SECTION 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance's sole discretion. O-RAN Alliance may freely assign this Agreement. + +### SECTION 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +### SECTION 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +### SECTION 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without + +1 limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter +2 acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +3 +4 By execution hereof, no form of any partnership, joint venture or other special relationship is created between +5 Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set +6 forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN +7 Alliance or its Members, Contributors or Academic Contributors. + +8 +9 In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be +10 null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be +11 deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this +12 Agreement will remain in full force and effect. + +13 +14 Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any +15 of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise +16 by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or third party +17 beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other instance; +18 rather the same shall be and remain in full force and effect. \ No newline at end of file diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/0637d3b96d4fa3f289ad92c7492070de_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/0637d3b96d4fa3f289ad92c7492070de_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c01361dcc814bc9850d87816d7bf8bb6295e2eb3 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/0637d3b96d4fa3f289ad92c7492070de_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8251852e3f749a81a5b7077ca8f3233a75c1b762ba17aab31cb601e6dec17585 +size 146797 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2fd5eaeff22262dc085e14adfdb0ad2472ac9dc2 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd2727019ae96e80efda4964e1a871737c2c73277a978726969f55d0e5275c2f +size 4536 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/0dd4f15e2754a6a0c0c6431c47fe608e_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/0dd4f15e2754a6a0c0c6431c47fe608e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..576e8946de286dcf9e01c093e38e528d8cdfc64f --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/0dd4f15e2754a6a0c0c6431c47fe608e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d339a30cc8b173630ddc09fbc917ca2c34933622b66aab5e9d22246f095edb9e +size 151665 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/10d2072a16f946b173f0f17245646e56_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/10d2072a16f946b173f0f17245646e56_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd2c0413c659c4f5ab1e5aaf3029d153fb9cea0e --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/10d2072a16f946b173f0f17245646e56_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9f6d5946fd04b1fc9002b34798a229d48bba6da81418c13d74d20ffaaeb3a6a +size 212959 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/1ff1acedf67b83f08dfb68ced8fe0a24_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/1ff1acedf67b83f08dfb68ced8fe0a24_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..13275b1b76e03935e812baa288780909bec26baf --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/1ff1acedf67b83f08dfb68ced8fe0a24_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ef54e2ecd6ebaa89efb6e6fa6224942a55ad4f01d50a044bb90dffbe78a68461 +size 165926 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/20a42da32eef641726c0d6215295102d_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/20a42da32eef641726c0d6215295102d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..42184a5a9d18e1462afc353a8a1a051814e1a36a --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/20a42da32eef641726c0d6215295102d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:45af47eb9c7079e7caeed001163d66132eebc3e6bb2d5a48f02900397611b711 +size 110999 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/249285c18126b9268169723453511912_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/249285c18126b9268169723453511912_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..76bbb56d2f15500540c39f4c59b125588e4fc29b --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/249285c18126b9268169723453511912_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0c611e50b41d7224e5119940abe04cd959b86bff96435f07906ad58b961b43cb +size 4601 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/342ac84634b673b0a0234f1f312cfd61_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/342ac84634b673b0a0234f1f312cfd61_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..770af59d25f2cab09719c693cc72847a5149d44c --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/342ac84634b673b0a0234f1f312cfd61_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:29b280a4892a3d6e2110365f242c953f4e1f12e16ec214c9724e7d710c72efdd +size 158687 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/4c1d36e7e9b1afb90721dcc9fb45a557_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/4c1d36e7e9b1afb90721dcc9fb45a557_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7e06a4eb2614b812839be2c0776fed3825941a30 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/4c1d36e7e9b1afb90721dcc9fb45a557_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:739384ee644447fdd633a2d7ca2445f7b39697efbb41ccd25e264b27463bddea +size 237396 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/4cbfebc98185156dbae2b61dc16c051c_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/4cbfebc98185156dbae2b61dc16c051c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0aa62744a9dd3928800c51d0bd99f27387466757 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/4cbfebc98185156dbae2b61dc16c051c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e5cf917407b66de4e0ad2e8bf9b9590171a94326918468759a1ff6220a61eb5c +size 130274 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/53a35ae4b6173e48c9fb0b085b6b0f69_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/53a35ae4b6173e48c9fb0b085b6b0f69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1414eacb55dd901864721d2ba930f5ce5a9a5b0b --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/53a35ae4b6173e48c9fb0b085b6b0f69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ef4438d8d82c5896304496679c79ddbbc2571aaa44c128c301e393a65d6ce145 +size 164105 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/5f738372920d8e51e68c568347d85297_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/5f738372920d8e51e68c568347d85297_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c91c0cc268ee6ca1547acca88e961a4e785006ef --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/5f738372920d8e51e68c568347d85297_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b7137bb8ebd3a85e772cb2ab80735f57f6ae6a56e7cacf955be08fdece241dd +size 4537 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/8fff37ade622ba5534e81b889a1cfdc5_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/8fff37ade622ba5534e81b889a1cfdc5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3abcb2130cbc1f766073f741a3db6cadf5a97a34 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/8fff37ade622ba5534e81b889a1cfdc5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:14554d1013ad3fec5b821550aa0449a207a83e2b0ce260b91bf2cb877d43b85b +size 103813 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/9e3335c1da87b3270486f8690dcbcfed_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/9e3335c1da87b3270486f8690dcbcfed_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0b848423ffa5ffaf428ad7159a5db7811d1dc699 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/9e3335c1da87b3270486f8690dcbcfed_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:14ac2267048e8e98e7633c3869935e74b7d9f58dc586dfbb904647de5fd10cfa +size 112202 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/a4cd4074d265ca65a54ff2a58c6c379a_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/a4cd4074d265ca65a54ff2a58c6c379a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d9e763b3931fd94df46567bffe11d72d0c2f8420 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/a4cd4074d265ca65a54ff2a58c6c379a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c98d9ee1d4a56a96ea4960a29163b640c17100eb6e8e1df6252108793d052b5f +size 167719 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/bc6d103298fce2813b1c023dc1e3a5e9_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/bc6d103298fce2813b1c023dc1e3a5e9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cba6b28c5131a1cafad18167ace8a1ff754da1a3 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/bc6d103298fce2813b1c023dc1e3a5e9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c557466c2a21be7c1a8b94cfd2f7af4da3cee2d1a5826b55ba139ddce8f4987b +size 107258 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/c17df69740c9a43f50eb17a847420477_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/c17df69740c9a43f50eb17a847420477_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..af4cd8ae49d2017a450652dd9a54186c9291be30 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/c17df69740c9a43f50eb17a847420477_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b15cc560ea485dcfd0446441dca6a6e5b675356a42cb89bd695dedfa5135546 +size 165596 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/c8a411a4bae96a0905d6730776dab076_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/c8a411a4bae96a0905d6730776dab076_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3a6b97ac2d5fce3d7cc16b2bd1caea88086c6b34 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/c8a411a4bae96a0905d6730776dab076_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b0aac59a538f8d6f897cc9f6d1c467c19a520b14f83c088b82c05914f127a7b +size 148205 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/cf858b014f14b4d4fb83458546cd1475_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/cf858b014f14b4d4fb83458546cd1475_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..18b56350a34745d8150563aeadae0c76a1e43151 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/cf858b014f14b4d4fb83458546cd1475_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e5edfb1ae00e21546b7cc6a6a828481b0433158a6d265fa8a90d96000fc953a3 +size 144926 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7423b16589e846f2b16ec9a44a377d2efd9a9090 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b000e2a5c716ba0590040bc3dc3321438d999e8b057249129751dff05131f8c +size 4564 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/f3ef1396f2da5b9115324fda59e116fd_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/f3ef1396f2da5b9115324fda59e116fd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..28dafc030f012591d6565d1bd3bf040d0f8cda0e --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/f3ef1396f2da5b9115324fda59e116fd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5e1a5b96a69b65301c23c0563b13bb0ef19f74f68a399171d62040639636977f +size 129843 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/f6ecf395a54b348ab80ec0c6f6ebbfec_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/f6ecf395a54b348ab80ec0c6f6ebbfec_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0f922d15e4c931fcc3542fb62f25a98035dfb69f --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/f6ecf395a54b348ab80ec0c6f6ebbfec_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7ad69aebe1cea8385ffbbd9ba6119251f6887764cf253d34554f701096aa557f +size 207851 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/fb4ad596448e423fe3ace53dc652a811_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/fb4ad596448e423fe3ace53dc652a811_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..07bd3b4ded27d745d35f7f0a1f8d000cf489ecb7 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/fb4ad596448e423fe3ace53dc652a811_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fc0ab26a08bb6704761236e5c3b98ca1d6aad86414b042e38fe1c4788d7548be +size 64930 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/raw.md b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..3696c8cc774f511054f4171f99508665c26dbacf --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00/raw.md @@ -0,0 +1,2740 @@ + + +# --- Non-RT RIC: Architecture + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|----------------------------------------------------------|----| +| Foreword..... | 4 | +| Modal verbs terminology ..... | 4 | +| 1 Scope..... | 5 | +| 2 References ..... | 5 | +| 2.1 Normative references ..... | 5 | +| 2.2 Informative references ..... | 5 | +| 3 Definition of terms, symbols and abbreviations ..... | 6 | +| 3.1 Terms ..... | 6 | +| 3.2 Symbols..... | 6 | +| 3.3 Abbreviations..... | 6 | +| 4 Overview ..... | 7 | +| 4.1 Non-RT RIC in O-RAN overall architecture..... | 7 | +| 4.2 Void..... | 7 | +| 5 Requirements..... | 7 | +| 5.1 Requirements for the Non-RT RIC framework ..... | 7 | +| 5.2 Requirements for R1 ..... | 10 | +| 5.3 Requirements for rApps..... | 10 | +| 6 Non-RT RIC Architecture..... | 10 | +| 6.1 General..... | 10 | +| 6.2 R1 interface..... | 12 | +| 7 R1 Service Definitions ..... | 12 | +| 7.1 General description ..... | 12 | +| 7.2 Service management and exposure services ..... | 13 | +| 7.3 Data management and exposure services ..... | 13 | +| 7.4 A1-related Services..... | 14 | +| 7.4.1 A1 policy management services..... | 14 | +| 7.4.2 A1 enrichment information related services ..... | 15 | +| 7.5 RAN OAM-related Services ..... | 15 | +| 7.6 O2-related services..... | 16 | +| 7.7 AI/ML workflow services..... | 16 | +| 7.8 rApp management services ..... | 17 | +| 7.9 TE&IV-related services ..... | 17 | +| 8 Non-RT RIC Function Definitions..... | 17 | +| 8.1 General description ..... | 17 | +| 8.2 Service management and exposure functions ..... | 18 | +| 8.2.1 Service registration and discovery functions ..... | 18 | +| 8.2.2 Authentication and authorisation functions..... | 18 | +| 8.3 Data management and exposure functions ..... | 18 | +| 8.4 A1-related functions..... | 19 | +| 8.4.1 A1 policy functions ..... | 19 | +| 8.4.2 A1 enrichment information functions ..... | 20 | +| 8.5 RAN OAM-related functions..... | 20 | +| 8.6 O2-related functions..... | 20 | +| 8.7 AI/ML workflow functions..... | 21 | +| 9 External Interfaces..... | 21 | +| 9.1 A1 Interface ..... | 21 | +| 9.2 Void..... | 21 | +| 10 Procedures ..... | 21 | +| 10.1 Data management and exposure procedures..... | 21 | +| 10.1.0 Overview ..... | 21 | + +| | | | +|--------------------------------------------------|------------------------------------------------------------------------------|-----------| +| 10.1.1 | Subscribe data procedures in data consumption and collection ..... | 22 | +| 10.1.2 | Request data procedure in data consumption and data collection..... | 27 | +| 10.1.3 | O1 related data collection procedures based on data subscription..... | 29 | +| 10.1.4 | O2 related data collection procedures based on data subscription..... | 31 | +| 10.1.5 | Data offer procedures ..... | 33 | +| 10.2 | A1-related procedures ..... | 36 | +| 10.2.1 | EI results collection from rApps ..... | 36 | +| 10.2.2 | rApp creating a policy with a Near-RT RIC identifier..... | 39 | +| 10.3 | RAN OAM-related procedures ..... | 40 | +| 10.3.1 | Alarm query procedure..... | 40 | +| 10.3.2 | Change alarm acknowledgement state procedure ..... | 41 | +| 10.3.3 | Read configuration data procedure ..... | 43 | +| 10.3.4 | Write configuration changes procedure ..... | 45 | +| 10.4 | AI/ML workflow procedures ..... | 47 | +| 10.4.1 | rApps register, discover AI/ML models, and subscribe to models changes ..... | 47 | +| 10.4.2 | AI/ML training procedures..... | 50 | +| 10.4.3 | AI/ML model storage and retrieval procedures ..... | 57 | +| Annex (informative): Change History ..... | | 59 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG2 of the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the technical specification for the Non-RT RIC (RAN Intelligent Controller) architecture. This document collects requirements on the Non-RT RIC framework, hosted applications, and services of the R1 interface. This document specifies Non-RT RIC framework functionalities and services exposed to the applications. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] Void. +- [2] O-RAN TS: “O-RAN Architecture Description” (“OAD”). +- [3] O-RAN TS: “Non-RT RIC and A1/R1 interface: Use Case and Requirements” (“WG2 UCR”). +- [4] O-RAN TS: “A1 interface: General Aspects and Principles” (“A1GAP”). +- [5] O-RAN TS: “A1 interface: Application Protocol” (“A1AP”). +- [6] O-RAN TS: “A1 interface: Transport Protocol” (“A1TP”). +- [7] O-RAN TS: “A1 interface: Type Definitions” (“A1TD”). +- [8] O-RAN TS: “O-RAN Operations and Maintenance Architecture” (“OAM Arch”). +- [9] O-RAN TS: “R1 interface: General Aspects and Principles” (“R1GAP”). +- [10] O-RAN TS: “Security Requirements and Controls Specification” (“SRS”). +- [11] O-RAN TS: “O-RAN Operations and Maintenance Interface Specification” (“O1 interface”). +- [12] O-RAN TS: “Topology Exposure and Inventory Management Services Use Cases and Requirement Specification” (“TE&IV”). +- [13] O-RAN TS: “O2 Interface General Aspects and Principles” (“O2GAP”). + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regards to a particular subject area. + +- [i.1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [i.1] and the following apply. + +A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [i.1]. + +**Functions anchored inside the Non-RT RIC framework:** Logical functions in the SMO framework that are part of the Non-RT RIC framework. + +**Functions anchored outside the Non-RT RIC framework:** Logical functions in the SMO framework that are not part of the Non-RT RIC framework. + +**Non-RT RIC (O-RAN Non-Real-Time RAN Intelligent Controller):** A logical function within SMO that enables non-real-time control and optimization of RAN elements and resources, AI/ML workflow including model training and updates, and policy-based guidance of applications/features in Near-RT RIC. + +**Near-RT RIC (O-RAN Near-Real-Time RAN Intelligent Controller):** A logical function that enables near-real-time control and optimization of RAN elements and resources via fine-grained data collection and actions over E2 interface. + +**Non-anchored functions:** Logical functions in the SMO framework that may or may not be part of the Non-RT RIC framework. + +**R1 Data Producer:** An entity capable of producing data which can be consumed by other entities and of registering for discovery information about the types of these data in the context of the data management and exposure service. + +**R1 Data Consumer:** An entity capable of consuming data originating from other entities in the context of the data management and exposure service. + +**R1 Service Producer:** An entity capable of producing an R1 service which can be consumed by other entities. + +**R1 Service Consumer:** An entity capable of consuming an R1 service produced by other entities. + +**AI/ML model:** An algorithm that applies AI/ML techniques to produce model output data based on model input data. + +**AI/ML model training:** A process to train an AI/ML model by learning the input/output relationship in a data driven manner and obtain a trained AI/ML model that can be used for inference. + +**AI/ML model parameter:** Internal parameter of an AI/ML model that is learnt during AI/ML model training. + +**Hyperparameter:** A parameter whose value controls the learning process and the topology of an AI/ML model and which influences the quality of the learning process. + +**AI/ML model inference:** A process of using an AI/ML model to produce model output data based on model input data. + +**AI/ML model performance monitoring:** A procedure that monitors the inference performance of a deployed AI/ML model. + +**rApp instance:** An individual occurrence of a Non-RT RIC application running in the Non-RT RIC runtime environment. + +**rApp instance identifier:** A unique identifier for each rApp instance, assigned by the SMO/Non-RT RIC framework during rApp registration. + +**DME type:** Data type managed and exposed by the DME services and identified by a DME type identifier. + +## 3.2 Symbols + +Void. + +## 3.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply. + +| | | +|-------------|---------------------------------------------------------| +| API | Application Programming Interface | +| AI | Artificial Intelligence | +| CM | Configuration Management | +| DME | Data Management and Exposure | +| DMS | Deployment Management Services | +| EI | Enrichment Information | +| FCAPS | Fault, Configuration, Accounting, Performance, Security | +| FM | Fault Management | +| FOCOM | Federated O-Cloud Orchestration and Management | +| HTTP | Hypertext Transfer Protocol | +| IMS | Infrastructure Management Services | +| ML | Machine Learning | +| MOI | Managed Object Instance | +| Near-RT RIC | Near-Real-Time RAN Intelligent Controller | +| NFO | Network Function Orchestration | +| Non-RT RIC | Non-Real-Time RAN Intelligent Controller | +| OAM | Operation, Administration and Maintenance | +| O-RU | O-RAN Radio Unit | +| PM | Performance Management | +| QoS | Quality of Service | +| rAppId | rApp instance Identifier | +| RAN | Radio Access Network | +| SME | Service Management and Exposure | +| SMO | Service Management and Orchestration | +| TE&IV | Topology Exposure and Inventory Management | +| UE | User Equipment | +| URI | Uniform Resource Identifier | + +# 4 Overview + +## 4.1 Non-RT RIC in O-RAN overall architecture + +Non-Real Time RAN Intelligent Controller (Non-RT RIC) is the functionality internal to the Service Management and Orchestration (SMO) framework in O-RAN overall architecture, as shown in O-RAN OAD[2], Figure 4.1-2. + +- Non-RT RIC represents a subset of functionality of the SMO framework. +- Non-RT RIC supports intelligent RAN operation and optimization. +- Non-RT RIC logically terminates the A1 interface, and it provides policy-based guidance and enrichment information to the Near-RT RICs. AI/ML model management on the A1 interface is not specified in the present document. +- Non-RT RIC can access other SMO framework functionalities, for example influencing what is carried across the O1, open fronthaul M-plane and O2 interface. + +## 4.2 Void + +# 5 Requirements + +## 5.1 Requirements for the Non-RT RIC framework + +| | | +|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-NRTFWK-FUN1] | The Non-RT RIC framework shall support functionality to register services along with their Service Producers in the Non-RT RIC and SMO. | +|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-NRTFWK-FUN2] | The Non-RT RIC framework shall support functionality to allow Service Consumers to discover services. | +| [REQ-NRTFWK-FUN3] | The Non-RT RIC framework shall support functionality to allow Service Consumers to subscribe/unsubscribe notifications about newly registered/updated/deregistered services. | +| [REQ-NRTFWK-FUN4] | The Non-RT RIC framework shall support functionality to notify subscribed Service Consumers about newly registered/updated/deregistered services. | +| [REQ-NRTFWK-FUN5] | The Non-RT RIC framework shall support functionality to authenticate Service Consumers, if such functionality is not provided by the SMO framework. | +| [REQ-NRTFWK-FUN6] | The Non-RT RIC framework shall support functionality to authorize Service Consumers to access services, if such functionality is not provided by the SMO framework. | +| [REQ-NRTFWK-FUN7] | The Non-RT RIC framework shall support functionality to send messages to and receive messages from the Near-RT RIC via the A1 interface. | +| [REQ-NRTFWK-FUN8] | The Non-RT RIC framework shall support functionality to allow Data Consumers (including rApps) to discover available DME types, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN9] | The Non-RT RIC framework shall support functionality to allow Data Producers (including rApps) to register their DME types production capabilities, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN10] | The Non-RT RIC framework shall support functionality to allow Data Consumers (including rApps) to subscribe/request instances of registered DME types for consumption, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN10a] | The Non-RT RIC framework shall support functionality to allow Data Producers (including rApps) to offer instances of registered DME types for collection and storage, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN11] | The Non-RT RIC framework shall support functionality to train AI/ML models, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN12] | The Non-RT RIC framework shall support functionality to allow Service Consumers to store and retrieve trained AI/ML models, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN13] | The Non-RT RIC framework shall support functionality to monitor the performance for deployed AI/ML models in runtime, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN14] | The Non-RT RIC framework may support functionality to collect external enrichment information from external enrichment information sources. | + +| | | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-NRTFWK-FUN15] | The Non-RT RIC framework may support functionality to retrieve trained AI/ML models (and metadata) from external AI/ML service providers. | +| [REQ-NRTFWK-FUN16] | The Non-RT RIC framework may support functionality to allow external sources to inject RAN intents, suspend/resume/check rApps, and configure/check/initiate/suspend/resume/terminate AI/ML training processes. | +| [REQ-NRTFWK-FUN17] | The Non-RT RIC framework shall support functionality to consolidate the alarm information from multiple managed entities, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN18] | The Non-RT RIC framework shall support functionality to store alarm acknowledgement state for alarms originating from managed entities that do not support alarm acknowledgement state change, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN19] | The Non-RT RIC framework may have the capability to identify the potentially applicable Near-RT RIC(s) for A1 policy creation if the Near-RT RIC identifier is absent in the create A1 policy request received from the rApp. | +| NOTE: Selection of potentially applicable Near-RT RIC(s) can be based, e.g., on the content of the received create A1 policy request or on configuration. | | +| [REQ-NRTFWK-FUN20] | The Non-RT RIC framework shall support the functionality to collect trace data, from multiple managed entities, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN21] | The Non-RT RIC framework shall support the functionality to collect analytical data from the Near-RT RIC, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN22] | The Non-RT RIC framework shall support functionality to allow Data Consumers (including rApps) to consume Deployment Telemetry metrics collected by the O2-related functions. | +| [REQ-NRTFWK-FUN23] | The Non-RT RIC framework shall support functionality to allow Data Consumers (including rApps) to consume Infrastructure Telemetry metrics collected by the O2-related functions. | +| [REQ-NRTFWK-FUN24] | The Non-RT RIC framework shall support functionality that allows managing the configuration of an rApp, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN25] | The Non-RT RIC framework shall support functionality that allows obtaining, from an rApp, information about that rApp's performance, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN26] | The Non-RT RIC framework shall support functionality that allows obtaining, from an rApp, fault information related to that rApp, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN27] | The Non-RT RIC framework shall support functionality that allows obtaining, from an rApp, logging information reported by the rApp, if such functionality is not supported in the SMO framework. | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-NRTFWK-FUN28] | The Non-RT RIC framework shall support functionality to store log information received from rApps, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN29] | The Non-RT RIC framework shall support functionality that allows an rApp to obtain, over the R1 interface, TE&IV information based on the requirements defined in O-RAN TE&IV [12], if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN30] | The Non-RT RIC framework shall support functionality that allows registration and deregistration of an AI/ML model, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN31] | The Non-RT RIC framework shall support functionality that allows the discovery of registered AI/ML models, if such functionality is not supported in the SMO framework. | +| [REQ-NRTFWK-FUN32] | The Non-RT RIC framework shall support functionality that allows the deployment of an AI/ML model, if such functionality is not supported in the SMO framework. | + +In addition, the security requirements for the Non-RT RIC specified in O-RAN SRS [10], clause 5.1.2 apply. + +## 5.2 Requirements for R1 + +O-RAN WG2 UCR [3] specifies R1 interface functional requirements. + +## 5.3 Requirements for rApps + +The security requirements for rApps specified in O-RAN SRS [10], clause 5.1.2 apply. + +# 6 Non-RT RIC Architecture + +## 6.1 General + +Non-RT RIC is comprised of: + +- Non-RT RIC Framework – Functionality internal to the SMO Framework that: + - Logically terminates the A1 interface to the Near-RT RIC. + - Exposes set of R1 services to Non-RT RIC Applications (rApps). +- Non-RT RIC Applications (rApps) – Applications that leverage the functionalities available in the SMO/Non-RT RIC framework to provide value added services related to RAN operation and optimization. The scope of rApps includes, but is not limited to, RAN configuration management, data analytics, producing training services, generating AI policies, and providing enrichment information. + +The following figure depicts the reference architecture of the Non-RT RIC as part of the SMO framework. + +![Figure 6.1-1: Non-RT RIC reference architecture diagram. The diagram shows the SMO framework and Non-RT RIC components. The SMO framework includes External EI Sources, External AI/ML services, and External oversight. The Non-RT RIC includes rApp, R1 termination, Service management and exposure functions, rApp management functions, Other Non-RT RIC framework functions, A1-related functions, A1 termination, External terminations, AI/ML workflow functions, Data management and exposure functions, O2-related functions, RAN OAM-related functions, TE&IV related functions, and Other SMO framework functions. The Non-RT RIC framework includes R1 termination, rApp management functions, Other Non-RT RIC framework functions, A1-related functions, A1 termination, External terminations, AI/ML workflow functions, Data management and exposure functions, O2-related functions, RAN OAM-related functions, TE&IV related functions, and Other SMO framework functions. The Non-RT RIC framework is connected to the M-plane, which includes O2, Open FH M-Plane termination, O1, and A1. The M-plane is connected to the O-Cloud, Near-RT RIC, E2 Nodes, and O-RU. The diagram also shows the O-RAN-defined interface and External interface. A legend at the bottom indicates: Function anchored inside the Non-RT RIC framework (solid blue box), Functions anchored outside the Non-RT RIC framework (solid orange box), Non-anchored functions (dashed line box), O-RAN-defined interface (solid line), External interface (dashed line), and Implementation-specific (dotted line).](f3ef1396f2da5b9115324fda59e116fd_img.jpg) + +Figure 6.1-1: Non-RT RIC reference architecture diagram. The diagram shows the SMO framework and Non-RT RIC components. The SMO framework includes External EI Sources, External AI/ML services, and External oversight. The Non-RT RIC includes rApp, R1 termination, Service management and exposure functions, rApp management functions, Other Non-RT RIC framework functions, A1-related functions, A1 termination, External terminations, AI/ML workflow functions, Data management and exposure functions, O2-related functions, RAN OAM-related functions, TE&IV related functions, and Other SMO framework functions. The Non-RT RIC framework includes R1 termination, rApp management functions, Other Non-RT RIC framework functions, A1-related functions, A1 termination, External terminations, AI/ML workflow functions, Data management and exposure functions, O2-related functions, RAN OAM-related functions, TE&IV related functions, and Other SMO framework functions. The Non-RT RIC framework is connected to the M-plane, which includes O2, Open FH M-Plane termination, O1, and A1. The M-plane is connected to the O-Cloud, Near-RT RIC, E2 Nodes, and O-RU. The diagram also shows the O-RAN-defined interface and External interface. A legend at the bottom indicates: Function anchored inside the Non-RT RIC framework (solid blue box), Functions anchored outside the Non-RT RIC framework (solid orange box), Non-anchored functions (dashed line box), O-RAN-defined interface (solid line), External interface (dashed line), and Implementation-specific (dotted line). + +**Figure 6.1-1: Non-RT RIC reference architecture** + +There are three categories of logical functions in Non-RT RIC framework and SMO framework: + +- Functions anchored inside the Non-RT RIC framework, which are indicated in solid blue box in figure 6.1-1. +- Functions anchored outside the Non-RT RIC framework, which are indicated in solid orange box in figure 6.1-1. +- Non-anchored functions, which are indicated in dashed line box in figure 6.1-1. + +The categories are defined in clause 3.1. The definitions make no assumption on the mandatory or optional qualifier of the functions being anchored or non-anchored. + +The decomposition of logical functions is not mandatory, and it is up to vendor's implementation. + +NOTE 1: There might be other SMO framework functions or other Non-RT RIC framework functions which may provide additional services exposed via the R1 interface or provide EI for A1 enrichment information services. These are not specified in the present document. + +NOTE 2: Other SMO framework functions may be defined by other O-RAN WGs and the potential impacts on Non-RT RIC architecture are not specified in the present document. + +NOTE 3: Whether the A1-related functions are anchored functions or not is not specified in the present document. + +NOTE 4: Among other functionalities, the Other SMO framework functions also realize OAM functionality related to RAN-specific network slicing. + +NOTE 5: The Topology Exposure and Inventory Management functions are not elaborated in this present document. + +Service management and exposure functions enable (not limited to): service registration, service discovery, service notification, authorization, authentication, communication support, and optional bootstrap and heartbeat services. + +The rApp management functions enable the management of rApps within the context of the SMO/Non-RT RIC framework. Such functions enable (not limited to) the configuration of rApps, providing access to fault and performance related information from rApps, and facilitation of rApp logging functionality. Through the use of R1, rApp management functions + +can provide access to these functionalities in a consistent manner to all rApps. Such consistency is particularly valuable as rApps can be provided independently by different rApp vendors. + +The implementation-specific interfaces, which are indicated by the dashed line in figure 6.1-1, allow the logical functions in SMO/Non-RT RIC framework to communicate with each other by means outside the scope of the present document. + +## 6.2 R1 interface + +The R1 interface is a service-based interface via which the R1 services can be consumed and produced. + +The R1 services are a collection of services produced and consumed by logical functions in the SMO/Non-RT RIC framework or by rApps. + +The invoker of an R1 service is referred to as R1 Service Consumer and the provider of an R1 service is referred to as R1 Service Producer. R1 Service Consumers can be rApps and/or SMO/Non-RT RIC framework functions. Further, R1 Service Producers can be rApps and/or SMO/Non-RT RIC framework functions. + +The R1 termination enables the R1 Service Producers and R1 Service Consumers to exchange messages via the R1 interface. + +An rApp as well as a SMO/Non-RT RIC framework function can produce zero or more R1 Services, likewise an rApp as well as a SMO/Non-RT RIC framework function can consume zero or more R1 Services. + +The R1 termination enables the SMO/Non-RT RIC framework and the rApps to exchange messages via the R1 interface, assuming that the R1 service APIs and the rApps are registered with the R1 service management and exposure functions. + +The communication support provided by the SMO/Non-RT RIC framework allows R1 Service Producers and R1 Service Consumers to exchange messages related to the R1 services. Different deployment options are possible, such as: + +- Plain connectivity that enables the point-to-point exchange of service-related messages between R1 Service Producers and R1 Service Consumers e.g. over HTTP. +- Service meshes that enable the combination of discovery of R1 service API endpoints with the routing of service-related messages between R1 Service Consumers and R1 Service Producers. +- Message buses that enable R1 Service Producers to send service-related messages to zero or more R1 Service Consumers simultaneously. + +# --- 7 R1 Service Definitions + +## 7.1 General description + +A service is a set of capabilities related to each other, offered by a Service Producer to Service Consumer(s) for consumption. The capabilities within a service typically have a common purpose and can be inter-dependent. In order to improve re-usability, the mutual coupling across any two services is usually avoided or minimized. Services are produced by Service Producers and consumed by Service Consumers through service endpoints (typically APIs). The interoperability of Service Producers and Service Consumers is ensured by support of the related service endpoints, but it does not depend on the decomposition of logical functions. Being a Service Producer and/or a Service Consumer is a role of an rApp or of a logical function in the SMO or the Non-RT RIC framework (see clause 6). + +The set of R1 services which can be accessed via the R1 interface includes (but is not limited to): + +- Service management and exposure services, which include service registration and service discovery services, authentication services, authorization services and communication support services. The service management and exposure services support extensibility of the set of R1 services. +- Data management and exposure services, which deliver data created or collected by Data Producers to Data Consumers according to their needs. +- A1-related services, which provide access to functionality related to A1. +- AI/ML workflow services, which provide access to AI and ML workflow. + +- RAN OAM-related services, which provide access to RAN OAM functionality related to the O1 and open fronthaul M-plane interfaces, and to the OAM functionality related to RAN-specific network slicing in the SMO framework. +- O2-related services, which provide access to functionality related to O2. +- rApp management services, which provide functionality for managing rApps. +- TE&IV-related services, which provide access to topology and inventory data. + +NOTE: A part of the services listed above may be used on other O-RAN-defined interfaces as well. + +## 7.2 Service management and exposure services + +The following service management and exposure services are defined: + +- Bootstrap service (optional): It enables an rApp to discover the endpoints of the service management and exposure service. +- Registration of services: It allows to register services which includes storing and maintaining profile about each service. It further allows to deregister services and delete the service profile. +- Discovery of services: It supports service discovery for a Service Consumer to find services based on its selection criteria if it is provided. Further, based on the subscription, it notifies its Service Consumers about the newly registered/updated/deregistered services. +- Heartbeat service (optional): It enables an rApp to maintain its R1 service registration status with the service management and exposure services Producer. +- Authentication: It allows the authentication of a Service Producer and/or a Service Consumer. +- Authorisation: It supports to grant Service Consumers access to registered R1 services and to allow Service Producers to produce R1 services. +- Communication support (optional): It supports interaction of R1 Service Consumers and Producers with each other. + +NOTE: Communication support is not specified in the present document. + +## 7.3 Data management and exposure services + +The following data management and exposure services are defined: + +- Data registration service: Data registration allows Data Producers to communicate information about the DME types that they are able to produce. Data Producers need to be authorized to register DME types. +- Data discovery service: Data discovery allows Data Consumers to discover available DME types in the SMO/Non-RT RIC framework. Data Consumers need to be authorized to discover DME types. +- Data subscription service: Using the subscribe data procedure, it allows Data Consumers to consume data continuously from the SMO/Non-RT RIC framework and it further allows the SMO/Non-RT RIC framework to collect data continuously from Data Producers. +- Data request service: Using the request data procedure, it allows Data Consumers to consume data once from the SMO/Non-RT RIC framework and it further allows the SMO/Non-RT RIC framework to collect data once from Data Producers. +- Data delivery services: These allow to deliver data for consumption from the SMO/Non-RT RIC framework to Data Consumers. They further allow to deliver data for collection from Data Producers to the SMO/Non-RT RIC framework. +- Data offer service: It allows a Data Producer to trigger the collection of a data instance by the SMO/Non-RT RIC framework from this Data Producer. + +- Data processing services (optional): These allow Service Consumers to access data processing in the SMO/Non-RT RIC framework. + +NOTE: Data processing services are not specified in the present document. + +Data Producers (e.g., rApps) communicate information about the DME types that they produce in data registration. Data Producers can communicate constraints related to the authorization of the Data Consumers to discover registered DME types and access produced data. Data Producers communicate information about how the data are collected by the SMO/Non-RT RIC framework (e.g., collection periodicity, event-trigger conditions, push or pull, etc.). + +Data Consumers (e.g., rApps) communicate information about the DME types that they want to discover. Data Consumers subscribe/request data from the SMO/Non-RT RIC framework for consumption with specific DME type, periodicity, and delivery (or reporting) method, scope, etc. The delivery (or reporting) method contains information about how the subscribed/requested data are delivered from the SMO/Non-RT RIC framework (e.g., delivery periodicity, event-trigger conditions, push or pull, etc.). + +A Data Producer that intends to trigger the collection of a data instance that it produces defines a data offer by providing to the SMO/Non-RT RIC framework information about the data instance it intends to produce. The information about the data offer includes the properties of the data instance and the supported delivery services. The collection of the data instance starts when the data offer creation has been confirmed by the SMO/Non-RT RIC framework. + +SMO/Non-RT RIC framework collects data produced by Data Producers. SMO/Non-RT RIC framework delivers data to Data Consumers for consumption. SMO/Non-RT RIC framework stores collected data. If the collection of the data was triggered by a data subscription or data request, data storage is optional. SMO/Non-RT RIC framework can optionally process collected and/or stored data (e.g., quantization, normalization, labelling, correlation, etc.). + +## 7.4 A1-related Services + +### 7.4.1 A1 policy management services + +A1 policy management services provided by the SMO/Non-RT RIC framework enable: + +- Discovery of supported A1 policy types. + - rApp queries supported A1 policy types. + - rApp subscribes/unsubscribes notification for changes of supported A1 policy types. SMO/Non-RT RIC framework notifies the subscribed events (e.g., new policy types are added into the supporting list, existing policy types are removed, etc.). +- Creating, updating, querying, and deleting A1 policies. + - rApp creates A1 policies in the SMO/Non-RT RIC framework. SMO/Non-RT RIC framework assigns unique policy identifiers for created A1 policies. + - rApp updates A1 policies created by itself using assigned policy identifiers. + - rApp queries A1 policies in the SMO/Non-RT RIC framework. + - rApp queries A1 policies applied to a given scope (e.g., a UE, a group of UEs, a slice, a QoS flow, a cell, a Near-RT RIC, a policy type, etc.). SMO/Non-RT RIC framework returns queried A1 policies along with assigned policy identifiers. + - rApp queries A1 policies using policy identifiers, if identifiers are known to the rApp. + - rApp can query A1 policies created by itself. + - rApp can query A1 policies created by other rApp with SMO/Non-RT RIC framework's authorization. + - rApp deletes A1 policies created by itself using assigned policy identifiers. +- Querying enforcement status of A1 policies. + +- rApp queries enforcement status of A1 policies using policy identifiers, if identifiers are known to the rApp. +- rApp can query enforcement status of A1 policies created by itself. +- rApp can query enforcement status of A1 policies created by other rApp with SMO/Non-RT RIC framework's authorization. +- Subscription to event notifications related to A1 policies. + - rApp subscribes/unsubscribes notifications for the creation, modification, and deletion of A1 policies created by other rApps. SMO/Non-RT RIC framework notifies rApp of the subscribed events (e.g., a new A1 policy is created, an A1 policy is updated, an A1 policy is removed, etc.), if the rApp is authorized by the SMO/Non-RT RIC framework to receive notifications related to A1 policies created by other rApps. + - Subscription request can be based on a given scope to which A1 policies are applied (e.g., a UE, a group of UEs, a slice, a QoS flow, a cell, a Near-RT RIC, a policy type, etc.). + - Subscription request for A1 policy modification and deletion can be based on policy identifiers, if policy identifiers are known to the rApp. + - rApp subscribes/unsubscribes notifications for changes in enforcement status of A1 policies. SMO/Non-RT RIC framework notifies rApp of the subscribed events. If the subscription request applies to the A1 policies created by other rApps, rApp needs authorization from the SMO/Non-RT RIC framework to receive notifications for enforcement status changes of A1 policies created by other rApps. + - Subscription request can be based on a given scope to which A1 policies are applied (e.g., a UE, a group of UEs, a slice, a QoS flow, a cell, a Near-RT RIC, a policy type, etc.). + - Subscription request can be based on policy identifiers, if identifiers are known to the rApp. + +### 7.4.2 A1 enrichment information related services + +A1 enrichment information related services produced by the SMO/Non-RT RIC framework enable: + +- Registration/deregistration of EI types. + - rApp registers EI types of which data it can produce as the source for the EI job results delivered over the A1 interface. + - rApp deregisters EI types it has registered previously. + +NOTE: EI types cannot per definition, see O-RAN A1AP [5], be updated. If a type definition is modified, the rApp needs to register a new EI type and may deregister the previous EI type. + +## 7.5 RAN OAM-related Services + +RAN OAM-related services produced by the SMO/Non-RT RIC framework enable rApps: + +- To obtain information about alarms related to the network elements. +- To obtain performance information related to the network elements, including but not limited to information related to network slicing. +- To obtain the current configuration of the network elements, including but not limited to information related to network slicing. +- To provision changes to the configuration of the network elements, including but not limited to information related to network slicing. +- To obtain trace information related to the network. +- To obtain additional information related to the network elements, including but not limited to information related to network slicing. + +Here, the network elements refer to the E2 nodes, O-RU and the Near-RT RIC. The RAN OAM-related services provide access to OAM functionality for (i) the E2 nodes and the Near-RT RIC via the O1 interface, (ii) the O-RUs via the open fronthaul M-plane interface, and (iii) RAN-specific network slicing in the SMO framework. + +## 7.6 O2-related services + +O2-related services produced by the SMO/Non-RT RIC framework enable rApps: + +- To obtain information related to O-Cloud infrastructure management services such as, + - Infrastructure inventory. + - Infrastructure monitoring. + - Infrastructure provisioning. + - Infrastructure lifecycle management. + - Infrastructure software management. +- To obtain information related to O-Cloud deployment management services such as, + - Deployment inventory. + - Deployment monitoring. + - Deployment lifecycle management. +- To provision changes of the configuration of the O-Cloud. +- To obtain additional information related to the O-Cloud. + +NOTE: Details about O-Cloud deployment management services, provisioning of configuration changes and additional related information are not specified in the present document. + +## 7.7 AI/ML workflow services + +The following AI/ML workflow services are defined: + +- AI/ML training services: These services allow an AI/ML training service Consumer to request training of an AI/ML model by specifying the training requirements (e.g. required data, model, validation criteria, etc). AI/ML training services can be produced by the SMO/Non-RT RIC framework or by rApps. +- AI/ML model management and exposure services: Services are produced by the SMO/Non-RT RIC framework and enable + - AI/ML model registration/deregistration: It allows an rApp to register, update the registration of, and deregister the AI/ML model that it provides. An rApp needs to be authorised to register, update the registration of, or deregister the AI/ML model it provides. + - AI/ML model discovery: It allows an rApp to discover registered AI/ML model(s) based on its selection criteria if it is provided. An rApp needs to be authorised to discover registered AI/ML models. + - AI/ML model change subscription: It allows an rApp to subscribe and receive notifications of changes of a registered AI/ML model. + - AI/ML model storage: It allows an rApp to request the storage of an AI/ML model it registered and the AI/ML model associated information. + - AI/ML model training capability registration/deregistration (optional service): It allows an AI/ML training service Producer to register/update/deregister its capability of training an AI/ML model. + +- AI/ML model training capability query (optional service): It allows an rApp to query registered AI/ML model training capability based on its selection criteria if it is provided. An rApp needs to be authorised to query registered AI/ML model training capability. +- AI/ML model retrieve: It allows an rApp to request model location details of a specific version of a registered AI/ML model. +- AI/ML model performance monitoring services: These services allow an authorised AI/ML performance monitoring service Consumer to request monitoring the performance of a deployed AI/ML model. The AI/ML model performance monitoring service can be produced by the SMO/Non-RT RIC framework or by rApps. The performance information of an AI/ML model is produced by the rApp within which the model is deployed or by AI/ML model inference service Producer performing the model inference. +- AI/ML model inference services: These services allow an rApp to request and or to cancel the inference for a registered AI/ML model. The rApp needs to be authorised to request inference for registered AI/ML models. AI/ML inference services can be produced by the SMO/Non-RT RIC framework or by rApps. + +NOTE 1: Void. + +NOTE 2: An authorized rApp can request deployment of a specific version of a registered AI/ML model. + +## 7.8 rApp management services + +The following rApp management services are defined: + +- rApp registration service: This service allows rApp to register with the rApp management services Producer. +- rApp configuration service: This service allows rApp configuration settings to be set and read. +- rApp performance service: This service allows an rApp to report on the performance of the rApp itself or its communication with other entities. +- rApp fault service: This service allows an rApp to report faults that are related to the rApp itself or to its communication with other entities. +- rApp log information service: This service allows an rApp to convey the log information that the rApp wishes to report. + +## 7.9 TE&IV-related services + +TE&IV-related services in SMO/Non-RT RIC framework enable rApps to access topology and inventory information. Relationship information between various TE&IV resource types (e.g., RAN resources and O-Cloud resources) is an example of topology information. + +# 8 Non-RT RIC Function Definitions + +## 8.1 General description + +In the Non-RT RIC architecture in clause 6, R1 services are provided by a collection of logical functions in SMO/Non-RT RIC framework or rApps. These logical functions, as defined in clause 6, include (but are not limited to): + +- Service management and exposure functions: These functions produce service management and exposure services. +- Data management and exposure functions: These functions produce data management and exposure services. +- AI/ML workflow functions: These functions produce AI/ML workflow services. +- rApp management functions: These functions produce rApp management services. +- AI-related functions: These functions produce AI-related services. + +- RAN OAM-related functions: These functions produce RAN OAM-related services. +- O2-related functions: These functions produce O2-related services. +- R1 termination: It enables the R1 Service Producers and R1 Service Consumers to exchange messages via the R1 interface. +- A1 termination: It enables the Non-RT RIC framework and the Near-RT RIC to exchange messages over the A1 interface. +- O1 termination: It enables the SMO framework to exchange messages with the Near-RT RIC/E2 nodes over the O1 interface. +- Open fronthaul M-plane termination: It enables the SMO framework to exchange messages with the O-RUs over the open fronthaul M-plane interface. +- O2 termination: It enables the SMO framework to exchange messages with the O-Cloud over the O2 interface. +- Other SMO functions: Among other functionalities, these functions also offer RAN-specific slice management functionality. +- External terminations: These functions enable the SMO/Non-RT RIC framework to exchange messages with external entities over interfaces outside the scope of O-RAN. + +NOTE: The SMO functions offering the slice management services and whether these shall be considered as R1 services is for future study. + +## 8.2 Service management and exposure functions + +### 8.2.1 Service registration and discovery functions + +The service registration and discovery functions are logical functions that produce the service registration, service deregistration, service discovery, service notification, communication support services and optional bootstrap and heartbeat services specified in clause 7.2. + +Examples of Service Producers include: service management and exposure services producer, A1-related services producer, etc. Examples of Service Consumers are rApps. It is noted that rApps can also be Service Producers and logical functions can also be Service Consumers. + +A Service Producer or an entity acting on its behalf can send a service registration request to the service registration and discovery functions to register services. A Service Consumer can either send a service discovery request to the service registration and discovery functions to discover the services and the endpoints on which they can be consumed, or it can send a service request directly if it receives a service notification with the related information on the service and on the endpoints on which it can be consumed. + +### 8.2.2 Authentication and authorisation functions + +The authentication and authorisation functions are logical functions that produce the authentication and authorisation services specified in clause 7.2. + +## 8.3 Data management and exposure functions + +The data management and exposure functions are logical functions that produce the data registration and discovery service, the data request and subscription service, the data offer service and optional data processing services specified in clause 7.3. They further initiate data collection by consuming the data request and subscription service. Additionally, they produce and consume the data delivery services in order to obtain collected data from Data Producers and to allow Data Consumers to obtain data from the data management and exposure functions for consumption. + +The data management and exposure functions track DME types that are registered. They match data discovery requests against such DME types. If the DME type is registered, the data management and exposure functions identify a valid Data Producer, which can be a previously registered Data Producer rApp or other Data Producers in the SMO/Non-RT RIC framework (e.g., + +RAN OAM-related functions). The data management and exposure functions optionally provide data processing functionality on collected data (e.g., quantization, normalization, correlation, labelling, etc.). + +When Data Consumers use the subscribe data procedure to initiate continuous data consumption, the data management and exposure functions check the availability of the subscribed data after receiving a data subscription request from a Data Consumer. If the subscribed data are already being collected, the data management and exposure functions deliver the data to the Data Consumer when they become available. If the data are not already being collected and a valid Data Producer is identified, the data management and exposure functions initiate data collection to obtain data from the identified Data Producer. When the collected data become available, the data management and exposure functions deliver the data to the Data Consumer. + +When Data Consumers use the request data procedure to initiate one-time data consumption, the data management and exposure functions check the availability of the required data after receiving a one-time data request from a Data Consumer. If the requested data are available, the data management and exposure functions deliver the data to the Data Consumer. If the data are not available and a valid Data Producer is identified, the data management and exposure functions initiate data collection to obtain data from the identified Data Producer. When the collected data become available, the data management and exposure functions deliver the data to the Data Consumer. + +When a Data Producer uses the create data offer procedure to trigger data collection, the data management and exposure functions set up an endpoint for receiving data availability notifications or push data messages (depending on the delivery method chosen) and confirm the creation of the data offer to the Data Producer. Data collection starts once the data offer creation is confirmed and proceeds until the data offer is terminated by the Data Producer or by the data management and exposure functions. The data management and exposure functions store the collected data for later consumption. + +The use of a data repository for storing data during data collection is optional if data collection was triggered by a data request or data subscription from a Data Consumer. It is required if data collection was triggered by a data offer from a Data Producer. Data can be optionally pre-processed before being stored and can be optionally post-processed after being read. + +NOTE: Instead of storing data in a data repository, data management and exposure functions can broker data from Data Producers to Data Consumers. + +## 8.4 A1-related functions + +### 8.4.1 A1 policy functions + +The logical functions that produce the A1 policy management services which are exposed to rApps via the R1 interface are called the "A1 policy functions". They realize the following functionalities: + +- Producing A1 policy management services which are exposed to rApps via the R1 interface. + - The corresponding service definition can be found in clause 7.4.1. +- Performing A1 policy conflict mitigation. + - If more than one policy generation rApps set contradicting A1 policy statements to the same or overlapping policy scope identifiers, A1 policy function decides to reject the creation/modification request of one or more A1 policies or to temporarily suspend the enforcement of one or more A1 policies. +- Interfacing with Near-RT RICs through A1 termination + - A1 policy function determines the Near-RT RIC for generated A1 policies. + - A1 policy function sends A1 policy creation, update, and deletion requests to the Near-RT RIC. + - A1 policy function queries supported A1 policy types of connected Near-RT RICs. + - A1 policy function queries enforcement status of A1 policies. + - A1 policy function receives A1 policy feedback from the Near-RT RIC. + +### 8.4.2 A1 enrichment information functions + +“A1 enrichment information functions” produce the A1 enrichment information related services which are exposed to rApps via the R1 interface. The corresponding services definition can be found in clause 7.4.2. “A1 enrichment information functions” also produce the A1-EI service which is exposed to Near-RT RICs via the A1 interface. The corresponding service definition can be found in the A1 interface specification, see references in clause 9.1. “A1 enrichment information functions” collect data that are to be delivered as EI job results to Near-RT RICs via the data management and exposure functions. + +NOTE: The data delivered as EI job results can be produced by rApps or by external enrichment information sources. + +“A1 enrichment information functions” realize the following functionalities: + +- Handling of EI types registered by rApps via the R1 interface. +- Handling of EI jobs created by the Near-RT RICs via the A1 interface. +- Collecting data that are to be delivered as EI job results to the Near-RT RICs via the A1 interface. +- Interfacing with Near-RT RICs through A1 termination. + +## 8.5 RAN OAM-related functions + +The logical functions that produce the RAN OAM-related services which are exposed to rApps via the R1 interface are called the “RAN OAM-related functions”. They realize the following functionalities: + +- Producing RAN OAM-related services which are exposed to rApps via the R1 interface. + - The corresponding service definition can be found in clause 7.5. +- Performing CM conflict mitigation. +- Interfacing with Near-RT RICs and E2 nodes through O1 termination. + - RAN OAM-related functions receive fault notifications and obtain alarm list from Near-RT RICs and E2 nodes. + - RAN OAM-related functions provision configuration changes to Near-RT RICs and E2 nodes. + - RAN OAM-related functions collect performance data from Near-RT RICs and E2 nodes. + - RAN OAM-related functions collect trace data from E2 nodes. +- Interfacing with the O-RUs through open fronthaul M-plane termination. + - RAN OAM-related functions receive fault notifications and obtain alarm list from the O-RUs. + - RAN OAM-related functions provision configuration changes to the O-RUs. + - RAN OAM-related functions collect performance data from the O-RUs. +- Interfacing with the RAN-specific slice management functionality in the SMO framework. + - RAN OAM-related functions provision configuration changes, related to RAN-specific network slicing. + - RAN OAM-related functions collect performance data, related to RAN-specific network slicing. + +## 8.6 O2-related functions + +The O2 interface is an open logical interface within O-RAN architecture. The logical functions that produce the O2-related services which are exposed to rApps via the R1 interface are called the “O2-related functions”. O2-related functions include FOCOM and NFO. They realize the following functionalities: + +- Producing O2-related services which are exposed to rApps via the R1 interface. + +- The corresponding service definition can be found in clause 7.6. +- Interfacing with O-Cloud through O2 termination. + - O2-related functions receive O-Cloud infrastructure FCAPS (PM, CM, FM) data via O-Cloud IMS, see O-RAN O2GAP [13]. + - O2-related functions receive O-Cloud deployment FCAPS (PM, CM, FM) data via O-Cloud DMS, see O-RAN O2GAP [13]. + - O2-related functions provision configuration changes to O-Cloud. +- Performing conflict mitigation for O-Cloud configuration changes. + +## 8.7 AI/ML workflow functions + +The AI/ML workflow functions are logical functions that produce the following AI/ML workflow services as specified in clause 7.7: + +- AI/ML training services. +- AI/ML model management and exposure services, which enables AI/ML model registration/deregistration, AI/ML model discovery, AI/ML model change subscription, AI/ML model storage and optionally AI/ML model training capability registration/deregistration/query. +- AI/ML model performance monitoring services. +- AI/ML model inference services. + +# --- 9 External Interfaces + +## 9.1 A1 Interface + +O-RAN A1GAP [4] specifies A1 interface general aspects and principles. + +O-RAN A1AP [5] specifies A1 interface application protocols. + +O-RAN A1TP [6] specifies A1 interface transport protocols. + +O-RAN A1TD [7] specifies data model and data types used in the A1 interface. + +## 9.2 Void + +# --- 10 Procedures + +## 10.1 Data management and exposure procedures + +### 10.1.0 Overview + +This clause demonstrates example procedures related to data management and exposure (DME) services produced and consumed by SMO/Non-RT RIC framework. A Data Consumer rApp requests/subscribes data from SMO/Non-RT RIC framework, and the requested/subscribed data are collected from another Data Producer rApp or other O-RAN entities. + +NOTE: It is not required to use the same type of DME services procedure in data consumption and data collection. + +Data consumption denotes the procedures of Data Consumer rApp requesting/subscribing data from SMO/Non-RT RIC framework. Data collection denotes the procedures of SMO/Non-RT RIC framework requesting/subscribing data from Data Producer rApps or other O-RAN entities. + +### 10.1.1 Subscribe data procedures in data consumption and collection + +Figure 10.1.1-1 illustrates an example workflow of using DME services to subscribe data and deliver data over the R1 interface. In this example, it is assumed that + +- Two Data Consumer rApps subscribe the same data instance (i.e., same DME type and scope) from the DME functions. +- The requested data are produced by a Data Producer rApp. +- The DME functions subscribe data instance from the Data Producer rApp. +- Data are delivered using pull or push data delivery or by point to multipoint streaming data delivery. In case of pull delivery, the pull delivery details can be contained in subscribe data response or data availability notification. The Data Consumer makes a pull request based on the received pull delivery details. In case of point to multipoint streaming data delivery, DME functions inform the Data Consumer which data stream endpoint to consume the subscribed data from. + +When the first Data Consumer rApp initiates the Subscribe data procedure to obtain data, the DME functions first identify the Data Producer for the requested data instance. In this example, one Data Producer rApp which is already registered as being capable of producing the subscribed data are identified as the Data Producer. The DME functions figure out there is no data subscription for the requested data instance yet, and the DME functions subscribe data from Data Producer rApp. In case of pull delivery, the Data Producer rApp notifies the data availability to the DME functions and provides pull data details in the notification. The DME functions then pull data from the Data Producer rApp. In case of push delivery, the Data Producer rApp pushes the data to the DME functions. The DME functions may optionally process the data or store the data in the data repository for future usage. In case of pull delivery, the DME functions further notify the data availability to the first Data Consumer rApp. The rApp then pulls the data from the DME functions. In case of push delivery, the DME functions push the data to the Data Consumer rApp. In case of point to multipoint streaming data delivery, the DME functions configures the data stream endpoint unless it is already configured. The Data Producer rApp writes the data to the stream endpoint and Data Consumer rApp reads the data from the stream endpoint. + +When the second Data Consumer rApp sends a data subscription request to the DME functions, the DME functions find out that the data subscription for the requested data instance is already established. Therefore, the DME functions do not set up additional data subscription with the Data Producer rApp. Once new data are available, the following steps are executed: In case of pull delivery, the Data Producer notifies the data availability to the DME functions, and these pull the data from the Data Producer. In case of push delivery, the Data Producer pushes the data to the DME functions. The DME functions may optionally process the data and store the data in the data repository for future usage. In case of pull delivery, the DME functions further notify the data availability to both Data Consumer rApps which then pull the data from the DME functions. In case of push delivery, the DME functions push the data to both Data Consumer rApps. In case of point to multipoint streaming data delivery, the DME functions inform the second Data Consumer rApp which data stream endpoint to use. The Data Producer rApp writes the data to the data stream endpoint and the Data Consumer rApp reads the data from the data stream endpoint. + +The DME functions can use different procedures to deliver data to Data Consumer rApps even if both Data Consumer rApps subscribe the same data instance. For example, the DME functions can notify data availability to the one Data Consumer rApp allowing the rApp to pull data, meanwhile the DME functions push data to another Data Consumer or both the Data Consumer rApps read the data from the data stream endpoint provided by the DME functions. + +NOTE 1: Push content can be (1) notifications that carry a data payload or (2) streams of data. + +NOTE 2: Notifications, pull data delivery, and push data delivery may require the set-up of a dedicated communication channel that allows the content to be pulled/pushed. Such dedicated communication channels may map to, e.g., Kafka topic, WebSocket connection, gRPC connection, etc. Alternatively, individual HTTP requests may be used as push messages. + +``` +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +``` + +``` + +skinparam SequenceGroupBodyBackgroundColor Transparent +autonumber + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "Data Consumer rApp #1" as app1 + participant "Data Consumer rApp #2" as app2 + endbox + + box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "Data Management and Exposure functions" as dme + endbox + + box #ivory + participant "Data Producer rApp" as src + endbox +endbox + +group Data Consumer rApp #1 subscribes data +app1 -> dme : <> Subscribe data request +alt Pull or push data delivery +app1 <- dme : <> Subscribe data response +else Point to multipoint streaming data delivery +dme --> dme : Configure data stream endpoint +app1 <- dme : <> Subscribe data response (data stream endpoint) +end +end + +dme --> dme : Find out that data instance\nis not being collected;\nidentify the Data Producer + +group DME functions subscribes data from Data Producer rApp +alt Pull or push data delivery +src <- dme : <> Subscribe data request +else Point to multipoint streaming data delivery +src <- dme: <> Subscribe data request (data stream endpoint) +end +src -> dme : <> Subscribe data response +end + +loop data available +alt Pull delivery + src -> dme : <> Notify data availability (pull delivery details) + src <- dme : <> Pull data request + src -> dme : <> Pull data response (with data payload) +else Push delivery + src -> dme : <> Push data message (with data payload) +end +opt +dme --> dme : Processing data +end +opt +dme --> dme: Storing data +end + +alt Pull delivery + app1 <- dme : <> Notify data availability (pull delivery details) + app1 -> dme : <> Pull data request + app1 <- dme : <> Pull data response (with data payload) +else Push delivery + app1 <- dme : <> Push data message (with data payload) +end +end + +group Data Consumer rApp #2 subscribes data +app2 -> dme : <> Subscribe data request +alt Pull or push data delivery +app2 <- dme : <> Subscribe data response + +``` + +``` + +else Point to multipoint streaming data delivery +dme <-- dme : Configure data stream endpoint +app2 <- dme : <> Subscribe data response (data stream endpoint) +end +end + +dme --> dme : Find out that data instance\nis already being collected + +loop data available +alt Pull delivery + src -> dme : <> Notify data availability (pull delivery details) + src <- dme : <> Pull data request + src -> dme : <> Pull data response (with data payload) +else Push delivery + src -> dme : <> Push data message (with data payload) +end +opt +dme --> dme : Processing data +end +opt +dme --> dme: Storing data +end + +alt Pull delivery + app1 <- dme : <> Notify delivery details (pull delivery details) + app1 -> dme : <> Pull data request + app1 <- dme : <> Pull data response (with data payload) + app2 <- dme : <> Notify data availability (pull delivery details) + app2 -> dme : <> Pull data request + app2 <- dme : <> Pull data response (with data payload) +else Push delivery + app1 <- dme : <> Push data message (with data payload) + app2 <- dme : <> Push data message (with data payload) +end +end +@enduml + +``` + +![Sequence diagram showing the workflow for Data Management and Exposure functions in a Non-RT RIC. The diagram involves four main entities: Data Consumer rApp #1, Data Consumer rApp #2, Data Management and Exposure functions (DME), and Data Producer rApp. The workflow is divided into two main sections: 'Data Consumer rApp #1 subscribes data' and 'Data Consumer rApp #2 subscribes data'. Each section includes steps for subscribing data, configuring data stream endpoints, and handling data delivery (pull or push). The DME functions also subscribe data from the Data Producer rApp and manage data processing and storage. The diagram uses standard sequence diagram notation with numbered messages, alt blocks for conditional execution, and loop blocks for repeated actions.](0dd4f15e2754a6a0c0c6431c47fe608e_img.jpg) + +``` + +sequenceDiagram + participant DC1 as Data Consumer rApp #1 + participant DC2 as Data Consumer rApp #2 + participant DME as Data Management and Exposure functions + participant DP as Data Producer rApp + + Note over DME: Non-RT RIC + Note over DME: Non-anchored functions in SMO/Non-RT RIC FWK + Note over DME: Data Management and Exposure functions + + DC1->>DME: 1 «R1» Subscribe data request + alt [Pull or push data delivery] + DME->>DC1: 2 «R1» Subscribe data response + else [Point to multipoint streaming data delivery] + DME->>DP: 3 Configure data stream endpoint + DP-->>DME: + DME->>DC1: 4 «R1» Subscribe data response (data stream endpoint) + end + + Note over DME: Find out that data instance 5 is not being collected. Identify the Data Producer + DME->>DP: + alt [Pull or push data delivery] + DP->>DME: 6 «R1» Subscribe data request + DME->>DP: [Point to multipoint streaming data delivery] + DP->>DME: 7 «R1» Subscribe data request (data stream endpoint) + DME->>DP: 8 «R1» Subscribe data response + end + + loop [data available] + alt [Pull delivery] + DME->>DP: 9 «R1» Notify data availability (pull delivery details) + DP->>DME: 10 «R1» Pull data request + DME->>DP: 11 «R1» Pull data response (with data payload) + else [Push delivery] + DME->>DP: 12 «R1» Push data message (with data payload) + end + opt + DME->>DME: 13 Processing data + end + opt + DME->>DME: 14 Storing data + end + alt [Pull delivery] + DME->>DP: 15 «R1» Notify data availability (pull delivery details) + DP->>DME: 16 «R1» Pull data request + DME->>DP: 17 «R1» Pull data response (with data payload) + else [Push delivery] + DME->>DP: 18 «R1» Push data message (with data payload) + end + end + + DC2->>DME: 19 «R1» Subscribe data request + alt [Pull or push data delivery] + DME->>DC2: 20 «R1» Subscribe data response + else [Point to multipoint streaming data delivery] + DME->>DP: 21 Configure data stream endpoint + DP-->>DME: + DME->>DC2: 22 «R1» Subscribe data response (data stream endpoint) + end + + Note over DME: Find out that data instance is already being collected + DME->>DP: 23 + + loop [data available] + alt [Pull delivery] + DME->>DP: 24 «R1» Notify data availability (pull delivery details) + DP->>DME: 25 «R1» Pull data request + DME->>DP: 26 «R1» Pull data response (with data payload) + else [Push delivery] + DME->>DP: 27 «R1» Push data message (with data payload) + end + opt + DME->>DME: 28 Processing data + end + opt + DME->>DME: 29 Storing data + end + alt [Pull delivery] + DME->>DP: 30 «R1» Notify delivery details (pull delivery details) + DP->>DME: 31 «R1» Pull data request + DME->>DP: 32 «R1» Pull data response (with data payload) + DME->>DP: 33 «R1» Notify data availability (pull delivery details) + DP->>DME: 34 «R1» Pull data request + DME->>DP: 35 «R1» Pull data response (with data payload) + else [Push delivery] + DME->>DP: 36 «R1» Push data message (with data payload) + DME->>DP: 37 «R1» Push data message (with data payload) + end + end + +``` + +Sequence diagram showing the workflow for Data Management and Exposure functions in a Non-RT RIC. The diagram involves four main entities: Data Consumer rApp #1, Data Consumer rApp #2, Data Management and Exposure functions (DME), and Data Producer rApp. The workflow is divided into two main sections: 'Data Consumer rApp #1 subscribes data' and 'Data Consumer rApp #2 subscribes data'. Each section includes steps for subscribing data, configuring data stream endpoints, and handling data delivery (pull or push). The DME functions also subscribe data from the Data Producer rApp and manage data processing and storage. The diagram uses standard sequence diagram notation with numbered messages, alt blocks for conditional execution, and loop blocks for repeated actions. + +Figure 10.1.1-1: Example workflow using subscribe data and notify data availability procedures + +Figure 10.1.1-2 illustrates an example workflow of using unsubscribe data procedures to terminate data subscription in data consumption data and data collection. In the example, it is assumed that the two Data Consumer rApps in the figure are the only two Data Consumers which have subscribed the data instance produced by the Data Producer rApp. + +When the second Data Consumer rApp initiates the unsubscribe data procedure, the DME functions find out that the produced data are also subscribed by the first Data Consumer rApp. Therefore, the DME functions can't unsubscribe from the Data Producer rApp. + +When the first Data Consumer rApp initiates the unsubscribe data procedure, the DME functions figure out that the data subscription is no longer needed. Hence, in this example, the DME functions identify the Data Producer rApp and send an unsubscription request to cancel the data subscription. In case of point to multipoint streaming data delivery, the Data Producer rApp stops producing the data to the data stream endpoint. + +NOTE 3: The DME functions are not required to unsubscribe data from Data Producers even if there are no Data Consumers requesting or subscribing these data. The DME functions may collect data from Data Producers for its own purposes. + +``` +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent +autonumber + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "Data Consumer rApp #1" as app1 + participant "Data Consumer rApp #2" as app2 + endbox + + box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "Data Management and Exposure functions" as dme + endbox + + box #ivory + participant "Data Producer rApp" as src + endbox +endbox + +group Data Consumer rApp #2 unsubscribes data +app2 -> dme : <> Unsubscribe data request +app2 <- dme : <> Unsubscribe data response +end + +dme --> dme : Find out that data are subscribed \n by other Data Consumers + +group Data Consumer rApp #1 unsubscribes data +app1 -> dme : <> Unsubscribe data request +app1 <- dme : <> Unsubscribe data response +end + +dme --> dme : Find out that data subscription \n is no longer required;\nidentify the Data Producer + +opt DME unsubscribes data from Data Producer rApp +src <- dme : <> Unsubscribe data request +src -> dme : <> Unsubscribe data response +end + +@enduml +``` + +![Sequence diagram illustrating the unsubscribe data procedure in a Non-RT RIC environment. The diagram shows interactions between Data Consumer rApps, Data Management and Exposure functions, and a Data Producer rApp. The process involves two consumers unsubscribing, the DME functions checking for other subscribers, and then optionally unsubscribing from the Data Producer rApp.](9e3335c1da87b3270486f8690dcbcfed_img.jpg) + +``` + +sequenceDiagram + participant DC1 as Data Consumer rApp #1 + participant DC2 as Data Consumer rApp #2 + participant DME as Data Management and Exposure functions + participant DP as Data Producer rApp + + Note over DC2, DME: Data Consumer rApp #2 unsubscribes data + DC2->>DME: 1 «R1» Unsubscribe data request + DME-->>DC2: 2 «R1» Unsubscribe data response + + Note over DC1, DME: Data Consumer rApp #1 unsubscribes data + DC1->>DME: 4 «R1» Unsubscribe data request + DME-->>DC1: 5 «R1» Unsubscribe data response + + Note over DME: 3 Find out that data are subscribed by other Data Consumers + + Note over DME: 6 Find out that data subscription is no longer required; identify the Data Producer + + Note over DME, DP: opt [DME unsubscribes data from Data Producer rApp] + DME->>DP: 7 «R1» Unsubscribe data request + DP-->>DME: 8 «R1» Unsubscribe data response + end + +``` + +Sequence diagram illustrating the unsubscribe data procedure in a Non-RT RIC environment. The diagram shows interactions between Data Consumer rApps, Data Management and Exposure functions, and a Data Producer rApp. The process involves two consumers unsubscribing, the DME functions checking for other subscribers, and then optionally unsubscribing from the Data Producer rApp. + +**Figure 10.1.1-2: Example workflow using unsubscribe data procedure** + +### 10.1.2 Request data procedure in data consumption and data collection + +Figure 10.1.2-1 illustrates an example workflow of using DME services to request and deliver data over the R1 interface. In this example, it is assumed that + +- Two Data Consumer rApps request the same data instance (i.e., same DME type and scope) using request data procedure. +- The requested data are produced by a Data Producer rApp. +- The DME functions request data from the Data Producer rApp using request data procedure. +- Data are delivered using pull delivery. The pull delivery details are contained in the request data response. The Data Consumer makes a pull request based on the received pull delivery details. +- The pull delivery details provide Data Consumer information of how to formulate a pull data request for the delivery of requested data (e.g., a URI from which to fetch the data). + +When the first Data Consumer rApp initiates the request data procedure to obtain data, the DME functions first check whether the requested data are available in the data repository. In this example, it figures out that data are not available. Then the DME functions identify the Data Producer rApp as the Data Producer, e.g., based on DME type registration records. The DME functions send data request to the Data Producer rApp, and the data are delivered from the Data Producer rApp using pull delivery. The DME functions then send data request response to the first Data Consumer rApp carrying pull delivery details. The first Data Consumer rApp pulls data from the DME functions. The DME functions may optionally process data and store the data in the data repository for future usage. + +When the second Data Consumer rApp sends data request to the DME functions, the DME functions notice that the requested data are already available in the data repository. Then the DME functions retrieve requested data from data repository and responds the second Data Consumer rApp with pull delivery details. The data are pulled by the second Data Consumer rApp. + +``` + +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent +autonumber + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "Data Consumer rApp #1" as app1 + participant "Data Consumer rApp #2" as app2 + endbox + + box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "Data Management and Exposure functions" as dme + database "Data repository" as db + endbox + + box #ivory + participant "Data Producer rApp" as src + endbox +endbox +group Data Consumer rApp #1 requests data +app1 -> dme : <> Request data request +dme --> dme : Find out that requested data \n are not available in the data repository +app1 <- dme : <> Request data response (pull delivery details) + +group Obtain data not available in the repository +src <- dme : <> Request data request +src -> dme : <> Request data response (pull delivery details) +src <- dme : <> Pull data request +src -> dme : <> Pull data response (with data payload) +opt +dme --> dme : Processing data +end +opt +dme <--> db: Storing data +end +end + +app1 -> dme : <> Pull data request +app1 <- dme : <> Pull data response (with data payload) +end + +group Data Consumer rApp #2 requests data +app2 -> dme : <> Request data request +dme --> dme : Find out that requested data \n are available in the data repository +app2 <- dme : <> Request data response (pull delivery details) +group Obtain data that are available in the repository +dme <--> db: Retrieving data +end +app2 -> dme : <> Pull data request +app2 <- dme : <> Pull data response (with data payload) +end + +@enduml + +``` + +![Sequence diagram showing the workflow for data collection using request data procedure. The diagram is divided into two main sections: 'Non-RT RIC' and 'Non-anchored functions in SMO/Non-RT RIC FWK'. The 'Non-RT RIC' section includes 'Data Consumer rApp #1', 'Data Consumer rApp #2', and 'Data Producer rApp'. The 'Non-anchored functions in SMO/Non-RT RIC FWK' section includes 'Data Management and Exposure functions' and 'Data repository'. The workflow starts with 'Data Consumer rApp #1 requests data', followed by a sequence of messages (1-17) involving requests, responses, and data retrieval from the repository. The diagram also shows optional steps for processing and storing data.](c17df69740c9a43f50eb17a847420477_img.jpg) + +``` + +sequenceDiagram + participant DC1 as Data Consumer rApp #1 + participant DC2 as Data Consumer rApp #2 + participant DME as Data Management and Exposure functions + participant DR as Data repository + participant DP as Data Producer rApp + + Note over DME, DR: Non-anchored functions in SMO/Non-RT RIC FWK + + DC1->>DME: 1 «R1» Request data request + DME->>DR: 2 Find out that requested data are not available in the data repository + DR-->>DME: + DME->>DC1: 3 «R1» Request data response (pull delivery details) + + Note over DME, DR: Obtain data not available in the repository + DME->>DP: 4 «R1» Request data request + DP->>DME: 5 «R1» Request data response (pull delivery details) + DME->>DR: 6 «R1» Pull data request + DR->>DME: 7 «R1» Pull data response (with data payload) + + Note over DME: opt + DME->>DME: 8 Processing data + DME-->>DME: + Note over DME: opt + DME->>DR: 9 Storing data + DR-->>DME: + + DC1->>DME: 10 «R1» Pull data request + DME->>DC1: 11 «R1» Pull data response (with data payload) + + Note over DC2, DME, DR: Data Consumer rApp #2 requests data + DC2->>DME: 12 «R1» Request data request + DME->>DR: 13 Find out that requested data are available in the data repository + DR-->>DME: + DME->>DC2: 14 «R1» Request data response (pull delivery details) + + Note over DME, DR: Obtain data that are available in the repository + DME->>DR: 15 Retrieving data + DR-->>DME: + + DC2->>DME: 16 «R1» Pull data request + DME->>DC2: 17 «R1» Pull data response (with data payload) + +``` + +Sequence diagram showing the workflow for data collection using request data procedure. The diagram is divided into two main sections: 'Non-RT RIC' and 'Non-anchored functions in SMO/Non-RT RIC FWK'. The 'Non-RT RIC' section includes 'Data Consumer rApp #1', 'Data Consumer rApp #2', and 'Data Producer rApp'. The 'Non-anchored functions in SMO/Non-RT RIC FWK' section includes 'Data Management and Exposure functions' and 'Data repository'. The workflow starts with 'Data Consumer rApp #1 requests data', followed by a sequence of messages (1-17) involving requests, responses, and data retrieval from the repository. The diagram also shows optional steps for processing and storing data. + +Figure 10.1.2-1: Example workflow using request data procedure + +### 10.1.3 O1 related data collection procedures based on data subscription + +Figure 10.1.3-1 illustrates an example workflow of how DME functions in the SMO/Non-RT RIC framework collect O1-related data based on the data subscription from a Data Consumer rApp. + +In this example, when the Data Consumer rApp initiates the subscribe data procedure to obtain O1 related data, the DME functions acknowledge the data subscription, and check whether subscribed data are being collected already or not. If the subscribed data are not being collected, the DME functions initiates data collection procedure to collect from nodes terminating the O1 interface via the RAN OAM-related functions. The related procedures have been specified in O-RAN OAM Arch [8], clause 4.2.2 “O-RAN Measurement Data Collection Use Case”. When the DME functions receive the collected data from the RAN OAM-related functions, they notify the Data Consumer rApp, and the subscribed data are delivered using pull or push data services. + +NOTE: Data delivery procedures are defined in O-RAN R1GAP [9], clause 5.2.6. + +``` + +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent +skinparam sequenceReferenceHeaderBackgroundColor Transparent +autonumber + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "Data Consumer rApp" as dc + endbox + + box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "Data Management and Exposure functions" as dme + participant "RAN OAM-related functions" as OAM + endbox +endbox +participant "Nodes terminating O1 interface" as dp +autonumber + +dc -> dme : <> Subscribe data request +dme ->dc : <> Subscribe data response + +dme --> dme : check if the subscribed data are being collected already + +group if subscribed data are not being collected yet +dme <--> OAM : Implementation specific communication +ref over OAM, dp + As specified in Clause 4.2.2.3.1 + "Measurement Data Collection Creation" + in O-RAN.WG10.OAM-Architecture +end +end + +loop data available +alt File-based delivery +ref over OAM, dp + As specified in Clause 4.2.2.3.2 + "Measurement Data File Consumption" + in O-RAN.WG10.OAM-Architecture +end +else Streaming delivery +ref over OAM, dp + As specified in Clause 4.2.2.3.3 + "Measurement Streaming Data Consumption" + in O-RAN.WG10.OAM-Architecture +end +end +OAM --> dme : implementation-specific data delivery +alt pull delivery +dme -> dc: <> Notify data availability (pull delivery details) +dc -> dme: <> Pull data request +dme -> dc: <> Pull data response (data payload) +else push delivery +dme -> dc : <>Push data message (data payload) +end +end + +@enduml + +``` + +![Sequence diagram illustrating the example workflow for O1 related data collection procedure via DME. The diagram shows interactions between a Data Consumer rApp and the Non-RT RIC framework, which includes Data Management and Exposure functions and RAN OAM-related functions. The workflow starts with a 'Subscribe data request' (1) and a 'Subscribe data response' (2). A check (3) determines if data is already being collected. If not, an 'Implementation specific communication' (4) is initiated, referencing Clause 4.2.2.3.1. A loop labeled '[data available]' follows, containing an 'alt' block for '[pull delivery]' (steps 6-8) and '[push delivery]' (step 9). Delivery methods are further detailed in an 'alt' block for '[File-based delivery]' (referencing Clause 4.2.2.3.2) and '[Streaming delivery]' (referencing Clause 4.2.2.3.3). The diagram also shows 'Nodes terminating O1 interface'.](cf858b014f14b4d4fb83458546cd1475_img.jpg) + +Sequence diagram illustrating the example workflow for O1 related data collection procedure via DME. The diagram shows interactions between a Data Consumer rApp and the Non-RT RIC framework, which includes Data Management and Exposure functions and RAN OAM-related functions. The workflow starts with a 'Subscribe data request' (1) and a 'Subscribe data response' (2). A check (3) determines if data is already being collected. If not, an 'Implementation specific communication' (4) is initiated, referencing Clause 4.2.2.3.1. A loop labeled '[data available]' follows, containing an 'alt' block for '[pull delivery]' (steps 6-8) and '[push delivery]' (step 9). Delivery methods are further detailed in an 'alt' block for '[File-based delivery]' (referencing Clause 4.2.2.3.2) and '[Streaming delivery]' (referencing Clause 4.2.2.3.3). The diagram also shows 'Nodes terminating O1 interface'. + +**Figure 10.1.3-1: Example workflow for O1 related data collection procedure via DME** + +### 10.1.4 O2 related data collection procedures based on data subscription + +Figure 10.1.4-1 illustrates an example workflow of how DME functions in the SMO/Non-RT RIC framework collect O2 related data based on the data subscription from a Data Consumer rApp. + +In this example, when the Data Consumer rApp initiates the subscribe data procedure to obtain O2 related data, the DME functions acknowledge the data subscription, and check whether subscribed data are being collected already or not. If the subscribed data are not being collected, the DME functions initiate Data collection procedure to collect from DMS via the O2 related functions. This procedure has been specified in O-RAN OAM Arch [8], clause 4.2.2 “O-RAN Measurement Data Collection Use Case”. When the DME functions receive the collected data from the O2 related functions, it notifies the Data Consumer rApp, and the subscribed data are delivered using pull or push data services. + +NOTE: Data delivery procedures are defined in O-RAN R1GAP [9], clause 5.2.6. + +``` +@startuml +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent +skinparam sequenceReferenceHeaderBackgroundColor Transparent +``` + +``` + +autonumber + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "Data Consumer rApp" as dc + endbox + + box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "Data Management and Exposure functions" as dme + participant "O2 related functions" as OAM + endbox +endbox +participant "DMS" as dp +autonumber + +dc -> dme : <> Subscribe data request +dme ->dc : <> Subscribe data response + +dme --> dme : Check if the subscribed data are being collected already + +group if subscribed data are not being collected yet +dme <--> OAM : Implementation specific communication +ref over OAM, dp + As specified in Clause 4.2.2.3.1 + "Measurement Data Collection Creation" + in O-RAN.WG10.OAM-Architecture +End +End + +loop data available +alt File-based delivery +ref over OAM, dp + As specified in Clause 4.2.2.3.2 + "Measurement Data File Consumption" + in O-RAN.WG10.OAM-Architecture +end +else Streaming delivery +ref over OAM, dp + As specified in Clause 4.2.2.3.3 + "Measurement Streaming Data Consumption" + in O-RAN.WG10.OAM-Architecture +end +end +OAM --> dme : Implementation-specific data delivery +alt pull delivery +dme -> dc: <> Notify data availability (pull delivery details) +dc -> dme: <> Pull data request +dme -> dc: <> Pull data response (data payload) +else push delivery +dme -> dc : <> Push data message (data payload) +end +end + +@enduml + +``` + +![Sequence diagram showing the workflow for O2 related data collection procedure via DME. The diagram involves four main components: Data Consumer rApp, Non-anchored functions in SMO/Non-RT RIC FWK (containing Data Management and Exposure functions and O2 related functions), DMS, and Data Producer rApp. The workflow starts with a subscribe request, followed by a response and a check for data collection. If not collected, it triggers implementation-specific communication. A loop then occurs where data is available, leading to either pull or push delivery. Pull delivery involves a request for details and a response with payload. Push delivery involves a direct message with payload. Both delivery methods reference specific clauses in O-RAN.WG10.QAM-Architecture for file-based and streaming delivery.](c8a411a4bae96a0905d6730776dab076_img.jpg) + +``` + +sequenceDiagram + participant DC as Data Consumer rApp + participant SMO as Non-anchored functions in SMO/Non-RT RIC FWK + participant DMS + participant DP as Data Producer rApp + + Note over SMO: Data Management and Exposure functions + Note over SMO: O2 related functions + + DC->>SMO: 1 «R1» Subscribe data request + SMO-->>DC: 2 «R1» Subscribe data response + SMO->>SMO: 3 Check if the subscribed data are being collected already + SMO-->>SMO: if subscribed data are not being collected yet + SMO->>SMO: 4 Implementation specific communication + SMO-->>SMO: ref: As specified in Clause 4.2.2.3.1 "Measurement Data Collection Creation" in O-RAN.WG10.QAM-Architecture + SMO->>SMO: loop: [data available] + alt [pull delivery] + SMO-->>DP: 6 «R1» Notify data availability (pull delivery details) + DP->>SMO: 7 «R1» Pull data request + SMO-->>DP: 8 «R1» Pull data response (data payload) + else [push delivery] + SMO-->>DP: 9 «R1» Push data message (data payload) + end + SMO->>SMO: 5 Implementation-specific data delivery + alt [File-based delivery] + SMO-->>SMO: ref: As specified in Clause 4.2.2.3.2 "Measurement Data File Consumption" in O-RAN.WG10.QAM-Architecture + else [Streaming delivery] + SMO-->>SMO: ref: As specified in Clause 4.2.2.3.3 "Measurement Streaming Data Consumption" in O-RAN.WG10.QAM-Architecture + end + +``` + +Sequence diagram showing the workflow for O2 related data collection procedure via DME. The diagram involves four main components: Data Consumer rApp, Non-anchored functions in SMO/Non-RT RIC FWK (containing Data Management and Exposure functions and O2 related functions), DMS, and Data Producer rApp. The workflow starts with a subscribe request, followed by a response and a check for data collection. If not collected, it triggers implementation-specific communication. A loop then occurs where data is available, leading to either pull or push delivery. Pull delivery involves a request for details and a response with payload. Push delivery involves a direct message with payload. Both delivery methods reference specific clauses in O-RAN.WG10.QAM-Architecture for file-based and streaming delivery. + +**Figure 10.1.4-1: Example workflow for O2 related data collection procedure via DME** + +### 10.1.5 Data offer procedures + +Figure 10.1.5-1 illustrates an example workflow of using the DME services by a Data Producer to trigger the DME functions to collect a data instance produced by that Data Producer and to store it for later consumption. + +The Data Producer rApp first needs to register a DME type for the data instance it intends to produce. The rApp then initiates the create data offer procedure to trigger the collection of a data instance of that DME type which it intends to produce. The parameters of the data instance and the supported delivery services are indicated in the request. After receiving the request, the DME functions first check whether the Data Producer has registered the DME type for which it intends to produce an instance. Upon success, the DME functions set up an endpoint for the reception of data availability notifications or push data messages, depending on the delivery service chosen, and communicate this information to the Data Producer. Data collection can start immediately after the data offer creation has been acknowledged by the DME functions. + +When data are available, the Data Producer sends a data availability notification to the DME functions and these pull the data, or the Data Producer pushes the data to the DME functions. Then, the DME functions store these data for subsequent consumption. + +When the Data Producer intends to stop data production, it terminates the data offer by using the terminate data offer procedure. Data collection ends upon successful execution of that procedure. When the data management and exposure functions intend to stop receiving produced data, they send a data offer termination notification to the Data Producer. Subsequently, possibly after a delay to allow the Data Producer to react to the notification, the data management and exposure + +functions stop data collection and terminate the data offer. Upon receiving this notification, the Data Producer stops data production. + +``` + +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent +skinparam lifelineStrategy solid +autonumber + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "Data Producer rApp" as rapp + endbox + + box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "Data Management and\nExposure functions" as dme + database "Data repository" as db + endbox +endbox + +group Data Producer rApp registers DME type + rapp -> dme: <> Register DME type request + rapp <- dme: <> Register DME type response +end + +group Data Producer rApp creates data offer + rapp -> dme: <> Create data offer request(info about data instance and delivery) + dme --> dme: Create data offer\nand prepare\ndelivery endpoint + dme -> rapp: <> Create data offer response (endpoint details for notify data +availability\nor push data) +end + +group Data are collected from Data Producer rApp + loop data available + alt pull delivery + rapp -> dme: <> Notify data availability (pull details) + dme -> rapp: <> Pull data request + rapp -> dme: <> Pull data response (data) + else push delivery + rapp -> dme: <> Push data (data) + end + dme <--> db: Store data + end +end + +group Data offer termination + alt Data Producer rApp terminates data offer + rapp -> dme: <> Terminate data offer request + dme --> dme: Delete data offer and\nstop collecting data + dme -> rapp: <> Terminate data offer response + else DME functions terminate data offer + dme -> rapp: <> Notify data offer termination + dme --> dme: Stop collecting data\nand terminate data offer + rapp --> rapp: Stop producing data + end +end + +@enduml + +``` + +![Sequence diagram showing the interaction between Data Producer rApp and Non-RT RIC components (Data Management and Exposure functions, Data repository) for DME type registration, data offer creation, data collection, and data offer termination.](10d2072a16f946b173f0f17245646e56_img.jpg) + +**Non-RT RIC** + +``` + +sequenceDiagram + participant DP as Data Producer rApp + participant DM as Data Management and Exposure functions + participant DR as Data repository + + Note over DP: Data Producer rApp registers DME type + DP->>DM: 1 «R1» Register DME type request + DM-->>DP: 2 «R1» Register DME type response + + Note over DP: Data Producer rApp creates data offer + DP->>DM: 3 «R1» Create data offer request(info about data instance and delivery) + Note over DM: Create data offer 4 and prepare delivery endpoint + DM-->>DP: 5 «R1» Create data offer response (endpoint details for notify data availability or push data) + + Note over DP: Data are collected from Data Producer rApp + loop [data available] + alt [pull delivery] + DP->>DM: 6 «R1» Notify data availability (pull details) + DM-->>DP: 7 «R1» Pull data request + DP->>DM: 8 «R1» Pull data response (data) + and [push delivery] + DP->>DM: 9 «R1» Push data (data) + end + DM-->>DR: 10 Store data + end + + Note over DP: Data offer termination + alt [Data Producer rApp terminates data offer] + DP->>DM: 11 «R1» Terminate data offer request + DM-->>DP: 12 Delete data offer and stop collecting data + DM-->>DP: 13 «R1» Terminate data offer response + and [DME functions terminate data offer] + DP-->>DM: 14 «R1» Notify data offer termination + DM-->>DP: 15 Stop collecting data and terminate data offer + end + DP-->>DP: 16 Stop producing data + +``` + +The diagram illustrates the interaction between the Data Producer rApp and the Non-RT RIC components (Data Management and Exposure functions and Data repository) for DME type registration, data offer creation, data collection, and data offer termination. + +**Data Producer rApp registers DME type** + +- 1 «R1» Register DME type request +- 2 «R1» Register DME type response + +**Data Producer rApp creates data offer** + +- 3 «R1» Create data offer request(info about data instance and delivery) +- 4 Create data offer and prepare delivery endpoint +- 5 «R1» Create data offer response (endpoint details for notify data availability or push data) + +**Data are collected from Data Producer rApp** + +**loop [data available]** + +**alt [pull delivery]** + +- 6 «R1» Notify data availability (pull details) +- 7 «R1» Pull data request +- 8 «R1» Pull data response (data) + +**[push delivery]** + +- 9 «R1» Push data (data) + +**10 Store data** + +**Data offer termination** + +**alt [Data Producer rApp terminates data offer]** + +- 11 «R1» Terminate data offer request +- 12 Delete data offer and stop collecting data +- 13 «R1» Terminate data offer response + +**[DME functions terminate data offer]** + +- 14 «R1» Notify data offer termination +- 15 Stop collecting data and terminate data offer + +**16 Stop producing data** + +Sequence diagram showing the interaction between Data Producer rApp and Non-RT RIC components (Data Management and Exposure functions, Data repository) for DME type registration, data offer creation, data collection, and data offer termination. + +**Figure 10.1.5-1: Example workflow using data offer procedures to trigger the collection and storage of data for later consumption** + +## 10.2 A1-related procedures + +### 10.2.1 EI results collection from rApps + +Figure 10.2.1-1 illustrates an example workflow of collecting data from rApps (over the R1 interface) that is delivered as EI job results to the Near-RT RICs (over the A1 interface). EI job results refer to the data being transferred from the Non-RT RIC to the Near-RT RICs, while EI source data refers to the data produced by the rApp that acts as the source for the data provided as EI job results. Correspondingly, EI type refers to the data type that is made available to the Near-RT RICs while the corresponding DME type registered by the rApp is referred to as EI source DME type. Moreover, EI job refers to a request for EI by the Near-RT RIC while EI source data subscription refers to the corresponding subscription to the rApp that acts the source for the data. + +NOTE 1: EI source data type refers to any DME type that is registered with the DME functions and the corresponding data are used as the source of EI job results. + +The rApp which generates the enrichment information first registers the EI source DME type in the DME functions. After successful DME type registration, the rApp registers the EI type for which it can produce enrichment information to the A1 enrichment information functions. In the registration request, the rApp should include the EI source DME type registered in the DME functions. The EI type is to be exposed via the A1 interface to the Near-RT RIC. The EI source DME type allows the A1 enrichment information functions to subscribe EI source data from DME functions. + +The A1 enrichment information functions query DME functions about the EI source DME type. If the query is successful, the EI type registered by the rApp is made available over the A1 interface. The Near-RT RIC queries available EI type identifiers in the Non-RT RIC. The Near-RT RIC queries EI type and creates an EI job via the A1 interface. After receiving the EI job creation request from the Near-RT RIC, the A1 enrichment information functions subscribe EI source data from DME functions. The DME functions further subscribe EI source data from the rApp over the R1 interface. + +Each time new EI source data are available, the rApp delivers EI source data to the DME functions using pull or push delivery. The DME functions deliver EI source data to the A1 enrichment information functions. The A1 enrichment formation functions establish the connection with Near-RT RIC and push the EI job results via the A1 interface. + +NOTE 2: SMO/Non-RT RIC framework internal interactions are not specified. + +NOTE 3: As an alternative to using the data subscription procedure, the data request procedure can be used to collect EI source data from the rApp. + +``` +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent +autonumber + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "rApp" as app + endbox + + box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "Data Management and Exposure functions" as dme + participant "A1 enrichment information functions" as eif + endbox +endbox + +Participant "Near-RT RIC" as ran + +group rApp register EI source DME type to DME functions +``` + +``` + +app -> dme : <> EI source DME type registration request +app <- dme : <> EI source DME type registration response +end + +group rApp register EI type +app -> eif : <> EI type registration request +app <- eif : <> EI type registration response +end + +group Al EI functions query EI source DME type from DME +eif --> dme : EI source DME type query request +eif <-- dme : EI source DME type query response +end + +group Query EI type identifiers +ran -> eif : <> EI type identifiers query request +ran <- eif : <> EI type identifiers query response +end + +group Query EI type +ran -> eif : <> EI type query request +ran <- eif : <> EI type query response +end + +group Create EI job +ran -> eif : <> EI job creation request +ran <- eif : <> EI job creation response +end + +group Al EI functions subscribe EI source data from DME +eif --> dme : EI source data subscription request +eif <-- dme : EI source data subscription response +end + +group DME functions subscribe EI source data from rApp +dme -> app : <> EI source data subscription request +dme <- app : <> EI source data subscription response +end + +loop EI source data available +alt pull delivery +app -> dme: <> Notify data availability (pull delivery details) +app <- dme: <> Pull data request +app -> dme: <> Pull data response (EI source data in payload) +else push delivery +app -> dme : <> Push data message (EI source data in payload) +end + +dme --> eif : EI source data delivery +group Deliver EI job results +eif -> ran : <> Push EI job results request +eif <- ran : <> Push EI job results response +end +end +@enduml + +``` + +![](f6ecf395a54b348ab80ec0c6f6ebbfec_img.jpg) + +**Non-RT RIC** + +**Non-anchored functions in SMO/Non-RT RIC FWK** + +Data Management and Exposure functions      A1 enrichment information functions + +**rApp**      **Near-RT RIC** + +**rApp register EI source DME type to DME functions** + +1 «R1» EI source DME type registration request +2 «R1» EI source DME type registration response + +**rApp register EI type** + +3 «R1» EI type registration request +4 «R1» EI type registration response + +**A1 EI functions query EI source DME type from DME** + +5 EI source DME type query request +6 EI source DME type query response + +**Query EI type identifiers** + +7 «A1» EI type identifiers query request +8 «A1» EI type identifiers query response + +**Query EI type** + +9 «A1» EI type query request +10 «A1» EI type query response + +**Create EI job** + +11 «A1» EI job creation request +12 «A1» EI job creation response + +**A1 EI functions subscribe EI source data from DME** + +13 EI source data subscription request +14 EI source data subscription response + +**DME functions subscribe EI source data from rApp** + +15 «R1» EI source data subscription request +16 «R1» EI source data subscription response + +**loop** [EI source data available] + +**alt** [pull delivery] + +17 «R1» Notify data availability (pull delivery details) +18 «R1» Pull data request +19 «R1» Pull data response (EI source data in payload) + +[push delivery] + +20 «R1» Push data message (EI source data in payload) + +21 EI source data delivery + +**Deliver EI job results** + +22 «A1» Push EI job results request +23 «A1» Push EI job results response + +**rApp**      Data Management and Exposure functions      A1 enrichment information functions      **Near-RT RIC** + +**Figure 10.2.1-1: Example workflow for EI results collection procedures** + +NOTE 4: A procedure for EI source data collection from external sources is not specified in the present document. + +### 10.2.2 rApp creating a policy with a Near-RT RIC identifier + +Figure 10.2.2-1 illustrates an example workflow of rApp creating a policy over the R1 interface with a Near-RT RIC identifier, and the Non-RT RIC creates the corresponding A1 policy at a Near-RT RIC over the A1 interface. In this example, it is assumed that the rApp obtained the Near-RT RIC identifier by consuming other R1 services. + +The rApp sends create policy request to the A1 policy functions in the SMO/Non-RT RIC framework, providing the policy object and a Near-RT RIC identifier. The A1 policy functions validate the creation request, e.g., whether the identified Near-RT RIC is operating, whether the rApp is authorized to create an A1 policy in the identified Near-RT RIC, whether the policy object provided in request is valid against the policy type schema, etc. + +If the validation fails, then A1 policy functions send the failure indication in the create policy response to rApp. Otherwise, the A1 policy functions generate an identifier for the policy and send a create A1 policy request to the target Near-RT RIC, including the policy identifier and the A1 policy object. + +If the Near-RT RIC indicates a successful creation in the create A1 policy response, the create policy response to the rApp over R1 carries the successful indication and the policy identifier. The rApp assumes that the policy is now enforced in the target Near-RT RIC. If the policy creation in A1 fails, then the Near-RT RIC sends proper error codes in the create A1 policy response. The A1 policy functions forward the failure indication to the rApp. + +``` +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent +autonumber + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "rApp" as app + endbox + + box "Non-anchored functions in \nSMO/Non-RT RIC FWK" #cadetBlue + participant "A1 Policy functions" as alp + endbox +endbox + +participant "Near-RT RIC" as ric + +app -> alp : <> Create policy request (Near-RT RIC id) +alp -> alp : Validate +alt Validation of the create policy request fails +app <- alp : <> Create policy response ("Fail") +else Validation of the create policy request is successful +alp -> alp : Generate policy id + +alp -> ric : <> Create A1 policy request (policy id) + +alt A1 policy creation is successful +alp <- ric : <> Create A1 policy response ("Success") +app <- alp : <> Create policy response (policy id, "Success") +else A1 policy creation is failed +alp <- ric : <> Create A1 policy response ("Fail") +app <- alp : <> Create policy response ("Fail") + +@enduml +``` + +![Sequence diagram showing the workflow of rApp creating a policy with a Near-RT RIC identifier. The diagram involves three main components: rApp, Non-RT RIC (containing A1 Policy functions), and Near-RT RIC. The process starts with rApp sending a 'Create policy request (Near-RT RIC id)' to A1 Policy functions. A1 Policy functions then validate the request. If validation fails, A1 Policy functions send a 'Create policy response (Fail)' back to rApp. If validation is successful, A1 Policy functions generate a policy id and send a 'Create A1 policy request (policy id)' to Near-RT RIC. Near-RT RIC then sends a 'Create A1 policy response (Success)' back to A1 Policy functions, which in turn sends a 'Create policy response (policy id, Success)' to rApp. If A1 policy creation fails, Near-RT RIC sends a 'Create A1 policy response (Fail)' back to A1 Policy functions, which then sends a 'Create policy response (Fail)' to rApp.](4cbfebc98185156dbae2b61dc16c051c_img.jpg) + +``` + +sequenceDiagram + participant rApp + participant Non-RT RIC + participant A1 as A1 Policy functions + participant Near-RT RIC + + Note over Non-RT RIC: Non-anchored functions in SMO/Non-RT RIC FWK + + rApp->>A1: 1 «R1» Create policy request (Near-RT RIC id) + A1->>A1: 2 Validate + alt [Validation of the create policy request fails] + A1-->>rApp: 3 «R1» Create policy response ("Fail") + else [Validation of the create policy request is successful] + A1->>A1: 4 Generate policy id + A1->>Near-RT RIC: 5 «A1» Create A1 policy request (policy id) + alt [A1 policy creation is successful] + Near-RT RIC-->>A1: 6 «A1» Create A1 policy response ("Success") + A1-->>rApp: 7 «R1» Create policy response (policy id, "Success") + else [A1 policy creation is failed] + Near-RT RIC-->>A1: 8 «A1» Create A1 policy response ("Fail") + A1-->>rApp: 9 «R1» Create policy response ("Fail") + end + end + +``` + +Sequence diagram showing the workflow of rApp creating a policy with a Near-RT RIC identifier. The diagram involves three main components: rApp, Non-RT RIC (containing A1 Policy functions), and Near-RT RIC. The process starts with rApp sending a 'Create policy request (Near-RT RIC id)' to A1 Policy functions. A1 Policy functions then validate the request. If validation fails, A1 Policy functions send a 'Create policy response (Fail)' back to rApp. If validation is successful, A1 Policy functions generate a policy id and send a 'Create A1 policy request (policy id)' to Near-RT RIC. Near-RT RIC then sends a 'Create A1 policy response (Success)' back to A1 Policy functions, which in turn sends a 'Create policy response (policy id, Success)' to rApp. If A1 policy creation fails, Near-RT RIC sends a 'Create A1 policy response (Fail)' back to A1 Policy functions, which then sends a 'Create policy response (Fail)' to rApp. + +Figure 10.2.2-1: Example workflow of rApp creating a policy with a Near-RT RIC identifier + +## 10.3 RAN OAM-related procedures + +### 10.3.1 Alarm query procedure + +Figure 10.3.1-1 illustrates an example workflow of querying alarm information. Alarm information from the nodes terminating the O1 interface is typically received by the SMO via O1. It is consolidated by the SMO/Non-RT RIC framework and can be queried by rApps via the R1 interface. + +NOTE: M-Plane alarms and slice alarms are not specified in the present document. + +``` + +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent +skinparam lifelineStrategy solid + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "rApp" as rapp + endbox +endbox + +``` + +``` + +box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "RAN OAM-related functions" as olrf +endbox +endbox +participant "Nodes terminating O1 interface" as me + +group SMO/Non-RT RIC FWK consolidates alarm information + alt Using alarm notifications + ref over olrf, me + 1 As specified in Clause 6.2.1.3 "Fault Notification - Procedures" + in O-RAN.WG10.01-Interface + end + else Using alarm list + ref over olrf, me + 2 As specified in Clause 6.2.2.3 "Fault Supervision Control - + Procedures" + in O-RAN.WG10.01-Interface + end + end + + autonumber 3 + olrf --> olrf: Consolidate alarm information +end + +rapp -> olrf: <> Query alarm information request(rApp identifier, filter criteria) +rapp <- olrf: <> Query alarm information response(alarm information) + +@enduml + +``` + +![Sequence diagram illustrating the alarm query workflow. The diagram shows three main components: rApp (yellow), Non-RT RIC (teal), and Nodes terminating O1 interface (light blue). The Non-RT RIC contains a sub-process 'Non-anchored functions in SMO/Non-RT RIC FWK' which further contains 'SMO/Non-RT RIC FWK consolidates alarm information'. This consolidation process has two alternative paths: '[Using alarm notifications]' (referring to Clause 6.2.1.3) and '[Using alarm list]' (referring to Clause 6.2.2.3). Step 3 shows 'Consolidate alarm information' within the Non-RT RIC. Step 4 shows a request from rApp to Non-RT RIC: '«R1» Query alarm information request(rApp identifier, filter criteria)'. Step 5 shows a response from Non-RT RIC to rApp: '«R1» Query alarm information response(alarm information)'.](bc6d103298fce2813b1c023dc1e3a5e9_img.jpg) + +Sequence diagram illustrating the alarm query workflow. The diagram shows three main components: rApp (yellow), Non-RT RIC (teal), and Nodes terminating O1 interface (light blue). The Non-RT RIC contains a sub-process 'Non-anchored functions in SMO/Non-RT RIC FWK' which further contains 'SMO/Non-RT RIC FWK consolidates alarm information'. This consolidation process has two alternative paths: '[Using alarm notifications]' (referring to Clause 6.2.1.3) and '[Using alarm list]' (referring to Clause 6.2.2.3). Step 3 shows 'Consolidate alarm information' within the Non-RT RIC. Step 4 shows a request from rApp to Non-RT RIC: '«R1» Query alarm information request(rApp identifier, filter criteria)'. Step 5 shows a response from Non-RT RIC to rApp: '«R1» Query alarm information response(alarm information)'. + +Figure 10.3.1-1: Example workflow of alarm query + +### 10.3.2 Change alarm acknowledgement state procedure + +Figure 10.3.2-1 illustrates an example workflow of changing the acknowledgement state of an alarm. Alarm information from the nodes terminating the O1 interface is typically received by the SMO via O1. It is consolidated by the SMO/Non-RT RIC framework. The rApps can change the acknowledgement state of the alarms that are known by the SMO/Non-RT RIC + +framework. Alarm acknowledgment state information is usually managed by the SMO/Non-RT RIC framework and is only passed to the radio nodes / Near-RT RIC if alarm acknowledgement / unacknowledgement is supported by these entities. + +NOTE: M-Plane alarms and slice alarms are not specified in the present document. + +``` +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent +skinparam lifelineStrategy solid + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "rApp" as rapp + endbox + + box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "RAN OAM-related functions" as olrf + endbox +endbox +participant "Nodes terminating O1 interface" as me + +group SMO/Non-RT RIC FWK consolidates alarm information + alt Using alarm notifications + ref over olrf, me + 1 As specified in Clause 6.2.1.3 "Fault Notification - Procedures" + in O-RAN.WG10.01-Interface + end + else Using alarm list + ref over olrf, me + 2 As specified in Clause 6.2.2.3 "Fault Supervision Control - Procedures" in O-RAN.WG10.01-Interface + end + end + + autonumber 3 + olrf --> olrf: Consolidate alarm information +end + +rapp -> olrf: <> Change alarm acknowledgement state request\n(rApp identifier, alarm identifier, new acknowledgment state) +olrf --> olrf: Store alarm acknowledgement state information +rapp <- olrf: <> Change alarm acknowledgement state response + +opt if alarm acknowledgement state change is supported by managed entity + ref over olrf, me + 7 Update alarm state as specified in Clause 6.2.2.3 + "Fault Supervision Control - Procedures" in O-RAN.WG10.01-Interface + end +end + +@enduml +``` + +![Sequence diagram showing the workflow of alarm acknowledgement state change. The diagram involves three main participants: rApp, Non-RT RIC, and Nodes terminating O1 interface. The Non-RT RIC participant contains nested boxes for 'Non-anchored functions in SMO/Non-RT RIC FWK' and 'RAN OAM-related functions'. The workflow starts with 'SMO/Non-RT RIC FWK consolidates alarm information', which branches into two paths: '[Using alarm notifications]' (referencing Clause 6.2.1.3) and '[Using alarm list]' (referencing Clause 6.2.2.3). Both paths lead to '3 Consolidate alarm information'. This is followed by '4 «R1» Change alarm acknowledgement state request (rApp identifier, alarm identifier, new acknowledgment state)' from rApp to Non-RT RIC, then '5 Store alarm acknowledgement state information' within Non-RT RIC, and finally '6 «R1» Change alarm acknowledgement state response' from Non-RT RIC to rApp. An optional path '[if alarm acknowledgement state change is supported by managed entity]' leads to '7 Update alarm state as specified in Clause 6.2.2.3 ](0637d3b96d4fa3f289ad92c7492070de_img.jpg) + +Sequence diagram showing the workflow of alarm acknowledgement state change. The diagram involves three main participants: rApp, Non-RT RIC, and Nodes terminating O1 interface. The Non-RT RIC participant contains nested boxes for 'Non-anchored functions in SMO/Non-RT RIC FWK' and 'RAN OAM-related functions'. The workflow starts with 'SMO/Non-RT RIC FWK consolidates alarm information', which branches into two paths: '[Using alarm notifications]' (referencing Clause 6.2.1.3) and '[Using alarm list]' (referencing Clause 6.2.2.3). Both paths lead to '3 Consolidate alarm information'. This is followed by '4 «R1» Change alarm acknowledgement state request (rApp identifier, alarm identifier, new acknowledgment state)' from rApp to Non-RT RIC, then '5 Store alarm acknowledgement state information' within Non-RT RIC, and finally '6 «R1» Change alarm acknowledgement state response' from Non-RT RIC to rApp. An optional path '[if alarm acknowledgement state change is supported by managed entity]' leads to '7 Update alarm state as specified in Clause 6.2.2.3 + +**Figure 10.3.2-1: Example workflow of alarm acknowledgement state change** + +### 10.3.3 Read configuration data procedure + +Figure 10.3.3-1 and figure 10.3.3-2 illustrate an example workflow of reading the current CM configurations of the network elements. CM configuration data from the RAN nodes terminating the O1 interface is typically received by the SMO via O1. It is cached and continuously synchronized by the SMO/Non-RT RIC framework (see figure 10.3.3-1) and can be retrieved by rApps via the R1 interface (see figure 10.3.3-2). The read configuration data request initiated by rApps may contain requests for reading configuration data for multiple RAN nodes in order to save bandwidth on the R1 interface. + +**NOTE:** Read configuration data procedure is defined in O-RAN R1GAP [9], clause 5.4.5. + +``` +@startuml +!pragma teoz true +skinparam ParticipantPadding 70 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +autonumber + +box "Non-RT RIC" #whitesmoke + box "Non-anchored functions in SMO/Non-RT RIC Framework" #cadetBlue + participant "RAN OAM-related functions" as fmSP + endbox +endbox +participant "Nodes terminating O1 interface" as dp +``` + +``` + +loop Synchronize configuration data with RAN nodes +alt + ref over fmsp,dp + As specified in Clause 6.1.5.3 + "Read Managed Object Instance Attributes - Procedures" + in O-RAN.WG10.01-Interface + end +else + ref over fmsp,dp + As specified in Clause 6.1.6.3 + "Notify Managed Object Instance Attributes - Procedures" + in O-RAN.WG10.01-Interface + end +end + +fmsp --> fmsp: Consolidate information +end + +@enduml + +``` + +![UML diagram showing the workflow for synchronizing configuration data in the SMO/Non-RT RIC framework with RAN nodes. The diagram is divided into two main sections: 'Non-RT RIC' (top) and 'Non-anchored functions in SMO/Non-RT RIC Framework' (bottom). The 'Non-RT RIC' section contains a 'loop' block labeled '[Synchronize configuration data with RAN nodes]'. Inside this loop is an 'alt' block with two 'ref' blocks. The first 'ref' block is labeled 'As specified in Clause 6.1.5.3' and 'Read Managed Object Instance Attributes - Procedures' in O-RAN.WG10.01-Interface. The second 'ref' block is labeled 'As specified in Clause 6.1.6.3' and 'Notify Managed Object Instance Attributes - Procedures' in O-RAN.WG10.01-Interface. Below the 'alt' block is a '1 Consolidate information' block with a dashed arrow pointing to the 'fmsp' block. The 'Non-anchored functions in SMO/Non-RT RIC Framework' section contains a 'RAN OAM-related functions' block. The diagram also shows 'Nodes terminating O1 interface' on the right side.](20a42da32eef641726c0d6215295102d_img.jpg) + +UML diagram showing the workflow for synchronizing configuration data in the SMO/Non-RT RIC framework with RAN nodes. The diagram is divided into two main sections: 'Non-RT RIC' (top) and 'Non-anchored functions in SMO/Non-RT RIC Framework' (bottom). The 'Non-RT RIC' section contains a 'loop' block labeled '[Synchronize configuration data with RAN nodes]'. Inside this loop is an 'alt' block with two 'ref' blocks. The first 'ref' block is labeled 'As specified in Clause 6.1.5.3' and 'Read Managed Object Instance Attributes - Procedures' in O-RAN.WG10.01-Interface. The second 'ref' block is labeled 'As specified in Clause 6.1.6.3' and 'Notify Managed Object Instance Attributes - Procedures' in O-RAN.WG10.01-Interface. Below the 'alt' block is a '1 Consolidate information' block with a dashed arrow pointing to the 'fmsp' block. The 'Non-anchored functions in SMO/Non-RT RIC Framework' section contains a 'RAN OAM-related functions' block. The diagram also shows 'Nodes terminating O1 interface' on the right side. + +**Figure 10.3.3-1: Example workflow for synchronizing configuration data in the SMO/Non-RT RIC framework with RAN nodes** + +``` + +@startuml +!pragma teoz true +skinparam ParticipantPadding 70 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "rApp" as rapp + endbox + + box "Non-anchored functions in SMO/Non-RT RIC Framework" #cadetBlue + participant "RAN OAM-related functions" as fmsp + endbox + +``` + +``` + +endbox +participant "Nodes terminating O1 interface" as dp +autonumber + +rapp -> fmsp: <> Request for reading configuration data (rAppId, queryCriteria) + +fmsp --> fmsp: Check if the requested data has been \n collected already and in sync with the RAN nodes + +opt if the requested data has not being collected yet or not in sync with the RAN nodes +ref over fmsp,dp + As specified in Clause 6.1.5.3 + "Read Managed Object Instance Attributes - Procedures" + in O-RAN.WG10.O1-Interface +end +end + +fmsp -> rapp: <> Read configuration data response +@enduml + +``` + +![Sequence diagram illustrating the read configuration data procedure. The diagram shows the interaction between an rApp, Non-RT RIC (Non-anchored functions in SMO/Non-RT RIC Framework), and Nodes terminating O1 interface. Step 1: rApp sends 'Request for reading configuration data (rAppId, queryCriteria)' to Non-RT RIC. Step 2: Non-RT RIC checks if the requested data has been collected already and is in sync with the RAN nodes. Step 3: If not collected or not in sync, Non-RT RIC initiates a read MOI attributes procedure (As specified in Clause 6.1.5.3 'Read Managed Object Instance Attributes - Procedures' in O-RAN.WG10.O1-Interface) with the Nodes terminating O1 interface. Finally, Non-RT RIC sends 'Read configuration data response ' to rApp.](fb4ad596448e423fe3ace53dc652a811_img.jpg) + +Sequence diagram illustrating the read configuration data procedure. The diagram shows the interaction between an rApp, Non-RT RIC (Non-anchored functions in SMO/Non-RT RIC Framework), and Nodes terminating O1 interface. Step 1: rApp sends 'Request for reading configuration data (rAppId, queryCriteria)' to Non-RT RIC. Step 2: Non-RT RIC checks if the requested data has been collected already and is in sync with the RAN nodes. Step 3: If not collected or not in sync, Non-RT RIC initiates a read MOI attributes procedure (As specified in Clause 6.1.5.3 'Read Managed Object Instance Attributes - Procedures' in O-RAN.WG10.O1-Interface) with the Nodes terminating O1 interface. Finally, Non-RT RIC sends 'Read configuration data response ' to rApp. + +**Figure 10.3.3-2: Example workflow for read configuration data procedure** + +The RAN OAM-related functions may maintain a local data store (implementation specific) caching part or all of the CM configurations of the RAN nodes for fast retrieval of configuration data from rApps and minimizing the signalling overhead on the O1 interface. In this example, as illustrated in figure 10.3.3-1, the RAN OAM-related functions synchronize the configuration data in its local data store with the RAN nodes continuously based on read MOI attributes procedures or notifications of MOI attribute changes over the O1 interface or internal knowledge of the attribute changes made by the rApps and framework functions within the SMO which is implementation specific. When the rApp initiates the read configuration data procedure, as illustrated in figure 10.3.3-2, the RAN OAM-related functions optionally check if the requested configuration data has been collected already and is up to date. The requested configuration data by the rApp might not be always cached in the local data store. If the requested data has not being collected, the RAN OAM-related functions initiate read MOI attributes procedures to collect the latest configuration data from the RAN nodes via the O1 interface as specified in O-RAN O1 interface [11], clause 6.1.5.3. Finally, a read configuration data response with the latest configuration data is sent to rApp by the RAN OAM-related functions. + +### 10.3.4 Write configuration changes procedure + +Figure 10.3.4-1 illustrates an example workflow of writing the CM configuration changes to the network elements. CM configurations in the RAN nodes terminating the O1 interface are typically managed by the SMO via O1. Configuration information is consolidated by the SMO/Non-RT RIC framework and can be modified by rApps via the R1 interface. The write configuration changes request initiated by rApps may contain bundled write requests for multiple RAN nodes in order to save bandwidth on the R1 interface. + +``` + +@startuml +!pragma teoz true +skinparam ParticipantPadding 70 +skinparam BoxPadding 10 + +``` + +``` + +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "rApp" as rapp + endbox + + box "Non-anchored functions in SMO/Non-RT RIC Framework" #cadetBlue + participant "RAN OAM-related functions" as fmsp + endbox +endbox +participant "Nodes terminating O1 interface" as dp +autonumber + +opt +rapp -> fmsp: <> Subscribe for write configuration job status notifications request +fmsp -> rapp: <> Subscribe for write configuration job status notifications response +end + +rapp -> fmsp: <> Request for writing configuration changes\n(rAppId, configuration changes +information) + +fmsp --> fmsp: AuthZ +fmsp --> fmsp: Validate request +fmsp --> fmsp: Store request + +fmsp -> rapp: <> Write configuration changes response (requestId) + +fmsp --> fmsp: Process request +ref over fmsp,dp + As specified in Clause 6.1.3.3 + "Modify Managed Object Instance Attributes - Procedures" + in O-RAN.WG10.01-Interface +end + +alt if subscribed +fmsp -> rapp: <> Write configuration changes job status notification \n(requestId, +configuration changes result) +else otherwise +rapp -> fmsp: <> Query write configuration job status (requestId) +fmsp -> rapp: <> Query write configuraiton job status reponse (configuration changes +result) +end + +@enduml + +``` + +![Sequence diagram showing the write configuration changes procedure. The diagram involves three main components: rApp (yellow), Non-RT RIC (teal), and Nodes terminating O1 interface (white). The Non-RT RIC contains 'Non-anchored functions in SMO/Non-RT RIC Framework' and 'RAN OAM-related functions'. The procedure starts with an optional step where rApp subscribes for write configuration job status notifications. Then, rApp sends a request for writing configuration changes. The Non-RT RIC performs internal steps: AuthZ, Validate request, Store request, and Process request. It then sends a response to rApp. A reference is made to Clause 6.1.3.3 'Modify Managed Object Instance Attributes - Procedures' in O-RAN.WG10.O1-Interface. An alternative path exists if the rApp is subscribed, where it receives a notification or queries the job status.](8fff37ade622ba5534e81b889a1cfdc5_img.jpg) + +``` + +sequenceDiagram + participant rApp + participant Non-RT RIC + participant Nodes as Nodes terminating O1 interface + + Note over Non-RT RIC: Non-anchored functions in SMO/Non-RT RIC Framework + Note over Non-RT RIC: RAN OAM-related functions + + opt opt + rApp->>Non-RT RIC: 1 «R1» Subscribe for write configuration job status notifications request + Non-RT RIC-->>rApp: 2 «R1» Subscribe for write configuration job status notifications response + end + + rApp->>Non-RT RIC: 3 «R1» Request for writing configuration changes (rAppId, configuration changes information) + + Note over Non-RT RIC: 4 AuthZ + Note over Non-RT RIC: 5 Validate request + Note over Non-RT RIC: 6 Store request + Note over Non-RT RIC: 8 Process request + + Non-RT RIC-->>rApp: 7 «R1» Write configuration changes response (requestId) + + Note over Non-RT RIC: ref + Note over Non-RT RIC: As specified in Clause 6.1.3.3 +"Modify Managed Object Instance Attributes - Procedures" +in O-RAN.WG10.O1-Interface + + alt alt [if subscribed] + Non-RT RIC-->>rApp: 9 «R1» Write configuration changes job status notification (requestId, configuration changes result) + else [otherwise] + rApp->>Non-RT RIC: 10 «R1» Query write configuration job status (requestId) + Non-RT RIC-->>rApp: 11 «R1» Query write configuration job status response (configuration changes result) + end + +``` + +Sequence diagram showing the write configuration changes procedure. The diagram involves three main components: rApp (yellow), Non-RT RIC (teal), and Nodes terminating O1 interface (white). The Non-RT RIC contains 'Non-anchored functions in SMO/Non-RT RIC Framework' and 'RAN OAM-related functions'. The procedure starts with an optional step where rApp subscribes for write configuration job status notifications. Then, rApp sends a request for writing configuration changes. The Non-RT RIC performs internal steps: AuthZ, Validate request, Store request, and Process request. It then sends a response to rApp. A reference is made to Clause 6.1.3.3 'Modify Managed Object Instance Attributes - Procedures' in O-RAN.WG10.O1-Interface. An alternative path exists if the rApp is subscribed, where it receives a notification or queries the job status. + +**Figure 10.3.4-1: Example workflow for write configuration changes procedure** + +The write configuration changes request is handled in asynchronous approach. When the rApp initiates the write configuration changes procedure, the RAN OAM-related functions authenticate the request with SME, validate the request, store the request as job and acknowledge the request by sending write configuration changes response indicating that the request has been accepted for processing, but the processing job has not been completed. An assigned requested identifying the created processing job is included in the response. The actual processing job for the write configuration changes request which includes e.g., conflict detection, conflict mitigation and writing the configuration changes to each RAN node as requested via the O1 interface, happens asynchronously. If the rApp has subscribed for the notification of the write configuration changes job status, the RAN OAM-related functions send a notification to the rApp once the write configuration changes job is complete, indicating the completion of the job and providing information about success, partial success, or failure result with failure reasons. Otherwise, the rApp can query for the write configuration changes job status and result with query procedures. + +## 10.4 AI/ML workflow procedures + +### 10.4.1 rApps register, discover AI/ML models, and subscribe to models changes + +Figure 10.4.1-1 illustrates an example workflow of rApps using AI/ML workflow functions to register, discover AI/ML models and subscribe to registered models changes. + +A model producer rApp sends a request to the AI/ML workflow functions to register an AI/ML model. The register AI/ML model request contains AI/ML model information (e.g., model accuracy, model usage scenario, model training dataset information, etc.). Upon receipt of the registration request, the AI/ML workflow functions authorize the model producer rApp and register the AI/ML model. After successful registration, the AI/ML workflow functions assign an AI/ML model registration identifier and communicate this registration identifier to the model producer rApp in a register AI/ML model response. + +A model consumer rApp sends a request to the AI/ML workflow functions to discover registered AI/ML models based on optional selection criteria. After receiving the request, the AI/ML workflow functions authorize the model consumer rApp and + +communicate to the model consumer rApp the model identifier(s) and metadata of AI/ML model(s) that match the provided selection criteria. + +The model consumer rApp can send a subscribe AI/ML model change request to the AI/ML workflow functions to subscribe to the changes in a registered AI/ML model. Upon receipt of the subscription request, AI/ML workflow functions authorize the model consumer rApp and create a subscription. After successful subscription, the AI/ML workflow functions communicate to the model consumer rApp the subscription ID in a subscribe AI/ML model change response. + +When there is a change in the subscribed AI/ML model, the AI/ML workflow functions send notifications of changes in the registered AI/ML model to the subscribed AI/ML model consumer rApp. + +When the model producer rApp sends a deregister request to the AI/ML workflow functions to deregister a registered AI/ML model, the AI/ML workflow functions deregister the AI/ML model and communicate to the rApp that the deregistration was successful. The AI/ML workflow functions send notifications of the deregistration of the registered AI/ML model to the subscribed AI/ML model consumer rApp. + +The model consumer rApp can send an unsubscribe request to the AI/ML workflow functions to unsubscribe to changes in a registered AI/ML model. Upon reception of the unsubscribe request, the AI/ML workflow functions unsubscribe the model consumer rApp to the AI/ML model change. After successfully unsubscribing, the AI/ML workflow functions communicate to the model consumer rApp that unsubscribing was successful. + +``` +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent +autonumber + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "Model Consumer rApp" as rApp + endbox + + box " Non-anchored functions in SMO/Non-RT RIC Framework " #cadetBlue + participant "AI/ML workflow functions" as ML + endbox + + box #ivory + participant "Model Producer rApp" as src + endbox + endbox + +group Model Producer rApp register model +src -> ML: <> Register AI/ML model request (rAppID, AI/ML model information) +ML -> ML: Authz +ML -> ML: register AI/ML model +ML -> src: <> Register AI/ML model response (AI/ML model registration identifier) +end + +group Model Consumer rApp discover model +rApp -> ML: <> Discover AI/ML model request (rAppID, selection criteria) +ML -> ML: Authz +ML -> rApp: <> Discover AI/ML model response (AI/ML model identifier(s) and metadata) +end + +group Model Consumer rApp subscribe model change +rApp -> ML: <> Subscribe AI/ML model change request (rAppID, AI/ML model identifier(s)) +ML -> ML: Create subscription +ML -> rApp: <> Subscribe AI/ML model change response (subscription ID) +end + +group The subscribed model has been changed +``` + +``` + +ML -> rApp: <> Notify AI/ML model changes (subscription ID, AI/ML model identifier, +available change details) +end + +group The subscribed model has been deregistered +group Model Producer rApp deregister model +src -> ML: <> Deregister AI/ML model (rAppID, AI/ML model registration identifier) +ML -> ML: Deregister AI/ML model +ML -> src: <> Deregister AI/ML model response +end +ML -> rApp: <> Notify AI/ML model deregistration (subscription ID, AI/ML model identifier) +end + +group Model Consumer rApp unsubscribe model change +rApp -> ML: <> Unsubscribe AI/ML model change request (rAppID, subscription ID) +ML -> ML: Unsubscription model change +ML -> rApp: <> Unsubscribe AI/ML model change response +end +@enduml + +``` + +![Sequence diagram showing the workflow of AI/ML model registration, discovery, and subscription to a registered AI/ML model changes. The diagram involves three main entities: Model Consumer rApp, Non-RT RIC (containing AI/ML workflow functions and Non-anchored functions in SMO/Non-RT RIC Framework), and Model Producer rApp. The workflow includes steps for registering, discovering, subscribing to, and deregistering models, with corresponding messages and responses.](342ac84634b673b0a0234f1f312cfd61_img.jpg) + +``` + +sequenceDiagram + participant MCR as Model Consumer rApp + participant NRT as Non-RT RIC + participant MP as Model Producer rApp + + Note over NRT: Non-anchored functions in SMO/Non-RT RIC Framework + Note over NRT: AI/ML workflow functions + + MCR->>NRT: 1 «R1» Register AI/ML model request (rAppID, AI/ML model information) + NRT->>MP: 2 Authz + MP-->>NRT: 3 register AI/ML model + NRT->>MCR: 4 «R1» Register AI/ML model response (AI/ML model registration identifier) + + MCR->>NRT: 5 «R1» Discover AI/ML model request (rAppID, selection criteria) + NRT->>MP: 6 Authz + MP-->>NRT: 7 «R1» Discover AI/ML model response (AI/ML model identifier(s) and metadata) + + MCR->>NRT: 8 «R1» Subscribe AI/ML model change request (rAppID, AI/ML model identifier(s)) + NRT->>MP: 9 Create subscription + MP-->>NRT: 10 «R1» Subscribe AI/ML model change response (subscription ID) + + Note over MCR: The subscribed model has been changed + MCR->>NRT: 11 «R1» Notify AI/ML model changes (subscription ID, AI/ML model identifier, available change details) + + Note over MCR: The subscribed model has been deregistered + MCR->>NRT: 12 «R1» Deregister AI/ML model (rAppID, AI/ML model registration identifier) + NRT->>MP: 13 Deregister AI/ML model + MP-->>NRT: 14 «R1» Deregister AI/ML model response + NRT->>MCR: 15 «R1» Notify AI/ML model deregistration (subscription ID, AI/ML model identifier) + + MCR->>NRT: 16 «R1» Unsubscribe AI/ML model change request (rAppID, subscription ID) + NRT->>MP: 17 Unsubscription model change + MP-->>NRT: 18 «R1» Unsubscribe AI/ML model change response + +``` + +Sequence diagram showing the workflow of AI/ML model registration, discovery, and subscription to a registered AI/ML model changes. The diagram involves three main entities: Model Consumer rApp, Non-RT RIC (containing AI/ML workflow functions and Non-anchored functions in SMO/Non-RT RIC Framework), and Model Producer rApp. The workflow includes steps for registering, discovering, subscribing to, and deregistering models, with corresponding messages and responses. + +**Figure 10.4.1-1: Example workflow of AI/ML model registration, discovery, and subscription to a registered AI/ML model changes** + +NOTE: The metadata includes model related information, e.g., training dataset information, etc. + +### 10.4.2 AI/ML training procedures + +The following figures illustrate an example workflows of an AI/ML training services Consumer rApp requesting AI/ML training of an AI/ML model. In figure 10.4.2-1, the AI/ML workflow functions in the Non-RT RIC framework are the AI/ML training services Producer. In figure 10.4.2-2, an AI/ML training services Producer rApp produces the AI/ML training services. In figure 10.4.2-3, the AI/ML workflow functions coordinate AI/ML training in the SMO/Non-RT RIC, and they relay training request and subsequent messages between the AI/ML training services Consumer App and a proper AI/ML training services Producer rApp based on registered training capabilities. + +The AI/ML training services Consumer rApp sends a training request to the AI/ML training services Producer, providing model identifier of the model to be trained, information about required data for training, training requirements such as validation criteria, and a URI to receive notifications, etc. The AI/ML training services Producer, if accepts the training request, sends back request training response containing a training identifier. + +After accepting the training request, the AI/ML training services Producer may retrieve the model from the model repository and consumes training data via DME based on the information provided by the AI/ML training services Consumer rApp. The AI/ML training services Producer then performs the training. + +The AI/ML training services Consumer rApp can query the training job status using the received training job identifier. The AI/ML training services Producer provides the training job status in the response to the query. + +If the AI/ML training services Consumer rApp wants to cancel the on-going training, it sends a cancel training request to the AI/ML training services Producer providing the training job identifier. The AI/ML training services Producer then terminates the training and response to the AI/ML training services Consumer rApp. + +If the training completes, the AI/ML training services Producer may store the trained model in the model repository, and it then notifies the AI/ML training services Consumer rApp about the completion of the training, sending the notification to the notification URI received in the training request. + +The AI/ML training services Consumer rApp can retrieve the trained model from the model repository, if the AI/ML training services Producer has stored the trained model in the model repository. + +NOTE: The model repository can be implemented as part of the AI/ML workflow functions. + +``` +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "AI/ML training services \n Consumer rApp" as con + endbox + + box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "AI/ML workflow functions" as aif + participant "DME functions" as dme + database "Model repository" as rep + endbox +endbox + +autonumber +con -> aif: <> Request training request \n (model id, required data, validation criteria, +notification URI, etc.) +con <- aif: <> Request training response (training job id) + +rnote over aif, rep +Retrieve model (optional) +``` + +``` +end note + +rnote over aif, dme +Data consumption for training data +end note + +rnote over aif +Perform training +end note + +con -> aif: <> Query training job status request (training job id) +con <- aif: <> Query training job status response (training job status) + +alt AI/ML training services Consumer cancels training +con -> aif: <> Cancel training request (training job id) +rnote over aif +Terminate training +end note +con <- aif: <> Cancel training response +else AI/ML training services Producer completes training +rnote over aif +Training completed +end note + +rnote over aif, rep +Store model (optional) +end note + +con <- aif: <> Training job status notification \n (training job id, model id, training +job status: "Completed") +end +@enduml +``` + +![Sequence diagram showing the workflow of AI/ML training. The diagram is divided into two main sections: 'Non-RT RIC' and 'Non-anchored functions in SMO/Non-RT RIC FWK'. The 'Non-RT RIC' section contains two lifelines: 'AI/ML training services Consumer rApp' and 'AI/ML training services Producer rApp'. The 'Non-anchored functions in SMO/Non-RT RIC FWK' section contains three lifelines: 'AI/ML workflow functions', 'DME functions', and 'Model repository'. The workflow starts with the Consumer rApp sending a 'Request training request' (1) to the AI/ML workflow functions. The AI/ML workflow functions then send a 'Request training response' (2) back to the Consumer rApp. The AI/ML workflow functions then perform 'Retrieve model (optional)', 'Data consumption for training data', and 'Perform training'. The AI/ML workflow functions then send a 'Query training job status request' (3) to the DME functions. The DME functions then send a 'Query training job status response' (4) back to the AI/ML workflow functions. An alternative path is shown where the Consumer rApp sends a 'Cancel training request' (5) to the AI/ML workflow functions, which then perform 'Terminate training' and send a 'Cancel training response' (6) back to the Consumer rApp. The AI/ML workflow functions then send a 'Training job status notification' (7) to the Producer rApp. The Producer rApp then performs 'Training completed' and 'Store model (optional)'. The Model repository is also shown as a database component.](1ff1acedf67b83f08dfb68ced8fe0a24_img.jpg) + +``` + +sequenceDiagram + participant Consumer as AI/ML training services Consumer rApp + participant AIWorkflow as AI/ML workflow functions + participant DME as DME functions + participant ModelRepo as Model repository + + Note over AIWorkflow, DME, ModelRepo: Non-anchored functions in SMO/Non-RT RIC FWK + + Consumer->>AIWorkflow: 1 «R1» Request training request (model id, required data, validation criteria, notification URI, etc.) + AIWorkflow-->>Consumer: 2 «R1» Request training response (training job id) + + Note over AIWorkflow, DME, ModelRepo: Retrieve model (optional) + Note over AIWorkflow, DME, ModelRepo: Data consumption for training data + Note over AIWorkflow, DME, ModelRepo: Perform training + + AIWorkflow->>DME: 3 «R1» Query training job status request (training job id) + DME-->>AIWorkflow: 4 «R1» Query training job status response (training job status) + + alt [AI/ML training services Consumer cancels training] + AIWorkflow->>Consumer: 5 «R1» Cancel training request (training job id) + Note over AIWorkflow, DME, ModelRepo: Terminate training + DME-->>AIWorkflow: 6 «R1» Cancel training response + end + + Note over AIWorkflow, DME, ModelRepo: Training completed + Note over AIWorkflow, DME, ModelRepo: Store model (optional) + + AIWorkflow->>Producer as AI/ML training services Producer rApp: 7 «R1» Training job status notification (training job id, model id, training job status: "Completed") + Note over AIWorkflow, DME, ModelRepo: Training completed + Note over AIWorkflow, DME, ModelRepo: Store model (optional) + +``` + +Sequence diagram showing the workflow of AI/ML training. The diagram is divided into two main sections: 'Non-RT RIC' and 'Non-anchored functions in SMO/Non-RT RIC FWK'. The 'Non-RT RIC' section contains two lifelines: 'AI/ML training services Consumer rApp' and 'AI/ML training services Producer rApp'. The 'Non-anchored functions in SMO/Non-RT RIC FWK' section contains three lifelines: 'AI/ML workflow functions', 'DME functions', and 'Model repository'. The workflow starts with the Consumer rApp sending a 'Request training request' (1) to the AI/ML workflow functions. The AI/ML workflow functions then send a 'Request training response' (2) back to the Consumer rApp. The AI/ML workflow functions then perform 'Retrieve model (optional)', 'Data consumption for training data', and 'Perform training'. The AI/ML workflow functions then send a 'Query training job status request' (3) to the DME functions. The DME functions then send a 'Query training job status response' (4) back to the AI/ML workflow functions. An alternative path is shown where the Consumer rApp sends a 'Cancel training request' (5) to the AI/ML workflow functions, which then perform 'Terminate training' and send a 'Cancel training response' (6) back to the Consumer rApp. The AI/ML workflow functions then send a 'Training job status notification' (7) to the Producer rApp. The Producer rApp then performs 'Training completed' and 'Store model (optional)'. The Model repository is also shown as a database component. + +**Figure 10.4.2-1: Example workflow of AI/ML training: AI/ML workflow functions act as the training service Producer** + +``` + +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "AI/ML training services \n Consumer rApp" as con + participant "AI/ML training services \n Producer rApp" as pro + endbox + + box "Non-anchored functions in \n SMO/Non-RT RIC FWK" #cadetBlue + participant "DME functions" as dme + database "Model repository" as rep + endbox + +``` + +``` + +endbox + +autonumber +con -> pro: Request training request \n (model id, required data, \n validation criteria, +notification URI, etc.) +con <- pro: Request training response (training job id) + +rnote over pro, rep +<> Retrieve model (optional) +end note + +rnote over pro, dme +<> Data consumption for training data +end note + +rnote over pro +Perform training +end note + +con -> pro: Query training job status request (training job id) +con <- pro: Query training job status response (training job status) + +alt AI/ML training services Consumer cancels training +con -> pro: Cancel training request (training job id) +rnote over pro +Terminate training +end note +con <- pro: Cancel training response +else AI/ML training services Producer completes training +rnote over pro +Training completed +end note +rnote over pro, rep +<> Store model (optional) +end note +con <- pro: Training job status notification \n (training job id, model id, training job +status: "Completed") +end +@enduml + +``` + +![Sequence diagram showing the workflow of AI/ML training. The diagram is divided into two main sections: 'Non-RT RIC' and 'Non-anchored functions in SMO/Non-RT RIC FWK'. In the 'Non-RT RIC' section, there are two lifelines: 'AI/ML training services Consumer rApp' and 'AI/ML training services Producer rApp'. The workflow starts with the Consumer rApp sending a 'Request training request' (1) to the Producer rApp. The Producer rApp responds with a 'Request training response (training job id)' (2). The Producer rApp then performs 'Perform training'. The Consumer rApp sends a 'Query training job status request (training job id)' (3) to the Producer rApp, which responds with a 'Query training job status response (training job status)' (4). An 'alt' block contains two paths: one for '[AI/ML training services Consumer cancels training]' where the Consumer rApp sends a 'Cancel training request (training job id)' (5) and the Producer rApp responds with a 'Cancel training response' (6); and another for '[AI/ML training services Producer completes training]' where the Producer rApp sends a 'Training job status notification (training job id, model id, training job status: "Completed")' (7). In the 'Non-anchored functions in SMO/Non-RT RIC FWK' section, there are two lifelines: 'DME functions' and 'Model repository'. The Producer rApp interacts with the Model repository to 'Retrieve model (optional)' (R1) and 'Data consumption for training data'. The Producer rApp also interacts with the DME functions to 'Store model (optional)' (R1).](a4cd4074d265ca65a54ff2a58c6c379a_img.jpg) + +Sequence diagram showing the workflow of AI/ML training. The diagram is divided into two main sections: 'Non-RT RIC' and 'Non-anchored functions in SMO/Non-RT RIC FWK'. In the 'Non-RT RIC' section, there are two lifelines: 'AI/ML training services Consumer rApp' and 'AI/ML training services Producer rApp'. The workflow starts with the Consumer rApp sending a 'Request training request' (1) to the Producer rApp. The Producer rApp responds with a 'Request training response (training job id)' (2). The Producer rApp then performs 'Perform training'. The Consumer rApp sends a 'Query training job status request (training job id)' (3) to the Producer rApp, which responds with a 'Query training job status response (training job status)' (4). An 'alt' block contains two paths: one for '[AI/ML training services Consumer cancels training]' where the Consumer rApp sends a 'Cancel training request (training job id)' (5) and the Producer rApp responds with a 'Cancel training response' (6); and another for '[AI/ML training services Producer completes training]' where the Producer rApp sends a 'Training job status notification (training job id, model id, training job status: "Completed")' (7). In the 'Non-anchored functions in SMO/Non-RT RIC FWK' section, there are two lifelines: 'DME functions' and 'Model repository'. The Producer rApp interacts with the Model repository to 'Retrieve model (optional)' (R1) and 'Data consumption for training data'. The Producer rApp also interacts with the DME functions to 'Store model (optional)' (R1). + +**Figure 10.4.2-2: Example workflow of AI/ML training: AI/ML training services Producer rApp acts as the AI/ML training services Producer** + +``` +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "AI/ML training services \n Consumer rApp" as con + participant "AI/ML training services \n Producer rApp" as pro + endbox + + box "Non-anchored functions in SMO/Non-RT RIC FWK" #cadetBlue + participant "AI/ML workflow functions" as aif + endbox + +``` + +``` + + participant "DME functions" as dme + database "Model repository" as rep +endbox +endbox +autonumber +con -> aif: <> Request training request \n (model id, required data, validation criteria, +notification URI, etc.) +aif --> aif: Identify proper training \n service Producer rApp +pro <- aif: <> Request training request \n (model id, required data, \n validation +criteria, notification URI, etc.) +pro -> aif: <> Request training response \n (training job id) +con <- aif: <> Request training response (training job id) + +rnote over pro, rep +<> Retrieve model (optional) +end note + +rnote over pro, dme +<> Data consumption for training data +end note + +rnote over pro +Perform training +end note + +con -> aif: <> Query training job status request (training job id) +pro <- aif: <> Query training job status request \n (training job id) +pro -> aif: <> Query training job status response \n (training job status) +con <- aif: <> Query training job status response (training job status) + +alt AI/ML training services Consumer cancels training +con -> aif: <> Cancel training request (training job id) +pro <- aif: <> Cancel training request \n (training job id) +rnote over pro +Terminate training +end note +pro -> aif: <> Cancel training response +con <- aif: <> Cancel training response +else AI/ML training services Producer completes training +rnote over pro +Training completed +end note + +rnote over pro, rep +<> Store model (optional) +end note +pro -> aif: <> Training job status notification \n (training job id, model id, \n training +job status: "Completed") +con <- aif: <> Training job status notification \n (training job id, model id, training +job status: "Completed") +end +@enduml + +``` + +![Sequence diagram showing the workflow of AI/ML training. The diagram is divided into two main sections: 'Non-RT RIC' and 'Non-anchored functions in SMO/Non-RT RIC FWK'. The 'Non-RT RIC' section contains two lifelines: 'AI/ML training services Consumer rApp' and 'AI/ML training services Producer rApp'. The 'Non-anchored functions in SMO/Non-RT RIC FWK' section contains three lifelines: 'AI/ML workflow functions', 'DME functions', and 'Model repository'. The workflow starts with the Consumer rApp sending a 'Request training request' (1) to the AI/ML workflow functions. The AI/ML workflow functions then identify a proper training service Producer rApp (2). The Consumer rApp sends a 'Request training request' (3) to the AI/ML workflow functions, which then sends a 'Request training response' (4) to the Producer rApp. The Producer rApp sends a 'Request training response' (5) to the AI/ML workflow functions. The AI/ML workflow functions then retrieve the model (optional) and consume data for training. The Producer rApp performs training and sends a 'Query training job status request' (6) to the AI/ML workflow functions. The AI/ML workflow functions then send a 'Query training job status request' (7) to the Producer rApp, which responds with a 'Query training job status response' (8). The AI/ML workflow functions then send a 'Query training job status response' (9) to the Consumer rApp. An alternative path is shown for when the Consumer rApp cancels training: it sends a 'Cancel training request' (10) to the AI/ML workflow functions, which then sends a 'Cancel training request' (11) to the Producer rApp. The Producer rApp terminates training and sends a 'Cancel training response' (12) to the AI/ML workflow functions, which then sends a 'Cancel training response' (13) to the Consumer rApp. Another path is shown for when the Producer rApp completes training: it sends a 'Training completed' notification to the AI/ML workflow functions, which then stores the model (optional) and sends a 'Training job status notification' (14) to the Producer rApp. The AI/ML workflow functions then send a 'Training job status notification' (15) to the Consumer rApp.](4c1d36e7e9b1afb90721dcc9fb45a557_img.jpg) + +**Non-RT RIC** + +**Non-anchored functions in SMO/Non-RT RIC FWK** + +AI/ML training services Consumer rApp, AI/ML training services Producer rApp, AI/ML workflow functions, DME functions, Model repository + +1 «R1» Request training request (model id, required data, validation criteria, notification URI, etc.) + +2 Identify proper training service Producer rApp + +3 «R1» Request training request (model id, required data, validation criteria, notification URI, etc.) + +4 «R1» Request training response (training job id) + +5 «R1» Request training response (training job id) + +«R1» Retrieve model (optional) + +«R1» Data consumption for training data + +Perform training + +6 «R1» Query training job status request (training job id) + +7 «R1» Query training job status request (training job id) + +8 «R1» Query training job status response (training job status) + +9 «R1» Query training job status response (training job status) + +**alt [AI/ML training services Consumer cancels training]** + +10 «R1» Cancel training request (training job id) + +11 «R1» Cancel training request (training job id) + +Terminate training + +12 «R1» Cancel training response + +13 «R1» Cancel training response + +**[AI/ML training services Producer completes training]** + +Training completed + +«R1» Store model (optional) + +14 «R1» Training job status notification (training job id, model id, training job status: "Completed") + +15 «R1» Training job status notification (training job id, model id, training job status: "Completed") + +AI/ML training services Consumer rApp, AI/ML training services Producer rApp, AI/ML workflow functions, DME functions, Model repository + +Sequence diagram showing the workflow of AI/ML training. The diagram is divided into two main sections: 'Non-RT RIC' and 'Non-anchored functions in SMO/Non-RT RIC FWK'. The 'Non-RT RIC' section contains two lifelines: 'AI/ML training services Consumer rApp' and 'AI/ML training services Producer rApp'. The 'Non-anchored functions in SMO/Non-RT RIC FWK' section contains three lifelines: 'AI/ML workflow functions', 'DME functions', and 'Model repository'. The workflow starts with the Consumer rApp sending a 'Request training request' (1) to the AI/ML workflow functions. The AI/ML workflow functions then identify a proper training service Producer rApp (2). The Consumer rApp sends a 'Request training request' (3) to the AI/ML workflow functions, which then sends a 'Request training response' (4) to the Producer rApp. The Producer rApp sends a 'Request training response' (5) to the AI/ML workflow functions. The AI/ML workflow functions then retrieve the model (optional) and consume data for training. The Producer rApp performs training and sends a 'Query training job status request' (6) to the AI/ML workflow functions. The AI/ML workflow functions then send a 'Query training job status request' (7) to the Producer rApp, which responds with a 'Query training job status response' (8). The AI/ML workflow functions then send a 'Query training job status response' (9) to the Consumer rApp. An alternative path is shown for when the Consumer rApp cancels training: it sends a 'Cancel training request' (10) to the AI/ML workflow functions, which then sends a 'Cancel training request' (11) to the Producer rApp. The Producer rApp terminates training and sends a 'Cancel training response' (12) to the AI/ML workflow functions, which then sends a 'Cancel training response' (13) to the Consumer rApp. Another path is shown for when the Producer rApp completes training: it sends a 'Training completed' notification to the AI/ML workflow functions, which then stores the model (optional) and sends a 'Training job status notification' (14) to the Producer rApp. The AI/ML workflow functions then send a 'Training job status notification' (15) to the Consumer rApp. + +Figure 10.4.2-3: Example workflow of AI/ML training: AI/ML workflow functions coordinate AI/ML training + +### 10.4.3 AI/ML model storage and retrieval procedures + +Figure 10.4.3-1 illustrates an example workflow of AI/ML model storage and retrieval. + +The AI/ML training services Consumer rApp sends training request to the AI/ML training services Producer rApp. After accepting the training request, the AI/ML training services Producer rApp may send a retrieve model request to the AI/ML workflow functions, containing the model identifier of the AI/ML model to be trained. The AI/ML workflow functions validate the retrieval request and provide the model location details of the requested AI/ML model. The AI/ML training services Producer rApp may retrieve the model to be trained via the model location details. + +The AI/ML training services Producer rApp trains the AI/ML model. After the completion of the model training, the AI/ML training services Producer rApp may send store model request to the AI/ML workflow functions to store the trained model. It provides the model identifier and model location details for the trained model in the request. The AI/ML workflow functions response to the storage request with an updated identifier for the trained model. + +The AI/ML training services Producer rApp notifies the AI/ML training services Consumer rApp about the completion of the model training. The AI/ML training services Consumer rApp then may send retrieve model request to the AI/ML workflow functions with the updated model identifier to retrieve the trained model. The AI/ML workflow functions response to the retrieval request with the model location details of the trained model. + +``` +@startuml +!pragma teoz true +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +skinparam defaultFontSize 12 +skinparam lifelineStrategy solid +skinparam SequenceGroupBackgroundColor Transparent +skinparam SequenceGroupBodyBackgroundColor Transparent + +box "Non-RT RIC" #whitesmoke + box #ivory + participant "AI/ML Training service \n Consumer rApp" as con + participant "AI/ML Training service \n Producer rApp" as pro + endbox + + box "Non-anchored functions \n in SMO/Non-RT RIC FWK" #cadetBlue + participant "AI/ML workflow functions" as aif + endbox +endbox + +autonumber +con -> pro: request training request \n (model id, required data, \n validation criteria, +notification URI, etc.) +con <- pro: request training response \n (training job id) + +opt + pro -> aif: <> retrieve model request \n (rApp id, model id) + pro <- aif: <> retrieve model response \n (model location details) +end + +note over pro + Train AI/ML model +end note + +opt + pro -> aif: <> store model request \n (rApp id, model id, \n model location details) + pro <- aif: <> store model response \n (updated model id) +end + +con <- pro: Notify training complete \n (training job id, training job status, \n updated +model id) +opt + con -> aif: <> retrieve model request (rApp id, updated model id) + con <- aif: <> retrieve model response (model location details) +end +``` + +@endum1 + +![Sequence diagram showing the workflow of AI/ML model storage and retrieval between Non-RT RIC and Non-anchored functions in SMO/Non-RT RIC FWK.](53a35ae4b6173e48c9fb0b085b6b0f69_img.jpg) + +``` + +sequenceDiagram + participant Non-RT_RIC as Non-RT RIC + participant Non_anchored as Non-anchored functions in SMO/Non-RT RIC FWK + + Note over Non-RT_RIC: AI/ML Training service Consumer rApp + Note over Non-RT_RIC: AI/ML Training service Producer rApp + Note over Non_anchored: AI/ML workflow functions + + Non-RT_RIC->>Non-RT_RIC: 1 request training request (model id, required data, validation criteria, notification URI, etc.) + Non-RT_RIC->>Non-RT_RIC: 2 request training response (training job id) + + Note over Non-RT_RIC: opt + Non-RT_RIC->>Non_anchored: 3 «R1» retrieve model request (rApp id, model id) + Non_anchored-->>Non-RT_RIC: 4 «R1» retrieve model response (model location details) + + Note over Non-RT_RIC: Train AI/ML model + + Note over Non-RT_RIC: opt + Non-RT_RIC->>Non_anchored: 5 «R1» store model request (rApp id, model id, model location details) + Non_anchored-->>Non-RT_RIC: 6 «R1» store model response (updated model id) + + Non-RT_RIC->>Non-RT_RIC: 7 Notify training complete (training job id, training job status, updated model id) + + Note over Non-RT_RIC: opt + Non-RT_RIC->>Non_anchored: 8 «R1» retrieve model request (rApp id, updated model id) + Non_anchored-->>Non-RT_RIC: 9 «R1» retrieve model response (model location details) + + Note over Non-RT_RIC: AI/ML Training service Consumer rApp + Note over Non-RT_RIC: AI/ML Training service Producer rApp + Note over Non_anchored: AI/ML workflow functions + +``` + +The diagram illustrates the workflow of AI/ML model storage and retrieval. It is divided into two main sections: Non-RT RIC and Non-anchored functions in SMO/Non-RT RIC FWK. The Non-RT RIC section contains two lifelines: AI/ML Training service Consumer rApp and AI/ML Training service Producer rApp. The Non-anchored functions section contains one lifeline: AI/ML workflow functions. The workflow consists of the following steps: + +- request training request** (model id, required data, validation criteria, notification URI, etc.) from Consumer to Producer. +- request training response** (training job id) from Producer to Consumer. +- «R1» retrieve model request** (rApp id, model id) from Consumer to Non-anchored functions (optional). +- «R1» retrieve model response** (model location details) from Non-anchored functions to Consumer (optional). +- Train AI/ML model** (local action on Producer). +- «R1» store model request** (rApp id, model id, model location details) from Consumer to Non-anchored functions (optional). +- «R1» store model response** (updated model id) from Non-anchored functions to Consumer (optional). +- Notify training complete** (training job id, training job status, updated model id) from Producer to Consumer. +- «R1» retrieve model request** (rApp id, updated model id) from Consumer to Non-anchored functions (optional). +- «R1» retrieve model response** (model location details) from Non-anchored functions to Consumer (optional). + +Sequence diagram showing the workflow of AI/ML model storage and retrieval between Non-RT RIC and Non-anchored functions in SMO/Non-RT RIC FWK. + +Figure 10.4.3-1: Example workflow of AI/ML model storage and retrieval + +# Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.07.17 | 06.00 | Address the received editorial comments | +| 2024.07.09 | 05.00.07 | Implemented CRs:
    INT-2024.06.20-WG2-CR-0083-NonRT RIC Clarification in architecture description-v02.docx
    INT-2024.07.02-WG2-CR-0085-NonRT RIC hanging paragraphs and other fixes-v01.docx | +| 2024.06.25 | 05.00.06 | Implemented CRs:
    ERI.AO-2024.10.06-WG2-CR-0327-Non-RT RIC-AIML workflow services function inference-v02.docx
    ERI.AO-2024.05.31-WG2-CR-0318-Non-RT RIC-R1InterfaceUpdate-v03.docx
    INT-2024.06.14-WG2-CR-0082-NonRT RIC Remove EN of performance monitoring-v01.docx | +| 2024.06.14 | 05.00.05 | Implemented CRs:
    INT-2024.02.16-WG2-CR-0071-E2E flow for A1 policy creation with a Near-RT RIC id-v04.docx
    ERI-2024.06.06-WG2-CR-0324-Non-RT RIC-R1 Service manangement and exposure-v01.docx | +| 2024.05.16 | 05.00.04 | Implemented CRs:
    NEC.AO-2023.11.22-WG2-CR-0046-Non RT RIC ARCH-AIML model deployment requirement-v3.docx
    ERI-2024.03.20-WG2-CR-0291-Non-RT RIC -Updates to R1 Termination-v04.docx | +| 2024.04.03 | 05.00.03 | Implemented CR:
    INT.AO-2024.03.11-WG2-CR-0073-Non-RT RIC TS AIML performance monitoring update-v03.docx | +| 2024.03.11 | 05.00.02 | Implemented CRs:
    NOK-2024.02.14-WG2-CR-0129-NonRT RIC ARC_producer consumer spelling_v01.docx
    INT-2024.02.15-WG2-CR-0068-Update Non-RT RIC clause 9-v01.docx
    INT-2024.02.16-WG2-CR-0069-Update references in Non-RT RIC-v01.docx
    INT-2024.02.15-WG2-CR-0065-Update Non-RT RIC clause 4-v02.docx
    CMCC.AO-2023.05.30-WG2-CR-0017-AIML model training capability discover services-v3.docx
    NOK-2024.02.20-WG2-CR-0138-NonRT RIC ARCH_NearRT RIC selection optional_v01.docx
    NOK-2024.02.15-WG2-CR-0135-NonRT RIC ARCH_AuthN AuthZ functionality placement_v03.docx | +| 2024.02.07 | 05.00.01 | Implemented CRs:
    INT-2023.12.28-WG2-CR-0064-Update notes on anchored and non-anchored functions-v01.docx
    NEC.AO-2023.11.22-WG2-CR-0049-Non RT RIC ARCH-AIML model registration requirement-v3.docx
    NEC.AO-2023.11.22-WG2-CR-0048-Non RT RIC ARCH-AIML model discovery requirement-v3.docx
    ERI-2024.01.25-WG2-CR-0258-Non-RT-RIC-Arch-update on the DME Requirement-v02.docx | +| 2023.11.16 | 05.00 | Address the received editorial comments | +| 2023.11.10 | 04.00.04 | Implemented CRs:
    NOK-2023.10.30-WG2-CR-0115-NonRT RIC ARCH-DME type terminology cleanup_v01.docx
    INT-2023.11.01-WG2-CR-0062-Editable reference architecture figure-v01.docx | +| 2023.11.07 | 04.00.03 | Implemented CRs:
    NOK-2023.10.17-WG2-CR-0110-NonRT RIC ARCH-Update rApp instance definition_v01.docx
    INT.AO-2023.10.10-WG2-CR-0056-Non-RT RIC ARCH TS ODR update-v03.docx
    INT-2023.10.19-WG2-CR-0058-rApp registration from SME to rApp management-v01.docx
    INT.AO-2023.10.20-WG2-CR-0060-Non-RT RIC ARCH TS ODR update part 2-v01.zip
    INT.AO-2023.10.19-WG2-CR-0059-ML model terms-v01.docx | + +| | | | +|------------|----------|---------------------------------------------------------------------------------------------------------| +| 2023.10.17 | 04.00.02 | Implemented CR:
    INT.AO-2023.09.27-WG2-CR-0054-rAppld definition in Non-RT RIC Arch-v03.docx | +| 2023.08.31 | 04.00.01 | Implemented CR:
    NEC.AO-2023.08.02-WG2-CR-0040-Non RT RIC ARCH-AIML model deployment services-v4.docx | +| 2023.07.28 | 04.00 | Address the received editorial comments | \ No newline at end of file diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/036a68dd6e3ee67f303295d1162c6838_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/036a68dd6e3ee67f303295d1162c6838_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9501289dd3c7dcb3edee8e9f4c17c34ad6778ed2 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/036a68dd6e3ee67f303295d1162c6838_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e5babfeb65d4ebefef8410c2e30e82ed980cd103f9d5222a07af0b0726d2a514 +size 4279 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/04773b3f348a1a45288dcd3231005d8c_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/04773b3f348a1a45288dcd3231005d8c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e8c74235aab2c7c0e4e223e3bdcb615be334aff3 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/04773b3f348a1a45288dcd3231005d8c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:80b13fcc376083e3338742ed0fe1a0f76952fbe37892d1255288a567e014c859 +size 4265 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/19593fb5f334da14805463eb61078b42_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/19593fb5f334da14805463eb61078b42_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6cdbd9ca6e8967132627f04f53d1cce42fc9f4c6 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/19593fb5f334da14805463eb61078b42_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2f4ec076e33d2552c32408f17e32fc85e688e29351b2ef822215ba8bdd193c2e +size 75583 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/218e3984130872989f67f8d17c9e8eb0_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/218e3984130872989f67f8d17c9e8eb0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1437b9806f4b0becf38489daa1e3e94c946e38e2 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/218e3984130872989f67f8d17c9e8eb0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:31c34c11bbc1c4a5831876d608621319e83202240897f41029e6f7bd1e6c492d +size 4287 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/221fbd53ec7185e02f7415d103cb9899_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/221fbd53ec7185e02f7415d103cb9899_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..85697bd5633457f95ec7041457fa41d56664f726 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/221fbd53ec7185e02f7415d103cb9899_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:24cd4c08e563019a692ebc6cb1f048eeed9d5b51e4ae790028fc1670b174ed3b +size 13949 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/24029fc3d3c4b1fd3e90e09ca2749a03_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/24029fc3d3c4b1fd3e90e09ca2749a03_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..225b010fed574ebf97bff2c301508de39dd10d34 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/24029fc3d3c4b1fd3e90e09ca2749a03_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3c41cb8c97d1df98e00fecaf55b3bc52ef99380c93795aefda63ebe8b03218e1 +size 54817 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/28eae84d96d7831d9108238f3c0d8873_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/28eae84d96d7831d9108238f3c0d8873_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7de08eb2768464bbddb23887e1818804dee051d0 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/28eae84d96d7831d9108238f3c0d8873_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7dd31925f59bec0177b4d653492a7ff783c92eddcbf3420730e2ccf50f60fb12 +size 70772 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/3a36e3389e7782c36abc48820b746158_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/3a36e3389e7782c36abc48820b746158_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3860a3997bd010316fbcd53fe3a4208a214000a1 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/3a36e3389e7782c36abc48820b746158_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3c0fb4b1dc97e8b1f182fd7005bc91336e399076c2c856f92a8ddf509b717bac +size 4392 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/3eca52b55e75e56f3cbe39a63c7f66e7_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/3eca52b55e75e56f3cbe39a63c7f66e7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ce2210465b78c1144fb7fe2b67dc30f00948860c --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/3eca52b55e75e56f3cbe39a63c7f66e7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bd4657cf5fa4dd2f64609cc42d075c990e703022795efa18807bea81cd0044d1 +size 43899 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/45e184e347ffea283483eb74782ca985_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/45e184e347ffea283483eb74782ca985_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f90cedbce22821ecf9eae1f12c5990caab05af7 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/45e184e347ffea283483eb74782ca985_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9f5c54f25c300ce8025ac2adc2e450eeacdb3b4946f40ef63aeb7a5b6f246b9b +size 14492 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/47276ce5937744509087208ef7ec3a87_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/47276ce5937744509087208ef7ec3a87_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de6d7c1d7d931cf5ff779757dcf75e14053ed557 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/47276ce5937744509087208ef7ec3a87_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6cac7f73b41d2764f3f4ed059da222e4ffbf6dd558f84ee14422ca3dcc525567 +size 165804 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/48de0a55b599601da841404d9769a38b_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/48de0a55b599601da841404d9769a38b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..441ed293f4c28ffe0d9adaa031a7357fec483595 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/48de0a55b599601da841404d9769a38b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b250f59f4bd6304b4754887e12284b5da316816183d48b31328765419322d276 +size 13702 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/4d99ea38aa306bbdb00e5ccefc493772_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/4d99ea38aa306bbdb00e5ccefc493772_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1fc78b86cde9e7a5bf8c61ad7800178d060ad89d --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/4d99ea38aa306bbdb00e5ccefc493772_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:618d5091740a1631622c0debba470f582af94da7293bb09beb0c349d077fb7a5 +size 77696 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/54f607a04d2807a2235a11e93fa1b538_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/54f607a04d2807a2235a11e93fa1b538_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..20f584b1cd8988b81906f05989f0d5acf83e0126 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/54f607a04d2807a2235a11e93fa1b538_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:86de085b9675f0da78ce7e787e5c7c072313a389d74992f62f0f4f09ac161e37 +size 222525 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/595cca78817deab0483536d3e0fe5e67_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/595cca78817deab0483536d3e0fe5e67_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f2a38a59b0aa4f2a935e6c7bf740d32c50c52257 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/595cca78817deab0483536d3e0fe5e67_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:429dd32ac668406c6ce0dc027ac398d495bb5986ffeec0e4386171c2344a3a26 +size 4261 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/7f70314ff6eec67c0907a33ce1354015_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/7f70314ff6eec67c0907a33ce1354015_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7cc2d668d1224124135a300202b16d87e0e97cb2 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/7f70314ff6eec67c0907a33ce1354015_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e053ea3399fa9d4fcfbf91a4532d1c48cfb3898a61b59922a7dd166d535a96ae +size 236024 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/88be7a9bfb2cc9b3c882eecb3a834da9_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/88be7a9bfb2cc9b3c882eecb3a834da9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..569d99eaca0054c70e5b44cf65697a111a14411f --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/88be7a9bfb2cc9b3c882eecb3a834da9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dab8cc4cc38e2b038cff2380403c8eac3aff620dbad224bdde3b54427b5ae2d1 +size 4307 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/9f3b40922919ae6cb6a4777911cedbc0_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/9f3b40922919ae6cb6a4777911cedbc0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..31f0d330d18f019d95e339c1f41dc66056052433 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/9f3b40922919ae6cb6a4777911cedbc0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dbdea29561c2e2df86ae1900f37c34814e39c46fee9cecde438cbe5379acd212 +size 115972 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/b63c17ba7b9636567aa30f33c467ae5d_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/b63c17ba7b9636567aa30f33c467ae5d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..49230bfa69fedc3fca5e28cd7451f96ea4a98ccd --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/b63c17ba7b9636567aa30f33c467ae5d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bf47a76b5c5393799ccc487e50b72f8f2d64317175a5852903e249e2b1bd5e8c +size 4226 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/c783058354dd4ee8b0958ed0947b8dca_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/c783058354dd4ee8b0958ed0947b8dca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e6891441bf71b85ce57c5c5c34d597fe2f98259 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/c783058354dd4ee8b0958ed0947b8dca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a23cef1808833e0731a6bba7957fbee4dbd42f031a98c627f8fdb87b27349dfe +size 123508 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/d3915a6ca894cf45cc9cf39d597aa1cc_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/d3915a6ca894cf45cc9cf39d597aa1cc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fbc5d1b8a62381bc9311b0cb74217b52a2309dc8 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/d3915a6ca894cf45cc9cf39d597aa1cc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9d054fa19e4c11b2562bac2e295efa254ce09ca94b7c1d12e9db300d27340ed1 +size 4280 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/f5ae098d474fc86f04350919ee56d5f2_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/f5ae098d474fc86f04350919ee56d5f2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ea264bbe576d26618326ccca684d1d8909841af4 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/f5ae098d474fc86f04350919ee56d5f2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7048ed8e5cc81bc4e6fbb7c333ac13231a175f0ab59d9d32b90b1929e1c5c2dc +size 230539 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/f62634f37aaf6a26f1e46cf2b2f6d0ef_img.jpg b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/f62634f37aaf6a26f1e46cf2b2f6d0ef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e6de86082e7327ae2294c2db32bba88511e0d37d --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/f62634f37aaf6a26f1e46cf2b2f6d0ef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:49db17d04e551b67b3f523c9b2eaf030d8ac3bcde21f643ebef73c53c4898f76 +size 4144 diff --git a/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/raw.md b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..ddc13f144cc66b2740326a472f7b053b54dcf938 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01/raw.md @@ -0,0 +1,1706 @@ + + +# O-RAN Working Group 2 Non-RT RIC: Functional Architecture + +--- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Working Group 2****Non-RT RIC: Functional Architecture** --- + +Copyright © 2021 by O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in the Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +# --- 1 Revision History + +| Date | Revision | Author | Description | +|------------|----------|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2020.04.10 | 01.00.00 | CMCC, Intel | Document skeleton | +| 2020.05.07 | 01.00.01 | Intel, CMCC | Addressed comments from email discussion
    Captured agreements made in WG2 weekly meeting on May 07 th , 2020 | +| 2020.06.17 | 01.00.02 | Intel, CMCC | Following three CRs are endorsed
    ATT.AO-2020.05.05-WG2-CR-002-RAPPS-INTF-Non-RT-RIC-v03.docx
    INT.AO-2020.06.11-WG2-CR-0001-Non-RT RIC Functional Architecture Diagram-v05.docx
    INT.AO-2020.06.03-WG2-CR-0002-Skeleton update-v01.docx | +| 2020.10.29 | 01.00.03 | Intel, CMCC | Following seven CRs are endorsed
    SAM.AO-2020.07.23-WG2-CR-0002-Non-RT-RIC-ARCH-TR-v02.docx
    INT.AO-2020.10.01-WG2-CR-0005-A1 termination and funtions-v03.docx
    ATT.AO-2020.07.22-WG2-CR-003-R1-Intf-Reqts-v15.docx
    SAM.AO-2020.10.21-WG2-CR-0003-Non-RT-RIC-ARCH-TR-v02.docx
    INT.AO-2020.10.21-WG2-CR-0008-ML training host and model repository-v03.docx
    INT.AO-2020.10.29-WG2-CR-0009-Clean up-v01.docx
    NOK-2020.10.28-WG2-CR-0001-Non-RT-RIC Functional Architecture Scope-v02.docx | +| 2020.10.30 | 01.00.04 | Intel, CMCC | Removed Annex A: Deployment Scenarios
    Corrected some cross references | +| 2020.11.02 | 01.00.05 | CMCC, Intel | Following CR is endorsed
    CMCC.AO-2020.10.15-WG2-CR-0003-Non-RT-RIC-ARCH-TR-v03.docx
    Editorial updates with removing the editor notes. | +| 2020.11.16 | 01.00 | CMCC, Intel | Addressed editorial updates in the following document
    WG2-Non-RT RIC ARCH TR-v01.00.05-review comments-INT_ERI_NOK_JIO.xlsx | +| 2020.12.13 | 01.01.01 | Intel, CMCC | Following CR is endorsed
    IBM.AO-2020.07.15-WG2-CR-0004-Non-RT RIC Functional Architecture Diagram-v06.docx | +| 2021.01.28 | 01.01.02 | Intel, CMCC | Following CR is endorsed
    INT.AO-2020.12.16-WG2-CR-0010-Human-Machine Interface for Training-v01.docx | + +| | | | | +|------------|----------|-------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2021.03.05 | 01.01.03 | Intel, CMCC |

    Following twelve CRs are endorsed

    NEC.AO-2021.02.03-O-RAN-CR-0002- Definition of function in Non-RT RIC ARCH-v03.docx

    NOK-2021.02.03-WG2-CR-0004-mapping-SBA-vs-functional-arch-v05.docx

    NOK-2020.12.07-WG2-CR-0001-Non-RT-RIC-Functional-Architecture-SBA-v07.docx

    NOK-2021.01.19-WG2-CR-0003-R1-services-v07.docx

    NOK-2021.02.09-WG2-CR-0006-Integration-services-v03.docx

    NOK-2021.02.03-WG2-CR-0007-non-RT-RIC-FWK-in-SB-view-v02.docx

    NEC.AO-2021.02.09-O-RAN-CR-0003- SBA-based Non-RT RIC ARCH-v01.docx

    NOK-2021.02.09-WG2-CR-0005-harmonizing-functionalities-functions-services-v04.docx

    NOK-2021.03.02-WG2-CR-0010-title-of-Section-5.4.3-v01.docx

    NOK-2021.03.02-WG2-CR-0011-title-of-Section-5.4.2-v01.docx

    NOK-2021.03.01-WG2-CR-0008-harmonizing-AI-ML-functionalities-v03.docx

    NOK-2021.03.02-WG2-CR-0009-Integration-services-in-the-R1-interface-general-principles-v02.docx

    | +| 2021.03.12 | 01.01 | Intel, CMCC |

    Addressed editorial comments in the following document

    WG2-Non-RT-RIC-ARCH-TR-v01.01.03-review comments-JIO-Intel.xlsx

    | + +## Contents + +| | | +|----------------------------------------------------------------|----| +| Revision History..... | 2 | +| 1 Introduction..... | 7 | +| 1.1 Scope..... | 7 | +| 1.2 References..... | 7 | +| 1.3 Definitions and Abbreviations..... | 8 | +| 1.3.1 Definitions..... | 8 | +| 1.3.2 Abbreviations..... | 9 | +| 2 Overview of Non-RT RIC..... | 9 | +| 2.1 Non-RT RIC in O-RAN Overall Architecture..... | 9 | +| 2.2 Non-RT RIC Architecture Functional View Diagram..... | 13 | +| 2.2a Non-RT RIC Architecture Service-based View..... | 14 | +| 2.2a.1 Non-RT RIC Architecture Service-based View Diagram..... | 15 | +| 2.3 rApp Definition..... | 16 | +| 2.4 Non-RT RIC Framework..... | 16 | +| 2.4.1 Non-RT RIC Framework in Functional View..... | 16 | +| 2.4.2 Non-RT RIC Framework in a Service-based View..... | 16 | +| 2.5 External Interfaces..... | 17 | +| 2.5.1 A1 Interface..... | 17 | +| 2.5.2 External EI interface..... | 17 | +| 2.5.3 External AI/ML interface..... | 18 | +| 2.5.4 Human-Machine interface..... | 18 | +| 3 Study on Functionalities, Functions and Services..... | 19 | +| 3.1 Interface termination functions..... | 19 | +| 3.1.1 A1 interface termination..... | 19 | +| 3.1.2 External EI termination..... | 19 | +| 3.1.3 External AI/ML termination..... | 20 | +| 3.1.4 Human-Machine termination..... | 20 | +| 3.2 A1 Functionalities..... | 22 | +| 3.2.1 A1-P functionalities..... | 22 | +| 3.2.2 A1-EI functionalities..... | 22 | +| 3.2.3 A1-ML functionalities..... | 22 | + +| | | | | +|----|-------|-------------------------------------------------------------|----| +| 1 | 3.3 | AI/ML Functionalities ..... | 22 | +| 2 | 3.3.1 | ML Training ..... | 22 | +| 3 | 3.3.2 | ML Model Repository Functionality ..... | 23 | +| 4 | 3.3.3 | AI/ML Monitoring ..... | 24 | +| 5 | 3.4 | R1 Services ..... | 26 | +| 6 | 3.4.1 | General Description ..... | 26 | +| 7 | 3.4.2 | General Principles ..... | 27 | +| 8 | 3.4.3 | Data Management and Exposure Services ..... | 28 | +| 9 | 3.4.4 | Integration Services ..... | 30 | +| 10 | 3.5 | rApp Supporting Functions ..... | 30 | +| 11 | 3.6 | Other “Implementation Variable” Functions ..... | 30 | +| 12 | 4 | Requirements ..... | 30 | +| 13 | 4.1 | R1 Interface Requirements ..... | 30 | +| 14 | 4.1.1 | Non-RT RIC Framework Requirements ..... | 30 | +| 15 | 4.1.2 | rApp Requirements ..... | 32 | +| 16 | | Annex A (Informative): Non-RT RIC Processing Examples ..... | 34 | +| 17 | A.1 | Introduction to Illustrative Example ..... | 34 | +| 18 | A.2 | R1 Processing Examples ..... | 35 | +| 19 | A.2.1 | R1 Data Registration Services Examples ..... | 35 | +| 20 | | Annex ZZZ: O-RAN Adopter License Agreement ..... | 48 | +| 21 | | Section 1: DEFINITIONS ..... | 48 | +| 22 | | Section 2: COPYRIGHT LICENSE ..... | 48 | +| 23 | | Section 3: FRAND LICENSE ..... | 49 | +| 24 | | Section 4: TERM AND TERMINATION ..... | 49 | +| 25 | | Section 5: CONFIDENTIALITY ..... | 50 | +| 26 | | Section 6: INDEMNIFICATION ..... | 50 | +| 27 | | Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 50 | +| 28 | | Section 8: ASSIGNMENT ..... | 50 | +| 29 | | Section 9: THIRD-PARTY BENEFICIARY RIGHTS ..... | 51 | +| 30 | | Section 10: BINDING ON AFFILIATES ..... | 51 | +| 31 | | Section 11: GENERAL ..... | 51 | +| 32 | | | | + +# 1 Introduction + +## 1.1 Scope + +This Technical Report has been produced by the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Release xx.yy.zz + +where: + +xx the first two-digit value is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document shall have xx=01). + +yy the second two-digit value is incremented when editorial only changes have been incorporated in the document. + +zz the third two-digit value is included only in working versions of the document indicating incremental changes during the editing process; externally published documents never have this third two-digit value included. + +The present document provides the technical report for the overall functional architecture of the Non-RT RIC (RAN Intelligent Controller). This document collects concepts and requirements that are intended to be used in the subsequent specification of the Non-RT RIC architecture. It is not intended to define normative requirements for the conformance of implementations. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document *in the same* Release as the present document. + +- [1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [2] O-RAN-WG3.E2GAP, "O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 General Aspects and Principles". +- [3] O-RAN-WG3.E2AP, "O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Application Protocol (E2AP)". +- [4] O-RAN-WG1.OAM Architecture, "O-RAN Operations and Maintenance Architecture". +- [5] O-RAN-WG1.O1-Interface, "O-RAN Operations and Maintenance Interface Specification". +- [6] O-RAN-WG2.A1.UseCaseRequirements, "O-RAN Working Group 2, Use Case and Requirements". + +- 1 [7] O-RAN-WG2.A1.GA&P, “O-RAN Working Group 2, A1 interface: General Aspects and +- 2 Principles”. +- 3 [8] O-RAN-WG2.A1.AP, “O-RAN Working Group 2, A1 Interface: Application Protocol”. +- 4 [9] O-RAN-WG2.A1.TP, “O-RAN Working Group 2, A1 Interface: Transport Protocol”. +- 5 [10] O-RAN-WG1.O-RAN Architecture, “O-RAN Working Group 1, O-RAN Architecture +- 6 Description”. +- 7 [11] O-RAN-WG2.O-RAN Architecture, “O-RAN Working Group 2, AI/ML Workflow description +- 8 and Requirements”. +- 9 [12] ETSI GS ZSM 002, “Zero-touch network and Service Management (ZSM); Reference +- 10 Architecture”. + +# 11 1.3 Definitions and Abbreviations + +### 12 1.3.1 Definitions + +- 13 For the purposes of the present document, the terms and definitions given in TR 21.905 [1] and the following apply. +- 14 A term defined in the present document takes precedence over the definition of the same term, if any, in TR 21.905 [1]. +- 15 **Non-RT RIC**(O-RAN non-real-time RAN Intelligent Controller): a logical function that enables non-real-time control +- 16 and optimization of RAN elements and resources, AI/ML workflow including model training and updates, and policy- +- 17 based guidance of applications/features in Near-RT RIC. +- 18 **Near-RT RIC** (O-RAN near-real-time RAN Intelligent Controller): a logical function that enables near-real-time control +- 19 and optimization of RAN elements and resources via fine-grained (e.g. UE basis, Cell basis) data collection and actions +- 20 over E2 interface. +- 21 **O-CU**: O-RAN Central Unit: a logical node hosting RRC, SDAP and PDCP protocols. +- 22 **O-CU-CP**: O-RAN Central Unit – Control Plane: a logical node hosting the RRC and the control plane part of the PDCP +- 23 protocol. +- 24 **O-CU-UP**: O-RAN Central Unit – User Plane: a logical node hosting the user plane part of the PDCP protocol and the +- 25 SDAP protocol. +- 26 **O-DU**: O-RAN Distributed Unit: a logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional +- 27 split. +- 28 **O-RU**: O-RAN Radio Unit: a logical node hosting Low-PHY layer and RF processing based on a lower layer functional +- 29 split. This is similar to 3GPP’s “TRP” or “RRH” but more specific in including the Low-PHY layer (FFT/iFFT, PRACH +- 30 extraction). +- 31 **O-eNB** (O-RAN eNB): an eNB or ng-eNB that supports E2 interface. +- 32 **O1**: Interface between orchestration & management entities (Orchestration/NMS) and O-RAN managed elements, for +- 33 operation and management, by which FCAPS management, Software management, File management and other similar +- 34 functions shall be achieved. +- 35 **SMO**: Service Management and Orchestration system. +- 36 **A1**: Interface between Non-RT RIC and Near-RT RIC to enable policy-driven guidance of Near-RT RIC +- 37 applications/functions, and support AI/ML workflow. +- 38 **E2**: Interface connecting the Near-RT RIC and one or more O-CU-CPs, one or more O-CU-UPs, and one or more O-DUs. + +**E2 Node:** a logical node terminating E2 interface. In this version of the specification, ORAN nodes terminating E2 interface are: + +- for NR access: O-CU-CP, O-CU-UP, O-DU or any combination as defined in [4]; +- for E-UTRA access: O-eNB. + +**rApp:** An application designed to run on the Non-RT RIC. Such modular application leverages the functionality exposed by the Non-RT RIC to provide added value services relative to intelligent RAN optimization and operation + +**xApp:** An application designed to run on the Near-RT RIC. Such an application is likely to consist of one or more microservices and at the point of on-boarding will identify which data it consumes and which data it provides. The application is independent of the Near-RT RIC and may be provided by any third party. The E2 enables a direct association between the xApp and the RAN functionality. + +**O-Cloud:** O-Cloud is a cloud computing platform comprising a collection of physical infrastructure nodes that meet O-RAN requirements to host the relevant O-RAN functions (such as Near-RT RIC, O-CU-CP, O-CU-UP, and O-DU), the supporting software components (such as Operating System, Virtual Machine Monitor, Container Runtime, etc.) and the appropriate management and orchestration functions. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the following abbreviations apply. + +| | | +|-------------|-------------------------------------------| +| EI | Enrichment Information | +| LCM | Lifecycle Management | +| ML | Machine Learning | +| Non-RT RIC | Non-real-time RAN Intelligent Controller | +| Near-RT RIC | Near-real-time RAN Intelligent Controller | +| RAN | Radio Access Network | +| SLA | Service Level Agreement | +| SMO | Service Management and Orchestration | +| TLS | Transport Layer Security | +| ZSM | Zero-touch network and Service Management | + +# 2 Overview of Non-RT RIC + +## 2.1 Non-RT RIC in O-RAN Overall Architecture + +In the O-RAN Logical Architecture, as seen in Figure 2.1-1 below, the Non-RT RIC is portrayed as a function that resides within the Service Management and Orchestration Framework and which has a direct association with the A1 interface. The Non-RT RIC's position internal to, as opposed to interfacing with, the SMO is intended to communicate that the Non-RT RIC is comprised of a subset of functionality of the SMO itself. + +The direct association with the A1 interface is intended to convey that the functionality of the Non-RT RIC is directly responsible for driving that which is sent and received across the A1 interface. The O1 and O2 interfaces are shown as being directly associated with the SMO Framework itself, that which is not specific to the Non-RT RIC. This representation is intended to communicate that the SMO Framework functionality, but not the Non-RT RIC functionality therein, is directly responsible for driving that which is carried across these interfaces. + +O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01 + +The representation of the Non-RT RIC in the center (as opposed to the bordering the bottom edge) of the SMO Framework visibly indicates that the Non-RT RIC can access SMO Framework functionality, including influencing that which is carried over the O1 interface. While it is not prohibited from accessing any SMO Framework functionality, the Non-RT RIC's role of RAN resource optimization per current O-RAN definition implies that the Non-RT RIC would only access SMO Framework functionality for that purpose. Thus, the Non-RT RIC would influence that which is carried across the O2 interface only to the extent that the O-Cloud is considered a RAN resource. + +Image: O-RAN ALLIANCE Logo + +![Figure 2.1-1: Logical Architecture of O-RAN](9f3b40922919ae6cb6a4777911cedbc0_img.jpg) + +A block diagram showing the Service Management and Orchestration Framework containing the Non-Real Time RIC. It connects via O1, O2, and A1 interfaces to various components including Near-Real Time RAN Intelligent Controller (RIC), O-eNB, O-CU-CP, O-CU-UP, O-DU, O-RU, and O-Cloud. Various interfaces like E2, E1, F1-c, F1-u, X2-c, X2-u, NG-u, Xn-u, Xn-c, NG-c are shown connecting these components. + +Figure 2.1-1: Logical Architecture of O-RAN + +**Figure 2.1-1: Logical Architecture of O-RAN** + +Similar to the Near-RT RIC, there is business value in visualizing the Non-RT RIC as being modularly extensible, that functional extensibility being accomplished through modular applications that can be understood as running within the Non-RT RIC function itself. Such applications have different lifecycles from the "framework" in which they run. For convenience we will use the term "rApp" to refer to such applications. + +Because rApps are associated with the Non-RT RIC, any framework services exposed to the rApps can be considered as being exposed by the Non-RT RIC. Some of these framework services, for example access to O1, are not specific to the Non-RT RIC, whereas others, such as access to A1, are specific to the Non-RT RIC. + +There is a clear business benefit to allow "porting" of a Non-RT RIC application from one SMO Framework implementation to another. Hence it would be useful for the O-RAN Alliance to define an open and standard interface through which the Non-RT RIC exposes SMO Framework functionalities to "rApps" via the R1 Services exposure functionality. We will refer to this as the "R1" interface. + +With the above understandings, the Non-RT RIC itself can now be described as follows: + +- Non-RT RIC - That functionality that drives the content carried across the A1 interface to the RAN. It can also access other SMO Framework functionality, for example influencing that which is carried across the O1-CM interface. It is comprised of two sub-functions: + - Non-RT RIC Framework - That functionality internal to the SMO Framework itself that: + - Logically terminates the A1 interface to the Near-RT RIC. + +Copyright © 2021 by the O-RAN Alliance e.V. +Your use is subject to the terms of the O-RAN Adopter License Agreement in Annex ZZZ. + +10 + +- Exposes to rApps, via its R1 interface, the set of internal SMO Framework services needed for their runtime processing. +- Non-RT RIC Applications (rApps) – Modular applications that leverage the functionality exposed by the Non-RT RIC Framework to provide added value services relative to RAN operation. Examples of such added value services include: + - Driving content (Policy or Enrichment Information) across the A1 interface. + - Recommending content for the O1 interface. + - Generating “enrichment information” for the use of other rApps. + +Figure 2.1-2 graphically illustrates these definitions. + +As observed above, rApps will require services from the R1 interface that are not necessarily associated with the Non-RT RIC Framework, such as access to O1, data sharing services, and access to RAN inventory. The Non-RT RIC Framework, via its R1 Services exposure functionality, would be responsible for exposing all of these services to the rApps, irrespective of the location within the SMO Framework of the provider of those services. + +A declared business need to “port” a Non-RT RIC Framework from one SMO Framework implementation to another would drive the need for a formal interface within the SMO Framework between the Non-RT RIC Framework and the rest of the SMO Framework. Absent this, different implementations of SMO Framework could make different design choices as to how to manifest the boundary between the Non-RT RIC Framework and the rest of the SMO Framework, or even to choose not to implement a clear boundary at all. + +The lack of a clear boundary between the Non-RT RIC and the rest of the SMO Framework need not negatively impact the ability to proceed with a formal definition of the R1 interface nor impact definition of the R1 Services exposure functionality needed to support this interface. Rather, such definitions can proceed, agnostic to the source of the SMO Framework services being exposed. However, it may be useful to define some terms that we can use to help us in discussion of these topics. + +Particularly it would be useful to have terms to distinguish between: + +- An indication that a particular R1-exposed functionality is sourced from the Non-RT RIC Framework. This functionality would be considered “inherent” to the Non-RT RIC Framework. +- An indication that it is left as an SMO Framework implementation decision whether a particular R1-exposed functionality is sourced from the Non-RT RIC Framework or not. +- An indication that a particular R1-exposed functionality is not sourced from the Non-RT RIC Framework. This functionality would be considered “inherent” to the SMO Framework itself, but not the Non-RT RIC Framework. + +The functionality that is inherent to the Non-RT RIC Framework is that functionality related to the two interfaces that the Non-RT RIC “owns”, specifically that functionality needed to drive the A1 and R1 interfaces. The O1 and O2 interfaces are clear examples of functionality of the third bullet. + +The term “Implementation Variable Functionality” is descriptive of that functionality described in the second bullet. Examples might include functionalities such as “Data Sharing”, “Analytic Services”, “Policy”, “RAN Inventory”, “General ML/AI Model LCM/Catalog”, RAN Mediation/Control”, “RAN Configuration Database”, “PM Short Term Data Repository”, “Operations Intent Interface” and “External Interfaces”. + +These terms and the relationships between the functions they describe can be seen in Figure 2.1-2 below. + +![Figure 2.1-2: Exposure of SMO Framework Services to rApps. The diagram illustrates the SMO Framework and its interaction with Non-RT RIC Applications (rApps). The SMO Framework is divided into Non-RT RIC and Inherent Non-RT RIC Framework Functionality. The Non-RT RIC section includes Non-RT RIC Applications (rApps) connected via R1 (Open Standard API) to R1 Services exposure functionality. The Inherent Non-RT RIC Framework Functionality section includes Implementation Variable Functionality and A1 Termination. The SMO Framework is connected to the O-Cloud via O2, O1, and A1 interfaces. The O-Cloud is connected to Other O-RAN xNF and Near-RT RIC. The diagram also shows a Key for Defined O-RAN Interface (Open) and Internal (Outside O-RAN Scope).](24029fc3d3c4b1fd3e90e09ca2749a03_img.jpg) + +Figure 2.1-2: Exposure of SMO Framework Services to rApps. The diagram illustrates the SMO Framework and its interaction with Non-RT RIC Applications (rApps). The SMO Framework is divided into Non-RT RIC and Inherent Non-RT RIC Framework Functionality. The Non-RT RIC section includes Non-RT RIC Applications (rApps) connected via R1 (Open Standard API) to R1 Services exposure functionality. The Inherent Non-RT RIC Framework Functionality section includes Implementation Variable Functionality and A1 Termination. The SMO Framework is connected to the O-Cloud via O2, O1, and A1 interfaces. The O-Cloud is connected to Other O-RAN xNF and Near-RT RIC. The diagram also shows a Key for Defined O-RAN Interface (Open) and Internal (Outside O-RAN Scope). + +**Figure 2.1-2: Exposure of SMO Framework Services to rApps** + +The “Internal” arrows in the diagram represent that it is within the scope of the Non-RT RIC Framework’s R1 Services exposure functionality to expose all required services of the SMO Framework, even those that are not or may not be associated with the Non-RT RIC Framework itself. It is outside of O-RAN’s scope to define the “Internal” mechanism through which these services are exposed to specific SMO Framework implementations. + +Note that each of the endpoint functional blocks of the SMO Framework’s external interfaces have interface termination functions and functionalities associated with them to drive that respective interface. Thus, the Non-RT RIC Framework has associated with it the “A1 Functionalities”, i.e., A1 Policy, A1 EI and A1 ML, required to drive the A1 interface, as well as the A1 interface logical termination functions. Examples of R1 Services exposure functionality would include what is needed to manage the runtime interactions of individual rApps with the Non-RT RIC Framework itself. + +The Non-RT RIC architecture lends itself to be described by using two views, based on different approaches: a functional approach and a service-based approach. In the functional approach, the architectural view focuses on “packaging” functionalities into functions, i.e., logical entities with well-defined behaviour, connected by interfaces. In a service-based approach, the architectural view focuses on describing the functionalities as capabilities offered through services by service producer entities to service consumer entities, inspired by the service-based design principles defined in ETSI ZSM [12]. Service consumer and service producer entities are interconnected by means of communication support that enable adequate communication patterns e.g. 1-1, 1-many, pub-sub, routed etc. In general, a functional architectural view can be regarded as a deployment option, or specific realization, allowed by the service-based architectural view, and both provide the same functionalities. As described in the following, this principle is valid also for the Non-RT RIC case. + +Following the principles above, Section 2.2 provides the functional view of the Non-RT RIC architecture, whereas Section 2.2a shows the service-based view. The functional decomposition of the Non-RT RIC shown in Section 2.2 facilitates analysis and description of the required functionality of the combination of Non-RT RIC and SMO framework. Based on that analysis, the service-based view of the Non-RT RIC architecture focuses on interoperability aspects – namely the interfaces with other O-RAN components and the R1 services that allow interworking between the Non-RT RIC and the rApps as the main multivendor integration point. To facilitate flexibility of deployment, the service-based architectural view defines SMO and Non-RT RIC capabilities, but abstracts from a detailed representation of functional blocks that realize the capabilities and produce or consume the R1 services. This architectural approach allows multiple different instantiations; the detailed functional view presented in Section 2.2 being one of these possible instantiations. All such instantiations will all be interoperable towards rApps as long as they support the R1 services, and towards other O-RAN system components as long as they support the interfaces defined towards these. + +## 2.2 Non-RT RIC Architecture Functional View Diagram + +![Figure 2.2-1: Non-RT RIC architecture functional view diagram. The diagram illustrates the functional architecture of the Non-RT RIC within the SMO Framework. The SMO Framework (orange) contains the Non-RT RIC (blue) and other SMO framework functions (yellow). The Non-RT RIC includes rApps (rApp 1, rApp 2, ..., rApp n) connected via the R1 (Open APIs for rApps) interface. The Non-RT RIC framework (blue) contains functions like Authentication and authorization, Service registration and discovery, rApp management, A1 Policy, A1 EI, A1 ML, and A1 termination. The SMO Framework also includes External EI, External AI/ML, and Human-Machine interfaces, as well as O2 and O1 termination points. The diagram shows connections to O-Cloud, Near-RT RIC, and E2 Nodes. A legend at the bottom defines the colors and line styles for implementation variability, inherent Non-RT RIC framework functionality, inherent SMO framework functionality, O-RAN defined interface, internal interface, and external interface.](c783058354dd4ee8b0958ed0947b8dca_img.jpg) + +Figure 2.2-1: Non-RT RIC architecture functional view diagram. The diagram illustrates the functional architecture of the Non-RT RIC within the SMO Framework. The SMO Framework (orange) contains the Non-RT RIC (blue) and other SMO framework functions (yellow). The Non-RT RIC includes rApps (rApp 1, rApp 2, ..., rApp n) connected via the R1 (Open APIs for rApps) interface. The Non-RT RIC framework (blue) contains functions like Authentication and authorization, Service registration and discovery, rApp management, A1 Policy, A1 EI, A1 ML, and A1 termination. The SMO Framework also includes External EI, External AI/ML, and Human-Machine interfaces, as well as O2 and O1 termination points. The diagram shows connections to O-Cloud, Near-RT RIC, and E2 Nodes. A legend at the bottom defines the colors and line styles for implementation variability, inherent Non-RT RIC framework functionality, inherent SMO framework functionality, O-RAN defined interface, internal interface, and external interface. + +**Figure 2.2-1: Non-RT RIC architecture functional view diagram** + +Figure 2.2-1 illustrates the Non-RT RIC architecture functional view diagram. Non-RT RIC is an internal functionality of SMO framework, and the diagram shows three categories of components of Non-RT RIC: rApps, Non-RT RIC framework, and Open APIs for rApps. + +- rApp is an application designed to run on the Non-RT RIC, and it is defined in Section 2.3. +- Non-RT RIC framework is a collection of Non-RT RIC framework functions, and it is described in Section 2.4. +- R1 interface (Open APIs for rApps) are Non-RT RIC internal interface between rApps and Non-RT RIC framework, and it is a collection of services, such as service registration and discovery services, AI/ML workflow services, and A1-related services. Note that whether the function that provides the services is in Non-RT RIC framework or in SMO framework is transparent to the open APIs. R1 interface general principles and R1 services are discussed in Section 3.4. + +Note that one Non-RT RIC can connect to multiple Near-RT RICs. + +A function is a logical entity that plays the roles of services producer and/or service consumer. + +Inside the Non-RT RIC framework, there is a set of essential Non-RT RIC framework functions, which is illustrated as the blue area in the diagram. Because these functions are used to support A1 interface and rApps, it is nature to deploy these functions inside Non-RT RIC framework. Such functions are denoted as “inherent Non-RT RIC framework functionality”. As the termination point of A1 interface, “A1 functions” should be regarded as inherent Non-RT RIC functions. “A1 functions” includes “A1 logical termination” and functions to support A1 services defined in [7] [8], i.e., “A1 Policy functions”, “A1 EI functions”, and “A1 ML functions”. + +To facilitate modular rApps, “rApp management functions” and “R1 service exposure functions” are required. “rApp management functions” includes rApp conflict mitigation. This example of rApp management is regarded as inherent to Non-RT RIC framework. Note that functions for rApp orchestration are not part of rApp management functions, and rApp orchestration functions can be part of SMO framework. In the diagram, “other Non-RT RIC framework functions” is used as a placeholder for any other functions inside Non-RT RIC, if identified later during the study. “R1 service exposure functions” includes “service registration and discovery function” and “authentication and authorization + +function”, etc. The services provided by Non-RT RIC framework and SMO framework are discovered by rApps via “services registration and discovery function”. An rApp needs to be authenticated and authorized by the authentication and authorization function before being able to access the required services. + +As discussed in the previous section, functions can fall into the “implementation variability” area, shown as the “yellow” area in the diagram. The deployment of these “implementation variable” functions is left to implementation. If an “implementation variable” function is deployed in the Non-RT RIC in a particular implementation, then this function is regarded as a part of Non-RT RIC framework, and its service is discovered by rApps via “service registration and discovery function”. On the other hand, if an “implementation variable” function is deployed in the SMO framework in one implementation, then this function is not a part of Non-RT RIC framework, and its service is also discovered by rApps via “service registration and discovery function”. + +In Figure 2.2-1, three terminations of external interfaces are demonstrated as examples of “implementation variable” functions: external EI termination, external AI/ML termination, and human-machine termination. External EI termination is connected to external EI sources to import enrichment information for Non-RT RIC applications. External AI/ML termination is connected to external AI/ML server for ML model importation. Human-machine termination is used to inject RAN intent manually. All three terminations can reside inside Non-RT RIC or in SMO (but outside of Non-RT RIC). Note that specification of these external interfaces is for further discussion. There are many more “implementation variable” functions, and examples for those “implementation variable” functions include: AI/ML model training, data analytics, data sharing, etc. In the diagram, “Function 1”, ..., “Function n” are used as placeholders for more “implementation variable” functions. + +The functions depicted in the architecture in Figure 2.2-1 provide the functionalities and services defined in Section 3. + +## 2.2a Non-RT RIC Architecture Service-based View + +The service-based architectural approach is today widely adopted by telco industry. Service-based principles allow to describe an architecture not based on fixed functional components and interfaces between them but based on the definition of services as the central point of architecture consideration. Though there’s no formal definition available, a service-based architecture follows principles of which some are listed below: + +- **Modularity:** The functionality is modularized into a set of services at the appropriate granularity level. +- **Extensibility:** The architecture allows simple extensibility by adding new services and making them discoverable. +- **Functional abstraction:** Service-based architecture abstracts from the complexity and details of the underlying functions that produce the services. +- **Discoverability:** Services are searchable for their availability. +- **Composability:** Services can be composed, forming new services. +- **Reusability:** Since services are modularized, they can be re-used and can be invoked at multiple stages of the business process. +- **Loose coupling:** Services are loosely coupled and independent from one-another. + +Designing an architecture in a service-based fashion allows a great degree of deployment *flexibility* and *future-proofedness*, as it leaves the choice of components that produce and/or consume certain services to the deployment, yet facilitating multi-vendor interoperability through the definition of standardized services respectively standardized service interfaces. Services are produced by service producers and consumed by service consumers through service endpoints. Service-based architecture allows *modularization* of the services rather than the components of a deployment. Service consumers need to be *authenticated* and *authorized* to access services at runtime by policies, rather than pre-assigning fixed consumer-producer relationships at the time the standard is developed. Produced services are *registered* in a registry from which service consumers can *discover* the available services, and the technical parameters how to consume them, + +such as the service endpoint, the data format and access protocol. For the service communication, different possibilities exist. Service consumers can access the service endpoints directly in a point-to-point fashion, after discovering them. Alternatively, service-related communication can be facilitated using an overarching communication framework such as a message bus or service mesh. Using a service-based design for the functionalities that are consumed and/or produced by rApps, these apps can run in any deployment that offers these services, without the need to document implementation variability. Also, future evolution of rApps into more generic smart network management apps is enabled, as such evolved apps would simply be able to discover and use more services. + +### 2.2a.1 Non-RT RIC Architecture Service-based View Diagram + +The diagram in Figure 2.2a-1 shows the decomposition of the Non-RT RIC into Non-RT RIC Framework and rApps, interacting with each other through the R1 services, described in Section 3.4. + +A service is a set of capabilities offered by a service producer to service consumers for consumption through defined endpoints. The purpose of a service is to access, use and control a certain functionality (set of capabilities) available in the system. Production and consumption of services, which are specified, are roles of (software) entities in deployments, however, the exact software entities are not called out in the specification. A service may be standardized by O-RAN Alliance, by another organization, or be proprietary, but it can be made available in the system if it implements a common and standard way to register, to be accessed and controlled. + +According to the above, the architecture in Figure 2.2a-1 depicts the R1 services and the related capabilities which are part of the SMO and Non-RT Framework. Such capabilities also include communication support to enable adequate communication patterns for the service requirements, e.g., 1-1, 1-many, pub-sub, routed etc., inspired by the service-based design principles defined in [12]. Furthermore, the diagram shows that the service-based approach describes consistently how services provide access to Non-RT RIC inherent functionalities, SMO inherent functionalities, implementation variable functionalities and also capabilities external to the SMO. + +The Non-RT RIC service-based architectural view caters for different deployment options, including the one illustrated in Figure 2.2-1, by applying an appropriate configuration of the authorized producers-consumer pairs. + +![Figure 2.2a-1: Non-RT RIC architecture service-based view diagram. The diagram shows the SMO (Service Management Orchestrator) and Non-RT RIC (Non-Real Time Radio Intelligent Controller) components. The SMO includes 'Other SMO capabilities' and 'External capabilities'. The Non-RT RIC includes 'rApp' and 'Non-RT RIC Framework'. The Non-RT RIC Framework is divided into 'Data mgmt. and exposure' (containing 'AI-ML Workflow' and 'External capabilities termination') and 'Service discovery', 'Communication support', and 'Authorization authentication'. The Non-RT RIC Framework also includes 'AI-ML Monitoring', 'Other Non-RT RIC Framework capabilities', and 'A1 termination'. The diagram shows interfaces between the SMO and Non-RT RIC, and between the Non-RT RIC and other entities like 'oCloud', 'Near-RT RIC', and 'E2 nodes'. A legend at the bottom explains the symbols: 'Produced service' (solid line with circle), 'Consumed service' (solid line with circle), 'Standardized interface between O-RAN entities' (double line with diamond), and 'Out of scope interface' (dashed line with diamond).](19593fb5f334da14805463eb61078b42_img.jpg) + +Figure 2.2a-1: Non-RT RIC architecture service-based view diagram. The diagram shows the SMO (Service Management Orchestrator) and Non-RT RIC (Non-Real Time Radio Intelligent Controller) components. The SMO includes 'Other SMO capabilities' and 'External capabilities'. The Non-RT RIC includes 'rApp' and 'Non-RT RIC Framework'. The Non-RT RIC Framework is divided into 'Data mgmt. and exposure' (containing 'AI-ML Workflow' and 'External capabilities termination') and 'Service discovery', 'Communication support', and 'Authorization authentication'. The Non-RT RIC Framework also includes 'AI-ML Monitoring', 'Other Non-RT RIC Framework capabilities', and 'A1 termination'. The diagram shows interfaces between the SMO and Non-RT RIC, and between the Non-RT RIC and other entities like 'oCloud', 'Near-RT RIC', and 'E2 nodes'. A legend at the bottom explains the symbols: 'Produced service' (solid line with circle), 'Consumed service' (solid line with circle), 'Standardized interface between O-RAN entities' (double line with diamond), and 'Out of scope interface' (dashed line with diamond). + +Figure 2.2a-1: Non-RT RIC architecture service-based view + +## 2.3 rApp Definition + +rApps are modular applications that leverage the functionality exposed by the Non-RT RIC to provide added value services relative to intelligent RAN optimization and operation. Examples of such added value services include: + +- Providing policy-based guidance and enrichment information across A1 interface. +- Performing data analytics, AI/ML training, and inference for RAN optimization or for the use of other rApps. +- Recommending configuration management actions over O1 interface. + +## 2.4 Non-RT RIC Framework + +### 2.4.1 Non-RT RIC Framework in Functional View + +In the functional view of the Non-RT RIC architecture in Section 2.2, the Non-RT RIC framework is a collection of Non-RT RIC framework functions. It includes the set of inherent Non-RT RIC framework functions to support A1 interface and rApps, other Non-RT RIC framework functions if any, and “implementation variable” functions which are deployed in Non-RT RIC. Non-RT RIC framework functions provide services to rApps via the open APIs (also referred to as R1 services, described in Section 3.4). In summary, Non-RT RIC framework functions include + +- “rApp supporting functions”, e.g, rApp service exposure functions, rApp conflict mitigation, etc. + - To support interoperability between Non-RT RIC and SMO, Non-RT RIC and SMO can expose their rApp-supporting functions to each other through SMO service exposure function, which is part of rApp service exposure functions. Non-RT RIC can leverage SMO services, for example, data collection and provisioning services, via SMO service exposure function. +- “A1 functions”, e.g., A1 logical termination, A1-Policy coordination and catalog, A1-EI coordination and catalog, etc. +- “AI/ML Monitoring functions”, + - Providing online monitoring functions to AI/ML models in Non-RT RIC. For example, it can adopt a contract-based strategy for run-time monitoring of AI/ML models to support different types of AI/ML algorithm in multi-vendors scenarios. +- “AI/ML workflow functions”, e.g., “AI/ML Model Management Functions”, “AI/ML Data Preparation Functions”, “AI/ML Modeling/Training Functions”, “ML Model Repository”. AI/ML workflow functions are implementation variability functions and can be flexibly deployed within Non-RT RIC, outside Non-RT RIC but within SMO, or even outside SMO. +- Other logical terminations, e.g., external EI termination, external AI/ML termination, human-machine termination, etc. +- Other “implementation variable” functions, e.g., data sharing. + +### 2.4.2 Non-RT RIC Framework in a Service-based View + +In the service-based view of the Non-RT RIC architecture of Section 2.2a, the Non-RT RIC framework is a collection of capabilities to support well defined functionalities. It includes the set of inherent Non-RT RIC framework functionalities for the A1 interface, the support for integration services, other Non-RT RIC framework functionalities if any, and “implementation variable” functionalities which are deployed in Non-RT RIC. Non-RT RIC framework functionalities provide services to rApps via the open APIs (also referred to as R1 services, described in Clause 3.4). In summary, Non-RT RIC framework functionalities include: + +- *Integration services*, providing interoperability between rApps and Non-RT RIC/SMO. The Non-RT RIC Framework, the SMO, and potentially the rApps too can expose their services through a set of capabilities in the Non-RT RIC Framework that enable rApps to register and discover service endpoints, and also to obtain notifications whenever a change in the service availability occurs. In addition, integration services include capabilities to authenticate and authorize the service producers and the service consumers. +- *Data management and exposure* enable the collection and production of data, as well as fetching data from a database. These functionalities cater for having different sources of heterogeneous data which can be delivered directly to a data consumer or through a distribution system. More details are elaborated in Section 3.4.3. Data management and exposure are implementation variability functionalities and can be flexibly deployed within Non-RT RIC, outside Non-RT RIC but within SMO. +- *A1 interface support*, e.g., A1 logical termination, A1-Policy coordination and catalogue, A1-EI coordination and catalogue, etc. +- *AI/ML monitoring*, providing online monitoring to AI/ML models in Non-RT RIC. For example, it can adopt a contract-based strategy for run-time monitoring of AI/ML models to support different types of AI/ML algorithm in multi-vendors scenarios. +- *AI/ML workflow support*, e.g., AI/ML model management and storage, AI/ML data preparation, AI/ML modelling/training. AI/ML workflow functionalities are implementation variability functionalities and can be flexibly deployed within Non-RT RIC, outside Non-RT RIC but within SMO, or even outside SMO. +- Other logical terminations, e.g., external EI termination, external AI/ML termination, human-machine termination, etc. +- Other “implementation variable” functionalities, e.g., data sharing. + +## 2.5 External Interfaces + +### 2.5.1 A1 Interface + +O-RAN-WG2.A1.GA&P [7] specifies A1 interface general aspects and principles. + +O-RAN-WG2.A1.AP [8] specifies A1 interface application protocols. + +O-RAN-WG2.A1.TP [9] specifies A1 interface transport protocols. + +### 2.5.2 External EI interface + +#### 2.5.2.1 External EI interface general principles + +The general principles for the functionalities of an external EI interface are as follows: + +- Support registration of an external source of EI. +- Support transfer of EI from an external source to Non-RT RIC that requests it. +- Support transfer of handshaking messages (e.g. EI request and response messages) between the Non-RT RIC and an external source of EI. + +#### 2.5.2.2 External EI interface objectives + +The external EI interface functionalities facilitate the following: + +- Secure delivery of EI from an external source of EI to the Non-RT RIC. + +- Recognition of EI type by the Non-RT RIC. +- Transfer of EI request messages from the Non-RT RIC to an external source of EI. +- Transfer of EI response messages from an external source of EI to the Non-RT RIC. + +### 2.5.3 External AI/ML interface + +#### 2.5.3.1 External AI/ML interface general principles + +The general principles for the functionalities of an external AI/ML interface are as follows: + +- Support transfer of a trained ML model (and its metadata) from an external AI/ML server to SMO/Non-RT RIC that requests it. +- Support transfer of handshaking messages (e.g. training request and response messages) between the SMO/Non-RT RIC and an external AI/ML server. + +Note: Transfer of training data to an external AI/ML server is FFS. + +#### 2.5.3.2 External AI/ML interface objectives + +The external AI/ML interface functionalities facilitate the following: + +- Secure delivery of trained ML models (and their metadata) from an external AI/ML server to the SMO/Non-RT RIC. +- Transfer of training request messages from the SMO/Non-RT RIC to an external AI/ML server. +- Transfer of training response messages from an external AI/ML server to the SMO/Non-RT RIC. + +### 2.5.4 Human-Machine interface + +The interface is provided by Non-RT RIC for technicians to manually deploy RAN intent and operate rApp . + +As many systems provide Human-Machine interface (e.g., web based UI), Non-RT RIC also provides such functions to technicians for their manual operations. Examples of operations include RAN intent injection, rApp maintenance, and human interaction/intervention for AI/ML training in the SMO/Non-RT RIC. + +This document doesn't limit the implementation of the interface. The interface function could also be integrated into other interfaces to form a unified interface. + +Note: RAN intent may be also imported to SMO/Non-RT RIC by other ways, e.g., from the business support system. + +Note: The details of RAN intent are FFS. + +#### 2.5.4.1 Human-Machine Interface general principles + +The general principles for the functionalities of the Human-Machine interface are as follows: + +- Support for RAN intent injection. +- Support for checking an rApp information. +- Support for suspending a running rApp. +- Support for resuming a pending rApp. + +- Support for human interaction/intervention for AI/ML training. + +Note: The rApp information may include it's running status, etc. + +#### 2.5.4.2 Human-Machine interface objectives + +The Human-Machine interface functionalities facilitate the following: + +- Transfer the RAN intent. +- Provide the information of deployed rApps on the Non-RT RIC. +- Transfer the command of suspending a specified running rApp. +- Transfer the command of resuming a specified pending rApp. +- Transfer the AI/ML training configurations. +- Transfer the AI/ML training status requests and reports. +- Transfer the commands of initiating/suspending/resuming/terminating a training process. + +# --- 3 Study on Functionalities, Functions and Services + +## 3.1 Interface termination functions + +### 3.1.1 A1 interface termination + +The A1 interface termination enables the Non-RT RIC framework to send and receive messages to and from the Near-RT RIC via the A1 interface. The A1 interface termination secures the A1 interface via TLS in A1 protocol stack [9]. A1 messages sent to, and received from, the Near-RT RIC currently include + +- A1 policy creation/update request based on the policy received from the A1-P functions (see Section 3.2.1). +- A1 policy feedback, which is routed to the A1-P functions. +- A1 enrichment information from the A1-EI functions (see Section 3.2.2). +- A1 enrichment information subscription request, which is routed to the A1-EI functions. + +Possible future A1 messages may include + +- A1 machine learning service requests/responses and subscriptions/notifications, to and from the A1-ML functions (see Section 3.2.3). + +Refer to [7, 8, 9] for details on A1 interface specifications. + +### 3.1.2 External EI termination + +The external EI interface termination enables the SMO/Non-RT RIC to receive and send messages via the external EI interface. These include, e.g., handshaking messages sent between the SMO/Non-RT RIC and an external source of EI. The delivery of EI over the external EI interface can be leveraged by rApps to enhance RAN operations. An xApp can also leverage EI that is initially delivered over the external EI interface and then to the Near-RT RIC over the A1 interface. + +The external EI interface termination secures the external EI interface. + +The external EI interface termination routes all incoming messages from an external source of EI to the SMO/Non-RT RIC. The external EI interface termination may decode incoming messages (e.g. ASN.1-encoded messages) from an external source of EI. + +The external EI interface termination performs conversion of external data models (e.g. 5GAA standard-compliant messages) from an external source of EI to facilitate internal messaging for the SMO/Non-RT RIC. + +Figure 3.1-1 shows the connection between the external EI interface termination and an external source of EI via the external EI interface. + +![Diagram showing the connection between an External EI Source and External EI Termination via the External EI Interface.](48de0a55b599601da841404d9769a38b_img.jpg) + +``` + +graph LR + A[External EI Source] <-->|External EI Interface| B[External EI Termination] + +``` + +Diagram showing the connection between an External EI Source and External EI Termination via the External EI Interface. + +**Figure 3.1-1: External EI termination** + +### 3.1.3 External AI/ML termination + +The external AI/ML interface termination enables the SMO/Non-RT RIC to receive and send messages via the external AI/ML interface. These include, e.g., handshaking messages sent between the SMO/Non-RT RIC and an external AI/ML server. + +The external AI/ML interface termination secures the external AI/ML interface. + +The external AI/ML interface termination routes all incoming messages from an external AI/ML server to their intended destinations. For example, it can route a trained ML model to an ML model repository. + +The external AI/ML interface termination may decode incoming messages (e.g. JSON-encoded messages) from an external AI/ML server. + +The external AI/ML interface termination performs conversion of trained ML models (e.g. ONNX standard-compliant model formats) from an external AI/ML server to a model format that is supported by the SMO/Non-RT RIC. + +Figure 3.1-2 shows the connection between the external AI/ML interface termination and an external AI/ML server via the external AI/ML interface. + +![Diagram showing the connection between an External AI/ML Server and External AI/ML Termination via the External AI/ML Interface.](221fbd53ec7185e02f7415d103cb9899_img.jpg) + +``` + +graph LR + A[External AI/ML Server] <-->|External AI/ML Interface| B[External AI/ML Termination] + +``` + +Diagram showing the connection between an External AI/ML Server and External AI/ML Termination via the External AI/ML Interface. + +**Figure 3.1-2: External AI/ML termination** + +### 3.1.4 Human-Machine termination + +The Human-Machine interface enhances the closed-loop mechanism of intelligent end user service experience guarantee and network performance improvement. The interface function includes RAN intent injection, rApp maintenance, and AI/ML training interaction/intervention. + +The Human-Machine interface termination secures the Human-Machine interface. + +The Human-Machine termination receives information of deployed rApps from rApp management function and forwards to the technician via Human-Machine interface. The Human-Machine interface termination routes commands of + +suspending/resuming an rApp from a technician (e.g., with web based UI) to rApp management function. The Human-Machine interface termination may decode incoming messages (e.g. JSON/XML/YANG-encoded messages) from a technician using the portal, e.g. web based UI. + +The Human-Machine termination routes AI/ML training configurations and reporting configurations/requests from technicians to rApps and/or the training host in the SMO/Non-RT RIC. It forwards commands (e.g., initiating, suspending, resuming, terminating, etc.) from a technician to allow human intervention of a specific training process. The Human-Machine termination receives AI/ML training status reports from rApps and/or the training host, and it forwards the status report to technicians. + +A technician can configure a specific training process. The configuration message can contain: + +- The ID for the AI/ML training process. +- The ID for the selected base model. +- The associated App ID (xApp or rApp). +- Training location (e.g., the internal/external training host, or within the application.). +- Training/validation/testing dataset description. +- Instructions for data pre-processing (e.g. normalization). +- Configuration of hyperparameters, etc. + +For example, the technician can configure the training host in the SMO/Non-RT RIC to use datasets collected from dense urban area for AI/ML training, to obtain a specialized AI/ML application (or model) for metropolitan area deployment. + +A technician can request and/or subscribe status reporting of a specific training process. The reporting configuration message can contain: + +- The ID for the AI/ML training process. +- Reporting periodicity. +- Reporting time period. +- Reporting objects (e.g., training progress indicator, training performance indicator, etc.). +- Event-trigger conditions. +- Maximum number of reports, etc. + +Based on the training status reports, a technician can send commands to intervene the training process. For example, a technician can terminate a training process, if the reporting shows the training is diverging or the training of another candidate App/model is completed. A technician can initiate a new training process after hyperparameter re-configuration. + +The Human-Machine termination converts external messages from technicians to internal message formats used by the training host and/or rApps. External messages include AI/ML training configuration, reporting configuration/request, and human commands on AI/ML training operation (e.g., terminating/initiating a training process, publishing a trained model, etc.). The Human-Machine termination converts the internal training status reports from the training host and/or rApps to outgoing messages to a technician. + +Note: The exact contents of AI/ML training configuration, status requests/reports, and commands are FFS. + +Figure 3.1-3 shows the connection between the Human-Machine interface termination and the technician + +![Diagram showing the connection between a Local Craft Terminal and Human-Machine Termination via a Human-Machine Interface.](45e184e347ffea283483eb74782ca985_img.jpg) + +``` + +graph LR + LCT[Local Craft Terminal] <-->|Human-Machine Interface| HMT[Human-Machine Termination] + +``` + +Diagram showing the connection between a Local Craft Terminal and Human-Machine Termination via a Human-Machine Interface. + +Figure 3.1-3: External Human-Machine termination + +## 3.2 A1 Functionalities + +### 3.2.1 A1-P functionalities + +A1-P functionalities include: + +- Hosting A1 policy and policy type repository. +- Processing queries from rApps on Near-RT RIC supported A1 policy types. +- Maintaining A1 policy enforcement status. +- Notifying rApps about an A1 policy enforcement status. + +### 3.2.2 A1-EI functionalities + +Some of the A1-EI functionalities include: + +- Processing subscription requests for EI from the Near-RT RIC. +- Routing EI to the near-RT RIC in response to subscription requests for that EI. +- Performing EI Job Control. + +### 3.2.3 A1-ML functionalities + +Potential A1-ML functionalities may include: + +- Enabling an AI/ML workflow function to register for the A1-ML service and exchange messages with the Near-RT RIC. +- Routing A1-ML service requests/responses and subscriptions/notifications between the Near-RT RIC and registered AI/ML workflow functions. + +Note: A1-ML service details are FFS. + +## 3.3 AI/ML Functionalities + +AI/ML Functionalities include Non-RT RIC Framework inherent or implementation variability functionalities to support the whole AI/ML lifecycle. + +### 3.3.1 ML Training + +The ML training functionality allows the training of AI/ML models [11] of 3rd party applications (for example, rApps or xApps) within the SMO/Non-RT RIC. The inputs consist of training data and ML model. The training data can be composed of the data collected from Near-RT RIC and O-CU/O-DU over O1 interface, external enrichment information + +over external EI interface, and registered data output from rApps over R1 interface. The input ML model is described by the AI/ML model descriptor/metadata, which can be included in an Application package. This functionality also allows the update/re-training of ML models stored in the ML model repository functionality. + +Note: Details of an AI/ML model descriptor/metadata (format, content, etc.) is FFS. Refer to Annex A.2 in [11] for examples of ML model descriptors. + +The output is a trained, validated, and tested ML model, which is ready to be deployed within an rApp or xApp and which can be stored by the SMO or by the Non-RT RIC Framework using the ML model repository functionality. + +The ML training in the SMO/Non-RT RIC offers offline training. Note: using the ML training in the SMO/Non-RT RIC for online training, e.g., to support online reinforcement learning, is FFS. + +Note: it does not preclude the option that a 3rd party application (for example, rApp or xApp) performs online learning by itself (e.g., a reinforcement learning application). + +The ML training is an “implementation variable” functionality. In the functional view of the Non-RT RIC architecture, it can be realized as an ML Training host function as part of the AI/ML Workflow functions. + +### 3.3.2 ML Model Repository Functionality + +The ML Model Repository functionality allows to store trained ML models and offers the following services to manage them: + +- ML model registration: A service consumer sends a trained ML model, which can be identified by a model identifier (e.g., ModelId), and it is stored with an initial version number. +- ML model update: A service consumer updates a stored ML model. Multiple versions of a model can be stored with version numbers, e.g., for tracking purposes. +- ML model retrieval: A service consumer retrieves a ML model, providing the model identifier and the version number. +- ML model deletion: A service consumer deletes a version of a stored ML model. +- ML model deregistration: A service consumer deregisters a stored ML model, i.e., all stored versions of the model are removed. + +A service consumer can provide additional supplemental information for a ML model version when it registers or updates a ML model. For example, supplemental information can include the performance of the ML model, which helps consumers to select the right model version to be retrieved. Details of the supplemental information (format, content, etc.) is FFS. Note that a service consumer needs SMO/Non-RT RIC’s authorization to use the services, including reading/writing the stored ML models and associated supplemental information. SMO/Non-RT RIC may decide to only partially expose supplemental information of stored models to a service consumer. + +Examples of service consumer include: the ML training host in the SMO/Non-RT RIC, ML training host in the Near-RT RIC, the external AI/ML server (over external AI/ML interface), etc. + +Note: The interface to be used for ML model transfer between the ML model repository functionality and the Near-RT RIC is FFS. + +A ML model can be continuously and incrementally updated/re-trained with online information, however, there is no guarantee that the updated model always leads to better RAN performance. Therefore, a previously stored ML model, which was proved to be well-performing, can serve as a backup if the running model evolves in the wrong direction. + +The ML model repository is an “implementation variable” functionality. In the functional view of the Non-RT RIC architecture, it can be realized as an ML model repository function as part of the AI/ML Workflow functions. Note: ML model repository does not train ML models, it stores trained models. + +### 3.3.3 AI/ML Monitoring + +AI/ML Monitoring is an essential Non-RT RIC Framework functionality to enable run-time monitoring of AI/ML models which are deployed in Non-RT RIC. These AI/ML models can be provided by multi-vendors. The AI/ML Monitoring as key Non-RT RIC Framework functionality ensures these deployed AI/ML models performing normally as they declared in their agreements or contracts signed between model providers and platform operators. + +Contract based strategy can be applied between model providers with application or service providers. Model providers need sign contracts with the service provider when they onboard their models to the platform provided by the service provider. The contract schema can include following types of information: + +- Model Specification. +- Data Specification. +- Monitoring metrics. +- Policies. +- Feedback mechanism. + +AI/ML monitoring is based on the information defined contract schema to support different models from different vendors. + +The monitoring metrics should be defined based on different types of algorithms. Table 3.3-1 shows some monitoring metrics examples based on different types of algorithms. + +**Table 3.3-1: AI/ML model monitoring metrics examples** + +| Binary classification problems | Multiclass classification problems | Regression classification problems
    Forecasting problems
    | +|---------------------------------------|-------------------------------------------|--------------------------------------------------------------------| +| Area under ROC | Accuracy | R squared | +| True positive rate (TPR) | Weighted True Positive Rate (wTPR) | Proportion explained variance | +| Precision | Weighted False Positive Rate (wFPR) | Root of mean squared error(RMSE) | +| F1-Measure | Weighted recall | Mean absolute error (MAE) | +| Logarithmic loss | Weighted precision | Mean squared error(MSE) | +| False positive rate (FPR) | Weighted F1-Measure | | +| Area under PR | Logarithmic loss | | +| Recall | | | + +Contracts are signed between model providers and service providers, which defines the key information of the model, data, monitoring metrics, etc. A contract example is defined in JSON format below. + +``` +{ + "contract": [ + { + "model_spec": { + "algorithm_type": "binary_classification", + "training_data_label": "risk" + }, + "data_spec": { + "data_type": "numeric" + }, + "monitoring_metrics": { + "Area_under_ROC": true, + "Precision": true, + "Logarithmic_loss": true, + "Recall": true + }, + "policy": { + "policy_id": "hge7kahf84asdf44", + "condition": "fault", + "allow_action": [ + "terminate", + "deploy" + ] + }, + "feedback_mech": { + "feedback_data_location": "object_storage_spec", + "feedback_interval": "12h" + }, + "data_schema": { + "fields": [ + { + "metadata": { + "name": "bandwidth", + "nullable": false, + "type": "string" + } + }, + { + "metadata": { + "name": "throughput", + "nullable": false, + "type": "floating" + } + }, + { + "metadata": { +``` + +``` + +1 }, +2 "name": "delay", +3 "nullable": false, +4 "type": "floating" +5 }, +6 { +7 "metadata": { +8 }, +9 "name": "jitter", +10 "nullable": true, +11 "type": "floating" +12 } +13 ] +14 } +15 } +16 ] +17 } + +``` + +In the functional view of the Non-RT RIC architecture, the AI/ML Monitoring can be realized as an AI/ML Monitoring function within the Non-RT RIC Framework. + +## 3.4 R1 Services + +The R1 interface (depicted in Figure 3.4-1) is comprised of a collection of services, hereafter referred to as R1 services, that facilitate the interactions between rApps and the Non-RT RIC framework. + +### 3.4.1 General Description + +As described earlier, the Non-RT RIC is comprised of Non-RT RIC Framework and Non-RT RIC Application (rApp) functional layers which capabilities are offered for consumption and usage through the R1 services. Such services include, but are not limited to: + +- Integration services, including service registration and discovery services, service authentication and authorization services and communication support services. +- Data management and exposure services. +- A1-related services. +- AI/ML workflow services. +- O1-related services. +- O2-related services. + +NOTE: The services listed above may be used on other O-RAN-defined interfaces as well. + +![Figure 3.4-1: R1 interface as a collection of services between the Non-RT RIC Framework and rApps. The diagram shows a Non-RT RIC box at the top containing rApps. Below rApps is a row of service icons: Integration services (registration, discovery, authentication, authorization, ...), O1-related services, O2-related services, Data management and exposure services, A1-related services, AI/ML Workflow services, and Other services. These services are connected to a Non-RT RIC Framework box at the bottom. The framework is divided into two sections: Implementation variable functionalities (yellow) and Inherent Non-RT RIC functionalities (blue). The entire interface is labeled R1.](28eae84d96d7831d9108238f3c0d8873_img.jpg) + +Figure 3.4-1: R1 interface as a collection of services between the Non-RT RIC Framework and rApps. The diagram shows a Non-RT RIC box at the top containing rApps. Below rApps is a row of service icons: Integration services (registration, discovery, authentication, authorization, ...), O1-related services, O2-related services, Data management and exposure services, A1-related services, AI/ML Workflow services, and Other services. These services are connected to a Non-RT RIC Framework box at the bottom. The framework is divided into two sections: Implementation variable functionalities (yellow) and Inherent Non-RT RIC functionalities (blue). The entire interface is labeled R1. + +Figure 3.4-1: R1 interface as a collection of services between the Non-RT RIC Framework and rApps + +### 3.4.2 General Principles + +As described in section 5.2 of [11], at least some ML applications may profitably be deployed either to the Non-RT RIC, to the Near-RT RIC, or to both. This is certainly not true for all ML applications, as the same interfaces are not available in both platforms (e.g., E2, A1 downstream) nor do each have the same real-time requirements. However, for the types of interactions needed by the application types for which such portability would be beneficial, the design choices of the R1 interface should not unnecessarily become an obstacle for such portability. + +- Leverage Existing Work: Because rApps will share some common functionality with xApps (startup, messaging, data sharing, etc.), the prior work done for xApps should be analyzed for applicability to the R1 use cases and leveraged where appropriate. +- Aligned integration services: Because integration or enablement services (such as registration, discovery, authorization, authentication, etc.) are needed to integrate rApps with the Non-RT RIC as well as to integrate xApps with the Near-RT RIC, the work done for xApp integration/enablement should be analyzed for applicability to rApp integration/enablement and leveraged where appropriate. +- Behavioral Alignment Where Practical: Because at least some ML applications will be deployable to the Non-RT RIC, Near-RT RIC, or both, the design choices made for R1 interactions should strive to minimize the refactoring needed of an rApp to enable deployment into a Near-RT RIC environment. +- Decoupled Interface: Although rApps will share some common functionality with xApps, they will also have many unique functionalities and needs that are not applicable to the Near-RT RIC. Therefore, the analysis and design choices made for the R1 interface should be done in parallel and not considered dependent on that of xApps. +- The R1 interface is the sole interface between an rApp and the functionality of the Non-RT RIC and SMO. Therefore, the R1 interface should be defined to meet all functional needs of rApps, with appropriate interface extensibility capabilities as needed. + +The R1 interface will provide a level of abstraction between rApps that are consumers of data and their data sources: + +- The R1 interface will provide functionality such that an rApp that is a consumer of data will not need to know the data needs or data capabilities of the producer of that data service. +- The R1 interface will provide functionality such that an rApp that is a producer of data will not need to know whether there exists one or multiple consumer rApps for that data, or the nature of that consumer (e.g., an rApp versus an entity external to the Non-RT RIC or SMO). +- The R1 interface will provide functionality such that an rApp that is a consumer of data will not need to know whether the data source is local (e.g., an rApp) or remote (e.g., an external data source such as O1). +- The R1 interface will provide functionality such that an rApp that is a consumer of data will not need to know whether the data was the product of a single entity (e.g., rApp), or the combined output of a complex chain of entities (e.g., a chain of rApps each consuming the value-added product of another). +- The Non-RT RIC Framework will not need to understand the semantic meaning of data or the internal structure thereof in order to provide its R1 data registration and data subscription services. + +For example, the data registration and data subscription processing of the Non-RT RIC Framework should be the same irrespective of whether the Non-RT RIC Framework understands the semantic meaning and the internal structure of the data type (as perhaps it might for standardized data types, such as O1) or not (e.g., in the case of rApp-produced data that is not standardized). + +### 3.4.3 Data Management and Exposure Services + +#### 3.4.3.1 R1 Security considerations + +Void + +#### 3.4.3.2 Data Registration Services + +This set of services is used in the setup of data routing paths between rApps and their data sources. + +“Data Registration” functionality allows an rApp to communicate information about the data types that it consumes and produces to the Non-RT RIC Framework. Data registration interactions occur when an rApp is deployed on the Non-RT RIC Framework, and can be re-initiated by either entity thereafter as conditions change in the Non-RT RIC Framework. + +Note that “data registration” interactions are different than “data subscription” interactions in that “data registration” involves only data types and their periodicity, whereas “data subscription” involves specific sets of data within a given “scope”.1 Thus, the purpose of “data registration” interactions is to enable the Non-RT RIC Framework to facilitate data type level value-added services, such as: + +- Authorizing an rApp to produce data of a certain data type. For example, a service provider may want to enforce a policy that two separate rApp instances should not produce the same data type within the same Non-RT RIC Framework instance. +- Authorizing an rApp to consume data of a certain data type. For example, a service provider may want to restrict the availability of certain data types, such as data types that relate to sensitive data. +- Accounting for the number of rApp consumers that exist for a given data type. For example, licensing of certain data-producing rApps may be sensitive to the number of consumer instances of that data type. + +As part of registration processing, the Non-RT RIC Framework will match the needs of data type consumers against the capabilities of data type producers. A valid data type producer for matching purposes would include previously registered + +1 See “Data Subscription Services” section for more information. + +rApp instances that have communicated during their own registration processing that they produce the data type desired for consumption, as well as other data sources, such as O1. For shorthand purposes, a valid data source that the Non-RT RIC Framework is aware of will be referred to in this document as a “known” data source. + +Note: Whether deployment-time data registration interactions precede or follow rApp application configuration and/or activation is TBD. + +As part of data registration interactions, the rApp will first communicate to the Non-RT RIC Framework the data types that it consumes, and then communicate the data types that it produces. This sequence is important to maintain, because the data types that an rApp is capable of producing in some cases will depend on the availability of data types that it desires to consume. The Non-RT RIC Framework will match rApp data type consumption needs against known data sources. In many cases the data type consumed will be standard RAN O1 data. + +As part of its data registration functionality, the Non-RT RIC Framework might also perform some added value functionality such as: + +- Keeping track of the number of rApp data consumers per data type and data source (e.g., for licensing or accounting purposes). +- Ensuring that there is no more than one producer, within a Non-RT RIC instance, of a given data type, or if there are multiple producers, verifying at data subscription-time that the two entities produce data corresponding to different “scopes” (e.g., geography or time). + +The Non-RT RIC Framework will inform the rApp if no corresponding source can be matched to an rApp’s “consumed data” requirements. + +Only the rApp itself knows whether a data source is critical to the proper functioning of that application. Thus, it would be inappropriate for the Non-RT RIC Framework to fail registration processing due to a lack of data source. However, it is useful to have the Non-RT RIC Framework inform the rApp that a source cannot be found for one of its data type inputs, because the lack of a data input could, as noted above, affect the data type(s) the rApp is capable of producing. The rApp would determine how to react given that the data source is unknown: continue with the registration interactions or fail the registration. + +Note that a source of missing data could be found later, such as when an rApp later initiates data registration interactions declaring its ability to produce that data type. To handle such a case, the design of the R1 interface can avoid requiring an rApp to re-declare its desire to consume that data type by having the Non-RT RIC Framework use an anonymous pub/sub paradigm to set up a routing rule for a data consumer rApp, even though no known source of this data currently exists. With such an approach, the Non-RT RIC Framework need only inform the previously registered rApp that the data type with a previously unknown data source now has a known data source. This interaction would inform the rApp that data subscription requests can now be initiated for that data type. + +Of course, the presence of a “new” data source may enable the previously registered rApp to produce a data type that it previously could not due to lack of critical input data. Thus, it is necessary that an rApp be allowed to initiate R1 data registration interactions with the Non-RT RIC Framework even after initial deployment. + +Just as rApp data registration can result in new data-consumption potential for rApps that have previously registered, so too can the deletion of an rApp result in the loss of data-consumption potential for previously registered rApps. This possibility requires that the Non-RT RIC Framework also be able to inform a previously registered rApp that a data type with a previously known data source now has an unknown data source. Because that data source may be a critical data source for the previously registered rApp in producing its own data type, it is necessary that an rApp be able to initiate R1 data registration interactions, even after initial deployment, to notify the Non-RT RIC Framework that it will no longer be producing a particular data type. + +#### 3.4.3.3 Data Subscription Services + +This set of services is used in the request of specific data instances, and the fulfilment thereof by the Non-RT RIC Framework. The subscriber indicates the data type and periodicity thereof being subscribed to (which must be a previously registered “consumed” data type) and a “scope”. A “scope” declaration specifies the filter criteria applied to the “subject” of the data, such as a particular set of RAN network function instances and/or UEs being reported on. + +The Non-RT RIC Framework determines whether the requested data is already locally available, or if (as in the case of RAN data) it needs to interact with an external data source (perhaps via the SMO) to obtain that data. The Non-RT RIC Framework relieves the data source of the burden of having to keep track of the number of data subscribers and mediating multiple subscribers to the same data stream. + +### 3.4.4 Integration Services + +The Non-RT RIC Framework is responsible for producing a collection of Integration Services to assist the service producers and consumers, including, but not limited to: + +- Authentication of service producers and consumers. +- Authorization of service producers and consumers. +- Means for service producers to register/deregister the produced services, and to update the information in case of changes of the service availability. +- Means to notify the changes of the service availability to subscribed consumers. +- Discovery of available services. +- Information about available communication mechanisms (aka transports). + +The Non-RT RIC Framework also comprises a communication support for the service consumers and producers to interact with each other. Nonetheless, a service producer may incorporate its own communication mechanism, so that a producer and a consumer can interact directly via that custom transport mechanism. + +## 3.5 rApp Supporting Functions + +Void + +## 3.6 Other “Implementation Variable” Functions + +Void + +# --- 4 Requirements + +## 4.1 R1 Interface Requirements + +### 4.1.1 Non-RT RIC Framework Requirements + +The following requirements pertain to the Non-RT RIC Framework functionality in support of the R1 interface. + +#### 4.1.1.1 Non-RT RIC Framework Data Registration Services Requirements + +This section captures requirements on data registration interactions between the rApp and the Non-RT RIC Framework. + +| | | +|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRfW-R1r-10] | The Non-RT RIC Framework shall support the capability to engage in ‘data registration’ interactions, via the R1 interface, with an rApp instance that has been newly deployed to that Non-RT RIC Framework. | +|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRfW-R1r-30] | The Non-RT RIC Framework shall have the capability to match rApp data consumption needs against known rApp data sources, setting up routing between a data source rApp and data type consumer rApp. | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Ref: AIML requirement REQ-Non-RT RIC-FUN7. + +| | | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRfW-R1r-40] | The Non-RT RIC Framework shall recognize certain standard data types as having O1 as their known data source, that data source being provided as functionality inherent to the SMO. The Non-RT RIC Framework shall interact as necessary with the SMO to determine whether to consider a particular O1 data type as being available in a specific SMO implementation. A data type that was previously communicated as ‘produced’ by an rApp in a prior data registration interaction shall be considered a ‘known’ data type to the Non-RT RIC Framework. | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Note: For example, a particular SMO implementation may not yet support a particular O1 data type, or a particular Service Provider may have disabled a particular O1 data type. In order for an O1 data type to be considered “known” it must be available within the context of the given SMO implementation and Service Provider environment. + +Note that there is no expectation that data produced by rApps is in any way standardized, nor that the Non-RT RIC Framework must understand the semantic meaning or the internal structure of the data produced by rApps in order for that data type to be considered “known”. + +| | | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRfW-R1r-60] | In response to receipt of a consuming rApp’s R1 data type request, the Non-RT RIC Framework shall set up the consuming routing rule for that data type to the rApp even if no “known” data source can be found. | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRfW-R1r-70] | The Non-RT RIC Framework shall be capable of communicating to the R1 consumer rApp whether that rApp’s data consumption needs can or cannot be fulfilled by a ‘known’ data source. | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Ref: AIML requirement REQ-Non-RT RIC-FUN7. + +rApps may add to the set of data that they consume or produce, for example due to environmental changes (e.g., notification of new produced data type availability). + +| | | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRfW-R1r-90] | The Non-RT RIC Framework shall allow an rApp to initiate registration interactions declaring new data types consumed or produced, even after initial deployment. | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRfW-R1r-100] | When an rApp interacts with the Non-RT RIC Framework to communicate a “produced” data type, the Non-RT RIC Framework shall determine whether there is already a data type routing rule for a registered consumer of that data type. If so, the Non-RT RIC Framework shall send a notification | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|--|-------------------------------------------------------------------------------------------------------------------------| +| | to that consuming rApp informing it that a data type with a previously unknown data source now has a known data source. | +|--|-------------------------------------------------------------------------------------------------------------------------| + +The Non-RT RIC Framework may need to delete from the “known” data sources for a given data type, for example due to removal of a producing rApp. + +| | | +|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRfW-R1r-110] | When the Non-RT RIC Framework detects that an rApp is being undeployed, it shall conclude that any data types being produced by that rApp must be rescinded. It shall determine whether the data source of that data type must now be considered “unknown”. | +|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +When a produced data type’s source is rescinded, it may have ripple effects on any consuming rApps. The Non-RT RIC Framework will communicate to the consuming rApps of a data type when its source is being rescinded. + +| | | +|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRfW-R1r-120] | When the data source for a data type transitions from “known” to “unknown”, the Non-RT RIC Framework shall determine whether there are any registered consumers of that data type. If so, the Non-RT RIC Framework shall send a notification to that consuming rApp informing it that a currently known data source is being removed. | +|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +### 4.1.2 rApp Requirements + +#### 4.1.2.1 rApp Data Registration Service Requirements + +The following requirements pertain to the rApp functionality in support of the R1 interface. + +| | | +|----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRApp-R1r-20] | Deployed rApp instances shall be able to communicate via the R1 interface information relating the data type(s) and periodicity thereof that the rApp consumes and produces, in that sequence. | +|----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Ref: AIML requirement REQ-Non-RT RIC-FUN6. + +| | | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRApp-R1r-30] | An rApp that receives, as part of its data registration interactions, an indication that no corresponding data source can be found for a “consumed” data type shall be responsible for determining whether it can continue functioning without that data type or not. | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Ref: AIML requirement REQ-Non-RT RIC-FUN7. + +| | | +|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-nRTRApp-R1r-40] | An rApp shall be able to interrupt data registration interactions, including after having received an indication that its data consumption needs cannot be fulfilled for some data type. An rApp that has done so shall not continue with data registration processing. | +|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Note: If an rApp does not interrupt its data registration processing after having been informed that no corresponding data source can be found for a “consumed” data type, it is understood that the rApp has functionality to perform runtime processing, perhaps with reduced functionality, in the absence of that data source. + +When a data type with a known data source is rescinded, it may have ripple effects on any consuming rApps. The same is true when a new data source becomes available for a data type with a previously unknown data source. It is the + +responsibility of each affected rApp to determine how the lack of a data source, or the addition of a data source, impacts that rApp's processing. + +[REQ-nRTRApp-R1r-50] + +When an rApp is informed that the ability to fulfill that rApp's data consumption needs has changed, it is the responsibility of that rApp to determine how to accommodate that change. + +Note: For example, any need for graceful termination of current execution threads will be the responsibility of the rApp. + +# Annex A (Informative): Non-RT RIC Processing Examples + +Because examples can be useful in promoting understanding, this Annex provides examples to illustrate the concepts described in the main document. + +## A.1 Introduction to Illustrative Example + +We will make use of the following fictitious rApps in some of the subsequent sections of this Annex. In this illustration, there are three separate rApps that execute in a given Non-RT RIC Framework instance. + +- rApp “R” – An RF signal predictor. This rApp consumes RAN (O1) measurements of the actual RF signal experienced by a UE for its serving and neighbor cells ( $RFa_{n,s}$ ) as well as other measurements useful in determining that UE’s actual location ( $La$ ). This rApp’s role is to output a future time (e.g., $t = 10$ seconds) prediction of the location of that UE ( $Lp^t$ ) as well as a prediction of the RF signal that will at that location be experienced by that UE for its serving and neighbor cells ( $RFp^t_{n,s}$ ). +- rApp “U” – A cell utilization predictor. This rApp consumes RAN (O1) cell utilization measurements regarding the actual capacity utilization for a given cell site ( $CUa$ ) over time. This rApp’s role is to trend that input so as to allow it to output a future time (e.g., $t = 60$ minutes) prediction of that cell site’s utilization ( $CUp^t$ ). +- rApp “Q” – A UE QoE predictor. This rApp consumes measurements regarding a UE’s RF signal (either an actual RAN measurement or a future time prediction) as well as a measurement of a cell site’s capacity utilization (either an actual RAN measurement or a future time prediction). This rApp’s role is to calculate the QoE experienced by that UE. Thus, this rApp can: + - Estimate the actual QoE currently being experienced by a UE ( $Qa_s$ ), by consuming measurements of the actual RF signal currently experienced by that UE relative to its serving cell ( $RFa_s$ ) along with the actual cell utilization of that serving cell ( $CUa$ ). + - Estimate the QoE that a UE would experience were it currently connected instead to a neighbor cell ( $Qp_n$ ), by consuming measurements of the actual RF signal currently experienced by that UE relative to that neighbor cell ( $RFa_n$ ) along with the actual cell utilization of that neighbor cell ( $CUa$ ). + - Estimate the QoE that will be experienced by a UE at a future time ( $t$ ) assuming that UE will remain connected to its serving cell ( $Qp^t_s$ ), by consuming future time ( $t$ ) predicted measurements of the RF signal that will be experienced by that UE relative to its serving cell ( $RFp^t_s$ ), along with the future time ( $t$ ) predicted cell utilization of that serving cell ( $CUp^t$ ). + - Estimate the QoE that would be experienced by a UE at that future time if that UE were to be connected instead to a neighbor cell ( $Qp^t_n$ ), by consuming future time ( $t$ ) predicted measurements of the RF signal that would be experienced by that UE relative to that neighbor cell ( $RFp^t_n$ ), along with the future time ( $t$ ) predicted cell utilization of that neighbor cell ( $CUp^t$ ). + +These data source relationships can be seen in Figure A.1-1 below. For the purposes of this section we need not specify what will be done with QoE measurements output by rApp Q, rather leaving it unstated for other sections of this document to build on this example. For now we merely point out that multiple options exist, both local (e.g., another rApp consuming the QoE measurement to determine an action to take across A1 or O1) and remote (e.g., the Non-RT RIC Framework forwarding the QoE measurement to a Near-RT RIC via A1-EI for use by some xApp). + +![Figure A.1-1: Example rApp Data Sources. The diagram shows three rApps (R, U, Q) interacting with a Non-RT RIC Framework. rApp R sends RFa_{n,s}, La, and RfP_{n,s} to the framework, and receives Lp. rApp U sends CUa and CUpt. rApp Q sends RFa_{n,s}, RfP_{n,s}, CUa, CUpt, Qa_s, Qp_n, Qp_s, and Qp_n^i. The framework sends RFa_{n,s}, La, and CUa to SMO Inherent Functionality (O1). The entire system is labeled R1 and Non-RT RIC.](3eca52b55e75e56f3cbe39a63c7f66e7_img.jpg) + +Figure A.1-1: Example rApp Data Sources. The diagram shows three rApps (R, U, Q) interacting with a Non-RT RIC Framework. rApp R sends RFa\_{n,s}, La, and RfP\_{n,s} to the framework, and receives Lp. rApp U sends CUa and CUpt. rApp Q sends RFa\_{n,s}, RfP\_{n,s}, CUa, CUpt, Qa\_s, Qp\_n, Qp\_s, and Qp\_n^i. The framework sends RFa\_{n,s}, La, and CUa to SMO Inherent Functionality (O1). The entire system is labeled R1 and Non-RT RIC. + +**Figure A.1-1: Example rApp Data Sources** + +We will use sequence diagrams to illustrate the interactions using this example. In so doing, we will use the following actors: + +- Non-RT RIC Inherent Functions: This actor will be chosen for the termination of an interaction when the associated functionality is inherent to the Non-RT RIC Framework. +- SMO Inherent Functions: This actor will be chosen for the termination of an interaction when the associated functionality is decidedly not part of the Non-RT RIC functional space, i.e., neither part of the Non-RT RIC Framework nor part of an rApp. +- Implementation Variable Functions: This actor will be chosen for the termination of an interaction when the associated functionality can be optionally considered part of the Non-RT RIC Framework, or not, in any given implementation. + +## A.2 R1 Processing Examples + +### A.2.1 R1 Data Registration Services Examples + +R1 “data registration” refers to the set of functionality through which the Non-RT RIC Framework provides a set of data mediation services to the rApps, and the rApps provide a set of data production services to the Non-RT RIC Framework. The rApp will first communicate to the Non-RT RIC Framework the data that it consumes, and then communicate the data that it produces. + +``` +@startuml +Autonumber +skinparam defaultFontSize 30 +Autonumber + +Participant SMO as "SMO Inherent\nFunctions" +Participant ImpVar as "Implementation\nVariable\nFunctions" +Participant NRTR as "Non-RT RIC\nInherent\nFunctions" + +Group Data Registration + Group Interactions: rApp as Data Consumer + Note over SMO, NRTR +``` + +``` + + The rApp communicates over the R1 interface the data types that it consumes. + End Note + + End + + Group Interactions: rApp as Data Producer + + Note over SMO, NRTR + The rApp communicates over the R1 interface the data types that it produces. + End Note + + End + + End + +@enduml + +``` + +![Figure A.2-1: Data Registration Interaction Summary. The diagram shows a central box divided into two main sections: 'Interactions: rApp as Data Consumer' and 'Interactions: rApp as Data Producer'. Above and below these sections are three boxes: 'SMO Inherent Functions', 'Implementation Variable Functions', and 'Non-RT RIC Inherent Functions'. The central box contains two yellow-highlighted text blocks: 'The rApp communicates over the R1 interface the data types that it consumes.' and 'The rApp communicates over the R1 interface the data types that it produces.'](4d99ea38aa306bbdb00e5ccefc493772_img.jpg) + +Figure A.2-1: Data Registration Interaction Summary. The diagram shows a central box divided into two main sections: 'Interactions: rApp as Data Consumer' and 'Interactions: rApp as Data Producer'. Above and below these sections are three boxes: 'SMO Inherent Functions', 'Implementation Variable Functions', and 'Non-RT RIC Inherent Functions'. The central box contains two yellow-highlighted text blocks: 'The rApp communicates over the R1 interface the data types that it consumes.' and 'The rApp communicates over the R1 interface the data types that it produces.' + +**Figure A.2-1: Data Registration Interaction Summary** + +As described earlier, the Non-RT RIC Framework will match rApp data consumption needs against known data sources. In many cases the data consumed will be standard RAN O1 data. + +To illustrate this, assume that rApp “R” is deployed first into the Non-RT RIC execution environment. This rApp would initiate R1 data registration interactions to declare that it consumes as input the RAN data types $RFa_{n,s}$ and $La$ . Because these are O1 data types, the Non-RT RIC Framework would know that it must look to the SMO (inherent functionality) as their data source. Thus, the Non-RT RIC Framework will reply to rApp “R” that the source for these data types is known. + +At some point after the data registration interactions, rApp “R” would initiate a formal “subscription” request with specific “scope” information (including the specific UEs or a class thereof from which to collect that input). Only then would the Non-RT RIC Framework (working with the SMO as necessary) start providing actual data measure instances. This “subscription” interaction will be discussed in a subsequent section. + +As part of its continued data registration processing, rApp “R” would declare that it produces measure $Lp'$ , a future time prediction of the location of a UE, as well as produce data type $RFp'_{n,s}$ , a future time prediction of RF signal at a UE’s serving and neighbor cells.2 + +2 Alternately the data type could be defined such that the neighbor and serving cell discriminators are understood as “scope” information and left out of the registration interaction. With this approach, the data type would be represented as $RFp'$ , and a “scope” parameter at data subscription time would indicate the cell type, “serving” or “neighbor”, of interest. + +The above can be seen represented in the sequence diagrams below. + +``` + +@startuml +skinparam defaultFontSize 30 +Autonumber + +Participant NRTR as "Non-RT RIC\nInherent\nFunctions" +Participant rAppR as "rApp R" + +Group Data Consumer Interactions + +Group In Parallel: Consumed Data Type 1 + +rAppR -> NRTR: Register Data Type RFa(n,s) as Consumed. +NRTR -> NRTR: Determine SMO as data source for\ndata type RFa(n,s). +NRTR -> NRTR: Set up anonymous routing rule for SMO\nas producer for data type RFa(n,s). +NRTR -> NRTR: Set up anonymous routing rule to rApp R\nas consumer for data type RFa(n,s). + +End + +Group In Parallel: Consumed Data Type 2 + +rAppR -> NRTR: Register Data Type La as Consumed. +NRTR -> NRTR: Determine SMO as data source for\ndata type La. +NRTR -> NRTR: Set up anonymous routing rule for SMO\nas producer for data type La. +NRTR -> NRTR: Set up anonymous routing rule to rApp R\nas consumer for data type La. + +End + +End + +Note over NRTR, rAppR + Note that all "consumed" data type interactions must complete prior to initiating + "produced" data type interactions. This is because an rApp only knows what it + can produce once it knows what data is available to it. +End Note + +Group Data Producer Interactions + +Group In Parallel: Produced Data Type 1 + +rAppR -> NRTR: Register Data Type Lp(t) as Produced. +NRTR -> NRTR: Set up anonymous routing rule from rApp R\nas producer for data type Lp(t). + +End + +Group In Parallel: Produced Data Type 2 + +rAppR -> NRTR: Register Data Type RFp(t)(n,s) as Produced. +NRTR -> NRTR: Set up anonymous routing rule from rApp R\nas producer for data type RFp(t)(n,s). + +End + +Note over NRTR, rAppR + Note that at this time there are producer routing rules for + both La(t) and RFp(t)(n,s) with no corresponding consumer. +End Note + +End + +@enduml + +``` + +![Sequence diagram showing Data Consumer and Data Producer interactions between Non-RT RIC Inherent Functions and rApp R.](47276ce5937744509087208ef7ec3a87_img.jpg) + +The diagram illustrates the data registration interactions between the Non-RT RIC Inherent Functions and rApp R. It is divided into two main sections: Data Consumer Interactions and Data Producer Interactions. + +**Data Consumer Interactions:** + +- In Parallel: Consumed Data Type 1** + - 1 Register Data Type RFa(n,s) as Consumed. + - 2 Determine SMO as data source for data type RFa(n,s). + - 3 Set up anonymous routing rule for SMO as producer for data type RFa(n,s). + - 4 Set up anonymous routing rule to rApp R as consumer for data type RFa(n,s). +- In Parallel: Consumed Data Type 2** + - 5 Register Data Type La as Consumed. + - 6 Determine SMO as data source for data type La. + - 7 Set up anonymous routing rule for SMO as producer for data type La. + - 8 Set up anonymous routing rule to rApp R as consumer for data type La. + +Note that all "consumed" data type interactions must complete prior to initiating "produced" data type interactions. This is because an rApp only knows what it can produce once it knows what data is available to it. + +**Data Producer Interactions:** + +- In Parallel: Produced Data Type 1** + - 9 Register Data Type Lp(t) as Produced. + - 10 Set up anonymous routing rule from rApp R as producer for data type Lp(t). +- In Parallel: Produced Data Type 2** + - 11 Register Data Type RFp(t)(n,s) as Produced. + - 12 Set up anonymous routing rule from rApp R as producer for data type RFp(t)(n,s). + +Note that at this time there are producer routing rules for both La(t) and RFp(t)(n,s) with no corresponding consumer. + +Sequence diagram showing Data Consumer and Data Producer interactions between Non-RT RIC Inherent Functions and rApp R. + +**Figure A.2-2: First Illustrative Example - rApp R Data Registration Interactions** + +The Non-RT RIC Framework would return a registration-time warning to the rApp if no corresponding source can be matched to an rApp's "consumed data" requirements. The rApp would determine how to react given that the data source is unknown: continue with the registration interactions or fail the registration. + +The Non-RT RIC Framework might also perform some registration-time added value validations such as: + +- Keeping track of the number of rApp data consumers per data type and data source (e.g., for licensing or accounting purposes). +- Ensuring that no other entity also produces data type $RFp'_{n,s}$ , or if they do verifying at data subscription-time that the two entities produce data corresponding to different “scopes” (e.g., geography or time). + +We will illustrate the above considerations by extending our example, assuming that rApp “Q” is next deployed to the execution environment. This rApp would initiate R1 data registration interactions to declare that it consumes as input data sources $RFa_{n,s}$ , $RFp'_{n,s}$ (alternately $RFp'$ , see footnote above), $CUa$ and $CUp'$ . Because the data source of $RFa_{n,s}$ and $CUa$ is assumed to be standard O1, these data types would be treated as described above. The Non-RT RIC Framework would also respond that there is a known data source (i.e., rApp “R”) for data type $RFp'_{n,s}$ . However, because rApp “U” had not yet been deployed and registered, the Non-RT RIC Framework would find no source for data type $CUp'$ . + +Note that, as described above, rApp “Q” can produce meaningful output in the absence of $CUp'$ input: $Qa_n$ and $Qa_s$ , though it cannot produce $Qp'_n$ or $Qp'_s$ . Only the rApp itself knows whether a data source is critical to the proper functioning of that application. Thus, it would be inappropriate for the Non-RT RIC Framework to fail registration processing due to a lack of data source $CUp'$ . However, it is useful to have the Non-RT RIC Framework inform the rApp that a source cannot be found for one of its data type inputs, because the lack of a data input could, as in this case, affect the data type(s) the rApp is capable of producing. Because a source of missing data could be found later, the Non-RT RIC Framework would use an anonymous pub/sub paradigm to set up a routing rule for rApp “Q” as a consumer of data type $CUp'$ , even though no known source of this data currently exists. + +These interactions can be seen in the sequence diagram below. + +``` + +@startuml +skinparam defaultFontSize 30 +Autonumber + +Participant NRTR as "Non-RT RIC\nInherent\nFunctions" +Participant rAppQ as "rApp Q" + +Group Data Consumer Interactions + +Group In Parallel: Consumed Data Type 1 + +rAppQ -> NRTR: Register Data Type RFa(n,s) as Consumed. +NRTR -> NRTR: Determine SMO as data source for\ndata type RFa(n,s) +NRTR -> NRTR: Determine that there already exists a routing rule for\nSMO as producer for +data type RFa(n,s) . +NRTR -> NRTR: Set up anonymous routing rule to rApp Q\nas consumer for data type +RFa(n,s) . + +End + +Group In Parallel: Consumed Data Type 2 + +rAppQ -> NRTR: Register Data Type RFP(t)(n,s) as Consumed. +NRTR -> NRTR: Determine rApp R as data source for data type RFP(t)(n,s) . +NRTR -> NRTR: Determine that there already exists a routing rule for\nrApp R as producer +for data type RFP(t)(n,s) . +NRTR -> NRTR: Set up anonymous routing rule to rApp Q\nas consumer for data type +RFP(t)(n,s) . + +End + +Group In Parallel: Consumed Data Type 3 + +rAppQ -> NRTR: Register Data Type CUa as Consumed. +NRTR -> NRTR: Determine SMO as data source for\ndata type CUa +NRTR -> NRTR: Set up anonymous routing rule from SMO\nas producer for data type CUa. +NRTR -> NRTR: Set up anonymous routing rule to rApp Q\nas consumer for data type CUa. + +``` + +``` + +End + +Group In Parallel: Consumed Data Type 4 + +rAppQ -> NRTR: Register Data Type CUp(t) as Consumed. +NRTR -> NRTR: Determine no known data source for data type CUp(t). +NRTR -> rAppQ: Notification that CUp(t) has no known data source. +rAppQ -> rAppQ: Decision to proceed with\nregistration processing. + +Note over NRTR, rAppQ +Because rApp "Q" can perform predictions based on "actuals" and not just future +time predicted values, we will assume that lack of CUp(t) data is no reason to stop +registration processing. Alternately rApp Q could throw an error. +The implication is that the Non-RT RIC Framework will reject any subsequent +Subscription requests for data type CUp(t). +End Note + +NRTR -> NRTR: Set up anonymous routing rule to rApp Q\nas consumer for data type CUp(t). + +End + +Note over NRTR, rAppQ +Note that at this time there is a consumer routing rule for CUp(t) with no +corresponding producer. +End Note + +End + +Group Data Producer Interactions + +Group In Parallel: Produced Data Types + +rAppQ -> NRTR: Register Data Type Qa(s) as Produced. +NRTR -> NRTR: Set up anonymous routing rule from rApp Q\nas producer for data type Qa(s). + +rAppQ -> NRTR: Register Data Type Qp(n) as Produced. +NRTR -> NRTR: Set up anonymous routing rule from rApp Q\nas producer for data type Qp(n). + +End + +Note over NRTR, rAppQ +Because there is no known data source for CUp(t), rApp Q cannot produce data +types Qp(t)(s) or Qp(t)(n). This exemplifies why it is necessary for data +consumer interactions to complete prior to data producer interactions begin. +End Note + +End + +@enduml + +``` + +![Sequence diagram showing interactions between Non-RT RIC Inherent Functions and rApp Q. The diagram is divided into 'Data Consumer Interactions' and 'Data Producer Interactions'. The 'Data Consumer Interactions' section includes four parallel blocks for Consumed Data Type 1, 2, 3, and 4. The 'Data Producer Interactions' section includes one parallel block for Produced Data Types. The diagram shows a flow of steps from 1 to 21, with a decision point at step 16 and a note at step 17.](f5ae098d474fc86f04350919ee56d5f2_img.jpg) + +**Non-RT RIC Inherent Functions** + +**rApp Q** + +**Data Consumer Interactions** + +**In Parallel: Consumed Data Type 1** + +- 1 Register Data Type RFa(n,s) as Consumed. +- 2 Determine SMO as data source for data type RFa(n,s). +- 3 Determine that there already exists a routing rule for SMO as producer for data type RFa(n,s). +- 4 Set up anonymous routing rule to rApp Q as consumer for data type RFa(n,s). + +**In Parallel: Consumed Data Type 2** + +- 5 Register Data Type RFP(t)(n,s) as Consumed. +- 6 Determine rApp R as data source for data type RFP(t)(n,s). +- 7 Determine that there already exists a routing rule for rApp R as producer for data type RFP(t)(n,s). +- 8 Set up anonymous routing rule to rApp Q as consumer for data type RFP(t)(n,s). + +**In Parallel: Consumed Data Type 3** + +- 9 Register Data Type CUa as Consumed. +- 10 Determine SMO as data source for data type CUa. +- 11 Set up anonymous routing rule from SMO as producer for data type CUa. +- 12 Set up anonymous routing rule to rApp Q as consumer for data type CUa. + +**In Parallel: Consumed Data Type 4** + +- 13 Register Data Type CUp(t) as Consumed. +- 14 Determine no known data source for data type CUp(t). +- 15 Notification that CUp(t) has no known data source. +- 16 Decision to proceed with registration processing. + +Because rApp "Q" can perform predictions based on "actuals" and not just future time predicted values, we will assume that lack of CUp(t) data is no reason to stop registration processing. Alternately rApp Q could throw an error. The implication is that the Non-RT RIC Framework will reject any subsequent Subscription requests for data type CUp(t). + +17 Set up anonymous routing rule to rApp Q as consumer for data type CUp(t). + +Note that at this time there is a consumer routing rule for CUp(t) with no corresponding producer. + +**Data Producer Interactions** + +**In Parallel: Produced Data Types** + +- 18 Register Data Type Qa(s) as Produced. +- 19 Set up anonymous routing rule from rApp Q as producer for data type Qa(s). +- 20 Register Data Type Qp(n) as Produced. +- 21 Set up anonymous routing rule from rApp Q as producer for data type Qp(n). + +Because there is no known data source for CUp(t), rApp Q cannot produce data types Qp(t)(s) or Qp(t)(n). This exemplifies why it is necessary for data consumer interactions to complete prior to data producer interactions begin. + +**Non-RT RIC Inherent Functions** + +**rApp Q** + +Sequence diagram showing interactions between Non-RT RIC Inherent Functions and rApp Q. The diagram is divided into 'Data Consumer Interactions' and 'Data Producer Interactions'. The 'Data Consumer Interactions' section includes four parallel blocks for Consumed Data Type 1, 2, 3, and 4. The 'Data Producer Interactions' section includes one parallel block for Produced Data Types. The diagram shows a flow of steps from 1 to 21, with a decision point at step 16 and a note at step 17. + +**Figure A.2-3: First Illustrative Example - rApp Q Data Registration Interactions** + +Continuing this example, if rApp “U” is later deployed to the execution environment of this Non-RT RIC Framework, it would initiate R1 data registration interactions to declare that it consumes as input data type $CUa$ . Because a routing rule already exists for the SMO as the producer of $CUa$ , all that remains is to set up a routing rule for rApp “U” as a consumer of this data type. + +rApp “U” would also declare that it produces data type $CUp'$ . The Non-RT RIC Framework will set up the producing routing rule for rApp “U” as the producer of $CUp'$ data type. In addition, having previously set up the anonymous consuming routing rule of $CUp'$ data to rApp “Q”, the Non-RT RIC Framework will notify rApp “Q” that a known data source now exists. It is up to rApp “Q” to decide how to proceed given this information. + +The following sequence diagram illustrates these interactions. As it is beyond the scope of this section to go into the full set of R1 interactions involved in the deployment of an rApp, the following sequence diagram will only highlight that aspect of rApp U deployment processing that involves the communication of its produced data type $CUp'$ . + +``` + +@startuml +skinparam defaultFontSize 30 +Autonumber + +Participant ImpVar as "Implementation\nVariable\nFunctions" +Participant NRTR as "Non-RT RIC\nInherent\nFunctions" +Participant rAppU as "rApp U" + +Group rApp U Deployment + + Create rAppU + ImpVar -> rAppU: + + Note over NRTR, rAppU + rApp U is deployed to the Non-RT RIC Framework execution environment. + End Note + + ... Full deployment processing TBD ... + +End + +Group Data Consumer Interactions + +rAppU -> NRTR: Register Data Type CUa as Consumed. +NRTR -> NRTR: Determine SMO as data source for\data type CUa. +NRTR -> NRTR: Determine that there already exists a routing rule for\nSMO as producer for\data type CUa. +NRTR -> NRTR: Set up anonymous routing rule to rApp U\nas consumer for data type CUa. + +End + +Group Data Producer Interactions + +rAppU -> NRTR: Register Data Type CUp(t) as Produced. +NRTR -> NRTR: Set up anonymous routing rule from rApp U\nas producer for data type CUp(t). +NRTR -> NRTR: Determine that there already exists a routing rule for\nrApp Q as consumer of data type CUp(t). + +End + +Group Extended Data Consumer Interactions + +NRTR -> rAppQ: Notification that CUp(t) now has a known data source. + +Note over NRTR, rAppQ + +``` + +``` + +1 rApp Q now knows that the Non-RT RIC Framework will no longer reject subsequent +2 Subscription +3 requests for data type CUp(t). It must decide how to proceed. +4 rApp Q determines that it now has all the data dependencies needed to produce +5 additional data types: Qp(t)(s) and Qp(t)(n). +6 End Note +7 +8 rAppQ -> rAppQ: Decision how to proceed +9 +10 End +11 +12 Group Extended Data Producer Interactions: In Parallel +13 +14 rAppQ -> NRTR: Register Data Type Qp(t)(s) as Produced. +15 NRTR -> NRTR: Set up anonymous routing rule from rApp Q\nas producer for data type +16 Qp(t)(s). +17 rAppQ -> NRTR: Register Data Type Qp(t)(n) as Produced. +18 NRTR -> NRTR: Set up anonymous routing rule from rApp Q\nas producer for data type +19 Qp(t)(n). +20 +21 NRTR -> NRTR: Determine if any consumer routing rules for\ndata types Qp(t)(s) or +22 Qp(t)(n). +23 +24 Note over NRTR, rAppQ +25 If there were such consumer routing rule(s),the Non-RT RIC Framework +26 would send a notification to each corresponding consuming rApp notifying +27 that Qp(t)(s) and Qp(t)(n) now have known data sources. This interaction +28 would be equivalent to step 9 shown above. +29 End Note +30 +31 End +32 +33 @enduml + +``` + +![Sequence diagram illustrating rApp U Registration Interactions between Implementation Variable Functions, Non-RT RIC Inherent Functions, rApp U, and rApp Q.](7f70314ff6eec67c0907a33ce1354015_img.jpg) + +The diagram illustrates the registration interactions for rApp U. It is structured into several phases and interaction blocks: + +- Implementation Variable Functions** and **Non-RT RIC Inherent Functions** are the primary actors. +- rApp U Deployment** (Step 1): rApp U is deployed to the Non-RT RIC Framework execution environment. Full deployment processing TBD. +- Data Consumer Interactions**: + - 2 Register Data Type CUa as Consumed. + - 3 Determine SMO as data source for data type CUa. + - 4 Determine that there already exists a routing rule for SMO as producer for data type CUa. + - 5 Set up anonymous routing rule to rApp U as consumer for data type CUa. +- Data Producer Interactions**: + - 6 Register Data Type CUp(t) as Produced. + - 7 Set up anonymous routing rule from rApp U as producer for data type CUp(t). + - 8 Determine that there already exists a routing rule for rApp Q as consumer of data type CUp(t). +- Extended Data Consumer Interactions**: + - 9 Notification that CUp(t) now has a known data source. + - rApp Q now knows that the Non-RT RIC Framework will no longer reject subsequent Subscription requests for data type CUp(t). It must decide how to proceed. + - rApp Q determines that it now has all the data dependencies needed to produce additional data types: Qp(t)(s) and Qp(t)(n). + - 10 Decision how to proceed. +- Extended Data Producer Interactions: In Parallel**: + - 11 Register Data Type Qp(t)(s) as Produced. + - 12 Set up anonymous routing rule from rApp Q as producer for data type Qp(t)(s). + - 13 Register Data Type Qp(t)(n) as Produced. + - 14 Set up anonymous routing rule from rApp Q as producer for data type Qp(t)(n). + - 15 Determine if any consumer routing rules for data types Qp(t)(s) or Qp(t)(n). + - If there were such consumer routing rule(s), the Non-RT RIC Framework would send a notification to each corresponding consuming rApp notifying that Qp(t)(s) and Qp(t)(n) now have known data sources. This interaction would be equivalent to step 9 shown above. + +Sequence diagram illustrating rApp U Registration Interactions between Implementation Variable Functions, Non-RT RIC Inherent Functions, rApp U, and rApp Q. + +Figure A.2-4: First Illustrative Example - rApp U Registration Interactions + +Just as the deployment of an rApp can result in new data-producing potential for previously deployed rApps, the deletion of an rApp can result in the loss of data-producing potential for previously deployed rApps. + +As an example, if rApp “U” were next to be undeployed from the Non-RT RIC Framework, then rApp “Q” would lose its data source for data type $CUp^t$ . This would result in rApp “Q” no longer being able to produce data types $Qp^t_s$ and $Qp^t_n$ . + +As it is beyond the scope of this section to go into the full set of R1 interactions involved in the undeployment of an rApp, the following sequence diagram will only highlight that aspect of rApp “U” undeployment processing that involves the rescinding of its produced data type $CUp^t$ . + +``` + +@startuml +skinparam defaultFontSize 30 +Autonumber + +Participant ImpVar as "Implementation\nVariable\nFunctions" +Participant NRTR as "Non-RT RIC\nInherent\nFunctions" +Participant rAppU as "rApp U" +Participant rAppQ as "rApp Q" + +Group rApp U Undeployment + + ImpVar -> rAppU !! : + + Note over NRTR, rAppU + rApp U undeployment processing begins + End Note + + ... Full undeployment processing TBD ... + +End + +Group Data Producer Interactions + +NRTR -> NRTR: + +Note over NRTR, rAppU + Non-RT RIC Framework determines that Data Type CUp(t) no longer has a known data source +End Note + +NRTR -> NRTR: Delete anonymous routing rule to rApp U\nas producer for data type CUp(t). + +NRTR -> NRTR: Determine that rApp Q has a consumer routing rule for CUp(t) data type. + +Note over NRTR, rAppQ + For the registered target of each consumer routing rule, Non-RT RIC Framework + will determine if there are any active subscriptions for this data type. + Non-RT RIC Framework deletes any subscriptions that rApp Q had to CUp(t) data. +End Note + +End + +Group Extended Data Consumer Interactions + +NRTR -> rAppQ: Notification that CUp(t) is being rescinded as a known data source. + +Note over NRTR, rAppQ + rApp Q now knows that it will no longer have critical data needed to produce its Qp(t)(s) + and Qp(t)(n) measures. + rApp Q is responsible for determining how to proceed in the absence of this data source. + Options include throwing + an error or continuing with reduced functionality. Because rApp "Q" can perform + predictions based on + +``` + +``` +1 "actuals" and not just future time predicted values, we will assume that rApp "Q" will +2 not throw an error. +3 rApp Q is also responsible for determining how to gracefully shut down processing of its +4 in-progress activities in response to the eliminated data source. +5 End Note +6 +7 rAppQ -> rAppQ: Decision how to proceed +8 +9 Group Extended Data Producer Interactions +10 +11 rAppQ -> NRTR: Rescind Data Type Qp(t)(s) as Produced. +12 NRTR -> NRTR: Determine if any consumer routing rule exists for Qp(t)(s) data type. +13 +14 rAppQ -> NRTR: Rescind Data Type Qp(t)(n) as Produced. +15 NRTR -> NRTR: Determine if any consumer routing rule exists for Qp(t)(n) data type. +16 +17 Note over NRTR, rAppQ +18 The pattern above would repeat itself for any registered consumer of these data types. +19 For simplicity we will assume that there are none. +20 End Note +21 +22 End +23 +24 @enduml +``` + +![Sequence diagram illustrating the process of rApp Q rescinding produced data. The diagram shows interactions between Implementation Variable Functions, Non-RT RIC Inherent Functions, rApp U, and rApp Q. Key steps include: 1. rApp U Undeployment (rApp U deployment processing begins, Full undeployment processing TBD). 2. Data Producer Interactions (Non-RT RIC Framework determines that Data Type CUp(t) no longer has a known data source). 3. Delete anonymous routing rule to rApp U as producer for data type CUp(t). 4. Determine that rApp Q has a consumer routing rule for CUp(t) data type. 5. Notification that CUp(t) is being rescinded as a known data source. 6. Decision how to proceed. 7. Rescind Data Type Qp(t)(s) as Produced. 8. Determine if any consumer routing rule exists for Qp(t)(s) data type. 9. Rescind Data Type Qp(t)(n) as Produced. 10. Determine if any consumer routing rule exists for Qp(t)(n) data type. The pattern would repeat itself for any registered consumer of these data types.](54f607a04d2807a2235a11e93fa1b538_img.jpg) + +**Implementation Variable Functions**   **Non-RT RIC Inherent Functions**   **rApp U**   **rApp Q** + +**rApp U Undeployment** + +1 + +rApp U deployment processing begins + +Full undeployment processing TBD + +**Data Producer Interactions** + +2 + +Non-RT RIC Framework determines that Data Type CUp(t) no longer has a known data source + +3 Delete anonymous routing rule to rApp U as producer for data type CUp(t). + +4 Determine that rApp Q has a consumer routing rule for CUp(t) data type. + +For the registered target of each consumer routing rule, Non-RT RIC Framework will determine if there are any active subscriptions for this data type. Non-RT RIC Framework deletes any subscriptions that rApp Q had to CUp(t) data. + +5 Notification that CUp(t) is being rescinded as a known data source. + +rApp Q now knows that it will no longer have critical data needed to produce its Qp(t)(s) and Qp(t)(n) measures. rApp Q is responsible for determining how to proceed in the absence of this data source. Options include throwing an error or continuing with reduced functionality. Because rApp "Q" can perform predictions based on "actuals" and not just future time predicted values, we will assume that rApp "Q" will not throw an error. rApp Q is also responsible for determining how to gracefully shut down processing of its in-progress activities in response to the eliminated data source. + +6 Decision how to proceed + +**Extended Data Producer Interactions** + +7 Rescind Data Type Qp(t)(s) as Produced. + +8 Determine if any consumer routing rule exists for Qp(t)(s) data type. + +9 Rescind Data Type Qp(t)(n) as Produced. + +10 Determine if any consumer routing rule exists for Qp(t)(n) data type. + +The pattern above would repeat itself for any registered consumer of these data types. For simplicity we will assume that there are none. + +**Implementation Variable Functions**   **Non-RT RIC Inherent Functions**   **rApp U**   **rApp Q** + +Sequence diagram illustrating the process of rApp Q rescinding produced data. The diagram shows interactions between Implementation Variable Functions, Non-RT RIC Inherent Functions, rApp U, and rApp Q. Key steps include: 1. rApp U Undeployment (rApp U deployment processing begins, Full undeployment processing TBD). 2. Data Producer Interactions (Non-RT RIC Framework determines that Data Type CUp(t) no longer has a known data source). 3. Delete anonymous routing rule to rApp U as producer for data type CUp(t). 4. Determine that rApp Q has a consumer routing rule for CUp(t) data type. 5. Notification that CUp(t) is being rescinded as a known data source. 6. Decision how to proceed. 7. Rescind Data Type Qp(t)(s) as Produced. 8. Determine if any consumer routing rule exists for Qp(t)(s) data type. 9. Rescind Data Type Qp(t)(n) as Produced. 10. Determine if any consumer routing rule exists for Qp(t)(n) data type. The pattern would repeat itself for any registered consumer of these data types. + +Figure A.2-5: Second Illustrative Example - rApp Q Rescinds Produced Data + +# --- Annex ZZZ: O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN + +Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of O-RAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance's sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. + +Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or third party beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full force and effect. \ No newline at end of file diff --git a/marked/WG2/O-RAN.WG2.R1TP-v04.02/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG2/O-RAN.WG2.R1TP-v04.02/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.R1TP-v04.02/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG2/O-RAN.WG2.R1TP-v04.02/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG2/O-RAN.WG2.R1TP-v04.02/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.R1TP-v04.02/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG2/O-RAN.WG2.R1TP-v04.02/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG2/O-RAN.WG2.R1TP-v04.02/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.R1TP-v04.02/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG2/O-RAN.WG2.R1TP-v04.02/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG2/O-RAN.WG2.R1TP-v04.02/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG2/O-RAN.WG2.R1TP-v04.02/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG2/O-RAN.WG2.R1TP-v04.02/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG2/O-RAN.WG2.R1TP-v04.02/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG2/O-RAN.WG2.R1TP-v04.02/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG2/O-RAN.WG2.R1TP-v04.02/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG2/O-RAN.WG2.R1TP-v04.02/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.R1TP-v04.02/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG2/O-RAN.WG2.R1TP-v04.02/raw.md b/marked/WG2/O-RAN.WG2.R1TP-v04.02/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..b90c785030cb2da2e5cf4ca250644d824bff5c65 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.R1TP-v04.02/raw.md @@ -0,0 +1,254 @@ + + +# Transport Protocols for R1 Services + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|---------------------------------------------------------|---| +| Foreword ..... | 3 | +| Modal verbs terminology ..... | 3 | +| 1. Scope..... | 4 | +| 2. References..... | 4 | +| 2.1 Normative references ..... | 4 | +| 2.2 Informative references..... | 4 | +| 3. Definition of terms, symbols and abbreviations ..... | 5 | +| 3.1 Terms..... | 5 | +| 3.2 Symbols..... | 5 | +| 3.3 Abbreviations ..... | 5 | +| 4. Transport protocols for R1 Services ..... | 6 | +| 4.1 General ..... | 6 | +| 5. REST based protocol stack ..... | 6 | +| 5.1 General ..... | 6 | +| 5.2 Network layer..... | 6 | +| 5.3 Transport layer ..... | 6 | +| 5.4 Security..... | 6 | +| 5.5 Application..... | 7 | +| 5.6 Data interchange..... | 7 | +| 6. Kafka based protocol stack ..... | 8 | +| 6.1 General ..... | 8 | +| 6.2 Network layer..... | 8 | +| 6.3 Transport layer ..... | 8 | +| 6.4 Security..... | 8 | +| 6.5 Application..... | 8 | +| 6.6 Data interchange..... | 9 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG2 of the O-RAN Alliance. It is part of a TS-family covering the O-RAN WG2: R1 interface specifications. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1. Scope + +The present document specifies the transport protocols for R1 services. + +--- + +# 2. References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] IETF RFC 791: "Internet Protocol" ("IPV4"). +- [2] IETF RFC 793: "Transmission Control Protocol"("TCP"). +- [3] Void. +- [4] Void. +- [5] Void. +- [6] Void. +- [7] Void. +- [8] IETF RFC 8259: "The JavaScript Object Notation (JSON) Data Interchange Format" ("JSON"). +- [9] IETF RFC 8200: "Internet Protocol, Version 6 (IPv6) Specification" ("IPV6"). +- [10] IETF RFC 8446: "The Transport Layer Security Protocol Version 1.3" ("TLS"). +- [11] O-RAN TS: "R1 interface: General Aspects and Principles" ("R1GAP"). +- [12] O-RAN TS: "Security Requirements and Controls Specifications" ("SRS"). +- [13] O-RAN TS: "Security Protocols Specifications"("SPS"). +- [14] IETF RFC 6749: "The OAuth 2.0 Authorization Framework" ("OAuth2.0"). +- [15] IETF RFC 7519: "JSON Web Token" ("JWT"). +- [16] IETF RFC 9110: "HTTP Semantics" ("HTTP"). +- [17] IETF RFC 9112: "HTTP/1.1" ("HTTP/1.1"). +- [18] IETF RFC 9113: "HTTP/2" ("HTTP/2"). +- [19] O-RAN TS: "Application Protocols for R1 Services"("R1AP"). +- [20] Kafka Protocol Guide: . + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +[i.1] Kafka Documentation: + +# --- 3. Definition of terms, symbols and abbreviations + +## 3.1 Terms + +Void + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in "O-RAN TS R1GAP"[11] and the following apply: + +| | | +|-------|-------------------------------| +| HTTP: | Hypertext Transfer Protocol | +| JSON: | JavaScript Object Notation | +| TCP: | Transmission Control Protocol | +| TLS: | Transport Layer Security | +| JWT: | JSON Web Tokens | + +# 4. Transport protocols for R1 Services + +## 4.1 General + +The R1 interface is defined between the rApps and the Non-RT RIC framework, as defined in R1GAP [11]. + +# 5. REST based protocol stack + +## 5.1 General + +The layers of the protocol stack for the R1 interface are described in the following chapters: + +- TCP [2] provides the communication service at the transport layer, +- TLS [10] is used as specified in clause 4.2 of SPS [13] to provide secure HTTP [17] [18] connections, +- HTTP [16] [17] [18] is used as application-level protocol, +- The data interchange layer constitutes the transport of documents in the JSON format [8]. + +Figure 5.1-1 illustrates the REST based protocol stack for the R1 interface. + +| | | +|------------------|------------------------| +| Data Interchange | JSON | +| Application | HTTP | +| Security | TLS | +| Transport | TCP | +| Network | IP | +| Data Link | Data link layer | +| Physical | Physical layer | + +**Figure 5.1-1: REST Based Protocol Stack for the R1 Interface** + +## 5.2 Network layer + +As network layer at least one of IPv6 [9] or IPv4 [1] shall be supported. + +## 5.3 Transport layer + +TCP [2] shall be supported as transport protocol. + +NOTE: When using TCP as the transport protocol, an HTTP connection is mapped to a TCP connection. + +## 5.4 Security + +The specification of security controls on the R1 interface in clause 5.2.6.2 of SRS [12] shall be followed. + +These security controls refer to the detailed specification of the support and use of TLS v1.2 and TLS v1.3 (IETF RFC 8446 [10]), and OAuth2.0 [14] with JSON Web Tokens (JWT) (IETF RFC 7519 [15]) in the O-RAN TS SPS [13]. + +## 5.5 Application + +As application layer, HTTP/1.1 [17] shall be supported, and HTTP/2 [18] should be supported. The HTTP semantics as defined in IETF RFC 9110 [16] shall be supported. + +HTTP over TLS (as defined in IETF RFC 9112 for HTTP/1.1 [17] and in IETF RFC 9113 [18] for HTTP/2) shall be supported. + +HTTP details such as use of standard headers, custom headers, error codes, methods, URIs etc. will be specified in Application Protocols for R1 Services. + +The default TCP port numbers should be used for HTTP operation. + +## 5.6 Data interchange + +As a data interchange format, JSON [8] shall be supported. + +# 6. Kafka based protocol stack + +## 6.1 General + +The Kafka based protocol stack for the R1 interface includes the following layers: + +- TCP [2] provides the communication service at the transport layer, +- TLS [10] is used to provide secure connections at the security layer, + +NOTE: Specific security requirement references for Kafka based protocol stack are not specified in the present document. + +- The Kafka Protocol Guide [20] is used at the application layer, +- The data interchange layer constitutes the serialization format in which data are represented. + +Figure 6.1-1 illustrates the Kafka based protocol stack for the R1 interface. + +| Data Interchange | Serialization format | +|------------------|----------------------| +| Application | Kafka | +| Security | TLS | +| Transport | TCP | +| Network | IP | +| Data Link | Data link layer | +| Physical | Physical layer | + +**Figure 6.1-1: Kafka Based Protocol Stack for the R1 interface** + +## 6.2 Network layer + +As network layer at least one of IPv6 [9] or Ipv4 [1] shall be supported. + +## 6.3 Transport layer + +TCP [2] shall be supported as defined in Kafka Protocol Guide [20]. + +## 6.4 Security + +NOTE: Specific security requirement references for Kafka based protocol stack are not specified in the present document. + +## 6.5 Application + +As application layer, Kafka Protocol Guide [20] version 3.0 or higher shall be supported. The Kafka semantics are defined in the Kafka Documentation [i.1]. + +R1 service procedures as defined in R1GAP [11] are mapped to the Kafka protocol in R1AP [19] . + +## 6.6 Data interchange + +The Kafka based protocol stack for the R1 interface is agnostic to the data serialization format. + +# --- Annex A (informative): Change history + +| Date | Revision | Description | +|------------|----------|-----------------------------------------------------------------------------------------------| +| 2024-03-18 | 04.02 | Update the specification by removing the TLS1.2 reference across the specifications | +| 2023-11-20 | 04.01 | Updated the version of the Kafka in the Application layer and published as final version 4.01 | +| 2023-07-29 | 04.00 | Published as Final version 4.0 | +| 2023-03-24 | 03.00 | Published as Final version 3.0 | +| 2022-07-28 | 02.00 | Published as Final version 2.0 | +| 2022-03-31 | 01.00 | Published as Final version 1.0 | \ No newline at end of file diff --git a/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/86a771f11fbc580d8fda7a877acd1c69_img.jpg b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/86a771f11fbc580d8fda7a877acd1c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82827af191c934857f3a5a97842fa19fb4aa5978 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/86a771f11fbc580d8fda7a877acd1c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54f690c723a011f67b244eeda5cca1f67e7a7784e122d72a637cea1ca968c8f4 +size 4531 diff --git a/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/a7c4d732d1bee610783e72593835d0d1_img.jpg b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/a7c4d732d1bee610783e72593835d0d1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..11535b59bf158793fb008839377884fc42555f9f --- /dev/null +++ b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/a7c4d732d1bee610783e72593835d0d1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cd1cbed622fb448674fab54aeb04d92db4c82b5e4f211a7047d4d43a8018fbe +size 10914 diff --git a/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f9786619d9266ddf6962b7631fad8834bd583a3 --- /dev/null +++ b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:17a48c732b82959a70a4744afdf56099b05c77a70dfcfaa935549c6ab678bec2 +size 4509 diff --git a/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/raw.md b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..206b83a90e50fa334a909522bb19805c138d1c4b --- /dev/null +++ b/marked/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04/raw.md @@ -0,0 +1,218 @@ + + +# --- A1 interface: Transport Protocol + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|--------------------------------------------------------|----------| +| Foreword..... | 3 | +| Modal verbs terminology ..... | 3 | +| 1 Scope..... | 4 | +| 2 References ..... | 4 | +| 2.1 Normative references ..... | 4 | +| 2.2 Informative references ..... | 5 | +| 3 Definition of terms, symbols and abbreviations ..... | 5 | +| 3.1 Terms ..... | 5 | +| 3.2 Symbols..... | 5 | +| 3.3 Abbreviations ..... | 5 | +| 4 A1 interface protocol stack ..... | 5 | +| 4.1 General..... | 5 | +| 4.2 Reference model ..... | 5 | +| 4.3 Functions and protocol stack ..... | 6 | +| 5 Network layer..... | 6 | +| 6 Transport layer ..... | 7 | +| 7 Security ..... | 7 | +| 8 Application..... | 7 | +| 9 Data interchange..... | 7 | +| Annex (informative): Change History ..... | 8 | + +# --- Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance Working Group 2. It is part of a TS-family covering the A1 interface as identified below: + +- "A1 interface: General Aspects and Principles"; +- "A1 interface: Use Cases and Requirements"; +- "A1 interface: Transport Protocol"; +- "A1 interface: Application Protocol"; +- "A1 interface: Type Definitions"; and +- "A1 interface: Test Specification". + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the transport protocol stack for the A1 interface. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN TS: "A1 interface: General Aspects and Principles" ("A1GAP"). +- [2] O-RAN TS: "A1 interface: Application Protocol" ("A1AP"). +- [3] O-RAN TS: "A1 interface: Type Definitions" ("A1TD"). +- [4] IETF RFC 793: "Transmission Control Protocol". +- [5] Void. +- [6] IETF RFC 8446: "The Transport Layer Security (TLS) Protocol Version 1.3". +- [7] Void. +- [8] Void. +- [9] Void. +- [10] Void. +- [11] IETF RFC 8259: "The JavaScript Object Notation (JSON) Data Interchange Format". +- [12] IETF RFC 8200: "Internet Protocol, Version 6 (IPv6) Specification". +- [13] IETF RFC 791: "Internet Protocol". +- [14] Void. +- [15] Void. +- [16] O-RAN TS: "O-RAN Security Requirements and Controls Specifications" ("SRS"). +- [17] O-RAN TS: "O-RAN Security Protocols Specifications" ("SPS"). +- [18] IETF RFC 9110: "HTTP Semantics". +- [19] IETF RFC 9112: "HTTP/1.1". +- [20] IETF RFC 9113: "HTTP/2". + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +Not applicable. + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in A1GAP [1], clause 3.1, apply. + +## 3.2 Symbols + +Void. + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in A1GAP [1], clause 3.3, and the following apply: + +| | | +|------|---------------------------------| +| IETF | Internet Engineering Task Force | +| JWT | JSON Web Tokens | +| RFC | Request For Comments | + +# --- 4 A1 interface protocol stack + +## 4.1 General + +The architecture for the A1 interface is specified in A1GAP [1], clause 4.1. The protocol stack for the A1 interface supports application protocol and data models as specified in A1AP [2] and A1TD [3]. + +## 4.2 Reference model + +The A1 interface is defined between the Non-RT RIC and the Near-RT RIC functions. The A1 architecture and principles are described in A1GAP [1], clause 4. Figure 4.2-1 illustrates the reference model for the A1 interface. + +![Figure 4.2-1: A1 interface reference model. A diagram showing two rectangular boxes, 'Non-RT RIC' at the top and 'Near-RT RIC' at the bottom, connected by a vertical double-headed arrow. The arrow is labeled 'A1 interface'.](a7c4d732d1bee610783e72593835d0d1_img.jpg) + +``` + +graph TD + Non-RT-RTIC[Non-RT RIC] <--> |A1 interface| Near-RT-RTIC[Near-RT RIC] + +``` + +Figure 4.2-1: A1 interface reference model. A diagram showing two rectangular boxes, 'Non-RT RIC' at the top and 'Near-RT RIC' at the bottom, connected by a vertical double-headed arrow. The arrow is labeled 'A1 interface'. + +**Figure 4.2-1: A1 interface reference model** + +## 4.3 Functions and protocol stack + +The following layers of the protocol stack for the A1 interface are described in the following clauses: + +- TCP as specified in IETF RFC 793 [4] provides the communication service at the transport layer; +- TLS as specified in IETF RFC 8446 [6] is used to provide secure HTTP connections; +- HTTP as specified in IETF RFC 9110 [18], IETF RFC 9112 [19] and IETF RFC 9113 [20] is used as application-level protocol; +- The data interchange layer constitutes the transport of documents in the JSON format as specified in IETF RFC 8259 [11]. + +Figure 4.3-1 illustrates the protocol stack of the A1 interface. + +| | | +|------------------|-----------------| +| Data Interchange | JSON | +| Application | HTTP | +| Security | TLS | +| Transport | TCP | +| Network | IP | +| Data link | Data link layer | +| Physical | Physical layer | + +**Figure 4.3-1: A1 protocol stack** + +# 5 Network layer + +A1 may be transported over IPv6 as specified in IETF RFC 8200 [12] and/or IPv4 as specified in IETF RFC 791 [13]. + +# --- 6 Transport layer + +TCP as specified in IETF RFC 793 [4] shall be used as transport protocol. An HTTP connection is mapped to a TCP connection. + +Both Non-RT RIC and Near-RT RIC can act as HTTP client and HTTP server. As a result, Non-RT RIC and Near-RT RIC can establish a TCP connection for each direction. + +# --- 7 Security + +TLS, mTLS, and OAuth2.0 shall be supported as specified in SRS [16], clause 5.2.1. + +mTLS and OAuth 2.0 with JWT shall be supported as specified in SPS [17], clause 4.7. + +# --- 8 Application + +As application layer, HTTP/1.1 as specified in IETF RFC 9112 [19] shall be supported, and HTTP/2 as specified in IETF RFC 9113 [20] should be supported. + +HTTP over TLS as specified in IETF RFC 9110 [18] and IETF RFC 9112 [19] shall be supported. If HTTP/2 is supported, HTTP/2 over TLS as specified in IETF RFC 9113 [20] shall be supported. + +HTTP details such as standard headers, custom headers, error codes, methods, URIs etc are specified in A1AP [2]. + +The default TCP port numbers should be used for HTTP operation. + +# --- 9 Data interchange + +As a data interchange format, JSON as specified in IETF RFC 8259 [11] shall be supported. The objects transported in HTTP messages, and the data types in JSON format, are specified in A1TD [3]. + +# --- Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|----------------------------------------------------------------------------------------------------------| +| 2019.09.30 | 01.00 | First version | +| 2021.03.13 | 01.01 | Editorial corrections to apply latest template and update references. Clarification of HTTP port number. | +| 2022.07.30 | 02.00 | Adapting to ODR template and referring to O-RAN security specifications for mTLS and OAuth2.0 | +| 2022.11.17 | 02.01 | Aligning to O-RAN drafting rules | +| 2023.07.31 | 03.00 | Updating obsolete references and applying latest template | +| 2023.11.30 | 03.01 | ETSI PAS related editorial enhancements of references in clause 7 | +| 2024.03.31 | 03.02 | Editorial enhancement of references | +| 2024.07.31 | 03.03 | Updated specification designator to R004 | +| 2024.11.30 | 03.04 | Editorial enhancement of references | \ No newline at end of file diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/17398cfc35dde22fa5a80caabe669739_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/17398cfc35dde22fa5a80caabe669739_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ae115f85c71c7c4dd5ac246f8d02e9dc29c8af6 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/17398cfc35dde22fa5a80caabe669739_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c5775240b9ed1a2100a9c61aca08d03763ec191986acc2c52895232c0e85e48b +size 4429 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/551e35d264492786d0d610557ccc1b55_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/551e35d264492786d0d610557ccc1b55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eca96f14eff173ab5ead5b4ef80ff5827e92c33d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/551e35d264492786d0d610557ccc1b55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8bb0af2dd788e055159db7a05c0b9285e7d655c861421ac8dc37e4b94c3b343 +size 4454 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/7a7d70b11f2431b906436beee951553b_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/7a7d70b11f2431b906436beee951553b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..15dfbde67b12223eb9616299f1c147ea7be8870f --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/7a7d70b11f2431b906436beee951553b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e5cb00bafd8271aaa6cab005612571be1345775000f06d3abb243f6718d31597 +size 48663 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/866306db28209e9e635ceb2b3746d1d3_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/866306db28209e9e635ceb2b3746d1d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8eabd8acd78f92e69bfb78524be63e87dd6abed5 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/866306db28209e9e635ceb2b3746d1d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:25865055d86dd3193f213709593c9f45a00f62b4da14123775d728e6d458850c +size 89013 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/8df97f43bb4b250b1d647bd375155e5a_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/8df97f43bb4b250b1d647bd375155e5a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..99d51db6a2c18dcbe6bcc1f561696a4e371a21f0 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/8df97f43bb4b250b1d647bd375155e5a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ecb2d471360b4d468ad5d5c8340c5d4addd77780d4445c6363b69978de3c22e +size 4544 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/99e3ecf377ea9aee9f26bae1fab933f0_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/99e3ecf377ea9aee9f26bae1fab933f0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a02a327534eb94d50cab0f3bb135a904536b18fb --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/99e3ecf377ea9aee9f26bae1fab933f0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c8ea023e26c51a827e318e5fb7ae277855986c44401f1e9ecc6f1c91a63fbc4b +size 4601 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..08a9c509da7e591b85ce9c11c7659f729776badc --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e51e29a8c647908fe9f48f56b660f7378772dafa9202a271bcb2032f560fafe1 +size 4531 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/bb44133bea631663a95f3dc378735c28_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/bb44133bea631663a95f3dc378735c28_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..65213395f2cf861c18ab4ad518eae37a9909ddd0 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/bb44133bea631663a95f3dc378735c28_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bffd0b8fbc09ace7850dabd80896bf1ced586857838df9d3cebd69f84c2c141a +size 50159 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/raw.md b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..742325f847eba24bbded72386b5c5b951808d2a8 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.E2TS-R003-v02.00/raw.md @@ -0,0 +1,4238 @@ + + +# --- **O-RAN Work Group 3 E2 Interface Test Specification** + +Copyright © 2023 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +1 +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 +16 +17 +18 +19 +20 +21 +22 +23 +24 +25 +26 +27 +28 + +# Contents + +| | | | | +|----|------------------------------------------------------------------------------------------------------|--|----| +| 1 | | | | +| 2 | Foreword ..... | | 6 | +| 3 | Modal verbs terminology ..... | | 6 | +| 4 | 1 Scope..... | | 6 | +| 5 | 2 References..... | | 6 | +| 6 | 2.1 Normative references ..... | | 6 | +| 7 | 2.2 Informative references..... | | 7 | +| 8 | 3 Definitions of terms, symbols and and Abbreviations..... | | 7 | +| 9 | 3.1 Terms..... | | 7 | +| 10 | 3.2 Symbols..... | | 7 | +| 11 | 3.3 Abbreviations ..... | | 7 | +| 12 | 4 Test methodology..... | | 9 | +| 13 | 4.1 General ..... | | 9 | +| 14 | 4.2 Conformance testing Near-RT RIC..... | | 9 | +| 15 | 4.2.1 General ..... | | 9 | +| 16 | 4.2.2 Test configuration..... | | 9 | +| 17 | 4.2.2.1 Device Under Test (Near-RT RIC)..... | | 10 | +| 18 | 4.2.2.2 Testing Tools ..... | | 10 | +| 19 | 4.3 Conformance testing E2 Nodes..... | | 10 | +| 20 | 4.3.1 General ..... | | 10 | +| 21 | 4.3.2 Test configuration..... | | 10 | +| 22 | 4.3.2.1 Device Under Test (E2 Node) ..... | | 11 | +| 23 | 4.3.2.2 Testing Tools ..... | | 12 | +| 24 | 4.4 Interoperability Testing between Near-RT RIC and E2 Node..... | | 12 | +| 25 | 4.4.1 General ..... | | 12 | +| 26 | 4.4.2 Test configuration..... | | 12 | +| 27 | 4.4.2.1 System Under Test (Near-RT RIC and E2 Node) ..... | | 13 | +| 28 | 4.4.2.2 Testing Tools ..... | | 14 | +| 29 | 5 Test Cases for Near-RT RIC ..... | | 14 | +| 30 | 5.1 General ..... | | 14 | +| 31 | 5.2 Conformance Test Cases..... | | 14 | +| 32 | 5.2.1 E2AP Global Procedures ..... | | 14 | +| 33 | 5.2.1.1 Test Cases for E2 Setup ..... | | 14 | +| 34 | 5.2.1.1.1 E2 Setup (positive case) ..... | | 14 | +| 35 | 5.2.1.2 Test Cases for RESET procedure ..... | | 15 | +| 36 | 5.2.1.2.1 Reset procedure (initiated by E2 Node) (positive case)..... | | 15 | +| 37 | 5.2.1.2.2 Reset procedure (initiated by Near-RT RIC) (positive case)..... | | 16 | +| 38 | 5.2.1.3 Test Cases for Error Indication ..... | | 17 | +| 39 | 5.2.1.3.1 Error Indication procedure ..... | | 17 | +| 40 | 5.2.1.4 Test Cases for RIC Service Update procedure ..... | | 19 | +| 41 | 5.2.1.4.1 RIC Service Update procedure with RAN Function modified (positive case) ..... | | 19 | +| 42 | 5.2.1.4.2 RIC Service Update procedure with RAN Function deleted (positive case) ..... | | 20 | +| 43 | 5.2.1.4.3 RIC Service Update procedure with RAN Function added (positive case) ..... | | 21 | +| 44 | 5.2.1.5 Test Cases for E2 Node Configuration Update procedure ..... | | 22 | +| 45 | 5.2.1.5.1 E2 Node Configuration Update procedure with E2 Node configuration added (positive) ..... | | 22 | +| 46 | 5.2.1.5.2 E2 Node Configuration Update procedure with E2 Node configuration updated (positive) ..... | | 24 | +| 47 | 5.2.1.5.3 E2 Node Configuration Update procedure with E2 Node configuration removed (positive)..... | | 25 | +| 48 | 5.2.1.6 Test Cases for E2 Connection Update procedure ..... | | 27 | +| 49 | 5.2.1.6.1 E2 Connection Update procedure with TNL Association added (positive case)..... | | 27 | +| 50 | 5.2.1.7 Test Cases for E2 Removal procedure..... | | 28 | +| 51 | 5.2.1.7.1 E2 Removal procedure initiated by E2 Node (positive case)..... | | 28 | +| 52 | 5.2.1.7.2 E2 Removal procedure initiated by Near-RT RIC (positive case)..... | | 29 | +| 53 | 5.2.2 E2AP Functional Procedures..... | | 30 | +| 54 | 5.2.2.1 Test Cases for RIC Subscription procedure..... | | 30 | +| 55 | 5.2.2.1.1 RIC Subscription procedure for single RIC action (positive) ..... | | 30 | + +| | | | | +|----|-----------|-----------------------------------------------------------------------------------------------------------------------------------|----| +| 1 | 5.2.2.2 | Test Cases for RIC Subscription Delete ..... | 32 | +| 2 | 5.2.2.2.1 | RIC Subscription Delete procedure (positive) ..... | 32 | +| 3 | 5.2.2.3 | Test Cases for RIC Subscription Delete Required procedure..... | 34 | +| 4 | 5.2.2.3.1 | RIC Subscription Delete Required procedure (positive)..... | 34 | +| 5 | 5.2.2.4 | Test Cases for RIC Indication procedure..... | 35 | +| 6 | 5.2.2.4.1 | RIC Indication procedure for REPORT Service (positive)..... | 35 | +| 7 | 5.2.2.5 | Test Cases for RIC Control procedure..... | 36 | +| 8 | 5.2.2.5.1 | RIC Control procedure for CONTROL Service (positive) ..... | 36 | +| 9 | 5.2.3 | E2AP Functional Procedures for E2SM-KPM ..... | 38 | +| 10 | 5.2.3.1 | Test Cases for RIC Subscription E2SM-KPM ..... | 38 | +| 11 | 5.2.3.1.1 | RIC Subscription procedure with REPORT Service Style 1, Single Action Format Type 1
    (positive)..... | 38 | +| 12 | 5.2.3.1.2 | RIC Subscription procedure with REPORT Service Style 2, Single Action Format Type 2
    (positive)..... | 40 | +| 13 | 5.2.3.1.3 | RIC Subscription procedure with REPORT Service Style 1, Single Action Format Type 1
    (negative)..... | 41 | +| 14 | 5.2.3.1.4 | RIC Subscription procedure with REPORT Service Style 2, Single Action Format Type 2
    (negative)..... | 43 | +| 15 | 5.2.3.1.5 | RIC Subscription procedure with REPORT Service Style 1, Single Action Format Type 1 for
    multiple measurements (positive) ..... | 45 | +| 16 | 5.2.3.1.6 | RIC Subscription procedure with REPORT Service Style 2, Single Action Format Type 2 for
    multiple measurements (positive) ..... | 48 | +| 17 | 5.2.3.1.7 | RIC Indication procedure for REPORT Service style 1 for multiple measurements (positive) ..... | 50 | +| 18 | 5.2.3.1.8 | RIC Indication procedure for REPORT Service style 2 for multiple measurements (positive) ..... | 52 | +| 19 | 5.2.3.2 | Test Cases for RIC Indication E2SM-KPM ..... | 54 | +| 20 | 5.2.3.2.1 | RIC Indication procedure with REPORT Service style 1 (positive)..... | 54 | +| 21 | 5.2.3.2.2 | RIC Indication procedure for REPORT Service style 2 (positive) ..... | 55 | +| 22 | 5.2.4 | E2AP Functional Procedures for E2SM-RC ..... | 57 | +| 23 | 5.2.5 | E2AP Functional Procedures for E2SM-NI ..... | 57 | +| 24 | 5.2.5.1 | Test Cases for RIC Subscription E2SM-NI..... | 57 | +| 25 | 5.2.5.1.1 | RIC Subscription for RIC REPORT Style 1, Single Action, RIC Event Trigger 1 (positive
    case)..... | 57 | +| 26 | 6 | Test Cases for E2 Nodes ..... | 59 | +| 27 | 6.1 | General ..... | 59 | +| 28 | 6.2 | Conformance Test Cases..... | 59 | +| 29 | 6.2.1 | E2AP Global Procedures ..... | 59 | +| 30 | 6.2.1.1 | Test Cases for E2 Setup procedure ..... | 59 | +| 31 | 6.2.1.1.1 | E2 Setup ..... | 59 | +| 32 | 6.2.1.2 | Test Cases for RESET procedure ..... | 60 | +| 33 | 6.2.1.2.1 | Reset procedure (initiated by Near-RT RIC) (positive case)..... | 60 | +| 34 | 6.2.1.2.2 | Reset procedure (initiated by E2 Node) (positive case)..... | 61 | +| 35 | 6.2.1.3 | Test Cases for Error Indication..... | 62 | +| 36 | 6.2.1.3.1 | Error Indication procedure (Transfer Syntax Error) ..... | 62 | +| 37 | 6.2.1.4 | Test Cases for RIC Service Update procedure ..... | 64 | +| 38 | 6.2.1.4.1 | RIC Service Update procedure with empty RIC SERVICE QUERY message (positive case)..... | 64 | +| 39 | 6.2.1.4.2 | RIC Service Update procedure with RIC SERVICE QUERY message provided list of
    Accepted RAN functions (positive case) ..... | 65 | +| 40 | 6.2.1.5 | Test Cases for E2 Node Configuration Update procedure ..... | 67 | +| 41 | 6.2.1.5.1 | E2 Node Configuration Update procedure after a Near-RT RIC initiated addition of a new
    TNL association (positive case) ..... | 67 | +| 42 | 6.2.1.5.2 | E2 Node Configuration Update procedure for E2 Node initiated TNL association removal
    (positive case)..... | 68 | +| 43 | 6.2.1.6 | Test Cases for E2 Connection Update procedure ..... | 70 | +| 44 | 6.2.1.6.1 | E2 Connection Update procedure for adding additional TNL Association (positive case) ..... | 70 | +| 45 | 6.2.1.7 | Test Cases for E2 Removal Procedure ..... | 71 | +| 46 | 6.2.1.7.1 | E2 Removal procedure initiated by E2 Node (positive case)..... | 71 | +| 47 | 6.2.1.7.2 | E2 Removal procedure initiated by Near-RT RIC (positive case)..... | 72 | +| 48 | 6.2.2 | E2AP Functional Procedures..... | 74 | +| 49 | 6.2.2.1 | Test Cases for RIC Subscription procedure..... | 74 | +| 50 | 6.2.2.1.1 | RIC Subscription procedure for single RIC action (positive) ..... | 74 | + +| | | | | +|----|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| 1 | 6.2.2.2 | Test Cases for RIC Subscription Delete procedure ..... | 76 | +| 2 | 6.2.2.2.1 | RIC Subscription Delete procedure (positive) ..... | 76 | +| 3 | 6.2.2.2.2 | RIC Subscription Delete Request procedure (Negative)-RIC Request ID unknown. .... | 77 | +| 4 | 6.2.2.2.3 | RIC Subscription Delete procedure (Negative)-RAN Function ID invalid. .... | 79 | +| 5 | 6.2.2.3 | Test Cases for RIC Subscription Delete Required procedure..... | 80 | +| 6 | 6.2.2.3.1 | RIC Subscription Delete Required procedure (positive)..... | 80 | +| 7 | 6.2.2.4 | Test Cases for RIC Indication procedure..... | 81 | +| 8 | 6.2.2.4.1 | RIC Indication procedure for REPORT Service (positive)..... | 81 | +| 9 | 6.2.2.5 | Test Cases for RIC Control procedure..... | 83 | +| 10 | 6.2.2.5.1 | RIC Control procedure for CONTROL Service (positive) ..... | 83 | +| 11 | 6.2.3 | E2AP Functional Procedures for E2SM-KPM..... | 85 | +| 12 | 6.2.4 | E2AP Functional Procedures for E2SM-RC ..... | 85 | +| 13 | 6.2.5 | E2AP Functional Procedures for E2SM-NI ..... | 85 | +| 14 | 7 | Test Cases for Interoperability between Near-RT RIC and E2 Node..... | 85 | +| 15 | 7.1 | General ..... | 85 | +| 16 | 7.1.1 | Protocol Analyzer and TAP Interface ..... | 85 | +| 17 | 7.2 | Interoperability Test Cases..... | 85 | +| 18 | 7.2.1 | Test Cases for E2AP Global Procedures ..... | 85 | +| 19 | 7.2.1.1 | Near-RT RIC Support procedures ..... | 85 | +| 20 | 7.2.1.1.1 | Test Purpose ..... | 85 | +| 21 | 7.2.1.1.2 | Test Entrance Criteria..... | 85 | +| 22 | 7.2.1.1.3 | Test Methodology ..... | 86 | +| 23 | 7.2.2 | Test Cases for E2AP Functional Procedures for E2SM-KPM..... | 88 | +| 24 | 7.2.2.1 | Tests cases for RIC REPORT Service Styles procedures E2SM-KPM ..... | 88 | +| 25 | 7.2.2.1.1 | RIC Subscription and RIC Indication procedures with REPORT Service Style 1, Single
    Action Format Type 1, Indication Message Format Type 1 ..... | 88 | +| 27 | 7.2.2.1.2 | RIC Subscription and RIC Indication procedures with REPORT Service Style 2, Single
    Action Format Type 2, Indication Message Format Type 1 ..... | 90 | +| 29 | 7.2.2.1.3 | RIC Subscription and RIC Indication procedures with REPORT Service Style 3, Single
    Action Format Type 3, Indication Message Format Type 2 ..... | 92 | +| 31 | 7.2.2.2 | Tests cases for RIC INSERT Service Styles procedures E2SM-KPM..... | 95 | +| 32 | 7.2.2.3 | Tests cases for RIC CONTROL Service Styles procedures E2SM-KPM..... | 95 | +| 33 | 7.2.2.4 | Tests cases for RIC POLICY Service Styles procedures E2SM-KPM ..... | 95 | +| 34 | 7.2.2.5 | Tests cases for RIC Subscription Delete procedures E2SM-KPM..... | 95 | +| 35 | 7.2.2.5.1 | RIC Subscription Delete procedure with RIC Event Trigger Style 1 ..... | 95 | +| 36 | 7.2.3 | Test Cases for E2AP Functional Procedures for E2SM-RC ..... | 97 | +| 37 | 7.2.4 | Test Cases for E2AP Functional Procedures for E2SM-NI ..... | 97 | +| 38 | | Revision history..... | 98 | +| 39 | | History ..... | 101 | +| 40 | | | | +| 41 | | | | +| 42 | | | | + +# Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +# Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document specifies test configurations and test cases for E2 interface testing including conformance testing of the Near- RT RIC over E2 interface, conformance testing of the E2 Nodes over E2 interface and interoperability testing with Near-RT RIC and E2 Nodes over E2 interface. + +# 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN.WG3.E2GAP-v02.00: "O-RAN Working Group 3 Near-Real-time RAN Intelligent Controller, E2 General Aspects and Principles". +- [2] O-RAN.WG3.E2AP-v02.00: "O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Application Protocol (E2AP)". +- [3] O-RAN.WG3.E2SM-v02.00: "O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Service Model (E2SM)". + +- [4] O-RAN.WG3.E2SM-NI-v01.00: “O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Service Model, Network Interface (E2SM-NI)”. +- [5] O-RAN.WG3.E2SM-KPM-v02.00: “O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Service Model, KPI Monitor (E2SM-KPM)”. +- [6] O-RAN.WG3.E2SM-RC-v01.00: “O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Service Model, RAN Control (E2SM-RC)”. +- [7] O-RAN.WG3.RICARCH-v01.01: “O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, Near-RT RIC Architecture”. +- [8] O-RAN.WG1.O-RAN Architecture Description: “O-RAN Architecture Description”. +- [9] O-RAN.WG1.OAM Architecture: “O-RAN Operations and Maintenance Architecture”. +- [10] O-RAN.WG3.E2SM-CCC-v01.00: “O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Service Model, Cell Configuration and Control (E2SM-CCC)”. + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +[i.1] : "". + +# 3 Definitions of terms, symbols and and Abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +## 3.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply. + +| | | +|-------------|-------------------------------------------| +| DUT | Device Under Test | +| Near-RT RIC | near-real-time RAN Intelligent Controller | +| Non-RT RIC | non-real-time RAN Intelligent Controller: | +| O-CU | O-RAN Central Unit | +| O-CU-CP | O-RAN Central Unit – Control Plane | +| O-CU-UP | O-RAN Central Unit – User Plane | +| O-DU | O-RAN Distributed Unit | + +| | | | +|---|------|-------------------------| +| 1 | O-RU | O-RAN Radio Unit | +| 2 | TNL | Transport Network Layer | +| 3 | TNLA | TNL association | +| 4 | | | +| 5 | | | + +# 4 Test methodology + +## 4.1 General + +## 4.2 Conformance testing Near-RT RIC + +### 4.2.1 General + +### 4.2.2 Test configuration + +The test configuration for E2 conformance testing of Near-RT RIC is illustrated in Figure 4.2.2-1 which shows a test setup that employs an E2 Node simulator, O-RU simulator, and UE simulator as a simplification. A test set-up without use of simulations would require inclusion of an O-RU with associated M-Plane support and also a real UE or test UE. + +In as much as the conformance testing involves configuring the E2 Nodes and the Near-RT RIC, it shall be performed by means of the O1 interface. Configuration of the E2 Nodes and Near-RT RIC to operate in nominal state via the O1 interface and configuring for policy guidance and enrichment data to the Near-RT RIC via the A1 interface are outside the scope of this test specification. + +![Figure 4.2.2-1 Illustration of Near-RT RIC E2 conformance test setup. The diagram shows a hierarchical architecture. At the top, a dashed box contains 'SMO' and 'Non-RT RIC'. Below this, a solid box represents the 'Near-RT RIC'. The SMO connects to the Near-RT RIC via O1 and A1 interfaces. The Near-RT RIC connects to an 'E2 Node Simulator' via E2 interfaces. The E2 Node Simulator contains 'O-eNB', 'O-CU-CP', and 'O-CU-UP' components. The O-CU-CP and O-CU-UP are connected via E1. The O-CU-CP connects to 'O-DU' via F1-c, and the O-CU-UP connects to O-DU via F1-u. The O-DU connects to a 'UE Simulator' via a dashed line. To the right, a separate block shows 'DUT' (Device Under Test) and 'Test Equipment (actual or simulated)'.](7a7d70b11f2431b906436beee951553b_img.jpg) + +Figure 4.2.2-1 Illustration of Near-RT RIC E2 conformance test setup. The diagram shows a hierarchical architecture. At the top, a dashed box contains 'SMO' and 'Non-RT RIC'. Below this, a solid box represents the 'Near-RT RIC'. The SMO connects to the Near-RT RIC via O1 and A1 interfaces. The Near-RT RIC connects to an 'E2 Node Simulator' via E2 interfaces. The E2 Node Simulator contains 'O-eNB', 'O-CU-CP', and 'O-CU-UP' components. The O-CU-CP and O-CU-UP are connected via E1. The O-CU-CP connects to 'O-DU' via F1-c, and the O-CU-UP connects to O-DU via F1-u. The O-DU connects to a 'UE Simulator' via a dashed line. To the right, a separate block shows 'DUT' (Device Under Test) and 'Test Equipment (actual or simulated)'. + +**Figure 4.2.2-1 Illustration of Near-RT RIC E2 conformance test setup** + +Although the above test configuration diagrams illustrated Near-RT RIC, O-CU-CP, O-CU-UP, O-DU as separate entities, the E2 Node simulator may support a range of different RAN configurations similar to the list of cases described in “O-RAN.WG1.O-RAN-Architecture-Description” [8], Annex A.4. Examples include: + +- Standalone O-CU-CP connected to one or more standalone O-CU-UP and one or more standalone O-DU. Each logical node is considered as an E2 Node that presents an E2 interface to the Near-RT RIC. +- Combined O-CU-CP and O-CU-UP connected to one or more standalone O-DU. The combined O-CU-CP/O-CU-UP may present either a common E2 interface or individual E2 interfaces corresponding to the individual O-RAN components +- Combined O-CU-CP, O-CU-UP and O-DU. The combined node may present either a common E2 interface or individual E2 interfaces corresponding to the individual O-RAN components + +In all cases the different RAN components may initiate either independent E2 connections to the Near-RT RIC for each logical O-RAN component or may present a shared E2 interface and hence present the combined RAN components as a common E2 Node supporting services appropriate to more than one logical O-RAN components. The following RAN configurations where the Near-RT RIC are bundled with some or all of the O-RAN nodes as discussed in “O-RAN.WG1.O-RAN-Architecture-Description” [8], Annex A.4, are not addressed in this version of the specification. + +- Bundle the Near-RT RIC, O-CU-CP and O-CU-UP +- Bundle the Near-RT RIC, O-CU-CP, O-CU-UP, O-DU and O-RU + +#### 4.2.2.1 Device Under Test (Near-RT RIC) + +For enabling conformance testing, the Near-RT RIC has implemented the E2 interface, and the procedures specified in “O-RAN WG3: E2 Application Protocol” [2] that are required to perform testing of the applicable test cases. It may also support all or a subset of the E2 service models - E2SM-KPM, E2SM-NI and E2SM-RC as specified in “ORAN WG3: E2SM KPM” [5], “ORAN WG3: E2SM NI” [4] and “ORAN WG3: E2SM RC” [6] respectively. + +The DUT, Near-RT RIC, may comply to only a subset of E2 procedures and E2 service models. Therefore, only those testcases that relate to compliance claimed by a DUT are relevant. This is noted on a case-by-case basis in testcases defined in clause 5.2. + +#### 4.2.2.2 Testing Tools + +The E2 Node simulator simulates the E2 functionalities of the E2 Node side and have flexibility to generate, receive and validate messages for all the E2 global procedures and certain or all of the E2 service models. The test simulator logs all message content during the testing. + +The test simulator has all the capabilities needed to operate the E2 test cases, including: + +- Generate E2 Node initiated procedures. +- Receive Near-RT RIC initiated procedures. +- Generate responses for either successful or unsuccessful operations with appropriate cause value in case of failure. + +The test simulator should support all the RAN configurations discussed in clause 4.2.2, except those excluded in this version of the specification as described above. + +The E2 Node simulator may also logically simulate the UE functions from the Near-RT RIC point of view, enabling meaningful cell and UE specific E2 services to run. Only the UE functions sufficient to facilitate the E2 interface focused conformance testing are simulated. + +## 4.3 Conformance testing E2 Nodes + +### 4.3.1 General + +### 4.3.2 Test configuration + +The test configuration for E2 conformance testing of different types of E2 Nodes are illustrated in Figure 4.3.2-1. The test setup employs a Near-RT RIC simulator, O-RU simulator, Core simulator and UE simulator as a simplification. A test set-up without use of simulations would require inclusion of real equipment. Configuring E2 Nodes to bring it to nominal operating state via the O1 is outside the scope of this test specification. + +![Figure 4.3.2-1 Illustration of E2-Node conformance test setup. The diagram shows a Test Simulator (Near-RT RIC) connected to an SMO (Service Based Interface) and a Non-RT RIC. The Test Simulator is connected to O-eNB, O-CU-CP, and O-CU-UP via E2 interfaces. O-CU-CP and O-CU-UP are connected via E1. O-CU-CP and O-CU-UP are connected to O-DU via F1-c and F1-u respectively. O-DU is connected to a 4G/5G Core (simulated or real). The 4G/5G Core is connected to a DUT (Device Under Test) and Test Equipment (actual or simulated). The DUT and Test Equipment are connected to an RU and UE Simulator.](bb44133bea631663a95f3dc378735c28_img.jpg) + +Figure 4.3.2-1 Illustration of E2-Node conformance test setup. The diagram shows a Test Simulator (Near-RT RIC) connected to an SMO (Service Based Interface) and a Non-RT RIC. The Test Simulator is connected to O-eNB, O-CU-CP, and O-CU-UP via E2 interfaces. O-CU-CP and O-CU-UP are connected via E1. O-CU-CP and O-CU-UP are connected to O-DU via F1-c and F1-u respectively. O-DU is connected to a 4G/5G Core (simulated or real). The 4G/5G Core is connected to a DUT (Device Under Test) and Test Equipment (actual or simulated). The DUT and Test Equipment are connected to an RU and UE Simulator. + +**Figure 4.3.2-1 Illustration of E2-Node conformance test setup** + +Although the above test configuration diagrams illustrate O-CU-CP, O-CU-UP, O-DU as separate entities, the E2 Node may support a range of different RAN configurations similar to the list of cases described in “O-RAN.WG1.O-RAN-Architecture-Description” [8], Annex A.4. Examples include: + +- Standalone O-CU-CP connected to one or more standalone O-CU-UP and one or more standalone O-DU. Each logical node is considered as an E2 Node that presents an E2 interface to the Near-RT RIC. +- Combined O-CU-CP and O-CU-UP connected to one or more standalone O-DU. The combined O-CU-CP/O-CU-UP may present either a common E2 interface or individual E2 interfaces corresponding to the individual O-RAN components +- Combined O-CU-CP, O-CU-UP and O-DU. The combined node may present either a common E2 interface or individual E2 interfaces corresponding to the individual O-RAN components + +In all cases the different RAN components may initiate either independent E2 connections to the Near-RT RIC Simulator for each logical O-RAN component or may present a shared E2 interface and hence present the combined RAN components as a common E2 Node supporting services appropriate to more than one logical O-RAN component. + +The following RAN configurations where the Near-RT RIC is bundled with some or all of the O-RAN nodes as discussed in “O-RAN.WG1.O-RAN-Architecture-Description” [8], Annex A.4, are not addressed in this version of the specification. + +#### 4.3.2.1 Device Under Test (E2 Node) + +The DUT could be of any E2 Node of the following type + +- O-CU-CP, O-CU-UP or O-DU +- Combined O-CU-CP, O-CU-UP and O-DU +- Combined O-CU-CP and O-CU-UP +- O-DU +- O-eNB + +For conformance testing the E2 Node has E2AP interface and implements procedures specified in “O-RAN WG3: E2 Application Protocol” [2] that are required to perform testing of the applicable test cases. It may support all or a subset of the E2 service models - E2SM-KPM, E2SM-NI and E2SM-RC as specified in “ORAN WG3: E2SM KPM” [5], “ORAN WG3: E2SM NI” [4] and “ORAN WG3: E2SM RC” [6] respectively. + +The DUT (E2 Node ) may comply to only a subset of E2AP procedures and E2 service models. Therefore, only those testcases that relate to compliance claimed by a DUT are relevant. This is noted on a case-by-case basis in testcases defined in clause 6.2. + +#### 4.3.2.2 Testing Tools + +The Near-RT RIC simulator simulates the E2 functionalities of Near-RT RIC and has flexibility to generate, receive and validate messages for all the E2AP procedures and certain or all of the E2 service models. The test simulator logs all message contents during the testing. + +The test simulator has all the capabilities needed to operate the E2 test cases, including: + +- Generate Near-RT RIC initiated procedures. +- Receive E2 Node initiated procedures. +- Generate responses for either successful or unsuccessful operations with appropriate cause value in case of failure. + +The Test simulator (Near-RT RIC) should support all the RAN configurations discussed in clause 4.3.2, except those excluded in this version of the specification as described above. + +The test setup has the DUT (E2 Node) connect to other test equipment. These can be real or simulated UEs, RAN elements and Core (EPC or 5GC) to support scenarios appropriate for the E2 functionality being tested. An SMO with O1 interface is also included optionally if the E2 Node or any of real or simulated elements need configuration or operation to function. + +## 4.4 Interoperability Testing between Near-RT RIC and E2 Node + +### 4.4.1 General + +FFS + +### 4.4.2 Test configuration + +The test configuration for interoperability testing between Near-RT RIC and E2 Node(s) is illustrated in figure 4.4.2-1 which shows a test setup that employs a Non-RT RIC simulator, Core Simulator, O-RU simulator, and UE simulator as a simplification. A test set-up without use of simulations would require inclusion of a real O-RU with associated M-Plane support and also a real UE or test UE. + +In as much as the interoperability testing involves configuring the Near-RT RIC and the E2 Node, it shall be performed by means of the O1 interface. Configuration of the Near-RT RIC and E2 Node to operate in nominal state via the O1 interface, and configuring for policy guidance and enrichment data to the Near-RT RIC via the A1 interface are outside the scope of this test specification. + +![Figure 4.4.2-1 Illustration of interoperability between Near-RT RIC and E2 Node test setup. The diagram shows a System Management Object (SMO) containing a Non-RT RIC and a Near-RT RIC. The Near-RT RIC is connected to an O-eNB, O-CU-CP, and O-CU-UP via E2 interfaces. The O-CU-CP and O-CU-UP are connected to an O-DU via F1-C and F1-U interfaces respectively. The O-DU is connected to a RU and UE Simulator. A Protocol Analyzer is connected to the E2 interfaces for capturing. A 4G/5G Core is connected to the O-CU-UP. A SUT (System Under Test) is connected to the O-DU. Test Equipment (actual or simulator) is connected to the SUT.](866306db28209e9e635ceb2b3746d1d3_img.jpg) + +Figure 4.4.2-1 Illustration of interoperability between Near-RT RIC and E2 Node test setup. The diagram shows a System Management Object (SMO) containing a Non-RT RIC and a Near-RT RIC. The Near-RT RIC is connected to an O-eNB, O-CU-CP, and O-CU-UP via E2 interfaces. The O-CU-CP and O-CU-UP are connected to an O-DU via F1-C and F1-U interfaces respectively. The O-DU is connected to a RU and UE Simulator. A Protocol Analyzer is connected to the E2 interfaces for capturing. A 4G/5G Core is connected to the O-CU-UP. A SUT (System Under Test) is connected to the O-DU. Test Equipment (actual or simulator) is connected to the SUT. + +**Figure 4.4.2-1 Illustration of interoperability between Near-RT RIC and E2 Node test setup** + +Although the above test configuration diagrams illustrate O-CU-CP, O-CU-UP, O-DU as separate entities, the E2 Node may support a range of different RAN configurations similar to the list of cases described in “O-RAN.WG1.O-RAN-Architecture-Description” [8], Annex A.4. Examples include: + +- Standalone O-CU-CP connected to one or more standalone O-CU-UP and one or more standalone O-DU. Each logical node is considered as an E2 Node that presents an E2 interface to the Near-RT RIC. +- Combined O-CU-CP and O-CU-UP connected to one or more standalone O-DU. The combined O-CU-CP/O-CU-UP may present either a common E2 interface or individual E2 interfaces corresponding to the individual O-RAN components +- Combined O-CU-CP, O-CU-UP and O-DU. The combined node may present either a common E2 interface or individual E2 interfaces corresponding to the individual O-RAN components + +In all cases the different RAN components may initiate either independent E2 connections to the Near-RT RIC for each logical O-RAN component or may present a shared E2 interface and hence present the combined RAN components as a common E2 Node supporting services appropriate to more than one logical O-RAN component. + +The following RAN configurations where the Near-RT RIC is bundled with some or all of the O-RAN nodes as discussed in “O-RAN.WG1.O-RAN-Architecture-Description” [8], Annex A.4, are not addressed in this version of the specification. + +#### 4.4.2.1 System Under Test (Near-RT RIC and E2 Node) + +The System Under Test (SUT) consist of Near-RT RIC and E2 Node. + +The E2 Node can be of any of the following type: + +- O-CU-CP, O-CU-UP or O-DU +- Combined O-CU-CP, O-CU-UP and O-DU +- Combined O-CU-CP and O-CU-UP +- O-DU +- O-eNB + +For enabling interoperability testing, the Near-RT RIC and E2 Node have implemented the E2 interface, and the procedures specified in “O-RAN WG3: E2 Application Protocol” [2] that are required to perform testing of the applicable test cases. They may also support all or a subset of the E2 service models - E2SM-KPM, E2SM-NI and E2SM-RC as specified in “ORAN WG3: E2SM KPM” [5], “ORAN WG3: E2SM NI” [4], “ORAN WG3: E2SM RC” [6] and “ORAN WG3: E2SM CCC” [10] respectively. + +Each element of the SUT, Near-RT RIC and E2 Node, may comply to only a subset of E2 procedures and E2 service models. Therefore, only those testcases that relate to procedures supported by both Near-RT and E2 Node are relevant. This is noted on a case-by-case basis in testcases defined in clause 7. + +#### 4.4.2.2 Testing Tools + +The test setup has the SUT (Near-RT RIC and E2 Node) connected to other test equipments. These can be real or simulated UEs, O-RU, RAN elements, Core (EPC or 5GC) and Non-RT RIC to support scenarios appropriate for the E2 functionality being tested. An SMO with O1 interface is also included optionally if the Near-RT RIC, E2 Node or any of real or simulated elements need configuration or operation to function. + +In addition, a TAP interface can be used on E2 interface between Near-RT RIC and E2 Node to passively capture and analyze packets for test case validation. Alternatively, E2 logs from the SUT can be used for protocol analysis. + +# 5 Test Cases for Near-RT RIC + +## 5.1 General + +## 5.2 Conformance Test Cases + +### 5.2.1 E2AP Global Procedures + +#### 5.2.1.1 Test Cases for E2 Setup + +##### 5.2.1.1.1 E2 Setup (positive case) + +###### 5.2.1.1.1.1 Test Purpose + +The purpose of this test case is to test the E2 Setup procedure of the Near-RT RIC as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.1. The expected outcome is successful establishment of the signaling connection between E2 Node and Near-RT RIC. + +This testcase is mandatory if the DUT (Near-RT RIC) claims to support E2 Setup procedure. + +###### 5.2.1.1.1.2 Test Entrance Criteria + +- 1) The Test Simulator has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) support E2 Setup procedure. + +###### 5.2.1.1.1.3 Test Methodology + +###### 5.2.1.1.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. (SCTP initiation procedure has taken place before or is taking place with execution of this test case) +- 2) The DUT (Near-RT RIC) has the E2 service ready and available to receive E2 SETUP REQUEST from the Test Simulator. + +###### 5.2.1.1.1.3.2 Procedure + +Step 1. Initiate the E2 Setup procedure from Test Simulator to the DUT (Near-RT RIC) by sending E2 SETUP REQUEST Message. + +Step 2. At the Test Simulator the received and transmitted E2 messages are recorded in logs. + +###### 5.2.1.1.1.3.3 Expected result + +At the Test Simulator check the E2 response recorded in step 2 of procedure. + +The test is considered passed if following conditions are met: + +- 1) E2 Setup procedure is successfully completed. +- 2) E2 SETUP RESPONSE message is received. +- 3) E2 logs recorded in the Test Simulator are aligned with the message flow specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.1. + +#### 5.2.1.2 Test Cases for RESET procedure + +##### 5.2.1.2.1 Reset procedure (initiated by E2 Node) (positive case) + +###### 5.2.1.2.1.1 Test Purpose + +The purpose of this test case is to test Reset procedure of E2AP the initiated by E2 Node as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.2. The expected outcome is successful validation of RESET RESPONSE message from Near-RT RIC. + +This testcase is mandatory if the DUT (Near-RT RIC) claims to support Reset procedure. + +###### 5.2.1.2.1.2 Test Entrance Criteria + +- 1) The Test Simulator has the functionality to initiate Reset procedure. +- 2) The DUT (Near-RT RIC) supports Reset procedure. + +###### 5.2.1.2.1.3 Test Methodology + +###### 5.2.1.2.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. (SCTP initiation procedure has taken place before or is taking place with execution of this test case) +- 2) The DUT (Near-RT RIC) has the E2 service ready and available to receive E2 SETUP REQUEST from the Test Simulator. + +###### 5.2.1.2.1.3.2 Procedure + +Step 1. Initiate the Reset procedure from Test Simulator to the DUT (Near-RT RIC) by sending RESET REQUEST message as specified in [2] clause 9.1.2.5 with information elements as specified in table below. + +**Table 5.2.1.2.1-1** Information elements in RESET REQUEST message + +| IE Name | Reference | Configuration / Value | +|----------------|------------|-----------------------| +| Message Type | [2] 9.2.3 | RESET REQUEST | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) | +| Cause | [2] 9.2.1 | Any valid cause | + +Step 2. At the Test Simulator (E2 Node) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RESET RESPONSE as specified in [2] clause 9.1.2.6 and validated with information elements as specified in table below. + +**Table 5.2.1.2.1-2 Validation of IEs in RESET RESPONSE message** + +| IE Name | Reference | Presence | Validation | +|-------------------------|------------|----------|-----------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RESET RESPONSE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,...) same as received in RESET REQUEST | +| Criticality Diagnostics | [2] 9.2.2 | O | Optional, if present check for valid information elements | + +###### 5.2.1.2.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 is successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] Figure 8.3.2.2-1 + +##### 5.2.1.2.2 Reset procedure (initiated by Near-RT RIC) (positive case) + +###### 5.2.1.2.2.1 Test Purpose + +The purpose of this test case is to test Reset procedure of E2AP initiated by Near-RT RIC as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.2. The expected outcome is successful validation of RESET REQUEST message from Near-RT RIC. + +This testcase is mandatory if the DUT (Near-RT RIC) claims to support Reset procedure. + +###### 5.2.1.2.2.2 Test Entrance Criteria + +- 1) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support Reset procedure. +- 2) The DUT (Near-RT RIC) has the functionality to trigger Reset procedure. + +###### 5.2.1.2.2.3 Test Methodology + +###### 5.2.1.2.2.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. (SCTP initiation procedure has taken place before or is taking place with execution of this test case) +- 2) The DUT (Near-RT RIC) has the E2 service ready and available to receive E2 SETUP REQUEST from the Test Simulator. + +###### 5.2.1.2.2.3.2 Procedure + +Step 1. Initiate appropriate action in DUT (Near-RT RIC) to trigger Reset procedure. + +Step 2. At the Test Simulator (E2 Node) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RESET REQUEST as specified in [2] clause 9.1.2.5 and validated with information elements as specified in table below + +**Table 5.2.1.2.2-1 Validation of IEs in RESET REQUEST message** + +| IE Name | Reference | Presence | Validation | +|----------------|------------|----------|-----------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RESET REQUEST | +| Transaction ID | [2] 9.2.33 | M | Valid <i>Transaction ID</i> , INTEGER (0...255,...) | +| Cause | [2] 9.2.1 | M | Valid <i>Cause</i> information element | + +Step 4. If validation in step 3 is successful RESET RESPONSE message as specified in [2] clause 9.1.2.6 is sent to the DUT (Near-RT RIC) with parameters shown in table below + +**Table 5.2.1.2.2-2 Parameters in RESET RESPONSE message** + +| IE Name | Reference | Configuration / Value | +|-------------------------|------------|--------------------------------------------------------| +| Message Type | [2] 9.2.3 | RESET RESPONSE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,..) same as received in RESET REQUEST | +| Criticality Diagnostics | [2] 9.2.2 | Optional, not sent | + +###### 5.2.1.2.2.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 is successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] Figure 8.3.2.2-1 + +#### 5.2.1.3 Test Cases for Error Indication + +##### 5.2.1.3.1 Error Indication procedure + +###### 5.2.1.3.1.1 Test Purpose + +The purpose of this test case is to test the Error Indication procedure of the DUT (Near-RT RIC) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.4.4 and 8.3.3. The expected outcome is successful validation of ERROR INDICATION message from Near-RT RIC. + +This testcase is conditional mandatory if DUT claims to support Error Indication procedure. + +###### 5.2.1.3.1.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Control procedure with timer TRICcontrol +- 3) The DUT (Near-RT RIC) has ability to set RIC Control Ack Request IE in RIC CONTROL REQUEST message. +- 4) The RAN Function are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node), see clause 5.2.2.1.1.2. + +###### 5.2.1.3.1.3 Test Methodology + +###### 5.2.1.3.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the Test Simulator (E2 Node) with the agreed RAN Function been added. + +###### 5.2.1.3.1.3.2 Procedure + +Step 1. Initiate appropriate actions in DUT (Near-RT RIC) to trigger RIC Control procedure to the agreed RAN Function. + +Step 2. At the Test Simulator the received and transmitted E2 messages are recorded. + +Step 3. Received RIC CONTROL REQUEST message defined in [2] clause 9.1.1.8 is validated for the following E2AP information elements defined. + +**Table 5.2.1.3.1-1- Validation for RIC CONTROL REQUEST message** + +| IE/Group Name | Reference | Validation | +|-------------------------|------------|-----------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC CONTROL REQUEST | +| RIC Request ID | [2] 9.2.7 | Valid RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Same as the RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Call Process ID | [2] 9.2.18 | Not applicable.<br>This IE shall only be used when RIC CONTROL message is in response to RIC Subscription with RIC Action Type IE as "Insert" | +| RIC Control Header | [2] 9.2.20 | IEs defined in RAN Function specific E2 Service Model [4] [5] [6] | +| RIC Control Message | [2] 9.2.19 | IEs defined in RAN Function specific E2 Service Model [4] [5] [6] | +| RIC Control Ack Request | [2] 9.2.21 | Ack | + +Step 4. Do not send RIC CONTROL ACKNOWLEDGE message specified in [2] clause 9.1.1.9 to DUT (Near-RT RIC) and wait until Timer TRICcontrol expires in DUT (Near-RT RIC) + +Step 5. The Test Simulator does the following validation: + +The received message from DUT (Near-RT RIC) is ERROR INDICATION message specified in [2] clause 9.1.2.1 with following values + +**Table 5.2.1.3.1-2 Validation for ERROR INDICATION message** + +| IE Name | Presence | Reference | Configuration / Value | +|-------------------------|----------|------------|---------------------------------------------------------------------------------------------| +| Message Type | M | [2] 9.2.3 | ERROR INDICATION | +| Transaction ID | O | [2] 9.2.33 | INTEGER (0...255,...) Required if RIC Request ID IE is not present | +| RIC Request ID | O | [2] 9.2.7 | Required if Transaction ID IE is not present | +| RAN Function ID | O | [2] 9.2.8 | Same as the RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| Cause | O | [2] 9.2.1 | Valid Cause | +| Criticality Diagnostics | O | [2] 9.2.2 | Optional | + +###### 5.2.1.3.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure Step 5 is successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow as specified above. + +#### 5.2.1.4 Test Cases for RIC Service Update procedure + +##### 5.2.1.4.1 RIC Service Update procedure with RAN Function modified (positive case) + +###### 5.2.1.4.1.1 Test Purpose + +The purpose of this test case is to test the RIC Service Update procedure of the DUT (Near-RT RIC) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.4. This test is designed to be agnostic to the E2 Service Model and RAN functions supported by the Near-RT RIC. This test covers the scenario where a RAN Function is modified as part of the RIC Service Update procedure. The expected outcome is successful validation of the RIC SERVICE UPDATE ACKNOWLEDGE message from Near-RT RIC. + +This testcase is conditional mandatory if DUT claims support of RIC Service Update procedure. + +###### 5.2.1.4.1.2 Test Entrance Criteria + +- 1) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Service Update procedure. +- 2) The Test Simulator (E2 Node) has the functionality to initiate RIC Service Update procedure. + +###### 5.2.1.4.1.3 Test Methodology + +###### 5.2.1.4.1.3.1 conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the Test Simulator (E2 Node) with a RAN function supported by the Test Simulator. + +###### 5.2.1.4.1.3.2 Procedure + +Step 1. Initiate the RIC Service Update procedure from Test Simulator to the DUT (Near-RT RIC) by sending RIC SERVICE UPDATE message as specified in [2] clause 9.1.2.7 with information elements as specified in table below. + +**Table 5.2.1.4.1-1 Information elements in RIC SERVICE UPDATE message** + +| IE/Group Name | Reference | Configuration/Value | +|------------------------------------|------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SERVICE UPDATE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) | +| <b>RAN Functions Modified List</b> | | | +| >RAN Function Item | | | +| >>RAN Function ID | [2] 9.2.8 | INTEGER (1...4095) same as the one used in E2 Setup procedure | +| >>RAN Function Definition | [2] 9.2.23 | Valid <i>RAN Function Definition</i> as defined in the corresponding E2 Service Model [3] but different from the one used in E2 Setup procedure and supported by Near-RT RIC | +| >>RAN Function Revision | [2] 9.2.24 | Valid <i>RAN Function Revision</i> , INTEGER (0...4095) but different from the one used in E2 Setup procedure | +| >>RAN Function OID | [2] 9.2.31 | Valid <i>RAN Function OID</i> as specified in the corresponding E2 Service Model [3] | + +Step 2. At the Test Simulator (E2 Node) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RIC SERVICE UPDATE ACKNOWLEDGE as specified in [2] clause 9.1.2.8 and validated with information elements as specified in table below. The RAN Function ID sent in RIC SERVICE UPDATE ACKNOWLEDGE being in Accepted List. + +**Table 5.2.1.4.1-2 Validation of IEs in RIC SERVICE UPDATE ACKNOWLEDGE message** + +| IE/Group Name | Reference | Presence | Validation | +|------------------------------------|------------|----------|-------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RIC SERVICE UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,...) Same as in RIC SERVICE UPDATE message | +| <b>RAN Functions Accepted List</b> | | | RAN Function modified has been accepted | +| >RAN Function ID Item | | | | +| >>RAN Function ID | [2] 9.2.8 | M | INTEGER (1...4095) Same as in RIC SERVICE UPDATE message | +| >>RAN Function Revision | [2] 9.2.24 | M | INTEGER (0...4095) Same as in RIC SERVICE UPDATE message | + +###### 5.2.1.4.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure steps 3 is successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] figure 8.3.4.2-1. + +##### 5.2.1.4.2 RIC Service Update procedure with RAN Function deleted (positive case) + +###### 5.2.1.4.2.1 Test Purpose + +The purpose of this test case is to test the RIC Service Update procedure of the DUT (Near-RT RIC) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.4. This test is designed to be agnostic to the E2 Service Model and RAN functions supported by the Near-RT RIC. This test covers the scenario where a RAN Function is deleted as part of the RIC Service Update procedure. The expected outcome is successful validation of the RIC SERVICE UPDATE ACKNOWLEDGE message from Near-RT RIC. + +This testcase is conditional mandatory if DUT claims support of RIC Service Update procedure. + +###### 5.2.1.4.2.2 Test Entrance Criteria + +- 1) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Service Update procedure. +- 2) The Test Simulator (E2 Node) has the functionality to initiate RIC Service Update procedure. + +###### 5.2.1.4.2.3 Test Methodology + +###### 5.2.1.4.2.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the Test Simulator (E2 Node) with a RAN function supported by the Test Simulator + +###### 5.2.1.4.2.3.2 Procedure + +Step 1. Initiate a new RIC Service Update procedure from Test Simulator to the DUT (Near-RT RIC) by sending RIC SERVICE UPDATE message as specified in [2] clause 9.1.2.7 with information elements as specified in the table below. + +**Table 5.2.1.4.2-1 Information elements in RIC SERVICE UPDATE message** + +| IE/Group Name | Reference | Configuration/Value | +|-----------------------------------|------------|---------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SERVICE UPDATE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) | +| <b>RAN Functions Deleted List</b> | | | +| >RAN Function Item | | | +| >>RAN Function ID | [2] 9.2.8 | INTEGER (1...4095) same as the one used in E2 Setup procedure | +| >>RAN Function Revision | [2] 9.2.24 | INTEGER (0...4095) same as the one used in E2 Setup procedure | + +Step 2. At the Test Simulator (E2 Node) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RIC SERVICE UPDATE ACKNOWLEDGE as specified in [2] clause 9.1.2.8 and validated with information elements as specified in table below. The RAN Function ID sent in RIC SERVICE UPDATE ACKNOWLEDGE being in Accepted List. + +**Table 5.2.1.4.2-2 Validation of IEs in RIC SERVICE UPDATE ACKNOWLEDGE message** + +| IE/Group Name | Reference | Presence | Validation | +|------------------------------------|------------|----------|------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RIC SERVICE UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,..) Same as in RIC SERVICE UPDATE message | +| <b>RAN Functions Accepted List</b> | | | RAN Function modified has been accepted | +| >RAN Function ID Item | | | | +| >>RAN Function ID | [2] 9.2.8 | M | INTEGER (1...4095) Same as in RIC SERVICE UPDATE message | +| >>RAN Function Revision | [2] 9.2.24 | M | INTEGER (0...4095) Same as in RIC SERVICE UPDATE message | + +###### 5.2.1.4.2.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure steps 3 is successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] figure 8.3.4.2-1. + +##### 5.2.1.4.3 RIC Service Update procedure with RAN Function added (positive case) + +###### 5.2.1.4.3.1 Test Purpose + +The purpose of this test case is to test the RIC Service Update procedure of the DUT (Near-RT RIC) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.4. This test is designed to be agnostic to the E2 Service Model and RAN functions supported by the Near-RT RIC. This test covers the scenario where a RAN Function is added as part of the RIC Service Update procedure. The expected outcome is successful validation of the RIC SERVICE UPDATE ACKNOWLEDGE message from Near-RT RIC. + +This testcase is conditional mandatory if DUT claims support of RIC Service Update procedure. + +###### 5.2.1.4.3.2 Test Entrance Criteria + +- 1) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Service Update procedure. +- 2) The Test Simulator (E2 Node) has the functionality to initiate RIC Service Update procedure. + +##### 5.2.1.4.3.3 Test Methodology + +###### 5.2.1.4.3.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the Test Simulator (E2 Node) with a RAN function supported by the Test Simulator. + +###### 5.2.1.4.3.3.2 Procedure + +Step 1. Initiate a new RIC Service Update procedure from Test Simulator to the DUT (Near-RT RIC) by sending RIC SERVICE UPDATE message as specified in [2] clause 9.1.2.7 with information elements as specified in the table below + +Table 5.2.1.4.3-1 Information elements in RIC SERVICE UPDATE message + +| IE/Group Name | Reference | Configuration/Value | +|---------------------------------|------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SERVICE UPDATE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) | +| <b>RAN Functions Added List</b> | | | +| >RAN Function Item | | | +| >>RAN Function ID | [2] 9.2.8 | Valid <i>RAN Function Id</i> that doesn't exist in the DUT (Near-RT RIC), INTEGER (1...4095) | +| >>RAN Function Definition | [2] 9.2.23 | Valid <i>RAN Function Definition</i> for a <i>RAN Function</i> doesn't exist in the DUT (Near-RT RIC) as defined in the corresponding E2 Service Model [3] and supported by Near-RT RIC. | +| >>RAN Function Revision | [2] 9.2.24 | Valid <i>RAN Function Revision</i> , INTEGER (0...4095) | +| >>RAN Function OID | [2] 9.2.31 | Valid <i>RAN Function OID</i> as specified in the corresponding E2 Service Model [3] | + +Step 2. At the Test Simulator (E2 Node) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RIC SERVICE UPDATE ACKNOWLEDGE as specified in [2] clause 9.1.2.8 and validated with information elements as specified in table below. The RAN Function ID sent in RIC SERVICE UPDATE ACKNOWLEDGE in Accepted List. + +Table 5.2.1.4.3-2 Validation of IEs in RIC SERVICE UPDATE ACKNOWLEDGE message + +| IE/Group Name | Reference | Presence | Validation | +|------------------------------------|------------|----------|-------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RIC SERVICE UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,...) Same as in RIC SERVICE UPDATE message | +| <b>RAN Functions Accepted List</b> | | | RAN Function modified has been accepted | +| >RAN Function ID Item | | | | +| >>RAN Function ID | [2] 9.2.8 | M | INTEGER (1...4095) Same as in RIC SERVICE UPDATE message | +| >>RAN Function Revision | [2] 9.2.24 | M | INTEGER (0...4095) Same as in RIC SERVICE UPDATE message | + +###### 5.2.1.4.3.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure steps 3 is successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] figure 8.3.4.2-1. + +#### 5.2.1.5 Test Cases for E2 Node Configuration Update procedure + +##### 5.2.1.5.1 E2 Node Configuration Update procedure with E2 Node configuration added (positive) + +##### 5.2.1.5.1.1 Test Purpose + +The purpose of this test case is to test the E2 Node Configuration Update procedure of the DUT (Near-RT RIC) as specified in "O-RAN WG3: E2 Application Protocol" [2] clause 8.3.5. This test is designed to test the scenario where an E2 Node component configuration is added as a part of update procedure. + +The expected outcome of this test is DUT (Near-RT RIC) successfully acknowledging the update. + +This testcase is conditionally mandatory if the DUT (Near-RT RIC) claims to support E2 Node Configuration Update procedure. + +##### 5.2.1.5.1.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) supports E2 Node Configuration Update procedure. +- 3) Test Simulator (E2 Node) has functionality to trigger E2 Node Configuration Update procedure. + +##### 5.2.1.5.1.3 Test Methodology + +###### 5.2.1.5.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The DUT (Near-RT RIC) has successfully completed E2 Setup procedure but does not include the E2 Node configuration used in the procedure described in next section. + +###### 5.2.1.5.1.3.2 Procedure + +Step 1. Initiate the E2 Node Configuration Update procedure from Test Simulator to the DUT (Near-RT RIC) by sending E2 NODE CONFIGURATION UPDATE message as specified in [2] clause 9.1.2.11 with information elements for a E2 Node component addition shown in example table below. + +**Table 5.2.1.5.1-1 Information elements in E2 NODE CONFIGURATION UPDATE message** + +| IE / Message value | Reference | Configuration / Value | +|------------------------------------------------|---------------------------------------|-----------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | E2 NODE CONFIGURATION UPDATE | +| Transaction ID | [2] 9.2.33 | INTEGER (0..255, ...) any valid value. | +| E2 Node Component Configuration Addition List | List with one item as specified below | | +| >E2 Node Component Configuration Addition Item | | | +| >>E2 Node Component Interface Type | [2] 9.2.26 | ENUMERATED (ng, xn, e1, f1, w1, s1, x2, ...) Interface Type = "f1" used as a valid example | +| >>E2 Node Component ID | [2] 9.2.32 | Valid gNB-DU ID | +| >>E2 Node Component Configuration | [2] 9.2.27 | OCTECT STRINGS representing F1 SETUP REQUEST and F1 SETUP RESPONSE for the added F1 interface | + +Step 2. At the Test Simulator the received and transmitted E2 message is recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE as specified in [2] clause 9.1.2.12 and validated with the information elements specified in table below. + +**Table 5.2.1.5.1-2 Validation of IEs in E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message** + +| IE Name | Reference | Presence | Validation | +|------------------------------------------------------------|------------|----------|---------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,...) same as in E2 NODE CONFIGURATION UPDATE | +| E2 Node Component Configuration Addition Acknowledge List | | M | | +| >E2 Node Component Configuration Addition Acknowledge Item | | | | +| >>E2 Node Component Interface Type | [2] 9.2.26 | M | Interface Type = "f1" same as in E2 NODE CONFIGURATION UPDATE | +| >>E2 Node Component ID | [2] 9.2.32 | M | gNB-DU ID same as in E2 NODE CONFIGURATION UPDATE | +| >>E2 Node Component Configuration Acknowledge | [2] 9.2.28 | M | Success or failure with Cause | + +###### 5.2.1.5.1.3.3 Expected results + +The test is considered passed if + +- 1) Validations in test procedure Step 3. +- 2) Step 2 E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in “O-RAN WG3: E2 Application Protocol” [2] 8.3.5.2 + +##### 5.2.1.5.2 E2 Node Configuration Update procedure with E2 Node configuration updated (positive) + +###### 5.2.1.5.2.1 Test Purpose + +The purpose of this test case is to test the E2 Node Configuration Update procedure of the DUT (Near-RT RIC) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.5. This test is designed to test the scenario where an E2 Node component configuration is updated as a part of update procedure. + +The expected outcome of this test is DUT (Near-RT RIC) successfully acknowledging the update. + +This testcase is conditionally mandatory if the DUT (Near-RT RIC) claims to support E2 Node Configuration Update procedure. + +###### 5.2.1.5.2.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) supports E2 Node Configuration Update procedure. +- 3) Test Simulator (E2 Node) has functionality to trigger E2 Node Configuration Update procedure. + +###### 5.2.1.5.2.3 Test Methodology + +###### 5.2.1.5.2.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The DUT (Near-RT RIC) has successfully completed E2 Setup procedure and includes an E2 Node configuration that will be updated by the procedure described in next section. + +###### 5.2.1.5.2.3.2 Procedure + +Step 1. Initiate the E2 Node Configuration Update procedure from Test Simulator to the DUT (Near-RT RIC) by sending E2 NODE CONFIGURATION UPDATE message as specified in [2] clause 9.1.2.11 with information elements for an E2 Node component updated as shown in example table below. + +**Table 5.2.1.5.2-1 Information elements in E2 NODE CONFIGURATION UPDATE message** + +| IE / Message value | Reference | Configuration / Value | +|----------------------------------------------|---------------------------------------|---------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | E2 NODE CONFIGURATION UPDATE | +| Transaction ID | [2] 9.2.33 | INTEGER (0..255, ...) any valid value. | +| E2 Node Component Configuration Update List | List with one item as specified below | | +| >E2 Node Component Configuration Update Item | | | +| >>E2 Node Component Interface Type | [2] 9.2.26 | ENUMERATED (ng, xn, e1, f1, w1, s1, x2, ...) Interface Type = “f1” used as a valid example | +| >>E2 Node Component ID | [2] 9.2.32 | Use gNB-DU ID of the existing E2 Node intended to be updated | +| >>E2 Node Component Configuration | [2] 9.2.27 | OCTET STRINGS representing F1 SETUP REQUEST and F1 SETUP RESPONSE with updated information. | + +Step 2. At the Test Simulator the received and transmitted E2 message is recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE as specified in [2] clause 9.1.2.12 and validated with information elements specified in table below. + +**Table 5.2.1.5.2-2 Validation of IEs in E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message** + +| IE Name | Reference | Presence | Validation | +|----------------------------------------------------------|------------|----------|---------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,...) same as in E2 NODE CONFIGURATION UPDATE | +| E2 Node Component Configuration Update Acknowledge List | | M | | +| >E2 Node Component Configuration Update Acknowledge Item | | | | +| >>E2 Node Component Interface Type | [2] 9.2.26 | M | Interface Type = "f1" same as in E2 NODE CONFIGURATION UPDATE | +| >>E2 Node Component ID | [2] 9.2.32 | M | gNB-DU ID same as in E2 NODE CONFIGURATION UPDATE | +| >>E2 Node Component Configuration Acknowledge | [2] 9.2.28 | M | Success or failure with Cause | + +###### 5.2.1.5.2.3.3 Expected results + +The test is considered passed if + +- 1) Validations in test procedure Step 3. +Step 2 E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in "O-RAN WG3: E2 Application Protocol" [2] 8.3.5.2 + +##### 5.2.1.5.3 E2 Node Configuration Update procedure with E2 Node configuration removed (positive) + +###### 5.2.1.5.3.1 Test Purpose + +The purpose of this test case is to test the E2 Node Configuration Update procedure of the DUT (Near-RT RIC) as specified in "O-RAN WG3: E2 Application Protocol" [2] clause 8.3.5. This test is designed to test the scenario where an E2 Node component configuration is removed as a part of update procedure. + +The expected outcome of this test is DUT (Near-RT RIC) successfully acknowledging the update. + +This testcase is conditionally mandatory if the DUT (Near-RT RIC) claims to support E2 Node Configuration Update procedure. + +##### 5.2.1.5.3.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) supports E2 Node Configuration Update procedure. +- 3) Test Simulator (E2 Node) has functionality to trigger E2 Node Configuration Update procedure. + +###### 5.2.1.5.3.3 Test Methodology + +###### 5.2.1.5.3.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface +- 2) The DUT (Near-RT RIC) has successfully completed E2 Setup procedure and includes an E2 Node configuration that will be removed by the procedure described in next section. + +###### 5.2.1.5.3.3.2 Procedure + +Step 1. Initiate the E2 Node Configuration Update procedure from Test Simulator to the DUT (Near-RT RIC) by sending E2 NODE CONFIGURATION UPDATE message as specified in [2] clause 9.1.2.11 with information elements for an E2 Node component removed as shown in example table below. + +**Table 5.2.1.5.3-1 Information elements in E2 NODE CONFIGURATION UPDATE message** + +| IE / Message value | Reference | Configuration / Value | +|-----------------------------------------------|---------------------------------------|--------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | E2 NODE CONFIGURATION UPDATE | +| Transaction ID | [2] 9.2.33 | INTEGER (0..255, ...) any valid value. | +| E2 Node Component Configuration Removal List | List with one item as specified below | | +| >E2 Node Component Configuration Removal Item | | | +| >>E2 Node Component Interface Type | [2] 9.2.26 | ENUMERATED (ng, xn, e1, f1, w1, s1, x2, ...) Interface Type = "f1" used as a valid example | +| >>E2 Node Component ID | [2] 9.2.32 | Use gNB-DU ID of the existing E2 Node intended to be updated | + +Step 2. At the Test Simulator the received and transmitted E2 message is recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE as specified in [2] clause 9.1.2.12 and validated with the information elements specified in table below. + +**Table 5.2.1.5.3-2 Validation of IEs in E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message** + +| IE Name | Reference | Presence | Validation | +|-----------------------------------------------------------|------------|----------|------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,...) same as received in E2 NODE CONFIGURATION UPDATE | +| E2 Node Component Configuration Removal Acknowledge List | | M | | +| >E2 Node Component Configuration Removal Acknowledge Item | | | | +| >>E2 Node Component Interface Type | [2] 9.2.26 | M | Interface Type = "f1" same as in E2 NODE CONFIGURATION UPDATE | +| >>E2 Node Component ID | [2] 9.2.32 | M | gNB-DU ID same as in E2 NODE CONFIGURATION UPDATE | +| >>E2 Node Component Configuration Acknowledge | [2] 9.2.28 | M | Success or failure with Cause | + +###### 5.2.1.5.3.3.3 Expected results + +The test is considered passed if + +- 1) Validations in test procedure Step 3. +- 2) Step 2 E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in "O-RAN WG3: E2 Application Protocol" [2] 8.3.5.2 + +#### 5.2.1.6 Test Cases for E2 Connection Update procedure + +##### 5.2.1.6.1 E2 Connection Update procedure with TNL Association added (positive case) + +##### 5.2.1.6.1.1 Test Purpose + +The purpose of this test case is to test the E2 Connection Update procedure of the DUT (Near-RT RIC) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.6. The expected outcome is successful validation of the E2 CONNECTION UPDATE message from Near-RT RIC and establishment of a new TNL Association. + +This testcase is conditional mandatory if DUT claims support E2 Connection Update procedure and multiple TNLAs over E2. + +##### 5.2.1.6.1.2 Test Entrance Criteria + +- 1) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support E2 Connection Update procedure and multiple TNLAs over E2. +- 2) The DUT (Near-RT RIC) has the functionality to trigger E2 Connection Update procedure for addition of a new TNL Association. + +##### 5.2.1.6.1.3 Test Methodology + +###### 5.2.1.6.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the Test Simulator (E2 Node). + +###### 5.2.1.6.1.3.2 Procedure + +Step 1. Initiate appropriate action in DUT (Near-RT RIC) to trigger E2 Connection Update procedure for addition of a new TNL Association. + +Step 2. At the Test Simulator (E2 Node) the received, transmitted E2 messages and SCTP Transport level messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is E2 CONNECTION UPDATE as specified in [2] clause 9.1.2.14 and validated with information elements as specified in table below. + +**Table 5.2.1.6.1-1 Validation of parameters in E2 Connection Update message** + +| IE Name | Reference | Presence | Validation | +|----------------------------------|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | E2 CONNECTION UPDATE | +| Transaction ID | [2] 9.2.33 | M | Valid <i>Transaction ID</i> , INTEGER (0...255,..) | +| <b>E2 Connection To Add List</b> | | | | +| >E2 Connection to Add Item IEs | | | One item | +| >>Transport Layer Information | [2] 9.2.29 | M | Valid <i>Transport Layer Information</i> , BIT STRING for Transport Layer Address (Mandatory, SIZE(1...160,...)) and Transport Layer Port (Optional, SIZE(16) ) Different from transport layer information used in initial SCTP association | +| >>TNL Association Usage | [2] 9.2.30 | M | Valid <i>TNL Association Usage</i> , ENUMERATED (ric service, support functions, both,..) | + +Step 4. The Test Simulator (E2 Node) initiates and establishes a new SCTP connection towards the Transport Layer Information (address and port) provided in E2 CONNECTION UPDATE message. + +Step 5. Based on SCTP Transport Level messages recoded, the Test Simulator (E2 Node) validates the SCTP establishment in Step 4. + +Step 6. If validation in steps 3 and 5 are successful, E2 CONNECTION UPDATE ACKNOWLEDGE message as specified in [2] clause 9.1.2.15 is sent to DUT (Near-RT RIC) with parameters shown in table below. + +**Table 5.2.1.6.1-2 Validation for E2 CONNECTION UPDATE ACKNOWLEDGE message** + +| IE/Group Name | Reference | Configuration/Value | +|---------------------------------|------------|------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | E2 CONNECTION UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) same as in E2 CONNECTION UPDATE message | +| <b>E2 Connection Setup List</b> | | | +| >E2 Connection Setup Item IEs | | | +| >>Transport Layer Information | [2] 9.2.29 | Same BIT STRING as in E2 CONNECTION UPDATE message | +| >>TNL Association Usage | [2] 9.2.30 | Same TNL Association Usage, , ENUMERATED (ric service, support functions, both,..), as in E2 CONNECTION UPDATE message | + +Step 7. The Test Simulator (E2 Node) triggers E2 Node Configuration Update procedure on the new TNL Association. Validation of the E2 Node Configuration Update procedure is out of the scope of this test and can be referred in clause 5.2.1.5.3. + +###### 5.2.1.6.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure steps 3 and 5 are successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] figure 8.3.6.2-1. + +#### 5.2.1.7 Test Cases for E2 Removal procedure + +##### 5.2.1.7.1 E2 Removal procedure initiated by E2 Node (positive case) + +###### 5.2.1.7.1.1 Test Purpose + +The purpose of this test case is to test the E2 Node initiated E2 Removal procedure of Near-RT RIC as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.7. The expected outcome of this test is successful removal of E2 signaling connection between the Near-RT RIC and the E2 Node. + +This testcase is mandatory if the DUT (Near-RT RIC) claims to support E2 Removal procedure. + +##### 5.2.1.7.1.2 Test Entrance Criteria + +- 1) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support E2 Removal procedure. +- 2) The Test Simulator (E2 Node) has the functionality to trigger E2 Removal procedure. + +##### 5.2.1.7.1.3 Test Methodology + +###### 5.2.1.7.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before the execution of this test case). +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) has successfully completed E2 Setup procedure. + +###### 5.2.1.7.1.3.2 Procedure + +Step 1. Initiate the E2 Removal procedure from Test Simulator (E2 Node) to the DUT (Near-RT RIC) by sending E2 REMOVAL REQUEST message as specified in [2] clause 9.1.1.17 with information elements as specified in table below. + +**Table 5.2.1.7.1-1 Parameters in in E2 REMOVAL REQUEST message** + +| IE/Group Name | Reference | Configuration / Value | +|----------------|-----------|-----------------------| +| Message Type | 9.2.3 | REMOVAL REQUEST | +| Transaction ID | 9.2.33 | INTEGER (0..255, ...) | + +Step 2. At the Test Simulator (E2 Node) the transmitted, received E2 messages and SCTP Transport level messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is E2 REMOVAL RESPONSE as specified in [2] clause 9.2.1.18 and validated with information elements are as specified in table below: + +**Table 5.2.1.7.1-2 Validation for RESET RESPONSE message** + +| IE/Group Name | Presence | Reference | Validation | +|-------------------------|----------|-----------|-----------------------------------------------------------------| +| Message Type | M | 9.2.3 | | +| Transaction ID | M | 9.2.33 | INTEGER (0..255, ...) Same value as the one in REMOVAL REQUEST. | +| Criticality Diagnostics | O | 9.2.2 | Will not be used in this test | + +Step 4. Based on SCTP Transport level messages recorded in Step 2 validate that the DUT (Near-RT RIC) successfully acknowledge the termination of the SCTP connection initiated by the Test Simulator (E2 Node) and sends SHUTDOWN\_ACK message + +###### 5.2.1.7.1.3.3 Expected results + +The test is considered passed if + +- 1) Validations in test procedure Step 4 and Step 4 are successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] figure 8.3.7.2-1. + +##### 5.2.1.7.2 E2 Removal procedure initiated by Near-RT RIC (positive case) + +###### 5.2.1.7.2.1 Test Purpose + +The purpose of this test case is to test the Near-RT RIC initiated E2 Removal procedure of Near-RT RIC as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.7. The expected outcome of this test is successful removal of E2 signaling connection between the Near-RT RIC and the E2 Node + +This testcase is mandatory if the DUT (E2 Node) claims to support E2 Removal procedure. + +###### 5.2.1.7.2.2 Test Entrance Criteria + +- 1) The DUT (Near-RT RIC) and Test Simulator (E2 Node) supports E2 Removal procedure. +- 2) The DUT (Near-RT RIC) has the functionality to trigger E2 Removal procedure. + +###### 5.2.1.7.2.3 Test Methodology + +###### 5.2.1.7.2.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before the execution of this test case). +- 2) The Test Simulator (E2 Node) and DUT (Near-RT RIC) has successfully completed E2 Setup procedure. + +###### 5.2.1.7.2.3.2 Procedure + +Step 1. Initiate appropriate action in DUT (Near-RT RIC) to trigger E2 Removal procedure. + +Step 2. At the Test Simulator (E2 Node) the transmitted, received E2 messages and SCTP Transport level messages are recorded. + +Step 3. The Test Simulator (E2 Node) does the following validation: + +The received message is E2 REMOVAL REQUEST as specified in [2] clause 9.1.1.17 and validated with information elements as specified in table below: + +**Table 5.2.1.7.2-1 Validation of IEs in E2 REMOVAL REQUEST message** + +| IE/Group Name | Presence | Reference | Configuration / Value | +|----------------|----------|-----------|-----------------------| +| Message Type | M | 9.2.3 | REMOVAL REQUEST | +| Transaction ID | M | 9.2.33 | INTEGER (0..255, ...) | + +Step 4. If validation in step 3 is successful, E2 REMOVAL RESPONSE message as specified in [2] clause 9.1.1.18 is sent to the DUT (Near-RT RIC) with parameters shown in table below + +**Table 5.2.1.7.2-2 Parameters in E2 RESET RESPONSE message** + +| IE/Group Name | Reference | Validation | +|-------------------------|-----------|--------------------------------------------------------------------| +| Message Type | 9.2.3 | | +| Transaction ID | 9.2.33 | INTEGER (0..255, ...)<br>Same value as the one in REMOVAL REQUEST. | +| Criticality Diagnostics | 9.2.2 | Will not be used in this test | + +Step 5. Based on SCTP Transport level messages recorded in Step 2 validate that the DUT (Near-RT RIC) initiates and complete the termination of the SCTP connection by sending the SHUTDOWN\_COMPLETE message + +###### 5.2.1.7.2.3.3 Expected results + +The test is considered passed if + +- 1) Validations in test procedure Step 4 and Step 5 are successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] figure 8.3.7.2-2 + +### 5.2.2 E2AP Functional Procedures + +#### 5.2.2.1 Test Cases for RIC Subscription procedure + +##### 5.2.2.1.1 RIC Subscription procedure for single RIC action (positive) + +###### 5.2.2.1.1.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription procedure of Near-RT RIC for single RIC action as specified in [2] clause 8.2.1. This test is designed to be agnostic to the E2 Service Model and RAN functions. The RAN Function and RAN Function definition to which RIC Subscribes are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). The expected outcome of this test is successful RIC Subscription by Near-RT RIC. + +Test cases for RIC Subscription procedures for specific E2 Service Models and functionalities are defined in sections dedicated for Service Models which will reuse initial conditions, test procedures, and validation steps specified in this section for base E2AP functionality. + +This testcase is mandatory if the DUT claims to support E2AP RIC Subscription procedure. + +###### 5.2.2.1.1.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Subscription procedure. +- 3) The RAN Function to which RIC subscribes and the RAN Function definition are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). An example of the agreed RAN Function Definition IE as per configuration is shown in table below. + +**Table 5.2.2.1.1-1 E2SM KPM RAN Function Definition Profile IE profile for this test** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|----------------------------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 1 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement | +| > RIC Report Action Format Type | [5] 8.3.5 | 1 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5]8.3.9 | Name of one Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +- 4) DUT (Near-RT RIC) has functionality to trigger subscription to the RAN Function agreed. + +###### 5.2.2.1.1.3 Test Methodology + +###### 5.2.2.1.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup Request initiated from the Test Simulator (E2 Node) with the agreed RAN Function. + +###### 5.2.2.1.1.3.2 Procedure + +Step 1. Initiate appropriate actions in DUT (Near-RT RIC) to trigger RIC Subscription procedure to the agreed RAN Function. + +Step 2. At the Test Simulator the received and transmitted E2 messages are recorded. + +Step 3. Received RIC SUBSCRIPTION REQUEST message defined in [2] clause 9.1.1.1 is validated for the following E2AP information elements defined. + +**Table 5.2.2.1.1-2 Validation for RIC SUBSCRIPTION REQUEST message** + +| IE/Group Name | Reference | Validation | +|-------------------------------|-------------|---------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.1.1.1 | RIC SUBSCRIPTION REQUEST | +| RIC Request ID | [2] 9.1.1.1 | Valid RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Should be same as RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Subscription Details | | | +| >RIC Event Trigger Definition | [2] 9.2.9 | Validation for IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | +| >Sequence of Actions | | | +| >>RIC Action ID | [2] 9.2.10 | Valid RIC Action ID, INTEGER (0..255) | +| >>RIC Action Type | [2] 9.2.11 | Valid RIC Action Type, ENUMERATED (Insert, Report, Policy, ...) | +| >>RIC Action Definition | [2] 9.2.12 | Validation for IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | + +Step 4. If validation in step 3 is successful RIC SUBSCRIPTION RESPONSE message specified in [2] clause 9.2.1.1 is sent to the DUT (Near-RT RIC) with parameters shown in table below. + +**Table 5.2.2.1.1-3 Parameters in RIC SUBSCRIPTION RESPONSE message** + +| IE/Group Name | IE type and reference | Semantics description | +|---------------------------|-----------------------|-------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION RESPONSE | +| RIC Request ID | [2] 9.2.7 | Received RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Received RAN Function ID | +| RIC Actions Admitted List | | | +| >RIC Action ID | [2] 9.2.10 | Received Action ID requested included in <i>RIC Actions Admitted List</i> IE. | + +###### 5.2.2.1.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 is successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] clause 8.2.1.2. + +#### 5.2.2.2 Test Cases for RIC Subscription Delete + +##### 5.2.2.2.1 RIC Subscription Delete procedure (positive) + +###### 5.2.2.2.1.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription delete procedure of the Near-RT RIC as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.2. This test is designed to be agnostic to the E2 Service Model and RAN functions. This testcase validates RIC Subscription Delete procedure of E2AP. The RAN Function and RAN Function definition to which RIC Subscribes are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). + +The expected outcome of this test is successful deletion of RIC Subscription by Near-RT RIC. + +This testcase is mandatory if the DUT claims to support RIC Subscription Delete procedure. + +###### 5.2.2.2.1.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Subscription Delete procedure. + +- 3) The RAN Function the RIC subscribes to and the RAN Function definition are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). An example of the agreed RAN Function Definition IE as per configuration is shown in table below. + +**Table 5.2.2.2.1-1 E2SM KPM RAN Function Definition Profile IE profile for this test** + +| Name | Reference | Configuration / Value | +|---------------------------------|-----------|-------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | + +- 4) DUT (Near-RT RIC) has functionality to trigger RIC subscription delete to the RAN Function agreed. + +##### 5.2.2.2.1.3 Test Methodology + +###### 5.2.2.2.1.3.1 Initial conditions + +- 1) The DUT (Near-RT RIC) has successfully completed E2 Setup procedure with the agreed RAN Function ID +- 2) The DUT (Near-RT RIC) has successfully completed RIC subscription procedure with the agreed RIC request ID. + +###### 5.2.2.2.1.3.2 Procedure + +Step 1. Initiate appropriate actions in DUT (Near-RT RIC) to trigger RIC Subscription Delete procedure for the agreed RAN Function. + +Step 2. At the Test Simulator the received and transmitted E2 message is recorded. + +Step 3. Received RIC SUBSCRIPTION DELETE REQUEST message defined in [2] clause 9.1.1.4 is validated for the following E2AP information elements defined. + +**Table 5.2.2.2.1-2 Validation for RIC SUBSCRIPTION DELETE REQUEST message** + +| IE/Group Name | Reference | Validation | +|-----------------|-----------|---------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION DELETE REQUEST | +| RIC Request ID | [2] 9.2.7 | Valid RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Should be same as RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | + +Step 4. If validation in step 3 is successful RIC SUBSCRIPTION DELETE RESPONSE message specified in [2] 9.1.1.5 is sent to the DUT (Near-RT RIC) with parameters shown in table below. + +**Table 5.2.2.2.1-3 Parameters in RIC SUBSCRIPTION DELETE RESPONSE message** + +| IE/Group Name | IE type and reference | Semantics description | +|-----------------|-----------------------|----------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION DELETE RESPONSE | +| RIC Request ID | [2] 9.2.7 | Received RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Received RAN Function ID | + +###### 5.2.2.2.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 is successful. + +- 2) Step 2 E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.2.2 + +#### 5.2.2.3 Test Cases for RIC Subscription Delete Required procedure + +##### 5.2.2.3.1 RIC Subscription Delete Required procedure (positive) + +###### 5.2.2.3.1.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription Delete Required procedure of the DUT (Near-RT RIC) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.2A. This test is designed to be agnostic to the E2 Service Model and RAN functions decided to be used. The RAN Function and RAN Function definition to which RIC Subscribes are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). + +The expected outcome of this test is DUT (Near-RT RIC) processing RIC SUBSCRIPTION DELETE REQUIRED message successfully and subsequently initiating RIC Subscription Delete procedure to Test Simulator (E2 Node). + +This testcase is conditionally mandatory if the DUT (Near-RT RIC) claims to support RIC Subscription Delete Required procedure. + +###### 5.2.2.3.1.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) supports RIC Subscription Delete Required procedure. +- 3) The RAN Function the RIC subscribes to and the RAN Function definition are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). An example of the agreed RAN Function Definition IE as per configuration is shown in table below. + +**Table 5.2.2.3.1-1 E2SM KPM RAN Function Definition Profile IE profile for this test** + +| IE Name | Reference | Configuration / Value | +|---------------------------------|-----------|-------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | + +- 4) Test Simulator (E2 Node) has functionality to trigger RIC Subscription Delete Required procedure. + +##### 5.2.2.3.1.3 Test Methodology + +###### 5.2.2.3.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has successfully completed E2 Setup procedure and RIC subscription procedure with the agreed RAN Function ID and RIC request ID. + +###### 5.2.2.3.1.3.2 Procedure + +Step 1. Initiate the RIC Subscription Delete Required procedure from Test Simulator to the DUT (Near-RT RIC) by sending RIC SUBSCRIPTION DELETE REQUIRED message as specified in [2] clause 9.1.1.6A with information elements as specified in table below. + +**Table 5.2.2.3.1-2 Information element in RIC SUBSCRIPTION DELETE REQUIRED message** + +| IE / Message value | Reference | Configuration / Value | +|-----------------------------------------|-----------|-------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION DELETE REQUIRED | +| List of RIC Subscriptions To Be Removed | | One item | +| RIC Request ID | [2] 9.2.7 | Should be same as the RIC Request ID used during subscription procedure | +| RAN Function ID | [2] 9.2.8 | Should be same as RAN Function ID used during subscription | +| Cause | [2] 9.2.1 | Any valid cause | + +Step 2. At the Test Simulator the received and transmitted E2 message is recorded. + +Step 3. RIC Subscription Delete procedure initiated by DUT (Near-RT RIC) is validated as per clause 5.2.2.1.1.3.2 Steps 3 and 4. + +Step 4: Validation is done to confirm that RIC SUBSCRIPTION DELETE message has the same RIC Request ID and RAN Function ID as received in RIC SUBSCRIPTION DELETE REQUIRED message. + +###### 5.2.2.3.1.3.3 Expected results + +- 1) The test is considered passed if +- 2) Validations in test procedure Step 3 and Step 4 are successful. +- 3) Step 2 E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.2A.2 + +#### 5.2.2.4 Test Cases for RIC Indication procedure + +##### 5.2.2.4.1 RIC Indication procedure for REPORT Service (positive) + +###### 5.2.2.4.1.1 Test Purpose + +The purpose of this test case is to test the RIC Indication procedure of Near-RT RIC as specified in [2] clause 8.2.3. This test is designed to be agnostic to the E2 Service Model and RAN functions. The RAN Function and RAN Function definition to which RIC Subscribes are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). The expected outcome of this test is successful reception of the RIC INDICATION message associated with a REPORT Service from the E2 Node. + +Test cases for RIC Indication procedures for specific E2 Service Models and functionalities are defined in sections dedicated for Service Models. These will reuse initial conditions, test procedures, and validation steps specified in this section for base E2AP functionality. + +This testcase is mandatory if the DUT (Near-RT RIC) claims to support E2AP RIC Indication procedure. + +###### 5.2.2.4.1.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure and accept RIC Subscription procedure for REPORT Service. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Indication procedure. +- 3) The RAN Function to which RIC subscribes and the RAN Function definition are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node), see clause 5.2.2.1. + +- 4) Test Simulator has functionality to trigger RIC Indication procedure. + +###### 5.2.2.4.1.3 Test Methodology + +###### 5.2.2.4.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the Test Simulator (E2 Node) with the agreed RAN Function been added. +- 3) DUT (Near-RT RIC) has already initiated a RIC Subscription procedure to the Test Simulator (E2 Node) and received a successful response, at least one successful action associated with REPORT Service exists. The RIC Event Trigger Definition and RIC Action Definition IEs specific to E2 Service Models are not defined in the scope of this test. + +###### 5.2.2.4.1.3.2 Procedure + +Step 1. Test Simulator sends RIC INDICATION message to the DUT (Near-RT RIC) as specified in [2] clause 9.1.1.7 with parameters shown in table below. The sent and received E2 messages are recorded. + +**Table 5.2.2.4.1-1 RIC INDICATION IE Profile for this test message** + +| IE/Group Name | Reference | Configuration/ Value | +|------------------------|------------|--------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC INDICATION | +| RIC Request ID | [2] 9.2.7 | Same as the RIC Request ID received in the corresponding RIC subscription procedure | +| RAN Function ID | [2] 9.2.8 | Same as the RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Action ID | [2] 9.2.10 | Same as the RIC Action ID received in the corresponding RIC subscription procedure | +| RIC Indication SN | [2] 9.2.14 | Not used.<br>Sequence Number is optional and not used in this test case | +| RIC Indication Type | [2] 9.2.15 | Report | +| RIC Indication Header | [2] 9.2.17 | IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | +| RIC Indication Message | [2] 9.2.16 | IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | +| RIC Call process ID | [2] 9.2.18 | Not applicable.<br>This IE shall only be used when RIC INDICATION message is in response to RIC Subscription with RIC Action Type IE as "Insert" | + +###### 5.2.2.4.1.3.3 Expected results + +The test is considered passed if + +- 1) The DUT (Near-RT RIC) correctly receives the RIC INDICATION message from the Test Simulator. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] clause 8.2.3.2. + +#### 5.2.2.5 Test Cases for RIC Control procedure + +##### 5.2.2.5.1 RIC Control procedure for CONTROL Service (positive) + +###### 5.2.2.5.1.1 Test Purpose + +The purpose of this test case is to test the RIC Control procedure of Near-RT RIC as specified in [2] clause 8.2.4. This test is designed to be agnostic to the E2 Service Model and RAN functions. The RAN Function and RAN Function definition to which RIC Subscribes are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). The expected outcome of this test is successful RIC Control procedure from Near-RT RIC to the E2 Node. + +Test cases for RIC Control procedures for specific E2 Service Models and functionalities are defined in sections dedicated for Service Models. These will reuse initial conditions, test procedures, and validation steps specified in this section for base E2AP functionality. + +This testcase is mandatory if the DUT (Near-RT RIC) claims to support E2AP RIC Control procedure. + +###### 5.2.2.5.1.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Control procedure. +- 3) The RAN Function are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node), see clause 5.2.2.1.1. + +##### 5.2.2.5.1.3 Test Methodology + +###### 5.2.2.5.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the Test Simulator (E2 Node) with the agreed RAN Function been added. + +###### 5.2.2.5.1.3.2 Procedure + +Step 1. Initiate appropriate actions in DUT (Near-RT RIC) to trigger RIC Control procedure to the agreed RAN Function. + +Step 2. At the Test Simulator the received and transmitted E2 messages are recorded. + +Step 3. Received RIC CONTROL REQUEST message defined in [2] clause 9.1.1.8 is validated for the following E2AP information elements defined. + +**Table 5.2.2.5.1-1 Validation for RIC CONTROL REQUEST message** + +| IE/Group Name | Reference | Presence | Validation | +|-------------------------|------------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RIC CONTROL REQUEST | +| RIC Request ID | [2] 9.2.7 | M | Valid RIC Request ID | +| RAN Function ID | [2] 9.2.8 | M | Same as the RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Call Process ID | [2] 9.2.18 | O | Not applicable.<br>This IE shall only be used when RIC CONTROL message is in response to RIC Subscription with RIC Action Type IE as "Insert" | +| RIC Control Header | [2] 9.2.20 | M | IEs defined in RAN Function specific E2 Service Model [4] [5] [6] | +| RIC Control Message | [2] 9.2.19 | M | IEs defined in RAN Function specific E2 Service Model [4] [5] [6] | +| RIC Control Ack Request | [2] 9.2.21 | O | Ack | + +Step 4. If validation in step 3 is successful RIC CONTROL ACKNOWLEDGE message specified in [2] clause 9.1.1.9 is sent to the DUT (Near-RT RIC) with parameters shown in table below. + +**Table 5.2.2.5.1-2 Parameters in RIC CONTROL ACKNOWLEDGE message** + +| IE/Group Name | Reference | Semantics description | +|---------------------|------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC CONTROL ACKNOWLEDGE | +| RIC Request ID | [2] 9.2.7 | Received RIC Request ID in RIC CONTROL REQUEST | +| RAN Function ID | [2] 9.2.8 | Same as the RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Call process ID | [2] 9.2.18 | Not applicable.<br>This IE shall only be used when RIC CONTROL REQUEST message is in response to RIC Subscription with RIC Action Type IE as "Insert" | +| RIC Control Outcome | [2] 9.2.25 | Not used | + +###### 5.2.2.5.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 is successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] clause 8.2.4.2. + +### 5.2.3 E2AP Functional Procedures for E2SM-KPM + +#### 5.2.3.1 Test Cases for RIC Subscription E2SM-KPM + +##### 5.2.3.1.1 RIC Subscription procedure with REPORT Service Style 1, Single Action Format Type 1 (positive) + +###### 5.2.3.1.1.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription procedure to RAN function “O-RAN-E2SM-KPM” Report Style 1 as specified in [5] clause 7.4.1 The expected outcome is successful RIC Subscription by Near-RT RIC. + +This testcase is conditional mandatory if the DUT claims to support RIC Subscription procedure for RAN function “O-RAN-E2SM-KPM” Report Style 1 and Action Format Type 1. + +###### 5.2.3.1.1.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Subscription procedure. +- 3) The RAN Function to which RIC subscribes and the RAN Function definition are predefined between the DUT (Near RT RIC) and the Test Simulator (E2 Node). The agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 is shown in table below. + +**Table 5.2.3.1.1-1 E2SM KPM Function Definition Profile IE profile** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|----------------------------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 1 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement | +| > RIC Report Action Format Type | [5] 8.3.5 | 1 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +- 4) DUT (Near-RT RIC) has functionality to trigger subscription to RAN function “O-RAN-E2SM-KPM” Report Style 1, for the agreed measurement information. + +###### 5.2.3.1.1.3 Test Methodology + +###### 5.2.3.1.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup Request initiated from the Test Simulator (E2 Node) with the agreed RAN Function Definition IE defined in [5] clause 8.2.2.1. + +###### 5.2.3.1.1.3.2 Procedure + +Step 1. The procedures and validations for E2AP specified in Steps 1 to 3 of clause 5.2.2.1.1.3.2 applies with agreed RAN Function Definition IE defined in clause 5.2.3.1.1.2. + +Step 2. E2SM-KPM information elements in RIC SUBSCRIPTION REQUEST message are validated as per table below. + +**Table 5.2.3.1.1-2 Validation for E2SM-KPM IEs in RIC SUBSCRIPTION REQUEST message** + +| E2SM-KPM IE/Group Name | Reference | Validation | +|-----------------------------------------------|---------------|----------------------------------------------| +| RIC Action Definition IE | [5] 8.2.1.2 | | +| >RIC Style Type | [5] 8.2.1.2 | 1 | +| >> E2SM-KPM Action Definition Format1 | [5] 8.2.1.2.1 | | +| >>> Measurement Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >>> Measurement ID | [5] 8.3.10 | Valid ID | +| >>Label Information | [5] 8.3.11 | No Label | +| >>Granularity Period | [5] 8.3.8 | (1..4294967295) | +| RIC Event Trigger Definition IE | [5] 8.2.1.1 | | +| >> E2SM-KPM Event Trigger Definition Format 1 | [5] 8.2.1.1.1 | | +| >> Reporting Period | [5] 8.2.1.1.1 | (1..4294967295) | + +Step 3. If validation in Step 1 and Step 2 are successful RIC SUBSCRIPTION RESPONSE is sent as per clause 5.2.2.1.1.3.2, Step 4. + +###### 5.2.3.1.1.3.3 Expected results + +The same expected results specified in clause 5.2.2.1.1.3.3 applies with the additional validation in step 2 above. + +##### 5.2.3.1.2 RIC Subscription procedure with REPORT Service Style 2, Single Action Format Type 2 (positive) + +###### 5.2.3.1.2.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription procedure with RAN function “O-RAN-E2SM-KPM” Report Style 2 as specified in [5] clause 7.4.3. The expected outcome is successful RIC Subscription by Near-RT RIC. + +This testcase is conditional mandatory if the DUT claims to support RIC Subscription procedure for RAN function “O-RAN-E2SM-KPM” Report Style 2. + +###### 5.2.3.1.2.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Subscription procedure. +- 3) The RAN Function to which RIC subscribes and the RAN Function definition are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). The agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 is shown in table below. + +**Table 5.2.3.1.2-1 E2SM KPM Function Definition IE profile** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|----------------------------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 2 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement for a single UE | +| > RIC Report Action Format Type | [5] 8.3.5 | 2 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +- 4) DUT (Near-RT RIC) has functionality to trigger subscription to RAN function “O-RAN-E2SM-KPM” Report Style 2, for the agreed measurement information. + +###### 5.2.3.1.2.3 Test Methodology + +###### 5.2.3.1.2.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup Request initiated from the Test Simulator (E2 Node) with the agreed RAN Function Definition IE defined in [5] clause 8.2.2.1. + +###### 5.2.3.1.2.3.2 Procedure + +Step 1. The procedures and validations for E2AP specified in Steps 1 to 3 of clause 5.2.2.1.1.3.2 applies with agreed RAN Function Definition IE defined in clause 5.2.3.1.1.2. + +Step 2. E2SM-KPM information elements in RIC SUBSCRIPTION REQUEST message are validated as per table + +**Table 5.2.3.1.2-2 Validation for E2SM-KPM IEs in RIC SUBSCRIPTION REQUEST message** + +| E2SM-KPM IE/Group Name | Reference | Validation | +|----------------------------------------------|---------------|---------------------------------------------------| +| RIC Action Definition IE | [5] 8.2.1.2 | | +| >RIC Style Type | [5] 8.2.1.2 | | +| >> E2SM-KPM Action Definition Format2 | [5] 8.2.1.2.2 | | +| >>>UE ID | [5] 8.3.24 | Valid UE ID pointing to a specific UE of interest | +| >>>> Measurement Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >>>>> Measurement ID | [5] 8.3.10 | (1.. 65535) | +| >>>>> Label Information | [5] 8.3.11 | No Label | +| >>>> Granularity Period | [5] 8.3.8 | Use the same value as Reporting Period | +| >>>> Cell Global ID | [5] 8.3.20 | Not used | +| RIC Event Trigger Definition IE | [5] 8.2.1.1 | | +| > E2SM-KPM Event Trigger Definition Format 1 | [5] 8.2.1.1.1 | | +| >> Reporting Period | [5] 8.2.1.1.1 | (1..4294967295) | + +Step 3. If validation in Step 1 and Step 2 are successful RIC SUBSCRIPTION RESPONSE is sent to DUT (Near-RT RIC) as per clause 5.2.2.1.1.3.2, Step 4. + +###### 5.2.3.1.2.3.3 Expected results + +The same expected results specified in clause 5.2.2.1.1.3.3 applies with the additional validation in 5.2.3.1.2.3.2 Step 2. + +##### 5.2.3.1.3 RIC Subscription procedure with REPORT Service Style 1, Single Action Format Type 1 (negative) + +###### 5.2.3.1.3.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription procedure to RAN function “O-RAN-E2SM-KPM” Report Style 1 as specified in [5] clause 7.4.1 The expected outcome is that Near-RT RIC can receive and process unsuccessful RIC Subscription from E2 node. + +This testcase is conditional mandatory if the DUT claims to support unsuccessful operation of RIC Subscription procedure for RAN function “O-RAN-E2SM-KPM” Report Style 1 and Action Format Type 1. + +###### 5.2.3.1.3.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Subscription procedure. +- 3) The RAN Function to which the DUT (Near RT RIC) subscribes and the RAN Function definition are predefined between the DUT (Near RT RIC) and the Test Simulator (E2 Node). The agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 is shown in table below. + +**Table 5.2.3.1.3-1 E2SM KPM Function Definition Profile IE profile** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|------------|----------------------------------------------------------------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 1 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement | +| > RIC Report Action Format Type | [5] 8.3.5 | 1 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >> Measurement Type ID | [5] 8.3.10 | Optional IE; Test Simulator may configure this IE with one Measurement Type Name | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +- 4) DUT (Near-RT RIC) has functionality to trigger subscription to RAN function “O-RAN-E2SM-KPM” Report Style 1, for the agreed measurement information. + +###### 5.2.3.1.3.3 Test Methodology + +###### 5.2.3.1.3.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface(SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup Request initiated from the Test Simulator (E2 Node) with the agreed RAN Function Definition IE defined in [5] clause 8.2.2.1. + +###### 5.2.3.1.3.3.2 Procedure + +Step 1. The procedures and validations for E2AP specified in Steps 1 to 3 of clause 5.2.2.1.1.3.2 applies with agreed RAN Function Definition IE defined in clause 5.2.3.1.3.2. + +Step 2. E2SM-KPM information elements in RIC SUBSCRIPTION REQUEST message are validated as per table below. + +**Table 5.2.3.1.3-2 Validation for E2SM-KPM IEs in RIC SUBSCRIPTION REQUEST message** + +| E2SM-KPM IE/Group Name | Reference | Validation | +|-----------------------------------------------|---------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| RIC Action Definition IE | [5] 8.2.1.2 | | +| >RIC Style Type | [5] 8.2.1.2 | 1 | +| >> E2SM-KPM Action Definition Format1 | [5] 8.2.1.2.1 | | +| >>>CHOICE <i>Measurement Type</i> | | Select one item of the two parameters below to subscribe if “Measurement ID” is configured during E2 Setup procedure; Otherwise configure “Measurement Name” below. | +| >>>> Measurement Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >>>>Measurement ID | [5] 8.3.10 | The parameter may be configured during E2 Setup Procedure. | +| >>>>Label Information | [5] 8.3.11 | If "Measurement Type Name" is a cell level parameter, the value is set to "No Label";<br>If "Measurement Type Name" is a slice level parameter, the value is set to "Slice ID". | +| >>>>Granularity Period | [5] 8.3.8 | (1.4294967295) | +| >>>> Cell Global ID | [5] 8.3.20 | Mandatory present if the subscribed Measurement above points to a specific cell. | +| RIC Event Trigger Definition IE | [5] 8.2.1.1 | | +| >> E2SM-KPM Event Trigger Definition Format 1 | [5] 8.2.1.1.1 | | +| >>>Reporting Period | [5] 8.2.1.1.1 | (1.4294967295) | + +Step 3. Upon receiving RIC SUBSCRIPTION REQUEST, Test Simulator (E2 Node) shall send RIC SUBSCRIPTION FAILURE with parameters shown in table below. + +**Table 5.2.3.1.3-3 IEs in RIC SUBSCRIPTION FAILURE message** + +| IE/Group Name | Reference | Value | +|-------------------------|-----------|-----------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION RESPONSE | +| RIC Request ID | [2] 9.2.7 | Same RIC Request ID in RIC SUBSCRIPTION REQUEST | +| RAN Function ID | [2] 9.2.8 | Same RAN Function ID in RIC SUBSCRIPTION REQUEST | +| Cause | [2] 9.2.1 | DUT responds Failure with reasonable cause, eg. RIC services->RIC Request->Function resource limit. | +| Criticality Diagnostics | [2] 9.2.2 | | + +###### 5.2.3.1.3.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 2 is successful. +- 2) The DUT could receive the RIC SUBSCRIPTION FAILURE message sent by E2 Node successfully and decode the IEs in Table 5.2.3.1.3-3. DUT doesn't initiate Error Indication procedure after receiving the RIC SUBSCRIPTION FAILURE message. +- 3) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] clause 8.2.1.3. + +##### 5.2.3.1.4 RIC Subscription procedure with REPORT Service Style 2, Single Action Format Type 2 (negative) + +###### 5.2.3.1.4.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription procedure to RAN function "O-RAN-E2SM-KPM" Report Style 1 as specified in [5] clause 7.4.1 The expected outcome is that Near-RT RIC can receive and process unsuccessful RIC Subscription from E2 node. + +This testcase is conditional mandatory if the DUT claims to support unsuccessful operation of RIC Subscription procedure for RAN function "O-RAN-E2SM-KPM" Report Style 2 and Action Format Type 2. + +###### 5.2.3.1.4.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Subscription procedure. +- 3) The RAN Function to which the DUT (Near RT RIC) subscribes and the RAN Function definition are predefined between the DUT (Near RT RIC) and the Test Simulator (E2 Node). The agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 is shown in table below. + +**Table 5.2.3.1.4-1 E2SM KPM Function Definition Profile IE profile** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|------------|----------------------------------------------------------------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 2 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement for a single UE | +| > RIC Report Action Format Type | [5] 8.3.5 | 2 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >> Measurement Type ID | [5] 8.3.10 | Optional IE; Test Simulator may configure this IE with one Measurement Type Name | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +- 4) DUT (Near-RT RIC) has functionality to trigger subscription to RAN function “O-RAN-E2SM-KPM” Report Style 2, for the agreed measurement information. + +##### 5.2.3.1.4.3 Test Methodology + +###### 5.2.3.1.4.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface(SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup Request initiated from the Test Simulator (E2 Node) with the agreed RAN Function Definition IE defined in [5] clause 8.2.2.1. + +##### 5.2.3.1.4.3.2 Procedure + +Step 1. The procedures and validations for E2AP specified in Steps 1 to 3 of clause 5.2.2.1.1.3.2 applies with agreed RAN Function Definition IE defined in clause 5.2.3.1.4.2. + +Step 2. E2SM-KPM information elements in RIC SUBSCRIPTION REQUEST message are validated as per table below. + +**Table 5.2.3.1.4-2 Validation for E2SM-KPM IEs in RIC SUBSCRIPTION REQUEST message** + +| E2SM-KPM IE/Group Name | Reference | Validation | +|----------------------------------------------|---------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| RIC Action Definition IE | [5] 8.2.1.2 | | +| >RIC Style Type | [5] 8.2.1.2 | | +| >> E2SM-KPM Action Definition Format2 | [5] 8.2.1.2.2 | | +| >>>UE ID | [5] 8.3.24 | Valid UE ID pointing to a specific UE of interest | +| >>>CHOICE <i>Measurement Type</i> | | Select one item of the two parameters below to subscribe if “Measurement ID” is configured during E2 Setup procedure; Otherwise configure “Measurement Name” below. | +| >>>> Measurement Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >>>> Measurement ID | [5] 8.3.10 | The parameter may be configured during E2 Setup Procedure. | +| >>>> Label Information | [5] 8.3.11 | If "Measurement Type Name" is a UE level parameter, Value is set to "No Label"; If "Measurement Type Name" is a 5QI level parameter, the value is set to "5QI". | +| >>>> Granularity Period | [5] 8.3.8 | Use the same value as Reporting Period | +| >>>> Cell Global ID | [5] 8.3.20 | The cell which the subscribed UE belongs to | +| RIC Event Trigger Definition IE | [5] 8.2.1.1 | | +| > E2SM-KPM Event Trigger Definition Format 1 | [5] 8.2.1.1.1 | | +| >> Reporting Period | [5] 8.2.1.1.1 | (1..4294967295) | + +Step 3. Upon receiving RIC SUBSCRIPTION REQUEST, Test Simulator (E2 Node) shall send RIC SUBSCRIPTION FAILURE with parameters shown in table below. + +**Table 5.2.3.1.4-3 IEs in RIC SUBSCRIPTION FAILURE message** + +| IE/Group Name | Reference | Value | +|-------------------------|-----------|-----------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION RESPONSE | +| RIC Request ID | [2] 9.2.7 | Same RIC Request ID in RIC SUBSCRIPTION REQUEST | +| RAN Function ID | [2] 9.2.8 | Same RAN Function ID in RIC SUBSCRIPTION REQUEST | +| Cause | [2] 9.2.1 | DUT responds Failure with reasonable cause, eg. RIC services->RIC Request->Function resource limit. | +| Criticality Diagnostics | [2] 9.2.2 | | + +### 5.2.3.1.4.3.3 Expected results + +The test is considered passed if + +1) Validation in test procedure step 2 is successful. + +2) The DUT could receive the RIC SUBSCRIPTION FAILURE message sent by E2 Node successfully and decode the IEs in Table 5.2.3.1.4-3. DUT doesn't initiate Error Indication procedure after receiving the RIC SUBSCRIPTION FAILURE message. + +3) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] clause 8.2.1.3. + +### 5.2.3.1.5 RIC Subscription procedure with REPORT Service Style 1, Single Action Format Type 1 for multiple measurements (positive) + +#### 5.2.3.1.5.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription procedure with multiple KPM measurement items to RAN function “O-RAN-E2SM-KPM” Report Style 1 as specified in [5] clause 7.4.1. The expected outcome is successful RIC Subscription by Near-RT RIC. + +This testcase is conditional mandatory if the DUT claims to support RIC Subscription procedure for RAN function “O-RAN-E2SM-KPM” Report Style 1 and Action Format Type 1. + +### 5.2.3.1.5.2 Test Entrance Criteria + +- 3) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 4) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Subscription procedure. +- 5) The RAN Function to which RIC subscribes and the RAN Function definition are predefined between the DUT (Near RT RIC) and the Test Simulator (E2 Node). The agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 is shown in table below. + +**Table 5.2.3.1.5-1 E2SM KPM Function Definition Profile IE profile** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|------------------------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 1 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement | +| > RIC Report Action Format Type | [5] 8.3.5 | 1 | +| > Sequence of Measurement Info for Action | | At least 2 items | +| >> Measurement Type Name | [5] 8.3.9 | Name of Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +- 4) DUT (Near-RT RIC) has functionality to trigger subscription to RAN function “O-RAN-E2SM-KPM” Report Style 1, for at least two agreed measurement information. + +### 5.2.3.1.5.3 Test Methodology + +#### 5.2.3.1.5.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup Request initiated from the Test Simulator (E2 Node) with the agreed RAN Function Definition IE defined in [5] clause 8.2.2.1. + +#### 5.2.3.1.5.3.2 Procedure + +- Step 1. Initiate appropriate actions in DUT (Near-RT RIC) to trigger RIC Subscription procedure to the agreed RAN Function. +- Step 2. At the Test Simulator the received and transmitted E2 messages are recorded. +- Step 3. Received RIC SUBSCRIPTION REQUEST message defined in [2] clause 9.1.1.1 is validated for the following E2AP information elements defined. + +**Table 5.2.3.1.5-2 Validation for RIC SUBSCRIPTION REQUEST message** + +| IE/Group Name | Reference | Validation | +|-------------------------------|-------------|---------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.1.1.1 | RIC SUBSCRIPTION REQUEST | +| RIC Request ID | [2] 9.1.1.1 | Valid RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Should be same as RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Subscription Details | | | +| >RIC Event Trigger Definition | [2] 9.2.9 | Validation for IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | +| >Sequence of Actions | | | +| >>RIC Action ID | [2] 9.2.10 | Valid RIC Action ID, INTEGER (0..255) | +| >>RIC Action Type | [2] 9.2.11 | Valid RIC Action Type, ENUMERATED (Insert, Report, Policy, ...) | +| >>RIC Action Definition | [2] 9.2.12 | Validation for IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | + +Step 4. E2SM-KPM information elements in RIC SUBSCRIPTION REQUEST message are validated as per table below. Measurement Information List shall include at least two measurement items. + +**Table 5.2.3.1.5-3 Validation for E2SM-KPM IEs in RIC SUBSCRIPTION REQUEST message** + +| E2SM-KPM IE/Group Name | Reference | Validation | +|-----------------------------------------------|---------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| RIC Action Definition IE | [5] 8.2.1.2 | | +| >RIC Style Type | [5] 8.2.1.2 | 1 | +| >> E2SM-KPM Action Definition Format1 | [5] 8.2.1.2.1 | | +| >> Measurement Information List | | At least 2 items | +| >>> Measurement Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >>> Measurement ID | [5] 8.3.10 | Valid ID | +| >>Label Information | [5] 8.3.11 | If "Measurement Type Name" is a cell level parameter, the value is set to "No Label"; If "Measurement Type Name" is a slice level parameter, the value is set to "Slice ID". | +| >>Granularity Period | [5] 8.3.8 | (1..4294967295) | +| RIC Event Trigger Definition IE | [5] 8.2.1.1 | | +| >> E2SM-KPM Event Trigger Definition Format 1 | [5] 8.2.1.1.1 | | +| >> Reporting Period | [5] 8.2.1.1.1 | (1..4294967295) | + +Step 5. If validation in step 3 and step 4 is successful RIC SUBSCRIPTION RESPONSE message specified in [2] clause 9.2.1.1 is sent to the DUT (Near-RT RIC) with parameters shown in table below. + +**Table 5.2.3.1.5-4 Parameters in RIC SUBSCRIPTION RESPONSE message** + +| IE/Group Name | IE type and reference | Semantics description | +|---------------------------|-----------------------|-------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION RESPONSE | +| RIC Request ID | [2] 9.2.7 | Received RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Received RAN Function ID | +| RIC Actions Admitted List | | | +| >RIC Action ID | [2] 9.2.10 | Received Action ID requested included in <i>RIC Actions Admitted List</i> IE. | + +### 5.2.3.1.5.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 and step 4 is successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] clause 8.2.1.2. + +## 5.2.3.1.6 RIC Subscription procedure with REPORT Service Style 2, Single Action Format Type 2 for multiple measurements (positive) + +### 5.2.3.1.6.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription procedure with multiple KPM measurement items to RAN function “O-RAN-E2SM-KPM” Report Style 2 as specified in [5] clause 7.4.3. The expected outcome is successful RIC Subscription by Near-RT RIC. + +This testcase is conditional mandatory if the DUT claims to support RIC Subscription procedure for RAN function “O-RAN-E2SM-KPM” Report Style 2. + +### 5.2.3.1.6.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Subscription procedure. +- 3) The RAN Function to which RIC subscribes and the RAN Function definition are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). The agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 is shown in table below. + +**Table 5.2.3.1.6-1 E2SM KPM Function Definition IE profile** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|------------------------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 2 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement for a single UE | +| > RIC Report Action Format Type | [5] 8.3.5 | 2 | +| > Sequence of Measurement Info for Action | | At least two items | +| >> Measurement Type Name | [5] 8.3.9 | Name of Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +- 4) DUT (Near-RT RIC) has functionality to trigger subscription to RAN function “O-RAN-E2SM-KPM” Report Style 2, for at least two agreed measurement information. + +### 5.2.3.1.6.3 Test Methodology + +#### 5.2.3.1.6.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup Request initiated from the Test Simulator (E2 Node) with the agreed RAN Function Definition IE defined in [5] clause 8.2.2.1. + +#### 5.2.3.1.6.3.2 Procedure + +Step 1. Initiate appropriate actions in DUT (Near-RT RIC) to trigger RIC Subscription procedure to the agreed RAN Function. + +Step 2. At the Test Simulator the received and transmitted E2 messages are recorded. + +Step 3. Received RIC SUBSCRIPTION REQUEST message defined in [2] clause 9.1.1.1 is validated for the following E2AP information elements defined. + +**Table 5.2.3.1.6-2 Validation for RIC SUBSCRIPTION REQUEST message** + +| IE/Group Name | Reference | Validation | +|-------------------------------|-------------|---------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.1.1.1 | RIC SUBSCRIPTION REQUEST | +| RIC Request ID | [2] 9.1.1.1 | Valid RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Should be same as RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Subscription Details | | | +| >RIC Event Trigger Definition | [2] 9.2.9 | Validation for IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | +| >Sequence of Actions | | | +| >>RIC Action ID | [2] 9.2.10 | Valid RIC Action ID, INTEGER (0..255) | +| >>RIC Action Type | [2] 9.2.11 | Valid RIC Action Type, ENUMERATED (Insert, Report, Policy, ...) | +| >>RIC Action Definition | [2] 9.2.12 | Validation for IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | + +Step 4. E2SM-KPM information elements in RIC SUBSCRIPTION REQUEST message are validated as per table below. Measurement Information List shall include at least two measurement items. + +**Table 5.2.3.1.6-3 Validation for E2SM-KPM IEs in RIC SUBSCRIPTION REQUEST message** + +| E2SM-KPM IE/Group Name | Reference | Validation | +|----------------------------------------------|---------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| RIC Action Definition IE | [5] 8.2.1.2 | | +| >RIC Style Type | [5] 8.2.1.2 | | +| >> E2SM-KPM Action Definition Format2 | [5] 8.2.1.2.2 | | +| >>>UE ID | [5] 8.3.24 | Valid UE ID pointing to a specific UE of interest | +| >>>>Measurement Information List | | At least two items | +| >>>>> Measurement Name | [5] 8.3.9 | Name of Measurement agreed for this test | +| >>>>> Measurement ID | [5] 8.3.10 | (1.. 65535) | +| >>>>> Label Information | [5] 8.3.11 | If "Measurement Type Name" is a UE level parameter, Value is set to "No Label"; If "Measurement Type Name" is a 5QI level parameter, the value is set to "5QI". | +| >>>> Granularity Period | [5] 8.3.8 | Use the same value as Reporting Period | +| >>>> Cell Global ID | [5] 8.3.20 | Not used | +| RIC Event Trigger Definition IE | [5] 8.2.1.1 | | +| > E2SM-KPM Event Trigger Definition Format 1 | [5] 8.2.1.1.1 | | +| >> Reporting Period | [5] 8.2.1.1.1 | (1..4294967295) | + +Step 5. If validation in step 3 and step 4 is successful RIC SUBSCRIPTION RESPONSE message specified in [2] clause 9.2.1.1 is sent to the DUT (Near-RT RIC) with parameters shown in table below. + +**Table 5.2.3.1.6-4 Parameters in RIC SUBSCRIPTION RESPONSE message** + +| IE/Group Name | IE type and reference | Semantics description | +|---------------------------|-----------------------|-------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION RESPONSE | +| RIC Request ID | [2] 9.2.7 | Received RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Received RAN Function ID | +| RIC Actions Admitted List | | | +| >RIC Action ID | [2] 9.2.10 | Received Action ID requested included in <i>RIC Actions Admitted List</i> IE. | + +### 5.2.3.1.6.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 and step 4 is successful. + +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] clause 8.2.1.2. + +### 5.2.3.1.7 RIC Indication procedure for REPORT Service style 1 for multiple measurements (positive) + +#### 5.2.3.1.7.1 Test Purpose + +The purpose of this test case is to test the RIC Indication procedure of Near-RT RIC for RAN function “O-RAN-E2SM-KPM” REPORT Service style 1 as specified in [5] clause 7.4.2. The expected outcome of this test is successful receiving of the RIC INDICATION message associated with the E2SM-KPM REPORT Service style 1 from the E2 Node with multiple measurement items. + +This testcase is conditionally mandatory if the DUT (Near-RT RIC) claims to support RIC Indication procedure for RAN function “O-RAN-E2SM-KPM” REPORT Service style 1. + +#### 5.2.3.1.7.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Subscription procedure. +- 3) The RAN Function to which RIC subscribes and the RAN Function definition are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). An example of the agreed RAN Function Definition IE as per configuration is shown in table below. + +**Table 5.2.3.2.3-1 E2SM KPM RAN Function Definition Profile IE profile for this test** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|----------------------------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 1 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement | +| > RIC Report Action Format Type | [5] 8.3.5 | 1 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +- 4) DUT (Near-RT RIC) has functionality to trigger subscription to the RAN Function agreed. + +#### 5.2.3.1.7.3 Test Methodology + +##### 5.2.3.1.7.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (Near-RT RIC) has already successfully completed E2 Setup Request initiated from the Test Simulator (E2 Node) with the agreed RAN Function. +- 3) at least one successful subscription with at least two measurement items associated with E2SM-KPM REPORT Service style 1 exists. The RIC Event Trigger Definition and RIC Action Definition IEs in the RIC SUBSCRIPTION REQUEST message are defined in table below. + +**Table 5.2.3.2.3-2 E2SM-KPM IEs in RIC SUBSCRIPTION REQUEST message** + +| E2SM-KPM IE/Group Name | Reference | Validation | +|-----------------------------------------------|---------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| RIC Action Definition IE | [5] 8.2.1.2 | | +| >RIC Style Type | [5] 8.2.1.2 | 1 | +| >> E2SM-KPM Action Definition Format1 | [5] 8.2.1.2.1 | | +| >>> Measurement Information List | | At least 2 items | +| >>>> Measurement Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >>>> Measurement ID | [5] 8.3.10 | Valid ID | +| >>>>Label Information | [5] 8.3.11 | If "Measurement Type Name" is a cell level parameter, the value is set to "No Label"; If "Measurement Type Name" is a slice level parameter, the value is set to "Slice ID". | +| >>>>Granularity Period | [5] 8.3.8 | (1..4294967295) | +| RIC Event Trigger Definition IE | [5] 8.2.1.1 | | +| >> E2SM-KPM Event Trigger Definition Format 1 | [5] 8.2.1.1.1 | | +| >>> Reporting Period | [5] 8.2.1.1.1 | (1..4294967295) | + +### 5.2.3.1.7.3.2 Procedure + +Step 1. Test Simulator periodically sends RIC INIDACTION message associated with the subscribed REPORT Service to the DUT (Near-RT RIC) according to the reporting period defined in the RIC Event Trigger Definition. The parameters used in the RIC Indication Header (Format 1) and RIC Indication Message (Format 1) are shown in Table 5.2.3.2.3-3 and Table 5.2.3.2.3-4 respectively. The sent and received E2 messages are recorded. + +**Table 5.2.3.2.3-3 RIC Indication Header IE Profile for this test** + +| IE/Group Name | Reference | Configuration/ Value | +|-----------------------|---------------|----------------------------------------------------------------------------------------------------------------------------------------------| +| Collection Start Time | [5] 8.3.12 | Time stamp encoded in the same format as the first four octets of the 64-bit timestamp format as defined in section 6 of IETF RFC 5905 [13]. | +| File Format Version | [5] 8.2.1.3.1 | Not used | +| Sender Name | [5] 8.2.1.3.1 | Not used | +| Sender Type | [5] 8.2.1.3.1 | Not used | +| Vendor Name | [5] 8.2.1.3.1 | Not used | + +**Table 5.2.3.2.3-4 RIC Indication Message IE Profile for this test** + +| IE/Group Name | Reference | Configuration/ Value | +|---------------------------------|---------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurements Data | | | +| >Measurements Record | | Contains measured values in same order as in the <i>Measurements Information List</i> IE if present, otherwise in the order defined in the subscription identified by the <i>Subscription ID</i> . | +| >>CHOICE <i>Measured Value</i> | | | +| >>>>Integer Value | [5] 8.2.1.4.1 | INTEGER (0..4294967295) | +| >>>>Real Value | [5] 8.2.1.4.1 | REAL | +| >>>>No Value | [5] 8.2.1.4.1 | Not used | +| >Incomplete Flag | [5] 8.2.1.4.1 | No incomplete flag | +| Measurement Information List | | At least two items | +| >CHOICE <i>Measurement Type</i> | | | +| >>Measurement Name | [5] 8.3.9 | Same as the Measurement Name received in the corresponding RIC Subscription procedure | +| >>Measurement ID | [5] 8.3.10 | Not used | +| >List of Labels | | | +| >>>Label Information | [5] 8.3.11 | If "Measurement Type Name" is a cell level parameter, the value is set to "No Label"; If "Measurement Type Name" is a slice level parameter, the value is set to "Slice ID". | +| Granularity Period | [5] 8.3.8 | Not used | + +### 5.2.3.1.7.3.3 Expected results + +The test is considered passed if + +- 1) The DUT (Near-RT RIC) correctly receives the RIC INDICATION message from the Test Simulator. + +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] clause 8.2.3.2. + +### 5.2.3.1.8 RIC Indication procedure for REPORT Service style 2 for multiple measurements (positive) + +#### 5.2.3.1.8.1 Test Purpose + +The purpose of this test case is to test the RIC Indication procedure of Near-RT RIC for RAN function “O-RAN-E2SM-KPM” REPORT Service style 2 as specified in [5] clause 7.4.1 The expected outcome of this test is successful reception of the RIC INDICATION message associated with the E2SM-KPM REPORT Service style 2 from the E2 Node with multiple measurement items. + +This testcase is conditionally mandatory if the DUT (Near-RT RIC) claims to support RIC Indication procedure for RAN function “O-RAN-E2SM-KPM” REPORT Service style 2. + +#### 5.2.3.1.8.2 Test Entrance Criteria + +- 1) The Test Simulator (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (Near-RT RIC) and Test Simulator (E2 Node) support RIC Subscription procedure. +- 3) The RAN Function to which RIC subscribes and the RAN Function definition are predefined between the DUT (Near-RT RIC) and the Test Simulator (E2 Node). An example of the agreed RAN Function Definition IE as per configuration is shown in table below. + +**Table 5.2.3.2.4-1 E2SM KPM RAN Function Definition Profile IE profile for this test** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|----------------------------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 1 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement | +| > RIC Report Action Format Type | [5] 8.3.5 | 1 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +- 4) DUT (Near-RT RIC) has functionality to trigger subscription to the RAN Function agreed. + +#### 5.2.3.1.8.3 Test Methodology + +##### 5.2.3.1.8.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 3) The DUT (Near-RT RIC) has already successfully completed E2 Setup Request initiated from the Test Simulator (E2 Node) with the agreed RAN Function. +- 4) at least one successful subscription with at least two measurement items associated with E2SM-KPM REPORT Service style 2 exists. The RIC Event Trigger Definition and RIC Action Definition IEs in the RIC SUBSCRIPTION REQUEST message are defined in Table below. + +**Table 5.2.3.2.4-2 Validation for E2SM-KPM IEs in RIC SUBSCRIPTION REQUEST message** + +| E2SM-KPM IE/Group Name | Reference | Validation | +|----------------------------------------------|---------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| RIC Action Definition IE | [5] 8.2.1.2 | | +| >RIC Style Type | [5] 8.2.1.2 | | +| >> E2SM-KPM Action Definition Format2 | [5] 8.2.1.2.2 | | +| >>>UE ID | [5] 8.3.24 | Valid UE ID pointing to a specific UE of interest | +| >>>>Measurement Information List | | At least two items | +| >>>>> Measurement Name | [5] 8.3.9 | Name of Measurement agreed for this test | +| >>>>> Measurement ID | [5] 8.3.10 | (1.. 65535) | +| >>>>> Label Information | [5] 8.3.11 | If "Measurement Type Name" is a UE level parameter, Value is set to "No Label"; If "Measurement Type Name" is a 5QI level parameter, the value is set to "5QI". | +| >>>> Granularity Period | [5] 8.3.8 | Use the same value as Reporting Period | +| >>>> Cell Global ID | [5] 8.3.20 | Not used | +| RIC Event Trigger Definition IE | [5] 8.2.1.1 | | +| > E2SM-KPM Event Trigger Definition Format 1 | [5] 8.2.1.1.1 | | +| >> Reporting Period | [5] 8.2.1.1.1 | (1..4294967295) | + +### 5.2.3.1.8.3.2 Procedure + +Step 1. Test Simulator periodically sends RIC INIDACTION message associated with the subscribed REPORT Service to the DUT (Near-RT RIC) according to the reporting period defined in the RIC Event Trigger Definition. The parameters used in the RIC Indication Header (Format 2) and RIC Indication Message (Format 2) are shown in Table 5.2.3.2.4-3 and Table 5.2.3.2.4-4. The sent and received E2 messages are recorded. + +**Table 5.2.3.2.4-3 RIC Indication Header IE Profile [8] for this test message** + +| IE/Group Name | Reference | Configuration/ Value | +|-----------------------|---------------|----------------------------------------------------------------------------------------------------------------------------------------------| +| Collection Start Time | [5] 8.3.12 | Time stamp encoded in the same format as the first four octets of the 64-bit timestamp format as defined in section 6 of IETF RFC 5905 [13]. | +| File Format Version | [5] 8.2.1.3.1 | Not used | +| Sender Name | [5] 8.2.1.3.1 | Not used | +| Sender Type | [5] 8.2.1.3.1 | Not used | +| Vendor Name | [5] 8.2.1.3.1 | Not used | + +**Table 5.2.3.2.4-4 RIC Indication Message IE Profile [8] for this test message** + +| IE/Group Name | Presence | Configuration/ Value | +|-------------------------------------------|---------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurements Data | | | +| >Measurements Record | | Contains measured values in same order as in the <i>Measurements Information Condition UE List</i> IE. | +| >>CHOICE <i>Measured Value</i> | | | +| >>>Integer Value | [5] 8.2.1.4.2 | INTEGER (0..4294967295) | +| >>>Real Value | [5] 8.2.1.4.2 | REAL | +| >>>No Value | [5] 8.2.1.4.2 | Not used | +| >Incomplete Flag | [5] 8.2.1.4.2 | No incomplete flag | +| Measurement Information Condition UE List | | At least two items | +| >CHOICE <i>Measurement Type</i> | | | +| >>Measurement Name | [5] 8.3.9 | Same as the Measurement Name received in the corresponding RIC Subscription procedure | +| >>Measurement ID | [5] 8.3.10 | NULL (not selected) | +| >Matching Condition | | | +| >>CHOICE <i>Condition Type</i> | [5] 8.2.1.4.2 | | +| >>>Label Information | [5] 8.3.11 | If "Measurement Type Name" is a UE level parameter, Value is set to "No Label"; If "Measurement Type Name" is a 5QI level parameter, the value is set to "5QI". | +| >>>Test Information | [5] 8.3.22 | No Test Information | +| >List of matched UE IDs | | | +| >>UE ID | [5] 8.3.24 | Valid UE ID | +| Granularity Period | [5] 8.3.8 | No Granularity Period | + +### 5.2.3.1.8.3.3 Expected results + +The test is considered passed if + +- 1) The DUT (Near-RT RIC) correctly receives the RIC INDICATION message from the Test Simulator. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] clause 8.2.3.2. + +## 5.2.3.2 Test Cases for RIC Indication E2SM-KPM + +### 5.2.3.2.1 RIC Indication procedure with REPORT Service style 1 (positive) + +#### 5.2.3.2.1.1 Test Purpose + +The purpose of this test case is to test the RIC Indication procedure of Near-RT RIC for RAN function “O-RAN-E2SM-KPM” REPORT Service style 1 as specified in [5] clause 7.4.2. The expected outcome of this test is successful receiving of the RIC INDICATION message associated with the E2SM-KPM REPORT Service style 1 from the E2 Node. + +This testcase is conditionally mandatory if the DUT (Near-RT RIC) claims to support RIC Indication procedure for RAN function “O-RAN-E2SM-KPM” REPORT Service style 1. + +#### 5.2.3.2.1.2 Test Entrance Criteria + +The test entrance criteria specified in clause 5.2.2.1.1.2 applies with agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 as per configuration profile shown in Table 5.2.3.1.1-1Table 5.2.2-1 + +#### 5.2.3.2.1.3 Test Methodology + +##### 5.2.3.2.1.3.1 Initial conditions + +The initial conditions specified in clause 5.2.2.1.1.3.1 applies. In addition, at least one successful subscription associated with E2SM-KPM REPORT Service style 1 exists. The RIC Event Trigger Definition and RIC Action Definition IEs in the RIC SUBSCRIPTION REQUEST message are defined in Table 5.2.3.1.1-2 + +### 5.2.3.2.1.3.2 Procedure + +Step 1. Test Simulator periodically sends RIC INIDACTION message associated with the subscribed REPORT Service to the DUT (Near-RT RIC) according to the reporting period defined in the RIC Event Trigger Definition. The parameters used in the RIC Indication Header (Format 1) and RIC Indication Message (Format 1) are shown in Table 5.2.3.2.1-1 and Table 5.2.3.2.1-2 respectively. The sent and received E2 messages are recorded. + +**Table 5.2.3.2.1-1 RIC Indication Header IE Profile for this test** + +| IE/Group Name | Reference | Configuration/ Value | +|-----------------------|---------------|----------------------------------------------------------------------------------------------------------------------------------------------| +| Collection Start Time | [5] 8.3.12 | Time stamp encoded in the same format as the first four octets of the 64-bit timestamp format as defined in section 6 of IETF RFC 5905 [13]. | +| File Format Version | [5] 8.2.1.3.1 | Not used | +| Sender Name | [5] 8.2.1.3.1 | Not used | +| Sender Type | [5] 8.2.1.3.1 | Not used | +| Vendor Name | [5] 8.2.1.3.1 | Not used | + +**Table 5.2.3.2.1-2 RIC Indication Message IE Profile [5] for this test** + +| IE/Group Name | Reference | Configuration/ Value | +|---------------------------------|---------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurements Data | | | +| >Measurements Record | | Contains measured values in same order as in the <i>Measurements Information List</i> IE if present, otherwise in the order defined in the subscription identified by the <i>Subscription ID</i> . | +| >>CHOICE <i>Measured Value</i> | | | +| >>>Integer Value | [5] 8.2.1.4.1 | INTEGER (0..4294967295) | +| >>>Real Value | [5] 8.2.1.4.1 | REAL | +| >>>No Value | [5] 8.2.1.4.1 | Not used | +| >Incomplete Flag | [5] 8.2.1.4.1 | No incomplete flag | +| Measurement Information List | | | +| >CHOICE <i>Measurement Type</i> | | | +| >>Measurement Name | [5] 8.3.9 | Same as the Measurement Name received in the corresponding RIC Subscription procedure | +| >>Measurement ID | [5] 8.3.10 | Not used | +| >List of Labels | | | +| >>Label Information | [5] 8.3.11 | No Label | +| Granularity Period | [5] 8.3.8 | Not used | + +### 5.2.3.2.1.3.3 Expected results + +The same expected results specified in clause 5.2.2.4.1.3.3 applies. + +## 5.2.3.2.2 RIC Indication procedure for REPORT Service style 2 (positive) + +### 5.2.3.2.2.1 Test Purpose + +The purpose of this test case is to test the RIC Indication procedure of Near-RT RIC for RAN function “O-RAN-E2SM-KPM” REPORT Service style 2 as specified in [5] clause 7.4.1 The expected outcome of this test is successful reception of the RIC INDICATION message associated with the E2SM-KPM REPORT Service style 2 from the E2 Node. + +This testcase is conditionally mandatory if the DUT (Near-RT RIC) claims to support RIC Indication procedure for RAN function “O-RAN-E2SM-KPM” REPORT Service style 2. + +### 5.2.3.2.2.2 Test Entrance Criteria + +The test entrance criteria specified in clause 5.2.2.1.1.2 apply with agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 as per configuration shown in Table 5.2.3.1.2-1 + +### 5.2.3.2.2.3 Test Methodology + +#### 5.2.3.2.2.3.1 Initial conditions + +- 1) The initial conditions specified in clause 5.2.2.1.1.3.1 apply. In addition, at least one successful subscription associated with E2SM-KPM REPORT Service style 2 exists. The RIC Event Trigger Definition and RIC Action Definition IEs in the RIC SUBSCRIPTION REQUEST message are defined in Table 5.2.3.1.2-2 + +### 5.2.3.2.2.3.2 Procedure + +Step 1. Test Simulator periodically sends RIC INIDACTION message associated with the subscribed REPORT Service to the DUT (Near-RT RIC) according to the reporting period defined in the RIC Event Trigger Definition. The parameters used in the RIC Indication Header (Format 2) and RIC Indication Message (Format 2) are shown in Table 5.2.3-7 and Table 5.2.3-8. The sent and received E2 messages are recorded. + +**Table 5.2.3.2.2-1 RIC Indication Header IE Profile [8] for this test message** + +| IE/Group Name | Reference | Configuration/ Value | +|-----------------------|---------------|----------------------------------------------------------------------------------------------------------------------------------------------| +| Collection Start Time | [5] 8.3.12 | Time stamp encoded in the same format as the first four octets of the 64-bit timestamp format as defined in section 6 of IETF RFC 5905 [13]. | +| File Format Version | [5] 8.2.1.3.1 | Not used | +| Sender Name | [5] 8.2.1.3.1 | Not used | +| Sender Type | [5] 8.2.1.3.1 | Not used | +| Vendor Name | [5] 8.2.1.3.1 | Not used | + +**Table 5.2.3.2.2-2 RIC Indication Message IE Profile [8] for this test message** + +| IE/Group Name | Presence | Configuration/ Value | +|-------------------------------------------|---------------|--------------------------------------------------------------------------------------------------------| +| Measurements Data | | | +| >Measurements Record | | Contains measured values in same order as in the <i>Measurements Information Condition UE List</i> IE. | +| >>CHOICE <i>Measured Value</i> | | | +| >>>Integer Value | [5] 8.2.1.4.2 | INTEGER (0..4294967295) | +| >>>Real Value | [5] 8.2.1.4.2 | REAL | +| >>>No Value | [5] 8.2.1.4.2 | Not used | +| >Incomplete Flag | [5] 8.2.1.4.2 | No incomplete flag | +| Measurement Information Condition UE List | | | +| >CHOICE <i>Measurement Type</i> | | | +| >>Measurement Name | [5] 8.3.9 | Same as the Measurement Name received in the corresponding RIC Subscription procedure | +| >>Measurement ID | [5] 8.3.10 | NULL (not selected) | +| >Matching Condition | | | +| >>CHOICE <i>Condition Type</i> | [5] 8.2.1.4.2 | | +| >>>Label Information | [5] 8.3.11 | No Label Information | +| >>>Test Information | [5] 8.3.22 | No Test Information | +| >List of matched UE IDs | | | +| >>UE ID | [5] 8.3.24 | Valid UE ID | +| Granularity Period | [5] 8.3.8 | No Granularity Period | + +### 5.2.3.2.2.3.3 Expected results + +The same expected results specified in clause 5.2.2.4.1.3.3 applies. + +## 5.2.4 E2AP Functional Procedures for E2SM-RC + +FFS + +## 5.2.5 E2AP Functional Procedures for E2SM-NI + +### 5.2.5.1 Test Cases for RIC Subscription E2SM-NI + +#### 5.2.5.1.1 RIC Subscription for RIC REPORT Style 1, Single Action, RIC Event Trigger 1 (positive case) + +##### 5.2.5.1.1.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription procedure of the Near-RT RIC as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.1. This test case is for subscription to RAN function “ORAN-E2SM-NI” Report style 1 as specified in [4] clause 7.4.2. The expected outcome is successful RIC Subscription by Near-RT RIC. + +This test case is mandatory if the DUT claims to support RIC Subscription procedure for RAN function “O-RAN-E2SM-NI” Report style 1. + +##### 5.2.5.1.1.2 Test Entrance Criteria + +- 1) The test entrance criteria specified in clause 5.2.2.1.1.2 applies with agreed RAN Function Definition IE defined in [4] clause 8.2.2.1 as per configuration shown in table below. + +**Table 5.2.5.1.1-1 E2SM NI RAN Function Definition Profile IE profile.** + +| IE/Group Name | Reference | Configuration / Value | +|--------------------------------------|------------|--------------------------------------------------| +| RAN Function Name | [4] 8.3.2 | | +| >RAN Function Short Name | [4] 8.3.2 | "ORAN-WG3-NI" | +| >RAN Function Service Model OID | [4] 8.3.2 | "1.3.6.1.4.1.53148.1.2.1" | +| > RAN Function Description | [4] 8.3.2 | "Network Interface" | +| Sequence of Network Interface Types | | | +| >Network Interface Type | [4] 8.3.21 | One Network Interface Type agreed for this test. | +| >Sequence of Event trigger styles | | | +| >>RIC Event Trigger Style Type | [4] 8.3.3 | 1 | +| >>RIC Event Trigger Style Name | [4] 8.3.4 | "Interface Message Event" | +| >>RIC Event Trigger Format Type | [4] 8.3.5 | 1 | +| >Sequence of Report styles | | | +| >>RIC Report Style Type | [4] 8.3.3 | 1 | +| >>RIC Report Style Name | [4] 8.3.4 | "Complete message" | +| >>RIC Report Action Format Type | [4] 8.3.5 | 1 | +| >>RIC Indication Header Format Type | [4] 8.3.5 | 1 | +| >>RIC Indication Message Format Type | [4] 8.3.5 | 1 | + +- 2) DUT (Near-RT RIC) has functionality to trigger subscription to RAN function "ORAN-E2SM-NI, compatible RAN Function Revision, Report Style 1, RIC Report Action Format 1 for the agreed Network Interface Type for this test. + +#### 5.2.5.1.1.3 Test Methodology + +##### 5.2.5.1.1.3.1 Initial Conditions + +- 1) The DUT (Near-RT RIC) has successfully completed E2 Setup procedure with the agreed RAN Function ID +- 2) The DUT (Near-RT RIC) has successfully completed RIC subscription procedure with the agreed RIC request ID. + +##### 5.2.5.1.1.3.2 Procedure + +Step 1. The procedures and validations for E2AP specified in Steps 1 to 3 of clause 5.2.2.1.1.3.2 applies with agreed RAN Function Definition IE defined in clause 5.2.5.1.1.2. + +Step 2. E2SM-NI information elements in RIC SUBSCRIPTION REQUEST message are validated as per table below. + +**Table 5.2.5.1.1-2 Validation for RIC SUBSCRIPTION REQUEST for NI Report Style 1** + +| IE/Group Name | Reference | Validation | +|-------------------------------|---------------|----------------------------------------------------------| +| >RIC Event Trigger Definition | [4] 8.2.1.1.1 | E2SM-NI Event Trigger Definition Format 1 | +| >> Network Interface Type | [4] 8.3.21 | Network Interface Type as indicated during subscription. | + +Step 3. If validation in Step 1 and Step 2 are successful RIC SUBSCRIPTION RESPONSE is send as per clause 5.2.2.1.1.3.2, Step 4. + +##### 5.2.5.1.1.3.3 Expected Results + +The same expected results specified in clause 5.2.2.1.1.3.3 applies with the additional validation in Step 2 above. + +## 6 Test Cases for E2 Nodes + +### 6.1 General + +### 6.2 Conformance Test Cases + +#### 6.2.1 E2AP Global Procedures + +##### 6.2.1.1 Test Cases for E2 Setup procedure + +###### 6.2.1.1.1 E2 Setup + +###### 6.2.1.1.1.1 Test Purpose + +The purpose of this test case is to test the E2 Setup procedure of the DUT (E2 Node) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.1. This test is designed to be agnostic to the E2 Service Model and RAN functions supported by the E2 Node. The expected outcome is successful validation of E2 SETUP REQUEST message from E2 Node and establishment of the signalling connection between E2 Node and Near-RT RIC. + +This testcase is mandatory. + +###### 6.2.1.1.1.2 Test Entrance Criteria + +The DUT (E2 Node) has the functionality to trigger E2 Setup procedure. + +###### 6.2.1.1.1.3 Test Methodology + +###### 6.2.1.1.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. (SCTP initiation procedure has taken place before or is taking place with execution of this test case) + +###### 6.2.1.1.1.3.2 Procedure + +Step 1. Initiate appropriate action in DUT (E2 Node) to trigger E2 Setup procedure. + +Step 2. At the Test Simulator (Near-RT RIC) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is E2 SETUP REQUEST as specified in [2] clause 9.1.2.2 and validated with information elements as specified in table below. + +**Table 6.2.1.1.1-1 Validation of IEs in E2 SETUP REQUEST message** + +| IE/Group Name | Reference | Presence | Validation | +|------------------------------------------------------|------------|----------|-----------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | E2 SETUP REQUEST | +| Transaction ID | [2] 9.2.33 | M | Valid <i>Transaction ID</i> , INTEGER (0...255,...) | +| Global E2 Node ID | [2] 9.2.6 | M | Valid <i>Global E2 Node ID</i> corresponding to claimed E2 Node type and supported modes | +| <b>RAN Functions Added List</b> | | | List of RAN functions in E2 Node | +| >RAN Function Item | | | From 1 to maxofRANfunctionID (256) items | +| >>RAN Function ID | [2] 9.2.8 | M | Valid <i>RAN Function ID</i> , INTEGER (1...4095). 0 is invalid as reserved to Near-RT RIC internal usage | +| >>RAN Function Definition | [2] 9.2.23 | M | Valid <i>RAN Function Definition</i> as defined in the corresponding E2 Service Model [3] | +| >>RAN Function Revision | [2] 9.2.24 | M | Valid <i>RAN Function Revision</i> , INTEGER (0...4095) | +| >>RAN Function OID | [2] 9.2.31 | M | Valid <i>RAN Function OID</i> as specified in the corresponding E2 Service Model [3] | +| <b>E2 Node Component Configuration Addition List</b> | | | List of E2 Node component configuration information | +| >E2 Node Component Configuration Addition Item | | | From 1 to maxofE2nodeComponents (1024) items | +| >>E2 Node Component Interface Type | [2] 9.2.26 | M | Valid <i>E2 Node Component Interface Type</i> , ENUMERATED (ng, xn, e1, f1, w1, s1, x2, ...) | + +| | | | | +|-----------------------------------|------------|---|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | corresponding to the DUT E2 node component type | +| >>E2 Node Component ID | [2] 9.2.32 | O | Optional, if present check for valid information elements | +| >>E2 Node Component Configuration | [2] 9.2.27 | M | Refer to table in [2] clause 9.2.27 with DUT (E2 Node) component type to determine the appropriate 3GPP specification. Validate data structure against this specification | + +Step 4. If validation in step 3 is successful, E2 SETUP RESPONSE message as specified in [2] clause 9.1.2.3 is sent to the DUT (E2 Node) with parameters shown in table below + +**Table 6.2.1.1.1-2 Parameters in E2 SETUP RESPONSE message** + +| IE Name | Reference | Configuration / Value | +|------------------------------------------------------------------|------------|---------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | E2 SETUP RESPONSE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) same as received in E2 SETUP REQUEST | +| Global RIC ID | [2] 9.2.4 | Valid Global RIC ID following parameter in Test Simulator | +| <b>RAN Functions Accepted List</b> | | | +| >RAN Functions ID item | | Accept all valid RAN Functions received in E2 SETUP REQUEST | +| >>RAN Function ID | [2] 9.2.8 | Received RAN Function ID | +| >>RAN Function Revision | [2] 9.2.24 | Received RAN Function Revision | +| <b>E2 Node Component Configuration Addition Acknowledge List</b> | | | +| >E2 Node Component Configuration Addition Acknowledge Item | | Acknowledge all valid Component Configuration Addition received in E2 SETUP REQUEST message | +| >>E2 Node Component Interface Type | [2] 9.2.26 | Received E2 Node Component Interface Type | +| >>E2 Node Component ID | [2] 9.2.32 | Received E2 Node Component ID if any present in the E2 SETUP REQUEST message | +| >>E2 Node Component Configuration Acknowledge | [2] 9.2.28 | Success | + +#### 6.2.1.1.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 is successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] Figure 8.3.1.2-1 + +### 6.2.1.2 Test Cases for RESET procedure + +#### 6.2.1.2.1 Reset procedure (initiated by Near-RT RIC) (positive case) + +##### 6.2.1.2.1.1 Test Purpose + +The purpose of this test case is to test the E2 Reset procedure of the E2 Node initiated by Near-RT RIC as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.2. The expected outcome is successful validation of RESET RESPONSE from E2 Node. + +This testcase is mandatory if the DUT (E2 Node) claims to support Reset procedure. + +##### 6.2.1.2.1.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) and Test Simulator (Near-RT RIC) support Reset procedure. +- 2) The Test Simulator (Near-RT RIC) has the functionality to trigger Reset procedure. + +##### 6.2.1.2.1.3 Test Methodology + +##### 6.2.1.2.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. + +2) The DUT (E2 Node) and Test Simulator (Near-RT RIC) have completed E2 Setup procedure. + +#### 6.2.1.2.1.3.2 Procedure + +Step 1. Initiate the Reset procedure from Test Simulator (Near-RT RIC) to the DUT (E2 Node) by sending RESET REQUEST message as specified in [2] clause 9.1.2.5 with information elements as specified in table below. + +**Table 6.2.1.2.1-1 Information elements in RESET REQUEST message** + +| IE Name | Reference | Configuration / Value | +|----------------|------------|-----------------------| +| Message Type | [2] 9.2.3 | RESET REQUEST | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,..) | +| Cause | [2] 9.2.1 | Any valid cause | + +Step 2. At the Test Simulator (Near-RT RIC) the transmitted and received E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RESET RESPONSE as specified in [2] clause 9.1.2.6 with information elements validated as specified in table below + +**Table 6.2.1.2.1-2 Validation of IEs in RESET RESPONSE message** + +| IE/Group Name | Reference | Presence | Validation | +|-------------------------|------------|----------|-----------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RESET RESPONSE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,..) same as received in RESET REQUEST | +| Criticality Diagnostics | [2] 9.2.2 | O | Optional, if present check for valid information elements | + +#### 6.2.1.2.1.3.3 Expected results + +The test is considered passed if + +1) Validation in test procedure step 3 is successful. + +2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] figure 8.3.2.2-2 + +#### 6.2.1.2.2 Reset procedure (initiated by E2 Node) (positive case) + +##### 6.2.1.2.2.1 Test Purpose + +The purpose of this test case is to test the E2 Reset procedure of E2 Node initiated by E2 Node as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.2. The expected outcome is successful validation of RESET REQUEST from E2 Node. + +This testcase is mandatory if the DUT (E2 Node) claims to support Reset procedure. + +##### 6.2.1.2.2.2 Test Entrance Criteria + +1) The DUT (E2 Node) and Test Simulator (Near-RT RIC) support Reset procedure. + +2) The DUT (E2 Node) has the functionality to trigger Reset procedure. + +##### 6.2.1.2.2.3 Test Methodology + +###### 6.2.1.2.2.3.1 Initial conditions + +The initial conditions specified in clause 6.2.1.2.1.3.1 applies. + +###### 6.2.1.2.2.3.2 Procedure + +Step 1. Initiate appropriate action in DUT (E2 Node) to trigger Reset procedure. + +Step 2. At the Test Simulator (Near-RT RIC) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RESET REQUEST as specified in [2] clause 9.1.2.5 and validated with information elements as specified in table below + +**Table 6.2.1.2.2-1 Validation of IEs in RESET REQUEST message** + +| IE/Group Name | Reference | Presence | Validation | +|----------------|------------|----------|-----------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RESET REQUEST | +| Transaction ID | [2] 9.2.33 | M | Valid <i>Transaction ID</i> , INTEGER (0...255,...) | +| Cause | [2] 9.2.1 | M | Valid <i>Cause</i> information element | + +Step 4. If validation in step 3 is successful, RESET RESPONSE message as specified in [2] clause 9.1.2.6 is sent to the DUT (E2 Node) with parameters shown in table below + +**Table 6.2.1.2.2-2 Parameters in RESET RESPONSE message** + +| IE Name | Reference | Configuration / Value | +|-------------------------|------------|---------------------------------------------------------| +| Message Type | [2] 9.2.3 | RESET RESPONSE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) same as received in RESET REQUEST | +| Criticality Diagnostics | [2] 9.2.2 | Optional, not sent | + +### 6.2.1.2.2.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 is successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] figure 8.3.2.2-1 + +## 6.2.1.3 Test Cases for Error Indication + +### 6.2.1.3.1 Error Indication procedure (Transfer Syntax Error) + +#### 6.2.1.3.1.1 Test Purpose + +The purpose of this test case is to test the Error Indication procedure of the DUT (E2-Node) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.3 and clause 10. An ASN.1 syntax error is intentionally made in a message from Test Simulator (Near-RT RIC ) to trigger Error Indication from DUT (E2 Node ). The expected outcome is successful reception and validation of ERROR INDICATION message from E2-Node. + +This testcase is conditional mandatory if DUT claims to support Error Indication procedure. + +#### 6.2.1.3.1.2 Test Entrance Criteria + +The DUT (E2 Node) has the functionality to initiate E2 Setup procedure + +#### 6.2.1.3.1.3 Test Methodology + +##### 6.2.1.3.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). + +##### 6.2.1.3.1.3.2 Procedure + +Step 1. Initiate appropriate action in DUT (E2 Node) to trigger E2 Setup procedure. + +Step 2. At the Test Simulator (Near-RT RIC) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is E2 SETUP REQUEST as specified in [2] clause 9.1.2.2 and validated with information elements as specified in table below. + +**Table 6.2.1.3.1-1 Validation of IEs in E2 SETUP REQUEST message** + +| IE/Group Name | Reference | Presence | Validation | +|------------------------------------------------------|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | E2 SETUP REQUEST | +| Transaction ID | [2] 9.2.33 | M | Valid <i>Transaction ID</i> , INTEGER (0...255,...) | +| Global E2 Node ID | [2] 9.2.6 | M | Valid <i>Global E2 Node ID</i> corresponding to claimed E2 Node type and supported modes | +| <b>RAN Functions Added List</b> | | | List of RAN functions in E2 Node | +| >RAN Function Item | | | From 1 to maxofRANfunctionID (256) items | +| >>RAN Function ID | [2] 9.2.8 | M | Valid <i>RAN Function ID</i> , INTEGER (1...4095). 0 is invalid as reserved to Near-RT RIC internal usage | +| >>RAN Function Definition | [2] 9.2.23 | M | Valid <i>RAN Function Definition</i> as defined in the corresponding E2 Service Model [3] | +| >>RAN Function Revision | [2] 9.2.24 | M | Valid <i>RAN Function Revision</i> , INTEGER (0...4095) | +| >>RAN Function OID | [2] 9.2.31 | M | Valid <i>RAN Function OID</i> as specified in the corresponding E2 Service Model [3] | +| <b>E2 Node Component Configuration Addition List</b> | | | List of E2 Node component configuration information | +| >E2 Node Component Configuration Addition Item | | | From 1 to maxofE2nodeComponents (1024) items | +| >>E2 Node Component Interface Type | [2] 9.2.26 | M | Valid <i>E2 Node Component Interface Type</i> , ENUMERATED (ng, xn, e1, f1, w1, s1, x2, ...) corresponding to the DUT E2 node component type | +| >>E2 Node Component ID | [2] 9.2.32 | O | Optional, if present check for valid information elements | +| >>E2 Node Component Configuration | [2] 9.2.27 | M | Refer to table in [2] clause 9.2.27 with DUT (E2 Node) component type to determine the appropriate 3GPP specification. Validate data structure against this specification | + +Step 4. If validation in step 3 is successful, E2 SETUP RESPONSE message as specified in [2] clause 9.1.2.3 is sent to the DUT (E2 Node) with parameters shown in table below + +**Table 6.2.1.3.1-2 Parameters in E2 SETUP RESPONSE message** + +| IE Name | Reference | Configuration / Value | +|------------------------------------------------------------------|------------|---------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | E2 SETUP RESPONSE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) same as received in E2 SETUP REQUEST | +| Global RIC ID | [2] 9.2.4 | <b>Invalid Global RIC ID eg Near-RT RIC ID more than 20 bit string or invalid PLMN ID</b> | +| <b>RAN Functions Accepted List</b> | | | +| >RAN Functions ID item | | Accept all valid RAN Functions received in E2 SETUP REQUEST | +| >>RAN Function ID | [2] 9.2.8 | Received RAN Function ID | +| >>RAN Function Revision | [2] 9.2.24 | Received RAN Function Revision | +| <b>E2 Node Component Configuration Addition Acknowledge List</b> | | | +| >E2 Node Component Configuration Addition Acknowledge Item | | Acknowledge all valid Component Configuration Addition received in E2 SETUP REQUEST message | +| >>E2 Node Component Interface Type | [2] 9.2.26 | Received E2 Node Component Interface Type | +| >>E2 Node Component ID | [2] 9.2.32 | Received E2 Node Component ID if any present in the E2 SETUP REQUEST message | +| >>E2 Node Component Configuration Acknowledge | [2] 9.2.28 | Success | + +Step 5. The Test Simulator does the following validation: + +The received message from DUT (E2 Node) is ERROR INDICATION message since ASN.1 decoding for Global RIC ID IE should fail at E2 Node. The ERROR INDICATION message is validated with parameters shown in table below. + +**Table 6.2.1.3.1-3 Validation for ERROR INDICATION message** + +| IE Name | Presence | Reference | Configuration / Value | +|-------------------------|----------|------------|------------------------------------------------------------------| +| Message Type | M | [2] 9.2.3 | ERROR INDICATION | +| Transaction ID | O | [2] 9.2.33 | INTEGER (0...255,..) Same as E2 SETUP RESPONSE | +| RIC Request ID | O | [2] 9.2.7 | Required if Transaction ID IE is not present | +| RAN Function ID | O | [2] 9.2.8 | Optional | +| Cause | O | [2] 9.2.1 | Cause Group: Protocol and Protocol Cause : Transfer Syntax Error | +| Criticality Diagnostics | O | [2] 9.2.2 | Optional | + +### 6.2.1.3.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure Step 3 and Step 5 are successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow as specified above. + +## 6.2.1.4 Test Cases for RIC Service Update procedure + +### 6.2.1.4.1 RIC Service Update procedure with empty RIC SERVICE QUERY message (positive case) + +#### 6.2.1.4.1.1 Test Purpose + +The purpose of this test case is to test the RIC Service Update procedure of the DUT (E2 Node) initiated by a RIC SERVICE QUERY message from Test Simulator (Near-RT RIC) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.4. This test case covers the scenario where RIC SERVICE QUERY is sent by Near-RT RIC without *RAN Functions Accepted List IE*. This test is designed to be agnostic to the E2 Service Model and RAN functions supported by the E2 Node. The expected outcome is successful validation of RIC SERVICE UPDATE message from E2 Node. + +This test case is conditional mandatory if DUT claims support of RIC Service Update procedure. + +#### 6.2.1.4.1.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) and Test Simulator support RIC Service Update procedure. +- 2) The Test Simulator (Near-RT RIC) has the functionality to initiate RIC Service Update procedure + +#### 6.2.1.4.1.3 Test Methodology + +##### 6.2.1.4.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The Test Simulator (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the DUT (E2 Node). + +##### 6.2.1.4.1.3.2 Procedure + +Step 1. Initiate the RIC Service Update procedure from Test Simulator (Near-RT RIC) to the DUT (E2 Node) by sending RIC SERVICE QUERY message as specified in [2] clause 9.1.2.10 with information elements as specified in table below without sending *RAN Function Accepted List IE*. + +**Table 6.2.1.4.1-1 Information Elements in RIC SERVICE QUERY message** + +| IE Name | Reference | Configuration / Value | +|----------------|------------|-----------------------| +| Message Type | [2] 9.2.3 | RIC SERVICE QUERY | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,..) | + +Step 2. At the Test Simulator (Near-RT RIC) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RIC SERVICE UPDATE as specified in [2] clause 9.1.2.7 and validated with information elements as specified in table below. + +**Table 6.2.1.4.1-2 Validation of IEs in RIC SERVICE UPDATE message** + +| IE/Group Name | Reference | Presence | Configuration/Value | +|---------------------------------|------------|----------|-----------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RIC SERVICE UPDATE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,...) same as in RIC SERVICE QUERY message | +| <b>RAN Functions Added List</b> | | | List of RAN functions in E2 Node | +| >RAN Function Item | | | From 1 to maxofRANfunctionID (256) items | +| >>RAN Function ID | [2] 9.2.8 | M | Valid <i>RAN Function ID</i> , INTEGER (1...4095). 0 is invalid as reserved to Near-RT RIC internal usage | +| >>RAN Function Definition | [2] 9.2.23 | M | Valid <i>RAN Function Definition</i> as defined in the corresponding E2 Service Model [3] | +| >>RAN Function Revision | [2] 9.2.24 | M | Valid <i>RAN Function Revision</i> , INTEGER (0...4095) | +| >>RAN Function OID | [2] 9.2.31 | M | Valid <i>RAN Function OID</i> as specified in the corresponding E2 Service Model [3] | + +Step 4. If validation in step 3 is successful, RIC SERVICE UPDATE ACKNOWLEDGE message as specified in [2] clause 9.1.2.8 is sent to the DUT (E2 Node) with parameters shown in table below + +**Table 6.2.1.4.1-3 Parameters in RIC SERVICE UPDATE ACKNOWLEDGE message** + +| IE Name | Reference | Configuration / Value | +|------------------------------------|------------|-----------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SERVICE UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) same as received in RIC SERVICE UPDATE message | +| Global RIC ID | [2] 9.2.4 | Valid Global RIC ID following parameter in Test Simulator | +| <b>RAN Functions Accepted List</b> | | | +| >RAN Functions ID item | | Accept all valid RAN Functions received in RIC SERVICE UPDATE message | +| >>RAN Function ID | [2] 9.2.8 | Received RAN Function ID | +| >>RAN Function Revision | [2] 9.2.24 | Received RAN Function Revision | + +#### 6.2.1.4.1.3.3 Expected results + +- 1) Validation in test procedure step 3 is successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] figure 8.3.4.2-1 + +#### 6.2.1.4.2 RIC Service Update procedure with RIC SERVICE QUERY message provided list of Accepted RAN functions (positive case) + +##### 6.2.1.4.2.1 Test Purpose + +The purpose of this test case is to test the RIC Service Update procedure of the DUT (E2 Node) initiated by a RIC SERVICE QUERY message from Test Simulator (Near-RT RIC) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.4. This test case covers the scenario where RIC SERVICE QUERY is sent by Near-RT RIC providing *RAN Functions Accepted List IE*. This test is designed to be agnostic to the E2 Service Model and RAN functions supported by the E2 Node. The expected outcome is successful validation of RIC SERVICE UPDATE message from E2 Node. + +This test case is conditional mandatory if DUT claims support of RIC Service Update procedure. + +##### 6.2.1.4.2.2 Test Entrance Criteria + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The Test Simulator (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the DUT (E2 Node). + +### 6.2.1.4.2.3 Test Methodology + +#### 6.2.1.4.2.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The Test Simulator (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the DUT (E2 Node). +- 3) The Test Simulator (Near-RT RIC) has kept updated in its database the list of RAN Functions supported by the E2 Node and accepted by the Near-RT RIC from E2 Setup and any previous RIC Service Update procedures. + +#### 6.2.1.4.2.3.2 Procedure + +Step 1. Initiate the RIC Service Update procedure from Test Simulator (Near-RT RIC) to the DUT (E2 Node) by sending RIC SERVICE QUERY message as specified in [2] clause 9.1.2.10 with information elements as specified in table below. *RAN Functions Accepted List IE* is the list of RAN Functions supported by the E2 Node and accepted by the Near-RT RIC from E2 Setup and any previous RIC Service Update procedures. + +**Table 6.2.1.4.2-1 Information Elements in RIC SERVICE QUERY message** + +| IE Name | Reference | Configuration / Value | +|------------------------------------|------------|--------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SERVICE QUERY | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) | +| <b>RAN Functions Accepted List</b> | | Updated list of RAN functions from previous procedures | +| >RAN Functions ID Item | | | +| >>RAN Function ID | [2] 9.2.8 | Same as in previous procedures | +| >>RAN Function Revision | [2] 9.2.24 | Same as in previous procedures | + +Step 2. At the Test Simulator (Near-RT RIC) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RIC SERVICE UPDATE as specified in [2] clause 9.1.2.7 and validated with information elements as specified in table below. + +**Table 6.2.1.4.2-2 Validation of IEs in RIC SERVICE UPDATE message** + +| IE/Group Name | Reference | Presence | Configuration/Value | +|------------------------------------|------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RIC SERVICE UPDATE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,...) same as in RIC SERVICE QUERY message | +| <b>RAN Functions Added List</b> | | | List of RAN functions in E2 Node not present in RAN Functions Accepted List IE from RIC SERVICE QUERY message | +| >RAN Function Item | | | From 1 to maxofRANfunctionID (256) items | +| >>RAN Function ID | [2] 9.2.8 | M | Valid <i>RAN Function ID</i> , INTEGER (1...4095). 0 is invalid as reserved to Near-RT RIC internal usage | +| >>RAN Function Definition | [2] 9.2.23 | M | Valid <i>RAN Function Definition</i> as defined in the corresponding E2 Service Model [3] | +| >>RAN Function Revision | [2] 9.2.24 | M | Valid <i>RAN Function Revision</i> , INTEGER (0...4095) | +| >>RAN Function OID | [2] 9.2.31 | M | Valid <i>RAN Function OID</i> as specified in the corresponding E2 Service Model [3] | +| <b>RAN Functions Modified List</b> | | | List of RAN functions in E2 Node present in RAN Functions Accepted List IE from RIC SERVICE QUERY message but with at least one modification | +| >RAN Function Item | | | From 1 to maxofRANfunctionID (256) items | +| >>RAN Function ID | [2] 9.2.8 | M | Valid <i>RAN Function ID</i> , INTEGER (1...4095). same as in RIC SERVICE QUERY message | +| >>RAN Function Definition | [2] 9.2.23 | M | Valid <i>RAN Function Definition</i> as defined in the corresponding E2 Service Model [3] | +| >>RAN Function Revision | [2] 9.2.24 | M | Valid <i>RAN Function Revision</i> , INTEGER (0...4095) | +| >>RAN Function OID | [2] 9.2.31 | M | Valid <i>RAN Function OID</i> as specified in the corresponding E2 Service Model [3] | + +| RAN Functions Deleted List | | | List of RAN functions not supported in E2 Node but present in RAN Functions Accepted List IE from RIC SERVICE QUERY message. | +|----------------------------|------------|---|------------------------------------------------------------------------------------------------------------------------------| +| >RAN Function Item | | | From 1 to maxofRANfunctionID (256) items | +| >>RAN Function ID | [2] 9.2.8 | M | Valid <i>RAN Function ID</i> , INTEGER (1...4095). same as in RIC SERVICE QUERY message | +| >>RAN Function Revision | [2] 9.2.24 | M | Valid <i>RAN Function Revision</i> , INTEGER (0...4095) same as in RIC SERVICE QUERY message | + +Step 4. If validation in step 3 is successful, RIC SERVICE UPDATE ACKNOWLEDGE message as specified in [2] clause 9.1.2.8 is sent to the DUT (E2 Node) with parameters shown in table below + +**Table 6.2.1.4.2-3 Parameters in RIC SERVICE UPDATE ACKNOWLEDGE message** + +| IE Name | Reference | Configuration / Value | +|------------------------------------|------------|--------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SERVICE UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,..) same as received in RIC SERVICE UPDATE message | +| Global RIC ID | [2] 9.2.4 | Valid Global RIC ID following parameter in Test Simulator | +| <b>RAN Functions Accepted List</b> | | | +| >RAN Functions ID item | | Accept all valid RAN Functions received in RIC SERVICE UPDATE message from Added, Modified and Deleted Lists | +| >>RAN Function ID | [2] 9.2.8 | Received RAN Function ID | +| >>RAN Function Revision | [2] 9.2.24 | Received RAN Function Revision | + +#### 6.2.1.4.2.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 is successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] figure 8.3.4.2-1 + +### 6.2.1.5 Test Cases for E2 Node Configuration Update procedure + +#### 6.2.1.5.1 E2 Node Configuration Update procedure after a Near-RT RIC initiated addition of a new TNL association (positive case) + +##### 6.2.1.5.1.1 Test Purpose + +The purpose of this test case is to test the E2 Node Configuration Update procedure of the DUT (E2 Node) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.5 on a newly added TNL association. The expected outcome is successful validation of E2 NODE CONFIGURATION UPDATE message from E2 Node. + +This test case is conditional mandatory if DUT (E2 Node) claims to support E2 Node Configuration Update procedure and multiple TNLAs over E2. + +##### 6.2.1.5.1.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) and Test Simulator support E2 Node Configuration Update, E2 Connection Update procedures and multiple TNLAs over E2. +- 2) The Test Simulator (Near-RT RIC) has the functionality to trigger E2 Connection Update procedure for addition of a new TNL Association. + +### 6.2.1.5.1.3 Test Methodology + +#### 6.2.1.5.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The Test Simulator (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the DUT (E2 Node). + +#### 6.2.1.5.1.3.2 Procedure + +Step 1. Initiate the E2 Connection Update procedure from Test Simulator (Near-RT RIC) to the DUT (E2 Node) by requesting addition of a new TNL Association between DUT and Test Simulator. Validation of the E2 Connection Update procedure is out of the scope of this tests and can be referred in clause 6.2.1.K. + +Step 2. At the Test Simulator (Near-RT RIC) the received, transmitted E2 messages and SCTP Transport level messages are recorded. + +Step 3. The DUT (E2 Node) shall trigger E2 Node Configuration Update procedure on the new TNL Association. + +Step 4. The Test Simulator does the following validation: + +The received message is E2 NODE CONFIGURATION UPDATE as specified in [2] clause 9.1.2.11 and validated with information elements as specified in table below. + +**Table 6.2.1.5.1-1 Validation for E2 NODE CONFIGURATION UPDATE message** + +| IE/Group Name | Reference | Presence | Configuration/Value | +|-------------------|------------|----------------------|--------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | E2 NODE CONFIGURATION UPDATE | +| Transaction ID | [2] 9.2.33 | M | Valid <i>Transaction ID</i> , INTEGER (0...255,...) | +| Global E2 Node ID | [2] 9.2.6 | M (in this scenario) | Valid <i>Global E2 Node ID</i> corresponding to claimed E2 Node type and supported modes. Same as in E2 Setup procedure. | + +Step 5. If validation in step 4 is successful, E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message as specified in [2] clause 9.1.2.12 is sent to DUT (E2 Node) with parameters shown in table below. + +**Table 6.2.1.5.1-2 Parameters in E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message** + +| IE/Group Name | Reference | Configuration/Value | +|----------------|------------|-----------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) same as in E2 NODE CONFIGURATION UPDATE message | + +#### 6.2.1.5.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure Step 4 is successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] figure 8.3.5.2-1 + +### 6.2.1.5.2 E2 Node Configuration Update procedure for E2 Node initiated TNL association removal (positive case) + +#### 6.2.1.5.2.1 Test Purpose + +The purpose of this test case is to test the E2 Node Configuration Update procedure of the DUT (E2 Node) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.5 for removal of a TNL association. The expected outcome is successful validation of E2 NODE CONFIGURATION UPDATE message from E2 Node and removal of the TNL Association. + +This test case is conditional mandatory if DUT (E2 Node) claims to support E2 Node Configuration Update procedure and multiple TNLAs over E2. + +#### 6.2.1.5.2.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) and Test Simulator support E2 Node Configuration Update procedure and multiple TNLAs over E2. +- 2) The DUT (E2 Node) has the functionality to trigger E2 Node Configuration Update procedure for removal of a TNL Association. + +#### 6.2.1.5.2.3 Test Methodology + +##### 5.2.3.1.6.3.4 Initial conditions + +- 1) Two SCTP associations are successfully established between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). +- 2) The Test Simulator (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the DUT (E2 Node) on the first TNL Association. +- 3) The Test Simulator (Near-RT RIC) and DUT (E2 Node) have successfully completed the E2 Node Configuration Update procedure for addition of the second TNL Association, initiated either by the Test Simulator or by the DUT. + +##### 6.2.1.5.2.3.1 Procedure + +Step 1. Initiate appropriate action in the DUT (E2 Node) to trigger E2 Node Configuration Update procedure for removal of the first TNL Association. + +Step 2. At the Test Simulator (Near-RT RIC) the received, transmitted E2 messages and SCTP Transport level messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is E2 NODE CONFIGURATION UPDATE as specified in [2] clause 9.1.2.11 and validated with information elements as specified in table below. + +**Table 6.2.1.5.2-1 Validation for E2 NODE CONFIGURATION UPDATE message** + +| IE/Group Name | Reference | Presence | Configuration/Value | +|-----------------------------------------------|------------|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | E2 NODE CONFIGURATION UPDATE | +| Transaction ID | [2] 9.2.33 | M | Valid <i>Transaction ID</i> , INTEGER (0...255,..) | +| <b>E2 Node TNL Association To Remove List</b> | | | | +| > E2 Node TNL Association To Remove Item IEs | | | | +| >> Transport Layer Information | [2] 9.2.29 | M | Valid <i>Transport Layer Information</i> , BIT STRING for Transport Layer Address (Mandatory, SIZE(1...160,...)) and Transport Layer Port (Optional, SIZE(16) ) Should correspond to the E2 Node Transport Layer Information of the first association | +| >> Transport Layer Information Near-RT RIC | [2] 9.2.29 | O | Optional<br>Valid <i>Transport Layer Information</i> , BIT STRING for Transport Layer Address (Mandatory, SIZE(1...160,...)) and Transport Layer Port (Optional, SIZE(16) ) If provided, should correspond to the Near-RT RIC Transport Layer Information of the first association. | + +Step 4. If validation in step 3 is successful, E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message as specified in [2] clause 9.1.2.12 is sent to DUT (E2 Node) with parameters shown in table below. + +**Table 6.2.1.5.2-2 Parameters in E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message** + +| IE/Group Name | Reference | Configuration/Value | +|---------------|-----------|---------------------| +|---------------|-----------|---------------------| + +| | | | +|----------------|------------|-----------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) same as in E2 NODE CONFIGURATION UPDATE message | + +Step 5. Based on SCTP Transport level messages recorded in Step 2, the Test Simulator validates that the DUT (E2 Node) initiates and performs SCTP connection removal of the first TNL Association, following E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message. + +#### 6.2.1.5.2.3.2 Expected results + +The test is considered passed if + +- 1) Validation in test procedure Step 3 and Step 5 are successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] figure 8.3.5.2-1 + +### 6.2.1.6 Test Cases for E2 Connection Update procedure + +#### 6.2.1.6.1 E2 Connection Update procedure for adding additional TNL Association (positive case) + +##### 6.2.1.6.1.1 Test Purpose + +The purpose of this test case is to test the E2 Connection Update procedure of the DUT (E2 Node) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.6. The expected outcome is successful completion of E2 Connection Update procedure, E2 Node establishing additional TNL Association requested and validation of E2 CONNECTION UPDATE ACKNOWLEDGE message from E2 Node. + +This testcase is conditional mandatory if DUT claims to support E2 Connection Update procedure and multiple TNLAs over E2. + +##### 6.2.1.6.1.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) and Test Simulator support E2 Connection Update procedure and multiple TNLAs over E2. +- 2) The Test Simulator (Near-RT RIC) has the functionality to initiate E2 Connection Update procedure. + +##### 6.2.1.6.1.3 Test Methodology + +###### 6.2.1.6.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The Test Simulator (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the DUT (E2 Node). + +###### 6.2.1.6.1.3.2 Procedure + +Step 1. Initiate the E2 Connection Update procedure from Test Simulator (Near-RT RIC) to the DUT (E2 Node) by sending E2 CONNECTION UPDATE message as specified in [2] clause 9.1.2.14 with information elements as specified in table below. + +**Table 6.2.1.6.1-1 Parameters in E2 CONNECTION UPDATE message** + +| IE Name | Reference | Configuration / Value | +|----------------------------------|------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | E2 CONNECTION UPDATE | +| Transaction ID | [2] 9.2.33 | INTEGER (0...255,...) | +| <b>E2 Connection To Add List</b> | | | +| >E2 Connection to Add Item IEs | | | +| >>Transport Layer Information | [2] 9.2.29 | BIT STRING for Transport Layer Address (Mandatory, SIZE(1...160,...)) and Transport Layer Port (Optional, SIZE(16) )<br>Different from transport layer information used in initial SCTP association | +| >>TNL Association Usage | [2] 9.2.30 | ENUMERATED (ric service, support functions, both,...)<br>“ric service” used as valid example | + +Step 2. At the Test Simulator (Near-RT RIC) the received, transmitted E2 messages and SCTP Transport level messages are recorded. + +Step 3. Based on SCTP Transport level messages recorded in Step 2 validate that the DUT (E2 Node) initiates and establishes a new SCTP connection towards Test Simulator (Near-RT RIC) according to the Transport Layer information (address and port) provided in E2 CONNECTION UPDATE message. + +Step 4. The Test Simulator does the following validation: + +The received message is E2 CONNECTION UPDATE ACKNOWLEDGE as specified in [2] clause 9.1.2.15 and validated for information elements as specified in table below: + +**Table 6.2.1.6.1-2 Validation for E2 CONNECTION UPDATE ACKNOWLEDGE message** + +| IE/Group Name | Reference | Presence | Configuration/Value | +|---------------------------------|------------|----------|---------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | E2 CONNECTION UPDATE ACKNOWLEDGE | +| Transaction ID | [2] 9.2.33 | M | INTEGER (0...255,...) same as in E2 CONNECTION UPDATE message | +| <b>E2 Connection Setup List</b> | | | | +| >E2 Connection Setup Item IEs | | | | +| >>Transport Layer Information | [2] 9.2.29 | M | Same BIT STRING as in E2 CONNECTION UPDATE message | +| >>TNL Association Usage | [2] 9.2.30 | M | “ric service” same as in E2 CONNECTION UPDATE message | + +### 6.2.1.6.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure Step 3 and Step 4 are successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] figure 8.3.5.2-1 + +## 6.2.1.7 Test Cases for E2 Removal Procedure + +### 6.2.1.7.1 E2 Removal procedure initiated by E2 Node (positive case) + +#### 6.2.1.7.1.1 Test Purpose + +The purpose of this test case is to test the E2 Node initiated E2 Removal procedure of E2 Node as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.7. The expected outcome of this test is successful removal of E2 signaling connection between the Near-RT RIC and the E2 Node. + +This testcase is mandatory if the DUT (E2 Node) claims to support E2 Removal procedure. + +#### 6.2.1.7.1.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) and Test Simulator (Near-RT RIC) support E2 Removal procedure. +- 2) The DUT (E2 Node) has the functionality to trigger E2 Removal procedure. + +#### 6.2.1.7.1.3 Test Methodology + +##### 6.2.1.7.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before the execution of this test case). +- 2) The DUT (E2 Node) and Test Simulator has successfully completed E2 Setup procedure. + +##### 6.2.1.7.1.3.2 Procedure + +Step 1. Initiate appropriate action in DUT (E2 Node) to trigger E2 Removal procedure. + +Step 2. At the Test Simulator (Near-RT RIC) the received, transmitted E2 messages and SCTP Transport level messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is E2 REMOVAL REQUEST as specified in [2] clause 9.1.2.17 and validated with information elements as specified in table below: + +**Table 6.2.1.7.1-1 Validation of IEs in REMOVAL REQUEST message** + +| IE/Group Name | Presence | Reference | Configuration / Value | +|----------------|----------|-----------|-----------------------| +| Message Type | M | 9.2.3 | REMOVAL REQUEST | +| Transaction ID | M | 9.2.33 | INTEGER (0..255, ...) | + +Step 4. If validation in step 3 is successful, E2 REMOVAL RESPONSE message as specified in [2] clause 9.1.2.18 is sent to the DUT (E2 Node) with parameters shown in table below + +**Table 6.2.1.7.1-2 Parameters in RESET RESPONSE message** + +| IE/Group Name | Reference | Validation | +|-------------------------|-----------|--------------------------------------------------------------------| +| Message Type | 9.2.3 | | +| Transaction ID | 9.2.33 | INTEGER (0..255, ...)<br>Same value as the one in REMOVAL REQUEST. | +| Criticality Diagnostics | 9.2.2 | Will not be used in this test | + +Step 5. Based on SCTP Transport level messages recorded in Step 2 validate that the DUT (E2 Node) initiates and complete the termination of the SCTP connection by sending the SCTP SHUTDOWN\_COMPLETE message. + +##### 6.2.1.7.1.3.3 Expected results + +- 1) Validations in test procedure Step 4 and Step 5 are successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] figure 8.3.7.2-1 + +#### 6.2.1.7.2 E2 Removal procedure initiated by Near-RT RIC (positive case) + +##### 6.2.1.7.2.1 Test Purpose + +The purpose of this test case is to test the Near-RT initiated E2 Removal procedure of E2 Node as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.3.7. The expected outcome of this test is successful removal of E2 signaling connection between the Near-RT RIC and the E2 Node. + +This testcase is mandatory if the DUT (E2 Node) claims to supports E2 Removal procedure. + +#### 6.2.1.7.2.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) and Test Simulator (Near-RT RIC) support E2 Removal procedure. +- 2) The Test Simulator (Near-RT RIC) has the functionality to trigger E2 Removal procedure. + +#### 6.2.1.7.2.3 Test Methodology + +##### 6.2.1.7.2.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before the execution of this test case). +- 2) The DUT (E2 Node) and Test Simulator (Near-RT RIC) has successfully completed E2 Setup procedure. + +##### 6.2.1.7.2.3.2 Procedure + +Step 1. Initiate the E2 Removal procedure from Test Simulator (Near-RT RIC) to the DUT (E2 Node) by sending E2 REMOVAL REQUEST message as specified in [2] clause 9.1.2.17 with information elements as specified in table below. + +**Table 6.2.1.7.2-1 Parameters in in E2 REMOVAL REQUEST message** + +| IE/Group Name | Reference | Configuration / Value | +|----------------|-----------|-----------------------| +| Message Type | 9.2.3 | REMOVAL REQUEST | +| Transaction ID | 9.2.33 | INTEGER (0..255, ...) | + +Step 2. At the Test Simulator (Near-RT RIC) the transmitted, received E2 messages and SCTP Transport level messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is E2 REMOVAL RESPONSE as specified in [2] clause 9.1.2.18 and validated with information elements as specified in table below: + +**Table 6.2.1.7.2-2 Validation for E2 RESET RESPONSE message** + +| IE/Group Name | Presence | Reference | Validation | +|-------------------------|----------|-----------|-----------------------------------------------------------------| +| Message Type | M | 9.2.3 | | +| Transaction ID | M | 9.2.33 | INTEGER (0..255, ...) Same value as the one in REMOVAL REQUEST. | +| Criticality Diagnostics | O | 9.2.2 | Will not be used in this test | + +Step 4. Based on SCTP Transport level messages recorded in Step 2 validate that the DUT (E2 Node) successfully acknowledge the termination of the SCTP connection initiated by the Test Simulator (Near-RT RIC) and sends SHUTDOWN\_ACK message + +##### 6.2.1.7.2.3.3 Expected results + +- 1) Validation in test procedure step 4 is successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] figure 8.3.7.2-2 + +## 6.2.2 E2AP Functional Procedures + +### 6.2.2.1 Test Cases for RIC Subscription procedure + +#### 6.2.2.1.1 RIC Subscription procedure for single RIC action (positive) + +##### 6.2.2.1.1.1 Test Purpose + +The purpose of this test case is to test RIC Subscription procedure of E2 Node for single RIC action as specified in [2] clause 8.2.1. This test is designed to be agnostic to the E2 Service Model and RAN functions. The RAN Function and RAN Function definition to which RIC subscribes are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). The expected outcome of this test is successful RIC Subscription at E2 Node. + +Test cases for RIC Subscription procedures for specific E2 Service Models and functionalities are defined in sections dedicated for Service Models which will reuse initial conditions, test procedures, and validation steps specified in this section for base E2AP functionality. + +This testcase is mandatory if the DUT claims to support E2AP RIC Subscription procedure. + +. + +##### 6.2.2.1.1.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (E2 Node) and Test Simulator (Near-RT RIC) supports RIC Subscription procedure. +- 3) The Test Simulator (Near-RT RIC) is capable of subscribing to a Service Model and RAN function indicated during the E2 Setup procedure. + +##### 6.2.2.1.1.3 Test Methodology + +###### 6.2.2.1.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +- 2) The Test Simulator (Near-RT RIC) and DUT (E2 Node) have successfully completed E2 Setup procedure using the agreed RAN Function. + +###### 6.2.2.1.1.3.2 Procedure + +Step 1. Initiate appropriate actions in Test Simulator (Near-RT RIC) to trigger RIC Subscription procedure to the DUT (E2 Node) for the agreed RAN Function with the below information elements: + +**Table 6.2.2.1.1-1 Parameters RIC SUBSCRIPTION REQUEST message** + +| IE/Group Name | Reference | Configuration / Value | +|-------------------------------|-------------|----------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.1.1.1 | RIC SUBSCRIPTION REQUEST | +| RIC Request ID | [2] 9.1.1.1 | Any valid RIC Request ID, INTEGER (0.. 65535) | +| RAN Function ID | [2] 9.2.8 | Should be same as RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Subscription Details | | | +| >RIC Event Trigger Definition | [2] 9.2.9 | Use a supported Event Trigger in RAN Function IE in the E2 SETUP REQUEST message exchanged during E2 Setup Procedure | +| >Sequence of Actions | | | +| >>RIC Action ID | [2] 9.2.10 | Any valid RIC Action ID, INTEGER (0..255) | +| >>RIC Action Type | [2] 9.2.11 | Any valid RIC Action Type, ENUMERATED (Insert, Report, Policy, ...) indicated during E2 Setup procedure | +| >>RIC Action Definition | [2] 9.2.12 | Optionally added if required for the Service Model and RAN Function indicated during E2 Setup procedure | +| >>RIC Subsequent Action | [2] 9.2.13 | Optionally added if required for the RIC Action Type, Service Model and RAN Function used. | + +Step 2. At the Test Simulator the received and transmitted E2 messages are recorded. + +Step 3. Received RIC SUBSCRIPTION RESPONSE message defined in [2] clause 9.1.1.2 is validated for the following E2AP information elements defined: + +**Table 6.2.2.1.1-2 Validation for RIC SUBSCRIPTION RESPONSE message** + +| IE/Group Name | IE type and reference | Presence | Validation | +|---------------------------|-----------------------|----------|--------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RIC SUBSCRIPTION RESPONSE | +| RIC Request ID | [2] 9.2.7 | M | RIC Request ID used in RIC SUBSCRIPTION REQUEST | +| RAN Function ID | [2] 9.2.8 | M | RAN Function ID used in RIC SUBSCRIPTION REQUEST | +| RIC Actions Admitted List | | | | +| >RIC Action ID | [2] 9.2.10 | M | RIC Action ID used in RIC SUBSCRIPTION REQUEST | + +### 6.2.2.1.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 is successful. +- 2) E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in [2] clause 8.2.1.2. + +## 6.2.2.2 Test Cases for RIC Subscription Delete procedure + +### 6.2.2.2.1 RIC Subscription Delete procedure (positive) + +#### 6.2.2.2.1.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription Delete procedure of the DUT (E2 Node) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.2. This test is designed to be agnostic to the E2 Service Model and RAN functions. The RAN Function and RAN Function definition to which RIC Subscribes are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). + +The expected outcome of this test is DUT (E2 Node) processing RIC SUBSCRIPTION DELETE REQUEST message successfully and sending the RIC SUBSCRIPTION DELETE RESPONSE. + +This testcase is conditionally mandatory if the DUT claims to support RIC Subscription Delete procedure. + +#### 6.2.2.2.1.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (E2 Node) and Test Simulator (Near-RT RIC) support RIC Subscription Delete procedure. +- 3) The RAN Function the RIC subscribes to and the RAN Function definition are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). An example of the agreed RAN Function Definition IE as per configuration is shown in table below. + +**Table 6.2.2.2.1-1 E2SM KPM RAN Function Definition Profile IE profile for this test** + +| IE Name | Reference | Configuration / Value | +|---------------------------------|-----------|-------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | + +- 4) Near-RT RIC has functionality to trigger RIC subscription delete procedure to E2 Node for agreed RAN Functions. + +#### 6.2.2.2.1.3 Test Methodology + +##### 6.2.2.2.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (E2 Node) has successfully completed E2 Setup procedure and RIC subscription procedure with the agreed RAN Function ID and RIC request ID. + +##### 6.2.2.2.1.3.2 Procedure + +Step 1. Initiate the RIC Subscription Delete procedure from Near-RT RIC to DUT (E2 Node) by sending RIC SUBSCRIPTION DELETE REQUEST message as specified in [2] clause 9.1.1.4 with information elements as specified in table below. + +**Table 6.2.2.2.1-2 Information elements in RIC SUBSCRIPTION DELETE REQUEST message** + +| IE/Group Name | Reference | Configuration / Value | +|-----------------|-----------|--------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION DELETE REQUEST | +| RIC Request ID | [2] 9.2.7 | Use RIC Request ID agreed during RIC Subscription procedure | +| RAN Function ID | [2] 9.2.8 | Use RAN Function ID agreed during RIC Subscription procedure | + +Step 2. At the Test Simulator (Near-RT RIC) the received and transmitted E2 message is recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RIC SUBSCRIPTION DELETE RESPONSE message specified in [2] 9.1.1.5 and validated with information elements as specified in table below. + +**Table 6.2.2.2.1-3 Validation for RIC SUBSCRIPTION DELETE RESPONSE message** + +| IE/Group Name | IE type and reference | Validation | +|-----------------|-----------------------|----------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION DELETE RESPONSE | +| RIC Request ID | [2] 9.2.7 | Received RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Received RAN Function ID | + +Step 4. Validation is done to confirm that RIC SUBSCRIPTION DELETE RESPONSE message has the same RIC Request ID and RAN Function ID as received in RIC SUBSCRIPTION DELETE REQUEST. + +#### 6.2.2.2.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 and step 4 are successful. +- 2) Step 2 E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.2.2 + +#### 6.2.2.2.2 RIC Subscription Delete Request procedure (Negative)-RIC Request ID unknown. + +##### 6.2.2.2.2.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription delete procedure of the DUT (E2 Node) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.2. This test is designed to be agnostic to the E2 Service Model and RAN functions, decided to be used and validates RIC Subscription Delete procedure of E2AP. The RAN Function and RAN Function definition to which RIC Subscribes are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). + +The expected outcome of this test is failure of RIC Subscription deletion due to unsupported RIC request ID. + +This test case is conditionally mandatory if the DUT claims to support RIC Subscription Delete procedure. + +##### 6.2.2.2.2.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (E2 Node) and Test Simulator (Near-RT RIC) support RIC Subscription Delete procedure. +- 3) The RAN Function the RIC subscribes to, and the RAN Function definition are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). An example of the agreed RAN Function Definition IE as per configuration is shown in table below. + +Table 6.2.2.2.2-1 E2SM KPM RAN Function Definition Profile IE profile for this test + +| IE Name | Reference | Configuration / Value | +|---------------------------------|-----------|-------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | + +- 4) Near-RT RIC has functionality to trigger RIC subscription delete to the RAN Function agreed. + +### 6.2.2.2.2.3 Test Methodology + +#### 6.2.2.2.2.3.1 Initial conditions + +- 5) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 6) The DUT (E2 Node) has successfully completed E2 Setup procedure and RIC subscription procedure with agreed RAN function ID and RIC request ID. + +#### 6.2.2.2.2.3.2 Procedure + +Step 1. Initiate the RIC Subscription Delete procedure from Test Simulator (Near-RT RIC) to the DUT (E2 Node) by sending RIC SUBSCRIPTION DELETE REQUEST message as specified in [2] clause 9.1.1.4 with information elements as specified in table below. + +Table 6.2.2.2.2-2 Information elements in RIC SUBSCRIPTION DELETE REQUEST message + +| IE/Group Name | Reference | Validation | +|-----------------|-----------|---------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION DELETE REQUEST | +| RIC Request ID | [2] 9.2.7 | unsupported RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Should be same as RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | + +Step 2. At the Test Simulator (Near-RT RIC) the received and transmitted E2 messages are recorded. + +Step 3. The test simulator does the following validation: + +The received message is RIC SUBSCRIPTION DELETE FAILURE message specified in [2] 9.1.1.6 and validated with information elements as specified in the table below. + +Table 6.2.2.2.2-3 Validation of IEs in RIC SUBSCRIPTION DELETE FAILURE message + +| IE/Group Name | IE type and reference | Validation | +|-----------------|-----------------------|---------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION DELETE FAILURE | +| RIC Request ID | [2] 9.2.7 | Received RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Received RAN Function ID | +| Cause | [2] 9.2.1 | RIC Request ID unknown | + +Step 4. Validation is done to confirm that RIC SUBSCRIPTION DELETE FAILURE message sent with the cause value “RIC Request ID unknown”. + +### 6.2.2.2.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 and step 4 are successful. +- 2) RIC Subscription Delete Failure message sent to Near-RT RIC with the cause value “RIC Request ID unknown”. + +### 6.2.2.2.3 RIC Subscription Delete procedure (Negative)-RAN Function ID invalid. + +#### 6.2.2.2.3.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription delete procedure of the DUT (E2 Node) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.2. This test is designed to be agnostic to the E2 Service Model and RAN functions, decided to be used and validates RIC Subscription Delete procedure of E2AP. The RAN Function and RAN Function definition to which RIC Subscribes are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). + +The expected outcome of this test is failure of RIC Subscription deletion due to unsupported RAN function ID. + +This test case is conditionally mandatory if the DUT claims to support RIC Subscription Delete procedure. + +#### 6.2.2.2.3.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) has the functionality to initiate E2 Setup procedure. +- 2) The DUT (E2 Node) and Test Simulator (Near-RT RIC) support RIC Subscription Delete procedure. +- 3) The RAN Function the RIC subscribes to, and the RAN Function definition are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). An example of the agreed RAN Function Definition IE as per configuration is shown in table below. + +**Table 6.2.2.3-1 E2SM KPM RAN Function Definition Profile IE profile for this test** + +| IE Name | Reference | Configuration / Value | +|---------------------------------|-----------|-------------------------| +| RAN Function Name | [5] 8.3.1 | | +| >RAN Function Short Name | [5] 8.3.1 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.1 | 1.3.6.1.4.1.53148.1.2.2 | +| > RAN Function Description | [5] 8.3.1 | KPM Monitor | + +- 4) Near-RT RIC has functionality to trigger RIC subscription delete to the unsupported RAN Function agreed. + +### 6.2.2.2.3.3 Test Methodology + +#### 6.2.2.2.3.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (E2 Node) has successfully completed E2 Setup procedure and RIC subscription procedure with agreed RAN function ID and RIC request ID. + +#### 6.2.2.2.3.3.2 Procedure + +Step 1. Initiate the RIC Subscription Delete procedure from Test Simulator (Near-RT RIC) to the DUT (E2 Node) by sending RIC SUBSCRIPTION DELETE REQUEST message as specified in [2] clause 9.1.1.4 with information elements as specified in table below. + +**Table 6.2.2.3-2 Information elements in RIC SUBSCRIPTION DELETE REQUEST message** + +| IE/Group Name | Reference | Validation | +|-----------------|-----------|---------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION DELETE REQUEST | +| RIC Request ID | [2] 9.2.7 | Valid RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Should be unsupported RAN Function ID | + +Step 2. At the Test Simulator (Near-RT RIC) the received and transmitted E2 messages are recorded. + +Step 3. The test simulator does the following validation: + +The received message is RIC SUBSCRIPTION DELETE FAILURE message specified in [2] 9.1.1.6 and validated with information elements as specified in table below. + +**Table 6.2.2.2.3-3 Validation of IEs in RIC SUBSCRIPTION DELETE FAILURE message** + +| IE/Group Name | IE type and reference | Validation | +|-----------------|-----------------------|---------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION DELETE FAILURE | +| RIC Request ID | [2] 9.2.7 | Received RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Received RAN Function ID | +| Cause | [2]9.2.1 | RAN Function ID invalid | + +Step 4. Validation is done to confirm that RIC SUBSCRIPTION DELETE FAILURE message sent with the cause value “RAN Function ID invalid”. + +### 6.2.2.2.3.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 and step 4 are successful. +- 2) RIC Subscription Delete Failure message sent to Near-RT RIC with the cause value “RAN Function ID invalid”. + +## 6.2.2.3 Test Cases for RIC Subscription Delete Required procedure + +### 6.2.2.3.1 RIC Subscription Delete Required procedure (positive) + +#### 6.2.2.3.1.1 Test Purpose + +The purpose of this test case is to test the RIC Subscription Delete Required procedure of the DUT (E2 Node) as specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.2A. This test is designed to be agnostic to the E2 Service Model and RAN functions decided to be used. The RAN Function and RAN Function definition to which RIC Subscribes are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). + +The expected outcome of this test is successful validation of RIC SUBSCRIPTION DELETE REQUIRED message. + +This testcase is conditionally mandatory if the DUT (E2 Node) claims to support RIC Subscription Delete Required procedure. + +#### 6.2.2.3.1.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) has the functionality to initiate E2 Setup procedure. + +- 2) The DUT (E2 Node) and Test Simulator (Near-RT RIC) supports RIC Subscription Delete Required procedure. +- 3) The RAN Function the RIC subscribes to, and the RAN Function definition are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). +- 4) DUT (E2 Node) has functionality to trigger RIC Subscription Delete Required procedure. + +### 6.2.2.3.1.3 Test Methodology + +#### 6.2.2.3.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface. +(SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The DUT (E2 Node) has successfully completed E2 Setup procedure and RIC subscription procedure with the agreed RAN Function ID and RIC request ID. + +#### 6.2.2.3.1.3.2 Procedure + +Step 1. Initiate appropriate actions in DUT (E2 Node) to trigger RIC Subscription Delete Required procedure for the agreed RAN Function. + +Step 2. At the Test Simulator the received and transmitted E2 messages are recorded. + +Step 3. Received RIC SUBSCRIPTION DELETE REQUIRED message defined in [2] clause 9.1.1.6A is validated for the following E2AP information elements defined. + +**Table 6.2.2.3.1-1 validation for RIC SUBSCRIPTION DELETE REQUIRED message** + +| IE / Message value | Reference | Configuration / Value | +|-----------------------------------------|-----------|-------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC SUBSCRIPTION DELETE REQUIRED | +| List of RIC Subscriptions to Be Removed | | One item | +| RIC Request ID | [2] 9.2.7 | Should be same as the RIC Request ID used during subscription procedure | +| RAN Function ID | [2] 9.2.8 | Should be same as RAN Function ID used during subscription | +| Cause | [2] 9.2.1 | Any valid cause | + +Step 4. If validation in Step 3 is successful RIC Subscription Delete procedure is initiated by Test Simulator (Near-RT RIC). + +#### 6.2.2.3.1.3.3 Expected results + +The test is considered passed if + +- 1) Validations in test procedure Step 3 is successful. +- 2) Step 2 E2 logs recorded in the Test Simulator (Near-RT RIC) are aligned with the message flow specified in “O-RAN WG3: E2 Application Protocol” [2] clause 8.2.2A.2 + +### 6.2.2.4 Test Cases for RIC Indication procedure + +#### 6.2.2.4.1 RIC Indication procedure for REPORT Service (positive) + +##### 6.2.2.4.1.1 Test Purpose + +The purpose of this test case is to test the RIC Indication procedure of E2 Node as specified in [2] clause 8.2.3. This test is designed to be agnostic to the E2 Service Model and RAN functions. The RAN Function and RAN Function + +definition to which RIC Subscribes are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). The expected outcome of this test is successful validation of the RIC INDICATION message associated with a REPORT Service from the E2 Node. + +Test cases for RIC Indication procedures for specific E2 Service Models and functionalities are defined in sections dedicated for Service Models. These will reuse initial conditions, test procedures, and validation steps specified in this section for base E2AP functionality. + +This testcase is mandatory if the DUT (E2 Node) claims to support E2AP RIC Indication procedure. + +#### 6.2.2.4.1.2 Test Entrance Criteria + +- 1) The DUT (E2 Node) has the functionality to initiate E2 Setup procedure and accept RIC Subscription procedure for REPORT Service. +- 2) The DUT (E2 Node) and Test Simulator (Near-RT RIC) support RIC Indication procedure. +- 3) The RAN Function to which RIC subscribes and the RAN Function definition are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC), see clause 6.2.2.1. +- 4) DUT (E2 Node) has functionality to trigger RIC Indication procedure. + +#### 6.2.2.4.1.3 Test Methodology + +##### 6.2.2.4.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). +- 2) The Test Simulator (Near-RT RIC) has already successfully completed E2 Setup procedure initiated from the DUT (E2 Node) with the agreed RAN Function been added. +- 3) Test Simulator (Near-RT RIC) has already initiated a RIC Subscription procedure to the DUT (E2 Node) and received a successful response with at least one successful action associated with REPORT Service. The RIC Event Trigger Definition and RIC Action Definition IEs specific to E2 Service Models are not defined in the scope of this test. +- 3) + +##### 6.2.2.4.1.3.2 Procedure + +Step 1. Initiate appropriate actions in the DUT (E2 Node) and connected test tools to trigger sending of RIC INDICATION messages to Test Simulator (Near-RT RIC) + +Step 2. At the Test Simulator (Near-RT RIC) the received and transmitted E2 messages are recorded. + +Step 3. The Test Simulator does the following validation: + +The received message is RIC INDICATION message as specified in [2] clause 9.1.1.7 and validated with information elements as specified in table below + +**Table 6.2.2.4.1-1 Validation of IEs in RIC INDICATION message** + +| IE/Group Name | Reference | Presence | Configuration/ Value | +|------------------------|------------|----------|--------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | M | RIC INDICATION | +| RIC Request ID | [2] 9.2.7 | M | Same as the RIC Request ID received in the corresponding RIC subscription procedure | +| RAN Function ID | [2] 9.2.8 | M | Same as the RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Action ID | [2] 9.2.10 | M | Same as the RIC Action ID received in the corresponding RIC subscription procedure | +| RIC Indication SN | [2] 9.2.14 | O | Sequence Number is optional and not validated in this test case | +| RIC Indication Type | [2] 9.2.15 | M | Report | +| RIC Indication Header | [2] 9.2.17 | M | OCTET STRING , this IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | +| RIC Indication Message | [2] 9.2.16 | M | OCTET STRING , this IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | +| RIC Call process ID | [2] 9.2.18 | O | Not applicable.<br>with RIC Action Type IE as "Insert" | + +#### 6.2.2.4.1.3.3 Expected results + +The test is considered passed if validation in step 3 is successful. + +### 6.2.2.5 Test Cases for RIC Control procedure + +#### 6.2.2.5.1 RIC Control procedure for CONTROL Service (positive) + +##### 6.2.2.5.1.1 Test Purpose + +The purpose of this test case is to test the RIC Control procedure of E2 Node as specified in [2] clause 8.2.4. This test is designed to be agnostic to the E2 Service Model and RAN functions. The RAN Function and RAN Function definition to which RIC Subscribes are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC). The expected outcome of this test is successful RIC Control from Near-RT RIC to the E2 Node. + +Test cases for RIC Control procedures for specific E2 Service Models and functionalities are defined in sections dedicated for Service Models. These will reuse initial conditions, test procedures, and validation steps specified in this section for base E2AP functionality. + +This testcase is mandatory if the DUT (E2 Node) claims to support E2AP RIC Control procedure. + +##### 6.2.2.5.1.2 Test Entrance Criteria + +- 4) The DUT (E2 Node) has the functionality to initiate E2 Setup procedure. +- 5) The DUT (E2 Node) and Test Simulator (Near-RT RIC) supports RIC Control procedure. +- 6) The RAN Function are predefined between the DUT (E2 Node) and the Test Simulator (Near-RT RIC), see clause 5.2.2.1. + +##### 6.2.2.5.1.3 Test Methodology + +##### 6.2.2.5.1.3.1 Initial conditions + +- 1) An SCTP association is successfully established between the two SCTP endpoints of the E2 interface (SCTP initiation procedure has taken place before or is taking place with execution of this test case). + +- 2) The Test Simulator (Near-RT RIC) and DUT (E2 Node) have successfully completed E2 Setup procedure using the agreed RAN Function. + +### 6.2.2.5.1.3.2 Procedure + +Step 1. Initiate appropriate actions in Test Simulator (Near-RT RIC) to trigger RIC Control procedure to the DUT (E2 Node) for the agreed RAN Function with the below information elements: + +**Table 6.2.2.5.1-1 Parameters in RIC CONTROL REQUEST message** + +| IE/Group Name | Reference | Semantics description | +|-------------------------|------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC CONTROL REQUEST | +| RIC Request ID | [2] 9.2.7 | Valid RIC Request ID | +| RAN Function ID | [2] 9.2.8 | Same as the RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Call Process ID | [2] 9.2.18 | Not applicable.<br><br>This IE shall only be used when RIC CONTROL REQUEST message is in response to RIC Subscription with RIC Action Type IE as "Insert" | +| RIC Control Header | [2] 9.2.20 | IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | +| RIC Control Message | [2] 9.2.19 | IEs defined in RAN Function specific E2 Service Model [4] [5] [6] is outside the scope of this test. | +| RIC Control Ack Request | [2] 9.2.21 | Ack | + +Step 2. At the Test Simulator the received and transmitted E2 messages are recorded. + +Step 3. Received RIC CONTROL ACKNOWLEDGE message defined in [2] clause 9.1.1.9 is validated for the following E2AP information elements defined. + +**Table 6.2.2.5.1-2 Validation for RIC CONTROL RESPONSE message** + +| IE/Group Name | Reference | Semantics description | +|---------------------|------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | [2] 9.2.3 | RIC CONTROL ACKNOWLEDGE | +| RIC Request ID | [2] 9.2.7 | Received RIC Request ID in RIC CONTROL REQUEST | +| RAN Function ID | [2] 9.2.8 | Same as the RAN Function ID indicated for the agreed RAN Function during E2 Setup procedure | +| RIC Call process ID | [2] 9.2.18 | Not applicable.<br><br>This IE shall only be used when RIC CONTROL REQUEST message is in response to RIC Subscription with RIC Action Type IE as "Insert" | +| RIC Control Outcome | [2] 9.2.25 | Not used | + +### 6.2.2.5.1.3.3 Expected results + +The test is considered passed if + +- 1) Validation in test procedure step 3 is successful. +- 2) E2 logs recorded in the Test Simulator (E2 Node) are aligned with the message flow specified in [2] clause 8.2.4.2. + +## 6.2.3 E2AP Functional Procedures for E2SM-KPM + +FFS + +## 6.2.4 E2AP Functional Procedures for E2SM-RC + +FFS + +## 6.2.5 E2AP Functional Procedures for E2SM-NI + +FFS + +--- + +# 7 Test Cases for Interoperability between Near-RT RIC and E2 Node + +## 7.1 General + +### 7.1.1 Protocol Analyzer and TAP Interface + +A TAP interface and a protocol analyzer may be used over the E2 interface to passively capture and analyze packets for test case validation. Alternatively, packet capture capabilities of the SUT may be used to capture packets for analysis to validate the test cases. Captured packets with associated analysis should be attached to the test report. + +When the following test cases refer to the protocol analyzer and the TAP interface, alternative E2 interface packet capture utilised as long as decoding and analysis have been performed and are available in the test report. + +## 7.2 Interoperability Test Cases + +### 7.2.1 Test Cases for E2AP Global Procedures + +#### 7.2.1.1 Near-RT RIC Support procedures + +##### 7.2.1.1.1 Test Purpose + +The purpose of this test case is to test the interoperability of Near-RT RIC and E2 Node in the E2 interface management and Near-RT RIC support functions as specified in “O-RAN WG3: E2 General Aspects and Principles” [1] clause 5.5 and “O-RAN WG3: E2 Application Protocol” [2] clause 8.3. + +The expected outcome is successful establishment and management of the E2 interface in the SUT. + +This test case is conditional mandatory if the SUT (Near-RT and E2 Node) claims to support E2AP global procedures with the exception of any test steps marked as optional. + +##### 7.2.1.1.2 Test Entrance Criteria + +- 1) Each element of the SUT (Near-RT RIC and E2 Node) supports E2AP global procedures +- 2) (Optional) the Near-RT RIC element of the SUT has the ability to trigger a RIC SERVICE QUERY message (the optional steps 3 can be performed). +- 3) (Optional) one element of the SUT (Near-RT RIC or E2 Node) has the ability to trigger E2 Removal procedure, (the optional step 8 can be performed). + +### 7.2.1.1.3 Test Methodology + +#### 7.2.1.1.3.1 Initial conditions + +- 1) Each element of the SUT (Near-RT RIC and E2 Node) are connected through E2 interface. +- 2) Network between Near-RT RIC and E2 Node allows connectivity between the elements. +- 3) Near-RT RIC and E2 Nodes are configured, through O1 interface or other vendor specific configuration interface, with the needed parameters for the association, in particular the transport layer parameters (Near-RT RIC address configured in E2 Node), RIC Service information and E2 node configuration. +- 4) The status of the SCTP association and E2 setup procedure is in one of the following conditions +condition A: SCTP association has not yet been established. Then E2 Node shall initiate the SCTP procedure during step 2 below. +condition B: SCTP association has been established and configuration of the E2 Node is such that E2 Node is not yet sending any E2 SETUP REQUEST message towards Near-RT RIC. +condition C: SCTP association has been established and E2 Node is sending E2 SETUP REQUEST messages to Near-RT RIC but configuration in Near-RT RIC is such that no E2 SETUP RESPONSE is sent back. + +#### 7.2.1.1.3.2 Procedure + +Step 1. Enable the protocol analyzer to capture, record and decode the E2 signalling between SUT elements via the TAP interface. + +Step 2. Depending on the initial condition 4), enable the E2 interface towards the associated element either in Near-RT RIC or in E2 Node, by configuration or by establishment of the physical connection. + +E2 Node initiates E2 Setup procedure by sending E2 SETUP REQUEST message to the Near-RT RIC + +Near-RT RIC sends E2 SETUP RESPONSE to E2 Node with the list of accepted and rejected RAN Functions + +Step 3. (Optional) If the Near-RT RIC has the ability to trigger RIC SERVICE QUERY message towards the E2 Node, initiate appropriate action to trigger the procedure. + +After reception of RIC SERVICE QUERY message, E2 Node sends RIC SERVICE UPDATE message to the Near-RT RIC. E2 Node may send RIC SERVICE UPDATE message without any IE except for *Message Type* IE as specified in [2] clause 8.3.4.2. + +Near-RT RIC sends RIC SERVICE UPDATE ACKNOWLEDGE message to the E2 Node. + +Step 4. Take appropriate action to initiate on E2 Node one of the following RIC service configuration changes: + +- Adding a new RAN Function +- Modifying an existing RAN Function +- Deleting an existing RAN Function + +Step 5. E2 Node initiates RIC Service Update procedure by sending RIC SERVICE UPDATE message to the Near-RT RIC with the configuration change performed in Step 4. + +Near-RT RIC sends RIC SERVICE UPDATE ACKNOWLEDGE message to the E2 Node. + +Step 6. Take appropriate action to initiate on the E2 Node one of the following E2 Node system configuration changes + +- Adding a new E2 Node Component Configuration +- Updating an existing E2 Node Component Configuration +- Removing an existing E2 Node Component Configuration + +Step 7. E2 Node triggers E2 Node Configuration Update procedure by sending E2 NODE CONFIGURATION UPDATE message to the Near-RT RIC. + +Near-RT RIC sends E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message to the E2 Node. + +Step 8 (Optional) If one element of the SUT (Near-RT RIC or E2 Node) has the ability to trigger E2 Removal procedure, then initiate appropriate action to trigger the procedure. + +- The element of the SUT (Near-RT RIC or E2 Node) initiating the E2 Removal procedure sends E2 REMOVAL REQUEST message. +- The other element sends E2 REMOVAL RESPONSE message to initiating element. +- The initiating element initiates the removal of the TNL associations. + +### 7.2.1.1.3.3 Expected results + +The test is considered passed if + +- 1) All messages are correctly decoded by the protocol analyzer +- 2) E2 logs recorded in the protocol analyzer for steps 1 to 8 above are aligned with successful operation message flows specified in [2] clause 8.3. and coherent with the configuration in E2 Node and Near-RT RIC + +In particular the following procedures should be thoroughly validated: + +E2 Setup procedure (Step 2): RAN Functions and E2 Node Component Configuration configured in E2 Node. are present in E2 SETUP message, and in E2 SETUP RESPONSE message *RAN Functions Accepted List IE* or *RAN Functions Rejected List IE* for RAN Functions and *E2 Node Component Configuration Addition Acknowledge List IE* for E2 Node Component Configurations. + +RIC Service Update procedure (Step 5): RIC SERVICE UPDATE message is aligned with the modification performed in E2 Node configuration in Step 4. And the RAN Functions present in RIC SERVICE UPDATE message are present either in *RAN Functions Accepted List IE* or *RAN Functions Rejected List IE* of RIC SERVICE UPDATE ACKNOWLEDGE message. + +E2 Node Configuration Update procedure (Step 7) E2 NODE CONFIGURATION UPDATE message is aligned the modification performed in E2 Node configuration in Step 6. And the E2 Node Component Configurations present in E2 NODE CONFIGURATION UPDATE message are present in E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message in the corresponding *E2 Node Component Configuration Addition Acknowledge List*, *E2 Node Component Configuration Update Acknowledge List* or *E2 Node Component Configuration Removal Acknowledge List* information elements. + +### 7.2.1.1.3.4 RAN Functions, E2 Node Components Configuration rejection and unexpected behaviors + +If any of the following IEs is observed in the recorded E2 logs: + +- *RAN Functions Rejected List IE* in E2 SETUP RESPONSE message or RIC SERVICE UPDATE ACKNOWLEDGE message +- *E2 Connection Failed to Setup List IE* in E2 CONNECTION UPDATE ACKNOWLEDGE message + +- *Outcome* IE from *E2 Node Component Configuration Acknowledge* IE is *failure* in E2 SETUP RESPONSE message or in E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message +- *Criticality diagnostics* IE in E2 REMOVAL RESPONSE message + +the test result shall be determined to be “successful with remarks”. + +If a RESET procedure has been triggered by one the elements of the SUT, the test result shall determined to be “successful with remarks” + +#### 7.2.1.1.3.5 Unsuccessful operations and Error Indication + +If any of the global procedures completes unsuccessfully or if an Error Indication procedure is triggered by one of the elements of the SUT, then the test result shall be determined as failed. + +## 7.2.2 Test Cases for E2AP Functional Procedures for E2SM-KPM + +### 7.2.2.1 Tests cases for RIC REPORT Service Styles procedures E2SM-KPM + +#### 7.2.2.1.1 RIC Subscription and RIC Indication procedures with REPORT Service Style 1, Single Action Format Type 1, Indication Message Format Type 1 + +##### 7.2.2.1.1.1 Test Purpose + +The purpose of this test case is to test the interoperability of Near-RT RIC and E2 Node in RAN function “O-RAN-E2SM-KPM” Report Service Style 1: E2 Node Measurement, as specified in [5] clause 7.4.2 + +The expected outcome is successful RIC Subscription and RIC Indication procedures by the SUT. + +This test case is conditional mandatory if the SUT (Near-RT and E2 Node) claims to support RAN function “O-RAN-E2SM-KPM” Report Style 1. + +##### 7.2.2.1.1.2 Test Entrance Criteria + +- 4) Each element of the SUT (Near-RT RIC and E2 Node) supports RAN function “O-RAN-E2SM-KPM” Report Style 1, Action Format Type 1, and Indication Message Format Type 1. +- 5) Each element of the SUT (Near-RT RIC and E2 Node) supports RIC Subscription procedure and RIC Indication procedure for the above RAN Function. +- 6) The Test Equipment (RU and UE simulator) has the ability to generate the traffic required for the agreed measurement. +- 7) A reporting period for the measurement is agreed and configured in the SUT. The test duration is then selected to allow to cover several reporting periods. +- 8) The RAN Function to which RIC subscribes and the RAN Function definition are predefined between the elements of the SUT (Near RT RIC and E2 Node). The agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 is shown in table below. + +**Table 7.2.2.1.1-1 E2SM KPM Function Definition Profile IE profile** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|----------------------------------------------| +| RAN Function Name | [5] 8.3.2 | | +| >RAN Function Short Name | [5] 8.3.2 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.2 | 1.3.6.1.4.1.53148.1.1.2.2 | +| > RAN Function Description | [5] 8.3.2 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 1 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement | +| > RIC Report Action Format Type | [5] 8.3.5 | 1 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +1 + +## 2 7.2.2.1.1.3 Test Methodology + +### 3 7.2.2.1.1.3.1 Initial conditions + +4 5) The elements of the SUT (Near-RT RIC and E2 Node) are connected by E2 interface + +5 6) The E2 Setup procedure is successfully completed in the SUT with the agreed RAN Function + +6 Definition IE + +### 7 7.2.2.1.1.3.2 Procedure + +8 Step 1. Enable the protocol analyzer to capture, record and decode the E2 signalling between SUT elements via the +9 TAP interface + +10 Step 2. Initiate in the Test Equipment the traffic required for the agreed measurement + +11 Step 3. Perform RIC Subscription Request from the Near-RT RIC + +12 An example of how this procedure can be performed (or triggered) is listed below. The exact method to perform +13 (or trigger) this procedure is out of scope of this specification and is left up to the implementation of the DUT. + +14 a. Initiate appropriate action or configuration in the SUT to trigger the RIC Subscription Request + +15 Step 4. The Near-RT RIC initiates RIC Subscription procedure by sending RIC SUBSCRIPTION REQUEST +16 message to the E2 Node, with the agreed RAN Function Definition IE and measurement information + +17 The E2 Node sends RIC SUBSCRIPTION RESPONSE to Near-RT RIC with the list of admitted and not admitted +18 RAN Actions + +19 The E2 Node sends periodic REPORT RIC INDICATION messages for the agreed RAN Function Definition with +20 the agreed measurement to the Near-RT RIC + +21 Step 5. The test is ended after the test duration defined in test entrance criteria, allowing the E2 Node to send several +22 RIC INDICATION messages to the Near-RT RIC + +23 + +### 24 7.2.2.1.1.3.3 Expected results + +25 The test is considered passed if + +26 3) All messages are correctly decoded by the protocol analyzer + +27 4) E2 logs recorded in the protocol analyzer are aligned with successful operation message flows + +28 specified in [2] clause 8.2. and consistent with the configuration in E2 Node and Near-RT RIC + +- 5) RIC Subscription procedure is successful and it is validated in recorded E2 logs that + - *RAN Function ID IE* corresponds to the agreed RAN Function (during E2 Setup procedure) in both RIC SUBSCRIPTION REQUEST and RIC SUBSCRIPTION RESPONSE messages + - *RIC REQUEST ID IE* is the same in RIC SUBSCRIPTION REQUEST, RIC SUBSCRIPTION RESPONSE and RIC INDICATION messages + - *RIC Action ID IE* is the same in RIC SUBSCRIPTION REQUEST message, in *RIC Actions Admitted List IE* of RIC SUBSCRIPTION RESPONSE message and in RIC INDICATION message + - *RIC Action Definition IE* in RIC SUBSCRIPTION REQUEST message is E2SM-KPM Action Definition Format 1 with the agreed measurement. +- 6) Periodicity of the RIC INDICATION messages in the recorded E2 logs corresponds with the value of *Reporting Period IE* from *RIC Event Trigger Definition IE* of RIC SUBSCRIPTION REQUEST message as defined in [5] clause 8.2.1.1.1 +- 7) *Measurement Type IE* in the RIC INDICATION messages is the same as that in the RIC SUBSCRIPTION REQUEST message +- 8) Measurements reported by the E2 Node in the RIC Indication messages are consistent with the traffic simulated by the Test Equipment + +If an Error Indication procedure is triggered during the test, then the test result shall be determined as failed. + +If the agreed *RIC Action ID IE* is present in the *RIC Actions Not Admitted List IE* of RIC SUBSCRIPTION RESPONSE message, then the test result shall be determined as failed. + +#### 7.2.2.1.2 RIC Subscription and RIC Indication procedures with REPORT Service Style 2, Single Action Format Type 2, Indication Message Format Type 1 + +##### 7.2.2.1.2.1 Test Purpose + +The purpose of this test case is to test the interoperability of Near-RT RIC and E2 Node in RAN function “O-RAN-E2SM-KPM” Report Service Style 2: E2 Node Measurement for a single UE, as specified in [5] clause 7.4.3 +The expected outcome is successful RIC Subscription and RIC Indication procedures by the SUT. + +This test case is conditional mandatory if the SUT (Near-RT and E2 Node) claims to support RAN function “O-RAN-E2SM-KPM” Report Style 2. + +##### 7.2.2.1.2.2 Test Entrance Criteria + +- 1) Each element of the SUT (Near-RT RIC and E2 Node) supports RAN function “O-RAN-E2SM-KPM” Report Style 2, Action Format Type 2, and Indication Message Format Type 1 +- 2) Each element of the SUT (Near-RT RIC and E2 Node) supports RIC Subscription procedure and RIC Indication procedure for the above RAN Function +- 3) The Test Equipment (RU and UE simulator) has the ability to generate the traffic required for the agreed measurement + +- 4) A reporting period for the measurement is agreed and configured in the SUT. The test duration is then selected to allow to cover several reporting periods +- 5) The RAN Function to which RIC subscribes and the RAN Function definition are predefined and shared between the elements of the SUT (Near RT RIC and E2 Node). The agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 is shown in table below. + +**Table 7.2.2.1.2-1 E2SM KPM Function Definition Profile IE profile** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|----------------------------------------------| +| RAN Function Name | [5] 8.3.2 | | +| >RAN Function Short Name | [5] 8.3.2 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.2 | 1.3.6.1.4.1.53148.1.1.2.2 | +| > RAN Function Description | [5] 8.3.2 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 2 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement for a single UE | +| > RIC Report Action Format Type | [5] 8.3.5 | 2 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +### 7.2.2.1.2.3 Test Methodology + +#### 7.2.2.1.2.3.1 Initial conditions + +- 1) The elements of the SUT (Near-RT RIC and E2 Node) are connected by E2 interface +- 2) E2 Setup procedure is successfully completed in the SUT with the agreed RAN Function Definition IE + +#### 7.2.2.1.2.3.2 Procedure + +Step 1. Enable the protocol analyzer to capture, record and decode the E2 signalling between SUT elements via the TAP interface + +Step 2. Initiate in the Test Equipment the traffic required for the agreed measurement + +Step 3. Perform RIC Subscription Request from the Near-RT RIC. + +An example of how this procedure can be performed (or triggered) is listed below. The exact method to perform (or trigger) this procedure is out of scope of this specification and is left up to the implementation of the DUT. + +- a. Initiate appropriate action or configuration in the SUT to trigger the RIC Subscription Request + +Step 4. The Near-RT RIC initiates the RIC Subscription procedure by sending RIC SUBSCRIPTION REQUEST message to the E2 Node, with the agreed RAN Function Definition IE and measurement information + +The E2 Node sends RIC SUBSCRIPTION RESPONSE to Near-RT RIC with the list of admitted and not admitted RAN Actions + +The E2 Node sends periodic REPORT RIC INDICATION messages for the agreed RAN Function Definition with the agreed measurement to the Near-RT RIC for the requested UE Id + +Step 5. The test is ended after the test duration defined in test entrance criteria, allowing the E2 Node to send several RIC INDICATION messages to the Near-RT RIC + +#### 7.2.2.1.2.3.3 Expected results + +The test is considered passed if + +- 1) All messages are correctly decoded by the protocol analyzer +- 2) E2 logs recorded in the protocol analyzer are aligned with successful operation message flows specified in [2] clause 8.2. and consistent with the configuration in E2 Node and Near-RT RIC +- 3) RIC Subscription procedure is successful and it is validated in recorded E2 logs that + - *RAN Function ID IE* corresponds to the agreed RAN Function (during E2 Setup procedure) in both RIC SUBSCRIPTION REQUEST and RIC SUBSCRIPTION RESPONSE messages + - *RIC REQUEST ID IE* is the same that in the RIC SUBSCRIPTION REQUEST, RIC SUBSCRIPTION RESPONSE and RIC INDICATION messages + - The *RIC Action ID IE* is the same as that in the RIC SUBSCRIPTION REQUEST message in the *RIC Actions Admitted List IE* of the RIC SUBSCRIPTION RESPONSE message and in the RIC INDICATION message + - The *RIC Action Definition IE* in the RIC SUBSCRIPTION REQUEST message indicates E2SM-KPM Action Definition Format 1 with the agreed measurement +- 4) Periodicity of the RIC INDICATION messages in the recorded E2 logs corresponds with the value of *Reporting Period IE* from *RIC Event Trigger Definition IE* of RIC SUBSCRIPTION REQUEST message as defined in [5] clause 8.2.1.1.1 +- 5) *The Measurement Type IE* in the RIC INDICATION messages is the same as that in RIC SUBSCRIPTION REQUEST message +- 6) Measurements reported by E2 Node in the RIC Indication messages are consistent with the traffic simulated by the Test Equipment for the specified UE Id + +If an Error Indication procedure is triggered during the test, then the test result shall be determined as failed. + +If the agreed *RIC Action ID IE* is present in the *RIC Actions Not Admitted List IE* of RIC SUBSCRIPTION RESPONSE message, then the test result shall be determined as failed. + +### 7.2.2.1.3 RIC Subscription and RIC Indication procedures with REPORT Service Style 3, Single Action Format Type 3, Indication Message Format Type 2 + +#### 7.2.2.1.3.1 Test Purpose + +The purpose of this test case is to test the interoperability of Near-RT RIC and E2 Node in RAN function “O-RAN-E2SM-KPM” Report Service Style 3: Condition-based, UE-level E2 Node Measurement, as specified in [5] clause 7.4.4. The expected outcome is successful RIC Subscription and RIC Indication procedures by the SUT. + +This test case is conditional mandatory if the SUT (Near-RT and E2 Node) claims to support RAN function “O-RAN-E2SM-KPM” Report Style 3. + +#### 7.2.2.1.3.2 Test Entrance Criteria + +- 1) Each element of the SUT (Near-RT RIC and E2 Node) supports RAN function “O-RAN-E2SM-KPM” Report Style 3 and Action Format Type 3 and Indication Message Format Type 2 + +- 2) The RAN Function to which RIC subscribes and the RAN Function definition are predefined and shared between the elements of the SUT (Near RT RIC and E2 Node). A Measurement Type as specified in [5] clause 8.3.9 is agreed along with a Matching Condition as specified in [5] clause 8.2.1.2.3. The agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 is shown in table below + +**Table 7.2.2.1.3-1 E2SM KPM Function Definition Profile IE profile** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|----------------------------------------------| +| RAN Function Name | [5] 8.3.2 | | +| >RAN Function Short Name | [5] 8.3.2 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.2 | 1.3.6.1.4.1.53148.1.1.2.2 | +| > RAN Function Description | [5] 8.3.2 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 3 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement for a single UE | +| > RIC Report Action Format Type | [5] 8.3.5 | 3 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 2 | + +- 3) Each element of the SUT (Near-RT RIC and E2 Node) supports RIC Subscription procedure and RIC Indication procedure for the above RAN Function + +- 4) The matching condition is successively matched and unmatched for a given UE. + +An example of how this procedure can be performed (or triggered) is listed below. The exact method to perform (or trigger) this procedure is out of scope of this specification and is left up to the implementation of the DUT. + +- a. The Test Equipment (RU and UE simulator) generates the traffic required for the agreed Measurement in a scenario where the Matching Condition will be successively matched and then unmatched for a given UE + +For simplification in this test a single UE traffic is considered + +- 5) A reporting period for the measurement is agreed and configured in the SUT. + +Note: The test duration is then selected to allow to cover several reporting periods with the traffic scenario both matching and unmatching the agreed condition for the followed UE. + +### 7.2.2.1.3.3 Test Methodology + +#### 7.2.2.1.3.3.1 Initial conditions + +- 1) The elements of the SUT (Near-RT RIC and E2 Node) are connected by E2 interface +- 2) The E2 Setup procedure is successfully completed in the SUT with the agreed RAN Function Definition IE + +#### 7.2.2.1.3.3.2 Procedure + +Step 1. Enable the protocol analyzer to capture, record and decode the E2 signalling between SUT elements via the TAP interface + +Step 2. Initiate in the Test Equipment the traffic required for the agreed measurement with the agreed condition being matched. + +Step 3. Perform the RIC Subscription Request from the Near-RT RIC + +An example of how this procedure can be performed (or triggered) is listed below. The exact method to perform (or trigger) this procedure is out of scope of this specification and is left up to the implementation of the DUT. + +- a. Initiate appropriate action or configuration in the SUT to trigger the RIC Subscription Request from the Near-RT RIC + +Step 4. The Near-RT RIC initiates the RIC Subscription procedure by sending the RIC SUBSCRIPTION REQUEST message to the E2 Node, with the agreed RAN Function Definition IE and measurement information (Measurement Type, Matching Condition and Granularity) + +E2 Node sends RIC SUBSCRIPTION RESPONSE to Near-RT RIC with the list of admitted and not admitted RAN Actions + +E2 Node sends periodic REPORT RIC INDICATION messages for the agreed RAN Function Definition with the agreed Measurement Data to the Near-RT RIC for the UE matching the agreed condition. + +Step 5. Initiate in the Test Equipment the traffic required for the agreed measurement with the selected UE not matching the agreed condition + +E2 Node sends periodic REPORT RIC INDICATION messages for the agreed RAN Function Definition omitting the *List of matched UE IDs* IE + +Step 6. The test is ended after the test duration defined in test entrance criteria, allowing the E2 Node to send several RIC INDICATION messages to the Near-RT RIC. + +#### 7.2.2.1.3.3.3 Expected results + +The test is considered passed if + +- 1) All messages are correctly decoded by the protocol analyzer +- 2) E2 logs recorded in the protocol analyzer are aligned with successful operation message flows specified in [2] clause 8.2. and consistent with the configuration in E2 Node and Near-RT RIC +- 3) RIC Subscription procedure is successful and it is validated in recorded E2 logs that + - *RAN Function ID* IE corresponds to the agreed the RAN Function (during E2 Setup procedure) in both RIC SUBSCRIPTION REQUEST and RIC SUBSCRIPTION RESPONSE messages + - *RIC REQUEST ID* IE is the same as that in the RIC SUBSCRIPTION REQUEST, RIC SUBSCRIPTION RESPONSE and RIC INDICATION messages + - *RIC Action ID* IE is the same as that in the RIC SUBSCRIPTION REQUEST message, in the *RIC Actions Admitted List* IE of the RIC SUBSCRIPTION RESPONSE message and in the RIC INDICATION message + - *RIC Action Definition* IE in the RIC SUBSCRIPTION REQUEST message is E2SM-KPM Action Definition Format 1 with the agreed *Measurement Type* IE and agreed *Matching Condition* IE +- 4) The periodicity of the RIC INDICATION messages in the recorded E2 logs corresponds with the value of *Reporting Period* IE from the *RIC Event Trigger Definition* IE of the RIC SUBSCRIPTION REQUEST message as defined in [5] clause 8.2.1.1.1 +- 5) *Measurement Type* IE in the RIC INDICATION messages is the same as that in RIC SUBSCRIPTION REQUEST message + +- 6) During the period covered by step 4, where the selected UE is matching the agreed condition, the *UE ID IE* of the selected UE in the Test Equipment is present in *List of matched UE IDs IE* of the RIC INDICATION messages sent by the E2 Node +- 7) During the period covered by step 5, where the selected UE is not matching the agreed condition, the *UE ID IE* of the selected UE in the Test Equipment is absent from *List of matched UE IDs IE* of the RIC INDICATION messages sent by the E2 Node. *List of matched UE IDs IE* is omitted if no UE is matching the agreed condition during the reporting period +- 8) Measurements reported by E2 Node in RIC Indication messages are consistent with the traffic simulated by the Test Equipment for the specified UE Id + +If an Error Indication procedure is triggered during the test, then the test result shall be determined as failed. + +If the agreed *RIC Action ID IE* is present in the *RIC Actions Not Admitted List IE* of RIC SUBSCRIPTION RESPONSE message, then the test result shall be determined as failed. + +#### 7.2.2.2 Tests cases for RIC INSERT Service Styles procedures E2SM-KPM + +Note: No test case defined. + +#### 7.2.2.3 Tests cases for RIC CONTROL Service Styles procedures E2SM-KPM + +Note: No test case defined. + +#### 7.2.2.4 Tests cases for RIC POLICY Service Styles procedures E2SM-KPM + +Note: No test case defined. + +#### 7.2.2.5 Tests cases for RIC Subscription Delete procedures E2SM-KPM + +##### 7.2.2.5.1 RIC Subscription Delete procedure with RIC Event Trigger Style 1 + +##### 7.2.2.5.1.1 Test Purpose + +The purpose of this test case is to test the interoperability of Near-RT RIC and E2 Node for RIC Subscription Delete as specified in [2] clause 8.2.2 for Service Model “O-RAN-E2SM-KPM” as specified in [5]. +The expected outcome is successful RIC Subscription Delete procedure by the SUT. + +This test case is mandatory if the SUT (Near-RT and E2 Node) claims to support any RAN function in “O-RAN-E2SM-KPM” Service Model using RIC Event Trigger Style 1. + +##### 7.2.2.5.1.2 Test Entrance Criteria + +- 1) Each element of the SUT (Near-RT RIC and E2 Node) supports a common RAN Function in “O-RAN-E2SM-KPM” Service Model using RIC Event Trigger Style 1 +- 2) Each element of the SUT (Near-RT RIC and E2 Node) supports RIC Subscription Delete procedure for the above RAN Function +- 3) A reporting period for the measurement is agreed and configured in the SUT. The test duration is then selected to allow to cover several reporting periods + +- 7) The RAN Function to which RIC subscribes and the RAN Function definition are predefined and shared between the elements of the SUT (Near RT RIC and E2 Node). A Measurement Type as specified in [5] clause 8.3.9 is agreed to be included in the RIC Subscription. An example of the agreed RAN Function Definition IE defined in [5] clause 8.2.2.1 is shown in table below + +**Table 7.2.2.5.1-1 E2SM KPM Function Definition Profile IE profile** + +| IE Name | Reference | Configuration / Value | +|-------------------------------------------|-----------|----------------------------------------------| +| RAN Function Name | [5] 8.3.2 | | +| >RAN Function Short Name | [5] 8.3.2 | ORAN-E2SM-KPM | +| >RAN Function Service Model OID | [5] 8.3.2 | 1.3.6.1.4.1.53148.1.1.2.2 | +| > RAN Function Description | [5] 8.3.2 | KPM Monitor | +| Sequence of Event Trigger styles | | | +| >RIC Event Trigger Style Type | [5] 8.3.3 | 1 | +| >RIC Event Trigger Style Name | [5] 8.3.4 | Periodic Report | +| >RIC Event Trigger Format Type | [5] 8.3.5 | 1 | +| Sequence of Report styles | | | +| > RIC Report Style Type | [5] 8.3.3 | 1 | +| > RIC Report Style Name | [5] 8.3.4 | E2 Node Measurement | +| > RIC Report Action Format Type | [5] 8.3.5 | 1 | +| > Sequence of Measurement Info for Action | | | +| >> Measurement Type Name | [5] 8.3.9 | Name of one Measurement agreed for this test | +| >RIC Indication Header Format | [5] 8.3.5 | 1 | +| >RIC Indication Message Format | [5] 8.3.5 | 1 | + +- 4) The SUT has functionality to trigger RIC Subscription Delete procedure + +### 7.2.2.5.1.3 Test Methodology + +#### 7.2.2.5.1.3.1 Initial conditions + +- 1) The elements of the SUT (Near-RT RIC and E2 Node) are connected by E2 interface +- 2) E2 Setup procedure is successfully completed in the SUT with the agreed RAN Function Definition IE +- 3) RIC Subscription procedure is successfully completed in the SUT with the agreed RIC Request ID and RAN Function ID + +#### 7.2.2.5.1.3.2 Procedure + +Step 1. Enable the protocol analyzer to capture, record and decode the E2 signalling between SUT elements via the TAP interface. + +Step 2. Perform the RIC Subscription Delete procedure + +An example of how this procedure can be performed (or triggered) is listed below. The exact method to perform (or trigger) this procedure is out of scope of this specification and is left up to the implementation of the DUT. + +- a. Initiate appropriate action or configuration in the SUT to trigger the RIC Subscription Delete procedure + +Near-RT RIC sends the RIC SUBSCRIPTION DELETE REQUEST message to the E2 Node, with the agreed RIC Request ID and RAN Function ID + +E2 Node sends RIC SUBSCRIPTION DELETE RESPONSE to the Near-RT RIC with the agreed RIC Request ID and RAN Function ID + +Step 3. The test is ended after the test duration defined in test entrance criteria, allowing the E2 Node to cover several Reporting periods after the RIC SUBSCRIPTION DELETE RESPONSE message is received + +#### 7.2.2.5.1.3.3 Expected results + +The test is considered passed if + +- 1) All messages are correctly decoded by the protocol analyser +- 2) E2 logs recorded in the protocol analyzer are aligned with successful operation message flows specified in [2] clause 8.2.2. +- 3) RIC Subscription Delete procedure is successful and it is validated in recorded E2 logs that + - *RAN Function ID IE* corresponds to the agreed RAN Function (during E2 Setup procedure and RIC Subscription procedure) in both RIC SUBSCRIPTION DELETE REQUEST and RIC SUBSCRIPTION DELETE RESPONSE messages + - *RIC REQUEST ID IE* is the same as that in RIC SUBSCRIPTION REQUEST, RIC SUBSCRIPTION RESPONSE and RIC INDICATION messages + - *RIC REQUEST ID IE* corresponds to the agreed RIC Request ID (during RIC Subscription procedure) in both the RIC SUBSCRIPTION DELETE REQUEST and RIC SUBSCRIPTION DELETE RESPONSE messages +- 4) No RIC Indication messages are sent for the agreed RAN Function ID and RIC Request ID after the E2 Node sends the RIC SUBSCRIPTION DELETE message + +If an Error Indication procedure is triggered during the test, then the test result shall be determined as failed. + +If RIC SUBSCRIPTION DELETE FAILURE message is sent by E2 Node, then the test result shall be determined as failed. + +### 7.2.3 Test Cases for E2AP Functional Procedures for E2SM-RC + +FFS + +### 7.2.4 Test Cases for E2AP Functional Procedures for E2SM-NI + +FSS + +1 + +## Revision history + +| Date | Revision | Description | +|------------|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2021.08.24 | 00.00.01 | Draft Skeleton Proposal agreed WG3#111 | +| 2022.01.21 | 00.00.02 | Added approved CRs<br>Addition of:<br><VIA-2021.10.28-WG3-CR-0001-Near-RT RIC E2 conformance test configuration-v04> agreed WG3#125<br><VIA-2021.10.28-WG3-CR-0003-Near-RT RIC E2 conformance test case-E2 Setup procedures-v04> agreed#125<br><VIA-2021.10.28-WG3-CR-0002-E2 Interface Test specification-scope and reference-v02> agreed#125 | +| 2022.02.01 | 01.00.03 | Added approved CRs<br>Addition of:<br>< VIA.AO-2021.12.10-WG3-CR-0003-Near-RT RIC E2 conformance test case-RIC Subscription-v03> agreed WG3#129<br>< KEY.AO-2021.11.23-WG3-CR-0002-Near-RT RIC E2 Procedures-NI-Subscription_Report_style_1_V05> agreed WG3#129<br>< KEY-2021.11.18-WG3-CR-0001-Near-RT_RIC_KPM_Subscription_Action_Type1-v06> agreed WG3#129 | +| 2022.02.28 | 01.00.04 | Added approved CRs<br>< TCS.AO-2022.02.01-WG3-CR-0001-Near-RT RIC E2 conformance test case-RIC Subscription Delete-v01> agreed WG3#131<br>< <b>KEY.AO-2022.02.02-WG3-CR-0003-Near_RT_RIC_Reset_RIC_Initiated-v01</b> > agreed WG3#131<br><KEY.AO-2022.02.02-WG3-CR-0004-Near_RT_RIC_Reset_E2_Node_Initiated-v01> agreed WG3#131< <b>KEY.AO-2022.02.03-WG3-CR-0005-E2Node-Setup_Procedure-v01</b> > agreed WG3#131<br>Corrected numbering to position test cases appropriately | + +| | | | +|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.03.29 | 01.00.05 | <p>Added approved CRs</p> <p>Added links to cross referenced clauses, added cross reference for tables, removed unnecessary spaces</p> <p>< JIO.AO-2022.03.28-WG3-CR-0003-Editorial_changes_updated_baseline_v01.docx> agreed WG#138</p> <p><KEY.AO-2022.03.03-WG3-CR-0011-E2Node-E2_Connection_Update_Procedure-v01.docx> agreed WG#138</p> <p><KEY.AO-2022.03.05-WG3-CR-0012-E2-Node_RIC_Subscription_Procedure-v01.docx> agreed WG#138</p> <p><KEY.AO-2022.03.10-WG3-CR-0013-E2-Node_Removal_Procedure-E2_Node_DUT-v01.docx> agreed WG#138</p> <p><KEY.AO-2022.03.02-WG3-CR-0008-E2Node-RIC_Service_Update_Procedure-v01.docx> agreed WG#137</p> <p><VIA.AO-2022.03.14-WG3-CR-0010-Near-RT RIC E2 conformance test case-RIC Control-v01> agreed WG#136</p> <p><VIA.AO-2022.03.14-WG3-CR-0011-E2 Node E2 AP conformance test case-RIC Control-v01> agreed WG#136</p> <p><KEY.AO-2022.03.16-WG3-CR-0018- Adding-additional-level-to-organize-test-cases-v02> agreed WG#136</p> <p><KEY.AO-2022.03.13-WG3-CR-0017-Test-Configuration-Description-E2-Nodes-v01> agreed WG#136</p> <p><KEY.AO-2022.03.12-WG3-CR-0016-E2Node-E2_Node_Configuration_Update_Procedure-v01> agreed WG#136</p> <p><KEY.AO-2022.03.10-WG3-CR-0015-Near-RT RIC-E2_Connection_Update_Procedure-v01> agreed WG#136</p> <p><KEY.AO-2022.03.10-WG3-CR-0014-E2-Node_Removal_Procedure-Near-RT RIC_DUT-v01> agreed WG#136</p> <p><Jio.AO-2022.03.10-WG3-CR-0001-Near-RTRIC-Error_Indication_Procedure-v01> agreed WG#136</p> <p><JIO.AO-2022.03.10-WG3-CR-0002-E2Node-Error_Indication_Procedure-v01> agreed WG#136</p> <p>< KEY.AO-2022.02.22-WG3-CR-0007-Near-RT RIC-RIC_Service_Update_Procedure-v02.docx> agreed WG#135</p> <p>< KEY.AO-2022.03.03-WG3-CR-0009-E2-Node_Reset_Procedure-Near-RT RIC_initiated-v01.docx> agreed WG#135</p> <p>< KEY.AO-2022.03.03-WG3-CR-0010-E2-Node_Reset_Procedure-E2_Node_initiated-v01.docx> agreed WG#135</p> <p>< VIA.AO-2022.03.02-WG3-CR-0004-Near-RT RIC E2 conformance test case-RIC Indication-v01.docx> agreed WG#135</p> <p>< VIA.AO-2022.03.02-WG3-CR-0005-Near-RT RIC E2 conformance test case-KPM Report Service style 1-v01.docx> agreed WG#135</p> <p>< VIA.AO-2022.03.02-WG3-CR-0006-Near-RT RIC E2 conformance test case-KPM Report Service style 2-v01.docx> agreed WG#135</p> <p>< VIA.AO-2022.03.02-WG3-CR-0007-Near-RT RIC E2 conformance test case-KPM Subscription Action type2-v01.docx> agreed WG#135</p> <p>< VIA.AO-2022.03.02-WG3-CR-0009-E2 Node E2 AP conformance test case-RIC Indication-v01.docx> agreed WG#135</p> <p>< VIA.AO-2022.03.02-WG3-CR-0008-Adding Missing Event Trigger to test case 5.2.3.1 KPM_v01.docx> agreed WG#135</p> <p>< TCS.AO-2022.03.08-WG3-CR-0003-E2Node conformance test case-RIC Subscription Delete-v01.docx> agreed WG#135</p> <p>< TCS.AO-2022.03.08-WG3-CR-0004-E2 Node conformance test case-RIC Subscription Delete Required-v02.docx> agreed WG#135</p> <p>< KEY.AO-2022.02.27-WG3-CR-0006-Near-RT RIC E2 Node Configuration Update-v03.docx> agreed WG#134</p> <p>< TCS.AO-2022.02.18-WG3-CR-0002-Near-RT RIC E2 conformance test case-RIC Subscription Delete Required-v01.docx> agreed WG#134</p> | +| 2022.06.29 | 01.00 | Removed third digit from version information. | + +| | | | +|------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.10.25 | 01.00.07 | <p>Added approved CRs</p> <p><TCS.AO-2022.04.15-WG3-CR-0005-E2Node conformance test case-RIC Subscription Delete Request-v02.docx> agreed WG#152</p> <p><KEY.AO-20220705-WG3-CR-0020-Editorial_corrections-v01.docx> agreed WG#162</p> <p><KEY.AO-20220613-WG3-CR-0019-E2_IOT_Testing_Methodology-v04.docx> agreed WG3 Madrid F2F Oct 2022</p> <p><KEY.AO-20220907-WG3-CR-0021-IOT Near-RT RIC support procedures-v05.docx> agreed WG3 Madrid F2F Oct 2022</p> <p><CMCC.AO-2022.10.10-WG3-CR-0001-E2TS Near-RT RIC Conformance E2SM-KPM RIC Subscription procedure negative test cases-v01.docx> agreed WG3 Madrid F2F Oct 2022</p> <p><CMCC.AO-2022.10.10-WG3-CR-0002-E2TS Near-RT RIC Conformance E2SM-KPM RIC Subscription procedure multiple measurements-v01.docx> agreed WG3 Madrid F2F Oct 2022</p> <p><CMCC.AO-2022.10.10-WG3-CR-0003- E2TS Near-RT RIC Conformance E2SM-KPM RIC Indication procedure multiple measurements-v01.docx> agreed WG3 Madrid F2F Oct 2022</p> <p><KEY.AO-20220929-WG3-CR-0022-IOT_E2SM-KPM-v02.docx> agreed WG3 Madrid F2F Oct 2022</p> | +| 2022.11.09 | 01.00.08 | Updated document structure according to new TS template. Change copyright year to be 2023, Ready for WG3 internal review | +| 2022.11.18 | 01.00.09 | <p>Changes reflecting remarks received during WG3 approval process</p> <ul style="list-style-type: none"> <li>- Added R003 to file name</li> <li>- Updated clause 6.2.1.2 heading to Test Cases for RESET procedure</li> <li>- Updated Table of content</li> </ul> | +| 2022.11.20 | 02.00 | Ready for TSC approval and publication | + +## History + +| Date | Revision | Description | +|------------|----------|----------------------------------| +| 2022.04.11 | 01.00.06 | Published as Final version 01.00 | \ No newline at end of file diff --git a/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/05eb3369301d418dcb82876643e3db9f_img.jpg b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/05eb3369301d418dcb82876643e3db9f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7429cee58f6b43bf97b2e7ad3fe464ee11aaefc7 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/05eb3369301d418dcb82876643e3db9f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15547aceb1e524165623668b58b2c28cd3e14dc6c6309b856741316a94e85300 +size 4494 diff --git a/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/1aab5978eb268696232590048d83d4ff_img.jpg b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/1aab5978eb268696232590048d83d4ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cf7b020b570768f3f4d03437451415ca0ea1317b --- /dev/null +++ b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/1aab5978eb268696232590048d83d4ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b2895d1976433aaf9f9eecb52c62c92087c7f75cc832f89f3f716fe53ce061f +size 32791 diff --git a/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/2c020cf57c96b9ded6c32dfbd5c4a316_img.jpg b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/2c020cf57c96b9ded6c32dfbd5c4a316_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1c8f96a05463e44a2f74499b02cb062a13dc8a5c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/2c020cf57c96b9ded6c32dfbd5c4a316_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5855ef53dd183142f2b40ac0419b75c3defe4d61ffdaa43ef256007529f388ab +size 14329 diff --git a/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/9bd7bb64c3d899213c80f6ff21af7b77_img.jpg b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/9bd7bb64c3d899213c80f6ff21af7b77_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..43d05f71aef9ef585ff6a4e3ecf310c03d9fe151 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/9bd7bb64c3d899213c80f6ff21af7b77_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d7d177824dad8cb18b2a4f0cdea2d2df13972e51da80817aa4803c0a686296f9 +size 4564 diff --git a/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/c1bc15cc1c93c930f668b9979c99952d_img.jpg b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/c1bc15cc1c93c930f668b9979c99952d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b9fdb5d4483155dcf5045b4adb409a04e1e24730 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/c1bc15cc1c93c930f668b9979c99952d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1a36d92dd3cdb88dfc7aeb1c462abd13de46f3cbf405724339367dcc72700366 +size 4566 diff --git a/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/d4f829b4c875afdb0fe6a20463ac26ae_img.jpg b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/d4f829b4c875afdb0fe6a20463ac26ae_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c7679364a72be57ec5118614e7da624fa34275b6 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/d4f829b4c875afdb0fe6a20463ac26ae_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6df31458c9add59bf46339bd33f3c18df970b2cceb13ff401a84ae7531709f70 +size 51144 diff --git a/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/f68868d74f079154c466be691f350601_img.jpg b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/f68868d74f079154c466be691f350601_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3149978d7a19a8d9ec2ce359b0201fb5f463c28a --- /dev/null +++ b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/f68868d74f079154c466be691f350601_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:06e60c388a0cd9d8974496cf63b8b465e7eb8291937b0bc09fb27b20ec691a53 +size 16658 diff --git a/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/raw.md b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..1c22c1d988440570192f96f7ee57f71a01efb9d8 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00/raw.md @@ -0,0 +1,426 @@ + + +![O-RAN ALLIANCE logo](9bd7bb64c3d899213c80f6ff21af7b77_img.jpg) + +The logo for O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient, followed by 'RAN' in blue and 'ALLIANCE' in smaller blue letters below. + +O-RAN ALLIANCE logo + +# O-RAN.WG3.O1-Interface-for-NearRT-RIC- R003-v01.00 + +*Technical Specification* + +## **O-RAN Work Group 3 O1 Interface Specification for Near Real Time RAN Intelligent Controller** + +Copyright © 2023 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|--------------------------------------------------------|----| +| Foreword..... | 3 | +| Modal verbs terminology ..... | 3 | +| 1 Scope..... | 4 | +| 2 References ..... | 4 | +| 2.1 Informative references ..... | 4 | +| 3 Definition of terms, symbols and abbreviations ..... | 5 | +| 3.1 Terms ..... | 5 | +| 3.2 Symbols..... | 5 | +| 3.3 Abbreviations..... | 5 | +| 4 Management Services ..... | 6 | +| 4.1 Provisioning Management Services..... | 6 | +| 4.2 Fault Supervision Management Services..... | 6 | +| 4.2.1 Requirements..... | 6 | +| 4.3 Performance Assurance Management Services ..... | 6 | +| 4.4 Trace Management Services ..... | 6 | +| Revision history ..... | 12 | + +# --- Foreword + +This Technical Specification (TS) has been produced by the O-RAN Alliance. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document defines O-RAN OAM interface functions and protocols for the O-RAN O1 interface for the Near RT RIC. The document studies the functions conveyed over the interface, including management functions, procedures, operations, and corresponding solutions, and identifies existing standards and industry work that can serve as a basis for O-RAN work. + +This document will follow the requirements specification language defined in IETF RFC 2119 [33] updated by RFC 8174 [37]. For consistency requirements are specified using “SHALL” to indicate that the implementation is required. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications” +- [2] O-RAN-WG3.E2GAP, “O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 General Aspects and Principles”. +- [3] O-RAN-WG3.E2AP, “O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Application Protocol (E2AP)”. +- [4] O-RAN-WG1.OAM Architecture, “O-RAN Operations and Maintenance Architecture”. +- [5] O-RAN-WG1.O1-Interface, “O-RAN Operations and Maintenance Interface Specification”. +- [6] 3GPP TS 33.401: “3GPP System Architecture Evolution (SAE); Security architecture”. +- [7] 3GPP TS 33.501: “Security architecture and procedures for 5G System”. +- [8] O-RAN-WG2.A1.GA&P, “O-RAN Working Group 2, A1 interface: General Aspects and Principles”. + +- [9] O-RAN-WG2.A1AP, “O-RAN Working Group 2, A1 Interface: Application Protocol”. +- [10] O-RAN-WG1.O-RAN Architecture, “O-RAN Working Group 1, O-RAN Architecture Description”. +- [11] 3GPP TS 36.401: "Evolved Universal Terrestrial Radio Access Network (E-UTRAN); Architecture Description". +- [12] 3GPP TS 38.300: “NR; NR and NG-RAN Overall Description; Stage 2”. +- [13] 3GPP TS 37.324: “Evolved Universal Terrestrial Radio Access (E-UTRA) and NR; Service Data Adaptation Protocol (SDAP) specification”. +- [14] 3GPP TS 38.331: “NR; Radio Resource Control (RRC); Protocol specification”. +- [15] 3GPP TS 38.323: “NR; Packet Data Convergence Protocol (PDCP) specification”. +- [16] 3GPP TS 38.322: “NR; Radio Link Control (RLC) protocol specification”. +- [17] 3GPP TS 38.321: “NR; Medium Access Control (MAC) protocol specification”. +- [18] 3GPP TS 38.201: “NR; Physical layer; General description”. +- [19] O-RAN WG10: O-RAN Information Model and Data Models Specification, +- [20] O-RAN WG3.RICARCH-v02.00 +- [21] 3GPP TS 28.622: “Generic Network Resource Mode (NRM) ” +- [22] O-RAN WG1.Information Model and Data Models-v01.00 +- [23] AlarmDictionaryModel-2021-07.11-13645 +- [24] 3GPP TS 28.541: “Management and orchestration; 5G Network Resource Model (NRM)” + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms [given in [i.1] and the following] apply: + +N/A + +## 3.2 Symbols + +For the purposes of the present document, the symbols [given in [i.1] and the following] apply: + +N/A + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations [given in [i.1] and the following] apply: + +| | | +|-------|---------------------------------------------------------| +| FCAPS | Fault, Configuration, Accounting, Performance, Security | +| FM | Fault Management | +| IOC | Information Object Class | +| ME | Managed Element | + +| | | +|-------------|----------------------------------------------------| +| MF | Managed Function | +| MnS | Management Service | +| MO | Managed Object | +| MOI | Managed Object Instance | +| Near-RT RIC | O-RAN Near Real Time RAN Intelligent Controller | +| NETCONF | NETwork CONFiguration protocol | +| NF | Network Function | +| Non-RT RIC | O-RAN Non-Real Time RAN Intelligent Controller | +| PM | Performance Management or Performance Measurements | +| SMO | Service Management and Orchestration | +| TR | Technical Report | + +# --- 4 Management Services + +## 4.1 Provisioning Management Services + +Provisioning Management Services MnS for Near RT RIC platform shall be aligned with [5], Chapter 2.1 + +## 4.2 Fault Supervision Management Services + +Fault Supervision MnS for Near RT RIC platform shall be aligned with [5], Chapter 2.2 + +### 4.2.1 Requirements + +Fault Management for the Near-RT RIC Platform is based on the O-RAN-WG1.O1-Interface, “O-RAN Operations and Maintenance Interface Specification [5] + +The relevant sections are: + +- 4.1.10 Subscription Control +- 4.2.1 Fault Notification +- 4.2.2 Fault Supervision Control + +## 4.3 Performance Assurance Management Services + +Performance Assurance Management Services MnS for Near RT RIC platform shall be aligned with [5], Chapter 2.3 + +## 4.4 Trace Management Services + +# 5 Model + +## 5.1 Imported and associated information entities + +### 5.1.1 Imported information entities and local labels + +| Label reference | Local label | +|----------------------------------------------|--------------------| +| TS 28.622 [21], IOC, ManagedFunction | ManagedFunction | +| TS 28.622 [21], IOC, EP_RP | EP_RP | +| O-RAN.WG10.Information Model and Data Models | ManagedApplication | + +### 5.1.2 Associated information entities and local labels + +| Label reference | Local label | +|-------------------------------------|----------------| +| TS 28.622 [21], IOC, ManagedElement | ManagedElement | + +## 5.2 Class Diagrams + +### 5.2.1 Relationships + +``` + +@startuml +skinparam ClassStereotypeFontStyle normal +hide empty members + +class ManagedElement <<InformationObjectClass>> +class "NearRTRICFunction" as ric <<InformationObjectClass>> +class "EP_E2" as E2 <<InformationObjectClass>> +class "E2 Node" as bts <<proxyClass>> + +ric "*" -d-* "1" ManagedElement : <<names>> +ric "1" *-right-* E2 : <<names>> + +E2 "*" -right-> " 0..1" bts : " +note top of bts +Proxy class representing +any of the following E2 EndPoints: +O-CU-CP +O-CU-UP +O-DU +O-eNB +end note +@enduml + +``` + +![UML Class Diagram for Near RT RIC Containment](d4f829b4c875afdb0fe6a20463ac26ae_img.jpg) + +``` + +classDiagram + class ManagedElement["«InformationObjectClass» ManagedElement"] + class NearRTRICFunction["«InformationObjectClass» NearRTRICFunction"] + class EP_E2["«InformationObjectClass» EP_E2"] + class E2Node["«proxyClass» E2 Node"] + + ManagedElement "1" -- "*" NearRTRICFunction : «names» + NearRTRICFunction "1" -- "*" EP_E2 : «names» + EP_E2 "*" -- "0..1" E2Node + +``` + +Proxy class representing any of the following E2 EndPoints: +O-CU-CP +O-CU-UP +O-DU +O-eNB + +UML Class Diagram for Near RT RIC Containment + +Figure 5.2.1-1: Near RT RIC Containment + +Further disaggregation of the internal NearRTRICFunction management is FFS. + +### 5.2.2 Inheritance + +``` + +@startuml +hide empty members +skinparam ClassStereotypeFontStyle normal +class NearRTRICFunction <<InformationObjectClass>> +abstract ManagedFunction <<InformationObjectClass>> +ManagedFunction <|-- NearRTRICFunction +@enduml + +``` + +![UML Class Diagram for Near-RT RIC Function inheritance](f68868d74f079154c466be691f350601_img.jpg) + +``` + +classDiagram + class ManagedFunction["«InformationObjectClass» ManagedFunction"] + class NearRTRICFunction["«InformationObjectClass» NearRTRICFunction"] + + ManagedFunction <|-- NearRTRICFunction + +``` + +UML Class Diagram for Near-RT RIC Function inheritance + +Figure 5.2.2-1: Near-RT RIC Function inheritance + +``` + +@startuml +hide empty members +skinparam ClassStereotypeFontStyle normal +abstract class EP_RP <<InformationObjectClass>> +class EP_E2 <<InformationObjectClass>> +EP_RP <|-- EP_E2 +@enduml + +``` + +![UML class diagram showing inheritance from EP_RP to EP_E2. EP_RP is an InformationObjectClass with a blue circle 'A' in the top left corner. EP_E2 is an InformationObjectClass with a green circle 'C' in the top left corner. A red arrow points from EP_E2 to EP_RP.](2c020cf57c96b9ded6c32dfbd5c4a316_img.jpg) + +``` + +classDiagram + class EP_RP["«InformationObjectClass»\nEP_RP"] + class EP_E2["«InformationObjectClass»\nEP_E2"] + EP_E2 --|> EP_RP + +``` + +UML class diagram showing inheritance from EP\_RP to EP\_E2. EP\_RP is an InformationObjectClass with a blue circle 'A' in the top left corner. EP\_E2 is an InformationObjectClass with a green circle 'C' in the top left corner. A red arrow points from EP\_E2 to EP\_RP. + +Figure 5.2.2-2: EP\_E2 Inheritance + +``` + +@startuml xApp inheritance (2022-11-04) + +skin rose +skinparam ClassStereotypeFontStyle normal +skinparam style strictuml +hide empty members + +abstract class ManagedApplication <<InformationObjectClass>> +class TrafficSteeringFunction <<InformationObjectClass, FFS/example>> +ManagedApplication <|-d- TrafficSteeringFunction + +note right of ManagedApplication + defined in WG10 IM/DM + clause 3.5.3.1 +end note + +note right of TrafficSteeringFunction + WG3 work in progress + and other "future" Functions +end note + +@enduml + +``` + +![UML class diagram showing inheritance from ManagedApplication to TrafficSteeringFunction. ManagedApplication is an InformationObjectClass with a note 'defined in WG10 IM/DM clause 3.5.3.1'. TrafficSteeringFunction is an InformationObjectClass, FFS/example with a note 'WG3 work in progress and other "future" Functions'. A red arrow points from TrafficSteeringFunction to ManagedApplication.](1aab5978eb268696232590048d83d4ff_img.jpg) + +``` + +classDiagram + class ManagedApplication["«InformationObjectClass»\nManagedApplication"] + class TrafficSteeringFunction["«InformationObjectClass, FFS/example»\nTrafficSteeringFunction"] + TrafficSteeringFunction --|> ManagedApplication + +``` + +UML class diagram showing inheritance from ManagedApplication to TrafficSteeringFunction. ManagedApplication is an InformationObjectClass with a note 'defined in WG10 IM/DM clause 3.5.3.1'. TrafficSteeringFunction is an InformationObjectClass, FFS/example with a note 'WG3 work in progress and other "future" Functions'. A red arrow points from TrafficSteeringFunction to ManagedApplication. + +NOTE: This figure will be removed in the next version of the current document and replaced by one or more concrete xApp Use Cases + +Figure 5.2.2-2: Example of inheritance from *ManagedApplication* + +## 5.3 Class Definitions + +### 5.3.1 NearRTRICFunction + +#### 5.3.1.1 Definition + +The NearRTRICFunction IOC represents the Management aspects of the aggregated functions making up the Near-Rt RIC defined in clause 4.3.2 of O-RAN.WG1.O-RAN-Architecture-Description. + +#### 5.3.1.2 Attributes + +The NearRTRICFunction IOC includes the attributes below and those attributes inherited through *ManagedFunction* IOC (defined in TS 28.622 [21]). + +| Attribute Name | S | isReadable | isWritable | isInvariant | isNotifyable | +|--------------------------------------------|---|------------|------------|-------------|--------------| +| PLMN Identity (3GPP 38.423 Clause 9.2.2.4) | M | T | T | F | T | +| Near-RT RIC ID | M | T | T | F | T | +| <b>Attribute related to role</b> | | | | | | +| applicationDNList | M | T | T | F | T | + +#### 5.3.1.3 Attribute constraints + +None + +#### 5.3.1.4 Notifications + +None + +### 5.3.2 EP\_E2 + +The common notifications defined in clause 4.5 in TS 28.622 [21] are valid for this IOC + +#### 5.3.2.1 Definition + +The EP-E2 IOC represents the Management aspects of the E2T defined in RICArch [4] section 6.2. + +#### 5.3.2.2 Attributes + +The EP\_E2 IOC includes the attributes below and those attributes inherited through EP\_RP IOC (defined in TS 28.622 [21]) + +| Attribute Name | S | isReadable | isWritable | isInvariant | isNotifyable | +|-----------------|---|------------|------------|-------------|--------------| +| tRICEventCreate | O | T | T | F | T | +| tRICEventDelete | O | T | T | F | T | +| tRICControl | O | T | T | F | T | +| | | | | | | + +#### 5.3.2.3 Attribute constraints + +None + +#### 5.3.2.4 Notifications + +None + +## 5.5 Attribute definitions + +### 5.5.1 Attribute properties + +| Attribute Name | Documentation and Allowed Values | Properties | +|-------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------| +| tRICEventCreate | Defined in O-RAN.WG3.E2AP Clause 9.5<br>Specifies the maximum time for the RIC Subscription Request event creation procedure in the E2 Node.<br><br>allowedValues: [0..4095] ms | type: Integer<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: Null<br>isNullable: True | +| tRICEventdelete | Defined in O-RAN.WG3.E2AP Clause 9.5<br>Specifies the maximum time for the RIC Subscription Request event deletion procedure in the E2 Node.<br><br>allowedValues: [0..4095] ms | type: Integer<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: Null<br>isNullable: True | +| tRICControl | Defined in O-RAN.WG3.E2AP Clause 9.5<br>Specifies the maximum time for the RIC Control Request event request procedure in the E2 Node.<br><br>allowedValues: [0..4095] ms | type: Integer<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: Null<br>isNullable: True | +| applicationDNList | This attribute contains the DNs of the hosted applications (MOIs of the concrete IOCs inheriting from ManagedApplication).<br><br>allowedValues: Not applicable. | type: DN<br>multiplicity: 0..*<br>isOrdered: False<br>isUnique: True<br>defaultValue: None<br>isNullable: False | +| nearRTRICID | Defined in O-RAN.WG3.E2AP-v02.01 Clause 9.2.4 | | +| pLMNIdentity | Defined in 3GPP 38.423 Clause 9.2.2.4 | | + +# --- Revision history + +| Date | Revision | Description | +|------------|----------|------------------------------------------------------------------| +| 2021.09.27 | 00.00.01 | First draft of O-RAN OAM Interface Specification for Near RT RIC | +| 2021.11.05 | 00.00.02 | Incorporating CRs NOK0001 and NOK0002 | +| 2022.01.08 | 00.00.03 | Document updated to incorporate CRs NOK0003 and CR NOK0007 rev8 | +| 2022.07.20 | 00.00.04 | New Baseline | +| 2022.11.09 | 00.00.05 | Baseline for November train | +| 2022.11.17 | 00.00.06 | Addressing review comments | +| 2022.11.18 | 01.00 | Candidate for November train | \ No newline at end of file diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/1bec1afab6abca1a19ce48cc07e855c1_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/1bec1afab6abca1a19ce48cc07e855c1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9aff2a7d9eec4ce26bbff80740697d9de800a348 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/1bec1afab6abca1a19ce48cc07e855c1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:78a0235e7230086367d0cbf0cd7c68b42239ee18120fa610bbded8cbd4bdfa16 +size 68077 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/31f141cb102bc2873bc22577f8ff1a8b_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/31f141cb102bc2873bc22577f8ff1a8b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e16debd008521ff41dc6fe5227a3be03ece67a5d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/31f141cb102bc2873bc22577f8ff1a8b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e821995a69d84ea6ab2acce607f6cb395188eaa9a67def150b64d1a9449a1c3f +size 158359 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/3b5a689f132b8f48289c3bf846ffbb98_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/3b5a689f132b8f48289c3bf846ffbb98_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ac93cd31d2d316c50ed39d069ad39fc525ecad7a --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/3b5a689f132b8f48289c3bf846ffbb98_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1467660ec85f1549a30166da479c719c460889bd473fe50555e23e00798c2c91 +size 100720 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/807431d112ae65d5ff9bc8cc7e37956a_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/807431d112ae65d5ff9bc8cc7e37956a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f124de986ff35f3c53cf656ebbe287e3e905f309 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/807431d112ae65d5ff9bc8cc7e37956a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:40c09bc00820adf5adfb11beec38123b6a23b7d727a87cbdd69453478873b92e +size 72600 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/9065363d36872d8ba7e99fafb8577f31_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/9065363d36872d8ba7e99fafb8577f31_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8220cfe9981f18a287f4d57dd15daf702b687792 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/9065363d36872d8ba7e99fafb8577f31_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7ebc507f89aadebfc33eece1914e1e0a729131a002e5a0260a923569ea636f15 +size 102166 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/a2969a6f33ca6ff2faddd5878fc418ef_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/a2969a6f33ca6ff2faddd5878fc418ef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b97fabfcb0f9b4297b093e32542f6b3a4fd79b5e --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/a2969a6f33ca6ff2faddd5878fc418ef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2cdc913b7f9a44372f0eff125e2c2a0ec4632a00672db9afe0ca5912fa3a5cdb +size 88547 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d73ac8b8be38faf362b1eaa59fff1f3f167364fb --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3276e59412020445a9dbac9cf2ede064a279427afdcaa0dcf94fa0620d916726 +size 4546 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/d8c8ad20c2d438a0c8211457311b4fd4_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/d8c8ad20c2d438a0c8211457311b4fd4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d69efaf1fa848abff85a9a24954b52cf1890a94 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/d8c8ad20c2d438a0c8211457311b4fd4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:be03730d8b8ca029e4d9d5d5fb14c055802da3023cf0012498d50c0d6aea1baa +size 123556 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/e548714edc96b1dc582a4ba53ad220d2_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/e548714edc96b1dc582a4ba53ad220d2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f74751b0396138aa783fcf0945ea4f125b038479 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/e548714edc96b1dc582a4ba53ad220d2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9832bdd67b7e063dbc4af0e893ecb1e7905664b4165605de8e40fb87b2e867f6 +size 4528 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/e65a45bef5994155c50ca1c83f083d23_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/e65a45bef5994155c50ca1c83f083d23_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e8f403f49c6a6bf6e9368fab06183b36564bf13e --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/e65a45bef5994155c50ca1c83f083d23_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f6eb7aad683cf5d83818d7eaf736b5e659c0fcc68c8ff1c67576c41affe86294 +size 125103 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/eb4e45abf03e04626c32b064706cc3f6_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/eb4e45abf03e04626c32b064706cc3f6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e0cdbd0f84434013740cb7dc8a9a896947397fef --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/eb4e45abf03e04626c32b064706cc3f6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5942b2f73c1ce771e664c6d9fafcc8ceaf3c46e68f044d9c7b0385b3be72bb7a +size 4529 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/raw.md b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..6d903033c9be70093989ced0195eaa92819ef028 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00/raw.md @@ -0,0 +1,1661 @@ + + +# --- **O-RAN Work Group 3 (Near-Real-time RAN Intelligent Controller and E2 Interface)****Conflict Mitigation** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|-----------------------------------------------------------------------------------------------------------------------------------------------|----| +| List of figures ..... | 4 | +| List of tables ..... | 4 | +| Foreword ..... | 5 | +| Modal verbs terminology ..... | 5 | +| 1 Scope ..... | 6 | +| 2 References ..... | 6 | +| 2.1 Informative references ..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 6 | +| 3.1 Terms ..... | 6 | +| 3.2 Symbols ..... | 6 | +| 3.3 Abbreviations ..... | 6 | +| 4 Background and Concepts ..... | 7 | +| 4.1 Background ..... | 7 | +| 4.2 Concepts ..... | 7 | +| 4.2.1 Types of Conflicts ..... | 7 | +| 4.2.2 Framework for Conflict Mitigation ..... | 8 | +| 4.3 Working Principles ..... | 8 | +| 5 Conflict Detection ..... | 9 | +| 5.1 Key Issues ..... | 9 | +| 5.1.1 Key Issue #1 Detection of E2-related Potential Conflicts ..... | 9 | +| 5.1.2 Key Issue #2 Detection of E2-related Direct Conflicts ..... | 9 | +| 5.1.3 Key Issue #3 Detection of E2-related Indirect and/or Implicit Conflicts ..... | 10 | +| 5.2 Solutions ..... | 11 | +| 5.2.1 Solution #1 E2AP level direct conflict detection by Near-RT RIC platform ..... | 11 | +| 5.2.2 Solution #2 E2SM level direct conflict detection by Near-RT RIC platform ..... | 12 | +| 5.2.3 Solution #3 E2SM level direct conflict detection by xApps ..... | 13 | +| 5.2.4 Solution #4 Post-Action Detection of E2-related Indirect and/or Implicit Conflicts ..... | 18 | +| 5.2.5 Solution #5 Pre-Action Detection of E2-related Indirect Conflicts with user configured parameter dependency information ..... | 26 | +| 5.2.6 Solution #6 Pre-Action Detection of Potential E2-related Implicit Conflicts with user configured parameter dependency information ..... | 28 | +| 5.2.7 Solution #7 Pre-Action Detection of E2-related Implicit Conflicts with with user configured parameter dependency information ..... | 30 | +| 5.3 Solutions-to-Key Issues Mapping ..... | 32 | +| 6 Conflict Resolution ..... | 32 | +| 6.1 Key Issues ..... | 32 | +| 6.1.1 Key Issue #1 Resolution of E2-related Conflicts ..... | 32 | +| 6.2 Solutions ..... | 33 | +| 6.2.1 Solution #1 Resolution of Direct Parameter Conflicts between xApps at E2SM level ..... | 33 | +| 6.3 Solutions-to-Key Issues Mapping ..... | 39 | +| 7 Conflict Avoidance ..... | 39 | +| 7.1 Key Issues ..... | 39 | +| 7.1.1 Key Issue #1 Avoidance of E2-related Conflicts ..... | 39 | +| 7.2 Solutions ..... | 41 | +| 7.2.1 Solution #1 xApp based E2SM level service conflict avoidance ..... | 41 | +| 7.3 Solutions-to-Key Issues Mapping ..... | 47 | +| 8 Conclusions ..... | 47 | + +| | | | +|------------------------------------------------------|------------------------------------------|----| +| 8.1 | Conflict Detection ..... | 47 | +| 8.1.1 | Key issues and potential solutions ..... | 47 | +| 8.1.2 | Solution requirements ..... | 47 | +| 8.2 | Conflict Resolution ..... | 48 | +| 8.2.1 | Key Issues and potential solutions ..... | 48 | +| 8.2.2 | Solution requirements ..... | 48 | +| 8.3 | Conflict Avoidance ..... | 48 | +| 8.3.1 | Key Issues and potential solutions ..... | 48 | +| 8.3.2 | Solution requirements ..... | 48 | +| Annex A: Title of annex ..... | | 50 | +| Annex Bibliography ..... | | 51 | +| Annex: Change history/Change request (history) ..... | | 52 | + +# --- List of figures + +| | | +|----------------------------------------------------------------------------------------------------|----| +| Figure 5.2-1: RICARCH Figure 9.3.3.1-1: xApp initiated E2 guidance request/response procedure..... | 15 | +| Figure 5.2-2: RICARCH Figure 9.3.3.5-1 E2 Guidance Modification Procedure..... | 16 | +| Figure 5.2-3: Implementation Option 1 (Platform Handles E2SM)..... | 21 | +| Figure 5.2-4: Implementation Option 2 (Helper xApp Handles E2SM)..... | 24 | +| Figure 6.2-1: Implementation Option 1 (Platform Handles E2SM)..... | 29 | +| Figure 6.2-2: Implementation Option 2 (Helper xApp Handles E2SM)..... | 31 | +| Figure 7.2-1: RICARCH Figure 9.3.3.1-1: xApp initiated E2 guidance request/response procedure..... | 38 | +| Figure 7.2-2: RICARCH Figure 9.3.3.5-1 E2 Guidance Modification Procedure..... | 40 | + +# --- List of tables + +| | | +|--------------------------------------------------|---| +| Table 5.3-1: Solutions to Key Issue Mapping..... | 7 | +| Table 6.3-1: Solutions to Key Issue Mapping..... | 8 | +| Table 7.3-1 Solutions to Key Issue Mapping..... | 9 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG3 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document provides a technical report on the Conflict Mitigation functions in the Near-RT RIC. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [i.1] O-RAN.WG3.RICARCH-v05.00.00: “O-RAN, Near-Real-time RAN Intelligent Controller, Near-RT RIC Architecture”. +- [i.2] ORAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Service Model, RAN Control (E2SM-RC). + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +## 3.2 Symbols + +## 3.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply: + +| | | +|-------------|-------------------------------------------| +| API | Application Programming Interface | +| CCO | Coverage and Capacity Optimization | +| ConMit | Conflict Mitigation | +| E2SM | E2 Service Model | +| KPI | Key Performance Indicator | +| MRO | Mobility Robustness Optimization | +| Near-RT RIC | Near-Real-time RAN Intelligent Controller | +| RAN | Radio Access Network | +| RICARCH | RAN Intelligent Controller Architecture | +| SMO | Service Management and Orchestration | + +# --- 4 Background and Concepts + +## 4.1 Background + +The principle that the Near-RT RIC includes support for Conflict Mitigation has been part of RICARCH [i.1] since the first version was published in 2021. Conflict Mitigation in Near-RT RIC is a necessary functionality because xApps objectives may be chosen/configured such that they result in conflicting actions. Since then, however, the only change has been the addition of "E2 Guidance" procedure into clause 9.3 [i.1] for E2 Subscription and E2 Control procedures and the split of the v01.00 text into a brief statement in clause 6.2.3 and additional details in Annex A. + +This state is sufficient if the Near-RT RIC platform hosts all aspects of conflict mitigation and hence but is insufficient, if, and when, deeper analysis reveals new requirements related to conflict mitigation that involve either inter-action with xApps and/or the SMO domain. + +The purpose of the TR is therefore an analysis of the different types of conflicts defined in clause 4.2.1 in terms of methods for Conflict Detection, Resolution and Avoidance with the objective of identifying when and if new RIC APIs, new O1 use cases, and/or extensions to E2SMs are required to support Conflict Mitigation. This identification shall result in "key issues" and their "potential solutions" for Conflict Detection, Resolution and Avoidance. + +## 4.2 Concepts + +### 4.2.1 Types of Conflicts + +Conflicts between xApps can be broadly divided into three types. + +1- Direct Conflicts: The conflicts can be observed directly. Some cases are described as below: + +- Two or more xApps request different settings for the very same configuration of one or more control parameters. +- The new control or policy request from an xApp may conflict with the running configuration resulting from a previous request of another or the same xApp. +- Two xApps may not be provided services by a RAN Function simultaneously, e.g., due to lack of sufficient resources. In this sense, the two xApps shall directly compete for the same RAN resource. + +2- Indirect Conflicts: The conflicts cannot be observed directly, nevertheless, some dependence among the parameters and resources that the xApps target can be observed. For instance, different xApps target different configuration parameters to optimize the same metric according to their respective objectives. Even though this will not result in conflicting parameter settings, it may have uncontrollable or inadvertent system impacts. One example of such indirect conflicts can occur when the changes required by one xApp create a system impact which is equivalent to a parameter change targeted by another xApp. For example, antenna tilts and measurement offsets are different control points, but they both impact the handover boundary. + +- 3- Implicit Conflicts: The conflicts cannot be observed directly, even the dependence between xApps is not obvious. For instance, different xApps may optimize different metrics and (re-)configure different parameters. Nonetheless, optimizing one metric may have implicit, unwanted, and maybe adversary side effects on one of the metrics optimized by another xApp. E.g., protecting throughput metrics for GBR users may degrade non-GBR metrics or even cell throughput. + +### 4.2.2 Framework for Conflict Mitigation + +A comprehensive Conflict Mitigation framework consists of three procedures: + +- 1- Conflict Detection: Detection of potential and actual direct, indirect, and implicit conflicts. +- 2- Conflict Resolution: Resolution of ongoing conflicts, possibly beyond simple xApp enablement or disablement. +- 3- Conflict Avoidance: Providing guidance and information to xApps in order to avoid future conflicts. + +The above procedures should be enabled to make use of Near RT RIC platform functionalities and they may require services provided by xApps. These services and functionalities may include AI/ML methods and optimization techniques etc. For this reason, the above procedures may be seen as “use-cases”. However, these use-cases do not deal with network performance KPIs directly, such as the use-cases considered in UCTG WG1. In contrast, these procedures enable xApps to execute their business logic safely in an environment in which there could be many multi-vendor xApps with different business logic and objectives. + +It is clear that the above procedures are potentially more “intelligent” than other native functionalities of Near RT RIC platform such as data base, AI/ML training, xApp subscription management etc. In particular, Conflict Mitigation is likely to need to decode/understand E2SM level data such as network KPIs and control parameters. + +One design option would be to introduce support for specialized "conflict mitigation related xApps" to perform these roles. This approach opens up a significant opportunity for companies to develop intelligent solutions, in form of xApps, that provide conflict mitigation related value added services to Conflict Mitigation in the platform. + +The above text discusses only discusses a few possibilities that may be considered. The precise "key Issues" arising in the Conflict Mitigation framework and their solutions shall be discussed in detail in Chapters 5, 6, and 7. + +## 4.3 Working Principles + +In light of the RIC ARCH specification [i.1] clause 6.2.3 and the WI description, the current scope of this TR is restricted to mitigation of conflicts in xApp actions over the E2 interface. The motivations behind xApp actions (e.g., O1 configuration or A1 policies etc.) are not covered currently by the TR in context of conflict mitigation. However, this work may serve as the basis for and complimentary to further future work covering A1 and O1 aspects as well. + +# --- 5 Conflict Detection + +## 5.1 Key Issues + +### 5.1.1 Key Issue #1 Detection of E2-related Potential Conflicts + +#### 5.1.1.1 Description + +Potential conflicts (i.e., future probable conflicts) between xApp actions may be detected *pre-action* by the Near-RT RIC platform, i.e., before RIC Control Request or RIC Subscription Request messages are sent to the E2 Node. At least for direct conflicts, this conflict mitigation functionality shall allow for pre-action xApp conflict resolution and conflict avoidance. Information obtained from this procedure may be used during confirmation/detection of actual conflicts discussed in later clauses. + +NOTE: This key issue is restricted to only pre-action detection of “potential” conflicts, i.e., these conflicts may demand further investigation, but they may not result in “actual” conflicts discussed in later clauses. + +#### 5.1.1.2 Impacted Use-Cases + +All use cases impacted by, at least, E2-related direct conflicts. See clause 5.1.2.2. + +#### 5.1.1.3 Considerations + +The following considerations should be kept in mind when providing solutions to this key issue: + +- 1- Near-RT RIC platform’s conflict mitigation (ConMit) functionality may be used. The platform may obtain information from xApp Subscription Management to perform this task. + - a. The detection of potential conflicts by the ConMit functionality may be restricted to using only E2AP level information. +- 2- The xApp control actions do not need to be simultaneous for them to cause conflicts. For example, if an xApp’s control target is a particular cell, then it may “potentially” cause a conflict with an existing running xApp subscription whose control target is the same cell. +- 3- Because xApps are likely to repeat their behavior, previously detected potential conflicts may be considered for future E2 Guidance [i.1]. + +#### 5.1.1.4 Open issues + +void. + +### 5.1.2 Key Issue #2 Detection of E2-related Direct Conflicts + +#### 5.1.2.1 Description + +Direct conflicts occur due to overlapping RAN Parameters and/or overlapping RAN resources between xApps, e.g., when two xApps request to configure the same RAN parameter(s). See clause 4.2.1 for description of conflict types. + +#### 5.1.2.2 Impacted Use-Cases + +Several use-cases may share the same control parameter, or more generally, access the same RAN resources. For example, handover parameters may be configured by xApps for Mobility Robustness Optimization (MRO), Traffic Steering and/or Load-Balancing. + +#### 5.1.2.3 Considerations + +The following considerations should be kept in mind when providing solutions to this key issue: + +- 1- Detection of direct conflicts may use E2AP and/or E2SM specific information. +- 2- Detection of direct conflicts may happen after further investigation of detected potential conflicts. + - a. For example, even if two or more xApps target the same RAN control parameter(s), which may indicate a potential conflict, their specific control or policy actions may ultimately decide whether the resulting configurations are conflicting. A typical example of a direct conflict is when the first xApp suggests increasing the value of a RAN control parameter while the second xApp suggests decreasing it. +- 3- Conflicts may be detected pre-action (i.e., before RIC Control Request or RIC Subscription Request messages have been sent to the E2 Node) or post-action (i.e., after RIC Control Request or RIC Subscription Request messages have been sent to the E2 Node). +- 4- xApps actions may be conflicting directly even if they are not simultaneous. +- 5- Direct conflicts may not just involve RAN control parameters. Two xApps may request the same RAN resources or the sum of RAN resources required by xApps may exceed the capacity of the RAN node. +- 6- If the two xApps target different KPIs, then KPI improvement/degradation or potential KPI improvement/degradation and their relative importance may also be considered at this stage. For example, if actions of one xApp do not degrade KPIs of other xApps, then this may not be considered as a conflict. + +#### 5.1.2.4 Open issues + +The following issues are open: + +- 1- If E2SM-specific information is used to detect conflicts, it's unclear whether E2SM inspection may be performed by the platform or by the conflicting xApps through direct or indirect communication. +- 2- If the detection is performed by the platform using E2SM-specific information, the platform shall need to “understand/decode” this information. + - a. Privacy Issue: The platform may not have access to E2SM information specific to an xApp. For example, the platform may not have access to details of xApp’s E2SM control/policies. + +### 5.1.3 Key Issue #3 Detection of E2-related Indirect and/or Implicit Conflicts + +#### 5.1.3.1 Description + +During indirect and/or implicit conflicts, xApps target different RAN control parameters (i.e., they do not conflict directly) but there may be some known or unknown coupling/dependence between them (see clause 4.2.1 in Chapter 4). This dependence may be in terms of their KPIs (which may be overlapping or different) + +or the impacts of their actions on the overall RAN state, i.e., actions of one xApp may cause the RAN state to change in such a way that previous actions of another xApp are no longer optimal for this new RAN state. Unless such conflicts are resolved/managed, such dependencies can cause uncontrollable system oscillations and performance degradations. + +#### 5.1.3.2 Impacted Use-Cases + +It is likely that many use cases are impacted by indirect and/or implicit conflicts including the already specified use cases. An example is the change in handover boundary (by e.g., MRO) which shall have an impact on xApps implementing Energy Savings, Traffic Steering (TS), Load Balancing, and Coverage and Capacity (CCO) etc. functionality. + +#### 5.1.3.3 Considerations + +The following considerations should be kept in mind when providing solutions to this key issue: + +- 1- Detection may use E2AP and/or E2SM-specific information. +- 2- Detection of indirect and/or implicit conflicts may happen after further investigation of detected potential conflicts. +- 3- Conflicts may be detected pre-action (i.e., before RIC Control Request or RIC Subscription Request messages have been sent to the E2 Node) or post-action (i.e., after RIC Control Request or RIC Subscription Request messages have been sent to the E2 Node). +- 4- The same solution may work for both indirect and implicit conflicts. +- 5- Only “harmful” conflicts may be detected. This may be justified by the fact that many RAN KPIs are coupled with each other, and achieving an entirely conflict-free system may be impossible. In such cases, we can consider managing conflicts rather than removing them completely. +- 6- The detection of indirect and/or implicit conflicts between xApps may be significantly challenging and it may require state-of-art AI/ML methods. + +#### 5.1.3.4 Open issues + +Same as discussed in clause 5.1.2.4. + +## 5.2 Solutions + +### 5.2.1 Solution #1 E2AP level direct conflict detection by Near-RT RIC platform + +#### 5.2.1.1 Introduction + +Key issue #1 for Conflict Detection (clause 5.1.1) describes the need for potential *pre-action* conflict detection by the Near-RT RIC platform for the specific case where the ConMit functionality in the Near-RT RIC platform is restricted to using only E2AP level information. + +This solution assumes that only E2AP level information {E2 Node Id, RAN Function ID, RIC Action Type} may be used by the platform during the RICARCH [i.1] defined xApp initiated E2 Subscription procedure ([i.1] clause 9.3.2.1), E2 Control procedure ([i.1] clause 9.3.2.4) and E2 Guidance request/response + +procedure ([i.1] clause 9.3.3.1). any additional information contained within E2SM specific encoded IEs would be transparent to the Near-RT RIC Platform. + +#### 5.2.1.2 Functional Description + +The Conflict Mitigation functionality in the Near-RT RIC platform ([i.1] clause 6.2.3) is assumed to handle E2AP level information from a requesting xApp and may compare this with similar information obtained from other xApps from previous E2 Subscription, E2 Control and/or E2 Guidance requests. + +An “E2AP level” potential conflict would be detected when and if the xApp requests the same RIC Action Type (particularly for POLICY) from E2 Subscription Request or CONTROL from E2 Control Request, for the same RAN Function ID on the same E2 Node ID as was previously used by another xApp. + +#### 5.2.1.3 Procedures + +For the E2AP Level conflict detection process, RICARCH [i.1] clause 9.3.3.1 (E2 guidance request/response procedure) step 3 “Near-RT RIC platform processes request” and clause 9.3.3.5 (E2 Guidance modification procedure) step 1 “Near-RT RIC platform identifies affected xApps and performs conflict mitigation processing” covers the scope of this solution. + +#### 5.2.1.4 Evaluation + +This solution is, by itself, sub-optimal as E2AP level potential conflict detection would often generate false positive detections whenever multiple xApps attempt to use the same RIC Action Type (i.e. POLICY) but with different target services. + +Examples include: + +- For a RAN function defined using E2SM-RC [i.2] when the different xApps are requesting POLICY services using different RIC Style Types. In this case there would not be a direct conflict but this would require analysis at the E2SM level and not just the E2AP level. + +### 5.2.2 Solution #2 E2SM level direct conflict detection by Near-RT RIC platform + +#### 5.2.2.1 Introduction + +Key issue #1 for Conflict Detection (clause 5.1.1) describes the need for potential *pre-action* conflict detection by the Near-RT RIC platform for the specific case where the ConMit functionality in the Near-RT RIC Platform is able to use both E2AP and E2SM level information. + +Key issue #2 for Conflict Detection (clause 5.1.2) describes the possibility of “E2SM inspection may be performed by the platform”. + +This solution assumes that after E2AP level information {E2 Node Id, RAN Function ID, RIC Action Type} analysis the platform may then also perform E2SM level analysis during the RICARCH [i.1] defined xApp initiated E2 Subscription procedure ([i.1] clause 9.3.2.1), E2 Control procedure ([i.1] clause 9.3.2.4) and E2 Guidance request/response procedure ([i.1] clause 9.3.3.1). + +#### 5.2.2.2 Functional Description + +Solution #1 describes how the Near-RT RIC platform ([i.1] clause 6.2.3) would use E2AP level information from a requesting xApp and compare this with similar information obtained from other xApps from previous + +E2 Subscription, E2 Control and/or E2 Guidance requests. The result would be a “E2AP level” potential conflict detection. + +In this solution the Conflict Mitigation functionality in the Near-RT RIC platform may then inspect E2SM level information from both the requesting xApp and the previous requests selected using E2AP level detection to determine if a direct conflict is likely to exist. + +Examples include: + +- For a RAN function defined using E2SM-RC [i.2] when the different xApps are requesting POLICY services using the same RIC Style Type (i.e. Style 1 for Radio Bearer Control), same RIC Action ID (i.e. ID 2 for QoS flow mapping configuration). In this case there would be a significant chance that the request is in direct conflict with a previous request from another xApp and that a Conflict Avoidance mechanism would be required. + +#### 5.2.2.3 Procedures + +For the E2AP level conflict detection process, RICARCH [i.1] clause 9.3.3.1 (E2 guidance request/response procedure) step 3 “Near-RT RIC platform processes request” and clause 9.3.3.5 (E2 Guidance modification procedure) step 1 “Near-RT RIC platform identifies affected xApps and performs conflict mitigation processing” covers the scope of this solution. + +In this case the Near-RT RIC platform would process both E2AP and E2SM level information. + +#### 5.2.2.4 Evaluation + +This solution offers a sound solution for both E2AP and E2SM level direct conflict detection with a low chance of false positive detections. + +The solution does however suffer from the need to align Near-RT RIC platform support of each E2SM with the versions used by each xApp which may prove to be difficult. + +### 5.2.3 Solution #3 E2SM level direct conflict detection by xApps + +#### 5.2.3.1 Introduction + +Key issue #1 for Conflict Detection (clause 5.1.1) describes the need for potential *pre-action* conflict detection by the Near-RT RIC platform for the specific case where the ConMit functionality in the Near-RT RIC Platform is restricted to using only E2AP level information. + +Key issue #2 for Conflict Detection (clause 5.1.2) describes the possibility of “E2SM inspection may be performed by the platform or by the conflicting xApps through direct or indirect communication”. + +This solution assumes that after E2AP level information {E2 Node Id, RAN Function ID, RIC Action Type} analysis the platform may request that one or more xApps perform E2SM level analysis during the RICARCH [i.1] defined xApp initiated E2 Subscription procedure ([i.1] clause 9.3.2.1), E2 Control procedure ([i.1] clause 9.3.2.4) and E2 Guidance request/response procedure ([i.1] clause 9.3.3.1). + +#### 5.2.3.2 Functional Description + +Solution #1 for Conflict Detection describes how the Near-RT RIC platform ([i.1] clause 6.2.3) would use E2AP level information from a requesting xApp and compare this with similar information obtained from + +other xApps from previous E2 Subscription, E2 Control and/or E2 Guidance requests. The result would be a “E2AP level” potential conflict detection. + +In this solution the Conflict Mitigation functionality in the Near-RT RIC platform may then request both the requesting xApp and/or one or more of the previous xApp selected using E2AP level detection to then inspect the E2SM level information from the requesting xApp and the previous requests selected using E2AP level detection to determine if a direct conflict is likely to exist. + +Examples include: + +- For a RAN function defined using E2SM-RC [i.2] when the different xApps are requesting POLICY services using the same RIC Style Type (i.e. Style 1 for Radio Bearer Control), same RIC Action ID (i.e. ID 2 for QoS flow mapping configuration). In this case there would be a significant chance that the request is in direct conflict with a previous request from another xApp and that a Conflict Avoidance mechanism would be required. + +#### 5.2.3.3 Procedures + +For the E2AP level conflict detection process, RICARCH [i.1] clause 9.3.3.1 (E2 guidance request/response procedure) step 3 “Near-RT RIC platform processes request” and clause 9.3.3.5 (E2 Guidance modification procedure) step 1 “Near-RT RIC platform identifies affected xApps and performs conflict mitigation processing” only covers the E2AP level analysis described in this solution. These procedures would need to be modified to so that the Near-RT RIC platform may seek E2SM level analysis from one or more xApps. + +###### RICARCH 9.3.3 E2 Guidance related procedures + +##### RICARCH 9.3.3.1 E2 Guidance request/response procedure + +The purpose of the xApp initiated E2 Guidance request/response API procedure in the Near-RT RIC is to allow authorized xApp to obtain guidance from the Near-RT RIC platform (with the conflict mitigation functionality) prior to initiating an action. + +Guidance from Near-RT RIC platform may include: + +- Indication on whether or not the xApp proposed E2 Related API message or series of messages may result in a conflict with E2 related API messages from other xApps; +- Recommendations on how the proposed E2 Related message or series of messages should be modified to avoid conflict; +- Modification of previous guidance to other xApps and/or Near-RT RIC platform internal processes. + +This procedure is based on the following assumptions: + +- xApp may use E2 Related API to obtain guidance from Near-RT RIC platform to resolve potential conflicts prior to initiating a RIC function procedure; +- xApp may use Near-RT RIC platform response in a subsequent procedure (i.e., for a RIC Functional Procedure). + +This procedure is initiated by an xApp using **E2 Related API: E2 Guidance** request. The following outcomes are considered: + +- Near-RT RIC Platform provides guidance to requesting xApp using E2 Related API: E2 Guidance response; + +- Near-RT RIC Platform provides modified guidance to another xApp and/or its internal processes. + +| Use Case Stage | Evolution / Specification | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | xApp initiation of Conflict Mitigation guidance. | +| Actors and Roles | <ul style="list-style-type: none"> <li>• xApp: Originator of Conflict Mitigation guidance request;</li> <li>• Near-RT RIC platform, with the following functionalities: <ul style="list-style-type: none"> <li>– Database;</li> <li>– Conflict mitigation.</li> </ul> </li> </ul> | +| Assumptions | <ul style="list-style-type: none"> <li>• Near-RT RIC platform has access to sufficient information to both detect a potential conflict and take a decision on an optimal mitigation solution;</li> <li>• Near-RT RIC platform may initiate guidance towards other xApp as an optional addition response to Guidance Request.</li> </ul> | +| Pre-conditions | <ul style="list-style-type: none"> <li>• xApp has been authorized to request guidance from Near-RT RIC platform for conflict mitigation;</li> <li>• xApp has been assigned xApp ID.</li> </ul> | +| Begins when | xApp determines need to request guidance from Near-RT RIC platform for conflict mitigation. | +| Step 1 (M) | xApp sends <b>E2 Related API E2 Guidance</b> Request to Near-RT RIC platform. | +| Step 2 (M) | Near-RT RIC platform collects related information. | +| Step 3A (M) | (MODIFIED) Near-RT RIC platform performs conflict mitigation detection | +| Step 3b (O) | (NEW) Near-RT RIC platform requests identified xApps to perform conflict mitigation detection | +| Step 3c (O) | (NEW) Near-RT RIC platform performs conflict mitigation processing. | +| Step 4-5 (O) | Near-RT RIC platform may signal conflict and/or provide guidance to internal processes and/or other xApps (see clause 9.3.3.5). | +| Step 6 (M) | Near-RT RIC platform sends <b>E2 Related API E2 Guidance</b> response to xApp. | +| Ends with | xApp continues processing using guidance response. | + +``` + +@startuml +skin rose +skinparam ParticipantPadding 50 +skinparam BoxPadding 10 +skinparam lifelineStrategy solid + +box "Near-RT RIC" +Collections "Other xApp" as xApp +participant "xApp" as xApp2 +Participant plt as "Near-RT RIC platform" +end box + +xApp2 -> plt: 1: (E2 related API) E2 Guidance (Request) +plt -> plt: 2: Collect related information +plt -> plt: 3a: (MODIFIED)Conflict mitigation detection +Alt If platform has identified a potential conflict + plt-->xApp2: 3b. (NEW)Conflict mitigation detection + plt-->xApp: 3b. (NEW)Conflict mitigation detection +end +plt -> plt: 3c. (NEW)Conflict mitigation processing +plt --> plt: 4: Guidance to internal processes +xApp <-- plt: 5: (E2 related API) E2 Guidance (Modification) +plt -> xApp2: 6: (E2 related API) E2 Guidance (Response) +@enduml + +``` + +![Sequence diagram showing the xApp initiated E2 guidance request/response procedure. The diagram is set within a 'Near-RT RIC' container. It features three main actors: 'Other xApp', 'xApp', and 'Near-RT RIC platform'. The process begins with 'xApp' sending a request (1: (E2 related API) E2 Guidance (Request)) to the 'Near-RT RIC platform'. The platform then performs internal actions: '2: Collect related information', '3a: (MODIFIED)Conflict mitigation detection', and '3c: (NEW)Conflict mitigation processing'. An alternative path (alt) is shown for '[If platform has identified a potential conflict]', where the platform sends '3b. (NEW)Conflict mitigation detection' to both 'Other xApp' and 'xApp'. Following this, the platform sends '4: Guidance to internal processes'. Then, it sends a modification message (5: (E2 related API) E2 Guidance (Modification)) to 'Other xApp' and a response message (6: (E2 related API) E2 Guidance (Response)) to 'xApp'.](a2969a6f33ca6ff2faddd5878fc418ef_img.jpg) + +Sequence diagram showing the xApp initiated E2 guidance request/response procedure. The diagram is set within a 'Near-RT RIC' container. It features three main actors: 'Other xApp', 'xApp', and 'Near-RT RIC platform'. The process begins with 'xApp' sending a request (1: (E2 related API) E2 Guidance (Request)) to the 'Near-RT RIC platform'. The platform then performs internal actions: '2: Collect related information', '3a: (MODIFIED)Conflict mitigation detection', and '3c: (NEW)Conflict mitigation processing'. An alternative path (alt) is shown for '[If platform has identified a potential conflict]', where the platform sends '3b. (NEW)Conflict mitigation detection' to both 'Other xApp' and 'xApp'. Following this, the platform sends '4: Guidance to internal processes'. Then, it sends a modification message (5: (E2 related API) E2 Guidance (Modification)) to 'Other xApp' and a response message (6: (E2 related API) E2 Guidance (Response)) to 'xApp'. + +Figure 5.2-1: RICARCH Figure 9.3.3.1-1: xApp initiated E2 guidance request/response procedure + +##### RICARCH 9.3.3.5 E2 Guidance modification procedure + +The purpose of the E2 Guidance modification procedure is to allow Near-RT RIC platform to signal a modified guidance to the xApp, which can be triggered by the Near-RT RIC platform's internal process (e.g., xApp subscription management), or by a message from the other xApps or external interfaces. + +The guidance may also be used for Near-RT RIC platform internal purposes. + +| Use Case Stage | Evolution / Specification | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | Near-RT RIC platform indicates guidance to an xApp without request from the xApp. | +| Actors and Roles | <ul style="list-style-type: none"> <li>xApp</li> <li>Near-RT RIC platform, with the following functionalities: <ul style="list-style-type: none"> <li>Database</li> <li>Conflict mitigation</li> </ul> </li> <li>External entity (e.g., E2 Node)</li> </ul> | +| Assumptions | <ul style="list-style-type: none"> <li>Near-RT RIC platform is capable of collecting related information, and generating proper guidance for an xApp.</li> </ul> | +| Pre-conditions | <ul style="list-style-type: none"> <li>Message from xApp, message from external interfaces, or Near-RT RIC platform's internal process triggers conflict mitigation in Near-RT RIC platform.</li> </ul> | +| Step 1a (M) | (MODIFIED) Near-RT RIC platform identifies potentially affected xApps and performs conflict mitigation processing. | +| Step 1b (O) | (NEW) Near-RT RIC platform requests identified xApps to perform conflict mitigation detection | +| Step 1c (O) | (NEW) Near-RT RIC platform performs conflict mitigation processing. | +| Step 2 (O) | Near-RT RIC platform may provide guidance to the affected xApp using E2 Guidance modification message. | +| Step 3 (O) | Near-RT RIC platform may also use the guidance for internal purposes. | + +``` + +@startuml +skin rose +skinparam ParticipantPadding 50 +skinparam BoxPadding 10 +skinparam lifelineStrategy solid + +Box "Near-RT RIC" +Participant xApp +Collections "Other xApp(s)" as OtherxApp +Participant "Near-RT RIC platform" as plt +endbox +Collections "External entity (e.g. Non-RT RIC)" as Otherentity + +Alt message from other xApp(s) triggers conflict mitigation + OtherxApp -> plt: Message that may introduce conflict +Else message from external entity triggers conflict mitigation + Otherentity -> plt: Message that may introduce conflict +Else internal processing triggers conflict mitigation + plt -> plt: internal process that may introduce conflict +End + +plt -> plt: 1a. (MODIFIED) Conflict mitigation detection +Alt If platform has identified a potential conflict + plt<-->xApp: 1b. (NEW) Conflict mitigation detection + plt<-->OtherxApp: 1b. (NEW) Conflict mitigation detection +end +plt -> plt: 1c. (NEW) Conflict mitigation processing +plt --> xApp: 2: E2 Guidance (Modification) +plt --> plt: 3: Guidance for internal purposes + +@enduml + +``` + +![Sequence diagram illustrating the E2 Guidance Modification Procedure. The diagram shows four lifelines: xApp, Other xApp(s), Near-RT RIC platform, and External entity (e.g. Non-RT RIC). The process starts with an 'alt' block where messages from Other xApp(s) or External entity trigger conflict mitigation, or internal processing triggers it. This leads to '1a. (MODIFIED) Conflict mitigation detection' on the platform. Another 'alt' block shows '1b. (NEW) Conflict mitigation detection' between the platform and xApp/Other xApp(s). This is followed by '1c. (NEW). Conflict mitigation processing' on the platform, then '2: E2 Guidance (Modification)' sent to xApp, and finally '3: Guidance for internal purposes' on the platform.](3b5a689f132b8f48289c3bf846ffbb98_img.jpg) + +``` + +sequenceDiagram + participant xApp + participant OtherxApp as Other xApp(s) + participant plt as Near-RT RIC platform + participant Otherentity as External entity (e.g. Non-RT RIC) + + alt [message from other xApp(s) triggers conflict mitigation] + OtherxApp->>plt: Message that may introduce conflict + else [message from external entity triggers conflict mitigation] + Otherentity->>plt: Message that may introduce conflict + else [internal processing triggers conflict mitigation] + plt->>plt: internal process that may introduce conflict + end + + plt->>plt: 1a. (MODIFIED) Conflict mitigation detection + + alt [If platform has identified a potential conflict] + plt<-->xApp: 1b. (NEW) Conflict mitigation detection + plt<-->OtherxApp: 1b. (NEW) Conflict mitigation detection + end + + plt->>plt: 1c. (NEW). Conflict mitigation processing + plt-->xApp: 2: E2 Guidance (Modification) + plt->>plt: 3: Guidance for internal purposes + +``` + +Sequence diagram illustrating the E2 Guidance Modification Procedure. The diagram shows four lifelines: xApp, Other xApp(s), Near-RT RIC platform, and External entity (e.g. Non-RT RIC). The process starts with an 'alt' block where messages from Other xApp(s) or External entity trigger conflict mitigation, or internal processing triggers it. This leads to '1a. (MODIFIED) Conflict mitigation detection' on the platform. Another 'alt' block shows '1b. (NEW) Conflict mitigation detection' between the platform and xApp/Other xApp(s). This is followed by '1c. (NEW). Conflict mitigation processing' on the platform, then '2: E2 Guidance (Modification)' sent to xApp, and finally '3: Guidance for internal purposes' on the platform. + +**Figure 5.2-2: RICARCH Figure 9.3.3.5-1 E2 Guidance Modification Procedure** + +#### 5.2.3.4 Evaluation + +This solution offers a sound solution for both E2AP and E2SM level direct conflict detection with a low chance of false positive detections. + +The solution avoids the need to align Near-RT RIC platform support of each E2SM with the versions used by each xApp. It does however rely on xApps supporting the appropriate E2SM versions. + +### 5.2.4 Solution #4 Post-Action Detection of E2-related Indirect and/or Implicit Conflicts + +#### 5.2.4.1 Introduction + +Key issue #1 for Conflict Detection (clause 5.1.1) describes the need for potential *pre-action* conflict detection by the Near-RT RIC platform for the specific case where the ConMit functionality in the Near-RT RIC platform may use both E2AP and E2SM level information. + +Key issue#3 for Conflict detection (clause 5.1.3) describes the possibility that detection of indirect and/or implicit conflicts may happen after further investigation of detected potential conflicts. However, an E2AP level conflict may not be confirmed at E2SM level *pre-action*. This may happen especially in case of indirect or implicit conflicts (see clause 4.2.1 and Key issue #3 in clause 5.1.3). Such conflicts are difficult to detect because in general xApp objectives based on some RAN KPIs are often “coupled” and complete decoupling may be impossible to obtain. The platform, therefore, may decide to allow the xApps to perform their respective policy or control actions on the E2 Node for as long as certain KPIs are not affected beyond an unacceptable level *post-action*. This means that, in such cases, the further investigation mentioned above (after detection of a potential conflict) must wait until after the affects of xApps’ actions are observable in the E2 Node. See clause 5.1.1.3 for considerations regarding indirect/implicit conflicts. + +The proposed solution (detailed in clauses 5.2.4.2 and 5.2.4.3) involves monitoring and detection of indirect and/or implicit conflicts post-action (as considered in clause 5.1.1.3) after obtaining some conflict relevant information from the xApps and observing RAN performance metrics relevant to the xApps’ objectives. The analysis happens in a limited context which is constructed from the information obtained from xApps’ subscription(s) (e.g., E2 Node, RAN Function, timing of associated RIC actions etc.) and the specific information provided by the xApps. + +NOTE: Since the platform may not be provisioned to handle E2SM information, the solution proposes two alternatives for E2SM processing. In implementation option 1, the ConMit functionality in the platform handles E2SM processing. In implementation option 2, a ConMit helper xApp handles E2SM processing and subscribes to the E2 Node to collect required information. + +#### 5.2.4.2 Functional Description + +The solution assumes the following prerequisites for the required conflict context: + +- A potential conflict between xApps has been previously detected pre-action involving an E2 Node. For example, two xApps have taken policy or control related actions at the same E2 Node. +- The potentially conflicting xApps have been identified. +- A direct conflict has not been confirmed at the E2SM level pre-action. This analysis/inspection, however, may result in E2SM knowledge specific to potentially conflicting xApps, e.g., any RAN parameters contained in xApp’s subscription. + +Overall Description: Post-action Conflict monitoring may be triggered by a request from an xApp, which is aware of a potential post-action conflict, and it has detected abnormalities/oscillations in its KPI(s). The solution proposes that the identified xApps provide the platform a set of RAN KPIs to be monitored. An xApp may provide the platform optional additional information such as, latest monitored values of these KPIs, the minimum acceptable values of these KPIs, and relevant RAN control parameters (NOTE: relevant control parameters may already be known to the platform during the prerequisite steps). The set of KPIs (per xApp) represents those E2SM defined KPIs in the E2 Node that the xApps consider to be important in terms of their own performance goals. If the provided information is insufficient to detect conflicts (e.g., if latest KPI values are not available), then ConMit must obtain the required data from the RAN E2 Node. After obtaining KPI data and other information, the ConMit service can monitor for any interdependence between xApp actions post-action using all the available information. + +As an example, consider 2 xApps that request the platform to monitor two KPIs and they may provide some additional optional information as mentioned above. The solution can be extended to any number of xApps. KPI1 is identified by xApp1 and KPI2 is identified by xApp2. By monitoring the relative changes in the two KPIs, the E2AP and E2SM level subscription information (obtained from previous conflict mitigation processing mentioned in the assumptions above), and the additional optional information provided by the xApps, the platform may detect a certain “harmful interdependence” between the two xApps. The platform may use advance AI/ML methods or some other algorithms to perform this task. For example, if KPI1 degrades beyond a certain performance minimum in correlation with KPI2, this indicates a harmful coupling between the two xApps, i.e., a post-action indirect/implicit conflict has been detected. Another possibility is that, if KPI1 and KPI2 are the same, actions of the two xApps may cause oscillations as they change different RAN parameter values according to different objectives (see clause 4.2). The platform may use side-information to further enhance this detection (such as any faults reported by the E2 Node) to isolate the degradation cause as: *a (possibly abnormal) degradation/oscillation caused by a conflict between xApps’ E2 related actions*. The exact solution for this analysis is left for implementation. + +NOTE: The list of potentially affected KPIs, which the platform obtains from the xApps, is the minimum information required for effective indirect conflict detection. However, even if the platform does not obtain added information from the xApps describing the unacceptable level of degradation or related RAN parameters, the platform may still detect abnormalities and dependence in KPIs. + +As such, the solution consists of the following steps: + +- Initialization: Trigger to monitor and detect indirect and/or implicit conflicts between certain xApps post-action. This part may be labelled as conflict mitigation related pre-processing as in E2 Guidance API description in [1.1]. The platform may decide on its own to monitor for conflicts. Alternatively, the trigger may come from an xApp as mentioned above. At this point, it is assumed that, due to the earlier potential conflict detection, the platform is already aware of potentially conflicting xApps (i.e., which xApps are acting on the RAN Node in question). If there are no such other xApps, the platform may inform the requesting xApps of the same immediately. +- E2 Guidance: A list of E2SM defined KPIs provided by xApps to be monitored for post-action conflicts along with optional additional information that may support the platform to detect unacceptable/abnormal degradation and inter-dependence in xApp actions. +- Conflict Context: The ConMit functionality or a helper ConMit xApp constructs the conflict context containing identification of the E2 Node, the RAN Function, and KPIs to be monitored etc. The E2AP information is assumed to be available at this point because of the earlier potential conflict detection. + +- E2SM reporting & Monitoring: If required, the ConMit functionality or a helper ConMit xApp subscribes to the E2 Node for data collection in the limited conflict context. Post-action KPI monitoring is performed by the platform either directly or by a ConMit helper xApp. +- Data analysis: Processing for conflict detection performed by either the platform itself or by the ConMit helper xApp. This processing is left for implementation. +- E2 Guidance: Reporting of the detected conflict (or absence thereof) to the xApps by the platform contains the affected KPIs and, optionally, potentially conflicting RAN parameters of this xApp etc. NOTE: This information may then be used for subsequent conflict resolution and avoidance. + +#### 5.2.4.3 Procedures + +##### 5.2.4.3.1 Implementation 1 (Platform handles E2SM): + +| Use Case Step | Description of the Step | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | ConMit functionality wants to resolve indirect and/or implicit conflicts at E2SM level among xApps | +| Actors and Roles | ConMit functionality<br>xApps<br>E2 Node | +| Assumptions | There are at least 2 xApps, 1 ConMit functionality, and 1 E2 Node available.<br>The ConMit functionality understand E2SM information and it is provisioned to handle such information. | +| Pre-conditions | ConMit functionality is authorized to resolve conflicts among xApps.<br>An E2AP level potential conflict is detected but has not been confirmed previously at E2SM level. xApps have been identified and informed about a potential conflict post-action. The necessary information regarding the E2 Node and the RAN Function is available. Additional optional side-information may also be available such as which RAN parameters may be involved in the conflict.<br>ConMit may request xApps for information which is required to detect the conflict post-action. | +| Begins when | Conflict detection trigger: Either an xApp requests the platform to detect a conflict with atleast one other xApp post action, or the platform's ConMit functionality triggers the process. | +| Step 0 (O) | a) An xApp reports a potential performance related conflict to the ConMit functionality.<br>b) The platform informs the xApp if there is a possible conflict that it can investigate. | +| Step 1 (M) | The ConMit requests xApps for the conflict relevant information | +| Step 2 (M) | a) The xApps prepare the conflict relevant information which contains the potentially affected KPIs and additional optional information such as degradation tolerance and RAN control parameters used in xApp's RIC control or policy actions.<br>b) The xApps send conflict relevant information to ConMit functionality and request conflict detection based on this information. | +| Step 3 (M) | The ConMit functionality responds with an Acknowledgment of conflict detection request based on the provided information. | +| Step 4 (M) | The ConMit functionality constructs the conflict context | + +| | | +|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Step 5 (M) | Data analysis is performed by the ConMit functionality, and it is determined if the information is sufficient for conflict determination | +| Step 6 (O) | If step 5 results in a conflict determination, conflict report is sent to the xApps and the platform records the detected conflict for future use in conflict avoidance and resolution | +| Step 7 (M) | If data collection from RAN is required, the ConMit functionality subscribes to the E2 Node for information reporting in the conflict context | +| Step 8 (M) | The E2 Node does information reporting | +| Step 9 (M) | Data analysis is performed by the ConMit functionality | +| Step 10 (O) | Conflict report is sent to the xApps and ConMit records the detected conflict for future use in conflict avoidance and resolution | +| Ends when | A conflict or lack thereof is determined | +| Exceptions | N/A | +| Post conditions | N/A | + +``` + +@startuml +skin rose +skinparam ParticipantPadding 4 +skinparam BoxPadding 4 +skinparam lifelineStrategy solid +skinparam defaultFontSize 12 + +participant xApp1 as xApp1 +participant xApp2 as xApp2 +Participant plt as "Near-RT RIC platform" +participant e2node as "E2 Node" + +plt -> plt: (Pre-action) Potential Conflict Detection + +Alt (Pre-action) E2SM level Potential conflict detection +xApp1<-->plt: Conflict Detection +xApp2<-->plt: Conflict Detection +end + +Alt (Post-action) If xApp detects oscillation due to a potential conflict +xApp1-->plt: 0a: (E2 Related API) E2 Guidance ((NEW) Conflict Check (Request)) +plt-->xApp1: 0b: (E2 Related API) E2 Guidance ((NEW) Conflict Check (Response)) +end + +plt -> plt: (Post-action) Conflict Detection (Trigger) + +plt -> xApp1: 1: (E2 related API) E2 Guidance (Modification, potential conflict information) +plt -> xApp2: 1: (E2 related API) E2 Guidance (Modification, potential conflict information) +xApp2 -> xApp2: 2a: (Modified) Prepare the conflict relevant information +xApp1 -> xApp1: 2a: (Modified) Prepare the conflict relevant information +xApp1 -> plt: 2b: (E2 related API) E2 Guidance (Request, conflict relevant information) +xApp2 -> plt: 2b: (E2 related API) E2 Guidance (Request, conflict relevant information) + +plt -> xApp1: 3a: (E2 related API) E2 Guidance (Reponse, Acknowledge) +plt -> xApp2: 3a: (E2 related API) E2 Guidance (Response, Acknowledge) + +plt -> plt: 4: (NEW) Compute conflict context + +``` + +``` + +Alt If sufficient Information for detection +plt -> plt: 5: (Modified) Conflict Mitigation (Data analysis) +plt --> xApp1: 6: (E2 related API) E2 Guidance (Modification, conflict report) +plt --> xApp2: 6: (E2 related API) E2 Guidance (Modification, conflict report) +plt --> plt: Record conflict + +else If data collection from RAN required +plt <-> e2node: 7: (E2) RIC Subscription (Report) + +Alt While Subscription Active +e2node -> plt: 8: (E2) RIC Indication (Report) +plt -> plt: 9: (Modified) Conflict Mitigation (Data analysis) +Alt Detection Complete +plt --> xApp1: 10: (E2 related API) E2 Guidance (Modification, conflict report) +plt --> xApp2: 10: (E2 related API) E2 Guidance (Modification, conflict report) +plt --> plt: Record conflict +end +end +end +@enduml + +``` + +![Sequence diagram for Implementation Option 1 (Platform Handles E2SM) showing interactions between xApp1, xApp2, Near-RT RIC platform, and E2 Node.](31f141cb102bc2873bc22577f8ff1a8b_img.jpg) + +``` + +sequenceDiagram + participant xApp1 + participant xApp2 + participant Near-RT RIC platform + participant E2 Node + + alt "[(Pre-action) E2SM level Potential conflict detection]" + xApp1->>Near-RT RIC platform: Conflict Detection + xApp2->>Near-RT RIC platform: Conflict Detection + end + + alt "[(Post-action) If xApp detects oscillation due to a potential conflict]" + xApp1->>Near-RT RIC platform: 0a: (E2 Related API) E2 Guidance ((NEW) Conflict Check (Request)) + Near-RT RIC platform-->>xApp1: 0b: (E2 Related API) E2 Guidance ((NEW) Conflict Check (Response)) + end + + Note over Near-RT RIC platform: (Post-action) Conflict Detection (Trigger) + + xApp1->>Near-RT RIC platform: 1: (E2 related API) E2 Guidance (Modification, potential conflict information) + xApp2->>Near-RT RIC platform: 1: (E2 related API) E2 Guidance (Modification, potential conflict information) + xApp2->>Near-RT RIC platform: 2a: (Modified) Prepare the conflict relevant information + xApp1->>Near-RT RIC platform: 2a: (Modified) Prepare the conflict relevant information + xApp2->>Near-RT RIC platform: 2b: (E2 related API) E2 Guidance (Request, conflict relevant information) + xApp1->>Near-RT RIC platform: 2b: (E2 related API) E2 Guidance (Request, conflict relevant information) + xApp2->>Near-RT RIC platform: 3a: (E2 related API) E2 Guidance (Response, Acknowledge) + xApp1->>Near-RT RIC platform: 3a: (E2 related API) E2 Guidance (Response, Acknowledge) + Note over Near-RT RIC platform: 4: (NEW) Compute conflict context + + alt "If sufficient Information for detection" + xApp1->>Near-RT RIC platform: 6: (E2 related API) E2 Guidance (Modification, conflict report) + xApp2->>Near-RT RIC platform: 6: (E2 related API) E2 Guidance (Modification, conflict report) + Note over Near-RT RIC platform: Record conflict + else "If data collection from RAN required" + xApp2->>E2 Node: 7: (E2) RIC Subscription (Report) + end + + alt "While Subscription Active" + E2 Node->>Near-RT RIC platform: 8: (E2) RIC Indication (Report) + Note over Near-RT RIC platform: 9: (Modified) Conflict Mitigation (Data analysis) + end + + alt "Detection Complete" + xApp1->>Near-RT RIC platform: 10: (E2 related API) E2 Guidance (Modification, conflict report) + xApp2->>Near-RT RIC platform: 10: (E2 related API) E2 Guidance (Modification, conflict report) + Note over Near-RT RIC platform: Record conflict + end + +``` + +Sequence diagram for Implementation Option 1 (Platform Handles E2SM) showing interactions between xApp1, xApp2, Near-RT RIC platform, and E2 Node. + +Figure 5.2-3: Implementation Option 1 (Platform Handles E2SM) + +##### 5.2.4.3.2 Implementation 2 (Platform does not handle E2SM): + +| Use Case Step | Description of the Step | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | ConMit functionality wants to resolve indirect and/or implicit conflicts at E2SM level among xApps | +| Actors and Roles | ConMit functionality<br>xApps<br>ConMit helper xApp | +| Assumptions | There are at least 2 xApps, 1 ConMit platform functionality, and 1 ConMit helper xApp.<br>The ConMit functionality does not understand E2SM information and/or it is not provisioned to handle such information. | +| Pre-conditions | ConMit functionality is authorized to resolve conflicts among xApps.<br><br>An E2AP level potential conflict is detected but has not been confirmed previously at E2SM level. xApps have been identified and informed about a potential conflict post-action. The necessary information regarding the E2 Node and the RAN Function is available. Additional optional side-information may also be available.<br><br>ConMit may request xApps for information which is required to detect the conflict post-action. | +| Begins when | Conflict detection trigger: Either an xApp requests the platform to detect a conflict with atleast one other xApp post action, or the platform's ConMit functionality triggers the process. | +| Step 0 (O) | a) An xApp reports a potential performance related conflict to the ConMit functionality.<br>b) The platform informs the xApp if there is a possible conflict that it can investigate. | +| Step 1 (M) | The ConMit requests xApps for the conflict relevant information | +| Step 2 (M) | a) The xApps prepare the conflict relevant information which contains the potentially affected KPIs and additional optional information such as degradation tolerance and RAN control parameters used in xApp's RIC control or policy actions.<br>b) The xApps send conflict relevant information to ConMit functionality and request conflict detection based on this information. | +| Step 3 (M) | a) The ConMit functionality responds with an Acknowledgment of conflict detection request based on the provided information.<br>b) The ConMit functionality, after obtaining information from the xApps, forwards this information to the helper xApp, provides associated E2AP level information, and requests a post-action conflict check | +| Step 4 (M) | The ConMit helper xApp constructs the conflict context. | +| Step 5 (M) | Data analysis is performed by the ConMit functionality, and it is determined if the information is sufficient for conflict determination | +| Step 6 (M) | If step 5 results in some determination, a conflict report is sent to the ConMit functionality by ConMit helper xApp. | +| Step 7 (O) | If step 5 results in some determination, conflict report is sent to the xApps and the platform records the detected conflict for future use in conflict avoidance and resolution. | +| Step 8 (M) | If data collection from RAN is required, ConMit helper xApp subscribes to the E2 Node for information reporting in the conflict context. | +| Step 9 (M) | The E2 Node does information reporting. | +| Step 10 (M) | Data analysis is performed by the ConMit helper xApp. | + +| | | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------| +| Step 11 (M) | Conflict report is sent to the ConMit functionality by ConMit helper xApp. | +| Step 12 (O) | Conflict report is sent to the xApps and ConMit records the detected conflict for future use in conflict avoidance and resolution | +| Ends when | A conflict or lack thereof is determined | +| Exceptions | N/A | +| Post conditions | N/A | + +``` + +@startuml +skin rose +skinparam ParticipantPadding 4 +skinparam BoxPadding 4 +skinparam lifelineStrategy solid +skinparam defaultFontSize 12 +participant xApp1 as xApp1 +participant xApp2 as xApp2 +Participant plt as "Near-RT RIC platform" +Participant xApph as "Helper xApp" +participant e2node as "E2 Node" + +plt -> plt: (Pre-action) Potential Conflict Detection + +Alt (Pre-action) E2SM level Potential Conflict Detection +xApp1<->plt: Conflict Detection +xApp2<->plt: Conflict Detection +end + +Alt (Post-action) If xApp detects oscillation due to a potential conflict +xApp1-->plt: 0a: (E2 Related API) E2 Guidance((NEW) Conflict Check (Request)) +plt-->xApp1: 0b: (E2 Related API) E2 Guidance ((NEW) Conflict Check (Response)) +end + +plt -> plt: (Post-action) Conflict Detection (Trigger) + +plt -> xApp1: 1: (E2 related API) E2 Guidance (Modification, potential conflict information) +plt -> xApp2: 1: (E2 related API) E2 Guidance (Modification, potential conflict information) + +xApp2 -> xApp2: 2a: (Modified) Prepare the conflict relevant information +xApp1 -> xApp1: 2a: (Modified) Prepare the conflict relevant information +xApp1 -> plt: 2b: (E2 related API) E2 Guidance (Request, conflict relevant information) +xApp2 -> plt: 2b: (E2 related API) E2 Guidance (Request, conflict relevant information) + +plt -> xApp1: 3a: (E2 related API) E2 Guidance (Reponse, Acknowledge) +plt -> xApp2: 3a: (E2 related API) E2 Guidance (Response, Acknowledge) +plt ->xApph: 3b: (NEW) conflict check (E2AP and conflict relevant informations) + +xApph -> xApph: 4: (NEW) Compute conflict context +Alt If sufficient Information for detection +xApph -> xApph: 5: (Modified) Conflict Mitigation (Data analysis) +xApph -> plt: 6: (NEW) conflict check (conflict report) +plt --> xApp1: 7: (E2 related API) E2 Guidance (Modification, conflict report) +plt --> xApp2: 7: (E2 related API) E2 Guidance (Modification, conflict report) +plt --> plt: Record conflict + +else If data collection from RAN required +plt <-> xApph: 8: (E2 related API) E2 Subscription (Report) +plt <-> e2node: 8: (E2) RIC Subscription (Report) + +Alt While Subscription Active + +``` + +``` + +e2node -> plt: 9: (E2) RIC Indication (Report) +plt -> xApph: 9: (E2 related API) E2 Indication (Report) +xApph -> xApph: 10: (NEW) Conflict Mitigation (Data analysis) + +``` + +``` + +Alt Detection Complete +xApph -> plt: 11: (NEW) conflict check (conflict report) +plt --> xApp1: 12: (E2 related API) E2 Guidance (Modification, conflict report) +plt --> xApp2: 12: (E2 related API) E2 Guidance (Modification, conflict report) +plt --> plt: Record conflict +end +end +end +@enduml + +``` + +![Sequence diagram for Implementation Option 2 (Helper xApp Handles E2SM). The diagram shows interactions between xApp1, xApp2, Near-RT RIC platform, Helper xApp, and E2 Node. Key steps include: (Pre-action) Potential Conflict Detection, (Post-action) Conflict Detection (Trigger), (E2 related API) E2 Guidance (Modification, potential conflict information), (E2 related API) E2 Guidance (Request, conflict relevant information), (E2 related API) E2 Guidance (Response, Acknowledge), (NEW) conflict check (E2AP and conflict relevant informations), (NEW) Compute conflict context, (Modified) Conflict Mitigation (Data analysis), (E2 related API) E2 Guidance (Modification, conflict report), (E2 related API) E2 Subscription (Report), (E2) RIC Subscription (Report), (E2) RIC Indication (Report), (NEW) Conflict Mitigation (Data analysis), (NEW) conflict check (conflict report), and (E2 related API) E2 Guidance (Modification, conflict report).](d8c8ad20c2d438a0c8211457311b4fd4_img.jpg) + +Sequence diagram for Implementation Option 2 (Helper xApp Handles E2SM). The diagram shows interactions between xApp1, xApp2, Near-RT RIC platform, Helper xApp, and E2 Node. Key steps include: (Pre-action) Potential Conflict Detection, (Post-action) Conflict Detection (Trigger), (E2 related API) E2 Guidance (Modification, potential conflict information), (E2 related API) E2 Guidance (Request, conflict relevant information), (E2 related API) E2 Guidance (Response, Acknowledge), (NEW) conflict check (E2AP and conflict relevant informations), (NEW) Compute conflict context, (Modified) Conflict Mitigation (Data analysis), (E2 related API) E2 Guidance (Modification, conflict report), (E2 related API) E2 Subscription (Report), (E2) RIC Subscription (Report), (E2) RIC Indication (Report), (NEW) Conflict Mitigation (Data analysis), (NEW) conflict check (conflict report), and (E2 related API) E2 Guidance (Modification, conflict report). + +Figure 5.2-4: Implementation Option 2 (Helper xApp Handles E2SM) + +#### 5.2.4.4 Evaluation + +The solution addresses the considerations in clause 5.1.1.3 in the following ways: + +- The solution requires both E2AP and E2SM level information. +- The solution assumes that the platform and xApps are aware of a previously detected potential conflict which was not confirmed (pre-action) using E2AP and E2SM information. So further post-action investigation is required to detect any indirect/implicit conflicts. +- The solution proposes to detect indirect/implicit conflicts post-action. It is assumed that these conflicts are either not detected pre-action or they only arise post-action for certain RAN states. + +- Only “harmful” conflicts may be detected. This may be justified by the fact that many RAN KPIs are coupled with each other, and achieving an entirely conflict-free system may be impossible. In such cases, we can consider managing conflicts rather than removing them completely. +- Same solution works for both indirect and/or implicit conflicts. + +The solution addresses the open issues in clause 5.1.1.4 in the following ways: + +- The solution does not require direct xApp communication for conflict detection. The E2SM inspection is done by the platform or a helper xApp. +- If the platform is not provisioned to handle E2SM information, then a helper xApp is deployed for this purpose. The xApps are not required to expose their business-logic. For example, the xApps may not expose changes made to the RAN parameters. The KPIs they expose/provide for conflict monitoring are standardized KPIs. + +The solution requires tools for intelligent analysis of E2AP and E2SM specific data (e.g., the required correlation analysis or AI/ML methods) to be either part of the Near-RT RIC platform functionality or be provided as part of the helper xApp. + +### 5.2.5 Solution #5 Pre-Action Detection of E2-related Indirect Conflicts with user configured parameter dependency information + +#### 5.2.5.1 Introduction + +Key issue#3 for Conflict detection (clause 5.1.3) describes the possibility that indirect conflicts may be detected pre-action, i.e., before RIC CONTROL REQUEST or RIC SUBSCRIPTION REQUEST messages have been sent to the E2 Node. + +NOTE: As mentioned in clause 5.1.3.1, when xApps target different RAN control parameters, there can be conflicting impacts of their actions on the overall RAN state. This solution considers such scenarios as indirect conflicts, which do not need any KPIs to be monitored to detect the conflict. + +The proposed solution (detailed in clauses 5.2.5.2 and 5.2.5.3) focuses on detecting the indirect conflicts pre-action (i.e. before RIC CONTROL REQUEST or RIC SUBSCRIPTION REQUEST messages have been sent to the E2 nodes) based on the parameter dependency information provided by the user as an input to the ConMit functionality or a helper ConMit xApp. + +This solution assumes that after E2AP level information {E2 Node Id, RAN Function ID, RIC Action Type} analysis the ConMit Functionality or ConMit helper xApp also performs E2SM level analysis during the RICARCH [i.1] defined xApp initiated E2 Subscription procedure ([i.1] clause 9.3.2.1), E2 Control procedure ([i.1] clause 9.3.2.4) and E2 Guidance request/response procedure ([i.1] clause 9.3.3.1). + +NOTE: Since the platform may not be provisioned to handle E2SM information, the solution proposes two alternatives for E2SM processing. In implementation option 1, the ConMit functionality in the platform handles E2SM processing. In implementation option 2, a ConMit helper xApp handles E2SM processing and subscribes to the E2 Node to collect required information. + +#### 5.2.5.2 Functional Description + +The solution assumes the following prerequisites: + +- Parameter dependency information is provided to the ConMit functionality or ConMit helper xApp as an input. + +- This information can be in the form of a linear lookup table or a dependency graph or any other preferred format, which captures the relationship between the RAN parameters in RIC CONTROL/POLICY service and their probable impact on a set of KPIs (see clause 4.2.1). This information can be continuously improved as and when new conflicts are discovered. +- A human user can prepare this dependency information. Potentially the dependency information can be prepared and continuously improved by an AI/ML system. + +Overall Description: Before the xApps are onboarded and put in operation, a user can analyze and predict the inter-dependencies among the RAN parameters changed by the xApps. The user provided parameter dependency information maps the RIC CONTROL/POLICY parameters to a common system impact. If the ConMit functionality or a helper ConMit xApp has inter-parameter dependencies and predicted system impacts for certain parameters, then it can detect indirect conflict after investigating E2SM and E2AP information from the xApp procedures, whenever these parameters are involved. As more conflicts between parameters are learned/discovered, the user can update the knowledge base. + +ConMit functionality or a helper ConMit xApp uses this mapping to declare that RIC CONTROL/POLICY parameters changed by two or more xApps are in indirect conflict. Since the detection of potential conflict takes place before the RIC CONTROL REQUEST or RIC SUBSCRIPTION REQUEST is applied to the E2 nodes, this is a pre-action detection. The solution can be extended to detecting any number of indirect co-existing conflicts across two or more xApps. For example, let us assume two xApps changing two different RAN parameters. xApp1 and xApp2 change RIC CONTROL/POLICY parameters C1 and C2 respectively. C1 and C2 are different parameters, hence there is no direct conflict. However, changes in C1 and C2 individually may lead to a common system impact resulting in indirect conflict. The user provided parameter dependency information maps the relationship between C1 and C2 to a common system impact. ConMit functionality or a helper ConMit xApp uses this mapping to declare that RIC CONTROL/POLICY parameters changed by xApp1 and xApp2 are in indirect conflict. + +As such, the solution consists of the following steps: + +- Before the xApps are put in operation, a user configures the parameter dependency information as input into the ConMit functionality or helper ConMit xApp. This dependency information is sent to the Near-RT RIC e.g. via O1 interface. +- xApps may send the changed parameters with E2AP and E2SM level details as part of E2 CONTROL REQUEST or E2 SUBSCRIPTION REQUEST or E2 GUIDANCE REQUEST to Near-RT RIC platform. These outputs do not need to be simultaneous to be considered as potential conflict. +- ConMit functionality or helper ConMit xApp checks the RAN parameters received from the xApps against the parameter dependency information. If the changed parameters by different xApps map to a common KPI impact, then the ConMit functionality or helper ConMit xApp declares it as a potential implicit conflict. +- The detected conflict (or absence thereof) is reported to the xApps by the Near-RT RIC platform. This report contains information on the impacted system functions, optionally, potential conflicting RAN parameters of the conflicting xApps, etc. +- In addition to the pre-action conflict detection based on the user provided parameter dependency information, the ConMit functionality or helper ConMit xApp can further leverage post-action detection where certain KPIs can be monitored after the changes from xApps are applied to the E2 nodes, to further detect unacceptable/abnormal degradation and inter-dependence in xApp actions that are not detected in the pre-action conflict detection stage. + +#### 5.2.5.3 Procedures + +Two or more xApps send the E2 CONTROL REQUEST or E2 SUBSCRIPTION REQUEST or E2 GUIDANCE REQUEST to the Near-RT RIC platform. The ConMit functionality or the helper xApp decodes both the E2AP and E2SM level details in these messages. With the use of the user-provided parameter dependency information, if the ConMit functionality or the helper xApp map the changed parameters to a common system impact, then an indirect conflict is detected. This conflict detection report with relevant information is sent to the involved xApps. + +#### 5.2.5.4 Evaluation + +### 5.2.6 Solution #6 Pre-Action Detection of Potential E2-related Implicit Conflicts with user configured parameter dependency information + +#### 5.2.6.1 Introduction + +Key issue #1 for Conflict Detection (clause 5.1.1) describes the need for potential *pre-action* conflict detection by the Near-RT RIC platform for the specific case where the ConMit functionality in the Near-RT RIC platform may use both E2AP and E2SM level information. + +NOTE: As mentioned in clause 5.1.3.1, when xApps target different RAN control parameters, there may be conflicting impacts of their actions in terms of KPIs. This solution considers such scenarios as implicit conflicts. + +The proposed solution (detailed in clauses 5.2.6.2 and 5.2.6.3) focuses on detecting the potential implicit conflicts pre-action (i.e. before RIC CONTROL REQUEST or RIC SUBSCRIPTION REQUEST messages have been sent to the E2 nodes) based on the parameter dependency information provided by the user as an input to the ConMit functionality or a helper ConMit xApp. + +This solution assumes that after E2AP level information {E2 Node Id, RAN Function ID, RIC Action Type} analysis, the ConMit functionality or ConMit helper xApp also performs E2SM level analysis during the RICARCH [i.1] defined xApp initiated E2 Subscription procedure ([i.1] clause 9.3.2.1), E2 Control procedure ([i.1] clause 9.3.2.4) and E2 Guidance request/response procedure ([i.1] clause 9.3.3.1). + +NOTE: Since the platform may not be provisioned to handle E2SM information, the solution proposes two alternatives for E2SM processing. In implementation option 1, the ConMit functionality in the platform handles E2SM processing. In implementation option 2, a ConMit helper xApp handles E2SM processing and subscribes to the E2 Node to collect required information. + +#### 5.2.6.2 Functional Description + +The solution assumes the following prerequisites: + +- Parameter dependency information is provided to the ConMit functionality or ConMit helper xApp as an input. +- This information can be in the form of a linear lookup table or a dependency graph or any other preferred format, which captures the relationship between the RAN parameters in RIC CONTROL/POLICY service and their probable impact on a set of KPIs (see clause 4.2.1). This information can be continuously improved as and when new conflicts are discovered. +- A human user can prepare this dependency information. Potentially the dependency information can be prepared and continuously improved by an AI/ML system. + +Overall Description: Before xApps are onboarded and put in operation, system/user can analyze and predict the inter-dependencies among the RAN parameters that may cause implicit KPI conflicts. The system/user provided parameter dependency information maps the RIC CONTROL/POLICY parameters to possible KPI impacts. If the ConMit functionality or a helper ConMit xApp has inter-parameter dependencies and possible KPI impacts for certain parameters, then it can detect potential implicit conflict after investigating E2SM and E2AP information from the xApp procedures, whenever these parameters are involved. As more conflicts between parameters are learned/discovered, the system/user can update the knowledge base. + +ConMit functionality or a helper ConMit xApp uses this mapping to declare that RIC CONTROL/POLICY parameters changed by two or more xApps are in potential implicit conflict if the changes done by xApps map to common KPI impact. Since the detection of potential conflict takes place before the RIC CONTROL REQUEST or RIC SUBSCRIPTION REQUEST is applied to the E2 nodes, this is a pre-action detection. The solution can be extended to detecting any number of indirect co-existing conflicts across two or more xApps. + +For example, let us assume an xApp, xApp1, changes RIC CONTROL/POLICY RAN parameter C1. The parameter dependency information is provided to ConMit functionality or a helper ConMit xApp by mapping C1 to KPI1 & KPI2 meaning changes in C1 can possibly impact KPI1 & KPI2. Then, another xApp, xApp 2, change another RAN parameter C2 which is marked having impact to KPI1 and KPI2 as well. The ConMit functionality or a helper ConMit xApp uses this mapping to declares that RIC CONTROL/POLICY parameters changed by xApp1 and xApp2 are in potential implicit conflict. The potential pre-action conflict is declared, and post-action conflict detection will be triggered by either the Near-RT RIC framework or the involved xApps. This solution can be extended by mapping multiple RIC CONTROL/POLICY parameters to multiple sets of KPIs with possible weightage. + +As such, the solution consists of the following steps: + +- Before the xApps are put in operation, a user configures the parameter dependency information as input into the ConMit functionality or helper ConMit xApp. This dependency information is sent to the Near-RT RIC e.g. via O1 interface. +- xApps may send the changed parameters with E2AP and E2SM level details as part of E2 CONTROL REQUEST or E2 SUBSCRIPTION REQUEST or E2 GUIDANCE REQUEST to Near-RT RIC platform. These outputs do not need to be simultaneous to be considered as potential conflict. +- ConMit functionality or helper ConMit xApp checks the RAN parameters received from the xApps against the parameter dependency information. If the changed parameters by different xApps map to a common KPI impact, then the ConMit functionality or helper ConMit xApp declares it as a potential implicit conflict. +- The detected conflict (or absence thereof) is reported to the xApps by the Near-RT RIC platform. This report contains information on the impacted system functions, optionally, potential conflicting RAN parameters of the conflicting xApps, etc. +- In addition to the pre-action conflict detection based on the user provided parameter dependency information, the ConMit functionality or helper ConMit xApp can further leverage post-action detection where certain KPIs can be monitored after the changes from xApps are applied to the E2 nodes, to further detect unacceptable/abnormal degradation and inter-dependence in xApp actions that are not detected in the pre-action conflict detection stage. + +#### 5.2.6.3 Procedures + +Two or more xApps send the E2 CONTROL REQUEST or E2 SUBSCRIPTION REQUEST or E2 GUIDANCE REQUEST to the Near-RT RIC platform. The ConMit functionality or the helper xApp decodes both the E2AP and E2SM level details in these messages. With the use of the user-provided parameter dependency information, if the ConMit functionality or the helper xApp map the changed parameters to a common KPI impact, then a potential implicit conflict is detected. This conflict detection report with relevant information is sent to the involved xApps. + +#### 5.2.6.4 Evaluation + +### 5.2.7 Solution #7 Pre-Action Detection of E2-related Implicit Conflicts with user configured parameter dependency information + +#### 5.2.7.1 Introduction + +Key issue#3 for Conflict detection (clause 5.1.3) describes the possibility that implicit conflicts may be detected in pre-action also, i.e., before RIC CONTROL REQUEST or RIC SUBSCRIPTION REQUEST messages have been sent to the E2 Node. + +NOTE: As mentioned in clause 5.1.3.1, when xApps target different RAN control parameters, there may be conflicting impacts of their actions in terms of KPIs. This solution considers such scenarios as implicit conflict + +The proposed solution (detailed in clauses 5.2.7.2 and 5.2.7.3) focuses on detecting the implicit conflicts pre-action including both potential conflicts and the actual conflicts. The solution is based on the parameter dependency information provided as an input to the ConMit functionality or a helper ConMit xApp which help to detect potential conflict pre-action. If a potential conflict is detected, ConMit functionality or a helper ConMit xApp invoke another algorithm (e.g. AI/ML or digital twin based) to predict the impacts on KPIs by changes done in the RAN parameters based on learning from historical data. This prediction can be performed by ConMit functionality or a helper ConMit xApp itself or by another service in Near-RT RIC or another xApp. Both the potential conflict detection and actual conflict detection through KPI impact prediction are done in pre-action stage before the RIC CONTROL REQUEST or RIC SUBSCRIPTION REQUEST messages have been sent to the E2 Node. + +NOTE: Since the platform may not be provisioned to handle E2SM information, the solution proposes two alternatives for E2SM processing. In implementation option 1, the ConMit functionality in the platform handles E2SM processing. In implementation option 2, a ConMit helper xApp handles E2SM processing and subscribes to the E2 Node to collect required information. + +#### 5.2.7.2 Functional Description + +The solution assumes the following prerequisites: + +- Parameter dependency information is provided to the ConMit functionality or ConMit helper xApp as an input. +- This information can be in the form of a linear lookup table or a dependency graph or any other preferred format, which captures the relationship between the RAN parameters in RIC CONTROL/POLICY service and their predicted impact on a set of KPIs (see clause 4.2.1) This information can be continuously improved as and when new conflicts are discovered. + +- A human user can prepare this dependency information. Potentially the dependency information can be prepared and continuously improved by an AI/ML system. + +Overall Description: Before certain xApps are onboarded and put in operation, system/user can analyze and predict the inter-dependencies among the RAN parameters that may cause implicit KPI conflicts. The system/user provided parameter dependency information maps the RIC CONTROL/POLICY parameters to a common KPI impact. If the ConMit functionality or a helper ConMit xApp has inter-parameter dependencies and predicted KPI impacts for certain parameters, then it can detect potential implicit conflict after investigating E2SM and E2AP information from the xApp procedures, whenever these parameters are involved. As more conflicts between parameters are learned/discovered, the system/user can update the knowledge base. + +The ConMit functionality or a helper ConMit xApp uses this mapping to declare that RIC CONTROL/POLICY parameters change by the xApps are in potential implicit conflict. After this pre-action potential implicit conflict detection, either the Near-RT RIC framework or the involved xApps invokes another algorithm to predict the impacts on KPIs by the changes done. + +For example, let us assume the prediction algorithm predicts that the change in RIC CONTROL/POLICY parameter C1 from xApp1 will degrade KPI1 and improve KPI2, however the changes from xApp2 on parameter C2 will not affect KPI1 but degrade KPI2. The ConMit functionality or a helper ConMit xApp immediately declare it as implicit conflict. Since the detection of potential conflict takes place before the RIC CONTROL REQUEST or RIC SUBSCRIPTION REQUEST is applied to the E2 nodes, this is a pre-action detection. The solution can be extended to any number of xApps. + +As such, the solution consists of the following steps: + +- Before the xApps are put in operation, a user configures the parameter dependency information as input into the ConMit functionality or helper ConMit xApp. This dependency information is sent to the Near-RT RIC e.g. via O1 interface. +- xApps may send the changed parameters with E2AP and E2SM level details as part of E2 CONTROL REQUEST or E2 SUBSCRIPTION REQUEST or E2 GUIDANCE REQUEST to Near-RT RIC platform. These outputs do not need to be simultaneous to be considered as potential conflict. +- ConMit functionality or helper ConMit xApp checks the RAN parameters received from the xApps against the parameter dependency information. If the changed parameters by different xApps map to the common KPI impacts, then the ConMit functionality or helper ConMit xApp declares it as potential implicit conflict. +- Another algorithm or AIML model is invoked by the ConMit functionality or helper ConMit xApp to predict the exact KPI impacts by the changed parameters. +- If a KPI impact conflict is detected through the prediction, the ConMit functionality or helper ConMit xApp report the detected conflict (or absence thereof) to the xApps. This report contains information on the impacted system functions, optionally, potential conflicting RAN parameters of the conflicting xApps, etc. + +NOTE: This information may then be used for subsequent conflict resolution and avoidance. + +#### 5.2.7.3 Procedures + +Two or more xApps send the E2 CONTROL REQUEST or E2 SUBSCRIPTION REQUEST or E2 GUIDANCE REQUEST to the Near-RT RIC platform. The ConMit functionality or the helper xApp decodes + +both the E2AP and E2SM level details in these messages. With the use of the user-provided parameter dependency information, if the ConMit functionality or the helper xApp map the changed parameters to a common KPI impact, then a potential implicit conflict is detected. Furthermore, with the use of another algorithm, if the ConMit functionality and the helper xApp predict the exact KPI impact, then actual implicit conflict is detected. This conflict detection report with relevant information is sent to the involved xApps. + +#### 5.2.7.4 Evaluation + +## 5.3 Solutions-to-Key Issues Mapping + +**Table 5.3-1: Solutions to Key Issue Mapping** + +| Solution | Key Issue | | | +|----------|-----------|-----|-----| +| | #1 | #2 | #3 | +| #1 | yes | | | +| #2 | | yes | | +| #3 | | yes | | +| #4 | | | yes | +| #5 | | | yes | +| #6 | yes | | | +| #7 | | | yes | + +# 6 Conflict Resolution + +## 6.1 Key Issues + +### 6.1.1 Key Issue #1 Resolution of E2-related Conflicts + +#### 6.1.1.1 Description + +This key issue addresses the problem of E2-related conflict resolution between xApps under the assumption that direct, indirect, or implicit conflicts have been detected and the conflicting xApps have been identified. + +The resolutions may comprise the following: + +- 1- xApps may reach a “resolution agreement” themselves directly or indirectly facilitated by conflict mitigation (ConMit) functionality in the platform. +- 2- ConMit may compute E2AP or E2SM level agreement for the xApps. This agreement is later enforced by ConMit. + +#### 6.1.1.2 Impacted Use-Cases + +void + +#### 6.1.1.3 Considerations + +Solutions for E2-related conflict resolution may consider the following: + +- 1- Resolution may take place both pre-action and post-action depending on when the conflict is detected. +- 2- A general solution may work for all conflict types or different solutions may be provided for different conflict types. For example, a solution may address direct conflicts but not indirect and/or implicit conflicts. +- 3- E2AP level agreements: For example, xApps may agree not to use certain RIC service types (control, policy etc.) for the same E2 Node and/or RAN Function. +- 4- E2SM level agreements: For example, xApps may agree not to access certain RAN parameter(s) or a similar agreement may be reached in case of RAN resource conflicts. +- 5- E2AP level guidance agreement: xApps may agree to access an E2 Node and/or RAN Function only after guidance by the platform. +- 6- E2SM level guidance agreement: xApps may agree to access certain RAN parameters or RAN resources only after guidance by the platform. +- 7- E2SM level negotiation: xApps may negotiate and reach an agreement on certain RAN Parameters, RAN KPIs, and/or RAN Resources. This may allow them to “manage” their conflicts. +- 8- Agreements may be recorded/saved for future conflict avoidance and/or during a new conflict resolution. + +#### 6.1.1.4 Open issues + +Following open issues are relevant: + +- 1- ConMit may facilitate inter-xApp resolution, but it may not be able to resolve conflicts by itself at E2SM level without xApp-specific E2SM information. + - a. Furthermore, xApps can, in principle, resolve their conflicts but this additional functionality must be part of their design. +- 2- Can ConMit force conflict resolution and an agreement, e.g., by occasionally denying E2 Subscription or E2 Control requests by xApps? +- 3- How to deal with failure of conflict resolution process between xApps? +- 4- Privacy: How to protect xApps’ business logic during resolution? + +## 6.2 Solutions + +### 6.2.1 Solution #1 Resolution of Direct Parameter Conflicts between xApps at E2SM level + +#### 6.2.1.1 Introduction + +A direct parameter conflict may occur between two or more xApps if they request access to the same set of RAN parameters in the same E2 Node. Some consideration for solutions to this type of conflicts are mentioned in clause 6.1.2.3. + +As mentioned in clause 6.1.2.3, one possible resolution may be to prioritize one xApp’s E2 Subscription among all others so that only the xApp that has the priority accesses the RAN function/service and changes + +the parameter. Note that, such a resolution requires an E2SM level agreement between the xApps. However, such resolutions may not always be possible, e.g., if the objectives of an xApp that is not able to make RAN parameter changes are compromised beyond an acceptable level. Also, this type of approach may lead to sub-optimal performance of the network. + +Another approach may be for xApps to directly negotiate and reach an E2SM level agreement over the values of a certain RAN parameter via inter-xApp communication. However, in a multi-vendor environment, when different xApps may be produced by different vendors, xApps may not reach such an agreement. As mentioned in clause 6.1.2.4, such direct inter-xApp functionality may not be supported for all xApps. Furthermore, for a large number of xApps, this may not be technically feasible within the Near-RT RIC control time-granularity. + +So, a solution is necessary to resolve direct parameter conflicts among xApps at E2SM level without requiring direct inter-xApp communication for negotiation. The proposed solution is “indirect” in the sense that the conflict mitigation functionality in the platform proposes a compromised/common value of the RAN parameter to the xApps (e.g., within an E2 Guidance Modification message [i.1]). The proposed solution, which can then be configured in the E2 Node, represents a value of the RAN parameter serving the common interests of the xApps. Such common value may be calculated in various ways as shown in the examples in clause 6.2.1.2. + +NOTE: The common value may be computed by the platform itself if it is capable of handling E2SM information. However, to address open issues 1 and 4 in key issue#1 clause 6.1.1.4, an option is to avoid processing E2SM specific information in the platform ConMit functionality directly. Instead, a “helper” ConMit xApp may be used for this purpose. The conflicting xApps send E2SM information to the platform which forwards the same to the helper xApp over the Near-RT RIC internal APIs. It is assumed that the helper xApp understands all E2SM specific information, but conflicting xApps’ business logic is not exposed to the helper xApp. After calculation of the common parameter, the helper xApp sends the results back to the platform which forwards them to the xApps. The same helper xApp may also be used to configure the common RAN parameter in the RAN on behalf of the xApps. Whether such an xApp and the required APIs are technically feasible is an important consideration. The same applies to privacy and security issues related to E2SM information exchanges. + +#### 6.2.1.2 Functional Description + +The solution assumes the following: + +- 1- A direct RAN parameter conflict has already been detected pre-action or post-action involving a particular RAN parameter and the conflicting xApps have already been identified. +- 2- An E2AP level resolution/agreement is not appropriate. +- 3- An E2SM level resolution has been triggered either by xApp(s) or by conflict mitigation inside the platform. +- 4- Near-RT RIC may configure the RAN parameter in the E2 Node after successful resolution. + +The xApps may communicate to the platform their preference regarding the RAN parameter. This preference is used to compute a common value for that parameter taking interests of all the xApps into account. Below we explain the solution with an example of a conflict between two xApps. The idea can be extended to any number of xApps. Below we provide two examples showing how the common value may be computed. + +##### 6.2.1.2.1 Example 1: Common Value Calculation Method 1 + +In this method, the xApps send their preferred values of the parameter and the common value is calculated by averaging those values. For example, let us assume that xApp<sub>1</sub> and xApp<sub>2</sub> want to access and change the same RAN parameter $p$ in the same E2 node. xApp<sub>1</sub> wants to set the value at $p_1$ while xApp<sub>2</sub> wants to set the value at $p_2$ . After both send this value, the common value is calculated as the average $p = p_c = (p_1 + p_2)/2$ . This solution is simple and fast, but not optimal. + +##### 6.2.1.2.2 Example 2: Preferred Common Value Calculation Method 2 + +In this method, instead of sending values of the parameter, the xApps send utility functions. A utility function maps the “goodness” of a parameter value to a predefined scale, e.g., [0:1] scale. So, when different xApps send their utility functions, the common resolved value of the parameter is the one for which the product of the utility functions is maximized. This is called *Nash Social Welfare Solution*. Note that the utility functions do not expose the business-logic of the xApps but rather their “interests”. + +#### 6.2.1.3 Procedures + +##### 6.2.1.3.1 Implementation 1 (Platform handles E2SM): + +| Use Case Step | Description of the Step | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | ConMit functionality wants to resolve direct parameter conflicts at E2SM level among xApps | +| Actors and Roles | ConMit functionality<br>xApps | +| Assumptions | There are at least 2 xApps and 1 ConMit functionality available. There is at least 1 conflicting RAN parameter.<br><br>The ConMit functionality understands E2SM specific information, or it uses a helper xApp to process such an information. | +| Pre-conditions | ConMit functionality is authorized to resolve conflicts among xApps.<br><br>ConMit may request xApps for information which is necessary to resolve the conflict. | +| Begins when | Conflict detection: A direct RAN parameter has been identified and the xApps have been identified to take part in conflict resolution at the E2SM level. | +| Step 1 (M) | The ConMit requests xApps to send their preference over the parameter. | +| Step 2 (M) | a) The xApps compute their preferences<br>b) The xApps send preferences to ConMit functionality. | +| Step 3 (M) | a) The ConMit functionality calculates the final common value of the parameter.<br>b) The ConMit functionality sends the computed value to the xApps. | +| Ends when | ConMit records the agreement | +| Exceptions | N/A | +| Post conditions | N/A | + +``` + +@startuml +skin rose +skinparam ParticipantPadding 50 +skinparam BoxPadding 10 +skinparam lifelineStrategy solid + +box "Near-RT RIC" +participant xApp1 as xApp1 +participant xApp2 as xApp2 + +``` + +``` + +Participant plt as "Near-RT RIC platform" +end box + +participant e2node as "E2 Node" + +plt -> plt: Conflict Detection +plt -> plt: Conflict Resolution Pre-Processing +plt -> xApp1: 1: (E2 related API) E2 Guidance (Modification, parameter name) +plt -> xApp2: 1: (E2 related API) E2 Guidance (Modification, parameter name) +xApp2 -> xApp2: 2a: (Modified) Process the preference +xApp1 -> xApp1: 2a: (Modified) Process the preference +xApp2 -> plt: 2b: (E2 related API) E2 Guidance (Request, preference) +xApp2 -> plt: 2b: (E2 related API) E2 Guidance (Request, preference) +plt -> plt: 3a: (Modified) Compute common value +plt -> xApp1: 3b: (E2 related API) E2 Guidance (Response, common value) +plt -> xApp2: 3b: (E2 related API) E2 Guidance (Response, common value) +plt --> plt: Record agreement +@enduml + +``` + +![Sequence diagram for Implementation Option 1 (Platform Handles E2SM). The diagram shows interactions between xApp1, xApp2, Near-RT RIC platform, and E2 Node. The Near-RT RIC platform performs internal actions: Conflict Detection, Conflict Resolution Pre-Processing, and Record agreement. It sends '1: (E2 related API) E2 Guidance (Modification, parameter name)' to both xApp1 and xApp2. xApp2 performs '2a: (Modified) Process the preference' and sends '2b: (E2 related API) E2 Guidance (Request, preference)' to the platform. The platform then sends '3b: (E2 related API) E2 Guidance (Response, common value)' to both xApp1 and xApp2.](807431d112ae65d5ff9bc8cc7e37956a_img.jpg) + +Sequence diagram for Implementation Option 1 (Platform Handles E2SM). The diagram shows interactions between xApp1, xApp2, Near-RT RIC platform, and E2 Node. The Near-RT RIC platform performs internal actions: Conflict Detection, Conflict Resolution Pre-Processing, and Record agreement. It sends '1: (E2 related API) E2 Guidance (Modification, parameter name)' to both xApp1 and xApp2. xApp2 performs '2a: (Modified) Process the preference' and sends '2b: (E2 related API) E2 Guidance (Request, preference)' to the platform. The platform then sends '3b: (E2 related API) E2 Guidance (Response, common value)' to both xApp1 and xApp2. + +Figure 6.2-1: Implementation Option 1 (Platform Handles E2SM) + +##### 6.2.1.3.2 Implementation 2 (Helper xApp handles E2SM): + +| Use Case Step | Description of the Step | +|------------------|---------------------------------------------------------------------------------------------------------------------------------| +| Goal | ConMit functionality wants to resolve direct parameter conflicts at E2SM level among xApps | +| Actors and Roles | ConMit functionality<br>xApps<br>helper xApp | +| Assumptions | There are at least 2 xApps, 1 ConMit functionality, and 1 helper xApp available. There is at least 1 conflicting RAN parameter. | + +| | | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | The ConMit functionality does not understand/handle E2SM specific information. It uses a helper xApp to process E2SM. | +| Pre-conditions | <p>ConMit functionality is authorized to resolve conflicts among xApps.</p> <p>The helper xApp is authorized to process E2SM information and compute common value (agreement) of the RAN parameter.</p> <p>ConMit may request xApps for information which is necessary to resolve the conflict.</p> | +| Begins when | Conflict detection and resolution pre-processing: A direct RAN parameter has been identified and the xApps have been identified to take part in conflict resolution at the E2SM level. | +| Step 1 (M) | The ConMit functionality requests xApps to send their preference regarding the parameter. | +| Step 2 (M) | <p>a) The xApps compute their preference (either parameter value or the utility function)</p> <p>b) The xApps send these values to ConMit functionality.</p> | +| Step 3 (M) | <p>a) The ConMit functionality forwards the preference to the helper xApp</p> <p>b) The helper xApp computes the common value (i.e., the agreement)</p> <p>c) The helper xApp sends ConMit the common value</p> | +| Step 4 (M) | ConMit forwards the common value to the xApps | +| Ends when | ConMit records the agreement | +| Post conditions | N/A | + +``` + +@startuml +skin rose +skinparam ParticipantPadding 30 +skinparam BoxPadding 10 +skinparam lifelineStrategy solid + +box "Near-RT RIC" +participant xApp1 as xApp1 +participant xApp2 as xApp2 +Participant plt as "Near-RT RIC platform" +Participant xAppH as "Helper xApp" +end box +participant e2node as "E2 Node" + +plt <-> xAppH: (NEW) Conflict Detection (Identify RAN parameter) +plt -> plt: (NEW) Conflict Resolution Pre-processing (Identify xApps) + +plt -> xApp1: 1: (E2 related API) E2 Guidance (Modification, {parameter name}) +plt -> xApp2: 1: (E2 related API) E2 Guidance (Modification, {parameter name}) + +xApp2 -> xApp2: 2a: (Modified) Process the preference +xApp1 -> xApp1: 2a: (Modified) Process the preference +xApp2 -> plt: 2b: (E2 related API) E2 Guidance (Request, {preference}) +xApp2 -> plt: 2b: (E2 related API) E2 Guidance (Request, {preference}) + +plt -> xAppH: 3a: (NEW) (Near-RT RIC API) Forward {preference} +xAppH -> xAppH: 3b: (NEW) Compute common value +xAppH -> plt: 3c: (NEW) (Near-RT RIC API) {common value} + +plt -> xApp1: 4: (E2 related API) E2 Guidance (Response, {common value}) +plt -> xApp2: 4: (E2 related API) E2 Guidance (Response, {common value}) + +plt --> plt: Record agreement +@enduml + +``` + +![Sequence diagram for Implementation Option 2 (Helper xApp Handles E2SM). The diagram shows interactions between xApp1, xApp2, Near-RT RIC (platform), Helper xApp, and E2 Node. Key steps include: 1. E2 related API E2 Guidance (Modification, {parameter name}) from xApp1 and xApp2 to Near-RT RIC platform. 2. (Modified) Process the preference from xApp1 and xApp2 to Near-RT RIC platform. 2b. (E2 related API) E2 Guidance (Request, {preference}) from xApp1 and xApp2 to Near-RT RIC platform. 3a. (NEW) (Near-RT RIC API) Forward {preference} from Near-RT RIC platform to Helper xApp. 3b. (NEW) Compute common value from Helper xApp to Near-RT RIC platform. 3c. (NEW) (Near-RT RIC API) {common value} from Helper xApp to Near-RT RIC platform. 4. (E2 related API) E2 Guidance (Response, {common value}) from Near-RT RIC platform to xApp1 and xApp2. Record agreement from Near-RT RIC platform to Helper xApp.](1bec1afab6abca1a19ce48cc07e855c1_img.jpg) + +``` + +sequenceDiagram + participant xApp1 + participant xApp2 + participant Near-RT RIC as Near-RT RIC platform + participant Helper xApp + participant E2 Node + + Note over xApp1, xApp2, Near-RT RIC: 1: (E2 related API) E2 Guidance (Modification, {parameter name}) + Note over xApp2, Near-RT RIC: 1: (E2 related API) E2 Guidance (Modification, {parameter name}) + Note over xApp1, Near-RT RIC: 2a: (Modified) Process the preference + Note over xApp2, Near-RT RIC: 2a: (Modified) Process the preference + Note over xApp1, Near-RT RIC: 2b: (E2 related API) E2 Guidance (Request, {preference}) + Note over xApp2, Near-RT RIC: 2b: (E2 related API) E2 Guidance (Request, {preference}) + Note over Near-RT RIC, Helper xApp: 3a: (NEW) (Near-RT RIC API) Forward {preference} + Note over Helper xApp, Near-RT RIC: 3b: (NEW) Compute common value + Note over Helper xApp, Near-RT RIC: 3c: (NEW) (Near-RT RIC API) {common value} + Note over Near-RT RIC, xApp1: 4: (E2 related API) E2 Guidance (Response, {common value}) + Note over Near-RT RIC, xApp2: 4: (E2 related API) E2 Guidance (Response, {common value}) + Note over Near-RT RIC, Helper xApp: Record agreement + +``` + +Sequence diagram for Implementation Option 2 (Helper xApp Handles E2SM). The diagram shows interactions between xApp1, xApp2, Near-RT RIC (platform), Helper xApp, and E2 Node. Key steps include: 1. E2 related API E2 Guidance (Modification, {parameter name}) from xApp1 and xApp2 to Near-RT RIC platform. 2. (Modified) Process the preference from xApp1 and xApp2 to Near-RT RIC platform. 2b. (E2 related API) E2 Guidance (Request, {preference}) from xApp1 and xApp2 to Near-RT RIC platform. 3a. (NEW) (Near-RT RIC API) Forward {preference} from Near-RT RIC platform to Helper xApp. 3b. (NEW) Compute common value from Helper xApp to Near-RT RIC platform. 3c. (NEW) (Near-RT RIC API) {common value} from Helper xApp to Near-RT RIC platform. 4. (E2 related API) E2 Guidance (Response, {common value}) from Near-RT RIC platform to xApp1 and xApp2. Record agreement from Near-RT RIC platform to Helper xApp. + +**Figure 6.2-2: Implementation Option 2 (Helper xApp Handles E2SM)** + +#### 6.2.1.4 Evaluation + +The solution requires an enabling detection solution that can identify the RAN parameters and the conflicting xApps. The solution also requires an enabling conflict avoidance solution, i.e., a solution addressing the eventual configuration of the common parameter $p$ in the E2 Node and maintenance/enforcement of the resolution agreement (including failure cases). These mechanisms may be enabled by solutions in clauses 5.2 and 7.2 of the TR. To address open issues 1 and 4 in key issue#1 clause 6.1.1.4, general solutions may be added in conflict avoidance (clause 7.2) key issues. + +The solution addresses the following consideration and open issues in clause 6.1.1: + +- 1- Consideration 1 (in clause 6.1.1.3) is addressed. The resolution may take place both post-action (to avoid further conflict) and pre-action (to avoid future conflict). +- 2- Consideration 7 (in clause 6.1.1.3) is addressed. xApps manage their conflicts by agreeing to a common value. +- 3- Open issue 1 and 4 (in clause 6.1.1.4) are partly addressed by implementation 2, although the technical feasibility of the helper xApp may be studied further. Note that, the utility functions in Method 2 do not expose the business-logic of the xApps but rather only their “interests” on a [0 1] scale. +- 4- Example Method 2 is good to address the combined interests of the xApps because it ensures that all xApps are treated equally after considering their preferences. However, the common value may also be computed by taking into account other factors (in addition to xApp preferences) such as overall network performance. + +## 6.3 Solutions-to-Key Issues Mapping + +**Table 6.3-1: Solutions to Key Issue Mapping** + +| Solution | Key Issue | | | +|----------|-----------|----|----| +| | #1 | #Y | #Z | +| #1 | yes | - | - | +| #Y | - | - | - | +| #Z | - | - | - | + +# 7 Conflict Avoidance + +## 7.1 Key Issues + +### 7.1.1 Key Issue #1 Avoidance of E2-related Conflicts + +#### 7.1.1.1 Description + +This key issue addresses the problem of E2-related conflict avoidance between xApps. Conflict avoidance takes place *pre-action*, i.e., before RIC Control Request or RIC Subscription Request messages have been sent to the E2 Node. Note that, conflict detection and resolution methods/solutions may be seen as part of the overall conflict avoidance goal. + +Currently basic conflict avoidance functionality is enabled by a set of “E2 Guidance” APIs, while conflict detection and resolution may involve methods and processing required to complete this functionality. In more detail, the Near-RT RIC ARCH specification [i.1] already provides the following functionalities: + +- Conflict avoidance may be enabled by the ConMit functionality in the platform as an “E2 Guidance” service. This service consists of the following: + - E2 Guidance Request: An xApp may request guidance from the ConMit functionality to avoid potential E2-related conflicts. + - E2 Guidance Response: The Near-RT RIC platform may provide E2 Guidance towards an xApp as a response to an E2 Guidance Request. The platform performs “conflict mitigation” related processing before providing Guidance. + - E2 Guidance Modification: An E2 Guidance request by an xApp may trigger E2 Guidance from the platform towards other potentially conflicting xApps. + - E2 Guidance Modification: A message from an xApp (e.g., E2 Subscription/Control Request), a message from an external interface, or a message from Near-RT RIC platform’s internal processes may trigger E2 Guidance towards xApps. + +This key issue addresses further (possibly general) requirements and improvements for E2 Guidance mechanism in addition to solutions for conflict detection and resolution in clauses 5.2 and 6.2, respectively. Following are examples of aspects that may be addressed: + +- 1- Improvements in requirements for E2 Guidance. What may the API messages contain, and do we need to extend these APIs? +- 2- How to avoid excessive and unnecessary use of E2 Guidance by xApps? +- 3- How to handle failure cases of conflict resolution? +- 4- How to ensure xApp security and privacy during E2 Guidance procedures? +- 5- The use of E2 Guidance for avoiding previously detected and resolved conflicts. How such agreements should be maintained or enforced for conflict avoidance? +- 6- What kind of external or internal events and messages may lead to triggering of E2 Guidance (or conflict avoidance) in Near-RT RIC? + +#### 7.1.1.2 Impacted Use-Cases + +Void + +#### 7.1.1.3 Considerations + +Solutions for conflict avoidance may consider the following: + +- 1- A solution may enhance the above-mentioned “E2 Guidance” service but may not provide any solutions or methods for conflict detection and/or resolution tasks. Enhancements may support or refer to solutions for detection and resolution in clauses 5.2 and 6.2. +- 2- An xApp may use E2 Guidance (i.e., trigger conflict avoidance) to request if the platform detects a potential conflict. This request may contain E2AP and/or E2SM specific information. +- 3- ConMit functionality may trigger E2 Guidance (e.g., by issuing E2 Guidance Modification) if it detects a potential conflict between xApps. This guidance may be at E2AP and/or E2SM level. +- 4- Resolved Conflicts: Conflict avoidance may consider previously detected and resolved conflicts. + - a. xApps may consider existing conflict resolution “agreements” before requesting guidance from the ConMit functionality in the platform. + - b. Upon receiving a guidance request, ConMit functionality may consider previously detected and/or resolved conflicts between xApps before providing guidance to xApps for conflict avoidance. +- 5- New Conflicts: A guidance request by an xApp may trigger conflict detection and/or resolution by the ConMit functionality as part of the above-mentioned “conflict mitigation” processing. + +#### 7.1.1.4 Open issues + +Following open issues are relevant: + +- 1- ConMit functionality may facilitate conflict avoidance, but it may not be able to provide required guidance at E2SM level without xApp-specific E2SM information. + - b. Furthermore, xApps can, in principle, avoid conflicts but this functionality may need to be part of their design. +- 2- May the platform enforce an existing conflict resolution agreement, e.g., by occasionally denying E2 Subscription or E2 Control requests by xApps? + +- 3- May conflict avoidance involve inter-xApp communication? +- 4- Privacy: How to protect xApps' business logic during conflict avoidance? + +## 7.2 Solutions + +### 7.2.1 Solution #1 xApp based E2SM level service conflict avoidance + +#### 7.2.1.1 Introduction + +Solution #3 for Conflict Detection (clause 5.2.3) provides a mechanism based on Near-RT RIC platform detecting potential direct conflicts between 2 or more xApps using E2AP level information and then using E2 Guidance RICAPI to request identified xApp to perform E2SM level analysis. + +Key Issue #1 for Conflict Resolution (clause 6.1.1) describes the possibility that “xApps may reach a “resolution agreement” themselves directly or indirectly facilitated by conflict mitigation (ConMit) functionality in the platform”. + +Key Issue #1 for Conflict Avoidance (clause 7.1.1) describes the role of avoidance as “*pre-action*, i.e., before RIC Control Request or RIC Subscription Request messages have been sent to the E2 Node” and assumes the possibility that “ConMit functionality may facilitate conflict avoidance, but it may not be able to provide required guidance at E2SM level without xApp-specific E2SM information”, “May conflict avoidance involve inter-xApp communication?” and “How to protect xApps' business logic during conflict avoidance?”. + +This solution assumes that a list of xApps has been identified that are in potential direct conflict with each other and that they may use either inter-xApp message exchange or using the Conflict Mitigation functionality in the platform to route messages between xApps to negotiate a mutually acceptable partition of the E2 Node declared supported E2SM level services. The objective for this negotiation is to agree on which xApps may use which E2SM level service without risk of future direct conflicts. + +At an E2SM level, direct conflicts are essentially due to 2 or more xApps attempting to use exactly the same E2SM specific RIC service. + +For example: + +- A POLICY service using E2SM-RC on a given E2 node. An E2AP level potential direct conflict would exist in this case if different xApps are requesting subscriptions with the same E2AP level information (same E2 Node, same RAN Function, same RIC Action Type) but with different Styles, Actions and/or RAN Parameters. If the xApps could reach an agreement on which E2SM level service are to be used by which xApp then E2SM level conflicts would be avoided. + +#### 7.2.1.2 Functional Description + +Solution #1 for Conflict Detection (clause 5.2.1) describes how the Near-RT RIC platform ([i.1] clause 6.2.3) would use E2AP level information from a requesting xApp and compare this with similar information obtained from other xApps from previous E2 Subscription, E2 Control and/or E2 Guidance requests. The result would be a “E2AP level” potential conflict detection. + +Solution #2 and #3 for Conflict Detection describes how E2SM level information may be used to reduce the list of identified xApps in potential conflict using the Near-RT RIC platform (clause 5.2.2) and xApps (clause 5.2.3) respectively. + +In this solution the Conflict Mitigation functionality in the Near-RT RIC platform may request the set of identified xApps to initiate a Conflict Avoidance negotiation. The proposed avoidance process would focus on negotiation between xApps to determine a mutually exclusive subset of the E2 Node supported RAN Function services. + +Once the negotiation process terminates the xApps would respond to the Conflict Mitigation functionality in the platform to indicate success or failure. The platform may save the outcome of the negotiation and use it for future reference to Conflict Mitigation. + +The platform may also issue a unique “Negotiation Key” to xApps which may then be used in future requests (E2 Guidance, E2 Subscription, E2 Control) to avoid un-necessary repetition of successive conflict detection and conflict avoidance events. + +Finally, the platform may also request an xApp that was party to a previous negotiation to validate whether or not another xApp is acting in compliance with the agreement. + +#### 7.2.1.3 Procedures + +For the E2SM Level conflict avoidance process, RICARCH [i.1] clause 9.3.3.1 (E2 guidance request/response procedure) step 3 “Near-RT RIC platform processes request” and clause 9.3.3.5 (E2 Guidance modification procedure) step 1 “Near-RT RIC platform identifies affected xApps and performs conflict mitigation processing” may be used to perform both conflict detection and conflict avoidance. These procedures would need to be modified so that the Near-RT RIC platform may seek E2SM level analysis and avoidance negotiation from 2 or more xApps. + +The following extensions are proposed to enable E2SM level conflict mitigation processing in xApps: + +- E2 Guidance request/response and E2 Guidance Modification procedures extended: + - Near-RT RIC platform performs E2AP level potential conflict detection using solution proposed in clause 5.2.1 to identify one or more xApps that may be in conflict with requesting xApp + - Identified xApps requested to negotiate to find a suitable solution to avoid conflicts (i.e. to agree on a mutually exclusive subset of E2SM level defined RIC services) + - All xApps respond to Near-RT RIC platform with outcome of negotiation + - xApps may obtain a unique “Negotiation Key” that may be used in subsequent E2 related procedures +- E2 Related procedures extended to support xApps using assigned “Negotiation Key” in request messages to claim successful negotiation has already been performed + +##### RICARCH 9.3.3.1 E2 Guidance request/response procedure + +The purpose of the xApp initiated E2 Guidance request/response API procedure in the Near-RT RIC is to allow authorized xApps to obtain guidance from the Near-RT RIC platform (with the conflict mitigation functionality) prior to initiating an action. + +Guidance from Near-RT RIC platform may include: + +- Indication on whether or not the xApp proposed E2 Related API message or series of messages may result in a conflict with E2 related API messages from other xApps; + +- Recommendations on how the proposed E2 Related message or series of messages should be modified to avoid conflict; +- Modification of previous guidance to other xApps and/or Near-RT RIC platform internal processes. + +This procedure is based on the following assumptions: + +- xApp may use E2 Related API to obtain guidance from Near-RT RIC platform to resolve potential conflicts prior to initiating a RIC function procedure; +- (NEW)Near-RT RIC platform may initiate a conflict mitigation avoidance negotiation process between two or more xApps prior to responding to xApp; +- xApp may use Near-RT RIC platform response in a subsequent procedure (i.e., for a RIC Functional Procedure). + +This procedure is initiated by an xApp using **E2 Related API: E2 Guidance** request. The following outcomes are considered: + +- Near-RT RIC Platform provides guidance to requesting xApp using E2 Related API: E2 Guidance response; +- Near-RT RIC Platform provides modified guidance to another xApp and/or its internal processes. + +| Use Case Stage | Evolution / Specification | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | xApp initiation of Conflict Mitigation guidance. | +| Actors and Roles | <ul style="list-style-type: none"> <li>• xApp: Originator of Conflict Mitigation guidance request;</li> <li>• (NEW)Other xApp(s): One or more other xApps identified by Near-RT RIC platform as being in potential conflict with originator xApp</li> <li>• Near-RT RIC platform, with the following functionalities: <ul style="list-style-type: none"> <li>– Database;</li> <li>– Conflict mitigation.</li> </ul> </li> </ul> | +| Assumptions | <ul style="list-style-type: none"> <li>• Near-RT RIC platform has access to sufficient information to both detect a potential conflict and take a decision on an optimal mitigation solution;</li> <li>• Near-RT RIC platform may initiate guidance towards other xApp as an optional addition response to Guidance Request.</li> </ul> | +| Pre-conditions | <ul style="list-style-type: none"> <li>• xApp has been authorized to request guidance from Near-RT RIC platform for conflict mitigation;</li> <li>• xApp has been assigned xApp ID.</li> </ul> | +| Begins when | xApp determines need to request guidance from Near-RT RIC platform for conflict mitigation. | +| Step 1 (M) | xApp sends <b>E2 Related API E2 Guidance</b> Request to Near-RT RIC platform. | +| Step 2 (M) | Near-RT RIC platform collects related information. | +| Step 3A (M) | (MODIFIED) Near-RT RIC platform performs conflict mitigation detection | +| | [ALT] Remaining step 3 events are executed if Near-RT RIC platform detects a potential conflict | +| Step 3B (O) | (NEW) Near-RT RIC platform requests identified xApps to perform conflict mitigation avoidance | +| Step 3C (O) | (NEW) Identified xApps uses either direct or indirect messaging to negotiate to obtain a mutually acceptable conflict avoidance agreement | +| Step 3D (O) | (NEW) Identified xApps respond to Near-RT RIC platform with outcome of negotiation | +| Step 3E (O) | (NEW) Near-RT RIC platform validates negotiated agreement and stores outcome. | +| Step 4-5 (O) | Near-RT RIC platform may signal conflict and/or provide guidance to internal processes and/or other xApps (see clause 9.3.3.5). (NEW)Message may contain a “negotiation key” that may be used in future requests from xApp | +| Step 6 (M) | Near-RT RIC platform sends <b>E2 Related API E2 Guidance</b> response to xApp. (NEW)Message may contain a “negotiation key” that may be used in future requests from xApp | +| Ends with | xApp continues processing using guidance response. | + +``` + +@startuml +skin rose +skinparam ParticipantPadding 50 +skinparam BoxPadding 10 +skinparam lifelineStrategy solid + +box "Near-RT RIC" +Collections "Other xApp" as xApp +participant "xApp" as xApp2 +Participant plt as "Near-RT RIC platform" +end box + +xApp2 -> plt: 1: (E2 related API) E2 Guidance (Request) +plt -> plt: 2: Collect related information +plt -> plt: 3a: (MODIFIED)Conflict mitigation detection +Alt If platform has identified a potential conflict + plt-->xApp2: 3b. (NEW)Conflict mitigation avoidance request + plt-->xApp: 3b. (NEW)Conflict mitigation avoidance request + xApp<-->xApp2: 3c (NEW)Conflict avoidance negotiation + xApp2-->plt: 3d. (NEW)Conflict mitigation avoidance response + xApp-->plt: 3d. (NEW)Conflict mitigation avoidance response + plt -> plt: 3e. (NEW)Conflict mitigation processing +end +plt --> plt: 4: Guidance to internal processes +xApp <-- plt: 5: (E2 related API) E2 Guidance (Modification) +plt -> xApp2: 6: (E2 related API) E2 Guidance (Response) +@enduml + +``` + +![Sequence diagram illustrating the xApp initiated E2 guidance request/response procedure. The diagram shows three lifelines: Other xApp, xApp, and Near-RT RIC platform. The process starts with xApp sending a request (1) to the platform. The platform performs internal actions (2, 3a) and then sends a request (3b) to xApp. xApp and Other xApp negotiate (3c), and xApp sends a response (3d) to the platform. The platform performs internal processing (3e) and sends guidance (4) to internal processes. Finally, the platform sends a modification (5) to xApp and a response (6) to Other xApp.](9065363d36872d8ba7e99fafb8577f31_img.jpg) + +``` + +sequenceDiagram + participant Other xApp + participant xApp + participant Near-RT RIC platform + + xApp->>Near-RT RIC platform: 1: (E2 related API) E2 Guidance (Request) + Note over Near-RT RIC platform: 2: Collect related information + Note over Near-RT RIC platform: 3a: (MODIFIED)Conflict mitigation detection + alt [If platform has identified a potential conflict] + Near-RT RIC platform-->>xApp: 3b. (NEW)Conflict mitigation avoidance request + xApp-->>Other xApp: 3c (NEW)Conflict avoidance negotiation + Other xApp-->>xApp: 3c (NEW)Conflict avoidance negotiation + xApp-->>Near-RT RIC platform: 3d. (NEW)Conflict mitigation avoidance response + Other xApp-->>Near-RT RIC platform: 3d. (NEW)Conflict mitigation avoidance response + Note over Near-RT RIC platform: 3e. (NEW)Conflict mitigation processing + end + Note over Near-RT RIC platform: 4: Guidance to internal processes + Near-RT RIC platform-->>xApp: 5: (E2 related API) E2 Guidance (Modification) + Near-RT RIC platform-->>Other xApp: 6: (E2 related API) E2 Guidance (Response) + +``` + +Sequence diagram illustrating the xApp initiated E2 guidance request/response procedure. The diagram shows three lifelines: Other xApp, xApp, and Near-RT RIC platform. The process starts with xApp sending a request (1) to the platform. The platform performs internal actions (2, 3a) and then sends a request (3b) to xApp. xApp and Other xApp negotiate (3c), and xApp sends a response (3d) to the platform. The platform performs internal processing (3e) and sends guidance (4) to internal processes. Finally, the platform sends a modification (5) to xApp and a response (6) to Other xApp. + +Figure 7.2-1: RICARCH Figure 9.3.3.1-1: xApp initiated E2 guidance request/response procedure + +##### RICARCH 9.3.3.5 E2 Guidance modification procedure + +The purpose of the E2 Guidance modification procedure is to allow Near-RT RIC platform to signal a modified guidance to the xApp, which can be triggered by the Near-RT RIC platform's internal process (e.g., xApp subscription management), or by a message from the other xApps or external interfaces. + +The guidance may also be used for Near-RT RIC platform internal purposes. + +| Use Case Stage | Evolution / Specification | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | Near-RT RIC platform indicates guidance to an xApp without request from the xApp. | +| Actors and Roles | <ul style="list-style-type: none"> <li>xApp</li> <li>Near-RT RIC platform, with the following functionalities: <ul style="list-style-type: none"> <li>Database</li> <li>Conflict mitigation</li> </ul> </li> <li>External entity (e.g., E2 Node)</li> </ul> | +| Assumptions | <ul style="list-style-type: none"> <li>Near-RT RIC platform is capable of collecting related information, and generating proper guidance for an xApp.</li> </ul> | +| Pre-conditions | <ul style="list-style-type: none"> <li>Message from xApp, message from external interfaces, or Near-RT RIC platform's internal process triggers conflict mitigation in Near-RT RIC platform.</li> </ul> | +| Step 1A (M) | <p>(MODIFIED) Near-RT RIC platform identifies performs conflict mitigation detection. This step may be avoided for the case of a message from xApp that contains an indication that the request is compliant with a previous negotiated agreement. Near-RT RIC platform may request an xApp that was previously party to a negotiated agreement to perform an audit of another xApp's request.</p> | +| | <p>[ALT] Remaining step 1 events are executed if Near-RT RIC platform detects a potential conflict</p> | +| Step 1B (O) | <p>(NEW) Near-RT RIC platform requests identified xApps to perform conflict mitigation avoidance</p> | +| Step 1C (O) | <p>(NEW) Identified xApps uses either direct or indirect messaging to negotiate to obtain a mutually acceptable conflict avoidance agreement</p> | +| Step 1D (O) | <p>(NEW) Identified xApps respond to Near-RT RIC platform with outcome of negotiation</p> | +| Step 1E (O) | <p>(NEW) Near-RT RIC platform validates negotiated agreement and stores outcome.</p> | +| Step 2 (O) | <p>Near-RT RIC platform may provide guidance to the affected xApps using E2 Guidance modification message. (NEW) Message may contain a "negotiation key" that may be used in future requests from xApp</p> | +| Step 3 (O) | <p>Near-RT RIC platform may also use the guidance for internal purposes.</p> | + +``` + +@startuml +skin rose +skinparam ParticipantPadding 50 +skinparam BoxPadding 10 +skinparam lifelineStrategy solid + +Box "Near-RT RIC" +Participant xApp +Collections "Other xApp(s)" as xApp2 +Participant "Near-RT RIC platform" as plt +endbox +Collections "External entity (e.g. Non-RT RIC)" as Otherentity + +Alt message from other xApp(s) triggers conflict mitigation + xApp2 -> plt: Message that may introduce conflict + Alt (NEW)message claims a previous negotiated agreement + plt <--> xApp: (NEW)Conflict mitigation may initiate avoidance audit procedure + end +Else message from external entity triggers conflict mitigation + Otherentity -> plt: Message that may introduce conflict +Else internal processing triggers conflict mitigation + plt -> plt: internal process that may introduce conflict +End + +plt -> plt: 1a. (MODIFIED)Conflict mitigation detection +Alt If platform has identified a potential conflict + plt-->xApp2: 1b. (NEW)Conflict mitigation avoidance request + plt-->xApp: 1b. (NEW)Conflict mitigation avoidance request + +``` + +``` + +xApp<-->xApp2: 1c (NEW)Conflict avoidance negotiation +xApp2-->plt: 1d. (NEW)Conflict mitigation avoidance response +xApp-->plt: 1d. (NEW)Conflict mitigation avoidance response +plt -> plt: 1e. (NEW)Conflict mitigation processing +end +plt --> xApp: 2a: E2 Guidance (Modification) +plt --> xApp2: 2b: E2 Guidance (Modification) +plt --> plt: 3: Guidance for internal purposes +@enduml + +``` + +![Sequence diagram for E2 Guidance Modification Procedure. The diagram shows interactions between xApp, Other xApp(s), Near-RT RIC platform, and External entity (e.g. Non-RT RIC). The process starts with a message from other xApp(s) triggering conflict mitigation. This leads to a (NEW) message claiming a previous negotiated agreement, which may initiate an avoidance audit procedure. Alternatively, a message from an external entity or internal processing triggers conflict mitigation. The Near-RT RIC platform then sends a (MODIFIED) conflict mitigation detection message. If the platform has identified a potential conflict, it sends a (NEW) conflict mitigation avoidance request to the xApp. The xApp then sends a (NEW) conflict avoidance negotiation message to the platform. The platform responds with a (NEW) conflict mitigation avoidance response. The xApp then sends a (NEW) conflict mitigation avoidance response to the platform. The platform sends a (NEW) conflict mitigation processing message to the xApp. Finally, the platform sends E2 Guidance (Modification) messages to the xApp and Other xApp(s), and a guidance message for internal purposes to the platform itself.](e65a45bef5994155c50ca1c83f083d23_img.jpg) + +``` + +sequenceDiagram + participant xApp + participant Other_xApp as Other xApp(s) + participant Near_RT_RIC as Near-RT RIC platform + participant External_entity as External entity (e.g. Non-RT RIC) + + alt [message from other xApp(s) triggers conflict mitigation] + Other_xApp->>Near_RT_RIC: Message that may introduce conflict + alt [(NEW)message claims a previous negotiated agreement] + Near_RT_RIC-->>Near_RT_RIC: (NEW)Conflict mitigation may initiate avoidance audit procedure + else [message from external entity triggers conflict mitigation] + External_entity->>Near_RT_RIC: Message that may introduce conflict + else [internal processing triggers conflict mitigation] + Near_RT_RIC->>Near_RT_RIC: internal process that may introduce conflict + end + end + + Near_RT_RIC-->>Near_RT_RIC: 1a.(MODIFIED)Conflict mitigation detection + + alt [If platform has identified a potential conflict] + Near_RT_RIC->>xApp: 1b. (NEW)Conflict mitigation avoidance request + xApp->>Near_RT_RIC: 1c (NEW)Conflict avoidance negotiation + Near_RT_RIC->>xApp: 1d. (NEW)Conflict mitigation avoidance response + xApp->>Near_RT_RIC: 1d. (NEW)Conflict mitigation avoidance response + Near_RT_RIC->>xApp: 1e. (NEW)Conflict mitigation processing + end + + Near_RT_RIC->>xApp: 2a: E2 Guidance (Modification) + Near_RT_RIC->>Other_xApp: 2b: E2 Guidance (Modification) + Near_RT_RIC->>Near_RT_RIC: 3: Guidance for internal purposes + +``` + +Sequence diagram for E2 Guidance Modification Procedure. The diagram shows interactions between xApp, Other xApp(s), Near-RT RIC platform, and External entity (e.g. Non-RT RIC). The process starts with a message from other xApp(s) triggering conflict mitigation. This leads to a (NEW) message claiming a previous negotiated agreement, which may initiate an avoidance audit procedure. Alternatively, a message from an external entity or internal processing triggers conflict mitigation. The Near-RT RIC platform then sends a (MODIFIED) conflict mitigation detection message. If the platform has identified a potential conflict, it sends a (NEW) conflict mitigation avoidance request to the xApp. The xApp then sends a (NEW) conflict avoidance negotiation message to the platform. The platform responds with a (NEW) conflict mitigation avoidance response. The xApp then sends a (NEW) conflict mitigation avoidance response to the platform. The platform sends a (NEW) conflict mitigation processing message to the xApp. Finally, the platform sends E2 Guidance (Modification) messages to the xApp and Other xApp(s), and a guidance message for internal purposes to the platform itself. + +Figure 7.2-2: RICARCH Figure 9.3.3.5-1 E2 Guidance Modification Procedure + +#### 7.2.1.4 Evaluation + +This solution offers a sound solution for both E2AP and E2SM level direct conflict avoidance, allows xApp to negotiate without revealing business logic, supports a solution to avoid repetition of the conflict avoidance process and supports a solution to audit claims from xApps to be compliant with previous negotiated agreements. + +The solution avoids the need to align Near-RT RIC platform support of each E2SM with the versions used by each xApp. It does however rely on xApps supporting the appropriate E2SM versions. + +## 7.3 Solutions-to-Key Issues Mapping + +**Table 7.3-1 Solutions to Key Issue Mapping** + +| Solution | Key Issue | | | +|----------|-----------|----|----| +| | #1 | #Y | #Z | +| #1 | yes | - | - | +| #Y | - | - | - | +| #Z | - | - | - | + +# 8 Conclusions + +## 8.1 Conflict Detection + +### 8.1.1 Key issues and potential solutions + +All key issues are addressed by the proposed solutions as shown in clause 5.3. However, the current Near-RT RIC ARCH specification [i.1] and Near-RT RIC APIs only partially support the solutions. + +### 8.1.2 Solution requirements + +The following preliminary requirements can be derived: + +- 1- Solution #1 and #2 described in clauses 5.2.1 and 5.2.2, respectively, are both supported by existing signalling. However, Solution #2 further assumes that the Near-RT RIC platform may inspect E2SM information contained in E2 Subscription Request, E2 Control Request, and E2 Guidance Request/Response messages initiated by xApps. +- 2- Solution #3 requires that, when the ConMit functionality inspects the E2AP information contained in the above-mentioned messages by an xApp, it may suspect a potential conflict with another xApp. The ConMit functionality may then request xApps to perform the E2SM level analysis, thereby avoiding the need for the platform to do the same. +- 3- Solution #4 requires that the platform may seek further information from the xApps after identifying a potential conflict. Alternatively, Solution #4 may be triggered by the xApp which detects a potential conflict with another xApp. +- 4- Solution #4 requires that either the platform or a special helper xApp may collect data from the RAN for conflict discovery/detection. +- 5- Solution #4 requires that the platform or a special helper xApp has ability/functionality to perform AI/ML based data analysis to detect potential indirect/implicit conflicts between xApps. +- 6- Solutions #5, #6, and #7 assume that a certain "dependency information" containing information about couplings between RAN parameters, resources, and KPIs is generated. Given this information, the ConMit functionality can then enhance its conflict mitigation processing. The dependency information can be provided to the ConMit using, e.g., the O1 interface. +- 7- Solution #6 assumes that along with the dependency information, ConMit or a helper xApp may further use AI/ML methods to predict impacts of the conflicting RAN parameters on the KPIs and stability of the network. + +## 8.2 Conflict Resolution + +### 8.2.1 Key Issues and potential solutions + +All key issues are addressed by the proposed solutions as shown in clause 6.3. However, the current near-RT RIC ARCH specification [i.1] and Near-RT RIC APIs only partially support the proposed solutions. + +### 8.2.2 Solution requirements + +The following preliminary requirements can be derived: + +- 1- Solution #1 assumes that, before resolution of direct parameter conflicts is triggered, conflicts at E2SM level (parameter level) have already been discovered and attempts at conflict avoidance by e.g., using Solution #1 in clause 7.2.1, have not been successful. +- 2- Solution #1 described in clauses 6.2.1 requires that ConMit requests the xApps for their preference about the RAN parameter(s) in conflict and computes a "common value" on behalf of the xApps. This solution also assumes an intelligent/computing mechanism inside the ConMit or a helper xApp to compute such a common value by taking into xApp preferences. + +## 8.3 Conflict Avoidance + +### 8.3.1 Key Issues and potential solutions + +All key issues are addressed by the proposed solutions as shown in clause 7.3. However, the current near-RT RIC ARCH specification [i.1] and Near-RT RIC APIs only partially support the solutions. + +### 8.3.2 Solution requirements + +The following preliminary requirements can be derived: + +- 1- Solution #1 assumes that a list of xApps in conflict with each other has been generated. Solutions in clause 5 may be used for this purpose depending on the type of conflict. +- 2- Solution #1 works on the basis of further conflict avoidance by orthogonalizing E2SM level services usage within the given E2 Node by the xApps, assuming that such a partition or separation is possible and agreeable to the involved xApps. +- 3- Solution #1 requires either inter-xApp message exchange or using the ConMit functionality in the platform to route messages between xApps to negotiate a mutually acceptable partition of the E2 Node declared supported E2SM level services. + +NOTE: Solution #1 may serve as a pre-requisite for conflict resolution solutions in clause 6. In more detail, the failure of an avoidance agreement between xApps means that conflicts between xApps cannot be avoided, and an intervention by the ConMit functionality is required. Solution #1 in clause 6.2.1, e.g., resolves the direct conflict in that the platform computes a common value for the conflicting RAN parameter itself. + + + +# --- Annex A: Title of annex + +# --- Annex Bibliography + +# Annex:Change history/Change request (history) + +| Date | Revision | Description | +|------------|------------|-----------------------------------------------------------------------| +| 2023.11.20 | 00.00.00 | Dokument Skeleton | +| 2023.11.27 | 00.00.01v1 | Dokument Skeleton Cleanup | +| 2023.11.30 | 00.00.01v2 | Addition of subsections 4.x and 5.1.x.2, 6.1.x.2, and 7.1.x.2 | +| 2023.12.12 | 00.00.01 | Approved Baseline | +| 2024.01.15 | 00.00.02 | Inclusion of NOK CR 0001 after agreement in WG3# 210 | +| 2024.02.12 | 00.00.03 | Inclusion of NOK CRs 0002 and 0003 after agreement in WG3#2014 | +| 2024.03.19 | 00.00.04 | Inclusion of NOK CRs 0004, 0005, 0006, 0007, and 0008 after agreement | +| 2024.05.27 | 00.00.05 | Inclusion of NOK CRs 0009 and 0010 | +| 2024.07.02 | 00.00.06 | Inclusion of SYM CRs 0007, 0008, and 0009 | +| 2024.07.11 | 00.00.07 | Inclusion of NOK CR 0011 | +| 2024.07.23 | 01.00.00 | Version 1 after editorial fixes and approval vote | \ No newline at end of file diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/083cf31f954126de4a2d9d49aba4205f_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/083cf31f954126de4a2d9d49aba4205f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12278b0094abfe755eaeb36549453f14bcdbb949 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/083cf31f954126de4a2d9d49aba4205f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:25b5a54113b45f22bf15047802355e56c224c8e5df9a1c3a7cbfce18634efd8e +size 22829 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/0c6499c0eff2c7167c61e7089eb6468d_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/0c6499c0eff2c7167c61e7089eb6468d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6b83fd258532c39fecc9b6599bbfaa7a4d356807 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/0c6499c0eff2c7167c61e7089eb6468d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:29ef732432ffd74ef8494082bcb2d7fcf7c19fb54f0b58475061ae6b4766c565 +size 27846 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/0ed168419210254d52e787f90251562e_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/0ed168419210254d52e787f90251562e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..132f37e45fecc51e3a0baee32a06376e25aaffec --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/0ed168419210254d52e787f90251562e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b9c019f10f665c5a12ef317307c8c17cf9a8bd1bdd792e4070744a268245dff1 +size 4577 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/118251355d912bbd2f8fe0cb566ba91b_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/118251355d912bbd2f8fe0cb566ba91b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..41376671057aa7fa9f34e7ec2d3125aab9fc4848 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/118251355d912bbd2f8fe0cb566ba91b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd0896eeaab08b6bf4a8ed8f7623a19ff0359fe94c02e6e018537ee45dbcb08b +size 4554 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/1ec46460065c10d2c8a46803189839aa_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/1ec46460065c10d2c8a46803189839aa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f182ea5af265427323f807ec7aa1135726d8c40e --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/1ec46460065c10d2c8a46803189839aa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ff657efbda2a1d655d9ea9710fcd420f5b56f9f75cc5ac471b33368554850b11 +size 22676 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/205052185cb5539c5fd3a9ea1f2aab08_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/205052185cb5539c5fd3a9ea1f2aab08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f5a2c1d0c1c34d0d11b3ab2b443bac698339febf --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/205052185cb5539c5fd3a9ea1f2aab08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:913c0f86919b70ae2c3521f5368a40c65421d23320dfb4297e6b2a5712ab067e +size 21003 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/20a2acad7d24c617437672ec064d43f5_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/20a2acad7d24c617437672ec064d43f5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3001b93cedc4d9c9feb3f1572c4af9f86a41a4c8 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/20a2acad7d24c617437672ec064d43f5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:57fb8179c097cb090ecd6dc7d75db237953b407b42855779403f261a1a986ac4 +size 27179 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/2477e6c2d24a37cf2dfa950078d99cc6_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/2477e6c2d24a37cf2dfa950078d99cc6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..be6527d6d2505975438efe97ee407eb72da5c824 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/2477e6c2d24a37cf2dfa950078d99cc6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:17fd39efc608f0e40b8ff82dc3dffd53b75ecdc27996b79b735f7b1dd4cf2151 +size 18431 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/25adb1779caeee8152d405858cc3057d_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/25adb1779caeee8152d405858cc3057d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6eef5c93231c056f0f6940b04d0157c148dabd43 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/25adb1779caeee8152d405858cc3057d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dceb5f802d9708c2e3ad5ef883aa30a14bb101d97d4717f9668a9f52599be675 +size 19123 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/37052f7c575029805b65a7f71fb4ac56_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/37052f7c575029805b65a7f71fb4ac56_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a1ad198ae77bdc72665811a5706a4a3a2e37541c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/37052f7c575029805b65a7f71fb4ac56_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:98489878a7218cc47b351663cd8e953cb5e6146c112a1530a69fa4ad458f558a +size 16030 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/3750156e1187696fb7e00a60e2a18323_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/3750156e1187696fb7e00a60e2a18323_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d9042726bdbd38bf1f05b383a2a331adbcefa9fa --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/3750156e1187696fb7e00a60e2a18323_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5363003d259e6d6ed53160693786931f2342271aa00027c10021a740c00f9937 +size 29138 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/380d95ac3779a767fbfa5330b29f28f9_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/380d95ac3779a767fbfa5330b29f28f9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b64ecd27d4b6e58e3e215b3439dac809baf5aff8 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/380d95ac3779a767fbfa5330b29f28f9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e1f094b69af13feb5f3218d57212ce3e1cc8d72b71131c271f5c7dd75d52eb1b +size 22322 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/38ba70877eb8ae3317247595766156c1_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/38ba70877eb8ae3317247595766156c1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8fe57d585c1e9b9dc0f84c44c472af1c1045908a --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/38ba70877eb8ae3317247595766156c1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e75d8ad1b35c2ad9f4261ff72cf222c7f8a4a52ad06db72a077fe079c5d4499 +size 21374 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/38db3420ebc08106dccb6f0ecc6a0d6e_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/38db3420ebc08106dccb6f0ecc6a0d6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de50d0a0cf2bec473e4ab494e0aaeb92d4219783 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/38db3420ebc08106dccb6f0ecc6a0d6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:670aedb94e8c2b1cac15a88c21c471ecd5d7ca775c0d54a923319ffde7def695 +size 4490 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/405c9cf2532981047451ccb349609c9d_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/405c9cf2532981047451ccb349609c9d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f2bf8746e9d8b044b82c2d5f7c230100e4444bae --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/405c9cf2532981047451ccb349609c9d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:292a3a75a72d0b62b695d079985b2f3f688a8336b44aaa7fe2ce5ec131826407 +size 27575 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/423a557532703319d8c5524560cb5fbe_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/423a557532703319d8c5524560cb5fbe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d800a838328bf1e073df53794d2949ad002d772 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/423a557532703319d8c5524560cb5fbe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:07c79bdc373789afd7f1b2dac1b536d31620e07631637881e00f5f48f5e5f611 +size 23808 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/45e40350c62c2092ded75076be8626cc_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/45e40350c62c2092ded75076be8626cc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9ac2067cdf40e197734a6294cc8e0e934d347b4b --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/45e40350c62c2092ded75076be8626cc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:78ef2fe2f6794065f4d0182c14d7841b4b947873121bd3798fd85b4619c07abe +size 18996 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/4d74c95402ccff1aee1004335fb98f94_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/4d74c95402ccff1aee1004335fb98f94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1be327ad610d818fc732f491ee8c6b4a67178ea4 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/4d74c95402ccff1aee1004335fb98f94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0baaa87dbddcdfd74bfd45a9dee844c88661d6df7237ccc8c256f9fc032460f5 +size 27106 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/58d512af60456c43a2714b54d865ecec_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/58d512af60456c43a2714b54d865ecec_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..420a154c1c1c335fd48d1a6f77f01dc6afb3b455 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/58d512af60456c43a2714b54d865ecec_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:406b95b5214e85636d9e5b933584db884fec10d16eccc416431b9225f653fd14 +size 16150 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/591890046c73f1ed213267987b143ebb_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/591890046c73f1ed213267987b143ebb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d5dc0d347f191f665d33f5c81ec0b289f361724d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/591890046c73f1ed213267987b143ebb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c05d48830aa7051fbe40cbb33243c9978ffdc2079f8bf40d9ab6117a56af7c8d +size 4542 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/5e8fd51f64c880cffc302a40c51b930b_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/5e8fd51f64c880cffc302a40c51b930b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2db51e792c83ce5da27a71bf7f8d9c2dbfe64c07 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/5e8fd51f64c880cffc302a40c51b930b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cb2fe572407c856f6a6989c08a55d966b3bdb4e35c60777b6d9850043d06ecfc +size 25168 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/63061e2677d6286caee26e8886bc5d08_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/63061e2677d6286caee26e8886bc5d08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25eee56dafa33c0f0ed8fe8cb1efadca29ade851 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/63061e2677d6286caee26e8886bc5d08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:94aa0b428d4467609d7902840f07366f5fe6b47dfdf666acd777cfd513f70e91 +size 27412 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/6804f60a59e994b5203b1723a155291e_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/6804f60a59e994b5203b1723a155291e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..68b70caa7c94c41fe3629a3dcd32edc95ca0f868 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/6804f60a59e994b5203b1723a155291e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e5f9686243b3082ee568df8eccd6060d704423991078fde8343a7d9080ebedbc +size 19336 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/68d6201add786997d64525e3d9686a83_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/68d6201add786997d64525e3d9686a83_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cb437600e15e6bc5ee926f531fcf8c940b18d91d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/68d6201add786997d64525e3d9686a83_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:032ce871a2b6100612508d1130133157c7d66dba2471ed1115faecb4a0d0b3db +size 25594 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/697f8ef39284553d8d9a418ec08eea28_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/697f8ef39284553d8d9a418ec08eea28_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f0a46038ccb8becc6d302536a600b6f7e815cafa --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/697f8ef39284553d8d9a418ec08eea28_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e2d3f909d9db9d663e88b49ec1d9a6e0dfd15a2d7fa9ec95d9ca45029677774f +size 15351 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/7555580bd5ef3875cc31358e3e751ce3_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/7555580bd5ef3875cc31358e3e751ce3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0ff84242ccb467182d91aac8bf11c1ee8be11e01 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/7555580bd5ef3875cc31358e3e751ce3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad8ab622f33ead6c7f3a1e4ccd6e3d03ee3f1352625c28cc9705d969f1e4e04 +size 22449 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/7c49c7d46efa13a77606d14ea3118518_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/7c49c7d46efa13a77606d14ea3118518_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..886e957861a8a33c67ec3fbfd7eb80284f5802cf --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/7c49c7d46efa13a77606d14ea3118518_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b4ed694df412db0c741c46e25fe1fed1f48b16082b297dda59eee2ba3a64f9c5 +size 20823 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/7eb2577b5e262b911d748cd6229145ad_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/7eb2577b5e262b911d748cd6229145ad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..087983088ae9948e7fb7383ef99dd6490e211abf --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/7eb2577b5e262b911d748cd6229145ad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7df9f38d007e33dd4a3e708ebadd362ec1492e6fd445749a750374c9b942d4c2 +size 23015 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/88090d83e337f2a83f461378216f0810_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/88090d83e337f2a83f461378216f0810_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4b9cfc0d1fd907fc43486af7b2bc9cb00702840c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/88090d83e337f2a83f461378216f0810_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4bdab73a68f0fcf67b72c8cf40e90a4611de41b97d8db9048dcc8fe0a828cc50 +size 4482 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/88d0648b30c3d4c271897f352c4de4a5_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/88d0648b30c3d4c271897f352c4de4a5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0bb86b24594fcc59021f4530f31410dccd65ff33 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/88d0648b30c3d4c271897f352c4de4a5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2af85e75727134589950aa91678bd923ba581b044a64379a28725a7484347746 +size 4550 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/91db642834e2e448c6355358edc62e23_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/91db642834e2e448c6355358edc62e23_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..38341884f73def08191ec4ce6048cfc24ac03625 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/91db642834e2e448c6355358edc62e23_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:641b3398850b7639eccef9bbf6f2db34b67ea82ac37642cc7ea626423ddc81a9 +size 28292 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/95086bec2ff733af5890459fb8fda60f_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/95086bec2ff733af5890459fb8fda60f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ffe7d453cbf0e4d912504e5fce2d57a900e1052b --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/95086bec2ff733af5890459fb8fda60f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b8032d1177f87f38853cb3e5262a4be4d1bb75ed4511cddf056845d3cef60eb +size 20218 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/992cfd0e5280a40cdcfb9020f33b69bc_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/992cfd0e5280a40cdcfb9020f33b69bc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6329dc95d3546475eaef3977ec09146a25f41b2d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/992cfd0e5280a40cdcfb9020f33b69bc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1db0c1624d4f99ad7ee5fc5f01beccf4159a14c2316157a8f5b40066463a483f +size 23785 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/9947609714e01df45158b956f9007442_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/9947609714e01df45158b956f9007442_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de6a6b65fdc06886e387439c477ddf9856b0e9bf --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/9947609714e01df45158b956f9007442_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3e2ffd119351618baa718d60ef913167f3ce7044a71f2007b59cc862c6ebc05a +size 32049 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/9c2e42280fbe5b6298efb323592e09f8_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/9c2e42280fbe5b6298efb323592e09f8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..358e284f21dc31575c497867c9b5d1acdd22dae2 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/9c2e42280fbe5b6298efb323592e09f8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d0490f386e495272c238f4678f717eb26d0b1c4bf4431f0f95c615e1996e68c6 +size 26920 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/9fb113f9b7e9fde28065d4eccec01ee0_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/9fb113f9b7e9fde28065d4eccec01ee0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2ed15487462b3d3eb06edf672f7d945550636c8 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/9fb113f9b7e9fde28065d4eccec01ee0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:893075875b3c6bf6828ffa4385941adeca2261bc2928a944a7879ee56d3c7d18 +size 26807 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a46604d3bdae30b813025088d10b722c_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a46604d3bdae30b813025088d10b722c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9ef63a2944ad26cc3da95413e3c10837991680a7 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a46604d3bdae30b813025088d10b722c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f2daf4ea54a44cb5ea56ac755ad846fa94e84285b7d938d654cc632504602e7d +size 23142 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a62d44a3d5bd1b617b68abec7cccbb13_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a62d44a3d5bd1b617b68abec7cccbb13_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..94bfba4273f645c8e12e668870f4d8870508ef7c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a62d44a3d5bd1b617b68abec7cccbb13_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c44c6baf32d570597be48939a5a7ec1da34ef5c9771bf7d9cef28b9c8498858a +size 25124 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a719f7cc5afb2229df7576211c25123f_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a719f7cc5afb2229df7576211c25123f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3f5a3722bd47fe783f845042823d0471987b8eb8 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a719f7cc5afb2229df7576211c25123f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:af8404ba7db84e45e2abab861eebd91f4e601aaaedd005d2ba5bfd638d0b41d4 +size 4552 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a854945d8dbedca382e6c2c6921e3b22_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a854945d8dbedca382e6c2c6921e3b22_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a63c8476f8c1cceded864979983891871a7cee45 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a854945d8dbedca382e6c2c6921e3b22_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2019838e1c098cc74e7fca8302b20bdece3b7d1532fa443cd23f835733176a3f +size 21517 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a8cff121ed47c877b9b6e30c21d09225_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a8cff121ed47c877b9b6e30c21d09225_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..570c890aa41af8965ec8f8207a2080b522de6071 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a8cff121ed47c877b9b6e30c21d09225_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a9c4dd14ef3f10ac321438150206b562110711c5861b50073ef4871af1e89211 +size 26955 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a9adce18b696d8c554877de0bf88ef02_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a9adce18b696d8c554877de0bf88ef02_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7073b1bdf7ea42435f9b99642b859384c0dbe106 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/a9adce18b696d8c554877de0bf88ef02_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:195d22f26de9c04673899ce8d1543a5321ca9bc2c8f7d8ae1699a498069c3c4f +size 4528 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/b48083788f638a33d728bde1acd0560a_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/b48083788f638a33d728bde1acd0560a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4b152da3dc71a2ca02d4faf20c0c2a5f6d8c95e9 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/b48083788f638a33d728bde1acd0560a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5260a0ac725ffcfb75c83f83bd5b2f46b01dd13e647c21c16286dd9f4fd22b12 +size 19607 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/ba293eb5effd848182a005ca9e198324_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/ba293eb5effd848182a005ca9e198324_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3a2c9c8a9e411a6e6a87916763d3afd10df53f6f --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/ba293eb5effd848182a005ca9e198324_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf0aa1794cf635f453440dd725c729f6fd2f09f606010bc6c021a9268d330412 +size 19925 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/bb616915edf9be8a8255f5ef2f442f4b_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/bb616915edf9be8a8255f5ef2f442f4b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b3f88fc880b5ce3d49ba298e785a32d5497d91eb --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/bb616915edf9be8a8255f5ef2f442f4b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e465793c18f512d300b5f86bcec903833f58c6120f0410371d143a704f4d7262 +size 16716 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/bba9f1de9f292798f6d2592d8466eaee_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/bba9f1de9f292798f6d2592d8466eaee_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..40c3fb4a7f5132fa87601eb2c6531b34ebfbbbb4 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/bba9f1de9f292798f6d2592d8466eaee_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a5b93a2c8007ba3cc8775cef342370b68772a150dfd3edb4b8a5d6f2daff3bbe +size 22072 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/c6359a2dd418dc2cbdce8601a2057f01_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/c6359a2dd418dc2cbdce8601a2057f01_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9942f9f0d42dc27a52f9bc39bffb3827f0e6fac3 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/c6359a2dd418dc2cbdce8601a2057f01_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b9250af1c2ce61afa33da97f07f343d1e55c5721bbed902b481241e119997b03 +size 26504 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/c7871e85597e7285b99279006895a34b_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/c7871e85597e7285b99279006895a34b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ecb47dfe7ee687e6115549da92203a000e93b673 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/c7871e85597e7285b99279006895a34b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ba31b3f2af4a665cb548fdb6d84a3dddb5e30826788aff4d31fa34760c182a5c +size 4540 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/d18081f600ec5887204f5bd91b6e156b_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/d18081f600ec5887204f5bd91b6e156b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd0fbfb90bfcab4c7b9abcc7558b1dc2edcb04ee --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/d18081f600ec5887204f5bd91b6e156b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:747295ae55207dd41a90d61795f7e9e6a116f088dff36eb6d3861b5ac04f8adf +size 23615 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/d30244318e36e17a0dcde325fbeaa4cb_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/d30244318e36e17a0dcde325fbeaa4cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b5644e661d31fe030aed27e6e7f735a887a37a2e --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/d30244318e36e17a0dcde325fbeaa4cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e716d2371a3e1a7dd4dd55b8956e3d8b3787aec06ae7314d60cd964f35a17ad6 +size 21470 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/dde8b736178d4fcdd60f812a89690fac_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/dde8b736178d4fcdd60f812a89690fac_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..adcfed1dbfa630d21bc15823e63b00e82c25c086 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/dde8b736178d4fcdd60f812a89690fac_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1d775d6aab0982bb5a2ecac75653c5dd215052fa71763de85652676f38876411 +size 31120 diff --git a/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/raw.md b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..0c82de1dd808490fc5f06acc2dbff92cccce3a58 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00/raw.md @@ -0,0 +1,7735 @@ + + +# --- **O-RAN Work Group 3 (WG-3) Near-Real-time RAN Intelligent Controller and E2 Interface E2 Application Protocol (E2AP)** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +"© 2019. 3GPP™ TSs and TRs are the property of ARIB, ATIS, CCSA, ETSI, TSDSI, TTA and TTC who jointly own the copyright in them. They are subject to further modifications and are therefore provided to you "as is" for information purposes only. Further use is strictly prohibited." + +"© 2020. 3GPP™ TSs and TRs are the property of ARIB, ATIS, CCSA, ETSI, TSDSI, TTA and TTC who jointly own the copyright in them. They are subject to further modifications and are therefore provided to you "as is" for information purposes only. Further use is strictly prohibited." + +# --- Contents + +| | | +|--------------------------------------------------------------|----| +| List of figures..... | 6 | +| List of tables ..... | 6 | +| Foreword..... | 8 | +| Modal verbs terminology..... | 8 | +| 1 Scope ..... | 9 | +| 2 References ..... | 9 | +| 2.1 Normative references ..... | 9 | +| 2.2 Informative references..... | 10 | +| 3 Definition of terms, symbols and abbreviations..... | 10 | +| 3.1 Terms..... | 10 | +| 3.2 Symbols..... | 11 | +| 3.3 Abbreviations ..... | 11 | +| 4 General ..... | 12 | +| 4.1 Procedure specification principles..... | 12 | +| 4.2 Forwards and backwards compatibility ..... | 12 | +| 4.3 Specification notations ..... | 12 | +| 5 E2AP Services..... | 13 | +| 5.1 E2AP procedure modules..... | 13 | +| 5.2 Parallel transactions..... | 13 | +| 6 Services expected from signalling transport..... | 13 | +| 7 Functions of E2AP ..... | 13 | +| 8 E2AP procedures..... | 13 | +| 8.1 Elementary procedures ..... | 13 | +| 8.2 RIC Functional procedures..... | 15 | +| 8.2.1 RIC Subscription procedure..... | 15 | +| 8.2.2 RIC Subscription Delete procedure ..... | 18 | +| 8.2.2A RIC Subscription Delete Required procedure..... | 19 | +| 8.2.2B RIC Subscription Audit procedure..... | 20 | +| 8.2.3 RIC Indication procedure..... | 22 | +| 8.2.4 RIC Control procedure..... | 23 | +| 8.2.5 RIC Subscription Modification procedure ..... | 24 | +| 8.2.6 RIC Subscription Modification Required procedure ..... | 28 | +| 8.2.7 RIC Query procedure..... | 29 | +| 8.2.8 RIC Service Load Status procedure ..... | 31 | +| 8.2.9 RIC Service Load Update procedure ..... | 32 | +| 8.2.10 RIC Subscription State Control procedure..... | 33 | +| 8.2.11 RIC Assistance procedure..... | 35 | +| 8.2.12 RIC Assistance Indication procedure..... | 36 | +| 8.2.13 RIC Assistance Halt procedure..... | 37 | +| 8.3 Global procedures..... | 38 | +| 8.3.1 E2 Setup procedure..... | 38 | +| 8.3.2 Reset procedure ..... | 40 | +| 8.3.3 Error Indication..... | 41 | + +| | | | +|--------|---------------------------------------------------|-----| +| 8.3.4 | RIC Service Update procedure ..... | 42 | +| 8.3.4A | RIC Service Query procedure..... | 44 | +| 8.3.5 | E2 Node Configuration Update procedure..... | 45 | +| 8.3.6 | E2 Connection Update procedure ..... | 47 | +| 8.3.7 | E2 Removal procedure..... | 48 | +| 9 | Elements for E2AP communication ..... | 50 | +| 9.0 | General ..... | 50 | +| 9.1 | Message functional definition and content ..... | 51 | +| 9.1.1 | Messages for RIC Functional procedures ..... | 51 | +| 9.1.2 | Messages for Global Procedures..... | 70 | +| 9.2 | Information Element definitions..... | 83 | +| 9.2.0 | General..... | 83 | +| 9.2.1 | Cause ..... | 83 | +| 9.2.2 | Criticality Diagnostics ..... | 86 | +| 9.2.3 | Message Type ..... | 87 | +| 9.2.4 | Global RIC ID..... | 87 | +| 9.2.5 | Time to wait ..... | 88 | +| 9.2.6 | Global E2 Node ID ..... | 88 | +| 9.2.7 | RIC Request ID..... | 88 | +| 9.2.8 | RAN Function ID ..... | 89 | +| 9.2.9 | RIC Event Trigger Definition ..... | 89 | +| 9.2.10 | RIC Action ID..... | 89 | +| 9.2.11 | RIC Action Type..... | 89 | +| 9.2.12 | RIC Action Definition ..... | 89 | +| 9.2.13 | RIC Subsequent Action ..... | 90 | +| 9.2.14 | RIC Indication Sequence Number (SN)..... | 90 | +| 9.2.15 | RIC Indication Type ..... | 90 | +| 9.2.16 | RIC Indication message ..... | 90 | +| 9.2.17 | RIC Indication header..... | 90 | +| 9.2.18 | RIC Call Process ID..... | 91 | +| 9.2.19 | RIC Control message ..... | 91 | +| 9.2.20 | RIC Control header..... | 91 | +| 9.2.21 | RIC Control Ack Request ..... | 91 | +| 9.2.22 | Void ..... | 91 | +| 9.2.23 | RAN Function Definition ..... | 92 | +| 9.2.24 | RAN Function Revision..... | 92 | +| 9.2.25 | RIC Control Outcome..... | 92 | +| 9.2.26 | E2 Node Component Interface Type ..... | 92 | +| 9.2.27 | E2 Node Component Configuration ..... | 92 | +| 9.2.28 | E2 Node Component Configuration Acknowledge ..... | 97 | +| 9.2.29 | Transport Layer Information..... | 97 | +| 9.2.30 | TNL Association Usage..... | 98 | +| 9.2.31 | RAN Function OID..... | 98 | +| 9.2.32 | E2 Node Component ID ..... | 98 | +| 9.2.33 | Transaction ID ..... | 99 | +| 9.2.34 | RIC Subscription Time ..... | 99 | +| 9.2.35 | RIC Action Execution Order ..... | 99 | +| 9.2.36 | RIC Query Header ..... | 99 | +| 9.2.37 | RIC Query Definition ..... | 99 | +| 9.2.38 | RIC Query Outcome ..... | 100 | +| 9.2.39 | RIC Subscription Audit Flag ..... | 100 | +| 9.2.40 | Load Measurement ID ..... | 100 | +| 9.2.41 | RIC Load Information ..... | 100 | +| 9.2.42 | RIC Service Load Information..... | 100 | +| 9.2.43 | RIC Load Request..... | 101 | + +| | | | +|--------|-------------------------------------------------------------------|-----| +| 9.2.44 | RIC Service Load Request..... | 101 | +| 9.2.45 | RIC Load Confirm..... | 101 | +| 9.2.46 | RIC Service Load Confirm..... | 102 | +| 9.2.47 | RIC Assistance Header..... | 102 | +| 9.2.48 | RIC Assistance Message..... | 102 | +| 9.2.49 | RIC Assistance Update..... | 102 | +| 9.2.50 | RIC Assistance Update Number..... | 102 | +| 9.2.51 | RIC Assistance Outcome..... | 103 | +| 9.2.52 | RIC Assistance SN..... | 103 | +| 9.2.53 | Service Level Cause..... | 103 | +| 9.3 | Message and Information Element Abstract Syntax (with ASN.1)..... | 103 | +| 9.3.1 | General..... | 103 | +| 9.3.2 | Usage of private message mechanism for non-standard use..... | 104 | +| 9.3.3 | Elementary Procedure definitions..... | 104 | +| 9.3.4 | PDU definitions..... | 109 | +| 9.3.5 | Information Element definitions..... | 142 | +| 9.3.6 | Common definitions..... | 150 | +| 9.3.7 | Constant definitions..... | 151 | +| 9.3.8 | Container definitions..... | 154 | +| 9.4 | Message transfer syntax..... | 156 | +| 9.5 | Timers..... | 156 | +| 10 | Handling of unknown, unforeseen and erroneous protocol data..... | 157 | +| | Annex (informative): Change History..... | 158 | + +# List of figures + +| | | +|--------------------------------------------------------------------------------------------------|----| +| Figure 8.2.1.2-1: RIC Subscription procedure, successful operation ..... | 15 | +| Figure 8.2.1.3-1: RIC Subscription procedure, unsuccessful operation ..... | 17 | +| Figure 8.2.2.2-1: RIC Subscription Delete procedure, successful operation ..... | 18 | +| Figure 8.2.2.3-1: RIC Subscription Delete procedure, unsuccessful operation ..... | 18 | +| Figure 8.2.2A.2-1: RIC Subscription Delete Required procedure, successful operation ..... | 19 | +| Figure 8.2.2B.2-1: RIC Subscription Audit procedure, successful operation ..... | 20 | +| Figure 8.2.2B.3-1: RIC Subscription Audit procedure, unsuccessful operation ..... | 21 | +| Figure 8.2.3.2-1: RIC Indication procedure, successful operation ..... | 22 | +| Figure 8.2.4.2-1: RIC Control procedure, successful operation ..... | 23 | +| Figure 8.2.4.3-1: RIC Control procedure, unsuccessful operation ..... | 24 | +| Figure 8.2.5.2-1: RIC Subscription Modification procedure, successful operation ..... | 25 | +| Figure 8.2.5.3-1: RIC Subscription Modification procedure, unsuccessful operation ..... | 27 | +| Figure 8.2.6.2-1: RIC Subscription Modification Required procedure, successful operation ..... | 28 | +| Figure 8.2.6.3-1: RIC Subscription Modification Required procedure, unsuccessful operation ..... | 29 | +| Figure 8.2.7.2-1: RIC Query procedure, successful operation ..... | 30 | +| Figure 8.2.7.3-1: RIC Query procedure, unsuccessful operation ..... | 30 | +| Figure 8.2.8.2-1: RIC Load Status procedure, successful operation ..... | 31 | +| Figure 8.2.8.3-1: RIC Service Load Status procedure, unsuccessful operation ..... | 32 | +| Figure 8.2.9.2-1: RIC Service Load Update procedure, successful operation ..... | 33 | +| Figure 8.2.10.2-1: RIC Subscription State Control procedure, successful operation ..... | 34 | +| Figure 8.2.10.3-1: RIC Subscription State Control procedure, unsuccessful operation ..... | 35 | +| Figure 8.2.11.2-1: RIC Assistance procedure, successful operation ..... | 35 | +| Figure 8.2.11.3-1: RIC Assistance procedure, unsuccessful operation ..... | 36 | +| Figure 8.2.12.2-1: RIC Assistance Indication procedure, successful operation ..... | 37 | +| Figure 8.2.13.2-1: RIC Assistance Halt procedure, successful operation ..... | 38 | +| Figure 8.3.1.2-1: E2 Setup procedure, successful operation ..... | 39 | +| Figure 8.3.1.3-1: E2 Setup procedure, unsuccessful operation ..... | 39 | +| Figure 8.3.2.2-1: Reset, successful operation (E2 Node Initiated) ..... | 40 | +| Figure 8.3.2.2-2: Reset, successful operation (Near-RT RIC Initiated) ..... | 40 | +| Figure 8.3.3.2-1: Error Indication, (E2 Node initiated) successful operation ..... | 41 | +| Figure 8.3.3.2-2: Error Indication, (Near-RT RIC Initiated) successful operation ..... | 41 | +| Figure 8.3.4.2-1: RIC Service Update procedure, successful operation ..... | 42 | +| Figure 8.3.4.3-1: RIC Service Update procedure, unsuccessful operation ..... | 43 | +| Figure 8.3.4A.2-1: RIC Service Query procedure, successful operation ..... | 44 | +| Figure 8.3.5.2-1: E2 Node Configuration Update procedure, successful operation ..... | 45 | +| Figure 8.3.5.3-1: E2 Node Configuration Update procedure, unsuccessful operation ..... | 46 | +| Figure 8.3.6.2-1: E2 Connection Update procedure, successful operation ..... | 47 | +| Figure 8.3.6.3-1: E2 Connection Update procedure, unsuccessful operation ..... | 48 | +| Figure 8.3.7.2-1: E2 Removal, successful operation (E2 Node Initiated) ..... | 49 | +| Figure 8.3.7.2-2: E2 Removal, successful operation (Near-RT RIC Initiated) ..... | 49 | +| Figure 8.3.7.3-1: E2 Removal procedure (E2 Node Initiated), unsuccessful operation ..... | 50 | +| Figure 8.3.7.3-2: E2 Removal procedure (Near-RT RIC Initiated), unsuccessful operation ..... | 50 | + +# List of tables + +| | | +|--------------------------------------------------|----| +| Table 8.1-1: Class 1 Elementary Procedures ..... | 14 | +| Table 8.1-2: Class 2 Elementary Procedures ..... | 15 | + + + +# --- Foreword + +This Technical Specification (TS) has been produced by WG3 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the Near-RT RIC layer signalling protocol for the E2 interface. + +The E2 interface provides means for interconnecting a Near-RT RIC and an E2 Node. The E2 Application Protocol (E2AP) supports the functions of E2 interface by signalling procedures defined in the present document. E2AP is developed in accordance with the general principles stated in O-RAN WG3.TS.E2GAP [2]. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +The following referenced documents are necessary for the application of the present document. + +- | | | +|------|--------------------------------------------------------------------------------------------------------------------------------------| +| [1] | Void. | +| [2] | O-RAN WG3.TS.E2GAP: "O-RAN E2 General Aspects and Principles (E2GAP)". | +| [3] | O-RAN WG3.TS.E2SM: "O-RAN E2 Service Model (E2SM)". | +| [4] | Void. | +| [5] | Void. | +| [6] | Void. | +| [7] | Void. | +| [8] | Void. | +| [9] | Void. | +| [10] | Void. | +| [11] | Void. | +| [12] | Void. | +| [13] | Void. | +| [14] | Void. | +| [15] | Recommendation ITU-T X.691 (02/2021): "Information technology – ASN.1 encoding rules: Specification of Packed Encoding Rules (PER)". | + +- [16] Recommendation ITU-T X.680 (02/2021): "Information technology – Abstract Syntax Notation One (ASN.1): Specification of basic notation". +- [17] Recommendation ITU-T X.681 (02/2021): "Information technology – Abstract Syntax Notation One (ASN.1): Information object specification". +- [18] Void. +- [19] 3GPP TS 38.413: "NG-RAN; NG Application Protocol (NGAP)" +- [20] 3GPP TS 38.423: "NG-RAN; Xn application protocol (XnAP)" +- [21] 3GPP TS 37.483: "E1 Application Protocol (E1AP)" +- [22] 3GPP TS 38.473: "NG-RAN; F1 application protocol (F1AP)" +- [23] 3GPP TS 37.473: "W1 interface; Application Protocol (W1AP)" +- [24] 3GPP TS 36.413: "Evolved Universal Terrestrial Radio Access Network (E-UTRAN); S1 Application Protocol (S1AP)" +- [25] 3GPP TS 36.423: "Evolved Universal Terrestrial Radio Access Network (E-UTRAN); X2 application protocol (X2AP) " +- [26] IETF RFC 5905: "Network Time Protocol Version 4: Protocol and Algorithms Specification" +- [27] O-RAN WG1.TS.OAD: "O-RAN Architecture Description" + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [i.2] 3GPP TS 25.921 (version 7.0.0): "Guidelines and principles for protocol description and error handling". + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in 3GPP TR 21.905 [i.1], O-RAN WG1.TS.OAD [27], O-RAN WG3.TS.E2GAP [2] and the following apply. + +NOTE: A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [i.1], O-RAN WG1.TS.OAD [27] and O-RAN WG3.TS.E2GAP [2]. + +**E2 Node Component ID:** local identifier used to uniquely identify an E2 Node component + +**Elementary Procedure:** E2AP protocol consists of Elementary Procedures (EPs) + +NOTE: An E2AP Elementary Procedure is a unit of interaction between the Near-RT RIC and an E2 Node. An EP consists of an initiating message and possibly a response message. Two kinds of EPs are used: + +Class 1: Elementary Procedures with response (success or failure), + +Class 2: Elementary Procedures without response. + +**Global E2 Node ID:** global identifier of an E2 Node. Defined as the global eNB or gNB identifier and an optional local identifier of an CU-UP or DU which is required when and if an individual DU or CU-UP supports a direct E2 interface + +**Global RIC ID:** global identifier of a Near-RT RIC + +**RAN Function ID:** local identifier of a specific RAN Function within an E2 Node that supports one or more RIC Services using a specific E2 Service Model + +**RAN Function OID:** RAN Function Object Identifier used to identify specific RAN function definition (i.e. E2SM used by specific RAN Function) + +**RIC Action ID:** local identifier used Near-RT RIC to identify a specific RIC Service Action within a specific RIC Subscription Request, used by E2 Node in subsequent RIC Indication messages + +**RIC Call Process ID:** local identifier used by E2 Node to identify the associated procedure during an Insert RIC Service Action, used by Near-RT RIC in subsequent RIC Control procedure + +**RIC Request ID:** local identifier used to identify a specific RIC Functional procedure among all ongoing parallel procedures of the same type initiated by the same protocol peer. + +NOTE: Messages belonging to the same procedure use the same RIC Request ID. The RIC Request ID is determined by the initiating peer of a RIC Functional Procedure. + +**Transaction ID:** local identifier used to uniquely identify a Global Procedure among all ongoing parallel procedures of the same type initiated by the same protocol peer + +NOTE: Messages belonging to the same procedure use the same Transaction ID. The Transaction ID is determined by the initiating peer of a Global Procedure (Near-RT RIC or E2 Node). + +## 3.2 Symbols + +Void. + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [i.1], O-RAN WG1.TS.OAD [27] and the following apply. + +NOTE: An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [i.1] and O-RAN WG1.TS.OAD [27]. + +| | | +|----|----------------------| +| EP | Elementary Procedure | +|----|----------------------| + +# 4 General + +## 4.1 Procedure specification principles + +The principle for specifying the procedure logic is to specify the functional behaviour of the terminating node exactly and completely. Any rule that specifies the behaviour of the originating node shall be possible to be verified with information that is visible within the system. + +The following specification principles have been applied for the procedure text in clause 8: + +- The procedure text discriminates between: + - 1) Functionality which "shall" be executed. + + +The procedure text indicates that the receiving node "shall" perform a certain function Y under a certain condition. If the receiving node supports procedure X but cannot perform functionality Y requested in the REQUEST message of a Class 1 EP, the receiving node shall respond with the message used to report unsuccessful outcome for this procedure, containing an appropriate cause value. + - 2) Functionality which "shall, if supported" be executed. + + +The procedure text indicates that the receiving node "shall, if supported," perform a certain function Y under a certain condition. If the receiving node supports procedure X, but does not support functionality Y, the receiving node shall proceed with the execution of the EP, possibly informing the requesting node about the nonsupported functionality. +- Any required inclusion of an optional IE in a response message is explicitly indicated in the procedure text. If the procedure text does not explicitly indicate that an optional IE shall be included in a response message, the optional IE shall not be included. For requirements on including Criticality Diagnostics IE, see clause 10. + +## 4.2 Forwards and backwards compatibility + +The forwards and backwards compatibility of the protocol is assured by mechanism where all current and future messages, and IEs or groups of related IEs, include ID and criticality fields that are coded in a standard format that will not be changed in the future. These parts can always be decoded regardless of the standard version. + +## 4.3 Specification notations + +For the purposes of the present document, the following notations apply: + +| | | +|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Procedure | When referring to an Elementary Procedure (EP) in the present document the Procedure Name is written with the first letters in each word in upper case characters followed by the word "procedure", e.g. Handover Preparation procedure. | +| Message | When referring to a message in the present document the MESSAGE NAME is written with all letters in upper case characters followed by the word "message", e.g. HANDOVER REQUEST message. | +| IE | When referring to an Information Element (IE) in the present document the <i>Information Element Name</i> is written with the first letters in each word in upper case characters and all letters in Italic font followed by the abbreviation "IE", e.g. <i>E-RAB ID</i> IE. | +| Value of an IE | When referring to the value of an Information Element (IE) in the present document the "Value" is written as it is specified in the present document enclosed by quotation marks, e.g. "Value". | + +# --- 5 E2AP Services + +## 5.1 E2AP procedure modules + +The E2 interface E2AP procedures are divided into two modules as follows: + +1. RIC Functional Procedures; +2. Global Procedures. + +The RIC functional procedures module contains procedures used to pass application specific messages between Near-RT RIC applications and a target RAN Function in an E2 node as specified in O-RAN WG3.TS.E2GAP [2]. + +The Global Procedures module contains procedures that are not directly related to a specific application. + +## 5.2 Parallel transactions + +Parallel transactions, that is, multiple ongoing E2AP procedures related to the same Application and E2 node, are supported. + +# --- 6 Services expected from signalling transport + +The signalling connection shall provide in sequence delivery of E2AP messages. E2AP shall be notified if the signalling connection breaks. + +# --- 7 Functions of E2AP + +The functions of E2AP are described in O-RAN WG3.TS.E2GAP [2]. + +# --- 8 E2AP procedures + +## 8.1 Elementary procedures + +In the Tables 8.1-1 and 8.1-2, all EPs are divided into Class 1 and Class 2 EPs. + +Table 8.1-1: Class 1 Elementary Procedures + +| Initiated by | Elementary Procedure | Initiating Message | Successful Outcome Response message | Unsuccessful Outcome Response message | +|------------------------|----------------------------------------|----------------------------------------|------------------------------------------|----------------------------------------| +| Near-RT RIC | RIC Subscription | RIC SUBSCRIPTION REQUEST | RIC SUBSCRIPTION RESPONSE | RIC SUBSCRIPTION FAILURE | +| Near-RT RIC | RIC Subscription Delete | RIC SUBSCRIPTION DELETE REQUEST | RIC SUBSCRIPTION DELETE RESPONSE | RIC SUBSCRIPTION DELETE FAILURE | +| Near-RT RIC | RIC Subscription Modification | RIC SUBSCRIPTION MODIFICATION REQUEST | RIC SUBSCRIPTION MODIFICATION RESPONSE | RIC SUBSCRIPTION MODIFICATION FAILURE | +| E2 Node | RIC Subscription Modification Required | RIC SUBSCRIPTION MODIFICATION REQUIRED | RIC SUBSCRIPTION MODIFICATION CONFIRM | RIC SUBSCRIPTION MODIFICATION REFUSE | +| Near-RT RIC | RIC Subscription State Control | RIC SUBSCRIPTION STATE CONTROL REQUEST | RIC SUBSCRIPTION STATE CONTROL RESPONSE | RIC SUBSCRIPTION STATE CONTROL FAILURE | +| Near-RT RIC | RIC Subscription Audit | RIC SUBSCRIPTION AUDIT REQUEST | RIC SUBSCRIPTION AUDIT RESPONSE | RIC SUBSCRIPTION AUDIT FAILURE | +| E2 Node | RIC Assistance | RIC ASSISTANCE REQUEST | RIC ASSISTANCE RESPONSE | RIC ASSISTANCE FAILURE | +| Near-RT RIC | RIC Control | RIC CONTROL REQUEST | RIC CONTROL ACKNOWLEDGE | RIC CONTROL FAILURE | +| Near-RT RIC | RIC Query | RIC QUERY REQUEST | RIC QUERY RESPONSE | RIC QUERY FAILURE | +| Near-RT RIC | RIC Service Load Status | RIC SERVICE LOAD STATUS REQUEST | RIC SERVICE LOAD STATUS RESPONSE | RIC SERVICE LOAD STATUS FAILURE | +| E2 Node | E2 Setup | E2 SETUP REQUEST | E2 SETUP RESPONSE | E2 SETUP FAILURE | +| E2 Node | RIC Service Update | RIC SERVICE UPDATE | RIC SERVICE UPDATE ACKNOWLEDGE | RIC SERVICE UPDATE FAILURE | +| E2 Node | E2 Node Configuration Update | E2 NODE CONFIGURATION UPDATE | E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE | E2 NODE CONFIGURATION UPDATE FAILURE | +| Near-RT RIC | E2 Connection Update | E2 CONNECTION UPDATE | E2 CONNECTION UPDATE ACKNOWLEDGE | E2 CONNECTION UPDATE FAILURE | +| Near-RT RIC or E2 Node | Reset | RESET REQUEST | RESET RESPONSE | | +| Near-RT RIC or E2 Node | E2 Removal | E2 REMOVAL REQUEST | E2 REMOVAL RESPONSE | E2 REMOVAL FAILURE | + +**Table 8.1-2: Class 2 Elementary Procedures** + +| Initiated by | Elementary Procedure | Initiating Message | +|------------------------|----------------------------------|----------------------------------| +| Near-RT RIC | RIC Assistance Indication | RIC ASSISTANCE INDICATION | +| E2 Node | RIC Assistance Halt | RIC ASSISTANCE HALT | +| E2 Node | RIC Indication | RIC INDICATION | +| Near-RT RIC | RIC Service Query | RIC SERVICE QUERY | +| E2 Node | RIC Subscription Delete Required | RIC SUBSCRIPTION DELETE REQUIRED | +| E2 Node | RIC Service Load Update | RIC SERVICE LOAD UPDATE | +| E2 Node or Near-RT RIC | Error Indication | ERROR INDICATION | + +## 8.2 RIC Functional procedures + +### 8.2.1 RIC Subscription procedure + +#### 8.2.1.1 General + +This procedure is used to establish RIC Subscriptions on E2 Node consisting of an event trigger and a sequence of RIC Service Actions. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses RIC Service signalling. + +#### 8.2.1.2 Successful operation + +![Sequence diagram showing the RIC Subscription procedure, successful operation. The diagram shows two instances of 'Near-RT RIC' and two instances of 'E2 Node'. A message 'RIC SUBSCRIPTION REQUEST' is sent from the top 'Near-RT RIC' to the top 'E2 Node'. A message 'RIC SUBSCRIPTION RESPONSE' is sent from the top 'E2 Node' to the bottom 'Near-RT RIC'.](a46604d3bdae30b813025088d10b722c_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + N1->>E1: RIC SUBSCRIPTION REQUEST + E1-->>N2: RIC SUBSCRIPTION RESPONSE + +``` + +Sequence diagram showing the RIC Subscription procedure, successful operation. The diagram shows two instances of 'Near-RT RIC' and two instances of 'E2 Node'. A message 'RIC SUBSCRIPTION REQUEST' is sent from the top 'Near-RT RIC' to the top 'E2 Node'. A message 'RIC SUBSCRIPTION RESPONSE' is sent from the top 'E2 Node' to the bottom 'Near-RT RIC'. + +**Figure 8.2.1.2-1: RIC Subscription procedure, successful operation** + +The Near-RT RIC initiates the procedure by sending a RIC SUBSCRIPTION REQUEST message, which shall contain a unique *RIC Request ID* IE, assigned by the Near-RT RIC, to the E2 Node. + +When the Near-RT RIC sends the RIC SUBSCRIPTION REQUEST message, it shall start the timer $T_{RICEVENTcreate}$ . + +At reception of the RIC SUBSCRIPTION REQUEST message the E2 Node shall: + +- Determine the target RAN Function using the information in the *RAN Function ID* IE and configure the requested event trigger using information in the *RIC Subscription Details* IE. + +- If one or more Report, Insert and/or Policy RIC Service Actions are included in the *RIC Subscription Details* IE then the target RAN Function shall validate the event trigger and requested action sequence and, if accepted, store the required *RIC Request ID*, *RIC Event Trigger Definition* IE and sequence of RIC Service Actions. +- If optional *RIC Subscription Start Time* IE is present and has expired, then the E2 Node shall ignore the optional *RIC Subscription Start Time* IE. + +If the requested trigger and at least one required RIC Service Action are accepted by the E2 Node, the E2 Node shall reserve for each admitted RIC Service Action the necessary resources and send the RIC SUBSCRIPTION RESPONSE message back to the Near-RT RIC. + +The E2 Node shall include in the response message the RIC Service Actions for which resources have been prepared at the E2 Node in the *RIC Actions Admitted List* IE. + +The E2 Node shall include the RIC Service Actions that have not been admitted in the *RIC Actions Not Admitted List* IE with an appropriate cause value. + +Upon reception of the RIC SUBSCRIPTION RESPONSE message the Near-RT RIC shall stop timer $T_{RICEVENTcreate}$ and terminate the RIC Subscription procedure. + +If more than one RIC Service Actions has been accepted by the E2 Node then, at each occurrence of the common Event Trigger, the sequence of RIC Service Actions shall be executed according to the following considerations: + +- If optional *RIC Action Execution Order* IE is not present or is present and set to 0 ("Any order"), then the specific RIC Service Action in the sequence of RIC Service Actions may be executed in any order irrespective of the execution order of the other RIC Service Actions. +- If optional *RIC Action Execution Order* IE is present and set to a value greater than 0, then the specific RIC Service Action shall be executed in order according to the *RIC Action Execution Order* IE. +- If two or more RIC Service Actions have the same value for the optional *RIC Action Execution Order* IE then these RIC Service Actions shall be executed in parallel. + +If the optional *RIC Subscription Start Time* IE is present, the E2 Node shall only enable the event trigger from the indicated start time. + +If the optional *RIC Subscription End Time* IE is present, the E2 Node shall disable the event trigger when the indicated end time has expired. + +##### **Interactions with RIC Subscription Delete Required procedure:** + +If the optional *RIC Subscription End Time* IE is present and the indicated end time has expired, the E2 Node may send the RIC SUBSCRIPTION DELETE REQUIRED message to the Near-RT RIC with an appropriate cause value. + +##### **Interactions with RIC Subscription Delete procedure:** + +If the optional *RIC Subscription End Time* IE is present, the Near-RT RIC may initiate an RIC Subscription Delete procedure when the expected *RIC Subscription End Time* has expired. + +#### 8.2.1.3 Unsuccessful operation + +![Sequence diagram showing the unsuccessful RIC Subscription procedure. A Near-RT RIC sends a RIC SUBSCRIPTION REQUEST to an E2 Node. The E2 Node responds with a RIC SUBSCRIPTION FAILURE message back to the Near-RT RIC.](423a557532703319d8c5524560cb5fbe_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Near-RT RIC->>E2 Node: RIC SUBSCRIPTION REQUEST + E2 Node->>Near-RT RIC: RIC SUBSCRIPTION FAILURE + +``` + +Sequence diagram showing the unsuccessful RIC Subscription procedure. A Near-RT RIC sends a RIC SUBSCRIPTION REQUEST to an E2 Node. The E2 Node responds with a RIC SUBSCRIPTION FAILURE message back to the Near-RT RIC. + +**Figure 8.2.1.3-1: RIC Subscription procedure, unsuccessful operation** + +If a failure occurs during the RIC Subscription procedure the E2 Node shall send the RIC SUBSCRIPTION FAILURE message to the Near-RT RIC containing an appropriate cause value. + +If the E2 Node admits none of the requested RIC Service Actions, or detects an issue with the requested sequence of RIC Service Actions, or in the optional *RIC Subsequent Action* IE definitions, the E2 Node shall send the RIC SUBSCRIPTION FAILURE message to the Near-RT RIC containing an appropriate cause value. + +If the RIC Subscription procedure contains an invalid optional *RIC Subscription Start Time* IE and/or *RIC Subscription End Time* IE, the E2 Node shall send the RIC SUBSCRIPTION FAILURE message to the Near-RT RIC containing an appropriate cause value. + +Upon reception of the RIC SUBSCRIPTION FAILURE message the Near-RT RIC shall stop the timer $T_{\text{RICcreate}}$ and terminate the RIC Subscription procedure. + +##### Interactions with RIC Subscription Delete procedure: + +If there is no response from the E2 Node to the RIC SUBSCRIPTION REQUEST message before timer $T_{\text{RICcreate}}$ expires in the Near-RT RIC, the Near-RT RIC shall initiate the RIC Subscription Delete procedure containing *RIC Request ID* IE that was previously assigned by the Near-RT RIC to cancel the RIC Subscription towards the E2 Node. The Near-RT RIC shall ignore any RIC SUBSCRIPTION RESPONSE or RIC SUBSCRIPTION FAILURE message containing *RIC Request ID* IE that was previously assigned by the Near-RT RIC received after the initiation of the RIC Subscription Delete procedure and release any resources related to the concerned E2 Node. + +#### 8.2.1.4 Abnormal conditions + +### 8.2.2 RIC Subscription Delete procedure + +#### 8.2.2.1 General + +This procedure is used to delete RIC Subscriptions on E2 Node. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses RIC Service signalling. + +#### 8.2.2.2 Successful operation + +![Sequence diagram for successful RIC Subscription Delete procedure](63061e2677d6286caee26e8886bc5d08_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Near-RT RIC->>E2 Node: RIC SUBSCRIPTION DELETE REQUEST + E2 Node->>Near-RT RIC: RIC SUBSCRIPTION DELETE RESPONSE + +``` + +The diagram illustrates the successful operation of the RIC Subscription Delete procedure. It shows the Near-RT RIC sending a 'RIC SUBSCRIPTION DELETE REQUEST' message to the E2 Node, and the E2 Node responding with a 'RIC SUBSCRIPTION DELETE RESPONSE' message. + +Sequence diagram for successful RIC Subscription Delete procedure + +**Figure 8.2.2.2-1: RIC Subscription Delete procedure, successful operation** + +The Near-RT RIC initiates the procedure by sending a RIC SUBSCRIPTION DELETE REQUEST message, containing *RIC Request ID* IE that was previously assigned by the Near-RT RIC during a successful RIC Subscription procedure, to the E2 Node. + +When the Near-RT RIC sends the RIC SUBSCRIPTION DELETE REQUEST message, it shall start timer $T_{\text{RICEVENTdelete}}$ . + +At reception of the RIC SUBSCRIPTION DELETE REQUEST message the E2 Node shall delete the indicated RIC Subscription and release the corresponding necessary resources. + +The E2 Node shall send the RIC SUBSCRIPTION DELETE RESPONSE message back to the Near-RT RIC. + +Upon reception of the RIC SUBSCRIPTION DELETE RESPONSE message the Near-RT RIC shall stop timer $T_{\text{RICEVENTdelete}}$ , release any necessary resources associated with that RIC Subscription and terminate the RIC Subscription Delete procedure. + +#### 8.2.2.3 Unsuccessful operation + +![Sequence diagram for unsuccessful RIC Subscription Delete procedure](68d6201add786997d64525e3d9686a83_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Near-RT RIC->>E2 Node: RIC SUBSCRIPTION DELETE REQUEST + E2 Node->>Near-RT RIC: RIC SUBSCRIPTION DELETE FAILURE + +``` + +The diagram illustrates the unsuccessful operation of the RIC Subscription Delete procedure. It shows the Near-RT RIC sending a 'RIC SUBSCRIPTION DELETE REQUEST' message to the E2 Node, and the E2 Node responding with a 'RIC SUBSCRIPTION DELETE FAILURE' message. + +Sequence diagram for unsuccessful RIC Subscription Delete procedure + +**Figure 8.2.2.3-1: RIC Subscription Delete procedure, unsuccessful operation** + +If a failure occurs during the RIC Subscription Delete procedure, the E2 Node shall send the RIC SUBSCRIPTION DELETE FAILURE message to the Near-RT RIC containing an appropriate cause value. + +If the *RIC Request ID* IE included in the RIC SUBSCRIPTION DELETE REQUEST message is unknown, the E2 Node shall send the RIC SUBSCRIPTION DELETE FAILURE message to the Near-RT RIC containing an appropriate cause value + +Upon reception of the RIC SUBSCRIPTION DELETE FAILURE message the Near-RT RIC shall stop timer $T_{\text{RICEVENTdelete}}$ and terminate the RIC Subscription Delete procedure. + +#### 8.2.2.4 Abnormal conditions + +If the E2 Node receives a RIC SUBSCRIPTION DELETE REQUEST message contains an unknown *RAN Function ID* IE, the E2 Node shall send the RIC SUBSCRIPTION DELETE FAILURE message to the Near-RT RIC containing an appropriate cause value. + +### 8.2.2A RIC Subscription Delete Required procedure + +#### 8.2.2A.1 General + +This procedure is used to enable the E2 Node to request deletion of the existing RIC Subscriptions in the E2 Node previously created for the Near-RT RIC. + +This procedure shall be initiated by the E2 Node. + +This procedure uses RIC Service signalling. + +#### 8.2.2A.2 Successful operation + +![Sequence diagram showing the RIC Subscription Delete Required procedure. The E2 Node sends a 'RIC SUBSCRIPTION DELETE REQUIRED' message to the Near-RT RIC. The Near-RT RIC then initiates the 'RIC Subscription Delete procedure' back towards the E2 Node.](a62d44a3d5bd1b617b68abec7cccbb13_img.jpg) + +``` + +sequenceDiagram + participant E2 as E2 Node + participant Near-RT as Near-RT RIC + E2->>Near-RT: RIC SUBSCRIPTION DELETE REQUIRED + Note over Near-RT: RIC Subscription Delete procedure + Near-RT-->>E2: + +``` + +Sequence diagram showing the RIC Subscription Delete Required procedure. The E2 Node sends a 'RIC SUBSCRIPTION DELETE REQUIRED' message to the Near-RT RIC. The Near-RT RIC then initiates the 'RIC Subscription Delete procedure' back towards the E2 Node. + +**Figure 8.2.2A.2-1: RIC Subscription Delete Required procedure, successful operation** + +The E2 Node initiates the procedure by sending a RIC SUBSCRIPTION DELETE REQUIRED message, containing *RIC Request ID* IE that was previously assigned by the Near-RT RIC during a successful RIC Subscription procedure, to the Near-RT RIC. + +The message shall contain an appropriate cause value for each RIC Subscription requesting to remove. + +At reception of the RIC SUBSCRIPTION DELETE REQUIRED message, for each RIC Subscription associated with the included *RIC Request ID* IE and *RAN Function ID* IE, the Near-RT RIC may initiate the RIC Subscription Delete procedure toward the E2 Node. + +#### 8.2.2A.3 Abnormal conditions + +If the Near-RT RIC receives a RIC SUBSCRIPTION DELETE REQUIRED message which contains an unknown *RIC Request ID* IE and *RAN Function ID* IE, the Near-RT RIC shall ignore the message. + +### 8.2.2B RIC Subscription Audit procedure + +#### 8.2.2B.1 General + +This procedure is used to audit the list of establish RIC Subscriptions on E2 Node. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses RIC Service signalling. + +#### 8.2.2B.2 Successful operation + +![Sequence diagram showing the RIC Subscription Audit procedure. A Near-RT RIC sends a RIC SUBSCRIPTION AUDIT REQUEST to an E2 Node, and the E2 Node responds with a RIC SUBSCRIPTION AUDIT RESPONSE.](4d74c95402ccff1aee1004335fb98f94_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + N1-->>E1: RIC SUBSCRIPTION AUDIT REQUEST + E1-->>N2: RIC SUBSCRIPTION AUDIT RESPONSE + +``` + +Sequence diagram showing the RIC Subscription Audit procedure. A Near-RT RIC sends a RIC SUBSCRIPTION AUDIT REQUEST to an E2 Node, and the E2 Node responds with a RIC SUBSCRIPTION AUDIT RESPONSE. + +**Figure 8.2.2B.2-1: RIC Subscription Audit procedure, successful operation** + +The Near-RT RIC initiates the procedure by sending a RIC SUBSCRIPTION AUDIT REQUEST message which shall contain a unique *RIC Request ID* IE, assigned by the Near-RT RIC to identify the procedure, and may contain the *RIC Subscription Audit List* IE with each item containing a *RIC Request ID* IE, that was previously assigned by the Near-RT RIC during a successful RIC Subscription procedure, to the E2 Node. + +When the Near-RT RIC sends the RIC SUBSCRIPTION AUDIT REQUEST message, it shall start the timer $T_{\text{RICEVENTcreate}}$ . + +At reception of the RIC SUBSCRIPTION AUDIT REQUEST message the E2 Node shall: + +- If the *RIC Subscription Audit List* IE is present and contains at least one RIC Subscription, identified by the *RIC Request ID* IE, that is recognized by the E2 Node, then the E2 Node shall record the confirmed RIC Subscriptions in the *RIC Subscription Confirmed List* IE. +- If the *RIC Subscription Audit List* IE is present and contains at least one RIC Subscription, identified by the *RIC Request ID* IE, that is not known to the E2 Node, then the E2 Node shall record the unknown RIC Subscriptions in the *RIC Subscription Unknown List* IE. +- If the *RIC Subscription Audit List* IE is present and if the *RIC Subscription Audit Flag* IE is not present and the E2 Node holds at least one established RIC Subscription that is not included in the *RIC Subscription Audit List* IE, then the E2 Node shall record the missing RIC Subscriptions in the *RIC Subscription Missing List* IE. +- If the *RIC Subscription Audit List* IE is present and if the *RIC Subscription Audit Flag* IE is present and the *Listed Records Only* IE is present and set to TRUE, then the E2 Node shall only respond with respect to the RIC Subscriptions in the *RIC Subscription Audit List* IE. + +- If the *RIC Subscription Audit List IE* is not present, then the E2 Node shall record all established RIC Subscriptions in the *RIC Subscription Missing List IE*. + +After processing the RIC SUBSCRIPTION AUDIT REQUEST message, if the E2 Node has at least one item in *RIC Subscription Confirmed List IE*, *RIC Subscription Unknown List IE* or *RIC Subscription Missing List IE*, the E2 Node shall send the RIC SUBSCRIPTION AUDIT RESPONSE message back to the Near-RT RIC. + +The E2 Node shall include in the response message the confirmed RIC Subscriptions in the *RIC Subscription Confirmed List IE*. + +The E2 Node shall include in the response message the not known RIC Subscriptions in the *RIC Subscription Unknown List IE*. + +The E2 Node shall include in the response message the missing RIC Subscriptions in the *RIC Subscription Missing List IE*. + +Upon reception of the RIC SUBSCRIPTION AUDIT RESPONSE message the Near-RT RIC shall stop timer T<sub>RICEVENTcreate</sub> and terminate the RIC Subscription Audit procedure. + +#### 8.2.2B.3 Unsuccessful operation + +![Sequence diagram showing the unsuccessful RIC Subscription Audit procedure. A Near-RT RIC sends a RIC SUBSCRIPTION AUDIT REQUEST to an E2 Node. The E2 Node responds with a RIC SUBSCRIPTION AUDIT FAILURE message.](a8cff121ed47c877b9b6e30c21d09225_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Near-RT RIC->>E2 Node: RIC SUBSCRIPTION AUDIT REQUEST + E2 Node-->>Near-RT RIC: RIC SUBSCRIPTION AUDIT FAILURE + +``` + +Sequence diagram showing the unsuccessful RIC Subscription Audit procedure. A Near-RT RIC sends a RIC SUBSCRIPTION AUDIT REQUEST to an E2 Node. The E2 Node responds with a RIC SUBSCRIPTION AUDIT FAILURE message. + +**Figure 8.2.2B.3-1: RIC Subscription Audit procedure, unsuccessful operation** + +If a failure occurs during the RIC Subscription Audit procedure the E2 Node shall send the RIC SUBSCRIPTION AUDIT FAILURE message to the Near-RT RIC containing an appropriate cause value. + +If the E2 Node after processing the RIC SUBSCRIPTION AUDIT REQUEST message, the E2 Node does not have at least one item in *RIC Subscription Confirmed List IE*, *RIC Subscription Unknown List IE* or *RIC Subscription Missing List IE*, the E2 Node shall send the RIC SUBSCRIPTION AUDIT FAILURE message to the Near-RT RIC containing an appropriate cause value. + +Upon reception of the RIC SUBSCRIPTION AUDIT FAILURE message the Near-RT RIC shall stop the timer T<sub>RICEVENTcreate</sub> and terminate the RIC Subscription procedure. + +#### 8.2.2B.4 Abnormal conditions + +If the E2 Node receives a RIC SUBSCRIPTION AUDIT REQUEST message which contains an unknown *RAN Function ID IE*, the E2 Node shall send the RIC SUBSCRIPTION AUDIT FAILURE message to the Near-RT RIC containing an appropriate cause value. + +### 8.2.3 RIC Indication procedure + +#### 8.2.3.1 General + +The purpose of the RIC Indication procedure is to transfer Report and/or Insert RIC Service Action associated with a RIC Subscription procedure. + +This procedure shall be initiated by the E2 Node. + +This procedure uses RIC Service signalling. + +#### 8.2.3.2 Successful operation + +![Diagram illustrating the RIC Indication procedure, successful operation. It shows two rows of boxes. The top row contains 'Near-RT RIC' and 'E2 Node'. The bottom row contains 'Near-RT RIC' and 'E2 Node'. A red arrow labeled 'RIC INDICATION' points from the 'E2 Node' box in the top row to the 'Near-RT RIC' box in the bottom row. Dashed lines connect the 'Near-RT RIC' boxes and the 'E2 Node' boxes vertically.](58d512af60456c43a2714b54d865ecec_img.jpg) + +Diagram illustrating the RIC Indication procedure, successful operation. It shows two rows of boxes. The top row contains 'Near-RT RIC' and 'E2 Node'. The bottom row contains 'Near-RT RIC' and 'E2 Node'. A red arrow labeled 'RIC INDICATION' points from the 'E2 Node' box in the top row to the 'Near-RT RIC' box in the bottom row. Dashed lines connect the 'Near-RT RIC' boxes and the 'E2 Node' boxes vertically. + +**Figure 8.2.3.2-1: RIC Indication procedure, successful operation** + +An E2 Node initiates the procedure by sending RIC INDICATION message to the Near-RT RIC containing the *RIC Request ID* IE, that was previously assigned by the Near-RT RIC during a successful RIC Subscription procedure. + +If the RIC Indication message is in response to an Insert RIC Service Action, then the E2 Node shall provide the *RIC Call Process ID* IE within the RIC INDICATION message, and the E2 Node shall start the associated *RIC Time to Wait* timer, and wait for the corresponding response from the Near-RT RIC. + +Near-RT RIC may use the *RIC Call Process ID* IE in a subsequent RIC Control procedure. + +If an *RIC Subsequent Action* IE was associated to the RIC Service Action then, after successful transmission of the RIC INDICATION message, the originating E2 Node shall progress accordingly: + +- If the *RIC Subsequent Action Type* IE was set to Continue or Halt, and the associated *RIC Time to Wait* timer has not expired, and a RIC CONTROL REQUEST message is received with the same *RIC Call Process ID* IE, then the associated procedure shall process the RIC CONTROL REQUEST and continue to execute any remaining actions in the sequence of RIC Actions defined in the RIC Subscription procedure. +- If the *RIC Subsequent Action Type* IE was set to Continue and the associated *RIC Time to Wait* timer has expired, then the E2 Node shall continue to execute any remaining RIC Service Actions in the sequence of RIC Service Actions defined in the RIC Subscription procedure. +- If the *RIC Subsequent Action Type* IE was set to Halt and the associated *RIC Time to Wait* timer has expired, then the E2 Node shall abort further processing of the associated procedure in the E2 node. In this case, any remaining or ongoing parallel RIC Service Actions in the sequence of RIC Actions defined in the RIC Subscription procedure shall also be aborted. + +#### 8.2.3.3 Unsuccessful operation + +Not applicable. + +#### 8.2.3.4 Abnormal conditions + +Not applicable. + +### 8.2.4 RIC Control procedure + +#### 8.2.4.1 General + +The purpose of the RIC Control procedure is to initiate or resume a specific functionality in the E2 Node. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses RIC Service signalling. + +#### 8.2.4.2 Successful operation + +![Sequence diagram showing the RIC Control procedure, successful operation. The diagram illustrates the interaction between a Near-RT RIC and an E2 Node. The Near-RT RIC sends a RIC CONTROL REQUEST message to the E2 Node. The E2 Node responds with a RIC CONTROL ACKNOWLEDGE message. The diagram shows two instances of each entity, with the top instance representing the initial state and the bottom instance representing the state after the procedure.](7eb2577b5e262b911d748cd6229145ad_img.jpg) + +``` + +sequenceDiagram + participant NRT_RIC as Near-RT RIC + participant E2_Node as E2 Node + NRT_RIC->>E2_Node: RIC CONTROL REQUEST + E2_Node-->>NRT_RIC: RIC CONTROL ACKNOWLEDGE + +``` + +Sequence diagram showing the RIC Control procedure, successful operation. The diagram illustrates the interaction between a Near-RT RIC and an E2 Node. The Near-RT RIC sends a RIC CONTROL REQUEST message to the E2 Node. The E2 Node responds with a RIC CONTROL ACKNOWLEDGE message. The diagram shows two instances of each entity, with the top instance representing the initial state and the bottom instance representing the state after the procedure. + +**Figure 8.2.4.2-1: RIC Control procedure, successful operation** + +The Near-RT RIC initiates the procedure by sending a RIC CONTROL REQUEST message containing a unique *RIC Request ID* IE, assigned by the Near-RT RIC. + +When the Near-RT RIC sends the RIC CONTROL REQUEST message and the optional *RIC Control Ack Request* IE has been set to "Ack", or is not present, the Near-RT RIC, it shall start the timer $T_{RICcontrol}$ . + +At reception of the RIC CONTROL REQUEST message the E2 Node shall: + +- Determine the target RAN Function using the information in the *RAN Function ID* IE and initiate the requested RIC Control procedure action using information in the *RIC Control Message* IE. +- If the *RIC Call Process ID* IE is included in the RIC CONTROL REQUEST message, the E2 Node shall use this IE to identify a specific call process that was indicated in the RIC INDICATION message. +- If the RIC CONTROL REQUEST message contains the optional *RIC Control Ack Request* IE set to "Ack", or if the optional *RIC Control Ack Request* IE is not present, and the E2 Node has successfully processed the requested RIC Control procedure action, then the E2 Node shall respond with the RIC CONTROL ACKNOWLEDGE message. +- If the RIC CONTROL REQUEST message contains the optional *RIC Control Ack Request* IE set to "NoAck" and the E2 Node has successfully processed the requested RIC Control procedure action, then the E2 Node shall not send the RIC CONTROL ACKNOWLEDGE message. + +Upon reception of the RIC CONTROL ACKNOWLEDGE message, the Near-RT RIC shall stop timer $T_{RICcontrol}$ and terminate the RIC Control procedure. + +The Near-RT RIC may use the information contained in the optional *RIC Control Outcome* IE to determine subsequent actions. + +#### 8.2.4.3 Unsuccessful operation + +![Sequence diagram showing the RIC Control procedure, unsuccessful operation. A Near-RT RIC sends a RIC CONTROL REQUEST to an E2 Node. The E2 Node responds with a RIC CONTROL FAILURE message back to the Near-RT RIC.](205052185cb5539c5fd3a9ea1f2aab08_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Near-RT RIC->>E2 Node: RIC CONTROL REQUEST + E2 Node->>Near-RT RIC: RIC CONTROL FAILURE + +``` + +Sequence diagram showing the RIC Control procedure, unsuccessful operation. A Near-RT RIC sends a RIC CONTROL REQUEST to an E2 Node. The E2 Node responds with a RIC CONTROL FAILURE message back to the Near-RT RIC. + +**Figure 8.2.4.3-1: RIC Control procedure, unsuccessful operation** + +If the RIC CONTROL REQUEST message contains an invalid *RIC Call Process ID* IE, then the E2 Node shall respond with the RIC CONTROL FAILURE message with an appropriate cause value. + +If the RIC CONTROL REQUEST message contains the optional *RIC Call Process ID* IE for which the associated *RIC Time to Wait* timer had expired, then the E2 Node shall respond with the RIC CONTROL FAILURE message with an appropriate cause value. + +If the E2 Node fails to execute the requested RIC Control procedure E2SM specific action, then the E2 Node shall respond with the RIC CONTROL FAILURE message with an appropriate cause value. + +If the E2 Node detects an encoding or functional error in the E2SM specific IEs contained in the RIC CONTROL REQUEST message, then the E2 Node shall respond with the RIC CONTROL FAILURE message with an appropriate cause value. + +If the E2 Node receives a RIC CONTROL REQUEST message which contains an unknown *RAN Function ID* IE the E2 Node shall respond with the RIC CONTROL FAILURE message containing an appropriate cause value. + +If the E2 Node does not support the specific RIC Control procedure action, then the E2 Node shall respond with the RIC CONTROL FAILURE message containing an appropriate cause value. + +Upon reception of the RIC CONTROL FAILURE message the Near-RT RIC shall stop timer $T_{RICcontrol}$ , if running, and terminate the RIC Control procedure. + +The Near-RT RIC may use the information contained in the *Cause* IE and optional *RIC Control Outcome* IE to determine subsequent actions. + +#### 8.2.4.4 Abnormal conditions + +Upon reception of the ERROR INDICATION message including the *RIC Request ID* IE associated to the RIC CONTROL REQUEST message, the Near-RT RIC shall stop timer $T_{RICcontrol}$ , if running, and terminate the RIC Control procedure. + +If timer $T_{RICcontrol}$ was set when sending the RIC CONTROL REQUEST message and there was no response from the E2 node before the timer expiry, the Near-RT RIC shall send an ERROR INDICATION with the appropriate value for the *Cause* IE. + +### 8.2.5 RIC Subscription Modification procedure + +#### 8.2.5.1 General + +The purpose of the RIC Subscription Modification procedure is to modify an existing RIC subscription on an E2 node, in terms of its event trigger definition and/or the sequence of actions. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses RIC Service signalling. + +#### 8.2.5.2 Successful operation + +![Sequence diagram showing the RIC Subscription Modification procedure. A Near-RT RIC sends a RIC SUBSCRIPTION MODIFICATION REQUEST to an E2 Node. The E2 Node responds with a RIC SUBSCRIPTION MODIFICATION RESPONSE.](0c6499c0eff2c7167c61e7089eb6468d_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Note over Near-RT RIC, E2 Node: RIC SUBSCRIPTION MODIFICATION REQUEST + Note over E2 Node, Near-RT RIC: RIC SUBSCRIPTION MODIFICATION RESPONSE + +``` + +Sequence diagram showing the RIC Subscription Modification procedure. A Near-RT RIC sends a RIC SUBSCRIPTION MODIFICATION REQUEST to an E2 Node. The E2 Node responds with a RIC SUBSCRIPTION MODIFICATION RESPONSE. + +**Figure 8.2.5.2-1: RIC Subscription Modification procedure, successful operation** + +The Near-RT RIC initiates this procedure by sending the RIC SUBSCRIPTION MODIFICATION REQUEST message to the E2 node, containing the *RIC Request ID* IE to uniquely identify the existing RIC Subscription in the E2 node. + +When the Near-RT RIC sends the RIC SUBSCRIPTION MODIFICATION REQUEST message, it shall start timer $T_{\text{RICEVENTmodify}}$ . + +Upon reception of the RIC SUBSCRIPTION MODIFICATION REQUEST message, the E2 node shall determine the existing RIC Subscription and the target RAN Function from the *RIC Request ID* IE and the *RAN Function ID* IE, respectively. + +If the *RIC Event Trigger Definition to be Modified* IE is included, then the E2 node shall validate and modify the event trigger defined for the existing RIC subscription based on the contents of the IE. + +If the *RIC Actions to be Removed List* IE is included, then for every *RIC Action ID* IE included in the list, the E2 node shall delete the requested action and release the corresponding necessary resources. + +If the *RIC Actions to be Modified List* IE is included, then for every *RIC Action ID* IE included in the list for which there exists a corresponding *RIC Action Definition* IE and/or *RIC Subsequent Action* IE, the E2 node shall modify the existing behaviour for the action with the requested modification in the respective IEs and modify the corresponding necessary resources. + +If the *RIC Actions to be Modified List* IE is included, then for every *RIC Action ID* IE included in the list for which there exists a *RIC Action Execution Order* IE, the E2 node shall replace the current execution order for the action in the sequence of actions with the new execution order for the action in the sequence, as given in the *RIC Action Execution Order* IE. + +If the *RIC Actions to be Added List* IE is included, then the E2 node shall validate and add the requested actions to the existing sequence of RIC Actions in order of the *RIC Action Execution Order* IE and reserve the necessary resources for the new actions. + +The E2 node shall send the RIC SUBSCRIPTION MODIFICATION RESPONSE message back to the Near-RT RIC when one of the following cases is successfully executed: + +- If the *RIC Event Trigger Definition to be Modified* IE is present in the RIC SUBSCRIPTION MODIFICATION REQUEST message and if the requested modification for the event trigger definition was successfully performed by the E2 node, or +- If the *RIC Event Trigger Definition to be Modified* IE is not present (i.e., no modification to the event trigger definition was requested) in the RIC SUBSCRIPTION MODIFICATION REQUEST message and if at least one of the requested actions to be added or modified or removed as requested by the Near-RT RIC in *RIC Actions To Be* + +*Added List IE* or *RIC Actions to be Modified List IE* or *RIC Actions to be Removed List IE*, respectively, in the RIC SUBSCRIPTION MODIFICATION REQUEST message, was successfully performed by the E2 node. + +The E2 node shall report the result of all the requested modifications to the sequence of actions, if any, back to the Near-RT RIC in the RIC SUBSCRIPTION MODIFICATION RESPONSE message as follows: + +- A list of actions requested to be removed, indexed by the *RIC Action ID IE*, which are successfully removed by the E2 node, shall be included in the *RIC Actions Removed List IE*. +- A list of actions requested to be removed, indexed by the *RIC Action ID IE*, which failed to get removed from the sequence by the E2 node, shall be included in the *RIC Actions Failed to be Removed List IE*, with appropriate cause values. +- A list of actions requested to be modified, indexed by the *RIC Action ID IE*, which are successfully modified by the E2 node, shall be included in the *RIC Actions Modified List IE*. +- A list of actions requested to be modified, indexed by the *RIC Action ID IE*, which failed to get modified by the E2 node, shall be included in the *RIC Actions Failed to be Modified List IE* with appropriate cause values. +- A list of actions requested to be added, indexed by the *RIC Action ID IE*, which are successfully added by the E2 node, shall be included in the *RIC Actions Added List IE*. +- A list of actions requested to be added, indexed by the *RIC Action ID IE*, which failed to get added to the sequence by the E2 node, shall be included in the *RIC Actions Failed to be Added List IE* with appropriate cause values. + +If, for a given *RIC Action ID IE* in the *RIC Actions to be Modified List IE*, more than one modification to the RIC Service Action is requested in the form of *RIC Action Definition IE* and/or *RIC Action Execution Order IE* and/or *RIC Subsequent Action IE*, then the E2 node shall report that the requested action modification is successfully performed and shall include the action in the *RIC Actions Modified List IE*, if and only if, all the requested modifications to the action are successfully performed by the E2 node. + +If one of the requested modifications to the RIC Service Action is not successfully performed by the E2 node, then the E2 node shall include the RIC Service Action in the *RIC Actions Failed to be Modified List IE*, along with an appropriate cause, to indicate failure for the requested modification to the RIC Service Action. + +If, for a given *RIC Action ID IE* in the *RIC Actions to be Added IE*, either the action type in the *RIC Action Type IE* or the action definition in the *RIC Action Definition IE* or the action execution order in the *RIC Action Execution Order IE* or the subsequent action, if included, in the *RIC Subsequent Action IE* is not successfully processed by the E2 node, then the E2 node shall include the action in the *RIC Actions Failed to be Added List IE* with an appropriate cause, indicating failure to add the requested action to the existing sequence of actions. + +If, after processing the RIC Subscription Modification procedure, more than one RIC Service Action remains accepted by the E2 Node then, at each occurrence of the common Event Trigger, the sequence of RIC Service Actions shall be executed according to the considerations defined in clause 8.2.1.2. + +Upon reception of the RIC SUBSCRIPTION MODIFICATION RESPONSE message, the Near-RT RIC shall stop timer $T_{\text{RICEVENTmodify}}$ and terminate the RIC Subscription Modification procedure. + +#### 8.2.5.3 Unsuccessful operation + +![Sequence diagram showing the unsuccessful RIC Subscription Modification procedure. A Near-RT RIC sends a RIC SUBSCRIPTION MODIFICATION REQUEST to an E2 Node. The E2 Node responds with a RIC SUBSCRIPTION MODIFICATION FAILURE message back to the Near-RT RIC.](3750156e1187696fb7e00a60e2a18323_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E2 as E2 Node + participant N2 as Near-RT RIC + participant E2_2 as E2 Node + + N1-->>E2: RIC SUBSCRIPTION MODIFICATION REQUEST + E2-->>N2: RIC SUBSCRIPTION MODIFICATION FAILURE + +``` + +Sequence diagram showing the unsuccessful RIC Subscription Modification procedure. A Near-RT RIC sends a RIC SUBSCRIPTION MODIFICATION REQUEST to an E2 Node. The E2 Node responds with a RIC SUBSCRIPTION MODIFICATION FAILURE message back to the Near-RT RIC. + +**Figure 8.2.5.3-1: RIC Subscription Modification procedure, unsuccessful operation** + +If a failure occurs during the RIC Subscription Modification procedure, the E2 node shall send a RIC SUBSCRIPTION MODIFICATION FAILURE message to the Near-RT RIC with an appropriate cause value. + +If the *RIC Event Trigger Definition to be Modified* IE is present in the RIC SUBSCRIPTION MODIFICATION REQUEST message and if the requested modification for the event trigger definition is not accepted by the E2 node, the E2 node shall send a RIC SUBSCRIPTION MODIFICATION FAILURE message to the Near-RT RIC with an appropriate cause value. + +If the *RIC Event Trigger Definition to be Modified* IE is not present (i.e., no modification to the event trigger definition was requested) and if none of the requested modifications to the sequence of actions were successfully performed, that is if all of the following apply, the E2 node shall send a RIC SUBSCRIPTION MODIFICATION FAILURE message to the Near-RT RIC with an appropriate cause value: + +- *RIC Actions to be Added List* IE was present in the RIC SUBSCRIPTION MODIFICATION REQUEST message and if none of the requested additions were successfully performed +- *RIC Actions to be Modified List* IE was present in the RIC SUBSCRIPTION MODIFICATION REQUEST message and if none of the requested modifications were successfully performed +- *RIC Actions to be Removed List* IE was present in the RIC SUBSCRIPTION MODIFICATION REQUEST message and if none of the requested removals were successfully performed + +If the E2 node detects an issue with the resulting sequence of actions after processing the *RIC Actions to be Added List* IE and/or *RIC Actions to be Modified List* IE and/or *RIC Actions to be Removed List* IE, the E2 node shall send a RIC SUBSCRIPTION MODIFICATION FAILURE message to the Near-RT RIC with an appropriate cause value. + +If all RIC Service Actions in the existing RIC Subscription are proposed for removal, the E2 node shall send a RIC SUBSCRIPTION MODIFICATION FAILURE message to the Near-RT RIC with an appropriate cause value. + +Upon reception of the RIC SUBSCRIPTION FAILURE message, the Near-RT RIC shall stop the timer $T_{RICEVENTmodify}$ and terminate the RIC Subscription Modification procedure. + +#### 8.2.5.4 Abnormal conditions + +If the E2 node receives a RIC SUBSCRIPTION MODIFICATION REQUEST message including an unknown *RAN Function ID* IE, the E2 node shall send the RIC SUBSCRIPTION MODIFICATION FAILURE message to the Near-RT RIC with an appropriate cause value. + +If the E2 node receives a RIC SUBSCRIPTION MODIFICATION REQUEST message including an unknown *RIC Request ID* IE, the E2 node shall send the RIC SUBSCRIPTION MODIFICATION FAILURE message to the Near-RT RIC with an appropriate cause value. + +If the E2 node receives a RIC SUBSCRIPTION MODIFICATION REQUEST message containing the same *RIC Action ID* IE value across the *RIC Actions to be Added List* IE, *RIC Actions to be Modified List* IE and/or *RIC Actions to be Removed List* IE, then the E2 node shall send the RIC SUBSCRIPTION MODIFICATION FAILURE message to the Near-RT RIC with an appropriate cause value. + +### 8.2.6 RIC Subscription Modification Required procedure + +#### 8.2.6.1 General + +This procedure is used by the E2 Node to request the Near-RT RIC for modifying an existing RIC Subscription in the E2 Node. + +This procedure shall be initiated by the E2 Node. + +This procedure uses RIC Service signalling. + +#### 8.2.6.2 Successful operation + +![Sequence diagram showing the successful operation of the RIC Subscription Modification Required procedure. The diagram involves two entities: Near-RT RIC and E2 Node. The E2 Node sends a 'RIC SUBSCRIPTION MODIFICATION REQUIRED' message to the Near-RT RIC. The Near-RT RIC responds with a 'RIC SUBSCRIPTION MODIFICATION CONFIRM' message back to the E2 Node.](405c9cf2532981047451ccb349609c9d_img.jpg) + +``` + +sequenceDiagram + participant E2 as E2 Node + participant Near-RT as Near-RT RIC + E2->>Near-RT: RIC SUBSCRIPTION MODIFICATION REQUIRED + Near-RT-->>E2: RIC SUBSCRIPTION MODIFICATION CONFIRM + +``` + +Sequence diagram showing the successful operation of the RIC Subscription Modification Required procedure. The diagram involves two entities: Near-RT RIC and E2 Node. The E2 Node sends a 'RIC SUBSCRIPTION MODIFICATION REQUIRED' message to the Near-RT RIC. The Near-RT RIC responds with a 'RIC SUBSCRIPTION MODIFICATION CONFIRM' message back to the E2 Node. + +**Figure 8.2.6.2-1: RIC Subscription Modification Required procedure, successful operation** + +The E2 Node initiates the procedure by sending the RIC SUBSCRIPTION MODIFICATION REQUIRED message, containing *RIC Request ID* IE that was previously assigned by the Near-RT RIC during a successful RIC Subscription procedure, to the Near-RT RIC. + +Upon reception of the RIC SUBSCRIPTION MODIFICATION REQUIRED message, the Near-RT RIC shall determine the RIC Subscription from the *RIC Request ID* IE and the target RAN Function from the *RAN Function ID* IE. + +If at least one of the requested actions in *RIC Actions Required to be Modified List* IE or *RIC Actions Required to be Removed List* IE is successfully confirmed by the Near-RT RIC, then the Near-RT RIC shall perform the required procedures to update the RIC Subscription and shall send the RIC SUBSCRIPTION MODIFICATION CONFIRM message to the E2 node. + +The Near-RT RIC shall report the result to the E2 node in the RIC SUBSCRIPTION MODIFICATION CONFIRM as follows: + +- A list of actions requested to be modified, indexed by the *RIC Action ID* IE, which are successfully confirmed for modification by the Near-RT RIC, shall be included in the *RIC Actions Confirmed for Modification List* IE. +- A list of actions requested to be modified, indexed by the *RIC Action ID* IE, which are refused to be modified by the Near-RT RIC, shall be included in the *RIC Actions Refused to be Modified List* IE with appropriate cause values. +- A list of actions requested to be removed, indexed by the *RIC Action ID* IE, which are successfully confirmed for removal by the Near-RT RIC, shall be included in the *RIC Actions Confirmed for Removal List* IE. +- A list of actions requested to be removed, indexed by the *RIC Action ID* IE, which are refused to be removed by the Near-RT RIC, shall be included in the *RIC Actions Refused for Removal List* IE with appropriate cause values. + +If, after processing the RIC Subscription Modification Required procedure, more than one RIC Service Action remains in effect at the E2 node, then at each occurrence of the common Event Trigger, the sequence of RIC Service Actions shall be executed according to the considerations defined in clause 8.2.1.2. + +Upon reception of the RIC SUBSCRIPTION MODIFICATION CONFIRM message, the E2 Node shall release the necessary resources for the actions that are confirmed for removal in the *RIC Actions Confirmed for Removal List* IE, if present, and shall modify the necessary resources for the actions that are confirmed for modification in the *RIC Actions Confirmed for Modification List* IE, if present. + +#### 8.2.6.3 Unsuccessful operation + +![Sequence diagram showing the unsuccessful operation of the RIC Subscription Modification Required procedure. The diagram involves two pairs of entities: Near-RT RIC and E2 Node. The top pair shows the Near-RT RIC sending a 'RIC SUBSCRIPTION MODIFICATION REQUIRED' message to the E2 Node. The bottom pair shows the E2 Node sending a 'RIC SUBSCRIPTION MODIFICATION REFUSE' message back to the Near-RT RIC. Dashed lines connect the entities in each pair, and solid arrows indicate the direction of the messages.](20a2acad7d24c617437672ec064d43f5_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + N1-->>E1: RIC SUBSCRIPTION MODIFICATION REQUIRED + E2-->>N2: RIC SUBSCRIPTION MODIFICATION REFUSE + +``` + +Sequence diagram showing the unsuccessful operation of the RIC Subscription Modification Required procedure. The diagram involves two pairs of entities: Near-RT RIC and E2 Node. The top pair shows the Near-RT RIC sending a 'RIC SUBSCRIPTION MODIFICATION REQUIRED' message to the E2 Node. The bottom pair shows the E2 Node sending a 'RIC SUBSCRIPTION MODIFICATION REFUSE' message back to the Near-RT RIC. Dashed lines connect the entities in each pair, and solid arrows indicate the direction of the messages. + +**Figure 8.2.6.3-1: RIC Subscription Modification Required procedure, unsuccessful operation** + +If a failure occurs during the RIC Subscription Modification Required procedure the Near-RT RIC shall send the RIC SUBSCRIPTION MODIFICATION REFUSE message to the E2 node. If none of the requested modifications to the actions in the RIC SUBSCRIPTION MODIFICATION REQUIRED message (i.e., in the *RIC Actions Required to be Modified List* IE and the *RIC Actions Required to be Removed List* IE, if present) is successfully confirmed, the Near-RT RIC shall send the RIC SUBSCRIPTION MODIFICATION REFUSE message to the E2 node with an appropriate cause. + +If the Near-RT RIC detects an issue with the requested sequence of actions after processing the requested *RIC Actions Required to be Modified List* IE and/or the *RIC Actions Required to be Removed List* IE respectively, if present, the Near-RT RIC shall send the RIC SUBSCRIPTION MODIFICATION REFUSE message to the E2 node with an appropriate cause. + +If all RIC Service Action in the existing RIC Subscription are proposed for removal, the Near-RT RIC shall send a RIC SUBSCRIPTION MODIFICATION REFUSE message to the E2 Node with an appropriate cause value. + +#### 8.2.6.4 Abnormal conditions + +If the Near-RT RIC receives a RIC SUBSCRIPTION MODIFICATION REQUIRED message which contains an unknown *RAN Function ID* IE, the Near-RT RIC shall send the RIC SUBSCRIPTION MODIFICATION REFUSE message to the E2 Node with an appropriate cause value. + +If the Near-RT RIC receives a RIC SUBSCRIPTION MODIFICATION REQUIRED message containing an unknown *RIC Request ID* IE, the Near-RT RIC shall send the RIC SUBSCRIPTION MODIFICATION REFUSE message to the E2 Node with an appropriate cause value. + +### 8.2.7 RIC Query procedure + +#### 8.2.7.1 General + +This procedure is initiated by Near-RT RIC to request RAN and/or UE related information from E2 Node. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses RIC Service signalling. + +#### 8.2.7.2 Successful operation + +![Sequence diagram for successful RIC Query procedure. It shows two instances of Near-RT RIC and two instances of E2 Node. A dashed line connects the top Near-RT RIC to the top E2 Node. Another dashed line connects the bottom Near-RT RIC to the bottom E2 Node. A solid arrow labeled 'RIC QUERY REQUEST' points from the top Near-RT RIC to the top E2 Node. A solid arrow labeled 'RIC QUERY RESPONSE' points from the top E2 Node to the top Near-RT RIC.](a854945d8dbedca382e6c2c6921e3b22_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Near-RT RIC->>E2 Node: RIC QUERY REQUEST + E2 Node->>Near-RT RIC: RIC QUERY RESPONSE + +``` + +Sequence diagram for successful RIC Query procedure. It shows two instances of Near-RT RIC and two instances of E2 Node. A dashed line connects the top Near-RT RIC to the top E2 Node. Another dashed line connects the bottom Near-RT RIC to the bottom E2 Node. A solid arrow labeled 'RIC QUERY REQUEST' points from the top Near-RT RIC to the top E2 Node. A solid arrow labeled 'RIC QUERY RESPONSE' points from the top E2 Node to the top Near-RT RIC. + +**Figure 8.2.7.2-1: RIC Query procedure, successful operation** + +The Near-RT RIC initiates the procedure by sending the RIC QUERY REQUEST message, which shall contain a unique *RIC Request ID* IE, assigned by the Near-RT RIC, to the E2 Node. When the Near-RT RIC sends the RIC QUERY REQUEST message, it shall start timer T<sub>RICquery</sub>. + +At reception of the RIC QUERY REQUEST message the E2 Node shall: + +- Determine the target RAN Function using the information in the *RAN Function ID* IE. +- Validate the *RIC Query Header* IE and *RIC Query Definition* IE and if the requested information is available at E2 Node, then E2 Node shall respond back with RIC QUERY RESPONSE message containing the requested information. + +Upon reception of the RIC QUERY RESPONSE message the Near-RT RIC shall stop timer T<sub>RICquery</sub> and terminate the RIC Query procedure. + +#### 8.2.7.3 Unsuccessful operation + +![Sequence diagram for unsuccessful RIC Query procedure. It shows two instances of Near-RT RIC and two instances of E2 Node. A dashed line connects the top Near-RT RIC to the top E2 Node. Another dashed line connects the bottom Near-RT RIC to the bottom E2 Node. A solid arrow labeled 'RIC QUERY REQUEST' points from the top Near-RT RIC to the top E2 Node. A solid arrow labeled 'RIC QUERY FAILURE' points from the top E2 Node to the top Near-RT RIC.](95086bec2ff733af5890459fb8fda60f_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Near-RT RIC->>E2 Node: RIC QUERY REQUEST + E2 Node->>Near-RT RIC: RIC QUERY FAILURE + +``` + +Sequence diagram for unsuccessful RIC Query procedure. It shows two instances of Near-RT RIC and two instances of E2 Node. A dashed line connects the top Near-RT RIC to the top E2 Node. Another dashed line connects the bottom Near-RT RIC to the bottom E2 Node. A solid arrow labeled 'RIC QUERY REQUEST' points from the top Near-RT RIC to the top E2 Node. A solid arrow labeled 'RIC QUERY FAILURE' points from the top E2 Node to the top Near-RT RIC. + +**Figure 8.2.7.3-1: RIC Query procedure, unsuccessful operation** + +If the *RAN Function ID* IE in the RIC QUERY REQUEST message is not supported by E2 Node, then the E2 Node shall respond with the RIC QUERY FAILURE message to Near-RT RIC with an appropriate cause value. + +If none of the requested information in the *RIC Query Definition* IE is available at E2 Node, then E2 Node shall respond with the RIC QUERY FAILURE message to Near-RT RIC with an appropriate cause value. + +Upon reception of the RIC QUERY FAILURE message the Near-RT RIC shall stop timer $T_{RICquery}$ and terminate the RIC Query Procedure. + +#### 8.2.7.4 Abnormal conditions + +Upon reception of the ERROR INDICATION message including the *RIC Request ID* IE corresponding to the previous RIC QUERY REQUEST message, the Near-RT RIC shall stop timer $T_{RICquery}$ , if running, and terminate the RIC Query procedure. + +### 8.2.8 RIC Service Load Status procedure + +#### 8.2.8.1 General + +This procedure is used to control the reporting of RIC Service Load information for one or more RIC Services. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses RIC Service signalling. + +#### 8.2.8.2 Successful operation + +![Sequence diagram showing the RIC Load Status procedure, successful operation. The diagram shows two instances of 'Near-RT RIC' and two instances of 'E2 Node'. A message 'RIC SERVICE LOAD STATUS REQUEST' is sent from the top 'Near-RT RIC' to the top 'E2 Node'. A message 'RIC SERVICE LOAD STATUS RESPONSE' is sent from the top 'E2 Node' to the bottom 'Near-RT RIC'.](9c2e42280fbe5b6298efb323592e09f8_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + N1->>E1: RIC SERVICE LOAD STATUS REQUEST + E1-->>N2: RIC SERVICE LOAD STATUS RESPONSE + +``` + +Sequence diagram showing the RIC Load Status procedure, successful operation. The diagram shows two instances of 'Near-RT RIC' and two instances of 'E2 Node'. A message 'RIC SERVICE LOAD STATUS REQUEST' is sent from the top 'Near-RT RIC' to the top 'E2 Node'. A message 'RIC SERVICE LOAD STATUS RESPONSE' is sent from the top 'E2 Node' to the bottom 'Near-RT RIC'. + +**Figure 8.2.8.2-1: RIC Load Status procedure, successful operation** + +The Near-RT RIC initiates the procedure by sending a RIC LOAD STATUS REQUEST message to the E2 Node. + +Upon reception of the RIC SERVICE LOAD STATUS REQUEST message the E2 Node shall process the message according to the following considerations: + +The E2 Node: + +- Shall initiate the requested load information reporting according to the parameters given in the request in case the *Registration Request* IE set to "start"; or +- Shall stop all measurements and terminate the reporting in case the *Registration Request* IE is set to "stop"; or +- Shall add load measurements indicated in the request to the measurements initiated before for the given measurement IDs, in case the *Registration Request* IE is set to "add". If measurements are already initiated for a requested load measurement, this information shall be ignored. + +For each RAN Function in the *RAN Function Load Request List* IE: + +- If the *RAN Function Load Request* IE is present, the E2 Node shall collect overall load information for the RAN Function identified by the corresponding *RAN Function ID* IE. +- If the *RIC Service Load Request* IE is present in the RIC SERVICE LOAD STATUS REQUEST message, the E2 Node shall collect load information for requested RIC Services. +- If the *RIC Subscription Load Request List* IE is present and the *RIC Subscription Load Request* IE is also included, the E2 Node shall collect load information for the RIC Subscription identified by the *RIC Request ID* IE. If the *RIC Action Load Request List* IE is also present for a given RIC Subscription, the E2 Node shall collect load information only for each RIC Action identified by the corresponding *RIC Action ID* IE in the list. If the *RIC Action Load Request List* IE is not present for a given RIC Subscription, the E2 Node shall collect load information for all the RIC Actions associated with the RIC Subscription + +After processing the RIC SERVICE LOAD STATUS REQUEST message, if the E2 Node has accepted at least one item in the *RAN Function Load Request List* IE and/or *RIC Service Load Request List* IE and/or at least one item in the *RIC Subscription Load Request List* IE, the E2 Node shall send the RIC SERVICE LOAD STATUS RESPONSE message to the Near-RT RIC, and initiate load reporting using the RIC Service Load Update procedure. + +#### 8.2.8.3 Unsuccessful operation + +![Sequence diagram showing the unsuccessful operation of the RIC Service Load Status procedure. A Near-RT RIC sends a RIC SERVICE LOAD STATUS REQUEST to an E2 Node. The E2 Node responds with a RIC SERVICE LOAD STATUS FAILURE message.](9fb113f9b7e9fde28065d4eccec01ee0_img.jpg) + +``` + +sequenceDiagram + participant NRT_RIC as Near-RT RIC + participant E2_Node as E2 Node + NRT_RIC->>E2_Node: RIC SERVICE LOAD STATUS REQUEST + E2_Node-->>NRT_RIC: RIC SERVICE LOAD STATUS FAILURE + +``` + +Sequence diagram showing the unsuccessful operation of the RIC Service Load Status procedure. A Near-RT RIC sends a RIC SERVICE LOAD STATUS REQUEST to an E2 Node. The E2 Node responds with a RIC SERVICE LOAD STATUS FAILURE message. + +**Figure 8.2.8.3-1: RIC Service Load Status procedure, unsuccessful operation** + +If the E2 Node cannot accept the RIC SERVICE LOAD STATUS REQUEST message, it shall respond with the RIC SERVICE LOAD STATUS FAILURE message with an appropriate cause value. + +#### 8.3.8.4 Abnormal conditions + +Void. + +### 8.2.9 RIC Service Load Update procedure + +#### 8.3.9.1 General + +The purpose of the RIC Service Load Update procedure is to inform the Near-RT RIC of the load status in the E2 Node for one or more RIC Services. + +This procedure shall be initiated by the E2 Node. + +This procedure uses RIC Service signalling. + +#### 8.3.9.2 Successful operation + +![Diagram illustrating the RIC Service Load Update procedure, successful operation. It shows two rows of boxes. The top row contains 'Near-RT RIC' and 'E2 Node'. The bottom row contains 'Near-RT RIC' and 'E2 Node'. A red arrow points from the 'E2 Node' box in the top row to the 'Near-RT RIC' box in the bottom row, labeled 'RIC SERVICE LOAD UPDATE'.](6804f60a59e994b5203b1723a155291e_img.jpg) + +Diagram illustrating the RIC Service Load Update procedure, successful operation. It shows two rows of boxes. The top row contains 'Near-RT RIC' and 'E2 Node'. The bottom row contains 'Near-RT RIC' and 'E2 Node'. A red arrow points from the 'E2 Node' box in the top row to the 'Near-RT RIC' box in the bottom row, labeled 'RIC SERVICE LOAD UPDATE'. + +**Figure 8.2.9.2-1: RIC Service Load Update procedure, successful operation** + +The E2 Node initiates the procedure by sending a RIC LOAD UPDATE message. + +- If the *RAN Function Load Information* IE is included in the *RAN Function Load List* IE, the Near-RT RIC shall consider that the load information in the *RAN Function Load Information* IE is for the overall RAN Function load information associated with the corresponding *RAN Function ID* IE. +- If the *RIC Service Load Information* IE is included in the *RAN Function Load List* IE, the Near-RT RIC shall consider that the load information in the *RIC Service Load Information* IE is for the overall RIC Service load information associated with the corresponding *RIC Service type*. +- If the *RIC Subscription Load List* IE is included, and the *RIC Subscription Load Information* IE is also included in the *RIC Subscription Load List* IE, the Near-RT RIC shall consider that the load information in the *RIC Subscription Load Information* IE is for the overall RIC Subscription load information associated with the corresponding *RIC Request ID* IE that was previously assigned by the Near-RT RIC during a successful RIC Subscription procedure. If the *RIC Action Load List* IE is also included in the *RIC Subscription Load List* IE, the Near-RT RIC shall consider that the load information in the *RIC Action Load Information* IE is for the overall RIC Action load information associated with the corresponding *RIC Action ID* IE. + +#### 8.3.9.3 Unsuccessful operation + +Void. + +#### 8.3.9.4 Abnormal conditions + +Void. + +### 8.2.10 RIC Subscription State Control procedure + +#### 8.2.10.1 General + +This procedure is used to suspend and/or resume existing RIC Subscriptions. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses RIC Service signalling. + +#### 8.2.10.2 Successful operation + +![Sequence diagram showing the RIC Subscription State Control procedure. A Near-RT RIC sends a RIC SUBSCRIPTION STATE CONTROL REQUEST to an E2 Node. The E2 Node responds with a RIC SUBSCRIPTION STATE CONTROL RESPONSE.](9947609714e01df45158b956f9007442_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + N1->>E1: RIC SUBSCRIPTION STATE CONTROL REQUEST + E1-->>N2: RIC SUBSCRIPTION STATE CONTROL RESPONSE + +``` + +Sequence diagram showing the RIC Subscription State Control procedure. A Near-RT RIC sends a RIC SUBSCRIPTION STATE CONTROL REQUEST to an E2 Node. The E2 Node responds with a RIC SUBSCRIPTION STATE CONTROL RESPONSE. + +**Figure 8.2.10.2-1: RIC Subscription State Control procedure, successful operation** + +The Near-RT RIC initiates the procedure by sending a RIC SUBSCRIPTION STATE CONTROL REQUEST message to the E2 Node. + +Upon reception of the RIC SUBSCRIPTION STATE CONTROL REQUEST message the E2 Node shall process the message according to the following considerations for each RAN Function in the *RAN Function State Control List* IE: + +- If the *RIC Subscription To Be Suspended List* IE is present, the E2 Node shall suspend either the list of RIC Actions, if the corresponding *RIC Action List* IE is present, or the entire RIC Subscription. +- If the *RIC Subscription To Be Resumed List* IE is present, the E2 Node shall resume either the list of RIC Actions, if the corresponding *RIC Action List* IE is present, or the entire RIC Subscription. + +After processing the RIC SUBSCRIPTION STATE CONTROL REQUEST message, if the E2 Node has at least one item to be included in the *RIC Subscription Suspended List* IE and/or the *RIC Subscription Resumed List* IE for any RAN Function requested in the *RAN Function State Control List* IE, the E2 Node shall send the RIC SUBSCRIPTION STATE CONTROL RESPONSE message to the Near-RT RIC. + +If, after processing the RIC SUBSCRIPTION STATE CONTROL REQUEST message, one or more RIC Subscriptions have been accepted to be suspended by the E2 Node without the corresponding *RIC Action List* IE present then, the corresponding Event Trigger, defined in clause 8.2.1.2, shall be suspended. + +If, after processing the RIC SUBSCRIPTION STATE CONTROL REQUEST message, one or more RIC Subscriptions have been accepted to be resumed by the E2 Node then, the corresponding Event Trigger, defined in clause 8.2.1.2, shall be resumed and at each occurrence of the corresponding Event Trigger, the sequence of RIC Service Actions shall be executed according to the considerations defined in clause 8.2.1.2. + +#### 8.2.10.3 Unsuccessful operation + +![Sequence diagram for RIC Subscription State Control procedure, unsuccessful operation. The diagram shows two instances of Near-RT RIC and two instances of E2 Node. A message 'RIC SUBSCRIPTION STATE CONTROL REQUEST' is sent from the top Near-RT RIC to the top E2 Node. A message 'RIC SUBSCRIPTION STATE CONTROL FAILURE' is sent from the top E2 Node to the bottom Near-RT RIC.](dde8b736178d4fcdd60f812a89690fac_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant N2 as Near-RT RIC + participant E1 as E2 Node + participant E2 as E2 Node + N1->>E1: RIC SUBSCRIPTION STATE CONTROL REQUEST + E1->>N2: RIC SUBSCRIPTION STATE CONTROL FAILURE + +``` + +Sequence diagram for RIC Subscription State Control procedure, unsuccessful operation. The diagram shows two instances of Near-RT RIC and two instances of E2 Node. A message 'RIC SUBSCRIPTION STATE CONTROL REQUEST' is sent from the top Near-RT RIC to the top E2 Node. A message 'RIC SUBSCRIPTION STATE CONTROL FAILURE' is sent from the top E2 Node to the bottom Near-RT RIC. + +**Figure 8.2.10.3-1: RIC Subscription State Control procedure, unsuccessful operation** + +If the E2 Node cannot accept the RIC SUBSCRIPTION STATE CONTROL REQUEST message it shall respond with the RIC SUBSCRIPTION STATE CONTROL FAILURE message with an appropriate cause value. + +If the RIC Subscription State Control procedure failure occurs, the Near-RT RIC and E2 Node shall continue to operate with their existing configuration data. + +#### 8.2.10.4 Abnormal conditions + +Void. + +### 8.2.11 RIC Assistance procedure + +#### 8.2.11.1 General + +This procedure is used to utilize an assistance service offered by the Near-RT RIC. + +This procedure shall be initiated by the E2 Node. + +This procedure uses RIC Service signalling. + +#### 8.2.11.2 Successful operation + +![Sequence diagram for RIC Assistance procedure, successful operation. The diagram shows two instances of Near-RT RIC and two instances of E2 Node. A message 'RIC ASSISTANCE REQUEST' is sent from the top E2 Node to the top Near-RT RIC. A message 'RIC ASSISTANCE RESPONSE' is sent from the top Near-RT RIC to the bottom E2 Node.](380d95ac3779a767fbfa5330b29f28f9_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant N2 as Near-RT RIC + participant E1 as E2 Node + participant E2 as E2 Node + E1->>N1: RIC ASSISTANCE REQUEST + N1->>E2: RIC ASSISTANCE RESPONSE + +``` + +Sequence diagram for RIC Assistance procedure, successful operation. The diagram shows two instances of Near-RT RIC and two instances of E2 Node. A message 'RIC ASSISTANCE REQUEST' is sent from the top E2 Node to the top Near-RT RIC. A message 'RIC ASSISTANCE RESPONSE' is sent from the top Near-RT RIC to the bottom E2 Node. + +**Figure 8.2.11.2-1: RIC Assistance procedure, successful operation** + +The E2 Node initiates the procedure by sending a RIC ASSISTANCE REQUEST message which shall contain a unique *RIC Request ID* IE, assigned by the E2 Node, to the Near-RT RIC. When the E2 Node sends the RIC ASSISTANCE REQUEST message, it shall start timer $T_{RICassist}$ . + +At reception of the RIC ASSITANCE REQUEST message the Near-RT RIC shall: + +- Consider the *RIC Assistance Header* IE and *RIC Assistance Message* IE to determine the requested service and if available at Near-RT RIC, then Near-RT RIC shall respond back with RIC ASSISTANCE RESPONSE message for the requested service with the result contained in the *RIC Assistance Header* IE and *RIC Assistance Outcome* IE. + +Upon reception of the RIC ASSISTANCE RESPONSE message the E2 Node shall stop timer $T_{RICassist}$ and terminate the RIC Assistance procedure. + +##### Interactions with RIC Assistance Indication procedure: + +If the optional *RIC Assistance Update* IE is present, the Near-RT RIC shall use the *RIC Assistance Update Number* IE, if present, to determine the maximum number of RIC ASSISTANCE INDICATION messages to the E2 Node to provide updates for the requested assistance service offered by the Near-RT RIC. + +If the *RIC Assistance Update Number* IE is not present, then the Near-RT RIC shall continue to send RIC ASSISTANCE INDICATION messages until reception of the RIC ASSISTANCE HALT message. + +#### 8.2.11.3 Unsuccessful operation + +![Sequence diagram showing the unsuccessful RIC Assistance procedure. The diagram involves two entities: Near-RT RIC and E2 Node. The E2 Node sends a RIC ASSISTANCE REQUEST to the Near-RT RIC, and the Near-RT RIC responds with a RIC ASSISTANCE FAILURE.](083cf31f954126de4a2d9d49aba4205f_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + + E2 Node->>Near-RT RIC: RIC ASSISTANCE REQUEST + Near-RT RIC->>E2 Node: RIC ASSISTANCE FAILURE + +``` + +Sequence diagram showing the unsuccessful RIC Assistance procedure. The diagram involves two entities: Near-RT RIC and E2 Node. The E2 Node sends a RIC ASSISTANCE REQUEST to the Near-RT RIC, and the Near-RT RIC responds with a RIC ASSISTANCE FAILURE. + +**Figure 8.2.11.3-1: RIC Assistance procedure, unsuccessful operation** + +Origin + +If the Near-RT RIC cannot accept the RIC ASSISTANCE REQUEST message it shall respond with the RIC ASSISTANCE FAILURE message with an appropriate cause value. + +Upon reception of the RIC ASSISTANCE FAILURE message the E2 Node shall stop timer $T_{RICassist}$ and terminate the RIC Assistance Procedure. + +#### 8.2.11.4 Abnormal conditions + +Void. + +### 8.2.12 RIC Assistance Indication procedure + +#### 8.2.12.1 General + +This procedure is used to provide an update for an assistance service offered by the Near-RT RIC. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses RIC Service signalling. + +#### 8.2.12.2 Successful operation + +![Diagram of the RIC Assistance Indication procedure, successful operation. It shows two pairs of boxes. On the left, a 'Near-RT RIC' box is connected to another 'Near-RT RIC' box below it. On the right, an 'E2 Node' box is connected to another 'E2 Node' box below it. A horizontal arrow points from the top 'Near-RT RIC' box to the top 'E2 Node' box, labeled 'RIC ASSISTANCE INDICATION'.](2477e6c2d24a37cf2dfa950078d99cc6_img.jpg) + +``` + +graph LR + N1[Near-RT RIC] --- N2[Near-RT RIC] + E1[E2 Node] --- E2[E2 Node] + N1 -- "RIC ASSISTANCE INDICATION" --> E1 + +``` + +Diagram of the RIC Assistance Indication procedure, successful operation. It shows two pairs of boxes. On the left, a 'Near-RT RIC' box is connected to another 'Near-RT RIC' box below it. On the right, an 'E2 Node' box is connected to another 'E2 Node' box below it. A horizontal arrow points from the top 'Near-RT RIC' box to the top 'E2 Node' box, labeled 'RIC ASSISTANCE INDICATION'. + +**Figure 8.2.12.2-1: RIC Assistance Indication procedure, successful operation** + +The Near-RT RIC initiates the procedure by sending a RIC ASSISTANCE INDICATION message which shall contain a unique *RIC Request ID* IE, assigned by the E2 Node during a previous RIC Assistance procedure, to the E2 Node, and the updated assistance service result in *RIC Assistance Header* IE and *RIC Assistance Outcome* IE. Each update of the requested assistance service shall contain a unique *RIC Assistance SN* IE. + +##### Interactions with RIC Assistance Halt procedure: + +If the E2 Node sends a RIC ASSISTANCE HALT message, the Near-RT RIC shall halt sending RIC ASSISTANCE INDICATION messages corresponding to the *RIC Request ID* IE contained in the message. + +#### 8.2.12.3 Unsuccessful operation + +Not applicable. + +#### 8.2.12.4 Abnormal conditions + +Void. + +### 8.2.13 RIC Assistance Halt procedure + +#### 8.2.13.1 General + +This procedure is used to halt updates for an assistance service offered by the Near-RT RIC. + +This procedure shall be initiated by the E2 Node. + +This procedure uses RIC Service signalling. + +#### 8.2.13.2 Successful operation + +![Diagram illustrating the RIC Assistance Halt procedure, successful operation. It shows two pairs of boxes: 'Near-RT RIC' and 'E2 Node' at the top, and 'Near-RT RIC' and 'E2 Node' at the bottom. A red arrow labeled 'RIC ASSISTANCE HALT' points from the top 'E2 Node' box to the top 'Near-RT RIC' box.](bb616915edf9be8a8255f5ef2f442f4b_img.jpg) + +``` + +graph TD + subgraph Top + NRT1[Near-RT RIC] + E21[E2 Node] + end + subgraph Bottom + NRT2[Near-RT RIC] + E22[E2 Node] + end + E21 -- "RIC ASSISTANCE HALT" --> NRT1 + +``` + +Diagram illustrating the RIC Assistance Halt procedure, successful operation. It shows two pairs of boxes: 'Near-RT RIC' and 'E2 Node' at the top, and 'Near-RT RIC' and 'E2 Node' at the bottom. A red arrow labeled 'RIC ASSISTANCE HALT' points from the top 'E2 Node' box to the top 'Near-RT RIC' box. + +**Figure 8.2.13.2-1: RIC Assistance Halt procedure, successful operation** + +The E2 Node initiates the procedure by sending a RIC ASSISTANCE HALT message which shall contain a unique *RIC Request ID* IE, assigned by the E2 Node during a previous RIC Assistance procedure, to the Near-RT RIC. + +Upon reception the Near-RT RIC shall halt the requested updates to the RIC Assistance service. + +#### 8.2.13.3 Unsuccessful operation + +Not applicable. + +#### 8.3.13.4 Abnormal conditions + +If the Near-RT RIC receives a RIC Assistance Halt request from the E2 Node that does not correspond to an ongoing RIC Assistance service, then the Near-RT RIC shall ignore the message. + +## 8.3 Global procedures + +### 8.3.1 E2 Setup procedure + +#### 8.3.1.1 General + +The purpose of the E2 Setup procedure is to exchange application level data needed for the E2 Node and Near-RT RIC to correctly interoperate on the E2 interface. This procedure shall be the first E2AP procedure triggered after the TNL association has become operational. + +This procedure erases any existing application level configuration data in the two nodes and replace it by the one received. + +This procedure shall be initiated by the E2 Node. + +This procedure uses E2 Support Function signalling. + +#### 8.3.1.2 Successful operation + +![Sequence diagram for successful E2 Setup procedure. The E2 Node sends an E2 SETUP REQUEST to the Near-RT RIC, and the Near-RT RIC responds with an E2 SETUP RESPONSE.](38ba70877eb8ae3317247595766156c1_img.jpg) + +``` + +sequenceDiagram + participant E2Node as E2 Node + participant NearRT RIC as Near-RT RIC + E2Node->>NearRT RIC: E2 SETUP REQUEST + NearRT RIC-->>E2Node: E2 SETUP RESPONSE + +``` + +Sequence diagram for successful E2 Setup procedure. The E2 Node sends an E2 SETUP REQUEST to the Near-RT RIC, and the Near-RT RIC responds with an E2 SETUP RESPONSE. + +**Figure 8.3.1.2-1: E2 Setup procedure, successful operation** + +The E2 Node initiates the procedure by sending the E2 SETUP REQUEST message including the appropriate data to a Near-RT RIC. + +If the Near-RT RIC has successfully processed the *RAN Functions Added List* IE then Near-RT RIC shall contain, in the E2 SETUP RESPONSE message, the *RAN Functions Accepted List* IE and/or the *RAN Functions Rejected List* IE. + +If the Near-RT RIC has successfully processed the *E2 Node Component Configuration Addition List* IE then Near-RT RIC shall contain, in the E2 SETUP RESPONSE message, the *E2 Node Component Configuration Addition Acknowledge List* IE. + +#### 8.3.1.3 Unsuccessful operation + +![Sequence diagram for unsuccessful E2 Setup procedure. The E2 Node sends an E2 SETUP REQUEST to the Near-RT RIC, and the Near-RT RIC responds with an E2 SETUP FAILURE.](45e40350c62c2092ded75076be8626cc_img.jpg) + +``` + +sequenceDiagram + participant E2Node as E2 Node + participant NearRT RIC as Near-RT RIC + E2Node->>NearRT RIC: E2 SETUP REQUEST + NearRT RIC-->>E2Node: E2 SETUP FAILURE + +``` + +Sequence diagram for unsuccessful E2 Setup procedure. The E2 Node sends an E2 SETUP REQUEST to the Near-RT RIC, and the Near-RT RIC responds with an E2 SETUP FAILURE. + +**Figure 8.3.1.3-1: E2 Setup procedure, unsuccessful operation** + +If the Near-RT RIC cannot accept the setup it shall respond with an E2 SETUP FAILURE message with an appropriate cause value. + +The Near-RT RIC may provide an alternative *Transport Layer Information* IE in the E2 SETUP FAILURE message for the E2 Node to use when reinitiating the E2 Setup procedure towards the Near-RT RIC. + +If the E2 SETUP FAILURE message includes the *Time To Wait* IE, the E2 node shall wait at least for the indicated time before reinitiating the E2 Setup procedure towards the Near-RT RIC. + +#### 8.3.1.4 Abnormal conditions + +If the first message received for a specific TNL association is not an E2 SETUP REQUEST, E2 SETUP RESPONSE, E2 SETUP FAILURE or E2 NODE CONFIGURATION UPDATE message then this shall be treated as a logical error. + +### 8.3.2 Reset procedure + +#### 8.3.2.1 General + +The purpose of the Reset procedure is to initialize or re-initialize the E2 Node in the event of Near-RT RIC failure or vice-versa. + +This procedure does not affect the application level data exchanged during the E2 Setup procedure, E2 Node Configuration Update procedure and RIC Service Update procedure. + +This procedure shall be initiated by the E2 Node or the Near-RT RIC. + +This procedure uses E2 Support Function signalling. + +#### 8.3.2.2 Successful operation + +This procedure may be initiated by either Near-RT RIC or E2 Node. + +![Sequence diagram for Reset procedure initiated by E2 Node](25adb1779caeee8152d405858cc3057d_img.jpg) + +``` + +sequenceDiagram + participant NRT_RIC as Near-RT RIC + participant E2_Node as E2 Node + Note over NRT_RIC, E2_Node: E2 Node Initiated + E2_Node->>NRT_RIC: RESET REQUEST + NRT_RIC-->>E2_Node: RESET RESPONSE + +``` + +The diagram illustrates the Reset procedure initiated by the E2 Node. It shows two instances of the Near-RT RIC and E2 Node. A dashed line connects the top E2 Node to the top Near-RT RIC. A solid arrow labeled 'RESET REQUEST' points from the top E2 Node to the top Near-RT RIC. A solid arrow labeled 'RESET RESPONSE' points from the top Near-RT RIC to the top E2 Node. Below these, the same two entities are shown again, representing the state after the reset. + +Sequence diagram for Reset procedure initiated by E2 Node + +**Figure 8.3.2.2-1: Reset, successful operation (E2 Node Initiated)** + +![Sequence diagram for Reset procedure initiated by Near-RT RIC](b48083788f638a33d728bde1acd0560a_img.jpg) + +``` + +sequenceDiagram + participant NRT_RIC as Near-RT RIC + participant E2_Node as E2 Node + Note over NRT_RIC, E2_Node: Near-RT RIC Initiated + NRT_RIC->>E2_Node: RESET REQUEST + E2_Node-->>NRT_RIC: RESET RESPONSE + +``` + +The diagram illustrates the Reset procedure initiated by the Near-RT RIC. It shows two instances of the Near-RT RIC and E2 Node. A dashed line connects the top Near-RT RIC to the top E2 Node. A solid arrow labeled 'RESET REQUEST' points from the top Near-RT RIC to the top E2 Node. A solid arrow labeled 'RESET RESPONSE' points from the top E2 Node to the top Near-RT RIC. Below these, the same two entities are shown again, representing the state after the reset. + +Sequence diagram for Reset procedure initiated by Near-RT RIC + +**Figure 8.3.2.2-2: Reset, successful operation (Near-RT RIC Initiated)** + +When the Reset procedure is initiated, the Near-RT RIC and E2 Node shall: + +- Delete any pre-established RIC Subscriptions. +- Gracefully terminate any ongoing Near-RT RIC call processes using Insert, Control or Policy RIC Service Actions while ensuring that impact to ongoing calls for connected UE is minimized. + +After the Reset has been completed, the Near-RT RIC may re-issue any required RIC Subscriptions. + +##### Interactions with other procedures: + +If the RESET REQUEST message is received, any other ongoing procedure (except for another Reset procedure) on the same E2 interface related to ongoing RIC Services shall be aborted. + +#### 8.3.2.3 Unsuccessful operation + +Void. + +#### 8.3.2.4 Abnormal conditions + +Void. + +### 8.3.3 Error Indication + +#### 8.3.3.1 General + +The Error Indication procedure is initiated by either the E2 Node or the Near-RT RIC to report detected errors in one incoming message, provided they cannot be reported by an appropriate failure message. + +This procedure shall be initiated by the E2 Node or the Near-RT RIC. + +If the error situation arises due to reception of a message utilizing RIC Service signalling, then the Error Indication procedure uses RIC Service signalling. Otherwise, the procedure uses E2 Support Function signalling. + +#### 8.3.3.2 Successful operation + +![Diagram showing Error Indication initiated by E2 Node. The top row shows 'Near-RT RIC' and 'E2 Node'. The bottom row shows 'Near-RT RIC' and 'E2 Node'. A red arrow labeled 'ERROR INDICATION' points from the 'E2 Node' in the top row to the 'Near-RT RIC' in the bottom row.](697f8ef39284553d8d9a418ec08eea28_img.jpg) + +Diagram showing Error Indication initiated by E2 Node. The top row shows 'Near-RT RIC' and 'E2 Node'. The bottom row shows 'Near-RT RIC' and 'E2 Node'. A red arrow labeled 'ERROR INDICATION' points from the 'E2 Node' in the top row to the 'Near-RT RIC' in the bottom row. + +**Figure 8.3.3.2-1: Error Indication, (E2 Node initiated) successful operation** + +![Diagram showing Error Indication initiated by Near-RT RIC. The top row shows 'Near-RT RIC' and 'E2 Node'. The bottom row shows 'Near-RT RIC' and 'E2 Node'. A red arrow labeled 'ERROR INDICATION' points from the 'Near-RT RIC' in the top row to the 'E2 Node' in the bottom row.](37052f7c575029805b65a7f71fb4ac56_img.jpg) + +Diagram showing Error Indication initiated by Near-RT RIC. The top row shows 'Near-RT RIC' and 'E2 Node'. The bottom row shows 'Near-RT RIC' and 'E2 Node'. A red arrow labeled 'ERROR INDICATION' points from the 'Near-RT RIC' in the top row to the 'E2 Node' in the bottom row. + +**Figure 8.3.3.2-2: Error Indication, (Near-RT RIC Initiated) successful operation** + +When the conditions defined in clause 10 are fulfilled, the Error Indication procedure shall be initiated by an ERROR INDICATION message sent from the node detecting the error situation. + +The ERROR INDICATION message shall contain at least either the *Cause* IE or the *Criticality Diagnostics* IE and may include *RAN Function ID* IE and *RIC Request ID* IE. + +#### 8.3.3.3 Unsuccessful operation + +Not applicable. + +#### 8.3.3.4 Abnormal conditions + +Not applicable. + +### 8.3.4 RIC Service Update procedure + +#### 8.3.4.1 General + +The purpose of the RIC Service Update procedure is to update application level RIC Service related data needed for E2 Node and Near-RT RIC to interoperate correctly over the E2 interface. + +This procedure shall be initiated by the E2 Node. + +This procedure uses E2 Support Function signalling. + +#### 8.3.4.2 Successful operation + +![Sequence diagram showing the RIC Service Update procedure. The E2 Node sends a RIC SERVICE UPDATE message to the Near-RT RIC, and the Near-RT RIC sends a RIC SERVICE UPDATE ACKNOWLEDGE message back to the E2 Node.](5e8fd51f64c880cffc302a40c51b930b_img.jpg) + +``` + +sequenceDiagram + participant E2Node as E2 Node + participant NearRT RIC as Near-RT RIC + E2Node->>NearRT RIC: RIC SERVICE UPDATE + NearRT RIC-->>E2Node: RIC SERVICE UPDATE ACKNOWLEDGE + +``` + +Sequence diagram showing the RIC Service Update procedure. The E2 Node sends a RIC SERVICE UPDATE message to the Near-RT RIC, and the Near-RT RIC sends a RIC SERVICE UPDATE ACKNOWLEDGE message back to the E2 Node. + +**Figure 8.3.4.2-1: RIC Service Update procedure, successful operation** + +An E2 Node initiates the procedure by sending a RIC SERVICE UPDATE message to the Near-RT RIC. + +If the E2 Node has taken into operational use one or more RAN Functions supporting RIC Services, the RIC SERVICE UPDATE message shall include the *RAN Functions Added List* IE. + +If the E2 Node has modified one or more RAN Functions supporting RIC Services, the RIC SERVICE UPDATE message shall include the *RAN Functions Modified List* IE. + +If the E2 Node has removed from operational use one or more RAN Functions supporting RIC Services, the RIC SERVICE UPDATE message shall include the *RAN Functions Deleted List* IE. + +Upon reception of a RIC SERVICE UPDATE message, Near-RT RIC shall update the application level data for E2 Node as follows: + +- If the *RAN Function Added List* IE is contained in the RIC SERVICE UPDATE message, Near-RT RIC shall add each listed accepted RAN Function according to the information in the *RAN Function ID* IE and *RAN Function Definition* IE and store the corresponding *RAN Function Revision* IE. + +- If the *RAN Function Modified List* IE is contained in the RIC SERVICE UPDATE message, Near-RT RIC shall modify accepted information of supported RAN Functions according to the information in the *RAN Function Definition* IE and update the corresponding *RAN Function Revision* IE. +- If the *RAN Function Deleted List* IE is contained in the RIC SERVICE UPDATE message, Near-RT RIC shall delete information of RAN Function indicated by the *RAN Function ID* IE along with the corresponding *RAN Function Revision* IE. + +These changes may be processed in the Near-RT-RIC and may be used when issuing RIC SUBSCRIPTION REQUEST and RIC CONTROL to provide valid *RAN Function ID* IE. + +If at least one RAN Function update request present in the RIC SERVICE UPDATE message is successful, then the Near-RT RIC shall send the RIC SERVICE UPDATE ACKNOWLEDGE message to the initiating E2 Node with: + +- *RAN Functions Accepted List* IE indicating accepted requests to add, modify, and/or delete the corresponding RAN Function information. +- If required, the *RAN Functions Rejected List* IE indicating rejected requests to add, modify, and/or delete the corresponding RAN Function information. + +If the Near-RT RIC receives a RIC SERVICE UPDATE message without any IE except for *Message Type* IE, then the Near-RT RIC shall reply with RIC SERVICE UPDATE ACKNOWLEDGE message without any IE except for *Message Type* IE, and shall not perform any updates to the existing application level data. + +#### 8.3.4.3 Unsuccessful operation + +![Sequence diagram showing the RIC Service Update procedure for an unsuccessful operation. It involves two instances of Near-RT RIC and two instances of E2 Node. The top instance of Near-RT RIC sends a RIC SERVICE UPDATE message to the top instance of E2 Node. The top instance of E2 Node then sends a RIC SERVICE UPDATE FAILURE message back to the top instance of Near-RT RIC.](bba9f1de9f292798f6d2592d8466eaee_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + N1->>E1: RIC SERVICE UPDATE + E1-->>N1: RIC SERVICE UPDATE FAILURE + +``` + +Sequence diagram showing the RIC Service Update procedure for an unsuccessful operation. It involves two instances of Near-RT RIC and two instances of E2 Node. The top instance of Near-RT RIC sends a RIC SERVICE UPDATE message to the top instance of E2 Node. The top instance of E2 Node then sends a RIC SERVICE UPDATE FAILURE message back to the top instance of Near-RT RIC. + +**Figure 8.3.4.3-1: RIC Service Update procedure, unsuccessful operation** + +If the Near-RT RIC cannot accept the update it shall respond with a RIC SERVICE UPDATE FAILURE message with an appropriate cause value. + +If the RIC SERVICE UPDATE FAILURE message includes the *Time To Wait* IE, the E2 Node shall wait at least for the indicated time before reinitiating the RIC Service Update procedure towards the same Near-RT RIC. Both nodes shall continue to operate the E2 with their existing RIC Service data. + +#### 8.3.4.4 Abnormal conditions + +Void. + +### 8.3.4A RIC Service Query procedure + +#### 8.3.4A.1 General + +The purpose of the RIC Service Query procedure is to ensure alignment between Near-RT RIC and E2 Node concerning application level RIC Service related data needed for E2 Node and Near-RT RIC to interoperate correctly over the E2 interface. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses E2 Support Function signalling. + +#### 8.3.4A.2 Successful operation + +![Sequence diagram showing the RIC Service Query procedure between Near-RT RIC and E2 Node.](1ec46460065c10d2c8a46803189839aa_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + N1->>E1: RIC SERVICE QUERY + E1-->>N1: RIC Service Update procedure + +``` + +The diagram illustrates the RIC Service Query procedure. It shows two instances of the Near-RT RIC and two instances of the E2 Node. The top instance of the Near-RT RIC sends a 'RIC SERVICE QUERY' message to the top instance of the E2 Node. The top instance of the E2 Node then sends a 'RIC Service Update procedure' message back to the top instance of the Near-RT RIC. The bottom instances of both entities are shown but do not participate in the message exchange. + +Sequence diagram showing the RIC Service Query procedure between Near-RT RIC and E2 Node. + +**Figure 8.3.4A.2-1: RIC Service Query procedure, successful operation** + +The Near-RT RIC initiates the procedure by sending a RIC SERVICE QUERY message to the E2 Node. + +Upon reception of the RIC SERVICE QUERY message the E2 Node shall initiate the RIC Service Update procedure according to the following considerations: + +- If the *RAN Function Accepted List* IE is not present in the RIC SERVICE QUERY message, the E2 Node shall send the RIC SERVICE UPDATE message with the complete list of supported RAN Functions in the *RAN Function Added List* IE. +- If the *RAN Function Accepted List* IE is present in the RIC SERVICE QUERY message and aligns with the list of supported RAN Functions at the E2 Node, the E2 Node shall send the RIC SERVICE UPDATE message without the *RAN Function Added List* IE, *RAN Function Modified List* IE and *RAN Function Deleted List* IE. +- If the *RAN Function Accepted List* IE is present in the RIC SERVICE QUERY message and the list of RAN Functions in the *RAN Function Accepted List* IE does not align with the list of supported RAN Functions at the E2 node, the E2 Node shall send the RIC SERVICE UPDATE message with the *RAN Function Added List* IE, *RAN Function Modified List* IE and/or *RAN Function Deleted List* IE to ensure realignment of RAN Functions between the E2 Node and the Near-RT RIC. + +The Near-RT RIC completes the RIC Service Update procedure as described in clause 8.3.4. + +#### 8.3.4A.3 Unsuccessful operation + +Void. + +#### 8.3.4A.4 Abnormal conditions + +Void. + +### 8.3.5 E2 Node Configuration Update procedure + +#### 8.3.5.1 General + +The purpose of the E2 Node Configuration Update procedure is to update application level E2 Node configuration data needed for E2 Node and Near-RT RIC to interoperate correctly over the E2 interface and to support E2 Node initiated TNL association removal. + +This procedure shall be initiated by the E2 Node. + +This procedure uses E2 Support Function signalling. + +#### 8.3.5.2 Successful operation + +![Sequence diagram showing the E2 Node Configuration Update procedure. The E2 Node sends an 'E2 NODE CONFIGURATION UPDATE' message to the Near-RT RIC, which then responds with an 'E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE' message.](91db642834e2e448c6355358edc62e23_img.jpg) + +``` + +sequenceDiagram + participant E2Node as E2 Node + participant NearRT RIC as Near-RT RIC + E2Node->>NearRT RIC: E2 NODE CONFIGURATION UPDATE + NearRT RIC-->>E2Node: E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE + +``` + +Sequence diagram showing the E2 Node Configuration Update procedure. The E2 Node sends an 'E2 NODE CONFIGURATION UPDATE' message to the Near-RT RIC, which then responds with an 'E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE' message. + +**Figure 8.3.5.2-1: E2 Node Configuration Update procedure, successful operation** + +An E2 Node initiates the procedure by sending a E2 NODE CONFIGURATION UPDATE message to the Near-RT RIC. The message shall include an appropriate set of up-to-date E2 Node-related configuration data that the E2 Node has just taken into operational use. + +Upon reception of the E2 NODE CONFIGURATION UPDATE message, Near-RT RIC shall update the application level data for the E2 Node as follows: + +Update of E2 Node configuration information in Near-RT RIC: + +- If *E2 Node Component Configuration Addition List* IE is contained in the E2 NODE CONFIGURATION UPDATE message, Near-RT RIC shall add the E2 Node Component Configuration information accordingly. +- If *E2 Node Component Configuration Update List* IE is contained in the E2 NODE CONFIGURATION UPDATE message, Near-RT RIC shall modify the E2 Node Component Configuration information accordingly. +- If *E2 Node Component Configuration Removal List* IE is contained in the E2 NODE CONFIGURATION UPDATE message, Near-RT RIC shall remove the E2 Node Component Configuration information accordingly. + +If *Global E2 Node ID* IE is contained in the E2 NODE CONFIGURATION UPDATE message for a newly established SCTP association, the Near-RT RIC shall associate the TNL association with the related E2 Node. + +If the E2 NODE CONFIGURATION UPDATE message includes *E2 Node TNL Association To Remove List* IE, and the *Endpoint IP address* IE and the *Port Number* IE for both TNL endpoints of the TNL association(s) are included in the *E2 Node* + +*TNL Association To Remove List* IE, the Near-RT RIC shall, if supported, consider that the TNL association(s) indicated by both received TNL endpoints will be removed by the E2 Node. + +If the E2 NODE CONFIGURATION UPDATE message includes *E2 Node TNL Association To Remove List* IE, and the *Endpoint IP address* IE, or the *Endpoint IP address* IE and the *Port Number* IE for one or both of the TNL endpoints is included in the *E2 Node TNL Association To Remove List* IE in E2 NODE CONFIGURATION UPDATE message, the Near-RT RIC shall, if supported, consider that the TNL association(s) indicated by the received endpoint IP address(es) will be removed by the E2 Node. + +After successful update of requested information, Near-RT RIC shall reply with the E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message to inform the initiating E2 Node that the requested update of application level data was performed successfully. + +If the Near-RT RIC receives an E2 NODE CONFIGURATION UPDATE message without any IE except for *Message Type* IE and *Transaction ID* IE, the Near-RT RIC shall reply with the E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE message without performing any updates to the existing configuration. + +#### 8.3.5.3 Unsuccessful operation + +![Sequence diagram showing an unsuccessful E2 Node Configuration Update procedure. A Near-RT RIC sends an E2 NODE CONFIGURATION UPDATE message to an E2 Node. The E2 Node responds with an E2 NODE CONFIGURATION UPDATE FAILURE message back to the Near-RT RIC.](c6359a2dd418dc2cbdce8601a2057f01_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + + N1-->>E1: E2 NODE CONFIGURATION UPDATE + E1-->>N2: E2 NODE CONFIGURATION UPDATE FAILURE + +``` + +Sequence diagram showing an unsuccessful E2 Node Configuration Update procedure. A Near-RT RIC sends an E2 NODE CONFIGURATION UPDATE message to an E2 Node. The E2 Node responds with an E2 NODE CONFIGURATION UPDATE FAILURE message back to the Near-RT RIC. + +**Figure 8.3.5.3-1: E2 Node Configuration Update procedure, unsuccessful operation** + +If Near-RT RIC cannot accept the E2 NODE CONFIGURATION UPDATE message it shall respond with the E2 NODE CONFIGURATION UPDATE FAILURE message with an appropriate cause value. + +If the E2 NODE CONFIGURATION UPDATE FAILURE message includes the *Time To Wait* IE the E2 Node shall wait at least for the indicated time before reinitiating the E2 Node Configuration Update procedure towards the same Near-RT RIC. + +If the Near-RT RIC receives an E2 NODE CONFIGURATION UPDATE message containing an *E2 Node Component Configuration Update Item* IE for an E2 Node component that was not previously declared by an *E2 Node Component Configuration Addition Item* IE then the Near-RT RIC shall indicate to the E2 Node that the update failed with appropriate cause value. + +If the E2 Node Configuration Update procedure failure occurs, the Near-RT RIC and E2 Node shall continue to operate with their existing configuration data. + +#### 8.3.5.4 Abnormal conditions + +Void. + +### 8.3.6 E2 Connection Update procedure + +#### 8.3.6.1 General + +The purpose of the E2 Connection Update procedure is to allow the Near-RT RIC to update the TNL information associated with the E2 interface connection between the E2 Node and Near-RT RIC. + +This procedure shall be initiated by the Near-RT RIC. + +This procedure uses E2 Support Function signalling. + +#### 8.3.6.2 Successful operation + +![Sequence diagram showing the E2 Connection Update procedure. A Near-RT RIC sends an E2 CONNECTION UPDATE message to an E2 Node. The E2 Node responds with an E2 CONNECTION UPDATE ACKNOWLEDGE message.](d18081f600ec5887204f5bd91b6e156b_img.jpg) + +``` + +sequenceDiagram + participant NR1 as Near-RT RIC + participant EN1 as E2 Node + participant NR2 as Near-RT RIC + participant EN2 as E2 Node + NR1-->>EN1: E2 CONNECTION UPDATE + EN1-->>NR2: E2 CONNECTION UPDATE ACKNOWLEDGE + +``` + +Sequence diagram showing the E2 Connection Update procedure. A Near-RT RIC sends an E2 CONNECTION UPDATE message to an E2 Node. The E2 Node responds with an E2 CONNECTION UPDATE ACKNOWLEDGE message. + +**Figure 8.3.6.2-1: E2 Connection Update procedure, successful operation** + +The Near-RT RIC initiates the procedure by sending a E2 CONNECTION UPDATE message to the E2 Node. The message shall include an appropriate set of up-to-date E2 interface connection data that the E2 Node shall take into account when modifying the E2 interface connection. + +Upon reception of a E2 CONNECTION UPDATE message, the E2 Node shall update as follows: + +- If *E2 Connection To Add List* IE is contained in the E2 CONNECTION UPDATE message, then the E2 Node shall, if supported, use the information to establish additional TNL Association(s) and configure for use for RIC services and/or E2 support functions according to the *TNL Association Usage* IE in the message. +- If *E2 Connection To Modify List* IE is contained in the E2 CONNECTION UPDATE message, then the E2 Node shall, if supported, use the information to modify the existing usage for RIC services and/or E2 support functions, according to the *TNL Association Usage* IE in the message. +- If *E2 Connection To Remove List* IE is contained in the E2 CONNECTION UPDATE message, then the E2 Node shall, if supported, use the information to remove the existing connection(s). If only one connection remains after successful removal of other connections, the E2 Node shall use this remaining connection for all the RIC services and E2 support functions. + +After successful update of E2 interface connection(s), the E2 Node shall reply with the E2 CONNECTION UPDATE ACKNOWLEDGE message to inform the initiating Near-RT RIC that the requested E2 connection update was performed successfully. + +If the E2 Node receives a E2 CONNECTION UPDATE message without any IE except for *Message Type* IE and *Transaction ID* IE, the E2 Node shall reply with the E2 CONNECTION ACKNOWLEDGE message without performing any updates to the existing connections. + +E2 NODE CONFIGURATION UPDATE procedure shall be the first E2AP procedure triggered on an additional TNLA of an already setup E2 interface instance after the TNL association has become operational, and the Near-RT RIC shall associate the TNLA to the E2 interface instance using the included *Global E2 Node ID*. + +An empty E2 NODE CONFIGURATION UPDATE message (i.e. without any IE expect for *Message Type IE* and *Transaction ID IE*) shall be sent by the Near-RT RIC as the first E2AP procedure on the new TNLA, if the E2 Node does not have any Configuration to be updated to Near-RT RIC. + +#### 8.3.6.3 Unsuccessful operation + +![Sequence diagram showing the E2 Connection Update procedure, unsuccessful operation. The diagram shows two instances of 'Near-RT RIC' and 'E2 Node'. A solid arrow labeled 'E2 CONNECTION UPDATE' points from the top 'Near-RT RIC' to the top 'E2 Node'. A dashed arrow labeled 'E2 CONNECTION UPDATE FAILURE' points from the top 'E2 Node' to the bottom 'Near-RT RIC'.](992cfd0e5280a40cdcfb9020f33b69bc_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + + N1->>E1: E2 CONNECTION UPDATE + E1-->N2: E2 CONNECTION UPDATE FAILURE + +``` + +Sequence diagram showing the E2 Connection Update procedure, unsuccessful operation. The diagram shows two instances of 'Near-RT RIC' and 'E2 Node'. A solid arrow labeled 'E2 CONNECTION UPDATE' points from the top 'Near-RT RIC' to the top 'E2 Node'. A dashed arrow labeled 'E2 CONNECTION UPDATE FAILURE' points from the top 'E2 Node' to the bottom 'Near-RT RIC'. + +**Figure 8.3.6.3-1: E2 Connection Update procedure, unsuccessful operation** + +If the E2 Node cannot accept the update, it shall respond with a E2 CONNECTION UPDATE FAILURE message with an appropriate cause value. + +If the E2 CONNECTION UPDATE FAILURE message includes the *Time To Wait IE*, the Near-RT RIC shall wait at least for the indicated time before reinitiating the E2 Connection Update procedure towards the same E2 Node. Both nodes shall continue to operate with their existing connection(s). + +#### 8.3.6.4 Abnormal conditions + +Void. + +### 8.3.7 E2 Removal procedure + +#### 8.3.7.1 General + +The purpose of the E2 removal procedure is to remove the E2 signalling connection between the Near-RT RIC and the E2 node in a controlled manner. + +This procedure shall be initiated by the E2 Node or the Near-RT RIC. + +This procedure uses E2 Support Function signalling. + +#### 8.3.7.2 Successful operation + +This procedure may be initiated by either Near-RT RIC or E2 Node. + +##### Successful E2 Removal, E2 Node initiated + +![Sequence diagram for E2 Removal, successful operation (E2 Node Initiated). The diagram shows two instances of 'Near-RT RIC' and 'E2 Node'. The top instance of 'Near-RT RIC' sends an 'E2 REMOVAL REQUEST' message to the top instance of 'E2 Node'. The top instance of 'E2 Node' then sends an 'E2 REMOVAL RESPONSE' message back to the top instance of 'Near-RT RIC'.](7555580bd5ef3875cc31358e3e751ce3_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + N1-->>E1: E2 REMOVAL REQUEST + E1-->>N1: E2 REMOVAL RESPONSE + +``` + +Sequence diagram for E2 Removal, successful operation (E2 Node Initiated). The diagram shows two instances of 'Near-RT RIC' and 'E2 Node'. The top instance of 'Near-RT RIC' sends an 'E2 REMOVAL REQUEST' message to the top instance of 'E2 Node'. The top instance of 'E2 Node' then sends an 'E2 REMOVAL RESPONSE' message back to the top instance of 'Near-RT RIC'. + +**Figure 8.3.7.2-1: E2 Removal, successful operation (E2 Node Initiated)** + +The E2 Node shall initiate the procedure by sending the E2 REMOVAL REQUEST message to the Near-RT RIC. + +Upon reception of the E2 REMOVAL REQUEST message, the Near-RT RIC shall reply with the E2 REMOVAL RESPONSE message. + +After receiving the E2 REMOVAL RESPONSE message, the E2 Node shall initiate removal of the TNL association towards the Near-RT RIC, and shall release all resources associated with that E2 signalling connection. + +The Near-RT RIC shall then release all resources associated with that E2 signalling connection and erase all application level data. + +##### Successful E2 Removal, Near-RT RIC initiated + +![Sequence diagram for E2 Removal, successful operation (Near-RT RIC Initiated). The diagram shows two instances of 'Near-RT RIC' and 'E2 Node'. The top instance of 'Near-RT RIC' sends an 'E2 REMOVAL REQUEST' message to the top instance of 'E2 Node'. The top instance of 'E2 Node' then sends an 'E2 REMOVAL RESPONSE' message back to the top instance of 'Near-RT RIC'.](7c49c7d46efa13a77606d14ea3118518_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + N1-->>E1: E2 REMOVAL REQUEST + E1-->>N1: E2 REMOVAL RESPONSE + +``` + +Sequence diagram for E2 Removal, successful operation (Near-RT RIC Initiated). The diagram shows two instances of 'Near-RT RIC' and 'E2 Node'. The top instance of 'Near-RT RIC' sends an 'E2 REMOVAL REQUEST' message to the top instance of 'E2 Node'. The top instance of 'E2 Node' then sends an 'E2 REMOVAL RESPONSE' message back to the top instance of 'Near-RT RIC'. + +**Figure 8.3.7.2-2: E2 Removal, successful operation (Near-RT RIC Initiated)** + +The Near-RT RIC shall initiate the procedure by sending the E2 REMOVAL REQUEST message to the E2 node. + +Upon reception of the E2 REMOVAL REQUEST message, the E2 node shall reply with the E2 REMOVAL RESPONSE message. + +After receiving the E2 REMOVAL RESPONSE message, the Near-RT RIC may initiate removal of the TNL association towards the E2 node, and shall release all resources associated with that E2 signalling connection and erase all application level data. + +The E2 node shall then release all resources associated with that E2 signalling connection. + +##### Interactions with other procedures: + +If the E2 REMOVAL REQUEST message is received, any other ongoing procedure on the same E2 interface related to ongoing RIC Services shall be aborted. + +#### 8.3.7.3 Unsuccessful operation + +![Sequence diagram for E2 Removal procedure (E2 Node Initiated), unsuccessful operation. The diagram shows two instances of Near-RT RIC and E2 Node. The top instance shows an E2 Node sending an E2 REMOVAL REQUEST to a Near-RT RIC, which then sends an E2 REMOVAL FAILURE back to the E2 Node. The bottom instance shows a Near-RT RIC sending an E2 REMOVAL REQUEST to an E2 Node, which then sends an E2 REMOVAL FAILURE back to the Near-RT RIC.](d30244318e36e17a0dcde325fbeaa4cb_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + + E1-->>N1: E2 REMOVAL REQUEST + N1-->>E1: E2 REMOVAL FAILURE + + N2-->>E2: E2 REMOVAL REQUEST + E2-->>N2: E2 REMOVAL FAILURE + +``` + +Sequence diagram for E2 Removal procedure (E2 Node Initiated), unsuccessful operation. The diagram shows two instances of Near-RT RIC and E2 Node. The top instance shows an E2 Node sending an E2 REMOVAL REQUEST to a Near-RT RIC, which then sends an E2 REMOVAL FAILURE back to the E2 Node. The bottom instance shows a Near-RT RIC sending an E2 REMOVAL REQUEST to an E2 Node, which then sends an E2 REMOVAL FAILURE back to the Near-RT RIC. + +**Figure 8.3.7.3-1: E2 Removal procedure (E2 Node Initiated), unsuccessful operation** + +![Sequence diagram for E2 Removal procedure (Near-RT RIC Initiated), unsuccessful operation. The diagram shows two instances of Near-RT RIC and E2 Node. The top instance shows a Near-RT RIC sending an E2 REMOVAL REQUEST to an E2 Node, which then sends an E2 REMOVAL FAILURE back to the Near-RT RIC. The bottom instance shows an E2 Node sending an E2 REMOVAL REQUEST to a Near-RT RIC, which then sends an E2 REMOVAL FAILURE back to the E2 Node.](ba293eb5effd848182a005ca9e198324_img.jpg) + +``` + +sequenceDiagram + participant N1 as Near-RT RIC + participant E1 as E2 Node + participant N2 as Near-RT RIC + participant E2 as E2 Node + + N1-->>E1: E2 REMOVAL REQUEST + E1-->>N1: E2 REMOVAL FAILURE + + E2-->>N2: E2 REMOVAL REQUEST + N2-->>E2: E2 REMOVAL FAILURE + +``` + +Sequence diagram for E2 Removal procedure (Near-RT RIC Initiated), unsuccessful operation. The diagram shows two instances of Near-RT RIC and E2 Node. The top instance shows a Near-RT RIC sending an E2 REMOVAL REQUEST to an E2 Node, which then sends an E2 REMOVAL FAILURE back to the Near-RT RIC. The bottom instance shows an E2 Node sending an E2 REMOVAL REQUEST to a Near-RT RIC, which then sends an E2 REMOVAL FAILURE back to the E2 Node. + +**Figure 8.3.7.3-2: E2 Removal procedure (Near-RT RIC Initiated), unsuccessful operation** + +If the E2 Node cannot accept the E2 REMOVAL REQUEST it shall respond with E2 REMOVAL FAILURE message with an appropriate cause value. + +If the Near-RT RIC cannot accept the E2 REMOVAL REQUEST it shall respond with E2 REMOVAL FAILURE message with an appropriate cause value. + +#### 8.3.7.4 Abnormal conditions + +Void. + +# 9 Elements for E2AP communication + +## 9.0 General + +Clauses 9.1 and 9.2 describe the structure of the messages and information elements required for the E2AP protocol in tabular format. Clause 9.3 provides the corresponding ASN.1 definition. + +The following attributes are used for the tabular description of the messages and information elements: Presence, Range Criticality and Assigned Criticality. Their definition and use can be found in 3GPP TS 36.413 [24]. + +**NOTE:** The messages have been defined in accordance with the guidelines specified in 3GPP TR 25.921 [i.2]. + +## 9.1 Message functional definition and content + +### 9.1.1 Messages for RIC Functional procedures + +#### 9.1.1.1 RIC SUBSCRIPTION REQUEST + +This message is sent by the Near-RT RIC to an E2 Node to create a new RIC Subscription in the E2 Node. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------------|----------|---------------------------|-----------------------|--------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| RIC Subscription Details | M | | | | YES | reject | +| >RIC Event Trigger Definition | M | | 9.2.9 | | - | | +| >Sequence of Actions | | 1..<br><maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| >>RIC Action Type | M | | 9.2.11 | | - | | +| >>RIC Action Definition | O | | 9.2.12 | | - | | +| >>RIC Subsequent Action | O | | 9.2.13 | | - | | +| >>RIC Action Execution Order | O | | 9.2.35 | Used to define a specific execution order. | - | | +| RIC Subscription Start Time | O | | 9.2.34 | | YES | reject | +| RIC Subscription End Time | O | | 9.2.34 | | YES | reject | + +| Range bound | Explanation | +|------------------|---------------------------------------------------------------------| +| maxofRICActionID | Maximum no. of Actions to be requested by Near-RT RIC. Value is 16. | + +#### 9.1.1.2 RIC SUBSCRIPTION RESPONSE + +This message is sent by the E2 Node to accept the request from the Near-RT RIC to create a new RIC Subscription in the E2 Node. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------------|----------|---------------------------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| RIC Actions Admitted List | | 1..<br><maxofRICActionID> | | | YES | reject | +| >RIC Action ID | M | | 9.2.10 | | - | | +| RIC Actions Not Admitted List | | 0..<br><maxofRICActionID> | | | YES | reject | +| >RIC Action ID | M | | 9.2.10 | | - | | +| >Cause | M | | 9.2.1 | | - | | + +| Range bound | Explanation | +|------------------|---------------------------------------------------------------------| +| maxofRICActionID | Maximum no. of Actions to be requested by Near-RT RIC. Value is 16. | + +#### 9.1.1.3 RIC SUBSCRIPTION FAILURE + +This message is sent by the E2 Node to inform the Near-RT RIC that the request to create a new RIC Subscription in the E2 Node failed. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | reject | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.1.4 RIC SUBSCRIPTION DELETE REQUEST + +This message is sent by the Near-RT RIC to an E2 Node to request the deletion of an existing Subscription in the E2 Node. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-----------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | + +#### 9.1.1.5 RIC SUBSCRIPTION DELETE RESPONSE + +This message is sent by the E2 Node to accept the request from a Near-RT RIC to delete an existing RIC Subscription in the E2 Node + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-----------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | + +#### 9.1.1.6 RIC SUBSCRIPTION DELETE FAILURE + +This message is sent by the E2 Node to inform the Near-RT RIC that the request to delete an existing RIC Subscription in the E2 Node failed. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | ignore | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.1.6A RIC SUBSCRIPTION DELETE REQUIRED + +This message is sent by the E2 Node to request deletion of the existing RIC Subscriptions in the E2 Node. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-----------------------------------------|----------|----------------------------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| List of RIC Subscriptions To Be Removed | | 1..<br><maxofRICrequestID> | | | EACH | ignore | +| >RIC Request ID | M | | 9.2.7 | | - | - | +| >RAN Function ID | M | | 9.2.8 | | - | - | +| >Cause | M | | 9.2.1 | | - | - | + +| Range bound | Explanation | +|-------------------|-------------------------------------------------------------------------------------------------------| +| maxofRICrequestID | Maximum no. of RIC subscription requests supported by Near-RT RIC toward an E2 Node. Value is <1024>. | + +#### 9.1.1.7 RIC INDICATION + +This message is sent by an E2 Node to transfer Report and Insert RIC Service Action information to a Near-RT RIC. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| RIC Action ID | M | | 9.2.10 | | YES | reject | +| RIC Indication SN | O | | 9.2.14 | | YES | reject | +| RIC Indication Type | M | | 9.2.15 | | YES | reject | +| RIC Indication Header | M | | 9.2.17 | | YES | reject | +| RIC Indication Message | M | | 9.2.16 | | YES | reject | +| RIC Call process ID | O | | 9.2.18 | | YES | reject | + +#### 9.1.1.8 RIC CONTROL REQUEST + +This message is sent by a Near-RT RIC to an E2 Node to initiate or resume a control function logic. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| RIC Call Process ID | O | | 9.2.18 | | YES | reject | +| RIC Control Header | M | | 9.2.20 | | YES | reject | +| RIC Control Message | M | | 9.2.19 | | YES | reject | +| RIC Control Ack Request | O | | 9.2.21 | | YES | reject | + +#### 9.1.1.9 RIC CONTROL ACKNOWLEDGE + +This message is sent by the E2 Node to inform the Near-RT RIC that the RIC CONTROL REQUEST message was received and to provide information on the outcome of the request. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|---------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| RIC Call process ID | O | | 9.2.18 | | YES | reject | +| RIC Control Outcome | O | | 9.2.25 | | YES | reject | + +#### 9.1.1.10 RIC CONTROL FAILURE + +This message is sent by the E2 Node to inform the Near-RT RIC that the RIC CONTROL REQUEST message has failed to be executed. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| RIC Call process ID | O | | 9.2.18 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | ignore | +| RIC Control Outcome | O | | 9.2.25 | | YES | Reject | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.1.11 RIC SUBSCRIPTION MODIFICATION REQUEST + +This message is sent by the Near-RT RIC to an E2 Node to modify an existing Subscription in the E2 Node. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|---------------------------------------------|----------|-----------------------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| RIC Event Trigger Definition to be Modified | O | | 9.2.9 | | YES | ignore | +| <b>RIC Actions to be Removed List</b> | | 0..1 | | | YES | ignore | +| <b>>Action to be Removed Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| <b>RIC Actions to be Modified List</b> | | 0..1 | | | YES | ignore | +| <b>>Action to be Modified Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| >>RIC Action Definition | O | | 9.2.12 | | - | | +| >>RIC Action Execution Order | O | | 9.2.35 | | | | +| >>RIC Subsequent Action | O | | 9.2.13 | | - | | +| <b>RIC Actions to be Added List</b> | | 0..1 | | | YES | ignore | +| <b>>Action to be Added Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| >>RIC Action Type | M | | 9.2.11 | | - | | +| >>RIC Action Definition | M | | 9.2.12 | | - | | +| >>RIC Action Execution Order | M | | 9.2.35 | | | | +| >>RIC Subsequent Action | O | | 9.2.13 | | - | | + +| Range bound | Explanation | +|------------------|---------------------------------------------------------------------| +| maxofRICActionID | Maximum no. of Actions to be requested by Near-RT RIC. Value is 16. | + +#### 9.1.1.12 RIC SUBSCRIPTION MODIFICATION RESPONSE + +This message is sent by the E2 Node to accept the request from the Near-RT RIC to modify an existing E2 subscription in the E2 Node. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|--------------------------------------------------|----------|-----------------------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| <b>RIC Actions Removed List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Removed Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| <b>RIC Actions Failed to be Removed List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Failed to be Removed Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| >>Cause | M | | 9.2.1 | | - | | +| <b>RIC Actions Modified List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Modified Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| <b>RIC Actions Failed to be Modified List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Failed to be Modified Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| >>Cause | M | | 9.2.1 | | - | | +| <b>RIC Actions Added List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Added Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| <b>RIC Actions Failed to be Added List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Failed to be Added Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| >>Cause | M | | 9.2.1 | | - | | + +| Range bound | Explanation | +|------------------|---------------------------------------------------------------------| +| maxofRICActionID | Maximum no. of Actions to be requested by Near-RT RIC. Value is 16. | + +#### 9.1.1.13 RIC SUBSCRIPTION MODIFICATION FAILURE + +This message is sent by the E2 Node to inform the Near-RT RIC that the request to modify an existing E2 subscription in the E2 Node failed. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | reject | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.1.14 RIC SUBSCRIPTION MODIFICATION REQUIRED + +This message is sent by the E2 Node to request the Near-RT RIC to modify an existing E2 subscription in the E2 Node. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|----------------------------------------------------|----------|-----------------------|------------------------------------------------------------------------------------------------------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| <b>RIC Actions Required to be Modified List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Required to be Modified Item IEs</b> | | | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| >>RIC Time to Wait before subsequent action | M | | ENUMERATED<br>(1ms, 2ms, 5ms, 10ms, 20ms, 30ms, 40ms, 50ms, 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 60s, ...) | | - | | +| <b>RIC Actions Required to be Removed List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Required to be Removed Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| >>Cause | M | | 9.2.1 | | - | | + +| Range bound | Explanation | +|------------------|---------------------------------------------------------------------| +| maxofRICActionID | Maximum no. of Actions to be requested by Near-RT RIC. Value is 16. | + +#### 9.1.1.15 RIC SUBSCRIPTION MODIFICATION CONFIRM + +This message is sent by the Near-RT RIC to accept the request from the E2 Node to modify an existing E2 subscription in the E2 Node. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-----------------------------------------------------------|----------|-----------------------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| <b>RIC Actions Confirmed for Modification List</b> | | 0..1 | | | YES | ignore | +| <b>>RIC Action Confirmed for Modification Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| <b>RIC Actions Refused to be Modified List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Refused to be Modified Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| >>Cause | M | | 9.2.1 | | - | | +| <b>RIC Actions Confirmed for Removal List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Confirmed for Removal Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| <b>RIC Actions Refused to be Removed List</b> | | 0..1 | | | YES | ignore | +| <b>>Action Refused to be Removed Item IEs</b> | | 1..<maxofRICactionID> | | | EACH | ignore | +| >>RIC Action ID | M | | 9.2.10 | | - | | +| >>Cause | M | | 9.2.1 | | - | | + +| Range bound | Explanation | +|------------------|---------------------------------------------------------------------| +| maxofRICActionID | Maximum no. of Actions to be requested by Near-RT RIC. Value is 16. | + +#### 9.1.1.16 RIC SUBSCRIPTION MODIFICATION REFUSE + +This message is sent by the Near-RT RIC to deny the request from the E2 Node to modify an existing E2 subscription in the E2 Node. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | reject | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.1.17 RIC QUERY REQUEST + +This message is sent by the Near-RT RIC to an E2 Node to request RAN and/or UE related information from the E2 Node. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|----------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| RIC Query Header | M | | 9.2.36 | | YES | reject | +| RIC Query Definition | M | | 9.2.37 | | YES | reject | + +#### 9.1.1.18 RIC QUERY RESPONSE + +This message is sent by the E2 Node to Near-RT RIC in response to RAN and/or UE related information requested by Near-RT RIC. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| RIC Query Outcome | M | | 9.2.38 | | YES | reject | + +#### 9.1.1.19 RIC QUERY FAILURE + +This message is sent by the E2 Node to inform the Near-RT RIC that the requested RAN and/or UE related Information has failed. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function ID | M | | 9.2.8 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | reject | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.1.20 RIC SUBSCRIPTION AUDIT REQUEST + +This message is sent by the Near-RT RIC to an E2 Node to initiate the RIC Subscription Audit procedure in the E2 Node. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|--------------------------------|----------|--------------------------------|-----------------------|-------------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | RIC Request ID for RIC Subscription Audit procedure. | YES | reject | +| RIC Subscription Audit Flag | O | | 9.2.39 | | YES | reject | +| RIC Subscription Audit List | O | | | | YES | reject | +| >Sequence of RIC Subscriptions | | 1..<br><maxofRICsubscriptions> | | | EACH | ignore | +| >>RIC Request ID | M | | 9.2.7 | RIC Request ID for previously established RIC Subscription. | - | | +| >>RAN Function ID | M | | 9.2.8 | | - | | + +| Range bound | Explanation | +|-----------------------|--------------------------------------------------------------------------------------| +| maxofRICsubscriptions | Maximum no. of RIC Subscriptions to be provided by Near-RT RIC. Value is 2147483648. | + +#### 9.1.1.21 RIC SUBSCRIPTION AUDIT RESPONSE + +This message is sent by the E2 Node to accept the request from the Near-RT RIC to initiate a RIC Subscription Audit in the E2 Node. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|---------------------------------|----------|--------------------------------|-----------------------|-------------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | RIC Request ID for RIC Subscription Audit procedure. | YES | reject | +| RIC Subscription Confirmed List | O | | | | YES | reject | +| >Sequence of RIC Subscriptions | | 1..<br><maxofRICsubscriptions> | | | EACH | ignore | +| >>RIC Request ID | M | | 9.2.7 | RIC Request ID for previously established RIC Subscription. | - | | +| >>RAN Function ID | M | | 9.2.8 | | - | | +| >>RIC Action Admitted List | M | 1..<br><maxofRICactionID> | | | | | +| >>>RIC Action ID | M | | 9.2.10 | | | | +| RIC Subscription Unknown List | O | | | | YES | reject | +| >Sequence of RIC Subscriptions | | 1..<br><maxofRICsubscriptions> | | | EACH | ignore | +| >>RIC Request ID | M | | 9.2.7 | RIC Request ID for previously established RIC Subscription. | - | | +| >>RAN Function ID | M | | 9.2.8 | | - | | +| RIC Subscription Missing List | O | | | | YES | reject | +| >Sequence of RIC Subscriptions | | 1..<br><maxofRICsubscriptions> | | | EACH | ignore | +| >>RIC Request ID | M | | 9.2.7 | RIC Request ID for previously established RIC Subscription. | - | | +| >>RAN Function ID | M | | 9.2.8 | | - | | +| >>RIC Action Admitted List | M | 1..<br><maxofRICactionID> | | | | | +| >>>RIC Action ID | M | | 9.2.10 | | | | + +| Range bound | Explanation | +|-----------------------|--------------------------------------------------------------------------------------| +| maxofRICsubscriptions | Maximum no. of RIC Subscriptions to be provided by Near-RT RIC. Value is 2147483648. | +| maxofRICActionID | Maximum no. of Actions to be requested by Near-RT RIC. Value is 16. | + +#### 9.1.1.22 RIC SUBSCRIPTION AUDIT FAILURE + +This message is sent by the E2 Node to inform the Near-RT RIC that the request to perform the RIC Subscription Audit in the E2 Node failed. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | reject | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.1.23 RIC SERVICE LOAD STATUS REQUEST + +This message is sent by the Near-RT RIC to an E2 Node to request load reporting for one or more RIC Services. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------------------|-----------------------------------------------|---------------------------------|----------------------------------------------|------------------------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Load Measurement ID | M | | 9.2.40 | Allocated by Near-RT RIC | YES | reject | +| E2 Node Load Measurement ID | C-<br>ifRegistrati<br>onRequest<br>StoporAdd | | 9.2.40 | Allocated by E2 Node | YES | ignore | +| Registration Request | M | | ENUMERAT<br>ED (start,<br>stop,<br>add, ...) | Type of request for which the RIC Service Load status is required. | YES | ignore | +| RAN Function Load Request List | C-<br>ifRegistrati<br>onRequest<br>StartorAdd | 1..<br><maxofRANfunc<br>tionID> | | List of RAN functions requested to provide load information | EACH | reject | +| >RAN Function ID | M | | 9.2.8 | Id of the declared Function | - | | +| >RAN Function Load Request | O | | 9.2.43 | Used to request reporting of overall RAN Function load information | - | | +| >RIC Service Load Request | O | | 9.2.44 | Used to request reporting of overall RIC Service load information | - | | +| >RIC Subscription Load Request List | | 0..<br><maxofRICreq<br>uestID> | | | EACH | reject | +| >>RIC Request ID | M | | 9.2.7 | | - | | +| >>RIC Subscription Load Request | O | | 9.2.43 | Used to request reporting of overall RIC Subscription load information | - | | +| >>RIC Action Load Request List | | 0..<br><maxofRICact<br>ionID> | | | EACH | reject | +| >>>RIC Action ID | M | | 9.2.10 | | - | | +| >>>RIC Action Load Request | M | | 9.2.43 | Used to request reporting of overall RIC Action load information | - | | + +| | | | | | | | +|-----------------------|---|--|----------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----|--------| +| Reporting Periodicity | O | | ENUMERATED (500ms, 1000ms, 2000ms, 5000ms, 10000ms, ...) | Periodicity that can be used for reporting of indicated measurements. Also used as the averaging window length for all measurement object if supported. This IE is ignored if the Registration Request IE is set to "add". | YES | ignore | +|-----------------------|---|--|----------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----|--------| + +| Condition | Explanation | +|---------------------------------|------------------------------------------------------------------------------------------------------| +| ifRegistrationRequestStoporAdd | This IE shall be present if the <i>Registration Request</i> IE is set to the value "stop" or "add". | +| ifRegistrationRequestStartorAdd | This IE shall be present if the <i>Registration Request</i> IE is set to the value "start" or "add". | + +| Range bound | Explanation | +|--------------------|-------------------------------------------------------------------------------------------------------| +| maxofRANfunctionID | Maximum no. of RAN Functions supported by E2 Node. Value is 256. | +| maxofRICrequestID | Maximum no. of RIC subscription requests supported by Near-RT RIC toward an E2 Node. Value is <1024>. | +| maxofRICActionID | Maximum no. of Actions to be requested by Near-RT RIC. Value is 16. | + +#### 9.1.2.24 RIC SERVICE LOAD STATUS RESPONSE + +This message is sent by the E2 Node to the Near-RT RIC to accept the request for load reporting for one or more RIC Services. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------------------|-----------------------------------------------|---------------------------------|-----------------------|-------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Load Measurement ID | M | | 9.2.40 | Allocated by Near-RT RIC | YES | reject | +| E2 Node Load Measurement ID | M | | 9.2.40 | Allocated by E2 Node | YES | ignore | +| RAN Function Load Confirm List | C-<br>ifRegistrati<br>onRequest<br>StartorAdd | 1..<br><maxofRANfunct<br>ionID> | | List of RAN functions | EACH | reject | +| >RAN Function ID | M | | 9.2.8 | Id of the declared Function | - | | +| >RAN Function Load Confirm | O | | 9.2.45 | Used to confirm RAN Function level load reporting | - | | +| >RIC Service Load Confirm | O | | 9.2.46 | Used to confirm RIC Service load reporting | - | | +| >RIC Subscription Load Confirm List | | 0..<br><maxofRICreq<br>uestID> | | | EACH | reject | +| >>RIC Request ID | M | | 9.2.7 | | - | | +| >>RIC Subscription Load Confirm | O | | 9.2.45 | Used to confirm RIC Subscription level load reporting | - | | +| >>RIC Action List | | 0..<br><maxofRICact<br>ionID> | | | EACH | reject | +| >>>RIC Action ID | M | | 9.2.10 | | - | | +| >>>RIC Action Load Confirm | M | | 9.2.45 | Used to confirm RIC Action level load reporting | - | | + +| Condition | Explanation | +|---------------------------------|------------------------------------------------------------------------------------------------------------------------------------------| +| ifRegistrationRequestStartorAdd | This IE shall be present if the <i>Registration Request</i> IE in RIC SERVICE LOAD STATUS REQUEST was set to the value "start" or "add". | + +#### 9.1.2.25 RIC SERVICE LOAD STATUS FAILURE + +This message is sent by the E2 Node to inform the Near-RT RIC that the request for load reporting for one or more RIC Services failed. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-----------------------------|----------|-------|-----------------------|--------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Load Measurement ID | M | | 9.2.40 | Allocated by Near-RT RIC | YES | reject | +| E2 Node Load Measurement ID | M | | 9.2.40 | Allocated by E2 Node | YES | ignore | +| Cause | M | | 9.2.1 | | YES | ignore | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.1.26 RIC SERVICE LOAD UPDATE + +This message is sent by an E2 Node to a Near-RT RIC to transfer RIC Service load status information. + +Direction: E2 Node → Near-RT RIC + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------------------|----------|-----------------------------|-----------------------|-----------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Load Measurement ID | M | | 9.2.40 | Allocated by Near-RT RIC | YES | reject | +| E2 Node Load Measurement ID | M | | 9.2.40 | Allocated by E2 Node | YES | ignore | +| RAN Function Load List | | 1..<br><maxofRANfunctionID> | | List of RAN functions with load information | EACH | reject | +| >RAN Function ID | M | | 9.2.8 | Id of the declared Function | - | | +| >RAN Function Load Information | O | | 9.2.41 | Used to provide overall RAN Function load information | - | | +| >RIC Service Load Information | O | | 9.2.42 | Used to provide overall RIC Service load information | - | | +| >RIC Subscription Load List | | 0..<br><maxofRICrequestID> | | | EACH | reject | +| >>RIC Request ID | M | | 9.2.7 | | - | | +| >>RIC Subscription Load Information | O | | 9.2.41 | Used to provide overall RIC Subscription load information | - | | +| >>RIC Action Load List | | 0..<br><maxofRICactionID> | | | EACH | reject | +| >>>RIC Action ID | M | | 9.2.10 | | - | | +| >>>RIC Action Load Information | M | | 9.2.41 | Used to provide overall RIC Action load information | - | | + +| Range bound | Explanation | +|--------------------|-------------------------------------------------------------------------------------------------------| +| maxofRANfunctionID | Maximum no. of RAN Functions supported by E2 Node. Value is 256. | +| maxofRICrequestID | Maximum no. of RIC subscription requests supported by Near-RT RIC toward an E2 Node. Value is <1024>. | +| maxofRICActionID | Maximum no. of Actions to be requested by Near-RT RIC. Value is 16. | + +#### 9.1.1.27 RIC SUBSCRIPTION STATE CONTROL REQUEST + +This message is sent by the Near-RT RIC to an E2 Node to suspend and/or resume one or more RIC Subscriptions. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|----------------------------------------|----------|-----------------------------|-----------------------|---------------------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function State Control List | | 1..<br><maxofRANfunctionID> | | List of RAN functions with RIC subscriptions | EACH | reject | +| >RAN Function ID | M | | 9.2.8 | Id of the declared Function | - | | +| >RIC Subscription To Be Suspended List | | 0..<br><maxofRICrequestID> | | | EACH | reject | +| >>RIC Request ID | M | | 9.2.7 | RIC Request ID of RIC Subscription to be suspended | - | | +| >>RIC Action List | | 0..<br><maxofRICActionID> | | If present, then only the nominated RIC Actions are to be suspended | EACH | reject | +| >>>RIC Action ID | M | | 9.2.10 | | - | | +| >RIC Subscription To Be Resumed List | | 0..<br><maxofRICrequestID> | | | EACH | reject | +| >>RIC Request ID | M | | 9.2.7 | RIC Request ID of RIC Subscription to be resumed | - | | +| >>RIC Action List | | 0..<br><maxofRICActionID> | | If present, then only the nominated RIC Actions are to be resumed | EACH | reject | +| >>>RIC Action ID | M | | 9.2.10 | | - | | + +| Range bound | Explanation | +|--------------------|-------------------------------------------------------------------------------------------------------| +| maxofRANfunctionID | Maximum no. of RAN Functions supported by E2 Node. Value is 256. | +| maxofRICrequestID | Maximum no. of RIC subscription requests supported by Near-RT RIC toward an E2 Node. Value is <1024>. | + +#### 9.1.1.28 RIC SUBSCRIPTION STATE CONTROL RESPONSE + +This message is sent by the E2 Node to the Near-RT RIC to accept the request to suspend and/or resume one or more RIC Subscriptions. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|----------------------------------|----------|-----------------------------|-----------------------|----------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RAN Function State Confirm List | | 1..<br><maxofRANfunctionID> | | List of RAN functions with RIC subscriptions | EACH | reject | +| >RAN Function ID | M | | 9.2.8 | Id of the declared Function | - | | +| >RIC Subscription Suspended List | | 0..<br><maxofRICrequestID> | | | EACH | reject | +| >>RIC Request ID | M | | 9.2.7 | RIC Request ID of suspended RIC Subscription | - | | +| >>RIC Action List | | 0..<br><maxofRICactionID> | | | EACH | reject | +| >>>RIC Action ID | M | | 9.2.10 | | - | | +| >RIC Subscription Resumed List | | 0..<br><maxofRICrequestID> | | | EACH | reject | +| >>RIC Request ID | M | | 9.2.7 | RIC Request ID of resumed RIC Subscription | - | | +| >>RIC Action List | | 0..<br><maxofRICactionID> | | | EACH | reject | +| >>>RIC Action ID | M | | 9.2.10 | | - | | + +#### 9.1.1.29 RIC SUBSCRIPTION STATE CONTROL FAILURE + +This message is sent by the E2 Node to inform the Near-RT RIC that the request to suspend and/or resume one or more RIC Subscriptions in the E2 Node failed. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | reject | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.1.30 RIC ASSISTANCE REQUEST + +This message is sent by the E2 Node to Near-RT RIC to request an assistance service. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RIC Assistance Header | M | | 9.2.47 | | YES | reject | +| RIC Assistance Message | M | | 9.2.48 | | YES | reject | +| RIC Assistance Update | O | | 9.2.49 | | YES | ignore | +| RIC Assistance Update Number | O | | 9.2.50 | | YES | ignore | + +#### 9.1.1.31 RIC ASSISTANCE RESPONSE + +This message is sent by the Near-RT RIC to the E2 Node to provide the requested assistance service. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RIC Assistance Header | M | | 9.2.47 | | YES | reject | +| RIC Assistance Outcome | M | | 9.2.51 | | YES | ignore | + +#### 9.1.1.32 RIC ASSISTANCE FAILURE + +This message is sent by the Near-RT RIC to inform the E2 Node that the requested RIC Assistance service failed. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | reject | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.1.33 RIC ASSISTANCE INDICATION + +This message is sent by the Near-RT RIC to the E2 Node to provide an updated response to the requested assistance service. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | reject | +| RIC Assistance SN | M | | 9.2.52 | | YES | ignore | +| RIC Assistance Header | M | | 9.2.47 | | YES | reject | +| RIC Assistance Outcome | M | | 9.2.51 | | YES | ignore | + +#### 9.1.1.34 RIC ASSISTANCE HALT + +This message is sent by the E2 Node to the Near-RT RIC to halt further updates to the requested assistance service. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|----------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| RIC Request ID | M | | 9.2.7 | | YES | ignore | + +### 9.1.2 Messages for Global Procedures + +#### 9.1.2.1 ERROR INDICATION + +This message is used to indicate that some error has been detected in the E2 Node or Near-RT RIC. + +Direction: E2 Node → Near-RT RIC or Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | ignore | +| Transaction ID | O | | 9.2.33 | Required if <i>RIC Request ID</i> IE is not present. | YES | reject | +| RIC Request ID | O | | 9.2.7 | Required if <i>Transaction ID</i> IE is not present. | YES | reject | +| RAN Function ID | O | | 9.2.8 | | YES | reject | +| Cause | O | | 9.2.1 | | YES | ignore | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.2.2 E2 SETUP REQUEST + +This message is sent by an E2 Node to a Near-RT RIC to transfer the initialization information. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------------------------------------|----------|--------------------------------|-----------------------|------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | . | YES | reject | +| Global E2 Node ID | M | | 9.2.6 | | YES | reject | +| <b>RAN Functions Added List</b> | | 1 | | List of RAN functions in E2 node. | YES | reject | +| >RAN Function item | | 1..<br><maxofRANfunctionID> | | | | | +| >>RAN Function ID | M | | 9.2.8 | Id of the declared Function. | - | | +| >>RAN Function Definition | M | | 9.2.23 | Definition of Function. | - | | +| >>RAN Function Revision | M | | 9.2.24 | Revision counter. | - | | +| >>RAN Function OID | M | | 9.2.31 | Object identifier of corresponding E2SM. | - | | +| <b>E2 Node Component Configuration Addition List</b> | | 1 | | List of E2 Node component configuration information. | YES | reject | +| >E2 Node Component Configuration Addition Item | | 1..<br><maxofE2nodeComponents> | | | EACH | reject | +| >>E2 Node Component Interface Type | M | | 9.2.26 | E2 Node component interface type. | - | | +| >>E2 Node Component ID | O | | 9.2.32 | E2 Node Component Identifier. | - | | +| >>E2 Node Component Configuration | M | | 9.2.27 | Contents depends on component interface type. | - | | + +| Range bound | Explanation | +|-----------------------|-----------------------------------------------------------------------| +| maxofRANfunctionID | Maximum no. of RAN Functions supported by E2 Node. Value is 256. | +| maxofE2nodeComponents | Maximum no. of E2 Node components supported by E2 Node. Value is 1024 | + +#### 9.1.2.3 E2 SETUP RESPONSE + +This message is sent by a Near-RT RIC to an E2 Node to transfer the initialization information. + +Direction: Near-RT RIC →E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------------------------------------------------|----------|--------------------------------|-----------------------|----------------------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | . | YES | reject | +| Global RIC ID | M | | 9.2.4 | | YES | reject | +| <b>RAN Functions Accepted List</b> | | 0..1 | | Complete list of Functions accepted by Near-RT RIC. | | | +| >RAN Functions ID item | | 1 ..<br><maxofRANfunctionID> | | | YES | Reject | +| >>RAN Function ID | M | | 9.2.8 | Id of the declared Function. | - | | +| >>RAN Function Revision | M | | 9.2.24 | Revision counter. | - | | +| <b>RAN Functions Rejected List</b> | | 0..1 | | Complete list of Functions not accepted by Near-RT RIC. | | | +| >RAN Functions ID Cause Item | | 1 ..<br><maxofRANfunctionID> | | | YES | reject | +| >>RAN Function ID | M | | 9.2.8 | Id of the declared Function. | - | | +| >>Cause | M | | 9.2.1 | Reason for not accepting function. | - | | +| <b>E2 Node Component Configuration Addition Acknowledge List</b> | | 1 | | Complete list of E2 Node Components in the E2 SETUP REQUEST message. | YES | reject | +| >E2 Node Component Configuration Addition Acknowledge Item | | 1..<br><maxofE2nodeComponents> | | | EACH | reject | +| >>E2 Node Component Interface Type | M | | 9.2.26 | E2 Node component interface type. | - | | +| >>E2 Node Component ID | M | | 9.2.32 | E2 Node Component Identifier. | - | | +| >>E2 Node Component Configuration Acknowledge | M | | 9.2.28 | Success or failure with Cause. | - | | + +| Range bound | Explanation | +|-----------------------|-----------------------------------------------------------------------| +| maxofRANfunctionID | Maximum no. of RAN Functions supported by E2 Node. Value is 256. | +| maxofE2nodeComponents | Maximum no. of E2 Node components supported by E2 Node. Value is 1024 | + +#### 9.1.2.4 E2 SETUP FAILURE + +This message is sent by the Near-RT RIC to indicate E2 Setup failure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-----------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | ignore | +| Time To Wait | O | | 9.2.5 | | YES | ignore | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | +| Transport Layer Information | O | | 9.2.29 | | YES | ignore | + +#### 9.1.2.5 RESET REQUEST + +This message is sent from a Near-RT RIC to an E2 Node or from an E2 Node to a Near-RT RIC and is used to request the E2 interface between the E2 node and the Near-RT RIC to be reset. + +Direction: Near-RT RIC → E2 Node, or E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|----------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | ignore | + +#### 9.1.2.6 RESET RESPONSE + +This message is sent by an E2 Node to a Near-RT RIC or from a Near-RT RIC to an E2 Node as a response to a RESET REQUEST message. + +Direction: Near-RT RIC → E2 Node, or E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.2.7 RIC SERVICE UPDATE + +This message is sent by an E2 Node to the Near-RT RIC to transfer updated information on RIC Services supported by the E2 Node. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------------------|----------|------------------------------|-----------------------|--------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| <b>RAN Functions Added List</b> | | 0..1 | | List of added RAN functions in E2 node. | | | +| >RAN Functions Item | | 1 ..<br><maxofRANfunctionID> | | | YES | reject | +| >>RAN Function ID | M | | 9.2.8 | Id of the declared Function. | - | | +| >>RAN Function Definition | M | | 9.2.23 | Definition of Function. | - | | +| >>RAN Function Revision | M | | 9.2.24 | Revision counter. | - | | +| >>RAN Function OID | M | | 9.2.31 | Object identifier of corresponding E2SM. | - | | +| <b>RAN Functions Modified List</b> | | 0..1 | | List of Modified RAN functions in E2 node. | | | +| >RAN Functions Item | | 1 ..<br><maxofRANfunctionID> | | | YES | reject | +| >>RAN Function ID | M | | 9.2.8 | Id of the declared Function. | - | | +| >>RAN Function Definition | M | | 9.2.23 | Definition of Function. | - | | +| >>RAN Function Revision | M | | 9.2.24 | Revision counter. | - | | +| >>RAN Function OID | M | | 9.2.31 | Object identifier of corresponding E2SM. | - | | +| <b>RAN Functions Deleted List</b> | | 0..1 | | List of deleted RAN functions in E2 node. | | | +| >RAN Functions ID Item | | 1 ..<br><maxofRANfunctionID> | | | YES | reject | +| >>RAN Function ID | M | | 9.2.8 | Id of the declared Function. | - | | +| >>RAN Function Revision | M | | 9.2.24 | Revision counter. | - | | + +| Range bound | Explanation | +|--------------------|-----------------------------------------------------------------| +| maxofRANfunctionID | Maximum no. of Functions accepted by Near-RT RIC. Value is 256. | + +#### 9.1.2.8 RIC SERVICE UPDATE ACKNOWLEDGE + +This message is sent by the Near-RT RIC to the E2 Node to acknowledge update of RIC Services supported by the E2 Node. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------------------|----------|------------------------------|-----------------------|------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| <b>RAN Functions Accepted List</b> | | 0..1 | | List of Functions accepted by Near-RT RIC. | | | +| >RAN Functions ID Item | | 1 ..<br><maxofRANfunctionID> | | | YES | reject | +| >>RAN Function ID | M | | 9.2.8 | Id of the declared Function. | - | | +| >>RAN Function Revision | M | | 9.2.24 | Revision counter. | - | | +| <b>RAN Functions Rejected List</b> | | 0..1 | | List of Functions not accepted by Near-RT RIC. | | | +| >RAN Functions Cause Item | | 1 ..<br><maxofRANfunctionID> | | | YES | reject | +| >>RAN Function ID | M | | 9.2.8 | Id of the declared Function. | - | | +| >>Cause | M | | 9.2.1 | Reason for not accepting function. | - | | + +| Range bound | Explanation | +|--------------------|-----------------------------------------------------------------| +| maxofRANfunctionID | Maximum no. of Functions accepted by Near-RT RIC. Value is 256. | + +#### 9.1.2.9 RIC SERVICE UPDATE FAILURE + +This message is sent by the Near-RT RIC to the E2 Node to indicate RIC SERVICE Update Failure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| Cause | M | | 9.2.1 | Reason for failure. | YES | reject | +| Time To Wait | O | | 9.2.5 | | YES | ignore | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.2.10 RIC SERVICE QUERY + +This message is sent by a Near-RT RIC to an E2 Node to request a E2 Node initiated RIC Service Update procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------------------|----------|----------------------------------------|-----------------------|----------------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | . | YES | reject | +| <b>RAN Functions Accepted List</b> | | 0..1 | | Complete list of Functions previously accepted by Near-RT RIC. | | | +| >RAN Functions ID Item | | 1 .. <i><maxofRANfunctionID></i> | | | YES | reject | +| >>RAN Function ID | M | | 9.2.8 | Id of the declared Function. | - | | +| >>RAN Function Revision | M | | 9.2.24 | Revision counter. | - | | + +| Range bound | Explanation | +|--------------------|-----------------------------------------------------------------| +| maxofRANfunctionID | Maximum no. of Functions accepted by Near-RT RIC. Value is 256. | + +#### 9.1.2.11 E2 NODE CONFIGURATION UPDATE + +This message is sent by an E2 Node to the Near-RT RIC to transfer updated information on the E2 Node Configuration information. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------------------------------------|----------|------------------------------------|-----------------------|-------------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| Global E2 Node ID | O | | 9.2.6 | Required when sent as first message on new TNL association. | YES | reject | +| <b>E2 Node Component Configuration Addition List</b> | | 0..1 | | | YES | reject | +| >E2 Node Component Configuration Addition Item | | 1..<br><maxofE2nodeC<br>omponents> | | | EACH | reject | +| >>E2 Node Component Interface Type | M | | 9.2.26 | E2 Node component interface type. | - | | +| >>E2 Node Component ID | M | | 9.2.32 | E2 Node Component Identifier. | - | | +| >>E2 Node Component Configuration | M | | 9.2.27 | Contents depends on component type. | - | | +| <b>E2 Node Component Configuration Update List</b> | | 0..1 | | | YES | reject | +| >E2 Node Component Configuration Update Item | | 1..<br><maxofE2nodeC<br>omponents> | | | EACH | reject | +| >>E2 Node Component Interface Type | M | | 9.2.26 | E2 Node component interface type. | - | | +| >>E2 Node Component ID | M | | 9.2.32 | E2 Node Component Identifier. | - | | +| >>E2 Node Component Configuration | M | | 9.2.27 | Contents depends on component type. | - | | +| <b>E2 Node Component Configuration Removal List</b> | | 0..1 | | | YES | reject | +| >E2 Node Component Configuration Removal Item | | 1..<br><maxofE2nodeC<br>omponents> | | | EACH | reject | +| >>E2 Node Component Interface Type | M | | 9.2.26 | E2 Node component interface type. | - | | +| >>E2 Node Component ID | M | | 9.2.32 | E2 Node Component Identifier. | - | | +| <b>E2 Node TNL Association To Remove List</b> | | 0..1 | | | YES | reject | +| >E2 Node TNL Association To Remove Item IEs | | 1..<br><maxofTNLA> | | | EACH | reject | + +| | | | | | | | +|--------------------------------------------|---|--|--------|---------------------------------------------|---|---| +| >> Transport Layer Information | M | | 9.2.29 | Transport Layer Address of the E2 node. | - | - | +| >> Transport Layer Information Near-RT RIC | O | | 9.2.29 | Transport Layer Address of the Near-RT RIC. | - | - | + +| Range bound | Explanation | +|-----------------------|------------------------------------------------------------------------| +| maxofE2nodeComponents | Maximum no. of E2 Node components supported by E2 Node. Value is 1024. | +| maxofTNLA | Maximum no. of TNL Associations supported by E2 Node. Value is 32. | + +#### 9.1.2.12 E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE + +This message is sent by Near-RT RIC to E2 Node to acknowledge update of E2 Node Configuration supported by the E2 Node. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|------------------------------------------------------------------|----------|---------------------------------|-----------------------|-----------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | . | YES | reject | +| <b>E2 Node Component Configuration Addition Acknowledge List</b> | | 0..1 | | | YES | reject | +| >E2 Node Component Configuration Addition Acknowledge Item | | 1..<br><maxofE2node Components> | | | EACH | reject | +| >>E2 Node Component Interface Type | M | | 9.2.26 | E2 Node component interface type. | - | | +| >>E2 Node Component ID | M | | 9.2.32 | E2 Node Component Identifier. | - | | +| >>E2 Node Component Configuration Acknowledge | M | | 9.2.28 | Success or failure with Cause. | - | | +| <b>E2 Node Component Configuration Update Acknowledge List</b> | | 0..1 | | | YES | reject | +| >E2 Node Component Configuration Update Acknowledge Item | | 1..<br><maxofE2node Components> | | | EACH | reject | +| >>E2 Node Component Interface Type | M | | 9.2.26 | E2 Node component interface type. | - | | +| >>E2 Node Component ID | O | | 9.2.32 | E2 Node Component Identifier. | - | | +| >>E2 Node Component Configuration Update Acknowledge | M | | 9.2.28 | Success or failure with Cause. | - | | +| <b>E2 Node Component Configuration Removal Acknowledge List</b> | | 0..1 | | | YES | reject | +| >E2 Node Component Configuration Removal Acknowledge Item | | 1..<br><maxofE2node Components> | | | EACH | reject | +| >>E2 Node Component Interface Type | M | | 9.2.26 | E2 Node component interface type. | - | | +| >>E2 Node Component ID | M | | 9.2.32 | E2 Node Component Identifier. | - | | +| >>E2 Node Component Configuration Acknowledge | M | | 9.2.28 | Success or failure with Cause. | - | | + +| Range bound | Explanation | +|-----------------------|------------------------------------------------------------------------| +| maxofE2nodeComponents | Maximum no. of E2 Node components supported by E2 Node. Value is 1024. | + +#### 9.1.2.13 E2 NODE CONFIGURATION UPDATE FAILURE + +This message is sent by Near-RT RIC to E2 Node to indicate E2 Node Configuration Update Failure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | . | YES | reject | +| Cause | M | | 9.2.1 | Cause | YES | reject | +| Time To Wait | O | | 9.2.5 | | YES | ignore | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.2.14 E2 CONNECTION UPDATE + +This message is sent by Near-RT RIC to E2 Node to initiate update of E2 Connection supported by the E2 Node. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------------------|----------|-----------------------------|-----------------------|---------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| <b>E2 Connection To Add List</b> | | 0..1 | | | YES | ignore | +| >E2 Connection to Add Item IEs | | 1..<br>< <i>maxofTNLA</i> > | | | EACH | ignore | +| >>Transport Layer Information | M | | 9.2.29 | Transport layer address and port number of Near-RT RIC. | | | +| >>TNL Association Usage | M | | 9.2.30 | Indicates how E2 connection is to be used. | | | +| <b>E2 Connection To Remove List</b> | | 0..1 | | | YES | ignore | +| >E2 Connection to Remove Item IEs | | 1..<br>< <i>maxofTNLA</i> > | | | EACH | ignore | +| >>Transport Layer Information | M | | 9.2.29 | Transport layer address and port number of Near-RT RIC. | | | +| <b>E2 Connection To Modify List</b> | | 0..1 | | | YES | ignore | +| >E2 Connection to Modify Item IEs | | 1..<br>< <i>maxofTNLA</i> > | | | EACH | ignore | +| >>Transport Layer Information | M | | 9.2.29 | Transport layer address and port number of Near-RT RIC. | | | +| >>TNL Association Usage | M | | 9.2.30 | Indicates how E2 connection is to be used. | | | + +| Range bound | Explanation | +|-------------|--------------------------------------------------------------------| +| maxofTNLA | Maximum no. of TNL Associations supported by E2 Node. Value is 32. | + +#### 9.1.2.15 E2 CONNECTION UPDATE ACKNOWLEDGE + +This message is sent by E2 Node to the Near-RT RIC to acknowledge update of E2 Connection supported by the E2 Node. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------------------------|----------|--------------------|-----------------------|---------------------------------------------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| <b>E2 Connection Setup List</b> | | 0..1 | | | YES | ignore | +| >E2 Connection Setup Item IEs | | 1..<br><maxofTNLA> | | | EACH | ignore | +| >>Transport Layer Information | M | | 9.2.29 | Transport layer address and port number of Near-RT RIC. | | | +| >>TNL Association Usage | M | | 9.2.30 | Indicates how E2 connection is to be used. | | | +| <b>E2 Connection Failed to Setup List</b> | | 0..1 | | | YES | ignore | +| >E2 Connection failed to setup Item IEs | | 1..<br><maxofTNLA> | | | EACH | ignore | +| >>Transport Layer Information | M | | 9.2.29 | Transport layer address and port number of Near-RT RIC. | | | +| >>Cause | M | | 9.2.1 | | | | + +| Range bound | Explanation | +|-------------|--------------------------------------------------------------------| +| maxofTNLA | Maximum no. of TNL Associations supported by E2 Node. Value is 32. | + +#### 9.1.2.16 E2 CONNECTION UPDATE FAILURE + +This message is sent by E2 Node to the Near-RT RIC to inform failure of the requested E2 Connection updates. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | reject | +| Time To Wait | O | | 9.2.5 | | YES | ignore | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.2.17 E2 REMOVAL REQUEST + +This message is sent by either the E2 Node or the Near-RT RIC to initiate the removal of the E2 signalling connection and the related resources. + +Direction: Near-RT RIC → E2 Node, or E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|----------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | + +#### 9.1.2.18 E2 REMOVAL RESPONSE + +This message is sent by either the E2 Node or the Near-RT RIC to acknowledge the initiation of removal of the E2 signalling connection and the related resources. + +Direction: Near-RT RIC → E2 Node, or E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +#### 9.1.2.19 E2 REMOVAL FAILURE + +This message is sent by either the E2 Node or the Near-RT RIC to indicate that removing the E2 signalling connection and the related resources cannot be accepted. + +Direction: Near-RT RIC → E2 Node, or E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | Criticality | Assigned Criticality | +|-------------------------|----------|-------|-----------------------|-----------------------|-------------|----------------------| +| Message Type | M | | 9.2.3 | | YES | reject | +| Transaction ID | M | | 9.2.33 | | YES | reject | +| Cause | M | | 9.2.1 | | YES | ignore | +| Criticality Diagnostics | O | | 9.2.2 | | YES | ignore | + +## 9.2 Information Element definitions + +### 9.2.0 General + +When specifying information elements which are to be represented by bit strings, if not otherwise specifically stated in the semantics description of the concerned IE or elsewhere, the following principle applies with regards to the ordering of bits: + +- The first bit (leftmost bit) contains the Most Significant Bit (MSB); +- The last bit (rightmost bit) contains the Least Significant Bit (LSB); +- When importing bit strings from other specifications, the first bit of the bit string contains the first bit of the concerned information. + +### 9.2.1 Cause + +The purpose of the *Cause* IE is to indicate the reason for a particular event for the E2AP protocol. + +| IE/Group Name | Presence | Range | IE Type and Reference | Semantics Description | +|-------------------------|----------|-------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| +| CHOICE Cause Group | M | | | | +| >RIC services | | | | | +| >>RIC Request | O | | ENUMERATED<br>(RAN Function ID invalid,<br>Action not supported,<br>Excessive actions,<br>Duplicate action,<br>Duplicate Event Trigger,<br>Function resource limit,<br>RIC Request ID unknown,<br>Inconsistent Action/subsequent Action sequence,<br>Control message invalid,<br>RIC Call process ID invalid,<br>Control timer expired,<br>Control failed to execute,<br>System not ready,<br>unspecified, ...,<br>RIC Subscription End Time expired,<br>RIC Subscription Time invalid,<br>Duplicate RIC Request ID,<br>Event Trigger not supported,<br>Requested Information Unavailable,<br>Invalid Information Request) | | +| >>RIC Service | O | | ENUMERATED<br>(RAN Function not supported,<br>Excessive functions,<br>RIC resource limit, ...) | | +| >>E2 Node | O | | ENUMERATED<br>(E2 node component unknown, ...) | | +| >Transport Layer | | | | | +| >>Transport Layer Cause | M | | ENUMERATED<br>(Unspecified,<br>Transport Resource Unavailable, ...) | | +| >Protocol | | | | | +| >>Protocol Cause | M | | ENUMERATED<br>(Transfer Syntax Error,<br>Abstract Syntax Error (Reject),<br>Abstract Syntax Error (Ignore and Notify),<br>Message not Compatible with Receiver State,<br>Semantic Error,<br>Abstract Syntax Error (Falsely Constructed Message),<br>Unspecified, ...) | | +| >Misc | | | | | +| >>Miscellaneous Cause | M | | ENUMERATED<br>(Control Processing Overload,<br>Hardware Failure,<br>O&M Intervention,<br>Unspecified, ...) | | +| >Service layer | | | | | +| >>Service layer Cause | M | | 9.2.53 | | + +The meaning of the different cause values is described in the following table. In general, "not supported" cause values indicate that the related capability is missing. On the other hand, "not available" cause values indicate that the related capability is present, but insufficient resources are available to perform the requested action. + +| <b>RIC Request cause</b> | <b>Meaning</b> | +|------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------| +| Unspecified | Sent for RIC service cause when none of the specified cause values applies. | +| RAN Function ID invalid | Requested function Id invalid or not known by E2 Node. | +| Action not supported | Requested Action not supported by RAN function. | +| Excessive actions | Excessive number of actions requested for RAN Function. | +| Duplicate action | Same action requested more than once in same subscription request. | +| Duplicate Event Trigger | Subscription request has same event trigger as previously accepted subscription request. | +| Function resource limit | RAN function has reached resource limit. | +| RIC Request ID unknown | RIC Request ID sent to Near-RT RIC is unknown. | +| Inconsistent Action/subsequent Action sequence | RAN Function has detected inconsistent sequence of requested Action and Subsequent Action. | +| Control message invalid | RAN Function has detected invalid RIC CONTROL REQUEST message. | +| RIC Call process ID invalid | RAN function has detected invalid RIC Call Process ID in RIC CONTROL REQUEST. | +| Control timer expired | RIC Control Request received by E2 Node after the associated RIC Time to Wait timer had expired. | +| Control failed to execute | Requested control procedure initiated by RIC Control Request failed to be executed in the E2 Node. | +| System not ready | RAN Function is not ready to receive RIC Subscription or RIC Control message. | +| RIC Subscription End Time expired | RIC SUBSCRIPTION DELETE REQUIRED is triggered to inform Near-RT RIC that end time has expired. | +| RIC Subscription Time invalid | E2 Node received RIC SUBSCRIPTION REQUEST containing an invalid RIC Subscription Start Time and/or RIC Subscription End Time. | +| Duplicate RIC Request ID | E2 node does not support handling of same RIC Request ID as previously accepted subscription request. | +| Event Trigger not supported | Requested event trigger definition or modification - not supported by RAN function. | +| Requested Information Unavailable | Information requested by Near-RT RIC is not available at E2 Node. | +| Invalid Information Request | Information requested by Near-RT RIC is invalid. | + +| <b>RIC Service cause</b> | <b>Meaning</b> | +|----------------------------|------------------------------------------------------------------------| +| RAN Function not supported | The RAN Function described by E2 Node is not supported by Near-RT RIC. | +| Excessive functions | RIC has reached a limit on the number of declared RAN functions. | +| RIC resource limit | RIC has reached a resource limit. | + +| <b>E2 Node configuration cause</b> | <b>Meaning</b> | +|------------------------------------|--------------------------------------------------------------| +| E2 Node component unknown | The received message refers to an unknown E2 Node component. | + +| <b>Transport Layer cause</b> | <b>Meaning</b> | +|--------------------------------|----------------------------------------------------------------------------------------------------------| +| Unspecified | Sent when none of the cause values below applies but still the cause is Transport Network Layer related. | +| Transport Resource Unavailable | The required transport resources are not available. | + +| Protocol cause | Meaning | +|-----------------------------------------------------|----------------------------------------------------------------------------------------------------------------------| +| Transfer Syntax Error | The received message included a transfer syntax error. | +| Abstract Syntax Error (Reject) | The received message included an abstract syntax error and the concerning criticality indicated "reject". | +| Abstract Syntax Error (Ignore And Notify) | The received message included an abstract syntax error and the concerning criticality indicated "ignore and notify". | +| Message Not Compatible With Receiver State | The received message was not compatible with the receiver state. | +| Semantic Error | The received message included a semantic error. | +| Abstract Syntax Error (Falsely Constructed Message) | The received message contained IEs or IE groups in wrong order or with too many occurrences. | +| Unspecified | Sent when none of the above cause values applies but still the cause is Protocol related. | + +| Miscellaneous cause | Meaning | +|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Control Processing Overload | Control processing overload. | +| Hardware Failure | Action related to hardware failure. | +| O&M Intervention | The action is due to O&M intervention. | +| Unspecified Failure | Sent when none of the above cause values applies and the cause is not related to any of the categories Radio Network Layer, Transport Network Layer, NAS or Protocol. | + +| Service Layer cause | Meaning | +|---------------------|-------------------------------------------------------------------------------------------| +| Service Layer Cause | Used as a transparent container transporting the service layer specific cause information | + +### 9.2.2 Criticality Diagnostics + +The *Criticality Diagnostics* IE is sent by the E2 Node or the Near-RT RIC when parts of a received message have not been comprehended, or were missing, or if the message contained logical errors. When applicable, it contains information about which IEs were not comprehended or were missing. + +For further details on how to use the *Criticality Diagnostics* IE, (see clause 10). The conditions for inclusion of the *Transaction ID* IE are described in clause 10. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------------------|----------|------------------------------------|---------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Procedure Code | O | | INTEGER (0..255) | Procedure Code is to be used if Criticality Diagnostics is part of Error Indication procedure, and not within the response message of the same procedure that caused the error. | +| Triggering Message | O | | ENUMERATED (initiating message, successful outcome, unsuccessful outcome) | The Triggering Message is used only if the Criticality Diagnostics is part of Error Indication procedure. | +| Procedure Criticality | O | | ENUMERATED (reject, ignore, notify) | This Procedure Criticality is used for reporting the Criticality of the Triggering message (Procedure). | +| RIC Request ID | O | | 9.2.7 | | +| <b>Information Element Criticality Diagnostics</b> | | <i>0 .. <maxnoof Errors></i> | | | +| >IE Criticality | M | | ENUMERATED (reject, ignore, notify) | The IE Criticality is used for reporting the criticality of the triggering IE. The value 'ignore' shall not be used. | +| >IE ID | M | | INTEGER (0..65535) | The IE ID of the not understood or missing IE. | +| >Type of Error | M | | ENUMERATED (not understood, missing, ...) | | + +| Range bound | Explanation | +|---------------|------------------------------------------------------------------------------------------------------------| +| maxnoofErrors | Maximum no. of IE errors allowed to be reported with a single message. The value for maxnoofErrors is 256. | + +### 9.2.3 Message Type + +The *Message Type* IE uniquely identifies the message being sent. It is mandatory for all messages. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|----------------------------------------------------------------------------|-----------------------| +| Message Type | | | | | +| >Procedure Code | M | | INTEGER (0..255) | | +| >Type of Message | M | | CHOICE (Initiating Message, Successful Outcome, Unsuccessful Outcome, ...) | | + +### 9.2.4 Global RIC ID + +This IE is used to globally identify the Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-------------------------------|-----------------------| +| PLMN Identity | M | | 3GPP TS 38.423 clause 9.2.2.4 | | +| Near-RT RIC ID | M | | BIT STRING (SIZE(20)) | | + +### 9.2.5 Time to wait + +This IE defines the minimum allowed waiting times. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|---------------------------------------|-----------------------| +| Time to wait | M | | ENUMERATED(1s, 2s, 5s, 10s, 20s, 60s) | | + +### 9.2.6 Global E2 Node ID + +This IE is used to globally identify an E2 node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------|----------|-------|--------------------------------|----------------------------------------------------------------------------| +| CHOICE | M | | | | +| >gNB | | | | To be used when E2 Node supports gNB mode or both gNB and en-gNB modes. | +| >>Global gNB ID | M | | 3GPP TS 38.423 clause 9.2.2.1 | | +| >>Global en-gNB ID | O | | 3GPP TS 36.423 clause 9.2.112 | Required when E2 node also supports NR with en-gNB mode. | +| >>gNB-CU-UP ID | O | | 3GPP TS 37.483 clause 9.3.1.15 | Required when E2 Node supports only gNB-CU-UP functionality. | +| >>gNB-DU ID | O | | 3GPP TS 38.473 clause 9.3.1.9 | Required when E2 Node supports only gNB-DU functionality. | +| >en-gNB | | | | To be used when E2 Node supports en-gNB mode only. | +| >>Global en-gNB ID | M | | 3GPP TS 36.423 clause 9.2.112 | | +| >>en-gNB-CU-UP ID | O | | 3GPP TS 37.483 clause 9.3.1.15 | Required when E2 Node supports only gNB-CU-UP functionality. | +| >>en-gNB-DU ID | O | | 3GPP TS 38.473 clause 9.3.1.9 | Required when E2 Node supports only gNB-DU functionality. | +| >ng-eNB | | | | To be used when E2 Node supports ng-eNB mode or both ng-eNB and eNB modes. | +| >>Global ng-eNB ID | M | | 3GPP TS 38.423 clause 9.2.2.2 | | +| >>Global eNB ID | O | | 3GPP TS 36.423 clause 9.2.22 | Required when E2 Node also supports E-UTRA with eNB mode. | +| >>ng-eNB-DU ID | O | | 3GPP TS 37.473 clause 9.3.1.9 | Required when E2 node supports only ng-eNB DU functionality. | +| >eNB | | | | To be used when E2 Node supports eNB mode only. | +| >>Global eNB ID | M | | 3GPP TS 36.423 clause 9.2.22 | | + +### 9.2.7 RIC Request ID + +This information element indicates the RIC Request ID , and shall be unique for a given E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|-----------------------|-----------------------| +| RIC Requestor ID | M | | INTEGER (0.. 65535) | | +| RIC Instance ID | M | | INTEGER (0..65535) | | + +### 9.2.8 RAN Function ID + +This information element indicates the RAN Function ID, and shall be unique within a given E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------|----------|-------|-----------------------|--------------------------------------------------| +| RAN Function ID | M | | INTEGER (0..4095) | Value 0 reserved for Near-RT RIC internal usage. | + +### 9.2.9 RIC Event Trigger Definition + +This information element indicates the RIC event trigger description used by the RIC Subscription procedure. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Event Trigger Definition | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.10 RIC Action ID + +This information element indicates the Action ID number for a RIC Service Action, and shall be unique within the given RIC Request ID. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|-----------------------| +| RIC Action ID | M | | INTEGER (0..255) | | + +### 9.2.11 RIC Action Type + +This IE defines the type of RIC Service Action to be executed. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------|----------|-------|------------------------------------------|-----------------------| +| RIC Action Type | M | | ENUMERATED (Insert, Report, Policy, ...) | | + +### 9.2.12 RIC Action Definition + +This information element provides parameters to be used when executed a Report, Insert or Policy RIC Service Actions . + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Action Definition | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.13 RIC Subsequent Action + +This IE defines the subsequent action to be taken after completing a particular RIC Service Action and shall be present when RIC Action Type set to Insert. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------|---------------------------------------------------------------------------------------------------------------|-----------------------| +| RIC Subsequent Action Type | M | | ENUMERATED (Continue, Halt, ...) | | +| RIC Time to Wait | M | | ENUMERATED (1ms, 2ms, 5ms, 10ms, 20ms, 30ms, 40ms, 50ms, 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 60s, ...) | | + +### 9.2.14 RIC Indication Sequence Number (SN) + +This information element indicates the Indication Sequence Number (SN). + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------|----------|-------|-----------------------|-----------------------| +| RIC Indication SN | M | | INTEGER (0..65535) | | + +### 9.2.15 RIC Indication Type + +This IE defines the Indication Type. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|----------------------------------|-----------------------| +| RIC Indication Type | M | | ENUMERATED (Insert, Report, ...) | | + +### 9.2.16 RIC Indication message + +This information element carries the RIC indication message used for Insert and Report RIC Service Actions. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Indication message | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.17 RIC Indication header + +This information element carries the RIC indication header used for Insert and Report RIC Service Actions. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Indication header | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.18 RIC Call Process ID + +This information element carries the RIC Call Process ID used for the Insert and Control RIC Service Actions. The RIC Call Process ID shall be unique within a given RAN Function on a given E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Call Process ID | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.19 RIC Control message + +This information element carries the RIC Control message. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Control Message | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.20 RIC Control header + +This information element carries the RIC Control Header. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Control header | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.21 RIC Control Ack Request + +This IE defines whether and when the RIC CONTROL ACKNOWLEDGE message shall be sent by the E2 Node as described in the below table. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|------------------------------|-----------------------| +| RIC Control Ack Request | M | | ENUMERATED (NoAck, Ack, ...) | | + +The meaning of the different values is described in the following table. + +| RIC Service cause | Meaning | +|-------------------|-------------------------------------------------------| +| NoAck | Optional RIC Control Acknowledgement is not required. | +| Ack | Optional RIC Control Acknowledgement is required. | + +### 9.2.22 Void + +### 9.2.23 RAN Function Definition + +This information element carries the RAN Function Definition. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RAN Function Definition | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.24 RAN Function Revision + +This information element carries the RAN Function Revision. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------|----------|-------|-----------------------|-----------------------| +| RAN Function Revision | M | | INTEGER (0..4095) | | + +### 9.2.25 RIC Control Outcome + +This information element carries the RIC Control Outcome. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Control Outcome | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.26 E2 Node Component Interface Type + +This IE is used to identify an E2 node component type. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|-------|----------------------------------------------|-----------------------| +| E2 node component interface type | M | | ENUMERATED (ng, xn, e1, f1, w1, s1, x2, ...) | | + +### 9.2.27 E2 Node Component Configuration + +This IE is used to carry the E2 Node component configuration update information of a specific E2 Node component. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|-------|-----------------------|------------------------------------------------------------------------------------------------------------------| +| SEQUENCE | M | | | | +| >E2 Node Component Request Part | M | | OCTET STRING | Contents depend on component type and used to carry new or updated component configuration. See the table below. | +| >E2 Node Component Response Part | M | | OCTET STRING | Contents depend on component type and used to carry new or updated component configuration. See the table below. | + +NOTE: E2 node may generate the content of this IE using information derived from prior messages sent or received over the corresponding 3GPP Interfaces. For the E2 SETUP REQUEST message, the E2 node may derive the content of this IE from the prior messages pertaining to the Request part and the Response part of the Component Addition list in the following table and/or the Request part and the Response part of the Component Update list in the following table. + +In all cases the information is a data structure defined by the applicable 3GPP specification as specified in the following table. + +| E2 Node<br>component<br>message content | Component Addition list | | Component Update list | | +|--------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Request part | Response part | Request part | Response part | +| <b>gNB case</b> | | | | | +| >NG<br><br>(AMF Name) | NG SETUP REQUEST,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.1 | NG SETUP<br>RESPONSE,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.2 | RAN<br>CONFIGURATION<br>UPDATE,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.4<br><br>Or<br><br>AMF<br>CONFIGURATION<br>UPDATE,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.7 | RAN<br>CONFIGURATION<br>UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.5<br>Or<br><br>AMF<br>CONFIGURATION<br>UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.8 | +| >Xn<br><br>(Neighbour Global<br>NG-RAN Node ID ) | XN SETUP REQUEST,<br>3GPP TS 38.423 [20]<br>clause 9.1.3.1 | XN SETUP<br>RESPONSE,<br>3GPP TS 38.423 [20]<br>clause 9.1.3.2 | NG-RAN NODE<br>CONFIGURATION<br>UPDATE,<br>3GPP TS 38.423 [20]<br>clause 9.1.3.4 | NG-RAN NODE<br>CONFIGURATION<br>UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 38.423 [20]<br>clause 9.1.3.5 | +| >E1<br><br>(gNB-CU-UP ID) | GNB-CU-UP E1 SETUP<br>REQUEST,<br>3GPP TS 37.483 [21]<br>clause 9.2.1.4<br>Or<br><br>GNB-CU-CP E1 SETUP<br>REQUEST,<br>3GPP TS 37.483 [21]<br>clause 9.2.1.7 | GNB-CU-UP E1<br>SETUP RESPONSE,<br>3GPP TS 37.483 [21]<br>clause 9.2.1.5<br><br>Or<br><br>GNB-CU-CP E1<br>SETUP RESPONSE,<br>3GPP TS 37.483 [21]<br>clause 9.2.1.8 | GNB-CU-UP<br>CONFIGURATION<br>UPDATE,<br>3GPP TS 37.483 [21]<br>clause 9.2.1.10<br><br>Or<br><br>GNB-CU-CP<br>CONFIGURATION<br>UPDATE,<br>3GPP TS 37.483 [21]<br>clause 9.2.1.13 | GNB-CU-UP<br>CONFIGURATION<br>UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 37.483 [21]<br>clause 9.2.1.11<br>Or<br><br>GNB-CU-CP<br>CONFIGURATION<br>UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 37.483 [21]<br>clause 9.2.1.14 | +| >F1<br><br>(gNB-DU ID) | F1 SETUP REQUEST,<br>3GPP TS 38.473 [22]<br>clause 9.2.1.4 | F1 SETUP<br>RESPONSE,<br>3GPP TS 38.473 [22]<br>clause 9.2.1.5 | GNB-DU<br>CONFIGURATION<br>UPDATE,<br>3GPP TS 38.473 [22]<br>clause 9.2.1.7<br><br>Or<br><br>GNB-CU<br>CONFIGURATION<br>UPDATE,<br>3GPP TS 38.473 [22]<br>clause 9.2.1.10 | GNB-DU<br>CONFIGURATION<br>UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 38.473 [22]<br>clause 9.2.1.8<br><br>Or<br><br>GNB-CU<br>CONFIGURATION<br>UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 38.473 [22]<br>clause 9.2.1.11 | + +| E2 Node<br>component<br>message content | Component Addition list | | Component Update list | | +|----------------------------------------------|-------------------------------------------------------------------|--------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Request part | Response part | Request part | Response part | +| >X2<br><br>(Neighbour Global eNB ID) | EN-DC X2 SETUP REQUEST,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.31 | EN-DC X2 SETUP RESPONSE,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.32 | EN-DC CONFIGURATION UPDATE,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.34 | EN-DC CONFIGURATION UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.35 | +| <b>eNB case</b> | | | | | +| >NG<br><br>(AMF Name) | NG SETUP REQUEST,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.1 | NG SETUP RESPONSE,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.2 | RAN CONFIGURATION UPDATE,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.4<br><br>Or<br><br>AMF CONFIGURATION UPDATE,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.7 | RAN CONFIGURATION UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.5<br><br>Or<br><br>AMF CONFIGURATION UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 38.413 [19]<br>clause 9.2.6.8 | +| >Xn<br><br>(Neighbour Global NG-RAN Node ID) | XN SETUP REQUEST,<br>3GPP TS 38.423 [20]<br>clause 9.1.3.1 | XN SETUP RESPONSE,<br>3GPP TS 38.423 [20]<br>clause 9.1.3.2 | NG-RAN NODE CONFIGURATION UPDATE,<br>3GPP TS 38.423 [20]<br>clause 9.1.3.4 | NG-RAN NODE CONFIGURATION UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 38.423 [20]<br>clause 9.1.3.5 | +| >W1<br><br>(ng-eNB-DU ID) | W1 SETUP REQUEST,<br>3GPP TS 37.473 [23]<br>clause 9.2.1.4 | W1 SETUP RESPONSE,<br>3GPP TS 37.473 [23]<br>clause 9.2.1.5 | NG-ENB-DU CONFIGURATION UPDATE,<br>3GPP TS 37.473 [23]<br>clause 9.2.1.7<br><br>Or<br><br>NG-ENB-CU CONFIGURATION UPDATE,<br>3GPP TS 37.473 [23]<br>clause 9.2.1.10 | NG-ENB-DU CONFIGURATION UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 37.473 [23]<br>clause 9.2.1.8<br><br>Or<br><br>NG-ENB-CU CONFIGURATION UPDATE<br>ACKNOWLEDGE,<br>3GPP TS 37.473 [23]<br>clause 9.2.1.11 | + +| E2 Node component message content | Component Addition list | | Component Update list | | +|--------------------------------------------------------------------|-------------------------------------------------------------------|--------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Request part | Response part | Request part | Response part | +| >S1<br><br>(MME Name) | S1 SETUP REQUEST,<br>3GPP TS 36.413 [24]<br>clause 9.1.8.4 | S1 SETUP RESPONSE,<br>3GPP TS 36.413 [24]<br>clause 9.1.8.5 | ENB CONFIGURATION UPDATE,<br>3GPP TS 36.413 [24]<br>clause 9.1.8.7<br><br>Or<br><br>MME CONFIGURATION UPDATE,<br>3GPP TS 36.413 [24]<br>clause 9.1.8.10 | ENB CONFIGURATION UPDATE ACKNOWLEDGE,<br>3GPP TS 36.413 [24]<br>clause 9.1.8.8<br><br>Or<br><br>MME CONFIGURATION UPDATE ACKNOWLEDGE,<br>3GPP TS 36.413 [24]<br>clause 9.1.8.11 | +| >X2<br>(when neighbour is eNB)<br><br>(Neighbour Global eNB ID) | X2 SETUP REQUEST,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.3 | X2 SETUP RESPONSE,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.4 | ENB CONFIGURATION UPDATE,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.8 | ENB CONFIGURATION UPDATE ACKNOWLEDGE,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.9 | +| >X2<br>(when neighbour is en-gNB)<br><br>(Neighbour Global eNB ID) | EN-DC X2 SETUP REQUEST,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.31 | EN-DC X2 SETUP RESPONSE,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.32 | EN-DC CONFIGURATION UPDATE,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.34 | EN-DC CONFIGURATION UPDATE ACKNOWLEDGE,<br>3GPP TS 36.423 [25]<br>clause 9.1.2.35 | + +### 9.2.28 E2 Node Component Configuration Acknowledge + +This IE is used to carry the E2 Node component configuration update acknowledge of a specific E2 Node component. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------------------|-----------------------| +| Outcome | M | | ENUMERATED (success, failure,...) | | +| Cause | O | | 9.2.1 | Cause for failure. | + +### 9.2.29 Transport Layer Information + +This information element provides Near-RT RIC address and optionally port number to be used by an E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|-------------------------------|---------------------------------------------------------| +| Transport Layer Address | M | | BIT STRING (SIZE(1..160,...)) | To be passed to transport layer without interpretation. | +| Transport Layer Port | O | | BIT STRING (SIZE(16)) | To be passed to transport layer without interpretation. | + +### 9.2.30 TNL Association Usage + +This information element provides TNL association usage. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------|----------|-------|-------------------------------------------------------|----------------------------------------------------------------------------------------------------------| +| TNL Association Usage | M | | ENUMERATED (ric service, support functions, both,...) | Indicates whether E2 connection to be used for RIC services only, or E2 support functions only, or both. | + +### 9.2.31 RAN Function OID + +This information element carries the RAN Function OID and shall uniquely refer to a specific E2 Service Model (E2SM). + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|-------|-----------------------------------|----------------------------------------------------------------------------------| +| RAN Function Service Model OID | M | | PrintableString(SIZE(1..1000,..)) | Object Identifier of the specific RAN Function definition. Formatted as per OID. | + +### 9.2.32 E2 Node Component ID + +This IE is used to locally identify an E2 node component. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------|----------|-------|-------------------------------------|--------------------------| +| CHOICE <i>E2 node component interface type</i> | M | | | | +| >NG | | | | | +| >>AMF name | M | | 3GPP TS 38.413 [19] clause 9.3.3.21 | Serving AMF. | +| >Xn | | | | | +| >>Global NG-RAN Node ID | M | | 3GPP TS 38.423 [20] clause 9.2.2.3 | Neighbour gNB or ng-eNB. | +| >E1 | | | | | +| >>gNB-CU-UP ID | M | | 3GPP TS 37.483 [21] clause 9.3.1.15 | | +| >F1 | | | | | +| >>gNB-DU ID | M | | 3GPP TS 38.473 [22] clause 9.3.1.9 | | +| >W1 | | | | | +| >>ng-eNB-DU ID | M | | 3GPP TS 37.473 [23] clause 9.3.1.9 | | +| >S1 | | | | | +| >>MME name | M | | 3GPP TS 36.413 [24], clause 9.1.8.5 | Serving MME. | +| >X2 | | | | | +| >>Global eNB ID | O | | 3GPP TS 36.423 [25] clause 9.2.22 | Neighbour eNB. | +| >>Global en-gNB ID | O | | 3GPP TS 36.423 [25] clause 9.2.112 | Neighbour en-gNB. | + +### 9.2.33 Transaction ID + +The *Transaction ID* IE uniquely identifies a procedure among all ongoing parallel procedures of the same type initiated by the same protocol peer. Messages belonging to the same procedure shall use the same Transaction ID. The Transaction ID is determined by the initiating peer of a procedure. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------|-----------------------| +| Transaction ID | M | | INTEGER (0..255, ...) | | + +### 9.2.34 RIC Subscription Time + +The *RIC Subscription Time* IE is used to set the start and end time of a RIC Subscription. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------|----------|-------|---------------------------|-----------------------------------------------------------------------------------------| +| RIC Subscription time | M | | OCTET STRING<br>(SIZE(8)) | Encoded using the 64-bit timestamp format as defined in clause 6 of IETF RFC 5905 [26]. | + +### 9.2.35 RIC Action Execution Order + +This IE is used to modify the default RIC service action execution order. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------|--------------------------|--------------------------------------------------------------------------------------| +| RIC Action Execution Order | M | | INTEGER<br>(0..255, ...) | 0 used to indicate "Any-order"<br>1..255 Used to enforce a specific execution order. | + +### 9.2.36 RIC Query Header + +This information element carries the RIC Query Header. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Query Header | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.37 RIC Query Definition + +This information element carries the RIC Query Definition. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Query Definition | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.38 RIC Query Outcome + +This information element carries the RIC Query Outcome. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Query Outcome | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.39 RIC Subscription Audit Flag + +The purpose of the *RIC Subscription Audit Flag* IE is to modify to E2 Node response to a RIC SUBSCRIPTION AUDIT REQUEST message. + +| IE/Group Name | Presence | Range | IE Type and Reference | Semantics Description | +|---------------------|----------|-------|------------------------|--------------------------------------------------------------| +| Listed Records Only | O | | ENUMERATED (true, ...) | If TRUE then E2 Node shall consider the listed records only. | + +### 9.2.40 Load Measurement ID + +This information element carries the Load Measurement ID allocated by Near-RT RIC and E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-----------------------|-----------------------| +| Load measurement ID | M | | INTEGER (1..4095,...) | | + +### 9.2.41 RIC Load Information + +This information element is used to encode the load information from the E2 Node. At least one of the listed IE shall be present. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|------------------------------------------|-------------------------------------------| +| Load Status | O | | ENUMERATED (overload, not overload, ...) | | +| Load Estimate | O | | INTEGER (0..100) | Load estimation in percentage of capacity | + +### 9.2.42 RIC Service Load Information + +This information element carries the RIC Service Load Information for one or more RIC services. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------|----------|-------|-----------------------|---------------------------------------------------| +| RIC Service Report Load Information | O | | 9.2.41 | Used to carry load information on REPORT service | +| RIC Service Insert Load Information | O | | 9.2.41 | Used to carry load information on INSERT service | +| RIC Service Control Load Information | O | | 9.2.41 | Used to carry load information on CONTROL service | +| RIC Service Policy Load Information | O | | 9.2.41 | Used to carry load information on POLICY service | +| RIC Service Query Load Information | O | | 9.2.41 | Used to carry load information on QUERY service | + +### 9.2.43 RIC Load Request + +This information element requests reporting for the coreresponding RIC Load Information. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|------------------------|------------------------------------------------------------------------| +| RIC Load Request | M | | ENUMERATED (true, ...) | If TRUE then the corresponding load information reporting is requested | + +### 9.2.44 RIC Service Load Request + +This information element requests reporting for the coreresponding RIC Load Information for one or more specific RIC services. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|-------|-----------------------|------------------------------------------------------------------| +| RIC Service Report Load Request | O | | 9.2.43 | Used to request reporting of load information on REPORT service | +| RIC Service Insert Load Request | O | | 9.2.43 | Used to request reporting of load information on INSERT service | +| RIC Service Control Load Request | O | | 9.2.43 | Used to request reporting of load information on CONTROL service | +| RIC Service Policy Load Request | O | | 9.2.43 | Used to request reporting of load information on POLICY service | +| RIC Service Query Load Request | O | | 9.2.43 | Used to request reporting of load information on QUERY service | + +### 9.2.45 RIC Load Confirm + +This information element cofirms reporting for the coreresponding RIC Load Information. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|------------------------|------------------------------------------------------------------------| +| RIC Load Confirm | M | | ENUMERATED (true, ...) | If TRUE then the corresponding load information reporting is confirmed | + +### 9.2.46 RIC Service Load Confirm + +This information element confirms reporting for the coresponding RIC Load Information for one or more specific RIC services. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|-------|-----------------------|------------------------------------------------------------------| +| RIC Service Report Load Confirm | O | | 9.2.45 | Used to confirm reporting of load information on REPORT service | +| RIC Service Insert Load Confirm | O | | 9.2.45 | Used to confirm reporting of load information on INSERT service | +| RIC Service Control Load Confirm | O | | 9.2.45 | Used to confirm reporting of load information on CONTROL service | +| RIC Service Policy Load Confirm | O | | 9.2.45 | Used to confirm reporting of load information on POLICY service | +| RIC Service Query Load Confirm | O | | 9.2.45 | Used to confirm reporting of load information on QUERY service | + +### 9.2.47 RIC Assistance Header + +This information element carries the RIC Assistance Header used to indicate a specific RIC Assistance service. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Assistance Header | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.48 RIC Assistance Message + +This information element carries the RIC Assistance Message used to request a specific RIC Assistance service. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Assistance Message | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.49 RIC Assistance Update + +This information element indicates if updates are requested for a RIC Assistance service. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------|----------|-------|------------------------|---------------------------------------------------------------------| +| RIC Assistance Update | M | | ENUMERATED (true, ...) | If TRUE, then the requested RIC Assistance service is to be updated | + +### 9.2.50 RIC Assistance Update Number + +This information element indicates the maximum number of updates for a requested RIC Assistance service. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------|----------|-------|-----------------------|-----------------------| +| RIC Assistance Update Number | M | | INTEGER (0..65535) | | + +### 9.2.51 RIC Assistance Outcome + +This information element carries the RIC Assistance Outcome used to provide a specific RIC Assistance service. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| RIC Assistance Outcome | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +### 9.2.52 RIC Assistance SN + +This information element indicates the RIC Assistance SN (Sequence Number). + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------|----------|-------|-----------------------|-----------------------| +| RIC Assistance SN | M | | INTEGER (0..65535) | | + +### 9.2.53 Service Level Cause + +This information element carries the Service Level Cause message. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------| +| Service Level Cause | M | | OCTET STRING | Defined in RAN Function specific E2 Service Model, see O-RAN WG3.TS.E2SM [3]. | + +## 9.3 Message and Information Element Abstract Syntax (with ASN.1) + +### 9.3.1 General + +E2AP ASN.1 definition conforms to Recommendation ITU-T X.691 [15], Recommendation ITU-T X.680 [16] and Recommendation ITU-T X.681 [17]. + +Sub clause 9.3 presents the Abstract Syntax of the E2AP protocol with ASN.1. In case there is contradiction between the ASN.1 definition in this sub clause and the tabular format in sub clause 9.1 and 9.2, the ASN.1 shall take precedence, except for the definition of conditions for the presence of conditional elements, in which the tabular format shall take precedence. + +The ASN.1 definition specifies the structure and content of E2AP messages. E2AP messages can contain any IEs specified in the object set definitions for that message without the order or number of occurrences being restricted by ASN.1. However, for this version of the standard, a sending entity shall construct an E2AP message according to the PDU definitions module and with the following additional rules: + +- IEs shall be ordered (in an IE container) in the order they appear in object set definitions. + +- Object set definitions specify how many times IEs may appear. An IE shall appear exactly once if the presence field in an object has value "mandatory". An IE may appear at most once if the presence field in an object has value "optional" or "conditional". If in a tabular format there is multiplicity specified for an IE (i.e., an IE list) then in the corresponding ASN.1 definition the list definition is separated into two parts. The first part defines an IE container list where the list elements reside. The second part defines list elements. The IE container list appears as an IE of its own. For this version of the standard an IE container list may contain only one kind of list elements. + +NOTE: In the above "IE" means an IE in the object set with an explicit ID. If one IE needs to appear more than once in one object set, then the different occurrences will have different IE IDs. + +If an E2AP message that is not constructed as defined above is received, this shall be considered as Abstract Syntax Error, and the message shall be handled as defined for Abstract Syntax Error in clause 10. + +### 9.3.2 Usage of private message mechanism for non-standard use + +The private message mechanism for non-standard use is not supported with E2AP. + +### 9.3.3 Elementary Procedure definitions + +``` +-- ASN1START +-- ***** +-- +-- Elementary Procedure definitions +-- Derived from 3GPP 38.413 NGAP +-- ***** + +E2AP-PDU-Descriptions { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version2 (2) +e2ap(1) e2ap-PDU-Descriptions (0) } + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +-- ***** +-- +-- IE parameter types from other modules. +-- +-- ***** + +IMPORTS + Criticality, + ProcedureCode +FROM E2AP-CommonDataTypes + + E2connectionUpdate, + E2connectionUpdateAcknowledge, + E2connectionUpdateFailure, + E2nodeConfigurationUpdate, + E2nodeConfigurationUpdateAcknowledge, + E2nodeConfigurationUpdateFailure, + E2RemovalRequest, + E2RemovalResponse, + E2RemovalFailure, + E2setupFailure, + E2setupRequest, + E2setupResponse, + ErrorIndication, + ResetRequest, + ResetResponse, + RICassistanceFailure, + RICassistanceIndication, + RICassistanceHalt, +``` + +``` + + RICassistanceRequest, + RICassistanceResponse, + RICcontrolAcknowledge, + RICcontrolFailure, + RICcontrolRequest, + RICindication, + RICserviceLoadStatusRequest, + RICserviceLoadStatusResponse, + RICserviceLoadStatusFailure, + RICserviceLoadUpdate, + RICserviceQuery, + RICserviceUpdate, + RICserviceUpdateAcknowledge, + RICserviceUpdateFailure, + RICsubscriptionFailure, + RICsubscriptionRequest, + RICsubscriptionResponse, + RICsubscriptionAuditFailure, + RICsubscriptionAuditRequest, + RICsubscriptionAuditResponse, + RICsubscriptionDeleteFailure, + RICsubscriptionDeleteRequest, + RICsubscriptionDeleteResponse, + RICsubscriptionDeleteRequired, + RICsubscriptionModificationRequest, + RICsubscriptionModificationResponse, + RICsubscriptionModificationFailure, + RICsubscriptionModificationRequired, + RICsubscriptionModificationConfirm, + RICsubscriptionModificationRefuse, + RICsubscriptionStateControlRequest, + RICsubscriptionStateControlResponse, + RICsubscriptionStateControlFailure, + RICqueryRequest, + RICqueryResponse, + RICqueryFailure +FROM E2AP-PDU-Contents + + id-E2connectionUpdate, + id-E2nodeConfigurationUpdate, + id-E2removal, + id-E2setup, + id-ErrorIndication, + id-Reset, + id-RICassistance, + id-RICassistanceIndication, + id-RICassistanceHalt, + id-RICcontrol, + id-RICindication, + id-RICserviceLoadStatus, + id-RICserviceLoadUpdate, + id-RICserviceQuery, + id-RICserviceUpdate, + id-RICsubscription, + id-RICsubscriptionAudit, + id-RICsubscriptionDelete, + id-RICsubscriptionDeleteRequired, + id-RICsubscriptionModification, + id-RICsubscriptionModificationRequired, + id-RICsubscriptionStateControl, + id-RICquery +FROM E2AP-Constants; + +-- ***** +-- +-- Interface Elementary Procedure Class +-- +-- ***** + +E2AP-ELEMENTARY-PROCEDURE ::= CLASS { + &InitiatingMessage +, + +``` + +``` + + &SuccessfulOutcome OPTIONAL , + &UnsuccessfulOutcome OPTIONAL , + &procedureCode ProcedureCode UNIQUE , + &criticality Criticality DEFAULT ignore + } + + WITH SYNTAX { + INITIATING MESSAGE &InitiatingMessage + [SUCCESSFUL OUTCOME &SuccessfulOutcome] + [UNSUCCESSFUL OUTCOME &UnsuccessfulOutcome] + PROCEDURE CODE &procedureCode + [CRITICALITY &criticality] + } + +-- ***** +-- +-- Interface PDU Definition +-- +-- ***** + +E2AP-PDU ::= CHOICE { + initiatingMessage InitiatingMessage, + successfulOutcome SuccessfulOutcome, + unsuccessfulOutcome UnsuccessfulOutcome, + ... +} + +InitiatingMessage ::= SEQUENCE { + procedureCode E2AP-ELEMENTARY-PROCEDURE.&procedureCode ({E2AP-ELEMENTARY-PROCEDURES}), + criticality E2AP-ELEMENTARY-PROCEDURE.&criticality ({E2AP-ELEMENTARY- +PROCEDURES}{@procedureCode}), + value E2AP-ELEMENTARY-PROCEDURE.&InitiatingMessage ({E2AP-ELEMENTARY- +PROCEDURES}{@procedureCode}) +} + +SuccessfulOutcome ::= SEQUENCE { + procedureCode E2AP-ELEMENTARY-PROCEDURE.&procedureCode ({E2AP-ELEMENTARY-PROCEDURES}), + criticality E2AP-ELEMENTARY-PROCEDURE.&criticality ({E2AP-ELEMENTARY- +PROCEDURES}{@procedureCode}), + value E2AP-ELEMENTARY-PROCEDURE.&SuccessfulOutcome ({E2AP-ELEMENTARY- +PROCEDURES}{@procedureCode}) +} + +UnsuccessfulOutcome ::= SEQUENCE { + procedureCode E2AP-ELEMENTARY-PROCEDURE.&procedureCode ({E2AP-ELEMENTARY-PROCEDURES}), + criticality E2AP-ELEMENTARY-PROCEDURE.&criticality ({E2AP-ELEMENTARY- +PROCEDURES}{@procedureCode}), + value E2AP-ELEMENTARY-PROCEDURE.&UnsuccessfulOutcome ({E2AP-ELEMENTARY- +PROCEDURES}{@procedureCode}) +} + +-- ***** +-- +-- Interface Elementary Procedure List +-- +-- ***** + +E2AP-ELEMENTARY-PROCEDURES E2AP-ELEMENTARY-PROCEDURE ::= { + E2AP-ELEMENTARY-PROCEDURES-CLASS-1 | + E2AP-ELEMENTARY-PROCEDURES-CLASS-2, + ... +} + +E2AP-ELEMENTARY-PROCEDURES-CLASS-1 E2AP-ELEMENTARY-PROCEDURE ::= { + ricSubscription | + ricSubscriptionAudit | + ricSubscriptionDelete | + ricSubscriptionModification | + ricSubscriptionModificationRequired | + ricSubscriptionStateControl | + ricQuery | + +``` + +``` + + ricServiceUpdate + ricAssistance + ricControl + ricServiceLoadStatus + e2setup + e2nodeConfigurationUpdate + e2connectionUpdate + reset + e2removal, + ... +} + +E2AP-ELEMENTARY-PROCEDURES-CLASS-2 E2AP-ELEMENTARY-PROCEDURE ::= { + ricAssistanceIndication + ricAssistanceHalt + ricIndication + ricServiceQuery + ricServiceLoadUpdate + errorIndication + ricSubscriptionDeleteRequired, + ... +} + +-- ***** +-- +-- Interface Elementary Procedures +-- +-- ***** + +-- New for v01.01 +e2connectionUpdate E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE E2connectionUpdate + SUCCESSFUL OUTCOME E2connectionUpdateAcknowledge + UNSUCCESSFUL OUTCOME E2connectionUpdateFailure + PROCEDURE CODE id-E2connectionUpdate + CRITICALITY reject +} + +e2nodeConfigurationUpdate E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE E2nodeConfigurationUpdate + SUCCESSFUL OUTCOME E2nodeConfigurationUpdateAcknowledge + UNSUCCESSFUL OUTCOME E2nodeConfigurationUpdateFailure + PROCEDURE CODE id-E2nodeConfigurationUpdate + CRITICALITY reject +} + +-- New for v02.01 +e2removal E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE E2RemovalRequest + SUCCESSFUL OUTCOME E2RemovalResponse + UNSUCCESSFUL OUTCOME E2RemovalFailure + PROCEDURE CODE id-E2removal + CRITICALITY reject +} + +e2setup E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE E2setupRequest + SUCCESSFUL OUTCOME E2setupResponse + UNSUCCESSFUL OUTCOME E2setupFailure + PROCEDURE CODE id-E2setup + CRITICALITY reject +} + +errorIndication E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE ErrorIndication + PROCEDURE CODE id-ErrorIndication + CRITICALITY ignore +} + +reset E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE ResetRequest + +``` + +``` + + SUCCESSFUL OUTCOME ResetResponse + PROCEDURE CODE id-Reset + CRITICALITY reject + } + + ricAssistance E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICassistanceRequest + SUCCESSFUL OUTCOME RICassistanceResponse + UNSUCCESSFUL OUTCOME RICassistanceFailure + PROCEDURE CODE id-RICassistance + CRITICALITY reject + } + + ricAssistanceIndication E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICassistanceIndication + PROCEDURE CODE id-RICassistanceIndication + CRITICALITY reject + } + + ricAssistanceHalt E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICassistanceHalt + PROCEDURE CODE id-RICassistanceHalt + CRITICALITY reject + } + + ricControl E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICcontrolRequest + SUCCESSFUL OUTCOME RICcontrolAcknowledge + UNSUCCESSFUL OUTCOME RICcontrolFailure + PROCEDURE CODE id-RICcontrol + CRITICALITY reject + } + + ricIndication E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICindication + PROCEDURE CODE id-RICindication + CRITICALITY ignore + } + + ricServiceLoadStatus E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICserviceLoadStatusRequest + SUCCESSFUL OUTCOME RICserviceLoadStatusResponse + UNSUCCESSFUL OUTCOME RICserviceLoadStatusFailure + PROCEDURE CODE id-RICserviceLoadStatus + CRITICALITY ignore + } + + ricServiceLoadUpdate E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICserviceLoadUpdate + PROCEDURE CODE id-RICserviceLoadUpdate + CRITICALITY ignore + } + + ricServiceQuery E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICserviceQuery + PROCEDURE CODE id-RICserviceQuery + CRITICALITY ignore + } + + ricServiceUpdate E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICserviceUpdate + SUCCESSFUL OUTCOME RICserviceUpdateAcknowledge + UNSUCCESSFUL OUTCOME RICserviceUpdateFailure + PROCEDURE CODE id-RICserviceUpdate + CRITICALITY reject + } + + ricSubscription E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICsubscriptionRequest + SUCCESSFUL OUTCOME RICsubscriptionResponse + UNSUCCESSFUL OUTCOME RICsubscriptionFailure + } + +``` + +``` + + PROCEDURE CODE id-RICsubscription + CRITICALITY reject + } + + ricSubscriptionAudit E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICsubscriptionAuditRequest + SUCCESSFUL OUTCOME RICsubscriptionAuditResponse + UNSUCCESSFUL OUTCOME RICsubscriptionAuditFailure + PROCEDURE CODE id-RICsubscriptionAudit + CRITICALITY reject + } + + ricSubscriptionDelete E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICsubscriptionDeleteRequest + SUCCESSFUL OUTCOME RICsubscriptionDeleteResponse + UNSUCCESSFUL OUTCOME RICsubscriptionDeleteFailure + PROCEDURE CODE id-RICsubscriptionDelete + CRITICALITY reject + } + + ricSubscriptionDeleteRequired E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICsubscriptionDeleteRequired + PROCEDURE CODE id-RICsubscriptionDeleteRequired + CRITICALITY ignore + } + + ricSubscriptionModification E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICsubscriptionModificationRequest + SUCCESSFUL OUTCOME RICsubscriptionModificationResponse + UNSUCCESSFUL OUTCOME RICsubscriptionModificationFailure + PROCEDURE CODE id-RICsubscriptionModification + CRITICALITY reject + } + + ricSubscriptionModificationRequired E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICsubscriptionModificationRequired + SUCCESSFUL OUTCOME RICsubscriptionModificationConfirm + UNSUCCESSFUL OUTCOME RICsubscriptionModificationRefuse + PROCEDURE CODE id-RICsubscriptionModificationRequired + CRITICALITY reject + } + + ricSubscriptionStateControl E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICsubscriptionStateControlRequest + SUCCESSFUL OUTCOME RICsubscriptionStateControlResponse + UNSUCCESSFUL OUTCOME RICsubscriptionStateControlFailure + PROCEDURE CODE id-RICsubscriptionStateControl + CRITICALITY reject + } + + ricQuery E2AP-ELEMENTARY-PROCEDURE ::= { + INITIATING MESSAGE RICqueryRequest + SUCCESSFUL OUTCOME RICqueryResponse + UNSUCCESSFUL OUTCOME RICqueryFailure + PROCEDURE CODE id-RICquery + CRITICALITY reject + } + +END +-- ASN1STOP + +``` + +### 9.3.4 PDU definitions + +``` + +-- ASN1START +-- ***** +-- +-- PDU definitions for E2AP +-- Derived from 3GPP 38.413 (NGAP) +-- + +``` + +``` +-- ***** + +E2AP-PDU-Contents { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version2 (2) +e2ap(1) e2ap-PDU-Contents (1) } + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +-- ***** +-- +-- IE parameter types from other modules. +-- +-- ***** + +IMPORTS + Cause, + CriticalityDiagnostics, + E2nodeComponentConfiguration, + E2nodeComponentConfigurationAck, + E2nodeComponentID, + E2nodeComponentInterfaceType, + GlobalE2node-ID, + GlobalRIC-ID, + LoadMeasurementID, + RANfunctionDefinition, + RANfunctionID, + RANfunctionOID, + RANfunctionRevision, + RegistrationRequest, + ReportingPeriodicity, + RICactionDefinition, + RICactionExecutionOrder, + RICactionID, + RICactionType, + RICassistanceHeader, + RICassistanceMessage, + RICassistanceOutcome, + RICassistanceSN, + RICassistanceUpdate, + RICassistanceUpdateNumber, + RICcallProcessID, + RICcontrolAckRequest, + RICcontrolHeader, + RICcontrolMessage, + RICcontrolOutcome, + RICeventTriggerDefinition, + RICindicationHeader, + RICindicationMessage, + RICindicationSN, + RICindicationType, + RICloadConfirm, + RICloadInformation, + RICloadRequest, + RICqueryHeader, + RICqueryDefinition, + RICqueryOutcome, + RICrequestID, + RICserviceLoadConfirm, + RICserviceLoadInformation, + RICserviceLoadRequest, + RICsubsequentAction, + RICsubscriptionTime, + RICsubscriptionAuditFlag, + RICtimeToWait, + TimeToWait, + TNLinformation, + TNLusage, + TransactionID +FROM E2AP-IEs +``` + +``` + +ProtocolIE-Container{}, +ProtocolIE-ContainerList{}, +ProtocolIE-SingleContainer{}, +E2AP-PROTOCOL-IES, +E2AP-PROTOCOL-IES-PAIR +FROM E2AP-Containers + +id-Cause, +id-CriticalityDiagnostics, +id-E2connectionSetup, +id-E2connectionSetupFailed, +id-E2connectionSetupFailed-Item, +id-E2connectionFailed-Item, +id-E2connectionUpdate-Item, +id-E2connectionUpdateAdd, +id-E2connectionUpdateModify, +id-E2connectionUpdateRemove, +id-E2connectionUpdateRemove-Item, +id-E2nodeComponentConfigAddition, +id-E2nodeComponentConfigAddition-Item, +id-E2nodeComponentConfigAdditionAck, +id-E2nodeComponentConfigAdditionAck-Item, +id-E2nodeComponentConfigRemoval, +id-E2nodeComponentConfigRemoval-Item, +id-E2nodeComponentConfigRemovalAck, +id-E2nodeComponentConfigRemovalAck-Item, +id-E2nodeComponentConfigUpdate, +id-E2nodeComponentConfigUpdate-Item, +id-E2nodeComponentConfigUpdateAck, +id-E2nodeComponentConfigUpdateAck-Item, +id-E2nodeLoadMeasurementID, +id-E2nodeTNLassociationRemoval, +id-E2nodeTNLassociationRemoval-Item, +id-GlobalE2node-ID, +id-GlobalRIC-ID, +id-RANfunctionID, +id-RANfunctionID-Item, +id-RANfunctionIEcause-Item, +id-RANfunction-Item, +id-RANfunctionLoad-Item, +id-RANfunctionLoad-List, +id-RANfunctionLoadConfirm-Item, +id-RANfunctionLoadConfirm-List, +id-RANfunctionLoadRequest-Item, +id-RANfunctionLoadRequest-List, +id-RANfunctionsAccepted, +id-RANfunctionsAdded, +id-RANfunctionsDeleted, +id-RANfunctionsModified, +id-RANfunctionsRejected, +id-RANfunctionStateConfirm-Item, +id-RANfunctionStateConfirm-List, +id-RANfunctionStateControl-Item, +id-RANfunctionStateControl-List, +id-RegistrationRequest, +id-ReportingPeriodicity, +id-RIcAction-Admitted-Item, +id-RIcActionID, +id-RIcAction-NotAdmitted-Item, +id-RIcActions-Admitted, +id-RIcActions-NotAdmitted, +id-RIcAction-ToBeSetup-Item, +id-RIcActionsToBeRemovedForModification-List, +id-RIcAction-ToBeRemovedForModification-Item, +id-RIcActionsToBeModifiedForModification-List, +id-RIcAction-ToBeModifiedForModification-Item, +id-RIcActionsToBeAddedForModification-List, +id-RIcAction-ToBeAddedForModification-Item, +id-RIcActionsRemovedForModification-List, +id-RIcAction-RemovedForModification-Item, + +``` + +``` + +id-RIActionsFailedToBeRemovedForModification-List, +id-RIAction-FailedToBeRemovedForModification-Item, +id-RIActionsModifiedForModification-List, +id-RIAction-ModifiedForModification-Item, +id-RIActionsFailedToBeModifiedForModification-List, +id-RIAction-FailedToBeModifiedForModification-Item, +id-RIActionsAddedForModification-List, +id-RIAction-AddedForModification-Item, +id-RIActionsFailedToBeAddedForModification-List, +id-RIAction-FailedToBeAddedForModification-Item, +id-RIActionsRequiredToBeModified-List, +id-RIAction-RequiredToBeModified-Item, +id-RIActionsRequiredToBeRemoved-List, +id-RIAction-RequiredToBeRemoved-Item, +id-RIActionsConfirmedForModification-List, +id-RIAction-ConfirmedForModification-Item, +id-RIActionList-Item, +id-RIActionLoad-Item, +id-RIActionLoadConfirm-Item, +id-RIActionLoadRequest-Item, +id-RIActionsRefusedToBeModified-List, +id-RIAction-RefusedToBeModified-Item, +id-RIActionsConfirmedForRemoval-List, +id-RIAction-ConfirmedForRemoval-Item, +id-RIActionsRefusedToBeRemoved-List, +id-RIAction-RefusedToBeRemoved-Item, +id-RIAssistanceHeader, +id-RIAssistanceMessage, +id-RIAssistanceOutcome, +id-RIAssistanceSN, +id-RIAssistanceUpdate, +id-RIAssistanceUpdateNumber, +id-RIccallProcessID, +id-RIControlAckRequest, +id-RIControlHeader, +id-RIControlMessage, +id-RIControlOutcome, +id-RIEventTriggerDefinitionToBeModified, +id-RIIndicationHeader, +id-RIIndicationMessage, +id-RIIndicationSN, +id-RIIndicationType, +id-RIcloadMeasurementID, +id-RIcrequestID, +id-RIcserviceQuery, +id-RIcsubscriptionAuditFlag, +id-RIcsubscriptionAuditList, +id-RIcsubscriptionAudit-Item, +id-RIcsubscriptionAuditAction-Item, +id-RIcsubscriptionAuditConfirmedList, +id-RIcsubscriptionAuditMissingList, +id-RIcsubscriptionAuditUnknownList, +id-RIcsubscriptionDetails, +id-RIcsubscriptionList-Item, +id-RIcsubscriptionLoad-Item, +id-RIcsubscriptionLoadConfirm-Item, +id-RIcsubscriptionLoadRequest-Item, +id-RIcsubscriptionToBeRemoved, +id-RIcsubscription-withCause-Item, +id-RIcsubscriptionStartTime, +id-RIcsubscriptionEndTime, +id-RIcqueryHeader, +id-RIcqueryDefinition, +id-RIcqueryOutcome, +id-TimeToWait, +id-TNLInformation, +id-TransactionID, + +maxofE2nodeComponents, +maxofRANfunctionID, +maxofRIActionID, + +``` + +``` + +maxofRICrequestID, +maxofRICsubscriptions, +maxofTNLA +FROM E2AP-Constants; + +-- ***** +-- +-- MESSAGES FOR RIC FUNCTIONAL PROCEDURES +-- +-- ***** + +-- ***** +-- +-- RIC Subscription Elementary Procedure +-- +-- ***** +-- ***** +-- +-- RIC SUBSCRIPTION REQUEST +-- +-- ***** +RICsubscriptionRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionRequest-IEs}}, + ... +} + +RICsubscriptionRequest-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcrequestID CRITICALITY reject TYPE RIcrequestID PRESENCE +mandatory}}, + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory}}, + { ID id-ricsubscriptionDetails CRITICALITY reject TYPE RICsubscriptionDetails PRESENCE +mandatory}}, + ..., + { ID id-ricsubscriptionStartTime CRITICALITY reject TYPE RICsubscriptionTime PRESENCE +optional}}, + { ID id-ricsubscriptionEndTime CRITICALITY reject TYPE RICsubscriptionTime PRESENCE +optional} +} + +RICsubscriptionDetails ::= SEQUENCE { + ricEventTriggerDefinition RICeventTriggerDefinition, + ricAction-ToBeSetup-List RICactions-ToBeSetup-List, + ... +} + +RICactions-ToBeSetup-List ::= SEQUENCE (SIZE(1..maxofRICactionID)) OF ProtocolIE-SingleContainer { +{{RICaction-ToBeSetup-ItemIEs} } + +RICaction-ToBeSetup-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-ricaction-ToBeSetup-Item CRITICALITY ignore TYPE RICaction-ToBeSetup-Item PRESENCE +mandatory }}, + ... +} + +RICaction-ToBeSetup-Item ::= SEQUENCE { + ricActionID RICactionID, + ricActionType RICactionType, + ricActionDefinition RICactionDefinition OPTIONAL, + ricSubsequentAction RICsubsequentAction OPTIONAL, + ..., + ricActionExecutionOrder RICactionExecutionOrder OPTIONAL -- New in E2APv03.00 +} + +-- ***** +-- +-- RIC SUBSCRIPTION RESPONSE +-- + +``` + +``` + +-- +RICsubscriptionResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container { {RICsubscriptionResponse-IEs} }, + ... +} + +RICsubscriptionResponse-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE mandatory } | + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE mandatory } | + { ID id-RICactions-Admitted CRITICALITY reject TYPE RICAction-Admitted-List PRESENCE mandatory } | + { ID id-RICactions-NotAdmitted CRITICALITY reject TYPE RICAction-NotAdmitted-List PRESENCE optional }, + ... +} + +RICAction-Admitted-List ::= SEQUENCE (SIZE(1..maxofRICActionID)) OF ProtocolIE-SingleContainer{{RICAction-Admitted-ItemIEs}} + +RICAction-Admitted-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICaction-Admitted-Item CRITICALITY ignore TYPE RICAction-Admitted-Item PRESENCE mandatory }, + ... +} + +RICAction-Admitted-Item ::= SEQUENCE { + ricActionID RICActionID, + ... +} + +RICAction-NotAdmitted-List ::= SEQUENCE (SIZE(0..maxofRICActionID)) OF ProtocolIE-SingleContainer { {RICAction-NotAdmitted-ItemIEs} } + +RICAction-NotAdmitted-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICaction-NotAdmitted-Item CRITICALITY ignore TYPE RICAction-NotAdmitted-Item PRESENCE mandatory }, + ... +} + +RICAction-NotAdmitted-Item ::= SEQUENCE { + ricActionID RICActionID, + cause Cause, + ... +} + +-- +-- +-- RIC SUBSCRIPTION FAILURE +-- +-- +RICsubscriptionFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionFailure-IEs}}, + ... +} + +RICsubscriptionFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE mandatory } | + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE mandatory } | + { ID id-Cause CRITICALITY reject TYPE Cause PRESENCE mandatory } | + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE optional }, + ... +} + +-- + +``` + +``` +-- +-- RIC Subscription Audit Elementary Procedure +-- + + +-- +-- RIC SUBSCRIPTION AUDIT REQUEST +-- + +RICsubscriptionAuditRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionAuditRequest-IEs}}, + ... +} + +RICsubscriptionAuditRequest-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE mandatory} | + { ID id-RICsubscriptionAuditFlag CRITICALITY reject TYPE RICsubscriptionAuditFlag PRESENCE optional} | + { ID id-RICsubscriptionAuditList CRITICALITY reject TYPE RICsubscriptionAuditList PRESENCE optional}, + ... +} + +RICsubscriptionAuditList ::= SEQUENCE (SIZE(1..maxofRICsubscriptions)) OF ProtocolIE-SingleContainer { {RICsubscriptionAudit-ItemIEs} } + +RICsubscriptionAudit-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICsubscriptionAudit-Item CRITICALITY ignore TYPE RICsubscriptionAudit-Item PRESENCE mandatory }, + ... +} + +RICsubscriptionAudit-Item ::= SEQUENCE { + ricRequestID RICrequestID, + ranFunctionID RANfunctionID, + ... +} + + +-- +-- RIC SUBSCRIPTION AUDIT RESPONSE +-- + +RICsubscriptionAuditResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container{{RICsubscriptionAuditResponse-IEs}}, + ... +} + +RICsubscriptionAuditResponse-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE mandatory } | + { ID id-RICsubscriptionAuditConfirmedList CRITICALITY reject TYPE RICsubscriptionAuditActionList PRESENCE mandatory } | + { ID id-RICsubscriptionAuditUnknownList CRITICALITY reject TYPE RICsubscriptionAuditList PRESENCE optional } | + { ID id-RICsubscriptionAuditMissingList CRITICALITY reject TYPE RICsubscriptionAuditActionList PRESENCE optional }, + ... +} + +RICsubscriptionAuditActionList ::= SEQUENCE (SIZE(1..maxofRICsubscriptions)) OF ProtocolIE-SingleContainer { {RICsubscriptionAuditAction-ItemIEs} } + +RICsubscriptionAuditAction-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICsubscriptionAuditAction-Item CRITICALITY ignore TYPE RICsubscriptionAuditAction-Item PRESENCE mandatory }, + ... +} +``` + +``` + +RICsubscriptionAuditAction-Item ::= SEQUENCE { + ricRequestID RICrequestID, + ranFunctionID RANfunctionID, + ricAction-Admitted-List RICAction-Admitted-List, + ... +} + +-- ***** +-- +-- RIC SUBSCRIPTION AUDIT FAILURE +-- +-- ***** +RICsubscriptionAuditFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionAuditFailure-IEs}}, + ... +} + +RICsubscriptionAuditFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-Cause CRITICALITY reject TYPE Cause PRESENCE +mandatory }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE +optional }, + ... +} + +-- ***** +-- +-- RIC Subscription Delete Elementary Procedure +-- +-- ***** +-- ***** +-- +-- RIC SUBSCRIPTION DELETE REQUEST +-- +-- ***** +RICsubscriptionDeleteRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionDeleteRequest-IEs}}, + ... +} + +RICsubscriptionDeleteRequest-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory }, + ... +} + +-- ***** +-- +-- RIC SUBSCRIPTION DELETE RESPONSE +-- +-- ***** +RICsubscriptionDeleteResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionDeleteResponse-IEs}}, + ... +} + +RICsubscriptionDeleteResponse-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory }, + ... +} + +``` + +``` +} +-- +-- RIC SUBSCRIPTION DELETE FAILURE +-- +RICsubscriptionDeleteFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionDeleteFailure-IEs}}, + ... +} + +RICsubscriptionDeleteFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE mandatory }| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE mandatory }| + { ID id-Cause CRITICALITY ignore TYPE Cause PRESENCE mandatory }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE optional }, + ... +} + +-- +-- RIC Subscription Delete Required Elementary Procedure +-- +-- +-- RIC SUBSCRIPTION DELETE REQUIRED +-- +RICsubscriptionDeleteRequired ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionDeleteRequired-IEs}}, + ... +} + +RICsubscriptionDeleteRequired-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICsubscriptionToBeRemoved CRITICALITY ignore TYPE RICsubscription-List-withCause PRESENCE mandatory }, + ... +} + +RICsubscription-List-withCause ::= SEQUENCE (SIZE(1..maxofRICrequestID)) OF ProtocolIE-SingleContainer { {RICsubscription-withCause-ItemIEs} } + +RICsubscription-withCause-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICsubscription-withCause-Item CRITICALITY ignore TYPE RICsubscription-withCause-Item PRESENCE mandatory }, + ... +} + +RICsubscription-withCause-Item ::= SEQUENCE { + ricRequestID RICrequestID, + ranFunctionID RANfunctionID, + cause Cause, + ... +} + +-- +-- RIC Subscription Modification Elementary Procedure +-- +-- +-- RIC SUBSCRIPTION MODIFICATION REQUEST +-- +``` + +``` + +RICsubscriptionModificationRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionModificationRequest-IEs}}, + ... +} + +RICsubscriptionModificationRequest-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcrequestID CRITICALITY reject TYPE RICrequestID + PRESENCE mandatory}| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID + PRESENCE mandatory}| + { ID id-RIceventTriggerDefinitionToBeModified CRITICALITY ignore TYPE RICeventTriggerDefinition + PRESENCE optional}| + { ID id-RIcactionsToBeRemovedForModification-List CRITICALITY ignore TYPE RICactions- + ToBeRemovedForModification-List PRESENCE optional}| + { ID id-RIcactionsToBeModifiedForModification-List CRITICALITY ignore TYPE RICactions- + ToBeModifiedForModification-List PRESENCE optional}| + { ID id-RIcactionsToBeAddedForModification-List CRITICALITY ignore TYPE RICactions- + ToBeAddedForModification-List PRESENCE optional}, + ... +} + +RICactions-ToBeRemovedForModification-List ::= SEQUENCE (SIZE(0..maxofRICactionID)) OF ProtocolIE- +SingleContainer {{RICaction-ToBeRemovedForModification-ItemIEs} } + +RICaction-ToBeRemovedForModification-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcaction-ToBeRemovedForModification-Item CRITICALITY ignore TYPE RICaction- + ToBeRemovedForModification-Item PRESENCE mandatory }, + ... +} + +RICaction-ToBeRemovedForModification-Item ::= SEQUENCE { + ricActionID RICactionID, + ... +} + +RICactions-ToBeModifiedForModification-List ::= SEQUENCE (SIZE(0..maxofRICactionID)) OF ProtocolIE- +SingleContainer {{RICaction-ToBeModifiedForModification-ItemIEs} } + +RICaction-ToBeModifiedForModification-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcaction-ToBeModifiedForModification-Item CRITICALITY ignore TYPE RICaction- + ToBeModifiedForModification-Item PRESENCE mandatory }, + ... +} + +RICaction-ToBeModifiedForModification-Item ::= SEQUENCE { + ricActionID RICactionID, + ricActionDefinition RICactionDefinition OPTIONAL, + ricActionExecutionOrder RICactionExecutionOrder OPTIONAL, + ricSubsequentAction RICsubsequentAction OPTIONAL, + ... +} + +RICactions-ToBeAddedForModification-List ::= SEQUENCE (SIZE(0..maxofRICactionID)) OF ProtocolIE- +SingleContainer {{RICaction-ToBeAddedForModification-ItemIEs} } + +RICaction-ToBeAddedForModification-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcaction-ToBeAddedForModification-Item CRITICALITY ignore TYPE RICaction- + ToBeAddedForModification-Item PRESENCE mandatory }, + ... +} + +RICaction-ToBeAddedForModification-Item ::= SEQUENCE { + ricActionID RICactionID, + ricActionType RICactionType, + ricActionDefinition RICactionDefinition, + ricActionExecutionOrder RICactionExecutionOrder, + ricSubsequentAction RICsubsequentAction OPTIONAL, + ... +} +-- ***** + +``` + +``` +-- +-- RIC SUBSCRIPTION MODIFICATION RESPONSE +-- +-- ***** +RICsubscriptionModificationResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionModificationResponse-IEs}}, + ... +} + +RICsubscriptionModificationResponse-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIRequestID CRITICALITY reject TYPE RICrequestID + PRESENCE mandatory}}| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID + PRESENCE mandatory}}| + { ID id-RIActionsRemovedForModification-List CRITICALITY ignore TYPE RICactions- + RemovedForModification-List PRESENCE optional}}| + { ID id-RIActionsFailedToBeRemovedForModification-List CRITICALITY ignore TYPE RICactions- + FailedToBeRemovedForModification-List PRESENCE optional}}| + { ID id-RIActionsModifiedForModification-List CRITICALITY ignore TYPE RICactions- + ModifiedForModification-List PRESENCE optional}}| + { ID id-RIActionsFailedToBeModifiedForModification-List CRITICALITY ignore TYPE RICactions- + FailedToBeModifiedForModification-List PRESENCE optional}}| + { ID id-RIActionsAddedForModification-List CRITICALITY ignore TYPE RICactions- + AddedForModification-List PRESENCE optional}}| + { ID id-RIActionsFailedToBeAddedForModification-List CRITICALITY ignore TYPE RICactions- + FailedToBeAddedForModification-List PRESENCE optional}, + ... +} + +RICactions-RemovedForModification-List ::= SEQUENCE (SIZE(0..maxofRICactionID)) OF ProtocolIE- +SingleContainer {{RICaction-RemovedForModification-ItemIEs} } + +RICaction-RemovedForModification-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIAction-RemovedForModification-Item CRITICALITY ignore TYPE RICaction- + RemovedForModification-Item PRESENCE mandatory }, + ... +} + +RICaction-RemovedForModification-Item ::= SEQUENCE { + ricActionID RICactionID, + ... +} + +RICactions-FailedToBeRemovedForModification-List ::= SEQUENCE (SIZE(0..maxofRICactionID)) OF ProtocolIE- +SingleContainer {{RICaction-FailedToBeRemovedForModification-ItemIEs} } + +RICaction-FailedToBeRemovedForModification-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIAction-FailedToBeRemovedForModification-Item CRITICALITY ignore TYPE RICaction- + FailedToBeRemovedForModification-Item PRESENCE mandatory }, + ... +} + +RICaction-FailedToBeRemovedForModification-Item ::= SEQUENCE { + ricActionID RICactionID, + cause Cause, + ... +} + +RICactions-ModifiedForModification-List ::= SEQUENCE (SIZE(0..maxofRICactionID)) OF ProtocolIE- +SingleContainer {{RICaction-ModifiedForModification-ItemIEs} } + +RICaction-ModifiedForModification-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIAction-ModifiedForModification-Item CRITICALITY ignore TYPE RICaction- + ModifiedForModification-Item PRESENCE mandatory }, + ... +} + +RICaction-ModifiedForModification-Item ::= SEQUENCE { + ricActionID RICactionID, + ... +} +``` + +``` +RICActions-FailedToBeModifiedForModification-List ::= SEQUENCE (SIZE(0..maxofRICActionID)) OF ProtocolIE- +SingleContainer {{RICAction-FailedToBeModifiedForModification-ItemIEs} } +``` + +``` +RICAction-FailedToBeModifiedForModification-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIAction-FailedToBeModifiedForModification-Item CRITICALITY ignore TYPE RICAction- +FailedToBeModifiedForModification-Item PRESENCE mandatory }, + ... +} +``` + +``` +RICAction-FailedToBeModifiedForModification-Item ::= SEQUENCE { + ricActionID RICActionID, + cause Cause, + ... +} +``` + +``` +RICActions-AddedForModification-List ::= SEQUENCE (SIZE(0..maxofRICActionID)) OF ProtocolIE- +SingleContainer {{RICAction-AddedForModification-ItemIEs} } +``` + +``` +RICAction-AddedForModification-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIAction-AddedForModification-Item CRITICALITY ignore TYPE RICAction-AddedForModification- +Item PRESENCE mandatory }, + ... +} +``` + +``` +RICAction-AddedForModification-Item ::= SEQUENCE { + ricActionID RICActionID, + ... +} +``` + +``` +RICActions-FailedToBeAddedForModification-List ::= SEQUENCE (SIZE(0..maxofRICActionID)) OF ProtocolIE- +SingleContainer {{RICAction-FailedToBeAddedForModification-ItemIEs} } +``` + +``` +RICAction-FailedToBeAddedForModification-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIAction-FailedToBeAddedForModification-Item CRITICALITY ignore TYPE RICAction- +FailedToBeAddedForModification-Item PRESENCE mandatory }, + ... +} +``` + +``` +RICAction-FailedToBeAddedForModification-Item ::= SEQUENCE { + ricActionID RICActionID, + cause Cause, + ... +} +``` + +``` +-- ***** +``` + +``` +-- +``` + +``` +-- RIC SUBSCRIPTION MODIFICATION FAILURE +``` + +``` +-- +``` + +``` +-- ***** +``` + +``` +RICSubscriptionModificationFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICSubscriptionModificationFailure-IEs}}, + ... +} +``` + +``` +RICSubscriptionModificationFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIRequestID CRITICALITY reject TYPE RIRequestID PRESENCE +mandatory}| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory}| + { ID id-Cause CRITICALITY reject TYPE Cause PRESENCE mandatory}| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE +optional}, + ... +} +``` + +``` +-- ***** +``` + +``` +-- +``` + +``` +-- RIC Subscription Modification Required Elementary Procedure +``` + +``` +-- +``` + +``` +-- ***** +``` + +``` +-- ***** +``` + +``` +-- +-- RIC SUBSCRIPTION MODIFICATION REQUIRED +-- +-- +RICsubscriptionModificationRequired ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionModificationRequired-IEs}}, + ... +} + +RICsubscriptionModificationRequired-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID + PRESENCE mandatory}| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID + PRESENCE mandatory}| + { ID id-RICactionsRequiredToBeModified-List CRITICALITY ignore TYPE RICactions-RequiredToBeModified-List PRESENCE optional}| + { ID id-RICactionsRequiredToBeRemoved-List CRITICALITY ignore TYPE RICactions-RequiredToBeRemoved-List PRESENCE optional}, + ... +} + +RICActions-RequiredToBeModified-List ::= SEQUENCE (SIZE(0..maxofRICactionID)) OF ProtocolIE-SingleContainer {{RICaction-RequiredToBeModified-ItemIEs} } + +RICaction-RequiredToBeModified-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICaction-RequiredToBeModified-Item CRITICALITY ignore TYPE RICaction-RequiredToBeModified-Item PRESENCE mandatory }, + ... +} + +RICaction-RequiredToBeModified-Item ::= SEQUENCE { + ricActionID RICactionID, + ricTimeToWait RICtimeToWait, + ... +} + +RICActions-RequiredToBeRemoved-List ::= SEQUENCE (SIZE(0..maxofRICactionID)) OF ProtocolIE-SingleContainer {{RICaction-RequiredToBeRemoved-ItemIEs} } + +RICaction-RequiredToBeRemoved-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICaction-RequiredToBeRemoved-Item CRITICALITY ignore TYPE RICaction-RequiredToBeRemoved-Item PRESENCE mandatory }, + ... +} + +RICaction-RequiredToBeRemoved-Item ::= SEQUENCE { + ricActionID RICactionID, + cause Cause, + ... +} + +-- +-- +-- RIC SUBSCRIPTION MODIFICATION CONFIRM +-- +-- +RICsubscriptionModificationConfirm ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionModificationConfirm-IEs}}, + ... +} + +RICsubscriptionModificationConfirm-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID + PRESENCE mandatory}| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID + PRESENCE mandatory}| + { ID id-RICactionsConfirmedForModification-List CRITICALITY ignore TYPE RICactions-ConfirmedForModification-List PRESENCE optional}| + { ID id-RICactionsRefusedToBeModified-List CRITICALITY ignore TYPE RICactions-RefusedToBeModified-List PRESENCE optional}| + +``` + +``` + + { ID id-RIActionsConfirmedForRemoval-List CRITICALITY ignore TYPE RIActions- +ConfirmedForRemoval-List PRESENCE optional}| + { ID id-RIActionsRefusedToBeRemoved-List CRITICALITY ignore TYPE RIActions- +RefusedToBeRemoved-List PRESENCE optional}, + ... + } + +RIActions-ConfirmedForModification-List ::= SEQUENCE (SIZE(0..maxofRICActionID)) OF ProtocolIE- +SingleContainer {{RICAction-ConfirmedForModification-ItemIEs} } + +RICAction-ConfirmedForModification-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIAction-ConfirmedForModification-Item CRITICALITY ignore TYPE RICAction- +ConfirmedForModification-Item PRESENCE mandatory }, + ... +} + +RICAction-ConfirmedForModification-Item ::= SEQUENCE { + ricActionID RICActionID, + ... +} + +RIActions-RefusedToBeModified-List ::= SEQUENCE (SIZE(0..maxofRICActionID)) OF ProtocolIE-SingleContainer +{{RICAction-RefusedToBeModified-ItemIEs} } + +RICAction-RefusedToBeModified-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIAction-RefusedToBeModified-Item CRITICALITY ignore TYPE RICAction- +RefusedToBeModified-Item PRESENCE mandatory }, + ... +} + +RICAction-RefusedToBeModified-Item ::= SEQUENCE { + ricActionID RICActionID, + cause Cause, + ... +} + +RIActions-ConfirmedForRemoval-List ::= SEQUENCE (SIZE(0..maxofRICActionID)) OF ProtocolIE-SingleContainer +{{RICAction-ConfirmedForRemoval-ItemIEs} } + +RICAction-ConfirmedForRemoval-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIAction-ConfirmedForRemoval-Item CRITICALITY ignore TYPE RICAction- +ConfirmedForRemoval-Item PRESENCE mandatory }, + ... +} + +RICAction-ConfirmedForRemoval-Item ::= SEQUENCE { + ricActionID RICActionID, + ... +} + +RIActions-RefusedToBeRemoved-List ::= SEQUENCE (SIZE(0..maxofRICActionID)) OF ProtocolIE-SingleContainer +{{RICAction-RefusedToBeRemoved-ItemIEs} } + +RICAction-RefusedToBeRemoved-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RIAction-RefusedToBeRemoved-Item CRITICALITY ignore TYPE RICAction- +RefusedToBeRemoved-Item PRESENCE mandatory }, + ... +} + +RICAction-RefusedToBeRemoved-Item ::= SEQUENCE { + ricActionID RICActionID, + cause Cause, + ... +} + +-- ***** +-- +-- RIC SUBSCRIPTION MODIFICATION REFUSE +-- +-- ***** +RICsubscriptionModificationRefuse ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionModificationRefuse-IEs}}, + +``` + +``` + +... +} + +RICsubscriptionModificationRefuse-IES E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory}| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory}| + { ID id-Cause CRITICALITY reject TYPE Cause PRESENCE mandatory}| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE +optional}, + ... +} + + +-- +-- RIC Subscription State Control Elementary Procedure +-- + + +-- +-- RIC SUBSCRIPTION STATE CONTROL REQUEST +-- + +RICsubscriptionStateControlRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionStateControlRequest- +IES}}, + ... +} + +RICsubscriptionStateControlRequest-IES E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-RANfunctionStateControl-List CRITICALITY reject TYPE RANfunctionStateControl-List PRESENCE +mandatory }, + ... +} + +RANfunctionStateControl-List ::= SEQUENCE (SIZE(1..maxofRANfunctionID)) OF ProtocolIE-SingleContainer { +{RANfunctionStateControl-ItemIEs} } + +RANfunctionStateControl-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RANfunctionStateControl-Item CRITICALITY reject TYPE RANfunctionStateControl-Item +PRESENCE mandatory }, + ... +} + +RANfunctionStateControl-Item ::= SEQUENCE { + ranFunctionID RANfunctionID, + ricSubscriptionToBeSuspended-list RICsubscriptionToBeSuspended-List OPTIONAL, + ricSubscriptionToBeResumed-list RICsubscriptionToBeResumed-List OPTIONAL, + ... +} + +RICsubscriptionToBeSuspended-List ::= SEQUENCE (SIZE(1..maxofRICrequestID)) OF ProtocolIE-SingleContainer { +{RICsubscriptionList-ItemIEs} } + +RICsubscriptionToBeResumed-List ::= SEQUENCE (SIZE(1..maxofRICrequestID)) OF ProtocolIE-SingleContainer { +{RICsubscriptionList-ItemIEs} } + +RICsubscriptionList-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICsubscriptionList-Item CRITICALITY reject TYPE RICsubscriptionList-Item PRESENCE +mandatory }, + ... +} + +RICsubscriptionList-Item ::= SEQUENCE { + ricRequestID RICrequestID, + ricAction-list RICaction-List OPTIONAL, + ... +} + +``` + +``` + +RICAction-List ::= SEQUENCE (SIZE(1..maxofRICActionID)) OF ProtocolIE-SingleContainer { {RICAction-ItemIEs} } + +RICAction-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICActionList-Item CRITICALITY reject TYPE RICActionList-Item PRESENCE mandatory }, + ... +} + +RICActionList-Item ::= SEQUENCE { + ricActionID RICActionID, + ... +} + +-- ***** +-- +-- RIC SUBSCRIPTION STATE CONTROL RESPONSE +-- +-- ***** +RICsubscriptionStateControlResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionStateControlResponse-IEs}}, + ... +} + +RICsubscriptionStateControlResponse-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcrequestID CRITICALITY reject TYPE RIcrequestID PRESENCE mandatory }| + { ID id-RANfunctionStateConfirm-List CRITICALITY reject TYPE RANfunctionStateConfirm-List PRESENCE mandatory }, + ... +} + +RANfunctionStateConfirm-List ::= SEQUENCE (SIZE(1..maxofRANfunctionID)) OF ProtocolIE-SingleContainer { {RANfunctionStateConfirm-ItemIEs} } + +RANfunctionStateConfirm-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RANfunctionStateConfirm-Item CRITICALITY reject TYPE RANfunctionStateConfirm-Item PRESENCE mandatory }, + ... +} + +RANfunctionStateConfirm-Item ::= SEQUENCE { + ranFunctionID RANfunctionID, + ricSubscriptionSuspended-list RICsubscriptionSuspended-List OPTIONAL, + ricSubscriptionResumed-list RICsubscriptionResumed-List OPTIONAL, + ... +} + +RICsubscriptionSuspended-List ::= SEQUENCE (SIZE(1..maxofRIcrequestID)) OF ProtocolIE-SingleContainer { {RICsubscriptionList-ItemIEs} } + +RICsubscriptionResumed-List ::= SEQUENCE (SIZE(1..maxofRIcrequestID)) OF ProtocolIE-SingleContainer { {RICsubscriptionList-ItemIEs} } + +-- ***** +-- +-- RIC SUBSCRIPTION STATE CONTROL FAILURE +-- +-- ***** +RICsubscriptionStateControlFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICsubscriptionStateControlFailure-IEs}}, + ... +} + +RICsubscriptionStateControlFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcrequestID CRITICALITY reject TYPE RIcrequestID PRESENCE mandatory }| + +``` + +``` + + { ID id-Cause CRITICALITY reject TYPE Cause + PRESENCE mandatory }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics + PRESENCE optional }, + ... +} + +-- ***** +-- +-- RIC Assistance Elementary Procedure +-- +-- ***** +-- ***** +-- +-- RIC ASSISTANCE REQUEST +-- +-- ***** +RICAssistanceRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICAssistanceRequest-IEs}}, + ... +} + +RICAssistanceRequest-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIRequestID CRITICALITY reject TYPE RIRequestID PRESENCE + mandatory }| + { ID id-RIAssistanceHeader CRITICALITY reject TYPE RIAssistanceHeader PRESENCE + mandatory }| + { ID id-RIAssistanceMessage CRITICALITY reject TYPE RIAssistanceMessage PRESENCE + mandatory }| + { ID id-RIAssistanceUpdate CRITICALITY reject TYPE RIAssistanceUpdate PRESENCE + optional }| + { ID id-RIAssistanceUpdateNumber CRITICALITY reject TYPE RIAssistanceUpdateNumber PRESENCE + optional }, + ... +} + +-- ***** +-- +-- RIC ASSISTANCE RESPONSE +-- +-- ***** +RICAssistanceResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICAssistanceResponse-IEs}}, + ... +} + +RICAssistanceResponse-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIRequestID CRITICALITY reject TYPE RIRequestID PRESENCE + mandatory }| + { ID id-RIAssistanceHeader CRITICALITY reject TYPE RIAssistanceHeader PRESENCE + mandatory }| + { ID id-RIAssistanceOutcome CRITICALITY reject TYPE RIAssistanceOutcome PRESENCE + mandatory }, + ... +} + +-- ***** +-- +-- RIC ASSISTANCE FAILURE +-- +-- ***** +RICAssistanceFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICAssistanceFailure-IEs}}, + ... +} + +RICAssistanceFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIRequestID CRITICALITY reject TYPE RIRequestID PRESENCE + mandatory }| + { ID id-Cause CRITICALITY ignore TYPE Cause PRESENCE + mandatory }| + +``` + +``` + + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE +optional }, + ... + } + +-- +-- +-- RIC Assistance Indication Elementary Procedure +-- +-- +-- +-- +-- RIC ASSISTANCE INDICATION +-- +-- +RICassistanceIndication ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICassistanceIndication-IEs}}, + ... +} + +RICassistanceIndication-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-RICassistanceSN CRITICALITY reject TYPE RICassistanceSN PRESENCE +mandatory }| + { ID id-RICassistanceHeader CRITICALITY reject TYPE RICassistanceHeader PRESENCE +mandatory }| + { ID id-RICassistanceOutcome CRITICALITY reject TYPE RICassistanceOutcome PRESENCE +mandatory }, + ... +} + +-- +-- +-- RIC Assistance Halt Elementary Procedure +-- +-- +-- +-- +-- RIC ASSISTANCE HALT +-- +-- +RICassistanceHalt ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICassistanceHalt-IEs}}, + ... +} + +RICassistanceHalt-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }, + ... +} + +-- +-- +-- RIC Indication Elementary Procedure +-- +-- +-- +-- +-- RIC INDICATION +-- +-- +RICindication ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICindication-IEs}}, + ... +} + +RICindication-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + +``` + +``` + + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory }| + { ID id-RIActionID CRITICALITY reject TYPE RICActionID PRESENCE +mandatory }| + { ID id-RIIndicationSN CRITICALITY reject TYPE RICindicationSN PRESENCE +optional }| + { ID id-RIIndicationType CRITICALITY reject TYPE RICindicationType PRESENCE +mandatory }| + { ID id-RIIndicationHeader CRITICALITY reject TYPE RICindicationHeader PRESENCE +mandatory }| + { ID id-RIIndicationMessage CRITICALITY reject TYPE RICindicationMessage PRESENCE +mandatory }| + { ID id-RIccallProcessID CRITICALITY reject TYPE RICcallProcessID PRESENCE +optional }, + ... + } + +-- ***** +-- +-- RIC Control Elementary Procedure +-- +-- ***** +-- ***** +-- +-- RIC CONTROL REQUEST +-- +-- ***** +RICcontrolRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICcontrolRequest-IEs}}, + ... +} + +RICcontrolRequest-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory }| + { ID id-RIccallProcessID CRITICALITY reject TYPE RICcallProcessID PRESENCE +optional }| + { ID id-RIcontrolHeader CRITICALITY reject TYPE RICcontrolHeader PRESENCE +mandatory }| + { ID id-RIcontrolMessage CRITICALITY reject TYPE RICcontrolMessage PRESENCE +mandatory }| + { ID id-RIcontrolAckRequest CRITICALITY reject TYPE RICcontrolAckRequest PRESENCE +optional }, + ... +} + +-- ***** +-- +-- RIC CONTROL ACKNOWLEDGE +-- +-- ***** +RICcontrolAcknowledge ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICcontrolAcknowledge-IEs}}, + ... +} + +RICcontrolAcknowledge-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory }| + { ID id-RIccallProcessID CRITICALITY reject TYPE RICcallProcessID PRESENCE +optional }| + { ID id-RIcontrolOutcome CRITICALITY reject TYPE RICcontrolOutcome PRESENCE +optional }, + ... +} + +-- ***** +-- +-- RIC CONTROL FAILURE + +``` + +``` +-- +-- +RICcontrolFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICcontrolFailure-IEs}}, + ... +} + +RICcontrolFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory }| + { ID id-RICcallProcessID CRITICALITY reject TYPE RICcallProcessID PRESENCE +optional }| + { ID id-Cause CRITICALITY ignore TYPE Cause PRESENCE +mandatory }| + { ID id-RICcontrolOutcome CRITICALITY reject TYPE RICcontrolOutcome PRESENCE +optional }, + ... + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE +optional } +} + +-- +-- +-- RIC QUERY Elementary Procedure +-- +-- +-- +-- +-- RIC QUERY REQUEST +-- +-- +RICqueryRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICqueryRequest-IEs}}, + ... +} + +RICqueryRequest-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory }| + { ID id-RICqueryHeader CRITICALITY reject TYPE RICqueryHeader PRESENCE +mandatory }| + { ID id-RICqueryDefinition CRITICALITY reject TYPE RICqueryDefinition PRESENCE +mandatory }, + ... +} + +-- +-- +-- RIC QUERY RESPONSE +-- +-- +RICqueryResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICqueryResponse-IEs}}, + ... +} + +RICqueryResponse-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory }| + { ID id-RICqueryOutcome CRITICALITY reject TYPE RICqueryOutcome PRESENCE +mandatory }, + ... +} +-- +-- +``` + +``` +-- RIC QUERY FAILURE +-- +RICQueryFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICQueryFailure-IEs}}, + ... +} + +RICQueryFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +mandatory }| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +mandatory }| + { ID id-Cause CRITICALITY ignore TYPE Cause PRESENCE +mandatory }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE +optional }, + ... +} + +-- +-- RIC Service Load Status Elementary Procedure +-- +-- +-- RIC SERVICE LOAD STATUS REQUEST +-- +RICServiceLoadStatusRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICServiceLoadStatusRequest-IEs}}, + ... +} + +RICServiceLoadStatusRequest-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICloadMeasurementID CRITICALITY reject TYPE LoadMeasurementID PRESENCE +mandatory }| + { ID id-E2nodeLoadMeasurementID CRITICALITY ignore TYPE LoadMeasurementID PRESENCE +conditional}| + { ID id-RegistrationRequest CRITICALITY ignore TYPE RegistrationRequest PRESENCE +mandatory }| + { ID id-RANfunctionLoadRequest-List CRITICALITY reject TYPE RANfunctionLoadRequest-List PRESENCE +conditional}| + { ID id-ReportingPeriodicity CRITICALITY ignore TYPE ReportingPeriodicity PRESENCE +optional }, + ... +} + +RANfunctionLoadRequest-List ::= SEQUENCE (SIZE(1..maxofRANfunctionID)) OF ProtocolIE-SingleContainer { {RANfunctionLoadRequest-ItemIEs} } + +RANfunctionLoadRequest-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RANfunctionLoadRequest-Item CRITICALITY reject TYPE RANfunctionLoadRequest-Item PRESENCE +mandatory }, + ... +} + +RANfunctionLoadRequest-Item ::= SEQUENCE { + ranFunctionID RANfunctionID, + ranFunctionLoadRequest RICloadRequest OPTIONAL, + ricServiceLoadRequest RICserviceLoadRequest OPTIONAL, + ricSubscriptionLoadRequest-list RICsubscriptionLoadRequest-List OPTIONAL, + ... +} + +RICsubscriptionLoadRequest-List ::= SEQUENCE (SIZE(1..maxofRICrequestID)) OF ProtocolIE-SingleContainer { {RICsubscriptionLoadRequest-ItemIEs} } + +RICsubscriptionLoadRequest-ItemIEs E2AP-PROTOCOL-IES ::= { +``` + +``` + + { ID id-RICsubscriptionLoadRequest-Item CRITICALITY reject TYPE RICsubscriptionLoadRequest-ItemIE + PRESENCE mandatory }, + ... +} + +RICsubscriptionLoadRequest-ItemIE ::= SEQUENCE { + ricRequestID RICrequestID, + ricSubscriptionLoadRequest RICloadRequest OPTIONAL, + ricActionLoadRequest-list RICactionLoadRequest-List OPTIONAL, + ... +} + +RICactionLoadRequest-List ::= SEQUENCE (SIZE(1..maxofRICactionID)) OF ProtocolIE-SingleContainer { +{RICactionLoadRequest-ItemIEs} } + +RICactionLoadRequest-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICactionLoadRequest-Item CRITICALITY reject TYPE RICactionLoadRequest-Item + PRESENCE mandatory }, + ... +} + +RICactionLoadRequest-Item ::= SEQUENCE { + ricActionID RICactionID, + ricActionLoadRequest RICloadRequest, + ... +} + +-- RIC SERVICE LOAD STATUS RESPONSE + +RICserviceLoadStatusResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICserviceLoadStatusResponse-IEs}}, + ... +} + +RICserviceLoadStatusResponse-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RICloadMeasurementID CRITICALITY reject TYPE LoadMeasurementID PRESENCE + mandatory }| + { ID id-E2nodeLoadMeasurementID CRITICALITY ignore TYPE LoadMeasurementID PRESENCE + mandatory }| + { ID id-RANfunctionLoadConfirm-List CRITICALITY reject TYPE RANfunctionLoadConfirm-List PRESENCE + conditional }, + ... +} + +RANfunctionLoadConfirm-List ::= SEQUENCE (SIZE(1..maxofRANfunctionID)) OF ProtocolIE-SingleContainer { +{RANfunctionLoadConfirm-ItemIEs} } + +RANfunctionLoadConfirm-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RANfunctionLoadConfirm-Item CRITICALITY reject TYPE RANfunctionLoadConfirm-Item PRESENCE + mandatory }, + ... +} + +RANfunctionLoadConfirm-Item ::= SEQUENCE { + ranFunctionID RANfunctionID, + ranFunctionLoadConfirm RICloadConfirm OPTIONAL, + ricServiceLoadConfirm RICserviceLoadConfirm OPTIONAL, + ricSubscriptionLoadConfirm-list RICsubscriptionLoadConfirm-List OPTIONAL, + ... +} + +RICsubscriptionLoadConfirm-List ::= SEQUENCE (SIZE(1..maxofRICrequestID)) OF ProtocolIE-SingleContainer { +{RICsubscriptionLoadConfirm-ItemIEs} } + +RICsubscriptionLoadConfirm-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICsubscriptionLoadConfirm-Item CRITICALITY reject TYPE RICsubscriptionLoadConfirm-ItemIE + PRESENCE mandatory }, + ... +} + +``` + +``` + +} + +RICsubscriptionLoadConfirm-ItemIE ::= SEQUENCE { + ricRequestID RICRequestID, + ricSubscriptionLoadConfirm RICloadConfirm OPTIONAL, + ricActionLoadConfirm-list RICActionLoadConfirm-List OPTIONAL, + ... +} + +RICActionLoadConfirm-List ::= SEQUENCE (SIZE (1..maxofRICActionID)) OF ProtocolIE-SingleContainer { + {RICActionLoadConfirm-ItemIEs} } + +RICActionLoadConfirm-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICActionLoadConfirm-Item CRITICALITY reject TYPE RICActionLoadConfirm-Item PRESENCE mandatory }, + ... +} + +RICActionLoadConfirm-Item ::= SEQUENCE { + ricActionID RICActionID, + ricActionLoadConfirm RICloadConfirm, + ... +} + +-- +-- RIC SERVICE LOAD STATUS FAILURE +-- +RICserviceLoadStatusFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICserviceLoadStatusFailure-IEs}}, + ... +} + +RICserviceLoadStatusFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcloadMeasurementID CRITICALITY reject TYPE LoadMeasurementID PRESENCE mandatory }| + { ID id-E2nodeLoadMeasurementID CRITICALITY ignore TYPE LoadMeasurementID PRESENCE mandatory }| + { ID id-Cause CRITICALITY ignore TYPE Cause PRESENCE mandatory }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE optional }, + ... +} + +-- +-- RIC Service Load Update Elementary Procedure +-- +-- +-- RIC SERVICE LOAD UPDATE +-- +RICserviceLoadUpdate ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICserviceLoadUpdate-IEs}}, + ... +} + +RICserviceLoadUpdate-IEs E2AP-PROTOCOL-IES ::= { + { ID id-RIcloadMeasurementID CRITICALITY reject TYPE LoadMeasurementID PRESENCE mandatory }| + { ID id-E2nodeLoadMeasurementID CRITICALITY ignore TYPE LoadMeasurementID PRESENCE mandatory }| + { ID id-RANfunctionLoad-List CRITICALITY reject TYPE RANfunctionLoad-List PRESENCE mandatory }, + ... +} + +``` + +``` + +RANfunctionLoad-List ::= SEQUENCE (SIZE(1..maxofRANfunctionID)) OF ProtocolIE-SingleContainer { +{RANfunctionLoad-ItemIEs} } + +RANfunctionLoad-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RANfunctionLoad-Item CRITICALITY reject TYPE RANfunctionLoad-Item PRESENCE +mandatory }, + ... +} + +RANfunctionLoad-Item ::= SEQUENCE { + ranFunctionID RANfunctionID, + ranFunctionLoadInformation RICloadInformation OPTIONAL, + ricServiceLoadInformation RICserviceLoadInformation OPTIONAL, + ricSubscriptionLoad-list RICsubscriptionLoad-List OPTIONAL, + ... +} + +RICsubscriptionLoad-List ::= SEQUENCE (SIZE(1..maxofRICrequestID)) OF ProtocolIE-SingleContainer { +{RICsubscriptionLoad-ItemIEs} } + +RICsubscriptionLoad-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICsubscriptionLoad-Item CRITICALITY reject TYPE RICsubscriptionLoad-ItemIE PRESENCE +mandatory }, + ... +} + +RICsubscriptionLoad-ItemIE ::= SEQUENCE { + ricRequestID RICrequestID, + ricSubscriptionLoadInformation RICloadInformation OPTIONAL, + ricActionLoad-list RICactionLoad-List OPTIONAL, + ... +} + +RICactionLoad-List ::= SEQUENCE (SIZE(1..maxofRICactionID)) OF ProtocolIE-SingleContainer { +{RICactionLoad-ItemIEs} } + +RICactionLoad-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RICactionLoad-Item CRITICALITY reject TYPE RICactionLoad-Item PRESENCE +mandatory }, + ... +} + +RICactionLoad-Item ::= SEQUENCE { + ricActionID RICactionID, + ricActionLoadInformation RICloadInformation, + ... +} + +-- ***** +-- +-- MESSAGES FOR GLOBAL PROCEDURES +-- +-- ***** + +-- ***** +-- +-- Error Indication Elementary Procedure +-- +-- ***** +-- ***** +-- +-- ERROR INDICATION +-- +-- ***** +ErrorIndication ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{ErrorIndication-IEs}}, + ... +} + +ErrorIndication-IEs E2AP-PROTOCOL-IES ::= { + +``` + +``` + + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE +optional }| + { ID id-RIcrequestID CRITICALITY reject TYPE RICrequestID PRESENCE +optional }| + { ID id-RANfunctionID CRITICALITY reject TYPE RANfunctionID PRESENCE +optional }| + { ID id-Cause CRITICALITY ignore TYPE Cause PRESENCE +optional }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE +optional }, + ... + } + +-- ***** +-- +-- E2 Setup Elementary Procedure +-- +-- ***** +-- ***** +-- +-- E2 SETUP REQUEST +-- +-- ***** + +E2setupRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container { {E2setupRequestIEs} }, + ... +} + +E2setupRequestIEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE + PRESENCE mandatory }| + { ID id-GlobalE2node-ID CRITICALITY reject TYPE GlobalE2node-ID PRESENCE +mandatory }| + { ID id-RANfunctionsAdded CRITICALITY reject TYPE RANfunctions-List PRESENCE +mandatory }| + { ID id-E2nodeComponentConfigAddition CRITICALITY reject TYPE E2nodeComponentConfigAddition-List + PRESENCE mandatory }, + ... +} + +-- ***** +-- +-- E2 SETUP RESPONSE +-- +-- ***** + +E2setupResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container { {E2setupResponseIEs} }, + ... +} + +E2setupResponseIEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE + PRESENCE mandatory }| + { ID id-GlobalRIC-ID CRITICALITY reject TYPE GlobalRIC-ID PRESENCE + PRESENCE mandatory }| + { ID id-RANfunctionsAccepted CRITICALITY reject TYPE RANfunctionsID-List PRESENCE + PRESENCE optional }| + { ID id-RANfunctionsRejected CRITICALITY reject TYPE RANfunctionsIDcause-List PRESENCE + PRESENCE optional }| + { ID id-E2nodeComponentConfigAdditionAck CRITICALITY reject TYPE E2nodeComponentConfigAdditionAck-List + PRESENCE mandatory }, + ... +} + +-- ***** +-- +-- E2 SETUP FAILURE +-- +-- ***** + +``` + +``` + +E2setupFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container { {E2setupFailureIEs} }, + ... +} + +E2setupFailureIEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE +mandatory }| + { ID id-Cause CRITICALITY ignore TYPE Cause PRESENCE +mandatory }| + { ID id-TimeToWait CRITICALITY ignore TYPE TimeToWait PRESENCE +optional }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE +optional }| + { ID id-TNLinformation CRITICALITY ignore TYPE TNLinformation PRESENCE +optional }, + ... +} + +-- +-- +-- E2 Connection Update Elementary Procedure +-- +-- +-- +-- +-- E2 CONNECTION UPDATE +-- +-- +E2connectionUpdate ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{E2connectionUpdate-IEs}}, + ... +} + +E2connectionUpdate-IEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE +mandatory }| + { ID id-E2connectionUpdateAdd CRITICALITY reject TYPE E2connectionUpdate-List PRESENCE +optional }| + { ID id-E2connectionUpdateRemove CRITICALITY reject TYPE E2connectionUpdateRemove-List PRESENCE +optional }| + { ID id-E2connectionUpdateModify CRITICALITY reject TYPE E2connectionUpdate-List PRESENCE +optional }, + ... +} + +E2connectionUpdate-List ::= SEQUENCE (SIZE(1..maxofTNLA)) OF ProtocolIE-SingleContainer { +{E2connectionUpdate-ItemIEs} } + +E2connectionUpdate-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-E2connectionUpdate-Item CRITICALITY ignore TYPE E2connectionUpdate-Item PRESENCE +mandatory }, + ... +} + +E2connectionUpdate-Item ::= SEQUENCE { + tnlInformation TNLinformation, + tnlUsage TNLusage, + ... +} + +E2connectionUpdateRemove-List ::= SEQUENCE (SIZE(1..maxofTNLA)) OF ProtocolIE-SingleContainer { +{E2connectionUpdateRemove-ItemIEs} } + +E2connectionUpdateRemove-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-E2connectionUpdateRemove-Item CRITICALITY ignore TYPE E2connectionUpdateRemove-Item +PRESENCE mandatory }, + ... +} + +``` + +``` + +E2connectionUpdateRemove-Item ::= SEQUENCE { + tnlInformation TNLinformation, + ... +} + +-- ***** +-- +-- E2 CONNECTION UPDATE ACKNOWLEDGE +-- +-- ***** +E2connectionUpdateAcknowledge ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{E2connectionUpdateAck-IEs}}, + ... +} + +E2connectionUpdateAck-IEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE +mandatory }| + { ID id-E2connectionSetup CRITICALITY reject TYPE E2connectionUpdate-List PRESENCE +optional }| + { ID id-E2connectionSetupFailed CRITICALITY reject TYPE E2connectionSetupFailed-List PRESENCE +optional }, + ... +} + +E2connectionSetupFailed-List ::= SEQUENCE (SIZE(1..maxofTNLA)) OF ProtocolIE-SingleContainer { +{E2connectionSetupFailed-ItemIEs} } + +E2connectionSetupFailed-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-E2connectionSetupFailed-Item CRITICALITY ignore TYPE E2connectionSetupFailed-Item +PRESENCE mandatory }, + ... +} + +E2connectionSetupFailed-Item ::= SEQUENCE { + tnlInformation TNLinformation, + cause Cause, + ... +} + +-- ***** +-- +-- E2 CONNECTION UPDATE FAILURE +-- +-- ***** +E2connectionUpdateFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{E2connectionUpdateFailure-IEs}}, + ... +} + +E2connectionUpdateFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID +PRESENCE mandatory }| + { ID id-Cause CRITICALITY reject TYPE Cause +PRESENCE optional }| + { ID id-TimeToWait CRITICALITY ignore TYPE TimeToWait +PRESENCE optional }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics +PRESENCE optional }, + ... +} + +-- ***** +-- +-- E2 Node Configuration Update Elementary Procedure +-- +-- ***** +-- + +``` + +``` +-- E2 NODE CONFIGURATION UPDATE +-- +-- ***** +E2nodeConfigurationUpdate ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{E2nodeConfigurationUpdate-IEs}}, + ... +} + +E2nodeConfigurationUpdate-IEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID + PRESENCE mandatory }| + { ID id-GlobalE2node-ID CRITICALITY reject TYPE GlobalE2node-ID + PRESENCE optional }| + { ID id-E2nodeComponentConfigAddition CRITICALITY reject TYPE E2nodeComponentConfigAddition-List + PRESENCE optional }| + { ID id-E2nodeComponentConfigUpdate CRITICALITY reject TYPE E2nodeComponentConfigUpdate-List + PRESENCE optional }| + { ID id-E2nodeComponentConfigRemoval CRITICALITY reject TYPE E2nodeComponentConfigRemoval-List + PRESENCE optional }| + { ID id-E2nodeTNLassociationRemoval CRITICALITY reject TYPE E2nodeTNLassociationRemoval-List + PRESENCE optional }, + ... +} + +E2nodeComponentConfigAddition-List ::= SEQUENCE (SIZE(1..maxofE2nodeComponents)) OF ProtocolIE- +SingleContainer { {E2nodeComponentConfigAddition-ItemIEs} } + +E2nodeComponentConfigAddition-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-E2nodeComponentConfigAddition-Item CRITICALITY reject TYPE E2nodeComponentConfigAddition- + Item PRESENCE mandatory }, + ... +} + +E2nodeComponentConfigAddition-Item ::= SEQUENCE { + e2nodeComponentInterfaceType E2nodeComponentInterfaceType, + e2nodeComponentID E2nodeComponentID, + e2nodeComponentConfiguration E2nodeComponentConfiguration, + ... +} + +E2nodeComponentConfigUpdate-List ::= SEQUENCE (SIZE(1..maxofE2nodeComponents)) OF ProtocolIE- +SingleContainer { {E2nodeComponentConfigUpdate-ItemIEs} } + +E2nodeComponentConfigUpdate-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-E2nodeComponentConfigUpdate-Item CRITICALITY reject TYPE E2nodeComponentConfigUpdate-Item + PRESENCE mandatory }, + ... +} + +E2nodeComponentConfigUpdate-Item ::= SEQUENCE { + e2nodeComponentInterfaceType E2nodeComponentInterfaceType, + e2nodeComponentID E2nodeComponentID, + e2nodeComponentConfiguration E2nodeComponentConfiguration, + ... +} + +E2nodeComponentConfigRemoval-List ::= SEQUENCE (SIZE(1..maxofE2nodeComponents)) OF ProtocolIE- +SingleContainer { {E2nodeComponentConfigRemoval-ItemIEs} } + +E2nodeComponentConfigRemoval-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-E2nodeComponentConfigRemoval-Item CRITICALITY reject TYPE E2nodeComponentConfigRemoval-Item + PRESENCE mandatory }, + ... +} + +E2nodeComponentConfigRemoval-Item ::= SEQUENCE { + e2nodeComponentInterfaceType E2nodeComponentInterfaceType, + e2nodeComponentID E2nodeComponentID, + ... +} +``` + +``` + +E2nodeTNLassociationRemoval-List ::= SEQUENCE (SIZE(1..maxofTNLA)) OF ProtocolIE-SingleContainer { +{E2nodeTNLassociationRemoval-ItemIEs} } + +E2nodeTNLassociationRemoval-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-E2nodeTNLassociationRemoval-Item CRITICALITY reject TYPE E2nodeTNLassociationRemoval-Item + PRESENCE mandatory }, + ... +} + +E2nodeTNLassociationRemoval-Item ::= SEQUENCE { + tnlInformation TNLinformation, + tnlInformationRIC TNLinformation, + ... +} + +-- ***** +-- +-- E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE +-- +-- ***** +E2nodeConfigurationUpdateAcknowledge ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{E2nodeConfigurationUpdateAcknowledge-IEs}}, + ... +} + +E2nodeConfigurationUpdateAcknowledge-IEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID + PRESENCE mandatory }| + { ID id-E2nodeComponentConfigAdditionAck CRITICALITY reject TYPE +E2nodeComponentConfigAdditionAck-List PRESENCE optional }| + { ID id-E2nodeComponentConfigUpdateAck CRITICALITY reject TYPE +E2nodeComponentConfigUpdateAck-List PRESENCE optional }| + { ID id-E2nodeComponentConfigRemovalAck CRITICALITY reject TYPE +E2nodeComponentConfigRemovalAck-List PRESENCE optional }, + ... +} + +E2nodeComponentConfigAdditionAck-List ::= SEQUENCE (SIZE(1..maxofE2nodeComponents)) OF ProtocolIE- +SingleContainer { {E2nodeComponentConfigAdditionAck-ItemIEs} } + +E2nodeComponentConfigAdditionAck-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-E2nodeComponentConfigAdditionAck-Item CRITICALITY reject TYPE +E2nodeComponentConfigAdditionAck-Item PRESENCE mandatory }, + ... +} + +E2nodeComponentConfigAdditionAck-Item ::= SEQUENCE { + e2nodeComponentInterfaceType E2nodeComponentInterfaceType, + e2nodeComponentID E2nodeComponentID, + e2nodeComponentConfigurationAck E2nodeComponentConfigurationAck, + ... +} + +E2nodeComponentConfigUpdateAck-List ::= SEQUENCE (SIZE(1..maxofE2nodeComponents)) OF ProtocolIE- +SingleContainer { {E2nodeComponentConfigUpdateAck-ItemIEs} } + +E2nodeComponentConfigUpdateAck-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-E2nodeComponentConfigUpdateAck-Item CRITICALITY reject TYPE +E2nodeComponentConfigUpdateAck-Item PRESENCE mandatory }, + ... +} + +E2nodeComponentConfigUpdateAck-Item ::= SEQUENCE { + e2nodeComponentInterfaceType E2nodeComponentInterfaceType, + e2nodeComponentID E2nodeComponentID, + e2nodeComponentConfigurationAck E2nodeComponentConfigurationAck, + ... +} + +E2nodeComponentConfigRemovalAck-List ::= SEQUENCE (SIZE(1..maxofE2nodeComponents)) OF ProtocolIE- +SingleContainer { {E2nodeComponentConfigRemovalAck-ItemIEs} } + +``` + +``` + +E2nodeComponentConfigRemovalAck-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-E2nodeComponentConfigRemovalAck-Item CRITICALITY reject TYPE E2nodeComponentConfigRemovalAck-Item PRESENCE mandatory }, + ... +} + +E2nodeComponentConfigRemovalAck-Item ::= SEQUENCE { + e2nodeComponentInterfaceType E2nodeComponentInterfaceType, + e2nodeComponentID E2nodeComponentID, + e2nodeComponentConfigurationAck E2nodeComponentConfigurationAck, + ... +} + + +-- +-- E2 NODE CONFIGURATION UPDATE FAILURE +-- + +E2nodeConfigurationUpdateFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{E2nodeConfigurationUpdateFailure-IEs}}, + ... +} + +E2nodeConfigurationUpdateFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID + PRESENCE mandatory } | + { ID id-Cause CRITICALITY ignore TYPE Cause + PRESENCE mandatory } | + { ID id-TimeToWait CRITICALITY ignore TYPE TimeToWait + PRESENCE optional } | + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics + PRESENCE optional }, + ... +} + + +-- +-- Reset Elementary Procedure +-- + + +-- +-- RESET REQUEST +-- + + +ResetRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{ResetRequestIEs}}, + ... +} + +ResetRequestIEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE mandatory } | + { ID id-Cause CRITICALITY ignore TYPE Cause PRESENCE mandatory }, + ... +} + + +-- +-- RESET RESPONSE +-- + + +ResetResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{ResetResponseIEs}}, + ... +} + +``` + +``` + +ResetResponseIEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE +mandatory }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE +optional }, + ... +} + +-- ***** +-- +-- RIC Service Update Elementary Procedure +-- +-- ***** +-- ***** +-- +-- RIC SERVICE UPDATE +-- +-- ***** +RICserviceUpdate ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICserviceUpdate-IEs}}, + ... +} + +RICserviceUpdate-IEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE +mandatory }| + { ID id-RANfunctionsAdded CRITICALITY reject TYPE RANfunctions-List PRESENCE +optional }| + { ID id-RANfunctionsModified CRITICALITY reject TYPE RANfunctions-List PRESENCE +optional }| + { ID id-RANfunctionsDeleted CRITICALITY reject TYPE RANfunctionsID-List PRESENCE +optional }, + ... +} + +RANfunctions-List ::= SEQUENCE (SIZE(1..maxofRANfunctionID)) OF ProtocolIE-SingleContainer { {RANfunction- +ItemIEs} } + +RANfunction-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RANfunction-Item CRITICALITY ignore TYPE RANfunction-Item PRESENCE +mandatory }, + ... +} + +RANfunction-Item ::= SEQUENCE { + ranFunctionID RANfunctionID, + ranFunctionDefinition RANfunctionDefinition, + ranFunctionRevision RANfunctionRevision, + ranFunctionOID RANfunctionOID, + ... +} + +RANfunctionsID-List ::= SEQUENCE (SIZE(1..maxofRANfunctionID)) OF ProtocolIE- +SingleContainer{{RANfunctionID-ItemIEs}} + +RANfunctionID-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RANfunctionID-Item CRITICALITY ignore TYPE RANfunctionID-Item PRESENCE +mandatory }, + ... +} + +RANfunctionID-Item ::= SEQUENCE { + ranFunctionID RANfunctionID, + ranFunctionRevision RANfunctionRevision, + ... +} + +-- ***** +-- + +``` + +``` + +-- RIC SERVICE UPDATE ACKNOWLEDGE +-- +-- ***** +RICserviceUpdateAcknowledge ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICserviceUpdateAcknowledge-IEs}}, + ... +} + +RICserviceUpdateAcknowledge-IEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE +mandatory }| + { ID id-RANfunctionsAccepted CRITICALITY reject TYPE RANfunctionsID-List PRESENCE +optional }| + { ID id-RANfunctionsRejected CRITICALITY reject TYPE RANfunctionsIDcause-List PRESENCE +optional }, + ... +} + +RANfunctionsIDcause-List ::= SEQUENCE (SIZE(1..maxofRANfunctionID)) OF ProtocolIE-SingleContainer { +{RANfunctionIDcause-ItemIEs} } + +RANfunctionIDcause-ItemIEs E2AP-PROTOCOL-IES ::= { + { ID id-RANfunctionIEcause-Item CRITICALITY ignore TYPE RANfunctionIDcause-Item PRESENCE +mandatory }, + ... +} + +RANfunctionIDcause-Item ::= SEQUENCE { + ranFunctionID RANfunctionID, + cause Cause, + ... +} + +-- ***** +-- +-- RIC SERVICE UPDATE FAILURE +-- +-- ***** +RICserviceUpdateFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICserviceUpdateFailure-IEs}}, + ... +} + +RICserviceUpdateFailure-IEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE +mandatory }| + { ID id-Cause CRITICALITY reject TYPE Cause PRESENCE +mandatory }| + { ID id-TimeToWait CRITICALITY ignore TYPE TimeToWait PRESENCE +optional }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE +optional }, + ... +} + +-- ***** +-- +-- RIC Service Query Elementary Procedure +-- +-- ***** +-- +-- RIC SERVICE QUERY +-- +-- ***** +RICserviceQuery ::= SEQUENCE { + protocolIEs ProtocolIE-Container {{RICserviceQuery-IEs}}, + ... +} + +``` + +``` + +RICServiceQuery-IEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE + mandatory }| + { ID id-RANfunctionsAccepted CRITICALITY reject TYPE RANfunctionsID-List PRESENCE + optional }, + ... +} + +-- ***** +-- +-- E2 Removal Elementary Procedure +-- +-- ***** +-- ***** +-- +-- E2 REMOVAL REQUEST +-- +-- ***** + +E2RemovalRequest ::= SEQUENCE { + protocolIEs ProtocolIE-Container { {E2RemovalRequestIEs} }, + ... +} + +E2RemovalRequestIEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE + mandatory }, + ... +} + +-- ***** +-- +-- E2 REMOVAL RESPONSE +-- +-- ***** + +E2RemovalResponse ::= SEQUENCE { + protocolIEs ProtocolIE-Container { {E2RemovalResponseIEs} }, + ... +} + +E2RemovalResponseIEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID + PRESENCE mandatory }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE + optional }, + ... +} + +-- ***** +-- +-- E2 REMOVAL FAILURE +-- +-- ***** + +E2RemovalFailure ::= SEQUENCE { + protocolIEs ProtocolIE-Container { {E2RemovalFailureIEs} }, + ... +} + +E2RemovalFailureIEs E2AP-PROTOCOL-IES ::= { + { ID id-TransactionID CRITICALITY reject TYPE TransactionID PRESENCE + mandatory }| + { ID id-Cause CRITICALITY ignore TYPE Cause PRESENCE + mandatory }| + { ID id-CriticalityDiagnostics CRITICALITY ignore TYPE CriticalityDiagnostics PRESENCE + optional }, + ... +} + +``` + +``` +END +-- ASN1STOP +``` + +### 9.3.5 Information Element definitions + +``` +-- ASN1START +-- ***** +-- E2AP +-- Information Element Definitions +-- +-- ***** + +E2AP-IEs { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version2 (2) +e2ap(1) e2ap-IEs (2)} + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +IMPORTS + Criticality, + Presence, + ProcedureCode, + ProtocolIE-ID, + TriggeringMessage +FROM E2AP-CommonDataTypes + + maxnoofErrors, + maxProtocolIEs +FROM E2AP-Constants; + +-- A + +-- ***** +-- [New for E2AP v02.00] copied from 3GPP 38.413 (NGAP) IEs +-- ***** +AMFName ::= PrintableString (SIZE(1..150, ...)) + +-- B +-- C +Cause ::= CHOICE { + ricRequest CauseRICrequest, + ricService CauseRICservice, + e2Node CauseE2node, + transport CauseTransport, + protocol CauseProtocol, + misc CauseMisc, + ..., + serviceLayer CauseServiceLayer +} + +CauseE2node ::= ENUMERATED { + e2node-component-unknown, + ... +} + +CauseMisc ::= ENUMERATED { + control-processing-overload, + hardware-failure, + om-intervention, + unspecified, + ... +} + +CauseProtocol ::= ENUMERATED { + transfer-syntax-error, + abstract-syntax-error-reject, + abstract-syntax-error-ignore-and-notify, + message-not-compatible-with-receiver-state, +``` + +``` + + semantic-error, + abstract-syntax-error-falsely-constructed-message, + unspecified, + ... +} + +CauseRICrequest ::= ENUMERATED { + ran-function-id-invalid, + action-not-supported, + excessive-actions, + duplicate-action, + duplicate-event-trigger, + function-resource-limit, + request-id-unknown, + inconsistent-action-subsequent-action-sequence, + control-message-invalid, + ric-call-process-id-invalid, + control-timer-expired, + control-failed-to-execute, + system-not-ready, + unspecified, + ... , + ric-subscription-end-time-expired, + ric-subscription-end-time-invalid, + duplicate-ric-request-id, + eventTriggerNotSupported, + requested-information-unavailable, + invalid-information-request +} + +CauseRICservice ::= ENUMERATED{ + ran-function-not-supported, + excessive-functions, + ric-resource-limit, + ... +} + +CauseServiceLayer ::= SEQUENCE { + serviceLayerCause ServiceLayerCause, + ... +} + +CauseTransport ::= ENUMERATED { + unspecified, + transport-resource-unavailable, + ... +} + +-- ***** +-- copied from 3GPP 38.413 (NGAP) IEs +-- note: ie-Extensions removed +-- ***** +CriticalityDiagnostics ::= SEQUENCE { + procedureCode ProcedureCode OPTIONAL, + triggeringMessage TriggeringMessage OPTIONAL, + procedureCriticality Criticality OPTIONAL, + ricRequestorID RICrequestID OPTIONAL, + iEsCriticalityDiagnostics CriticalityDiagnostics-IE-List OPTIONAL, + ... +} + +CriticalityDiagnostics-IE-List ::= SEQUENCE (SIZE(1..maxnoofErrors)) OF CriticalityDiagnostics-IE-Item + +CriticalityDiagnostics-IE-Item ::= SEQUENCE { + iECriticality Criticality, + iE-ID ProtocolIE-ID, + typeOfError TypeOfError, + ... +} + +-- D + +``` + +``` +-- E + +-- Following IE used to carry 3GPP defined SETUP and RAN Configuration messages defined in FlAP, E1AP, +XnAP, etc. +E2nodeComponentConfiguration ::= SEQUENCE{ + e2nodeComponentRequestPart OCTET STRING, + e2nodeComponentResponsePart OCTET STRING, + ... +} + +E2nodeComponentConfigurationAck ::= SEQUENCE{ + updateOutcome ENUMERATED {success, failure, ...}, + failureCause Cause OPTIONAL, + ... +} + +E2nodeComponentInterfaceType ::= ENUMERATED {ng, xn, e1, f1, w1, s1, x2,...} + +E2nodeComponentID ::= CHOICE{ + e2nodeComponentInterfaceTypeNG E2nodeComponentInterfaceNG, + e2nodeComponentInterfaceTypeXn E2nodeComponentInterfaceXn, + e2nodeComponentInterfaceTypeE1 E2nodeComponentInterfaceE1, + e2nodeComponentInterfaceTypeF1 E2nodeComponentInterfaceF1, + e2nodeComponentInterfaceTypeW1 E2nodeComponentInterfaceW1, + e2nodeComponentInterfaceTypeS1 E2nodeComponentInterfaceS1, + e2nodeComponentInterfaceTypeX2 E2nodeComponentInterfaceX2, + ... +} + +E2nodeComponentInterfaceE1 ::= SEQUENCE{ + gNB-CU-UP-ID GNB-CU-UP-ID, + ... +} + +E2nodeComponentInterfaceF1 ::= SEQUENCE{ + gNB-DU-ID GNB-DU-ID, + ... +} + +E2nodeComponentInterfaceNG ::= SEQUENCE{ + amf-name AMFName, + ... +} + +E2nodeComponentInterfaceS1 ::= SEQUENCE{ + mme-name MMName, + ... +} + +E2nodeComponentInterfaceX2 ::= SEQUENCE{ + global-eNB-ID GlobalENB-ID OPTIONAL, + global-en-gNB-ID GlobalenGNB-ID OPTIONAL, + ... +} + +E2nodeComponentInterfaceXn ::= SEQUENCE{ + global-NG-RAN-Node-ID GlobalNG-RANNode-ID, + ... +} + +E2nodeComponentInterfaceW1 ::= SEQUENCE{ + ng-eNB-DU-ID NGENB-DU-ID, + ... +} + +-- ***** +-- copied from 3GPP 36.423 (X2AP) IEs +-- note: ie-Extensions removed +-- ***** +ENB-ID ::= CHOICE { + macro-eNB-ID BIT STRING (SIZE (20)), +``` + +``` + + home-eNB-ID BIT STRING (SIZE (28)), + ... , + short-Macro-eNB-ID BIT STRING (SIZE(18)), + long-Macro-eNB-ID BIT STRING (SIZE(21)) +} + +-- copied from 3GPP 38.423 (XnAP) IEs +-- note: choice-extension removed + +ENB-ID-Choice ::= CHOICE { + enb-ID-macro BIT STRING (SIZE(20)), + enb-ID-shortmacro BIT STRING (SIZE(18)), + enb-ID-longmacro BIT STRING (SIZE(21)), + ... +} + + +-- copied from 3GPP 36.423 (X2AP) IEs +-- note: ie-Extensions removed +-- Note: to avoid duplicate names with XnAP, GNB-ID renamed ENGNB-ID, GlobalGNB-ID renamed GlobalenGNB-ID + +ENGNB-ID ::= CHOICE { + gNB-ID BIT STRING (SIZE (22..32)), + ... +} + +-- F +-- G +GlobaleE2node-ID ::= CHOICE{ + gNB GlobaleE2node-gNB-ID, + en-gNB GlobaleE2node-en-gNB-ID, + ng-eNB GlobaleE2node-ng-eNB-ID, + eNB GlobaleE2node-eNB-ID, + ... +} + +GlobaleE2node-en-gNB-ID ::= SEQUENCE{ + global-en-gNB-ID GlobalenGNB-ID, + en-gNB-CU-UP-ID GNB-CU-UP-ID OPTIONAL, + en-gNB-DU-ID GNB-DU-ID OPTIONAL, + ... +} + +GlobaleE2node-eNB-ID ::= SEQUENCE{ + global-eNB-ID GlobalENB-ID, + ... +} + +GlobaleE2node-gNB-ID ::= SEQUENCE{ + global-gNB-ID GlobalgNB-ID, + global-en-gNB-ID GlobalenGNB-ID OPTIONAL, + gNB-CU-UP-ID GNB-CU-UP-ID OPTIONAL, + gNB-DU-ID GNB-DU-ID OPTIONAL, + ... +} + +GlobaleE2node-ng-eNB-ID ::= SEQUENCE{ + global-ng-eNB-ID GlobalngeNB-ID, + global-eNB-ID GlobalENB-ID OPTIONAL, + ngENB-DU-ID NGENB-DU-ID OPTIONAL, + ... +} + + +-- copied from 3GPP 36.423 (X2AP) IEs +-- note: ie-Extensions removed + +GlobalENB-ID ::= SEQUENCE { + pLMN-Identity PLMN-Identity, + eNB-ID ENB-ID, + ... +} + + +-- copied from 3GPP 36.423 (X2AP) IEs + +``` + +``` +-- Note: to avoid duplicate names with XnAP, GNB-ID renamed ENGNB-ID, GlobalGNB-ID renamed GlobalenGNB-ID +-- +GlobalenGNB-ID ::= SEQUENCE { + pLMN-Identity PLMN-Identity, + gNB-ID ENGNB-ID, + ... +} +-- +-- copied from 3GPP 38.423 (XnAP) IEs +-- note: choice-extension removed +-- +GlobalgNB-ID ::= SEQUENCE { + plmn-id PLMN-Identity, + gnb-id GNB-ID-Choice, + ... +} + +-- +-- copied from 3GPP 38.423 (XnAP) IEs +-- note: choice-extension removed +-- +GlobalngeNB-ID ::= SEQUENCE { + plmn-id PLMN-Identity, + enb-id ENB-ID-Choice, + ... +} + +-- +-- [NEW for E2AP v02.00] copied from 3GPP 38.423 (XnAP) IEs +-- Note: extension field removed +-- + +GlobalNG-RANNode-ID ::= CHOICE { + gNB GlobalgNB-ID, + ng-eNB GlobalngeNB-ID, + ... +} + +GlobalRIC-ID ::= SEQUENCE { + pLMN-Identity PLMN-Identity, + ric-ID BIT STRING (SIZE (20)), + ... +} + +-- +-- copied from 3GPP 37.483 (E1AP) IEs +-- +GNB-CU-UP-ID::= INTEGER (0..68719476735) + +-- +-- copied from 3GPP 38.473 (F1AP) IEs +-- +GNB-DU-ID::= INTEGER (0..68719476735) + +-- +-- copied from 3GPP 38.423 (XnAP) IEs +-- note: choice-extension removed +-- +GNB-ID-Choice ::= CHOICE { + gnb-ID BIT STRING (SIZE (22..32)), + ... +} +-- H +-- I +-- J +-- K +-- L + +ListedRecordsOnly ::= ENUMERATED {true, ...} +``` + +``` + +LoadMeasurementID ::= INTEGER(1..4095,...) + +-- M + +-- ***** +-- [New for E2AP v02.00] copied from 3GPP 36.413 (S1AP) IEs +-- ***** +MMEName ::= PrintableString (SIZE (1..150,...)) + +-- N + +-- ***** +-- copied from 3GPP 37.473 (W1AP) IEs +-- ***** +NGENB-DU-ID ::= INTEGER (0..68719476735) + +-- O +-- P +-- ***** +-- copied from 3GPP 36.423 (X2AP) IEs +-- ***** +PLMN-Identity ::= OCTET STRING (SIZE(3)) + +-- Q +-- R +-- ***** +-- Following IE defined in E2SM +-- ***** +RANfunctionDefinition ::= OCTET STRING + +RANfunctionID ::= INTEGER (0..4095) + +RANfunctionOID ::= PrintableString(SIZE(1..1000,...)) + +RANfunctionRevision ::= INTEGER (0..4095) + +RegistrationRequest ::= ENUMERATED{start, stop, add, ...} + +ReportingPeriodicity ::= ENUMERATED{ms500, ms1000, ms2000, ms5000, ms10000, ...} + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICActionDefinition ::= OCTET STRING + +-- new in E2AP-v03.00 +RICActionExecutionOrder ::= INTEGER (0..255, ...) + +RICActionID ::= INTEGER (0..255) + +RICActionType ::= ENUMERATED{ + report, + insert, + policy, + ... +} +-- ***** +-- Following IE defined in E2SM +-- ***** +RICAssistanceHeader ::= OCTET STRING + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICAssistanceMessage ::= OCTET STRING + +-- ***** +-- Following IE defined in E2SM +-- ***** + +``` + +``` + +RICassistanceOutcome ::= OCTET STRING + +RICassistanceSN ::= INTEGER (0..65535) + +RICassistanceUpdate ::= ENUMERATED{ + true, + ... +} + +RICassistanceUpdateNumber ::= INTEGER (0..65535) + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICcallProcessID ::= OCTET STRING + +RICcontrolAckRequest ::= ENUMERATED{ + noAck, + ack, + ... +} + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICcontrolHeader ::= OCTET STRING + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICcontrolMessage ::= OCTET STRING + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICcontrolOutcome ::= OCTET STRING + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICeventTriggerDefinition ::= OCTET STRING + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICindicationHeader ::= OCTET STRING + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICindicationMessage ::= OCTET STRING + +RICindicationSN ::= INTEGER (0..65535) + +RICindicationType ::= ENUMERATED{ + report, + insert, + ... +} + +RICloadConfirm ::= ENUMERATED{ + true, + ... +} + +RICloadInformation ::= SEQUENCE{ + loadStatus ENUMERATED{overload, notoverload, ...} OPTIONAL, + loadEstimate INTEGER (0..100) OPTIONAL, + ... +} + +``` + +``` + +RICloadRequest ::= ENUMERATED{ + true, + ... +} + +RICrequestID ::= SEQUENCE { + ricRequestorID INTEGER (0..65535), + ricInstanceID INTEGER (0..65535), + ... +} + +RICserviceLoadConfirm ::= SEQUENCE{ + ricServiceReportLoadConfirm RICloadConfirm OPTIONAL, + ricServiceInsertLoadConfirm RICloadConfirm OPTIONAL, + ricServiceControlLoadConfirm RICloadConfirm OPTIONAL, + ricServicePolicyLoadConfirm RICloadConfirm OPTIONAL, + ricServiceQueryLoadConfirm RICloadConfirm OPTIONAL, + ... +} + +RICserviceLoadInformation ::= SEQUENCE{ + ricServiceReportLoadInformation RICloadInformation OPTIONAL, + ricServiceInsertLoadInformation RICloadInformation OPTIONAL, + ricServiceControlLoadInformation RICloadInformation OPTIONAL, + ricServicePolicyLoadInformation RICloadInformation OPTIONAL, + ricServiceQueryLoadInformation RICloadInformation OPTIONAL, + ... +} + +RICserviceLoadRequest ::= SEQUENCE{ + ricServiceReportLoadRequest RICloadRequest OPTIONAL, + ricServiceInsertLoadRequest RICloadRequest OPTIONAL, + ricServiceControlLoadRequest RICloadRequest OPTIONAL, + ricServicePolicyLoadRequest RICloadRequest OPTIONAL, + ricServiceQueryLoadRequest RICloadRequest OPTIONAL, + ... +} + +RICsubscriptionTime ::= OCTET STRING (SIZE(8)) + +RICsubsequentAction ::=SEQUENCE{ + ricSubsequentActionType RICsubsequentActionType, + ricTimeToWait RICtimeToWait, + ... +} + +RICsubscriptionAuditFlag ::= SEQUENCE{ + listedRecordsOnly ListedRecordsOnly OPTIONAL, + ... +} + +RICsubsequentActionType ::= ENUMERATED{ + continue, + wait, + ... +} + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICQueryHeader ::= OCTET STRING + +-- ***** +-- Following IE defined in E2SM +-- ***** +RICQueryDefinition ::= OCTET STRING + +-- ***** +-- Following IE defined in E2SM +-- ***** + +``` + +``` +RICQueryOutcome ::= OCTET STRING +``` + +``` +RICTimeToWait ::= ENUMERATED{ +``` + +``` + w1ms, + w2ms, + w5ms, + w10ms, + w20ms, + w30ms, + w40ms, + w50ms, + w100ms, + w200ms, + w500ms, + w1s, + w2s, + w5s, + w10s, + w20s, + w60s, + ... +} +``` + +``` +-- S +``` + +``` + +-- Following IE defined in E2SM + +``` + +``` +ServiceLayerCause ::= OCTET STRING +``` + +``` +-- T +``` + +``` + +-- copied from 3GPP 38.413 (NGAP) IEs + +``` + +``` +TimeToWait ::= ENUMERATED {v1s, v2s, v5s, v10s, v20s, v60s, ...} +``` + +``` +TNInformation ::= SEQUENCE{ + tnlAddress BIT STRING (SIZE(1..160,...)), + tnlPort BIT STRING (SIZE(16)) OPTIONAL, + ... +} +``` + +``` +TNLusage ::= ENUMERATED{ric-service, support-function, both, ...} +``` + +``` +TransactionID ::= INTEGER (0..255,...) +``` + +``` + +-- copied from 3GPP 38.413 (NGAP) IEs + +``` + +``` +TypeError ::= ENUMERATED { + not-understood, + missing, + ... +} +``` + +``` +-- U +``` + +``` +-- V +``` + +``` +-- W +``` + +``` +-- X +``` + +``` +-- Y +``` + +``` +-- Z +``` + +``` +END +``` + +``` +-- ASN1STOP +``` + +### 9.3.6 Common definitions + +``` +-- ASN1START +``` + +``` +-- ***** +-- +-- Common definitions +-- Derived from 3GPP 38.413 (NGAP) +-- +-- ***** + +E2AP-CommonDataTypes { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version2 (2) +e2ap(1) e2ap-CommonDataTypes (3) } + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +Criticality ::= ENUMERATED { reject, ignore, notify } + +Presence ::= ENUMERATED { optional, conditional, mandatory } + +ProcedureCode ::= INTEGER (0..255) + +ProtocolIE-ID ::= INTEGER (0..65535) + +TriggeringMessage ::= ENUMERATED { initiating-message, successful-outcome, unsuccessful-outcome } + +END +-- ASN1STOP +``` + +### 9.3.7 Constant definitions + +``` +-- ASN1START +-- ***** +-- +-- Constant definitions +-- +-- ***** + +E2AP-Constants { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version2 (2) +e2ap(1) e2ap-Constants (4) } + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +IMPORTS + ProcedureCode, + ProtocolIE-ID +FROM E2AP-CommonDataTypes; + +-- ***** +-- +-- Elementary Procedures +-- +-- ***** +id-E2setup ProcedureCode ::= 1 +id-ErrorIndication ProcedureCode ::= 2 +id-Reset ProcedureCode ::= 3 +id-RICcontrol ProcedureCode ::= 4 +id-RICindication ProcedureCode ::= 5 +id-RICserviceQuery ProcedureCode ::= 6 +id-RICserviceUpdate ProcedureCode ::= 7 +id-RICsubscription ProcedureCode ::= 8 +id-RICsubscriptionDelete ProcedureCode ::= 9 +id-E2nodeConfigurationUpdate ProcedureCode ::= 10 +id-E2connectionUpdate ProcedureCode ::= 11 +id-RICsubscriptionDeleteRequired ProcedureCode ::= 12 +id-E2removal ProcedureCode ::= 13 +id-RICsubscriptionModification ProcedureCode ::= 14 +id-RICsubscriptionModificationRequired ProcedureCode ::= 15 +``` + +``` + +id-RIQuery ProcedureCode ::= 16 +id-RIsubscriptionAudit ProcedureCode ::= 17 +id-RIserviceLoadStatus ProcedureCode ::= 18 +id-RIserviceLoadUpdate ProcedureCode ::= 19 +id-RIsubscriptionStateControl ProcedureCode ::= 20 +id-RIassistance ProcedureCode ::= 21 +id-RIassistanceIndication ProcedureCode ::= 22 +id-RIassistanceHalt ProcedureCode ::= 23 + +-- ***** +-- +-- Extension constants +-- +-- ***** + +maxProtocolIEs INTEGER ::= 65535 + +-- ***** +-- +-- Lists +-- +-- ***** +maxnoofErrors INTEGER ::= 256 +maxofE2nodeComponents INTEGER ::= 1024 +maxofRANfunctionID INTEGER ::= 256 +maxofRICactionID INTEGER ::= 16 +maxofTNLA INTEGER ::= 32 +maxofRICrequestID INTEGER ::= 1024 +maxofRICsubscriptions INTEGER ::= 2147483648 + +-- ***** +-- +-- IEs +-- +-- ***** +id-Cause ProtocolIE-ID ::= 1 +id-CriticalityDiagnostics ProtocolIE-ID ::= 2 +id-GlobalE2node-ID ProtocolIE-ID ::= 3 +id-GlobalRIC-ID ProtocolIE-ID ::= 4 +id-RANfunctionID ProtocolIE-ID ::= 5 +id-RANfunctionID-Item ProtocolIE-ID ::= 6 +id-RANfunctionIEcause-Item ProtocolIE-ID ::= 7 +id-RANfunction-Item ProtocolIE-ID ::= 8 +id-RANfunctionsAccepted ProtocolIE-ID ::= 9 +id-RANfunctionsAdded ProtocolIE-ID ::= 10 +id-RANfunctionsDeleted ProtocolIE-ID ::= 11 +id-RANfunctionsModified ProtocolIE-ID ::= 12 +id-RANfunctionsRejected ProtocolIE-ID ::= 13 +id-RIAction-Admitted-Item ProtocolIE-ID ::= 14 +id-RIActionID ProtocolIE-ID ::= 15 +id-RIAction-NotAdmitted-Item ProtocolIE-ID ::= 16 +id-RIActions-Admitted ProtocolIE-ID ::= 17 +id-RIActions-NotAdmitted ProtocolIE-ID ::= 18 +id-RIAction-ToBeSetup-Item ProtocolIE-ID ::= 19 +id-RIcallProcessID ProtocolIE-ID ::= 20 +id-RIcontrolAckRequest ProtocolIE-ID ::= 21 +id-RIcontrolHeader ProtocolIE-ID ::= 22 +id-RIcontrolMessage ProtocolIE-ID ::= 23 +id-RIcontrolStatus ProtocolIE-ID ::= 24 +id-RIindicationHeader ProtocolIE-ID ::= 25 +id-RIindicationMessage ProtocolIE-ID ::= 26 +id-RIindicationSN ProtocolIE-ID ::= 27 +id-RIindicationType ProtocolIE-ID ::= 28 +id-RIrequestID ProtocolIE-ID ::= 29 +id-RIsubscriptionDetails ProtocolIE-ID ::= 30 +id-TimeToWait ProtocolIE-ID ::= 31 +id-RIcontrolOutcome ProtocolIE-ID ::= 32 +id-E2nodeComponentConfigUpdate ProtocolIE-ID ::= 33 +id-E2nodeComponentConfigUpdate-Item ProtocolIE-ID ::= 34 + +``` + +| | | +|-----------------------------------------------------|-----------------------| +| id-E2nodeComponentConfigUpdateAck | ProtocolIE-ID ::= 35 | +| id-E2nodeComponentConfigUpdateAck-Item | ProtocolIE-ID ::= 36 | +| id-E2connectionSetup | ProtocolIE-ID ::= 39 | +| id-E2connectionSetupFailed | ProtocolIE-ID ::= 40 | +| id-E2connectionSetupFailed-Item | ProtocolIE-ID ::= 41 | +| id-E2connectionFailed-Item | ProtocolIE-ID ::= 42 | +| id-E2connectionUpdate-Item | ProtocolIE-ID ::= 43 | +| id-E2connectionUpdateAdd | ProtocolIE-ID ::= 44 | +| id-E2connectionUpdateModify | ProtocolIE-ID ::= 45 | +| id-E2connectionUpdateRemove | ProtocolIE-ID ::= 46 | +| id-E2connectionUpdateRemove-Item | ProtocolIE-ID ::= 47 | +| id-TNLinformation | ProtocolIE-ID ::= 48 | +| id-TransactionID | ProtocolIE-ID ::= 49 | +| id-E2nodeComponentConfigAddition | ProtocolIE-ID ::= 50 | +| id-E2nodeComponentConfigAddition-Item | ProtocolIE-ID ::= 51 | +| id-E2nodeComponentConfigAdditionAck | ProtocolIE-ID ::= 52 | +| id-E2nodeComponentConfigAdditionAck-Item | ProtocolIE-ID ::= 53 | +| id-E2nodeComponentConfigRemoval | ProtocolIE-ID ::= 54 | +| id-E2nodeComponentConfigRemoval-Item | ProtocolIE-ID ::= 55 | +| id-E2nodeComponentConfigRemovalAck | ProtocolIE-ID ::= 56 | +| id-E2nodeComponentConfigRemovalAck-Item | ProtocolIE-ID ::= 57 | +| id-E2nodeTNLassociationRemoval | ProtocolIE-ID ::= 58 | +| id-E2nodeTNLassociationRemoval-Item | ProtocolIE-ID ::= 59 | +| id-RICsubscriptionToBeRemoved | ProtocolIE-ID ::= 60 | +| id-RICsubscription-withCause-Item | ProtocolIE-ID ::= 61 | +| id-RICsubscriptionStartTime | ProtocolIE-ID ::= 62 | +| id-RICsubscriptionEndTime | ProtocolIE-ID ::= 63 | +| id-RICeventTriggerDefinitionToBeModified | ProtocolIE-ID ::= 64 | +| id-RICactionsToBeRemovedForModification-List | ProtocolIE-ID ::= 65 | +| id-RICaction-ToBeRemovedForModification-Item | ProtocolIE-ID ::= 66 | +| id-RICactionsToBeModifiedForModification-List | ProtocolIE-ID ::= 67 | +| id-RICaction-ToBeModifiedForModification-Item | ProtocolIE-ID ::= 68 | +| id-RICactionsToBeAddedForModification-List | ProtocolIE-ID ::= 69 | +| id-RICaction-ToBeAddedForModification-Item | ProtocolIE-ID ::= 70 | +| id-RICactionsRemovedForModification-List | ProtocolIE-ID ::= 71 | +| id-RICaction-RemovedForModification-Item | ProtocolIE-ID ::= 72 | +| id-RICactionsFailedToBeRemovedForModification-List | ProtocolIE-ID ::= 73 | +| id-RICaction-FailedToBeRemovedForModification-Item | ProtocolIE-ID ::= 74 | +| id-RICactionsModifiedForModification-List | ProtocolIE-ID ::= 75 | +| id-RICaction-ModifiedForModification-Item | ProtocolIE-ID ::= 76 | +| id-RICactionsFailedToBeModifiedForModification-List | ProtocolIE-ID ::= 77 | +| id-RICaction-FailedToBeModifiedForModification-Item | ProtocolIE-ID ::= 78 | +| id-RICactionsAddedForModification-List | ProtocolIE-ID ::= 79 | +| id-RICaction-AddedForModification-Item | ProtocolIE-ID ::= 80 | +| id-RICactionsFailedToBeAddedForModification-List | ProtocolIE-ID ::= 81 | +| id-RICaction-FailedToBeAddedForModification-Item | ProtocolIE-ID ::= 82 | +| id-RICactionsRequiredToBeModified-List | ProtocolIE-ID ::= 83 | +| id-RICaction-RequiredToBeModified-Item | ProtocolIE-ID ::= 84 | +| id-RICactionsRequiredToBeRemoved-List | ProtocolIE-ID ::= 85 | +| id-RICaction-RequiredToBeRemoved-Item | ProtocolIE-ID ::= 86 | +| id-RICactionsConfirmedForModification-List | ProtocolIE-ID ::= 87 | +| id-RICaction-ConfirmedForModification-Item | ProtocolIE-ID ::= 88 | +| id-RICactionsRefusedToBeModified-List | ProtocolIE-ID ::= 89 | +| id-RICaction-RefusedToBeModified-Item | ProtocolIE-ID ::= 90 | +| id-RICactionsConfirmedForRemoval-List | ProtocolIE-ID ::= 91 | +| id-RICaction-ConfirmedForRemoval-Item | ProtocolIE-ID ::= 92 | +| id-RICactionsRefusedToBeRemoved-List | ProtocolIE-ID ::= 93 | +| id-RICaction-RefusedToBeRemoved-Item | ProtocolIE-ID ::= 94 | +| id-RICqueryHeader | ProtocolIE-ID ::= 95 | +| id-RICqueryDefinition | ProtocolIE-ID ::= 96 | +| id-RICqueryOutcome | ProtocolIE-ID ::= 97 | +| id-RICsubscriptionAuditFlag | ProtocolIE-ID ::= 98 | +| id-RICsubscriptionAuditList | ProtocolIE-ID ::= 99 | +| id-RICsubscriptionAudit-Item | ProtocolIE-ID ::= 100 | +| id-RICsubscriptionAuditAction-Item | ProtocolIE-ID ::= 101 | +| id-RICsubscriptionAuditConfirmedList | ProtocolIE-ID ::= 102 | +| id-RICsubscriptionAuditMissingList | ProtocolIE-ID ::= 103 | +| id-RICsubscriptionAuditUnknownList | ProtocolIE-ID ::= 104 | +| id-E2nodeLoadMeasurementID | ProtocolIE-ID ::= 105 | +| id-RANfunctionLoad-Item | ProtocolIE-ID ::= 106 | +| id-RANfunctionLoad-List | ProtocolIE-ID ::= 107 | + +``` + +id-RANfunctionLoadConfirm-Item ProtocolIE-ID ::= 108 +id-RANfunctionLoadConfirm-List ProtocolIE-ID ::= 109 +id-RANfunctionLoadRequest-Item ProtocolIE-ID ::= 110 +id-RANfunctionLoadRequest-List ProtocolIE-ID ::= 111 +id-RegistrationRequest ProtocolIE-ID ::= 112 +id-ReportingPeriodicity ProtocolIE-ID ::= 113 +id-RICactionLoad-Item ProtocolIE-ID ::= 114 +id-RICactionLoadConfirm-Item ProtocolIE-ID ::= 115 +id-RICactionLoadRequest-Item ProtocolIE-ID ::= 116 +id-RICloadMeasurementID ProtocolIE-ID ::= 117 +id-RICsubscriptionLoad-Item ProtocolIE-ID ::= 118 +id-RICsubscriptionLoadConfirm-Item ProtocolIE-ID ::= 119 +id-RICsubscriptionLoadRequest-Item ProtocolIE-ID ::= 120 +id-RANfunctionStateConfirm-Item ProtocolIE-ID ::= 121 +id-RANfunctionStateConfirm-List ProtocolIE-ID ::= 122 +id-RANfunctionStateControl-Item ProtocolIE-ID ::= 123 +id-RANfunctionStateControl-List ProtocolIE-ID ::= 124 +id-RICactionList-Item ProtocolIE-ID ::= 125 +id-RICsubscriptionList-Item ProtocolIE-ID ::= 126 +id-RICassistanceHeader ProtocolIE-ID ::= 127 +id-RICassistanceMessage ProtocolIE-ID ::= 128 +id-RICassistanceOutcome ProtocolIE-ID ::= 129 +id-RICassistanceSN ProtocolIE-ID ::= 130 +id-RICassistanceUpdate ProtocolIE-ID ::= 131 +id-RICassistanceUpdateNumber ProtocolIE-ID ::= 132 +END +-- ASN1STOP + +``` + +### 9.3.8 Container definitions + +``` + +-- ASN1START +-- +-- +-- Container definitions +-- +-- derived from 3GPP 38.413 (NGAP) +-- + +E2AP-Containers { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version2 (2) +e2ap(1) e2ap-Containers (5) } + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +-- +-- +-- IE parameter types from other modules. +-- +-- + +IMPORTS + + Criticality, + Presence, + ProtocolIE-ID +FROM E2AP-CommonDataTypes + + maxProtocolIEs +FROM E2AP-Constants; + +-- +-- +-- Class Definition for Protocol IEs +-- +-- + +E2AP-PROTOCOL-IES ::= CLASS { + &id ProtocolIE-ID UNIQUE, + +``` + +``` + + &criticality Criticality, + &Value, + &presence Presence + } + WITH SYNTAX { + ID &id + CRITICALITY &criticality + TYPE &Value + PRESENCE &presence + } + +-- ***** +-- +-- Class Definition for Protocol IEs +-- +-- ***** + +E2AP-PROTOCOL-IES-PAIR ::= CLASS { + &id ProtocolIE-ID UNIQUE, + &firstCriticality Criticality, + &FirstValue, + &secondCriticality Criticality, + &SecondValue, + &presence Presence +} +WITH SYNTAX { + ID &id + FIRST CRITICALITY &firstCriticality + FIRST TYPE &FirstValue + SECOND CRITICALITY &secondCriticality + SECOND TYPE &SecondValue + PRESENCE &presence +} + +-- ***** +-- +-- Container for Protocol IEs +-- +-- ***** + +ProtocolIE-Container {E2AP-PROTOCOL-IES : IEsSetParam} ::= + SEQUENCE (SIZE (0..maxProtocolIEs)) OF + ProtocolIE-Field {{IEsSetParam}} + +ProtocolIE-SingleContainer {E2AP-PROTOCOL-IES : IEsSetParam} ::= + ProtocolIE-Field {{IEsSetParam}} + +ProtocolIE-Field {E2AP-PROTOCOL-IES : IEsSetParam} ::= SEQUENCE { + id E2AP-PROTOCOL-IES.&id {{IEsSetParam}}, + criticality E2AP-PROTOCOL-IES.&criticality {{IEsSetParam}}{@id}}, + value E2AP-PROTOCOL-IES.&Value {{IEsSetParam}}{@id}} +} + +-- ***** +-- +-- Container for Protocol IE Pairs +-- +-- ***** + +ProtocolIE-ContainerPair {E2AP-PROTOCOL-IES-PAIR : IEsSetParam} ::= + SEQUENCE (SIZE (0..maxProtocolIEs)) OF + ProtocolIE-FieldPair {{IEsSetParam}} + +ProtocolIE-FieldPair {E2AP-PROTOCOL-IES-PAIR : IEsSetParam} ::= SEQUENCE { + id E2AP-PROTOCOL-IES-PAIR.&id {{IEsSetParam}}, + firstCriticality E2AP-PROTOCOL-IES-PAIR.&firstCriticality {{IEsSetParam}}{@id}}, + firstValue E2AP-PROTOCOL-IES-PAIR.&FirstValue {{IEsSetParam}}{@id}}, + secondCriticality E2AP-PROTOCOL-IES-PAIR.&secondCriticality {{IEsSetParam}}{@id}}, + +``` + +``` + + secondValue E2AP-PROTOCOL-IES-PAIR.&SecondValue ({IEsSetParam}{@id}) + } + +-- +-- Container Lists for Protocol IE Containers +-- + + +ProtocolIE-ContainerList {INTEGER : lowerBound, INTEGER : upperBound, E2AP-PROTOCOL-IES : IEsSetParam} ::= + SEQUENCE (SIZE (lowerBound..upperBound)) OF + ProtocolIE-SingleContainer {{IEsSetParam}} + +ProtocolIE-ContainerPairList {INTEGER : lowerBound, INTEGER : upperBound, E2AP-PROTOCOL-IES-PAIR : +IEsSetParam} ::= + SEQUENCE (SIZE (lowerBound..upperBound)) OF + ProtocolIE-ContainerPair {{IEsSetParam}} + +END +-- ASN1STOP + +``` + +## 9.4 Message transfer syntax + +E2AP shall use the ASN.1 Basic Packed Encoding Rules (BASIC-PER) Aligned Variant as transfer syntax, as specified in Recommendation ITU-T X.691 [15]. + +## 9.5 Timers + +The following Timers are defined for use over the E2 interface in Near-RT RIC and E2 Node. + +$T_{\text{RICEVENTcreate}}$ + +- Specifies the maximum time for the RIC Subscription procedure in the Near-RT RIC. + +$T_{\text{RICEVENTdelete}}$ + +- Specifies the maximum time for the RIC Subscription Deletion procedure in the Near-RT RIC. + +$T_{\text{RICEVENTmodify}}$ + +- Specifies the maximum time for the RIC Subscription Modification procedure in the Near-RT RIC. + +$T_{\text{RICcontrol}}$ + +- Specifies the maximum time for the RIC Control procedure in the Near-RT RIC. + +$T_{\text{RICquery}}$ + +- Specifies the maximum time for the RIC Query procedure in the Near-RT RIC. + +# --- 10 Handling of unknown, unforeseen and erroneous protocol data + +Clause 10 of 3GPP TS 36.413 [24] is applicable for the purposes of the present document. + +# Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2020.01.22 | 01.00.00 | <b>Specification renamed v01.00.00 for approval</b> | +| 2020.01.28 | 01.00.00 | <b>Initial version</b> | +| | | | +| 2020.07.08 | 01.00.01 | Addition of CR adopted during meeting #60 | +| 2020.07.13 | 01.00.02 | ASN.1 corrections, Table correction to align with ASN.1 | +| 2020.07.15 | 01.01 | <b>Editorial and functional corrections</b> | +| | | | +| 2021.01.13 | 02.00.01 | Addition of CR <RSY-2021.01.13-WG3-CR-0001-E2AP Spec v1.01 Corrections-v14> agreed at WG3#80 meeting, plus editorial corrections | +| 2021.04.21 | 02.00.02 | Addition of CRs<br><NOK-2021.03.02-WG3-E2AP-CR-0002-TNLA removal-v01.docx > agreed at WG3#88<br><NOK.AO-2021.01.26-WG3-CR-0001-E2AP-RANconfig-v04.docx> agreed at WG3#94 | +| 2021.05.27 | 02.00.03 | Addition of CR<br><INT-2021.05.26-WG3-CR-0005-E2AP-RICsubs_delete.docx> agreed at WG3#99.<br>Endorsed WG3#100 | +| 2021.06.09 | 02.00.04 | Addition of CR: < NOK.AO-2021.05.26-WG3-CR-0003-E2AP-RIC control-v01> agreed at WG3#100<br>Re-implementation of part of <NOK.AO-2021.01.26-WG3-CR-0001-E2AP-RANconfig-v04.docx> agreed at WG3#94 correcting error introduced in v02.00.02 | +| 2021.07.11 | 02.00.05 | NOK-2021-06-09.WG3.CR-0004-E2AP-v02.00.04editorials-v01 | +| 2021.08.10 | 02.00 | <b>New features: RIC Subscription Delete, TNLA Removal. Corrections to all RIC service procedures. Change to ASN.1 version</b> | +| | | | +| 2021.09.20 | 02.01.00 | Addition of CR < NOK-2021.09.01-WG3-CR-0006-E2APv2.0-errata9.3.7-v01 > | +| 2021.11.02 | 02.01.01 | Addition of CR <SAM-2021.10.19-WG3-CR-0001-E2AP_E2Removal-v03 > approved WG3#117<br>Aligned format for July21 publication changes | +| 2021.11.22 | 02.01.02 | Corrections based on E2APv02.01 WG3 approval review process | +| 2022.02.07 | 02.01 | <b>New feature: E2 removal. Editorial and functional corrections</b> | +| | | | +| 2022.02.08 | 02.02.01 | Addition of CR < NOK.AO-2022.01.05-WG3-CR-0008-E2AP-Global-gNB-ID-v01 > approved at WG3#127 | +| 2022.03.25 | 02.02.02 | Addition of CRs approved at WG3#134<br>< NOK.AO-2022.02.21-WG3-CR-0010-E2AP-RIC Service Query clarification-v01><br>< NEC-2022.02.28-WG3-CR-0002-E2AP- RIC CONTROL FAILURE -v03><br>< NOK.AO-2022.03.03-WG3-CR-0012-E2AP-RIC Service Update Ack clarification-v02><br>< NOK-2022.01.03-WG3-CR-0011-E2AP-Reducing MAX limits-v02> approved at WG3#137<br>Note: This version contains non-backward compatible change with respect to v02.01 impacting RIC Subscription Delete Required message | +| 2022.04.04 | 02.02.03 | Editorial changes based on remarks during WG3 approval | +| 2022.06.29 | 02.02 | <b>Clarification to RIC Service Update, RIC Control. Editorial and functional corrections</b> | +| | | | +| 2022.06.20 | 02.02.04 | Addition of CR < NOK.AO-2022.05.24-WG3-CR-0013-E2AP-EditorialCorrections-v02 > | +| 2022.07.15 | 02.02.05 | Addition of <NOK.AO-2022.06.24-WG3-CR-0015-E2AP-RIC Service Update Ack (ASN.1)-v03> | +| 2022.07.20 | 02.03 | <b>Editorial and functional corrections</b> | +| | | | + +| Date | Revision | Description | +|-------------------|--------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.11.02 | 02.03.01 | Addition of CR:<br>< NOK.AO-2022.09.02-WG3-CR-0017-E2AP-RIC Subscription duration limit-v06 ><br>< NOK-2022.09.01-WG3-CR-0016-E2AP-E1AP reference correction-v03 >, error in CR corrected (ref [21] should be 37.483)<br>Addition of “skin rose” to all PlantUML code to restore O-RAN look | +| 2022.11.10 | 02.03.02 | Editorial changes:<br>- Correction to ASN.1 (correcting error in E2APv02.03.01)<br>- Rearrangement of Table 8.1-1: Class 1 Elementary Procedures<br>- Added missing Timer definitions<br><br>Addition of CRs:<br>< NOK-2022.06.21-WG3-CR-0014-E2AP-RIC subscription handling improvements-v06>,<br>error in CR corrected (ASN.1 for Cause value aligned to name in 9.2.1)<br>< MAV.AO-2022.03.03-WG3-CR-0014.E2AP 02.03 RIC_Subscription_Modification procedure-v15><br><QCM.AO-2022.09.08-WG3-CR-0002-E2AP-RIC_Query_Procedure_v11>, error in CR corrected (ASN.1 for Cause value aligned to name in 9.2.1) | +| 2022.11.16 | 02.03.03 | Changes reflecting remarks received during WG3 approval process<br>- Alignment to latest O-RAN template<br>- Added R003 to file name<br>- Updated copyright year<br>- Removed “RIC Action Type” from RIC Subscription Modification to align with late submitted revised CR (impacts 8.2.5, 9.1.1.11, 9.3.4)<br>- Corrected errors in CRs implemented in previous drafts<br>- Corrected ASN.1 label “gNB-CU-CP-ID” to read “gNB-CU-UP-ID” in section 9.3.5 | +| <b>2022.12.07</b> | <b>03.00</b> | <b>New features: RIC Subscription Modification, RIC Query. Clarifications to RIC Subscription. Editorial and functional corrections</b> | +| | | | +| 2023.01.27 | 03.00.01 | CR < NOK-2023.01.09-WG3-CR-0019-E2AP-PAS step1-v01 > approved WG3#171 | +| 2023.02.16 | 03.00.02 | CR <NOK-2023.02.15-WG3-CR-0020-E2AP-PAS step2-v02> approved Prague F2F 16/2/2023 | +| 2023.03.17 | 03.00.03 | CR <NOK-2023.03.13-WG3-CR-0021-E2AP-PAS step3-v4> approved by correspondence after WG3#176 | +| 2023.03.24 | 03.00.04 | Inclusion of corrections agreed during WG3 approval process as per < O-RAN.WG3.E2AP-R003-v03.00.03-approvalChanges-v3 > | +| <b>2023.03.24</b> | <b>03.01</b> | <b>Alignment of O-RAN Drafting Rules (ODR) in preparation for ETSI PAS submission</b> | +| | | | +| 2023.05.15 | 03.01.01 | CR <NOK-2023.04.28-WG3-CR-0022-E2AP-Correction to clause 2.1-v01> approved WG3#183 | +| 2023.06.27 | 03.01.02 | CR <NOK-2023.05.26-WG3-CR-0024-E2AP-Critical ASN.1 correction-v01> approved WG3#189 | +| 2023.07.11 | 03.01.03 | CR <SAM.AO-2023.05.10-WG3-CR-0001-E2AP-E2 Nod Component Configuration-v04> approved WG3#189 | +| 2023.07.26 | 03.01.04 | Editorial corrections based on comments received during WG3 poll. | +| 2023.07.28 | 03.01.05 | Editorial changes to align to O-RAN TS template v01.01 | +| <b>2023.07.28</b> | <b>04.00</b> | <b>Clarification on E2 Node components configuration. Editorial and functional corrections</b> | +| | | | + +| Date | Revision | Description | +|-------------------|--------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.10.04 | 04.00.01 | CR <NOK.AO-2023.05.22-WG3-CR-0023-E2AP-SubscriptionAudit-v10.docx> approved WG3#201 and editorial corrections to figure title text. | +| 2023.11.15 | 04.00.02 | Editorial corrections implementing WG3 voting period feedback | +| 2023.11.21 | 04.00.03 | Restored full revision history into Annex: Change History and deletion of Annex: History | +| <b>2023.11.21</b> | <b>05.00</b> | <b>New feature: RIC Subscription Audit. Editorial and functional corrections</b> | +| 2024.02.29 | 05.00.01 | CR <NOK-2023.11.24-WG3-CR-0025-E2AP-Cleanup-v01> approved WG3#207<br>CR <NOK-2024.02.13-WG3-CR-0026-E2AP-Change history-v01> approved F2F Athens | +| 2024.05.22 | 05.00.02 | CR < NOK-2024.04.09-WG3-CR-0027-E2AP-Editorial corrections for PAS-step4-v04> approved WG3#225<br>Also includes editorial changes to align with ETSI “Edit Help” changes during PAS processing of v04.00 | +| 2024.06.21 | 05.00.03 | CR <NOK-2025.06.04-E2AP-CR-0028-Clause 8.2.1.3 inconsistency term-v01> approved WG3 Incheon F2F<br>CR <NOK-2025.06.04-E2AP-CR-0029-Clause 8.2.3.2 changes for PAS-v01> approved WG3 Incheon F2F<br>CR < NOK-2025.06.04-E2AP-CR-0030-Clause 8.2.5.3+8.2.6.3 changes for PAS-v02 > approved WG3 Incheon F2F<br>CR <NOK-2025.06.04-E2AP-CR-0031-Clause 8.2.7.3 changes for PAS-v01> approved WG3 Incheon F2F<br>CR <NOK-2025.06.19-E2AP-CR-0032-Splitting Clause 8.3.4 RIC Service Update-v01> approved WG3#230 | +| 2024.07.26 | 05.00.04 | Editorial corrections implementing review comments collected during July24 train approval | +| <b>2024.07.26</b> | <b>06.00</b> | <b>Alignment to ETSI Drafting Rules and implementation of all agreed ETSI PAS comments</b> | +| 2024.10.09 | 06.00.01 | CR <NOK-2024.09.27-E2AP-CR-0034-EditHelp alignment-v1> approved WG3#241 | +| 2024.11.22 | 06.00.02 | Editorial changes to align with O-RAN WORKPROC v04.00<br>CR <NOK-2024.10.23-WG3-CR-0036-E2AP-Handling LS from MSG-v04> approved F2F Montreal<br>CR < NOK-2024.10.1-E2AP-CR-0035-ErrorHandling added in Cause - v06> approved WG3 ArchTG#113<br>CR <NOK.AO-2024.09.16-WG3-CR-0033-E2AP-E2 Overload-v05> approved WG3 ArchTG#113<br>CR < NOK.AO-2024.09.16-WG3-CR-0037-E2AP-RIC Subscription State Control-v4> approved WG3 ArchTG#113<br>CR < NOK-2024.11.13-WG3-CR-0039-E2AP-Clause 9.3.1 correction-v1> approved WG3#245<br>CR < NOK-2024.11.08-E2AP-CR-0038-RIC Assistance-v06> approved WG3#245<br>Editorial corrections to clause 9.2 and ASN.1 | +| 2024.12.03 | 06.00.03 | CR <LGE-2024.10.25-WG3-CR-0002-E2AP-Correction_RICaudit_v01> approved F2F Montreal<br>Editorial corrections implementing comments received during Nov24 train approval process | +| <b>2024.12.04</b> | <b>07.00</b> | <b>New features: RIC Subscription State Control, RIC Assistance, Service Level error handling. Implementation of changes related to ETSI MSG Liaison</b> | +| | | | \ No newline at end of file diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/118251355d912bbd2f8fe0cb566ba91b_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/118251355d912bbd2f8fe0cb566ba91b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..41376671057aa7fa9f34e7ec2d3125aab9fc4848 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/118251355d912bbd2f8fe0cb566ba91b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd0896eeaab08b6bf4a8ed8f7623a19ff0359fe94c02e6e018537ee45dbcb08b +size 4554 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/142e19b0b998f26887c55684260096fc_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/142e19b0b998f26887c55684260096fc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..61abb9cb67add91e334f772afe2a7536ac6f6051 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/142e19b0b998f26887c55684260096fc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:603d50f609012ba7131f4cc28a279d925a9f19a8e9438f0c6233c3e35d65ad22 +size 87650 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/2102608ef99c843aead1d53ffd6d7e49_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/2102608ef99c843aead1d53ffd6d7e49_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..464d4666d6010faedb264bd46c3c72298d38698d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/2102608ef99c843aead1d53ffd6d7e49_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e300891711632df4a5c0a7bc052abbd40ec7fe200543a5874ec289602d831cda +size 188840 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/255e3a388f714539439c5cfa0fd89c90_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/255e3a388f714539439c5cfa0fd89c90_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..17a7982f52f88776ec7b8badaca68d9a3d0fd737 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/255e3a388f714539439c5cfa0fd89c90_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3a023edc65be85746c6b4a97c26710e43194aeb882db34c7e8d218d659299e72 +size 4523 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/29aa34df00d65c93f76a99751c9f2d57_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/29aa34df00d65c93f76a99751c9f2d57_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d71f40bc49da5f7db99b0a646dd0fdee5690dd9f --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/29aa34df00d65c93f76a99751c9f2d57_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d713e393b44529021dcea424c319a35bcd6188b5c8ce00a884104d312fe3a5cb +size 115454 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/2c389d82f021e3a8c3a836d8cb465c6f_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/2c389d82f021e3a8c3a836d8cb465c6f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2654d342ebf6f3ae42f4207739252b08f4e1b399 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/2c389d82f021e3a8c3a836d8cb465c6f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:52ba0bd2321a9e4f0de7dc11e8ac1ed6614b810a58e84c6f6b050800c91ae872 +size 110109 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/33771de5f196201ae695abbd356a8666_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/33771de5f196201ae695abbd356a8666_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..60a7668ae25993a698cd8136b84db6cec16d1194 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/33771de5f196201ae695abbd356a8666_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ad4e6f857fd9b94cdcd6c731792cf8f2a7e2da6301712a279afea29c4a5fdb0 +size 57762 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/345e11b5b10680b0659eacd37c4fbaea_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/345e11b5b10680b0659eacd37c4fbaea_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..df3017ed1a629a4cf5c54b2861c984d109453ba7 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/345e11b5b10680b0659eacd37c4fbaea_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:430108d013e0fc26ba579550d32df7bf5346a82114430c6fc7dc2e9e69a088e2 +size 175882 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/38db3420ebc08106dccb6f0ecc6a0d6e_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/38db3420ebc08106dccb6f0ecc6a0d6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de50d0a0cf2bec473e4ab494e0aaeb92d4219783 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/38db3420ebc08106dccb6f0ecc6a0d6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:670aedb94e8c2b1cac15a88c21c471ecd5d7ca775c0d54a923319ffde7def695 +size 4490 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/41132cba2afc71ce3efd85e5aa3b458e_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/41132cba2afc71ce3efd85e5aa3b458e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db0d0abfa36402fe34e954ef6cb89ad11b43a20f --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/41132cba2afc71ce3efd85e5aa3b458e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:080ab20e931d6d02565dfeac17eb75a6b99bd325fe171951afb96edbc0f25b1d +size 62977 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/528a5eff28fbb4b153e86f28d45e21e0_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/528a5eff28fbb4b153e86f28d45e21e0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..38ea711c1e76bc26505ea19a76a932c3d2551376 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/528a5eff28fbb4b153e86f28d45e21e0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2db705a15cf3379638b7407101b2620a74267404174a0fae2167606c33db14ae +size 57364 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/591890046c73f1ed213267987b143ebb_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/591890046c73f1ed213267987b143ebb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d5dc0d347f191f665d33f5c81ec0b289f361724d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/591890046c73f1ed213267987b143ebb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c05d48830aa7051fbe40cbb33243c9978ffdc2079f8bf40d9ab6117a56af7c8d +size 4542 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/6983a15c6166761930f3be4fc7311d8b_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/6983a15c6166761930f3be4fc7311d8b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d3b13216ce8aa6f8617965558e574d122a2938a8 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/6983a15c6166761930f3be4fc7311d8b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ba17514545b502cf09ece33838dc104718efd5e49bb2a06b725d850201b8f101 +size 76612 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/781f21186364aa7d3214ce432735de65_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/781f21186364aa7d3214ce432735de65_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0649a979ab45d5ca4d05790dd15aa0672c2a72be --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/781f21186364aa7d3214ce432735de65_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d94b2a1d0893144b576419cac796aefa4f5a694ec0c037bd7fa4859c501f4e00 +size 29110 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/88090d83e337f2a83f461378216f0810_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/88090d83e337f2a83f461378216f0810_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4b9cfc0d1fd907fc43486af7b2bc9cb00702840c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/88090d83e337f2a83f461378216f0810_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4bdab73a68f0fcf67b72c8cf40e90a4611de41b97d8db9048dcc8fe0a828cc50 +size 4482 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/88d0648b30c3d4c271897f352c4de4a5_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/88d0648b30c3d4c271897f352c4de4a5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0bb86b24594fcc59021f4530f31410dccd65ff33 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/88d0648b30c3d4c271897f352c4de4a5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2af85e75727134589950aa91678bd923ba581b044a64379a28725a7484347746 +size 4550 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/92d321eb2987f8a81950f3faedf1aa76_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/92d321eb2987f8a81950f3faedf1aa76_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bdf40b08b798590b658897d4494ac8c7d37601ab --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/92d321eb2987f8a81950f3faedf1aa76_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:588bf4ea68b6ad85094e05ee20b084affad859418ff7670ec534a74c77cf8545 +size 135481 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/92f2ea0f78ab36baf6cb383e860ec5be_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/92f2ea0f78ab36baf6cb383e860ec5be_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9a54696c8a32492e67014a67ebfc9c7ce65f180d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/92f2ea0f78ab36baf6cb383e860ec5be_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:53c6b97fb7ba5202dae5ae310e02d31ebbe6576eda979f27a7c928cdd6b0d4cd +size 50517 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/93c8b2ed3ba0ccb062b2f04ba5012b26_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/93c8b2ed3ba0ccb062b2f04ba5012b26_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dd77445a53269e5d77b92e4c5c6f439c5afc9d77 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/93c8b2ed3ba0ccb062b2f04ba5012b26_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3514b899bae1f14d419de09f69790b7c4f3cb4288c8178db4fd73493919218c0 +size 119857 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/a1ecef82c07a5943ace495a2d0c3cd50_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/a1ecef82c07a5943ace495a2d0c3cd50_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd33f4777b418218aeb794913deccafa5bc41553 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/a1ecef82c07a5943ace495a2d0c3cd50_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aea63f3e9cf7c5a9d033b3f9c4280604ab772548202f257bc28521ec695c6e6b +size 62342 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/a4625b8d31b820d7b6c97d2dff80eb40_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/a4625b8d31b820d7b6c97d2dff80eb40_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3711d34a399a447cf1fde6516397404e0d3fea8d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/a4625b8d31b820d7b6c97d2dff80eb40_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:658801a2690d5597cadac4fa07205f5c51c8f5398781583b9ce67e71bd850da9 +size 202766 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/a9adce18b696d8c554877de0bf88ef02_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/a9adce18b696d8c554877de0bf88ef02_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7073b1bdf7ea42435f9b99642b859384c0dbe106 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/a9adce18b696d8c554877de0bf88ef02_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:195d22f26de9c04673899ce8d1543a5321ca9bc2c8f7d8ae1699a498069c3c4f +size 4528 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/b2bb68c7cbd90703d1d55851c84edc77_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/b2bb68c7cbd90703d1d55851c84edc77_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cc73fa6a6354bc2099581a76d452f13d66c5729a --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/b2bb68c7cbd90703d1d55851c84edc77_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a913edc49a4dc34a710be83fd5c4d3689fbed3d5fbd658f3d80a0d7cd59c4dc2 +size 223664 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/b71b0b905ce74aceb5e607475d8b0814_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/b71b0b905ce74aceb5e607475d8b0814_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5b52386ec0a9f4552b92f5ec90cb154150e77217 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/b71b0b905ce74aceb5e607475d8b0814_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1526b62ebded394047a6ff95323ad0ed3b6e00730e928d25388c3a6fe9b48422 +size 149101 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/c19b48699f086c1ac69ce3595f074e46_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/c19b48699f086c1ac69ce3595f074e46_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..49e29d3dc5f1f4b68d395752a77efcfbce511f9a --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/c19b48699f086c1ac69ce3595f074e46_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0771792eab05c30c57cfb4295c5b071983b81c96c23dc5dec7d176054a6c008a +size 65173 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/c851a1825b11664b44eb7bf4dd486f40_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/c851a1825b11664b44eb7bf4dd486f40_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ea68638039aa15807d9bd49e04a8e72760f2fe21 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/c851a1825b11664b44eb7bf4dd486f40_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1f281e2d271505133f537f20f73998a43c59cda48c1bea1a12a91bdab9aa4dfe +size 96904 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d230f4b1b10b144ce53e6aaa89d77ca4_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d230f4b1b10b144ce53e6aaa89d77ca4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4fbbe84f458804aadfa83a98399b8c518c7fbd26 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d230f4b1b10b144ce53e6aaa89d77ca4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c675959aa7da38ffd5a00ddc769bcf24d3ae4126e3d21a25b63a4952c7ecf10f +size 23352 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d6158143a2ac9f97ed9822c4b534445d_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d6158143a2ac9f97ed9822c4b534445d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d39b03e4fb52002534876827f19ccdcef36dbb4c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d6158143a2ac9f97ed9822c4b534445d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b848b87a0789f3fe8cd0d30bda5c7b7c00ce797104829f2c8c73ce6127fc1482 +size 65919 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d8474ec6c5d09beb8478076fce3b0853_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d8474ec6c5d09beb8478076fce3b0853_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..79aec02c4eae4521ff0bffd0381cb1726e70cc87 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d8474ec6c5d09beb8478076fce3b0853_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f16cacb8f997bb8520fd1bf059c4742ef8f12b18dd8777247e972d10104bce91 +size 70662 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d932e28bdc9d91f907587cce9b49fd23_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d932e28bdc9d91f907587cce9b49fd23_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5980c2e59cc71aee55a1ad42dd6c6cda94e946bd --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/d932e28bdc9d91f907587cce9b49fd23_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2145211dacae4121c5192bec9441148d48c4bab5a630eeec94d0edb247bf0ff4 +size 80508 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/dadd1f94977abeaf71bcb106d150a167_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/dadd1f94977abeaf71bcb106d150a167_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b177f8a6700fcf11db8e22839b1ab4701095b793 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/dadd1f94977abeaf71bcb106d150a167_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d8c15a9ecccec8e83a4e4a966cbf0d8eba12173c6a0a11fbd33265d1934df35a +size 50687 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e1489ee09b106f99d7a4b88a4b8de33b_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e1489ee09b106f99d7a4b88a4b8de33b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..85cbdbe34b3378132f8fe28f0f8c4dbff15528df --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e1489ee09b106f99d7a4b88a4b8de33b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8544d88eec0dd1db2d4e893013c4740290ead69fb90e7514def120dbcc9e9674 +size 80150 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e7fb35b6f8cd6b609e7cda9f00a94ce2_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e7fb35b6f8cd6b609e7cda9f00a94ce2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..90537377a220acddc60c7d3814c610749194964e --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e7fb35b6f8cd6b609e7cda9f00a94ce2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:02e9486f529304a688e669611913a5d4222a39550dc81e085bfd213bb2912f4e +size 112668 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e8128caf2db01d603f0db227577ce583_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e8128caf2db01d603f0db227577ce583_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..120b551e4e552929a7623444e4f7447b26fee0be --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e8128caf2db01d603f0db227577ce583_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e297a2817787402deaec78d39ab8d800eb2e32e5fcf2b90bfb76a79e06d38c73 +size 98612 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e89ab438de3870b6c4bd129c13f8a1ae_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e89ab438de3870b6c4bd129c13f8a1ae_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a6420f9addc07588b673e783759da8fa13582159 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/e89ab438de3870b6c4bd129c13f8a1ae_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:249aeb07aac16cdb3842400d4d9b5909449315a546cea26441784da8e6dad3a9 +size 31513 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/fa2335b22d10571686c714dacaa779e7_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/fa2335b22d10571686c714dacaa779e7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..afd7b3037de26d1b48f4ebb08930cc644ae338da --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/fa2335b22d10571686c714dacaa779e7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:026791746a381df61bb3619daf26fa0b58c9c9f46b2c67b73aec59f9eaaaf7a1 +size 57167 diff --git a/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/raw.md b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..34e540b974376672a1ebd828577f0bb117779e44 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00/raw.md @@ -0,0 +1,1552 @@ + + +# --- **O-RAN Work Group 3 (Near-RT RIC and E2 Interface)****E2 General Aspects and Principles (E2GAP)** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +"© 2020. 3GPP™ TSs and TRs are the property of ARIB, ATIS, CCSA, ETSI, TSDSI, TTA and TTC who jointly own the copyright in them. They are subject to further modifications and are therefore provided to you "as is" for information purposes only. Further use is strictly prohibited." + +# Contents + +| | | +|-----------------------------------------------------------------------------|----| +| List of figures..... | 5 | +| List of tables ..... | 5 | +| Foreword..... | 6 | +| Modal verbs terminology..... | 6 | +| 1 Scope ..... | 7 | +| 2 References ..... | 7 | +| 2.1 Normative references ..... | 7 | +| 2.2 Informative references..... | 8 | +| 3 Definition of terms, symbols and abbreviations ..... | 8 | +| 3.1 Terms..... | 8 | +| 3.2 Symbols..... | 8 | +| 3.3 Abbreviations ..... | 9 | +| 4 E2 interface architecture..... | 9 | +| 4.1 General architecture principles ..... | 9 | +| 4.2 O-RAN architecture considerations..... | 9 | +| 5 E2 interface ..... | 11 | +| 5.1 E2 interface requirements and general principles..... | 11 | +| 5.1.1 E2 interface requirements ..... | 11 | +| 5.1.2 E2 interface general principles..... | 11 | +| 5.2 E2 interface specification objectives ..... | 12 | +| 5.3 Functions of the E2 interface..... | 12 | +| 5.3.1 General..... | 12 | +| 5.3.2 RIC services and related procedures ..... | 13 | +| 5.3.3 Combining RIC services within a common RIC Subscription ..... | 28 | +| 5.3.4 Combining RIC services as a sequence of RIC services..... | 28 | +| 5.4 RAN Function E2 Service Model..... | 29 | +| 5.5 Global procedures..... | 30 | +| 5.5.1 General..... | 30 | +| 5.5.2 E2 Setup procedure..... | 30 | +| 5.5.3 Reset procedure ..... | 31 | +| 5.5.4 RIC Service Update procedure ..... | 33 | +| 5.5.4A RIC Service Query procedure..... | 34 | +| 5.5.5 E2 Node Configuration Update procedure..... | 34 | +| 5.5.6 E2 Removal procedure..... | 35 | +| 5.5.7 E2 Resource Status ..... | 36 | +| 5.5.8 E2 Resource Status Update..... | 37 | +| 6 E2 interface signalling..... | 37 | +| 6.1 E2 control plane protocol (E2AP) ..... | 37 | +| 6.2 Multiple TNLAs over E2 ..... | 38 | +| 7 Security for the E2 interface..... | 41 | +| 7.1 General ..... | 41 | +| 7.2 Requirements for the E2 interfaces ..... | 41 | +| 7.3 Security mechanism for the E2 interface..... | 41 | +| 8 Other E2 interface specifications ..... | 42 | +| 8.1 O-RAN E2 interface: E2 Application Protocol (E2AP) (ORAN-WG3.E2AP)..... | 42 | +| 8.2 O-RAN E2 interface: E2 Service Model (E2SM) specifications..... | 42 | +| Annex A (normative): Deployment considerations ..... | 43 | +| A.1 Deployment use cases ..... | 43 | + +| | | +|---------------------------------------|----| +| Annex B (informative): Change history | 45 | +|---------------------------------------|----| + +# List of figures + +| | | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----| +| Figure 4.2-1: O-RAN architecture overview showing Near-RT RIC interfaces ..... | 10 | +| Figure 5.1.2-1: Relationship between Near-RT RIC and E2 Node ..... | 12 | +| Figure 5.3.2.2-1: RIC Service REPORT ..... | 14 | +| Figure 5.3.2.3-1: RIC Service INSERT with subsequent RIC Service CONTROL responses ..... | 15 | +| Figure 5.3.2.4-1: RIC Service CONTROL as response to RIC Service INSERT ..... | 17 | +| Figure 5.3.2.4-2: RIC Service CONTROL initiated by NEAR-RT RIC ..... | 18 | +| Figure 5.3.2.5-1: RIC Service POLICY ..... | 19 | +| Figure 5.3.2.5A-1: RIC Service QUERY ..... | 20 | +| Figure 5.3.2.5B-1: RIC Service ASSISTANCE ..... | 21 | +| Figure 5.3.2.6-1: RIC Subscription, RIC Subscription Modification, RIC Subscription Delete, RIC Subscription Audit and RIC Subscription State Control procedures ..... | 26 | +| Figure 5.3.2.6-2: RIC Subscription Delete Required and RIC Subscription Delete procedures ..... | 27 | +| Figure 5.3.2.6-3: RIC Subscription Modification Required procedure ..... | 27 | +| Figure 5.3.2.6-4: RIC Service Load Status and RIC Service Load Update procedures ..... | 28 | +| Figure 5.5.2-1: E2 Setup procedure ..... | 31 | +| Figure 5.5.3-1: Reset procedure (E2 Node initiated) ..... | 32 | +| Figure 5.5.3-2: Reset procedure (Near-RT RIC initiated) ..... | 33 | +| Figure 5.5.4-1: RIC Service Update procedure ..... | 34 | +| Figure 5.5.4A-1: RIC Service Query procedure ..... | 34 | +| Figure 5.5.5-1: E2 Node Configuration Update procedure ..... | 35 | +| Figure 5.5.6-1: E2 Removal procedure (E2 Node initiated) ..... | 36 | +| Figure 5.5.6-2: E2 Removal procedure (Near-RT RIC initiated) ..... | 36 | +| Figure 5.5.7-1: E2 Resource Status procedure ..... | 36 | +| Figure 5.5.8-1: E2 Resource Status Update procedure ..... | 37 | +| Figure 6.1-1: E2AP protocol stack ..... | 38 | +| Figure 6.2-1: TNL management examples (E2 Setup and Near-RT RIC initiated TNL Addition) ..... | 39 | +| Figure 6.2-2: TNL management examples (Near-RT RIC initiated TNL Modification and TNL Removal) ..... | 40 | +| Figure 6.2-3: TNL management examples (E2 Node initiated TNL Addition and TNL Removal) ..... | 41 | +| Figure A.1-1: Example deployment use case with single E2 Node supporting both O-CU-CP and O-CU-UP roles ..... | 43 | +| Figure A.1-2: Example deployment use case with single E2 Node supporting O-CU-CP, O-CU-UP and O-DU roles ..... | 44 | + +# List of tables + +| | | +|--------------------------------------------------------------------------------------------------------------------------|----| +| Table 5.3.2.6-1A: Relationship between RIC Services and E2AP Procedures related to RIC Subscriptions ..... | 23 | +| Table 5.3.2.6-1B: Relationship between RIC Services and E2AP Procedures related to other RIC Functional procedures ..... | 24 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG3 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document describes the general aspects and principles of the E2 interface between Near-RT RIC and one or more E2 Nodes, including the interaction with applications hosted in the Near-RT RIC. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +The following referenced documents are necessary for the application of the present document. + +- | | | +|------|-----------------------------------------------------------------------------------------------------------| +| [1] | Void. | +| [2] | O-RAN WG3.TS.E2AP, "O-RAN E2 Application Protocol (E2AP)". | +| [3] | Void. | +| [4] | Void. | +| [5] | 3GPP TS 36.401: "Evolved Universal Terrestrial Radio Access Network (E-UTRAN); Architecture Description". | +| [6] | 3GPP TS 38.401: "NG-RAN; Architecture description". | +| [7] | Void. | +| [8] | Void. | +| [9] | Void. | +| [10] | Void. | +| [11] | Void. | +| [12] | IETF RFC 4960: "Stream Control Transmission Protocol". | +| [13] | Void. | +| [14] | Void. | +| [15] | Void. | +| [16] | 3GPP TS 38.300 NR; "NR and NG-RAN Overall Description; Stage 2". | +| [17] | O-RAN WG3.TS.E2SM; "O-RAN E2 Service Model (E2SM)". | +| [18] | O-RAN WG1.TS.OAD, "O-RAN Architecture Description". | +| [19] | Void. | +| [20] | IETF RFC 4303, "IP Encapsulating Security Payload (ESP)" | + +- [21] 3GPP TS 33.210: Technical Specification Group Services and System Aspects; Network Domain Security (NDS); IP network layer security +- [22] 3GPP TS 33.310: "Universal Mobile Telecommunications System (UMTS); LTE; 5G; Network Domain Security (NDS); Authentication Framework (AF)" +- [23] IETF RFC 6335, "Internet Assigned Numbers Authority (IANA) Procedures for the Management of the Service Name and Transport Protocol Port Number Registry" +- [24] Void. +- [25] 3GPP TS 36.300: "Evolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Universal Terrestrial Radio Access Network (E-UTRAN) " + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications" + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in 3GPP TR 21.905 [i.1], O-RAN WG1.TS.OAD [18] and the following apply: + +**E2 Service Model:** collection of E2AP IEs that are specified in O-RAN WG3.TS.E2AP [2] to have RAN Function specific definitions. + +**RAN Function:** specific functionality in a E2 Node that supports one or more RIC Services exposed by the E2 Node to the Near-RT RIC. + +**RIC Service:** service provided on an E2 Node or Near-RT RIC for use over the E2 interface. + +**SCTP association:** As defined in IETF RFC 4960 [12]. In the present document, SCTP association is interchangeably used by TNL (Transport Network Layer) association. + +**SCTP endpoint (or end-point):** As defined in IETF RFC 4960 [12]. + +## 3.2 Symbols + +Void. + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [i.1], O-RAN WG1.TS.OAD [18] and the following apply: + +| | | +|------|-------------------------| +| RAT | Radio Access Technology | +| TNL | Transport Network Layer | +| TNLA | TNL Association | + +# --- 4 E2 interface architecture + +## 4.1 General architecture principles + +The general principles guiding the definition of the E2 interface between Near-RT RIC and E2 Nodes are the following: + +- Near-RT RIC and E2 Node functions are fully separated from transport functions. Addressing scheme used in Near-RT RIC and the E2 Nodes shall not be tied to the addressing schemes of transport functions. +- The E2 Nodes support all protocol layers and interfaces defined within 3GPP radio access networks that include eNB for E-UTRAN, 3GPP TS 36.300 [25] and 3GPP TS 36.401 [5], and gNB/ ng-eNB for NG-RAN, 3GPP TS 38.300 [16] and 3GPP TS 38.401 [6]. +- Near-RT RIC may use the set of RIC Services that are exposed by an E2 Node. +- E2 Node may use the set of RIC Services that are exposed by the Near-RT RIC. +- The E2 Node shall describe the available RIC Services using a series of RAN function and Radio Access Technology (RAT) dependent "E2 Service Models". +- E2 interfaces are defined along the following principles: + - Interfaces are based on a logical model of the entity controlled through this interface. + - One physical network element can implement multiple logical nodes. + +## 4.2 O-RAN architecture considerations + +The Near-RT RIC and E2 Nodes connected by the E2 interface, as presented in Figure 4.2-1, are part of the overall O-RAN Architecture O-RAN WG1.TS.OAD [18]. + +![Figure 4.2-1: O-RAN architecture overview showing Near-RT RIC interfaces. The diagram illustrates the O-RAN architecture. At the top is the 'Near-RT RIC' block. Below it are three 'E2 Node' blocks: 'O-eNB' on the left, 'O-CU-CP' in the center, and 'O-CU-UP' on the right. The 'O-CU-CP' and 'O-CU-UP' blocks are connected to each other via an 'E1' interface. Below these is the 'O-DU' block, which is connected to 'O-CU-CP' via an 'F1-c' interface and to 'O-CU-UP' via an 'F1-u' interface. At the bottom is the 'O-RU' block, connected to 'O-DU' via an 'Open Fronthaul' interface. The 'Near-RT RIC' is connected to each of the 'E2 Node' blocks (O-eNB, O-CU-CP, O-CU-UP, and O-DU) via 'E2' interfaces.](41132cba2afc71ce3efd85e5aa3b458e_img.jpg) + +Figure 4.2-1: O-RAN architecture overview showing Near-RT RIC interfaces. The diagram illustrates the O-RAN architecture. At the top is the 'Near-RT RIC' block. Below it are three 'E2 Node' blocks: 'O-eNB' on the left, 'O-CU-CP' in the center, and 'O-CU-UP' on the right. The 'O-CU-CP' and 'O-CU-UP' blocks are connected to each other via an 'E1' interface. Below these is the 'O-DU' block, which is connected to 'O-CU-CP' via an 'F1-c' interface and to 'O-CU-UP' via an 'F1-u' interface. At the bottom is the 'O-RU' block, connected to 'O-DU' via an 'Open Fronthaul' interface. The 'Near-RT RIC' is connected to each of the 'E2 Node' blocks (O-eNB, O-CU-CP, O-CU-UP, and O-DU) via 'E2' interfaces. + +**Figure 4.2-1: O-RAN architecture overview showing Near-RT RIC interfaces** + +With respect to the E2 interface: + +- E2 is a logical interface connecting the Near-RT RIC with an E2 Node: + - The Near-RT RIC is connected to the O-CU-CP; + - The Near-RT RIC is connected to the O-CU-UP; + - The Near-RT RIC is connected to the O-DU; + - The Near-RT RIC is connected to the O-eNB. +- An E2 Node is connected to only one Near-RT RIC. +- A Near-RT RIC can be connected to multiple E2 Nodes, i.e. multiple O-CU-CPs, O-CU-UPs, O-DUs and O-eNBs. +- F1 (F1-C, F1-U) and E1 are logical 3GPP interfaces, whose protocols, termination points and cardinalities are specified in NG-RAN, 3GPP TS 38.401 [6]. + +The Near-RT RIC use E2 interface to collect near real-time information (e.g. UE basis, Cell basis) and provide value added services. + +The protocols over E2 interface are based exclusively on Control plane protocols and are defined in O-RAN WG3.TS.E2AP [2]. + +# --- 5 E2 interface + +## 5.1 E2 interface requirements and general principles + +### 5.1.1 E2 interface requirements + +The E2 interface shall support the following requirements: + +- E2 interface requirements and general principles shall comply with the general O-RAN architecture principles specified in O-RAN WG1.TS.OAD [18]. +- E2 interface shall uniquely identify each E2 Node configured to directly provide RIC Services to the Near-RT RIC. +- A given Near-RT RIC may support E2 connections from multiple E2 Nodes, each supporting a specific RAT type. +- E2 interface shall expose from the E2 Node a list of RAN Functions supporting RIC Services and the corresponding E2 Service Model. +- E2 interface shall allow the Near-RT RIC to address specific RAN Functions in a specific E2 Node. +- E2 node shall function independently of the Near-RT RIC when and if the E2 interface and/or Near-RT RIC fails. +- E2 interface shall support latency requirements for near-real-time optimization, i.e. from 10 milliseconds up to 1 second as specified in O-RAN WG1.TS.OAD [18]. +- RAN Functions supported over E2 interface shall be subject to the capability of the E2 Node exposed over the E2 interface by means of the E2 Service Model. +- E2 Service Model shall describe the RAN Functions in the E2 Node that may be optimized by the Near RT RIC. +- For a RAN Function exposed in the E2 Service Model, the Near-RT RIC may e.g. monitor, override or control via policies the behaviour of E2 node. + +### 5.1.2 E2 interface general principles + +The general principles for the specification of the E2 interface are as follows: + +- E2 interface is open; +- E2 interface supports the exchange of control signalling information between the endpoints; +- E2 is a point-to-point interface between the endpoints on Near-RT RIC and E2 Node; +- E2 interface definition supports interface management procedures based on principles from 3GPP RAN interfaces; +- E2 interface provides the capability to send predefined information towards the Near-RT RIC based on a pre-configured trigger event; +- E2 interface supports the ability to provide UE ID information towards the Near-RT RIC based on a pre-configured trigger event; +- E2 interface enables the Near-RT-RIC to direct the E2 Node to interrupt an associated procedure and forward the relevant information to the Near-RT RIC based on a pre-configured trigger event; +- E2 interface supports the ability to send control messages (e.g. UE basis, Cell basis) to the E2 Node; +- E2 interface supports the ability to provide the E2 Node with a set of policies to use when defined events occur; +- E2 interface supports the ability for E2 Node to inform the Near-RT RIC of what functionality it supports; +- E2 interface supports the ability to query the E2 Node for relevant RAN- and/or UE-related information; + +- E2 interface supports the ability for E2 node to consume services produced by the Near-RT RIC. + +With respect to the E2 interface, the E2 Node consists of: + +- Logical E2 Agent used to terminate the E2 interface, support global services and to forward/receive RIC service messages towards RAN Functions. +- One or more RAN Functions that support RIC services exposed by the E2 Node to the Near-RT RIC. +- Other RAN functions that do not support RIC Services. + +![Diagram showing the relationship between Near-RT RIC and E2 Node. The Near-RT RIC is connected to the E2 Node via the E2 interface. The E2 Node contains an E2 Agent, which is connected to RAN Func(1) through RAN Func(N), and Other functions.](781f21186364aa7d3214ce432735de65_img.jpg) + +``` + +graph TD + Near-RT RIC -- E2 --> E2 Node + subgraph E2 Node + E2 Agent + RAN_Func1[RAN Func(1)] + RAN_FuncN[RAN Func(N)] + Other_functions[Other functions] + E2 Agent --- RAN_Func1 + E2 Agent --- RAN_FuncN + end + +``` + +Diagram showing the relationship between Near-RT RIC and E2 Node. The Near-RT RIC is connected to the E2 Node via the E2 interface. The E2 Node contains an E2 Agent, which is connected to RAN Func(1) through RAN Func(N), and Other functions. + +**Figure 5.1.2-1: Relationship between Near-RT RIC and E2 Node** + +## 5.2 E2 interface specification objectives + +The E2 interface specifications shall facilitate the following: + +- Connectivity between Near-RT RIC and E2 Node supplied by different vendors; +- Exposure of selected E2 Node data (e.g. configuration information (cell configuration, supported slices, PLMNs, etc.), network measurements, context information, etc.) towards the Near-RT RIC; +- Enables the Near-RT RIC to control selected RAN functions on the E2 Node. + +## 5.3 Functions of the E2 interface + +### 5.3.1 General + +The E2 functions are grouped into the following categories: + +RIC services supported by RIC functional procedures: + +- RIC Services (**REPORT, INSERT, CONTROL, POLICY, QUERY** and **ASSISTANCE**), as described in clause 5.3.2) supported by RIC functional procedures (RIC Subscription, RIC Subscription Modification, RIC Subscription Modification Required, RIC Subscription Delete, RIC Subscription Delete Required, RIC Subscription Audit, RIC Subscription State Control, RIC Indication, RIC Control, RIC Query, RIC Service Load Status, RIC Service Load Update, RIC Assistance, RIC Assistance Indication, RIC Assistance Halt). + +Global procedures: + +- Interface Management procedures (E2 Setup, Reset, E2 Node Configuration Update, E2 connection Update, E2 Removal, E2 Resource Status, E2 Resource Status Update, Error Indication) +- RAN Function procedures (RIC Service Update, RIC Service Query). + +### 5.3.2 RIC services and related procedures + +#### 5.3.2.1 RIC services + +Near-RT RIC may use the following RIC services provided by an E2 node: + +- **REPORT**: Near-RT RIC uses a RIC Subscription and/or RIC Subscription Modification procedures to request that E2 Node sends a **REPORT** message to Near-RT RIC and the associated procedure continues in the E2 Node after each occurrence of a defined RIC Subscription procedure Event Trigger. +- **INSERT**: Near-RT RIC uses a RIC Subscription and/or RIC Subscription Modification procedures to request that E2 Node sends an **INSERT** message to Near-RT RIC after each occurrence of a defined RIC Subscription procedure Event Trigger. +- **CONTROL**: Near-RT RIC sends a **CONTROL** message to E2 Node to initiate a new associated procedure or resume an associated procedure in the E2 Node. +- **POLICY**: Near-RT RIC uses a RIC Subscription and/or RIC Subscription Modification procedures to request that E2 Node executes a specific **POLICY** during functioning of the E2 Node after each occurrence of a defined RIC Subscription procedure Event Trigger. +- **QUERY**: Near-RT RIC sends a **QUERY** message to the E2 node to retrieve RAN-related and/or UE-related information from the E2 Node. + +E2 Node may use the following RIC services provided by the Near-RT RIC: + +- **ASSISTANCE**: E2 Node sends an **ASSISTANCE** message to the Near-RT RIC to utilize a service offered by the Near-RT RIC. + +#### 5.3.2.2 REPORT service + +The **REPORT** service involves following steps: + +- 1) Near-RT RIC configures, and subsequently may modify, a RIC Subscription in the E2 Node with information for Indication (Report) that is to be sent by the E2 Node with each occurrence of RIC trigger event condition +- 2) During normal functioning of an associated procedure in the E2 Node, a RIC Event Trigger is detected. +- 3) After completing any previous RIC actions, E2 Node sends RIC INDICATION message to Near-RT RIC containing the requested **REPORT** information along with the originating Request ID. +- 4) Associated procedure continues in the E2 Node, including any subsequent RIC actions. + +![Sequence diagram for RIC Service REPORT showing interactions between Near-RT RIC and E2 Node.](c19b48699f086c1ac69ce3595f074e46_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Note over Near-RT RIC, E2 Node: 1) RIC Subscription procedure (RIC Event Trigger, Action=REPORT) + Note over Near-RT RIC, E2 Node: 1a) RIC Subscription Modification procedure + Note over E2 Node: 2) E2 Node detects RIC Event Trigger + Note over E2 Node: 4) Associated procedure continues + Note over Near-RT RIC, E2 Node: 3) RIC INDICATION (REPORT) + +``` + +The diagram illustrates the RIC Service REPORT process. It involves two main entities: Near-RT RIC and E2 Node. The process begins with the Near-RT RIC sending a '1) RIC Subscription procedure (RIC Event Trigger, Action=REPORT)' to the E2 Node. This is followed by a '1a) RIC Subscription Modification procedure' (indicated by a dashed line). The E2 Node then '2) E2 Node detects RIC Event Trigger'. A note '4) Associated procedure continues' is shown on the E2 Node's lifeline. Finally, the E2 Node sends a '3) RIC INDICATION (REPORT)' back to the Near-RT RIC. + +Sequence diagram for RIC Service REPORT showing interactions between Near-RT RIC and E2 Node. + +**Figure 5.3.2.2-1: RIC Service REPORT** + +#### 5.3.2.3 INSERT service + +The **INSERT** service involves following steps: + +- 1) Near-RT RIC configures, and subsequently may modify, a RIC Subscription in the E2 Node with information for an INSERT action, along with an associated Subsequent Action Information (Subsequent Action type, Time to Wait timer), that is to be performed by E2 Node with each occurrence of Event. +- 2) During normal functioning of an associated procedure in the E2 Node, a trigger event is detected. +- 3) After completing any previous RIC actions, E2 Node waits for the corresponding response for up to a defined Time to Wait period. +- 4) E2 Node sends RIC INDICATION message to Near-RT RIC containing the requested **INSERT** information along with the originating Request ID and information to identify the associated procedure. +- 5) According to the Time to Wait timer state, arrival of RIC CONTROL procedure, and Subsequent Action parameter in the RIC Subscription, the E2 Node may then: + - a) RIC CONTROL REQUEST message arrives in time: +This case is described in clause 5.3.2.4. + - b) The associated Time to Wait timer expires and Subsequent Action Type set to Continue: +Continue the original associated procedure, including any subsequent RIC actions, if and when the associated Time to Wait timer expires. If the Near-RT RIC subsequently sends a RIC CONTROL REQUEST message with the Call Process ID for the same associated procedure, then the E2 Node shall respond with the RIC CONTROL FAILURE message with a cause to indicate that the timer has expired. See also clause 5.3.2.4. + - c) The associated Time to Wait timer expires and Subsequent Action Type set to Halt: +Halt the original associated procedure, including any subsequent RIC actions, if and when the associated Time to Wait timer expires. If the Near-RT RIC subsequently sends a RIC CONTROL REQUEST message with the Call Process ID for the same associated procedure, then the E2 Node shall respond with the RIC CONTROL FAILURE message with a cause to indicate that the timer has expired. See also clause 5.3.2.4. + +![Sequence diagram showing RIC Service INSERT with subsequent RIC Service CONTROL responses between Near-RT RIC and E2 Node.](b2bb68c7cbd90703d1d55851c84edc77_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + + Note over Near-RT RIC, E2 Node: 1) RIC Subscription procedure (RIC Event Trigger, Action=INSERT) + Note over Near-RT RIC, E2 Node: 1a) RIC Subscription Modification procedure + Note over E2 Node: 2) E2 Node detects RIC Event Trigger + Note over E2 Node: 3) Associated procedure waits + Note over E2 Node: Start associated Time to Wait Timer + Note over E2 Node: 4) RIC INDICATION(INSERT) + alt [5a) Near-RT RIC responds in time] + Note over Near-RT RIC: Near-RT RIC performs action + Note over Near-RT RIC, E2 Node: 5a) RIC CONTROL REQUEST + Note over E2 Node: Handle request (see CONTROL service) + else [5b) Time to Wait timer Expires and Subsequent Action = Continue] + Note over E2 Node: Associated Time to Wait Timer expires + Note over E2 Node: Associated procedure resumes + Note over Near-RT RIC, E2 Node: 5b) RIC CONTROL REQUEST + Note over E2 Node: RIC CONTROL FAILURE (Cause=Control timer expired) + else [5c) Time to wait timer Expires and Subsequent Action = Halt] + Note over E2 Node: Associated Time to Wait Timer expires + Note over E2 Node: Associated procedure halted + Note over Near-RT RIC, E2 Node: 5c) RIC CONTROL REQUEST + Note over E2 Node: RIC CONTROL FAILURE (Cause=Control timer expired) + end + end + +``` + +The diagram illustrates the sequence of events for the RIC Service INSERT with subsequent RIC Service CONTROL responses. The participants are Near-RT RIC and E2 Node. + +- 1) RIC Subscription procedure (RIC Event Trigger, Action=INSERT)**: Near-RT RIC sends a message to E2 Node. +- 1a) RIC Subscription Modification procedure**: Near-RT RIC sends a message to E2 Node. +- 2) E2 Node detects RIC Event Trigger**: E2 Node performs an internal action. +- 3) Associated procedure waits**: E2 Node performs an internal action. +- Start associated Time to Wait Timer**: E2 Node performs an internal action. +- 4) RIC INDICATION(INSERT)**: E2 Node sends a message to Near-RT RIC. +- alt [5a) Near-RT RIC responds in time]**: + - Near-RT RIC performs action**: Near-RT RIC performs an internal action. + - 5a) RIC CONTROL REQUEST**: Near-RT RIC sends a message to E2 Node. + - Handle request (see CONTROL service)**: E2 Node performs an internal action. +- [5b) Time to Wait timer Expires and Subsequent Action = Continue]**: + - Associated Time to Wait Timer expires**: E2 Node performs an internal action. + - Associated procedure resumes**: E2 Node performs an internal action. + - 5b) RIC CONTROL REQUEST**: Near-RT RIC sends a message to E2 Node. + - RIC CONTROL FAILURE (Cause=Control timer expired)**: E2 Node sends a message to Near-RT RIC. +- [5c) Time to wait timer Expires and Subsequent Action = Halt]**: + - Associated Time to Wait Timer expires**: E2 Node performs an internal action. + - Associated procedure halted**: E2 Node performs an internal action. + - 5c) RIC CONTROL REQUEST**: Near-RT RIC sends a message to E2 Node. + - RIC CONTROL FAILURE (Cause=Control timer expired)**: E2 Node sends a message to Near-RT RIC. + +Sequence diagram showing RIC Service INSERT with subsequent RIC Service CONTROL responses between Near-RT RIC and E2 Node. + +Figure 5.3.2.3-1: RIC Service INSERT with subsequent RIC Service CONTROL responses + +#### 5.3.2.4 CONTROL service + +The **CONTROL** service involves following steps: + +Near-RT RIC detects an event trigger. This step may be triggered by either: + +- a) a previous RIC INDICATION message sent by E2 Node; + - b) internal to Near-RT RIC. +- 1) Near-RT RIC performs an action. + - 2) Near-RT RIC sends a RIC CONTROL REQUEST message to E2 Node. This message may contain information to identify the associated procedure, and may request acknowledgement from the E2 Node. The Near-RT RIC shall set the timer $T_{RICcontrol}$ if either acknowledgement has been requested or the optional acknowledgement request was not present in the RIC CONTROL REQUEST message. + - 3) The E2 Node cancels the associated Time to Wait timer if previously set, and initiates or resumes the associated procedure. + - 4) E2 Node then: + - i) If the requested control service is successfully executed, and if acknowledgement was requested or if the optional RIC Control Ack Request was not present, the E2 Node sends the RIC CONTROL ACKNOWLEDGE message with the optional RIC Control Outcome providing information about the result of the request Control service. + - ii) If the requested control service fails to execute or the request is not accepted, the E2 Node sends the RIC CONTROL FAILURE message with a cause indicating the reason for failure or rejection and the optional RIC Control outcome providing information about the reason for failure to execute. + - 5) If previously set, the Near-RT RIC shall cancel the $T_{RICcontrol}$ timer + +![Sequence diagram showing the RIC Service CONTROL procedure as a response to RIC Service INSERT between Near-RT RIC and E2 Node.](a4625b8d31b820d7b6c97d2dff80eb40_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + + Note over Near-RT RIC, E2 Node: RIC Subscription procedure (RIC Event Trigger, Action=INSERT) + Note over Near-RT RIC, E2 Node: RIC Subscription Modification procedure + Note over E2 Node: E2 Node detects RIC Event Trigger + Note over E2 Node: Associated procedure waits + Note over E2 Node: RIC INDICATION(INSERT) + Note over Near-RT RIC: 1) Near-RT RIC performs action + Note over Near-RT RIC, E2 Node: 2) RIC CONTROL REQUEST + Note over Near-RT RIC: Set Timer RIC control + Note over E2 Node: 3) Check request Call Process ID and associated Time to Wait timer + + alt [A] Request with Call Process ID received before associated Time to Wait timer expiry + alt [a] Request is accepted + Note over E2 Node: Cancel Wait Timer + Note over E2 Node: Associated procedure resumes + alt [i] E2 Node successfully executes requested control procedure and "ack" response requested + Note over E2 Node: 4 i) RIC CONTROL ACKNOWLEDGE + else [ii] E2 Node fails to execute requested control procedure and "nack" response requested + Note over E2 Node: 4 ii) RIC CONTROL FAILURE (Cause = Failure to execute) + end + else [b] Request is rejected + Note over E2 Node: 4 ii) RIC CONTROL FAILURE (Cause provides reason for rejection) + end + else [B] Request with Call Process ID received after associated Time to Wait timer expiry + Note over E2 Node: Associated procedure previously Halted or Continued + Note over E2 Node: 4 ii) RIC CONTROL FAILURE (Cause = Control timer expired ) + else [C] Request received with unknown Call Process ID + Note over E2 Node: 4 ii) RIC CONTROL FAILURE (Cause = Call process ID invalid) + end + + Note over Near-RT RIC: Clear Timer RIC control + +``` + +The diagram illustrates the RIC Service CONTROL procedure as a response to RIC Service INSERT. The process involves two main entities: Near-RT RIC and E2 Node. + +- Initial Setup:** The Near-RT RIC sends a RIC Subscription procedure (RIC Event Trigger, Action=INSERT) to the E2 Node. The E2 Node then sends a RIC Subscription Modification procedure back to the Near-RT RIC. +- Event Trigger:** The E2 Node detects a RIC Event Trigger, which starts an associated procedure that waits. +- Indication and Action:** The E2 Node sends a RIC INDICATION(INSERT) to the Near-RT RIC. The Near-RT RIC then performs action 1) Near-RT RIC performs action. +- Request and Timer:** The Near-RT RIC sends a RIC CONTROL REQUEST (action 2) to the E2 Node. The E2 Node then sets a timer for RIC control (action 3) and checks the request Call Process ID and associated Time to Wait timer. +- Conditional Execution:** + - [A] Request with Call Process ID received before associated Time to Wait timer expiry:** + - [a] Request is accepted:** The E2 Node cancels the wait timer, and the associated procedure resumes. + - [i] E2 Node successfully executes requested control procedure and "ack" response requested:** The E2 Node sends 4 i) RIC CONTROL ACKNOWLEDGE to the Near-RT RIC. + - [ii] E2 Node fails to execute requested control procedure and "nack" response requested:** The E2 Node sends 4 ii) RIC CONTROL FAILURE (Cause = Failure to execute) to the Near-RT RIC. + - [b] Request is rejected:** The E2 Node sends 4 ii) RIC CONTROL FAILURE (Cause provides reason for rejection) to the Near-RT RIC. + - [B] Request with Call Process ID received after associated Time to Wait timer expiry:** The E2 Node sends 4 ii) RIC CONTROL FAILURE (Cause = Control timer expired ) to the Near-RT RIC. The associated procedure is previously Halted or Continued. + - [C] Request received with unknown Call Process ID:** The E2 Node sends 4 ii) RIC CONTROL FAILURE (Cause = Call process ID invalid) to the Near-RT RIC. +- Final Step:** The Near-RT RIC clears the timer for RIC control. + +Sequence diagram showing the RIC Service CONTROL procedure as a response to RIC Service INSERT between Near-RT RIC and E2 Node. + +Figure 5.3.2.4-1: RIC Service CONTROL as response to RIC Service INSERT + +![Sequence diagram for RIC Service CONTROL initiated by NEAR-RT RIC](b71b0b905ce74aceb5e607475d8b0814_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + + Note left of Near-RT RIC: RIC internal event + Note left of Near-RT RIC: Near-RT RIC detects event trigger + Note left of Near-RT RIC: 1) Near-RT RIC performs action + Note left of Near-RT RIC: 2) RIC CONTROL REQUEST + Note left of Near-RT RIC: Set Timer RIC control + Note right of E2 Node: 3) Check request + alt [a] Request is accepted + Note right of E2 Node: Associated procedure initiated + alt [i] E2 Node successfully executes requested control procedure + Note left of E2 Node: 4 i) RIC CONTROL ACKNOWLEDGE + else [ii] E2 Node fails to execute requested control procedure + Note left of E2 Node: 4 ii) RIC CONTROL FAILURE (Cause = Failure to execute) + end + else [b] Request is rejected + Note left of E2 Node: 4 ii) RIC CONTROL FAILURE (Cause provides reason for rejection) + end + Note left of Near-RT RIC: Clear Timer RIC control + Note left of Near-RT RIC: Near-RT RIC + Note right of E2 Node: E2 Node + +``` + +The diagram illustrates the sequence of events for the RIC Service CONTROL initiated by the NEAR-RT RIC. The process begins with a RIC internal event at the Near-RT RIC, which detects an event trigger and performs an initial action. It then sends a RIC CONTROL REQUEST to the E2 Node. The E2 Node checks the request, and if accepted, initiates an associated procedure. Depending on whether the E2 Node successfully executes the requested control procedure or fails, it sends a RIC CONTROL ACKNOWLEDGE or a RIC CONTROL FAILURE message back to the Near-RT RIC. If the request is rejected, a failure message is also sent. Finally, the Near-RT RIC clears the timer and the process ends. + +Sequence diagram for RIC Service CONTROL initiated by NEAR-RT RIC + +Figure 5.3.2.4-2: RIC Service CONTROL initiated by NEAR-RT RIC + +#### 5.3.2.5 POLICY service + +The **POLICY** service involves following steps: + +- 1) Near-RT RIC configures, and subsequently may modify, a RIC Subscription in the E2 Node with information used to configure a **POLICY** that is to be performed by E2 Node with each occurrence of trigger event +- 2) During normal functioning of the E2 Node, a trigger event is detected. +- 3) After completing any previous RIC actions, E2 Node modifies ongoing call process according to information contained in the **POLICY** description statement +- 4) Associated procedure continues in the E2 Node, including any subsequent RIC actions. + +Note that if previously configured with a dedicated RIC Subscription, the E2 Node may send a REPORT used to provide information on the associated procedure outcome. See clause 5.3.2.2 for details. + +![Sequence diagram for RIC Service POLICY showing interactions between Near-RT RIC and E2 Node.](142e19b0b998f26887c55684260096fc_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + + Note over Near-RT RIC, E2 Node: RIC Subscription procedure (RIC Event Trigger, Action=REPORT) + Note over Near-RT RIC, E2 Node: 1) RIC Subscription procedure (RIC Event Trigger, Action=POLICY) + Note over Near-RT RIC, E2 Node: 1a) RIC Subscription Modification procedure + Note over E2 Node: 2) E2 Node detects RIC Event Trigger + Note over E2 Node: 3) E2 Node modifies ongoing process according to policy + Note over E2 Node: 4) Associated procedure continues + Note over Near-RT RIC, E2 Node: RIC INDICATION (Report) + +``` + +The diagram illustrates the RIC Service POLICY procedure. It shows two entities: Near-RT RIC and E2 Node. The procedure starts with a RIC Subscription procedure (RIC Event Trigger, Action=REPORT) and 1) RIC Subscription procedure (RIC Event Trigger, Action=POLICY) between the two entities. This is followed by 1a) RIC Subscription Modification procedure. Then, the E2 Node performs 2) E2 Node detects RIC Event Trigger, 3) E2 Node modifies ongoing process according to policy, and 4) Associated procedure continues. Finally, a RIC INDICATION (Report) is sent from the E2 Node to the Near-RT RIC. + +Sequence diagram for RIC Service POLICY showing interactions between Near-RT RIC and E2 Node. + +**Figure 5.3.2.5-1: RIC Service POLICY** + +#### 5.3.2.5A QUERY service + +The **QUERY** service involves following steps: + +- 1) Near-RT RIC determines need for RAN and/or UE-related information from the E2 node. +- 2) Near-RT RIC sends a RIC QUERY REQUEST message to E2 Node. This message contains the requested information that needs to be fetched from the E2 Node. The Near-RT RIC shall set the timer $T_{RICquery}$ awaiting response from the E2 node. +- 3) E2 node attempts to retrieve the requested information for the Near-RT RIC. +- 4) E2 Node then: + - i) If the E2 node successfully retrieves the requested information for the Near-RT RIC, then the E2 node sends the RIC QUERY RESPONSE message containing the desired information. + - ii) If the E2 node fails to handle the request or fails to retrieve the requested information for the Near-RT RIC, then the E2 node sends the RIC QUERY FAILURE message along with the cause for failure. + +![Sequence diagram for RIC Service QUERY showing interactions between Near-RT RIC and E2 Node.](e7fb35b6f8cd6b609e7cda9f00a94ce2_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + + Note over Near-RT RIC: 1) Near-RT RIC determines need for RAN- and/or UE-related information + Note over Near-RT RIC: Start associated Timer + Near-RT RIC->>E2 Node: 2) RIC QUERY REQUEST + Note over E2 Node: 3) E2 node attempts to retrieve the desired information + alt [a] E2 Node accepts request [ + Note over E2 Node: Requested information is retrieved + E2 Node->>Near-RT RIC: 4 i) RIC QUERY RESPONSE + ] + alt [b] E2 Node rejects request [ + Note over E2 Node: Request handling fails or Requested information is unavailable + E2 Node->>Near-RT RIC: 4 ii) RIC QUERY FAILURE (with cause) + ] + Note over Near-RT RIC: Clear associated Timer + +``` + +The diagram illustrates the RIC Service QUERY process. It begins with the Near-RT RIC determining the need for RAN- and/or UE-related information and starting an associated timer. It then sends a RIC QUERY REQUEST to the E2 Node. The E2 Node attempts to retrieve the desired information. An alternative (alt) block handles two scenarios: [a] E2 Node accepts request, where the requested information is retrieved and a RIC QUERY RESPONSE is sent back to the Near-RT RIC; and [b] E2 Node rejects request, where request handling fails or the requested information is unavailable, leading to a RIC QUERY FAILURE (with cause) being sent back to the Near-RT RIC. Finally, the Near-RT RIC clears the associated timer. + +Sequence diagram for RIC Service QUERY showing interactions between Near-RT RIC and E2 Node. + +Figure 5.3.2.5A-1: RIC Service QUERY + +#### 5.3.2.5B ASSISTANCE services + +The **ASSISTANCE** request/response service involves following steps: + +1. E2 Node determines need for RIC Assistance service from the Near-RT RIC. +2. E2 Node sends a RIC ASSISTANCE REQUEST message to Near-RT RIC. This message contains information about the service to be provided from the Near-RT RIC and may contain request for one or more subsequent updates. +3. Near-RT RIC attempts to provide the requested service for the E2 Node. +4. Near-RT RIC then: + - a. If the Near-RT RIC successfully provides the requested assistance service for the E2 Node, then the Near-RT RIC sends the RIC ASSISTANCE RESPONSE message containing the desired information. This step may require Near-RT RIC to fetch information from one or more E2 Nodes. + - b. If the Near-RT RIC fails to handle the request for the E2 Node, then the Near-RT RIC sends the RIC ASSISTANCE FAILURE message along with the cause for failure. + +5. If requested and if the Near-RT RIC may subsequently provide an updated assistance service for the E2 Node, then the Near-RT RIC sends one or more ASSISTANCE INDICATION message. This step may require Near-RT RIC to fetch information from one or more E2 Nodes. +6. E2 Node may send RIC ASSISTANCE HALT message to halt the subsequent updates of the requested assistance service + +![Sequence diagram for RIC Service ASSISTANCE showing interactions between Near-RT RIC, E2 Node, and Other E2 Nodes.](345e11b5b10680b0659eacd37c4fbaea_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + participant Other E2 Nodes + + Note over E2 Node: 1) E2 Node determines need for assistance from Near-RT RIC + E2 Node->>Near-RT RIC: 2) RIC ASSISTANCE REQUEST + Note over Near-RT RIC: 3) Near-RT RIC attempts to provide requested service + alt [a] Near-RT RIC accepts request + Note over Near-RT RIC: Requested service is provided + Note over Near-RT RIC: Fetch information + Note over E2 Node: Fetch information + Note over Other E2 Nodes: Fetch information + Near-RT RIC->>E2 Node: 4 i) RIC ASSISTANCE RESPONSE + loop [If updates requested until number of requested updates have been provided or E2 Node requests that updates are to be halted] + Note over Near-RT RIC: Updated assistance is provided + Note over Near-RT RIC: Fetch information + Note over E2 Node: Fetch information + Note over Other E2 Nodes: Fetch information + Near-RT RIC->>E2 Node: 5) RIC ASSISTANCE INDICATION + Note over E2 Node: 6) RIC ASSISTANCE HALT + end + else [b] Near-RT RIC rejects request + Note over Near-RT RIC: Requested assistance handling fails + Near-RT RIC->>E2 Node: 4 ii) RIC ASSISTANCE FAILURE (with cause) + end + +``` + +The diagram illustrates the RIC Service ASSISTANCE process. It involves three main entities: Near-RT RIC, E2 Node, and Other E2 Nodes. The process begins with the E2 Node determining the need for assistance from the Near-RT RIC (Step 1). The E2 Node then sends a RIC ASSISTANCE REQUEST to the Near-RT RIC (Step 2). The Near-RT RIC attempts to provide the requested service (Step 3). An alternative path (alt) exists: if the Near-RT RIC accepts the request, it provides the requested service and fetches information from the E2 Node and Other E2 Nodes. It then sends a RIC ASSISTANCE RESPONSE (4 i) to the E2 Node. A loop follows, where the Near-RT RIC provides updated assistance, fetches information from the E2 Node and Other E2 Nodes, and sends a RIC ASSISTANCE INDICATION (5) to the E2 Node. The loop continues until the number of requested updates have been provided or the E2 Node requests that updates be halted. The E2 Node then sends a RIC ASSISTANCE HALT (6) to the Near-RT RIC. If the Near-RT RIC rejects the request (alt path b), the requested assistance handling fails, and the Near-RT RIC sends a RIC ASSISTANCE FAILURE (with cause) (4 ii) to the E2 Node. + +Sequence diagram for RIC Service ASSISTANCE showing interactions between Near-RT RIC, E2 Node, and Other E2 Nodes. + +Figure 5.3.2.5B-1: RIC Service ASSISTANCE + +#### 5.3.2.6 RIC service realization and relationship with E2AP procedures + +The RIC Services may be realized using the following RIC Functional procedures: + +RIC Subscription procedure (Near-RT RIC initiated) + +- Used to install Event Trigger and associated sequence of Actions corresponding to one or more RIC services **REPORT**, **INSERT** and/or **POLICY** + +RIC Subscription Modification procedure (Near-RT RIC initiated) + +- Used to modify Event Trigger and/or add, modify and/or remove associated sequence of Actions corresponding to one or more RIC services **REPORT**, **INSERT** and/or **POLICY** + +RIC Subscription Modification Required procedure (E2 Node initiated) + +- Used to request modification and/or removal of associated sequence of Actions corresponding to one or more RIC services **REPORT**, **INSERT** and/or **POLICY** + +RIC Subscription Delete procedure (Near-RT RIC initiated) + +- Used to delete previously installed RIC Subscription + +RIC Subscription Delete Required procedure (E2 Node initiated) + +- Used to indicate that one or more previously installed RIC Subscriptions are required to be deleted + +RIC Subscription Audit procedure (Near-RT RIC initiated) + +- Used to audit list of previously installed RIC Subscriptions + +RIC Subscription State Control procedure (Near-RT RIC initiated) + +- Used to suspend and/or resume a list of previously installed RIC Subscriptions + +RIC Indication procedure (E2 Node initiated) + +- Used to carry outcome of RIC services **REPORT** and **INSERT** + +RIC Control procedure (Near-RT RIC initiated) + +- Used to initiate RIC service **CONTROL** + +RIC Query procedure (Near-RT RIC initiated) + +- Used to request RAN and/or UE related information from E2 Node + +RIC Service Load Status procedure (Near-RT RIC initiated) + +- Used to request that E2 Node reports RIC Service level load updates + +RIC Service Load Update procedure (E2 Node initiated) + +- Used to report load status information for one or more RIC services + +The relationship between RIC Services and E2AP procedures related to RIC Subscription is presented in table 5.3.2.6-1A and the relationship between RIC Services and other E2AP procedures is presented in table 5.3.2.6-1B. + +**Table 5.3.2.6-1A: Relationship between RIC Services and E2AP Procedures related to RIC Subscriptions** + +| E2AP Procedure | RIC Service | | | +|-----------------------------------------------|--------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------| +| | REPORT | INSERT | POLICY | +| <b>RIC Subscription</b> | Installs one or more REPORT Services associated with a RIC Subscription | Installs one or more INSERT Services associated with a RIC Subscription | Installs one or more POLICY Services associated with a RIC Subscription | +| <b>RIC Subscription Modification</b> | Adds, Modifies and/or Removes one or more REPORT Services associated with a RIC Subscription | Adds, Modifies and/or Removes one or more INSERT Services associated with a RIC Subscription | Adds, Modifies and/or Removes one or more POLICY Services associated with a RIC Subscription | +| <b>RIC Subscription Modification Required</b> | Requests Modification and/or Removal of one or more REPORT Services associated with a RIC Subscription | Requests Modification and/or Removal of one or more INSERT Services associated with a RIC Subscription | Requests Modification and/or Removal of one or more POLICY Services associated with a RIC Subscription | +| <b>RIC Subscription Delete</b> | Deletes all REPORT Services associated with one or more RIC Subscriptions | Deletes all INSERT Services associated with one or more RIC Subscriptions | Deletes all POLICY Service associated with one or more RIC Subscriptions | +| <b>RIC Subscription Delete Required</b> | Requests Near-RT RIC to delete all REPORT Services associated with one or more RIC Subscriptions | Requests Near-RT RIC to delete all INSERT Services associated with one or more RIC Subscriptions | Requests Near-RT RIC to delete all POLICY Services associated with one or more RIC Subscriptions | +| <b>RIC Subscription State Control</b> | Suspends and/or Resumes one or more REPORT Services associated with one or more RIC Subscriptions | Suspends and/or Resumes one or more INSERT Services associated with one or more RIC Subscriptions | Suspends and/or Resumes one or more POLICY Services associated with one or more RIC Subscriptions | +| <b>RIC Subscription Audit</b> | Audits list of established RIC Subscriptions | | | + +**Table 5.3.2.6-1B: Relationship between RIC Services and E2AP Procedures related to other RIC Functional procedures** + +| E2AP Procedure | RIC Service | | | | | +|--------------------------------|-----------------------------------------------|-----------------------------------------------|------------------------------------------------|-----------------------------------------------|----------------------------------------------| +| | REPORT | INSERT | CONTROL | POLICY | QUERY | +| <b>RIC Indication</b> | Carries outcome of REPORT Service | Carries outcome of INSERT Service | | | | +| <b>RIC Control</b> | | | Initiates CONTROL Service | | | +| <b>RIC Query</b> | | | | | Initiates QUERY service | +| <b>RIC Service Load Status</b> | Initiates reporting on load of REPORT service | Initiates reporting on load of INSERT service | Initiates reporting on load of CONTROL service | Initiates reporting on load of POLICY service | Initiates reporting on load of QUERY service | +| <b>RIC Service Load Update</b> | Carries information on load of REPORT service | Carries information on load of INSERT service | Carries information on load of CONTROL service | Carries information on load of POLICY service | Carries information on load of QUERY service | + +The RIC Subscription, RIC Subscription Modification, RIC Subscription Modification Required, RIC Subscription Delete, and RIC Subscription Delete Required procedures are used to establish, modify or delete RIC subscriptions on the E2 Node. The RIC Subscription State Control procedure is used to suspend and/or resume one or more RIC Subscriptions. The RIC Subscription Audit procedure is used to audit the list of established RIC Subscriptions. + +The RIC Subscription, RIC Subscription Modification, RIC Subscription Delete, RIC Subscription Audit and RIC Subscription State Control procedures are initiated by the Near-RT RIC (Figure 5.3.2.6-1). In addition, the E2 Node may initiate a RIC Subscription Delete Required procedure to request removal of one or more existing RIC Subscriptions (Figure 5.3.2.6-2) and a + +RIC Subscription Modification Required procedure to request the modification or removal of one or more existing RIC services within an existing RIC Subscription (Figure 5.3.2.6-3). + +RIC Service Load Update procedure is used by the E2 Node to report the RIC Service load information related to one or more RIC Services. These reports shall be sent by the E2 Node if requested by the Near-RT RIC using the RIC Service Load Status procedure (Figure 5.3.2.6-4). + +![Sequence diagram showing RIC Subscription, Modification, Delete, Audit, and State Control procedures between Near-RT RIC and E2 Node.](2102608ef99c843aead1d53ffd6d7e49_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + + Note left of Near-RT RIC: Near-RT RIC determines need to create a new RIC Subscription + Note over Near-RT RIC, E2 Node: RIC Subscription procedure (RIC Request ID, RAN Function ID, RIC Event Trigger, Action list) + Note left of Near-RT RIC: Near-RT RIC may determine need to modify existing RIC Subscription + Note over Near-RT RIC, E2 Node: RIC Subscription Modification procedure (RIC Request ID, RAN Function ID, RIC Event Trigger, Actions to be removed list, Actions to be modified list, Actions to be added list) + Note right of E2 Node: E2 Node detects RIC Event Trigger + loop [For each Action in Action List] + Note right of E2 Node: E2 Node executes action + Note over Near-RT RIC, E2 Node: RIC Indication procedure (RIC Request ID, RAN Function ID, contents) + Note over Near-RT RIC, E2 Node: RIC Control procedure + end + Note left of Near-RT RIC: Near-RT RIC determines need to delete an existing RIC Subscription + Note over Near-RT RIC, E2 Node: RIC Subscription Delete procedure (RIC Request ID, RAN Function ID) + Note left of Near-RT RIC: Near-RT RIC determines need to audit existing RIC Subscriptions + Note over Near-RT RIC, E2 Node: RIC Subscription Audit procedure + Note left of Near-RT RIC: Near-RT RIC may determine need to initiate one or more procedures to correct detected inconsistencies + Note over Near-RT RIC, E2 Node: One or more RIC subscription related procedures + Note left of Near-RT RIC: Near-RT RIC may determine need to suspend and/or resume a list of RIC Subscriptions + Note over Near-RT RIC, E2 Node: RIC Subscription State Control procedure (List of RIC Subscriptions to be suspended, List of RIC Subscriptions to be resumed) + +``` + +The diagram illustrates the following procedures between the Near-RT RIC and the E2 Node: + +- RIC Subscription procedure:** Initiated by the Near-RT RIC, sending (RIC Request ID, RAN Function ID, RIC Event Trigger, Action list) to the E2 Node. +- RIC Subscription Modification procedure:** Initiated by the Near-RT RIC, sending (RIC Request ID, RAN Function ID, RIC Event Trigger, Actions to be removed list, Actions to be modified list, Actions to be added list) to the E2 Node. +- RIC Event Trigger:** Detected by the E2 Node. +- RIC Indication procedure:** Executed by the E2 Node for each action in the list, sending (RIC Request ID, RAN Function ID, contents) to the Near-RT RIC. +- RIC Control procedure:** Executed by the Near-RT RIC for each action in the list. +- RIC Subscription Delete procedure:** Initiated by the Near-RT RIC, sending (RIC Request ID, RAN Function ID) to the E2 Node. +- RIC Subscription Audit procedure:** Initiated by the Near-RT RIC, sending a request to the E2 Node. +- One or more RIC subscription related procedures:** Initiated by the Near-RT RIC, sending a request to the E2 Node. +- RIC Subscription State Control procedure:** Initiated by the Near-RT RIC, sending (List of RIC Subscriptions to be suspended, List of RIC Subscriptions to be resumed) to the E2 Node. + +Sequence diagram showing RIC Subscription, Modification, Delete, Audit, and State Control procedures between Near-RT RIC and E2 Node. + +**Figure 5.3.2.6-1: RIC Subscription, RIC Subscription Modification, RIC Subscription Delete, RIC Subscription Audit and RIC Subscription State Control procedures** + +![Sequence diagram for RIC Subscription Delete Required and RIC Subscription Delete procedures](2c389d82f021e3a8c3a836d8cb465c6f_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + + Note over Near-RT RIC, E2 Node: RIC Subscription procedure +(RIC Request ID#1, RAN Function ID#1, RIC Event Trigger, Action list) + Note over Near-RT RIC, E2 Node: RIC Subscription procedure +(RIC Request ID#n, RAN Function ID#n, RIC Event Trigger, Action list,...) + Note right of E2 Node: E2 Node needs to remove +one or more RIC Subscriptions + Note over Near-RT RIC, E2 Node: RIC Subscription Delete Required (List of RIC Request ID, RAN Function ID) + loop [For each RIC Subscription in the List] + Note left of Near-RT RIC: Near-RT RIC determines, if required, +RIC Subscription removal is acceptable + Note over Near-RT RIC, E2 Node: RIC Subscription Delete procedure (RIC Request ID, RAN Function ID) + end + +``` + +The diagram illustrates the RIC Subscription Delete Required and RIC Subscription Delete procedures between the Near-RT RIC and the E2 Node. The process begins with the E2 Node sending a RIC Subscription procedure (RIC Request ID#1, RAN Function ID#1, RIC Event Trigger, Action list) to the Near-RT RIC. This is followed by another RIC Subscription procedure (RIC Request ID#n, RAN Function ID#n, RIC Event Trigger, Action list,...). A note indicates that the E2 Node needs to remove one or more RIC Subscriptions. The E2 Node then sends a RIC Subscription Delete Required (List of RIC Request ID, RAN Function ID) to the Near-RT RIC. A loop is entered for each RIC Subscription in the List. Inside the loop, the Near-RT RIC determines if removal is acceptable, and then sends a RIC Subscription Delete procedure (RIC Request ID, RAN Function ID) to the E2 Node. + +Sequence diagram for RIC Subscription Delete Required and RIC Subscription Delete procedures + +Figure 5.3.2.6-2: RIC Subscription Delete Required and RIC Subscription Delete procedures + +![Sequence diagram for RIC Subscription Modification Required procedure](6983a15c6166761930f3be4fc7311d8b_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + + Note over Near-RT RIC, E2 Node: RIC Subscription procedure +(RIC Request ID, RAN Function ID, RIC Event Trigger, Action list) + Note right of E2 Node: E2 Node determines needs to modify and/or remove +one or more RIC actions in an existing RIC Subscription + Note over Near-RT RIC, E2 Node: RIC Subscription Modification Required procedure +(RIC Request ID, RAN Function ID, Actions required to be modified list, +Actions required to be removed list) + +``` + +The diagram illustrates the RIC Subscription Modification Required procedure between the Near-RT RIC and the E2 Node. The process begins with the E2 Node sending a RIC Subscription procedure (RIC Request ID, RAN Function ID, RIC Event Trigger, Action list) to the Near-RT RIC. A note indicates that the E2 Node determines needs to modify and/or remove one or more RIC actions in an existing RIC Subscription. The E2 Node then sends a RIC Subscription Modification Required procedure (RIC Request ID, RAN Function ID, Actions required to be modified list, Actions required to be removed list) to the Near-RT RIC. + +Sequence diagram for RIC Subscription Modification Required procedure + +Figure 5.3.2.6-3: RIC Subscription Modification Required procedure + +![Sequence diagram showing RIC Service Load Status and RIC Service Load Update procedures between Near-RT RIC and E2 Node.](c851a1825b11664b44eb7bf4dd486f40_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Note over Near-RT RIC, E2 Node: RIC Subscription procedure +(RIC Request ID#1, RAN Function ID#1, RIC Event Trigger, Action list) + Note over Near-RT RIC, E2 Node: RIC Subscription procedure +(RIC Request ID#n, RAN Function ID#n, RIC Event Trigger, Action list,...) + Note over Near-RT RIC, E2 Node: RIC Service Load Status procedure + loop [Periodic update] + Note over E2 Node: E2 Node measures load status +concerning one or more RIC Services + Note over Near-RT RIC, E2 Node: RIC Service Load Update procedure (load information) + end + +``` + +The diagram illustrates the interaction between a Near-RT RIC and an E2 Node for RIC Service Load Status and Update procedures. The process begins with a RIC Subscription procedure, where the E2 Node sends a message to the Near-RT RIC containing a RIC Request ID, RAN Function ID, RIC Event Trigger, and an Action list. This is followed by another RIC Subscription procedure with a different set of parameters. The RIC Service Load Status procedure is then initiated. A loop labeled '[Periodic update]' follows, where the E2 Node measures the load status concerning one or more RIC Services and sends a RIC Service Load Update procedure (load information) back to the Near-RT RIC. + +Sequence diagram showing RIC Service Load Status and RIC Service Load Update procedures between Near-RT RIC and E2 Node. + +Figure 5.3.2.6-4: RIC Service Load Status and RIC Service Load Update procedures + +### 5.3.3 Combining RIC services within a common RIC Subscription + +RIC services defined in clause 5.3.2 may be combined within a common Subscription with each RIC Service implemented as part of a sequence of Actions. + +Where appropriate in these cases, successive **REPORT** or **INSERT** messages sent to Near-RT RIC under the same subscription event trigger would contain the same assigned Subscription Request identifier, the same optional sequence number and each message with the unique assigned Action identifier. + +Examples include: + +- **POLICY** then **REPORT**. In this case, at each occurrence of the defined Event Trigger, the E2 Node would be instructed to first execute a defined POLICY and then send a defined REPORT message +- **REPORT** then **REPORT**. In this case, at each occurrence of the defined Event Trigger, the E2 Node would be instructed to first send a defined REPORT message to be followed by a second defined REPORT message containing normally different information. + +When more than one RIC service action has been accepted by the E2 Node then actions shall be executed as specified in O-RAN WG3.TS.E2AP [2]. + +### 5.3.4 Combining RIC services as a sequence of RIC services + +RIC services defined in clause 5.3.2 may be combined using a sequence of different RIC services implemented using a procedure executed within the Near-RT RIC. + +Examples include: + +- **REPORT** followed by **POLICY**. In this case, at each occurrence of the defined Event Trigger, the E2 Node would be instructed to send a defined **REPORT** message. The Near-RT RIC would use the information from one or more successive **REPORT** messages as input to a procedure that may result in a change or establishment of a RIC **POLICY** service. +- **INSERT** followed by **CONTROL**. In this case, at each occurrence of the defined Event Trigger, the E2 Node would be instructed to send a defined **INSERT** message containing information used to identify the associated procedure and then the Near-RT RIC would send a corresponding **CONTROL** message containing information used to identify a previous suspended associated procedure. +- **REPORT** followed by **CONTROL**. In this case, at each occurrence of the defined Event Trigger, the E2 Node would be instructed to send a defined **REPORT** message. The Near-RT RIC would use the information from one or more successive **REPORT** messages as input to a procedure that may result in a RIC **CONTROL** service message being sent to initiate an associated procedure in the E2 Node. + +## 5.4 RAN Function E2 Service Model + +As described in clause 5.1 the E2 interface is used to carry messages between a given E2 Node and Near-RT RIC. These messages may contain RAN Function specific content which is described in the corresponding RAN Function specific E2 Service Model. + +Each RAN Function is described in the following terms: + +- *RAN Function Definition*. Defines the RAN Function Name and describes the RIC Services that the specific RAN Function is currently configured to present over the E2 interface. +- *RIC Event Trigger Definition* approach. Describes the approach to be used in RIC Subscription and RIC Subscription Modification procedures to set or modify the RIC Event Trigger Definition in the RAN Function for RIC Services **REPORT**, **INSERT** and/or **POLICY**. +- *RIC Action Definition* approach. Describes the approach to be used in RIC Subscription and RIC Subscription Modification procedures to set or modify the required sequence of RIC Action in the RAN Function for RIC Services **REPORT**, **INSERT** and/or **POLICY**. +- *RIC Indication Header* and *RIC Indication Message* approach. Describes the approach to be used in RIC Indication procedure for RIC Services **REPORT** and **INSERT**. +- *RIC Control Header* and *RIC Control Message* approach. Describes the approach to be used in RIC Control procedure for RIC Service **CONTROL**. +- *RIC Call Process ID* approach. Describes the approach to be used by the E2 node in RIC Indication procedure for RIC Service **INSERT**. The same IE is used in the subsequent RIC Control procedure for RIC Service **CONTROL**. +- *RIC Control Outcome* approach. Describes the approach to be used by the E2 node in RIC Control procedure for RIC service **CONTROL**. +- RAN Function Policies. Describes the set of policies that the RAN Function is configured to support and the corresponding Parameters that may be used to configure the policy using RIC Service **POLICY**. +- *RIC Query Header* and *RIC Query Definition* approach. Describes the approach to be used by the Near-RT RIC in RIC Query procedure for RIC Service **QUERY**. +- *RIC Query Outcome* approach. Describes the approach to be used by the E2 node in RIC Query procedure for RIC Service **QUERY**. +- *RIC Assistance Header* and *RIC Assistance Message* approach. Describes the approach to be used in RIC Assistance procedure for RIC Service **ASSISTANCE**. + +- *RIC Assistance Outcome* approach. Describes the approach to be used by the Near-RT RIC in RIC Assistance procedure for RIC Service **ASSISTANCE**. +- *Service Level Cause* approach. Describes the approach to be used across all RIC Functional procedures for reporting service level faults. + +## 5.5 Global procedures + +### 5.5.1 General + +The E2 interface supports the following global procedures: + +- E2 Setup +- Reset +- Error Indication +- RIC Service Update +- RIC Service Query +- E2 Node Configuration Update +- E2 Connection Update +- E2 Removal +- E2 Resource Status +- E2 Resource Status Update + +The E2 Setup, Reset, RIC Service Update, RIC Service Query, E2 Node Configuration Update, E2 Removal, E2 Resource Status and E2 Resource Status Procedure procedures are described in further details in the following clauses. E2 Connection Update is described in clause 6.2. + +### 5.5.2 E2 Setup procedure + +The E2 Setup procedure is used to establish the E2 interface between the Near-RT RIC and an E2 Node. During this procedure the E2 Node provides: + +- List of supported RIC services and mapping of services to functions within the E2 Node. This information is specific to each RAN Function in the E2 node and is defined by a specific E2 Service Model as described in clause 5.4 +- List of E2 Node configuration information. The configuration information is specific to the E2 Node type (see clause 4.2) and based on the re-use of 3GPP RAN3 defined configuration update messages. + +If the E2 Setup procedure fails, the Near-RT RIC may provide an alternative Transport Layer Information for the E2 Node to use when reinitiating the E2 Setup procedure. + +![Sequence diagram of E2 Setup procedure between Near-RT RIC and E2 Node.](e8128caf2db01d603f0db227577ce583_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Note over E2 Node: E2 Node preconfigured with Near-RT RIC address and RIC service information and E2 node configuration + Near-RT RIC-->>E2 Node: Sctp connection establishment + E2 Node-->>Near-RT RIC: E2 SETUP REQUEST (RIC service and E2 Node configuration information) + Note over Near-RT RIC: Near-RT RIC extracts list of supported RIC Services and mapping of services to functions and stores information + Note over Near-RT RIC: Near-RT RIC extracts list of E2 Node configuration information and stores information + Near-RT RIC-->>E2 Node: E2 SETUP RESPONSE (RIC Service and E2 Node configuration Ack) + +``` + +The diagram illustrates the E2 Setup procedure between a Near-RT RIC and an E2 Node. The process begins with the E2 Node being preconfigured with the Near-RT RIC address, RIC service information, and E2 node configuration. The Near-RT RIC initiates the connection by sending an Sctp connection establishment message to the E2 Node. The E2 Node then sends an E2 SETUP REQUEST (containing RIC service and E2 Node configuration information) to the Near-RT RIC. The Near-RT RIC processes this request by extracting a list of supported RIC Services and mapping them to functions, storing this information. It also extracts a list of E2 Node configuration information and stores it. Finally, the Near-RT RIC sends an E2 SETUP RESPONSE (containing RIC Service and E2 Node configuration Ack) back to the E2 Node. + +Sequence diagram of E2 Setup procedure between Near-RT RIC and E2 Node. + +**Figure 5.5.2-1: E2 Setup procedure** + +### 5.5.3 Reset procedure + +The Reset procedure is used by either the E2 Node or Near-RT RIC to reset the E2 interface. + +Information previously exchanged during E2 Setup, E2 Node Configuration Update and RIC Service Update procedures shall be maintained however the outcome of all previous RIC Subscription shall be deleted from the E2 Node and E2 Node gracefully terminates any ongoing RIC Services. + +The Near-RT RIC may then proceed to re-establish any RIC Subscriptions as required. + +![Sequence diagram showing the Reset procedure initiated by the E2 Node. The process starts with the E2 Node detecting an abnormal failure, sending a RESET REQUEST (Cause) to the Near-RT RIC, which then informs xApps. The E2 Node also deletes pre-established subscriptions and terminates ongoing services. The Near-RT RIC sends a RESET RESPONSE back to the E2 Node and may re-establish subscriptions.](d932e28bdc9d91f907587cce9b49fd23_img.jpg) + +``` + +sequenceDiagram + participant Near-RT_RIC as Near-RT RIC + participant E2_Node as E2 Node + + Note over E2_Node: E2 Node detects abnormal failure + E2_Node->>Near-RT_RIC: RESET REQUEST (Cause) + Note over Near-RT_RIC: Near-RT RIC informs xApps of RESET from E2 Node + Note over E2_Node: E2 Node deletes any pre-established RIC Subscriptions + Note over E2_Node: E2 Node gracefully terminates any ongoing RIC Services + Near-RT_RIC->>E2_Node: RESET RESPONSE + Note over Near-RT_RIC: Near-RT RIC may re-establish RIC Subscriptions + +``` + +Sequence diagram showing the Reset procedure initiated by the E2 Node. The process starts with the E2 Node detecting an abnormal failure, sending a RESET REQUEST (Cause) to the Near-RT RIC, which then informs xApps. The E2 Node also deletes pre-established subscriptions and terminates ongoing services. The Near-RT RIC sends a RESET RESPONSE back to the E2 Node and may re-establish subscriptions. + +**Figure 5.5.3-1: Reset procedure (E2 Node initiated)** + +![Sequence diagram for Reset procedure (Near-RT RIC initiated)](e1489ee09b106f99d7a4b88a4b8de33b_img.jpg) + +``` + +sequenceDiagram + participant Near-RT_RIC as Near-RT RIC + participant E2_Node as E2 Node + + Note over Near-RT_RIC: Near-RT RIC detects abnormal failure + Note over Near-RT_RIC: RESET REQUEST (Cause) + Note over E2_Node: E2 Node deletes any pre-established RIC Subscriptions + Note over E2_Node: E2 Node gracefully terminates any ongoing RIC Services + Note over E2_Node: RESET RESPONSE + Note over Near-RT_RIC: Near-RT RIC informs xApps of RESET from E2 Node + Note over Near-RT_RIC: Near-RT RIC may re-establish RIC Subscriptions + +``` + +The diagram illustrates the reset procedure initiated by the Near-RT RIC. It shows the flow of messages and actions between the Near-RT RIC and the E2 Node. The process starts with the Near-RT RIC detecting an abnormal failure and sending a RESET REQUEST (Cause) to the E2 Node. The E2 Node then deletes any pre-established RIC Subscriptions and gracefully terminates any ongoing RIC Services. The E2 Node sends a RESET RESPONSE back to the Near-RT RIC, which then informs xApps of the RESET from the E2 Node and may re-establish RIC Subscriptions. + +Sequence diagram for Reset procedure (Near-RT RIC initiated) + +Figure 5.5.3-2: Reset procedure (Near-RT RIC initiated) + +### 5.5.4 RIC Service Update procedure + +The RIC Service Update procedure is used by the E2 Node to inform the Near-RT RIC of any change to the list of supported RIC services and mapping of services to functions within the E2 Node. This information is specific to each RAN Function in the E2 node and is defined by a specific E2 Service Model as described in clause 5.4. + +![Sequence diagram for RIC Service Update procedure](d6158143a2ac9f97ed9822c4b534445d_img.jpg) + +``` + +sequenceDiagram + participant Near-RT_RIC as Near-RT RIC + participant E2_Node as E2 Node + + Note over E2_Node: Change to RIC service configuration on E2 Node + Note over E2_Node: RIC SERVICE UPDATE (RIC service information) + Note over Near-RT_RIC: Near-RT RIC extracts list of changes to supported RIC Services including mapping of services to functions and updates stored information + Note over E2_Node: RIC SERVICE UPDATE ACKNOWLEDGE (RIC Service Ack) + +``` + +The diagram illustrates the RIC Service Update procedure. It shows the flow of messages and actions between the Near-RT RIC and the E2 Node. The process starts with the E2 Node sending a RIC SERVICE UPDATE (RIC service information) to the Near-RT RIC. The Near-RT RIC then extracts the list of changes to supported RIC Services, including the mapping of services to functions, and updates its stored information. Finally, the Near-RT RIC sends a RIC SERVICE UPDATE ACKNOWLEDGE (RIC Service Ack) back to the E2 Node. + +Sequence diagram for RIC Service Update procedure + +**Figure 5.5.4-1: RIC Service Update procedure** + +### 5.5.4A RIC Service Query procedure + +The RIC Service Query procedure is used by the Near-RT RIC to query the E2 Node with respect to the current list of supported RIC Services. The query procedure may be used to either request a complete list of supported RIC services or to request that the E2 Node compares the list of RIC Services provided in the query message with its current list of supported RIC Services. + +This procedure is initiated by the Near-RT RIC sending a RIC SERVICE QUERY message. + +![Sequence diagram of the RIC Service Query procedure. The diagram shows the interaction between a Near-RT RIC and an E2 Node. 1. Near-RT RIC decides to query E2 Node (decision point). 2. Near-RT RIC sends RIC SERVICE QUERY to E2 Node. 3. E2 Node compares list of RIC services in query message with current configuration on E2 Node. 4. The process concludes with the RIC Service Update procedure, which then feeds back into the Near-RT RIC.](dadd1f94977abeaf71bcb106d150a167_img.jpg) + +``` + +sequenceDiagram + participant NRT as Near-RT RIC + participant E2 as E2 Node + Note over NRT: Near-RT RIC decides to query E2 Node + NRT->>E2: RIC SERVICE QUERY + Note over E2: Compare list of RIC services in query message with current configuration on E2 Node + E2-->>NRT: + Note over NRT: RIC Service Update procedure + +``` + +Sequence diagram of the RIC Service Query procedure. The diagram shows the interaction between a Near-RT RIC and an E2 Node. 1. Near-RT RIC decides to query E2 Node (decision point). 2. Near-RT RIC sends RIC SERVICE QUERY to E2 Node. 3. E2 Node compares list of RIC services in query message with current configuration on E2 Node. 4. The process concludes with the RIC Service Update procedure, which then feeds back into the Near-RT RIC. + +**Figure 5.5.4A-1: RIC Service Query procedure** + +### 5.5.5 E2 Node Configuration Update procedure + +The E2 Node Configuration Update procedure is used by the E2 Node to inform the Near-RT RIC of any change to the configuration of the E2 Node and/or E2 Node initiated changes to TNL Associations associated with the E2 interface. The configuration information is specific to the E2 Node type (see clause 4.2) and based on the re-use of 3GPP RAN3 defined configuration update messages. + +See clause 6.2 for further details on E2 Node Configuration Update procedure usage for E2 Node initiated changes to TNL Associations associated with the E2 interface. + +![Sequence diagram for E2 Node Configuration Update procedure](d8474ec6c5d09beb8478076fce3b0853_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Note over E2 Node: Change to E2 node system configuration + E2 Node->>Near-RT RIC: E2 NODE CONFIGURATION UPDATE +(E2 node configuration information) + Note over Near-RT RIC: Near-RT RIC extracts list of changes +to E2 Node configuration information +and updates stored information + Near-RT RIC->>E2 Node: E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE +(E2 node configuration ack) + +``` + +The diagram illustrates the E2 Node Configuration Update procedure. It involves two main entities: Near-RT RIC and E2 Node. The process begins with the E2 Node initiating a 'Change to E2 node system configuration'. This is followed by the E2 Node sending an 'E2 NODE CONFIGURATION UPDATE (E2 node configuration information)' message to the Near-RT RIC. Upon receiving this message, the Near-RT RIC performs an internal action: 'Near-RT RIC extracts list of changes to E2 Node configuration information and updates stored information'. Finally, the Near-RT RIC sends an 'E2 NODE CONFIGURATION UPDATE ACKNOWLEDGE (E2 node configuration ack)' message back to the E2 Node. + +Sequence diagram for E2 Node Configuration Update procedure + +**Figure 5.5.5-1: E2 Node Configuration Update procedure** + +### 5.5.6 E2 Removal procedure + +The E2 Removal procedure is used by either the E2 Node or Near-RT RIC to release the E2 signalling connection. + +If the procedure is E2 node initiated, after the E2 REMOVAL RESPONSE is received, the E2 node initiates termination of all TNL associations associated with this E2 interface. The Near-RT RIC and E2 nodes releases all resources associated with this E2 interface. If the E2 Removal procedure fails, the E2 node may retry the E2 Removal procedure. + +If the procedure is Near-RT RIC initiated, after the E2 REMOVAL RESPONSE is received, the Near-RT RIC initiates termination of all TNL associations associated with this E2 interface. The Near-RT RIC and E2 nodes releases all resources associated with this E2 interface. If the E2 Removal procedure fails, the Near-RT RIC may retry the E2 Removal procedure. + +![Sequence diagram for E2 Removal procedure](fa2335b22d10571686c714dacaa779e7_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Note over E2 Node: E2 Node decides to release +E2 interface + E2 Node->>Near-RT RIC: E2 REMOVAL REQUEST + Near-RT RIC->>E2 Node: E2 REMOVAL RESPONSE + Note over E2 Node: SCTP connection termination + Note over Near-RT RIC: Remove all resources associated +with the E2 interface + Note over E2 Node: Remove all resources associated +with the E2 interface + +``` + +The diagram illustrates the E2 Removal procedure. It involves two main entities: Near-RT RIC and E2 Node. The process begins with the E2 Node initiating an 'E2 Node decides to release E2 interface'. This is followed by the E2 Node sending an 'E2 REMOVAL REQUEST' message to the Near-RT RIC. Upon receiving this message, the Near-RT RIC sends an 'E2 REMOVAL RESPONSE' message back to the E2 Node. Simultaneously, both entities perform an internal action: 'Remove all resources associated with the E2 interface'. Finally, the E2 Node initiates 'SCTP connection termination'. + +Sequence diagram for E2 Removal procedure + +**Figure 5.5.6-1: E2 Removal procedure (E2 Node initiated)** + +![Sequence diagram for E2 Removal procedure (Near-RT RIC initiated)](a1ecef82c07a5943ace495a2d0c3cd50_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Note over Near-RT RIC: Near-RT RIC decides to +release E2 interface + Near-RT RIC->>E2 Node: E2 REMOVAL REQUEST + E2 Node-->>Near-RT RIC: E2 REMOVAL RESPONSE + Near-RT RIC->>E2 Node: SCTP connection termination + Note over Near-RT RIC: Remove all resources associated +with the E2 interface + Note over E2 Node: Remove all resources associated +with the E2 interface + +``` + +The diagram illustrates the E2 Removal procedure initiated by the Near-RT RIC. It shows the interaction between the Near-RT RIC and the E2 Node. The process begins with the Near-RT RIC deciding to release the E2 interface. This is followed by the Near-RT RIC sending an E2 REMOVAL REQUEST to the E2 Node. The E2 Node responds with an E2 REMOVAL RESPONSE. A dashed line indicates the SCTP connection termination. Finally, both the Near-RT RIC and the E2 Node remove all resources associated with the E2 interface. + +Sequence diagram for E2 Removal procedure (Near-RT RIC initiated) + +**Figure 5.5.6-2: E2 Removal procedure (Near-RT RIC initiated)** + +### 5.5.7 E2 Resource Status + +This procedure is used by a Near-RT RIC to request the reporting of load measurements to E2 node. During this procedure, the E2 Node provides the E2 node level resource status and traffic load information over the E2 interface. + +If the E2 Resource Status initiation fails, the Near-RT RIC may retry the E2 Resource Status initiation procedure. + +![Sequence diagram for E2 Resource Status procedure](528a5eff28fbb4b153e86f28d45e21e0_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Note over Near-RT RIC: Near-RT RIC decides to start/stop +Load measurement to E2 Node + Near-RT RIC->>E2 Node: E2 RESOURCE STATUS REQUEST + Note over E2 Node: E2 Node Start/stop the requested measurement +according to the parameters given in the request + E2 Node-->>Near-RT RIC: E2 RESOURCE STATUS RESPONSE + +``` + +The diagram illustrates the E2 Resource Status procedure. It shows the interaction between the Near-RT RIC and the E2 Node. The process begins with the Near-RT RIC deciding to start/stop Load measurement to the E2 Node. This is followed by the Near-RT RIC sending an E2 RESOURCE STATUS REQUEST to the E2 Node. The E2 Node then starts/stops the requested measurement according to the parameters given in the request. Finally, the E2 Node sends an E2 RESOURCE STATUS RESPONSE back to the Near-RT RIC. + +Sequence diagram for E2 Resource Status procedure + +**Figure 5.5.7-1: E2 Resource Status procedure** + +### 5.5.8 E2 Resource Status Update + +The E2 Resource Status Update is used by the E2 Node to inform the Near-RT RIC of the results of the resource measurements that were successfully initiated during the preceding E2 Resource Status procedure (see clause 5.5.7). After the E2 Resource Status Update is received containing information describing the available resources in the E2 Node, the Near-RT RIC may suspend the initiation of new RIC procedures or may initiate RIC Subscription Delete procedures to reduce E2 Node load. + +![Sequence diagram showing the E2 Resource Status Update procedure. An E2 Node reports results to a Near-RT RIC, which then sends an E2 RESOURCE STATUS UPDATE message to another Near-RT RIC.](e89ab438de3870b6c4bd129c13f8a1ae_img.jpg) + +``` + +sequenceDiagram + participant E2Node1 as E2 Node + participant NearRT RIC1 as Near-RT RIC + participant NearRT RIC2 as Near-RT RIC + participant E2Node2 as E2 Node + + E2Node1-->>NearRT RIC1: E2 Node reports the results of the admitted measurements + NearRT RIC1-->>NearRT RIC2: E2 RESOURCE STATUS UPDATE + +``` + +Sequence diagram showing the E2 Resource Status Update procedure. An E2 Node reports results to a Near-RT RIC, which then sends an E2 RESOURCE STATUS UPDATE message to another Near-RT RIC. + +Figure 5.5.8-1: E2 Resource Status Update procedure + +# 6 E2 interface signalling + +## 6.1 E2 control plane protocol (E2AP) + +The control plane protocol stack of the E2AP interface is shown on Figure 6.1-1. + +The transport network layer is built on IP transport. For the reliable transport of signalling messages, IETF RFC 4960 [12] is added on top of IP. + +When configurations with multiple SCTP associations are supported, the Near-RT RIC may request to dynamically add/remove SCTP associations between the E2 Node/Near-RT RIC pair. Within the set of SCTP associations established between one Near-RT RIC and E2 node pair, the Near-RT RIC may request the E2 Node to restrict the usage of SCTP association for certain types of E2 signalling. If no restriction information is provided for an SCTP association, any type of E2 signalling is allowed via the SCTP association. + +The application layer signalling protocol is referred to as E2AP (E2 Application Protocol). The Payload Protocol Identifier assigned by IANA to be used by SCTP for the application layer protocol E2AP is 70. This value is to be used for all deployment configurations described in the present document. Payload Protocol Identifiers 71 and 72, also assigned by IANA for E2, are reserved for future use. + +No SCTP Destination Port number value was assigned by IANA for the E2AP protocol and so networks shall rely on E2 node and Near-RT RIC configuration to select a suitable port number. + +![Figure 6.1-1: E2AP protocol stack diagram. The diagram shows a protocol stack divided into two main sections: Radio Network Layer and Transport Network Layer. The Radio Network Layer contains the E2AP protocol. The Transport Network Layer contains Sctp, IP, Data Link Layer, and Physical Layer. A horizontal line separates the two layers, with a small circle at the center of the line.](d230f4b1b10b144ce53e6aaa89d77ca4_img.jpg) + +``` + +graph TD + subgraph Radio_Network_Layer [Radio Network Layer] + E2AP[E2AP] + end + subgraph Transport_Network_Layer [Transport Network Layer] + Sctp[Sctp] + IP[IP] + Data_Link_Layer[Data Link Layer] + Physical_Layer[Physical Layer] + end + E2AP --- Sctp + Sctp --- IP + IP --- Data_Link_Layer + Data_Link_Layer --- Physical_Layer + +``` + +Figure 6.1-1: E2AP protocol stack diagram. The diagram shows a protocol stack divided into two main sections: Radio Network Layer and Transport Network Layer. The Radio Network Layer contains the E2AP protocol. The Transport Network Layer contains Sctp, IP, Data Link Layer, and Physical Layer. A horizontal line separates the two layers, with a small circle at the center of the line. + +NOTE 1: E2AP messages are transported over the E2 interfaces. + +**Figure 6.1-1: E2AP protocol stack** + +## 6.2 Multiple TNLAs over E2 + +The Near-RT RIC and E2 Node supports multiple TNL associations over E2 interface. + +An initial TNL association is established during E2 Setup procedure with E2 Node initiating Sctp connection. At this point the single TNL association is configured to be used for both RIC Services (clause 5.3) and E2 Support functions (clause 5.5). + +TNL associations may then be added, modified or removed during subsequent E2 Connection Update and E2 Node Configuration Update procedures with E2 Node initiating Sctp connections where required. + +When the Near-RT RIC requests to dynamically add additional Sctp associations between the Near-RT RIC/E2 Node pair, the Near-RT RIC sends additional Sctp endpoints using the E2 Connection Update procedure. The E2 Node shall establish the Sctp associations. The Sctp Destination Port number value may be the same port number used for the initial E2 Setup procedure, or any dynamic port value (IETF RFC 6335 [23]). + +Within the set of Sctp associations established between one Near-RT RIC and E2 node pair, a single Sctp association shall be employed for E2AP elementary procedures utilized for E2 Support Function signalling (i.e. defined in O-RAN WG3.TS.E2AP [2] clause 8.3) with the possibility of fail-over to a new association to enable robustness. + +When the configuration with multiple Sctp endpoints per E2 node is supported and E2 node wants to add an additional Sctp association, the E2 Node Configuration Update procedure shall be the first E2AP procedure triggered on an additional TNLA of an already setup E2 interface after the TNL association has become operational. The E2 Node uses a Sctp endpoint of the Near-RT RIC already in use for existing TNL associations between the Near-RT RIC/E2 Node pair when establishing the additional Sctp association, and the Near-RT RIC shall associate the TNLA to the E2 interface using the included Global E2 Node ID. The E2 Node uses the E2 Node Configuration Update procedure when it wants to remove additional Sctp association. + +The RIC Subscription TNLA binding is a binding between a specific TNL association and RIC Service signalling (i.e. defined in O-RAN WG3.TS.E2AP [2] clause 8.2) of a specific RIC Subscription. After the RIC Subscription TNLA binding is created, the Near-RT RIC can update the RIC Subscription TNLA binding by sending the E2AP message for the RIC Subscription to the E2 Node via a different TNLA. The E2 Node shall update the RIC Subscription TNLA binding with the new TNLA. The E2 Configuration Update procedure also allows the E2 Node to inform the Near-RT RIC that the indicated TNLA(s) will be removed by the E2 Node. + +Between one Near-RT RIC and E2 Node pair: + +- A single pair of stream identifiers shall be reserved over an SCTP association for the sole use of E2AP elementary procedures utilized for E2 Support Function signalling (i.e. defined in O-RAN WG3.TS.E2AP [2] clause 8.3). +- At least one pair of stream identifiers over one or several SCTP associations shall be reserved for the sole use of E2AP elementary procedures utilized for RIC Service signalling (i.e. defined in O-RAN WG3.TS.E2AP [2] clause 8.2). However, a few pairs (i.e. more than one) should be reserved. +- For any RIC service signalling (i.e. defined in O-RAN WG3.TS.E2AP [2] clause 8.2) of a single RIC Subscription, the E2 Node shall use one SCTP association and one SCTP stream, and the SCTP association/stream should not be changed until after the current SCTP association is failed, or the RIC Subscription TNLA binding update is performed. + +Transport network redundancy may be achieved by SCTP multi-homing between two end-points, of which one or both is assigned with multiple IP addresses. SCTP end-points shall support a multi-homed remote SCTP end-point. For SCTP endpoint redundancy an INIT may be sent from a Near-RT RIC or E2 Node, at any time for an already established SCTP association, which shall be handled as defined in IETF RFC 4960 [12] in sub clause 5.2. + +The SCTP congestion control may, using an implementation specific mechanism, initiate higher layer protocols to reduce the signalling traffic at the source and prioritize certain messages. + +![Sequence diagram showing TNL management examples between Near-RT RIC and E2 Node.](29aa34df00d65c93f76a99751c9f2d57_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Note right of E2 Node: E2 Node obtains Near-RT RIC IP address and Port number + Near-RT RIC->>E2 Node: SCTP INIT + E2 Node->>Near-RT RIC: SCTP connection (TNLA1) + Near-RT RIC->>E2 Node: E2 SETUP REQUEST + E2 Node->>Near-RT RIC: E2 SETUP RESPONSE + Note over Near-RT RIC, E2 Node: E2 interface using TNLA1 + Near-RT RIC->>E2 Node: E2 CONNECTION UPDATE (TNLA2 addition) + E2 Node->>Near-RT RIC: SCTP INIT + E2 Node->>Near-RT RIC: SCTP connection (TNLA2) + E2 Node->>Near-RT RIC: E2 CONNECTION UPDATE ACKNOWLEDGE (Status TNLA1, TNLA2) + Note over Near-RT RIC, E2 Node: E2 interface using TNLA1 and TNLA2 + +``` + +The diagram illustrates two scenarios for TNL management between a Near-RT RIC and an E2 Node. In the first scenario, the E2 Node initiates the connection by sending an SCTP INIT message to the Near-RT RIC, which responds with SCTP connection (TNLA1). The Near-RT RIC then sends an E2 SETUP REQUEST, and the E2 Node responds with an E2 SETUP RESPONSE. This results in an E2 interface using TNLA1. In the second scenario, the Near-RT RIC initiates the connection by sending an E2 CONNECTION UPDATE (TNLA2 addition) to the E2 Node. The E2 Node responds with an SCTP INIT message, followed by SCTP connection (TNLA2). The E2 Node then sends an E2 CONNECTION UPDATE ACKNOWLEDGE (Status TNLA1, TNLA2) to the Near-RT RIC, resulting in an E2 interface using both TNLA1 and TNLA2. + +Sequence diagram showing TNL management examples between Near-RT RIC and E2 Node. + +**Figure 6.2-1: TNL management examples (E2 Setup and Near-RT RIC initiated TNL Addition)** + +![Sequence diagram showing TNL management examples between Near-RT RIC and E2 Node. The diagram illustrates two scenarios: TNL modification and TNL removal. In the first scenario, the Near-RT RIC sends an 'E2 CONNECTION UPDATE (TNLA1 and TNLA2 modification)' to the E2 Node, which then sends an 'E2 CONNECTION UPDATE ACKNOWLEDGE (Status TNLA1, TNLA2)' back. A callout box indicates 'Modify usage assignments for TNLA1 and TNLA2'. In the second scenario, the Near-RT RIC sends an 'E2 CONNECTION UPDATE (TNLA1 removal)' to the E2 Node, which then sends an 'SCTP connection removal (TNLA1)' back. A callout box indicates 'Modify usage assignments for TNLA1 and TNLA2'. Finally, the Near-RT RIC sends an 'E2 CONNECTION UPDATE ACKNOWLEDGE (Status TNLA2)' back to the E2 Node.](93c8b2ed3ba0ccb062b2f04ba5012b26_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + + Note over Near-RT RIC, E2 Node: E2 interface using TNLA1 and TNLA2 + Near-RT RIC->>E2 Node: E2 CONNECTION UPDATE (TNLA1 and TNLA2 modification) + Note right of E2 Node: Modify usage assignments for TNLA1 and TNLA2 + E2 Node-->>Near-RT RIC: E2 CONNECTION UPDATE ACKNOWLEDGE (Status TNLA1, TNLA2) + Note over Near-RT RIC, E2 Node: E2 interface using TNLA1 and TNLA2 with modified usage + + Note over Near-RT RIC, E2 Node: E2 CONNECTION UPDATE (TNLA1 removal) + Near-RT RIC->>E2 Node: E2 CONNECTION UPDATE (TNLA1 removal) + E2 Node-->>Near-RT RIC: SCTP connection removal (TNLA1) + Note right of E2 Node: Modify usage assignments for TNLA1 and TNLA2 + Near-RT RIC-->>E2 Node: E2 CONNECTION UPDATE ACKNOWLEDGE (Status TNLA2) + Note over Near-RT RIC, E2 Node: E2 interface using TNLA2 + +``` + +Sequence diagram showing TNL management examples between Near-RT RIC and E2 Node. The diagram illustrates two scenarios: TNL modification and TNL removal. In the first scenario, the Near-RT RIC sends an 'E2 CONNECTION UPDATE (TNLA1 and TNLA2 modification)' to the E2 Node, which then sends an 'E2 CONNECTION UPDATE ACKNOWLEDGE (Status TNLA1, TNLA2)' back. A callout box indicates 'Modify usage assignments for TNLA1 and TNLA2'. In the second scenario, the Near-RT RIC sends an 'E2 CONNECTION UPDATE (TNLA1 removal)' to the E2 Node, which then sends an 'SCTP connection removal (TNLA1)' back. A callout box indicates 'Modify usage assignments for TNLA1 and TNLA2'. Finally, the Near-RT RIC sends an 'E2 CONNECTION UPDATE ACKNOWLEDGE (Status TNLA2)' back to the E2 Node. + +Figure 6.2-2: TNL management examples (Near-RT RIC initiated TNL Modification and TNL Removal) + +![Sequence diagram showing TNL management examples (E2 Node initiated TNL Addition and TNL Removal) between Near-RT RIC and E2 Node.](92d321eb2987f8a81950f3faedf1aa76_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant E2 Node + Note over Near-RT RIC, E2 Node: E2 interface using TNLA1 + Note right of E2 Node: E2 Node decides to add TNLA2 + E2 Node-->>Near-RT RIC: Sctp Init + Note over Near-RT RIC, E2 Node: Sctp connection(TNLA2) + E2 Node-->>Near-RT RIC: E2 Node Configuration Update (Global E2 Node ID) + Note left of Near-RT RIC: Near-RT RIC binds Sctp connection to E2 Node + Near-RT RIC-->>E2 Node: E2 Node Configuration Update Acknowledge + Note over Near-RT RIC, E2 Node: E2 interface using TNLA1 and TNLA2 + E2 Node-->>Near-RT RIC: E2 Node Configuration Update (Remove TNLA1) + Note over Near-RT RIC, E2 Node: E2 Node Configuration Update Acknowledge + E2 Node-->>Near-RT RIC: Sctp connection removal(TNLA1) + Note over Near-RT RIC, E2 Node: E2 interface using TNLA2 + +``` + +The diagram illustrates the TNL management process between a Near-RT RIC and an E2 Node. It shows three states of the E2 interface: using TNLA1, using both TNLA1 and TNLA2, and using only TNLA2. The process begins with the E2 Node deciding to add TNLA2. This triggers an Sctp Init message from the E2 Node to the Near-RT RIC, followed by an Sctp connection(TNLA2) message. The E2 Node then sends an E2 Node Configuration Update (Global E2 Node ID) to the Near-RT RIC. The Near-RT RIC binds the Sctp connection to the E2 Node and sends an E2 Node Configuration Update Acknowledge message back to the E2 Node. The E2 interface then transitions to using both TNLA1 and TNLA2. Subsequently, the E2 Node sends an E2 Node Configuration Update (Remove TNLA1) to the Near-RT RIC, followed by an E2 Node Configuration Update Acknowledge message. Finally, the E2 Node sends an Sctp connection removal(TNLA1) message to the Near-RT RIC, and the E2 interface transitions to using only TNLA2. + +Sequence diagram showing TNL management examples (E2 Node initiated TNL Addition and TNL Removal) between Near-RT RIC and E2 Node. + +Figure 6.2-3: TNL management examples (E2 Node initiated TNL Addition and TNL Removal) + +# 7 Security for the E2 interface + +## 7.1 General + +The security requirements given in this clause only apply to the E2 interface. + +## 7.2 Requirements for the E2 interfaces + +The requirements given below apply to E2 interface defined in the present document: + +- E2 interface shall support confidentiality, integrity, replay protection and data origin authentication. + +## 7.3 Security mechanism for the E2 interface + +In order to protect the traffic on the E2 interface, IPsec ESP implementation shall be supported according to IETF RFC 4303 [20] as profiled by 3GPP TS 33.210 [21]. For IPsec implementation, tunnel mode is mandatory to support while transport + +mode is optional. The multiple IKE Security Associations (SAs), multiple IPsec SAs and multiple IPsec SAs per IPsec tunnel (e.g. for rekeying) shall be supported. + +IKEv2 certificate-based authentication implementation shall be supported according to 3GPP TS 33.310 [22]. The certificates shall be supported according to the profile described by 3GPP TS 33.310 [22]. IKEv2 shall be supported conforming to the IKEv2 profile described in 3GPP TS 33.310 [22]. + +# --- 8 Other E2 interface specifications + +## 8.1 O-RAN E2 interface: E2 Application Protocol (E2AP) (ORAN-WG3.E2AP) + +The technical specification ORAN WG3.E2AP [2] specifies the signalling protocol between the Near-RT RIC and the E2 Node over the E2 interface. + +## 8.2 O-RAN E2 interface: E2 Service Model (E2SM) specifications + +The technical specification ORAN WG3.E2SM [17] provides the list of the supported RAN Function-specific E2 Service Models supported over the E2 interface and presents a recommended layout for additional E2SM specifications. + +# Annex A (normative): Deployment considerations + +## A.1 Deployment use cases + +The Near-RT RIC may be connected to range of different E2 Node configurations as described in the list implementation options in Annex A.4 of O-RAN WG1.TS.OAD [18]. Examples include: + +- Standalone O-CU-CP connected to one or more standalone O-CU-UP and one or more standalone O-DU. Each logical node is considered as an E2 Node that presents an E2 interface to the Near-RT RIC. +- Combined O-CU-CP and O-CU-UP connected to one or more standalone O-DU. The combined O-CU-CP/O-CU-UP may present either a common E2 interface or individual E2 interfaces corresponding to the individual O-RAN components +- Combined O-CU-CP, O-CU-UP and O-DU. The combined node may present either a common E2 interface or individual E2 interfaces corresponding to the individual O-RAN components + +In all cases the different RAN components may initiate either independent E2 connections to the Near-RT RIC for each logical O-RAN component or may present a shared E2 interface and hence present the combined RAN components as a common E2 Node supporting services appropriate to more than one logical O-RAN component. + +In all cases each E2 Node shall present a single E2 interface to the Near-RT RIC and shall announce which E2 Services supports for each logical O-RAN component. + +Example deployment use case are presented in Figures A.1-1 and A.1-2. + +![Figure A.1-1: Example deployment use case with single E2 Node supporting both O-CU-CP and O-CU-UP roles. The diagram shows a hierarchical structure. At the top is the 'Near-RT RIC'. Below it, two orange boxes represent 'E2 Node' configurations. The first 'E2 Node' contains 'O-CU-CP' and 'O-CU-UP' connected by an 'E1' interface. The second 'E2 Node' contains 'O-DU'. Both 'E2 Node' boxes are connected to the 'Near-RT RIC' via 'E2' interfaces. The 'O-CU-CP' is connected to 'O-DU' via an 'F1-c' interface. The 'O-CU-UP' is connected to 'O-DU' via an 'F1-u' interface. Finally, 'O-DU' is connected to 'O-RU' via an 'Open Fronthaul' interface.](33771de5f196201ae695abbd356a8666_img.jpg) + +``` + +graph TD + NR[Near-RT RIC] + subgraph E2_Nodes [E2 Nodes] + subgraph E2_Node1 [E2 Node] + OCU_CP[O-CU-CP] + OCU_UP[O-CU-UP] + OCU_CP --- E1 --- OCU_UP + end + subgraph E2_Node2 [E2 Node] + ODU[O-DU] + end + end + NR --- E2_1[E2] + NR --- E2_2[E2] + E2_Node1 --- F1c[F1-c] --- ODU + E2_Node1 --- F1u[F1-u] --- ODU + ODU --- OF[Open Fronthaul] --- ORU[O-RU] + +``` + +Figure A.1-1: Example deployment use case with single E2 Node supporting both O-CU-CP and O-CU-UP roles. The diagram shows a hierarchical structure. At the top is the 'Near-RT RIC'. Below it, two orange boxes represent 'E2 Node' configurations. The first 'E2 Node' contains 'O-CU-CP' and 'O-CU-UP' connected by an 'E1' interface. The second 'E2 Node' contains 'O-DU'. Both 'E2 Node' boxes are connected to the 'Near-RT RIC' via 'E2' interfaces. The 'O-CU-CP' is connected to 'O-DU' via an 'F1-c' interface. The 'O-CU-UP' is connected to 'O-DU' via an 'F1-u' interface. Finally, 'O-DU' is connected to 'O-RU' via an 'Open Fronthaul' interface. + +**Figure A.1-1: Example deployment use case with single E2 Node supporting both O-CU-CP and O-CU-UP roles** + +![Figure A.1-2: Example deployment use case with single E2 Node supporting O-CU-CP, O-CU-UP and O-DU roles](92f2ea0f78ab36baf6cb383e860ec5be_img.jpg) + +The diagram illustrates a network architecture where a single E2 Node supports multiple roles. At the top is the **Near-RT RIC**. An orange line labeled **E2** connects the Near-RT RIC to the **E2 Node**. The **E2 Node** is represented by an orange-bordered box containing three components: **O-CU-CP**, **O-CU-UP**, and **O-DU**. Inside the E2 Node box, **O-CU-CP** is connected to **O-CU-UP** via an **E1** interface. **O-CU-CP** is also connected to **O-DU** via an **F1-c** interface. **O-CU-UP** is connected to **O-DU** via an **F1-u** interface. Below the E2 Node box, the **O-DU** component is connected to the **O-RU** (Radio Unit) via an **Open Fronthaul** interface. + +Figure A.1-2: Example deployment use case with single E2 Node supporting O-CU-CP, O-CU-UP and O-DU roles + +Figure A.1-2: Example deployment use case with single E2 Node supporting O-CU-CP, O-CU-UP and O-DU roles + +# Annex B (informative): Change history + +| Date | Revision | Description | +|-------------------|---------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2020.01.22 | 01.00.00 | Specification renamed v01.00.00 for approval by WG3 | +| 2020.01.29 | 01.00.00 | Editorial corrections collected during WG3 approval process | +| 2020.02.06 | 01.00.00 | Updated Text based on outcome of SCTP Port ID application process | +| <b>2020.02.06</b> | <b>V01.00</b> | <b>Initial version</b> | +| | | | +| 2020.03.11 | 01.00.01 | Implementing CRs (for maintenance) agreed in Virtual F2F February 2020. | +| 2020.03.11 | 01.00.02 | Small editorial on Section 4. | +| 2020.07.08 | 01.00.03 | Alignment with published v01.00.00 version (copyright statement)<br>Inclusion of approved CRs from meeting #60 and co-chair editorial changes | +| <b>2020.07.15</b> | <b>v01.01</b> | <b>Editorial and functional corrections</b> | +| | | | +| 2021.02.23 | V02.00.01 | Adding Security related CRs. | +| 2021.03.09 | V02.00.02 | TNL related CRs | +| 2021.06.03 | V02.00.03 | Merging CRs related to Control Service enhancements and RIC Subscription delete (WG3#100) | +| <b>2021.08.10</b> | <b>V02.00</b> | <b>New features: RIC Subscription Delete, TNLA Removal. Improvement to security text</b> | +| | | | +| 2021.11.02 | V02.01.01 | Added CRs <INT-2021.10.13-WG3-CR-0012-E2GAP-clarify_multipleTNLA_handling_vS > approved WG3#116<br>< SAM-2021.10.13-WG3-CR-0001-E2GAP_E2Removal-v04 > approved WG#117 | +| 2021.11.22 | V02.01.02 | Corrections based on WG3 approval review responses. | +| <b>2022.02.07</b> | <b>V02.01</b> | <b>New features: E2 Removal. Clarification on handling of multiple TNLAs</b> | +| | | | +| 2022.03.23 | V02.02.01 | Added CR < NOK.AO-2022.02.11-WG3-CR-0008-E2GAP-Clarification for REPORT and INSERT in 5.3.3-v01 > approved WG3#137 | +| 2022.04.04 | V02.02.02 | Editorial corrections based on feedback received during WG3 approval poll | +| <b>2022.06.29</b> | <b>V02.02</b> | <b>Clarification on REPORT and INSERT service handling. Editorial and functional corrections</b> | +| | | | +| 2022.11.10 | V02.02.01 | Editorial changes:<br>- Update to latest O-RAN template<br>- Addition of “skin rose” to maintain existing WG3 look for all plantUML figures<br>- Changes to table 5.3.2.6-1 introducing RIC service names<br>- Alignment of message names in figures to common naming convention (Xxxx procedure for entire procedures, XXXX for individual messages)<br><br>Addition of approved CRs:<br>- NOK.AO-2022.02.08-WG3-CR-0007-E2GAP-Combining RIC Services-v04<br>- NOK.AO-2021.11.24-WG3-CR-0005-E2GAP-RIC-Subscription-Modification-v07<br>- MAV.AO-2022.10.04-WG3-CR-0013 E2GAP 03.00 RIC Query Service-v10 | +| 2022.11.16 | V02.02.02 | Changes reflecting remarks received during WG3 approval process<br>- Alignment to latest O-RAN template<br>- Align text in 5.3.2.5A with 5.3.2.4 “The Near-RT RIC shall set the timer...”<br>- Add reference to “previous” and “subsequent” RIC actions to REPORT, INSERT and POLICY services in section 5.3.2<br>- Added R003 to file name<br>- Updated copyright year<br>- Harmonised use of term “RIC Service”, deleting incorrect usage of term “Near-RT RIC Service”, changing “RIC REPORT Service” to read “RIC Service REPORT”, etc. in sections 5.3.1, 5.4, 5.5<br>- Harmonised language used to describe E2SM IEs in section 5.4 | +| <b>2022.11.21</b> | <b>V03.00</b> | <b>New features: RIC Subscription Modification, RIC Query. Clarification on Combining RIC Services, Timer handling, RIC Action execution order, use of term RIC Service</b> | +| | | | + +| Date | Revision | Description | +|-------------------|---------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.02.01 | V03.00.01 | Addition of CRs:<br>- <NOK-2023.01.30-WG3-CR-0009-E2GAP-PAS step1-v01> approved WG3#172 | +| 2023.03.16 | V03.00.02 | Addition of CRs:<br>- <NOK-2023.03.13-WG3-CR-0010-E2GAP-PAS step2-v02> approved by correspondence after WG3#176 | +| 2023.03.24 | V03.00.03 | Inclusion of corrections agreed during WG3 approval process as per < O-RAN.WG3.E2GAP-R003-v03.00.02- ApprovalChanges-v3 > | +| <b>2023.03.24</b> | <b>V03.01</b> | <b>Alignment of O-RAN Drafting Rules (ODR) in preparation for ETSI PAS submission</b> | +| 2023.05.15 | V03.01.01 | CR <NOK-2023.04.28-WG3-CR-0011-E2GAP-Correction to clause 2.1-v01> approved WG3#183<br>CR <NOK.AO-2023.05.17-WG3-CR-0012-E2GAP-fig4.2-1-v02> approved WG3#185 | +| 2023.06.27 | V03.01.02 | CR < NOK.AO-2023.06.19-WG3-CR-0014-E2GAP-figA.1-v02> approved F2F Osaka | +| 2023.07.19 | V03.01.03 | CR <NOK-2023.07.17-WG3-CR-0015-E2GAP-Ref24 removal-v03> approved WG3#191 | +| 2023.07.26 | V03.01.04 | Editorial changes based on comments received during WG3 poll. | +| 2023.07.27 | V03.01.05 | Editorial changes to align to O-RAN TS template v01.01 | +| 2023.07.28 | V04.00 | Version ready for July 23 train (withdrawn) | +| 2023.09.27 | V04.01 | CR <NOK-2023.09.25-WG3-CR-0014-E2GAP-Clause5.4heading-v01> approved WG3#200 as a pre-publication correction to v04.00 | +| <b>2023.09.27</b> | <b>V04.01</b> | <b>Editorial and functional corrections</b> | +| 2023.10.04 | V04.01.01 | CR < NOK.AO-2023.05.22-WG3-CR-0013-E2GAP-SubscriptionAudit-v05 > approved WG3#201 | +| 2023.11.15 | V04.01.02 | Editorial corrections implementing WG3 voting period feedback | +| 2023.11.21 | V04.01.03 | Restored full revision history into Annex: Change History and deletion of Annex: History | +| <b>2023.11.21</b> | <b>V05.00</b> | <b>New feature: RIC Subscription Audit. Editorial and functional corrections</b> | +| 2024.02.29 | V05.00.01 | CR <NOK-2024.02.13-WG3-CR-0016-E2GAP-Change history-v01> approved F2F Athens | +| 2024.04.22 | V05.00.02 | CR < NOK-2024.03.07-WG3-CR-0017-E2GAP-Editorial corrections for PAS-step3-v5> approved WG3#225<br>Also includes editorial changes to align with ETSI “Edit Help” changes during PAS processing of v04.01 | +| 2024.06.21 | V05.00.03 | CR < NOK-2024.05.31-E2GAP-CR-0019-Removing validated step-v01> approved WG3#227<br>CR < NOK-2024.05.31-E2GAP-CR-0020-E2 Node configuration information source-v01> approved WG3 Incheon F2F<br>CR < NOK.AO-2024.05.31-E2GAP-CR-0021-E2 interface compliance to 3GPP-v01> approved WG3#227<br>CR < NOK-2024.05.31-E2GAP-CR-0018-Alignment of terminology for non RIC Service related procedures-v03> approved WG3#229 | +| 2024.07.26 | V05.00.04 | Editorial corrections implementing review comments collected during July24 train approval | +| <b>2024.07.26</b> | <b>V06.00</b> | <b>Alignment to ETSI Drafting Rules and implementation of all agreed ETSI PAS comments</b> | +| | | | + +| Date | Revision | Description | +|------------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.08.06 | V06.00.01 | CR <ZTE.AO-2024.07.23-WG3-CR-0001-E2GAP-Addressing concerns on clause 5.1.1-v01> approved WG3#233<br>CR < NOK.AO-2024.07.23-WG3-CR-0022-E2GAP-E2 Overload-v03.docx > approved WG#234 | +| 2024.10.16 | V06.00.02 | CR <NOK-2024.09.27-E2GAP-CR-0025-EditHelp alignment-v2> approved WG3#241 | +| 2024.11.21 | V06.00.03 | Editorial changes to align with O-RAN WORKPROC v04.00<br>CR <RSYS.AO-2024.07.23-WG3-CR-0002-E2GAP- Support of Resource Status Report-v04> approved WG3#236<br>CR <NOK-2024.10.22-WG3-CR-0027-E2GAP-Handling LS from MSG-v04 > approved F2F Montreal<br>CR <NOK-2024.09.30-E2GAP-CR-0028-RIC Subscription State Control-v1 > approved WG3#243<br>CR < NOK.AO-2024.09.30-WG3-CR-0026-E2GAP-modification to E2 Overload-v4 > approved WG3#244<br>CR <NOK-2024.09.16-E2GAP-CR-0029-E2 Service Model Error handling-v02> approved WG3#245<br>CR <NOK-2024.09.16-WG3-CR-0024-E2GAP-RIC Assistance service-v08> approved WG3#245<br>Editorial correction to v06.00.01 implementation of CR <ZTE.AO-2024.07.23-WG3-CR-0001-E2GAP-Addressing concerns on clause 5.1.1-v01> | +| 2024.12.04 | V07.00 | <b>New features: E2 Resource Status, RIC Subscription State Control, RIC Assistance, Service Level error handling. Implementation of changes related to ETSI MSG Liaison</b> | \ No newline at end of file diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/73bfcbd8e7f257ca547e4b9ef710f8b2_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/73bfcbd8e7f257ca547e4b9ef710f8b2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9549a448128a3eea47b9ee0d5a037d1a866b1dae --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/73bfcbd8e7f257ca547e4b9ef710f8b2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6306fddee0a35f0fc4368b6cbf8324fc137a5e19845bb7fe2592b4682245ec98 +size 4577 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/8df6b0ad37bc7018b9dc2145a6fedde0_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/8df6b0ad37bc7018b9dc2145a6fedde0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2a5567c410ce40b7a54beafadc5ddafffad5b495 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/8df6b0ad37bc7018b9dc2145a6fedde0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c1f01c1714f3eb65a6a43380280eefc9a35f08cb4b0e0e80a2a4a20d656591d6 +size 4529 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/b8f26888eae7135e7062b7bccbd4b573_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/b8f26888eae7135e7062b7bccbd4b573_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..310f688c04a7eda714dc939109591cb46fb02d79 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/b8f26888eae7135e7062b7bccbd4b573_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e39b27c54cb1722a58eec9a6abfae227e7783636ffcdbe8d4ca660b55ddf67f3 +size 4580 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/dcdf82869291af8f38fcf5e76210d790_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/dcdf82869291af8f38fcf5e76210d790_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8975c51fc0bad064772ac222f0c559755f25b381 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/dcdf82869291af8f38fcf5e76210d790_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8750104a3ce3ad8ccea1575d897e6baaa487e7f05bc4dd3d31cd9b2a94352347 +size 4556 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/fbdcd8eae68e222b449455ca371f264f_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/fbdcd8eae68e222b449455ca371f264f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b454602915b38678227444a65749a604eed192d9 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/fbdcd8eae68e222b449455ca371f264f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e1fd3561d6072f5aa979de40761d28308847e9fdd44dbc756d1491912d1df99c +size 4557 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/raw.md b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..0186a8ea009c934bb686a8cf8f05cb705c7ef5ba --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00/raw.md @@ -0,0 +1,3783 @@ + + +# --- **O-RAN Work Group 3 (WG-3) Near-Real-time RAN Intelligent Controller and E2 Interface E2 Service Model (E2SM) Cell Configuration and Control** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|--------------------------------------------------------------------|----| +| Foreword..... | 5 | +| Modal verbs terminology ..... | 5 | +| 1 Scope..... | 6 | +| 2 References ..... | 6 | +| 2.1 Normative references ..... | 6 | +| 2.2 Informative references ..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 7 | +| 3.1 Terms ..... | 7 | +| 3.2 Symbols ..... | 7 | +| 3.3 Abbreviations ..... | 7 | +| 4 General ..... | 7 | +| 4.1 Procedure Specification Principles ..... | 7 | +| 4.2 Forwards and Backwards Compatibility..... | 8 | +| 4.3 Specification Notations..... | 8 | +| 4.4 Void ..... | 8 | +| 5 E2SM Services ..... | 8 | +| 6 RAN Function Service Model Description ..... | 9 | +| 6.1 RAN Function Overview ..... | 9 | +| 6.2 RAN Function exposure services ..... | 9 | +| 6.2.1 REPORT service ..... | 9 | +| 6.2.2 INSERT service..... | 10 | +| 6.2.3 CONTROL service..... | 10 | +| 6.2.4 POLICY service ..... | 10 | +| 6.2.5 QUERY service..... | 10 | +| 6.3 REPORT service description ..... | 10 | +| 6.4 INSERT service description ..... | 10 | +| 6.5 CONTROL service description ..... | 10 | +| 6.6 POLICY service description..... | 11 | +| 6.7 QUERY service description..... | 11 | +| 7 RAN Function Description ..... | 11 | +| 7.1 RAN Function Definition ..... | 11 | +| 7.2 RAN Function name ..... | 11 | +| 7.3 Event trigger styles ..... | 12 | +| 7.3.1 Event trigger style list ..... | 12 | +| 7.3.2 Event trigger style 1: E2 Node Configuration Change ..... | 12 | +| 7.3.3 Event trigger style 2: Periodic..... | 12 | +| 7.4 Supported RIC REPORT Services ..... | 13 | +| 7.4.1 REPORT Service style list ..... | 13 | +| 7.4.2 REPORT Service Style 1: Node-Level Configuration..... | 13 | +| 7.4.3 REPORT Service Style 2: Cell-Level Configuration..... | 14 | +| 7.5 Supported RIC INSERT Services ..... | 14 | +| 7.6 Supported RIC CONTROL Services ..... | 14 | +| 7.6.1 CONTROL Service Style Types..... | 14 | +| 7.6.2 CONTROL Service Style 1: Node Configuration and Control..... | 14 | +| 7.6.3 CONTROL Service Style 2: Cell Configuration and Control..... | 15 | +| 7.7 Supported RIC POLICY Services ..... | 15 | +| 7.7A Supported RIC QUERY Services ..... | 16 | +| 7.7A.1 QUERY Service style list..... | 16 | +| 7.7A.2 QUERY Service Style 1: Node-Level Configuration Query ..... | 16 | +| 7.7A.3 QUERY Service Style 2: Cell-Level Configuration Query ..... | 16 | +| 7.8 Supported RIC Service Styles and E2SM IE Formats..... | 17 | + +| | | | +|--------|------------------------------------------------------------------------|----| +| 8 | RAN Configuration Structures..... | 17 | +| 8.1 | Approach..... | 17 | +| 8.1.1 | RIC Event Trigger Definition ..... | 18 | +| 8.1.2 | RIC Action Definition ..... | 19 | +| 8.1.3 | Report Indication..... | 20 | +| 8.1.4 | Insert Indication..... | 21 | +| 8.1.5 | Control Action..... | 21 | +| 8.1.6 | Policy Action..... | 21 | +| 8.2 | Common RAN Configuration Structures ..... | 21 | +| 8.2.1 | Node-Level RAN Configuration Structures..... | 22 | +| 8.2.2 | Cell-Level RAN Configuration Structures..... | 22 | +| 8.3 | RAN Configuration Structures for Event Trigger ..... | 22 | +| 8.3.1 | RAN Configuration Structures for Event Trigger Style 1..... | 22 | +| 8.3.2 | RAN Configuration Structures for Event Trigger Style 2..... | 22 | +| 8.4 | RAN Configuration Structures for Report Services ..... | 23 | +| 8.4.1 | RAN Configuration Structures for Report Service Style 1 ..... | 23 | +| 8.4.2 | RAN Configuration Structures for Report Service Style 2 ..... | 23 | +| 8.5 | RAN Configuration Structures for Insert services..... | 23 | +| 8.6 | RAN Configuration Structures for Control services..... | 23 | +| 8.6.1 | RAN Configuration Structures for Control Service Style 1 ..... | 23 | +| 8.6.2 | RAN Configuration Structures for Control Service Style 2..... | 23 | +| 8.7 | RAN Configuration Structures for Policy services..... | 23 | +| 8.7A | RAN Configuration Structures for Query services..... | 23 | +| 8.7A.1 | RAN Configuration Structures for Query Service Style 1 ..... | 23 | +| 8.7A.2 | RAN Configuration Structures for Query Service Style 2..... | 23 | +| 8.8 | Attribute Definitions ..... | 23 | +| 8.8.1 | Attribute Definitions for Node-Level RAN Configuration Structures..... | 23 | +| 8.8.2 | Attribute Definitions for Cell-Level RAN Configuration Structures..... | 26 | +| 9 | Elements for E2SM Service Model..... | 31 | +| 9.1 | General..... | 31 | +| 9.2 | Message Functional Definition and Content ..... | 31 | +| 9.2.1 | Messages for RIC Functional procedures ..... | 31 | +| 9.2.2 | Messages for RIC Global Procedures ..... | 45 | +| 9.3 | Information Element definitions ..... | 48 | +| 9.3.1 | General ..... | 48 | +| 9.3.2 | RAN Function Name..... | 49 | +| 9.3.3 | RIC Style Type..... | 49 | +| 9.3.4 | RIC Style Name ..... | 49 | +| 9.3.5 | RIC Format Type ..... | 49 | +| 9.3.6 | Cell Global ID ..... | 49 | +| 9.3.7 | RAN Configuration Structure Name..... | 49 | +| 9.3.8 | Attribute Name ..... | 49 | +| 9.3.9 | Report Type..... | 49 | +| 9.3.10 | Event Time ..... | 50 | +| 9.3.11 | Cause ..... | 50 | +| 9.3.12 | pLMNId..... | 50 | +| 9.3.13 | sNSSAI..... | 50 | +| 9.3.14 | pLMNInfo ..... | 51 | +| 9.3.15 | pLMNInfoList ..... | 51 | +| 9.3.16 | rRMPolicyMember ..... | 51 | +| 9.3.17 | rRMPolicyMemberList ..... | 51 | +| 9.3.18 | bWPList..... | 52 | +| 9.3.19 | 5QIList ..... | 52 | +| 9.3.20 | partitionFlowList..... | 52 | +| 9.3.21 | partitionList ..... | 53 | +| 9.3.22 | policyType..... | 53 | +| 9.3.23 | antennaMaskName ..... | 54 | +| 9.3.24 | antennaMask..... | 54 | +| 9.3.25 | sleepMode ..... | 55 | + +| | | | +|---------------------------------------------------------------------------|-------------------------------------------------------------------|-----------| +| 9.3.26 | dataDir ..... | 55 | +| 9.3.27 | symbolMask ..... | 55 | +| 9.3.28 | slotMask ..... | 56 | +| 9.3.29 | validDuration..... | 56 | +| 9.3.30 | esObjective..... | 56 | +| 9.3.31 | onDurationTimer..... | 57 | +| 9.3.32 | cycleStartOffset..... | 57 | +| 9.3.33 | oruUserPlaneConfiguration..... | 57 | +| 9.3.34 | txArrayList ..... | 58 | +| 9.3.35 | rxArrayList ..... | 60 | +| 9.3.36 | perfObjectiveList..... | 62 | +| 9.3.37 | oruCapabilities ..... | 63 | +| 9.3.38 | energySavingCapabilityCommonInfo..... | 63 | +| 9.3.39 | asmCapabilityInfo ..... | 63 | +| 9.3.40 | trxControlCapabilityInfo..... | 64 | +| 9.4 | JSON Schema ..... | 65 | +| 9.4.1 | General ..... | 65 | +| 9.4.2 | JSON Schema Definitions..... | 65 | +| 9.5 | Message transfer syntax..... | 88 | +| 10 | Handling of Unknown, Unforeseen and Erroneous Protocol Data ..... | 88 | +| <b>Annex A (informative): Examples on IE Contents.....</b> | | <b>88</b> | +| <b>Annex (informative): Change history/Change request (history) .....</b> | | <b>89</b> | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG3 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the E2 Service Model (E2SM) for the Near RT RIC Cell Configuration and Control. + +--- + +# 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18, or the latest 3GPP release prior to Release 18 that includes that document. + +The following referenced documents are necessary for the application of the present document. + +- [1] Void. +- [2] O-RAN.WG3.TS.E2GAP: “O-RAN E2 General Aspects and Principles (E2GAP)”. +- [3] ORAN.WG3.TS.E2AP: “O-RAN E2 Application Protocol (E2AP)”. +- [4] O-RAN.WG3.TS.E2SM: “O-RAN E2 Service Model (E2SM)”. +- [5] IETF RFC 5905 (2010-06): “Network Time Protocol Version 4: Protocol and Algorithms Specification”. +- [6] 3GPP TS 28.541 V17.9.0 (2023-01): “Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3 (Release 17)”. +- [7] 3GPP TS 38.211 V17.4.0 (2022-12): “NR; Physical channels and modulation (Release 17)”. +- [8] O-RAN.WG1.TS.OAD: “O-RAN Architecture Description (OAD)”. +- [9] O-RAN.WG4.CUS.0-R003-v14, “O-RAN Control, User and Synchronization Plane Specification”. +- [10] O-RAN.WG4.MP.0-R003-v14, “O-RAN Management Plane Specification”. +- [11] O-RAN.WG5.O-DU-O1.0-R003-v09, “O-RAN O1 Interface Specification for O-DU”. +- [12] 3GPP TS 28.552 V17.12.0 (2023-12): “Management and orchestration; 5G performance measurements (Release 17)”. +- [13] 3GPP TS 38.331: “NR; Radio Resource Control (RRC) Protocol Specification”. + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18, or the latest 3GPP release prior to Release 18 that includes that document. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +[i.1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in 3GPP TR 21.905 [i.1], O-RAN.WG1.TS.OAD [8], O-RAN.WG3.TS.E2GAP [2], O-RAN.WG3.TS.E2SM [4] and the following apply: + +Void + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply: + +| | | +|-------------|-------------------------------------------| +| O-CU | O-RAN Central Unit | +| O-CU-CP | O-RAN Central Unit – Control Plane | +| O-CU-UP | O-RAN Central Unit – User Plane | +| O-DU | O-RAN Distributed Unit | +| Near-RT RIC | Near-real-time RAN Intelligent Controller | + +# --- 4 General + +## 4.1 Procedure Specification Principles + +The principle for specifying the procedure logic is to specify the functional behaviour of the terminating node exactly and completely. Any rule that specifies the behaviour of the originating node shall be possible to be verified with information that is visible within the system. + +The following specification principles have been applied for the procedure text in clause 8: + +- The procedure text discriminates between: + +- 1) Functionality which "shall" be executed. + +The procedure text indicates that the receiving node "shall" perform a certain function Y under a certain condition. If the receiving node supports procedure X but cannot perform functionality Y requested in the REQUEST message of a Class 1 EP, the receiving node shall respond with the message used to report unsuccessful outcome for this procedure, containing an appropriate cause value. + +- 2) Functionality which "shall, if supported" be executed. + +The procedure text indicates that the receiving node "shall, if supported," perform a certain function Y under a certain condition. If the receiving node supports procedure X, but does not support functionality Y, the receiving node shall proceed with the execution of the EP, possibly informing the requesting node about the not supported functionality. + +- Any required inclusion of an optional IE in a response message is explicitly indicated in the procedure text. If the procedure text does not explicitly indicate that an optional IE shall be included in a response message, the optional IE shall not be included. For requirements on including *Criticality Diagnostics* IE, see clause 10. + +## 4.2 Forwards and Backwards Compatibility + +The forwards and backwards compatibility of the protocol is assured by a mechanism where all current and future messages, and IEs or groups of related IEs, include ID and criticality fields that are coded in a standard format that will not be changed in the future. These parts can always be decoded regardless of the standard version. + +## 4.3 Specification Notations + +For the purposes of the present document, the following notations apply: + +| | | +|----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Service | when referring to a Service in the specification the <b>SERVICE NAME</b> is written with upper case characters and in bold followed by the word "service", e.g., <b>REPORT</b> service. | +| Procedure | When referring to an elementary procedure in the specification the Procedure Name is written with the first letters in each word in upper case characters followed by the word "procedure", e.g., Handover Preparation procedure. | +| Message | When referring to a message in the specification the MESSAGE NAME is written with all letters in upper case characters followed by the word "message", e.g., HANDOVER REQUEST message. | +| IE | When referring to an information element (IE) in the specification the <i>Information Element Name</i> is written with the first letters in each word in upper case characters and all letters in <i>Italic font</i> followed by the abbreviation "IE", e.g., <i>E-RAB ID</i> IE. | +| Value of an IE | When referring to the value of an information element (IE) in the specification the "Value" is written as it is specified in the specification enclosed by quotation marks, e.g., "Value". | + +## 4.4 Void + +# --- 5 E2SM Services + +As defined in O-RAN.WG3.TS.E2GAP [2], a given RAN Function offers a set of services to be exposed over the E2 (REPORT, INSERT, CONTROL, POLICY and/or QUERY) using O-RAN.WG3.TS.E2AP [3] defined procedures. Each of the E2AP Procedures listed in table 5-1 contains specific E2 Node RAN Function dependent Information Elements (IEs) which shall be defined by a specific E2SM. + +Table 5-1: Relationship RAN Function specific E2AP Information elements and E2AP Procedures + +| RAN Function specific E2AP Information Elements | E2AP Information Element reference | Related E2AP Procedures | +|-------------------------------------------------|-------------------------------------|---------------------------------------------------| +| <i>RIC Event Trigger Definition IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.9 | RIC Subscription<br>RIC Subscription Modification | +| <i>RIC Action Definition IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.12 | RIC Subscription<br>RIC Subscription Modification | +| <i>RIC Indication Header IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.17 | RIC Indication | +| <i>RIC Indication Message IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.16 | RIC Indication | +| <i>RIC Call Process ID IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.18 | RIC Indication<br>RIC Control | +| <i>RIC Control Header IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.20 | RIC Control | +| <i>RIC Control Message IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.19 | RIC Control | +| <i>RIC Control Outcome IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.25 | RIC Control | +| <i>RIC Query Header IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.36 | RIC Query | +| <i>RIC Query Definition IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.37 | RIC Query | +| <i>RIC Query Outcome IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.38 | RIC Query | +| <i>RAN Function Definition IE</i> | O-RAN.WG3.TS.E2AP [3] clause 9.2.23 | E2 Setup<br>RIC Service Update | + +All of these RAN Function specific E2AP IEs are defined in O-RAN.WG3.TS.E2AP [3] as “OCTET STRING”. + +The purpose of this specification is to define the contents of these fields for the specific RAN function “Cell Configuration and Control”. + +# 6 RAN Function Service Model Description + +## 6.1 RAN Function Overview + +For the purposes of this E2 Service Model, E2SM-CCC, the E2 Node terminating the E2 Interface is assumed to host one or more instances of the RAN Function “Cell Configuration and Control” which performs the following functionalities: + +- E2 REPORT services used to expose node level and cell level configuration information +- E2 CONTROL services used to initiate control and/or configuration of node level and cell level parameters +- E2 QUERY services used to request and retrieve node level and cell level configuration information + +This E2SM specification provides a set of RAN Function exposure services described in clause 6.2 and has been prepared with the assumption that the same E2SM may be used to describe either a single RAN Function in the E2 Node handling all RAN cell configuration and control related processes or more than one RAN Function in the E2 Node with each instance handling a subset of the cell configuration and control related processes on the E2 Node. + +## 6.2 RAN Function exposure services + +### 6.2.1 REPORT service + +The “Cell Configuration and Control” RAN Function provides selective support of the following **REPORT** services: + +- Node level configuration information in E2 Nodes +- Cell level configuration information in E2 Nodes + +### 6.2.2 INSERT service + +Void + +### 6.2.3 CONTROL service + +The “Cell Configuration and Control” RAN Function provides selective support of the following **CONTROL** services: + +- Node level configuration and control in E2 Nodes +- Cell level configuration and control in E2 Nodes + +### 6.2.4 POLICY service + +Void + +### 6.2.5 QUERY service + +The “Cell Configuration and Control” RAN Function provides support of the following **QUERY** services: + +- Node level configuration information retrieval from E2 Nodes +- Cell level configuration information retrieval from E2 Nodes + +## 6.3 REPORT service description + +The E2SM-CCC REPORT service requirements defined in clause 6.2.1 are offered using a set of REPORT Styles. All REPORT styles are implemented using a set of IEs that constitute “Action Definition”, “RIC Indication Header” and “RIC Indication Message” to deliver “Cell Configuration and Control” related REPORT services. Each REPORT service style is associated with a specific “Event Trigger” approach. For each Report style, a single RAN Parameter table is used to specify the required information to be reported. + +The following REPORT styles are supported: + +- Node level configuration information in E2 Nodes +- Cell level configuration information in E2 Nodes + +## 6.4 INSERT service description + +Void + +## 6.5 CONTROL service description + +The E2SM-CCC CONTROL service requirements defined in clause 6.2.3 are offered using a set of CONTROL Styles. Each style corresponds to a set of “CONTROL Action”, where each “CONTROL Action” deals with a specific functionality and has a set of associated RAN parameters, provided in a mapping table. All CONTROL Service styles are implemented using a set of IEs constituting a “RIC Control Request Header” and a “RIC Control Request Message” to deliver “Cell Configuration and Control” related CONTROL services. A “CONTROL Action” containing one or more RAN parameters and their associated values can either be sent from the RIC, either asynchronously to the E2 node or as a response to a previous “INSERT Indication” from the E2 node. + +The following CONTROL styles are supported: + +- Node level configuration and control in E2 Nodes +- Cell level configuration and control in E2 Nodes + +## 6.6 POLICY service description + +Void + +## 6.7 QUERY service description + +The E2SM-CCC QUERY service requirements defined in clause 6.2.5 are offered using a set of QUERY Styles. All QUERY styles are implemented using a set of IEs for RIC Query Header, RIC Query Definition and RIC Query Outcome. For each Query style, respective RAN Configuration Structures are used to specify the required information to be requested and responded. + +# --- 7 RAN Function Description + +## 7.1 RAN Function Definition + +The E2AP [3] procedures E2 Setup and RIC Service Update are used to transport the RAN Function Description. + +For a specific RAN Function declared using E2SM-CCC, the *RAN Function Definition* IE, defined in clause 9.2.2.1 shall report the following information: + +- RAN Function name along with associated information on E2SM definition +- Event trigger styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **REPORT** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **INSERT** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **CONTROL** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **POLICY** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **QUERY** Service styles list along with the corresponding encoding type for each associated E2AP IE. + +For the case where *RAN Function Definition* IE, defined in clause 9.2.2.1, is present in the E2 SETUP REQUEST message the IE shall provide a complete list of all supported node-level RAN Configuration Structures and associated Attributes, Services including Styles, Actions and Formats along with a complete list of Cells and associated supported cell-level RAN Configuration Structures and associated Attributes, Services including Styles, Actions and Formats for all supported RIC services reflecting the current status of the RAN Function. + +For the case where *RAN Function Definition* IE, defined in clause 9.2.2.1, is present in the RIC SERVICE UPDATE message within the E2AP *RAN Functions Added List* IE, the IE shall provide a complete list of all supported node-level RAN Configuration Structures and associated Attributes, Services including Styles, Actions and Formats along with a complete list of Cells and associated supported cell-level RAN Configuration Structures and associated Attributes, Services including Styles, Actions and Formats for all supported RIC services for the newly added RAN Function with a new RAN Function ID. + +For the case where *RAN Function Definition* IE, defined in clause 9.2.2.1, is present in the RIC SERVICE UPDATE message within the E2AP *RAN Functions Modified List* IE, the IE shall provide a complete list of all supported node-level RAN Configuration Structures and associated Attributes, Services including Styles, Actions and Formats along with a complete list of Cells and associated supported cell-level RAN Configuration Structures and associated Attributes, Services including Styles, Actions and Formats for all supported RIC services including both modified and unchanged information for an existing RAN Function. + +## 7.2 RAN Function name + +RAN Function Short Name “ORAN-E2SM-CCC” + +RAN Function name description “Cell Configuration and Control” + +RAN Function Instance, required when and if E2 Node exposes more than one instance of a RAN Function based on this E2SM. + +## 7.3 Event trigger styles + +### 7.3.1 Event trigger style list + +| RIC Style Type | Style Name | Supported RIC Service Style | | | Style Description | +|----------------|------------------------------|-----------------------------|--------|--------|----------------------------------------------------------------------------------------| +| | | Report | Insert | Policy | | +| 1 | E2 Node Configuration Change | 1,2 | - | - | Triggered upon subscription and when a configuration change within the E2 Node occurs. | +| 2 | Periodic | 1,2 | - | - | Triggered in a specified period of time. | + +The details of the individual Event trigger Styles are provided in subsequent clauses. + +### 7.3.2 Event trigger style 1: E2 Node Configuration Change + +This Event trigger style is used to detect configuration changes on the subscribed E2 Node. The configuration changes can occur at node-level and/or cell-level. A node-level configuration change event occurs when addition, modification or deletion related to at least one attribute within the RAN Configuration Structures defined in clause 8.3.1 associated with the node occurs. Similarly, a cell-level configuration change event occurs when addition, modification or deletion related to at least one attribute within the RAN Configuration Structures defined in clause 8.3.2 occurs on cells within the E2 Node. The E2 Node can also be configured to detect cell-level configuration changes at a certain cell. + +The E2 Node can be configured to detect node-level or cell-level changes. The following table provides the configuration changes that are supported for event triggering along with associated RAN Configuration Structures and respective *RIC Event Trigger Definition* IE Formats. + +**Table 7.3.2-1: Event Trigger Definition Style 1 – E2 Node configuration change types, the associated RAN Configuration Structures for event triggering and respective *RIC Event Trigger Definition* IE Formats** + +| E2 Node Configuration Change Type | Associated RAN Configuration Structures | Supported RIC REPORT Service Style | <i>RIC Event Trigger Definition</i> IE Format | Description | +|-----------------------------------|-----------------------------------------|------------------------------------|-------------------------------------------------------------|--------------------------------------------------------------------------------| +| Node-level Configuration Change | 8.3.1.1 | 1 | <i>RIC Event Trigger Definition</i> IE Format 1 (9.2.1.1.1) | Triggered upon subscription and when a node-level configuration change occurs. | +| Cell-level Configuration Change | 8.3.1.2 | 2 | <i>RIC Event Trigger Definition</i> IE Format 2 (9.2.1.1.2) | Triggered upon subscription and when a cell-level configuration change occurs. | + +### 7.3.3 Event trigger style 2: Periodic + +This Event trigger style is used to trigger events within the E2 Node in a certain period of time. The following table provides the associated RAN Configuration Structures and respective *RIC Event Trigger Definition* IE Format. + +**Table 7.3.3-1: Event Trigger Definition Style 2 – Periodic type, the associated RAN Configuration Structures for event triggering and respective *RIC Event Trigger Definition IE Format*** + +| Periodic Type | Associated RAN Configuration Structures | <i>RIC Event Trigger Definition IE Format</i> | Description | +|---------------|-----------------------------------------|-------------------------------------------------------------|-----------------------------------------------------| +| Periodic | 8.3.2 | <i>RIC Event Trigger Definition IE Format 3</i> (9.2.1.1.3) | Triggered periodically in a certain period of time. | + +## 7.4 Supported RIC REPORT Services + +### 7.4.1 REPORT Service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|--------------------------|---------------------------------------------------------------------------| +| 1 | Node-Level Configuration | This style is used to report node-level E2 Node configuration information | +| 2 | Cell-Level Configuration | This style is used to report cell-level E2 Node configuration information | + +The details of the individual REPORT Service Styles are provided in subsequent clauses. + +### 7.4.2 REPORT Service Style 1: Node-Level Configuration + +#### 7.4.2.1 REPORT Service Style Description + +This **REPORT** Service style provides node-level E2 Node related configuration information. E2 Node configuration information is sent to Near-RT RIC as a RIC INDICATION message which includes the information within *RIC Indication Message IE* along with an associated *RIC Indication Header IE*. Node-level configuration information includes the RAN Configuration Structures defined in clause 8.4.1 and their attributes provided in clause 8.8.1. + +This **REPORT** Service style is initiated by Event Trigger style 1: E2 Node Configuration Change or by Event Trigger style 2: Periodic and configured using *RIC Action Definition IE*. + +#### 7.4.2.2 REPORT Service *RIC Action Definition IE* contents + +This **REPORT** Service style uses the *RIC Action Definition IE Format 1* (9.2.1.2.1). + +The supported RAN Configuration Structures for this style are provided in clause 8.4.1 and respective attributes are provided in clause 8.8.1. + +#### 7.4.2.3 REPORT Service *RIC Indication Header IE* contents + +This **REPORT** Service style uses the *RIC Indication Header IE Format 1* (9.2.1.3.1). + +#### 7.4.2.4 REPORT Service *RIC Indication Message IE* contents + +The **REPORT** Service style uses the *RIC Indication Message IE Format 1* (9.2.1.4.1). + +The supported RAN Configuration Structures for this style are provided in clause 8.4.1 and respective attributes are provided in clause 8.8.1. + +### 7.4.3 REPORT Service Style 2: Cell-Level Configuration + +#### 7.4.3.1 REPORT Service Style Description + +This **REPORT** Service style provides cell related configuration information. Cell configuration information is sent to Near-RT RIC as a RIC INDICATION message which includes the information within *RIC Indication Message* IE along with an associated *RIC Indication Header* IE. Cell configuration information includes the RAN Configuration Structures defined in clause 8.4.2 and their attributes provided in clause 8.8.2. + +This **REPORT** Service style is initiated by Event Trigger style 1: E2 Node Configuration Change or by Event Trigger style 2: Periodic and configured using *RIC Action Definition* IE. + +#### 7.4.2.2 REPORT Service *RIC Action Definition* IE contents + +This **REPORT** Service style uses the *RIC Action Definition* IE Format 2 (9.2.1.2.2). + +The supported RAN Configuration Structures for this style are provided in clause 8.4.2 and respective attributes are provided in clause 8.8.2. + +#### 7.4.2.3 REPORT Service *RIC Indication Header* IE contents + +This **REPORT** Service style uses the *RIC Indication Header* IE Format 1 (9.2.1.3.1). + +#### 7.4.2.4 REPORT Service *RIC Indication Message* IE contents + +The **REPORT** Service style uses the *RIC Indication Message* IE Format 2 (9.2.1.4.2). + +The supported RAN Configuration Structures for this style are provided in clause 8.4.2 and respective attributes are provided in clause 8.8.2. + +## 7.5 Supported RIC INSERT Services + +Void + +## 7.6 Supported RIC CONTROL Services + +### 7.6.1 CONTROL Service Style Types + +| RIC Style Type | Style Name | Style Description | +|----------------|--------------------------------|---------------------------------------------------------------------| +| 1 | Node Configuration and Control | Used to perform node-level configuration and control at the E2 Node | +| 2 | Cell Configuration and Control | Used to perform cell-level configuration and control at the E2 Node | + +The details of the individual Control Service Styles are provided in subsequent clauses + +### 7.6.2 CONTROL Service Style 1: Node Configuration and Control + +#### 7.6.2.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to modify RAN configuration (based on various triggers, such as the receipt of an A1 policy enforcement or detection of slice SLA violation conditions) at the E2 Node using the *RIC Control Header* IE and *RIC Control Message* IE. + +#### 7.6.2.2 CONTROL Service *RIC Control Header* IE contents + +This **CONTROL** style uses *RIC Control Header* IE Format 1 (9.2.1.6.1). + +#### 7.6.2.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** style uses *RIC Control Message* IE Format 1 (9.2.1.7.1). + +#### 7.6.2.4 CONTROL Service *RIC Call Process ID* IE contents + +Void + +#### 7.6.2.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a transparent container that is used to carry the outcome of processing the incoming *RIC Control Request* message. + +This **CONTROL** style uses *RIC Control Outcome* IE Format 1 (9.2.1.8.1). + +### 7.6.3 CONTROL Service Style 2: Cell Configuration and Control + +#### 7.6.3.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to modify RAN configuration (based on various triggers, such as the receipt of an A1 policy enforcement or detection of slice SLA violation conditions) at the cells of the E2 Node using the *RIC Control Header* IE and *RIC Control Message* IE. + +#### 7.6.3.2 CONTROL Service *RIC Control Header* IE contents + +This **CONTROL** style uses *RIC Control Header* IE Format 1 (9.2.1.6.1). + +#### 7.6.3.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** style uses *RIC Control Message* IE Format 2 (9.2.1.7.2). + +#### 7.6.3.4 CONTROL Service *RIC Call Process ID* IE contents + +Void + +#### 7.6.3.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a transparent container that is used to carry the outcome of processing the incoming *RIC Control Request* message. + +This **CONTROL** style uses *RIC Control Outcome* IE Format 2 (9.2.1.8.2). + +## 7.7 Supported RIC POLICY Services + +Void + +## 7.7A Supported RIC QUERY Services + +### 7.7A.1 QUERY Service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|--------------------------------|---------------------------------------------------------------------------| +| 1 | Node-Level Configuration Query | Used to request and get response for node-level configuration information | +| 2 | Cell-Level Configuration Query | Used to request and get response for cell-level configuration information | + +### 7.7A.2 QUERY Service Style 1: Node-Level Configuration Query + +#### 7.7A.2.1 QUERY Service Style description + +This **QUERY** Service style is used to request node level related configuration data related to E2 Node by Near-RT RIC. E2 Node shall use this service style to respond to the requested information from Near-RT RIC. + +#### 7.7A.2.2 QUERY Service *RIC Query Header* IE contents + +This **QUERY** Service style uses the *E2SM-CCC Query Header Format 1* IE (9.2.1.9.1). + +#### 7.7A.2.3 QUERY Service *RIC Query Definition* IE contents + +The RIC Query Definition for this service style indicates the information type requested by Near-RT RIC. + +The **QUERY** Service style uses the *E2SM-CCC Query Definition Format 1* IE (9.2.1.10.1). The supported RAN configuration structures for this format are provided in clause 8.9.1. + +#### 7.7A.2.4 QUERY Service *RIC Query Outcome* IE contents + +This **QUERY** Service style uses the *E2SM-CCC Query Outcome Format 1* IE (9.2.1.11.1). The mapping of RAN Configuration Structures configured in the *RIC Query Definition* IE to the reported IEs in the *E2SM-CCC Query Outcome Format 1* IE is provided in the semantics description of the IEs. + +### 7.7A.3 QUERY Service Style 2: Cell-Level Configuration Query + +#### 7.7A.3.1 QUERY Service Style description + +This **QUERY** Service style is used to request node level related configuration data related to E2 Node by Near-RT RIC. E2 Node shall use this service style to respond to the requested information from Near-RT RIC. + +#### 7.7A.3.2 QUERY Service *RIC Query Header* IE contents + +This **QUERY** Service style uses the *E2SM-CCC Query Header Format 1* IE (9.2.1.9.1). + +#### 7.7A.3.3 QUERY Service *RIC Query Definition* IE contents + +The RIC Query Definition for this service style indicates the information type requested by Near-RT RIC. + +The **QUERY** Service style uses the *E2SM-CCC Query Definition Format 2* IE (9.2.1.10.2). The supported RAN configuration structures for this format are provided in clause 8.9.2. + +#### 7.7A.3.4 QUERY Service RIC Query Outcome IE contents + +This **QUERY** Service style uses the *E2SM-CCC Query Outcome Format 2* IE (9.2.1.11.2). The mapping of RAN Configuration Structures configured in the *RIC Query Definition* IE to the reported IEs in the *E2SM-CCC Query Outcome Format 2* IE is provided in the semantics description of the IEs. + +## 7.8 Supported RIC Service Styles and E2SM IE Formats + +Table 7.8-1 and 7.8-2 provide a summary of the E2SM IE Formats defined to support this E2SM specification. + +**Table 7.8-1: Summary of the E2SM IE Formats defined to support RIC Event Trigger Styles** + +| RIC Event Trigger Style | Event Trigger Definition Format | +|-------------------------|---------------------------------| +| Style 1 | 1, 2 | +| Style 2 | 3 | + +**Table 7.8-2: Summary of the E2SM IE Formats defined to support RIC Service Styles** + +| RIC Service Style | Action Definition Format | Indication Header Format | Indication Message Format | Call Process ID Format | Control Header Format | Control Message Format | Control Outcome Format | +|-------------------|--------------------------|--------------------------|---------------------------|------------------------|-----------------------|------------------------|------------------------| +| <b>REPORT</b> | | | | | | | | +| Style 1 | 1 | 1 | 1 | | | | | +| Style 2 | 2 | 1 | 2 | | | | | +| | | | | | | | | +| <b>INSERT</b> | | | | | | | | +| | | | | | | | | +| <b>CONTROL</b> | | | | | | | | +| Style 1 | | | | | 1 | 1 | 1 | +| Style 2 | | | | | 1 | 2 | 2 | +| | | | | | | | | +| <b>POLICY</b> | | | | | | | | +| | | | | | | | | + +**Table 7.8-3: Summary of the E2SM IE Formats defined to support RIC Service Styles** + +| RIC Service Style | Query Header Format | Query Definition Format | Query Outcome Format | +|-------------------|---------------------|-------------------------|----------------------| +| <b>QUERY</b> | | | | +| Style 1 | 1 | 1 | 1 | +| Style 2 | 1 | 2 | 2 | + +# 8 RAN Configuration Structures + +## 8.1 Approach + +The RAN Configuration Structures associated with each RIC Service described in clause 7 are listed here in clause 8. RAN Configuration Structures are groupings of RAN configuration attributes, which can either be based on the NRM definitions in 3GPP TS 28.541 [6] where applicable or extended / newly introduced by O-RAN specifications. RAN Configuration Structures and their corresponding set of attributes are used by the E2SM-CCC RIC services. + +The following clauses introduce E2SM-CCC RAN Configuration Structures and their attributes as well as the necessary information to enable their support in each RIC service. Clause 8.8 provides the definitions for each RAN Configuration Structure and its respective attributes. The attributes of RAN Configuration Structures which are based on 3GPP NRM definitions include respective 3GPP standard definitions of these RAN configuration structure attributes as referenced in the tables below under the “Semantics Description” column. These attributes, which have 3GPP standard definitions, are not freshly defined or redefined in this specification. + +The attributes, whose corresponding value in the “Is Writable” column in the configuration structure is FALSE, shall not be modified by the Near-RT RIC; however, such attributes shall serve as a reference to other attributes, which are bound to the same configuration structure. + +For e.g., in the RAN configuration structure O-RRMPolicyRatio (in clauses 8.8.1.4 and 8.8.2.4), the value of the “Is Writable” field for the *resourceType* attribute is FALSE since the *resourceType* IE indicates the type of the RRM policy resource, which could be a) PRB DL or PRB UL for the O-NRCellDU defined in clause 8.8.2.2 or the O-GNBDUFunction defined in clause 8.8.1.1 or b) number of RRC connected UEs for the O-NRCellCU defined in clause 8.8.2.1 or the O-GNBCUCPFunction defined in clause 8.8.1.2 or c) the DRB for the O-GNBCUUPFunction defined in clause 8.8.1.3. Therefore, the attribute value for the *resourceType* IE cannot be modified by the Near-RT RIC, but can be used within the RIC CONTROL Service for other purposes (e.g., serving as a reference to the other attributes; *rRMPolicyMaxRatio*, *rRMPolicyMinRatio*, *rRMPolicyDedicatedRatio*, *rRMPolicyMemberList* within the structure O-RRMPolicyRatio for any given instance of the RAN configuration structure). + +### 8.1.1 RIC Event Trigger Definition + +Node-level and cell-level event triggers can be configured periodically or upon a configuration change within the E2 Node based on the RAN Configuration Structures defined in clause 8.3. In the E2 node RAN function “CCC”, there can be one or more instances of these RAN configuration structures, where a local copy of the attributes for each instance shall be maintained for modifying and managing their values. If Near-RT RIC subscribes to periodic events (see event trigger style 2 defined in clause 7.3.3), the RAN function “CCC” in the E2 node shall trigger events in a certain period defined in the *RIC Event Trigger Definition* IE. On the other hand, if Near-RT RIC subscribes to E2 configuration changes (see event trigger style 1 defined in clause 7.3.2), the RAN function “CCC” in the E2 node shall trigger an event upon subscription and when the specified list of the configuration attributes pertaining to any instance of the RAN configuration structures (listed here in clause 8), provided by the Near-RT RIC in the *RIC Event Trigger Definition* IE, undergoes a change (e.g. modification in its value). If the list of configuration attributes is not provided for any RAN configuration structure by the Near-RT RIC in the *RIC Event Trigger Definition* IE, then the RAN function “CCC” in the E2 node shall trigger an event when any attribute in the listed configuration structures in the *RIC Event Trigger Definition* IE undergoes a change. This change in the value of the configuration attribute can be caused either by an internal operation in the E2 node or due to a management operation carried out by a management function (such as the SMO) over a management interface (such as O1) or a dSON operation, etc. + +An example use case for configuration change event triggers is when O-RRMPolicyRatio RAN configuration structure is used for managing radio resources for two different slices (e.g., eMBB and URLLC) in the same NR Cell. In this case, there will be two instances of the O-RRMPolicyRatio (in clause 8.8.2.4) created for the same NR Cell, with one instance (e.g., O-RRMPolicyRatio\_PRB\_1) used for managing PRB resource allocation of the eMBB slice and another instance (e.g., O-RRMPolicyRatio\_PRB\_2) used for managing the PRB resource allocation of the URLLC slice of the same NR Cell. During subscription, if the Near-RT RIC includes O-RRMPolicyRatio in the *RAN Configuration Structure Name* IE under the *List of RAN Configuration Structures* IE corresponding to the NR Cell in the *RIC Event Trigger Definition* IE (clause 9.2.1.1.2) and includes *rRMPolicyMinRatio* attribute and *rRMPolicyMaxRatio* attribute for the *Attribute Name* IE under the *List of Attributes* IE in the *RIC Event Trigger Definition* IE, then the RAN function “CCC” in the E2 node shall trigger the RIC event whenever *rRMPolicyMinRatio* attribute or *rRMPolicyMaxRatio* attribute changes in O-RRMPolicyRatio\_PRB\_1 for the NR cell and/or whenever any of these attributes change in O-RRMPolicyRatio\_PRB\_2 for the same NR cell. + +In the E2 node, the RAN function “CCC” shall also trigger an event in case of other configuration changes pertaining to the node or the cells, such as creation of a new instance or deletion of an existing instance of any configuration structure (listed here in clause 8), as specified by the Near-RT RIC in the *RIC Event Trigger Definition* IE. + +Examples include triggering an event in the E2 node when a new instance of the O-NRCellCU is created, which happens whenever a new NR cell is added to the E2 node, or triggering an event in the E2 node when a new instance of the O-BWP is created, which happens whenever a new bandwidth part (BWP) is added to the NR cell, given by the *Global Cell Id* IE (in clause 9.2.1.1.2), in the E2 node. Additional examples include triggering an event in the E2 node when an existing instance of the O-RRMPolicyRatio is deleted, which happens when an existing RRM policy pertaining to the E2 node (related to the RRC connected users for the O-CU-CP E2 node or the DRB policy for the O-CU-UP E2 node) is deleted. + +### 8.1.2 RIC Action Definition + +When an event is triggered by the RAN function “CCC” within the E2 node pertaining to one or more RAN configuration structures, the RAN function “CCC” in the E2 Node shall execute the actions as defined in *RIC Action Definition* IE in clause 9.2.1.2. + +Using E2SM-CCC Action Definition Formats 1 and 2 (clauses 9.2.1.2.1 and 9.2.1.2.2), the Near-RT RIC shall specify which RAN configuration structures and which attributes pertaining to these structures shall have to be reported, when the corresponding event is triggered in the E2 node. The requested RAN configuration structures are provided in the *RAN Configuration Structure Name* IE listed under the *List of Node-level Configuration Structures* IE in clause 9.2.1.2.1 or under the *List of Cell-level Configuration Structures* IE in clause 9.2.1.2.2. The requested attributes for that specific RAN configuration structure are provided in *List of Attributes* IE. + +When the *Report Type* IE is ‘All’, then the E2 node shall generate a report indication action involving every instance of the respective RAN configuration structure whether there has been a configuration change (addition/deletion/modification, as discussed in clause 8.1.1) or not. If the *List of Attributes* IE is not included in the *RIC Action Definition* IE, then the E2 node shall report the attribute-value pair for all the attributes defined within the respective RAN configuration structure, pertaining to each instance of the configuration structure; whereas, if the *List of Attributes* IE is included in the *RIC Action Definition* IE, then the E2 node shall only report the attribute-value pair for the specific list of attributes within the respective RAN configuration structure, pertaining to each instance of the configuration structure. + +When the *Report Type* IE is ‘Change’, then the E2 node shall generate a report indication action involving only those instances of the respective RAN configuration structure that underwent a configuration change among all. Depending on the inclusion of *List of Attributes* IE, all or specified list of attribute-value pairs shall be present for those changed RAN configuration structure instances. Finally, when *Global Cell Id* IE is present, then the reporting shall be done only for the specified cell(s). + +For e.g., An NR Cell has two instances of O-RRMPolicyRatio configuration structure, namely O-RRMPolicyRatio\_PRB\_1 and O-RRMPolicyRatio\_PRB\_2, for managing the RRM policy ratio of PRB allocation in the cell for eMBB and URLLC slices, respectively. The RIC Event Trigger Definition IE is defined such that the event must be triggered when the rRMPolicyMinRatio attribute of any instance, O-RRMPolicyRatio\_PRB\_1 and/or O-RRMPolicyRatio\_PRB\_2, undergoes a change. The following cases present details of how the E2 node shall generate the report actions for different RIC Action Definition IE contents, for this example. + +Case 1: In the *RIC Action Definition* IE, *Cell Global ID* IE of the NR Cell is specified (clause 9.2.1.2.2), *Report Type* IE is ‘All’ and *List of Attributes* IE is not included, and the instance O-RRMPolicyRatio\_PRB\_1 underwent a configuration change. In this case, the E2 node shall generate a report action including both the instances, O-RRMPolicyRatio\_PRB\_1 and O-RRMPolicyRatio\_PRB\_2 (irrespective of whether any of their attributes has changed or not) within the *List of Configuration Structures Reported* IE and include all attribute-value pairs as defined in clause 8.8.2.4, in respective IEs; For the unchanged O-RRMPolicyRatio instance(s), i.e. O-RRMPolicyRatio\_PRB\_2, current values for all attributes shall be present in *Values of Attributes* IE whereas for the modified O-RRMPolicyRatio instance(s), i.e. O-RRMPolicyRatio\_PRB\_1, in addition to reporting the current values for all attributes in *Values of Attributes* IE, the old values of all attributes shall be reported in *Old Values of Attributes* IE. + +Case 2: In the RIC Action Definition IE, Cell Global ID IE of the NR Cell is specified (clause 9.2.1.2.2), Report Type IE is ‘All’ and List of Attributes IE is mentioned in the RIC Action Definition IE and includes the resourceType, rRMPolicyMemberList, rRMPolicyMinRatio, and the rRMPolicyMaxRatio attribute. In this case, again the E2 node shall generate a report action including both the instances, O-RRMPolicyRatio\_PRB\_1 and O-RRMPolicyRatio\_PRB\_2 (irrespective of whether any of their attributes has changed or not) within List of Configuration Structures Reported IE, but shall now include only the resourceType, rRMPolicyMemberList, rRMPolicyMinRatio, rRMPolicyMaxRatio attribute-value pairs in respective IEs since only those attributes are listed to be reported in the List of Attributes IE. For the unchanged O-RRMPolicyRatio instance(s), i.e., O-RRMPolicyRatio\_PRB\_2, current values for these four attributes shall be present in Values of Attributes IE whereas, for the modified O-RRMPolicyRatio instance(s), i.e., O-RRMPolicyRatio\_PRB\_1, in addition to reporting the current values for these four attributes in Values of Attributes IE, the old values of these four attributes shall be reported in Old Values of Attributes IE. + +Case 3: In the RIC Action Definition IE, Cell Global ID IE of the NR Cell is specified (clause 9.2.1.2.2), Report Type IE is ‘Change’ and List of Attributes IE is not included. In this case the E2 node shall generate a report indication action only involving the changed instance of O-RRMPolicyRatio, i.e., O-RRMPolicyRatio\_PRB\_1, within the List of Configuration Structures Reported IE and include all attribute-value pairs as defined in clause 8.8.2.4 for the instance O-RRMPolicyRatio\_PRB\_1, reporting the current values for all attributes in Values of Attributes IE and reporting the old values of all attributes for the same instance in Old Values of Attributes IE. + +Case 4: In the RIC Action Definition IE, Cell Global ID IE of the NR Cell is specified (clause 9.2.1.2.2), Report Type IE is ‘Change’ and List of Attributes IE is mentioned in the RIC Action Definition IE and includes the resourceType, rRMPolicyMemberList, rRMPolicyMinRatio, and the rRMPolicyMaxRatio attribute. In this case again the E2 node shall generate a report indication action only involving the changed instance(s) of O-RRMPolicyRatio, i.e., O-RRMPolicyRatio\_PRB\_1, within the List of Configuration Structures Reported IE, but shall now include only the resourceType, rRMPolicyMemberList, rRMPolicyMinRatio, rRMPolicyMaxRatio attribute-value pairs in respective IEs since only those attributes are listed to be reported in the List of Attributes IE. The E2 Node shall report current values for these four attributes for the instance O-RRMPolicyRatio\_PRB\_1 in Values of Attributes IE and shall report the old values of these four attributes for the same instance in Old Values of Attributes IE. + +The details of the approach for the Report Indication action, Insert Indication action and the Policy action are discussed in clauses 8.1.3, 8.1.4 and 8.1.6, respectively. + +### 8.1.3 Report Indication + +When the E2 node executes a Report Indication action, it shall report the attribute-value pairs for the relevant list of attributes (as detailed in clause 8.1.2 and clause 9.2.1.2) from the instances of the configuration structures. The *Change Type* IE provided by the E2 Node in the *RIC Indication Message* IE (clauses 9.2.1.4.1 and 9.2.1.4.2) corresponds to the type of the event. As discussed in clause 7.3 and clause 8.1.1, the RAN function “CCC” in the E2 node shall generate events by any of the following triggers: modification in the value of the configuration attributes in the instances of the configuration structures (*Change Type* IE is ‘Modification’), addition of new instances of configuration structures pertaining to the E2 nodes or the cells (*Change Type* IE is ‘Addition’), deletion of existing instances of configuration structures pertaining to E2 nodes or cells (*Change Type* IE is ‘Deletion’), upon subscription, and/or periodic timer events (*Change Type* IE is ‘None’). + +In case of attribute-value modifications within the E2 Node, then the E2 node shall report the attribute-value pairs for the list of attributes (specified in the *RIC Action Definition* IE) before the modification as well as after the modification using the *Old Values of Attributes* IE and the *Values of Attributes* IE, respectively (*Change Type* IE is ‘Modification’). These IEs contain the structure of the attribute-value pairs for the relevant list of attributes. Since there can be multiple instances for any RAN configuration structure (as detailed in clause 8.1.1) pertaining to the E2 nodes or cells, the E2 node shall include both the *Old Values of Attributes* IE as well as the *Values of Attributes* IE in order to enable the Near-RT RIC to discover the correct instances of the configuration structures, for which the E2 node reports the relevant list of attribute-value pairs. + +For illustrative purposes, the example O-RRMPolicyRatio use case presented in clause 8.1.1 can be used again where there are 2 instances of the O-RRMPolicyRatio RAN configuration structure, namely O-RRMPolicyRatio\_PRB\_1 and O-RRMPolicyRatio\_PRB\_2, that are used for managing PRB resource allocation of the eMBB and URLLC slices in the same NR Cell. When the RIC event trigger is caused due to modification in the values of O-RRMPolicyRatio\_PRB\_1, if the *RIC Action Definition* IE includes the *Report Type* IE whose value is set to ‘All’ and the *List of Attributes* IE which includes the *resourceType*, *rRMPolicyMemberList*, *rRMPolicyMinRatio*, and *rRMPolicyMaxRatio* attributes, then the E2 node shall report these four attributes for both O-RRMPolicyRatio\_PRB\_1 and O-RRMPolicyRatio\_PRB\_2. + +For O-RRMPolicyRatio\_PRB\_1, the E2 node shall report the value of *ChangeType* IE as ‘Modification’ and report old values for *resourceType*, *rRMPolicyMemberList*, *rRMPolicyMinRatio*, *rRMPolicyMaxRatio* attributes (before modification) for the eMBB slice served by the NR Cell in the *Old Value of Attributes* IE and shall report the new values for these attributes in the *Value of Attributes* IE. However, for O-RRMPolicyRatio\_2, the E2 node shall report the value of *ChangeType* IE as ‘None’ and the current values of the *resourceType*, *rRMPolicyMemberList*, *rRMPolicyMinRatio*, *rRMPolicyMaxRatio* attributes for O-RRMPolicyRatio\_PRB\_2, pertaining to the uRLLC slice served by the same cell, shall be reported in the *Value of Attributes* IE in the E2SM-CCC *RIC Indication message* IE contents since there has been no modification in O-RRMPolicyRatio\_PRB\_2. + +This reporting of attribute-value pairs for the list of attributes in both the *Old Value of Attributes* IE and the *Value of Attributes* IE, in the case of modification, enables the Near-RT RIC to discover the correct instance of the RAN configuration structure, when there is more than one instance of the same RAN configuration structure assuming key attributes are configured to be present in Report Indication action which depends on the use case and the RAN configuration structure. In order to guarantee identification of the correct instance within the Near-RT RIC in all cases, during subscription Near-RT RIC should not include *List of Attributes IE* in *RIC Action Definition* IE for all attributes to be reported in RIC Indication. + +As another example, when a new instance of the O-RRMPolicyRatio RAN configuration structure is created (e.g., O-RRMPolicyRatio\_DRB\_3) due to the creation of a new RRM policy for the resource type DRB, within the E2 node O-CU-UP, and when the *RIC Action Definition* IE includes the *Report Type* IE whose value is set to ‘Change’ and the *List of Attributes* IE, which includes the *resourceType*, *rRMPolicyMemberList*, *rRMPolicyMinRatio*, *rRMPolicyMaxRatio* attributes, then the E2 node shall report the value of *ChangeType* IE as ‘Addition’ and shall report the attribute-value pair of all these attributes in the *Value* + +of *Attributes* IE. Since the configuration change is not due to modification in the value of an attribute but due to the creation of a new O-RRMPolicyRatio in the E2 node, the E2 node shall not report the *Old Value of Attributes* IE. Likewise, if an instance of the O-RRMPolicyRatio RAN configuration structure is deleted, then the E2 node shall report the value of *ChangeType* IE as 'Deletion' and shall only report the attribute-value pair of all these attributes in the *Value of Attributes* IE pertaining to the deleted O-RRMPolicyRatio instance. + +### 8.1.4 Insert Indication + +Void + +### 8.1.5 Control Action + +When the Near-RT RIC executes a control action, it shall provide the attribute-value pairs for the list of attributes that the Near-RT RIC shall control for the instances of the RAN configuration structures. The Near-RT RIC shall specify the RAN configuration structures that it controls using the *RAN Configuration Structure Name* IE (in *RIC Control Message* IE, specified in clause 9.2.1.7) under the *List of Configuration Structures* IE for the E2 node or for the list of cells specified using the *List of Cells* IE (in clause 9.2.1.7.2). + +For each RAN configuration structure, the Near-RT RIC shall include the *Old Values of Attributes* IE and the *New Values of Attributes* IE. These IEs contain the structure of the attribute-value pairs for the entire list of attributes of the configuration structures that the Near-RT RIC shall control on the E2 nodes. Since there can be multiple instances for any RAN configuration structure (as detailed in clause 8.1.1) pertaining to the E2 nodes or cells that the Near-RT RIC controls, the Near-RT RIC shall include both the *Old Values of Attributes* IE as well as the *New Values of Attributes* IE in order to enable the E2 node to determine the correct instances of the RAN configuration structures for which the values of the attributes shall be modified by the RIC. + +The RAN function "CCC" in the E2 node shall determine the correct instances of the RAN configuration structures using the *Old Values of Attributes* IE containing the current attribute-value pairs and replace them with the attribute-value pairs in the *New Values of Attributes* IE, as specified by the Near-RT RIC, for those instances. + +As an example, similar to the O-RRMPolicyRatio use case presented in clause 8.1.1 where there are 2 instances of the O-RRMPolicyRatio RAN configuration structure, namely O-RRMPolicyRatio\_PRB\_1 and O-RRMPolicyRatio\_PRB\_2, the Near-RT RIC can control PRB resource allocation for these eMBB and URLLC slices in the same NR Cell by utilizing the RIC CONTROL Service. In order to do so, the Near-RT RIC shall modify the values of the O-RRMPolicyRatio attributes (e.g., *rRMPolicyMinRatio*, *rRMPolicyMaxRatio*, *rRMPolicyDedicatedRatio*) for O-RRMPolicyRatio\_PRB\_1 and O-RRMPolicyRatio\_PRB\_2 for the same NR cell (of type O-NRCellDU). For each O-RRMPolicyRatio instance, the Near-RT RIC shall first include the old values of the respective O-RRMPolicyRatio attributes (*resourceType*, *rRMPolicyMemberList*, *rRMPolicyMinRatio*, *rRMPolicyMaxRatio*, *rRMPolicyDedicatedRatio*) of the NR cell in the *Old Value of Attributes* IE. Second, the Near-RT RIC shall include all the unchanged and new values of the respective O-RRMPolicyRatio attributes requested by the Near-RT RIC that the E2 node shall replace with, in the *New Value of Attributes* IE. When there is more than one instance of the RAN configuration structure (e.g. O-RRMPolicyRatio\_PRB\_1 and O-RRMPolicyRatio\_PRB\_2 in this example scenario), the E2 node shall determine the correct instance of the RAN configuration structure from the attribute-value pairs included in the list of attributes in both the *Old Value of Attributes* IE and the *New Value of Attributes* IE to be able to modify the correct instance and its respective attribute values. + +### 8.1.6 Policy Action + +Void + +## 8.2 Common RAN Configuration Structures + +The configuration structures, referencing the corresponding attributes, that can be commonly used across multiple service styles are listed here. + +### 8.2.1 Node-Level RAN Configuration Structures + +| RAN Configuration Structure Name | RAN Configuration Structure Definition | Semantics Description | +|----------------------------------|----------------------------------------|-------------------------------------------------------------| +| O-GNBDUFunction | 8.8.1.1 | Represents O-GNBDUFunction attributes defined in 8.8.1.1. | +| O-GNBCUCPFunction | 8.8.1.2 | Represents O-GNBCUCPFunction attributes defined in 8.8.1.2. | +| O-GNBCUUPFunction | 8.8.1.3 | Represents O-GNBCUUPFunction attributes defined in 8.8.1.3. | +| O-RRMPolicyRatio | 8.8.1.4 | Represents O-RRMPolicyRatio attributes defined in 8.8.1.4. | + +### 8.2.2 Cell-Level RAN Configuration Structures + +| RAN Configuration Structure Name | RAN Configuration Structure Definition | Semantics Description | +|----------------------------------|----------------------------------------|-------------------------------------------------------------------| +| O-NRCellCU | 8.8.2.1 | Represents O-NRCellCU attributes defined in 8.8.2.1. | +| O-NRCellDU | 8.8.2.2 | Represents O-NRCellDU attributes defined in 8.8.2.2. | +| O-BWP | 8.8.2.3 | Represents O-BWP attributes defined in 8.8.2.3. | +| O-RRMPolicyRatio | 8.8.2.4 | Represents O-RRMPolicyRatio attributes defined in 8.8.2.4. | +| O-CESManagementFunction | 8.8.2.5 | Represents O-CESManagementFunction attributes defined in 8.8.2.5. | +| O-NESPolicy | 8.8.2.6 | Represents O-NESPolicy attributes defined in 8.8.2.6. | +| O-CellIDTXDRXConfig | 8.8.2.7 | Represents O-CellIDTXDRXConfig attributes defined in 8.8.2.7. | +| O-RUInfo | 8.8.2.8 | Represents the O-RUInfo attributes defined in 8.8.2.8. | + +## 8.3 RAN Configuration Structures for Event Trigger + +### 8.3.1 RAN Configuration Structures for Event Trigger Style 1 + +#### 8.3.1.1 RAN Configuration Structures for Node-level Configuration Change + +Common node-level RAN Configuration Structures defined in clause 8.2.1 shall be used when defining event triggers. + +#### 8.3.1.2 RAN Configuration Structures for Cell-level Configuration Change + +Common cell-level RAN Configuration Structures defined in clause 8.2.2 shall be used when defining event triggers. + +### 8.3.2 RAN Configuration Structures for Event Trigger Style 2 + +Common node-level and cell-level RAN Configuration Structures defined in clauses 8.2.1 and 8.2.2 shall be used when defining event triggers. + +## 8.4 RAN Configuration Structures for Report Services + +### 8.4.1 RAN Configuration Structures for Report Service Style 1 + +Common node-level RAN Configuration Structures defined in clause 8.2.1 shall be used for REPORT Service Style 1. + +### 8.4.2 RAN Configuration Structures for Report Service Style 2 + +Common cell-level RAN Configuration Structures defined in clause 8.2.2 shall be used for REPORT Service Style 2. + +## 8.5 RAN Configuration Structures for Insert services + +Void + +## 8.6 RAN Configuration Structures for Control services + +### 8.6.1 RAN Configuration Structures for Control Service Style 1 + +Common node-level RAN Configuration Structures defined in clause 8.2.1 shall be used for CONTROL Service Style 1. + +### 8.6.2 RAN Configuration Structures for Control Service Style 2 + +Common cell-level RAN Configuration Structures defined in clause 8.2.2 shall be used for CONTROL Service Style 2. + +## 8.7 RAN Configuration Structures for Policy services + +Void + +## 8.7A RAN Configuration Structures for Query services + +### 8.7A.1 RAN Configuration Structures for Query Service Style 1 + +Common node-level RAN Configuration Structures defined in clause 8.2.1 shall be used for QUERY Service Style 1. + +### 8.7A.2 RAN Configuration Structures for Query Service Style 2 + +Common cell-level RAN Configuration Structures defined in clause 8.2.2 shall be used for QUERY Service Style 2. + +## 8.8 Attribute Definitions + +### 8.8.1 Attribute Definitions for Node-Level RAN Configuration Structures + +#### 8.8.1.1 O-GNBDUFunction + +The E2 node O-DU is represented by the O-GNBDUFunction configuration structure. + +| IE/Group Name | Supported Services | Is writable | IE type and reference | Semantics description | +|---------------|--------------------|-------------|---------------------------------|-----------------------------------------------------------| +| gNBDUId | REPORT | FALSE | INTEGER (0..2 <sup>36</sup> -1) | Please refer to [6] clause 4.4.1, “gNBDUId” attribute | +| gNBDUName | REPORT | FALSE | STRING | Please refer to [6] clause 4.4.1, “gNBDUName” attribute | +| gNBId | REPORT | FALSE | INTEGER (0..4294967295) | Please refer to [6] clause 4.4.1, “gNBId” attribute | +| gNBIdLength | REPORT | FALSE | INTEGER (22..32) | Please refer to [6] clause 4.4.1, “gNBIdLength” attribute | + +#### 8.8.1.2 O-GNBCUCPFunction + +The E2 node O-CU-CP is represented by the O-GNBCUCPFunction configuration structure. + +| IE/Group Name | Supported Services | Is writable | IE type and reference | Semantics description | +|---------------|--------------------|-------------|-------------------------|----------------------------------------------------------------------| +| gNBId | REPORT, CONTROL | FALSE | INTEGER (0..4294967295) | Please refer to [6] clause 4.4.1, “gNBId” attribute | +| gNBIdLength | REPORT, CONTROL | FALSE | INTEGER (22..32) | Please refer to [6] clause 4.4.1, “gNBIdLength” attribute | +| gNBCUName | REPORT, CONTROL | FALSE | STRING | Please refer to [6] clause 4.4.1, “gNBCUName” attribute | +| pLMNId | REPORT, CONTROL | FALSE | 9.3.12 | Please refer to [6] clause 4.4.1, “GNBCUCPFunction.pLMNId” attribute | +| x2BlockList | REPORT, CONTROL | TRUE | STRING | Please refer to [6] clause 4.4.1, “x2BlockList” attribute | +| x2AllowList | REPORT, CONTROL | TRUE | STRING | Please refer to [6] clause 4.4.1, “x2AllowList” attribute | +| xnBlockList | REPORT, CONTROL | TRUE | STRING | Please refer to [6] clause 4.4.1, “xnBlockList” attribute | +| xnAllowList | REPORT, CONTROL | TRUE | STRING | Please refer to [6] clause 4.4.1, “xnAllowList” attribute | +| x2HOBLOCKList | REPORT, CONTROL | TRUE | STRING | Please refer to [6] clause 4.4.1, “x2HOBLOCKList” attribute | +| xnHOBLOCKList | REPORT, CONTROL | TRUE | STRING | Please refer to [6] clause 4.4.1, “xnHOBLOCKList” attribute | + +#### 8.8.1.3 O-GNBCUUPFunction + +The E2 node O-CU-UP is represented by the O-GNBCUUPFunction configuration structure. + +| IE/Group Name | Supported Services | Is writable | IE type and reference | Semantics description | +|---------------|--------------------|-------------|---------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| gNBId | REPORT | FALSE | INTEGER (0..4294967295) | Please refer to [6] clause 4.4.1, “gNBId” attribute | +| gNBIdLength | REPORT | FALSE | INTEGER (22..32) | Please refer to [6] clause 4.4.1, “gNBIdLength” attribute | +| gNBCUUPId | REPORT | FALSE | INTEGER (0..2 <sup>36</sup> -1) | Please refer to [6] clause 4.4.1, “gNBCUUPId” attribute | +| plMNInfoList | REPORT | FALSE | 9.3.15 | The PLMNInfoList is a list of PLMNInfo data type. It defines which PLMNs that can be served by the GNBCUUPFunction [6] and which S-NSSAIs can be supported by the GNBCUUPFunction [6] for corresponding PLMN in case of network slicing feature is supported. | + +#### 8.8.1.4 O-RRMPolicyRatio + +| IE/Group Name | Supported Services | Is writable | IE type and reference | Semantics description | +|-------------------------|--------------------|-------------|---------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| resourceType | REPORT, CONTROL | FALSE | ENUMERATED (PRB UL, PRB DL, DRB, RRC) | Please refer to [6] clause 4.4.1, “resourceType” attribute. This IE should be included in RIC Services for enabling association with the correct instance of the O-RRMPolicyRatio RAN configuration structure. | +| rRMPolicyMemberList | REPORT, CONTROL | TRUE | 9.3.17 | Please refer to [6] clause 4.4.1, “rRMPolicyMemberList” attribute. This IE should be included in RIC Services for enabling association with the correct instance of the O-RRMPolicyRatio RAN configuration structure. | +| rRMPolicyMaxRatio | REPORT, CONTROL | TRUE | INTEGER (0..100) | Please refer to [6] clause 4.4.1, “rRMPolicyMaxRatio” attribute | +| rRMPolicyMinRatio | REPORT, CONTROL | TRUE | INTEGER (0..100) | Please refer to [6] clause 4.4.1, “rRMPolicyMinRatio” attribute | +| rRMPolicyDedicatedRatio | REPORT, CONTROL | TRUE | INTEGER (0..100) | Please refer to [6] clause 4.4.1, “rRMPolicyDedicatedRatio” attribute | + +### 8.8.2 Attribute Definitions for Cell-Level RAN Configuration Structures + +#### 8.8.2.1 O-NRCellCU + +| IE/Group Name | Supported Services | Is writable | IE type and reference | Semantics description | +|---------------|--------------------|-------------|-----------------------|---------------------------------------------------------------------| +| cellLocalId | REPORT, CONTROL | FALSE | INTEGER | Please refer to [6] clause 4.4.1, "cellLocalId" attribute | +| pLMNInfoList | REPORT, CONTROL | FALSE | 9.3.15 | Please refer to [6] clause 4.4.1, "NRCellCU.pLMNInfoList" attribute | + +#### 8.8.2.2 O-NRCellDU + +| IE/Group Name | Supported Services | Is writable | IE type and reference | Semantics description | +|----------------------|--------------------|-------------|----------------------------------------------|---------------------------------------------------------------------| +| cellLocalId | REPORT | FALSE | INTEGER | Please refer to [6] clause 4.4.1, "cellLocalId" attribute | +| operationalState | REPORT | FALSE | ENUMERATED (ENABLED, DISABLED) | Please refer to [6] clause 4.4.1, "operationalState" attribute | +| administrativeState | REPORT | FALSE | ENUMERATED (LOCKED, SHUTTING DOWN, UNLOCKED) | Please refer to [6] clause 4.4.1, "administrativeState" attribute | +| cellState | REPORT | FALSE | ENUMERATED (IDLE, INACTIVE, ACTIVE) | Please refer to [6] clause 4.4.1, "cellState" attribute | +| pLMNInfoList | REPORT | FALSE | 9.3.15 | Please refer to [6] clause 4.4.1, "NRCellDU.pLMNInfoList" attribute | +| nRPCI | REPORT | FALSE | INTEGER (0..503) | Please refer to [6] clause 4.4.1, "nRPCI" attribute | +| nRTAC | REPORT | FALSE | INTEGER (0..16777215) | Please refer to [6] clause 4.4.1, "nRTAC" attribute | +| arfcnDL | REPORT | FALSE | INTEGER | Please refer to [6] clause 4.4.1, "arfcnDL" attribute | +| arfcnUL | REPORT | FALSE | INTEGER | Please refer to [6] clause 4.4.1, "arfcnUL" attribute | +| arfcnSUL | REPORT | FALSE | INTEGER | Please refer to [6] clause 4.4.1, "arfcnSUL" attribute | +| bSChannelBwDL | REPORT | FALSE | INTEGER | Please refer to [6] clause 4.4.1, "bSChannelBwDL" attribute | +| ssbFrequency | REPORT | FALSE | INTEGER (0..3279165) | Please refer to [6] clause 4.4.1, "ssbFrequency" attribute | +| ssbPeriodicity | REPORT | FALSE | ENUMERATED (5, 10, 20, 40, 80, 160) | Please refer to [6] clause 4.4.1, "ssbPeriodicity" attribute | +| ssbSubCarrierSpacing | REPORT | FALSE | ENUMERATED (15, 30, 120, 240) | Please refer to [6] clause 4.4.1, "ssbSubCarrierSpacing" attribute | +| ssbOffset | REPORT | FALSE | INTEGER (0..159) | Please refer to [6] clause 4.4.1, "ssbOffset" attribute | + +| | | | | | +|----------------|-----------------|-------|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------| +| ssbDuration | REPORT | FALSE | ENUMERATED (1, 2, 3, 4, 5) | Please refer to [6] clause 4.4.1, “ssbDuration” attribute | +| bSChannelBwUL | REPORT | FALSE | INTEGER | Please refer to [6] clause 4.4.1, “bSChannelBwUL” attribute | +| bSChannelBwSUL | REPORT | FALSE | INTEGER | Please refer to [6] clause 4.4.1, “bSChannelBwSUL” attribute | +| bWPList | REPORT | FALSE | 9.3.18 | This attribute contains the list of O-BWPs. See clause 8.8.2.3 for O-BWP definition. | +| partitionList | REPORT, CONTROL | TRUE | 9.3.21 | This O-RAN specific attribute contains the list of frequency partitions for interference control for RAN Slice SLA Assurance use case. | + +#### 8.8.2.3 O-BWP + +| IE/Group Name | Presence | Is writable | IE type and reference | Semantics description | +|-------------------|-----------------|-------------|-------------------------------|-----------------------------------------------------------------| +| bwpContext | REPORT, CONTROL | TRUE | ENUMERATED (DL, UL, SUL) | Please refer to [6] clause 4.4.1, “bwpContext” attribute | +| isInitialBwp | REPORT, CONTROL | TRUE | ENUMERATED (INITIAL, OTHER) | Please refer to [6] clause 4.4.1, “isInitialBwp” attribute | +| subCarrierSpacing | REPORT, CONTROL | TRUE | ENUMERATED (15, 30, 60, 120) | Please refer to [6] clause 4.4.1, “subCarrierSpacing” attribute | +| cyclicPrefix | REPORT, CONTROL | TRUE | ENUMERATED (NORMAL, EXTENDED) | Please refer to [6] clause 4.4.1, “cyclicPrefix” attribute | +| startRB | REPORT, CONTROL | TRUE | INTEGER | Please refer to [6] clause 4.4.1, “startRB” attribute | +| numberOfRBs | REPORT, CONTROL | TRUE | INTEGER | Please refer to [6] clause 4.4.1, “numberOfRBs” attribute | + +#### 8.8.2.4 O-RRMPolicyRatio + +Please refer to clause 8.8.1.4 for O-RRMPolicyRatio attribute definitions. + +#### 8.8.2.5 O-CESManagementFunction + +This IOC embodies the management capabilities for Energy Saving (ES) functions. Its purpose is to facilitate energy-saving for individual cell. + +| IE/Group Name | Supported Services | Is writable | IE type and reference | Semantics description | +|---------------------|--------------------|-------------|----------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| +| cesSwitch | REPORT | FALSE | ENUMERATED (TRUE, FALSE) | Please refer to [6] clause 4.4.1, "cesSwitch" attribute. This attribute determines whether the energy-saving function is enabled or disabled for cell. | +| energySavingState | REPORT | FALSE | ENUMERATED (isNotEnergySaving, isEnergySaving) | Please refer to [6] clause 4.4.1, "energySavingState" attribute. Specifies the status regarding the energy-saving in the cell. | +| energySavingControl | REPORT, CONTROL | TRUE | ENUMERATED (toBeEnergySaving, toBeNotEnergySaving) | Please refer to [6] clause 4.4.1, "energySavingControl". This attribute allows the Near-RT RIC to initiate energy-saving activation or deactivation. | + +#### 8.8.2.6 O-NESPolicy + +This IOC embodies attribute(s) that are needed to provide the NES policy(s) to O-DU for TRX Control (RF Channel Reconfiguration) and Advanced Sleep Mode optimization, see clause 16.3.4 of [11]. + +NOTE: After receiving the TRX or ASM configuration, the E2 node shall try to achieve the configured behaviour. However, it is up to the E2 node to decide when and whether the configuration can be applied. + +| IE/Group Name | Supported Services | Is writable | IE type and reference | Semantics description | +|-----------------|--------------------|-------------|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| policyType | REPORT, CONTROL | FALSE | 9.3.22 | Policy type to indicate whether the policy is for ASM or TRX Control. | +| antennaMaskName | REPORT, CONTROL | TRUE | 9.3.23 | "antennaMaskName" corresponds to the selected "mask-name" in the list, "supported-trx-control-masks", provided by O-RU, see clause 20.3.1.2 of [10]. | +| antennaMask | REPORT, CONTROL | TRUE | 9.3.24 | Antenna mask contains an octet string mask value indicating which antenna element to be switched off/on, see clause 16.2 of [9]. It is used if supported antenna mask list is not reported by the O-RU, which means the O-RU supports any mask value (see 20.3.1.2 of [10]). | +| sleepMode | REPORT, CONTROL | TRUE | 9.3.25 | In case "policyType" is ASM, "sleepMode" corresponds to the selected "sleep-mode-type" in the list of the supported sleep modes provided by the O-RU for ASM, see clause 20.4.1 of [10].<br><br>In case "policyType" is TRX_CONTROL, "sleepMode" corresponds to the selected "sleep-mode-type" in the list of the supported sleep modes provided by the O-RU for TRX Control, see clause 20.3.1 of [10]. | +| dataDir | REPORT, CONTROL | FALSE | 9.3.26 | Applied data direction, DL or UL, of the configuration. | + +| | | | | | +|-------------------|--------------------|------|--------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| symbolMask | REPORT,<br>CONTROL | TRUE | 9.3.27 | Indicates the OFDM symbols in a slot for which the sleep mode configuration above (antennaMaskName, antennaMask, sleepMode, dataDir) to be applied.<br><br>If absent, all symbols are applied | +| slotMask | REPORT,<br>CONTROL | TRUE | 9.3.28 | “slotMask” contains an octet string mask value indicating the slot numbers in a frame (repeated sleep pattern every frame) for which the sleep mode configuration (antennaMaskName, antennaMask, sleepMode, dataDir, symbolMask) can be applied except slots for common channels (e.g. paging, RA, SSB, SIB1, SIB2, etc.).<br><br>If absent, all slots except slots for common channels (e.g. paging, RA, SSB, SIB1, SIB2, etc.) are applied. | +| validDuration | REPORT,<br>CONTROL | TRUE | 9.3.29 | Indicate the time duration in unit of 10ms for which the sleep mode configuration above (antennaMaskName, antennaMask, sleepMode, symbolMask, slotMask) to be valid.<br><br>If absent, the sleep mode configuration is expected to be applicable until cancelled (the policy is removed). | +| esObjective | REPORT,<br>CONTROL | TRUE | 9.3.30 | Indicate the expected energy saving target. | +| perfObjectiveList | REPORT,<br>CONTROL | TRUE | 9.3.36 | A list of performance objectives where each performance objective indicates the expected QoS performance target to be achieved for a service type in one or more network slice(s) identified by the corresponding 5QI value and optional slice identifier(s), and on the data direction indicated by dataDir.<br><br>It is configured along with “esObjective” to tune the system between maximum performance and maximum energy saving, e.g. reducing eMBB service throughput in order to save more energy. | + +#### 8.8.2.7 O-CellDTXDRXConfig + +The O-CellDTXDRXConfig IE embodies the cell DTX/DRX configuration of a serving cell, and it is defined as follows. + +NOTE 1: Only one O-CellDTXDRXConfig instance can be present for a cell. + +NOTE 2: If the cell DTX/DRX configuration is activated and if there is any overlap between the configured cell DTX/DRX active period (active cell transmission/reception) and the sleep duration specified in the O-NES Policy using the symbolMask and slotMask parameters for the ASM policy type, E2 Node shall not implement the O-NES ASM policy during the overlap. If the cell DTX/DRX configuration is activated and there is any overlap between the configured cell DTX/DRX non-active period (inactive cell transmission/reception) and the sleep duration in O-NES ASM policy, E2 Node shall apply the cell DTX/DRX non-active period during the overlapping slots or symbols. In addition, E2 node may apply the sleep duration based on ASM configuration in O-NES policy during the overlapping slots or symbols. + +| IE/Group Name | Supported Services | Is writable | IE type and reference | Semantics description | +|------------------|--------------------|-------------|-------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| onDurationTimer | REPORT, CONTROL | TRUE | 9.3.31 | Refer to 3GPP TS 38.331 [13], clause 6.3.2, "cellDTXDRX-onDurationTimer" description. | +| cycleStartOffset | REPORT, CONTROL | TRUE | 9.3.32 | Refer to 3GPP TS 38.331 [13], clause 6.3.2, "cellDTXDRX-CycleStartOffset" description. | +| slotOffset | REPORT, CONTROL | TRUE | INTEGER (0..31) | Indicates the slot-level offset. Value in multiple of 1/32 ms. Value 1 corresponds to 1/32 ms, value 2 corresponds to 2/32 ms, and so on Refer to 3GPP TS 38.331 [13], clause 6.3.2, "cellDTXDRX-SlotOffset" description. | +| configType | REPORT, CONTROL | TRUE | ENUMERATED (DTX, DRX, DTXDRX) | Indicates whether the configuration is for cell DTX only, cell DRX only, or joint cell DTX/DRX configuration. Refer to 3GPP TS 38.331 [13], clause 6.3.2, "cellDTXDRXconfigType" description. | +| activationStatus | REPORT, CONTROL | TRUE | ENUMERATED (ACTIVATED, DEACTIVATED) | Initial activation status of cell DTX/DRX. Refer to 3GPP TS 38.331 [13], clause 6.3.2, "cellDTXDRXactivationStatus" description. | +| l1Activation | REPORT, CONTROL | TRUE | ENUMERATED (ENABLED, DISABLED) | Indicates whether the cell enables L1 signaling (DCI 2_9) for dynamic activation/deactivation of cell DTX/DRX configuration. Refer to 3GPP TS 38.331, clause 6.3.2 [13], "cellDTXDRX-L1activation" description. | + +#### 8.8.2.8 O-RUInfo + +| IE/Group Name | Supported Services | Is writable | IE type and reference | Semantics description | +|---------------------------|--------------------|-------------|-----------------------|------------------------------------------------------------------------------------------------------------------------------------| +| oruUserPlaneConfiguration | REPORT | FALSE | 9.3.33 | The oruUserPlaneConfiguration is a list of user plane configurations supported by the O-RU from the o-ran-uplane-conf.yang module. | +| oruCapabilities | REPORT | FALSE | 9.3.37 | The oruCapabilities contains O-RU capability related information supported by the O-RU from the o-ran-module-cap.yang module. | + +# 9 Elements for E2SM Service Model + +## 9.1 General + +Void + +## 9.2 Message Functional Definition and Content + +### 9.2.1 Messages for RIC Functional procedures + +#### 9.2.1.1 RIC Event Trigger Definition IE + +This information element is part of the RIC SUBSCRIPTION REQUEST message sent by the Near-RT RIC to an E2 Node and is required for event triggers used to initiate REPORT, INSERT and POLICY actions. + +Direction: NEAR-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------------|----------|-------|-----------------------|--------------------------------------------------------------------------------| +| <b>CHOICE Event Trigger Definition Format</b> | | | | | +| >E2SM-CCC Event Trigger Definition Format 1 | M | | 9.2.1.1.1 | Triggered upon subscription and when a node-level configuration change occurs. | +| >E2SM-CCC Event Trigger Definition Format 2 | M | | 9.2.1.1.2 | Triggered upon subscription and when a cell-level configuration change occurs. | +| >E2SM-CCC Event Trigger Definition Format 3 | M | | 9.2.1.1.3 | Used for periodic event triggering | + +##### 9.2.1.1.1 E2SM-CCC Event Trigger Definition Format 1: Node-Level Configuration Change + +This event trigger definition format is used to configure E2 Nodes to trigger events when a node-level configuration change occurs. The list of RAN Configuration Structures defined in clause 8.3.1 shall be included. Any changes (addition, modification, deletion) regarding the listed RAN Configuration Structures shall trigger an event within the E2 Node. Optionally specific attributes for a certain RAN Configuration Structure can be configured to trigger an event if specified with *Attribute Name* IE within *List of Attributes* for that RAN Configuration Structure. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|----------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Node-level Configuration Structures | | 1..<maxnoof NodeLevelConfigStructures> | | | +| >RAN Configuration Structure Name | M | | 9.3.7 | Specifies the name of the node-level RAN configuration structure that the event will be triggered when a configuration change (addition, modification, deletion) occurs. Valid RAN Configuration Structures for this event trigger are defined in 8.3.1. | +| >List of Attributes | | 0..<maxnoof AttributesToReport> | | Optionally specifies the list of attributes within the RAN Configuration Structure that will only cause an event trigger upon change. Absence of this IE indicates that all attributes of the specified RAN Configuration Structure will trigger the event upon change. | +| >>Attribute Name | M | | 9.3.8 | Specifies the name of the attribute under the RAN Configuration Structure that will trigger the event upon change. Valid attributes for each node-level RAN Configuration Structure are defined in 8.8.1. | + +| Range bound | Explanation | +|----------------------------------|---------------------------------------------------------------------------------------------------------------------------| +| maxnoofNodeLevelConfigStructures | Maximum number of E2 Node level configuration structures that can be listed for the event triggering. The value is <256>. | +| maxnoofAttributesToReport | Maximum no. of attributes supported by Event Trigger Definition Format 1. The value is 65535. | + +##### 9.2.1.1.2 E2SM-CCC Event Trigger Definition Format 2: Cell-Level Configuration Change + +This event trigger definition format is used to configure E2 Nodes to trigger events when a cell-level configuration change occurs. The list of RAN Configuration Structures defined in clause 8.3.2 shall be included. Any changes (addition, modification, deletion) regarding the listed RAN Configuration Structures shall trigger an event for any cell within the E2 Node. The list of RAN Configuration Structures for event triggering can optionally be configured to be triggered for a specific cell, if indicated by the *Global Cell Id* IE. In addition, optionally specific attributes for a certain RAN Configuration Structure can be configured to trigger an event if specified with *Attribute Name* IE within *List of Attributes* for that RAN Configuration Structure. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|----------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Cell-level Configuration Structures | | 1..<maxnoof Cells> | | | +| > Cell Global Id | O | | 9.3.6 | Specifies the global cell id of the cell the event will be triggered for. Absence of this IE indicates that a configuration change (addition, modification, deletion) in any cell regarding the listed RAN Configuration Structures shall trigger an event. | +| >List of RAN Configuration Structures | | 1..<maxnoof CellLevelConfigStructures> | | | +| >>RAN Configuration Structure Name | M | | 9.3.7 | Specifies the name of the cell-level RAN configuration structure that the event will be triggered when a configuration change (addition, modification, deletion) occurs. Valid RAN Configuration Structures for this event trigger are defined in 8.3.2. | +| >>List of Attributes | | 0..<maxnoof AttributesTo Report> | | Optionally specifies the list of attributes within the RAN Configuration Structure that will only cause an event trigger upon change. Absence of this IE indicates that all attributes of the specified RAN Configuration Structure will trigger the event upon change. | +| >>>Attribute Name | M | | 9.3.8 | Specifies the name of the attribute under the RAN Configuration Structure that will trigger the event upon change. Valid attributes for each cell-level RAN Configuration Structure are defined in 8.8.2. | + +| Range bound | Explanation | +|----------------------------------|----------------------------------------------------------------------------------------------------------------------------| +| maxnoofCells | Maximum number of cells that can be listed for the event triggering. The value is <1024>. | +| maxnoofCellLevelConfigStructures | Maximum number of E2 Node level configuration structures that can be listed for the event triggering. The value is <1024>. | +| maxnoofAttributesToReport | Maximum no. of attributes supported by Event Trigger Definition Format 2. The value is 65535. | + +##### 9.2.1.1.3 E2SM-CCC Event Trigger Definition Format 3: Periodic Event Trigger + +This event trigger definition format is used to configure E2 Nodes to trigger events in a certain period. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|--------------------------|-----------------------------------------------------------------------| +| Period | M | | INTEGER (10..4294967295) | Used to indicate the event triggering period in unit of 1 millisecond | + +#### 9.2.1.2 RIC ACTION DEFINITION IE + +This information element is part of the RIC SUBSCRIPTION REQUEST message sent by the Near-RT RIC to an E2 Node. In this service model, this information element provides additional information for the nominated Action (Report). + +Direction: NEAR-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|----------|-------|-----------------------|----------------------------------------------------------------------| +| RIC Style Type | M | | 9.3.3 | | +| <b>CHOICE</b> Action Definition Format | | | | | +| >E2SM-CCC Action Definition Format 1 | M | | 9.2.1.2.1 | Used by REPORT service to report node-level configuration structures | +| >E2SM-CCC Action Definition Format 2 | M | | 9.2.1.2.2 | Used by REPORT service to report cell-level configuration structures | + +##### 9.2.1.2.1 E2SM-CCC Action Definition Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------------|----------|--------------------------------------------------|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Node-level RAN Configuration Structures | M | 1.. <i><maxnoofConfigurationsToReport></i> | | | +| >Report Type | M | | 9.3.9 | Indicates whether:<br>- the values for the configuration structures listed shall be reported regardless there has been a change or not<br>- the values for the configuration structures listed shall be reported only if its value has been changed (modification, addition, deletion) | +| >RAN Configuration Structure Name | M | | 9.3.7 | Specifies the name of the node-level RAN configuration structure that shall be reported. Valid RAN Configuration Structures for this action definition are defined in 8.4.1. | +| >List of Attributes | | 0.. <i><maxnoofAttributesToReport></i> | | | +| >>Attribute Name | M | | 9.3.8 | Specifies the name of the required attribute. The value of the attribute shall be reported. Valid attributes for this action definition are defined in 8.8.1. | + +| Range bound | Explanation | +|-------------------------------|------------------------------------------------------------------------------------------| +| maxnoofConfigurationsToReport | Maximum no. of configurations supported by Action Definition Format 1. The value is 256. | +| maxnoofAttributesToReport | Maximum no. of attributes supported by Action Definition Format 1. The value is 65535. | + +##### 9.2.1.2.2 E2SM-CCC Action Definition Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------------|----------|-------------------------------------------------|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Cell Configurations To Be Reported | | <i>1..<maxnoofCellsToReport></i> | | | +| > Cell Global Id | O | | 9.3.6 | Indicates the global cell id of the cell that cell-level configuration structure list applies for. Absence of this IE indicates that listed cell-level configuration structures apply for all cells within the E2 Node. | +| >List of Cell-level RAN Configuration Structures | | <i>1..<maxnoofConfigurationsToReport></i> | | | +| >>Report Type | M | | 9.3.9 | Indicates whether:<br>- the values for the configuration structures listed shall be reported regardless there has been a change or not<br>- the values for the configuration structures listed shall be reported only if its value has been changed (modification, addition, deletion) | +| >>RAN Configuration Structure Name | M | | 9.3.7 | Specifies the name of the cell-level RAN configuration structure that shall be reported. Valid RAN Configuration Structures for this action definition are defined in 8.4.2. | +| >>List of Attributes | | <i>0..<maxnoofAttributesToReport></i> | | | +| >>>Attribute Name | M | | 9.3.8 | Specifies the name of the required attribute. The value of the attribute shall be reported. Valid attributes for this action definition are defined in 8.8.2. | + +| Range bound | Explanation | +|-------------------------------|-------------------------------------------------------------------------------------------| +| maxnoofCellsToReport | Maximum no. of cells supported by Action Definition Format 2. The value is 1024. | +| maxnoofConfigurationsToReport | Maximum no. of configurations supported by Action Definition Format 2. The value is 1024. | +| maxnoofAttributesToReport | Maximum no. of attributes supported by Action Definition Format 2. The value is 65535. | + +#### 9.2.1.3 RIC INDICATION HEADER IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to the Near-RT RIC and is required for REPORT action. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Indication Header Format</i> | | | | | +| >E2SM-CCC Indication Header Format 1 | M | | | | + +##### 9.2.1.3.1 E2SM-CCC Indication Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------|----------|-------|-------------------------------------------------------|-----------------------------------------| +| Indication Reason | M | | ENUMERATED (Upon Subscription, Upon Change, Periodic) | Provides the cause of the event trigger | +| Event Time | M | | 9.3.10 | Provides the time of the event trigger. | + +#### 9.2.1.4 RIC INDICATION MESSAGE IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to the Near-RT RIC and is required for REPORT action. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Indication Message Format</i> | | | | | +| >E2SM-CCC Indication Message Format 1 | M | | | | +| >E2SM-CCC Indication Message Format 2 | M | | | | + +##### 9.2.1.4.1 E2SM-CCC Indication Message Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------|----------|----------------------------------------------------|-----------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Configuration Structures Reported | | 1.. <i><maxnoof Configuration sReported></i> | | Indicates the configuration structures that are reported within the message. | +| >Change Type | M | | ENUMERATED (None, Modification, Addition, Deletion) | <p>None - no change occurred in reported RAN configuration structure attributes – e.g., due to periodic reporting or initial subscription. Values of attributes shall be reported through “Values of Attributes”.</p> <p>Modification - a modification of value occurred in at least one attribute of the RAN configuration structure. New values shall be reported through “Values of Attributes” and old attribute values shall be reported through “Old Values of Attributes”.</p> <p>Addition - Notification of addition of a new RAN configuration structure. Values of its attributes shall be reported through “Values of Attributes”.</p> <p>Deletion - Notification of deletion of a RAN configuration structure. Deleted attribute values shall be reported through “Values of Attributes”.</p> | +| >RAN Configuration Structure Name | M | | 9.3.7 | Indicates the RAN Configuration Structure name. | +| >Values of Attributes | M | | OCTET STRING | Provides the attribute values for the respective RAN Configuration Structure defined in clause 8.4.1. | +| >Old Values of Attributes | O | | OCTET STRING | Provides the old values of the attributes for the respective RAN Configuration Structure defined in clause 8.4.1 and shall be included if “Change Type” equals to “Modification”. | + +| Range bound | Explanation | +|-------------------------------|---------------------------------------------------------------------------------------------| +| maxnoofConfigurationsReported | Maximum no. of configurations supported by Indication Message Format 1. The value is 65535. | + +##### 9.2.1.4.2 E2SM-CCC Indication Message Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------|----------|------------------------------------|-----------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Cells Reported | | 1..<maxnoofCellsReported> | | Indicates the cells and respective configuration structures that are reported within the message. | +| >Cell Global Id | M | | 9.3.6 | Indicates the cell the event was triggered for. | +| >List of Configuration Structures Reported | | 1..<maxnoofConfigurationsReported> | | Indicates the configuration structures that are reported within the message that belong to the cell. | +| >>Change Type | M | | ENUMERATED (None, Modification, Addition, Deletion) | <p>None - no change occurred in reported RAN configuration structure attributes – e.g., due to periodic reporting or initial subscription. Values of attributes shall be reported through “Values of Attributes”.</p> <p>Modification - a modification of value occurred in at least one attribute of the RAN configuration structure. New values shall be reported through “Values of Attributes” and old attribute values shall be reported through “Old Values of Attributes”.</p> <p>Addition - Notification of addition of a new RAN configuration structure. Values of its attributes shall be reported through “Values of Attributes”.</p> <p>Deletion - Notification of deletion of a RAN configuration structure. Deleted attribute values shall be reported through “Values of Attributes”.</p> | +| >>RAN Configuration Structure Name | M | | 9.3.7 | Indicates the RAN Configuration Structure name. | +| >>Values of Attributes | M | | OCTET STRING | Provides the attribute values for the respective RAN Configuration Structure defined in clause 8.4.2. | +| >>Old Values of Attributes | O | | OCTET STRING | Provides the old values of the attributes for the respective RAN Configuration Structure defined in clause 8.4.2 and shall be included if “Change Type” equals to “Modification”. | + +| Range bound | Explanation | +|-------------------------------|---------------------------------------------------------------------------------------------| +| maxnoofCellsReported | Maximum no. of cells supported by Indication Message Format 2. The value is 65535. | +| maxnoofConfigurationsReported | Maximum no. of configurations supported by Indication Message Format 2. The value is 65535. | + +#### 9.2.1.6 RIC CONTROL HEADER IE + +This information element is part of the RIC CONTROL message sent by the Near-RT RIC to an E2 Node and is required for RIC Control Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Control Header Format</i> | | | | | +| >E2SM-CCC Control Header Format 1 | M | | 9.2.1.6.1 | | + +##### 9.2.1.6.1 E2SM-CCC Control Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------|-----------------------| +| RIC Style Type | M | | 9.3.3 | Refer to clause 7.6.1 | + +#### 9.2.1.7 RIC CONTROL MESSAGE IE + +This information element is part of the RIC CONTROL message sent by the Near-RT RIC to an E2 Node and is required for RIC Control Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Control Message Format</i> | | | | | +| >E2SM-CCC Control Message Format 1 | M | | 9.2.1.7.1 | | +| >E2SM-CCC Control Message Format 2 | M | | 9.2.1.7.2 | | + +##### 9.2.1.7.1 E2SM-CCC Control Message Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|------------------------------------------|-----------------------|-----------------------------------------------------------------------------------------------------------| +| List of Configuration Structures | | 1.. <i><maxnoofConfigurations></i> | | Indicates the configuration structures that are controlled within the message. | +| >RAN Configuration Structure Name | M | | 9.3.7 | Indicates the RAN Configuration Structure name. | +| >Old Values of Attributes | M | | OCTET STRING | Provides the old attribute values for the respective RAN Configuration Structure defined in clause 8.6.1. | +| >New Values of Attributes | M | | OCTET STRING | Provides the new attribute values for the respective RAN Configuration Structure defined in clause 8.6.1. | + +| Range bound | Explanation | +|-----------------------|------------------------------------------------------------------------------------------| +| maxnoofConfigurations | Maximum no. of configurations supported by Control Message Format 1. The value is 65535. | + +##### 9.2.1.7.2 E2SM-CCC Control Message Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------|----------|------------------------------------------|-----------------------|-----------------------------------------------------------------------------------------------------------| +| List of Cells | | 1.. <i><maxnoofCells></i> | | | +| >Cell Global Id | M | | 9.3.6 | Indicates the target cell for control. | +| >List of Configuration Structures | | 1.. <i><maxnoofConfigurations></i> | | | +| >>RAN Configuration Structure Name | M | | 9.3.7 | Indicates the RAN Configuration Structure name. | +| >>Old Values of Attributes | M | | OCTET STRING | Provides the old attribute values for the respective RAN Configuration Structure defined in clause 8.6.2. | +| >>New Values of Attributes | M | | OCTET STRING | Provides the new attribute values for the respective RAN Configuration Structure defined in clause 8.6.2. | + +| Range bound | Explanation | +|-----------------------|------------------------------------------------------------------------------------------| +| maxnoofCells | Maximum no. of cells supported by Control Message Format 2. The value is 65535. | +| maxnoofConfigurations | Maximum no. of configurations supported by Control Message Format 2. The value is 65535. | + +#### 9.2.1.8 RIC CONTROL OUTCOME IE + +This information element is part of the RIC CONTROL ACKNOWLEDGEMENT and RIC CONTROL FAILURE messages and is sent by the E2 Node to the Near-RT RIC and is required for RIC Control Procedure. + +Direction: E2 Node → Near-RT RIC + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Control Outcome Format</i> | | | | | +| >E2SM-CCC Control Outcome Format 1 | M | | 9.2.1.8.1 | | +| >E2SM-CCC Control Outcome Format 2 | M | | 9.2.1.8.2 | | + +##### 9.2.1.8.1 E2SM-CCC Control Outcome Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------|----------|------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Received Timestamp | O | | OCTET STRING | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in clause 6 of IETF RFC 5905 [5] containing both seconds and fraction parts. | +| RAN Configuration Structures Accepted List | | 0.. <i>maxnoofConfigurations</i> > | | Indicates the list of configuration structure changes that are accepted by the E2 Node. | +| >RAN Configuration Structure Name | M | | 9.3.7 | Indicates the RAN Configuration Structure name. | +| >Old Values of Attributes | M | | OCTET STRING | Provides the old attribute values for the respective RAN Configuration Structure defined in clause 8.6.1. | +| >Current Values of Attributes | M | | OCTET STRING | Provides the current attribute values for the respective RAN Configuration Structure defined in clause 8.6.1. | +| >Applied Timestamp | O | | OCTET STRING | Time RAN configuration change was applied by the RAN Function.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in clause 6 of IETF RFC 5905 [5] containing both seconds and fraction parts. | +| RAN Configuration Structures Failed List | | 0.. <i>maxnoofConfigurations</i> > | | Indicates the list of configuration structure changes that are failed by the E2 Node. | +| >RAN Configuration Structure Name | M | | 9.3.7 | Indicates the RAN Configuration Structure name. | +| >Old Values of Attributes | M | | OCTET STRING | Provides the old attribute values for the respective RAN Configuration Structure defined in clause 8.6.1. | +| >Requested Values of Attributes | M | | OCTET STRING | Provides the requested attribute values for the respective RAN Configuration Structure defined in clause 8.6.1. | +| >Cause | M | | 9.3.11 | Provides the cause of the failure | + +| Range bound | Explanation | +|-----------------------|------------------------------------------------------------------------------------------| +| maxnoofConfigurations | Maximum no. of configurations supported by Control Outcome Format 1. The value is 65535. | + +##### 9.2.1.8.2 E2SM-CCC Control Outcome Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|----------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Received Timestamp | O | | OCTET STRING | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in clause 6 of IETF RFC 5905 [5] containing both seconds and fraction parts. | +| List of Cells | | 1..<maxnoofCells> | | | +| >Cell Global Id | M | | 9.3.6 | Indicates the target cell for control. | +| >RAN Configuration Structures Accepted List | | 0..<maxnoofConfigurations> | | Indicates the list of configuration structure changes that are accepted by the Cell. | +| >>RAN Configuration Structure Name | M | | 9.3.7 | Indicates the RAN Configuration Structure name. | +| >>Old Values of Attributes | M | | OCTET STRING | Provides the old attribute values for the respective RAN Configuration Structure defined in clause 8.6.2. | +| >>Current Values of Attributes | M | | OCTET STRING | Provides the current attribute values for the respective RAN Configuration Structure defined in clause 8.6.2. | +| >>Applied Timestamp | O | | OCTET STRING | Time RAN configuration change was applied by the RAN Function.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in clause 6 of IETF RFC 5905 [5] containing both seconds and fraction parts. | +| >RAN Configuration Structures Failed List | | 0..<maxnoofConfigurations> | | Indicates the list of configuration structure changes that are failed by the Cell. | +| >>RAN Configuration Structure Name | M | | 9.3.7 | Indicates the RAN Configuration Structure name. | +| >>Old Values of Attributes | M | | OCTET STRING | Provides the old attribute values for the respective RAN Configuration Structure defined in clause 8.6.2. | +| >>Requested Values of Attributes | M | | OCTET STRING | Provides the requested attribute values for the respective RAN Configuration Structure defined in clause 8.6.2. | +| >>Cause | M | | 9.3.11 | Provides the cause of the failure | + +| Range bound | Explanation | +|-----------------------|------------------------------------------------------------------------------------------| +| maxnoofCells | Maximum no. of cells supported by Control Outcome Format 2. The value is 65535. | +| maxnoofConfigurations | Maximum no. of configurations supported by Control Outcome Format 2. The value is 65535. | + +#### 9.2.1.9 RIC QUERY HEADER IE + +This information element is part of the RIC QUERY REQUEST message sent by the Near-RT RIC to an E2 Node and is required for RIC QUERY Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> Query Header Format | M | | | | +| >E2SM-CCC Query Header Format 1 | | | 9.2.1.9.1 | | + +##### 9.2.1.9.1 E2SM-CCC Query Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------|------------------------| +| RIC Style Type | M | | 9.3.3 | Refer to clause 7.7A.1 | + +#### 9.2.1.10 RIC QUERY DEFINITION IE + +This information element is part of the RIC QUERY REQUEST message sent by the Near-RT RIC to an E2 Node and is required for RIC Query Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> Query Definition Format | M | | | | +| >E2SM-CCC Query Definition Format 1 | | | 9.2.1.10.1 | | +| >E2SM-CCC Query Definition Format 2 | | | 9.2.1.10.2 | | + +##### 9.2.1.10.1 E2SM-CCC Query Definition Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------------|----------|------------------------------------|-----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Node-level RAN Configuration Structures | M | 1..<maxnoofConfigurationsToReport> | | | +| >RAN Configuration Structure Name | M | | 9.3.7 | Specifies the name of the node-level RAN configuration structure that shall be reported. Valid RAN Configuration Structures for this query definition are defined in 8.9.1 | +| >List of Attributes | | 0..<maxnoofAttributesToReport> | | | +| >>Attribute Name | M | | 9.3.8 | Specifies the name of the required attribute. The value of the attribute shall be reported. Valid attributes for each node-level RAN Configuration Structure are defined in 8.8.1. | + +| Range bound | Explanation | +|-------------------------------|-----------------------------------------------------------------------------------------| +| maxnoofConfigurationsToReport | Maximum no. of configurations supported by Query Definition Format 1. The value is 256. | +| maxnoofAttributesToReport | Maximum no. of attributes supported by Query Definition Format 1. The value is 65535. | + +##### 9.2.1.10.2 E2SM-CCC Query Definition Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------------|----------|-------------------------------------------------|-----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Cells To Be Queried | | <i>1..<maxnoofCellsToReport></i> | | | +| > Cell Global Id | O | | 9.3.6 | Indicates the global cell id of the cell that List of Cell-level Configuration Structures to Be Queried applies for. Absence of this IE indicates that listed cell-level RAN configuration structures apply for all cells within the E2 Node. | +| >List of Cell-level Configuration Structures | | <i>1..<maxnoofConfigurationsToReport></i> | | This IE is mandatory for Query Service Style2. | +| >>RAN Configuration Structure Name | M | | 9.3.7 | Specifies the name of the cell-level RAN configuration structure that shall be reported. Valid RAN Configuration Structures for this query definition are defined in 8.9.2. | +| >>List of Attributes | | <i>0..<maxnoofAttributesToReport></i> | | | +| >>>Attribute Name | M | | 9.3.8 | Specifies the name of the required attribute. Valid attributes for each cell-level RAN Configuration Structure are defined in 8.8.2. Valid attributes for this action definition are defined in 8.8.2. | + +| Range bound | Explanation | +|-------------------------------|------------------------------------------------------------------------------------------| +| maxnoofCellsToReport | Maximum no. of cells supported by Query Definition Format 2. The value is 1024. | +| maxnoofConfigurationsToReport | Maximum no. of configurations supported by Query Definition Format 2. The value is 1024. | +| maxnoofAttributesToReport | Maximum no. of attributes supported by Query Definition Format 2. The value is 65535. | + +#### 9.2.1.11 RIC QUERY OUTCOME IE + +This information element is part of the RIC QUERY RESPONSE message sent by the Near-RT RIC to an E2 Node and is required for RIC Query Procedure. + +Direction: E2 Node → Near-RT RIC + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> Query Outcome Format | M | | | | +| >E2SM-CCC Query Outcome Format 1 | | | 9.2.1.11.1 | | +| >E2SM-CCC Query Outcome Format 2 | | | 9.2.1.11.2 | | + +##### 9.2.1.11.1 E2SM-CCC Query Outcome Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------------------------|----------|-------------------------------------------------|-----------------------|------------------------------------------------------------------------------------------------------| +| List of Configuration Structures to Be Reported for Query | | <i>1..<maxnoofConfigurationsReported></i> | | Indicates the configuration structures that are reported within the message. | +| >RAN Configuration Structure Name | M | | 9.3.7 | Indicates the RAN Configuration Structure name. | +| >Values of Attributes | M | | OCTET STRING | Provides the attribute values for the respective RAN Configuration Structure defined in clause 8.9.1 | + +| Range bound | Explanation | +|-------------------------------|----------------------------------------------------------------------------------------| +| maxnoofConfigurationsReported | Maximum no. of configurations supported by Query Outcome Format 1. The value is 65535. | + +##### 9.2.1.11.2 E2SM-CCC Query Outcome Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------------------|----------|-------------------------------------------------|-----------------------|------------------------------------------------------------------------------------------------------| +| List of Cells to Be Reported for Query | | <i>1..<maxnoofCellsReported></i> | | Indicates the cells and respective configuration structures that are reported within the message. | +| >Cell Global Id | M | | 9.3.6 | Indicates the cell the event was triggered for. | +| >List of Configuration Structures to Be Reported for Query | | <i>1..<maxnoofConfigurationsReported></i> | | Indicates the configuration structures that are reported within the message that belong to the cell. | +| >>RAN Configuration Structure Name | M | | 9.3.7 | Indicates the RAN Configuration Structure name. | +| >>Values of Attributes | M | | OCTET STRING | Provides the attribute values for the respective RAN Configuration Structure defined in clause 8.9.2 | + +| Range bound | Explanation | +|-------------------------------|----------------------------------------------------------------------------------------| +| maxnoofCellsReported | Maximum no. of cells supported by Query Outcome Format 2. The value is 65535. | +| maxnoofConfigurationsReported | Maximum no. of configurations supported by Query Outcome Format 2. The value is 65535. | + +### 9.2.2 Messages for RIC Global Procedures + +#### 9.2.2.1 RAN Function Definition IE + +This information element is part of the E2 SETUP REQUEST, and RIC SERVICE UPDATE message sent by the E2 Node to the Near-RT RIC and is used to provide all required information for the Near-RT RIC to determine how a given E2 Node has been configured to support a given RAN Function specific E2SM. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------------------|----------|------------------------------------------|-----------------------|------------------------------------------------------------------------------------------------------------------| +| RAN Function Name | M | | 9.3.2 | | +| List of Supported Node-level RAN Configuration Structures | | <i>0..<maxno ofConfigurations></i> | | Indicates the list of Node-level RAN Configuration Structures that are supported by the E2 Node. | +| >RAN Configuration Structure Name | M | | 9.3.7 | | +| >List of Supported Attributes | | <i>0..<maxno ofAttributes></i> | | Provides the supported attributes for the respective RAN Configuration Structure defined in clause 8.6.1. | +| >>Attribute Name | M | | 9.3.8 | | +| >>Supported Services | M | | 9.2.2.2 | | +| List of Cells | | <i>0..<maxno ofCells></i> | | Provides the list of cells and supported RAN Configuration Structures and attributes corresponding to each cell. | +| >Cell Global Id | M | | 9.3.6 | | +| >List of Supported Cell-level RAN Configuration Structures | | <i>0..<maxno ofConfigurations></i> | | Indicates the list of Cell-level RAN Configuration Structures that are supported by the cell. | +| >>RAN Configuration Structure Name | M | | 9.3.7 | | +| >>List of Supported Attributes | | <i>0..<maxno ofAttributes></i> | | Provides the supported attributes for the respective RAN Configuration Structure defined in clause 8.6.2. | +| >>>Attribute Name | M | | 9.3.8 | | +| >>>Supported Services | M | | 9.2.2.2 | | + +| Range bound | Explanation | +|-----------------------|------------------------------------------------------------------------------------------------------| +| maxnoofCells | Maximum no. of cells supported by RAN Function Definition. The value is 1024. | +| maxnoofConfigurations | Maximum no. of RAN Configuration Structures supported by RAN Function Definition. The value is 1024. | +| maxnoofAttributes | Maximum no. of attributes supported by RAN Function Definition. The value is 65535. | + +#### 9.2.2.2 Supported Services + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------|----------|-------|-----------------------|-----------------------| +| Event Trigger | O | | 9.2.2.2.1 | | +| Report Service | O | | 9.2.2.2.2 | | +| Insert Service | O | | 9.2.2.2.3 | | +| Control Service | O | | 9.2.2.2.4 | | +| Policy Service | O | | 9.2.2.2.5 | | +| Query Service | O | | 9.2.2.2.6 | | + +##### 9.2.2.2.1 Event Trigger + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|----------|-------------------------------------|-----------------------|-----------------------| +| List of Supported Event Trigger Styles | | <i>1..<maxno ofRICstyles></i> | | | +| >Event Trigger Style Type | M | | 9.3.3 | | +| >Event Trigger Style Name | M | | 9.3.4 | | +| >Event Trigger Format Type | M | | 9.3.5 | | + +| Range bound | Explanation | +|-------------------------|---------------------------------------------------------------------| +| <i>maxnoofRICStyles</i> | Maximum no. of styles supported by RAN Function. The value is <63>. | + +##### 9.2.2.2.2 Report Service + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------|----------|--------------------------------------------------|-----------------------|-----------------------| +| List of Supported Report Styles | | <i>1..<br/><maxnoofRICStyles></i> | | | +| >Report Service Style Type | M | | 9.3.3 | | +| >Report Service Style Name | M | | 9.3.4 | | +| >List of Supported Event Trigger Styles | M | <i>1..<br/><maxnoofEventTriggerStyles></i> | | | +| >>Event Trigger Style Type | M | | 9.3.3 | | +| >Report Service Action Definition Format Type | M | | 9.3.5 | | +| >Report Service Indication Header Format Type | M | | 9.3.5 | | +| >Report Service Indication Message Format Type | M | | 9.3.5 | | + +| Range bound | Explanation | +|----------------------------------|---------------------------------------------------------------------| +| <i>maxnoofRICStyles</i> | Maximum no. of styles supported by RAN Function. The value is <63>. | +| <i>maxnoofEventTriggerStyles</i> | Maximum no. of styles supported by RAN Function. The value is <63>. | + +##### 9.2.2.2.3 Insert Service + +Void + +##### 9.2.2.2.4 Control Service + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------------|----------|---------------------------|-----------------------|-----------------------| +| List of Supported Control Styles | | 1..<br><maxnoofRICStyles> | | | +| >Control Service Style Type | M | | 9.3.3 | | +| >Control Service Style Name | M | | 9.3.4 | | +| >Control Service Header Format Type | M | | 9.3.5 | | +| >Control Service Message Format Type | M | | 9.3.5 | | +| >RIC Call Process ID Format Type | O | | 9.3.5 | | +| >Control Service Control Outcome Format Type | M | | 9.3.5 | | + +| Range bound | Explanation | +|------------------|---------------------------------------------------------------------| +| maxnoofRICStyles | Maximum no. of styles supported by RAN Function. The value is <63>. | + +##### 9.2.2.2.5 Policy Service + +Void + +##### 9.2.2.2.6 Query Service + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------|----------|---------------------------|-----------------------|--------------------------------------------------| +| List of Supported Query styles | | 1..<br><maxnoofRICStyles> | | | +| >Query Service Style Type | M | | 9.3.3 | | +| >Query Service Style Name | M | | 9.3.4 | | +| >Query Service Header Format Type | M | | 9.3.5 | Header type used by Query style | +| >Query Service Definition Format Type | M | | 9.3.5 | Query Definition format type used by Query style | +| >Query Service Outcome Format Type | M | | 9.3.5 | Query Outcome format type used by Query style | + +| Range bound | Explanation | +|------------------|---------------------------------------------------------------------| +| maxnoofRICstyles | Maximum no. of styles supported by RAN Function. The value is <63>. | + +## 9.3 Information Element definitions + +### 9.3.1 General + +Void. + +### 9.3.2 RAN Function Name + +This IE is defined in [4] clause 6.2.2.1. + +### 9.3.3 RIC Style Type + +This IE is defined in [4] clause 6.2.2.2. + +### 9.3.4 RIC Style Name + +This IE is defined in [4] clause 6.2.2.3. + +### 9.3.5 RIC Format Type + +This IE is defined in [4] clause 6.2.2.4. + +### 9.3.6 Cell Global ID + +This IE is defined in [4] clause 6.2.2.5. + +### 9.3.7 RAN Configuration Structure Name + +This IE defines the name of a given RAN Configuration Structure which are defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|-------|-----------------------|-----------------------| +| RAN Configuration Structure Name | M | | OCTET STRING | | + +### 9.3.8 Attribute Name + +This IE defines the name of a given attribute which are defined for each RAN Configuration Structure in clause 8.8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------|-----------------------| +| Attribute Name | M | | OCTET STRING | | + +### 9.3.9 Report Type + +This IE defines the reporting type of the RAN Configuration Structures. There are 2 types of reporting: + +- All: the RAN Configuration Structure shall be reported regardless there has been a change or not in its value +- Change: the RAN Configuration Structure shall be reported only if its value has been changed (e.g. modified, added, deleted) + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|--------------------------|-----------------------| +| Report Type | M | | ENUMERATED (All, Change) | | + +NOTE: When E2 Node sends the report for the event “upon subscription”, it shall report all the values for the listed RAN configuration structures regardless there has been a change or not. + +### 9.3.10 Event Time + +This IE defines the time of the event. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Event Time | M | | OCTET STRING | Carries UTC time encoded as the 64-bit timestamp format as defined in clause 6 of IETF RFC 5905 [5] containing both seconds and fraction parts. This parameter shall be encoded in hexadecimal format. | + +### 9.3.11 Cause + +This IE defines the cause of the failure for a control action within a RIC Control Outcome IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|--------------------------------------------------------------------------------------------------------|-----------------------| +| Cause | M | | ENUMERATED (Not supported, Not available, Incompatible state, JSON error, Semantic error, Unspecified) | | + +The meaning of the different cause values is presented in the following table. + +| Cause | Meaning | +|--------------------|---------------------------------------------------------------------------------------------| +| Not supported | Related capability is not supported within E2 Node | +| Not available | Resources are not available to perform the required action | +| Incompatible state | The received message is not compatible with current E2 Node state (e.g. Old value mismatch) | +| JSON error | The received message contains invalid JSON | +| Semantic error | The requested action included a semantic error | +| Unspecified | None of the above cause values applies | + +### 9.3.12 pLMNId + +This IE indicates the PLMN Identity and is defined in [4] clause 6.2.3.1. + +### 9.3.13 sNSSAI + +This IE indicates the S-NSSAI and is defined in [4] clause 6.2.3.12. + +### 9.3.14 pLMNInfo + +This IE is used to represent PLMN ID and S-NSSAI pair. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|------------------------------------------------------------------| +| pLMNId | M | | 9.3.12 | | +| sNSSAI | O | | 9.3.13 | This IE shall be present if network slicing feature is supported | + +### 9.3.15 pLMNInfoList + +This IE is used to represent list of pLMNInfo defined in 9.3.14. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-----------------------|-----------------------|-----------------------| +| pLMNInfoList | | 1..<maxnoof PLMNInfo> | | | +| >pLMNInfo | M | | 9.3.14 | | + +| Range bound | Explanation | +|-----------------|-------------------------------------------------------------------| +| maxnoofPLMNInfo | Maximum no. of PLMNInfo supported for an E2 Node. Value is 65536. | + +### 9.3.16 rRMPolicyMember + +This IE is used to represent RRM Policy member information. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|------------------------------------------------------------------| +| pLMNId | M | | 9.3.12 | | +| sNSSAI | O | | 9.3.13 | This IE shall be present if network slicing feature is supported | + +### 9.3.17 rRMPolicyMemberList + +This IE is used to represent list of rRMPolicyMember defined in 9.3.16. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|------------------------------|-----------------------|-----------------------| +| rRMPolicyMemberList | | 1..<maxnoof RRMPolicyMember> | | | +| >rRMPolicyMember | M | | 9.3.16 | | + +| Range bound | Explanation | +|------------------------|-----------------------------------------------------------| +| maxnoofRRMPolicyMember | Maximum no. of RRMPolicyMember supported. Value is 65536. | + +### 9.3.18 bWPList + +This IE is used to represent list of O-BWP defined in 8.8.2.3. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|------------------|-----------------------|-----------------------| +| bWPList | | 1..<maxnoof BWP> | | | +| >O-BWP | M | | 8.8.2.3 | | + +| Range bound | Explanation | +|-------------|-----------------------------------------------| +| maxnoofBWP | Maximum no. of O-BWP supported. Value is 256. | + +### 9.3.19 5QIList + +This IE is used to represent list of 5QIs included in an entry of partitionFlowList defined in 9.3.20. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|----------------------|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 5QIList | | 1..<maxnoof 5QIList> | | | +| >5QI | M | | INTEGER | As for standardized 5QI values, please refer to TS 23.501, 5.7.4 “Standardized 5QI to QoS characteristics mapping”, such as 70 for Mission Critical delay sensitive signalling, or 80 for Low Latency eMBB applications Augmented Reality. | + +| Range bound | Explanation | +|----------------|----------------------------------------------------------------| +| maxnoof5QIList | Maximum no. of 5QIList supported for an E2 Node. Value is 128. | + +### 9.3.20 partitionFlowList + +This IE is used to represent list of QoS flows included in an entry of partitionList defined in 9.3.21. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|---------------------------------|-----------------------|------------------------------------------------------------------------------------------------| +| partitionFlowList | | 1..<maxnoof PartitionFlow List> | | | +| >partitionFlow Item | M | | | | +| >>sNSSAI | M | | 9.3.13 | Pair of pLMNID and sNSSAI is used to uniquely identify an applicable slice. | +| >>pLMNID | M | | 9.3.12 | Pair of pLMNID and sNSSAI is used to uniquely identify an applicable slice. | +| >>5QIList | O | | 9.3.19 | This optional attribute is prepared for accommodating finer granularity of QoS flows with 5QI. | + +| Range bound | Explanation | +|--------------------------|--------------------------------------------------------------------------| +| maxnoofPartitionFlowList | Maximum no. of partitionFlowList supported for an E2 Node. Value is 128. | + +### 9.3.21 partitionList + +This IE is used to represent list of frequency partitions for per-slice interference control among cells as an O-RAN specific attribute added in O-NRCellDU defined in 8.8.2.2. The IE is used for O-DU scheduling algorithm to accommodate the interference control, configured by Near-RT RIC through analysis and control of per-slice interference. The frequency range of a partition is defined with two parameters of pOffsetToPointA and pNumberOfRBs, both expressed in units of RB. For example, assuming 15KHz subcarrier spacing for FR1, one RB is 180KHz and 60 KHz subcarrier spacing for FR2, one RB is 720KHz, according to 3GPP TS 38.211 [7], 4.4.4.1 and 4.4.4.2. Based on the per-slice-per-UE RSRP/CQI measurements collected from E2SM-KPM among multiple cells, Near-RT RIC analyzes possible aggressor cells of each slice in terms of reliability requirement in RAN Slice SLA assurance, and it allocates resources for aggressor cells not to use the same RB resources with the victim cell and informs O-DUs of their recommended resource allocations. The partitionList IE is for the DU's internal allocation of resources and need not be sent to the UE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|----------------------------|-----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| partitionList | | 1..<maxnoof PartitionList> | | | +| >partition Item | M | | | | +| >>pOffsetToPointA | M | | INTEGER | It defines the frequency offset between point A and the lowest subcarrier of the RB of a frequency partition. The unit is number of RBs as described above. Please refer to [7] clause 4.4.2. | +| >>pNumberOfRBs | M | | INTEGER | It defines the length of a frequency partition in contiguous resource block. The unit is number of RBs as described above. Please refer to [7] clause 4.4.2. | +| >>partitionFlowList | M | | 9.3.20 | | + +| Range bound | Explanation | +|----------------------|-------------------------------------------------------| +| maxnoofPartitionList | Maximum no. of partitionList supported. Value is 128. | + +### 9.3.22 policyType + +This IE This IE defines the NES policy type in the O-NESPolicy IOC which is defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| policyType | M | | ENUMERATED (ASM, TRX_CONTROL) | Please refer to clause 8.8.2.6, "policyType" attribute.<br><br>This IE should be included in the <i>Old Values of Attributes</i> IE when modifying existing O-NESPolicy for enabling association with the correct instance of the O-NESPolicy RAN configuration structure. | + +### 9.3.23 antennaMaskName + +This IE defines the antenna mask name in the O-NESPolicy IOC which is defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------|----------|-------|-----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| antennaMaskName | O | | STRING | <p>Please refer to clause 8.8.2.6, “antennaMaskName” attribute.</p> <p>This IE should be included in the <i>Old Values of Attributes</i> IE when modifying existing O-NESPolicy if it was present in it, for enabling association with the correct instance of the O-NESPolicy RAN configuration structure.</p> | + +### 9.3.24 antennaMask + +This IE defines the antenna mask value in the O-NESPolicy IOC which is defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| antennaMask | O | | STRING | <p>Please refer to clause 8.8.2.6, “antennaMask” attribute.</p> <p>This IE should be included in the <i>Old Values of Attributes</i> IE when modifying existing O-NESPolicy if it was present in it, for enabling association with the correct instance of the O-NESPolicy RAN configuration structure.</p> | + +### 9.3.25 sleepMode + +This IE defines the sleep mode type in the O-NESPolicy IOC which is defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| sleepMode | O | | ENUMERATED (SLEEP_MODE0, SLEEP_MODE1, SLEEP_MODE2, SLEEP_MODE3) | <p>Please refer to clause 8.8.2.6, “sleepMode” attribute.</p> <p>This IE should be included in the <i>Old Values of Attributes</i> IE when modifying existing O-NESPolicy if it was present in it, for enabling association with the correct instance of the O-NESPolicy RAN configuration structure.</p> | + +### 9.3.26 dataDir + +This IE defines the data direction in the O-NESPolicy IOC which is defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| dataDir | M | | ENUMERATED (DL,UL) | <p>Please refer to clause 8.8.2.6, “dataDir” attribute.</p> <p>This IE should be included in the <i>Old Values of Attributes</i> IE when modifying existing O-NESPolicy for enabling association with the correct instance of the O-NESPolicy RAN configuration structure.</p> | + +### 9.3.27 symbolMask + +This IE defines the symbol mask in the O-NESPolicy IOC which is defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|---------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| symbolMask | O | | INTEGER (0..2 <sup>14</sup> -1) | <p>Please refer to clause 8.8.2.6, “symbolMask” attribute.</p> <p>This IE should be included in the <i>Old Values of Attributes</i> IE when modifying existing O-NESPolicy if it was present in it, for enabling association with the correct instance of the O-NESPolicy RAN configuration structure.</p> | + +### 9.3.28 slotMask + +This IE defines the slot mask in the O-NESPolicy IOC which is defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| slotMask | O | | STRING | <p>Please refer to clause 8.8.2.6, “slotMask” attribute.</p> <p>This IE should be included in the <i>Old Values of Attributes</i> IE when modifying existing O-NESPolicy if it was present in it, for enabling association with the correct instance of the O-NESPolicy RAN configuration structure.</p> | + +### 9.3.29 validDuration + +This IE defines the valid duration in the O-NESPolicy IOC which is defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| validDuration | O | | INTEGER | <p>Please refer to clause 8.8.2.6, “validDuration” attribute.</p> <p>This IE should be included in the <i>Old Values of Attributes</i> IE when modifying existing O-NESPolicy if it was present in it, for enabling association with the correct instance of the O-NESPolicy RAN configuration structure.</p> | + +### 9.3.30 esObjective + +This IE defines the energy saving objective in the O-NESPolicy IOC which is defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------------------------------------------------------------------------------------|----------|-------|-----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| CHOICE EsObjective | | 0..1 | | <p>Please refer to clause 8.8.2.6, “EsObjective” attribute.</p> <p>This IE should be included in the <i>Old Values of Attributes</i> IE when modifying existing O-NESPolicy if it was present in it for enabling association with the correct instance of the O-NESPolicy RAN configuration structure.</p> | +| >targetEc | C | | REAL | <p>Target energy consumption, PEE.Energy (3GPP TS 28.552 [12], clause 5.1.1.19.3), of O-RU in kWh.</p> <p>See NOTE.</p> | +| >esPercentage | C | | INTEGER (0..100) | <p>Energy consumption reduction of O-RU in percentage. The energy consumption is measured based on method defined in 3GPP TS 28.552 [12], clause 5.1.1.19.3.</p> <p>See NOTE.</p> | +| NOTE: Between esPercentage, targetEc, one of the parameters is required, and only one of the parameters can be present. | | | | | + +### 9.3.31 onDurationTimer + +This IE defines the cell DTX/DRX duration. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|-------|-------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| CHOICE<br>onDurationTimer | | | | Please refer to clause 8.8.2.7. | +| >subMilliseconds | M | | INTEGER (1..31) | Indicates the length of cell DTX/DRX active duration in sub-ms. Value in multiples of 1/32 ms. Refer to 3GPP TS 38.331 [13], clause 6.3.2, “cellDTXDRX-onDurationTimer” description. | +| >milliseconds | M | | ENUMERATED (ms1, ms2, ms3, ms4, ms5, ms6, ms8, ms10, ms20, ms40, ms50, ms60, ms80, ms100, ms200, ms300, ms400, ms500, ms600, ms800, ms1000, ms1200, ms1600) | Indicates the length of cell DTX/DRX active duration in ms. Enum value ms1 corresponds to 1 ms, enum value ms2 corresponds to 2 ms, and so on. Refer to 3GPP TS 38.331 [13], clause 6.3.2, “cellDTXDRX-onDurationTimer” description. | + +### 9.3.32 cycleStartOffset + +This IE defines the cell DTX/DRX periodicity and offset. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|--------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| cycleStartOffset | | | | Please refer to clause 8.8.2.7. | +| >periodicity | M | | ENUMERATED (ms10, ms20, ms32, ms40, ms60, ms64, ms70, ms80, ms128, ms160, ms256, ms320, ms512, ms640, ms1024, ms1280, ms2048, ms2560, ms5120, ms10240) | Indicates the periodicity of the cell DTX/DRX pattern in ms. Enum value ms10 corresponds to 10 ms, enum value ms20 corresponds to 20 ms, and so on. Refer to 3GPP TS 38.331 [13], clause 6.3.2, “cellDTXDRX-CycleStartOffset” description. | +| >offset | M | | INTEGER (0.. 10239) | Indicates the subframe-level offset of the cell DTX/DRX pattern. Value in multiple of 1 ms. The offset value shall not exceed the value of the periodicity. Refer to 3GPP TS 38.331 [13], clause 6.3.2, “cellDTXDRX-CycleStartOffset” description. | + +### 9.3.33 oruUserPlaneConfiguration + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|--------------------------------------------------------------| +| txArrayList | O | | 9.3.34 | The txArrayList is a list of tx-arrays supported by the O-RU | +| rxArrayList | O | | 9.3.35 | The rxArrayList is a list of rx-arrays supported by the O-RU | + +### 9.3.34 txArrayList + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------|----------|-----------------------------------|-----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| txArrayList | | 1.. <i><maxnofTxArrays></i> | | Corresponds to the list "tx-arrays" in the o-ran-uplane-conf.yang YANG module provided by the O-RU. See O-RAN WG4.MP [10] clause 15.2.4 | +| >txArrayItem | M | | | | +| >>tName | M | | STRING | Unique name of the array | +| >>tNumberOfRows | M | | INTEGER (1..65535) | Number of rows array elements are shaped into – M. See O-RAN WG4.CUS [9] clause 12.5.3 | +| >>tNumberOfColumns | M | | INTEGER (1..65535) | Number of columns array elements are shaped into – N. See O-RAN WG4.CUS [9] clause 12.5.3 | +| >>tNumberOfArrayLayers | M | | INTEGER (1..255) | Number of array layers array elements are shaped into – Q. See O-RAN WG4.CUS [9] clause 12.5.3 | +| >>tHorizontalSpacing | O | | NUMBER | Average distance in meters between centers of nearby AE in horizontal direction (in array coordinates system). See O-RAN WG4.CUS [9] clause 12.5.3. Represented as decimal 64 with 5-digits fraction. | +| >>tVerticalSpacing | O | | NUMBER | Average distance in meters between centers of nearby AE in vertical direction (in array coordinates system). See O-RAN WG4.CUS [9] clause 12.5.3. Represented as decimal 64 with 5-digits fraction. | +| >>tNormalVectorDirection | O | | | | +| >>>tAzimuthAngle | O | | NUMBER | Azimuth angle - $\varphi$ (phi) - in degrees, counter-clockwise rotation around z-axis. Value 'zero' points to broad-side, value '90' points to y-axis. See O-RAN WG4.CUS [9] clause 12.5.2. Represented as decimal 64 with 4-digits fraction. | +| >>>tZenithAngle | O | | NUMBER | Zenith angle - $\theta$ (theta) - in degrees, counter-clockwise rotation around y-axis. Value 'zero' points to zenith, value '90' points to horizon. See O-RAN WG4.CUS [9] clause 12.5.2. Represented as decimal 64 with 4-digits fraction. | + +| | | | | | +|---------------------------------------|---|---------------------------------------|-----------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| >>tLeftmostBottomArrayElementPosition | O | | | Position of centre of the leftmost, bottom element of array in O-RU coordinate system. See O-RAN WG4.CUS [9] clause 12.5.3 | +| >>>tXAxis | O | | NUMBER | X dimension in meters of position of leftmost, bottom array element. Represented as decimal 64 with 4-digits fraction. | +| >>>tYAxis | O | | NUMBER | Y dimension in meters of position of leftmost, bottom array element. Represented as decimal 64 with 4-digits fraction. | +| >>>tZAxis | O | | NUMBER | Z dimension in meters of position of leftmost, bottom array element. Represented as decimal 64 with 4-digits fraction. | +| >>tPolarizationList | M | 1.. <i>maxnumberOfTxPolarizations</i> | | See O-RAN WG4.CUS [9] clause 12.5.3 | +| >>>tPolarizationItem | M | | | | +| >>>>tPolarizationIndex | M | | INTEGER (0..255) | Index (p) identifying the polarization out of the total P polarizations | +| >>>>tPolarizationType | M | | ENUMERATED (MINUS_45, ZERO, PLUS_45, PLUS_90} | Type of polarization supported by the array | +| >>tBandNumber | M | | INTEGER (1..1024) | Frequency band of the antenna array | +| >>tMaxGain | M | | NUMBER | Max gain in dB of RF path linked with array element (minimum over elements of array) or array layers. Represented as decimal 64 with 4-digits fraction. | +| >>tMinGain | O | | NUMBER | Min gain in dB of RF path linked with array element (maximum over elements of array) or array layers. Represented as decimal 64 with 4-digits fraction. | +| >>tIndependentPowerBudget | M | | BOOLEAN | If TRUE then every element of array has its own power budget independent from power budgets of other elements.<br><br>If FALSE then all elements of array that are at same row and column and have same polarization share power budget | + +| Range bound | Explanation | +|------------------------|--------------------------------------------------------| +| maxnoofTxArrays | Maximum no. of Tx arrays supported. Value is 256. | +| maxnoofTxPolarizations | Maximum no. of Tx polarizations supported. Value is 2. | + +### 9.3.35 rxArrayList + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------|----------|------------------------------------|-----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| rxArrayList | | 1.. <i><maxnoofRxArrays></i> | | Corresponds to the list "rx-arrays" in the o-ran-uplane-conf.yang YANG module provided by the O-RU. See O-RAN WG4.MP [10] clause 15.2.4 | +| >rxArrayItem | M | | | | +| >>rName | M | | STRING | Unique name of the array | +| >>rNumberOfRows | M | | INTEGER (1..65535) | Number of rows array elements are shaped into – M. See O-RAN WG4.CUS [9] clause 12.5.3 | +| >>rNumberOfColumns | M | | INTEGER (1..65535) | Number of columns array elements are shaped into – N. See O-RAN WG4.CUS [9] clause 12.5.3 | +| >>rNumberOfArrayLayers | M | | INTEGER (1..255) | Number of array layers array elements are shaped into - Q. See O-RAN WG4.CUS [9] clause 12.5.3 | +| >>rHorizontalSpacing | O | | NUMBER | Average distance in meters between centers of nearby AE in horizontal direction (in array coordinates system) . See O-RAN WG4.CUS [9] clause 12.5.3. Represented as decimal 64 with 5-digits fraction. | +| >>rVerticalSpacing | O | | NUMBER | Average distance in meters between centers of nearby AE in vertical direction (in array coordinates system) . See O-RAN WG4.CUS [9] clause 12.5.3. Represented as decimal 64 with 5-digits fraction. | +| >>rNormalVectorDirection | O | | | | +| >>>rAzimuthAngle | O | | NUMBER | Azimuth angle - $\varphi$ (phi) - in degrees, counter-clockwise rotation around z-axis. Value 'zero' points to broad-side, value '90' points to y-axis. See O-RAN WG4.CUS [9] clause 12.5.2. Represented as decimal 64 with 4-digits fraction. | + +| | | | | | +|---------------------------------------|---|-----------------------------------|-----------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| >>>rZenithAngle | O | | NUMBER | Zenith angle - $\theta$ (theta) - in degrees, counter-clockwise rotation around y-axis. Value 'zero' points to zenith, value '90' points to horizon. See O-RAN WG4.CUS [9] clause 12.5.2. Represented as decimal 64 with 4-digits fraction. | +| >>rLeftmostBottomArrayElementPosition | O | | | Position of centre of the leftmost, bottom element of array in O-RU coordinate system. See O-RAN WG4.CUS [9] clause 12.5.3 | +| >>>rXAxis | O | | NUMBER | X dimension in meters of position of leftmost, bottom array element. Represented as decimal 64 with 4-digits fraction. | +| >>>rYAxis | O | | NUMBER | Y dimension in meters of position of leftmost, bottom array element. Represented as decimal 64 with 4-digits fraction. | +| >>>rZAxis | O | | NUMBER | Z dimension in meters of position of leftmost, bottom array element. Represented as decimal 64 with 4-digits fraction. | +| >>rPolarizationList | M | 1.. <i>maxnoofRxPolarizations</i> | | | +| >>>rPolarizationItem | M | | | | +| >>>>rPolarizationIndex | M | | INTEGER (0..255) | Index (p) identifying the polarization out of the total P polarizations | +| >>>>rPolarizationType | M | | ENUMERATED (MINUS_45, ZERO, PLUS_45, PLUS_90) | Type of polarization supported by the array | +| >>rBandNumber | M | | INTEGER (1..1024) | Frequency band of the antenna array | +| >>rGainCorrectionRange | M | | | | +| >>>rMax | M | | NUMBER | Maximum allowed value in dB. Represented as decimal 64 with 4-digits fraction. | +| >>>rMin | M | | NUMBER | Minimum allowed value in dB. Represented as decimal 64 with 4-digits fraction. | + +| Range bound | Explanation | +|------------------------|--------------------------------------------------------| +| maxnoofRxArrays | Maximum no. of Rx arrays supported. Value is 256. | +| maxnoofRxPolarizations | Maximum no. of Rx polarizations supported. Value is 2. | + +### 9.3.36 perfObjectiveList + +This IE defines the list of performance objectives in O-NESPolicy which is defined in clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------|----------|-------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| perfObjectiveList | | 1..<maxnoof Objectives> | | This IE should be included in the <i>Old Values of Attributes</i> IE when modifying existing O-NESPolicy if it was present in it for enabling association with the correct instance of the O-NESPolicy RAN configuration structure | +| >perfObjective | M | | | | +| >> pLMNInfoList | O | | 9.3.15 | A list of pair of pLMNID and sNSSAI which are used to uniquely identify one or more applicable slice(s). If absent, the configuration applies to all slice(s). | +| >> fiveQIValue | M | | INTEGER (0..255) | Identify the corresponding service type in standardized 5QI values for which the performance objective to be configured.<br><br>See 3GPP TS 23.501, clause 5.7.4 and 3GPP TS 28.541, clause 5.4 | +| >> maxNgbFlowBr | O | | STRING | Maximum aggregated bit rate for all the Non-GBR flows having the same fiveQIValue to limit the total throughput of a certain Non-GBR service type in a cell in order to create more sleep opportunities to save energy.<br><br>Note: this is different from the Maximum Flow Bit Rate for GBR flows defined in clause 5.7.2.5 of 3GPP TS 23.501.<br><br>It is formatted as follows:<br><br>Pattern: '^d+(\.d+)?(bps Kbps Mbps Gbps Tbps)\$', see TS 29.512.<br><br>Examples:<br><br>"125 Mbps", "0.125 Gbps", "125000 Kbps".<br><br>AllowedValues: N/A. | +| >>flowBrAvgWindow | O | | INTEGER (0..4095) | Indicate the averaging window (in unit of ms) of a 5QI representing the duration over which the maxNgbFlowBr shall be calculated. | +| >>maxPd | O | | INTEGER (0..1023) | It indicates an upper bound of packet delay allowed between O-DU F1U end point and UE (in unit of 0.5ms) for a service type identified by the 5QI. The value shall be smaller than the E2E Packet Delay Budget (including delay in UPF) configured in the QoS characteristics (see 3GPP TS 23.501), subtracting CN packet delay and packet delay experienced in O-CU-UP and F1U interface.<br><br>O-DU can try to delay the traffic scheduling up to the upper bound, to concentrate the transmission in fewer number of slots, | + +| | | | | | +|------------|---|--|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | leaving transmission gaps to save energy through ASM (switching off O-RU RF components during the gaps). | +| >>targetPd | O | | INTEGER<br>(0..1023) | <p>It indicates a target packet delay in average between O-DU F1U end point and UE (in unit of 0.5ms) for a 5QI. The value shall be smaller than the E2E Packet Delay Budget configured in the QoS characteristics and smaller than maxPd if configured.</p> <p>O-DU can try to delay the traffic scheduling using the target delay, to concentrate the transmission in fewer number of slots, leaving transmission gaps to save energy through ASM (switching off O-RU RF components during the gaps).</p> | + +| Range bound | Explanation | +|-------------------|----------------------------------------------------------------| +| maxnoofObjectives | Maximum no. of performance objectives supported. Value is 128. | + +### 9.3.37 oruCapabilities + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|-------|-----------------------|-----------------------------------------------------------------------| +| energySavingCapabilityCommonInfo | O | | 9.3.38 | O-RU capabilities common to both TRX Control and Advanced Sleep Mode. | +| asmCapabilityInfo | O | | 9.3.39 | O-RU ASM capability info | +| trxControlCapabilityInfo | O | | 9.3.40 | O-RU TRX Control capability info | + +### 9.3.38 energySavingCapabilityCommonInfo + +This IE is used to represent O-RU capability information common to both ASM and TRX Control. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------|----------|-------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------| +| ST8-ready-message-supported | M | | BOOL | <p>The capability of the cell to support the "ready" message via clause Type 8 command.</p> <p>Refer to [10], clause 20.4.1</p> | +| sleep-duration-extension-supported | M | | BOOL | <p>The capability of the cell to support the extension of a defined sleep interval.</p> <p>Refer to [10], clause 20.4.1</p> | +| emergency-wake-up-command-supported | M | | BOOL | <p>The capability of the cell to support emergency wake-up procedure.</p> <p>Refer to [10], clause 20.4.1</p> | + +### 9.3.39 asmCapabilityInfo + +This IE is used to represent O-RU ASM capability information. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------|----------|---------------------|-----------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| sleepModes | | $1..<maxnoofModes>$ | | A list of sleep modes supported by the O-RU which are reported with their corresponding wakeupDuration values. | +| >sleepMode | M | | | | +| >>sleepModeType | M | | ENUMERATED (SLEEP_MODE0, SLEEP_MODE1, SLEEP_MODE2, SLEEP_MODE3) | This value indicates the sleep modes supported by the O-RU for a particular [tr]x-array.<br><br>Refer to [10], clause 20.4.1 | +| >>wakeupDuration | M | | INTEGER (0...2 <sup>32</sup> -1) | This value indicates the reported wake-up time (in microseconds) for a particular sleep mode for a particular [tr]x-array.<br><br>Refer to [10], clause 20.4.1 | +| >>wakeupDurationGuranteed | M | | BOOL | The capability of the O-RU to guarantee full wake-up operation within the time reported in wakeupDuration.<br><br>Refer to [10], clause 20.4.1 | +| definedDurationSleepSupported | M | | BOOL | The capability of the O-RU to support the defined sleep functionality.<br><br>Refer to [10], clause 20.4.1 | +| undefinedDurationSleepSupported | M | | BOOL | The capability of the O-RU to support the un-defined sleep functionality.<br><br>Refer to [10], clause 20.4.1 | + +| Range bound | Explanation | +|--------------|---------------------------------------------------| +| maxnoofModes | Maximum no. of sleep modes, supported value is 4. | + +### 9.3.40 trxControlCapabilityInfo + +This IE is used to represent O-RU TRX control capability information. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------|----------|---------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| supportedTrxControlMasks | | $1..<maxnoofMasks>$ | | A list of TRX control configurations that are supported by the O-RU which are reported with their corresponding maskName and antennaMask values.<br><br>The absence of the list supported-trx-control-masks indicates that any combination of antenna mask is supported by the O-RU for a particular [tr]x-array.<br><br>Refer to [10], clause 20.3.1 | +| >supportedTrxControlMask | M | | | | +| >> maskName | M | | STRING | Name of the supported antenna mask<br><br>Refer to [10], clause 20.3.1 | + +| | | | | | +|---------------------------------|---|-------------------|-----------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| >> antennaMask | M | | INTEGER<br>(0..2 <sup>64</sup> -1) | Supported antenna mask value.<br><br>Refer to [10], clause 20.3.1 | +| sleepModes | | 1..<maxnoofModes> | | A list of sleep modes supported by the O-RU which are reported with their corresponding wakeup duration values. | +| >sleepMode | M | | | | +| >>sleepModeType | M | | ENUMERATED<br>(SLEEP_MODE0,<br>SLEEP_MODE1,<br>SLEEP_MODE2,<br>SLEEP_MODE3) | This value indicates the sleep modes supported by the O-RU for a particular [tr]x-array.<br><br>Refer to [10], clause 20.3.1. | +| >>wakeupDuration | M | | INTEGER<br>(0...2 <sup>32</sup> -1) | This value indicates the reported wakeup time (in microseconds) for each individual sleep mode for the TRX(s) corresponding to a particular [tr]x-array.<br><br>Refer to [10], clause 20.3.1. | +| >>wakeupDurationGuaranteed | M | | BOOL | The capability of the O-RU to guarantee the complete wake-up operation or to become active within the duration reported in wakeupDuration.<br><br>Refer to [10], clause 20.3.1. | +| definedDurationSleepSupported | M | | BOOL | The capability of the O-RU to support the defined sleep functionality.<br><br>Refer to [10], clause 20.3.1. | +| undefinedDurationSleepSupported | M | | BOOL | The capability of the O-RU to support the un-defined sleep functionality.<br><br>Refer to [10], clause 20.3.1. | + +| Range bound | Explanation | +|--------------|-------------------------------------------------------| +| maxnoofModes | Maximum no. of sleep modes, supported value is 4. | +| maxnoofMasks | Maximum no. of antenna masks, supported value is 128. | + +## 9.4 JSON Schema + +### 9.4.1 General + +E2SM-CCC JSON Schema definitions conforms to JSON Draft 07 and Draft 2019-09. Clause 9.4.2 contains the JSON Schema definitions of the E2SM information elements and the RAN Configuration Structures to be carried within the E2AP [3] protocol messages as an OCTET STRING with JSON encoding. + +If an E2SM information element carried as an OCTET STRING in an E2AP [3] message that is not constructed as defined in this specification is received, this shall be considered as an encoding error and if applicable, the respective *Cause* IE shall be included in the response message. + +### 9.4.2 JSON Schema Definitions + +``` +{ + "openapi": "3.0.1", + "info": { + "title": "E2SM-CCC", + "version": "5.0.0", + "description": "OAS 3.0.1 specification compatible schema for O-RAN WG3 E2SM-CCC" + } +} +``` + +``` + +}, +"paths": {}, +"components": { + "schemas": { + "GnbId": { + "type": "integer", + "minimum": 0, + "maximum": 4294967295 + }, + "GnbIdLength": { + "type": "integer", + "minimum": 22, + "maximum": 32 + }, + "GnbName": { + "type": "string", + "maxLength": 150 + }, + "GnbDuId": { + "type": "number", + "minimum": 0, + "maximum": 68719476735 + }, + "GnbCuUpId": { + "type": "number", + "minimum": 0, + "maximum": 68719476735 + }, + "Sst": { + "type": "integer", + "maximum": 255 + }, + "Snssai": { + "type": "object", + "properties": { + "sst": { + "$ref": "#/components/schemas/Sst" + }, + "sd": { + "type": "string" + } + } + }, + "SnssaiList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/Snssai" + } + }, + "Mcc": { + "type": "string", + "pattern": "[0-9]{3}" + }, + "Mnc": { + "type": "string", + "pattern": "[0-9]{3}|[0-9]{2}" + }, + "PlmnId": { + "type": "object", + "properties": { + "mcc": { + "$ref": "#/components/schemas/Mcc" + }, + "mnc": { + "$ref": "#/components/schemas/Mnc" + } + } + }, + "PlmnIdList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/PlmnId" + } + }, + "PlmnInfo": { + "type": "object", + +``` + +``` + + "properties": { + "plmnId": { + "$ref": "#/components/schemas/PlmnId" + }, + "snssai": { + "$ref": "#/components/schemas/Snssai" + } + } + }, + "PlmnInfoList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/PlmnInfo" + } + }, + "GGnbId": { + "type": "string", + "pattern": "^[0-9]{3}[0-9]{2,3}-(22|23|24|25|26|27|28|29|30|31|32)-[0-9]{1,10}" + }, + "GEnbId": { + "type": "string", + "pattern": "^[0-9]{3}[0-9]{2,3}-(18|20|21|22)-[0-9]{1,7}" + }, + "GGnbIdList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/GGnbId" + } + }, + "GEnbIdList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/GEnbId" + } + }, + "NrPci": { + "type": "integer", + "minimum": 0, + "maximum": 503 + }, + "NrTac": { + "type": "integer", + "minimum": 0, + "maximum": 16777215 + }, + "OperationalState": { + "type": "string", + "enum": [ + "ENABLED", + "DISABLED" + ] + }, + "AdministrativeState": { + "type": "string", + "enum": [ + "LOCKED", + "SHUTTINGDOWN", + "UNLOCKED" + ] + }, + "CellState": { + "type": "string", + "enum": [ + "IDLE", + "INACTIVE", + "ACTIVE" + ] + }, + "CyclicPrefix": { + "type": "string", + "enum": [ + "15", + "30", + "60", + "120" + ] + } + +``` + +``` + +}, +"BwpContext": { + "type": "string", + "enum": [ + "DL", + "UL", + "SUL" + ] +}, +"IsInitialBwp": { + "type": "string", + "enum": [ + "INITIAL", + "OTHER", + "SUL" + ] +}, +"SubCarrierSpacing": { + "type": "integer", + "enum": [ + 15, + 30, + 60, + 120 + ] +}, +"SsbPeriodicity": { + "type": "integer", + "enum": [ + 5, + 10, + 20, + 40, + 80, + 160 + ] +}, +"SsbDuration": { + "type": "integer", + "enum": [ + 1, + 2, + 3, + 4, + 5 + ] +}, +"SsbSubCarrierSpacing": { + "type": "integer", + "enum": [ + 15, + 30, + 120, + 240 + ] +}, +"ResourceType": { + "type": "string", + "enum": [ + "PRB_DL", + "PRB_UL", + "DRB", + "RRC" + ] +}, +"RrmPolicyMember": { + "type": "object", + "properties": { + "plmnId": { + "$ref": "#/components/schemas/PlmnId" + }, + "snssai": { + "$ref": "#/components/schemas/Snssai" + } + } +}, +}, + +``` + +``` + +"RrmPolicyMemberList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/RrmPolicyMember" + } +}, +"5QiList": { + "type": "array", + "items": {"type": "integer"} +}, +"PartitionFlowList": { + "type": "array", + "items": { + "type": "object", + "properties": { + "snssai": { + "$ref": "#/components/schemas/Snssai" + }, + "plmnId": { + "$ref": "#/components/schemas/PlmnId" + }, + "5qiList": { + "$ref": "#/components/schemas/5QiList" + } + } + } +}, +"PartitionList": { + "type": "array", + "items": { + "type": "object", + "properties": { + "pOffsetToPointA": {"type": "integer"}, + "pNumberOfRBs": {"type": "integer"}, + "partitionFlowList": { + "$ref": "#/components/schemas/PartitionFlowList" + } + } + } +}, +"EsObjective": { + "oneOf": [ + { + "type": "object", + "properties": { + "targetEc": { + "type": "number" + } + } + }, + { + "type": "object", + "properties": { + "esPercentage": { + "type": "integer", + "minimum": 0, + "maximum": 100 + } + } + } + ] +}, +"PerfObjective": { + "type": "object", + "properties": { + "plmnInfoList": {"$ref": "#/components/schemas/PlmnInfoList"}, + "fiveQIValue": {"type": "integer", "minimum": 0, "maximum": 255}, + "maxNgbRFlowBr": {"type": "string"}, + "flowBrAvgWindow": {"type": "integer", "minimum": 0, "maximum": 4095}, + "maxPd": {"type": "integer", "minimum": 0, "maximum": 1023}, + "targetPd": {"type": "integer", "minimum": 0, "maximum": 1023} + }, + "required": ["plmnInfoList", "fiveQIValue"] +}, +"PerfObjectiveList": { + +``` + +``` + + "type": "array", + "items": { + "$ref": "#/components/schemas/PerfObjective" + } + }, + "SleepMode": { + "type": "object", + "properties": { + "sleepModeType": { + "type": "string", + "enum": ["SLEEP_MODE0", " SLEEP_MODE1", " SLEEP_MODE2", " SLEEP_MODE3"] + }, + "wakeupDuration": {"type": "integer"}, + "wakeupDurationGuaranteed": {"type": "boolean"} + }, + "required": ["sleepModeType", "wakeupDuration", "wakeupDurationGuaranteed"] + }, + "SleepModes": { + "type": "array", + "items": { + "$ref": "#/components/schemas/SleepMode" + } + }, + "SupportedTrxControlMask": { + "type": "object", + "properties": { + "maskName": {"type": "string"}, + "antennaMask": {"type": "integer"} + }, + "required": ["maskName", "antennaMask"] + }, + "SupportedTrxControlMasks": { + "type": "array", + "items": { + "$ref": "#/components/schemas/SupportedTrxControlMask" + } + }, + "EnergySavingCapabilityCommonInfo": { + "type": "object", + "properties": { + "ST8-ready-message-supported": {"type": "boolean"}, + "sleep-duration-extension-supported": {"type": "boolean"}, + "emergency-wake-up-command-supported": {"type": "boolean"} + }, + "required": ["ST8-ready-message-supported", " sleep-duration-extension-supported", "emergency-wake-up-command-supported"] + }, + "AsmCapabilityInfo": { + "type": "object", + "properties": { + "sleepModes": {"$ref": "#/components/schemas/SleepModes"}, + "definedDurationSleepSupported": {"type": "boolean"}, + "undefinedDurationSleepSupported": {"type": "boolean"} + }, + "required": ["sleepModes", "definedDurationSleepSupported", "undefinedDurationSleepSupported"] + }, + "TrxControlCapabilityInfo": { + "type": "object", + "properties": { + "supportedTrxControlMasks": {"$ref": "#/components/schemas/SupportedTrxControlMasks"}, + "sleepModes": {"$ref": "#/components/schemas/SleepModes"}, + "definedDurationSleepSupported": {"type": "boolean"}, + "undefinedDurationSleepSupported": {"type": "boolean"} + }, + "required": ["supportedTrxControlMasks", "sleepModes", "definedDurationSleepSupported", "undefinedDurationSleepSupported"] + }, + "OruCapabilities": { + "type": "object", + "properties": { + +``` + +``` + + "energySavingCapabilityCommonInfo": {"$ref": +"#/components/schemas/EnergySavingCapabilityCommonInfo"}, + "asmCapabilityInfo": {"$ref": "#/components/schemas/AsmCapabilityInfo"}, + "trxControlCapabilityInfo": {"$ref": "#/components/schemas/TrxControlCapabilityInfo"} + }, + "OnDurationTimer": { + "oneOf": [ + { + "type": "integer", + "minimum": 1, + "maximum": 31 + }, + { + "type": "string", + "enum": ["ms1", "ms2", "ms3", "ms4", "ms5", "ms6", "ms8", "ms10", "ms20", "ms40", "ms50", +"ms60", "ms80", "ms100", "ms200", "ms300", "ms400", "ms500", "ms600", "ms800", "ms1000", +"ms1200", "ms1600"] + } + ] + }, + "CycleStartOffset": { + "type": "object", + "properties": { + "periodicity": { + "type": "string", + "enum": ["ms10", "ms20", "ms32", "ms40", "ms60", "ms64", "ms70", "ms80", "ms128", "ms160", +"ms256", "ms320", "ms512", "ms640", "ms1024", "ms1280", "ms2048", "ms2560", "ms5120", +"ms10240"] + }, + "offset": { + "type": "integer", + "minimum": 0, + "maximum": 10239 + } + } + }, + "tPolarizationItem": { + "type": "object", + "properties": { + "tPolarizationIndex": { + "type": "integer", + "minimum": 0, + "maximum": 255 + }, + "tPolarizationType": { + "type": "string", + "enum": [ + "MINUS_45", + "ZERO", + "PLUS_45", + "PLUS_90" + ] + } + } + }, + "required": ["tPolarizationIndex", "tPolarizationType"] +}, + "rPolarizationItem": { + "type": "object", + "properties": { + "rPolarizationIndex": { + "type": "integer", + "minimum": 0, + "maximum": 255 + }, + "rPolarizationType": { + "type": "string", + "enum": [ + "MINUS_45", + "ZERO", + "PLUS_45", + +``` + +``` + + "PLUS_90" + ] +} +}, +"required": ["rPolarizationIndex", "rPolarizationType"] +}, +"TxArrayItem": { + "type": "object", + "properties": { + "tName": { + "type": "string" + }, + "tNumberOfRows": { + "type": "integer", + "minimum": 1, + "maximum": 65535 + }, + "tNumberOfColumns": { + "type": "integer", + "minimum": 1, + "maximum": 65535 + }, + "tNumberOfArrayLayers": { + "type": "integer", + "minimum": 1, + "maximum": 255 + }, + "tHorizontalSpacing": { + "type": "number" + }, + "tVerticalSpacing": { + "type": "number" + }, + "tNormalVectorDirection": { + "type": "object", + "properties": { + "tAzimuthAngle": { + "type": "number" + }, + "tZenithAngle": { + "type": "number" + } + } + }, + "tLeftmostBottomArrayElementPosition": { + "type": "object", + "properties": { + "tXAxis": { + "type": "number" + }, + "tYAxis": { + "type": "number" + }, + "tZAxis": { + "type": "number" + } + } + }, + "tPolarizationList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/tPolarizationItem" + } + }, + "tBandNumber": { + "type": "integer", + "minimum": 1, + "maximum": 1024 + }, + "tMaxGain": { + "type": "number" + } + } +} + +``` + +``` + + }, + "tMinGain": { + "type": "number" + }, + "tIndependentPowerBudget": { + "type": "boolean" + } + }, + "required": ["tName", "tNumberOfRows", "tNumberOfColumns", "tNumberOfArrayLayers", + "tPolarizationList", "tBandNumber", "tMaxGain", "tIndependentPowerBudget"] +}, +"RxArrayItem": { + "type": "object", + "properties": { + "rName": { + "type": "string" + }, + "rNumberOfRows": { + "type": "integer", + "minimum": 1, + "maximum": 65535 + }, + "rNumberOfColumns": { + "type": "integer", + "minimum": 1, + "maximum": 65535 + }, + "rNumberOfArrayLayers": { + "type": "integer", + "minimum": 1, + "maximum": 255 + }, + "rHorizontalSpacing": { + "type": "number" + }, + "rVerticalSpacing": { + "type": "number" + }, + "rNormalVectorDirection": { + "type": "object", + "properties": { + "rAzimuthAngle": { + "type": "number" + }, + "rZenithAngle": { + "type": "number" + } + } + }, + "rLeftmostBottomArrayElementPosition": { + "type": "object", + "properties": { + "rXAxis": { + "type": "number" + }, + "rYAxis": { + "type": "number" + }, + "rZAxis": { + "type": "number" + } + } + }, + "rPolarizationList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/rPolarizationItem" + } + }, + "rBandNumber": { + "type": "integer", + +``` + +``` + + "minimum": 1, + "maximum": 1024 + }, + "rGainCorrectionRange": { + "type": "object", + "properties": { + "rMax": { + "type": "number" + }, + "rMin": { + "type": "number" + } + } + } +}, +"required": ["rName", "rNumberOfRows", "rNumberOfColumns", "rNumberOfArrayLayers", +"rPolarizationList", "rBandNumber", "rGainCorrectionRange", "rMax", "rMin"] +}, +"TxArrayList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/TxArrayItem" + } +}, +"RxArrayList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/RxArrayItem" + } +}, +"OruUserPlaneConfiguration": { + "type": "object", + "properties": { + "txArrayList": { + "$ref": "#/components/schemas/TxArrayList" + }, + "rxArrayList": { + "$ref": "#/components/schemas/RxArrayList" + } + } +}, +"O-GnbCuCpFunction": { + "type": "object", + "properties": { + "gnbId": {"$ref": "#/components/schemas/GnbId"}, + "gnbIdLength": {"$ref": "#/components/schemas/GnbIdLength"}, + "gnbCuName": {"$ref": "#/components/schemas/GnbName"}, + "plmnId": {"$ref": "#/components/schemas/PlmnId"}, + "x2BlockList": {"$ref": "#/components/schemas/GEnbIdList"}, + "xnBlockList": {"$ref": "#/components/schemas/GGnbIdList"}, + "x2AllowList": {"$ref": "#/components/schemas/GEnbIdList"}, + "xnAllowList": {"$ref": "#/components/schemas/GGnbIdList"}, + "x2HOBBlockList": {"$ref": "#/components/schemas/GEnbIdList"}, + "xnHOBBlockList": {"$ref": "#/components/schemas/GGnbIdList"} + } +}, +"O-GnbCuUpFunction": { + "type": "object", + "properties": { + "gnbId": {"$ref": "#/components/schemas/GnbId"}, + "gnbIdLength": {"$ref": "#/components/schemas/GnbIdLength"}, + "gnbCuUpId": {"$ref": "#/components/schemas/GnbCuUpId"}, + "plmnInfoList": {"$ref": "#/components/schemas/PlmnInfoList"} + } +}, +"O-GnbDuFunction": { + "type": "object", + "properties": { + "gnbDuId": {"$ref": "#/components/schemas/GnbDuId"}, + "gnbDuName": {"$ref": "#/components/schemas/GnbName"}, + "gnbId": {"$ref": "#/components/schemas/GnbId"}, + "gnbIdLength": {"$ref": "#/components/schemas/GnbIdLength"} + } +} + +``` + +``` + +}, +"O-NrCellCu": { + "type": "object", + "properties": { + "cellLocalId": {"type": "integer"}, + "plmnInfoList": {"$ref": "#/components/schemas/PlmnInfoList"} + } +}, +"O-NrCellDu": { + "type": "object", + "properties": { + "cellLocalId": {"type": "integer"}, + "operationalState": {"$ref": "#/components/schemas/OperationalState"}, + "administrativeState": {"$ref": "#/components/schemas/AdministrativeState"}, + "cellState": {"$ref": "#/components/schemas/CellState"}, + "plmnInfoList": {"$ref": "#/components/schemas/PlmnInfoList"}, + "nrPci": {"$ref": "#/components/schemas/NrPci"}, + "nrTac": {"$ref": "#/components/schemas/NrTac"}, + "arfcnDL": {"type": "integer"}, + "arfcnUL": {"type": "integer"}, + "arfcnSUL": {"type": "integer"}, + "bSChannelBwDL": {"type": "integer"}, + "ssbFrequency": { + "type": "integer", + "minimum": 0, + "maximum": 3279165 + }, + "ssbPeriodicity": {"$ref": "#/components/schemas/SsbPeriodicity"}, + "ssbSubCarrierSpacing": {"$ref": "#/components/schemas/SsbSubCarrierSpacing"}, + "ssbOffset": { + "type": "integer", + "minimum": 0, + "maximum": 159 + }, + "ssbDuration": {"$ref": "#/components/schemas/SsbDuration"}, + "bSChannelBwUL": {"type": "integer"}, + "bSChannelBwSUL": {"type": "integer"}, + "bwpList": {"type": "array", "items": {"$ref": "#/components/schemas/O-Bwp"}}, + "partitionList": {"$ref": "#/components/schemas/PartitionList"} + } +}, +"O-RRMPolicyRatio": { + "type": "object", + "properties": { + "resourceType": {"$ref": "#/components/schemas/ResourceType"}, + "rRMPolicyMemberList": {"$ref": "#/components/schemas/RrmPolicyMemberList"}, + "rRMPolicyMaxRatio": {"type": "integer"}, + "rRMPolicyMinRatio": {"type": "integer"}, + "rRMPolicyDedicatedRatio": {"type": "integer"} + } +}, +"O-Bwp": { + "type": "object", + "properties": { + "bwpContext": {"$ref": "#/components/schemas/BwpContext"}, + "isInitialBwp": {"$ref": "#/components/schemas/IsInitialBwp"}, + "subCarrierSpacing": {"$ref": "#/components/schemas/SubCarrierSpacing"}, + "cyclicPrefix": {"$ref": "#/components/schemas/CyclicPrefix"}, + "startRB": {"type": "integer"}, + "numberOfRBs": {"type": "integer"} + } +}, +"O-CESManagementFunction": { + "type": "object", + "properties": { + "cesSwitch": {"type": "boolean"}, + "energySavingState": { + "type": "string", + "enum": ["isNotEnergySaving", "isEnergySaving"] + }, + "energySavingControl": { + "type": "string", + "enum": ["toBeEnergySaving", "toBeNotEnergySaving"] + } + } +} + +``` + +``` + + }, + "O-NESPolicy": { + "type": "object", + "properties": { + "policyType": { + "type": "string", + "enum": ["ASM", "TRX_CONTROL"] + }, + "antennaMaskName": { + "type": "string" + }, + "antennaMask": { + "type": "string" + }, + "sleepMode": { + "type": "string", + "enum": ["SLEEP_MODE0", "SLEEP_MODE1", "SLEEP_MODE2", "SLEEP_MODE3"] + }, + "dataDir": { + "type": "string", + "enum": ["DL", "UL"] + }, + "symbolMask": { + "type": "integer", + "minimum": 0, + "maximum": 16383 + }, + "slotMask": { + "type": "string" + }, + "validDuration": { + "type": "integer" + }, + "esObjective": { + "$ref": "#/components/schemas/EsObjective" + }, + "perfObjectiveList": { + "$ref": "#/components/schemas/PerfObjectiveList" + } + } + }, + "O-CellDTXDRXConfig": { + "type": "object", + "properties": { + "onDurationTimer": { + "$ref": "#/components/schemas/OnDurationTimer" + }, + "cycleStartOffset": { + "$ref": "#/components/schemas/CycleStartOffset" + }, + "slotOffset": { + "type": "integer", + "minimum": 0, + "maximum": 31 + }, + "configType": { + "type": "string", + "enum": ["DTX", "DRX", "DTXDRX"] + }, + "activationStatus": { + "type": "string", + "enum": ["ACTIVATED", "DEACTIVATED"] + }, + "llActivation": { + "type": "string", + "enum": ["ENABLED", "DISABLED"] + } + } + }, + "O-RUInfo": { + "type": "object", + "properties": { + "oruUserPlaneConfiguration": {"$ref": "#/components/schemas/OruUserPlaneConfiguration"}, + +``` + +``` + + "oruCapabilities": {"$ref": "#/components/schemas/OruCapabilities"} + }, + "E2SM-CCC-RAN-Configuration-Structure": { + "oneOf": [ + { + "$ref": "#/components/schemas/O-GnbCuCpFunction" + }, + { + "$ref": "#/components/schemas/O-GnbCuUpFunction" + }, + { + "$ref": "#/components/schemas/O-GnbDuFunction" + }, + { + "$ref": "#/components/schemas/O-NrCellCu" + }, + { + "$ref": "#/components/schemas/O-NrCellDu" + }, + { + "$ref": "#/components/schemas/O-RRMPolicyRatio" + }, + { + "$ref": "#/components/schemas/O-Bwp" + }, + { + "$ref": "#/components/schemas/O-CESManagementFunction" + }, + { + "$ref": "#/components/schemas/O-NESPolicy" + }, + { + "$ref": "#/components/schemas/O-CellDTXDRXConfig" + }, + { + "$ref": "#/components/schemas/O-RUInfo" + } + ] + }, + "RIC-Indication-Header": { + "type": "object", + "properties": { + "indicationHeaderFormat": {"$ref": "#/components/schemas/IndicationHeaderFormat"} + }, + "required": ["indicationHeaderFormat"] + }, + "IndicationHeaderFormat": { + "oneOf": [ + { + "$ref": "#/components/schemas/E2SM-CCC-IndicationHeaderFormat1" + } + ] + }, + "E2SM-CCC-IndicationHeaderFormat1": { + "type": "object", + "properties": { + "indicationReason": {"enum": ["uponSubscription", "uponChange", "periodic"] }, + "eventTime": {"type": "string"} + }, + "required": ["indicationReason", "eventTime"] + }, + "RIC-Indication-Message": { + "type": "object", + "properties": { + "indicationMessageFormat": {"$ref": "#/components/schemas/IndicationMessageFormat"} + }, + "required": ["indicationMessageFormat"] + }, + "IndicationMessageFormat": { + "oneOf": [ + { + "$ref": "#/components/schemas/E2SM-CCC-IndicationMessageFormat1" + } + ] + } + +``` + +``` + + "$ref": "#/components/schemas/E2SM-CCC-IndicationMessageFormat2" + } +} +}, +"E2SM-CCC-IndicationMessageFormat1": { + "type": "object", + "properties": { + "listOfConfigurationStructuresReported": {"$ref": +"#/components/schemas/ListOfConfigurationsReported"} + }, + "required": ["listOfConfigurationStructuresReported"] +}, +"ListOfConfigurationsReported": { + "type": "array", + "items": { + "$ref": "#/components/schemas/ConfigurationStructure" + } +}, +"ConfigurationStructure": { + "type": "object", + "properties": { + "changeType": { "enum": ["none", "modification", "addition", "deletion"] }, + "ranConfigurationStructureName": { "type": "string" }, + "valuesOfAttributes": { "$ref": "#/components/schemas/ValuesOfAttributes" }, + "oldValuesOfAttributes": { "$ref": "#/components/schemas/ValuesOfAttributes" } + }, + "required": ["changeType", "ranConfigurationStructureName", "valuesOfAttributes"] +}, +"ValuesOfAttributes": { + "type": "object", + "properties": { + "ranConfigurationStructure": { "$ref": "#/components/schemas/E2SM-CCC-RAN-Configuration- +Structure" } + }, + "required": ["ranConfigurationStructure"] +}, +"E2SM-CCC-IndicationMessageFormat2": { + "type": "object", + "properties": { + "listOfCellsReported": {"$ref": "#/components/schemas/ListOfCellsReported"} + }, + "required": ["listOfCellsReported"] +}, +"ListOfCellsReported": { + "type": "array", + "items": { + "$ref": "#/components/schemas/CellReported" + } +}, +"CellReported": { + "type": "object", + "properties": { + "cellGlobalId": {"$ref": "#/components/schemas/CellGlobalId" }, + "listOfConfigurationStructuresReported": {"$ref": +"#/components/schemas/ListOfConfigurationsReported"} + }, + "required": ["cellGlobalId", "listOfConfigurationStructuresReported"] +}, +"CellGlobalId": { + "type": "object", + "oneOf": [ + { + "$ref": "#/components/schemas/NR-CGI" + }, + { + "$ref": "#/components/schemas/EUTRA-CGI" + } + ] +}, +"NR-CGI": { + "type": "object", + "properties": { + "plmnIdentity": {"$ref": "#/components/schemas/PlmnId" }, + "nrCellIdentity": {"$ref": "#/components/schemas/NRCellIdentity"} + }, + "required": ["plmnIdentity", "nrCellIdentity"] +} + +``` + +``` + +}, +"NRCellIdentity": { + "type": "string", + "pattern": "^[A-Za-f0-9]{9}$" +}, +"EUTRA-CGI": { + "type": "object", + "properties": { + "plmnIdentity": {"$ref": "#/components/schemas/PlmnId"}, + "eUTRACellIdentity": {"$ref": "#/components/schemas/EUTRACellIdentity"} + }, + "required": ["plmnIdentity", "eUTRACellIdentity"] +}, +"EUTRACellIdentity": { + "type": "string" +}, +"RIC-Control-Header": { + "type": "object", + "properties": { + "controlHeaderFormat": {"$ref": "#/components/schemas/ControlHeaderFormat"} + }, + "required": ["controlHeaderFormat"] +}, +"ControlHeaderFormat": { + "oneOf": [ + { + "$ref": "#/components/schemas/E2SM-CCC-ControlHeaderFormat1" + } + ] +}, +"E2SM-CCC-ControlHeaderFormat1": { + "type": "object", + "properties": { + "ricStyleType": { "type": "integer" } + }, + "required": ["ricStyleType"] +}, +"RIC-Control-Message": { + "type": "object", + "properties": { + "controlMessageFormat": {"$ref": "#/components/schemas/ControlMessageFormat"} + }, + "required": ["controlMessageFormat"] +}, +"ControlMessageFormat": { + "oneOf": [ + { + "$ref": "#/components/schemas/E2SM-CCC-ControlMessageFormat1" + }, + { + "$ref": "#/components/schemas/E2SM-CCC-ControlMessageFormat2" + } + ] +}, +"E2SM-CCC-ControlMessageFormat1": { + "type": "object", + "properties": { + "listOfConfigurationStructures": {"$ref": "#/components/schemas/ListOfConfigurationStructures"} + }, + "required": ["listOfConfigurationStructures"] +}, +"ListOfConfigurationStructures": { + "type": "array", + "items": { + "$ref": "#/components/schemas/ConfigurationStructureWrite" + } +}, +"ConfigurationStructureWrite": { + "type": "object", + "properties": { + "ranConfigurationStructureName": {"type": "string"}, + "oldValuesOfAttributes": {"$ref": "#/components/schemas/ValuesOfAttributes"}, + "newValuesOfAttributes": { "$ref": "#/components/schemas/ValuesOfAttributes" } + }, + "required": ["ranConfigurationStructureName", "oldValuesOfAttributes", "newValuesOfAttributes"] +}, + +``` + +``` + +"E2SM-CCC-ControlMessageFormat2": { + "type": "object", + "properties": { + "listOfCellsControlled": {"$ref": "#/components/schemas/ListOfCellsControlled"} + }, + "required": ["listOfCellsControlled"] +}, +"ListOfCellsControlled": { + "type": "array", + "items": { + "$ref": "#/components/schemas/CellControlled" + } +}, +"CellControlled": { + "type": "object", + "properties": { + "cellGlobalId": {"$ref": "#/components/schemas/CellGlobalId" }, + "listOfConfigurationStructures": {"$ref": "#/components/schemas/ListOfConfigurationStructures"} + }, + "required": ["cellGlobalId", "listOfConfigurationStructures"] +}, +"RANFunctionDefinition": { + "type": "object", + "properties": { + "ranFunctionName": {"$ref": "#/components/schemas/RANFunctionName" }, + "listOfSupportedNodeLevelConfigurationStructures": {"$ref": "#/components/schemas/ListOfSupportedRANConfigurationStructures"}, + "listOfCellsForRANFunctionDefinition": {"$ref": "#/components/schemas/ListOfCellsForRANFunctionDefinition"} + }, + "required": ["ranFunctionName"] +}, +"RANFunctionName": { + "type": "object", + "properties": { + "ranFunctionShortName": {"type": "string"}, + "ranFunctionServiceModelOID": {"type": "string"}, + "ranFunctionDescription": {"type": "string"}, + "ranFunctionInstance": {"type": "integer"} + }, + "required": ["ranFunctionShortName", "ranFunctionServiceModelOID", "ranFunctionDescription"] +}, +"ListOfSupportedRANConfigurationStructures": { + "type": "array", + "items": { + "$ref": "#/components/schemas/RANConfigurationStructure" + } +}, +"RANConfigurationStructure": { + "type": "object", + "properties": { + "ranConfigurationStructureName": {"type": "string"}, + "listOfSupportedAttributes": {"$ref": "#/components/schemas/ListOfSupportedAttributes"} + }, + "required": ["ranConfigurationStructureName"] +}, +"ListOfSupportedAttributes": { + "type": "array", + "items": { + "$ref": "#/components/schemas/Attribute" + } +}, +"Attribute": { + "type": "object", + "properties": { + "attributeName": {"type": "string"}, + "supportedServices": {"$ref": "#/components/schemas/RICServices"} + }, + "required": ["attributeName", "supportedServices"] +}, +"RICServices": { + "type": "object", + "properties": { + "eventTrigger": {"$ref": "#/components/schemas/EventTrigger"}, + "reportService": {"$ref": "#/components/schemas/ReportService"}, + "insertService": {"$ref": "#/components/schemas/InsertService"}, + +``` + +``` + + "controlService": {"$ref": "#/components/schemas/ControlService"}, + "policyService": {"$ref": "#/components/schemas/PolicyService"}, + "queryService": {"$ref": "#/components/schemas/QueryService"} + }, + "EventTrigger": { + "type": "object", + "properties": { + "listOfSupportedEventTriggerStyles": {"$ref": +"#!/components/schemas/ListOfSupportedEventTriggerStyles"} + }, + "required": ["listOfSupportedEventTriggerStyles"] + }, + "ListOfSupportedEventTriggerStyles": { + "type": "array", + "items": { + "$ref": "#/components/schemas/EventTriggerStyle" + } + }, + "EventTriggerStyle": { + "type": "object", + "properties": { + "eventTriggerStyleType": {"type": "integer"}, + "eventTriggerStyleName": {"type": "string"}, + "eventTriggerFormatType": {"type": "integer"} + }, + "required": ["eventTriggerStyleType", "eventTriggerStyleName", "eventTriggerFormatType"] + }, + "ReportService": { + "type": "object", + "properties": { + "listOfSupportedReportStyles": {"$ref": "#/components/schemas/ListOfSupportedReportStyles"} + }, + "required": ["listOfSupportedReportStyles"] + }, + "ListOfSupportedReportStyles": { + "type": "array", + "items": { + "$ref": "#/components/schemas/ReportStyle" + } + }, + "ReportStyle": { + "type": "object", + "properties": { + "reportServiceStyleType": {"type": "integer"}, + "reportServiceStyleName": {"type": "string"}, + "listOfSupportedEventTriggerStylesForReportStyle": { + "type": "array", + "items": { + "$ref": "#/components/schemas/EventTriggerStyleType" + } + }, + "reportServiceActionDefinitionFormatType": {"type": "integer"}, + "reportServiceIndicationHeaderFormatType": {"type": "integer"}, + "reportServiceIndicationMessageFormatType": {"type": "integer"} + }, + "required": ["reportServiceStyleType", "reportServiceStyleName", +"listOfSupportedEventTriggerStylesForReportStyle", "reportServiceActionDefinitionFormatType", +"reportServiceIndicationHeaderFormatType", "reportServiceIndicationMessageFormatType"] + }, + "EventTriggerStyleType": { + "type": "object", + "properties": { + "eventTriggerStyleType": {"type": "integer"} + }, + "required": ["eventTriggerStyleType"] + }, + "InsertService": { + "type": "object" + }, + "ControlService": { + "type": "object", + "properties": { + "listOfSupportedControlStyles": {"$ref": "#/components/schemas/ListOfSupportedControlStyles"} + }, + "required": ["listOfSupportedControlStyles"] + } + +``` + +``` + +}, +"ListOfSupportedControlStyles": { + "type": "array", + "items": { + "$ref": "#/components/schemas/ControlStyle" + } +}, +"ControlStyle": { + "type": "object", + "properties": { + "controlServiceStyleType": {"type": "integer"}, + "controlServiceStyleName": {"type": "string"}, + "controlServiceHeaderFormatType": {"type": "integer"}, + "controlServiceMessageFormatType": {"type": "integer"}, + "ricCallProcessIDFormatType": {"type": "integer"}, + "controlServiceControlOutcomeFormatType": {"type": "integer"} + }, + "required": ["controlServiceStyleType", "controlServiceStyleName", +"controlServiceHeaderFormatType", "controlServiceMessageFormatType", +"controlServiceControlOutcomeFormatType"] +}, +"PolicyService": { + "type": "object" +}, +"QueryService": { + "type": "object", + "properties": { + "listOfSupportedQueryStyles": {"$ref": "#/components/schemas/ListOfSupportedQueryStyles"} + }, + "required": ["listOfSupportedQueryStyles"] +}, +"ListOfSupportedQueryStyles": { + "type": "array", + "items": { + "$ref": "#/components/schemas/QueryStyle" + } +}, +"QueryStyle": { + "type": "object", + "properties": { + "queryServiceStyleType": {"type": "integer"}, + "queryServiceStyleName": {"type": "string"}, + "queryServiceHeaderFormatType": {"type": "integer"}, + "queryServiceDefinitionFormatType": {"type": "integer"}, + "queryServiceOutcomeFormatType": {"type": "integer"} + }, + "required": ["queryServiceStyleType", "queryServiceStyleName", "queryServiceHeaderFormatType", +"queryServiceDefinitionFormatType", "queryServiceOutcomeFormatType"] +}, +"ListOfCellsForRANFunctionDefinition": { + "type": "array", + "items": { + "$ref": "#/components/schemas/CellForRANFunctionDefinition" + } +}, +"CellForRANFunctionDefinition": { + "type": "object", + "properties": { + "cellGlobalID": {"$ref": "#/components/schemas/NR-CGI"}, + "listOfSupportedCellLevelRANConfigurationStructures": {"$ref": +"#/components/schemas/ListOfSupportedRANConfigurationStructures"} + }, + "required": ["cellGlobalID"] +}, +"RICEventTriggerDefinition": { + "type": "object", + "properties": { + "eventTriggerDefinitionFormat": {"$ref": "#/components/schemas/EventTriggerDefinitionFormat"} + }, + "required": ["eventTriggerDefinitionFormat"] +}, +"EventTriggerDefinitionFormat": { + "oneOf": [ + { + +``` + +``` + + "$ref": "#/components/schemas/E2SM-CCC-EventTriggerDefinition-Format1" + }, + { + "$ref": "#/components/schemas/E2SM-CCC-EventTriggerDefinition-Format2" + }, + { + "$ref": "#/components/schemas/E2SM-CCC-EventTriggerDefinition-Format3" + } +] +}, +"E2SM-CCC-EventTriggerDefinition-Format1": { + "type": "object", + "properties": { + "listOfNodeLevelConfigurationStructuresForEventTrigger": {"$ref": +"#/components/schemas/ListOfRANConfigurationStructuresForEventTrigger"} + }, + "required": ["listOfNodeLevelConfigurationStructuresForEventTrigger"] +}, +"ListOfRANConfigurationStructuresForEventTrigger": { + "type": "array", + "items": { + "$ref": "#/components/schemas/RANConfigurationStructureForEventTrigger" + } +}, +"RANConfigurationStructureForEventTrigger": { + "type": "object", + "properties": { + "ranConfigurationStructureName": {"type": "string"}, + "listOfAttributes": { + "type": "array", + "items": { + "type": "string" + } + } + }, + "required": ["ranConfigurationStructureName"] +}, +"E2SM-CCC-EventTriggerDefinition-Format2": { + "type": "object", + "properties": { + "listOfCellLevelConfigurationStructuresForEventTrigger": { + "$ref": "#/components/schemas/ListOfCellLevelConfigurationStructuresForEventTrigger" + } + }, + "required": ["listOfCellLevelConfigurationStructuresForEventTrigger"] +}, +"ListOfCellLevelConfigurationStructuresForEventTrigger": { + "type": "array", + "items": { + "$ref": "#/components/schemas/CellLevelConfigurationStructureForEventTrigger" + } +}, +"CellLevelConfigurationStructureForEventTrigger": { + "type": "object", + "properties": { + "cellGlobalId": {"$ref": "#/components/schemas/NR-CGI"}, + "listOfRANConfigurationStructuresForEventTrigger": {"$ref": +"#/components/schemas/ListOfRANConfigurationStructuresForEventTrigger"} + }, + "required": ["listOfRANConfigurationStructuresForEventTrigger"] +}, +"E2SM-CCC-EventTriggerDefinition-Format3": { + "type": "object", + "properties": { + "period": {"type": "integer"} + }, + "required": ["period"] +}, +"RICActionDefinition": { + "type": "object", + "properties": { + "ricStyleType": {"type": "integer"}, + "actionDefinitionFormat": {"$ref": "#/components/schemas/ActionDefinitionFormat"} + }, + "required": ["ricStyleType", "actionDefinitionFormat"] +}, + +``` + +``` + +"ActionDefinitionFormat": { + "oneOf": [ + { + "$ref": "#/components/schemas/E2SM-CCC-ActionDefinitionFormat1" + }, + { + "$ref": "#/components/schemas/E2SM-CCC-ActionDefinitionFormat2" + } + ] +}, +"E2SM-CCC-ActionDefinitionFormat1": { + "type": "object", + "properties": { + "listOfNodeLevelRANConfigurationStructuresForADF": {"$ref": +"#/components/schemas/ListOfRANConfigurationStructuresForADF"} + }, + "required": ["listOfNodeLevelRANConfigurationStructuresForADF"] +}, +"ListOfRANConfigurationStructuresForADF": { + "type": "array", + "items": { + "$ref": "#/components/schemas/RANConfigurationStructureForADF" + } +}, +"RANConfigurationStructureForADF": { + "type": "object", + "properties": { + "reportType": {"enum": ["all", "change"]}, + "ranConfigurationStructureName": {"type": "string"}, + "listOfAttributes": { + "type": "array", + "items": { + "$ref": "#/components/schemas/AttributeName" + } + } + }, + "required": ["reportType", "ranConfigurationStructureName"] +}, +"AttributeName": { + "type": "object", + "properties": { + "attributeName": {"type": "string"} + }, + "required": ["attributeName"] +}, +"E2SM-CCC-ActionDefinitionFormat2": { + "type": "object", + "properties": { + "listOfCellConfigurationsToBeReportedForADF": {"$ref": +"#/components/schemas/ListOfCellConfigurationsToBeReportedForADF"} + }, + "required": ["listOfCellConfigurationsToBeReported"] +}, +"ListOfCellConfigurationsToBeReportedForADF": { + "type": "array", + "items": { + "$ref": "#/components/schemas/CellConfigurationToBeReportedForADF" + } +}, +"CellConfigurationToBeReportedForADF": { + "type": "object", + "properties": { + "cellGlobalId": {"$ref": "#/components/schemas/NR-CGI"}, + "listOfCellLevelRANConfigurationStructuresForADF": { + "$ref": "#/components/schemas/ListOfRANConfigurationStructuresForADF" + } + } +}, +"RIC-Control-Outcome": { + "type": "object", + "properties": { + "controlOutcomeFormat": {"$ref": "#/components/schemas/ControlOutcomeFormat"} + }, + "required": ["controlOutcomeFormat"] +}, +"ControlOutcomeFormat": { + +``` + +``` + + "oneOf": [ + { + "$ref": "#/components/schemas/E2SM-CCC-ControlOutcomeFormat1" + }, + { + "$ref": "#/components/schemas/E2SM-CCC-ControlOutcomeFormat2" + } + ] + }, + "E2SM-CCC-ControlOutcomeFormat1": { + "type": "object", + "properties": { + "receivedTimestamp": {"type": "string"}, + "ranConfigurationStructuresAcceptedList": {"$ref": "#/components/schemas/RanConfigurationStructuresAcceptedList"}, + "ranConfigurationStructuresFailedList": {"$ref": "#/components/schemas/RanConfigurationStructuresFailedList"} + } + }, + "RanConfigurationStructuresAcceptedList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/ConfigurationStructureAccepted" + } + }, + "ConfigurationStructureAccepted": { + "type": "object", + "properties": { + "ranConfigurationStructureName": {"type": "string"}, + "oldValuesOfAttributes": {"$ref": "#/components/schemas/ValuesOfAttributes"}, + "currentValuesOfAttributes": {"$ref": "#/components/schemas/ValuesOfAttributes"}, + "appliedTimestamp": {"type": "string"} + }, + "required": ["ranConfigurationStructureName", "oldValuesOfAttributes", "currentValuesOfAttributes"] + }, + "RanConfigurationStructuresFailedList": { + "type": "array", + "items": { + "$ref": "#/components/schemas/ConfigurationStructureFailed" + } + }, + "ConfigurationStructureFailed": { + "type": "object", + "properties": { + "ranConfigurationStructureName": {"type": "string"}, + "oldValuesOfAttributes": {"$ref": "#/components/schemas/ValuesOfAttributes"}, + "requestedValuesOfAttributes": {"$ref": "#/components/schemas/ValuesOfAttributes"}, + "cause": {"$ref": "#/components/schemas/Cause"} + }, + "required": ["ranConfigurationStructureName", "oldValuesOfAttributes", "requestedValuesOfAttributes", "cause"] + }, + "Cause": { + "type": "string", + "enum": [ + "NotSupported", + "NotAvailable", + "IncompatibleState", + "JsonError", + "SemanticError", + "Unspecified" + ] + }, + "E2SM-CCC-ControlOutcomeFormat2": { + "type": "object", + "properties": { + "receivedTimestamp": {"type": "string"}, + "listOfCellsForControlOutcome": {"$ref": "#/components/schemas/ListOfCellsForControlOutcome"} + }, + "required": ["listOfCellsForControlOutcome"] + }, + "ListOfCellsForControlOutcome": { + "type": "array", + "items": { + "$ref": "#/components/schemas/CellControlOutcome" + } + } + +``` + +``` + + } + }, + "CellControlOutcome": { + "type": "object", + "properties": { + "cellGlobalId": {"$ref": "#/components/schemas/CellGlobalId" }, + "ranConfigurationStructuresAcceptedList": {"$ref": +"#/components/schemas/RanConfigurationStructuresAcceptedList"}, + "ranConfigurationStructuresFailedList": {"$ref": +"#/components/schemas/RanConfigurationStructuresFailedList"} + }, + "required": ["cellGlobalId"] + }, + "RIC-Query-Header": { + "type": "object", + "properties": { + "queryHeaderFormat": {"$ref": "#/components/schemas/QueryHeaderFormat"} + }, + "required": ["queryHeaderFormat"] + }, + "QueryHeaderFormat": { + "oneOf": [ + { + "$ref": "#/components/schemas/E2SM-CCC-QueryHeaderFormat1" + } + ] + }, + "E2SM-CCC-QueryHeaderFormat1": { + "type": "object", + "properties": { + "ricStyleType": { "type": "integer" } + }, + "required": ["ricStyleType"] + }, + "RIC-Query-Definition": { + "type": "object", + "properties": { + "queryDefinitionFormat": {"$ref": "#/components/schemas/QueryDefinitionFormat"} + }, + "required": ["queryDefinitionFormat"] + }, + "QueryDefinitionFormat": { + "oneOf": [ + { + "$ref": "#/components/schemas/E2SM-CCC-QueryDefinitionFormat1" + }, + { + "$ref": "#/components/schemas/E2SM-CCC-QueryDefinitionFormat2" + } + ] + }, + "E2SM-CCC-QueryDefinitionFormat1": { + "type": "object", + "properties": { + "listOfNodelevelRanConfigurationStructuresForQuery": {"$ref": +"#/components/schemas/ListOfNodelevelRanConfigurationStructuresForQuery"} + }, + "required": ["listOfNodelevelRanConfigurationStructuresForQuery"] + }, + "ListOfNodelevelRanConfigurationStructuresForQuery": { + "type": "array", + "items": { + "$ref": "#/components/schemas/NodelevelRanConfigurationStructuresForQuery" + } + }, + "NodelevelRanConfigurationStructuresForQuery": { + "type": "object", + "properties": { + "ranConfigurationStructureName": {"type": "string"}, + "listOfAttributes": { + "type": "array", + "items": { + "$ref": "#/components/schemas/AttributeName" + } + } + } + }, + +``` + +``` + + "required": ["ranConfigurationStructureName"] + }, + "E2SM-CCC-QueryDefinitionFormat2": { + "type": "object", + "properties": { + "listOfCellsToBeQueriedForQuery": {"$ref": +"#/components/schemas/ListOfCellsToBeQueriedForQuery"} + }, + "required": ["listOfCellsToBeQueriedForQuery"] + }, + "ListOfCellsToBeQueriedForQuery": { + "type": "array", + "items": { + "$ref": "#/components/schemas/CellsToBeQueried" + } + }, + "CellsToBeQueried": { + "type": "object", + "properties": { + "cellGlobalId": {"$ref": "#/components/schemas/CellGlobalId" }, + "listOfCelllevelConfigurationStructuresForQuery": {"$ref": +"#/components/schemas/ListOfCelllevelConfigurationStructuresForQuery"} + }, + "required": ["listOfCelllevelConfigurationStructuresForQuery"] + }, + "ListOfCelllevelConfigurationStructuresForQuery": { + "type": "array", + "items": { + "$ref": "#/components/schemas/CelllevelConfigurationStructuresForQuery" + } + }, + "CelllevelConfigurationStructuresForQuery": { + "type": "object", + "properties": { + "ranConfigurationStructureName": {"type": "string"}, + "listOfAttributes": { + "type": "array", + "items": { + "$ref": "#/components/schemas/AttributeName" + } + } + }, + "required": ["ranConfigurationStructureName"] + }, + "RIC-Query-Outcome": { + "type": "object", + "properties": { + "queryDefinitionFormat": {"$ref": "#/components/schemas/QueryOutcomeFormat"} + }, + "required": ["queryOutcomeFormat"] + }, + "QueryOutcomeFormat": { + "oneOf": [ + { + "$ref": "#/components/schemas/E2SM-CCC-QueryOutcomeFormat1" + }, + { + "$ref": "#/components/schemas/E2SM-CCC-QueryOutcomeFormat2" + } + ] + }, + "E2SM-CCC-QueryOutcomeFormat1": { + "type": "object", + "properties": { + "listOfConfigurationStructuresToBeReportedForQuery": {"$ref": +"#/components/schemas/ListOfConfigurationStructuresToBeReportedForQuery"} + }, + "required": ["listOfConfigurationStructuresToBeReportedForQuery"] + }, + "ListOfConfigurationStructuresToBeReportedForQuery": { + "type": "array", + "items": { + "$ref": "#/components/schemas/ConfigurationStructuresToBeReportedForQuery" + } + }, + +``` + +``` + +"ConfigurationStructuresToBeReportedForQuery": { + "type": "object", + "properties": { + "ranConfigurationStructureName": {"type": "string"}, + "valuesOfAttributes": { "$ref": "#/components/schemas/ValuesOfAttributes" } + }, + "required": ["ranConfigurationStructureName", "valuesOfAttributes"] +}, +"E2SM-CCC-QueryOutcomeFormat2": { + "type": "object", + "properties": { + "listOfCellsToBeReportedForQuery": {"$ref": +"#/components/schemas/ListOfCellsToBeReportedForQuery"} + }, + "required": ["listOfCellsToBeReportedForQuery"] +}, +"ListOfCellsToBeReportedForQuery": { + "type": "array", + "items": { + "$ref": "#/components/schemas/CellsToBeReportedForQuery" + } +}, +"CellsToBeReportedForQuery": { + "type": "object", + "properties": { + "cellGlobalId": {"$ref": "#/components/schemas/CellGlobalId" }, + "listOfConfigurationStructuresToBeReportedForQuery": {"$ref": +"#/components/schemas/ListOfConfigurationStructuresToBeReportedForQuery"} + }, + "required": ["cellGlobalId", "listOfConfigurationStructuresToBeReportedForQuery"] +} +} +} +} + +``` + +## 9.5 Message transfer syntax + +Void + +# --- 10 Handling of Unknown, Unforeseen and Erroneous Protocol Data + +Void + +# --- Annex A (informative): Examples on IE Contents + +Void + +# Annex (informative): Change history/Change request (history) + +| Date | Revision | Description | +|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.02.25 | 00.00.01 | Initial skeleton | +| 2022.03.10 | 00.00.02 | Editorial changes for removal of text from clauses to minimize initial content | +| 2022.06.07 | 00.00.03 | Editorial changes related to E2SM name update from “Cell Control” to “Cell Configuration and Control”<br><br>Addition of CRs agreed in WG3#139:<br>- JNPR-2022.02.25-WG3-CR-0004-E2SM-CC-RANFunctionServiceModelDescription-v2<br>- JNPR-2022.02.25-WG3-CR-0005-E2SM-CC-RANFunctionName-v2<br><br>Addition of CRs agreed in WG3#147:<br>- JNPR.AO-2022.03.04-WG3-CR-0007-E2SM-CCC-EventTriggerStyle1-v4<br>- JNPR.AO-2022.03.04-WG3-CR-0008-E2SM-CCC-EventTriggerDefinitionFormat1-v4 | +| 2022.06.28 | 00.00.04 | Addition of CRs agreed in WG3#149:<br>- JNPR.AO-2022.03.09-WG3-CR-0009-E2SM-CCC-ReportService-v3.docx<br>- JNPR.AO-2022.03.09-WG3-CR-0010-E2SM-CCC-ActionDefinition-v3.docx<br>- JNPR.AO-2022.03.15-WG3-CR-0011-E2SM-CCC-Section8-v3.docx<br>- JNPR.AO-2022.05.23-WG3-CR-0012-E2SM-CCC-RICIndication-v1.docx | +| 2022.07.05 | 00.00.05 | Addition of CRs agreed in WG3#151:<br>- JNPR-2022.02.25-WG3-CR-0006-E2SM-CCC-RICControlServices-v2<br>- JNPR-2022.06.22-WG3-CR-0013-E2SM-CCC-RICControl-v2 | +| 2022.07.18 | 00.00.06 | Addition of CRs agreed in WG3#153:<br>- JNPR.AO-2022.06.30-WG3-CR-0014-E2SM-CCC-- ControlRelatedConfigurationStructures-v3<br>- JNPR-2022.07.05-WG3-CR-0015-E2SM-CCC-Section9.3-v1<br>- JNPR.AO-2022.07.07-WG3-CR-0016-E2SM-CCC-RANFunctionDefinition-v2<br><br>Editorial changes to correct clause number cross-references within the document | +| 2022.07.19 | 00.00.07 | Addition of CRs agreed in WG3#154:<br>- JNPR.AO-2022.07.08-WG3-CR-0017-E2SM-CCC-JSON Schemas-v1<br><br>Editorial changes (consistent upper/lower case definitions across clauses 8, 9 and JSON schema definitions, enum vs enumerations, removal of extra empty lines, etc.) | +| 2022.07.21 | 00.00.08 | Update of the document to comply with the new O-RAN Technical Spec template | +| 2022.07.29 | 00.00.09 | Addressed WG3 review comments | +| 2022.08.02 | 01.00 | Final version 01.00 | +| 2022.11.04 | 01.00.01 | Addition of CRs agreed in WG3#164:<br>- JNPR-2022.10.13-WG3-CR-0018-E2SM-CCC-ControlOutcomeJSONSchema<br>- JNPR-2022.10.13-WG3-CR-0019-E2SM-CCC-JSONSchemaFixes<br><br>Note: This version contains non-backward compatible change with respect to v01.00. | +| 2022.11.18 | 01.00.02 | Editorial changes to add R003 to file name, update copyright year and update of clause 7.1: Corrected IE name to align with clause 9.2.2.1 RAN Function Definition IE definition. | +| 2022.11.18 | 01.01 | Final version 01.01 | +| 2023.03.15 | 01.01.01 | Aligned to latest O-RAN document template<br>Addition of CR agreed in WG3#175:<br>- FJT-2023.01.18-WG3-CR-0001-E2SM-CCC InterferenceControl-v04.docx | +| 2023.06.30 | 01.01.02 | Addition of CRs agreed in WG3#177 and WG3#182:<br>- FJT-2023.03.16-WG3-CR-0003-E2SM-CCC_InterferenceControl_JSONSchema_update-v01.docx<br>- JNPR.AO-2023.03.22-WG3-CR-0020-E2SM-CCC-VersionClarificationFor3GPPReferences-v3.docx | +| 2023.07.28 | 01.01.03 | Editorial changes to address comments received during WG3 approval process. | +| 2023.07.30 | 02.00 | Final version 02.00 | +| 2023.11.03 | 02.00.01 | Initial version towards v03.00<br>Addition of CR agreed in WG3#197:<br>- RSYS.AO-2023.08.22-WG3-CR-0002-E2SM-CCC-Energy Saving Report-v03 | + +| | | | +|------------|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.11.03 | 02.00.02 | Addition of CR agreed in WG3#199:<br>- NEC-2023.08.31-WG3-CR-0021-E2SM-CCC JSON Schema Definitions IE - listOfCellsControlled | +| 2023.11.03 | 02.00.03 | Addition of CR agreed in WG3#201:<br>- JNPR.AO-2023.09.11-WG3-CR-0021-E2SM-CCC-RANFunctionDefinitionStage2-v1 | +| 2023.11.03 | 02.00.04 | Addition of CR agreed in WG3#202:<br>- RSYS.AO-2023.10.04-WG3-CR-0002-E2SM-CCC-JSON Schema for celllevel Energy Saving-v01 | +| 2023.11.17 | 02.00.05 | WG3 review comments are addressed, and approval is completed. | +| 2023.11.17 | 02.00.06 | All changes accepted, clean version. | +| 2023.11.18 | 03.00 | Final version 03.00 | +| 2024.03.21 | 03.00.01 | Initial version towards v04.00<br>Addition of CRs agreed in WG3#216, WG3#217 and WG3#218:<br>- NEC-2023.12.14-WG3-CR-0028-E2SM-CCC_clarification_on_ReportType_v01<br>- RMI.AO-2023.09.21-WG3-CR-0003-E2SM-CCC-Energy Saving ASM and TRX Control-v09<br>- RMI.AO-2024.02.29-WG3-CR-0005-E2SM-CCC-JSON Schema for ASM and TRX Control Energy Saving-v04<br>- NOK.AO-2024.03.13-WG3-CR-0001-E2SM-CCC clause 3.1 and 4.3-v02 | +| 2024.03.31 | 03.00.02 | Editorial changes to align to O-RAN TS template v01.01<br>Editorial changes based on remarks during WG3 approval. | +| 2024.03.31 | 04.00 | Final version 04.00 | +| 2024.11.11 | 04.00.01 | Initial version towards v05.00<br>Aligned to O-RAN TS template v02.01<br>Addition of CRs agreed in WG3#233, WG3#234, WG3#235, WG3#237, WG#239<br>- INT.AO-2024.05.30-WG3-CR-0028-E2SM-CCC-Cell DTX DRX-v06<br>- COT-2024.05.24-WG3-CR-0005-E2SM-CCC-MU-MIMO-Optimization-O-RU-Config-v04<br>- INT.AO-2024.08.07-WG3-CR-0029-E2SM-CCC-JSON schema for cell DTX DRX-v01<br>- NEC-2024.07.24-WG3-CR-0029-E2SM-CCC OCTET STRING format -v03<br>- COT-2024.08.12-WG3-CR-0011-E2SM-CCC-JSON-Schema-Definitions-for-O-RU-Config-v02<br>- NEC.AO-2024.07.18-WG3-CR-0021-E2SM-CCC RIC Query -v08<br>- NEC-2024.07.24-WG3-CR-0030-E2SM-CCC NRCellIdentity JSON Schema length-v03 | +| 2024.11.25 | 04.00.02 | Aligned to O-RAN Working Procedures v04.00<br>Editorial changes to add missing range bound tables for query definition and outcome formats<br>Addition of CRs agreed in WG3#229, WG3#234, WG3#245<br>- RMI.AO-2024.04.01-WG3-CR-0006-E2SM-CCC-Adding Performance Objective Parameters in O-NESPolicy-v05<br>- RMI.AO-2024.02.12-WG3-CR-0004-E2SM-CCC-Energy Saving ASM and TRX Control-O-RU-Capability-Report-v03<br>- JNPR-2024.11.11-WG3-CR-0034-E2SM-CCC_oruUserPlaneConfig-Correction-v01<br>- JNPR-2024.11.11-WG3-CR-0035-E2SM-CCC_Query Service- JSONSchemaCorrection-v01<br>- JNPR-2024.11.11-WG3-CR-0036-E2SM-CCC_ODR_Update_of_References-v01<br>- JNPR-2024.11.11-WG3-CR-0037-E2SM-CCC_ODR_Update_of_Clause_5-v01<br>- RMI.AO-2024.11.10-WG3-CR-0007-E2SM-CCC-JSON Schema for performance objecitves-v01<br>- RMI.AO-2024.11.10-WG3-CR-0008-E2SM-CCC-JSON Schema for oruCapability-v02<br>- JNPR-2024.11.12-WG3-CR-0038-E2SM-CCC_Update-of-FFS-wording-v01<br>- JNPR-2024.11.12-WG3-CR-0039-E2SM-CCC_ODR_Update-of-section-wording-v01<br>- JNPR-2024.11.19-WG3-CR-0040-E2SM-CCC_JSONSchemaVersionUpdateAndCorrection-v01 | +| 2024.12.06 | 04.00.03 | Editorial changes based on remarks during WG3 approval. | +| 2024.12.06 | 05.00 | Final version 05.00 | \ No newline at end of file diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/07fb0cf167a589fac41ca2b17145bdaf_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/07fb0cf167a589fac41ca2b17145bdaf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1c93039b8d9f00ea25403852546212c4e541d13a --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/07fb0cf167a589fac41ca2b17145bdaf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5c9093784674568ffb75ea13a46138595c1baa98968ad020214fe735cc2571de +size 4513 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/2748c0f209100f8c0d55548f8306af71_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/2748c0f209100f8c0d55548f8306af71_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6de9aee720152dc5f20d2cc270847ce83548cfbd --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/2748c0f209100f8c0d55548f8306af71_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a78710392f58b5fa41d10c3c79793405ba12198e246065499831676255baf1cd +size 4524 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/2c5ca2ff66f77f9883244b78ec195181_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/2c5ca2ff66f77f9883244b78ec195181_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..856584c5b574d8a266d5eae691e0614697cdad43 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/2c5ca2ff66f77f9883244b78ec195181_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:42e4c64d45fd3b39c682399bf2c8717353a24ac440ad04002ba7ddfb72671084 +size 4528 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/3278a8a64af0266447dbdb59e9016bbc_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/3278a8a64af0266447dbdb59e9016bbc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c2f756d80a1ff53513d33e94f89a599cee69ab1d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/3278a8a64af0266447dbdb59e9016bbc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e1b11d6beda7effe81ddf8e191d0061868bd69de90675c10b7bdb4324d515573 +size 65843 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/617af00d12bfe7c9c0b3bc15eb590fcf_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/617af00d12bfe7c9c0b3bc15eb590fcf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e34c67cadd27168c2e190ccd2a2628d246f0df16 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/617af00d12bfe7c9c0b3bc15eb590fcf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:92d1b8f252e63ec8931e9510ba135002b530d676e98151ff4ed8312360b94941 +size 4579 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/6866072099568759f3328d8a130800c8_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/6866072099568759f3328d8a130800c8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c0ba753a0f2db982cd24cd9b01991ee3fb872966 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/6866072099568759f3328d8a130800c8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6f04d4fae8bfe0c76e4c97fc5e4bb805d00da6119ac3f22d28d4a9155e6e0800 +size 4487 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82827af191c934857f3a5a97842fa19fb4aa5978 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54f690c723a011f67b244eeda5cca1f67e7a7784e122d72a637cea1ca968c8f4 +size 4531 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/8a2de5b4f0214480220791d5df502772_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/8a2de5b4f0214480220791d5df502772_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ab8747bcf11ee5cf47dcdd3c8b54b7c708088eff --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/8a2de5b4f0214480220791d5df502772_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e27f16daf351d3488d0b74dd3d08e156d509b6380babeb760d41bf766bebaa24 +size 4527 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/8dc558aea299c81eded6b651f1d643ad_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/8dc558aea299c81eded6b651f1d643ad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1cbfeb391ba39b93fb35a13ee35cb44639afb58c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/8dc558aea299c81eded6b651f1d643ad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5fd971f1dae831e4d28ea5c2ff41d39c9f49407bcd6fbfb177363f951ff2e429 +size 4558 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/a4bc5ab364837d749e7891c9013fdc3b_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/a4bc5ab364837d749e7891c9013fdc3b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d44f1f8f6a893cc01984b025e0bcb067e3200df9 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/a4bc5ab364837d749e7891c9013fdc3b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bd30564d9d3f5cf8d440ff0c30aaa6ddd46b02cf9d2fe9a7560696a26b2c6b23 +size 4492 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/aad64aba60ad60b78757aa42d49a13f5_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/aad64aba60ad60b78757aa42d49a13f5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..66b778a1d97787137c9ce2ccc6ff14fc5ba48ba2 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/aad64aba60ad60b78757aa42d49a13f5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7c53e7709187cbf3516a3c9c28c43a5dc9c045fd9375ee4ed9c41a7df28252ee +size 4479 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/c177bbe00e21bfeb50bb9dee1b423a7a_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/c177bbe00e21bfeb50bb9dee1b423a7a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..117a0d2a78de3eb76d0eaf9e4ab834455727248c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/c177bbe00e21bfeb50bb9dee1b423a7a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:21b04990c2990d3c0a00c3e65128b8b6c61853765b5d9af2f6e14d93a02fb51e +size 4538 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/c2956eb1fa527be7b55bccb815ac9ce4_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/c2956eb1fa527be7b55bccb815ac9ce4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..401d2488743aad4ffbb00b9fc22f6ce3c8c0a911 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/c2956eb1fa527be7b55bccb815ac9ce4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5e029f3f81fd6984aae8f60e1c4cf957cf4d8e09fa48da075e1dbd829b76fe24 +size 4538 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/defa3d63bf1a918b413d688342d6fe16_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/defa3d63bf1a918b413d688342d6fe16_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a4dda2fb0f69a142650a3173b1980e8e3a4e2da6 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/defa3d63bf1a918b413d688342d6fe16_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c8cde75b63dd46c165cebd0b10708aa5e2e7fea547508428cb392cd017fd2dba +size 4523 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/e6fe1c644cf14ec4e42b2b65d258a8f8_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/e6fe1c644cf14ec4e42b2b65d258a8f8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..44b859fc9c43875462430b69aea0f23aa0258da5 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/e6fe1c644cf14ec4e42b2b65d258a8f8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9352d5f4e96e65778b11d7ff3893293b7a02a063b3fc21879c00cba77ed0668f +size 4610 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7423b16589e846f2b16ec9a44a377d2efd9a9090 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b000e2a5c716ba0590040bc3dc3321438d999e8b057249129751dff05131f8c +size 4564 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/fe65b3c38b53b1b30d5ab66570e74255_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/fe65b3c38b53b1b30d5ab66570e74255_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..15d0fad5c0881da83498505400285cca2823b8e3 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/fe65b3c38b53b1b30d5ab66570e74255_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:63eee7b30f2daf18f5bb065ae22ee9c5d51d00c72c753ea0931fa0eda48e18fd +size 4562 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/raw.md b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..d2ed87551bf08e250430af70862d6e4f14152222 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00/raw.md @@ -0,0 +1,2144 @@ + + +# --- **O-RAN Work Group 3 Near-Real-time RAN Intelligent Controller E2 Service Model (E2SM) KPM** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|----------------------------------------------------------------------------------------------|----| +| Foreword..... | 4 | +| Modal verbs terminology..... | 4 | +| 1 Scope..... | 4 | +| 2 References..... | 4 | +| 2.1 Normative references..... | 4 | +| 2.2 Informative references..... | 5 | +| 3 Definition of terms, symbols and abbreviations..... | 6 | +| 3.1 Terms..... | 6 | +| 3.2 Symbols..... | 6 | +| 3.3 Abbreviations..... | 6 | +| 4 General..... | 6 | +| 4.1 Forwards and Backwards Compatibility..... | 6 | +| 4.2 Specification Notations..... | 7 | +| 4.3 Void..... | 7 | +| 5 E2SM Services..... | 7 | +| 6 RAN Function Service Model Description..... | 8 | +| 6.1 RAN Function Overview..... | 8 | +| 6.2 Supported RIC Services..... | 8 | +| 6.2.1 REPORT..... | 8 | +| 7 RAN Function Description..... | 8 | +| 7.1 Description..... | 8 | +| 7.2 RAN Function Name..... | 9 | +| 7.3 Supported RIC Event Trigger Styles..... | 9 | +| 7.3.1 Event Trigger Style Types..... | 9 | +| 7.3.2 Event Trigger Style 1: Periodic Report..... | 9 | +| 7.4 Supported RIC REPORT Service Styles..... | 9 | +| 7.4.1 REPORT Service Style Type..... | 9 | +| 7.4.2 REPORT Service Style 1: E2 Node Measurement..... | 10 | +| 7.4.3 REPORT Service Style 2: E2 Node Measurement for a single UE..... | 11 | +| 7.4.4 REPORT Service Style 3: Condition-based, UE-level E2 Node Measurement..... | 11 | +| 7.4.5 REPORT Service Style 4: Common condition-based, UE-level Measurement..... | 12 | +| 7.4.6 REPORT Service Style 5: E2 Node Measurement for Multiple UEs..... | 13 | +| 7.4.7 REPORT Service Style 255: Multiple report Measurements..... | 13 | +| 7.5 Supported RIC INSERT Service Styles..... | 15 | +| 7.6 Supported RIC CONTROL Service Styles..... | 15 | +| 7.7 Supported RIC POLICY Service Styles..... | 15 | +| 7.7A Supported RIC QUERY Service Styles..... | 15 | +| 7.8 Supported RIC Styles and E2SM IE Formats..... | 15 | +| 7.9 Conversion of measurements derived from 3GPP defined measured values..... | 16 | +| 7.9.0 Conversion of measurement definitions..... | 16 | +| 7.9.1 Changes in the units of measurements while adopting for E2SM-KPM..... | 17 | +| 7.10 O-RAN specific Performance Measurement..... | 19 | +| 7.10.1 DL Transmitted Data Volume (RLC SDU)..... | 19 | +| 7.10.2 UL Transmitted Data Volume (RLC SDU)..... | 20 | +| 7.10.3 Distribution of Percentage of DL Transmitted Data Volume to Incoming Data Volume..... | 21 | +| 7.10.4 Distribution of Percentage of UL Transmitted Data Volume to Incoming Data Volume..... | 22 | +| 7.10.5 Distribution of DL Packet Drop Rate..... | 23 | +| 7.10.6 Distribution of UL Packet Loss Rate..... | 24 | +| 7.10.7 DL Synchronization Signal based Reference Signal Received Power (SS-RSRP)..... | 25 | +| 7.10.8 DL Synchronization Signal based Signal to Noise and Interference Ratio (SS-SINR)..... | 26 | +| 7.10.9 UL Sounding Reference Signal based Reference Signal Received Power (SRS-RSRP)..... | 27 | + +| | | | +|---------|-------------------------------------------------------------------|----| +| 7.10.10 | Total number of scheduled time slots ..... | 28 | +| 7.10.11 | DL Transmitted Data Volume (MAC SDU) ..... | 33 | +| 7.10.12 | UL Transmitted Data Volume (MAC SDU) ..... | 34 | +| 8 | Elements for E2SM Service Model ..... | 34 | +| 8.1 | General ..... | 34 | +| 8.2 | Message Functional Definition and Content ..... | 35 | +| 8.2.1 | Messages for RIC Functional procedures ..... | 35 | +| 8.2.2 | Messages for RIC Global Procedures ..... | 47 | +| 8.3 | Information Element definitions ..... | 49 | +| 8.3.1 | General ..... | 49 | +| 8.3.2 | RAN Function Name ..... | 49 | +| 8.3.3 | RIC Style Type ..... | 49 | +| 8.3.4 | RIC Style Name ..... | 49 | +| 8.3.5 | RIC Format Type ..... | 49 | +| 8.3.6 | Void ..... | 49 | +| 8.3.7 | Void ..... | 49 | +| 8.3.8 | Granularity Period ..... | 49 | +| 8.3.9 | Measurement Type Name ..... | 50 | +| 8.3.10 | Measurement Type ID ..... | 50 | +| 8.3.11 | Measurement Label ..... | 50 | +| 8.3.12 | Time Stamp ..... | 52 | +| 8.3.13 | Void ..... | 53 | +| 8.3.14 | S-NSSAI ..... | 53 | +| 8.3.15 | PLMN Identity ..... | 53 | +| 8.3.16 | Void ..... | 53 | +| 8.3.17 | 5QI ..... | 53 | +| 8.3.18 | QCI ..... | 53 | +| 8.3.19 | Void ..... | 53 | +| 8.3.20 | Cell Global ID ..... | 53 | +| 8.3.21 | QFI ..... | 53 | +| 8.3.22 | Test Condition Information ..... | 53 | +| 8.3.23 | Test Condition Value ..... | 55 | +| 8.3.24 | UE ID ..... | 55 | +| 8.3.25 | Logical OR ..... | 55 | +| 8.3.26 | Bin Range Definition ..... | 56 | +| 8.3.27 | Bin Range Value ..... | 56 | +| 8.3.28 | Measured Value Reporting Condition ..... | 56 | +| 8.3.29 | Beam ID ..... | 57 | +| 8.3.30 | Job ID ..... | 57 | +| 8.4 | Information Element Abstract Syntax (with ASN.1) ..... | 58 | +| 8.4.1 | General ..... | 58 | +| 8.4.2 | Information Element definitions ..... | 58 | +| 9 | Handling of Unknown, Unforeseen and Erroneous Protocol Data ..... | 70 | +| | Annex (informative): ..... | 71 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG3 of the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the E2 Service Model (E2SM) "Key Performance Measurement" (KPM) for the RAN function handling reporting of the cell-level performance measurements for 5G networks defined in TS 28.552 [4] and for EPC networks defined in TS 32.425 [8], and their possible adaptation of UE-level or QoS flow-level measurements. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +- NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. +- NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +The following referenced documents are necessary for the application of the present document. + +- [1] Void +- [2] O-RAN-WG3.TS.E2GAP: “O-RAN E2 General Aspects and Principles”. +- [3] O-RAN.WG3.TS.E2AP, "O-RAN E2 Application Protocol (E2AP) " +- [4] 3GPP TS 28.552: "Management and orchestration 5G performance measurements". +- [5] ITU-T Recommendation X.680 (2002-07): "Information technology – Abstract Syntax Notation One (ASN.1): Specification of basic notation". +- [6] ITU-T Recommendation X.681 (2002-07): "Information technology – Abstract Syntax Notation One (ASN.1): Information object specification". +- [7] ITU-T Recommendation X.691 (2002-07): "Information technology - ASN.1 encoding rules - Specification of Packed Encoding Rules (PER)". +- [8] 3GPP TS 32.425: "Telecommunication management Performance Management Performance managements". +- [9] IETF RFC 5905 (2010-06): "Network Time Protocol Version 4: Protocol and Algorithms Specification". +- [10] 3GPP TS 32.404: “Telecommunication management; Performance Management (PM); Performance measurements; Definitions and template”. +- [11] Void +- [12] O-RAN-WG3.TS.E2SM: “O-RAN E2 Service Model (E2SM)”. +- [13] 3GPP TS 36.413: “E-UTRAN; S1 Application Protocol (S1AP)” +- [14] 3GPP TS 23.501: "System architecture for the 5G System (5GS); Stage 2" +- [15] 3GPP TS 36.214: "E-UTRA; Physical layer; Measurements" +- [16] 3GPP TS 38.215: "NR; Physical layer measurements" +- [17] 3GPP TS 38.133: "NR; Requirements for support of radio resource management" +- [18] 3GPP TS 38.214: "NR; Physical layer procedures for data" +- [19] 3GPP TS 23.203: "Policy and charging control architecture" +- [20] 3GPP TS 23.003: "Numbering, addressing and identification" +- [21] O-RAN.WG3.TS.UCR: “O-RAN Use Cases and Requirements” +- [22] Void +- [23] O-RAN.WG1.OAD: “O-RAN Architecture Description” +- [24] Void +- [25] 3GPP TS 37.340: "NR; Multi-connectivity; Overall description; Stage-2". + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +[i.1] O-RAN.WG1.mMIMO: “O-RAN Massive MIMO Use Cases Technical Report” + +[i.2] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications” + +[i.3] 3GPP TR 25.921: “Guidelines and principles for protocol description and error handling”. + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in TR 21.905 [i.2], O-RAN WG1.OAD [23], O-RAN.WG3.TS.E2SM [12] and the following apply: + +**KPM Report:** Key performance measurements for 4G LTE and 5G NR Network Functions. + +## 3.2 Symbols + +Void. + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 错误!未找到引用源。 , O-RAN WG1.OAD [23] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 错误!未找到引用源。 and O-RAN WG1.OAD [23]. + +| | | +|-------|-------------------------------| +| EN-DC | E-UTRA-NR Dual Connectivity | +| MR-DC | Multi-Radio Dual Connectivity | + +# --- 4 General + +## 4.1 Forwards and Backwards Compatibility + +The forwards and backwards compatibility of the protocol is assured by a mechanism where all current and future messages, and IEs or groups of related IEs, include ID and criticality fields that are coded in a standard format that will not be changed in the future. These parts can always be decoded regardless of the standard version. + +## 4.2 Specification Notations + +For the purposes of the present document, the following notations apply: + +| | | +|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Service | When referring to a Service in the present document the <b>SERVICE NAME</b> is written with upper case characters and in bold followed by the word "service", e.g. <b>REPORT</b> service. | +| Procedure | When referring to an elementary procedure in the present document the Procedure Name is written with the first letters in each word in upper case characters followed by the word "procedure", e.g. Handover Preparation procedure. | +| Message | When referring to a message in the present document the MESSAGE NAME is written with all letters in upper case characters followed by the word "message", e.g. HANDOVER REQUEST message. | +| IE | When referring to an information element (IE) in the present document the <i>Information Element Name</i> is written with the first letters in each word in upper case characters and all letters in Italic font followed by the abbreviation "IE", e.g. <i>E-RAB ID</i> IE. | +| Value of an IE | When referring to the value of an information element (IE) the present document the "Value" is written as it is specified in the present document enclosed by quotation marks, e.g. "Value". | + +## 4.3 Void + +# 5 E2SM Services + +As defined in E2 General Aspects and Principles [2], a given RAN Function offers a set of services to be exposed over the E2 (**REPORT**, **INSERT**, **CONTROL**, **POLICY** and/or **QUERY**) using E2AP [3] defined procedures. Each of the E2AP Procedures listed in table 5-1 contains specific E2 Node RAN Function dependent Information Elements (IEs). + +**Table 5-1: Relationship between E2SM services and E2AP Information elements** + +| RAN Function specific E2AP Information Elements | E2AP Information Element reference | Related E2AP Procedures | +|-------------------------------------------------|------------------------------------|--------------------------------| +| <i>RIC Event Trigger Definition</i> IE | E2AP [3] clause 9.2.9 | RIC Subscription | +| <i>RIC Action Definition</i> IE | E2AP [3] clause 9.2.12 | RIC Subscription | +| <i>RIC Indication Header</i> IE | E2AP [3] clause 9.2.17 | RIC Indication | +| <i>RIC Indication Message</i> IE | E2AP [3] clause 9.2.16 | RIC Indication | +| <i>RIC Call Process ID</i> IE | E2AP [3] clause 9.2.18 | RIC Indication<br>RIC Control | +| <i>RIC Control Header</i> IE | E2AP [3] clause 9.2.20 | RIC Control | +| <i>RIC Control Message</i> IE | E2AP [3] clause 9.2.19 | RIC Control | +| <i>RIC Control Outcome</i> IE | E2AP [3] clause 9.2.25 | RIC Control | +| <i>RAN Function Definition</i> IE | E2AP [3] clause 9.2.23 | E2 Setup<br>RIC Service Update | +| <i>RIC Query Header</i> IE | E2AP [3] clause 9.2.36 | RIC Query | +| <i>RIC Query Definition</i> IE | E2AP [3] clause 9.2.37 | RIC Query | +| <i>RIC Query Outcome</i> IE | E2AP [3] clause 9.2.38 | RIC Query | + +All of these RAN Function specific IEs are defined in E2AP [3] as "OCTET STRING". + +The purpose of this specification is to define the contents of these fields for the specific RAN Function "KPM Monitor". + +# --- 6 RAN Function Service Model Description + +## 6.1 RAN Function Overview + +E2 Service Model KPM (E2SM-KPM) shall support O-CU-CP, O-CU-UP, and O-DU as part of NG-RAN connected to 5GC or as part of E-UTRAN connected to EPC. + +The E2 Node shall host the RAN Function “KPM Monitor” which performs the following functionalities: + +- Exposure of available measurements from O-DU, O-CU-CP, and/or O-CU-UP via the RAN Function Definition IE. +- Periodic reporting of measurements subscribed from Near-RT RIC. + +This E2SM specification also exposes a set of services described in clause 6.2. + +## 6.2 Supported RIC Services + +### 6.2.1 REPORT + +The “KPM Monitor” RAN Function shall provide the following **REPORT** services: + +a) Fundamental level services: + +- E2 Node Measurement +- E2 Node Measurement for a single UE +- Condition-based, UE-level E2 Node Measurement +- Common Condition-based, UE-level E2 Node Measurement +- E2 Node Measurements for multiple UEs + +b) Integrated level services: + +- Multi-report + +These services shall be initiated according to: + +- Periodical event. + +# --- 7 RAN Function Description + +## 7.1 Description + +The E2AP [3] procedures, E2 SETUP and RIC SERVICE UPDATE, are used to transport the RAN Function Definition IE. + +For a specific RAN Function declared using E2SM-KPM, the RAN Function Definition IE, defined in clause 8.2.2, shall report the following information: + +- RAN Function name along with associated information on E2SM definition +- Event trigger styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC REPORT Service styles list along with the corresponding encoding type for each associated E2AP IE. + +For the case where *RAN Function Definition* IE, defined in clause 8.2.2, is present in the E2 SETUP REQUEST message the IE shall provide a complete list of all Styles and associated Formats and, where appropriate, Measurement information for all supported RIC services reflecting the current status of the RAN Function. + +For the case where *RAN Function Definition* IE, defined in clause 8.2.2, is present in the RIC SERVICE UPDATE message within the E2AP *RAN Functions Added List* IE, the IE shall provide a complete list of all Styles and associated Formats and, where appropriate, Measurement information for all supported RIC services for the newly added RAN Function with a new RAN Function ID. + +For the case where *RAN Function Definition* IE, defined in clause 8.2.2, is present in the RIC SERVICE UPDATE message within the E2AP *RAN Functions Modified List* IE, the IE shall provide a complete list of all the Styles and associated Formats and, where appropriate, Measurement information for all supported RIC services including both modified and unchanged information for an existing RAN Function. + +## 7.2 RAN Function Name + +RAN Function Short Name “ORAN-E2SM-KPM” + +RAN Function Description “KPM Monitor” + +RAN Function Instance, required when and if an E2 Node exposes more than one instance of a RAN Function based on this E2SM. + +## 7.3 Supported RIC Event Trigger Styles + +### 7.3.1 Event Trigger Style Types + +| RIC Style Type | Style Name | Supported RIC Service Style | | | Style Description | +|----------------|-----------------|-----------------------------|--------|--------|------------------------------------------------------------------| +| | | Report | Insert | Policy | | +| 1 | Periodic Report | 1 | - | - | <i>RIC Event Trigger Definition</i> IE based on reporting period | + +### 7.3.2 Event Trigger Style 1: Periodic Report + +Event Trigger style 1 shall set the KPM report period and uses the *RIC Event Trigger Definition* IE Format 1 (see clause 8.2.1.1.1) + +## 7.4 Supported RIC REPORT Service Styles + +### 7.4.1 REPORT Service Style Type + +| RIC Style Type | Style Name | Style Type Description | +|----------------|-----------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | E2 Node Measurement | Used to carry measurement report from a target E2 Node<br>Belongs to Fundamental level REPORT Services | +| 2 | E2 Node Measurement for a single UE | Used to carry measurement report for a single UE of interest from a target E2 Node<br>Belongs to Fundamental level REPORT Services | +| 3 | Condition-based, UE-level E2 Node Measurement | Used to carry UE-level measurement report for a group of UEs per measurement type matching subscribed conditions from a target E2 Node<br>Belongs to Fundamental level REPORT Services | + +| | | | +|-----|----------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 4 | Common Condition-based, UE-level Measurement | Used to carry measurement report for a group of UEs across a set of measurement types satisfying common subscribed conditions from a target E2 Node<br>Belongs to Fundamental level REPORT Services | +| 5 | E2 Node Measurement for multiple UEs | Used to carry measurement report for multiple UEs of interest from a target E2 Node<br>Belongs to Fundamental level REPORT Services | +| 255 | Multiple report measurements | Used for multiple actions of the selected fundamental level REPORT Service style(s).<br>Belongs to Integrated level REPORT Services. | + +The Report Service style 255 supports integrated level services configured per *RIC Action Definition* message by reusing the report *RIC Action Definition* IE and *RIC Indication Message* IE messages defined in the selected fundamental level Report Service style(s). + +### 7.4.2 REPORT Service Style 1: E2 Node Measurement + +#### 7.4.2.1 REPORT Service Style description + +REPORT Service style 1 provides the performance measurement information collection from an E2 Node. + +#### 7.4.2.2 REPORT Service *RIC Action Definition* IE contents + +REPORT Service style 1 aims to subscribe to the measurements defined in TS 28.552 [4] and TS 32.425 [8], and shall use the *RIC Action Definition* IE Format 1 (see clause 8.2.1.2.1). + +REPORT Service *RIC Action Definition* IE Format 1 contains measurement types that Near-RT RIC is requesting to subscribe followed by a list of subcounters to be measured for each measurement type, and a granularity period indicating collection interval of those measurements. For a certain measurement type to be subscribed, the *Matching Condition for Reporting* IE may also be included to give conditions for the E2 Node in reporting measurements, to report a measured value corresponding to that measurement type only when the value satisfies the given conditions. + +For the measurement types that belong to a measurement object class confined in a single cell (e.g. "EUTranCellFDD" in TS 32.425 [8] or "NRCellIDU" in TS 28.552 [4]), the *Cell Global ID* IE shall be included in the IE to point to a specific cell for collecting measurements within the E2 Node. The *Cell Global ID* IE shall not be included if all the subscribed measurement types are cell agnostic, i.e. belonging to measurement object classes not confined in a single cell (e.g. "GNBCUUPFunction" in TS 28.552 [4]). In case that both single-cell-confined and cell agnostic measurement types are subscribed together, the *Cell Global ID* IE shall be included in the IE and the E2 Node shall ignore the included *Cell Global ID* IE for those cell agnostic measurement types. + +A measurement ID can be used for subscription instead of a measurement type if an identifier of a certain measurement type was exposed by an E2 Node via the *RAN Function Definition* IE. + +#### 7.4.2.3 REPORT Service *RIC Indication Header* IE contents + +REPORT Service style 1 shall use the *RIC Indication Header* IE Format 1 (see clause 8.2.1.3.1), which contains a measurement collection start time as UTC format. + +REPORT Service *RIC Indication Header* IE Format 1 may carry file format version, sender name, sender type, and vendor name as printable strings. + +#### 7.4.2.4 REPORT Service *RIC Indication Message* IE contents + +REPORT Service style 1 shall use the *RIC Indication Message* IE Format 1 (see clause 8.2.1.4.1). + +REPORT Service *RIC Indication Message* IE Format 1 carries a set of measurement data reported from an E2 Node. The reported data contains a set of measurement records, each collected at every granularity period during the reporting period. In case that the *Matching Condition for Reporting* IE has been configured in the *RIC Action Definition* IE for a measurement type and a measured value corresponding to that measurement type in a granularity period did not satisfy the configured reporting + +condition, the E2 Node shall indicate “Not Satisfied” instead of reporting the actual measured value within the measurement record corresponding to that granularity period. In case the configured reporting condition(s) are not satisfied entirely for a reporting period for all the subscribed measurement types, the E2 Node may omit sending the report for this reporting period. In case the E2 Node is not able to provide reliable data for a granularity period during the reporting period, it may include the optional *Incomplete Flag* IE, which indicates that the corresponding measurements record in the reported data is not reliable. + +REPORT Service *RIC Indication Message* IE Format 1 may carry subscription information, i.e. *Measurement Information List* IE that indicates the order of measured values for each measurement record in the reported data, or their granularity period. If not present, the original subscription information shall apply. + +### 7.4.3 REPORT Service Style 2: E2 Node Measurement for a single UE + +#### 7.4.3.1 REPORT Service Style description + +REPORT Service style 2 provides the performance measurement information collection for a single UE of interest from an E2 Node. + +#### 7.4.3.2 REPORT Service *RIC Action Definition* IE contents + +REPORT Service style 2 shall use the *RIC Action Definition* IE Format 2 (see clause 8.2.1.2.2), where the included UE ID indicates a specific UE of interest for measurement collection. + +The rest of the subscription information follows the same as described in 7.4.2.2. + +#### 7.4.3.3 REPORT Service *RIC Indication Header* IE contents + +REPORT Service style 2 shall use the *RIC Indication Header* IE Format 1 (see clause 8.2.1.3.1) as described in 7.4.2.3. + +#### 7.4.3.4 REPORT Service *RIC Indication Message* IE contents + +REPORT Service style 2 shall use the *RIC Indication Message* IE Format 1 (see clause 8.2.1.4.1) as described in 7.4.2.4, where the measurement data reported is associated only to a specific UE that was subscribed. + +### 7.4.4 REPORT Service Style 3: Condition-based, UE-level E2 Node Measurement + +#### 7.4.4.1 REPORT Service Style description + +REPORT Service style 3 provides the UE-level performance measurement information collection for a group of UEs per measurement type matching subscribed conditions from an E2 Node. + +#### 7.4.4.2 REPORT Service *RIC Action Definition* IE contents + +REPORT Service style 3 shall use the *RIC Action Definition* IE Format 3 (see clause 8.2.1.2.3), where, for each requested measurement within the *Measurement Information Condition List* IE, the *Matching Condition* IE serves as a condition to include the matched UEs’ measurement values into the reporting. The *Matching Condition* IE can be expressed by a list of subcounters to be measured (i.e. as a list of labels), or by a list of test conditions that need to be passed, or by a combination of both. + +The rest of the subscription information follows the same as described in 7.4.2.2. + +#### 7.4.4.3 REPORT Service *RIC Indication Header* IE contents + +REPORT Service style 3 shall use the *RIC Indication Header* IE Format 1 (see clause 8.2.1.3.1) as described in 7.4.2.3. + +#### 7.4.4.4 REPORT Service RIC Indication Message IE contents + +REPORT Service style 3 shall use the *RIC Indication Message IE* Format 2 (see clause 8.2.1.4.2). + +REPORT Service *RIC Indication Message IE* Format 2 carries a set of UE-level measurement data matching subscribed conditions. The included *Measurement Information Condition UE List IE* indicates the order of measured values for each measurement record in the reported data – a list of all the UE ID(s) satisfying the subscribed *Matching Condition IE* for each requested measurement within a Reporting Period. + +In every granularity period during which a UE matching a subscribed condition stays in the E2 Node and maintains the RRC\_CONNECTED or RRC\_INACTIVE state, the E2 Node shall collect the related data and reports it at the end of the reporting period. + +The *List of matched UE IDs IE* for a certain measurement type in the *Measurement Information Condition UE List IE* indicates all the UE ID(s) that satisfied the subscribed *Matching Condition IE* for that measurement type and maintained the RRC\_CONNECTED or RRC\_INACTIVE state at least for one granularity period during the reporting period. The *List of matched UE IDs IE* can be omitted for a certain subscribed measurement type if none of the UEs were matched during the reporting period. If the *List of matched UE IDs IE* is used for a measurement type, then the same IE shall be used for all the measurement types in the *Measurement Information Condition UE List IE*. + +If the *List of matched UE IDs IE* is used, in the granularity periods where the UE does not appear in the RRC\_CONNECTED or RRC\_INACTIVE state (e.g. transitioned to RRC\_IDLE or UE identity track is lost), the E2 Node shall not collect the related data and NULL shall be reported for those granularity periods until the end of the Reporting Period. In this case, the E2 Node shall stop reporting measurements related to this UE in the subsequent reporting periods. If the *List of matched UE IDs IE* is used and a UE whose ID is included in the IE appeared in the middle of the reporting period, then NULL shall be reported for the granularity periods prior to the UE appearing in the E2 Node. + +On the other hand, the *Sequence of Matched UE IDs for Granularity Periods IE* for a certain measurement type in the *Measurement Information Condition UE List IE* can be used to indicate the UE ID(s) that satisfied the subscribed *Matching Condition IE* for the corresponding measurement type and maintained the RRC\_CONNECTED or RRC\_INACTIVE state, separately for each and every granularity period in chronological order. If the *Sequence of Matched UE IDs for Granularity Periods IE* is used for a measurement type, then the same IE shall be used for all the measurement types in the *Measurement Information Condition UE List IE*, and the *List of matched UE IDs IE*, if included for any measurement type, shall be ignored. + +The rest of the information follows the same as described in 7.4.2.4. + +### 7.4.5 REPORT Service Style 4: Common condition-based, UE-level Measurement + +#### 7.4.5.1 REPORT Service Style description + +REPORT Service style 4 provides the UE-level performance measurement information collection for a group of UEs across a set of measurement types matching common subscribed conditions from an E2 Node. + +#### 7.4.5.2 REPORT Service RIC Action Definition IE contents + +REPORT Service style 4 shall use the *RIC Action Definition IE* Format 4 (see clause 8.2.1.2.4), where a *Matching Condition IE* serves as a condition to include the matched UEs' measurement values into the reporting, common for each requested measurement within the *Measurement Information List IE*. The *Matching Condition IE* is expressed by a list of test conditions to filter matching UEs. + +The rest of the subscription information follows the same as described in 7.4.2.2. + +#### 7.4.5.3 REPORT Service RIC Indication Header IE contents + +REPORT Service style 4 shall use the *RIC Indication Header IE* Format 1 (see clause 8.2.1.3.1) as described in 7.4.2.3. + +#### 7.4.5.4 REPORT Service *RIC Indication Message* IE contents + +REPORT Service style 4 shall use the *RIC Indication Message* IE Format 3 (see clause 8.2.1.4.3). + +REPORT Service *RIC Indication Message* IE Format 3 carries a list of measurement data for UE(s) matching subscribed conditions. + +In every granularity period during which a UE matching a subscribed condition stays in the E2 Node and maintains the RRC\_CONNECTED or RRC\_INACTIVE state, the E2 Node shall collect the related data and report it at the end of the reporting period. In the granularity periods where the UE does not appear in the RRC\_CONNECTED or RRC\_INACTIVE state (e.g. transitioned to RRC\_IDLE or UE identity track is lost), the E2 Node shall not collect the related data and NULL shall be reported for those granularity periods until the end of the Reporting Period. In this case, the E2 Node shall stop reporting measurements related to this UE in the subsequent reporting periods. + +If none of the UEs were matched during the reporting period, then E2 Node shall not report measurements for that reporting period. + +The rest of the information follows the same as described in 7.4.2.4. + +### 7.4.6 REPORT Service Style 5: E2 Node Measurement for Multiple UEs + +#### 7.4.6.1 REPORT Service Style description + +REPORT Service style 5 provides the performance measurement information collection for multiple UEs of interest from an E2 Node. + +#### 7.4.6.2 REPORT Service *RIC Action Definition* IE contents + +REPORT Service style 5 shall use the *RIC Action Definition* IE Format 5 (see clause 8.2.1.2.5), where the included UE Identifiers indicates UEs of interest for measurement collection. + +The rest of the subscription information follows the same as described in 7.4.2.2. + +#### 7.4.6.3 REPORT Service *RIC Indication Header* IE contents + +REPORT Service style 5 shall use the *RIC Indication Header* IE Format 1 (see clause 8.2.1.3.1) as described in 7.4.2.3. + +#### 7.4.6.4 REPORT Service *RIC Indication Message* IE contents + +REPORT Service style 5 shall use the *RIC Indication Message* IE Format 3 (see clause 8.2.1.4.3) as described in 7.4.5.4, where the measurement data reported is associated to multiple UEs that was subscribed and available in the system. + +### 7.4.7 REPORT Service Style 255: Multiple report measurements + +#### 7.4.7.1 REPORT Service Style description + +REPORT Service style 255 provides support for the integration of multiple report jobs into a single report action from an E2 Node. + +This REPORT Service style provides a mechanism to initiate multiple report action jobs of the selected fundamental level REPORT Service style(s) that should be processed in an integrated manner by the E2 Node, i.e. the RIC Subscription procedure is considered failed if at least one of the indicated report actions is unsuccessfully subscribed, and RIC SUBSCRIPTION FAILURE message shall be sent containing the appropriate error cause. + +The resulting measurement reports may be either transmitted as an integrated single Report message consisting of a list of individual job specific Report messages or as individual Report messages each corresponding to a single job in the list defined in the *RIC Action Definition* IE. + +#### 7.4.7.2 REPORT Service *RIC Action Definition* IE contents + +**REPORT** style 255 shall use *E2SM-KPM Action Definition Format 255* IE (see clause 8.2.1.2.6). + +This REPORT Service style aims to support the subscription of a set of report jobs, each defined by either a corresponding *Job Specific Action Definition* IE or by a *Common Action Definition* IE along with optional IEs used to introduce per job specific values (i.e. to set a different cell ID for each job), into an integrated *RIC Action Definition* IE (see clause 8.2.1.2). + +The REPORT Service *RIC Action Definition* IE contains the list of jobs, each with a unique *Job ID* IE and either: + +- a job specific fundamental level REPORT Service specific *RIC Action Definition* IE +- one or more optional job specific modification IEs (*Job Specific Cell Global ID* IE, *Job Specific UE ID* IE, *Job Specific List of Subscribed UE IDs* IE) that are used to replace specific IEs within the *Common Action Definition* IE. + +The following table presents the applicable report styles, E2SM-KPM Action Definition Format and IE for each Job Specific IE + +| Job specific IE | Applicable Fundamental level Report Style | E2SM-KPM Action Definition Format | Applicable IE | +|--------------------------------------------------|-------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------|-------------------------------------| +| <i>Job Specific Cell Global ID</i> IE | 1 | E2SM-KPM Action Definition Format 1 | <i>Cell Global ID</i> IE | +| | 2 | E2SM-KPM Action Definition Format 1, contained within <i>Subscription Information</i> IE in E2SM-KPM Action Definition Format 2 | <i>Cell Global ID</i> IE | +| | 3 | E2SM-KPM Action Definition Format 3 | <i>Cell Global ID</i> IE | +| | 4 | E2SM-KPM Action Definition Format 1, contained within <i>Subscription Information</i> IE in E2SM-KPM Action Definition Format 4 | <i>Cell Global ID</i> IE | +| | 5 | E2SM-KPM Action Definition Format 1, contained within <i>Subscription Information</i> IE in E2SM-KPM Action Definition Format 5 | <i>Cell Global ID</i> IE | +| <i>Job Specific UE ID</i> IE | 2 | E2SM-KPM Action Definition Format 2 | <i>UE ID</i> IE | +| <i>Job Specific List of Subscribed UE IDs</i> IE | 5 | E2SM-KPM Action Definition Format 5 | <i>List of Subscribed UE IDs</i> IE | + +REPORT Service *RIC Action Definition 255* IE also contains a common *Reporting Approach* IE used to indicate if the resulting RIC Indication message shall be used to carry an integrated report or if each job is to be reported independently resulting in multiple RIC Indication messages sent at each event trigger. + +Example *RIC Action Definition* IE may contain the optional *Common Action Definition* IE corresponding to a common fundamental level REPORT Service specific *RIC Action Definition* IE using E2SM-KPM Action Definition Format 1 to initiate a REPORT Style 1 and each job in the list of jobs may contain a *Job Specific Cell Global ID* IE. In this case each job shall be initiated according to the common with the exception that each job applies to different Cell Global ID provided by *Job Specific Cell Global ID* IE. At each Event Trigger, the *Reporting Approach* IE is used to determine if the measurements shall be reported either as a single RIC Indication message containing a list of job specific Measurement Reports (one per request cell), each using E2SM-KPM Indication Message Format 1, or as a set of RIC Indication messages each containing the Measurement Report for a single requested cell. + +#### 7.4.7.3 REPORT Service *RIC Indication Header* IE contents + +REPORT Service style 255 shall use the *RIC Indication Header* IE Format 1 (see clause 8.2.1.3.1) as described in 7.4.2.3. + +#### 7.4.7.4 REPORT Service *RIC Indication Message* IE contents + +REPORT Service style 255 shall use either the *E2SM-KPM Indication Message* IE Format 255 (see clause 8.2.1.4.4) or individual *RIC Indication Message* IE for each job in the list provided in the *E2SM-KPM Action Definition Format 255* IE (see + +clause 8.2.1.2.6). The appropriate approach is indicated by the *Reporting Approach* IE contained in the *E2SM-KPM Action Definition Format 255* IE (see clause 8.2.1.2.6). + +For the case where *E2SM-KPM Indication Message* IE Format 255 (see clause 8.2.1.4.4) is to be sent, the message carries a sequence of *RIC Indication Message* IE carrying the reports formatted according to the fundamental level REPORT Service specific *RIC Indication Message* IEs each associated with a *Job ID* IE. + +For the case where individual RIC Indication messages are to be sent, the option *Job ID* IE shall be used in the *RIC Indication Message* IE to indicate which report in the list of jobs defined *E2SM-KPM Action Definition Format 255* IE (see clause 8.2.1.2.6) is being reported in each RIC Indication message. + +In all cases the individual measurements and measurement records are ordered according to the definition in the applicable fundamental level Report style. + +## 7.5 Supported RIC INSERT Service Styles + +Void + +## 7.6 Supported RIC CONTROL Service Styles + +Void. + +## 7.7 Supported RIC POLICY Service Styles + +Void. + +## 7.7A Supported RIC QUERY Service Styles + +Void. + +## 7.8 Supported RIC Styles and E2SM IE Formats + +Table 7.8-1 and 7.8-2 provide a summary of the E2SM IE Formats defined to support this E2SM specification. + +**Table 7.8-1: Summary of the E2SM IE Formats defined to support RIC Event Trigger Styles** + +| RIC Event<br>Trigger Style | Event Trigger<br>Definition Format | +|----------------------------|------------------------------------| +| Style 1 | 1 | +| | | + +Table 7.8-2: Summary of the E2SM IE Formats defined to support RIC Service Styles + +| RIC Service Style | Action Definition Format | Indication Header Format | Indication Message Format | Call Process ID Format | Control Header Format | Control Message Format | Control Outcome Format | +|-------------------|--------------------------|--------------------------|---------------------------|------------------------|-----------------------|------------------------|------------------------| +| <b>REPORT</b> | | | | | | | | +| Style 1 | 1 | 1 | 1 | | | | | +| Style 2 | 2 | 1 | 1 | | | | | +| Style 3 | 3 | 1 | 2 | | | | | +| Style 4 | 4 | 1 | 3 | | | | | +| Style 5 | 5 | 1 | 3 | | | | | +| Style 255 | 255 | 1 | 255 | | | | | +| | | | | | | | | +| <b>INSERT</b> | | | | | | | | +| | | | | | | | | +| <b>CONTROL</b> | | | | | | | | +| | | | | | | | | +| <b>POLICY</b> | | | | | | | | +| | | | | | | | | +| <b>QUERY</b> | | | | | | | | +| | | | | | | | | + +## 7.9 Conversion of measurements derived from 3GPP defined measured values + +## 7.9.0 Conversion of measurement definitions + +UE level and QoS Flow level measurements are defined based on the conversion of the measurements' definitions provided in TS 28.552 [4], TS 32.425 [8], and O-RAN specific measurement defined in clause 7.10 according to the following rules: + +| The type of the original measurements | The corresponding per-UE and per-UE-per-slice measurements | The corresponding per-QoS flow and per-slice-per-QoS flow measurements | Notes | +|-----------------------------------------------------------------|------------------------------------------------------------|------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Throughput<br>Delay<br>Data volume<br>In-session activity time | Measured per UE | Measured per QoS flow | For the Throughput and Data volume measurements, the formulas specified in 3GPP are used with restriction to the individual UE or individual QoS flow , and also based on clause 7.9.1. | +| PDCP drop rate<br>IP latency | Measured per UE | Measured per QoS flow | For the Throughput and Data volume measurements, the formulas specified in 3GPP are used with restriction to the individual UE or individual QoS flow. | +| Radio resource utilization | Measured per UE | N/A | The formulas specified in 3GPP are used with restriction to the individual UE. | +| RRC connections related<br>PDU sessions related<br>DRBs related | Measured per UE | N/A | | + +| | | | | +|----------------------------------------------------------|-----------------|-----|--| +| QoS flows related | | | | +| Mobility management | Measured per UE | N/A | | +| CQI related<br>MCS related | Measured per UE | N/A | | +| PEE related | N/A | N/A | | +| Distribution of<br>Normally/Abnormally<br>Released Calls | Measured per UE | N/A | | + +Beam level measurements are defined based on the conversion of the measurements' definitions provided in TS 28.552 [4], TS 32.425 [8], and O-RAN specific measurement defined in clause 7.10 according to the following rules: + +| The type of the original measurements | The corresponding per-beam measurements | Notes | +|---------------------------------------|----------------------------------------------------|----------------------------------------------------------------------------------------------------| +| Mobility Management | Measured per source beam and neighboring cell pair | The formulas specified in 3GPP are used with restriction to the source beam-neighboring cell pair. | + +### 7.9.1 Changes in the units of measurements while adopting for E2SM-KPM + +The units of the following measurements in TS 28.552 [4] and TS 32.425 [8] are replaced with newer units, as shown in the table below. + +| Measurement Type | Measurement Name | Data Type | Unit used in 3GPP | Unit used in E2SM-KPM | +|--------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------|-----------|-------------------|-----------------------| +| DL Cell PDCP SDU Data Volume, defined in TS 28.552 [4] clause 5.1.2.1.2.1. | DRB.PdcpSduVolumeDL_Filter | INTEGER | Mbit | Kbit | +| UL Cell PDCP SDU Data Volume, defined in TS 28.552 [4] clause 5.1.2.1.2.2. | DRB.PdcpSduVolumeUL_Filter | INTEGER | Mbit | Kbit | +| DL PDCP PDU Data Volume, defined in TS 28.552 [4] clause 5.1.3.6.1.1. | QosFlow.PdcpPduVolumeDL_Filter | INTEGER | Mbit | Kbit | +| UL PDCP PDU Data Volume, defined in TS 28.552 [4] clause 5.1.3.6.1.2. | QosFlow.PdcpPduVolumeUL_Filter | INTEGER | Mbit | Kbit | +| DL PDCP SDU Data Volume, defined in TS 28.552 [4] clause 5.1.3.6.2.1. | QosFlow.PdcpSduVolumeDI_Filter | INTEGER | Mbit | Kbit | +| UL PDCP SDU Data Volume, defined in TS 28.552 [4] clause 5.1.3.6.2.2. | QosFlow.PdcpSduVolumeUI_Filter | INTEGER | Mbit | Kbit | +| DL Cell PDCP SDU Data Volume on X2 interface, defined in TS 28.552 [4] clause 5.1.2.1.1.2. | DRB.PdcpSduVolumeX2DL_Filter | INTEGER | Mbit | Kbit | +| UL Cell PDCP SDU Data Volume on X2 interface, defined in TS 28.552 [4] clause 5.1.2.1.2.2. | DRB.PdcpSduVolumeX2UL_Filter | INTEGER | Mbit | Kbit | +| DL Cell PDCP SDU Data Volume on Xn interface, defined in TS 28.552 [4] clause 5.1.2.1.1.3. | DRB.PdcpSduVolumeXnDL_Filter | INTEGER | Mbit | Kbit | +| UL Cell PDCP PDU Data Volume on Xn interface, defined in TS 28.552 [4] clause 5.1.2.1.2.3. | DRB.PdcpSduVolumeXnUL_Filter | INTEGER | Mbit | Kbit | +| DL PDCP SDU Data Volume per interface, defined in TS 28.552 [4] clause 5.1.3.6.2.3. | DRB.F1uPdcpSduVolumeDI.QoS,<br>DRB.X2uPdcpSduVolumeDI.QoS,<br>DRB.XnuPdcpSduVolumeDI.QoS | INTEGER | Mbit | Kbit | +| UL PDCP SDU Data Volume per interface, defined in TS 28.552 [4] clause 5.1.3.6.2.4. | DRB.F1uPdcpSduVolumeUI.QoS,<br>DRB.X2uPdcpSduVolumeUI.QoS,<br>DRB.XnuPdcpSduVolumeUI.QoS | INTEGER | Mbit | Kbit | +| DL cell PDCP SDU Data Volume, defined in TS 32.425 [8] clause 4.4.7.1. | DRB.PdcpSduVolumeDI_Filter | INTEGER | Mbit | Kbit | +| UL cell PDCP SDU Data Volume, defined in TS 32.425 [8] clause 4.4.7.2. | DRB.PdcpSduVolumeUI_Filter | INTEGER | Mbit | Kbit | +| In-session activity time for UE, defined in TS 28.552 [4] clause 5.1.1.13.2.2. | QF.SessionTimeUE | INTEGER | s | ms | +| In-session activity time for DRB, defined in TS 28.552 [4] clause 5.1.1.10.4. | DRB.SessionTime.5QI,<br>DRB.SessionTime.SNSSAI | INTEGER | s | ms | +| In-session activity time for QoS flow, defined in TS 28.552 [4] clause 5.1.1.13.2.1. | QF.SessionTimeQoS.QoS | INTEGER | s | ms | +| In-session activity time for UE, defined in TS 32.425 [8] clause 4.2.4.1. | ERAB.SessionTimeUE | INTEGER | s | ms | +| In-session activity time for E-RABs, defined in TS 32.425 [8] clause 4.2.4.2. | ERAB.SessionTimeQCI.QCI | INTEGER | s | ms | +| IP throughput in UL, defined in TS 32.425 [8] clause 4.4.6.2. | DRB.IPThpUI.QCI | REAL | Kbit | Kbit/s | + +The changes in the units of the measurements shown in the above table are to prevent the reported values from being reported as 0 caused by rounding off the precision in the decimals to report them as INTEGER, except the last row of “IP throughput in UL”, which is to fix the erroneous unit. + +## 7.10 O-RAN specific Performance Measurement + +### 7.10.1 DL Transmitted Data Volume (RLC SDU) + +| Measurement Name | DL Transmitted Data Volume (RLC SDU) | +|-----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | <p>This measurement provides the transmitted data volume in the downlink in a measurement time. The measurement is split into subcounters per QoS level (mapped 5QI or QCI in EN-DC), and subcounters per supported S-NSSAI.</p> <p>The unit is kbit.</p> | +| b) Collection Method | CC | +| c) Condition | <p>This measurement is obtained by counting the data volume counted on RLC SDU level, in kbit successfully transmitted (acknowledged by UE) in DL for one DRB during measurement time T. Separate counters are maintained for each mapped 5QI (or QCI for option 3) and for each supported S-NSSAI.</p> | +| d) Measurement Result | <p>Each measurement is an integer value representing the number of bits measured in kbits (1kbits=1000 bits). The number of measurements is equal to the number of PLMNs multiplied by the number of QoS levels multiplied by the number of S-NSSAIs.</p> | +| e) Measurement Type | <p>The measurement name has the form DRB.RlcSduTransmittedVolumeDL_Filter.</p> <p>Where filter is a combination of PLMN ID and QoS level and S-NSSAI.</p> <p>Where PLMN ID represents the PLMN ID, QoS represents the mapped 5QI or the QCI level, and SNSSAI represents S-NSSAI.</p> | +| f) Measurement Object Class | NRCelIDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | <p>One usage of this measurement is for performance assurance within integrity area (user plane connection quality).</p> | + +### 7.10.2 UL Transmitted Data Volume (RLC SDU) + +| Measurement Name | UL Transmitted Data Volume (RLC SDU) | +|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | <p>This measurement provides the transmitted data volume in the uplink in a certain period. The measurement is split into subcounters per QoS level (mapped 5QI or QCI in EN-DC), and subcounters per supported S-NSSAI.</p> <p>The unit is kbit.</p> | +| b) Collection Method | CC | +| c) Condition | <p>This measurement is obtained by counting the data volume counted on RLC SDU level, in kbit successfully transmitted (acknowledged by E2 Node) in UL for one DRB during measurement time T. Separate counters are maintained for each mapped 5QI (or QCI for option 3) and for each supported S-NSSAI.</p> | +| d) Measurement Result | <p>Each measurement is an integer value representing the number of bits measured in kbits (1kbits=1000 bits). The number of measurements is equal to the number of PLMNs multiplied by the number of QoS levels multiplied by the number of S-NSSAIs.</p> | +| e) Measurement Type | <p>The measurement name has the form DRB.RlcSduTransmittedVolumeUL_Filter.</p> <p>Where filter is a combination of PLMN ID and QoS level and S-NSSAI.</p> <p>Where PLMN ID represents the PLMN ID, QoS represents the mapped 5QI or the QCI level, and SNSSAI represents S-NSSAI.</p> | +| f) Measurement Object Class | NRCelIDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | <p>One usage of this measurement is for performance assurance within integrity area (user plane connection quality).</p> | + +### 7.10.3 Distribution of Percentage of DL Transmitted Data Volume to Incoming Data Volume + +| Measurement Name | Distribution of Percentage of DL Transmitted Data Volume to Incoming Data Volume | +|-----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | This measurement provides the distribution of the percentage of successfully transmitted data volume to incoming data volume in downlink for UEs. The measurement is split into subcounters per QoS level (mapped 5QI or QCI in EN-DC), and subcounters per supported S-NSSAI. | +| b) Collection Method | CC | +| c) Condition | <p>The Measurement is calculated by <math>100 \cdot x/y</math> for each UE.</p> <p>x is incremented by counting the number of bits counted on RLC SDU level successfully transmitted (acknowledged by UE) in DL for one DRB during measurement time T.</p> <p>y is incremented by counting the number of bits entering the RLC layers in DL for one DRB during measurement time T.</p> <p>For each UE, the bin corresponding to the percentage of transmitted data volume to incoming data volume (<math>100 \cdot x/y</math>) experienced by the UE is incremented by one.</p> <p>Separate counters are maintained for each mapped 5QI (or QCI for option 3) and for each supported S-NSSAI.</p> | +| d) Measurement Result | A set of integers, each representing the (integer) number of samples with a percentage of DL transmitted data volume to incoming data volume in the range represented by that bin. If the optional QoS level subcounter and S-NSSAI subcounter and PLMN ID subcounter measurements are performed, the number of measurements is equal to the number of mapped 5QIs and the number of supported S-NSSAIs, and the number of PLMN IDs. | +| e) Measurement Type | The measurement name has the form DRB.PerDataVolumeDLDist.Bin where Bin represents the bin, or optionally DRB.PerDataVolumeDLDist.Bin.QOS, where QOS identifies the target quality of service class, and DRB.PerDataVolumeDLDist.Bin.SNSSAI, where SNSSAI identifies the S-NSSAI, and DRB.PerDataVolumeDLDist.Bin.PLMN, where PLMN identifies the PLMN ID. | +| f) Measurement Object Class | NRCellIDU | +| g) Switching Technology | Packet Switched | +| h) Generation | 5GS | +| i) Purpose | Network Operator's Traffic Engineering Community | + +### 7.10.4 Distribution of Percentage of UL Transmitted Data Volume to Incoming Data Volume + +| Measurement Name | Distribution of Percentage of UL Transmitted Data Volume to Incoming Data Volume | +|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | This measurement provides the distribution of the percentage of successfully transmitted data volume to incoming data volume in uplink for UEs. The measurement is split into subcounters per QoS level (mapped 5QI or QCI in EN-DC), and subcounters per supported S-NSSAI. | +| b) Collection Method | CC | +| c) Condition | <p>The Measurement is calculated by <math>100 \cdot x/y</math> for each UE.</p> <p>x is incremented by counting the number of bits counted on RLC SDU level successfully transmitted (acknowledged by E2 Node) in UL for one DRB during measurement time T.</p> <p>y is incremented by counting the number of bits entering the RLC layers in UL for one DRB during measurement time T. It is up to implementation how to measure y reliably during T.</p> <p>For each UE, the bin corresponding to the percentage of transmitted data volume to incoming data volume (<math>100 \cdot x/y</math>) experienced by the UE is incremented by one.</p> <p>Separate counters are maintained for each mapped 5QI (or QCI for option 3) and for each supported S-NSSAI.</p> | +| d) Measurement Result | A set of integers, each representing the (integer) number of samples with a percentage of UL transmitted data volume to incoming data volume in the range represented by that bin. If the optional QoS level subcounter and S-NSSAI subcounter and PLMN ID subcounter measurements are performed, the number of measurements is equal to the number of mapped 5QIs and the number of supported S-NSSAIs, and the number of PLMN IDs. | +| e) Measurement Type | The measurement name has the form DRB.PerDataVolumeULDist.Bin where Bin represents the bin, or optionally DRB.PerDataVolumeULDist.Bin.QOS, where QOS identifies the target quality of service class, and DRB.PerDataVolumeULDist.Bin.SNSSAI, where SNSSAI identifies the S-NSSAI, and DRB.PerDataVolumeUIDist.Bin.PLMN, where PLMN identifies the PLMN ID. | +| f) Measurement Object Class | NRCellIDU | +| g) Switching Technology | Packet Switched | +| h) Generation | 5GS | +| i) Purpose | Network Operator's Traffic Engineering Community | + +### 7.10.5 Distribution of DL Packet Drop Rate + +| Measurement Name | Distribution of DL Packet Drop Rate | +|-----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | This measurement provides the fraction of RLC SDU packets which are dropped on the downlink, due to high traffic load, traffic management etc in the gNB-DU. Only user-plane traffic (DTCH) is considered. A dropped packet is one without any part of it having been transmitted on the air interface. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC), and subcounters per supported S-NSSAI. | +| b) Collection Method | SI | +| c) Condition | This attribute is created by counting the number of UEs experiencing a certain packet loss rate in each range. | +| d) Measurement Result | Each measurement is an integer value representing the drop rate multiplied by 1E6 of each UE within the range of the bin. The number of measurements is equal to one. If the optional QoS and S-NSSAI level measurement are performed, the measurements are equal to the number of mapped 5QIs and the number of supported S-NSSAIs. | +| e) Measurement Type | The measurement name has the form DRB.RlcPacketDropRateDLDist and optionally DRB.RlcPacketDropRateDLDist.QOS where QOS identifies the target quality of service class, and DRB.RlcPacketDropRateDLDist.SNSSAI where SNSSAI identifies the S-NSSAI. | +| f) Measurement Object Class | NRCellDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for performance assurance within integrity area (user plane connection quality). | + +### 7.10.6 Distribution of UL Packet Loss Rate + +| Measurement Name | Distribution of UL Packet Loss Rate | +|-----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | This measurement provides the distribution of the fraction of PDCP SDU packets which are not successfully received at gNB-CU-UP. It is a measure of the UL packet loss including any packet losses in the air interface, in the gNB-CU and on the F1-U interface. Only user-plane traffic (DTCH) and only PDCP SDUs that have entered PDCP (and given a PDCP sequence number) are considered. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC), and subcounters per supported S-NSSAI. | +| b) Collection Method | SI | +| c) Condition | This attribute is created by counting the number of UEs experiencing a certain packet loss rate in each range. | +| d) Measurement Result | Each measurement is an integer value representing the loss rate multiplied by 1E6 of each UE within the range of the bin. If the optional QoS and S-NSSAI level measurement are performed, the measurements are equal to the number of mapped 5QIs and the number of supported S-NSSAIs. | +| e) Measurement Type | The measurement name has the form DRB.PacketLossRateULDIST and optionally DRB.PacketLossRateULDIST.QOS where QOS identifies the target quality of service class, and DRB. PacketLossRateULDIST.SNSSAI where SNSSAI identifies the S-NSSAI. | +| f) Measurement Object Class | GNBCUUPFunction.<br>NRCellCU. | +| g) Switching Technology | Valid for packet switched traffic. | +| h) Generation | 5GS. | +| i) Purpose | One usage of this measurement is for performance assurance within integrity area (user plane connection quality). | + +### 7.10.7 DL Synchronization Signal based Reference Signal Received Power (SS-RSRP) + +| Measurement Name | DL Synchronization Signal based Reference Signal Received Power (SS-RSRP) | +|-----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | This measurement provides the average of the DL SS-RSRP (see TS 38.215 [16]) values reported from UEs in the cell when SS-RSRP is used for L1-RSRP as configured by reporting configurations as defined in TS 38.214 [18], in case the L1-RSRP report function is enabled. Separate counters are maintained for each SSB in the cell. | +| b) Collection Method | DER (N=1) | +| c) Condition | This measurement is obtained by taking the average of the reported DL SS-RSRP values (i.e. between RSRP_0 and RSRP_126, see Table 10.1.6.1-1 in TS 38.133 [17]) from UEs in the cell per SSB during a granularity period. | +| d) Measurement Result | Each counter is a real value representing the average of the reported DL SS-RSRP values (i.e. between RSRP_0 and RSRP_126, see Table 10.1.6.1-1 in TS 38.133 [17]) for each SSB. The number of measurements is equal to the number of SSB beams defined in the cell. | +| e) Measurement Type | The measurement name has the form L1M.DL-SS-RSRP.SSB, where SSB represents the counter associated with SSB. | +| f) Measurement Object Class | NRCelIDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for mMIMO Non-GoB optimization in [21]. | + +### 7.10.8 DL Synchronization Signal based Signal to Noise and Interference Ratio (SS-SINR) + +| Measurement Name | DL Synchronization Signal based Signal to Noise and Interference Ratio (SS-SINR) | +|-----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | This measurement provides the average of the DL SS-SINR (see TS 38.215 [16]) values reported from UEs in the cell when SS-SINR is used for L1-SINR as configured by reporting configurations as defined in TS 38.214 [18], in case the L1-SINR report function is enabled. Separate counters are maintained for each SSB in the cell. | +| b) Collection Method | DER (N=1) | +| c) Condition | This measurement is obtained by taking the average of the reported DL SS-SINR values (i.e. between SINR_0 and SINR_127, see Table 10.1.16.1-1 in TS 38.133 [17]) from UEs in the cell per SSB during a granularity period. | +| d) Measurement Result | Each counter is an real value representing the average of the reported DL SS-SINR values (i.e. between SINR_0 and SINR_127, see Table 10.1.16.1-1 in TS 38.133 [17]) for each SSB. The number of measurements is equal to the number of SSB beams defined in the cell. | +| e) Measurement Type | The measurement name has the form L1M.DL-SS-SINR.SSB, where SSB represents the counter associated with SSB. | +| f) Measurement Object Class | NRCelIDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for mMIMO Non-GoB optimization in [21]. | + +### 7.10.9 UL Sounding Reference Signal based Reference Signal Received Power (SRS-RSRP) + +| Measurement Name | UL Sounding Reference Signal based Reference Signal Received Power (SRS-RSRP) | +|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | This measurement provides the average of the UL SRS-RSRP (see TS 38.215 [16]) values measured for UEs in the cell. | +| b) Collection Method | DER (N=1) | +| c) Condition | This measurement is obtained by taking the average of the measured UL SRS-RSRP values for UEs in the cell during a granularity period. | +| d) Measurement Result | The measurement is an real value representing the average of the measured UL SRS-RSRP values. | +| e) Measurement Type | The measurement name has the form L1M.UL-SRS-RSRP. | +| f) Measurement Object Class | NRCelIDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for mMIMO Non-GoB optimization in [21]. | + +### 7.10.10 Total number of scheduled time slots + +#### 7.10.10.1 Cell-specific DL Total transmission time duration + +| Measurement Name | Cell-specific DL total transmission time duration | +|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | <p>This measurement provides the total duration of time that covers the total number of time slots within each measurement granularity period, when one or more transport blocks were scheduled for HARQ downlink transmission (including HARQ retransmission) from the radio resources of a given component carrier (i.e., a given cell) to the UEs.</p> <p>The total number of time slots scheduled for a UE includes the unique time slots scheduled from the component carrier, irrespective of whether it is the primary component carrier (i.e., the primary cell) or a secondary supplemental component carrier (i.e., the secondary cell) to the UE, for downlink transmission of one or more transport blocks to the UE.</p> <p>The unit is in micro-second [<math>\mu</math>s].</p> <p>The measurement is optionally split into sub-counters per QoS level (mapped 5QI or QCI in EN-DC) and sub-counters per supported S-NSSAI, and sub-counters per PLMN ID, and sub-counters from BWP.</p> | +| b) Collection Method | CC | +| c) Condition | <p>The counter is incremented by the length of the time slot (in micro-seconds) during every time slot, when a HARQ downlink transmission is scheduled on the radio resources of the cell to one or more UEs served by the cell, either in its capacity as the primary cell or a secondary cell for the UEs.</p> <p>For this counter to be generated at a per-UE level, the counter is incremented by the length of the time slot (in micro-seconds), during every time slot when a HARQ transmission is scheduled on the radio resources of the cell to the given UE served by the cell, either in its capacity as the primary cell or a secondary cell for the UE.</p> | +| d) Measurement Result | <p>Each measurement is a single integer value.</p> <p>If optional measurements with sub-counters are performed, the number of measurements is equal to the number of supported QoS levels, the number of supported S-NSSAIs, the number of supported PLMNs, and the number of supported BWPs.</p> | +| e) Measurement Type | The measurement name has the form: ScheduledTxTimeDI (as the default measurement, without sub-counters or filters), or optionally, ScheduledTxTimeDI.QOS, where QOS identifies the target quality of service class, ScheduledTxTimeDI.SNSSAI, where SNSSAI identifies the S-NSSAI, and ScheduledTxTimeDI.PLMN, where PLMN refers to the PLMN ID, and ScheduledTxTimeDI.BWP, where BWP identifies the active BWP. | +| f) Measurement Object Class | NRCelIDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for performance assurance within integrity area (user plane connection quality). | + +#### 7.10.10.2 Cell-specific downlink total failed transmission time duration + +| Measurement Name | Cell-specific DL total failed transmission time duration | +|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | <p>This measurement provides the total duration of time that covers the total number of time slots within each measurement granularity period, when one or more transport blocks were unsuccessfully transmitted in the downlink from the radio resources of a given component carrier (i.e., a given cell) to the UEs, resulting in HARQ NACKs from the UEs.</p> <p>For a given UE, this measurement indicates the total number of unique time slots scheduled from the component carrier, irrespective of whether it is the primary component carrier (i.e., the primary cell) or a secondary supplemental component carrier (i.e., the secondary cell) to the UE, which resulted in unsuccessful transmission of one or more transport blocks to the UE.</p> <p>The unit is In micro-second [<math>\mu</math>s].</p> <p>The measurement is optionally split into sub-counters per QoS level (mapped 5QI or QCI in EN-DC) and sub-counters per supported S-NSSAI, and sub-counters per PLMN ID, and sub-counters from BWP.</p> | +| b) Collection Method | CC | +| c) Condition | <p>The counter is incremented by the length of the time slot (in micro-seconds) during every time slot, when the O-DU receives a NACK from any UE for a HARQ downlink transmission from the radio resources of the cell to the UE, irrespective of whether the cell serves the UE as the primary component carrier (i.e., the primary cell) or a secondary supplemental component carrier (i.e., the secondary cell).</p> <p>For this counter to be generated at a per-UE level, the counter is incremented by the length of the time slot (in micro-seconds) during every time slot, when the O-DU receives a NACK from the UE for a HARQ downlink transmission from the radio resources of the cell to the UE, irrespective of whether the cell serves the UE as the primary component carrier (i.e., the primary cell) or a secondary supplemental component carrier (i.e., the secondary cell).</p> | +| d) Measurement Result | Each measurement is a single integer value. If optional measurements with sub-counters are performed, the number of measurements is equal to the number of supported QoS levels, the number of supported S-NSSAIs, the number of supported PLMNs, and the number of supported BWPs. | +| e) Measurement Type | The measurement name has the form: FailedTxTimeDI (as the default measurement, without sub-counters or filters), or optionally, FailedTxTimeDI.QOS, where QOS identifies the target quality of service class, FailedTxTimeDI.SNSSAI, where SNSSAI identifies the S-NSSAI, and FailedTxTimeDI.PLMN, where PLMN refers to the PLMN ID, and FailedTxTimeDI.BWP, where BWP identifies the active BWP. | +| f) Measurement Object Class | NRCelIDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for performance assurance within integrity area (user plane connection quality). | + +#### 7.10.10.3 Cell-specific downlink retransmission time duration + +| Measurement Name | Cell-specific DL retransmission time duration | +|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | <p>This measurement provides the total duration of time covering the total number of time slots within each measurement granularity period, when one or more previously-unsuccessfully-transmitted transport blocks were scheduled for HARQ retransmission in the downlink from the radio resources of a given component carrier (i.e., a given cell) to the UEs.</p> <p>The total number of time slots scheduled for a UE includes the unique time slots scheduled from the component carrier in the downlink, irrespective of whether it is the primary component carrier (i.e., the primary cell) or a secondary supplemental component carrier (i.e., the secondary cell) to the UE, for HARQ retransmission of one or more transport blocks to the UE.</p> <p>The unit is in micro-second [<math>\mu</math>s].</p> <p>The measurement is optionally split into sub-counters per QoS level (mapped 5QI or QCI in EN-DC) and sub-counters per supported S-NSSAI, and sub-counters per PLMN ID, and sub-counters from BWP.</p> | +| b) Collection Method | CC | +| c) Condition | <p>The counter is incremented by the length of the time slot (in micro-seconds) during every time slot, when a HARQ downlink re-transmission of one or more previously-unsuccessfully-transmitted transport blocks is scheduled on the radio resources of the cell to one or more UEs served by the cell, either in its capacity as the primary cell or a supplemental secondary cell for the UEs.</p> <p>For this counter to be generated at a per-UE level, the counter is incremented by the length of the time slot (in micro-seconds), during every time slot when a HARQ downlink re-transmission of one or more previously-unsuccessfully-transmitted transport blocks is scheduled on the radio resources of the cell to the given UE served by the cell, either in its capacity as the primary cell or a supplemental secondary cell for the UE.</p> | +| d) Measurement Result | Each measurement is a single integer value. If optional measurements with sub-counters are performed, the number of measurements is equal to the number of supported QoS levels, the number of supported S-NSSAIs, the number of supported PLMNs, and the number of supported BWPs. | +| e) Measurement Type | The measurement name has the form: ScheduledReTxTimeDI(as the default measurement, without sub-counters or filters), or optionally, ScheduledReTxTimeDI.QOS , where QOS identifies the target quality of service class, ScheduledReTxTimeDI.SNSSAI where SNSSAI identifies the S-NSSAI, and ScheduledReTxTimeDI.PLMN, where PLMN refers to the PLMN ID, andScheduledReTxTimeDI.BWP , where BWP identifies the active BWP. | +| f) Measurement Object Class | NRCellDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for performance assurance within integrity area (user plane connection quality). | + +#### 7.10.10.4 Cell-specific downlink total SU-MIMO transmission time duration + +| Measurement Name | Cell-specific DL total SU-MIMO transmission time duration | +|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | <p>This measurement provides the total duration of time that covers the total number of time slots within each measurement granularity period, when multiple transport blocks were scheduled for HARQ downlink transmission in SU-MIMO mode from the radio resources of a given component carrier (i.e., a given cell) to the UEs.</p> <p>The total number of time slots scheduled for a UE includes the unique time slots scheduled from the component carrier, irrespective of whether it is the primary component carrier (i.e., the primary cell) or a secondary supplemental component carrier (i.e., the secondary cell) to the UE, for transmission of multiple transport blocks in SU-MIMO mode to the UE.</p> <p>The unit is in micro-second [<math>\mu</math>s].</p> <p>The measurement is optionally split into sub-counters per QoS level (mapped 5QI or QCI in EN-DC) and sub-counters per supported S-NSSAI, and sub-counters per PLMN ID, and sub-counters from BWP.</p> | +| b) Collection Method | CC | +| c) Condition | <p>The counter is incremented by the length of the time slot (in micro-seconds) during every time slot, when a HARQ downlink transmission of multiple transport blocks in SU-MIMO mode is scheduled on the radio resources of the cell to one or more UEs served by the cell, either in its capacity as the primary cell or a secondary cell for the UEs.</p> <p>For this counter to be generated at a per-UE level, the counter is incremented by the length of the time slot (in micro-seconds), during every time slot when a HARQ downlink transmission of multiple transport blocks in SU-MIMO mode is scheduled on the radio resources of the cell to the given UE served by the cell, either in its capacity as the primary cell or a secondary cell for the UE.</p> | +| d) Measurement Result | Each measurement is a single integer value. If optional measurements with sub-counters are performed, the number of measurements is equal to the number of supported QoS levels, the number of supported S-NSSAIs, the number of supported PLMNs, and the number of supported BWPs. | +| e) Measurement Type | The measurement name has the form: ScheduledTxTimeDISUMIMO (as the default measurement, without sub-counters or filters), or optionally, ScheduledTxTimeDISUMIMO.QOS, where QOS identifies the target quality of service class, ScheduledTxTimeDISUMIMO.SNSSAI, where SNSSAI identifies the S-NSSAI, and ScheduledTxTimeDISUMIMO.PLMN, where PLMN refers to the PLMN ID, and ScheduledTxTimeDISUMIMO.BWP, where BWP identifies the active BWP. | +| f) Measurement Object Class | NRCellIDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for performance assurance within integrity area (user plane connection quality). | + +#### 7.10.10.5 Cell-specific downlink total MU-MIMO transmission time duration + +| Measurement Name | Cell-specific DL total MU-MIMO transmission time duration | +|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | <p>This measurement provides the total duration of time covering the total number of time slots within each measurement granularity period, when multiple transport blocks were scheduled for HARQ downlink transmission in MU-MIMO mode from the radio resources of a given component carrier (i.e., a given cell) to the UEs.</p> <p>The total number of time slots scheduled for a UE includes the unique time slots scheduled from the component carrier, irrespective of whether it is the primary component carrier (i.e., the primary cell) or a secondary supplemental component carrier (i.e., the secondary cell) to the UE, for transmission of downlink transport blocks to the UE when the UE is in MU-MIMO mode.</p> <p>The unit is in micro-second [<math>\mu</math>s].</p> <p>The measurement is optionally split into sub-counters per QoS level (mapped 5QI or QCI in EN-DC) and sub-counters per supported S-NSSAI, and sub-counters per PLMN ID, and sub-counters from BWP.</p> | +| b) Collection Method | CC | +| c) Condition | <p>The counter is incremented by the length of the time slot (in micro-seconds) during every time slot, when a HARQ downlink transmission of multiple transport blocks in MU-MIMO mode is scheduled on the radio resources of the cell to multiple UEs served by the cell, either in its capacity as the primary cell or a secondary cell for the UEs.</p> <p>For this counter to be generated at a per-UE level, the counter is incremented by the length of the time slot (in micro-seconds), during every time slot when the UE is configured in MU-MIMO mode and when a HARQ downlink transmission of transport blocks is scheduled on the radio resources of the cell to the given UE served by the cell, either in its capacity as the primary cell or a secondary cell for the UE.</p> | +| d) Measurement Result | Each measurement is a single integer value. If optional measurements with sub-counters are performed, the number of measurements is equal to the number of supported QoS levels, the number of supported S-NSSAIs, the number of supported PLMNs, and the number of supported BWPs. | +| e) Measurement Type | The measurement name has the form: ScheduledTxTimeDIMUMIMO (as the default measurement, without sub-counters or filters), or optionally, ScheduledTxTimeDIMUMIMO.QOS, where QOS identifies the target quality of service class, ScheduledTxTimeDIMUMIMO.SNSSAI, where SNSSAI identifies the S-NSSAI, and ScheduledTxTimeDIMUMIMO.PLMN, where PLMN refers to the PLMN ID, and ScheduledTxTimeDIMUMIMO.BWP, where BWP identifies the active BWP. | +| f) Measurement Object Class | NRCelIDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for performance assurance within integrity area (user plane connection quality). | + +### 7.10.11 DL Transmitted Data Volume (MAC SDU) + +| Measurement Name | DL Transmitted Data Volume (MAC SDU) | +|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | <p>This measurement provides the transmitted data volume in the downlink in a measurement time. The measurement is split into subcounters per PLMN ID and subcounters per QoS level (mapped 5QI or QCI in NR option 3), and subcounters per supported S-NSSAI.</p> <p>The unit is kbit.</p> | +| b) Collection Method | CC | +| c) Condition | This measurement is obtained by counting the data volume counted on MAC SDU level, in kbit successfully transmitted (reception of HARQ ACK) in DL for one DRB during measurement time T. Separate counters are maintained for each mapped 5QI (or QCI for option 3) and for each supported S-NSSAI. | +| d) Measurement Result | Each measurement is an integer value representing the number of bits measured in kbits (1kbits=1000 bits). The number of measurements is equal to the number of PLMNs multiplied by the number of QoS levels multiplied by the number of S-NSSAIs. | +| e) Measurement Type | <p>The measurement name has the form DRB.MacSduTransmittedVolumeDL_Filter.</p> <p>Where filter is a combination of PLMN ID and QoS level and S-NSSAI.</p> <p>Where PLMN ID represents the PLMN ID, QoS represents the mapped 5QI or the QCI level, and SNSSAI represents S-NSSAI.</p> | +| f) Measurement Object Class | NRCellDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for performance assurance within integrity area (user plane connection quality). | + +### 7.10.12 UL Transmitted Data Volume (MAC SDU) + +| Measurement Name | UL Transmitted Data Volume (MAC SDU) | +|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| a) Description | <p>This measurement provides the transmitted data volume in the uplink in a certain period. The measurement is split into subcounters per QoS level (mapped 5QI or QCI in NR option 3), and subcounters per supported S-NSSAI.</p> <p>The unit is kbit.</p> | +| b) Collection Method | CC | +| c) Condition | This measurement is obtained by counting the data volume counted on MAC SDU level, in kbit successfully transmitted (transmission of HARQ ACK) in UL for one DRB during measurement time T. Separate counters are maintained for each mapped 5QI (or QCI for option 3) and for each supported S-NSSAI. | +| d) Measurement Result | Each measurement is an integer value representing the number of bits measured in kbits (1kbits=1000 bits). The number of measurements is equal to the number of PLMNs multiplied by the number of QoS levels multiplied by the number of S-NSSAIs. | +| e) Measurement Type | <p>The measurement name has the form DRB.MacSduTransmittedVolumeUL_Filter.</p> <p>Where filter is a combination of PLMN ID and QoS level and S-NSSAI.</p> <p>Where PLMN ID represents the PLMN ID, QoS represents the mapped 5QI or the QCI level, and SNSSAI represents S-NSSAI.</p> | +| f) Measurement Object Class | NRCelIDU | +| g) Switching Technology | Valid for packet switched traffic | +| h) Generation | 5GS | +| i) Purpose | One usage of this measurement is for performance assurance within integrity area (user plane connection quality). | + +# 8 Elements for E2SM Service Model + +## 8.1 General + +Clause 8.2 describes the structure of the information elements as required for E2SM-KPM in tabular format. Clause 8.3 presents individual information elements. Clause 8.4 provides the corresponding ASN.1 definition of each information element. + +The following attributes are used for the tabular description of the messages and information elements: + +NOTE: The messages have been defined by the guidelines specified in 3GPP TR 25.921 [i.3]. + +## 8.2 Message Functional Definition and Content + +### 8.2.1 Messages for RIC Functional procedures + +#### 8.2.1.1 RIC EVENT TRIGGER DEFINITION IE + +This information element is part of the RIC SUBSCRIPTION REQUEST message sent by the Near-RT RIC to an E2 Node and is required for event triggers used to initiate REPORT actions. + +Direction: NEAR-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE <i>Event Trigger Format</i> | M | | | | +| >E2SM-KPM Event Trigger Definition Format 1 | | | 8.2.1.1.1 | | + +##### 8.2.1.1.1 E2SM-KPM Event Trigger Definition Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|-------------------------|-------------------------------------------------------------| +| Reporting Period | M | | INTEGER (1..4294967295) | The reporting period is expressed in unit of 1 millisecond. | + +#### 8.2.1.2 RIC ACTION DEFINITION IE + +This information element is part of the RIC SUBSCRIPTION REQUEST message sent by the Near-RT RIC to an E2 Node. In this service model, this information element provides additional information for the nominated Action (Report). + +Direction: NEAR-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|----------|-------|-----------------------|---------------------------------------------------------------------------| +| RIC Style Type | M | | 8.3.3 | | +| CHOICE <i>Action Definition Format</i> | M | | | | +| >E2SM-KPM Action Definition Format 1 | | | 8.2.1.2.1 | | +| >E2SM-KPM Action Definition Format 2 | | | 8.2.1.2.2 | | +| >E2SM-KPM Action Definition Format 3 | | | 8.2.1.2.3 | | +| >E2SM-KPM Action Definition Format 4 | | | 8.2.1.2.4 | | +| >E2SM-KPM Action Definition Format 5 | | | 8.2.1.2.5 | | +| >E2SM-KPM Action Definition Format 255 | | | 8.2.1.2.6 | Used to generate list of fundamental level E2SM-KPM Action Definition IEs | + +##### 8.2.1.2.1 E2SM-KPM Action Definition Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------------|----------|---------------------------------|--------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Information List | | 1..<br><maxnoofMeasurementInfo> | | | +| >CHOICE <i>Measurement Type</i> | M | | | | +| >>Measurement Name | | | 8.3.9<br>Measurement Type Name | | +| >>Measurement ID | | | 8.3.10<br>Measurement Type ID | | +| >List of Labels | | 1..<br><maxnoofLabelInfo> | | | +| >>Label Information | M | | 8.3.11<br>Measurement Label | | +| >Matching Condition for Reporting | | 0..<br><maxnoofConditionInfo> | | | +| >>Measured Value Reporting Condition | M | | 8.3.28 | | +| >>Logical OR | O | | 8.3.25 | | +| Granularity Period | M | | 8.3.8<br>Granularity Period | Collection interval of measurements | +| Cell Global ID | O | | 8.3.20 Cell Global ID | Points to a specific cell for generating measurements subscribed by the <i>Measurement Information List</i> IE. This IE is ignored when Report Style 255 is used, <i>Common Action Definition</i> IE is present and for the specific job, <i>Job Specific Action Definition</i> IE is absent and <i>Job Specific Cell Global ID</i> IE is present. | +| Distribution Measurement Bin Range Info List | | 0..<br><maxnoofMeasurementInfo> | | | +| >CHOICE <i>Measurement Type</i> | M | | | | +| >>Measurement Name | | | 8.3.9<br>Measurement Type Name | | +| >>Measurement ID | | | 8.3.10<br>Measurement Type ID | | +| >Bin Range Definition | M | | 8.3.26 | Indicates the value ranges of bins for distribution type measurement | + +| Range bound | Explanation | +|------------------------|---------------------------------------------------------------------------------------------------------------| +| maxnoofMeasurementInfo | Maximum no. of measurement types that can be reported by a single report. Value is <65535>. | +| maxnoofLabelInfo | Maximum no. of measurements values that can be reported for a single measurement type. Value is <2147483647>. | +| maxnoofConditionInfo | Maximum no. of conditions that can be subscribed for a single measurement type. Value is <32768>. | + +##### 8.2.1.2.2 E2SM-KPM Action Definition Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------|----------|-------|-----------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| UE ID | M | | 8.3.24 | Points to a specific UE of interest. This IE is ignored when Report Style 255 is used, <i>Common Action Definition</i> IE is present and for the specific job, <i>Job Specific Action Definition</i> IE is absent and <i>Job Specific UE ID</i> IE is present. | +| Subscription Information | M | | 8.2.1.2.1 E2SM-KPM Action Definition Format 1 | | + +##### 8.2.1.2.3 E2SM-KPM Action Definition Format 3 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|----------|---------------------------------|-----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Information Condition List | | 1..<br><maxnoofMeasurementInfo> | | | +| >CHOICE <i>Measurement Type</i> | M | | | | +| >>Measurement Name | | | 8.3.9<br>Measurement Type Name | | +| >>Measurement ID | | | 8.3.10<br>Measurement Type ID | | +| >Matching Condition | | 1..<br><maxnoofConditionInfo> | | The Matching Condition represents the Boolean expression, the logical connection to the next condition is AND if the <i>Logical OR</i> IE is not included | +| >>CHOICE <i>Condition Type</i> | M | | | | +| >>>Label Information | | | 8.3.11<br>Measurement Label | | +| >>>Test Information | | | 8.3.22 Test Condition Information | | +| >>Logical OR | O | | 8.3.25 | If included, logical connection to the next condition is “or”. | +| >Bin Range Definition | O | | 8.3.26 | Indicates the value ranges of bins for distribution type measurement | +| Granularity Period | M | | 8.3.8<br>Granularity Period | Collection interval of measurements | +| Cell Global ID | O | | 8.3.20 Cell Global ID | Points to a specific cell for generating measurements subscribed by the <i>Measurement Information List</i> IE. This IE is ignored when Report Style 255 is used, <i>Common Action Definition</i> IE is present and for the specific job, <i>Job Specific Action Definition</i> IE is absent and <i>Job Specific Cell Global ID</i> IE is present. | + +| Range bound | Explanation | +|------------------------|---------------------------------------------------------------------------------------------------| +| maxnoofMeasurementInfo | Maximum no. of measurement types that can be reported by a single report. Value is <65535>. | +| maxnoofConditionInfo | Maximum no. of conditions that can be subscribed for a single measurement type. Value is <32768>. | + +##### 8.2.1.2.4 E2SM-KPM Action Definition Format 4 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------|----------|-------------------------------------|-----------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Matching Condition | | 1..<br><maxnoofConditionInfoPerSub> | | The Matching Condition represents the Boolean expression, the logical connection to the next condition is AND if the <i>Logical OR</i> IE is not included | +| >Test Information | M | | 8.3.22 Test Condition Information | Provides test condition to filter matching UEs | +| >Logical OR | O | | 8.3.25 | If included, logical connection to the next condition is “or”. | +| Subscription Information | M | | 8.2.1.2.1 E2SM-KPM Action Definition Format 1 | | + +| Range bound | Explanation | +|----------------------------|-----------------------------------------------------------------------------------------------| +| maxnoofConditionInfoPerSub | Maximum no. of conditions that can be subscribed for a single subscription. Value is <32768>. | + +##### 8.2.1.2.5 E2SM-KPM Action Definition Format 5 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|----------------------------|-----------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Subscribed UE IDs | | 2..<br><maxnoofUEIDPerSub> | | Points to a list of UEs of interest.<br>This IE is ignored when Report Style 255 is used, <i>Common Action Definition</i> IE is present and for the specific job, <i>Job Specific Action Definition</i> IE is absent and <i>Job Specific List of Subscribed UE IDs</i> IE is present. | +| >UE ID | M | | 8.3.24 | | +| Subscription Information | M | | 8.2.1.2.1 E2SM-KPM Action Definition Format 1 | | + +| Range bound | Explanation | +|-------------------|-------------------------------------------------------------------------------------------| +| maxnoofUEIDPerSub | Maximum no. of UE IDs that can be subscribed for a single subscription. Value is <65535>. | + +##### 8.2.1.2.6 E2SM-KPM Action Definition Format 255 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------|----------|----------------------|---------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Multi Report Action Definitions | | 1..<br><maxnoofJobs> | | | +| >Job ID | M | | 8.3.30 | | +| >Job Specific Action Definition | O | | 8.2.1.2 | Used to define the Action Definition for a specific job.<br>If absent, then <i>Common Action Definition</i> IE applies to specific job | +| >Job Specific Cell Global ID | O | | 8.3.20 | Used to modify the <i>Cell Global ID</i> IE within <i>Common Action Definition</i> IE.<br>To be provided when <i>Job Specific Action Definition</i> IE is not present for the specific job | +| >Job Specific UE ID | O | | 8.3.24 | Used to modify the <i>UE ID</i> IE within <i>Common Action Definition</i> IE.<br>To be provided when <i>Job Specific Action Definition</i> IE is not present for the specific job | +| >Job Specific List of Subscribed UE IDs | O | | | Used to modify the <i>List of Subscribed UE IDs</i> IE within <i>Common Action Definition</i> IE.<br>To be provided when <i>Job Specific Action Definition</i> IE is not present for the specific job | +| Reporting approach | M | | ENUMERATED<br>(Single, Multiple, ...) | Indicates if integrated report is to be transmitted as Single report or Multiple Reports with one per job | +| Common Action Definition | O | | 8.2.1.2 | Used to define a common Action Definition for one or more specific jobs.<br>To be provided when at least one job does not have <i>Job Specific Action Definition</i> IE present | + +| Range bound | Explanation | +|-------------|-------------------------------------------------------------------------------| +| maxnoofJobs | Maximum no. of fundamental levels jobs that can be reported. Value is <65535> | + +#### 8.2.1.3 RIC INDICATION HEADER IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to the Near-RT RIC and is required for REPORT action. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE <i>Indication Header Format</i> | M | | | | +| >E2SM-KPM Indication Header Format 1 | | | 8.2.1.3.1 | | + +##### 8.2.1.3.1 E2SM-KPM Indication Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------|----------|-------|--------------------------------------|-----------------------| +| Collection Start Time | M | | 8.3.12 Time Stamp | | +| File Format Version | O | | PrintableString (SIZE (0..15), ...) | | +| Sender Name | O | | PrintableString (SIZE (0..400), ...) | | +| Sender Type | O | | PrintableString (SIZE (0..8), ...) | | +| Vendor Name | O | | PrintableString (SIZE (0..32), ...) | | + +#### 8.2.1.4 RIC INDICATION MESSAGE IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to the Near-RT RIC and is required for REPORT action. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------|----------|-------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| CHOICE <i>Indication Message Format</i> | M | | | | +| >E2SM-KPM Indication Message Format 1 | | | 8.2.1.4.1 | | +| >E2SM-KPM Indication Message Format 2 | | | 8.2.1.4.2 | | +| >E2SM-KPM Indication Message Format 3 | | | 8.2.1.4.3 | | +| >E2SM-KPM Indication Message Format 255 | | | 8.2.1.4.4 | To be used when integrated report is to be transmitted as a single report | +| Job ID | O | | 8.3.30 | To be included when Integrated level service is being used with each job specific measurement report is sent as an independent RIC Indication message | + +##### 8.2.1.4.1 E2SM-KPM Indication Message Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------|----------|------------------------------------|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurements Data | | 1..<br><maxnoofMeasurementsRecord> | | Contains a set of Measurement Records, each collected at each Granularity Period. | +| >Measurements Record | | 1..<br><maxnoofMeasurementValue> | | Contains measured values in same order as in the <i>Measurements Information List</i> IE if present, otherwise in the order defined in the subscription. | +| >>CHOICE <i>Measured Value</i> | M | | | | +| >>>Integer Value | | | INTEGER (0..4294967295) | | +| >>>Real Value | | | REAL | | +| >>>No Value | | | NULL | Indicates that no measurement value was generated. | +| >>>Not Satisfied | | | NULL | Indicates that the measured value did not satisfy the Matching Condition for Reporting, if configured. | +| >Incomplete Flag | O | | ENUMERATED (true, ...) | Indicates that the measurements record is not reliable. | +| Measurement Information List | | 0..<br><maxnoofMeasurementInfo> | | | +| >CHOICE <i>Measurement Type</i> | M | | | | +| >>Measurement Name | | | 8.3.9 Measurement Type Name | | +| >>Measurement ID | | | 8.3.10 Measurement Type ID | | +| >List of Labels | | 1..<br><maxnoofLabelInfo> | | | +| >>Label Information | M | | 8.3.11 Measurement Label | | +| >Matching Condition for Reporting | | 0..<br><maxnoofConditionInfo> | | | +| >>Measured Value Reporting Condition | M | | 8.3.28 | | +| >>Logical OR | O | | 8.3.25 | | +| Granularity Period | O | | 8.3.8 Granularity Period | Collection interval of measurements | + +| Range bound | Explanation | +|--------------------------|---------------------------------------------------------------------------------------------------------------| +| maxnoofMeasurementInfo | Maximum no. of measurement types that can be reported by a single report. Value is <65535>. | +| maxnoofConditionInfo | Maximum no. of conditions that can be subscribed for a single measurement type. Value is <32768>. | +| maxnoofLabelInfo | Maximum no. of measurements values that can be reported for a single measurement type. Value is <2147483647>. | +| maxnoofMeasurementRecord | Maximum no. of measurement records that can be reported by a single report. Value is <65535>. | +| maxnoofMeasurementValue | Maximum no. of measurement values that can be carried by a single measurement record. Value is <2147483647>. | + +##### 8.2.1.4.2 E2SM-KPM Indication Message Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------------------|----------|-----------------------------------|-----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurements Data | | 1..<br><maxnoofMeasurementRecord> | | Contains a set of Measurement Records, each collected at each Granularity Period. | +| >Measurements Record | | 1..<br><maxnoofMeasurementValue> | | Contains measured values in same order as in the <i>Measurements Information Condition UE List</i> IE. | +| >>CHOICE <i>Measured Value</i> | M | | | | +| >>>Integer Value | | | INTEGER (0..4294967295) | | +| >>>Real Value | | | REAL | | +| >>>No Value | | | NULL | | +| >Incomplete Flag | O | | ENUMERATED (true, ...) | Indicates that the measurements record is not reliable. | +| Measurement Information Condition UE List | | 1..<br><maxnoofMeasurementInfo> | | | +| >CHOICE <i>Measurement Type</i> | M | | | | +| >>Measurement Name | | | 8.3.9 Measurement Type Name | | +| >>Measurement ID | | | 8.3.10 Measurement Type ID | | +| >Matching Condition | | 1..<br><maxnoofConditionInfo> | | | +| >>CHOICE <i>Condition Type</i> | M | | | | +| >>>Label Information | | | 8.3.11 Measurement Label | | +| >>>Test Information | | | 8.3.22 Test Condition Information | | +| >>Logical OR | O | | 8.3.25 | | +| >List of matched UE IDs | | 0..<br><maxnoofUEID> | | Indicates the UE ID(s) matched for the corresponding measurement type during the Reporting Period. | +| >>UE ID | M | | 8.3.24 | | +| >Sequence of Matched UE IDs for Granularity Periods | | 0..<br><maxnoofMeasurementRecord> | | Indicates the UE ID(s) matched for the corresponding measurement type, separately for each and every Granularity Period in chronological order.<br><br>If included, the <i>List of matched UE IDs</i> IE shall be ignored if received. | +| >>CHOICE <i>Matched UE for Granularity Period</i> | M | | | | +| >>>None | | | | | + +| | | | | | +|-------------------------------------------|---|--------------------------|-----------------------------|--------------------------------------------------------------------------------------------------------------------------| +| >>>>No UE matched for Granularity Period | M | | ENUMERATED (true, ...) | Indicates that none of UEs were matched for the corresponding measurement type for the corresponding Granularity Period. | +| >>>One or more | | | | | +| >>>>List of UE IDs for Granularity Period | | 1..<br><maxnoofUEID<br>> | | Indicates the UE ID(s) matched for the corresponding measurement type for the corresponding Granularity Period. | +| >>>>>UE ID | M | | 8.3.24 | | +| Granularity Period | O | | 8.3.8<br>Granularity Period | Collection interval of measurements | + +| Range bound | Explanation | +|--------------------------|--------------------------------------------------------------------------------------------------------------| +| maxnoofMeasurementInfo | Maximum no. of measurement types that can be reported by a single report. Value is <65535>. | +| maxnoofConditionInfo | Maximum no. of conditions that can be subscribed for a single measurement type. Value is <32768>. | +| maxnoofUEID | Maximum no. of UE IDs that can be reported for a single condition. Value is <65535>. | +| maxnoofMeasurementRecord | Maximum no. of measurement records that can be reported by a single report. Value is <65535>. | +| maxnoofMeasurementValue | Maximum no. of measurement values that can be carried by a single measurement record. Value is <2147483647>. | + +##### 8.2.1.4.3 E2SM-KPM Indication Message Format 3 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|----------------------------------|------------------------------------------------|------------------------------------------------------------| +| List of UE Measurement Reports | | 1..<br><maxnoofUEMeasureReports> | | | +| >UE ID | M | | 8.3.24 | | +| >Measurements Report | M | | 8.2.1.4.1 E2SM-KPM Indication Message Format 1 | Contains Measurement Data for a UE for a Reporting Period. | + +| Range bound | Explanation | +|---------------------|-------------------------------------------------------------------------------| +| maxnoofUEMeasReport | Maximum no. of UE Measurement Reports that can be reported. Value is <65535>. | + +##### 8.2.1.4.4 E2SM-KPM Indication Message Format 255 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------|----------|--------------------------|-----------------------|-----------------------------------------------| +| List of RIC Indication messages | | 1..<br><maxnoofJobs<br>> | | | +| >Job ID | M | | 8.3.30 | | +| >RIC Indication Message | M | | 8.2.1.4 | Contains Measurement report for specific Job. | + +| Range bound | Explanation | +|-------------|--------------------------------------------------------------------------------| +| maxnoofJobs | Maximum no. of fundamental levels jobs that can be reported. Value is <65535>. | + +#### 8.2.1.5 RIC CALL PROCESS ID + +Void. + +#### 8.2.1.6 RIC CONTROL HEADER IE + +Void. + +#### 8.2.1.7 RIC CONTROL MESSAGE IE + +Void. + +#### 8.2.1.8 RIC CONTROL OUTCOME IE + +Void. + +### 8.2.2 Messages for RIC Global Procedures + +#### 8.2.2.1 RAN Function Definition IE + +This information element is part of the E2 SETUP REQUEST, and RIC SERVICE UPDATE message sent by the E2 Node to the Near-RT RIC and is used to provide all required information for the Near-RT RIC to determine how a given E2 Node has been configured to support a given RAN Function specific E2SM. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------------|----------|------------------------------|------------------------|--------------------------------------------------------------------------------------------------------------| +| RAN Function Name | M | | 8.3.2 | | +| Sequence of Event Trigger styles | | 0.. <maxnoofRICStyles> | | | +| >RIC Event Trigger Style Type | M | | 8.3.3 | | +| >RIC Event Trigger Style Name | M | | 8.3.4 | | +| >RIC Event Trigger Format Type | M | | 8.3.5 | | +| Sequence of Report styles | | 0.. <maxnoofRICStyles> | | To be used to describe supported fundamental level report styles | +| >RIC Report Style Type | M | | 8.3.3 | | +| >RIC Report Style Name | M | | 8.3.4 | | +| >RIC Report Action Format Type | M | | 8.3.5 | | +| >Sequence of Measurement Info for Action | | 1.. <maxnoofMeasurementInfo> | | | +| >>Measurement Type Name | M | | 8.3.9 | | +| >>Measurement Type ID | O | | 8.3.10 | | +| >>Bin Range Definition | O | | 8.3.26 | Indicates the value ranges of bins for distribution type measurement | +| >RIC Indication Header Format Type | M | | 8.3.5 | Indication header type used by Report style | +| >RIC Indication Message Format Type | M | | 8.3.5 | Indication message type used by Report style | +| Sequence of Integrated level Report styles | | 0.. <maxnoofRICStyles> | | To be used to describe supported integrated level report styles | +| >RIC Report Style Type | M | | 8.3.3 | | +| >RIC Report Style Name | M | | 8.3.4 | | +| >RIC Report Action Format Type | M | | 8.3.5 | | +| >RIC Indication Header Format Type | M | | 8.3.5 | Indication header type used by Report style | +| >RIC Indication Message Format Type | M | | 8.3.5 | Indication message type used by Report style | +| >Sequence of Fundamental level report styles | | 0.. <maxnoofRICStyles> | | | +| >>RIC Report Style Type | M | | 8.3.3 | Supported features (formats, measurement info, etc.) defined in corresponding fundamental level Report Style | +| >>Job Specific Action Definition support | O | | ENUMERATED (true, ...) | | +| >>Job Specific Cell Global ID support | O | | ENUMERATED (true, ...) | | +| >>Job Specific UE ID support | O | | ENUMERATED (true, ...) | | +| >>Job Specific List of Subscribed UE IDs support | O | | ENUMERATED (true, ...) | | +| >Single Reporting approach support | O | | ENUMERATED (true, ...) | | +| >Multiple Reporting approach support | O | | ENUMERATED (true, ...) | | +| >Common Action Definition support | O | | ENUMERATED (true, ...) | | + +| Range bound | Explanation | +|------------------------|-----------------------------------------------------------------------------------------------------------------| +| maxnoofCells | Maximum no. of cells supported by an E2 Node component. The value is <16384>. | +| maxnoofRICstyle | Maximum no. of Style of Report, Insert, Control or Policy actions supported by RAN Function. The value is <63>. | +| maxnoofMeasurementInfo | Maximum no. of measurement types that can be reported by a single report. The value is <65535>. | + +## 8.3 Information Element definitions + +### 8.3.1 General + +When specifying information elements which are to be represented by bit strings, if not otherwise specifically stated in the semantics description of the concerned IE or elsewhere, the following principle applies with regards to the ordering of bits: + +- The first bit (leftmost bit) contains the most significant bit (MSB); +- The last bit (rightmost bit) contains the least significant bit (LSB); +- When importing bit strings from other specifications, the first bit of the bit string contains the first bit of the concerned information. + +### 8.3.2 RAN Function Name + +This IE is defined in [12] clause 6.2.2.1. + +### 8.3.3 RIC Style Type + +This IE is defined in [12] clause 6.2.2.2. + +### 8.3.4 RIC Style Name + +This IE is defined in [12] clause 6.2.2.3. + +### 8.3.5 RIC Format Type + +This IE is defined in [12] clause 6.2.2.4. + +### 8.3.6 Void + +### 8.3.7 Void + +### 8.3.8 Granularity Period + +This IE defines the measurement collection interval within a reporting period. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------|----------|-------|----------------------------|---------------------------------------------------------------------| +| Granularity Period | M | | INTEGER<br>(1..4294967295) | Measurement collection interval expressed in unit of 1 millisecond. | + +### 8.3.9 Measurement Type Name + +This IE defines the name of a given measurement type. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | M | | PrintableString(SIZE(1..150, ...)) | One of the measurement names specified in TS 28.552 [4], TS 32.425 [8], or clause 7.10. The subcounters are represented by the Measurement Labels defined in 8.3.11. | + +### 8.3.10 Measurement Type ID + +This IE defines the identifier of a given measurement type. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|--------------------------|-----------------------| +| Measurement ID | M | | INTEGER (1.. 65535, ...) | | + +### 8.3.11 Measurement Label + +This IE defines values of necessary subcounters applicable to an associated measurement type. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| No Label | O | | ENUMERATED (true, ...) | Indicates the associated measurement type without any subcounter. If included, other IEs in 8.3.11 shall not be included in the same Measurement Label (and vice versa). | +| PLMN ID | O | | 8.3.15 | Represents the PLMN subcounter | +| Slice ID | O | | 8.3.14 | Represents the SNSSAI subcounter. OCTET STRING of length 1 octet shall be provided for matching the SST value only. OCTET STRING of length 4 octets shall be provided for matching the SST + SD value. OCTET STRING of length 4 octets with the last 3 octets as 0FFFFFFF shall be provided if a S-NSSAI without SD value has to be explicitly matched. See 3GPP TS 23.003 [20] clause 28.4.2. | +| 5QI | O | | 8.3.17 | Represents the 5QI subcounter | +| QFI | O | | 8.3.21 | Represents the QFI subcounter | +| QCI | O | | 8.3.18 | Represents the QCI subcounter | +| QCImax | O | | 8.3.18 | Used only when the name of the associated measurement type ends with ' _Filter' | + +| | | | | | +|-------------------------------------|---|--|------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| QCImin | O | | 8.3.18 | Used only when the name of the associated measurement type ends with 'Filter' | +| ARPmax | O | | INTEGER (1.. 15, ...) | Used only when the name of the associated measurement type ends with 'Filter' | +| ARPmin | O | | INTEGER (1.. 15, ...) | Used only when the name of the associated measurement type ends with 'Filter' | +| Bitrate Range | O | | INTEGER (1.. 65535, ...) | Used only when the name of the associated measurement type ends with 'Filter' | +| Layer at MU-MIMO | O | | INTEGER (1.. 65535, ...) | Represents the MIMO layer subcounter | +| Sum | O | | ENUMERATED (true, ...) | Sum is calculated as cumulative sum from the start of the measurement. | +| Distribution Bin X | O | | INTEGER (1.. 65535, ...) | An index of Bin X. Only applicable to distribution type measurement information. | +| Distribution Bin Y | O | | INTEGER (1.. 65535, ...) | An index of Bin Y. Only applicable to distribution type measurement information. This IE may be present only when Distribution Bin X is present. | +| Distribution Bin Z | O | | INTEGER (1.. 65535, ...) | An index of Bin Z. Only applicable to distribution type measurement information. This IE may be present only when Distribution Bin X and Distribution Bin Y are present. | +| Precedent Label Override Indication | O | | ENUMERATED (true, ...) | Indicates that subcounters and their values of the precedent label applies in the same way except for the included subcounters. For included subcounters, new values shall apply. | +| Start End Indication | O | | ENUMERATED (start, end, ...) | <p>Used to indicate a range of values. If "start" is used for a label, the subsequent label should include this IE with "end".</p> <p>If included together with Distribution Bin type subcounter(s), it can be used to indicate a range of multi-dimensional values in the ascending order of numbers from Bin Z (if included), then from Bin Y (if included), then from Bin X (if included). In this case, information of a label with "start" should be identical to that of the subsequent label with "end", except Distribution Bin type subcounter(s) used.</p> <p>Otherwise (included together with subcounter other than Distribution Bin type subcounter), it can be used to indicate one-dimensional range of values in the ascending order, and information of a label with "start" should be identical to that of the subsequent label with "end", except only one subcounter.</p> | +| Min | O | | ENUMERATED (true, ...) | Minimum of the measured values over a granularity period. | + +| | | | | | +|--------------------------------|---|--|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Max | O | | ENUMERATED (true, ...) | Maximum of the measured values over a granularity period. | +| Avg | O | | ENUMERATED (true, ...) | Average of the measured values over a granularity period. | +| SSB Index | O | | INTEGER (1.. 65535, ...) | Represents the SSB subcounter | +| Non-GoB Beamforming Mode Index | O | | INTEGER (1.. 65535, ...) | Represents the Non- Grid of Beams (Non-GoB) beamforming mode subcounter [21]. The index is used for Non-GoB beamforming optimization for 5G mMIMO deployments. Each BF mode implies a vendor-specific proprietary Non-GoB BF algorithm that are not standardized [i.1], for which each E2 Node, who supports the Non-GoB beamforming optimization feature, provides the number of different Non-GoB BF mode(s) supported by its scheduler indexed from 1 to n. The AI/ML model for Non-GoB beamforming optimization is trained by data and measurements related to each BF mode and/or MIMO mode, for which the trained AI/ML model, based on collected data, configures the E2 Node with the best inferred Non-GoB BF mode index to be used for each UE, where such configuration could be done separately for the case of Single User- and/or Multi-user MIMO [21]. | +| MIMO Mode Index | O | | INTEGER (1..2, ...) | Represents the MIMO mode subcounter. Value = 1 means the SU (single-user) MIMO mode. Value 2 means the MU (multi-user) MIMO mode. | +| CGI | O | | 8.3.20 | Represents the subcounter for a specific cell, e.g., a neighboring cell of the subscribed E2 Node. | +| Beam ID | O | | 8.3.29 | Represents the beam subcounter, where the beam belongs to the subscribed E2 Node. An E2 Node level measurement can be obtained at beam-level using this subcounter. | + +### 8.3.12 Time Stamp + +This IE contains UTC time information in picosecond-level. In this version of specification, the value is rounded in millisecond. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|------------------------|---------------------------------------------------------------------------------------------------------| +| Time Stamp | M | | OCTET STRING (SIZE(8)) | Encoded in the same format as the 64-bit timestamp format as defined in clause 6 of IETF RFC 5905 [13]. | + +### 8.3.13 Void + +### 8.3.14 S-NSSAI + +This IE is defined in [12] clause 6.2.3.12. + +### 8.3.15 PLMN Identity + +This IE is defined in [12] clause 6.2.3.1. + +### 8.3.16 Void + +### 8.3.17 5QI + +This IE is defined in [12] clause 6.2.3.13. + +### 8.3.18 QCI + +This IE is defined in [12] clause 6.2.3.14. + +### 8.3.19 Void + +### 8.3.20 Cell Global ID + +This IE is defined in [12] clause 6.2.2.5. + +### 8.3.21 QFI + +This IE is defined in [12] clause 6.2.3.15. + +### 8.3.22 Test Condition Information + +This IE defines a test condition for identifying UEs. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------|-------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| CHOICE Test Condition Type | M | | | | +| >GBR | | | ENUMERATED (true, ...) | Identifies UEs with the GBR QoS flows or within the specified bitrate range. The definition of GBR QoS flow is in TS 23.501 [14]. | +| >AMBR | | | ENUMERATED (true, ...) | Identifies UEs with the Session-AMBR within the specified bitrate range. The definition of Session-AMBR is in TS 23.501 [14]. | +| >IsStat | | | ENUMERATED (true, ...) | This IE is not used in this version of specification. | +| >IsCatM | | | ENUMERATED (true, ...) | This IE is not used in this version of specification. | +| >DL RSRP | | | ENUMERATED (true, ...) | Identifies UEs with the latest reported DL RSRP measurement for this cell within the specified range. For EUTRAN, the definition of DL RSRP is in TS 36.214 [15]. For NR, the definition of DL RSRP is in TS 38.215 [16]. | +| >DL RSRQ | | | ENUMERATED (true, ...) | Identifies UEs with the latest reported DL RSRQ measurement for this cell within the specified range. For EUTRAN, the definition of DL RSRP is in TS 36.214 [15]. For NR, the definition of DL RSRQ is in TS 38.215 [16]. | +| >UL RSRP | | | ENUMERATED (true, ...) | Identifies UEs with the latest measured UL SRS-RSRP for this cell by the E2 Node within the specific range. The definition of UL SRS-RSRP is defined in TS 38.215 [16]. The mapping of measured quantity is described similarly to DL RSRP using the TS 38.133 [17] Table 10.1.6.1-1. | +| >CQI | | | ENUMERATED (true, ...) | Identifies UEs with the latest reported wideband CQI for this cell in the Layer 1 within the specific range. The definition of wideband CQI is defined in TS 38.214 [18]. | +| >5QI | | | ENUMERATED (true, ...) | Identifies UEs with the 5QI of QoS flows within the specified range. The definition of 5QI is in TS 23.501 [14]. | +| >QCI | | | ENUMERATED (true, ...) | Identifies UEs with the QCI of Service Data Flows within the specified range. The definition of QCI is in TS 23.203 [19]. | +| >S-NSSAI | | | ENUMERATED (true, ...) | Identifies UEs with the S-NSSAI [12] within the specified range. OCTET STRING of length 1 octet shall be provided for matching the SST value only. OCTET STRING of length 4 octets shall be provided for matching the SST + SD value. OCTET STRING of length 4 octets with the last 3 octets as 0xFFFFFFFF shall be provided if a S-NSSAI without SD value has to be explicitly matched. See 3GPP TS 23.003 [20] clause 28.4.2. | +| Test Condition | O | | ENUMERATED (equal, greaterthan, lessthan, contains, present, ...) | | +| Test Condition Value | O | | 8.3.23 | | + +### 8.3.23 Test Condition Value + +This IE defines the target value for a particular Test Condition Type IE element. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE <i>Test Value</i> | M | | | | +| >INTEGER | | | INTEGER | | +| >ENUMERATED | | | INTEGER | | +| >BOOLEAN | | | BOOLEAN | | +| >BIT STRING | | | BIT STRING | | +| >OCTET STRING | | | OCTET STRING | | +| >PRINTABLE STRING | | | PrintableString | | +| >REAL | | | REAL | | + +### 8.3.24 UE ID + +This IE is defined in [12] clause 6.2.2.6. + +### 8.3.25 Logical OR + +This IE indicates a logical “or” connection of the current condition to the next condition in a given sequence of conditions. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|------------------------|---------------------------------------------------------------------| +| Logical OR | M | | ENUMERATED (true, ...) | If set to “true”, logical connection to the next condition is “or”. | + +### 8.3.26 Bin Range Definition + +This IE defines the value range of bins for distribution type measurements. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------|----------|---------------------|-------------------------|------------------------------------------------------------------------------------------------| +| List of Bins for Distribution Bin X | | 1..<br><maxnoofBin> | | | +| >Bin Index | M | | INTEGER (1.. 65535, ..) | Index of a bin to be used when subscribed | +| >Start Value | M | | 8.3.27 | | +| >End Value | M | | 8.3.27 | | +| List of Bins for Distribution Bin Y | | 0..<br><maxnoofBin> | | Shall not be included for a distribution measurement type that doesn't use Distribution Bin Y. | +| >Bin Index | M | | INTEGER (1.. 65535, ..) | Index of a bin to be used when subscribed | +| >Start Value | M | | 8.3.27 | | +| >End Value | M | | 8.3.27 | | +| List of Bins for Distribution Bin Z | | 0..<br><maxnoofBin> | | Shall not be included for a distribution measurement type that doesn't use Distribution Bin Z. | +| >Bin Index | M | | INTEGER (1.. 65535, ..) | Index of a bin to be used when subscribed | +| >Start Value | M | | 8.3.27 | | +| >End Value | M | | 8.3.27 | | + +| Range bound | Explanation | +|-------------|------------------------------------------------------------------------------------------------| +| maxnoofBin | Maximum no. of bins that can be defined for a distribution type measurement. Value is <65535>. | + +### 8.3.27 Bin Range Value + +This IE defines either the start or end value of a bin for distribution type measurements. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE Bin Range Value | M | | | | +| >INTEGER | | | INTEGER | | +| >REAL | | | REAL | | + +### 8.3.28 Measured Value Reporting Condition + +This IE defines a test condition for reporting measured values when satisfied. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|-------------------------------------------------------------------|-----------------------| +| Test Condition | M | | ENUMERATED (equal, greaterthan, lessthan, contains, present, ...) | | +| Test Condition Value | M | | 8.3.23 | | + +### 8.3.29 Beam ID + +This IE is defined in [12] clause 6.2.2.16. + +### 8.3.30 Job ID + +This IE indicates the identifier of individual reports when using integrated level services. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------------------|-----------------------| +| Job ID | M | | INTEGER (1.. <i>maxnoofJobs</i> ) | | + +## 8.4 Information Element Abstract Syntax (with ASN.1) + +### 8.4.1 General + +E2SM-KPM ASN.1 definition conforms to ITU-T Rec. X.680 [5] and ITU-T Rec. X.681 [6]. + +Sub clause 8.4.2 presents the Abstract Syntax of the E2SM information elements to be carried within the E2AP [3] protocol messages with ASN.1. In case there is contradiction between the ASN.1 definition in this sub clause and the tabular format in sub clause 8.2 and 8.3, the ASN.1 shall take precedence, except for the definition of conditions for the presence of conditional elements, in which the tabular format shall take precedence. + +If an E2SM information element carried as an OCTET STRING in an E2AP [3] message that is not constructed as defined above is received, this shall be considered as Abstract Syntax Error, and the message shall be handled as defined for Abstract Syntax Error in clause 9. + +### 8.4.2 Information Element definitions + +``` +-- ASN1START +-- ***** +-- E2SM-KPM Information Element Definitions +-- ***** + +E2SM-KPM-IEs { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version2(2) e2sm(2) e2sm-KPMON-IEs (2)} + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +-- ***** +-- IEs +-- ***** + +IMPORTS + CGI, + FiveQI, + PLMNIdentity, + QCI, + QosFlowIdentifier, + RANfunction-Name, + RIC-Format-Type, + RIC-Style-Name, + RIC-Style-Type, +``` + +``` + + S-NSSAI, + UEID, + Beam-ID +FROM E2SM-COMMON-IEs; + +TimeStamp ::= OCTET STRING (SIZE(8)) + +BinIndex ::= INTEGER (1.. 65535, ...) + +BinRangeValue ::= CHOICE { + valueInt INTEGER, + valueReal REAL, + ... +} + +JobID ::= INTEGER (1.. 65535) + +GranularityPeriod ::= INTEGER (1.. 4294967295) + +LogicalOR ::= ENUMERATED {true, ...} + +MeasurementType ::= CHOICE { + measName MeasurementTypeName, + measID MeasurementTypeID, + ... +} + +MeasurementTypeName ::= PrintableString(SIZE(1.. 150, ...)) + +MeasurementTypeID ::= INTEGER (1.. 65536, ...) + +MeasurementLabel ::= SEQUENCE { + noLabel ENUMERATED {true, ...} OPTIONAL, + plmnID PLMNIdentity OPTIONAL, + sliceID S-NSSAI OPTIONAL, + fiveQI FiveQI OPTIONAL, + qFI QosFlowIdentifier OPTIONAL, + qCI QCI OPTIONAL, + qCImax QCI OPTIONAL, + qCImin QCI OPTIONAL, + aRPmax INTEGER (1.. 15, ...) OPTIONAL, + aRPmin INTEGER (1.. 15, ...) OPTIONAL, + bitrateRange INTEGER (1.. 65535, ...) OPTIONAL, + layerMU-MIMO INTEGER (1.. 65535, ...) OPTIONAL, + sUM ENUMERATED {true, ...} OPTIONAL, + distBinX INTEGER (1.. 65535, ...) OPTIONAL, + distBinY INTEGER (1.. 65535, ...) OPTIONAL, + +``` + +``` + +distBinZ INTEGER (1.. 65535, ...) OPTIONAL, +preLabelOverride ENUMERATED {true, ...} OPTIONAL, +startEndInd ENUMERATED {start, end, ...} OPTIONAL, +min ENUMERATED {true, ...} OPTIONAL, +max ENUMERATED {true, ...} OPTIONAL, +avg ENUMERATED {true, ...} OPTIONAL, +..., +ssbIndex INTEGER (1.. 65535, ...) OPTIONAL, +nonGoB-BFmode-Index INTEGER (1.. 65535, ...) OPTIONAL, +mIMO-mode-Index INTEGER (1.. 2, ...) OPTIONAL, +cellGlobalID CGI OPTIONAL, +beamID Beam-ID OPTIONAL +} + +``` + +``` + +TestCondInfo ::= SEQUENCE{ + testType TestCond-Type, + testExpr TestCond-Expression OPTIONAL, + testValue TestCond-Value OPTIONAL, + ... +} + +``` + +``` + +TestCond-Type ::= CHOICE{ + gBR ENUMERATED {true, ...}, + aMBR ENUMERATED {true, ...}, + isStat ENUMERATED {true, ...}, + isCatM ENUMERATED {true, ...}, + rSRP ENUMERATED {true, ...}, + rSRQ ENUMERATED {true, ...}, + ..., + ul-rSRP ENUMERATED {true, ...}, + cQI ENUMERATED {true, ...}, + fiveQI ENUMERATED {true, ...}, + qCI ENUMERATED {true, ...}, + sNSSAI ENUMERATED {true, ...} +} + +``` + +``` + +TestCond-Expression ::= ENUMERATED { + equal, + greaterthan, + lessthan, + contains, + present, + ... +} + +``` + +``` + +TestCond-Value ::= CHOICE{ + valueInt INTEGER, + valueEnum INTEGER, +} + +``` + +``` + +valueBool BOOLEAN, +valueBits BIT STRING, +valueOctS OCTET STRING, +valuePrts PrintableString, +..., +valueReal REAL +} + +MultiReportApproach ::= ENUMERATED { + single, + multiple, + ... +} + +-- ***** +-- Lists +-- ***** + +maxnoofCells INTEGER ::= 16384 +maxnoofRICStyles INTEGER ::= 63 +maxnoofMeasurementInfo INTEGER ::= 65535 +maxnoofLabelInfo INTEGER ::= 2147483647 +maxnoofMeasurementRecord INTEGER ::= 65535 +maxnoofMeasurementValue INTEGER ::= 2147483647 +maxnoofConditionInfo INTEGER ::= 32768 +maxnoofUEID INTEGER ::= 65535 +maxnoofConditionInfoPerSub INTEGER ::= 32768 +maxnoofUEIDPerSub INTEGER ::= 65535 +maxnoofUEMeasReport INTEGER ::= 65535 +maxnoofBin INTEGER ::= 65535 +maxnoofJobs INTEGER ::= 65535 + +BinRangeDefinition ::= SEQUENCE { + binRangeListX BinRangeList, + binRangeListY BinRangeList OPTIONAL -- This IE shall not be present for a distribution measurement type that doesn't use Distribution Bin Y --, + binRangeListZ BinRangeList OPTIONAL -- This IE shall not be present for a distribution measurement type that doesn't use Distribution Bin Z --, + ... +} + +BinRangeList ::= SEQUENCE (SIZE(1..maxnoofBin)) OF BinRangeItem + +BinRangeItem ::= SEQUENCE { + binIndex BinIndex, + startValue BinRangeValue, + endValue BinRangeValue, + ... + +``` + +``` + +} + +DistMeasurementBinRangeList ::= SEQUENCE (SIZE(1..maxnoofMeasurementInfo)) OF DistMeasurementBinRangeItem + +DistMeasurementBinRangeItem ::= SEQUENCE { + measType MeasurementType, + binRangeDef BinRangeDefinition, + ... +} + +MeasurementInfoList ::= SEQUENCE (SIZE(1..maxnoofMeasurementInfo)) OF MeasurementInfoItem + +MeasurementInfoItem ::= SEQUENCE { + measType MeasurementType, + labelInfoList LabelInfoList, + ..., + matchCondReportList MatchCondReportList OPTIONAL +} + +LabelInfoList ::= SEQUENCE (SIZE(1..maxnoofLabelInfo)) OF LabelInfoItem + +LabelInfoItem ::= SEQUENCE { + measLabel MeasurementLabel, + ... +} + +MatchCondReportList ::= SEQUENCE (SIZE(1..maxnoofConditionInfo)) OF MatchCondReportItem + +MatchCondReportItem ::= SEQUENCE { + measValueReportCond MeasValueReportCond, + logicalOR LogicalOR OPTIONAL, + ... +} + +MeasValueReportCond ::= SEQUENCE { + testExpr MeasValueTestCond-Expression, + testValue TestCond-Value, + ... +} + +MeasValueTestCond-Expression ::= ENUMERATED { + equal, + greaterthan, + lessthan, + contains, + present, + ... +} + +``` + +``` + +} + +MeasurementData ::= SEQUENCE (SIZE(1..maxnoofMeasurementRecord)) OF MeasurementDataItem + +MeasurementDataItem ::= SEQUENCE { + measRecord MeasurementRecord, + incompleteFlag ENUMERATED {true, ...} OPTIONAL, + ... +} + +MeasurementRecord ::= SEQUENCE (SIZE(1..maxnoofMeasurementValue)) OF MeasurementRecordItem + +MeasurementRecordItem ::= CHOICE { + integer INTEGER (0.. 4294967295), + real REAL, + noValue NULL, + ..., + notSatisfied NULL +} + +MeasurementInfo-Action-List ::= SEQUENCE (SIZE(1..maxnoofMeasurementInfo)) OF MeasurementInfo-Action-Item + +MeasurementInfo-Action-Item ::= SEQUENCE { + measName MeasurementTypeName, + measID MeasurementTypeID OPTIONAL, + ..., + binRangeDef BinRangeDefinition OPTIONAL +} + +MeasurementCondList ::= SEQUENCE (SIZE(1..maxnoofMeasurementInfo)) OF MeasurementCondItem + +MeasurementCondItem ::= SEQUENCE { + measType MeasurementType, + matchingCond MatchingCondList, + ..., + binRangeDef BinRangeDefinition OPTIONAL +} + +MeasurementCondUEidList ::= SEQUENCE (SIZE(1..maxnoofMeasurementInfo)) OF MeasurementCondUEidItem + +MeasurementCondUEidItem ::= SEQUENCE { + measType MeasurementType, + matchingCond MatchingCondList, + matchingUEidList MatchingUEidList OPTIONAL, + ..., + matchingUEidPerGP MatchingUEidPerGP OPTIONAL +} + +``` + +``` + +MatchingCondList ::= SEQUENCE (SIZE(1..maxnoofConditionInfo)) OF MatchingCondItem + +MatchingCondItem ::= SEQUENCE { + matchingCondChoice MatchingCondItem-Choice, + logicalOR LogicalOR OPTIONAL, + ... +} + +MatchingCondItem-Choice ::= CHOICE{ + measLabel MeasurementLabel, + testCondInfo TestCondInfo, + ... +} + +MatchingUEidList ::= SEQUENCE (SIZE(1..maxnoofUEID)) OF MatchingUEidItem + +MatchingUEidItem ::= SEQUENCE{ + ueID UEID, + ... +} + +MatchingUEidPerGP ::= SEQUENCE (SIZE(1..maxnoofMeasurementRecord)) OF MatchingUEidPerGP-Item + +MatchingUEidPerGP-Item ::= SEQUENCE{ + matchedPerGP CHOICE{ + noUEmatched ENUMERATED {true, ...}, + oneOrMoreUEmatched MatchingUEidList-PerGP, + ... + }, + ... +} + +MatchingUEidList-PerGP ::= SEQUENCE (SIZE(1..maxnoofUEID)) OF MatchingUEidItem-PerGP + +MatchingUEidItem-PerGP ::= SEQUENCE{ + ueID UEID, + ... +} + +MatchingUeCondPerSubList ::= SEQUENCE (SIZE(1..maxnoofConditionInfoPerSub)) OF MatchingUeCondPerSubItem + +MatchingUeCondPerSubItem ::= SEQUENCE{ + testCondInfo TestCondInfo, + ..., + logicalOR LogicalOR OPTIONAL +} + +``` + +``` + +MatchingUEidPerSubList ::= SEQUENCE (SIZE(2..maxnoofUEIDPerSub)) OF MatchingUEidPerSubItem + +MatchingUEidPerSubItem ::= SEQUENCE{ + ueID UEID, + ... +} + +MultiReportActionDefinitionList ::= SEQUENCE (SIZE(1..maxnoofJobs)) OF MultiReportActionDefinitionItem + +MultiReportActionDefinitionItem ::=SEQUENCE { + jobID JobID, + jobActionDefinition E2SM-KPM-ActionDefinition OPTIONAL, + jobCellGlobalID CGI OPTIONAL, + jobUEID UEID OPTIONAL, + jobMatchingUEidList MatchingUEidPerSubList OPTIONAL, + ... +} + +MultiReportIndicationMessageList ::= SEQUENCE (SIZE(1..maxnoofJobs)) OF MultiReportIndicationMessageItem + +MultiReportIndicationMessageItem ::=SEQUENCE { + jobID JobID, + indicationMessage E2SM-KPM-IndicationMessage, + ... +} + +UEMeasurementReportList ::= SEQUENCE (SIZE(1..maxnoofUEMeasReport)) OF UEMeasurementReportItem + +UEMeasurementReportItem ::= SEQUENCE{ + ueID UEID, + measReport E2SM-KPM-IndicationMessage-Format1, + ... +} + +-- ***** +-- E2SM-KPM Service Model IEs +-- ***** + +-- ***** +-- Event Trigger Definition OCTET STRING contents +-- ***** + +E2SM-KPM-EventTriggerDefinition ::= SEQUENCE{ + +``` + +``` + +eventDefinition-formats CHOICE{ + eventDefinition-Format1 E2SM-KPM-EventTriggerDefinition-Format1, + ... +}, +... +} + +``` + +``` + +E2SM-KPM-EventTriggerDefinition-Format1 ::= SEQUENCE{ + reportingPeriod INTEGER (1.. 4294967295), + ... +} + +``` + +``` + + +-- Action Definition OCTET STRING contents + + +``` + +``` + +E2SM-KPM-ActionDefinition ::= SEQUENCE{ + ric-Style-Type RIC-Style-Type, + actionDefinition-formats CHOICE{ + actionDefinition-Format1 E2SM-KPM-ActionDefinition-Format1, + actionDefinition-Format2 E2SM-KPM-ActionDefinition-Format2, + actionDefinition-Format3 E2SM-KPM-ActionDefinition-Format3, + ..., + actionDefinition-Format4 E2SM-KPM-ActionDefinition-Format4, + actionDefinition-Format5 E2SM-KPM-ActionDefinition-Format5, + actionDefinition-Format255 E2SM-KPM-ActionDefinition-Format255 + }, + ... +} + +``` + +``` + +E2SM-KPM-ActionDefinition-Format1 ::= SEQUENCE { + measInfoList MeasurementInfoList, + granulPeriod GranularityPeriod, + cellGlobalID CGI OPTIONAL, + ..., + distMeasBinRangeInfo DistMeasurementBinRangeList OPTIONAL +} + +``` + +``` + +E2SM-KPM-ActionDefinition-Format2 ::= SEQUENCE { + ueID UEID, + subscriptInfo E2SM-KPM-ActionDefinition-Format1, + ... +} + +``` + +``` + +E2SM-KPM-ActionDefinition-Format3 ::= SEQUENCE { + measCondList MeasurementCondList, + granulPeriod GranularityPeriod, + cellGlobalID CGI OPTIONAL, + +``` + +``` + + ... +} + +E2SM-KPM-ActionDefinition-Format4 ::= SEQUENCE { + matchingUeCondList MatchingUeCondPerSubList, + subscriptionInfo E2SM-KPM-ActionDefinition-Format1, + ... +} + +E2SM-KPM-ActionDefinition-Format5 ::= SEQUENCE { + matchingUEidList MatchingUEidPerSubList, + subscriptionInfo E2SM-KPM-ActionDefinition-Format1, + ... +} + +E2SM-KPM-ActionDefinition-Format255 ::= SEQUENCE { + multiReportActionDefinitionList MultiReportActionDefinitionList, + multiReportApproach MultiReportApproach, + commonActionDefinition E2SM-KPM-ActionDefinition OPTIONAL, + ... +} + +-- +-- Indication Header OCTET STRING contents +-- + +E2SM-KPM-IndicationHeader ::= SEQUENCE{ + indicationHeader-formats CHOICE{ + indicationHeader-Format1 E2SM-KPM-IndicationHeader-Format1, + ... + }, + ... +} + +E2SM-KPM-IndicationHeader-Format1 ::= SEQUENCE{ + colletStartTime TimeStamp, + fileFormatversion PrintableString (SIZE (0..15), ...) OPTIONAL, + senderName PrintableString (SIZE (0..400), ...) OPTIONAL, + senderType PrintableString (SIZE (0..8), ...) OPTIONAL, + vendorName PrintableString (SIZE (0..32), ...) OPTIONAL, + ... +} + +-- +-- Indication Message OCTET STRING contents +-- + +E2SM-KPM-IndicationMessage ::= SEQUENCE{ + +``` + +``` + +indicationMessage-formats CHOICE{ + indicationMessage-Format1 E2SM-KPM-IndicationMessage-Format1, + indicationMessage-Format2 E2SM-KPM-IndicationMessage-Format2, + ..., + indicationMessage-Format3 E2SM-KPM-IndicationMessage-Format3, + indicationMessage-Format255 E2SM-KPM-IndicationMessage-Format255 +}, +..., +jobID JobID OPTIONAL +} + +E2SM-KPM-IndicationMessage-Format1 ::= SEQUENCE { + measData MeasurementData, + measInfoList MeasurementInfoList OPTIONAL, + granulPeriod GranularityPeriod OPTIONAL, + ... +} + +E2SM-KPM-IndicationMessage-Format2 ::= SEQUENCE { + measData MeasurementData, + measCondUEidList MeasurementCondUEidList, + granulPeriod GranularityPeriod OPTIONAL, + ... +} + +E2SM-KPM-IndicationMessage-Format3 ::= SEQUENCE { + ueMeasReportList UEMeasurementReportList, + ... +} + +E2SM-KPM-IndicationMessage-Format255 ::= SEQUENCE { + multiReportIndicationMessageList MultiReportIndicationMessageList, + ... +} + +-- ***** +-- RAN Function Definition OCTET STRING contents +-- ***** + +E2SM-KPM-RANfunction-Description ::= SEQUENCE{ + ranFunction-Name RANfunction-Name, + ric-EventTriggerStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF RIC-EventTriggerStyle-Item OPTIONAL, + ric-ReportStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF RIC-ReportStyle-Item OPTIONAL, + ..., + ric-IntegratedReportStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF RIC-IntegratedReportStyle-Item OPTIONAL +} + +``` + +``` + +RIC-EventTriggerStyle-Item ::= SEQUENCE{ + ric-EventTriggerStyle-Type RIC-Style-Type, + ric-EventTriggerStyle-Name RIC-Style-Name, + ric-EventTriggerFormat-Type RIC-Format-Type, + ... +} + +RIC-ReportStyle-Item ::= SEQUENCE{ + ric-ReportStyle-Type RIC-Style-Type, + ric-ReportStyle-Name RIC-Style-Name, + ric-ActionFormat-Type RIC-Format-Type, + measInfo-Action-List MeasurementInfo-Action-List, + ric-IndicationHeaderFormat-Type RIC-Format-Type, + ric-IndicationMessageFormat-Type RIC-Format-Type, + ... +} + +RIC-IntegratedReportStyle-Item ::= SEQUENCE{ + ric-ReportStyle-Type RIC-Style-Type, + ric-ReportStyle-Name RIC-Style-Name, + ric-ActionFormat-Type RIC-Format-Type, + ric-IndicationHeaderFormat-Type RIC-Format-Type, + ric-IndicationMessageFormat-Type RIC-Format-Type, + ric-FundamentalLevelReportStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF RIC-FundamentalLevelReportStyle-Item OPTIONAL, + ric-SingleReportingApproachSupport ENUMERATED{true,...} OPTIONAL, + ric-MultipleReportingApproachSupport ENUMERATED{true,...} OPTIONAL, + ric-CommonActionDefinitionSupport ENUMERATED{true,...} OPTIONAL, + ... +} + +RIC-FundamentalLevelReportStyle-Item ::= SEQUENCE{ + ric-ReportStyle-Type RIC-Style-Type, + jobSpecificActionDefinitionSupport ENUMERATED{true,...} OPTIONAL, + jobSpecificCellGlobalIDSupport ENUMERATED{true,...} OPTIONAL, + jobSpecificUEIDSupport ENUMERATED{true,...} OPTIONAL, + jobSpecificMatchingUEidListSupport ENUMERATED{true,...} OPTIONAL, + ... +} + +END + +-- ASN1STOP + +``` + +# --- 9 Handling of Unknown, Unforeseen and Erroneous Protocol Data + +clause 10 of TS 36.413 [13] is applicable for the purposes of the present document. + +# Annex A (normative or informative): Further information on RAN Function Network KPM Monitor + +## A.1 Background Information + +The RAN function “Key Performance Measurement” is used to provide RIC Service exposure of the performance measurement logical function of the E2 Nodes. Based on the O-RAN deployment architecture, available measurements could be different. Figure A.1-1 shows the target deployment architecture for E2SM-KPM. + +![Figure A.1-1: E2SM-KPM Architecture. The diagram illustrates two network architectures: 'MR-DC with EPC' and '5GC connection'. In the 'MR-DC with EPC' architecture, an EPC (Evolved Packet Core) is connected to an O-eNB (E2 Node) via S1-C (control) and S1-U (user plane). The O-eNB is connected to a Near-Real Time RIC (Non-Real Time RIC) via E2 interfaces. The Near-Real Time RIC is connected to O-CU-CP and O-CU-UP (E2 Nodes) via E2 interfaces. The O-CU-CP and O-CU-UP are connected to an O-DU (E2 Node) via F1-C and F1-U interfaces. The O-DU is connected to the O-CU-CP and O-CU-UP via X2-C and X2-U interfaces. In the '5GC connection' architecture, a 5GC (5G Core) is connected to a Near-Real Time RIC via N2 (control) and N3 (user plane). The Near-Real Time RIC is connected to O-CU-CP and O-CU-UP (E2 Nodes) via E2 interfaces. The O-CU-CP and O-CU-UP are connected to an O-DU (E2 Node) via F1-C and F1-U interfaces. The O-DU is connected to the O-CU-CP and O-CU-UP via E1 interfaces.](3278a8a64af0266447dbdb59e9016bbc_img.jpg) + +Figure A.1-1: E2SM-KPM Architecture. The diagram illustrates two network architectures: 'MR-DC with EPC' and '5GC connection'. In the 'MR-DC with EPC' architecture, an EPC (Evolved Packet Core) is connected to an O-eNB (E2 Node) via S1-C (control) and S1-U (user plane). The O-eNB is connected to a Near-Real Time RIC (Non-Real Time RIC) via E2 interfaces. The Near-Real Time RIC is connected to O-CU-CP and O-CU-UP (E2 Nodes) via E2 interfaces. The O-CU-CP and O-CU-UP are connected to an O-DU (E2 Node) via F1-C and F1-U interfaces. The O-DU is connected to the O-CU-CP and O-CU-UP via X2-C and X2-U interfaces. In the '5GC connection' architecture, a 5GC (5G Core) is connected to a Near-Real Time RIC via N2 (control) and N3 (user plane). The Near-Real Time RIC is connected to O-CU-CP and O-CU-UP (E2 Nodes) via E2 interfaces. The O-CU-CP and O-CU-UP are connected to an O-DU (E2 Node) via F1-C and F1-U interfaces. The O-DU is connected to the O-CU-CP and O-CU-UP via E1 interfaces. + +Figure + +A.1-1 E2SM-KPM Architecture + +For each logical function the E2 Node shall use the RAN Function Definition IE to declare the list of available measurements and a set of supported RIC Services (**REPORT**). + +# Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2020.01.29 | v01.00 | Initial version | +| 2020.12.16 | 02.00.00 | Adopt INTEL.AO's CR-0001 and CR-0002 for E2SM-KPM with cleaning up old texts and ASN.1 in v01.00 | +| 2021.02.24 | 02.00.01 | Adopt ATT.AO's CR-0001 for UE-level measurements subscription and retrieval | +| 2021.03.03 | 02.00.02 | Adopt CSP.AO's CR-0001 for Incomplete Flag | +| 2021.03.30 | 02.00.03 | Adopt INTEL's CR-0003 for clean-up | +| 2021.06.09 | 02.00.04 | Adopt (1) INT's CR-0006; (2) INT's CR-0008; (3) RSYS's CR-0004 | +| 2021.07.09 | 02.00.05 | Adopt (1) INT's CR-0009; (2) NEU.AO's CR-0001 | +| 2021.08.10 | 02.00 | New features: UE-level measurements subscription and retrieval, Incomplete Flag, clean up from v01. | +| 2021.10.13 | 02.01.00 | Adopt (1) INTEL.AO's CR-0011; (2) RSYS.AO's CR-0002 | +| 2021.10.27 | 02.01.01 | Adopt KDDI's CR-0001. | +| 2021.11.22 | 02.01.02 | Editorial Updates based on review comments during WG3 approval process | +| 2022.02.07 | 02.01 | New features: Add Cell Global ID description new Report Service Styles 4 and 5 introduced for flexible reporting of UE level measurements, enhancing conversion rule from measurements parameter defined in 3GPP and O-RAN, and added new O-RAN specific parameters | +| 2022.03.23 | 02.02.00 | Adopt (1) TIM.AO's CR-0003; (2) CMCC.AO's CR-0001; (3) CMCC.AO's CR-0002 | +| 2022.04.14 | 02.02 | New features: Add new parameters for better supporting UE grouping with Format 3, add new test condition types 5QI and QCI for Report Service Style Type 3 and 4, and add S-NSSAI for new test condition. | +| 2022.05.11 | 02.02.01 | Adopt (1) INT's CR-0015; (2) INT's CR-0016; (3) INT's CR-0017 | +| 2022.07.20 | 02.02.02 | Adopt INT's CR-0022 | +| 2022.07.24 | 02.02.03 | Aligned to new template | +| 2022.08.09 | 02.03 | New features: Add new Report Service Styles 4 and 5 introduced for flexible reporting of UE level measurements, Enhancing conversion rule from measurements parameter defined in 3GPP and O-RAN adding new O-RAN specific parameters clarifying CGI handling in Action Definition Formats, UL-RSRP and CQI for signal quality based UE grouping in Format 3, extend new test condition types for Report Service Style Type 3 and 4, adding Slice ID measurement label, Adding "Logical OR" into UE filtering conditions, Indication Message Format 2 for REPORT Style 3, bin range definition of distribution type measurements, Support mMIMO non-GoB measurements | +| 2022.11.09 | 02.03.01 | Adopt (1) INT's CR-0024; (2) INT's CR-0027 | +| 2022.11.20 | 02.03.02 | Editorial changes reflecting comments received during WG3 approval process | +| 2022.11.25 | 03.00 | New features: Correction for E2SM-KPM Timestamp, Correction for mMIMO Non-GoB BF optimization | +| 2023.06.30 | 03.00.01 | Adopt (1) NOK.AO's CR-0002; (2) MAV.AO's CR-0013 | +| 2023.07.26 | 03.00.02 | Editorial changes reflecting comments received during WG3 approval process | +| 2023.07.26 | 03.00.03 | Further Editorial changes reflecting comments received during WG3 approval process | +| 2023.07.29 | 04.00 | New features: Add support mMIMO bMRO measurements and reporting, DL total number of scheduled time slots | +| 2024.03.05 | 04.00.01 | Adopt (1) SAM.AO's CR-0002; (2) NOK's CR-0003; (3) SAM's CR-0004 (4)SAM's CR-0006 (5) NOK.AO CR-0004 (6) SAM's CR-0007 | +| 2024.03.22 | 04.00.02 | Adopt SAM's CR-0003 | +| 2024.03.27 | 04.00.03 | Editorial changes reflecting comments received during WG3 approval process | +| 2024.04.08 | 05.00 | New feature: Add Multi-Cell support | +| 2024.11.21 | 05.00.01 | Adopt (1) SAM's CR-0006; (2) SAM's CR-0009; (3) NEC's CR-033; (4) LGE's CR-0001; (5) SAM.AO's CR-0010 | +| 2024.11.26 | 05.00.02 | Editorial changes reflecting comments received during WG3 review process | +| 2024.11.27 | 05.00.03 | Editorial changes reflecting a comment received during WG3 review process | +| 2024.12.06 | 06.00 | New feature: Add DL and UL Transmitted Data Volume for MAC SDU | \ No newline at end of file diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/0e2c8aaa6fec3d343cca5bd8df15556c_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/0e2c8aaa6fec3d343cca5bd8df15556c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7f6f92017bef849826757a80798f3b6d16d60f47 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/0e2c8aaa6fec3d343cca5bd8df15556c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f865d428dfffbd094e2b463691f6707ee75887069d4c65fc7fff9afc196af3fc +size 4344 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/2c8d19184ed361aee19db6935ff867c0_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/2c8d19184ed361aee19db6935ff867c0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9b9ddab92b8aba848b310e8ee31671a3120f685e --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/2c8d19184ed361aee19db6935ff867c0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:94ea6e8073591c5620c3f55460edf1422134cc7b114c57f821d2ff42f9647562 +size 4293 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/80b1bcf16093993a2a19166489a2ed86_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/80b1bcf16093993a2a19166489a2ed86_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3a165bd5c0cb3ec793e6995c390fb38f9dfd8dc9 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/80b1bcf16093993a2a19166489a2ed86_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:652f933e561648e2bd49e7d3f7558fa19c4b47fc29aa833a7b2518bbabf86294 +size 4255 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/8f35f7ef412c6c14a56337e34de812ae_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/8f35f7ef412c6c14a56337e34de812ae_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b407bb4297cc01f05ede983a583a4ba68cebec3c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/8f35f7ef412c6c14a56337e34de812ae_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:75c103140f1bacf369ec2efda5a8bcd5867790228c62e824aabf21ac34fc7e24 +size 4288 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/c9983eb6d0be3ae87143458fa53fa4af_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/c9983eb6d0be3ae87143458fa53fa4af_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ccd2c1a429f3492885878228012fe7b66dfda5da --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/c9983eb6d0be3ae87143458fa53fa4af_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fa8f53941a7845ebac5735a0d1f88e85ea2f0b17fb49c2628b15121674782332 +size 4285 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/d29c37617ac665797b5c7cc931fb7249_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/d29c37617ac665797b5c7cc931fb7249_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4ff3cce4e3eea749213205dee7a4c81880b23d7d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/d29c37617ac665797b5c7cc931fb7249_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ed2b0ebe0c0e92e866d582a14ad337851f144ccbb60c67f00678b503932d633 +size 4251 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/f06aaf2ba92a82d372a0ab5968601cc9_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/f06aaf2ba92a82d372a0ab5968601cc9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..891c38681a4bc4115c2fc54edc3363221a7fef79 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/f06aaf2ba92a82d372a0ab5968601cc9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b25da02ff0a750c8395e9b76632b775af75cb781ba888a00bc371d8937f7b251 +size 4288 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/f99a45066596728f37fb7e96edbfa4da_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/f99a45066596728f37fb7e96edbfa4da_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..05bef634f69c6d10a00e56416a05e19f698c3c12 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/f99a45066596728f37fb7e96edbfa4da_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c0f829f767a86ac4dbdfc895cac37b0334f3c1b624b9e7bb870a8448f1562178 +size 4305 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/raw.md b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..36754d97c8d351d466f8a46891a31059daf76e15 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00/raw.md @@ -0,0 +1,1993 @@ + + +# --- **O-RAN Work Group 3 (Near-RT RIC and E2 Interface)****E2 Service Model (E2SM), Lower Layers Control** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|--------------------------------------------------------------------------------------------|----| +| Contents ..... | 2 | +| List of tables ..... | 4 | +| Foreword..... | 5 | +| Modal verbs terminology ..... | 5 | +| 1 Scope ..... | 6 | +| 2 References ..... | 6 | +| 2.1 Normative references ..... | 6 | +| 2.2 Informative references ..... | 6 | +| 3 Definition of terms, symbols, and abbreviations ..... | 7 | +| 3.1 Terms ..... | 7 | +| 3.2 Symbols..... | 7 | +| 3.3 Abbreviations ..... | 7 | +| 4 General ..... | 7 | +| 4.1 Procedure specification principles ..... | 7 | +| 4.2 Forwards and backwards compatibility ..... | 7 | +| 4.3 Specification notations ..... | 7 | +| 5 E2SM services..... | 8 | +| 6 RAN function service model description ..... | 8 | +| 6.1 RAN function overview ..... | 8 | +| 6.2 RAN function exposure services ..... | 9 | +| 6.2.1 REPORT service ..... | 9 | +| 6.2.2 INSERT service..... | 9 | +| 6.2.3 CONTROL service..... | 9 | +| 6.2.4 POLICY service ..... | 9 | +| 6.2.5 QUERY service..... | 9 | +| 6.3 REPORT service description ..... | 9 | +| 6.4 INSERT service description ..... | 9 | +| 6.5 CONTROL service description..... | 10 | +| 6.6 POLICY service description..... | 10 | +| 6.7 QUERY service description..... | 10 | +| 7 RAN function description ..... | 10 | +| 7.1 RAN function definition ..... | 10 | +| 7.2 RAN function name ..... | 10 | +| 7.3 Event trigger definition styles ..... | 11 | +| 7.3.1 RIC <i>Event Trigger Definition</i> IE style list ..... | 11 | +| 7.3.2 RIC <i>Event Trigger Definition</i> IE style 1: Lower Layers Information Event ..... | 11 | +| 7.3.3 RIC Event trigger definition IE style 2: Periodic ..... | 11 | +| 7.4 Supported RIC REPORT services ..... | 11 | +| 7.4.1 REPORT service style list..... | 11 | +| 7.4.2 REPORT service style 1: Lower layers information copy ..... | 11 | +| 7.4.3 REPORT Service Style 2: Lower layers measurements ..... | 12 | +| 7.5 Supported RIC INSERT services..... | 13 | +| 7.6 Supported RIC CONTROL services..... | 13 | +| 7.6.1 CONTROL service style types..... | 13 | +| 7.6.2 CONTROL service style 1: Logical channels handling control ..... | 13 | +| 7.6.3 CONTROL Service Style 2: Scheduling Parameters Control..... | 14 | +| 7.7 Supported RIC POLICY services ..... | 15 | +| 7.8 Supported RIC QUERY services..... | 15 | +| 7.9 Supported RIC service styles and E2SM IE formats ..... | 15 | + +| | | | +|--------|------------------------------------------------------------------|----| +| 8 | Elements for E2SM service model..... | 16 | +| 8.1 | General..... | 16 | +| 8.2 | Message functional definition and content ..... | 16 | +| 8.2.1 | Messages for RIC Functional procedures ..... | 16 | +| 8.2.2 | Messages for RIC global procedures ..... | 20 | +| 8.3 | Information Element definitions ..... | 22 | +| 8.3.1 | General ..... | 22 | +| 8.3.2 | RAN Function Name..... | 22 | +| 8.3.3 | RIC Style Type..... | 22 | +| 8.3.4 | RIC Style Name ..... | 22 | +| 8.3.5 | RIC Format Type ..... | 22 | +| 8.3.6 | Control Action ID..... | 23 | +| 8.3.7 | Control Action Name ..... | 23 | +| 8.3.8 | UE ID ..... | 23 | +| 8.3.9 | Event Trigger Condition ID ..... | 23 | +| 8.3.10 | Event Trigger ID for UE ..... | 23 | +| 8.3.11 | Logical OR ..... | 23 | +| 8.3.12 | Event Trigger UE Information ..... | 23 | +| 8.3.13 | Group of UEs ..... | 24 | +| 8.3.14 | Cell Global ID ..... | 24 | +| 8.3.15 | Lower Layers Information Type ..... | 24 | +| 8.3.16 | Lower Layers Measurement Type..... | 24 | +| 8.3.17 | Slot Information ..... | 25 | +| 8.3.18 | Slot Time Stamp..... | 25 | +| 8.3.19 | SRS..... | 25 | +| 8.3.20 | CSI..... | 27 | +| 8.3.21 | DL RLC Buffer Status..... | 28 | +| 8.3.22 | DL PDCP Buffer Status ..... | 29 | +| 8.3.23 | DL HARQ Statistics..... | 30 | +| 8.3.24 | Received Timestamp..... | 31 | +| 8.3.25 | Logical Channel Handling Control ..... | 31 | +| 8.3.26 | DL Scheduling Control ..... | 32 | +| 8.3.27 | DL Scheduling Control Outcome..... | 37 | +| 8.4 | Information Element abstract syntax (with ASN.1) ..... | 40 | +| 8.4.1 | General ..... | 40 | +| 8.4.2 | Information Element Definitions ..... | 40 | +| 8.5 | Message transfer syntax..... | 49 | +| 9 | Handling of unknown, unforeseen and erroneous protocol data..... | 49 | +| | Annex (informative): Change history..... | 49 | + +# --- List of tables + +| | | +|-----------------------------------------------------------------------------------------------------------|----| +| Table 5-1: Relationship between RAN Function specific E2AP Information elements and E2AP Procedures ..... | 8 | +| Table 7.9-1: Summary of the E2SM IE Formats defined to support RIC Event Trigger Styles ..... | 15 | +| Table 7.9-2: Summary of the E2SM IE Formats defined to support RIC Service Styles..... | 15 | +| Table 7.9-3: Summary of the E2SM IE Formats defined to support RIC Service Styles..... | 15 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG3 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document describes the E2 service model (E2SM) for the Near RT RIC Lower Layers Control interaction covering layers L1 and L2 interactions. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18, or the latest 3GPP release prior to Release 18 that includes that document. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN.WG3.TS.E2GAP: “O-RAN E2 General Aspects and Principles (E2GAP)”. +- [2] O-RAN.WG1.TS.OAD: "O-RAN Architecture Description". +- [3] O-RAN.WG3.TS.E2AP: “O-RAN E2 Application Protocol (E2AP)”. +- [4] O-RAN.WG3.TS.E2SM: “O-RAN E2 Service Model (E2SM)”. +- [5] 3GPP TS 38.211: “NR; Physical channels and modulation”. +- [6] 3GPP TS 38.213: “NR; Physical layer procedures for control”. +- [7] IETF RFC 5905 (2010-06): “Network Time Protocol Version 4: Protocol and Algorithms Specification”. +- [8] O-RAN.WG4.TS.CUS: “O-RAN Control, User and Synchronization Plane Specification”. +- [9] 3GPP TS 38.331: “NR; Radio Resource Control (RRC) Protocol Specification”. +- [10] 3GPP TS 25.321: “Medium Access Control (MAC) protocol specification”. +- [11] 3GPP TS 37.483: “E1 Application Protocol (E1AP)”. +- [12] 3GPP TS 38.323: “NR; Packet Data Convergence Protocol (PDCP) specification”. +- [13] 3GPP TS 38.214: "NR; Physical layer procedures for data". +- [14] 3GPP TS 38.212: “NR; Multiplexing and channel coding”. +- [15] Recommendation ITU-T X.680 (2002-07): "Information technology – Abstract Syntax Notation One (ASN.1): Specification of basic notation". +- [16] Recommendation ITU-T X.681 (2002-07): "Information technology – Abstract Syntax Notation One (ASN.1): Information object specification". +- [17] Recommendation ITU-T X.691 (2002-07): "Information technology - ASN.1 encoding rules - Specification of Packed Encoding Rules (PER) ". +- [18] 3GPP TS 36.413: “E-UTRAN; S1 Application Protocol (S1AP)”. + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18, or the latest 3GPP release prior to Release 18 that includes that document. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +[i.1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. + +# --- 3 Definition of terms, symbols, and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in 3GPP TR 21.905 [i.1], O-RAN WG3.TS.E2GAP [1], O-RAN WG1.TS.OAD [2]. + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [i.1], O-RAN WG3.TS.E2GAP [1], O-RAN WG1.TS.OAD [2], and the following apply. + +| | | +|-----|----------------------------| +| HOL | Head of Line | +| LLI | Lower Layers Information | +| PDB | Packet Delay Budget | +| SMG | Spatial Multiplexing Group | +| SPS | Semi Persistent Scheduling | + +# --- 4 General + +## 4.1 Procedure specification principles + +The procedure specification principles defined in O-RAN WG3.TS.E2AP [3] clause 4 shall apply. + +## 4.2 Forwards and backwards compatibility + +The forwards and backwards compatibility of the E2 interface uses the forward and backwards compatibility compatibilities offered by the O-RAN WG3.TS.E2AP [3] protocol. + +## 4.3 Specification notations + +For the purposes of the present document, the following notations apply: + +| | | +|---------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Service | when referring to a Service in the specification the <b>SERVICE NAME</b> is written with upper case characters and in bold followed by the word "service", e.g. <b>REPORT</b> service. | +|---------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Procedure | When referring to an elementary procedure in the specification the Procedure Name is written with the first letters in each word in upper case characters followed by the word "procedure", e.g. Handover Preparation procedure. | +| Message | When referring to a message in the specification the MESSAGE NAME is written with all letters in upper case characters followed by the word "message", e.g. HANDOVER REQUEST message. | +| IE | When referring to an information element (IE) in the specification the <i>Information Element Name</i> is written with the first letters in each word in upper case characters and all letters in Italic font followed by the abbreviation "IE", e.g. <i>Event Trigger Condition ID</i> IE. | +| Value of an IE | When referring to the value of an information element (IE) in the specification the "Value" is written as it is specified in the specification enclosed by quotation marks, e.g. "Value". | + +# 5 E2SM services + +As defined in O-RAN WG3.TS.E2GAP [1], a given RAN Function offers a set of services to be exposed over the E2 (REPORT, INSERT, CONTROL, POLICY and/or QUERY) using O-RAN WG3.TS.E2AP [3] defined procedures. Each of the E2AP Procedures listed in table 5-1 contains specific E2 Node RAN Function dependent Information Elements (IEs). + +**Table 5-1: Relationship between RAN Function specific E2AP Information elements and E2AP Procedures** + +| RAN Function specific E2AP Information Elements | E2AP Information Element reference | Related E2AP Procedures | +|-------------------------------------------------|-------------------------------------|---------------------------------------------------| +| <i>RIC Event Trigger Definition</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.9 | RIC Subscription<br>RIC Subscription Modification | +| <i>RIC Action Definition</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.12 | RIC Subscription<br>RIC Subscription Modification | +| <i>RIC Indication Header</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.17 | RIC Indication | +| <i>RIC Indication Message</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.16 | RIC Indication | +| <i>RIC Call Process ID</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.18 | RIC Indication<br>RIC Control | +| <i>RIC Control Header</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.20 | RIC Control | +| <i>RIC Control Message</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.19 | RIC Control | +| <i>RIC Control Outcome</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.25 | RIC Control | +| <i>RIC Query Header</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.36 | RIC Query | +| <i>RIC Query Definition</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.37 | RIC Query | +| <i>RIC Query Outcome</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.38 | RIC Query | +| <i>RAN Function Definition</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.23 | E2 Setup<br>RIC Service Update | + +All of these RAN Function specific E2AP IEs are defined in O-RAN WG3.TS.E2AP [3] as "OCTET STRING". + +The purpose of this specification is to define the contents of these fields for the specific RAN function "Lower Layers Control". + +# 6 RAN function service model description + +## 6.1 RAN function overview + +For the purposes of this E2 Service Model, E2SM-LLC, the E2 Node terminating the E2 Interface is assumed to host one or more instances of the RAN Function which performs the following functionalities: + +- E2 REPORT services used to expose UE related lower layers information + +- E2 CONTROL services used to initiate control of UE level lower layers parameters + +This E2SM specification provides a set of RAN Function exposure services described in clause 6.2 and has been prepared with the assumption that the same E2SM may be used to describe either a single RAN Function in the E2 Node handling all RAN control related call processes or more than one RAN Function in the E2 Node with each instance handling a subset of the RAN control related call processes on the E2 Node. + +## 6.2 RAN function exposure services + +### 6.2.1 REPORT service + +The “Lower Layers Control” RAN Function provides selective support of the following **REPORT** services: + +- UE level PHY/MAC information, used for estimating the channels +- Traffic status, used for triggering E2 Control + +### 6.2.2 INSERT service + +Void + +### 6.2.3 CONTROL service + +The “Lower Layers Control” RAN Function provides selective support of the following **CONTROL** services: + +- UE level control of handling the scheduling of specific logical channels +- UE level control of parameters for scheduling transmissions + +### 6.2.4 POLICY service + +Void + +### 6.2.5 QUERY service + +Void + +## 6.3 REPORT service description + +The E2SM-LLC REPORT service requirements defined in Clause 6.2.1 are offered using a set of REPORT Styles. All REPORT styles are implemented using a set of IEs for Action Definition, RIC Indication Header and RIC Indication Message and have specific Event Trigger approach. + +The following REPORT styles are supported: + +- Lower Layers Information (LLI) Copy: This REPORT style is initiated by “Lower Layers Information Event” Event Trigger and is used to report PHY and MAC information received from UEs along with UE associated information when the event trigger conditions are satisfied. +- Lower Layers Measurements: This REPORT style is initiated by “Periodic” Event Trigger and is used to report traffic information per logical channel per UE and to report slot timestamps when the event trigger conditions are satisfied. + +## 6.4 INSERT service description + +Void + +## 6.5 CONTROL service description + +The E2SM-LLC CONTROL service requirements defined in Clause 6.2.3 are offered using a set of CONTROL Styles. Each style corresponds to a set of “CONTROL Action”, where each “CONTROL Action” deals with a specific functionality and has a set of associated RAN parameters, provided in a mapping table. All CONTROL Service styles are implemented using a set of IEs constituting a “RIC Control Request Header” and a “RIC Control Request Message” to deliver RAN Control-related CONTROL services. A “CONTROL Action” containing one or more RAN parameters and their associated values can be sent asynchronously from the RIC to the E2 node. + +The following CONTROL styles are supported: + +- UE level control of handling of scheduling specific logical channels +- UE level control of parameters for scheduling transmissions + +## 6.6 POLICY service description + +Void + +## 6.7 QUERY service description + +Void + +# --- 7 RAN function description + +## 7.1 RAN function definition + +The E2AP [3] procedures E2 Setup and RIC Service Update are used to transport the RAN Function Description. + +For the specific RAN Function, the *RAN Function Definition* IE shall report the following information: + +- RAN Function name along with associated information on E2SM definition +- Event trigger styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **REPORT** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **INSERT** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **CONTROL** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **POLICY** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **QUERY** Service styles list along with the corresponding encoding type for each associated E2AP IE. + +## 7.2 RAN function name + +RAN Function Short Name “ORAN-E2SM-LLC” + +RAN Function name description “Lower Layers Control” + +RAN Function Instance, required when and if E2 Node exposes more than one instance of a RAN Function based on this E2SM. + +## 7.3 Event trigger definition styles + +### 7.3.1 RIC Event Trigger Definition IE style list + +| RIC Style Type | Style Name | Supported RIC Service Style | | | Style Description | +|----------------|------------------------------|-----------------------------|--------|--------|------------------------------------------------------------------------------| +| | | Report | Insert | Policy | | +| 1 | Low Layers Information Event | 1 | - | - | Triggering conditions are based on arrival of control message or PHY signal. | +| 2 | Periodic | 2 | - | - | Triggered at specific time periods. | + +### 7.3.2 RIC Event Trigger Definition IE style 1: Lower Layers Information Event + +This *RIC Event Trigger Definition* IE style is used to detect a specific control message or PHY signals received by E2 Node from a UE. The E2 Node can also be configured simultaneously to detect multiple messages and to trigger on any logical combination of the configured message events. + +Each message event configured can be further conditioned to be associated only for a certain UE or group of UEs as indicated by the *Associated UE Info* IE if included. In case that the *Global Associated UE Info* IE is included, the information is applied uniformly to all the message events configured and the IE shall override any *Associated UE Info* IE included for some message events. + +For each message event configured, Event Trigger Condition ID is assigned so that E2 Node can reply to Near-RT RIC in the RIC INDICATION message to inform which event(s) are the cause for triggering. + +This *RIC Event Trigger Definition* IE style uses *E2SM-LLC Event Trigger Definition Format 1* IE (8.2.1.1.1). + +### 7.3.3 RIC Event trigger definition IE style 2: Periodic + +This *RIC Event Trigger Definition* IE style is used to trigger an E2 Node to send periodic reports to the Near RT-RIC at a specified time period. + +The event configured can be further conditioned to be associated only for a certain UE or group of UEs as indicated by the *Associated UE Info* IE if included. + +This *RIC Event Trigger Definition* IE style uses *RIC Event Trigger Definition Format 2* IE (8.2.1.1.2). + +## 7.4 Supported RIC REPORT services + +### 7.4.1 REPORT service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|------------|-------------------------------------------------------------------------------------| +| 1 | LLI copy | This style is used to report a copy of LLI received from UE. | +| 2 | Periodic | This style is used to report the lower layers measurements collected by the E2 Node | + +### 7.4.2 REPORT service style 1: Lower layers information copy + +#### 7.4.2.1 REPORT service style description + +This **REPORT** Service style provides the copy of PHY and Control information received from UEs to be carried as a transparent container in the *RIC Indication Message* IE. + +This **REPORT** Service style is initiated by Event Trigger style 1: Lower Layers Information Event. + +#### 7.4.2.2 REPORT service *RIC Action Definition* IE contents + +The Action Definition for this service style is used to request E2 Node to report a copy of received UE specific LLI. The action definition indicates which related UE specific LLI is to be reported along with the Control message or PHY signal that triggers this report service. + +This **REPORT** Service style uses the *E2SM-LLC Action Definition Format 1* IE (8.2.1.2.1). + +#### 7.4.2.3 REPORT service *RIC Indication Header* IE contents + +This **REPORT** Service style uses the *E2SM-LLC Indication Header Format 1* IE (8.2.1.3.1) + +#### 7.4.2.4 REPORT service *RIC Indication Message* IE contents + +The **REPORT** Service *RIC Indication Message* IE carries the content of the received LLI indicated in the *RIC Action Definition* IE. + +This **REPORT** Service style uses the *E2SM-LLC Indication Message Format 1* IE (8.2.1.4.1). + +### 7.4.3 REPORT Service Style 2: Lower layers measurements + +#### 7.4.3.1 REPORT Service Style description + +This **REPORT** Service style provides UE related lower layers information. The information is carried in the *RIC Indication Message* IE along with an associated *RIC Indication Header* IE providing information related event trigger conditions. The required information to be provided is controlled using the associated *RIC Action Definition* IE parameters. + +This **REPORT** Service style enables the E2 Node to report: + +- L1 per UE measurements including + - HARQ ACK/NACK/DTX counts +- L2 per UE information including + - PDCP and RLC buffer statuses +- Time synchronization + +This **REPORT** Service style is initiated by Event Trigger style 2: Periodic. + +#### 7.4.3.2 REPORT Service *RIC Action Definition* IE contents + +The Action Definition for this service style indicates the set of lower layers information parameters to be reported on a periodic basis. + +This **REPORT** Service style uses the *E2SM-LLC Action Definition IE Format 2* (8.2.1.2.2). + +#### 7.4.3.3 REPORT Service *RIC Indication Header* IE contents + +This **REPORT** Service style uses the *E2SM-LLC Indication Header IE Format 1* (8.2.1.3.1). + +#### 7.4.3.4 REPORT Service *RIC Indication Message* IE contents + +The **REPORT** Service *RIC Indication Message* IE carries the requested lower layers measurements indicated in the *RIC Action Definition* IE. + +This **REPORT** Service style uses the *E2SM-LLC Indication Message IE Format 2* (8.2.1.4.2). + +## 7.5 Supported RIC INSERT services + +Void + +## 7.6 Supported RIC CONTROL services + +### 7.6.1 CONTROL service style types + +| RIC Style Type | Style Name | Style Description | +|----------------|-----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Logical Channels Handling control | Used for taking control of scheduling specific logical channels. Belongs to Fundamental level CONTROL Services. | +| 2 | Scheduling parameters control | Used to provide scheduling related parameters to O-DU for specific data and control flows per slot. Belongs to Fundamental level CONTROL Services. | + +Each of the Control Service styles listed above points to adopt the following common features: + +- Control Action ID: The index ID for the individual control action under a given Control Service style. +- Control Action Name: Indicates the functionality of the E2 node which is controlled by Near-RT RIC +- Control Action Description: Describes the control action and functionality of the receiving E2 Node. + +The details of the individual Control Service styles are provided in subsequent sections. + +### 7.6.2 CONTROL service style 1: Logical channels handling control + +#### 7.6.2.1 CONTROL service style description + +This **CONTROL** Service style provides a mechanism to directly control and monitor the handling of logical channels. + +Applications of this service include: + +- Handover of RLC bearers' scheduling to Near-RT RIC + +The supported RAN control actions and the corresponding RAN parameters are as follows. + +| Control Action ID | Control Action Name | Control Action description | Is UE group-based control action allowed | Associated IE | +|-------------------|--------------------------------------|--------------------------------------------------------------------|------------------------------------------|---------------| +| 1 | DL Logical Channels Handling control | To control the handling of scheduling specific DL logical channels | NO | 8.3.25 | + +#### 7.6.2.2 CONTROL service *RIC Control Header* IE contents + +This **CONTROL** service *RIC Control Header* IE contains the *RIC Style Type* IE and *Control Action ID* IE. + +This **CONTROL** style uses *E2SM-LLC Control Header Format 1* IE (8.2.1.6.1). + +#### 7.6.2.3 CONTROL service *RIC Control Message* IE contents + +This **CONTROL** Service *RIC Control Message* IE contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style, controlled by the near-RT RIC along with the values for these parameters, as set by the RIC. + +This **CONTROL** style uses *E2SM-LLC Control Message* IE Format 1 (8.2.1.7.1). + +#### 7.6.2.4 CONTROL service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE is not supported for this CONTROL service style. + +#### 7.6.2.5 CONTROL service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a list of RAN Parameters and is used to carry information concerning the outcome of executing the RIC Control Request. + +This **CONTROL** style uses *E2SM-LLC Control Outcome* IE Format 1 (8.2.1.8.1). + +### 7.6.3 CONTROL Service Style 2: Scheduling Parameters Control + +#### 7.6.3.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to directly control and monitor the application of scheduling and precoding parameters + +Applications of this service include: + +- Served Radio Bearers scheduling parameters control + +The supported RAN control actions and the corresponding RAN parameters are as follows. + +| Control Action ID | Control Action Name | Control Action description | Is UE group-based control action allowed | Associated IE | +|-------------------|----------------------------------|-----------------------------------------------|------------------------------------------|---------------| +| 1 | DL scheduling parameters control | To control the scheduling parameters per slot | NO | 8.3.26 | + +#### 7.6.3.2 CONTROL Service *RIC Control Header* IE contents + +This **CONTROL** Service *RIC Control Header* IE contains the *RIC Style Type* IE and *Control Action ID* IE. + +This **CONTROL** style uses *E2SM-LLC Control Header Format 1* IE (8.2.1.6.1). + +#### 7.6.3.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** Service *RIC Control Message* IE contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style, controlled by the Near-RT RIC along with the values for these parameters, as set by the RIC. + +This **CONTROL** style uses *E2SM-LLC Control Message* IE Format 1 (8.2.1.7.1). + +#### 7.6.3.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE is not supported for this CONTROL service style. + +#### 7.6.3.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a list of parameters and is used to carry information concerning the outcome of executing the RIC Control Request. + +This **CONTROL** style uses *E2SM-LLC Control Outcome* IE Format 1 (8.2.1.8.1). + +## 7.7 Supported RIC POLICY services + +Void + +## 7.8 Supported RIC QUERY services + +Void + +## 7.9 Supported RIC service styles and E2SM IE formats + +Table 7.9-1, Table 7.9-2 and Table 7.9-3 provide a summary of the E2SM IE Formats defined to support this E2SM specification. + +**Table 7.9-1: Summary of the E2SM IE Formats defined to support RIC Event Trigger Styles** + +| RIC Event Trigger Style | Event Trigger Definition Format | +|-------------------------|---------------------------------| +| Style 1 | 1 | +| Style 2 | 2 | + +**Table 7.9-2: Summary of the E2SM IE Formats defined to support RIC Service Styles** + +| RIC Service Style | Action Definition Format | Indication Header Format | Indication Message Format | Call Process ID Format | Control Header Format | Control Message Format | Control Outcome Format | +|-------------------|--------------------------|--------------------------|---------------------------|------------------------|-----------------------|------------------------|------------------------| +| <b>REPORT</b> | | | | | | | | +| Style 1 | 1 | 1 | 1 | | | | | +| Style 2 | 2 | 1 | 2 | | | | | +| | | | | | | | | +| <b>INSERT</b> | | | | | | | | +| | | | | | | | | +| <b>CONTROL</b> | | | | | | | | +| Style 1 | | | | | 1 | 1 | 1 | +| Style 2 | | | | | 1 | 1 | 1 | +| | | | | | | | | +| <b>POLICY</b> | | | | | | | | +| | | | | | | | | + +**Table 7.9-3: Summary of the E2SM IE Formats defined to support RIC Service Styles** + +| RIC Service Style | Query Header Format | Query Definition Format | Query Outcome Format | +|-------------------|---------------------|-------------------------|----------------------| +| <b>QUERY</b> | | | | +| | | | | + +# 8 Elements for E2SM service model + +## 8.1 General + +## 8.2 Message functional definition and content + +### 8.2.1 Messages for RIC Functional procedures + +#### 8.2.1.1 RIC Event Trigger Definition IE + +This information element is part of the RIC SUBSCRIPTION REQUEST message sent by the Near-RT RIC to an E2 Node and is required for event triggers used to initiate REPORT actions. + +Direction: NEAR-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|-------|-----------------------|--------------------------------| +| <b>CHOICE</b> Event Trigger Format | | | | | +| >E2SM-LLC Event Trigger Definition Format 1 | M | | 8.2.1.1.1 | Used for Event Trigger Style 1 | +| >E2SM-LLC Event Trigger Definition Format 2 | M | | 8.2.1.1.2 | Used for Event Trigger Style 2 | + +##### 8.2.1.1.1 E2SM-LLC Event Trigger Definition Format 1: Lower Layers Information Event + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|-------------------------|-----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of LLI for Event Trigger | | 1.. <i>maxnoof LLIs</i> | | | +| >Event Trigger Condition ID | M | | 8.3.9 | | +| >Lower Layers Information Type | M | | 8.3.15 | | +| >Associated UE Info | O | | 8.3.12 | Indicates applicable UE(s) for event triggering associated to each message event ("Any" UE if not included). | +| >Logical OR | O | | 8.3.11 | | +| Global Associated UE Info | O | | 8.3.12 | Indicates applicable UE(s) for event triggering, applied to all the message events uniformly. This IE shall override any <i>Associated UE Info</i> IE included for some message events. | + +| Range bound | Explanation | +|-------------|------------------------------------------------------------------------------------------------------| +| maxnoofLLIs | Maximum number of LLIs in a given E2 node for which event trigger can be defined. The value is <63>. | + +##### 8.2.1.1.2 E2SM-LLC Event Trigger Definition Format 2: Periodic + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------|----------|-------|-----------------------|-----------------------------------------------------------------------------| +| Reporting Period | M | | INTEGER (1..65535) | Used to indicate the event triggering period in unit of 1 millisecond | +| Associated UE Info | O | | 8.3.12 | Indicates applicable UE(s) for event triggering ("Any" UE if not included). | + +#### 8.2.1.2 RIC Action Definition IE + +This information element is part of the RIC SUBSCRIPTION REQUEST message sent by the Near-RT RIC to an E2 Node. In this service model, this information element provides additional information for the nominated RIC Action. + +Direction: NEAR-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|----------|-------|-----------------------|--------------------------------| +| RIC Style Type | M | | 8.3.3 | | +| <b>CHOICE</b> Action Definition Format | M | | | | +| >E2SM-LLC Action Definition Format 1 | | | 8.2.1.2.1 | Used by REPORT Service Style 1 | +| >E2SM-LLC Action Definition Format 2 | | | 8.2.1.2.2 | Used by REPORT Service Style 2 | + +##### 8.2.1.2.1 E2SM-LLC Action Definition Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------|----------|-------|-----------------------|-----------------------| +| Lower Layers Information Type | M | | 8.3.15 | | + +##### 8.2.1.2.2 E2SM-LLC Action Definition Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|----------------------------------|-----------------------|-----------------------| +| List of Measurement to Report | | 1..<maxnoofMeasurementsToReport> | | | +| >Lower Layers Measurement Type | M | | 8.3.16 | | + +| Range bound | Explanation | +|-----------------------------|---------------------------------------------------------------------------------------------------------| +| maxnoofMeasurementsToReport | Maximum no. of lower layers measurements supported by Action Definition Format 2. The value is <65535>. | + +#### 8.2.1.3 RIC Indication Header IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to the Near-RT RIC and is required for REPORT action. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Indication Header Format</i> | | | | | +| >E2SM-LLC Indication Header Format 1 | M | | 8.2.1.3.1 | | + +##### 8.2.1.3.1 E2SM-LLC Indication Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------|-----------------------|----------------------------| +| Event Trigger Condition ID | O | | 8.3.9 | Event Trigger Condition ID | + +#### 8.2.1.4 RIC Indication Message IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to the Near-RT RIC and is required for REPORT action. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Indication Message Format</i> | M | | | | +| >E2SM-LLC Indication Message Format 1 | | | 8.2.1.4.1 | | +| >E2SM-LLC Indication Message Format 2 | | | 8.2.1.4.2 | | + +##### 8.2.1.4.1 E2SM-LLC Indication Message Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|-------|-----------------------|---------------------------------------------------------------------------------------| +| Slot Time Stamp | M | | 8.3.18 | Indicates the slot in which the latest received parameter was received by the E2 Node | +| <b>CHOICE</b> Lower Layers Information Type | M | | | | +| >SRS | | | 8.3.19 | | +| >CSI | | | 8.3.20 | | + +##### 8.2.1.4.2 E2SM-LLC Indication Message Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------|----------|----------------------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Lower Layers Measurements | | 1.. <i><maxnoofMeasurements></i> | | | +| >Slot Time Stamp | M | | 8.3.18 | Indicates the last slot of the collected data in the report.<br>When the Measurement Type is 'Slot Time Stamp', indicates the slot at the time the message is sent. | +| >CHOICE Lower Layers Measurement Type | M | | | | +| >>DL RLC Buffer Status | | | 8.3.21 | | +| >>DL PDCP Buffer Status | | | 8.3.22 | | +| >>DL HARQ Statistics | | | 8.3.23 | | +| >>Slot Time Stamp | | | NULL | | + +| Range bound | Explanation | +|---------------------|---------------------------------------------------------------------------------------------| +| maxnoofMeasurements | Maximum number of measurements supported by Indication Message Format 2. The value is <63>. | + +#### 8.2.1.5 RIC CALL PROCESS ID IE + +Void + +#### 8.2.1.6 RIC CONTROL HEADER IE + +This information element is part of the RIC CONTROL message sent by the Near-RT RIC to an E2 Node and is required for RIC Control Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> Control Header Format | M | | | | +| >E2SM-LLC Control Header Format 1 | | | 8.2.1.6.1 | | + +##### 8.2.1.6.1 E2SM-LLC Control Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------|----------|-------|-----------------------|-----------------------| +| RIC Style Type | M | | 8.3.3 | | +| Control Action ID | M | | 8.3.6 | Refer to clause 7.6 | + +#### 8.2.1.7 RIC CONTROL MESSAGE IE + +This information element is part of the RIC CONTROL message sent by the Near-RT RIC to an E2 Node and is required for RIC Control Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Control Message Format</i> | M | | | | +| >E2SM-LLC Control Message Format 1 | | | 8.2.1.7.1 | | + +##### 8.2.1.7.1 E2SM-LLC Control Message Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|-------|-----------------------|--------------------------------------------------------| +| CHOICE Control Type | M | | | | +| >Logical Channel Handling Control | | | 8.3.25 | Only applicable to Control Service Style 1 Action ID 1 | +| >DL Scheduling Control | | | 8.3.26 | Only applicable to Control Service Style 2 Action ID 1 | + +#### 8.2.1.8 RIC CONTROL OUTCOME IE + +This information element is part of the RIC CONTROL ACKNOWLEDGEMENT and RIC CONTROL FAILURE messages and is sent by the E2 Node to the Near-RT RIC and is required for RIC Control Procedure. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Control Outcome Format</i> | M | | | | +| >E2SM-LLC Control Outcome Format 1 | | | 8.2.1.8.1 | | + +##### 8.2.1.8.1 E2SM-LLC Control Outcome Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------|----------|-------|-----------------------|---------------------------------------------------------| +| CHOICE Control Parameter Type | M | | | | +| >Logical Channel Handling | | | 8.3.24 | Only applicable for Control Service Style 1 Action ID 1 | +| >DL Scheduling Parameters | | | 8.3.27 | Only applicable for Control Service Style 2 Action ID 1 | + +### 8.2.2 Messages for RIC global procedures + +#### 8.2.2.1 RAN Function Definition IE + +This information element is part of the E2 SETUP REQUEST, and RIC SERVICE UPDATE message sent by the E2 Node to the Near-RT RIC and is used to provide all required information for the Near-RT RIC to determine how a given E2 Node has been configured to support a given RAN Function specific E2SM. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------|----------|-------|-----------------------|-----------------------| +| RAN Function Name | M | | 8.3.2 | | +| RAN Function Definition for EVENT TRIGGER | O | | 8.2.2.2 | | +| RAN Function Definition for REPORT | O | | 8.2.2.3 | | +| RAN Function Definition for CONTROL | O | | 8.2.2.4 | | + +#### 8.2.2.2 RAN Function Definition for EVENT TRIGGER + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|---------------------------|-----------------------|-----------------------| +| List of EVENT TRIGGER styles | | 1..<br><maxnoofRICStyles> | | | +| >RIC Event Trigger Style Type | M | | 8.3.3 | | +| >RIC Event Trigger Style Name | M | | 8.3.4 | | +| >RIC Event Trigger Format Type | M | | 8.3.5 | | + +| Range bound | Explanation | +|------------------|---------------------------------------------------------------------| +| maxnoofRICStyles | Maximum no. of styles supported by RAN Function. The value is <63>. | + +#### 8.2.2.3 RAN Function Definition for REPORT + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------|----------|---------------------------|-----------------------|----------------------------------------------| +| List of REPORT styles | | 1..<br><maxnoofRICStyles> | | | +| >RIC Report Style Type | M | | 8.3.3 | | +| >RIC Report Style Name | M | | 8.3.4 | | +| >Supported RIC Event Trigger Style Type | M | | 8.3.3 | | +| >RIC Report Action Format Type | M | | 8.3.5 | Action Definition type used by Report style | +| >RIC Indication Header Format Type | M | | 8.3.5 | Indication Header type used by Report style | +| >RIC Indication Message Format Type | M | | 8.3.5 | Indication Message type used by Report style | + +| Range bound | Explanation | +|------------------|---------------------------------------------------------------------| +| maxnoofRICStyles | Maximum no. of styles supported by RAN Function. The value is <63>. | + +#### 8.2.2.4 RAN Function Definition for CONTROL + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|-----------------------| +|---------------|----------|-------|-----------------------|-----------------------| + +| | | | | | +|----------------------------------|---|-------------------------------|-------|--| +| List of CONTROL styles | | 1..<br><maxnoofRICStyles> | | | +| >RIC Control Style Type | M | | 8.3.3 | | +| >RIC Control Style Name | M | | 8.3.4 | | +| >List of Control Actions | | 0..<br><maxnoofControlAction> | | | +| >>Control Action ID | M | | 8.3.6 | | +| >>Control Action Name | M | | 8.3.7 | | +| >RIC Control Header Format Type | M | | 8.3.5 | | +| >RIC Control Message Format Type | M | | 8.3.5 | | +| >RIC Call Process ID Format Type | O | | 8.3.5 | | +| >RIC Control Outcome Format Type | M | | 8.3.5 | | + +| Range bound | Explanation | +|----------------------|---------------------------------------------------------------------------------| +| maxnoofRICStyles | Maximum no. of styles supported by RAN Function. The value is <63>. | +| maxnoofControlAction | Maximum no. of Control actions supported by RAN Function. The value is <65535>. | + +## 8.3 Information Element definitions + +### 8.3.1 General + +When specifying information elements which are to be represented by bit strings, if not otherwise specifically stated in the semantics description of the concerned IE or elsewhere, the following principle applies with regards to the ordering of bits: + +- The first bit (leftmost bit) contains the most significant bit (MSB); +- The last bit (rightmost bit) contains the least significant bit (LSB); +- When importing bit strings from other specifications, the first bit of the bit string contains the first bit of the concerned information. + +### 8.3.2 RAN Function Name + +This IE is defined in O-RAN WG3.TS.E2SM [4] clause 6.2.2.1. + +### 8.3.3 RIC Style Type + +This IE is defined in O-RAN WG3.TS.E2SM [4] clause 6.2.2.2. + +### 8.3.4 RIC Style Name + +This IE is defined in O-RAN WG3.TS.E2SM [4] clause 6.2.2.3. + +### 8.3.5 RIC Format Type + +This IE is defined in O-RAN WG3.TS.E2SM [4] clause 6.2.2.4. + +### 8.3.6 Control Action ID + +This IE uniquely identifies an action of a given RIC Control style. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------|----------|-------|--------------------------|-----------------------| +| Control Action ID | M | | INTEGER (1.. 65535, ...) | | + +### 8.3.7 Control Action Name + +This IE defines the name of a given control action. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-------------------------------------|-----------------------| +| Control Action Name | M | | PrintableString(SIZE(1.. 150, ...)) | | + +### 8.3.8 UE ID + +This IE is defined in O-RAN WG3.TS.E2SM [4] clause 6.2.2.6. + +### 8.3.9 Event Trigger Condition ID + +This IE defines an identifier for event trigger conditions configured for a specific Event Trigger style. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------|-------------------------|-----------------------| +| Event Trigger Condition ID | M | | INTEGER (1..65535, ...) | | + +### 8.3.10 Event Trigger ID for UE + +This IE defines an identifier for a specific UE related condition configured for event triggering. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|-------------------------|-----------------------| +| Event Trigger ID for UE | M | | INTEGER (1..65535, ...) | | + +### 8.3.11 Logical OR + +This IE indicates a logical ("and" or "or") connection of the current condition to the next condition in a given sequence of conditions. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-------------------------------|---------------------------------------------------------------------------------------| +| Logical OR | M | | ENUMERATED (true, false, ...) | If set to "true", logical connection to the next condition is "or". Otherwise, "and". | + +### 8.3.12 Event Trigger UE Information + +This IE defines a set of applicable UEs for event triggering. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|--------------------|-----------------------|-----------------------| +| List of Associated UE Information | | 1..<maxnoofUEInfo> | | | +| >Event Trigger ID for UE | M | | 8.3.10 | | +| >CHOICE UE Type | | | | | +| >>Individual UE | | | | | + +| | | | | | +|-----------------|---|--|--------|--| +| >>>UE ID | M | | 8.3.8 | | +| >>UE Group | | | | | +| >>>Group of UEs | M | | 8.3.13 | | +| >Logical OR | O | | 8.3.11 | | + +| Range bound | Explanation | +|---------------|------------------------------------------------------------------------------------------------------------------| +| maxnoofUEInfo | Maximum number of UE information in a given E2 node for which event trigger can be defined. The value is <65535> | + +### 8.3.13 Group of UEs + +This IE uniquely identifies a group of UEs. At least one parameter must be included. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|------------------|-----------------------|-----------------------| +| Cell Global ID | O | | 8.3.14 | | +| List of UE Identifiers | | 0..<maxnoof UEs> | | | +| > UE ID | M | | 8.3.8 | | + +| Range bound | Explanation | +|-------------|-------------------------------------------------------------------------------------------------------| +| maxnoofUEs | Maximum number of UEs in a given E2 node for which event trigger can be defined. The value is <65535> | + +### 8.3.14 Cell Global ID + +This IE is defined in O-RAN WG3.TS.E2SM [4] clause 6.2.2.5. + +### 8.3.15 Lower Layers Information Type + +This IE defines the type of lower layers information to trigger on and/or report. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------|----------|-------|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------| +| Lower Layers Information Type | M | | ENUMERATED (SRS, CSI, ...) | SRS refers to received SRS symbols defined in 3GPP TS 38.211 [5] Clause 6.4.1.4.<br>"CSI" Refers to UCI defined in 3GPP TS 38.213 [6] Clause 9. | + +### 8.3.16 Lower Layers Measurement Type + +This IE defines the type of lower layers measurements to trigger on and/or report. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------|----------|-------|----------------------------------------------------------------------------------------------------------------|-----------------------| +| Lower Layers Measurement Type | M | | ENUMERATED<br>(DL_RLC_Buffer_Status,<br>DL_PDCP_Buffer_Status,<br>DL_HARQ_Statistics,<br>Slot_Time_Stamp, ...) | | + +### 8.3.17 Slot Information + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------|----------|-------|-----------------------|-----------------------| +| System Frame Number | M | | INTEGER (0..1023) | | +| <b>CHOICE</b> <i>Slot Index</i> | M | | | | +| >SCS-15 | | | | | +| >>SCS-15 | M | | INTEGER (0..9) | | +| >SCS-30 | | | | | +| >>SCS-30 | M | | INTEGER (0..19) | | +| >SCS-60 | | | | | +| >>SCS-60 M | M | | INTEGER (0..39) | | +| >SCS-120 | | | | | +| >>SCS-120 | M | | INTEGER (0..79) | | + +### 8.3.18 Slot Time Stamp + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Slot Information | M | | 8.3.17 | | +| Slot Start Time | M | | OCTET STRING (SIZE(8)) | Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [7] containing both seconds and fraction parts. Represents the start time of the slot | + +### 8.3.19 SRS + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------|----------|------------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------| +| List of SRS Receive Antennas | | <i>1..<maxnoofReceiveAntennas></i> | | Antennas used to receive the SRS. The antennas shall be listed in the order as defined in O-RAN WG4.TS.CUS [8] Clause 12.5.4. | +| >List of SRS Symbols | | <i><1, 2, 4></i> | | Symbols of the received raw SRS starting with the symbol in position $l_0$ as defined in 3GPP TS 38.211 [5] Clause 6.4.1.4.1. | + +| | | | | | +|--------------------------|-----------------------|--|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| >>SRS Compression Header | C-<br>ifStaticSR<br>S | | OCTET STRING<br>(SIZE(1)) | Compression method and IQ width defined in the M-Plane when the static IQ format and compression method is configured via the M-Plane, formatted as udCompHdr in O-RAN WG4.TS.CUS [8] Clause 8.3.3.13. This parameter shall be included only when SRS related IQ data is transferred from the O-RU with IQ data transfer procedure without C-Plane (see O-RAN WG4.TS.CUS [8] clause 8.3.5.4). | +| >>Raw SRS | M | | OCTET STRING | As defined in O-RAN WG4.TS.CUS [8] Table 8.3.2-1 starting from Octet 13. | + +| Range bound | Explanation | +|------------------------|---------------------------------------------------------------------| +| maxnoofReceiveAntennas | Maximum number of receive antennas supported. The value is <65535>. | + +| Condition | Explanation | +|-------------|--------------------------------------------------------------------------------------------------------------------------------------------| +| ifStaticSRS | This IE shall be present if the configuration of the SRS transfer over the FH is configured as static. Otherwise, it shall not be present. | + +### 8.3.20 CSI + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------|------------------|--------------------------------------|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of CSI UE Identifiers | | 1.. <i><maxnoofUEID></i> | | | +| >UE ID | M | | 8.3.8 | | +| >Channel carrying the UCI | M | | ENUMERATED (PUCCH, PUSCH) | | +| >List of CSI Reports | | 1.. <i><maxnoofCSIReports></i> | | | +| >>CSI Report Config ID | M | | INTEGER (0..47) | CSI- <i>ReportConfigID</i><br>IE in 3GPP TS 38.331 [9] Clause. The ID of this CSI report. | +| >>CSI Fields of CSI Report Part 1 | M | | BIT STRING | 3GPP TS 38.212 [14] Tables 6.3.1.1.2-7/8/8-A/9. CSI fields of CSI part 1 if the CSI report is of two parts, or the CSI report if it is not of two parts. | +| >> CSI Fields of CSI Report Part 2 | C-<br>ifCsiPart2 | | BIT STRING | 3GPP TS 38.212 [14] Tables 6.3.1.1.2-10/11. CSI fields of CSI part 2 if the CSI report is of two parts | + +| Range bound | Explanation | +|-------------------|---------------------------------------------------------------------------------| +| maxnoofUEID | Maximum number of UE Identifiers supported. The value is <i><65535></i> . | +| maxnoofCSIReports | Maximum number of CSI reports per UE supported. The value is <i><255></i> | + +| Condition | Explanation | +|------------|----------------------------------------------------------------------------------------------------------------------| +| ifCsiPart2 | This IE shall be present if the CSI report received from the UE includes part 2. Otherwise, it shall not be present. | + +### 8.3.21 DL RLC Buffer Status + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------|----------|-------------------------------------|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of DL RLC UE Identifiers | | 1.. <i><maxnoofUEID></i> | | | +| >UE ID | M | | 8.3.8 | | +| >List of DL RLC UE Bearers | | 1.. <i><maxnoofUEBearers></i> | | | +| >>LCID | M | | INTEGER (1..32, ...) | <i>logicalChannelId</i> entity IE in 3GPP TS 38.331 [9] Sec 6. Logical Channel ID | +| >>DL RLC Buffer Occupancy | M | | INTEGER | Buffer Occupancy (BO) in number of bytes as defined in 3GPP TS 25.321 [10] clause 8.2.2(c). | +| >>DL RLC HOL Time To Live | M | | INTEGER (0..1023, ...) | Time in units of 0.5ms. The time available for the PDU at the head of the line in the RLC buffer to be transmitted without violating the PDB associated with this LCID. | + +| Range bound | Explanation | +|------------------|--------------------------------------------------------------------------------------| +| maxnoofUEID | Maximum number of UE Identifiers supported. The value is <i><65535></i> . | +| maxnoofUEBearers | Maximum number of reported bearers per UE supported. The value is <i><255></i> | + +### 8.3.22 DL PDCP Buffer Status + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|------------------------------------|------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of DL PDCP UE Identifiers | | <i>1..<maxnoofUEID></i> | | | +| >UE ID | M | | 8.3.8 | | +| >List of DL PDCP UE Bearers | | <i>1..<maxnoofUEBearers></i> | | | +| >>DRB ID | M | | INTEGER (1..32, ...) | DRB ID IE in 3GPP TS 37.483 [11] clause 9.3.1.16 | +| >>DL PDCP Buffer Occupancy | M | | INTEGER | PDCP data volume in number of bytes as defined in 3GPP TS 38.323 [12] clause 5.6. | +| >>DL PDCP HOL Time To Live | M | | INTEGER (0..1023, ...) | Time in units of 0.5ms. The time available for the PDU at the head of the line in the PDCP buffer to be transmitted without violating the PDB associated with this DRB ID. | + +| Range bound | Explanation | +|-------------------------|-------------------------------------------------------------------------| +| <i>maxnoofUEID</i> | Maximum number of UE Identifiers supported. The value is <65535>. | +| <i>maxnoofUEBearers</i> | Maximum number of reported bearers per UE supported. The value is <255> | + +### 8.3.23 DL HARQ Statistics + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|--------------------------|-----------------------|--------------------------------------------------------------------------------| +| List of DL HARQ UE Identifiers | | 1.. <i>maxnoofUEID</i> > | | | +| >HARQ UE ID | M | | 8.3.8 | | +| >List of DL HARQ Codewords | | <1, 2> | | | +| >>DL SU ACK Count | M | | INTEGER | Number of ACKs counted for non-MU-MIMO DL transmissions since the last report | +| >>DL SU NACK Count | M | | INTEGER | Number of NACKs counted for non-MU-MIMO DL transmissions since the last report | +| >>DL SU DTX Count | M | | INTEGER | Number of DTXs counted for non-MU-MIMO DL transmissions since the last report | +| >>DL MU ACK Count | M | | INTEGER | Number of ACKs counted for MU-MIMO DL transmissions since the last report | +| >>DL MU NACK Count | M | | INTEGER | Number of NACKs counted for MU-MIMO DL transmissions since the last report | +| >>DL MU DTX Count | M | | INTEGER | Number of DTXs counted for MU-MIMO DL transmissions since the last report | + +| Range bound | Explanation | +|--------------------|-------------------------------------------------------------------| +| <i>maxnoofUEID</i> | Maximum number of UE Identifiers supported. The value is <65535>. | + +### 8.3.24 Received Timestamp + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------|----------|-------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Received Timestamp | M | | OCTET STRING (SIZE(8)) | <p>Time RIC Control Request message received by RAN Function over E2 interface.</p> <p>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [7] containing both seconds and fraction parts.</p> | + +### 8.3.25 Logical Channel Handling Control + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------------------|----------|------------------------------------------|-----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------| +| List of Logical Channel UE Identifiers | | <i>1..<maxnoofUEID></i> | | | +| >UE ID | M | | 8.3.8 | | +| >List of logical channels controlled by Near-RT RIC to add | | <i>0..<maxnoofLogicalChannels></i> | | The list of bearers for which the O-DU is requested to delegate scheduling decisions to the Near-RT RIC (in addition to the ones already delegated) | +| >>Logical Channel ID | M | | INTEGER (1..32) | <i>LogicalChannelId</i> entity IE in 3GPP TS 38.331 [9] clause 6 | +| >>Starting Slot number | M | | 8.3.17 | The slot number from which the control of scheduling the logical channel starts | +| >List of logical channels to release | | <i>0..<maxnoofLogicalChannels></i> | | The list of bearers the Near-RT RIC will no longer schedule | +| >>Logical Channel ID | M | | INTEGER (1..32) | <i>LogicalChannelId</i> entity IE in 3GPP TS 38.331 [9] clause 6 | + +| | | | | | +|------------------------|---|--|--------|-------------------------------------------------------------------------------------------------------------| +| >>Starting Slot number | M | | 8.3.17 | The slot number from which the control of scheduling the logical channel is being released back to the O-DU | +|------------------------|---|--|--------|-------------------------------------------------------------------------------------------------------------| + +| Range bound | Explanation | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------| +| maxnoofUEID | Maximum number of UE Identifiers supported by E2SM-LLC Indication Message Format 1 IE to be reported. The value is <65535>. | +| maxnoofLogicalChannels | Maximum no. of logical channels. The value is <63>. | + +### 8.3.26 DL Scheduling Control + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------|----------|-------------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of DL Slots to be scheduled | | 1..<maxnoofScheduled DLSlots> | | | +| >Slot Information | M | | 8.3.17 | | +| >List of DL Grants | | 1..<maxnoofDLGrants> | | | +| >>Grant ID | M | | INTEGER (1..63, ...) | This is the ID used by the RIC for the grant it seeks to add to the PDCCH | +| >>BWP ID | O | | INTEGER (0..4, ...) | <i>BWP-Id</i> IE in 3GPP TS 38.331 [9]. Identifies the BWP in which to include the grant. Value of 0 or field not included, indicate the DL Initial BWP | +| >>UE ID | M | | 8.3.8 | | +| >>List of Logical Channels | | 1..<maxnoofLogicalChannels> | | | +| >>>Logical Channel ID | M | | INTEGER (1..32, ...) | <i>LogicalChannelId</i> IE in 3GPP TS 38.331 [9] clause 6 | +| >>>TB1 Number of Bytes | M | | INTEGER | The number of bytes of the logical channel to be included in TB1 of the grant | +| >>>TB2 Number of Bytes | O | | INTEGER | The number of bytes of the logical channel to be included in TB2 of the grant | +| >>CHOICE Downlink Control Information Type | M | | | | +| >>>DCI 1_0 | | | | | + +| | | | | | +|-------------------------|-------------|--|-----------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 4>Use CS-RNTI | O | | | Indicates the use of CS-RNTI in the DCI to activate/deactivate SPS. CS-RNTI not used when not included. | +| 5>SPS Config Index | C-ifSPSList | | INTEGER (0..7, ...) | <i>sps-ConfigIndex</i> IE in 3GPP TS 38.331 [9]. Indicates the index of one of multiple SPS configurations when there are multiple SPS configurations in the <i>SPS-Config</i> IE (3GPP TS 38.331 [9]) of the UE. | +| 5>Activation | M | | ENUMERATED (Activate, Deactivate) | Indicates whether to activate or deactivate the SPS | +| 4>Freq Domain Resources | M | | INTEGER | Representing DL frequency resource allocation type 1 as defined in Clause 5.1.2.2.2 of 3GPP TS 38.214 [13] | +| 4>Time Domain Resources | M | | INTEGER (0..15, ...) | 4 bits of representing resource allocation in time domain as defined in Clause 5.1.2.1 of 3GPP TS 38.214 [13] | +| 4>VRB to PRB Mapping | O | | ENUMERATED (Interleaved, ...) | Not interleaved if not included | +| 4>MCS | M | | INTEGER (0..31, ...) | 5 bits representing the MCS as defined in Clause 5.1.3.1 of 3GPP TS 38.214 [13] | +| 4>Redundancy Version | M | | INTEGER (0..3, ...) | 2 bits as defined in Table 7.3.1.1.1-2 of 3GPP TS 38.212 [14] | +| >>>DCI 1_1 | | | | | +| 4>Use CS-RNTI | O | | | Indicates the use of CS-RNTI in the DCI to activate SPS. CS-RNTI not used when not included. | + +| | | | | | +|-------------------------------|-----------------|--|-------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 5>SPS Config Index | C-<br>ifSPSList | | INTEGER (0..7, ...) | <i>sps-ConfigIndex</i> IE in 3GPP TS 38.331 [9]. Indicates the index of one of multiple SPS configurations when there are multiple SPS configurations in the <i>SPS-Config</i> IE (3GPP TS 38.331 [9]) of the UE. | +| 4>Carrier Indicator | O | | INTEGER (1..7, ...) | As defined in Clause 10.1 of 3GPP TS 38.213 [6]. If not included, indicates the UE serving cell. | +| 4>Freq Domain Resources | M | | BIT STRING | Representing DL frequency resource allocation type 0 or 1 as defined in Clause 7.3.1.2.2 of 3GPP TS 38.212 [14] and Clause 5.1.2.2 of TS 38.214 [13] | +| 4>Time Domain Resources | M | | INTEGER (0..15, ...) | 4 bits representing resource allocation in time domain as defined in Clause 5.1.2.1 of 3GPP TS 38.214 [13] | +| 4>VRB to PRB Mapping | O | | ENUMERATED (Interleaved, ...) | Not interleaved if not included | +| 4>PRB Bundling Size Indicator | O | | INTEGER(0..1, ...) | Only applicable when <i>prb-BundlingType</i> (3GPP TS 38.331 [9]) is set to 'dynamicBundling'. Indicates which of the two bundle size sets configured by <i>dynamicBundling</i> IE to use as specified in Clause 5.1.2.3 of 3GPP TS 38.214 [13]. | +| 4>TB1 MCS | M | | INTEGER (0..31, ...) | 5 bits representing the MCS as defined in Clause 5.1.3.1 of 3GPP TS 38.214 [13] | + +| | | | | | +|-----------------------------------------|---|-----------------------|-------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 4>TB1 Redundancy Version | M | | INTEGER (0..3, ...) | 2 bits as defined in Table 7.3.1.1.1-2 of 3GPP TS 38.212 [14] | +| 4>TB2 MCS | O | | INTEGER (0..31, ...) | 5 bits representing the MCS as defined in Clause 5.1.3.1 of 3GPP TS 38.214 [13] | +| 4>TB2 Redundancy Version | O | | INTEGER (0..3, ...) | 2 bits as defined in Table 7.3.1.1.1-2 of 3GPP TS 38.212 [14] | +| 4>Antenna ports | M | | BIT STRING (SIZE(4..6)) | As defined in Clause 7.3.1.2.2 of 3GPP TS 38.212 [14] | +| 4>Transmission Configuration Indication | O | | INTEGER (0..7) | As defined in Clause 7.4.3.1.2.2 of TS 38.212 [14] | +| 4>SRS Request | O | | BIT STRING (SIZE(2..3)) | If included, identifies the SRS resource set(s) to trigger as defined in Clause 7.3.1.2.2 of 3GPP TS 38.212 [14]. No aperiodic SRS triggering if not included (or set to 0). | +| 4>DMRS Sequence Initialization | M | | INTEGER(0..1) | Selects between two ways of initializing the DMRS sequence as defined in clause 7.4.1.1.1 of 3GPP TS 38.211 [5]. | +| >>>Semi Persistence | | | NULL | Indicates SPS resources being allocated without DCI | +| >List of PDSCH SMGs | | 1..<maxnoofPdschSMGs> | | | +| >>Precoder ID | M | | INTEGER (0..63, ...) | An index to the position in the Sequence of PDSCH Precoders | +| >>SMG Priority | O | | INTEGER (0..31, ...) | Indicates priority of avoiding overwrites, where 0 represents highest priority and 31 represents lowest priority. | + +| | | | | | +|-------------------------------------|---|-----------------------------------------------|-----------------------|-----------------------------------------------------------------------------------------------------------------------| +| >>Start RB | M | | INTEGER | Identifies the lowest virtual RB of the SMG | +| >>Number of RBs | M | | INTEGER | Indicates the number of contiguous virtual RBs, starting from the Start RB, that construct the SMG | +| >>Start Symbol | M | | INTEGER | Identifies the lowest symbol of the SMG | +| >>Number of Symbols | M | | INTEGER | Indicates the number of contiguous symbols that construct the SMG | +| >List of CSI-RS Precoding Bands | | <i>0..<maxnoofCsiRsPrecodingBands></i> | | | +| >>Precoder ID | M | | INTEGER (0..63, ...) | An index to the position in the Sequence of Precoders | +| >>UE ID | M | | 8.3.8 | | +| >>NZP CSI-RS Resource ID | M | | INTEGER (0..191, ...) | <i>NZP-CSI-RS-ResourceId</i> IE in 3GPP TS 38.331 [9]. Identifies the NZP CSI-RS resource | +| >>Start RB | M | | INTEGER | Identifies the lowest RB of the CSI-RS precoding band | +| >>Number of RBs | M | | INTEGER | Indicates the number of contiguous RBs, starting from the Start RB, that construct the CSI-RS precoding band | +| >List of Precoders | | <i>1..<maxnoofPrecoders></i> | | | +| >> Compression Information | O | | | | +| >>> Precoder Compression Header | M | | OCTET STRING | As defined in Clause 7.7.1.2 of O-RAN WG4.TS.CUS [8] | +| >>> Precoder Compression Parameters | M | | OCTET STRING | As defined in Clause 7.7.1.3 of O-RAN WG4.TS.CUS [8] | +| >>List of Precoder Coefficients | M | <i>1..<maxnoofPrecoderCoefficients></i> | | The mapping of the coefficients to layers and antenna elements is as defined in Clause 12.5.3 of O-RAN WG4.TS.CUS [8] | + +| | | | | | +|----------------------------|---|--|---------|-----------------------------------------------------------------------------------------| +| >>> Precoder Coefficient I | M | | INTEGER | The precoder coefficient I value. As defined in Clause 7.7.1.4 of O-RAN WG4.TS.CUS [8]. | +| >>> Precoder Coefficient Q | M | | INTEGER | The precoder coefficient Q value. As defined in Clause 7.7.1.5 of O-RAN WG4.TS.CUS [8]. | + +| Condition | Explanation | +|-----------|-------------------------------------------------------------------------------------------------------------------------------| +| ifSPSList | This IE shall be present if there are multiple SPS configurations in the <i>SPS-Config</i> IE (3GPP TS 38.331 [9]) of the UE. | + +| Range bound | Explanation | +|-----------------------------|----------------------------------------------------------------| +| maxnoofScheduledDLSlots | Maximum no. of slots to be scheduled. The value is <63>. | +| maxnoofDLGrants | Maximum no. of grants per slots. The value is <63>. | +| maxnoofLogicalChannels | Maximum no. of logical channels. The value is <63>. | +| maxnoofPdschSMGs | Maximum no. of spatial multiplexing groups. The value is <63>. | +| maxnoofCsiRsPrecodingBands | Maximum no. of CSI-RS precoding bands. The value is <63>. | +| maxnoofPrecoders | Maximum no. of precoders. The value is <255>. | +| maxnoofPrecoderCoefficients | Maximum no. of precoder coefficients. The value is <65535>. | + +### 8.3.27 DL Scheduling Control Outcome + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|--------------------------------------------|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Received Timestamp | M | | 8.3.24 | | +| Processing Time Margin | M | | INTEGER (-32,767..32,767) | Time margin after processing the information for the first slot included in the Control Message. A negative value indicates by how much time the Control Message was too late to arrive at the E2 Node.<br><br>Carries signed 16-bit fraction of a second resolving ~30 microseconds. | +| List of Slots | | 1.. <i><maxnoofScheduledDLSlots></i> | | | +| >Slot Information | M | | 8.3.17 | | + +| | | | | | +|--------------------------------------|---|-----------------------------|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| >List of DL Grants | | 1..<maxnoofDLGrants> | | The full list of grants included in the Control Message | +| >>Grant ID | M | | | ID of the grant included in the Control Message | +| >>CHOICE Execution Level | M | | | | +| >>>Fully Executed | O | | NULL | | +| >>>Not Fully Executed | O | | | | +| 4>List of Scheduled Logical Channels | | 1..<maxnoofLogicalChannels> | | Shall include the list of all logical channels included in the Control Message for the same Grant ID. | +| 5>Logical Channel ID | M | | INTEGER (1..32, ...) | <i>logicalChannelId</i> IE in 3GPP TS 38.331 [9] Sec 6 | +| 5>Number of Bytes Scheduled | M | | INTEGER | Indicates the number of bytes actually scheduled from the logical channel | +| 5>Cause | M | | INTEGER | Identifies the cause of not sending the number of bytes requested in the Control Message.<br>0= Other<br>1= Information arrived too late<br>2= LCID overwritten by other transmissions.<br>3= Reached maximum number of DCIs for the slot.<br>4= UE not available.<br>5= Resources used for retransmission/s<br>6= Insufficient RLC queue depth | +| >List of Additional DL Allocations | | 0..<maxnoofDLGrants> | | Shall include the list of all DL PDSCH allocations not included in the Control Message and used slot resources. | +| >>UE ID | O | | 8.3.8 | Shall be included if granted to a specific UE | + +| | | | | | +|----------------------------------------------|---|----------------------------------------------|--------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| >>Logical Channel ID | O | | INTEGER<br>(1..32, ...) | <i>logicalChannelId</i> entity IE in 3GPP TS 38.331 [9] Sec 6. Shall be included if it exists for the logical channel. | +| >>Number of Bytes Scheduled | M | | INTEGER | Indicates the number of bytes scheduled | +| >>Start Symbol | O | | INTEGER | Should be included when Logical Channel ID doesn't apply to this allocation | +| >>Number of Symbols | O | | INTEGER | Should be included when Logical Channel ID doesn't apply to this allocation | +| >>Start RB | O | | INTEGER | Should be included when Logical Channel ID doesn't apply to this allocation | +| >>Number of RBs | O | | INTEGER | Should be included when Logical Channel ID doesn't apply to this allocation | +| >List of CSI-RS Precoding Bands Not Executed | | <i>0..<MaxnoofCsiRsPrecodingBands></i> | | Shall include the list of all CSI-RS precoding bands included in the Control Message that were not executed | +| >>CSI-RS Precoding Band ID | M | | INTEGER<br>(0..maxnoofCsiRsPrecodingBands) | Identifies the position of the CSI-RS Precoding Band Item in the List of CSI-RS Precoding Bands. The value "0" represents the first CSI-RS Precoding Band Item, "1" the second, etc. | +| >>Cause | M | | INTEGER | 0= Other<br>1= Information arrived too late<br>2= Unrecognized UE ID<br>3= Unrecognized NZP CSI-RS Resource ID<br>4= invalid RB range<br>5= Invalid number of Coef.<br>6= Coef gain is too high | + +## 8.4 Information Element abstract syntax (with ASN.1) + +### 8.4.1 General + +E2SM-LLC ASN.1 definition conforms to ITU-T Recommendation X.680 [15], ITU-T Recommendation X.681 [16]. + +Clause 8.4.2 presents the Abstract Syntax of the E2SM information elements to be carried within the O-RAN WG3.TS.E2AP [3] protocol messages with ASN.1. In case there is contradiction between the ASN.1 definition in this clause and the tabular format in clauses 8.2 and 8.3, the ASN.1 shall take precedence, except for the definition of conditions for the presence of conditional elements, in which the tabular format shall take precedence. + +If an E2SM information element carried as an OCTET STRING in an O-RAN WG3.TS.E2AP [3] message that is not constructed as defined above is received, this shall be considered as Abstract Syntax Error, and the message shall be handled as defined for Abstract Syntax Error in clause 8. + +### 8.4.2 Information Element Definitions + +``` +-- ASN1START +-- ***** +-- E2SM-LLC Information Element Definitions +-- ***** + +E2SM-LLC-IEs { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version1(1) +e2sm(2) e2sm-LLC-IEs (5) } + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +-- ***** +-- E2SM Common IEs +-- ***** + +IMPORTS + RANfunction-Name, + RIC-Style-Name, + RIC-Style-Type, + RIC-Format-Type, + CGI, + UEID +FROM E2SM-COMMON-IEs; + +-- ***** +-- CONSTANTS +-- ***** + +maxnoofLLIs INTEGER ::= 63 +maxnoofMeasurementsToReport INTEGER ::= 65535 +maxnoofMeasurements INTEGER ::= 63 +maxnoofRICStyles INTEGER ::= 63 +maxnoofControlAction INTEGER ::= 65535 +maxnoofUEInfo INTEGER ::= 65535 +maxnoofUEs INTEGER ::= 65535 +maxnoofReceiveAntennas INTEGER ::= 65535 +maxnoofUEID INTEGER ::= 65535 +maxnoofCSIReports INTEGER ::= 255 +maxnoofUEBearers INTEGER ::= 255 +maxnoofLogicalChannels INTEGER ::= 63 +maxnoofScheduledDLSlots INTEGER ::= 63 +maxnoofDLGrants INTEGER ::= 63 +maxnoofPdschSMGs INTEGER ::= 63 +maxnoofCsiRsPrecodingBands INTEGER ::= 63 +maxnoofPrecoders INTEGER ::= 255 +maxnoofPrecoderCoefficients INTEGER ::= 65535 +``` + +``` + +-- +-- IEs +-- + +LogicalOR ::= ENUMERATED {true, false, ...} + +LowerLayers-Info-Type ::= ENUMERATED {srs, csi,...} + +LowerLayers-Meas-Type ::= ENUMERATED { dl-rlc-buffer-status, dl-pdcp-buffer-status, dl-harq-statistics, +slot-time-stamp, ...} + +LogicalChannelID ::= INTEGER (1..32, ...) + +SpsConfigIndex ::= INTEGER (0..7, ...) + +ReceivedTimestamp ::= OCTET STRING (SIZE(8)) + + +-- Event Trigger related IEs + + +EventTrigger-UE-Info ::= SEQUENCE { + ueInfo-List SEQUENCE (SIZE(1..maxnoofUEInfo)) OF EventTrigger-UE-Info-Item, + ... +} + +EventTrigger-UE-Info-Item ::= SEQUENCE { + eventTriggerUEID RIC-EventTrigger-UE-ID, + ueType CHOICE { + ueType-Choice-Individual EventTrigger-UE-Info-Item-Choice-Individual, + ueType-Choice-Group EventTrigger-UE-Info-Item-Choice-Group, + ... + }, + logicalOR LogicalOR OPTIONAL, + ... +} + +EventTrigger-UE-Info-Item-Choice-Individual ::= SEQUENCE { + ueID UEID, + ... +} + +EventTrigger-UE-Info-Item-Choice-Group ::= SEQUENCE { + groupOfUEs GroupOfUEs, + ... +} + +GroupOfUEs ::= SEQUENCE { + cellGlobalID CGI OPTIONAL, + ueIdentifier-List SEQUENCE (SIZE(0..maxnoofUEs)) OF UeIdentifier-Item, + ... +} + +UeIdentifier-Item ::= SEQUENCE { + ueID UEID, + ... +} + + +-- RIC Service related IEs + + +RIC-ControlAction-ID ::= INTEGER (1..65535, ...) + +RIC-ControlAction-Name ::= PrintableString (SIZE(1..150, ...)) + +RIC-EventTriggerCondition-ID ::= INTEGER (1..65535, ...) + +RIC-EventTrigger-UE-ID ::= INTEGER (1..65535, ...) + +SlotTimeStamp ::= SEQUENCE { + slotInfo SlotInfo, + +``` + +``` + + slotStartTime OCTET STRING (SIZE(8)), + ... + } + +SlotInfo ::= SEQUENCE { + systemFramNumber INTEGER (0..1023, ...), + slotIndex CHOICE { + scs-15 INTEGER (0..9), + scs-30 INTEGER (0..19), + scs-60 INTEGER (0..39), + scs-120 INTEGER (0..79), + ... + }, + ... +} + +SRS ::= SEQUENCE { + srsReceiveAntenna-List SEQUENCE (SIZE(1..maxnoofReceiveAntennas)) OF SrsReceiveAntenna- +Item, + ... +} + +SrsReceiveAntenna-Item ::= SEQUENCE { + srsSymbol-List SEQUENCE (SIZE(1|2|4,...)) OF SrsSymbol-Item, + ... +} + +SrsSymbol-Item ::= SEQUENCE { + srsCompressionHeader OCTET STRING (SIZE(1)), + rawSRS OCTET STRING, + ... +} + +CSI ::= SEQUENCE { + csiUeIdentifier-List SEQUENCE (SIZE(1.. maxnoofUEID)) OF CsiUeIdentifier-Item, + ... +} + +CsiUeIdentifier-Item ::= SEQUENCE { + ueID UEID, + channelCarryingUCI ENUMERATED {pucch, pusch, ...}, + csiReport-List SEQUENCE (SIZE(1.. maxnoofCSIReports)) OF CsiReport-Item, + ... +} + +CsiReport-Item ::= SEQUENCE { + csiReportConfigID INTEGER, + csiFieldsCsiReport-Part1 BIT STRING, + csiFieldsCsiReport-Part2 BIT STRING OPTIONAL, + ... +} + +DlRlcBufferStatus ::= SEQUENCE { + dlRlcUeIdentifiers-List SEQUENCE (SIZE(1.. maxnoofUEID)) OF DlRlcUeIdentifiers-Item, + ... +} + +DlRlcUeIdentifiers-Item ::= SEQUENCE { + ueID UEID, + dlRlcUeBearers-List SEQUENCE (SIZE(1.. maxnoofUEBearers)) OF DlRlcUeBearers-Item, + ... +} + +DlRlcUeBearers-Item ::= SEQUENCE { + lcID INTEGER (1..32, ...), + dlRlcBufferOccupancy INTEGER, + dlRlcHolTimeToLive INTEGER (0..1032, ...), + ... +} + +DlPdcPBufferStatus ::= SEQUENCE { + dlPdcPueIdentifiers-List SEQUENCE (SIZE(1.. maxnoofUEID)) OF DlPdcPueIdentifiers-Item, + ... +} + +DlPdcPueIdentifiers-Item ::= SEQUENCE { + +``` + +``` + + ueID UEID, + dlPdcPueBearers-List SEQUENCE (SIZE(1.. maxnoofUEBearers)) OF DlPdcPueBearers-Item, + ... + } + +DlPdcPueBearers-Item ::= SEQUENCE { + drbID INTEGER (1..32, ...), + dlPdcPBufferOccupancy INTEGER, + dlPdcPHolTimeToLive INTEGER (0..1032, ...), + ... +} + +DlHarqStatistics ::= SEQUENCE { + dlHarqUeIdentifier-List SEQUENCE (SIZE(1.. maxnoofUEID)) OF DlHarqUeIdentifier-Item, + ... +} + +DlHarqUeIdentifier-Item ::= SEQUENCE { + harqUeID UEID, + dlHarqCodeword-List SEQUENCE (SIZE(1|2,...)) OF DlHarqCodeword-Item, + ... +} + +DlHarqCodeword-Item ::= SEQUENCE { + dlSu-ACK-Count INTEGER, + dlSu-NACK-Count INTEGER, + dlSu-DTX-Count INTEGER, + dlMu-ACK-Count INTEGER, + dlMu-NACK-Count INTEGER, + dlMu-DTX-Count INTEGER, + ... +} + +LogicalChannelHandlingControl ::= SEQUENCE { + logicalChannelUEID-List SEQUENCE (SIZE(1.. maxnoofUEID)) OF LogicalChannelUEID-Item, + ... +} + +LogicalChannelUEID-Item ::= SEQUENCE { + ueID UEID, + logicalChanContByNearRTRicToAdd-List SEQUENCE (SIZE(1.. maxnoofLogicalChannels)) OF +LogicalChanContByNearRTRicToAdd-Item, + logicalChanContByNearRTRicToRel-List SEQUENCE (SIZE(1.. maxnoofLogicalChannels)) OF +LogicalChanContByNearRTRicToRel-Item, + ... +} + +LogicalChanContByNearRTRicToAdd-Item ::= SEQUENCE { + logicalChannelID LogicalChannelID, + startingSlotNumber SlotInfo, + ... +} + +LogicalChanContByNearRTRicToRel-Item ::= SEQUENCE { + logicalChannelID LogicalChannelID, + startingSlotNumber SlotInfo, + ... +} + +DlSchedulingControl ::= SEQUENCE { + dlSlotToBeScheduled-List SEQUENCE (SIZE(1.. maxnoofScheduledDLSlots)) OF +DlSlotToBeScheduled-Item, + ... +} + +DlSlotToBeScheduled-Item ::= SEQUENCE { + slotInfo SlotInfo, + dlGrant-List SEQUENCE (SIZE(1.. maxnoofDLGrants)) OF DlGrant-Item, + pdschSMG-List SEQUENCE (SIZE(1.. maxnoofPdschSMGs)) OF PdschSMG-Item, + csiRsPrecodingBand-List SEQUENCE (SIZE(0.. maxnoofCsiRsPrecodingBands)) OF +CsiRsPrecodingBand-Item, + precoder-List SEQUENCE (SIZE(1.. maxnoofPrecoders)) OF Precoder-Item, + ... +} + +DlGrant-Item ::= SEQUENCE { + +``` + +``` + +grantID INTEGER (1..63, ...), +bwpID INTEGER (0..4, ...) OPTIONAL, +ueID UEID, +logicalChannel-List SEQUENCE (SIZE(1.. maxnoofLogicalChannels)) OF LogicalChannel- +Item, + dlControlInfoType CHOICE { + dci-10 Dci-10, + dci-11 Dci-11, + semiPersistence NULL, + ... + }, + ... +} + +LogicalChannel-Item ::= SEQUENCE { + logicalChannelID LogicalChannelID, + noofBytes-TB1 INTEGER, + noofBytes-TB2 INTEGER OPTIONAL, + ... +} + +Dci-10 ::= SEQUENCE { + useCsiRnti SEQUENCE { + spsConfigIndex SpsConfigIndex OPTIONAL, + -- C-ifSPSList: This IE shall be present if there are multiple SPS configurations in the SPS-Config IE + (3GPP TS 38.331) of the UE. It shall not be present otherwise. + activation ENUMERATED {activate, deactivate}, + ... + } + freqDomainResources INTEGER, + timeDomainResources INTEGER (0..15, ...), + vrbToPrbMapping ENUMERATED {interleaved, ...} OPTIONAL, + mcs INTEGER (0..31, ...), + redundancyVersion INTEGER (0..3, ...), + ... +} + +Dci-11 ::= SEQUENCE { + useCsiRnti SEQUENCE { + spsConfigIndex SpsConfigIndex OPTIONAL, + -- C-ifSPSList: This IE shall be present if there are multiple SPS configurations in the SPS-Config IE + (3GPP TS 38.331) of the UE. It shall not be present otherwise. + ... + } + carrierIndicator INTEGER (1..7, ...) OPTIONAL, + freqDomainResources BIT STRING, + timeDomainResources INTEGER (0..15, ...), + vrbToPrbMapping ENUMERATED {interleaved, ...} OPTIONAL, + prbBundlingSizeIndicagor INTEGER (0..1, ...), + mcs-TB1 INTEGER (0..31, ...), + redundancyVersion-TB1 INTEGER (0..3, ...), + mcs-TB2 INTEGER (0..31, ...) OPTIONAL, + redundancyVersion-TB2 INTEGER (0..3, ...) OPTIONAL, + antennaPorts BIT STRING (SIZE(4..6)), + transmissionConfigIndication INTEGER (0..7, ...) OPTIONAL, + srsRequest BIT STRING (SIZE(2..3)) OPTIONAL, + dmrsSequenceInit INTEGER (0..1), + ... +} + +PdschSMG-Item ::= SEQUENCE { + precoderID INTEGER (0..63, ...), + smgProirity INTEGER (0..31, ...) OPTIONAL, + startRB INTEGER, + noofRBs INTEGER, + startSymbol INTEGER, + noofSymbols INTEGER, + ... +} + +CsiRsPrecodingBand-Item ::= SEQUENCE { + precoderID INTEGER (0..63, ...), + ueid UEID, + nzpCsiRsResourceID INTEGER (0..191, ...), + startRB INTEGER, + noofRBs INTEGER, + +``` + +``` + + ... +} + +Precoder-Item ::= SEQUENCE { + compressionInformation SEQUENCE { + precoderCompressionHeader OCTET STRING, + precoderCompressionParam OCTET STRING, + ... + } + precoderCoeff-List OPTIONAL, + SEQUENCE (SIZE(1.. maxnoofPrecoderCoefficients)) OF PrecoderCoeff- +Item, + ... +} + +PrecoderCoeff-Item ::= SEQUENCE { + precoderCoeff-I INTEGER, + precoderCoeff-Q INTEGER, + ... +} + +DlSchedulingControlOutcome ::= SEQUENCE { + receivedTimestamp ReceivedTimestamp, + processingTimeMargin INTEGER (-32767..32767), + scheduledSlotOutcome-List SEQUENCE (SIZE(1.. maxnoofScheduledDLSlots)) OF +DlScheduledSlotOutcome-Item, + ... +} + +DlScheduledSlotOutcome-Item ::= SEQUENCE { + slotInfo SlotInfo, + dlGrantOutcome-List SEQUENCE (SIZE(1.. maxnoofDLGrants)) OF DlGrantOutcome-Item, + additionalDlAllocation-List SEQUENCE (SIZE(0.. maxnoofDLGrants)) OF AdditionalDlAllocation- +Item, + csiRsPrecodingBandsNotExecuted-List SEQUENCE (SIZE(0.. maxnoofCsiRsPrecodingBands)) OF +CsiRsPrecodingBandsNotExecuted-Item, + ... +} + +DlGrantOutcome-Item ::= SEQUENCE { + grantID INTEGER (1..63, ...), + executionLevel CHOICE { + fullyExecuted NULL, + notFullyExecuted SEQUENCE { + scheduledLogicalChannelOutcome-List SEQUENCE (SIZE(1.. maxnoofLogicalChannels)) OF +ScheduledLogicalChannelOutcome-Item, + ... + }, + ... + } +} + +ScheduledLogicalChannelOutcome-Item ::= SEQUENCE { + logicalChannelID LogicalChannelID, + noofBytesScheduled INTEGER, + cause INTEGER, + ... +} + +AdditionalDlAllocation-Item ::= SEQUENCE { + ueid UEID OPTIONAL, + logicalChannelID LogicalChannelID OPTIONAL, + noofBytesScheduled INTEGER, + startSymbol INTEGER OPTIONAL, + noofSymbols INTEGER OPTIONAL, + startRB INTEGER OPTIONAL, + noofRBs INTEGER OPTIONAL, + ... +} + +CsiRsPrecodingBandsNotExecuted-Item ::= SEQUENCE { + csiRsPrecodingBandID INTEGER (0..63, ...), + cause INTEGER, + ... +} + +``` + +``` +-- ***** +-- E2SM-LLC Service Model IEs +-- ***** + +-- ***** +-- Event Trigger OCTET STRING contents +-- ***** + +E2SM-LLC-EventTrigger ::= SEQUENCE { + ric-eventTrigger-formats CHOICE { + eventTrigger-Format1 E2SM-LLC-EventTrigger-Format1, + eventTrigger-Format2 E2SM-LLC-EventTrigger-Format2, + ... + }, + ... +} + +E2SM-LLC-EventTrigger-Format1 ::= SEQUENCE { + message-List SEQUENCE (SIZE(1..maxnoofLLIs)) OF E2SM-LLC-EventTrigger-Format1- + Item, + globalAssociatedUEInfo EventTrigger-UE-Info OPTIONAL, + ... +} + +E2SM-LLC-EventTrigger-Format1-Item ::= SEQUENCE { + ric-eventTriggerCondition-ID RIC-EventTriggerCondition-ID, + lowerLayersInfoType LowerLayers-Info-Type, + associatedUEInfo EventTrigger-UE-Info OPTIONAL, + logicalOR LogicalOR OPTIONAL, + ... +} + +E2SM-LLC-EventTrigger-Format2 ::= SEQUENCE { + reportingPeriod INTEGER (1.. 65535), + associatedUEInfo EventTrigger-UE-Info OPTIONAL, + ... +} + +-- ***** +-- Action Definition OCTET STRING contents +-- ***** + +E2SM-LLC-ActionDefinition ::= SEQUENCE { + ric-Style-Type RIC-Style-Type, + ric-actionDefinition-formats CHOICE { + actionDefinition-Format1 E2SM-LLC-ActionDefinition-Format1, + actionDefinition-Format2 E2SM-LLC-ActionDefinition-Format2, + ... + }, + ... +} + +E2SM-LLC-ActionDefinition-Format1 ::= SEQUENCE { + lowerLayersInfoType LowerLayers-Info-Type, + ... +} + +E2SM-LLC-ActionDefinition-Format2 ::= SEQUENCE { + measurementToReport-List SEQUENCE (SIZE(1.. maxnoofMeasurementsToReport)) OF + MeasurementToReport-Item, + ... +} + +MeasurementToReport-Item ::= SEQUENCE { + lowerLayers-Meas-Type LowerLayers-Meas-Type, + ... +} + +-- ***** +-- Indication Header OCTET STRING contents +-- ***** + +E2SM-LLC-IndicationHeader ::= SEQUENCE { +``` + +``` + + ric-indicationHeader-formats CHOICE { + indicationHeader-Format1 E2SM-LLC-IndicationHeader-Format1, + ... + }, + ... + } + +E2SM-LLC-IndicationHeader-Format1 ::= SEQUENCE { + ric-eventTriggerCondition-ID RIC-EventTriggerCondition-ID OPTIONAL, + ... +} + +-- ***** +-- Indication Message OCTET STRING contents +-- ***** + +E2SM-LLC-IndicationMessage ::= SEQUENCE { + ric-indicationMessage-formats CHOICE { + indicationMessage-Format1 E2SM-LLC-IndicationMessage-Format1, + indicationMessage-Format2 E2SM-LLC-IndicationMessage-Format2, + ... + }, + ... +} + +E2SM-LLC-IndicationMessage-Format1 ::= SEQUENCE { + slotTimeStamp SlotTimeStamp, + lowerLayersInfoType CHOICE { + sRS SRS, + cSI CSI, + ... + }, + ... +} + +E2SM-LLC-IndicationMessage-Format2 ::= SEQUENCE { + lowerLayersMeasurement-List SEQUENCE (SIZE(1.. maxnoofMeasurements)) OF +LowerLayersMeasurement-Item, + ... +} + +LowerLayersMeasurement-Item ::= SEQUENCE { + slotTimeStamp SlotTimeStamp, + lowerLayersMeasurementType CHOICE { + dlRlcBufferStatus DlRlcBufferStatus, + dlPdcPBufferStatus DlPdcPBufferStatus, + dlHarqStatistics DlHarqStatistics, + slotTimeStamp NULL, + ... + }, + ... +} + +-- ***** +-- Control Header OCTET STRING contents +-- ***** + +E2SM-LLC-ControlHeader ::= SEQUENCE { + ric-controlHeader-formats CHOICE { + controlHeader-Format1 E2SM-LLC-ControlHeader-Format1, + ... + }, + ... +} + +E2SM-LLC-ControlHeader-Format1 ::= SEQUENCE { + ric-StyleType RIC-Style-Type, + ric-ControlAction-ID RIC-ControlAction-ID, + ... +} + +-- ***** +-- Control Message OCTET STRING contents + +``` + +``` +-- + +E2SM-LLC-ControlMessage ::= SEQUENCE { + ric-controlMessage-formats CHOICE { + controlMessage-Format1 E2SM-LLC-ControlMessage-Format1, + ... + }, + ... +} + +E2SM-LLC-ControlMessage-Format1 ::= SEQUENCE { + controlType CHOICE { + logicalChannelHandlingControl LogicalChannelHandlingControl, + dlSchedulingControl DlSchedulingControl, + ... + }, + ... +} + +-- +-- Control Outcome OCTET STRING contents +-- + +E2SM-LLC-ControlOutcome ::= SEQUENCE { + ric-controlOutcome-formats CHOICE { + controlOutcome-Format1 E2SM-LLC-ControlOutcome-Format1, + ... + }, + ... +} + +E2SM-LLC-ControlOutcome-Format1 ::= SEQUENCE { + controlType CHOICE { + logicalChannelHandling ReceivedTimestamp, + dlSchedulingParameters DlSchedulingControlOutcome, + ... + }, + ... +} + +-- +-- RAN Function Definition IEs +-- + +E2SM-LLC-RANFunctionDefinition ::= SEQUENCE{ + ranFunction-Name RANfunction-Name, + ranFunctionDefinition-EventTrigger RANFunctionDefinition-EventTrigger OPTIONAL, + ranFunctionDefinition-Report RANFunctionDefinition-Report OPTIONAL, + ranFunctionDefinition-Control RANFunctionDefinition-Control OPTIONAL, + ... +} + +-- Event Trigger +RANFunctionDefinition-EventTrigger ::= SEQUENCE { + ric-EventTriggerStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF RANFunctionDefinition-EventTrigger-Style-Item, + ... +} + +RANFunctionDefinition-EventTrigger-Style-Item ::= SEQUENCE { + ric-EventTriggerStyle-Type RIC-Style-Type, + ric-EventTriggerStyle-Name RIC-Style-Name, + ric-EventTriggerFormat-Type RIC-Format-Type, + ... +} + +-- Report + +RANFunctionDefinition-Report ::= SEQUENCE { +``` + +``` + + ric-ReportStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF RANFunctionDefinition- +Report-Item, + ... +} + +RANFunctionDefinition-Report-Item ::= SEQUENCE { + ric-ReportStyle-Type RIC-Style-Type, + ric-ReportStyle-Name RIC-Style-Name, + ric-SupportedEventTriggerStyle-Type RIC-Style-Type, + ric-ReportActionFormat-Type RIC-Format-Type, + ric-IndicationHeaderFormat-Type RIC-Format-Type, + ric-IndicationMessageFormat-Type RIC-Format-Type, + ... +} + +----- +-- Control +----- + +RANFunctionDefinition-Control ::= SEQUENCE { + ric-ControlStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF RANFunctionDefinition- +Control-Item, + ... +} + +RANFunctionDefinition-Control-Item ::= SEQUENCE { + ric-ControlStyle-Type RIC-Style-Type, + ric-ControlStyle-Name RIC-Style-Name, + ric-ControlAction-List SEQUENCE (SIZE(1..maxnoofControlAction)) OF +RANFunctionDefinition-Control-Action-Item OPTIONAL, + ric-ControlHeaderFormat-Type RIC-Format-Type, + ric-ControlMessageFormat-Type RIC-Format-Type, + ric-CallProcessIDFormat-Type RIC-Format-Type OPTIONAL, + ric-ControlOutcomeFormat-Type RIC-Format-Type, + ... +} + +RANFunctionDefinition-Control-Action-Item ::= SEQUENCE { + ric-ControlAction-ID RIC-ControlAction-ID, + ric-ControlAction-Name RIC-ControlAction-Name, + ... +} + +END + +-- ASN1STOP + +``` + +## 8.5 Message transfer syntax + +E2SM-LLC shall use the ASN.1 Basic Packed Encoding Rules (BASIC-PER) Aligned Variant as transfer syntax, as specified in Recommendation ITU-T X.691 [17]. + +# 9 Handling of unknown, unforeseen and erroneous protocol data + +Clause 10 of TS 36.413 [18] is applicable for the purposes of the present document. + +# Annex (informative): Change history + +| Date | Revision | Description | +|------------|----------|-------------------------------------| +| 2024.06.19 | 00.00.01 | Initial template approval at W3#227 | + +| Date | Revision | Description | +|-------------------|--------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.07.24 | 00.00.02 | Addition of CR <COT-2024.06.28-WG3-CR-0008-E2SM-LLC-Template-Cleanup-v01.docx> approved at WG3#230 | +| 2024.08.14 | 00.00.03 | Addition of CR < COT-2024.07.19-WG3-CR-0009-E2SM-LLC-Clauses-3-4-5-8.2.2-v03.docx> approved at WG3#234 | +| 2024.10.16 | 00.00.04 | Addition of CR < COT-2024.08.22-WG3-CR-0010-E2SM-LLC-Support-REPORT-Service-Style-1-LLI-v03> approved at WG3#239 | +| 2024.11.13 | 00.00.05 | Addition of CRs:<br><COT-2024.10.08-WG3-CR-0012-E2SM-LLC-Support-REPORT-Service-Style-2-Lower-Layers-Measurements-v03><br><COT-2024.10.08-WG3-CR-0013-E2SM-LLC-Support-CONTROL-Service-Style-1-Logical-Channel-Handling-v03><br><COT-2024.10.14-WG3-CR-0014-E2SM-LLC-Support-CONTROL-Service-Style-2-Scheduling-Parameters-v04><br><COT-2024.10.14-WG3-CR-0015-E2SM-LLC-Clauses-6.1-7.1-7.2-7.9-ClauseVoids-v03> approved at Montreal F2F meeting 31/10/2024. | +| 2024.11.26 | 00.00.06 | Addition of CRs:<br>< COT-2024.11.04-WG3-CR-0016-E2SM-LLC-Add-RIC-Call_Process-ID-to-Control-Function-Definition-v02> approved at WG3#244<br>< COT-2024.11.04-WG3-CR-0017-E2SM-LLC-Clauses-8.4-8.5-9-v03> approved at WG3#245 | +| 2024.12.03 | 00.00.07 | Correction of typos | +| <b>2024.12.04</b> | <b>01.00</b> | <b>Initial version</b> | \ No newline at end of file diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/1c4dadbf7cd9fbe1b5fce5b97f1f4923_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/1c4dadbf7cd9fbe1b5fce5b97f1f4923_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..da648f5c70fd2317f2d8cc3367fc2e9c21c17532 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/1c4dadbf7cd9fbe1b5fce5b97f1f4923_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4d0aad6e596e527dbebde4e3d78eaf956d32dc2016cea53fd74a4e6ef67c168e +size 4580 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/38db3420ebc08106dccb6f0ecc6a0d6e_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/38db3420ebc08106dccb6f0ecc6a0d6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de50d0a0cf2bec473e4ab494e0aaeb92d4219783 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/38db3420ebc08106dccb6f0ecc6a0d6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:670aedb94e8c2b1cac15a88c21c471ecd5d7ca775c0d54a923319ffde7def695 +size 4490 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/591890046c73f1ed213267987b143ebb_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/591890046c73f1ed213267987b143ebb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d5dc0d347f191f665d33f5c81ec0b289f361724d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/591890046c73f1ed213267987b143ebb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c05d48830aa7051fbe40cbb33243c9978ffdc2079f8bf40d9ab6117a56af7c8d +size 4542 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/88090d83e337f2a83f461378216f0810_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/88090d83e337f2a83f461378216f0810_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4b9cfc0d1fd907fc43486af7b2bc9cb00702840c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/88090d83e337f2a83f461378216f0810_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4bdab73a68f0fcf67b72c8cf40e90a4611de41b97d8db9048dcc8fe0a828cc50 +size 4482 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/88d0648b30c3d4c271897f352c4de4a5_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/88d0648b30c3d4c271897f352c4de4a5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0bb86b24594fcc59021f4530f31410dccd65ff33 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/88d0648b30c3d4c271897f352c4de4a5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2af85e75727134589950aa91678bd923ba581b044a64379a28725a7484347746 +size 4550 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/9e093378299eb0910f42e72fbe6ad27c_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/9e093378299eb0910f42e72fbe6ad27c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4c305fac3f0526f9da1d2dae8ba1845a5e143dd5 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/9e093378299eb0910f42e72fbe6ad27c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c596d0e67b8c7f0c09107283f3b9d927130d7c26b4db389e225ccb0e78d2c388 +size 4536 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/a9adce18b696d8c554877de0bf88ef02_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/a9adce18b696d8c554877de0bf88ef02_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7073b1bdf7ea42435f9b99642b859384c0dbe106 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/a9adce18b696d8c554877de0bf88ef02_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:195d22f26de9c04673899ce8d1543a5321ca9bc2c8f7d8ae1699a498069c3c4f +size 4528 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/raw.md b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..ac92654f2191f9b2b19d6e7ed10f6cab64082fb3 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00/raw.md @@ -0,0 +1,1604 @@ + + +# --- **O-RAN Work Group 3 (Near-RT RIC and E2 Interface)****E2 Service Model (E2SM)** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +"© 2019. 3GPP™ TSs and TRs are the property of ARIB, ATIS, CCSA, ETSI, TSDSI, TTA and TTC who jointly own the copyright in them. They are subject to further modifications and are therefore provided to you "as is" for information purposes only. Further use is strictly prohibited." + +"© 2020. 3GPP™ TSs and TRs are the property of ARIB, ATIS, CCSA, ETSI, TSDSI, TTA and TTC who jointly own the copyright in them. They are subject to further modifications and are therefore provided to you "as is" for information purposes only. Further use is strictly prohibited." + +"© 2021. 3GPP™ TSs and TRs are the property of ARIB, ATIS, CCSA, ETSI, TSDSI, TTA and TTC who jointly own the copyright in them. They are subject to further modifications and are therefore provided to you "as is" for information purposes only. Further use is strictly prohibited." + +# --- Contents + +| | | +|-------------------------------------------------------------|----| +| List of tables ..... | 4 | +| Foreword..... | 5 | +| Modal verbs terminology..... | 5 | +| 1 Scope ..... | 6 | +| 2 References ..... | 6 | +| 2.1 Normative references ..... | 6 | +| 2.2 Informative references..... | 7 | +| 3 Definition of terms, symbols and abbreviations..... | 7 | +| 3.1 Terms..... | 7 | +| 3.2 Symbols..... | 7 | +| 3.3 Abbreviations ..... | 7 | +| 4 General ..... | 8 | +| 4.1 Procedure specification principles..... | 8 | +| 4.2 Forwards and backwards compatibility ..... | 8 | +| 4.3 Specification notations ..... | 8 | +| 5 E2SM services..... | 8 | +| 6 Common Information Elements for E2SM Service Models ..... | 11 | +| 6.1 General ..... | 11 | +| 6.2 Information Element definitions..... | 11 | +| 6.2.1 General..... | 11 | +| 6.2.2 E2SM common IEs..... | 11 | +| 6.2.3 3GPP derived IEs..... | 18 | +| 6.3 Information Element Abstract Syntax (with ASN.1) ..... | 28 | +| 6.3.1 General..... | 28 | +| 6.3.2 Information Element definitions ..... | 28 | +| 6.3.3 Message transfer syntax..... | 36 | +| Annex (informative): Change History ..... | 37 | + +# --- List of tables + +| | | +|-----------------------------------------------------------------------------------------------------------|----| +| Table 5-1: Relationship between RAN Function specific E2AP Information elements and E2AP procedures ..... | 8 | +| Table 5-2: O-RAN specified E2 Service Models and related OIDs ..... | 10 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG3 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document describes the O-RAN specified RAN Function-specific Service Models supported over E2 (E2SM) and specifies the common elements for use in E2 service models. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +The following referenced documents are necessary for the application of the present document. + +- [1] Void. +- [2] O-RAN WG3.TS.E2GAP, "O-RAN E2 General Aspects and Principles (E2GAP)". +- [3] O-RAN WG3.TS.E2AP, "O-RAN E2 Application Protocol (E2AP)". +- [4] O-RAN WG3.TS.E2SM-NI, "O-RAN E2 Service Model, Network Interface (E2SM-NI)". +- [5] O-RAN WG3.TS.E2SM-KPM, "O-RAN E2 Service Model, KPI Monitor (E2SM-KPM)". +- [6] 3GPP TS 38.413: "NG-RAN; NG Application Protocol (NGAP)". +- [7] 3GPP TS 38.423: "NG-RAN; Xn Application Protocol (XnAP)". +- [8] 3GPP TS 38.473: "NG-RAN; F1 Application Protocol (F1AP)". +- [9] 3GPP TS 37.483: "E1 Application Protocol (E1AP)". +- [10] 3GPP TS 36.413: "E-UTRAN; S1 Application Protocol (S1AP)". +- [11] 3GPP TS 36.423: "E-UTRAN; X2 Application Protocol (X2AP)". +- [12] 3GPP TS 37.473: "W1 interface; Application Protocol (W1AP)". +- [13] Void. +- [14] 3GPP TS 36.331: "E-UTRA; Radio Resource Control (RRC) Protocol Specification". +- [15] 3GPP TS 38.331: "NR; Radio Resource Control (RRC) Protocol Specification". +- [16] Recommendation ITU-T X.680 (07/2002): "Information technology – Abstract Syntax Notation One (ASN.1): Specification of basic notation". +- [17] Recommendation ITU-T X.681 (07/2002): "Information technology – Abstract Syntax Notation One (ASN.1): Information object specification". +- [18] O-RAN WG1.TS.OAD, "O-RAN Architecture Description". +- [19] O-RAN WG3.TS.E2SM-RC, "O-RAN E2 Service Model, RAN Control (E2SM-RC)". + +- [20] O-RAN WG3.TS.E2SM-CCC, "O-RAN E2 Service Model, Cell Configuration and Control (E2SM-CCC)" +- [21] Recommendation ITU-T X.691 (07/2002): "Information technology – ASN.1 encoding rules: Specification of Packed Encoding Rules (PER)". +- [22] O-RAN WG3.TS.E2SM-LLC, "O-RAN E2 Service Model, Lower Layers Control (E2SM-LLC)" + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +Not applicable. + +- [i.1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications" +- [i.2] 3GPP TR 25.921: "Guidelines and principles for protocol description and error handling". + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in 3GPP TR 23.905 [1], O-RAN WG1.TS.OAD [18], O-RAN WG3.TS.E2GAP [2] and the following apply: + +**Format Type:** The identifier used to nominate a specific formatting approach used to encode one of the E2AP IEs defined in this E2SM. + +**RAN Function specific E2AP Information Element:** An E2SM specific implementation of a container used to carry an O-RAN WG3.TS.E2AP [3] defined E2SM specific IE. + +**Style Type:** The identifier used to nominate a specific approach or Style used to expose a given RIC Service (REPORT, INSERT, CONTROL and POLICY). + +## 3.2 Symbols + +Void. + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 23.905 [1], O-RAN WG3.TS.E2GAP [2] and O-RAN WG1.TS.OAD [18] and the following apply: + +Void. + +# 4 General + +## 4.1 Procedure specification principles + +The procedure specification principles defined in O-RAN WG3.TS.E2AP [3] clause 4 shall apply. + +## 4.2 Forwards and backwards compatibility + +The forwards and backwards compatibility of the E2 interface uses the forward and backwards compatibility compatibilities offered by the O-RAN WG3.TS.E2AP [3] protocol. + +## 4.3 Specification notations + +For the purposes of the present document, the following notations apply: + +- IE When referring to an Information Element (IE) in the present document the *Information Element Name* is written with the first letters in each word in upper case characters and all letters in *Italic font* followed by the abbreviation "IE", e.g. *E-RAB ID* IE. +- Value of an IE When referring to the value of an Information Element (IE) in the present document the "Value" is written as it is specified in the present document enclosed by quotation marks, e.g. "Value". + +# 5 E2SM services + +As defined in O-RAN WG3.TS.E2GAP [2], a given RAN Function offers a set of RIC Services to be exposed over the E2 (REPORT, INSERT, CONTROL, POLICY, QUERY and/or ASSISTANCE) using O-RAN WG3.TS.E2AP [3] defined procedures. Each of the E2AP Procedures listed in table 5-1 contains specific E2 Node RAN Function dependent Information Elements (IEs) which shall be defined by a specific E2SM. + +**Table 5-1: Relationship between RAN Function specific E2AP Information elements and E2AP procedures** + +| RAN Function specific E2AP Information Elements | E2AP Information Element reference | Related E2AP Procedures | +|-------------------------------------------------|-------------------------------------|---------------------------------------------------| +| <i>RIC Event Trigger Definition</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.9 | RIC Subscription<br>RIC Subscription Modification | +| <i>RIC Action Definition</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.12 | RIC Subscription<br>RIC Subscription Modification | +| <i>RIC Assistance Header</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.47 | RIC Assistance<br>RIC Assistance Indication | +| <i>RIC Assistance Message</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.48 | RIC Assistance | +| <i>RIC Assistance Outcome</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.51 | RIC Assistance<br>RIC Assistance Indication | +| <i>RIC Indication Header</i> IE | O-RAN WG3.TS.E2AP [3] clause 9.2.17 | RIC Indication | + +| RAN Function specific E2AP Information Elements | E2AP Information Element reference | Related E2AP Procedures | +|-------------------------------------------------|-------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| <i>RIC Indication Message IE</i> | O-RAN WG3.TS.E2AP [3] clause 9.2.16 | RIC Indication | +| <i>RIC Call Process ID IE</i> | O-RAN WG3.TS.E2AP [3] clause 9.2.18 | RIC Indication<br>RIC Control | +| <i>RIC Control Header IE</i> | O-RAN WG3.TS.E2AP [3] clause 9.2.20 | RIC Control | +| <i>RIC Control Message IE</i> | O-RAN WG3.TS.E2AP [3] clause 9.2.19 | RIC Control | +| <i>RIC Control Outcome IE</i> | O-RAN WG3.TS.E2AP [3] clause 9.2.25 | RIC Control | +| <i>RIC Query Header IE</i> | O-RAN WG3.TS.E2AP [3] clause 9.2.36 | RIC Query | +| <i>RIC Query Definition IE</i> | O-RAN WG3.TS.E2AP [3] clause 9.2.37 | RIC Query | +| <i>RIC Query Outcome IE</i> | O-RAN WG3.TS.E2AP [3] clause 9.2.38 | RIC Query | +| <i>RAN Function Definition IE</i> | O-RAN WG3.TS.E2AP [3] clause 9.2.23 | E2 Setup<br>RIC Service Update | +| <i>Service Layer Cause IE</i> | O-RAN WG3.TS.E2AP [3] clause 9.2.53 | RIC Subscription<br>RIC Subscription modification<br>RIC Indication<br>RIC Control<br>RIC Query<br>Error Indication<br>E2 Setup<br>RIC Service Update | + +All of these RAN Function specific E2AP IEs are defined in O-RAN WG3.TS.E2AP [3] as “OCTET STRING”. + +The purpose of the E2SM series of specifications is to define the approach that a given RAN Function specific E2 Service Model shall use to define the contents of these fields. + +The supported O-RAN specified E2 Service Models are presented in table 5-2. + +**Table 5-2: O-RAN specified E2 Service Models and related OIDs** + +| E2SM short name | OID | Syntax language | Scope | +|---------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| E2SM-NI<br>O-RAN<br>WG3.TS.E2SM-NI [4] | iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version1 (1) e2sm(2) e2sm-NI-IEs (1) | ASN.1 | E2SM-NI “Network Interface” is used to define the services exposed by a RAN function which performs the following functionalities:<br><ul style="list-style-type: none"> <li>- Exposure of Network Interfaces</li> <li>- Modification of both incoming and outgoing network interface message contents</li> <li>- Execution of policies that may result in change of network behavior</li> </ul> | +| E2SM-KPM version1<br>O-RAN<br>WG3.TS.E2SM-KPM [5] | iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version1 (1) e2sm(2) e2sm-KPMMON-IEs (2) | ASN.1 | E2SM-KPM “KPM Monitor” (version1) is used to define the services exposed by a RAN function which performs the following functionalities:<br><ul style="list-style-type: none"> <li>- Exposure of O-DU's cell related performance IEs through periodic KPM Report.</li> <li>- Exposure of O-CU-CP's cell/UE related performance IEs through periodic KPM Report.</li> <li>- Exposure of O-CU-UP's bearer related performance IEs through periodic KPM Report</li> </ul> | +| E2SM-KPM version2<br>O-RAN<br>WG3.TS.E2SM-KPM [5] | iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version2 (2) e2sm(2) e2sm-KPMMON-IEs (2) | ASN.1 | E2SM-KPM “KPM Monitor” (version2) is used to define the services exposed by a RAN function which performs the following functionalities:<br><ul style="list-style-type: none"> <li>- Exposure of available measurements from O-DU, O-CU-CP, and/or O-CU-UP via the RAN Function Definition IE.</li> <li>- Periodic reporting of measurements subscribed from Near-RT RIC.</li> </ul> | +| E2SM-RC<br>O-RAN<br>WG3.TS.E2SM-RC [19] | iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version1 (1) e2sm(2) e2sm-RC-IEs (3) | ASN.1 | E2SM-RC “RAN Control” is used to define the services exposed by a RAN function which performs the following functionalities:<br><ul style="list-style-type: none"> <li>- Exposure of RAN control and UE context related information.</li> <li>- Modification and initiation of RAN control related call processes and messages</li> <li>- Execution of policies that may result in change of RAN control behavior</li> </ul> | +| E2SM-CCC<br>O-RAN<br>WG3.TS.E2SM-CCC [20] | iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version1 (1) e2sm(2) e2sm-CCC-IEs (4) | JSON | E2SM-CCC “Cell Configuration and Control” is used to define the services exposed by a RAN function which performs the following functionalities:<br><ul style="list-style-type: none"> <li>- Exposure of node level and cell level configuration information</li> <li>- Initiate control and/or configuration of node level and cell level parameters</li> </ul> | +| E2SM-LLC<br>O-RAN<br>WG3.TS.E2SM-LLC [22] | iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version1(1) e2sm(2) e2sm-LLC-IEs(5) | ASN.1 | E2SM-LLC “Lower Layers Control” is used to define the services exposed by a RAN function which performs the following functionalities:<br><ul style="list-style-type: none"> <li>- Exposure of L1 and L2 information</li> <li>- Initiate control and/or configuration of L1 and L2 parameters</li> </ul> | + +# 6 Common Information Elements for E2SM Service Models + +## 6.1 General + +Clause 6.2 presents the individual Information Elements that may be adopted by any specific E2SM including the specifications listed in table 5-1. Clause 6.3 provides the corresponding ASN.1 definition of each Information Element, this module may be associated with the ASN.1 definitions in a specific E2SM specification using the ASN.1 "Import" instruction. + +The following attributes are used for the tabular description of the messages and information elements: + +NOTE: The messages have been defined in accordance with the guidelines specified in 3GPP TR 25.921 [i.2]. + +## 6.2 Information Element definitions + +### 6.2.1 General + +When specifying information elements which are to be represented by bit strings, if not otherwise specifically stated in the semantics description of the concerned IE or elsewhere, the following principle applies with regards to the ordering of bits: + +- The first bit (leftmost bit) contains the Most Significant Bit (MSB). +- The last bit (rightmost bit) contains the Least Significant Bit (LSB). +- When importing bit strings from other specifications, the first bit of the bit string contains the first bit of the concerned information. + +### 6.2.2 E2SM common IEs + +#### 6.2.2.1 RAN Function Name + +This IE defines the name of a given *RAN Function Name* IE as a structured data. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|-------|----------------------------------------|--------------------------------------------------------------------------------------------------| +| RAN Function Short Name | M | | PrintableString(SIZE(1..150,...)) | Suitable unique short name. | +| RAN Function Service Model<br>OID | M | | PrintableString(SIZE(1..1000,...)<br>) | Object Identifier of this specific E2SM. Formatted as per OID. | +| RAN Function Description | M | | PrintableString(SIZE(1..150,...)) | Suitable text describing scope of E2SM. | +| RAN Function Instance | O | | INTEGER | Suggested when E2 Node declares multiple RAN Function ID supporting the same E2SM specification. | + +#### 6.2.2.2 RIC Style Type + +This IE defines the identifier of a given RIC Style. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------|-----------------------| +| RIC Style Type | M | | INTEGER | | + +#### 6.2.2.3 RIC Style Name + +This IE defines the name of a given RIC Style. + +The same E2SM may support more than one Style for each RIC Service. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------------------|-----------------------| +| RIC Style Name | M | | PrintableString(SIZE(1..150,...)) | | + +#### 6.2.2.4 RIC Format Type + +This IE defines the identifier of a given RIC Format. + +The same E2SM may support more than one encoding Formats for each E2AP IE and each E2AP IE message encoding Format may be used by one or more RIC Service Styles. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------|----------|-------|-----------------------|-----------------------| +| RIC Format Type | M | | INTEGER | | + +#### 6.2.2.5 Cell Global ID + +This IE is used to globally identify a cell in an E2 Node. The IE is derived from 3GPP TS 38.423 [7] clause 9.2.3.25 "Target Cell Global ID". + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE <i>RAT type</i> | M | | | | +| >NR | | | | | +| >>NR CGI | M | | 6.2.3.7 | | +| >E-UTRA | | | | | +| >>E-UTRA CGI | M | | 6.2.3.11 | | + +#### 6.2.2.6 UE ID + +This IE contains the O-RAN agreed UE ID data structure to be used on E2 interface. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------|-----------------------|---------------------|-----------------------|-----------------------------------------------------------------------------------| +| CHOICE <i>UEID case</i> | M | | | | +| >gNB | | | | E2 Node of type gNB when connected to 5GC. | +| >>AMF UE NGAP ID | M | | 6.2.3.16 | | +| >>GUAMI | M | | 6.2.3.17 | | +| >>gNB-CU UE F1AP ID List | C-<br>ifCUDUseparated | | | More than 1 F1AP ID shall be reported by E2 Node only when NR-DC is established. | +| >>>gNB-CU UE F1AP ID Item | | 1 ..<br><maxF1APId> | | | +| >>>>gNB-CU UE F1AP ID | M | | 6.2.3.21 | | +| >>gNB-CU-CP UE E1AP ID List | C-<br>ifCPUPseparated | | | | +| >>>gNB-CU-CP UE E1AP ID Item | | 1 ..<br><maxE1APId> | | | +| >>>>gNB-CU-CP UE E1AP ID | M | | 6.2.3.20 | | +| >>RAN UE ID | O | | 6.2.3.25 | | +| >>M-NG-RAN node UE XnAP ID | C-<br>ifDCSetup | | 6.2.3.19 | To be reported by both MN and SN. | +| >>Global gNB ID | O | | 6.2.3.3 | This IE shall not be used. <i>Global NG-RAN Node ID</i> IE shall replace this IE. | +| >>Global NG-RAN Node ID | C-<br>ifDCSetup | | 6.2.3.2 | To be reported only by SN. | +| >>Cell RNTI | O | | 6.2.2.17 | | +| >gNB-DU / en-gNB-DU | | | | E2 node of type gNB-DU. | +| >>gNB-CU UE F1AP ID | M | | 6.2.3.21 | | +| >>RAN UE ID | O | | 6.2.3.25 | | +| >>Cell RNTI | O | | 6.2.2.17 | | +| >gNB-CU-UP / en-gNB-CU-UP | | | | E2 node of type gNB-CU-UP. | +| >>gNB-CU-CP UE E1AP ID | M | | 6.2.3.20 | | +| >>RAN UE ID | O | | 6.2.3.25 | | +| >ng-eNB | | | | E2 Node of type ng-eNB when connected to 5GC. | +| >>AMF UE NGAP ID | M | | 6.2.3.16 | | +| >>GUAMI | M | | 6.2.3.17 | | +| >>ng-eNB-CU UE W1AP ID | C-<br>ifCUDUseparated | | 6.2.3.22 | | +| >>M-NG-RAN node UE XnAP ID | C-<br>ifDCSetup | | 6.2.3.19 | To be reported by both MN and SN. | +| >>Global ng-eNB ID | O | | 6.2.3.8 | This IE shall not be used. <i>Global NG-RAN Node ID</i> IE shall replace this IE. | +| >>Global NG-RAN Node ID | C-<br>ifDCSetup | | 6.2.3.2 | To be reported only by SN. | +| >>Cell RNTI | O | | 6.2.2.17 | | +| >ng-eNB-DU | | | | E2 node of type ng-eNB-DU. | +| >> ng-eNB-CU UE W1AP ID | M | | 6.2.3.22 | | + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------|-------------------|-------------------------------|-----------------------|------------------------------------------------------------------------| +| >>Cell RNTI | O | | 6.2.2.17 | | +| >en-gNB | | | | E2 Node of type en-gNB when connected to EPC and EN-DC is established. | +| >>MeNB UE X2AP ID | M | | 6.2.3.23 | | +| >>MeNB UE X2AP ID Extension | O | | 6.2.3.24 | | +| >>Global eNB ID | M | | 6.2.3.9 | | +| >>gNB-CU UE F1AP ID | C-ifCUDUseparated | | 6.2.3.21 | | +| >>gNB-CU-CP UE E1AP ID List | C-ifCPUPseparated | | | | +| >>>gNB-CU UE E1AP ID Item | | 1 .. <i><maxE1APId></i> | | | +| >>>>gNB-CU-CP UE E1AP ID | M | | 6.2.3.20 | | +| >> RAN UE ID | O | | 6.2.3.25 | | +| >>Cell RNTI | O | | 6.2.2.17 | | +| >eNB | | | | E2 Node of type eNB when connected to EPC. | +| >>MME UE S1AP ID | M | | 6.2.3.26 | | +| >>GUMMEI | M | | 6.2.3.18 | | +| >>MeNB UE X2AP ID | C-ifDCSetup | | 6.2.3.23 | To be reported by MeNB and SeNB. | +| >>MeNB UE X2AP ID Extension | C-ifDCSetup | | 6.2.3.24 | To be reported by MeNB and SeNB. | +| >>Global eNB ID | C-ifDCSetup | | 6.2.3.9 | To be reported only by SeNB. | +| >>Cell RNTI | O | | 6.2.2.17 | | + +| Range bound | Explanation | +|------------------|-----------------------------------------------------------------------------| +| <i>maxF1APId</i> | Maximum number of F1AP UEID for a NR-NR DC is 4. | +| <i>maxE1APId</i> | Maximum number of E1AP UEID for UE connected with different CU-UP is 65535. | + +| Condition | Explanation | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| ifDCSetup | This IE shall be present in messages from E2 Node to NearRT-RIC if DC is established, whereas from NearRT-RIC to E2 Node messages, this IE may not be included. | +| ifCUDUseparated | This IE shall be present in messages from E2 Node to NearRT-RIC for a CU-DU separated ng-eNB or (en-)gNB, whereas from NearRT-RIC to E2 Node messages, this IE may not be included. | +| ifCPUPseparated | This IE shall be present in messages from E2 Node to NearRT-RIC for a CP-UP separated (en-)gNB, whereas from NearRT-RIC to E2 Node messages, this IE may not be included. | + +#### 6.2.2.7 Group ID + +This IE defines a generic "Group ID" suitable for both EPC and 5GC networks. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE <i>Core type</i> | M | | | | +| >5GC | | | | | +| >>IRFSP | M | | 6.2.3.27 | | +| >EPC | | | | | +| >>SPID | M | | 6.2.3.28 | | + +#### 6.2.2.8 Core CP ID + +This IE defines a generic "Core CP ID" suitable for both EPC and 5GC networks. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE <i>Core type</i> | M | | | | +| >5GC | | | | | +| >>GUAMI | M | | 6.2.3.17 | | +| >EPC | | | | | +| >>GUMMEI | M | | 6.2.3.18 | | + +#### 6.2.2.9 QoS ID + +This IE defines a generic "QoS ID" suitable for both EPC and 5GC networks. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE <i>Core type</i> | M | | | | +| >5GC | | | | | +| >>5QI | M | | 6.2.3.13 | | +| >EPC | | | | | +| >>QCI | M | | 6.2.3.14 | | + +#### 6.2.2.10 Network Interface Type + +This IE defines the type of a standardized Network Interface. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|----------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Interface Type | M | | ENUMERATED (NG, Xn, F1, E1, S1, X2, W1, ...) | NG refers to NG interface 3GPP TS 38.413 [6].<br>Xn refers to Xn interface 3GPP TS 38.423 [7].<br>F1 refers to F1 interface 3GPP TS 38.473 [8].<br>E1 refers to E1 interface 3GPP TS 37.483 [9].<br>S1 refers to S1 interface 3GPP TS 36.413 [10].<br>X2 refers to X2 interface 3GPP TS 36.423 [11].<br>W1 refers to W1 interface 3GPP TS 37.473 [12]. | + +#### 6.2.2.11 Network Interface Identifier + +This IE defines the identifier of the network node terminating a specific network interface. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------|----------|-------|-----------------------|--------------------------------------------| +| <b>CHOICE</b> <i>Interface Identifier</i> | M | | | | +| >NG | | | | For interface type NG 3GPP TS 38.413 [6]. | +| >>GUAMI | M | | 6.2.3.17 | | +| >Xn | | | | For interface type Xn 3GPP TS 38.423 [7]. | +| >>Global NG-RAN Node ID | M | | 6.2.3.2 | | +| >F1 | | | | For interface type F1 3GPP TS 38.473 [8]. | +| >>Global gNB ID | M | | 6.2.3.2 | | +| >>gNB-DU ID | M | | 6.2.3.6 | | +| >E1 | | | | For interface type E1 3GPP TS 37.483 [9]. | +| >>Global gNB ID | M | | 6.2.3.2 | | +| >>gNB-CU-UP ID | M | | 6.2.3.5 | | +| >S1 | | | | For interface type S1 3GPP TS 36.413 [10]. | +| >>GUMMEI | M | | 6.2.3.18 | | +| >X2 | | | | For interface type X2 3GPP TS 36.423 [11]. | +| >> <b>CHOICE</b> <i>Node Type</i> | M | | | | +| >>>Global eNB ID | | | 6.2.3.9 | For eNB. | +| >>>Global en-gNB ID | | | 6.2.3.4 | For en-gNB. | +| >W1 | | | | For interface type W1 3GPP TS 37.473 [12]. | +| >>Global ng-eNB ID | M | | 6.2.3.8 | | +| >>ng-eNB-DU ID | M | | 6.2.3.10 | | + +#### 6.2.2.12 Network Interface Message ID + +This IE defines the identifier for a specific message of a given Network Interface. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------------------------------------------------------------------------|----------------------------| +| Interface Procedure ID | M | | INTEGER | Elementary Procedure Code. | +| Message Type | M | | ENUMERATED<br>(InitiatingMessage,<br>SuccessfulOutcome,<br>UnsuccessfulOutcome,<br>...) | | + +#### 6.2.2.13 RRC Message ID + +This IE defines the identifier for a specific RRC message defined in either 3GPP TS 36.331 [14] or 3GPP TS 38.331 [15]. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|---------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------| +| <b>CHOICE RRC Type</b> | M | | | | +| >LTE | | | | | +| >>LTE RRC Class | M | | ENUMERATED (BCCH-BCH, BCCH-BCH-MBMS, BCCH-DL-SCH, BCCH-DL-SCH-BR, BCCH-DL-SCH-MBMS, MCCH, PCCH, DL-CCCH, DL-DCCH, UL-CCCH, UL-DCCH, SC-MCCH, ...) | Refers to RRC message class defined in 3GPP TS 36.331 [14] clause 6.2.1. | +| >NR | | | | | +| >>NR RRC Class | M | | ENUMERATED (BCCH-BCH, BCCH-DL-SCH, DL-CCCH, DL-DCCH, PCCH, UL-CCCH, UL-CCCH1, UL-DCCH, ...) | Refers to RRC message class defined in 3GPP TS 38.331 [15] clause 6.2.1. | +| RRC Message ID | M | | INTEGER | Number starts from 0 from the first entry of a given RRC message class defined in 3GPP TS 36.331 [14] or TS 38.331 [15]. | + +#### 6.2.2.14 Serving Cell PCI + +This IE is used to identify the serving cell PCI in an E2 Node. The IE is derived from 3GPP TS 38.473 [8] clause 9.3.1.10 and 3GPP TS 36.423 [11] clause 9.2.8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE RAT type</b> | M | | | | +| >NR | | | | | +| >>NR PCI | M | | 6.2.3.29 | | +| >E-UTRA | | | | | +| >>E-UTRA PCI | M | | 6.2.3.32 | | + +#### 6.2.2.15 Serving Cell ARFCN + +This IE is used to identify the serving cell ARFCN in an E2 Node. The IE is derived from 3GPP TS 38.473 [8] clause 9.3.1.17 and 3GPP TS 36.423 [11] clause 9.2.26. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE RAT type</b> | M | | | | +| >NR | | | | | +| >>NR ARFCN | M | | 6.2.3.30 | | +| >E-UTRA | | | | | +| >>EARFCN | M | | 6.2.3.33 | | + +#### 6.2.2.16 Beam ID + +This IE is used to identify the generic "Beam ID" suitable for NR Radio Access Technology (RAT). + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------|-------------------------------------------------| +| CHOICE RAT | M | | | | +| >NR | | | | | +| >>NR SSB-index | M | | 6.2.3.36 | SSB-Index is used in NR as the Beam identifier. | + +#### 6.2.2.17 Cell RNTI + +This represents a temporary UE Identifier in a cell in a Radio Network. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------|----------------------------------------------------| +| C-RNTI | M | | 6.2.3.37 | | +| Cell Global ID | M | | 6.2.2.5 | Identifies the cell where the C-RNTI is generated. | + +#### 6.2.2.18 Partial UE ID + +This IE contains the UE ID data structure to be used for communication from Near-RT RIC to E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|-------|-----------------------|-----------------------| +| AMF UE NGAP ID | O | | 6.2.3.16 | | +| GUAMI | O | | 6.2.3.17 | | +| gNB-CU UE F1AP ID | O | | 6.2.3.21 | | +| gNB-CU-CP UE E1AP ID | O | | 6.2.3.20 | | +| RAN UE ID | O | | 6.2.3.25 | | +| M-NG-RAN node UE XnAP ID | O | | 6.2.3.19 | | +| Global NG-RAN Node ID | O | | 6.2.3.2 | | +| Cell RNTI | O | | 6.2.2.17 | | +| ng-eNB-CU UE W1AP ID | O | | 6.2.3.22 | | +| MeNB UE X2AP ID | O | | 6.2.3.23 | | +| MeNB UE X2AP ID Extension | O | | 6.2.3.24 | | +| Global eNB ID | O | | 6.2.3.9 | | +| MME UE S1AP ID | O | | 6.2.3.26 | | +| GUMMEI | O | | 6.2.3.18 | | + +### 6.2.3 3GPP derived IEs + +#### 6.2.3.1 PLMN Identity + +This IE indicates the PLMN Identity. + +Derived from 3GPP TS 38.413 [6] clause 9.3.3.5. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|------------------------|-----------------------------------------------| +| PLMN Identity | M | | OCTET STRING (SIZE(3)) | Defined in 3GPP TS 38.413 [6] clause 9.3.3.5. | + +#### 6.2.3.2 Global NG-RAN Node ID + +This IE is used to globally identify an NG-RAN node of gNB and ng-eNB cases only. + +Derived from 3GPP TS 38.423 [7] clause 9.2.2.3. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE <i>NG-RAN node</i> | M | | | | +| > <i>gNB</i> | | | | | +| >>Global gNB ID | M | | 6.2.3.3 | | +| > <i>ng-eNB</i> | | | | | +| >>Global ng-eNB ID | M | | 6.2.3.8 | | + +#### 6.2.3.3 Global gNB ID + +This IE is used to globally identify a gNB. + +Derived from 3GPP TS 38.413 [6] clause 9.3.1.6. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|---------------------------|-----------------------------------------------| +| PLMN Identity | M | | 6.2.3.1 | | +| CHOICE <i>gNB ID</i> | M | | | | +| > <i>gNB ID</i> | | | | | +| >>gNB ID | M | | BIT STRING (SIZE(22..32)) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.6. | + +#### 6.2.3.4 Global en-gNB ID + +This IE is used to globally identify an en-gNB. + +Derived from 3GPP TS 36.423 [11] clause 9.2.112. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|---------------------------|------------------------------------------------| +| PLMN Identity | M | | 6.2.3.1 | | +| CHOICE <i>en-gNB ID</i> | M | | | | +| > <i>en-gNB ID</i> | | | | | +| >>en-gNB ID | M | | BIT STRING (SIZE(22..32)) | Defined in 3GPP TS 36.423 [11] clause 9.2.112. | + +#### 6.2.3.5 gNB-CU-UP ID + +This IE uniquely identifies the gNB-CU-UP at least within a gNB-CU-CP. + +Derived from 3GPP TS 37.483 [9] clause 9.3.1.15. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|----------------------------|------------------------------------------------| +| gNB-CU-UP ID | M | | INTEGER (0 .. $2^{36}-1$ ) | Defined in 3GPP TS 37.483 [9] clause 9.3.1.15. | + +#### 6.2.3.6 gNB-DU ID + +This IE uniquely identifies the gNB-DU at least within a gNB-CU. + +Derived from 3GPP TS 38.473 [8] clause 9.3.1.9. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|----------------------------|-----------------------------------------------| +| gNB-DU ID | M | | INTEGER (0 .. $2^{36}-1$ ) | Defined in 3GPP TS 38.473 [8] clause 9.3.1.9. | + +#### 6.2.3.7 NR CGI + +This IE is used to globally identify an NR cell. + +Derived from 3GPP TS 38.413 [6] clause 9.3.1.7. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|-----------------------|-----------------------------------------------| +| PLMN Identity | M | | 6.2.3.1 | | +| NR Cell Identity | M | | BIT STRING (SIZE(36)) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.7. | + +#### 6.2.3.8 Global ng-eNB ID + +This IE is used to globally identify an ng-eNB. + +Derived from 3GPP TS 38.413 [6] clause 9.3.1.8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|-------|-----------------------|-----------------------------------------------| +| PLMN Identity | M | | 6.2.3.1 | | +| CHOICE <i>ng-eNB ID</i> | M | | | | +| > <i>Macro ng-eNB ID</i> | | | | | +| >>Macro ng-eNB ID | M | | BIT STRING (SIZE(20)) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.8. | +| > <i>Short Macro ng-eNB ID</i> | | | | | +| >>Short Macro ng-eNB ID | M | | BIT STRING (SIZE(18)) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.8. | +| > <i>Long Macro ng-eNB ID</i> | | | | | +| >>Long Macro ng-eNB ID | M | | BIT STRING (SIZE(21)) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.8. | + +#### 6.2.3.9 Global eNB ID + +This IE is used to globally identify an eNB. + +Derived from 3GPP TS 36.413 [10] clause 9.2.1.37. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------|----------|-------|-----------------------|-------------------------------------------------| +| PLMN Identity | M | | 6.2.3.1 | | +| CHOICE eNB ID | M | | | | +| >Macro eNB ID | | | | | +| >>Macro eNB ID | M | | BIT STRING (SIZE(20)) | Defined in 3GPP TS 36.413 [10] clause 9.2.1.37. | +| >Home eNB ID | | | | | +| >>Home eNB ID | M | | BIT STRING (SIZE(28)) | Defined in 3GPP TS 36.413 [10] clause 9.2.1.37. | +| >Short Macro eNB ID | | | | | +| >> Short Macro eNB ID | M | | BIT STRING (SIZE(18)) | Defined in 3GPP TS 36.413 [10] clause 9.2.1.37. | +| >Long Macro eNB ID | | | | | +| >> Long Macro eNB ID | M | | BIT STRING (SIZE(21)) | Defined in 3GPP TS 36.413 [10] clause 9.2.1.37. | + +#### 6.2.3.10 ng-eNB-DU ID + +This IE uniquely identifies the ng-eNB-DU at least within an ng-eNB-CU. + +Derived from 3GPP TS 37.473 [12] clause 9.3.1.9. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|----------------------------|------------------------------------------------| +| ng-eNB-DU ID | M | | INTEGER (0 .. $2^{36}-1$ ) | Defined in 3GPP TS 37.473 [12] clause 9.3.1.9. | + +#### 6.2.3.11 E-UTRA CGI + +This IE is used to globally identify an E-UTRA cell. + +Derived from 3GPP TS 38.413 [6] clause 9.3.1.9. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|-----------------------|-----------------------------------------------| +| PLMN Identity | M | | 6.2.3.1 | | +| E-UTRA Cell Identity | M | | BIT STRING (SIZE(28)) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.9. | + +#### 6.2.3.12 S-NSSAI + +This IE is used to indicate the S-NSSAI. + +Derived from 3GPP TS 38.413 [6] clause 9.3.1.24. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|------------------------|------------------------------------------------| +| SST | M | | OCTET STRING (SIZE(1)) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.24. | +| SD | O | | OCTET STRING (SIZE(3)) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.24. | + +#### 6.2.3.13 5QI + +This IE is used to indicate 5QI value. + +Derived from 3GPP TS 38.413 [6] clause 9.3.1.28. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|------------------------------------------------| +| 5QI | M | | INTEGER (0..255, ...) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.28. | + +#### 6.2.3.14 QCI + +This IE is used to indicate QCI value. + +Derived from 3GPP TS 36.413 [10] clause 9.2.1.15. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|-------------------------------------------------| +| QCI | M | | INTEGER (0..255) | Defined in 3GPP TS 36.413 [10] clause 9.2.1.15. | + +#### 6.2.3.15 QoS Flow Identifier (QFI) + +This IE identifies a QoS flow within a PDU Session. + +Derived from 3GPP TS 38.413 [6] clause 9.3.1.51. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-----------------------|------------------------------------------------| +| QoS Flow Identifier | M | | INTEGER (0..63, ...) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.51. | + +#### 6.2.3.16 AMF UE NGAP ID + +This IE uniquely identifies a UE over the NG interface within a NG-RAN node. + +Derived from 3GPP TS 38.413 [6] clause 9.3.3.1. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|---------------------------------|-----------------------------------------------| +| AMF UE NGAP ID | M | | INTEGER (0..2 <sup>40</sup> -1) | Defined in 3GPP TS 38.413 [6] clause 9.3.3.1. | + +#### 6.2.3.17 GUAMI + +This IE indicates the AMF identity. + +Derived from 3GPP TS 38.413 [6] clause 9.3.3.3. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|--------------------------|---------------------------------------------------| +| PLMN Identity | M | | 6.2.3.1 | | +| AMF Region ID | M | | BIT STRING<br>(SIZE(8)) | | +| AMF Set ID | M | | BIT STRING<br>(SIZE(10)) | Defined in 3GPP TS 38.413 [6]<br>clause 9.3.3.12. | +| AMF Pointer | M | | BIT STRING<br>(SIZE(6)) | Defined in 3GPP TS 38.413 [6]<br>clause 9.3.3.19. | + +#### 6.2.3.18 GUMMEI + +This IE indicates the globally unique MME identity. + +Derived from 3GPP TS 36.413 [10] clause 9.2.3.9. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|----------------------------|-------------------------------------------------------| +| PLMN Identity | M | | 6.2.3.1 | | +| MME Group ID | M | | OCTET STRING<br>(SIZE(2)) | | +| MME code | M | | OCTET STRING<br>(SIZE (1)) | Defined in 3GPP TS<br>36.413 [10] clause<br>9.2.3.12. | + +#### 6.2.3.19 NG-RAN Node UE XnAP ID + +This IE uniquely identifies a UE over the Xn interface within a NG-RAN node. + +Derived from 3GPP TS 38.423 [7] clause 9.2.3.16. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|----------------------------|---------------------------------------------------| +| NG-RAN node UE XnAP ID | M | | INTEGER (0 .. $2^{32}-1$ ) | Defined in 3GPP TS 38.423<br>[7] clause 9.2.3.16. | + +#### 6.2.3.20 gNB-CU-CP UE E1AP ID + +This IE uniquely identifies a UE over the E1 interface within a gNB-CU-CP. + +Derived from 3GPP TS 37.483 [9] clause 9.3.1.4. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|-------------------------------|--------------------------------------------------| +| gNB-CU-CP UE E1AP ID | M | | INTEGER<br>(0 .. $2^{32}-1$ ) | Defined in 3GPP TS 37.483 [9]<br>clause 9.3.1.4. | + +#### 6.2.3.21 gNB-CU UE F1AP ID + +This IE uniquely identifies a UE over the F1 interface within a gNB-CU. + +Derived from 3GPP TS 38.473 [8] clause 9.3.1.4. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------|----------|-------|-------------------------------|--------------------------------------------------| +| gNB-CU UE F1AP ID | M | | INTEGER<br>(0 .. $2^{32}-1$ ) | Defined in 3GPP TS 38.473 [8]<br>clause 9.3.1.4. | + +#### 6.2.3.22 ng-eNB-CU UE W1AP ID + +This IE uniquely identifies a UE over the W1 interface within an ng-eNB-CU. + +Derived from 3GPP TS 37.473 [12] clause 9.3.1.4. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|----------------------------|------------------------------------------------| +| ng-eNB-CU UE W1AP ID | M | | INTEGER (0 .. $2^{32}-1$ ) | Defined in 3GPP TS 37.473 [12] clause 9.3.1.4. | + +#### 6.2.3.23 eNB UE X2AP ID + +This IE, combined with the eNB UE X2AP ID Extension when present regardless its value, uniquely identifies a UE over the X2 interface within an eNB. + +Derived from 3GPP TS 36.423 [11] clause 9.2.24. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------|-----------------------------------------------| +| eNB UE X2AP ID | M | | INTEGER (0..4095) | Defined in 3GPP TS 36.423 [11] clause 9.2.24. | + +#### 6.2.3.24 eNB UE X2AP ID Extension + +This IE, combined with the eNB UE X2AP ID uniquely identifies a UE over the X2 interface within an eNB. If the setup of an UE associated signalling connection was initiated including the eNB UE X2AP ID Extension, the eNB UE X2AP ID Extension shall be used by both peers for the life-time of the respective UE-associated signalling connection. + +Derived from 3GPP TS 36.423 [11] clause 9.2.86. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------|----------|-------|------------------------|-----------------------------------------------| +| eNB UE X2AP ID Extension | M | | INTEGER (0..4095, ...) | Defined in 3GPP TS 36.423 [11] clause 9.2.86. | + +#### 6.2.3.25 RAN UE ID + +This UE Identifier identifies an UE over E1 and F1 interface within a gNB. + +Derived from 3GPP TS 38.473 [8] clause 9.2.2.1. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-------------------------|-----------------------------------------------| +| RAN UE ID | O | | OCTET STRING (SIZE (8)) | Defined in 3GPP TS 38.473 [8] clause 9.2.2.1. | + +#### 6.2.3.26 MME UE S1AP ID + +This IE uniquely identifies a UE over the S1 interface within a MME. + +Derived from 3GPP TS 36.413 [10] clause 9.2.3.3. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------------------|------------------------------------------------| +| MME UE S1AP ID | M | | INTEGER (0 .. 2 <sup>32</sup> -1) | Defined in 3GPP TS 36.413 [10] clause 9.2.3.3. | + +#### 6.2.3.27 Index to RAT/Frequency Selection Priority (IRFSP) + +This IE is used to define local configuration for RRM strategies such as camp priorities in Idle mode and control of inter-RAT/inter-frequency handover in Active mode. + +Derived from 3GPP TS 38.413 [6] clause 9.3.1.61. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------|----------|-------|-----------------------|------------------------------------------------| +| Index to RAT/Frequency Selection Priority | M | | INTEGER (1..256, ...) | Defined in 3GPP TS 38.413 [6] clause 9.3.1.61. | + +#### 6.2.3.28 Subscriber Profile ID for RAT/Frequency priority (SPID) + +This IE is used to define camp priorities in Idle mode and to control inter-RAT/inter-frequency handover in Active mode. + +Derived from 3GPP TS 36.413 [10] clause 9.2.1.39. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------------|----------|-------|-----------------------|-------------------------------------------------| +| Subscriber Profile ID for RAT/Frequency Priority | M | | INTEGER (1..256) | Defined in 3GPP TS 36.413 [10] clause 9.2.1.39. | + +#### 6.2.3.29 NR PCI + +This IE is used to identify an NR cell PCI. + +Derived from 3GPP TS 38.473 [8] clause 9.3.1.10. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|--------------------------------------------------| +| NR PCI | M | | INTEGER (0.. 1007) | Derived from 3GPP TS 38.473 [8] clause 9.3.1.10. | + +#### 6.2.3.30 NR ARFCN + +This IE is used to identify an NR ARFCN. + +Derived from 3GPP TS 38.473 [8] clause 9.3.1.17. + +| IE/Group Name | Presence | Range | IE Type and Reference | Semantics Description | +|---------------|----------|-------|-------------------------|--------------------------------------------------| +| NR ARFCN | M | | INTEGER (0..maxNRARFCN) | Derived from 3GPP TS 38.473 [8] clause 9.3.1.17. | + +| Range bound | Explanation | +|-------------|-----------------------------------------------| +| maxNRARFCN | Maximum value of NR ARFCNs. Value is 3279165. | + +#### 6.2.3.31 5GS TAC + +This IE is used to identify 5GS Tracking Area Code. + +Defined in 3GPP TS 38.473 [8] clause 9.3.1.29. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-------------------------|------------------------------------------------| +| 5GS TAC | M | | OCTET STRING (SIZE (3)) | Defined in 3GPP TS 38.473 [8] clause 9.3.1.29. | + +#### 6.2.3.32 E-UTRA PCI + +This IE is used to identify an E-UTRA cell PCI. + +Derived from 3GPP TS 36.423 [11] clause 9.2.8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|------------------------|------------------------------------------------| +| E-UTRA PCI | M | | INTEGER (0.. 503, ...) | Derived from 3GPP TS 36.423 [11] clause 9.2.8. | + +#### 6.2.3.33 E-UTRA ARFCN + +This IE is used to identify an E-UTRA Frequency Info. + +Defined in 3GPP TS 36.423 [11] clause 9.2.26. + +| IE/Group Name | Presence | Range | IE Type and Reference | Semantics Description | +|---------------|----------|-------|-------------------------|-----------------------------------------------| +| EARFCN | M | | INTEGER (0.. maxEARFCN) | Defined in 3GPP TS 36.423 [11] clause 9.2.26. | + +| Range bound | Explanation | +|-------------|-------------------------------------------| +| maxEARFCN | Maximum value of EARFCNs. Value is 65535. | + +#### 6.2.3.34 E-UTRA TAC + +This IE is used to identify an E-UTRA Tracking Area Code. + +Derived from 3GPP TS 36.423 [11] clause 9.2.8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|------------------------|------------------------------------------------| +| E-UTRA TAC | M | | OCTET STRING (SIZE(2)) | Derived from 3GPP TS 36.423 [11] clause 9.2.8. | + +#### 6.2.3.35 NR Frequency Info + +This IE is used to define the carrier frequency and bands used in a cell. + +Derived from 3GPP TS 38.473 [8] clause 9.3.1.17. + +| IE/Group Name | Presence | Range | IE Type and Reference | Semantics Description | +|----------------------------|----------|-------------------------------|-------------------------------|------------------------------------------------| +| NR ARFCN | M | | 6.2.3.30 | | +| NR Frequency Band List | | 1 | | | +| >NR Frequency Band Item | | 1.. <i>maxnoofNRCellBands</i> | | | +| >>NR Frequency Band | M | | INTEGER (1.. 1024, ...) | Defined in 3GPP TS 38.473 [8] clause 9.3.1.17. | +| >>Supported SUL band List | | 0.. <i>maxnoofNRCellBands</i> | | | +| >>>Supported SUL band Item | M | | INTEGER (1.. 1024, ...) | Defined in 3GPP TS 38.473 [8] clause 9.3.1.17. | +| NRFrequency Shift 7p5khz | O | | ENUMERATED (false, true, ...) | Defined in 3GPP TS 38.473 [8] clause 9.3.1.17. | + +| Range bound | Explanation | +|--------------------|----------------------------------------------------------------------| +| maxnoofNRCellBands | Maximum no. of frequency bands supported for a NR cell. Value is 32. | + +#### 6.2.3.36 NR SSB-Index + +This IE is used to identify the NR SSB-Index. + +Derived from 3GPP TS 38.331 [15] clause 6.3.2. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------------|------------------------------------------------| +| SSB-Index | M | | INTEGER (0.. maxNrofSSBs-1) | Derived from 3GPP TS 38.331 [15] clause 6.3.2. | + +| Range bound | Explanation | +|---------------|-------------------------------------------------------------------------| +| maxNrofSSBs-1 | Maximum number of SSB resources in a resource set minus 1. Value is 63. | + +#### 6.2.3.37 C-RNTI + +This represents a temporary UE Identifier in a cell in a Radio Network. + +Derived from 3GPP TS 38.331 [15] clause 6.3.2. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|----------------------------------------------| +| C-RNTI | M | | INTEGER (0..65535) | Defined in 3GPP TS 38.331 [15] clause 6.3.2. | + +## 6.3 Information Element Abstract Syntax (with ASN.1) + +### 6.3.1 General + +E2SM ASN.1 definition conforms to ITU-T Rec. X.680 [16] and ITU-T Rec. X.681 [17]. + +Clause 6.3.2 presents the Abstract Syntax of the common E2SM information elements that may be used with RAN Function specific O-RAN WG3.TS.E2AP [3] Information Elements when encoded using ASN.1. In case there is contradiction between the ASN.1 definition in this clause and the tabular format in clause 6.2, the ASN.1 shall take precedence, except for the definition of conditions for the presence of conditional elements, in which the tabular format shall take precedence. + +### 6.3.2 Information Element definitions + +``` +-- ASN1START +-- ***** +-- E2SM +-- Information Element Definitions +-- +-- ***** + +E2SM-COMMON-IEs { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version1(1) +e2sm(2) e2sm-COMMON-IEs(0) } + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +-- ----- + +-- Constants + +-- ----- + +maxElAPid INTEGER ::= 65535 +maxFlAPid INTEGER ::= 4 + +-- IEs derived from 3GPP 36.423 (X2AP) +maxEARFCN INTEGER ::= 65535 + +-- IEs derived from 3GPP 38.473 (FlAP) +maxNRARFCN INTEGER ::= 3279165 +maxnoofNrCellBands INTEGER ::= 32 + +-- IEs derived from 3GPP 38.331 (NR RRC) +maxNrofSSBs-1 INTEGER ::= 63 + +-- ----- + +-- E2SM Common IEs + +-- ----- + +Beam-ID ::= CHOICE { + nR-Beam-ID NR-SSB-Index, + ... +} + +Cell-RNTI ::= SEQUENCE { + c-RNTI RNTI-Value, + cell-Global-ID CGI, + ... +} + +CGI ::= CHOICE { + nR-CGI NR-CGI, + eUTRA-CGI EUTRA-CGI, + ... +} +``` + +``` + +CoreCPID ::= CHOICE { + fiveGC GUAMI, + ePC GUMMEI, + ... +} + +InterfaceIdentifier ::= CHOICE { + nG InterfaceID-NG, + xN InterfaceID-Xn, + f1 InterfaceID-F1, + e1 InterfaceID-E1, + s1 InterfaceID-S1, + x2 InterfaceID-X2, + w1 InterfaceID-W1, + ... +} + +InterfaceID-NG ::= SEQUENCE { + guami GUAMI, + ... +} + +InterfaceID-Xn ::= SEQUENCE { + global-NG-RAN-ID GlobalNGRANNodeID, + ... +} + +InterfaceID-F1 ::= SEQUENCE { + globalGNB-ID GlobalGNB-ID, + gNB-DU-ID GNB-DU-ID, + ... +} + +InterfaceID-E1 ::= SEQUENCE { + globalGNB-ID GlobalGNB-ID, + gNB-CU-UP-ID GNB-CU-UP-ID, + ... +} + +InterfaceID-S1 ::= SEQUENCE { + gUMMEI GUMMEI, + ... +} + +InterfaceID-X2 ::= SEQUENCE { + nodeType CHOICE { + global-eNB-ID GlobalENB-ID, + global-en-gNB-ID GlobalenGNB-ID, + ... + }, + ... +} + +InterfaceID-W1 ::= SEQUENCE { + global-ng-eNB-ID GlobalNgENB-ID, + ng-eNB-DU-ID NGENB-DU-ID, + ... +} + +Interface-MessageID ::= SEQUENCE { + interfaceProcedureID INTEGER, + messageType ENUMERATED {initiatingMessage, successfulOutcome, unsuccessfulOutcome, + ...}, + ... +} + +InterfaceType ::= ENUMERATED {nG, xn, f1, e1, s1, x2, w1, ...} + +GroupID ::= CHOICE { + fiveGC FiveQI, + ePC QCI, + ... +} + +PartialUEID ::= SEQUENCE { + amf-UE-NGAP-ID AMF-UE-NGAP-ID + OPTIONAL, + +``` + +``` + + guami GUAMI OPTIONAL, + gNB-CU-UE-F1AP-ID GNB-CU-UE-F1AP-ID OPTIONAL, + gNB-CU-CP-UE-E1AP-ID GNB-CU-CP-UE-E1AP-ID OPTIONAL, + ran-UEID RANUEID OPTIONAL, + m-NG-RAN-UE-XnAP-ID NG-RANnodeUEXnAPID OPTIONAL, + globalNG-RANNode-ID GlobalNGRANNodeID OPTIONAL, + cell-RNTI Cell-RNTI OPTIONAL, + ng-eNB-CU-UE-W1AP-ID NGENB-CU-UE-W1AP-ID OPTIONAL, + m-eNB-UE-X2AP-ID ENB-UE-X2AP-ID OPTIONAL, + m-eNB-UE-X2AP-ID-Extension ENB-UE-X2AP-ID-Extension OPTIONAL, + globalENB-ID GlobaleNB-ID OPTIONAL, + mMME-UE-S1AP-ID MME-UE-S1AP-ID OPTIONAL, + GUMMEI GUMMEI OPTIONAL, + ... +} + +QoSID ::= CHOICE { + fiveGC FiveQI, + ePC QCI, + ... +} + +RANfunction-Name ::= SEQUENCE{ + ranFunction-ShortName PrintableString(SIZE(1..150,...)), + ranFunction-E2SM-OID PrintableString(SIZE(1..1000,...)), + ranFunction-Description PrintableString(SIZE(1..150,...)), + ranFunction-Instance INTEGER OPTIONAL, + ... +} + +RIC-Format-Type ::= INTEGER + +RIC-Style-Type ::= INTEGER + +RIC-Style-Name ::= PrintableString(SIZE(1..150,...)) + +RRC-MessageID ::= SEQUENCE { + rrcType CHOICE { + lte RRCclass-LTE, + nr RRCclass-NR, + ... + }, + messageID INTEGER, + ... +} + +RRCclass-LTE ::= ENUMERATED {bcCH-BCH, bcCH-BCH-MBMS, bcCH-DL-SCH, bcCH-DL-SCH-BR, bcCH-DL-SCH-MBMS, mcCH, +pcCH, dL-CCCH, dL-DCCH, uL-CCCH, uL-DCCH, sC-MCCH, ...} + +RRCclass-NR ::= ENUMERATED {bcCH-BCH, bcCH-DL-SCH, dL-CCCH, dL-DCCH, pcCH, uL-CCCH, uL-CCCH1, uL-DCCH, +...} + +ServingCell-ARFCN ::= CHOICE { + nr NR-ARFCN, + eutra E-UTRA-ARFCN, + ... +} + +ServingCell-PCI ::= CHOICE { + nr NR-PCI, + eutra E-UTRA-PCI, + ... +} + +UEID ::= CHOICE{ + gNB-UEID UEID-GNB, + gNB-DU-UEID UEID-GNB-DU, + gNB-CU-UP-UEID UEID-GNB-CU-UP, + ng-eNB-UEID UEID-NG-ENB, + ng-eNB-DU-UEID UEID-NG-ENB-DU, + en-gNB-UEID UEID-EN-GNB, + eNB-UEID UEID-ENB, + ... +} + +``` + +``` + +UEID-GNB ::= SEQUENCE{ + amf-UE-NGAP-ID AMF-UE-NGAP-ID, + guami GUAMI, + gNB-CU-UE-F1AP-ID-List UEID-GNB-CU-F1AP-ID-List OPTIONAL, + -- C-ifCUDUSeparated: This IE shall be present in messages from E2 Node to NearRT-RIC for a CU-DU + separated gNB, whereas from NearRT-RIC to E2 Node messages, this IE may not be included. More than 1 F1AP + ID shall be reported by E2 Node only when NR-DC is established. + gNB-CU-CP-UE-E1AP-ID-List UEID-GNB-CU-CP-E1AP-ID-List OPTIONAL, + -- C-ifCPUPSeparated: This IE shall be present in messages from E2 Node to NearRT-RIC for a CP-UP + separated gNB, whereas from NearRT-RIC to E2 Node messages, this IE may not be included. + ran-UEID RANUEID OPTIONAL, + m-NG-RAN-UE-XnAP-ID NG-RANnodeUEXnAPID OPTIONAL, + -- C-ifDCSetup: This IE shall be present in messages from E2 Node to NearRT-RIC if DC is established, + whereas from NearRT-RIC to E2 Node messages, this IE may not be included. To be reported by both MN and + SN. + globalGNB-ID GlobalGNB-ID OPTIONAL, + -- This IE shall not be used. This IE is replaced with globalNG-RANNode-ID. + ..., + globalNG-RANNode-ID GlobalNGRANNodeID OPTIONAL, + -- C-ifDCSetup: This IE shall be present in messages from E2 Node to NearRT-RIC if DC is established, + whereas from NearRT-RIC to E2 Node messages, this IE may not be included. To be reported only by SN. + cell-RNTI Cell-RNTI OPTIONAL +} + +UEID-GNB-CU-CP-E1AP-ID-List ::= SEQUENCE (SIZE(1..maxE1APid)) OF UEID-GNB-CU-CP-E1AP-ID-Item + +UEID-GNB-CU-CP-E1AP-ID-Item ::= SEQUENCE{ + gNB-CU-CP-UE-E1AP-ID GNB-CU-CP-UE-E1AP-ID, + ... +} + +UEID-GNB-CU-F1AP-ID-List ::= SEQUENCE (SIZE(1..maxF1APid)) OF UEID-GNB-CU-CP-F1AP-ID-Item + +UEID-GNB-CU-CP-F1AP-ID-Item ::= SEQUENCE{ + gNB-CU-UE-F1AP-ID GNB-CU-UE-F1AP-ID, + ... +} + +UEID-GNB-DU ::= SEQUENCE{ + gNB-CU-UE-F1AP-ID GNB-CU-UE-F1AP-ID, + ran-UEID RANUEID OPTIONAL, + ..., + cell-RNTI Cell-RNTI OPTIONAL +} + +UEID-GNB-CU-UP ::= SEQUENCE{ + gNB-CU-CP-UE-E1AP-ID GNB-CU-CP-UE-E1AP-ID, + ran-UEID RANUEID OPTIONAL, + ... +} + +UEID-NG-ENB ::= SEQUENCE{ + amf-UE-NGAP-ID AMF-UE-NGAP-ID, + guami GUAMI, + ng-eNB-CU-UE-W1AP-ID NGENB-CU-UE-W1AP-ID OPTIONAL, + -- C-ifCUDUSeparated: This IE shall be present in messages from E2 Node to NearRT-RIC for a CU-DU + separated ng-eNB, whereas from NearRT-RIC to E2 Node messages, this IE may not be included. + m-NG-RAN-UE-XnAP-ID NG-RANnodeUEXnAPID OPTIONAL, + -- C-ifDCSetup: This IE shall be present in messages from E2 Node to NearRT-RIC if DC is established, + whereas from NearRT-RIC to E2 Node messages, this IE may not be included. To be reported by both MN and + SN. + globalNgENB-ID GlobalNgENB-ID OPTIONAL, + -- This IE shall not be used. This IE is replaced with globalNG-RANNode-ID. + ..., + globalNG-RANNode-ID GlobalNGRANNodeID OPTIONAL, + -- C-ifDCSetup: This IE shall be present in messages from E2 Node to NearRT-RIC if DC is established, + whereas from NearRT-RIC to E2 Node messages, this IE may not be included. To be reported only by SN. + cell-RNTI Cell-RNTI OPTIONAL +} + +UEID-NG-ENB-DU ::= SEQUENCE{ + ng-eNB-CU-UE-W1AP-ID NGENB-CU-UE-W1AP-ID, + ..., + cell-RNTI Cell-RNTI OPTIONAL +} + +``` + +``` + +} + +UEID-EN-GNB ::= SEQUENCE{ + m-eNB-UE-X2AP-ID ENB-UE-X2AP-ID, + m-eNB-UE-X2AP-ID-Extension ENB-UE-X2AP-ID-Extension OPTIONAL, + globalENB-ID GlobalENB-ID, + gNB-CU-UE-F1AP-ID GNB-CU-UE-F1AP-ID OPTIONAL, +-- C-ifCUDUSeparated: This IE shall be present in messages from E2 Node to NearRT-RIC for a CU-DU +separated-enGNB, whereas from NearRT-RIC to E2 Node messages, this IE may not be included. + gNB-CU-CP-UE-E1AP-ID-List UEID-GNB-CU-CP-E1AP-ID-List OPTIONAL, +-- C-ifCPUPSeparated: This IE shall be present in messages from E2 Node to NearRT-RIC for a CP-UP +separated-enGNB, whereas from NearRT-RIC to E2 Node messages, this IE may not be included. + ran-UEID RANUEID OPTIONAL, + ..., + cell-RNTI Cell-RNTI OPTIONAL +} + +UEID-ENB ::= SEQUENCE{ + mME-UE-S1AP-ID MME-UE-S1AP-ID, + gUMMEI GUMMEI, + m-eNB-UE-X2AP-ID ENB-UE-X2AP-ID OPTIONAL, +-- This IE shall be present in messages from E2 Node to NearRT-RIC if DC is established, whereas from +NearRT-RIC to E2 Node messages, this IE may not be included. To be reported by MeNB and SeNB. + m-eNB-UE-X2AP-ID-Extension ENB-UE-X2AP-ID-Extension OPTIONAL, + globalENB-ID GlobalENB-ID OPTIONAL, +-- This IE shall be present in messages from E2 Node to NearRT-RIC if DC is established, whereas from +NearRT-RIC to E2 Node messages, this IE may not be included. To be reported only by SeNB. + ..., + cell-RNTI Cell-RNTI OPTIONAL +} + +-- + +-- 3GPP derived IEs + +-- + +-- NOTE: +-- - Extension fields removed and replaced with "..." +-- - IE names modified across all extracts to use "PLMNIdentity" + +-- + +-- IEs derived from 3GPP 36.413 (S1AP) +-- +-- + +ENB-ID ::= CHOICE { + macro-eNB-ID BIT STRING (SIZE (20)), + home-eNB-ID BIT STRING (SIZE (28)), + ..., + short-Macro-eNB-ID BIT STRING (SIZE(18)), + long-Macro-eNB-ID BIT STRING (SIZE(21)) +} + +GlobalENB-ID ::= SEQUENCE { + pLMNIdentity PLMNIdentity, + eNB-ID ENB-ID, + ... +} + +GUMMEI ::= SEQUENCE { + pLMN-Identity PLMNIdentity, + mME-Group-ID MME-Group-ID, + mME-Code MME-Code, + ... +} + +MME-Group-ID ::= OCTET STRING (SIZE (2)) + +MME-Code ::= OCTET STRING (SIZE (1)) + +MME-UE-S1AP-ID ::= INTEGER (0..4294967295) + +QCI ::= INTEGER (0..255) + +``` + +SubscriberProfileIDforRFP ::= INTEGER (1..256) + +``` +-- ***** +-- IEs derived from 3GPP 36.423 (X2AP) +-- ***** +-- Extension fields removed. +-- Note: to avoid duplicate names with NGAP, XnAP, etc.: +-- GNB-ID renamed ENGNB-ID, +-- GlobalGNB-ID renamed GlobalenGNB-ID, +-- UE-X2AP-ID renamed ENB-UE-X2AP-ID +-- UE-X2AP-ID-Extension renamed ENB-UE-X2AP-ID-Extension +-- ***** +``` + +``` +EN-GNB-ID ::= CHOICE { + en-gNB-ID BIT STRING (SIZE (22..32)), + ... +} +``` + +ENB-UE-X2AP-ID ::= INTEGER (0..4095) + +ENB-UE-X2AP-ID-Extension ::= INTEGER (0..4095, ...) + +E-UTRA-ARFCN ::= INTEGER (0..maxEARFCN) + +E-UTRA-PCI ::= INTEGER (0..503, ...) + +E-UTRA-TAC ::= OCTET STRING (SIZE(2)) + +``` +GlobalenGNB-ID ::= SEQUENCE { + plMN-Identity PLMNIdentity, + en-gNB-ID EN-GNB-ID, + ... +} +``` + +``` +-- ***** +-- IEs derived from 3GPP 37.473 (WlAP) +-- ***** +``` + +NGENB-CU-UE-WlAP-ID ::= INTEGER (0..4294967295) + +NGENB-DU-ID ::= INTEGER (0..68719476735) + +``` +-- ***** +-- IEs derived from 3GPP 38.331 (NR RRC) +-- ***** +``` + +NR-SSB-Index ::= INTEGER (0..maxNrofSSBs-1) + +RNTI-Value ::= INTEGER (0..65535) + +``` +-- ***** +-- IEs derived from 3GPP 38.413 (NGAP) +-- Extension fields removed and replaced with ... +-- ***** +``` + +AMFPointer ::= BIT STRING (SIZE(6)) + +AMFRegionID ::= BIT STRING (SIZE(8)) + +AMFSetID ::= BIT STRING (SIZE(10)) + +AMF-UE-NGAP-ID ::= INTEGER (0..1099511627775) + +EUTRACellIdentity ::= BIT STRING (SIZE(28)) + +``` + +EUTRA-CGI ::= SEQUENCE { + pLMNIdentity PLMNIdentity, + eUTRACellIdentity EUTRACellIdentity, + ... +} + +FiveQI ::= INTEGER (0..255, ...) + +GlobalGNB-ID ::= SEQUENCE { + pLMNIdentity PLMNIdentity, + gNB-ID GNB-ID, + ... +} + +GlobalNgENB-ID ::= SEQUENCE { + pLMNIdentity PLMNIdentity, + ngENB-ID NgENB-ID, + ... +} + +GNB-ID ::= CHOICE { + gNB-ID BIT STRING (SIZE(22..32)), + ... +} + +GUAMI ::= SEQUENCE { + pLMNIdentity PLMNIdentity, + aMFRegionID AMFRegionID, + aMFSetID AMFSetID, + aMFPointer AMFPointer, + ... +} + +IndexToRFSP ::= INTEGER (1..256, ...) + +NgENB-ID ::= CHOICE { + macroNgENB-ID BIT STRING (SIZE(20)), + shortMacroNgENB-ID BIT STRING (SIZE(18)), + longMacroNgENB-ID BIT STRING (SIZE(21)), + ... +} + +NRCellIdentity ::= BIT STRING (SIZE(36)) + +NR-CGI ::= SEQUENCE { + pLMNIdentity PLMNIdentity, + nRCellIdentity NRCellIdentity, + ... +} + +PLMNIdentity ::= OCTET STRING (SIZE(3)) + +QosFlowIdentifier ::= INTEGER (0..63, ...) + +SD ::= OCTET STRING (SIZE(3)) + +S-NSSAI ::= SEQUENCE { + sST SST, + sD SD + ... +} +OPTIONAL, +} + +SST ::= OCTET STRING (SIZE(1)) + +-- ***** +-- IEs derived from 3GPP 38.423 (XnAP) +-- ***** + +NG-RANnodeUEXnAPID ::= INTEGER (0.. 4294967295) + +GlobalNGRANNodeID ::= CHOICE { + +``` + +``` + + gNB GlobalGNB-ID, + ng-eNB GlobalNgENB-ID, + ... +} + +-- +-- IEs derived from 3GPP 37.483 (E1AP) +-- + +GNB-CU-CP-UE-E1AP-ID ::= INTEGER (0..4294967295) + +GNB-CU-UP-ID ::= INTEGER (0..68719476735) + + +-- +-- IEs derived from 3GPP 38.473 (F1AP) +-- + +FiveGS-TAC ::= OCTET STRING (SIZE(3)) + +FreqBandNrItem ::= SEQUENCE { + freqBandIndicatorNr INTEGER (1..1024, ...), + ... +} + +GNB-CU-UE-F1AP-ID ::= INTEGER (0..4294967295) + +GNB-DU-ID ::= INTEGER (0..68719476735) + +NR-PCI ::= INTEGER (0..1007) + +NR-ARFCN ::= SEQUENCE { + nRARFCN INTEGER (0..maxNRARFCN), + ... +} +NRFrequencyBand-List ::= SEQUENCE (SIZE(1..maxnoofNrCellBands)) OF NRFrequencyBandItem + +NRFrequencyBandItem ::= SEQUENCE { + freqBandIndicatorNr INTEGER (1..1024,...), + supportedSULBandList SupportedSULBandList, + ... +} + +NRFrequencyInfo ::= SEQUENCE { + nrARFCN NR-ARFCN, + frequencyBand-List NRFrequencyBand-List, + frequencyShift7p5khz NRFrequencyShift7p5khz OPTIONAL, + ... +} + +NRFrequencyShift7p5khz ::= ENUMERATED {false, true, ...} + +RANUEID ::= OCTET STRING (SIZE (8)) + +SupportedSULBandList ::= SEQUENCE (SIZE(0..maxnoofNrCellBands)) OF SupportedSULFreqBandItem + +SupportedSULFreqBandItem ::= SEQUENCE { + freqBandIndicatorNr INTEGER (1..1024,...), + ... +} + +END + +``` + +-- ASN1STOP + +### 6.3.3 Message transfer syntax + +E2SM shall use the ASN.1 Basic Packed Encoding Rules (BASIC-PER) Aligned Variant as transfer syntax, as specified in ITU-T Rec. X.691 [21]. + +# Annex (informative): Change History + +| Date | Revision | Description | +|-------------------|--------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>2020.01.22</b> | <b>01.00</b> | <b>Initial version</b> | +| 2020.07.09 | 01.00.01 | Inclusion of agreed CR "E2SM Change to Annex A layout" | +| 2020.07.10 | 01.00.02 | Clarification in table 7.8-2 within the embedded example document<br>Reference corrected in table in 8.2.2.1 | +| <b>2020.07.15</b> | <b>01.01</b> | <b>Editorial and functional corrections</b> | +| 2021.05.28 | v02.00.01 | Inclusion of CR agreed at WG3#99 < NOK.AO-2021.05.05-WG3-CR-0001-E2SM+common+IEs-v01 >. Endorsed as WG3#100 | +| 2021.07.07 | v02.00.02 | Adopted INT.AO-CR-0010. | +| <b>2021.08.10</b> | <b>02.00</b> | <b>New feature: Common IEs with shared ASN.1</b> | +| 2021.11.09 | V02.01.01 | Inclusion of CR agreed at WG3#117 <RSYS-2021.10.05-WG3-CR-0001-E2SM-Common-Correction for UEID and NRARFCN_v0.5><br>Alignment of copyright notice | +| 2021.11.22 | V02.01.02 | Corrections based on WG3 review comments during WG3 approval process | +| <b>2022.02.07</b> | <b>02.01</b> | <b>Additional common IEs including O-RAN agreed UEID. Editorial and functional corrections</b> | +| 2022.10.27 | V02.01.01 | Addition of CR:<br>< NOK-2022.09.01-WG3-CR-0003-E2SM-E1AP reference correction-v03> error in CR corrected (ref [9] should be 37.483)<br>< NOK-2022.10.31-WG3-CR-0004-E2SM-E2SM-CCC table entry-v01 ><br>Aligned for specification to latest O-RAN template | +| 2022.11.10 | V02.01.02 | Addition of CR:<br><QCM.AO-2022.10.27-WG3-CR-0001-E2SM-RIC Query-v03> | +| 2022.11.16 | V02.01.03 | Changes reflecting remarks received during WG3 approval process<br>- Alignment to latest O-RAN template<br>- Added R003 to file name<br>- Updated copyright year<br>- Corrected error in CRs implemented in previous drafts | +| <b>2022.12.07</b> | <b>03.00</b> | <b>New features: RIC Query. Editorial and functional corrections</b> | +| 2023.02.16 | V03.00.01 | CR <NOK-2023.02.08-WG3-CR-0006-E2SM-PAS step1-v02> approved Prague F2F 16/2/2023 | +| 2023.03.24 | V03.00.02 | Inclusion of corrections agreed during WG3 approval process as per <O-RAN.WG3.E2SM-R003-v03.00.01-ApprovalChanges-v2> | +| <b>2023.03.24</b> | <b>03.01</b> | <b>Alignment of O-RAN Drafting Rules (ODR) in preparation for ETSI PAS submission</b> | +| 2023.05.15 | V03.01.01 | CR <NOK-2023.01.23-WG3-CR-0005-E2SM-Beam-ID-v02> approved WG3#180<br>CR <NOK-2023.04.28-WG3-CR-0007-E2SM-Correction to clause 2.1-v01> approved WG3#183 | +| 2023.06.27 | V03.01.02 | CR <QCM-2023.04.17-WG3-CR-0002-E2SM-Addition of C-RNTI-v01> approved F2F Osaka<br>Editorial correction to ASN.1 variable name "nR-Beam-ID" (was "nR-Beam_ID") | +| 2023.07.26 | V03.01.03 | Editorial corrections based on comments received during WG3 poll. | +| 2023.07.27 | V03.01.04 | Editorial changes to align to O-RAN TS template v01.01 | +| <b>2023.07.31</b> | <b>04.00</b> | <b>Additional common IEs. Editorial and functional corrections</b> | + +| Date | Revision | Description | +|-------------------|--------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.10.30 | 04.00.01 | CR < QCM-2023.10.19-WG3-CR-0003-E2SM-UEID Structure for RIC Query_v0> approved WG3#202, 25/10/2023. Editorial correction to IE name in ASN.1 | +| 2023.11.15 | 04.00.02 | Editorial corrections implementing WG3 voting period feedback | +| 2023.11.21 | 04.00.03 | Restored full revision history into Annex: Change History and deletion of Annex: History | +| <b>2023.11.21</b> | <b>05.00</b> | <b>Additional common IEs. Editorial and function corrections.</b> | +| 2024.02.29 | 05.00.01 | CR <NOK-2024.02.13-WG3-CR-0008-E2SM-Change history-v01> approved F2F Athens | +| 2024.05.22 | 05.00.02 | CR <NOK-2024.04.22-WG3-CR-0009-E2SM-Editorial corrections for PAS-step2-v04> approved WG3#225<br>Also includes editorial changes to align with ETSI “Edit Help” changes during PAS processing of v04.00 | +| 2024.07.26 | 05.00.03 | Editorial corrections implementing review comments collected during July24 train approval | +| <b>2024.07.26</b> | <b>06.00</b> | <b>Alignment to ETSI Drafting Rules and implementation of all agreed ETSI PAS comments</b> | +| 2024.10.09 | 06.00.01 | CR <NOK-2024.09.27-E2SM-CR-0011-EditHelp alignment-v1> approved WG3#241 | +| 2024.11.24 | 06.00.02 | Editorial changes to align with O-RAN WORKPROC v04.00<br>CR <NOK-2024.09.02-E2SM-CR-0010-Adding E2SM-LLC to table 5-2-v02> approved WG3#239<br>CR <NOK-2024.10.23-WG3-CR-0013-E2SM-Handling LS from MSG-v02> approved F2F Montreal<br>CR <NOK-2024.11.12-E2SM-CR-0014-Adding Error handling Cause IE- v02> approved WG3#245<br>CR <NOK-2024.11.13-WG3-CR-E2SM-0015-Adding RIC Assistance IE-v01 > approved WG3#245<br>Editorial changes to align with E2SM-v06.00.02 review comments | +| <b>2024.12.04</b> | <b>07.00</b> | <b>New features: RIC Assistance, Service Level error handling. Implementation of changes related to ETSI MSG Liaison</b> | +| | | | \ No newline at end of file diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..19f401a5cfbf08aa0ec7781203e69177a2b7e39d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5836b6268e1b6d229168b5e47faaaafd32832660ba85975f8ee7a6e10fc63fff +size 4560 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/1564eeaa50005a8c52d5d9471f7c12e4_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/1564eeaa50005a8c52d5d9471f7c12e4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..463eb1225db5c7d6cf1ec77c8b47133d7b0ee13a --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/1564eeaa50005a8c52d5d9471f7c12e4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:01d8bb67b202042090b8001856c68f6e5f0c3714a5eb15da2750eaacef43f1b3 +size 4587 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/17398cfc35dde22fa5a80caabe669739_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/17398cfc35dde22fa5a80caabe669739_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ae115f85c71c7c4dd5ac246f8d02e9dc29c8af6 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/17398cfc35dde22fa5a80caabe669739_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c5775240b9ed1a2100a9c61aca08d03763ec191986acc2c52895232c0e85e48b +size 4429 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/435b6060161bc935b11eaf1554bc356b_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/435b6060161bc935b11eaf1554bc356b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..73c24cb3de2d07b74d05e16898fa0eed6e0d0391 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/435b6060161bc935b11eaf1554bc356b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ed11dec87b18d8bdcc93132f978707e8da3cf6fd5893e6d6d0d2d68d920d886 +size 4528 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/497c638391dae365ad12f1ebd687c445_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/497c638391dae365ad12f1ebd687c445_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..008ff69f0900d366186f2f68e6ee8cbfc18c468e --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/497c638391dae365ad12f1ebd687c445_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09238b459f3ad3429d2ba3917bc267325e8584c48d205b49916cca0dba7fbd7c +size 4549 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/551e35d264492786d0d610557ccc1b55_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/551e35d264492786d0d610557ccc1b55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eca96f14eff173ab5ead5b4ef80ff5827e92c33d --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/551e35d264492786d0d610557ccc1b55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8bb0af2dd788e055159db7a05c0b9285e7d655c861421ac8dc37e4b94c3b343 +size 4454 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/676c91b64382565d972aaef1aeb60f35_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/676c91b64382565d972aaef1aeb60f35_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..17e9aeebaaf53d6100482d20b8dbdbd363ecb52b --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/676c91b64382565d972aaef1aeb60f35_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b0f20f21b66dfe1b951c86e5ef199d9677e37716f224c6a93c40e9a0a2979aa5 +size 4549 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/8c827310f7c2633b38ac4d60fbe19777_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/8c827310f7c2633b38ac4d60fbe19777_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5f7be5be6d90eb413d30fcf3419b2044a512d565 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/8c827310f7c2633b38ac4d60fbe19777_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:041f2ce46156e147aef76cabd2c9112e1a073449f8c87080484bff9822cdc5ed +size 4545 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..08a9c509da7e591b85ce9c11c7659f729776badc --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e51e29a8c647908fe9f48f56b660f7378772dafa9202a271bcb2032f560fafe1 +size 4531 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/a55ba4c7522c2f205dc75aceded51060_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/a55ba4c7522c2f205dc75aceded51060_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db0f2f3203dac69e38c4f1a33d5942e96fd6d727 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/a55ba4c7522c2f205dc75aceded51060_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2a0f19e72f1de46ac81a4c116bcdbb05a477efc75f6fcc1fc1c15f0f7f4290b3 +size 242145 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d73ac8b8be38faf362b1eaa59fff1f3f167364fb --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3276e59412020445a9dbac9cf2ede064a279427afdcaa0dcf94fa0620d916726 +size 4546 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2607b0eef27677fb38e9fdbba214fde5d86a7f72 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9e383e92647a2356488a833110e26ad296a5dd136dd01f365e78a67474a8258 +size 4548 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/e5e9cc82d567781d4fd1b713b983e827_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/e5e9cc82d567781d4fd1b713b983e827_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..99c7f40f5621c7d07b7dc590f597ae97409b0376 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/e5e9cc82d567781d4fd1b713b983e827_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b86f4b847c1a5a2d4a7736c9e20aca8836843dc9155d091d79f66cf3253cf91 +size 137248 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/raw.md b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..cbb199b50b2e65663492f44727e7169131b79c4c --- /dev/null +++ b/marked/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00/raw.md @@ -0,0 +1,10998 @@ + + +# --- **O-RAN Work Group 3 (WG-3) Near-Real-time RAN Intelligent Controller E2 Service Model (E2SM), RAN Control** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +"© 2019. 3GPP™ TSs and TRs are the property of ARIB, ATIS, CCSA, ETSI, TSDSI, TTA and TTC who jointly own the copyright in them. They are subject to further modifications and are therefore provided to you "as is" for information purposes only. Further use is strictly prohibited." + +"© 2020. 3GPP™ TSs and TRs are the property of ARIB, ATIS, CCSA, ETSI, TSDSI, TTA and TTC who jointly own the copyright in them. They are subject to further modifications and are therefore provided to you "as is" for information purposes only. Further use is strictly prohibited." + +# Contents + +| | | +|---------------------------------------------------------------------------------|----| +| Foreword..... | 7 | +| Modal verbs terminology ..... | 7 | +| 1 Scope..... | 8 | +| 2 References ..... | 9 | +| 2.1 Normative references ..... | 9 | +| 2.2 Informative references ..... | 10 | +| 3 Definitions and Abbreviations ..... | 10 | +| 3.1 Terms ..... | 10 | +| 3.2 Abbreviations..... | 10 | +| 4 General ..... | 12 | +| 4.1 Procedure Specification Principles ..... | 12 | +| 4.2 Forwards and Backwards Compatibility ..... | 12 | +| 4.3 Specification Notations..... | 12 | +| 4.4 Void ..... | 13 | +| 5 E2SM Services ..... | 14 | +| 6 RAN Function Service Model Description ..... | 15 | +| 6.1 RAN Function Overview ..... | 15 | +| 6.2 RAN Function exposure services..... | 15 | +| 6.2.1 REPORT service ..... | 15 | +| 6.2.2 INSERT service ..... | 15 | +| 6.2.3 CONTROL service..... | 16 | +| 6.2.4 POLICY service ..... | 16 | +| 6.2.5 QUERY service..... | 17 | +| 6.3 REPORT service description ..... | 17 | +| 6.4 INSERT service description ..... | 17 | +| 6.5 CONTROL service description..... | 18 | +| 6.6 POLICY service description ..... | 18 | +| 6.6.1 Overview ..... | 18 | +| 6.6.2 Policy approach "Control" ..... | 18 | +| 6.6.3 Policy Approach "Offset" ..... | 19 | +| 6.7 QUERY service description..... | 19 | +| 7 RAN Function Description..... | 20 | +| 7.1 RAN Function Definition ..... | 20 | +| 7.2 RAN Function name ..... | 20 | +| 7.3 RIC Event Trigger Definition IE styles ..... | 21 | +| 7.3.1 RIC Event Trigger Definition IE style list ..... | 21 | +| 7.3.2 RIC Event Trigger Definition IE style 1: Message Event ..... | 21 | +| 7.3.3 RIC Event Trigger Definition IE style 2: Call Process Breakpoint..... | 21 | +| 7.3.4 RIC Event Trigger Definition IE style 3: E2 Node Information Change ..... | 23 | +| 7.3.5 RIC Event Trigger Definition IE style 4: UE Information Change ..... | 23 | +| 7.4 Supported RIC REPORT Services..... | 24 | +| 7.4.1 REPORT Service style list ..... | 24 | +| 7.4.2 REPORT Service Style 1: Message Copy ..... | 24 | +| 7.4.3 REPORT Service Style 2: Call Process Outcome ..... | 25 | +| 7.4.4 REPORT Service Style 3: E2 Node Information ..... | 25 | +| 7.4.5 REPORT Service Style 4: UE Information ..... | 26 | +| 7.5 Supported RIC INSERT Services ..... | 27 | +| 7.5.1 INSERT Service style list ..... | 27 | +| 7.5.2 INSERT Service Style 1: Radio Bearer Control Request..... | 27 | +| 7.5.3 INSERT Service Style 2: Radio Resource Allocation Control Request..... | 29 | +| 7.5.4 INSERT Service Style 3: Connected Mode Mobility Control Request..... | 30 | + +| | | | +|--------|----------------------------------------------------------------------------|-----| +| 7.5.5 | INSERT Service Style 4: Radio Access Control Request ..... | 31 | +| 7.5.6 | INSERT Service Style 5: Dual Connectivity Control Request ..... | 32 | +| 7.5.7 | INSERT Service Style 6: Carrier Aggregation Control Request ..... | 33 | +| 7.5.8 | INSERT Service Style 7: Idle Mode Mobility Control Request ..... | 34 | +| 7.5.9 | INSERT Service Style 255: Multiple Actions Control Request ..... | 35 | +| 7.6 | Supported RIC CONTROL Services ..... | 36 | +| 7.6.1 | CONTROL Service Style Types ..... | 36 | +| 7.6.2 | CONTROL Service Style 1: Radio Bearer Control ..... | 37 | +| 7.6.3 | CONTROL Service Style 2: Radio Resource Allocation Control ..... | 39 | +| 7.6.4 | CONTROL Service Style 3: Connected Mode Mobility Control ..... | 41 | +| 7.6.5 | CONTROL Service Style 4: Radio Access Control ..... | 42 | +| 7.6.6 | CONTROL Service Style 5: Dual Connectivity Control ..... | 44 | +| 7.6.7 | CONTROL Service Style 6: Carrier Aggregation Control ..... | 45 | +| 7.6.8 | CONTROL Service Style 7: Idle Mode Mobility Control ..... | 47 | +| 7.6.9 | CONTROL Service Style 8: UE information and assignment ..... | 48 | +| 7.6.10 | CONTROL Service Style 255: Multiple Actions Control ..... | 49 | +| 7.6.11 | CONTROL Service Style 9: Measurement Reporting Configuration Control ..... | 50 | +| 7.6.12 | CONTROL Service Style 10: Beamforming Configuration Control ..... | 52 | +| 7.7 | Supported RIC POLICY Services ..... | 53 | +| 7.7.1 | POLICY Service style list ..... | 53 | +| 7.7.2 | POLICY Service Style 1: Radio Bearer Policy ..... | 54 | +| 7.7.3 | POLICY Service Style 2: Radio Resource Allocation Policy ..... | 55 | +| 7.7.4 | POLICY Service Style 3: Connected Mode Mobility Policy ..... | 56 | +| 7.7.5 | POLICY Service Style 4: Radio Access Policy ..... | 57 | +| 7.7.6 | POLICY Service Style 5: Dual Connectivity (DC) Policy ..... | 57 | +| 7.7.7 | POLICY Service Style 6: Carrier Aggregation (CA) Policy ..... | 58 | +| 7.7.8 | POLICY Service Style 7: Idle Mode Mobility Policy ..... | 59 | +| 7.7.9 | POLICY Service Style 8: Measurement Reporting Configuration Policy ..... | 59 | +| 7.7.10 | POLICY Service Style 9: Beamforming Configuration Policy ..... | 60 | +| 7.8 | Supported RIC QUERY Services ..... | 61 | +| 7.8.1 | QUERY Service style list ..... | 61 | +| 7.8.2 | QUERY Service Style 1: E2 Node Information Query ..... | 61 | +| 7.8.3 | QUERY Service Style 2: UE Information Query ..... | 61 | +| 7.9 | Supported RIC Service Styles and E2SM IE Formats ..... | 62 | +| 8 | RAN Parameter assignments ..... | 64 | +| 8.0 | Approach ..... | 64 | +| 8.1 | RAN parameters for Event Trigger ..... | 64 | +| 8.1.1 | Common RAN Parameters ..... | 64 | +| 8.1.2 | RAN Parameters for Call Process Breakpoint ..... | 115 | +| 8.1.3 | RAN Parameters for UE Identification ..... | 167 | +| 8.1.4 | RAN Parameters for Cell Identification ..... | 169 | +| 8.1.5 | UE Events ..... | 169 | +| 8.2 | RAN parameters for REPORT services ..... | 169 | +| 8.2.1 | RAN Parameters for Report Service Style 1 ..... | 169 | +| 8.2.2 | RAN Parameters for Report Service Style 2 ..... | 171 | +| 8.2.3 | RAN Parameters for Report Service Style 3 ..... | 171 | +| 8.2.4 | RAN Parameters for Report Service Style 4 ..... | 172 | +| 8.3 | RAN parameters for INSERT services ..... | 174 | +| 8.3.1 | Approach ..... | 174 | +| 8.3.2 | Radio Bearer Control request ..... | 174 | +| 8.3.3 | Radio Resource Allocation Control request ..... | 174 | +| 8.3.4 | Connected Mode Mobility Control Request ..... | 175 | +| 8.3.5 | Radio Access Control request ..... | 175 | +| 8.3.6 | Dual Connectivity Control request ..... | 175 | +| 8.3.7 | Carrier Aggregation Control request ..... | 176 | +| 8.3.8 | Idle Mode Mobility Control request ..... | 176 | +| 8.3.9 | Common RAN Parameters for INSERT Service styles ..... | 176 | +| 8.3.10 | Indication Semantics Description for interpretation by the RIC ..... | 176 | +| 8.4 | RAN Parameters for Control Actions ..... | 177 | +| 8.4.1 | Approach ..... | 177 | + +| | | | +|--------|-----------------------------------------------------|-----| +| 8.4.2 | Radio Bearer Control ..... | 178 | +| 8.4.3 | Radio Resource Allocation Control ..... | 187 | +| 8.4.4 | Connected Mode Mobility Control ..... | 196 | +| 8.4.5 | Radio Access Control ..... | 203 | +| 8.4.6 | Dual Connectivity Control ..... | 212 | +| 8.4.7 | Carrier Aggregation Control ..... | 223 | +| 8.4.8 | Idle Mode Mobility Control ..... | 225 | +| 8.4.9 | UE identification, information and assignment ..... | 226 | +| 8.4.10 | Measurement Reporting Configuration Control ..... | 228 | +| 8.4.11 | Beamforming Configuration Control ..... | 271 | +| 8.5 | RAN parameters for POLICY services ..... | 275 | +| 8.5.1 | Approach ..... | 275 | +| 8.5.1A | Common RAN Parameters for POLICY services ..... | 276 | +| 8.5.2 | Radio Bearer Policy ..... | 277 | +| 8.5.3 | Radio Resource Allocation Policy ..... | 279 | +| 8.5.4 | Connected Mode Mobility Policy ..... | 281 | +| 8.5.5 | Radio Access Policy ..... | 286 | +| 8.5.6 | Dual Connectivity Policy ..... | 288 | +| 8.5.7 | Carrier Aggregation Policy ..... | 291 | +| 8.5.8 | Idle Mode Mobility Policy ..... | 293 | +| 8.5.9 | Measurement Reporting Configuration Policy ..... | 294 | +| 8.5.10 | Beamforming Configuration Policy ..... | 296 | +| 8.6 | RAN parameters for QUERY services ..... | 301 | +| 8.6.1 | RAN Parameters for Query Service Style 1 ..... | 301 | +| 8.6.2 | RAN Parameters for Query Service Style 2 ..... | 303 | +| 9 | Elements for E2SM Service Model ..... | 303 | +| 9.1 | General ..... | 303 | +| 9.2 | Message Functional Definition and Content ..... | 303 | +| 9.2.1 | Messages for RIC Functional procedures ..... | 303 | +| 9.2.2 | Messages for RIC Global Procedures ..... | 326 | +| 9.3 | Information Element definitions ..... | 335 | +| 9.3.1 | General ..... | 335 | +| 9.3.2 | RAN Function Name ..... | 335 | +| 9.3.3 | RIC Style Type ..... | 335 | +| 9.3.4 | RIC Style Name ..... | 335 | +| 9.3.5 | RIC Format Type ..... | 335 | +| 9.3.6 | Control Action ID ..... | 335 | +| 9.3.7 | Control Action Name ..... | 335 | +| 9.3.8 | RAN Parameter ID ..... | 335 | +| 9.3.9 | RAN Parameter Name ..... | 336 | +| 9.3.10 | UE ID ..... | 336 | +| 9.3.11 | RAN Parameter Value Type ..... | 337 | +| 9.3.12 | RAN Parameter Structure ..... | 337 | +| 9.3.13 | RAN Parameter List ..... | 338 | +| 9.3.14 | RAN Parameter Value ..... | 338 | +| 9.3.15 | Call Process Type ID ..... | 338 | +| 9.3.16 | Insert Indication ID ..... | 338 | +| 9.3.17 | Insert Indication Name ..... | 338 | +| 9.3.18 | RAN Call Process ID ..... | 339 | +| 9.3.19 | Call Process Type Name ..... | 339 | +| 9.3.20 | Policy Action ..... | 339 | +| 9.3.21 | Event Trigger Condition ID ..... | 339 | +| 9.3.22 | Event Trigger ID for UE ..... | 339 | +| 9.3.23 | Event Trigger ID for UE Event ..... | 340 | +| 9.3.24 | Event Trigger ID for Cell ..... | 340 | +| 9.3.25 | Logical OR ..... | 340 | +| 9.3.26 | Event Trigger UE Information ..... | 340 | +| 9.3.27 | Event Trigger Cell Information ..... | 341 | +| 9.3.28 | Event Trigger UE Event Information ..... | 341 | +| 9.3.29 | RAN Parameter Conditional Criteria Definition ..... | 342 | + +| | | | +|-------------------------------|-------------------------------------------------------------------|-----| +| 9.3.30 | RAN Parameter Test ..... | 342 | +| 9.3.31 | RAN Parameter Test Condition ..... | 342 | +| 9.3.32 | Network Interface Type ..... | 343 | +| 9.3.33 | Network Interface Identifier ..... | 343 | +| 9.3.34 | Network Interface Message ID ..... | 343 | +| 9.3.35 | RRC Message ID ..... | 343 | +| 9.3.36 | Cell Global ID ..... | 343 | +| 9.3.37 | RRC State ..... | 344 | +| 9.3.38 | Neighbour Relation Information ..... | 345 | +| 9.3.39 | Serving Cell PCI ..... | 346 | +| 9.3.40 | Serving Cell ARFCN ..... | 346 | +| 9.3.41 | NR CGI ..... | 346 | +| 9.3.42 | NR PCI ..... | 346 | +| 9.3.43 | NR TAC ..... | 346 | +| 9.3.44 | NR Frequency Info ..... | 346 | +| 9.3.45 | E-UTRA CGI ..... | 346 | +| 9.3.46 | E-UTRA PCI ..... | 346 | +| 9.3.47 | E-UTRA TAC ..... | 346 | +| 9.3.48 | E-UTRA ARFCN ..... | 346 | +| 9.3.49 | Call Process Breakpoint ID ..... | 346 | +| 9.3.50 | Call Process Breakpoint Name ..... | 347 | +| 9.3.51 | RAN Parameter Definition ..... | 347 | +| 9.3.52 | Associated UE Information ..... | 347 | +| 9.3.53 | UE Filter ID ..... | 348 | +| 9.3.54 | UE Group ID ..... | 348 | +| 9.3.55 | Entity Filter ID ..... | 348 | +| 9.3.56 | UE Group Definition ..... | 349 | +| 9.3.57 | Partial UE ID ..... | 349 | +| 9.3.58 | Policy Condition ID ..... | 349 | +| 9.3.59 | PLMN Identity ..... | 349 | +| 9.3.60 | Serving Cell Configuration Common ..... | 349 | +| 9.4 | Information Element Abstract Syntax (with ASN.1) ..... | 350 | +| 9.4.1 | General ..... | 350 | +| 9.4.2 | Information Element Definitions ..... | 350 | +| 9.5 | Message transfer syntax ..... | 370 | +| 10 | Handling of Unknown, Unforeseen and Erroneous Protocol Data ..... | 370 | +| Annex A (Informative): ..... | | 371 | +| Examples on IE Contents ..... | | 371 | +| A.1 | Introduction ..... | 371 | +| A.2 | Connected mode mobility based on UE measurement report ..... | 371 | +| A.2.1 | Assumptions ..... | 371 | +| A.2.2 | Solution using RIC Services Insert and Control ..... | 371 | +| A.2.3 | Solution using RIC Service Policy ("Offset" based approach) ..... | 376 | +| Revision History ..... | | 381 | +| History ..... | | 385 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG3 of the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the E2 Service Model (E2SM) for the Near RT RIC RAN Control interaction. + +# 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE 1: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +NOTE 2: In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +The following referenced documents are necessary for the application of the present document. + +- [1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. +- [2] O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, Architecture & E2 General Aspects and Principles (E2GAP) +- [3] ORAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Application Protocol (E2AP). +- [4] O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Service Model (E2SM) +- [5] 3GPP TR 25.921: "Guidelines and principles for protocol description and error handling". +- [6] ITU-T Recommendation X.680 (2002-07): "Information technology – Abstract Syntax Notation One (ASN.1): Specification of basic notation". +- [7] ITU-T Recommendation X.681 (2002-07): "Information technology – Abstract Syntax Notation One (ASN.1): Information object specification". +- [8] ITU-T Recommendation X.691 (2002-07): "Information technology - ASN.1 encoding rules - Specification of Packed Encoding Rules (PER) " +- [9] Reserved +- [10] TS 38.410: “NG-RAN; NG general aspects and principles”. +- [11] TS 38.413: “NG-RAN; NG Application Protocol (NGAP)”. +- [12] Reserved +- [13] TS 36.413: “E-UTRAN; S1 Application Protocol (S1AP)”. +- [14] TS 38.420: “NG-RAN; Xn general aspects and principles”. +- [15] TS 38.423: “NG-RAN; Xn Application Protocol (XnAP)”. +- [16] TS 36.420: “E-UTRAN; X2 general aspects and principles”. +- [17] TS 36.423: “E-UTRAN; X2 Application Protocol (X2AP)”. +- [18] TS 38.470: “NG-RAN; F1 general aspects and principles”. +- [19] TS 38.473: “NG-RAN; F1 Application Protocol (F1AP)”. +- [20] TS 38.460: “NG-RAN; E1 general aspects and principles”. +- [21] TS 37.483: “NG-RAN; E1 Application Protocol (E1AP)”. +- [22] TS 38.331: “NR; Radio Resource Control (RRC) Protocol Specification”. +- [23] TS 36.331: “E-UTRA; Radio Resource Control (RRC) Protocol Specification”. +- [24] TS 38.323: “NR; Packet Data Convergence Protocol (PDCP) specification”. +- [25] TS 38.322: “NR; Radio Link Control (RLC) protocol specification”. +- [26] TS 38.321: “NR; Medium Access Control (MAC) protocol specification”. + +- [27] TS 25.321: “Medium Access Control (MAC) protocol specification”. +- [28] TS 28.552: “Management and orchestration 5G performance measurements”. +- [29] Reserved +- [30] IETF RFC 5905 (2010-06): “Network Time Protocol Version 4: Protocol and Algorithms Specification” +- [31] TS 37.340: “E-UTRA and NR Multiconnectivity Stage 2”. +- [32] O-RAN Working Group 3, Use Case Requirements (UCR) +- [33] O-RAN Working Group 1, Massive MIMO Use Cases Technical Report +- [34] O-RAN.WG4.CUS.0-R003-v13, “O-RAN Working Group 4, Control, User and Synchronization Plane Specification” +- [35] TS 28.541: “5G; Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3”. +- [36] TS 28.214: “NR; Physical layer procedures for data”. +- [37] TS 38.912: “Study on New Radio (NR) access technology”. + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +# --- 3 Definitions and Abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in 3GPP TR 23.905 [1], O-RAN WG1.OAD [18], O-RAN WG3.E2GAP [2], O-RAN.WG3.E2SM [4] and the following apply: + +**SpCell:** as defined in TS 37.340 [31]. + +## 3.2 Abbreviations + +For the purposes of the present document, the following abbreviations apply. + +| | | +|-------------|-------------------------------------------| +| O-CU | O-RAN Central Unit | +| O-CU-CP | O-RAN Central Unit – Control Plane | +| O-CU-UP | O-RAN Central Unit – User Plane | +| O-DU | O-RAN Distributed Unit | +| Near-RT RIC | Near-real-time RAN Intelligent Controller | +| RC | RAN Control | + + + +# 4 General + +## 4.1 Procedure Specification Principles + +The principle for specifying the procedure logic is to specify the functional behavior of the terminating node exactly and completely. Any rule that specifies the behavior of the originating node shall be possible to be verified with information that is visible within the system. + +The following specification principles have been applied for the procedure text in clause 8: + +- The procedure text discriminates between: + +- 1) Functionality which "shall" be executed. + +The procedure text indicates that the receiving node "shall" perform a certain function Y under a certain condition. If the receiving node supports procedure X but cannot perform functionality Y requested in the REQUEST message of a Class 1 EP, the receiving node shall respond with the message used to report unsuccessful outcome for this procedure, containing an appropriate cause value. + +- 2) Functionality which "shall, if supported" be executed. + +The procedure text indicates that the receiving node "shall, if supported," perform a certain function Y under a certain condition. If the receiving node supports procedure X, but does not support functionality Y, the receiving node shall proceed with the execution of the EP, possibly informing the requesting node about the not supported functionality. + +- Any required inclusion of an optional IE in a response message is explicitly indicated in the procedure text. If the procedure text does not explicitly indicate that an optional IE shall be included in a response message, the optional IE shall not be included. For requirements on including *Criticality Diagnostics* IE, see clause 10. + +## 4.2 Forwards and Backwards Compatibility + +The forwards and backwards compatibility of the protocol is assured by a mechanism where all current and future messages, and IEs or groups of related IEs, include ID and criticality fields that are coded in a standard format that will not be changed in the future. These parts can always be decoded regardless of the standard version. + +## 4.3 Specification Notations + +For the purposes of the present document, the following notations apply: + +| | | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Service | when referring to a Service in the specification the <b>SERVICE NAME</b> is written with upper case characters and in bold followed by the word "service", e.g. <b>REPORT</b> service. | +| Procedure | When referring to an elementary procedure in the specification the Procedure Name is written with the first letters in each word in upper case characters followed by the word "procedure", e.g. Handover Preparation procedure. | +| Message | When referring to a message in the specification the MESSAGE NAME is written with all letters in upper case characters followed by the word "message", e.g. HANDOVER REQUEST message. | +| IE | When referring to an information element (IE) in the specification the <i>Information Element Name</i> is written with the first letters in each word in upper case characters and all letters in Italic font followed by the abbreviation "IE", e.g. <i>E-RAB ID</i> IE. | +| Value of an IE | When referring to the value of an information element (IE) in the specification the "Value" is written as it is specified in the specification enclosed by quotation marks, e.g. "Value". | + +## 4.4 Void + +# 5 E2SM Services + +As defined in E2 General Aspects and Principles O-RAN WG3.E2GAP [1], a given RAN Function offers a set of services to be exposed over the E2 (**REPORT**, **INSERT**, **CONTROL** and/or **POLICY**) using O-RAN WG3.E2AP [3] defined procedures. Each of the E2AP Procedures listed in table 5-1 contains specific E2 Node RAN Function dependent Information Elements (IEs). + +**Table 5-1: Relationship RAN Function specific E2AP Information elements and E2AP Procedures** + +| RAN Function specific E2AP Information Elements | E2AP Information Element reference | Related E2AP Procedures | +|-------------------------------------------------|------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| <i>RIC Event Trigger Definition IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.9 | RIC Subscription | +| <i>RIC Action Definition IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.12 | RIC Subscription | +| <i>RIC Indication Header IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.17 | RIC Indication | +| <i>RIC Indication Message IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.16 | RIC Indication | +| <i>RIC Call Process ID IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.18 | RIC Indication<br>RIC Control | +| <i>RIC Control Header IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.20 | RIC Control | +| <i>RIC Control Message IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.19 | RIC Control | +| <i>RIC Control Outcome IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.25 | RIC Control | +| <i>RAN Function Definition IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.23 | E2 Setup<br>RIC Service Update | +| <i>RIC Query Header IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.36 | RIC Query | +| <i>RIC Query Definition IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.37 | RIC Query | +| <i>RIC Query Outcome IE</i> | O-RAN WG3.E2AP [3] Clause 9.2.38 | RIC Query | +| <i>Service Layer Cause IE</i> | O-RAN WG3.E2AP [3] clause 9.2.1 | RIC Subscription<br>RIC Subscription modification<br>RIC Indication<br>RIC Control<br>RIC Query<br>Error Indication<br>E2 Setup<br>RIC Service Update | + +All of these RAN Function specific E2AP IEs are defined in O-RAN WG3.E2AP [3] as “OCTET STRING”. + +The purpose of this specification is to define the contents of these fields for the specific RAN function “RAN Control (RC)”. + +# 6 RAN Function Service Model Description + +## 6.1 RAN Function Overview + +For the purposes of this E2 Service Model, E2SM-RC, the E2 Node terminating the E2 Interface is assumed to host one or more instances of the RAN Function “RAN Control” which performs the following functionalities: + +- E2 REPORT services used to expose RAN control and UE context related information +- E2 INSERT services used to suspend RAN control related call processes +- E2 CONTROL services used to resume or initiate RAN control related call processes, modify RAN configuration and/or E2 service-related UE context information +- E2 POLICY services used to modify the behaviour of RAN control related processes +- E2 QUERY services used to request and retrieve RAN and/or UE related information +- Service layer error reporting + +This E2SM specification provides a set of RAN Function exposure services described in clause 6.2 and has been prepared with the assumption that the same E2SM may be used to describe either a single RAN Function in the E2 Node handling all RAN control related call processes or more than one RAN Function in the E2 Node with each instance handling a subset of the RAN control related call processes on the E2 Node. + +## 6.2 RAN Function exposure services + +### 6.2.1 REPORT service + +The “RAN Control” RAN Function provides selective support of the following **REPORT** services: + +- Copy of Complete message (from Network Interface or RRC), used for monitoring POLICY services, data gathering (to populate the Near-RT RIC UE-NIB and/or ML services data pipeline), etc. +- Call process outcome with associated information on UE context and/or RAN status information, used for monitoring [CONTROL and] POLICY services, data gathering (to populate the Near-RT RIC UE-NIB and/or ML services data pipeline), etc. +- E2 Node Information and Cell related Information, used for monitoring of E2 Node and Cell configuration changes, triggering POLICY deletion, changing notifications (to reset Near-RT RIC optimization services), etc.. +- UE Information, used for monitoring of UE information changes, triggering E2 Control, location tracking, etc. + +NOTE: Only the UE with user consent can be configured to report location information. + +### 6.2.2 INSERT service + +The “RAN Control” RAN Function provides selective support of the following **INSERT** services: + +Fundamental level: + +- Radio Bearer Control request, used for requesting the RIC to control DRB QoS modification, QoS flow to DRB (re)mapping, Logical channel (re)configuration, Radio bearer admission control, Split bearer and PDCP duplication control, etc. +- Radio Resource Allocation Control request, used for requesting the RIC to control Discontinuous Reception (DRX), Scheduling request (SR), Semi-Persistent Scheduling (SPS), Configured Grant, Channel Quality Indicator (CQI) table, Slice level PRB quota, etc. +- Connected Mode Mobility Control request, used for requesting the RIC to control operations of Handover (HO), Conditional handover (CHO), Dual Active Protocol Stack (DAPS) HO, etc. +- Radio Access Control request, used for requesting the RIC to control parameters related to RACH back-off, RRC connection reject, RRC connection release, Access barring, UE admission, etc. + +- Dual Connectivity (DC) Control request, used for requesting the RIC to control operations of Dual Connectivity (DC) including Change of bearer termination point (MN or SN) and/or bearer types, etc. +- Carrier Aggregation (CA) Control request, used for requesting the RIC to control operations of Carrier Aggregation (CA) involving secondary cell re-selection. +- Idle Mode Mobility Control request, used for requesting the RIC to control intra-frequency, inter-frequency, inter-RAT cell reselection priority, idle timers, etc. + +Integrated level: + +- Multiple Actions Control request, used for requesting the RIC to command multiple actions of the selected fundamental level INSERT services. + +### 6.2.3 CONTROL service + +The “RAN Control” RAN Function provides selective support of the following **CONTROL** services: + +Fundamental level: + +- Radio Bearer Control, used for DRB QoS modification, QoS flow to DRB (re)mapping, Logical channel (re)configuration, Radio bearer admission control, Split bearer and PDCP duplication control, etc. +- Radio Resource Allocation Control, used to control Discontinuous Reception (DRX), Scheduling request (SR), Semi-Persistent Scheduling (SPS), Configured Grant, Channel Quality Indicator (CQI) table, Slice level PRB quota, etc. +- Connected Mode Mobility Control, used to control operations of Handover (HO), Conditional handover (CHO), Dual Active Protocol Stack (DAPS) HO, etc. +- Radio Access Control, used for modification of RACH back-off, RRC connection reject, RRC connection release, Access barring, UE admission, etc. +- Dual Connectivity (DC) Control, used to control operations of Dual Connectivity (DC) including Change of bearer termination point (MN or SN) and/or bearer types, etc. +- Carrier Aggregation (CA) Control, used to control operations of Carrier Aggregation (CA). +- Idle Mode Mobility Control, used for modification of intra-frequency, inter-frequency, inter-RAT cell reselection priority, idle timers, etc. +- UE identification, information and assignment: used to assign UE to RAN UE group, to obtain information on UE, and to complete UE identification based on partial information. +- Measurement Report (MR) Configuration Control, used to control configuration of RRC measurement objects, reporting objects, etc. +- Beamforming Configuration Control, used to control configuration of Non-GoB Beamforming Mode. + +Integrated level: + +- Multiple Actions Control, used to command multiple actions of the selected fundamental level CONTROL services in one message. + +### 6.2.4 POLICY service + +The “RAN Control” RAN Function provides selective support of the following **POLICY** services: + +- Radio Bearer Policy, used to modify the behaviour of call processes related to DRB QoS control, QoS flow to DRB mapping, Logical channel configuration, Radio bearer admission control, Split bearer and PDCP duplication control, etc. + +- Radio Resource Allocation Policy, used to modify the behaviour of call processes related to DRX, SR, SPS, Configured Grant, CQI table, Slice level PRB quota, etc. +- Connected Mode Mobility Policy, used to modify the behaviour of call processes related to HO, CHO, DAPS HO, etc. for both serving and target RAN nodes. +- Radio Access Policy, used to modify the behaviour of call processes related to RACH back-off, RRC connection reject, RRC connection release, Access barring, UE admission, etc. +- Dual Connectivity (DC) Policy, used to modify the behaviour of call processes related to DC related operations for both master and secondary RAN nodes, Change of bearer termination point (MN or SN) and/or bearer types, etc. +- Carrier Aggregation (CA) Policy, used to modify the behaviour of call processes related to CA related operations for both primary and secondary cells. +- Idle Mode Mobility Policy, used to modify the behaviour of call processes related to intra-frequency, inter-frequency, inter-RAT cell reselection priority, inactivity timers, etc. +- Measurement Report (MR) Configuration Policy, used to configure policy for RRC measurement objects, reporting objects, etc. +- Beamforming Configuration Policy, used to configure policy for Non-GoB and GoB Beamforming Mode. + +### 6.2.5 QUERY service + +The “RAN Control” RAN Function provides support of the following **QUERY** services: + +- E2 Node related Information retrieval between Near-RT RIC and E2 Node for any data required at Near-RT RIC +- UE related Information retrieval between Near-RT RIC and E2 Node for any data required at Near-RT RIC + +## 6.3 REPORT service description + +The E2SM-RC REPORT service requirements defined in Clause 6.2.1 are offered using a set of REPORT Styles. All REPORT styles are implemented using a set of IEs for Action Definition, RIC Indication Header and RIC Indication Message and have specific Event Trigger approach. For each Report style, a single RAN Parameter table is used to specify the required information to be reported. + +The following REPORT styles are supported: + +- Message copy: This REPORT style is initiated by “Message Event” Event Trigger and is used to report complete NI or RRC message along with UE associated information when the event trigger conditions are satisfied. +- Call Process Outcome: This REPORT style is initiated by the corresponding "Call Process Breakpoint" Event Trigger and is used to report on the outcome of a call process providing information on current, and in certain cases previous, UE or E2 Node information depending upon the nature of the target call process. +- E2 Node Information: This REPORT style is initiated by “E2 Node Information Change” Event Trigger and is used to report cell related and E2 Node related information upon event trigger conditions are satisfied. +- UE information: This REPORT style is initiated by “UE Information Change” Event Trigger and is used to report UE related information and UE state variables upon the event trigger conditions are satisfied. + +## 6.4 INSERT service description + +The E2SM-RC INSERT service requirements defined in Clause 6.2.2 are offered using a set of INSERT Styles. Each style corresponds to a set of “INSERT Indications”, where each “INSERT Indication” deals with a specific functionality and has a set of associated RAN parameters, provided in a mapping table. All INSERT Service styles are implemented using a set of IEs that constitute “Action Definition”, “RIC Indication Header” and “RIC Indication Message” to deliver RAN Control-related INSERT services. Each INSERT service style is associated with a specific “Event Trigger” + +approach. An “INSERT Indication” is used to request the RIC to control a functionality associated with the respective INSERT service style, and to set or modify the values of one or more associated RAN parameters. + +As an example, upon the arrival of an RRC Measurement Report in the E2 node due to the occurrence of an A3 event pertaining to a UE (which constitutes the event trigger), the E2 node can send a message to the RIC using the “Connected Mode Mobility Control Request” INSERT service style and the “Handover Control Request” INSERT Indication along with the “target cell ID” parameter. This RIC should then accept/deny the “Handover Control Request”, and if it accepts, it should set the value of the “target cell ID” parameter and send a CONTROL action back to the E2 Node. Up until then, the E2 node suspends the ongoing call processing for the UE. + +## 6.5 CONTROL service description + +The E2SM-RC CONTROL service requirements defined in Clause 6.2.3 are offered using a set of CONTROL Styles. Each style corresponds to a set of “CONTROL Action”, where each “CONTROL Action” deals with a specific functionality and has a set of associated RAN parameters, provided in a mapping table. All CONTROL Service styles are implemented using a set of IEs constituting a “RIC Control Request Header” and a “RIC Control Request Message” to deliver RAN Control-related CONTROL services and the optional “RIC Control Outcome” to carry control process outcome information from the E2 Node. A “CONTROL Action” containing one or more RAN parameters and their associated values can either be sent from the RIC, either asynchronously to the E2 node or as a response to a previous “INSERT Indication” from the E2 node. + +Referring to the previous example in Clause 6.4, the RIC sends a “CONTROL action” that accepts/denies the incoming “INSERT Indication” requesting for “Handover Control”, along with the value of the “Target Primary Cell”. As another example, the RIC can also asynchronously send a “CONTROL action” asking the E2 node to configure the UE in Carrier Aggregation mode and setup one or more secondary cells to the UE, whose values are assigned by the RIC via the “CONTROL action”. + +## 6.6 POLICY service description + +### 6.6.1 Overview + +The E2SM-RC POLICY service requirements defined in Clause 6.2.4 are offered using a set of POLICY Styles. Each style is implemented using multiple “Policy Approach” strategies, each with a specific methodology defined to use the E2AP IE “Action Definition” to deliver RAN Control related POLICY services. + +The following Policy Approaches are defined: + +- Control: POLICY for a given Style and Action ID is defined as a single case of a specific Policy condition with the corresponding Policy Action defined using the same data structure as CONTROL which would be used to replace default RAN behaviour. +- Offset: POLICY for a given Style and Action ID is defined as a set of different cases applicable for a range of different Policy conditions with the corresponding Policy Action defined using the dedicated data structure defined for POLICY which would be used to modify default RAN behaviour. + +### 6.6.2 Policy approach “Control” + +The “control” Policy Approach is similar to the CONTROL service, with static conditions and actions in the RIC Subscription used to select an appropriate CONTROL Action. When a set of Policy conditions are satisfied, then E2 Node is instructed to execute a Policy Action with a set of supplementary or default set of RAN parameters. + +A single Policy Action shall be a result of execution of multiple policy conditions. + +- Each Policy Condition is defined using a combination of RAN Parameters and conditional tests associated with UE and Call process related information. +- Each Policy Action is defined with a single Policy Action ID (command) which instructs E2 Node to perform a certain action when the conditions are satisfied. The Policy Action ID shall be supplemented with a set of RAN Parameters which may be used to provide information on default values to E2 Node. The Policy Decision indicates to the E2 Node, whether to accept or reject a RRM function, when the Policy conditions are met. + +Examples include: + +- Connected mode mobility policy, Handover Execution: Message Arrival breakpoint event trigger is defined to initiate the Policy service. On the arrival of A3 Measurement Report, the Policy service kicks in. Policy service installs a set of Policy Conditions like $RSRP > 'x'_{db} + Target\ Node\ Load < 'x'_{value} + Number\ of\ successful\ HO\ to\ target\ Node > 'x'_{value}$ . When these Policy conditions are satisfied, then perform Policy Action - "Execute HO" defined in the CONTROL service in Clause 6.5. The Policy Action may be provided as a standalone Policy Action ID "Execute HO" without any RAN parameters. As an alternative, Policy Action "Execute HO" may be supplemented with default RAN parameters like Handover only QCI 5 and 9 bearers. +- Carrier Aggregation Policy, CA Release decision: A call process breakpoint event trigger is defined to initiate the POLICY service. The call process breakpoint shall define conditions for Buffer occupancy. A call process breakpoint event shall be triggered when the Buffer Occupancy (BO) $< 'x'_{KB}$ . In this scenario, the event trigger satisfies the Policy condition. Hence there is no need to define a Policy condition in the Policy service, When the $BO < 'x'_{KB}$ kicks in, then Policy Action shall instruct E2 Node to "Release Scell". + +### 6.6.3 Policy Approach "Offset" + +The "offset" Policy Approach is based on the design assumption that the *Policy Action* IE is used to carry one or more RAN Parameters that are used to modify default E2 Node behaviour via the addition of an "offset" to be applied to given target threshold or other parameter used in the target call process. + +The applicable Policy Action is dependent upon a set of Policy Conditions and a given POLICY service may support one or more Policy conditions and so provide a targeted Policy Action for a range of different specific cases, each defined using a unique Policy condition where: + +- Each Policy Condition is defined using a combination of RAN Parameters and conditional tests associated with UE and Call process related information. The first positive match in a list of Policy conditions is used to select the corresponding Policy Action. +- Each Policy Action is defined using a list of RAN Parameters of data type INTEGER or REAL which may be used directly for default values of type INTEGER or REAL (i.e. Default+Offset) and indirectly to for default values of type ENUMERATED (i.e. select value in list that is Offset before or after default value). + +Examples include: + +- Connected mode mobility policy, Handover decision: A call process breakpoint event trigger is defined to initiate the POLICY service from within the call process handling UE measurement reports related to handover decisions for a specific target Slice and primary cell currently subject to Traffic Steering guidance. The Policy conditions list of RAN Parameters supports the definition of different A3 measurement threshold criteria offset values to be applied to UEs with a specific combination of slice ID, active QoS bearers, velocity and throughput and subject to overall E2 Node load and cell level load balancing requirements. Handover is accepted if the reported A3 measurement is greater than the default A3 measurement threshold+offset. +- Carrier Aggregation Policy, CA release decision: A call process breakpoint event trigger is defined to initiate the POLICY service from within the call process related to Carrier Aggregation (CA) release decisions for a specific target Slice currently subject to QoE guidance. The Policy conditions list of RAN Parameters supports the definition of different CA release threshold criteria offset values to be applied to UEs with a specific combination of slice ID, active QoS bearers, velocity and throughput and subject to overall E2 Node load and cell level load balancing requirements. CA release is initiated if the UE throughput is less than the default UE throughput threshold+offset. + +## 6.7 QUERY service description + +The E2SM-RC QUERY service requirements defined in Clause 6.2.5 are offered using a set of QUERY Styles. All QUERY styles are implemented using a set of IEs for RIC Query Header, RIC Query Definition and RIC Query Outcome. For each Query style, a single RAN Parameter table is used to specify the required information to be requested and responded. + +# 7 RAN Function Description + +## 7.1 RAN Function Definition + +The E2AP [3] procedures E2 Setup and RIC Service Update are used to transport the *RAN Function Definition* IE. + +For a specific RAN Function declared using E2SM-RC, the *RAN Function Definition* IE, defined in clause 9.2.2, shall report the following information: + +- RAN Function name along with associated information on E2SM definition +- Event trigger styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **REPORT** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **INSERT** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **CONTROL** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **POLICY** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **QUERY** Service styles list along with the corresponding encoding type for each associated E2AP IE. + +For the case where *RAN Function Definition* IE, defined in clause 9.2.2, is present in the E2 SETUP REQUEST message the IE shall provide a complete list of all Styles, Actions and associated Formats and RAN Parameter for all supported RIC services reflecting the current status of the RAN Function. + +For the case where *RAN Function Definition* IE, defined in clause 9.2.2, is present in the RIC SERVICE UPDATE message within the E2AP *RAN Functions Added List* IE, the IE shall provide a complete list of all Styles, Actions and associated Formats and RAN Parameter for all supported RIC services for the newly added RAN Function with a new RAN Function ID. + +For the case where *RAN Function Definition* IE, defined in clause 9.2.2, is present in the RIC SERVICE UPDATE message within the E2AP *RAN Functions Modified List* IE, the IE shall provide a complete list of all the Styles, Actions and associated Formats and RAN Parameter for all supported RIC services including both modified and unchanged information for an existing RAN Function. + +## 7.2 RAN Function name + +RAN Function Short Name “ORAN-E2SM-RC” + +RAN Function name description “RAN Control” + +RAN Function Instance, required when and if E2 Node exposes more than one instance of a RAN Function based on this E2SM. + +## 7.3 RIC Event Trigger Definition IE styles + +### 7.3.1 RIC Event Trigger Definition IE style list + +| RIC Style Type | Style Name | Supported RIC Service Style | | | Style Description | +|----------------|----------------------------|-----------------------------|--------|--------|------------------------------------------------------------------------------------------------------| +| | | Report | Insert | Policy | | +| 1 | Message Event | 1 | - | 1-7 | Triggering conditions are based on arrival or departure of network interface message or RRC message. | +| 2 | Call Process Breakpoint | 2 | 1-7 | 1-8 | Triggering conditions are based on call process breakpoint. | +| 3 | E2 Node Information Change | 3 | - | - | Triggering conditions are based on change of E2 Node or cell related configuration information. | +| 4 | UE Information Change | 4 | - | 9 | Triggering conditions are based on change of UE Information. | + +### 7.3.2 RIC Event Trigger Definition IE style 1: Message Event + +This *RIC Event Trigger Definition* IE style is used to detect a specific Network Interface or RRC message event in E2 Node. The detection can be based on only for incoming or outgoing message. The E2 Node can also be configured to detect multiple messages simultaneously and to trigger only when all the configured message events happen or for any logical combination of message events. + +Each message event configured can be further conditioned to be associated only for a certain UE or group of UEs as indicated by the *Associated UE Info* IE if included, or only for some specific UE events defined in Clause 8.1.5 as indicated by the *Associated UE Event* IE if included. In case that the *Global Associated UE Info* IE is included, the information is applied uniformly to all the message events configured and the IE shall override any *Associated UE Info* IE included for some message events. + +For each message event configured, Event Trigger Condition ID is assigned so that E2 Node can reply to Near-RT RIC in the RIC INDICATION message to inform which event(s) are the cause for triggering. + +This *RIC Event Trigger Definition* IE style uses *RIC Event Trigger Definition* IE Format 1 (9.2.1.1.1). + +### 7.3.3 RIC Event Trigger Definition IE style 2: Call Process Breakpoint + +This *RIC Event Trigger Definition* IE style is used to detect a call process in E2 Node based on a specified call process identifier and breakpoint identifier. The call process and breakpoint configured for event triggering can also be conditioned to be associated with a certain E2 Node related information. + +The following table specifies the supported call process types, call breakpoints, the associated RAN Parameters for possible E2 Node related conditioning for event triggering, as well as the supported INSERT or POLICY services. + +| Call Process Type ID | Call Process Type | Call Breakpoint ID | Call Breakpoint Name | Associated RAN Parameters | Supported INSERT Service Styles | Supported POLICY Service Styles | Supported REPORT Service Styles | Description | +|----------------------|---------------------------|--------------------|-------------------------|---------------------------|---------------------------------|---------------------------------|---------------------------------|------------------------------------------------------------| +| 1 | UE Context Management | 1 | UE Context Setup | 8.1.2.1.1 | 1,2,3,4,6,7 | 1,2,3,4,6,7,8 | 2 | TS 38.470 [18] clause 5.2.3 and TS 38.410 [10] clause 5.3. | +| | | 2 | UE Context Modification | 8.1.2.1.2 | | | | | +| | | 3 | UE Context Release | 8.1.2.1.3 | | | | | +| 2 | Bearer Context Management | 1 | Bearer Context Setup | 8.1.2.2.1 | 1,4,5,6 | 1,4,5,6,8 | 2 | TS 38.460 [20] clause 5.1.2 | +| | | 2 | Bearer Context | 8.1.2.2.2 | | | | | + +| | | | | | | | | | +|---|----------------------------------------|---|------------------------------------|-----------|---------|-----------|---|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | Modification | | | | | | +| | | 3 | Bearer Context Release | 8.1.2.2.3 | | | | | +| 3 | Mobility Management | 1 | Handover Preparation | 8.1.2.3.1 | 3 | 3,8 | 2 | TS 38.420 [14] clause 5.2.2 and TS 38.410 [10] clause 5.4. It also handles the F1AP: Mobility Management aspects of the <i>UE Context Management</i> procedure from TS 38.470 and TS 38.473 | +| | | 2 | Handover Cancel | 8.1.2.3.2 | | | | | +| | | 3 | Handover Resource Allocation | 8.1.2.3.3 | | | | | +| 4 | Multi-RAT Dual Connectivity Management | 1 | SN Addition | 8.1.2.4.1 | 5 | 5,8 | 2 | TS 38.420 [14] clause 5.2.3 and TS 36.420 [16] clauses 5.2.1.5 and 5.2.1.6 | +| | | 2 | SN Modification and Release | 8.1.2.4.2 | | | | | +| 5 | Radio Resource Control Management | 1 | RRC CG-Config Information Transfer | 8.1.2.5.1 | 1-7 | 1-7 | 2 | TS 38.470 [18] clause 5.2.4, TS 38.331 [22]. | +| | | 2 | RRC Cell Group Config Transfer | 8.1.2.5.2 | | | | | +| | | 3 | RRC Measurement Configuration | 8.1.2.5.3 | NA | 8 | 2 | | +| 6 | PDU Session Management | 1 | PDU Session Resource Setup | 8.1.2.6.1 | 1,3,4,5 | 1,3,4,5,8 | 2 | TS 38.410 [10] clause 5.5 | +| | | 2 | PDU Session Resource Modification | 8.1.2.6.2 | | | | | +| | | 3 | PDU Session Resource Release | 8.1.2.6.3 | | | | | + +**Table 7.3.3-1: RIC Event Trigger Definition IE style 2 – Supported Call Processes and associated RAN Parameters** + +Each event configured can be further conditioned to be associated only for a certain UE or group of UEs as indicated by the *Associated UE Info* IE if included. + +This *RIC Event Trigger Definition* IE style uses *E2SM-RC Event Trigger Definition Format 2* IE (9.2.1.1.2). + +### 7.3.4 RIC Event Trigger Definition IE style 3: E2 Node Information Change + +This *RIC Event Trigger Definition* IE style is used to detect E2 Node related information change from the subscribed E2 Node. The E2 Node can also be configured to detect multiple changes simultaneously and to trigger only when all the configured changes happen or for any logical combination of the configured changes. + +In this version of E2SM-RC specification, the following E2 Node related information changes are supported for event triggering. + +| E2 Node Information Change ID | E2 Node Information Change Type | Description | +|-------------------------------|-----------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell Configuration Change | Triggered when any serving cell's context information defined by the <i>Served Cell Information</i> IE in TS 38.473 [19] clause 9.3.1.10 has changed. | +| 2 | Cell Neighbour Relation Change | Triggered when any serving cell's neighbour relation information defined by Clause 9.3.38 has changed. | +| 3 | Slice Configuration Change | Triggered when slice configuration in any serving cell has changed. | +| 4 | MIB Change | Triggered when the MIB in any serving cell has changed | +| 5 | Serving Cell Config Common Change | Triggered when any Serving Cell Config Common information defined by Section 8.2.3 in any serving cell has changed | + +**Table 7.3.4-1: RIC Event Trigger Definition IE style 3 – Supported E2 Node information changes** + +Each E2 Node information change configured can also be conditioned to be associated with a specific cell or group of cells for event triggering, as indicated by the *Associated Cell Info* IE if included. + +For each information change configured for event triggering, Event Trigger Condition ID is also assigned so that E2 Node can reply to Near-RT RIC in the RIC INDICATION message to inform which event(s) are the cause for triggering. + +This *RIC Event Trigger Definition* IE style uses *E2SM-RC Event Trigger Definition Format 3* IE (9.2.1.1.3). + +### 7.3.5 RIC Event Trigger Definition IE style 4: UE Information Change + +This *RIC Event Trigger Definition* IE style is used to detect UE Context related information change from the subscribed E2 Node. The E2 Node can also be configured to detect multiple changes simultaneously and to trigger only when all the configured changes happen or for any logical combination of the configured changes. + +In this version of E2SM-RC specification, the supported UE Context information changes for event triggering are + +- RRC state change +- UE identifier change (based on UE ID defined in Clause 9.3.10) +- RLC/PDCP state variable or MAC state variable change (based on RAN Parameters defined in Clauses 8.1.1.4 and 8.1.1.8) +- L2 MAC scheduler-related changes (e.g. MIMO transmission mode state change for the UE, etc.) +- UE context info change + +For UE identifier change, the following cases are supported for event triggering. + +| UE Identifier Change ID | UE Identifier Change Type | Description | +|-------------------------|---------------------------|-------------------------------------------------------------------------------------------------------------------| +| 1 | New UE Connected | Triggered when new UE ID is assigned for a new UE connected. | +| 2 | UE Handed Over | Triggered when new UE ID is assigned due to HO from another node. | +| 3 | UE ID Changed | Triggered when any content of the assigned UE ID (based on the definition of UE ID in Clause 9.3.10) has changed. | +| 4 | UE ID Removed | Triggered when a UE is released, and its UE ID is removed. | + +**Table 7.3.5-1: RIC Event Trigger Definition IE style 4 – Supported UE Information changes** + +The detection for each UE information change configured can be based on for any UEs, or only for a certain UE or group of UEs as indicated by the *Associated UE Info* IE if included. + +For each information change configured, Event Trigger Condition ID is assigned so that E2 Node can reply to Near-RT RIC in the RIC INDICATION message to inform which event(s) are the cause for triggering. + +This *RIC Event Trigger Definition* IE style uses *E2SM-RC Event Trigger Definition Format 4* IE (9.2.1.1.4). + +## 7.4 Supported RIC REPORT Services + +### 7.4.1 REPORT Service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|----------------------|--------------------------------------------------------------------------------------------------------------------------| +| 1 | Message copy | This style is used to report a copy of complete Network Interface or RRC message. | +| 2 | Call Process Outcome | This style is used to report the outcome of an ongoing call process. | +| 3 | E2 Node Information | This style is used to report E2 Node information, Serving Cell Configuration and Neighbour Relation related information. | +| 4 | UE Information | This style is used to report the UE related information like PDCP, RLC, MAC UE state variables and RRC UE State. | + +### 7.4.2 REPORT Service Style 1: Message Copy + +#### 7.4.2.1 REPORT Service Style description + +This **REPORT** Service style provides the complete copy of a Network Interface or RRC message to be carried as a transparent container in the *RIC Indication Message* IE. + +This **REPORT** service style may also be used to report UE and E2 Node specific information associated with the Network Interface/RRC messages as provided in Clause 8.2.1 RAN Parameters. Examples include reporting of UEID to Near-RT RIC when UE attaches to the E2 Node or when the UEID changes during Xn Handover, UE events like Secondary Cell addition, Arrival of A3 Measurement Report (see Clause 8.1.5 for the list of UE events). + +This **REPORT** Service style is initiated by Event Trigger style 1: Message Event. + +#### 7.4.2.2 REPORT Service *RIC Action Definition* IE contents + +The Action Definition for this service style is used to request E2 Node to report a copy of NI and/or RRC message and may be used to report UE and E2 Node specific information. The action definition indicates which related UE and E2 Node information is to be reported along with the NI or RRC message that triggers this report service. + +This **REPORT** Service style uses the *E2SM-RC Action Definition Format 1* IE (9.2.1.2.1). The supported Parameters for this format are provided in Clause 8.2.1. + +#### 7.4.2.3 REPORT Service *RIC Indication Header* IE contents + +This **REPORT** Service style uses the *E2SM-RC Indication Header Format 1* IE (9.2.1.3.1) + +#### 7.4.2.4 REPORT Service *RIC Indication Message* IE contents + +The **REPORT** Service *RIC Indication Message* IE carries the complete Network Interface or RRC message as transparent containers. The *RIC Indication Message* IE may also carry UE and E2 Node specific information related to the Network Interface or RRC message as provided in Clause 8.2.1. + +This **REPORT** Service style uses the *E2SM-RC Indication Message Format 1* IE (9.2.1.4.1). The supported Parameters for this message format are provided in Clause 8.2.1. + +### 7.4.3 REPORT Service Style 2: Call Process Outcome + +#### 7.4.3.1 REPORT Service Style description + +This **REPORT** Service style provides the outcome of a target call process related mechanism to be carried in the *RIC Indication Message* IE along with an associated *RIC Indication Header* IE providing information related event trigger conditions. + +This **REPORT** Service style is initiated by Event Trigger style 2: Call Process Breakpoint. + +#### 7.4.3.2 REPORT Service *RIC Action Definition* IE contents + +The Action Definition for this service style is used to request an E2 Node to report call process outcome information including UE specific information. The Action Definition indicates which related UE information is to be reported related to the outcome of the event that triggers this report service. + +This **REPORT** Service style uses the *E2SM-RC Action Definition Format 1* IE (9.2.1.2.1). The supported Parameters for this message format are provided in Clause 8.2.2. + +#### 7.4.3.3 REPORT Service *RIC Indication Header* IE contents + +This **REPORT** Service style uses the *E2SM-RC Indication Header Format 1* IE (9.2.1.3.1). + +#### 7.4.3.4 REPORT Service *RIC Indication Message* IE contents + +The **REPORT** Service *RIC Indication Message* IE carries the UE specific information as a result of call process outcome. The Parameters supporting UE specific information is provided in Clause 8.2.2. + +This **REPORT** Service style uses the *E2SM-RC Indication Message Format 2* IE (9.2.1.4.2). The supported Parameters for this message format are provided in Clause 8.2.2. + +### 7.4.4 REPORT Service Style 3: E2 Node Information. + +#### 7.4.4.1 REPORT Service Style description + +This **REPORT** Service style provides essential RAN control related E2 Node Configuration Information that is not provided by E2AP [3]. The information is carried in the *RIC Indication Message* IE along with an associated *RIC Indication Header* IE providing information related event trigger conditions. The required information to be provided is controlled using the associated *RIC Action Definition* IE parameters. + +This **REPORT** Service style provides information related to: + +- Serving Cell configuration +- Neighbour Relation Information + +whenever the corresponding event trigger for change in information content is satisfied. With every change in the information content of the Neighbour Relation Information, complete list of Neighbour relation table of the affected serving cell is sent to Near-RT RIC with indication on the modified information. + +This **REPORT** Service style is initiated by Event Trigger style 3: E2 Node Information Change. + +#### 7.4.4.2 REPORT Service *RIC Action Definition* IE contents + +The Action Definition for this service style indicates the E2 Node related information requested by Near-RT RIC. + +The **REPORT** Service style uses the *E2SM-RC Action Definition Format 1* IE (9.2.1.2.1). The supported Parameters for this format are provided in Clause 8.2.3. + +With every change in the information content of the Neighbour Relation Information pertaining to any cell in the E2 node (event trigger), the *RIC Action Definition* IE from the Near-RT RIC instructs the E2 node to send the complete list of Neighbour relation table for the impacted cell. + +#### 7.4.4.3 REPORT Service *RIC Indication Header* IE contents + +This **REPORT** Service style uses the *E2SM-RC Indication Header Format 1* IE (9.2.1.3.1). + +#### 7.4.4.4 REPORT Service *RIC Indication Message* IE contents + +The **REPORT** Service *RIC Indication Message* IE carries the E2 node related information as subscribed by the *RIC Action Definition* IE. + +This **REPORT** Service style uses the *E2SM-RC Indication Message Format 3* IE (9.2.1.4.3). The mapping of RAN parameters configured in the *RIC Action Definition* IE to the reported IEs in the *RIC Indication Message* IE Format 3 is provided in the semantics description of the IEs. + +### 7.4.5 REPORT Service Style 4: UE Information + +#### 7.4.5.1 REPORT Service Style description + +This **REPORT** Service style provides UE related Information. The information is carried in the *RIC Indication Message* IE along with an associated *RIC Indication Header* IE providing information related event trigger conditions. The required information to be provided is controlled using the associated *RIC Action Definition* IE parameters. + +This **REPORT** Service style enables the E2 Node to report on a per UE basis: + +- L2 UE State variable values including + - PDCP UE State variables + - RLC UE State variables + - MAC UE variables. +- L3 UE State variable values including + - RRC State + - UE ID Information +- UE ID change information including + - Current UE ID + - Old UE ID + - NI or RRC message which triggered the UE ID change +- UE context related information + +This **REPORT** Service style is initiated by Event Trigger style 4: UE Information Change. + +#### 7.4.5.2 REPORT Service *RIC Action Definition* IE contents + +The Action Definition for this service style indicates the set of UE information parameters to be reported when event trigger to report is satisfied. + +The **REPORT** Service style uses the *E2SM-RC Action Definition Format 1* IE (9.2.1.2.1). The supported Parameters for this message format are provided in Clause 8.2.4. + +#### 7.4.5.3 REPORT Service *RIC Indication Header* IE contents + +This **REPORT** Service style uses the *E2SM-RC Indication Header Format 1* IE (9.2.1.3.1). + +#### 7.4.5.4 REPORT Service *RIC Indication Message* IE contents + +The **REPORT** Service *RIC Indication Message* IE carries the requested UE related information. + +This **REPORT** Service style uses the *E2SM-RC Indication Message Format 2* IE (9.2.1.4.2). The supported Parameters for this message format are provided in Clause 8.2.4. + +## 7.5 Supported RIC INSERT Services + +### 7.5.1 INSERT Service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|-------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Radio Bearer Control Request | Used to request modification of the configuration of Radio Bearer Control (RBC) related parameters.<br>Belongs to Fundamental level INSERT Services. | +| 2 | Radio Resource Allocation Control Request | Used to request modification of the configuration of Radio Resource Allocation control related parameters.<br>Belongs to Fundamental level INSERT Services. | +| 3 | Connected Mode Mobility Control Request | Used to request initiation of a connected mode mobility procedure (Handover or Conditional Handover), optionally with Dual Active Protocol Stack (DAPS), for a specific UE towards either a target cell (for HO) or a list of candidate cells (for CHO).<br>Belongs to Fundamental level INSERT Services. | +| 4 | Radio Access Control Request | Used to request modification of radio access related functions for controlling UE access to cells.<br>Belongs to Fundamental level INSERT Services. | +| 5 | Dual Connectivity Control Request | Used to request initiation of dual connectivity (DC) mechanisms<br>Belongs to Fundamental level INSERT Services. | +| 6 | Carrier Aggregation Control Request | Used to request initiation of carrier aggregation (CA) mechanisms<br>Belongs to Fundamental level INSERT Services. | +| 7 | Idle Mode Mobility Control Request | Used to request modification of idle mode mobility related functions in order to control UE re-selection of cells<br>Belongs to Fundamental level INSERT Services. | +| 255 | Multiple Actions Control Request | Used to request multiple parallel actions of the selected fundamental level INSERT Service style(s).<br>Belongs to Integrated level INSERT Services. | + +Apart from the individual set of RAN parameters associated with each INSERT Service style and INSERT Indication name as described in Clauses 7.5.2 to 7.5.8, there is also a common set of RAN parameters for all INSERT service styles as elucidated in Clause 8.3.9. + +### 7.5.2 INSERT Service Style 1: Radio Bearer Control Request + +#### 7.5.2.1 INSERT Service Style description + +This **INSERT** Service style provides a mechanism to initiate request to the RIC for controlling the functionalities of a radio bearer related process pertaining to a UE using the *RIC Indication Message* IE and associated *RIC Indication* + +**Header IE.** The E2 node sends a *RIC Indication* message to the near-RT RIC and the ongoing call process is suspended at the E2 node until the E2 node hears back from the RIC. The optional *RIC Call Process ID* IE is used by the E2 node to match a *RIC Control Request* message to a *RIC Indication* message, following which the E2 node can resume the suspended call processing for the UE. + +Applications of this service include: + +- Request for DRB QoS Modification, to tune DRB level QoS related parameters to meet the QoS optimization targets. +- Request for QoS Flow (re)mapping, to adjust the mapping relationship between QoS flows and DRBs. +- Request for Logical channel (re)configuration +- Request for Radio Bearer Admission Control, to configure DRB admission control such as reject or release may be applied. +- Request for Split bearer and PDCP duplication control + +This Insert style supports the following *Indication* services, each service listed below with a corresponding *Indication* ID. The RAN parameters, associated with each Insert Indication service, are listed in the sections shown below. + +| Indication ID | Indication Name | Insert Indication description | Associated RAN Parameters | +|---------------|----------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| +| 1 | DRB QoS Configuration request | To request the configuration of DRB QoS profile | 8.3.2.1 | +| 2 | QoS flow mapping configuration request | To request the multiplexing of QoS flows to a DRB (addition, modification, deletion) | 8.3.2.2 | +| 3 | Logical channel configuration request | To request the LCID configuration of a DRB | 8.3.2.3 | +| 4 | Radio admission control request | To request radio admission control of a UE | 8.3.2.4 | +| 5 | DRB termination control request | To request a change in the bearer termination point | 8.3.2.5 | +| 6 | DRB split ratio control request | To request the split ratio of a DRB to be controlled across its RLC entities | 8.3.2.6 | +| 7 | PDCP Duplication control request | To request controlling the activation or de-activation of PDCP duplication for a DRB and control/configure the number of legs or RLC entities for the DRB | 8.3.2.7 | + +#### 7.5.2.2 INSERT Service *RIC Action Definition* IE contents + +This **INSERT** Service style uses the *E2SM-RC Action Definition Format 3* IE (9.2.1.2.3). This Insert style deals with the supported *Indication* services, each service with a corresponding *Indication* ID listed in Clause 7.5.2.1. The RAN parameters, associated with each Insert *RIC Indication* service, are included by the E2 node in the *RIC Indication* message. Via the *RIC Indication* message, the E2 node seeks the near-RT RIC to accept or deny the request raised by the E2 node and to accordingly set the values for the associated RAN parameters by the RIC via the control action in the ensuing *RIC Control Request* message from the RIC. + +#### 7.5.2.3 INSERT Service *RIC Indication Header* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication header Format 2* IE (9.2.1.3.2). The *RIC Indication Header* IE has the UE ID, the *Insert Service Style* ID and the corresponding *Insert Indication* ID. + +#### 7.5.2.4 INSERT Service *RIC Indication Message* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Message Format 5* IE (9.2.1.4.5). The *RIC Indication Message* IE includes a sequence of associated RAN parameters for which the E2 node seeks the near-RT RIC to accept/deny the request raised by the E2 node and accordingly set the values for the associated RAN parameters, via the control action in the ensuing *RIC Control Request* IE. + +#### 7.5.2.5 INSERT Service *RIC Call Process ID* IE contents + +This **INSERT** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +### 7.5.3 INSERT Service Style 2: Radio Resource Allocation Control Request + +#### 7.5.3.1 INSERT Service Style description + +This **INSERT** Service style provides a mechanism to initiate request to the RIC for controlling the allocation of radio resources to the UE using the *RIC Indication Message* IE and associated *RIC Indication Header* IE. The E2 node sends a *RIC Indication* message to the near-RT RIC and the ongoing call process is suspended at the E2 node until the E2 node hears back from the RIC. The optional *RIC Call Process ID* IE is used by the E2 node to match a *RIC Control Request* message to a *RIC Indication* message, following which the E2 node can resume the suspended call processing for the UE. + +Applications of this service include: + +- Request for Discontinuous Reception (DRX) control +- Request for Scheduling request (SR) control +- Request for Semi-Persistent Scheduling (SPS) control +- Request for Configured Grant control +- Request for Channel Quality Indicator (CQI) table +- Request for Slice level PRB quota + +This Insert style supports the following *Indication* services, each service listed below with a corresponding *Indication* ID. The RAN parameters, associated with each Insert Indication service, are listed in the sections shown below. + +| Indication ID | Indication Name | Insert Indication description | Associated RAN Parameters | +|---------------|--------------------------------------|-----------------------------------------------------------|---------------------------| +| 1 | DRX parameter configuration request | To request the configuration of DRX parameters | 8.3.3.1 | +| 2 | SR periodicity configuration request | To request the configuration of SR periodicity parameters | 8.3.3.2 | +| 3 | SPS parameters configuration request | To request the configuration of SPS parameters | 8.3.3.3 | +| 4 | Configured grant control request | To request the configuration of uplink grants to the UE | 8.3.3.4 | +| 5 | CQI table configuration request | To request the configuration of CQI table. | 8.3.3.5 | +| 6 | Slice-level PRB quota request | To request setting the slice-specific PRB quota | 8.3.3.6 | + +#### 7.5.3.2 INSERT Service *RIC Action Definition* IE contents + +This **INSERT** Service style uses the *E2SM-RC Action Definition Format 3* IE (9.2.1.2.3). The Insert style deals with the supported *Indication* services, each service with a corresponding *Indication* ID listed in Clause 7.5.3.1. The RAN parameters, associated with each Insert *Indication* service, are included by the E2 node in the *RIC Indication* message. Via the *RIC Indication* message, the E2 node seeks the near-RT RIC to accept or deny the request raised by the E2 node and to accordingly set the values for the associated RAN parameters by the RIC via the control action in the ensuing *RIC Control Request* message from the RIC. + +#### 7.5.3.3 INSERT Service *RIC Indication Header* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Header Format 2* IE (9.2.1.3.2). The *RIC Indication Header* IE has the UE ID, the *Insert* Service Style ID and the corresponding *Insert* Indication ID. + +#### 7.5.3.4 INSERT Service *RIC Indication Message* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Message Format 5* IE (9.2.1.4.5). The *RIC Indication Message* IE includes a sequence of associated RAN parameters for which the E2 node seeks the near-RT RIC to accept/deny the request raised by the E2 node and accordingly set the values for the associated RAN parameters, via the control action in the ensuing *RIC Control Request* IE. + +#### 7.5.3.5 INSERT Service *RIC Call Process ID* IE contents + +This **INSERT** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +### 7.5.4 INSERT Service Style 3: Connected Mode Mobility Control Request + +#### 7.5.4.1 INSERT Service Style description + +This **INSERT** Service style provides a mechanism to initiate request for controlling the handover and mobility management of the UE using the *RIC Indication Message* IE and associated *RIC Indication Header* IE. The E2 node sends a *RIC Indication* message to the near-RT RIC and the ongoing call process is suspended at the E2 node until the E2 node hears back from the RIC. The optional *RIC Call Process ID* IE is used by the E2 node to match a *RIC Control Request* message to a *RIC Indication* message, following which the E2 node can resume the suspended call processing for the UE. + +Applications of this service include: + +- Request for Handover (HO) initiation for a selected UE towards a target cell +- Request for Conditional handover (CHO) initiation for a selected UE towards a list of candidate cell(s) +- Request for Handover (HO) initiation with Dual Active Protocol Stack (DAPS) for a selected UE towards a target cell + +This Insert style supports the following *Indication* services, each service listed below with a corresponding *Indication* ID. The RAN parameters, associated with each Insert Indication service, are listed in the sections shown below. + +| Indication ID | Indication Name | Insert Indication description | Associated RAN parameters | +|---------------|--------------------------------------|---------------------------------------------------------------------------------------|---------------------------| +| 1 | Handover Control request | To request the handover of the primary cell and subsequent secondary cell reselection | 8.3.4.1 | +| 2 | Conditional Handover Control request | To request the conditional handover involving target primary cells | 8.3.4.2 | + +| | | | | +|---|------------------------------------------------------------|---------------------------------------------------------------------------------------|---------| +| 3 | DAPS (Dual Active Protocol Stack) Handover Control request | To request the dual active protocol stack handover involving the target primary cell. | 8.3.4.3 | +|---|------------------------------------------------------------|---------------------------------------------------------------------------------------|---------| + +#### 7.5.4.2 INSERT Service *RIC Action Definition* IE contents + +This **INSERT** Service style uses the *E2SM-RC Action Definition Format 3* IE (9.2.1.2.3). The Insert style deals with the supported *Indication* services, each service with a corresponding *Indication* ID listed in Clause 7.5.4.1. The RAN parameters, associated with each Insert *RIC Indication* service, are included by the E2 node in the *RIC Indication* message. Via the *RIC Indication* message, the E2 node seeks the near-RT RIC to accept or deny the request raised by the E2 node and to accordingly set the values for the associated RAN parameters by the RIC via the control action in the ensuing *RIC Control Request* message from the RIC. + +#### 7.5.4.3 INSERT Service *RIC Indication Header* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Header Format 2* IE (9.2.1.3.2). The *RIC Indication Header* IE has the UE ID, the *Insert* Service Style ID and the corresponding *Insert* Indication ID. + +#### 7.5.4.4 INSERT Service *RIC Indication Message* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Message Format 5* IE (9.2.1.4.5). The *RIC Indication Message* IE includes a sequence of associated RAN parameters for which the E2 node seeks the near-RT RIC to accept/deny the request raised by the E2 node and accordingly set the values for the associated RAN parameters, via the control action in the ensuing *RIC Control Request* IE. + +#### 7.5.4.5 INSERT Service *RIC Call Process ID* IE contents + +This **INSERT** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +### 7.5.5 INSERT Service Style 4: Radio Access Control Request + +#### 7.5.5.1 INSERT Service Style description + +This **INSERT** Service style provides a mechanism to initiate request for controlling the radio access of the UE using the *RIC Indication Message* IE and associated *RIC Indication Header* IE. The E2 node sends a *RIC Indication* message to the near-RT RIC and the ongoing call process is suspended at the E2 node until the E2 node hears back from the RIC. The optional *RIC Call Process ID* IE is used by the E2 node to match a *RIC Control Request* message to a *RIC Indication* message, following which the E2 node can resume the suspended call processing for the UE. + +Applications of this service include: + +- Request for configuring RACH back-off +- Request for UE admission +- Request for RRC connection reject +- Request for RRC connection release Request for Access barring + +This Insert style supports the following *Indication* services, each service listed below with a corresponding *Indication* ID. The RAN parameters, associated with each Insert Indication service, are listed in the sections shown below. + +| Indication ID | Indication Name | Insert Indication Description | Associated RAN Parameters | +|---------------|------------------------------|-----------------------------------------------|---------------------------| +| 1 | UE Admission Control request | To request UE admission control. | 8.3.5.1 | +| 2 | RACH backoff control request | To request control of RACH backoff parameters | 8.3.5.2 | + +| | | | | +|---|--------------------------------|------------------------------------------------------------------|---------| +| 3 | Access barring control request | To request access barring configuration parameters configuration | 8.3.5.3 | +| 4 | RRC connection release | To request release of an RRC connection for a UE | 8.3.5.4 | +| 5 | RRC connection reject | To request rejection of an RRC connection for a UE | 8.3.5.5 | + +#### 7.5.5.2 INSERT Service *RIC Action Definition* IE contents + +This **INSERT** Service style uses the *E2SM-RC Action Definition Format 3* IE (9.2.1.2.3). The Insert style deals with the supported *Indication* services, each service with a corresponding *Indication* ID listed in Clause 7.5.5.1. The RAN parameters, associated with each Insert *Indication* service, are included by the E2 node in the *RIC Indication* message. Via the *RIC Indication* message, the E2 node seeks the near-RT RIC to accept or deny the request raised by the E2 node and to accordingly set the values for the associated RAN parameters by the RIC via the control action in the ensuing *RIC Control Request* message from the RIC. + +#### 7.5.5.3 INSERT Service *RIC Indication Header* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Header Format 2* IE (9.2.1.3.2). The *RIC Indication Header* IE has the UE ID, the *Insert* Service Style ID and the corresponding *Insert* Indication ID. + +#### 7.5.5.4 INSERT Service *RIC Indication Message* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Message Format 5* IE (9.2.1.4.5). The *RIC Indication Message* IE includes a sequence of associated RAN parameters for which the E2 node seeks the near-RT RIC to accept/deny the request raised by the E2 node and accordingly set the values for the associated RAN parameters, via the control action in the ensuing *RIC Control Request* IE. + +#### 7.5.5.5 INSERT Service *RIC Call Process ID* IE contents + +This **INSERT** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +### 7.5.6 INSERT Service Style 5: Dual Connectivity Control Request + +#### 7.5.6.1 INSERT Service Style description + +This **INSERT** Service style provides a mechanism to initiate request for controlling the dual connectivity of the UE using the *RIC Indication Message* IE and associated *RIC Indication Header* IE. The E2 node sends a *RIC Indication* message to the near-RT RIC and the ongoing call process is suspended at the E2 node until the E2 node hears back from the RIC. The optional *RIC Call Process ID* IE is used by the E2 node to match a *RIC Control Request* message to a *RIC Indication* message, following which the E2 node can resume the suspended call processing for the UE. + +Applications of this service include: + +- Request for Dual connectivity (EN-DC, MR-DC or NR-NR DC) initiation for a selected UE towards a target secondary cell (PScell) +- Request for Secondary cell change for a selected UE towards a target secondary cell (PScell) +- Request for Dual connectivity (EN-DC, MR-DC or NR-NR DC) modification for a selected UE +- Request for Dual connectivity (EN-DC, MR-DC or NR-NR DC) release initiation for a selected UE +- Request for Change of bearer termination point (MN or SN) and/or bearer types for a selected UE + +This Insert style supports the following *Indication* services, each service listed below with a corresponding *Indication* ID. The RAN parameters, associated with each Insert Indication service, are listed in the sections shown below. + +| Indication ID | Indication Name | Insert Indication Description | Associated RAN parameters | +|---------------|------------------------------------------------------------|---------------------------------------------------------------------------------------|---------------------------| +| 1 | DC Secondary Node Addition Control request | To request secondary node addition for dual connectivity | 8.3.6.1 | +| 2 | DC Secondary Node Modification and Release Control request | To request modification of secondary node for DC | 8.3.6.2 | +| 3 | DC PSCell Change control request | To request PSCell change of a UE within a secondary node or to another secondary node | 8.3.6.3 | +| 4 | DC Secondary Node Change Control request | To request changing the secondary node of a UE for DC | 8.3.6.4 | +| 5 | DC DRB termination control request | To request a change in the bearer termination point | 8.3.2.5 | + +#### 7.5.6.2 INSERT Service *RIC Action Definition* IE contents + +This **INSERT** Service style uses the *E2SM-RC Action Definition Format 3* IE (9.2.1.2.3). The Insert style deals with the supported *Indication* services, each service with a corresponding *Indication* ID listed in Clause 7.5.6.1. The RAN parameters, associated with each Insert *Indication* service, are included by the E2 node in the *RIC Indication* message. Via the *RIC Indication* message, the E2 node seeks the near-RT RIC to accept or deny the request raised by the E2 node and to accordingly set the values for the associated RAN parameters by the RIC via the control action in the ensuing *RIC Control Request* message from the RIC. + +#### 7.5.6.3 INSERT Service *RIC Indication Header* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Header Format 2* IE (9.2.1.3.2). The *RIC Indication Header* IE has the UE ID, the *Insert* Service Style ID and the corresponding *Insert* Indication ID. + +#### 7.5.6.4 INSERT Service *RIC Indication Message* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Message Format 5* IE (9.2.1.4.5). The *RIC Indication Message* IE includes a sequence of associated RAN parameters for which the E2 node seeks the near-RT RIC to accept/deny the request raised by the E2 node and accordingly set the values for the associated RAN parameters, via the control action in the ensuing *RIC Control Request* IE. + +#### 7.5.6.5 INSERT Service *RIC Call Process ID* IE contents + +This **INSERT** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +### 7.5.7 INSERT Service Style 6: Carrier Aggregation Control Request + +#### 7.5.7.1 INSERT Service Style description + +This **INSERT** Service style provides a mechanism to initiate request for controlling the carrier aggregation of the UE using the *RIC Indication Message* IE and associated *RIC Indication Header* IE. The E2 node sends a *RIC Indication* message to the near-RT RIC and the ongoing call process is suspended at the E2 node until the E2 node hears back from the RIC. The optional *RIC Call Process ID* IE is used by the E2 node to match a *RIC Control Request* message to a *RIC Indication* message, following which the E2 node can resume the suspended call processing for the UE. + +Applications of this service include: + +- Request for Carrier Aggregation (CA) initiation for a selected UE towards a target secondary cell or cells +- Request for Carrier Aggregation (CA) modification for a selected UE, or Secondary cell change for a selected UE towards a target secondary cell or cells +- Request for Carrier Aggregation (CA) release initiation for a selected UE + +This Insert style supports the following *Indication* services, each service listed below with a corresponding *Indication* ID. The RAN parameters, associated with each Insert Indication service, are listed in the sections shown below. + +| Indication ID | Indication Name | Insert Indication Description | Associated RAN parameters | +|---------------|------------------------------------------------------------|--------------------------------------------------------------------------------|---------------------------| +| 1 | CA Secondary Cell Addition Control request | To request control of the secondary cell addition for a UE | 8.3.7.1 | +| 2 | CA Secondary Cell Modification and Release Control request | To request control of the modification and release of secondary cells for a UE | 8.3.7.2 | + +#### 7.5.7.2 INSERT Service *RIC Action Definition* IE contents + +This **INSERT** Service style uses the *E2SM-RC Action Definition Format 3* IE (9.2.1.2.3). The Insert style deals with the supported *Indication* services, each service with a corresponding *Indication* ID listed in Clause 7.5.7.1. The RAN parameters, associated with each Insert *Indication* service, are included by the E2 node in the *RIC Indication* message. Via the *RIC Indication* message, the E2 node seeks the near-RT RIC to accept or deny the request raised by the E2 node and to accordingly, set the values for the associated RAN parameters by the RIC via the control action in the ensuing *RIC Control Request* message from the RIC. + +#### 7.5.7.3 INSERT Service *RIC Indication Header* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Header Format 2* IE (9.2.1.3.2). The *RIC Indication Header* IE has the UE ID, the *Insert Service Style* ID and the corresponding *Insert Indication* ID. + +#### 7.5.7.4 INSERT Service *RIC Indication Message* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Message Format 5* IE (9.2.1.4.5). The *RIC Indication Message* IE includes a sequence of associated RAN parameters for which the E2 node seeks the near-RT RIC to accept/deny the request raised by the E2 node and accordingly set the values for the associated RAN parameters, via the control action in the ensuing *RIC Control Request* IE. + +#### 7.5.7.5 INSERT Service *RIC Call Process ID* IE contents + +This **INSERT** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +### 7.5.8 INSERT Service Style 7: Idle Mode Mobility Control Request + +#### 7.5.8.1 INSERT Service Style description + +This **INSERT** Service style provides a mechanism to initiate request for controlling the idle mode mobility of the UE using the *RIC Indication Message* IE and associated *RIC Indication Header* IE. The E2 node sends a *RIC Indication* message to the near-RT RIC and the ongoing call process is suspended at the E2 node until the E2 node hears back from the RIC. The optional *RIC Call Process ID* IE is used by the E2 node to match a *RIC Control Request* message to a *RIC Indication* message, following which the E2 node can resume the suspended call processing for the UE. + +Applications of this service include: + +- Intra-frequency, inter-frequency, inter-RAT cell reselection priority + +##### - Idle timers + +This Insert style supports the following *Indication* services, each service listed below with a corresponding *Indication* ID. The RAN parameters, associated with each Insert Indication service, are listed in the sections shown below. + +| Indication ID | Indication Name | Insert Indication Description | Associated RAN parameters | +|---------------|------------------------------------|--------------------------------------------------------------------------------------------|---------------------------| +| 1 | Cell re-selection priority request | To request assignment of cell re-selection priorities for a UE during idle mode (RRC_IDLE) | 8.3.8.1 | + +#### 7.5.8.2 INSERT Service *RIC Action Definition* IE contents + +This **INSERT** Service style uses the *E2SM-RC Action Definition Format 3* IE (9.2.1.2.3). The Insert style deals with the supported *Indication* services, each service with a corresponding *Indication* ID listed in Clause 7.5.8.1. The RAN parameters, associated with each Insert *Indication* service, are included by the E2 node in the *RIC Indication* message. Via the *RIC Indication* message, the E2 node seeks the near-RT RIC to accept or deny the request raised by the E2 node and to accordingly, set the values for the associated RAN parameters by the RIC via the control action in the ensuing *RIC Control Request* message from the RIC. + +#### 7.5.8.3 INSERT Service *RIC Indication Header* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Header Format 2* IE (9.2.1.3.2). The *RIC Indication Header* IE has the UE ID, the *Insert* Service Style ID and the corresponding *Insert* Indication ID. + +#### 7.5.8.4 INSERT Service *RIC Indication Message* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Message Format 5* IE (9.2.1.4.5). The *RIC Indication Message* IE includes a sequence of associated RAN parameters for which the E2 node seeks the near-RT RIC to accept/deny the request raised by the E2 node or accordingly set the values for the associated RAN parameters, via the control action in the ensuing *RIC Control Request* IE. + +#### 7.5.8.5 INSERT Service *RIC Call Process ID* IE contents + +This **INSERT** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +### 7.5.9 INSERT Service Style 255: Multiple Actions Control Request + +#### 7.5.9.1 INSERT Service Style description + +This **INSERT** Service style provides a mechanism which contains multiple Insert Indication actions of the selected fundamental level INSERT Service style(s), in order to initiate request to the Near-RT RIC for controlling multiple actions of the supporting functionalities related to the corresponding fundamental level CONTROL Service style(s). If at least one of the embedded Insert Indications is not admitted by E2 node, then the E2 node shall declare the INSERT Action as failed. + +#### 7.5.9.2 INSERT Service *RIC Action Definition* IE contents + +This **INSERT** Service style uses the *E2SM-RC Action Definition Format 4* IE (9.2.1.2.4). + +For each Insert Indication action, the corresponding *Insert Indication ID* IE and the associated RAN parameters follow the definitions of the selected fundamental level INSERT Service style indicated by the *Requested Insert Style* IE. + +#### 7.5.9.3 INSERT Service *RIC Indication Header* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Header Format 3* IE (9.2.1.3.3). + +The *RIC Indication Header* IE may contain the *UE ID* IE, to indicate to the Near-RT RIC that this INSERT indication is only for that specific UE. + +#### 7.5.9.4 INSERT Service *RIC Indication Message* IE contents + +This **INSERT** Service style uses *E2SM-RC Indication Message Format 6* IE (9.2.1.4.6). + +For each Insert Indication action, the corresponding *Insert Indication ID* IE and the associated RAN parameters follow the definitions of the selected fundamental level INSERT Service style indicated by the *Indicated Insert Style* IE. + +#### 7.5.9.5 INSERT Service *RIC Call Process ID* IE contents + +This **INSERT** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +## 7.6 Supported RIC CONTROL Services + +### 7.6.1 CONTROL Service Style Types + +| RIC Style Type | Style Name | Style Description | +|----------------|-----------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Radio Bearer control | Used to modify the configuration the Radio Bearer Control (RBC) related parameters and/or behaviours at the E2 Node for a specific UE or a UE group.<br>Belongs to Fundamental level CONTROL Services. | +| 2 | Radio resource allocation control | Used to modify the configuration the Radio Resource Allocation control related parameters and/or behaviours at the E2 Node for a specific E2 Node, cell, slice, UE and/or QoS<br>Belongs to Fundamental level CONTROL Services. | +| 3 | Connected mode mobility control | Used to initiate a connected mode mobility procedure (Handover or Conditional Handover), optionally with Dual Active Protocol Stack (DAPS), for a specific UE towards either a target cell (for HO) or a list of candidate cells (for CHO)<br>Belongs to Fundamental level CONTROL Services. | +| 4 | Radio access control | Used to modify Radio access related functions used to control UE access to cells<br>Belongs to Fundamental level CONTROL Services. | +| 5 | Dual connectivity (DC) control | Used to initiate Dual connectivity (DC) mechanisms<br>Belongs to Fundamental level CONTROL Services. | +| 6 | Carrier Aggregation (CA) control | Used to initiate Carrier Aggregation (CA) mechanisms<br>Belongs to Fundamental level CONTROL Services. | +| 7 | Idle mode mobility control | Used to modify Idle mode mobility related functions used to control UE reselection of cells<br>Belongs to Fundamental level CONTROL Services. | +| 8 | UE identification, information and assignment | Used for <i>Explicit UE list</i> assignment, UE information report generation and to complete UE identification. These services are used to support other RIC services.<br>Belongs to Fundamental level CONTROL Services. | +| 9 | Measurement Reporting Configuration control | Used to control the measurement report configuration for a given UE or a group of UEs. | +| 10 | Beamforming Configuration control | Used to control beamforming configuration for a specific UE. | +| 255 | Multiple Actions Control | Used for multiple actions of the selected fundamental level CONTROL Service style(s).<br>Belongs to integrated level CONTROL Services. | + +Each of the Control Service styles 1-10 listed above points to adopt the following common features: + +- Control Action ID: The index ID for the individual control action under a given Control Service style. +- Control Action Name: Indicates the functionality of the E2 node which is controlled by Near-RT RIC +- Control Action Description: Describes the control action and functionality of the receiving E2 Node. +- Associated RAN parameters: Identifies the RAN parameters to be controlled by Near-RT RIC pertaining to the given control action and used in the optional RIC Control Outcome to carry information. + +The Control Service style 255 supports multiple parallel actions configured per *RIC Control Request* message by reusing the control actions and the associated RAN parameters defined in the selected fundamental level Control Service style(s). + +The details of the individual Control Service styles are provided in subsequent sections. + +The CONTROL Service supports UE-specific control actions and UE group-specific control actions. In the case of a UE group-based control action, the control action is defined for a group of UEs, and the individual entities of each UE (such as DRBs, QoS flows, etc.) in the group that match the entity filter condition, shall be subject to the control action. + +### 7.6.2 CONTROL Service Style 1: Radio Bearer Control + +#### 7.6.2.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to initiate or resume a radio bearer control related process using the *RIC Control Message* IE and associated *RIC Control Header* IE and the optional *RIC Call Process ID* IE used when resuming a call process following a previous INSERT service. The corresponding INSERT service is service style 1 covered in Clause 7.5.2. + +Applications of this service include: + +- DRB QoS Modification, to tune DRB level QoS related parameters to meet the QoS optimization targets. +- QoS Flow (re)mapping, to adjust the mapping relationship between QoS flows and DRBs. +- Logical channel (re)configuration +- Radio Bearer Admission Control, to configure DRB admission control such as reject or release may be applied +- Split bearer and PDCP duplication control + +The supported RAN control actions and the corresponding RAN parameters are as follows. + +| Control Action ID | Control Action Name | Control Action description | Is UE group-based control action allowed | Associated RAN Parameters | +|-------------------|--------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------|---------------------------| +| 1 | DRB QoS Configuration | To control the configuration of the QoS profile of a DRB or a set of DRBs | YES | 8.4.2.1 | +| 2 | QoS flow mapping configuration | To control the multiplexing of QoS flows to a DRB (addition, modification, deletion) | FFS | 8.4.2.2 | +| 3 | Logical channel configuration | To control the LCID configuration of a DRB or a set of DRBs | YES | 8.4.2.3 | +| 4 | Radio admission control | To control radio admission of a UE | FFS | 8.4.2.4 | +| 5 | DRB termination control | To control the change in bearer termination point | FFS | 8.4.2.5 | +| 6 | DRB split ratio control | To control the split ratio of a DRB across its RLC entities | FFS | 8.4.2.6 | +| 7 | PDCP Duplication control | To control activation or de-activation of PDCP duplication for a DRB or a set of DRBs, and control/configure the number of legs or RLC entities for the DRB(s) | YES | 8.4.2.7 | + +#### 7.6.2.2 CONTROL Service *RIC Control Header IE* contents + +This **CONTROL** Service *RIC Control Header IE* has the *UE ID IE*, the *Control Service Style ID*, the *Control Action ID IE* and the *RIC Control Decision IE* that indicates whether the RIC accepts or rejects the INDICATION request from the previous incoming INSERT indication, if any (with matching *RAN Call Process ID IE*), from the E2 node. + +This **CONTROL** style uses *E2SM-RC Control Header Format 1 IE* (9.2.1.6.1). + +For UE group-based CONTROL action, this CONTROL style uses the *E2SM-RC Control Header Format 3 IE* (9.2.1.6.3), where the *RIC Control Header IE* has the *UE Group ID IE* for identifying the UE group, the *UE Group Definition IE* for defining the UE group, along with the *RIC Style Type IE* and the *Control Action ID IE*. + +#### 7.6.2.3 CONTROL Service *RIC Control Message IE* contents + +This **CONTROL** Service *RIC Control Message IE* contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style, controlled by the near-RT RIC along with the values for these parameters, as set by the RIC. + +This **CONTROL** style uses *E2SM-RC Control Message Format 1 IE* (9.2.1.7.1). + +If there is a previous INSERT Indication Request to the RIC, then the corresponding Control Action ID used by the RIC for the ensuing CONTROL Request message is the one that matches the Insert Indication ID, among the ones provided in the table shown in Clause 7.6.2.1. It is to be noted that the control action “Radio admission control” (corresponding to control action ID 4) is used only as a response to an incoming INSERT indication with the corresponding service style and indication request ID and cannot be used asynchronously without a previous INSERT indication. + +For UE group-based CONTROL action, this CONTROL style uses the *E2SM-RC Control Message Format 3 IE* (9.2.1.7.3). The *RIC Control Message IE* includes the list of filter definitions for identifying the relevant RAN entities of the UE group, given by the *Entity Filter Definition IE* in the *List of entity filters IE*, along with the identifier of the entity filter given by the *Entity Filter ID IE*, for which the control action is applicable. The sequence of RAN parameters controlled by the Near-RT RIC for the entities of the UEs in the group, corresponding to each entity filter, is given by the *List of RAN control parameters for the matching entities IE*. + +#### 7.6.2.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE contains identifier used by the Near-RT RIC to allow the RAN Function to match the outgoing **INSERT** Service message with a subsequent incoming **CONTROL** Service message. + +This **CONTROL** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +#### 7.6.2.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a transparent container that is used to carry the outcome of processing the incoming *RIC Control Request* message. However, this does not reflect the outcome of the call processing upon receiving the message. + +This **CONTROL** style uses *E2SM-RC Control Outcome Format 1* IE (9.2.1.8.1). + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter Description | +|------------------|--------------------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | ReceivedTimestamp | OCTET STRING (SIZE(8)) | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [30] containing both seconds and fraction parts. | + +### 7.6.3 CONTROL Service Style 2: Radio Resource Allocation Control + +#### 7.6.3.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to initiate or resume a radio resource allocation control related process using the *RIC Control Message* IE and associated *RIC Control Header* IE and the optional *RIC Call Process ID* IE used when resuming a call process following a previous **INSERT** service. The corresponding **INSERT** service is service style 2 covered in Clause 7.5.3. + +Applications of this service include: + +- Discontinuous Reception (DRX) control +- Scheduling request (SR) control +- Semi-Persistent Scheduling (SPS) control +- Configured Grant control +- Channel State Information (CSI) report configuration control +- Slice level PRB quota +- Sounding Reference Signal (SRS) configuration control +- CSI resource configuration control +- DMRS-Downlink configuration control + +The supported RAN control actions and the corresponding RAN parameters are as follows. + +| Control Action ID | Control Action Name | Control Action description | Associated RAN Parameters | +|-------------------|------------------------------|-----------------------------------------------------------------------------------------|---------------------------| +| 1 | DRX parameter configuration | To control the configuration of DRX parameters | 8.4.3.1 | +| 2 | SR periodicity configuration | To control the configuration of SR periodicity parameters | 8.4.3.2 | +| 3 | SPS parameters configuration | To control the configuration of SPS parameters | 8.4.3.3 | +| 4 | Configured grant control | To control the configuration of uplink grants to the UE | 8.4.3.4 | +| 5 | CSI reports configuration | To control the configuration of CSI reports. | 8.4.3.5 | +| 6 | Slice-level PRB quota | To control the radio resource management policy for slice-specific PRB quota allocation | 8.4.3.6 | +| 7 | DMRS-Downlink configuration | To control the configuration of DMRS for PDSCH | 8.4.3.7 | +| 8 | SRS Configuration | To control the configuration of the SRS transmissions | 8.4.3.8 | +| 9 | CSI Resource Configuration | To control the configuration of the CSI resources | 8.4.3.9 | + +#### 7.6.3.2 CONTROL Service *RIC Control Header* IE contents + +This **CONTROL** Service *RIC Control Header* IE has the *UE ID* IE, the *Control Service Style ID*, the *Control Action ID* IE and the *RIC Control Decision* IE that indicates whether the RIC accepts or rejects the INDICATION request from the previous incoming INSERT indication, if any (with matching *RAN Call Process ID* IE), from the E2 node. + +This **CONTROL** style uses *E2SM-RC Control Header Format 1* IE (9.2.1.6.1). + +#### 7.6.3.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** Service *RIC Control Message* IE contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style, controlled by the near-RT RIC along with the values for these parameters, as set by the RIC. + +This **CONTROL** style uses *E2SM-RC Control Message Format 1* IE (9.2.1.7.1). + +If there is a previous INSERT Indication Request to the RIC, then the corresponding Control Action ID used by the RIC for the ensuing CONTROL Request message is the one that matches the Insert Indication ID, among the ones provided in the table shown in Clause 7.6.3.1. + +#### 7.6.3.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE contains identifier used by the Near-RT RIC to allow the RAN Function to match the outgoing INSERT Service message with a subsequent incoming **CONTROL** Service message. + +This **CONTROL** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +#### 7.6.3.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a transparent container that is used to carry the outcome of processing the incoming *RIC Control Request* message. However, this does not reflect the outcome of the call processing upon receiving the message. + +This **CONTROL** style uses *E2SM-RC Control Outcome Format 1* IE (9.2.1.8.1). + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter Description | +|------------------|--------------------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | ReceivedTimestamp | OCTET STRING (SIZE(8)) | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [30] containing both seconds and fraction parts. | + +### 7.6.4 CONTROL Service Style 3: Connected Mode Mobility Control + +#### 7.6.4.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to initiate or resume a connected mode mobility control related process using the *RIC Control Message* IE and associated *RIC Control Header* IE and the optional *RIC Call Process ID* IE used when resuming a call process following a previous INSERT service. The corresponding INSERT service is service style 3 covered in Clause 7.5.4. + +Applications of this service include: + +- Handover (HO) initiation for a selected UE towards a target cell +- Conditional handover (CHO) initiation for a selected UE towards a list of candidate cell(s) +- Handover (HO) initiation with Dual Active Protocol Stack (DAPS) for a selected UE towards a target cell + +The supported RAN control actions and the corresponding RAN parameters are as follows. + +| Control Action ID | Control Action Name | Control Action description | Associated RAN parameters | +|-------------------|----------------------------------------------------|---------------------------------------------------------------------------------------|---------------------------| +| 1 | Handover Control | To control the handover of the primary cell and subsequent secondary cell reselection | 8.4.4.1 | +| 2 | Conditional Handover Control | To control the conditional handover involving target primary cells | 8.4.4.2 | +| 3 | DAPS (Dual Active Protocol Stack) Handover Control | To control the DAPS handover of the UE between source cell and target cell | 8.4.4.3 | + +#### 7.6.4.2 CONTROL Service *RIC Control Header* IE contents + +This **CONTROL** Service *RIC Control Header* IE has the *UE ID* IE, the *Control Service Style ID*, the *Control Action ID* IE and the *RIC Control Decision* IE that indicates whether the RIC accepts or rejects the INDICATION request from the previous incoming INSERT indication, if any (with matching *RAN Call Process ID* IE), from the E2 node. + +This **CONTROL** style uses *E2SM-RC Control Header Format 1* IE (9.2.1.6.1). + +#### 7.6.4.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** Service *RIC Control Message* IE contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style, controlled by the near-RT RIC along with the values for these parameters, as set by the RIC. + +This **CONTROL** style uses *E2SM-RC Control Message Format 1* IE (9.2.1.7.1). + +If there is a previous INSERT Indication Request to the RIC, then the corresponding Control Action ID used by the RIC for the ensuing CONTROL Request message is the one that matches the Insert Indication ID, among the ones provided in the table shown in Clause 7.6.4.1. + +#### 7.6.4.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE contains identifier used by the Near-RT RIC to allow the RAN Function to match the outgoing **INSERT** Service message with a subsequent incoming **CONTROL** Service message. + +This **CONTROL** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +#### 7.6.4.5 CONTROL Service *RIC Control Outcome* IE content + +This **CONTROL** Service *RIC Control Outcome* IE contains a transparent container that is used to carry the outcome of processing the incoming *RIC Control Request* message. However, this does not reflect the outcome of the call processing upon receiving the message. + +This **CONTROL** style uses *E2SM-RC Control Outcome Format 1* IE (9.2.1.8.1). + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter Description | +|------------------|--------------------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | ReceivedTimestamp | OCTET STRING (SIZE(8)) | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [30] containing both seconds and fraction parts. | + +### 7.6.5 CONTROL Service Style 4: Radio Access Control + +#### 7.6.5.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to initiate or resume a radio access control related process using the *RIC Control Message* IE and associated *RIC Control Header* IE and the optional *RIC Call Process ID* IE used when resuming a call process following a previous INSERT service. The corresponding INSERT service is service style 4 covered in Clause 7.5.5. + +Applications of this service include: + +- RACH back-off +- RRC connection reject +- RRC connection release +- Access barring +- UE admission + +The supported RAN control actions and the corresponding RAN parameters are as follows. + +| Control Action ID | Control Action Name | Control Action Description | Associated RAN Parameters | +|-------------------|--------------------------------|----------------------------------------------------|---------------------------| +| 1 | UE Admission Control | To control UE admission. | 8.4.5.1 | +| 2 | RACH backoff control | To control RACH backoff parameters | 8.4.5.2 | +| 3 | Access barring control | To control access barring configuration parameters | 8.4.5.3 | +| 4 | RRC Connection Release control | To control release of RRC connection of the UE | 8.4.5.4 | +| 5 | RRC Connection Reject control | To reject RRC connection request of the UE | 8.4.5.5 | + +#### 7.6.5.2 CONTROL Service *RIC Control Header* IE contents + +This **CONTROL** Service *RIC Control Header* IE has the *UE ID* IE, the *Control Service Style ID*, the *Control Action ID* IE and the *RIC Control Decision* IE that indicates whether the RIC accepts or rejects the INDICATION request from the previous incoming INSERT indication, if any (with matching *RAN Call Process ID* IE), from the E2 node. + +This **CONTROL** style uses *E2SM-RC Control Header Format 1* IE (9.2.1.6.1). + +#### 7.6.5.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** Service *RIC Control Message* IE contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style, controlled by the near-RT RIC along with the values for these parameters, as set by the RIC. + +This **CONTROL** style uses *E2SM-RC Control Message Format 1* IE (9.2.1.7.1). + +If there is a previous INSERT Indication Request to the RIC, then the corresponding Control Action ID used by the RIC for the ensuing CONTROL Request message is the one that matches the Insert Indication ID, among the ones provided in the table shown in Clause 7.6.5.1. However, the control action “RRC Connection Reject control” (corresponding to control action ID 5) can also be used to handle an incoming INSERT Indication Request corresponding to service style 4 that uses Indication request ID 1 (that corresponds to UE Admission Control Request). It is also to be noted that the control action “UE admission control” (corresponding to control action ID 1) is used only as a response to an incoming INSERT indication with the corresponding service style and indication request ID and cannot be used asynchronously without a previous INSERT indication. + +#### 7.6.5.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE contains identifier used by the Near-RT RIC to allow the RAN Function to match the outgoing INSERT Service message with a subsequent incoming **CONTROL** Service message. + +This **CONTROL** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +#### 7.6.5.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a transparent container that is used to carry the outcome of processing the incoming *RIC Control Request* message. However, this does not reflect the outcome of the call processing upon receiving the message. + +This **CONTROL** style uses *E2SM-RC Control Outcome Format 1* IE (9.2.1.8.1). + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter Description | +|------------------|--------------------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | ReceivedTimestamp | OCTET STRING (SIZE(8)) | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [30] containing both seconds and fraction parts. | + +### 7.6.6 CONTROL Service Style 5: Dual Connectivity Control + +#### 7.6.6.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to initiate or resume a dual connectivity control related process using the *RIC Control Message* IE and associated *RIC Control Header* IE and the optional *RIC Call Process ID* IE used when resuming a call process following a previous INSERT service. The corresponding INSERT service is service style 5 covered in Clause 7.5.6. + +Applications of this service include: + +- Dual connectivity (EN-DC, MR-DC or NR-NR DC) initiation for a selected UE towards a target secondary cell (PScell) +- Secondary cell change for a selected UE towards a target secondary cell (PScell) +- Dual connectivity (EN-DC, MR-DC or NR-NR DC) modification for a selected UE +- Dual connectivity (EN-DC, MR-DC or NR-NR DC) release initiation for a selected UE +- Change of bearer termination point (MN or SN) and/or bearer types for a selected UE + +The supported RAN control actions and the corresponding RAN parameters are as follows. + +| Control Action ID | Control Action Name | Control Action Description | Associated RAN parameters | +|-------------------|----------------------------------------------------|---------------------------------------------------------------------------------------|---------------------------| +| 1 | DC Secondary Node Addition Control | To control secondary node addition for dual connectivity | 8.4.6.1 | +| 2 | DC Secondary Node Modification and release Control | To control modification and release of secondary node for DC | 8.4.6.2 | +| 3 | DC PSCell Change control | To control PSCell change of a UE within a secondary node or to another secondary node | 8.4.6.3 | +| 4 | DC Secondary Node Change Control | To control changing the secondary node of a UE for DC | 8.4.6.4 | + +#### 7.6.6.2 CONTROL Service *RIC Control Header* IE contents + +This **CONTROL** Service *RIC Control Header* IE has the *UE ID* IE, the *Control Service Style ID*, the *Control Action ID* IE and the *RIC Control Decision* IE that indicates whether the RIC accepts or rejects the INDICATION request from the previous incoming INSERT indication, if any (with matching *RAN Call Process ID* IE), from the E2 node. + +This **CONTROL** style uses *E2SM-RC Control Header Format 1* IE (9.2.1.6.1). + +#### 7.6.6.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** Service *RIC Control Message* IE contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style, controlled by the near-RT RIC along with the values for these parameters, as set by the RIC. + +This **CONTROL** style uses *E2SM-RC Control Message Format 1* IE (9.2.1.7.1). + +If there is a previous INSERT Indication Request to the RIC, then the corresponding Control Action ID used by the RIC for the ensuing CONTROL Request message is the one that matches the Insert Indication ID, among the ones provided in the table shown in Clause 7.6.6.1. + +#### 7.6.6.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE contains identifier used by the Near-RT RIC to allow the RAN Function to match the outgoing **INSERT** Service message with a subsequent incoming **CONTROL** Service message. + +This **CONTROL** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +#### 7.6.6.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a transparent container that is used to carry the outcome of processing the incoming *RIC Control Request* message. However, this does not reflect the outcome of the call processing upon receiving the message. + +This **CONTROL** style uses *E2SM-RC Control Outcome Format 1* IE (9.2.1.8.1). + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter Description | +|------------------|--------------------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | ReceivedTimestamp | OCTET STRING (SIZE(8)) | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [30] containing both seconds and fraction parts. | + +### 7.6.7 CONTROL Service Style 6: Carrier Aggregation Control + +#### 7.6.7.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to initiate or resume a carrier aggregation control related process using the *RIC Control Message* IE and associated *RIC Control Header* IE and the optional *RIC Call Process ID* IE used when resuming a call process following a previous INSERT service. The corresponding INSERT service is service style 6 covered in Clause 7.5.7. + +Applications of this service include: + +- Carrier Aggregation (CA) initiation for a selected UE towards a target secondary cell or cells +- Secondary cell change for a selected UE towards a target secondary cell or cells +- Carrier Aggregation (CA) modification for a selected UE +- Carrier Aggregation (CA) release initiation for a selected UE + +The supported RAN control actions and the corresponding RAN parameters are as follows. + +| Control Action ID | Control Action Name | Control Action Description | Associated RAN parameters | +|-------------------|----------------------------------------|-----------------------------------------------------------------|---------------------------| +| 1 | CA Secondary Cell Addition Control | To control secondary cell addition for a UE | 8.4.7.1 | +| 2 | CA Secondary Cell Modification Control | To control modification and release of secondary cells for a UE | 8.4.7.2 | + +#### 7.6.7.2 CONTROL Service *RIC Control Header* IE contents + +This **CONTROL** Service *RIC Control Header* IE has the *UE ID* IE, the *Control Service Style ID*, the *Control Action ID* IE and the *RIC Control Decision* IE that indicates whether the RIC accepts or rejects the INDICATION request from the previous incoming INSERT indication, if any (with matching *RAN Call Process ID* IE), from the E2 node. + +This **CONTROL** style uses *E2SM-RC Control Header Format 1* IE (9.2.1.6.1). + +#### 7.6.7.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** Service *RIC Control Message* IE contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style, controlled by the near-RT RIC along with the values for these parameters, as set by the RIC. + +This **CONTROL** style uses *E2SM-RC Control Message Format 1* IE (9.2.1.7.1). + +If there is a previous INSERT Indication Request to the RIC, then the corresponding Control Action ID used by the RIC for the ensuing CONTROL Request message is the one that matches the Insert Indication ID, among the ones provided in the table shown in Clause 7.6.7.1. + +#### 7.6.7.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE contains identifier used by the Near-RT RIC to allow the RAN Function to match the outgoing **INSERT** Service message with a subsequent incoming **CONTROL** Service message. + +This **CONTROL** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +#### 7.6.7.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a transparent container that is used to carry the outcome of processing the incoming *RIC Control Request* message. However, this does not reflect the outcome of the call processing upon receiving the message. + +This **CONTROL** style uses *E2SM-RC Control Outcome Format 1* IE (9.2.1.8.1). + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter Description | +|------------------|--------------------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | ReceivedTimestamp | OCTET STRING (SIZE(8)) | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [30] containing both seconds and fraction parts. | + +### 7.6.8 CONTROL Service Style 7: Idle Mode Mobility Control + +#### 7.6.8.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to initiate or resume a idle mode mobility control related process using the *RIC Control Message* IE and associated *RIC Control Header* IE and the optional *RIC Call Process ID* IE used when resuming a call process following a previous INSERT service. The corresponding INSERT service is service style 6 covered in Clause 7.5.7. + +Applications of this service include: + +- Intra-frequency, inter-frequency, inter-RAT cell reselection priority +- Idle timers + +The supported RAN control actions and the corresponding RAN parameters are as follows. + +| Control Action ID | Control Action Name | Control Action Description | Associated RAN parameters | +|-------------------|------------------------------------|-----------------------------------------------------------------------------|---------------------------| +| 1 | Cell re-selection priority control | To assign cell re-selection priorities for a UE during idle mode (RRC_IDLE) | 8.4.8.1 | + +#### 7.6.8.2 CONTROL Service *RIC Control Header* IE contents + +This **CONTROL** Service *RIC Control Header* IE has the *UE ID* IE, the *Control Service Style ID*, the *Control Action ID* IE and the *RIC Control Decision* IE that indicates whether the RIC accepts or rejects the INDICATION request from the previous incoming INSERT indication, if any (with matching *RAN Call Process ID* IE), from the E2 node. + +This **CONTROL** style uses *E2SM-RC Control Header Format 1* IE (9.2.1.6.1). + +#### 7.6.8.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** Service *RIC Control Message* IE contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style, controlled by the near-RT RIC along with the values for these parameters, as set by the RIC. + +This **CONTROL** style uses *E2SM-RC Control Message Format 1* IE (9.2.1.7.1) + +If there is a previous INSERT Indication Request to the RIC, then the corresponding Control Action ID used by the RIC for the ensuing CONTROL Request message is the one that matches the Insert Indication ID, among the ones provided in the table shown in Clause 7.6.8.1. + +#### 7.6.8.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE contains identifier used by the Near-RT RIC to allow the RAN Function to match the outgoing INSERT Service message with a subsequent incoming **CONTROL** Service message. + +This **CONTROL** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +#### 7.6.8.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a transparent container that is used to carry the outcome of processing the incoming *RIC Control Request* message. However, this does not reflect the outcome of the call processing upon receiving the message. + +This **CONTROL** style uses *E2SM-RC Control Outcome Format 1* IE (9.2.1.8.1). + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter Description | +|------------------|--------------------|------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | ReceivedTimestamp | OCTET STRING (SIZE(8)) | <p>Time RIC Control Request message received by RAN Function over E2 interface.</p> <p>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [30] containing both seconds and fraction parts.</p> | + +### 7.6.9 CONTROL Service Style 8: UE information and assignment + +#### 7.6.9.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to both directly and indirectly monitor and control UE information and to add or remove explicit UE assignments to Explicit UE lists. + +Applications of this service include: + +- UE to Explicit UE list assignment command: Used to Add or Remove the nominated UE to the *Explicit UE list* name, also used to request list of supported *Explicit UE list* +- UE information request: Used to obtain UE information including list of *Explicit UE List* assignments +- UE identification request: Used to complete UE identification with *Partial UE ID* carried in *RIC Control Header IE* + +The supported RAN control actions and the corresponding RAN parameters are as follows. + +| Control Action ID | Control Action Name | Control Action Description | RAN Parameter assignment | +|-------------------|-------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------|--------------------------| +| 1 | UE to Explicit UE list assignment command | - To modify (add, remove, change) the assignment of a target UE to an Explicit UE list and send list of supported <i>Explicit UE list</i> | 8.4.9.1 | +| 2 | UE information request | - To provide information on a UE (including list of assigned Explicit UE List) | 8.4.9.2 | +| 3 | UE identification request | - To complete UE identification about a target UE | 8.4.9.3 | + +#### 7.6.9.2 CONTROL Service *RIC Control Header IE* contents + +This **CONTROL** Service *RIC Control Header IE* contains the *UE ID IE*, *RIC Style Type IE* and *Control Action ID IE*. There is no previous INSERT Indication request from the E2 node for this service style. + +Note that for RIC Action ID =1 "UE to Explicit UE list assignment command", the *UE ID IE* in the *RIC Control Header IE* shall be ignored when Assignment command=3 "Send list of supported Explicit UE list" (see clause 8.4.9.1). + +This **CONTROL** style uses: + +- For the case of Control Action ID =1 "UE to Explicit UE list assignment command" and Control Action ID =2 "UE information request", *E2SM-RC Control Header Format 1 IE* (9.2.1.6.1) to be used to identify a specific UE. +- For the case of Control Action 3 "UE identification request", *E2SM-RC Control Header Format 4 IE* (9.2.1.6.4) to be used to identify one or more UE matching a Partial UE ID. + +#### 7.6.9.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** Service *RIC Control Message* IE contains a list of RAN Parameters used to support the information list of Control actions shown in Clause 7.6.9.1. + +This **CONTROL** style uses: + +- For the case of Control Action = 1 "UE to Explicit UE list assignment command", *E2SM-RC Control Message Format 1 IE* (9.2.1.7.1), to be used to carry a sequence of RAN Parameters with values. +- For the case of Control Action = 2 "UE information request", *E2SM-RC Control Message Format 4 IE* (9.2.1.7.4), to be used to carry of sequence of RAN Parameter Definitions. +- For the case of Control Action = 3 "UE identification request", *E2SM-RC Control Message Format 5 IE* (9.2.1.7.5) containing no information, to be used to satisfy E2AP requirements for a mandatory *RIC Control Message* IE. + +#### 7.6.9.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE is not supported for this **CONTROL** service style. + +#### 7.6.9.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE contains a list of RAN Parameters and is used to carry information concerning the outcome of executing the RIC Control Request. + +| Control Action ID | Control Action Name | Expected information | RAN Parameter assignment | +|-------------------|-------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------| +| 1 | UE to Explicit UE list assignment command | Success case:<br>- not used (for add/remove/change assignment commands)<br>- list of supported Explicit UE list (for assignment command =3)<br><br>Failure case:<br>- Failure Cause | 8.4.9.1 | +| 2 | UE Information request | Success case: Requested UE information<br><br>Failure case: UE not known error | 8.4.9.2 | +| 3 | UE identification request | Success case: List of UE ID matching partial UE ID<br><br>Failure case: UE not known error | 8.4.9.3 | + +This **CONTROL** style uses *E2SM-RC Control Outcome Format 3 IE* (9.2.1.8.3). + +### 7.6.10 CONTROL Service Style 255: Multiple Actions Control + +#### 7.6.10.1 CONTROL Service Style description + +This **CONTROL** Service style provides a mechanism to initiate multiple control actions of the selected fundamental level **CONTROL** Service style(s) that should be processed in an integrated manner by the E2 Node, i.e. the RIC Control procedure is considered failed if at least one of the indicated control actions is unsuccessfully executed, and RIC **CONTROL FAILURE** message shall be sent containing the RIC Control Outcome for failed Control Action. + +#### 7.6.10.2 CONTROL Service *RIC Control Header* IE contents + +This **CONTROL** style uses *E2SM-RC Control Header Format 2 IE* (9.2.1.6.2). + +The *RIC Indication Header* IE may contain the *UE ID* IE to indicate to the E2 Node that this control request is only for that specific UE. The *RIC Control Decision* IE may also be included to indicate to the E2 Node whether the Near-RT RIC accepts or rejects the INDICATION request from the previous incoming INSERT indication, if any (with matching *RAN Call Process ID* IE), from the E2 node. + +#### 7.6.10.3 CONTROL Service *RIC Control Message* IE contents + +This **CONTROL** style uses *E2SM-RC Control Message Format 2* IE (9.2.1.7.2). + +The RAN control actions and the corresponding RAN parameters under a fundamental level Control Service style contained in the *RIC Control Message* IE follows the definitions of the indicated Control Service style. + +If this control request is sent as a response to a previous INSERT indication from the E2 node, then the *Control Action ID* IE in the *RIC Control Message* IE is set in accordance with the triggered Insert Indication ID. + +#### 7.6.10.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service style uses *E2SM-RC Call Process ID Format 1* IE (9.2.1.5.1). + +The optional *RIC Call Process ID* IE is used when resuming a call process following a previous INSERT indication from the E2 Node. + +#### 7.6.10.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** style uses *E2SM-RC Control Outcome Format 2* IE (9.2.1.8.2). + +For each control action indicated by the *Control Action ID* IE, the associated RAN parameters are used to carry the corresponding processing outcome. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter Description | +|------------------|--------------------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | ReceivedTimestamp | OCTET STRING (SIZE(8)) | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [30] containing both seconds and fraction parts. | +| 2 | Cause | OCTET STRING | FFS | + +### 7.6.11 CONTROL Service Style 9: Measurement Reporting Configuration Control + +#### 7.6.11.1 CONTROL Service Style description + +This CONTROL Service style provides a mechanism to add, modify or delete measurement report configuration for the UE to the network using the *RIC Control Message* IE and the *RIC Control Header* IE. + +Applications of this service include: + +- Add configuration of measurement objects, reporting objects, measurement gaps, etc. for UE reporting, pertaining to a given UE or a group of UEs +- Modify configuration of measurement objects, reporting objects, measurement gaps, etc. for UE reporting, pertaining to a given UE or a group of UEs +- Delete configuration of measurement objects, reporting objects, measurement gaps, etc. for UE reporting, pertaining to a given UE or a group of UEs + +The supported RAN control actions and the corresponding RAN parameters are as follows: + +| Control Action ID | Control Action Name | Control Action description | Is UE group-based control action allowed | Associated RAN Parameters | +|-------------------|-------------------------|----------------------------------------------------------------------------------------------------------------------|------------------------------------------|---------------------------| +| 1 | Add MR Configuration | To add configuration of measurement objects, reporting objects, measurement gaps for a given UE or a group of UEs | YES | 8.4.10.1 | +| 2 | Modify MR Configuration | To modify configuration of measurement objects, reporting objects, measurement gaps for a given UE or a group of UEs | YES | 8.4.10.2 | +| 3 | Delete MR Configuration | To delete configuration of measurement objects, reporting objects, measurement gaps for a given UE or a group of UEs | YES | 8.4.10.3 | + +### 7.6.11.2 CONTROL Service *RIC Control Header* IE contents + +The CONTROL Service *RIC Control Header* IE has the *UE ID* IE, the *Control Service Style ID* IE, the *Control Action ID* IE. The *RIC Control Decision* IE for this service style is currently not supported for this control service style. + +This CONTROL style uses *E2SM-RC Control Header Format 1* IE (9.2.1.6.1). + +For UE group-based CONTROL action, this CONTROL style uses the *E2SM-RC Control Header Format 3* IE (9.2.1.6.3), where the *RIC Control Header* IE has the *UE Group ID* IE for identifying the UE group, the *UE Group Definition* IE for defining the UE group in terms of one or more associated RAN parameters, along with the *RIC Style Type* IE and the *Control Action ID* IE. + +### 7.6.11.3 CONTROL Service *RIC Control Message* IE contents + +This CONTROL Service *RIC Control Message* IE contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style. + +This CONTROL style uses *E2SM-RC Control Message Format 1* IE (9.2.1.7.1). + +For UE group-based CONTROL action, this CONTROL style uses the *E2SM-RC Control Message Format 3* IE (9.2.1.7.3). The *RIC Control Message* IE may optionally include the list of filter definitions for identifying the relevant RAN entities of the UE group, given by the *Entity Filter Definition* IE in the *List of entity filters* IE, along with the identifier of the entity filter given by the *Entity Filter ID* IE, for which the control action is applicable. The sequence of RAN parameters controlled by the Near-RT RIC for the entities of the UEs in the group, corresponding to each entity filter, is given by the *List of RAN control parameters for the matching entities* IE. + +If the *UE Group Definition* IE and the *List of entity filters* IE do not point to one or more cells, then the control action is applied to the relevant groups of UEs, as identified by the *UE Group Definition* IE, across all cells within the E2 node. + +### 7.6.11.4 CONTROL Service *RIC Call Process ID* IE contents + +This CONTROL Service *RIC Call Process ID* IE is currently not supported for this CONTROL service style. + +### 7.6.11.5 CONTROL Service *RIC Control Outcome* IE contents + +This CONTROL Service *RIC Control Outcome* IE is used to carry the outcome of processing the incoming *RIC Control Request* message. The corresponding RAN parameters supported for *RIC Control Outcome* IE are given in Clause 8.4.10.4. + +This CONTROL style uses *E2SM-RC Control Outcome Format 3* IE (9.2.1.8.3). + +If the control action is a UE group-based control action, then the CONTROL style uses the *E2SM-RC Control Outcome Format 1* IE and includes the RAN parameters shown in table 7.6.11.5-1 in the *RIC Control Outcome* IE. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter Description | +|------------------|--------------------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | ReceivedTimestamp | OCTET STRING (SIZE(8)) | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [30] containing both seconds and fraction parts. | + +## 7.6.12 CONTROL Service Style 10: Beamforming Configuration Control + +### 7.6.12.1 CONTROL Service Style description + +This CONTROL Service style provides a mechanism to add, modify or delete beamforming configuration for a UE using the *RIC Control Message IE* and the *RIC Control Header IE*. + +Applications of this service include: + +- Configure, reconfigure, or release Non-GoB beamforming mode [32] for a UE +- Configure, reconfigure, or release GoB beamforming configurations (e.g., PMIs, P2-beam indexes etc.) [32] for a UE + +The supported RAN control actions and the corresponding RAN parameters are as follows: + +| Control Action ID | Control Action Name | Control Action description | Associated RAN Parameters | +|-------------------|-------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| +| 1 | Non-GoB BF Mode Configuration | To configure, reconfigure, or release Non-GoB beamforming mode [32] for a UE. The (re)configured Non-GoB BF mode index is the best inferred Non-GoB BF mode index by AI/ML to be used for the UE by the scheduler in E2 Node, for which could be configured separately for the case of Single User- and/or Multi-user MIMO [32]. | 8.4.11.1 | +| 2 | GoB BF Configuration | To configure, reconfigure, or release GoB beamforming configuration (e.g., PMIs, P2-beam indexes etc.) for a UE [32]. The (re)configured GoB BF configuration is the best inferred GoB BF configuration by AI/ML to be used for the UE by the scheduler in E2 Node [32]. | 8.4.11.2 | + +### 7.6.12.2 CONTROL Service *RIC Control Header IE* contents + +The CONTROL Service *RIC Control Header IE* has the *UE ID IE*, the *Control Service Style ID IE*, the *Control Action ID IE*. The *RIC Control Decision IE* for this service style is currently not supported for this control service style. + +This CONTROL style uses *E2SM-RC Control Header Format 1 IE* (9.2.1.6.1). + +### 7.6.12.3 CONTROL Service *RIC Control Message IE* contents + +This CONTROL Service *RIC Control Message IE* contains the sequence of RAN parameters, associated with a given Control Action within this Control Service style. + +The corresponding RAN parameters supported for *RIC Control Message IE* are given in Clause 8.4.11. + +This CONTROL style uses *E2SM-RC Control Message Format 1 IE* (9.2.1.7.1). + +## 7.6.12.4 CONTROL Service *RIC Call Process ID* IE contents + +This **CONTROL** Service *RIC Call Process ID* IE is currently not supported for this CONTROL service style. + +## 7.6.12.5 CONTROL Service *RIC Control Outcome* IE contents + +This **CONTROL** Service *RIC Control Outcome* IE is currently not supported for this CONTROL service style. + +# 7.7 Supported RIC POLICY Services + +## 7.7.1 POLICY Service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|--------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Radio Bearer Policy | Used to define a policy for modifying the behaviour of Radio Bearer Control (RBC) of call processes for a specific RAN UE Group based on cell, slice, UE list and/or QoS | +| 2 | Radio resource allocation Policy | Used to define a policy for modifying the behaviour of Radio Resource Allocation control of call processes for a specific RAN UE Group based on cell, slice, UE list and/or QoS | +| 3 | Connected mode mobility Policy | Used to define a policy for modifying the behaviour of connected mode mobility procedure (Handover or Conditional Handover), optionally with Dual Active Protocol Stack (DAPS), call processes for a specific RAN UE Group based on cell, slice, UE list and/or QoS | +| 4 | Radio access Policy | Used to define a policy for modifying the behaviour of radio access control processes | +| 5 | Dual connectivity (DC) Policy | Used to define a policy for modifying the behaviour of dual connectivity (DC) call processes for a specific RAN UE Group based on cell, slice, UE list and/or QoS | +| 6 | Carrier Aggregation (CA) Policy | Used to define a policy for modifying the behaviour of carrier aggregation (CA) call processes for a specific RAN UE Group based on cell, slice, UE list and/or QoS | +| 7 | Idle mode mobility Policy | Used to define a policy for modifying the behaviour of idle mode configuration call processes for a specific RAN UE Group based on cell, slice and/or UE list. | +| 8 | Measurement Reporting Configuration Policy | Used to define a policy for configuration of measurement objects and reporting objects | +| 9 | Beamforming Configuration Policy | Used to define a policy for beamforming configuration for a specific UE | + +Each of the POLICY Service Styles 1-8 listed above are supported using the following common features: + +- **Event Trigger:** POLICY service is initiated by either Event Trigger style 1: Message Event or Event Trigger style 2: Call process breakpoint. +- **Action ID:** The index ID for the individual action under a given POLICY Service style. +- **Action Name:** Indicates the functionality of the E2 node which is controlled by Near-RT RIC +- **Action Description:** Describes the action and functionality of the receiving E2 Node. +- **Associated RAN parameters:** Identifies the RAN parameters to be controlled by Near-RT RIC pertaining to the given Policy action, used to define Policy Condition and RAN Imperative Policy. + +All **POLICY** Service styles use *E2SM-RC Action Definition Format 2* IE (9.2.1.2.2) which provides the policy conditions and corresponding Policy Action. All of these factors are defined as a sequence of RAN Parameters assigned according to a given Policy Style and Policy Action where: + +- *Policy Action ID* is a Policy specific identifier of a specific Action for a specific Policy style. +- *Policy Condition* is a Policy specific condition to select a specific *Policy Action*. *Policy Condition* is described in terms of a list of test conditions concerning UE and E2 Node information selection criteria using RAN + +Parameters defined with a *Conditional Criteria Definition*. Default RAN behavior is to be applied to any UE when none of the Policy conditions are met. + +- *Policy Action* is encoded in terms of a list of specific RAN Parameters and shall be applied to any UE that meets a specific Policy Condition. Policy Action may contain optional Policy Decision to indicate acceptance or rejection of a RRM function when the Policy Conditions are met. +- *Policy Condition ID* is a *Policy Condition* specific identifier. May be used by E2 Node to identify specific *Policy Condition* item in the list of Policy Conditions defined in the *E2SM-RC Action Definition Format 2 IE*. When present, for the case of Offset based policy, the Policy conditions list in the *E2SM-RC Action Definition Format 2 IE* shall be assessed in order of the *Policy Condition ID IE*. + +The details of the individual POLICY Service Styles and specific Policy Actions are provided in subsequent sections. + +## 7.7.2 POLICY Service Style 1: Radio Bearer Policy + +### 7.7.2.1 POLICY Service Style description + +This **POLICY** Service style provides an Imperative Policy to control execution of a radio bearer control related process. + +Applications of this service include: + +- DRB QoS Modification, to tune DRB level QoS related parameters to meet the QoS optimization targets. +- QoS Flow mapping, to adjust the mapping relationship between QoS flows and DRBs. +- Logical channel configuration +- Radio Bearer Admission, to guide DRB admission control algorithms for admission and/or rejection of DRB requests +- DRB termination +- DRB Split bearer +- PDCP duplication control + +### 7.7.2.2 POLICY Service *RIC Action Definition IE* contents + +This **POLICY** Service style uses *E2SM-RC Action Definition Format 2 IE* (9.2.1.2.2) using the approach described in Clause 7.7.1. + +The supported Policy Actions for this Policy style are as follows: + +| Policy Action ID | Policy Action Name | Policy Action Description | Associated RAN Parameters | +|------------------|------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| +| 1 | Policy for DRB QoS Configuration | To setup a policy for the configuration of DRB QoS profile | 8.5.2.1 | +| 2 | Policy for QoS flow mapping configuration | To setup a policy for the multiplexing of QoS flows to a DRB (addition, modification, deletion) | 8.5.2.2 | +| 3 | Policy for Logical channel (re-) configuration | To setup a policy for the LCID configuration of a DRB | 8.5.2.3 | +| 4 | Policy for Radio admission control | To setup a policy for radio admission control of a UE | 8.5.2.4 | +| 5 | Policy for DRB termination control | To setup a policy for change in the bearer termination point | 8.5.2.5 | +| 6 | Policy for DRB split ratio control | To setup a policy for controlling the split ratio of a DRB across its RLC entities | 8.5.2.6 | +| 7 | Policy for PDCP Duplication control | To setup a policy for controlling the activation or de-activation of PDCP duplication for a DRB and control/configure the number of legs or RLC entities for the DRB | 8.5.2.7 | + +## 7.7.3 POLICY Service Style 2: Radio Resource Allocation Policy + +### 7.7.3.1 POLICY Service Style description + +This **POLICY** Service style provides an Imperative Policy to control execution of a radio resource allocation control related process. + +Applications of this service include: + +- Discontinuous Reception (DRX) control +- Scheduling request (SR) control +- Semi-Persistent Scheduling (SPS) control +- Configured grant +- Channel Quality Indicator (CQI) table +- Slice level PRB quota + +### 7.7.3.2 POLICY Service *RIC Action Definition* IE contents + +This **POLICY** Service style uses *E2SM-RC Action Definition Format 2* IE (9.2.1.2.2) using the approach described in Clause 7.7.1. + +The supported Policy Actions for this Policy style are as follows: + +| Policy Action ID | Policy Action Name | Policy Action description | Associated RAN Parameters | +|------------------|-----------------------------------------|----------------------------------------------------------------------|---------------------------| +| 1 | Policy for DRX parameter configuration | To setup a policy for the configuration of DRX parameters | 8.5.3.1 | +| 2 | Policy for SR periodicity configuration | To setup a policy for the configuration of SR periodicity parameters | 8.5.3.2 | +| 3 | Policy for SPS parameters configuration | To setup a policy for the configuration of SPS parameters | 8.5.3.3 | +| 4 | Policy for Configured grant control | To setup a policy for the configuration of uplink grants to the UE | 8.5.3.4 | +| 5 | Policy for CQI table configuration | To setup a policy for the configuration of CQI table. | 8.5.3.5 | +| 6 | Policy for Slice level PRB quota | To setup a policy for the configuration of slice-level PRB quota | 8.5.3.6 | + +## 7.7.4 POLICY Service Style 3: Connected Mode Mobility Policy + +### 7.7.4.1 POLICY Service Style description + +This **POLICY** Service style provides an Imperative Policy to control execution of a connected mode mobility control related process. + +Applications of this service, for both serving and target RAN nodes, include: + +- Handover (HO) or Conditional handover (CHO) mode selection +- Measurement configuration for handover candidate cell detection (intra-frequency, inter-frequency, inter-RAT) +- Handover decision and target cell selection +- Dual Active Protocol Stack (DAPS) usage + +### 7.7.4.2 POLICY Service *RIC Action Definition* IE contents + +This **POLICY** Service style uses *E2SM-RC Action Definition Format 2* IE (9.2.1.2.2) using the approach described in Clause 7.7.1. + +The supported Policy Actions for this Policy style are as follows: + +| Policy Action ID | Policy Action Name | Policy Action description | Associated RAN parameters | +|------------------|---------------------------------------------------------------|--------------------------------------------------------------------------------------------------|---------------------------| +| 1 | Policy for Handover Control | To setup a policy for the handover of the primary cell and subsequent secondary cell reselection | 8.5.4.1 | +| 2 | Policy for Conditional Handover Control | To setup a policy for the conditional handover involving target primary cells | 8.5.4.2 | +| 3 | Policy for DAPS (Dual Active Protocol Stack) Handover Control | To setup a policy for the DAPS handover of a UE involving source and target cells. | 8.5.4.3 | + +## 7.7.5 POLICY Service Style 4: Radio Access Policy + +### 7.7.5.1 POLICY Service Style description + +This **POLICY** Service style provides an Imperative Policy to control execution of a radio access control related process. + +Applications of this service include: + +- RACH back-off +- RRC connection admission +- RRC connection release +- Access barring +- UE Admission + +### 7.7.5.2 POLICY Service *RIC Action Definition* IE contents + +This **POLICY** Service style uses *E2SM-RC Action Definition Format 2* IE (9.2.1.2.2) using the approach described in Clause 7.7.1. + +The supported Policy Actions for this Policy style are as follows: + +| Policy Action ID | Policy Action Name | Policy Action Description | Associated RAN Parameters | +|------------------|-------------------------------------------|-------------------------------------------------------------------------------------|---------------------------| +| 1 | Policy for UE Admission Control | To setup a policy for controlling UE admission. | 8.5.5.1 | +| 2 | Policy for RACH backoff control | To setup a policy for controlling RACH backoff parameters | 8.5.5.2 | +| 3 | Policy for Access barring control | To setup a policy for controlling access barring configuration parameters | 8.5.5.3 | +| 4 | Policy for RRC Connection Release control | To setup a policy for controlling the release of RRC connection of the UE | 8.5.5.4 | +| 5 | Policy for RRC Connection Reject control | To setup a policy for controlling the rejection of RRC connection request of the UE | 8.5.5.5 | + +## 7.7.6 POLICY Service Style 5: Dual Connectivity (DC) Policy + +### 7.7.6.1 POLICY Service Style description + +This **POLICY** Service style provides an Imperative Policy to control execution of a dual connectivity control related process. + +Applications of this service, for both Master and Secondary nodes, include: + +- DC (EN-DC, MR-DC or NR-NR DC) mode selection +- Measurement configuration for candidate secondary cell detection +- DC initiation decision (M-NG-RAN or MeNB role) +- DC change decision (M-NG-RAN or MeNB role) +- DC addition request acceptance (S-NG-RAN or SgNB role) +- Target secondary cell selection + +- DC release decision +- Change of bearer termination point (MN or SN) and/or bearer types + +### 7.7.6.2 POLICY Service *RIC Action Definition* IE contents + +This **POLICY** Service style uses *E2SM-RC Action Definition Format 2* IE (9.2.1.2.2) using the approach described in Clause 7.7.1. + +The supported Policy Actions for this Policy style are as follows: + +| Policy Action ID | Policy Action Name | Policy Action Description | Associated RAN parameters | +|------------------|---------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------|---------------------------| +| 1 | Policy for DC Secondary Node Addition Control | To setup a policy for controlling secondary node addition for dual connectivity | 8.5.6.1 | +| 2 | Policy for DC Secondary Node Modification and release Control | To setup a policy for controlling modification and release of secondary node for DC | 8.5.6.2 | +| 3 | Policy for DC PSCell Change control | To setup a policy for controlling PSCell change of a UE within a secondary node or to another secondary node | 8.5.6.3 | +| 4 | Policy for DC Secondary Node Change Control | To setup a policy for controlling the change of the secondary node of a UE for DC | 8.5.6.4 | + +## 7.7.7 POLICY Service Style 6: Carrier Aggregation (CA) Policy + +### 7.7.7.1 POLICY Service Style description + +This **POLICY** Service style provides an Imperative Policy to control execution of a carrier aggregation control related process. + +Applications of this service include: + +- Measurement configuration for candidate secondary cell detection +- CA initiation decision +- Target secondary cell selection +- CA release decision + +### 7.7.7.2 POLICY Service *RIC Action Definition* IE contents + +This **POLICY** Service style uses *E2SM-RC Action Definition Format 2* IE (9.2.1.2.2) using the approach described in Clause 7.7.1. + +The supported Policy Actions for this Policy style are as follows: + +| Policy Action ID | Policy Action Name | Policy Action Description | Associated RAN parameters | +|------------------|---------------------------------------------------------------|--------------------------------------------------------------------------------------------|---------------------------| +| 1 | Policy for CA Secondary Cell Addition Control | To setup a policy for controlling secondary cell addition for a UE | 8.5.7.1 | +| 2 | Policy for CA Secondary Cell Modification and Release Control | To setup a policy for controlling the modification and release of secondary cells for a UE | 8.5.7.2 | + +## 7.7.8 POLICY Service Style 7: Idle Mode Mobility Policy + +### 7.7.8.1 POLICY Service Style description + +This **POLICY** Service style provides an Imperative Policy to control execution of a idle mode mobility control related process. + +Applications of this service include: + +- Cell re-selection criteria (intra-frequency, inter-frequency, inter-RAT) +- Inactivity timer + +### 7.7.8.2 POLICY Service RIC Action Definition IE contents + +This **POLICY** Service style uses *E2SM-RC Action Definition Format 2* IE (9.2.1.2.2) using the approach described in Clause 7.7.1. + +The supported Policy Actions for this Policy style are as follows: + +| Policy Action ID | Policy Action Name | Policy Action Description | Associated RAN parameters | +|------------------|-----------------------------------------------|---------------------------------------------------------------------------------------------------|---------------------------| +| 1 | Policy for Cell re-selection priority control | To setup a policy for assigning cell re-selection priorities for a UE during idle mode (RRC_IDLE) | 8.5.8.1 | + +## 7.7.9 POLICY Service Style 8: Measurement Reporting Configuration Policy + +### 7.7.9.1 POLICY Service Style description + +This **POLICY** Service style provides an imperative policy to add, modify or delete measurement report configuration for the UE to the network. + +Applications of this service include: + +- Policy to add configuration of measurement objects, reporting objects, measurement gaps, etc. +- Policy to modify configuration of measurement objects, reporting objects, measurement gaps, etc. +- Policy to delete configuration of measurement objects, reporting objects, measurement gaps, etc. + +### 7.7.9.2 POLICY Service *RIC Action Definition* IE contents + +This POLICY Service style uses *E2SM-RC Action Definition Format 2* IE (9.2.1.2.2) using the approach described in Clause 7.7.1. + +The supported Policy Actions for this Policy style are as follows: + +| Policy Action ID | Policy Action Name | Policy Action description | Associated RAN Parameters | +|------------------|------------------------------------------|-----------------------------------------------------------------------------------------------------------|---------------------------| +| 1 | Policy for MR Configuration addition | To setup a policy for adding configuration of measurement objects, reporting objects, measurement gaps | 8.5.9.1 | +| 2 | Policy for MR Configuration modification | To setup a policy for modifying configuration of measurement objects, reporting objects, measurement gaps | 8.5.9.2 | +| 3 | Delete MR Configuration | To setup a policy for deleting configuration of measurement objects, reporting objects, measurement gaps | 8.5.9.3 | + +## 7.7.10 POLICY Service Style 9: Beamforming Configuration Policy + +### 7.7.10.1 POLICY Service Style description + +This **POLICY** Service style provides an imperative policy to add, modify or delete beamforming configuration for a UE. + +Applications of this service include: + +- Policy to configure, reconfigure, or release Non-GoB beamforming mode [32] for a UE +- Policy to configure, reconfigure, or release GoB beamforming configuration [32] for a UE + +### 7.7.10.2 POLICY Service *RIC Action Definition* IE contents + +This **POLICY** Service style uses *E2SM-RC Action Definition Format 2* IE (9.2.1.2.2) using the approach described in Clause 7.7.1. + +The supported Policy Actions for this Policy style are as follows: + +| Policy Action ID | Policy Action Name | Policy Action Description | Associated RAN parameters | +|------------------|------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------| +| 1 | Policy for Non-GoB BF Mode Configuration | To setup a policy to configure, reconfigure, or release Non-GoB beamforming mode [32] for a UE. This policy action of (re)configuring or releasing Non-GoB BF mode index is applied only when the corresponding policy condition (if configured) is triggered. The (re)configured Non-GoB BF mode index is the best inferred Non-GoB BF mode index by AI/ML to be used for the UE by the scheduler in the E2 Node, for which could be configured separately for the case of Single User- and/or Multi-user MIMO [32]. | 8.5.10.1 | +| 2 | Policy for GoB BF Configuration | To setup a policy to configure, reconfigure, or release GoB beamforming configuration (e.g., PMIs, P2-beam indexes etc.) for a UE [32]. This policy action of (re)configuring or releasing GoB BF configuration is applied only when the corresponding policy condition (if configured) is triggered. The (re)configured GoB BF configuration is the best inferred GoB BF configuration by AI/ML to be used for the UE by the scheduler in the E2 Node [32]. | 8.5.10.2 | + +## 7.8 Supported RIC QUERY Services + +### 7.8.1 QUERY Service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|---------------------------|---------------------------------------------------------------| +| 1 | E2 Node Information Query | Used to request and respond on information related to E2 Node | +| 2 | UE Information Query | Used to request and respond on information related to UE | + +### 7.8.2 QUERY Service Style 1: E2 Node Information Query + +#### 7.8.2.1 QUERY Service Style description + +This **QUERY** Service style is used to request any data related to E2 Node by Near-RT RIC. E2 Node shall use this service style to respond to the requested information from Near-RT RIC. The data related to the following information, can be requested and responded using this service. + +- Cell Configuration related information +- Neighbour Relation related information + +#### 7.8.2.2 QUERY Service *RIC Query Header* IE contents + +This **QUERY** Service style uses the *E2SM-RC Query Header Format 1* IE (9.2.1.9.1). + +#### 7.8.2.3 QUERY Service *RIC Query Definition* IE contents + +The RIC Query Definition for this service style indicates the information type requested by Near-RT RIC. + +The **QUERY** Service style uses the *E2SM-RC Query Definition Format 1* IE (9.2.1.10.1). The supported Parameters for this format are provided in Clause 8.6.1. + +#### 7.8.2.4 QUERY Service *RIC Query Outcome* IE contents + +This **QUERY** Service style uses the *E2SM-RC Query Outcome Format 1* IE (9.2.1.11.1). The mapping of RAN parameters configured in the *RIC Query Definition* IE to the reported IEs in the *E2SM-RC Query Outcome Format 1* IE is provided in the semantics description of the IEs. + +### 7.8.3 QUERY Service Style 2: UE Information Query + +#### 7.8.3.1 QUERY Service Style description + +This **QUERY** Service style is used to request any data related to UE Information by Near-RT RIC. E2 Node shall use this service style to respond to the requested information from Near-RT RIC. The data related to the following information, but not limited to, can be requested and responded using this service. + +- UE Context related information + +The reporting may be per UE based depending on the information requested. + +#### 7.8.3.2 QUERY Service *RIC Query Header* IE contents + +This **QUERY** Service style uses the *E2SM-RC Query Header Format 1* IE (9.2.1.9.1). + +#### 7.8.3.3 QUERY Service *RIC Query Definition* IE contents + +The RIC Query Definition for this service style indicates the information type requested by Near-RT RIC. + +The **QUERY** Service style uses the *E2SM-RC Query Definition Format 1* IE (9.2.1.10.1). The supported Parameters for this format are provided in Clause 8.6.2. + +#### 7.8.3.4 QUERY Service RIC Query Outcome IE contents + +This **QUERY** Service style uses the *E2SM-RC Query Outcome Format 2* IE (9.2.1.11.2). The mapping of RAN parameters configured in the *RIC Query Definition* IE to the reported IEs in the *E2SM-RC Query Outcome Format 2* IE is provided in the semantics description of the IEs. + +## 7.9 Supported RIC Service Styles and E2SM IE Formats + +Table 7.9-1, Table 7.9-2 and Table 7.9.3 provide a summary of the E2SM IE Formats defined to support this E2SM specification. + +**Table 7.9-1: Summary of the E2SM IE Formats defined to support RIC Event Trigger Styles** + +| RIC Event Trigger Style | RIC Event Trigger Definition Format | +|-------------------------|-------------------------------------| +| Style 1 | 1 | +| Style 2 | 2 | +| Style 3 | 3 | +| Style 4 | 4 | + +Table 7.9-2: Summary of the E2SM IE Formats defined to support RIC Service Styles + +| RIC Service Style | Action Definition Format | Indication Header Format | Indication Message Format | Call Process ID Format | Control Header Format | Control Message Format | Control Outcome Format | +|-------------------|--------------------------|--------------------------|---------------------------|------------------------|-----------------------|------------------------|------------------------| +| <b>REPORT</b> | | | | | | | | +| Style 1 | 1 | 1 | 1 | | | | | +| Style 2 | 1 | 1 | 2 | | | | | +| Style 3 | 1 | 1 | 3 | | | | | +| Style 4 | 1 | 1 | 2 | | | | | +| | | | | | | | | +| <b>INSERT</b> | | | | | | | | +| Style 1 | 3 | 2 | 5 | 1 | | | | +| Style 2 | 3 | 2 | 5 | 1 | | | | +| Style 3 | 3 | 2 | 5 | 1 | | | | +| Style 4 | 3 | 2 | 5 | 1 | | | | +| Style 5 | 3 | 2 | 5 | 1 | | | | +| Style 6 | 3 | 2 | 5 | 1 | | | | +| Style 7 | 3 | 2 | 5 | 1 | | | | +| Style 255 | 4 | 3 | 6 | 1 | | | | +| | | | | | | | | +| <b>CONTROL</b> | | | | | | | | +| Style 1 | | | | 1 | 1, 3 | 1, 3 | 1 | +| Style 2 | | | | 1 | 1 | 1 | 1 | +| Style 3 | | | | 1 | 1 | 1 | 1 | +| Style 4 | | | | 1 | 1 | 1 | 1 | +| Style 5 | | | | 1 | 1 | 1 | 1 | +| Style 6 | | | | 1 | 1 | 1 | 1 | +| Style 7 | | | | 1 | 1 | 1 | 1 | +| Style 8 | | | | | 1, 4 | 1, 2, 3 | 3 | +| Style 9 | | | | | 1 | 1 | 3 | +| Style 10 | | | | | 1 | 1 | | +| Style 255 | | | | 1 | 2 | 2 | 2 | +| | | | | | | | | +| <b>POLICY</b> | | | | | | | | +| Style 1 | 2 | | | | | | | +| Style 2 | 2 | | | | | | | +| Style 3 | 2 | | | | | | | +| Style 4 | 2 | | | | | | | +| Style 5 | 2 | | | | | | | +| Style 6 | 2 | | | | | | | +| Style 7 | 2 | | | | | | | +| Style 8 | 2 | | | | | | | +| Style 9 | 2 | | | | | | | +| | | | | | | | | + +Table 7.9-3: Summary of the E2SM IE Formats defined to support RIC Service Styles + +| RIC Service Style | Query Header Format | Query Definition Format | Query Outcome Format | +|-------------------|---------------------|-------------------------|----------------------| +| <b>QUERY</b> | | | | +| Style 1 | 1 | 1 | 1 | +| Style 2 | 1 | 1 | 2 | + +## 8 RAN Parameter assignments + +### 8.0 Approach + +The RAN parameters associated with each RIC service described in Clause 7 are listed here in Clause 8. Each RAN parameter belongs to one of the following value types: + +- **ELEMENT**: a singleton variable, which does not have any other associated RAN parameters. +- **STRUCTURE**: a sequence of RAN parameters, each of which can be either an **ELEMENT** or a **STRUCTURE** or a **LIST** +- **LIST**: a list of **STRUCTURES**, where each **STRUCTURE** is as defined above. The sequence of RAN parameters is the same across all the **STRUCTURES** within the list. + +The corresponding 3GPP standard definitions of these RAN parameters (if available) are referenced in the tables below under the “RAN Parameter Definition” column. These RAN parameters having 3GPP standard definitions are not freshly defined or redefined here. + +Note that only those RAN parameters identified as **ELEMENT** are subject to test conditions by the RIC in the “Event Trigger Definition”. + +Any RAN parameter within a **STRUCTURE** or **LIST** shall not be referenced individually. Hierarchy of a **LIST** or a **STRUCTURE** shall be traversed to access any RAN parameter within the **LIST** or **STRUCTURE** + +Note that a RAN parameter may be associated with as a key where its corresponding *Key Flag* is set to “TRUE”. These RAN parameters serve as a reference to other RAN parameters within a structure that may be a part of **LIST** to enable the E2 Node interpret the scope of RAN parameters that are controlled by Near-RT RIC. + +If the “key flag” is specified in the *RIC Event Trigger Definition* IE, then the RAN parameters corresponding to “that specific itemized structure” in the list indexed by the “key flag” are subject to test condition, but if the “key flag” is not mentioned in the *RIC Event Trigger Definition* IE, then the RAN parameters corresponding to “any itemized structure” within the list are subject to test condition. + +For e.g., The ‘QFI’ can be considered a ‘key parameter’ to identify a QoS flow among the list of flows in a UE-specific PDU session. If the QFI parameter is NOT mentioned and the RIC subscribes to an event pertaining to 5QI 8, then “any QoS flow” in the list of flows of a PDU session for the UE that matches the condition of 5QI being equal to 8 would be covered by this event trigger definition. On the other hand, if the QFI parameter is mentioned in the *RIC Event Trigger Definition* IE, then only that specific QoS flow pertaining to the indicated QFI within the list is covered. + +### 8.1 RAN parameters for Event Trigger + +The RAN Parameters pertaining to “Event Trigger” that are used across multiple service styles are listed here. All RAN Parameters defined in clause 8.1 may also be used to define Policy Condition, see also clause 8.5. + +#### 8.1.1 Common RAN Parameters + +This section contains the common set of RAN parameters that can be accessed via RAN parameters defined in each service style across multiple services. + +##### 8.1.1.1 NR Cell + +The following RAN Parameters are associated with the NR cell. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------|--------------------------|----------|--------------------------------------------------------|----------------------------------------------------------| +| 10001 | NR CGI | ELEMENT | FALSE | NR CGI IE in TS 38.423 [15] Clause 9.2.2.7 | | +| 10002 | NR PCI | ELEMENT | FALSE | NR PCI IE in TS 38.473 [19] Clause 9.3.1.10 | | +| 10003 | 5GS TAC | ELEMENT | FALSE | 5GS TAC IE in TS 38.473 [19] Clause 9.3.1.29 | | +| 10004 | CHOICE NR-Mode-Info | STRUCTURE | | | NR-Mode-Info IE in TS 38.473 [19] Clause 9.3.1.10 | +| 10005 | >FDD | STRUCTURE | | | FDD IE in TS 38.473 [19] Clause 9.3.1.10 | +| 10006 | >>FDD Info | STRUCTURE | | | FDD Info IE in TS 38.473 [19] Clause 9.3.1.10 | +| 10007 | >>>UL FreqInfo | STRUCTURE | | | UL FreqInfo IE in TS 38.473 [19] Clause 9.3.1.10 | +| 10008 | >>>>NR ARFCN | ELEMENT | FALSE | NR ARFCN IE in TS 38.473 [19] Clause 9.3.1.17 | | +| 10009 | >>>>Frequency Band List | LIST | | | Frequency Band List IE in TS 38.473 [19] Clause 9.3.1.17 | +| 10010 | >>>>>Frequency Band item | STRUCTURE | | | Frequency Band Item IE in TS 38.473 [19] Clause 9.3.1.17 | +| 10011 | >>>>>>NR Frequency band | ELEMENT | FALSE | NR Frequency Band IE in TS 38.473 [19] Clause 9.3.1.17 | | +| 10012 | >>>DL FreqInfo | STRUCTURE | | | DL FreqInfo IE in TS 38.473 [19] Clause 9.3.1.10 | +| 10013 | >>>>NR ARFCN | ELEMENT | FALSE | NR ARFCN IE in TS 38.473 [19] Clause 9.3.1.17 | | +| 10014 | >>>>Frequency Band List | LIST | | | Frequency Band List IE in TS 38.473 [19] Clause 9.3.1.17 | + +| | | | | | | +|-------|------------------------------|-----------|-------|---------------------------------------------------------------|--------------------------------------------------------------------| +| 10015 | >>>>>Frequency Band item | STRUCTURE | | | <i>Frequency Band Item</i> IE in TS 38.473 [19] Clause 9.3.1.17 | +| 10016 | >>>>>NR Frequency band | ELEMENT | FALSE | <i>NR Frequency Band</i> IE in TS 38.473 [19] Clause 9.3.1.17 | | +| 10017 | >>>UL Transmission Bandwidth | STRUCTURE | | | <i>Transmission Bandwidth</i> IE in TS 38.473 [19] Clause 9.3.1.15 | +| 10018 | >>>>NR SCS | ELEMENT | FALSE | <i>NR SCS</i> IE in TS 38.473 [19] Clause 9.3.1.15 | | +| 10019 | >>>>NRB | ELEMENT | FALSE | <i>NRB</i> IE in TS 38.473 [19] Clause 9.3.1.15 | | +| 10020 | >>>DL Transmission Bandwidth | STRUCTURE | | | <i>Transmission Bandwidth</i> IE in TS 38.473 [19] Clause 9.3.1.15 | +| 10021 | >>>>NR SCS | ELEMENT | FALSE | <i>NR SCS</i> IE in TS 38.473 [19] Clause 9.3.1.15 | | +| 10022 | >>>>NRB | ELEMENT | FALSE | <i>NRB</i> IE in TS 38.473 [19] Clause 9.3.1.15 | | +| 10023 | >>>UL Carrier List | LIST | | | <i>UL Carrier List</i> IE in TS 38.473 [19] Clause 9.3.1.10 | +| 10024 | >>>>NR Carrier Item | STRUCTURE | | <i>NR Carrier Item</i> IE in TS 38.473 [19] Clause 9.3.1.137 | | +| 10025 | >>>>>NR SCS | ELEMENT | FALSE | <i>NR SCS</i> IE in TS 38.473 [19] Clause 9.3.1.15 | | +| 10026 | >>>>>Offset to Carrier | ELEMENT | FALSE | <i>Offset to Carrier</i> IE in TS 38.473 [19] Sec 137 | | +| 10027 | >>>>>Carrier Bandwidth | ELEMENT | FALSE | <i>Carrier Bandwidth</i> IE | | +| 10028 | >>>DL Carrier List | LIST | | | <i>DL Carrier List</i> IE in TS 38.473 [19] Clause 9.3.1.10 | +| 10029 | >>>>NR Carrier Item | STRUCTURE | | <i>NR Carrier Item</i> IE in TS 38.473 [19] Clause 9.3.1.137 | | +| 10030 | >>>>>NR SCS | ELEMENT | FALSE | <i>NR SCS</i> IE in TS 38.473 | | + +| | | | | | | +|-------|---------------------------|-----------|-------|----------------------------------------------------------------|--------------------------------------------------------------------| +| | | | | [19] Clause 9.3.1.15 | | +| 10031 | >>>>>Offset to Carrier | ELEMENT | FALSE | <i>Offset to Carrier</i> IE in TS 38.473 [19] Clause 9.3.1.137 | | +| 10032 | >>>>>Carrier Bandwidth | ELEMENT | FALSE | <i>Carrier Bandwidth</i> IE in TS 38.473 [19] Clause 9.3.1.137 | | +| 10033 | >TDD | STRUCTURE | | | <i>TDD</i> IE in TS 38.473 [19] Clause 9.3.1.10 | +| 10034 | >>TDD Info | STRUCTURE | | | <i>TDD Info</i> IE in TS 38.473 [19] Clause 9.3.1.10 | +| 10035 | >>>NR FreqInfo | STRUCTURE | | | | +| 10036 | >>>>NR ARFCN | ELEMENT | FALSE | <i>NR ARFCN</i> IE in TS 38.473 [19] Clause 9.3.1.17 | | +| 10037 | >>>>Frequency Band List | LIST | | | <i>Frequency Band List</i> IE in TS 38.473 [19] Clause 9.3.1.17 | +| 10038 | >>>>>Frequency Band item | STRUCTURE | | | <i>Frequency Band Item</i> IE in TS 38.473 [19] Clause 9.3.1.17 | +| 10039 | >>>>>>NR Frequency band | ELEMENT | FALSE | <i>NR Frequency Band</i> IE in TS 38.473 [19] Clause 9.3.1.17 | | +| 10040 | >>>Transmission Bandwidth | STRUCTURE | | | <i>Transmission Bandwidth</i> IE in TS 38.473 [19] Clause 9.3.1.15 | +| 10041 | >>>>NR SCS | ELEMENT | FALSE | <i>NR SCS</i> IE in TS 38.473 [19] Clause 9.3.1.15 | | +| 10042 | >>>>NRB | ELEMENT | FALSE | <i>NRB</i> IE in TS 38.473 [19] Clause 9.3.1.15 | | +| 10043 | >>>Carrier List | LIST | | | <i>Transmission Bandwidth</i> IE in TS 38.473 [19] Clause 9.3.1.15 | +| 10044 | >>>>NR Carrier Item | STRUCTURE | | <i>NR SCS</i> IE in TS 38.473 [19] Clause 9.3.1.15 | | +| 10045 | >>>>>>NR SCS | ELEMENT | FALSE | <i>NR SCS</i> IE in TS 38.473 | | + +| | | | | | | +|-------|----------------------------------------|-----------|-------|-------------------------------------------------------------------------------|------------------------------------------------------------------------------| +| | | | | [19] Clause 9.3.1.15 | | +| 10046 | >>>>>Offset to Carrier | ELEMENT | FALSE | <i>Offset to Carrier</i> IE in TS 38.473 [19] Clause 9.3.1.137 | | +| 10047 | >>>>>Carrier Bandwidth | ELEMENT | FALSE | <i>Carrier Bandwidth</i> IE in TS 38.473 [19] Clause 9.3.1.137 | | +| 10048 | >>>Intended TDD DL-UL Configuration | STRUCTURE | | | <i>Intended TDD DL-UL Configuration</i> IE in TS 38.473 [19] Clause 9.3.1.89 | +| 10049 | >>>>NR SCS | ELEMENT | FALSE | <i>NR SCS</i> IE in TS 38.473 [19] Clause 9.3.1.89 | | +| 10050 | >>>>NR Cyclic Prefix | ELEMENT | FALSE | <i>NR Cyclic Prefix</i> IE in TS 38.473 [19] Clause 9.3.1.89 | | +| 10051 | >>>>NR DL-UL Transmission Periodicity | ELEMENT | FALSE | <i>NR DL-UL Transmission Periodicity</i> IE in TS 38.473 [19] Clause 9.3.1.89 | | +| 10052 | >>>>Slot Configuration List | LIST | | | <i>Slot Configuration List</i> IE in TS 38.473 [19] Clause 9.3.1.89 | +| 10053 | >>>>>Slot Configuration Item | STRUCTURE | | | <i>Slot Configuration Item</i> IE in TS 38.473 [19] Clause 9.3.1.89 | +| 10054 | >>>>>>Slot Index | ELEMENT | TRUE | <i>Slot Index</i> IE in TS 38.473 [19] Clause 9.3.1.89 | | +| 10055 | >>>>>>CHOICE Symbol Allocation in Slot | STRUCTURE | | <i>Symbol Allocation in Slot</i> IE in TS 38.473 [19] Clause 9.3.1.89 | | +| 10056 | >>>>>>>All DL | ELEMENT | FALSE | <i>All DL</i> IE in TS 38.473 [19] Clause 9.3.1.89 | | +| 10057 | >>>>>>>All UL | ELEMENT | FALSE | <i>All UL</i> IE in TS 38.473 [19] Clause 9.3.1.89 | | +| 10058 | >>>>>>>Both DL and UL | STRUCTURE | | | <i>Both DL and UL</i> IE in TS 38.473 [19] Clause | + +| | | | | | | +|-------|--------------------------------------------|-----------|-------|-----------------------------------------------------------|---------------------------------------------------------------------------| +| | | | | | 9.3.1.89 | +| 10059 | >>>>>>>Number of DL symbols | ELEMENT | FALSE | Number of DL symbols IE in TS 38.473 [19] Clause 9.3.1.89 | | +| 10060 | >>>>>>>Number of UL symbols | ELEMENT | FALSE | Number of UL symbols IE in TS 38.473 [19] Clause 9.3.1.89 | | +| 10061 | Count of FDD UL Frequency band list | ELEMENT | FALSE | INTEGER (0..63) | | +| 10062 | Count of FDD DL Frequency band list | ELEMENT | FALSE | INTEGER (0..63) | | +| 10063 | Count of FDD UL Carrier list | ELEMENT | FALSE | INTEGER (0..63) | | +| 10064 | Count of FDD DL Carrier list | ELEMENT | FALSE | INTEGER (0..63) | | +| 10065 | Count of TDD Frequency band list | ELEMENT | FALSE | INTEGER (0..63) | | +| 10066 | Count of TDD Carrier list | ELEMENT | FALSE | INTEGER (0..63) | | +| 10067 | Count of TDD DL-UL Slot Configuration list | ELEMENT | FALSE | INTEGER (0..63) | | +| 10101 | Reported NR RRC Measurements | STRUCTURE | | | measResult IE in TS 38.331 [22] | +| 10102 | >Cell Results | STRUCTURE | | | cellResults IE in TS 38.331 [22] | +| 10103 | >>SSB Results | STRUCTURE | | 8.1.1.3 | resultsSSB-Cell IE in TS 38.331 [22] | +| 10106 | >>CSI-RS Results | STRUCTURE | | 8.1.1.3 | resultsCSI-RS-Cell IE in TS 38.331 [22] | +| 10110 | PM Measurements | STRUCTURE | | | Cell Measurement Result IE in TS 38.423 [15] Clause 9.1.3.21 | +| 10111 | >Radio Resource Status | STRUCTURE | | | Radio Resource Status IE in TS 38.473 [19] | +| 10112 | >>SSB Area Radio Resource Status List | LIST | | | SSB Area Radio Resource Status List IE in TS 38.473 [19] Clause 9.3.1.129 | +| 10113 | >>>SSB Area Radio Resource Status Item | STRUCTURE | | | SSB Area Radio Resource Status Item IE in TS 38.473 [19] Clause 9.3.1.129 | +| 10114 | >>>>SSB Index | ELEMENT | TRUE | SSB Index IE in TS 38.473 [19] Clause 9.3.1.129 | | + +| | | | | | | +|-------|--------------------------------------|---------|-------|----------------------------------------------------------------------------|------------------------------------------------------------------| +| 10115 | >>>>SSB Area DL GBR PRB Usage | ELEMENT | FALSE | <i>SSB Area DL GBR PRB Usage</i> IE in TS 38.473 [19] Clause 9.3.1.129 | | +| 10116 | >>>>SSB Area UL GBR PRB Usage | ELEMENT | FALSE | <i>SSB Area UL GBR PRB Usage</i> IE in TS 38.473 [19] Clause 9.3.1.129 | | +| 10117 | >>>>SSB Area DL non-GBR PRB Usage | ELEMENT | FALSE | <i>SSB Area DL non-GBR PRB Usage</i> IE in TS 38.473 [19] Clause 9.3.1.129 | | +| 10118 | >>>>SSB Area UL non-GBR PRB Usage | ELEMENT | FALSE | <i>SSB Area UL non-GBR PRB Usage</i> IE in TS 38.473 [19] Clause 9.3.1.129 | | +| 10119 | >>>>SSB Area DL Total PRB Usage | ELEMENT | FALSE | <i>SSB Area DL Total PRB Usage</i> IE in TS 38.473 [19] Clause 9.3.1.129 | | +| 10120 | >>>>SSB Area UL Total PRB Usage | ELEMENT | FALSE | <i>SSB Area UL Total PRB Usage</i> IE in TS 38.473 [19] Clause 9.3.1.129 | | +| 10121 | >>>>DL scheduling PDCCH CCE Usage | ELEMENT | FALSE | <i>DL Scheduling PDCCH CCE</i> IE in TS 38.473 [19] Clause 9.3.1.129 | | +| 10122 | >>>>UL scheduling PDCCH CCE Usage | ELEMENT | FALSE | <i>UL Scheduling PDCCH CCE</i> IE in TS 38.473 [19] Clause 9.3.1.129 | | +| 10123 | >Available DL PRBs in the cell | ELEMENT | FALSE | INTEGER | <i>DL Total available PRB</i> IE in TS 28.552 [28] Sec 5.1.1.2.6 | +| 10124 | >Available UL PRBs in the cell | ELEMENT | FALSE | INTEGER | <i>UL Total available PRB</i> IE in TS 28.552 [28] Sec 5.1.1.2.8 | +| 10125 | >Number of active DL UEs in the cell | ELEMENT | FALSE | <i>Number of Active UEs</i> IE in TS 38.473 [19] Clause 9.3.1.135 | | + +| | | | | | | +|-------|-----------------------------------------|-----------|-------|------------------------------------------------------------------------|---------------------------------------------------------------------------------| +| 10126 | >Number of active UL UEs in the cell | ELEMENT | FALSE | <i>Number of Active UEs IE</i> in TS 38.473 [19] Clause 9.3.1.135 | | +| 10127 | >Composite Available Capacity Group | STRUCTURE | | | <i>Composite Available Capacity Group IE</i> in TS 38.473 [19] Clause 9.3.1.130 | +| 10128 | >>Composite Available Capacity Downlink | STRUCTURE | | | <i>Composite Available Capacity IE</i> in TS 38.473 [19] Clause 9.3.1.131 | +| 10129 | >>>Cell Capacity Class Value | ELEMENT | FALSE | <i>Cell Capacity Class Value IE</i> in TS 38.473 [19] Clause 9.3.1.132 | | +| 10130 | >>>Capacity Value | ELEMENT | FALSE | <i>Capacity Value IE</i> in TS 38.473 [19] Clause 9.3.1.133 | | +| 10131 | >>>SSB Area Capacity Value List | LIST | | | <i>SSB Area Capacity Value List IE</i> in TS 38.473 [19] Clause 9.3.1.133 | +| 10132 | >>>>SSB Area Capacity Value Item | STRUCTURE | | | <i>SSB Area Capacity Value Item IE</i> in TS 38.473 [19] Sec 9.3.1.133 | +| 10133 | >>>>>SSB Index | ELEMENT | TRUE | <i>SSB Index IE</i> in TS 38.473 [19] Clause 9.3.1.133 | | +| 10134 | >>>>>SSB Area Capacity Value | ELEMENT | FALSE | <i>SSB Area Capacity Value IE</i> in TS 38.473 [19] Sec 9.3.1.133 | | +| 10141 | >>Composite Available Capacity Uplink | STRUCTURE | | | <i>Composite Available Capacity IE</i> in TS 38.473 [19] Clause 9.3.1.131 | +| 10142 | >>>Cell Capacity Class Value | ELEMENT | FALSE | <i>Cell Capacity Class Value IE</i> in TS 38.473 [19] Clause 9.3.1.132 | | +| 10143 | >>>Capacity Value | ELEMENT | FALSE | <i>Capacity Value IE</i> in TS 38.473 [19] Clause 9.3.1.133 | | + +| | | | | | | +|-------|----------------------------------------------|-----------|-------|----------------------------------------------------------------------------|------------------------------------------------------------------------------| +| 10144 | >>>SSB Area Capacity Value List | LIST | | | <i>SSB Area Capacity Value List</i> IE in TS 38.473 [19] Clause 9.3.1.133 | +| 10145 | >>>>SSB Area Capacity Value Item | STRUCTURE | | | <i>SSB Area Capacity Value Item</i> IE in TS 38.473 [19] Sec 9.3.1.133 | +| 10146 | >>>>>SSB Index | ELEMENT | TRUE | <i>SSB Index</i> IE in TS 38.473 [19] Clause 9.3.1.133 | | +| 10147 | >>>>>SSB Area Capacity Value | ELEMENT | FALSE | <i>SSB Area Capacity Value</i> IE in TS 38.473 [19] Sec 9.3.1.133 | | +| 10151 | >Slice Available Capacity List | LIST | | | <i>Slice Available Capacity List</i> IE in TS 38.473 [19] Clause 9.3.1.134 | +| 10152 | >>Slice Available Capacity Item | STRUCTURE | | | <i>Slice Available Capacity Item</i> IE in TS 38.473 [19] Clause 9.3.1.134 | +| 10153 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.473 [19] Clause 9.3.1.14 | | +| 10154 | >>>S-NSSAI Available Capacity List | LIST | | | <i>S-NSSAI Available Capacity List</i> IE in TS 38.473 [19] Clause 9.3.1.134 | +| 10155 | >>>>S-NSSAI Available Capacity Item | STRUCTURE | | | <i>S-NSSAI Available Capacity Item</i> IE in TS 38.473 [19] Clause 9.3.1.134 | +| 10156 | >>>>>S-NSSAI | STRUCTURE | FALSE | | <i>S-NSSAI</i> IE in TS 38.473 [19] Clause 9.3.1.38 | +| 10160 | >>>>>>SST | ELEMENT | FALSE | <i>SST</i> IE in TS 38.473 [19] Clause 9.3.1.38 | | +| 10161 | >>>>>>SD | ELEMENT | FALSE | <i>SD</i> IE in TS 38.473 [19] Clause 9.3.1.38 | | +| 10157 | >>>>>Slice Available Capacity Value Downlink | ELEMENT | FALSE | <i>Slice Available Capacity Value Downlink</i> IE in TS 38.473 [19] Clause | | + +| | | | | | | +|-------|-----------------------------------------------|---------|-------|------------------------------------------------------------------------------------------------------------|--| +| | | | | 9.3.1.134 | | +| 10158 | >>>>>Slice Available<br>Capacity Value Uplink | ELEMENT | FALSE | <i>Slice<br/>Available<br/>Capacity<br/>Value Uplink</i><br>IE in TS<br>38.473 [19]<br>Clause<br>9.3.1.134 | | +| 10201 | Cell-specific offset | ELEMENT | FALSE | Ocp (or Ocn)<br>IE as defined<br>in TS 38.331<br>[22]<br>INTEGER | | +| 10202 | Cell Measurement object specific offset | ELEMENT | FALSE | Ofp (or Ofn)<br>IE as defined<br>in TS 38.331<br>[22]<br>INTEGER | | + +### 8.1.1.2 E-UTRA Cell + +The following RAN Parameters are associated with the E-UTRA cell. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-------------------------------|--------------------------|----------|--------------------------------------------------------------------------|--------------------------------------------------------------------| +| 12001 | E-UTRA CGI | ELEMENT | FALSE | <i>E-UTRA CGI</i> IE in TS 36.423 [15] Clause 9.2.2.8 | | +| 12002 | PCI | ELEMENT | FALSE | <i>PCI</i> IE in TS 36.423 [15] within Clause 9.2.8, INTEGER(0..503,...) | | +| 12003 | TAC | ELEMENT | FALSE | <i>TAC</i> IE in TS 36.423 [15] within Clause 9.2.8, OCTET STRING(2) | | +| 12004 | CHOICE <i>EUTRA-Mode-Info</i> | STRUCTURE | | | <i>EUTRA-Mode-Info</i> IE in TS 36.423 [17] Clause 9.2.8 | +| 12005 | >FDD | STRUCTURE | | | <i>FDD</i> IE in TS 36.423 [17] Clause 9.2.8 | +| 12006 | >>FDD Info | STRUCTURE | | | <i>FDD Info</i> IE in TS 36.423 [17] Clause 9.2.8 | +| 12007 | >>>UL EARFCN | STRUCTURE | | | <i>UL EARFCN</i> IE in TS 36.423 [17] Clause 9.2.8 | +| 12008 | >>>>EARFCN | ELEMENT | FALSE | <i>EARFCN</i> IE in TS 36.423 [17] Clause 9.2.26 | | +| 12009 | >>>DL EARFCN | ELEMENT | FALSE | | <i>DL EARFCN</i> IE in TS 36.423 [17] Clause 9.2.8 | +| 12010 | >>>>EARFCN | STRUCTURE | | <i>EARFCN</i> IE in TS 36.423 [17] Clause 9.2.26 | | +| 12011 | >>>UL Transmission Bandwidth | STRUCTURE | | | <i>UL Transmission Bandwidth</i> IE in TS 36.423 [17] Clause 9.2.8 | +| 12012 | >>>>Transmission Bandwidth | ELEMENT | FALSE | <i>Transmission Bandwidth</i> IE in TS 36.423 [17] Clause 9.2.27 | | +| 12013 | >>>DL Transmission Bandwidth | STRUCTURE | | | <i>DL Transmission Bandwidth</i> IE in TS 36.423 [17] | + +| | | | | | | +|-------|-------------------------------|-----------|-------|--------------------------------------------------------------------|-----------------------------------------------------------------------| +| | | | | | Clause 9.2.8 | +| 12014 | >>>>Transmission Bandwidth | ELEMENT | FALSE | <i>Transmission Bandwidth IE</i> in TS 36.423 [17] Clause 9.2.27 | | +| 12015 | >TDD | STRUCTURE | | | <i>TDD IE</i> in TS 36.423 [17] Clause 9.2.8 | +| 12016 | >>TDD Info | STRUCTURE | | | <i>TDD Info IE</i> in TS 36.423 [17] Clause 9.2.8 | +| 12017 | >>>EARFCN | ELEMENT | FALSE | <i>EARFCN IE</i> in TS 36.423 [17] Clause 9.2.26 | | +| 12018 | >>>Transmission Bandwidth | ELEMENT | FALSE | <i>Transmission Bandwidth IE</i> in TS 36.423 [17] Clause 9.2.27 | | +| 12019 | >>>Subframe assignment | ELEMENT | FALSE | <i>Subframe Assignment IE</i> in TS 36.423 [17] Clause 9.2.8 | | +| 12020 | >>>Special Subframe Info | ELEMENT | FALSE | <i>Special Subframe Info IE</i> in TS 36.423 [17] Clause 9.2.8 | | +| 12021 | >>>>Special Subframe Patterns | ELEMENT | FALSE | <i>Special Subframe Patterns IE</i> in TS 36.423 [17] Clause 9.2.8 | | +| 12022 | >>>>Cyclic Prefix DL | ELEMENT | FALSE | <i>Cyclic Prefix DL IE</i> in TS 36.423 [17] Clause 9.2.8 | | +| 12023 | >>>>Cyclic Prefix UL | ELEMENT | FALSE | <i>Cyclic Prefix UL IE</i> in TS 36.423 [17] Clause 9.2.8 | | +| 12024 | Reported LTE RRC Measurements | STRUCTURE | | 8.1.1.3 | <i>MeasResults IE</i> in TS 36.331 [23] | +| 12025 | PM Measurements | STRUCTURE | | | <i>CellMeasurementResultItem IE</i> in TS 36.423 [17] Clause 9.1.2.14 | +| 12026 | >Radio Resource Status | STRUCTURE | | | <i>Radio Resource Status IE</i> in TS 36.423 [17] Clause 9.2.37 | +| 12027 | >>DL GBR PRB Usage | ELEMENT | FALSE | <i>DL GBR PRB Usage IE</i> in TS 36.423 [17] Clause | | + +| | | | | | | +|-------|-----------------------------------------|-----------|-------|-------------------------------------------------------------------------|---------------------------------------------------------------------------------| +| | | | | 9.2.37 | | +| 12028 | >>UL GBR PRB Usage | ELEMENT | FALSE | <i>UL GBR PRB Usage</i> IE in TS 36.423 [17] Clause 9.2.37 | | +| 12029 | >>DL non-GBR PRB Usage | ELEMENT | FALSE | <i>DL non-GBR PRB Usage</i> IE in TS 36.423 [17] Clause 9.2.37 | | +| 12030 | >>UL non-GBR PRB usage | ELEMENT | FALSE | <i>UL non-GBR PRB Usage</i> IE in TS 36.423 [17] Clause 9.2.37 | | +| 12031 | >>DL Total PRB Usage | ELEMENT | FALSE | <i>DL Total PRB Usage</i> IE in TS 36.423 [17] Clause 9.2.37 | | +| 12032 | >>UL Total PRB Usage | ELEMENT | FALSE | <i>UL Total PRB Usage</i> IE in TS 36.423 [17] Clause 9.2.37 | | +| 12033 | >>DL scheduling PDCCH CCE Usage | ELEMENT | FALSE | <i>DL scheduling PDCCH CCE Usage</i> IE in TS 36.423 [17] Clause 9.2.37 | | +| 12034 | >>UL scheduling PDCCH CCE Usage | ELEMENT | FALSE | <i>UL scheduling PDCCH CCE Usage</i> IE in TS 36.423 [17] Clause 9.2.37 | | +| 12051 | >Composite Available Capacity Group | STRUCTURE | | | <i>Composite Available Capacity Group</i> IE in TS 36.423 [17] Clause 9.2.44 | +| 12052 | >>Composite Available Capacity Downlink | STRUCTURE | | | <i>Composite Available Capacity Downlink</i> IE in TS 36.423 [17] Clause 9.2.45 | +| 12053 | >>>Cell capacity Class Value | ELEMENT | FALSE | <i>Cell Capacity Class Value</i> IE in TS 36.423 [17] Clause 9.2.46 | | +| 12054 | >>>Capacity Value | ELEMENT | FALSE | <i>Capacity Value</i> IE in TS 36.423 | | + +| | | | | | | +|-------|----------------------------------------|-----------|-------|---------------------------------------------------------------------|-------------------------------------------------------------------------------| +| | | | | [17] Clause 9.2.47 | | +| 12055 | >>Composite Available Capacity Uplink | STRUCTURE | | | <i>Composite Available Capacity Uplink</i> IE in TS 36.423 [17] Clause 9.2.45 | +| 12056 | >>>Cell capacity Class Value | ELEMENT | FALSE | <i>Cell Capacity Class Value</i> IE in TS 36.423 [17] Clause 9.2.46 | | +| 12057 | >>>Capacity Value | ELEMENT | FALSE | <i>Capacity Value</i> IE in TS 36.423 [17] Clause 9.2.47 | | +| 12058 | >Available DL PRBs in the cell | ELEMENT | FALSE | INTEGER | | +| 12059 | >Available UL PRBs in the cell | ELEMENT | FALSE | INTEGER | | +| 12060 | >Number of active DL UEs in the cell | ELEMENT | FALSE | INTEGER | | +| 12061 | >Number of active UL UEs in the cell | ELEMENT | FALSE | INTEGER | | +| 12062 | >ABS Status | STRUCTURE | | | <i>ABS Status</i> IE in TS 36.423 [17] Clause 9.2.58 | +| 12063 | >>DL ABS Status | ELEMENT | FALSE | <i>DL ABS status</i> IE in TS 36.423 [17] Clause 9.2.58 | | +| 12064 | >>CHOICE <i>Usable ABS Information</i> | STRUCTURE | | | <i>Usable ABS Information</i> IE in TS 36.423 [17] Clause 9.2.58 | +| 12065 | >>>FDD | STRUCTURE | | | <i>FDD</i> IE in TS 36.423 [17] Clause 9.2.58 | +| 12066 | >>>>Usable ABS Pattern Info | ELEMENT | FALSE | <i>Usable ABS Pattern Info</i> IE in TS 36.423 [17] Clause 9.2.58 | | +| 12067 | >>>TDD | STRUCTURE | | | <i>TDD</i> IE in TS 36.423 [17] Clause 9.2.58 | +| 12068 | >>>>Usable ABS Pattern Info | ELEMENT | FALSE | <i>Usable ABS Pattern Info</i> IE in TS 36.423 [17] Clause 9.2.58 | | +| 12075 | >CSI Report per CSI Process List | LIST | | | <i>CSI Report per CSI Process</i> IE | + +| | | | | | | +|-------|-------------------------------------------|-----------|-------|---------------------------------------------------------------------------|---------------------------------------------------------------------------| +| | | | | | in TS 36.423 [17] Clause 9.2.79 | +| 12076 | >>CSI Process per CSI Item | STRUCTURE | | | <i>CSI Report per CSI Process Item</i> IE in TS 36.423 [17] Clause 9.2.79 | +| 12077 | >>>CSI Process Configuration Index | ELEMENT | FALSE | <i>CSI Process Configuration Index</i> IE in TS 36.423 [17] Clause 9.2.79 | | +| 12078 | >>>RI | ELEMENT | FALSE | <i>R</i> IE in TS 36.423 [17] Clause 9.2.79 | | +| 12079 | >>>Wideband CQI | STRUCTURE | | | <i>Wideband CQI</i> IE in TS 36.423 [17] Clause 9.2.80 | +| 12101 | >>>>Wideband CQI Codeword 0 | ELEMENT | FALSE | <i>Wideband CQI Codeword 0</i> IE in TS 36.423 [17] Clause 9.2.80 | | +| 12102 | >>>>CHOICE <i>Wideband CQI Codeword 1</i> | STRUCTURE | | | <i>Wideband CQI Codeword 1</i> IE in TS 36.423 [17] Clause 9.2.80 | +| 12103 | >>>>>4-bit CQI | ELEMENT | FALSE | <i>4-bit CQI</i> IE in TS 36.423 [17] Clause 9.2.80 | | +| 12104 | >>>>>3-bit spatial differential CQI | ELEMENT | FALSE | <i>3-bit spatial differential CQI</i> IE in TS 36.423 [17] Clause 9.2.80 | | +| 12080 | >>>Subband Size | ELEMENT | FALSE | <i>Subband Size</i> IE in TS 36.423 [17] Clause 9.2.79 | | +| 12081 | >>>Subband CQI List | LIST | | | <i>Subband CQI List</i> IE in TS 36.423 [17] Clause 9.2.79 | +| 12082 | >>>>Subband CQI Item | STRUCTURE | | | <i>Subband CQI Item</i> IE in TS 36.423 [17] Clause 9.2.79 | + +| | | | | | | +|-------|-----------------------------------------|-----------|-------|------------------------------------------------------------------|------------------------------------------------------------------| +| 12083 | >>>>>Subband CQI Index | ELEMENT | FALSE | <i>Subband Index</i> IE in TS 36.423 [17] Clause 9.2.79 | | +| 12084 | >>>>>Subband CQI | STRUCTURE | | | <i>Subband CQI</i> IE in TS 36.423 [17] Clause 9.2.81 | +| 12085 | >>>>>>CHOICE<br>Subband CQI Codeword 0 | STRUCTURE | | | <i>Subband CQI Codeword 0</i> IE in TS 36.423 [17] Clause 9.2.81 | +| 12086 | >>>>>>>4-bit CQI | ELEMENT | FALSE | <i>4-bit CQI</i> IE in TS 36.423 [17] Clause 9.2.81 | | +| 12087 | >>>>>>>2-bit subband differential CQI | ELEMENT | FALSE | <i>2-bit Subband differential CQI</i> IE in 36.423 Clause 9.2.81 | | +| 12088 | >>>>>>>2-bit differential CQI | ELEMENT | FALSE | <i>2-bit differential CQI</i> IE in 36.423 Clause 9.2.81 | | +| 12089 | >>>>>>>CHOICE<br>Subband CQI Codeword 1 | STRUCTURE | | | <i>Subband CQI Codeword 1</i> IE in TS 36.423 [17] Clause 9.2.81 | +| 12090 | >>>>>>>4-bit CQI | ELEMENT | FALSE | <i>4-bit CQI</i> IE in TS 36.423 [17] Clause 9.2.81 | | +| 12091 | >>>>>>>3-bit spatial differential CQI | ELEMENT | FALSE | <i>3-bit spatial differential CQI</i> IE in 36.423 Clause 9.2.81 | | +| 12092 | >>>>>>>2-bit subband differential CQI | ELEMENT | FALSE | <i>2-bit Subband differential CQI</i> IE in 36.423 Clause 9.2.81 | | +| 12093 | >>>>>>>2-bit differential CQI | ELEMENT | FALSE | <i>2-bit differential CQI</i> IE in 36.423 Clause 9.2.81 | | + +### 8.1.1.3 RRC Signal Measurements + +The following RAN Parameters are associated with RRC measurements. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------|--------------------------|----------|----------------------------------------|-----------------------| +| 12501 | RSRP | ELEMENT | FALSE | <i>RSRP-Range</i> IE in TS 38.331 [22] | | +| 12502 | RSRQ | ELEMENT | FALSE | <i>RSRQ-Range</i> IE in TS 38.331 [22] | | +| 12503 | SINR | ELEMENT | FALSE | <i>SINR-Range</i> IE in TS 38.331 [22] | | + +### 8.1.1.4 L2 MAC State Variables + +The following RAN Parameters are associated with UE-specific L2 MAC state variables. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------|--------------------------|----------|--------------------------|---------------------------------------------------------------------------------------------------------------------------| +| 13001 | Buffer Occupancy | STRUCTURE | | | Buffer Occupancy (BO) in number of bytes as defined in TS 25.321 [27] clause 8.2.2(c). LCID indicates logical channel ID. | +| 13002 | >LCID | ELEMENT | TRUE | INTEGER (0.. 63) | | +| 13003 | >BO in Bytes | ELEMENT | FALSE | INTEGER | | +| 13004 | Buffer Status Report | STRUCTURE | | | MCE Control Elements as defined in TS 38.321 [26] clause 6.1.3. | +| 13005 | >Short BSR | ELEMENT | FALSE | OCTET STRING (SIZE(1)) | | +| 13006 | >Long BSR | ELEMENT | FALSE | OCTET STRING | | +| 13007 | >Short Truncated BSR | ELEMENT | FALSE | OCTET STRING (SIZE(1)) | | +| 13008 | >Long Truncated BSR | ELEMENT | FALSE | OCTET STRING | | +| 13009 | >Pre-emptive BSR | ELEMENT | FALSE | OCTET STRING | | +| 13010 | SCell Activation/Deactivation | STRUCTURE | | | | +| 13011 | >One Octet | ELEMENT | FALSE | OCTET STRING (SIZE(1)) | | +| 13012 | >Four Octet | ELEMENT | FALSE | OCTET STRING (SIZE(4)) | | +| 13013 | Duplication Activation/Deactivation | ELEMENT | FALSE | OCTET STRING (SIZE(1)) | | +| 13014 | Duplication RLC Activation/Deactivation | ELEMENT | FALSE | OCTET STRING (SIZE(1)) | | + +### 8.1.1.5 NG-RAN Data Radio Bearer + +The following RAN Parameters are associated with the NG-RAN data radio bearer. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------|--------------------------|----------|----------------------------------------------------------------------------|-------------------------------------------------------------------------------| +| 14001 | 5QI | ELEMENT | FALSE | 5QI IE in TS 37.483 [21] Clause 9.3.1.27 or TS 37.483 [21] Clause 9.3.1.28 | | +| 14002 | Packet Delay Budget | ELEMENT | FALSE | Packet Delay Budget IE in TS 37.483 [21] Clause 9.3.1.47 | | +| 14003 | Packet Error Rate | ELEMENT | FALSE | Packet Error Rate IE in TS 37.483 [21] Clause 9.3.1.48 | | +| 14004 | NG-RAN DRB Allocation and Retention Priority | STRUCTURE | | | NG-RAN Allocation and Retention Priority IE in TS 37.483 [21] Clause 9.3.1.29 | +| 14005 | >Priority Level | ELEMENT | FALSE | Priority Level IE in TS 37.483 [21] Clause 9.3.1.29 | | +| 14006 | >Pre-emption Capability | ELEMENT | FALSE | Pre-emption Capability IE in TS 37.483 [21] Clause 9.3.1.29 | | +| 14007 | >Pre-emption Vulnerability | ELEMENT | FALSE | Pre-emption Vulnerability IE in TS 37.483 [21] Clause 9.3.1.29 | | +| 14008 | Priority Level of the mapped QoS flows | ELEMENT | FALSE | Priority Level IE in TS 37.483 [21] Clause 9.3.1.51 | | +| 14009 | QoS parameters for GBR flows in NG-RAN Bearer | STRUCTURE | | | GBR QoS Flow Information IE in TS 37.483 [21] Clause 9.3.1.30 | +| 14010 | >Maximum Flow Bit Rate Downlink | ELEMENT | FALSE | Bit Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 14011 | >Guaranteed Flow Bit Rate Downlink | ELEMENT | FALSE | Bit Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 14012 | >Maximum Packet Loss Rate Downlink | ELEMENT | FALSE | Packet Loss Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 14013 | >Maximum Flow Bit Rate Uplink | ELEMENT | FALSE | Bit Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 14014 | >Guaranteed Flow Bit Rate Uplink | ELEMENT | FALSE | Bit Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 14015 | >Maximum Packet Loss Rate Uplink | ELEMENT | FALSE | Packet Loss Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 14016 | QoS Monitoring Enable Request | ELEMENT | FALSE | QoS Monitoring Request IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 14017 | QoS Monitoring Reporting Frequency | ELEMENT | FALSE | QoS Monitoring Reporting Frequency IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 14018 | QoS Monitoring Disabled | ELEMENT | FALSE | QoS Monitoring Disabled IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 14019 | Reflective QoS Mapping | ELEMENT | FALSE | RDI IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 14101 | List of cell groups to be added | LIST | | | Cell Group To Add IE in TS 37.483 [21] Clause 9.3.3.11 | +| 14102 | >Cell group item | STRUCTURE | | | Cell Group Item IE in TS 37.483 [21] Clause 9.3.1.11 | +| 14103 | >>Cell Group ID | ELEMENT | TRUE | Cell Group ID IE in TS 37.483 [21] Clause | | + +| | | | | | | +|-------|--------------------------------|-----------|-------|-------------------------------------------------------------------------------------|----------------------------------------------------------------| +| | | | | 9.3.1.11 | | +| 14104 | >>Cell Group | STRUCTURE | | 8.1.1.7 | | +| 14201 | SDAP Configuration | STRUCTURE | | | <i>SDAP Configuration IE</i> in TS 37.483 [21] Clause 9.3.1.39 | +| 14202 | >PDU Session ID | ELEMENT | TRUE | <i>PDU-SessionID IE</i> in TS 38.331 [22] Sec 6 | | +| 14203 | >Default DRB | ELEMENT | FALSE | <i>Default DRB IE</i> in TS 37.483 [21] Clause 9.3.1.39 | | +| 14210 | >PDU Session | STRUCTURE | | 8.1.1.16 | | +| 14301 | PDCP Configuration | STRUCTURE | | | <i>PDCP Configuration IE</i> in TS 37.483 [21] Clause 9.3.1.38 | +| 14302 | >RLC mode | ELEMENT | FALSE | <i>RLC mode IE</i> in TS 37.483 [21] Clause 9.3.1.38 | | +| 14303 | >PDCP Duplication | ELEMENT | FALSE | <i>PDCP Duplication IE</i> in TS 37.483 [21] Clause 9.3.1.38 | | +| 14304 | >UL Data Split Threshold | ELEMENT | FALSE | <i>UL Data Split Threshold IE</i> in TS 37.483 [21] Clause 9.3.1.43 | | +| 14305 | >PDCP Re-establishment | ELEMENT | FALSE | <i>PDCP Re-establishment IE</i> in TS 37.483 [21] Clause 9.3.1.38 | | +| 14306 | >PDCP Data Recovery | ELEMENT | FALSE | <i>PDCP Data Recovery IE</i> in TS 37.483 [21] Clause 9.3.1.38 | | +| 14307 | >Out-of-Order Delivery | ELEMENT | FALSE | <i>Out of Order Delivery IE</i> in TS 37.483 [21] Clause 9.3.1.38 | | +| 14308 | >PDCP Status Report Indication | ELEMENT | FALSE | <i>PDCP Status Report Indication IE</i> in TS 37.483 [21] Clause 9.3.1.38 | | +| 14309 | >Number of PDCP duplication | ELEMENT | FALSE | <i>Additional PDCP duplication Information IE</i> in TS 37.483 [21] Clause 9.3.1.38 | | +| 14310 | >UL More than one RLC | STRUCTURE | | | <i>moreThanOneRLC IE</i> in TS 38.331 [22] Clause 6 | +| 14311 | >>Primary Path | STRUCTURE | | | <i>primaryPath IE</i> in TS 38.331 [22] Clause 6 | +| 14312 | >>>Cell Group ID | ELEMENT | TRUE | <i>cellGroup IE</i> in TS 38.331 [22] Clause 6 | | +| 14313 | >>>Logical Channel ID | ELEMENT | FALSE | <i>logicalChannelIdentity IE</i> in TS 38.331 [22] Sec 6 | | +| 14314 | >UL More than two RLC | STRUCTURE | | | <i>moreThanTwoRLC-DRB-r16 IE</i> in TS 38.331 [22] Clause 6 | +| 14315 | >>Split Secondary Path | ELEMENT | FALSE | <i>splitSecondaryPath IE</i> in TS 38.331 [22] Sec 6 | | +| 14316 | >>Duplication State | ELEMENT | FALSE | <i>duplicationState IE</i> in TS 38.331 [22] Sec 6 | | +| 14317 | Averaging Window | ELEMENT | FALSE | <i>Averaging Window IE</i> in TS 37.483 [21] Clause 9.3.1.49 | | +| 14318 | Delay Critical | ELEMENT | FALSE | <i>Delay Critical IE</i> in TS 37.483 [21] Clause 9.3.1.28 | | +| 14319 | Maximum Data Burst Volume | ELEMENT | FALSE | <i>Maximum Data Burst Volume IE</i> in TS 37.483 [21] Clause 9.3.1.50 | | + +### 8.1.1.6 QoS flow + +The following RAN Parameters are associated with the NG-RAN QoS flow. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------|--------------------------|----------|----------------------------------------------------------------------------|-------------------------------------------------------------------------------| +| 15001 | 5QI | ELEMENT | FALSE | 5QI IE in TS 37.483 [21] Clause 9.3.1.27 or TS 37.483 [21] Clause 9.3.1.28 | | +| 15002 | Packet Delay Budget | ELEMENT | FALSE | Packet Delay Budget IE in TS 37.483 [21] Clause 9.3.1.47 | | +| 15003 | Packet Error Rate | ELEMENT | FALSE | Packet Error Rate IE in TS 37.483 [21] Clause 9.3.1.48 | | +| 15004 | NG-RAN DRB Allocation and Retention Priority | STRUCTURE | | | NG-RAN Allocation and Retention Priority IE in TS 37.483 [21] Clause 9.3.1.29 | +| 15005 | >Priority Level | ELEMENT | FALSE | Priority Level IE in TS 37.483 [21] Clause 9.3.1.29 | | +| 15006 | >Pre-emption Capability | ELEMENT | FALSE | Pre-emption Capability IE in TS 37.483 [21] Clause 9.3.1.29 | | +| 15007 | >Pre-emption Vulnerability | ELEMENT | FALSE | Pre-emption Vulnerability IE in TS 37.483 [21] Clause 9.3.1.29 | | +| 15008 | Priority Level of the mapped QoS flows | ELEMENT | FALSE | Priority Level IE in TS 37.483 [21] Clause 9.3.1.51 | | +| 15009 | QoS parameters for GBR flows in NG-RAN Bearer | STRUCTURE | | | GBR QoS Flow Information IE in TS 37.483 [21] Clause 9.3.1.30 | +| 15010 | >Maximum Flow Bit Rate Downlink | ELEMENT | FALSE | Bit Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 15011 | >Guaranteed Flow Bit Rate Downlink | ELEMENT | FALSE | Bit Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 15012 | >Maximum Packet Loss Rate Downlink | ELEMENT | FALSE | Packet Loss Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 15013 | Maximum Flow Bit Rate Uplink | ELEMENT | FALSE | Bit Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 15014 | >Guaranteed Flow Bit Rate Uplink | ELEMENT | FALSE | Bit Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 15015 | >Maximum Packet Loss Rate Uplink | ELEMENT | FALSE | Packet Loss Rate IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 15016 | QoS Monitoring Enable Request | ELEMENT | FALSE | QoS Monitoring Request IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 15017 | QoS Monitoring Reporting Frequency | ELEMENT | FALSE | QoS Monitoring Reporting Frequency IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 15018 | QoS Monitoring Disabled | ELEMENT | FALSE | QoS Monitoring Disabled IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 15019 | Reflective QoS Mapping | ELEMENT | FALSE | RDI IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 15020 | Redundant QoS Flow Indicator | ELEMENT | FALSE | Redundant QoS Flow Indicator IE in TS 37.483 [21] Clause 9.3.1.74 | | +| 15021 | Averaging Window | ELEMENT | FALSE | Averaging Window IE in TS 37.483 [21] Clause 9.3.1.49 | | +| 15022 | Delay Critical | ELEMENT | FALSE | Delay Critical IE in TS 37.483 [21] Clause | | + +| | | | | | | +|-------|---------------------------|---------|-------|-----------------------------------------------------------------------|--| +| | | | | 9.3.1.28 | | +| 15023 | Maximum Data Burst Volume | ELEMENT | FALSE | <i>Maximum Data Burst Volume IE in TS 37.483 [21] Clause 9.3.1.50</i> | | + +### 8.1.1.7 Cell Group + +The following RAN Parameters are associated with the NR cell group item. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-------------------|--------------------------|----------|---------------------------------------------------------------|-----------------------| +| 15502 | UL Configuration | ELEMENT | FALSE | <i>UL Configuration IE in TS 37.483 [21] Clause 9.3.1.11</i> | | +| 15503 | RAT Type | ELEMENT | FALSE | <i>RAT Type IE in TS 37.483 [21] Clause 9.3.1.11</i> | | +| 15504 | Number of Tunnels | ELEMENT | FALSE | <i>Number of Tunnels IE in TS 37.483 [21] Clause 9.3.1.11</i> | | + +### 8.1.1.8 L2 Bearer State Variables + +The following RAN Parameters are associated with UE-specific L2 bearer state variables across PDCP, RLC layers. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-------------------------|--------------------------|----------|----------------------------------|----------------------------------------------------------------------------------------------------------------------------------| +| 16001 | PDCP State Variables | STRUCTURE | | | PDCP State Variables defined in TS 38.323 [24] clause 7.1. LCID indicates logical channel ID, to pinpoint which PDCP entity. | +| 16002 | >LCID | ELEMENT | TRUE | INTEGER (0.. 63) | | +| 16003 | >TX_Next | ELEMENT | FALSE | INTEGER (0.. 2 <sup>32</sup> -1) | | +| 16004 | >RX_Next | ELEMENT | FALSE | INTEGER (0.. 2 <sup>32</sup> -1) | | +| 16005 | >RX_Deliv | ELEMENT | FALSE | INTEGER (0.. 2 <sup>32</sup> -1) | | +| 16006 | >RX_Reord | ELEMENT | FALSE | INTEGER (0.. 2 <sup>32</sup> -1) | | +| 16010 | RLC UM State Variables | STRUCTURE | | | RLC UM State Variables defined in TS 38.322 [25] clause 7.1. LCID indicates logical channel ID, to pinpoint which RLC UM entity. | +| 16011 | >LCID | ELEMENT | TRUE | INTEGER (0.. 63) | | +| 16012 | >TX_Next | ELEMENT | FALSE | INTEGER (0.. 4095) | | +| 16013 | >RX_Next_Reassembly | ELEMENT | FALSE | INTEGER (0.. 4095) | | +| 16014 | >RX_Timer_Trigger | ELEMENT | FALSE | INTEGER (0.. 4095) | | +| 16015 | >RX_Next_Highest | ELEMENT | FALSE | INTEGER (0.. 4095) | | +| 16020 | RLC AM State Variables | STRUCTURE | | | RLC AM State Variables defined in TS 38.322 [25] clause 7.1. LCID indicates logical channel ID, to pinpoint which RLC AM entity. | +| 16021 | >LCID | ELEMENT | TRUE | INTEGER (0.. 63) | | +| 16022 | >TX_Next_Ack | ELEMENT | FALSE | INTEGER (0.. 262143) | | +| 16023 | >TX_Next | ELEMENT | FALSE | INTEGER (0.. 262143) | | +| 16024 | >POLL_SN | ELEMENT | FALSE | INTEGER (0.. 262143) | | +| 16025 | >RX_Next | ELEMENT | FALSE | INTEGER (0.. 262143) | | +| 16026 | >RX_Next_Status_Trigger | ELEMENT | FALSE | INTEGER (0.. 262143) | | +| 16027 | >RX_Highest_Status | ELEMENT | FALSE | INTEGER (0.. 262143) | | +| 16028 | >RX_Next_Highest | ELEMENT | FALSE | INTEGER (0.. 262143) | | + +### 8.1.1.9 E-RAB QoS Parameters + +The following RAN Parameters are associated with E-RAB QoS. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-------------------------------------|--------------------------|----------|--------------------------------------------------------------|-----------------------------------------------------------------------| +| 16201 | QCI | ELEMENT | FALSE | QCI IE in TS 36.423 [17] Clause 9.2.9 | | +| 16202 | Allocation and Retention Priority | STRUCTURE | | | Allocation and Retention Priority IE in TS 36.423 [17] Clause 9.2.31 | +| 16203 | >Priority Level | ELEMENT | FALSE | Priority Level IE in TS 36.423 [17] Clause 9.2.31 | | +| 16204 | >Pre-emption Capability | ELEMENT | FALSE | Pre-emption Capability IE in TS 36.423 [17] Clause 9.2.31 | | +| 16205 | >Pre-emption Vulnerability | ELEMENT | FALSE | Pre-emption Vulnerability IE in TS 36.423 [17] Clause 9.2.31 | | +| 16206 | GBR QoS Information | STRUCTURE | | | GBR QoS Information IE in TS 36.423 [17] Clause 9.2.9 | +| 16207 | >E-RAB Maximum Bit Rate Downlink | ELEMENT | FALSE | Bit Rate IE in TS 36.423 [17] Clause 9.2.11 | E-RAB Maximum Bit Rate Downlink IE in TS 36.423 [17] Clause 9.2.10 | +| 16208 | >E-RAB Maximum Bit Rate Uplink | ELEMENT | FALSE | Bit Rate IE in TS 36.423 [17] Clause 9.2.11 | E-RAB Maximum Bit Rate Uplink IE in TS 36.423 [17] Clause 9.2.10 | +| 16209 | >E-RAB Guaranteed Bit Rate Downlink | ELEMENT | FALSE | Bit Rate IE in TS 36.423 [17] Clause 9.2.11 | E-RAB Guaranteed Bit Rate Downlink IE in TS 36.423 [17] Clause 9.2.10 | +| 16210 | >E-RAB Guaranteed Bit Rate Downlink | ELEMENT | FALSE | Bit Rate IE in TS 36.423 [17] Clause 9.2.11 | E-RAB Guaranteed Bit Rate Downlink IE in TS 36.423 [17] Clause 9.2.10 | +| 16211 | Downlink Maximum Packet Loss Rate | ELEMENT | FALSE | Packet Loss Rate IE in TS 36.423 [17] Clause 9.2.124 | Downlink Maximum Packet Loss Rate IE in TS 36.423 [17] Clause 9.2.10 | +| 16212 | Uplink Maximum Packet Loss Rate | ELEMENT | FALSE | Packet Loss Rate IE in TS 36.423 [17] Clause 9.2.124 | Uplink Maximum Packet Loss Rate IE in TS 36.423 [17] Clause 9.2.10 | + +### 8.1.1.10 Connectivity and Mobility Event thresholds + +The following RAN Parameters are associated with connectivity and mobility event thresholds, mainly related to A1, A2, A3, A4, A5, A6 events and inter-RAT B1 and B2 events. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------|--------------------------|----------|----------------------------------------|--------------------------------------------------------| +| 16500 | Event AN Trigger Config | STRUCTURE | | | <i>EventTriggerConfig</i> IE in TS 38.331 [22] | +| 16501 | >CHOICE AN Event | STRUCTURE | | | <i>eventId</i> IE in TS 38.331 [22] | +| 16502 | >>A1 Event | STRUCTURE | | | <i>EventA1</i> IE in TS 38.331 [22] | +| 16503 | >>>A1-Threshold | STRUCTURE | | 8.1.1.3 | | +| 16504 | >>>Hysteresis | ELEMENT | FALSE | <i>Hysteresis</i> IE in TS 38.331 [22] | | +| 16505 | >>RS-Type | ELEMENT | FALSE | <i>rsType</i> IE in TS 38.331 [22] | | +| 16506 | >>A2 Event | STRUCTURE | | | <i>EventA2</i> IE in TS 38.331 [22] | +| 16507 | >>>A2-Threshold | STRUCTURE | | 8.1.1.3 | | +| 16508 | >>>Hysteresis | ELEMENT | FALSE | <i>Hysteresis</i> IE in TS 38.331 [22] | | +| 16509 | >>>RS-Type | ELEMENT | FALSE | <i>rsType</i> IE in TS 38.331 [22] | | +| 16510 | >>A3 Event | STRUCTURE | | | <i>EventA3</i> IE in TS 38.331 [22] | +| 16511 | >>>A3-Offset | STRUCTURE | | 8.1.1.3 | | +| 16512 | >>>Hysteresis | ELEMENT | FALSE | <i>Hysteresis</i> IE in TS 38.331 [22] | | +| 16513 | >>>RS-Type | ELEMENT | FALSE | <i>rsType</i> IE in TS 38.331 [22] | | +| 16514 | >>A4 Event | STRUCTURE | | | <i>EventA4</i> IE in TS 38.331 [22] | +| 16515 | >>>A4-Threshold | STRUCTURE | | 8.1.1.3 | | +| 16516 | >>>Hysteresis | ELEMENT | FALSE | <i>Hysteresis</i> IE in TS 38.331 [22] | | +| 16517 | >>>RS-Type | ELEMENT | FALSE | <i>rsType</i> IE in TS 38.331 [22] | | +| 16518 | >>A5 Event | STRUCTURE | | | <i>EventA5</i> IE in TS 38.331 [22] | +| 16519 | >>>A5-Threshold1 | STRUCTURE | | 8.1.1.3 | | +| 16520 | >>>A5-Threshold2 | STRUCTURE | | 8.1.1.3 | | +| 16521 | >>>Hysteresis | ELEMENT | FALSE | <i>Hysteresis</i> IE in TS 38.331 [22] | | +| 16522 | >>>RS-Type | ELEMENT | FALSE | <i>rsType</i> IE in TS 38.331 [22] | | +| 16523 | >>A6 Event | STRUCTURE | | | <i>EventA6</i> IE in TS 38.331 [22] | +| 16524 | >>>A6-Offset | STRUCTURE | | 8.1.1.3 | | +| 16525 | >>>Hysteresis | ELEMENT | FALSE | <i>Hysteresis</i> IE in TS 38.331 [22] | | +| 16526 | >>>RS-Type | ELEMENT | FALSE | <i>rsType</i> IE in TS 38.331 [22] | | +| 16550 | Event Trigger Config Inter RAT | STRUCTURE | | | <i>EventTriggerConfigInterRAT</i> IE in TS 38.331 [22] | +| 16551 | >CHOICE Inter-RAT Event | STRUCTURE | | | <i>eventId</i> IE in TS 38.331 [22] | +| 16552 | >>B1 Event | STRUCTURE | | | <i>eventB1</i> IE in TS 38.331 [22] | +| 16553 | >>>B1-Threshold | STRUCTURE | | 8.1.1.3 | | +| 16554 | >>>Hysteresis | ELEMENT | FALSE | <i>Hysteresis</i> IE in TS 38.331 [22] | | + +| | | | | | | +|-------|-----------------------|-----------|-------|----------------------------------------|-------------------------------------| +| 16555 | >>>RS-Type | ELEMENT | FALSE | <i>rsType</i> IE in TS 38.331 [22] | | +| 16556 | >>B2 Event | STRUCTURE | | | <i>eventB2</i> IE in TS 38.331 [22] | +| 16557 | >>>B2-Threshold-NR | STRUCTURE | | 8.1.1.3 | | +| 16558 | >>>B2-Threshold-EUTRA | STRUCTURE | | 8.1.1.3 | | +| 16559 | >>>Hysteresis | ELEMENT | FALSE | <i>Hysteresis</i> IE in TS 38.331 [22] | | +| 16560 | >>>RS-Type | ELEMENT | FALSE | <i>rsType</i> IE in TS 38.331 [22] | | + +### 8.1.1.11 E2 Node + +The following RAN Parameters are associated with the E2 node. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------------------|--------------------------|----------|-----------------------------------------------------------------------|--------------------------------------------------------------------| +| 17001 | CHOICE E2 Node Component Type | STRUCTURE | | | O-RAN WG3 E2AP Clause 9.2.26 | +| 17010 | >NG-RAN gNB | STRUCTURE | | | O-RAN WG3 E2AP Clause 9.2.27 | +| 17011 | >>Global gNB ID | STRUCTURE | | | TS 38.413 [11] Clause 9.3.1.6 | +| 17012 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.413 [11] Clause 9.3.3.5 | | +| 17013 | >>>CHOICE <i>gNB ID</i> | STRUCTURE | | | <i>gNB ID</i> IE in TS 38.413 [11] Clause 9.3.1.6 | +| 17014 | >>>> <i>gNB ID</i> | STRUCTURE | | | <i>gNB ID</i> IE in TS 38.413 [11] Clause 9.3.1.6 | +| 17015 | >>>>>gNB ID | ELEMENT | FALSE | <i>gNB ID</i> IE in TS 38.413 [11] Clause 9.3.1.6 | | +| 17016 | >>List of NR served cells | LIST | | | <i>List of Served Cells NR</i> IE in TS 38.423 [15] Clause 9.1.3.1 | +| 17017 | >>>Served NR cell item | STRUCTURE | | | Individual cell item in the <i>List of Served Cells NR</i> | +| 17028 | >>>>Served NR cell | STRUCTURE | | <i>NR Cell</i> IE in 8.1.1.1 | | +| 17018 | >>Count of list of NR served cells | ELEMENT | FALSE | INTEGER (1..16384) | | +| 17019 | >>List of NR neighbour cells | LIST | | | <i>Neighbour Information</i> IE in TS 38.423 [15] Clause 9.2.2.13 | +| 17020 | >>>NR neighbour cell item | STRUCTURE | | | Individual cell item in the <i>Neighbor Information</i> IE NR | +| 17031 | >>>>Neighbour NR cell | STRUCTURE | | <i>NR Cell</i> IE in 8.1.1.1 | | +| 17021 | >>Number of RRC connections | ELEMENT | FALSE | <i>Number of RRC connections</i> IE in TS 38.423 [15] Clause 9.2.2.57 | | +| 17022 | >>gNB Performance Measurements | STRUCTURE | | 8.1.1.15 | | +| 17050 | >en-gNB | STRUCTURE | | | O-RAN WG3 E2AP Clause 9.2.27 | +| 17051 | >>Global en-gNB ID | STRUCTURE | | | TS 36.423 [17] Clause 9.2.112 | +| 17052 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 36.423 [17] | | + +| | | | | | | +|-------|------------------------------------|-----------|-------|------------------------------------------------------------|--------------------------------------------------------------------| +| | | | | Clause 9.2.4 | | +| 17053 | >>>CHOICE <i>en-gNB ID</i> | STRUCTURE | | <i>en-gNB ID</i> IE in TS 36.423 [17] Clause 9.2.112 | | +| 17054 | >>>> <i>en-gNB ID</i> | STRUCTURE | | <i>en-gNB ID</i> IE in TS 36.423 [17] Clause 9.2.112 | | +| 17055 | >>>>> <i>en-gNB ID</i> | ELEMENT | FALSE | <i>en-gNB ID</i> IE in TS 36.423 [17] Clause 9.2.112 | | +| 17056 | >>List of served NR cells | LIST | | | <i>List of Served Cells NR</i> IE in TS 38.423 [15] Clause 9.1.3.1 | +| 17057 | >>>Served NR cell item | STRUCTURE | | | Individual cell item in the <i>List of Served Cells NR</i> IE | +| 17068 | >>>>Served NR cell | STRUCTURE | | <i>NR Cell</i> IE in 8.1.1.1 | | +| 17058 | >>Count of list of NR served cells | ELEMENT | FALSE | INTEGER (1..16384) | | +| 17059 | >>List of NR neighbour cells | LIST | | | <i>Neighbour Information</i> IE in TS 38.423 [15] Clause 9.2.2.13 | +| 17060 | >>>NR neighbour cell item | STRUCTURE | | | Individual cell item in <i>Neighbour Information</i> IE | +| 17065 | >>>>NR neighbour cell | STRUCTURE | | <i>NR Cell</i> IE in 8.1.1.1 | | +| 17061 | >>gNB Performance Measurements | STRUCTURE | | 8.1.1.15 | <i>gNB Measurements</i> IE in Sec 8.1.1.15 | +| 17070 | >ng-eNB | STRUCTURE | | | O-RAN WG3 E2AP Clause 9.2.27 | +| 17071 | >>ng-eNB ID | STRUCTURE | | | <i>ng-eNB ID</i> IE in TS 38.413 [11] Clause 9.2.2.2 | +| 17072 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.413 [11] Clause 9.3.1.6 | | +| 17073 | >>>CHOICE <i>ng-eNB ID</i> | STRUCTURE | | | <i>Ng-eNB ID</i> IE in TS 38.413 [11] Clause 9.2.2.2 | +| 17074 | >>>>Macro <i>ng-eNB ID</i> | STRUCTURE | | | <i>Macro ng-eNB ID</i> IE in TS 38.413 [11] Clause 9.2.2.2 | +| 17075 | >>>>>Macro <i>ng-eNB ID</i> | ELEMENT | FALSE | <i>Macro ng-eNB ID</i> IE in TS 38.413 [11] Clause 9.2.2.2 | | +| 17076 | >>>>Short Macro <i>ng-eNB ID</i> | STRUCTURE | | | <i>Short Macro ng-eNB ID</i> IE in TS 38.413 | + +| | | | | | | +|-------|----------------------------------------|-----------|-------|-----------------------------------------------------------------------|--------------------------------------------------------------------------| +| | | | | | [11] Clause 9.2.2.2 | +| 17077 | >>>>>Short Macro <i>ng-eNB ID</i> | ELEMENT | FALSE | <i>Short Macro ng-eNB ID IE</i> in TS 38.413 [11] Clause 9.2.2.2 | | +| 17078 | >>>>Long Macro <i>ng-eNB ID</i> | STRUCTURE | | | <i>Long Macro ng-eNB ID IE</i> in TS 38.413 [11] Clause 9.2.2.2 | +| 17079 | >>>>>Long Macro <i>ng-eNB ID</i> | ELEMENT | FALSE | <i>Long Macro ng-eNB ID IE</i> in TS 38.413 [11] Clause 9.2.2.2 | | +| 17080 | >>List of E-UTRA served cells | LIST | | | <i>List of Served Cells E-UTRA IE</i> in TS 38.423 [15] Clause 9.1.3.1 | +| 17081 | >>>Served E-UTRA cell item | STRUCTURE | | | Individual cell item in <i>List of Served Cells E-UTRA IE</i> | +| 17092 | >>>>Served E-UTRA cell | STRUCTURE | | 8.1.1.2 | | +| 17082 | >>Count of list of E-UTRA served cells | ELEMENT | FALSE | INTEGER (0..16384) | | +| 17083 | >>List of E-UTRA neighbour cells | LIST | | | <i>Neighbour Information E-UTRA IE</i> in TS 38.423 [15] Clause 9.2.2.14 | +| 17084 | >>>E-UTRA neighbour cell item | STRUCTURE | | | Individual cell item in <i>Neighbour Information E-UTRA IE</i> | +| 17095 | >>>>E-UTRA neighbour cell | STRUCTURE | | 8.1.1.2 | | +| 17085 | >>Number of RRC connections | ELEMENT | FALSE | <i>Number of RRC connections IE</i> in TS 38.423 [15] Clause 9.2.2.57 | | +| 17086 | >>eNB Performance Measurements | STRUCTURE | | 8.1.1.18 | | +| 17100 | >NG-RAN gNB CU-CP | STRUCTURE | | | O-RAN WG3 E2AP Clause 9.2.27 | +| 17101 | >>Global gNB CU-CP ID | STRUCTURE | | | TS 38.413 [11] Clause 9.3.1.6 | +| 17102 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity IE</i> in TS 38.413 [11] Clause 9.3.3.5 | | +| 17103 | >>>CHOICE <i>gNB ID</i> | STRUCTURE | | | <i>gNB ID IE</i> in TS 38.413 [11] Clause 9.3.1.6 | +| 17104 | >>>> <i>gNB ID</i> | STRUCTURE | | | <i>gNB ID IE</i> in TS 38.413 [11] Clause 9.3.1.6 | +| 17105 | >>>>>gNB ID | ELEMENT | FALSE | <i>gNB ID IE</i> in TS 38.413 [11] Clause 9.3.1.6 | | +| 17107 | >>List of activated NR cells | LIST | | | <i>Cells to be</i> | + +| | | | | | | +|-------|------------------------------------|-----------|-------|---------------------------------------------------|-----------------------------------------------------------------------------| +| | | | | | <i>Activated List IE in TS 38.473 [19] Clause 9.2.1.10</i> | +| 17108 | >>>NR cell item | STRUCTURE | | | <i>Cells to be Activated Item IE in TS 38.473 [19] Clause 9.2.1.10</i> | +| 17109 | >>>>NR cell | STRUCTURE | | NR Cell IE in 8.1.1.1 | | +| 17110 | >>>>Available PLMN List | LIST | | | <i>Available PLMN List IE in TS 38.473 [19] Clause 9.2.1.10</i> | +| 17111 | >>>>>PLMN Item | STRUCTURE | | | <i>Available PLMN Item IEs IE in TS 38.473 [19] Clause 9.3.1.65</i> | +| 17112 | >>>>>>PLMN ID | ELEMENT | FALSE | PLMN Identity IE in TS 38.413 [11] Clause 9.3.3.5 | | +| 17113 | >>List of de-activated NR cells | LIST | | | <i>Cells to be Deactivated List IE in TS 38.473 [19] Clause 9.2.1.10</i> | +| 17114 | >>>NR cell item | STRUCTURE | | | Individual cell item in <i>Cells to be Deactivated List IE</i> | +| 17515 | >>>>NR cell | STRUCTURE | | NR Cell IE in 8.1.1.1 | | +| 17115 | >>List of barred NR cells | LIST | | | <i>Cells to be barred List IE in TS 38.473 [19] Clause 9.2.1.10</i> | +| 17116 | >>>NR cell item | STRUCTURE | | | Individual cell item in <i>Cells to be barred List IE</i> | +| 17517 | >>>>NR cell | STRUCTURE | | NR Cell IE in 8.1.1.1 | | +| 17117 | >>Count of list of NR served cells | ELEMENT | FALSE | INTEGER (0..16384) | | +| 17118 | >>List of NR neighbour cells | LIST | | | <i>Neighbour Cell Information List IE in TS 38.473 [19] Clause 9.2.1.10</i> | +| 17119 | >>>NR neighbour cell item | STRUCTURE | | | Individual Cell Item in <i>Neighbour Cell Information List IE</i> | +| 17520 | >>>>NR neighbour cell | STRUCTURE | | NR Cell IE in | | + +| | | | | | | +|-------|--------------------------------------|-----------|-------|----------------------------------------------------------------------------------|--------------------------------------------------------------------| +| 17120 | >>Number of RRC connected UEs | ELEMENT | FALSE | 8.1.1.1<br><i>Number of RRC connections</i> IE in TS 38.423 [15] Clause 9.2.2.57 | | +| 17121 | >>gNB CU-CP Performance Measurements | STRUCTURE | | 8.1.1.12 | | +| 17130 | >NG-RAN gNB DU | STRUCTURE | | | O-RAN WG3 E2AP Clause 9.2.27 | +| 17132 | >>gNB-DU ID | ELEMENT | FALSE | <i>gNB-DU ID</i> IE in TS 38.473 [19] Clause 9.3.1.9 | | +| 17133 | >>List of NR served cells | LIST | | | <i>List of Served Cells NR</i> IE in TS 38.423 [15] Clause 9.1.3.1 | +| 17134 | >>>Served NR cell item | STRUCTURE | | | Individual cell item in <i>List of Served Cells NR</i> IE | +| 17535 | >>>>Served NR cell | STRUCTURE | | <i>NR Cell</i> IE in 8.1.1.1 | | +| 17135 | >>gNB DU Measurements | STRUCTURE | | 8.1.1.14 | | +| 17140 | >NG-RAN gNB CU-UP | STRUCTURE | | | O-RAN WG3 E2AP Clause 9.2.27 | +| 17141 | >>gNB CU-UP ID | ELEMENT | TRUE | <i>gNB-CU-UP ID</i> IE in TS 37.483 [21] Clause 9.3.1.15 | | +| 17142 | >>gNB CU-UP Capacity | ELEMENT | FALSE | <i>gNB-CU-UP Capacity</i> IE in TS 37.483 [21] Clause 9.3.1.56 | | +| 17143 | >>gNB CU-UP Performance Measurements | STRUCTURE | | 8.1.1.13 | | +| 17150 | >eNB | STRUCTURE | | | O-RAN WG3 E2AP Clause 9.2.27 | +| 17151 | >>eNB ID | STRUCTURE | | | <i>eNB ID</i> IE TS 36.423 [17] Clause 9.2.2.2 | +| 17152 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 36.423 [17] Clause 9.2.4 | | +| 17153 | >>>CHOICE <i>eNB ID</i> | STRUCTURE | | | <i>Global eNB ID</i> IE in TS 36.423 [17] Clause 9.2.22 | +| 17154 | >>>>Macro eNB ID | STRUCTURE | | | <i>Macro eNB ID</i> IE in TS 36.423 [17] Clause 9.2.22 | +| 17155 | >>>>>Macro eNB ID | ELEMENT | FALSE | <i>Macro eNB ID</i> IE in TS 36.423 [17] Clause 9.2.22 | | +| 17156 | >>>>Home eNB ID | STRUCTURE | | | <i>Home eNB ID</i> IE in TS 36.423 [17] Clause 9.2.22 | +| 17157 | >>>>>Home eNB ID | ELEMENT | FALSE | <i>Home eNB ID</i> IE in TS 36.423 [17] Clause 9.2.22 | | +| 17158 | >>>>Short Macro eNB ID | STRUCTURE | | | <i>Short Macro</i> | + +| | | | | | | +|-------|----------------------------------------|-----------|-------|----------------------------------------------------------------|-------------------------------------------------------------------| +| | | | | | eNB ID IE in TS 36.423 [17] Clause 9.2.22 | +| 17159 | >>>>>Short Macro eNB ID | ELEMENT | FALSE | Short Macro eNB ID IE in TS 36.423 [17] Clause 9.2.22 | | +| 17160 | >>>>Long Macro eNB ID | STRUCTURE | | | Long Macro eNB ID IE in TS 36.423 [17] Clause 9.2.22 | +| 17161 | >>>>>Long Macro eNB ID | ELEMENT | FALSE | Long Macro eNB ID IE in TS 36.423 [17] Clause 9.2.22 | | +| 17162 | >>List of E-UTRA served cells | LIST | | | List of Served Cells E-UTRA IE in TS 38.423 [15] Clause 9.1.3.1 | +| 17163 | >>>Served E-UTRA cell item | STRUCTURE | | | Individual cell item in List of Served Cells E-UTRA IE | +| 17564 | >>>>Served E-UTRA cell | STRUCTURE | | 8.1.1.2 | | +| 17164 | >>Count of list of E-UTRA served cells | ELEMENT | FALSE | INTEGER (0..16384) | | +| 17165 | >>List of E-UTRA neighbour cells | LIST | | | Neighbour Information E-UTRA IE in TS 38.423 [15] Clause 9.2.2.14 | +| 17166 | >>>E-UTRA neighbour cell item | STRUCTURE | | | Individual cell item in Neighbour Information E-UTRA IE | +| 17567 | >>>>E-UTRA neighbour cell | STRUCTURE | | 8.1.1.2 | | +| 17167 | >>Number of RRC connected UEs | ELEMENT | FALSE | Number of RRC connections IE in TS 38.423 [15] Clause 9.2.2.57 | | +| 17168 | >>List of NR neighbour cells | LIST | | | Neighbour Information IE in TS 38.423 [15] Clause 9.2.2.13 | +| 17169 | >>>NR neighbour cell item | STRUCTURE | | | Individual cell item in Neighbour Information IE | +| 17570 | >>>>NR neighbour cell | STRUCTURE | | 8.1.1.1 | | +| 17170 | >>eNB Performance Measurements | STRUCTURE | | 8.1.1.18 | | +| 17200 | TAI Support List | LIST | | | TAI Support List IE in TS 38.423 [15] Clause 9.2.3.20 | +| 17201 | >TAI Support Item | STRUCTURE | | | TAI Support Item IE in TS 38.423 [15] Clause | + +| | | | | | | +|-------|------------------------------------|-----------|-------|---------------------------------------------------|------------------------------------------------------------------------| +| | | | | | 9.2.3.20 | +| 17202 | >>TAC | ELEMENT | FALSE | TAC IE in TS 38.423 [15] Clause 9.2.2.5 | | +| 17203 | >>List of Broadcast PLMNs | LIST | | | <i>Broadcast PLMNs IE in TS 38.423 [15] Clause 9.2.3.20</i> | +| 17204 | >>>Broadcast PLMN Item | STRUCTURE | | | <i>Broadcast PLMNs IE in TS 38.423 [15] Clause 9.2.3.20</i> | +| 17205 | >>>PLMN Identity | ELEMENT | FALSE | PLMN Identity IE in TS 38.413 [11] Clause 9.3.3.5 | | +| 17206 | >>>TAI Slice Support List | LIST | | | <i>TAI Slice Support List IE in TS 38.423 [15] Clause 9.2.3.20</i> | +| 17207 | >>>>Slice Support Item | STRUCTURE | | | <i>Slice Support Item IE in TS 38.423 [15] Clause 9.2.3.20</i> | +| 17208 | >>>>>S-NSSAI | STRUCTURE | | | <i>S-NSSAI IE in TS 38.473 [19] Clause 9.3.1.38</i> | +| 17209 | >>>>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19] Clause 9.3.1.38 | | +| 17210 | >>>>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19] Clause 9.3.1.38 | | +| 17211 | >>>Count of TAI Slice Support List | ELEMENT | FALSE | INTEGER (0..1024) | | +| 17212 | >>>NR CGI Support List | LIST | | | <i>List of Served Cells NR IE in TS 38.423 [15] Clause 9.1.3.1</i> | +| 17213 | >>>>NR CGI Cell Support Item | STRUCTURE | | | <i>Individual cell item in List of Served Cells NR IE</i> | +| 17614 | >>>>>NR CGI Cell | STRUCTURE | | NR Cell IE in 8.1.1.1 | | +| 17214 | >>>E-UTRA CGI Support List | LIST | | | <i>List of Served Cells E-UTRA IE in TS 38.423 [15] Clause 9.1.3.1</i> | +| 17215 | >>>>E-UTRA CGI Cell Support Item | STRUCTURE | | | <i>Individual cell item in List of Served Cells E-UTRA IE</i> | +| 17616 | >>>>>E-UTRA CGI | STRUCTURE | | E-UTRA Cell IE in 8.1.1.2 | | +| 17216 | >>>QoS Parameters Support List | LIST | | | <i>QoS Flow List IE in TS 37.483 [21] Clause</i> | + +| | | | | | | +|-------|-----------------------------------------|-----------|-------|------------------|-----------------------------------------------------------------------| +| 17217 | >>>>QoS Parameters Support Item | STRUCTURE | | | 9.3.1.12<br><i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.12 | +| 17218 | >>>>>CHOICE QoS Parameters Support Item | STRUCTURE | | | | +| 17219 | >>>>>>NG-RAN QoS Support Item | STRUCTURE | | 8.1.1.6 | | +| 17221 | >>>>>>>E-UTRA QoS Support Item | STRUCTURE | | 8.1.1.9 | | +| 17223 | >>Count of list of broadcast PLMNs | ELEMENT | FALSE | INTEGER (0..12) | | +| 17224 | Count of TAI Support List | ELEMENT | FALSE | INTEGER (0..256) | | + +### 8.1.1.12 gNB CU-CP Measurements + +The following RAN Parameters are associated with the gNB CU-CP measurements. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------------------------|--------------------------|----------|----------------------------------------------|--------------------------------------------------| +| 18001 | Inter-gNB Handovers | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.6.1 | +| 18002 | >Number of requested handover operations | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.7.1.1 | +| 18003 | >Number of successful handover preparations | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.7.1.2 | +| 18004 | >List of failure causes in handover preparations | LIST | | 0..<maxnoofcauses> | TS 28.552 [28]<br>Sec 5.1.1.6.1.3 | +| 18005 | >>Failure Cause Item | STRUCTURE | | | | +| 18006 | >>>Failure Cause | ELEMENT | TRUE | Cause IE in TS 38.423 [15]<br>Clause 9.2.3.2 | | +| 18007 | >>Number of failed handover preparations for the cause | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.1.3 | +| 18008 | >Number of requested handover resource allocations | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.1.4 | +| 18009 | >Number of successful handover resource allocations | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.1.5 | +| 18010 | >List of failure causes | LIST | | 0..<maxnoofcauses> | TS 28.552 [28]<br>Sec 5.1.1.6.1.6 | +| 18011 | >>Failure Cause Item | STRUCTURE | | | | +| 18012 | >>>Failure Cause | ELEMENT | TRUE | Cause IE in TS 38.413 [11]<br>Clause 9.3.1.2 | | +| 18013 | >>>Number of failed handover resource allocations for the cause | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.1.6 | +| 18014 | >Number of requested handover executions | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.1.7 | +| 18015 | >Number of successful handover executions | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.1.8 | +| 18016 | >List of failure causes in handover execution | LIST | | 0..<maxnoofcauses> | TS 28.552 [28]<br>Sec 5.1.1.6.1.9 | +| 18017 | >>Failure cause Item | STRUCTURE | | | | +| 18018 | >>>Failure Cause | ELEMENT | TRUE | Cause IE in TS 38.423 [15]<br>Clause 9.2.3.2 | | +| 18019 | >>>Number of failed handover executions for the cause | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.1.9 | +| 18020 | >List of Slices | LIST | | 0..<maxnoofslices> | TS 28.552 [28]<br>Sec 5.1.1.6.1.10 | +| 18021 | >>Slice Item | STRUCTURE | | | | +| 18022 | >>>S-NSSAI | STRUCTURE | | | S-NSSAI/ IE in TS 38.473 [19]<br>Clause 9.3.1.38 | +| 18023 | >>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 18024 | >>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 18025 | >>>Mean Time of requested handover executions | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.1.10 | +| 18026 | >>>Max Time of requested handover executions | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.1.11 | +| 18031 | >MRO Measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.25 | +| 18032 | >>Number of too-early handovers | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.25.1 | +| 18033 | >>Number of too-late handovers | ELEMENT | FALSE | INTEGER | TS 28.552 [28] | + +| | | | | | | +|-------|----------------------------------------------------------------------------|-----------|-------|----------------------------------------------|-----------------------------------| +| | | | | | Sec 5.1.1.25.1 | +| 18034 | >>Number of wrong cell handovers | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.25.1 | +| 18051 | Intra-gNB Handovers | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3.7.1 | +| 18052 | >Number of requested handover executions | ELEMENT | FALSE | | TS 28.552 [28]<br>Sec 5.1.1.6.2.1 | +| 18053 | >Number of successful handover executions | ELEMENT | FALSE | | TS 28.552 [28]<br>Sec 5.1.1.6.2.2 | +| 18054 | List of UE Context release causes | LIST | | 0..<maxnoofcauses> | TS 28.552 [28]<br>Sec 5.1.3.5.2 | +| 18055 | >Release Cause Item | STRUCTURE | | | | +| 18056 | >>Release Cause | ELEMENT | TRUE | Cause IE in TS 38.473 [19]<br>Clause 9.3.1.2 | | +| 18057 | >>Number of UE Context Release Requests | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.5.2 | +| 18061 | >MRO Measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.25 | +| 18062 | >>Number of too-early handovers | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.25.1 | +| 18063 | >>Number of too-late handovers | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.25.1 | +| 18064 | >>Number of wrong cell handovers | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.25.1 | +| 18400 | Average normally-released call duration for 5QI 1 QoS flow | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.24.1 | +| 18071 | Distribution bins for normally-released call duration for 5QI 1 QoS flow | LIST | | 0..<maxnoofbins> | TS 28.552 [28]<br>Sec 5.1.3.8 | +| 18072 | >Distribution bin item | STRUCTURE | | | | +| 18073 | >>Call Duration Bin Value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.8 | +| 18074 | >>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.8 | +| 18450 | Average abnormally-released call duration for 5QI 1 QoS flow | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.24.2 | +| 18075 | Distribution bins for abnormally-released call duration for 5QI 1 QoS flow | LIST | | 0..<maxnoofbins> | TS 28.552 [28]<br>Sec 5.1.3.9 | +| 18076 | >Distribution bin item | STRUCTURE | | | | +| 18077 | >>Call Duration Bin Value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.9 | +| 18078 | >>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.9 | +| 18100 | RRC connection related measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.15 | +| 18101 | >List of attempted RRC connection establishment causes | LIST | | 0..<maxnoofcauses> | TS 28.552 [28]<br>Sec 5.1.1.15.1 | +| 18102 | >>Attempted RRC connection establishment cause item | STRUCTURE | | | | +| 18103 | >>>Cause | ELEMENT | TRUE | Cause IE in TS 38.331 [22] Sec 6.2.2 | | +| 18104 | >>>Number of attempted RRC connection establishments | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.15.1 | +| 18111 | >List of successful RRC connection establishment causes | LIST | | 0..<maxnoofcauses> | TS 28.552 [28]<br>Sec 5.1.1.15.2 | +| 18112 | >>Successful RRC connection establishment cause item | STRUCTURE | | | | +| 18113 | >>>Cause | ELEMENT | TRUE | Cause IE in TS 38.331 [22] Sec 6.2.2 | | +| 18114 | >>>Number of successful RRC connection establishments | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.15.2 | +| 18121 | >Number of RRC connection re-establishment attempts | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.17.1 | + +| | | | | | | +|-------|-----------------------------------------------------------------------------|-----------|-------|-------------------------------------------------|--------------------------------------------------------| +| 18122 | >Successful number of RRC connection re-establishment with UE context | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.17.2 | +| 18123 | >Successful number of RRC connection re-establishment without UE context | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.17.3 | +| 18131 | >List of RRC connection resuming attempt causes | LIST | | 0..< <i>maxnoofcauses</i> > | TS 28.552 [28]<br>Sec 5.1.1.18.1 | +| 18132 | >>Cause item | STRUCTURE | | | | +| 18133 | >>>Cause | ELEMENT | TRUE | <i>Cause IE in TS 38.331 [22] Sec 6.2.2</i> | | +| 18134 | >>>Number of RRC connection resuming attempts | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.18.1 | +| 18141 | >List of successful RRC connection resuming causes | LIST | | 0..< <i>maxnoofcauses</i> > | TS 28.552 [28]<br>Sec 5.1.1.18.2 | +| 18142 | >>Cause item | STRUCTURE | | | | +| 18143 | >>>Cause | ELEMENT | TRUE | <i>Cause IE in TS 38.331 [22] Sec 6.2.2</i> | | +| 18144 | >>>Number of successful RRC connection resuming attempts | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.18.2 | +| 18151 | >List of causes for successful RRC connection resuming with fallback | LIST | | 0..< <i>maxnoofcauses</i> > | TS 28.552 [28]<br>Sec 5.1.1.18.3 | +| 18152 | >>Cause item | STRUCTURE | | | | +| 18153 | >>>Cause | ELEMENT | TRUE | <i>Cause IE in TS 38.331 [22] Sec 6.2.2</i> | | +| 18154 | >>>Number of successful RRC connection resuming attempts with fallback | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.18.3 | +| 18161 | >Number of RRC connection resuming processes followed by network release | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.18.4 | +| 18162 | >Number of RRC connection resuming processes followed by network suspension | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.18.5 | +| 18163 | >Mean number of RRC connections | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.4.1 | +| 18164 | >Maximum number of RRC connections | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.4.2 | +| 18165 | >Mean number of stored inactive RRC connections | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.4.3 | +| 18166 | >Maximum number of stored inactive RRC connections | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.4.4 | +| 18200 | QoS flow related measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.13 | +| 18201 | >List of QoS levels | LIST | | 0..< <i>maxnoofflows</i> > | TS 28.552 [28]<br>Sec 5.1.1.13 | +| 18202 | >>QoS level item | STRUCTURE | | | | +| 18203 | >>>CHOICE QoS level | STRUCTURE | | | | +| 18204 | >>>>5QI | ELEMENT | TRUE | <i>5QI IE in TS 38.413 [11] Clause 9.3.1.28</i> | | +| 18205 | >>>>S-NSSAI | STRUCTURE | | | <i>S-NSSAI</i> IE in TS 38.473 [19]<br>Clause 9.3.1.38 | +| 18206 | >>>>>SST | ELEMENT | TRUE | <i>SST IE in TS 38.473 [19] Clause 9.3.1.38</i> | | +| 18207 | >>>>>SD | ELEMENT | FALSE | <i>SD IE in TS 38.473 [19] Clause 9.3.1.38</i> | | +| 18210 | >>>Number of QoS flows attempted to release | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.13.1.2 | +| 18211 | >>>In-session activity time | ELEMENT | FALSE | INTEGER | TS 28.552 [28] | + +| | | | | | | +|-------|-----------------------------------------------------------------------|-----------|-------|---------------------------------------------|-------------------------------------------------| +| | | | | | Sec 5.1.1.13.2.1 | +| 18212 | >>>Number of QoS flows attempted to setup | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.13.3.1 | +| 18213 | >>>Number of QoS flows successfully established | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.13.2.1 | +| 18214 | >>>Number of QoS flows attempted to modify | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.13.4.1 | +| 18215 | >>>Number of QoS flows successfully modified | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.13.4.2 | +| 18216 | >>>Number of QoS flows failed to modify | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.13.4.3 | +| 18250 | DRB related measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.10 | +| 18251 | >List of QoS levels | LIST | | 0..<maxnoofflows> | TS 28.552 [28]<br>Sec 5.1.1.10 | +| 18252 | >>QoS level item | STRUCTURE | | | | +| 18253 | >>>CHOICE QoS level | STRUCTURE | | | | +| 18254 | >>>>5QI | ELEMENT | TRUE | 5QI IE in TS 38.413 [11]<br>Clause 9.3.1.28 | | +| 18255 | >>>>S-NSSAI | STRUCTURE | | | S-NSSAI IE in TS 38.473 [19]<br>Clause 9.3.1.38 | +| 18256 | >>>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 18257 | >>>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 18258 | >>>Number of DRBs attempted to setup | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.10.1 | +| 18259 | >>>Number of DRBs successfully setup | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.10.2 | +| 18260 | >>>Number of released active DRBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.10.3 | +| 18261 | >>>In-session activity time for DRBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.10.4 | +| 18262 | >Total number of DRBs successfully setup aggregated across QoS levels | ELEMENT | FALSE | INTEGER | | +| 18270 | PDU Session Management | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.5 | +| 18271 | >List of slices | LIST | | 0..<maxnoofslices> | TS 28.552 [28]<br>Sec 5.1.1.18.5 | +| 18272 | >>Slice Item | STRUCTURE | | | | +| 18273 | >>>S-NSSAI | STRUCTURE | | | S-NSSAI IE in TS 38.473 [19]<br>Clause 9.3.1.38 | +| 18274 | >>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 18275 | >>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 18276 | >>>Number of PDU sessions requested for setup | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.5.1 | +| 18277 | >>>Number of PDU sessions successfully setup | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.5.2 | +| 18278 | >>>Number of PDU sessions failed to setup | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.5.3 | +| 18301 | Inter-system mobility measurements | STRUCTURE | | | TS 28.552 [28] | + +| | | | | | | +|-------|---------------------------------------------------|-----------|-------|---------|-----------------------------------| +| | between 5GS and EPS | | | | Sec 5.1.1.6.3 | +| 18302 | >Number of requested HO preparations | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.3.1 | +| 18303 | >Number of successful HO preparations | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.3.2 | +| 18304 | >Number of failed HO preparations | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.3.3 | +| 18305 | >Number of requested resource allocations for HO | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.3.4 | +| 18306 | >Number of successful resource allocations for HO | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.3.5 | +| 18307 | >Number of failed resource allocations for HO | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.3.6 | +| 18308 | >Number of requested HO executions | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.3.7 | +| 18309 | >Number of successful HO executions | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.3.8 | +| 18310 | >Number of failed HO executions | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.6.3.9 | +| 18321 | >MRO measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.25 | +| 18322 | >>Number of too early handovers | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.25.2 | +| 18323 | >>Number of too late handovers | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.25.2 | +| 18324 | >>Number of unnecessary handovers | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.25.3 | +| 18325 | >>Number of ping-pong handovers | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.25.4 | + +### 8.1.1.13 gNB CU-UP Measurements + +The following RAN Parameters are associated with gNB CU-UP measurements. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------------------------|--------------------------|----------|---------------------------------------------|--------------------------------------------------| +| 19001 | Packet delay measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3.3<br>and 5.1.1.1 | +| 19002 | >List of QoS levels | LIST | | | TS 28.552 [28]<br>Sec 5.1.3.3<br>and 5.1.1.1 | +| 19003 | >>QoS level item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3.3<br>and 5.1.1.1 | +| 19004 | >>>CHOICE QoS level | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3.3<br>and 5.1.1.1 | +| 19005 | >>>>5QI | ELEMENT | TRUE | 5QI IE in TS 38.413 [11]<br>Clause 9.3.1.28 | | +| 19006 | >>>>S-NSSAI | STRUCTURE | | | S-NSSAI IE in TS 38.473 [19]<br>Clause 9.3.1.38 | +| 19007 | >>>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 19008 | >>>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 19009 | >>>PDCP re-ordering delay in the UL | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.1.5 | +| 19010 | >>>Distribution bins for DL packet delay | LIST | | 0..<maxnoofbins<br>> | TS 28.552 [28]<br>Sec 5.1.1.1.6<br>and 5.1.3.3.4 | +| 19011 | >>>>Distribution bin item | STRUCTURE | | | | +| 19012 | >>>>>DL packet delay bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.1.6<br>and 5.1.3.3.4 | +| 19013 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.1.6<br>and 5.1.3.3.4 | +| 19021 | >>>Distribution bins for UL packet delay | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.1.7 | +| 19022 | >>>>Distribution bin item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.1.7 | +| 19023 | >>>>>DL packet delay bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.1.7 | +| 19024 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.1.7 | +| 19051 | >>>UL PDCP SDU Loss Rate | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.1.1 | +| 19052 | >>>UL F1-U Packet Loss Rate | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.1.2 | +| 19053 | >>>DL PDCP SDU Drop Rate | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.2.1 | +| 19054 | >>>Average delay DL | ELEMENT | FALSE | REAL | TS 28.552 [28]<br>Sec 5.1.3.3.1 | +| 19055 | >>>Average delay DL on F1-U | ELEMENT | FALSE | REAL | TS 28.552 [28]<br>Sec 5.1.3.3.2 | +| 19056 | >>>Distribution bins for DL packet delay on F1-U | LIST | | | TS 28.552 [28]<br>Sec 5.1.3.3.5 | +| 19057 | >>>>Distribution bin item | STRUCTURE | | | | +| 19058 | >>>>>DL packet delay bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.3.5 | + +| | | | | | | +|-------|------------------------------|-----------|-------|---------------------------------------------|-------------------------------------------------| +| 19059 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.3.5 | +| 19071 | PDCP data volume Measurement | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3.6 | +| 19072 | >List of QoS levels | LIST | | | TS 28.552 [28]<br>Sec 5.1.3.6 | +| 19073 | >>QoS level item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3.6 | +| 19074 | >>>CHOICE QoS level | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3.6 | +| 19075 | >>>>5QI | ELEMENT | TRUE | 5QI IE in TS 38.413 [11]<br>Clause 9.3.1.28 | | +| 19076 | >>>>S-NSSAI | STRUCTURE | | | S-NSSAI IE in TS 38.473 [19]<br>Clause 9.3.1.38 | +| 19077 | >>>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 19078 | >>>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 19079 | >>>DL PDCP PDU Data Volume | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.6.1 | +| 19080 | >>>DL PDCP SDU Data Volume | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.3.6.2 | + +### 8.1.1.14 gNB DU Measurements + +The following RAN Parameters are associated with gNB DU measurements. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-------------------------------------------------|--------------------------|----------|-----------------------------------------------|----------------------------------------------------------------| +| 20001 | Packet delay measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3.3<br>and 5.1.1.1 | +| 20002 | >List of QoS levels | LIST | | | TS 28.552 [28]<br>Sec 5.1.3.3<br>and 5.1.1.1 | +| 20003 | >>QoS level item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3.3<br>and 5.1.1.1 | +| 20004 | >>>CHOICE QoS level | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3.3<br>and 5.1.1.1 | +| 20005 | >>>>5QI | ELEMENT | TRUE | 5QI IE in TS 38.413 [11]<br>Clause 9.3.1.28 | | +| 20006 | >>>>S-NSSAI | STRUCTURE | | | S-NSSAI IE in TS 38.473 [19]<br>Clause 9.3.1.38 | +| 20007 | >>>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 20008 | >>>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 20009 | >>>Average delay DL air-interface | ELEMENT | FALSE | REAL | TS 28.552 [28]<br>Sec 5.1.1.1 | +| 20010 | >>>Average delay UL on over-the-air interface | ELEMENT | FALSE | REAL | TS 28.552 [28]<br>Sec 5.1.1.1 | +| 20011 | >>>Average RLC packet delay in the UL | ELEMENT | FALSE | REAL | TS 28.552 [28]<br>Sec 5.1.1.1.4 | +| 20012 | >>>Distribution bins for DL air-interface delay | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.1.2 | +| 20013 | >>>>Distribution bin item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.1.2 | +| 20014 | >>>>>Bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.1.2 | +| 20015 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.1.2 | +| 20018 | List of NR cells | LIST | | | Cell-specific measurements as in TS 28.552 [28]<br>Sec 5.1.1.2 | +| 20019 | >NR Cell Item | STRUCTURE | | 8.1.1.1 | | +| 20020 | >>NR CGI | ELEMENT | TRUE | NR CGI IE in TS 38.423 [15]<br>Clause 9.2.2.7 | | +| 20021 | >>Radio Resource Utilization | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.2 | +| 20022 | >>>DL Total PRB Usage | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.2.1 | +| 20023 | >>>UL Total PRB Usage | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.2.2 | +| 20024 | >>>Distribution bins for DL Total PRB Usage | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.2.3 | +| 20025 | >>>>Distribution bin item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.2.3 | +| 20026 | >>>>>Bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.2.3 | +| 20027 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.2.3 | + +| | | | | | | +|-------|-----------------------------------------------|-----------|-------|---------------------------------------------|-------------------------------------------------| +| 20028 | >>>Distribution bins for UL Total PRB Usage | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.2.4 | +| 20029 | >>>>Distribution bin item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.2.4 | +| 20030 | >>>>>Bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.2.4 | +| 20031 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.2.4 | +| 20032 | >>>List of QoS levels | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.2.5 | +| 20033 | >>>>QoS level item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.2.5 | +| 20034 | >>>>>CHOICE QoS level | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.2.5 | +| 20035 | >>>>>>5QI | ELEMENT | TRUE | 5QI IE in TS 38.413 [11]<br>Clause 9.3.1.28 | | +| 20036 | >>>>>>S-NSSAI | STRUCTURE | | | S-NSSAI IE in TS 38.473 [19]<br>Clause 9.3.1.38 | +| 20037 | >>>>>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 20038 | >>>>>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 20039 | >>>>>DL PRB used for data traffic | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.2.5 | +| 20040 | >>>>>UL PRB used for data traffic | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.2.5 | +| 20041 | >>>DL total available PRB | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.2.6 | +| 20042 | >>>UL total available PRB | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.2.8 | +| 20051 | UE Throughput Measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.3 | +| 20052 | >List of QoS levels | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.3 | +| 20053 | >>QoS level item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.3 | +| 20054 | >>>CHOICE QoS level | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.3 | +| 20055 | >>>>5QI | ELEMENT | TRUE | 5QI IE in TS 38.413 [11]<br>Clause 9.3.1.28 | | +| 20056 | >>>>S-NSSAI | STRUCTURE | | | S-NSSAI IE in TS 38.473 [19]<br>Clause 9.3.1.38 | +| 20057 | >>>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 20058 | >>>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 20059 | >>Average DL UE throughput | ELEMENT | FALSE | REAL | TS 28.552 [28]<br>Sec 5.1.1.3.1 | +| 20060 | >>Average UL UE throughput | ELEMENT | FALSE | REAL | TS 28.552 [28]<br>Sec 5.1.1.3.3 | +| 20061 | >>Percentage of unrestricted DL UE throughput | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.3.5 | +| 20062 | >>Percentage of unrestricted UL UE throughput | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.3.6 | +| 20063 | >>Distribution bins for DL UE throughput | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.3.2 | + +| | | | | | | +|-------|------------------------------------------|-----------|-------|-----------------------------------------------|----------------------------------------------------------------| +| 20064 | >>>Distribution bin item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.3.2 | +| 20065 | >>>>Bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.3.2 | +| 20066 | >>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.3.2 | +| 20067 | >>Distribution bins for UL UE throughput | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.3.4 | +| 20068 | >>>Distribution bin item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.3.4 | +| 20069 | >>>>Bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.3.4 | +| 20070 | >>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.3.4 | +| 20098 | List of NR Cells | LIST | | | Cell-specific measurements as in TS 28.552 [28]<br>Sec 5.1.1.7 | +| 20099 | >NR Cell Item | STRUCTURE | | 8.1.1.1 | | +| 20100 | >>NR CGI | ELEMENT | TRUE | NR CG/ IE in TS 38.423 [15]<br>Clause 9.2.2.7 | | +| 20101 | >>TB-related Measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.7 | +| 20102 | >>>DL initial TBs | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.7 | +| 20103 | >>>>Total number of DL initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.1 | +| 20104 | >>>>Total number of DL QPSK initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.1 | +| 20105 | >>>>Total number of DL 16QAM initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.1 | +| 20106 | >>>>Total number of DL 64QAM initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.1 | +| 20107 | >>>UL initial TBs | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.7.6 | +| 20108 | >>>>Total number of UL initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.6 | +| 20109 | >>>>Total number of UL QPSK initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.6 | +| 20110 | >>>>Total number of UL 16QAM initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.6 | +| 20111 | >>>>Total number of UL 64QAM initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.6 | +| 20121 | >>>Initial error number of DL TBs | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.7.2 | +| 20122 | >>>>Error number of DL initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.2 | +| 20123 | >>>>Error number of DL QPSK initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.2 | +| 20124 | >>>>Error number of DL 16QAM initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.2 | +| 20125 | >>>>Error number of DL 64QAM initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.2 | +| 20126 | >>>Initial error number of UL TBs | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.7.7 | +| 20127 | >>>>Error number of UL initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.7 | +| 20128 | >>>>Error number of UL QPSK initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.7 | +| 20129 | >>>>Error number of UL 16QAM initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.7 | +| 20130 | >>>>Error number of UL 64QAM initial TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.7 | + +| | | | | | | +|-------|-------------------------------------------|-----------|-------|---------|----------------------------------| +| 20131 | >>>DL total TBs | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.7.3 | +| 20132 | >>>>Total number of DL TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.3 | +| 20133 | >>>>Total number of DL QPSK TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.3 | +| 20134 | >>>>Total number of DL 16QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.3 | +| 20135 | >>>>Total number of DL 64QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.3 | +| 20136 | >>>UL total TBs | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.7.8 | +| 20137 | >>>>Total number of UL TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.8 | +| 20138 | >>>>Total number of UL QPSK TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.8 | +| 20139 | >>>>Total number of UL 16QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.8 | +| 20140 | >>>>Total number of UL 64QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.8 | +| 20141 | >>>Total error number of DL TBs | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.7.3 | +| 20142 | >>>>Total error number of DL TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.3 | +| 20143 | >>>>Total error number of DL QPSK TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.3 | +| 20144 | >>>>Total error number of DL 16QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.3 | +| 20145 | >>>>Total error number of DL 64QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.3 | +| 20146 | >>>Total error number of UL TBs | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.7.9 | +| 20147 | >>>>Total error number of UL TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.9 | +| 20148 | >>>>Total error number of UL QPSK TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.9 | +| 20149 | >>>>Total error number of UL 16QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.9 | +| 20150 | >>>>Total error number of UL 64QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.9 | +| 20151 | >>>Residual error number of DL TBs | STRUCTURE | | | TS 28.552 [28]<br>Sec | +| 20152 | >>>>Residual error number of DL TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.5 | +| 20153 | >>>>Residual error number of DL QPSK TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.5 | +| 20154 | >>>>Residual error number of DL 16QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.5 | +| 20155 | >>>>Residual error number of DL 64QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.5 | +| 20156 | >>>Residual error number of UL TBs | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.7.10 | +| 20157 | >>>>Residual error number of UL TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.10 | +| 20158 | >>>>Residual error number of UL QPSK TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.10 | +| 20159 | >>>>Total error number of UL 16QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.10 | +| 20160 | >>>>Total error number of UL 64QAM TBs | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.7.10 | +| 20201 | >>CQI-related measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.11 | +| 20202 | >>>Distribution bins of CQI values | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.11 | +| 20203 | >>>>Distribution bin item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.11 | + +| | | | | | | +|-------|---------------------------------------------|-----------|-------|---------------------------------------------|-------------------------------------------------| +| 20204 | >>>>>Bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.11 | +| 20205 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.11 | +| 20206 | >>MCS-related measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.12 | +| 20207 | >>>Distribution bins of PDSCH MCS values | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.12.1 | +| 20208 | >>>>Distribution bin item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.12.1 | +| 20209 | >>>>>Bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.12.1 | +| 20210 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.12.1 | +| 20211 | >>>Distribution bins of PUSCH MCS values | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.12.2 | +| 20212 | >>>>Distribution bin item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.12.2 | +| 20213 | >>>>>Bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.12.2 | +| 20214 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.12.2 | +| 20251 | >>Number of active UE measurements | STRUCTURE | | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.23 | +| 20252 | >>>List of QoS levels | LIST | | | TS 28.552 [28]<br>Sec 5.1.1.23 | +| 20253 | >>>>QoS level item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.23 | +| 20254 | >>>>>CHOICE QoS level | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.1.23 | +| 20255 | >>>>>>5QI | ELEMENT | TRUE | 5QI IE in TS 38.413 [11]<br>Clause 9.3.1.28 | | +| 20256 | >>>>>>S-NSSAI | STRUCTURE | | | S-NSSAI IE in TS 38.473 [19]<br>Clause 9.3.1.38 | +| 20257 | >>>>>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 20258 | >>>>>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19]<br>Clause 9.3.1.38 | | +| 20259 | >>>>>Number of active UEs in the DL | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.23.1 | +| 20260 | >>>>>Maximum number of active UEs in the DL | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.23.2 | +| 20261 | >>>>>Number of active UEs in the UL | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.23.3 | +| 20262 | >>>>>Maximum number of active UEs in the UL | ELEMENT | FALSE | INTEGER | TS 28.552 [28]<br>Sec 5.1.1.23.4 | +| 20271 | Packet level measurements | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3 | +| 20272 | >List of QoS levels | LIST | | | TS 28.552 [28]<br>Sec 5.1.3 | +| 20273 | >>QoS level item | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3 | +| 20274 | >>>CHOICE QoS level | STRUCTURE | | | TS 28.552 [28]<br>Sec 5.1.3 | +| 20275 | >>>>5QI | ELEMENT | TRUE | 5QI IE in TS 38.413 [11]<br>Clause 9.3.1.28 | | +| 20276 | >>>>S-NSSAI | STRUCTURE | | | S-NSSAI IE in TS 38.473 [19]<br>Clause 9.3.1.38 | + +| | | | | | | +|-------|----------------------------------------------------|-----------|--------------|------------------------------------------|------------------------------| +| 20277 | >>>>>SST | ELEMENT | TRUE | SST IE in TS 38.473 [19] Clause 9.3.1.38 | | +| 20278 | >>>>>SD | ELEMENT | <b>FALSE</b> | SD IE in TS 38.473 [19] Clause 9.3.1.38 | | +| 20279 | >>>DL F1-U Packet Loss Rate | ELEMENT | FALSE | INTEGER | TS 28.552 [28] Sec 5.1.3.1.3 | +| 20280 | >>>DL RLC SDU Packet Drop Rate | ELEMENT | FALSE | INTEGER | TS 28.552 [28] Sec 5.1.3.2.2 | +| 20281 | >>>Average delay DL in gNB-DU | ELEMENT | FALSE | REAL | TS 28.552 [28] Sec 5.1.3.3.3 | +| 20282 | >>>Distribution bins of DL delay | LIST | | | TS 28.552 [28] Sec 5.1.3.3.6 | +| 20283 | >>>>Distribution bin item | STRUCTURE | | | TS 28.552 [28] Sec 5.1.3.3.6 | +| 20284 | >>>>>Bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28] Sec 5.1.3.3.6 | +| 20285 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28] Sec 5.1.1.3.6 | +| 20286 | >>>Average IP latency DL | ELEMENT | FALSE | REAL | TS 28.552 [28] Sec 5.1.3.4.2 | +| 20287 | >>>Distribution bins of DL IP latency | LIST | | | TS 28.552 [28] Sec 5.1.3.4.3 | +| 20288 | >>>>Distribution bin item | STRUCTURE | | | TS 28.552 [28] Sec 5.1.3.4.3 | +| 20289 | >>>>>Bin value | ELEMENT | FALSE | INTEGER | TS 28.552 [28] Sec 5.1.3.4.3 | +| 20290 | >>>>>Number of samples | ELEMENT | FALSE | INTEGER | TS 28.552 [28] Sec 5.1.3.4.3 | +| 20291 | Number of UE Context release requested from gNB-DU | ELEMENT | FALSE | INTEGER | TS 28.552 [28] Sec 5.1.3.5.1 | + +### 8.1.1.15 gNB Measurements + +The following RAN Parameters are associated with the gNB measurements. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------|--------------------------|----------|--------------------------|---------------------------------------------| +| 20501 | gNB CU-CP Measurements | STRUCTURE | | 8.1.1.12 | For both UE- and E2 node level measurements | +| 20502 | gNB CU-UP Measurements | STRUCTURE | | 8.1.1.13 | For both UE- and E2 node level measurements | +| 20503 | gNB DU Measurements | STRUCTURE | | 8.1.1.14 | For both UE- and E2 node level measurements | + +### 8.1.1.16 PDU Session + +The following RAN Parameters are associated with PDU session. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------------------------|--------------------------|----------|----------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------| +| 21001 | S-NSSAI | STRUCTURE | | | <i>S-NSSAI</i> IE in TS 38.473 [19] Clause 9.3.1.38 | +| 21002 | >SST | ELEMENT | TRUE | <i>SST</i> IE in TS 38.473 [19] Clause 9.3.1.38 | | +| 21003 | >SD | ELEMENT | FALSE | <i>SD</i> IE in TS 38.473 [19] Clause 9.3.1.38 | | +| 21004 | PDU Session Aggregate Maximum Bit Rate | STRUCTURE | | | <i>PDU Session Aggregate Maximum Bit Rate</i> IE in TS 38.413 [11] Clause 9.3.1.102 | +| 21005 | >PDU Session Aggregate Maximum Bit Rate Downlink | ELEMENT | FALSE | <i>PDU Session Aggregate Maximum Bit Rate Downlink</i> IE in TS 38.413 [11] Clause 9.3.1.102 | | +| 21006 | >PDU Session Aggregate Maximum Bit Rate Uplink | ELEMENT | FALSE | <i>PDU Session Aggregate Maximum Bit Rate Uplink</i> IE in TS 38.413 [11] Clause 9.3.1.102 | | +| 21008 | >Data Forwarding Not Possible | ELEMENT | FALSE | <i>Data Forwarding Not Possible</i> IE in TS 38.413 [11] Clause 9.3.1.63 | | +| 21009 | >PDU Session Type | ELEMENT | FALSE | <i>PDU Session Type</i> IE in TS 38.413 [11] Clause 9.3.1.52 | | +| 21010 | >Network Instance | ELEMENT | FALSE | <i>Network Instance</i> IE in TS 38.413 [11] Clause 9.3.1.113 | | +| 21011 | >Direct Forwarding Path Availability | ELEMENT | FALSE | <i>Direct Forwarding Path Availability</i> IE in TS 38.413 [11] Clause 9.3.1.120 | | +| 21012 | >Redundant Common Network Instance | ELEMENT | FALSE | <i>Redundant Common Network Instance</i> IE in TS 38.413 [11] Clause | | + +| | | | | | | +|-------|------------------------------------|---------|-------|--------------------------------------------------------------------------------|--| +| | | | | 9.3.1.120 | | +| 21013 | >Redundant PDU Session Information | ELEMENT | FALSE | <i>Redundant PDU Session Information</i> IE in TS 38.413 [11] Clause 9.3.1.136 | | + +#### 8.1.1.17 UE Context Information + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------|--------------------------|----------|------------------------------------------------------------|---------------------------------------------------------------------------------------------------------| +| 21501 | Master Node | STRUCTURE | | 8.1.1.11 | | +| 21502 | >gNB Measurements | STRUCTURE | | 8.1.1.15 | | +| 21503 | CHOICE Primary Cell of MCG | STRUCTURE | | | | +| 21504 | >NR Cell | STRUCTURE | | 8.1.1.1 | For NR SpCell | +| 21505 | >E-UTRA Cell | STRUCTURE | | 8.1.1.2 | For E-UTRA PCell | +| 21506 | List of Secondary Cells of MCG | LIST | | | <i>Scell To Be Setup List</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 21507 | >SCell Item | STRUCTURE | | | <i>Scell To Be Setup Item</i> IEs IE in TS 38.473 [19] clause 9.2.2.1 | +| 21508 | >>CHOICE SCell | STRUCTURE | | | | +| 21509 | >>>NR Cell | STRUCTURE | | 8.1.1.1 | For NR SCell | +| 21510 | >>>E-UTRA Cell | STRUCTURE | | 8.1.1.2 | For E-UTRA SCell | +| 21511 | Secondary Node | STRUCTURE | | 8.1.1.11 | | +| 21512 | >gNB Measurements | STRUCTURE | | 8.1.1.15 | | +| 21513 | CHOICE Primary Cell of SCG | STRUCTURE | | | <i>PSCell</i> IE as defined in TS 38.331 [22] or the structure defined in TS 38.473 [19] clause 9.2.2.1 | +| 21514 | >NR Cell | STRUCTURE | | 8.1.1.1 | | +| 21515 | >E-UTRA Cell | STRUCTURE | | 8.1.1.2 | | +| 21516 | List of Secondary Cells of SCG | LIST | | | <i>Scell To Be Setup List</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 21517 | >SCell Item | STRUCTURE | | | <i>Scell To Be Setup Item</i> IEs IE in TS 38.473 [19] clause 9.2.2.1 | +| 21518 | >>CHOICE SCell | STRUCTURE | | | | +| 21519 | >>>NR Cell | STRUCTURE | | 8.1.1.1 | | +| 21520 | >>>E-UTRA Cell | STRUCTURE | | 8.1.1.2 | | +| 21521 | List of PDU Sessions | LIST | | | <i>PDU Session Resources To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 21522 | >PDU Session Item | STRUCTURE | | | <i>PDU Session Resources To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 21543 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.413 [11] Clause 9.3.1.50 | | +| 21523 | >>PDU Session | STRUCTURE | | 8.1.1.16 | | +| 21524 | >>List of DRBs | LIST | | | <i>DRB to Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 21525 | >>>DRB Item | STRUCTURE | | | | + +| | | | | | | +|-------|-------------------------------------|-----------|-------|----------------------------------------------------------|------------------------------------------------------------------------------------| +| 21546 | >>>>DRB ID | ELEMENT | TRUE | DRB ID IE in TS 37.483 [21] clause 9.3.1.16 | | +| 21547 | >>>>DRB | STRUCTURE | | 8.1.1.5 | | +| 21526 | >>>>List of QoS flows mapped to DRB | LIST | | | QoS Flows Information To Be Setup IE in TS 37.483 [21] Clause 9.3.3.2 | +| 21527 | >>>>>QoS Flow Item | STRUCTURE | | | | +| 21548 | >>>>>QoS Flow Identifier | ELEMENT | TRUE | QoS Flow Identifier IE in TS 38.413 [11] Clause 9.3.1.51 | | +| 21549 | >>>>>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 21528 | List of Neighbour cells | LIST | | | measResultNeighCells IE in TS 38.331 [22] | +| 21529 | >Neighbour Cell Item | STRUCTURE | | | | +| 21530 | >>CHOICE Neighbour Cell | STRUCTURE | | | | +| 21531 | >>>NR Cell | STRUCTURE | | 8.1.1.1 | MeasResultNR IE in TS 38.331 [22] | +| 21532 | >>>E-UTRA Cell | STRUCTURE | | 8.1.1.2 | MeasResultEUTRA IE in TS 38.331 [22] | +| 21540 | UE Context Container | ELEMENT | FALSE | OCTET STRING | The RETRIEVE UE CONTEXT RESPONSE message content in TS 38.423 [15] clause 9.1.1.9. | +| 21541 | SRS Configuration | ELEMENT | FALSE | OCTET STRING | SRS-Config IE defined in TS 38.331 [22]. | +| 21600 | CSI Measurement Configuration | ELEMENT | FALSE | OCTET STRING | CSI-MeasConfig IE defined in TS 38.331 [22] | +| 21601 | Measurement Gap Configuration | ELEMENT | FALSE | OCTET STRING | MeasGapConfig IE defined in TS 38.331 [22] | +| 21602 | List of BWP Downlink | LIST | | | The list of all DL BWPs assigned to a specific UE | +| 21603 | >BWP Downlink Item | STRUCTURE | | | BWP-Downlink IE in TS 38.331 [22] | +| 21604 | >>BWP ID | ELEMENT | FALSE | BWP-Id IE in TS 38.331 [22] | value of 0 represents the DL Initial BWP | +| 21605 | >>BWP Downlink Common | ELEMENT | FALSE | OCTET STRING | BWP-DownlinkCommon IE in TS 38.331 [22] | +| 21606 | >>BWP Downlink Dedicated | ELEMENT | FALSE | OCTET STRING | BWP-DownlinkDedicated IE in TS 38.331 [22] | +| 21607 | List of active RLC Bearers | LIST | | | The list of active RLC bearers of a specific UE | +| 21608 | >RLC Bearer Item | STRUCTURE | | | | +| 21609 | >>Logical Channel ID | ELEMENT | FALSE | LogicalChannelIdentity IE in TS 38.331 [22] clause 6 | | +| 21610 | >>CHOICE Served Radio Bearer | | | | | +| 21611 | >>>SRB ID | ELEMENT | FALSE | SRB-Identity IE | | + +| | | | | | | +|-------|----------------------------------|---------|-------|---------------------------------------------------|------------------------------------------------------------| +| | | | | in TS 38.331 [22] clause 6 | | +| 21612 | >>>DRB ID | ELEMENT | FALSE | <i>DRB-Identity</i> IE in TS 38.331 [22] clause 6 | | +| 21613 | PDSCH Serving Cell Configuration | ELEMENT | FALSE | OCTET STRING | <i>PDSCH-ServingCellConfig</i> IE in TS 38.331 [22] | +| 21614 | DRX Configuration | ELEMENT | FALSE | OCTET STRING | <i>DRX-Config</i> IE in TS 38.331 [22] | +| 21615 | UE Capabilities | ELEMENT | FALSE | OCTET STRING | <i>UE-CapabilityRAT-ContainerList</i> IE in TS 38.331 [22] | + +### 8.1.1.18 eNB Measurements + +Editor's Note: FFS + +## 8.1.2 RAN Parameters for Call Process Breakpoint + +### 8.1.2.0 Call process type IDs + +The RAN Parameters for the Event Trigger style 2 are defined based on the following call process type. + +| Call Process Type ID | Call Process Type | RAN Parameters | +|----------------------|----------------------------------------|---------------------------| +| 1 | UE Context Management | Defined in Clause 8.1.2.1 | +| 2 | Bearer Context Management | Defined in Clause 8.1.2.2 | +| 3 | Mobility Management | Defined in Clause 8.1.2.3 | +| 4 | Multi-RAT Dual Connectivity Management | Defined in Clause 8.1.2.4 | +| 5 | Radio Resource Control Management | Defined in Clause 8.1.2.5 | +| 6 | PDU Session Management | Defined in Clause 8.1.2.6 | + +### 8.1.2.1 UE Context Management + +The RAN Parameters for the call process type of “UE Context Management” are defined as follows. + +## 8.1.2.1.1 UE Context Setup + +| RAN Parameter xID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|-------------------|---------------------------------------|--------------------------|----------|----------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 25001 | Primary Cell ID | STRUCTURE | | | This is for the primary serving cell of the UE. The structuring of this parameter is based on <i>Target Cell Global ID</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 25002 | >CHOICE <i>Primary Cell</i> | STRUCTURE | | | The primary cell could either be an NR primary cell or an LTE primary cell. The structuring is based on <i>Target Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 25003 | >>NR SpCell | STRUCTURE | | 8.1.1.1 | <i>NR Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 or <i>SpCell ID</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 25063 | >>E-UTRA PCell | STRUCTURE | | 8.1.1.2 | <i>E-UTRA Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 25004 | List of secondary cells to be setup | LIST | | | <i>Scell To Be Setup List</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 25005 | >Secondary cell to be setup Item | STRUCTURE | | | <i>Scell To Be Setup Item</i> IEs IE in TS 38.473 [19] clause 9.2.2.1 | +| 25006 | >>CHOICE Secondary cell | STRUCTURE | | | <i>Scell To Be Setup Item</i> IEs IE in TS 38.473 [19] clause 9.2.2.1 | +| 25007 | >>>NR SCell | STRUCTURE | | 8.1.1.1 | | +| 25008 | >>>E-UTRA SCell | STRUCTURE | | 8.1.1.2 | | +| 25009 | >>>Scell UL Configured | ELEMENT | FALSE | <i>Cell UL Configured</i> IE in TS 38.473 [19] clause 9.3.1.33 | | +| 25010 | Number of secondary cells to be setup | ELEMENT | FALSE | INTEGER (1..32) | Count of list of secondary cells to be setup | +| 25011 | List of DRBs for setup | LIST | | | <i>DRB to Be Setup List</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 25012 | >DRB item for setup | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 25033 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] clause 9.3.1.16 | | +| 25034 | >>CHOICE <i>DRB Type</i> | STRUCTURE | | | The individual DRB could either be an NG-RAN DRB or a E-UTRA DRB | + +| | | | | | | +|-------|-----------------------------------------|-----------|-------|----------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------| +| 25035 | >>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 25036 | >>>E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 25013 | >List of QoS flows for setup | LIST | | | This is the list of QoS flows multiplexed to an NG-RAN DRB. The structuring is based on <i>QoS Flow List IE</i> in TS 37.483 [21] Clause 9.3.1.12 | +| 25014 | >>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item IE</i> in TS 37.483 [21] Clause 9.3.1.12 | +| 25045 | >>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier IE</i> in TS 37.483 [21] Clause 9.3.1.24 | | +| 25046 | >>>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 25015 | List of PDU sessions for setup | LIST | | | <b><i>PDU Session Resource Setup Request List IE</i></b> in TS 38.413 Clause 9.2.1.1 | +| 25016 | >PDU Session Item | STRUCTURE | | | <i>PDU Session Resource Setup Item IE</i> in TS 38.413 Clause 9.2.1.1 | +| 25057 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID IE</i> in TS 38.413 [11] Clause 9.3.1.50 | | +| 25058 | >>PDU Session | STRUCTURE | | 8.1.1.16 | | +| 25017 | >>List of QoS flows for setup | LIST | | | <i>QoS Flow Setup Request Item IE</i> in TS 38.413 Clause 9.3.4.1 | +| 25018 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Setup Request Item IE</i> in TS 38.413 Clause 9.3.4.1 | +| 25019 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier IE</i> in TS 38.413 [11] Clause 9.3.1.51 | | +| 25020 | >>>>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 25021 | Number of DRBs for setup | ELEMENT | FALSE | INTEGER (0..64) | Count of list of DRBs for setup | +| 25022 | UE Aggregate Maximum Bit Rate | STRUCTURE | | | <i>UE Aggregate Maximum Bit Rate IE</i> in TS 36.423 [17] Clause 9.2.12 | +| 25023 | >UE Aggregate Maximum Bit Rate Downlink | ELEMENT | FALSE | <i>UE Aggregate Maximum Bit Rate Downlink IE</i> in TS 36.423 [17] clause 9.2.12 | | + +| | | | | | | +|-------|---------------------------------------|---------|-------|--------------------------------------------------------------------------------|--| +| 25024 | >UE Aggregate Maximum Bit Rate Uplink | ELEMENT | FALSE | <i>UE Aggregate Maximum Bit Rate Uplink IE</i> in TS 36.423 [17] clause 9.2.12 | | +|-------|---------------------------------------|---------|-------|--------------------------------------------------------------------------------|--| + +#### 8.1.2.1.2 UE Context Modification + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------------------|--------------------------|----------|--------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 25101 | Primary Cell ID | STRUCTURE | | | This is for the primary serving cell of the UE. The structuring of this parameter is based on <i>Target Cell Global ID</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 25102 | >CHOICE <i>Primary Cell</i> | STRUCTURE | | | The primary cell could either be an NR primary cell or an LTE primary cell. The structuring is based on <i>Target Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 25103 | >>NR SpCell | STRUCTURE | | 8.1.1.1 | <i>NR</i> IE in TS 38.423 [15] clause 9.2.3.25 or <i>SpCell ID</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 25104 | >>E-UTRA PCell | STRUCTURE | | 8.1.1.2 | <i>E-UTRA</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 25105 | List of secondary cells to be setup | LIST | | | <i>Scell To Be Setup List</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 25106 | >Secondary cell to be setup Item | STRUCTURE | | | <i>Scell To Be Setup Item</i> IEs IE in TS 38.473 [19] clause 9.2.2.1 | +| 25107 | >>CHOICE Secondary cell | STRUCTURE | | | <i>Scell To Be Setup Item</i> IEs IE in TS 38.473 [19] clause 9.2.2.1 | +| 25108 | >>>NR SCell | STRUCTURE | | 8.1.1.1 | | +| 25109 | >>>E-UTRA SCell | STRUCTURE | | 8.1.1.2 | | +| 25110 | >>>Scell UL Configured | ELEMENT | FALSE | <i>Cell UL Configured</i> IE in TS 38.473 [19] [Q] clause 9.3.1.33 | | +| 25111 | Number of secondary cells to be setup | ELEMENT | FALSE | INTEGER (1..32) | Count of list of secondary cells to be setup | +| 25112 | List of Scells to be removed | LIST | | | <i>SCell To Be Removed List</i> IE in TS 38.473 [19] clause 9.2.2.7 | +| 25113 | >Scell to be removed Item | STRUCTURE | | | <i>SCell to Be Removed Item</i> IEs IE in TS 38.473 [19] clause 9.2.2.7 | +| 25114 | >>CHOICE Secondary cell | STRUCTURE | | | A UE can have either NR Cells as secondary cells or E-UTRA cells as secondary cells. | +| 25115 | >>>NR SCell | STRUCTURE | | 8.1.1.1 | | + +| | | | | | | +|-------|-----------------------------------------|-----------|-------|--------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 25116 | >>>E-UTRA SCell | STRUCTURE | | 8.1.1.2 | | +| 25117 | >>>Scell UL Configured | ELEMENT | FALSE | <i>Cell UL Configured</i> IE in TS 38.473 [19] [Q] clause 9.3.1.33 | | +| 25118 | Number of secondary cells to be removed | ELEMENT | FALSE | INTEGER (1..32) | Count of list of secondary cells to be removed | +| 25119 | List of DRBs for setup | LIST | | | DRB to Be Setup List IE in TS 38.473 [19] clause 9.2.2.1 | +| 25120 | >DRB item for setup | STRUCTURE | | | DRB to Be Setup Item IE in TS 38.473 [19] clause 9.2.2.1 | +| 25161 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] clause 9.3.1.16 | | +| 25162 | >>CHOICE <i>DRB Type</i> | STRUCTURE | | | DRB could either be an NG-RAN DRB or a E-UTRA DRB | +| 25163 | >>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 25164 | >>>E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 25121 | >>List of QoS flows for setup | LIST | | | This is the list of QoS flows multiplexed to an NG-RAN DRB for setup. The structuring is based on <i>QoS Flow List</i> IE in TS 37.483 [21] Clause 9.3.1.12 | +| 25122 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.12 | +| 25166 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] Clause 9.3.1.24 | | +| 25167 | >>>>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 25123 | List of PDU sessions for setup | LIST | | | <i>PDU Session Resource Setup Request List</i> IE in TS 38.413 Clause 9.2.1.1 | +| 25124 | >PDU Session Item | STRUCTURE | | | <i>PDU Session Resource Setup Item</i> IE in TS 38.413 Clause 9.2.1.1 | +| 25175 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.413 [11] Clause 9.3.1.50 | | +| 25176 | >>PDU Session | STRUCTURE | | 8.1.1.16 | | +| 25125 | >>List of QoS flows for setup | LIST | | | <i>QoS Flow Setup Request Item</i> IE in TS 38.413 Clause 9.3.4.1 | + +| | | | | | | +|-------|---------------------------------------|-----------|------|-----------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------| +| 25126 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Setup Request Item</i> IE in TS 38.413 Clause 9.3.4.1 | +| 25177 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.413 [11] Clause 9.3.1.51 | | +| 25178 | >>>>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 25127 | List of DRBs to be modified | LIST | | | <i>DRB to Be Setup List</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 25128 | >DRB item for modification | STRUCTURE | | 8.1.1.5 | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 25129 | >>List of QoS flows remapped | LIST | | | This is the list of QoS flows remapped to an NG-RAN DRB. The structuring is based on <i>QoS Flow List</i> IE in TS 37.483 [21] Clause 9.3.1.12 | +| 25130 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.12 | +| 25181 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [12] Clause 9.3.1.24 | | +| 25182 | >>>>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 25131 | List of PDU sessions for modification | LIST | | | For modification of PDU sessions. The structuring is based on <i>PDU Session Resource Modify Request List</i> IE in TS 38.413 Clause 9.2.1.5 | +| 25132 | >PDU Session Item | STRUCTURE | | | <i>PDU Session Resource Modify Request Item</i> IE in TS 38.413 Clause 9.2.1.5 | +| 25183 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.413 [11] Clause 9.3.1.50 | | +| 25184 | >>PDU Session | STRUCTURE | | 8.1.1.16 | | +| 25133 | >>List of QoS flows remapped | LIST | | | Modified list of QoS flows within the PDU Session. Structuring is based on <i>QoS Flow Add or Modify Request List</i> IE in TS 38.413 Clause 9.3.4.3 | +| 25134 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Add or Modify Request Item</i> IE in TS 38.413 Clause 9.3.4.3 | + +| | | | | | | +|-------|-----------------------------------------|-----------|-------|---------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 25185 | >>>>QoS flow identifier | ELEMENT | TRUE | QoS Flow Identifier IE in TS 38.413 [11] Clause 9.3.1.51 | | +| 25186 | >>>>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 25135 | Number of DRBs to be modified | ELEMENT | FALSE | | Count of list of DRBs to be modified | +| 25136 | List of DRBs to be released | LIST | | | DRB To Be Released List IE in TS 38.473 [19] Clause 9.2.2.7 | +| 25137 | >DRB item for release | STRUCTURE | | | DRB To Be Released Item IE in TS 38.473 [19] Clause 9.2.2.7 | +| 25188 | >>DRB ID | ELEMENT | TRUE | DRB ID IE in TS 37.483 [21] clause 9.3.1.16 | | +| 25189 | >>CHOICE DRB Type | STRUCTURE | | | DRB could either be an NG-RAN DRB or a E-UTRA DRB | +| 25190 | >>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 25191 | >>>E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 25138 | Number of DRBs to be released | ELEMENT | FALSE | | Count of list of DRBs to be released | +| 25139 | UE Aggregate Maximum Bit Rate | STRUCTURE | | | UE Aggregate Maximum Bit Rate IE in TS 36.423 [17] Clause 9.2.12 | +| 25140 | >UE Aggregate Maximum Bit Rate Downlink | ELEMENT | FALSE | UE Aggregate Maximum Bit Rate Downlink IE in TS 36.423 [17] clause 9.2.12 | | +| 25141 | >UE Aggregate Maximum Bit Rate Uplink | ELEMENT | FALSE | UE Aggregate Maximum Bit Rate Uplink IE in TS 36.423 [17] clause 9.2.12 | | +| 25151 | Target Cell ID | STRUCTURE | | | This is for the target cell of the UE for HO. The structuring of this parameter is based on Target Cell Global ID IE in TS 38.423 [15] clause 9.2.3.25 | +| 25152 | >CHOICE Target Cell | STRUCTURE | | | The target cell could either be a target NR primary cell or a target LTE primary cell. The structuring is based on Target Cell IE in TS 38.423 [15] clause 9.2.3.25 | +| 25153 | >>Target NR SpCell | STRUCTURE | | 8.1.1.1 | NR IE in TS 38.423 [15] clause 9.2.3.25 | +| 25154 | >>Target E-UTRA PCell | STRUCTURE | | 8.1.1.2 | E-UTRA IE in TS 38.423 [15] clause 9.2.3.25 | + +### 8.1.2.1.3 UE Context Release + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------|--------------------------|----------|--------------------------|---------------------------------------------------------------------------------------| +| 25201 | List of candidate cells to be cancelled | LIST | | | <i>Candidate Cells To Be Cancelled List</i><br>IE in TS 38.473<br>[19] Clause 9.2.2.4 | +| 25202 | >Candidate cell to be cancelled Item | STRUCTURE | | | <i>Candidate Cell to be Cancelled Item</i><br>IE in TS 38.473<br>[19] Clause 9.2.2.4 | +| 25203 | >>CHOICE Candidate cell | STRUCTURE | | | <i>Candidate Cell to be Cancelled Item</i><br>IE in TS 38.473<br>[19] Clause 9.2.2.4 | +| 25204 | >>>NR SCell | STRUCTURE | | 8.1.1.1 | | +| 25205 | >>>E-UTRA SCell | STRUCTURE | | 8.1.1.2 | | + +### 8.1.2.2 Bearer Context Management + +The RAN Parameters for the call process type of “Bearer Context Management” are defined as follows. + +### 8.1.2.2.1 Bearer Context Setup + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------|--------------------------|----------|-----------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 26101 | DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] clause 9.3.1.16 | | +| 26102 | CHOICE <i>DRB Type</i> | STRUCTURE | | | DRB could either be an NG-RAN DRB or a E-UTRA DRB | +| 26103 | >NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 26104 | >E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 26105 | List of QoS Flows to be setup in DRB | LIST | | | This is the list of QoS flows multiplexed to an NG-RAN DRB for setup. The structuring is based on <i>QoS Flow List</i> IE in TS 37.483 [21] Clause 9.3.1.12 | +| 26106 | >QoS Flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] clause 9.3.1.12 | +| 26107 | >>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] clause 9.3.1.24 | | +| 26108 | >>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 26109 | Count of list of QoS Flows to be setup in DRB | ELEMENT | FALSE | INTEGER (0..64) | | +| 26110 | Cell Group List to Add | STRUCTURE | | | <i>CellGroupList</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 26111 | >Cell Group Item | STRUCTURE | | | | +| 26122 | >>Cell Group ID | ELEMENT | TRUE | <i>cellGroup</i> IE in TS 38.331 [22] Clause 6 | | +| 26123 | >>Cell Group | STRUCTURE | | 8.1.1.7 | | +| 26112 | Logical Channel ID | ELEMENT | FALSE | <i>LogicalChannelIdentity</i> IE in TS 38.331 [22] clause 6 | | +| 26113 | Channel Access Priority | ELEMENT | FALSE | <i>channelAccessPriority</i> IE in TS 38.331 [22] | | +| 26114 | L2 Bearer State Information | STRUCTURE | | 8.1.1.8 | | +| 26115 | Count of cell group list to be added | ELEMENT | FALSE | INTEGER (0..4) | | + +### 8.1.2.2.2 Bearer Context Modification + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------|--------------------------|----------|-----------------------------------------------------------------|----------------------------------------------------------------------| +| 26201 | DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] clause 9.3.1.16 | | +| 26202 | CHOICE <i>DRB Type</i> | STRUCTURE | | | DRB could either be an NG-RAN DRB or a E-UTRA DRB | +| 26203 | >NG-RAN DRB | STRUCTURE | | 8.1.1.1 | | +| 26204 | >E-UTRA DRB | STRUCTURE | | 8.1.1.2 | | +| 26205 | Logical Channel ID | ELEMENT | TRUE | <i>LogicalChannelIdentity</i> IE in TS 38.331 [22] clause 6 | | +| 26206 | CHOICE RLC-Config | STRUCTURE | | | <i>RLC-Config</i> IE in TS 38.331 [22] | +| 26207 | >AM | STRUCTURE | | | <i>am</i> IE in TS 38.331 [22] | +| 26208 | >>UL AM RLC | STRUCTURE | | | <i>ul-AM-RLC</i> IE in TS 38.331 [22] | +| 26209 | >>>Poll Retransmit | ELEMENT | FALSE | <i>t-PollRetransmit</i> IE in TS 38.331 [22] | | +| 26210 | >>>Max Retransmission Threshold | ELEMENT | FALSE | <i>maxRetxThreshold</i> IE in TS 38.331 [22] | | +| 26211 | >>>Poll PDU | ELEMENT | FALSE | <i>pollPDU</i> IE in TS 38.331 [22] | | +| 26212 | >>>Poll Byte | ELEMENT | FALSE | <i>pollByte</i> IE in TS 38.331 [22] | | +| 26213 | >>DL AM RLC | STRUCTURE | | | <i>dl-AM-RLC</i> IE in TS 38.331 [22] | +| 26214 | >>>Reassembly | ELEMENT | FALSE | <i>t-Reassembly</i> IE in TS 38.331 [22] | | +| 26215 | >>>Status Prohibit | ELEMENT | FALSE | <i>t-StatusProhibit</i> IE in TS 38.331 [22] | | +| 26216 | >UM Bi-directional | STRUCTURE | | | <i>um-Bi-Directional</i> IE in TS 38.331 [22] | +| 26217 | >>UL UM RLC | ELEMENT | FALSE | | <i>UL-UM-RLC</i> IE in TS 38.331 [22] | +| 26218 | >>DL UM RLC | STRUCTURE | | | <i>DL-UM-RLC</i> IE in TS 38.331 [22] | +| 26219 | >>>Reassembly | ELEMENT | FALSE | <i>t-Reassembly</i> IE in TS 38.331 [22] | | +| 26220 | >UM Uni-directional UL | STRUCTURE | | | <i>um-Uni-Directional-UL</i> IE in TS 38.331 [22] | +| 26221 | >>UL UM RLC | ELEMENT | FALSE | <i>ul-UM-RLC</i> IE in TS 38.331 [22] | | +| 26222 | >UM Uni-directional DL | ELEMENT | FALSE | | <i>um-Uni-Directional-DL</i> IE in TS 38.331 [22] | +| 26223 | >DL UM RLC | STRUCTURE | | | <i>dl-UM-RLC</i> IE in TS 38.331 [22] | +| 26224 | >>Reassembly | ELEMENT | FALSE | <i>t-Reassembly</i> IE in TS 38.331 [22] | | +| 26225 | List of QoS Flows to be setup in DRB | LIST | | | <i>Flow Mapping Information</i> IE in TS 37.483 [21] clause 9.3.1.26 | +| 26226 | >QoS Flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] clause 9.3.1.12 | +| 26227 | >>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] clause 9.3.1.24 | | +| 26228 | >>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 26229 | List of QoS Flows to be modified in DRB | LIST | | | <i>Flow Mapping Information</i> IE in TS 37.483 [21] clause | + +| | | | | | | +|-------|--------------------------------------|-----------|-------|-----------------------------------------------------------------|--------------------------------------------------------------------| +| | | | | | 9.3.1.26 | +| 26230 | >QoS Flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] clause 9.3.1.12 | +| 26231 | >>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] clause 9.3.1.24 | | +| 26232 | >>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 26233 | List of Cell Groups to Add | LIST | | | <i>Cell Group List</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 26234 | >Cell Group Item | STRUCTURE | | | | +| 26255 | >>Cell Group ID | ELEMENT | TRUE | <i>cellGroup</i> IE in TS 38.331 [22] Clause 6 | | +| 26256 | >>Cell Group | STRUCTURE | | 8.1.1.7 | | +| 26235 | List of Cell Groups To Modify/Update | LIST | | | <i>Cell Group List</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 26236 | >Cell Group Item | STRUCTURE | | | | +| 26257 | >>Cell Group ID | ELEMENT | TRUE | <i>cellGroup</i> IE in TS 38.331 [22] Clause 6 | | +| 26258 | >>Cell Group | STRUCTURE | | 8.1.1.7 | | +| 26237 | List of Cell Groups To Delete | LIST | | | <i>Cell Group List</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 26238 | >Cell Group Item | STRUCTURE | | | | +| 26259 | >>Cell Group ID | ELEMENT | TRUE | <i>cellGroup</i> IE in TS 38.331 [22] Clause 6 | | +| 26260 | >>Cell Group | STRUCTURE | | 8.1.1.7 | | +| 26239 | Logical Channel ID | ELEMENT | FALSE | <i>LogicalChannelIdentity</i> IE in TS 38.331 [22] clause 6 | | +| 26240 | Channel Access Priority | ELEMENT | FALSE | <i>channelAccessPriority</i> IE in TS 38.331 [22] | | +| 26241 | L2 State Information | STRUCTURE | | 8.1.1.8 | | +| 26242 | Data Report Usage List | LIST | | | <i>Data Usage Report List</i> IE in TS 37.483 [21] Clause 9.3.1.44 | +| 26243 | >Data Report Usage Item | STRUCTURE | | | <i>Data Report Usage Item</i> IE in TS 37.483 [21] Clause 9.3.1.44 | +| 26244 | >>Start Timestamp | ELEMENT | FALSE | <i>Start timestamp</i> IE in TS 37.483 [21] Clause 9.3.1.44 | | +| 26245 | >>End Timestamp | ELEMENT | FALSE | <i>End timestamp</i> IE in TS 37.483 [21] Clause 9.3.1.44 | | +| 26246 | >>Usage Count DL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21] Clause 9.3.1.44 | | +| 26247 | >>Usage Count UL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21] Clause 9.3.1.44 | | + +### 8.1.2.2.3 Bearer Context Release + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------------|--------------------------|----------|----------------------------------------------------------------------|----------------------------------------------------------------| +| 26301 | DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] clause 9.3.1.16 | | +| 26302 | PDCP DL Count | ELEMENT | FALSE | <i>PDCP DL Count</i> IE in TS 37.483 [21] Clause 9.2.2.11 | | +| 26303 | PDCP UL Count | ELEMENT | FALSE | <i>PDCP UL Count</i> IE in TS 37.483 [21] Clause 9.2.2.11 | | +| 26304 | Release Cause | STRUCTURE | | | <i>Cause</i> IE in TS 37.483 [21] Clause 9.3.1.2 | +| 26305 | >CHOICE Cause Group | STRUCTURE | | | <i>Cause Group</i> IE in TS 37.483 [21] Clause 9.3.1.2 | +| 26306 | >>Radio Network Layer | STRUCTURE | | | <i>Radio Network Layer</i> IE in TS 37.483 [21] Clause 9.3.1.2 | +| 26307 | >>>Radio Network Layer Cause | ELEMENT | FALSE | <i>Radio Network Layer Cause</i> IE in TS 37.483 [21] Clause 9.3.1.2 | | +| 26308 | >>Transport Layer | STRUCTURE | | | <i>Transport Layer</i> IE in TS 37.483 [21] Clause 9.3.1.2 | +| 26309 | >>>Transport Layer Cause | ELEMENT | FALSE | <i>Transport Layer Cause</i> IE in TS 37.483 [21] Clause 9.3.1.2 | | +| 26310 | >>Protocol | STRUCTURE | | | <i>Protocol</i> IE in TS 37.483 [21] Clause 9.3.1.2 | +| 26311 | >>>Protocol Cause | ELEMENT | FALSE | <i>Protocol Cause</i> IE in TS 37.483 [21] Clause 9.3.1.2 | | +| 26312 | >>Miscellaneous | STRUCTURE | | | <i>Misc</i> IE in TS 37.483 [21] Clause 9.3.1.2 | +| 26313 | >>>Miscellaneous Cause | ELEMENT | FALSE | <i>Miscellaneous Cause</i> IE in TS 37.483 [21] Clause 9.3.1.2 | | + +### 8.1.2.3 Mobility Management + +The RAN Parameters for the call process type of “Mobility Management” are defined as follows. + +#### 8.1.2.3.1 Handover Preparation + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------|--------------------------|----------|-------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 27101 | Event AN and inter-RAT B1 mobility thresholds | STRUCTURE | | <i>Connectivity and Mobility Event Thresholds</i> IE in clause 8.1.1.10 | | +| 27102 | List of Serving cells | LIST | | | <i>MeasResultServMOList</i> IE in TS 38.331 [22] | +| 27103 | >Serving Cell Item | STRUCTURE | | | <i>MeasResultServMO</i> IE in TS 38.331 [22] | +| 27104 | >>Serving Cell Index | ELEMENT | TRUE | <i>servCellID</i> IE in TS 38.331 [22] | | +| 27105 | >>CHOICE Serving Cell | STRUCTURE | | | <i>MeasResultServMO</i> IE in TS 38.331 [22] | +| 27106 | >>>NR Cell | STRUCTURE | | 8.1.1.1 | | +| 27107 | >>>E-UTRA Cell | STRUCTURE | | 8.1.1.2 | | +| 27108 | >>CHOICE Best Neighbouring Cell | STRUCTURE | | | <i>measResultBestNeighCell</i> IE in TS 38.331 [22] | +| 27109 | >>>NR Cell | STRUCTURE | | 8.1.1.1 | | +| 27110 | >>>E-UTRA Cell | STRUCTURE | | 8.1.1.2 | | +| 27113 | Primary Cell ID | STRUCTURE | | | This is for the primary serving cell of the UE. The structuring of this parameter is based on <i>Target Cell Global ID</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 27114 | >CHOICE <i>Primary Serving Cell</i> | STRUCTURE | | | The primary cell could either be an NR primary cell or an LTE primary cell. The structuring is based on <i>Target Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 27115 | >>NR SpCell | STRUCTURE | | 8.1.1.1 | <i>NR</i> IE in TS 38.423 [15] clause 9.2.3.25 or <i>SpCellID</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 27116 | >>LTE E-UTRA PCell | STRUCTURE | | 8.1.1.2 | <i>E-UTRA</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 27117 | List of Secondary cells | LIST | | | <i>SCell To Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 27118 | >Secondary Cell Item | STRUCTURE | | | <i>SCell To Be Setup Item IEs</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 27119 | >>Secondary Cell Index | ELEMENT | FALSE | | <i>SCellIndex</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 27120 | >>CHOICE Secondary Cell | STRUCTURE | | | <i>SCell To Be Setup Item IEs</i> IE in TS 38.473 [19] Clause 9.2.2.1 | + +| | | | | | | +|-------|---------------------------------------------------|-----------|-------|--------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 27121 | >>>NR Cell | STRUCTURE | | 8.1.1.1 | | +| 27122 | >>>E-UTRA Cell | STRUCTURE | | 8.1.1.2 | | +| 27123 | List of Neighbour cells | LIST | | | <i>measResultNeigh Cells IE in TS 38.331 [22]</i> | +| 27124 | >Neighbour Cell Item | STRUCTURE | | | <i>measResultNeigh Cells IE in TS 38.331 [22]</i> | +| 27125 | >>CHOICE Neighbour Cell | STRUCTURE | | | <i>measResultNeigh Cells IE in TS 38.331 [22]</i> | +| 27126 | >>>NR Cell | STRUCTURE | | 8.1.1.1 | <i>MeasResultNR IE in TS 38.331 [22]</i> | +| 27127 | >>>E-UTRA Cell | STRUCTURE | | 8.1.1.2 | <i>MeasResultEUTRA IE in TS 38.331 [22]</i> | +| 27128 | Target Primary Cell ID | STRUCTURE | | | <i>Target Cell Global ID IE in TS 38.423 [15] Clause 9.2.3.25</i> | +| 27129 | >CHOICE Target Cell | STRUCTURE | | | <i>Target Cell IE in TS 38.423 [15] Clause 9.2.3.25</i> | +| 27130 | >>NR SpCell | STRUCTURE | | 8.1.1.1 | <i>NR IE in TS 38.423 [15] Clause 9.2.3.25 or SpCell ID IE in TS 38.473 [19] clause 9.2.2.1</i> | +| 27131 | >>LTE E-UTRA PCell | STRUCTURE | | 8.1.1.2 | <i>E-UTRA IE in TS 38.423 [15] Clause 9.2.3.25</i> | +| 27132 | List of Candidate Target cells for conditional HO | LIST | | | <i>Candidate SpCell List IE in TS 38.473 [19] Clause 9.2.2.1</i> | +| 27133 | >Candidate Target cell Item | STRUCTURE | | | <i>Candidate SpCell Item IEs IE in TS 38.473 [19] Clause 9.2.2.1</i> | +| 27134 | >>CHOICE Candidate Target Cell | STRUCTURE | | | <i>Target Cell IE in TS 38.423 [15] Clause 9.2.3.25</i> | +| 27135 | >>>NR SpCell candidate | STRUCTURE | | 8.1.1.1 | <i>NR IE in TS 38.423 [15] clause 9.2.3.25 or SpCell ID IE in TS 38.473 [19] clause 9.2.2.1</i> | +| 27136 | >>>LTE E-UTRA PCell candidate | STRUCTURE | | 8.1.1.2 | <i>E-UTRA IE in TS 38.423 [15] clause 9.2.3.25</i> | +| 27137 | >>Estimated Arrival Probability | ELEMENT | FALSE | <i>Estimated Arrival Probability IE in TS 38.423 [15] Clause 9.1.1.1</i> | | +| 27138 | List of PDU Sessions for Handover | LIST | | | This is the list of PDU sessions of the UE that are subject to handover. The structuring is based on <i>PDU Session Resources To Be Setup List IE in TS 38.423 [15] Clause 9.2.1.1</i> | + +| | | | | | | +|-------|----------------------------------------|-----------|------|-----------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 27139 | >PDU Session Item | STRUCTURE | | | <i>PDU Session Resources To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 27140 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.3.18 | | +| 27141 | >>PDU Session | STRUCTURE | | 8.1.1.16 | | +| 27142 | >>List of QoS flows in the PDU Session | LIST | | | <i>QoS Flows To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 27143 | >>>QoS Flow Item | STRUCTURE | | | <i>QoS Flow To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 27144 | >>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 27145 | >>>>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 27146 | >>List of DRBs for Handover | LIST | | | This is the list of DRBs corresponding to the PDU session to be handed over. The structuring is based on <i>DRB to Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.7 | +| 27147 | >>>DRB Item for Handover | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.7 | +| 27148 | >>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.473 [19] Clause 9.3.1.8 | | +| 27149 | >>>>CHOICE <i>DRB Type</i> | STRUCTURE | | | | +| 27150 | >>>>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 27151 | >>>>>E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 27152 | >>>>List of QoS flows in the DRB | LIST | | | <i>QoS Flows Information To Be Setup</i> IE in TS 37.483 [21] Clause 9.3.3.2 | +| 27153 | >>>>>QoS Flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.25 | +| 27154 | >>>>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] Clause 9.3.1.24 | | +| 27155 | >>>>>>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 27175 | List of DRBs for Handover | LIST | | | <i>DRB to Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 27176 | >DRB Item for Handover | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS | + +| | | | | | | +|-------|-----------------------------------|-----------|------|---------------------------------------------------------------------------|--------------------------------------------------------------------------------------------| +| | | | | | 38.473 [19]<br>Clause 9.2.2.1 | +| 27177 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS<br>38.473 [19]<br>Clause 9.3.1.8 | | +| 27178 | >>CHOICE <i>DRB Type</i> | STRUCTURE | | | | +| 27179 | >>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 27180 | >>>E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 27181 | >>List of QoS flows in the<br>DRB | LIST | | | <i>QoS Flows<br/>Information To Be<br/>Setup</i> IE in TS<br>37.483 [21]<br>Clause 9.3.3.2 | +| 27182 | >>>QoS Flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE<br>in TS 37.483 [21]<br>Clause 9.3.1.25 | +| 27183 | >>>>QoS Flow<br>Identifier | ELEMENT | TRUE | <i>QoS Flow<br/>Identifier</i> IE in TS<br>37.483 [21]<br>Clause 9.3.1.24 | | +| 27184 | >>>>QoS Flow | STRUCTURE | | 8.1.1.6 | | + +#### 8.1.2.3.2 Handover Cancel + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------|--------------------------|----------|-------------------------------------------------------------------------|---------------------------------------------------------------------------------| +| 27201 | Event AN and inter-RAT B1 mobility thresholds | STRUCTURE | | <i>Connectivity and Mobility Event Thresholds IE in clause 8.1.1.10</i> | | +| 27209 | List of candidate cells to be cancelled list | LIST | | | <i>Candidate Cells To Be Cancelled List IE in TS 38.473 [19] Clause 9.2.2.4</i> | +| 27210 | >Candidate cell to be cancelled item | STRUCTURE | | | <i>Candidate Cells To Be Cancelled List IE in TS 38.473 [19] Clause 9.2.2.4</i> | +| 27211 | >>Target cell ID | STRUCTURE | | | <i>Target Cell ID IE in TS 38.473 [19] Clause 9.2.2.4</i> | +| 27212 | >>>CHOICE Target cell ID | STRUCTURE | | | <i>Target Cell ID IE in TS 38.473 [19] Clause 9.2.2.4</i> | +| 27213 | >>>>NR Cell | STRUCTURE | | 8.1.1.1 | | +| 27214 | >>>>LTE E-UTRA Cell | STRUCTURE | | 8.1.1.2 | | +| 27215 | Cause for canceling HO or CHO | STRUCTURE | | | <i>Cause IE in TS 38.423 [15] Clause 9.1.1.6</i> | +| 27216 | >CHOICE Cause Group | STRUCTURE | | | <i>Cause Group IE in TS 38.423 [15] Clause 9.2.3.2</i> | +| 27217 | >>Radio Network Layer | STRUCTURE | | | <i>Radio Network Layer IE in TS 38.423 [15] Clause 9.2.3.2</i> | +| 27218 | >>>Radio Network Layer Cause | ELEMENT | FALSE | <i>Radio Network Layer Cause IE in TS 38.423 [15] Clause 9.2.3.2</i> | | +| 27219 | >>Transport Layer | STRUCTURE | | | <i>Transport Layer IE in TS 38.423 [15] Clause 9.2.3.2</i> | +| 27220 | >>>Transport Layer Cause | ELEMENT | FALSE | <i>Transport Layer Cause IE in TS 38.423 [15] Clause 9.2.3.2</i> | | +| 27221 | >>Protocol | STRUCTURE | | | <i>Protocol IE in TS 38.423 [15] Clause 9.2.3.2</i> | +| 27222 | >>>Protocol Cause | ELEMENT | FALSE | <i>Protocol Cause IE in TS 38.423 [15] Clause 9.2.3.2</i> | | +| 27223 | >>Misc | STRUCTURE | | | <i>Misc IE in TS 38.423 [15] Clause 9.2.3.2</i> | +| 27224 | >>>Miscellaneous Cause | ELEMENT | FALSE | <i>Miscellaneous Cause IE in TS 38.423 [15] Clause 9.2.3.2</i> | | + +### 8.1.2.3.3 Handover Resource Allocation + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------|--------------------------|----------|-------------------------------------------------------------------------|-----------------------------------------------------------------------------------| +| 27301 | Event AN and inter-RAT B1 mobility thresholds | STRUCTURE | | <i>Connectivity and Mobility Event Thresholds</i> IE in clause 8.1.1.10 | | +| 27302 | Handover Type | ELEMENT | FALSE | <i>Handover Type</i> IE in TS 38.413 [11] Clause 9.3.1.22 | | +| 27303 | List of PDU Sessions for Handover | LIST | | | <i>PDU Session Resources To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 27304 | >PDU Session Item | STRUCTURE | | | <i>PDU Session Resources To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 27305 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.3.18 | | +| 27306 | >>PDU Session | STRUCTURE | | 8.1.1.16 | | +| 27307 | >>List of QoS flows in the PDU Session | LIST | | | <i>QoS Flows To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 27308 | >>>QoS Flow Item | LIST | | | <i>QoS Flow To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 27309 | >>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 27310 | >>>>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 27311 | >>List of DRBs for Handover | LIST | | | <i>DRB to Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 27312 | >>>DRB Item for Handover | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 27313 | >>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.473 [19] Clause 9.3.1.8 | | +| 27314 | >>>>CHOICE <i>DRB Type</i> | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 27315 | >>>>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 27316 | >>>>>E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 27317 | >>>>List of QoS flows in the DRB | LIST | | | <i>QoS Flows Information To Be Setup</i> IE in TS 37.483 [21] Clause 9.3.3.2 | +| 27318 | >>>>>QoS Flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.25 | +| 27319 | >>>>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] Clause 9.3.1.24 | | +| 27320 | >>>>>>QoS | STRUCTURE | | 8.1.1.6 | | + +| | | | | | | +|-------|--------------------------------|-----------|-------|-----------------------------------------------------------------|------------------------------------------------------------------------------| +| | Flow | | | | | +| 27321 | List of DRBs for Handover | LIST | | | <i>DRB to Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 27322 | >DRB Item for Handover | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 27323 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.473 [19] Clause 9.3.1.8 | | +| 27324 | >>CHOICE <i>DRB Type</i> | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 27325 | >>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 27326 | >>>E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 27327 | >>List of QoS flows in the DRB | LIST | | | <i>QoS Flows Information To Be Setup</i> IE in TS 37.483 [21] Clause 9.3.3.2 | +| 27328 | >>>QoS Flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.25 | +| 27329 | >>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] Clause 9.3.1.24 | | +| 27330 | >>>>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 27331 | Allowed S-NSSAI | LIST | | | <i>Allowed S-NSSAI</i> IE in TS 38.413 [11] Clause 9.3.1.31 | +| 27332 | >Allowed S-NSSAI Item | STRUCTURE | | | <i>Allowed S-NSSAI Item</i> IE in TS 38.413 [11] Clause 9.3.1.31 | +| 27333 | >>S-NSSAI | STRUCTURE | | | <i>S-NSSAI</i> IE in TS 38.413 [11] Clause 9.3.1.24 | +| 27334 | >>>SST | ELEMENT | TRUE | <i>SST</i> IE in TS 38.413 [11] Clause 9.3.1.24 | | +| 27335 | >>>SD | ELEMENT | FALSE | <i>SD</i> IE in TS 38.413 [11] Clause 9.3.1.24 | | +| 27336 | Mobility Restriction List | STRUCTURE | | | <i>Mobility Restriction List</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27337 | >Serving PLMN | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.413 [11] Clause 9.3.3.5 | | +| 27338 | >List of Equivalent PLMNs | LIST | | | <i>Equivalent PLMNs</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27339 | >>Equivalent PLMN Item | STRUCTURE | | | | +| 27340 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.413 [11] Clause 9.3.3.5 | | +| 27341 | >RAT Restrictions | LIST | | | <i>RAT Restrictions</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27342 | >>RAT Restriction Item | STRUCTURE | | | | +| 27343 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.413 [11] | | + +| | | | | | | +|-------|--------------------------------|-----------|-------|-------------------------------------------------------------------------|------------------------------------------------------------------------| +| | | | | Clause 9.3.3.5 | | +| 27344 | >>>RAT Restriction Information | ELEMENT | FALSE | <i>RAT Restriction Information</i> IE in TS 38.413 [11] Clause 9.3.1.85 | | +| 27345 | >Forbidden Area Information | LIST | | | <i>Forbidden Area Information</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27346 | >>Forbidden Area | STRUCTURE | | | <i>Forbidden Area Information</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27347 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.413 [11] Clause 9.3.3.5 | | +| 27348 | >>>List of Forbidden TACs | LIST | | | <i>Forbidden TACs</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27349 | >>>>Forbidden TAC Item | STRUCTURE | | | <i>Forbidden TACs</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27350 | >>>>>TAC | ELEMENT | FALSE | <i>TAC</i> IE in TS 38.413 [11] Clause 9.3.3.10 | | +| 27351 | >Service Area Information | LIST | | | <i>Service Area Information</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27352 | >>Service Area | STRUCTURE | | | <i>Service Area Information</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27353 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.413 [11] Clause 9.3.3.5 | | +| 27364 | >>>List of allowed TACs | LIST | | | <i>Allowed TACs</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27365 | >>>>Allowed TAC Item | STRUCTURE | | | <i>Allowed TACs</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27366 | >>>>>TAC | ELEMENT | FALSE | <i>TAC</i> IE in TS 38.413 [11] Clause 9.3.3.10 | | +| 27367 | >>>List of Not allowed TACs | LIST | | | <i>Not Allowed TACs</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27368 | >>>>Not Allowed TAC Item | STRUCTURE | | | <i>Not Allowed TACs</i> IE in TS 38.413 [11] Clause 9.3.1.85 | +| 27369 | >>>>>TAC | ELEMENT | FALSE | <i>TAC</i> IE in TS 38.413 [11] Clause 9.3.3.10 | | + +## 8.1.2.4 Multi-RAT Dual Connectivity Management + +The RAN Parameters for the call process type of “Multi-RAT Dual Connectivity Management” are defined as follows. + +### 8.1.2.4.1 SN Addition + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------------------------|--------------------------|----------|--------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------| +| 28101 | Event AN and inter-RAT B1 mobility thresholds | STRUCTURE | | <i>Connectivity and Mobility Event Thresholds</i> IE in clause 8.1.1.10 | | +| 28102 | Secondary Node | STRUCTURE | | 8.1.1.11 | | +| 28103 | CHOICE <i>PDCP Change Indication</i> | STRUCTURE | | | <i>PDCP Change Indication</i> IE in TS 38.423 [15] Clause 9.2.3.74 | +| 28104 | >From S-NG-RAN Node | STRUCTURE | | | <i>From S-NG-RAN Node</i> IE in TS 38.423 [15] Clause 9.2.3.74 | +| 28105 | >>Indication from S-NG-RAN node to M-NG-RAN node | ELEMENT | FALSE | <i>Indication from S-NG-RAN node to M-NG-RAN node</i> IE in TS 38.423 [15] Clause 9.2.3.74 | | +| 28106 | >From M-NG-RAN Node | STRUCTURE | | | <i>From M-NG-RAN Node</i> IE in TS 38.423 [15] Clause 9.2.3.74 | +| 28107 | >>Indication from M-NG-RAN node to S-NG-RAN node | ELEMENT | FALSE | <i>Indication from M-NG-RAN node to S-NG-RAN node</i> IE in TS 38.423 [15] Clause 9.2.3.74 | | +| 28108 | Secondary Node UE Aggregate Maximum Bit Rate | STRUCTURE | | | <i>UE Aggregate Maximum Bit Rate</i> IE in TS 36.423 [17] Clause 9.2.12 | +| 28109 | >UE Aggregate Maximum Bit Rate Downlink | ELEMENT | FALSE | <i>UE Aggregate Maximum Bit Rate Downlink</i> IE in TS 36.423 [17] clause 9.2.12 | | +| 28110 | >UE Aggregate Maximum Bit Rate Uplink | ELEMENT | FALSE | <i>UE Aggregate Maximum Bit Rate Uplink</i> IE in TS 36.423 [17] clause 9.2.12 | | +| 28111 | List of PDU sessions to be added | LIST | | | <i>PDU Session Resources To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 28112 | >PDU Session Item | STRUCTURE | | | <i>PDU Session Resources To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 28113 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.3.18 | | +| 28114 | >>PDU Session | STRUCTURE | | 8.1.1.16 | | + +| | | | | | | +|-------|----------------------------------------|-----------|-------|-----------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------| +| 28115 | >>CHOICE <i>PDU Session Setup Info</i> | STRUCTURE | | | <i>PDU Session Resource Setup Info – SN terminated</i><br>IE in TS<br>38.423 [15]<br>Clause 9.1.2.5 | +| 28116 | >>>SN terminated PDU session | STRUCTURE | | | <i>PDU Session Resource Setup Info – SN terminated</i><br>IE in TS<br>38.423 [15]<br>Clause 9.1.2.5 | +| 28118 | >>>>List of QoS flows to be setup | LIST | | | <i>QoS Flows To Be Setup List</i><br>IE in TS<br>38.423 [15]<br>Clause 9.2.1.1 | +| 28119 | >>>>>QoS flow Item to be setup | STRUCTURE | | | <i>QoS Flow To Be Setup Item</i><br>IE in TS<br>38.423 [15]<br>Clause 9.2.1.1 | +| 28120 | >>>>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS<br>38.423 [15]<br>Clause 9.2.3.10 | | +| 28121 | >>>>>>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 28122 | >>>>Count of QoS flows to be setup | ELEMENT | FALSE | INTEGER (0..64) | | +| 28123 | >>>MN terminated PDU session | STRUCTURE | | | <i>PDU Session Resource Setup Info – MN terminated</i><br>IE in TS<br>38.423 [15]<br>Clause 9.1.2.5 | +| 28125 | >>>>List of DRBs to be setup | LIST | | | <i>DRB to QoS Flow Mapping List</i> IE in TS<br>38.423 [15]<br>Clause 9.2.1.15 | +| 28126 | >>>>>DRB Item to be setup | STRUCTURE | | | <i>DRB to QoS Flow Mapping Item</i> IE in TS<br>38.423 [15]<br>Clause 9.2.1.15 | +| 28127 | >>>>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS<br>38.423 [15]<br>Clause 9.2.3.33 | | +| 28128 | >>>>>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 28129 | >>>>>>List of QoS flows to be setup | LIST | | | <i>QoS Flows List</i><br>IE in TS<br>38.423 [15]<br>Clause 9.2.1.15 | +| 28130 | >>>>>>>QoS flow Item to be setup | STRUCTURE | | | <i>QoS Flow Item</i><br>IE in TS<br>38.423 [15]<br>Clause 9.2.1.15 | +| 28131 | >>>>>>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS<br>38.423 [15] | | + +| | | | | | | +|-------|-------------------------------------------------------|-----------|-------|-------------------------------------------------------------|-------------------------------------------------------------------------| +| | | | | Clause 9.2.3.10 | | +| 28132 | >>>>>>>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 28133 | >>>>>Count of list of QoS flows to be setup | ELEMENT | FALSE | INTEGER (0..64) | | +| 28134 | >>>>Count of list of DRBs to be setup | ELEMENT | FALSE | INTEGER (0..64) | | +| 28135 | Count of list of PDU sessions to be added | ELEMENT | FALSE | INTEGER (0..256) | | +| 28136 | List of E-RABs to be added | LIST | | | <i>E-RABs To Be Added List IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28137 | >E-RAB Item | STRUCTURE | | | <i>E-RABs To Be Added Item IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28138 | >>E-RAB ID | ELEMENT | TRUE | <i>E-RAB ID IE in TS 36.423 [17] Clause 9.2.23</i> | | +| 28139 | >>E-RAB | STRUCTURE | | 8.1.1.9 | | +| 28140 | >>EN-DC Resource Configuration | STRUCTURE | | | <i>EN-DC Resource Configuration IE in TS 36.423 [17] Clause 9.2.108</i> | +| 28141 | >>>PDCP at SgNB | ELEMENT | FALSE | <i>PDCP at SgNB IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28142 | >>>MCG resources | ELEMENT | FALSE | <i>MCG resources IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28143 | >>>SCG resources | ELEMENT | FALSE | <i>SCG resources IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28144 | >>CHOICE Resource Configuration | STRUCTURE | | | <i>Resource Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28145 | >>>PDCP present in SN | STRUCTURE | | | <i>PDCP Present in SN IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28146 | >>>>Maximum MCG admissible E-RAB Level QoS parameters | STRUCTURE | | 8.1.1.9 | | +| 28147 | >>>>RLC Mode | ELEMENT | FALSE | <i>RLC Mode IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28148 | >>>>UL Configuration | ELEMENT | FALSE | <i>UL Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28149 | >>>PDCP not present in SN | STRUCTURE | | | <i>PDCP Not Present in SN IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28150 | >>>>Requested SCG E-RAB Level QoS Parameters | STRUCTURE | | 8.1.1.9 | | + +| | | | | | | +|-------|-------------------------------------|-----------|-------|-------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 28151 | >>>>RLC Mode | ELEMENT | FALSE | <i>RLC Mode</i> IE in TS 36.423 [17] Clause 9.1.4.1 | | +| 28152 | >>>>UL Configuration | ELEMENT | FALSE | <i>UL Configuration</i> IE in TS 36.423 [17] Clause 9.1.4.1 | | +| 28153 | Count of list of E-RABs to be added | ELEMENT | FALSE | INTEGER (0..256) | | +| 28154 | List of SN-terminated DRBs | LIST | | | <i>Available DRB IDs</i> IE in TS 38.423 [15] Clause 9.1.2.1 | +| 28155 | >SN-terminated DRB item | STRUCTURE | | | | +| 28156 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.423 [15] Clause 9.2.3.33 | | +| 28157 | >>CHOICE <i>DRB Type</i> | STRUCTURE | | | | +| 28158 | >>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 28159 | >>>E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 28160 | Count of list of SN-terminated DRBs | ELEMENT | FALSE | INTEGER (0..64) | | +| 28161 | Primary Cell ID | STRUCTURE | | | This is for the primary serving cell of the UE. The structuring of this parameter is based on <i>Target Cell Global ID</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 28162 | >CHOICE Primary Cell | STRUCTURE | | | The primary cell could either be an NR primary cell or an LTE primary cell. The structuring is based on <i>Target Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 28163 | >>NR SpCell | STRUCTURE | | 8.1.1.1 | <i>NR Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 or <i>SpCell ID</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 28164 | >>LTE PCell | STRUCTURE | | 8.1.1.2 | <i>E-UTRA Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | + +#### 8.1.2.4.2 SN Modification and deletion + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------------------------|--------------------------|----------|--------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------| +| 28201 | Event AN and inter-RAT B1 mobility thresholds | STRUCTURE | | <i>Connectivity and Mobility Event Thresholds</i> IE in clause 8.1.1.10 | Event AN and inter-RAT B1 mobility thresholds | +| 28202 | Secondary Node | STRUCTURE | | 8.1.1.11 | | +| 28205 | CHOICE <i>PDCP Change Indication</i> | STRUCTURE | | | <i>PDCP Change Indication</i> IE in TS 38.423 [15] Clause 9.2.3.74 | +| 28206 | >From S-NG-RAN Node | STRUCTURE | | | <i>From S-NG-RAN Node</i> IE in TS 38.423 [15] Clause 9.2.3.74 | +| 28207 | >>Indication from S-NG-RAN node to M-NG-RAN node | ELEMENT | | <i>Indication from S-NG-RAN node to M-NG-RAN node</i> IE in TS 38.423 [15] Clause 9.2.3.74 | | +| 28208 | >From M-NG-RAN Node | STRUCTURE | | | <i>From M-NG-RAN Node</i> IE in TS 38.423 [15] Clause 9.2.3.74 | +| 28209 | >>Indication from M-NG-RAN node to S-NG-RAN node | ELEMENT | | <i>Indication from M-NG-RAN node to S-NG-RAN node</i> IE in TS 38.423 [15] Clause 9.2.3.74 | | +| 28210 | Secondary Node UE Aggregate Maximum Bit Rate | STRUCTURE | | | <i>UE Aggregate Maximum Bit Rate</i> IE in TS 36.423 [17] Clause 9.2.12 | +| 28211 | >UE Aggregate Maximum Bit Rate Downlink | ELEMENT | FALSE | <i>UE Aggregate Maximum Bit Rate Downlink</i> IE in TS 36.423 [17] clause 9.2.12 | | +| 28212 | >UE Aggregate Maximum Bit Rate Uplink | ELEMENT | FALSE | <i>UE Aggregate Maximum Bit Rate Uplink</i> IE in TS 36.423 [17] clause 9.2.12 | | +| 28213 | List of PDU sessions to be added | LIST | | | <i>PDU Session Resources To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 28214 | >PDU Session Item | STRUCTURE | | | <i>PDU Session Resources To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 28215 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.3.18 | | +| 28216 | >>PDU Session | STRUCTURE | | 8.1.1.16 | | + +| | | | | | | +|-------|----------------------------------------|-----------|-------|-----------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------| +| 28217 | >>CHOICE <i>PDU Session Setup Info</i> | STRUCTURE | | | <i>PDU Session Resource Setup Info – SN terminated</i><br>IE in TS<br>38.423 [15]<br>Clause 9.1.2.5 | +| 28218 | >>>SN terminated PDU session | STRUCTURE | | | <i>PDU Session Resource Setup Info – SN terminated</i><br>IE in TS<br>38.423 [15]<br>Clause 9.1.2.5 | +| 28219 | >>>>List of QoS flows to be setup | LIST | | | <i>QoS Flows To Be Setup List</i><br>IE in TS<br>38.423 [15]<br>Clause 9.2.1.1 | +| 28220 | >>>>>QoS flow Item to be setup | STRUCTURE | | | <i>QoS Flow To Be Setup Item</i><br>IE in TS<br>38.423 [15]<br>Clause 9.2.1.1 | +| 28221 | >>>>>>QoS Flow Indicator | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS<br>38.423 [15]<br>Clause 9.2.3.10 | | +| 28222 | >>>>>>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 28223 | >>>>Count of QoS flows to be setup | ELEMENT | FALSE | INTEGER (0..64) | | +| 28224 | >>>MN terminated PDU session | STRUCTURE | | | <i>PDU Session Resource Setup Info – MN terminated</i><br>IE in TS<br>38.423 [15]<br>Clause 9.1.2.5 | +| 28225 | >>>>List of DRBs to be setup | LIST | | | <i>DRB to QoS Flow Mapping List</i> IE in TS<br>38.423 [15]<br>Clause 9.2.1.15 | +| 28226 | >>>>>>DRB Item to be setup | STRUCTURE | | | <i>DRB to QoS Flow Mapping Item</i> IE in TS<br>38.423 [15]<br>Clause 9.2.1.15 | +| 28227 | >>>>>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS<br>38.423 [15]<br>Clause 9.2.3.33 | | +| 28228 | >>>>>>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 28229 | >>>>>>>List of QoS flows to be setup | LIST | | | <i>QoS Flows List</i><br>IE in TS<br>38.423 [15]<br>Clause 9.2.1.15 | +| 28230 | >>>>>>>>QoS flow Item to be setup | STRUCTURE | | | <i>QoS Flow Item</i><br>IE in TS<br>38.423 [15]<br>Clause 9.2.1.15 | +| 28231 | >>>>>>>>>QoS Flow Indicator | ELEMENT | TRUE | <i>QoS Flow Indicator</i> IE in TS<br>38.423 [15] | | + +| | | | | | | +|-------|-----------------------------------------------|-----------|-------|-----------------------------------------------------------------|--------------------------------------------------------------------------------------------| +| | | | | Clause 9.2.3.10 | | +| 28232 | >>>>>>>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 28233 | >>>>>>Count of list of QoS flows to be setup | ELEMENT | FALSE | INTEGER (0..64) | | +| 28234 | >>>>Count of list of DRBs to be setup | ELEMENT | FALSE | INTEGER (0..64) | | +| 28235 | Count of list of PDU sessions to be added | ELEMENT | FALSE | INTEGER (0..256) | | +| 28236 | List of PDU sessions to be modified | LIST | | | <i>PDU Session Resources To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 28237 | >PDU Session Item | STRUCTURE | | | <i>PDU Session Resources To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 28238 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.3.18 | | +| 28239 | >>PDU Session | STRUCTURE | | 8.1.1.16 | | +| 28240 | >>CHOICE <i>PDU Session Modification Info</i> | STRUCTURE | | | | +| 28241 | >>>SN terminated PDU session | STRUCTURE | | | <i>PDU Session Resource Setup Info – SN terminated</i> IE in TS 38.423 [15] Clause 9.1.2.5 | +| 28242 | >>>>List of QoS flows to be modified | LIST | | | <i>QoS Flows To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 28243 | >>>>>QoS flow Item to be modified | STRUCTURE | | | <i>QoS Flow To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 28244 | >>>>>QoS Flow Indicator | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 28245 | >>>>>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 28246 | >>>>Count of QoS flows to be modified | ELEMENT | FALSE | INTEGER (0..64) | | +| 28247 | >>>MN terminated PDU session | STRUCTURE | | | <i>PDU Session Resource Setup Info – MN terminated</i> IE in TS 38.423 [15] Clause 9.1.2.5 | +| 28248 | >>>>List of DRBs to be modified | LIST | | | <i>DRB to QoS Flow Mapping List</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 28249 | >>>>>DRB Item to be modified | STRUCTURE | | | <i>DRB to QoS Flow Mapping</i> | + +| | | | | | | +|-------|-----------------------------------------------|-----------|-------|-------------------------------------------------------------------|------------------------------------------------------------------------| +| | | | | | <i>Item</i> IE in TS 38.423 [15]<br>Clause 9.2.1.15 | +| 28250 | >>>>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.423 [15]<br>Clause 9.2.3.33 | | +| 28251 | >>>>>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 28252 | >>>>>>List of QoS flows to be modified | LIST | | | <i>QoS Flows List</i> IE in TS 38.423 [15]<br>Clause 9.2.1.15 | +| 28253 | >>>>>>QoS flow Item to be setup | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 38.423 [15]<br>Clause 9.2.1.15 | +| 28254 | >>>>>>>QoS Flow Indicator | ELEMENT | TRUE | <i>QoS Flow Indicator</i> IE in TS 38.423 [15]<br>Clause 9.2.3.10 | | +| 28255 | >>>>>>>QoS Flow | STRUCTURE | | 8.1.1.6 | | +| 28256 | >>>>>>>Count of list of QoS flows to be setup | ELEMENT | FALSE | INTEGER (0..64) | | +| 28257 | >>>>Count of list of DRBs to be modified | ELEMENT | FALSE | INTEGER (0..64) | | +| 28258 | >>MR-DC Usage Information | STRUCTURE | | | <i>MR-DC Usage Information</i> IE in TS 37.483 [21]<br>Clause 9.3.1.63 | +| 28259 | >>>Secondary RAT Type | ELEMENT | FALSE | <i>Secondary RAT Type</i> IE in TS 37.483 [21]<br>Clause 9.3.1.63 | | +| 28260 | >>>PDU Session Timed Report List | LIST | | | <i>Data Usage Report List</i> IE in TS 37.483 [21]<br>Clause 9.3.1.64 | +| 28261 | >>>>MR-DC Data Usage Report Item | STRUCTURE | | | <i>Data Report Usage Item</i> IE in TS 37.483 [21]<br>Clause 9.3.1.64 | +| 28262 | >>>>>Start Timestamp | ELEMENT | FALSE | <i>Start timestamp</i> IE in TS 37.483 [21]<br>Clause 9.3.1.64 | | +| 28263 | >>>>>End Timestamp | ELEMENT | FALSE | <i>End timestamp</i> IE in TS 37.483 [21]<br>Clause 9.3.1.64 | | +| 28264 | >>>>>Usage Count UL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21]<br>Clause 9.3.1.64 | | +| 28265 | >>>>>Usage Count DL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21]<br>Clause 9.3.1.64 | | +| 28266 | >>MR-DC Usage for QoS flows | LIST | | | <i>Data Usage Per QoS Flow List</i> IE in TS 37.483 [21] | + +| | | | | | | +|-------|----------------------------------------------|-----------|-------|----------------------------------------------------------------|---------------------------------------------------------------------------------------| +| | | | | | Clause 9.3.1.63 | +| 28267 | >>>QoS Flow Item | STRUCTURE | | | <i>Data Usage Per QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.63 | +| 28268 | >>>>QoS flow Indicator | ELEMENT | TRUE | <i>QoS Flow Indicator</i> IE in TS 37.483 [21] Clause 9.3.1.24 | | +| 28269 | >>>>Secondary RAT Type | ELEMENT | FALSE | <i>Secondary RAT Type</i> IE in TS 37.483 [21] Clause 9.3.1.63 | | +| 28270 | >>>>QoS Flow Timed Report List | LIST | | | <i>Data Usage Report List</i> IE in TS 37.483 [21] Clause 9.3.1.64 | +| 28271 | >>>>>MR-DC Data Usage Report Item | STRUCTURE | | | <i>Data Report Usage Item</i> IE in TS 37.483 [21] Clause 9.3.1.64 | +| 28272 | >>>>>>Start Timestamp | ELEMENT | FALSE | <i>Start timestamp</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 28273 | >>>>>>End timestamp | ELEMENT | FALSE | <i>End timestamp</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 28274 | >>>>>>Usage Count UL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 28275 | >>>>>>Usage Count DL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 28276 | Count of list of PDU sessions to be modified | ELEMENT | FALSE | INTEGER (0..256) | | +| 28277 | List of PDU sessions to be released | LIST | | | <i>PDU Session Resources To Be Released List</i> IE in TS 38.423 [15] Clause 9.1.2.14 | +| 28278 | >PDU Session Item | STRUCTURE | | | <i>PDU Session List With Cause</i> IE in TS 38.423 [15] Clause 9.2.1.26 | +| 28279 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.3.18 | | +| 28280 | >>PDU Session | STRUCTURE | | 8.1.1.16 | | +| 26281 | >>Release Cause | STRUCTURE | | | <i>Cause</i> IE in TS 37.483 [21] Clause 9.3.1.2 | +| 26282 | >>>CHOICE Cause Group | STRUCTURE | | | <i>Cause Group</i> IE in TS | + +| | | | | | | +|-------|----------------------------------------------|-----------|-------|----------------------------------------------------------------------|-------------------------------------------------------------------------| +| | | | | | 37.483 [21]<br>Clause 9.3.1.2 | +| 26283 | >>>>Radio Network Layer | STRUCTURE | | | <i>Radio Network Layer IE in TS 37.483 [21] Clause 9.3.1.2</i> | +| 26284 | >>>>>Radio Network Layer Cause | ELEMENT | FALSE | <i>Radio Network Layer Cause IE in TS 37.483 [21] Clause 9.3.1.2</i> | | +| 26285 | >>>>Transport Layer | STRUCTURE | | | <i>Transport Layer IE in TS 37.483 [21] Clause 9.3.1.2</i> | +| 26286 | >>>>>Transport Layer Cause | ELEMENT | FALSE | <i>Transport Layer Cause IE in TS 37.483 [21] Clause 9.3.1.2</i> | | +| 26287 | >>>>Protocol | STRUCTURE | | | <i>Protocol IE in TS 37.483 [21] Clause 9.3.1.2</i> | +| 26288 | >>>>>Protocol Cause | ELEMENT | FALSE | <i>Protocol Cause IE in TS 37.483 [21] Clause 9.3.1.2</i> | | +| 26289 | >>>>Miscellaneous | STRUCTURE | | | <i>Misc IE in TS 37.483 [21] Clause 9.3.1.2</i> | +| 26290 | >>>>>Miscellaneous Cause | ELEMENT | FALSE | <i>Miscellaneous Cause IE in TS 37.483 [21] Clause 9.3.1.2</i> | | +| 28291 | Count of list of PDU sessions to be released | ELEMENT | FALSE | INTEGER (0..256) | | +| 28292 | List of E-RABs to be added | LIST | | | <i>E-RABs To Be Added List IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28293 | >E-RAB Item | STRUCTURE | | | <i>E-RABs To Be Added Item IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28294 | >>E-RAB ID | ELEMENT | TRUE | <i>E-RAB ID IE in TS 36.423 [17] Clause 9.2.23</i> | | +| 28295 | >>E-RAB | STRUCTURE | | 8.1.1.9 | | +| 28296 | >>EN-DC Resource Configuration | STRUCTURE | | | <i>EN-DC Resource Configuration IE in TS 36.423 [17] Clause 9.2.108</i> | +| 28297 | >>>PDCP at SgNB | ELEMENT | | <i>PDCP at SgNB IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28298 | >>>MCG resources | ELEMENT | | <i>MCG resources IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28299 | >>>SCG resources | ELEMENT | | <i>SCG resources IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28300 | >>CHOICE Resource Configuration | STRUCTURE | | | <i>Resource</i> | + +| | | | | | | +|-------|-------------------------------------------------------|-----------|-------|-------------------------------------------------------------|-------------------------------------------------------------------------| +| | | | | | <i>Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28301 | >>>PDCP present in SN | STRUCTURE | | | <i>PDCP Present in SN IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28302 | >>>>Maximum MCG admissible E-RAB Level QoS parameters | STRUCTURE | | 8.1.1.9 | | +| 28303 | >>>>RLC Mode | ELEMENT | FALSE | <i>RLC Mode IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28304 | >>>>UL Configuration | ELEMENT | FALSE | <i>UL Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28305 | >>>PDCP not present in SN | STRUCTURE | | | <i>PDCP Not Present in SN IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28306 | >>>>Requested SCG E-RAB Level QoS Parameters | STRUCTURE | | 8.1.1.9 | | +| 28307 | >>>>RLC Mode | ELEMENT | FALSE | <i>RLC Mode IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28308 | >>>>UL Configuration | ELEMENT | FALSE | <i>UL Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28309 | Count of list of E-RABs to be added | ELEMENT | FALSE | INTEGER (0..256) | | +| 28310 | List of E-RABs to be modified | LIST | | | <i>E-RABs To Be Modified List IE in TS 36.423 [17] Clause 9.1.4.5</i> | +| 28311 | >E-RAB Item | STRUCTURE | | | <i>E-RABs To Be Modified Item IE in TS 36.423 [17] Clause 9.1.4.5</i> | +| 28312 | >>E-RAB ID | ELEMENT | TRUE | <i>E-RAB ID IE in TS 36.423 [17] Clause 9.2.23</i> | | +| 28313 | >>E-RAB | STRUCTURE | | 8.1.1.9 | | +| 28314 | >>EN-DC Resource Configuration | STRUCTURE | | | <i>EN-DC Resource Configuration IE in TS 36.423 [17] Clause 9.2.108</i> | +| 28315 | >>>PDCP at SgNB | ELEMENT | | <i>PDCP at SgNB IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28316 | >>>MCG resources | ELEMENT | | <i>MCG resources IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28317 | >>>SCG resources | ELEMENT | | <i>SCG resources IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28318 | >>CHOICE Resource Configuration | STRUCTURE | | | <i>Resource</i> | + +| | | | | | | +|-------|-------------------------------------------------------|-----------|-------|-------------------------------------------------------------|-------------------------------------------------------------------------| +| | | | | | <i>Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28319 | >>>PDCP present in SN | STRUCTURE | | | <i>PDCP Present in SN IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28320 | >>>>Maximum MCG admissible E-RAB Level QoS parameters | STRUCTURE | | 8.1.1.9 | | +| 28321 | >>>>RLC Mode | ELEMENT | FALSE | <i>RLC Mode IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28322 | >>>>UL Configuration | ELEMENT | FALSE | <i>UL Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28323 | >>>PDCP not present in SN | STRUCTURE | | | <i>PDCP Not Present in SN IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28324 | >>>>Requested SCG E-RAB Level QoS Parameters | STRUCTURE | | 8.1.1.9 | | +| 28325 | >>>>RLC Mode | ELEMENT | FALSE | <i>RLC Mode IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28326 | >>>>UL Configuration | ELEMENT | FALSE | <i>UL Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28327 | Count of list of E-RABs to be modified | ELEMENT | FALSE | INTEGER (0..256) | | +| 28328 | List of E-RABs to be released | LIST | | | <i>E-RABs To Be Released List IE in TS 36.423 [17] Clause 9.1.4.5</i> | +| 28329 | >E-RAB Item | STRUCTURE | | | <i>E-RABs To Be Released Item IE in TS 36.423 [17] Clause 9.1.4.5</i> | +| 28330 | >>E-RAB ID | ELEMENT | TRUE | <i>E-RAB ID IE in TS 36.423 [17] Clause 9.2.23</i> | | +| 28331 | >>E-RAB | STRUCTURE | | 8.1.1.9 | | +| 28332 | >>EN-DC Resource Configuration | STRUCTURE | | | <i>EN-DC Resource Configuration IE in TS 36.423 [17] Clause 9.2.108</i> | +| 28333 | >>>PDCP at SgNB | ELEMENT | FALSE | <i>PDCP at SgNB IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28334 | >>>MCG resources | ELEMENT | FALSE | <i>MCG resources IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28335 | >>>SCG resources | ELEMENT | FALSE | <i>SCG resources IE in TS 36.423 [17] Clause 9.2.108</i> | | +| 28336 | >>CHOICE Resource Configuration | STRUCTURE | | | <i>Resource</i> | + +| | | | | | | +|-------|-------------------------------------------------------|-----------|-------|-------------------------------------------------------------|-------------------------------------------------------------------| +| | | | | | <i>Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28337 | >>>PDCP present in SN | STRUCTURE | | | <i>PDCP Present in SN IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28338 | >>>>Maximum MCG admissible E-RAB Level QoS parameters | STRUCTURE | | 8.1.1.9 | | +| 28339 | >>>>RLC Mode | ELEMENT | FALSE | <i>RLC Mode IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28340 | >>>>UL Configuration | ELEMENT | FALSE | <i>UL Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28341 | >>>PDCP not present in SN | STRUCTURE | | | <i>PDCP Not Present in SN IE in TS 36.423 [17] Clause 9.1.4.1</i> | +| 28342 | >>>>Requested SCG E-RAB Level QoS Parameters | STRUCTURE | | 8.1.1.9 | | +| 28343 | >>>>RLC Mode | ELEMENT | FALSE | <i>RLC Mode IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28344 | >>>>UL Configuration | ELEMENT | FALSE | <i>UL Configuration IE in TS 36.423 [17] Clause 9.1.4.1</i> | | +| 28345 | Count of list of E-RABs to be released | ELEMENT | FALSE | INTEGER (0..256) | | +| 28346 | List of SN-terminated DRBs to be modified or released | LIST | | | <i>Additional DRB IDs IE in TS 38.423 [15] Clause 9.1.2.5</i> | +| 28347 | >SN-terminated DRB item | STRUCTURE | | | <i>Additional DRB IDs IE in TS 38.423 [15] Clause 9.1.2.5</i> | +| 28358 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID IE in TS 38.423 [15] Clause 9.2.3.33</i> | | +| 28348 | >>CHOICE <i>DRB Type</i> | STRUCTURE | | | <i>Additional DRB IDs IE in TS 38.423 [15] Clause 9.1.2.5</i> | +| 28349 | >>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 28350 | >>>E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 28351 | Count of list of SN-terminated DRBs | ELEMENT | FALSE | INTEGER (0..64) | | +| 28352 | Primary Cell ID | STRUCTURE | | | <i>SpCell ID IE in TS 38.473 [19] clause 9.2.2.1</i> | +| 28353 | >CHOICE Primary Cell | STRUCTURE | | | <i>SpCell ID IE in TS 38.473 [19] clause 9.2.2.1</i> | +| 28354 | >>NR SpCell | STRUCTURE | | 8.1.1.1 | | +| 28355 | >>LTE PCell | STRUCTURE | | 8.1.1.2 | | + +## 8.1.2.5 Radio Resource Control Management + +The RAN Parameters for the call process type of “Radio Resource Control Management” are defined as follows. + +### 8.1.2.5.1 RRC CG-Config Information Transfer + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------|--------------------------|----------|-------------------------------------------|-----------------------------------------------------------| +| 29001 | CG-ConfigInfo | STRUCTURE | | | TS 38.473 [19] clause 9.3.1.25 | +| 29011 | >MN Candidate Cell List Info | STRUCTURE | | | <i>candidateCellInfoListMN</i> IE in TS 38.331 [22] | +| 29012 | >>List of NR Cell Measurements | LIST | | | <i>MeasResultList2NR</i> IE in TS 38.331 [22] | +| 29013 | >>>NR Cell Measurement Item | STRUCTURE | | | <i>MeasResult2NRItem</i> IE in TS 38.331 [22] | +| 29014 | >>>>SSB Frequency | ELEMENT | FALSE | <i>ssbFrequency</i> IE in TS 38.331 [22] | | +| 29015 | >>>>CSI-RS Reference Frequency | ELEMENT | FALSE | <i>refFreqCSI-RS</i> IE in TS 38.331 [22] | | +| 29016 | >>>>NR Serving Cell | STRUCTURE | | | <i>measResultServingCell</i> IE in TS 38.331 [22] | +| 29017 | >>>>NR Neighbour Cell Measurement List | LIST | | | <i>measResultNeighbourCellListNR</i> IE in TS 38.331 [22] | +| 29018 | >>>>>NR Neighbour Cell Measurement Item | STRUCTURE | | | <i>measResultNRItem</i> IE in TS 38.331 [22] | +| 29019 | >>>>>>NR Neighbour Cell | STRUCTURE | | <i>NR Cell</i> in 8.1.1.1 | | +| 29021 | >SN Candidate Cell List Info | STRUCTURE | | | <i>candidateCellInfoListMN</i> IE in TS 38.331 [22] | +| 29022 | >>List of NR Cell Measurements | LIST | | | <i>MeasResultList2NR</i> IE in TS 38.331 [22] | +| 29023 | >>>NR Cell Measurement Item | STRUCTURE | | | <i>MeasResult2NRItem</i> IE in TS 38.331 [22] | +| 29024 | >>>>SSB Frequency | ELEMENT | FALSE | <i>ssbFrequency</i> IE in TS 38.331 [22] | | +| 29025 | >>>>CSI-RS Reference Frequency | ELEMENT | FALSE | <i>refFreqCSI-RS</i> IE in TS 38.331 [22] | | +| 29026 | >>>>NR Serving Cell | STRUCTURE | | | <i>measResultServingCell</i> IE in TS 38.331 [22] | +| 29027 | >>>>NR Neighbour Cell Measurement List | LIST | | | <i>measResultNeighbourCellListNR</i> IE in TS 38.331 [22] | +| 29028 | >>>>>NR Neighbour Cell Measurement Item | STRUCTURE | | | <i>measResultNRItem</i> IE in TS 38.331 [22] | +| 29029 | >>>>>>NR Neighbour Cell | STRUCTURE | | <i>NR Cell</i> in 8.1.1.1 | | +| 29031 | >SCG Failure Info | STRUCTURE | | | <i>FailureReportSCG</i> IE in TS 38.331 [22] | +| 29032 | >>Failure Type | ELEMENT | FALSE | <i>failureType</i> IE in TS 38.331 [22] | | +| 29033 | >>Meas Result SCG Failure | STRUCTURE | | | <i>measResultSCG-Failure</i> IE in TS | + +| | | | | | | +|-------|---------------------------------------------------|-----------|-------|------------------------------------------------------|-----------------------------------------------------------| +| | | | | | 38.331 [22] | +| 29034 | >>>Measurement Result List Per Measurement Object | STRUCTURE | | | <i>measResultPerMOList</i> IE in TS 38.331 [22] | +| 29035 | >>>>List of NR Cell Measurements | LIST | | | <i>MeasResultList2NR</i> IE in TS 38.331 [22] | +| 29036 | >>>>>NR Cell Measurement Item | STRUCTURE | | | <i>MeasResult2NRItem</i> IE in TS 38.331 [22] | +| 29037 | >>>>>>SSB Frequency | ELEMENT | FALSE | <i>ssbFrequency</i> IE in TS 38.331 [22] | | +| 29038 | >>>>>>CSI-RS Reference Frequency | ELEMENT | FALSE | <i>refFreqCSI-RS</i> IE in TS 38.331 [22] | | +| 29039 | >>>>>>NR Serving Cell | STRUCTURE | | | <i>measResultServingCell</i> IE in TS 38.331 [22] | +| 29040 | >>>>>>>NR Neighbour Cell Measurement List | LIST | | | <i>measResultNeighbourCellListNR</i> IE in TS 38.331 [22] | +| 29041 | >>>>>>>>NR Neighbour Cell Measurement Item | STRUCTURE | | | <i>measResultNRItem</i> IE in TS 38.331 [22] | +| 29042 | >>>>>>>>NR Neighbour Cell | STRUCTURE | | <i>NR Cell</i> in 8.1.1.1 | | +| 29051 | >DRX Info MCG | STRUCTURE | | | <i>drx-InfoMCG</i> IE in TS 38.331 [22] | +| 29052 | >>DRX Long Cycle Start Offset | ELEMENT | FALSE | <i>drx-LongCycleStartOffset</i> IE in TS 38.331 [22] | | +| 29053 | >>Short DRX | STRUCTURE | | | <i>shortDRX</i> IE in TS 38.331 [22] | +| 29054 | >>>DRX Short Cycle | ELEMENT | FALSE | <i>drx-ShortCycle</i> IE in TS 38.331 [22] | | +| 29055 | >>>DRX Short Cycle Timer | ELEMENT | FALSE | <i>drx-ShortCycleTimer</i> IE in TS 38.331 [22] | | +| 29061 | >Measurement Configuration MN | STRUCTURE | | | <i>MeasConfigMN</i> IE in TS 38.331 [22] | +| 29062 | >>MN Measured Frequencies | LIST | | | <i>measuredFrequenciesMN</i> IE in TS 38.331 [22] | +| 29063 | >>>NR Frequency Info Item | STRUCTURE | | <i>NR-FreqInfo</i> IE in TS 38.331 [22] | | +| 29064 | >>>>NR ARFCN | ELEMENT | FALSE | <i>ARFCN-ValueNR</i> IE in TS 38.331 [22] | | +| 29065 | >Secondary Cell Group RB Config | STRUCTURE | | | <i>scg-RB-Config</i> IE in TS 38.331 [22] | +| 29066 | >>Radio Bearer Config | STRUCTURE | | | <i>RadioBearerConfig</i> IE in TS 38.331 [22] | +| 29067 | >>>DRB To Add Modify List | LIST | | | <i>Drb-ToAddModList</i> IE in TS 38.331 [22] | + +| | | | | | | +|-------|-----------------------------------|---------------|-------|-------------------------------------------------------------|-------------------------------------------------------| +| 29068 | >>>>DRB To Add Modify Item | STRUC<br>TURE | | | <i>DRB-ToAddMod</i><br>IE in TS 38.331<br>[22] | +| 29069 | >>>>>CHOICE <i>CN Association</i> | STRUC<br>TURE | | | <i>cnAssociation</i> IE<br>in TS 38.331 [22] | +| 29070 | >>>>>>EPS Bearer Identity | ELEME<br>NT | FALSE | <i>eps-<br/>BearerIdent<br/>ity</i> IE in TS<br>38.331 [22] | | +| 29071 | >>>>>>SDAP Config | STRUC<br>TURE | | | <i>SDAP-Config</i> IE<br>in TS 38.331 [22] | +| 29072 | >>>>>>>PDU Session ID | ELEME<br>NT | TRUE | <i>PDU-<br/>SessionID</i><br>IE in TS<br>38.331 [22] | | +| 29073 | >>>>>>>PDU Session | STRUC<br>TURE | | 8.1.1.16 | | +| 29074 | >>>>>>>Default DRB | ELEME<br>NT | FALSE | <i>defaultDRB</i><br>IE in TS<br>38.331 [22] | | +| 29075 | >>>>>DRB ID | ELEME<br>NT | TRUE | <i>DRB-<br/>Identity</i> IE<br>in TS<br>38.331 [22] | | +| 29076 | >>>>>CHOICE <i>DRB Type</i> | STRUC<br>TURE | | | <i>DRB-ToAddMod</i><br>IE in TS 38.331<br>[22] | +| 29077 | >>>>>>NG-RAN DRB | STRUC<br>TURE | | 8.1.1.5 | | +| 29078 | >>>>>>LTE E-UTRA DRB | STRUC<br>TURE | | 8.1.1.9 | | +| 29079 | >>>>>Reestablish PDCP | ELEME<br>NT | FALSE | <i>reestablish<br/>PDCP</i> IE in<br>TS 38.331<br>[22] | | +| 29080 | >>>>>Recover PDCP | ELEME<br>NT | FALSE | <i>recoverPD<br/>CP</i> IE in TS<br>38.331 [22] | | +| 29081 | >>>>>PDCP Config | STRUC<br>TURE | | <i>PDCP<br/>Configurati<br/>on</i> IE in<br>8.1.2.2.4 | | +| 29091 | >Master Cell Group RB Config | STRUC<br>TURE | | | <i>scg-RB-Config</i> IE<br>in TS 38.331 [22] | +| 29092 | >>Radio Bearer Config | STRUC<br>TURE | | | <i>RadioBearerConf<br/>ig</i> IE in TS<br>38.331 [22] | +| 29093 | >>>DRB To Add Modify List | LIST | | | <i>Drb-<br/>ToAddModList</i> IE<br>in TS 38.331 [22] | +| 29094 | >>>>DRB To Add Modify Item | STRUC<br>TURE | | | <i>DRB-ToAddMod</i><br>IE in TS 38.331<br>[22] | +| 29095 | >>>>>CHOICE <i>CN Association</i> | STRUC<br>TURE | | | <i>cnAssociation</i> IE<br>in TS 38.331 [22] | +| 29096 | >>>>>>EPS Bearer Identity | ELEME<br>NT | FALSE | <i>eps-<br/>BearerIdent<br/>ity</i> IE in TS<br>38.331 [22] | | +| 29097 | >>>>>>SDAP Config | STRUC<br>TURE | | | <i>SDAP-Config</i> IE<br>in TS 38.331 [22] | +| 29098 | >>>>>>>PDU Session ID | ELEME<br>NT | FALSE | <i>PDU-<br/>SessionID</i><br>IE in TS<br>38.331 [22] | | +| 29099 | >>>>>>>PDU Session | STRUC<br>TURE | | 8.1.1.16 | | + +| | | | | | | +|-------|---------------------------------------|-----------|-------|----------------------------------------------|------------------------------------------------------------| +| 29100 | >>>>>>Default DRB | ELEMENT | FALSE | <i>defaultDRB</i> IE in TS 38.331 [22] | | +| 29101 | >>>>>>Reflective QoS | ELEMENT | FALSE | <i>as-reflectiveQoS</i> IE in TS 38.331 [22] | | +| 29102 | >>>>>DRB ID | ELEMENT | TRUE | <i>DRB-Identity</i> IE in TS 38.331 [22] | | +| 29103 | >>>>>CHOICE <i>DRB Type</i> | STRUCTURE | | | <i>DRB-ToAddMod</i> IE in TS 38.331 [22] | +| 29104 | >>>>>NG-RAN DRB | STRUCTURE | | 8.1.1.5 | | +| 29105 | >>>>>LTE E-UTRA DRB | STRUCTURE | | 8.1.1.9 | | +| 29106 | >>>>>Reestablish PDCP | ELEMENT | FALSE | <i>reestablishPDCP</i> IE in TS 38.331 [22] | | +| 29107 | >>>>>Recover PDCP | ELEMENT | FALSE | <i>recoverPDCP</i> IE in TS 38.331 [22] | | +| 29108 | >>>>>PDCP Config | STRUCTURE | | <i>PDCP Configuration</i> IE in 8.1.2.2.4 | | +| 29111 | >List of UE Capability RAT Containers | LIST | | | <i>UE-CapabilityRAT-ContainerList</i> IE in TS 38.331 [22] | +| 29112 | >>UE Capability RAT Container Item | STRUCTURE | | | <i>UE-CapabilityRAT-Container</i> IE in TS 38.331 [22] | +| 29113 | >>>RAT Type | ELEMENT | FALSE | <i>RAT-Type</i> IE in TS 38.331 [22] | | + +#### 8.1.2.5.2 RRC Cell Group Config Transfer + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------------------|--------------------------|----------|----------------------------------------------------|----------------------------------------------------| +| 29501 | CellGroupConfig | STRUCTURE | | | TS 38.473 [19] clause 9.3.1.25 | +| 29502 | >Cell Group ID | STRUCTURE | | 8.1.1.7 | | +| 29503 | >List of RLC Bearers to Add or Modify | LIST | | | <i>rlc-BearerToAddModList</i> IE in TS 38.331 [22] | +| 29504 | >>RLC Bearer to Add or Modify Item | STRUCTURE | | | <i>rlc-BearerToAddModList</i> IE in TS 38.331 [22] | +| 29505 | >>>Served RLC Radio Bearer | STRUCTURE | | 8.1.1.5 | | +| 29506 | >>>RLC Bearer Config | STRUCTURE | | | <i>RLC-BearerConfig</i> IE in TS 38.331 [22] | +| 29507 | >>>>Logical Channel Identity | ELEMENT | TRUE | <i>logicalChannelIdentity</i> IE in TS 38.331 [22] | | +| 29508 | >>>>Reestablish RLC | ELEMENT | FALSE | <i>reestablishRLC</i> IE in TS 38.331 [22] | | +| 29509 | >>>>CHOICE <i>RLC Config</i> | STRUCTURE | | | <i>RLC-Config</i> IE in TS 38.331 [22] | +| 29510 | >>>>>AM | STRUCTURE | | | <i>am</i> IE in TS 38.331 [22] | +| 29511 | >>>>>>UL AM RLC | STRUCTURE | | | <i>ul-AM-RLC</i> IE in TS 38.331 [22] | +| 29512 | >>>>>>>Poll Retransmit | ELEMENT | FALSE | <i>t-PollRetransmit</i> IE in TS 38.331 [22] | | +| 29513 | >>>>>>>Max Retransmission Threshold | ELEMENT | FALSE | <i>maxRetxThreshold</i> IE in TS 38.331 [22] | | +| 29514 | >>>>>>>Poll PDU | ELEMENT | FALSE | <i>pollPDU</i> IE in TS 38.331 [22] | | +| 29515 | >>>>>>>Poll Byte | ELEMENT | FALSE | <i>pollByte</i> IE in TS 38.331 [22] | | +| 29516 | >>>>>>>DL AM RLC | STRUCTURE | | | <i>dl-AM-RLC</i> IE in TS 38.331 [22] | +| 29517 | >>>>>>>Reassembly | ELEMENT | FALSE | <i>t-Reassembly</i> IE in TS 38.331 [22] | | +| 29518 | >>>>>>>Status Prohibit | ELEMENT | FALSE | <i>t-StatusProhibit</i> IE in TS 38.331 [22] | | +| 29519 | >>>>>UM Bi-directional | STRUCTURE | | | <i>um-Bi-Directional</i> IE in TS 38.331 [22] | +| 29521 | >>>>>>UL UM RLC | ELEMENT | FALSE | | <i>UL-UM-RLC</i> IE in TS 38.331 [22] | +| 29522 | >>>>>>DL UM RLC | STRUCTURE | | | <i>DL-UM-RLC</i> IE | + +| | | | | | | +|-------|------------------------------------------|-----------|-------|-----------------------------------------------------------------|------------------------------------------------------| +| | | | | | in TS 38.331 [22] | +| 29523 | >>>>>>Reassembly | ELEMENT | FALSE | <i>t-Reassembly</i> IE in TS 38.331 [22] | | +| 29530 | >>>>>UM Uni-directional UL | STRUCTURE | | | <i>um-Uni-Directional-UL</i> IE in TS 38.331 [22] | +| 29531 | >>>>>>UL UM RLC | ELEMENT | FALSE | <i>ul-UM-RLC</i> IE in TS 38.331 [22] | | +| 29540 | >>>>>UM Uni-directional DL | STRUCTURE | | | <i>um-Uni-Directional-DL</i> IE in TS 38.331 [22] | +| 29541 | >>>>>>DL UM RLC | STRUCTURE | | | <i>dl-UM-RLC</i> IE in TS 38.331 [22] | +| 29542 | >>>>>>Reassembly | ELEMENT | FALSE | <i>t-Reassembly</i> IE in TS 38.331 [22] | | +| 29551 | >>>>MAC Logical Channel Config | STRUCTURE | | | | +| 29552 | >>>>>Priority | ELEMENT | FALSE | <i>priority</i> IE in TS 38.331 [22] Clause 6 | | +| 29553 | >>>>>Prioritized Bit Rate | ELEMENT | FALSE | <i>prioritisedBitRate</i> IE in TS 38.331 [22] Clause 6 | | +| 29554 | >>>>>Bucket Size Duration | ELEMENT | FALSE | <i>bucketSizeDuration</i> IE in TS 38.331 [22] Clause 6 | | +| 29555 | >>>>>List of allowed sub-carrier spacing | LIST | | | <i>allowedSCS-List</i> IE in TS 38.331 [22] Clause 6 | +| 29556 | >>>>>>Allowed sub-carrier spacing item | STRUCTURE | | | | +| 29557 | >>>>>>>Sub Carrier Spacing | ELEMENT | FALSE | <i>SubCarrierSpacing</i> IE in TS 38.331 [22] Clause 6 | | +| 29558 | >>>>>Max PUSCH Duration | ELEMENT | FALSE | <i>maxPUSCH-Duration</i> IE in TS 38.331 [22] Sec 6 | | +| 29559 | >>>>>Configured Grant Type1 Allowed | ELEMENT | | <i>configuredGrantTypeAllowed</i> IE in TS 38.331 [22] Clause 6 | | +| 29560 | >>>>>Logical Channel Group | ELEMENT | FALSE | <i>logicalChannelGroup</i> IE in TS 38.331 [22] | | +| 29561 | >>>>>Logical Channel SR – Mask | ELEMENT | FALSE | <i>logicalChannelSR-Mask</i> IE in TS | | + +| | | | | | | +|-------|----------------------------------------------------|-----------|-------|--------------------------------------------------------------------------------------------|-------------------------------------------------------------------------| +| | | | | 38.331 [22]<br>Clause 6 | | +| 29562 | >>>>>Logical Channel SR –<br>Delay Timer Applied | ELEMENT | FALSE | <i>logicalChann<br/>elSR-<br/>DelayTimerA<br/>ppplied</i> IE in<br>TS 38.331<br>[22] Sec 6 | | +| 29563 | >>>>>Bit Rate Query Prohibit<br>Timer | ELEMENT | FALSE | <i>bitRateQuer<br/>yProhibitTim<br/>er</i> IE in TS<br>38.331 [22]<br>Clause 6 | | +| 29564 | >>>>>Channel Access<br>Priority | ELEMENT | FALSE | <i>reestablishR<br/>LC</i> IE in TS<br>38.331 [22] | | +| 29565 | >>>>>Bit Rate Multiplier | ELEMENT | FALSE | <i>logicalChann<br/>elGroup</i> IE<br>in TS 38.331<br>[22] | | +| 29601 | >List of RLC Bearers to Release | LIST | | | <i>rlc-<br/>BearerToRelea<br/>seList</i> IE in TS<br>38.331 [22] | +| 29602 | >>RLC Bearer to Release Item | STRUCTURE | | | <i>rlc-<br/>BearerToRelea<br/>seList</i> IE in TS<br>38.331 [22] | +| 29603 | >>>Served RLC Radio Bearer | STRUCTURE | | 8.1.1.5 | | +| 29604 | >>>Logical Channel Identity | ELEMENT | TRUE | <i>logicalChann<br/>elIdentity</i> IE<br>in TS 38.331<br>[22] | | +| 29651 | >MAC Cell Group Config | STRUCTURE | | | <i>mac-<br/>CellGroupConf<br/>ig</i> IE in TS<br>38.331 [22] | +| 29652 | >>Scheduling Request Config | STRUCTURE | | | <i>schedulingReq<br/>uestConfig</i> IE<br>in TS 38.331<br>[22] | +| 29654 | >>>List of Scheduling Requests to<br>Add or Modify | LIST | | | <i>schedulingReq<br/>uestToAddMod<br/>List</i> IE in TS<br>38.331 [22] | +| 29655 | >>>>Scheduling Request Item | STRUCTURE | | | <i>SchedulingReq<br/>uestToAddMod</i><br>IE in TS<br>38.331 [22] | +| 29656 | >>>>>Scheduling Request ID | ELEMENT | TRUE | <i>SchedulingR<br/>equestId</i> IE<br>in TS 38.331<br>[22] | | +| 29657 | >>>>>SR Prohibit Timer | ELEMENT | FALSE | <i>sr-<br/>ProhibitTime<br/>r</i> IE in TS<br>38.331 [22] | | +| 29658 | >>>>>SR Transmission Max | ELEMENT | FALSE | <i>sr-TransMax</i><br>IE in TS<br>38.331 [22] | | +| 29659 | >>>List of Scheduling Requests for<br>release | LIST | | | <i>schedulingReq<br/>uestToRelease<br/>List</i> IE in TS<br>38.331 [22] | +| 29660 | >>>>Scheduling Request Item | STRUCTURE | | | | +| 29661 | >>>>>Scheduling Request ID | ELEMENT | TRUE | <i>SchedulingR<br/>equestId</i> IE | | + +| | | | | | | +|-------|-----------------------------------|-----------|-------|---------------------------------------------------------|----------------------------------------| +| | | | | in TS 38.331 [22] | | +| 29662 | >>>>>SR Prohibit Timer | ELEMENT | FALSE | <i>sr-ProhibitTimer</i> IE in TS 38.331 [22] | | +| 29663 | >>>>>SR Transmission Max | ELEMENT | FALSE | <i>sr-TransMax</i> IE in TS 38.331 [22] | | +| 29675 | >>BSR Config | STRUCTURE | | | <i>bsr-Config</i> IE in TS 38.331 [22] | +| 29676 | >>>Periodic BSR Timer | ELEMENT | FALSE | <i>periodicBSR-Timer</i> IE in TS 38.331 [22] | | +| 29677 | >>>Retx BSR Timer | ELEMENT | FALSE | <i>retxBSR-Timer</i> IE in TS 38.331 [22] | | +| 29578 | >>>Logical Channel SR Delay Timer | ELEMENT | FALSE | <i>logicalChannelSR-DelayTimer</i> IE in TS 38.331 [22] | | + +### 8.1.2.5.3 RRC Measurement Configuration + +This Call Process Breakpoint uses RRC related RAN parameters defined in clauses 8.1.1 and 8.4.10. + +### 8.1.2.6 PDU Session Management + +The RAN Parameters for the call process type of “PDU Session Management” are defined as follows. + +#### 8.1.2.6.1 PDU Session Resource Setup + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------------|--------------------------|----------|----------------------------------------------------------------------|--------------------------------------------------------------------------| +| 30001 | PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.413 [11] Clause 9.3.1.50 | | +| 30002 | PDU Session | STRUCTURE | | 8.1.1.16 | | +| 30003 | List of QoS Flows to be setup | LIST | | | <i>QoS Flow Setup Request List</i> IE in TS 38.413 [11] Clause 9.3.4.1 | +| 30004 | >QoS flow setup request item | STRUCTURE | | | <i>QoS Flow Setup Request Item</i> IE in TS 38.413 [11] Clause 9.3.4.1 | +| 30005 | >>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.413 [11] Clause 9.3.1.51 | | +| 30006 | >>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 30010 | List of QoS Flows failed to be setup | LIST | | | <i>QoS Flow Failed To Setup List</i> IE in TS 38.413 [11] Clause 9.3.4.2 | +| 30011 | >QoS flow item failed for setup | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 38.413 [11] Clause 9.3.1.13 | +| 30012 | >>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.413 [11] Clause 9.3.1.51 | | +| 30013 | >>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 30014 | >>Cause | STRUCTURE | | | <i>Cause</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 30015 | >>>CHOICE <i>Cause group</i> | STRUCTURE | | | <i>Cause Group</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 30016 | >>>>Radio Network Layer | STRUCTURE | | | <i>Radio Network Layer</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 30017 | >>>>>Radio Network Layer Cause | ELEMENT | FALSE | <i>Radio Network Layer Cause</i> IE in TS 38.413 [11] Clause 9.3.1.2 | | +| 30018 | >>>>Transport Layer | STRUCTURE | | | <i>Transport</i> | + +| | | | | | | +|-------|-----------------------------|-----------|-------|------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | | <i>Layer IE in TS 38.413 [11] Clause 9.3.1.2</i> | +| 30019 | >>>>>Transport Layer Cause | ELEMENT | FALSE | <i>Transport Layer Cause IE in TS 37.483 [21] Clause 9.3.1.2</i> | | +| 30020 | >>>>NAS | STRUCTURE | | | <i>NAS IE in TS 38.413 [11] Clause 9.3.1.2</i> | +| 30021 | >>>>>NAS Cause | ELEMENT | FALSE | <i>NAS Cause IE in TS 38.413 [11] Clause 9.3.1.2</i> | | +| 30022 | >>>>Protocol | STRUCTURE | | | <i>Protocol IE in TS 38.413 [11] Clause 9.3.1.2</i> | +| 30023 | >>>>>Protocol Cause | ELEMENT | FALSE | <i>Protocol Cause IE in TS 38.413 [11] Clause 9.3.1.2</i> | | +| 30024 | >>>>Miscellaneous | STRUCTURE | | | <i>Misc IE in TS 38.413 [11] Clause 9.3.1.2</i> | +| 30025 | >>>>>Miscellaneous Cause | ELEMENT | FALSE | <i>Miscellaneous Cause IE in TS 38.413 [11] Clause 9.3.1.2</i> | | +| 30031 | Primary Cell ID | STRUCTURE | | | This is for the primary serving cell of the UE. The structuring of this parameter is based on <i>Target Cell Global ID IE</i> in TS 38.423 [15] clause 9.2.3.25 | +| 30032 | >CHOICE <i>Primary Cell</i> | STRUCTURE | | | The primary cell could either be an NR primary cell or an LTE primary cell. The structuring is based on <i>Target Cell IE</i> in TS 38.423 [15] clause 9.2.3.25 | +| 30033 | >>NR SpCell | STRUCTURE | | 8.1.1.1 | <i>NR Cell IE</i> in TS 38.423 [15] clause 9.2.3.25 | +| 30034 | >>E-UTRA PCell | STRUCTURE | | 8.1.1.2 | <i>E-UTRA Cell IE</i> in TS 38.423 [15] | + +| | | | | | | +|--|--|--|--|--|--------------------| +| | | | | | clause<br>9.2.3.25 | +|--|--|--|--|--|--------------------| + +#### 8.1.2.6.2 PDU Session Resource Modification + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------------------------|--------------------------|----------|----------------------------------------------------------------------|----------------------------------------------------------------------------------| +| 31001 | PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.413 [11] Clause 9.3.1.50 | | +| 31002 | PDU Session | STRUCTURE | | 8.1.1.16 | | +| 31003 | List of QoS Flows to add or modify | LIST | | | <i>QoS Flow Add or Modify Request List IE</i> in TS 38.413 [11] Clause 9.3.4.3 | +| 31004 | >QoS flow add or modify request item | STRUCTURE | | | <i>QoS Flow Add or Modify Request Item IE</i> in TS 38.413 [11] Clause 9.3.4.3 | +| 31005 | >QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.413 [11] Clause 9.3.1.51 | | +| 31006 | >>QoS flow | STRUCTURE | | 8.1.1.6 | | +| | | | | | | +| 31012 | List of QoS Flows failed to be added or modified | LIST | | | <i>QoS Flow Failed To Add or Modify List IE</i> in TS 38.413 [11] Clause 9.3.4.2 | +| 31013 | >QoS flow item failed to be added or modified | STRUCTURE | | | <i>QoS Flow Item IE</i> in TS 38.413 [11] Clause 9.3.1.13 | +| 31014 | >>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.413 [11] Clause 9.3.1.51 | | +| 31015 | >>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 31016 | >>Cause | STRUCTURE | | | <i>Cause</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 31017 | >>>CHOICE <i>Cause group</i> | STRUCTURE | | | <i>Cause Group</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 31018 | >>>>Radio Network Layer | STRUCTURE | | | <i>Radio Network Layer</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 31019 | >>>>>Radio Network Layer Cause | ELEMENT | FALSE | <i>Radio Network Layer Cause</i> IE in TS 38.413 [11] Clause 9.3.1.2 | | +| 31020 | >>>>Transport Layer | STRUCTURE | | | <i>Transport Layer</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 31021 | >>>>>Transport Layer Cause | ELEMENT | FALSE | <i>Transport Layer Cause</i> IE in TS 37.483 [21] Clause 9.3.1.2 | | +| 31022 | >>>>NAS | STRUCTURE | | | <i>NAS</i> IE in TS | + +| | | | | | | +|-------|----------------------------------|-----------|-------|-------------------------------------------------------------------------|------------------------------------------------------------------------| +| | | | | | 38.413 [11]<br>Clause 9.3.1.2 | +| 31023 | >>>>>NAS Cause | ELEMENT | FALSE | <i>NAS Cause</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | | +| 31024 | >>>>Protocol | STRUCTURE | | | <i>Protocol</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | +| 31025 | >>>>>Protocol Cause | ELEMENT | FALSE | <i>Protocol Cause</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | | +| 31026 | >>>>Miscellaneous | STRUCTURE | | | <i>Misc</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | +| 31027 | >>>>>Miscellaneous Cause | ELEMENT | FALSE | <i>Miscellaneous Cause</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | | +| 31031 | List of QoS Flows to be released | LIST | | | <i>QoS Flow To Release List</i> IE in TS 38.413 [11]<br>Clause 9.3.4.2 | +| 31032 | >QoS flow item to be released | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 38.413 [11]<br>Clause 9.3.1.13 | +| 31033 | >>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.413 [11]<br>Clause 9.3.1.51 | | +| 31034 | >>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 31035 | >>Cause | STRUCTURE | | | <i>Cause</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | +| 31036 | >>>CHOICE <i>Cause group</i> | STRUCTURE | | | <i>Cause Group</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | +| 31037 | >>>>Radio Network Layer | STRUCTURE | | | <i>Radio Network Layer</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | +| 31038 | >>>>>Radio Network Layer Cause | ELEMENT | | <i>Radio Network Layer Cause</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | | +| 31039 | >>>>Transport Layer | STRUCTURE | | | <i>Transport Layer</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | +| 31040 | >>>>>Transport Layer Cause | ELEMENT | FALSE | <i>Transport Layer Cause</i> IE in TS 37.483 [21]<br>Clause 9.3.1.2 | | +| 31041 | >>>>NAS | STRUCTURE | | | <i>NAS</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | +| 31042 | >>>>>NAS Cause | ELEMENT | FALSE | <i>NAS Cause</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | | +| 31043 | >>>>Protocol | STRUCTURE | | | <i>Protocol</i> IE in TS 38.413 [11]<br>Clause 9.3.1.2 | +| 31044 | >>>>>Protocol Cause | ELEMENT | FALSE | <i>Protocol Cause</i> | | + +| | | | | | | +|-------|--------------------------------|-----------|-------|-----------------------------------------------------------------|--------------------------------------------------------------------------| +| | | | | IE in TS 38.413 [11] Clause 9.3.1.2 | | +| 31045 | >>>>Miscellaneous | STRUCTURE | | | <i>Misc IE in TS 38.413 [11] Clause 9.3.1.2</i> | +| 31046 | >>>>>Miscellaneous Cause | ELEMENT | FALSE | <i>Miscellaneous Cause IE in TS 38.413 [11] Clause 9.3.1.2</i> | | +| 31051 | MR-DC Usage Information | STRUCTURE | | | <i>MR-DC Usage Information IE in TS 37.483 [21] Clause 9.3.1.63</i> | +| 31052 | >Secondary RAT Type | ELEMENT | FALSE | <i>Secondary RAT Type IE in TS 37.483 [21] Clause 9.3.1.63</i> | | +| 31053 | >PDU Session Timed Report List | LIST | | | <i>Data Usage Report List IE in TS 37.483 [21] Clause 9.3.1.64</i> | +| 31054 | >>MR-DC Data Usage Report Item | STRUCTURE | | | <i>Data Report Usage Item IE in TS 37.483 [21] Clause 9.3.1.64</i> | +| 31055 | >>>Start Timestamp | ELEMENT | FALSE | <i>Start timestamp IE in TS 37.483 [21] Clause 9.3.1.64</i> | | +| 31075 | >>>End Timestamp | ELEMENT | FALSE | <i>End timestamp IE in TS 37.483 [21] Clause 9.3.1.64</i> | | +| 31056 | >>>Usage Count UL | ELEMENT | FALSE | <i>Usage count DL IE in TS 37.483 [21] Clause 9.3.1.64</i> | | +| 31057 | >>>Usage Count DL | ELEMENT | FALSE | <i>Usage count DL IE in TS 37.483 [21] Clause 9.3.1.64</i> | | +| 31061 | MR-DC Usage for QoS flows | LIST | | | <i>Data Usage Per QoS Flow List IE in TS 37.483 [21] Clause 9.3.1.63</i> | +| 31062 | >QoS Flow Item | STRUCTURE | | | <i>Data Usage Per QoS Flow Item IE in TS 37.483 [21] Clause 9.3.1.63</i> | +| 31063 | >>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier IE in TS 37.483 [21] Clause 9.3.1.24</i> | | +| 31064 | >>Secondary RAT Type | ELEMENT | FALSE | <i>Secondary RAT Type IE in TS 37.483 [21] Sec 9.3.1.63</i> | | +| 31065 | >>QoS Flow Timed Report List | LIST | | | <i>Data Usage Report List IE in TS 37.483 [21] Clause</i> | + +| | | | | | | +|-------|---------------------------------|-----------|-------|-------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | | 9.3.1.64 | +| 31066 | >>>MR-DC Data Usage Report Item | STRUCTURE | | | <i>Data Report Usage Item</i> IE in TS 37.483 [21] Clause 9.3.1.64 | +| 31067 | >>>>Start Timestamp | ELEMENT | FALSE | <i>Start timestamp</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 31068 | >>>>End timestamp | ELEMENT | FALSE | <i>End timestamp</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 31069 | >>>>Usage Count UL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 31070 | >>>>Usage Count DL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 31081 | Primary Cell ID | STRUCTURE | | | This is for the primary serving cell of the UE. The structuring of this parameter is based on <i>Target Cell Global ID</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 31082 | >CHOICE Primary Cell | STRUCTURE | | | The primary cell could either be an NR primary cell or an LTE primary cell. The structuring is based on <i>Target Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 31083 | >>NR SpCell | STRUCTURE | | 8.1.1.1 | <i>NR Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 31084 | >>E-UTRA PCell | STRUCTURE | | 8.1.1.2 | <i>E-UTRA Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | + +### 8.1.2.6.3 PDU Session Resource Release + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------------|--------------------------|----------|----------------------------------------------------------------------|---------------------------------------------------------------------| +| 32001 | PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.413 [11] Clause 9.3.1.50 | | +| 32002 | PDU Session | STRUCTURE | | 8.1.1.16 | | +| 32011 | Cause | STRUCTURE | | | <i>Cause</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 32012 | >CHOICE <i>Cause group</i> | STRUCTURE | | | <i>Cause Group</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 32013 | >>Radio Network Layer | STRUCTURE | | | <i>Radio Network Layer</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 32014 | >>>Radio Network Layer Cause | ELEMENT | FALSE | <i>Radio Network Layer Cause</i> IE in TS 38.413 [11] Clause 9.3.1.2 | | +| 32015 | >>Transport Layer | STRUCTURE | | | <i>Transport Layer</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 32016 | >>>Transport Layer Cause | ELEMENT | FALSE | <i>Transport Layer Cause</i> IE in TS 37.483 [21] Clause 9.3.1.2 | | +| 32017 | >>NAS | STRUCTURE | | | <i>NAS</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 32018 | >>>NAS Cause | ELEMENT | FALSE | <i>NAS Cause</i> IE in TS 38.413 [11] Clause 9.3.1.2 | | +| 32019 | >>Protocol | STRUCTURE | | | <i>Protocol</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 32020 | >>>Protocol Cause | ELEMENT | FALSE | <i>Protocol Cause</i> IE in TS 38.413 [11] Clause 9.3.1.2 | | +| 32021 | >>Miscellaneous | STRUCTURE | | | <i>Misc</i> IE in TS 38.413 [11] Clause 9.3.1.2 | +| 32022 | >>>Miscellaneous Cause | ELEMENT | FALSE | <i>Miscellaneous Cause</i> IE in TS 38.413 [11] Clause 9.3.1.2 | | +| 32031 | MR-DC Usage Information | STRUCTURE | | | <i>MR-DC Usage Information</i> IE in TS 37.483 [21] Clause 9.3.1.63 | +| 32032 | >Secondary RAT Type | ELEMENT | FALSE | <i>Secondary RAT Type</i> IE in TS | | + +| | | | | | | +|-------|---------------------------------|-----------|-------|----------------------------------------------------------------|--------------------------------------------------------------------------| +| | | | | 37.483 [21]<br>Clause 9.3.1.63 | | +| 32033 | >PDU Session Timed Report List | LIST | | | <i>Data Usage Report List</i> IE in TS 37.483 [21] Clause 9.3.1.64 | +| 32034 | >>MR-DC Data Usage Report Item | STRUCTURE | | | <i>Data Report Usage Item</i> IE in TS 37.483 [21] Clause 9.3.1.64 | +| 32035 | >>>Start Timestamp | ELEMENT | FALSE | <i>Start timestamp</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 32036 | >>>End Timestamp | ELEMENT | FALSE | <i>End timestamp</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 32037 | >>>Usage Count UL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 32038 | >>>Usage Count DL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 32041 | MR-DC Usage for QoS flows | LIST | | | <i>Data Usage Per QoS Flow List</i> IE in TS 37.483 [21] Clause 9.3.1.63 | +| 32042 | >QoS Flow Item | STRUCTURE | | | <i>Data Usage Per QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.63 | +| 32043 | >>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] Sec 9.3.1.24 | | +| 32054 | >>QoS flow | STRUCTURE | | 8.1.1.6 | | +| 32044 | >>Secondary RAT Type | ELEMENT | FALSE | <i>Secondary RAT Type</i> IE in TS 37.483 [21] Clause 9.3.1.63 | | +| 32045 | >>QoS Flow Timed Report List | LIST | | | <i>Data Usage Report List</i> IE in TS 37.483 [21] Clause 9.3.1.64 | +| 32046 | >>>MR-DC Data Usage Report Item | STRUCTURE | | | <i>Data Report Usage Item</i> IE in TS 37.483 [21] Clause 9.3.1.64 | +| 32047 | >>>>Start Timestamp | ELEMENT | FALSE | <i>Start timestamp</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 32048 | >>>>End timestamp | ELEMENT | FALSE | <i>End timestamp</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | + +| | | | | | | +|-------|----------------------|-----------|-------|------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 32049 | >>>>Usage Count UL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 32050 | >>>>Usage Count DL | ELEMENT | FALSE | <i>Usage count DL</i> IE in TS 37.483 [21] Clause 9.3.1.64 | | +| 32061 | Primary Cell ID | STRUCTURE | | | This is for the primary serving cell of the UE. The structuring of this parameter is based on <i>Target Cell Global ID</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 32062 | >CHOICE Primary Cell | STRUCTURE | | | The primary cell could either be an NR primary cell or an LTE primary cell. The structuring is based on <i>Target Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 32063 | >>NR SpCell | STRUCTURE | | 8.1.1.1 | <i>NR Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 32064 | >>E-UTRA PCell | STRUCTURE | | 8.1.1.2 | <i>E-UTRA Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | + +### 8.1.3 RAN Parameters for UE Identification + +The following RAN Parameters are defined for identification of UEs. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------|--------------------------|----------|---------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------| +| 35001 | Cell Global ID | STRUCTURE | | | To identify UEs associated to a specific cell | +| 35002 | >NR CGI | STRUCTURE | | | | +| 35003 | >>PLMN Identity | ELEMENT | FALSE | Defined in [4] clause 6.2.3.1. | | +| 35004 | >>NR Cell Identity | ELEMENT | FALSE | Defined in [4] clause 6.2.3.7. | | +| 35005 | >E-UTRA CGI | STRUCTURE | | | | +| 35006 | >>PLMN Identity | ELEMENT | FALSE | Defined in [4] clause 6.2.3.1. | | +| 35007 | >>E-UTRA Cell Identity | ELEMENT | FALSE | Defined in [4] clause 6.2.3.11. | | +| 35010 | S-NSSAI | STRUCTURE | | | To identify UEs associated to a specific S-NSSAI | +| 35011 | >SST | ELEMENT | FALSE | Defined in [4] clause 6.2.3.12. | | +| 35012 | >SD | ELEMENT | FALSE | Defined in [4] clause 6.2.3.12. | | +| 35020 | Group ID | STRUCTURE | | | To identify UEs associated to a specific Group ID defined in [4] clause 6.2.2.7. | +| 35021 | >IRFSP | ELEMENT | FALSE | Defined in [4] clause 6.2.3.27. | | +| 35022 | >SPID | ELEMENT | FALSE | Defined in [4] clause 6.2.3.28. | | +| 35030 | Explicit UE List ID | ELEMENT | FALSE | Defined in Clause 8.4.9.1. | To identify UEs associated to a specific Explicit UE List ID defined in Clause 8.4.9.1. | +| 35040 | Core Control Plane ID | STRUCTURE | | | To identify UEs associated to a specific Core Control Plane ID (GUAMI/GUMMEI) defined in [4] clause 6.2.2.8. | +| 35041 | >GUAMI | STRUCTURE | | | | +| 35042 | >>PLMN Identity | ELEMENT | FALSE | Defined in [4] clause 6.2.3.1. | | +| 35043 | >>AMF Region ID | ELEMENT | FALSE | Defined in [4] clause 6.2.3.17. | | +| 35044 | >>AMF Set ID | ELEMENT | FALSE | Defined in [4] clause 6.2.3.17. | | +| 35045 | >>AMF Pointer | ELEMENT | FALSE | Defined in [4] clause 6.2.3.17. | | +| 35046 | >GUMMEI | STRUCTURE | | | | +| 35047 | >>PLMN Identity | ELEMENT | FALSE | Defined in [4] clause 6.2.3.1. | | +| 35048 | >>MME Group ID | ELEMENT | FALSE | Defined in [4] clause 6.2.3.18. | | +| 35049 | >>MME Code | ELEMENT | FALSE | Defined in [4] clause 6.2.3.18. | | +| 35050 | QoS ID | STRUCTURE | | | To identify UEs associated to a specific QoS (QCI/5QI) defined in [4] clause 6.2.2.9. The criteria is for any EPS/PDU sessions assigned to a UE. | +| 35051 | >5QI | ELEMENT | FALSE | Defined in [4] clause 6.2.3.13. | | +| 35052 | >QCI | ELEMENT | FALSE | Defined in [4] clause 6.2.3.14. | | + +| | | | | | | +|-------|----------------------------------|---------|-------|--------------------------------|-------------------------------------------------------------------------------------------------------------| +| 35061 | UE Throughput (DL) | ELEMENT | FALSE | INTEGER | To identify UEs based on Average Total DL Thoughtput (kbit/s) as defined in TS 28.552 [28] clause 5.1.1.3.1 | +| 35062 | UE Throughput (UL) | ELEMENT | FALSE | INTEGER | To identify UEs based on Average Total UL Thoughtput (kbit/s) as defined in TS 28.552 [28] clause 5.1.1.3.3 | +| 35070 | Beam ID | ELEMENT | FALSE | Defined in [4] clause 6.2.2.16 | The serving SSB “beam” of the UE | +| 35080 | Explicit UE List assignment list | LIST | | | To provide a list of Explicit UE List ID matching condition | +| 35081 | > Explicit UE list ID | ELEMENT | FALSE | Defined in clause 8.4.9.1. | | +| 35090 | UE ID list | LIST | | | To provide a list of UE matching condition | +| 35091 | > UE ID | ELEMENT | FALSE | OCTET STRING | Defined in clause 9.3.10 | + +## 8.1.4 RAN Parameters for Cell Identification + +The following RAN Parameters are defined for identification of Cells. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------|--------------------------|----------|---------------------------------|----------------------------------------------| +| 36001 | PLMN Identity | ELEMENT | FALSE | Defined in [4] clause 6.2.3.1. | To identify cells based on PLMN ID | +| 36010 | S-NSSAI | STRUCTURE | | | To identify cells based on supported S-NSSAI | +| 36011 | >SST | ELEMENT | FALSE | Defined in [4] clause 6.2.3.12. | | +| 36012 | >SD | ELEMENT | FALSE | Defined in [4] clause 6.2.3.12. | | + +## 8.1.5 UE Events + +The following UE Event IDs are defined. + +| UE Event ID | UE Event Name | Message Event in E2SM-RC Event Trigger Definition Format 1 IE | If used in E2SM-RC Event Trigger Definition Format 1 IE | If used in E2SM-RC Indication Message Format 1 IE | +|-------------|---------------------------------|---------------------------------------------------------------|----------------------------------------------------------------------------------------|------------------------------------------------------------------------| +| 1 | Carrier Aggregation Initiated | “F1” Network Interface message of “UE Context Setup Request”. | Event triggering is only when this message event is by initiating carrier aggregation. | Indicates that this message event happened due to carrier aggregation. | +| 2 | A3 Measurement Report Reception | “RRC” message of “Measurement Report”. | Event triggering is only when this message event is by A3 event. | Indicates that this message event happened due to A3 event. | + +## 8.2 RAN parameters for REPORT services + +### 8.2.1 RAN Parameters for Report Service Style 1 + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------|--------------------------|----------|--------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | UE Event ID | ELEMENT | FALSE | INTEGER | This shall be used to report the related UE Event ID described in Clause 8.1.5. | +| 2 | NI Message | ELEMENT | FALSE | OCTET STRING | This shall be used to report Network Interface Message | +| 3 | RRC Message | ELEMENT | FALSE | OCTET STRING | This shall be used to report RRC Message | +| 4 | UE ID | ELEMENT | FALSE | OCTET STRING | Defined in Clause 9.3.10. This shall be used to report UE ID when the message event configured by the Event Trigger Style 1 is set to "RRC Setup Complete message" (UE attach), or "Xn/NG Handover Request" or "F1 UE Context Setup Request" (Intra gNB HandOver). | +| 5 | Old AMF UE NGAP ID | ELEMENT | FALSE | Defined in [4] clause 6.2.3.16. | This shall be used to report Old AMF UE NGAP ID when the message event configured by Event Trigger Style 1 is set to "Xn Handover Request" and AMF UE NGAP ID is changed during HO. | +| 6 | Cell Global ID | ELEMENT | FALSE | OCTET STRING | Defined in Clause 9.3.36<br>This shall be used to report the SpCell ID where the UE belongs to during reporting. | +| 7 | Beam ID | ELEMENT | FALSE | Defined in [4] clause 6.2.2.16 | This shall be used to report source beam (last serving beam in the source cell) ID when the message configured by the Event Trigger Style 1 is set to "Xn/X2 Failure Indication" or "Xn/X2 Handover Report" | +| 8 | UE Mobility Failure Cause | ELEMENT | FALSE | ENUMERATED (HO too early, HO too late, HO wrong cell, HO ping-pong, ...) | This shall be used to report Mobility failure root cause when the message configured by the Event Trigger Style 1 is set to "Xn/X2 Failure Indication" or "Xn/X2 Handover Report". | + +In addition, this report style may use RAN parameters defined in Clause 8.1.1. + +## 8.2.2 RAN Parameters for Report Service Style 2 + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------|----------------------------|----------|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Current UE ID | ELEMENT | FALSE | OCTET STRING | Defined in Clause 9.3.10. This shall be used to report UE ID defined at the time of Call Process Outcome. | +| 2 | Old UE ID | ELEMENT | FALSE | OCTET STRING | Defined in Clause 9.3.10. This shall be used to report the previously assigned UE ID prior to the call process. | +| 3 | Current RRC State | ELEMENT | FALSE | Defined in Clause 9.3.37. | This shall be used to report the RRC state at the time of Call Process Outcome. | +| 4 | Old RRC State | ELEMENT | FALSE | Defined in Clause 9.3.37. | This shall be used to report the previous RRC state prior to the Call Process Outcome. | +| 5 | UE Context Information Container | ELEMENT | FALSE | OCTET STRING | The RETRIEVE UE CONTEXT RESPONSE message content in TS 38.423 [17] clause 9.1.1.9. This shall be used to report UE Context information. | +| 6 | Cell Global ID | ELEMENT | FALSE | OCTET STRING | Defined in Clause 9.3.36<br>This shall be used to report the SpCell ID where the UE belongs to during reporting. | +| 7 | UE Information | Defined in Clause 8.1.1.17 | | | | + +## 8.2.3 RAN Parameters for Report Service Style 3 + +| RAN Parameter ID | RAN Parameter Name | Semantics Description | +|------------------|--------------------------|-----------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell Context Information | <i>Served Cell Information</i> IE in TS 38.473 [19] clause 9.3.1.10. This shall be used to report Cell Context information. | +| 2 | Cell Deleted | This shall be used to report deleted cells. The value shall be set to "True" | + +| | | | +|---|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------| +| | | for the deleted Cell Global ID. | +| 3 | Neighbour Relation Table | This shall be used to report neighbour relation information of the serving cells. | +| 4 | MIB | <i>MIB</i> IE in TS 38.331 [22] Clause 6.2.2. This shall be used to report MIB of the serving cell | +| 5 | Serving Cell Config Common | This shall be used to report common parameters of the serving cell contained in <i>ServingCellConfigCommon</i> IE in TS 38.331 [22] Clause 6.3.2. | + +## 8.2.4 RAN Parameters for Report Service Style 4 + +| RAN Parameter Category | RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------------|--------------------------------------------------------------------------------|----------------------|--------------------------|----------|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| PDCP UE Variables | Defined in Clause 8.1.1.8 L2 Bearer State Variables for PDCP State Variables | | | | | | +| RLC UM UE Variables | Defined in Clause 8.1.1.8 L2 Bearer State Variables for RLC UM State Variables | | | | | | +| RLC AM UE Variables | Defined in Clause 8.1.1.8 L2 Bearer State Variables for RLC AM State Variables | | | | | | +| MAC Variables | 100 | UL MAC CE | ELEMENT | FALSE | OCTET STRING | This shall be used to report MAC CE Structure as per TS 38.321 [26] clause 6.1.3 | +| | 101 | DL MAC CE | ELEMENT | FALSE | OCTET STRING | | +| | 102 | DL Buffer Occupancy | ELEMENT | FALSE | INTEGER | DL Buffer Occupancy at RLC. Expressed as absolute values in terms of Number of Kilo Bytes (KB) | +| RRC State | 201 | Current RRC State | ELEMENT | FALSE | Defined in Clause 9.3.37. | This shall be used to report the RRC state before RRC state change. | +| | 202 | RRC State Changed To | ELEMENT | FALSE | Defined in Clause 9.3.37. | This shall be used to report new RRC state upon RRC stage change | +| | 203 | RRC Message | ELEMENT | FALSE | OCTET STRING | This shall be used to report the RRC message which triggered RRC state change | +| UE Identifier Change | 300 | Old UE ID | ELEMENT | FALSE | OCTET STRING | Defined in Clause 9.3.10. This shall be used to report the old UE ID upon UE ID change E2 Node shall report any available old NI or RRC interface UE identifier within the UEID structure. | +| | 301 | Current UE ID | ELEMENT | FALSE | OCTET STRING | Defined in Clause 9.3.10. This shall be used to report the UE ID available at the time of reporting. | +| | 302 | NI Message | ELEMENT | FALSE | OCTET STRING | This shall be used to report the Network Interface message which triggered the UE ID change . | +| Cell Global ID | 400 | Cell Global ID | ELEMENT | FALSE | OCTET STRING | Defined in Clause 9.3.36. This shall be used to report the SpCell ID where the UE belongs to during reporting. | +| UE Context Info Change | Defined in Clause 8.1.1.17 UE Context Information related RAN parameters | | | | | | + +## 8.3 RAN parameters for INSERT services + +### 8.3.1 Approach + +The approach for RAN parameters associated with Insert service is provided in Clause 8.0. + +### 8.3.2 Radio Bearer Control request + +#### 8.3.2.1 DRB QoS Configuration request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.2.1. + +#### 8.3.2.2 QoS flow mapping configuration request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.2.2. + +#### 8.3.2.3 Logical channel configuration request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.2.3. + +#### 8.3.2.4 Radio Bearer Admission Control request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.2.4. + +#### 8.3.2.5 DRB Termination Control request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.2.5. + +#### 8.3.2.6 DRB Split Ratio Control request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.2.6. + +#### 8.3.2.7 PDCP Duplication Control request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.2.7. + +### 8.3.3 Radio Resource Allocation Control request + +#### 8.3.3.1 DRX Parameter Configuration request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.3.1. + +#### 8.3.3.2 Scheduling Request Parameter Configuration request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.3.2. + +#### 8.3.3.3 Semi-Persistent Scheduling Parameter Configuration request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.3.3. + +#### 8.3.3.4 Configured Grant Configuration request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.3.4. + +### **8.3.3.5 CQI table configuration request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.3.5. + +### **8.3.3.6 Slice-level PRB quota allocation request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.3.6. + +## **8.3.4 Connected Mode Mobility Control Request** + +### **8.3.4.1 Handover Control request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.4.1. + +### **8.3.4.2 Conditional Handover Control request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.4.2. + +### **8.3.4.3 DAPS Handover Control request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.4.3. + +## **8.3.5 Radio Access Control request** + +### **8.3.5.1 UE admission control request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.5.1. + +### **8.3.5.2 RACH backoff control request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.5.2. + +### **8.3.5.3 Access barring control request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.5.3. + +### **8.3.5.4 RRC Connection Release request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.5.4. + +### **8.3.5.5 RRC Connection Reject request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.5.5. + +## **8.3.6 Dual Connectivity Control request** + +### **8.3.6.1 DC Secondary Node Addition Control request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.6.1. + +### **8.3.6.2 DC Secondary Node Modification Control request** + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.6.2. + +### 8.3.6.3 PSCell Change cell for Secondary Cell Group Control request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.6.3. + +### 8.3.6.4 DC Secondary Node Change Control request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.6.4. + +## 8.3.7 Carrier Aggregation Control request + +### 8.3.7.1 Secondary cell Addition control request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.7.1. + +### 8.3.7.2 Secondary cell Modification control request + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.7.2. + +## 8.3.8 Idle Mode Mobility Control request + +### 8.3.8.1 Cell reselection priority control + +The RAN parameters associated with this Insert Indication are listed in Clause 8.4.8.1. + +## 8.3.9 Common RAN Parameters for INSERT Service styles + +The table below shows the set of RAN parameters that are common for all INSERT service styles. + +### 8.3.9.1 UE Context Information + +The associated RAN parameters are given in Clause 8.1.1.17. + +### 8.3.9.2 E2 Node Context Information + +The associated RAN parameters are given in Clause 8.1.1.11. + +## 8.3.10 Indication Semantics Description for interpretation by the RIC + +The E2 node requests the near-RT RIC for the following services as far as the radio bearer Control request is concerned. + +- (a) In the *RIC Indication Header* IE, the E2 node indicates the *Insert Indication* ID, that is associated with the *Insert Service Style* ID for the radio bearer control request, along with the UE ID, so as to enable the RIC to interpret which Insert Indication service pertaining to which UE is being requested by the E2 node. +- (b) In the *RIC Indication Message* IE, the E2 node indicates the list of the RAN parameters in the Indication message that it wants to be controlled by the near-RT RIC. If the E2 node does not provide values for these parameters in the *RIC Indication message* IE, then the RIC would set the values for these parameters in the control action sent via the *RIC Control Request* message, along with its decision to accept/deny the request raised by the E2 node (indicated in the *RIC Indication Header* IE). If the RAN parameter indicated by the E2 node is an ELEMENT, the RIC would set the value for the parameter in its *RIC Control Request* message. If the indicated RAN parameter is a STRUCTURE but if the E2 node does not list any constituent RAN parameter of the STRUCTURE, then the RIC would set the values for all the constituent RAN parameters of the STRUCTURE. If the parameter is a LIST, then: + - a. If the E2 node also indicates the *Key* RAN parameter pertaining to the itemized STRUCTURE in the LIST, then the RIC would set the values for all constituent RAN parameters within the structure, pointed by the key. + +- b. If the E2 node does not indicate the *Key* RAN parameter pertaining to the itemized STRUCTURE in the LIST, then the RIC would set the values for all constituent RAN parameters within each itemized STRUCTURE, whose *key* RAN parameter is identified by the RIC. +- (c) If the E2 node provides values for these parameters in the *RIC Indication message* IE, then the RIC would set the values only for those indicated parameters for which it would choose to replace the values already set by the E2 node. It also communicates its decision to accept/deny the request raised by the E2 node for the DRB. +- (d) Any RAN parameter identified as a *key* shall always carry a value set by the E2 node, if the E2 node expects the RIC to control the parameters pertaining to the STRUCTURE pointed by the E2 node. The value of this *key* RAN parameter is an index that points to the entire STRUCTURE, and hence the value of the *key* RAN parameter cannot be modified by the near-RT RIC. Without indicating the value for the *key* RAN parameter, the RIC would not control the parameters associated with the structure indexed by the *key*. + +Note that the RIC can only set the values for those RAN parameters identified as ELEMENT when they are indicated by the E2 node; however, these RAN parameters can be contained with a STRUCTURE or within an itemized STRUCTURE in a LIST. Also, if the *DRB ID* key parameter is not present for any DRB in the *RIC Indication Message* IE, then the RIC would discard the *RIC Indication message*. And the E2 node would have to set values based on its default radio resource management policies upon time out, and continue with the ongoing call processing. Hence, indicating the *DRB ID* IE for the DRB(s) is a pre-requisite for the RIC to act on the Insert indication via its *RIC Control Request* message. + +## 8.4 RAN Parameters for Control Actions + +### 8.4.1 Approach + +The approach for RAN parameters associated with Control service is provided in Clause 8.0. + +In the case of CONTROL action for UE group-based control (using E2SM-RC *Control Header Format 3* and E2SM-RC *Control Message Format 3*), since the control action can be applied as a whole on multiple UEs constituting the group, the RAN parameters, whose *key flag* value is set to “true”, shall not be used here, since they are only used for UE-specific entities. Instead, as provided in E2SM-RC *Control Message Format 3*, the *Entity Filter Definition* IE (from E2SM-RC *Control Message Format 3* in Clause 9.2.1.7.3) is used to define the entity filter and specify the corresponding set of filtering conditions towards determining the relevant entities (such as DRBs, QoS flows, etc.) pertaining to the UE group for which the control action is applicable. Each entity filter is identified by the *Entity Filter ID* IE. There may be more than one entity for the same UE group, whose associated RAN parameters can be controlled by the RIC using a single RIC CONTROL REQUEST message with the same *Control Action ID* IE. The control parameters, specific to a given set of entities, corresponding to the *Entity Filter ID* IE, are assigned values by the RIC. The list of all entity filters for the UE group are mentioned in *List of entity filters* IE. The control parameters are identified by the *List of RAN control Parameters for the matching entities* IE in E2SM-RC *Control Message Format 3* (in Clause 9.2.1.7.3) and correspond to each *Entity Filter ID* IE. The control action is then applied (based on the approach in Clause 8.0) individually on all the applicable entities (e.g., all the applicable DRBs) pertaining to the UE group, subject to the filtering criteria. + +For e.g., if PDCP duplication needs to be activated on all DRBs corresponding to 5QI 82 for the URLLC slice (SST 2) and if the number of duplicate PDCP paths needs to be set to 3, then the *Entity Filter Definition* IE in E2SM-RC *Control Message Format 3* (Sec 9.2.1.7.3) can be used to specify conditions that can match all DRBs pertaining to the 5QI of 82, and the *List of RAN control parameters for the matching entities* IE can be used to indicate the PDCP duplication configuration parameters, which shall later be applied by the E2 node individually on all the applicable DRBs across the corresponding UEs of the URLLC slice that constitute the UE group. + +The UE group control action may also be entity-agnostic. That is, the control action may not pertain to specific entities of the UEs, but may apply to the UEs as a whole. The *List of entity filters* IE is therefore optional. + +As an example, if A3 offset needs to be set to 4 dB for all UEs with NR-CGI “xyz” as their primary SpCell, the control action in this case is entity-agnostic, as the control action shall be applied on all UEs with NR-CG “xyz” as their SpCell, irrespective of their entities. + +Thus, if the control action is entity agnostic, then the *List of entity filters* IE is not present and the *List of RAN control parameters* IE is used to indicate the control parameters for the control action applied on the UE group. + +In the *E2SM-RC Control Header Format 3* IE shown in Clause 9.2.1.6.3, the *UE Group ID* IE and the *UE Group Definition* IE are used to uniquely identify and define the logical grouping of the UEs based on the list of RAN parameters from Clause 8.1.3, respectively. The *RIC Style Type* IE is used to refer to the RIC Control Service Style type and the *Control Action ID* IE is used to refer to a given control action within the RIC Control Service Style type. + +## 8.4.2 Radio Bearer Control + +### 8.4.2.1 DRB QoS Configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to DRB QoS Configuration, such as *Bearer Context Management*, *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *DRB ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +In the case of UE group-based control action, where the relevant entities include more than one DRB subject to QoS configuration, the above procedures are individually invoked for each applicable DRB pertaining to each individual UE of the group. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------|--------------------------|----------|-----------------------------------------------------------------------------------|--------------------------------------------------------------------------------------| +| 1 | DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] Clause 9.3.1.16 | | +| 2 | 5QI | ELEMENT | FALSE | <i>5QI</i> IE in TS 37.483 [21] Clause 9.3.1.27 or TS 37.483 [21] Clause 9.3.1.28 | | +| 3 | Packet Delay Budget | ELEMENT | FALSE | <i>Packet Delay Budget</i> IE in TS 37.483 [21] Clause 9.3.1.47 | | +| 4 | Packet Error Rate | STRUCTURE | | | <i>Packet Error Rate</i> IE in TS 37.483 [21] Clause 9.3.1.48 | +| 5 | >Scalar factor | ELEMENT | FALSE | <i>Scalar</i> IE in TS 37.483 [21] Clause 9.3.1.48 | | +| 6 | >Exponent factor | ELEMENT | FALSE | <i>Exponent</i> IE in TS 37.483 [21] Clause 9.3.1.48 | | +| 7 | NG-RAN DRB Allocation and Retention Priority | STRUCTURE | | | <i>NG-RAN Allocation and Retention Priority</i> IE in TS 37.483 [21] Clause 9.3.1.29 | +| 8 | >Priority Level | ELEMENT | FALSE | <i>Priority Level</i> IE in TS 37.483 [21] Clause 9.3.1.29 | | +| 9 | >Pre-emption Capability | ELEMENT | FALSE | <i>Pre-emption Capability</i> IE in TS 37.483 [21] Clause 9.3.1.29 | | +| 10 | >Pre-emption Vulnerability | ELEMENT | FALSE | <i>Pre-emption Vulnerability</i> IE in TS 37.483 [21] Clause 9.3.1.29 | | +| 11 | Priority Level of the mapped QoS flows | ELEMENT | FALSE | <i>Priority Level</i> IE in TS 37.483 [21] Clause 9.3.1.51 | | +| 12 | QoS parameters for GBR flows in NG-RAN Bearer | STRUCTURE | | | <i>GBR QoS Flow Information</i> IE in TS 37.483 [21] Clause 9.3.1.30 | +| 13 | >Maximum Flow Bit Rate Downlink | ELEMENT | FALSE | <i>Bit Rate</i> IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 14 | >Guaranteed Flow Bit Rate Downlink | ELEMENT | FALSE | <i>Bit Rate</i> IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 15 | >Maximum Packet Loss Rate Downlink | ELEMENT | FALSE | <i>Packet Loss Rate</i> IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 16 | >Maximum Flow Bit Rate Uplink | ELEMENT | FALSE | <i>Bit Rate</i> IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 17 | >Guaranteed Flow Bit Rate Uplink | ELEMENT | FALSE | <i>Bit Rate</i> IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 18 | >Maximum Packet Loss Rate Uplink | ELEMENT | FALSE | <i>Packet Loss Rate</i> IE in TS 37.483 [21] Clause 9.3.1.30 | | +| 19 | QoS Monitoring Enable Request | ELEMENT | FALSE | <i>QoS Monitoring Request</i> IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 20 | QoS Monitoring Reporting Frequency | ELEMENT | FALSE | <i>QoS Monitoring Reporting Frequency</i> IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 21 | QoS Monitoring Disabled | ELEMENT | FALSE | <i>QoS Monitoring Disabled</i> IE in TS 37.483 [21] Clause 9.3.1.26 | | +| 22 | Reflective QoS Mapping | ELEMENT | FALSE | <i>RDI</i> IE in TS 37.483 [21] Clause 9.3.1.26 | | + +### 8.4.2.2 QoS flow mapping configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to QoS flow mapping Configuration, such as *Bearer Context Management*, *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *DRB ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------|--------------------------|----------|-------------------------------------------------------------------------|----------------------------------------------------------------------| +| 1 | DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] Clause 9.3.1.16 | | +| 2 | List of QoS Flows to be modified in DRB | LIST | | | <i>Flow Mapping Information</i> IE in TS 37.483 [21] Clause 9.3.1.26 | +| 3 | >QoS Flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.12 | +| 4 | >>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] Clause 9.3.1.24 | | +| 5 | >>QoS Flow Mapping Indication | ELEMENT | FALSE | <i>QoS Flow Mapping Indication</i> IE in TS 37.483 [21] Clause 9.3.1.60 | | + +### 8.4.2.3 Logical channel configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to Logical channel Configuration, such as *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related RRC messages. If the *DRB ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +In the case of UE group-based control action, where the relevant entities include more than one DRB subject to LCID configuration, the above procedures are individually invoked for each applicable DRB pertaining to each individual UE of the group. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------------------|--------------------------|----------|--------------------------------------------------------------|------------------------------------------------------------------| +| 1 | DRB ID | ELEMENT | TRUE | <i>DRB-Identity</i> IE in TS 38.331 [22] Clause 6 | | +| 2 | Logical Channel ID | ELEMENT | FALSE | <i>LogicalChannelIdentity</i> IE in TS 38.331 [22] Clause 6 | | +| 3 | List of cell groups to be added | LIST | | | <i>Cell Group To Add</i> IE in TS 37.483 [21] Clause 9.3.3.11 | +| 4 | >Cell group item | STRUCTURE | | | <i>Cell Group Item</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 5 | >>Cell Group ID | ELEMENT | TRUE | <i>Cell Group ID</i> IE in TS 37.483 [21] Clause 9.3.1.11 | | +| 6 | >>UL Configuration | ELEMENT | FALSE | <i>UL Configuration</i> IE in TS 37.483 [21] Clause 9.3.1.33 | | +| 7 | List of cell groups to be modified | LIST | | | <i>Cell Group To Modify</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 8 | >Cell group item | STRUCTURE | | | <i>Cell Group Item</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 9 | >>Cell Group ID | ELEMENT | TRUE | <i>Cell Group ID</i> IE in TS 37.483 [21] Clause 9.3.1.11 | | +| 10 | >>UL Configuration | ELEMENT | FALSE | <i>UL Configuration</i> IE in TS 37.483 [21] Clause 9.3.1.11 | | +| 11 | List of cell groups to be removed | LIST | | | <i>Cell Group To Remove</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 12 | >Cell group item | STRUCTURE | | | <i>Cell Group Item</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 13 | >>Cell Group ID | ELEMENT | FALSE | <i>Cell Group ID</i> IE in TS 37.483 [21] Clause 9.3.1.11 | | +| 14 | Uplink Specific Parameters | STRUCTURE | | | <i>ul-SpecificParameters</i> IE in TS 38.331 [22] Clause 6 | +| 15 | >Priority | ELEMENT | FALSE | <i>priority</i> IE in TS 38.331 [22] Clause 6 | | +| 16 | >Prioritized Bit rate | ELEMENT | FALSE | <i>prioritisedBitRate</i> IE in TS 38.331 [22] Clause 6 | | +| 17 | >Bucket Size Duration | ELEMENT | FALSE | <i>bucketSizeDuration</i> IE in TS 38.331 [22] Clause 6 | | +| 18 | >List of Allowed Serving Cells | LIST | | | <i>allowedServingCells</i> IE in TS 38.331 [22] Clause 6 | +| 19 | >>Allowed Serving Cell Item | STRUCTURE | | | | +| 20 | >>>Serving Cell Index | ELEMENT | FALSE | <i>ServCellIndex</i> IE in TS 38.331 [22] Clause 6 | | +| 21 | >List of Allowed SCS Configuration | LIST | | | <i>allowedSCS-List</i> IE in TS 38.331 [22] Clause 6 | +| 22 | >>Allowed SCS Configuration Item | STRUCTURE | | | | +| 23 | >>Subcarrier Spacing | ELEMENT | FALSE | <i>SubCarrierSpacing</i> IE in TS 38.331 [22] | | + +| | Configuration | | | Clause 6 | | +|----|-------------------------------------------|---------|-------|----------------------------------------------------------------------|--| +| 24 | >Maximum PUSCH Duration | ELEMENT | FALSE | <i>maxPUSCH-Duration</i> IE in TS 38.331 [22] Sec 6 | | +| 25 | >Configured Grant Type 1 Allowed | ELEMENT | FALSE | <i>configuredGrantTypeAllowed</i> IE in TS 38.331 [22] Clause 6 | | +| 26 | >Logical Channel SR – Mask | ELEMENT | FALSE | <i>logicalChannelSR-Mask</i> IE in TS 38.331 [22] Clause 6 | | +| 27 | >Logical Channel SR – Delay Timer Applied | ELEMENT | FALSE | <i>logicalChannelSR-DelayTimerApplied</i> IE in TS 38.331 [22] Sec 6 | | +| 28 | >Bit Rate Query Prohibit Timer | ELEMENT | FALSE | <i>bitRateQueryProhibitTimer</i> IE in TS 38.331 [22] Clause 6 | | +| 29 | >RLC re-establishment | ELEMENT | FALSE | <i>reestablishRLC</i> IE in TS 38.331 [22] | | +| 30 | >Logical Channel Group | ELEMENT | FALSE | <i>logicalChannelGroup</i> IE in TS 38.331 [22] | | + +#### 8.4.2.4 Radio Bearer Admission Control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to Radio Bearer Admission Control, such as *Bearer Context Management*, *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *DRB ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics description | +|------------------|---------------------------------|--------------------------|----------|-------------------------------------------------------------------------------------|----------------------------------------------------------------| +| 1 | DRB Identity | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] Clause 9.3.1.16 | | +| 2 | List of cell groups to be added | LIST | | | <i>Cell Group To Add</i> IE in TS 37.483 [21] Clause 9.3.3.11 | +| 3 | >Cell group item | STRUCTURE | | | <i>Cell Group Item</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 4 | >>Cell Group ID | ELEMENT | TRUE | <i>Cell Group ID</i> IE in TS 37.483 [21] Clause 9.3.1.11 | | +| 5 | SDAP Configuration | STRUCTURE | | | <i>SDAP Configuration</i> IE in TS 37.483 [21] Clause 9.3.1.39 | +| 6 | >PDU Session ID | ELEMENT | FALSE | <i>PDU-SessionID</i> IE in TS 38.331 [22] Sec 6 | | +| 7 | >Default DRB | ELEMENT | FALSE | <i>Default DRB</i> IE in TS 37.483 [21] Clause 9.3.1.39 | | +| 8 | PDCP Configuration | STRUCTURE | | | <i>PDCP Configuration</i> IE in TS 37.483 [21] Clause 9.3.1.38 | +| 9 | >RLC mode | ELEMENT | FALSE | <i>RLC mode</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 10 | >PDCP Duplication | ELEMENT | FALSE | <i>PDCP Duplication</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 11 | >UL Data Split Threshold | ELEMENT | FALSE | <i>UL Data Split Threshold</i> IE in TS 37.483 [21] Clause 9.3.1.43 | | +| 12 | >PDCP Re-establishment | ELEMENT | FALSE | <i>PDCP Re-establishment</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 13 | >PDCP Data Recovery | ELEMENT | FALSE | <i>PDCP Data Recovery</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 14 | >Out-of-Order Delivery | ELEMENT | FALSE | <i>Out of Order Delivery</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 15 | >PDCP Status Report Indication | ELEMENT | FALSE | <i>PDCP Status Report Indication</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 16 | >Number of PDCP duplication | ELEMENT | FALSE | <i>Additional PDCP duplication Information</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 17 | >UL More than one RLC | STRUCTURE | | | <i>moreThanOneRLC</i> IE in TS 38.331 [22] Clause 6 | +| 18 | >>Primary Path | STRUCTURE | | | <i>primaryPath</i> IE in TS 38.331 [22] Clause 6 | +| 19 | >>>Cell Group ID | ELEMENT | TRUE | <i>cellGroup</i> IE in TS 38.331 [22] Clause 6 | | +| 20 | >>>Logical Channel ID | ELEMENT | FALSE | <i>logicalChannel</i> IE in TS 38.331 [22] Sec 6 | | +| 21 | >UL More than two RLC | STRUCTURE | | | <i>moreThanTwoRLC-DRB-r16</i> IE in TS 38.331 [22] Clause 6 | +| 22 | >>Split Secondary Path | ELEMENT | FALSE | <i>splitSecondaryPath</i> IE in TS 38.331 [22] | | + +| | | | | | | +|----|------------------------|-----------|-------|------------------------------------------------------|-------------------------------------------------------------| +| | | | | Sec 6 | | +| 23 | >>Duplication State | ELEMENT | FALSE | <i>duplicationState</i> IE in TS 38.331 [22] Sec 6 | | +| 17 | >DL More than one RLC | STRUCTURE | | | <i>moreThanOneRLC</i> IE in TS 38.331 [22] Clause 6 | +| 18 | >>Primary Path | STRUCTURE | | | <i>primaryPath</i> IE in TS 38.331 [22] Clause 6 | +| 19 | >>>Cell Group ID | ELEMENT | TRUE | <i>cellGroup</i> IE in TS 38.331 [22] Clause 6 | | +| 20 | >>>Logical Channel ID | ELEMENT | FALSE | <i>logicalChannel</i> IE in TS 38.331 [22] Sec 6 | | +| 21 | >DL More than two RLC | STRUCTURE | | | <i>moreThanTwoRLC-DRB-r16</i> IE in TS 38.331 [22] Clause 6 | +| 22 | >>Split Secondary Path | ELEMENT | FALSE | <i>splitSecondaryPath</i> IE in TS 38.331 [22] Sec 6 | | +| 23 | >>Duplication State | ELEMENT | FALSE | <i>duplicationState</i> IE in TS 38.331 [22] Sec 6 | | + +#### 8.4.2.5 DRB Termination Control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to DRB Termination change, such as *Dual Connectivity Secondary Node Modification (MN/SN initiated)*, *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *DRB ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Param | RAN Parameter definition | Semantics Description | +|------------------|------------------------------------------------------|--------------------------|-----------|-------------------------------------------------------------------------|----------------------------------------------------------------------| +| 1 | List of DRBs to be modified to SN-Termination | LIST | | | <i>DRBs To Be Modified</i> IE in TS 38.423 [15] Clause 9.2.1.11 | +| 2 | >DRB Item to be modified to SN-Termination | STRUCTURE | | | <i>DRBs To Be Modified Item</i> IE in TS 38.423 [15] Clause 9.2.1.11 | +| 3 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.423 [15] Clause 9.2.3.33 | | +| 4 | >>Logical Channel ID | ELEMENT | FALSE | <i>LCID</i> IE in TS 38.423 [15] Clause 9.2.3.70 | | +| 5 | >>RLC Status | ELEMENT | FALSE | <i>RLC Status</i> IE in TS 38.423 [15] Clause 9.2.3.80 | | +| 6 | >>List of QoS flows to be modified to SN-Termination | LIST | | | <i>QoS Flows List</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 7 | >>>QoS flow item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 8 | >>>>QoS flow ID | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.1.15 | | +| 9 | >>>>QoS Flow Mapping Indication | ELEMENT | FALSE | <i>QoS Flow Mapping Indication</i> IE in TS 38.423 [15] Clause 9.2.1.15 | | +| 10 | List of DRBs to be modified to MN-Termination | LIST | | | <i>DRBs To Be Modified</i> IE in TS 38.423 [15] Clause 9.2.1.9 | +| 11 | >DRB Item to be modified to MN-Termination | STRUCTURE | | | <i>DRBs To Be Modified Item</i> IE in TS 38.423 [15] Clause 9.2.1.9 | +| 12 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.423 [15] Clause 9.2.3.33 | | +| 13 | >>Logical Channel ID | ELEMENT | FALSE | <i>LCID</i> IE in TS 38.423 [15] Clause 9.2.3.70 | | +| 14 | >>RLC Status | ELEMENT | FALSE | <i>RLC Status</i> IE in TS 38.423 [15] Clause 9.2.3.80 | | +| 15 | >>List of QoS flows to be modified to SN-Termination | LIST | | | <i>QoS Flows List</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 16 | >>>QoS flow item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 17 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 18 | >>>>QoS Flow Mapping Indication | ELEMENT | FALSE | <i>QoS Flow Mapping Indication</i> IE in TS 38.423 [15] Clause 9.2.1.15 | | + +### 8.4.2.6 DRB Split Ratio Control + +Upon receiving the *RIC Control Request* message, in the presence of *Downlink PDCP Data Split* IE, the E2 node shall split the downlink PDCP traffic between the Master Node and Secondary Node over the X2/Xn interface based on the recommended ratio. In the presence of *Uplink PDCP Data Split Threshold* IE, the E2 node shall invoke procedures related to DRB Split Ratio Control, such as *Bearer Context Management*, *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *DRB ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------|--------------------------|----------|---------------------------------------------------------------------|-------------------------------------------------------------------------------| +| 1 | DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] Clause 9.3.1.16 | | +| 2 | Uplink PDCP Data Split Threshold | ELEMENT | FALSE | <i>UL Data Split Threshold</i> IE in TS 37.483 [21] Clause 9.3.1.43 | | +| 3 | Downlink PDCP Data Split | ELEMENT | FALSE | INTEGER (0..100) Defined in Clause 9.4.2 | Indicates the percentage of PDCP traffic that the MN has to split with the SN | + +### 8.4.2.7 PDCP Duplication Control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to PDCP Duplication Control, such as *Bearer Context Management*, *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *DRB ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +In the case of UE group-based control action, where the relevant entities include more than one DRB subject to the PDCP duplication control action, the above procedures are individually invoked for each applicable DRB pertaining to each individual UE of the group. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------|--------------------------|----------|-------------------------------------------------------------------------------------|-------------------------------------------------------------| +| 1 | DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] Clause 9.3.1.16 | | +| 2 | PDCP Duplication | ELEMENT | FALSE | <i>PDCP Duplication</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 3 | UL More Than One RLC | STRUCTURE | | | <i>moreThanOneRLC</i> IE in TS 38.331 [22] | +| 4 | >Primary Path | STRUCTURE | | | <i>primaryPath</i> IE in TS 38.331 [22] Clause 6 | +| 5 | >>Cell Group ID | ELEMENT | TRUE | <i>cellGroup</i> IE in TS 38.331 [22] Clause 6 | | +| 6 | >>Logical Channel ID | ELEMENT | FALSE | <i>logicalChannel</i> IE in TS 38.331 [22] Sec 6 | | +| 7 | UL More Than Two RLC | STRUCTURE | | | <i>moreThanTwoRLC-DRB-r16</i> IE in TS 38.331 [22] Clause 6 | +| 8 | >Split Secondary Path | ELEMENT | FALSE | <i>splitSecondaryPath</i> IE in TS 38.331 [22] Sec 6 | | +| 9 | >Duplication State | ELEMENT | FALSE | <i>duplicationState</i> IE in TS 38.331 [22] Sec 6 | | +| 10 | PDCP Duplication Activation | ELEMENT | FALSE | <i>Duplication Activation</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 11 | Number of PDCP duplication | ELEMENT | FALSE | <i>Additional PDCP duplication Information</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | + +## 8.4.3 Radio Resource Allocation Control + +### 8.4.3.1 DRX Parameter Configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to DRX Parameter Configuration, such as *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------|--------------------------|----------|--------------------------------------------------------------------|-----------------------| +| 1 | Long DRX Cycle Length | ELEMENT | FALSE | <i>Long DRX Cycle Length</i> IE in TS 38.473 [19] Clause 9.3.1.24 | | +| 2 | Short DRX Cycle Length | ELEMENT | FALSE | <i>Short DRX Cycle Length</i> IE in TS 38.473 [19] Clause 9.3.1.24 | | +| 3 | Short DRX Cycle Timer | ELEMENT | FALSE | <i>Short DRX Cycle Timer</i> IE in TS 38.473 [19] Clause 9.3.1.24 | | + +### 8.4.3.2 Scheduling Request Parameter Configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to Scheduling Request Parameter Configuration, such as *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *Scheduling Request ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Param | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------------------|--------------------------|-----------|-------------------------------------------------|------------------------------------------------------------| +| 1 | List of Scheduling Requests for modification | LIST | | | <i>schedulingRequestToAddModList</i> IE in TS 38.331 [22] | +| 2 | >Scheduling Request Item | STRUCTURE | | | <i>SchedulingRequestToAddMod</i> IE in TS 38.331 [22] | +| 3 | >>Scheduling Request ID | ELEMENT | TRUE | <i>SchedulingRequestId</i> IE in TS 38.331 [22] | | +| 4 | >>SR Prohibit Timer | ELEMENT | FALSE | <i>sr-ProhibitTimer</i> IE in TS 38.331 [22] | | +| 5 | >>SR Transmission Max | ELEMENT | FALSE | <i>sr-TransMax</i> IE in TS 38.331 [22] | | +| 6 | List of Scheduling Requests for release | LIST | | | <i>schedulingRequestToReleaseList</i> IE in TS 38.331 [22] | +| 7 | >Scheduling Request Item | STRUCTURE | | | | +| 8 | >>Scheduling Request ID | ELEMENT | TRUE | <i>SchedulingRequestId</i> IE in TS 38.331 [22] | | + +### 8.4.3.3 Semi-Persistent Scheduling Parameter Configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to Scheduling Request Parameter Configuration, such as *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------|--------------------------|----------|-------------------------------------------------------|-----------------------------------------------| +| 1 | SPS-Config | STRUCTURE | | | <i>SPS-Config</i> IE in TS 38.331 [22] Clause | +| 2 | >SPS Periodicity | ELEMENT | FALSE | <i>periodicity</i> IE in TS 38.331 [22] Clause | | +| 3 | >Number of HARQ Processes | ELEMENT | FALSE | <i>nrofHARQ-Processes</i> IE in TS 38.331 [22] Clause | | +| 4 | >MCS Table | ELEMENT | FALSE | <i>mcs-Table</i> IE in TS 38.331 [22] Clause | | + +### 8.4.3.4 Configured Grant Configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to Scheduling Request Parameter Configuration, such as *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------------------|--------------------------|----------|---------------------------------------------------------------|--------------------------------------------------------------| +| 1 | Grant Configuration | STRUCTURE | | | <i>ConfiguredGrantConfig</i> IE in 38.331 Clause | +| 2 | >MCS Table | ELEMENT | FALSE | <i>mcs-Table</i> IE in TS 38.331 [22] Clause | | +| 3 | >MCS Table Without Transform Precoder | ELEMENT | FALSE | <i>Mcs-TableTransformPrecoder</i> IE in TS 38.331 [22] Clause | | +| 4 | >Resource Allocation | ELEMENT | FALSE | <i>resourceAllocation</i> IE in TS 38.331 [22] Clause | | +| 5 | >Number of HARQ processes | ELEMENT | FALSE | <i>nrofHARQ-Processes</i> IE in TS 38.331 [22] Clause | | +| 6 | >HARQ retransmissions | ELEMENT | FALSE | <i>nrofHARQ-Process</i> IE in TS 38.331 [22] Clause | | +| 7 | >Number of repetitions of HARQ PDU | ELEMENT | FALSE | <i>repK</i> IE in TS 38.331 [22] Clause | | +| 8 | >Redundancy Version Format | ELEMENT | FALSE | <i>repK-RV</i> IE in TS 38.331 [22] Clause | | +| 9 | >UL Transmission periodicity | ELEMENT | FALSE | <i>periodicity</i> IE in TS 38.331 [22] Clause | | +| 10 | >Configured grant timer | ELEMENT | FALSE | <i>configuredGrantTimer</i> IE in TS 38.331 [22] Clause | | +| 11 | >RRC Configured Uplink Grant | STRUCTURE | | | <i>rrc-ConfiguredUplinkGrant</i> IE in TS 38.331 [22] Clause | +| 12 | >>Time Domain Offset | ELEMENT | FALSE | <i>timeDomainOffset</i> IE in TS 38.331 [22] Clause | | +| 13 | >>Time Domain Allocation | ELEMENT | FALSE | <i>timeDomainAllocation</i> IE in TS 38.331 [22] Clause | | +| 14 | >>Frequency Domain Allocation | ELEMENT | FALSE | <i>frequencyDomainAllocation</i> IE in TS 38.331 [22] Clause | | +| 15 | >>Antenna Port | ELEMENT | FALSE | <i>antennaPort</i> IE in TS 38.331 [22] Clause | | +| 16 | >>Precoding and number of layers | ELEMENT | FALSE | <i>precodingAndNumberOfLayers</i> IE in TS 38.331 [22] Clause | | +| 17 | >>MCS and TBS | ELEMENT | FALSE | <i>mcsAndTBS</i> IE in TS 38.331 [22] Clause | | +| 18 | >>Path Loss Reference Index | ELEMENT | FALSE | <i>pathlossReferenceIndex</i> IE in TS 38.331 [22] | | + +### 8.4.3.5 CSI Report Configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to CSI Report Configuration, such as *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *CSI Report Config ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Param | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------------------------|--------------------------|-----------|--------------------------------------------------------|---------------------------------------------------------------------------------| +| 1 | List of CSI Report Configurations to Add or Modify | LIST | | | <i>csi-ReportConfigToAddModList</i> IE in TS 38.331 [22] Clause 6 | +| 2 | >CSI Report Configuration Item | STRUCTURE | | | <i>CSI-ReportConfig</i> IE in TS 38.331 [22] Clause 6 | +| 3 | >>CSI Report Config ID | ELEMENT | TRUE | <i>CSI-ReportConfigID</i> IE in TS 38.331 [22] Clause | | +| 4 | >>Carrier | ELEMENT | FALSE | <i>ServCellIndex</i> IE in TS 38.331 [22] Clause | | +| 5 | >>CQI-FormatIndicator | ELEMENT | FALSE | <i>cqi-FormatIndicator</i> IE in TS 38.331 [22] Clause | | +| 6 | >>PMI-FormatIndicator | ELEMENT | FALSE | <i>pmi-FormatIndicator</i> IE in TS 38.331 [22] Clause | | +| 7 | >>CQI Table | ELEMENT | FALSE | <i>cqi-Table</i> IE in TS 38.331 [22] Clause | | +| 8 | >>Sub-band size | ELEMENT | FALSE | <i>subbandSize</i> IE in TS 38.331 [22] Clause | | +| 9 | >>Resources for Channel Measurement | ELEMENT | FALSE | <i>INTEGER</i> | <i>resourcesForChannelMeasurement</i> IE in TS 38.331 [22] Clause 6 | +| 10 | >>CSI-IM Resources for Interference | ELEMENT | FALSE | <i>INTEGER</i> | <i>csi-IM-ResourcesForInterference</i> IE in TS 38.331 [22] Clause 6 | +| 11 | >>NZP-CSI-RS Resources for Interference | ELEMENT | FALSE | <i>INTEGER</i> | <i>nzp-CSI-RS-ResourcesForInterference</i> IE in TS 38.331 [22] Clause 6 | +| 12 | >>Report Config Type | ELEMENT | FALSE | <i>OCTET STRING</i> | <i>reportConfigType</i> IE in TS 38.331 [22] Clause 6 | +| 13 | >>Report Quantity | ELEMENT | FALSE | <i>OCTET STRING</i> | <i>reportQuantity</i> IE in TS 38.331 [22] Clause 6 | +| 14 | >>CSI Reporting Band | ELEMENT | FALSE | <i>OCTET STRING</i> | <i>csi-ReportingBand</i> IE in TS 38.331 [22] Clause 6 | +| 15 | >>Time Restriction for Channel Measurements | ELEMENT | FALSE | <i>INTEGER</i> | <i>timeRestrictionForChannelMeasurements</i> IE in TS 38.331 [22] Clause 6 | +| 16 | >>Time Restriction for Interference Measurements | ELEMENT | FALSE | <i>INTEGER</i> | <i>timeRestrictionForInterferenceMeasurements</i> IE in TS 38.331 [22] Clause 6 | +| 17 | >>Codebook Configuration Item | ELEMENT | FALSE | <i>OCTET STRING</i> | <i>CodebookConfig</i> IE in TS 38.331 [22] Clause 6 | +| 18 | >>Group Based Beam Reporting | ELEMENT | FALSE | <i>OCTET STRING</i> | <i>groupBasedBeamReporting</i> IE in TS 38.331 [22] Clause 6 | +| 19 | List of CSI Report Configurations to Release | LIST | | | <i>csi-ReportConfigToReleaseList</i> IE in TS 38.331 [22] Clause 6 | +| 20 | >CSI Report Configuration Item | STRUCTURE | | | | +| 21 | >>CSI Report Config ID | ELEMENT | TRUE | <i>INTEGER</i> | <i>CSI-ReportConfigId</i> IE in TS 38.331 [22] Clause 6 | + +### 8.4.3.6 Slice-level PRB quota + +Upon receiving the *RIC Control Request* message, the E2 node allocates slice-specific PRB quota for the indicated S-NSSAI in terms of the maximum PRB allocation ratio, minimum PRB allocation ratio and dedicated PRB allocation ratio for the given slice among the available set of PRBs. If the *S-NSSAI* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------------|--------------------------|----------|----------------------------------------------------|----------------------------------------------| +| 1 | RRM Policy Ratio List | LIST | | 0..<maxnoofRRMPolicyRatioGroups> | RRMPolicyRatioList in TS 28.541 | +| 2 | >RRM Policy Ratio Group | STRUCTURE | | | RRMPolicyRatio in TS 28.541 | +| 3 | >>RRM Policy | STRUCTURE | | | RRMPolicy in TS 28.541 | +| 5 | >>RRM Policy Member List | LIST | | 0..<maxnoofRRMPolicyMembers> | RRMPolicyMemberList in TS 28.541 | +| 6 | >>>>RRM Policy Member | STRUCTURE | | | RRMPolicyMember in TS 28.541 | +| 7 | >>>>>PLMN Identity | ELEMENT | FALSE | PLMN Identity IE in TS 38.473 [19] Clause 9.3.1.14 | | +| 8 | >>>>>S-NSSAI | STRUCTURE | | | S-NSSAI IE in TS 38.473 [19] Clause 9.3.1.38 | +| 9 | >>>>>>SST | ELEMENT | FALSE | SST IE in TS 38.473 [19] Clause 9.3.1.38 | | +| 10 | >>>>>>SD | ELEMENT | FALSE | SD IE in TS 38.473 [19] Clause 9.3.1.38 | | +| 11 | >>Min PRB Policy Ratio | ELEMENT | FALSE | INTEGER (0..100) | rRMPolicyMinRatio IE in TS 28.541 | +| 12 | >>Max PRB Policy Ratio | ELEMENT | FALSE | INTEGER (0..100) | rRMPolicyMaxRatio IE in TS 28.541 | +| 13 | >>Dedicated PRB Policy Ratio | ELEMENT | FALSE | INTEGER (0..100) | rRMPolicyDedicatedRatio IE in TS 28.541 | + +| Range bound | Explanation | +|-----------------------------|--------------------------------------------------------------------------------------------------------------| +| maxnoofRRMPolicyRatioGroups | Maximum no. of RAN parameters supported by RAN Function for a specific Control action. The value is <65535>. | +| maxnoofRRMPolicyMembers | Maximum no. of RAN parameters supported by RAN Function for a specific Control action. The value is <65535> | + +### 8.4.3.7 DMRS Resource Configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to DMRS Configuration, such as RRC Message Transfer, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *DMRS-DownlinkConfig* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------|--------------------------|----------|--------------------------|---------------------------| +| 1 | DMRS- | ELEMENT | TRUE | OCTET STRING | DMRS-DownlinkConfig IE in | + +| | | | | | | +|--|----------------|--|--|--|----------------------------| +| | DownlinkConfig | | | | TS 38.331 [22]<br>Clause 6 | +|--|----------------|--|--|--|----------------------------| + +### 8.4.3.8 SRS Configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to SRS Table Configuration, such as *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *SRS Resource ID* or *SRS Resource Set ID* are missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------------------|--------------------------|----------|--------------------------|----------------------------------------------------------------------| +| 1 | List of SRS Resources to Add or Modify | LIST | | | <i>srs-ResourceToAddModList</i> IE in TS 38.331 [22]<br>Clause 6 | +| 2 | >SRS Resource Item | STRUCTURE | | | | +| 3 | >>SRS Resource | ELEMENT | FALSE | OCTET STRING | <i>SRS-Resource</i> IE in TS 38.331 [22]<br>Clause 6 | +| 4 | List of SRS Resources to Release | LIST | | | <i>srs-ResourceToReleaseList</i> IE in TS 38.331 [22]<br>Clause 6 | +| 5 | >SRS Resource Item | STRUCTURE | | | | +| 6 | >>SRS Resource ID | ELEMENT | TRUE | INTEGER | <i>SRS-ResourceId</i> IE in TS 38.331 [22]<br>Clause 6 | +| 7 | List of SRS Resource Sets to Add or Modify | LIST | | | <i>srs-ResourceSetToAddModList</i> IE in TS 38.331 [22]<br>Clause 6 | +| 8 | >SRS Resource Set Item | STRUCTURE | | | | +| 9 | >>SRS Resource Set | ELEMENT | FALSE | OCTET STRING | <i>SRS-ResourceSet</i> IE in TS 38.331 [22]<br>Clause 6 | +| 10 | List of SRS Resource Sets to Release | LIST | | | <i>srs-ResourceSetToReleaseList</i> IE in TS 38.331 [22]<br>Clause 6 | +| 11 | >SRS Resource Set Item | STRUCTURE | | | | +| 12 | >>SRS Resource Set ID | ELEMENT | TRUE | INTEGER | <i>SRS-ResourceSetId</i> IE in TS 38.331 [22] | + +| | | | | | | +|--|--|--|--|--|----------| +| | | | | | Clause 6 | +|--|--|--|--|--|----------| + +### 8.4.3.9 CSI Resource Configuration + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to CSI Resource Table Configuration, such as *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *CSI Resource Configuration ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------------|--------------------------|----------|--------------------------|--------------------------------------------------------------------------| +| 1 | List of CSI Resource Configuration to Add or Modify | LIST | | | <i>csi-ResourceConfigToAddModList</i> IE in TS 38.331 [22] Clause 6 | +| 2 | >CSI Resource Configuration Item | STRUCTURE | | | | +| 3 | >>CSI Resource Config | ELEMENT | FALSE | OCTET STRING | <i>CSI-ResourceConfig</i> IE in TS 38.331 [22] Clause 6 | +| 4 | List of CSI Resource Configurations to Release | LIST | | | <i>csi-ResourceConfigToReleaseList</i> IE in TS 38.331 [22] Clause 6 | +| 5 | >CSI Resource Configuration Item | STRUCTURE | | | | +| 6 | >>CSI Resource Configuration ID | ELEMENT | TRUE | INTEGER | <i>CSI-ResourceConfigId</i> IE in TS 38.331 [22] Clause 6 | +| 7 | NZP CSI-RS Resource Set to Add or Modify | LIST | | | <i>nzp-CSI-RS-ResourceSetToAddModList</i> IE in TS 38.331 [22] Clause 6 | +| 8 | >NZP CSI-RS Resource Set Item | | | | | +| 9 | >>NZP CSI-RS Resource Set | ELEMENT | FALSE | OCTET STRING | <i>NZP-CSI-RS-ResourceSet</i> IE in TS 38.331 [22] Clause 6 | +| 10 | NZP CSI-RS Resource Set to Release | LIST | | | <i>nzp-CSI-RS-ResourceSetToReleaseList</i> IE in TS 38.331 [22] Clause 6 | +| 11 | >NZP CSI-RS Resource Set Item | STRUCTURE | | | | +| 12 | >>NZP CSI-RS Resource Set ID | ELEMENT | | INTEGER | <i>nzp-CSI-RS-ResourceSetId</i> IE | + +| | | | | | | +|----|---------------------------------------|-----------|-------|--------------|--------------------------------------------------------------------------| +| | | | | | in TS 38.331 [22]<br>Clause 6 | +| 13 | NZP CSI-RS Resource to Add or Modify | LIST | | | <i>nzp-CSI-RS-ResourceToAddModList</i> IE in TS 38.331 [22]<br>Clause 6 | +| 14 | >NZP CSI-RS Resource Item | STRUCTURE | | | | +| 15 | >>NZP CSI-RS Resource | ELEMENT | FALSE | OCTET STRING | <i>NZP-CSI-RS-Resource</i> IE in TS 38.331 [22]<br>Clause 6 | +| 16 | TCI States to Add or Modify | LIST | | | <i>tci-StatesToAddModList</i> IE in TS 38.331 [22]<br>Clause 6 | +| 17 | >TCI State Item | STRUCTURE | | | | +| 18 | >>TCI State | ELEMENT | FALSE | OCTET STRING | <i>tci-State</i> IE in TS 38.331 [22]<br>Clause 6 | +| 19 | TCI States to Release | LIST | | | <i>tci-StatesToReleaseList</i> IE in TS 38.331 [22]<br>Clause 6 | +| 20 | >TCI State Item | STRUCTURE | | | | +| 21 | >>TCI State ID | ELEMENT | FALSE | INTEGER | <i>tci-StateId</i> IE in TS 38.331 [22]<br>Clause 6 | +| 22 | NZP CSI-RS Resource to Release | LIST | | | <i>nzp-CSI-RS-ResourceToReleaseList</i> IE in TS 38.331 [22]<br>Clause 6 | +| 23 | >NZP CSI-RS Resource Item | STRUCTURE | | | | +| 24 | >>NZP CSI-RS Resource ID | ELEMENT | TRUE | INTEGER | <i>nzp-CSI-RS-ResourceId</i> IE in TS 38.331 [22]<br>Clause 6 | +| 25 | CSI SSB Resource Set to Add or Modify | LIST | | | <i>csi-SSB-ResourceSetToAddModList</i> IE in TS 38.331 [22]<br>Clause 6 | +| 26 | >CSI SSB Resource Set Item | STRUCTURE | | | | +| 27 | >>CSI SSB Resource | ELEMENT | FALSE | OCTET STRING | <i>csi-SSB-ResourceSet</i> IE in TS 38.331 [22]<br>Clause 6 | +| 28 | CSI SSB Resource Set to Release | LIST | | | <i>csi-SSB-ResourceSetToReleaseList</i> IE in TS 38.331 [22]<br>Clause 6 | + +| | | | | | | +|----|--------------------------------------|-----------|-------|--------------|----------------------------------------------------------------------| +| | | | | | <i>releaseList IE in TS 38.331 [22] Clause 6</i> | +| 29 | >CSI SSB Resource Set Item | STRUCTURE | | | | +| 30 | >>CSI SSB Resource Set ID | ELEMENT | FALSE | INTEGER | <i>csi-SSB-ResourceSetId IE in TS 38.331 [22] Clause 6</i> | +| 31 | CSI-IM Resource Set to Add or Modify | LIST | | | <i>csi-IM-ResourceSetToAddModList IE in TS 38.331 [22] Clause 6</i> | +| 32 | >CSI-IM Resource Set Item | STRUCTURE | | | | +| 33 | >>CSI-IM Resource Set | ELEMENT | FALSE | OCTET STRING | <i>csi-IM-ResourceSet IE in TS 38.331 [22] Clause 6</i> | +| 34 | CSI-IM Resource Set to Release | LIST | | | <i>csi-IM-ResourceSetToReleaseList IE in TS 38.331 [22] Clause 6</i> | +| 35 | >CSI-IM Resource Set Item | STRUCTURE | | | | +| 36 | >>CSI SSB Resource Set ID | ELEMENT | FALSE | INTEGER | <i>csi-IM-ResourceSetId IE in TS 38.331 [22] Clause 6</i> | +| 37 | CSI-IM Resource to Add or Modify | LIST | | | <i>csi-IM-ResourceToAddModList IE in TS 38.331 [22] Clause 6</i> | +| 38 | >CSI-IM Resource Item | STRUCTURE | | | | +| 39 | >>CSI-IM Resource | ELEMENT | FALSE | OCTET STRING | <i>CSI-IM-Resource IE in TS 38.331 [22] Clause 6</i> | +| 40 | CSI-IM Resource to Release | LIST | | | <i>csi-IM-ResourceToReleaseList IE in TS 38.331 [22] Clause 6</i> | +| 41 | >CSI-IM Resource Item | STRUCTURE | | | | +| 42 | >>CSI-IM Resource ID | ELEMENT | FALSE | INTEGER | <i>CSI-IM-ResourceId IE in TS 38.331 [22] Clause 6</i> | + +## 8.4.4 Connected Mode Mobility Control + +### 8.4.4.1 Handover Control + +Upon receiving the *RIC Control Request* message, in the case of Xn/X2 or NG or inter-RAT handovers, the E2 node shall invoke procedures, such as *Handover Preparation* related to UE Mobility Management, *Bearer Context Modification*, *UE Context Modification*, *RRC Message Transfer*, etc. In the case of intra-gNB or F1 handover, the E2 node shall invoke procedures, such as *UE Context Modification*, *RRC Message Transfer*, etc. The E2 node includes the IEs corresponding to one or more of parameters described below in the related interface messages. If the *Target Primary Cell ID* IE is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure* message. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------------|--------------------------|----------|-----------------------------------------------------------------|-----------------------------------------------------------------------------------| +| 1 | Target Primary Cell ID | STRUCTURE | | | <i>Target Cell Global ID IE</i> in TS 38.423 [15] Clause 9.2.3.25 | +| 2 | >CHOICE Target Cell | STRUCTURE | | | <i>Target Cell IE</i> in TS 38.423 [15] Clause 9.2.3.25 | +| 3 | >>NR Cell | STRUCTURE | | | <i>NR IE</i> in TS 38.423 [15] Clause 9.2.3.25 | +| 4 | >>>NR CGI | ELEMENT | FALSE | <i>NR CGI IE</i> in TS 38.423 [15] Clause 9.2.2.7 | | +| 5 | >>E-UTRA Cell | STRUCTURE | | | <i>E-UTRA IE</i> in TS 38.423 [15] Clause 9.2.3.25 | +| 6 | >>>E-UTRA CGI | ELEMENT | FALSE | <i>E-UTRA CGI IE</i> in TS 38.423 [15] Clause 9.2.2.8 | | +| 7 | List of PDU sessions for handover | LIST | | | <i>PDU Session Resources To Be Setup List IE</i> in TS 38.423 [15] Clause 9.2.1.1 | +| 8 | >PDU session Item for handover | STRUCTURE | | | <i>PDU Session Resources To Be Setup Item IE</i> in TS 38.423 [15] Clause 9.2.1.1 | +| 9 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID IE</i> in TS 38.423 [15] Clause 9.2.3.18 | | +| 10 | >>List of QoS flows in the PDU session | LIST | | | <i>QoS Flows To Be Setup List IE</i> in TS 38.423 [15] Clause 9.2.1.1 | +| 11 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow To Be Setup Item IE</i> in TS 38.423 [15] Clause 9.2.1.1 | +| 12 | >>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier IE</i> in TS 38.423 [15] Clause 9.2.3.10 | | +| 13 | List of DRBs for handover | LIST | | | <i>DRB to Be Setup List IE</i> in TS 38.473 [19] Clause 9.2.2.1 | +| 14 | >DRB item for handover | STRUCTURE | | | <i>DRB to Be Setup Item IE</i> in TS 38.473 [19] Clause 9.2.2.1 | +| 15 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID IE</i> in TS 38.473 [19] Clause 9.3.1.8 | | +| 16 | >>List of QoS flows in the DRB | LIST | | | <i>QoS Flows Information To Be Setup IE</i> in TS 37.483 [21] Clause 9.3.3.2 | +| 17 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item IE</i> in TS 37.483 [21] Clause 9.3.1.25 | +| 18 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier IE</i> in TS 37.483 [21] Clause 9.3.1.24 | | +| 19 | List of Secondary cells to be setup | LIST | | | <i>Scell To Be Setup List IE</i> in TS 38.473 [19] Clause 9.2.2.1 | +| 20 | >Secondary cell Item to be setup | STRUCTURE | | | <i>Scell To Be Setup Items IE</i> in TS 38.473 [19] Clause 9.2.2.1 | + +| | | | | | | +|----|---------------------|---------|-------|----------------------------------------------|--| +| 21 | >>Secondary cell ID | ELEMENT | FALSE | Scell ID IE in TS 38.473 [19] Clause 9.2.2.1 | | +|----|---------------------|---------|-------|----------------------------------------------|--| + +## 8.4.4.2 Conditional Handover Control + +Upon receiving the *RIC Control Request* message, in the case of Xn/X2 or NG or inter-RAT conditional handovers, the E2 node shall invoke procedures, such as *Handover Preparation* related to UE Mobility Management, *Bearer Context Modification*, *UE Context Modification*, *RRC Message Transfer*, etc. involving the candidate target cells (note that there is only one *Handover Preparation* in the case of NG or inter-RAT handovers). In the case of intra-gNB or F1 conditional handover, the E2 node shall invoke procedures, such as *UE Context Modification*, *RRC Message Transfer*, etc. The E2 node includes the IEs corresponding to one or more of parameters described below in the related interface messages. If the *Target Cell* IE is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure* message. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Param | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------------------------------------|--------------------------|-----------|-----------------------------------------------------------------|-----------------------------------------------------------------------------------| +| 1 | List of Candidate target primary cells | LIST | | | <i>Candidate SpCell List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 2 | >Candidate target primary cell item | STRUCTURE | | | <i>Candidate SpCell Item IEs</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 3 | >>CHOICE Target Cell | STRUCTURE | | | <i>Target Cell</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 4 | >>>NR | STRUCTURE | | | <i>NR</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 5 | >>>>NR CGI | ELEMENT | FALSE | <i>NR CGI</i> IE in TS 38.423 [15] Clause 9.2.2.7 | | +| 6 | >>>E-UTRA | STRUCTURE | | | <i>E-UTRA</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 7 | >>>>E-UTRA CGI | ELEMENT | FALSE | <i>E-UTRA CGI</i> IE in TS 38.423 [15] Clause 9.2.2.8 | | +| 8 | >>Estimated Arrival Probability | ELEMENT | FALSE | | | +| 9 | List of PDU sessions for handover | LIST | | | <i>PDU Session Resources To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 10 | >PDU session Item for handover | STRUCTURE | | | <i>PDU Session Resources To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 11 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.3.18 | | +| 12 | >>List of QoS flows in the PDU session | LIST | | | <i>QoS Flows To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 13 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 14 | >>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 15 | Candidate target primary cell global ID for NG handover | STRUCTURE | | | <i>Target Cell ID</i> IE in TS 38.413 [11] Clause 9.3.1.73 | +| 16 | >CHOICE <i>Target Cell</i> | STRUCTURE | | | <i>Target Cell</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 17 | >>NR Cell | STRUCTURE | | | <i>NR</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 18 | >>>NR CGI | ELEMENT | FALSE | <i>NR CGI</i> IE in TS 38.423 [15] Clause 9.2.2.7 | | + +| | | | | | | +|----|-------------------------------------|-----------|-------|-----------------------------------------------------------------|-----------------------------------------------------------------------| +| 19 | >>E-UTRA Cell | STRUCTURE | | | <i>E-UTRA</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 20 | >>>E-UTRA CGI | ELEMENT | FALSE | <i>E-UTRA CGI</i> IE in TS 38.423 [15] Clause 9.2.2.8 | | +| 21 | List of DRBs for handover | LIST | | | <i>DRB To Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 22 | >DRB item for handover | STRUCTURE | | | <i>DRB To Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 23 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.473 [19] Clause 9.3.1.8 | | +| 24 | >>List of QoS flows in the DRB | LIST | | | <i>Flows Mapped To DRB Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 25 | >>>QoS flow Item | STRUCTURE | | | | +| 26 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.473 [19] Clause 9.3.1.63 | | +| 27 | List of Secondary cells to be setup | LIST | | | <i>SCell To Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 28 | >Secondary cell Item to be setup | STRUCTURE | | | <i>SCell To Be Setup Item IEs</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 29 | >>Secondary cell ID | ELEMENT | FALSE | <i>SCell ID</i> IE in TS 38.473 [19] Clause 9.2.2.1 | | + +### 8.4.4.3 DAPS Handover Control + +Upon receiving the *RIC Control Request* message, in the case of Xn/X2 DAPS handovers, the E2 node shall invoke procedures, such as *Handover Preparation* related to UE Mobility Management, *Bearer Context Modification*, *UE Context Modification*, *RRC Message Transfer*, etc. In the case of intra-gNB or F1 DAPS handover, the E2 node shall invoke procedures, such as *UE Context Modification*, *RRC Message Transfer*, etc. The E2 node includes the IEs corresponding to one or more of parameters described below in the related interface messages. If the *Target Primary Cell ID* IE is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure* message. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Param | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------|--------------------------|-----------|-----------------------------------------------------------------|---------------------------------------------------------------------------------| +| 1 | Target Primary Cell ID | STRUCTURE | | | <i>Target Cell Global ID</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 2 | >CHOICE <i>Target Cell</i> | STRUCTURE | | | <i>Target Cell</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 3 | >>NR Cell | STRUCTURE | | | <i>NR</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 4 | >>>NR CGI | ELEMENT | FALSE | <i>NR CGI</i> IE in TS 38.423 [15] Clause 9.2.2.7 | | +| 5 | >>E-UTRA Cell | STRUCTURE | | | <i>E-UTRA</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 6 | >>>E-UTRA CGI | ELEMENT | FALSE | <i>E-UTRA CGI</i> IE in TS 38.423 [15] Clause 9.2.2.8 | | +| 7 | List of DRBs subject to DAPS handover | LIST | | | <i>Source DRB to QoS Flow Mapping List</i> IE in TS 38.423 [15] Clause 9.2.1.17 | +| 8 | >DRB item for handover | STRUCTURE | | | <i>DRB to QoS Flow Mapping Item</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 9 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.423 [15] Clause 9.2.3.33 | | +| 10 | >>List of QoS flows in the DRB | LIST | | | <i>QoS Flows List</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 11 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 12 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 13 | >>>>QoS flow mapping indication | ELEMENT | FALSE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.79 | | +| 14 | List of DRBs subject to handover without DAPS | LIST | | | <i>Source DRB to QoS Flow Mapping List</i> IE in TS 38.423 [15] Clause 9.2.1.17 | +| 15 | >DRB item for handover | STRUCTURE | | | <i>DRB to QoS Flow Mapping Item</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 16 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.423 [15] Clause 9.2.3.33 | | +| 17 | >>List of QoS flows in the DRB | LIST | | | <i>QoS Flows List</i> IE in TS 38.423 [15] Clause | + +| | | | | | | +|----|-------------------------------------------------|-----------|-------|-----------------------------------------------------------------|-----------------------------------------------------------------------------------| +| | | | | | 9.2.1.15 | +| 18 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 19 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 20 | >>>>QoS flow mapping indication | ELEMENT | FALSE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.79 | | +| 21 | List of PDU Sessions subject for handover | LIST | | | <i>PDU Session Resources To Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 22 | >PDU Session Item | STRUCTURE | | | <i>PDU Session Resources To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 23 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.1.1 | | +| 24 | >>List of DRBs subject to DAPS handover | LIST | | | <i>Source DRB to QoS Flow Mapping List</i> IE in TS 38.423 [15] Clause 9.2.1.17 | +| 25 | >>>DRB item for handover | STRUCTURE | | | <i>DRB to QoS Flow Mapping Item</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 26 | >>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.423 [15] Clause 9.2.3.33 | | +| 27 | >>>>List of QoS flows in the DRB | LIST | | | <i>QoS Flows List</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 28 | >>>>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 29 | >>>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 30 | >>>>>QoS flow mapping indication | ELEMENT | FALSE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.79 | | +| 31 | >>List of DRBs subject to handover without DAPS | LIST | | | <i>Source DRB to QoS Flow Mapping List</i> IE in TS 38.423 [15] Clause 9.2.1.17 | +| 32 | >>>DRB item for handover | STRUCTURE | | | <i>DRB to QoS Flow Mapping Item</i> IE in TS 38.423 [15] Clause 9.2.1.15 | + +| | | | | | | +|----|-----------------------------------|-----------|-------|-----------------------------------------------------------------|------------------------------------------------------------| +| 33 | >>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.423 [15] Clause 9.2.3.33 | | +| 34 | >>>>List of QoS flows in the DRB | LIST | | | <i>QoS Flows List</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 35 | >>>>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 38.423 [15] Clause 9.2.1.15 | +| 36 | >>>>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 37 | >>>>>>QoS flow mapping Indication | ELEMENT | FALSE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.79 | | + +## 8.4.5 Radio Access Control + +### 8.4.5.1 UE admission control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to UE admission control, such as *PDU Session Management*, *Bearer Context Management*, *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------------------|--------------------------|----------|-------------------------------------------------------------------------|-----------------------------------------------------------------------------------| +| 1 | Primary Cell ID | STRUCTURE | | | <i>Target Cell Global ID</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 2 | >CHOICE <i>Primary Cell</i> | STRUCTURE | | | <i>Target Cell</i> IE in TS 38.423 [15] clause 9.2.3.25 | +| 3 | >>NR Cell | STRUCTURE | | | <i>NR</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 4 | >>>NR CGI | ELEMENT | FALSE | <i>NR CGI</i> IE in TS 38.423 [15] Clause 9.2.2.7 | | +| 5 | >>E-UTRA Cell | STRUCTURE | | | <i>E-UTRA</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 6 | >>>E-UTRA CGI | ELEMENT | FALSE | <i>E-UTRA CGI</i> IE in TS 38.423 [15] Clause 9.2.2.8 | | +| 7 | List of PDU sessions for admission | LIST | | | <i>PDU Session Resources To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 8 | >PDU session Item for admission | STRUCTURE | | | <i>PDU Session Resources To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 9 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.3.18 | | +| 10 | >>List of DRBs for admission | LIST | | | <i>DRB to Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 11 | >>>DRB item for admission | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 12 | >>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.473 [19] Clause 9.3.1.8 | | +| 13 | >>>>List of QoS flows in the DRB | LIST | | | <i>QoS Flows Information To Be Setup</i> IE in TS 37.483 [21] Clause 9.3.3.2 | +| 14 | >>>>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.25 | +| 15 | >>>>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] Clause 9.3.1.24 | | +| 16 | >>>>>>QoS flow mapping indication | ELEMENT | TRUE | <i>QoS Flow Mapping Indication</i> IE in TS 37.483 [21] Clause 9.3.1.60 | | +| 17 | >>>List of cell groups to be added | LIST | | | <i>Cell Group To Add</i> IE in TS 37.483 [21] Clause 9.3.3.11 | +| 18 | >>>>Cell group item | STRUCTURE | | | <i>Cell Group Item</i> IE in TS 37.483 [21] Clause 9.3.1.11 | +| 19 | >>>>>Cell Group ID | ELEMENT | TRUE | <i>Cell Group ID</i> IE in TS 37.483 [21] Clause 9.3.1.11 | | +| 20 | >>>SDAP Configuration | STRUCTURE | | | <i>SDAP Configuration</i> IE in TS 37.483 [21] Clause 9.3.1.39 | +| 21 | >>>Default DRB | ELEMENT | FALSE | <i>Default DRB</i> IE in | | + +| | | | | | | +|----|----------------------------------|-----------|-------|-------------------------------------------------------------------------------------|----------------------------------------------------------------| +| | | | | TS 37.483 [21]<br>Clause 9.3.1.39 | | +| 22 | >>>PDCP Configuration | STRUCTURE | | | <i>PDCP Configuration</i> IE in TS 37.483 [21] Clause 9.3.1.38 | +| 23 | >>>RLC mode | ELEMENT | FALSE | <i>RLC mode</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 24 | >>>PDCP Duplication | ELEMENT | FALSE | <i>PDCP Duplication</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 25 | >>>UL Data Split Threshold | ELEMENT | FALSE | <i>UL Data Split Threshold</i> IE in TS 37.483 [21] Clause 9.3.1.43 | | +| 26 | >>>PDCP Re-establishment | ELEMENT | FALSE | <i>PDCP Re-establishment</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 27 | >>>PDCP Data Recovery | ELEMENT | FALSE | <i>PDCP Data Recovery</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 28 | >>>Out-of-Order Delivery | ELEMENT | FALSE | <i>Out of Order Delivery</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 29 | >>>PDCP Status Report Indication | ELEMENT | FALSE | <i>PDCP Status Report Indication</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 30 | >>>Number of PDCP duplication | ELEMENT | FALSE | <i>Additional PDCP duplication Information</i> IE in TS 37.483 [21] Clause 9.3.1.38 | | +| 31 | >>>UL More than one RLC | STRUCTURE | | | <i>moreThanOneRLC</i> IE in TS 38.331 [22] Clause 6 | +| 32 | >>>>Primary Path | STRUCTURE | | | <i>primaryPath</i> IE in TS 38.331 [22] Clause 6 | +| 33 | >>>>>Cell Group ID | ELEMENT | TRUE | <i>cellGroup</i> IE in TS 38.331 [22] Clause 6 | | +| 34 | >>>>>Logical Channel ID | ELEMENT | FALSE | <i>logicalChannel</i> IE in TS 38.331 [22] Sec 6 | | +| 35 | >>>UL More than two RLC | STRUCTURE | | | <i>moreThanTwoRLC-DRB-r16</i> IE in TS 38.331 [22] Clause 6 | +| 36 | >>>>Split Secondary Path | ELEMENT | FALSE | <i>splitSecondaryPath</i> IE in TS 38.331 [22] Sec 6 | | +| 37 | >>>>Duplication State | ELEMENT | FALSE | <i>duplicationState</i> IE in TS 38.331 [22] Sec 6 | | +| 38 | >>>DL More than one RLC | STRUCTURE | | | <i>moreThanOneRLC</i> IE in TS 38.331 [22] Clause 6 | +| 39 | >>>>Primary Path | STRUCTURE | | | <i>primaryPath</i> IE in TS 38.331 [22] Clause 6 | +| 49 | >>>>>Cell Group ID | ELEMENT | TRUE | <i>cellGroup</i> IE in TS 38.331 [22] Clause 6 | | +| 50 | >>>>>Logical Channel ID | ELEMENT | FALSE | <i>logicalChannel</i> IE in TS 38.331 [22] Sec 6 | | + +| | | | | | | +|----|-------------------------------------|-----------|-------|------------------------------------------------------|--------------------------------------------------------------------| +| 51 | >>>DL More than two RLC | STRUCTURE | | | <i>moreThanTwoRLC-DRB-r16</i> IE in TS 38.331 [22] Clause 6 | +| 52 | >>>>Split Secondary Path | ELEMENT | FALSE | <i>splitSecondaryPath</i> IE in TS 38.331 [22] Sec 6 | | +| 53 | >>>>Duplication State | ELEMENT | FALSE | <i>duplicationState</i> IE in TS 38.331 [22] Sec 6 | | +| 54 | List of Secondary cells to be setup | LIST | | | <i>Scell To Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 55 | >Secondary cell Item to be setup | STRUCTURE | | | <i>Scell To Be Setup Items</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 56 | >>Secondary cell ID | ELEMENT | FALSE | <i>Scell ID</i> IE in TS 38.473 [19] Clause 9.2.2.1 | | + +#### 8.4.5.2 RACH backoff control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to RACH backoff control, such as *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------------|--------------------------|----------|-------------------------------------------------------------------|-----------------------------------------------------------| +| 1 | Common RACH Config Parameters | STRUCTURE | | | <i>RACH-ConfigGeneric</i> IE in TS 38.331 [22] Clause 6 | +| 2 | >PRACH Configuration Index | ELEMENT | FALSE | <i>prach-ConfigurationIndex</i> IE in TS 38.331 [22] Sec 6 | | +| 3 | >Zero correlation Zone Config | ELEMENT | FALSE | <i>zeroCorrelationZoneConfig</i> IE in TS 38.331 [22] Sec 6 | | +| 4 | >Preamble Received Target Power | ELEMENT | FALSE | <i>preambleReceivedTargetPower</i> IE in TS 38.331 [22] Clause 6 | | +| 5 | >Preamble Transmission Max | ELEMENT | FALSE | <i>preambleTransMax</i> IE in TS 38.331 [22] Sec 6 | | +| 6 | >Power Ramping Step High Priority | ELEMENT | FALSE | <i>powerRampingStep</i> IE in TS 38.331 [22] Sec 6 | | +| 7 | >Random Access Response Window | ELEMENT | FALSE | <i>ra-ResponseWindow</i> IE in TS 38.331 [22] Sec 6 | | +| 8 | Dedicated RACH Config Parameters | STRUCTURE | | | <i>RACH-ConfigDedicated</i> IE in TS 38.331 [22] Clause 6 | +| 9 | >Random Access Prioritization | STRUCTURE | | | <i>RA-Prioritization</i> IE in TS 38.331 [22] Sec 6 | +| 10 | >>Scaling Factor for Backoff Indicator | ELEMENT | FALSE | <i>scalingFactorBI</i> IE in TS 38.331 [22] Sec 6 | | +| 11 | >>Power Ramping Step High Priority | ELEMENT | FALSE | <i>powerRampingStepHighPriority</i> IE in TS 38.331 [22] Clause 6 | | + +### 8.4.5.3 Access barring control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to Access barring control, such as *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Param | RAN Parameter Definition | Semantics Description | +|------------------|-------------------------------------|--------------------------|-----------|--------------------------------------------------------------|----------------------------------------------------------------| +| 1 | Unified Access Control Barring Info | STRUCTURE | | | <i>uac-BarringInfo</i> IE in TS 38.331 [22] Sec 6 | +| 2 | >UAC Barring for Common List | LIST | | | <i>uac-BarringForCommon</i> IE in TS 38.331 [22] Sec 6 | +| 3 | >>Barring Per Cat | STRUCTURE | | | <i>UAC-BarringPerCat</i> IE in TS 38.331 [22] Clause 6 | +| 4 | >>>Access Category | ELEMENT | FALSE | <i>accessCategory</i> IE in TS 38.331 [22] Sec 6 | | +| 5 | >>>Barring Info Set Index | ELEMENT | FALSE | <i>UAC-BarringInfoSetIndex</i> IE in TS 38.331 [22] Clause 6 | | +| 6 | >UAC Barring for PLMN List | LIST | | | <i>uac-BarringPerPLMN-List</i> IE in TS 38.331 [22] Clause 6 | +| 7 | >>UAC-BarringPerPLMN | STRUCTURE | | | <i>UAC-BarringPerPLMN</i> IE in TS 38.331 [22] Sec 6 | +| 8 | >>>PLMN Identity | ELEMENT | TRUE | 9.3.59 | | +| 9 | >>>CHOICE UAC AC Barring List Type | STRUCTURE | | | <i>Uac-ACBarringListType</i> IE in TS 38.331 [22] Sec 6 | +| 10 | >>>>UAC Implicit AC Barring List | LIST | | | <i>uac-ImplicitACBarringList</i> IE in TS 38.331 [22] Clause 6 | +| 11 | >>>>>UAC Implicit AC Barring Item | STRUCTURE | | | | +| 12 | >>>>>UAC Barring Info Set Index | ELEMENT | FALSE | <i>UAC-BarringInfoSetIndex</i> IE in TS 38.331 [22] Sec 6 | | +| 13 | >>>>UAC Explicit AC Barring List | LIST | | | <i>uac-ExplicitACBarringList</i> IE in TS 38.331 [22] Clause 6 | +| 14 | >>>>>Barring Per Cat | STRUCTURE | | | <i>UAC-BarringPerCat</i> IE in TS 38.331 [22] Clause 6 | +| 15 | >>>>>Access Category | ELEMENT | FALSE | <i>accessCategory</i> IE in TS 38.331 [22] Sec 6 | | +| 16 | >>>>>Barring Info Set Index | ELEMENT | FALSE | <i>UAC-BarringInfoSetIndex</i> IE in TS 38.331 [22] Clause 6 | | +| 17 | >UAC Barring Info Set List | LIST | | | <i>UAC-BarringInfoSetList</i> IE in TS 38.331 [22] Sec 6 | +| 18 | >>UAC Barring Info Set Item | STRUCTURE | | | <i>UAC-BarringInfoSet</i> IE in TS 38.331 [22] Clause 6 | +| 19 | >>>UAC Barring Factor | ELEMENT | FALSE | <i>uac-BarringFactor</i> IE in TS 38.331 [22] Sec 6 | | +| 20 | >>>UAC Barring Time | ELEMENT | FALSE | <i>uac-BarringTime</i> IE in TS 38.331 [22] Sec 6 | | +| 21 | >>>UAC Barring For Access Identity | ELEMENT | FALSE | <i>uac-BarringForAccessIdentity</i> in TS | | + +| | | | | | | +|----|-----------------------------------------------------------------|-----------|-------|---------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | 38.331 [22]<br>Clause 6 | | +| 22 | >CHOICE Access<br>Category 1 – Selection<br>Assistance Info | STRUCTURE | | | <i>uac-AccessCategory1-<br/>SelectionAssistanceInfo</i> IE in TS<br>38.331 [22] Sec 6 | +| 23 | >>PLMN Common | ELEMENT | FALSE | <i>UAC-<br/>AccessCategory<br/>1-<br/>SelectAssistance<br/>Info</i> IE in TS<br>38.331 [22]<br>Clause 6 | | +| 24 | >>Individual PLMN<br>List | LIST | | | <i>individualPLMNList</i> IE in TS<br>38.331 [22] Clause 6 | +| 25 | >>>PLMN Item | STRUCTURE | | | | +| 26 | >>>>UAC<br>Access<br>Category 1<br>Selection<br>Assistance Info | ELEMENT | FALSE | <i>UAC-<br/>AccessCategory<br/>1-<br/>SelectAssistance<br/>Info</i> IE in TS<br>38.331 [22]<br>Clause 6 | | +| 27 | Cell Access<br>Control Barring<br>Info | STRUCTURE | | | | +| 28 | > List of Control<br>plmn-Identity | LIST | | | | +| 29 | >> plmn-<br>Identity | ELEMENT | | 9.3.59 | | +| 30 | >>List of<br>Control cells | LIST | | | | +| 31 | >>>CHOICE<br>Cell Type | STRUCTURE | | | | +| 32 | >>>>NR Cell | STRUCTURE | | 8.1.1.1 | NR IE in TS 38.423 [15] Clause<br>9.2.3.25 | +| 33 | >>>>>NR<br>CGI | ELEMENT | | <i>NR CGI IE in<br/>TS 38.423 [15]<br/>Clause 9.2.2.7</i> | Cell Corresponding to same<br>PLMN | +| 34 | >>>>E-<br>UTRA Cell | STRUCTURE | | 8.1.1.2 | E-UTRA IE in TS 38.423 [15]<br>Clause 9.2.3.25 | +| 35 | >>>>>EUTAN<br>CGI | ELEMENT | | <i>E-UTRA CGI IE<br/>in TS 38.423<br/>[15] Clause<br/>9.2.2.8</i> | | +| 36 | >>><br>cellBarred | ELEMENT | | | Indicated in the MIB message,<br>applicable to all PLMNs when<br>multiple PLMNs are in SIB1.<br>When set to 'barred', the cell is<br>barred for all UEs including<br>emergency calls. Please refer to<br>TS 38.331 [22]. | +| 37 | >>><br>intraFreqResel<br>ection | ELEMENT | | | Indicated in MIB message. It<br>controls cell<br>selection/reselection to intra-<br>frequency cells when the<br>highest-ranked cell is barred or<br>treated as barred by the UE. In<br>the case of multiple PLMNs<br>indicated in SIB1, this field is<br>common for all PLMNs. Please<br>refer to TS 38.331 [22]. | +| 38 | >><br>cellReservedFo<br>rOperatorUse | ELEMENT | | | Indicated in SIB1 message, per-<br>PLMN configuration. When set<br>to 'reserved', the cell is treated<br>as a candidate by the UE with | + +| | | | | | | +|----|-------------------------------|--|--|--|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | | access identity (i.e.) 11 and 15 operating in their HPLMN/EHPLMN. UEs assigned to an Access Identity 0, 1, 2 and 12 to 14 shall behave as if the cell status is "barred" for the registered PLMN or the selected PLMN. Please refer to TS 38.331 [22]. | +| 39 | >><br>cellReservedForOtherUse | | | | Indicated in SIB1 message, applicable to all PLMNs indicated in SIB1. Please refer to TS 38.331 [22]. | + +#### 8.4.5.4 RRC Connection Release Control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to RRC Connection Release control, such as *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------|--------------------------|----------|--------------------------------------------------------|---------------------------------------------------------| +| 1 | CHOICE Redirected Carrier Info | STRUCTURE | | | <i>redirectedCarrierInfo</i> IE in TS 36.331 [23] | +| 2 | >E-UTRA | STRUCTURE | | <i>eutra</i> IE in TS 36.331 [23] | | +| 3 | >>EARFCN | ELEMENT | FALSE | <i>ARFCN-ValueEUTRA</i> IE in TS 36.331 [23] | | +| 4 | >NR | STRUCTURE | | <i>nr-r15</i> IE in TS 36.331 [23] | | +| 5 | >>Carrier Info NR | STRUCTURE | | | <i>CarrierInfoNR-r15</i> IE in TS 36.331 [23] | +| 6 | >>>Carrier Frequency | ELEMENT | FALSE | <i>ARFCN-ValueNR-r15</i> IE in TS 36.331 [23] | | +| 7 | >>>Subcarrier Spacing SSB | ELEMENT | FALSE | <i>subcarrierSpacingSSB-r15</i> IE in TS 36.331 [23] | | +| 8 | Idle Mode Mobility Control Info | STRUCTURE | | | <i>IdleModeMobilityControlInfo</i> IE in TS 36.331 [23] | +| 9 | >Frequency Priority List E-UTRA | LIST | | | <i>FreqPriorityListEUTRA</i> IE in TS 36.331 [23] | +| 10 | >>Frequency Priority Item E-UTRA | STRUCTURE | | | <i>FreqPriorityEUTRA</i> IE in TS 36.331 [23] | +| 11 | >>>Carrier Frequency | ELEMENT | FALSE | <i>carrierFreq</i> IE in TS 38.331 [22] | | +| 12 | >>>Cell Reselection Priority | ELEMENT | FALSE | <i>cellReselectionPriority</i> IE in TS 38.331 [22] | | +| 13 | >>>Cell Reselection Sub Priority | ELEMENT | FALSE | <i>cellReselectionSubPriority</i> IE in TS 38.331 [22] | | +| 14 | >Frequency Priority List NR | LIST | | | <i>FreqPriorityListNR</i> IE in TS 38.331 [22] | +| 15 | >>Frequency Priority Item NR | STRUCTURE | | | <i>FreqPriorityNR</i> IE in TS 38.331 [22] | +| 16 | >>>Carrier Frequency | ELEMENT | FALSE | <i>carrierFreq</i> IE in TS 38.331 [22] | | +| 17 | >>>Cell Reselection Priority | ELEMENT | FALSE | <i>cellReselectionPriority</i> IE in TS 38.331 [22] | | +| 18 | >>>Cell Reselection Sub Priority | ELEMENT | FALSE | <i>cellReselectionSubPriority</i> IE in TS 38.331 [22] | | +| 19 | >T-320 timer expiry | ELEMENT | FALSE | <i>t320</i> IE in TS 38.331 [22] | | + +### 8.4.5.5 RRC Connection Reject Control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to RRC Connection Reject, such as *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------------|--------------------------|----------|-------------------------------------------------------|-----------------------------------------------------| +| 1 | Wait Time | ELEMENT | FALSE | <i>waitTime</i> IE in TS 36.331 [23] | | +| 2 | Deprioritization Requirement | STRUCTURE | | | <i>deprioritisationReq-r11</i> IE in TS 36.331 [23] | +| 3 | >Deprioritization Type | ELEMENT | FALSE | <i>deprioritisationType-r11</i> IE in TS 36.331 [23] | | +| 4 | >Deprioritization Timer | ELEMENT | FALSE | <i>deprioritisationTimer-r11</i> IE in TS 36.331 [23] | | +| 5 | RRC Suspend Indication | ELEMENT | FALSE | <i>rrc-SuspendIndication-r13</i> IE in TS 36.331 [23] | | + +## 8.4.6 Dual Connectivity Control + +### 8.4.6.1 DC Secondary Node Addition Control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to DC Secondary Node Addition Control, such as *Dual Connectivity Secondary Node Addition*, *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. If the *Secondary Node ID* is missing in the *RIC Control Request* message, the E2 node will send a *RIC Control Failure*. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------------------------------|--------------------------|----------|-----------------------------------------------------------------|--------------------------------------------------------------------------------------------| +| 1 | Secondary Node ID | STRUCTURE | | | <i>Global NG-RAN Node ID IE in TS 38.423 [15] Clause 9.2.2.3</i> | +| 2 | >CHOICE Secondary Node Type | STRUCTURE | | | | +| 3 | >>Secondary Node gNB | STRUCTURE | | | <i>Global ng-eNB ID IE in TS 38.423 [15] Clause 9.2.2.1</i> | +| 4 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity IE in TS 38.423 [15] Clause 9.2.2.4</i> | | +| 5 | >>>gNB ID | ELEMENT | FALSE | <i>gNB ID IE in TS 38.423 [15] Clause 9.2.2.1</i> | | +| 6 | >>Secondary Node ng-eNB | STRUCTURE | | | <i>Global ng-eNB ID IE in TS 38.423 [15] Clause 9.2.2.2</i> | +| 7 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity IE in TS 38.423 [15] Clause 9.2.2.4</i> | | +| 8 | >>>ng-eNB ID | ELEMENT | FALSE | <i>Long Macro ng-eNB ID IE in TS 38.423 [15] Clause 9.2.2.2</i> | | +| 9 | >>Secondary Node en-gNB | STRUCTURE | | | <i>en-gNB IE in TS 36.423 [17] Sec</i> | +| 10 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity IE in TS 36.423 [17] Clause 9.2.4</i> | | +| 11 | >>>en-gNB ID | ELEMENT | FALSE | <i>Global en-gNB ID IE in TS 36.423 [17] Clause 9.2.4</i> | | +| 12 | List of PDU Sessions to be Added | LIST | | | <i>PDU Session Resources To Be Added List IE in TS 38.423 [15] Clause 9.1.2.1</i> | +| 13 | >PDU Session to be Added Item | STRUCTURE | | | <i>PDU Session Resources To Be Added Item IE in TS 38.423 [15] Clause 9.1.2.1</i> | +| 14 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID IE in TS 38.423 [15] Clause 9.2.3.18</i> | | +| 15 | >>PDU Session Resource Setup Info – SN-Terminated | STRUCTURE | | | <i>PDU Session Resource Setup Info – SN Terminated IE in TS 38.423 [15] Clause 9.2.1.5</i> | +| 16 | >>>QoS Flow To Be Setup List | LIST | | | <i>QoS Flows To Be Setup List IE in TS 38.423 [15] Clause 9.2.1.5</i> | +| 17 | >>>>QoS Flow Item | STRUCTURE | | | <i>QoS Flows To Be Setup Item IE in TS 38.423 [15] Clause 9.2.1.5</i> | +| 18 | >>>>>QoS Flow | ELEMENT | TRUE | <i>QoS Flow Identifier IE in TS</i> | | + +| | | | | | | +|----|-------------------------------------------------------------|-----------|-------|------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------| +| | Identifier | | | 38.423 [15]<br>Clause 9.2.3.10 | | +| 19 | >>>>QoS<br>Flow<br>Mapping<br>Indication | ELEMENT | FALSE | QoS Flow<br>Mapping<br>Indication IE in<br>TS 38.423 [15]<br>Clause 9.2.3.79 | | +| 20 | >>>Default DRB<br>allowed | ELEMENT | FALSE | Default DRB<br>Allowed IE in TS<br>38.423 [15]<br>Clause 9.2.3.93 | | +| 21 | >>PDU Session<br>Resource Setup Info –<br>MN-Terminated | STRUCTURE | | | PDU Session<br>Resource Setup<br>Info – SN<br>Terminated IE in<br>TS 38.423 [15]<br>Clause 9.2.1.7 | +| 22 | >>>DRBs To Be<br>Setup List | STRUCTURE | | | DRBs To Be<br>Setup List IE in TS<br>38.423 [15]<br>Clause 9.2.1.7 | +| 23 | >>>>DRB To Be<br>Setup Item | STRUCTURE | | | DRBs To Be<br>Setup Item IE in<br>TS 38.423 [15]<br>Clause 9.2.1.7 | +| 24 | >>>>>DRB<br>ID | ELEMENT | TRUE | DRB ID IE in TS<br>37.483 [21]<br>Clause 9.3.1.16 | | +| 25 | >>>>>QoS<br>Flow To Be<br>Setup List | LIST | | | QoS Flows To Be<br>Setup List IE in TS<br>38.423 [15]<br>Clause 9.2.1.5 | +| 26 | >>>>>Q<br>oS Flow<br>Item | STRUCTURE | | | QoS Flow Item IE<br>in TS 38.423 [15]<br>Clause 9.2.3.10 | +| 27 | >>>><br>>>>Q<br>oS<br>Flow<br>Identif<br>ier | ELEMENT | TRUE | QoS Flow<br>Identifier IE in TS<br>38.423 [15]<br>Clause 9.2.3.10 | | +| 28 | >>>><br>>>>Q<br>oS<br>Flow<br>Mappi<br>ng<br>Indica<br>tion | ELEMENT | FALSE | QoS Flow<br>Mapping<br>Indication IE in<br>TS 38.423 [15]<br>Clause 9.2.3.79 | | +| 29 | List of SN-terminated DRB<br>IDs | LIST | | | Additional DRB<br>IDs IE in TS<br>38.423 [15]<br>Clause 9.2.1.29 | +| 30 | >SN-Terminated DRB Item | STRUCTURE | | | | +| 31 | >>DRB Identity | ELEMENT | TRUE | DRB ID IE in TS<br>38.473 [19]<br>Clause 9.3.1.8 | | +| 32 | List of E-RABs to be Added | LIST | | | E-RABs To Be<br>Added List IE in<br>TS 36.423 [17]<br>Clause 9.1.4.1 | +| 33 | >E-RAB to be Added Item | STRUCTURE | | | E-RABs To Be<br>Added Item IE in<br>TS 36.423 [17]<br>Clause 9.1.4.1 | + +| | | | | | | +|----|--------------------------------|-----------|-------|----------------------------------------------------------|-------------------------------------------------------------------------| +| 34 | >>E-RAB ID | ELEMENT | TRUE | <i>E-RAB ID</i> IE in TS 36.423 [17] Clause 9.2.23 | | +| 35 | >>EN-DC Resource Configuration | STRUCTURE | | | <i>EN-DC Resource Configuration</i> IE in TS 36.423 [17] Clause 9.2.108 | +| 36 | >>>PDCP at SgNB | ELEMENT | FALSE | <i>PDCP at SgNB</i> IE in TS 36.423 [17] Clause 9.2.108 | | +| 37 | >>>MCG Resources | ELEMENT | FALSE | <i>MCG resources</i> IE in TS 36.423 [17] Clause 9.2.108 | | +| 38 | >>>SCG Resources | ELEMENT | FALSE | <i>SCG resources</i> IE in TS 36.423 [17] Clause 9.2.108 | | + +### 8.4.6.2 DC Secondary Node Modification Control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to DC Secondary Node Modification Control, such as *Dual Connectivity Secondary Node Modification*, *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------------------------------|--------------------------|----------|-----------------------------------------------------------------|---------------------------------------------------------------------------------------------------| +| 1 | Secondary Node | STRUCTURE | | | <i>Global NG-RAN Node ID IE</i> in TS 38.423 [15] Clause 9.2.2.3 | +| 2 | CHOICE Secondary Node Type | STRUCTURE | | | | +| 3 | >Secondary Node gNB | STRUCTURE | | | <i>Global gNB ID IE</i> in TS 38.423 [15] Clause 9.2.2.1 | +| 4 | >>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity IE</i> in TS 38.423 [15] Clause 9.2.2.4 | | +| 5 | >>gNB ID | ELEMENT | FALSE | <i>gNB ID IE</i> in TS 38.423 [15] Clause 9.2.2.1 | | +| 6 | >Secondary Node ng-eNB | STRUCTURE | | | <i>Global ng-eNB ID IE</i> in TS 38.423 [15] Clause 9.2.2.2 | +| 7 | >>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity IE</i> in TS 38.423 [15] Clause 9.2.2.4 | | +| 8 | >>ng-eNB ID | ELEMENT | FALSE | <i>Long Macro ng-eNB ID IE</i> in TS 38.423 [15] Clause 9.2.2.2 | | +| 9 | >Secondary Node en-gNB | STRUCTURE | | | <i>en-gNB IE</i> in TS 36.423 [17] Sec | +| 10 | >>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity IE</i> in TS 36.423 [17] Clause 9.2.4 | | +| 11 | >>en-gNB ID | ELEMENT | FALSE | <i>Global en-gNB ID IE</i> in TS 36.423 [17] Clause 9.2.4 | | +| 12 | List of PDU Session Resources to be modified | LIST | | | <i>PDU Session Resources To Be Modified List IE</i> in TS 38.423 [15] Clause 9.1.2.5 | +| 13 | >PDU Session Resource to be Modified Item | STRUCTURE | | | <i>PDU Session Resources To Be Modified Item IE</i> in TS 38.423 [15] Clause 9.1.2.5 | +| 14 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID IE</i> in TS 38.423 [15] Clause 9.2.3.18 | | +| 15 | >>PDU Session Resource Modification Info – SN-Terminated | STRUCTURE | | | <i>PDU Session Resource Modification Info – SN Terminated IE</i> in TS 38.423 [15] Clause 9.2.1.9 | +| 16 | >>>QoS Flows To Be Setup List | LIST | | | <i>QoS Flows To Be Setup List IE</i> in TS 38.423 [15] Clause 9.2.1.9 | +| 17 | >>>>QoS Flow Item | STRUCTURE | | | <i>QoS Flows To Be Setup Item IE</i> in TS 38.423 [15] Clause 9.2.1.9 | +| 18 | >>>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier IE</i> in TS 38.423 [15] Clause 9.2.3.10 | | +| 19 | >>>>>QoS Flow Mapping | ELEMENT | FALSE | <i>QoS Flow Mapping Indication IE</i> in TS | | + +| | | | | | | +|----|----------------------------------------------------------|-----------|-------|---------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------| +| | Indication | | | 38.423 [15] Clause 9.2.3.79 | | +| 20 | >>>>Redundant QoS Flow Indicator | ELEMENT | FALSE | | | +| 21 | >>>QoS Flows To Be Modified List | LIST | | | <i>QoS Flows To Be Modified List</i> IE in TS 38.423 [15] Clause 9.2.1.9 | +| 22 | >>>>QoS Flow Item | STRUCTURE | | | <i>QoS Flows To Be Modified Item</i> IE in TS 38.423 [15] Clause 9.2.1.9 | +| 23 | >>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 24 | >>>>QoS Flow Mapping Indication | ELEMENT | FALSE | <i>QoS Flow Mapping Indication</i> IE in TS 38.423 [15] Clause 9.2.3.79 | | +| 25 | >>>>Redundant QoS Flow Indicator | ELEMENT | FALSE | <i>Redundant QoS Flow Indicator</i> IE in TS 38.423 [15] Clause 9.2.3.118 | | +| 26 | >>>QoS Flows To Be Released List | LIST | | | <i>QoS Flows To Be Released List</i> IE in TS 38.423 [15] Clause 9.2.1.9 | +| 27 | >>>>QoS Flow Item | STRUCTURE | | | <i>QoS Flow With Cause Item</i> IE in TS 38.423 [15] Clause 9.2.1.4 | +| 28 | >>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 29 | >>>Default DRB allowed | ELEMENT | FALSE | <i>Default DRB Allowed</i> IE in TS 38.423 [15] Clause 9.2.3.93 | | +| 30 | >>PDU Session Resource Modification Info – MN-Terminated | STRUCTURE | | | <i>PDU Session Resource Modification Info – MN Terminated</i> IE in TS 38.423 [15] Clause 9.2.1.11 | +| 31 | >>>DRBs to be setup list | LIST | | | <i>DRBs To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.11 | +| 32 | >>>>DRBs to be setup item | STRUCTURE | | | <i>DRBs To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.11 | +| 33 | >>>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] Clause 9.3.1.16 | | +| 34 | >>>>>DRB QoS | STRUCTURE | | | | +| 35 | >>>>>PDCP Duplication Activation | ELEMENT | TRUE | <i>Duplication Activation</i> IE in TS 37.483 [21] Clause 9.2.3.71 | | +| 36 | >>>>>QoS Flows Mapped to DRB List | LIST | | | <i>QoS Flows Mapped to DRB List</i> IE in TS 37.483 [21] Clause 9.2.1.11 | + +| | | | | | | +|----|---------------------------------------------|-----------|-------|----------------------------------------------------------------------------|--------------------------------------------------------------------------| +| 37 | >>>>>QoS Flows Mapped to DRB Item | STRUCTURE | | | <i>QoS Flows Mapped To DRB Item</i> IE in TS 37.483 [21] Clause 9.2.1.11 | +| 38 | >>>>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 39 | >>>>>>QoS Flow Mapping Indication | ELEMENT | FALSE | <i>QoS Flow Mapping Indication</i> IE in TS 38.423 [15] Clause 9.2.3.79 | | +| 40 | >>>DRBs to be modified list | LIST | | | <i>DRBs To Be Modified List</i> IE in TS 37.483 [21] Clause 9.2.1.11 | +| 41 | >>>>DRB to be modified item | STRUCTURE | | | <i>DRBs To Be Modified Item</i> IE in TS 37.483 [21] Clause 9.2.1.11 | +| 42 | >>>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] Clause 9.3.1.16 | | +| 43 | >>>>>DRB QoS | STRUCTURE | | | | +| 44 | >>>>>PDCP Duplication Configuration | ELEMENT | FALSE | <i>PDCP Duplication Configuration</i> IE in TS 37.483 [21] Clause 9.2.3.86 | | +| 45 | >>>>>PDCP Duplication Activation | ELEMENT | FALSE | <i>Duplication Activation</i> IE in TS 37.483 [21] Clause 9.2.3.71 | | +| 46 | >>>>>QoS Flows Mapped to DRB List | LIST | | | <i>Flow Mapping Information</i> IE in TS 37.483 [21] Clause 9.3.1.26 | +| 47 | >>>>>>QoS Flows Mapped to DRB Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.25 | +| 48 | >>>>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 49 | >>>>>>QoS Flow Mapping Indication | ELEMENT | FALSE | <i>QoS Flow Mapping Indication</i> IE in TS 38.423 [15] Clause 9.2.3.79 | | +| 50 | >>>DRBs to be released list | LIST | | | <i>DRBs To Be Released List</i> IE in TS 38.423 [15] Clause 9.2.1.28 | +| 51 | >>>>DRB to be released item | STRUCTURE | | | <i>DRBs To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.11 | +| 52 | >>>>>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 37.483 [21] Clause 9.3.1.16 | | +| 53 | List of PDU Session Resources to be deleted | LIST | | | <i>PDU Session Resources To Be Released List</i> IE in TS 38.423 [15] | + +| | | | | | | +|----|------------------------------------------|-----------|-------|------------------------------------------------------------|-------------------------------------------------------------------------| +| | | | | | Clause 9.1.2.5 | +| 54 | >PDU Session Resource to be deleted Item | STRUCTURE | | | <i>PDU Session Resource To Be Released Item IE</i> | +| 55 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID IE</i> in TS 38.423 [15] Clause 9.2.3.18 | | +| 56 | List of E-RABs to be Modified | LIST | | | <i>E-RABs To Be Modified List IE</i> in TS 36.423 [17] Clause 9.1.4.5 | +| 57 | >E-RAB to be Modified Item | STRUCTURE | | | <i>E-RAB To Be Modified Item IE</i> in TS 36.423 [17] Clause 9.1.4.5 | +| 58 | >>E-RAB ID | ELEMENT | TRUE | <i>E-RAB ID IE</i> in TS 36.423 [17] Clause 9.2.23 | | +| 59 | >>EN-DC Resource Configuration | STRUCTURE | | | <i>EN-DC Resource Configuration IE</i> in TS 36.423 [17] Clause 9.2.108 | +| 60 | >>>PDCP at SgNB | ELEMENT | FALSE | <i>PDCP at SgNB IE</i> in TS 36.423 [17] Clause 9.2.108 | | +| 61 | >>>MCG Resources | ELEMENT | FALSE | <i>MCG resources IE</i> in TS 36.423 [17] Clause 9.2.108 | | +| 62 | >>>SCG Resources | ELEMENT | FALSE | <i>SCG resources IE</i> in TS 36.423 [17] Clause 9.2.108 | | +| 63 | List of E-RABs to be Released | LIST | | | <i>E-RABs To Be Released List IE</i> in TS 36.423 [17] Clause 9.1.4.5 | +| 64 | >E-RAB to be Released Item | STRUCTURE | | | <i>E-RABs To Be Released Item IE</i> in TS 36.423 [17] Clause 9.1.4.5 | +| 65 | >>E-RAB ID | ELEMENT | TRUE | <i>E-RAB ID IE</i> in TS 36.423 [17] Clause 9.2.23 | | + +### 8.4.6.3 PSCell Change control for Secondary Cell Group + +Upon receiving the *RIC Control Request* message, in the case of intra-SN PSCell change, the E2 node shall invoke procedures related to PSCell Change Control, such as *Dual Connectivity Secondary Node Modification*, *UE Context Modification*, *RRC Message Transfer*, etc. In the case of inter-SN PSCell change, the E2 node shall invoke procedures such as *Dual Connectivity Secondary Node Release* (MN/SN-initiated) or *SN Change* (only SN-initiated), *Bearer Context Modification*, *UE Context Modification*, *RRC Message Transfer*, etc. The E2 node then includes the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------------|--------------------------|----------|-----------------------------------------------------------------|---------------------------------------------------------------------------------| +| 1 | Target PSCell ID | STRUCTURE | | | <i>Target Cell Global ID</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 2 | >CHOICE Target Cell | STRUCTURE | | | <i>Target Cell</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 3 | >>NR Cell | STRUCTURE | | | <i>NR</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 4 | >>>NR CGI | ELEMENT | FALSE | <i>NR CGI</i> IE in TS 38.423 [15] Clause 9.2.2.7 | | +| 5 | >>E-UTRA Cell | STRUCTURE | | | <i>E-UTRA</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 6 | >>>E-UTRA CGI | ELEMENT | FALSE | <i>E-UTRA CGI</i> IE in TS 38.423 [15] Clause 9.2.2.8 | | +| 7 | Secondary Node ID | STRUCTURE | | | <i>Global NG-RAN Node ID</i> IE in TS 38.423 [15] Clause 9.2.2.3 | +| 8 | >CHOICE Secondary Node Type | STRUCTURE | | | | +| 9 | >>Secondary Node gNB | STRUCTURE | | | <i>Global gNB ID</i> IE in TS 38.423 [15] Clause 9.2.2.1 | +| 10 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.423 [15] Clause 9.2.2.4 | | +| 11 | >>>gNB ID | ELEMENT | FALSE | <i>gNB ID</i> IE in TS 38.423 [15] Clause 9.2.2.1 | | +| 12 | >>Secondary Node ng-eNB | STRUCTURE | | | <i>Global ng-eNB ID</i> IE in TS 38.423 [15] Clause 9.2.2.2 | +| 13 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.423 [15] Clause 9.2.2.4 | | +| 14 | >>>ng-eNB ID | ELEMENT | FALSE | <i>Long Macro ng-eNB ID</i> IE in TS 38.423 [15] Clause 9.2.2.2 | | +| 15 | >>Secondary Node en-gNB | STRUCTURE | | | <i>en-gNB</i> IE in TS 36.423 [17] Sec | +| 16 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 36.423 [17] Clause 9.2.4 | | +| 17 | >>>en-gNB ID | ELEMENT | FALSE | <i>Global en-gNB ID</i> IE in TS 36.423 [17] Clause 9.2.4 | | +| 18 | PDU Session SN Change Required List | LIST | | | <i>PDU Session SN Change Required List</i> IE in TS 38.423 [15] Clause 9.1.2.11 | +| 19 | >PDU Session SN Change Required Item | STRUCTURE | | | <i>PDU Session SN Change Required Item</i> IE in TS 38.423 [15] Clause 9.1.2.11 | +| 20 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.3.18 | | +| 21 | >>List of QoS flows in the PDU session | LIST | | | <i>QoS Flows To Be Setup List</i> IE in TS 38.423 [15] Clause | + +| | | | | | | +|----|----------------------------------|-----------|------|-----------------------------------------------------------------|------------------------------------------------------------------------------| +| | | | | | 9.2.1.1 | +| 22 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 23 | >>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 24 | List of DRBs for PSCell handover | LIST | | | <i>DRB to Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 25 | >DRB item for PSCell handover | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 26 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.473 [19] Clause 9.3.1.8 | | +| 27 | >>List of QoS flows in the DRB | LIST | | | <i>QoS Flows Information To Be Setup</i> IE in TS 37.483 [21] Clause 9.3.3.2 | +| 28 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.25 | +| 29 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] Clause 9.3.1.24 | | + +#### 8.4.6.4 DC Secondary Node Change Control + +Upon receiving the RIC Control Request message, the E2 node shall invoke procedures such as Dual Connectivity Secondary Node Release (MN/SN-initiated) or SN Change (only SN-initiated), Bearer Context Modification, UE Context Modification, RRC Message Transfer, etc. and includes the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------------|--------------------------|----------|-----------------------------------------------------------------|---------------------------------------------------------------------------------| +| 1 | Target PSCell ID | STRUCTURE | | | <i>Target Cell Global ID</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 2 | >CHOICE Target Cell | STRUCTURE | | | <i>Target Cell</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 3 | >>NR Cell | STRUCTURE | | | <i>NR</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 4 | >>>NR CGI | ELEMENT | FALSE | <i>NR CGI</i> IE in TS 38.423 [15] Clause 9.2.2.7 | | +| 5 | >>E-UTRA Cell | STRUCTURE | | | <i>E-UTRA</i> IE in TS 38.423 [15] Clause 9.2.3.25 | +| 6 | >>>E-UTRA CGI | ELEMENT | FALSE | <i>E-UTRA CGI</i> IE in TS 38.423 [15] Clause 9.2.2.8 | | +| 7 | Target Secondary Node ID | STRUCTURE | | | <i>Target S-NG-RAN node ID</i> IE in TS 38.423 [15] Clause 9.1.2.11 | +| 8 | >CHOICE Target Secondary Node Type | STRUCTURE | | | | +| 9 | >>Secondary Node gNB | STRUCTURE | | | <i>Global gNB ID</i> IE in TS 38.423 [15] Clause 9.2.2.1 | +| 10 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.423 [15] Clause 9.2.2.4 | | +| 11 | >>>gNB ID | ELEMENT | FALSE | <i>gNB ID</i> IE in TS 38.423 [15] Clause 9.2.2.1 | | +| 12 | >>Secondary Node ng-eNB | STRUCTURE | | | <i>Global ng-eNB ID</i> IE in TS 38.423 [15] Clause 9.2.2.2 | +| 13 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 38.423 [15] Clause 9.2.2.4 | | +| 14 | >>>ng-eNB ID | ELEMENT | FALSE | <i>Long Macro ng-eNB ID</i> IE in TS 38.423 [15] Clause 9.2.2.2 | | +| 15 | >>Secondary Node en-gNB | STRUCTURE | | | <i>en-gNB</i> IE in TS 36.423 [17] Sec | +| 16 | >>>PLMN Identity | ELEMENT | FALSE | <i>PLMN Identity</i> IE in TS 36.423 [17] Clause 9.2.4 | | +| 17 | >>>en-gNB ID | ELEMENT | FALSE | <i>Global en-gNB ID</i> IE in TS 36.423 [17] Clause 9.2.4 | | +| 18 | PDU Session SN Change Required List | LIST | | | <i>PDU Session SN Change Required List</i> IE in TS 38.423 [15] Clause 9.1.2.11 | +| 19 | >PDU Session SN Change Required Item | STRUCTURE | | | <i>PDU Session SN Change Required Item</i> IE in TS 38.423 [15] Clause 9.1.2.11 | +| 20 | >>PDU Session ID | ELEMENT | TRUE | <i>PDU Session ID</i> IE in TS 38.423 [15] Clause 9.2.3.18 | | + +| | | | | | | +|----|----------------------------------------|-----------|------|-----------------------------------------------------------------|------------------------------------------------------------------------------| +| 21 | >>List of QoS flows in the PDU session | LIST | | | <i>QoS Flows To Be Setup List</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 22 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow To Be Setup Item</i> IE in TS 38.423 [15] Clause 9.2.1.1 | +| 23 | >>>>QoS Flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 38.423 [15] Clause 9.2.3.10 | | +| 24 | List of DRBs for PSCell handover | LIST | | | <i>DRB to Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 25 | >DRB item for PSCell handover | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 26 | >>DRB ID | ELEMENT | TRUE | <i>DRB ID</i> IE in TS 38.473 [19] Clause 9.3.1.8 | | +| 27 | >>List of QoS flows in the DRB | LIST | | | <i>QoS Flows Information To Be Setup</i> IE in TS 37.483 [21] Clause 9.3.3.2 | +| 28 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.25 | +| 29 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] Clause 9.3.1.24 | | + +## 8.4.7 Carrier Aggregation Control + +### 8.4.7.1 Secondary cell Addition control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to Secondary cell Addition Control, such as *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------------|--------------------------|----------|-----------------------------------------------------------------|------------------------------------------------------------------------------| +| 1 | List of secondary cells to be setup | LIST | | | <i>Scell To Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 2 | >Secondary cell to be setup Item | STRUCTURE | | | <i>Scell To Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 3 | >>Scell Cell Global ID | ELEMENT | FALSE | <i>Scell ID</i> IE in TS 38.473 [19] Clause 9.2.2.1 | | +| 4 | >>Scell UL Configured | ELEMENT | FALSE | <i>Cell UL Configured</i> IE in TS 38.473 [19] Clause 9.3.1.33 | | +| 5 | List of DRBs to be served using SCells | LIST | | | <i>DRB to Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 6 | >DRB item | STRUCTURE | | | <i>DRB to Be Setup Item</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 7 | >>DRB ID | ELEMENT | TRUE | DRB ID IE in TS 38.473 [19] Clause 9.3.1.8 | | +| 8 | >>List of QoS flows in the DRB | LIST | | | <i>QoS Flows Information To Be Setup</i> IE in TS 37.483 [21] Clause 9.3.3.2 | +| 9 | >>>QoS flow Item | STRUCTURE | | | <i>QoS Flow Item</i> IE in TS 37.483 [21] Clause 9.3.1.25 | +| 10 | >>>>QoS flow Identifier | ELEMENT | TRUE | <i>QoS Flow Identifier</i> IE in TS 37.483 [21] Clause 9.3.1.24 | | + +## 8.4.7.2 Secondary cell Modification control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to Secondary cell Modification Control, such as *UE Context Management*, *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-------------------------------------|--------------------------|----------|----------------------------------------------------------------|-------------------------------------------------------------------------| +| 1 | List of secondary cells to be setup | LIST | | | <i>Scell To Be Setup List</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 2 | >Secondary cell to be setup Item | STRUCTURE | | | <i>Scell To Be Setup Item Ies</i> IE in TS 38.473 [19] Clause 9.2.2.1 | +| 3 | >>Scell Global ID | ELEMENT | FALSE | <i>Scell ID</i> IE in TS 38.473 [19] Clause 9.2.2.1 | | +| 4 | >>Scell UL Configured | ELEMENT | FALSE | <i>Cell UL Configured</i> IE in TS 38.473 [19] Clause 9.3.1.33 | | +| 5 | List of Scells to be removed | LIST | | | <i>SCell To Be Removed List</i> IE in TS 38.473 [19] Clause 9.2.2.7 | +| 6 | >Scell to be removed Item | STRUCTURE | | | <i>SCell to Be Removed Item IEs</i> IE in TS 38.473 [19] Clause 9.2.2.7 | +| 7 | >>Scell Global ID | ELEMENT | FALSE | <i>Scell ID</i> IE in TS 38.473 [19] Clause 9.2.2.1 | | + +## 8.4.8 Idle Mode Mobility Control + +### 8.4.8.1 Cell reselection priority control + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to cell reselection priority control, such as *RRC Message Transfer*, etc. and include the IEs corresponding to one or more of parameters described below in the related interface messages. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------|--------------------------|----------|--------------------------------------------------------|---------------------------------------------------------| +| 1 | Cell Reselection Priorities | STRUCTURE | | | <i>IdleModeMobilityControlInfo</i> IE in TS 36.331 [23] | +| 2 | >Frequency Priority List E-UTRA | LIST | | | <i>FreqPriorityListEUTRA</i> IE in TS 38.331 [22] | +| 3 | >>Frequency Priority Item E-UTRA | STRUCTURE | | | <i>FreqPriorityEUTRA</i> IE in TS 38.331 [22] | +| 4 | >>>Carrier Frequency | ELEMENT | FALSE | <i>carrierFreq</i> IE in TS 38.331 [22] | | +| 5 | >>>Cell Reselection Priority | ELEMENT | FALSE | <i>cellReselectionPriority</i> IE in TS 38.331 [22] | | +| 6 | >>>Cell Reselection Sub Priority | ELEMENT | FALSE | <i>cellReselectionSubPriority</i> IE in TS 38.331 [22] | | +| 7 | >Frequency Priority List NR | LIST | | | <i>FreqPriorityListNR</i> IE in TS 38.331 [22] | +| 8 | >>Frequency Priority Item NR | STRUCTURE | | | <i>FreqPriorityNR</i> IE in TS 38.331 [22] | +| 9 | >>>Carrier Frequency | ELEMENT | FALSE | <i>carrierFreq</i> IE in TS 38.331 [22] | | +| 10 | >>>Cell Reselection Priority | ELEMENT | FALSE | <i>cellReselectionPriority</i> IE in TS 38.331 [22] | | +| 11 | >>>Cell Reselection Sub Priority | ELEMENT | FALSE | <i>cellReselectionSubPriority</i> IE in TS 38.331 [22] | | +| 12 | >T-320 timer expiry | ELEMENT | FALSE | <i>t320</i> IE in TS 38.331 [22] | | + +## 8.4.9 UE identification, information and assignment + +### 8.4.9.1 UE to Explicit UE list assignment command + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to the assignment of a target UE to an Explicit UE List and modify the corresponding Explicit UE List according to the contents of the RIC Control Message based on the following RAN Parameters. + +*RIC Control Message* IE contents: + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------------------|--------------------------|----------|--------------------------|-----------------------------------------------------------------------------------------------------------| +| 1 | <i>Explicit UE list identifier</i> | ELEMENT | FALSE | INTEGER | Identifier previously announced by E2 Node Set to 0 or not present when used with assignment command = 3 | +| 2 | Assignment command | ELEMENT | FALSE | INTEGER | 1= Add UE<br>2= Remove UE<br>3= Send list of supported <i>Explicit UE list</i><br>4= Change UE assignment | + +Upon processing the procedures related to the assignment of a target UE to an Explicit UE List, the E2 Node shall use the optional *RIC Control Outcome* IE to report the call processing outcome to the Near-RT RIC as a response to the control action: + +**i) If the outcome is successful** + +For Assignment command = 1, 2 and 4. Not used + +For Assignment command = 3, the following parameters are to be used: + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-------------------------------------------|--------------------------|----------|--------------------------|--------------------------------------------------------------| +| 1001 | List of supported <i>Explicit UE list</i> | LIST | | | To provide a list of Explicit UE List records | +| 1002 | > <i>Explicit UE list</i> information | STRUCTURE | | | To provide information on a specific Explicit UE List record | +| 1003 | >> <i>Explicit UE list identifier</i> | ELEMENT | TRUE | INTEGER | Identifier of Explicit UE List | +| 1004 | >> <i>Explicit UE list name</i> | ELEMENT | FALSE | PRINTABLE STRING | Name of Explicit UE List | +| 1005 | >> <i>Explicit UE list description</i> | ELEMENT | FALSE | PRINTABLE STRING | Text description of Explicit UE list | + +**ii) If the outcome is not successful** + +The following RAN Parameters are to be used for all assignment commands: + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------|--------------------------|----------|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1010 | Failure Cause | ELEMENT | FALSE | INTEGER | 0= reserved<br>1= UE already assigned to Explicit UE list<br>2 = Explicit UE list not known<br>3= UEID not known<br>4 = Other<br>5 = Explicit UE List not supported | + +### 8.4.9.2 UE information request + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to UE information request according to the RAN Parameter IDs listed in the contents of the RIC Control Message E2SM-RC Control Message Format 4 optional *RAN Parameter Definition* IE based on RAN Parameters: + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------------------|--------------------------|----------|--------------------------|-----------------------| +| UE information | Defined in clause 8.1.3 RAN Parameters for UE information | | | | | + +Upon processing the procedures related to handling of UE information request, the E2 Node shall use the optional *RIC Control Outcome* IE to report the call processing outcome to the Near-RT RIC as a response to the control action: + +#### i) If the outcome is successful + +| RAN Parameter Category | RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------------|-----------------------------------------------------------|--------------------|--------------------------|----------|--------------------------|-----------------------| +| UE information | Defined in clause 8.1.3 RAN Parameters for UE information | | | | | | + +#### ii) If the outcome is not successful + +| RAN Parameter Category | RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------------|---------------------------|--------------------|--------------------------|----------|--------------------------|-----------------------| +| Failure cause | Defined in clause 8.4.9.1 | | | | | | + +### 8.4.9.3 UE identification request + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to UE identification request according to the contents of the *RIC Control Header* IE. + +Upon processing the procedures related to handling of UE Identification request, the E2 Node shall use the optional *RIC Control Outcome* IE to report the call processing outcome to the Near-RT RIC as a response to the control action: + +#### i) If the outcome is successful + +| RAN Parameter Category | RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------------|-----------------------------------------------------------------------------|--------------------|--------------------------|----------|--------------------------|-----------------------| +| UE ID list | Defined in clause 8.1.3 RAN Parameters for UE identification for UE ID List | | | | | | + +#### ii) If the outcome is not successful + +| RAN Parameter Category | RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------------|---------------------------|--------------------|--------------------------|----------|--------------------------|-----------------------| +| Failure cause | Defined in clause 8.4.9.1 | | | | | | + +## 8.4.10 Measurement Reporting Configuration Control + +### 8.4.10.1 Add MR Configuration + +Upon receiving the *RIC Control Request* message with the *Measurement Report Configuration Control* Service Style and the *Add MR Configuration* control action, the E2 node shall invoke relevant RRC procedures to configure + +Measurement Report to the UE. E2 Node shall include the IEs corresponding to one or more of RAN parameters described below in the related RRC or NI interface messages. + +In the case of UE group-based control action, the above RRC procedure(s) is invoked individually for each individual UE within the group. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------------------|--------------------------|----------|------------------------------------------------|-----------------------------------------------------------------------------------------------------------------| +| 1 | List of Measurement Objects to Add | LIST | | | <i>measObjectToAddModList</i> IE in TS 38.331 Sec 6 | +| 2 | 1>Measurement Object to Add Item | STRUCTURE | | | <i>MeasObjectToAddMod</i> IE in TS 38.331 Sec 6 | +| 3 | 2>MO Sequence ID | ELEMENT | TRUE | INTEGER (1..64) | This is the unique ID used by the RIC for the measurement object it seeks to add via the control service style. | +| 4 | 2>CHOICE <i>MO Type</i> | STRUCTURE | | | <i>measObject</i> IE in TS 38.331 Sec 6 | +| 11 | 3> <i>NR MO</i> | STRUCTURE | | | <i>MeasObjectNR</i> IE in TS 38.331 Sec 6 | +| 12 | 4>SSB Frequency | ELEMENT | TRUE | <i>ARFCN-ValueNR</i> IE in TS 38.331 Sec 6 | | +| 13 | 4>SSB Subcarrier spacing | ELEMENT | FALSE | <i>subcarrierSpacing</i> IE in TS 38.331 Sec 6 | | +| 14 | 4>SSB Primary MTC | STRUCTURE | | | <i>smtc1</i> IE in TS 38.331 Sec 6 | +| 15 | 5>CHOICE <i>Periodicity and Offset</i> | STRUCTURE | | | <i>periodicityAndOffset</i> IE in TS 38.331 Sec 6 | +| 16 | 6>Sub-frame 5 | ELEMENT | FALSE | <i>sf5</i> IE in TS 38.331 Sec 6 | | +| 17 | 6>Sub-frame 10 | ELEMENT | FALSE | <i>sf10</i> IE in TS 38.331 Sec 6 | | +| 18 | 6>Sub-frame 20 | ELEMENT | FALSE | <i>sf20</i> IE in TS 38.331 Sec 6 | | +| 19 | 6>Sub-frame 40 | ELEMENT | FALSE | <i>sf40</i> IE in TS 38.331 Sec 6 | | +| 20 | 6>Sub-frame 80 | ELEMENT | FALSE | <i>sf80</i> IE in TS 38.331 Sec 6 | | +| 21 | 6>Sub-frame 160 | ELEMENT | FALSE | <i>sf160</i> IE in TS 38.331 Sec 6 | | +| 22 | 5>Duration | ELEMENT | FALSE | <i>duration</i> IE in TS 38.331 Sec 6 | | +| 31 | 4>SSB Secondary MTC | STRUCTURE | | | <i>smtc2</i> IE in TS 38.331 Sec 6 | +| 32 | 5>List of cells | LIST | | | <i>pci-List</i> IE in TS 38.331 Sec 6 | +| 33 | 6>Cell Item | STRUCTURE | | | <i>physCellID</i> IE in TS 38.331 Sec 6 | + +| | | | | | | +|----|---------------------------------------------|-----------|-------|------------------------------------------------------|------------------------------------------------------------| +| 34 | 7>PCI | ELEMENT | TRUE | <i>physCellID</i> IE in TS 38.331 Sec 6 | | +| 35 | 5>Periodicity | ELEMENT | FALSE | <i>periodicity</i> IE in TS 38.331 Sec 6 | | +| 36 | 4>Reference Frequency CSI – RS | ELEMENT | TRUE | <i>refFreqCSI-RS</i> IE in TS 38.331 Sec 6 | | +| 37 | 4>Reference Signal Config | STRUCTURE | | | <i>referenceSignalConfig</i> IE in TS 38.331 Sec 6 | +| 38 | 5>SSB Configuration Mobility | STRUCTURE | | | <i>SSB-ConfigMobility</i> IE in TS 38.331 Sec 6 | +| 40 | 6>CHOICE SSB To Measure for setup | STRUCTURE | | | <i>SSB-ToMeasure</i> IE in TS 38.331 Sec 6 | +| 41 | 7>Short Bitmap | ELEMENT | FALSE | <i>shortBitmap</i> IE in TS 38.331 Sec 6 | | +| 42 | 7>Medium Bitmap | ELEMENT | FALSE | <i>mediumBitmap</i> IE in TS 38.331 Sec 6 | | +| 43 | 7>Long Bitmap | ELEMENT | FALSE | <i>longBitmap</i> IE in TS 38.331 Sec 6 | | +| 44 | 6>Derive SSB Index From Cell | ELEMENT | FALSE | <i>deriveSSB-IndexFromCell</i> IE in TS 38.331 Sec 6 | | +| 45 | 6>SS RSSI Measurement | STRUCTURE | | | <i>ss-RSSI-Measurement</i> IE in TS 38.331 Sec 6 | +| 46 | 7>Measurement Slots | ELEMENT | FALSE | <i>measurementSlots</i> IE in TS 38.331 Sec 6 | | +| 47 | 7>End Symbol | ELEMENT | FALSE | <i>endSymbol</i> IE in TS 38.331 Sec 6 | | +| 50 | 6>CSI RS Resource Config Mobility for setup | STRUCTURE | | | <i>csi-rs-ResourceConfigMobility</i> IE in TS 38.331 Sec 6 | +| 51 | 7>Reference Serving cell Index | ELEMENT | TRUE | <i>refServingIndex</i> IE in TS 38.331 Sec 6 | | +| 52 | 7>Sub carrier spacing | ELEMENT | FALSE | <i>subcarrierSpacing</i> IE in TS 38.331 Sec 6 | | +| 53 | 7>CSI RS Cell List Mobility | LIST | | | <i>csi-RS-CellList-Mobility</i> IE in TS 38.331 Sec 6 | +| 54 | 8>CSI RS Cell Mobility | STRUCTURE | | | <i>CSI-RS-CellMobility</i> IE in TS 38.331 Sec 6 | +| 55 | 9>Physical Cell ID | ELEMENT | TRUE | <i>PhysCellID</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|----|---------------------------------------|-----------|-------|-----------------------------------------------|-----------------------------------------------------------| +| 56 | 9>CSI RS Measurement Bandwidth | STRUCTURE | | | <i>csi-rs-Measurement BW</i> IE in TS 38.331 Sec 6 | +| 57 | 10>Number of PRBs | ELEMENT | FALSE | <i>nrofPRBs</i> IE in TS 38.331 Sec 6 | | +| 58 | 10>Start PRB | ELEMENT | FALSE | <i>startPRB</i> IE in TS 38.331 Sec 6 | | +| 59 | 9>Density | ELEMENT | FALSE | <i>density</i> IE in TS 38.331 Sec 6 | | +| 60 | 9>CSI RS Resource List Mobility | LIST | | | <i>csi-rs-ResourceList-Mobility</i> IE in TS 38.331 Sec 6 | +| 61 | 10>CSI RS Resource Item Mobility | STRUCTURE | | | <i>CSI-RS-Resource-Mobility</i> IE in TS 38.331 Sec 6 | +| 62 | 11>CSI RS Index | ELEMENT | TRUE | <i>csi-RS-Index</i> IE in TS 38.331 Sec 6 | | +| 63 | 11>CHOICE Slot Config | STRUCTURE | | | <i>slotConfig</i> IE in TS 38.331 Sec 6 | +| 64 | 12>ms4 | ELEMENT | FALSE | <i>ms4</i> IE in TS 38.331 Sec 6 | | +| 65 | 12>ms5 | ELEMENT | FALSE | <i>ms5</i> IE in TS 38.331 Sec 6 | | +| 66 | 12>ms10 | ELEMENT | FALSE | <i>ms10</i> IE in TS 38.331 Sec 6 | | +| 67 | 12>ms20 | ELEMENT | FALSE | <i>ms20</i> IE in TS 38.331 Sec 6 | | +| 68 | 12>ms40 | ELEMENT | FALSE | <i>ms40</i> IE in TS 38.331 Sec 6 | | +| 69 | 11>Associated SSB | STRUCTURE | | | <i>associatedSSB</i> IE in TS 38.331 Sec 6 | +| 70 | 12>SSB Index | ELEMENT | TRUE | <i>ssb-Index</i> IE in TS 38.331 Sec 6 | | +| 71 | 12>Is Quasi colocated | ELEMENT | FALSE | <i>isQuasiColocated</i> IE in TS 38.331 Sec 6 | | +| 72 | 11>CHOICE Frequency Domain Allocation | STRUCTURE | | | <i>frequencyDomainAllocation</i> IE in TS 38.331 Sec 6 | +| 73 | 12>Frequency | ELEMENT | FALSE | <i>row1</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | | +|----|---------------------------------------------------|---------------------------------------------------------------------------|-----------|-------|-----------------------------------------------------------------|-------------------------------------------------------------------------| +| | | ncy<br>Do<br>mai<br>n<br>Allo<br>cati<br>on<br>Ro<br>w 1 | | | | | +| 74 | | 12>Fre<br>que<br>ncy<br>Do<br>mai<br>n<br>Allo<br>cati<br>on<br>Ro<br>w 2 | ELEMENT | FALSE | row2 IE in TS 38.331 Sec 6 | | +| 75 | | 11>Firs<br>t OFDM<br>Symbol<br>in Time<br>Domain | ELEMENT | FALSE | firstOFDMSy<br>mbolInTimeD<br>omain IE in<br>TS 38.331<br>Sec 6 | | +| 76 | | 11>Seq<br>uence<br>Genera<br>tion<br>Config | ELEMENT | FALSE | sequenecGen<br>erationConfig<br>IE in TS<br>38.331 Sec 6 | | +| 77 | 4>Absolute Threshold SSB –<br>Block Consolidation | | STRUCTURE | | | absThreshSS<br>-<br>BlocksConsol<br>idation IE in<br>TS 38.331<br>Sec 6 | +| 78 | 5>Block Consolidation<br>Threshold RSRP | | ELEMENT | FALSE | RSRP-Range<br>IE in TS<br>38.331 Sec 6 | | +| 79 | 5>Block Consolidation<br>Threshold RSRQ | | ELEMENT | FALSE | RSRQ-Range<br>IE in TS<br>38.331 Sec 6 | | +| 80 | 5>Block Consolidation<br>Threshold SINR | | ELEMENT | FALSE | SINR-Range<br>IE in TS<br>38.331 Sec 6 | | +| 81 | 4>Absolute Threshold CSI<br>RS Consolidation | | STRUCTURE | | | absThreshCS<br>I-RS-<br>Consolidation<br>IE in TS<br>38.331 Sec 6 | +| 82 | 5>RS Consolidation<br>Threshold RSRP | | ELEMENT | FALSE | RSRP-Range<br>IE in TS<br>38.331 Sec 6 | | +| 83 | 5>RS Consoldation<br>Threshold RSRQ | | ELEMENT | FALSE | RSRQ-Range<br>IE in TS<br>38.331 Sec 6 | | +| 84 | 5>RS Consolidated<br>Threshold SINR | | ELEMENT | FALSE | SINR-Range<br>IE in TS<br>38.331 Sec 6 | | +| 91 | 4>Number of SS blocks to<br>average | | ELEMENT | FALSE | nrofSS-<br>BlocksToAver<br>age IE in TS<br>38.331 Sec 6 | | +| 92 | 4>Number of CSI RS<br>Resources to average | | ELEMENT | FALSE | nrofCSI-RS-<br>ResouresToA<br>verage IE in | | + +| | | | | | | +|-----|-------------------------------------|-----------|-------|--------------------------------------------------------|---------------------------------------------------------| +| | | | | TS 38.331<br>Sec 6 | | +| 93 | 4>Quantity Config Index | ELEMENT | TRUE | <i>quantityConfigIndex</i> IE in<br>TS 38.331<br>Sec 6 | | +| 100 | 4>Q-Offset MO Range<br>Sequence | STRUCTURE | | | <i>offsetMO</i> IE<br>in TS 38.331<br>Sec 6 | +| 101 | 5>RSRP Offset SSB | ELEMENT | FALSE | <i>rsrpOffsetSSB</i> IE in TS<br>38.331 Sec 6 | | +| 102 | 5>RSRQ Offset SSB | ELEMENT | FALSE | <i>rsrqOffsetSSB</i> IE in TS<br>38.331 Sec 6 | | +| 103 | 5>SINR Offset SSB | ELEMENT | FALSE | <i>sinrOffsetSSB</i> IE in TS<br>38.331 Sec 6 | | +| 104 | 5>RSRP Offset CSI RS | ELEMENT | FALSE | <i>rsrpOffsetCSI-<br/>RS</i> IE in TS<br>38.331 Sec 6 | | +| 105 | 5>RSRQ Offset CSI RS | ELEMENT | FALSE | <i>rsrqOffsetCSI-<br/>RS</i> IE in TS<br>38.331 Sec 6 | | +| 106 | 5>SINR Offset CSI RS | ELEMENT | FALSE | <i>sinrOffsetCSI-<br/>RS</i> IE in TS<br>38.331 Sec 6 | | +| 110 | 4>Cells to Add List | LIST | | | <i>CellsToAddModList</i> IE in<br>TS 38.331<br>Sec 6 | +| 111 | 5>Cell to Add Item | STRUCTURE | | | <i>CellsToAdd</i> IE in TS<br>38.331 Sec 6 | +| 112 | 6>Cell to Add -<br>Physical Cell ID | ELEMENT | TRUE | <i>physCellID</i> IE in TS 38.331<br>Sec 6 | | +| 113 | 6>Cell Individual<br>Offset | STRUCTURE | | | <i>cellIndividualOffset</i> IE in<br>TS 38.331<br>Sec 6 | +| 115 | 7>RSRP Offset<br>SSB | ELEMENT | FALSE | <i>rsrpOffsetSSB</i> IE in TS<br>38.331 Sec 6 | | +| 116 | 7>RSRQ Offset<br>SSB | ELEMENT | FALSE | <i>rsrqOffsetSSB</i> IE in TS<br>38.331 Sec 6 | | +| 117 | 7>SINR Offset<br>SSB | ELEMENT | FALSE | <i>sinrOffsetSSB</i> IE in TS<br>38.331 Sec 6 | | +| 118 | 7>RSRP Offset<br>CSI RS | ELEMENT | FALSE | <i>rsrpOffsetCSI-<br/>RS</i> IE in TS<br>38.331 Sec 6 | | +| 119 | 7>RSRQ Offset<br>CSI RS | ELEMENT | FALSE | <i>rsrqOffsetCSI-<br/>RS</i> IE in TS<br>38.331 Sec 6 | | +| 120 | 7>SINR Offset<br>CSI RS | ELEMENT | FALSE | <i>sinrOffsetCSI-<br/>RS</i> IE in TS<br>38.331 Sec 6 | | +| 125 | 4>Black cells to Add List | LIST | | | <i>blackCellsToAddModList</i> IE in TS<br>38.331 Sec 6 | +| 126 | 5>Black cell to Add Item | STRUCTURE | | | <i>PCI-RangeElement</i> IE in TS<br>38.331 Sec 6 | + +| | | | | | | +|-----|-------------------------------------------------|-----------|-------|---------------------------------------------------|-----------------------------------------------------| +| 127 | 6>Black cell to Add – Physical Cell Range Index | ELEMENT | TRUE | <i>PCI-RangeIndex</i> IE in TS 38.331 Sec 6 | | +| 128 | 6>Physical Cell ID - Range | STRUCTURE | | | <i>PCI-Range</i> IE in TS 38.331 Sec 6 | +| 129 | 7>Physical Cell ID Start | ELEMENT | TRUE | <i>physCellId</i> IE in TS 38.331 Sec 6 | | +| 130 | 7>Physical Cell ID Range | ELEMENT | FALSE | <i>range</i> IE in TS 38.331 Sec 6 | | +| 135 | 4>White cells to Add List | LIST | | | <i>whiteCellsToAddModList</i> IE in TS 38.331 Sec 6 | +| 136 | 5>White cell to Add Item | STRUCTURE | | | <i>PCI-RangeElement</i> IE in TS 38.331 Sec 6 | +| 137 | 6>White cell to Add – Physical Cell Range Index | ELEMENT | TRUE | <i>PCI-RangeIndex</i> IE in TS 38.331 Sec 6 | | +| 138 | 6>Physical Cell ID - Range | STRUCTURE | | | <i>PCI-Range</i> IE in TS 38.331 Sec 6 | +| 129 | 7>Physical Cell ID Start | ELEMENT | TRUE | <i>PhysCellId</i> IE in TS 38.331 Sec 6 | | +| 130 | 7>Physical Cell ID Range | ELEMENT | FALSE | <i>range</i> IE in TS 38.331 Sec 6 | | +| 141 | 4>Frequency Band Indicator NR | ELEMENT | TRUE | <i>freqBandIndicatorNR</i> IE in TS 38.331 Sec 6 | | +| 142 | 4>Measurement Cycle Secondary cell | ELEMENT | FALSE | <i>measCycleSCell</i> IE in TS 38.331 Sec 6 | | +| 151 | 3> <i>E-UTRA MO</i> | STRUCTURE | | | <i>MeasObjectEUTRA</i> IE in TS 38.331 Sec 6 | +| 152 | 4>E-UTRA Carrier Frequency | ELEMENT | TRUE | <i>carrierFreq</i> IE in TS 38.331 Sec 6 | | +| 153 | 4>E-UTRA Allowed Measurement Bandwidth | ELEMENT | FALSE | <i>allowedMeasBandwidth</i> IE in TS 38.331 Sec 6 | | +| 171 | 4>List of E-UTRA cells to add | LIST | | | <i>cellsToAddModListEUTRA</i> IE in TS 38.331 Sec 6 | +| 172 | 5>E-UTRA Cell to add Item | STRUCTURE | | | | +| 173 | 6>E-UTRA Cell to add | STRUCTURE | | | <i>EUTRA-Cell</i> IE in TS 38.331 Sec 6 | +| 174 | 7>E-UTRA PCI to add | ELEMENT | TRUE | <i>EUTRA-PhysCellId</i> IE in TS 38.331 Sec 6 | | +| 175 | 7>E-UTRA Cell Individual Offset | ELEMENT | FALSE | <i>cellIndividualOffset</i> IE in | | + +| | | | | | | +|-----|--------------------------------------|-----------|-------|---------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------| +| | | | | TS 38.331<br>Sec 6 | | +| 191 | 4>List of E-UTRA black cells to add | LIST | | | <i>blackCellsToAddModList</i> IE in TS 38.331 Sec 6 | +| 192 | 5>E-UTRA black cell to add item | STRUCTURE | | | | +| 193 | 6>E-UTRA black cell to add | STRUCTURE | | | <i>EUTRA-BlackCell</i> IE in TS 38.331 Sec 6 | +| 194 | 7>E-UTRA Physical Cell ID Range | STRUCTURE | | | <i>EUTRA-PhysCellIdRange</i> IE in TS 38.331 Sec 6 | +| 195 | 8>E-UTRA PCI Start | ELEMENT | TRUE | <i>EUTRA-PhysCellId</i> IE in TS 38.331 Sec 6 | | +| 196 | 8>E-UTRA PCI Range | ELEMENT | FALSE | <i>range</i> IE in TS 38.331 Sec 6 | | +| 201 | 4>E-UTRA Presence Antenna Port 1 | ELEMENT | FALSE | <i>eutra-PresenceAntennaPort1</i> IE in TS 38.331 Sec 6 | | +| 205 | 4>E-UTRA Q Offset Range | ELEMENT | FALSE | <i>eutra-Q-OffsetRange</i> IE in TS 38.331 Sec 6 | | +| 210 | 4>Wideband RSRQ Measurement | ELEMENT | FALSE | <i>widebandRSRQ-Meas</i> IE in TS 38.331 Sec 6 | | +| 301 | List of Report Config Objects to Add | LIST | | | <i>ReportConfigToAddModList</i> IE in TS 38.331 Sec 6 | +| 302 | 1>Report Config Object to Add Item | STRUCTURE | | | <i>ReportConfigToAddMod</i> IE in TS 38.331 Sec 6 | +| 303 | 2>Report Config Sequence ID | ELEMENT | TRUE | INTEGER (1..64) | This is the unique ID used by the RIC for the measurement object it seeks to add via the control service style. | +| 304 | 2>CHOICE <i>Report Config Type</i> | STRUCTURE | | | <i>reportConfig</i> IE in TS 38.331 Sec 6 | +| 311 | 3> <i>NR Report Config</i> | STRUCTURE | | | <i>ReportConfigNR</i> IE in TS 38.331 Sec 6 | +| 312 | 4>CHOICE <i>Report Type</i> | STRUCTURE | | | <i>reportType</i> IE in TS 38.331 Sec 6 | +| 313 | 5>Periodical Report Config | STRUCTURE | | | <i>PeriodicalReportConfig</i> IE in TS 38.331 | + +| | | | | | | +|-----|-----------------------------------------------------------|-----------|-------|--------------------------------------------------------|-------------------------------------------------------| +| | | | | | Sec 6 | +| 314 | 6>NR RS Type | ELEMENT | FALSE | <i>NR-RS-Type</i> IE in TS 38.331 Sec 6 | | +| 315 | 6>NR Report Interval | ELEMENT | FALSE | <i>ReportInterval</i> IE in TS 38.331 Sec 6 | | +| 316 | 6>NR Report Amount | ELEMENT | FALSE | <i>reportAmount</i> IE in TS 38.331 Sec 6 | | +| 317 | 6>Measurement Report Quantity | STRUCTURE | | | <i>MeasReportQuantity</i> IE in TS 38.331 Sec 6 | +| 318 | 7>MR RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 319 | 7>MR RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | +| 320 | 7>MR SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | +| 321 | 6>Maximum number of Report cells | ELEMENT | FALSE | <i>maxReportCells</i> IE in TS 38.331 Sec 6 | | +| 322 | 6>Report Quantity Reference Signal – Indexes | STRUCTURE | | | <i>reportQuantityRS-Indexes</i> IE in TS 38.331 Sec 6 | +| 323 | 7>Report Qty RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 324 | 7>Report Qty RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | +| 325 | 7>Report Qty SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | +| 326 | 6>Maximum number of reference signals – Indexes to Report | ELEMENT | FALSE | <i>maxNrofRS-IndexesToReport</i> IE in TS 38.331 Sec 6 | | +| 327 | 6>Include Beam Measurements | ELEMENT | FALSE | <i>includeBeamMeasurements</i> IE in TS 38.331 Sec 6 | | +| 328 | 6>Use WhiteCellList | ELEMENT | FALSE | <i>useWhiteCellList</i> IE in TS 38.331 Sec 6 | | +| 331 | 5>Event Trigger Config | STRUCTURE | | | <i>EventTriggerConfig</i> IE in TS 38.331 Sec 6 | +| 332 | 6>CHOICE <i>Event ID</i> | STRUCTURE | | | <i>eventide</i> IE in TS 38.331 Sec 6 | +| 333 | 7>Event A1 | STRUCTURE | | | <i>eventA1</i> IE in TS 38.331 Sec 6 | +| 334 | 8>A1 Threshold | STRUCTURE | | | <i>a1-Threshold</i> IE in TS 38.331 Sec 6 | +| 335 | 9>CHOICE <i>A1 Threshold Type</i> | STRUCTURE | | | <i>MeasTriggerQuantity</i> IE in TS 38.331 Sec 6 | +| 336 | 10>A1 Threshold RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | <i>RSRP-Range</i> IE | +| 337 | 10>A1 Threshold RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | <i>RSRQ-Range</i> IE | + +| | | | | | | +|-----|-----------------------------|-----------|-------|--------------------------------------------|--------------------------------------------------------| +| | RSRQ | | | | | +| 338 | 10>A1 Threshold SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | <i>SINR-Range</i> IE | +| 339 | 9>A1 Report On Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 340 | 9>A1 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 341 | 9>A1 Time to Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 343 | 7>Event A2 | STRUCTURE | | | <i>eventA2</i> IE in TS 38.331 Sec 6 | +| 344 | 8>A2 Threshold | STRUCTURE | | | <i>A2-Threshold</i> IE in TS 38.331 Sec 6 | +| 345 | 9>CHOICE A2 Threshold Type | STRUCTURE | | | <i>MeasTriggerQuantity</i> IE in TS 38.331 Sec 6 | +| 346 | 10>A2 Threshold RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | <i>RSRP-Range</i> IE | +| 347 | 10>A2 Threshold RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | <i>RSRQ-Range</i> IE | +| 348 | 10>A2 Threshold SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | <i>SINR-Range</i> IE | +| 349 | 9>A2 Report On Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 350 | 9>A2 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 351 | 9>A2 Time to Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 353 | 7>Event A3 | STRUCTURE | | | <i>eventA3</i> IE in TS 38.331 Sec 6 | +| 354 | 8>A3 Offset | STRUCTURE | | | <i>a3-Threshold</i> IE in TS 38.331 Sec 6 | +| 355 | 9>CHOICE A3 Offset Type | STRUCTURE | | | <i>MeasTriggerQuantityOffset</i> IE in TS 38.331 Sec 6 | +| 356 | 10>A3 Threshold RSRP Offset | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 357 | 10>A3 Threshold RSRQ Offset | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | +| 358 | 10>A3 Threshold SINR Offset | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | +| 359 | 9>A3 Report On Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|-----|-----------------------------|-----------|-------|-----------------------------------------------|--------------------------------------------------| +| 360 | 9>A3 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 361 | 9>A3 Time to Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 362 | 9>Use White Cell List | ELEMENT | FALSE | <i>useWhiteCellList</i> IE in TS 38.331 Sec 6 | | +| 363 | 7>Event A4 | STRUCTURE | | | <i>eventA4</i> IE in TS 38.331 Sec 6 | +| 364 | 8>A4 Threshold | STRUCTURE | | | <i>A4-Threshold</i> IE in TS 38.331 Sec 6 | +| 365 | 9>CHOICE A4 Threshold Type | STRUCTURE | | | <i>MeasTriggerQuantity</i> IE in TS 38.331 Sec 6 | +| 366 | 10>A4 Threshold RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | <i>RSRP-Range</i> IE | +| 367 | 10>A4 Threshold RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | <i>RSRQ-Range</i> IE | +| 368 | 10>A4 Threshold SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | <i>SINR-Range</i> IE | +| 369 | 9>A4 Report On Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 370 | 9>A4 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 371 | 9>A4 Time to Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 372 | 9>Use White Cell List | ELEMENT | FALSE | <i>useWhiteCellList</i> IE in TS 38.331 Sec 6 | | +| 375 | 7>Event A5 | STRUCTURE | | | <i>eventA5</i> IE in TS 38.331 Sec 6 | +| 376 | 8>A5 Threshold 1 | STRUCTURE | | | <i>a5-Threshold1</i> IE in TS 38.331 Sec 6 | +| 377 | 9>CHOICE A5 Threshold1 Type | STRUCTURE | | | <i>MeasTriggerQuantity</i> IE in TS 38.331 Sec 6 | +| 378 | 10>A5 Threshold1 RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | <i>RSRP-Range</i> IE | +| 379 | 10>A5 Threshold1 RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | <i>RSRQ-Range</i> IE | +| 380 | 10>A5 Threshold1 SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | <i>SINR-Range</i> IE | +| 381 | 9>CHOICE A5 Threshold2 Type | STRUCTURE | | | <i>a5-Threshold2</i> IE in TS 38.331 Sec 6 | +| 382 | 10>A5 Threshold2 RSRP | ELEMENT | FALSE | <i>MeasTriggerQuantity</i> IE in TS 38.331 | | + +| | | | | | | +|-----|-----------------------------|-----------|-------|-----------------------------------------------|--------------------------------------------------------| +| | | | | Sec 6 | | +| 379 | 10>A5 Threshold2 RSRQ | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | <i>RSRP-Range</i> IE | +| 380 | 10>A5 Threshold2 SINR | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | <i>RSRQ-Range</i> IE | +| 381 | 9>A5 Report On Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 382 | 9>A5 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 383 | 9>A5 Time to Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 384 | 9>Use White Cell List | ELEMENT | FALSE | <i>useWhiteCellList</i> IE in TS 38.331 Sec 6 | | +| 391 | 7>Event A6 | STRUCTURE | | | <i>eventA6</i> IE in TS 38.331 Sec 6 | +| 392 | 8>A6 Threshold | STRUCTURE | | | <i>A6-Threshold</i> IE in TS 38.331 Sec 6 | +| 393 | 9>CHOICE A6 Threshold Type | STRUCTURE | | | <i>MeasTriggerQuantityOffset</i> IE in TS 38.331 Sec 6 | +| 394 | 10>A6 Threshold RSRP Offset | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 395 | 10>A6 Threshold RSRQ Offset | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | +| 396 | 10>A6 Threshold SINR Offset | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | +| 397 | 9>A6 Report On Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 398 | 9>A6 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 399 | 9>A6 Time to Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 400 | 9>Use White Cell List | ELEMENT | FALSE | <i>useWhiteCellList</i> IE in TS 38.331 Sec 6 | | +| 405 | 5>Report CGI | STRUCTURE | | | <i>ReportCGI</i> IE in TS 38.331 Sec 6 | +| 406 | 6>Cell to Report CGI | ELEMENT | TRUE | <i>PhysCellId</i> IE in TS 38.331 Sec 6 | | +| 411 | 5>Report SFTD – NR | STRUCTURE | | | <i>ReportSFTD-NR</i> IE in TS 38.331 Sec 6 | +| 412 | 6>Report SFTD – Measurement | ELEMENT | FALSE | <i>reportSFTD-Meas</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|-----|------------------------------------------|-----------|-------|---------------------------------------------------|-------------------------------------------------------------| +| 413 | 6>Report RSRP | ELEMENT | FALSE | <i>reportRSRP</i> IE in TS 38.331 Sec 6 | | +| 414 | 6>Report SFTD Neigh Meas | ELEMENT | FALSE | <i>reportSFTD-NeighMeas</i> IE in TS 38.331 Sec 6 | | +| 415 | 6>DRX SFTD Neigh Meas | ELEMENT | FALSE | <i>drx-SFTD-NeighMeas</i> IE in TS 38.331 Sec 6 | | +| 416 | 6>List of cells for which to report SFTD | LIST | | | <i>cellsForWhichToReportSFTD</i> IE in TS 38.331 Sec 6 | +| 417 | 7>Cell Item for reporting SFTD | STRUCTURE | | | | +| 418 | 8>Physical Cell Identity | ELEMENT | TRUE | <i>PhyCellId</i> IE in TS 38.331 Sec 6 | | +| 421 | 3>Report Config Inter RAT | STRUCTURE | | | <i>ReportConfigInterRAT</i> IE in TS 38.331 Sec 6 | +| 422 | 4>CHOICE <i>Report Type</i> | STRUCTURE | | | <i>reportType</i> IE in TS 38.331 Sec 6 | +| 423 | 5>Periodical Report Config Inter RAT | STRUCTURE | | | <i>PeriodicalReportConfigInterRAT</i> IE in TS 38.331 Sec 6 | +| 431 | 6>Periodical Inter-RAT Report Interval | ELEMENT | FALSE | <i>reportInterval</i> IE in TS 38.331 Sec 6 | | +| 432 | 6>Periodical Inter-RAT Report Amount | ELEMENT | FALSE | <i>reportAmount</i> IE in TS 38.331 Sec 6 | | +| 435 | 6>Periodical Inter-RAT Report Quantity | STRUCTURE | | | <i>reportQuantity</i> IE in TS 38.331 Sec 6 | +| 436 | 7>Inter-RAT RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 437 | 7>Inter-RAT RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | +| 438 | 7>Inter-RAT SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | +| 439 | 6>Maximum number of cells for reporting | ELEMENT | FALSE | <i>maxReportCells</i> IE in TS 38.331 Sec 6 | | +| 441 | 5>Event Trigger Config Inter RAT | STRUCTURE | | | <i>EventTriggerConfigInterRAT</i> IE in TS 38.331 Sec 6 | +| 442 | 6>CHOICE <i>Event ID</i> | STRUCTURE | | | <i>eventId</i> IE in TS 38.331 Sec 6 | +| 451 | 7>Event B1 | STRUCTURE | | | <i>eventB1</i> IE in TS 38.331 Sec 6 | +| 452 | 8>B1 Threshold EUTRA | STRUCTURE | | | <i>b1-ThresholdEUTRA</i> IE in TS 38.331 Sec 6 | +| 453 | 9>E-UTRA RSRP | ELEMENT | FALSE | <i>RSRP-RangeEUTRA</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|-----|-----------------------------------|-----------|-------|----------------------------------------------|-------------------------------------------------| +| 454 | 9>E-UTRA RSRQ | ELEMENT | FALSE | <i>RSRQ-RangeEUTRA</i> IE in TS 38.331 Sec 6 | | +| 455 | 9>E-UTRA SINR | ELEMENT | FALSE | <i>SINR-RangeEUTRA</i> IE in TS 38.331 Sec 6 | | +| 456 | 8>Event B1 Report On Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 457 | 8>E-UTRA Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 458 | 8>E-UTRA Time To Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 471 | 7>Event B2 | STRUCTURE | | | <i>eventB2</i> IE in TS 38.331 Sec 6 | +| 472 | 8>B2 Threshold1 NR | STRUCTURE | | | <i>b2-Threshold1</i> IE in TS 38.331 Sec 6 | +| 475 | 9>B2 Threshold1 NR RSRP | ELEMENT | FALSE | <i>RSRP-Range</i> IE in TS 38.331 Sec 6 | | +| 476 | 9>B2 Threshold1 NR RSRQ | ELEMENT | FALSE | <i>RSRQ-Range</i> IE in TS 38.331 Sec 6 | | +| 477 | 9>B2 Threshold1 NR SINR | ELEMENT | FALSE | <i>SINR-Range</i> IE in TS 38.331 Sec 6 | | +| 481 | 8>B2 Threshold2 E-UTRA | STRUCTURE | | | <i>b2-Threshold2EUTRA</i> IE in TS 38.331 Sec 6 | +| 482 | 9>B2 Threshold2 E-UTRA RSRP | ELEMENT | FALSE | <i>RSRP-RangeEUTRA</i> IE in TS 38.331 Sec 6 | | +| 483 | 9>B2 Threshold2 E-UTRA RSRQ | ELEMENT | FALSE | <i>RSRQ-RangeEUTRA</i> IE in TS 38.331 Sec 6 | | +| 484 | 9>B2 Threshold2 E-UTRA SINR | ELEMENT | FALSE | <i>SINR-RangeEUTRA</i> IE in TS 38.331 Sec 6 | | +| 491 | 6>Inter-RAT Reference Signal Type | ELEMENT | FALSE | <i>rsType</i> IE in TS 38.331 Sec 6 | | +| 492 | 6>Inter-RAT Report Interval | ELEMENT | FALSE | <i>reportInterval</i> IE in TS 38.331 Sec 6 | | +| 493 | 6>Inter-RAT Report Amount | ELEMENT | FALSE | <i>reportAmount</i> IE in TS 38.331 Sec 6 | | +| 501 | 6>Inter-RAT Report Quantity | STRUCTURE | | | <i>reportQuantity</i> IE in TS 38.331 Sec 6 | +| 502 | 7>Inter-RAT Report Quantity RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 503 | 7>Inter-RAT Report Quantity RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|-----|------------------------------------------------------|-----------|-------|-----------------------------------------------------|----------------------------------------------------| +| 504 | 7>Inter-RAT Report Quantity SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | +| 510 | 6>Maximum number of cells to be reported | ELEMENT | FALSE | <i>maxReportCells</i> IE in TS 38.331 Sec 6 | | +| 519 | <i>CHOICE</i> NR SpCell RSRP Measurement Controlling | STRUCTURE | | | <i>s-MeasureConfig</i> IE in TS 38.331 Sec 6 | +| 520 | 1>SSB RSRP | ELEMENT | FALSE | <i>ssb-RSRP</i> IE in TS 38.331 Sec 6 | | +| 521 | 1>CSI RSRP | ELEMENT | FALSE | <i>csi-RSRP</i> IE in TS 38.331 Sec 6 | | +| 525 | Quantity Config | STRUCTURE | | | <i>QuantityConfig</i> IE in TS 38.331 Sec 6 | +| 526 | 1>Quantity Config NR List | LIST | | | <i>quantityConfigNR-List</i> IE in TS 38.331 Sec 6 | +| 527 | 2>Quantity Config NR | STRUCTURE | | | <i>quantityConfigNR</i> IE in TS 38.331 Sec 6 | +| 528 | 3>Quantity Config NR Cell | STRUCTURE | | | <i>quantityConfigCell</i> IE in TS 38.331 Sec 6 | +| 529 | 4>SSB Filter Config | STRUCTURE | | | <i>ssb-FilterConfig</i> IE in TS 38.331 Sec 6 | +| 530 | 5>SSB Filter Coefficient RSRP | ELEMENT | FALSE | <i>filterCoefficientRSRP</i> IE in TS 38.331 Sec 6 | | +| 531 | 5>SSB Filter Coefficient RSRQ | ELEMENT | FALSE | <i>filterCoefficientRSRQ</i> IE in TS 38.331 Sec 6 | | +| 532 | 5>SSB Filter Coefficient RS-SINR | ELEMENT | FALSE | <i>filterCoefficientRSINR</i> IE in TS 38.331 Sec 6 | | +| 533 | 4>CSI RS Filter Config | STRUCTURE | | | <i>csi-RS-FilterConfig</i> IE in TS 38.331 Sec 6 | +| 534 | 5>CSI RS Filter Coefficient RSRP | ELEMENT | FALSE | <i>filterCoefficientRSRP</i> IE in TS 38.331 Sec 6 | | +| 535 | 5>CSI RS Filter Coefficient RSRQ | ELEMENT | FALSE | <i>filterCoefficientRSRQ</i> IE in TS 38.331 Sec 6 | | +| 536 | 5>CSI RS Filter Coefficient RS-SINR | ELEMENT | FALSE | <i>filterCoefficientRSINR</i> IE in TS 38.331 Sec 6 | | +| 541 | 1>Quantity Config E-UTRA | STRUCTURE | | | <i>quantityConfigEUTRA</i> IE in TS 38.331 Sec 6 | +| 542 | 2>E-UTRA Filter Coefficient RSRP | ELEMENT | FALSE | <i>filterCoefficientRSRP</i> IE in TS 38.331 | | + +| | | | | | | +|-----|-----------------------------------------|-----------|-------|----------------------------------------------------|---------------------------------------------------| +| | | | | Sec 6 | | +| 543 | 2>E-UTRA Filter Coefficient RSRQ | ELEMENT | FALSE | <i>filterCoefficientRSRQ</i> IE in TS 38.331 Sec 6 | | +| 544 | 2>E-UTRA Filter Coefficient RS-SINR | ELEMENT | FALSE | <i>filterCoefficientSINR</i> IE in TS 38.331 Sec 6 | | +| 551 | Measurement Gap Config | STRUCTURE | | | <i>MeasGapConfig</i> IE in TS 38.331 Sec 6 | +| 552 | 1>Gap FR2 for setup | STRUCTURE | | | <i>gapFR2</i> IE in TS 38.331 Sec 6 | +| 553 | 2>FR2 Gap Offset | ELEMENT | FALSE | <i>gapOffset</i> IE in TS 38.331 Sec 6 | | +| 554 | 2>FR2 Measurement Gap Length | ELEMENT | FALSE | <i>mgI</i> IE in TS 38.331 Sec 6 | | +| 555 | 2>FR2 Measurement Gap Repetition Period | ELEMENT | FALSE | <i>mgrp</i> IE in TS 38.331 Sec 6 | | +| 556 | 2>FR2 Measurement Gap Timing Analysis | ELEMENT | FALSE | <i>mgta</i> IE in TS 38.331 Sec 6 | | +| 557 | 2>FR2 Reference Serving Cell Indicator | ELEMENT | TRUE | <i>refServCellIndicator</i> IE in TS 38.331 Sec 6 | | +| 560 | 1>Gap FR1 for setup | STRUCTURE | | | <i>gapFR1</i> IE in TS 38.331 Sec 6 | +| 561 | 2>FR1 Gap Offset | ELEMENT | FALSE | <i>gapOffset</i> IE in TS 38.331 Sec 6 | | +| 562 | 2>FR1 Measurement Gap Length | ELEMENT | FALSE | <i>mgI</i> IE in TS 38.331 Sec 6 | | +| 563 | 2>FR1 Measurement Gap Repetition Period | ELEMENT | FALSE | <i>mgrp</i> IE in TS 38.331 Sec 6 | | +| 564 | 2>FR1 Measurement Gap Timing Analysis | ELEMENT | FALSE | <i>mgta</i> IE in TS 38.331 Sec 6 | | +| 565 | 2>FR1 Reference Serving Cell Indicator | ELEMENT | TRUE | <i>refServCellIndicator</i> IE in TS 38.331 Sec 6 | | +| 570 | 1>Gap UE for setup | STRUCTURE | | | <i>gapUE</i> IE in TS 38.331 Sec 6 | +| 571 | 2>UE Gap Offset | ELEMENT | FALSE | <i>gapOffset</i> IE in TS 38.331 Sec 6 | | +| 572 | 2>UE Measurement Gap Length | ELEMENT | FALSE | <i>mgI</i> IE in TS 38.331 Sec 6 | | +| 573 | 2>UE Measurement Gap Reptition Period | ELEMENT | FALSE | <i>mgrp</i> IE in TS 38.331 Sec 6 | | +| 574 | 2>UE Measurement Gap Timing Analysis | ELEMENT | FALSE | <i>mgta</i> IE in TS 38.331 Sec 6 | | +| 575 | 2>UE Reference Serving Cell Indicator | ELEMENT | TRUE | <i>refServCellIndicator</i> IE in TS 38.331 Sec 6 | | +| 581 | Measurement Gap Sharing Config | STRUCTURE | | | <i>MeasGapSharingConfig</i> IE in TS 38.331 Sec 6 | +| 582 | 1>Gap Sharing FR2 for setup | ELEMENT | FALSE | <i>gapFR2</i> IE in TS 38.331 | | + +| | | | | | | +|-----|-----------------------------|---------|-------|----------------------------------------|--| +| | | | | Sec 6 | | +| 583 | 1>Gap Sharing FR1 for setup | ELEMENT | FALSE | <i>gapFR1</i> IE in TS 38.331<br>Sec 6 | | +| 584 | 1>Gap Sharing UE for setup | ELEMENT | FALSE | <i>gapUE</i> IE in TS 38.331<br>Sec 6 | | + +#### 8.4.10.2 Modify MR Configuration + +Upon receiving the *RIC Control Request* message with the *Measurement Report Configuration Control* Service Style and the *Modify MR Configuration* control action, the E2 node shall invoke RRC procedures related to MR Configuration, include the IEs corresponding to one or more of parameters described below in the related NI interface messages or RRC message. + +In the case of UE group-based control action, the above RRC procedure(s) is invoked individually for each individual UE within the group. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------------------------------------------|--------------------------|----------|-------------------------------------------------|----------------------------------------------------------------------------------------------------------------| +| 1 | List of Measurement Objects to modify or add for modification | LIST | | | <i>measObjectToAddModList</i> IE in TS 38.331 Sec 6 | +| 2 | 1>Measurement Object to modify or add for modification Item | STRUCTURE | | | <i>MeasObjectToAddMod</i> IE in TS 38.331 Sec 6 | +| 3 | 2>Measurement Object ID | ELEMENT | TRUE | <i>MeasObjectID</i> IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the measurement object for the UE via <i>RRCReconfiguration</i> message | +| 4 | 2>CHOICE <i>MO Type</i> | STRUCTURE | | | <i>measObject</i> IE in TS 38.331 Sec 6 | +| 11 | 3> <i>NR MO</i> | STRUCTURE | | | <i>MeasObjectNR</i> IE in TS 38.331 Sec 6 | +| 12 | 4>SSB Frequency | ELEMENT | TRUE | <i>ARFCN-ValueNR</i> IE in TS 38.331 Sec 6 | | +| 13 | 4>SSB Subcarrier spacing | ELEMENT | FALSE | <i>Subcarrier Spacing</i> IE in TS 38.331 Sec 6 | | +| 14 | 4>SSB Primary MTC | STRUCTURE | | | <i>smtc1</i> IE in TS 38.331 Sec 6 | +| 15 | 5>CHOICE <i>Periodicity and Offset</i> | STRUCTURE | | | <i>periodicityAndOffset</i> IE in TS 38.331 Sec 6 | +| 16 | 6>Sub-frame 5 | ELEMENT | FALSE | <i>sf5</i> IE in TS 38.331 Sec 6 | | +| 17 | 6>Sub-frame 10 | ELEMENT | FALSE | <i>sf10</i> IE in TS 38.331 Sec 6 | | +| 18 | 6>Sub-frame 20 | ELEMENT | FALSE | <i>sf20</i> IE in TS 38.331 Sec 6 | | +| 19 | 6>Sub-frame 40 | ELEMENT | FALSE | <i>sf40</i> IE in TS 38.331 Sec 6 | | +| 20 | 6>Sub-frame 80 | ELEMENT | FALSE | <i>sf80</i> IE in TS 38.331 Sec 6 | | +| 21 | 6>Sub-frame 160 | ELEMENT | FALSE | <i>sf160</i> IE in TS 38.331 Sec 6 | | +| 22 | 5>Duration | ELEMENT | FALSE | <i>duration</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|----|-----------------------------------|-----------|-------|------------------------------------------------------|----------------------------------------------------| +| 31 | 4>SSB Secondary MTC | STRUCTURE | | | <i>smtc2</i> IE in TS 38.331 Sec 6 | +| 32 | 5>List of cells | LIST | | | <i>pci-List</i> IE in TS 38.331 Sec 6 | +| 33 | 6>Cell Item | STRUCTURE | | | <i>PhysCellID</i> IE in TS 38.331 Sec 6 | +| 34 | 7>PCI | ELEMENT | TRUE | <i>physCellID</i> IE in TS 38.331 Sec 6 | | +| 35 | 5>Periodicity | ELEMENT | FALSE | <i>periodicity</i> IE in TS 38.331 Sec 6 | | +| 36 | 4>Reference Frequency CSI – RS | ELEMENT | TRUE | <i>refFreqCSI-RS</i> IE in TS 38.331 Sec 6 | | +| 37 | 4>Reference Signal Config | STRUCTURE | | | <i>referenceSignalConfig</i> IE in TS 38.331 Sec 6 | +| 38 | 5>SSB Configuration Mobility | STRUCTURE | | | <i>SSB-ConfigMobility</i> IE in TS 38.331 Sec 6 | +| 39 | 6>Setup or Release SSB to Measure | ELEMENT | FALSE | ENUMERATED (setup,release,...) | <i>SetupRelease</i> IE in TS 38.331 Sec 6 | +| 40 | 6>CHOICE SSB To Measure for setup | STRUCTURE | | | <i>SSB-ToMeasure</i> IE in TS 38.331 Sec 6 | +| 41 | 7>Short Bitmap | ELEMENT | FALSE | <i>shortBitmap</i> IE in TS 38.331 Sec 6 | | +| 42 | 7>Medium Bitmap | ELEMENT | FALSE | <i>mediumBitmap</i> IE in TS 38.331 Sec 6 | | +| 43 | 7>Long Bitmap | ELEMENT | FALSE | <i>longBitmap</i> IE in TS 38.331 Sec 6 | | +| 44 | 6>Derive SSB Index From Cell | ELEMENT | FALSE | <i>deriveSSB-IndexFromCell</i> IE in TS 38.331 Sec 6 | | +| 45 | 6>SS RSSI Measurement | STRUCTURE | | | <i>ss-RSSI-Measurement</i> IE in TS 38.331 Sec 6 | +| 46 | 7>Measurement Slots | ELEMENT | FALSE | <i>measurementSlots</i> IE in TS 38.331 Sec 6 | | +| 47 | 7>End Symbol | ELEMENT | FALSE | <i>endSymbol</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|----|----------------------------------------------------|-----------|-------|------------------------------------------------|------------------------------------------------------------| +| 49 | 6>Setup or Release CSI RS Resource Config Mobility | ELEMENT | FALSE | ENUMERATED (setup, release,...) | <i>SetupRelease</i> IE in TS 38.331 Sec 6 | +| 50 | 6>CSI RS Resource Config Mobility for Setup | STRUCTURE | | | <i>csi-rs-ResourceConfigMobility</i> IE in TS 38.331 Sec 6 | +| 51 | 7>Reference Serving cell Index | ELEMENT | TRUE | <i>refServCellIndex</i> IE in TS 38.331 Sec 6 | | +| 52 | 7>Sub carrier spacing | ELEMENT | FALSE | <i>subcarrierSpacing</i> IE in TS 38.331 Sec 6 | | +| 53 | 7>CSI RS Cell List Mobility | LIST | | | <i>csi-RS-CellList-Mobility</i> IE in TS 38.331 Sec 6 | +| 54 | 8>CSI RS Cell Mobility | STRUCTURE | | | <i>CSI-RS-CellMobility</i> IE in TS 38.331 Sec 6 | +| 55 | 9>Physical Cell ID | ELEMENT | TRUE | <i>PhysCellID</i> IE in TS 38.331 Sec 6 | | +| 56 | 9>CSI RS Measurement Bandwidth | STRUCTURE | | | <i>csi-rs-MeasurementBW</i> IE in TS 38.331 Sec 6 | +| 57 | 10>Number of PRBs | ELEMENT | FALSE | <i>nrofPRBs</i> IE in TS 38.331 Sec 6 | | +| 58 | 10>Start PRB | ELEMENT | FALSE | <i>startPRB</i> IE in TS 38.331 Sec 6 | | +| 59 | 9>Density | ELEMENT | FALSE | <i>Density</i> IE in TS 38.331 Sec 6 | | +| 60 | 9>CSI RS Resource List Mobility | LIST | | | <i>csi-rs-ResourceList-Mobility</i> IE in TS 38.331 Sec 6 | +| 61 | 10>CSI RS Resource Item Mobility | STRUCTURE | | | <i>CSI-RS-Resource-Mobility</i> IE in TS 38.331 Sec 6 | +| 62 | 11>CSI RS Index | ELEMENT | TRUE | <i>csi-RS-Index</i> IE in TS 38.331 Sec 6 | | +| 63 | 11>CHOICE Slot Config | STRUCTURE | | | <i>slotConfig</i> IE in TS 38.331 Sec 6 | +| 64 | 12>ms 4 | ELEMENT | FALSE | <i>ms4</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|----|--------------------------------------------------------------|-----------|-------|--------------------------------------------------------------------|-----------------------------------------------------------------------------| +| 65 | 12>ms<br>5 | ELEMENT | FALSE | <i>ms5</i> IE in TS 38.331 Sec 6 | | +| 66 | 12>ms<br>10 | ELEMENT | FALSE | <i>ms10</i> IE in TS 38.331 Sec 6 | | +| 67 | 12>ms<br>20 | ELEMENT | FALSE | <i>ms20</i> IE in TS 38.331 Sec 6 | | +| 68 | 12>ms<br>40 | ELEMENT | FALSE | <i>ms40</i> IE in TS 38.331 Sec 6 | | +| 69 | 11>Associ<br>ated SSB | STRUCTURE | | | <i>associatedSSB</i> IE in TS 38.331 Sec 6 | +| 70 | 12>SS<br>B Index | ELEMENT | TRUE | <i>ssb-Index</i> IE in TS 38.331 Sec 6 | | +| 71 | 12>Is<br>Quasi<br>colocol<br>o | ELEMENT | FALSE | <i>isQuasiCol<br/>located</i> IE in TS 38.331 Sec 6 | | +| 72 | 11>CHOI<br>CE<br><i>Frequenc<br/>y Domain<br/>Allocation</i> | STRUCTURE | | | <i>frequencyDo<br/>mainnAllocati<br/>on</i> IE in TS 38.331 Sec 6 | +| 73 | 12>Fr<br>equen<br>cy Domai<br>n Allocat<br>ion Row 1 | ELEMENT | FALSE | <i>row1</i> IE in TS 38.331 Sec 6 | | +| 74 | 12>Fr<br>equen<br>cy Domai<br>n Allocat<br>ion Row 2 | ELEMENT | FALSE | <i>row2</i> IE in TS 38.331 Sec 6 | | +| 75 | 11>First<br>OFDM<br>Symbol in<br>Time Domain | ELEMENT | FALSE | <i>firstOFDM<br/>SymbolInTi<br/>meDomain</i> IE in TS 38.331 Sec 6 | | +| 76 | 11>Seque<br>nce Generatio<br>n Config | ELEMENT | FALSE | <i>sequenecG<br/>enerationC<br/>onfig</i> IE in TS 38.331 Sec 6 | | +| 77 | 4>Absolute Threshold SSB –<br>Block Consolidation | STRUCTURE | | | <i>absThreshSS<br/>-<br/>BlocksConsol<br/>idation</i> IE in TS 38.331 Sec 6 | +| 78 | 5>Block Consolidation<br>Threshold RSRP | ELEMENT | FALSE | <i>RSRP-<br/>Range</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|-----|-------------------------------------------|-----------|-------|------------------------------------------------------------|------------------------------------------------------------| +| 79 | 5>Block Consolidation Threshold RSRQ | ELEMENT | FALSE | <i>RSRQ-Range</i> IE in TS 38.331 Sec 6 | | +| 80 | 5>Block Consolidation Threshold SINR | ELEMENT | FALSE | <i>SINR-Range</i> IE in TS 38.331 Sec 6 | | +| 81 | 4>Absolute Threshold CSI RS Consolidation | STRUCTURE | | | <i>absThreshCSI-RS-Consolidation</i> IE in TS 38.331 Sec 6 | +| 82 | 5>RS Consolidation Threshold RSRP | ELEMENT | FALSE | <i>RSRP-Range</i> IE in TS 38.331 Sec 6 | | +| 83 | 5>RS Consolidation Threshold RSRQ | ELEMENT | FALSE | <i>RSRQ-Range</i> IE in TS 38.331 Sec 6 | | +| 84 | 5>RS Consolidated Threshold SINR | ELEMENT | FALSE | <i>SINR-Range</i> IE in TS 38.331 Sec 6 | | +| 91 | 4>Number of SS blocks to average | ELEMENT | FALSE | <i>nrofSS-BlocksToAverage</i> IE in TS 38.331 Sec 6 | | +| 92 | 4>Number of CSI RS Resources to average | ELEMENT | FALSE | <i>nrofCSI-RS-ResourcesToAverage</i> IE in TS 38.331 Sec 6 | | +| 93 | 4>Quantity Config Index | ELEMENT | TRUE | <i>quantityConfigIndex</i> IE in TS 38.331 Sec 6 | | +| 100 | 4>Q-Offset MO Range Sequence | STRUCTURE | | | <i>offsetMO</i> IE in TS 38.331 Sec 6 | +| 101 | 5>RSRP Offset SSB | ELEMENT | FALSE | <i>rsrpOffsetSSB</i> IE in TS 38.331 Sec 6 | | +| 102 | 5>RSRQ Offset SSB | ELEMENT | FALSE | <i>rsrqOffsetSSB</i> IE in TS 38.331 Sec 6 | | +| 103 | 5>SINR Offset SSB | ELEMENT | FALSE | <i>sinrOffsetSSB</i> IE in TS 38.331 Sec 6 | | +| 104 | 5>RSRP Offset CSI RS | ELEMENT | FALSE | <i>rsrpOffsetCSI-RS</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|-----|-------------------------------------------------------------|-----------|-------|-----------------------------------------------|-----------------------------------------------------| +| 105 | 5>RSRQ Offset CSI RS | ELEMENT | FALSE | <i>rsrqOffsetCSI-RS</i> IE in TS 38.331 Sec 6 | | +| 106 | 5>SINR Offset CSI RS | ELEMENT | FALSE | <i>sinrOffsetCSI-RS</i> IE in TS 38.331 Sec 6 | | +| 107 | 4>Cells to Remove List | LIST | | | <i>cellsToRemoveList</i> IE in TS 38.331 Sec 6 | +| 108 | 5>Cell to Remove Item | STRUCTURE | | | | +| 109 | 6>Cell to Remove - Physical Cell ID | ELEMENT | TRUE | <i>PhysCellID</i> IE in TS 38.331 Sec 6 | | +| 110 | 4>Cells to modify or add for modification List | LIST | | | <i>CellsToAddModList</i> IE in TS 38.331 Sec 6 | +| 111 | 5>Cell to modify or add for modification Item | STRUCTURE | | | <i>CellsToAdd</i> IE in TS 38.331 Sec 6 | +| 112 | 6>Cell to modify or add for modification - Physical Cell ID | ELEMENT | TRUE | <i>PhysCellID</i> IE in TS 38.331 Sec 6 | | +| 113 | 6>Cell Individual Offset | STRUCTURE | | | <i>cellIndividualOffset</i> IE in TS 38.331 Sec 6 | +| 115 | 7>RSRP Offset SSB | ELEMENT | FALSE | <i>rsrpOffsetSSB</i> IE in TS 38.331 Sec 6 | | +| 116 | 7>RSRQ Offset SSB | ELEMENT | FALSE | <i>rsrqOffsetSSB</i> IE in TS 38.331 Sec 6 | | +| 117 | 7>SINR Offset SSB | ELEMENT | FALSE | <i>sinrOffsetSSB</i> IE in TS 38.331 Sec 6 | | +| 118 | 7>RSRP Offset CSI RS | ELEMENT | FALSE | <i>rsrpOffsetCSI-RS</i> IE in TS 38.331 Sec 6 | | +| 119 | 7>RSRQ Offset CSI RS | ELEMENT | FALSE | <i>rsrqOffsetCSI-RS</i> IE in TS 38.331 Sec 6 | | +| 120 | 7>SINR Offset CSI RS | ELEMENT | FALSE | <i>sinrOffsetCSI-RS</i> IE in TS 38.331 Sec 6 | | +| 121 | 4>Black cells to Remove List | LIST | | | <i>blackCellsToRemoveList</i> IE in TS 38.331 Sec 6 | +| 122 | 5>Black cell to Remove Item | STRUCTURE | | | | +| 123 | 6>Black cell to Remove – Physical Cell Range Index | ELEMENT | TRUE | <i>PCI-RangeIndex</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|-----|----------------------------------------------------------------------------|-----------|-------|--------------------------------------------------|-----------------------------------------------------| +| | | | | 6 | | +| 125 | 4>Black cells to modify or add for modification List | LIST | | | <i>blackCellsToAddModList</i> IE in TS 38.331 Sec 6 | +| 126 | 5>Black cell to modify or add for modification Item | STRUCTURE | | | <i>PCI-RangeElement</i> IE in TS 38.331 Sec 6 | +| 127 | 6>Black cell to modify or add for modification – Physical Cell Range Index | ELEMENT | TRUE | <i>PCI-RangeIndex</i> IE in TS 38.331 Sec 6 | | +| 128 | 6>Physical Cell ID - Range | STRUCTURE | | | <i>PCI-Range</i> IE in TS 38.331 Sec 6 | +| 129 | 7>PCI Range Start | ELEMENT | TRUE | <i>PhysCellId</i> IE in TS 38.331 Sec 6 | | +| 130 | 7>PCI Range | ELEMENT | FALSE | <i>range</i> IE in TS 38.331 Sec 6 | | +| 131 | 4>White cells to Remove List | LIST | | | <i>whiteCellsToRemoveList</i> IE in TS 38.331 Sec 6 | +| 132 | 5>White cell to Remove Item | STRUCTURE | | | <i>whiteCellsToRemoveList</i> IE in TS 38.331 Sec 6 | +| 133 | 6>White cell to Remove – Physical Cell Range Index | ELEMENT | TRUE | <i>PCI-RangeIndex</i> IE in TS 38.331 Sec 6 | | +| 135 | 4>White cells to modify or add for modification List | LIST | | | <i>whiteCellsToAddModList</i> IE in TS 38.331 Sec 6 | +| 136 | 5>White cell to modify or add for modification Item | STRUCTURE | | | <i>PCI-RangeElement</i> IE in TS 38.331 Sec 6 | +| 137 | 6>White cell to modify or add for modification – Physical Cell Range Index | ELEMENT | TRUE | <i>PCI-RangeIndex</i> IE in TS 38.331 Sec 6 | | +| 138 | 6>Physical Cell ID - Range | STRUCTURE | | | <i>PCI-Range</i> IE in TS 38.331 Sec 6 | +| 139 | 7>PCI Range Start | ELEMENT | TRUE | <i>physCellId</i> IE in TS 38.331 Sec 6 | | +| 140 | 7>PCI Range | ELEMENT | FALSE | <i>range</i> IE in TS 38.331 Sec 6 | | +| 141 | 4>Frequency Band Indicator NR | ELEMENT | TRUE | <i>freqBandIndicatorNR</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|-----|-------------------------------------------------------------------|-----------|-------|-------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------| +| 142 | 4>Measurement Cycle<br>Secondary cell | ELEMENT | FALSE | <i>measCycle<br/>SCell</i> IE in<br>TS 38.331<br>Sec 6 | | +| 151 | 3>E-UTRA MO | STRUCTURE | | | <i>MeasObjectE<br/>UTRA</i> IE in<br>TS 38.331<br>Sec 6 | +| 152 | 4>E-UTRA Carrier Frequency | ELEMENT | TRUE | <i>carrierFreq</i><br>IE in TS<br>38.331 Sec<br>6 | | +| 153 | 4>E-UTRA Allowed Measurement<br>Bandwidth | ELEMENT | FALSE | <i>allowedMe<br/>asBandwid<br/>th</i> IE in TS<br>38.331 Sec<br>6 | | +| 161 | 4>List of E-UTRA cells to remove | LIST | | | <i>cellsToRemo<br/>veListEUTRA<br/>N</i> IE in TS<br>38.331 Sec 6 | +| 162 | 5>E-UTRA Cell to remove Item | STRUCTURE | | | | +| 164 | 6>E-UTRA PCI to remove | ELEMENT | TRUE | <i>EUTRA-<br/>PhysCellID</i><br>IE in TS<br>38.331 Sec<br>6 | Note that RIC<br>cannot use<br>the Cell Index<br>unless<br>informed by<br>the E2 node,<br>so PCI is<br>used here. | +| 171 | 4>List of E-UTRA cells to modify or<br>add for modification | LIST | | | <i>cellsToAddM<br/>odListEUTRA<br/>N</i> IE in TS<br>38.331 Sec 6 | +| 172 | 5>E-UTRA Cell to modify or<br>add for modification Item | STRUCTURE | | | | +| 173 | 6>E-UTRA Cell to modify or<br>add for modification | STRUCTURE | | | <i>EUTRA-Cell</i><br>IE in TS<br>38.331 Sec 6 | +| 174 | 7>E-UTRA PCI to<br>modify or add for<br>modification | ELEMENT | TRUE | <i>EUTRA-<br/>PhysCellId</i><br>IE in TS<br>38.331 Sec<br>6 | | +| 175 | 7>E-UTRA Cell<br>Individual Offset | ELEMENT | FALSE | <i>cellIndividu<br/>alOffset</i> IE<br>in TS<br>38.331 Sec<br>6 | | +| 181 | 4>List of E-UTRA black cells to<br>remove | LIST | | | <i>blackCellsTo<br/>RemoveListE<br/>UTRAN</i> IE in<br>TS 38.331<br>Sec 6 | +| 182 | 5>E-UTRA black cell to remove<br>Item | STRUCTURE | | | | +| 184 | 6>E-UTRA PCI to remove | ELEMENT | TRUE | <i>EUTRA-<br/>PhysCellId</i><br>IE in TS<br>38.331 Sec<br>6 | | +| 191 | 4>List of E-UTRA black cells to<br>modify or add for modification | LIST | | | <i>blackCellsTo<br/>AddModList</i><br>IE in TS<br>38.331 Sec 6 | + +| | | | | | | +|-----|-----------------------------------------------------------------|-----------|-------|---------------------------------------------------------|------------------------------------------------------------------------------------------------------------------| +| 192 | 5>E-UTRA black cell to modify or add for modification item | STRUCTURE | | | | +| 193 | 6>E-UTRA black cell to modify or add for modification | STRUCTURE | | | <i>EUTRA-BlackCell</i> IE in TS 38.331 Sec 6 | +| 194 | 7>E-UTRA Physical Cell ID Range | STRUCTURE | | | <i>EUTRA-PhysCellIdRange</i> IE in TS 38.331 Sec 6 | +| 195 | 8>E-UTRA PCI Start | ELEMENT | TRUE | <i>EUTRA-PhysCellId</i> IE in TS 38.331 Sec 6 | | +| 196 | 8>E-UTRA PCI Range | ELEMENT | FALSE | <i>range</i> IE in TS 38.331 Sec 6 | | +| 201 | 4>E-UTRA Presence Antenna Port 1 | ELEMENT | FALSE | <i>eutra-PresenceAntennaPort1</i> IE in TS 38.331 Sec 6 | | +| 205 | 4>E-UTRA Q Offset Range | ELEMENT | FALSE | <i>eutra-Q-OffsetRange</i> IE in TS 38.331 Sec 6 | | +| 210 | 4>Wideband RSRQ Measurement | ELEMENT | FALSE | <i>widebandRSRQ-Meas</i> IE in TS 38.331 Sec 6 | | +| 301 | List of Report Config Objects to modify or add for modification | LIST | | | <i>ReportConfigToAddModList</i> IE in TS 38.331 Sec 6 | +| 302 | 1>Report Config Object to modify or add for modification Item | STRUCTURE | | | <i>ReportConfigToAddMod</i> IE in TS 38.331 Sec 6 | +| 303 | 2>Report Config Object ID | ELEMENT | TRUE | <i>ReportConfigID</i> IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the report config object for the UE via <i>RRCReconfiguration</i> message | +| 304 | 2>CHOICE <i>Report Config Type</i> | STRUCTURE | | | <i>reportConfig</i> IE in TS 38.331 Sec 6 | +| 311 | 3> <i>NR Report Config</i> | STRUCTURE | | | <i>ReportConfigNR</i> IE in TS 38.331 Sec 6 | +| 312 | 4>CHOICE <i>Report Type</i> | STRUCTURE | | | <i>reportType</i> IE in TS 38.331 Sec 6 | +| 313 | 5>Periodical Report Config | STRUCTURE | | | <i>PeriodicalReportConfig</i> IE in TS 38.331 Sec 6 | + +| | | | | | | +|-----|-----------------------------------------------------------|-----------|-------|--------------------------------------------------------|-------------------------------------------------------| +| 314 | 6>NR RS Type | ELEMENT | FALSE | <i>NR-RS-Type</i> IE in TS 38.331 Sec 6 | | +| 315 | 6>NR Report Interval | ELEMENT | FALSE | <i>ReportInterval</i> IE in TS 38.331 Sec 6 | | +| 316 | 6>NR Report Amount | ELEMENT | FALSE | <i>reportAmount</i> IE in TS 38.331 Sec 6 | | +| 317 | 6>Measurement Report Quantity | STRUCTURE | | | <i>MeasReportQuantity</i> IE in TS 38.331 Sec 6 | +| 318 | 7>MR RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 319 | 7>MR RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | +| 320 | 7>MR SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | +| 321 | 6>Maximum number of Report cells | ELEMENT | FALSE | <i>maxReportCells</i> IE in TS 38.331 Sec 6 | | +| 322 | 6>Report Quantity Reference Signal – Indexes | STRUCTURE | | | <i>reportQuantityRS-Indexes</i> IE in TS 38.331 Sec 6 | +| 323 | 7>Report Qty RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 324 | 7>Report Qty RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | +| 325 | 7>Report Qty SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | +| 326 | 6>Maximum number of reference signals – Indexes to Report | ELEMENT | FALSE | <i>maxNrofRS-IndexesToReport</i> IE in TS 38.331 Sec 6 | | +| 327 | 6>Include Beam Measurements | ELEMENT | FALSE | <i>includeBeamMeasurements</i> IE in TS 38.331 Sec 6 | | +| 328 | 6>Use WhiteCellList | ELEMENT | FALSE | <i>useWhiteCellList</i> IE in TS 38.331 Sec 6 | | +| 331 | 5>Event Trigger Config | STRUCTURE | | | <i>EventTriggerConfig</i> IE in TS 38.331 Sec 6 | +| 332 | 6>CHOICE <i>Event ID</i> | STRUCTURE | | | <i>eventid</i> IE in TS 38.331 Sec 6 | +| 333 | 7>Event A1 | STRUCTURE | | | <i>eventA1</i> IE in TS 38.331 | + +| | | | | | | +|-----|--------------------------------------|-----------|-------|--------------------------------------------|--------------------------------------------------| +| | | | | | Sec 6 | +| 334 | 8>A1 Threshold | STRUCTURE | | | <i>a1-Threshold</i> IE in TS 38.331 Sec 6 | +| 335 | 9>CHOICE A1<br><i>Threshold Type</i> | STRUCTURE | | | <i>MeasTriggerQuantity</i> IE in TS 38.331 Sec 6 | +| 336 | 10>A1<br>Threshold<br>RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | <i>RSRP-Range</i> IE | +| 337 | 10>A1<br>Threshold<br>RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | <i>RSRQ-Range</i> IE | +| 338 | 10>A1<br>Threshold<br>SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | <i>SINR-Range</i> IE | +| 339 | 9>A1 Report On<br>Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 340 | 9>A1 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 341 | 9>A1 Time to<br>Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 343 | 7>Event A2 | STRUCTURE | | | <i>eventA2</i> IE in TS 38.331 Sec 6 | +| 344 | 8>A2 Threshold | STRUCTURE | | | <i>A2-Threshold</i> IE in TS 38.331 Sec 6 | +| 345 | 9>CHOICE A2<br><i>Threshold Type</i> | STRUCTURE | | | <i>MeasTriggerQuantity</i> IE in TS 38.331 Sec 6 | +| 346 | 10>A2<br>Threshold<br>RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | <i>RSRP-Range</i> IE | +| 347 | 10>A2<br>Threshold<br>RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | <i>RSRQ-Range</i> IE | +| 348 | 10>A2<br>Threshold<br>SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | <i>SINR-Range</i> IE | +| 349 | 9>A2 Report On<br>Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 350 | 9>A2 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 351 | 9>A2 Time to<br>Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 353 | 7>Event A3 | STRUCTURE | | | <i>eventA3</i> IE in TS 38.331 Sec 6 | +| 354 | 8>A3 Offset | STRUCTURE | | | <i>a3-Threshold</i> IE in TS 38.331 Sec 6 | + +| | | | | | | +|-----|-----------------------------------|-----------|-------|-----------------------------------------------|--------------------------------------------------------| +| 355 | 9>CHOICE A3<br>Offset Type | STRUCTURE | | | <i>MeasTriggerQuantityOffset</i> IE in TS 38.331 Sec 6 | +| 356 | 10>A3<br>Threshold<br>RSRP Offset | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 357 | 10>A3<br>Threshold<br>RSRQ Offset | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | +| 358 | 10>A3<br>Threshold<br>SINR Offset | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | +| 359 | 9>A3 Report On<br>Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 360 | 9>A3 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 361 | 9>A3 Time to<br>Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 362 | 9>Use White Cell<br>List | ELEMENT | FALSE | <i>useWhiteCellList</i> IE in TS 38.331 Sec 6 | | +| 363 | 7>Event A4 | STRUCTURE | | | <i>eventA4</i> IE in TS 38.331 Sec 6 | +| 364 | 8>A4 Threshold | STRUCTURE | | | <i>A4-Threshold</i> IE in TS 38.331 Sec 6 | +| 365 | 9>CHOICE A4<br>Threshold Type | STRUCTURE | | | <i>MeasTriggerQuantity</i> IE in TS 38.331 Sec 6 | +| 366 | 10>A4<br>Threshold<br>RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | <i>RSRP-Range</i> IE | +| 367 | 10>A4<br>Threshold<br>RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | <i>RSRQ-Range</i> IE | +| 368 | 10>A4<br>Threshold<br>SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | <i>SINR-Range</i> IE | +| 369 | 9>A4 Report On<br>Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 370 | 9>A4 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 371 | 9>A4 Time to<br>Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 372 | 9>Use White Cell<br>List | ELEMENT | FALSE | <i>useWhiteCellList</i> IE in TS 38.331 Sec 6 | | +| 375 | 7>Event A5 | STRUCTURE | | | <i>eventA5</i> IE in TS 38.331 Sec 6 | + +| | | | | | | +|-----|-----------------------------|-----------|-------|--------------------------------------------------|--------------------------------------------------------| +| 376 | 8>A5 Threshold 1 | STRUCTURE | | | <i>a5-Threshold1</i> IE in TS 38.331 Sec 6 | +| 377 | 9>CHOICE A5 Threshold1 Type | STRUCTURE | | | <i>MeasTriggerQuantity</i> IE in TS 38.331 Sec 6 | +| 378 | 10>A5 Threshold1 RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | <i>RSRP-Range</i> IE | +| 379 | 10>A5 Threshold1 1 RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | <i>RSRQ-Range</i> IE | +| 380 | 10>A5 Threshold1 SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | <i>SINR-Range</i> IE | +| 381 | 9>CHOICE A5 Threshold2 Type | STRUCTURE | | | <i>a5-Threshold2</i> IE in TS 38.331 Sec 6 | +| 382 | 10>A5 Threshold2 RSRP | ELEMENT | FALSE | <i>MeasTriggerQuantity</i> IE in TS 38.331 Sec 6 | | +| 379 | 10>A5 Threshold2 RSRQ | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | <i>RSRP-Range</i> IE | +| 380 | 10>A5 Threshold2 SINR | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | <i>RSRQ-Range</i> IE | +| 381 | 9>A5 Report On Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 382 | 9>A5 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 383 | 9>A5 Time to Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 384 | 9>Use White Cell List | ELEMENT | FALSE | <i>useWhiteCellList</i> IE in TS 38.331 Sec 6 | | +| 391 | 7>Event A6 | STRUCTURE | | | <i>eventA6</i> IE in TS 38.331 Sec 6 | +| 392 | 8>A6 Threshold | STRUCTURE | | | <i>A6-Threshold</i> IE in TS 38.331 Sec 6 | +| 393 | 9>CHOICE A6 Threshold Type | STRUCTURE | | | <i>MeasTriggerQuantityOffset</i> IE in TS 38.331 Sec 6 | +| 394 | 10>A6 Threshold RSRP Offset | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 395 | 10>A6 Threshold RSRQ Offset | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | +| 396 | 10>A6 Threshold SINR Offset | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | + +| | | | | | | +|-----|------------------------------------------|-----------|-------|---------------------------------------------------|-------------------------------------------------------------| +| 397 | 9>A6 Report On Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 398 | 9>A6 Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 399 | 9>A6 Time to Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 400 | 9>Use White Cell List | ELEMENT | FALSE | <i>useWhiteCellList</i> IE in TS 38.331 Sec 6 | | +| 405 | 5>Report CGI | STRUCTURE | | | <i>ReportCGI</i> IE in TS 38.331 Sec 6 | +| 406 | 6>Cell to Report CGI | ELEMENT | TRUE | <i>physCellId</i> IE in TS 38.331 Sec 6 | | +| 411 | 5>Report SFTD – NR | STRUCTURE | | | <i>ReportSFTD-NR</i> IE in TS 38.331 Sec 6 | +| 412 | 6>Report SFTD – Measurement | ELEMENT | FALSE | <i>reportSFTD-Meas</i> IE in TS 38.331 Sec 6 | | +| 413 | 6>Report RSRP | ELEMENT | FALSE | <i>reportRSRP</i> IE in TS 38.331 Sec 6 | | +| 414 | 6>Report SFTD Neigh Meas | ELEMENT | FALSE | <i>reportSFTD-NeighMeas</i> IE in TS 38.331 Sec 6 | | +| 415 | 6>DRX SFTD Neigh Meas | ELEMENT | FALSE | <i>drx-SFTD-NeighMeas</i> IE in TS 38.331 Sec 6 | | +| 416 | 6>List of cells for which to report SFTD | LIST | | | <i>cellsForWhichToReportSFTD</i> IE in TS 38.331 Sec 6 | +| 417 | 7>Cell Item for reporting SFTD | STRUCTURE | | | | +| 418 | 8>Physical Cell Identity | ELEMENT | TRUE | <i>physCellId</i> IE in TS 38.331 Sec 6 | | +| 421 | 3>Report Config Inter RAT | STRUCTURE | | | <i>ReportConfigInterRAT</i> IE in TS 38.331 Sec 6 | +| 422 | 4>CHOICE <i>Report Type</i> | STRUCTURE | | | <i>reportType</i> IE in TS 38.331 Sec 6 | +| 423 | 5>Periodical Report Config Inter RAT | STRUCTURE | | | <i>PeriodicalReportConfigInterRAT</i> IE in TS 38.331 Sec 6 | + +| | | | | | | +|-----|-----------------------------------------|-----------|-------|----------------------------------------------|---------------------------------------------------------| +| 431 | 6>Periodical Inter-RAT Report Interval | ELEMENT | FALSE | <i>reportInterval</i> IE in TS 38.331 Sec 6 | | +| 432 | 6>Periodical Inter-RAT Report Amount | ELEMENT | FALSE | <i>reportAmount</i> IE in TS 38.331 Sec 6 | | +| 435 | 6>Periodical Inter-RAT Report Quantity | STRUCTURE | | | <i>reportQuantity</i> IE in TS 38.331 Sec 6 | +| 436 | 7>Inter-RAT RSRP | ELEMENT | FALSE | <i>rsrp</i> IE in TS 38.331 Sec 6 | | +| 437 | 7>Inter-RAT RSRQ | ELEMENT | FALSE | <i>rsrq</i> IE in TS 38.331 Sec 6 | | +| 438 | 7>Inter-RAT SINR | ELEMENT | FALSE | <i>sinr</i> IE in TS 38.331 Sec 6 | | +| 439 | 6>Maximum number of cells for reporting | ELEMENT | FALSE | <i>maxReportCells</i> IE in TS 38.331 Sec 6 | | +| 441 | 5>Event Trigger Config Inter RAT | STRUCTURE | | | <i>EventTriggerConfigInterRAT</i> IE in TS 38.331 Sec 6 | +| 442 | 6>CHOICE <i>Event ID</i> | STRUCTURE | | | <i>eventId</i> IE in TS 38.331 Sec 6 | +| 451 | 7>Event B1 | STRUCTURE | | | <i>eventB1</i> IE in TS 38.331 Sec 6 | +| 452 | 8>B1 Threshold EUTRA | STRUCTURE | | | <i>b1-ThresholdEUTRA</i> IE in TS 38.331 Sec 6 | +| 453 | 9>E-UTRA RSRP | ELEMENT | FALSE | <i>RSRP-RangeEUTRA</i> IE in TS 38.331 Sec 6 | | +| 454 | 9>E-UTRA RSRQ | ELEMENT | FALSE | <i>RSRQ-RangeEUTRA</i> IE in TS 38.331 Sec 6 | | +| 455 | 9>E-UTRA SINR | ELEMENT | FALSE | <i>SINR-RangeEUTRA</i> IE in TS 38.331 Sec 6 | | +| 456 | 8>Event B1 Report On Leave | ELEMENT | FALSE | <i>reportOnLeave</i> IE in TS 38.331 Sec 6 | | +| 457 | 8>E-UTRA Hysteresis | ELEMENT | FALSE | <i>hysteresis</i> IE in TS 38.331 Sec 6 | | +| 458 | 8>E-UTRA Time To Trigger | ELEMENT | FALSE | <i>timeToTrigger</i> IE in TS 38.331 Sec 6 | | +| 471 | 7>Event B2 | STRUCTURE | | | <i>eventB2</i> IE in TS 38.331 | + +| | | | | | | +|-----|------------------------------------------|-----------|-------|----------------------------------------------|--------------------------------------------------| +| | | | | | Sec 6 | +| 472 | 8>B2 Threshold1 NR | STRUCTURE | | | <i>b2-Threshold1 IE</i> in TS 38.331 Sec 6 | +| 475 | 9>B2 Threshold1 NR RSRP | ELEMENT | FALSE | <i>RSRP-Range IE</i> in TS 38.331 Sec 6 | | +| 476 | 9>B2 Threshold1 NR RSRQ | ELEMENT | FALSE | <i>RSRQ-Range IE</i> in TS 38.331 Sec 6 | | +| 477 | 9>B2 Threshold1 NR SINR | ELEMENT | FALSE | <i>SINR-Range IE</i> in TS 38.331 Sec 6 | | +| 481 | 8>B2 Threshold2 E-UTRA | STRUCTURE | | | <i>b2-Threshold2E-UTRA IE</i> in TS 38.331 Sec 6 | +| 482 | 9>B2 Threshold2 E-UTRA RSRP | ELEMENT | FALSE | <i>RSRP-RangeEUTRA IE</i> in TS 38.331 Sec 6 | | +| 483 | 9>B2 Threshold2 E-UTRA RSRQ | ELEMENT | FALSE | <i>RSRQ-RangeEUTRA IE</i> in TS 38.331 Sec 6 | | +| 484 | 9>B2 Threshold2 E-UTRA SINR | ELEMENT | FALSE | <i>SINR-RangeEUTRA IE</i> in TS 38.331 Sec 6 | | +| 491 | 6>Inter-RAT Reference Signal Type | ELEMENT | FALSE | <i>rsType IE</i> in TS 38.331 Sec 6 | | +| 492 | 6>Inter-RAT Report Interval | ELEMENT | FALSE | <i>reportInterval IE</i> in TS 38.331 Sec 6 | | +| 493 | 6>Inter-RAT Report Amount | ELEMENT | FALSE | <i>reportAmount IE</i> in TS 38.331 Sec 6 | | +| 501 | 6>Inter-RAT Report Quantity | STRUCTURE | | | <i>reportQuantity IE</i> in TS 38.331 Sec 6 | +| 502 | 7>Inter-RAT Report Quantity RSRP | ELEMENT | FALSE | <i>rsrp IE</i> in TS 38.331 Sec 6 | | +| 503 | 7>Inter-RAT Report Quantity RSRQ | ELEMENT | FALSE | <i>rsrq IE</i> in TS 38.331 Sec 6 | | +| 504 | 7>Inter-RAT Report Quantity SINR | ELEMENT | FALSE | <i>sinr IE</i> in TS 38.331 Sec 6 | | +| 510 | 6>Maximum number of cells to be reported | ELEMENT | FALSE | <i>maxReportCells IE</i> in | | + +| | | | | | | +|-----|-----------------------------------------------|-----------|-------|---------------------------------------------|---------------------------------------------| +| | | | | TS 38.331<br>Sec 6 | | +| 519 | CHOICE NR SpCell RSRP Measurement Controlling | STRUCTURE | | | s-MeasureConfig IE in TS 38.331 Sec 6 | +| 520 | 1>SSB RSRP | ELEMENT | FALSE | ssb-RSRP IE in TS 38.331 Sec 6 | | +| 521 | 1>CSI RSRP | ELEMENT | FALSE | csi-RSRP IE in TS 38.331 Sec 6 | | +| 525 | Quantity Config | STRUCTURE | | | QuantityConfig IE in TS 38.331 Sec 6 | +| 526 | 1>Quantity Config NR List | LIST | | | quantityConfigNR-List IE in TS 38.331 Sec 6 | +| 527 | 2>Quantity Config NR | STRUCTURE | | | quantityConfigNR IE in TS 38.331 Sec 6 | +| 528 | 3>Quantity Config NR Cell | STRUCTURE | | | quantityConfigCell IE in TS 38.331 Sec 6 | +| 529 | 4>SSB Filter Config | STRUCTURE | | | ssb-FilterConfig IE in TS 38.331 Sec 6 | +| 530 | 5>SSB Filter Coefficient RSRP | ELEMENT | FALSE | filterCoefficientRSRP IE in TS 38.331 Sec 6 | | +| 531 | 5>SSB Filter Coefficient RSRQ | ELEMENT | FALSE | filterCoefficientRSRQ IE in TS 38.331 Sec 6 | | +| 532 | 5>SSB Filter Coefficient RS-SINR | ELEMENT | FALSE | filterCoefficientSINR IE in TS 38.331 Sec 6 | | +| 533 | 4>CSI RS Filter Config | STRUCTURE | | | csi-RS-FilterConfig IE in TS 38.331 Sec 6 | +| 534 | 5>CSI RS Filter Coefficient RSRP | ELEMENT | FALSE | filterCoefficientRSRP IE in TS 38.331 Sec 6 | | +| 535 | 5>CSI RS Filter Coefficient RSRQ | ELEMENT | FALSE | filterCoefficientRSRQ IE in TS 38.331 Sec 6 | | +| 536 | 5>CSI RS Filter Coefficient RS-SINR | ELEMENT | FALSE | filterCoefficientSINR IE in TS 38.331 Sec 6 | | +| 541 | 1>Quantity Config E-UTRA | STRUCTURE | | | quantityConfigEUTRA IE in | + +| | | | | | | +|-----|--------------------------------------------|-----------|-------|-----------------------------------------------------------------|-----------------------------------------------| +| | | | | | TS 38.331<br>Sec 6 | +| 542 | 2>E-UTRA Filter Coefficient RSRP | ELEMENT | FALSE | <i>filterCoefficientRSRP</i><br>IE in TS<br>38.331 Sec<br>6 | | +| 543 | 2>E-UTRA Filter Coefficient RSRQ | ELEMENT | FALSE | <i>filterCoefficientRSRQ</i><br>IE in TS<br>38.331 Sec<br>6 | | +| 544 | 2>E-UTRA Filter Coefficient RS-SINR | ELEMENT | FALSE | <i>filterCoefficientSINR</i><br>IE in TS<br>38.331 Sec<br>6 | | +| 551 | Measurement Gap Config | STRUCTURE | | | <i>MeasGapConfig</i> IE in TS<br>38.331 Sec 6 | +| 552 | 1>Setup or Release Gap FR2 | ELEMENT | FALSE | ENUMERATED<br>(setup,<br>release,...) | <i>SetupRelease</i> IE in TS<br>38.331 Sec 6 | +| 553 | 1>Gap FR2 to Setup | STRUCTURE | | | <i>gapFR2</i> IE in<br>TS 38.331<br>Sec 6 | +| 554 | 2>FR2 Gap Offset | ELEMENT | FALSE | <i>gapOffset</i><br>IE in TS<br>38.331 Sec<br>6 | | +| 555 | 2>FR2 Measurement Gap Length | ELEMENT | FALSE | <i>mgl</i> IE in<br>TS 38.331<br>Sec 6 | | +| 556 | 2>FR2 Measurement Gap Repetition<br>Period | ELEMENT | FALSE | <i>mgrp</i> IE in<br>TS 38.331<br>Sec 6 | | +| 557 | 2>FR2 Measurement Gap Timing Analysis | ELEMENT | FALSE | <i>mgta</i> IE in<br>TS 38.331<br>Sec 6 | | +| 558 | 2>FR2 Reference Serving Cell Indicator | ELEMENT | TRUE | <i>refServCell<br/>Indicator</i> IE<br>in TS<br>38.331 Sec<br>6 | | +| 560 | 1>Setup or Release Gap FR1 | ELEMENT | FALSE | ENUMERATED<br>(setup,<br>release,...) | <i>SetupRelease</i> IE in TS<br>38.331 Sec 6 | +| 561 | 1>Gap FR1 to Setup | STRUCTURE | | | <i>gapFR1</i> IE in<br>TS 38.331<br>Sec 6 | +| 562 | 2>FR1 Gap Offset | ELEMENT | FALSE | <i>gapOffset</i><br>IE in TS<br>38.331 Sec<br>6 | | +| 563 | 2>FR1 Measurement Gap Length | ELEMENT | FALSE | <i>mgl</i> IE in<br>TS 38.331<br>Sec 6 | | +| 564 | 2>FR1 Measurement Gap Repetition<br>Period | ELEMENT | FALSE | <i>mgrp</i> IE in<br>TS 38.331<br>Sec 6 | | +| 565 | 2>FR1 Measurement Gap Timing Analysis | ELEMENT | FALSE | <i>mgta</i> IE in<br>TS 38.331<br>Sec 6 | | +| 566 | 2>FR1 Reference Serving Cell Indicator | ELEMENT | TRUE | <i>refServCell<br/>Indicator</i> IE | | + +| | | | | | | +|-----|---------------------------------------|-----------|-------|----------------------------------------------------|---------------------------------------------------| +| | | | | <i>in TS 38.331 Sec 6</i> | | +| 570 | 1>Setup or Release Gap UE | ELEMENT | FALSE | ENUMERATED (setup, release,...) | <i>SetupRelease IE in TS 38.331 Sec 6</i> | +| 571 | 1>Gap UE to Setup | STRUCTURE | | | <i>gapUE IE in TS 38.331 Sec 6</i> | +| 572 | 2>UE Gap Offset | ELEMENT | FALSE | <i>gapOffset IE in TS 38.331 Sec 6</i> | | +| 573 | 2>UE Measurement Gap Length | ELEMENT | FALSE | <i>mgI IE in TS 38.331 Sec 6</i> | | +| 574 | 2>UE Measurement Gap Reptition Period | ELEMENT | FALSE | <i>mgrp IE in TS 38.331 Sec 6</i> | | +| 575 | 2>UE Measurement Gap Timing Analysis | ELEMENT | FALSE | <i>mgta IE in TS 38.331 Sec 6</i> | | +| 576 | 2>UE Reference Serving Cell Indicator | ELEMENT | TRUE | <i>refServCell Indicator IE in TS 38.331 Sec 6</i> | | +| 581 | Measurement Gap Sharing Config | STRUCTURE | | | <i>MeasGapSharingConfig IE in TS 38.331 Sec 6</i> | +| 582 | 1>Setup or Release Gap Sharing FR2 | ELEMENT | FALSE | ENUMERATED(setup, release,...) | <i>SetupRelease IE in TS 38.331 Sec 6</i> | +| 583 | 1>Gap Sharing FR2 for setup | ELEMENT | FALSE | <i>gapFR2 IE in TS 38.331 Sec 6</i> | | +| 584 | 1>Setup or Release Gap Sharing FR1 | ELEMENT | FALSE | ENUMERATED (setup, release,...) | <i>SetupRelease IE in TS 38.331 Sec 6</i> | +| 585 | 1>Gap Sharing FR1 for setup | ELEMENT | FALSE | <i>gapFR1 IE in TS 38.331 Sec 6</i> | | +| 586 | 1>Setup or Release Gap Sharing UE | ELEMENT | FALSE | ENUMERATED (setup, release,...) | <i>SetupRelease IE in TS 38.331 Sec 6</i> | +| 587 | 1>Gap Sharing UE | ELEMENT | FALSE | <i>gapUE IE in TS 38.331 Sec 6</i> | | + +### 8.4.10.3 Delete MR Configuration + +Upon receiving the *RIC Control Request* message with the *Measurement Report Configuration Control* Service Style and the *Modify MR Configuration* control action, the E2 node shall invoke RRC procedures related to deletion of MR Configuration and include the IEs corresponding to one or more of parameters described below in the related interface or RRC messages. + +In the case of UE group-based control action, the above RRC procedure(s) is invoked individually for each individual UE within the group. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------|--------------------------|----------|---------------------------------------------|-------------------------------------------------------| +| 1 | List of Measurement Objects to Remove | LIST | | | <i>measObjectToRemoveList</i> IE in TS 38.331 Sec 6 | +| 2 | 1>Measurement Object to Remove Item | STRUCTURE | | | <i>MeasObjectToRemove</i> IE in TS 38.331 Sec 6 | +| 3 | 2>Measurement Object ID | ELEMENT | TRUE | <i>MeasObjectID</i> IE in TS 38.331 Sec 6 | | +| 4 | List of Report Config Objects to Remove | LIST | | | <i>ReportConfigToRemoveList</i> IE in TS 38.331 Sec 6 | +| 5 | 1>Report Config Object to Remove Item | STRUCTURE | | | <i>ReportConfigToRemove</i> IE in TS 38.331 Sec 6 | +| 6 | 2>Report Config Object ID | ELEMENT | TRUE | <i>ReportConfigID</i> IE in TS 38.331 Sec 6 | | +| 7 | List of Measurement IDs to Remove | LIST | | | <i>measIdToRemoveList</i> IE in TS 38.331 Sec 6 | +| 8 | 1>Measurement ID Item to Remove | STRUCTURE | | | | +| 9 | 2>Measurement ID | ELEMENT | TRUE | <i>MeasID</i> IE in TS 38.331 Sec 6 | | + +#### 8.4.10.4 Control Outcome parameters + +In the case of a UE-specific control action, upon processing the above RRC procedure (*RRCReconfiguration* message) with the control action parameters sent by the RIC, the E2 node shall report the call processing outcome to the RIC as a response to the control action based on the following parameters. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------------------------------|--------------------------|----------|--------------------------------|---------------------------------------------------------------------------------------------------------| +| 1 | List of Measurement Objects successfully added | LIST | | 0..1 | <i>MeasObjectToAddModList</i> IE in TS 38.331 Sec 6 | +| 2 | >Measurement Object successfully added Item | STRUCTURE | | 1..<maxMeasObjects> | <i>MeasObjectID</i> IE in TS 38.331 Sec 6 | +| 3 | >>Measurement Object sequence ID | ELEMENT | TRUE | INTEGER (1..maxMeasObject,...) | This is the ID used by the RIC for the measurement object it seeks to add via the control service style | +| 4 | >>Measurement Object ID | ELEMENT | TRUE | <i>MeasObjectID</i> IE in TS | This is the ID used by the E2 node for | + +| | | | | | | +|----|---------------------------------------------------|-----------|-------|-------------------------------------------|----------------------------------------------------------------------------------------------------------------| +| | | | | 38.331 Sec 6 | the measurement object for the UE via <i>RRCReconfiguration</i> message | +| 11 | List of Measurement Objects failed to be added | LIST | | <i>0..1</i> | <i>MeasObjectToAddModList</i> IE in TS 38.331 Sec 6 | +| 12 | >Measurement Object failed to be added Item | STRUCTURE | | <i>1..<maxMeasObjects></i> | <i>MeasObjectId</i> IE in TS 38.331 Sec 6 | +| 14 | >>Measurement Object sequence ID | ELEMENT | TRUE | INTEGER (1..maxMeasObject,...) | This is the ID used by the RIC for the measurement object it seeks to add via the control service style | +| 15 | >>Addition failure cause | ELEMENT | FALSE | PrintableString(SIZE(1..150, ...)) | Failure cause string | +| 21 | List of Measurement Objects successfully modified | LIST | | <i>0..1</i> | <i>MeasObjectToAddModList</i> IE in TS 38.331 Sec 6 | +| 22 | >Measurement Object successfully modified Item | STRUCTURE | | <i>1..<maxMeasObjects></i> | <i>MeasObjectId</i> IE in TS 38.331 Sec 6 | +| 24 | >>Measurement Object ID | ELEMENT | TRUE | <i>MeasObjectID</i> IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the measurement object for the UE via <i>RRCReconfiguration</i> message | +| 31 | List of Measurement Objects failed to be modified | LIST | | <i>0..1</i> | <i>MeasObjectToAddModList</i> IE in TS 38.331 Sec 6 | +| 32 | >Measurement Object failed to be modified Item | STRUCTURE | | <i>1..<maxMeasObjects></i> | <i>MeasObjectId</i> IE in TS 38.331 Sec 6 | +| 34 | >>Measurement Object ID | ELEMENT | TRUE | <i>MeasObjectID</i> IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the measurement object for the UE via <i>RRCReconfiguration</i> | + +| | | | | | | +|----|--------------------------------------------------|-----------|-------|-------------------------------------------|----------------------------------------------------------------------------------------------------------------| +| | | | | | message | +| 35 | >>Modification Failure Cause | ELEMENT | FALSE | PrintableString(SIZE(1..150, ...)) | Failure cause string | +| 41 | List of Measurement Objects successfully deleted | LIST | | 0..1 | <i>MeasObjectToRemoveList</i> IE in TS 38.331 Sec 6 | +| 42 | >Measurement Object successfully deleted Item | STRUCTURE | | 1..<maxMeasObjects> | <i>MeasObjectID</i> IE in TS 38.331 Sec 6 | +| 44 | >>Measurement Object ID | ELEMENT | TRUE | <i>MeasObjectID</i> IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the measurement object for the UE via <i>RRCReconfiguration</i> message | +| 51 | List of Measurement Objects failed to be deleted | LIST | | 0..1 | <i>MeasObjectToRemoveList</i> IE in TS 38.331 Sec 6 | +| 52 | >Measurement Object failed to be deleted Item | STRUCTURE | | 1..<maxMeasObjects> | <i>MeasObjectID</i> IE in TS 38.331 Sec 6 | +| 54 | >>Measurement Object ID | ELEMENT | TRUE | <i>MeasObjectID</i> IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the measurement object for the UE via <i>RRCReconfiguration</i> message | +| 55 | >>Delete Failure Cause | ELEMENT | FALSE | PrintableString(SIZE(1..150, ...)) | Failure cause string | +| 61 | List of Report Config Objects successfully added | LIST | | 0..1 | <i>ReportConfigToAddModList</i> IE in TS 38.331 Sec 6 | +| 62 | >Report Config Object successfully added Item | STRUCTURE | | 1..<maxReportConfigObjects> | <i>maxReportConfigID</i> IE in TS 38.331 Sec 6 | +| 63 | >>Report Config Object sequence ID | ELEMENT | TRUE | INTEGER (1..maxReportConfigObjects,...) | This is the ID used by the RIC for the report config object it seeks to add via the control service style | + +| | | | | | | +|----|-----------------------------------------------------|-----------|-------|---------------------------------------------|------------------------------------------------------------------------------------------------------------------| +| 64 | >>Report Config Object ID | ELEMENT | TRUE | <i>ReportConfigID</i> IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the report config object for the UE via <i>RRCReconfiguration</i> message | +| 71 | List of Report Config Objects failed to be added | LIST | | <i>0..1</i> | <i>ReportConfigToAddModList</i> IE in TS 38.331 Sec 6 | +| 72 | >Report Config Object failed to be added Item | STRUCTURE | | <i>1..<maxReportConfigObjects></i> | <i>maxReportConfigID</i> IE in TS 38.331 Sec 6 | +| 74 | >>Report Config Object sequence ID | ELEMENT | TRUE | INTEGER (1..maxReportConfigObjects,...) | This is the ID used by the RIC for the report config object it attempts to add via the control service style | +| 75 | >>Addition failure cause | ELEMENT | FALSE | PrintableString(SIZE(1..150, ...)) | Failure cause string | +| 81 | List of Report Config Objects successfully modified | LIST | | <i>0..1</i> | <i>ReportConfigToAddModList</i> IE in TS 38.331 Sec 6 | +| 82 | >Report Config Object successfully modified Item | STRUCTURE | | <i>1..<maxReportConfigObjects></i> | <i>maxReportConfigID</i> IE in TS 38.331 Sec 6 | +| 84 | >>Report Config Object ID | ELEMENT | TRUE | <i>ReportConfigID</i> IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the report config object for the UE via <i>RRCReconfiguration</i> message | +| 91 | List of Report Config Objects failed to be modified | LIST | | <i>0..1</i> | <i>ReportConfigToAddModList</i> IE in TS 38.331 Sec 6 | +| 92 | >Report Config Object failed to be modified Item | STRUCTURE | | <i>1..<maxReportConfigObjects></i> | <i>maxReportConfigID</i> IE in TS 38.331 Sec 6 | +| 94 | >>Report Config Object ID | ELEMENT | TRUE | <i>ReportConfigID</i> IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the report config object for the UE via <i>RRCReconfiguration</i> message | + +| | | | | | | +|-----|----------------------------------------------------|-----------|-------|--------------------------------------|-----------------------------------------------------------------------------------------------------------| +| | | | | | uration<br>message | +| 95 | >>Modification Failure Cause | ELEMENT | FALSE | PrintableString(SIZE(1..150, ...)) | Failure cause string | +| 101 | List of Report Config Objects successfully deleted | LIST | | 0..1 | ReportConfigToRemoveList IE in TS 38.331 Sec 6 | +| 102 | >Report Config Object successfully deleted Item | STRUCTURE | | 1..<maxReportConfigObjects> | maxReportConfigId IE in TS 38.331 Sec 6 | +| 104 | >>Report Config Object ID | ELEMENT | TRUE | ReportConfigId IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the report config object for the UE via RRCReconfiguration message | +| 111 | List of Report Config Objects failed to be deleted | LIST | | 0..1 | ReportConfigToRemoveList IE in TS 38.331 Sec 6 | +| 112 | >Report Config Object failed to be deleted Item | STRUCTURE | | 1..<maxReportConfigObjects> | maxReportConfigId IE in TS 38.331 Sec 6 | +| 114 | >>Report Config Object ID | ELEMENT | TRUE | ReportConfigId IE in TS 38.331 Sec 6 | This is the ID used by the E2 node for the report config object for the UE via RRCReconfiguration message | +| 115 | >>Delete Failure Cause | ELEMENT | FALSE | PrintableString(SIZE(1..150, ...)) | Failure cause string | +| 116 | List of Measurement IDs successfully added | LIST | | 0..1 | MeasIdToAddModList IE in TS 38.331 Sec 6 | +| 117 | >Measurement ID successfully added Item | STRUCTURE | | 1..<maxMeasId> | maxNrofMeasId IE in TS 38.331 Sec 6 | +| 118 | >>Measurement ID | ELEMENT | TRUE | MeasId IE in TS 38.331 Sec 6 | | +| 119 | >>Measurement Object ID | ELEMENT | TRUE | MeasObjectID IE in TS 38.331 Sec 6 | | +| 120 | >>Report Config Object ID | ELEMENT | TRUE | ReportConfigId IE in TS | | + +| | | | | | | +|-----|----------------------------------------------|-----------|-------|-------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | 38.331 Sec 6 | | +| 125 | List of Measurement IDs successfully removed | LIST | | 0..1 | <i>measIdToRemoveList</i> IE in TS 38.331 Sec 6 | +| 126 | >Measurement ID successfully removed Item | STRUCTURE | | 1..<maxMeasID> | <i>maxNrofMeasId</i> IE in TS 38.331 Sec 6 | +| 127 | >>Measurement ID | ELEMENT | TRUE | <i>MeasId</i> IE in TS 38.331 Sec 6 | | +| 129 | List of Measurement IDs failed to be removed | LIST | | 0..1 | <i>measIdToRemoveList</i> IE in TS 38.331 Sec 6 | +| 130 | >Measurement ID failed to be removed Item | STRUCTURE | | 1..<maxMeasID> | <i>maxNrofMeasId</i> IE in TS 38.331 Sec 6 | +| 131 | >>Measurement ID | ELEMENT | TRUE | <i>MeasId</i> IE in TS 38.331 Sec 6 | | +| 132 | >>Removal failure Cause | ELEMENT | FALSE | PrintableString(SIZE(1..150, ...)) | Failure cause string | +| 135 | Received Timestamp | ELEMENT | FALSE | OCTET STRING (SIZE(8)) | Time RIC Control Request message received by RAN Function over E2 interface.<br><br>Carries UTC time encoded as the 64-bit timestamp format as defined in Clause 6 of IETF RFC 5905 [30] containing both seconds and fraction parts. | + +| Range bound | Explanation | +|------------------------|-----------------------------------------------------------------------------------------------| +| maxMeasObjects | Maximum no. of measurement objects supported by the RAN function. The value is <64>. | +| maxReportConfigObjects | Maximum no. of report configuration objects supported by the RAN function. The value is <64>. | +| maxMeasID | Maximum no. of measurement IDs supported by the RAN function. The value is <64> | + +## 8.4.11 Beamforming Configuration Control + +### 8.4.11.1 Non-GoB BF Mode Configuration + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------|--------------------------|----------|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | MIMO Mode Index | ELEMENT | TRUE | INTEGER (1..2, ...) | Value = 1 means the SU (single-user) MIMO mode. Value 2 means the MU (multi-user) MIMO mode. | +| 2 | Non-GoB Beamforming Mode Index | ELEMENT | FALSE | INTEGER (0.. 65535, ...) | The index is used for Non- Grid of Beams (Non-GoB) beamforming optimization for 5G mMIMO deployments [32]. Each BF mode implies a vendor-specific proprietary Non-GoB BF algorithm that are not standardized [33], for which each E2 Node, who supports the Non-GoB beamforming optimization feature, provides the number of different Non-GoB BF mode(s) supported by its scheduler indexed from 1 to n. The AI/ML model for Non-GoB beamforming optimization is trained by data and measurements related to each BF mode and/or MIMO mode, for which the trained AI/ML model, based on collected data, configures the E2 Node with the best inferred Non-GoB BF mode index to be used for each UE, where such configuration could be done separately for the case of Single User- and/or Multi-user MIMO [32]. The Value = 0 means release of Non-GoB BF mode for the UE of subject. | + +Upon receiving the *RIC Control Request* message, the E2 node shall invoke procedures related to configuring the Non-GoB MIMO beamforming mode index of the UE given by the value of the *Non-GoB Beamforming Mode Index* IE, possibly based on the MIMO mode chosen for the UE by the scheduler by the *MIMO Mode Index* IE. The recommended value of the Non-GoB beamforming mode index for the UE by the Near-RT RIC, along with the + +corresponding MIMO mode index given by the *MIMO Mode Index* IE if configured, is saved by the E2 node. If and when the MAC scheduler configures the UE and in the MIMO mode indicated by the *MIMO Mode Index* IE if configured, then the scheduler shall use the *Non-GoB Beamforming Mode Index* IE recommended by the Near-RT RIC (that is saved in the E2 node). + +## 8.4.11.2 GoB BF Configuration + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------|--------------------------|----------|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | RI-LI-PMI config | STRUCTURE | TRUE | | Precoding Matrix Indicator (PMI), Rank Indicator (RI), Layer Indicator (LI) in TS 38.214 [36] Clause 5.2.2.2. The AI/ML model for CSI-RS and DMRS optimization infers the best PMI, RI, LI to be used for each UE [32]. | +| 2 | > RI | ELEMENT | TRUE | INTEGER (0,...,8) | RI in TS 38.214 [36] Clause 5.2.2.2. The value=0 means RI-PMI reporting is not supported for the UE of interest. | +| 3 | > LI | ELEMENT | TRUE | INTEGER (0,...,8) | LI in TS 38.214 [36] Clause 5.2.2.2. The value=0 means LI-reporting is not supported for the UE of interest. | +| 4 | > i1 | STRUCTURE | TRUE | | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 5 | >> i11 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 6 | >> i12 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 7 | >> i13 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 8 | >> i131 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 9 | >> i132 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 10 | >> i14 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 11 | >> i141 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 12 | >> i142 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 13 | >> i143 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 14 | >> i15 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 15 | >> i161 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 16 | >> i162 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | + +| | | | | | | +|----|---------|-----------|------|---------------------|----------------------------------------------------| +| 17 | >> i171 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 18 | >> i172 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 19 | >> i173 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 20 | >> i174 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 21 | >> i181 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 22 | >> i182 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 23 | >> i183 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 24 | >> i184 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 25 | > i2 | STRUCTURE | TRUE | | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 26 | >> i20 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 27 | >> i21 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 28 | >> i211 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 29 | >> i212 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 30 | >> i22 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 31 | >> i221 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 32 | >> i222 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 33 | >> i231 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 34 | >> i232 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 35 | >> i233 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 36 | >> i234 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 37 | >> i241 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 38 | >> i242 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 39 | >> i243 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS | + +| | | | | | | +|----|-----------------|---------|------|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | | 38.214 [36] Clause 5.2.2.2. | +| 40 | >> i244 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 41 | >> i251 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 42 | >> i252 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 43 | >> i253 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 44 | >> i254 | ELEMENT | TRUE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 45 | > Subband Index | ELEMENT | TRUE | INTEGER (0,...,19) | Subband index for PMI reporting in TS 38.214 [36] Clause 5.2.1.4. The value=0 means Subband PMI reporting is not supported for the UE of interest. | +| 46 | P-2 Beam Index | ELEMENT | TRUE | INTEGER (0,...,256) | P-2 beam index in TS 38.912 [37] Clause 8.2.1.6.1. The AI/ML model for CSI-RS and DMRS optimization infers the best P-2 beam index to be used for each UE [32]. The value=0 means P-2-beam management is not supported for the UE of interest. | + +Upon receiving the RIC Control Request message, the E2 node shall invoke procedures related to configuring the GoB MIMO beamforming configuration of the UE given by the value of the RI-LI-PMI config or the P-2 Beam Index IE. In order to generate the precoding matrix from the values in RI-LI-PMI config, the E2 node shall combine the values in RI, i1 and i2 with the Codebook configuration parameters (e.g., Type I, Type II etc.) as described in TS 38.214 [36] Clause 5.2.2.2. The recommended value of the GoB beamforming configuration for the UE by the Near-RT RIC is saved by the E2 node. When the MAC scheduler configures the UE, the scheduler shall use the RI-LI-PMI config or the P-2 Beam Index IE recommended by the Near-RT RIC (that is saved in the E2 node). + +## 8.5 RAN parameters for POLICY services + +### 8.5.1 Approach + +The RAN parameters associated with each policy action being controlled by Near-RT RIC described in Clause 7.7 are listed. + +There are two types of E2 policies: + +- Control action policy:** In this type, the Near-RT RIC tells the E2 node on the specific per-UE control action that needs to be performed, upon meeting a given policy condition for a given UE or a group of UEs, for a given cell and/or for a given E2 node. This policy type is descriptive in nature. The control action is defined with respect to individual UEs and UE-specific bearers, flows, PDU sessions, etc. +- Offset based policy:** In this type, the Near-RT RIC offers a generic prescriptive guidance to the E2 node on how it shall deviate from default behavior via the application of offset parameters provided in the *Policy Action* IE. + +Different *Policy Action* IEs are associated with different *Policy Condition ID* IEs and *Policy Condition* IEs are described in terms of UE and E2 Node characteristics. As defined in Clause 6.6.3, offset parameters are to be applied to default parameters according to the following rules: + +- INTEGER and REAL default parameters: Offset parameter have the same data type as default parameter and is added to default parameter with positive offset parameter values increasing default value and negative offset parameter values decreasing default value. That is, policy modifies the target call process such that: +Value to be applied = (Default Parameter) + (Offset Parameter) +- ENUMERATED parameters: Offset parameter are of data type INTEGER and are used to select a different item in the ENUMERATED list, positive offset parameter values used to select items that are further on in the list, zero offset parameter values used to select the default value, negative offset parameter values used to select items that are earlier on in the list. When and if the offset parameter value results in the selection of an item in the ENUMERATED list that exceeds the ENUMERATED list length then the last item in the list is selected. When and if the offset parameter value results in the selection of an item in the ENUMERATED list that prior to the first item in the ENUMERATED list then the first item in the list is selected. That is, policy modifies the target call process such that: +ENUMERATED List index = MIN [List length-1, MAX [0, (Default Parameter) + (Offset Parameter)]] + +## 8.5.1A Common RAN Parameters for POLICY services + +The common set of RAN Parameters that can be used across all POLICY service styles is given in the table below. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------------------------------------|---------------------------------------------------------------------|----------|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 5001 | Measurement Object | ELEMENT | FALSE | ENUMERATED (UE, E2 Node,...) | If the value is <i>UE</i> , then the rest of the ensuing parameters related to PMs have UE-specific values for the UE ID. Else if the value is E2 Node, then the rest of the parameters shall have node-specific measurements | +| 5002 | gNB DU Measurements | STRUCTURE | | | | +| | >UE Throughput Measurements | Refer to <b>gNB DU Measurements</b> structure in Clause 8.1.1.14 | | | | +| | >Packet level measurements | | | | | +| | >Packet delay measurements | | | | | +| 5011 | gNB CU-UP Measurements | STRUCTURE | | | | +| | >PDCP data volume measurement | Refer to <b>gNB CU-UP Measurements</b> structure in Clause 8.1.1.13 | | | | +| | >Packet delay measurements | | | | | +| 5021 | gNB CU-CP Measurements | STRUCTURE | | | | +| | >Inter-gNB handovers | Refer to <b>gNB CU-CP Measurements</b> structure in Clause 8.1.1.12 | | | | +| | >Intra-gNB handovers | | | | | +| | >RRC connection related measurements | | | | | +| | >QoS flow-related measurements | | | | | +| | >DRB related measurements | | | | | +| | >PDU Session Management | | | | | +| | >Inter-system mobility measurements between 5GS and EPS | | | | | + +In addition to using the above RAN Parameters, POLICY conditions may also use RAN parameters defined in Clause 8.1 for *RIC Event Trigger Definition* IE. + +## 8.5.2 Radio Bearer Policy + +### 8.5.2.0 Common RAN Parameters for Radio Bearer Policy + +The RAN Parameters pertaining to POLICY Conditions for the “Radio Bearer Control” policy service style used across all POLICY actions of the policy service style are listed in the below table. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------------------------------|----------------------------------------------------------------------------------------------------------------|----------|----------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------| +| 501 | DRB related measurements | <b>Refer to <i>gNB CU-CP Measurements</i> structure in Clause 8.1.1.12 where these parameters are defined.</b> | | | | +| 502 | List of QoS levels | | | | | +| 503 | >QoS level item | | | | | +| 504 | >>CHOICE QoS level | | | | | +| 505 | >>>5QI | | | | | +| 506 | >>>S-NSSAI | | | | | +| 507 | >>>>SST | | | | | +| 508 | >>>>SD | | | | | +| 509 | >>Number of DRBs successfully setup per QoS level | | | | | +| 510 | Total number of DRBs successfully setup for UE | ELEMENT | FALSE | INTEGER (0..64) | Total number of DRBs across all QoS levels for a UE. Maximum 64 DRBs can be setup for a UE. Refer to TS 38.473 [19] Clause 9.2.2.1 | +| 511 | UE DL Aggregate Maximum Bit Rate | ELEMENT | FALSE | <i>UE Aggregate Maximum Bit Rate Downlink</i> IE in TS 36.423 [17] clause 9.2.12 | | +| 512 | gNB CU-UP capacity | <b>Refer to <i>E2 Node</i> structure in Clause 8.1.1.11 where these parameters are defined</b> | | | | + +In addition to using the above RAN Parameters for POLICY conditions, this service style also uses RAN parameters defined in Clause 8.1. Accordingly, this service style supports Policy Conditions using the RAN parameters defined in Clauses 8.1, 8.5.1 and those covered in the above table. + +## 8.5.2.1 DRB QoS Configuration + +### 8.5.2.1.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.2.1. + +### 8.5.2.1.2 Offset + +**Editor's Note: FFS** + +## 8.5.2.2 QoS flow mapping configuration + +### 8.5.2.2.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.2.2. + +### 8.5.2.2.2 Offset + +**Editor's Note: FFS** + +## 8.5.2.3 Logical channel configuration + +### 8.5.2.3.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.2.3. + +#### 8.5.2.3.2 Offset + +Editor's Note: FFS + +#### 8.5.2.4 Radio Bearer Admission Control + +##### 8.5.2.4.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.2.4. + +##### 8.5.2.4.2 Offset + +#### 8.5.2.5 DRB Termination Control + +##### 8.5.2.5.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.2.5. + +##### 8.5.2.5.2 Offset + +Editor's Note: FFS + +#### 8.5.2.6 DRB Split Ratio Control + +##### 8.5.2.6.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.2.6. + +##### 8.5.2.6.2 Offset + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------|--------------------------|----------|--------------------------|---------------------------------------------------------------------| +| 101 | Uplink PDCP Data Split Threshold offset | ELEMENT | FALSE | INTEGER | <i>UL Data Split Threshold</i> IE in TS 37.483 [21] Clause 9.3.1.43 | +| 102 | Downlink PDCP Data Split | ELEMENT | FALSE | INTEGER | <i>Downlink PDCP Data Split</i> IE in 8.4.2.6 | + +#### 8.5.2.7 PDCP Duplication Control + +##### 8.5.2.7.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.2.7. + +##### 8.5.2.7.2 Offset + +Editor's Note: FFS + +### 8.5.3 Radio Resource Allocation Policy + +#### 8.5.3.0 Common RAN Parameters for Radio Resource Allocation Policy + +The RAN Parameters pertaining to POLICY Conditions for the “Radio Resource Allocation Control” policy service style used across all POLICY actions of the policy service style are listed in the below table. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------------|--------------------------|----------|---------------------------------------------------------|-----------------------------------------------------| +| 501 | SPS Config | STRUCTURE | | | <i>SPS-Config</i> IE in TS 38.331 [22] | +| 502 | >Number of HARQ Processes | ELEMENT | FALSE | <i>nrofHARQ-Processes</i> IE in TS 38.331 [22] | | +| 503 | Grant Configuration | STRUCTURE | | | <i>ConfiguredGrantConfig</i> IE in TS 38.331 [22] | +| 504 | >Number of HARQ Processes | ELEMENT | FALSE | <i>nrofHARQ-Processes</i> IE in TS 38.331 [22] | | +| 505 | PDSCH Serving Cell Config Setup | STRUCTURE | | | <i>PDSCH-ServingCellConfig</i> IE in TS 38.331 [22] | +| 506 | >Number of HARQ Processes | ELEMENT | FALSE | <i>nrofHARQ-ProcessesForPD SCH</i> IE in TS 38.331 [22] | | + +In addition to using the above RAN Parameters for Policy conditions, this service style also uses RAN parameters defined in Clause 8.1. Accordingly, this service style supports Policy Conditions using the RAN parameters defined in Clauses 8.1, 8.5.1 and those covered in the above table. + +### 8.5.3.1 DRX Parameter Configuration + +#### 8.5.3.1.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.3.1. + +#### 8.5.3.1.2 Offset + +**Editor's Note: FFS** + +### 8.5.3.2 Scheduling Request Parameter Configuration + +#### 8.5.3.2.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.3.2. + +#### 8.5.3.2.2 Offset + +**Editor's Note: FFS** + +### 8.5.3.3 Semi-Persistent Scheduling Parameter Configuration + +#### 8.5.3.3.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.3.3. + +#### 8.5.3.3.2 Offset + +**Editor's Note: FFS** + +### 8.5.3.4 Configured Grant Configuration + +#### 8.5.3.4.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.3.4. + +#### 8.5.3.4.2 Offset + +**Editor's Note: FFS** + +### 8.5.3.5 CQI table configuration + +#### 8.5.3.5.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.3.5. + +#### 8.5.3.5.2 Offset + +**Editor's Note: FFS** + +### 8.5.3.6 Slice-level PRB quota + +#### 8.5.3.6.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.3.6. + +#### 8.5.3.6.2 Offset + +**Editor's Note: FFS** + +## 8.5.4 Connected Mode Mobility Policy + +### 8.5.4.0 Common RAN Parameters for Connected Mode Mobility Policy + +The RAN Parameters pertaining to POLICY Conditions for the “Connected Mode Mobility Control” policy service style used across all POLICY actions of the policy service style are listed in the below table. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key flag | RAN Parameter Definition | +|------------------|-----------------------------------|--------------------------|----------|----------------------------------------------------------------------------------------------| +| 501 | List of Serving Cells | LIST | | Refer to <i>Handover Preparation</i> structure in 8.1.2.3.1 where this parameter is defined. | +| 502 | >Serving Cell Item | STRUCTURE | | Refer to <i>Handover Preparation</i> structure in 8.1.2.3.1 where this parameter is defined. | +| 503 | >>CHOICE <i>Cell Type</i> | STRUCTURE | | Refer to <i>Handover Preparation</i> structure in 8.1.2.3.1 where this parameter is defined. | +| 504 | >>>NR Cell | STRUCTURE | | Refer to <i>Handover Preparation</i> structure in 8.1.2.3.1 where this parameter is defined | +| 505 | >>>>NR CGI | ELEMENT | TRUE | Refer to <i>NR Cell</i> structure in 8.1.1.1 where this parameter is defined | +| 506 | >>>>NR PCI | ELEMENT | FALSE | Refer to <i>NR Cell</i> structure in 8.1.1.1 where this parameter is defined | +| 507 | >>>>PLMN Identity | ELEMENT | FALSE | Refer to <i>NR Cell</i> structure in 8.1.1.1 where this parameter is defined | +| 508 | >>>>Reported NR RRC Measurements | STRUCTURE | | Refer to <i>Reported NR RRC Measurements</i> in 8.1.1.1 where this parameter is defined | +| 509 | >>>>>Cell Results | STRUCTURE | | Refer to <i>Cell Results</i> structure in 8.1.1.1 where this parameter is defined | +| 510 | >>>>>>SSB Results | STRUCTURE | | Refer to <i>SSB Results</i> structure in 8.1.1.1 where this parameter is defined | +| 511 | >>>>>>CSI-RS Results | STRUCTURE | | Refer to <i>CSI-RS Results</i> structure in 8.1.1.1 where this parameter is defined | +| 512 | >>>E-UTRA Cell | STRUCTURE | | Refer to <i>E-UTRA Cell</i> structure in 8.1.1.2 where this parameter is defined | +| 513 | >>>>ECGI | ELEMENT | TRUE | Refer to <i>E-UTRA Cell</i> structure in 8.1.1.2 where this parameter is defined | +| 514 | >>>>PCI | ELEMENT | FALSE | Refer to <i>E-UTRA Cell</i> structure in 8.1.1.2 where this parameter is defined | +| 515 | >>>>PLMN Identity | ELEMENT | FALSE | Refer to <i>E-UTRA Cell</i> structure in 8.1.1.2 where this parameter is defined | +| 516 | >>>>Reported LTE RRC Measurements | STRUCTURE | | Refer to <i>Reported LTE RRC Measurements</i> in 8.1.1.2 where this parameter is defined | +| 521 | List of Neighbouring Cells | LIST | | Refer to <i>Handover Preparation</i> structure in 8.1.2.3.1 where this parameter is defined. | +| 522 | >Neighbouring Cell Item | STRUCTURE | | Refer to <i>Handover Preparation</i> structure in 8.1.2.3.1 where this parameter is defined. | +| 523 | >>CHOICE <i>Cell Type</i> | STRUCTURE | | Refer to <i>Handover Preparation</i> structure in 8.1.2.3.1 where this parameter is defined. | +| 524 | >>>NR Cell | STRUCTURE | | Refer to <i>NR Cell</i> structure in 8.1.1.12 where this parameter is defined | +| 525 | >>>>NR CGI | ELEMENT | TRUE | Refer to <i>NR Cell</i> structure in 8.1.1.12 where this parameter is defined | +| 526 | >>>>NR PCI | ELEMENT | FALSE | Refer to <i>NR Cell</i> structure in 8.1.1.12 where this parameter is defined | +| 527 | >>>>PLMN Identity | ELEMENT | FALSE | Refer to <i>NR Cell</i> structure in 8.1.1.12 where this parameter is defined | +| 528 | >>>>Reported NR RRC Measurements | STRUCTURE | | Refer to <i>Reported NR RRC Measurements</i> in 8.1.1.1 where this parameter is defined | +| 529 | >>>>>Cell Results | STRUCTURE | | Refer to <i>Cell Results</i> structure in 8.1.1.1 where this parameter is defined | +| 530 | >>>>>>SSB Results | STRUCTURE | | Refer to <i>SSB Results</i> structure in 8.1.1.1 where this parameter is defined | +| 531 | >>>>>>CSI-RS Results | STRUCTURE | | Refer to <i>CSI-RS Results</i> structure in 8.1.1.1 where this parameter is defined | +| 532 | >>>E-UTRA Cell | STRUCTURE | | Refer to <i>E-UTRA Cell</i> structure in 8.1.1.2 where this parameter is defined | +| 533 | >>>>ECGI | STRUCTURE | | Refer to <i>E-UTRA Cell</i> structure in 8.1.1.2 where this parameter is defined | +| 534 | >>>>PCI | STRUCTURE | | Refer to <i>E-UTRA Cell</i> structure in 8.1.1.2 where this parameter is defined | + +| | | | | | +|-----|-------------------------------------------|-----------|-------|------------------------------------------------------------------------------------------------------------------------------| +| 535 | >>>>PLMN Identity | ELEMENT | FALSE | Refer to <i>E-UTRA Cell</i> structure in 8.1.1.11 where this parameter is defined | +| 536 | >>>>Reported LTE RRC Measurements | STRUCTURE | | Refer to <i>Reported LTE RRC Measurements</i> in 8.1.1.2 where this parameter is defined | +| 541 | gNB Handover measurements | STRUCTURE | | | +| 542 | >Inter-gNB handover measurements | STRUCTURE | | Refer to <i>Inter-gNB Handovers</i> structure in 8.1.1.12 where this parameter is defined | +| 543 | >Intra-gNB handover measurements | STRUCTURE | | Refer to <i>Intra-gNB Handovers</i> structure in 8.1.1.12 where this parameter is defined | +| 544 | >Inter-system mobility measurements | STRUCTURE | | Refer to <i>Inter-system mobility measurements between 5GS and EPS</i> structure in 8.1.1.12 where this parameter is defined | +| 545 | NR Composite Available Capacity Group | STRUCTURE | | Refer to <i>Composite Available Capacity Group</i> in 8.1.1.1 where this parameter is defined | +| 546 | E-UTRA Composite Available Capacity Group | STRUCTURE | | Refer to <i>Composite Available Capacity Group</i> in 8.1.1.2 where this parameter is defined | + +In addition to using the above RAN Parameters for Policy conditions, this service style also uses RAN parameters defined in Clause 8.1. Accordingly, this service style supports Policy Conditions using the RAN parameters defined in Clauses 8.1, 8.5.1 and those covered in the above table. + +## 8.5.4.1 Handover Control + +### 8.5.4.1.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.4.1. + +### 8.5.4.1.2 Offset + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|---------------------------|--------------------------|----------|--------------------------|-----------------------------------------------------------------------------------------------------| +| 101 | A1 Event Threshold offset | STRUCTURE | | | <i>EventA1</i> IE in 8.1.1.10 | +| 102 | >RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, i.e. RSRP threshold to be used is default RSRP+RSRP Offset | +| 103 | >RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, i.e. RSRP threshold to be used is default RSRQ+RSRQ Offset | +| 104 | >SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, i.e. RSRP threshold to be used is default SINR+SINR Offset | +| 105 | >Hysteresis | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 111 | A2 Event Threshold offset | STRUCTURE | | | <i>EventA2</i> IE in 8.1.1.10 | +| 112 | >RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 113 | >RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 114 | >SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 115 | >Hysteresis | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 121 | A3 Event Threshold offset | STRUCTURE | | | <i>EventA3</i> IE in 8.1.1.10 | +| 122 | >RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 123 | >RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 124 | >SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 125 | >Hysteresis | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 131 | A4 Event Threshold offset | STRUCTURE | | | <i>EventA4</i> IE in 8.1.1.10 | +| 132 | >RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 133 | >RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 134 | >SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 135 | >Hysteresis | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 140 | A5 Event Threshold offset | STRUCTURE | | | <i>EventA5</i> IE in 8.1.1.10 | +| 141 | >A5-Threshold1 offset | STRUCTURE | | | <i>EventA5</i> IE in 8.1.1.10 | +| 142 | >>RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 143 | >>RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 144 | >>SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 145 | >>Hysteresis | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 146 | >A5-Threshold2 offset | STRUCTURE | | | <i>EventA5</i> IE in 8.1.1.10 | +| 147 | >>RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 148 | >>RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to | + +| | | | | | | +|-----|----------------------------|-----------|-------|---------|------------------------------------------| +| | | | | | default values, | +| 149 | >>SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 150 | >>Hysteresis Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 151 | A6 Event Threshold Offset | STRUCTURE | | | <i>EventA6</i> IE in 8.1.1.10 | +| 152 | >RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 153 | >RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 154 | >SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 155 | >Hysteresis Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 161 | B1 Event Threshold Offset | STRUCTURE | | | <i>EventB1</i> IE in 8.1.1.10 | +| 162 | >RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 163 | >RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 164 | >SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 165 | >Hysteresis Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 170 | B2 Event Threshold offset | STRUCTURE | | | <i>EventB2</i> IE in 8.1.1.10 | +| 171 | >B2-Threshold-NR offset | STRUCTURE | | | <i>EventB2</i> IE in 8.1.1.10 | +| 172 | >>RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 173 | >>RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 174 | >>SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 175 | >>Hysteresis Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 176 | >B2-Threshold-EUTRA offset | STRUCTURE | | | <i>EventB2</i> IE in 8.1.1.10 | +| 177 | >>RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 178 | >>RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 179 | >>SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 180 | >>Hysteresis Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | + +## 8.5.4.2 Conditional Handover Control + +### 8.5.4.2.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.4.2. + +### 8.5.4.2.2 Offset + +The RAN parameters associated with this policy type are listed in the table in Clause 8.5.4.1.2. + +### 8.5.4.3 DAPS Handover Control + +#### 8.5.4.3.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.4.3. + +#### 8.5.4.3.2 Offset + +The RAN parameters associated with this policy type are listed in the table in Clause 8.5.4.1.2. + +## 8.5.5 Radio Access Policy + +### 8.5.5.0 Common RAN Parameters for Radio Access Policy + +The RAN Parameters pertaining to POLICY Conditions for the “Radio Access Control” policy service style used across all POLICY actions of the policy service style are listed in the below table. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key flag | Parameter description | +|------------------|-----------------------------------------|--------------------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 501 | E2 Node | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 | +| 502 | >CHOICE E2 Node Component Type | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 503 | >>NG-RAN gNB DU | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 504 | >>>gNB DU Measurements | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 505 | >>>List of NR cells | LIST | | Refer to <i>gNB DU Measurements</i> structure in 8.1.1.14 where this parameter is defined | +| 506 | >>>>NR Cell Item | STRUCTURE | | Refer to <i>gNB DU Measurements</i> structure in 8.1.1.14 where this parameter is defined | +| 507 | >>>>>Radio Resource Utilization | STRUCTURE | | Refer to <i>Radio Resource Utilization</i> structure in 8.1.1.14 where this parameter is defined. This has load measurements in terms of PRB usage. | +| 508 | >>>>>Number of active UE measurements | STRUCTURE | | Refer to <i>Number of active UE measurements</i> structure in 8.1.1.14 where this parameter is defined. This has load measurements in terms of number of active UEs. | +| 509 | >>>>>Slice Available Capacity List | STRUCTURE | | Refer to <i>Slice Available Capacity List</i> in 8.1.1.1 | +| 511 | >>NG-RAN gNB CU-CP | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 512 | >>>RRC connection related measurements | STRUCTURE | | Refer to <i>gNB CU-CP Measurements</i> structure in 8.1.1.12 where this parameter is defined | +| 521 | >>NG-RAN gNB | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 522 | >>>gNB DU Measurements | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 523 | >>>List of NR cells | LIST | | Refer to <i>gNB DU Measurements</i> structure in 8.1.1.14 where this parameter is defined | +| 524 | >>>>NR Cell Item | STRUCTURE | | Refer to <i>gNB DU Measurements</i> structure in 8.1.1.14 where this parameter is defined | +| 525 | >>>>>Radio Resource Utilization | STRUCTURE | | Refer to <i>Radio Resource Utilization</i> structure in 8.1.1.14 where this parameter is defined. This has load measurements in terms of PRB usage. | +| 526 | >>>>>Number of active UE measurements | STRUCTURE | | Refer to <i>Number of active UE measurements</i> structure in 8.1.1.14 where this parameter is defined. This has load measurements in terms of number of active UEs. | +| 527 | >>>>>Slice Available Capacity List | STRUCTURE | | Refer to <i>Slice Available Capacity List</i> in 8.1.1.1 | +| 531 | >>>gNB CU-CP Measurements | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 532 | >>>>RRC connection related measurements | STRUCTURE | | Refer to <i>gNB CU-CP Measurements</i> structure in 8.1.1.12 where this parameter is defined | + +In addition to using the above RAN Parameters for Policy conditions, this service style also uses RAN parameters defined in Clause 8.1. Accordingly, this service style supports Policy Conditions using the RAN parameters defined in Clauses 8.1, 8.5.1 and those covered in the above table. + +### 8.5.5.1 UE admission control request + +#### 8.5.5.1.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.5.1. + +#### 8.5.5.1.2 Offset + +Editor's Note: FFS + +### 8.5.5.2 RACH backoff control request + +#### 8.5.5.2.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.5.2. + +#### 8.5.5.2.2 Offset + +Editor's Note: FFS + +### 8.5.5.3 Access barring control request + +#### 8.5.5.3.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.5.3. + +#### 8.5.5.3.2 Offset + +Editor's Note: FFS + +### 8.5.5.4 RRC Connection Release request + +#### 8.5.5.4.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.5.3. + +#### 8.5.5.4.2 Offset + +Editor's Note: FFS + +### 8.5.5.5 RRC Connection Reject request + +#### 8.5.5.5.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.5.3. + +#### 8.5.5.5.2 Offset + +Editor's Note: FFS + +## 8.5.6 Dual Connectivity Policy + +### 8.5.6.0 Common RAN Parameters for Dual Connectivity Policy + +The RAN Parameters pertaining to POLICY Conditions for the “Dual Connectivity Control” policy service style used across all POLICY actions of the policy service style are listed in the below table. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key flag | Parameter description | +|------------------|----------------------------------------|--------------------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 501 | Target Secondary Node | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 | +| 502 | >CHOICE E2 Node Component Type | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 503 | >>NG-RAN gNB DU | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 504 | >>>gNB DU Measurements | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 505 | >>>List of NR cells | LIST | | Refer to <i>gNB DU Measurements</i> structure in 8.1.1.14 where this parameter is defined | +| 506 | >>>>NR Cell Item | STRUCTURE | | Refer to <i>gNB DU Measurements</i> structure in 8.1.1.14 where this parameter is defined | +| 507 | >>>>>Radio Resource Utilization | STRUCTURE | | Refer to <i>Radio Resource Utilization</i> structure in 8.1.1.14 where this parameter is defined. This has load measurements in terms of PRB usage. | +| 508 | >>>>>Number of active UE measurements | STRUCTURE | | Refer to <i>Number of active UE measurements</i> structure in 8.1.1.14 where this parameter is defined. This has load measurements in terms of number of active UEs. | +| 509 | >>>>>Slice Available Capacity List | STRUCTURE | | Refer to <i>Slice Available Capacity List</i> in 8.1.1.1 | +| 510 | >>>List of logical channels | LIST | | | +| 511 | >>>>Logical Channel Item | STRUCTURE | | | +| 512 | >>>>>Buffer Occupancy | ELEMENT | FALSE | Refer to <i>L2 MAC State Variables</i> structure in 8.1.1.4 where this parameter is defined. | +| 511 | >>NG-RAN gNB CU-CP | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 512 | >>>RRC connection related measurements | STRUCTURE | | Refer to <i>gNB CU-CP Measurements</i> structure in 8.1.1.12 where this parameter is defined | +| 521 | >>NG-RAN gNB | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 522 | >>>gNB DU Measurements | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 523 | >>>List of NR cells | LIST | | Refer to <i>gNB DU Measurements</i> structure in 8.1.1.14 where this parameter is defined | +| 524 | >>>>NR Cell Item | STRUCTURE | | Refer to <i>gNB DU Measurements</i> structure in 8.1.1.14 where this parameter is defined | +| 525 | >>>>>Radio Resource Utilization | STRUCTURE | | Refer to <i>Radio Resource Utilization</i> structure in 8.1.1.14 where this parameter is defined. This has load measurements in terms of PRB usage. | +| 526 | >>>>>Number of active UE measurements | STRUCTURE | | Refer to <i>Number of active UE measurements</i> structure in 8.1.1.14 where this parameter is defined. This has load measurements in terms of number of active UEs. | +| 527 | >>>>>Slice Available Capacity List | STRUCTURE | | Refer to <i>Slice Available Capacity List</i> in 8.1.1.1 | +| 528 | >>>List of logical channels | LIST | | Buffer Occupancy (BO) in number of bytes as defined in TS 25.321 [27] clause 8.2.2(c).LCID indicates logical channel ID. | + +| | | | | | +|-----|-----------------------------------------|-----------|-------|--------------------------------------------------------------------------------------------------------------------------| +| 529 | >>>>Logical Channel Item | STRUCTURE | | Buffer Occupancy (BO) in number of bytes as defined in TS 25.321 [27] clause 8.2.2(c).LCID indicates logical channel ID. | +| 530 | >>>>>Buffer Occupancy | ELEMENT | FALSE | Refer to <i>L2 MAC State Variables</i> structure in 8.1.1.4 where this parameter is defined. | +| 531 | >>>gNB CU-CP Measurements | STRUCTURE | | Refer to <i>E2 Node</i> structure in 8.1.1.11 where this parameter is defined | +| 532 | >>>>RRC connection related measurements | STRUCTURE | | Refer to <i>gNB CU-CP Measurements</i> structure in 8.1.1.12 where this parameter is defined | + +In addition to using the above RAN Parameters for Policy conditions, this service style also uses RAN parameters defined in Clause 8.1. Accordingly, this service style supports Policy Conditions using the RAN parameters defined in Clauses 8.1, 8.5.1 and those covered in the above table. + +### 8.5.6.1 DC Secondary Node Addition Control + +#### 8.5.6.1.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.6.1. + +#### 8.5.6.1.2 Offset + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|----------------------------|--------------------------|----------|--------------------------|------------------------------------------| +| 161 | B1 Event Threshold Offset | STRUCTURE | | | <i>EventB1</i> IE in 8.1.1.10 | +| 162 | >RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 163 | >RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 164 | >SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 165 | >Hysteresis Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 170 | B2 Event Threshold offset | STRUCTURE | | | <i>EventB2</i> IE in 8.1.1.10 | +| 171 | >B2-Threshold-NR offset | STRUCTURE | | | <i>EventB2</i> IE in 8.1.1.10 | +| 172 | >>RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 173 | >>RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 174 | >>SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 175 | >>Hysteresis Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 176 | >B2-Threshold-EUTRA offset | STRUCTURE | | | <i>EventB2</i> IE in 8.1.1.10 | +| 177 | >>RSRP Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 178 | >>RSRQ Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 179 | >>SINR Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | +| 180 | >>Hysteresis Offset | ELEMENT | FALSE | INTEGER | Offsets to be applied to default values, | + +## 8.5.6.2 DC Secondary Node Modification Control + +### 8.5.6.2.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.6.2. + +### 8.5.6.2.2 Offset + +The RAN parameters associated with this policy type are listed in the table in Clause 8.5.4.1.2. + +## 8.5.6.3 PSCell Change cell for Secondary Cell Group + +### 8.5.6.3.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.6.3. + +### 8.5.6.3.2 Offset + +The RAN parameters associated with this policy type are listed in the table in Clause 8.5.4.1.2. + +## 8.5.6.4 DC Secondary Node Change Control + +### 8.5.6.4.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.6.4. + +### 8.5.6.4.2 Offset + +The RAN parameters associated with this policy type are listed in the table in Clause 8.5.4.1.2. + +## 8.5.7 Carrier Aggregation Policy + +### 8.5.7.0 Common RAN Parameters for Carrier Aggregation Policy + +The RAN Parameters pertaining to POLICY Conditions for the “Carrier Aggregation Control” policy service style used across all POLICY actions of the policy service style are listed in the below table. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key flag | Parameter description | +|------------------|-----------------------------------------|--------------------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 501 | List of secondary cells setup | LIST | | <i>Scell To Be Setup List</i> IE in TS 38.473 [19] clause 9.2.2.1 | +| 502 | >Secondary cell setup Item | STRUCTURE | | <i>Scell To Be Setup Item</i> IEs IE in TS 38.473 [19] clause 9.2.2.1 | +| 503 | >>CHOICE Secondary cell | STRUCTURE | | | +| 504 | >>>NR SCell | STRUCTURE | | 8.1.1.1 | +| 505 | >>>>PM Measurements | STRUCTURE | | Refer to <i>PM Measurements</i> structure in 8.1.1.1 | +| 506 | >>>>>Radio Resource Status | STRUCTURE | | Refer to <i>Radio Resource Utilization</i> structure in 8.1.1.1 where this parameter is defined. This has load measurements in terms of PRB usage. | +| 507 | >>>>>Number of active UEs in the cell | ELEMENT | FALSE | Refer to <i>Number of active UE measurements</i> structure in 8.1.1.1 where this parameter is defined. This has load measurements in terms of number of active UEs. | +| 508 | >>>>>Composite available capacity group | STRUCTURE | | Refer to <i>Composite Available Capacity Group</i> structure in 8.1.1.1 | +| 509 | >>>>>Slice available capacity list | STRUCTURE | | Refer to <i>Slice Available Capacity List</i> in 8.1.1.1 | +| 511 | >>>E-UTRA SCell | STRUCTURE | | 8.1.1.2 | +| 512 | >>>>PM Measurements | STRUCTURE | | Refer to <i>PM Measurements</i> structure in 8.1.1.2 | +| 513 | >>>>>Radio Resource Status | STRUCTURE | | Refer to <i>Radio Resource Utilization</i> structure in 8.1.1.2 where this parameter is defined. This has load measurements in terms of PRB usage. | +| 514 | >>>>>Composite Available capacity group | STRUCTURE | | Refer to <i>Composite Available Capacity Group</i> structure in 8.1.1.2 | +| 515 | >>>>>Number of active UEs in the cell | ELEMENT | FALSE | Refer to <i>Number of active UE measurements</i> structure in 8.1.1.12 where this parameter is defined. This has load measurements in terms of number of active UEs. | +| 516 | List of logical channels | LIST | | Buffer Occupancy (BO) in number of bytes as defined in TS 25.321 [27] clause 8.2.2(c).LCID indicates logical channel ID. | +| 517 | >Logical Channel Item | STRUCTURE | | Buffer Occupancy (BO) in number of bytes as defined in TS 25.321 [27] clause 8.2.2(c).LCID indicates logical channel ID. | +| 518 | >>LCID | ELEMENT | TRUE | <i>LogicalChannelIdentity</i> IE in TS 38.331 [22] Sec 6 | +| 519 | >>Buffer Occupancy | ELEMENT | FALSE | Refer to <i>L2 MAC State Variables</i> structure where this parameter is defined | + +In addition to using the above RAN Parameters for Policy conditions, this service style also uses RAN parameters defined in Clause 8.1. Accordingly, this service style supports Policy Conditions using the RAN parameters defined in Clauses 8.1, 8.5.1 and those covered in the above table. + +### 8.5.7.1 Secondary cell Addition control + +#### 8.5.7.1.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.7.1. + +#### 8.5.7.1.2 Offset + +The RAN parameters associated with this policy type are listed in the table in Clause 8.5.4.1.2. + +### 8.5.7.2 Secondary cell Modification control + +#### 8.5.7.2.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.7.2. + +#### 8.5.7.2.2 Offset + +The RAN parameters associated with this policy type are listed in the table in Clause 8.5.4.1.2. + +## 8.5.8 Idle Mode Mobility Policy + +### 8.5.8.0 Common RAN Parameters for Idle Mode Mobility Policy + +The RAN Parameters pertaining to POLICY Conditions for the “Idle Mode Mobility Control” policy service style used across all POLICY actions of the policy service style are listed in the below table. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key flag | Parameter description | +|------------------|--------------------|--------------------------|----------|-----------------------| +| 501 | | | | | + +In addition to using the above RAN Parameters for POLICY conditions, this service style also uses RAN parameters defined in Clause 8.1. Accordingly, this service style supports Policy Conditions using the RAN parameters defined in Clauses 8.1, 8.5.1 and those covered in the above table. + +### 8.5.8.1 Cell reselection priority control + +#### 8.5.8.1.1 Control action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.8.1. + +#### 8.5.8.1.2 Offset + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.5.4. For the priority and sub priority parameters, values are used to set offsets with respect to the default behaviour, i.e., carrier frequency with fourth priority and an offset of +1 shall be considered as third priority + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------|--------------------------|----------|-----------------------------------------|---------------------------------------------------------| +| 1 | Cell Reselection Priorities | STRUCTURE | | | <i>IdleModeMobilityControlInfo</i> IE in TS 36.331 [23] | +| 2 | >Frequency Priority List E-UTRA | LIST | | | <i>FreqPriorityListEUTRA</i> IE in TS 38.331 [22] | +| 3 | >>Frequency Priority Item E-UTRA | STRUCTURE | | | <i>FreqPriorityEUTRA</i> IE in TS 38.331 [22] | +| 4 | >>>Carrier Frequency | ELEMENT | FALSE | <i>carrierFreq</i> IE in TS 38.331 [22] | | +| 5 | >>>Cell Reselection Priority offset | ELEMENT | FALSE | INTEGER | <i>cellReselectionPriority</i> IE in TS 38.331 [22] | +| 6 | >>>Cell Reselection Sub Priority offset | ELEMENT | FALSE | INTEGER | <i>cellReselectionSubPriority</i> IE in TS 38.331 [22] | +| 7 | >Frequency Priority List NR | LIST | | | <i>FreqPriorityListNR</i> IE in TS 38.331 [22] | +| 8 | >>Frequency Priority Item NR | STRUCTURE | | | <i>FreqPriorityNR</i> IE in TS 38.331 [22] | +| 9 | >>>Carrier Frequency | ELEMENT | FALSE | <i>carrierFreq</i> IE in TS 38.331 [22] | | +| 10 | >>>Cell Reselection Priority offset | ELEMENT | FALSE | INTEGER | <i>cellReselectionPriority</i> IE in TS 38.331 [22] | +| 11 | >>>Cell Reselection Sub Priority offset | ELEMENT | FALSE | INTEGER | <i>cellReselectionSubPriority</i> IE in TS 38.331 [22] | +| 12 | >T-320 timer expiry offset | ELEMENT | FALSE | INTEGER | <i>t320</i> IE in TS 38.331 [22] | + +## 8.5.9 Measurement Reporting Configuration Policy + +The RAN Parameters pertaining to Policy Conditions for the “Measurement Report Configuration Control” policy service style are given below. + +In addition, this service style also uses RAN parameters defined in Clause 8.1. Thus, this service style currently supports Policy Conditions using the RAN parameters defined in Clauses 8.1 and 8.5.1 in addition to those defined below. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------------------|--------------------------|----------|--------------------------------|-----------------------------------------------------------------------------| +| 300 | List of Serving Beam Info | LIST | | | List of information about source beams belonging to the E2 Node. | +| 301 | >Serving Beam Info Item | STRUCTURE | | | | +| 302 | >>Beam ID | ELEMENT | FALSE | Defined in [4] clause 6.2.2.16 | | +| 303 | >>Serving Cell CGI | ELEMENT | FALSE | OCTET STRING | Defined in Clause 9.3.36. | +| 304 | >>List of Neighbouring Cells | LIST | | | List of neighbouring cell IDs of this source beam belonging to the E2 Node. | +| 305 | >>>Neighbouring Cell CGI | ELEMENT | FALSE | OCTET STRING | Defined in Clause 9.3.36. | + +### 8.5.9.1 Add MR Configuration + +#### 8.5.9.1.1 Control Action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.10.1. + +#### 8.5.9.1.2 Offset + +**Editor's Note:** FFS + +### 8.5.9.2 Modify MR Configuration + +#### 8.5.9.2.1 Control Action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.10.2. + +#### 8.5.9.2.2 Offset + +RAN parameters in clause 8.4.10.2, where appropriate, may be modified via “offsets”. The offsets are provided by Policy Actions. See clause 6.6.3 for the policy “offset” approach. + +### 8.5.9.3 Delete MR Configuration + +#### 8.5.9.3.1 Control Action + +The RAN parameters associated with this policy type are listed in the table in Clause 8.4.10.3. + +#### 8.5.9.3.2 Offset + +**Editor's Note:** FFS + +## 8.5.10 Beamforming Configuration Policy + +### 8.5.10.0 Common RAN Parameters for Beamforming Configuration Policy + +The RAN Parameters pertaining to POLICY Conditions for the “Beamforming Configuration Control” policy service style used across all POLICY actions of the policy service style are listed in the below table. + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------|--------------------------|----------|--------------------------|----------------------------------------------------------------------------------------------| +| 501 | MIMO Mode Index | ELEMENT | TRUE | INTEGER (1..2, ...) | Value = 1 means the SU (single-user) MIMO mode. Value 2 means the MU (multi-user) MIMO mode. | + +In addition to using the above RAN Parameters for Policy conditions, this service style also uses RAN parameters defined in Clause 8.1. Accordingly, this service style supports Policy Conditions using the RAN parameters defined in Clauses 8.1, 8.5.1 and those covered in the above table. + +## 8.5.10.1 Non-GoB BF Mode Configuration + +### 8.5.10.1.1 Control Action + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------------------|--------------------------|----------|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 502 | Non-GoB Beamforming Mode Index | ELEMENT | FALSE | INTEGER (0.. 65535, ...) | <p>The index is used for Non- Grid of Beams (Non-GoB) beamforming optimization for 5G mMIMO deployments [32]. Each BF mode implies a vendor-specific proprietary Non-GoB BF algorithm that are not standardized [33], for which each E2 Node, who supports the Non-GoB beamforming optimization feature, provides the number of different Non-GoB BF mode(s) supported by its scheduler indexed from 1 to n. The AI/ML model for Non-GoB beamforming optimization is trained by data and measurements related to each BF mode and/or MIMO mode, for which the trained AI/ML model, based on collected data, configures the E2 Node with the best inferred Non-GoB BF mode index to be used for each UE, where such configuration could be done separately for the case of Single User- and/or Multi-user MIMO [32]. The Value = 0 means release of Non-GoB BF mode for the UE of subject.</p> | + +### 8.5.10.1.2 Offset + +This policy type does not support the offset approach. + +## 8.5.10.2 GoB BF Configuration + +### 8.5.10.2.1 Control Action + +| RAN Parameter ID | RAN Parameter | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|------------------|--------------------------|----------|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 503 | RI-LI-PMI config | STRUCTURE | FALSE | | Precoding Matrix Indicator (PMI), Rank Indicator (RI), Layer Indicator (LI) in TS 38.214 [36] Clause 5.2.2.2. The AI/ML model for CSI-RS and DMRS optimization infers the best PMI, RI, LI to be used for each UE [32]. | +| 504 | > RI | ELEMENT | FALSE | INTEGER (0,...,8) | RI in TS 38.214 [36] Clause 5.2.2.2. The value=0 means RI-PMI reporting is not supported for the UE of interest. | +| 505 | > LI | ELEMENT | FALSE | INTEGER (0,...,8) | LI in TS 38.214 [36] Clause 5.2.2.2. The value=0 means LI-reporting is not supported for the UE of interest. | +| 506 | > i1 | STRUCTURE | FALSE | | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 507 | >> i11 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 508 | >> i12 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 509 | >> i13 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 510 | >> i131 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 511 | >> i132 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 512 | >> i14 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 513 | >> i141 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | + +| | | | | | | +|-----|---------|-----------|-------|---------------------|----------------------------------------------------| +| 514 | >> i142 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 515 | >> i143 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 516 | >> i15 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 517 | >> i161 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 518 | >> i162 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 519 | >> i171 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 520 | >> i172 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 521 | >> i173 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 522 | >> i174 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 523 | >> i181 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 524 | >> i182 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 525 | >> i183 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 526 | >> i184 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 527 | > i2 | STRUCTURE | FALSE | | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 528 | >> i20 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 529 | >> i21 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 530 | >> i211 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | + +| | | | | | | +|-----|-----------------|---------|-------|---------------------|-------------------------------------------------------------------------------------------------| +| 531 | >> i212 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 532 | >> i22 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 533 | >> i221 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 534 | >> i222 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 535 | >> i231 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 536 | >> i232 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 537 | >> i233 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 538 | >> i234 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 539 | >> i241 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 540 | >> i242 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 541 | >> i243 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 542 | >> i244 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 543 | >> i251 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 544 | >> i252 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 545 | >> i253 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 546 | >> i254 | ELEMENT | FALSE | INTEGER (0,...,256) | PMI coefficients in TS 38.214 [36] Clause 5.2.2.2. | +| 547 | > Subband Index | ELEMENT | FALSE | INTEGER (0,...,19) | Subband index for PMI reporting in TS 38.214 [36] Clause 5.2.1.4. The value=0 means Subband PMI | + +| | | | | | | +|-----|----------------|---------|-------|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | | reporting is not supported for the UE of interest. | +| 548 | P-2 Beam Index | ELEMENT | FALSE | INTEGER (0...256) | P-2 beam index in TS 38.912 [37] Clause 8.2.1.6.1. The AI/ML model for CSI-RS and DMRS optimization infers the best P-2 beam index to be used for each UE [32]. The value=0 means P-2-beam management is not supported for the UE of interest. | + +### 8.5.10.2.2 Offset + +This policy type does not support the offset approach. + +## 8.6 RAN parameters for QUERY services + +### 8.6.1 RAN Parameters for Query Service Style 1 + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|-----------------------------------------------|--------------------------|----------|-------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell Context Information | ELEMENT | FALSE | OCTET STRING | <i>Served Cell Information</i> IE in TS 38.473 [19] clause 9.3.1.10. This shall be used to report Cell Context information. | +| 2 | Neighbour Relation Table | STRUCTURE | FALSE | 9.3.38<br><i>Neighbour Relation Information</i> | This shall be used to report neighbour relation information of the serving cells. | +| 3 | Number of supported Non-GoB beamforming modes | ELEMENT | FALSE | INTEGER (0.. 65535, ...) | This shall be used to report the number of Non- Grid of Beams (Non-GoB) beamforming modes supported by the E2 Node for mMIMO Non-GoB beamforming optimization for 5G mMIMO deployments [32]. Each BF mode implies a vendor-specific proprietary Non-GoB BF algorithm that are not standardized [33], for which each E2 Node, who supports the Non-GoB beamforming optimization feature, provides the number of different Non-GoB BF mode(s) supported by its scheduler indexed from 1 to n. The AI/ML model for Non-GoB beamforming optimization is trained by data and measurements related to each BF mode and/or MIMO mode, for which the trained AI/ML model, based on collected data, configures the E2 Node with the best inferred Non-GoB BF mode | + +| | | | | | | +|----|------------------------------------------|-----------|-------|-------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | | index to be used for each UE, where such configuration could be done separately for the case of Single User- and/or Multi-user MIMO [32]. If Non-GoB beamforming optimization is not supported by a cell of interest, then the value "0" shall be replied. | +| 4 | MIB | ELEMENT | FALSE | OCTET STRING | <i>MIB</i> IE in TS 38.331 [22] Clause 6.2.2. This shall be used to report MIB of the serving cell | +| 5 | Serving Cell Config Common | STRUCTURE | FALSE | 9.3.60 | This shall be used to report common parameters of the serving cell contained in <i>ServingCellConfigCommon</i> IE in TS 38.331 [22] Clause 6.3.2. | +| 6 | O-DU Compression Support | STRUCTURE | | | | +| 7 | >BFW Compression Support | STRUCTURE | | | Identifies the O-DU supported compression methods from the list defined in O-RAN-WG4.CUS [34] Clause 7.4.7.1.1 | +| 8 | >>no compression | ELEMENT | FALSE | BOOLEAN | If this parameter is set to True, all other parameters shall either not be included or be set to False and shall be ignored by the receiving end. | +| 9 | >>block floating point (BFP) | ELEMENT | FALSE | BOOLEAN | | +| 10 | >>block scaling | ELEMENT | FALSE | BOOLEAN | | +| 11 | >>m-law | ELEMENT | FALSE | BOOLEAN | | +| 12 | >>beam-space compression Type I | ELEMENT | FALSE | BOOLEAN | | +| 13 | >>beam-space compression Type II | ELEMENT | FALSE | BOOLEAN | | +| 14 | CSI-ReportConfig | ELEMENT | FALSE | OCTET STRING | CSI-ReportConfig IE in TS 38.331 [22] Clause 6.3.1. This shall be used to report the CSI report configurations which includes Codebook Configurations (e.g., Type I, Type II etc.) supported by the E2 Node [32]. | +| 15 | Supported GoB-beamforming configurations | STRUCTURE | FALSE | | Beam <IOC> in TS 28.541 [35] Clause 4.3.40. This shall be used to report the set of GoB beamforming configurations (e.g., indexes, azimuth directions, elevation directions etc.) supported by the E2 Node [32]. | +| 16 | > beamIndex | ELEMENT | FALSE | INTEGER (0...256) | Beam <IOC> Attribute Properties in TS 28.541 [35] Clause 4.4.1. | +| 17 | > beamType | ELEMENT | FALSE | ENUMERATED ('SSB-BEAM', 'CSI-BEAM') | As per Beam <IOC> Attribute Properties in TS 28.541 [35] Clause 4.4.1, allowed value for this field is 'SSB-BEAM'. The value 'CSI-BEAM' is Optional. | +| 18 | > beam- | ELEMENT | FALSE | INTEGER (-1800...1800) | Beam <IOC> Attribute Properties in TS 28.541 [35] Clause 4.4.1. | + +| | | | | | | +|----|-------------------|---------|-------|----------------------|-----------------------------------------------------------------| +| | Azimuth | | | | | +| 19 | > beamTilt | ELEMENT | FALSE | INTEGER (-900...900) | Beam <IOC> Attribute Properties in TS 28.541 [35] Clause 4.4.1. | +| 20 | > beam-HorizWidth | ELEMENT | FALSE | INTEGER (0...3599) | Beam <IOC> Attribute Properties in TS 28.541 [35] Clause 4.4.1. | +| 21 | > beam-VertWidth | ELEMENT | FALSE | INTEGER (0...1800) | Beam <IOC> Attribute Properties in TS 28.541 [35] Clause 4.4.1. | + +## 8.6.2 RAN Parameters for Query Service Style 2 + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Value Type | Key Flag | RAN Parameter Definition | Semantics Description | +|------------------|--------------------|--------------------------|----------|---------------------------------|-----------------------------------------------| +| 1 | Cell Global ID | ELEMENT | FALSE | 9.3.36<br><i>Cell Global ID</i> | Used to report the Serving Cell ID of the UE. | + +In addition to using the above RAN Parameters, this service style also uses RAN parameters defined in Clause 8.1.1. + +# 9 Elements for E2SM Service Model + +## 9.1 General + +## 9.2 Message Functional Definition and Content + +### 9.2.1 Messages for RIC Functional procedures + +#### 9.2.1.1 RIC Event Trigger Definition IE + +This information element is part of the RIC SUBSCRIPTION REQUEST message sent by the Near-RT RIC to an E2 Node and is required for event triggers used to initiate REPORT, INSERT and POLICY actions. + +Direction: NEAR-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------------|----------|-------|-----------------------|--------------------------------| +| <b>CHOICE RIC Event Trigger Definition IE Format</b> | | | | | +| >E2SM-RC Event Trigger Definition Format 1 | M | | 9.2.1.1.1 | Used for Event Trigger Style 1 | +| >E2SM-RC Event Trigger Definition Format 2 | M | | 9.2.1.1.2 | Used for Event Trigger Style 2 | +| >E2SM-RC Event Trigger Definition Format 3 | M | | 9.2.1.1.3 | Used for Event Trigger Style 3 | +| >E2SM-RC Event Trigger Definition Format 4 | M | | 9.2.1.1.4 | Used for Event Trigger Style 4 | +| >E2SM-RC Event Trigger Definition Format 5 | M | | VOID | Format 5 has been deprecated | + +### 9.2.1.1.1 E2SM-RC Event Trigger Definition Format 1: Message Event + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|----------|-----------------------|--------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of Messages for Event Trigger | | 1..<maxnoof Messages> | | | +| >Event Trigger Condition ID | M | | 9.3.21 | | +| >CHOICE Message Type | M | | | | +| >>Network Interface | | | | | +| >>>NI Type | M | | 9.3.32 | 3GPP Network Interface Type | +| >>>NI Identifier | O | | 9.3.33 | “Any” Network Interface instance to be used if absent. | +| >>>NI Message | O | | 9.3.34 | Network Interface Message ID. This can indicate whether NUA (Non-UE Associated) or UA (UE-Associated). | +| >>RRC | | | | | +| >>>RRC Message ID | M | | 9.3.35 | RRC Message ID | +| >Message Direction | O | | ENUMERATED (incoming, outgoing, ...) | Indicates message arrival or departure for event triggering (“Any” direction if not included). | +| >Associated UE Info | O | | 9.3.26 | Indicates applicable UE(s) for event triggering associated to each message event (“Any” UE if not included). Shall not be included in case of NUA type NI message. | +| >Associated UE Event | O | | 9.3.28 | Indicates specific UE event(s) defined in Clause 8.1.5 for event triggering associated to each message event. | +| >Logical OR | O | | 9.3.25 | | +| Global Associated UE Info | O | | 9.3.26 | Indicates applicable UE(s) for event triggering, applied to all the message events uniformly. This IE shall override any <i>Associated UE Info</i> IE included for some message events. Shall not be included in case a NUA type NI message event is configured. | + +| Range bound | Explanation | +|-----------------|-------------------------------------------------------------------------------------------------------------| +| maxnoofMessages | Maximum number of Messages in a given E2 node for which event trigger can be defined. The value is <65535>. | + +### 9.2.1.1.2 E2SM-RC Event Trigger Definition Format 2: Call Process Breakpoint + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|-----------------------|---------------------------------------------------------------------------------------------------------------------------| +| Call Process Type ID | M | | 9.3.15 | | +| Call Breakpoint ID | M | | 9.3.49 | | +| Associated E2 Node Info | O | | 9.3.29 | Used to set optional E2 Node related information for event triggering. RAN Parameters in Clause 8.1.2 shall only be used. | +| Associated UE Info | O | | 9.3.26 | Indicates applicable UE(s) for event triggering (“Any” UE if not included). | + +### 9.2.1.1.3 E2SM-RC Event Trigger Definition Format 3: E2 Node Information Change + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|----------|----------------------------|-----------------------|-----------------------------| +| Sequence of E2 Node Information Change | | 1..<maxnoof E2InfoChanges> | | | +| >Event Trigger Condition ID | M | | 9.3.21 | | +| >E2 Node Information Change ID | M | | INTEGER (1..512, ...) | Defined in 7.3.4. | +| >Associated Cell Info | O | | 9.3.27 | "Any" cell if not included. | +| >Logical OR | O | | 9.3.25 | | + +| Range bound | Explanation | +|----------------------|-------------------------------------------------------------------------------------------------------------| +| maxnoofE2InfoChanges | Maximum number of E2 Node information changes for which event trigger can be defined. The value is <65535>. | + +### 9.2.1.1.4 E2SM-RC Event Trigger Definition Format 4: UE Information Change + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------|----------|----------------------------|-------------------------------------|-----------------------------------------------------------------------------------------------------------------------| +| Sequence of UE Information Change | | 1..<maxnoof UEInfoChanges> | | | +| >Event Trigger Condition ID | M | | 9.3.21 | | +| > <b>CHOICE</b> Trigger Type | M | | | | +| >> <b>RRC State</b> | | | | | +| >>>RRC State List | | 1..<maxnoof RRCstate> | | | +| >>>>State Changed To | M | | 9.3.37 | | +| >>>>Logical OR | O | | 9.3.25 | | +| >> <b>UE Identifier</b> | | | | | +| >>>UE Identifier Change ID | M | | INTEGER (1..512, ...) | Defined in 7.3.5. | +| >> <b>L2 State</b> | | | | Used to set conditions for PDCP, RLC and MAC state variable reporting | +| >>>Associated L2 Variables | M | | 9.3.29 | RAN Parameters in Clauses 8.1.1.4 and 8.1.1.8 shall only be used. | +| >> <b>UE Context Info</b> | | | | | +| >>>Associated UE Context Info Variables | M | | 9.3.29 | RAN Parameters in Clause 8.1.1.17 | +| >> <b>L2 MAC Scheduler related Change</b> | | | | | +| >>> <b>CHOICE</b> L2 MAC Scheduler Change Type | M | | | | +| >>>> <b>MIMO and Beamforming Configuration</b> | | | | Used only for POLICY Service Style 9 | +| >>>>>MIMO Transmission Mode State | M | | ENUMERATED (enabled, disabled, ...) | Used to set condition when the MAC scheduler enables or disables the MIMO transmission mode for the associated UE(s). | +| >Associated UE Info | O | | 9.3.26 | Indicates applicable UE(s) for event triggerin ("ny" UE if not included). | +| >Logical OR | O | | 9.3.25 | | + +| Range bound | Explanation | +|----------------------|--------------------------------------------------------------------------------------------------------| +| maxnoofUEInfoChanges | Maximum number of UE information changes for which event trigger can be defined. The value is <65535>. | +| maxnoofRRCstate | Maximum number of RRC states for which event trigger can be defined. The value is <8>. | + +#### 9.2.1.1.5 VOID + +### 9.2.1.2 RIC ACTION DEFINITION IE + +This information element is part of the RIC SUBSCRIPTION REQUEST message sent by the Near-RT RIC to an E2 Node. In this service model, this information element provides additional information for the nominated RIC Action. + +Direction: NEAR-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------------|----------|-------|-----------------------|------------------------------------------------------------------| +| RIC Style Type | M | | 9.3.3 | | +| <b>CHOICE</b> RIC Action Definition IE Format | | | | | +| >E2SM-RC Action Definition Format 1 | M | | 9.2.1.2.1 | Used by REPORT service | +| >E2SM-RC Action Definition Format 2 | M | | 9.2.1.2.2 | Used by POLICY service when encoding a list of Policy Conditions | +| >E2SM-RC Action Definition Format 3 | M | | 9.2.1.2.3 | Used by INSERT service except style 255 | +| >E2SM-RC Action Definition Format 4 | M | | 9.2.1.2.4 | Used only by INSERT service style 255 | + +#### 9.2.1.2.1 E2SM-RC Action Definition Format 1 + +The *E2SM-RC Action Definition Format 1* IE supports a REPORT service and is encoded as a list of RAN parameters to be reported, each with a RAN Parameter ID and RAN Parameter Definition. RAN parameters for REPORT service are defined in Clause 8.2. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|--------------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Parameters to be Reported List | | 1..<maxnoofParametersToReport> | | | +| >RAN Parameter ID | M | | 9.3.8 | Only the RAN Parameter ID values declared in RAN Function Definition may be included. | +| >RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list).<br>If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported.<br>Only the RAN Parameter ID values declared in RAN Function Definition may be included. | + +| Range bound | Explanation | +|---------------------------|----------------------------------------------------------------------------------------------------------------| +| maxnoofParametersToReport | Maximum no. of RAN parameters supported by <i>E2SM-RC Action Definition Format 1</i> IE. The value is <65535>. | + +#### 9.2.1.2.2 E2SM-RC Action Definition Format 2 + +The *E2SM-RC Action Definition Format 2* IE supports Policy services encoded as a list of Policy Conditions, each with a Policy Condition definition described using *RAN Parameter Conditional Criteria Definition* IE in terms of a list of RAN parameters with test conditions and a *Policy Action* IE command described in terms of a list of RAN parameters. The meaning of the RAN Parameter ID/Value pairs for each list is defined in Clause 8.5. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------|----------|------------------------------|-----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of Policy Conditions | | 1..<maxnoofPolicyConditions> | | | +| >Policy Action | M | | 9.3.20 | Defines policy to be applied for specific Policy Condition | +| >Policy Condition Definition | O | | 9.3.29 | Defines conditional test. | +| >Policy Condition ID | O | | 9.3.58 | For the case of Offset based policy, this identifier is used to determine the order in which Policy conditions are tested while searching for the first positive match | + +| Range bound | Explanation | +|-------------------------|------------------------------------------------------------------------------------------------------------------------------| +| maxnoofPolicyConditions | Maximum no. of Policy Condition in <i>E2SM-RC Action Definition Format 2</i> IE supported by RAN Function. Value is <65535>. | + +### 9.2.1.2.3 E2SM-RC Action Definition Format 3 + +The *E2SM-RC Action Definition Format 3* IE supports an INSERT service of the indicated *RIC Style Type* IE and is encoded by the Insert Indication ID and a list of RAN parameters. The meaning of the RAN Parameter ID(s) in the list is defined in Clause 8.3. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------------|----------|-------------------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Insert Indication ID | M | | 9.3.16 | Refer to Clause 7.5 | +| List of RAN parameters for Insert Indication | M | 1..<maxnoofAssociatedRANParameters> | | Refer to Clause 8.3 | +| >RAN Parameter ID | M | | 9.3.8 | Refer to Clause 8.3<br>Only the RAN Parameter ID values declared in RAN Function Definition may be included. | +| >RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list).<br>If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported.<br>Only the RAN Parameter ID values declared in RAN Function Definition may be included. | +| UE ID | O | | 9.3.10 | If included, indicates that the subscribed INSERT service, upon the associated event trigger occurs, shall be executed for this UE only.<br>In case of UE-related event triggers, the subscribed INSERT service shall not be executed unless the triggered event is related to this UE. | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------------------------------------------------------------| +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by <i>E2SM-RC Action Definition Format 3</i> IE for INSERT Indication. The value is <65535>. | + +#### 9.2.1.2.4 E2SM-RC Action Definition Format 4 + +The *E2SM-RC Action Definition Format 4* IE supports multiple Insert Indication actions of one or more requested INSERT services, where each Insert Indication action is encoded by Insert Indication ID and a list of RAN parameters. The meaning of the RAN Parameter ID/Value pairs for each list is defined in Clause 8.3. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------------|----------|-------------------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of Insert Styles for Multiple Actions | | 1..<maxnoofRICStyles> | | | +| >Requested Insert Style | M | | 9.3.3 | | +| >Sequence of Insert Indication Action Definition | | 1..<maxnoofInsertIndicationActions> | | | +| >>Insert Indication ID | M | | 9.3.16 | Refer to Clause 7.5 | +| >>List of RAN parameters for Insert Indication | | 1..<maxnoofAssociatedRANParameters> | | Refer to Clause 8.3 | +| >>>RAN Parameter ID | M | | 9.3.8 | Refer to Clause 8.3<br>Only the RAN Parameter ID values declared in RAN Function Definition may be included. | +| >>>RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list).<br>If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported.<br>Only the RAN Parameter ID values declared in RAN Function Definition may be included. | +| UE ID | O | | 9.3.10 | If included, indicates that the subscribed INSERT service, upon the associated event trigger occurs, shall be executed for this UE only.<br>In case of UE-related event triggers, the subscribed INSERT service shall not be executed unless the triggered event is related to this UE. | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------------------------------------------------------------| +| maxnoofRICStyles | Maximum no. of Insert Styles supported by <i>E2SM-RC Action Definition Format 4</i> IE for INSERT Indication. The value is <63>. | +| maxnoofInsertIndicationActions | Maximum no. of Insert indication actions supported by RAN Function. The value is <63>. | +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by <i>E2SM-RC Action Definition Format 4</i> IE for INSERT Indication. The value is <65535>. | + +### 9.2.1.3 RIC INDICATION HEADER IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to the Near-RT RIC and is required for REPORT action. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE <i>Indication Header Format</i> | | | | | +| >E2SM-RC Indication Header Format 1 | M | | 9.2.1.3.1 | | +| >E2SM-RC Indication Header Format 2 | M | | 9.2.1.3.2 | | +| >E2SM-RC Indication Header Format 3 | M | | 9.2.1.3.3 | | + +#### 9.2.1.3.1 E2SM-RC Indication Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------|-----------------------|----------------------------| +| Event Trigger Condition ID | O | | 9.3.21 | Event Trigger Condition ID | + +#### 9.2.1.3.2 E2SM-RC Indication Header Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------|----------|-------|-----------------------|-----------------------| +| UE ID | M | | 9.3.10 | | +| RIC Insert Style Type | M | | 9.3.3 | | +| Insert Indication ID | M | | 9.3.16 | Refer to Clause 7.5 | + +#### 9.2.1.3.3 E2SM-RC Indication Header Format 3 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------|-----------------------|-----------------------| +| Event Trigger Condition ID | O | | 9.3.21 | | +| UE ID | O | | 9.3.10 | | + +### 9.2.1.4 RIC INDICATION MESSAGE IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to the Near-RT RIC and is required for REPORT action. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------|----------|-------|-----------------------|------------------------------| +| <b>CHOICE</b> <i>Indication Message Format</i> | M | | | | +| >E2SM-RC Indication Message Format 1 | | | 9.2.1.4.1 | | +| >E2SM-RC Indication Message Format 2 | | | 9.2.1.4.2 | | +| >E2SM-RC Indication Message Format 3 | | | 9.2.1.4.3 | | +| >E2SM-RC Indication Message Format 4 | | | VOID | Format 4 has been deprecated | +| >E2SM-RC Indication Message Format 5 | | | 9.2.1.4.5 | | +| >E2SM-RC Indication Message Format 6 | | | 9.2.1.4.6 | | + +#### 9.2.1.4.1 E2SM-RC Indication Message Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|--------------------------------------------------|-----------------------|-----------------------| +| Sequence of RAN Parameters | | <i>1..<maxnoofAssociatedRANParameters></i> | | | +| >RAN Parameter ID | M | | 9.3.8 | | +| >RAN Parameter Value Type | M | | 9.3.11 | | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------------------------------------------| +| maxnoofAssociatedRANParameters | Maximum number of RAN Parameters supported by <i>E2SM-RC Indication Message Format 1</i> IE. The value is <65535>. | + +#### 9.2.1.4.2 E2SM-RC Indication Message Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------|----------|--------------------------------------------------|-----------------------|-----------------------| +| Sequence of UE Identifiers | | <i>1..<maxnoofUEID></i> | | | +| >UE ID | M | | 9.3.10 | | +| >Sequence of RAN Parameters | | <i>1..<maxnoofAssociatedRANParameters></i> | | | +| >>RAN Parameter ID | M | | 9.3.8 | | +| >>RAN Parameter Value Type | M | | 9.3.11 | | + +| Range bound | Explanation | +|--------------------------------|-----------------------------------------------------------------------------------------------------------------------------------| +| maxnoofUEID | Maximum number of UE Identifiers supported by <i>E2SM-RC Indication Message Format 2</i> IE to be reported. The value is <65535>. | +| maxnoofAssociatedRANParameters | Maximum number of RAN Parameters supported by <i>E2SM-RC Indication Message Format 2</i> IE to be reported. The value is <65535>. | + +### 9.2.1.4.3 E2SM-RC Indication Message Format 3 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------|----------|---------------------|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of Cell Information | | 1..<maxnoofCell ID> | | | +| >Cell Global ID | M | | 9.3.36 | | +| >Cell Context Information | O | | OCTET STRING | <i>Served Cell Information</i> IE in TS 38.473 [19] clause 9.3.1.10.<br>This IE shall be reported if RAN Parameter ID is set to “1” as described in Clause 8.2.3. | +| >Cell Deleted | O | | BOOLEAN | This IE shall be used to report deleted cells. The value shall be set to “True” for the deleted Cell Global ID.<br>This IE shall be reported if RAN Parameter ID is set to “2” as described in Clause 8.2.3. | +| >Neighbour Relation Table | O | | 9.3.38 | Provides information on neighbours of serving cell.<br>This IE shall be reported if RAN Parameter ID is set to “3” as described in Clause 8.2.3. | +| >MIB | O | | OCTET STRING | <i>MIB</i> IE in TS 38.331.<br>This IE shall be reported if RAN Parameter ID is set to “4” as described in Clause 8.2.3. | +| > Serving Cell Config Common | O | | 9.3.60 | Provides information on common parameters of the serving cell.<br>This IE shall be reported if RAN Parameter ID is set to “5” as described in Clause 8.2.3. | + +| Range bound | Explanation | +|---------------|-------------------------------------------------------------------------------------------------------------------------------------| +| maxnoofCellID | Maximum number of Cell Identifiers supported by <i>E2SM-RC Indication Message Format 3</i> IE to be reported. The value is <65535>. | + +#### 9.2.1.4.4 VOID + +#### 9.2.1.4.5 E2SM-RC Indication Message Format 5 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|--------------------------------------------------------------------------------------------|-----------------------|------------------------------| +| List of RAN parameters requested | | <i>0..<maxnoofassociatedranparameters>< i=""></maxnoofassociatedranparameters><></i> | | | +| >RAN Parameter ID | M | | 9.3.8 | Refer to table in Clause 8.3 | +| >RAN Parameter Value Type | M | | 9.3.11 | Refer to table in Clause 8.3 | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------------------------------------| +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function for a specific Control action. The value is <65535>. | + +#### 9.2.1.4.6 E2SM-RC Indication Message Format 6 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------|----------|--------------------------------------------------------------------------------------------|-----------------------|------------------------------| +| Sequence of Insert Styles for Multiple Actions | | <i>1..<maxnoofricstyles>< i=""></maxnoofricstyles><></i> | | | +| >Indicated Insert Style | M | | 9.3.3 | | +| >Sequence of Insert Indication Actions | | <i>1..<maxnoofinsertindicationactions>< i=""></maxnoofinsertindicationactions><></i> | | | +| >>Insert Indication ID | M | | 9.3.16 | Refer to Clause 7.5 | +| >>List of RAN parameters requested | | <i>0..<maxnoofassociatedranparameters>< i=""></maxnoofassociatedranparameters><></i> | | | +| >>>RAN Parameter ID | M | | 9.3.8 | Refer to table in Clause 8.3 | +| >>>RAN Parameter Value Type | M | | 9.3.11 | Refer to table in Clause 8.3 | + +| Range bound | Explanation | +|--------------------------------|------------------------------------------------------------------------------------------------------------------------| +| maxnoofRICStyles | Maximum no. of Insert Styles supported for multiple actions. The value is <63>. | +| maxnoofInsertIndicationActions | Maximum no. of Insert indication actions supported by RAN Function. The value is <63>. | +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function for a specific Insert indication action. The value is <65535>. | + +#### 9.2.1.5 RIC CALL PROCESS ID IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to a Near-RT RIC node and is required for INSERT action. The same information element is used in RIC Control procedure + +Direction: E2 Node → Near-RT RIC (when carried in RIC INDICATION) and Near-RT RIC → E2 Node (when carried in RIC CONTROL REQUEST). + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Call Process ID Format</i> | | | | | +| >E2SM-RC Call Process ID Format 1 | M | | 9.2.1.5.1 | | + +#### 9.2.1.5.1 E2SM-RC Call Process ID Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-----------------------|-----------------------| +| RIC Call Process ID | M | | 9.3.18 | | + +#### 9.2.1.6 RIC CONTROL HEADER IE + +This information element is part of the RIC CONTROL message sent by the Near-RT RIC to an E2 Node and is required for RIC Control Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Control Header Format</i> | M | | | | +| >E2SM-RC Control Header Format 1 | | | 9.2.1.6.1 | | +| >E2SM-RC Control Header Format 2 | | | 9.2.1.6.2 | | +| >E2SM-RC Control Header Format 3 | | | 9.2.1.6.3 | | +| >E2SM-RC Control Header Format 4 | | | 9.2.1.6.4 | | + +#### 9.2.1.6.1 E2SM-RC Control Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|-------------------------------------|-------------------------------------------------------------------------------| +| UE ID | M | | 9.3.10 | | +| RIC Style Type | M | | 9.3.3 | | +| Control Action ID | M | | 9.3.6 | Refer to Clause 7.6 | +| RIC Control decision | O | | ENUMERATED<br>(accept, reject, ...) | Used only when a CONTROL action is sent as a response to an Insert Indication | + +#### 9.2.1.6.2 E2SM-RC Control Header Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|-------------------------------------|-----------------------------------------------------------------------------------------------------------------| +| UE ID | O | | 9.3.10 | | +| RIC Control decision | O | | ENUMERATED<br>(accept, reject, ...) | Used only when RIC Control Request message is sent as a response to the INSERT indication message from E2 Node. | + +### 9.2.1.6.3 E2SM-RC Control Header Format 3 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-----------------------|------------------------------------------------------------------------------| +| UE Group ID | M | | 9.3.54 | To uniquely identify a UE group | +| UE Group Definition | M | | 9.3.56 | RAN parameters defined in Clause 8.1.3 shall be used to define the UE group. | +| RIC Style Type | M | | 9.3.3 | Identifier of the RIC Control Service Style | +| Control Action ID | M | | 9.3.6 | Identifier of the RIC Control Action | + +### 9.2.1.6.4 E2SM-RC Control Header Format 4 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|----------------------------------|-------------------------------------------------------------------------------| +| Partial UE ID | M | | 9.3.57 | | +| RIC Style Type | M | | 9.3.3 | | +| Control Action ID | M | | 9.3.6 | Refer to Clause 7.6 | +| RIC Control decision | O | | ENUMERATED (accept, reject, ...) | Used only when a CONTROL action is sent as a response to an Insert Indication | + +### 9.2.1.7 RIC CONTROL MESSAGE IE + +This information element is part of the RIC CONTROL message sent by the Near-RT RIC to an E2 Node and is required for RIC Control Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> Control Message Format | M | | | | +| >E2SM-RC Control Message Format 1 | | | 9.2.1.7.1 | | +| >E2SM-RC Control Message Format 2 | | | 9.2.1.7.2 | | +| >E2SM-RC Control Message Format 3 | | | 9.2.1.7.3 | | +| >E2SM-RC Control Message Format 4 | | | 9.2.1.7.4 | | +| >E2SM-RC Control Message Format 5 | | | 9.2.1.7.5 | | + +#### 9.2.1.7.1 E2SM-RC Control Message Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|--------------------------------------|-----------------------|------------------------------| +| List of RAN parameters | | 0..<maxnoofAssociate dRANParameters> | | | +| >RAN Parameter ID | M | | 9.3.8 | Refer to table in Clause 8.4 | +| >RAN Parameter Value Type | M | | 9.3.11 | Refer to table in Clause 8.4 | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------------------------------------| +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function for a specific Control action. The value is <65535>. | + +### 9.2.1.7.2 E2SM-RC Control Message Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------------|----------|----------------------------|-----------------------------------------------------|-----------------------| +| Sequence of Control Styles for Multiple Actions | | 1..<maxnoofRICStyles> | | | +| >Indicated Control Style | M | | 9.3.3 | | +| >Sequence of Control Actions | | 1..<maxnoofMulCtrlActions> | | | +| >>Control Action ID | M | | 9.3.6 | Refer to Clause 7.6 | +| >>Control Action Parameters | O | | 9.2.1.7.1<br>E2SM-RC<br>Control Message<br>Format 1 | | + +| Range bound | Explanation | +|-----------------------|------------------------------------------------------------------------------| +| maxnoofRICStyles | Maximum no. of Control Styles supported by RAN Function. The value is <63>. | +| maxnoofMulCtrlActions | Maximum no. of Control actions supported by RAN Function. The value is <63>. | + +## 9.2.1.7.3 E2SM-RC Control Message Format 3 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------------------------|----------|--------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------| +| List of entity filters | | <i>0..<maxnoofAssociatedEntityFilters></i> | | List of entity filters for identifying entities for RAN entity-specific UE group control action | +| >Entity Filter ID | M | | 9.3.55 | Used to uniquely identify an entity filter definition | +| >Entity Filter Definition | M | | 9.3.29 | This IE is used to determine the entities of the UE group, based on the RAN parameters in Clause 8.4.2 and 8.1. | +| >List of RAN control parameters for the matching entities | | <i>1..<maxnoofAssociatedRANParameters></i> | | | +| >>RAN Parameter ID | M | | 9.3.8 | Refer to table in Clause 8.3. This shall not include <i>key flag</i> parameter whose value type is <b>"ELEMENT with Key Flag TRUE"</b> | +| >>RAN Parameter Value Type | M | | 9.3.11 | Refer to table in Clause 8.3. The value type shall not be <b>"ELEMENT with Key Flag TRUE"</b> | +| List of RAN control parameters | | <i>0..<maxnoofAssociatedRANParameters></i> | | List of RAN Entity-agnostic RAN control parameters for control action on the group of UEs | +| >RAN Parameter ID | M | | 9.3.8 | Refer to table in Clause 8.3. This shall not include a <i>key flag</i> parameter, whose value type is <b>"ELEMENT with Key Flag TRUE"</b> | +| >RAN Parameter Value Type | M | | 9.3.11 | Refer to table in Clause 8.3. The value type shall not be <b>"ELEMENT with Key Flag TRUE"</b> | + +| Range bound | Explanation | +|--------------------------------|-----------------------------------------------------------------------------------------------------| +| maxnoofAssociatedEntityFilters | Maximum no. of entity filter definitions for a UE group. The value is <255>. | +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function for a control action. The value is <65535>. | + +### 9.2.1.7.4 E2SM-RC Control Message Format 4 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|--------------------------------------------------|-----------------------|------------------------------------------------------------| +| List of RAN parameters | | <i>0..<maxnoofAssociatedRANParameters></i> | | | +| >RAN Parameter ID | M | | 9.3.8 | Refer to table in clause 8.4 for applicable RAN Parameters | +| >RAN Parameter Definition | O | | 9.3.51 | Refer to clause 7.6.9 for usage of this IE. | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------------------------------------| +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function for a specific Control action. The value is <65535>. | + +### 9.2.1.7.5 E2SM-RC Control Message Format 5 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------|-------------------------| +| null | M | | NULL | Contains no information | + +## 9.2.1.8 RIC CONTROL OUTCOME IE + +This information element is part of the RIC CONTROL ACKNOWLEDGEMENT and RIC CONTROL FAILURE messages and is sent by the E2 Node to the Near-RT RIC and is required for RIC Control Procedure. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Control Outcome Format</i> | M | | | | +| >E2SM-RC Control Outcome Format 1 | | | 9.2.1.8.1 | | +| >E2SM-RC Control Outcome Format 2 | | | 9.2.1.8.2 | | +| >E2SM-RC Control Outcome Format 3 | | | 9.2.1.8.3 | | + +### 9.2.1.8.1 E2SM-RC Control Outcome Format 1 + +The *E2SM-RC Control Outcome* IE Format 1 supports a sequence of RAN Parameters sent as ID/Value pairs. The meaning of the ID/Value pairs is defined in Clause 7.6. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-----------------------------------------------|-----------------------|-----------------------| +| Sequence of RAN Parameters | | <i>0..<maxnoofRANOutcomeParameters></i> | | | +| >RAN Parameter ID | M | | 9.3.8 | | +| >RAN Parameter Value | M | | 9.3.14 | | + +| Range bound | Explanation | +|-----------------------------|-----------------------------------------------| +| maxnoofRANOutcomeParameters | Maximum no. of RAN Parameters. Value is <255> | + +### 9.2.1.8.2 E2SM-RC Control Outcome Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------------|----------|------------------------------------------------|-----------------------|-----------------------| +| Sequence of Control Styles for Multiple Outcomes | | 1.. <i><maxnoofRICStyles></i> | | | +| >Indicated Control Style | M | | 9.3.3 | | +| >Sequence of Control Actions Outcome | | 1.. <i><maxnoofMulCtrlActions></i> | | | +| >>Control Action ID | M | | 9.3.6 | | +| >>Sequence of RAN Parameters | | 1.. <i><maxnoofRANOutcomeParameters></i> | | | +| >>>RAN Parameter ID | M | | 9.3.8 | | +| >>>RAN Parameter Value | M | | 9.3.14 | | + +| Range bound | Explanation | +|-----------------------------|------------------------------------------------------------------------------| +| maxnoofRICStyles | Maximum no. of Control Styles supported by RAN Function. The value is <63>. | +| maxnoofMulCtrlActions | Maximum no. of Control actions supported by RAN Function. The value is <63>. | +| maxnoofRANOutcomeParameters | Maximum no. of RAN Parameters. Value is <255> | + +### 9.2.1.8.3 E2SM-RC Control Outcome Format 3 + +The *E2SM-RC Control Outcome* IE Format 3 supports a sequence of RAN Parameters sent as ID and RAN parameter value types, where each RAN parameter value type is based on the categorization of the parameters into *ELEMENT with Key Value TRUE*, *ELEMENT with Key Value FALSE*, *STRUCTURE* and *LIST*. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|------------------------------------------------|-----------------------|-----------------------| +| Sequence of RAN Parameters | | 0.. <i><maxnoofRANOutcomeParameters></i> | | | +| >RAN Parameter ID | M | | 9.3.8 | | +| >RAN Parameter Value Type | M | | 9.3.11 | | + +| Range bound | Explanation | +|-----------------------------|-----------------------------------------------| +| maxnoofRANOutcomeParameters | Maximum no. of RAN Parameters. Value is <255> | + +### 9.2.1.9 RIC QUERY HEADER IE + +This information element is part of the RIC QUERY REQUEST message sent by the Near-RT RIC to an E2 Node and is required for RIC QUERY Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> Query Header Format | M | | | | +| >E2SM-RC Query Header Format 1 | | | 9.2.1.9.1 | | + +### 9.2.1.9.1 E2SM-RC Query Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|-----------------------|---------------------------------------------------------------------------------------------------------| +| RIC Style Type | M | | 9.3.3 | Indicates Style Types in Clause 7.8.1 | +| Associated E2 Node Info | O | | 9.3.29 | Used to set optional E2 Node related information.<br>RAN Parameters in Clause 8.1.2 shall only be used. | +| Associated UE Info | O | | 9.3.52 | Indicates applicable UE(s) ("Any" UE if not included). | + +### 9.2.1.10 RIC QUERY DEFINITION IE + +This information element is part of the RIC QUERY REQUEST message sent by the Near-RT RIC to an E2 Node and is required for RIC Query Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> Query Definition Format | M | | | | +| >E2SM-RC Query Definition Format 1 | | | 9.2.1.10.1 | | + +#### 9.2.1.10.1 E2SM-RC Query Definition Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|-----------------------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| List of RAN parameters | | 1..<maxnoofAssociate<br>dRANParameters> | | | +| >RAN Parameter ID | M | | 9.3.8 | Refer to table in Clause 8.6 | +| >RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list).<br>If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported.<br>Only the RAN Parameter ID values declared in RAN Function Definition may be included. | + +| Range bound | Explanation | +|--------------------------------|-----------------------------------------------------------------------------------------------------| +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function for Query Definition. The value is <65535>. | + +### 9.2.1.11 RIC QUERY OUTCOME IE + +This information element is part of the RIC QUERY RESPONSE message sent by the Near-RT RIC to an E2 Node and is required for RIC Query Procedure. + +Direction: E2 Node → Near-RT RIC + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> <i>Query Outcome Format</i> | M | | | | +| >E2SM-RC Query Outcome Format 1 | | | 9.2.1.11.1 | | +| >E2SM-RC Query Outcome Format 2 | | | 9.2.1.11.2 | | + +#### 9.2.1.11.1 E2SM-RC Query Outcome Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------|----------|-------------------------------------|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of Cell Information | | 1..<maxnoofCellID> | | | +| >Cell Global ID | M | | 9.3.36 | | +| >List of RAN parameters | | 0..<maxnoofAssociatedRANParameters> | | | +| >> RAN Parameter ID | M | | 9.3.8 | Refer to table in Clause 8.6.1 | +| >> RAN Parameter Value Type | O | | 9.3.11 | Refer to table in Clause 8.6.1 | +| >Neighbour Relation Table | O | | 9.3.38 | Provides information on neighbours of serving cell. This IE shall be reported if RAN Parameter ID is set to “2” as described in Clause 8.6.1. | +| > Serving Cell Config Common | O | | 9.3.60 | Provides information on common parameters of the serving cell. This IE shall be reported if RAN Parameter ID is set to “5” as described in Clause 8.2.3. | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------------------------------------| +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function for Query Outcome. The value is <65535>. | +| maxnoofCellID | Maximum number of Cell Identifiers supported by Query Outcome Format 1 to be reported. The value is <65535>. | + +### 9.2.1.11.2 E2SM-RC Query Outcome Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------|----------|---------------------------------------------------|-----------------------|--------------------------------| +| Sequence of UE Information | | 1.. <i><maxnoofUEID></i> | | | +| >UE ID | M | | 9.3.10 | | +| >List of RAN parameters | | 0.. <i><maxnoofAssociatedRANParameters></i> | | | +| >> RAN Parameter ID | M | | 9.3.8 | Refer to table in Clause 8.6.2 | +| >> RAN Parameter Value Type | O | | 9.3.11 | Refer to table in Clause 8.6.2 | +| >UE Filter ID | O | | 9.3.53 | | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------------------------------------------------| +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function for Query Outcome. The value is <i><65535></i> . | +| maxnoofUEID | Maximum number of UE Identifiers supported by Query Outcome Format 2 to be reported. The value is <i><65535></i> . | + +### 9.2.1.12 Service Layer Cause + +#### 9.2.1.12.1 Service Layer Cause IE + +The purpose of the *Service Layer Cause* IE is to indicate the reason for error handling for the RIC Functional procedures and selected global procedures (Error Indication, E2 Setup, RIC Service Update) + +| IE/Group Name | Presence | Range | IE Type and Reference | Semantics Description | +|---------------------------|----------|-------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| +| Service Layer Cause Group | M | | | | +| >RIC services | | | | | +| >>RIC Request | M | | ENUMERATED (<br>RIC Event Trigger Style Type not supported,<br>RIC Event Trigger Format Type not supported,<br>RAN Parameter ID not supported,<br>Call Process Type ID not supported,<br>Call Process Breakpoint ID not supported,<br>RIC Report Style Type not supported,<br>Supported RIC Event Trigger Style Type no supported,<br>RIC Action Format Type not supported,<br>RIC Indication Header Format Type not supported,<br>RIC Indication Message Format Type not supported,<br>RIC Insert Style Type not supported,<br>Insert Indication ID not supported,<br>RIC Call Process ID Format Type not supported,<br>RIC Control Style Type not supported,<br>Control Action ID not supported,<br>RIC Control Header Format Type not supported,<br>RIC Control Message Format Type not supported,<br>RIC Control Outcome Format Type not supported,<br>RIC Policy Style Type not supported,<br>Policy Action ID not supported,<br>RIC Query Style Type not supported,<br>RIC Query Header Format Type not supported,<br>RIC Query Definition Format Type not supported,<br>RIC Query Outcome Format Type not supported,<br>...<br>) | | +| >Protocol | | | | | +| >>Protocol Cause | M | | ENUMERATED<br>(Transfer Syntax Error,<br>Abstract Syntax Error (Reject),<br>Abstract Syntax Error (Ignore and Notify),<br>Message not Compatible with Receiver State,<br>Semantic Error,<br>Abstract Syntax Error (Falsely Constructed Message),<br>Unspecified, ...) | | + +The meaning of the different cause values is described in the following table. In general, "not supported" cause values indicate that the related capability is missing. On the other hand, "not available" cause values indicate that the related capability is present, but insufficient resources are available to perform the requested action. + +| RIC Request cause | Meaning | +|------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------| +| RIC Event Trigger Style Type not supported | Event Triggering style is not supported and was not declared in RAN Function Definition | +| RIC Event Trigger Format Type not supported | Event Format Type for requested style type is not supported and was not declared in RAN Function Definition | +| RAN Parameter ID not supported | RAN Parameter ID is not supported and was not declared in RAN Function Definition for use with the requested Event Trigger or RIC Service | +| Call Process Type ID not supported | Call Process Type ID is not supported and was not declared in RAN Function Definition | +| Call Process Breakpoint ID not supported | Call Process Breakpoint ID for requested Call Process Type is not supported and was not declared in RAN Function Definition | +| RIC Report Style Type not supported | RIC Report Style Type is not supported and was not declared in RAN Function Definition | +| Supported RIC Event Trigger Style Type not supported | Supported RIC Event Trigger Style Type for requested service and style type is not supported and was not declared in RAN Function Definition | +| RIC Action Format Type not supported | RIC Action Format Type for requested service and style type is not supported and was not declared in RAN Function Definition | +| RIC Indication Header Format Type not supported | RIC Indication Header type for requested service and style type is not supported and was not declared in RAN Function Definition | +| RIC Indication Message Format Type not supported | RIC Indication Message Format Type for requested service and style type is not supported and was not declared in RAN Function Definition | +| RIC Insert Style Type not supported | RIC Insert Style Type is not supported and was not declared in RAN Function Definition | +| Insert Indication ID not supported | Insert Indication ID for the requested style type is not supported and was not declared in RAN Function Definition | +| RIC Call Process ID Format Type not supported | RIC Call Process ID Format Type for requested style type is not supported and was not declared in RAN Function Definition | +| RIC Control Style Type not supported | RIC Control Style Type is not supported and was not declared in RAN Function Definition | +| Control Action ID not supported | Control Action ID for the requested style type is not supported and was not declared in RAN Function Definition | +| RIC Control Header Format Type not supported | RIC Control Header Format Type for requested style type is not supported and was not declared in RAN Function Definition | +| RIC Control Message Format Type not supported | RIC Control Message Format Type is not supported and was not declared in RAN Function Definition | +| RIC Control Outcome Format Type not supported | RIC Control Outcome Format Type for requested style type is not supported and was not declared in RAN Function Definition | +| RIC Policy Style Type not supported | RIC Policy Style Type is not supported and was not declared in RAN Function Definition | +| Policy Action ID not supported | Policy Action ID for requested style type is not supported and was not declared in RAN Function Definition | +| RIC Query Style Type not supported | RIC Query Style Type is not supported and was not declared in RAN Function Definition | +| RIC Query Header Format Type not supported | RIC Query Header type for requested style type is not supported and was not declared in RAN Function Definition | +| RIC Query Definition Format Type not supported | RIC Query Definition type for requested style type is not supported and was not declared in RAN Function Definition | +| RIC Query Outcome Format Type not supported | RIC Query Outcome type for requested style type is not supported and was not declared in RAN Function Definition | + +| Protocol cause | Meaning | +|-----------------------------------------------------|----------------------------------------------------------------------------------------------------------------------| +| Transfer Syntax Error | The received message included a transfer syntax error. | +| Abstract Syntax Error (Reject) | The received message included an abstract syntax error and the concerning criticality indicated "reject". | +| Abstract Syntax Error (Ignore And Notify) | The received message included an abstract syntax error and the concerning criticality indicated "ignore and notify". | +| Message Not Compatible With Receiver State | The received message was not compatible with the receiver state. | +| Semantic Error | The received message included a semantic error. | +| Abstract Syntax Error (Falsely Constructed Message) | The received message contained IEs or IE groups in wrong order or with too many occurrences. | +| Unspecified | Sent when none of the above cause values applies but still the cause is Protocol related. | + +## 9.2.2 Messages for RIC Global Procedures + +### 9.2.2.1 RAN Function Definition IE + +This information element is part of the E2 SETUP REQUEST, and RIC SERVICE UPDATE message sent by the E2 Node to the Near-RT RIC and is used to provide all required information for the Near-RT RIC to determine how a given E2 Node has been configured to support a given RAN Function specific E2SM. + +Direction: E2 Node → NEAR-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------|----------|-------|-----------------------|-----------------------| +| RAN Function Name | M | | 9.3.2 | | +| RAN Function Definition for EVENT TRIGGER | O | | 9.2.2.2 | | +| RAN Function Definition for REPORT | O | | 9.2.2.3 | | +| RAN Function Definition for INSERT | O | | 9.2.2.4 | | +| RAN Function Definition for CONTROL | O | | 9.2.2.5 | | +| RAN Function Definition for POLICY | O | | 9.2.2.6 | | +| RAN Function Definition for QUERY | O | | 9.2.2.7 | | + +## 9.2.2.2 RAN Function Definition for EVENT TRIGGER + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------|----------|---------------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of EVENT TRIGGER styles | | 1..<br><maxnoo<br>fRICStyle<br>s> | | | +| >RIC Event Trigger Style Type | M | | 9.3.3 | | +| >RIC Event Trigger Style Name | M | | 9.3.4 | | +| >RIC Event Trigger Format Type | M | | 9.3.5 | | +| Sequence of RAN Parameters for L2 Variables | | 0..<br><maxnoo<br>fAssociat<br>edRANP<br>arameter<br>s> | | RAN Parameters defined in Clauses 8.1.1.4 and 8.1.1.8. Only included if L2 variables for Event Trigger Style 4 is supported. | +| >RAN Parameter ID | M | | 9.3.8 | | +| >RAN Parameter Name | M | | 9.3.9 | | +| >RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | +| Sequence of Call Process Types | | 0..<br><maxnoo<br>fCallProc<br>essTypes<br>> | | Only included if Event Trigger Style 2 is supported. | +| >Call Process Type ID | M | | 9.3.15 | | +| >Call Process Type Name | M | | 9.3.19 | | +| >Sequence of Call Process Breakpoints | | 1..<br><maxnoo<br>fCallProc<br>essBreak<br>points> | | | +| >>Call Process Breakpoint ID | M | | 9.3.49 | | +| >>Call Process Breakpoint Name | M | | 9.3.50 | | +| >>Sequence of Associated RAN Parameters | | 0..<br><maxnoo<br>fAssociat<br>edRANP<br>arameter<br>s> | | RAN Parameters defined in Clause 8.1.2. Only included if Associated E2 Node Info for Event Trigger style 2 is supported | +| >>>RAN Parameter ID | M | | 9.3.8 | | +| >>>RAN Parameter Name | M | | 9.3.9 | | +| >>>RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | +| Sequence of RAN Parameters for Identifying UEs | | 0..<br><maxnoo | | RAN Parameters defined in Clause 8.1.3. | + +| | | | | | +|--------------------------------------------------|---|--------------------------------------------------|--------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | <i>fAssociatedRANParameters</i> | | Only included if Associated UE Info for any of Event Trigger Styles 1, 2, 4, 5 is supported. | +| >RAN Parameter ID | M | | 9.3.8 | | +| >RAN Parameter Name | M | | 9.3.9 | | +| >RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | +| Sequence of RAN Parameters for Identifying Cells | | <i>0..<maxnoofAssociatedRANParameters></i> | | RAN Parameters defined in Clause 8.1.4. Only included if Associated Cell Info for any of Event Trigger Styles 3, 5 is supported. | +| >RAN Parameter ID | M | | 9.3.8 | | +| >RAN Parameter Name | M | | 9.3.9 | | +| >RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | + +| Range bound | Explanation | +|--------------------------------|------------------------------------------------------------------------------------------| +| maxnoofRICStyles | Maximum no. of styles supported by RAN Function. The value is <63>. | +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function. The value is <65535>. | +| maxnoofCallProcessTypes | Maximum no. of Call Process types supported by RAN Function. The value is <65535>. | +| maxnoofCallProcessBreakpoints | Maximum no. of Call Process breakpoints supported by RAN Function. The value is <65535>. | + +### 9.2.2.3 RAN Function Definition for REPORT + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------|----------|-----------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of REPOT styles | | 1..<br><maxnoof<br>RICStyles<br>> | | | +| >RIC Report Style Type | M | | 9.3.3 | | +| >RIC Report Style Name | M | | 9.3.4 | | +| >Supported RIC Event Trigger Style Type | M | | 9.3.3 | | +| >RIC Report Action Format Type | M | | 9.3.5 | Action Definition type used by Report style | +| >RIC Indication Header Format Type | M | | 9.3.5 | Indication Header type used by Report style | +| >RIC Indication Message Format Type | M | | 9.3.5 | Indication Message type used by Report style | +| >Sequence of RAN Parameters Supported | | 0..<br><maxnoof<br>Associate<br>dRANPara<br>meters> | | Only included if RAN parameters for corresponding Report style are supported. | +| >>RAN Parameter ID | M | | 9.3.8 | RAN Parameter IDs for the corresponding Report Style defined in Clause 7.4. | +| >>RAN Parameter Name | M | | 9.3.9 | RAN Parameter Names for the corresponding Report Style defined in Clause 7.4. | +| >>RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------| +| maxnoofRICstyles | Maximum no. of styles supported by RAN Function. The value is <63>. | +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function. The value is <65535>. | + +## 9.2.2.4 RAN Function Definition for INSERT + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------|----------|-----------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of INSERT styles | | 1..<br><maxnoofRICStyles> | | | +| >RIC Insert Style Type | M | | 9.3.3 | | +| >RIC Insert Style Name | M | | 9.3.4 | | +| >Supported RIC Event Trigger Style Type | M | | 9.3.3 | | +| >RIC Action Definition Format Type | M | | 9.3.5 | | +| >Sequence of Insert Indications | | 0..<br><maxnoofInsertIndication> | | | +| >>Insert Indication ID | M | | 9.3.16 | Refer to Clause 7.5. | +| >>Insert Indication Name | M | | 9.3.17 | Refer to Clause 7.5. | +| >>Sequence of Associated RAN Parameters | | 0..<br><maxnoofAssociatedRANParameters> | | Only included if RAN parameters for corresponding Insert style and Insert indication ID are supported | +| >>>RAN Parameter ID | M | | 9.3.8 | | +| >>>RAN Parameter Name | M | | 9.3.9 | | +| >>>RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | +| >RIC Indication Header Format Type | M | | 9.3.5 | | +| >RIC Indication Message Format Type | M | | 9.3.5 | | +| >RIC Call Process ID Format Type | M | | 9.3.5 | | + +| Range bound | Explanation | +|--------------------------------|-----------------------------------------------------------------------------------| +| maxnoofRICstyles | Maximum no. of styles supported by RAN Function. The value is <63>. | +| maxnoofInsertIndication | Maximum no. of Insert indications supported by RAN Function. The value is <65535> | +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function. The value is <65535>. | + +### 9.2.2.5 RAN Function Definition for CONTROL + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------------------------------------|----------|--------------------------------------------------------|-----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of CONTROL styles | | 1..<br><maxno<br>fRICStyle<br>s> | | | +| >RIC Control Style Type | M | | 9.3.3 | | +| >RIC Control Style Name | M | | 9.3.4 | | +| >Sequence of Control Actions | | 0..<br><maxno<br>fControlA<br>ction> | | | +| >>Control Action ID | M | | 9.3.6 | | +| >>Control Action Name | M | | 9.3.7 | | +| >>Sequence of Associated RAN Parameters | | 0..<br><maxno<br>fAssociat<br>edRANP<br>arameter<br>s> | | Only included if Control message RAN parameters for corresponding Control style and Control Action ID are supported | +| >>>RAN Parameter ID | M | | 9.3.8 | | +| >>>RAN Parameter Name | M | | 9.3.9 | | +| >>>RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | +| >>UE group-based Control action supported | O | | ENUMERATED(true, false,...) | To indicate support of UE group-based control as defined in Clause 7.6. Default is FALSE. | +| >RIC Control Header Format Type | M | | 9.3.5 | | +| >RIC Control Message Format Type | M | | 9.3.5 | | +| >RIC Call Process ID Format Type | O | | | | +| >RIC Control Outcome Format Type | M | | 9.3.5 | | +| >Sequence of Associated RAN Parameters for Control Outcome | | 0..<br><maxno<br>ofRANO<br>utcomeP<br>arameter<br>s> | | Only included if Control Outcome RAN parameters for corresponding Control style are supported | +| >>RAN Parameter ID | M | | 9.3.8 | | +| >>RAN Parameter Name | M | | 9.3.9 | | +| >>RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | +| >List of additional supported Format Types | | 0..<br><maxno<br>ofForma<br>tTypes> | | This IE shall be included if the <i>UE group-based Control action supported</i> IE is set to | + +| | | | | | +|-----------------------------------|---|--|-------|-------------------------------------------------------------------------| +| | | | | "true" or Control Style uses action specific formats. | +| >>RIC Control Header Format Type | M | | 9.3.5 | | +| >>RIC Control Message Format Type | M | | 9.3.5 | | +| >>RIC Control Outcome Format Type | O | | 9.3.5 | | +| >>Control Action ID | O | | 9.3.6 | This IE shall be included if Control Style uses action specific formats | + +| Range bound | Explanation | +|--------------------------------|------------------------------------------------------------------------------------------------| +| maxnoofRICstyles | Maximum no. of styles supported by RAN Function. The value is <63>. | +| maxnoofControlAction | Maximum no. of Control actions supported by RAN Function. The value is <65535>. | +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function. The value is <65535>. | +| maxnoofRANOutcomeParameters | Maximum no. of parameters in RAN Control Outcome supported by RAN Function. The value is <255> | +| maxnoofFormatTypes | Maximum no. of formats supported by a CONTROL service style. The value is <63> | + +## 9.2.2.6 RAN Function Definition for POLICY + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------------------------|----------|-----------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of POLICY styles | | 1..<br><maxnrofRICStyles> | | | +| >RIC Policy Style Type | M | | 9.3.3 | | +| >RIC Policy Style Name | M | | 9.3.4 | | +| >Supported RIC Event Trigger Style Type | M | | 9.3.3 | | +| >Sequence of Policy Actions | | 0..<br><maxnrofPolicyActions> | | | +| >>Policy Action ID | M | | 9.3.6 | | +| >>Policy Action Name | M | | 9.3.7 | | +| >>RIC Action Definition Format Type | M | | 9.3.5 | | +| >>Sequence of Associated RAN Parameters for Policy Action | | 0..<br><maxnrofAssociatedRANParameters> | | Only included if RAN parameters for the Policy action of the corresponding Policy style and Policy Action ID are supported | +| >>>RAN Parameter ID | M | | 9.3.8 | | +| >>>RAN Parameter Name | M | | 9.3.9 | | +| >>>RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | +| >>Sequence of Associated RAN Parameters for Policy Condition | | 0..<br><maxnrofAssociatedRANParameters> | | Only included if RAN parameters for the Policy condition of the corresponding Policy style and Policy Action ID are supported | +| >>>RAN Parameter ID | M | | 9.3.8 | | +| >>>RAN Parameter Name | M | | 9.3.9 | | +| >>>RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------| +| maxnoofRICstyles | Maximum no. of styles supported by RAN Function. The value is <63>. | +| maxnoofPolicyAction | Maximum no. of Policy actions supported by RAN Function. The value is <65535>. | +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function. The value is <65535>. | + +### 9.2.2.7 RAN Function Definition for QUERY + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------|----------|-----------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Sequence of QUERY styles | | 1..<br><maxnoof<br>RICStyles<br>> | | | +| >RIC Query Style Type | M | | 9.3.3 | | +| >RIC Query Style Name | M | | 9.3.4 | | +| >RIC Query Header Format Type | M | | 9.3.5 | Header type used by Query style | +| >RIC Query Definition Format Type | M | | 9.3.5 | Query Definition format type used by Query style | +| >RIC Query Outcome Format Type | M | | 9.3.5 | Query Outcome format type used by Query style | +| >Sequence of RAN Parameters Supported | | 0..<br><maxnoof<br>Associate<br>dRANPara<br>meters> | | Only included if RAN parameters for corresponding Query style are supported. | +| >>RAN Parameter ID | M | | 9.3.8 | RAN Parameter IDs for the corresponding Query Style defined in Clause 7.8. | +| >>RAN Parameter Name | M | | 9.3.9 | RAN Parameter Names for the corresponding Query Style defined in Clause 7.8. | +| >>RAN Parameter Definition | O | | 9.3.51 | To define the parameter along with its constituent parameters, if any (for a structure), and itemized members, if any (for a list). If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the constituent RAN parameters under this RAN Parameter ID are assumed to be supported. | + +| Range bound | Explanation | +|--------------------------------|--------------------------------------------------------------------------------| +| maxnoofRICstyles | Maximum no. of styles supported by RAN Function. The value is <63>. | +| maxnoofAssociatedRANParameters | Maximum no. of RAN parameters supported by RAN Function. The value is <65535>. | + +## 9.3 Information Element definitions + +### 9.3.1 General + +When specifying information elements which are to be represented by bit strings, if not otherwise specifically stated in the semantics description of the concerned IE or elsewhere, the following principle applies with regards to the ordering of bits: + +- The first bit (leftmost bit) contains the most significant bit (MSB); +- The last bit (rightmost bit) contains the least significant bit (LSB); +- When importing bit strings from other specifications, the first bit of the bit string contains the first bit of the concerned information. + +### 9.3.2 RAN Function Name + +This IE is defined in [4] clause 6.2.2.1. + +### 9.3.3 RIC Style Type + +This IE is defined in [4] clause 6.2.2.2. + +### 9.3.4 RIC Style Name + +This IE is defined in [4] clause 6.2.2.3. + +### 9.3.5 RIC Format Type + +This IE is defined in [4] clause 6.2.2.4. + +### 9.3.6 Control Action ID + +This IE uniquely identifies an action of a given RIC Control style. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------|----------|-------|--------------------------|-----------------------| +| Control Action ID | M | | INTEGER (1.. 65535, ...) | | + +### 9.3.7 Control Action Name + +This IE defines the name of a given control action. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-------------------------------------|-----------------------| +| Control Action Name | M | | PrintableString(SIZE(1.. 150, ...)) | | + +### 9.3.8 RAN Parameter ID + +This IE uniquely identifies a specific RAN parameter of a given RIC Control style. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|-------------------------------|-----------------------| +| RAN Parameter ID | M | | INTEGER (1.. 4294967295, ...) | | + +### 9.3.9 RAN Parameter Name + +This IE defines the name of a given RAN parameter. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------|----------|-------|------------------------------------|-----------------------| +| RAN Parameter Name | M | | PrintableString(SIZE(1..150, ...)) | | + +### 9.3.10 UE ID + +This IE is defined in [4] clause 6.2.2.6. + +### 9.3.11 RAN Parameter Value Type + +This IE specifies the RAN parameters controlled by the RIC. The parameters can be individual elements, or structures containing constituent elements or a list of structures. The parameters and their types are given in Clause 8.4. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|-------------|-------|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>CHOICE RAN Parameter Value Type</b> | M | | | A RAN Parameter can either be an ELEMENT or a STRUCTURE or a LIST. | +| <b>>ELEMENT with Key Flag TRUE</b> | | | | If the RAN parameter is singular variable and if it is a key parameter with key flag set to TRUE as in Clause 8. | +| >>RAN Parameter Value | M | | 9.3.14 | This IE must be filled for both INSERT and CONTROL if the key flag is TRUE so as to reference the proper structure within the list. | +| <b>>ELEMENT with Key Flag FALSE</b> | | | | If the RAN parameter is singular variable and if it is NOT a key parameter (key flag set to FALSE). as in Clause 8. | +| >>RAN Parameter Value | C-ifControl | | 9.3.14 | This IE must be filled if this structure is part of a RIC Control Request message; else, if it is part of a RIC Indication message, this IE is optional. | +| <b>>STRUCTURE</b> | | | | If the RAN parameter is a structure, in turn containing a set of RAN parameters. | +| >>RAN Parameter Structure | M | | 9.3.12 | | +| <b>>LIST</b> | | | | If the RAN parameter is a list containing individual items, each of which has an index. | +| >>RAN Parameter List | M | | 9.3.13 | | + +| Condition | Explanation | +|-----------|-----------------------------------------------------------------------------------------------------| +| ifControl | This IE shall be present if it is part of a RIC Control Request message. Otherwise, it is optional. | + +### 9.3.12 RAN Parameter Structure + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------------------------------------------------|-----------------------|-----------------------------------------------------------------------------------------------------| +| Sequence of RAN Parameters | | <i>0..<maxno ofParametersinStructure></i> | | The size must be at least 1 in the case of CONTROL. | +| >RAN Parameter ID | M | | 9.3.8 | | +| >RAN Parameter Value Type | M | | 9.3.11 | Each parameter in the structure can in turn be an individual ELEMENT or another STRUCTURE or a LIST | + +| Range bound | Explanation | +|------------------------------|-------------------------------------------------------------------------------| +| maxnoofParametersinStructure | Maximum no. of RAN parameters supported in a structure. The value is <65535>. | + +### 9.3.13 RAN Parameter List + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|-----------------------------------|-----------------------|----------------------------------------------------| +| List of RAN Parameter Structures | | $0..<max\ noof\ items\ in\ List>$ | | The size must be at least 1 in the case of CONTROL | +| >RAN Parameter ID | M | | 9.3.8 | | +| >RAN Parameter Structure | M | | 9.3.12 | | + +| Range bound | Explanation | +|--------------------|-------------------------------------------------------------------------------| +| maxnoofItemsinList | Maximum no. of RAN parameters supported in a structure. The value is <65535>. | + +### 9.3.14 RAN Parameter Value + +This IE defines the target value type for a RAN parameter ELEMENT. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|-------|-----------------------|-----------------------| +| <b>CHOICE</b> RAN Parameter Value | M | | | | +| >BOOLEAN | | | BOOLEAN | | +| >INTEGER | | | INTEGER | | +| >REAL | | | REAL | | +| >BIT STRING | | | BIT STRING | | +| >OCTET STRING | | | OCTET STRING | | +| >PrintableString | | | PrintableString | | + +### 9.3.15 Call Process Type ID + +This IE uniquely identifies a call Process Type for a call process breakpoint event trigger. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|--------------------------|-----------------------| +| Call Process Type ID | M | | INTEGER (1.. 65535, ...) | | + +### 9.3.16 Insert Indication ID + +This IE uniquely identifies an action of a given RIC Control style. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|--------------------------|-----------------------| +| Insert Indication ID | M | | INTEGER (1.. 65535, ...) | | + +### 9.3.17 Insert Indication Name + +This IE defines the name of a given control action. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-------------------------------------|-----------------------| +| Insert Indication Name | M | | PrintableString(SIZE(1.. 150, ...)) | | + +### 9.3.18 RAN Call Process ID + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------|----------|-------|------------------------------|----------------------------------------------------------------------------------| +| Call Process ID | | | INTEGER (1..4294967295, ...) | To be used to match an INSERT Indication request with a following CONTROL action | + +### 9.3.19 Call Process Type Name + +This IE defines the name of a given call Process Type. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-------------------------------------|-----------------------| +| Call Process Type Name | M | | PrintableString (SIZE(1..150, ...)) | | + +### 9.3.20 Policy Action + +This IE defines the *Policy Action* IE + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------------------------------------|----------------------------------|-------------------------------------------------------------------| +| Policy Action ID | M | | 9.3.6 | Combined with RIC Style to define Policy type | +| Sequence of RAN Parameters | | 0..<maxnoofAssociatedRANParameters> | | | +| >RAN Parameter ID | M | | 9.3.8 | | +| >RAN Parameter Value Type | M | | 9.3.11 | | +| RIC Policy decision | O | | ENUMERATED (accept, reject, ...) | Used to indicate accept or reject a RRM function as Policy Action | + +| Range bound | Explanation | +|--------------------------------|------------------------------------------------------------------------------------------------------| +| maxnoofAssociatedRANParameters | Maximum no. of RAN Parameter types in action definition supported by RAN Function. Value is <65535>. | + +### 9.3.21 Event Trigger Condition ID + +This IE defines an identifier for event trigger conditions configured for a specific Event Trigger style. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------|-------------------------|-----------------------| +| Event Trigger Condition ID | M | | INTEGER (1..65535, ...) | | + +### 9.3.22 Event Trigger ID for UE + +This IE defines an identifier for a specific UE related condition configured for event triggering. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------|----------|-------|-------------------------|-----------------------| +| Event Trigger ID for UE | M | | INTEGER (1..65535, ...) | | + +### 9.3.23 Event Trigger ID for UE Event + +This IE defines an identifier for a specific UE event configured for event triggering. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------|----------|-------|-------------------------|-----------------------| +| Event Trigger ID for UE Event | M | | INTEGER (1..65535, ...) | | + +### 9.3.24 Event Trigger ID for Cell + +This IE defines an identifier for a specific cell related condition configured for event triggering. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|-------|-------------------------|-----------------------| +| Event Trigger ID for Cell | M | | INTEGER (1..65535, ...) | | + +### 9.3.25 Logical OR + +This IE indicates a logical ("and" or "or") connection of the current condition to the next condition in a given sequence of conditions. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-------------------------------|---------------------------------------------------------------------------------------| +| Logical OR | M | | ENUMERATED (true, false, ...) | If set to "true", logical connection to the next condition is "or". Otherwise, "and". | + +### 9.3.26 Event Trigger UE Information + +This IE defines a set of applicable UEs for event triggering. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------|----------|--------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------| +| Sequence of Associated UE Information | | 1..<maxnoofUEInfo> | | | +| >Event Trigger UE ID | M | | 9.3.22 | | +| > <b>CHOICE UE Type</b> | | | | | +| >> <b>Individual UE</b> | | | | | +| >>>UE ID | M | | 9.3.10 | | +| >>>RAN Parameter Testing for Individual UE | O | | 9.3.29 | To test a set of RAN Parameter conditions for a given UE. RAN Parameters defined in Clause 8.1.3 shall be used. | +| >> <b>UE Group</b> | | | | | +| >>>RAN Parameter Testing for UE Group | M | | 9.3.29 | To test a set of RAN Parameter conditions for defining a given UE group RAN Parameters defined in Clause 8.1.3 shall be used. | +| >Logical OR | O | | 9.3.25 | | + +| Range bound | Explanation | +|---------------|------------------------------------------------------------------------------------------------------------------| +| maxnoofUEInfo | Maximum number of UE information in a given E2 node for which event trigger can be defined. The value is <65535> | + +### 9.3.27 Event Trigger Cell Information + +This IE defines a set of applicable cells for event triggering. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------|----------|------------------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------| +| Sequence of Associated Cell Information | | 1.. <i><maxnoofCellInfo></i> | | | +| >Event Trigger Cell ID | M | | 9.3.24 | | +| > <b>CHOICE</b> Cell Type | M | | | | +| >> <b>Individual Cell</b> | | | | | +| >>>Cell Global ID | M | | 9.3.36 | | +| >> <b>Cell Group</b> | | | | | +| >>>RAN Parameter Testing for Cell Group | M | | 9.3.29 | To test a set of RAN Parameter conditions for defining a given Cell group RAN Parameters defined in Clause 8.1.4 shall be used. | +| >Logical OR | O | | 9.3.25 | | + +| Range bound | Explanation | +|-----------------|---------------------------------------------------------------------------------------------------------| +| maxnoofCellInfo | Maximum number of cells in a given E2 node for which event trigger can be defined. The value is <65535> | + +### 9.3.28 Event Trigger UE Event Information + +This IE defines a set of UE events for event triggering. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------|----------|---------------------------------------|-----------------------|--------------------------------------------------| +| Sequence of UE Event for Event Triggering | | 1.. <i><maxnoofUEEventInfo></i> | | | +| >UE Event ID | M | | 9.3.23 | UE Events defined in Clause 8.1.5 shall be used. | +| >Logical OR | O | | 9.3.25 | | + +| Range bound | Explanation | +|--------------------|------------------------------------------------------------------------------------------------------------------------| +| maxnoofUEEventInfo | Maximum number of UE Event information in a given E2 node for which event trigger can be defined. The value is <65535> | + +## 9.3.29 RAN Parameter Conditional Criteria Definition + +This IE defines the generic test conditions based on RAN parameters. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|----------------------------------------|-----------------------|-----------------------| +| Sequence of RAN Parameter Testing | | 1.. <i><maxnoofRANparamTest></i> | | | +| >RAN Parameter Testing | M | | 9.3.30 | | + +| Range bound | Explanation | +|---------------------|------------------------------------------------------| +| maxnoofRANparamTest | Maximum no. of RAN Parameter Testing. Value is <255> | + +## 9.3.30 RAN Parameter Test + +This IE defines a set of test conditions for RAN parameters nested under a given RAN parameter through recursions. Only “ELEMENT” type of RAN parameter with Key Flag set to “False” is tested. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------------|----------|--------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| RAN Parameter ID | M | | 9.3.9 | | +| <b>CHOICE</b> RAN Parameter Type | M | | | A RAN Parameter can either be an ELEMENT or a STRUCTURE or a LIST.<br>An ELEMENT type RAN Parameter is with Key Flag set to either “True” or “False”. | +| <b>>LIST</b> | | | | | +| >>List of RAN Parameter Structures | | 1.. <i><maxno ofItemsinList></i> | | | +| >>>RAN Parameter Testing | M | | 9.3.30 | | +| <b>>STRUCTURE</b> | | | | | +| >>Sequence of RAN Parameters | | 1.. <i><maxno ofParametersinStructure></i> | | | +| >>>RAN Parameter Testing | M | | 9.3.30 | | +| <b>>ELEMENT with Key Flag True</b> | | | | | +| >>RAN Parameter Value | M | | 9.3.14 | | +| <b>>ELEMENT with Key Flag False</b> | | | | | +| >>RAN Parameter Test Condition | M | | 9.3.31 | | +| >>RAN Parameter Value | O | | 9.3.14 | | +| >>Logical OR | O | | 9.3.25 | | + +| Range bound | Explanation | +|------------------------------|-------------------------------------------------------------------------------| +| maxnoofItemsinList | Maximum no. of RAN parameters supported in a structure. The value is <65535>. | +| maxnoofParametersinStructure | Maximum no. of RAN parameters supported in a structure. The value is <65535>. | + +## 9.3.31 RAN Parameter Test Condition + +This IE compares the particular value of a given RAN parameter with the target value. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------------------------|----------|-------|-----------------------------------------------------------------------------------|-----------------------------------------------------------------| +| <b>CHOICE</b> <i>RAN Parameter Test Condition</i> | | | | | +| >Comparison | M | | ENUMERATED (equal, difference, greaterthan, lessthan, contains, starts with, ...) | Applies only when RAN Parameter Value is present in 9.3.30. | +| >Presence | M | | ENUMERATED (present, configured, rollover, non-zero, ..., value-change) | Applies only when RAN Parameter Value is not present in 9.3.30. | + +For the choice type of “Comparison”, the test condition is Value (*RAN Parameter ID*) (*RAN Parameter Test Condition*) (*RAN Parameter Value*). + +| RAN Parameter Test condition | Test condition | +|------------------------------|-----------------------------------------------------------------------------| +| Equal | Value (RAN Parameter ID) = (RAN Parameter Value) | +| Difference | Value (RAN Parameter ID) <> (RAN Parameter Value) | +| Greaterthan | Value (RAN Parameter ID) => (RAN Parameter Value) | +| lessthan | Value (RAN Parameter ID) < (RAN Parameter Value) | +| contains | Value (RAN Parameter ID) contains (RAN Parameter Value) | +| Starts with | Value (RAN Parameter ID) has the same initial part as (RAN Parameter Value) | + +For the choice type of “Presence”, the test condition is applied to Value (*RAN Parameter ID*) + +| RAN Parameter Test condition | Test condition | +|------------------------------|-------------------------------------------------------------| +| present | Value (RAN Parameter ID) is defined (i.e. memory allocated) | +| configured | Value (RAN Parameter ID) has been set (i.e. not NULL) | +| rollover | Value (RAN Parameter ID) was max defined value and now 0 | +| non-zero | Value (RAN Parameter ID) <> 0 | +| | Length (Value (RAN Parameter ID)) > 0 | + +## 9.3.32 Network Interface Type + +This IE is defined in [4] clause 6.2.2.10. + +## 9.3.33 Network Interface Identifier + +This IE is defined in [4] clause 6.2.2.11. + +## 9.3.34 Network Interface Message ID + +This IE is defined in [4] clause 6.2.2.12. + +## 9.3.35 RRC Message ID + +This IE is defined in [4] clause 6.2.2.13. + +## 9.3.36 Cell Global ID + +This IE is defined in [4] clause 6.2.2.5. + +### 9.3.37 RRC State + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-----------------------------------------------------------------------|-----------------------------------------------------------------------------------------| +| RRC State | M | | ENUMERATED<br>(RRC_Connected,<br>RRC_Inactive,<br>RRC_Idle, Any, ...) | Value 'any' indicates<br>RRC state shall be<br>any of the values in<br>the enumeration. | + +### 9.3.38 Neighbour Relation Information + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------|----------|-----------------------------------------|-------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Serving Cell PCI | M | | 9.3.39 | | +| Serving Cell ARFCN | M | | 9.3.40 | DL Frequency Info for FDD Mode. | +| Neighbour Cell List | | 1.. <i><maxnoofNeighbourCell></i> | | | +| > <b>CHOICE</b> <i>RAN Type</i> | M | | | | +| >> <b>NR</b> | M | | | | +| >>>NR CGI | M | | 9.3.41 | | +| >>>NR PCI | M | | 9.3.42 | | +| >>>5GS TAC | M | | 9.3.43 | | +| >>>NR Mode Info | M | | ENUMERATED (fdd, tdd, ...) | | +| >>>NR Frequency Info | M | | 9.3.44 | DL Frequency Info for FDD Mode.<br>NR Frequency Info IE in TS 38.473 9.3.1.17 | +| >>>Xn X2 Established | M | | ENUMERATED (true, false, ...) | Value "true" shall indicate that Xn or X2 Interface Setup with the neighbour is successful. | +| >>>HO Validated | M | | ENUMERATED (true, false, ...) | Value "true" if at least one successful HO is executed with the neighbour. | +| >>>Version | M | | INTEGER (1..65535, ...) | For every neighbour information, the value is incremented by 1. When there is a change in the existing neighbour information, a new incremented version number is used. The deleted neighbours are not sent. | +| >> <b>E-UTRA</b> | M | | | | +| >>>E-UTRA CGI | M | | 9.3.45 | | +| >>>E-UTRA PCI | M | | 9.3.46 | | +| >>>E-UTRA ARFCN | M | | 9.3.47 | | +| >>>E-UTRA TAC | M | | 9.3.48 | | +| >>>Xn X2 Established | M | | ENUMERATED (true, false, ...) | Value "true" shall indicate that Xn or X2 Interface Setup with the neighbour is successful. | +| >>>HO Validated | M | | ENUMERATED (true, false, ...) | Value "true" if at least one successful HO is executed with this neighbour. | +| >>>Version | M | | INTEGER (1..65535, ...) | For every neighbour information, the value is incremented by 1. When there is a change in the existing neighbour information, a new incremented version number is used. The deleted neighbours are not sent. | + +| Range bound | Explanation | +|----------------------|-----------------------------------------------------------------------------------| +| maxnoofNeighbourCell | Maximum no. of Neighbour Cell information per Serving cell. The value is <65535>. | + +### 9.3.39 Serving Cell PCI + +This IE is defined in [4] clause 6.2.2.14. + +### 9.3.40 Serving Cell ARFCN + +This IE is defined in [4] clause 6.2.2.15. + +### 9.3.41 NR CGI + +This IE is defined in [4] clause 6.2.3.7. + +### 9.3.42 NR PCI + +This IE is defined in [4] clause 6.2.3.29. + +### 9.3.43 NR TAC + +This IE is defined in [4] clause 6.2.3.31. + +### 9.3.44 NR Frequency Info + +This IE is defined in [4] clause 6.2.3.36. + +### 9.3.45 E-UTRA CGI + +This IE is defined in [4] clause 6.2.3.11. + +### 9.3.46 E-UTRA PCI + +This IE is defined in [4] clause 6.2.3.32. + +### 9.3.47 E-UTRA TAC + +This IE is defined in [4] clause 6.2.3.34. + +### 9.3.48 E-UTRA ARFCN + +This IE is defined in [4] clause 6.2.3.33. + +### 9.3.49 Call Process Breakpoint ID + +This IE uniquely identifies a call Process breakpoint for a given call process type. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------|--------------------------|-----------------------| +| Call Process Breakpoint ID | M | | INTEGER (1.. 65535, ...) | | + +## 9.3.50 Call Process Breakpoint Name + +This IE defines the name of a given call Process breakpoint. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------|----------|-------|-------------------------------------|-----------------------| +| Call Process Breakpoint Name | M | | PrintableString (SIZE(1..150, ...)) | | + +## 9.3.51 RAN Parameter Definition + +This IE specifies the definition of a RAN parameter that can be controlled by the RIC when the RAN parameter is of a STRUCTURE type or a LIST type. The parameters and their types are given in Clause 8. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|------------------------------------|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>CHOICE</b> RAN Parameter Type | M | | | A RAN Parameter can either be a LIST or a STRUCTURE. | +| <b>>LIST</b> | | | | | +| >>List of RAN Parameter | | 1..<max noofItemsinList> | | | +| >>>RAN Parameter ID | M | | 9.3.8 | | +| >>>RAN Parameter Name | M | | 9.3.9 | This IE shall be ignored when included in a RIC Functional Procedure message. | +| >>>RAN Parameter Definition | O | | 9.3.51 | If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the itemized RAN parameters under this RAN Parameter ID are assumed to be supported.<br><br>Shall not be included If the RAN Parameter ID is of an ELEMENT type. | +| <b>>STRUCTURE</b> | | | | | +| >>Sequence of RAN Parameters | | 1..<max noofParametersinStructure> | | | +| >>>RAN Parameter ID | M | | 9.3.8 | | +| >>>RAN Parameter Name | M | | 9.3.9 | This IE shall be ignored when included in a RIC Functional Procedure message. | +| >>>RAN Parameter Definition | O | | 9.3.51 | If not included for the RAN Parameter ID of a STRUCTURE type or a LIST type, then all the itemized RAN parameters under this RAN Parameter ID are assumed to be supported.<br><br>Shall not be included If the RAN Parameter ID is of an ELEMENT type. | + +| Range bound | Explanation | +|------------------------------|-------------------------------------------------------------------------------| +| maxnoofItemsinList | Maximum no. of RAN parameters supported in a list. The value is <65535>. | +| maxnoofParametersinStructure | Maximum no. of RAN parameters supported in a structure. The value is <65535>. | + +## 9.3.52 Associated UE Information + +This IE defines a set of applicable UEs for Query Service. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------|----------|--------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------| +| Sequence of Associated UE Information | | 1..<maxnoofUEInfo> | | | +| >UE Filter ID | M | | 9.3.53 | | +| >CHOICE UE Type | | | | | +| >>Individual UE | | | | | +| >>>UE ID | M | | 9.3.10 | | +| >>>RAN Parameter Testing for Individual UE | O | | 9.3.29 | To test a set of RAN Parameter conditions for a given UE. RAN Parameters defined in Clause 8.1.3 shall be used. | +| >>UE Group | | | | | +| >>>RAN Parameter Testing for UE Group | M | | 9.3.29 | To test a set of RAN Parameter conditions for defining a given UE group RAN Parameters defined in Clause 8.1.3 shall be used. | +| >>UE Query | | | | | +| >>>Partial UE ID | M | | 9.3.57 | | +| >>>RAN Parameter Testing | O | | 9.3.29 | To test a set of RAN Parameter conditions for a UE. RAN Parameters defined in Clause 8.1.3 shall be used. | +| >Logical OR | O | | 9.3.25 | | + +| Range bound | Explanation | +|---------------|----------------------------------------------------------------------------------------------------| +| maxnoofUEInfo | Maximum number of UE information in a given E2 node for UE filter conditions. The value is <65535> | + +## 9.3.53 UE Filter ID + +This IE defines an identifier for UE Filter Conditions. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-------------------------|-----------------------| +| UE Filter ID | M | | INTEGER (1..65535, ...) | | + +## 9.3.54 UE Group ID + +This IE defines an identifier to uniquely identify a UE group. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------|----------|-------|-------------------------|-----------------------| +| UE group ID | M | | INTEGER (1..65535, ...) | | + +## 9.3.55 Entity Filter ID + +This IE defines an identifier to uniquely identify an entity filter that defines the set of entities across the UEs in a UE group. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-------|-----------------------|-----------------------| +| Entity Filter ID | M | | INTEGER (1..255, ...) | | + +### 9.3.56 UE Group Definition + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------|----------|---------------------------------------------|------------------------|-----------------------------------------------------| +| List of identifiers to define the UE group | | 1 | | | +| >Identifier Item IEs | | 1..<maxGroupDefinitionIdentifierParameters> | | | +| >>RAN Parameter ID | M | | 9.3.8 | Only RAN Parameters from Clause 8.1.3 shall be used | +| >>RAN Parameter Value Type | M | | 9.3.11 | | +| >>Logical OR | O | | ENUMERATED (true, ...) | Default is FALSE | + +| Range bound | Explanation | +|----------------------------------------|------------------------------------------------------------------------------------------------| +| maxGroupDefinitionIdentifierParameters | Maximum no. of RAN parameters used to determine a logical grouping of UEs. The value is <255>. | + +### 9.3.57 Partial UE ID + +This IE is defined in [4] clause 6.2.2.18. + +### 9.3.58 Policy Condition ID + +This IE defines an identifier for Policy Condition ID. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------|----------|-------|-----------------------|-----------------------| +| Policy Condition ID | M | | INTEGER (0..65535) | | + +### 9.3.59 PLMN Identity + +This IE is defined in [4] clause 6.2.3.1. + +### 9.3.60 Serving Cell Configuration Common + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|------------------------------------------------------|---------------------------------------------------------------------| +| SSB Positions in Burst | M | | OCTET STRING | <i>ssb-PositionsInBurst</i> IE in TS 38.331 [22] Clause 6.3.2 | +| SSB Periodicity | M | | ENUMERATED {ms5, ms10, ms20, ms40, ms80, ms160, ...} | <i>ssb-periodicityServingCell</i> IE in TS 38.331 [22] Clause 6.3.2 | + +| | | | | | +|------------------------|---|--|----------------------------------------------------------------------------------------------------|---------------------------------------------------------------------| +| SSB Subcarrier Spacing | M | | ENUMERATED<br>{kHz15, kHz30,<br>kHz60, kHz120,<br>kHz240, kHz480-<br>v1700, kHz960-<br>v1700, ...} | <i>ssbSubcarrierSpacing</i><br>IE in TS 38.331 [22]<br>Clause 6.3.2 | +|------------------------|---|--|----------------------------------------------------------------------------------------------------|---------------------------------------------------------------------| + +## 9.4 Information Element Abstract Syntax (with ASN.1) + +### 9.4.1 General + +E2SM-RC ASN.1 definition conforms to ITU-T Rec. X.680 [5] and ITU-T Rec. X.681 [6]. + +Sub clause 9.4.2 presents the Abstract Syntax of the E2SM information elements to be carried within the E2AP [3] protocol messages with ASN.1. In case there is contradiction between the ASN.1 definition in this sub clause and the tabular format in sub clause 9.2 and 9.3, the ASN.1 shall take precedence, except for the definition of conditions for the presence of conditional elements, in which the tabular format shall take precedence. + +If an E2SM information element carried as an OCTET STRING in an E2AP [3] message that is not constructed as defined above is received, this shall be considered as Abstract Syntax Error, and the message shall be handled as defined for Abstract Syntax Error in clause 9. + +### 9.4.2 Information Element Definitions + +``` +-- ASN1START +-- ***** +-- E2SM-RC Information Element Definitions +-- ***** + +E2SM-RC-IEs { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) oran(53148) e2(1) +version1(1) e2sm(2) e2sm-RC-IEs (3)} + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +-- ***** +-- E2SM Common IEs +-- ***** + +IMPORTS + CGI, + E-UTRA-ARFCN, + EUTRA-CGI, + E-UTRA-PCI, + E-UTRA-TAC, + FiveGS-TAC, + InterfaceIdentifier, + InterfaceType, + Interface-MessageID, + NRFrequencyInfo, + NR-CGI, + NR-PCI, + PartialUEID, + RANfunction-Name, + RIC-Format-Type, + RIC-Style-Name, + RIC-Style-Type, + RRC-MessageID, + ServingCell-ARFCN, + ServingCell-PCI, + UEID +FROM E2SM-COMMON-IEs; +``` + +``` +-- ***** +-- CONSTANTS +-- ***** +``` + +``` +maxnoofMessages INTEGER ::= 65535 +maxnoofE2InfoChanges INTEGER ::= 65535 +maxnoofUEInfoChanges INTEGER ::= 65535 +maxnoofRRCState INTEGER ::= 8 +maxnoofParametersToReport INTEGER ::= 65535 +maxnoofPolicyConditions INTEGER ::= 65535 +maxnoofAssociatedRANParameters INTEGER ::= 65535 +maxnoofUEID INTEGER ::= 65535 +maxnoofCellID INTEGER ::= 65535 +maxnoofRANOutcomeParameters INTEGER ::= 255 +maxnoofParametersInStructure INTEGER ::= 65535 +maxnoofItemsInList INTEGER ::= 65535 +maxnoofUEInfo INTEGER ::= 65535 +maxnoofCellInfo INTEGER ::= 65535 +maxnoofUEEventInfo INTEGER ::= 65535 +maxnoofRANparamTest INTEGER ::= 255 +maxnoofNeighbourCell INTEGER ::= 65535 +maxnoofRICStyles INTEGER ::= 63 +maxnoofCallProcessTypes INTEGER ::= 65535 +maxnoofCallProcessBreakpoints INTEGER ::= 65535 +maxnoofInsertIndication INTEGER ::= 65535 +maxnoofControlAction INTEGER ::= 65535 +maxnoofPolicyAction INTEGER ::= 65535 +maxnoofInsertIndicationActions INTEGER ::= 63 +maxnoofMulCtrlActions INTEGER ::= 63 +maxGroupDefinitionIdentifierParameters INTEGER ::= 255 +maxnoofAssociatedEntityFilters INTEGER ::= 255 +maxnoofFormatTypes INTEGER ::= 63 +``` + +``` +-- ***** +-- IEs +-- ***** +``` + +``` +LogicalOR ::= ENUMERATED {true, false, ...} +``` + +``` +NeighbourCell-List ::= SEQUENCE (SIZE(1..maxnoofNeighbourCell)) OF NeighbourCell-Item +``` + +``` +NeighbourCell-Item ::= CHOICE { + ranType-Choice-NR NeighbourCell-Item-Choice-NR, + ranType-Choice-EUTRA NeighbourCell-Item-Choice-E-UTRA, + ... +} +``` + +``` +NeighbourCell-Item-Choice-NR ::= SEQUENCE { + nR-CGI NR-CGI, + nR-PCI NR-PCI, + fiveGS-TAC FiveGS-TAC, + nR-mode-info ENUMERATED {fdd, tdd, ...}, + nR-FreqInfo NRFrequencyInfo, + x2-Xn-established ENUMERATED {true, false, ...}, + hO-validated ENUMERATED {true, false, ...}, + version INTEGER (1..65535, ...), + ... +} +``` + +``` +NeighbourCell-Item-Choice-E-UTRA ::= SEQUENCE { + eUTRA-CGI EUTRA-CGI, + eUTRA-PCI E-UTRA-PCI, + eUTRA-ARFCN E-UTRA-ARFCN, + eUTRA-TAC E-UTRA-TAC, + x2-Xn-established ENUMERATED {true, false, ...}, + hO-validated ENUMERATED {true, false, ...}, + version INTEGER (1..65535, ...), + ... +} +``` + +``` +NeighbourRelation-Info ::= SEQUENCE { + servingCellPCI ServingCell-PCI, + servingCellARFCN ServingCell-ARFCN, + neighbourCell-List NeighbourCell-List, + ... +} +``` + +``` + +} + +RRC-State ::= ENUMERATED {rrc-connected, rrc-inactive, rrc-idle, any, ...} + +----- +-- Event Trigger related IEs +----- + +EventTrigger-Cell-Info ::= SEQUENCE { +cellInfo-List SEQUENCE (SIZE(1..maxnoofCellInfo)) OF EventTrigger-Cell-Info- +Item, + ... +} + +EventTrigger-Cell-Info-Item ::= SEQUENCE { + eventTriggerCellID RIC-EventTrigger-Cell-ID, + cellType CHOICE { + cellType-Choice-Individual EventTrigger-Cell-Info-Item-Choice-Individual, + cellType-Choice-Group EventTrigger-Cell-Info-Item-Choice-Group, + ... + }, + logicalOR LogicalOR OPTIONAL, + ... +} + +EventTrigger-Cell-Info-Item-Choice-Individual ::= SEQUENCE { + cellGlobalID CGI, + ... +} + +EventTrigger-Cell-Info-Item-Choice-Group ::= SEQUENCE { + ranParameterTesting RANParameter-Testing, + ... +} + +EventTrigger-UE-Info ::= SEQUENCE { +ueInfo-List SEQUENCE (SIZE(1..maxnoofUEInfo)) OF EventTrigger-UE-Info-Item, + ... +} + +EventTrigger-UE-Info-Item ::= SEQUENCE { + eventTriggerUEID RIC-EventTrigger-UE-ID, + ueType CHOICE { + ueType-Choice-Individual EventTrigger-UE-Info-Item-Choice-Individual, + ueType-Choice-Group EventTrigger-UE-Info-Item-Choice-Group, + ... + }, + logicalOR LogicalOR OPTIONAL, + ... +} + +EventTrigger-UE-Info-Item-Choice-Individual ::= SEQUENCE { + ueID UEID, + ranParameterTesting RANParameter-Testing OPTIONAL, + ... +} + +EventTrigger-UE-Info-Item-Choice-Group ::= SEQUENCE { + ranParameterTesting RANParameter-Testing, + ... +} + +EventTrigger-UEevent-Info ::= SEQUENCE { +ueEvent-List SEQUENCE (SIZE(1..maxnoofUEeventInfo)) OF EventTrigger-UEevent- +Info-Item, + ... +} + +EventTrigger-UEevent-Info-Item ::= SEQUENCE { + ueEventID RIC-EventTrigger-UEevent-ID, + logicalOR LogicalOR OPTIONAL, + ... +} + +``` + +``` + +} + +----- +-- RAN Parameter related IEs +----- + +RANParameter-ID ::= INTEGER (1..4294967295, ...) + +RANParameter-Name ::= PrintableString (SIZE(1..150, ...)) + +RANParameter-Definition ::= SEQUENCE { + ranParameter-Definition-Choice RANParameter-Definition-Choice, + ... +} + +RANParameter-Definition-Choice ::= CHOICE { + choiceLIST RANParameter-Definition-Choice-LIST, + choiceSTRUCTURE RANParameter-Definition-Choice-STRUCTURE, + ... +} + +RANParameter-Definition-Choice-LIST ::= SEQUENCE { + ranParameter-List SEQUENCE (SIZE(1..maxnoofItemsinList)) OF RANParameter- +Definition-Choice-LIST-Item, + ... +} + +RANParameter-Definition-Choice-LIST-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ranParameter-Definition RANParameter-Definition OPTIONAL, + ... +} + +RANParameter-Definition-Choice-STRUCTURE ::= SEQUENCE { + ranParameter-STRUCTURE SEQUENCE (SIZE(1..maxnoofParametersinStructure)) OF +RANParameter-Definition-Choice-STRUCTURE-Item, + ... +} + +RANParameter-Definition-Choice-STRUCTURE-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ranParameter-Definition RANParameter-Definition OPTIONAL, + ... +} + +RANParameter-Value ::= CHOICE { + valueBoolean BOOLEAN, + valueInt INTEGER, + valueReal REAL, + valueBits BIT STRING, + valueOctS OCTET STRING, + valuePrintableString PrintableString, + ... +} + +RANParameter-ValueType ::= CHOICE { + ranP-Choice-ElementTrue RANParameter-ValueType-Choice-ElementTrue, + ranP-Choice-ElementFalse RANParameter-ValueType-Choice-ElementFalse, + ranP-Choice-Structure RANParameter-ValueType-Choice-Structure, + ranP-Choice-List RANParameter-ValueType-Choice-List, + ... +} + +RANParameter-ValueType-Choice-ElementTrue ::= SEQUENCE { + ranParameter-value RANParameter-Value, + ... +} + +RANParameter-ValueType-Choice-ElementFalse ::= SEQUENCE { + ranParameter-value RANParameter-Value OPTIONAL, + -- C-ifControl: This IE shall be present if it is part of a RIC Control Request message. Otherwise + it is optional. + +``` + +``` + +} +... +RANParameter-ValueType-Choice-Structure ::= SEQUENCE { + ranParameter-Structure RANParameter-STRUCTURE, + ... +} + +RANParameter-ValueType-Choice-List ::= SEQUENCE { + ranParameter-List RANParameter-LIST, + ... +} + +RANParameter-STRUCTURE ::= SEQUENCE { + sequence-of-ranParameters SEQUENCE (SIZE(1..maxnoofParametersinStructure)) OF +RANParameter-STRUCTURE-Item OPTIONAL, + ... +} + +RANParameter-STRUCTURE-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + ... +} + +RANParameter-LIST ::= SEQUENCE { + list-of-ranParameter SEQUENCE (SIZE(1..maxnoofItemsinList)) OF RANParameter- +STRUCTURE, + ... +} + +RANParameter-Testing ::= SEQUENCE (SIZE(1..maxnoofRANparamTest)) OF RANParameter-Testing-Item + +RANParameter-TestingCondition ::= CHOICE { + ranP-Choice-comparison ENUMERATED {equal, difference, greaterthan, lessthan, +contains, starts-with, ...}, + ranP-Choice-presence ENUMERATED {present, configured, rollover, non-zero, ..., +value-change}, + ... +} + +RANParameter-Testing-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-Type CHOICE { + ranP-Choice-List RANParameter-Testing-Item-Choice-List, + ranP-Choice-Structure RANParameter-Testing-Item-Choice-Structure, + ranP-Choice-ElementTrue RANParameter-Testing-Item-Choice-ElementTrue, + ranP-Choice-ElementFalse RANParameter-Testing-Item-Choice-ElementFalse, + ... + }, + ... +} + +RANParameter-Testing-Item-Choice-List ::= SEQUENCE { + ranParameter-List RANParameter-Testing-LIST, + ... +} + +RANParameter-Testing-Item-Choice-Structure ::= SEQUENCE { + ranParameter-Structure RANParameter-Testing-STRUCTURE, + ... +} + +RANParameter-Testing-Item-Choice-ElementTrue ::= SEQUENCE { + ranParameter-value RANParameter-Value, + ... +} + +RANParameter-Testing-Item-Choice-ElementFalse ::= SEQUENCE { + ranParameter-TestCondition RANParameter-TestingCondition, + ranParameter-Value RANParameter-Value OPTIONAL, + logicalOR LogicalOR OPTIONAL, + ... +} + +``` + +``` + +RANParameter-Testing-LIST ::= SEQUENCE (SIZE(1..maxnoofItemsinList)) OF RANParameter-Testing-Item + +RANParameter-Testing-STRUCTURE ::= SEQUENCE (SIZE(1..maxnoofParametersinStructure)) OF RANParameter-Testing-Item + +UE-Group-Definition ::= SEQUENCE { + ueGroupDefinitionIdentifier-LIST SEQUENCE (SIZE(1..maxGroupDefinitionIdentifierParameters)) OF UEGroupDefinitionIdentifier-Item, + ... +} + +UEGroupDefinitionIdentifier-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + logicalOR LogicalOR OPTIONAL, + ... +} + + +-- RIC Service related IEs + + +RAN-CallProcess-ID ::= INTEGER (1..4294967295, ...) + +RIC-CallProcessType-ID ::= INTEGER (1..65535, ...) + +RIC-CallProcessType-Name ::= PrintableString (SIZE(1..150, ...)) + +RIC-CallProcessBreakpoint-ID ::= INTEGER (1..65535, ...) + +RIC-CallProcessBreakpoint-Name ::= PrintableString (SIZE(1..150, ...)) + +RIC-ControlAction-ID ::= INTEGER (1..65535, ...) + +RIC-ControlAction-Name ::= PrintableString (SIZE(1..150, ...)) + +RIC-EventTriggerCondition-ID ::= INTEGER (1..65535, ...) + +RIC-EventTrigger-UE-ID ::= INTEGER (1..65535, ...) + +RIC-EventTrigger-UEevent-ID ::= INTEGER (1..65535, ...) + +RIC-EventTrigger-Cell-ID ::= INTEGER (1..65535, ...) + +RIC-InsertIndication-ID ::= INTEGER (1..65535, ...) + +RIC-InsertIndication-Name ::= PrintableString (SIZE(1..150, ...)) + +UE-Group-ID ::= INTEGER (1..65535, ...) + +EntityFilter-ID ::= INTEGER (1..255, ...) + +Ric-PolicyConditionID ::= INTEGER (0..65535) + +RIC-PolicyAction ::= SEQUENCE { + ric-PolicyAction-ID RIC-ControlAction-ID, + ranParameters-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF RIC-PolicyAction-RANParameter-Item OPTIONAL, + ..., + ric-PolicyDecision ENUMERATED {accept, reject, ...} OPTIONAL +} + +RIC-PolicyAction-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + ... +} + +UE-Filter-ID ::= INTEGER (1..65535, ...) + +Associated-UE-Info ::= SEQUENCE { + associatedUEInfo-List SEQUENCE (SIZE(1..maxnoofUEInfo)) OF Associated-UE-Info-Item, + +``` + +``` + +... +} + +Associated-UE-Info-Item ::= SEQUENCE { + ueFilterID UE-Filter-ID, + ueType CHOICE { + ueType-Choice-Individual EventTrigger-UE-Info-Item-Choice-Individual, + ueType-Choice-Group EventTrigger-UE-Info-Item-Choice-Group, + ..., + ueQuery UEQuery + }, + logicalOR LogicalOR OPTIONAL, + ... +} + +UEQuery ::= SEQUENCE { + partialUEID PartialUEID, + ranParameterTesting RANParameter-Testing OPTIONAL, + ... +} + +-- ***** +-- E2SM-RC Service Model IEs +-- ***** + +-- ***** +-- Event Trigger OCTET STRING contents +-- ***** + +E2SM-RC-EventTrigger ::= SEQUENCE { + ric-eventTrigger-formats CHOICE { + eventTrigger-Format1 E2SM-RC-EventTrigger-Format1, + eventTrigger-Format2 E2SM-RC-EventTrigger-Format2, + eventTrigger-Format3 E2SM-RC-EventTrigger-Format3, + eventTrigger-Format4 E2SM-RC-EventTrigger-Format4, + eventTrigger-Format5 NULL, + ..., + }, + ... +} + +E2SM-RC-EventTrigger-Format1 ::= SEQUENCE { + message-List SEQUENCE (SIZE(1..maxnoofMessages)) OF E2SM-RC- +EventTrigger-Format1-Item, + globalAssociatedUEInfo EventTrigger-UE-Info OPTIONAL, + ... +} + +E2SM-RC-EventTrigger-Format1-Item ::= SEQUENCE { + ric-eventTriggerCondition-ID RIC-EventTriggerCondition-ID, + messageType MessageType-Choice, + messageDirection ENUMERATED {incoming, outgoing, ...} OPTIONAL, + associatedUEInfo EventTrigger-UE-Info OPTIONAL, + associatedUEEvent EventTrigger-UEEvent-Info OPTIONAL, + logicalOR LogicalOR OPTIONAL, + ... +} + +MessageType-Choice ::= CHOICE { + messageType-Choice-NI MessageType-Choice-NI, + messageType-Choice-RRC MessageType-Choice-RRC, + ... +} + +MessageType-Choice-NI ::= SEQUENCE { + nI-Type InterfaceType, + nI-Identifier InterfaceIdentifier OPTIONAL, + nI-Message Interface-MessageID OPTIONAL, + ... +} + +MessageType-Choice-RRC ::= SEQUENCE { + rRC-Message RRC-MessageID, + ... +} + +``` + +} + +``` + +E2SM-RC-EventTrigger-Format2 ::= SEQUENCE { + ric-callProcessType-ID RIC-CallProcessType-ID, + ric-callProcessBreakpoint-ID RIC-CallProcessBreakpoint-ID, + associatedE2NodeInfo RANParameter-Testing OPTIONAL, + associatedUEInfo EventTrigger-UE-Info OPTIONAL, + ... +} + +``` + +``` + +E2SM-RC-EventTrigger-Format3 ::= SEQUENCE { + e2NodeInfoChange-List SEQUENCE (SIZE(1..maxnoofE2InfoChanges)) OF E2SM-RC- +EventTrigger-Format3-Item, + ... +} + +``` + +``` + +E2SM-RC-EventTrigger-Format3-Item ::= SEQUENCE { + ric-eventTriggerCondition-ID RIC-EventTriggerCondition-ID, + e2NodeInfoChange-ID INTEGER (1..512, ...), + associatedCellInfo EventTrigger-Cell-Info OPTIONAL, + logicalOR LogicalOR OPTIONAL, + ... +} + +``` + +``` + +E2SM-RC-EventTrigger-Format4 ::= SEQUENCE { + ueInfoChange-List SEQUENCE (SIZE(1..maxnoofUEInfoChanges)) OF E2SM-RC- +EventTrigger-Format4-Item, + ... +} + +``` + +``` + +E2SM-RC-EventTrigger-Format4-Item ::= SEQUENCE { + ric-eventTriggerCondition-ID RIC-EventTriggerCondition-ID, + triggerType TriggerType-Choice, + associatedUEInfo EventTrigger-UE-Info OPTIONAL, + logicalOR LogicalOR OPTIONAL, + ... +} + +``` + +``` + +TriggerType-Choice ::= CHOICE { + triggerType-Choice-RRCstate TriggerType-Choice-RRCstate, + triggerType-Choice-UEID TriggerType-Choice-UEID, + triggerType-Choice-L2state TriggerType-Choice-L2state, + ..., + triggerType-Choice-UEcontext TriggerType-Choice-UEcontext, + triggerType-Choice-L2MACschChg TriggerType-Choice-L2MACschChg +} + +``` + +``` + +TriggerType-Choice-RRCstate ::= SEQUENCE { + rrcState-List SEQUENCE (SIZE(1..maxnoofRRCstate)) OF TriggerType- +Choice-RRCstate-Item, + ... +} + +``` + +``` + +TriggerType-Choice-RRCstate-Item ::= SEQUENCE { + stateChangedTo RRC-State, + logicalOR LogicalOR OPTIONAL, + ... +} + +``` + +``` + +TriggerType-Choice-UEID ::= SEQUENCE { + ueIDchange-ID INTEGER (1..512, ...), + ... +} + +``` + +``` + +TriggerType-Choice-L2state ::= SEQUENCE { + associatedL2variables RANParameter-Testing, + ... +} + +``` + +``` + +TriggerType-Choice-UEcontext ::= SEQUENCE { + +``` + +``` + + associatedUECtxtVariables RANParameter-Testing, + ... + } + +TriggerType-Choice-L2MACschChg ::= SEQUENCE { + L2MACschChgType L2MACschChgType-Choice, + ... +} + +L2MACschChgType-Choice ::= CHOICE { + triggerType-Choice-MIMOandBFconfig TriggerType-Choice-MIMOandBFconfig, + ... +} + +TriggerType-Choice-MIMOandBFconfig ::= SEQUENCE { + mIMOTransModeState ENUMERATED {enabled, disabled, ...}, + ... +} + +-- ***** +-- Action Definition OCTET STRING contents +-- ***** + +E2SM-RC-ActionDefinition ::= SEQUENCE { + ric-Style-Type RIC-Style-Type, + ric-actionDefinition-formats CHOICE { + actionDefinition-Format1 E2SM-RC-ActionDefinition-Format1, + actionDefinition-Format2 E2SM-RC-ActionDefinition-Format2, + actionDefinition-Format3 E2SM-RC-ActionDefinition-Format3, + ..., + actionDefinition-Format4 E2SM-RC-ActionDefinition-Format4 + }, + ... +} + +E2SM-RC-ActionDefinition-Format1 ::= SEQUENCE { + ranP-ToBeReported-List SEQUENCE (SIZE(1..maxnoofParametersToReport)) OF E2SM- +RC-ActionDefinition-Format1-Item, + ... +} + +E2SM-RC-ActionDefinition-Format1-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +E2SM-RC-ActionDefinition-Format2 ::= SEQUENCE { + ric-PolicyConditions-List SEQUENCE (SIZE(1..maxnoofPolicyConditions)) OF E2SM-RC- +ActionDefinition-Format2-Item, + ... +} + +E2SM-RC-ActionDefinition-Format2-Item ::= SEQUENCE { + ric-PolicyAction RIC-PolicyAction, + ric-PolicyConditionDefinition RANParameter-Testing OPTIONAL, + ..., + ric-PolicyConditionID Ric-PolicyConditionID OPTIONAL +} + +E2SM-RC-ActionDefinition-Format3 ::= SEQUENCE { + ric-InsertIndication-ID RIC-InsertIndication-ID, + ranP-InsertIndication-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF +E2SM-RC-ActionDefinition-Format3-Item, + ueID UEID OPTIONAL, + ... +} + +E2SM-RC-ActionDefinition-Format3-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ..., + +``` + +``` + +ranParameter-Definition RANParameter-Definition OPTIONAL +} + +E2SM-RC-ActionDefinition-Format4 ::= SEQUENCE { + ric-InsertStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF E2SM-RC- +ActionDefinition-Format4-Style-Item, + ueID UEID OPTIONAL, + ... +} + +E2SM-RC-ActionDefinition-Format4-Style-Item ::= SEQUENCE { + requested-Insert-Style-Type RIC-Style-Type, + ric-InsertIndication-List SEQUENCE (SIZE(1..maxnoofInsertIndicationActions)) OF +E2SM-RC-ActionDefinition-Format4-Indication-Item, + ... +} + +E2SM-RC-ActionDefinition-Format4-Indication-Item ::= SEQUENCE { + ric-InsertIndication-ID RIC-InsertIndication-ID, + ranP-InsertIndication-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF +E2SM-RC-ActionDefinition-Format4-RANP-Item, + ... +} + +E2SM-RC-ActionDefinition-Format4-RANP-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +-- ***** +-- Indication Header OCTET STRING contents +-- ***** + +E2SM-RC-IndicationHeader ::= SEQUENCE { + ric-indicationHeader-formats CHOICE { + indicationHeader-Format1 E2SM-RC-IndicationHeader-Format1, + indicationHeader-Format2 E2SM-RC-IndicationHeader-Format2, + ..., + indicationHeader-Format3 E2SM-RC-IndicationHeader-Format3 + }, + ... +} + +E2SM-RC-IndicationHeader-Format1 ::= SEQUENCE { + ric-eventTriggerCondition-ID RIC-EventTriggerCondition-ID OPTIONAL, + ... +} + +E2SM-RC-IndicationHeader-Format2 ::= SEQUENCE { + ueID UEID, + ric-InsertStyle-Type RIC-Style-Type, + ric-InsertIndication-ID RIC-InsertIndication-ID, + ... +} + +E2SM-RC-IndicationHeader-Format3 ::= SEQUENCE { + ric-eventTriggerCondition-ID RIC-EventTriggerCondition-ID OPTIONAL, + ueID UEID OPTIONAL, + ... +} + +-- ***** +-- Indication Message OCTET STRING contents +-- ***** + +E2SM-RC-IndicationMessage ::= SEQUENCE { + ric-indicationMessage-formats CHOICE { + indicationMessage-Format1 E2SM-RC-IndicationMessage-Format1, + indicationMessage-Format2 E2SM-RC-IndicationMessage-Format2, + indicationMessage-Format3 E2SM-RC-IndicationMessage-Format3, + indicationMessage-Format4 NULL, + indicationMessage-Format5 E2SM-RC-IndicationMessage-Format5, + ..., + +``` + +indicationMessage-Format6 + +E2SM-RC-IndicationMessage-Format6 + +``` + + }, + ... +} + +``` + +``` + +E2SM-RC-IndicationMessage-Format1 ::= SEQUENCE { + ranP-Reported-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF E2SM- +RC-IndicationMessage-Format1-Item, + ... +} + +``` + +``` + +E2SM-RC-IndicationMessage-Format1-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + ... +} + +``` + +``` + +E2SM-RC-IndicationMessage-Format2 ::= SEQUENCE { + ueParameter-List SEQUENCE (SIZE(1..maxnoofUEID)) OF E2SM-RC- +IndicationMessage-Format2-Item, + ... +} + +``` + +``` + +E2SM-RC-IndicationMessage-Format2-Item ::= SEQUENCE { + ueID UEID, + ranP-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF E2SM- +RC-IndicationMessage-Format2-RANParameter-Item, + ... +} + +``` + +``` + +E2SM-RC-IndicationMessage-Format2-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + ... +} + +``` + +``` + +E2SM-RC-IndicationMessage-Format3 ::= SEQUENCE { + cellInfo-List SEQUENCE (SIZE(1..maxnoofCellID)) OF E2SM-RC- +IndicationMessage-Format3-Item, + ... +} + +``` + +``` + +E2SM-RC-IndicationMessage-Format3-Item ::= SEQUENCE { + cellGlobal-ID CGI, + cellContextInfo OCTET STRING OPTIONAL, + cellDeleted BOOLEAN OPTIONAL, + neighbourRelation-Table NeighbourRelation-Info OPTIONAL, + ..., + mib OCTET STRING OPTIONAL, + servingCellConfigCommon ServingCellConfigCommon OPTIONAL +} + +``` + +``` + +ServingCellConfigCommon ::= SEQUENCE { + ssbPositionsInBurst OCTET STRING, + ssbPeriodicity ENUMERATED {ms5, ms10, ms20, ms40, ms80, ms160, ...}, + ssbSubcarrierSpacing ENUMERATED {kHz15, kHz30, kHz60, kHz120, kHz240, kHz480- +v1700, kHz960-v1700, ...}, + ... +} + +``` + +``` + +E2SM-RC-IndicationMessage-Format5 ::= SEQUENCE{ + ranP-Requested-List SEQUENCE (SIZE(0..maxnoofAssociatedRANParameters)) OF E2SM- +RC-IndicationMessage-Format5-Item, + ... +} + +``` + +``` + +E2SM-RC-IndicationMessage-Format5-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + ... +} + +``` + +``` + +} + +E2SM-RC-IndicationMessage-Format6 ::= SEQUENCE { + ric-InsertStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF E2SM-RC- +IndicationMessage-Format6-Style-Item, + ... +} + +E2SM-RC-IndicationMessage-Format6-Style-Item ::= SEQUENCE { + indicated-Insert-Style-Type RIC-Style-Type, + ric-InsertIndication-List SEQUENCE (SIZE(1..maxnoofInsertIndicationActions)) OF +E2SM-RC-IndicationMessage-Format6-Indication-Item, + ... +} + +E2SM-RC-IndicationMessage-Format6-Indication-Item ::= SEQUENCE { + ric-InsertIndication-ID RIC-InsertIndication-ID, + ranP-InsertIndication-List SEQUENCE (SIZE(0..maxnoofAssociatedRANParameters)) OF +E2SM-RC-IndicationMessage-Format6-RANP-Item , + ... +} + +E2SM-RC-IndicationMessage-Format6-RANP-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + ... +} + +-- ***** +-- Call Process ID OCTET STRING contents +-- ***** + +E2SM-RC-CallProcessID ::= SEQUENCE { + ric-callProcessID-formats CHOICE { + callProcessID-Format1 E2SM-RC-CallProcessID-Format1, + ... + }, + ... +} + +E2SM-RC-CallProcessID-Format1 ::= SEQUENCE { + ric-callProcess-ID RAN-CallProcess-ID, + ... +} + +-- ***** +-- Control Header OCTET STRING contents +-- ***** + +E2SM-RC-ControlHeader ::= SEQUENCE { + ric-controlHeader-formats CHOICE { + controlHeader-Format1 E2SM-RC-ControlHeader-Format1, + ... + controlHeader-Format2 E2SM-RC-ControlHeader-Format2, + controlHeader-Format3 E2SM-RC-ControlHeader-Format3, + controlHeader-Format4 E2SM-RC-ControlHeader-Format4 + }, + ... +} + +E2SM-RC-ControlHeader-Format1 ::= SEQUENCE { + ueID UEID, + ric-Style-Type RIC-Style-Type, + ric-ControlAction-ID RIC-ControlAction-ID, + ric-ControlDecision ENUMERATED {accept, reject, ...} OPTIONAL, + ... +} + +E2SM-RC-ControlHeader-Format2 ::= SEQUENCE { + ueID UEID OPTIONAL, + ric-ControlDecision ENUMERATED {accept, reject, ...} OPTIONAL, + ... +} + +E2SM-RC-ControlHeader-Format3 ::= SEQUENCE { + +``` + +``` + + ue-Group-ID UE-Group-ID, + ue-Group-Definition UE-Group-Definition, + ric-Style-Type RIC-Style-Type, + ric-ControlAction-ID RIC-ControlAction-ID, + ... +} + +E2SM-RC-ControlHeader-Format4 ::= SEQUENCE { + partial-ueID PartialUEID, + ric-Style-Type RIC-Style-Type, + ric-ControlAction-ID RIC-ControlAction-ID, + ric-ControlDecision ENUMERATED {accept, reject, ...} OPTIONAL, + ... +} + +-- +-- Control Message OCTET STRING contents +-- + +E2SM-RC-ControlMessage ::= SEQUENCE { + ric-controlMessage-formats CHOICE { + controlMessage-Format1 E2SM-RC-ControlMessage-Format1, + ..., + controlMessage-Format2 E2SM-RC-ControlMessage-Format2, + controlMessage-Format3 E2SM-RC-ControlMessage-Format3, + controlMessage-Format4 E2SM-RC-ControlMessage-Format4, + controlMessage-Format5 E2SM-RC-ControlMessage-Format5 + }, + ... +} + +E2SM-RC-ControlMessage-Format1 ::= SEQUENCE { + ranP-List SEQUENCE (SIZE(0..maxnoofAssociatedRANParameters)) OF E2SM-RC-ControlMessage-Format1-Item, + ... +} + +E2SM-RC-ControlMessage-Format1-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + ... +} + +E2SM-RC-ControlMessage-Format2 ::= SEQUENCE { + ric-ControlStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF E2SM-RC-ControlMessage-Format2-Style-Item, + ... +} + +E2SM-RC-ControlMessage-Format2-Style-Item ::= SEQUENCE { + indicated-Control-Style-Type RIC-Style-Type, + ric-ControlAction-List SEQUENCE (SIZE(1..maxnoofMulCtrlActions)) OF E2SM-RC-ControlMessage-Format2-ControlAction-Item, + ... +} + +E2SM-RC-ControlMessage-Format2-ControlAction-Item ::= SEQUENCE { + ric-ControlAction-ID RIC-ControlAction-ID, + ranP-List E2SM-RC-ControlMessage-Format1, + ... +} + +E2SM-RC-ControlMessage-Format3 ::= SEQUENCE { + listofEntityFilters SEQUENCE (SIZE(0..maxnoofAssociatedEntityFilters)) OF E2SM-RC-EntityFilter OPTIONAL, + entityAgnosticControlRanP-List SEQUENCE (SIZE(0..maxnoofAssociatedRANParameters)) OF EntityAgnostic-ranP-ControlParameters OPTIONAL, + ... +} + +E2SM-RC-EntityFilter ::= SEQUENCE { + entityFilter-ID EntityFilter-ID, + entityFilter-Definition RANParameter-Testing, + entitySpecificControlRanP-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF EntitySpecific-ranP-ControlParameters, + +``` + +``` + + ... +} + +EntityAgnostic-ranP-ControlParameters ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + ... +} + +EntitySpecific-ranP-ControlParameters ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + ... +} + +E2SM-RC-ControlMessage-Format4 ::= SEQUENCE { + ranP-List SEQUENCE (SIZE(0..maxnoofAssociatedRANParameters)) OF E2SM- +RC-ControlMessage-Format4-Item, + ... +} + +E2SM-RC-ControlMessage-Format4-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-Definition RANParameter-Definition OPTIONAL, + ... +} + +E2SM-RC-ControlMessage-Format5 ::= NULL + +-- ***** +-- Control Outcome OCTET STRING contents +-- ***** + +E2SM-RC-ControlOutcome ::= SEQUENCE { + ric-controlOutcome-formats CHOICE { + controlOutcome-Format1 E2SM-RC-ControlOutcome-Format1, + ..., + controlOutcome-Format2 E2SM-RC-ControlOutcome-Format2, + controlOutcome-Format3 E2SM-RC-ControlOutcome-Format3 }, + ... +} + +E2SM-RC-ControlOutcome-Format1 ::= SEQUENCE { + ranP-List SEQUENCE (SIZE(0..maxnoofRANOutcomeParameters)) OF E2SM-RC- +ControlOutcome-Format1-Item, + ... +} + +E2SM-RC-ControlOutcome-Format1-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-value RANParameter-Value, + ... +} + +E2SM-RC-ControlOutcome-Format2 ::= SEQUENCE { + ric-ControlStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF E2SM-RC- +ControlOutcome-Format2-Style-Item, + ... +} + +E2SM-RC-ControlOutcome-Format2-Style-Item ::= SEQUENCE { + indicated-Control-Style-Type RIC-Style-Type, + ric-ControlOutcome-List SEQUENCE (SIZE(1..maxnoofMulCtrlActions)) OF E2SM-RC- +ControlOutcome-Format2-ControlOutcome-Item, + ... +} + +E2SM-RC-ControlOutcome-Format2-ControlOutcome-Item ::= SEQUENCE { + ric-ControlAction-ID RIC-ControlAction-ID, + ranP-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF +E2SM-RC-ControlOutcome-Format2-RANP-Item, + ... +} + +``` + +``` + +E2SM-RC-ControlOutcome-Format2-RANP-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-value RANParameter-Value, + ... +} + +E2SM-RC-ControlOutcome-Format3 ::= SEQUENCE { + ranP-List SEQUENCE (SIZE(0..maxnoofRANOutcomeParameters)) OF E2SM- +RC-ControlOutcome-Format3-Item, + ... +} + +E2SM-RC-ControlOutcome-Format3-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType, + ... +} + +-- ***** +-- Query Header OCTET STRING contents +-- ***** + +E2SM-RC-QueryHeader ::= SEQUENCE { + ric-queryHeader-formats CHOICE { + queryHeader-Format1 E2SM-RC-QueryHeader-Format1, + ... + }, + ... +} + +E2SM-RC-QueryHeader-Format1 ::= SEQUENCE { + ric-Style-Type RIC-Style-Type, + associatedE2NodeInfo RANParameter-Testing OPTIONAL, + associatedUEInfo Associated-UE-Info OPTIONAL, + ... +} + +-- ***** +-- Query Definition OCTET STRING contents +-- ***** + +E2SM-RC-QueryDefinition ::= SEQUENCE { + ric-queryDefinition-formats CHOICE { + queryRequest-Format1 E2SM-RC-QueryDefinition-Format1, + ... + }, + ... +} + +E2SM-RC-QueryDefinition-Format1 ::= SEQUENCE { + ranP-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF E2SM- +RC-QueryDefinition-Format1-Item, + ... +} + +E2SM-RC-QueryDefinition-Format1-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-Definition RANParameter-Definition OPTIONAL, + ... +} + +-- ***** +-- Query Outcome OCTET STRING contents +-- ***** + +E2SM-RC-QueryOutcome ::= SEQUENCE { + ric-queryOutcome-formats CHOICE { + queryOutcome-Format1 E2SM-RC-QueryOutcome-Format1, + queryOutcome-Format2 E2SM-RC-QueryOutcome-Format2, + ... + }, + ... +} + +E2SM-RC-QueryOutcome-Format1 ::= SEQUENCE { + +``` + +``` + +cellInfo-List SEQUENCE (SIZE(1..maxnoofCellID)) OF E2SM-RC- +QueryOutcome-Format1-ItemCell, + ... +} + +E2SM-RC-QueryOutcome-Format1-ItemCell ::= SEQUENCE { + cellGlobal-ID CGI, + ranP-List SEQUENCE (SIZE(0..maxnoofAssociatedRANParameters)) OF E2SM- +RC-QueryOutcome-Format1-ItemParameters, + neighbourRelation-Table NeighbourRelation-Info OPTIONAL, + ..., + servingCellConfigCommon ServingCellConfigCommon OPTIONAL +} + +E2SM-RC-QueryOutcome-Format1-ItemParameters ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType OPTIONAL, + ... +} + +E2SM-RC-QueryOutcome-Format2 ::= SEQUENCE { + ueInfo-List SEQUENCE (SIZE(0..maxnoofUEID)) OF E2SM-RC-QueryOutcome- +Format2-ItemUE, + ... +} + +E2SM-RC-QueryOutcome-Format2-ItemUE ::= SEQUENCE { + ueID UEID, + ranP-List SEQUENCE (SIZE(0..maxnoofAssociatedRANParameters)) OF E2SM- +RC-QueryOutcome-Format2-ItemParameters, + ueFilterID UE-Filter-ID OPTIONAL, ... +} + +E2SM-RC-QueryOutcome-Format2-ItemParameters ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-valueType RANParameter-ValueType OPTIONAL, + ... +} + + +-- RAN Function Definition IEs + + +E2SM-RC-RANFunctionDefinition ::= SEQUENCE{ + ranFunction-Name RANfunction-Name, + ranFunctionDefinition-EventTrigger RANFunctionDefinition-EventTrigger OPTIONAL, + ranFunctionDefinition-Report RANFunctionDefinition-Report OPTIONAL, + ranFunctionDefinition-Insert RANFunctionDefinition-Insert OPTIONAL, + ranFunctionDefinition-Control RANFunctionDefinition-Control OPTIONAL, + ranFunctionDefinition-Policy RANFunctionDefinition-Policy OPTIONAL, + ..., + ranFunctionDefinition-Query RANFunctionDefinition-Query OPTIONAL +} + + +-- Event Trigger + + +RANFunctionDefinition-EventTrigger ::= SEQUENCE { + ric-EventTriggerStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF +RANFunctionDefinition-EventTrigger-Style-Item, + ran-L2Parameters-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF +L2Parameters-RANParameter-Item OPTIONAL, + ran-CallProcessTypes-List SEQUENCE (SIZE(1..maxnoofCallProcessTypes)) OF +RANFunctionDefinition-EventTrigger-CallProcess-Item OPTIONAL, + ran-UEIdentificationParameters-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF +UEIdentification-RANParameter-Item OPTIONAL, + ran-CellIdentificationParameters-List SEQUENCE (SIZE(1..maxnoofAssociatedRANParameters)) OF +CellIdentification-RANParameter-Item OPTIONAL, + ... +} + +RANFunctionDefinition-EventTrigger-Style-Item ::= SEQUENCE { + ric-EventTriggerStyle-Type RIC-Style-Type, + ric-EventTriggerStyle-Name RIC-Style-Name, + ric-EventTriggerFormat-Type RIC-Format-Type, + ... +} + +``` + +``` + +L2Parameters-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +UEIdentification-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +CellIdentification-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +RANFunctionDefinition-EventTrigger-CallProcess-Item ::= SEQUENCE { + callProcessType-ID RIC-CallProcessType-ID, + callProcessType-Name RIC-CallProcessType-Name, + callProcessBreakpoints-List SEQUENCE (SIZE (1..maxnoofCallProcessBreakpoints)) OF +RANFunctionDefinition-EventTrigger-Breakpoint-Item, + ... +} + +RANFunctionDefinition-EventTrigger-Breakpoint-Item ::= SEQUENCE { + callProcessBreakpoint-ID RIC-CallProcessBreakpoint-ID, + callProcessBreakpoint-Name RIC-CallProcessBreakpoint-Name, + ran-CallProcessBreakpointParameters-List SEQUENCE (SIZE (1..maxnoofAssociatedRANParameters)) +OF CallProcessBreakpoint-RANParameter-Item OPTIONAL, + ... +} + +CallProcessBreakpoint-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +----- +-- Report +----- + +RANFunctionDefinition-Report ::= SEQUENCE { + ric-ReportStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF +RANFunctionDefinition-Report-Item, + ... +} + +RANFunctionDefinition-Report-Item ::= SEQUENCE { + ric-ReportStyle-Type RIC-Style-Type, + ric-ReportStyle-Name RIC-Style-Name, + ric-SupportedEventTriggerStyle-Type RIC-Style-Type, + ric-ReportActionFormat-Type RIC-Format-Type, + ric-IndicationHeaderFormat-Type RIC-Format-Type, + ric-IndicationMessageFormat-Type RIC-Format-Type, + ran-ReportParameters-List SEQUENCE (SIZE (1..maxnoofAssociatedRANParameters)) OF +Report-RANParameter-Item OPTIONAL, + ... +} + +Report-RANParameter-Item ::= SEQUENCE { + +``` + +``` + +ranParameter-ID RANParameter-ID, +ranParameter-name RANParameter-Name, +..., +ranParameter-Definition RANParameter-Definition OPTIONAL +} + +----- +-- Insert +----- + +RANFunctionDefinition-Insert ::= SEQUENCE { + ric-InsertStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF +RANFunctionDefinition-Insert-Item, + ... +} + +RANFunctionDefinition-Insert-Item ::= SEQUENCE { + ric-InsertStyle-Type RIC-Style-Type, + ric-InsertStyle-Name RIC-Style-Name, + ric-SupportedEventTriggerStyle-Type RIC-Style-Type, + ric-ActionDefinitionFormat-Type RIC-Format-Type, + ric-InsertIndication-List SEQUENCE (SIZE(1..maxnoofInsertIndication)) OF +RANFunctionDefinition-Insert-Indication-Item OPTIONAL, + ric-IndicationHeaderFormat-Type RIC-Format-Type, + ric-IndicationMessageFormat-Type RIC-Format-Type, + ric-CallProcessIDFormat-Type RIC-Format-Type, + ... +} + +RANFunctionDefinition-Insert-Indication-Item ::= SEQUENCE { + ric-InsertIndication-ID RIC-InsertIndication-ID, + ric-InsertIndication-Name RIC-InsertIndication-Name, + ran-InsertIndicationParameters-List SEQUENCE (SIZE (1..maxnoofAssociatedRANParameters)) OF +InsertIndication-RANParameter-Item OPTIONAL, + ... +} + +InsertIndication-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +----- +-- Control +----- + +RANFunctionDefinition-Control ::= SEQUENCE { + ric-ControlStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF +RANFunctionDefinition-Control-Item, + ... +} + +RANFunctionDefinition-Control-Item ::= SEQUENCE { + ric-ControlStyle-Type RIC-Style-Type, + ric-ControlStyle-Name RIC-Style-Name, + ric-ControlAction-List SEQUENCE (SIZE(1..maxnoofControlAction)) OF +RANFunctionDefinition-Control-Action-Item OPTIONAL, + ric-ControlHeaderFormat-Type RIC-Format-Type, + ric-ControlMessageFormat-Type RIC-Format-Type, + ric-CallProcessIDFormat-Type RIC-Format-Type OPTIONAL, + ric-ControlOutcomeFormat-Type RIC-Format-Type, + ran-ControlOutcomeParameters-List SEQUENCE (SIZE(1..maxnoofRANOutcomeParameters)) OF +ControlOutcome-RANParameter-Item OPTIONAL, + ..., + listOfAdditionalSupportedFormats ListOfAdditionalSupportedFormats OPTIONAL} + +ControlOutcome-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +``` + +} + +``` + +RANFunctionDefinition-Control-Action-Item ::= SEQUENCE { + ric-ControlAction-ID RIC-ControlAction-ID, + ric-ControlAction-Name RIC-ControlAction-Name, + ran-ControlActionParameters-List SEQUENCE (SIZE (1..maxnoofAssociatedRANParameters)) OF +ControlAction-RANParameter-Item OPTIONAL, + ..., + ueGroup-ControlAction-Supported ENUMERATED {true, false, ...} OPTIONAL +} + +``` + +``` + +ControlAction-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +``` + +``` + +ListOfAdditionalSupportedFormats ::= SEQUENCE (SIZE(0..maxnoofFormatTypes)) OF +AdditionalSupportedFormat + +``` + +``` + +AdditionalSupportedFormat ::= SEQUENCE { + ric-ControlHeaderFormat-Type RIC-Format-Type, + ric-ControlMessageFormat-Type RIC-Format-Type, + ..., + ric-ControlOutcomeFormat-Type RIC-Format-Type OPTIONAL, + ric-ControlAction-ID RIC-ControlAction-ID OPTIONAL +} + +``` + +``` + +----- +-- Policy +----- + +``` + +``` + +RANFunctionDefinition-Policy ::= SEQUENCE { + ric-PolicyStyle-List SEQUENCE (SIZE(1..maxnoofRICStyles)) OF +RANFunctionDefinition-Policy-Item, + ... +} + +``` + +``` + +RANFunctionDefinition-Policy-Item ::= SEQUENCE { + ric-PolicyStyle-Type RIC-Style-Type, + ric-PolicyStyle-Name RIC-Style-Name, + ric-SupportedEventTriggerStyle-Type RIC-Style-Type, + ric-PolicyAction-List SEQUENCE (SIZE(1..maxnoofPolicyAction)) OF +RANFunctionDefinition-Policy-Action-Item OPTIONAL, + ... +} + +``` + +``` + +RANFunctionDefinition-Policy-Action-Item ::= SEQUENCE { + ric-PolicyAction-ID RIC-ControlAction-ID, + ric-PolicyAction-Name RIC-ControlAction-Name, + ric-ActionDefinitionFormat-Type RIC-Format-Type, + ran-PolicyActionParameters-List SEQUENCE (SIZE (1..maxnoofAssociatedRANParameters)) OF +PolicyAction-RANParameter-Item OPTIONAL, + ran-PolicyConditionParameters-List SEQUENCE (SIZE (1..maxnoofAssociatedRANParameters)) OF +PolicyCondition-RANParameter-Item OPTIONAL, + ... +} + +``` + +``` + +PolicyAction-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +``` + +``` + +PolicyCondition-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ..., + ranParameter-Definition RANParameter-Definition OPTIONAL +} + +``` + +``` + + +-- Query + + +``` + +``` + +RANFunctionDefinition-Query ::= SEQUENCE { + ric-QueryStyle-List SEQUENCE (SIZE (1..maxnoofRICStyles)) OF RANFunctionDefinition-Query-Item, + ... +} + +``` + +``` + +RANFunctionDefinition-Query-Item ::= SEQUENCE { + ric-QueryStyle-Type RIC-Style-Type, + ric-QueryStyle-Name RIC-Style-Name, + ric-QueryHeaderFormat-Type RIC-Format-Type, + ric-QueryDefinitionFormat-Type RIC-Format-Type, + ric-QueryOutcomeFormat-Type RIC-Format-Type, + ran-QueryParameters-List SEQUENCE (SIZE (1..maxnoofAssociatedRANParameters)) OF Query-RANParameter-Item OPTIONAL, + ... +} + +``` + +``` + +Query-RANParameter-Item ::= SEQUENCE { + ranParameter-ID RANParameter-ID, + ranParameter-name RANParameter-Name, + ranParameter-Definition RANParameter-Definition OPTIONAL, + ... +} + +``` + +``` + +E2SM-RC-ServiceLayerCause ::= CHOICE { + ricRequest CauseRICrequest, + ricService CauseRICservice, + protocol CauseProtocol, + ... +} + +``` + +``` + +CauseRICservice ::= ENUMERATED{ + RIC-Event-Trigger-Style-Type-not-supported, + RIC-Event-Trigger-Format-Type-not-supported, + RAN-Parameter-ID-not-supported, + Call-Process-Type-ID-not-supported, + Call-Process-Breakpoint-ID-not-supported, + RIC-Report-Style-Type-not-supported, + Supported-RIC-Event-Trigger-Style-Type-not-supported, + RIC-Action-Format-Type-not-supported, + RIC-Indication-Header-Format-Type-not-supported, + RIC-Indication-Message-Format-Type-not-supported, + RIC-Insert-Style-Type-not-supported, + Insert-Indication-ID-not-supported, + RIC-Call-Process-ID-Format-Type-not-supported, + RIC-Control-Style-Type-not-supported, + Control-Action-ID-not-supported, + RIC-Control-Header-Format-Type-not-supported, + RIC-Control-Message-Format-Type-not-supported, + RIC-Control-Outcome-Format-Type-not-supported, + RIC-Policy-Style-Type-not-supported, + Policy-Action-ID-not-supported, + RIC-Query-Style-Type-not-supported, + RIC-Query-Header-Format-Type-not-supported, + RIC-Query-Definition-Format-Type-not-supported, + RIC-Query-Outcome-Format-Type-not-supported, + ... +} + +``` + +``` + +CauseProtocol ::= ENUMERATED { + transfer-syntax-error, + abstract-syntax-error-reject, + abstract-syntax-error-ignore-and-notify, + message-not-compatible-with-receiver-state, + semantic-error, + abstract-syntax-error-falsely-constructed-message, + unspecified, + ... +} + +``` + +END + +-- ASN1STOP + +## 9.5 Message transfer syntax + +E2SM-RC shall use the ASN.1 Basic Packed Encoding Rules (BASIC-PER) Aligned Variant as transfer syntax, as specified in ITU-T Rec. X.691 [9]. + +--- + +## 10 Handling of Unknown, Unforeseen and Erroneous Protocol Data + +Clause 10 of TS 36.413 [13] is applicable for the purposes of the present document. + +## Annex A (Informative): + +### Examples on IE Contents + +#### A.1 Introduction + +This annex presents example applications of selected use cases showing alternative solutions using different combinations of RIC Services Report, Insert, Control and/or Policy. + +#### A.2 Connected mode mobility based on UE measurement report + +##### A.2.1 Assumptions + +This example is based on the following assumptions: + +- 1 E2 Node, of type O-CU-CP, O-CU or gNB for aggregated deployments, has E2 interface to Near-RT RIC and supports one or more RIC services using E2SM-RC. +- 2 UE is in RRC CONNECTED state using NR access and has successfully attached to a 5G Core Network (5GC) +- 3 UE has been previously configured to send RRC Measurement Reports. +- 4 UE sends a RRC Measurement Report containing one or more neighbour cell measurements applicable for an inter-cell connected mode mobility event (i.e. a Handover) +- 5 E2 Node for aggregated deployments, uses one or more RIC Services to complete the handover decision and either execute handover (i.e. using procedure described in 3GPP 38.300 clause 9.2.3) or ignores measurement report. + +Step 5 may be realized using one or more of the following solutions: + +- i) According to a previously established RIC Subscription procedure, the arrival of the RRC Measurement Report triggers an Event Trigger which results in the E2 Node suspending the ongoing call process and sending a RIC Service INSERT message to the Near-RT RIC. The Near-RT RIC takes the Handover Decision and sends a RIC Service CONTROL message carrying the response which is used by the E2 node to resume the call process. +- ii) According to a previously established RIC Subscription procedure the arrival of the RRC Measurement Report triggers an Event Trigger which results in the E2 Node executing a RIC Service POLICY which is used to modify the default Handover Decision and so modifies the remaining steps in the ongoing call process. + +##### A.2.2 Solution using RIC Services Insert and Control + +###### A.2.2.0 Introduction + +This section provides a solution for the Connected Mode Mobility event call flow using the RIC Service Insert (Style 3) and Control (Style 3) required for the handling of incoming RRC Measurement reports from a UE connected to a 5GC network using Standalone (SA) access. Corresponding example message content are provided for the *RIC Event Trigger Definition* IE and *RIC Action Definition* IE, used to set up the RIC Subscription for the Insert service, the *RIC Indication Header* IE and *RIC Indication Message* IE, used to send the Insert message to the Near-RT RIC and finally the *RIC Control Header* IE, *RIC Control Message* IE and *RIC Control Outcome* IE contents, used by the resulting RIC Control procedure to respond to the Insert message. + +###### A.2.2.1 Assumptions + +This example is based on the following design assumptions: + +- 1 Event trigger defined using Style 2 (Call Process Breakpoint), Type 3 (Mobility Management) and Call Breakpoint ID 1 (Handover Preparation) with the assumption that this breakpoint corresponds to the point of the UE call process code in a gNB where a handover decision is to be taken based on a received RRC Measurement report. + - a. *Event Trigger Definition Format 2* IE RAN parameters for *Associated UE Info* IE are used to offer filtering of UE between UE subject to Insert service and UE to be handled using E2 Node internal mechanisms. In this example RAN parameters for discrimination based on Slice and Group (aka SPID) along with optional use of Explicit UE List membership are described (see A.2.2.2). +- 2 Insert service, defined according to Insert Style 3 (Connected Mobile Mobility Control Request), Indication ID 1 (Handover control request), is defined using *RIC Action Definition Format 3* IE. In this example a single target primary cell along with lists of PDU, DRB and secondary cells to be handed over are described (see A.2.2.3) +- 3 Insert message defined according to Insert Style 3 (Connected Mobile Mobility Control Request), Indication ID 1 (Handover control request) with *RIC Indication Header Format 2* IE, *RIC Indication Message Format 5* IE and *RIC Call Process ID Format 1* IE. In this example the insert message, used to carry preliminary handover decision made by E2 Node (target primary cell selected and proposed lists of retained DRBs and secondary cells), is described (see A.2.2.4) +- 4 Control message defined according to Control Style 3 (Connected Mobile Mobility Control), Control Action ID 1 (Handover control) with *RIC Control Header Format 1* IE, *RIC Control Message Format 1* IE, *RIC Call Process ID Format 1* IE and *RIC Control Outcome Format 1* IE, may be sent based on the outcome of the decision in the Near-RT RIC. Message is used to carry confirmed handover decision made by E2 Node (confirmed target primary cell and confirmed lists of retained DRBs and secondary cells). + +The gNB may either: + +- a. Use the *RIC Call Process ID* IE to identify the target UE and decide to accept the RIC Control request. The E2 Node may then proceed with handover execution using information obtained from the measurement report, stored UE context information and contents of the RIC Control Request message (*RIC Control Header* IE and *RIC Control Message* IE) result of subsequent network transactions + - b. Wait for the Time To Wait timer to expire and continue with any other required call processing, ignoring the measurement report +- 5 *RIC Control Outcome* IE carried in RIC Control Acknowledge message, defined using Control Style 3 (Connected Mobile Mobility Control), Control Action ID 1 (Handover control), may be sent based on the outcome of the decision in the E2 Node + +``` +@startuml +Skin rose +skinparam ParticipantPadding 50 +skinparam BoxPadding 10 +skinparam lifelineStrategy solid + +Participant "Near-RT RIC" as RIC +Participant "gNB" as gNB + +Participant "UE" as UE + +== Establish RIC subscriptions == +RIC-->gNB: <color green>RIC SUBSCRIPTION (Insert: Handover measurement report) + +RIC-->gNB: <color green>RIC CONTROL (UE assignment to Explicit UE List) + +loop While Subscription remains active + == Handover decision == + UE->>gNB: RRC Measurement report + gNB->gNB: Handover decision + gNB->gNB: <color green>Call Process Breakpoint + gNB->gNB: <color green>Event Trigger (test conditions) + alt #lime Event Trigger Condition applies + note over gNB #pink: Associated procedure instance **suspended** note over gNB + #aqua: Start associated Time to Wait Timer + gNB->RIC: RIC Indication (Insert) based on Action Definition \ncontaining preliminary +handover decision +``` + +``` + + alt #lime Near-RT RIC __responds in time__ + RIC->RIC: Confirm preliminary handover decision and downselect \nretained DRBs and +S-cells if required + RIC->gNB: RIC Control request (handover information) + note over gNB #pink: Associated procedure instance **recovered** + gNB->gNB: Modify handover decision \naccording to Control request + gNB-->RIC: RIC Control Acknowledge + else Time to Wait timer Expires and Subsequent Action = __Continue__ + note over gNB #aqua: Associated Time to Wait Timer expires + note over gNB #pink: Associated procedure instance **recovered** + end +end +alt Handover decision = TRUE + gNB<->UE: Execute handover +else Handover decision = FALSE + gNB->gNB: Ignore measurement report +end +end +@enduml + +``` + +![Sequence diagram showing the call flow for Handover preparation and execution with extensions added to implement RIC Insert and RIC Control service in GREEN. The diagram involves three lifelines: Near-RT RIC, gNB, and UE. The process starts with 'Establish RIC subscriptions' where gNB sends 'RIC SUBSCRIPTION (Insert: Handover measurement report)' and 'RIC CONTROL (UE assignment to Explicit UE List)' to Near-RT RIC. A loop '[While Subscription remains active]' contains a 'Handover decision' block. Inside this block, gNB sends 'RRC Measurement report' to UE, which then sends 'Handover decision', 'Call Process Breakpoint', and 'Event Trigger (test conditions)' back to gNB. An 'alt' block '[Event Trigger Condition applies]' shows the 'Associated procedure instance suspended' and 'Start associated Time to Wait Timer'. Near-RT RIC sends 'RIC Indication (Insert) based on Action Definition containing preliminary handover decision' to gNB. Another 'alt' block '[Near-RT RIC responds in time]' shows gNB sending 'RIC Control request (handover information)' to Near-RT RIC, which responds with 'RIC Control Acknowledge'. The 'Associated procedure instance recovered' and 'Modify handover decision according to Control request' occurs. A dashed line indicates '[Time to Wait timer Expires and Subsequent Action = Continue]', followed by 'Associated Time to Wait Timer expires' and 'Associated procedure instance recovered'. A final 'alt' block shows '[Handover decision = TRUE]' leading to 'Execute handover' and '[Handover decision = FALSE]' leading to 'Ignore measurement report'.](a55ba4c7522c2f205dc75aceded51060_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant gNB + participant UE + + Note over gNB: Establish RIC subscriptions + gNB->>Near-RT RIC: RIC SUBSCRIPTION (Insert: Handover measurement report) + gNB->>Near-RT RIC: RIC CONTROL (UE assignment to Explicit UE List) + + loop [While Subscription remains active] + Note over gNB: Handover decision + gNB->>UE: RRC Measurement report + UE->>gNB: Handover decision + UE->>gNB: Call Process Breakpoint + UE->>gNB: Event Trigger (test conditions) + + alt [Event Trigger Condition applies] + Note over gNB: Associated procedure instance suspended + Note over gNB: Start associated Time to Wait Timer + + Near-RT RIC->>gNB: RIC Indication (Insert) based on Action Definition containing preliminary handover decision + + alt [Near-RT RIC responds in time] + gNB->>Near-RT RIC: RIC Control request (handover information) + Near-RT RIC->>gNB: RIC Control Acknowledge + Note over gNB: Associated procedure instance recovered + Note over gNB: Modify handover decision according to Control request + else [Time to Wait timer Expires and Subsequent Action = Continue] + Note over gNB: Associated Time to Wait Timer expires + Note over gNB: Associated procedure instance recovered + end + end + + alt + [Handover decision = TRUE] + gNB->>UE: Execute handover + [Handover decision = FALSE] + gNB->>UE: Ignore measurement report + end + end + +``` + +Sequence diagram showing the call flow for Handover preparation and execution with extensions added to implement RIC Insert and RIC Control service in GREEN. The diagram involves three lifelines: Near-RT RIC, gNB, and UE. The process starts with 'Establish RIC subscriptions' where gNB sends 'RIC SUBSCRIPTION (Insert: Handover measurement report)' and 'RIC CONTROL (UE assignment to Explicit UE List)' to Near-RT RIC. A loop '[While Subscription remains active]' contains a 'Handover decision' block. Inside this block, gNB sends 'RRC Measurement report' to UE, which then sends 'Handover decision', 'Call Process Breakpoint', and 'Event Trigger (test conditions)' back to gNB. An 'alt' block '[Event Trigger Condition applies]' shows the 'Associated procedure instance suspended' and 'Start associated Time to Wait Timer'. Near-RT RIC sends 'RIC Indication (Insert) based on Action Definition containing preliminary handover decision' to gNB. Another 'alt' block '[Near-RT RIC responds in time]' shows gNB sending 'RIC Control request (handover information)' to Near-RT RIC, which responds with 'RIC Control Acknowledge'. The 'Associated procedure instance recovered' and 'Modify handover decision according to Control request' occurs. A dashed line indicates '[Time to Wait timer Expires and Subsequent Action = Continue]', followed by 'Associated Time to Wait Timer expires' and 'Associated procedure instance recovered'. A final 'alt' block shows '[Handover decision = TRUE]' leading to 'Execute handover' and '[Handover decision = FALSE]' leading to 'Ignore measurement report'. + +Figure A.2.2.1-1: Example call flow for Handover preparation and execution with extensions added to implement RIC Insert and RIC Control service in GREEN + +### A.2.2.2 RIC Event Trigger Definition IE contents + +*RIC Event Trigger Definition Format 2* IE contains RAN Parameter lists for *Associated E2 Node Info* IE and *Associated UE info* IE. + +In this example: + +- 1) *Associated E2 Node Info* IE, using RAN Parameters from clause 8.1.2.3.1, is not used. +- 2) *Associated UE Info* IE, using RAN Parameters from clause 8.1.3, is used where the set of target UEs for the event is defined by a given slice (SST=sst1, SD=sd1) and group (IRFSP=irfsp1) along with membership to an optional Explicit UE list. Additional sets of target UEs may be supported using the same RAN Parameter list with different target values for SST, SD and IRFSP and optionally Explicit UE List. In addition, individual target UE may be identified. These selection criteria would be combined within the *Event Trigger UE Information* IE using the optional "Logical OR" flag (see clause 9.3.26). + +RAN Parameter Testing for Call Process Breakpoint (defined in 8.1.2.3.1), used to populate the *Associated E2 Node Info* IE, are as follows: + +| RAN Parameter ID | Value type | Key flag | Value | Test condition | Semantics Description | +|------------------|------------|----------|-------|----------------|-----------------------| +| (N/A) | | | | | | + +RAN Parameter Testing for UE Group (defined in 8.1.3), used to populate the *Associated UE Info* IE, are as follows: + +| RAN Parameter ID | Value type | Key flag | Value | Test condition | Semantics Description | +|------------------|------------|----------|---------|----------------|-----------------------| +| 35010 | STRUCTURE | | | | S-NSSAI | +| 35011 | ELEMENT | FALSE | sst1 | equal | >SST | +| 35012 | ELEMENT | FALSE | sd1 | equal | >SD | +| 35020 | STRUCTURE | | | | Group ID | +| 35021 | ELEMENT | FALSE | irfsp1 | equal | >IRFSP | +| 35030 | ELEMENT | FALSE | HOList1 | Equal | Explicit UE List ID | + +### A.2.2.3 RIC Action Definition IE contents + +*RIC Action Definition Format 3* IE used to define Insert service contains a single RAN Parameter list for the selection of information such as Target Primary Cell, List of PDU sessions to be handed over and List of DRBs to be handed over. This information is to be reported to Near-RT RIC within the INSERT message. + +RAN parameters for Insert service (according to clause 8.3.4.1, these are defined in clause 8.4.4.1), used to populate the *List of RAN parameters for Insert Indication IE*, are as follows: + +| RAN Parameter ID | Value type | Key flag | Value | Test condition | Semantics Description | +|------------------|------------|----------|---------|----------------|----------------------------------------| +| 1 | STRUCTURE | | | | Target Primary Cell ID | +| 2 | STRUCTURE | | | | >CHOICE Target Cell | +| 3 | STRUCTURE | | | | >>NR Cell | +| 4 | ELEMENT | FALSE | Nr-cgi1 | | >>>NR CGI | +| 7 | STRUCTURE | | | | List of PDU sessions for handover | +| 8 | STRUCTURE | | | | >>PDU session Item for handover | +| 9 | ELEMENT | TRUE | Pdu#M | | >>PDU Session ID | +| 10 | STRUCTURE | | | | >>List of QoS flows in the PDU session | +| 11 | STRUCTURE | | | | >>>QoS flow Item | +| 12 | ELEMENT | TRUE | Qfi#N | | >>>>QoS Flow Identifier | +| 13 | STRUCTURE | | | | List of DRBs for handover | +| 14 | STRUCTURE | | | | >DRB item for handover | +| 15 | ELEMENT | TRUE | Drb#P | | > DRB ID | +| 16 | LIST | | | | >>List of QoS flows in the DRB | +| 17 | STRUCTURE | | | | >>>QoS flow item | +| 18 | ELEMENT | TRUE | Qfi#Q | | >>>>QoS flow Identifier | +| 19 | LIST | | | | List of Secondary cells to be setup | +| 20 | STRUCTURE | | | | > Secondary cell item to be setup | +| 21 | ELEMENT | | Scell#S | | >>Secondary cell ID | + +#### A.2.2.4 RIC Indication Message + +RAN Parameters for Connected Mode Mobility Control (according to clause 8.3.4.1 these are defined in clause 8.4.4.1), used to populate the *RIC Indication Message Format 5 IE*, are the same as those defined in A.2.2.3 above. + +NOTE: Only one target primary cell is supported in the current version of this specification. + +#### A.2.2.5 RIC Control Message + +RAN Parameters for Connected Mode Mobility Control (according to clause 8.3.4.1 these are defined in 8.4.4.1), used to populate the *RIC Control Message Format 1 IE*, are the same as those defined in A.2.2.3 above. + +### A.2.3 Solution using RIC Service Policy ("Offset" based approach) + +#### A.2.3.0 Introduction + +This section provides a solution for the Connected Mode Mobility event call flow using the RIC Service Policy using the "Offset" approach. Corresponding example message content are provided for the *RIC Event Trigger Definition IE* + +and *RIC Action Definition* IE contents for the Connected Mode Mobility service (Policy Style 3) sent from the RIC to the E2 node to establish a policy used to provide guidance for the handling of incoming RRC Measurement reports from a UE connected to a 5GC network using Standalone (SA) access. + +### A.2.3.1 Assumptions + +This example is based on the following design assumptions: + +- 1 Event trigger defined using Style 2 (Call Process Breakpoint), Type 3 (Mobility Management) and Call Breakpoint ID 1 (handover Preparation) with the assumption that this breakpoint corresponds to the point of the UE call process code in a gNB where a handover decision is to be taken based on a received RRC Measurement report. + - a. *E2SM-RC Event Trigger Definition Format 2* IE RAN parameters for *Associated E2 Node Info* IE are not used + - b. *E2SM-RC Event Trigger Definition Format 2* IE RAN parameters for *Associated UE Info* IE are used to offer filtering of UE between those subject to Policy handling and those to be handled using default parameters. In this example RAN parameters for discrimination based on Slice and Group (aka SPID) are described. +- 2 Policy defined using Style 3 (Connected Mobile Mobility Policy), Policy Action ID 1 (Policy for Handover control) and installed using RIC Subscription procedure containing *E2SM-RC Action Definition Format 2* IE: + - a. *Policy Condition Definition* IE RAN parameters used to map UE to an appropriate Policy Action. In this example RAN parameters based on Serving Cell and Explicit UE List membership are described. + - b. *Policy Action* IE parameters used to define a set of offsets (+positive, zero or -negative values) to be applied to default measurement thresholds to calculate policy modified threshold used during Handover decision prior to Handover execution. +- 3 Depending upon the outcome of the decision the gNB either: + - a. Proceeds with handover execution using information obtained from the measurement report, stored UE context information and result of subsequent network transactions + - b. Ignores measurement report and continues any other required call processing + +``` +@startuml +Skin rose + +skinparam ParticipantPadding 50 +skinparam BoxPadding 10 +skinparam lifelineStrategy solid + +Participant "Near-RT RIC" as RIC +Participant "gNB" as gNB + +Participant "UE" as UE + +== Establish RIC subscriptions == +RIC->>gNB: <color green>RIC SUBSCRIPTION (Policy: Handover decision) + +RIC<-->gNB: <color green>RIC CONTROL (UE assignment to Explicit UE List) + +loop While Subscription remains active + == Handover decision == + UE->>gNB: 1) RRC Measurement report + + gNB->>gNB : <color green>Call Process Breakpoint + gNB->>gNB: <color green>Event Trigger (test conditions) + alt #lime Event Trigger Condition applies + alt #lime Policy condition applies (first match in list) + gNB->>gNB: Extract offset value(s) from Policy Action + else no Policy condition applies + gNB->>gNB: Set offset value(s) to zero + end + else Event Trigger condition does not apply +``` + +``` + +gNB->gNB : Set offset value(s) to zero +end + +gNB->gNB: Handover decision using default threshold <color green>modified \n<color +green>according to offset value(s) in policy action </color> + +alt Handover decision = TRUE + gNB->UE: Execute handover +else Handover decision = FALSE + gNB->gNB: Ignore measurement report +end +end +@enduml + +``` + +![Sequence diagram showing the call flow for Handover preparation with extensions added to implement E2 Policy service in GREEN. The diagram involves three lifelines: Near-RT RIC, gNB, and UE. The process starts with 'Establish RIC subscriptions' where Near-RT RIC sends 'RIC SUBSCRIPTION (Policy: Handover decision)' and receives 'RIC CONTROL (UE assignment to Explicit UE List)' from gNB. A loop 'While Subscription remains active' contains a 'Handover decision' block. Inside this block, gNB receives '1) RRC Measurement report' from UE, then performs 'Call Process Breakpoint' and 'Event Trigger (test conditions)'. An 'alt' block '[Event Trigger Condition applies]' contains two sub-alternatives: '[Policy condition applies (first match in list)]' where gNB sends 'Extract offset value(s) from Policy Action' to Near-RT RIC, and '[no Policy condition applies]' where gNB sends 'Set offset value(s) to zero' to Near-RT RIC. Another alternative '[Event Trigger condition does not apply]' also sends 'Set offset value(s) to zero' to Near-RT RIC. Following this, gNB sends 'Handover decision using default threshold modified according to offset value(s) in policy action' to Near-RT RIC. A final 'alt' block shows '[Handover decision = TRUE]' where gNB sends 'Execute handover' to UE, and '[Handover decision = FALSE]' where gNB sends 'Ignore measurement report' to UE.](e5e9cc82d567781d4fd1b713b983e827_img.jpg) + +``` + +sequenceDiagram + participant Near-RT RIC + participant gNB + participant UE + + Note over Near-RT RIC, gNB: Establish RIC subscriptions + Near-RT RIC->>gNB: RIC SUBSCRIPTION (Policy: Handover decision) + gNB-->>Near-RT RIC: RIC CONTROL (UE assignment to Explicit UE List) + + loop While Subscription remains active + Note over gNB: Handover decision + UE->>gNB: 1) RRC Measurement report + gNB->>gNB: Call Process Breakpoint + gNB->>gNB: Event Trigger (test conditions) + + alt [Event Trigger Condition applies] + alt [Policy condition applies (first match in list)] + gNB->>Near-RT RIC: Extract offset value(s) from Policy Action + else [no Policy condition applies] + gNB->>Near-RT RIC: Set offset value(s) to zero + end + else [Event Trigger condition does not apply] + gNB->>Near-RT RIC: Set offset value(s) to zero + end + + gNB->>Near-RT RIC: Handover decision using default threshold modified +according to offset value(s) in policy action + + alt [Handover decision = TRUE] + gNB->>UE: Execute handover + else [Handover decision = FALSE] + gNB->>UE: Ignore measurement report + end + end + +``` + +Sequence diagram showing the call flow for Handover preparation with extensions added to implement E2 Policy service in GREEN. The diagram involves three lifelines: Near-RT RIC, gNB, and UE. The process starts with 'Establish RIC subscriptions' where Near-RT RIC sends 'RIC SUBSCRIPTION (Policy: Handover decision)' and receives 'RIC CONTROL (UE assignment to Explicit UE List)' from gNB. A loop 'While Subscription remains active' contains a 'Handover decision' block. Inside this block, gNB receives '1) RRC Measurement report' from UE, then performs 'Call Process Breakpoint' and 'Event Trigger (test conditions)'. An 'alt' block '[Event Trigger Condition applies]' contains two sub-alternatives: '[Policy condition applies (first match in list)]' where gNB sends 'Extract offset value(s) from Policy Action' to Near-RT RIC, and '[no Policy condition applies]' where gNB sends 'Set offset value(s) to zero' to Near-RT RIC. Another alternative '[Event Trigger condition does not apply]' also sends 'Set offset value(s) to zero' to Near-RT RIC. Following this, gNB sends 'Handover decision using default threshold modified according to offset value(s) in policy action' to Near-RT RIC. A final 'alt' block shows '[Handover decision = TRUE]' where gNB sends 'Execute handover' to UE, and '[Handover decision = FALSE]' where gNB sends 'Ignore measurement report' to UE. + +**Figure A.2.3.1-1: Example call flow for Handover preparation with extensions added to implement E2 Policy service in GREEN** + +### A.2.3.2 RIC Event Trigger Definition IE contents + +*RIC Event Trigger Definition* IE contains *E2SM-RC Event Trigger Definition Format 2* IE, which, in turn, contains RAN Parameter lists for *Associated E2 Node Info* IE and *Associated UE info* IE. + +In this example: + +1) *Associated E2 Node Info* IE is not used + +2) *Associated UE Info* IE, using RAN Parameters from clause 8.1.3, is used where the set of target UEs for the event is defined by a given slice (SST=sst1, SD=sd1) and group (IRFSP=irfsp1) + +Additional sets of target UEs may be supported using the same RAN Parameter list with different target values for SST, SD and IRFSP. These would be combined within the *Event Trigger UE Information* IE using the optional "Logical OR" flag (see clause 9.3.26). + +*RAN Parameter Testing for UE Group* (defined in 8.1.3), used to populate the *Associated UE Info* IE, are as follows: + +| RAN Parameter ID | Value type | Key flag | Value | Test condition | Semantics Description | +|------------------|------------|----------|--------|----------------|-----------------------| +| 35010 | STRUCTURE | | | | S-NSSAI | +| 35011 | ELEMENT | FALSE | sst1 | equal | >SST | +| 35012 | ELEMENT | FALSE | sd1 | equal | >SD | +| 35020 | STRUCTURE | | | | Group ID | +| 35021 | ELEMENT | FALSE | irfsp1 | equal | >IRFSP | + +### A.2.3.3 RIC Action Definition IE contents + +*E2SM-RC Action Definition Format 2* IE contains RAN Parameter lists for *Policy Condition Definition* IE and *Policy Action* IE. + +In this example the *Policy Condition Definition* IE is used to define the set of target UEs that are to be assigned a given *Policy Action* IE based on a given Serving Cell (nr-cgi1) and membership of a given Explicit UE List (HOList1). The corresponding *Policy Action* IE is used to set the measurement threshold offset for A3 RSRP measurement threshold (A3-rsrp-off1) + +Different values of NR-CGI and/or Explicit UE List ID may be used in each Policy condition in the *Policy Action* IE, each with a corresponding different Policy Action definition. + +RAN Parameters for Connected Mode Mobility Control (defined in clauses 8.5.4 and 8.1.3), used to populate the *Policy Condition Definition* IE, are as follows: + +| RAN Parameter ID | Value type | Key flag | Value | Test condition | Semantics Description | +|------------------|------------|----------|---------|----------------|----------------------------| +| 501 | LIST | | | | List of Serving cells | +| 502 | STRUCTURE | | | | >Serving cell item | +| 503 | STRUCTURE | | | | >>CHOICE Serving Cell Type | +| 504 | STRUCTURE | | | | >>>Serving NR Cell | +| 505 | ELEMENT | FALSE | nr-cgi1 | equal | >>>>Serving NR CGI | +| 35030 | ELEMENT | FALSE | HOList1 | Equal | Explicit UE List ID | + +RAN Parameters for Handover Control (defined in clause 8.5.4.1), used to populate the *Policy Action* IE, are as follows: + +| RAN Parameter ID | Value type | Key flag | Value | Semantics Description | +|------------------|------------|----------|--------------|----------------------------| +| 121 | STRUCTURE | | | A3 Event Threshold offset | +| 122 | ELEMENT | FALSE | A3-rsrp-off1 | >A3 RSRP offset (+/- x dB) | + +## Revision History + +| Date | Revision | Description | +|------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2020.09.25 | 00.00.01 | Initial instantiation of E2SM-UE | +| 2020.10.30 | 00.00.01 | Change of title to E2SM-RC | +| 2020.11.04 | 00.00.00 | Agreed baseline skeleton document with title E2SM-RC (RAN Control) | +| 2021.01.20 | 01.00.01 | Running version created with inclusion of approved sections 1-5 | +| 2021.04.28 | 01.00.02 | Addition of:<br><NOK-2021.03.25-WG3-CR-0003-Section6.1-v04> agreed WG3#92<br><NOK-2021.03.25-WG3-CR-0004-E2SM-RC-Section6.2-v04> agreed WG3#96<br><NOK-2021.04.06-WG3-CR-0005-Section7-v04> agreed WG3#95 | +| 2021.05.06 | 01.00.03 | Addition of:<br><RSYS-2021.04.13-WG3-D-E2SM-RC-REPORT-UEState_CR_v0.6> agreed WG3#96 | +| 2021.06.10 | 01.00.04 | Addition of:<br><MAV.AO-2021-05-19-WG3-CR-0001-E2SM-RC+Control+Services_v18> agreed at WG3#98<br>< NOK-2021.06.04-WG3-CR-0008-E2SM-RC rearrangement-v01> agreed at WG3#102<br>Also general editorial clean-up removing BOLD in headings, renumbering former section 8 references, adding editorial notes. | +| 2021.07.12 | 01.00.05 | Integration of Consensus CRs from Drafting Team<br><br>WG3-2021.07.09-WG3-E2SM-RC-EventTrigger-v14.docx<br>WG3-2021.06.17-WG3- E2SM-RC-REPORTService-v07.docx<br>WG3-2021.07.04.WG3-CR.E2SM-RC-Insert Control Policy Services-v17.docx | +| 2021.07.14 | 01.00.06 | Inclusion of ASN.1 and clean up | +| 2021.08.10 | 01.00 | TSC Approved | +| 2021.08.18 | 01.01.00 | V01.01 baseline including editorial corrections | +| 2021.10.13 | 01.01.01 | Incorporated WG3 Agreed CRs – <ul style="list-style-type: none"> <li>• RSYS.AO-2021.07.26-WG3-CR-0006-E2SM-RC-REPORT-CellIDInfo_v0.6.docx – Agreed in WG3#111</li> <li>• NOK.AO-2021.09.20-WG3-CR-0013-E2SM-RC-ASN1cleaning-v02.docx – Agreed in WG3#114</li> <li>• CICT-2021.09.28-WG3-CR-0006-E2SM-RC-Editorial modification-v1.docx – Agreed in WG3#116</li> <li>• NOK-2021.07.31-WG3-CR-0010-E2SM-RC-AnnexA-policy-v04.docx – Agreed in WG3#116</li> </ul> | +| 2021.11.09 | 01.01.02 | Incorporated WG3 Agreed CRs – <ul style="list-style-type: none"> <li>• MAV.AO.2021-10-19.O-RAN.WG3.E2SM-RC-v01.01.01-CR-0002 on Supported Service Style and RAN Parameter Corrections-v01.docx - Agreed in WG3#118</li> <li>• RSYS.AO-2021.10.18-WG3-CR-0008-E2SM-RC-Corrections-II_v4.docx - Agreed in WG3#119</li> <li>• NOK-2021.07.31-WG3-CR-0012-E2SM-RC-Section8.5reference8.1-v04.docx - Agreed in WG3#120</li> </ul> | +| 2021.11.16 | 01.01.03 | Incorporated WG3 Agreed CRs – <ul style="list-style-type: none"> <li>• MAV.AO-2021.11.04.WG3-CR-0005.E2SM-RC v01.01 CR on RAN Function Definition-v06.docx</li> </ul> | +| 2021.11.17 | 01.01.04 | Incorporated WG3 Agreed CRs – <ul style="list-style-type: none"> <li>• RSYS-2021.10.05-WG3-CR-0007-E2SM-RC-Corrections-I_v0.2.docx - Agreed in WG3#117</li> </ul> | + +| | | | +|------------|----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | <ul style="list-style-type: none"> <li>Editorial Cleanup</li> </ul> | +| 2021.11.22 | 01.01.05 | Copyright year modified based on WG3 voting review | +| 2022.01.19 | 01.01.06 | Fixed Footer on Cover Sheet | +| 2022.02.07 | 01.01 | Final version for November 2021 publication | +| 2022.03.11 | 01.02.01 | Incorporated WG3 Agreed CRs – <ul style="list-style-type: none"> <li>CICT.AO-2021.10.29-WG3-CR-0008-E2SM-RC-Multiple-Actions-v05.docx – Agreed in WG3#128</li> <li>RSYS.AO-2022.02.06-WG3-CR-0009-E2SM-RC-Minor Fixes_v2.docx – Agreed in WG3#131</li> </ul> | +| 2022.03.24 | 01.02.02 | Incorporated WG3 Agreed CRs – <ul style="list-style-type: none"> <li>NEC-2022.03.08-WG3-CR-0003-E2SM-RC- Wrong parameters and reference in DRB QoS Configuration -v02.docx– Agreed in WG3#136</li> <li>NOK.AO-2022.02.21-WG3-CR-0015-E2SM-RC-RAN function Definition correction-v04.docx – Agreed in WG3#136</li> <li>NOK-2022.03.14-WG3-CR-0016-E2SM-RC-RAN Parameter table corrections-v03.docx – Agreed in WG3#136</li> <li>MAV.RSYS-2022.03.09-WG3-CR-0002-E2SM-RC-Rapporteur Correction-I-v03.docx – Agreed in WG3#137</li> <li>RSYS.AO-2022.03.09-WG3-CR-0011-E2SM-RC-PolicyDecisionNewIE-v01.docx – Agreed in WG3#137</li> <li>MAV.AO-2022.03.15-WG3-CR-0009-E2SM-RC-Measurement Report Configuration-v09.docx – Agreed in WG3#137</li> </ul> | +| 2022.04.01 | 01.02.03 | Editorial corrections based on the comments during voting. <ul style="list-style-type: none"> <li>Modified upper case to lower case of “Name” in ranParameter-Name in ASN.1 in L2Parameters-RANParameter-Item</li> <li>Typo of Table name in 7.8 corrected</li> <li>Cross Reference provided for Table names in 7.8</li> </ul> | +| 2022.06.29 | 01.02 | Final version for March 2022 Publication | +| 2022.07.20 | 01.02.04 | Incorporated WG3 Agreed CRs – <ul style="list-style-type: none"> <li>NOK-2022.06.08-WG3-CR-0017-E2SM-RC-RAN Parameter ID correction-v03.docx– Agreed in WG3#154</li> </ul> | +| 2022.07.20 | 01.02.05 | Aligned to new Template | +| 2022.11.12 | 01.03.01 | Incorporated WG3 Agreed CRs – <ul style="list-style-type: none"> <li>NOK-2022.08.23-WG3-CR-0019-E2SM-RC-Policy service enhancements-v01 – Agreed in WG3#157</li> <li>INT-2022.10.28-WG3-CR-0023-E2SM-RC-enh_mMIMO_non-GoB_retrieval_rev4.docx – Agreed in WG3#164</li> <li>INT.AO-2022.10.28-WG3-CR-0025-E2SM-RC-enh_mMIMO_non-GoB_control_policy_rev3_ver3(control+genericPolicy+eventTriggerPolicy).docx – Agreed in WG3#165</li> <li>QCM-2022.09.08-WG3-CR-0001-E2SM-RC-E1AP reference correction-v02.docx – Agreed in WG3#161</li> <li>NEC-2022.10.05-WG3-CR-0007-E2SM-RC Neighbor Table Clarification v4.docx – Agreed in WG3#162</li> <li>AKA-2022.10.03-WG3-CR-0002-E2SM-RC-Neighbor Relation Information table-v02.docx – Agreed in WG3#F2F</li> <li>QCM.AO-2022.10.22-WG3-CR-0004-E2SM-RC-OnDemand Deprecate-v02.docx – Agreed in WG3#165</li> <li>QCM.AO-2022.09.08-WG3-CR-0003-E2SM-RC-RIC Query Procedure-v09.docx – Agreed in WG3#165</li> <li>MAV.AO-2022.10.05-WG3-CR-0010-E2SM-RC-UE group-based control action</li> </ul> | + +| | | | +|------------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | -v14.docx – Agreed in WG3#165 | +| 2022.11.12 | 01.03.02 | Incorporated WG3 Agreed CRs – <ul style="list-style-type: none"> <li>MAV.AO-2022.10.05-WG3-CR-0010-E2SM-RC-UE group-based control action -v16.docx – Agreed in WG3#165</li> </ul> | +| 2022.11.20 | 01.03.03 | Updated with Review comments during voting period | +| 2023.01.18 | 02.00 | Incorporated WG3 agreed Minor CR – <ul style="list-style-type: none"> <li>NOK.AO-2023.01.11-WG3-CR-0022-E2SM-RC-ASN1-correction-v03.docx</li> </ul> | +| 2023.01.18 | 02.00 | Incorporated WG3 agreed Minor CR –<br>NOK.AO-2023.01.11-WG3-CR-0022-E2SM-RC-ASN1-correction-v03.docx | +| 2023.02.08 | 03.00 | Final version for November 2022 Publication | +| 2023.06.12 | 03.00.01 | Incorporated WG3 agreed CR in F2F Feb2023 Prague –<br>NOK-2022.08.12-WG3-CR-0020-E2SM-RC-Annex A.2 Insert-Control-v05.docx | +| 2023.07.03 | 03.00.02 | Incorporated WG3 agreed CRs – <ul style="list-style-type: none"> <li>MAV-2023-04-24-WG3-CR-0011-E2SMRC v03.00 ASN1 fix for list of supported control format types-v01.docx</li> <li>MAV-2023-04-24-WG3-CR-0012-E2SMRC v03.00 UE group-based MR configuration-v02.docx</li> <li>NOK.AO-2023.02.15-WG3-CR-0023-E2SM-RC-correcting control style 8-v03.docx</li> <li>NOK-2023.03.01-WG3-CR-0024-E2SM-RC-bMRO-v04.docx</li> <li>QCM.AO-2023.06.16-WG3-CR-0005-E2SM-RC-Rapporteur Corrections-v02.docx</li> </ul> | +| 2023.07.17 | 03.00.03 | Incorporated WG3 agreed CRs – <ul style="list-style-type: none"> <li>NOV-2023.06.10-WG3-CR-0025-E2SM-RC-text-IE-name-alignment#1-v3.0.docx</li> <li>NOV-2023.06.10-WG3-CR-0026-E2SM-RC-text-IE-name-alignment#2-v2.0.docx</li> <li>NOV-2023.06.10-WG3-CR-0027-E2SM-RC-text-IE-name-alignment#3-v3.0.docx</li> </ul> | +| 2023.07.27 | 03.00.04 | Incorporated review comments during voting period | +| 2023.11.09 | 04.00.01 | Incorporated WG3 agreed CRs – <ul style="list-style-type: none"> <li>NOK.AO-2023.08.01-WG3-CR-0028-E2SM-RC-RAN Function definition stage 2-v06.docx</li> <li>QCM-2023.10.19-WG3-CR-0007-E2SM-RC-UE Identifier for RIC Query_v02.docx</li> <li>NOK-2022.01.05-WG3-CR-0014-E2SM-RC-completing control style 8-v20.docx</li> <li>NOK-2023.11.06-WG3-CR-0029-E2SM-RC-RDF extension for control-Approach 1 NBC-v1.docx</li> <li>NEC-2023.10.10-WG3-CR-0023-E2SM-RC-QoSIdentifier_IEReference_Correction-v01.docx</li> </ul> | +| 2023.11.16 | 04.00.02 | Editorial corrections implementing WG3 voting period feedback | +| 2023.11.21 | 04.00.03 | Incorporated WG3 voting period feedback | +| 2024.03.25 | 05.00.01 | Incorporated WG3 agreed CRs – <ul style="list-style-type: none"> <li>NOK-2023.11.27-WG3-CR-0031-E2SM-RC-PolicyConditionID-v02.docx</li> <li>COT-2024.01.29-WG3-CR-0002-E2SM-RC-MU-MIMO-Optimization-E2-Node-Config-v04.docx</li> <li>COT-2024.02.13-WG3-CR-0003-E2SM-RC-MU-MIMO-Optimization-UE-Context-Reporting-v02.docx</li> <li>RSYS-2024.02.16-WG3-CR-0001-E2SM-RC CellAccessBarring Parameter addition-v06.docx</li> </ul> | + +| | | | +|------------|----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | <ul style="list-style-type: none"> <li>• RSYS-2024.02.20-WG3-CR-0002-E2SM-RC UAC Barring for PLMN correction-v04.docx</li> <li>• NOK.AO-2024.03.13-WG3-CR-0032-E2SM-RC clause 3.1 and 4.3-v02.docx</li> <li>• NEC-2023.11.07-WG3-CR-0026-E2SM-RC-Neighbor to Neighbour Editorial Correction v01.docx</li> </ul> | +| 2024.03.27 | 05.00.02 | Editorial corrections during WG3 voting period | +| 2024.11.27 | 06.00.01 | Incorporated WG3 agreed CRs – <ul style="list-style-type: none"> <li>• CUC-2024.9.20-WG3-CR-0004-E2SM-RC-add descriptions of BF control and BF policy_v01.docx</li> <li>• MAV.AO-2024.10.21.WG3-CR-0013.E2SM-RC CR on CSI-RS DMRS Opt-v08.docx</li> <li>• NOK-2024.11.12-E2SM-RC-CR-0034-ErrorHandling-v02.docx</li> <li>• CUC-2024.8.19-WG3-CR-0003-E2SM-RC-Correct connected mode mobility control_v03.docx</li> <li>• COT-2024.05.24-WG3-CR-0006-E2SM-RC-MU-MIMO-Optimization-QoS-Parameters-Reporting-v02.docx</li> <li>• COT-2024.02.13-WG3-CR-0004-E2SM-RC-MU-MIMO-Optimization-Controlling-Configurations-v05.docx</li> </ul> | +| 2024.12.06 | 06.00.02 | Editorial corrections during WG3 voting period | + +--- + +## History + +| Date | Revision | Description | +|------------|----------|---------------------------------------------| +| 2021.08.10 | 01.00 | TSC Approved | +| 2022.02.07 | 01.01 | Final version for November 2021 publication | +| 2022.06.29 | 01.02 | Final version for March 2022 Publication | +| 2022.07.20 | 01.03 | Final version for July22 publication | +| 2022.11.21 | 02.00 | November 2022 Publication Withdrawn | +| 2023.02.08 | 03.00 | Final version for November 2022 Publication | +| 2023.07.31 | 04.00 | Final version for July 2023 Publication | +| 2023.11.21 | 05.00 | Final version for Nov 2023 Publication | +| 2024.04.01 | 06.00 | Final version for March 2024 Publication | +| 2024.12.09 | 07.00 | Final version for November 2024 Publication | \ No newline at end of file diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/0899ab5c06f678be5cbc5274b37a99ae_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/0899ab5c06f678be5cbc5274b37a99ae_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..450636c29db75a0fae0fb4f0267a6ffb214c03d3 --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/0899ab5c06f678be5cbc5274b37a99ae_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b9d96ddcf18ba35dacc1d6473b737539ba3b077000df36c8af576000cafd2675 +size 4540 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/71ffaefa2816d1eb4fb5ddcfa69c8b7d_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/71ffaefa2816d1eb4fb5ddcfa69c8b7d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fb26feb1cdbed5c7805b29c76ba6ef2f5b87a51b --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/71ffaefa2816d1eb4fb5ddcfa69c8b7d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:04ad47c6ebf3b31088dcfa9d3ddf69005be853247800c2e05ebe9bbe3689d33b +size 4575 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/77a065d5affee12cda1f75421d07626c_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/77a065d5affee12cda1f75421d07626c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..096c867af7ffc2a84e87fc082ca69e3f903a2be9 --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/77a065d5affee12cda1f75421d07626c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bd27ac548accf927670567157889bb849633c0a2bd2d37790a3bc7e711d0b5fb +size 4542 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/9a90a1fcc6854582dccf781d33db9879_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/9a90a1fcc6854582dccf781d33db9879_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db8c868d8b8880894ac0f636256fac3aa65ee8ab --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/9a90a1fcc6854582dccf781d33db9879_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d192cd609e84132c55fe1fe31ae8ea721f1095e2eedb6c87a6b04e6640b126ec +size 4542 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/a013218b9a93c069b973696d9e53f33c_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/a013218b9a93c069b973696d9e53f33c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0af6067d9258f5110cf783b48fea8e3d697b68c5 --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/a013218b9a93c069b973696d9e53f33c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a906fd2a686bf206b8cdd5b8428cb2aeb6c92221b1cb098a2da62b565550b33a +size 4475 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/a20ef1f299f15477d8a5bd7da26d9c5a_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/a20ef1f299f15477d8a5bd7da26d9c5a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..19eacfac8815d29b4daa9990b47e92ace53a74eb --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/a20ef1f299f15477d8a5bd7da26d9c5a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:adef441d475ec54a9e2c854b83af16e2b50835cd7945c4cc651156a19243015e +size 4555 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/a80871b65d3ca1bf1bf5b8095d71050e_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/a80871b65d3ca1bf1bf5b8095d71050e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..84acbecde5e4d8af268951d4adcf5ff045fd29a0 --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/a80871b65d3ca1bf1bf5b8095d71050e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ca1be63c5eaa785156d8db8a8f4543d9748fe7866de89831e42aba0f4ca6ae1 +size 4563 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/b857dbac86b210b051171d4dbaa05250_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/b857dbac86b210b051171d4dbaa05250_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..728308d6c4ad2b38f3380dc3b48c90ce855ca53b --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/b857dbac86b210b051171d4dbaa05250_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5f486653be729590b142b2727d1b82a9a16bef23e6864f26b20a8890f4e0e137 +size 4536 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/b94d56e5784f9ceb14c26b1eab8cdc6d_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/b94d56e5784f9ceb14c26b1eab8cdc6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0489000126a97a493451f775c549045d93351162 --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/b94d56e5784f9ceb14c26b1eab8cdc6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7648d6e983dc7f59018fb0b1ad333b60adef9d0df97503d244bf74b4964930e0 +size 4576 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/c4d1d5e473ebe317a9325d3f76176497_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/c4d1d5e473ebe317a9325d3f76176497_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bd5685a9c0819ae917c9fea1f7e1366522f22214 --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/c4d1d5e473ebe317a9325d3f76176497_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:53cfdcfe6c625381d790454add0163eb4e5755172cbaff07c2e06e5c730a9f70 +size 4596 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/f588aacc936ec21c1d891b760d327b9a_img.jpg b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/f588aacc936ec21c1d891b760d327b9a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1d79bccc7160396f80c2338cf98ce55d5df3e3d5 --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/f588aacc936ec21c1d891b760d327b9a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6b1797c2c64f2bd8d0643e65c0ad4d3b160da09e654436e413e03674a75ae675 +size 4538 diff --git a/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/raw.md b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..08ed83ae6b32bfb71bc4c15daa7d398c2ee325f8 --- /dev/null +++ b/marked/WG3/ORAN-WG3.E2SM-NI-v01.00/raw.md @@ -0,0 +1,1990 @@ + + +# **O-RAN Working Group 3 Near-Real-time RAN Intelligent Controller E2 Service Model (E2SM), RAN Function Network Interface (NI)** + +--- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Working Group 3 Near-Real-time RAN Intelligent Controller E2 Service Model (E2SM), RAN Function Network Interface (NI)** --- + +# Revision History + +| Date | Revision | Author | Description | +|------------|-----------|--------------------------------------------|----------------------------------------------------| +| 2020.01.22 | 01.00.00 | Alistair URIE,<br>Paul STEPHENS<br>(Nokia) | Specification renamed v01.00.00 for approval | +| 2020.01.29 | 0.1.00.00 | Alistair URIE,<br>Paul STEPHENS<br>(Nokia) | Corrected based on remarks during electronic vote. | + +"© 2019. 3GPP™ TSs and TRs are the property of ARIB, ATIS, CCSA, ETSI, TSDSI, TTA and TTC who jointly own the copyright in them. They are subject to further modifications and are therefore provided to you "as is" for information purposes only. Further use is strictly prohibited." + +"© 2020. 3GPP™ TSs and TRs are the property of ARIB, ATIS, CCSA, ETSI, TSDSI, TTA and TTC who jointly own the copyright in them. They are subject to further modifications and are therefore provided to you "as is" for information purposes only. Further use is strictly prohibited." + +# Contents + +| | | | | +|----|-------------------------------------------------------------------------------------|--|----| +| 1 | | | | +| 2 | Revision History ..... | | 2 | +| 3 | 1 Scope ..... | | 5 | +| 4 | 2 References ..... | | 5 | +| 5 | 3 Definitions and Abbreviations ..... | | 6 | +| 6 | 3.1 Definitions ..... | | 6 | +| 7 | 3.2 Abbreviations ..... | | 6 | +| 8 | 4 General ..... | | 7 | +| 9 | 4.1 Procedure Specification Principles ..... | | 7 | +| 10 | 4.2 Forwards and Backwards Compatibility ..... | | 7 | +| 11 | 4.3 Specification Notations ..... | | 7 | +| 12 | 4.3 Identifiers ..... | | 8 | +| 13 | 5 E2SM services ..... | | 9 | +| 14 | 6 RAN Function Service Model Description ..... | | 10 | +| 15 | 6.1 RAN Function Overview ..... | | 10 | +| 16 | 6.2 RAN Function exposure services ..... | | 10 | +| 17 | 6.2.1 <b>REPORT</b> service ..... | | 10 | +| 18 | 6.2.2 <b>INSERT</b> service ..... | | 10 | +| 19 | 6.2.3 <b>CONTROL</b> service ..... | | 10 | +| 20 | 6.2.4 <b>POLICY</b> service ..... | | 10 | +| 21 | 7 RAN Function Description ..... | | 11 | +| 22 | 7.1 Description ..... | | 11 | +| 23 | 7.2 RAN Function name ..... | | 11 | +| 24 | 7.3 Event trigger definition styles ..... | | 11 | +| 25 | 7.3.1 RIC Event trigger definition IE style list ..... | | 11 | +| 26 | 7.3.2 <i>RIC Event trigger definition</i> IE style 1: Interface Message Event ..... | | 11 | +| 27 | 7.4 Supported RIC <b>REPORT</b> Service styles ..... | | 12 | +| 28 | 7.4.1 <b>REPORT</b> Service style list ..... | | 12 | +| 29 | 7.4.2 <b>REPORT</b> Service Style 1: Complete message ..... | | 12 | +| 30 | 7.4.3 <b>REPORT</b> Service Style 2: Partial message ..... | | 12 | +| 31 | 7.5 Supported RIC <b>INSERT</b> Service styles ..... | | 13 | +| 32 | 7.5.1 RIC <b>INSERT</b> Service style list ..... | | 13 | +| 33 | 7.5.2 <b>INSERT</b> Service Style 1: Complete message ..... | | 13 | +| 34 | 7.6 Supported RIC <b>CONTROL</b> Service styles ..... | | 14 | +| 35 | 7.6.1 RIC <b>CONTROL</b> Service style list ..... | | 14 | +| 36 | 7.6.2 <b>CONTROL</b> Service Style 1: Complete message ..... | | 14 | +| 37 | 7.7 Supported RIC <b>POLICY</b> Service styles ..... | | 15 | +| 38 | 7.7.1 RIC <b>POLICY</b> Service style list ..... | | 15 | +| 39 | 7.7.2 <b>POLICY</b> Service style 1: Message admission ..... | | 15 | +| 40 | 7.8 Supported RIC Service Styles and E2SM IE Formats ..... | | 16 | +| 41 | 8 Elements for E2SM Service Model ..... | | 17 | +| 42 | 8.1 General ..... | | 17 | +| 43 | 8.2 Message Functional Definition and Content ..... | | 17 | +| 44 | 8.2.1 Messages for RIC Functional procedures ..... | | 17 | +| 45 | 8.2.2 Messages for RIC Global Procedures ..... | | 22 | +| 46 | 8.3 Information Element definitions ..... | | 24 | +| 47 | 8.3.1 General ..... | | 24 | +| 48 | 8.3.2 RAN Function name ..... | | 25 | +| 49 | 8.3.3 RIC Style Type ..... | | 25 | +| 50 | 8.3.4 RIC Style Name ..... | | 25 | +| 51 | 8.3.5 RIC Format Type ..... | | 25 | +| 52 | 8.3.6 RAN Parameter Type ..... | | 26 | +| 53 | 8.3.7 RAN Parameter ID ..... | | 26 | + +| | | | | +|----|-------------|-------------------------------------------------------------------|----| +| 1 | 8.3.8 | RAN Parameter Test Condition ..... | 26 | +| 2 | 8.3.9 | RAN Parameter Value..... | 26 | +| 3 | 8.3.10 | RAN Parameter Name..... | 27 | +| 4 | 8.3.11 | RAN Call process ID..... | 27 | +| 5 | 8.3.12 | RIC Control Message Priority ..... | 27 | +| 6 | 8.3.13 | reserved ..... | 27 | +| 7 | 8.3.14 | RAN UE Group ID..... | 27 | +| 8 | 8.3.15 | RAN UE Group Definition ..... | 28 | +| 9 | 8.3.16 | RAN Imperative Policy ..... | 28 | +| 10 | 8.3.17 | reserved ..... | 28 | +| 11 | 8.3.18 | reserved ..... | 28 | +| 12 | 8.3.19 | reserved ..... | 28 | +| 13 | 8.3.20 | reserved ..... | 28 | +| 14 | 8.3.21 | Network Interface Type ..... | 28 | +| 15 | 8.3.22 | Network Interface Identifier..... | 29 | +| 16 | 8.3.23 | Network Interface Direction..... | 29 | +| 17 | 8.3.24 | Network Interface Timestamp..... | 30 | +| 18 | 8.3.25 | Network Interface Message Type..... | 30 | +| 19 | 8.3.26 | Message Protocol IE Identifier..... | 30 | +| 20 | 8.3.27 | Message Protocol IE Test Condition..... | 31 | +| 21 | 8.3.28 | Message Protocol IE Value..... | 31 | +| 22 | 8.3.29 | Network Interface Message..... | 31 | +| 23 | 8.4 | Information Element Abstract Syntax (with ASN.1)..... | 32 | +| 24 | 8.4.1 | General ..... | 32 | +| 25 | 8.4.2 | Information Element definitions ..... | 32 | +| 26 | 8.5 | Message transfer syntax..... | 40 | +| 27 | 9 | Handling of Unknown, Unforeseen and Erroneous Protocol Data ..... | 40 | +| 28 | Annex A: | Further information on RAN Function Network Interface ..... | 40 | +| 29 | A.1 | Background information ..... | 40 | +| 30 | A.2 | X2 Network Interface ..... | 41 | +| 31 | A.2.1 | Message Admission policy handling..... | 41 | +| 32 | Annex ZZZ : | O-RAN Adopter License Agreement ..... | 42 | +| 33 | Section 1: | DEFINITIONS ..... | 42 | +| 34 | Section 2: | COPYRIGHT LICENSE ..... | 42 | +| 35 | Section 3: | FRAND LICENSE ..... | 42 | +| 36 | Section 4: | TERM AND TERMINATION ..... | 43 | +| 37 | Section 5: | CONFIDENTIALITY ..... | 43 | +| 38 | Section 6: | INDEMNIFICATION ..... | 43 | +| 39 | Section 7: | LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 44 | +| 40 | Section 8: | ASSIGNMENT ..... | 44 | +| 41 | Section 9: | THIRD-PARTY BENEFICIARY RIGHTS ..... | 44 | +| 42 | Section 10: | BINDING ON AFFILIATES ..... | 44 | +| 43 | Section 11: | GENERAL..... | 44 | +| 44 | | | | +| 45 | | | | +| 46 | | | | + +1 +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 +16 +17 +18 +19 +20 +21 +22 +23 +24 +25 +26 +27 +28 +29 +30 +31 +32 +33 +34 +35 +36 +37 +38 +39 +40 +41 + +# 1 Scope + +This Technical Specification has been produced by the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +The present document specifies the E2 Service Model (E2SM) “Network Interface” (NI) for the RAN function handling the Network Interfaces in an E2 Node. Further information on this RAN function is described in Annex A. + +# 2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document. + +[1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. + +[2] O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, Architecture & E2 General Aspects and Principles (E2GAP) + +[3] ORAN WG3, O-RAN Working Group 3, Near-Real-time RAN Intelligent Controller, E2 Application Protocol (E2AP). + +[4] 3GPP TR 25.921: "Guidelines and principles for protocol description and error handling". + +[5] ITU-T Recommendation X.680 (2002-07): "Information technology – Abstract Syntax Notation One (ASN.1): Specification of basic notation". + +[6] ITU-T Recommendation X.681 (2002-07): "Information technology – Abstract Syntax Notation One (ASN.1): Information object specification". + +[7] ITU-T Recommendation X.691 (2002-07): "Information technology - ASN.1 encoding rules - Specification of Packed Encoding Rules (PER) " + +[8] reserved + +[9] reserved + +[10] 3GPP 36.413, Evolved Universal Terrestrial Radio Access Network (E-UTRAN); S1 Application Protocol (S1AP) + +[11] 3GPP 36.423, Evolved Universal Terrestrial Radio Access Network (E-UTRAN); X2 application protocol (X2AP) + +- [12] 3GPP 38.413, NG-RAN; NG Application Protocol (NGAP) +- [13] 3GPP 38.423, NG-RAN; Xn application protocol (XnAP) +- [14] F1 interface, NG-RAN; F1 application protocol (F1AP), 3GPP 38.473 +- [15] E1 interface, NG-RAN; E1 Application Protocol (E1AP), 3GPP 38.463 + +# 3 Definitions and Abbreviations + +## 3.1 Definitions + +For the purposes of the present document, the following terms and definitions apply. + +**E2 Node:** as defined in E2GAP [2]. + +**RAN Function:** as defined in E2GAP [2] + +**E2 Service Model:** The description of the Services exposed by a specific RAN function within an E2 node over the E2 interface towards the Near-RT RIC. + +**Network Interface:** Network interface used to carry a network protocol between network nodes + +## 3.2 Abbreviations + +For the purposes of the present document, the following abbreviations apply. + +| | | +|-------------|-------------------------------------------| +| O-CU | O-RAN Central Unit | +| O-CU-CP | O-RAN Central Unit – Control Plane | +| O-CU-UP | O-RAN Central Unit – User Plane | +| O-DU | O-RAN Distributed Unit | +| Near-RT RIC | Near-real-time RAN Intelligent Controller | + +# 4 General + +## 4.1 Procedure Specification Principles + +The principle for specifying the procedure logic is to specify the functional behaviour of the terminating node exactly and completely. Any rule that specifies the behaviour of the originating node shall be possible to be verified with information that is visible within the system. + +The following specification principles have been applied for the procedure text in clause 8: + +- The procedure text discriminates between: + +### 1) Functionality which "shall" be executed. + +The procedure text indicates that the receiving node "shall" perform a certain function Y under a certain condition. If the receiving node supports procedure X but cannot perform functionality Y requested in the REQUEST message of a Class 1 EP, the receiving node shall respond with the message used to report unsuccessful outcome for this procedure, containing an appropriate cause value. + +### 2) Functionality which "shall, if supported" be executed. + +The procedure text indicates that the receiving node "shall, if supported," perform a certain function Y under a certain condition. If the receiving node supports procedure X, but does not support functionality Y, the receiving node shall proceed with the execution of the EP, possibly informing the requesting node about the not supported functionality. + +- Any required inclusion of an optional IE in a response message is explicitly indicated in the procedure text. If the procedure text does not explicitly indicate that an optional IE shall be included in a response message, the optional IE shall not be included. For requirements on including *Criticality Diagnostics* IE, see clause 10. + +## 4.2 Forwards and Backwards Compatibility + +The forwards and backwards compatibility of the protocol is assured by a mechanism where all current and future messages, and IEs or groups of related IEs, include ID and criticality fields that are coded in a standard format that will not be changed in the future. These parts can always be decoded regardless of the standard version. + +## 4.3 Specification Notations + +For the purposes of the present document, the following notations apply: + +| | | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Service | when referring to a Service in the specification the <b>SERVICE NAME</b> is written with upper case characters and in bold followed by the word "service", e.g. <b>REPORT</b> service. | +| Procedure | When referring to an elementary procedure in the specification the Procedure Name is written with the first letters in each word in upper case characters followed by the word "procedure", e.g. Handover Preparation procedure. | +| Message | When referring to a message in the specification the MESSAGE NAME is written with all letters in upper case characters followed by the word "message", e.g. HANDOVER REQUEST message. | +| IE | When referring to an information element (IE) in the specification the <i>Information Element Name</i> is written with the first letters in each word in upper case characters and all letters in Italic font followed by the abbreviation "IE", e.g. <i>E-RAB ID</i> IE. | +| Value of an IE | When referring to the value of an information element (IE) in the specification the "Value" is written as it is specified in the specification enclosed by quotation marks, e.g. "Value". | + +## 4.3 Identifiers + +For the purposes of the present document, the following identifiers are defined: + +| | | +|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Style Type | The identifier used to nominate a specific approach or Style used to exposing a given RIC Service (REPORT, INSERT, CONTROL and POLICY). The same E2SM may support more than one Style for each RIC Service. | +| Format Type | The identifier used to nominate a specific formatting approach used to encode one of the E2AP IEs defined in this E2SM. The same E2SM may support more than one encoding Formats for each E2AP IE and each E2AP IE message encoding Format may be used by one or more RIC Service Styles. | + +# 5 E2SM services + +As defined in E2 General Aspects and Principles [2], a given RAN Function offers a set of services to be exposed over the E2 (**REPORT**, **INSERT**, **CONTROL** and/or **POLICY**) using E2AP [3] defined procedures. Each of the E2AP Procedures listed in table 5-1 contains specific E2 Node RAN Function dependent Information Elements (IEs). + +**Table 5-1: Relationship RAN Function specific E2AP Information elements and E2AP Procedures** + +| RAN Function specific E2AP Information Elements | E2AP Information Element reference | Related E2AP Procedures | +|-------------------------------------------------|------------------------------------|--------------------------------| +| <i>RIC Event Trigger Definition IE</i> | E2AP [3] section 9.2.9 | RIC Subscription | +| <i>RIC Action Definition IE</i> | E2AP [3] section 9.2.12 | RIC Subscription | +| <i>RIC Indication Header IE</i> | E2AP [3] section 9.2.17 | RIC Indication | +| <i>RIC Indication Message IE</i> | E2AP [3] section 9.2.16 | RIC Indication | +| <i>RIC Call Process ID IE</i> | E2AP [3] section 9.2.18 | RIC Indication<br>RIC Control | +| <i>RIC Control Header IE</i> | E2AP [3] section 9.2.20 | RIC Control | +| <i>RIC Control Message IE</i> | E2AP [3] section 9.2.19 | RIC Control | +| <i>RIC Control Outcome IE</i> | E2AP [3] section 9.2.25 | RIC Control | +| <i>RAN Function Definition IE</i> | E2AP [3] section 9.2.23 | E2 Setup<br>RIC Service Update | + +All of these RAN Function specific E2AP IEs are defined in E2AP [3] as “OCTET STRING”. + +The purpose of this specification is to define the contents of these fields for the specific RAN function “NI” (Network Interface). + +# 6 RAN Function Service Model Description + +## 6.1 RAN Function Overview + +For the purposed of this E2 Service Model, E2SM-NI, the E2 Node terminating the E2 Interface is assumed to host the RAN Function NI “Network Interface” which performs the following functionalities: + +- Exposure of Network Interfaces +- Modification of both incoming and outgoing network interface message contents +- Execution of policies that may result in change of network behavior + +This E2SM specification provides a set of RAN Function exposure services described in clause 6.2 and has been prepared with the assumption that the same E2SM may be used to describe either a single RAN Function handling all Network Interfaces or more than one RAN function with each one handling a subset of the Network Interfaces terminated on the E2 Node. + +## 6.2 RAN Function exposure services + +### 6.2.1 REPORT service + +The “Network Interface” RAN Function provides selective support of the following **REPORT** services: + +- Copy of Complete message with header providing network interface type, identifier and direction with optional network interface timestamp +- Copy of Partial message selected by target message protocol IE identifier with with header providing network interface type, identifier, direction and message type with optional network interface timestamp + +These services may be initiated according to: + +- Target network interface type, identifier, direction and message type along with the presence of a sequence of one or more message protocol IE identifiers with optional message protocol IE contents selection rules. + +### 6.2.2 INSERT service + +The “Network Interface” RAN Function provides selective support of the following **INSERT** services: + +- Forwarding of Complete message with header providing network interface type, identifier and direction with optional network interface timestamp + +This service may be initiated according to: + +- Target network interface type, identifier and direction, message type and presence of a sequence of one or more message protocol IE identifiers with optional message protocol IE contents selection rules. + +### 6.2.3 CONTROL service + +The “Network Interface” RAN Function provides selective support of the following **CONTROL** services: + +- Injection of Complete message with header providing target network interface type, identifier and direction and optional RIC Control Message Priority + +### 6.2.4 POLICY service + +The “Network Interface” RAN Function provides selective support of the following **POLICY** services: + +- Handling of Message Admission process according to a list of parameters to be applied to different RAN UE groups + +This service may be initiated according to: + +- Target network interface type, identifier and direction, message type and presence of a sequence of one or more message protocol IE identifiers with optional message protocol IE contents selection rules. + +# 7 RAN Function Description + +## 7.1 Description + +The E2AP [3] procedures E2 Setup and RIC Service Update are used to transport the RAN Function Description. + +For the specific RAN Function, the *RAN Function Description* IE shall report the following information: + +- RAN Function name along with associated information on E2SM definition +- Event trigger styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **REPORT** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **INSERT** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **CONTROL** Service styles list along with the corresponding encoding type for each associated E2AP IE. +- RIC **POLICY** Service styles list along with the corresponding encoding type for each associated E2AP IE. + +## 7.2 RAN Function name + +RAN Function Short Name “ORAN-E2SM-NI” + +RAN Function name description “Network Interface” + +RAN Function Instance, required when and if E2 Node exposes more than one instance of a RAN Function based on this E2SM. + +## 7.3 Event trigger definition styles + +### 7.3.1 RIC Event trigger definition IE style list + +| RIC Style Type | Style Name | Supported RIC Service Style | | | Style Description | +|----------------|-------------------------|-----------------------------|--------|--------|----------------------------------------------------------------------------| +| | | Report | Insert | Policy | | +| 1 | Interface Message Event | 1, 2 | 1 | 1 | <i>RIC Event trigger definition</i> IE based on arrival of defined message | + +### 7.3.2 *RIC Event trigger definition* IE style 1: Interface Message Event + +This *RIC Event Trigger Definition* IE style is used to detect a specific interface message event in E2 Node RAN Function based on specified target Network Interface Type, Network Interface Identifier, Network Interface Direction, Network Interface Message Type, Message Protocol IE Identifier, Message Protocol IE Test Condition and Message Protocol IE Test Value. + +This *RIC Event Trigger Definition* IE style uses *RIC Event Trigger Definition* IE Format 1 (8.2.1.1.1) + +## 7.4 Supported RIC **REPORT** Service styles + +### 7.4.1 **REPORT** Service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|------------------|-----------------------------------------------------------------| +| 1 | Complete message | Used to send copy of complete message from E2 Node RAN Function | +| 2 | Partial message | Used to send copy of part of message from E2 Node RAN Function | + +### 7.4.2 **REPORT** Service Style 1: Complete message + +#### 7.4.2.1 **REPORT** Service Style description + +This **REPORT** Service style provides a copy of a complete network interface message with the network interface specific encoded message carried as a transparent container with an associated header providing information on the target Network Interface Type, Network Interface Identifier, Network Interface Direction and optional Network Interface Timestamp. The addition of optional information time stamp in the Indication Header is controlled using the associated RIC Action Parameter + +#### 7.4.2.2 **REPORT** Service *RIC Action Definition* IE contents + +This **REPORT** Service style uses the following RAN parameters with *RIC Action Definition* IE Format 1 (8.2.1.1.1) where AddTimestamp is used to request the inclusion of optional Network Interface Timestamp information in *RIC Indication header* IE: + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter description | +|------------------|--------------------|--------------------|------------------------------------------------------------------------| +| 1 | AddTimestamp | BOOLEAN | TRUE=Use optional Network Interface Timestamp in RIC Indication Header | + +#### 7.4.2.3 **REPORT** Service *RIC Indication header* IE contents + +**REPORT** Service *RIC Indication Header* IE contains the Network Interface Type, Network Interface Identifier, Network Interface Direction and optional Network Interface Timestamp. + +This **REPORT** Service style uses *RIC Indication header* IE Format 1 (8.2.1.3.1) + +#### 7.4.2.4 **REPORT** Service *RIC Indication message* IE contents + +**REPORT** Service *RIC Indication message* IE contains contains a transparent container used to carry the complete message with contents defined by the specific network interface specification. + +This **REPORT** Service style uses *RIC Indication message* IE Format 1 (8.2.1.4.1) + +### 7.4.3 **REPORT** Service Style 2: Partial message + +#### 7.4.3.1 **REPORT** Service Style description + +This **REPORT** Service style provides a copy of a specific information element extracted from a network interface message with the network interface specific encoded message carried as a transparent container associated with an indication header providing information on the target Network Interface Type, Network Interface Identifier, Network Interface Direction, Network Interface Message Type and optional Network Interface Timestamp. The addition of optional Network Interface Timestamp in the Indication Header and the rules for extracting the part of the message are controlled using the associated RIC Action Parameter + +#### 7.4.3.2 REPORT Service RIC Action Definition IE contents + +This **REPORT** Service style uses the following RAN parameters with *RIC Action Definition* IE Format 1 (8.2.1.1.1) where AddTimestamp is used to request the inclusion of optional Timestamp information in *RIC Indication header* IE and Target Protocol IE Identifier is used to specify the required IE to be copied from the message. + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter description | +|------------------|-------------------------------|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | AddTimestamp | BOOLEAN | TRUE=Use optional Network Interface Timestamp in RIC Indication Header | +| 2 | Target Protocol IE Identifier | INTEGER | Identifies the target Protocol IE identifier to be copied from the message and sent in Indication Message IE. Specified in terms of Protocol IE ID using the definition of the specific network interface type | + +#### 7.4.3.3 REPORT Service RIC Indication header IE contents + +**REPORT** Service *RIC Indication Header* IE contains the Network Interface Type, Network Interface Identifier, Network Interface Direction and optional Network Interface Timestamp. + +This **REPORT** Service style uses *RIC Indication header* IE Format 1 (8.2.1.3.1) + +#### 7.4.3.4 REPORT Service RIC Indication message IE contents + +**REPORT** Service *RIC Indication message* IE contains a transparent container used to carry the extracted part of the message with contents defined by the specific network interface specification. + +This **REPORT** Service style uses *RIC Indication message* IE Format 1 (8.2.1.4.1) + +## 7.5 Supported RIC INSERT Service styles + +### 7.5.1 RIC INSERT Service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|------------------|--------------------------------------------------------------| +| 1 | Complete message | Used to forward a complete message from E2 Node RAN function | + +### 7.5.2 INSERT Service Style 1: Complete message + +#### 7.5.2.1 INSERT Service Style description + +This **INSERT** Service style provides the forwarding of a complete network interface message with the network interface specific encoded message carried as a transparent container with an associated header providing information on the target Network Interface Type, Network Interface Identifier, Network Interface Direction and optional Network Interface Timestamp. The addition of optional information timestamp in the Indication Header is controlled using the associated RIC Action Parameter + +#### 7.5.2.2 INSERT Service RIC Action Definition IE contents + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter description | +|------------------|--------------------|--------------------|-----------------------------------------------------------------------| +| 1 | AddTimestamp | BOOLEAN | TRUE=Use optional <i>Timestamp</i> IE in <i>RIC Indication Header</i> | + +#### 7.5.2.3 INSERT Service RIC Indication header IE contents + +**INSERT** Service *RIC Indication Header* IE contains the following information Network Interface Type, Network Interface Identifier, Network Interface Direction and optional Network Interface Timestamp. + +This **INSERT** Service style uses *RIC Indication header* Format 1 (8.2.1.3.1) + +#### 7.5.2.4 INSERT Service RIC Indication message IE contents + +**INSERT** Service *RIC Indication message* IE contains a transparent container used to carry the complete message with contents defined by the specific network interface specification. + +This **INSERT** Service style uses *RIC Indication message* IE Format 1 (8.2.1.4.1) + +#### 7.5.2.5 INSERT Service RIC Call Process ID IE contents + +*RIC Call Process ID* contains identifier used by the RAN Function to match the outgoing **INSERT** Service message with a subsequent incoming **CONTROL** Service message. + +This **INSERT** Service style uses *RIC Call Process ID* type 1 (8.2.1.5.1) to carry a local RAN Function assigned call process instance sequence number that, under normal traffic conditions, shall be unique to the given RAN function instance for a period of 1 hour. + +## 7.6 Supported RIC CONTROL Service styles + +### 7.6.1 RIC CONTROL Service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|------------------|-------------------------------------------------------------| +| 1 | Complete message | Used to inject a complete message into E2 Node RAN Function | + +### 7.6.2 CONTROL Service Style 1: Complete message + +#### 7.6.2.1 CONTROL Service Style description + +This **CONTROL** Service style provides the injection of a complete message carried as a transparent container with an associated header providing the target Network Interface Type, Network Interface Identifier and Network Interface Direction along with an option RIC Control Message Priority. + +The RIC Control Message Priority shall be used by the RAN Function to order the queuing of incoming Control messages and E2 Node originated messages on the same network interface. The following rules shall apply: + +- Control messages with higher priority shall be handled prior to Control messages with lower priority +- Positive RIC Control Message Priority implies a priority over E2 Node originated messages +- Negative priority implies that E2 Node originated messages shall be sent prior to incoming Control messages. +- Default Control priority = 0 implies Control messages shall be treated with the same priority as E2 Node originated messages + +#### 7.6.2.2 CONTROL Service RIC Control Header IE contents + +*RIC Control Header* contains the following information Network Interface Type, Network Interface Identifier and Network Interface Direction and the optional RIC Control Message Priority. This **CONTROL** style uses *RIC Control Header* Format 1 (8.2.1.6.1) + +#### 7.6.2.3 CONTROL Service RIC Control Message IE contents + +*RIC Control Message* contains a transparent container used to carry the complete message with contents defined by the specific network interface specification. + +This **CONTROL** style uses *RIC Control Message* Format 1 (8.2.1.7.1) + +#### 7.6.2.4 CONTROL Service RIC Call Process ID IE contents + +**CONTROL** Service *RIC Call Process ID* contains identifier used by the Near-RT RIC to allow the RAN Function to match the outgoing **INSERT** Service message with a subsequent incoming **CONTROL** Service message. + +This **CONTROL** Service style uses *RIC Call Process ID* IE Format 1 (8.2.1.5.1) + +#### 7.6.2.5 CONTROL Service RIC Control Outcome IE contents + +*RIC Control Outcome* IE contains a transparent container used to carry the outcome of executing the RIC Control Request. In particular this message reports on the time that the RIC Control Request was received by the RAN Function and the time that the network interface message contained in the RIC Control Message IE was transmitted by the RAN function over the specified network interface. The difference between these two timestamps reflects both internal processes delays and the impact of the requested RIC Control Message Priority with respect to E2 Node originated network interface messages + +This **CONTROL** style uses *RIC Control Outcome* Format 1 (8.2.1.8.1) + +| RAN Parameter ID | RAN Parameter Name | RAN Parameter Type | Parameter description | +|------------------|---------------------|---------------------------|-----------------------------------------------------------------------| +| 1 | ReceivedTimestamp | NetworkInterfaceTimestamp | Time RIC Control Request received by RAN Function | +| 2 | TransmitteTimestamp | NetworkInterfaceTimestamp | Time RIC Control Request message contents transmitted by RAN Function | + +## 7.7 Supported RIC POLICY Service styles + +### 7.7.1 RIC POLICY Service style list + +| RIC Style Type | Style Name | Style Description | +|----------------|-------------------|------------------------------------------------------------------------------------------------------------------| +| 1 | Message Admission | Used to control the execution of the Message Admission process for an incoming message into E2 Node RAN Function | + +### 7.7.2 POLICY Service style 1: Message admission + +#### 7.7.2.1 POLICY Service style description + +This **POLICY** Service style is used to provide an Imperative Policy to control execution of a Message Admission process for an incoming message of type “REQUEST” received by the specific E2 Node RAN Function. The associated *Action Definition* IE provides the rules to be executed as an Imperative E2 Policy with different parameters assigned to each RAN UE Group. + +A positive outcome of the Imperative policy results in the incoming message being forwarded to the E2 Node without modification. + +A negative outcome of the Imperative policy results in the creation of an appropriate request rejection message as defined in Annex A.2.1 + +#### 7.7.2.2 **POLICY** Service *RIC Action Definition* IE contents + +This **POLICY** Service style uses *RIC Action Definition* IE Format 2 (8.2.1.1.2) where: + +- RAN UE group is described in terms of a list of test conditions using RAN Parameters. A given UE is to be considered to be assigned to a specific RAN UE Group when all test conditions are met. RAN UE Group ID = 0 is used for the default case and so applies to any UE that is not assigned to any other RAN UE Group +- Imperative E2 Policy is encoded in terms of a list of specific RAN Parameters and shall be applied to any UE within a given RAN UE Group. The default UE policy corresponding to the default behavior of the RAN function without an active Imperative E2 Policy is used for UE assigned to RAN UE Group ID = 0 + +## 7.8 Supported RIC Service Styles and E2SM IE Formats + +Table 7.8-1 and 7.8-2 provide a summary of the E2SM IE Formats defined to support the set of RIC Event Triggers and RIC Service Styles defined in this E2SM specification. + +**Table 7.8-1: Summary of the E2SM IE encoding Formats defined to support the set of RIC Event Trigger styles** + +| RIC Service and Style | Event Trigger Definition Format | +|-----------------------|---------------------------------| +| <b>Event Trigger</b> | | +| Style 1 | 1 | +| | | +| | | + +**Table 7.8-1: Summary of the E2SM IE encoding Formats defined to support the set of RIC Service Styles** + +| RIC Service and Style | Action Definition Format | Indication header Format | Indication message Format | Call Process ID Format | Control header Format | Control message Format | +|-----------------------|--------------------------|--------------------------|---------------------------|------------------------|-----------------------|------------------------| +| <b>REPORT</b> | | | | | | | +| Style 1 | 1 | 1 | 1 | | | | +| Style 2 | 1 | 1 | 1 | | | | +| | | | | | | | +| <b>INSERT</b> | | | | | | | +| Style 1 | 1 | 1 | 1 | 1 | | | +| | | | | | | | +| <b>CONTROL</b> | | | | | | | +| Style 1 | | | | 1 | 1 | 1 | +| | | | | | | | +| <b>POLICY</b> | | | | | | | +| Style 1 | 2 | | | | | | +| | | | | | | | + +# 8 Elements for E2SM Service Model + +## 8.1 General + +Sub clause 8.2 describes the structure of the information elements as required for the E2SM-NI Service Model in tabular format. Sub clause 8.3 presents the individual information elements. Sub clause 8.4 provides the corresponding ASN.1 definition of each information element. + +The following attributes are used for the tabular description of the messages and information elements: + +NOTE: The messages have been defined in accordance to the guidelines specified in 3GPP TR 25.921 [4]. + +## 8.2 Message Functional Definition and Content + +### 8.2.1 Messages for RIC Functional procedures + +#### 8.2.1.1 RIC Event Trigger Definition IE + +This information element is part of the RIC SUBSCRIPTION REQUEST message sent by the Near-RT RIC to a E2 Node and is required for event triggers used to initiate REPORT, INSERT and POLICY actions. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE Format | | | | | +| >E2SM-NI Event Trigger Definition Format 1 | M | | 8.2.1.1.1 | | + +##### 8.2.1.1.1 E2SM-NI Event Trigger Definition Format 1 + +This RIC Event Trigger Definition style allows to select a specific target using: + +- Network Interface Type IE used to select a specific interface type, +- Network Interface Identifier used to select a specific interface instance, +- Network Interface Direction used to select a specific interface direction (incoming or outgoing), +- Network Interface Message Type used to select a specific message on the interface, +- Message Protocol IE Identifier used to select a specific protocol element in the selected message, +- Message Protocol IE Test Condition and Message Protocol IE Test Value are used to test if the selected protocol element meets a specific test condition where the trigger condition applies when and only if all of the test conditions are TRUE (i.e. logical AND of each test condition). + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------|----------|-------------------------------------|-----------------------|----------------------------------------------------------------| +| Network Interface Type | M | | 8.3.21 | | +| Network Interface Identifier | O | | 8.3.22 | "Any" instance to be used if absent | +| Network Interface Direction | O | | 8.3.23 | "Both" directions to be used if absent | +| Network Interface Message Type | O | | 8.3.25 | "Any" message type to be used if absent | +| Sequence of Message Protocol Tests | | 0.. <maxof Interface Protocol Test> | | "Any" message if zero message protocol tests in list | +| >Message Protocol IE ID | M | | 8.3.26 | Protocol IE ID presence in message if test condition is absent | +| >Message Protocol IE Test condition | O | | 8.3.27 | | +| >Message Protocol IE Value | O | | 8.3.28 | Shall be included if test condition is present | + +| Range bound | Explanation | +|-------------------------------|----------------------------------------------------------------------------------------------------------------------| +| maxof Interface Protocol Test | Maximum no. of Network Interface Protocol Test in event trigger definition supported by RAN Function. Value is <15>. | + +#### 8.2.1.2 RIC Action Definition IE + +This information element is part of the RIC SUBSCRIPTION REQUEST message sent by the Near-RT RIC to a E2 Node and is required for POLICY actions and optional for REPORT and INSERT actions. This information element provides addition information for the nominated Action (Report, Insert, Policy) + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------|----------|-------|-----------------------|-----------------------| +| RIC Style Type | M | | 8.3.3 | | +| CHOICE Format | | | | | +| >E2SM-NI Action Definition Format 1 | M | | 8.2.1.2.1 | | +| > E2SM-NI Action Definition Format 2 | M | | 8.2.1.2.2 | | + +##### 8.2.1.2.1 E2SM-NI Action Definition Format 1 + +The *E2SM-NI Action Definition* IE Format 1 supports a sequence of RAN Parameters sent as ID/Value pairs. The meaning of the ID/Value pairs is defined in section 7. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-----------------------------|-----------------------|-----------------------| +| Sequence of RAN Parameters | | 0.. <maxofActionParameters> | | | +| >RAN Parameter ID | M | | 8.3.7 | | +| >RAN Parameter Value | M | | 8.3.9 | | + +| Range bound | Explanation | +|-----------------------|-----------------------------------------------| +| maxofActionParameters | Maximum no. of RAN Parameters. Value is <255> | + +##### 8.2.1.2.2 E2SM-NI Action Definition Format 2 + +The *E2SM-NI Action Definition* IE Format 2 supports a POLICY encoded as a list of RAN UE Groups, each with a group identifier, group definition described in terms of a list of RAN parameters with test conditions and a command described in terms of a list of RAN parameters. The meaning of the ID/Value pairs is defined in section 7 and Annex A. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------|----------|-----------------------|-----------------------|----------------------------------------------| +| Sequence of RAN UE Group | | 0..<maxofRANueGroups> | | | +| >RAN UE Group ID | M | | 8.3.14 | | +| >RAN UE Group Definition | M | | 8.3.15 | Defines RAN UE group | +| >RAN Imperative Policy | M | | 8.3.16 | Defines policy to be applied to RAN UE Group | + +| Range bound | Explanation | +|------------------|--------------------------------------------------------------------------------------------| +| maxofRANueGroups | Maximum no. of RAN UE Groups in action definition supported by RAN Function. Value is 255. | + +#### 8.2.1.3 RIC Indication Header IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to a Near-RT RIC node and is required for REPORT and INSERT actions. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE Format | | | | | +| >E2SM-NI Indication Header Format 1 | M | | 8.2.1.3.1 | | + +##### 8.2.1.3.1 E2SM-NI Indication Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------|----------|-------|-----------------------|-----------------------| +| Network Interface Type | M | | 8.3.21 | | +| Network Interface Identifier | M | | 8.3.22 | | +| Network Interface Direction | M | | 8.3.23 | | +| Network Interface Timestamp | O | | 8.3.24 | | + +#### 8.2.1.4 RIC Indication Message IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to a Near-RT RIC node and is required for REPORT and INSERT actions. + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE Format | | | | | +| >E2SM-NI Indication Message Format 1 | M | | 8.2.1.4.1 | | + +##### 8.2.1.4.1 E2SM-NI Indication Message Format 1 + +Content is encoded as per definition of network interface type indicated in the Network Interface Type IE in associated RIC Indication Header IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|-------|-----------------------|-----------------------| +| Network Interface Message | M | | 8.3.29 | | + +#### 8.2.1.5 RIC Call Process ID IE + +This information element is part of the RIC INDICATION message sent by the E2 Node to a Near-RT RIC node and is required for INSERT action. The same information element is used in RIC Control procedure + +Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE Format | | | | | +| >E2SM-NI Call Process ID Format 1 | M | | 8.2.1.5.1 | | +| >E2SM-NI Call Process ID Format 2 | M | | 8.2.1.5.2 | | + +##### 8.2.1.5.1 E2SM-NI Call Process ID Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|-------|-----------------------|-----------------------| +| RIC Call process ID approach 1 | M | | 8.3.11.1 | | + +##### 8.2.1.5.2 E2SM-NI Call Process ID Format 2 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------|----------|-------|-----------------------|-----------------------| +| RIC Call process ID approach 2 | M | | 8.3.11.2 | | + +#### 8.2.1.6 RIC Control Header IE + +This information element is part of the RIC CONTROL message sent by the Near-RT RIC to a E2 Node and is required for RIC Control Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE Format | | | | | +| >E2SM-NI Control Header Format 1 | M | | 8.2.1.6.1 | | + +##### 8.2.1.6.1 E2SM-NI Control Header Format 1 + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------|----------|-------|-----------------------|-----------------------| +| Network Interface Type | M | | 8.3.21 | | +| Network Interface Identifier | M | | 8.3.22 | | +| Network Interface Direction | M | | 8.3.23 | | +| RIC Control Message Priority | O | | 8.3.12 | | + +#### 8.2.1.7 RIC Control Message IE + +This information element is part of the RIC CONTROL message sent by the Near-RT RIC to a E2 Node and is required for RIC Control Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE Format | | | | | +| >E2SM-NI Control Message Format 1 | M | | 8.2.1.7.1 | | + +##### 8.2.1.7.1 E2SM-NI Control Message Format 1 + +Content is encoded as per definition of network interface type indicated in the Network Interface Type IE in associated RIC Control Header IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|-------|-----------------------|-----------------------| +| Network Interface Message | M | | 8.3.29 | | + +#### 8.2.1.8 RIC Control Outcome IE + +This information element is part of the RIC CONTROL ACKNOWLEDGEMENT and RIC CONTROL FAILURE messages and is sent by the E2 Node to the Near-RT RIC and is required for RIC Control Procedure. + +Direction: Near-RT RIC → E2 Node. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE Format | | | | | +| >E2SM-NI Control Outcome Format 1 | M | | 8.2.1.8.1 | | + +##### 8.2.1.8.1 E2SM-NI Control Outcome Format 1 + +The *E2SM-NI Control Outcome* IE Format 1 supports a sequence of RAN Parameters sent as ID/Value pairs. The meaning of the ID/Value pairs is defined in section 7. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|------------------------------|-----------------------|-----------------------| +| Sequence of RAN Parameters | | 0..<br><maxofRAN parameters> | | | +| >RAN Parameter ID | M | | 8.3.7 | | +| >RAN Parameter Value | M | | 8.3.9 | | + +| Range bound | Explanation | +|--------------------|-----------------------------------------------| +| maxofRANparameters | Maximum no. of RAN Parameters. Value is <255> | + +1 + +### 8.2.2 Messages for RIC Global Procedures + +2 + +#### 8.2.2.1 RAN Function Definition IE + +3 + +4 This information element is part of the E2 SETUP REQUEST and RIC SERVICE UPDATE message sent by the RAN +5 to a NEAR-RT RIC node and is used to provide all required information for the Near-RT RIC to determine how a given +6 E2 Node has been configured to support a given RAN Function specific E2SM. + +7 Direction: E2 Node → Near-RT RIC. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------------|----------|--------------------------|-----------------------|--------------------------------------------------| +| RAN Function Name | M | | 8.3.2 | | +| Sequence of Network Interface Types | | 1.. <maxofNltypes> | | | +| >Network Interface Type | M | | 8.3.21 | | +| >Sequence of Event trigger styles | | 0.. <maxofRICstyles> | | | +| >>RIC Event Trigger Style Type | M | | 8.3.3 | ID of Event trigger style | +| >>RIC Event Trigger Style Name | M | | 8.3.4 | Name of Event trigger style | +| >>RIC Event Trigger Format Type | M | | 8.3.5 | Event trigger format used by Event trigger style | +| >Sequence of Report styles | | 0.. <maxofRICstyles> | | | +| >>RIC Report Style Type | M | | 8.3.3 | ID of Report style | +| >>RIC Report Style Name | M | | 8.3.4 | Name of Report style | +| >>RIC Report Action Format Type | M | | 8.3.5 | Action definition format used by Report style | +| >>Sequence of RAN parameters for Action | | 0.. <maxofRANparameters> | | RAN parameters used by Report style | +| >>>RAN Parameter ID | M | | 8.3.7 | | +| >>>RAN Parameter Name | M | | 8.3.10 | | +| >>>RAN Parameter Type | M | | 8.3.6 | | +| >>RIC Indication Header Format Type | M | | 8.3.5 | Indication header format used by Report style | +| >>RIC Indication Message Format Type | M | | 8.3.5 | Indication message format used by Report style | +| >Sequence of Insert styles | | 0.. <maxofRICstyles> | | | +| >>RIC Insert Style Type | M | | 8.3.3 | ID of Insert style | +| >>RIC Insert Style Name | M | | 8.3.4 | Name of Insert style | +| >>RIC Insert Action Format Type | M | | 8.3.5 | Action definition format used by Insert style | +| >>Sequence of RAN parameters for Action | | 0.. <maxofRANparameters> | | RAN parameters used by Insert style | +| >>>RAN Parameter ID | M | | 8.3.7 | | +| >>>RAN Parameter Name | M | | 8.3.10 | | +| >>>RAN Parameter Type | M | | 8.3.6 | | +| >>RIC Indication Header Format Type | M | | 8.3.5 | Indication header format used by Insert style | +| >>RIC Indication Message Format Type | M | | 8.3.5 | Indication message format used by Insert style | +| >>RIC Call Process ID Format Type | M | | 8.3.5 | Call Process ID format used by Insert style | +| >Sequence of Control styles | | 0.. <maxofRICstyles> | | | +| >>RIC Control Style Type | M | | 8.3.3 | ID of Control style | + +| | | | | | +|--------------------------------------------------|---|--------------------------|--------|-----------------------------------------------| +| >>RIC Control Style Name | M | | 8.3.4 | Name of Control style | +| >>RIC Control Header Format Type | M | | 8.3.5 | Control header format used by control style | +| >>RIC Control Message Format Type | M | | 8.3.5 | Control message format used by control style | +| >>RIC Call Process ID Format Type | M | | 8.3.5 | Call Process ID format used by control style | +| >>RIC Control Outcome Format Type | M | | 8.3.5 | Call Process ID format used by control style | +| >>Sequence of RAN parameters for Control Outcome | | 0.. <maxofRANparameters> | | RAN parameters used by Control Outcome style | +| >>>RAN Parameter ID | M | | 8.3.7 | | +| >>>RAN Parameter Name | M | | 8.3.10 | | +| >>>RAN Parameter Type | M | | 8.3.6 | | +| >Sequence of Policy styles | | 0.. <maxofRICstyles> | | | +| >>RIC Policy Style Type | M | | 8.3.3 | | +| >>RIC Policy Style Name | M | | 8.3.4 | | +| >>RIC Policy Action Format Type | M | | 8.3.5 | Action definition format used by Policy style | +| >>Sequence of RAN parameters for Action | | 0.. <maxofRANparameters> | | RAN parameters used by Policy style | +| >>>RAN Parameter ID | M | | 8.3.7 | | +| >>>RAN Parameter Name | M | | 8.3.10 | | +| >>>RAN Parameter Type | M | | 8.3.6 | | + +| Range bound | Explanation | +|--------------------|-------------------------------------------------------------------------------------------------------------| +| maxofNItypes | Maximum no. of Network Interface Types supported by RAN Function <63> | +| maxofRICstyles | Maximum no. of Style of Report, Insert, Control or Policy actions supported by RAN Function. Value is <63>. | +| maxofRANparameters | Maximum no. of RAN Parameters for given style. Value is <65535> | + +## 8.3 Information Element definitions + +### 8.3.1 General + +When specifying information elements which are to be represented by bit strings, if not otherwise specifically stated in the semantics description of the concerned IE or elsewhere, the following principle applies with regards to the ordering of bits: + +- The first bit (leftmost bit) contains the most significant bit (MSB); +- The last bit (rightmost bit) contains the least significant bit (LSB); + +- When importing bit strings from other specifications, the first bit of the bit string contains the first bit of the concerned information. + +### 8.3.2 RAN Function name + +This IE defines the Name of a given *RAN Function Name* IE as a structured data. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------------------------|----------|-------|----------------------------------------|---------------------------------------------------------------------------------------------------------------------| +| RAN Function Short Name | M | | PrintableString(SIZE(1..150,...)) | ORAN-WG3-NI | +| RAN Function Service Model<br>OID | M | | PrintableString(SIZE(1..1000,...)<br>) | Object Identifier of<br>this specific E2SM.<br>Formatted as per<br>OID<br>(1.3.6.1.4.1.53148.1<br>.2.1 for E2SM-NI) | +| RAN Function Description | M | | PrintableString(SIZE(1..150,...)) | "Network Interface" | +| RAN Function Instance | O | | INTEGER | Default 0 assumed<br>if absent | + +### 8.3.3 RIC Style Type + +This IE defines the Identifier of a given *RIC Style Type* IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------|-----------------------| +| RIC Style Type | M | | INTEGER | | + +Note: Assignment of RIC Style Type values is described in section 7 + +### 8.3.4 RIC Style Name + +This IE defines the *RIC Style Name* IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------|----------|-------|-----------------------------------|-----------------------| +| RIC Style Name | M | | PrintableString(SIZE(1..150,...)) | | + +Note: Assignment of RIC Style Name values is described in section 7 + +### 8.3.5 RIC Format Type + +This IE defines the Identifier of a given *RIC Format Type* IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------|----------|-------|-----------------------|-----------------------| +| RIC Format Type | M | | INTEGER | | + +Note: Assignment of RIC Format Type values is described in section 7 and summarized in section 7.8. + +### 8.3.6 RAN Parameter Type + +This IE defines the RAN function specific *RAN Parameter Type* IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------|----------|-------|------------------------------------------------------------------------------------------|-----------------------| +| RAN Parameter Type | M | | ENUMERATED (integer, enumerated, boolean, bit string, octet string, printable string...) | | + +### 8.3.7 RAN Parameter ID + +This IE defines the RAN function specific *RAN parameter ID* IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------|----------|-----------------------|-----------------------|-----------------------| +| RAN Parameter ID | M | 0..maxofRANparameters | INTEGER | | + +| Range bound | Explanation | +|--------------------|----------------------------------------------------| +| maxofRANparameters | Maximum no. of RAN Parameter ID. Value is < 65535> | + +### 8.3.8 RAN Parameter Test Condition + +This IE defines the RAN Function specific *RAN Parameter Test Condition* IE to be used to compare the particular value of a given parameter with the target value. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------------|----------|-------|-------------------------------------------------------------------|-----------------------| +| RAN Parameter Test Condition | M | | ENUMERATED (equal, greaterthan, lessthan, contains, present, ...) | | + +For all cases the test condition is Value (*RAN Parameter ID*) (*RAN Parameter Test Condition*) (*RAN Parameter Value*). + +For example: + +- If RAN Parameter Test Condition = “equal” then test condition is: +Value (RAN Parameter ID) = (RAN Parameter Value) +- If RAN Parameter Test Condition = “greaterthan” then test condition is: +Value (RAN Parameter ID) > (RAN Parameter Value) + +### 8.3.9 RAN Parameter Value + +This IE defines the *RAN Parameter Value* IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE RAN Parameter Value | M | | | | +| >INTEGER | | | INTEGER | | +| >ENUMERATED | | | INTEGER | | +| >BOOLEAN | | | BOOLEAN | | +| >BIT STRING | | | BIT STRING | | +| >OCTET STRING | | | OCTET STRING | | +| >PRINTABLE STRING | | | PrintableString | | + +### 8.3.10 RAN Parameter Name + +This IE defines the *RAN Parameter Name* IE of a given RAN Parameter ID. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------|----------|-------|-----------------------------------|-----------------------| +| RAN Parameter Name | M | | PrintableString(SIZE(1..150,...)) | | + +### 8.3.11 RAN Call process ID + +#### 8.3.11.1 RAN Call process ID approach 1 + +This IE defines the required Call process ID approach 1. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------|-----------------------| +| Call process ID number | | | INTEGER | | + +#### 8.3.11.1 RAN Call process ID approach 2 + +This IE defines the required Call process ID approach 2 IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------------------|-----------------------| +| Call process ID string | | | PrintableString(SIZE(1..150,...)) | | + +### 8.3.12 RIC Control Message Priority + +This IE defines the *RIC Control Message Priority* IE + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|------------------------|----------|-------|-----------------------|-----------------------| +| ControlMessagePriority | M | | INTEGER | | + +### 8.3.13 reserved + +### 8.3.14 RAN UE Group ID + +This IE defines the generic *RAN UE Group ID* IE + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-----------------|----------|-------|-----------------------|-----------------------| +| RAN UE Group ID | M | | INTEGER | | + +| Range bound | Explanation | +|------------------|----------------------------------------------| +| maxofRANueGroups | Maximum no. of RAN UE Groups. Value is <255> | + +### 8.3.15 RAN UE Group Definition + +This IE defines the generic *RAN UE Group Definition* IE + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------|----------|-------------------------|-----------------------|-----------------------| +| Sequence of RAN Parameters | | 0..<maxofRANparameters> | | Defines RAN UE group | +| >RAN Parameter ID | M | | 8.3.7 | | +| >RAN Parameter Test Condition | M | | 8.3.8 | | +| >RAN Parameter Value | M | | 8.3.9 | | + +| Range bound | Explanation | +|--------------------|-------------------------------------------------| +| maxofRANparameters | Maximum no. of RAN Parameter ID. Value is <255> | + +### 8.3.16 RAN Imperative Policy + +This IE defines the generic *RAN Imperative Policy* IE + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------|----------|-------------------------|-----------------------|-----------------------| +| Sequence of RAN Parameters | | 0..<maxofRANparameters> | | Defines RAN UE group | +| >RAN Parameter ID | M | | 8.3.7 | | +| >RAN Parameter Value | M | | 8.3.9 | | + +| Range bound | Explanation | +|--------------------|----------------------------------------------------------------------------------------------------| +| maxofRANparameters | Maximum no. of RAN Parameter types in action definition supported by RAN Function. Value is <255>. | + +### 8.3.17 reserved + +### 8.3.18 reserved + +### 8.3.19 reserved + +### 8.3.20 reserved + +### 8.3.21 Network Interface Type + +This IE defines the Network Interface Type as a list referring to a standardized Network Interface Type. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|------------------------------------------|-----------------------| +| NetworkInterfaceType | M | | ENUMERATED (S1, X2, NG, Xn, F1, E1, ...) | | + +Where: + +- S1 means S1 interface [10] +- X2 means X2 interface [11] +- NG means NG (N2) interface [12] +- Xn means Xn interface [13] +- F1 means F1 interface [14] +- E1 means E1 interface [15] + +### 8.3.22 Network Interface Identifier + +This IE defines the Network Interface Identifier in terms of global identifier of the network node terminating a specific network interface. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|--------------------------------------|----------|-------|------------------------------------------------------|--------------------------------| +| CHOICE<br>NetworkInterfaceIdentifier | M | | | | +| >Global eNB ID | | | As defined in spec 3GPP 36.413 [10] section 9.2.1.37 | For S1, X2 | +| >Global en-gNB ID | | | As defined in spec 3GPP 36.423 [11] section 9.2.112 | For X2 | +| >Global ng-RAN ID | | | As defined in spec 3GPP 38.413 [12] section 9.3.1.5 | For NG, Xn, F1, E1 | +| >Global gNB-DU ID | | | | For F1 | +| >> Global ng-RAN ID | M | | As defined in spec 3GPP 38.413 [12] section 9.3.1.5 | Used as prefix to gNB-DU ID | +| >>gNB-DU ID | M | | As defined in spec 3GPP 38.473 [14] section 9.3.1.9 | For F1 | +| >Global gNB-CU-UP ID | | | | For E1 | +| >> Global ng-RAN ID | M | | As defined in spec 3GPP 38.413 [12] section 9.3.1.5 | Used as prefix to gNB-CU-UP ID | +| >>gNB-CU-UP ID | M | | As defined in spec 3GPP 38.463 [15] section 9.3.1.15 | For E1 | + +Notes: + +- O-CU and O-CU-CP nodes terminating F1 and O-CU-CP nodes terminating E1 interfaces are identified by the associated Global RAN Node ID +- O-DU nodes terminating F1 and O-CU-UP terminating E1 interfaces are identified by the local gNB-DU-ID or gNB-CU-UP ID with a prefix Global RAN Node ID identifying logical gNB + +### 8.3.23 Network Interface Direction + +This IE defines the *Network Interface Direction* IE. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|-------|--------------------------------------------|-----------------------| +| NetworkInterfaceDirection | M | | ENUMERATED (incoming, outgoing, both, ...) | | + +### 8.3.24 Network Interface Timestamp + +This IE defines the NetworkInterfaceTimestamp. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|-------|------------------------|------------------------------------------------------------------------------------------------------------------------------------------| +| NetworkInterfaceTimestamp | M | | OCTET STRING (SIZE(8)) | UTC time encoded as the 64-bit timestamp format as defined in section 6 of IETF RFC 5905 [35] containing both seconds and fraction parts | + +### 8.3.25 Network Interface Message Type + +This IE defines the NetworkInterfaceMessageType in terms of Message Type structure data of the specific network interface. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|-------------------------------------------|----------|-------|-----------------------------------------------------|-----------------------| +| CHOICE<br>NetworkInterfaceMessageTy<br>pe | M | | | | +| >S1 message type | | | As defined in spec 3GPP 36.413 [10] section 9.3.1.1 | For S1 | +| >X2 message type | | | As defined in spec 3GPP 36.423 [11] section 9.2.13 | For X2 | +| >NG message type | | | As defined in spec 3GPP 38.413 [12] section 9.3.1.1 | For NG | +| >Xn message type | | | As defined in spec 3GPP 38.423 [12] section 9.2.3.1 | For Xn | +| >F1 message type | | | As defined in spec 3GPP 38.473 [12] section 9.3.1.1 | For F1 | +| >E1 message type | | | As defined in spec 3GPP 38.463 [12] section 9.3.1.1 | For E1 | + +### 8.3.26 Message Protocol IE Identifier + +This IE defines the MessageProtocolIE-ID + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------|----------|-------|-----------------------|-----------------------| +| MessageProtocolIE-ID | M | | INTEGER | | + +Notes: + +- Refer to the specific target interface specification for the assignment of network interface specific Message Protocol IE Identifier +- Common definition of type "INTEGER" has been observed to be adopted by all 3GPP interfaces and so assumed here. + +### 8.3.27 Message Protocol IE Test Condition + +This IE defines the network interface message protocol IE specific test condition to be used to compare the particular value of a given parameter with the target value. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------------|----------|-------|-------------------------------------------------------------------|-----------------------| +| MessageProtocolIE-TestCondition | M | | ENUMERATED (equal, greaterthan, lessthan, contains, present, ...) | | + +For all cases the test condition is Value (*Message Protocol IE ID*) (*Message Protocol IE Test Condition*) (*Message Protocol IE Test Value*). + +For example: + +- If Message Protocol IE Test Condition = “equal” then test condition is: +Value (*Message Protocol IE ID*) = (*Message Protocol IE Test Value*) +- If Message Protocol IE Test Condition = “greaterthan” then test condition is: +Value (*Message Protocol IE ID*) > (*Message Protocol IE Test Value*) + +### 8.3.28 Message Protocol IE Value + +This IE defines the target value type for a particular Message Protocol IE element. + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|----------------------------------|----------|-------|-----------------------|-----------------------| +| CHOICE Message Protocol IE Value | M | | | | +| >INTEGER | | | INTEGER | | +| >ENUMERATED | | | INTEGER | | +| >BOOLEAN | | | BOOLEAN | | +| >BIT STRING | | | BIT STRING | | +| >OCTET STRING | | | OCTET STRING | | +| >PRINTABLE STRING | | | PrintableString | | + +### 8.3.29 Network Interface Message + +This IE defines the *Network Interface Message Container* IE + +| IE/Group Name | Presence | Range | IE type and reference | Semantics description | +|---------------------------|----------|-------|-----------------------|-----------------------| +| Network Interface Message | M | | OCTET STRING | | + +Note: The actual contents of the message is defined in the network interface specification. + +## 8.4 Information Element Abstract Syntax (with ASN.1) + +### 8.4.1 General + +E2SM ASN.1 definition conforms to ITU-T Rec. X.680 [5] and ITU-T Rec. X.681 [6]. + +Sub clause 8.4.2 presents the Abstract Syntax of the E2SM information elements to be carried within the E2AP [3] protocol messages with ASN.1. In case there is contradiction between the ASN.1 definition in this sub clause and the tabular format in sub clause 8.2 and 8.3, the ASN.1 shall take precedence, except for the definition of conditions for the presence of conditional elements, in which the tabular format shall take precedence. + +If an E2SM information element carried as an OCTET STRING in an E2AP [3] message that is not constructed as defined above is received, this shall be considered as Abstract Syntax Error, and the message shall be handled as defined for Abstract Syntax Error in clause 9. + +### 8.4.2 Information Element definitions + +``` +-- ASN1START +-- ***** +-- E2SM-NI +-- Information Element Definitions +-- ***** + +E2SM-NI-IEs { +iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 53148 e2(1) version1 +(1) e2sm(2) e2sm-NI-IEs (1)} + +DEFINITIONS AUTOMATIC TAGS ::= + +BEGIN + +-- ***** +-- IEs +-- ***** + +-- ***** +-- copied from X2AP IEs v15.4.0 +-- note: ie-Extensions removed +-- Note: to avoid duplicate names with XnAP, GNB-ID renamed ENGNB-ID, GlobalGNB-ID renamed +GlobalenGNB-ID +-- ***** + +GlobalenB-ID ::= SEQUENCE { + pLMN-Identity PLMN-Identity, + eNB-ID ENB-ID, + ... +} + +ENB-ID ::= CHOICE { + macro-eNB-ID BIT STRING (SIZE (20)), + home-eNB-ID BIT STRING (SIZE (28)), + ... , + short-Macro-eNB-ID BIT STRING (SIZE(18)), + long-Macro-eNB-ID BIT STRING (SIZE(21)) +} + +GlobalenGNB-ID ::= SEQUENCE { + pLMN-Identity PLMN-Identity, + gNB-ID ENGNB-ID, + ... +} + +ENGNB-ID ::= CHOICE { + gNB-ID BIT STRING (SIZE (22..32)), + ... +} + +PLMN-Identity ::= OCTET STRING (SIZE(3)) + +-- ***** +``` + +``` + +-- copied from 38.463 v15.5.0 E1AP IEs + +GNB-CU-UP-ID::= INTEGER (0..68719476735) + + +-- copied from 38.473 v15.4.1 F1AP IEs + +GNB-DU-ID::= INTEGER (0..68719476735) + + +-- copied from 38.423 v15.5.0 XnAP IEs +-- note: ie-Extensions removed +-- note: + +GlobalgNB-ID ::= SEQUENCE { + plmn-id PLMN-Identity, + gnb-id GNB-ID-Choice, + ... +} +GNB-ID-Choice ::= CHOICE { + gnb-ID BIT STRING (SIZE(22..32)), + ... +} + +GlobalngNB-ID ::= SEQUENCE { + plmn-id PLMN-Identity, + enb-id ENB-ID-Choice, + ... +} + +ENB-ID-Choice ::= CHOICE { + enb-ID-macro BIT STRING (SIZE(20)), + enb-ID-shortmacro BIT STRING (SIZE(18)), + enb-ID-longmacro BIT STRING (SIZE(21)), + ... +} + +GlobalNG-RANNode-ID ::= CHOICE { + gNB GlobalgNB-ID, + ng-eNB GlobalngNB-ID, + ... +} + + + +-- +-- copied from X2AP common data types v15.4.0 +-- + + +maxProtocolIEs INTEGER ::= 65535 + +Criticality ::= ENUMERATED { reject, ignore, notify } + +Presence ::= ENUMERATED { optional, conditional, mandatory } + +ProcedureCode ::= INTEGER (0..255) + +ProtocolIE-ID ::= INTEGER (0..maxProtocolIEs) + + + +-- +-- Lists +-- + + +maxofInterfaceProtocolTests INTEGER ::= 15 +maxofRANueGroups INTEGER ::= 255 +maxofActionParameters INTEGER ::= 255 +maxofRANparameters INTEGER ::= 65535 +maxofNTypes INTEGER ::= 63 +maxofRICstyles INTEGER ::= 63 + +``` + +``` + +1 -- ***** +2 -- E2SM-NI Service model IEs +3 -- ***** +4 +5 ----- +6 -- Event Trigger Definition OCTET STRING contents +7 ----- +8 +9 -- E2SM-NI-EventTriggerDefinition IE +10 E2SM-NI-EventTriggerDefinition ::= CHOICE{ +11 eventDefinition-Format1 E2SM-NI-EventTriggerDefinition-Format1, +12 ... +13 } +14 +15 -- E2SM-NI-EventTriggerDefinition IE is used for Event Trigger Definition Format 1 +16 E2SM-NI-EventTriggerDefinition-Format1 ::= SEQUENCE{ +17 interface-type NI-Type, +18 interface-ID NI-Identifier, +19 interfaceDirection NI-Direction, +20 interfaceMessageType NI-MessageType, +21 interfaceProtocolIE-List SEQUENCE (SIZE(1..maxofInterfaceProtocolTests)) OF NI-ProtocolIE- +22 Item OPTIONAL, +23 ... +24 } +25 +26 ----- +27 -- Action Definition OCTET STRING contents +28 ----- +29 -- E2SM-NI-ActionDefinition IE +30 E2SM-NI-ActionDefinition ::= SEQUENCE{ +31 ric-Style-Type RIC-Style-Type, +32 action-Definition-Format E2SM-NI-ActionDefinitionFormat, +33 ... +34 } +35 +36 E2SM-NI-ActionDefinitionFormat ::= CHOICE{ +37 actionDefinition-Format1 E2SM-NI-ActionDefinition-Format1, +38 actionDefinition-Format2 E2SM-NI-ActionDefinition-Format2, +39 ... +40 } +41 +42 -- E2SM-NI-ActionDefinition IE is used for Action Format 1 +43 E2SM-NI-ActionDefinition-Format1 ::= SEQUENCE{ +44 actionParameter-List SEQUENCE (SIZE(1..maxofActionParameters)) OF RANparameter-Item +45 OPTIONAL, +46 ... +47 } +48 +49 -- E2SM-NI-ActionDefinition IE is used for Action Format 2 +50 E2SM-NI-ActionDefinition-Format2 ::= SEQUENCE{ +51 ranUEgroup-List SEQUENCE (SIZE(1..maxofRANueGroups)) OF RANueGroup-Item OPTIONAL, +52 ... +53 } +54 +55 ----- +56 -- Indication Header OCTET STRING contents +57 ----- +58 +59 -- E2SM-NI-IndicationHeader IE +60 E2SM-NI-IndicationHeader ::= CHOICE{ +61 indicationHeader-Format1 E2SM-NI-IndicationHeader-Format1, +62 ... +63 } +64 +65 -- E2SM-NI-IndicationHeader Format 1 +66 E2SM-NI-IndicationHeader-Format1 ::= SEQUENCE{ +67 interface-type NI-Type, +68 interface-ID NI-Identifier, +69 interfaceDirection NI-Direction, +70 timestamp NI-TimeStamp OPTIONAL, +71 ... +72 } +73 +74 ----- +75 -- Indication Message OCTET STRING contents +76 ----- +77 + +``` + +``` + +1 +2 -- E2SM-NI-IndicationMessage IE +3 E2SM-NI-IndicationMessage ::= CHOICE{ +4 indicationMessage-Format1 E2SM-NI-IndicationMessage-Format1, +5 ... +6 } +7 +8 -- E2SM-NI-IndicationMessage IE +9 E2SM-NI-IndicationMessage-Format1 ::= SEQUENCE{ +10 interfaceMessage NI-Message, +11 ... +12 } +13 +14 ----- +15 -- Call Process ID +16 ----- +17 +18 E2SM-NI-CallProcessID ::= CHOICE{ +19 callProcessID-Format1 E2SM-NI-CallProcessID-Format1, +20 callProcessID-Format2 E2SM-NI-CallProcessID-Format2, +21 ... +22 } +23 -- E2SM-NI-callProcessID IE Format 1 +24 +25 E2SM-NI-CallProcessID-Format1 ::= SEQUENCE{ +26 callProcess-ID RANcallProcess-ID-number, +27 ... +28 } +29 +30 E2SM-NI-CallProcessID-Format2 ::= SEQUENCE{ +31 callProcess-ID RANcallProcess-ID-string, +32 ... +33 } +34 +35 ----- +36 -- Control Header OCTET STRING contents +37 ----- +38 +39 -- E2SM-NI-ControlHeader IE +40 E2SM-NI-ControlHeader ::= CHOICE{ +41 controlHeader-Format1 E2SM-NI-ControlHeader-Format1, +42 ... +43 } +44 -- E2SM-NI-ControlHeader Format 1 +45 E2SM-NI-ControlHeader-Format1 ::= SEQUENCE{ +46 interface-type NI-Type, +47 interface-ID NI-Identifier, +48 interface-Direction NI-Direction, +49 ric-Control-Message-Priority RIC-Control-Message-Priority OPTIONAL, +50 ... +51 } +52 +53 ----- +54 -- Control Message OCTET STRING contents +55 ----- +56 +57 -- E2SM-NI-ControlHeader IE +58 E2SM-NI-ControlMessage ::= CHOICE{ +59 controlMessage-Format1 E2SM-NI-ControlMessage-Format1, +60 ... +61 } +62 +63 -- E2SM-NI-ControlMessage Format 1 +64 E2SM-NI-ControlMessage-Format1 ::= SEQUENCE{ +65 interfaceMessage NI-Message, +66 ... +67 } +68 +69 ----- +70 -- Control Outcome OCTET STRING contents +71 ----- +72 +73 -- E2SM-NI-ControlOutcome IE +74 E2SM-NI-ControlOutcome ::= CHOICE{ +75 controlOutcome-Format1 E2SM-NI-ControlOutcome-Format1, +76 ... +77 + +``` + +``` + +} + +-- E2SM-NI-ControlOutcome Format 1 +E2SM-NI-ControlOutcome-Format1 ::= SEQUENCE{ + outcomeElement-List SEQUENCE (SIZE(1..maxofRANparameters)) OF RANparameter-Item OPTIONAL, + ... +} + + +-- RAN Function Description OCTET STRING contents + + +-- E2SM-NI-RANfunction-Description +E2SM-NI-RANfunction-Description ::= SEQUENCE{ + ranFunction-Name RANfunction-Name, + ni-Type-List SEQUENCE (SIZE(1..maxofNItypes)) OF E2SM-NI-RANfunction-Item OPTIONAL, + ... +} + +E2SM-NI-RANfunction-Item ::= SEQUENCE{ + interface-type NI-Type, + ric-EventTriggerStyle-List SEQUENCE (SIZE(1..maxofRICstyles)) OF RIC-EventTriggerStyle-List OPTIONAL, + ric-ReportStyle-List SEQUENCE (SIZE(1..maxofRICstyles)) OF RIC-ReportStyle-List OPTIONAL, + ric-InsertStyle-List SEQUENCE (SIZE(1..maxofRICstyles)) OF RIC-InsertStyle-List OPTIONAL, + ric-ControlStyle-List SEQUENCE (SIZE(1..maxofRICstyles)) OF RIC-ControlStyle-List OPTIONAL, + ric-PolicyStyle-List SEQUENCE (SIZE(1..maxofRICstyles)) OF RIC-PolicyStyle-List OPTIONAL, + ... +} + + +-- commmon IEs + + +-- A +-- B +-- C +-- D +-- E +-- F +-- G +Global-eNB-ID ::= GlobalENB-ID +Global-en-gNB-ID ::= GlobalenGNB-ID +Global-gNB-DU-ID ::= SEQUENCE{ + global-ng-RAN-ID Global-ng-RAN-ID, + gNB-DU-ID GNB-DU-ID +} + +Global-gNB-CU-UP-ID ::= SEQUENCE{ + global-ng-RAN-ID Global-ng-RAN-ID, + gNB-CU-UP-ID GNB-CU-UP-ID +} + +Global-ng-RAN-ID ::= GlobalNG-RANNode-ID +-- H +-- I +-- J +-- K +-- L +-- M +-- N +NI-Direction ::= ENUMERATED{ + incoming, + outgoing, + both, + ... +} + + + +NI-Identifier ::= CHOICE{ + global-eNB-ID Global-eNB-ID, + global-en-gNB-ID Global-en-gNB-ID, + global-ng-RAN-ID Global-ng-RAN-ID, + global-gNB-DU-ID Global-gNB-DU-ID, + global-gNB-CU-UP-ID Global-gNB-CU-UP-ID, + +``` + +``` + +1 +2 ... +3 } +4 +5 +6 NI-Message ::= OCTET STRING +7 +8 NI-MessageType ::= CHOICE{ +9 s1MessageType NI-MessageTypeS1, +10 x2MessageType NI-MessageTypeX2, +11 ngMessageType NI-MessageTypeNG, +12 xnMessageType NI-MessageTypeXn, +13 flMessageType NI-MessageTypeFl, +14 elMessageType NI-MessageTypeEl, +15 ... +16 } +17 +18 NI-MessageTypeS1 ::= NI-MessageTypeApproach1 +19 NI-MessageTypeX2 ::= NI-MessageTypeApproach1 +20 NI-MessageTypeNG ::= NI-MessageTypeApproach1 +21 NI-MessageTypeXn ::= NI-MessageTypeApproach1 +22 NI-MessageTypeFl ::= NI-MessageTypeApproach1 +23 NI-MessageTypeEl ::= NI-MessageTypeApproach1 +24 +25 NI-MessageTypeApproach1 ::= SEQUENCE { +26 procedureCode ProcedureCode, +27 typeOfMessage TypeOfMessage, +28 ... +29 } +30 +31 TypeOfMessage ::= ENUMERATED { nothing, initiating-message, successful-outcome, unsuccessful- +32 outcome } +33 +34 +35 NI-ProtocolIE-Item ::= SEQUENCE{ +36 interfaceProtocolIE-ID NI-ProtocolIE-ID, +37 interfaceProtocolIE-Test NI-ProtocolIE-Test, +38 interfaceProtocolIE-Value NI-ProtocolIE-Value, +39 ... +40 } +41 +42 NI-ProtocolIE-ID ::= ProtocolIE-ID +43 +44 NI-ProtocolIE-Test ::= ENUMERATED{ +45 equal, +46 greaterthan, +47 lessthan, +48 contains, +49 present, +50 ... +51 } +52 +53 NI-ProtocolIE-Value ::= CHOICE{ +54 valueInt INTEGER, +55 valueEnum INTEGER, +56 valueBool BOOLEAN, +57 valueBitS BIT STRING, +58 valueOctS OCTET STRING, +59 valuePrts PrintableString, +60 ... +61 } +62 +63 NI-TimeStamp ::= OCTET STRING (SIZE(8)) +64 +65 NI-Type ::= ENUMERATED{ +66 s1, +67 x2, +68 ng, +69 xn, +70 fl, +71 el, +72 ... +73 } +74 +75 -- O +76 -- P +77 -- Q + +``` + +``` + +-- R + +RANcallProcess-ID-number ::= INTEGER + +RANcallProcess-ID-string ::= PrintableString(SIZE(1..150,...)) + +RANfunction-Name ::= SEQUENCE{ + ranFunction-ShortName PrintableString(SIZE(1..150,...)), + ranFunction-E2SM-OID PrintableString(SIZE(1..1000,...)), + ranFunction-Description PrintableString(SIZE(1..150,...)), + ranFunction-Instance INTEGER OPTIONAL, + ... +} + + +RANimperativePolicy ::= SEQUENCE{ + ranImperativePolicy-List SEQUENCE (SIZE(1..maxofRANparameters)) OF RANparameter-Item OPTIONAL, + ... +} + +RANparameter-Item ::= SEQUENCE { + ranParameter-ID RANparameter-ID, + ranParameter-Value RANparameter-Value, + ... +} + +RANparameterDef-Item ::= SEQUENCE { + ranParameter-ID RANparameter-ID, + ranParameter-Name RANparameter-Name, + ranParameter-Type RANparameter-Type, + ... +} + +RANparameter-ID ::= INTEGER (0..maxofRANparameters) + +RANparameter-Name ::= PrintableString(SIZE(1..150,...)) + +RANparameter-Test-Condition ::= ENUMERATED{ + equal, + greaterthan, + lessthan, + contains, + present, + ... +} + +RANparameter-Type ::= ENUMERATED{ + integer, + enumerated, + boolean, + bit-string, + octet-string, + printable-string, + ... +} + +RANparameter-Value ::= CHOICE{ + valueInt INTEGER, + valueEnum INTEGER, + valueBool BOOLEAN, + valueBitS BIT STRING, + valueOctS OCTET STRING, + valuePrtS PrintableString, + ... +} + + +RANueGroupID ::= INTEGER (0..maxofRANueGroups) + +RANueGroup-Item ::= SEQUENCE { + ranUEgroupID RANueGroupID, + ranUEgroupDefinition RANueGroupDefinition, + ranPolicy RANimperativePolicy, + ... +} + +``` + +``` + +1 +2 +3 RANueGroupDefinition ::= SEQUENCE{ +4 ranUEgroupDef-List SEQUENCE (SIZE(1..maxofRANparameters)) OF RANueGroupDef-Item OPTIONAL, +5 ... +6 } +7 +8 +9 RANueGroupDef-Item ::= SEQUENCE{ +10 ranParameter-ID RANparameter-ID, +11 ranParameter-Test RANparameter-Test-Condition, +12 ranParameter-Value RANparameter-Value, +13 ... +14 } +15 +16 RIC-Control-Message-Priority ::= INTEGER +17 +18 +19 RIC-ControlStyle-List ::= SEQUENCE{ +20 ric-ControlStyle-Type RIC-Style-Type, +21 ric-ControlStyle-Name RIC-Style-Name, +22 ric-ControlFormat-Type RIC-Format-Type, +23 ric-ControlHeaderFormat-Type RIC-Format-Type, +24 ric-ControlMessageFormat-Type RIC-Format-Type, +25 ric-CallProcessIDFormat-Type RIC-Format-Type, +26 ric-ControlOutcomeFormat-Type RIC-Format-Type, +27 ric-ControlOutcomeRanParaDef-List SEQUENCE (SIZE(1..maxofRANparameters)) OF RANparameterDef- +28 Item, +29 ... +30 } +31 +32 RIC-EventTriggerStyle-List ::= SEQUENCE{ +33 ric-EventTriggerStyle-Type RIC-Style-Type, +34 ric-EventTriggerStyle-Name RIC-Style-Name, +35 ric-EventTriggerFormat-Type RIC-Format-Type, +36 ... +37 } +38 RIC-InsertStyle-List ::= SEQUENCE{ +39 ric-InsertStyle-Type RIC-Style-Type, +40 ric-InsertStyle-Name RIC-Style-Name, +41 ric-InsertActionFormat-Type RIC-Format-Type, +42 ric-InsertRanParameterDef-List SEQUENCE (SIZE(1..maxofRANparameters)) OF RANparameterDef- +43 Item, +44 ric-IndicationHeaderFormat-Type RIC-Format-Type, +45 ric-IndicationMessageFormat-Type RIC-Format-Type, +46 ric-CallProcessIDFormat-Type RIC-Format-Type, +47 ... +48 } +49 RIC-PolicyStyle-List ::= SEQUENCE{ +50 ric-PolicyStyle-Type RIC-Style-Type, +51 ric-PolicyStyle-Name RIC-Style-Name, +52 ric-PolicyActionFormat-Type RIC-Format-Type, +53 ric-PolicyRanParameterDef-List SEQUENCE (SIZE(1..maxofRANparameters)) OF RANparameterDef- +54 Item, +55 ... +56 } +57 +58 RIC-ReportStyle-List ::= SEQUENCE{ +59 ric-ReportStyle-Type RIC-Style-Type, +60 ric-ReportStyle-Name RIC-Style-Name, +61 ric-ReportActionFormat-Type RIC-Format-Type, +62 ric-ReportRanParameterDef-List SEQUENCE (SIZE(1..maxofRANparameters)) OF RANparameterDef- +63 Item, +64 ric-IndicationHeaderFormat-Type RIC-Format-Type, +65 ric-IndicationMessageFormat-Type RIC-Format-Type, +66 ... +67 } +68 +69 RIC-Format-Type ::= INTEGER +70 +71 RIC-Style-Type ::= INTEGER +72 +73 RIC-Style-Name ::= PrintableString(SIZE(1..150,...)) +74 +75 +76 -- S +77 -- T + +``` + +``` + +-- U +-- V +-- W +-- X +-- Y +-- Z + +END +-- ASN1STOP + +``` + +## 8.5 Message transfer syntax + +E2SM shall use the ASN.1 Basic Packed Encoding Rules (BASIC-PER) Aligned Variant as transfer syntax, as specified in ITU-T Rec. X.691 [7]. + +# --- 9 Handling of Unknown, Unforeseen and Erroneous Protocol Data + +Section 10 of TS 36.413 [10] is applicable for the purposes of the present document. + +# --- Annex A: Further information on RAN Function Network Interface + +## A.1 Background information + +The RAN function “Network Interface” is used to provide RIC Service expose of the network interface logical function of the E2 Node. + +It is assumed that the network interfaces are terminated on one of more logical functions with the E2 Node. For each logical function the E2 Node shall use the RAN Function Description to declare the list of supported Network Interfaces and the corresponding set of supported RIC Services (**REPORT**, **INSERT**, **CONTROL** and **POLICY**) and for each supported RIC Service the list of supported Styles. + +Each Network Interface is uniquely identified by: + +- Network Interface Type defined by reference to the name of the interface specification (S1, F1, etc.) +- Network Interface Identifier defined by the Global identifier of the network node terminating the network interface + +Furthermore, it is assumed that a given network interface is bidirectional and so has an incoming direction terminated by the E2 Node and an outgoing direction originated by the E2 Node. + +Messages on the network interface are assumed to be encoded in terms of Message Types and each message is assumed to contain one or more Protocol Information Elements (IE) each of which may be identified by the unique Protocol IE Identifier as defined in the corresponding network interface specification. + +Event triggers, Indication and Control procedure message contents and Policy Action Definitions are encoded in terms of the corresponding network interface specification. + +## A.2 X2 Network Interface + +The RAN function “Network Interface” on an E2 Node of type eNB, gNB, gNB-CU and gNB-CU-CP may be used to expose the X2AP (X2c) interface. + +**Editor’s note:** + +List here the specific use cases with corresponding messages and actions that may be exposed for the X2 interface. + +### A.2.1 Message Admission policy handling + +| Use Case | RIC Service | Semantics description | +|-------------------------|---------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| EN-DC Admission Control | E2 POLICY Style 1 on E2 Node of type en-gNB | <p>Event Trigger Definition type 1 = Incoming X2 SgNB Addition Request from eNB</p> <p>RAN UE Group Definition = AND combination of sequence of RAN Parameter tests</p> <p>RAN Imperative Policy = Sequence of RAN parameters used to enhance RAN admission algorithm</p> <p>Negative outcome results in EN-DC SgNB Addition Rejection message sent to eNB and incoming message dropped.</p> | +| | | | + +# Annex ZZZ : O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated + +that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of O-RAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance's sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. + +Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or third party beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full force and effect. \ No newline at end of file diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/156eb7360e6eeb4a3d210dfecb6833c8_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/156eb7360e6eeb4a3d210dfecb6833c8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d88892262ec23bd8f0e95252cbd07e24d1b4066e --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/156eb7360e6eeb4a3d210dfecb6833c8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e7ed1845eeff42b4799cdb075ac08bb0ea2d503e2aad2d08f9326e776f5be8dc +size 63989 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/21d74dce0861e0a807f4f544a0368035_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/21d74dce0861e0a807f4f544a0368035_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..03b80b52e1d0ca48af373ffa0d7df91440a93978 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/21d74dce0861e0a807f4f544a0368035_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:12287238657016e09d152ff511d78190afec2bc0a2f7452f14eda2ef74317d5f +size 27998 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/22818ecb774a3f379eab54476842b2d1_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/22818ecb774a3f379eab54476842b2d1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3709ea58435dd5fe155aeacfe637078beab1dd07 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/22818ecb774a3f379eab54476842b2d1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:052efbece0e2aee6f7463c72affad8aa60516b07ced87659d493befd643e2782 +size 43850 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/26ad6db84883dd27f2cc81bf017fb837_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/26ad6db84883dd27f2cc81bf017fb837_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1a40319dcdd57ce9c46e9da28f9e507c264e3076 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/26ad6db84883dd27f2cc81bf017fb837_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ad3d3219f59f17fbda59874f248b9d256a22b33789a857dc7fdb7da46cc77ec8 +size 39382 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/2dd4d8b8c90bd4995ac92296ce44c708_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/2dd4d8b8c90bd4995ac92296ce44c708_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2570e874fc3c74d6c0ea3ecdcfc68c187e723369 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/2dd4d8b8c90bd4995ac92296ce44c708_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4574e493d7351d4dd866b13bd5c5e4e51990d538c9445c744ac5d462b919eb16 +size 4506 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/2f7ead5d311cae9d9fbd7c1404235a37_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/2f7ead5d311cae9d9fbd7c1404235a37_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b2df7aebb9d6e66d5bd42abea3fcf8b4dbe4ddfd --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/2f7ead5d311cae9d9fbd7c1404235a37_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:615d37deebe19c2c013378bb6b59f380a231116ffd299283fb73ee1cbbeb5dcb +size 4578 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/38cc60bab8b7f31609cf59986ab5ec8d_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/38cc60bab8b7f31609cf59986ab5ec8d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a1e97979958716c30b32df7986bfd7adc7ceeab7 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/38cc60bab8b7f31609cf59986ab5ec8d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:034789f2dda91e0518655eaa320c8bc5f4a60cf59d82fe6bd07a02b42a322f47 +size 80704 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/435cccc6bd742b3a885c4ec296a3fe69_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/435cccc6bd742b3a885c4ec296a3fe69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9e11bbc3f136734df1e523a217492b1bf1b80cef --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/435cccc6bd742b3a885c4ec296a3fe69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c61f39b64ee26c26d281e8e7b4fbd573faf1745ea1d368aa352cee59bc1b6082 +size 36747 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/4602bf6139e5162e21a094adbd9a6376_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/4602bf6139e5162e21a094adbd9a6376_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ec9549c5db6ef2520aad06980a3ae456a3325770 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/4602bf6139e5162e21a094adbd9a6376_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:df4df2cf763ec06e94b5889a4096a22408bc8ddc7e740f523ca85dabdffa39c3 +size 49460 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/4a108205d3a562dde10e047b6cc3f6f7_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/4a108205d3a562dde10e047b6cc3f6f7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d78c9361c0003a321cbffd6f6c7c20e6940727a1 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/4a108205d3a562dde10e047b6cc3f6f7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:24bdce4b416ee968187ed06e8708da53c8543c3f62470ac5ef870dc72c4a3d51 +size 4505 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/4aa4c948463b75633d5b0066df067041_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/4aa4c948463b75633d5b0066df067041_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..88728cf535404f78fa30cd9380a47facc60f60bc --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/4aa4c948463b75633d5b0066df067041_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9b6fbe48bf47dc01a92185ef3682d510645eaf535916939c75de7a31950aa52c +size 61022 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/55c74c4cfffc24d29a81d9247ee037c5_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/55c74c4cfffc24d29a81d9247ee037c5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c1a21fc9c478bed144910f743cbf286cd38f4b9d --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/55c74c4cfffc24d29a81d9247ee037c5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cdc49312bb62981da7e0424a7987c15a06725540675b6c861aad4997155067e7 +size 37859 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/5eecb26a549cf4b310c939c8e2966d15_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/5eecb26a549cf4b310c939c8e2966d15_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..97d56d36e50c6e67a22e6130b05518510d127c89 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/5eecb26a549cf4b310c939c8e2966d15_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:347eb51463830f85ebe1e9b8e8e399b9aeb81bbc129982e23b95f80e43bf2139 +size 44485 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/5f72bd3c816b7a23c9c86ce70ec2a4bf_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/5f72bd3c816b7a23c9c86ce70ec2a4bf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4e6b099ab40ec0c4214bbe1e4729492a50d562e9 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/5f72bd3c816b7a23c9c86ce70ec2a4bf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a38e380beadad8ab7d0e7b9bf105e7857b0bc8ce7b8ee549d434f6bc6965dc2 +size 83128 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/64a02eb982db722ff96a4adb7792e5bf_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/64a02eb982db722ff96a4adb7792e5bf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f7beabb3ccfc189bfd3611a0eb612fa9e00f1504 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/64a02eb982db722ff96a4adb7792e5bf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd18598cf8f01c4633b840c10f04e48072fafa629e8bc902ebe9ac2c6ffbcbf0 +size 43711 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/64a4a4745842dca46557fc47c9d4716f_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/64a4a4745842dca46557fc47c9d4716f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..749dc995777f66b2a2e8783459fe67b1d69a075f --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/64a4a4745842dca46557fc47c9d4716f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:30076250b6ecd4de3f306292fa982bfbdf89ed890b88167bd6a5a5cbdaf47f15 +size 56881 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/70f97da8ef43e707bb32f7ed0a269665_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/70f97da8ef43e707bb32f7ed0a269665_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..405d93a1be75d8f534b0246741fe523e1ae5c939 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/70f97da8ef43e707bb32f7ed0a269665_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:41dcc4d2eaaaa25dd58e266593cd2d4d879e01c27f7db146891aae206ef1c365 +size 144310 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/71b87d388380993574d17e54e05f1939_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/71b87d388380993574d17e54e05f1939_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7dfd729fa5ad1ed575bd843aa194533bfef2e761 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/71b87d388380993574d17e54e05f1939_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7e07e28719ebd117c94c0daf0846ca68e1decd3e914c5aad0aa9b18b87d88d72 +size 4510 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/87e2ff7a747555c9aa45f4136188bb94_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/87e2ff7a747555c9aa45f4136188bb94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f87cfae8379ad05f07acb84db9668dc0df245e91 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/87e2ff7a747555c9aa45f4136188bb94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ae3e87355997dcaa9f0d550d0a4d16547caf577ba39120a05d221fbc1999c87 +size 4531 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/8bd08dab913d966eb4f19d117ba0d6d9_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/8bd08dab913d966eb4f19d117ba0d6d9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..64f1cca04e239612a9cb75bc4545a9b1f0453040 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/8bd08dab913d966eb4f19d117ba0d6d9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7eda6635ffd165273f2269a3781bd2a4fcb24f5dba497a818984fd21db361105 +size 42027 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/c53595e93e0fd646ebe692734b7757a6_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/c53595e93e0fd646ebe692734b7757a6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..75ee7862623a125dcd55b7743cfdfc2838ade975 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/c53595e93e0fd646ebe692734b7757a6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2250119799444980abb639d38de60d60bd431a1a26e331def9e9a81b855aec30 +size 92762 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/cd644c4cc32c6b5cdb2099f355194261_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/cd644c4cc32c6b5cdb2099f355194261_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5afb06f305359836f42cc57f9934f6569ebab526 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/cd644c4cc32c6b5cdb2099f355194261_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e213374db7697b2371d0975aaea8f945c9f9115786b1e4f687ccd1bd0129b557 +size 4502 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/d98cad5d2aebd1e5370d6d848f56fa93_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/d98cad5d2aebd1e5370d6d848f56fa93_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..715e6c567cae8c9b8d189d60c7aa1f75cac3f0c9 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/d98cad5d2aebd1e5370d6d848f56fa93_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab77c2ffee24d29f802de4c40451e653ae30293d12b3603c9d32bf6ad8875e6a +size 29342 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/dd49aea9f36e0434db7cae93698ff207_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/dd49aea9f36e0434db7cae93698ff207_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0487fb28e828121794d6e174c6b99c8cfda47959 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/dd49aea9f36e0434db7cae93698ff207_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:26026b364f63a7c98b105b6f88e4637f89f964c82f668a40765b1efa5f20e054 +size 33165 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/e1893c9fa0d75477beee7c73a59ca29b_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/e1893c9fa0d75477beee7c73a59ca29b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cb931dabc4e21b2593e492641d993764cfc44e62 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/e1893c9fa0d75477beee7c73a59ca29b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6e789090bf6009dcd9b8dd6cfc0a9f5ddc73895944932808da3e387acc8b9a09 +size 58810 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/e3eb5a2f7f3b19034e8aa0d7ec65f29d_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/e3eb5a2f7f3b19034e8aa0d7ec65f29d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5ec17aa4408786bd246a2e949b7f0e402c2344bb --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/e3eb5a2f7f3b19034e8aa0d7ec65f29d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9c98f92a9e628a076348bbd557c8bb0ba16ec3bfccb4aab19dc5fae1b74787f +size 46326 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/eb561802d98f2fbb5e1bb7295c434aca_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/eb561802d98f2fbb5e1bb7295c434aca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1ab042a5020f4e28be2b9c2aee66a35a5c94d605 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/eb561802d98f2fbb5e1bb7295c434aca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:701f74e161f16c76c35dc3fb42d40111277b3cf9a0f8222b32844abcc8e8deab +size 30743 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/ee8d1fefcdf57f18e2511f68f1a9e75e_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/ee8d1fefcdf57f18e2511f68f1a9e75e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f72e540a2718de03ff41965dac6bc1b42bf54fc7 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/ee8d1fefcdf57f18e2511f68f1a9e75e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f7776f03549c16efb252d4e11cccb2330f3523c4bf4fc6c5c7bd6c6578c26f8e +size 95007 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/f59a4206f53387f2b304bd7fb7dd7e19_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/f59a4206f53387f2b304bd7fb7dd7e19_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..444a399b4bff957efb458dddafb65bf81133675a --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/f59a4206f53387f2b304bd7fb7dd7e19_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a90542417d1df8f91a47b68ee58110ab7665f34b379662386b59153f8a8d0aa6 +size 4458 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/f752841fd2a33644fe419114e8e1ce19_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/f752841fd2a33644fe419114e8e1ce19_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fb044f0ef9502249e5bc2d03d0523cb97f8e9abc --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/f752841fd2a33644fe419114e8e1ce19_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b21f12f3ed75995d1c61bfce142a70a02aa827c58e457ae8c68213cc8bbb95a9 +size 34020 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/ffba376d8af0c6fee0bfa5cba940fe36_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/ffba376d8af0c6fee0bfa5cba940fe36_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..78fb238f68ba2082ab851586edb7f1c64750cf38 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/ffba376d8af0c6fee0bfa5cba940fe36_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d88028c10771c9099cf6ff69cdc54edbcb0092a7d713e85e4397f88efa4d12a2 +size 21987 diff --git a/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/raw.md b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..977709376ac5f2fdabd48595f3709bee42c56951 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00/raw.md @@ -0,0 +1,1469 @@ + + +# --- **O-RAN Working Group 4 (Open Fronthaul Interfaces)** + +## **Cooperative Transport Interface Transport Control Plane Specification** + +Copyright © 2023 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# Contents + +| | | | +|----|-----------------------------------------------------------------------|----| +| 1 | Foreword..... | 4 | +| 2 | Modal verbs terminology ..... | 4 | +| 3 | 1 Scope ..... | 5 | +| 4 | 2 References ..... | 5 | +| 5 | 2.1 Normative references ..... | 6 | +| 6 | 2.2 Informative references ..... | 6 | +| 7 | 3 Definition of terms, symbols and abbreviations..... | 6 | +| 8 | 3.1 Terms ..... | 6 | +| 9 | 3.2 Symbols ..... | 7 | +| 10 | 3.3 Abbreviations..... | 7 | +| 11 | 4 Cooperative Transport Interface (CTI)..... | 9 | +| 12 | 4.1 General Network Architecture and Mechanism..... | 9 | +| 13 | 4.1.1 High Level CTI Message Flow ..... | 10 | +| 14 | 4.1.2 Packet-based Transport Network topologies supported by CTI..... | 11 | +| 15 | 4.1.3 Forwarding and addressing of CTI messages..... | 13 | +| 16 | 4.2 Information Required for Cooperative Transport ..... | 13 | +| 17 | 4.2.1 From O-DU to Transport..... | 13 | +| 18 | 4.2.2 From Transport to O-DU..... | 14 | +| 19 | 4.3 Calculation of CTI reports by O-DU ..... | 14 | +| 20 | 4.3.1 Required load ..... | 14 | +| 21 | 4.3.2 Time interval of the reported load..... | 16 | +| 22 | 4.3.3 Exchange rate of CTI Reporting ..... | 17 | +| 23 | 5 CTI Message Protocol..... | 19 | +| 24 | 5.1 CTI Packet Format..... | 19 | +| 25 | 5.1.1 CTI Message Format..... | 21 | +| 26 | 5.1.2 CTI Common Header ..... | 22 | +| 27 | 5.1.3 CTI Signaling Messages..... | 23 | +| 28 | 5.1.4 CTI Report Body..... | 25 | +| 29 | 5.1.5 CTI Signature ..... | 28 | +| 30 | 5.2 Operation ..... | 28 | +| 31 | 5.2.1 CTI Discovery & Configuration..... | 28 | +| 32 | 5.2.2 Operations ..... | 29 | +| 33 | 5.3 Interface to OSS..... | 31 | +| 34 | 5.3.1 Timers ..... | 31 | +| 35 | 5.3.2 Summary of Objects (Informative) ..... | 31 | +| 36 | 5.4 Examples of the CTI Pattern Descriptor for Fronthaul ..... | 31 | +| 37 | 5.5 Other O-DU Functional requirements..... | 33 | +| 38 | 5.5.1 Reporting scope..... | 33 | +| 39 | 5.5.2 Reporting accuracy..... | 33 | +| 40 | 5.5.3 O-DU CTI performance ..... | 34 | +| 41 | 6 Time alignment between O-DU and Transport..... | 35 | +| 42 | 6.1 Timing architecture options ..... | 35 | +| 43 | 6.2 Resource allocation alignment..... | 35 | +| 44 | 7 Conclusion..... | 38 | +| 45 | 7.1 Summary..... | 38 | +| 46 | 7.2 Open issue list..... | 38 | +| 47 | Annex A CTI Use Cases (Informative) ..... | 39 | +| 48 | A.1 Passive Optical Network (PON) as Transport Technology ..... | 39 | +| 49 | A.1.1 Dynamic Bandwidth Allocation (DBA)..... | 40 | +| 50 | A.1.2 DBA Latency Analysis..... | 40 | +| 51 | A.1.3 Cooperative Dynamic Bandwidth Allocation (CO-DBA)..... | 41 | +| 52 | | | + +| | | | | +|----|-------|---------------------------------------|----| +| 1 | A.1.4 | PON ranging..... | 43 | +| 2 | A.1.5 | PON technologies..... | 43 | +| 3 | A.2 | DOCSIS as a Transport Technology..... | 44 | +| 4 | A.2.1 | DOCSIS resource scheduling..... | 44 | +| 5 | A.2.2 | DOCSIS Latency Analysis..... | 45 | +| 6 | A.2.3 | Bandwidth Report (BWR)..... | 46 | +| 7 | | Revision History ..... | 49 | +| 8 | | History ..... | 49 | +| 9 | | | | +| 10 | | | | + +# --- Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Release xx.yy.zz + +where: + +xx the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). + +yy the second digit-group is incremented when editorial only changes have been incorporated in the document. + +zz the third digit-group included only in working versions of the document indicating incremental changes during the editing process. + +The present document describes the Cooperative Transport Interface (CTI). CTI is an optional interface between O-DUs and Transport Nodes of a packet-based transport network that is used to interconnect the O-DUs to a variety of O-RUs. CTI specifically targets transport Nodes that manage a shared point-to-multipoint access network. Transport nodes (routers and switches) that only manage point-to-point links do not exchange CTI messages with the O-DUs. CTI consists of a CTI Transport Control plane (TC-plane) and a Transport Management (Information Model, Data Model, procedures) (TM). This document specifies the TC-plane. The TM is specified in O-RAN CTI TMP [4]. + +The use of CTI targets packet-based transport networks that contain Transport Nodes (TNs) that terminate one or multiple shared distribution networks, where each distribution network (one port on one TN) aggregates a multitude of Transport Units (TUs). This implies that the bandwidth of a distribution network is shared among multiple TUs. In the upstream direction, the TN manages this sharing by scheduling bandwidth allocations to the multiple TUs. There are two ways to determine how much bandwidth to allocate, either statically or dynamically. Statically (i.e. continuously) granting a fixed bandwidth provides the lowest latency but requires to assign the peak rate. When the bandwidth need is below the peak, the allocated bandwidth is not fully consumed and this difference will be wasted because unavailable for other traffic. On the other hand, dynamically granting bandwidth is typically done with a reactive system in the sense that the bandwidth allocations follow the needs by monitoring the past and present traffic and buffer status. This provides a more efficient multiplexing of multiple traffic streams by maximizing the use of the shared bandwidth, but the reaction time of the system introduces more latency. + +The intent of providing cooperation between the O-DU and the TN over CTI is to make the upstream bandwidth allocation by the TN pro-active by anticipating the bandwidth needs. This is possible in the upstream direction because the O-DU allocates uplink grants to the UEs for slots in the future, based on their requests. Therefore the O-DU is able to notify corresponding future bandwidth needs of the O-RUs based on its granting decisions. The TN is then able to prepare the corresponding bandwidth allocations for the corresponding TUs. The effect is to allow for dynamic bandwidth allocation following the variations of the carried fronthaul traffic (providing statistical multiplexing on the shared network), while minimizing upstream buffering in the TU, hence keeping upstream latency low. It allows for a more efficient use of transport network resources than with a fixed allocation to peak bandwidth values, and for a lower latency than with a purely reactive allocation of bandwidth values by the TN. + +The CTI functionality as such is optional. If an O-DU supports CTI, it has to follow the O-RAN CTI TCP (this document) and O-RAN CTI TMP [4] specifications. + +The uplink latency that CTI aims to limit is specified as “T34max” in O-RAN [2]. + +# 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. +- [2] ORAN-WG4.CUS.0-v11.00, “Control, User and Synchronization Plane Specification”. +- [3] ORAN-WG4.MP.0-v11.00, “Management Plane Specification”. +- [4] ORAN-WG4.CTI-TMP.0-v04.00, “Cooperative Transport Interface Transport Management Procedures Specification” + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [5] ITU-T Study Group 15/Question 2, G.Sup66-201810 , “5G wireless fronthaul requirements in a passive optical network context”. <https://www.itu.int/rec/T-REC-G.Sup66-201907-I> +- [6] Cable Labs CM-SP-LLX-I01-190628, “Low Latency Xhaul over DOCSIS Technology Specification”, Cable Television Laboratories, Inc +- [7] Cable Labs CM-SP-MULPIv3.1-I19-191016, “DOCSIS 3.1 MAC and Upper Layer Protocols Interface Specification” , Cable Television Laboratories, Inc + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [1]. + +New terms used in this document: + +- **CTI client:** a process in the O-DU that exchanges CTI messages to one or multiple CTI servers, e.g. to request a given transport capacity. +- **CTI server:** a process in the Transport Node that exchanges CTI messages with one or multiple CTI clients, e.g. to receive capacity requests. +- **CTI message sender:** CTI client or CTI server generating a CTI message +- **CTI message receiver;** CTI client or CTI server receiving a CTI message + +Generic terms used in this document: + +- **Mobile slot:** a subframe in 3GPP LTE or a slot in 3GPP NR. + +Conventions used in this document: + +- The following convention applies any time a bit field is displayed in a figure. The bit field shall be interpreted by reading the figure from left to right, then from top to bottom, with the MSB being the first bit so read and the LSB being the last bit so read. + +## 3.2 Symbols + +None. + +## 3.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply. + +| | | +|--------|-------------------------------------------------| +| BWR | Bandwidth Reporting | +| CM | Cable Modem | +| CMTS | Cable Modem Termination System | +| CoS | Class of Service | +| CO DBA | Cooperative DBA | +| CTI | Cooperative Transport Interface | +| DBA | Dynamic Bandwidth Allocation | +| DOCSIS | Data Over Cable Service Interface Specification | +| DSCP | Differentiated Services Code Point | +| eAxC | extended Antenna Carrier | +| eNB | e NodeB (applies to LTE) | +| gNB | g NodeB (applies to NR) | +| GNSS | Global Navigation Satellite System | +| HFC | Hybrid Fiber Coax | +| L2 | Layer 2 | +| L3 | Layer 3 | +| LAA | Licensed Assisted Access | +| LBT | Listen Before Talk (applies to LAA) | +| LLID | Logical Link ID | +| LLS | Lower Layer Split | +| MAC | Media Access Control | +| O-CU | O-RAN Central Unit | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| OLT | Optical Line Termination | +| ONU | Optical Networking Unit | + +| | | | +|----|---------------------|------------------------------------------------------| +| 1 | OSS | Operations Support System | +| 2 | PCP | Priority Code Point | +| 3 | PON | Passive Optical Network | +| 4 | PTP | Precision Time Protocol | +| 5 | QoS | Quality of Service | +| 6 | Ra, R1, R2, R3, R4: | eCPRI reference points as shown in Figure 2-9 of [2] | +| 7 | SF | Service Flow | +| 8 | T-CONT | Transmission Container | +| 9 | TC | Traffic Class for IPv6 | +| 10 | Ta3, T34 | Transmission delays as defined in Figure 2-9 of [2] | +| 11 | TC(P) | Transport Control (Plane) | +| 12 | TDM | Time Division Multiplexing | +| 13 | TM(P) | Transport Management (Procedures) | +| 14 | TN | Transport Node | +| 15 | ToS | Type of Service for IPv6 | +| 16 | TPID | Tag Protocol Identifier | +| 17 | TU | Transport Unit | +| 18 | UDP | User Datagram Protocol | +| 19 | UE | User Equipment | +| 20 | VLAN | Virtual LAN | +| 21 | WDM | Wavelength Division Multiplexing | +| 22 | | | + +# 4 Cooperative Transport Interface (CTI) + +## 4.1 General Network Architecture and Mechanism + +With reference to the O-RAN CUS [2] and O-RAN MP [3] specifications, the fronthaul reference architecture is extended to include the cooperative transport interface and transport network, as depicted in Figure 4.1, where the new functions are defined as follows: + +![Figure 4.1: CTI basic reference architecture diagram. The diagram shows the interaction between O-DU, O-RU, Mobile SMO, Transport OSS, and the Transport Network. O-DU contains CUS-plane, M-plane, and TC-plane (CTI client). O-RU contains CUS-plane and M-plane. The Transport Network includes Optional intermediate nodes, TN (with TC-plane CTI server), and TU. Management of CTI in O-DU is shown with a dashed arrow from Mobile SMO to O-DU. Management of CTI in TN is shown with a dashed arrow from Transport OSS to TN. A dashed arrow labeled 'Non-real time exchange of information for coordinating the configuration of specific CTI TM model parameters (interface itself is out of scope)' connects Mobile SMO and Transport OSS. Data flows are indicated by solid and dashed arrows: IIS-C/U/S from O-DU to O-RU, IIS-M from O-DU to TN, and CTI TC-plane from O-DU to TN. TN-TU control and management is shown as an out-of-scope interface between TN and TU.](38cc60bab8b7f31609cf59986ab5ec8d_img.jpg) + +Figure 4.1: CTI basic reference architecture diagram. The diagram shows the interaction between O-DU, O-RU, Mobile SMO, Transport OSS, and the Transport Network. O-DU contains CUS-plane, M-plane, and TC-plane (CTI client). O-RU contains CUS-plane and M-plane. The Transport Network includes Optional intermediate nodes, TN (with TC-plane CTI server), and TU. Management of CTI in O-DU is shown with a dashed arrow from Mobile SMO to O-DU. Management of CTI in TN is shown with a dashed arrow from Transport OSS to TN. A dashed arrow labeled 'Non-real time exchange of information for coordinating the configuration of specific CTI TM model parameters (interface itself is out of scope)' connects Mobile SMO and Transport OSS. Data flows are indicated by solid and dashed arrows: IIS-C/U/S from O-DU to O-RU, IIS-M from O-DU to TN, and CTI TC-plane from O-DU to TN. TN-TU control and management is shown as an out-of-scope interface between TN and TU. + +**Figure 4.1 : CTI basic reference architecture** + +**Cooperative Transport Interface (CTI):** an O-RAN defined interface designed to support real-time and non-real time cooperation between the eNB/gNB and the resource allocation based transport networks. + +**Transport Network:** transfers IIS-C/U/S and IIS-M traffics between O-DU and O-RU. + +**Transport Node (TN):** a master transport network node at O-DU side. A TN schedules one or multiple TUs to perform resource allocation for upstream transmission. It also interfaces with O-DU via CTI and decodes T-plane messages in order to coordinate its own scheduling with forward-looking traffic requirements communicated by O-DU. + +**Transport Unit (TU):** a slave transport network node at O-RU side. The control and management interface between TN and TU is out of scope of this document. + +**CTI TC-plane:** (Transport Control plane). The TC-plane refers specifically to real-time Transport Control between the CTI Client in the O-DU and the CTI Server in the TN.. + +**CTI TM (Transport Management).** The TM Information Model / Data Model model refers to the configuration of parameters for the CTI functionality on the O-DU, and to those CTI configuration parameters that need to be coordinated between mobile SMO and transport network OSS. The purpose of CTI (TC-plane and TM model) is to support cooperation between the O-DU and the TN in the transport network. + +The interface between TN and TU is transport network specific and is out of the scope of this specification. + +Figure 4.2 shows how the CTI relates to the transport network used for fronthaul. The uplink latency $T_{34max}$ is specified between the R3 reference point of the O-RU and the R4 reference point of the O-DU. Note that additionally there could be intermediate nodes (switches or routers) between the O-DUs and TNs (not shown in the figure). These nodes do not interact with the CTI process. However, they can introduce extra latency, which need then to be subtracted from the $T_{34max}$ limit to obtain the resulting latency budget for the TN-TU part of the transport network. + +![Figure 4.2: Detailed view of CTI. This block diagram illustrates the CTI architecture. On the left, multiple User Equipment (UE) units are connected via a 'Radio carrier' to O-RU (Open Radio Unit) blocks. The O-RUs are connected to TU (Transport Units) blocks. These TUs are connected to a 'shared distribution network' which leads into the TN (Transport Network). Inside the TN, there is a 'CTI server'. The TN is connected to an O-DU (Open Distributed Unit) block. A dashed blue arrow labeled 'CTI messages' points from the CTI server to the CTI client within the O-DU. Reference points Ra, Ta3, R3, and R4 are marked along the horizontal axis. A double-headed arrow labeled 'Uplink transport latency T34' spans from R3 to R4.](22818ecb774a3f379eab54476842b2d1_img.jpg) + +Figure 4.2: Detailed view of CTI. This block diagram illustrates the CTI architecture. On the left, multiple User Equipment (UE) units are connected via a 'Radio carrier' to O-RU (Open Radio Unit) blocks. The O-RUs are connected to TU (Transport Units) blocks. These TUs are connected to a 'shared distribution network' which leads into the TN (Transport Network). Inside the TN, there is a 'CTI server'. The TN is connected to an O-DU (Open Distributed Unit) block. A dashed blue arrow labeled 'CTI messages' points from the CTI server to the CTI client within the O-DU. Reference points Ra, Ta3, R3, and R4 are marked along the horizontal axis. A double-headed arrow labeled 'Uplink transport latency T34' spans from R3 to R4. + +Figure 4.2 : Detailed view of CTI + +### 4.1.1 High Level CTI Message Flow + +Figure 4.3 below illustrates a high level view of how CTI works. For simplification only a single O-RU and a single O-DU are shown. The UEs are not shown in this figure. + +![Figure 4.3: Message Flow for CTI in UL Operations. This sequence diagram shows the message flow between O-RU, TU, TN, and O-DU across two time slots. +- At the start of 'Slot n', the O-DU sends a 'CTI message for slot n' (1) to the TN. +- The TN sends 'DL C-plane & U-plane packets for slot n' (2) to the O-RU. +- The O-RU sends 'DL C-plane messages for reception of slot n' (3) to the TU. +- The TU sends 'Grants to TU' (4) to the TN. +- The TN sends 'Amount of UL U-plane (& C-plane) packets for slot n' (5) to the O-DU. +- The O-DU generates 'UL U-plane packets for slot n, generated at symbols X, Y, ... (UL C-plane packets, if present) ...' (6) and sends them to the TU. +- The TU sends 'Grants to TU' (7) to the TN. +- The TN sends 'Amount of UL U-plane (& C-plane) packets for slot n' (8) to the O-DU. +- The process repeats for 'Slot n+1'.](64a4a4745842dca46557fc47c9d4716f_img.jpg) + +Figure 4.3: Message Flow for CTI in UL Operations. This sequence diagram shows the message flow between O-RU, TU, TN, and O-DU across two time slots. +- At the start of 'Slot n', the O-DU sends a 'CTI message for slot n' (1) to the TN. +- The TN sends 'DL C-plane & U-plane packets for slot n' (2) to the O-RU. +- The O-RU sends 'DL C-plane messages for reception of slot n' (3) to the TU. +- The TU sends 'Grants to TU' (4) to the TN. +- The TN sends 'Amount of UL U-plane (& C-plane) packets for slot n' (5) to the O-DU. +- The O-DU generates 'UL U-plane packets for slot n, generated at symbols X, Y, ... (UL C-plane packets, if present) ...' (6) and sends them to the TU. +- The TU sends 'Grants to TU' (7) to the TN. +- The TN sends 'Amount of UL U-plane (& C-plane) packets for slot n' (8) to the O-DU. +- The process repeats for 'Slot n+1'. + +Figure 4.3 : Message Flow for CTI in UL Operations + +The actions and related message exchanges are as follows: + +1. O-DU determines UE grants for slot n. + +2. O-DU sends the CTI message to the TN to request fronthaul bytes for slot $n$ , sufficiently in advance (see Figure 6.1 for background). +3. O-DU sends DL U-plane and C-plane data (packets) for slot $n$ . +4. O-DU sends C-plane data to the O-RU indicating commands for reception of slot $n$ . +5. Upon receiving UL data from its UEs in symbols of slot $n$ , O-RU sends U-plane data (possibly also C-plane data). Data is then buffered in TU until step 6. +6. TN grants to the corresponding TU based on the CTI message. +7. TU transports UL U-plane (and possibly C-plane) packets to the TN when receiving grants from step 6. +8. After transport from TU to TN and from TN to the O-DU, UL U-plane (and possibly C-plane) packets arrive at the O-DU. + +Steps 3 and 4 **may** occur around the same time in any order. Step 2 may occur independently of the time of steps 3 and 4. + +Step 5 occurs per OFDM symbol carrying UL data. The frequency of occurrence of steps 6 + 7 depends on TN implementation. A step 7 is followed by a step 8. + +Note: the symbols which carry data and the symbol duration can vary depending on the use case, this is not shown on this simplified diagram + +Since the O-RU sends the IQ data in the form of U-plane packets every OFDM symbol time rather than queuing the data and sending them at the end of the slot, the TN is able to schedule transport grants each time U-plane packets arrive at the TU. Doing so reduces the latency on the transport link, compared to scheduling grants only at the end of a slot. The frequency of the transport grant is up to the TN implementation (each grant can provide transport network resource for fronthaul packets pertaining to 1 symbol, more than 1 symbol, or a slot), and depends in part on the granularity of the TN scheduling interval. + +### 4.1.2 Packet-based Transport Network topologies supported by CTI + +The simplest way to provide connectivity for Fronthaul is to provide one point-point link (e.g. optical fiber) between each O-RU network interface and its corresponding O-DU. One O-DU can serve multiple O-RUs, and each O-RU can have multiple network interfaces and multiple radio carriers (which may also be known as cells). The upstream radio traffic in the radio carriers is scheduled by O-DU schedulers. In such case there is no sharing of transport resources, each connection has its dedicated bandwidth and physical link, the CTI mechanism is not required. + +![Diagram illustrating direct interconnections between multiple O-DUs and multiple O-RUs over point-point links. The diagram shows six O-RUs (O-RU 1 to O-RU 6) on the left, each connected to one or more O-DUs on the right. O-RU 1 and O-RU 2 connect to O-DU k. O-RU 3 and O-RU 4 connect to O-DU l. O-RU 5 connects to O-DU k and O-DU l. O-RU 6 connects to O-DU k and O-DU l. Each O-RU has a physical port 'A' and a mobile scheduler for radio carrier 'k'. The diagram also shows radio carriers 'k' and 'l' for each O-RU. Fronthaul flows are indicated by dotted lines for O-RU 1 and O-RU 2, and dashed lines for O-RU 3, O-RU 4, O-RU 5, and O-RU 6. A legend at the bottom left defines the symbols: 'A' for Physical port 'A', 'k' for Mobile scheduler for radio carrier 'k', 'k' for Radio carrier 'k', dotted lines for Fronthaul flow, and dashed lines for Fronthaul flow.](156eb7360e6eeb4a3d210dfecb6833c8_img.jpg) + +Diagram illustrating direct interconnections between multiple O-DUs and multiple O-RUs over point-point links. The diagram shows six O-RUs (O-RU 1 to O-RU 6) on the left, each connected to one or more O-DUs on the right. O-RU 1 and O-RU 2 connect to O-DU k. O-RU 3 and O-RU 4 connect to O-DU l. O-RU 5 connects to O-DU k and O-DU l. O-RU 6 connects to O-DU k and O-DU l. Each O-RU has a physical port 'A' and a mobile scheduler for radio carrier 'k'. The diagram also shows radio carriers 'k' and 'l' for each O-RU. Fronthaul flows are indicated by dotted lines for O-RU 1 and O-RU 2, and dashed lines for O-RU 3, O-RU 4, O-RU 5, and O-RU 6. A legend at the bottom left defines the symbols: 'A' for Physical port 'A', 'k' for Mobile scheduler for radio carrier 'k', 'k' for Radio carrier 'k', dotted lines for Fronthaul flow, and dashed lines for Fronthaul flow. + +**Figure 4.4 : Direct interconnections between multiple O-DUs and multiple O-RUs over point-point links** + +Things change when a packet-based transport network is used to interconnect the O-DUs and their corresponding O-RUs. The use of CTI targets transport networks that contain Transport Nodes (TNs) that terminate one or multiple shared distribution networks, where each distribution network (one port on one TN) aggregates multiple Transport Units (TUs). This implies that the bandwidth of a distribution network is shared among multiple TUs. In the upstream direction, the TN manages this sharing by scheduling bandwidth allocations to the multiple TUs. + +The concept of CTI can be applied to inform the relevant Transport Nodes (TN) of the required uplink traffic load and traffic timing that each O-RU to O-DU connection will have to carry. There is a need to uniquely identify the corresponding connection in each traffic request being signaled over CTI. This identifier is added by the O-DU, and shall be commonly known by both the O-DU and TN. However, the identifier should be agnostic of any TN-technology-specific parameters in order to maintain general applicability of the concept to any technology. The TN then has the responsibility to translate this generic identifier into its own technology-specific parameters, e.g. a Transmission Container (T-CONT) or Logical Link ID (LLID) for PON (the TN being an OLT) or a Service Flow (SF) for DOCSIS (the TN being a CMTS). + +The uniqueness of the identifier shall allow for multiple architecture use cases, whereby the O-DU should not be dependent on the underlying Transport Network topology. The different architecture use cases are illustrated in Figure 4.5. Basically, O-DUs and TNs may be connected in multiple ways (each O-DU may connect to multiple TNs, each TN may connect to multiple O-DUs). + +![Figure 4.5: Possible interconnections between multiple O-DUs and multiple O-RUs over a transport network consisting of a multitude of Transport Nodes (TNs) and their corresponding shared distribution networks with multiple Transport Units (TUs).](c53595e93e0fd646ebe692734b7757a6_img.jpg) + +The diagram illustrates various interconnection scenarios between O-RUs, TUs, TNs, and O-DUs. On the left, O-RUs (1-6) are shown with radio carriers (k, l) and physical ports (A, B). These connect to TUs, which are linked to a 'Shared distribution network'. The network then connects to one or more TNs. Finally, the TNs connect to one or more O-DUs. The O-DUs contain CTI clients and servers. Information flows are indicated: 'Info for TN scheduler' (dashed blue arrow from O-DU to TN), 'CTI report messages' (dashed blue arrow from TN to O-DU), and 'Info from O-DU scheduler and other processes' (dashed blue arrow from O-DU to TN). A legend defines symbols: 'A' for Physical port 'A', 'k' for Mobile scheduler for radio carrier 'k', 'k' for Radio carrier 'k', yellow circle for CTI client (in O-DU), orange circle for CTI server (in TN), green circle for TN scheduler, and green circle for Entity in TU scheduled by TN, for fronthaul flow. Dotted lines represent fronthaul flow, and solid lines represent fronthaul flow. + +Figure 4.5: Possible interconnections between multiple O-DUs and multiple O-RUs over a transport network consisting of a multitude of Transport Nodes (TNs) and their corresponding shared distribution networks with multiple Transport Units (TUs). + +**Figure 4.5 : Possible interconnections between multiple O-DUs and multiple O-RUs over a transport network consisting of a multitude of Transport Nodes (TNs) and their corresponding shared distribution networks with multiple Transport Units (TUs).** + +Basically, a “fronthaul traffic flow” is a flow of packets that requires a given capacity and latency limit. A unique identification is needed in the TN to convert a request for a fronthaul traffic flow into a scheduling action on the corresponding managed entity (Traffic Container / alloc-ID or Logical Link ID in PON or Service Flow in DOCSIS) on the corresponding TU (PON ONU or DOCSIS CM). + +The unique identification consists of two parts. The first is called “CTI Session ID” and refers uniquely and globally to a specific O-RU physical interface (used by one or multiple radio carriers). In case there is no differentiation beyond the O-RU physical interface, the CTI Session ID is sufficient. The second is called “Flow ID”, which allows to differentiate and report different fronthaul flows per CTI session. The CTI Flow ID is unique only within the context of its CTI Session ID, the same CTI Flow IDs may be re-used across different sessions. See section 5 for more details. + +Examples of using the CTI Session ID and CTI Flow ID are shown in Figure 4.5: + +- O-RU 1: 1:1 mapping between one O-DU scheduler and one O-RU interface (single radio carrier instance), carrying a single flow. A single CTI Session ID is sufficient. A single report is communicated. +- O-RU 2: 1:1 mapping between one O-DU scheduler and one O-RU interface (single radio carrier instance), carrying multiple flows. A single CTI Session ID is sufficient. Multiple reports with different Flow IDs may be used to differentiate the flows. +- O-RU 3 and O-RU 4: Multiple O-RUs being served by a single TU, each with 1:1 mappings between an O-DU scheduler and an O-RU interface. Each O-RU has one different CTI session ID. + +- O-RU 5: N:1 mapping between multiple radio carrier instances (e.g. multiple sectors, multiple frequency bands) and one O-RU interface. A single message may be used, with a single CTI Session ID reporting the sum of the different radio carrier loads. Alternatively, multiple messages (from a single or from multiple CTI clients) may also be used, which are then interpreted together by the TN. +- O-RU 6: Multiple 1:1 mappings between one O-DU scheduler and one O-RU interface, on the same O-RU and TU. One CTI Session ID is used per O-RU interface. + +#### Notes + +- These high-level use cases may also be combined together (e.g. Multiple flows on multiple O-RU interfaces). The protocol also supports such combined use cases. +- The use case of multiple network interfaces per radio carrier (for bonding or redundancy purposes) is out of scope of this version on CTI. This specification only considers a single network interface per radio carrier. In case of multiple radio carriers, it is assumed in this specification that each uses a single O-RU network interface (which could be the same as the other radio instances, or a dedicated one (like O-RU 6 in Figure 2-5)). +- The CTI client side generating the CTI reports may be implemented as multiple instances per O-DU. +- The CTI server side treating the CTI reports may be implemented as multiple instances per TN. + +There are two possible ways to populate the CTI Session IDs in the O-DUs and TNs, either statically by means of preconfiguration via their OAM systems, or dynamically by means of an auto-discovery mechanism (see section 5.2.1). The CTI operation between the O-DU and the TN is specified independently of the configuration method of the CTI Session IDs. + +### 4.1.3 Forwarding and addressing of CTI messages + +The CTI messages generated by a CTI instance in the O-DU shall be forwarded to and addressed to the corresponding CTI peer in the corresponding TN. Depending on the interconnection between the O-DUs and the TNs, CTI messages are encapsulated at Layer 2 or at Layer 3: + +- Point to point links; Layer 2 or Layer 3 +- Ethernet switches; Layer 2 or Layer 3 +- IP Routers; Layer 3 + +Encapsulation details are described in section 5.1. + +## 4.2 Information Required for Cooperative Transport + +### 4.2.1 From O-DU to Transport + +The O-DU needs to convey the bandwidth needs per O-RU interface per time interval with a unique identifier of the traffic being reported. There is also the option to convey information about load patterns inside the reported time interval. + +A report carries the following information; + +- Time interval End (time at which all fronthaul packets pertaining to that time interval have been sent by the O-RU) +- Time interval Start (time at which fronthaul packets pertaining to that time interval start to be sent by the O-RU) +- CTI Session ID + optionally Flow ID +- Required load for the time interval of the session (and flow in the session) + +The TN needs to correlate the unique identification (CTI Session ID + optionally Flow ID) to a corresponding unique traffic container on a corresponding TU. The TN needs to interpret the required load and convert it to bandwidth allocations corresponding to the reported time interval. + +The TN should also be aware of the latency budget it has available per O-RU interface (or per flow per O-RU interface in case of differentiation between multiple flows). This is the portion of T34max for the TN-TU segment. It allows the TN to give relative priorities between the fronthaul connections it manages. As this parameter is a fixed value, it is not carried in CTI messages but should be configured on the TN by its OAM. + +### 4.2.2 From Transport to O-DU + +Uplink CTI messages may be used for the specific case of notification of PON ranging (see Annex A.1.4 for background on PON ranging). The uplink interruptions caused by PON ranging will be felt in the O-DU as jitter or packet drop on the upstream fronthaul packets. In worst case, the interruptions can be in the order of several hundreds of $\mu$ s. + +Such relatively short interruptions will not cause an outage of the radio system (no action by the network, no radio link interruption), but can still have detrimental effects, depending on whether the data is protected by HARQ and on the way the O-DU would react to the perceived jitter or loss. + +However, an adaptive RAN scheduler might conclude the degradation is due to an impaired radio channel, which would be inappropriate and could lead to wrong reactions by the O-DU, further degrading performance. To avoid this, the O-DU can benefit from knowing when the uplink is subject to interruptions due to the transport network. + +A specific CTI signaling message is defined in section 5.1.3.1 that allows the TN (OLT) to notify the O-DU about an upcoming ranging event. One event has a maximum duration and contains a series of interruptions. A PON ranging notification carries the following information; + +- Event start and Maximal Event duration in which ranging interruptions will occur +- Maximal duration per interruption (corresponding to the quiet window size on the PON) +- List of CTI Session IDs impacted by the ranging event + +The CTI Server in the TN (OLT) sends a ranging notification for a PON to every CTI Client that manages one or multiple CTI sessions on that given PON. + +The notification message has to arrive at the O-DU at least 10 ms in advance of the event. The O-DU is free to apply whatever proprietary action after reception of the ranging notifications. + +![Figure 4.6: Notification of PON ranging upstream interruptions. The diagram shows a timeline of U/S bandwidth availability and ranging events. A blue line represents 'Availability PON U/S bandwidth'. Grey shaded regions represent 'Ranging event (X new ONUs)' and 'Ranging event (Y new ONUs)'. A double-headed arrow indicates the 'Quiet window size'. A horizontal double-headed arrow below the timeline shows the 'Repetition of ranging events (every X s)'. Two yellow diamonds represent 'Ranging event message OLT -> O-DU' with a duration of '> 10ms'.](21d74dce0861e0a807f4f544a0368035_img.jpg) + +Figure 4.6: Notification of PON ranging upstream interruptions. The diagram shows a timeline of U/S bandwidth availability and ranging events. A blue line represents 'Availability PON U/S bandwidth'. Grey shaded regions represent 'Ranging event (X new ONUs)' and 'Ranging event (Y new ONUs)'. A double-headed arrow indicates the 'Quiet window size'. A horizontal double-headed arrow below the timeline shows the 'Repetition of ranging events (every X s)'. Two yellow diamonds represent 'Ranging event message OLT -> O-DU' with a duration of '> 10ms'. + +**Figure 4.6 : Notification of PON ranging upstream interruptions** + +## 4.3 Calculation of CTI reports by O-DU + +### 4.3.1 Required load + +Uplink fronthaul traffic from O-RU to O-DU can consist of U-plane, C-plane, and M-plane packets. The load reporting by CTI has to allow the TN to follow the traffic variations over time, but this needs prediction of this traffic. + +#### 4.3.1.1 U-plane + +The U-plane uplink traffic can be predicted by the O-DU based on the decisions made by the RAN schedulers and other processes. As the TN only handles aggregate traffic from the O-RUs, the O-DU shall provide information about the aggregate traffic load over all UEs per O-RU interface (and optionally per flow per O-RU interface) at a given time interval. The prediction accuracy depends on the capability of the O-DU to estimate the processes (e.g. compression) done by the O-RU. The O-DU shall take enough margin so as to not underestimate the actual traffic being generated (underestimation leads to accumulated buffering hence latency and loss). On the other hand, the O-DU should keep the margin as low as possible in order to reduce overestimation (overestimation reduces the efficiency of the transport system). + +The CTI protocol allows for differentiating between different flows on the same O-RU interface. Each flow is linked to a Layer 2 and/or Layer 3 mapping. + +For cases where one O-RU (or O-RU interface) aggregates fronthaul traffic from multiple RAN schedulers (e.g. multiple sectors), the O-DU shall be able to report the full traffic load for the O-RU (or O-RU interface) in an aggregated message, or in separate messages, and the TN has to interpret all information for the O-RU (or O-RU interface). + +#### 4.3.1.2 C-plane + +Uplink C-plane messages are not present except for the special case of Licensed Assisted Access (LAA). If LAA is used, the C-plane uplink traffic consists of messages for Listen Before Talk (LBT). LBT is performed per carrier. There can be more than one carrier per RU. It is expected that typical deployments will be maximum 4 carriers. The LBT process depends on the channel utilization and is hence unpredictable, but it is possible to determine the following worst-case assumptions: + +- Repetition of LBT\_PDSCH\_RSP every subframe (1ms) of (message size 25 Bytes). With max 4 carriers this gives 4 such messages per subframe. +- Repetition of the other messages LBT\_DRS\_RSP, LBT\_Buffer\_Error, LBT\_CWCONFIG\_RSP (message sizes of 21 Bytes) is much less, the assumption is one of those messages every subframe (1ms) +- Assuming transport over UDP/IPv4/tagged Ethernet gives encapsulation overhead of 50 Bytes per message +- Full burstiness; the O-RU sends these 5 messages back-to-back close to the end of the subframe, but exact timing can vary. +- The average C-plane uplink load is 3 Mbit/s per O-RU. + +In terms of latency, there are two aspects to take care of. First, the typical latency requirement for LBT C-plane messages themselves is 0.5ms (minus some margin for processing). Second, the presence of uplink C-plane messages may not push the latency of uplink U-plane messages above their tolerance threshold. + +There are two ways to accommodate for the uplink C-plane messages; + +##### Including C-plane traffic in CTI messaging + +The C-plane may be part of the CTI reporting when the CTI client continuously adds a certain fixed bandwidth (eg based on the above worst-case example) for the C-plane traffic in all its reports. The advantage is that the transport network does not need to be aware of the nature of such traffic and does not need extra configuration, and the O-DU can use a simple constant term in its calculations. + +Such allocated bandwidth for C-plane messages shall ensure that they are not buffered too long, so that their latency is respected (assuming 0.45ms for including processing time). In the example above this requires to include enough extra bandwidth in each report to transmit 3 Mbit/s in less than 0.45ms, being an extra bandwidth of at least 6.6 Mbit/s. (Because the exact timing of the LBT messages is not known, even if the CTI reporting would be more frequent than the frequency of LBT messages (1ms), it would not be accurate to estimate which report would be capturing the LBT messages, so the extra bandwidth shall be granted in each report). + +The impact of C-plane on U-plane latency is due to the sharing of the same TU buffer for U-plane and C-plane packets, and the TDM nature of the transport network (bandwidth allocation is not (fully) done by line rate adjustment but (also) by TDM burst adjustment). C-plane packets in the head of the queue will impact U-plane packets behind them. U-plane traffic typically has stricter transport latency requirements than the 0.5ms (or 0.45ms) for the C-plane traffic. + +- If the U-plane bandwidth gets small compared to the C-plane bandwidth and the combined allocated bandwidth is just their sum, then the C-plane packets could block the U-plane packets behind them for too long before being transmitted. Hence a floor value of allocated bandwidth (even if U-plane traffic would be very low) could be needed. +- Most of the time the U-plane traffic is much higher than the C-plane traffic, but even so if the allocated bandwidth is just the sum of C- and U-plane traffic, the U-plane traffic could need more TDM bursts to be fully transmitted than without the C-plane traffic. This increases latency. Using a higher value than the actual C-plane traffic as the extra term in the CTI report calculation could be needed to reduce this impact. This has to be estimated depending on the technology of the Transport network and the latency requirements. + +In summary, this approach may be chosen by configuring at the CTI client (per CTI session ID) a parameter for a fixed extra bandwidth (#bytes to be added per report) and a parameter for a minimum total bandwidth (minimum #bytes to be used per report independently of the actual need). The CTI server and TN is not aware of the differences between U-plane and C-plane. + +##### Separate transport flows for uplink C-plane traffic and uplink U-plane traffic + +Alternatively, for full latency isolation of C-plane and U-plane traffic, the transport system may offer a dedicated and fixed uplink transport channel that can be used for LBT messages. The C-plane packets would have to be uniquely identified for classification to the transport flow (eg by means of PCP or DSCP marking). The C-plane traffic is then decoupled from the CTI reporting, CTI only handles U-plane uplink traffic in CTI-controlled transport channel. The U-plane traffic will not share the same TU buffer and will experience latency impact from the C-plane traffic. + +The transport system should provide a dedicated bandwidth to the C-plane transport channel that provides sufficiently low latency. This requires the O-RU to be configured to apply differentiated marking between C-plane and U-plane traffic, and coordination between Transport and Mobile management systems to configure an appropriate value of the dedicated C-plane transport channel bandwidth. In CTI messages there is no need to take C-plane traffic into account, so the fixed extra bandwidth and minimum total bandwidth may be set to 0 in the configuration of the CTI client. + +#### 4.3.1.3 M-plane + +The M-plane uplink traffic is not fully predictable by the O-DU. However, that traffic is much less latency-sensitive and can be differentiated by different Layer 2 or Layer 3 marking from U-plane and C-plane. It may be kept out of CTI reporting and transported separately from the U-plane and C-plane traffic by the TN. + +### 4.3.2 Time interval of the reported load + +The TN shall be informed about the time interval in which the reported load will be arriving at the TU interface. Each CTI message can carry the start and end of uplink fronthaul transmission on the O-RU R3 interface (please see section 5.1.4.2 and 5.1.4.3). + +There is an inherent O-RU latency $Ta_3$ between the antenna interface $Ra$ and the uplink reference point $R3$ , characterized by the O-RU category with a margin of $20\mu s$ or $50\mu s$ (See Table B-5 in O-RAN CUS [2]). The O-DU is aware of the category per O-RU. + +In CTI a time of day is communicated as a Base time (granularity in ns) + an Offset (granularity in $\mu s$ ), see section 5.1.4.1. + +Accuracy of time references (Base + Offset) shall be better than half the category margin, namely $10\mu s$ ( $-5\mu s/+5\mu s$ ). + +### 4.3.3 Exchange rate of CTI Reporting + +#### 4.3.3.1 Equipment capability (CTI\_MIN) + +Depending on the implementation, the CTI Client(s) on an O-DU can be limited by a maximum generation rate of CTI messages, and the TN can be limited by a maximum reception rate of CTI messages. When using a given combination of O-DU and TN, the applied CTI message exchange rate shall be supported by both sides. + +In order to select a workable CTI exchange rate between a given O-DU and a given TN, the supported capability of the O-DU and TN has to be known. This is expressed as a performance parameter CTI\_MIN for the O-DU and for the TN. CTI\_MIN represents the minimal supported spacing between two CTI messages. When an equipment supports a given CTI\_MIN, higher values shall also be supported. The CTI\_MIN values can be categorized as in Table 2-1. For example a device with CTI\_MIN higher than 0.5ms and lower or equal to 1 ms falls in category 3. It shall also be able to behave as a device of category 1 or 2. + +**Table 2.1 : CTI message rate categories for O-DU or TN** + +| Category | Capability of equipment:<br>supported message interval | +|----------|--------------------------------------------------------| +| 1 | 5 ms | +| 2 | 2 ms | +| 3 | 1 ms | +| 4 | 0,5 ms | +| 5 | 0,25 ms | + +When a CTI\_MIN value is specified at O-DU level, it means all active CTI clients on the O-DU shall support the rate, e.g. when multiple clients are used for a same Session ID they have to operate at the same message exchange rate. Alternatively CTI\_MIN can be specified per CTI client instance. + +Note that a category only represents a capability, it does NOT mandate the use of that particular value as actual CTI message exchange rate. The selection of the actual rate is described hereunder. + +#### 4.3.3.2 Determining common nominal CTI rate (CTI\_NOM) + +A common CTI rate shall be selected for a given combination of O-DU and TN and a given mobile slot duration. The common rate is a nominal value for the spacing between two messages, expressed as CTI\_NOM. + +In principle, the maximum CTI exchange rate that is ever needed is one reporting message per mobile slot duration, as this is the granularity at which the RAN schedulers can allocate traffic. But such high exchange rate will not always be possible or even needed. If the common CTI rate is less than once per every mobile slot, multiple mobile slots have to be grouped in the same CTI reporting message, so CTI\_NOM shall always follow an integer number ( $N \geq 1$ ) of mobile slot units. CTI\_NOM shall comply to both of the following: + +- 1) Shall be supported by O-DU and TN: + +$$CTI\_NOM \geq \max(CTI\_MIN(O-RU), CTI\_MIN(TN))$$ +- 2) Shall be a multiple of mobile slot duration: + +$$CTI\_NOM = N \times (\text{mobile slot duration}), \text{ where } N \text{ is a non-zero integer, and depends on the latency requirements.}$$ + +Example: Assuming a mobile slot of 0.5ms, if an O-DU supports a CTI\_MIN of 0.5ms and a TN supports a CTI\_MIN of 1ms, the fastest common CTI exchange rate would be $CTI\_NOM = 1\text{ms}$ (containing 2 mobile slots). However, if the required latency can still be reached by applying a higher CTI\_NOM like 1.5ms (3 mobile slots) or 2ms (4 mobile slots), it is allowed to use such larger values as well. + +CTI\_NOM has to be interpreted as follows: + +- If no load is to be reported for some period, CTI messages don't need to be sent at CTI\_NOM rate, so the spacing may be larger. Keepalives are still exchanged periodically in any case. See section 5.2.2 for background. + +- CTI\_NOM represents an average rate and not a strict message spacing, there may be some jitter on CTI messages themselves, see section 4.2 for background. + +The sequence number inside each CTI message can be used to detect the drop of a CTI message. Further actions for missing or out-of-order sequence numbers are not specified in this specification. + +# 5 CTI Message Protocol + +This section describes the mandatory functions of the CTI protocol. Figure 5.1 is a reference diagram that includes the ORAN system and transport system functional blocks. The transmission system could be a PON or DOCSIS transport system. + +![Figure 5.1 : Fronthaul Reference Diagram. This block diagram shows the architecture of the ORAN system and transport system. From left to right: an antenna icon connects to an O-RU (orange box) via an 'Air Interface' (labeled 'N'). The O-RU connects to a TU (green box) via a 'Network Interface' (labeled 'N'). The TU connects to a TN (green box) via a 'Transport Network' (labeled 'N:1'). The TN connects to an O-DU (orange box) via a 'CTI' interface (labeled 'N:N'). The O-DU connects to an O-CU (orange box), which then connects to a 'Mobile Core' (orange box). A dashed red arrow labeled 'CTI' points from the O-DU to the TN. A double-headed arrow labeled 'Fronthaul' spans the connection between the O-RU and the O-DU.](eb561802d98f2fbb5e1bb7295c434aca_img.jpg) + +Figure 5.1 : Fronthaul Reference Diagram. This block diagram shows the architecture of the ORAN system and transport system. From left to right: an antenna icon connects to an O-RU (orange box) via an 'Air Interface' (labeled 'N'). The O-RU connects to a TU (green box) via a 'Network Interface' (labeled 'N'). The TU connects to a TN (green box) via a 'Transport Network' (labeled 'N:1'). The TN connects to an O-DU (orange box) via a 'CTI' interface (labeled 'N:N'). The O-DU connects to an O-CU (orange box), which then connects to a 'Mobile Core' (orange box). A dashed red arrow labeled 'CTI' points from the O-DU to the TN. A double-headed arrow labeled 'Fronthaul' spans the connection between the O-RU and the O-DU. + +**Figure 5.1 : Fronthaul Reference Diagram** + +The O-RU can have one or more carriers (e.g., multiple antennas, multiple sectors), each corresponding to one eAxC and one RAN scheduler. One RAN scheduler can manage multiple carriers. The O-RU can also have one or more network interfaces between itself and the TU. The O-RU is responsible for associating byte streams from each carrier (antenna/sector) to a unique network interface. The CTI message describes the byte flow across a single network interface. + +Requirements are only listed for the ORAN components. This document provides the expectation on the transport network. Any parameter quoted as having a value “N” is a variable that is unique per usage. Note that N:1 and N:N in the above figure indicate many to 1, and many to many relations, respectively. + +## 5.1 CTI Packet Format + +The bit order and Byte order in which all CTI messages are transported shall follow the order shown in Figure 5.2. + +![Figure 5.2 : Order of transmission of CTI messages. This diagram illustrates the bit and byte order for CTI messages. The top part shows a horizontal sequence of bits from 0 (msb) to 7 (lsb), with an arrow indicating 'Bits transmitted left-to-right'. The bottom part shows a vertical stack of octets from Octet 1 (msB) to Octet N (lsB), with an arrow indicating 'Octets transmitted top-to-bottom (big endianness)'.](435cccc6bd742b3a885c4ec296a3fe69_img.jpg) + +Figure 5.2 : Order of transmission of CTI messages. This diagram illustrates the bit and byte order for CTI messages. The top part shows a horizontal sequence of bits from 0 (msb) to 7 (lsb), with an arrow indicating 'Bits transmitted left-to-right'. The bottom part shows a vertical stack of octets from Octet 1 (msB) to Octet N (lsB), with an arrow indicating 'Octets transmitted top-to-bottom (big endianness)'. + +**Figure 5.2 : Order of transmission of CTI messages** + +The O-DU shall support Ethernet II as Layer 2, including the tagging aspects: + +- untagged Ethernet +- single tagged (802.1Q) Ethernet +- dual-tagged (802.1ad) Ethernet + +Use of Ethernet by the O-DU is mandatory. The choice of tagging is left to the operator. + +Support of IPv4 as Layer 3 is mandatory in the O-DU. Use of IPv4 or IPv6 by the O-DU is optional. When IPv4 or IPv6 is used, CTI is carried over UDP. + +The CTI messages are exchanged between the CTI client located in the O-DU and the CTI server located in the TN. A message is either sent from the O-DU to the TN or from the TN to the O-DU. + +The CTI client and CTI server shall format the CTI messages specified in Figure 5.3 and Table 5.1, Table 5.3, and Table 5.7. + +![](70f97da8ef43e707bb32f7ed0a269665_img.jpg) + +| | | | | +|-------------------------------|--------------------------|--------------------|---------------------------| +| 6 bytes | Ethernet DA | | | +| 6 bytes | Ethernet DA | Ethernet SA | | +| 4 bytes for 802.1Q | Ethernet SA | | | +| 8 bytes for 802.1ad | VLAN Header | | | +| ----- | | | | +| 4 bytes | Ethertype = ORAN | | Subtype = CTI | +| OR | | | | +| 2 bytes | Ethertype = IPv4 or IPv6 | | | +| 20 bytes for IPv4 (shown), or | Ver | IHL | TOS | +| 40 bytes for IPv6 (not shown) | Identification | | 0 D M F F Fragment Offset | +| (Prior to extension headers) | Time to Live | | Protocol | +| 8 bytes | UDP Source Port | | UDP Dest Port | +| | UDP Length | | UDP Checksum | +| ----- | | | | +| 8 bytes | V | R | H S | +| | Sequence | | CTI Session ID | +| | CTI Session ID | | | +| ----- | | | | +| 3 bytes | Msg Type | | Length | +| variable bytes | | | Parameters | +| | Parameters | | | +| OR | | | | +| 9 bytes | CTI Base Seconds | | | +| | CTI Base Nanoseconds | | | +| | Table Size | | | +| 6 bytes | Type 1 Report Entry | Flow ID | End Time Offset | +| | | Bytes Requested | | +| 6 bytes | Type 1 Extension | 0xFF | Start Time Offset | +| | | Pattern Descriptor | | +| 6 bytes | Type 2 | 0xFE | CTI Msg Gen Time | +| | | Reserved | | +| ----- | | | | +| TBD bytes | CTI Signature (Optional) | | | +| ----- | | | | +| 4 bytes | Ethernet CRC | | | + +**CTI Common Header** + +**CTI Signaling Body** + +**CTI Report Body** + +**CTI Signature** + +Figure 5.3 : CTI Message Format. + +The message is either transported over UDP/IP over Ethernet (using IPv4 or IPv6 Ether type), or directly over Ethernet (using O-RAN Ether type and O-RAN Protocol subtype). + +When IP is not used, the fields are (example for 802.1Q): + +- Ethernet MAC destination address is the MAC address of the CTI message receiver +- Ethernet MAC source address is the MAC address of the CTI message sender +- 802.1Q TPID value 0x8100 which indicates the presence of a VLAN header +- 802.1Q PCP is determined by configuration +- 802.1Q VLAN ID is determined by configuration +- EtherType has value of 0x9433, dedicated for use by O-RAN. +- A 2-byte Protocol subtype. The protocol subtype for CTI is 0x0001. + +When IP is used, the fields are (example for 802.1Q): + +- Ethernet MAC destination address is the MAC address of the CTI message receiver corresponding to its IP address (or the interface of the next hop router) +- Ethernet MAC source address is the MAC address of the CTI message sender corresponding to its IP address (or the interface of the last hop router) +- 802.1Q TPID value 0x8100 which indicates the presence of a VLAN header if it is included +- 802.1Q PCP is assigned by the operator +- 802.1Q VLAN ID is assigned by the operator +- EtherType is value 0x0800 (IPv4) or 0x86DD (IPv6) +- IPv4 ToS / IPv6 TC is assigned by configuration +- IPv4 Protocol Field = UDP ; IPv6 Next Header Field = UDP +- the IP source address is the IP address of the sender +- the IP destination address is defined by the sender's OSS System +- the UDP source port is defined by the sender's OSS System, and +- the UDP destination port is defined by the sender's OSS System + +The contents of the payload (Ethernet or UDP) contain the CTI message elements as described in Table 5.1, followed by an optional CTI Signature, as defined in Section 5.1.5. *The optionality of the CTI Signature and how it is configured is for a future release of this specification.* + +For processing simplicity at TN, a CTI message shall not be fragmented over multiple packets or frames. + +*Note that the configuration of L2/L3 parameters for CTI transport is described in O-RAN CTI TMP [4].* + +### 5.1.1 CTI Message Format + +A CTI message either conveys CTI reports or CTI signaling. In both cases, the message has a common message header. For CTI report (CTI-Report) message, the CTI message common header is followed by a single report body. For CTI signaling (CTI-Signaling) message, the CTI message common header is followed by single signaling body, as shown in Figure 3-4. + +![Figure 5.4: Structure of CTI-Signaling Messages and CTI-Report Messages. The diagram shows two message structures. On the left, a 'CTI-signaling message' consists of a 'CTI message common header' and a 'CTI-signaling message body'. On the right, a 'CTI-report message' consists of a 'CTI message common header' and a 'CTI-report message body'.](ffba376d8af0c6fee0bfa5cba940fe36_img.jpg) + +Figure 5.4: Structure of CTI-Signaling Messages and CTI-Report Messages. The diagram shows two message structures. On the left, a 'CTI-signaling message' consists of a 'CTI message common header' and a 'CTI-signaling message body'. On the right, a 'CTI-report message' consists of a 'CTI message common header' and a 'CTI-report message body'. + +**Figure 5.4 : Structure of CTI-Signaling Messages and CTI-Report Messages** + +A CTI report body may contain one or more report entries. Each report entry describes one CTI flow or one Pattern of one CTI flow. A CTI flow could correspond to a CoS. A CTI report body can describe: + +- One or more mobile slots with a single report entry +- More than one mobile slots with multiple report entries +- One or more flows within a mobile slot by using multiple report entries +- One of more flows across multiple mobile slots by using multiple report entries + +The typical packet length would be as follows. + +- (22+20+8+8+9+6) 73 bytes for IPv4 over 802.1Q, 1 CTI Type 1 Row with no CTI Type 1 Extension Row and no CTI Signature +- (22+20+8+8+9+4\*6) 91 bytes for IPv4 over 802.1Q, 4 CTI Type 1 Rows with no CTI Type 1 Extension Row and no CTI Signature +- (22+40+8+8+9+4\*6) 111 bytes for IPv6 over 802.1Q, 4 CTI Type 1 Rows with no CTI Type 1 Extension Row and no CTI Signature + +### 5.1.2 CTI Common Header + +**Table 5.1 : CTI Message Common Header** + +| Information Element | Size | Description | +|------------------------------------|---------|--------------------------------------------------------------------------------------| +| <b>CTI Common Header (8 bytes)</b> | | | +| Protocol Version | 4 bits | Version number of CTI message | +| Reserved | 2 bits | Reserved. Sender sets all bits to zero. Receiver ignores all bits | +| Header Format | 1 bit | 0 = CTI signaling body<br>1 = CTI report body | +| CTI Signature | 1 bit | 0 = Signature is not attached<br>1 = Signature is attached | +| | | | +| Sequence number | 8 bits | Used for detecting dropped messages | +| CTI Session ID | 6 bytes | Globally unique network interface ID<br>0x00 0x00 0x00 0x00 0x00 0x00 : null session | + +The version field is set to 1, referring to the current version of CTI TC-plane specification. + +The header format bit indicates the nature of the message body. + +The CTI Signature bit indicates if the signature is attached to the current message. + +The sequence field is incremented by one for each CTI message sent and continuously wraps after a count of 256. + +The CTI Session ID is a globally unique identifier. Typically, it corresponds to MAC address of the O-RU's physical interface for which the bytes traverse that the CTI message describes. If the sender does not have a valid CTI Session ID, the null session is inserted. + +### 5.1.3 CTI Signaling Messages + +The CTI signaling message types and the body content each type contains are listed in Table 5.2. + +**Table 5.2 : CTI Signaling Messages** + +| CTI Signaling Message | Signaling Body Content | +|-------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| CTI-Beacon | The CTI-Beacon is sent from the O-DU to the TN.<br>Shall contain: <ul style="list-style-type: none"> <li>Message Type, Length</li> </ul> | +| CTI-Beacon-Ack | The CTI-Beacon-Ack is sent from the TN to the O-DU.<br>Shall contain: <ul style="list-style-type: none"> <li>Message Type, Length</li> </ul> | +| CTI-Keep-Alive | The CTI-Keep-Alive is sent between the O-DU and the TN.<br>Shall contain <ul style="list-style-type: none"> <li>Message Type, Length</li> </ul> | +| TN Ranging Notification | The TN ranging notification is sent from the TN to the O-DU<br>Shall contain <ul style="list-style-type: none"> <li>Message Type, Length</li> <li>TN Ranging TLVs</li> </ul> | + +#### 5.1.3.1 CTI Signaling Body + +**Table 5.3 : CTI Signaling Body** + +| Information Element | Size | Description | +|---------------------|---------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Message Type | 1 byte | CTI Signaling Message Type<br>0 = CTI-Beacon<br>1 = CTI-Beacon Ack<br>2 = CTI-Keep-Alive<br>3 = TN Ranging Notification (RN)<br>The values of 4 to 255 are reserved | +| Length Field | 2 bytes | Length field from the next byte to the end of the TLV field. | +| Parameter Field | N | Nested TLVs | + +The signaling body is used to send information that is not request information between the CTI server and CTI client. A signaling message shall not span more than one Ethernet frame. + +#### 5.1.3.2 CTI Signaling TLVs + +**Table 5.4 : CTI Signaling TLVs** + +| Type | Length | Value | +|------|--------------|-----------------------------------------------------------------| +| 1 | 4 | TN Ranging Start Time, PTP format, seconds field | +| 2 | 4 | TN Ranging Start Time, PTP format, nanoseconds field | +| 3 | 3 | TN Ranging Maximum Event Duration, in units of 1.024 $\mu$ s | +| 4 | 1 | TN Ranging Maximum Interruption Size, in units of 2.048 $\mu$ s | +| 5 | Variable N+1 | TN Ranging Impacted Sessions | +| 5.1 | 1 | TN Ranging Amount of Session IDs | + +| | | | +|-----|------------|--------------------------------| +| 5.2 | Variable N | TN Ranging List of Session IDs | +|-----|------------|--------------------------------| + +Table 5.4 shows TLVs within their hierarchy. The type expression “x.y.z” would refer to a sub-type value of “z” that is contained within a next higher level TLV with a sub-type of “y” which in turn is contained within a top level TLV of type “x”. The type field and length field are always one byte in size. The value in the length field is the length of the value field. A length of “N” indicates a variable size of the corresponding value field. + +#### 5.1.3.3 Examples of CTI Signaling Messages + +Table 5.5 and Table 5.6 illustrate the structure of some example messages. + +**Table 5.5: Example of CTI-Beacon-Ack Signaling Message** + +| Name | Length (value) | +|--------------------------|------------------------| +| [Header] Version nb | 4 bits | +| [Header] Reserved | 2 bits | +| [Header] Header format | 1 bit (value = 0) | +| [Header] CTI signature | 1 bit | +| | | +| [Header] Sequence number | 1 Byte | +| [Header] CTI session ID | 6 Bytes | +| [Body] Message type | 1 Byte (value = 0x01) | +| [Body] Length field | 2 Bytes (value = 0x00) | + +**Table 5.6: Example of TN Ranging Notification Signaling Message with 2 CTI Session IDs** + +| Name | Length (value) | +|---------------------------------------------|------------------------| +| [Header] Version nb | 4 bits | +| [Header] Reserved | 2 bits | +| [Header] Header format | 1 bit (value = 0) | +| [Header] CTI signature | 1 bit | +| | | +| [Header] Sequence number | 1 Byte | +| [Header] CTI session ID | 6 Bytes | +| [Body] Message type | 1 Byte (value = 0x03) | +| [Body] Length field | 2 Bytes (value = 0x29) | +| [Body] TN ranging start time, s – T | 1 Byte (value = 0x01) | +| [Body] TN ranging start time, s – L | 1 Byte (value = 0x04) | +| [Body] TN ranging start time, s – V | 4 Bytes | +| [Body] TN ranging start time, ns – T | 1 Byte (value = 0x02) | +| [Body] TN ranging start time, ns – L | 1 Byte (value = 0x04) | +| [Body] TN ranging start time, ns – V | 4 Bytes | +| [Body] TN ranging max event duration - T | 1 Byte (value = 0x03) | +| [Body] TN ranging max event duration – L | 1 Byte (value = 0x03) | +| [Body] TN ranging max event duration - V | 3 Bytes | +| [Body] TN ranging max interruption size - T | 1 Byte (value = 0x04) | +| [Body] TN ranging max interruption size – L | 1 Byte (value = 0x01) | +| [Body] TN ranging max interruption size - V | 1 Byte | + +| | | +|------------------------------------------------|-----------------------| +| [Body] TN ranging impacted sessions - T | 1 Byte (value = 0x05) | +| [Body] TN ranging impacted sessions – L | 1 Byte (value = 0x13) | +| [Body] TN ranging amount of session IDs – T | 1 Byte (value = 0x01) | +| [Body] TN ranging amount of session IDs – L | 1 Byte (value = 0x01) | +| [Body] TN ranging amount of session IDs – V | 1 Byte (value = 0x02) | +| [Body] TN ranging list of session lds, nb1 – T | 1 Byte (value = 0x02) | +| [Body] TN ranging list of session lds, nb1 – L | 1 Byte (value = 0x06) | +| [Body] TN ranging list of session lds, nb1 – V | 6 Bytes | +| [Body] TN ranging list of session lds, nb2 – T | 1 Byte (value = 0x02) | +| [Body] TN ranging list of session lds, nb2 – L | 1 Byte (value = 0x06) | +| [Body] TN ranging list of session lds, nb2 – V | 6 Bytes | + +### 5.1.4 CTI Report Body + +**Table 5.7 : CTI Report Body** + +| Information Element | Size | Description | +|------------------------------------------|---------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>CTI Report Message Body (9 bytes)</b> | | | +| CTI Base seconds | 32 bits | Absolute time value directly derived from the 1588v2 timestamp based on the lower four bytes of the PTP "seconds" field and the full value of the PTP "nanoseconds" field. The value typically corresponds to a slot boundary on the O-RU antenna interface. | +| CTI Base nanoseconds | 32 bits | | +| CTI Table Size | 8 bits | Total number of row entries: CTI Type 1 rows + CTI Type 1 Extension rows (if present) + CTI Type 2 Row (if present) | + +| | | | +|---------------------------------------------|---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>CTI Type 1 Row (Repeated, N*6 bytes)</b> | | | +| Flow ID | 8 bits | User-defined Flow ID, valid range 0x00 to 0xEF. This ID is agreed upon by TN and O-DU. | +| End Time Offset | 16 bits<br>unsigned | Offset in units of 2 <sup>10</sup> nanoseconds (1,024 μs) that is added to the Base nanoseconds value to obtain when the last bit of the requested bytes will egress the R3 reference point of the O-RU. | +| Bytes Requested | 24 bits | Bytes per Flow ID per time interval that cross the O-RU Network (Ethernet) Interface | + +| | | | +|-----------------------------------------------------------------------------------|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>CTI Type 1 Extension Row (6 bytes, optionally included after a CTI Report)</b> | | | +| Extension Field | 8 bits | Value = 0xFF | +| Start Time Offset | 16 bits<br>unsigned | Offset in units of 2 <sup>10</sup> nanoseconds (1,024 μs) that is added to the Base nanoseconds value to obtain when the subinterval described by the pattern ID begins on the network interface of the O-RU (R3 reference point). | +| CTI Pattern ID | 24 bits | Pattern ID within a subinterval that begins with start time and ends with the End Time Offset as indicated in the previous CTI Report. The subinterval typically corresponds to a 5G slot | + +| | | | +|----------------------------------------------------------------------------|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>CTI Type 2 Row (6 bytes, optionally included, once per CTI message)</b> | | | +| Extension Field | 8 bits | Value = 0xFE | +| CTI Message Generation Time | 16 bits<br>signed | Offset in units of 2 <sup>10</sup> nanoseconds (1,024 μs) that is added to the Base nanoseconds value to obtain when the message is generated. This can be useful for TN to calculate message jitter. The upper most bit is signed. A "0" value represents a positive number while a "1" value represents a negative number. This creates a range of +/- 33,5 ms | +| Reserved | 24 bits | Reserved field | + +A reporting message shall not span more than one Ethernet frame. + +#### 5.1.4.1 CTI Time Format + +The CTI message uses an abbreviated form of the ten-byte PTP timestamp format in its message header. The lower four bytes are used to count nanoseconds and the upper four bytes are used to count seconds. CTI then uses a two-byte offset in each row. This is shown in Figure 5.5. The two-byte offset has been chosen to have a minimum resolution of 1.024 $\mu$ s. With a 16-bit offset field, the maximum resolution is 67.1 ms. The offset itself is in a power-of-two format that is compatible with the nanosecond counter in the PTP timestamp so that the two values can be efficiently added together. + +![Figure 5.5: CTI Offset per Row. The diagram shows two bit fields. The top field is 31 bits long, with bit positions 31, 23, 15, 7, and 0 marked. Above the field, maximum values are indicated: <1 s, 16,78 ms, 65,54 μs, 256 ns, and 1ns. The bottom field is 25 bits long, with bit positions 25, 23, 15, and 10 marked. Above this field, maximum values are indicated: 67,1 ms and 1,024 μs. To the right of the fields, a list of values is provided: LTE subframe = 1 ms; LTE symbol time (with CP) = 71,4 μs; 5G NR slot = 62,5 to 1 000 μs; 5G symbol time (with CP) = 4,46 to 71,35 μs. Below the fields, a note states: 'The value to the right of a bit position is the resolution; the value to the left of a bit position is maximum value.'](dd49aea9f36e0434db7cae93698ff207_img.jpg) + +Figure 5.5: CTI Offset per Row. The diagram shows two bit fields. The top field is 31 bits long, with bit positions 31, 23, 15, 7, and 0 marked. Above the field, maximum values are indicated: <1 s, 16,78 ms, 65,54 μs, 256 ns, and 1ns. The bottom field is 25 bits long, with bit positions 25, 23, 15, and 10 marked. Above this field, maximum values are indicated: 67,1 ms and 1,024 μs. To the right of the fields, a list of values is provided: LTE subframe = 1 ms; LTE symbol time (with CP) = 71,4 μs; 5G NR slot = 62,5 to 1 000 μs; 5G symbol time (with CP) = 4,46 to 71,35 μs. Below the fields, a note states: 'The value to the right of a bit position is the resolution; the value to the left of a bit position is maximum value.' + +**Figure 5.5 : CTI Offset per Row** + +Figure 5.6 shows the relationship between the CTI base timestamp and the various offsets. The start and end time offsets are always positive values, while the message generation offset may be a positive or negative value. If the value of CTI message generation time is negative, it indicates it is before the base time. + +![Figure 5.6: Time offsets within the CTI message. The diagram shows a timeline with three slots: Slot (n-1), Slot (n), and Slot (n+1). A vertical dashed line marks the 'Generation of CTI message for slot(n) by O-DU'. A horizontal double-headed arrow labeled 'CTI message generation time offset' spans from this point to the 'Base time of day for slot(n)'. A vertical dashed line marks the 'Start of UL fronthaul packets for slot(n)'. A horizontal double-headed arrow labeled 'Start time offset = Ta3' spans from the base time to this point. A vertical dashed line marks the 'End of UL fronthaul packets for slot(n)'. A horizontal double-headed arrow labeled 'End time offset' spans from the base time to this point. The timeline ends with 'Time at O-RU R3' and 'Time at O-RU Ra'.](d98cad5d2aebd1e5370d6d848f56fa93_img.jpg) + +Figure 5.6: Time offsets within the CTI message. The diagram shows a timeline with three slots: Slot (n-1), Slot (n), and Slot (n+1). A vertical dashed line marks the 'Generation of CTI message for slot(n) by O-DU'. A horizontal double-headed arrow labeled 'CTI message generation time offset' spans from this point to the 'Base time of day for slot(n)'. A vertical dashed line marks the 'Start of UL fronthaul packets for slot(n)'. A horizontal double-headed arrow labeled 'Start time offset = Ta3' spans from the base time to this point. A vertical dashed line marks the 'End of UL fronthaul packets for slot(n)'. A horizontal double-headed arrow labeled 'End time offset' spans from the base time to this point. The timeline ends with 'Time at O-RU R3' and 'Time at O-RU Ra'. + +**Figure 5.6 : Time offsets within the CTI message** + +#### 5.1.4.2 CTI Type 1 Row + +Each Type 1 row represents a report entry and is used to request some number of bytes at some future time on a specific CTI flow. Each CTI row entry includes a CTI Flow ID, the end time offset and the number of bytes requested. The CTI Flow ID is defined via OSS and is common between the TN and the O-DU. The purpose of CTI Type 1 Row is to convey the Requested Bytes (3 bytes in length) associated with a particular Flow ID and end time. The valid range of the Flow ID is 0x00 to 0xEF. The value 0x00 indicates there is no differentiation between the flows and that the Flow ID does not need to be interpreted by the CTI server. The reserved types range from 0xF0 to 0xFD, allowing the option to use 0xFE to 0xFF to indicate special row extension types. + +A CTI Flow corresponds to a flow of packets that can be identified with a set of unique L2 and/or L3 headers that all traverse the same O-RU network interface and share the same QoS. + +Typically, there is one CTI Flow ID per fronthaul flow, as designated by the eAxC header in the eCPRI message. CTI may report each fronthaul flow individually. Alternatively, CTI may aggregate multiple fronthaul flows that are traversing the same O-RU network interface into one CTI Flow ID. + +The CTI message may also have more than one entry per CTI Flow ID. This allows for a lower frequency of CTI messages to still cover multiple traffic intervals of the flow. + +#### 5.1.4.3 CTI Type 1 Extension Row + +The purpose of CTI Type 1 Extension Row is to convey the start time offset of the considered time interval and the fronthaul traffic pattern descriptor (encoded as the CTI Pattern ID), as defined in Table 5.7. + +The CTI client may include one or multiple Type 1 Extension Rows in a CTI message and shall respect following rules: + +- A Type 1 Extension Row shall be included directly after a CTI Type 1 Row and such Type 1 Extension Row then applies to all previous Type 1 Rows until a previous Type 1 Extension Row or the first Type 1 Row in the message. +- The CTI client shall not include more than one CTI Type 1 Extension Row directly following a given CTI Type 1 Row. +- The CTI client shall not include a CTI Type 1 Extension Row without a CTI Type 1 Row. + +Examples of combinations of CTI Type 1 Rows and CTI Type 1 Extension Rows in a CTI report message are illustrated below: + +| 1 flow with 2 patterns | Flow ID | End time offset | Start time offset | Pattern ID | Bytes requested | +|------------------------------------|---------|-----------------|-------------------|------------|-----------------| +| Type 1 Row<br>Type 1 Extension row | 1 | k | j | A | X | +| Type 1 Row<br>Type 1 Extension row | 1 | k | j | B | Y | + +| 2 flows with single pattern per flow | Flow ID | End time offset | Start time offset | Pattern ID | Bytes requested | +|--------------------------------------------------|---------|-----------------|-------------------|------------|-----------------| +| Type 1 Row<br>Type 1 Row<br>Type 1 Extension row | 1<br>2 | k<br>k | j | A | X<br>Y | + +| 2 flows with 2 patterns per flow | Flow ID | End time offset | Start time offset | Pattern ID | Bytes requested | +|------------------------------------|---------|-----------------|-------------------|------------|-----------------| +| Type 1 Row<br>Type 1 Extension row | 1 | k | j | A | W | +| Type 1 Row<br>Type 1 Extension row | 1 | k | j | B | X | +| Type 1 Row<br>Type 1 Extension row | 2 | k | j | C | Y | +| Type 1 Row<br>Type 1 Extension row | 2 | k | j | D | Z | + +| 1 flow with single pattern, multiple intervals | Flow ID | End time offset | Start time offset | Pattern ID | Bytes requested | +|------------------------------------------------|---------|-----------------|-------------------|------------|-----------------| +| Type 1 Row<br>Type 1 Extension row | 1 | k | j | A | X | +| Type 1 Row<br>Type 1 Extension row | 1 | l | k | A | Y | + +1 +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 +16 +17 +18 +19 +20 +21 +22 +23 +24 +25 +26 +27 +28 +29 +30 +31 +32 +33 +34 +35 +36 +37 +38 +39 + +The Extension Field uses a reserved value of 0xFF to indicate that the current row is an extension row for fronthaul. + +The start time of the CTI Type 1 Extension Row and the End time offset of its corresponding (preceding) CTI Type 1 Row(s) together define an interval (e.g., a mobile slot) whose traffic pattern may be described by the CTI Pattern ID field in the CTI Type 1 Extension Row. See Figure 5.6 for the time offsets. + +The use of the Pattern ID is optional: the Type 1 Extension Row may also be used to only communicate the start time of the time interval without details of the traffic pattern, by using CTI Pattern ID value of 0. + +#### 5.1.4.4 CTI Type 2 Row + +The purpose of CTI Type 2 Row is to allow the measurement of message latency by the TN. The Type 2 Row is optional and if used it shall only be included at the end of the CTI report body, with or without the presence of a CTI Type 1 Row. The CTI client shall not include more than one CTI Type 2 Row per CTI message. + +The Extension Field uses a reserved value of 0xFE to indicate that the current row is a special row. + +The CTI message generation time (see Figure 5.6) is useful to calculate the transmission time of a CTI message and the jitter between the CTI messages. The value is the offset from the CTI base nanoseconds value. + +### 5.1.5 CTI Signature + +The CTI Signature is an optional feature that prevents a CTI message from a malicious source (which might have cloned an IP source address) from being accepted. A CTI message is sent in the clear followed by a CTI Signature. This permits implementations to use the contents of the CTI message without having to decrypt or decode each packet. For example, a system could be built in which the CTI message is received in real time but the CTI Signature is sampled on a random basis and not verified in real time. + +*The full details of the CTI Signature are for a future version of this specification.* + +## 5.2 Operation + +### 5.2.1 CTI Discovery & Configuration + +For each CTI Session ID, several associations are required for proper CTI operation: + +- the TN shall have the association of CTI Session ID (pertaining to an O-RU interface) with the corresponding TU interface +- the TN shall have the association of CTI Session ID with the corresponding CTI client (in O-DU) to which it has to communicate CTI-Beacon-Ack, CTI-Keep-Alive and possibly PON ranging notifications. +- the O-DU shall have the association of CTI Session ID with the corresponding CTI server (in TN) to communicate CTI reports and keepalives to. + +Before the O-RU is installed, it is assumed that the OSS does not know which O-RU is associated with which transmission system (TU, TN). Further, since fronthaul takes a lot of bandwidth on the transmission system, it has to be a provisioned service. This section describes at least two ways that the two systems can learn of each other. + +In both of these procedures, the transport system comes up and is initialized. This then provides connectivity for the mobile system to come up and initialize. This implies that there is a least enough bandwidth on the transport system to provide M-plane support between the O-RU and O-DU. + +The next step is to then associate the mobile system with the transport system. The assumption is that the O-RU is an arbitrary unit that gets installed at an O-RU location. + +#### 5.2.1.1 Manual Discovery + +![Figure 5.7: CTI Manual Discovery diagram. The diagram shows the interaction between Mobile OSS, Transport OSS, O-RU, TU, TN, and O-DU. 1. Manual RU-TU pairing: O-RU sends a message to Mobile OSS. 2. CTI Config: Transport OSS sends Initial Config to TN, and Mobile OSS sends Initial Config to O-DU. 3. CTI-Beacon: TN sends a message to O-DU. 3. CTI-Beacon-Ack: O-DU sends a message to TN. 4. CTI-Keep-Alive: TN sends a message to O-DU. 4. CTI-Keep-Alive: O-DU sends a message to TN. 5. CTI-Report: O-DU sends a message to TN. The diagram also shows the N:1 relationship between TU and TN, and the N:N relationship between TN and O-DU.](26ad6db84883dd27f2cc81bf017fb837_img.jpg) + +Figure 5.7: CTI Manual Discovery diagram. The diagram shows the interaction between Mobile OSS, Transport OSS, O-RU, TU, TN, and O-DU. 1. Manual RU-TU pairing: O-RU sends a message to Mobile OSS. 2. CTI Config: Transport OSS sends Initial Config to TN, and Mobile OSS sends Initial Config to O-DU. 3. CTI-Beacon: TN sends a message to O-DU. 3. CTI-Beacon-Ack: O-DU sends a message to TN. 4. CTI-Keep-Alive: TN sends a message to O-DU. 4. CTI-Keep-Alive: O-DU sends a message to TN. 5. CTI-Report: O-DU sends a message to TN. The diagram also shows the N:1 relationship between TU and TN, and the N:N relationship between TN and O-DU. + +**Figure 5.7 : CTI Manual Discovery** + +Proposed procedure: + +1. The installation technician interfaces with the OSS, either verbally or through a user interface, and enters identity information for the O-RU interface and TU interface +2. The TN OSS knows or is able to determine the association of the TU with the TN. The OSS system(s) initializes the O-DU and TN. The TN has the association of TU interface with O-RU interface (its CTI Session ID). The O-DU has the association of O-RU with TN (its CTI server) +3. CTI messaging can commence between the O-DU and TN + +The advantage of this approach is that it is very simple and, depending on how the cross provisioning is performed, does not necessarily require a coupling between the two OSS systems. The disadvantage is that the system is not automated. + +#### 5.2.1.2 Automatic Discovery using the OSS (Informative) + +This section is superseded by section 6.2 of O-RAN CTI-TMP [4]. + +### 5.2.2 Operations + +The CTI server and client shall operate as described in Figure 5.8. + +![Figure 5.8: CTI Configuration and Operational State Machines. The diagram shows two state machines: CTI Client and CTI Server. The CTI Client starts with 'Mobile System Initialized', checks 'CTI Enabled?'. If 'Yes', it sends 'CTI-Beacon', resets 'CTI_TO' timer, and waits for 'CTI-Beacon-Ack'. If 'No', it loops back. Upon receiving 'CTI-Beacon-Ack', it resets 'CTI_TO', 'CTI_KA', and 'CTI_NOM' timers and enters 'Mobile System CTI Operational' state. In this state, it can send 'CTI-Report' (if 'CTI_TO' expires), 'CTI-Keep-Alive' (if 'CTI_KA' expires), or receive 'CTI-Keep-Alive' (if 'CTI_TO' expires). The CTI Server starts with 'Transport System Initialized', checks 'CTI Enabled?'. If 'Yes', it waits for 'CTI-Beacon', receives it, sends 'CTI-Beacon-Ack', and resets 'CTI_KA' and 'CTI_TO' timers, entering 'Transport System CTI Operational' state. In this state, it can receive 'CTI-Keep-Alive' (if 'CTI_KA' expires), send 'CTI-Keep-Alive' (if 'CTI_KA' expires), forward 'CTI-Report' to the scheduler (if 'CTI_TO' expires), or receive 'CTI-Report' (if 'CTI_TO' expires).](ee8d1fefcdf57f18e2511f68f1a9e75e_img.jpg) + +Figure 5.8: CTI Configuration and Operational State Machines. The diagram shows two state machines: CTI Client and CTI Server. The CTI Client starts with 'Mobile System Initialized', checks 'CTI Enabled?'. If 'Yes', it sends 'CTI-Beacon', resets 'CTI\_TO' timer, and waits for 'CTI-Beacon-Ack'. If 'No', it loops back. Upon receiving 'CTI-Beacon-Ack', it resets 'CTI\_TO', 'CTI\_KA', and 'CTI\_NOM' timers and enters 'Mobile System CTI Operational' state. In this state, it can send 'CTI-Report' (if 'CTI\_TO' expires), 'CTI-Keep-Alive' (if 'CTI\_KA' expires), or receive 'CTI-Keep-Alive' (if 'CTI\_TO' expires). The CTI Server starts with 'Transport System Initialized', checks 'CTI Enabled?'. If 'Yes', it waits for 'CTI-Beacon', receives it, sends 'CTI-Beacon-Ack', and resets 'CTI\_KA' and 'CTI\_TO' timers, entering 'Transport System CTI Operational' state. In this state, it can receive 'CTI-Keep-Alive' (if 'CTI\_KA' expires), send 'CTI-Keep-Alive' (if 'CTI\_KA' expires), forward 'CTI-Report' to the scheduler (if 'CTI\_TO' expires), or receive 'CTI-Report' (if 'CTI\_TO' expires). + +**Figure 5.8 : CTI Configuration and Operational State Machines** + +The following operation is illustrated in Figure 5.8. + +After necessary initial configuration, which is to be covered in the future Transport Management Plane Specification, a CTI interaction between a CTI client and a CTI server starts by including an exchange of CTI-Beacon message from the O-DU to the TN and its acknowledgement back from the TN to the O-DU. After reception of the CTI-Beacon-Ack message, both sides are operational for CTI. + +The CTI client and CTI server then interact according to the following: + +1. The CTI client periodically sends a CTI-Report message to the CTI server with request information. This occurs no more than one CTI-Report per CTI Nominal message exchange time interval (CTI\_NOM). If there is no internal request information, the CTI client shall not send a CTI-Report message to request bytes. +The CTI client shall generate a CTI-Keep-Alive message at least once within the CTI Time Keep-Alive (CTI\_KA). +2. The TN captures and processes CTI messages. +The CTI server shall generate a CTI-Keep-Alive message at least once within the CTI Time Keep-Alive (CTI\_KA). +3. If the TN does not receive a CTI message (CTI-Report or CTI-Keep-Alive) within the CTI Time Out (CTI\_TO), it shall suspend its CTI operation and return to the CTI configuration state. +4. If the O-DU does not receive a CTI-Keep-Alive message within the CTI Time Out (CTI\_TO), it shall suspend its CTI operation and return to the CTI configuration state. + +The contents of the CTI-Report message are generated by the CTI client, which takes its inputs from the O-DU's uplink scheduling decisions and from other operating entities within the O-DU. The CTI client gathers the uplink grant information from the RAN uplink scheduler over an interval described by the CTI Nominal message exchange time interval (CTI\_NOM). This time is configured to be an integral number of mobile slot times. The choice of CTI\_NOM + +shall follow the rules described in section 4.3.3.2. The CTI client should modify the local grant information from the O-DU RAN scheduler to make it represent future bytes to be transmitted over the Ethernet interface with sufficient margin for allowing for prediction uncertainties on the actual generated uplink fronthaul traffic. + +## 5.3 Interface to OSS + +### 5.3.1 Timers + +**Table 5.8 : CTI Timers** + +| Name | OSS<br>to TN | OSS<br>to<br>O-DU | Min | Max | Description | +|--------------------------------------------|--------------|-------------------|---------|------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| CTI Nominal message exchange time interval | x | x | 0,25 ms | 5 ms | This value, abbreviated as CTI_NOM, is the minimum average interval that a CTI-Report message is sent from the CTI client to the CTI server. CTI-Report messages may be sent less often. Because of queuing in the system, this value has to be interpreted as a rate and not as a spacing between packets. Typical values could be 1–2 ms for LTE, or lower for 5G. | +| CTI Time Keep-Alive | x | x | | 3 s | This value, abbreviated as CTI_KA, is the maximum time interval between consecutive CTI-Keep-Alive messages between the CTI client and the CTI server. | +| CTI Time Out | x | x | | 10 s | This value, abbreviated as CTI_TO, is the timeout value that a CTI Keep-Alive message needs to be received by the CTI client (O-DU) or the CTI server (transport system) before that respective system suspends CTI operations and returns to its CTI configuration state. | + +CTI\_TO shall be greater than CTI\_KA, for example $CTI\_TO = N * CTI\_KA$ with N being an integer greater than 1, to allow for the loss of one or several keepalives. + +### 5.3.2 Summary of Objects (Informative) + +Several parameters have to be configured in the O-DU and the TN by their respective management systems for the connectivity of CTI messages and the operation of CTI. The reader is referred to O-RAN CTI TMP [4] for a full list of parameters and the accompanying YANG models. + +## 5.4 Examples of the CTI Pattern Descriptor for Fronthaul + +A high-speed transport system such as a 10 Gbps PON system can have the ability to schedule bandwidth with the granularity of an 5G OFDMA symbol time which is on the order of 4.5μs to 71μs. However, sending CTI messages at this rate would result in too high a message rate. Further, describing bytes for every single symbol would result in excessively long CTI messages. In order to balance message frequency and length, a compression scheme based on 5G TDD/FDD patterns is allowed. + +The CTI pattern object model allows one entry in a CTI message to describe multiple transmissions over the network interface that follow a specific pattern. The intended use is to describe the bytes per symbol for each symbol or group of symbols within a mobile slot. The pattern of bytes per symbol within a mobile slot depends upon the 5G use of TDD or FDD. + +The total byte count for a pattern is always contained in the CTI table entry. If a non-zero pattern ID is used in the CTI reporting, there are two ways to interpret the CTI pattern parameters at the CTI server: + +Option 1) The CTI client is configured so that the total byte count is equal to the sum of the bytes per event within the pattern. This implies that for each different load in a mobile slot (different total byte count), a different pattern ID is needed. This can be used when the reporting may be coarse and not too many pattern IDs are needed. It is also possible to use a mix of explicit byte values for some symbols and a residual byte count (indicated by a reserved special value) for the other symbols. The absolute bytes for the residual symbols are deduced based on the CTI total byte count and the per-event explicit byte counts (see example 3 below). + +Option 2) If option 1 has a scalability issue, the alternative is to normalize the amount of bytes in each symbol so that the sum of all symbols is always the same value independently of the total reported byte count. The CTI server can then deduce the actual amount of bytes per symbol by using a multiplier (the reported total byte count divided by the normalized sum). This allows to re-use the same pattern ID for the same relative distribution of bytes across the symbols, by adding an extra calculation step at the CTI server. + +The choice between option 1) and option 2) is reflected by a dedicated configuration parameter per CTI session ID, so that the CTI client knows how to generate the values and the CTI server knows how to interpret the values. + +### Examples + +Example 1: FDD pattern of 1 ms slot (n), 14 symbols, 1,000 bytes per symbol and same pattern but with 2,000 bytes per symbol in another 1 ms slot (m) + +Option 1: Absolute event bytes + +For slot n: + +- Pattern ID = 1 +- Pattern duration = 8 (because $8 \times 125 \mu\text{s} = 1 \text{ ms}$ ) +- Number of events per pattern = 14 (because each symbol is described) +- Event description + - Event multiplier = 14 (because each event is the same within the pattern) + - Bytes per event = 1,000 bytes (because there are 1,000 bytes per symbol) +- The sum over the symbols corresponds to the CTI total byte count of 14,000 bytes. This is the total number of bytes transmitted during the entire slot time. + +For slot m: + +- Pattern ID = 2 +- Pattern duration = 8 (because $8 \times 125 \mu\text{s} = 1 \text{ ms}$ ) +- Number of events per pattern = 14 (because each symbol is described) +- Event description + - Event multiplier = 14 (because each event is the same within the pattern) + - Bytes per event = 2,000 bytes (because there are 2,000 bytes per symbol) +- The sum over the symbols corresponds to the CTI total byte count of 28,000 bytes. This is the total number of bytes transmitted during the entire slot time. + +Option 2: Normalized event bytes + +For slot n: + +- Pattern ID = 1 +- Pattern duration = 8 (because $8 \times 125 \mu\text{s} = 1 \text{ ms}$ ) +- Number of events per pattern = 14 (because each symbol is described) +- Event description + - Event multiplier = 14 (because each event is the same within the pattern) + - Bytes per event = 100 bytes (normalized sum / 14) +- The normalized sum (arbitrary choice) is 1,400 bytes. The CTI total byte count is 14,000 bytes. The per-symbol multiplying factor to be used at the CTI server is 10. + +For slot m: + +- Same Pattern ID = 1 +- The normalized sum is 1,400 bytes. The CTI total byte count is 28,000 bytes. The per-symbol multiplying factor to be used at the CTI server is 20. + +Example 2 (Option 1): TDD receive pattern of 500 $\mu\text{s}$ slot; 14 symbols; 1,000 bytes on symbols 0, 1, 2, 10, 11, 12; 0 bytes otherwise + +- Pattern ID = 2 +- Pattern duration = 4 (because $4 \times 125 \text{ } \mu\text{s} = 500 \text{ } \mu\text{s}$ ) +- Number of events per pattern = 14 (because each symbol is described) +- Event description + - Event multiplier = 3 for symbols 0–2 + - Bytes per event = 1,000 bytes for each of the first three symbols + - Event multiplier = 7 for symbols 3–9 + - Bytes per event = 0 bytes + - Event multiplier = 3 for symbols 10–12 + - Bytes per event = 1,000 bytes for each of these three symbols + - The entry for symbol 13 is optional because the value is 0 bytes. +- The CTI byte count is 6,000 bytes. + +Example 3 (Option 1): A 5G 500 $\mu\text{s}$ slot; 200 bytes total of signaling information on symbols 0 and 1; variable but evenly distributed payload on symbols 4 to 7. An event is two symbols. The CTI byte count is 1,000 bytes. + +- Pattern ID = 3 +- Pattern duration = 4 (because $4 \times 125 \text{ } \mu\text{s} = 500 \text{ } \mu\text{s}$ ) +- Number of events per pattern = 7 (because each event is described as a pair of symbols) +- Event description + - Event multiplier = 1 for symbols 0 and 1 + - Bytes per event = 200 bytes total for the first two symbols + - Event multiplier = 1 for symbols 2 and 3 + - Bytes per event = 0 bytes + - Event multiplier = 2 for symbols 4–7 + - Bytes per event = residual average (0xFFFF) + - The entry for symbols 8–13 is optional because the value is 0 bytes per symbol. +- Residual average = $(1,000 - 200) / 2 = 400$ bytes per event + - The total byte count is 1,000 bytes. There were 7 events. Each event is two symbols. The first event was explicitly described as 200 bytes. The next event was explicitly described as 0 bytes. The next two events were declared as residual averages. The last four events were not explicitly described, so they are implicitly considered to be 0 bytes per event. + - Because each event is two symbols, the byte count for symbols 4–7 is 200 bytes per symbol. + +## 5.5 Other O-DU Functional requirements + +### 5.5.1 Reporting scope + +The O-DU shall be able to generate uplink bandwidth reports per O-RU, aggregated over all corresponding RAN schedulers for that O-RU. + +The O-DU shall be able to generate uplink bandwidth reports per O-RU interface, aggregated over all corresponding RAN schedulers for that O-RU interface. + +The CTI protocol additionally allows to generate uplink bandwidth reports per fronthaul Flow (Layer 2 / Layer 3 mapping). + +### 5.5.2 Reporting accuracy + +The reported bandwidth shall be at least equal to the actual upstream U-plane traffic generated by the O-RU (no underestimation). + +1 The accuracy of reported time references (Base + Offset) shall be better than $10\mu\text{s}$ ( $-5\mu\text{s}/+5\mu\text{s}$ ). + +###### 2 5.5.3 O-DU CTI performance + +3 The O-DU shall be characterized according to a CTI message rate category based on its supported CTI\_MIN (as defined +4 in section 4.3.3). When an equipment supports a category, all lower numbered categories shall also be supported. + +5 The O-DU shall be characterized according to a value of CTI message timing performance (as defined in section 6.2). +6 These parameters shall be exposed to the OSS for configuration and management. + +7 + +# 6 Time alignment between O-DU and Transport + +## 6.1 Timing architecture options + +The Fronthaul O-DU is scheduling in the future. The TN has to follow this by granting allocations aligned in time. This requires the timing of both systems to be time synchronized to a common reference for the grants to line up. There are three options to achieve this; + +- Using GNSS: Both the O-DU and the TN are independently synchronized using a GNSS source. There is no synchronization interaction needed between the O-DU and the TN. +- Using IEEE PTPv2 (1588-2008): Both the O-DU and the TN have access to a common GM clock by using PTPv2. The PTP packets are either independently received by O-DU and TN, or the PTP packets are distributed to the TNs via O-DUs (e.g. when the GM resides in the O-DU). +- Mix of both: The O-DU uses either GNSS or PTP, while the TN independently uses the other method. + +Note that the synchronization of the O-RU itself is not influenced by CTI and is out of scope of the CTI specification (see O-RAN CUS [2] instead). + +## 6.2 Resource allocation alignment + +With CTI, the TN scheduler aligns its granting decisions on reporting by RAN schedulers, in order to follow traffic variations (per slot or per group of slots) of O-RUs. The better the time alignment precision of the TN scheduler to the uplink fronthaul traffic from the O-RUs, the lower the need for buffering uplink packets and hence the lower the upstream latency. + +The precision of alignment depends on two factors, as shown in Figure 6.1; + +Firstly, the arrival time of the CTI reporting message at the TN. The TN will need some processing time once the message is received before it can apply the updates of bandwidth scheduling to its TUs. This can be expressed as a minimal spacing (called “TN CTI message timing performance”) needed between the arrival time of the CTI message and the start boundary at $R_a$ of the mobile slot $N$ being reported in the message. A given TN equipment is characterized by a value of CTI message timing performance. + +The arrival time depends on the O-DU generation time, which depends on the necessary processing time after the RAN scheduler decisions were made for the corresponding slot. This can be expressed as the “O-DU CTI message timing performance”, the minimal spacing guaranteed by the O-DU between the generation time of the CTI message and the start boundary at $R_a$ of the mobile slot $N$ being reported in the message. The O-DU shall be characterized by a value of CTI message timing performance. + +The arrival time also depends on the transmission latency of the CTI message itself (in case of intermediate nodes between O-DU and TN). + +![Figure 6.1: Timing of CTI message generation by O-DU and reception at TN, limits for TN being able to apply bandwidth updates for the reported mobile slot. The diagram shows two horizontal timelines: O-DU (top) and TN (bottom). O-DU timeline: 'RAN scheduler decisions for slot(N)' is a vertical line. 'CTI messages for slot(N)' are generated between 'earliest' and 'latest' points. 'Min CTI processing in O-DU' and 'Max CTI processing in O-DU' are horizontal bars. 'Min transmission latency of CTI messages from O-DU to TN' and 'Max transmission latency of CTI messages from O-DU to TN' are diagonal arrows. TN timeline: 'Min CTI processing in TN' and 'Max CTI processing in TN' are horizontal bars. 'earliest' and 'Latest limit' are vertical lines. 'TN ready to apply scheduling updates for slot(N)' is a vertical line. A bracket at the bottom indicates 't0(N) mobile slot (N) @ Ra'.](e3eb5a2f7f3b19034e8aa0d7ec65f29d_img.jpg) + +Figure 6.1: Timing of CTI message generation by O-DU and reception at TN, limits for TN being able to apply bandwidth updates for the reported mobile slot. The diagram shows two horizontal timelines: O-DU (top) and TN (bottom). O-DU timeline: 'RAN scheduler decisions for slot(N)' is a vertical line. 'CTI messages for slot(N)' are generated between 'earliest' and 'latest' points. 'Min CTI processing in O-DU' and 'Max CTI processing in O-DU' are horizontal bars. 'Min transmission latency of CTI messages from O-DU to TN' and 'Max transmission latency of CTI messages from O-DU to TN' are diagonal arrows. TN timeline: 'Min CTI processing in TN' and 'Max CTI processing in TN' are horizontal bars. 'earliest' and 'Latest limit' are vertical lines. 'TN ready to apply scheduling updates for slot(N)' is a vertical line. A bracket at the bottom indicates 't0(N) mobile slot (N) @ Ra'. + +**Figure 6.1 : Timing of CTI message generation by O-DU and reception at TN, limits for TN being able to apply bandwidth updates for the reported mobile slot.** + +If the O-DU CTI message timing performance after subtraction with the maximal CTI transport latency still respects the TN CTI message timing performance, the TN can update the bandwidth for the mobile slot N on time. Note that as long as this condition is met, the jitter on arrival time of the CTI message will have no effect on the bandwidth updates and on the resulting fronthaul uplink latency. + +If the CTI messages arrive early, they have to be buffered in the TN until they need to be processed for their associated mobile slot (N). The earliest arrival time is just after the O-DU has made scheduling decisions for mobile slot (N), which is in the order of several mobile slot durations before the start of mobile slot (N). + +If the CTI messages arrive too late at the TN, the TN will only be able to apply the update for slot N in the next (or one of the next) bandwidth update opportunities by the TN, leading to buffering of the traffic of slot N at the TU, and hence an increase of latency. That latency depends on the granularity of TN to apply bandwidth updates per TU, and the previous bandwidth setting of the TN and buffer status of the TU. + +Secondly, assuming the CTI reporting message does arrive on time at TN, perfect alignment will not be possible due to sources of uncertainty that cannot be influenced or compensated by the O-DU: + +- Time granularity of TN to send bandwidth allocations. +- Variation on $Ta3\_max$ per O-RU (based on its category), typically $20\mu s$ (see table B-5 in O-RAN CUS [2]) +- Possible mix of different O-RU categories on the shared distribution networks of the same TN. + +Note that the difference in propagation distance between different TUs is compensated by time equalization of the TUs by the TN. The actual latency (buffering + propagation) of each TU is brought to the same level, with the furthest TU having the longest propagation and shortest buffering, and the shortest TU having the shortest propagation and the longest buffering. In other words, the time equalization does not introduce an extra delay penalty, but it brings the propagation delay of all TUs to the level of the furthest TU. + +![Figure 6.2: Time alignment of O-DU scheduler decisions, CTI message generation, CTI message reception, TN scheduler updates, uplink traffic at O-RU R3 reference point. Example for two TUs at different distance from the TN.](5f72bd3c816b7a23c9c86ce70ec2a4bf_img.jpg) + +The diagram illustrates the timing relationships between various components in the O-RAN architecture for a specific time slot $N$ . The components shown are O-DU, TN, TU 1, TU 2, O-RU 1, and O-RU 2. + +- O-DU:** Shows "RAN scheduler decisions for slot(N)" and "CTI processing in O-DU". A blue arrow indicates "CTI messages for slot(N)" being sent to the TN. +- TN:** Shows "CTI processing in TN" and "TN ready to apply scheduling updates for slot(N)". A green arrow indicates the "TN CTI message timing category: min time needed before $t_0(N)$ ". +- TU 1 and TU 2:** Show "BW allocations for slot(N)" and "processing in TU + timing of allocations". Red arrows indicate the flow of allocations from the TN to the TUs. +- O-RU 1 and O-RU 2:** Show "fronthaul Traffic slot(N)" and "fronthaul Traffic slot(N)". Blue arrows indicate the flow of traffic from the TUs to the O-RUs. + +Key timing parameters and equations shown in the diagram: + +- $t'_{0, O-RU1}(N) = t_0(N) + Ta_{3O-RU1}$ +- $t'_{0, O-RU2}(N) = t_0(N) + Ta_{3O-RU2}$ +- $t_0(N)$ is the mobile slot (N). + +Figure 6.2: Time alignment of O-DU scheduler decisions, CTI message generation, CTI message reception, TN scheduler updates, uplink traffic at O-RU R3 reference point. Example for two TUs at different distance from the TN. + +**Figure 6.2 : Time alignment of O-DU scheduler decisions, CTI message generation, CTI message reception, TN scheduler updates, uplink traffic at O-RU R3 reference point. Example for two TUs at different distance from the TN.** + +# 7 Conclusion + +## 7.1 Summary + +This document specifies the TC-plane of CTI. TC-plane messages between O-DU and TN allow for the initialisation and operation of a CTI session, and for the exchange of future load requirements so that the TN scheduler can schedule the transport resource pro-actively, reducing the upstream latency of the fronthaul packets compared to a reactive TN scheduling system. + +The document includes (Chapter 4) a description of the context (topologies of interconnecting O-RUs to O-DUs via TNs aggregating multiple TUs on shared distribution networks), (Chapter 5) the required functions on the O-DU for supporting CTI exchange with TNs, the role of the parameters needed for CTI, the message types and formats, the protocol operation, the list of parameters, ways for associating the O-RU interface with corresponding TN managed entity, and (Chapter 6) the time alignment aspects between O-DU scheduler and TN scheduler. + +## 7.2 Open issue list + +- 1 (section 4.1.2) Impact of MAC address as CTI Session ID for load balancing (single flow over multiple O-RU network interfaces) +- 2 (sections 4.3.1.1, 5.1.4.2, 5.5.1) Analysis if and how the flow ID (L2/L3 classifier) could be used to differentiate the CoS of U-plane traffic, and whether this could reflect the CoS of user-generated or user-consumed application data. +- 3 (section 5.1.5) Optionality and details of CTI Signature +- 4 In case of congestion in the transport network, analysis of a feedback mechanism and of the use of priorities between O-RUs + + + +### A.1.1 Dynamic Bandwidth Allocation (DBA) + +Fundamentally, the OLT is the master and tells each ONU when to send traffic (and when to remain silent) by sending grants telling it when to begin and end transmission. This is the responsibility of the DBA algorithm. To be more precise, it is possible to give multiple grants per ONU; + +- In ITU-T compliant PONs, grants are scheduled per Transmission Container (T-CONT, one or multiple T-CONTs per ONU UNI). Each T-CONT can correspond to a different traffic class or to an ONU UNI. Grants are sent in BW maps (1 map every 125 $\mu$ s). +- In IEEE compliant PONs, grants are scheduled per Logical Link ID (LLID, one (typical) or multiple LLIDs per ONU). Typically the ONU does the internal scheduling between traffic classes into a single grant. Grants are sent in special GATE messages (one message per ONU, up to 4 grants per message). + +DBA ensures that data bursts from different ONUs are nicely interleaved without any collision at the OLT receiver. The allocation of bandwidth per T-CONT / LLID and the level of interleaving between the ONUs is chosen by the DBA. + +![Figure A.2: DBA on Passive Optical Networks (ITU-T PON). The diagram illustrates the DBA process between an OLT and two ONUs (ONU 1 and ONU 2). It shows the timing of U/S frames (125μs) and the flow of status reports and data. The OLT sends 'broadcasted Bwmaps' to both ONUs. ONU 1 sends a 'Status report + Data' to the OLT. ONU 2 sends a 'Status report + Data' to the OLT. The OLT then sends an 'Updated broadcasted Bwmaps' to both ONUs. The diagram is divided into two sections: 'DBA decision per T-CONT' and 'DBA updated decision per T-CONT'.](5eecb26a549cf4b310c939c8e2966d15_img.jpg) + +Figure A.2: DBA on Passive Optical Networks (ITU-T PON). The diagram illustrates the DBA process between an OLT and two ONUs (ONU 1 and ONU 2). It shows the timing of U/S frames (125μs) and the flow of status reports and data. The OLT sends 'broadcasted Bwmaps' to both ONUs. ONU 1 sends a 'Status report + Data' to the OLT. ONU 2 sends a 'Status report + Data' to the OLT. The OLT then sends an 'Updated broadcasted Bwmaps' to both ONUs. The diagram is divided into two sections: 'DBA decision per T-CONT' and 'DBA updated decision per T-CONT'. + +**Figure A.2 : DBA on Passive Optical Networks (ITU-T PON)** + +The choice of allocation of bursts to the TCONTs / LLIDs can either be fixed by preconfiguration (Fixed Bandwidth Allocation, allocations are always granted and don't change over time) or dynamic (Dynamic Bandwidth Allocation, the system reacts to measured parameters and adapts the allocations while staying within bounds set by preconfiguration). + +For DBA there are traditionally two types of ways to react; either based on monitoring of the received traffic versus allocated bandwidth, or based on status reports sent by the ONU informing the OLT about the buffer filling levels. Both methods are reactive in the sense that they use snapshots from the (recent) past. + +### A.1.2 DBA Latency Analysis + +The upstream transmission latency and jitter on a T(W)DM PON depends on several factors; + +a) The actual fiber length + +All ONUs are equalized in time to the furthest ONU. As most PON technologies reach out to 20km (some to 40km), the one-way delay due to fiber propagation alone can reach 100 $\mu$ s (200 $\mu$ s) for such distances. Obviously the latency requirement can limit the maximal distance for the deployment. + +b) Buffering in the ONU + +Whenever Ethernet frames have to wait before being transmitted in a PON burst, they need to be buffered and they will experience buffer latency. The waiting time in the buffer depends on two factors, both being controlled by DBA; + +The amount of bandwidth allocated to the T-CONT / LLID + +- As mentioned above, the DBA estimates how much bandwidth to allocate for each T-CONT / LLID. This is either fixed or a dynamic update. If the allocated bandwidth is below the required bandwidth, the ONU buffers will gradually fill up. The filling level depends on the duration and amplitude of this mismatch. Low buffer latency requires fast and accurate DBA updates, but as DBA is a dynamic system influenced by all ONUs, and which + +also possibly interacts with other dynamics like TCP congestion control, it is difficult to predict the latency for a given situation. + +The inter-burst gap for the T-CONT / LLID + +- Once the amount of bandwidth allocated to each T-CONT / LLID is chosen by the DBA, it is delivered in a bursty fashion. The burstiness is also controlled by the DBA. It can be a regular repetition of equal sized bursts at a given rate, or an irregular sequence of bursts. Even when the allocated bandwidth corresponds to the actual demand, Ethernet frames arriving after the end of a burst have to wait for the next burst before they can be sent, thereby experiencing delay up to the gap between the bursts. + +For a given average throughput, it is possible to achieve lower latency by decreasing the burst size while increasing the burst rate, thereby decreasing the inter-burst gap. However this comes at the expense of higher overheads on the PON as each upstream burst “consumes” a fixed amount of non-information bytes (so-called physical layer overhead). Hence a trade-off between efficiency and latency. + +c) Forwarding latency in the switching stages of the OLT and ONU + +As the ONU and OLT act as aggregation points (combination of multiple UNIs in the ONU to a single PON interface, combination of multiple ODNs to fewer network uplinks in the OLT), they include internal switching stages, which each can add some forwarding latency to the Ethernet frames. + +d) Fragmentation and serialization delay + +When fragmentation is supported over the PON, large frames can be split over multiple bursts. Such frames will experience fragmentation delay (waiting up to the burst transmitting the last fragment) and re-assembly processing delay in the OLT. + +Serialization delay occurs when frames are egressing a node or internal node module. It depends on the frame size and the line rate of the interface. However, for the rates considered relevant for LLS fronthaul (10 Gbit/s and above) such delay will be small compared to the other causes of delay. + +### A.1.3 Cooperative Dynamic Bandwidth Allocation (CO-DBA) + +#### A.1.3.1 Rationale for CO DBA + +As noted above, bandwidth is traditionally allocated either in a fixed way or in a reactive dynamic way. + +When applying a fixed guaranteed bandwidth to low-latency traffic, there is no reaction time delay, leading to low latency. The downside however is that such bandwidth has to be dimensioned to the peak rates, and unused portions of this bandwidth cannot be reallocated to other nodes or to other services. + +On the other hand, reactive DBA takes into consideration the dynamic upstream traffic and configured traffic contracts. The benefit to adapt to the actual demands is to allow for statistical multiplexing of many sources (ONUs). The disadvantage is now that upstream data will at times be buffered in the ONU until the completion of bandwidth allocation, leading to higher latency. + +With Cooperative DBA, however, the system becomes pro-active. There is a dynamic in-advance signaling from the O-DU to the OLT to allow the PON system to adapt its dynamic bandwidth allocation to the expected upstream traffic load and timing, thereby limiting latency, while still allowing to apply statistical multiplexing. In other words, the goal of Cooperative DBA is to allow for a better balance on the PON between packet transport latency and bandwidth efficiency than either with fixed bandwidth allocation to peak values, or with traditional reactive DBA-based bandwidth allocation. + +The figure below shows CO DBA in action for two O-RUs, updating the allocated bandwidth per O-RU every mobile slot/TTI. The resulting upstream latency T34 consists of the internal latencies in ONU and OLT, and the DBA-controlled transport of the fronthaul packets in PON bursts. + +![Figure A.3: LLS fronthaul over PON. The diagram illustrates the timing and data flow in a PON system. On the left, a block diagram shows the O-DU connected to the OLT, which is connected to two ONUs (ONU1, ONU2), each with an O-RU. The main part of the diagram is a timeline starting at t=0. It shows the O-DU RX window, packets, forwarding in OLT, DBA cycle, PON bursts, LLS packets, processing in O-RU Ta3 (for symbol 0), and Air symbols. The timeline is divided into mobile slots n, n+1, and n+2. The O-DU RX window shows the Highest T34 and Lowest T34. The OLT forwarding shows the DBA cycle. The PON bursts show the LLS packets and Air symbols. The O-RU processing shows the LLS packets and Air symbols. The O-RU 1 and O-RU 2 show the LLS packets and Air symbols. The O-RU 1 and O-RU 2 show the LLS packets and Air symbols.](4aa4c948463b75633d5b0066df067041_img.jpg) + +Figure A.3: LLS fronthaul over PON. The diagram illustrates the timing and data flow in a PON system. On the left, a block diagram shows the O-DU connected to the OLT, which is connected to two ONUs (ONU1, ONU2), each with an O-RU. The main part of the diagram is a timeline starting at t=0. It shows the O-DU RX window, packets, forwarding in OLT, DBA cycle, PON bursts, LLS packets, processing in O-RU Ta3 (for symbol 0), and Air symbols. The timeline is divided into mobile slots n, n+1, and n+2. The O-DU RX window shows the Highest T34 and Lowest T34. The OLT forwarding shows the DBA cycle. The PON bursts show the LLS packets and Air symbols. The O-RU processing shows the LLS packets and Air symbols. The O-RU 1 and O-RU 2 show the LLS packets and Air symbols. The O-RU 1 and O-RU 2 show the LLS packets and Air symbols. + +**Figure A.3 : LLS fronthaul over PON** + +CO DBA is recognized as a new DBA type in ITU-T PON standards since ITU-T G.989.3 Amd 2. + +#### A.1.3.2 Using CTI for CO DBA + +An information exchange is achieved with CTI between the mobile scheduler (in the O-DU) and the PON scheduler (CO DBA in the OLT). The O-DU makes allocation decisions and signals corresponding information to the OLT, aggregated at O-RU interface level (sum of all UEs). This allows the OLT to determine upstream bandwidth allocations per O-RU interface in advance. The OLT then applies these bandwidth allocations as close as possible to the arrival time of upstream mobile traffic. This avoids the DBA to spend time to detect the presence of the mobile traffic by means of ONU buffer feedback. This enables low-latency upstream transmission. + +The basic mechanism and functional roles of this information exchange are as follows; + +- O-DU and OLT are connected by CTI interface (messages can use the same physical interface as the data traffic). +- The O-DU determines how much traffic will be required for given time intervals and given services. The associated required maximal upstream latency of this traffic can be configured on the TN. The O-DU communicates such reports in signaling messages to corresponding OLT(s) on which the corresponding O-RUs are connected to a PON via ONUs. The O-DU adds an ID per report to identify the service and its corresponding O-RU interface. +- The O-DU updates this information to follow variations in expected bandwidth of the O-RUs. +- The OLT parses these CTI messages, using the ID to link a report to its corresponding T-CONT. The OLT adapts the corresponding PON bandwidth allocations to these T-CONTs according to the reports in the signaling messages, in a way to meet the required capacity and latency. The CO DBA follows the updates sent by the O-DU. + +![Diagram illustrating the CTI interface for CO DBA. The diagram shows a sequence of components: UEs connected to O-RUs, which are connected to ONU (TU) blocks. These are connected to ODN blocks, which are connected to the OLT (TN). The OLT (TN) is connected to the O-DU via the CTI interface. The OLT (TN) also contains a CTI server. The O-DU contains a CTI client. The CTI server and CTI client are connected via CTI messages. The diagram also shows the uplink transport latency T34 and the radio carrier. The timeline includes Ra, Ta3, R3, and R4.](55c74c4cfffc24d29a81d9247ee037c5_img.jpg) + +Diagram illustrating the CTI interface for CO DBA. The diagram shows a sequence of components: UEs connected to O-RUs, which are connected to ONU (TU) blocks. These are connected to ODN blocks, which are connected to the OLT (TN). The OLT (TN) is connected to the O-DU via the CTI interface. The OLT (TN) also contains a CTI server. The O-DU contains a CTI client. The CTI server and CTI client are connected via CTI messages. The diagram also shows the uplink transport latency T34 and the radio carrier. The timeline includes Ra, Ta3, R3, and R4. + +Figure A.4 : Using CTI for CO DBA + +### A.1.4 PON ranging + +As previously explained, when PON is used for mobile fronthaul the OLT acts as the TN, the ONU acts as the TU. The ranging description in this section is generic. + +A PON is an adaptive system in the sense that it enables any ONU to connect (e.g. at installation) or disconnect (e.g. at powering down) at any point in time without preliminary agreement or control from the OLT. But this requires an autodiscovery and autoconfiguration mechanism of newly connected ONUs (this is called “ranging” in short). Both OLT and ONU sides maintain state machines to manage the mechanisms, to follow whatever status changes of the ONUs. + +Automatically connecting a new ONU requires two steps; first, ONU autodiscovery, and second, ONU ranging in order to equalize its time reference for upstream transmission to the ONU with (potential) furthest distance. The equalization is deducing and configuring an extra delay per ONU so as to achieve time alignment of all ONUs at the OLT receiver. + +In order to detect newly connected ONUs, the OLT needs to give them an opportunity to send their unique identification (Serial Number). This involves exchange of information from ONU to OLT without the OLT knowing when this information will arrive. In order to avoid overlap with existing upstream traffic, the OLT opens a “quiet window” by temporarily suppressing the grants to the in-service ONUs for a given duration. The OLT broadcasts a special grant targeted only to new ONUs, such that they start sending their unique number in the upstream direction (a back-off mechanism is included to take care of multiple new ONUs overlapping), see Figure A.5. + +![Figure A.5: autodiscovery process (e.g. ONU 2). The diagram shows a timeline for OLT, ONU 1, ONU 2, and ONU N. The OLT timeline has a 'Quiet window (eg 2 frames = 250µs)' and 'U/S frames (125µs)'. ONU 1 sends a 'Burst with SN' during the quiet window. ONU 2 sends a 'Burst with SN' during the quiet window. ONU N sends a 'Burst with SN' during the quiet window. The OLT sends 'BW maps for traffic of active ONUs' and 'BW map empty except for new ONUs'.](64a02eb982db722ff96a4adb7792e5bf_img.jpg) + +Figure A.5: autodiscovery process (e.g. ONU 2). The diagram shows a timeline for OLT, ONU 1, ONU 2, and ONU N. The OLT timeline has a 'Quiet window (eg 2 frames = 250µs)' and 'U/S frames (125µs)'. ONU 1 sends a 'Burst with SN' during the quiet window. ONU 2 sends a 'Burst with SN' during the quiet window. ONU N sends a 'Burst with SN' during the quiet window. The OLT sends 'BW maps for traffic of active ONUs' and 'BW map empty except for new ONUs'. + +Figure A.5 : autodiscovery process (e.g. ONU 2) + +Once the unique number of a given new ONU is known, the OLT can open another quiet window silencing all other ONUs except the new ONU. The OLT receiver measures the arrival time of the upstream messages of that ONU in the quiet window, and deduces its necessary time equalization, which is then communicated back by the OLT to the ONU. + +At the end of this process, the ONU becomes operational and can receive normal service grants, and send upstream traffic. + +Note that the duration of the ranging window depends on the maximum differential distance (closest ONU to furthest ONU) to be supported, The amount of windows per step can vary (e.g. a window could be repeated a couple of times for more robustness in case of distant or weak ONUs). The repetition rate of the process can be set by the operator (e.g. every second, but can be much shorter or much larger). + +When using PON for fronthaul traffic, such ranging process of new ONUs will cause upstream transport interruption. There are two ways to deal with this. Either the PON system is able to reduce or avoid the interruption time (possibly with modifications to the ranging process as described here, but that can require more complexity on the PON or a dependence on specific PON technologies) so that there will be no or limited impact on the mobile system. Or the PON system notifies the O-DU about upcoming ranging events, so that the O-DU can take mitigating measures. + +### A.1.5 PON technologies + +CO DBA is recognized by ITU-T as a DBA method. There are multiple PON technology variants, and new ones are under definition by the ITU-T SG15/Q2. + +Technologies offering 10 Gbit/s or more: + +- G.9807 series (XGS-PON) +- G.989 series (NG-PON2) +- G.hsp (on-going work at time of publication of this document) + +There are multiple PON technology variants specified by IEEE offering 10 Gbit/s or more: + +- IEEE 802.3av, IEEE 802.3bk +- IEEE 802.3ca (on-going work at time of publication of this document) + +## A.2 DOCSIS as a Transport Technology + +Data Over Cable Service Interface Specification (DOCSIS) is a telecommunication standard that governs the transmission of high-speed data on a hybrid fiber coaxial (HFC) plant. DOCSIS protocol is developed by CableLabs with many contributing companies. The protocol has been ratified by the ITU-T as international standards. The DOCSIS protocol is deployed by cable operators worldwide. + +The DOCSIS protocol has had significant updates on both the physical and the MAC layers since DOCSIS 1.0. The most recent version is DOCSIS 3.1 (see Cable Labs CM-SP-MULPI [7]), with improvements to support higher symmetrical speeds and lower latency. Work is under way to support even higher speeds in the near future. + +These performance improvements make DOCSIS a viable transport technology for mobile traffic. Furthermore, the ubiquity of the HFC plants has the potential to make DOCSIS transport an economical solution. + +![Figure A.6: DOCSIS Transport Network diagram. The diagram shows a network architecture starting from a 'Mobile Core' and 'Residential business services' (green boxes) connected to a 'CMTS Core' (green box). The CMTS Core is connected via a 'Converged Interconnect Network - CIN (fiber)' to an 'Optical node (may include Remote PHY Device)' (blue triangle in a dashed circle). This optical node is connected to a 'Coax (including amplifiers, taps)' (black line). The coax line then branches out to four 'CM' (Cable Modem) units (green boxes). Each CM unit is connected to a different type of device: a mobile phone, a server rack, a laptop, and a house.](8bd08dab913d966eb4f19d117ba0d6d9_img.jpg) + +Figure A.6: DOCSIS Transport Network diagram. The diagram shows a network architecture starting from a 'Mobile Core' and 'Residential business services' (green boxes) connected to a 'CMTS Core' (green box). The CMTS Core is connected via a 'Converged Interconnect Network - CIN (fiber)' to an 'Optical node (may include Remote PHY Device)' (blue triangle in a dashed circle). This optical node is connected to a 'Coax (including amplifiers, taps)' (black line). The coax line then branches out to four 'CM' (Cable Modem) units (green boxes). Each CM unit is connected to a different type of device: a mobile phone, a server rack, a laptop, and a house. + +**Figure A.6: DOCSIS Transport Network** + +### A.2.1 DOCSIS resource scheduling + +In a DOCSIS network, the cable modem termination system (CMTS) is the master controlling multiple cable modem slaves (CMs). Most upstream data are transmitted using the best effort (BE) scheduling service. The DOCSIS upstream uses a request-grant approach as shown in Figure A.7. A request message is sent from the CM to the CMTS. The CMTS prepares a bandwidth allocation map, called the MAP, and inserts an entry indicating a grant for the CM. The grant entry in the MAP message contains an upstream service identifier (SID) associated with a service flow assigned to the CM, a + +transmission time signaled as a minislot number, and the number of minislots assigned. Based on the number of assigned minislots, the CM knows the number of bytes that have been granted. The CMTS broadcasts the MAP to the CM, so that the CM can make use of the grant to send its upstream data to the CMTS at the scheduled time. + +![Figure A.7: DOCSIS Request-Grant Scheduling diagram showing the interaction between CMTS and CM over time.](f752841fd2a33644fe419114e8e1ce19_img.jpg) + +The diagram illustrates the DOCSIS Request-Grant Scheduling process between a CMTS (Cable Modem Termination System) and a CM (Cable Modem) over time. The CMTS timeline at the top shows three main events: 'CMTS frame receive, processing, scheduling, MAP generation', 'egress data to mobile core', and 'data'. The CM timeline at the bottom shows 'data arrival at CM, wait for REQ opportunity', 'REQ' (request), 'MAP (grant)', and 'CM MAP lead time'. Arrows indicate the flow of data and control signals: a request arrow from CM to CMTS, a grant arrow from CMTS to CM, and a data arrow from CM to CMTS. The 'CM MAP lead time' is the period between the CM receiving the MAP and the CMTS egressing data to the mobile core. + +Figure A.7: DOCSIS Request-Grant Scheduling diagram showing the interaction between CMTS and CM over time. + +**Figure A.7 : DOCSIS Request-Grant Scheduling** + +Each CM can have multiple service flows. A service flow is defined by a set of quality of service (QoS) parameters, including scheduling priority. Within each service flow, the data are concatenated and fragmented. + +In addition to the BE scheduling service, the CMTS can choose to grant the CM on a periodic basis via unsolicited grant service (UGS) scheduling service, or proactive grant service (PGS). UGS was originally designed for carrying VoIP data, transmitting a fixed and discreet amount of traffic at a relatively fixed time interval. PGS is an update to UGS: it permits the flexibility for CM to concatenate and fragment the data. All DOCSIS scheduling services are reactive, in that the CMTS reacts to conditions such as a CM request or a preconfiguration on the DOCSIS channel. While PGS permits the CMTS to adjust the amount of periodic grants and the periodicity, the CMTS still reacts based on the past information. + +### A.2.2 DOCSIS Latency Analysis + +The upstream latency on a DOCSIS network consists of several components. + +#### A.2.2.1 CIN Network Latency + +The cable industry has been virtualizing and splitting the functionalities of their access network equipment since the early 2010 timeframe. The distributed architecture splits the traditional CMTS into an intelligent core unit residing in a hub, a headend, or even a regional data center, with remote units that have minimal functionality residing in a fiber node close to the CM. The converged interconnect network (CIN) is the fiber network that connects a CMTS core to the remote units. + +The propagation delay between the CMs and the remote units is negligible due to the short coax run between them. However, the CIN vary between operators, and can be between 30 km and upwards. Therefore, depending on operator requirements, CIN delay could need to be considered when operators plan their fronthaul delay budgets. + +Reducing CIN delay is not the focus of this interface protocol. + +#### A.2.2.2 Channel Access Latency + +Channel access latency is a result of the shared-medium scheduling provided by DOCSIS technology, in which the CMTS arbitrates access to the upstream channel via a request-grant mechanism. + +The CMTS scheduler typically processes REQs every 2 ms and generates a MAP that describes 2 ms worth of grant allocations. MAPs are scheduled one MAP interval in advance. Additionally, the CMTS and the CM each need processing time which can range from 0.5 to 1 ms on each device. So the theoretical minimum upstream latency for DOCSIS is about 5 ms. Recent work to improve DOCSIS upstream latency include requiring a smaller MAP interval, as well as a shorter CMTS processing time. Still, these efforts only reduces minimum achievable latency. The channel access latency on a + +DOCSIS network is load dependent. During periods of temporary congestion, channel access latency can increase to 10's of milliseconds. + +The bandwidth report (BWR) and the CTI protocols both aim to significantly reduce the channel access latency. + +#### A.2.2.3 Other Components + +Other sources of latency include serialization delay and switching / forwarding delay. They generally result in significantly less latency than the two above, and are not the target of this specification. + +### A.2.3 Bandwidth Report (BWR) + +The bandwidth report (BWR) protocol is standardized at the CableLabs DOCSIS Xhaul committee with many contributing cable and mobile infrastructure companies in Cable Labs CM-SP-LLX [6]. BWR significantly reduces the latency of mobile traffic when traversing the DOCSIS network. The protocol is designed for when DOCSIS network provides backhaul, midhaul, and fronthaul transport for a mobile system. Figure A.8 shows BWR transmitting across the DOCSIS xhaul network. + +![Figure A.8: BWR Transits Across Xhaul. The diagram illustrates three network architectures where BWR (Bandwidth Report) is transmitted from the O-DU to the CMTS. In the top architecture (Backhaul), the O-DU is an eNB/gNB connected to a CM via DOCSIS Backhaul. In the middle architecture (Midhaul), the O-DU is a DU connected to a CM via DOCSIS Midhaul. In the bottom architecture (Fronthaul), the O-DU is a DU connected to a CM via DOCSIS Fronthaul. In all cases, the BWR is sent from the O-DU to the CMTS, which then forwards it to the Mobile Core. The BWR is represented by a red dashed arrow labeled 'BWR'.](4602bf6139e5162e21a094adbd9a6376_img.jpg) + +Figure A.8: BWR Transits Across Xhaul. The diagram illustrates three network architectures where BWR (Bandwidth Report) is transmitted from the O-DU to the CMTS. In the top architecture (Backhaul), the O-DU is an eNB/gNB connected to a CM via DOCSIS Backhaul. In the middle architecture (Midhaul), the O-DU is a DU connected to a CM via DOCSIS Midhaul. In the bottom architecture (Fronthaul), the O-DU is a DU connected to a CM via DOCSIS Fronthaul. In all cases, the BWR is sent from the O-DU to the CMTS, which then forwards it to the Mobile Core. The BWR is represented by a red dashed arrow labeled 'BWR'. + +**Figure A.8 : BWR Transits Across Xhaul** + +Since this transport plane specification focuses on the fronthaul transport, this specification only considers BWR in fronthaul transport. + +#### A.2.3.1 BWR Principles of Operations + +Ordinarily, without BWR, the CM waits for the fronthaul data to arrive from the O-RU and then makes bandwidth requests using the native DOCSIS request mechanism. The mobile data transfer from the UE to the O-RU takes a 3-way request-grant loop, and then the transfer of fronthaul data on the DOCSIS link takes another 3-way request-grant loop. Since DOCSIS and mobile networks are two independent systems, the two similar scheduling loops take place in serial. + +With BWR, the O-DU informs the CMTS when it performs the uplink scheduling about the number of bytes that is about to come to the CM from the O-RU at a certain time in the future. The BWR replaces the CM's internal layer 2 request message for the fronthaul data arriving at the CM. The BWR message itself is an external layer 3 IP or Ethernet-based message that is transmitted from the O-DU, directly to the CMTS. The content of the BWR is populated with information describing data that will arrive at the CM in the future. + +With this information, the CMTS has the ability to make scheduling decisions for the fronthaul data that is about to arrive but before its actual arrival at the CM. BWR enables DOCSIS and mobile systems to work together by defining an + +interface that allows the O-DU to share fronthaul scheduling information with the CMTS. In this way, the two similar scheduling loops take place in parallel. As a result, BWR reduces the latency on the DOCSIS link. + +BWR message enables QoS support on the DOCSIS network via the CTI Flow ID. Fronthaul traffic is sorted into priority classes and assigned a DOCSIS Service Flow ID. BWR message includes one or multiple CTI Flow IDs and their associated bytes. There is a common understanding between the CTI Flow ID and the priority between the CMTS and the O-DU, so that the CMTS can prioritize traffic based on the CTI Flow ID. + +To allow for the flexibility to provide lower latency on the fronthaul transport, the CMTS could need to schedule transport grants as the fronthaul traffic arrives at the CM rather than at the end of the slot. BWR protocol defines the concept of traffic pattern in subintervals within the time interval the BWR message describes, and by doing so, the BWR message provides a more granular traffic arrive information to the CMTS. + +Details of the message exchange, as well as the interface protocol can be found in Cable Labs CM-SP-LLX [6]. + +![Figure A.9: BWR Message Flow for Fronthaul. The diagram consists of two sequence diagrams, (a) Without BWR and (b) With BWR, showing the interaction between UE, RU, CM, CMTS, and DU/CU. In (a), the flow is: UE sends BSR to RU, RU sends BSR(s) to CM, CM sends MAP for BSR to CMTS, CMTS sends BSR(s) to RU, RU sends UL grant to CM, CM sends UL grant to DU/CU, DU/CU sends UL scheduling, grant generation to CMTS, CMTS sends UL grant to RU, RU sends UL grant to UE, UE sends UL data + BSR to RU, RU sends REQ to CM, CM sends MAP to CMTS, CMTS sends UL data + BSR to RU, RU sends UL data arrival to DU/CU. In (b), the flow is: UE sends BSR to RU, RU sends BSR(s) to CM, CM sends MAP for BSR to CMTS, CMTS sends BSR(s) to RU, RU sends UL grant to CM, CM sends UL grant to DU/CU, DU/CU sends UL scheduling, grant generation to CMTS, CMTS sends UL grant to RU, RU sends UL grant to UE, UE sends UL data + BSR to RU, RU sends MAP to CM, CM sends UL data to CMTS, CMTS sends BWR message: UL grant summary to RU, RU sends UL data arrival to DU/CU.](e1893c9fa0d75477beee7c73a59ca29b_img.jpg) + +Figure A.9: BWR Message Flow for Fronthaul. The diagram consists of two sequence diagrams, (a) Without BWR and (b) With BWR, showing the interaction between UE, RU, CM, CMTS, and DU/CU. In (a), the flow is: UE sends BSR to RU, RU sends BSR(s) to CM, CM sends MAP for BSR to CMTS, CMTS sends BSR(s) to RU, RU sends UL grant to CM, CM sends UL grant to DU/CU, DU/CU sends UL scheduling, grant generation to CMTS, CMTS sends UL grant to RU, RU sends UL grant to UE, UE sends UL data + BSR to RU, RU sends REQ to CM, CM sends MAP to CMTS, CMTS sends UL data + BSR to RU, RU sends UL data arrival to DU/CU. In (b), the flow is: UE sends BSR to RU, RU sends BSR(s) to CM, CM sends MAP for BSR to CMTS, CMTS sends BSR(s) to RU, RU sends UL grant to CM, CM sends UL grant to DU/CU, DU/CU sends UL scheduling, grant generation to CMTS, CMTS sends UL grant to RU, RU sends UL grant to UE, UE sends UL data + BSR to RU, RU sends MAP to CM, CM sends UL data to CMTS, CMTS sends BWR message: UL grant summary to RU, RU sends UL data arrival to DU/CU. + +**Figure A.9 : BWR Message Flow for Fronthaul** + +#### A.2.3.2 Using CTI for BWR + +CTI uses the basic mechanism that BWR uses that requires the O-DU to communicate to the CMTS via a transport plane interface. + +Both mechanisms require connecting the O-DU and the CMTS via logical interfaces. In both cases, the O-DU determines the amount of fronthaul allocations for a time interval and for a service. About the same time as O-DU sends O-RU the C-plane message about U-plane data for the time interval, the O-DU formulates and sends a CTI message to the CMTS. For both types (BWR and CTI) of messages, a common set of information elements are needed: + +- Unique ID to indicate the O-RU's physical interface +- Start time +- End time: the start time and end time together defines the time interval that is associated with the bytes +- QoS / priority ID: in the BWR case, priority is indicated. In the CTI case, a combination of priority and latency class can be indicated +- Bytes associated with each QoS / priority ID +- Traffic pattern ID to describe bytes in subintervals within the time interval + +The CMTS maps the QoS / priority ID to the DOCSIS upstream service ID (SID), and schedules transport grants according to CMTS scheduler and policy rules. + + + +# Revision History + +| Date | Revision | Description | +|------------|----------|------------------------------------------------------------------------------------------------| +| 2023.02.07 | 04.00 | Alignment on O-RAN template, various clarifications | +| 2022.07.14 | 03.00 | Clarification on TC & TM terminology | +| 2021.03.03 | 02.00 | Updated with specifications for EtherType, uplink C-Plane messages, and CTI pattern descriptor | +| 2020.03.13 | 01.00 | Final version 01.00 | + +# History + +| Date | Revision | Description | +|------------|----------|----------------------------------| +| 2023.02.07 | 04.00 | Published as Final version 04.00 | +| 2022.07.14 | 03.00 | Published as Final version 03.00 | +| 2021.03.03 | 02.00 | Published as Final version 02.00 | +| 2020.03.13 | 01.00 | Published as Final version 01.00 | \ No newline at end of file diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/1bce5115afe14f9c2b1106cbffe790fe_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/1bce5115afe14f9c2b1106cbffe790fe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0f3899bf918bd0be7c42cf43767108874d3c5c61 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/1bce5115afe14f9c2b1106cbffe790fe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fb2fb1d2d9407835a9758bcdcac344f044a739c041879ca890ffc08af4680a4c +size 60180 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/1f12953abd9f88f5c5455f100f110994_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/1f12953abd9f88f5c5455f100f110994_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..808051b71fcc1cd1be2a7c43e84a12f2eb99b86e --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/1f12953abd9f88f5c5455f100f110994_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dc888ab81cbd1632b5224abc5e8bc7d4585d59c77615985441870c84e5717c34 +size 4529 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/2c8e1715dc65759daa895a3d291d05a0_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/2c8e1715dc65759daa895a3d291d05a0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..93412ba1e6b7158161333dd4301e4079f7bdd945 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/2c8e1715dc65759daa895a3d291d05a0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6e9cdba31278c20458dd0f326a88d6ab765adc2456ae8a928569fdc18ef7dc32 +size 12396 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/2dd4d8b8c90bd4995ac92296ce44c708_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/2dd4d8b8c90bd4995ac92296ce44c708_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2570e874fc3c74d6c0ea3ecdcfc68c187e723369 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/2dd4d8b8c90bd4995ac92296ce44c708_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4574e493d7351d4dd866b13bd5c5e4e51990d538c9445c744ac5d462b919eb16 +size 4506 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/37d9c9813c6708a6f041679c09d1533f_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/37d9c9813c6708a6f041679c09d1533f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a78c56798bdd2239196c62bb963bdc9426009bd1 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/37d9c9813c6708a6f041679c09d1533f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fcd5ae1d74873f2fcfd1f8f9e3d493c16fa7d9c715080a3490e3f08c305144ee +size 63135 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/4084850bc6febdc92c5e87c12cab7001_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/4084850bc6febdc92c5e87c12cab7001_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5ee8b6c0df3476df4e078ca842bbbfde24265750 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/4084850bc6febdc92c5e87c12cab7001_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8437828cdbc01234f81f655769efe8e9a66d019fb69e4c9119d3d1d818d93143 +size 38058 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/4a108205d3a562dde10e047b6cc3f6f7_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/4a108205d3a562dde10e047b6cc3f6f7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d78c9361c0003a321cbffd6f6c7c20e6940727a1 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/4a108205d3a562dde10e047b6cc3f6f7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:24bdce4b416ee968187ed06e8708da53c8543c3f62470ac5ef870dc72c4a3d51 +size 4505 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/52bde0bfbb6eac89939443eebd729795_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/52bde0bfbb6eac89939443eebd729795_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..130bea1da3424b949f6c36f232e3f39a5263cd2d --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/52bde0bfbb6eac89939443eebd729795_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:acd0182ccd780ca552f7455b45a4c867bb269f637d46fdaee2a4d126f404a109 +size 59989 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/5f7caf91d90782b98b1427d9ad734df8_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/5f7caf91d90782b98b1427d9ad734df8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ed085c88fa0e2ea3d040cfefa014eddd3f62e35d --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/5f7caf91d90782b98b1427d9ad734df8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e822cd78f756e77817c024fc592dd1868d16fa28bec4fa19fe0cfe3fb18fe136 +size 109680 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/646622819b5259c1e7e4374e0e5698b1_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/646622819b5259c1e7e4374e0e5698b1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..392deebac09b26cf955731a37a60e03516c68d94 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/646622819b5259c1e7e4374e0e5698b1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ead6d67ec139a3687a2120d37536ff517a800dbc00c25c8d1e66c4a27f51a33f +size 79051 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/710422145a91e48f6e1bb113e89931ff_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/710422145a91e48f6e1bb113e89931ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7db9fdbb9fa032d50a32357af17f97b0e19b3d6d --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/710422145a91e48f6e1bb113e89931ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:75b0a15c46f5cbddffceb04d4f836fe60bdc494aaeefde4d475c72daf19559a2 +size 35346 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/71b87d388380993574d17e54e05f1939_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/71b87d388380993574d17e54e05f1939_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7dfd729fa5ad1ed575bd843aa194533bfef2e761 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/71b87d388380993574d17e54e05f1939_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7e07e28719ebd117c94c0daf0846ca68e1decd3e914c5aad0aa9b18b87d88d72 +size 4510 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/74e986e750dde19f0001c8188c89a679_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/74e986e750dde19f0001c8188c89a679_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7769d4a0e4c5bb8e0ec2e6b670566d30391e519e --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/74e986e750dde19f0001c8188c89a679_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:306b1f8eb89268a68b6f6f19e067c31910d3fa7e307b0dc6d739b09fd676e276 +size 4558 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/7eb6195a66f16556745601b70664848e_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/7eb6195a66f16556745601b70664848e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5a4f072fad31c532d3ab745a0a384e25324fbd55 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/7eb6195a66f16556745601b70664848e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e40c2833b745045abdda6d6818a357af1155de2b5d1c5118e26a2fd47dabcbc3 +size 143299 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/83dc925549bda401a52b416333d32e3d_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/83dc925549bda401a52b416333d32e3d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3bce7ab97fd438e6ffc3d806acc0f10057d0941b --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/83dc925549bda401a52b416333d32e3d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0b475b6385fde62356c4ca14e2601f1389ccc9580dfd26723462b26172423073 +size 4506 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/870bbcba367d54939396306b683c9129_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/870bbcba367d54939396306b683c9129_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8b918fd8a11d55d2b37d6967fc574c7968ef5d31 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/870bbcba367d54939396306b683c9129_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3fbbe22bcd09e12f4357612b02aedeb2c23ce89d059a30b144ba158a2aa5da32 +size 4557 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/87e2ff7a747555c9aa45f4136188bb94_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/87e2ff7a747555c9aa45f4136188bb94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f87cfae8379ad05f07acb84db9668dc0df245e91 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/87e2ff7a747555c9aa45f4136188bb94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ae3e87355997dcaa9f0d550d0a4d16547caf577ba39120a05d221fbc1999c87 +size 4531 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/8fae5b0fa08809d3828149e3aff278b9_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/8fae5b0fa08809d3828149e3aff278b9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..75bfa77f37486a886c15f3614c1f03242b334ae9 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/8fae5b0fa08809d3828149e3aff278b9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7e450ad763cdefc6d10891ec15dbdb68195bcece181b0c0c04901343a0ad713d +size 82940 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/9a26b6d027f53c0069d24d600cc18fae_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/9a26b6d027f53c0069d24d600cc18fae_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eee21af33583cff2241d4225cd27afc452b9865c --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/9a26b6d027f53c0069d24d600cc18fae_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8d5abe26fb5767a9013f3c5ee6ad4666ed2d82e3a1019b52bc4b2e482714f697 +size 4545 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/b1f9bcd4965daf57ecac593b5667a702_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/b1f9bcd4965daf57ecac593b5667a702_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8a9b092e0b87f6879246a13e431f3749f0dc9248 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/b1f9bcd4965daf57ecac593b5667a702_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8f982e95e7072886b56b4cd663646444ab8c631c996700264ca412cf444cde72 +size 76071 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/b4cc57a0dafacbb51428df1438c55676_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/b4cc57a0dafacbb51428df1438c55676_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd9a8e4b43e1d29152e2e6fb34b68ac22940f410 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/b4cc57a0dafacbb51428df1438c55676_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9032ee7fda71a0aa9efc06980697aacdf5ca2255ffacdd7c84c79f8024ce2037 +size 140606 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/bb82b02cd9670b140a2f7d1e1fa563ca_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/bb82b02cd9670b140a2f7d1e1fa563ca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c81a13b5e2189fe82400a8181e121ce2892d5a47 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/bb82b02cd9670b140a2f7d1e1fa563ca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:77ec5cbe47faa5adf430b6e878f1f0b5bf7eebfb367300ac605bfb426e559c9a +size 83403 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/bdadcf4ab22d1254f91aa6359282b10d_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/bdadcf4ab22d1254f91aa6359282b10d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..835b6597b2686497b057631073388d915385df6b --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/bdadcf4ab22d1254f91aa6359282b10d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4f7935ac81d78250f2e5022fdd779d4fe9bef0b23e9a19f9189319f2295cdf82 +size 46916 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/cd644c4cc32c6b5cdb2099f355194261_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/cd644c4cc32c6b5cdb2099f355194261_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5afb06f305359836f42cc57f9934f6569ebab526 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/cd644c4cc32c6b5cdb2099f355194261_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e213374db7697b2371d0975aaea8f945c9f9115786b1e4f687ccd1bd0129b557 +size 4502 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/cf6bd9ff33df5fe5a08f2cf4cf1886c6_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/cf6bd9ff33df5fe5a08f2cf4cf1886c6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fc7497a3c10022a213ea62b4c6484252253f87e7 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/cf6bd9ff33df5fe5a08f2cf4cf1886c6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d866e18b765aca8775d323010cafa6453d4649dd50257485f5d6ed2e9a0fb19 +size 61098 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/e44a0bb164141faab1727fe3b24cad0c_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/e44a0bb164141faab1727fe3b24cad0c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5262338ee4021d0772db5f95cbbaf808e5e6248a --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/e44a0bb164141faab1727fe3b24cad0c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f5aba8bde2a64b81a9293433080bee541e61d4f6f20377377f6aaaa2f383b4be +size 87807 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/f59a4206f53387f2b304bd7fb7dd7e19_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/f59a4206f53387f2b304bd7fb7dd7e19_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..444a399b4bff957efb458dddafb65bf81133675a --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/f59a4206f53387f2b304bd7fb7dd7e19_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a90542417d1df8f91a47b68ee58110ab7665f34b379662386b59153f8a8d0aa6 +size 4458 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/fd15e7b2d22fc764649a1d1ba9e48f27_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/fd15e7b2d22fc764649a1d1ba9e48f27_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2fdc0cca097dfd2b92c24144a64af7ed13c35568 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/fd15e7b2d22fc764649a1d1ba9e48f27_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6a040ffda790e1c45aaa90636bbfa29a5a1ba17b2f48526994a079385d7ae6ba +size 191525 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/fd299b6990751cdd7933674a230992f4_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/fd299b6990751cdd7933674a230992f4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e9e3b892dba8d2bcc586c473f5d99a93c186ca74 --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/fd299b6990751cdd7933674a230992f4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:175486d10a8d942711fb10f228a7afed307aec9825f8c3a0102b8286c3172981 +size 4579 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/ffd1ce05af53f7228fdc36bb1e8cf17b_img.jpg b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/ffd1ce05af53f7228fdc36bb1e8cf17b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3506598865886ce0e8f617956fbb63a616707f3e --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/ffd1ce05af53f7228fdc36bb1e8cf17b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9c67f85a07775213dea339b21d6fd7fdd94575b9c005c6cc6df6b137c1abe8a1 +size 68077 diff --git a/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/raw.md b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..d0d0c215ed33e96e62321a007ecfe0da7c6b1ecf --- /dev/null +++ b/marked/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00/raw.md @@ -0,0 +1,2525 @@ + + +# --- **O-RAN Working Group 4 (Open Fronthaul Interfaces WG)** + +## **Cooperative Transport Interface Transport Management Procedures Specification** + +Copyright © 2023 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# Contents + +| | | | +|----|-----------------------------------------------------------------------------------------------------------------------|----| +| 1 | Foreword..... | 4 | +| 2 | Modal verbs terminology ..... | 4 | +| 3 | 1 Scope..... | 5 | +| 4 | 2 References..... | 5 | +| 5 | 2.1 Normative references..... | 5 | +| 6 | 2.2 Informative references..... | 6 | +| 7 | 3 Definition of terms, symbols and abbreviations..... | 6 | +| 8 | 3.1 Terms..... | 6 | +| 9 | 3.2 Abbreviations..... | 7 | +| 10 | 4 High Level Description ..... | 9 | +| 11 | 4.1 General CTI Management Architecture..... | 9 | +| 12 | 4.1.1 Foreword on management domains ..... | 9 | +| 13 | 4.1.2 Summary of architecture ..... | 9 | +| 14 | 4.1.3 Parameters to be configured..... | 9 | +| 15 | 5 CTI Management..... | 10 | +| 16 | 5.1 CTI connectivity parameters and configuration..... | 10 | +| 17 | 5.1.1 Point-point or switched Ethernet connectivity between TN and O-DU ..... | 10 | +| 18 | 5.1.2 IP routing connectivity between TN and O-DU..... | 11 | +| 19 | 6 CTI procedures..... | 15 | +| 20 | 6.1 Correlations to be performed ..... | 15 | +| 21 | 6.2 Auto Discovery for correlation of CTI session ID to transport parameter in TN ..... | 16 | +| 22 | 6.2.1 Switched Ethernet connectivity between O-RU and O-DU ..... | 17 | +| 23 | 6.2.2 IP routing connectivity between O-RU and O-DU ..... | 17 | +| 24 | 6.3 Auto discovery for correlation of CTI session ID to CTI server..... | 18 | +| 25 | 6.4 Performing correlations without Auto Discovery method ..... | 18 | +| 26 | 7 CTI Information Model ..... | 20 | +| 27 | 7.1 General structure of the Information Model ..... | 20 | +| 28 | 7.2 Relationships and unicities in the context of encapsulation of CTI flows between CTI servers and CTI clients..... | 22 | +| 29 | 7.3 Relationships and unicities in the context of CTI sessions, CTI flows, CTI Patterns..... | 23 | +| 30 | 7.4 CTI IM for O-DU ..... | 24 | +| 31 | 7.4.1 Imported and associated information ..... | 24 | +| 32 | 7.4.2 Relationships at O-DU CTI Client ..... | 24 | +| 33 | 7.4.3 Inheritance..... | 27 | +| 34 | 7.4.4 Class and Type definitions ..... | 27 | +| 35 | 7.4.5 Attribute definitions ..... | 34 | +| 36 | 8 CTI YANG Data Model..... | 44 | +| 37 | 8.1 CTI YANG Data Model Related to O-DU ..... | 45 | +| 38 | 8.1.1 Overview..... | 45 | +| 39 | 8.1.2 o-ran-cti-common..... | 45 | +| 40 | 8.1.3 o-ran-ol-ctiOdu..... | 45 | +| 41 | 8.2 CTI YANG Model Related to TN (informative)..... | 46 | +| 42 | 8.2.1 Overview..... | 46 | +| 43 | 8.2.2 o-ran-cti-common..... | 47 | +| 44 | 8.2.3 o-ran-cti-tn-generic..... | 47 | +| 45 | 8.2.4 o-ran-cti-tn-pon ..... | 48 | +| 46 | 8.2.5 o-ran-cti-tn-docsis ..... | 49 | +| 47 | Annex A O-DU YANG Module Graphical Representation..... | 51 | +| 48 | A.1 CTIFunction..... | 51 | + +| | | | | +|---|------------------------|----------------------------------------|----| +| 1 | Annex B | TN YANG Data Models (Informative)..... | 53 | +| 2 | B.1 | o-ran-cti-tn-generic.yang..... | 53 | +| 3 | B.2 | o-ran-cti-tn-pon.yang ..... | 57 | +| 4 | B.3 | o-ran-cti-tn-docsis.yang ..... | 60 | +| 5 | Revision History ..... | | 63 | +| 6 | History ..... | | 63 | +| 7 | | | | +| 8 | | | | + +# --- Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# 1 Scope + +This Technical Specification has been produced by the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Release xx.yy.zz + +where: + +xx the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). + +yy the second digit-group is incremented when editorial only changes have been incorporated in the document. + +zz the third digit-group included only in working versions of the document indicating incremental changes during the editing process. + +The present document describes the Transport Management Procedures for the Cooperative Transport Interface (CTI). CTI is an interface between O-DUs and Transport Nodes of a packet-based transport network that is used to interconnect the O-DUs to a variety of O-RUs. CTI specifically targets transport Nodes that manage a shared point-to-multipoint access network. Intermediate transport nodes (routers and switches) that only manage point-to-point links do not exchange CTI messages with the O-DUs. CTI consists of a Transport Control plane (TC) and a Transport Management (TM). This document specifies the TM Information Model / Data Model and procedures. The TC-plane is described in [1]. The reader is referred to the TC-plane document for a description of the protocol as well as background, context, motivation and topologies with CTI. + +This document focuses on the management aspect of CTI. The goals are to define the CTI-related configurable parameters at TN and at O-DU, to define a suitable set of YANG modules to capture these parameters, to describe necessary steps in the configuration of the parameters, and to define an auto-discovery method to automate the correlation between TN specific parameters and CTI parameters. + +# 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN.WG4.CTI-TCP.0-v03.00 “Cooperative Transport Interface, Transport Control Plane Specification” +- [2] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. +- [3] ORAN-WG4.CUS.0-v09.00 “Control, User and Synchronization Plane Specification”. +- [4] ORAN-WG4.MP.0-v09.00 “Management Plane Specification”. +- [5] Broadband Forum TR-385 “ITU-T PON YANG modules” +- [6] Broadband Forum TR-383 “Common YANG Modules for Access Networks” + +- [7] IETF RFC 6991 “Common YANG datatypes” +- [8] IETF RFC 8343 “A YANG Data Model for Interface Management” +- [9] IETF RFC 8344 “A YANG Data Model for IP Management” +- [10] CableLabs CM-SP-MULPIv3.1-I19-191016, “DOCSIS 3.1 MAC and Upper Layer Protocols Interface Specification”, Cable Television Laboratories, Inc + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [11] IETF RFC 3046 “DHCP Relay Agent Information Option” +- [12] IETF RFC 3315 “Dynamic Host Configuration Protocol for IPv6 (DHCPv6)” +- [13] IETF RFC 2132 “DHCP Options and BOOTP Vendor Extensions” +- [14] IETF RFC 3925 “Vendor-Identifying Vendor Options for Dynamic Host Configuration Protocol version 4 (DHCPv4)” +- [15] IETF RFC 6939 “Client Link-Layer Address Option in DHCPv6” +- [16] IETF RFC 6991 “Common YANG Data Types” +- [17] 3GPP TS 32.160 Management and orchestration; Management service template (Release 16) +- [18] 3GPP TS 32.156 Fixed Mobile Convergence (FMC) Model repertoire (Release 16) + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [2] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [2]. + +New terms used in this document: + +- **CTI client:** a process in the O-DU that exchanges CTI messages with one or multiple CTI servers, e.g. to request a given transport capacity. +- **CTI server:** a process in the Transport Node that exchanges CTI messages with one or multiple CTI clients, e.g. to receive capacity requests. +- **CTI message sender:** CTI client or CTI server generating a CTI message +- **CTI message receiver;** CTI client or CTI server receiving a CTI message + +Generic terms used in this document: + +- **Mobile slot:** a subframe in 3GPP LTE or a slot in 3GPP NR. + +Conventions used in this document: + +- The following convention applies any time a bit field is displayed in a figure. The bit field shall be interpreted by reading the figure from left to right, then from top to bottom, with the MSB being the first bit so read and the LSB being the last bit so read. + +## 3.2 Abbreviations + +For the purposes of the present document, the following abbreviations apply. + +| | | +|--------------|-------------------------------------------------| +| BWR | Bandwidth Reporting | +| CM | Cable Modem | +| CMTS | Cable Modem Termination System | +| CoS | Class of Service | +| CO DBA | Cooperative DBA | +| CTI | Cooperative Transport Interface | +| DBA | Dynamic Bandwidth Allocation | +| DHCP | Dynamic Host Configuration Protocol | +| DM | Data Model | +| DN | Distinguished Name | +| DOCSIS | Data Over Cable Service Interface Specification | +| DP | Destination Port | +| DSCP | Differentiated Services Code Point | +| DT | Data Type | +| EMS | Element Management System | +| FQDN | Fully Qualified Domain Name | +| IM | Information Model | +| IOC | Information Object Class | +| L2 / L3 / L4 | ISO/OSI Layer 2 / Layer 3 / Layer 4 | +| LLID | Logical Link ID | +| MAC | Media Access Control | +| MOI | Managed Object Instance | +| NA(P)T | Network Address (and Port) Translation | +| NMS | Network Management System | +| O-CU | O-RAN Central Unit | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| OLT | Optical Line Termination | +| ONU | Optical Networking Unit | +| OSS | Operations Support System | +| PCP | Priority Code Point | +| PON | Passive Optical Network | +| QoS | Quality of Service | +| RAN | Radio Access Network | + +| | | | +|----|--------|--------------------------------------| +| 1 | RO | Read-Only | +| 2 | SCN | Service Class Name | +| 3 | SF | Service Flow | +| 4 | SMO | Service Management and Orchestration | +| 5 | SN | IP subnet | +| 6 | SP | Source Port | +| 7 | T-CONT | Transmission Container | +| 8 | TC | Traffic Class for IPv6 | +| 9 | TC(P) | Transport Control (Plane) | +| 10 | TDM | Time Division Multiplexing | +| 11 | TM(P) | Transport Management (Procedures) | +| 12 | TN | Transport Node | +| 13 | ToS | Type of Service | +| 14 | TPID | Tag Protocol Identifier | +| 15 | TU | Transport Unit | +| 16 | UDP | User Datagram Protocol | +| 17 | UE | User Equipment | +| 18 | VID | VLAN ID | +| 19 | VLAN | Virtual LAN | +| 20 | | | + +# 4 High Level Description + +## 4.1 General CTI Management Architecture + +### 4.1.1 Foreword on management domains + +This document refers to separate “transport domain OSS” and “RAN domain SMO”, without any implication of ownership of the domains or use of particular processes or protocols in the transport domain OSS. Each domain is responsible for managing its nodes and can do so independently, but for CTI some level of mutual coordination is needed. + +Note that using two domains in this document does not preclude alternative approaches such as an integrated OSS for both domains, or an overarching orchestrating function that would select the parameters and forward them to the OSS domains. + +### 4.1.2 Summary of architecture + +As the configuration of CTI parameters in the O-DU is non real-time, it shall be done over the O-RAN O1 interface using NETCONF/YANG. + +This document does not make assumptions about the management process in the Transport OSS. + +Several CTI parameters are common for O-DU and TN side and have to be aligned. There is a need for coordination between both operation domains. This document specifies the needs, but does not make assumptions about the process or protocols to ensure such coordination. The only process described in this document is an automated auto-discovery which allows to link a TN specific transport parameter with each individual CTI session ID. + +This document does not make assumptions about the integration of functional features into physical nodes. For example, the document does not restrict the realization of the RAN domain DHCP server, which can be integrated with the O-DU, can be provided by the transport system, or can be accessed via a relay. + +![Figure 4.1: Management architecture for CTI. The diagram shows three domains: RAN domain (left), Transport domain (middle), and RAN domain (right). In the left RAN domain, there is an O-RU connected to a TU. In the Transport domain, there is a TN box containing a DHCP relay agent and CTI server(s), connected to a Transport OSS box containing a DHCP server, NMS, and EMS. In the right RAN domain, there is an O-DU box containing a DHCP relay agent and CTI client(s), connected to a RAN SMO box containing NMS, EMS, and a DHCP server. A double-headed arrow labeled 'Coordination' connects the Transport OSS and RAN SMO. A double-headed arrow labeled 'O1' connects the RAN SMO and O-DU. A dashed box labeled 'Inter-mediate node' is between the TN and O-DU.](4084850bc6febdc92c5e87c12cab7001_img.jpg) + +Figure 4.1: Management architecture for CTI. The diagram shows three domains: RAN domain (left), Transport domain (middle), and RAN domain (right). In the left RAN domain, there is an O-RU connected to a TU. In the Transport domain, there is a TN box containing a DHCP relay agent and CTI server(s), connected to a Transport OSS box containing a DHCP server, NMS, and EMS. In the right RAN domain, there is an O-DU box containing a DHCP relay agent and CTI client(s), connected to a RAN SMO box containing NMS, EMS, and a DHCP server. A double-headed arrow labeled 'Coordination' connects the Transport OSS and RAN SMO. A double-headed arrow labeled 'O1' connects the RAN SMO and O-DU. A dashed box labeled 'Inter-mediate node' is between the TN and O-DU. + +**Figure 4.1 : Management architecture for CTI** + +### 4.1.3 Parameters to be configured + +There are two types of parameters related to CTI: + +- Parameters to establish L2 or L2 + L3/L4 connectivity for CTI messages between CTI servers and CTI clients, to be configured by Transport OSS and by RAN SMO, and their corresponding YANG models +- Parameters for the operation of CTI, to be configured by Transport OSS and by RAN SMO, and their corresponding YANG models + +# 5 CTI Management + +## 5.1 CTI connectivity parameters and configuration + +This chapter describes how to enable CTI connectivity between the CTI servers and CTI clients. It is a conceptual description of the configuration needs and does not specify protocols or methods or sequences of actions for the configuration. + +### 5.1.1 Point-point or switched Ethernet connectivity between TN and O-DU + +#### 5.1.1.1 L2 Connectivity parameters + +The packets shall follow the Ethernet encapsulation as described in O-RAN CTI TCP [1]. + +The CTI packets are encapsulated in Ethernet with the invariant value of O-RAN Ethertype (0x9433), so the Ethertype is not configurable. The Ethernet Protocol Subtype (see O-RAN CTI TCP [1]) for O-RAN CTI is also an invariant value but not formally specified yet, so it is made configurable (value 0x1 is proposed in [1]). + +Note: This version of the document only specifies the use of single (.1Q) VLAN tag for CTI transport and L2 filter parameter. The use of dual VLAN-tag is to be specified in a later version of this document. + +Both O-DU and TN need to know the corresponding VLAN(s) and MAC addresses of respectively the CTI servers and CTI clients they have to connect to. As mentioned in O-RAN CTI TCP [1], each TN may host multiple CTI servers, each O-DU may host multiple CTI clients, and connectivity between all clients and servers shall be supported. + +The operator is free to choose how to segment the network with different VLANs, from a single flat model (option A: same VLAN configuration for CTI in the whole network) to differentiation (a VLAN configuration per TN-O-DU pair (Option B) or per client-server pair (Option C)). + +![Figure 5.1: Layer 2 interconnection options. The diagram illustrates three options for Layer 2 connectivity between Transport Network (TN) servers and O-DU clients. Option A shows a flat model with a single VLAN for all connections. Option B shows a differentiated model with a VLAN per TN-O-DU pair. Option C shows a differentiated model with a VLAN per server-client pair. Each option includes a diagram showing the connectivity between servers (A1, ..., An) and clients (X1, ..., Xn) across two TNs (A and B) and two O-DUs (X and Y). Option A has a single blue box labeled '1 VLAN for all'. Option B has a blue box labeled '1 VLAN per TN-ODU pair'. Option C has a blue box labeled '1 VLAN per server-client pair'. Below each diagram, it is noted that '1 MAC addr per server' and '1 MAC addr per client' are required.](b1f9bcd4965daf57ecac593b5667a702_img.jpg) + +Figure 5.1: Layer 2 interconnection options. The diagram illustrates three options for Layer 2 connectivity between Transport Network (TN) servers and O-DU clients. Option A shows a flat model with a single VLAN for all connections. Option B shows a differentiated model with a VLAN per TN-O-DU pair. Option C shows a differentiated model with a VLAN per server-client pair. Each option includes a diagram showing the connectivity between servers (A1, ..., An) and clients (X1, ..., Xn) across two TNs (A and B) and two O-DUs (X and Y). Option A has a single blue box labeled '1 VLAN for all'. Option B has a blue box labeled '1 VLAN per TN-ODU pair'. Option C has a blue box labeled '1 VLAN per server-client pair'. Below each diagram, it is noted that '1 MAC addr per server' and '1 MAC addr per client' are required. + +Figure 5.1 : Layer 2 interconnection options + +Note (not shown in the figure) that an intermediate switch could perform VLAN translation between Transport domain and RAN domain. + +Note that the YANG model caters for all possibilities by defining a set of connectivity parameters per pair of CTI server – CTI client. + +#### 5.1.1.2 Configuration of L2 connectivity parameters + +![Figure 5.2: Configuration of Layer 2 connectivity parameters in case of Ethernet switching. The diagram illustrates the transport domain architecture for CTI servers and clients. It shows the Transport OSS (NMS EMS) and RAN SMO (NMS EMS) interacting with the TN (CTI server) and O-DU (CTI client) via an Ethernet switch. The process involves three steps: 1) MAC address storage in OSS/SMO, 2) MAC address exchange and VLAN ID determination, and 3) MAC address and VLAN ID configuration in the TN and O-DU. A legend defines IP address allocation (Mobile SMO vs. Transport OSS), physical ports, and MAC addresses. It also defines M-plane (M-plane uses IP) and CU-plane (optionally uses IP) connectivity.](52bde0bfbb6eac89939443eebd729795_img.jpg) + +Figure 5.2: Configuration of Layer 2 connectivity parameters in case of Ethernet switching. The diagram illustrates the transport domain architecture for CTI servers and clients. It shows the Transport OSS (NMS EMS) and RAN SMO (NMS EMS) interacting with the TN (CTI server) and O-DU (CTI client) via an Ethernet switch. The process involves three steps: 1) MAC address storage in OSS/SMO, 2) MAC address exchange and VLAN ID determination, and 3) MAC address and VLAN ID configuration in the TN and O-DU. A legend defines IP address allocation (Mobile SMO vs. Transport OSS), physical ports, and MAC addresses. It also defines M-plane (M-plane uses IP) and CU-plane (optionally uses IP) connectivity. + +**Figure 5.2 : Configuration of Layer 2 connectivity parameters in case of Ethernet switching** + +The process involves following steps: + +- 1) [per CTI server] CTI server MAC addr is stored in Transport OSS +[per CTI client] CTI client MAC addr is stored in RAN SMO +- 2) [per CTI server and per CTI client] Transport OSS and RAN SMO exchange CTI server and CTI client MAC addresses from 1), and exchange [per (CTI client;CTI server) combination] the VLAN ID to be used +- 3) [per CTI client] Transport OSS configures MAC addr of CTI clients and VLAN IDs in TN +[per CTI server] RAN SMO configures MAC addr of CTI servers and VLAN IDs in O-DU + +### 5.1.2 IP routing connectivity between TN and O-DU + +#### 5.1.2.1 L2 + L3/L4 Connectivity parameters + +The packets shall follow the UDP/IP/Ethernet encapsulation as described in O-RAN CTI TCP [1]. + +The CTI UDP listening port is invariant but not (yet) defined as a well-known port, so it is also still made configurable. + +Both O-DU and TN need to know the corresponding L2 and L3/L4 parameters to use for communicating with respectively the CTI servers and CTI clients they have to connect to. As mentioned in O-RAN CTI TCP [1], each TN may host multiple CTI servers, each O-DU may host multiple CTI clients, and connectivity between all clients and servers shall be supported. + +At Ethernet level, each CTI client and CTI server may have its own MAC address, and VLANs are used based on the subnetting at IP level. + +At IP level, subnetting defines how many IP addresses are used and how the different nodes will be interconnected; + +- If all CTI servers and clients in the whole network are part of a single subnet (Option A), each client may use single IP address (for communicating with all servers), each server may use a single IP address (for communicating with all clients), and the TNs and O-DUs are connected by point-point links or intermediate switches. +- Alternatively, the network could be split in multiple subnets on a node level, where communication between subnets happen via an intermediate router. Option B shows an example of one subnet at O-DU side and one subnet at TN side, interconnected by an intermediate router. +- Alternatively, the network could be split in multiple subnets along TN-O-DU combinations. Option C shows an example of one subnet per O-DU, shared with all TNs. The CTI servers in the TNs support multiple IP addresses (one per subnet) and there is no need for routing between the TNs and O-DUs (e.g. intermediate switch). + +- (note that sharing subnets across transport and RAN domains (options A and C) probably only apply to cases of a single operator managing both domains). + +At UDP level, a single UDP listening port value is used for all clients, servers and messages. The source port value may be freely chosen. Its value remains the same during a communication session between the CTI client and CTI server, but may be ephemeral from one communication session to the next. + +Note that the YANG model caters for all possibilities by defining a set of connectivity parameters per pair of CTI server – CTI client. + +![Figure 5.3: Layer 3 interconnection options. The diagram illustrates three options (A, B, and C) for connecting Transport Network (TN) servers to Open Distributed Units (O-DUs) via a central network element (Switch or Router). Option A uses a Switch and Option B uses a Router. Each option shows connections between TN A (Server A1 to An) and TN B (Server B1 to Bn) to O-DU X (Client X1 to Xn) and O-DU Y (Client Y1 to Yn). Option A: 1 MAC addr per server, 1 MAC addr per client, 1 VLAN for all, 1 SN for all, 1 IP addr per server, 1 IP addr per client. Option B: 1 MAC addr per server, 1 MAC addr per client, 1 VLAN for TN side, 1 VLAN for O-DU side, 1 IP addr per server, 1 SN for TNs, 1 IP addr per server, 1 SN for O-DUs. Option C: 1 MAC addr per server, 1 MAC addr per client, 1 VLAN per O-DU, 1 SN per O-DU (same for all servers), 1 SN per O-DU (same for all servers), 1 IP addr per server, per O-DU, 1 IP addr per client.](7eb6195a66f16556745601b70664848e_img.jpg) + +**Option A** + +- 1 MAC addr per server +- 1 MAC addr per client +- 1 VLAN for all +- 1 SN for all +- 1 IP addr per server +- 1 IP addr per client + +**Option B** + +- 1 MAC addr per server +- 1 MAC addr per client +- 1 VLAN for TN side +- 1 VLAN for O-DU side +- 1 IP addr per server, 1 SN for TNs +- 1 IP addr per server, 1 SN for O-DUs + +**Option C** + +- 1 MAC addr per server +- 1 MAC addr per client +- 1 VLAN per O-DU +- 1 SN per O-DU (same for all servers) +- 1 SN per O-DU (same for all servers) +- 1 IP addr per server, per O-DU +- 1 IP addr per client + +Figure 5.3: Layer 3 interconnection options. The diagram illustrates three options (A, B, and C) for connecting Transport Network (TN) servers to Open Distributed Units (O-DUs) via a central network element (Switch or Router). Option A uses a Switch and Option B uses a Router. Each option shows connections between TN A (Server A1 to An) and TN B (Server B1 to Bn) to O-DU X (Client X1 to Xn) and O-DU Y (Client Y1 to Yn). Option A: 1 MAC addr per server, 1 MAC addr per client, 1 VLAN for all, 1 SN for all, 1 IP addr per server, 1 IP addr per client. Option B: 1 MAC addr per server, 1 MAC addr per client, 1 VLAN for TN side, 1 VLAN for O-DU side, 1 IP addr per server, 1 SN for TNs, 1 IP addr per server, 1 SN for O-DUs. Option C: 1 MAC addr per server, 1 MAC addr per client, 1 VLAN per O-DU, 1 SN per O-DU (same for all servers), 1 SN per O-DU (same for all servers), 1 IP addr per server, per O-DU, 1 IP addr per client. + +Figure 5.3 : Layer 3 interconnection options + +#### 5.1.2.2 Configuration of L2 connectivity parameters + +O-RAN.WG4.CTI-TMP.0-R003-v04.00 + +Image: O-RAN ALLIANCE Logo + +Image: Figure 5.4 a, b: Configuration of Layer 2 connectivity parameters in case of IP routing + +Detailed description of Figure 5.4: +This figure shows two scenarios (a and b) for configuring Layer 2 connectivity parameters in case of IP routing between Transport domain and RAN domain. +Scenario (a) uses an Ethernet switch in the transport domain. It shows the coordination of VLAN IDs between Transport OSS (NMS/EMS) and RAN SMO (NMS/EMS) (Step 1), and the configuration of VLAN ID for TC-plane on CTI client and CTI server (Step 2). +Scenario (b) uses an IP router in the transport domain. It shows the configuration of VLAN ID for TC-plane on CTI client and CTI server (Step 2) without the coordination step 1 since subnets are not shared. + +Figure 5.4 a, b: Configuration of Layer 2 connectivity parameters in case of IP routing + +The process involves following steps: + +- If subnets are shared between Transport and RAN domains (options A and C in section 5.1.2.1 and Fig 3-2a), the common VLAN IDs shall be coordinated between the Transport OSS and RAN SMO. Otherwise (Option B in section 5.1.2.1 and Fig 3-2b) this step is not needed. +- [per CTI client] Transport OSS configures VLAN ID to be used for TC-plane +[per CTI server] RAN SMO configures VLAN ID to be used for TC-plane + +The MAC addresses of the next hop is fetched by normal means (ARP) after configuration of L3 parameters (see section 5.1.2.3). + +### 5.1.2.3 Configuration of L3 connectivity parameters + +Image: Figure 5.5: Configuration of Layer 3 connectivity parameters in case of IP routing + +Detailed description of Figure 5.5: +This figure shows the configuration of Layer 3 connectivity parameters in case of IP routing. It illustrates the interaction between Transport OSS (with DHCP server and NMS/EMS) and RAN SMO (with NMS/EMS and DHCP server). Steps shown include: 1. Physical connection, 2. DHCP server configuration, 3. Coordination of IP addresses between CTI server and CTI client, and 4. Configuration of IP addresses on CTI client and CTI server. + +Figure 5.5 : Configuration of Layer 3 connectivity parameters in case of IP routing + +© 2023 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. + +13 + +The process involves following steps: + +- 1) [per CTI server] CTI server (in TN) gets L3 configuration, statically or by DHCPv4 or DHCPv6 (or stateless for IPv6) +[per CTI client] CTI client (in O-DU) gets L3 configuration, statically or by DHCPv4 or DHCPv6 (or stateless for IPv6) +- 2) [per CTI server] the assigned CTI server IP address is stored in Transport OSS +[per CTI client] the assigned CTI client IP address is stored in RAN SMO +- 3) [per CTI server and per CTI client] Transport OSS and RAN SMO exchange this information about allocated IP addresses of respectively CTI servers and CTI clients +- 4) [per CTI client] Transport OSS configures IP addr of CTI clients in TN +[per CTI server] RAN SMO configures IP addr of CTI servers in O-DU + +#### 5.1.2.4 Remarks about layer 3 connectivity + +The O-RU and the O-DU need routing table configuration (multiple subnets), this document doesn't describe this configuration. + +Additionally, the DHCP relay agent in the first router facing the O-RU has to be configured with the IP address of the DHCP server in the RAN domain to allow DHCP communication between the DHCP client in the O-RU and the RAN DHCP server. + +In some subnet cases there could be a router between the TN and O-DU. The configuration of the router is not described in this document. + +There could also be a NAT (NAPT) between the TN and O-DU. In that case there are a couple of attention points that need to be considered, namely the impact of destination port translation, the need of NAT traversal, etc... This is out of scope of this document. + +# 6 CTI procedures + +Proper interpretation of CTI messages by the TNs requires a level of cooperation between the CTI server side and CTI client side to guarantee consistency of the parameter values and correlation between the parameters. Although it is possible to rely on manual correlation actions, it is beneficial to automate the process. This section describes an automated autodiscovery method of the correlation of the CTI session IDs with the TU/TN transport parameter they correspond to. The same method can also be used to determine which CTI server has to be associated per given CTI session ID. + +## 6.1 Correlations to be performed + +For proper operation of CTI, several parameters need to be consistent at both TN and at O-DU sides. This means that the same values have to be consistently configured at both CTI server and CTI client side by their respective management systems. The method or protocols for this coordination between Transport OSS and RAN SMO are out of scope of this document. + +Static parameters such as timer values, CTI Flow ID filters, CTI Pattern IDs etc... can be coordinated at OSS level independently of the topology of the O-RUs and transport nodes. + +Dynamically allocated parameters such as IP addresses of CTI servers and CTI clients are dependent of the interconnection topology of TNs and O-DUs, but not of the topology of the O-RUs. They can be coordinated at OSS level. + +The topology of O-RU deployments requires the following correlations for every **CTI session ID**, based which TU interface each O-RU interface is connected to (see Figure 6.1 for a logical view of the correlations. This figure is conceptual only and does not represent how or where the correlation have to be executed (in the TN or in its management system)): + +- The TN needs to determine which transport parameter has to be linked to the corresponding CTI session ID (combined with a CTI flow ID if used) in the CTI report messages (note that multiple transport parameters could be configured on a TU interface, only one pertains to a combination CTI session ID + CTI flow ID). CTI flow IDs are only unique per CTI client (different clients could use the same Flow ID for different meanings), so the CTI client shall be taken into account in the correlation. +- The TN needs also to keep track of which CTI client is reporting the CTI session ID, to send messages related to that CTI session ID. A single CTI client may report about multiple CTI session IDs. +- At O-DU side, the CTI client needs to correlate which CTI session ID to use for each O-RU interface it reports about. This is a one-to-one relationship. For reporting between different flows on the same CTI session ID the O-DU also needs to be aware of the class of service associated to each flow, which in turn is represented by a given set of L2/L3/L4 filter parameters reflecting how uplink traffic is tagged by the O-RU. This tagging could be different in different transport networks (a single O-DU can in principle manage O-RUs in multiple transport networks), so the CTI server (reflecting the TN) shall be taken into account in the correlation. +- The O-DU also needs to know to which CTI server to send the reports for a given CTI session ID. Multiple reports could have to be sent to the same CTI server. + +It is recommended to use the physical MAC address of the O-RU port over which the O-RU has M-plane connectivity as the value of the CTI session ID. + +![Figure 6.1: O-RU topology-dependent correlations for CTI session IDs. The diagram is divided into two parts: 'Correlations in TN' and 'Correlations in O-DU'. In the TN part, a 'CTI session ID' (1) connects to 'TU or TU interface' (1) and 'CTI client' (1). 'TU or TU interface' (1) connects to 'All transport Parameters (T-CONTs or SFs) configured on TU or TU interface' (N). 'CTI client' (1) connects to 'L2 / L3 / L4 filters' (1). 'All transport Parameters' (N) connects to 'Transport Parameter (T-CONT or SF) used for combination CTI session ID, CTI flow ID' (1). 'CTI flow ID' (1) connects to 'L2 / L3 / L4 filters' (1). In the O-DU part, a 'CTI session group' (1) connects to 'CTI session ID' (1) and 'O-RU or O-RU interface' (1). 'CTI session ID' (1) connects to 'CTI server' (1). 'CTI flow ID' (1) connects to 'CTI server' (1). 'CTI server' (1) connects to 'L2 / L3 / L4 filters' (1).](bdadcf4ab22d1254f91aa6359282b10d_img.jpg) + +Figure 6.1: O-RU topology-dependent correlations for CTI session IDs. The diagram is divided into two parts: 'Correlations in TN' and 'Correlations in O-DU'. In the TN part, a 'CTI session ID' (1) connects to 'TU or TU interface' (1) and 'CTI client' (1). 'TU or TU interface' (1) connects to 'All transport Parameters (T-CONTs or SFs) configured on TU or TU interface' (N). 'CTI client' (1) connects to 'L2 / L3 / L4 filters' (1). 'All transport Parameters' (N) connects to 'Transport Parameter (T-CONT or SF) used for combination CTI session ID, CTI flow ID' (1). 'CTI flow ID' (1) connects to 'L2 / L3 / L4 filters' (1). In the O-DU part, a 'CTI session group' (1) connects to 'CTI session ID' (1) and 'O-RU or O-RU interface' (1). 'CTI session ID' (1) connects to 'CTI server' (1). 'CTI flow ID' (1) connects to 'CTI server' (1). 'CTI server' (1) connects to 'L2 / L3 / L4 filters' (1). + +**Figure 6.1 : O-RU topology-dependent correlations for CTI session IDs** +(conceptual only, for YANG elements please see Chapter 6) + +## 6.2 Auto Discovery for correlation of CTI session ID to transport parameter in TN + +This optional method is a means to automate the correlation of CTI session ID with the required transport parameter on the corresponding TU (or TU UNI) on the corresponding TU or TU UNI. It avoids relying on manual correlation during the installation phase of the O-RU to a given TU interface. + +The method is based on re-using the DHCP exchange from the O-RU that is performed during start up of the O-RU to achieve IP connectivity for the M-plane defined in O-RAN MP [4]. Both cases of layer 2 and layer 3 connectivity are very similar, using the DHCP relay agent in the TN to add the agent circuit ID as the key for the correlation. The only differences are the use of giaddr by the DHCP relay agent in case of layer 3 connectivity, and the mandatory use of IP in the C-plane and U-plane traffic in case of layer 3 connectivity. + +If the M-plane uses IPv4, the DHCP relay agent adds Option 82 as per IETF RFC 3046 [11], which contains the agent circuit ID (sub option code 1), which is a string uniquely identifying the TU interface on which the DHCP request was received. + +If the M-plane uses IPv6, the DHCPv6 relay agent adds Option 18 as per IETF RFC 3315 [12], which contains the agent circuit ID. + +Additionally, the possible use of DHCP Option 60 as per IETF RFC 2132 [13] and DHCP Option 124 as per IETF RFC3925 [14] by the O-RU is specified in O-RAN MP [4]. Even if such options are not used, the O-RU interface will be discovered by the RAN SMO during the autoconfiguration of the O-RU through M-plane exchanges. + +Once the O-RU is configured, the RAN SMO can correlate the agent circuit ID with the O-RU interface ID based on the allocated IP address. In turn the O-RU interface is uniquely linked to a CTI session ID. The correlation [agent circuit ID, CTI session ID] can then be notified back to the transport OSS, which pushes the correlation to the corresponding TN that terminates the given TU. + +It is recommended to use the unique MAC address of the O-RU interface as the CTI session ID. For IPv4 this is communicated to the DHCP server in the field “chaddr” of DHCP option 82. For IPv6 it can be communicated as “client link layer address” in DHCPv6 Option 79 as per IETF RFC 6939 [15]. If the O-RU does not use Option 79 in DHCPv6, there needs to be a preconfigured association [O-RU ID; MAC address] in the RAN SMO. + +The auto discovery method applies to cases where the O-RU shares the same physical interface for the M-plane and for the CUS-plane. The method does not apply to O-RUs using different interfaces for the CUS-plane. + +The following sections 6.2.1 and 6.2.2 supersede section 3.2.1.2 in O-RAN CTI TCP [1]. + +### 6.2.1 Switched Ethernet connectivity between O-RU and O-DU + +![Figure 6.2: Auto-discovery method with Layer 2 interconnectivity. The diagram illustrates the network architecture and the sequence of steps for auto-discovery. Key components include: O-RU (with M-plane and CU-plane), TU (Transport Unit), TN (Transport Network) containing a DHCP relay agent and CTI server, Ethernet switch, O-DU (with DHCP server and CTI client), Mobile SMO (Service Management and Orchestration), Transport OSS (Operation and Support System), and NMS/EMS (Network Management System/Element Management System). The legend defines: Blue circle = IP address allocated by Mobile SMO; Green circle = IP address allocated by Transport OSS; Blue rectangle = Physical port; Yellow rectangle = chaddr (MAC address); M = M-plane, CU = CU-plane; m = for node management. The sequence of steps is: 1. O-RU issues DHCP discovery. 2. DHCP relay agent in TN adds option 82. 3. DHCP server in O-DU receives the request. 4. Mobile SMO configures O-DU. 5. Mobile SMO informs Transport OSS. 6. Transport OSS determines the corresponding TN. 7. Transport OSS configures the association. A note states: 'Note: DHCP server either hosted in O-DU or external but part of Mobile network'.](37d9c9813c6708a6f041679c09d1533f_img.jpg) + +Figure 6.2: Auto-discovery method with Layer 2 interconnectivity. The diagram illustrates the network architecture and the sequence of steps for auto-discovery. Key components include: O-RU (with M-plane and CU-plane), TU (Transport Unit), TN (Transport Network) containing a DHCP relay agent and CTI server, Ethernet switch, O-DU (with DHCP server and CTI client), Mobile SMO (Service Management and Orchestration), Transport OSS (Operation and Support System), and NMS/EMS (Network Management System/Element Management System). The legend defines: Blue circle = IP address allocated by Mobile SMO; Green circle = IP address allocated by Transport OSS; Blue rectangle = Physical port; Yellow rectangle = chaddr (MAC address); M = M-plane, CU = CU-plane; m = for node management. The sequence of steps is: 1. O-RU issues DHCP discovery. 2. DHCP relay agent in TN adds option 82. 3. DHCP server in O-DU receives the request. 4. Mobile SMO configures O-DU. 5. Mobile SMO informs Transport OSS. 6. Transport OSS determines the corresponding TN. 7. Transport OSS configures the association. A note states: 'Note: DHCP server either hosted in O-DU or external but part of Mobile network'. + +**Figure 6.2 : Auto-discovery method with Layer 2 interconnectivity** + +The sequence of steps is as follows (example for IPv4); + +- 1) O-RU starts by issuing DHCP discovery for its M-plane communication. The DHCP relay agent in TN adds option 82 to DHCP Discovery. +Note that at start up the O-RU can be unaware of the configured M-plane VLAN ID. It can scan multiple VLAN IDs (and untagged) until receiving an answer from the O-DU side. Only DHCP messages with VLAN ID matching the configured M-plane VLAN ID will be passed through (with option 82 stamped) by the TN, all other messages are discarded by the TN. +- 2) O-RU gets M-plane IP configuration (by DHCP), starts up and gets configured by M-plane: + - Either options 60 or 124 are used that can fully identify O-RU ID + - Or the O-RU ID is discovered during O-RU configuration by the RAN SMO via the M-plane +- 3) Two associations are extracted and stored in the RAN SMO: + - RAN DHCP server extracts the association [assigned M-plane IP address; Agent Circuit ID; chaddr] + - If O-RU ID is present in DHCP options 60 or 124, the RAN domain DHCP server extracts the association [assigned M-plane IP address; O-RU ID]. If the DHCP options 60 or 124 are not used, the association is extracted by RAN SMO. + - If DHCP server is hosted in the O-DU, the information is communicated to the RAN SMO over the O1 interface +- 4) RAN SMO correlates [Agent Circuit ID; chaddr] with [O-RU ID] based on M-plane IP address. +- 5) RAN SMO configures O-DU (via O1) so that CTI client uses CTI session ID = chaddr for this O-RU ID. +- 6) RAN SMO informs Transport OSS with association [Agent Circuit ID; CTI session ID] +- 7) Transport OSS is able to determine the corresponding TN from “Access-Node-Identifier” in Agent Circuit ID, and then configures association (Circuit ID; CTI session ID) to that TN. + +### 6.2.2 IP routing connectivity between O-RU and O-DU + +![Figure 6.3: Auto-discovery method with Layer 3 interconnectivity. The diagram illustrates the network architecture and the sequence of steps for auto-discovery. Key components include: Transport OSS (NMS, EMS), Mobile SMO (DHCP server, NMS, EMS), O-RU (M-plane, CU-plane), TU, TN (DHCP relay agent, CTI server), IP Router, and O-DU (DHCP server, CTI client). The diagram shows the flow of information and the allocation of IP addresses (Mobile OSS, Transport OSS) and physical ports. The sequence of steps is numbered 1 through 7. A legend defines symbols: blue circle for IP address allocated by Mobile OSS, green circle for IP address allocated by Transport OSS, blue rectangle for Physical port, yellow rectangle for chaddr (MAC address), M for M-plane, CU for CU-plane, and m for node management. A note states: 'Note: DHCP server either hosted in O-DU or external but part of Mobile network'.](1bce5115afe14f9c2b1106cbffe790fe_img.jpg) + +Figure 6.3: Auto-discovery method with Layer 3 interconnectivity. The diagram illustrates the network architecture and the sequence of steps for auto-discovery. Key components include: Transport OSS (NMS, EMS), Mobile SMO (DHCP server, NMS, EMS), O-RU (M-plane, CU-plane), TU, TN (DHCP relay agent, CTI server), IP Router, and O-DU (DHCP server, CTI client). The diagram shows the flow of information and the allocation of IP addresses (Mobile OSS, Transport OSS) and physical ports. The sequence of steps is numbered 1 through 7. A legend defines symbols: blue circle for IP address allocated by Mobile OSS, green circle for IP address allocated by Transport OSS, blue rectangle for Physical port, yellow rectangle for chaddr (MAC address), M for M-plane, CU for CU-plane, and m for node management. A note states: 'Note: DHCP server either hosted in O-DU or external but part of Mobile network'. + +Figure 6.3 : Auto-discovery method with Layer 3 interconnectivity + +The sequence of steps is as follows (example for IPv4); + +- 1) O-RU starts by issuing DHCP discovery for its M-plane communication. The DHCP relay agent in TN adds option 82 to DHCP Discovery, adds “giaddr”, converts the message from broadcast to unicast, and forwards it to RAN DHCP server. Note that this requires that the DHCP relay agent in the TN is pre-configured with the IP address of the RAN DHCP server, as mentioned in section 5.1.2.4. Note that at start up the O-RU can be unaware of the configured M-plane VLAN ID (if it is used between TU and TN). The O-RU can scan multiple VLAN IDs (and untagged) until receiving an answer from the O-DU side. The TN will only process DHCP messages with a VLAN ID matching the configured M-plane VLAN ID, all others are discarded by the TN. + +The remaining steps 2 – 7 are identical to the steps in section 6.2.1. + +Note that the same approach can be taken in case the transport domain would be responsible to the IP configuration of the O-RUs (DHCP server hosted in the transport domain). This scenario is not worked out in this document as it is considered to be unlikely. + +## 6.3 Auto discovery for correlation of CTI session ID to CTI server + +There needs to be a pre-configuration at Transport OSS of Agent circuit ID (only the relevant fields) to Server (Server Name and MAC address in case of L2 connectivity for CTI). This association needs to be communicated to the RAN SMO. + +After the auto discovery of 6.2, the RAN SMO knows the Agent circuit ID per O-RU (interface), and the CTI session ID per O-RU (interface). It can then associate the CTI session ID of that O-RU (interface) to its corresponding CTI server based on the TN-identifying portion of the Agent circuit ID. + +## 6.4 Performing correlations without Auto Discovery method + +In this case the correlations are not facilitated by an automated exchange of messages, and involve a manual configuration during installation of each O-RU, and several extra coordination steps between Transport OSS and RAN SMO; + +- 1) the correlation of CTI session ID to O-RU (interface) needs to be done at installation time, by manually populating the association of an O-RU (interface) identifier to a TU (interface) identifier in the Transport OSS. It is then up to the Transport OSS to correlate the O-RU (interface) further to the transport parameter based on the TU (interface) identifier, and if needed to ask for the associated CTI session ID to the RAN SMO (in case the O-RU identifier that is visible to the Transport operator would be another identifier than the CTI session ID). + +- 2) the correlation of CTI session ID to a given CTI server needs an extra level of coordination between the Transport OSS and the RAN SMO. Based on the manual association in step 1), the Transport OSS can deduce the corresponding CTI server for a given CTI session ID based on the TU identifier (which is linked to a given TN user-facing port, which in turn is controlled by a given CTI server). The Transport OSS then communicates the association of CTI session ID (or the O-RU identifier) with the associated CTI Server name (and MAC address in case of L2 connectivity for CTI) to the RAN SMO. + +# 7 CTI Information Model + +## 7.1 General structure of the Information Model + +The model in this document applies to the O-DU. Part of this model is common for the TN, but the specification of the IM of the TN is out of scope of this document. TN considerations (IM and DM) in this document are provided as informational examples. + +This version of the document provides the CTI IM itself and a partial integration of the CTI IM into the broader O-DU IM (see **Figure 7.6**). The full integration into the broader O-DU IM (choice of IOC as attachment point for CTIConfig IOC) is subject to further study and optimization in a future version of the document. + +The logical structure of the CTI IM at O-DU is determined by following facts; + +- When an O-DU supports the optional CTI functionality, it may have one or multiple CTI clients. Each O-DU has a separate “CTI Function” IOC, that contains one or multiple CTI clients. Each CTI client has a separate IOC “CTIClient” that shall be configured. +- For each O-DU, the possible CTI server(s) that its CTI client(s) connect to shall be represented by a MOI “CTIServer”. +- In one O-DU, each CTI client may have connectivity to multiple remote CTI servers, and each such CTI server may have connectivity to multiple CTI clients in the O-DU (in other words a full mesh of CTI servers and CTI clients is supported). +- Each pair of CTI server and CTI client shall use a “CTIConnProfile” for the exchange of CTI messages between the pair. A CTIConnProfile may be used by multiple server-client pairs. +- CTISessions of a given CTI client are grouped per corresponding CTI Server into a “CTISessionGroup”. +- CTIFlow(s) are configured per CTI server and e be referred by “CTIFlowsInUse” in one or multiple CTI sessions (of one or multiple CTI clients). +- “CTISession” for each CTIClient and “CTIFlowsInUse” for each CTISession shall also be configured before the CTI functionality starts to work. +- There are network-wide definitions of CTI patterns. The same pattern has the same meaning for all CTI servers and CTI clients. + +Depending on its position in the YANG structure, a parameter may be unique for the whole node, or only within a smaller context in the node allowing for multiple values to be configured inside the same node. Additionally, if a parameter needs to be unique across the whole network, this consistency shall be assured by the SMO system to configure the same value in all its managed nodes. + +### CTI Session ID: + +The CTI Session ID shall be unique across the whole network. Recommendation is to use the MAC address of the O-RU interface it is linked to. + +The CTI session ID element is used as the cornerstone in the TN and O-DU YANG models. + +### CTI Session Group: + +In each CTI Client the CTI sessions are regrouped per associated CTI Server. + +### O-RU ID or O-RU interface ID: + +They are used locally in the O-DU, so in principle only unique within one O-DU. But it is more practical if it is unique across the whole network. + +They are not used in the TN. + +### Filter values linked to a CTI Flow ID: + +From O-DU point of view a Flow ID may either represent the same filter values over the whole network (all TNs), or the same ID could represent different filter values in different transport networks (eg if TNs in different transport networks use different VLAN tagging). Therefore the CTI Flow ID is defined at per-CTI server level in the O-DU. + +From the TN point of view a Flow ID may either represent the same filter values over the whole network (all O-DUs), or the same ID could represent different filter values in different RAN networks, eg if the same ID would be re-used by accident by two different RAN networks (sets of O-DUs). Therefore the CTI Flow ID is defined at per-CTI client level in the TN. + +### Pattern characteristics linked to a CTI Pattern ID: + +From O-DU point of view a Pattern ID shall represent the same pattern characteristics no matter on which TN an O-RU is connected to. The Pattern ID may therefore be unique at O-DU node level. It is up to the RAN SMO to configure consistent values across the different O-DUs. + +From TN point of view a same Pattern ID could be re-used by accident by two different RAN networks (sets of O-DUs) while representing different pattern characteristics. The CTI Pattern ID is therefore defined at a per-CTI client level in the TN, allowing to make such differentiation. + +### L2, L3, L4 Parameters for CTI connectivity: + +As mentioned in section 5.1, different sorts of connectivity may be used between pairs of clients and servers. The use of L2, L3 and L4 parameters are part of the network-wide planning. + +In the O-DU the parameters are kept in the CTI Client, CTI Server, and CTI connectivity profile. The CTI client keeps its MAC address (in case of Ethernet connectivity). The CTI Server keeps its connectivity type, its MAC address (in case of Ethernet connectivity) or its host (in case of UDP/IP connectivity). The CTI connectivity profile may be used between one or multiple pairs of CTI Client and CTI Server and keeps its connectivity type, the VLAN tag in case of Ethernet connectivity or the VLAN tag in case of UDP/IP connectivity, and the client host (in case of UDP/IP connectivity). + +A similar approach could be taken in the TN to group connectivity parameters per pair of CTI server and CTI client, see Annex B for an example. + +There is no distinction between message types (all messages between a CTI client and CTI server shall use the same connectivity parameters). + +### CTI timers + +It is assumed that there is no difference in timer values throughout the network, their values shall be unique. + +#### UDP listening port + +When UDP/IP is used for CTI transport between a CTI client and a CTI server, all messages between all CTI servers and all CTI clients over all networks shall use the same destination port value. Without a well-known IANA port, a single value shall be consistently configured in all TN and O-DU nodes. + +### CTI versions + +Each TN could support one or more versions, each O-DU may support one or more versions. The supported versions are a list structure in the O-DU and in the TN. Each CTI client shall know what versions are supported by a given CTI server, and vice versa. Hence the CTI version to be used is defined per CTI client in the TN, per CTI server in the O-DU. + +Please note there is no direct version negotiation mechanism in CTI between a CTI client and a CTI server, it is up to the management to select the appropriate version to be used. + +### Ethertype and Protocol subtype values when CTI directly encapsulated in L2 + +The values for the O-RAN EtherType and CTI Protocol Subtype are invariant over all networks. + +## 7.2 Relationships and unicities in the context of encapsulation of CTI flows between CTI servers and CTI clients + +The attributes needed to determine the CTI encapsulation for the CTI sessions contained in one CTI session group are included in the related CTI client, CTI server, and CTI connectivity profile IOCs. + +![Figure 7.1: Connectivity example of single Connectivity profile per (client, server) pair (eg UDP/IP). The diagram shows two TNs (CTI server 10 and CTI server 12) connected to an O-DU. Each TN has a connectivity profile (X, Y, Z) pointing to specific CTI session groups (1a, 2a, 2b) within CTI clients (Client 1, Client 2). These session groups are then mapped to CTI servers (Server 10, Server 12) via connectivity profiles (X, Y, Z).](e44a0bb164141faab1727fe3b24cad0c_img.jpg) + +Can be same TN or separate TNs + +CTI server 10 + +CTI server 12 + +Conn profile X CTI server 10 + +Conn profile Y CTI server 10 + +Conn profile Z CTI server 12 + +O-DU + +CTI client "Client 1" + +CTI session group "1a" + +CTI session "A" + +CTI session "B" + +CTI client "Client 2" + +CTI session group "2a" + +CTI session "C" + +CTI session group "2b" + +CTI session "D" + +CTI server "Server 10" + +CTI server "Server 12" + +Connectivity type = UDP/IP CTI server 10 host + +Connectivity type = UDP/IP CTI server 12 host + +Connectivity type = UDP/IP VLAN tag X CTI client 1 host + +Connectivity type = UDP/IP VLAN tag Y CTI client 2 host + +Connectivity type = UDP/IP VLAN tag Z CTI client 2 host + +There can be 0, 1 or any number of IOCs pointing to this single IOC instance + +Configured attribute(s) + +IOC + +Unique values (a value can not be re-used for a different instance in the O-DU or in other O-DUs) + +Unique values within O-DU (a value can be re-used in other O-DUs) + +Figure 7.1: Connectivity example of single Connectivity profile per (client, server) pair (eg UDP/IP). The diagram shows two TNs (CTI server 10 and CTI server 12) connected to an O-DU. Each TN has a connectivity profile (X, Y, Z) pointing to specific CTI session groups (1a, 2a, 2b) within CTI clients (Client 1, Client 2). These session groups are then mapped to CTI servers (Server 10, Server 12) via connectivity profiles (X, Y, Z). + +**Figure 7.1 : Connectivity example of single Connectivity profile per (client, server) pair (eg UDP/IP)** + +![Figure 7.2: Connectivity example of multiple (client, server) pairs in single Connectivity profile (eg Ethernet with 1 VLAN per TN). The diagram shows two TNs (CTI server 10 and CTI server 12) connected to an O-DU. Each TN has a connectivity profile (X, Y, Z) pointing to specific CTI session groups (1a, 2a, 2b) within CTI clients (Client 1, Client 2). These session groups are then mapped to CTI servers (Server 10, Server 12) via connectivity profiles (X, Y, Z).](bb82b02cd9670b140a2f7d1e1fa563ca_img.jpg) + +Can be same TN or separate TNs + +CTI server 10 + +CTI server 12 + +Conn profile X CTI server 10 + +Conn profile X CTI server 10 + +Conn profile Z CTI server 12 + +O-DU + +CTI client 10 MAC addr + +CTI client "Client 1" + +CTI session group "1a" + +CTI session "A" + +CTI session "B" + +CTI client 12 MAC addr + +CTI client "Client 2" + +CTI session group "2a" + +CTI session "C" + +CTI session group "2b" + +CTI session "D" + +CTI server "Server 10" + +CTI server "Server 12" + +Connectivity type = ethernet CTI server 10 MAC addr + +Connectivity type = ethernet CTI server 12 MAC addr + +Connectivity type = ethernet VLAN tag X + +Connectivity type = ethernet VLAN tag Z + +There can be 0, 1 or any number of IOCs pointing to this single IOC instance + +Configured attribute(s) + +IOC + +Unique values (a value can not be re-used for a different instance in the O-DU or in other O-DUs) + +Unique values within O-DU (a value can be re-used in other O-DUs) + +Figure 7.2: Connectivity example of multiple (client, server) pairs in single Connectivity profile (eg Ethernet with 1 VLAN per TN). The diagram shows two TNs (CTI server 10 and CTI server 12) connected to an O-DU. Each TN has a connectivity profile (X, Y, Z) pointing to specific CTI session groups (1a, 2a, 2b) within CTI clients (Client 1, Client 2). These session groups are then mapped to CTI servers (Server 10, Server 12) via connectivity profiles (X, Y, Z). + +**Figure 7.2 : Connectivity example of multiple (client, server) pairs in single Connectivity profile (eg Ethernet with 1 VLAN per TN)** + +![Figure 7.3: Connectivity example of multiple (client, server) pairs in single Connectivity profile. The diagram shows two TNs (CTI server 10 and CTI server 12) connected to an O-DU. The O-DU contains CTI client groups (1a, 2a, 2b) and CTI sessions (A, B, C, D). These are mapped to CTI servers (Server 10, Server 12) via connectivity profiles X, Y, and Z. Profile X is Ethernet, while Y and Z are UDP/IP. A legend explains IOC multiplicity and uniqueness.](8fae5b0fa08809d3828149e3aff278b9_img.jpg) + +Can be same TN or separate TNs + +CTI client 10 MAC addr + +CTI client "Client 1" + +CTI session group "1a" + +CTI session "A" + +CTI session "B" + +CTI client 12 MAC addr + +CTI client "Client 2" + +CTI session group "2a" + +CTI session "C" + +CTI session group "2b" + +CTI session "D" + +Conn profile X CTI server 10 + +Conn profile X CTI server 10 + +Conn profile Z CTI server 12 + +Conn profile X CTI server 12 + +Connectivity type = ethernet CTI server 10 MAC addr + +CTI server "Server 10" + +CTI server "Server 12" + +Connectivity type = UDP/IP CTI server 12 host + +Connectivity profile "X" + +Connectivity type = ethernet VLAN tag X + +Connectivity profile "Z" + +Connectivity type = UDP/IP VLAN tag Z CTI client 2 host + +There can be 0, 1 or any number of IOCs pointing to this single IOC instance + +Configured attribute(s) + +IOC + +Unique values (a value can not be re-used for a different instance in the O-DU or in other O-DUs) + +Unique values within O-DU (a value can be re-used in other O-DUs) + +Figure 7.3: Connectivity example of multiple (client, server) pairs in single Connectivity profile. The diagram shows two TNs (CTI server 10 and CTI server 12) connected to an O-DU. The O-DU contains CTI client groups (1a, 2a, 2b) and CTI sessions (A, B, C, D). These are mapped to CTI servers (Server 10, Server 12) via connectivity profiles X, Y, and Z. Profile X is Ethernet, while Y and Z are UDP/IP. A legend explains IOC multiplicity and uniqueness. + +**Figure 7.3 : Connectivity example of multiple (client, server) pairs in single Connectivity profile (eg Ethernet for some servers, UDP/IP for other servers)** + +![Figure 7.4: Connectivity example of multiple (client, server) pairs in single Connectivity profile (eg Ethernet with same VLAN for all TNs). This diagram is similar to Figure 7.3 but shows all connectivity profiles (X, Y, Z) as Ethernet with the same VLAN tag. The O-DU structure and session mappings are identical to Figure 7.3.](646622819b5259c1e7e4374e0e5698b1_img.jpg) + +Can be same TN or separate TNs + +CTI client 10 MAC addr + +CTI client "Client 1" + +CTI session group "1a" + +CTI session "A" + +CTI session "B" + +CTI client 12 MAC addr + +CTI client "Client 2" + +CTI session group "2a" + +CTI session "C" + +CTI session group "2b" + +CTI session "D" + +Conn profile X CTI server 10 + +Conn profile X CTI server 10 + +Conn profile X CTI server 12 + +Conn profile X CTI server 12 + +Connectivity type = ethernet CTI server 10 MAC addr + +CTI server "Server 10" + +CTI server "Server 12" + +Connectivity type = ethernet CTI server 12 MAC addr + +Connectivity profile "X" + +Connectivity type = ethernet VLAN tag X + +There can be 0, 1 or any number of IOCs pointing to this single IOC instance + +Configured attribute(s) + +IOC + +Unique values (a value can not be re-used for a different instance in the O-DU or in other O-DUs) + +Unique values within O-DU (a value can be re-used in other O-DUs) + +Figure 7.4: Connectivity example of multiple (client, server) pairs in single Connectivity profile (eg Ethernet with same VLAN for all TNs). This diagram is similar to Figure 7.3 but shows all connectivity profiles (X, Y, Z) as Ethernet with the same VLAN tag. The O-DU structure and session mappings are identical to Figure 7.3. + +**Figure 7.4 : Connectivity example of multiple (client, server) pairs in single Connectivity profile (eg Ethernet with same VLAN for all TNs)** + +## 7.3 Relationships and unicities in the context of CTI sessions, CTI flows, CTI Patterns + +The attributes needed to determine the identification fields in the CTI report (session ID, flow ID and pattern ID) for a given session are included in the related CTI session, CTI server, and CTI pattern IOCs. + +A CTI pattern may be included in CTI messages associated to any CTI flow of any CTI session without the need for explicit configuration per CTI flow or CTI session. This CTI message field is assumed to be generated by the CTI client on the fly just like other dynamic variable fields (bandwidth, time, etc.). Therefore the CTI session IOC is not represented as a pointer in other IOCs. + +![Figure 7.5: example with multiple CTI sessions, CTI flows, CTI Patterns. The diagram illustrates the architecture of CTI (Control Traffic Interception) in an O-DU (Open Distributed Unit). It shows two TNs (Networks) connected to O-DU. TN 1 contains CTI server 10 with filter settings for CTI Flow ID = 1, 2, and 14. TN 2 contains CTI server 12 with filter settings for CTI Flow ID = 7 and 14. The O-DU contains two CTI clients: 'Client 1' and 'Client 2'. 'Client 1' has two session groups: '1a' and '1b'. 'Client 2' has two session groups: '2a' and '2b'. Each session group contains multiple CTI sessions (A, B, C, D) and their respective CTI flows. The diagram also shows CTI servers 'Server 10' and 'Server 12' with their respective CTI flows and filters. CTI patterns '3' and '22' are also shown. The diagram includes a legend for IOC (Information Object Class) and a note about the use of IOC instances in CTI messages.](5f7caf91d90782b98b1427d9ad734df8_img.jpg) + +Can be same TN or separate TNs + +Use of this IOC instance in CTI messages for given CTI session/CTI flow + +There can be 0, 1 or any number of IOCs pointing to this single IOC instance + +Configured attribute(s) + +Identical values to be configured in whole network (i.e. same value represents same meaning in all CTI clients and CTI servers) + +Unique values (a value can not be re-used for a different instance in the O-DU or in other O-DUs) + +Unique values within a CTI server (a value can be re-used in another CTI server) + +Figure 7.5: example with multiple CTI sessions, CTI flows, CTI Patterns. The diagram illustrates the architecture of CTI (Control Traffic Interception) in an O-DU (Open Distributed Unit). It shows two TNs (Networks) connected to O-DU. TN 1 contains CTI server 10 with filter settings for CTI Flow ID = 1, 2, and 14. TN 2 contains CTI server 12 with filter settings for CTI Flow ID = 7 and 14. The O-DU contains two CTI clients: 'Client 1' and 'Client 2'. 'Client 1' has two session groups: '1a' and '1b'. 'Client 2' has two session groups: '2a' and '2b'. Each session group contains multiple CTI sessions (A, B, C, D) and their respective CTI flows. The diagram also shows CTI servers 'Server 10' and 'Server 12' with their respective CTI flows and filters. CTI patterns '3' and '22' are also shown. The diagram includes a legend for IOC (Information Object Class) and a note about the use of IOC instances in CTI messages. + +Figure 7.5 : example with multiple CTI sessions, CTI flows, CTI Patterns + +## 7.4 CTI IM for O-DU + +### 7.4.1 Imported and associated information + +Table 7.1: imported and associated information + +| Label reference | Local label | +|--------------------------------------|----------------| +| 3GPP TS 28.622 , IOC, ManagedElement | ManagedElement | +| 3GPP TS 28.622 , IOC, Top | Top | + +### 7.4.2 Relationships at O-DU CTI Client + +``` + +@startuml +Class ManagedElement <<InformationObjectClass>> +Class GNBDUFunction <<InformationObjectClass>> +Class CTIFunction <<InformationObjectClass>> +Class CTIConfig <<DataType>> +Class CTIClient <<InformationObjectClass>> +Class CTIServer <<DataType>> +Class CTIFlow <<DataType>> +Class CTIConnProfile <<DataType>> +Class CTISessionGroup <<DataType>> +Class CTISession <<DataType>> +Class CTIFlowsInUse <<DataType>> +Class CTIPattern <<DataType>> +Class L2Filter <<DataType>> +Class L3and4Filter <<DataType>> +Class CTIClientServerStatus <<DataType>> + +ManagedElement *-- "*" GNBDUFunction: <<names>> +GNBDUFunction *-- "0..*" CTIFunction: <<names>> +CTIFunction *-- "0..*" CTIClient: <<names>> +CTIFunction *--> "0..*" CTIPattern + +``` + +``` + +1 CTIFunction *--> "0..*" CTIConnProfile +2 CTIFunction *--> "0..*" CTIServer +3 +4 CTIClient *--> "0..*" CTISessionGroup +5 CTIClient *--> "0..*" CTIConfig +6 CTIClient *--> "0..*" CTIClientServerStatus +7 +8 CTIClientServerStatus --> "0..*" CTIServer +9 +10 CTIServer *--> "0..*" CTIFlow +11 +12 CTIFlow *--> "0..*" L2Filter +13 CTIFlow *--> "0..*" L3and4Filter +14 +15 CTISessionGroup *--> "0..*" CTISession +16 CTISessionGroup "0..*" --> "1" CTIServer +17 CTISessionGroup "0..*" --> "1" CTIConnProfile +18 +19 CTISession *--> "0..*" CTIFlowsInUse +20 +21 CTIFlowsInUse "0..*" --> "1" CTIFlow +22 +23 @enduml + +``` + + + +### 7.4.3 Inheritance + +``` + +@startuml +Abstract class TOP +/' general class '/ + +Class CTIFunction <<InformationObjectClass >> +Class CTIClient <<InformationObjectClass >> + +TOP<|-- CTIFunction +TOP<|-- CTIClient + +@enduml + +``` + +![UML class diagram showing inheritance. A class box labeled 'TOP' with a blue circle containing 'A' is at the top. Below it are two class boxes: 'CTIFunction' and 'CTIClient', both labeled '<<InformationObjectClass>>' and containing a green circle with 'C'. Arrows point from 'CTIFunction' and 'CTIClient' up to 'TOP', indicating inheritance.](2c8e1715dc65759daa895a3d291d05a0_img.jpg) + +UML class diagram showing inheritance. A class box labeled 'TOP' with a blue circle containing 'A' is at the top. Below it are two class boxes: 'CTIFunction' and 'CTIClient', both labeled '<>' and containing a green circle with 'C'. Arrows point from 'CTIFunction' and 'CTIClient' up to 'TOP', indicating inheritance. + +Figure 7.7 : Inheritance in CTI IM + +### 7.4.4 Class and Type definitions + +#### 7.4.4.1 CTIFunction <<InformationObjectClass>> + +This IOC represents the root level of CTI client configuration. + +##### Rules for configuration: + +Each O-DU GNBDUFunction that supports CTI has at least one CTIFunction instance. + +Table 7.2: CTIFunction IOC + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|---------------------|-------------------|------------|------------|-------------|--------------| +| ctiActivateOnOdu | M | T | T | F | T | +| ctiPattern (DT) | M | T | T | F | T | +| ctiServer (DT) | M | T | T | F | T | +| ctiConnProfile (DT) | M | T | T | F | T | + +#### 7.4.4.2 CTIClient <<InformationObjectClass>> + +This IOC represents per-CTI client-wide characteristics (one O-DU may have multiple CTI clients) valid for all its CTI sessions. + +##### Rules for configuration: + +One CTI client could have different connectivity types to different CTI servers. + +- Whenever the CTI client has at least one Ethernet connectivity with some CTI server, the CTI client MAC address shall be configured, otherwise the client can't be linked to a physical interface on the O-DU and the CTI connectivity wouldn't not work. +- If all CTI connectivities of the CTI client are based on UDP/IP, it is assumed the client hostname (see "CTIconnProfile" DT) shall be sufficient to deduce the physical interface on the O-DU, and the CTI client MAC address does not need to be configured. +- One CTI client may communicate to multiple CTI Servers. For each [CTI client, CTI server] pair it is independently possible to activate or deactivate the exchange of CTI messages. + +Table 7.3: CTIClient IOC + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|----------------------------|-------------------|------------|------------|-------------|--------------| +| ctiClientInfo | M | T | T | F | T | +| ctiClientMacAddr | M | T | T | F | T | +| ctiClientServerStatus (DT) | M | T | T | F | T | +| ctiConfig (DT) | M | T | T | F | T | +| ctiSessionGroup (DT) | M | T | T | F | T | + +#### 7.4.4.3 CTIClientServerStatus <<DataType>> + +This DT groups attributes that describe the status of the exchange of CTI messages between a given CTI Client and a given CTI Server. + +##### Rules for configuration: + +Each CTIClientServerStatus instance describes one pair of CTI Client – CTI Server, hence refers to only one CTI Server. There shall be one instance for each Server that this Client communicates with. + +##### Monitoring: + +The ctiClientServerConnStatus reflects the status of the CTI keep-alive exchange between the client and a given server and is read-only. "True" signifies that the keepalives are received as expected from the given server. "False" signifies that keepalives from the given server have been not been received for longer than the time out duration (ctiTo). + +Table 7.4: CTIClientServerStatus DT + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|---------------------------|-------------------|------------|------------|-------------|--------------| +| ctiClientServerActivate | M | T | T | F | T | +| ctiClientServerConnStatus | M | T | F | F | T | +| ctiServerRef | M | T | T | F | T | + +#### 7.4.4.4 CTIConfig <<DataType>> + +This DT groups generic CTI client configuration attributes. + +##### Rules for configuration: + +At least one of attributes "subtype" (if CTI is transported over Ethernet) and "UDP port" (if CTI is transported over UDP/IP over Ethernet) shall be configured: + +\* subtype shall be configured if there is any Layer 2 CTI connectivity of the considered CTI client to some CTI server. If there is no such Layer 2 CTI connectivity it does not need to be configured. + +\* UDP port shall be configured if there is any UDP/IP CTI connectivity of the considered CTI client to some CTI server. If there is no such UDP/IP CTI connectivity it does not need to be configured. + +Both shall be configured when different CTI servers use different encapsulations. + +**Table 7.5: CTIConfig DT** + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|-----------------------------|-------------------|------------|------------|-------------|--------------| +| ctiReportRateCategory | M | T | F | F | T | +| ctiMessageTimingPerformance | M | T | F | F | T | +| supportedCtiVersions | M | T | F | F | T | +| minNotificationAdvanceTime | O | T | F | F | T | +| ctiKa | M | T | T | F | T | +| ctiTo | M | T | T | F | T | +| protocolSubtype | M | T | T | F | T | +| ctiListeningUdpPort | M | T | T | F | T | + +#### 7.4.4.5 CTISessionGroup <<DataType>> + +This DT regroups all (one or multiple) CTI sessions of the parent CTI Client per corresponding CTI Server (in one TN). In other words there is one CTI Session group per [CTI client, CTI server] pair. See figures 1,2A,2B,3. + +##### Rules for configuration: + +Each CTISessionGroup refers to one CTIServer and to one CTIConnProfile. One CTIConnProfile shall be referred from multiple CTISessionGroups. + +During configuration, when adding a CTI session to a CTI session group it shall be verified that the CTI session pertains to the CTI server associated with the CTI session group. + +During configuration, connection type of CTIServer and CTIConnProfile that are referred to by the CTISessionGroup shall be the same (see configuration rule at CTIConnProfile). + +**Table 7.6: CTISessionGroup DT** + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|-------------------|-------------------|------------|------------|-------------|--------------| +| ctiServerRef | M | T | T | F | T | +| ctiConnProfileRef | M | T | T | F | T | +| ctiSession (DT) | M | T | T | F | T | + +#### 7.4.4.6 CTISession <<DataType>> + +This DT represents per-CTI session-specific characteristics (a session runs between a given CTI client and a given CTI server). + +##### Rules for configuration: + +The CTI session ID used in the CTI messages e be configurable while being globally unique in the network. The recommended type for identifying the CTIsession by its ID is the MAC address of the corresponding O-RU interface. + +The CTI session ID may either represent an O-RU or an O-RU interface. The corresponding attribute (O-RU ID or O-RU interface ID) shall be configured. The unicity of CTI session ID per O-RU ID or per O-RU interface ID shall be checked in the O-DU (across the O-DU). + +The CTI session ID attribute is linked to an O-RU (or O-RU interface) and should be Invariant (any new O-RU should be configured as a new instance of the DT, not as a change of an existing instance). The enforcement of the Invariant nature shall be provided by the application level. + +**Table 7.7: CTISession DT** + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|---------------------------------|-------------------|------------|------------|-------------|--------------| +| ctiSessionId | M | T | T | T | T | +| oRuId | M | T | T | F | T | +| oRuInterfaceId | M | T | T | F | T | +| ctiNominalReportMsgInterval | M | T | T | F | T | +| ctiReportMessagingUseOfType1Ext | M | T | T | F | T | +| ctiFlowsInUse (DT) | M | T | T | F | T | + +#### 7.4.4.7 CTIServer <<DataType>> + +This DT represents per-CTI server characteristics (one O-DU may interact with multiple CTI servers on multiple TNs) . + +##### Rules for configuration: + +Server information may be chosen freely by operator (string). + +If connectivity type to this CTI Server is set to “Ethernet”, then the CTI Server MAC address shall be configured. + +If connectivity type is set to “UDPIP”, then CTI Server host shall be configured. In that case the MAC address of the next hop should be obtained by ARP and there is no need to configure the CTI Server MAC address. + +The DOCSIS Server Info is not currently defined and only mentioned as optional placeholder. It is an optional attribute. + +The CTI Server MAC address attribute is linked to an O-DU instance and should be Invariant (any new CTI Server should be configured as a new instance of the DT, not as a change of an existing instance). The enforcement of the Invariant nature shall be provided by the application level. + +**Table 7.8: CTIServer DT** + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|---------------------------------------------|-------------------|------------|------------|-------------|--------------| +| ctiServerId | M | T | T | F | T | +| ctiServerInfo | M | T | T | F | T | +| connectivityType | M | T | T | F | T | +| ctiServerMacAddr | M | T | T | T | T | +| ctiServerHost | M | T | T | F | T | +| ctiEnable | M | T | T | F | T | +| supportedCtiVersions | M | T | T | F | T | +| ctiReportMessagingUseOfType2 | M | T | T | F | T | +| ponServerInfoUseNotificationsFromThisServer | M | T | T | F | T | +| docsisServerInfo | O | T | T | F | T | +| ctiFlow (DT) | M | T | T | F | T | + +#### 7.4.4.8 CTIFlow <<DataType>> + +This DT represents per-CTI flow characteristics as defined on a given CTI server, and shall be used by one or multiple CTI sessions with that CTI server. + +##### Rules for configuration: + +If filter type is set to “Ethernet”, then the configuration of Layer2Filter shall be used. If this configuration is missing, the function does not work (the CTI client does not know which Flow ID to use in the CTI messages for a given fronthaul flow with these Layer 2 characteristics). + +If filter type is set to “UDPIP”, then the configuration of Layer3and4Filter shall be used. If this configuration is missing, the function does not work (the CTI client does not know which Flow ID to use in the CTI messages for a given fronthaul flow with these Layer 3 / Layer 4 characteristics). + +**Table 7.9: CTIFlow DT** + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|-----------------------|-------------------|------------|------------|-------------|--------------| +| ctiFlowId | M | T | T | F | T | +| filterType | M | T | T | F | T | +| layer2Filter (DT) | M | T | T | F | T | +| layer3and4Filter (DT) | M | T | T | F | T | + +#### 7.4.4.9 Layer2Filter <<DataType>> + +This DT represents a set of Ethernet-level traffic filter parameters in a given CTI server, to be associated to a CTI flow. + +##### Rules for configuration: + +A Layer 2 Filter consists of a set of one or more attributes. Each attribute that is configured is considered in the filter. At least one attribute e be configured. + +**Table 7.10: Layer2Filter DT** + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|-----------------|-------------------|------------|------------|-------------|--------------| +| source-mac | M | T | T | F | T | +| destination-mac | M | T | T | F | T | +| ethertype | M | T | T | F | T | +| pcp | M | T | T | F | T | +| vlan-id | M | T | T | F | T | + +#### 7.4.4.10 Layer3and4Filter <<DataType>> + +This DT represents a set of UDP/TCP and IP-level traffic filter parameters in a given CTI server, to be associated to a CTI flow. + +##### Rules for configuration: + +A Layer 3 and Layer 4 Filter consists of a set of one or more attributes. Each attribute that is configured is considered in the filter. At least one attribute e be configured. + +**Table 7.11: Layer3and4Filter DT** + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|------------------------|-------------------|------------|------------|-------------|--------------| +| source-address | M | T | T | F | T | +| source-prefix | M | T | T | F | T | +| destination-address | M | T | T | F | T | +| destination-prefix | M | T | T | F | T | +| dscp | M | T | T | F | T | +| source-port-start | M | T | T | F | T | +| source-port-end | M | T | T | F | T | +| desintation-port-start | M | T | T | F | T | +| destination-port-end | M | T | T | F | T | +| ipv4-protocol | M | T | T | F | T | +| ipv6-traffic-class | M | T | T | F | T | +| ipv6-flow | M | T | T | F | T | +| ipv6-next-header | M | T | T | F | T | + +#### 7.4.4.11 CTIFlowsInUse <<DataType>> + +This DT represents the characteristics of each CTI flow that is used in a given CTI session (between a given CTI client and a given CTI server). + +##### Rules for configuration: + +If flow differentiation is used inside a given CTI session (each flow is associated with a given L2 or L3/L4 filter), each flow in use needs configuration of the associated attributes listed below, including a reference to the corresponding CTI flow (ctiFlowRef). + +If there is no differentiation between flows in a given CTI session (and hence no filtering), there is only one flow and all corresponding CTI messages shall carry “0x00” as the flow ID value. There is still a need to configure the associated attributes listed below, except that there is no need to reference a specific CTI flow (no need to configure ctiFlowRef). + +Table 7.12: CTIFlowsInUse DT + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|-----------------------|-------------------|------------|------------|-------------|--------------| +| timeIntervalPerReport | M | T | T | F | T | +| maxT34Latency | M | T | T | F | T | +| minLoad | M | T | T | F | T | +| extraLoadCplane | M | T | T | F | T | +| ctiFlowRef | M | T | T | F | T | + +#### 7.4.4.12 CTIConnProfile <<DataType>> + +This DT represents a group of encapsulation parameters for exchange of CTI messages between a given CTI client on the O-DU and a given CTI server on a TN. + +All CTI messages between a given CTI client and a given CTI server shall always use the same encapsulation values. But a given CTI client may use different encapsulations for different CTI servers. This is why the VLAN tag and client local IP addr are defined at level of CTIConnProfile DT and not at level of CTIClient IOC. The MAC address of the CTI client on the other hand is assumed to be unique for all its connectivities, and is defined at the level of CTIClient IOC. + +##### Rules for configuration: + +The connectivity type of a given CTIConnProfile instance shall match the connectivity type of the CTI server to which the CTI session group using the CTIConnProfile is associated with. This requires a check during configuration of the CTISessionGroup; + +Step 1; CTIConnProfile is created + +Step 2; CTI Session Group is created and refers to a given CTI server and to the CTIConnProfile. Validation is needed to ensure that the connectivity type of the CTIConnProfile matches the connectivity type of the CTI Server referred by the CTI Session Group. If it doesn't match, this CTI Session Group cannot be created. + +If connectivity type is set to "Ethernet", then the connectivity shall use VLAN Tag for L2. If that attribute is not configured, the connectivity does not work. + +If connectivity type is set to "UDPIP", then the connectivity shall use VLAN Tag for L3 and L4, and CTI client host. If these attributes are not configured, the connectivity does not work. + +Table 7.13: CTIConnProfile DT + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|------------------|-------------------|------------|------------|-------------|--------------| +| ctiConnProfileId | M | T | T | F | T | +| connectivityType | M | T | T | F | T | +| vlanTagForL2 | M | T | T | F | T | +| vlanTagForL3and4 | M | T | T | F | T | +| ctiClientHost | M | T | T | F | T | + +#### 7.4.4.13 CTIPattern <<DataType>> + +This DT represents the characteristics of a given pattern ID. They are valid O-DU-system wide. + +##### Rules for configuration: + +The pattern ID is an integer number (up to 32 bits). If the pattern reflects a well-known TDD symbol sequence, it is recommended to include the 3GPP slot format number in the ID (see 3GPP TS38.213 Table 11.1.1-1). + +The same Pattern ID shall represent the same content in any CTI client of any O-DU in the network. + +In case there is no use of TDD pattern information, the CTI messages shall carry the Pattern ID value 0 and there is no need to configure the CTIPattern class. + +**Table 7.14: CTIPattern DT** + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|------------------------|-------------------|------------|------------|-------------|--------------| +| patternId | M | T | T | F | T | +| patternDuration | M | T | T | F | T | +| patternEvents | M | T | T | F | T | +| patternEventMultiplier | M | T | T | F | T | +| patternEventBytes | M | T | T | F | T | +| patternNormalization | M | T | T | F | T | + +### 7.4.5 Attribute definitions + +**Table 7.15: Attributes definition** + +| Attribute Name | Documentation and Values<br>(format & unit, allowed values, reserved values) | Type and Properties | +|-----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------| +| <b>CTIFunction IOC</b> | | At least 1 instance per O-DU<br>GNBDUFunction | +| ctiActivateOnOdu | Activation of CTI functionality on this O-DU<br><br>Unit: none<br>Allowed values: N/A<br>Reserved values : N/A | Type: Boolean<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| <b>CTIconfig DT</b> | | Only 1 instance per CTI Client | +| ctiReportRateCategory | Capability of O-DU to send CTI messages (Category of CTI_MIN).<br><br>Unit: none<br><br>Allowed values: 1..5<br><br>Reserved values : N/A | Type: Integer (UInt8)<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiMessageTimingPerformance | Capability of O-DU to quickly send CTI messages.<br><br>Unit: 20 µs<br><br>Allowed values: 1..255<br><br>Reserved values : N/A | Type: Integer (uint8)<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| supportedCtiVersions | Supported CTI versions on this O-DU. Starts with value 1. | Type: Integer (uint8)<br>Multiplicity: 1..15<br>isOrdered: True<br>isUnique: True | + +| | | | +|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------| +| | Unit: none<br><br>Allowed Values: 1 .. 15<br><br>Reserved values : 0, 16..255 | defaultValue: N/A<br>isNullable: False | +| minNotificationAdvanceTime | PON ranging min notification advance time. If PON ranging is used by one or many TNs, this parameter indicates how soon all CTI clients of this O-DU need that information.<br><br>Unit: ms<br>Allowed Values: 1 .. 65 535<br>Reserved values : N/A | Type : Integer (Uint16)<br>Multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| protocolSubtype | 2-Byte field when L2 encapsulation of CTI messages<br><br><br>Unit: none<br>Allowed values: 0x1<br>Reserved Values: (not defined by WG4 yet) | Type : Integer (Uint8)<br>Multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: 0x1<br>isNullable: False | +| ctiListeningUdpPort | Chosen unique value for all nodes in the network.<br>If a well-known port gets assigned by IANA to CTI, that value shall be used.<br>If there is no UDP/IP communication for CTI on this O-DU, this value does not need to be configured.<br><br>Unit: none<br>Allowed values : any unassigned port<br>Reserved Values: already assigned port values by IANA. | Type : Integer (Uint16)<br>Multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiKa | This value (Keep Alive timer) is the maximum time interval between consecutive CTI-Keep-Alive messages between the CTI client and the CTI server.<br><br>Unit : 0,1 s<br>Allowed values : 1..255 (recommended : 30)<br>Reserved Values :N/A | Type : Integer (Uint8)<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiTo | This value (Time Out timer) is the timeout value that a CTI-Beacon-Ack message needs to be received by the CTI client (O-DU) or the CTI server (transport system) before that respective system suspends CTI operations and returns to its CTI configuration state.<br>Shall be > N x CTI Keep-alive value, with N≥2<br><br>Unit : 0,1 s<br>Allowed values : 1..255 (recommended: 100)<br>Reserved Values : N/A | Type : Integer (Uint8)<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| <b>CTIClient IOC</b> | | Multiple instances possible per O-DU | +| ctiClientInfo | Information about this server (free format)<br><br><br>Unit: none | Type: String<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | + +| | | | +|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Allowed Values: N/A<br>Reserved Values: N/A | | +| ctiClientMacAddr | MAC address of CTI client<br><br>Unit : none<br>Allowed values : see RFC 6991 [16]<br>Reserved Values : N/A | Type : string with pattern constraints as per RFC 6991 [16]<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| <b>CTIClientServerStatus</b> | | Multiple instances possible per CTIClient | +| ctiServerRef | CTI server ID being referred to<br><br>Unit: N/A<br>Allowed Values: existing CTI Server ID<br>Reserved Values: N/A | Type: string<br>Multiplicity: 0..*<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiClientServerActivate | Activate CTI connectivity between client/server pair<br><br>Unit : none<br>Allowed values : true, false<br>Reserved Values :N/A | Type : Boolean<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiClientServerConnStatus | Reflects CTI connectivity status of keep-alives between client/server pair<br><br>Unit : none<br>Allowed values : true, false<br>Reserved Values :N/A | Type : Boolean<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| <b>CTISessionGroup DT</b> | | Multiple instances possible per CTI client | +| ctiServerRef | CTI server ID being referred to<br><br>Unit: N/A<br>Allowed Values: existing CTI Server ID<br>Reserved Values: N/A | Type: string<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiConnProfileRef | CTI connectivity profile ID being referred to<br><br>Unit: N/A<br>Allowed Values: existing CTI connectivity profile ID<br>Reserved Values: N/A | Type: string<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| <b>CTISession DT</b> | | Multiple instances possible per CTI Session Group | +| ctiSessionId | Unique reference to TU or TU interface<br><br>Unit : none<br>Allowed values: N/A<br>Reserved Values: N/A | Type: string following MAC address format<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| oRuId | Unique reference to O-RU linked to CTI session ID<br><br>Unit : none<br>Allowed values: N/A<br><br>Reserved values: N/A | Type: string following format: mfg-name_model-name_serial-num<br><br>Multiplicity: 0..1<br>isOrdered: N/A<br><br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| oRuInterfaceId | Unique reference to O-RU interface linked to CTI session ID | Type: string following format: mfg-name_model-name_serial-num_macaddr | + +| | | | +|---------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------| +| | Unit : none<br>Allowed values: N/A<br><br>Reserved values: N/A | Multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiNominalReportMsgInterval | This value is the minimum average interval that is set for a CTI-Report message to be sent from the CTI client to the CTI server. CTI_NOM is selected per CTI Session ID based on mobile slot length, TN CTI rate category, O-DU rate category.<br>CTI-Report messages may be sent less often. Because of queuing in the system, this value should be interpreted as a rate and not as a spacing between packets. Typical values may be 1–2 ms for LTE, or lower for 5G.<br><br>Unit: 0,25 ms<br><br>Allowed Values: 1..20<br>Reserved Values: 21..255 | Type: Integer (Uint8)<br><br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiReportMessagingUseOfType1Ext | Indicates whether to add extension Type 1 for CTI reports of this CTI session<br><br>Unit: none<br>Allowed Values: True, False<br>Reserved Values: N/A | Type: Boolean<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| <b>CTIServer DT</b> | | Multiple instances possible per O-DU | +| ctiServerId | Id of the given server<br><br>Unit: none<br>Allowed Values: N/A<br>Reserved Values: N/A | Type: string<br>Multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiServerInfo | Information about this server (e.g. operator, type, .... Free format)<br><br>Unit: none<br><br>Allowed Values: N/A<br>Reserved Values: N/A | Type: String<br>Multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| connectivityType | Indicates type of connectivity between any CTI client and this CTI server (Ethernet or UDP/IP/Ethernet)<br><br>Unit : none<br>Allowed values : Ethernet, UDPIP<br>Reserved Values : N/A | Type : ENUM<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiServerMacAddr | (if connectivityType = Ethernet) MAC address of CTI server (to be used in CTI messages in L2 connectivity)<br><br>Unit: none<br>Allowed Values: all valid MAC addr | Type: String with pattern constraints<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | + +| | | | +|---------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Reserved Values: N/A | | +| ctiServerHost | <p>(if connectivityType = UDPIP) CTI server described as IP host (IPv4, IPv6 or FQDN to be used for DNS)</p> <p>Unit: none</p> <p>Allowed Values: all valid hosts</p> <p>Reserved values: N/A</p> | <p>Type: string with pattern constraints</p> <p>multiplicity: 0..1</p> <p>isOrdered: N/A</p> <p>isUnique: N/A</p> <p>defaultValue: N/A</p> <p>isNullable: False</p> | +| ctiEnable | <p>Indicates whether CTI communication is to be enabled to this CTI server</p> <p>Unit: none</p> <p>Allowed Values: True, false</p> <p>Reserved Values: N/A</p> | <p>Type: Boolean</p> <p>multiplicity: 1</p> <p>isOrdered: N/A</p> <p>isUnique: N/A</p> <p>defaultValue: N/A</p> <p>isNullable: False</p> | +| supportedCtiVersions | <p>Supported CTI versions on this CTI Server</p> <p>Unit: none</p> <p>Allowed Values: 1..15</p> <p>Reserved Values: 0, 16..255</p> | <p>Type: Integer (UInt8)</p> <p>Multiplicity: 1..15</p> <p>isOrdered: True</p> <p>isUnique: True</p> <p>defaultValue: N/A</p> <p>isNullable: False</p> | +| ctiReportMessagingUseOfType2 | <p>Indicates whether to add extension Type 1 for CTI messages with this CTI server</p> <p>Unit: none</p> <p>Allowed Values: True, False</p> <p>Reserved Values: N/A</p> | <p>Type: Boolean</p> <p>multiplicity: 1</p> <p>isOrdered: N/A</p> <p>isUnique: N/A</p> <p>defaultValue: N/A</p> <p>isNullable: False</p> | +| ponServerInfoUseNotificationsFromThisServer | <p>Indicates whether O-DU does interpret PON notifications from this CTI server. If not, such received messages may be dropped.</p> <p>Only needs to be configured for CTI servers inside PON-based TNs</p> <p>Unit: none</p> <p>Allowed Values: True, False</p> <p>Reserved Values: N/A</p> | <p>Type: Boolean</p> <p>multiplicity: 0..1</p> <p>isOrdered: N/A</p> <p>isUnique: N/A</p> <p>defaultValue: N/A</p> <p>isNullable: False</p> | +| docsisServerInfo | <p>Only needs to be configured for CTI servers inside DOCSIS-based TNs</p> | <p>Type: String</p> <p>multiplicity: 0..1</p> <p>isOrdered: N/A</p> <p>isUnique: N/A</p> <p>defaultValue: N/A</p> <p>isNullable: False</p> | +| <b>CTIFlow DT</b> | | Multiple instances possible per CTI session | +| ctiFlowId | <p>CTI Flow IDs correspond to a set of matching frame and packet classifiers, the matching transport ID (DOCSIS Service Flow ID or PON T-CONT) when taken together with CTI session ID, as well as the mobile flow identifier.</p> <p>Unit: none</p> <p>Allowed Values: 0 .. 0xEF</p> | <p>Type: Integer (UInt8)</p> <p>multiplicity: 1</p> <p>isOrdered: N/A</p> <p>isUnique: N/A</p> <p>defaultValue: N/A</p> <p>isNullable: False</p> | + +| | | | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Reserved Values: 0xF0..0xFF | | +| filterType | Indicates type of filter between a given CTI client and a given CTI server (Ethernet or UDP/IP/Ethernet)<br><br>Unit : none<br>Allowed Values : Ethernet, UDPIP<br>Reserved Values: N/A | Type : ENUM<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| layer2Filter | (if filterType=Ethernet)<br><br>Unit: N/A<br>Allowed Values: N/A<br>Reserved Values: N/A | Type: Layer2Filter (DT)<br>Multiplicity: 0..1 | +| layer3and4Filter | (if filterType=UDPIP)<br><br>Unit: N/A<br>Allowed Values: N/A<br>Reserved Values: N/A | Type: Layer3and4Filter (DT)<br>Multiplicity: 0..1 | +| source-mac | Layer 2 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br><br>Allowed Values: all valid MAC addr<br>Reserved Values: N/A | Type: String with pattern constraints<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| destination-mac | Layer 2 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br><br>Allowed Values: all valid MAC addr<br>Reserved Values: N/A | Type: String with pattern constraints<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: True (per CTI flow)<br>defaultValue: N/A<br>isNullable: False | +| ethertype | Layer 2 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br>Allowed Values: all valid ethertypes<br>Reserved Values: N/A | Type: Integer (Uint16)<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| pcp | Layer 2 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br>Allowed Values: range 0..7<br>Reserved Values: all others | Type: Integer (Uint8)<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: True<br>defaultValue: N/A<br>isNullable: False | +| vlan-id | Layer 2 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none | Type: Integer (Uint16)<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | + +| | | | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Allowed Values: 1..4094<br>Reserved Values: 4095 | | +| source-address | Layer 3 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br>Allowed Values: valid IP addr<br>Reserved Values: N/A | Type: union string (IPv4) & string (IPv6) with pattern constraints<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| source-prefix | Layer 3 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br>Allowed Values: valid IP addr<br>Reserved Values: N/A | Type: union string (IPv4) & string (IPv6) with pattern constraints<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| destination-address | Layer 3 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br>Allowed Values: valid IP addr<br>Reserved Values: N/A | Type: union string (IPv4) & string (IPv6) with pattern constraints<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| destination-prefix | Layer 3 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br>Allowed Values: valid IP addr<br>Reserved Values: N/A | Type: union string (IPv4) & string (IPv6) with pattern constraints<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| dscp | Layer 3 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br>Allowed Values: range 0..63<br>Reserved Values: N/A | Type: Integer (UInt8)<br>Multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| source-port-start | Layer 4 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br>Allowed Values: 0..65535<br>Reserved Values: N/A | Type: Integer (UInt16)<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| source-port-end | Layer 4 filter parameter, from the perspective of upstream packets to TU ingress.<br><br>Unit: none<br>Allowed Values: 0..65535<br>Reserved Values: N/A | Type: Integer (UInt16)<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| destination-port-start | Layer 4 filter parameter, from the perspective of upstream packets to TU | Type: Integer (UInt16)<br>multiplicity: 0..1<br>isOrdered: N/A | + +| | | | +|-------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------| +| | <p>ingress.</p> <p>Unit: none<br/>Allowed Values: 0..65535<br/>Reserved Values: N/A</p> | <p>isUnique: N/A<br/>defaultValue: N/A<br/>isNullable: False</p> | +| destination-port-end | <p>Layer 4 filter parameter, from the perspective of upstream packets to TU ingress.</p> <p>Unit: none<br/>Allowed Values: 0..65535<br/>Reserved Values: N/A</p> | <p>Type: Integer (Uint16)<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: N/A<br/>isNullable: False</p> | +| ipv4-protocol | <p>Layer 3 filter parameter, from the perspective of upstream packets to TU ingress.</p> <p>Unit: none<br/>Allowed Values:<br/>Reserved Values: N/A</p> | <p>Type: Integer (Uint8)<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: N/A<br/>isNullable: False</p> | +| ipv6-traffic-class | <p>Layer 3 filter parameter, from the perspective of upstream packets to TU ingress.</p> <p>Unit: none<br/>Allowed Values:<br/>Reserved Values: N/A</p> | <p>Type: Integer (Uint8)<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: N/A<br/>isNullable: False</p> | +| ipv6-flow | <p>Layer 3 filter parameter, from the perspective of upstream packets to TU ingress.</p> <p>Unit: none<br/>Allowed Values: range 0..1 048 575<br/>Reserved Values: N/A</p> | <p>Type: Integer (Uint32)<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: N/A<br/>isNullable: False</p> | +| ipv6-next-header | <p>Layer 3 filter parameter, from the perspective of upstream packets to TU ingress.</p> <p>Unit: none<br/>Allowed Values:<br/>Reserved Values: N/A</p> | <p>Type: Integer (Uint8)<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: N/A<br/>isNullable: False</p> | +| <b>CTIFlowsInUse DT</b> | | Multiple instances possible per CTI session | +| ctiFlowRef | <p>CTI flow ID being referred to</p> <p>Unit: none<br/>Allowed Values: existing CTI Flow ID<br/>Reserved Values: N/A</p> | <p>Type: Integer (Uint8)<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: N/A<br/>isNullable: False</p> | +| timeIntervalPerReport | <p>Rate of reporting for given Flow ID in given CTI session ID. Max = CTI_NOM of given CTI session ID</p> | <p>Type: Integer (Uint8)<br/>multiplicity: 1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: N/A<br/>isNullable: False</p> | + +| | | | +|------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------| +| | Unit: 0,25 ms<br>Allowed Values: CTI_NOM or integer portion (e.g. 1/2, 1/4, ...) of CTI_NOM<br>Reserved Values: N/A | | +| maxT34Latency | The maximum latency provides a guideline on the latency bound expected for the CTI flow. The latency bound is defined as one-way and is referenced in O-DU between the O-RU and the O-DU (= T34max)<br><br>Unit: 5 µs<br>Allowed Values: 1..65 535<br>Reserved Values: N/A | Type: Integer (Uint16)<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| minLoad | Minimum value (equivalent #Bytes per reported time interval) to be used in the "Bytes requested" field for the CTI flow in use.<br><br>Unit: Mbit/s<br>Allowed Values: 0..255<br>Reserved Values: N/A | Type: Integer (Uint8)<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: 0<br>isNullable: False | +| extraLoadCplane | Extra value (equivalent #Bytes per reported time interval) to be added to the load field for the CTI flow in use.<br><br>Unit: Mbit/s<br>Allowed Values: 0..255<br>Reserved Values: N/A | Type: Integer (Uint8)<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: 0<br>isNullable: False | +| <b>CTIConnProfile DT</b> | | Multiple instances possible per O-DU | +| ctiConnProfileId | Id of a given Connectivity Profile<br><br>Unit: N/A<br>Allowed Values: N/A<br>Reserved Values: N/A | Type: String<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| connectivityType:<br>identical to same<br>attribute in CTIServer<br>DT | | | +| vlanTagForL2 | (if connectivityType = Ethernet)<br><br>(priority-tagged is not recommended)<br><br>Unit: None<br>Allowed Values: 1..4094<br>Reserved Values: 4095 | Type: ietf<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| vlanTagForL3and4 | (if connectivityType = UDPIP)<br><br>Unit: none<br>Allowed Values: 0..4094<br>Reserved Values: N/A | Type: ietf<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| ctiClientHost | (if connectivityType = UDPIP) | Type: inet:host<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A | + +| | | | +|------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------| +| | Unit: none<br>Allowed Values: valid IP addresses<br>Reserved Values: N/A | defaultValue: N/A<br>isNullable: False | +| <b>CTIPattern DT</b> | | Multiple instances possible per O-DU | +| patternId | Uniquely identifies a CTI pattern. The intended use is to describe the bytes per symbol for each symbol or group of symbols within a mobile slot.<br><br>Unit: none<br>Allowed Values: 0x000001 .. 0x00FFFFFF<br>Reserved Values: 0 (means no pattern info) | Type: Integer (UInt32)<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| patternDuration | The length of a single mobile slot time, in units of 125 µs<br><br>Unit: 125 µs<br><br>Allowed Values: 1..255<br>Reserved Values: N/A | Type: Integer (UInt8)<br><br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| patternEvents | This is the number of events per pattern. An event is typically a symbol or a group of symbols within a slot. For example, if a slot contained 14 symbols, there could be 14 events with each being one symbol or 7 events with each being 2 symbols.<br><br>Events are defined to be equally spaced within a duration time with the bytes being delivered at the end of the event.<br><br>Unit: none<br>Allowed Values: 1..255<br>Reserved Values: N/A | Type: Integer (UInt8)<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| patternEventMultiplier | Number of sequential events that have the same byte count. The multiplier variable and the byte count variable are used in pair to describe an event.<br><br>Unit: none<br>Allowed Values: 1..255<br>Reserved Values: N/A | Type: Integer (UInt8)<br>multiplicity: 1..14<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| patternEventBytes | Number of bytes per event. A byte count is allowed to be 0 bytes. A special value of 0xFFFF indicates a residual average, where:<br><br>Residual average =<br>[ CTI byte count - sum(explicit bytes described) ] / sum(events without explicit bytes described)<br><br>Unit: none<br>Allowed Values: 0 .. 0xFFFF<br>Reserved Values: N/A | Type: Integer (UInt16)<br>multiplicity: 1..14<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: N/A<br>isNullable: False | +| patternNormalization | Indicates whether CTI Pattern Event | Type: Boolean | + +| | | | +|--|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------| +| | <p>Bytes are normalized or not normalized to a fixed value for the sum of all Event Bytes per report</p> <p>Unit: none<br/>Allowed Values: True, False<br/>Reserved Values: N/A</p> | <p>multiplicity: 1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: N/A<br/>isNullable: False</p> | +|--|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------| + +# 8 CTI YANG Data Model + +This document specifies the CTI YANG Data Model to be used in the O-DU + +This document also proposes a CTI YANG Data Model to be used in a TN from a generic perspective, with a specific declination for PON OLT and DOCSIS CMTS. The TN YANG Data Model is provided here as information for further distribution towards the corresponding external bodies for their consideration (Broadband Forum for PON, Cable Labs for DOCSIS). + +The YANG Data Model follows a modular approach. + +Structures that are used in the O-DU and that are also proposed for consideration at the TN are defined in module `o-ran-cti-common`. + +The specific structures for the O-DU are defined in module `o-ran-o1-ctiOdu`. Together, the modules `o-ran-cti-common` and `o-ran-o1-ctiOdu` specify CTI for the O-DU side and fit into the wider O-DU YANG model. + +The specific structures for the TN are defined in module `o-ran-cti-tn-generic`, which contains no TN technology specific structures. Technology-specific structures are defined in the separate modules `o-ran-cti-pon` and `o-ran-cti-tn-docsis` respectively. A TN then has to combine `o-ran-cti-common`, `o-ran-cti-tn-generic` and one `tn-technology` module for a full description of CTI YANG, which in turn has to fit into the wider TN YANG model. + +![Figure 8.1: CTI YANG modules and relationships. The diagram illustrates the modular architecture of CTI YANG. At the top, Transport Management and Mobile Management (SMO) are connected via coordination and configuration. Below them, the TN (Transport Network) and O-DU (Open Data Unit) are shown. The TN contains TN Yang and CTI TN Yang modules. The O-DU contains O-DU Yang and CTI O-DU Yang modules. They are connected via CTI control messages (TC plane) and O1 configuration. The bottom section shows the relationship between various modules: o-ran-cti-tn-pon, o-ran-cti-tn-generic, o-ran-cti-tn-docsis, o-ran-cti-common, and o-ran-o1-ctiOdu. These are grouped into 'Proposed YANG templates' and 'O-RAN normative' sections. Arrows indicate 'augments in' and 'imported in' relationships.](ffd1ce05af53f7228fdc36bb1e8cf17b_img.jpg) + +``` + +graph TD + TM[Transport Management] <-->|coordination| MM[Mobile Management SMO] + MM <-->|configuration| ODU[O-DU] + ODU <-->|O1 configuration| MM + + subgraph TN [TN] + TNYang[TN Yang] + CTITNYang[CTI TN Yang] + end + + subgraph ODU_YANG [O-DU] + ODUYang[O-DU Yang] + CTIODUYang[CTI O-DU Yang] + end + + TNYang <-->|CTI control messages TC plane| CTIODUYang + CTITNYang <-->|CTI control messages TC plane| CTIODUYang + + subgraph Proposed_YANG_templates [Proposed YANG templates] + o_ran_cti_tn_pon[o-ran-cti-tn-pon] + o_ran_cti_tn_generic[o-ran-cti-tn-generic] + o_ran_cti_tn_docsis[o-ran-cti-tn-docsis] + o_ran_cti_common[o-ran-cti-common] + end + + subgraph O_RAN_normative [O-RAN normative] + o_ran_o1_ctiOdu[o-ran-o1-ctiOdu] + end + + o_ran_cti_tn_pon -->|augments in| o_ran_cti_tn_generic + o_ran_cti_tn_docsis -->|augments in| o_ran_cti_tn_generic + o_ran_cti_tn_generic -->|imported in| o_ran_cti_common + o_ran_cti_common -->|imported in| o_ran_o1_ctiOdu + o_ran_o1_ctiOdu -->|imported in| o_ran_cti_common + +``` + +Figure 8.1: CTI YANG modules and relationships. The diagram illustrates the modular architecture of CTI YANG. At the top, Transport Management and Mobile Management (SMO) are connected via coordination and configuration. Below them, the TN (Transport Network) and O-DU (Open Data Unit) are shown. The TN contains TN Yang and CTI TN Yang modules. The O-DU contains O-DU Yang and CTI O-DU Yang modules. They are connected via CTI control messages (TC plane) and O1 configuration. The bottom section shows the relationship between various modules: o-ran-cti-tn-pon, o-ran-cti-tn-generic, o-ran-cti-tn-docsis, o-ran-cti-common, and o-ran-o1-ctiOdu. These are grouped into 'Proposed YANG templates' and 'O-RAN normative' sections. Arrows indicate 'augments in' and 'imported in' relationships. + +Figure 8.1 : CTI YANG modules and relationships + +## 8.1 CTI YANG Data Model Related to O-DU + +### 8.1.1 Overview + +The `o-ran-o1-ctiOdu` module imports the `o-ran-cti-common` module and uses its structures. + +The `o-ran-o1-ctiOdu` module only describes the CTI aspect of the O-DU as stand-alone module (together with `o-ran-cti-common`). It shall be imported in the wider O-DU YANG structure for those O-DUs that support CTI. For O-DUs that do not support CTI there is no change in their YANG structure. + +### 8.1.2 o-ran-cti-common + +The `o-ran-cti-common` module defines common structures for the other modules, rather than commonly configured values. The actual configured values have to be coordinated between the different modules (by the RAN SMO and transport OSS) for consistency. + +As an example, a given CTI flow ID may be re-used in multiple CTI sessions between a CTI server and a CTI client, but then represents the same Ethernet / UDPIP filters. Obviously its filter definition shall be consistent between both TN and O-DU sides. + +![](cf6bd9ff33df5fe5a08f2cf4cf1886c6_img.jpg) + +**o-ran-cti-common (or-ctic)** + +| | | | +|--------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| localIpv4OrIpv6 "typedef" | ctiVersion "typedef" | EtherType "typedef" | +| ctiTimersGrp "grouping"<br>* ctiKa (Keep Alive)<br>* ctiTo (Time Out) | subtypeGrp "grouping"<br>* protocolSubtype | ctiUdpListeningPortGrp "grouping"<br>* ctiUdpListeningPort | +| ctiPatternGrp "grouping"<br>* patternId<br>* patternDuration<br>* patternEvents<br>* patternEventMultiplier<br>* patternEventBytes<br>* patternNormalization | layer2FilterGrp "grouping"<br>* source-mac<br>* destination-mac<br>* etherType<br>* pcp<br>* vlan-id | layer3and4FilterGrp "grouping"<br>* source-address<br>* source-prefix<br>* destination-address<br>* destination-prefix<br>* dscp<br>* source-port-start<br>* source-port-end<br>* destination-port-start<br>* source-port-end<br>* ipv4-protocol<br>* ipv6-traffic-class<br>* ip6-flow-label<br>* ipv6-next-header | + +**Figure 8.2 : Schematic overview of parameters in module o-ran-cti-common** + +### 8.1.3 o-ran-o1-ctiOdu + +The CTIClient IOC is augmented in the GNBDUFunction IOC of the O-DU. The CTIConfig IOC follows the IM of **Figure 7.6**, but its integration with augmentation in the YANG file is for further study. `o-ran-o1-ctiOdu` uses several typedefs and groupings from `o-ran-cti-common`. + +![Schematic overview of parameters in module o-ran-o1-ctiOdu. The diagram shows a hierarchical structure of YANG model groups. The outermost container is 'IOC ManagedElement', which contains 'IOC GNBDFunction'. Inside 'IOC GNBDFunction' is 'IOC CTIFunction'. 'IOC CTIFunction' contains several groups: 'CTIFunctionGrp' (with parameter '* ctiActivateOnOdu'), 'CTIClientGrp' (with parameters '* ctiClientMacAddr' and '* ctiClientInfo'), 'CTIPatternGrp' (with parameter '* uses or-ctic:ctiPatternGrp'), 'CTIServerGrp' (with parameters '* ctiServerId', '* ctiServerInfo', '* connectivityType', '* (when connectivity type = Ethernet) ctiServerMacAddr', '* (when connectivity type = UDPIP) ctiServerHost', '* ctiEnable', '* supportedCtiVersions', '* ctiReportMessagingUseOfType2', '* ponServerInfoUseNotificationsFromThisServer', and '* docsisServerInfo'), 'CTISessionGroupGrp' (with parameters '* ctiServerRef' and '* ctiConnProfileRef'), and 'CTIFlowGrp' (with parameters '* ctiFlowId', '* filterType', '* (when filter type = Ethernet) layer2Filter (uses or-ctic:layer2FilterGrp)', and '* (when filter type = UDPIP) layer3and4Filter (uses or-ctic:layer3and4FilterGrp)'). 'CTIClientGrp' contains 'CTIClientStatusGrp' (with parameters '* ctiClientServerActivate', '* ctiClientServerConnStatus', and '* ctiServerRef') and 'CTIConfigGrp' (with parameters '* ctiReportRateCategory', '* ctiMessageTimingPerformance', '* supportedCtiVersions', '* minNotificationAdvanceTime (if TN is PON based)', '* uses or-ctic:ctiTimersGrp', '* uses or-ctic:subtypeGrp', and '* uses or-ctic:ctiListeningUdpPortGrp'). 'CTISessionGroupGrp' contains 'CTISessionGrp' (with parameters '* ctiSessionId', '* oRuld', '* oRulInterfaceId', '* ctiNominalReportMsgInterval', and '* ctiReportMessagingUseOfType1Ext') and 'CTISessionConnProfileGrp' (with parameters '* ctiConnProfileId', '* connectivityType', '* (when connectivity type = Ethernet) vlanTagForL2', '* (when connectivity type = UDPIP) vlanTagForL3and4', and '* (when connectivity type = UDPIP) ctiClientHost'). 'CTISessionGrp' contains 'CTISessionFlowsInUseGrp' (with parameters '* timeIntervalPerReport', '* maxT34Latency', '* minLoad', '* extraLoadCplane', and '* ctiFlowRef'). Parameters in blue text indicate they are used from the module 'o-ran-cti-common'.](fd15e7b2d22fc764649a1d1ba9e48f27_img.jpg) + +**o-ran-o1-ctiOdu** + +Schematic overview of parameters in module o-ran-o1-ctiOdu. The diagram shows a hierarchical structure of YANG model groups. The outermost container is 'IOC ManagedElement', which contains 'IOC GNBDFunction'. Inside 'IOC GNBDFunction' is 'IOC CTIFunction'. 'IOC CTIFunction' contains several groups: 'CTIFunctionGrp' (with parameter '\* ctiActivateOnOdu'), 'CTIClientGrp' (with parameters '\* ctiClientMacAddr' and '\* ctiClientInfo'), 'CTIPatternGrp' (with parameter '\* uses or-ctic:ctiPatternGrp'), 'CTIServerGrp' (with parameters '\* ctiServerId', '\* ctiServerInfo', '\* connectivityType', '\* (when connectivity type = Ethernet) ctiServerMacAddr', '\* (when connectivity type = UDPIP) ctiServerHost', '\* ctiEnable', '\* supportedCtiVersions', '\* ctiReportMessagingUseOfType2', '\* ponServerInfoUseNotificationsFromThisServer', and '\* docsisServerInfo'), 'CTISessionGroupGrp' (with parameters '\* ctiServerRef' and '\* ctiConnProfileRef'), and 'CTIFlowGrp' (with parameters '\* ctiFlowId', '\* filterType', '\* (when filter type = Ethernet) layer2Filter (uses or-ctic:layer2FilterGrp)', and '\* (when filter type = UDPIP) layer3and4Filter (uses or-ctic:layer3and4FilterGrp)'). 'CTIClientGrp' contains 'CTIClientStatusGrp' (with parameters '\* ctiClientServerActivate', '\* ctiClientServerConnStatus', and '\* ctiServerRef') and 'CTIConfigGrp' (with parameters '\* ctiReportRateCategory', '\* ctiMessageTimingPerformance', '\* supportedCtiVersions', '\* minNotificationAdvanceTime (if TN is PON based)', '\* uses or-ctic:ctiTimersGrp', '\* uses or-ctic:subtypeGrp', and '\* uses or-ctic:ctiListeningUdpPortGrp'). 'CTISessionGroupGrp' contains 'CTISessionGrp' (with parameters '\* ctiSessionId', '\* oRuld', '\* oRulInterfaceId', '\* ctiNominalReportMsgInterval', and '\* ctiReportMessagingUseOfType1Ext') and 'CTISessionConnProfileGrp' (with parameters '\* ctiConnProfileId', '\* connectivityType', '\* (when connectivity type = Ethernet) vlanTagForL2', '\* (when connectivity type = UDPIP) vlanTagForL3and4', and '\* (when connectivity type = UDPIP) ctiClientHost'). 'CTISessionGrp' contains 'CTISessionFlowsInUseGrp' (with parameters '\* timeIntervalPerReport', '\* maxT34Latency', '\* minLoad', '\* extraLoadCplane', and '\* ctiFlowRef'). Parameters in blue text indicate they are used from the module 'o-ran-cti-common'. + +**Figure 8.3 : Schematic overview of parameters in module o-ran-o1-ctiOdu** +(including using parameters from module o-ran-cti-common in blue) + +## 8.2 CTI YANG Model Related to TN (informative) + +### 8.2.1 Overview + +The module `o-ran-cti-o-tn-generic` imports the module CTI common. + +The modules `o-ran-cti-o-tn-pon` and `o-ran-cti-o-tn-docsis` import the module CTI common. + +The module `o-ran-cti-o-tn-generic` is augmented with elements of the corresponding technology-specific module (`o-ran-cti-o-tn-pon` or `o-ran-cti-o-tn-docsis`) + +For TNs that do not support CTI there of course is no change in their YANG model. + +### 8.2.2 o-ran-cti-common + +See 5.1.2 + +### 8.2.3 o-ran-cti-tn-generic + +*It includes generic elements, some of which imported from O-RAN-CTI-COMMON* + +**CTI server-client pair;** groups connectivity parameters at L2 or L2 + L3/L4 to communicate CTI messages between a given CTI client and a given CTI server. This element is augmented with either PON-specific or DOCSIS specific parameters. + +**CTI client name;** unique identifier of a given CTI client. The format is free but the values should be aligned between both Transport OSS and Mobile SMO. For example it could be based on concatenation of O-DU Identifier (mfg name\_model name\_serial nb) + “\_” + 2 characters. + +**CTI client;** contains elements per client on an O-DU, amongst which the patterns as defined in that CTI client. The client also contains its unique connectivity parameters: in case of L2 connectivity the client’s MAC address, and in case of UDP/IP connectivity the client’s host (IP address or FQDN). + +**CTI server name;** unique identifier of a given CTI server. The format is free but but the values should be aligned between both Transport OSS and Mobile SMO. For example it could be based on the concatenation of Access Node Identifier (as used in DHCP Agent Circuit ID) + “\_” + 2 characters. The use of Access Node Identifier allows for autodiscovery as described in section 6.3. + +**CTI server;** contains elements per server, amongst which the CTI Session IDs managed by that server. The server element also includes a list of server-client pairs. This allows to define CTI connectivity at per client level for this server. + +**CTI Sessions;** Per CTI session ID the related parameters like CTI client, CTI server, Nominal time interval for the messages, technology-specific session info, and which flows are in use for that CTI session. Each CTI session ID is linked to a single CTI client and single CTI server, and the CTI connectivity parameters can be deduced from the pair server-client. + +**CTI flows in use;** indicates for a given CTI session ID which CTI flows are being used. There is always at least one flow; if there is no classification into different flows this is represented by CTI Flow ID=0x00. Each flow in use also contains the portion of the T34max value that can be spent as latency in the transport system. + +*It also includes technology-specific elements, which are augmented via either o-ran-cti-tn-pon or o-ran-cti-tn-docsis;* + +#### Technology-specific session configuration info: + +For PON refers to the Channel Termination, ONU (or ONU UNI) for a given CTI session ID. This allows to collect all CTI session IDs per Channel Termination (for generating PON ranging notifications) and to link a given CTI session ID to the T-CONT corresponding to that ONU (or ONU UNI). + +For DOCSIS refers to the Cable Modem MAC address + +#### Technology-specific flow configuration info + +For PON this is the T-CONT associated to given CTI session ID + CTI flow ID, to which Cooperative DBA has to allocate bandwidth based on the reports for that CTI flow ID in that CTI session ID, and the associated filter configuration parameters. + +For DOCSIS this is the Service Class Name and L2 flow or UDP/IP flow configuration parameters associated to given CTI session ID + CTI flow ID. + +**Technology-specific client info;** selects whether to enable PON ranging notification, and defines (per CTI client) how much time in advance the messages have to be sent. + +Technology-specific connectivity parameters (e.g. interface on the TN) are added directly into the server-client pair grouping. + +![Schematic overview of parameters in module o-ran-cti-o-tn-generic. The diagram shows a hierarchical structure of parameter groups. At the top is 'o-ran-cti-tn-generic' containing a 'container' cti-tn. Inside this container are several groups: tnCtiCharacteristicsGrp, ctiTimers, ctiTransport, transportType, ctiTnServerGrp, serverClientPair, ctiSessionIdGrp, clientListGrp, ctiFlowsInUseGrp, and patterns. Parameters are color-coded: blue for imported from o-ran-cti-common, yellow for augmented from o-ran-cti-tn-pon, and green for augmented from o-ran-cti-tn-docsis. Relationships are shown with arrows and cardinalities (1, n).](b4cc57a0dafacbb51428df1438c55676_img.jpg) + +Schematic overview of parameters in module o-ran-cti-o-tn-generic. The diagram shows a hierarchical structure of parameter groups. At the top is 'o-ran-cti-tn-generic' containing a 'container' cti-tn. Inside this container are several groups: tnCtiCharacteristicsGrp, ctiTimers, ctiTransport, transportType, ctiTnServerGrp, serverClientPair, ctiSessionIdGrp, clientListGrp, ctiFlowsInUseGrp, and patterns. Parameters are color-coded: blue for imported from o-ran-cti-common, yellow for augmented from o-ran-cti-tn-pon, and green for augmented from o-ran-cti-tn-docsis. Relationships are shown with arrows and cardinalities (1, n). + +**Figure 8.4 : Schematic overview of parameters in module o-ran-cti-o-tn-generic** +(including imported parameters from module o-ran-cti-common (in blue), +including parameters augmented from modules o-ran-cti-tn-pon (in yellow) and o-ran-cti-tn-docsis (in green)) + +Most of the parameters are the equivalent of the same parameters at O-DU side. TN specific parameters are: + +**Table 8.1: TN specific parameters** + +| Name | Data format | Unit | Value range<br>(default value) | Reserved values | Description | +|----------------------|-------------|------|--------------------------------|-----------------|-------------------------------------------------------------------------------------------------------------------| +| maxPortionT34Latency | Uint16 | 5 μs | 0 .. 65535 | N/A | The portion of the maximum T34 latency allocated to TN-TU segment (used to optimize the operation of the TN node) | + +### 8.2.4 o-ran-cti-tn-pon + +![Schematic overview of parameters in module o-ran-cti-tn-pon. The diagram shows a group of parameter groups: ponTransport, ponFlowConfigDataGrp, ponSessionConfigDataGrp, ponCtiEgressIfGrp, and ponRangingInfoGrp. Parameters are color-coded: blue for imported from o-ran-cti-common, yellow for augmented from o-ran-cti-tn-pon, and green for augmented from o-ran-cti-tn-docsis.](710422145a91e48f6e1bb113e89931ff_img.jpg) + +Schematic overview of parameters in module o-ran-cti-tn-pon. The diagram shows a group of parameter groups: ponTransport, ponFlowConfigDataGrp, ponSessionConfigDataGrp, ponCtiEgressIfGrp, and ponRangingInfoGrp. Parameters are color-coded: blue for imported from o-ran-cti-common, yellow for augmented from o-ran-cti-tn-pon, and green for augmented from o-ran-cti-tn-docsis. + +Figure 8.5 : Schematic overview of parameters in module o-ran-cti-tn-pon + +Table 8.2: PON-based TN specific parameters + +| Name | Data format | Unit | Value range<br>(default value) | Reserved values | Description<br>(parameter used in TN, or O-DU, or both) | +|---------------------------------------------------------------------|-------------|------|--------------------------------|-----------------|------------------------------------------------------------------------------------| +| transport technology base | Identity | N/A | "pon-transport" | N/A | Indicates which transport technology-specific module to load in the TN Yang module | +| associatedTcont | (*) | N/A | (*) | N/A | Corresponding T-CONT for the combination CTI Flow ID & CTI session ID | +| oltChannelTerminationRef | (*) | N/A | (*) | N/A | Corresponding OLT Channel Termination (PON port) for a CTI session ID | +| ctiSessionIdIngress;<br>olt-v-ani or olt-v-enet | (*) | N/A | (*) | N/A | Corresponding ONU or ONU UNI for a CTI session ID | +| ctiL2Interface;<br>vlan-subinterface or l2-termination-subinterface | (*) | N/A | (*) | N/A | Reference to a L2 interface on OLT to be used for CTI messaging | +| ctiUseOfIp | boolean | N/A | True / false | N/A | Use of IP transport capabilities on said L2 interface | + +Note: parameters marked with (\*) are from ITU-T PON YANG modules in BBF TR-385 [5] and OLT YANG modules in BBF TR-383 [6]. + +### 8.2.5 o-ran-cti-tn-docsis + +#### o-ran-cti-tn-docsis + +| | | | | +|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------|-------------------------------------------------------------------------------------------------| +| docsis-transport "identity" | docsisFlowConfigDataGrp "grouping"<br>* associatedScn<br>* if Ethernet: L2Flow<br>uses or-cti:layer2FilterGrp<br>* if UDP/IP: udpIpFlow<br>uses or-cti:layer3and4FilterGrp | docsisSessionConfigDataGrp "grouping"<br>* cmMacAddress | docsisCtiConnectivityProfileGrp "grouping"<br>* L4Ctif<br>* ctiServerIpInterfaceRef<br>* vlanId | +|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------|-------------------------------------------------------------------------------------------------| + +Figure 8.6 : Schematic overviews of parameters in module o-ran-cti-tn-docsis + +Table 8.3: DOCSIS-based TN specific parameters + +| Name | Data format | Unit | Value range<br>(default value) | Reserved values | Description<br>(parameter used in TN, or O-DU, or both) | +|---------------------------|-------------------------|------|--------------------------------|-----------------|---------------------------------------------------------------------------------------------------------------------| +| transport technology base | Identity | N/A | "docsis-transport" | N/A | Indicates which transport technology-specific module to load in the TN Yang module | +| associatedScn | String (len 1..15) (**) | N/A | (**) | N/A | Corresponding DOCSIS service class name to tie DOCSIS Service Flow for the combination CTI Flow ID & CTI session ID | +| cmMacAddress | String | N/A | | N/A | Corresponding Cable Modem MAC address for a CTI session ID | + +| | | | | | | +|-------------------------------------------------------------------------------------------|--|--|--|--|-------------------| +| | | | | | (DOCSIS-based TN) | +| Note: parameters marked with (**) are from Cable Labs YANG modules in CL CM-SP-MULPI [10] | | | | | | + +# Annex A O-DU YANG Module Graphical Representation + +The different released version of the set of YANG modules for the O-RU can be downloaded from O-RAN's website <http://www.o-ran.org/specifications/>. The YANG models are available in a zip file, whose name is used to represent the version of the YANG model and follows the numerical format defined in subsection 1.1 with the periods replaced with "-", i.e., YANG models for release 04.00 of the CTI TM specification are available in the file 04-00.zip. This zip file includes all published revisions of the YANG models supporting a particular release of the CTI TM Information Model / Data Model specification. + +The zip file contains two yang files; **o-ran-cti-common** and **o-ran-ol-ctiOdu** + +This Annex provides a set of "tree-views" of the modules to provide a simplified graphical representation of the data models. These trees have been automatically generated using the pyang YANG validator tool. If there are any inconsistencies between the tree representation in this Annex and the yang models, the yang models shall take precedence. + +## A.1 CTIFunction + +The tree structure for the CTIConfig IOC as augmented into GNBDFunction IOC is provided below: + +``` +augment /me3gpp:ManagedElement/gnbdu3gpp:GNBDFunction: + +--rw CTIFunction* [id] {or-features:CTI}? + +--rw id string + +--rw attributes + | +--rw ctiActivateOnOdu boolean + +--rw CTIClient* [id] + | +--rw id string + | +--rw attributes + | | +--rw ctiClientMacAddr? yang:mac-address + | | +--rw ctiClientInfo? string + | | +--rw ctiClientServerStatus* [ctiServerRef] + | | +--rw ctiServerRef + /me3gpp:ManagedElement/gnbdu3gpp:GNBDFunction/CTIFunction/CTIServer/attributes/ctiServerId + | +--rw ctiClientServerActivate boolean + | +--ro ctiClientServerConnStatus boolean + +--rw CTISessionGroup* [id] + | +--rw id string + | +--rw attributes + | | +--rw ctiServerRef + /me3gpp:ManagedElement/gnbdu3gpp:GNBDFunction/CTIFunction/CTIServer/attributes/ctiServerId + | +--rw ctiConnProfileRef + /me3gpp:ManagedElement/gnbdu3gpp:GNBDFunction/CTIFunction/CTISession/attributes/ctiConnProfileId + | +--rw CTISession* [id] + | | +--rw id string + | | +--rw attributes + | | | +--rw ctiSessionId string + | | | +--rw oruId? string + | | | +--rw oruInterfaceId? string + | | | +--rw ctiNominalReportMsgInterval uint8 + | | | +--rw ctiReportMessagingUseOfType1Ext boolean + | | +--rw CTIFlowsInUse* [id] + | | | +--rw id string + | | | +--rw attributes + | | | | +--rw timeIntervalPerReport uint8 + | | | | +--rw maxT34Latency uint16 + | | | | +--rw minLoad? uint8 + | | | | +--rw extraLoadCplane? uint8 + | | | +--rw ctiFlowRef + /me3gpp:ManagedElement/gnbdu3gpp:GNBDFunction/CTIFunction/CTISession/CTIFlow/attributes/ctiFlowId + | +--rw CTIConfig* [id] + | | +--rw id string + | | +--rw attributes +``` + +``` + ++--ro ctiReportRateCategory uint8 ++--ro ctiMessageTimingPerformance uint8 ++--ro supportedCtiVersions* or-ctic:ctiVersion ++--ro minNotificationAdvanceTime? uint16 ++--rw ctiKa uint8 ++--rw ctiTo uint8 ++--rw protocolSubtype? uint16 ++--rw ctiListeningUdpPort inet:port-number ++--rw CTIServer* [id] + +--rw id string + +--rw attributes + | +--rw ctiServerId string + | +--rw ctiServerInfo? string + | +--rw connectivityType enumeration + | +--rw ctiServerMacAddr yang:mac-address + | +--rw ctiServerHost inet:host + | +--rw ctiEnable boolean + | +--rw supportedCtiVersions* or-ctic:ctiVersion + | +--rw ctiReportMessagingUseOfType2 boolean + | +--rw ponServerInfoUseNotificationsFromThisServer? boolean + | +--rw docsisServerInfo? string ++--rw CTIFlow* [id] + +--rw id string + +--rw attributes + | +--rw ctiFlowId uint8 + | +--rw filterType enumeration + | +--rw layer2Filter* [idx] + | | +--rw idx uint32 + | | +--rw sourceMac? yang:mac-address + | | +--rw destinationMac? yang:mac-address + | | +--rw ethertype? ethertype + | | +--rw pcp? or-types:pcp + | | +--rw vlanId? or-types:vlan-id + | +--rw layer3and4Filter* [idx] + | | +--rw idx uint32 + | | +--rw sourceAddress? inet:ip-address + | | +--rw sourcePrefix? inet:ip-prefix + | | +--rw destinationAddress? inet:ip-address + | | +--rw destinationPrefix? inet:ip-prefix + | | +--rw dscp? inet:dscp + | | +--rw sourcePortStart? inet:port-number + | | +--rw sourcePortEnd? inet:port-number + | | +--rw destinationPortStart? inet:port-number + | | +--rw destinationPortEnd? inet:port-number + | | +--rw ipv4Protocol? uint8 + | | +--rw ipv6TrafficClass? uint8 + | | +--rw ipv6Flow? inet:ipv6-flow-label + | | +--rw ipv6NextHeader? uint8 ++--rw CTIConnProfile* [id] + +--rw id string + +--rw attributes + | +--rw ctiConnProfileId string + | +--rw connectivityType enumeration + | +--rw vlanTagForL2? or-types:vlan-id + | +--rw vlanTagForL3and4? or-types:vlan-id + | +--rw ctiClientHost? inet:host ++--rw CTIPattern* [id] + +--rw id string + +--rw attributes + +--rw patternId uint32 + +--rw patternDuration uint8 + +--rw patternEvents uint8 + +--rw patternEventMultiplier uint8 + +--rw patternEventBytes uint16 + +--rw patternNormalization boolean + +``` + +# Annex B TN YANG Data Models (Informative) + +The YANG Data Models are provided in this Annex for informative purposes as proposals. They can be replaced by specifications made outside of O-RAN when they become available. + +## B.1 o-ran-cti-tn-generic.yang + +This includes augmentations with either o-ran-cti-tn-pon.yang or o-ran-cti-doscis.yang depending on the technology used in the TN. + +### o-ran-cti-tn-generic.yang + +``` + +module o-ran-cti-tn-generic { + yang-version 1.1; + namespace "urn:o-ran:cti-tn-generic:2.0"; + prefix "or-cti-tn"; + + import o-ran-cti-common { + prefix or-ctic; + } + + import ietf-yang-types { + prefix yang; + } + + import ietf-inet-types { + prefix inet; + } + + import o-ran-common-identity-refs { + prefix or-refs; + } + + organization "O-RAN Alliance"; + + contact + "www.o-ran.org"; + + description + "This module defines the configuration of for a generic CTI transport node + that implements the O-RAN WG4 Cooperative transport Interface. It is intended + that transport technology specific augmentations will be used to completely define + the configuration of a fully functional CTI Transport Node." + + Copyright 2022 the O-RAN Alliance. + + THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS 'AS IS' + AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE + IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE + ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE + LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR + CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF + SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS + INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN + CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) + ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE + POSSIBILITY OF SUCH DAMAGE. + + Redistribution and use in source and binary forms, with or without + modification, are permitted provided that the following conditions are met: + + * Redistributions of source code must retain the above copyright notice, + this list of conditions and the above disclaimer. + * Redistributions in binary form must reproduce the above copyright notice, + this list of conditions and the above disclaimer in the documentation + +``` + +``` + +1 and/or other materials provided with the distribution. +2 * Neither the Members of the O-RAN Alliance nor the names of its +3 contributors may be used to endorse or promote products derived from +4 this software without specific prior written permission."; +5 +6 revision "2022-04-15" { +7 description +8 "version 3.0.0 +9 +10 1) non-backward compatible changes to switch to camelCase"; +11 +12 reference "ORAN-WG4.CTI-TMP.0-v03.00"; +13 } +14 revision "2020-10-26" { +15 description +16 "version 1.0.0 +17 +18 1) initial version"; +19 +20 reference "ORAN-WG4.CTI-TMP.0-v01.00"; +21 } +22 +23 grouping tnCtiCharacteristics { +24 description "a grouping for tn characteristics"; +25 +26 leaf tnCtiMessageTimingPerformance { +27 type uint8; +28 units 20-microseconds; +29 config false; +30 mandatory true; +31 description +32 "The minimal spacing needed between the arrival time of the CTI message +33 and the start boundary at Ra of the mobile slot N being reported in the message"; +34 } +35 leaf ctiReportRateCategory { +36 type uint8 { +37 range "1..5"; +38 } +39 config false; +40 mandatory true; +41 description "the supported message interval, where 1 = 5ms, 2 = 2ms, 3 = 1 ms +42 4 = 0.5ms, 5 = 0.25 ms"; +43 reference "O-RAN.WG4.CTI-TCP: Table CTI Message Rate Categories for O-DU or TN"; +44 } +45 leaf-list supportedVersions { +46 type or-ctic:ctiVersion; +47 config false; +48 min-elements 1; +49 description "the list of versions of CTI TC-Plane that are supported by the CTI client"; +50 } +51 } +52 +53 grouping clientListGrp { +54 description "a grouping of a CTI client list"; +55 +56 list ctiClient { +57 key name; +58 description "a list of CTI clients"; +59 +60 leaf name { +61 type string; +62 description "the unique name of a CTI client"; +63 } +64 leaf ctiEnable { +65 type boolean; +66 mandatory true; +67 description "whether the client is enabled for CTI"; +68 } +69 leaf-list version { +70 type or-ctic:ctiVersion; +71 min-elements 1; +72 description "the list of version of CTI TC-Plane that can be used with the client"; +73 } +74 +75 choice connectivityType { + +``` + +``` + +1 description "the connectivity type"; +2 case ethernet { +3 leaf ctiClientMacAddr { +4 type yang:mac-address; +5 description "the destination address used for CTI messages to the server"; +6 } +7 } +8 case udpip { +9 leaf ctiClientHost { +10 type inet:host; +11 description "host (remote IP address or FQDN) for the CTI client"; +12 } +13 } +14 } +15 +16 container technologySpecificClientInfo { +17 description +18 "a container to be augmented by technology specific models that is used to configure +19 technology specific parameters for interaction with this client"; +20 } +21 list patterns { +22 key patternId; +23 min-elements 1; +24 description "a list of patterns"; +25 +26 uses or-ctic:ctiPatternGrp; +27 } +28 } +29 } +30 +31 grouping ctiFlowsInUseGrp { +32 description "the cti flow in use group"; +33 list ctiFlows { +34 key ctiFlowId; +35 description "a list of CTI flows"; +36 +37 leaf ctiFlowId { +38 type uint8; +39 description "a CTI flow-id"; +40 } +41 leaf maxPortionT34Latency { +42 type uint16; +43 units 5-microseconds; +44 description +45 "The portion of the maximum T34 latency allocated to TN-TU segment - used to optimize the operation +46 of the TN node"; +47 } +48 container technologySpecificFlowInfo { +49 description +50 "a container to be augmented by technology specific models that is used to configure +51 the technology specific transport parameters associated with the cti-flow-ID in the context of the +52 given cti-session-id"; +53 } +54 } +55 } +56 +57 grouping ctiSessionIdGrp { +58 description "the cti-session-id group"; +59 list ctiSession { +60 key id; +61 description "a CTI session"; +62 +63 leaf id { +64 type string; +65 description "the identity of a cti session"; +66 } +67 leaf ctiClient { +68 type leafref { +69 path "/ctiTn/ctiClient/name"; +70 } +71 mandatory true; +72 description ""; +73 } +74 } +75 leaf ctiTnServer { + +``` + +``` + +1 type leafref { +2 path "/ctiIn/ctiInServer/name"; +3 } +4 mandatory true; +5 description ""; +6 } +7 +8 leaf ctiNominalReportMsgInterval { +9 type uint8; +10 units 0.25-milliseconds; +11 mandatory true; +12 description "the nominal CTI reporting messsage interval"; +13 } +14 +15 uses ctiFlowsInUseGrp; +16 +17 container technologySpecificSessionInfo { +18 description +19 "a container to augmented by technology specific models"; +20 } +21 } +22 } +23 +24 grouping ctiInServerGrp { +25 description "the cti tn server grouping"; +26 list ctiInServer { +27 key name; +28 description "list of cti tn servers"; +29 +30 leaf name { +31 type string; +32 description "a unique name/identity for a cti-tn-server"; +33 } +34 leaf ctiEnable { +35 type boolean; +36 default false; +37 description "whether the cti server is enabled"; +38 } +39 leaf-list ctiSessionIds { +40 type leafref { +41 path "/ctiIn/ctiSession/id"; +42 } +43 config false; +44 description "read-only list of CTI session IDs handled by this CTI server"; +45 } +46 +47 list serverClientPair { +48 key clientName; +49 description "a list of a CTI clients in contact with this CTI server, to be augmented by technology- +50 specific connectivity parameters"; +51 +52 leaf clientName { +53 type leafref { +54 path "/ctiIn/ctiClient/name"; +55 } +56 description "the name of the CTI client"; +57 } +58 } +59 } +60 } +61 +62 container ctiTn { +63 description +64 "the top level container for CTI TN generic, i.e., transport +65 technology agnostic, configuration and operational data"; +66 +67 leaf transportType { +68 type identityref { +69 base or-refs:o-ran-transport-technology-base; +70 } +71 description "a identity ref used in conditional augmentation"; +72 } +73 container ctiTransport { +74 presence "Enable CTI Transport"; +75 description + +``` + +``` + + "container for transport parameters"; + uses or-ctic:subtypeGrp; + uses or-ctic:ctiListeningUdpPortGrp; +} +container ctiTimers { + presence "Enable CTI Timers"; + description + "container for mandatory CTI Timers"; + uses or-ctic:ctiTimersGrp; +} +uses tnCtiCharacteristics; +uses clientListGrp; +uses ctiTnServerGrp; +uses ctiSessionIdGrp; +} +} + +``` + +## B.2 o-ran-cti-tn-pon.yang + +``` + +o-ran-cti-tn-pon.yang + +module o-ran-cti-tn-pon { + yang-version 1.1; + namespace "urn:o-ran:cti-tn-pon:1.0"; + prefix "or-cti-pon"; + + import o-ran-cti-common { + prefix or-ctic; + } + + import o-ran-cti-tn-generic { + prefix or-ctig; + } + + import o-ran-common-identity-refs { + prefix or-refs; + } + + import ietf-interfaces { + prefix if; + } + + import ietf-yang-types { + prefix yang; + } + + import ietf-inet-types { + prefix inet; + } + + import bbf-xpon-if-type { + prefix bbf-xponift; + } + + import bbf-if-type { + prefix bbfift; + } + + import bbf-xpongmtcont { + prefix bbf-xpongmtcont; + } + + organization "O-RAN Alliance"; + + contact + "www.o-ran.org"; + +``` + +``` + +description + "This module defines the configuration of for the CTI transport node that for + PON defined transport nodes that implement the O-RAN WG4 Cooperative transport Interface. + + Copyright 2020 the O-RAN Alliance. + + THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS 'AS IS' + AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE + IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE + ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE + LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR + CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF + SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS + INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN + CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) + ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE + POSSIBILITY OF SUCH DAMAGE. + + Redistribution and use in source and binary forms, with or without + modification, are permitted provided that the following conditions are met: + + * Redistributions of source code must retain the above copyright notice, + this list of conditions and the above disclaimer. + * Redistributions in binary form must reproduce the above copyright notice, + this list of conditions and the above disclaimer in the documentation + and/or other materials provided with the distribution. + * Neither the Members of the O-RAN Alliance nor the names of its + contributors may be used to endorse or promote products derived from + this software without specific prior written permission."; + + revision "2022-06-28" { + description + "version 3.0.0 + 1) non-backward compatible changes to switch to camelCase"; + + reference "ORAN-WG4.CTI-TCP.0-v03.00"; + } + + identity ponTransport { + base "or-refs:o-ran-transport-technology-base"; + description + "an identity corresponding to PON transport"; + } + + grouping ponSessionConfigDataGrp { + description + "A grouping of PON specific info reflecting the ingress point in the PON system the O-RU (interface) + corresponding to a given CTI session ID: OLT Channel Termination, ONU, ONU UNI"; + + leaf oltChannelTerminationRef { + type if:interface-ref; + must "derived-from-or-self(/if:interfaces" + + "/if:interface[if:name=current()]/if:type," + + "'bbf-xponif:channel-termination')" + { + error-message + "Must reference a channel termination."; + } + description "Reference to a PON OLT Channel Termination"; + } + + leaf ctiSessionIdIngress { + type if:interface-ref; + must "derived-from-or-self(/if:interfaces" + + "/if:interface[if:name=current()]/if:type," + + "'bbf-xponif:olt-v-enet') or + derived-from-or-self(/if:interfaces" + + "/if:interface[if:name=current()]/if:type," + + "'bbf-xponif:olt-v-ani')"; + { + error-message + "Must either reference an OLT vENET interface which is the + local representation in the OLT of an ONU UNI + interface, or reference an OLT vANI interface which is the + local representation in the OLT of an ONU"; + } + } + } + +``` + +``` + +1 } +2 description "Reference to an ONU or ONU UNI."; +3 } +4 } +5 } +6 grouping ponFlowConfigDataGrp { +7 description +8 "A T-CONT being used for carrying upstream traffic pertaining to a CTI Session ID + Flow ID"; +9 +10 leaf associatedTcont { +11 type leafref { +12 path '/bbf-xpongemtcont:xpongemtcont/bbf-xpongemtcont:' +13 + 'tconts/bbf-xpongemtcont:tcont/bbf-xpongemtcont:' +14 + 'name'; +15 } +16 description +17 "Reference to a T-CONT."; +18 } +19 } +20 } +21 +22 grouping ponRangingInfoGrp { +23 description "a grouping for PON ranging info"; +24 +25 leaf ponUseNotifications { +26 type boolean; +27 mandatory true; +28 description "whether PON notifications are used to this CTI client"; +29 } +30 leaf ponMinNotificationTa { +31 when "../ponUseNotifications = 'true'"; +32 type uint16; +33 units milliseconds; +34 description "the minimum notification timing advance"; +35 } +36 } +37 +38 grouping ponFlowInfoGrp { +39 description "a grouping for the PON specific flow information"; +40 choice filterType { +41 description "the filter type for this flow"; +42 case ethernet { +43 container l2Flow { +44 must "(sourceMac)or(destinationMac)or(ethertype)or(pcp)or(vlanId)"; +45 description "field(s) for L2 filter"; +46 uses or-ctic:layer2FilterGrp; +47 } +48 } +49 case udpip { +50 container udpipFlow { +51 must +52 "(sourceAddress)or(sourcePrefix)or(destinationAddress)or(destinationPrefix)or(dscp)or((sourcePortStart)and(so +53 urcePortEnd))"; +54 description "field(s) for UDP/IP filter"; +55 uses or-ctic:layer3and4FilterGrp; +56 } +57 } +58 } +59 } +60 +61 grouping ponCtiEgressIfGrp { +62 description "Configuration of the egress interface on OLT for CTI towards CTI client in O-DU"; +63 +64 leaf ctiL2Interface { +65 type if:interface-ref; +66 must "derived-from-or-self(/if:interfaces" +67 + "/if:interface[if:name=current()/if:type," +68 + "'bbfift:vlan-sub-interface') or " +69 + "derived-from-or-self(/if:interfaces" +70 + "/if:interface[if:name=current()/if:type," +71 + "'bbfift:l2-termination') " { +72 error-message +73 "Must reference a vlan-sub-interface or a +74 l2-termination interface."; +75 } + +``` + +``` + + description "Reference to a L2 interface."; + } + leaf ctiUseOfIp { + type boolean; + description "Use IP transport capabilities (RFC 8344) of the L2 interface (if available) for CTI."; + } +} + +augment "/or-ctig:ctiTn/or-ctig:ctiSession/or-ctig:technologySpecificSessionInfo" { + when "(derived-from-or-self(../../transportType," + "'ponTransport'))"; + description "augmentation for session data"; + uses ponSessionConfigDataGrp; +} + +augment "/or-ctig:ctiTn/or-ctig:ctiSession/or-ctig:ctiFlows/or-ctig:technologySpecificFlowInfo" { + when "(derived-from-or-self(../../../transportType," + "'ponTransport'))"; + description "augmentation for flow configuration data"; + uses ponFlowConfigDataGrp; +} + +augment "/or-ctig:ctiTn/or-ctig:ctiSession/or-ctig:ctiFlows/or-ctig:technologySpecificFlowInfo" { + when "(derived-from-or-self(../../../transportType," + "'ponTransport'))"; + description "augmentation for flow configuration data"; + uses ponFlowInfoGrp; +} + +augment "/or-ctig:ctiTn/or-ctig:ctiTnServer/or-ctig:serverClientPair" { + when "(derived-from-or-self(../../transportType," + "'ponTransport'))"; + description "augmentation for CTI interface"; + uses ponCtiEgressIfGrp; +} + +augment "/or-ctig:ctiTn/or-ctig:ctiClient/or-ctig:technologySpecificClientInfo" { + when "(derived-from-or-self(../../transportType," + "'ponTransport'))"; + description "augmentation for PON ranging info"; + uses ponRangingInfoGrp; +} + +} + +``` + +## B.3 o-ran-cti-tn-docsis.yang + +``` + +o-ran-cti-tn-docsis.yang + +module o-ran-cti-tn-docsis { + yang-version 1.1; + namespace "urn:o-ran:cti-tn-docsis:2.0"; + prefix "or-cti-docsis"; + + import o-ran-cti-common { + prefix or-ctic; + } + + import o-ran-cti-tn-generic { + prefix or-ctig; + } + + import ietf-yang-types { + prefix yang; + } + + import o-ran-common-yang-types { + prefix or-types; + } + + import o-ran-common-identity-refs { + prefix or-refs; + +``` + +``` + +} +organization "O-RAN Alliance"; + +contact + "www.o-ran.org"; + +description + "This module defines the configuration of for the CTI transport + node that for DOCSIS defined transport nodes that implement the + O-RAN WG4 Cooperative transport Interface. + + Copyright 2022 the O-RAN Alliance. + + THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS + 'AS IS' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT + LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS + FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE + COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, + INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL + DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE + GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS + INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, + WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING + NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF + THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. + + Redistribution and use in source and binary forms, with or without + modification, are permitted provided that the following conditions are met: + + * Redistributions of source code must retain the above copyright notice, + this list of conditions and the above disclaimer. + * Redistributions in binary form must reproduce the above copyright notice, + this list of conditions and the above disclaimer in the documentation + and/or other materials provided with the distribution. + * Neither the Members of the O-RAN Alliance nor the names of its + contributors may be used to endorse or promote products derived from + this software without specific prior written permission."; + +revision "2022-04-15" { + description + "version 3.0.0 + + 1) non-backward compatible changes to switch to camelCase"; + + reference "ORAN-WG4.CTI-TMP.0-v03.00"; +} + +identity docsis-transport { + base "or-refs:o-ran-transport-technology-base"; + description + "an identity corresponding to DOCSIS transport"; +} + +grouping docsisSessionConfigDataGrp { + description + "A grouping of DOCSIS specific CTI session info."; + + leaf cmMacAddress { + type yang:mac-address; + description "a MAC address on the DOCSIS equipment connected to O-RU"; + } +} + +grouping docsisFlowConfigDataGrp { + description + "A grouping for DOCSIS specific flow in use info"; + + leaf associatedScn { + type string { length "1..15"; } + description + "This key indicates the Service Class Name associated with + this CTI flow. DOCSIS specifies that the maximum + size is 16 ASCII characters including a terminating zero."; + reference "Information Model Mapping: CM-SP-CCAP-OSSiv4.0 + +``` + +``` + +1 ServiceClass::Name"; +2 } +3 choice filterType { +4 description "the filter type"; +5 case ethernet { +6 container l2Flow { +7 must "(sourceMac)or(destinationMac)or(ethertype)or(pcp)or(vlanId)"; +8 description "the layer 2 flow"; +9 uses or-ctic:layer2FilterGrp; +10 } +11 } +12 case udpip { +13 container udpipFlow { +14 must "(sourceAddress)or(sourcePrefix)or(destinationAddress)or(destinationPrefix)" +15 + +16 "or(dscp)or((sourcePortStart)and(sourcePortEnd))or((destinationPortStart)and(destinationPortEnd))" +17 + "or(ipv4Protocol)or(ipv6TrafficClass)or(ipv6Flow)or(ipv6NextHeader)"; +18 description "the udpip flow container"; +19 uses or-ctic:layer3and4FilterGrp; +20 } +21 } +22 } +23 } +24 +25 grouping docsisCtiConnectivityProfileGrp { +26 description +27 "Configuration data for CTI conectivity."; +28 +29 container l4CtiIf { +30 description +31 "A container for a l4 cti interface"; +32 +33 leaf ctiServerIpInterfaceRef { +34 type or-ctic:localIpv4orIpv6; +35 description "a local IP address on the TN (CMTS) for the CTI Server"; +36 } +37 +38 leaf vlanId { +39 type or-types:vlan-id; +40 description "an optional vlan id associated with this IP/host CTI connection"; +41 } +42 } +43 } +44 +45 augment "/or-ctig:ctiTn/or-ctig:ctiSession/or-ctig:technologySpecificSessionInfo" { +46 when "(derived-from-or-self(..../transportType, " +47 + "'docsis-transport'))"; +48 description "augmentation for session data"; +49 uses docsisSessionConfigDataGrp; +50 } +51 +52 augment "/or-ctig:ctiTn/or-ctig:ctiSession/or-ctig:ctiFlows/or-ctig:technologySpecificFlowInfo" { +53 when "(derived-from-or-self(..../transportType, " +54 + "'docsis-transport'))"; +55 description "augmentation for flow data"; +56 uses docsisFlowConfigDataGrp; +57 } +58 +59 augment "/or-ctig:ctiTn/or-ctig:ctiTnServer/or-ctig:serverClientPair" { +60 when "(derived-from-or-self(..../transportType, 'docsis-transport'))"; +61 description "augmentation for cti profile"; +62 uses docsisCtiConnectivityProfileGrp; +63 } +64 } +65 } +66 + +``` + +# --- Revision History + +| Date | Revision | Description | +|------------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.02.23 | 04.00 | Completion of Information Model and YANG Model, move of the informational TN YANG files into informative Annex of the TMP spec, adaptation of the document to the O-RAN TSC document drafting rules. | +| 2022.07.14 | 03.00 | Updated Information Model and YANG Data Model, alignment on O1 guidelines | +| 2021.03.05 | 02.00 | Updated related parameters to support CTI pattern descriptor | +| 2020.11.05 | 01.00 | First release of the specification | + +# --- History + +| Date | Revision | Description | +|------------|----------|----------------------------------| +| 2023.02.23 | 04.00 | Published as Final version 04.00 | +| 2022.07.14 | 03.00 | Published as Final version 03.00 | +| 2021.03.05 | 02.00 | Published as Final version 02.00 | +| 2020.11.05 | 01.00 | Published as Final version 01.00 | \ No newline at end of file diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/065ffb6f6f72ea1204012cda1dbf5b5c_img.jpg b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/065ffb6f6f72ea1204012cda1dbf5b5c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0b2c9568e61b6c65f83c4ce3702e56bef8d10d62 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/065ffb6f6f72ea1204012cda1dbf5b5c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ec6ee54f17c588e7fd8dbe28a9d931ea746f7d6497506e94eb5b6838ee4d9fe0 +size 4137 diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/2daabaa1a191eb1be4ee824ba5c1205b_img.jpg b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/2daabaa1a191eb1be4ee824ba5c1205b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..410cc87454562a3fb7b6cb494ec3cb2da35b5d2f --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/2daabaa1a191eb1be4ee824ba5c1205b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:08803f6a6ca7c2a6a30966ad24ed336e72dc842768d274acaa11ea2d056fa685 +size 40632 diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/40e7a1737a6eb186da4bfc2c909de095_img.jpg b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/40e7a1737a6eb186da4bfc2c909de095_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..96aca2690998e7c6b70d4ec4a949403b2bbc5810 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/40e7a1737a6eb186da4bfc2c909de095_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b962fb013f79124bc26502a60e7d0a3d3affaf87cb7cbe3b0367a9be630b7bc +size 67069 diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/4b1dc0ee1de25091d491adb41b78cff6_img.jpg b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/4b1dc0ee1de25091d491adb41b78cff6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..17308a58978080498017ac5c4bd1425f5969a809 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/4b1dc0ee1de25091d491adb41b78cff6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:927217b105e7f8ba7b2acf05734c990d9c9f938b92b90994170ac21cab48b3ea +size 71220 diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/5c38e6d0d65b9c37b41b734c20e6dc34_img.jpg b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/5c38e6d0d65b9c37b41b734c20e6dc34_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5c08e28f864ddb34af716d1108b024a75ffa6d7e --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/5c38e6d0d65b9c37b41b734c20e6dc34_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:454418b04340375d022432cde934fc22a597df0834a057327abd498fa600a71d +size 68287 diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/6e43e95601251e761b5354e5ae169daf_img.jpg b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/6e43e95601251e761b5354e5ae169daf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..06052ff498f01dc00538af3a34de656f2d448c4f --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/6e43e95601251e761b5354e5ae169daf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b096cf8af8781041924dfcaaa131f748732808134de68592a83a698b384341e6 +size 4029 diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/a662186f488ad1cde43011203483a607_img.jpg b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/a662186f488ad1cde43011203483a607_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0083bbcd477a440af246531da0d9ca834fcef69d --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/a662186f488ad1cde43011203483a607_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:031897db0b5eb2ce58429303a824c2474348172755ed5338c9b2971a7476ff61 +size 4029 diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/b4f9cbdd0137e28a2c6a5f8c258dc4bb_img.jpg b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/b4f9cbdd0137e28a2c6a5f8c258dc4bb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8796b1b4f8a86fca31f9afa85c02cecb58ceb5e8 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/b4f9cbdd0137e28a2c6a5f8c258dc4bb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ad4dcd3b30323e1b15c085d879279ee712880b8a7fa33624750c805c5064a14 +size 37423 diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/e302684185b47169a4b530bcca918699_img.jpg b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/e302684185b47169a4b530bcca918699_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..04b0438918bd3a3d0f161bbcc883d6c13e58fa5a --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/e302684185b47169a4b530bcca918699_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:47129150e2ecaf8de3b16cbd985703f69bc18bb661b5cd6f0df829a610cd3175 +size 4134 diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/fb5a0e58b6e405c4bc82b2d9d85275d4_img.jpg b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/fb5a0e58b6e405c4bc82b2d9d85275d4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7b635cbce0a176016a26a55fdd8c8263f51ef84 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/fb5a0e58b6e405c4bc82b2d9d85275d4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8af07c76f8bb0eb6f44a99baad844375e1dbae3f28542ecfd149fc7f3485db5a +size 3865 diff --git a/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/raw.md b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..3cb6f15aca6f71ca6614b44ef885da041a83265a --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00/raw.md @@ -0,0 +1,4623 @@ + + +# --- **O-RAN Work Group 5 (Open F1/W1/E1/X2/Xn interface Workgroup)****O1 Interface specification for O-CU-UP and O-CU-CP** + +Copyright © 2024 by O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189. + +# Contents + +| | | | +|----|-----------------------------------------------------------|----| +| 1 | Contents ..... | 2 | +| 2 | List of Figures ..... | 6 | +| 3 | List of Tables..... | 7 | +| 4 | Foreword ..... | 7 | +| 5 | Modal verbs terminology ..... | 7 | +| 6 | 1 Scope..... | 8 | +| 7 | 2 References ..... | 8 | +| 8 | 2.1 Normative references ..... | 8 | +| 9 | 2.2 Informative references..... | 8 | +| 10 | 3 Definitions of terms symbols and abbreviations..... | 9 | +| 11 | 3.1 Terms ..... | 9 | +| 12 | 3.2 Symbols..... | 9 | +| 13 | 3.3 Abbreviations and acronyms ..... | 9 | +| 14 | 3.4 Conventions..... | 9 | +| 15 | 3.5 Revision and compatibility handling..... | 10 | +| 16 | 4 High Level Description ..... | 10 | +| 17 | 4.1 Top level functional description and terminology..... | 10 | +| 18 | 4.1.1 Architecture for O-RAN WG5 functional split ..... | 10 | +| 19 | 4.1.2 O1 interface for O-CU architecture model ..... | 10 | +| 20 | 4.1.3 Transport Network..... | 10 | +| 21 | 4.2 Interfaces ..... | 10 | +| 22 | 5 PNF Startup and Registration Management ..... | 11 | +| 23 | 5.1 PNF Plug-n-Play ..... | 11 | +| 24 | 5.2 PNF Registration..... | 11 | +| 25 | 6 Heartbeat Management Services ..... | 11 | +| 26 | 6.1 Heartbeat Notification ..... | 11 | +| 27 | 6.2 Heartbeat Control..... | 11 | +| 28 | 7 PNF Software Management Services..... | 12 | +| 29 | 7.1 Software Package Naming and Content ..... | 12 | +| 30 | 7.2 Software Inventory..... | 12 | +| 31 | 7.3 Software Download..... | 12 | +| 32 | 7.4 Software Activation Pre-Check ..... | 12 | +| 33 | 7.5 Software Activate..... | 12 | +| 34 | 8 Performance Management ..... | 12 | +| 35 | 8.1 Performance Data File Reporting..... | 12 | +| 36 | 8.2 Performance Data Streaming..... | 12 | +| 37 | 8.3 Measurement Job Control..... | 12 | +| 38 | 9 Fault Management ..... | 13 | +| 39 | 9.1 Fault Notification..... | 13 | +| 40 | 9.2 Fault Supervision Control..... | 13 | +| 41 | 10 File Management ..... | 13 | +| 42 | 10.1 File Structure ..... | 13 | +| 43 | 10.2 Notification notifyFileReady ..... | 14 | +| 44 | 10.3 File Management Operation: listAvailableFiles..... | 15 | +| 45 | 10.4 File Management Operation: transferFile..... | 15 | +| 46 | 10.5 File Management Operation: downloadFile ..... | 15 | + +| | | | | +|----|--------|-------------------------------------------------------------------------------------|----| +| 1 | 11 | Provisioning Management..... | 16 | +| 2 | 11.1 | Configuration for O-CU ..... | 16 | +| 3 | 11.2 | Notification aspect ..... | 17 | +| 4 | 11.2.1 | Subscribing for O-CU notification from SMO ..... | 17 | +| 5 | 11.3 | Information model for O-CU-CP ..... | 17 | +| 6 | 11.3.1 | Imported and associated information entities ..... | 17 | +| 7 | 11.3.2 | Class diagram ..... | 17 | +| 8 | 11.3.3 | Class definition..... | 20 | +| 9 | 11.3.4 | Attribute definitions..... | 22 | +| 10 | 12 | Trace Management Services..... | 24 | +| 11 | 12.1 | Call Trace ..... | 24 | +| 12 | 12.2 | Minimization of Drive Testing (MDT)..... | 24 | +| 13 | 12.3 | Radio Link Failure (RLF)..... | 24 | +| 14 | 12.4 | RRC Connection Establishment Failure (RCEF) ..... | 25 | +| 15 | 12.5 | Trace Control..... | 25 | +| 16 | 12.6 | Streaming Trace ..... | 25 | +| 17 | | Annex A (informative) : Counter definition..... | 26 | +| 18 | A.1 | NR PDCP performance counters (Type A): ..... | 26 | +| 19 | A.1.1 | Distribution of UE per UL received data volume ..... | 26 | +| 20 | A.1.2 | Distribution of DL UE throughput in O-CU..... | 27 | +| 21 | A.1.3 | Total discarded UL PDCP SDU volume ..... | 28 | +| 22 | A.1.4 | UL PDCP SDU volume discarded due to bearer release ..... | 28 | +| 23 | A.1.5 | Total discarded DL PDCP SDU volume discarded..... | 29 | +| 24 | A.1.6 | DL PDCP SDU volume discarded due to bearer release ..... | 29 | +| 25 | A.1.7 | DL PDCP SDU volume discarded due to out of memory ..... | 30 | +| 26 | A.1.8 | PDCP transmission stop ..... | 30 | +| 27 | A.1.9 | UL F1-U packet loss rate ..... | 31 | +| 28 | A.1.10 | UL PDCP SDU Loss Rate ..... | 31 | +| 29 | A.1.11 | DL PDCP SDU Loss Rate ..... | 32 | +| 30 | A.1.12 | DL F1-U packet loss rate ..... | 32 | +| 31 | A.2 | NR PDCP performance counters (Type B): ..... | 33 | +| 32 | A.2.1 | UL PDCP SDU Data Volume ..... | 33 | +| 33 | A.2.2 | UL PDCP SDU Data Volume on X2 Interface ..... | 33 | +| 34 | A.2.3 | UL PDCP SDU Data Volume on Xn Interface ..... | 34 | +| 35 | A.2.4 | DL PDCP SDU Data Volume ..... | 35 | +| 36 | A.2.5 | DL PDCP SDU Data Volume on X2 Interface ..... | 35 | +| 37 | A.2.6 | DL PDCP SDU Data Volume on Xn Interface ..... | 36 | +| 38 | A.2.7 | UL PDCP SDU Data Volume per cell ..... | 37 | +| 39 | A.2.8 | UL PDCP SDU Data Volume on X2 Interface per cell..... | 37 | +| 40 | A.2.9 | UL PDCP SDU Data Volume on Xn Interface per cell..... | 38 | +| 41 | A.2.10 | DL PDCP SDU Data Volume per cell ..... | 38 | +| 42 | A.2.11 | DL PDCP SDU Data Volume on X2 Interface per cell..... | 39 | +| 43 | A.2.12 | DL PDCP SDU Data Volume on Xn Interface per cell..... | 39 | +| 44 | A.3 | NR S1-U Interface Performance Counters ..... | 40 | +| 45 | A.3.1 | UL PDCP SDU volume transmitted via S1-U UL GTP-U tunnel ..... | 40 | +| 46 | A.3.2 | DL PDCP SDU volume received via S1-U DL GTP-U tunnel..... | 40 | +| 47 | A.3.3 | UL PDCP SDUs transmitted via S1-U UL GTP-U tunnel ..... | 41 | +| 48 | A.3.4 | DL PDCP SDUs transmitted via S1-U DL GTP-U tunnel ..... | 41 | +| 49 | A.4 | NR NG-U Interface Performance Counters..... | 42 | +| 50 | A.4.1 | UL PDCP SDU volume transmitted via NG-U UL GTP-U tunnel..... | 42 | +| 51 | A.4.2 | DL PDCP SDU volume received via NG-U DL GTP-U tunnel ..... | 42 | +| 52 | A.5 | NR X2-U Interface performance counters (O-CU)..... | 43 | +| 53 | A.5.1 | UL PDCP SDU volume received via X2-U UL GTP-U tunnel (X2-U UL data forwarding)..... | 43 | +| 54 | A.5.2 | DL PDCP SDU volume received via X2-U DL GTP-U tunnel (X2-U DL data forwarding)..... | 43 | +| 55 | A.6 | NR Xn-U Interface performance counters (O-CU)..... | 44 | +| 56 | A.6.1 | UL PDCP SDU volume received via Xn-U UL GTP-U tunnel (Xn-U UL data forwarding)..... | 44 | +| 57 | A.6.2 | DL PDCP SDU volume received via Xn-U DL GTP-U tunnel (Xn-U DL data forwarding)..... | 44 | +| 58 | A.7 | NR X2-C Interface performance counters (O-CU)..... | 45 | +| 59 | A.7.1 | Transmitted X2-C messages..... | 45 | +| 60 | A.7.2 | Received X2-C messages..... | 45 | + +| | | | +|----|----------------------------------------------------------------------------------------------------------------|----| +| 1 | A.8 NR Xn-C Interface performance counters (O-CU)..... | 46 | +| 2 | A.8.1 Transmitted Xn-C messages..... | 46 | +| 3 | A.8.2 Received Xn-C messages..... | 46 | +| 4 | A.9 NR F1-C Interface performance counters (O-CU-CP)..... | 47 | +| 5 | A.9.1 Transmitted F1-C messages ..... | 47 | +| 6 | A.9.2 Received F1-C messages..... | 47 | +| 7 | A.10 Number of UE Contexts for EN-DC..... | 47 | +| 8 | A.10.1 Max SN terminated split bearer UE Contexts..... | 47 | +| 9 | A.10.2 Max SN terminated MCG bearer UE Contexts..... | 48 | +| 10 | A.10.3 Average SN terminated split bearer UE Contexts..... | 49 | +| 11 | A.10.4 Average SN terminated MCG bearer UE Contexts..... | 49 | +| 12 | A.10.5 Total DL CA UE Contexts PSCell (100ms) ..... | 50 | +| 13 | A.10.6 Total DL CA UE Contexts PSCell (10s)..... | 51 | +| 14 | A.10.7 Total DL CA UE Contexts SCell (100ms) ..... | 52 | +| 15 | A.10.8 Total DL CA UE Contexts SCell (10s) ..... | 52 | +| 16 | A.10.9 Max DL CA UE Contexts PSCell (100ms) ..... | 53 | +| 17 | A.10.10 Max DL CA UE Contexts PSCell (10s) ..... | 54 | +| 18 | A.10.11 Max DL CA UE Contexts SCell (100ms) ..... | 55 | +| 19 | A.10.12 Max DL CA UE Contexts SCell (10s) ..... | 55 | +| 20 | A.11 Number of UE Contexts for SA..... | 56 | +| 21 | A.11.1 Total RRC Connected UE Contexts..... | 56 | +| 22 | A.11.2 Total UE Contexts Per QoS..... | 57 | +| 23 | A.11.3 Total SCell Configuration UE Contexts..... | 58 | +| 24 | A.11.4 Total Measurement Gap UE Contexts..... | 59 | +| 25 | A.11.5 Max RRC Connected UE Contexts..... | 59 | +| 26 | A.11.6 Max UE Contexts Per QoS..... | 60 | +| 27 | A.11.7 Max SCell Configuration UE Contexts..... | 61 | +| 28 | A.11.8 Max Measurement Gap UE Contexts..... | 62 | +| 29 | A.11.9 Total emergency UE Contexts..... | 62 | +| 30 | A.11.10 Total high priority access UE Contexts..... | 63 | +| 31 | A.11.11 Max emergency UE Contexts ..... | 64 | +| 32 | A.11.12 Max high priority access UE Contexts ..... | 65 | +| 33 | A.11.13 Total SN terminated split bearer UE Contexts in NR-DC ..... | 66 | +| 34 | A.11.14 Max SN terminated split bearer UE Contexts in NR-DC ..... | 67 | +| 35 | A.11.15 Total UE Contexts during voice call ..... | 68 | +| 36 | A.12 Monitoring of procedure for EN-DC ..... | 68 | +| 37 | A.12.1 Number of SgNB Addition procedure attempted for each Cell ..... | 68 | +| 38 | A.12.2 Number of SgNB Addition procedure successfully for each Cell..... | 69 | +| 39 | A.12.3 Number of SgNB Addition procedure attempted for each neighbour eNB ..... | 69 | +| 40 | A.12.4 Number of SgNB Addition procedure successfully for each neighbour eNB..... | 70 | +| 41 | A.12.5 Number of SgNB modification procedure attempted for each neighbour eNB ..... | 70 | +| 42 | A.12.6 Number of SgNB modification procedure successfully for each neighbour eNB..... | 71 | +| 43 | A.13 Monitoring of RRC Connection for EN-DC..... | 71 | +| 44 | A.13.1 Number of Measurement Gap Coordination for per FR2 gap via SRB3 attempted ..... | 71 | +| 45 | A.13.2 Number of Measurement Gap Coordination for per FR2 gap via SRB3 successfully ..... | 72 | +| 46 | A.13.3 Number of Inter gNB-DU PSCell Change via SRB3 attempted..... | 72 | +| 47 | A.13.4 Number of Inter gNB-DU PSCell Change via SRB3 successfully ..... | 73 | +| 48 | A.13.5 Number of Intra gNB-DU PSCell Change via SRB3 attempted..... | 73 | +| 49 | A.13.6 Number of Intra gNB-DU PSCell Change via SRB3 successfully ..... | 74 | +| 50 | A.14 Monitoring of RRC Connection for SA ..... | 74 | +| 51 | A.14.1 Number of initial RRC Connection requests ..... | 74 | +| 52 | A.14.2 Number of RRC connection completions for initial RRC Connection requests ..... | 74 | +| 53 | A.14.3 Number of retransmission RRC Connections requests..... | 75 | +| 54 | A.14.4 Number of RRC Connections completions for retransmission RRC Connections requests ..... | 75 | +| 55 | A.14.5 Number of incomplete RRC Connection by failed resource allocations ..... | 76 | +| 56 | A.14.6 Number of incomplete RRC Connection by O-CU internal error..... | 76 | +| 57 | A.14.7 Number of initial RRC Connection requests each Establishment Cause..... | 76 | +| 58 | A.14.8 Number of RRC connection completions for initial RRC Connection requests each Establishment Cause ..... | 77 | +| 59 | A.14.9 Number of retransmission RRC Connections requests each Establishment Cause ..... | 78 | +| 60 | A.14.10 Number of RRC Connections completions for retransmission RRC Connections requests each | | +| 61 | Establishment Cause..... | 79 | + +| | | | +|----|---------------------------------------------------------------------------------------------------------------------|-----| +| 1 | A.14.11 Number of incomplete RRC Connection by failed resource allocations each Establishment Cause..... | 80 | +| 2 | A.14.12 Number of incomplete RRC Connection by O-CU internal error each Establishment Cause..... | 80 | +| 3 | A.15 Monitoring of Establishment calls for SA..... | 81 | +| 4 | A.15.1 Number of attempted establishment calls for mo-Data..... | 81 | +| 5 | A.15.2 Number of successful establishment calls for mo-Data..... | 82 | +| 6 | A.15.3 Number of incomplete establishment calls for mo-Data by protocol error..... | 82 | +| 7 | A.15.4 Number of incomplete establishment calls for mo-Data by O-CU internal error..... | 83 | +| 8 | A.15.5 Number of incomplete establishment calls for mo-Data by O-DU error detection..... | 83 | +| 9 | A.15.6 Number of attempted establishment calls for mt-Access..... | 83 | +| 10 | A.15.7 Number of successful establishment calls for mt-Access..... | 84 | +| 11 | A.15.8 Number of incomplete establishment calls for mt-Access by protocol error..... | 84 | +| 12 | A.15.9 Number of incomplete establishment calls for mt-Access by O-CU internal error..... | 85 | +| 13 | A.15.10 Number of incomplete establishment calls for mt-Access by O-DU error detection..... | 85 | +| 14 | A.15.11 Number of attempted establishment calls for mo-Signalling..... | 85 | +| 15 | A.15.12 Number of successful establishment calls for mo-Signalling..... | 86 | +| 16 | A.15.13 Number of incomplete establishment calls for mo-Signalling by protocol error..... | 86 | +| 17 | A.15.14 Number of incomplete establishment calls for mo-Signalling by O-CU internal error..... | 87 | +| 18 | A.15.15 Number of incomplete establishment calls for mo-Signalling by O-DU error detection..... | 87 | +| 19 | A.15.16 Number of attempted establishment calls for mo-SMS..... | 88 | +| 20 | A.15.17 Number of successful establishment calls for mo-SMS..... | 88 | +| 21 | A.15.18 Number of incomplete establishment calls for mo-SMS by protocol error..... | 89 | +| 22 | A.15.19 Number of incomplete establishment calls for mo-SMS by O-CU internal error..... | 89 | +| 23 | A.15.20 Number of incomplete establishment calls for mo-SMS by O-DU error detection..... | 89 | +| 24 | A.15.21 Number of attempted establishment calls for high priority access..... | 90 | +| 25 | A.15.22 Number of successful establishment calls for high priority access..... | 90 | +| 26 | A.15.23 Number of incomplete establishment calls for high priority access by protocol error..... | 91 | +| 27 | A.15.24 Number of incomplete establishment calls for high priority access by O-CU internal error..... | 91 | +| 28 | A.15.25 Number of incomplete establishment calls for high priority access by O-DU error detection..... | 92 | +| 29 | A.15.26 Number of attempted establishment calls for emergency..... | 92 | +| 30 | A.15.27 Number of successful establishment calls for emergency..... | 92 | +| 31 | A.15.28 Number of incomplete establishment calls for emergency by protocol error..... | 93 | +| 32 | A.15.29 Number of incomplete establishment calls for emergency by O-CU internal error..... | 93 | +| 33 | A.15.30 Number of incomplete establishment calls for emergency by O-DU error detection..... | 94 | +| 34 | A.15.31 Discarded paging records..... | 94 | +| 35 | A.16 Monitoring of PDU session connection for SA..... | 95 | +| 36 | A.16.1 Accepted PDU Session Resource Configuration..... | 95 | +| 37 | A.16.2 Completed PDU Session Resource Configuration..... | 95 | +| 38 | A.16.3 Interrupted PDU Session Resource configuration by Protocol Error..... | 96 | +| 39 | A.16.4 Interrupted PDU Session Resource configuration by O-DU Error Detection..... | 96 | +| 40 | A.16.5 Interrupted PDU Session Resource configuration by O-CU internal error..... | 97 | +| 41 | A.16.6 Accepted PDU Session Resource Configuration for emergency and high priority access..... | 98 | +| 42 | A.16.7 Completed PDU Session Resource Configuration for emergency and high priority access..... | 98 | +| 43 | A.16.8 Interrupted PDU Session Resource configuration for emergency and high priority access by Protocol Error..... | 99 | +| 44 | A.16.9 Interrupted PDU Session Resource configuration for emergency and high priority access by O-DU Error | | +| 45 | Detection..... | 100 | +| 46 | A.16.10 Interrupted PDU Session Resource configuration for emergency and high priority access by O-CU | | +| 47 | internal Error..... | 100 | +| 48 | A.17 Monitoring of mobility for SA..... | 101 | +| 49 | A.17.1 Accepted Handover..... | 101 | +| 50 | A.17.2 Completed Handover..... | 102 | +| 51 | A.17.3 Accepted Inter RAT Handover to LTE..... | 102 | +| 52 | A.17.4 Completed Inter RAT Handover to LTE..... | 102 | +| 53 | A.17.5 Accepted EPS Fallback..... | 103 | +| 54 | A.17.6 Completed EPS Fallback..... | 103 | +| 55 | A.17.7 Normal interrupted EPS Fallback..... | 104 | +| 56 | A.17.8 Accepted Handover during Voice call..... | 104 | +| 57 | A.17.9 Completed Handover during Voice call..... | 104 | +| 58 | A.17.10 Accepted Inter RAT Handover to LTE during Voice call..... | 105 | +| 59 | A.17.11 Completed Inter RAT Handover to LTE during Voice call..... | 105 | +| 60 | A.18 Monitoring of RRC re-establishment for SA..... | 106 | +| 61 | A.18.1 Number of initial RRC re-establishment requests when UE context can be retrieved..... | 106 | + +| | | | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| A.18.2 | Number of RRC re-establishment request completions for initial RRC re-establishment requests when UE context can be retrieved ..... | 106 | +| A.18.3 | Number of retransmission RRC re-establishment requests when UE context can be retrieved..... | 107 | +| A.18.4 | Number of RRC re-establishment request completions for retransmission RRC re-establishment request when UE context can be retrieved ..... | 107 | +| A.18.5 | Number of initial RRC re-establishment requests when UE context cannot be retrieved..... | 107 | +| A.18.6 | Number of RRC re-establishment request completions for initial RRC re-establishment requests when UE context cannot be retrieved..... | 108 | +| A.18.7 | Number of retransmission RRC re-establishment requests when UE context cannot be retrieved ..... | 108 | +| A.18.8 | Number of RRC re-establishment request completions for retransmission RRC re-establishment requests when UE context cannot be retrieved ..... | 109 | +| A.18.9 | Number of initial RRC re-establishment requests during Voice call when UE context can be retrieved ..... | 109 | +| A.18.10 | Number of RRC re-establishment request completions for initial RRC re-establishment requests during Voice call when UE context can be retrieved..... | 110 | +| A.18.11 | Number of retransmission RRC re-establishment requests during Voice call when UE context can be retrieved ..... | 110 | +| A.18.12 | Number of RRC re-establishment request completions for retransmission RRC re-establishment request during Voice call when UE context can be retrieved..... | 111 | +| A.19 | Monitoring of connection status for SA ..... | 111 | +| A.19.1 | Normally Released Calls ..... | 111 | +| A.19.2 | Abnormally Released Calls ..... | 111 | +| A.19.3 | Another Cell HO UE Contexts ..... | 112 | +| A.19.4 | Normally Released Calls during voice call..... | 112 | +| A.19.5 | Abnormally Released Calls during voice call..... | 113 | +| A.19.6 | Another Cell HO UE Contexts during voice call..... | 113 | +| A.20 | Monitoring of procedure for NR-DC ..... | 114 | +| A.20.1 | Number of S-NG-RAN Node Addition procedure attempted for each Cell ..... | 114 | +| A.20.2 | Number of S-NG-RAN Node Addition procedure successfully for each Cell..... | 114 | +| A.20.3 | Number of S-NG-RAN Node Addition procedure attempted for each neighbour gNB ..... | 114 | +| A.20.4 | Number of S-NG-RAN Node Addition procedure successfully for each neighbour gNB..... | 115 | +| A.20.5 | Number of S-NG-RAN Node modification procedure attempted for each Cell ..... | 116 | +| A.20.6 | Number of S-NG-RAN Node modification procedure successfully for each Cell..... | 116 | +| A.20.7 | Number of S-NG-RAN Node modification procedure attempted for each neighbour gNB ..... | 117 | +| A.20.8 | Number of S-NG-RAN Node modification procedure successfully for each neighbour gNB..... | 117 | +| A.20.9 | Number of S-NG-RAN Node Release procedure attempted for each Cell..... | 118 | +| A.20.10 | Number of S-NG-RAN Node Release procedure successfully for each Cell ..... | 118 | +| A.20.11 | Number of S-NG-RAN Node Release procedure attempted for each neighbour gNB ..... | 119 | +| A.20.12 | Number of S-NG-RAN Node Release procedure successfully for each neighbour gNB ..... | 119 | +| A.20.13 | Number of SCGFailureInformation received..... | 120 | +| A.21 | Monitoring of CA for SA ..... | 120 | +| A.21.1 | Number of SCell Addition procedure attempted..... | 120 | +| A.21.2 | Number of SCell Addition procedure successfully ..... | 120 | +| A.21.3 | Number of SCell Change procedure attempted ..... | 121 | +| A.21.4 | Number of SCell Change procedure successfully ..... | 121 | +| A.21.5 | Number of SCell Deletion procedure attempted ..... | 122 | +| A.21.6 | Number of SCell Deletion procedure successfully ..... | 122 | +| Revision History | ..... | 123 | + +## List of Figures + +| | | | +|--------------|-------------------------------------------------------------------|----| +| Figure 6-1: | Heartbeat Notification ..... | 11 | +| Figure 10-1: | File Ready Notification..... | 15 | +| Figure 11-1: | Containment for SecurityHandling and CUCountGroup ..... | 18 | +| Figure 11-2: | Containment for PDCCPConfig ..... | 19 | +| Figure 11-3: | Inheritance for CUCountGroup, SecurityHandling, PDCCPConfig ..... | 20 | + +--- + +## List of Tables + +| | | +|-----------------------------------------------------------------|----| +| Table 1: Parameters list for Notification notifyFileReady ..... | 14 | +|-----------------------------------------------------------------|----| + +--- + +## Foreword + +This Technical Specification (TS) has been produced by WG5 of the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN WG5 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit is included only in working versions of the document indicating incremental changes during the editing process. + +--- + +## Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are NOT allowed in O-RAN deliverables except when used in direct citation. + +# 1 Scope + +The present document specifies the O1 Interface specification for O-CU used over the interface linking the O-CU (O-RAN Central Unit) with Service Management and Orchestration (SMO). + +## 2 References + +### 2.1 Normative references + +References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document. + +The following referenced documents are necessary for the application of the present document. + +- [1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”, Release 17, v17.0.0, 2020-07 +- [2] O-RAN-WG10.OAM-Architecture-v09.00, O-RAN Alliance, Working Group 10 +- [3] O-RAN.WG10.O1-Interface.0-v10.00, “O-RAN Operations and Maintenance Interface Specification”, O-RAN Alliance, Working Group 10 +- [4] 3GPP TS 28.541, “Management and orchestration; 5G Network Resource Model (NRM); Stage 2 and stage 3”, Release 17, v17.2.1, 2021-04 +- [5] 3GPP TS 32.342, “File Transfer (FT); Integration Reference Point (IRP); Information Service (IS)”, Release 16, v16.0.0, 2020-07 +- [6] 3GPP TS 32.302, “Configuration Management (CM); Notification Integration Reference Point (IRP) ; Information Service (IS)”, Release 16, v16.0.0, 2020-07 +- [7] 3GPP TS 28.622, “Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS)”, Release 16, v16.7.1, 2021-04 +- [8] 3GPP TS 28.552: “Management and orchestration; 5G performance measurements”, Release 17, v17.4.0, 2021-09 +- [9] 3GPP TS 32.156: “Telecommunication management; Fixed Mobile Convergence (FMC) Model repertoire”, 3GPP, Release 17, v17.1.0, 2022-06 +- [10] 3GPP TS 32.160: “Management and orchestration; Management service template”, 3GPP, Release 17, v17.4.0, 2022-06 +- [11] 3GPP TS 38.401: “NG-RAN; Architecture description”, 3GPP, Release 17, v17.1.1, 2022-07 +- [12] 3GPP TS 38.331: “NR; Radio Resource Control (RRC); Protocol specification”, 3GPP, Release 17 +- [13] 3GPP TS 38.463: “NG-RAN; E1 Application Protocol (E1AP)”, 3GPP, Release 17 + +### 2.2 Informative references + +References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +## 3 Definitions of terms symbols and abbreviations + +### 3.1 Terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the O1 interface specification [3] apply. + +### 3.2 Symbols + +For the purposes of the present document, the symbols given in 3GPP TR 21.905 [1] and the following apply. A symbol defined in the present document takes precedence over the definition of the same symbol, if any, in 3GPP TR 21.905 [1]. + +### 3.3 Abbreviations and acronyms + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [1]. + +| | | +|---------|-------------------------------------------------------------| +| 5QI | 5G QoS Identifier | +| MnS | Management Service | +| NETCONF | Network Configuration Protocol | +| NMS | Network Management System | +| O-CU | O-RAN Central Unit | +| O-CU-CP | O-RAN Central Unit Control Plane | +| O-CU-UP | O-RAN Central Unit User Plane | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| OAM | Operations And Maintenance | +| PNF | Physical Network Function | +| QoS | Quality of Service | +| RPC | Remote Procedure Call | +| sFTP | Secure File Transfer Protocol or SSH File Transfer Protocol | +| SMO | Service Management and Orchestration | +| SSH | Secure Shell | +| VES | Virtual-function Event Streaming | +| VLAN | Virtual LAN | +| YANG | Yet Another Next Generation | + +### 3.4 Conventions + +This specification includes cross references to a set of associated YANG models. Text may reference particular YANG leafs, notifications and remote procedure calls (RPCs). In order to assist in readability, all cross references to YANG defined elements will keep the identical case format as defined in the corresponding YANG model, with the font-weight set to **bold**. This convention applies only to text and not to YANG elements embedded into figures. + +If there is any conflict between the YANG models and the accompanying text description in this specification, the definition of the YANG models shall take precedence. + +## 3.5 Revision and compatibility handling + +The revision statement in the YANG models shall be used to describe future revisions to the models that are backwards compatible. Backwards incompatible changes will be addressed by incrementing the number used as part of the model name and namespace, effectively creating a new YANG model. The format of the namespace used in all O-RAN YANG models is “urn:o-ran:”<model-name>“:”<model-number>, where the initial <model-number> used in a newly defined YANG model is “1.0”. Where this document makes reference to models, irrespective of their backward compatibility, a generic <model-number> of “x.y” is used to enable reference to all versions of the namespace for a particular <model-name>. + +The revision statement in all YANG models includes a reference statement used to cross-reference to the first version of this document where the corresponding description was introduced. For example, the reference in all revision statements for the initial O-RAN models should include cross-reference to “O-RAN.WG5.O-CU-O1.0-v01.00”. + +The revision statement of the YANG models also includes a description which is used to track the versioning of the YANG model. All revision statement descriptions will begin with “version ”<a>“.”<b>“.”<c>, where <a>, <b> and <c> are used to reflect the version of the YANG model, where + +- <a> corresponds to the first digit of the O-RAN WG5 management plane specification version where the corresponding description was first introduced, corresponding to <x> in clause 1 +- <b> is incremented when errors in the YANG model have been corrected +- <c> is incremented only in working versions of the YANG model indicating incremental changes during the editing process + +## 4 High Level Description + +### 4.1 Top level functional description and terminology + +#### 4.1.1 Architecture for O-RAN WG5 functional split + +This O1 interface facilitates the initialization, configuration and management of the O-CU-CP and O-CU-UP. Please refer to O-RAN OAM Architecture [2] for more details on the architecture. + +#### 4.1.2 O1 interface for O-CU architecture model + +O1 interface for O-CU-CP and O-CU-UP is used for supporting the management features including “start up” installation, PNF software management, provisioning management, performance management, fault management and file management towards the O-CU. + +#### 4.1.3 Transport Network + +Based on the transport topology, various modes of network connectivity are possible between O-CU-CP, O-CU-UP and SMO, as defined in the O-RAN OAM Architecture document [2]. + +### 4.2 Interfaces + +The interface between the management system and the O-CU is as defined in the O1 specification [3]. + +## 5 PNF Startup and Registration Management + +O-CU (including O-CU-CP and O-CU-UP) may be deployed as PNF as described in O1 Interface Specification [3], clause 6.7 PNF Startup and Registration Management Services. + +### 5.1 PNF Plug-n-Play + +PNF Plug-n-Play for O-CU is aligned with O1 Interface Specification [3], clause 6.7.1 PNF Plug-n-Connect. + +### 5.2 PNF Registration + +PNF Registration for O-CU is aligned with O1 Interface Specification [3], clause 6.7.2 PNF Registration. + +## 6 Heartbeat Management Services + +### 6.1 Heartbeat Notification + +Heartbeat Notification for both O-CU-CP and O-CU-UP are aligned with O1 Interface Specification [3], clause 6.6.1 Heartbeat Notification. Figure 6-1 shows the example of notifyHeartbeat notification by using ‘SDO O1 format’. + +![Sequence diagram showing notifyHeartbeat notification flow between SMO/OAM (MnS Consumer), O-CU-CP (MnS Provider), and O-CU-UP (MnS Provider). The diagram shows two instances of the entities. In the first instance, O-CU-CP triggers a 'When Heartbeat VES event is triggered' event, which leads to a 'notifyHeartbeat notification' message being sent to SMO/OAM. In the second instance, O-CU-UP triggers a 'When Heartbeat VES event is triggered' event, which leads to a 'notifyHeartbeat notification' message being sent to SMO/OAM.](5c38e6d0d65b9c37b41b734c20e6dc34_img.jpg) + +**notifyHeartbeat notification** + +``` + +sequenceDiagram + participant SMO as SMO/OAM (MnS Consumer) + participant OCU_CP as O-CU-CP (MnS Provider) + participant OCU_UP as O-CU-UP (MnS Provider) + + Note over OCU_CP: When Heartbeat VES event is triggered + OCU_CP->>SMO: notifyHeartbeat notification + + Note over OCU_UP: When Heartbeat VES event is triggered + OCU_UP->>SMO: notifyHeartbeat notification + +``` + +Sequence diagram showing notifyHeartbeat notification flow between SMO/OAM (MnS Consumer), O-CU-CP (MnS Provider), and O-CU-UP (MnS Provider). The diagram shows two instances of the entities. In the first instance, O-CU-CP triggers a 'When Heartbeat VES event is triggered' event, which leads to a 'notifyHeartbeat notification' message being sent to SMO/OAM. In the second instance, O-CU-UP triggers a 'When Heartbeat VES event is triggered' event, which leads to a 'notifyHeartbeat notification' message being sent to SMO/OAM. + +**Figure 6-1: Heartbeat Notification** + +### 6.2 Heartbeat Control + +Heartbeat Control for both O-CU-CP and O-CU-UP are aligned with O1 Interface Specification [3], clause 6.6.2 Heartbeat Control. + +--- + +## 7 PNF Software Management Services + +### 7.1 Software Package Naming and Content + +Software Package Naming and Content for O-CU is aligned with O1 Interface Specification [3], clause 6.8.1 Software Package Naming and Content. + +### 7.2 Software Inventory + +Software Inventory for O-CU is aligned with O1 Interface Specification [3], clause 6.8.2 Software Inventory. + +### 7.3 Software Download + +Software Download for O-CU is aligned with O1 Interface Specification [3], clause 6.8.3 Software Download. + +### 7.4 Software Activation Pre-Check + +Software Activation Pre-Check for O-CU is aligned with O1 Interface Specification [3], clause 6.8.4 Software Activation Pre-Check. + +### 7.5 Software Activate + +Software Activate for O-CU is aligned with O1 Interface Specification [3], clause 6.8.5 Software Activate. + +--- + +## 8 Performance Management + +### 8.1 Performance Data File Reporting + +Performance Data File Reporting for O-CU is aligned with O1 Interface Specification [3], clause 6.3.1 Performance Data File Reporting. + +The Measurement Type and definitions for performance counters are described in both clause 6.3 of O1 interface specification [3] and Annex A of this specification. All measurements are optional and can be selected based on service deployment. + +### 8.2 Performance Data Streaming + +Performance Data Streaming for O-CU is aligned with O1 Interface Specification [3], clause 6.3.2 Performance Data Streaming. + +### 8.3 Measurement Job Control + +Measurement Job Control for O-CU is aligned with O1 Interface Specification [3], clause 6.3.3 Measurement Job Control. + +## 9 Fault Management + +Fault supervision management services allow a Fault Supervision MnS Provider to report errors and events to a Fault Supervision MnS Consumer and allow a Fault Supervision MnS Consumer to perform fault supervision operations on the Fault Supervision MnS Provider, such as get alarm list. + +O-CU-UP and O-CU-CP Fault Supervision Management services are aligned with O1 Interface Specification [3], clause 6.2 Fault Supervision Management Services. + +### 9.1 Fault Notification + +O-CU-UP and O-CU-CP Fault notification events are aligned with O1 Interface Specification [3], clause 6.2.1 Fault Notification. + +### 9.2 Fault Supervision Control + +O-CU-UP and O-CU-CP Fault supervision control is aligned with O1 Interface Specification [3], clause 6.2.2 Fault Supervision Control. + +## 10 File Management + +This clause illustrate File Management between the O-CU-CP and SMO and between the O-CU-UP and SMO. The File Management Service is applied to manage file transfer for different types of data file such as Bulk CM file, Call and UE trace file, Performance Measurement result file, etc. The following file management use cases are supported for the O-CU-CP and O-CU-UP: + +- List available files +- Transfer file +- Download file +- File ready notification + +The detailed description of the use cases including file management operations and procedures as well as sequence diagram can be found in the O-RAN O1 interface specification [3], clause 6.5. + +This clause shall describe the handling of files that are stored in the O-CU-CP which are generated by the O-CU-CP itself and O-CU-UP which are generated by the O-CU-UP itself. + +The data files that are stored in the O-CU shall follow clause 10.1 of this specification. + +### 10.1 File Structure + +The file system structure for the O-CU-CP and O-CU-UP is defined as for file management procedures defined in the rest of this clause. If the O-CU-CP and O-CU-UP's physical file structure differs from the logical file structure defined below, the O-CU-CP and O-CU-UP shall perform the mapping related files into defined structure. + +The O-CU-CP and O-CU-UP shall support the standardized folders for files generated by the O-CU-CP and O-CU-UP itself. The following standardized folders are defined: + +## O-CU-CP + +- › O-RAN/O-CU-CP/PM/ for performance data files +- › O-RAN/O-CU-CP/CM/ for configuration files (except inventory) +- › O-RAN/O-CU-CP/NL/ for notification log file +- › O-RAN/O-CU-CP/CT/ for call trace files +- › O-RAN/O-CU-CP/OT/ for other files + +## O-CU-UP + +- › O-RAN/O-CU-UP/PM/ for performance data files +- › O-RAN/O-CU-UP/CM/ for configuration files (except inventory) +- › O-RAN/O-CU-UP/NL/ for notification log file +- › O-RAN/O-CU-UP/CT/ for call trace files +- › O-RAN/O-CU-UP/OT/ for other files + +The O-CU-CP and O-CU-UP may additionally support vendor defined folders which are out of scope of this specification. + +## 10.2 Notification notifyFileReady + +The file ready notification is applied to when the management data files have been prepared ready in O-CU-CP and O-CU-UP. The O-CU-CP and O-CU-UP will send notification using notifyFileReady VES event to subscribed SMO in order to notify the availability of the file(s) as defined in O1 Interface Specification [3]. + +The following input parameters are provided by the file ready notification (see also 3GPP TS 32.342 [5]): + +| | | +|------------------|-----------------------------------------------------------------------------------| +| objectClass | Notification header – see 3GPP TS 32.302[6]. It shall carry the FTIRP class name. | +| objectInstance | Notification header - see 3GPP TS 32.302[6]. It shall carry the DN of the FTIRP. | +| notificationId | Notification header - see 3GPP TS 32.302[6] . | +| eventTime | Notification header - see 3GPP TS 32.302[6] . | +| systemDN | Notification header - see 3GPP TS 32.302[6] . | +| notificationType | Notification header – see 3GPP TS 32.302[6] . | +| fileInfoList | It specifies the information of the available file. | +| additionalText | It carries vendor-specific semantics not defined in the present document. | + +**Table 1: Parameters list for Notification notifyFileReady** + +When a file is available, the O-CU-CP and O-CU-UP sends a FileReady notification to the SMO using HTTP/TLS as defined in O1 Interface Specification [3]. The FileReady notification for O-CU-CP and O-CU-UP is performed independently. + +``` +@startuml +Title File Ready Notification +participant "SMO/OAM\n(File Management Service Consumer)" as L +participant "O-CU-CP\n(File Management Service Provider)" as M +participant "O-CU-UP\n(File Management Service Provider)" as N +note over ME : New file is available +``` + +``` + +1 L <- M: HTTP/TLS<notifyFileReady> +2 note over N: New file is available +3 L <- N: HTTP/TLS<notifyFileReady> +4 @enduml + +``` + +![Sequence diagram showing File Ready Notification between SMO/OAM, O-CU-CP, and O-CU-UP.](4b1dc0ee1de25091d491adb41b78cff6_img.jpg) + +**File Ready Notification** + +``` + +sequenceDiagram + participant SMO as SMO/OAM +(File Management Service Consumer) + participant OCUCP as O-CU-CP +(File Management Service Provider) + participant OCUP as O-CU-UP +(File Management Service Provider) + + OCUCP-->>SMO: HTTP/TLS<notifyFileReady> + OCUP-->>SMO: HTTP/TLS<notifyFileReady> + +``` + +The diagram illustrates the File Ready Notification process. It shows three entities: SMO/OAM (File Management Service Consumer), O-CU-CP (File Management Service Provider), and O-CU-UP (File Management Service Provider). O-CU-CP and O-CU-UP both send HTTP/TLS<notifyFileReady> messages to SMO/OAM. A note 'New file is available' is placed above the O-CU-CP message, and another note 'New file is available' is placed above the O-CU-UP message. + +Sequence diagram showing File Ready Notification between SMO/OAM, O-CU-CP, and O-CU-UP. + +**Figure 10-1: File Ready Notification** + +## 10.3 File Management Operation: listAvailableFiles + +This listAvailableFiles operation for the SMO is applied to obtain the available file list with files location and type from the O-CU-CP and O-CU-UP by reading the AvailableFileList IOC as specified in O1 Interface Specification [3], clause 6.5.2. The listAvailableFiles operation for O-CU-CP and O-CU-UP can be performed independently. + +## 10.4 File Management Operation: transferFile + +The Transfer File Service provides the capability for the SMO to transfer files from or to the O-CU-CP and O-CU-UP. SMO/OAM may perform this action as a result of a FileReady notification from the O-CU-CP and O-CU-UP informing SMO that a file is now available to transfer. In any case, the file transfer is performed using a secure file transfer protocol (SFTP or FTPeS) from or to the location provided by O-CU-CP and O-CU-UP. The SMO triggers file transfer operation to O-CU-CP and O-CU-UP. Detailed procedure can be found in clause 6.5.3 of O1 Interface Specification [3]. The transferFile operation for O-CU-CP and O-CU-UP is performed independently. + +## 10.5 File Management Operation: downloadFile + +The Download File Service provides the capability for the SMO to request the O-CU-CP and O-CU-UP to download the file(s) when the SMO has a file that needs to be downloaded. In any case, the file download is performed using a secure file transfer protocol (SFTP or FTPeS) from the location provided by the SMO. The O-CU-CP and O-CU-UP replies to the SMO with the result of the download procedure. Detailed procedure can be found in clause 6.5.4 of O1 Interface Specification [3]. The downloadFile operation for O-CU-CP and O-CU-UP is performed independently. + +# 11 Provisioning Management + +This clause describes the Provisioning Management for O-CU specific aspects. + +## 11.1 Configuration for O-CU + +SMO configures the O-CU-CP and O-CU-UP. + +Data Model configurations: + +### 1. SA5 data model + +The following 3GPP SA5 YANG modules are imported in the O-CU YANG modules published along with this specification. See TS 28.541 [4] + +- \_3gpp-common-top.yang + +- \_3gpp-common-yang-types.yang + +- \_3gpp-common-managed-element.yang + +- \_3gpp-nr-nrm-gnbcucpfunction.yang + +- \_3gpp-nr-nrm-nrcellcu.yang + +- \_3gpp-nr-nrm-nrfreqrelation.yang + +- \_3gpp-nr-nrm-gnbcuupfunction.yang + +- \_3gpp-nr-nrm-ep.yang + +### 2. O-RAN augmentation of SA5 data models + +#### O-CU-CP + +- o-ran-cu-security-handling.yang + +#### O-CU-UP + +--- + +The O-CU YANG modules listed above, are published along with this specification document, and augment SA5 data models. + +*SupportQualifier*(SQ) property for each attribute in the O-CU YANG modules, specifies whether it is mandatory for vendor to support the attribute in the implementation and in the data model. Meaning of this property, follows the definition in 3GPP TS 32.156 [9], clause 6. Values can be M, O, CM, CO. + +If SQ=O, for an attribute, and if vendor does not support it, then this lack of support shall be indicated, as specified in 3GPP TS 32.160 [10] clause 6.2.26. + +If SQ is not specified, then a default value of 'O' is to be assumed. + +## 11.2 Notification aspect + +### 11.2.1 Subscribing for O-CU notification from SMO + +The O-CU would represent the parameters in its YANG model. + +The SMO is responsible of subscribing to the parameters of interest from the O-CU data model using subscription mechanism described in O1 Interface specification [3] clause 6.1.7 Subscription Control. + +## 11.3 Information model for O-CU-CP + +### 11.3.1 Imported and associated information entities + +#### 11.3.1.1 Imported information entities and local labels + +| Label reference | Local label | +|------------------------------|-------------| +| 3GPP TS 28.622 [7], IOC, Top | Top | + +#### 11.3.1.2 Accociated information entities and local labels + +| Label reference | Local label | +|-----------------------------------------|----------------| +| 3GPP TS 28.622 [7], IOC, ManagedElement | ManagedElement | + +### 11.3.2 Class diagram + +#### 11.3.2.1 Relationships + +``` + +@startuml +skin rose +Class ManagedElement <<InformationObjectClass>> <<(A, CadetBlue)>> +Class GNBCUCPFunction <<InformationObjectClass>> <<(L, #FF7700)>> + +class SecurityHandling <<InformationObjectClass>> <<(L, #FF7700)>> +SecurityHandling : <color:Blue> cipheringAlgoPrio </color> +SecurityHandling : <color:Blue> integrityProtectAlgoPrio </color> + +class CUCountGroup <<InformationObjectClass>> <<(L, #FF7700)>> +CUCountGroup : <color:Blue> cu-count-group-index </color> +CUCountGroup : <color:Blue> drb-id </color> +CUCountGroup : <color:Blue> qci </color> +CUCountGroup : <color:Blue> srb-id </color> +CUCountGroup : <color:Blue> fiveQi </color> +CUCountGroup : <color:Blue> sd </color> +CUCountGroup : <color:Blue> sst </color> +CUCountGroup : <color:Blue> plmn-id </color> +CUCountGroup : <color:Blue> arp </color> + +ManagedElement *-- "0..*" GNBCUCPFunction +GNBCUCPFunction *-- "0..1" SecurityHandling +GNBCUCPFunction *-- "0..30" CUCountGroup +@enduml + +``` + +![UML Class Diagram showing containment relationships between ManagedElement, GNBCUCPFunction, SecurityHandling, and CUCCountGroup.](40e7a1737a6eb186da4bfc2c909de095_img.jpg) + +``` + +classDiagram + class ManagedElement["«InformationObjectClass» ManagedElement"] + class GNBCUCPFunction["«InformationObjectClass» GNBCUCPFunction"] + class SecurityHandling["«InformationObjectClass» SecurityHandling"] + class CUCCountGroup["«InformationObjectClass» CUCCountGroup"] + + ManagedElement "0..*" --> "1" GNBCUCPFunction + GNBCUCPFunction "0..1" --> "1" SecurityHandling + GNBCUCPFunction "0..30" --> "1" CUCCountGroup + +``` + +The diagram illustrates the containment structure for SecurityHandling and CUCCountGroup. ManagedElement (a generalization of InformationObjectClass) contains GNBCUCPFunction (also a generalization of InformationObjectClass) with a multiplicity of 0..\*. GNBCUCPFunction contains SecurityHandling (a generalization of InformationObjectClass) with a multiplicity of 0..1. Additionally, GNBCUCPFunction contains CUCCountGroup (a generalization of InformationObjectClass) with a multiplicity of 0..30. The CUCCountGroup class lists attributes: cu-count-group-index, drb-id, qci, srb-id, fiveQi, sd, sst, plmn-id, and arp. + +UML Class Diagram showing containment relationships between ManagedElement, GNBCUCPFunction, SecurityHandling, and CUCCountGroup. + +Figure 11-1: Containment for SecurityHandling and CUCCountGroup + +``` + +@startuml +skin rose + +class GNBCUCPFunction <<InformationObjectClass>> + +class "PDCPConfig" <<InformationObjectClass>> +"PDCPConfig" : qci +"PDCPConfig" : fiveQI +"PDCPConfig" : discard-timer +"PDCPConfig" : pdcp-sn-size-ul +"PDCPConfig" : pdcp-sn-size-dl +"PDCPConfig" : t-reordering +"PDCPConfig" : t-reordering-ul +"PDCPConfig" : rlc-mode +"PDCPConfig" : header-compression-enabled +"PDCPConfig" : ul-data-split-threshold + +GNBCUCPFunction *-- "0..32" "PDCPConfig" : <<names>> + +@enduml + +``` + +![UML Class Diagram showing containment for PDCPConfig. The top class is «InformationObjectClass» GNBCUCPFunction. The bottom class is «InformationObjectClass» PDCPConfig. PDCPConfig contains GNBCUCPFunction with a multiplicity of 0..32 and the role «names».](2daabaa1a191eb1be4ee824ba5c1205b_img.jpg) + +``` + +classDiagram + class GNBCUCPFunction { + <<InformationObjectClass>> + } + class PDCPConfig { + <<InformationObjectClass>> + qci + fiveQI + discard-timer + pdcp-sn-size-ul + pdcp-sn-size-dl + t-reordering + t-reordering-ul + rlc-mode + header-compression-enabled + ul-data-split-threshold + } + GNBCUCPFunction "0..32" *-- "1" PDCPConfig : «names» + +``` + +UML Class Diagram showing containment for PDCPConfig. The top class is «InformationObjectClass» GNBCUCPFunction. The bottom class is «InformationObjectClass» PDCPConfig. PDCPConfig contains GNBCUCPFunction with a multiplicity of 0..32 and the role «names». + +Figure 11-2: Containment for PDCPConfig + +### 11.3.2.2 Inheritance + +``` + +@startuml +skin rose +skinparam ClassStereotypeFontStyle normal +skinparam style strictuml +hide empty members +abstract class Top <<InformationObjectClass>> +class CUCCountGroup <<InformationObjectClass>> +Top <|-- CUCCountGroup +class SecurityHandling <<InformationObjectClass>> +Top <|-- SecurityHandling +class "PDCPConfig" <<InformationObjectClass>> +Top <|-- "PDCPConfig" +note right of Top + defined in + 3GPP TS 28.622 + clause 4.3.29 +end note +@enduml + +``` + +![UML class diagram showing inheritance for InformationObjectClass. The diagram shows three subclasses: CUCountGroup, SecurityHandling, and PDCPConfig, all inheriting from a base class Top. A note indicates that Top is defined in 3GPP TS 28.622 clause 4.3.29.](b4f9cbdd0137e28a2c6a5f8c258dc4bb_img.jpg) + +``` + +classDiagram + class Top["«InformationObjectClass»\nTop"] + class CUCountGroup["«InformationObjectClass»\nCUCountGroup"] + class SecurityHandling["«InformationObjectClass»\nSecurityHandling"] + class PDCPConfig["«InformationObjectClass»\nPDCPConfig"] + Top <|-- CUCountGroup + Top <|-- SecurityHandling + Top <|-- PDCPConfig + +``` + +defined in 3GPP TS 28.622 clause 4.3.29 + +UML class diagram showing inheritance for InformationObjectClass. The diagram shows three subclasses: CUCountGroup, SecurityHandling, and PDCPConfig, all inheriting from a base class Top. A note indicates that Top is defined in 3GPP TS 28.622 clause 4.3.29. + +Figure 11-3: Inheritance for CUCountGroup, SecurityHandling, PDCPConfig + +### 11.3.3 Class definition + +#### 11.3.3.1 SecurityHandling <<InformationObjectClass>> + +##### 11.3.3.1.1 Definition + +This IOC represents the CU-CP security related handling function. + +##### 11.3.3.1.2 Attributes + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|--------------------------|-------------------|------------|------------|-------------|--------------| +| cipheringAlgoPrio | O | T | T | F | T | +| integrityProtectAlgoPrio | O | T | T | F | T | + +##### 11.3.3.1.3 Attribute constraints + +None + +##### 11.3.3.1.4 Notifications + +There are no notifications defined. + +##### 11.3.3.1.5 State diagram + +None + +#### 11.3.3.2 CUCountGroup <<InformationObjectClass>> + +##### 11.3.3.2.1 Definition + +This IOC represents the cucountgroup function. + +### 11.3.3.2.2 Attributes + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|----------------------|-------------------|------------|------------|-------------|--------------| +| cu-count-group-index | O | T | T | F | T | +| drb-id | O | T | T | F | T | +| qci | O | T | T | F | T | +| srb-id | O | T | T | F | T | +| fiveQI | O | T | T | F | T | +| sd | O | T | T | F | T | +| sst | O | T | T | F | T | +| plmn-id | O | T | T | F | T | +| arp | O | T | T | F | T | + +### 11.3.3.2.3 Attribute constraints + +None + +### 11.3.3.2.4 Notifications + +There are no notifications defined. + +### 11.3.3.2.5 State diagram + +None + +## 11.3.3.3 PDCCPConfig <<InformationObjectClass>> + +### 11.3.3.3.1 Definition + +This IOC represents PDCCP configurations for O-CU-CP. + +### 11.3.3.3.2 Attributes + +| Attribute name | Support Qualifier | isReadable | isWritable | isInvariant | isNotifiable | +|----------------------------|-------------------|------------|------------|-------------|--------------| +| qci | O | T | T | F | T | +| fiveQI | O | T | T | F | T | +| discard-timer | O | T | T | F | T | +| pdcp-sn-size-ul | O | T | T | F | T | +| pdcp-sn-size-dl | O | T | T | F | T | +| t-reordering | O | T | T | F | T | +| t-reordering-ul | O | T | T | F | T | +| rlc-mode | O | T | T | F | T | +| header-compression-enabled | O | T | T | F | T | +| ul-data-split-threshold | O | T | T | F | T | + +### 11.3.3.3.3 Attribute constraints + +None + +### 11.3.3.3.4 Notifications + +There are no notifications defined. + +### 11.3.3.3.5 State diagram + +None + +## 11.3.4 Attribute definitions + +### 11.3.4.1 Attribute properties + +| Attribute Name | Documentation and Allowed Values | Properties | +|---------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <code>cipheringAlgoPrio</code> | <p>The attribute provides allowed ciphering algorithms with priority order.</p> <p>Algorithm in index zero has highest priority. Each algorithm written only once in array.</p> <p>AllowedValues:<br/>NEA0, NEA1, NEA2, NEA3</p> <p>Default value:<br/>NEA1,NEA2,NEA0</p> | <p>Type: ENUM<br/>CipheringAlgorithmID<br/>multiplicity: 1..4<br/>isOrdered: True<br/>isUnique: True<br/>defaultValue: NEA1,NEA2,NEA0<br/>isNullable: False</p> | +| <code>integrityProtectAlgoPrio</code> | <p>The attribute provides allowed integrity algorithms with priority order.</p> <p>Algorithm in index zero has highest priority. Each algorithm written only once in array.</p> <p>AllowedValues:<br/>NIA1, NIA2, NIA3</p> <p>DefaultValue:<br/>NIA2,NIA1</p> | <p>Type: ENUM<br/>IntegrityAlgorithmID<br/>multiplicity: 1..3<br/>isOrdered: True<br/>isUnique: True<br/>defaultValue: NIA2,NIA1<br/>isNullable: False</p> | +| <code>cu-count-group-index</code> | <p>The attribute provides Cu Counter Group index.</p> <p>AllowedValues:<br/>0..30</p> | <p>Type: uint8<br/>multiplicity: 1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: -<br/>isNullable: False</p> | +| <code>drb-id</code> | <p>The attribute provides DRB ID which is used for concerned CuCountGroup. Value 0 indicates that this DRB ID is not counted in this CuCountGroup</p> <p>AllowedValues:<br/>0..32</p> | <p>Type: uint8<br/>multiplicity: 1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: -<br/>isNullable: False</p> | +| <code>CuCountGroup.qci</code> | <p>The attribute provides QoS Class Identifier defined in TS 23.401. Logical range and coding specified in TS 23.203. Value 0 indicates that this QCI shall NOT be counted in the CuCountGroup.</p> <p>AllowedValues:<br/>0..255</p> | <p>Type: uint8<br/>multiplicity: 1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: -<br/>isNullable: False</p> | +| <code>srb-id</code> | <p>The attribute provides SRB ID used for concerned CuCountGroup. Value 0 indicates that this SRB ID is not counted in this CuCountGroup.</p> <p>AllowedValues;<br/>0..3</p> | <p>Type: uint8<br/>multiplicity: 1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: -<br/>isNullable: False</p> | +| <code>CuCountGroup.fiveQI</code> | <p>The attribute provides 5QI identifier. Value 0 indicates that this 5QI shall NOT be counted in the CuCountGroup.</p> <p>AllowedValues;<br/>0..255</p> | <p>Type: uint8<br/>multiplicity: 1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: -<br/>isNullable: False</p> | + +| | | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------| +| sd | This parameter indicates the slice differentiator. Value 16777215 (0xFFFFF) means no SD value associated with the SST.<br><br>AllowedValues;<br>0..16777215 | Type: uint8<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: -<br>isNullable: False | +| sst | This parameter indicates the slice service type.<br><br>AllowedValues;<br>0..255 | Type: uint8<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: -<br>isNullable: False | +| plmn-id | 3-octet string, representing PLMN ID. | Type: string<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: -<br>isNullable: False | +| arp | This parameter indicates the allocation and retention priority. Value 0 indicates that this ARP is not counted in this CuCountGroup.<br><br>AllowedValues;<br>0..15 | Type: uint8<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: -<br>isNullable: False | +| PDCPConfig.qci | List of QCI for which this PDCP configuration is applied.<br><br>allowedValues: 0..255 | Type: Integer<br>multiplicity: 0..*<br>isOrdered: False<br>isUnique: True<br>defaultValue: -<br>isNullable: False | +| PDCPConfig.fiveQI | List of 5QIs for which this PDCP configuration is applied.<br><br>allowedValues: 0..255 | Type: Integer<br>multiplicity: 0..*<br>isOrdered: False<br>isUnique: True<br>defaultValue: -<br>isNullable: False | +| discard-timer | Discard timer in milliseconds for this PDCP Configuration. See TS 38.331 [12].<br><br>If no value set, implies infinity.<br><br>allowedValues: 10, 20, 30, 40, 50, 60, 75, 100, 150, 200, 250, 300, 500, 750, 1500 | Type: Integer<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: -<br>isNullable: False | +| pdcp-sn-size-ul | PDCP SN size in Uplink for this PDCP Configuration. Not used when rlc-mode set to RLC-TM. See TS 38.331 [12].<br><br>allowedValues: LEN-12-BITS, LEN-18-BITS | Type: ENUM pdcpSNSize<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: -<br>isNullable: False | +| pdcp-sn-size-dl | PDCP SN size in Downlink for this PDCP Configuration. Not used when rlc-mode set to RLC-TM. See TS 38.331 [12].<br><br>allowedValues: LEN-12-BITS, LEN-18-BITS | Type: ENUM pdcpSNSize<br>multiplicity: 1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: -<br>isNullable: False | +| t-reordering | Reordering timer in milliseconds for this PDCP Configuration. This timer is used by the receiving side of PDCP entity to detect loss of RLC PDUs at lower layer. See TS 38.331 [12].<br><br>If no value set, implies infinity.<br><br>allowedValues: 0, 1, 2, 4, 5, 8, 10, 15, 20, 30, 40, 50, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 500, 750, 1000, 1250, 1500, 1750, 2000, 2250, 2500, 2750, 3000 | Type: Integer<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: -<br>isNullable: False | + +| | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------| +| t-reordering-ul | <p>Uplink Reordering Timer in milliseconds for this PDCP Configuration. Used by CU-UP for Uplink. See TS 38.463 [13].</p> <p>If no value set, implies infinity.</p> <p>allowedValues: 0, 1, 2, 4, 5, 8, 10, 15, 20, 30, 40, 50, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 500, 750, 1000, 1250, 1500, 1750, 2000, 2250, 2500, 2750, 3000</p> | <p>Type: Integer</p> <p>multiplicity: 0..1</p> <p>isOrdered: N/A</p> <p>isUnique: N/A</p> <p>defaultValue: -</p> <p>isNullable: False</p> | +| rlc-mode | <p>RLC mode for this PDCP Configuration. See TS 38.463 [13].</p> <p>allowedValues: RLC-TM, RLC-AM, RLC-UM-BIDIRECTIONAL, RLC-UM-BIDIRECTIONAL-UL, RLC-UM-UNIDIRECTIONAL-DL</p> | <p>Type: ENUM rlcModeType</p> <p>multiplicity: 1</p> <p>isOrdered: N/A</p> <p>isUnique: N/A</p> <p>defaultValue: -</p> <p>isNullable: False</p> | +| header-compression-enabled | <p>Specifies whether ROHC should be enabled for this PDCP Configuration. See TS 38.331 [12].</p> | <p>Type: Boolean</p> <p>multiplicity: 1</p> <p>isOrdered: N/A</p> <p>isUnique: N/A</p> <p>defaultValue: -</p> <p>isNullable: False</p> | +| ul-data-split-threshold | <p>Uplink Data Split Threshold in bytes for this PDCP Configuration. See TS 38.331 [12].</p> <p>If no value set, implies infinity.</p> <p>allowedValues: 0, 100, 200, 400, 800, 1600, 3200, 6400, 12800, 25600, 51200, 102400, 204800, 409600, 819200, 1228800, 1638400, 2457600, 3276800, 4096000, 4915200, 5734400, 6553600</p> | <p>Type: Integer</p> <p>multiplicity: 0..1</p> <p>isOrdered: N/A</p> <p>isUnique: N/A</p> <p>defaultValue: -</p> <p>isNullable: False</p> | + +## 12 Trace Management Services + +Trace Management Service for both O-CU-CP and O-CU-UP are aligned with O1 Interface Specification [3], clause 6.4. The O-CU-CP and O-CU-UP can be Trance MnS Provider independently + +### 12.1 Call Trace + +Call Trace for both O-CU-CP and O-CU-UP are aligned with O1 Interface Specification [3], clause 6.4.1. + +### 12.2 Minimization of Drive Testing (MDT) + +Minimization of Drive Testing for both O-CU-CP and O-CU-UP are aligned with O1 Interface Specification [3], clause 6.4.2. + +### 12.3 Radio Link Failure (RLF) + +Radio Link Failure for both O-CU-CP and O-CU-UP are aligned with O1 Interface Specification [3], clause 6.4.3. + +## 12.4 RRC Connection Establishment Failure (RCEF) + +RRC Connection Establishment Failure for both O-CU-CP and O-CU-UP are aligned with O1 Interface Specification [3], clause 6.4.4. + +## 12.5 Trace Control + +Trace Control for both O-CU-CP and O-CU-UP are aligned with O1 Interface Specification [3], clause 6.4.5. + +## 12.6 Streaming Trace + +Streaming Trace for both O-CU-CP and O-CU-UP are aligned with O1 Interface Specification [3], clause 6.4.6. + +# Annex A (informative) : Counter definition + +### A.1 NR PDCP performance counters (Type A): + +#### A.1.1 Distribution of UE per UL received data volume + +##### A.1.1.1 Performance Counter Table + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPA.DistUeUlRxData | +| Description | This counter provides the distribution of the UE per received uplink data volume. When more than one RLCs are configured, the data volume refers to the all volume regardless through which RLC the data is transferred. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | If O-CU connects 5GC, measurement subcounter is the number of the QoS flow of which <i>x</i> is mapped to bin of subcounter. <i>binX</i> .<br>If O-CU connects EPC, measurement subcounter is the number of the bearer of which <i>x</i> is mapped to the bin of subcounter. <i>binX</i> .<br>The number, <i>x</i> is acquired and calculated at the end of measurement period (100ms).<br><i>x</i> is incremented by the volume of the UL PDCP PDU volume whenever the UL PDCP PDU is received from lower layer when the UL PDCP PDU is mapped to group of subcounter. <i>QoS</i> , subcounter. <i>SNSSAI</i> , or subcounter. <i>Cucountgroup</i> . | +| Measurement Result | Integer (U16) | +| Measurement Type | OR.PDCPA.DistUeUlRxData. <i>binX</i> , or optionally OR.PDCPA.DistUeUlRxData. <i>binX.QoS</i> , where <i>QoS</i> identifies the target quality of service class, and OR.PDCPA.DistUeUlRxData. <i>binX.SNSSAI</i> , where <i>SNSSAI</i> identifies the S-NSSAI, and OR.PDCPA.PDCPA.DistUeUlRxData. <i>binX.Cucountgroup</i> , where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC, and where <i>binX</i> is the bin of the throughput, x:<br>bin 1: 0 Byte < x < 1 kByte<br>bin 2: 1 kByte ≤ x < 2 kByte<br>bin 3: 2 kByte ≤ x < 5 kByte<br>bin 4: 5 kByte ≤ x < 10 kByte<br>bin 5: 10 kByte ≤ x < 20 kByte<br>bin 6: 20 kByte ≤ x < 50 kByte<br>bin 7: 50 kByte ≤ x < 100 kByte<br>bin 8: 100 kByte ≤ x < 200 kByte<br>bin 9: 200 kByte ≤ x < 500 kByte<br>bin 10: 500 kByte ≤ x < 1 MByte<br>bin 11: 1 MByte ≤ x < 1.5 MByte<br>bin 12: 1.5 MByte ≤ x < 2 MByte<br>bin 13: 2 MByte ≤ x < 2.5 MByte<br>bin 14: 2.5 MByte ≤ x < 3 MByte<br>bin 15: 3 MByte ≤ x < 3.5 MByte<br>bin 16: 3.5 MByte ≤ x < 4 MByte<br>bin 17: 4 MByte ≤ x < 4.5 MByte<br>bin 18: 4.5 MByte ≤ x < 5 MByte<br>bin 19: 5 MByte ≤ x < 10 MByte<br>bin 20: 10 MByte ≤ x | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator’s Traffic Engineering Community | + +## A.1.2 Distribution of DL UE throughput in O-CU + +### A.1.2.1 Performance Counter Table + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPA.DistDlUeThroughput | +| Description | This counter provides the distribution of the UE throughput in downlink. When more than one RLCs are configured, the data volume refers to the all volume regardless through which RLC the data is transferred. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>If O-CU connects 5GC, measurement subcounter is the number of the QoS flow of which throughput, x/y is mapped to bin of subcounter.<i>binX</i>. If O-CU connects EPC, measurement subcounter is the number of the bearer of which throughput, x/y is mapped to bin of subcounter.<i>binX</i>. The number, x/y is acquired and calculated at the end of measurement period.</p> <p>x is incremented by the volume of the DL PDCP PDU volume which is acknowledged by the DDDS whenever DDDS is received when PDCP PDU is mapped to group of subcounter.<i>QoS</i>, subcounter.<i>SNSSAI</i>, or subcounter.<i>Cucountgroup</i>.</p> <p>y is the smaller value in the followings:</p> <ul style="list-style-type: none"> <li><math>y = \Sigma(y1 - y2)</math>:<br/>where y1 is the point in time after y2 when data up until the second last piece of data in the transmitted data burst which emptied the PDCP SDU available for transmission for the group of subcounter.<i>Cucountgroup</i> was successfully transmitted, as acknowledged by the UE, and where y2 is the point in time when the first transmission begins after a PDCP SDU becomes available for transmission, where previously no PDCP SDUs were available for transmission for the particular subcounter.<i>QoS</i>, subcounter.<i>SNSSAI</i>, or subcounter.<i>Cucountgroup</i>.</li> <li>The measurement report period is 60000 ms.</li> </ul> | +| Measurement Result | Integer (U16) | +| Measurement Type | <p>OR.PDCPA.DistDlUeThroughput.<i>binX</i>, or optionally OR.PDCPA.DistDlUeThroughput.<i>binX.QoS</i>, where <i>QoS</i> identifies the target quality of service class, and</p> <p>OR.PDCPA.DistDlUeThroughput.<i>binX.SNSSAI</i>, where <i>SNSSAI</i> identifies the S-NSSAI, and</p> <p>OR.PDCPA.DistDlUeThroughput.<i>binX.Cucountgroup</i>, where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC, and where <i>binX</i> is the bin of the throughput, x/y:<br/> bin 1: <math>0 \text{ Mbps} \leq x/y < 1 \text{ Mbps}</math><br/> bin 2: <math>1 \text{ Mbps} \leq x/y < 2 \text{ Mbps}</math><br/> bin 3: <math>2 \text{ Mbps} \leq x/y < 5 \text{ Mbps}</math><br/> bin 4: <math>5 \text{ Mbps} \leq x/y < 10 \text{ Mbps}</math><br/> bin 5: <math>10 \text{ Mbps} \leq x/y < 20 \text{ Mbps}</math><br/> bin 6: <math>20 \text{ Mbps} \leq x/y < 50 \text{ Mbps}</math></p> | + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | bin 7: $50 \text{ Mbps} \leq x/y < 100 \text{ Mbps}$<br>bin 8: $100 \text{ Mbps} \leq x/y < 200 \text{ Mbps}$<br>bin 9: $200 \text{ Mbps} \leq x/y < 500 \text{ Mbps}$<br>bin 10: $500 \text{ Mbps} \leq x/y < 1 \text{ Gbps}$<br>bin 11: $1 \text{ Gbps} \leq x/y < 1.5 \text{ Gbps}$<br>bin 12: $1.5 \text{ Gbps} \leq x/y < 2 \text{ Gbps}$<br>bin 13: $2 \text{ Gbps} \leq x/y < 2.5 \text{ Gbps}$<br>bin 14: $2.5 \text{ Gbps} \leq x/y < 3 \text{ Gbps}$<br>bin 15: $3 \text{ Gbps} \leq x/y < 3.5 \text{ Gbps}$<br>bin 16: $3.5 \text{ Gbps} \leq x/y < 4 \text{ Gbps}$<br>bin 17: $4 \text{ Gbps} \leq x/y < 4.5 \text{ Gbps}$<br>bin 18: $4.5 \text{ Gbps} \leq x/y < 5 \text{ Gbps}$<br>bin 19: $5 \text{ Gbps} \leq x/y < 10 \text{ Gbps}$<br>bin 20: $10 \text{ Gbps} \leq x/y$ | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.3 Total discarded UL PDCP SDU volume + +### A.1.3.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPA.TotalDiscardedUIPdcPsdVol | +| Description | This counter provides the UL PDCP SDU volume discarded at PDCP due to any cause. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The measurement counter is incremented by the volume of the UL PDCP SDU whenever the UL PDCP SDU volume is discarded when the UL PDCP SDU is mapped to group of subcounter. <i>Cucountgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.PDCPA.TotalDiscardedUIPdcPsdVol, or optionally OR.PDCPA.TotalDiscardedUIPdcPsdVol. <i>QoS</i> , where <i>QoS</i> identifies the target quality of service class, and OR.PDCPA.TotalDiscardedUIPdcPsdVol. <i>SNSSAI</i> , where <i>SNSSAI</i> identifies the S-NSSAI, and OR.PDCPA.TotalDiscardedUIPdcPsdVol. <i>Cucountgroup</i> , where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.4 UL PDCP SDU volume discarded due to bearer release + +### A.1.4.1 Performance Counter Table + +| | | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPA.UIPdcPsdVolDiscardBearerRel | +| Description | This counter provides the UL PDCP SDU volume discarded at PDCP due to bearer release. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | The measurement counter is incremented by the volume of the UL PDCP SDU whenever the UL PDCP SDU volume is discarded due to bearer release when the UL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.PDCPA.UlPdcPsdUVolDiscardBearerRel, or optionally<br>OR.PDCPA.UlPdcPsdUVolDiscardBearerRel.QoS, where QoS identifies the target quality of service class, and<br>OR.PDCPA.UlPdcPsdUVolDiscardBearerRel.SNSSAI, where SNSSAI identifies the S-NSSAI, and<br>OR.PDCPA.UlPdcPsdUVolDiscardBearerRel.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.1.5 Total discarded DL PDCP SDU volume discarded + +3 + +### A.1.5.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPA.TotalDiscardedDlPdcPsdUVol | +| Description | This counter provides the DL PDCP SDU volume discarded at PDCP due to any causes. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The measurement counter is incremented by the volume of the DL PDCP SDU whenever the DL PDCP SDU volume is discarded when the DL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.PDCPA.TotalDiscardedDlPdcPsdUVol, or optionally<br>OR.PDCPA.TotalDiscardedDlPdcPsdUVol.QoS, where QoS identifies the target quality of service class, and<br>OR.PDCPA.TotalDiscardedDlPdcPsdUVol.SNSSAI, where SNSSAI identifies the S-NSSAI, and<br>OR.PDCPA.TotalDiscardedDlPdcPsdUVol.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +5 + +## A.1.6 DL PDCP SDU volume discarded due to bearer release + +6 + +### A.1.6.1 Performance Counter Table + +| | | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPA.DlPdcPsdUVolDiscardLessBearerRel | +| Description | This counter provides the DL PDCP SDU volume discarded at PDCP due to bearer release. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | The measurement counter is incremented by the volume of the DL PDCP SDU whenever the DL PDCP SDU volume is discarded due to bearer release when the DL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.PDCPA.DIPdcpSduVolDiscardLessBearerRel, or optionally OR.PDCPA.DIPdcpSduVolDiscardLessBearerRel.QoS, where QoS identifies the target quality of service class, and OR.PDCPA.DIPdcpSduVolDiscardLessBearerRel.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.PDCPA.DIPdcpSduVolDiscardLessBearerRel.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.1.7 DL PDCP SDU volume discarded due to out of memory + +3 + +### A.1.7.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPA.DIPdcpSduVolDiscardOutOfMemory | +| Description | This counter provides the DL PDCP SDU volume discarded at PDCP due to out of memory. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The measurement counter is incremented by the volume of the DL PDCP SDU whenever the DL PDCP SDU volume is discarded due to out of memory when the DL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.PDCPA.DIPdcpSduVolDiscardOthercauses, or optionally OR.PDCPA.DIPdcpSduVolDiscardOthercauses.QoS, where QoS identifies the target quality of service class, and OR.PDCPA.DIPdcpSduVolDiscardOthercauses.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.PDCPA.DIPdcpSduVolDiscardOthercauses.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +5 + +## A.1.8 PDCP transmission stop + +6 + +### A.1.8.1 Performance Counter Table + +| | | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPA.PdcpTxStop | +| Description | This counter the number of the detection of PDCP transmission stop. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | The measurement counter is incremented by 1 whenever PDCP transmission stop is occurred when the PDCP SDU is mapped to group of subcounter. It is incremented by 1 at most in each CU count group for one radio bearer until the transmission stop is resolved. | +| Measurement Result | Integer (U16) | +| Measurement Type | OR.PdcpxTxStop, or optionally OR.PdcpxTxStop.QoS, where QoS identifies the target quality of service class, and OR.PdcpxTxStop.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.PdcpxTxStop.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## A.1.9 UL F1-U packet loss rate + +### A.1.9.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | DRB.F1UpacketLossRateUl | +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.2<br><br><u>O-RAN addition:</u><br>The split into subcounters per S-NSSAI is recommended when the Slicing feature is supported.<br>The split into subcounters per QoS is recommended where QoS identifies the target quality of service class. | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.2 | +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.2<br><br><u>O-RAN addition:</u><br>The numbers are accumulated in the reference measurement period T (1000ms). | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.2 | +| Measurement Type | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.2 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.2 | +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.2 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.2 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.2 | + +4 + +## A.1.10 UL PDCP SDU Loss Rate + +### A.1.10.1 Performance Counter Table + +| | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | DRB.PacketLossRateUl | +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.1<br><br><u>O-RAN addition:</u><br>The split into subcounters per S-NSSAI is recommended when the Slicing feature is supported.<br>The split into subcounters per QoS is recommended where QoS identifies the target quality of service class | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.1 | + +6 + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.1<br><br><u>O-RAN addition:</u><br>The numbers are accumulated in the reference measurement period T (1000ms). | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.1 | +| Measurement Type | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.1 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.1 | +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.1 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.1 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.1 | + +1 + +## 2 A.1.11 DL PDCP SDU Loss Rate + +### 3 A.1.11.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | DRB.PacketLossRateDL | +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.3.2.1<br><br><u>O-RAN addition:</u><br>The split into subcounters per S-NSSAI is recommended when the Slicing feature is supported.<br>The split into subcounters per QoS is recommended where QoS identifies the target quality of service class | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.3.2.1 | +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.3.2.1<br><br><u>O-RAN addition:</u><br>The numbers are accumulated in the reference measurement period T (1000ms). | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.3.2.1 | +| Measurement Type | Refer to 3GPP TS 28.552 [8] clause 5.1.3.2.1 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.3.2.1 | +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.3.2.1 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.3.2.1 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.3.2.1 | + +4 + +## 5 A.1.12 DL F1-U packet loss rate + +### 6 A.1.12.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | DRB.F1UpacketLossRateDL | +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.3<br><br><u>O-RAN addition:</u><br>The split into subcounters per S-NSSAI is recommended when the Slicing feature is supported.<br>The split into subcounters per QoS is recommended where QoS identifies the target quality of service class. | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.3 | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.3<br><br><u>O-RAN addition:</u><br>The numbers are accumulated in the reference measurement period T (1000ms). | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.3 | +| Measurement Type | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.3 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.3 | +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.3 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.3 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.3.1.3 | + +## A.2 NR PDCP performance counters (Type B): + +### A.2.1 UL PDCP SDU Data Volume + +#### A.2.1.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.UIPdcPsdDataVol | +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.2<br><br><u>O-RAN addition:</u><br>The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of CuCountgroup IOC may be used to define subcounter configurations. | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.2 | +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.2<br><br><u>O-RAN addition:</u><br>The subcounter per QoS level should be regarded as subcounter QoS, SNSSAI or CuCountgroup.<br>Note: excludes UL PDCP SDU received as data forwarding. | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.2 | +| Measurement Type | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.2<br><br><u>O-RAN addition:</u><br>OR.PDCPB.UIPdcPsdDataVol, or optionally<br>OR.PDCPB.UIPdcPsdDataVol. <i>QoS</i> , where <i>QoS</i> identifies the target quality of service class, and OR.PDCPB.UIPdcPsdDataVol. <i>SNSSAI</i> , where <i>SNSSAI</i> identifies the S-NSSAI, and<br>OR.PDCPB.UIPdcPsdDataVol. <i>CuCountgroup</i> , where <i>CuCountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.2 | +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.2 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.2 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.2 | + +### A.2.2 UL PDCP SDU Data Volume on X2 Interface + +#### A.2.2.1 Performance Counter Table + +| | | +|------------------|----------------------------| +| Measurement Name | OR.PDCPB.UIPdcPsdDataVolX2 | +|------------------|----------------------------| + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4<br><br><u>O-RAN addition:</u><br>The measurement is for X2 interface.<br>The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4<br><br><u>O-RAN addition:</u><br>The measurement is for X2 interface.<br>The subcounter per QoS level should be regarded as subcounter QoS, SNSSAI or Cucountgroup.<br>Note: excludes UL PDCP SDU received as data forwarding. | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | +| Measurement Type | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4<br><br><u>O-RAN addition:</u><br>OR.PDCPB.UIPdcPsdDataVolX2, or optionally<br>OR.PDCPB.UIPdcPsdDataVolX2.QoS, where QoS identifies the target quality of service class, and OR.PDCPB.UIPdcPsdDataVolX2.SNSSAI, where SNSSAI identifies the S-NSSAI, and<br>OR.PDCPB.UIPdcPsdDataVolX2.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | + +1 + +2 + +## A.2.3 UL PDCP SDU Data Volume on Xn Interface + +3 + +### A.2.3.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.UIPdcPsdDataVolXn | +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4<br><br><u>O-RAN addition:</u><br>The measurement is for Xn interface.<br>The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4<br><br><u>O-RAN addition:</u><br>The measurement is for Xn interface.<br>The subcounter per QoS level should be regarded as subcounter QoS, SNSSAI or Cucountgroup.<br>Note: excludes UL PDCP SDU received as data forwarding. | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | +| Measurement Type | OR.PDCPB.UIPdcPsdDataVolXn, or optionally<br>OR.PDCPB.UIPdcPsdDataVolXn.QoS, where QoS identifies the target quality of service class, and OR.PDCPB.UIPdcPsdDataVolXn.SNSSAI, where SNSSAI identifies the S-NSSAI, and<br>OR.PDCPB.UIPdcPsdDataVolXn.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | + +| | | +|----------------------|------------------------------------------------| +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.4 | + +## A.2.4 DL PDCP SDU Data Volume + +### A.2.4.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.DlPdcPsdDataVol | +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.1<br><br><u>O-RAN addition:</u><br>The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.1 | +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.1<br><br><u>O-RAN addition:</u><br>The subcounter per QoS level should be regarded as subcounter QoS, SNSSAI or Cucountgroup.<br>Note: excludes DL PDCP SDU transmitted as data forwarding. | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.1 | +| Measurement Type | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.1<br><br><u>O-RAN addition:</u><br>OR.PDCPB.DlPdcPsdDataVol, or optionally<br>OR.PDCPB.DlPdcPsdDataVol.QoS, where QoS identifies the target quality of service class, and OR.PDCPB.DlPdcPsdDataVol.SNSSAI, where SNSSAI identifies the S-NSSAI, and<br>OR.PDCPB.DlPdcPsdDataVol.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.1 | +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.1 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.1 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.1 | + +## A.2.5 DL PDCP SDU Data Volume on X2 Interface + +### A.2.5.1 Performance Counter Table + +| | | +|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.DlPdcPsdDataVolX2 | +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3<br><br><u>O-RAN addition:</u><br>The measurement is for X2 interface.<br>The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in NR option 3) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3<br><br><u>O-RAN addition:</u><br>The measurement is for X2 interface.<br>The subcounter per QoS level should be regarded as subcounter QoS, SNSSAI or Cucountgroup. | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Note: excludes DL PDCP SDU transmitted as data forwarding. | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | +| Measurement Type | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3<br><br><u>O-RAN addition:</u><br>OR.PDCPB.DlPdcPsdUDataVolX2, or optionally<br>OR.PDCPB.DlPdcPsdUDataVolX2.QoS, where QoS identifies the target quality of service class, and OR.PDCPB.DlPdcPsdUDataVolX2.SNSSAI, where SNSSAI identifies the S-NSSAI, and<br>OR.PDCPB.DlPdcPsdUDataVolX2.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | + +## A.2.6 DL PDCP SDU Data Volume on Xn Interface + +### A.2.6.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.DlPdcPsdUDataVolXnCell | +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3<br><br><u>O-RAN addition:</u><br>The measurement is for Xn interface.<br>The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in NR option 3) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3<br><br><u>O-RAN addition:</u><br>The measurement is for Xn interface.<br>The subcounter per QoS level should be regarded as subcounter QoS, SNSSAI or Cucountgroup.<br>Note: excludes DL PDCP SDU transmitted as data forwarding. | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | +| Measurement Type | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3<br><br><u>O-RAN addition:</u><br>OR.PDCPB.DlPdcPsdUDataVolXn, or optionally<br>OR.PDCPB.DlPdcPsdUDataVolXn.QoS, where QoS identifies the target quality of service class, and OR.PDCPB.DlPdcPsdUDataVolXn.SNSSAI, where SNSSAI identifies the S-NSSAI, and<br>OR.PDCPB.DlPdcPsdUDataVolXn.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.3.6.2.3 | + +## A.2.7 UL PDCP SDU Data Volume per cell + +### A.2.7.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.UIPdcPsdDataVolCell | +| Description | This counter provides the UL PDCP SDU volume received via X2, Xn or F1. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in NR option 3) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of UL PDCP SDU whenever the UL PDCP PDU is received via X2-U, Xn-U or F1-U UL GTP-u tunnel when the UL PDCP SDU is mapped to group of subcounter.<br>Note: excludes UL PDCP SDU received as data forwarding. | +| Measurement Result | Mbit (U32) | +| Measurement Type | OR.PDCPB.UIPdcPsdDataVolCell, or optionally OR.PDCPB.UIPdcPsdDataVolCell.QoS, where QoS identifies the target quality of service class, and OR.PDCPB.UIPdcPsdDataVolCell.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.PDCPB.UIPdcPsdDataVolCell.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.8 UL PDCP SDU Data Volume on X2 Interface per cell + +### A.2.8.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.UIPdcPsdDataVolX2Cell | +| Description | This counter provides the UL PDCP SDU volume received via X2. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in NR option 3) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of UL PDCP SDU whenever the UL PDCP PDU is received via X2-U UL GTP-u tunnel when the UL PDCP SDU is mapped to group of subcounter.<br>Note: excludes UL PDCP SDU received as data forwarding. | +| Measurement Result | Mbit (U32) | +| Measurement Type | OR.PDCPB.UIPdcPsdDataVolX2Cell, or optionally OR.PDCPB.UIPdcPsdDataVolX2Cell.QoS, where QoS identifies the target quality of service class, and OR.PDCPB.UIPdcPsdDataVolX2Cell.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.PDCPB.UIPdcPsdDataVolX2Cell.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.9 UL PDCP SDU Data Volume on Xn Interface per cell + +### A.2.9.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.UIPdcPsdUDataVolXnCell | +| Description | This counter provides the UL PDCP SDU volume received via Xn. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in NR option 3) or per S-NSSAI. An instance of CuCountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of UL PDCP SDU whenever the UL PDCP PDU is received via Xn-U UL GTP-u tunnel when the UL PDCP SDU is mapped to group of subcounter.<br>Note: excludes UL PDCP SDU received as data forwarding. | +| Measurement Result | Mbit (U32) | +| Measurement Type | OR.PDCPB.UIPdcPsdUDataVolXnCell, or optionally<br>OR.PDCPB.UIPdcPsdUDataVolXnCell.QoS, where QoS identifies the target quality of service class, and<br>OR.PDCPB.UIPdcPsdUDataVolXnCell.SNSSAI, where SNSSAI identifies the S-NSSAI, and<br>OR.PDCPB.UIPdcPsdUDataVolXnCell.CuCountgroup, where CuCountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.10 DL PDCP SDU Data Volume per cell + +### A.2.10.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.DIPdcPsdUDataVolCell | +| Description | This counter provides the DL PDCP SDU volume transmitted via X2, Xn or F1. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in NR option 3) or per S-NSSAI. An instance of CuCountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of DL PDCP SDU whenever the DL PDCP PDU is transmitted via X2-U, Xn-U or F1-U DL GTP-u tunnel when the DL PDCP SDU is mapped to group of subcounter.<br>Note: excludes DL PDCP SDU transmitted as data forwarding. | +| Measurement Result | Mbit (U32) | +| Measurement Type | OR.PDCPB.DIPdcPsdUDataVolCell, or optionally<br>OR.PDCPB.DIPdcPsdUDataVolCell.QoS, where QoS identifies the target quality of service class, and<br>OR.PDCPB.DIPdcPsdUDataVolCell.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.PDCPB.DIPdcPsdUDataVolCell.CuCountgroup, where CuCountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.11 DL PDCP SDU Data Volume on X2 Interface per cell + +### A.2.11.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.DlPdcPsdUDataVolX2Cell | +| Description | This counter provides the DL PDCP SDU volume transmitted via X2. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in NR option 3) or per S-NSSAI. An instance of CuCountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of DL PDCP SDU whenever the DL PDCP PDU is transmitted via X2-U DL GTP-u tunnel when the DL PDCP SDU is mapped to group of subcounter. Note: excludes DL PDCP SDU transmitted as data forwarding. | +| Measurement Result | Mbit (U32) | +| Measurement Type | OR.PDCPB.DlPdcPsdUDataVolX2Cell, or optionally OR.PDCPB.DlPdcPsdUDataVolX2Cell.QoS, where QoS identifies the target quality of service class, and OR.PDCPB.DlPdcPsdUDataVolX2Cell.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.PDCPB.DlPdcPsdUDataVolX2Cell.CuCountgroup, where CuCountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.12 DL PDCP SDU Data Volume on Xn Interface per cell + +### A.2.12.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDCPB.DlPdcPsdUDataVolXnCell | +| Description | This counter provides the DL PDCP SDU volume transmitted via Xn. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in NR option 3) or per S-NSSAI. An instance of CuCountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of DL PDCP SDU whenever the DL PDCP PDU is transmitted via Xn-U DL GTP-u tunnel when the DL PDCP SDU is mapped to group of subcounter. Note: excludes DL PDCP SDU transmitted as data forwarding. | +| Measurement Result | Mbit (U32) | +| Measurement Type | OR.PDCPB.DlPdcPsdUDataVolXnCell, or optionally OR.PDCPB.DlPdcPsdUDataVolXnCell.QoS, where QoS identifies the target quality of service class, and OR.PDCPB.DlPdcPsdUDataVolXnCell.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.PDCPB.DlPdcPsdUDataVolXnCell.CuCountgroup, where CuCountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.3 NR S1-U Interface Performance Counters + +### A.3.1 UL PDCP SDU volume transmitted via S1-U UL GTP-U tunnel + +#### A.3.1.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.S1.UIPdcPsdUVolTxS1UU1 | +| Description | This counter provides the UL PDCP SDU volume transmitted via S1-U UL GTP-U tunnel The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of UL PDCP SDU whenever the UL PDCP SDU is transmitted via S1-U UL GTP-u tunnel when the UL PDCP SDU is group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.S1.UIPdcPsdUVolTxS1UU1, or optionally OR.S1.UIPdcPsdUVolTxS1UU1.QoS, where QoS identifies the target quality of service class, and OR.S1.UIPdcPsdUVolTxS1UU1.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.S1.UIPdcPsdUVolTxS1UU1.Cucountgroup, where Cucountgroup identifies ann instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.3.2 DL PDCP SDU volume received via S1-U DL GTP-U tunnel + +#### A.3.2.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.S1.DIPdcPsdUVolRxS1UD1 | +| Description | This counter provides the DL PDCP SDU volume received via S1-U DL GTP-U tunnel The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of DL PDCP SDU whenever the DL PDCP SDU is received via S1-U DL GTP-u tunnel when the DL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.S1.DIPdcPsdUVolRxS1UD1, or optionally OR.S1.DIPdcPsdUVolRxS1UD1.QoS, where QoS identifies the target quality of service class, and OR.S1.DIPdcPsdUVolRxS1UD1.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.S1.DIPdcPsdUVolRxS1UD1.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.3.3 UL PDCP SDUs transmitted via S1-U UL GTP-U tunnel + +#### A.3.3.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.S1.UIPdcPduTxS1UUI | +| Description | This counter provides the number of the UL PDCP SDUs transmitted via S1-U UL GTP-U tunnel.<br>The counter is split into subcounters per GTP Path.<br>The counter is split into subcounter of subcounter per CuCountGroup. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the UL PDCP SDU is transmitted via S1 U UL GTP-u tunnel.<br>GTP Path subcounter is maintained, the number of measurements is accumulated per the number or supported GTP Path.<br>CuCountGroup subcounter of subcounter is maintained, the number of measurements is accumulated per the number of supported CucountGroup. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.S1.UIPdcPPduTxS1UUI. <i>GTPPath.Cugroup</i> where <i>GTPPath</i> is GTP Path.<br><i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.3.4 DL PDCP SDUs transmitted via S1-U DL GTP-U tunnel + +#### A.3.4.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.S1.DIPdcPduTxS1UDl | +| Description | This counter provides the number of the DL PDCP SDUs transmitted via S1-U DL GTP-U tunnel.<br>The counter is split into subcounters per GTP Path.<br>The counter is split into subcounter of subcounter per CuCountGroup. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the DL PDCP SDU is transmitted via S1 U DL GTP-u tunnel.<br>GTP Path subcounter is maintained, the number of measurements is accumulated per the number or supported GTP Path.<br>CuCountGroup subcounter of subcounter is maintained, the number of measurements is accumulated per the number of supported CucountGroup. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.S1.DIPdcPPduTxS1UDl. <i>GTPPath.Cugroup</i> where <i>GTPPath</i> is GTP Path.<br><i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.4 NR NG-U Interface Performance Counters + +### A.4.1 UL PDCP SDU volume transmitted via NG-U UL GTP-U tunnel + +#### A.4.1.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NG.UIPdcPsdUVolTxNGUUI | +| Description | This counter provides the UL PDCP SDU volume transmitted via NG-U UL GTP-U tunnel. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of UL PDCP SDU whenever the UL PDCP SDU is transmitted via NG-U UL GTP-u tunnel when the UL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.NG.UIPdcPsdUVolTxNGUUI, or optionally OR.NG.UIPdcPsdUVolTxNGUUI.QoS, where QoS identifies the target quality of service class, and OR.NG.UIPdcPsdUVolTxNGUUI.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.NG.UIPdcPsdUVolTxNGUUI.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.4.2 DL PDCP SDU volume received via NG-U DL GTP-U tunnel + +#### A.4.2.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NG.DIPdcPsdUVolRxNGUDI | +| Description | This counter provides the DL PDCP SDU volume received via NG-U DL GTP-U tunnel. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of DL PDCP SDU whenever the DL PDCP SDU is received via NG-U DL GTP-u tunnel when the DL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.NG.DIPdcPsdUVolRxNGUDI, or optionally OR.NG.DIPdcPsdUVolRxNGUDI.QoS, where QoS identifies the target quality of service class, and OR.NG.DIPdcPsdUVolRxNGUDI.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.NG.DIPdcPsdUVolRxNGUDI.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.5 NR X2-U Interface performance counters (O-CU) + +### A.5.1 UL PDCP SDU volume received via X2-U UL GTP-U tunnel (X2-U UL data forwarding) + +#### A.5.1.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.X2.UIPdcpsduVolRxX2UUIDataForward | +| Description | This counter provides the UL PDCP SDU volume received via X2-U UL GTP-U tunnel for data forwarding. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of CuCountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of UL PDCP SDU whenever the UL PDCP PDU is received via X2-U UL GTP-u tunnel for data forwarding when the UL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.X2.UIPdcpsduVolRxX2UUIDataForward, or optionally OR.X2.UIPdcpsduVolRxX2UUIDataForward.QoS, where QoS identifies the target quality of service class, and OR.X2.UIPdcpsduVolRxX2UUIDataForward.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.X2.UIPdcpsduVolRxX2UUIDataForward.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.5.2 DL PDCP SDU volume received via X2-U DL GTP-U tunnel (X2-U DL data forwarding) + +#### A.5.2.1 Performance Counter Table + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.X2.DIPdcpsduVolTxX2UDIDataForward | +| Description | This counter provides the DL PDCP SDU volume received via X2-U DL GTP-U tunnel for data forwarding. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of CuCountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of DL PDCP SDU whenever the DL PDCP PDU is transmitted via X2-U DL GTP-u tunnel for data forwarding when the DL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.X2.DIPdcpsduVolRxX2UDIDataForward, or optionally OR.X2.DIPdcpsduVolRxX2UDIDataForward.QoS, where QoS identifies the target quality of service class, and OR.X2.DIPdcpsduVolRxX2UDIDataForward.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.X2.DIPdcpsduVolRxX2UDIDataForward.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.6 NR Xn-U Interface performance counters (O-CU) + +### A.6.1 UL PDCP SDU volume received via Xn-U UL GTP-U tunnel (Xn-U UL data forwarding) + +#### A.6.1.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.Xn.UIPdcPsdUVolRxXnUUIDataForward | +| Description | This counter provides the UL PDCP SDU volume received via Xn-U UL GTP-U tunnel for data forwarding. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of CuCountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of UL PDCP SDU whenever the UL PDCP PDU is received via Xn-U UL GTP-u tunnel for data forwarding when the UL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.Xn.UIPdcPsdUVolRxXnUUIDataForward, or optionally OR.Xn.UIPdcPsdUVolRxXnUUIDataForward.QoS, where QoS identifies the target quality of service class, and OR.Xn.UIPdcPsdUVolRxXnUUIDataForward.SNSSAI, where SNSSAI identifies the S-NSSAI, and OR.Xn.UIPdcPsdUVolRxXnUUIDataForward.Cucountgroup, where Cucountgroup identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.6.2 DL PDCP SDU volume received via Xn-U DL GTP-U tunnel (Xn-U DL data forwarding) + +#### A.6.2.1 Performance Counter Table + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.Xn.DIPdcPsdUVolTxXnUDIDataForward | +| Description | This counter provides the DL PDCP SDU volume received via Xn-U DL GTP-U tunnel for data forwarding. The measurement is optionally split into subcounters per QoS level (mapped 5QI or QCI in EN-DC) or per S-NSSAI. An instance of Cucountgroup IOC may be used to define subcounter configurations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of DL PDCP SDU whenever the DL PDCP PDU is transmitted via Xn-U DL GTP-u tunnel for data forwarding when the DL PDCP SDU is mapped to group of subcounter. | +| Measurement Result | kilobyte (U32) | + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Type | OR.Xn.OR.Xn.DIPdcpSduVolTxXnUDIDataForward, or optionally OR.Xn.OR.Xn.DIPdcpSduVolTxXnUDIDataForward. <i>QoS</i> , where <i>QoS</i> identifies the target quality of service class, and OR.Xn.OR.Xn.DIPdcpSduVolTxXnUDIDataForward. <i>SNSSAI</i> , where <i>SNSSAI</i> identifies the S-NSSAI, and OR.Xn.OR.Xn.DIPdcpSduVolTxXnUDIDataForward. <i>Cucountgroup</i> , where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | GNBCUUPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7 NR X2-C Interface performance counters (O-CU) + +### A.7.1 Transmitted X2-C messages + +#### A.7.1.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.X2.TxX2CMesg | +| Description | This counter provides the number of the transmitted X2-C messages per signal type that is non UE-associated or UE-associated signaling TS 38.401 [11]. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever X2 C-plane message is transmitted when the signal type of the X2 C-plane message is group of <i>Signaltype</i> . | +| Measurement Result | Integer (32) | +| Measurement Type | OR.X2.TxX2CMesg. <i>Signaltype</i> where <i>Signaltype</i> is signal type:<br>0: non UE-associated<br>1: UE associated | +| Measurement Object Class | GNBCUCPFFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.7.2 Received X2-C messages + +#### A.7.2.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.X2.RxX2CMesg | +| Description | This counter provides the number of the received X2-C messages per signal type that is non UE-associated or UE-associated signaling TS 38.401 [11]. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever X2 C-plane message is received when the signal type of the X2 C-plane message is group of <i>Signaltype</i> . | +| Measurement Result | Integer (32) | +| Measurement Type | OR.X2.RxX2CMesg. <i>Signaltype</i> where <i>Signaltype</i> is signal type:<br>0: non UE-associated<br>1: UE associated | +| Measurement Object Class | GNBCUCPFFunction | +| Switching Technology | Packet Switched | + +| | | +|------------|--------------------------------------------------| +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.8 NR Xn-C Interface performance counters (O-CU) + +### A.8.1 Transmitted Xn-C messages + +#### A.8.1.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.Xn.TxXnCMesg | +| Description | This counter provides the number of the transmitted Xn-C messages per signal type that is non UE-associated or UE-associated signaling TS 38.401 [11]. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Xn C-plane message is transmitted when the signal type of Xn C-plane message is group of <i>Signaltype</i> . | +| Measurement Result | Integer (32) | +| Measurement Type | OR.Xn.TxXnCMesg. <i>Signaltype</i> where <i>Signaltype</i> is signal type:<br>0: non UE-associated<br>1: UE associated | +| Measurement Object Class | GNBCUCPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.8.2 Received Xn-C messages + +#### A.8.2.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.Xn.RxXnCMesg | +| Description | This counter provides the number of the received Xn-C messages per signal type that is non UE-associated or UE-associated signaling TS 38.401 [11]. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Xn C-plane message is received when the signal type of the Xn C-plane message is group of <i>Signaltype</i> . | +| Measurement Result | Integer (32) | +| Measurement Type | OR.Xn.RxXnCMesg. <i>Signaltype</i> where <i>Signaltype</i> is signal type:<br>0: non UE-associated<br>1: UE associated | +| Measurement Object Class | GNBCUCPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.9 NR F1-C Interface performance counters (O-CU-CP) + +### A.9.1 Transmitted F1-C messages + +#### A.9.1.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.TxF1CMesg | +| Description | This counter provides the number of the transmitted F1-C messages per signal type that is non UE-associated or UE-associated signaling TS 38.401 [11]. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever F1 C-plane message is transmitted when the signal type of the F1 C-plane message is group of <i>Signaltype</i> . | +| Measurement Result | Integer (32) | +| Measurement Type | OR.F1.TxF1CMesg. <i>Signaltype</i> where <i>Signaltype</i> is signal type:<br>0: non UE-associated<br>1: UE associated | +| Measurement Object Class | GNBCUCPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.9.2 Received F1-C messages + +#### A.9.2.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.RxF1CMesg | +| Description | This counter provides the number of the received F1-C messages per signal type that is non UE-associated or UE-associated signaling TS 38.401 [11]. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever F1 C-plane message is received when the signal type of the F1 C-plane message is group of <i>Signaltype</i> . | +| Measurement Result | Integer (32) | +| Measurement Type | OR.F1.RxF1CMesg. <i>Signaltype</i> where <i>Signaltype</i> is signal type:<br>0: non UE-associated<br>1: UE associated | +| Measurement Object Class | GNBCUCPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.10 Number of UE Contexts for EN-DC + +### A.10.1 Max SN terminated split bearer UE Contexts + +#### A.10.1.1 Performance Counter Table + +| | | +|------------------|---------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.MaxSnSplitBearer | +| Description | This counter provides the maximum number of UE Contexts that are configured SN terminated split bearer. | + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.</p> <p>x is the number of the UE Context that are configured as SN terminated split bearer.</p> <p>x is acquired as an instantaneous value at every 100ms.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (to SN terminated split bearer)</li> <li>- received X2-AP: SgNB Modification Confirm (Intra/Inter DU PSCell change using SRB1 (for target cell))</li> <li>- received RRC: RRC Reconfiguration Complete (Intra/Inter DU PSCell change using SRB3 (for target cell))</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (to SN terminated MCG bearer)</li> <li>- received X2-AP: SgNB Modification Confirm (Intra/Inter DU PSCell change using SRB1 (for source cell))</li> <li>- received F1-AP: UE Context Release Complete (Intra/Inter DU PSCell change using SRB3 (for source cell))</li> <li>- received X2-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UEENDC.MaxSnSplitBearer | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.10.2 Max SN terminated MCG bearer UE Contexts + +### A.10.2.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.MaxSnMcgBearer | +| Description | This counter provides the maximum number of UE Contexts that are configured SN terminated MCG bearer. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.</p> <p>x is the number of the UE Contexts that are configured as SN terminated MCG bearer.</p> <p>x is acquired as an instantaneous value at every 100ms.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (to SN terminated MCG bearer)</li> <li>- received X2-AP: SgNB Reconfiguration Confirm (to SN terminated MCG bearer)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (to SN terminated split bearer)</li> </ul> </li> </ul> | + +| | | +|--------------------------|--------------------------------------------------| +| | - received X2-AP: UE Context Release | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UEENDC.MaxSnMcgBearer | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.10.3 Average SN terminated split bearer UE Contexts + +### A.10.3.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.AveSnSplitBearer | +| Description | This counter provides the average number of UE Contexts that are configured SN terminated split bearer. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is x/y.</p> <p>x is incremented by the number of UE Contexts that are configured SN terminated split bearer. This counter obtains the number of the UE Contexts every 100ms.</p> <p>y is calculated as measurement period divided by 100ms.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (to SN terminated split bearer)</li> <li>- received X2-AP: SgNB Modification Confirm (Intra/Inter DU PSCell change using SRB1 (for target cell))</li> <li>- received RRC: RRC Reconfiguration Complete (Intra/Inter DU PSCell change using SRB3 (for target cell))</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (to SN terminated MCG bearer)</li> <li>- received X2-AP: SgNB Modification Confirm (Intra/Inter DU PSCell change using SRB1 (for source cell))</li> <li>- received F1-AP: UE Context Release Complete (Intra/Inter DU PSCell change using SRB3 (for source cell))</li> <li>- received X2-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UEENDC.AveSnSplitBearer | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.10.4 Average SN terminated MCG bearer UE Contexts + +### A.10.4.1 Performance Counter Table + +| | | +|------------------|------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.AveSnMcgBearer | +| Description | This counter provides the average number of UE Contexts that are configured SN terminated MCG bearer that are already setup. | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Collection Method | SI | +| Condition | <p>Measurement subcounter is x/y.</p> <p>x is incremented by the number of UE Contexts that are configured SN terminated MCG bearer. This counter obtains the number of the UE Contexts every 100ms.</p> <p>y is calculated as measurement period divided by 100ms.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (to SN terminated MCG bearer)</li> <li>- received X2-AP: SgNB Reconfiguration Confirm (to SN terminated MCG bearer)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (to SN terminated split bearer)</li> <li>- received X2-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UEENDC.AveSnMcgBearer | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.10.5 Total DL CA UE Contexts PSCell (100ms) + +### A.10.5.1 Performance Counter Table + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.TotalDlCaUePscell100ms | +| Description | This counter provides the total number of UE Contexts that are set of DL CA as PSCell in units of NR Cell. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.</p> <p>x is the number of the UE Contexts using this cell as PSCell per the number of CC configured for DL CA in unit of NR Cell group as subcounter. <i>Ccnum</i> by every 100ms.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell addition)</li> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell addition/change)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell release)</li> <li>- received RRC: RRC Reconfiguration Complete (SCell release/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell release/change)</li> <li>- received X2-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | integer(U32) | +| Measurement Type | OR.UEENDC.TotalDlCaUePscell100ms. <i>Ccnum</i> where <i>Ccnum</i> is the number of CC: | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | 0: #0CC (number of SCell excluding PSCell in the cell group)<br>1: #1CC (number of SCell excluding PSCell in the cell group)<br>...<br>7: #7CC (number of SCell excluding PSCell in the cell group) | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.10.6 Total DL CA UE Contexts PSCell (10s) + +3 + +### A.10.6.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.TotalDlCaUePscell10s | +| Description | This counter provides the total number of UE Contexts that are set of DL CA as PSCell in units of NR Cell. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.</p> <p>x is the number of the UE Contexts using this cell as PSCell per the number of CC configured for DL CA in unit of NR Cell group as subcounter: <i>Ccnum</i> by every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell addition)</li> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell addition/change)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell release)</li> <li>- received F1-AP: UE Context Release Complete (SCell release/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell release/change)</li> <li>- received X2-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | integer(U32) | +| Measurement Type | OR.UEENDC.TotalDlCaUePscell10s. <i>Ccnum</i> where <i>Ccnum</i> is the number of CC:<br>0: #0CC (number of SCell excluding PSCell in the cell group)<br>1: #1CC (number of SCell excluding PSCell in the cell group)<br>...<br>7: #7CC (number of SCell excluding PSCell in the cell group) | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## A.10.7 Total DL CA UE Contexts SCell (100ms) + +### A.10.7.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.TotalDlCaUeScell100ms | +| Description | This counter provides the total number of UE Contexts that are set of DL CA as SCell in units of NR Cell. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.<br/> x is the number of the UE Contexts using this cell as SCell per the number of CC configured for DL CA in unit of NR Cell group as subcounter. <i>Ccnum</i> by every 100ms.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell addition)</li> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell addition/change)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell release)</li> <li>- received F1-AP: UE Context Release Complete (SCell release/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell release/change)</li> <li>- received X2-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | integer(U32) | +| Measurement Type | OR.UEENDC.TotalDlCaUeScell100ms. <i>Ccnum</i> where <i>Ccnum</i> is the number of CC:<br>0: #1CC (number of SCell excluding PSCell in the cell group)<br>1: #2CC (number of SCell excluding PSCell in the cell group)<br>...<br>6: #7CC (number of SCell excluding PSCell in the cell group) | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.10.8 Total DL CA UE Contexts SCell (10s) + +### A.10.8.1 Performance Counter Table + +| | | +|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.TotalDlCaUeScell10s | +| Description | This counter provides the total number of UE Contexts that are set of DL CA as SCell in units of NR Cell. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.<br/> x is the number of the UE Contexts using this cell as SCell per the number of CC configured for DL CA in unit of NR Cell group as subcounter. <i>Ccnum</i> by every 10s.</p> | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell addition)</li> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell addition/change)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell release)</li> <li>- received F1-AP: UE Context Release Complete (SCell release/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell release/change)</li> <li>- received X2-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | integer(U32) | +| Measurement Type | OR.UEENDC.TotalDlCaUeScell10s. <i>Cnum</i> where <i>Cnum</i> is the number of CC:<br>0: #1CC (number of SCell excluding PSCell in the cell group)<br>1: #2CC (number of SCell excluding PSCell in the cell group)<br>...<br>6: #7CC (number of SCell excluding PSCell in the cell group) | +| Measurement Object Class | NRCelCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.10.9 Max DL CA UE Contexts PSCell (100ms) + +3 + +### A.10.9.1 Performance Counter Table + +| | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.MaxDlCaUePscell100ms | +| Description | This counter provides the maximum number of UE Contexts that are set of DL CA as PSCell in units of NR Cell. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.</p> <p>x is the number of the UE Contexts using this cell as PSCell per the number of CC configured for DL CA in unit of NR Cell group as subcounter.<i>Cnum</i>.</p> <p>The number is acquired as an instance value at every 100ms.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell addition)</li> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell addition/change)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell release)</li> <li>- received F1-AP: UE Context Release Complete (SCell release/change using SRB3)</li> </ul> </li> </ul> | + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Modification Confirm (SCell release/change)</li> <li>- received X2-AP: UE Context Release</li> </ul> | +| Measurement Result | Users (integer) | +| Measurement Type | OR.UEENDC.MaxDlCaUePscell100ms.Ccnum where <i>Ccnum</i> is the number of CC:<br>0: #0CC (number of SCell excluding PSCell in the cell group)<br>1: #1CC (number of SCell excluding PSCell in the cell group)<br>...<br>7: #7CC (number of SCell excluding PSCell in the cell group) | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.10.10 Max DL CA UE Contexts PSCell (10s) + +### 3 A.10.10.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.MaxDlCaUePscell10s | +| Description | This counter provides the maximum number of UE Contexts that are set of DL CA as PSCell in units of NR Cell. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 10s by the volume x, if x is bigger than previously counted volume.</p> <p>x is the number of the UE Contexts using this cell as PSCell per the number of CC configured for DL CA in unit of NR Cell group as subcounter. <i>Ccnum</i>.</p> <p>The number is acquired as an instance value at every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell addition)</li> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell addition/change)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell release)</li> <li>- received F1-AP: UE Context Release Complete (SCell release/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell release/change)</li> <li>- received X2-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | Users (integer) | +| Measurement Type | OR.UEENDC.MaxDlCaUePscell10s.Ccnum where <i>Ccnum</i> is the number of CC:<br>0: #0CC (number of SCell excluding PSCell in the cell group)<br>1: #1CC (number of SCell excluding PSCell in the cell group)<br>...<br>7: #7CC (number of SCell excluding PSCell in the cell group) | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | + +| | | +|------------|--------------------------------------------------| +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.10.11 Max DL CA UE Contexts SCell (100ms) + +### A.10.11.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.MaxDlCaUeScell100ms | +| Description | This counter provides the maximum number of UE Contexts that are set of DL CA as SCell in units of NR Cell. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.</p> <p>x is the number of the UE Contexts using this cell as SCell per the number of CC configured for DL CA in unit of NR Cell group as subcounter. <i>Ccnum</i>.</p> <p>The number is acquired as an instance value at every 100ms.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell addition)</li> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell addition/change)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell release)</li> <li>- received F1-AP: UE Context Release Complete (SCell release/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell release/change)</li> <li>- received X2-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | Users (integer) | +| Measurement Type | OR.UEENDC.MaxDlCaUeScell100ms. <i>Ccnum</i> where <i>Ccnum</i> is the number of CC:<br>0: #1CC (number of SCell excluding PSCell in the cell group)<br>1: #2CC (number of SCell excluding PSCell in the cell group)<br>...<br>7: #6CC (number of SCell excluding PSCell in the cell group) | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.10.12 Max DL CA UE Contexts SCell (10s) + +### A.10.12.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UEENDC.MaxDlCaUeScell10s | +| Description | This counter provides the maximum number of UE Contexts that are set of DL CA as SCell in units of NR Cell. | +| Collection Method | SI | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 10s by the volume x, if x is bigger than previously counted volume.</p> <p>x is the number of the UE Contexts using this cell as SCell per the number of CC configured for DL CA in unit of NR Cell group as subcounter. <i>Ccnum</i>.</p> <p>The number is acquired as an instance value at every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell addition)</li> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell addition/change)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received X2-AP: SgNB Reconfiguration Complete (SCell release)</li> <li>- received F1-AP: UE Context Release Complete (SCell release/change using SRB3)</li> <li>- received X2-AP: SgNB Modification Confirm (SCell release/change)</li> <li>- received X2-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | Users (integer) | +| Measurement Type | OR.UEENDC.MaxDlCaUeScell10s. <i>Ccnum</i> where <i>Ccnum</i> is the number of CC:<br>0: #1CC (number of SCell excluding PSCell in the cell group)<br>1: #2CC (number of SCell excluding PSCell in the cell group)<br>...<br>7: #6CC (number of SCell excluding PSCell in the cell group) | +| Measurement Object Class | NRCelLCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## A.11 Number of UE Contexts for SA + +### A.11.1 Total RRC Connected UE Contexts + +#### A.11.1.1 Performance Counter Table + +| | | +|-------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.TotalRrcConnectedUes | +| Description | This counter provides the total number of the RRC connected UE Contexts in PCell. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.</p> <p>x is the number of the RRC connected UE Contexts by every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received RRC: RRC Setup Complete</li> <li>- received RRC: RRC Reconfiguration Complete (Inter RAT HO to NR, Inter gNB-CU HO, Intra gNB-CU Inter gNB-DU HO, Intra-DU Inter Cell HO, RRC Connection Re-establishment)</li> </ul> </li> </ul> | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | (Intra gNB-CU Inter gNB-DU), RRC Connection Re-establishment (Intra gNB-DU Inter Cell)) <ul style="list-style-type: none"> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected)</li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO, RRC Connection Re-establishment (Inter gNB-CU))</li> <li>- received NG-AP: UE Context Release Command (Inter-RAT HO to LTE, Intra gNB-CU Inter gNB-DU HO, EPS fallback)</li> <li>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-Cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.TotalRrcConnectedUes | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.11.2 Total UE Contexts Per QoS + +### 3 A.11.2.1 Performance Counter Table + +| | | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.TotalUesCucountgroup | +| Description | This counter provides the total number of the UE Contexts per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.<br/>x is the number of the UE Contexts per CU count group for PCell and SCell as subcountner. <i>Celltype</i> by every 10s.</p> <p>Note: multiple 5QIs can be set per UE Context, each 5QI is counted per QoS flow.</p> <ul style="list-style-type: none"> <li>- the triggers of addition for PCell <ul style="list-style-type: none"> <li>- received NG-AP: Initial Context Setup Response</li> <li>- received RRC: RRC Reconfiguration Complete (Inter RAT HO to NR, Inter gNB-CU HO, Intra gNB-CU Inter gNB-DU HO, Intra-DU Inter Cell HO, RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU), RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected)</li> <li>- send NG-AP: PDU Session Resource Setup Response (PDU Session Establishment)</li> <li>- send NG-AP: PDU Session Resource Modify Response (PDU Session Modification)</li> </ul> </li> <li>- the triggers of subtraction for PCell <ul style="list-style-type: none"> <li>- send RRC: RRC Release (UE Context Release, RRC Connected to RRC inactive, SN Release without keeping UE)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO, RRC Connection Re-establishment (Inter gNB-CU))</li> <li>- received NG-AP: UE Context Release Command (Inter-RAT HO to LTE, Intra gNB-CU Inter gNB-DU HO, EPS fallback)</li> </ul> </li> </ul> | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-Cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received F1-AP: UE Context Release Command (RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU))</li> <li>- send NG-AP: PDU Session Resource Release Response (PDU Session Release)</li> <li>- send NG-AP: PDU Session Resource Modify Response (PDU Session Modification)</li> <li>- the triggers of addition for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change)</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected with SCell addition)</li> </ul> </li> <li>- the triggers of subtraction for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell release/change)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO w/ Xn)</li> <li>- received NG-AP: UE Context Release Command</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.TotalUesCucountgroup.Cucountgroup.Celltype where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. <i>Celltype</i> is the cell type:<br>0: PCell<br>1: SCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.11.3 Total SCell Configuration UE Contexts + +### 3 A.11.3.1 Performance Counter Table + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.TotalScellConfigUes.SCell | +| Description | This counter provides the total number of each SCell configuration UE Contexts. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.<br/>x is the number of each SCell configuration UE Contexts by every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change)</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected with SCell addition)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell release/change)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO w/ Xn)</li> <li>- received NG-AP: UE Context Release Command</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.TotalScellConfigUes.SCell | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.4 Total Measurement Gap UE Contexts + +### A.11.4.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.TotalMeasGapUes | +| Description | This counter provides the total number of UE Contexts which is configured with measurement gap. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.<br/>x is the number of UE Contexts which is configured measurement gap by every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (setup measurement gap)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (release measurement gap)</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.TotalMeasGapUes | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.5 Max RRC Connected UE Contexts + +### A.11.5.1 Performance Counter Table + +| | | +|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.MaxRrcConnectedUes | +| Description | This counter provides the maximum number of the RRC connected UE Contexts in PCell. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 10s by the volume x, if x is bigger than previously counted volume.<br/>x is the number of the RRC connected UE Contexts in PCell.<br/>The number is acquired as an instance value at every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received RRC: RRC Setup Complete</li> <li>- received RRC: RRC Reconfiguration Complete (Inter RAT HO to NR, Inter gNB-CU HO, Intra gNB-CU Inter gNB-DU HO, Intra-DU Inter Cell HO, RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU), RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected)</li> </ul> </li> </ul> | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>- the triggers of subtraction</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO, RRC Connection Re-establishment (Inter gNB-CU))</li> <li>- received NG-AP: UE Context Release Command (Inter-RAT HO to LTE, Intra gNB-CU Inter gNB-DU HO, EPS fallback)</li> <li>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-Cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.MaxRrcConnectedUes | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.11.6 Max UE Contexts Per QoS + +3 + +### A.11.6.1 Performance Counter Table + +| | | +|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.MaxUesPerCuCountgroup | +| Description | This counter provides the maximum number of the UE Contexts per CU count group. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 10s by the volume x, if x is bigger than previously counted volume. x is the number of the UE Contexts per CU count group for PCell and SCell as subcounter. <i>Celltype</i>.</p> <p>Note: multiple 5QIs can be set per UE Context, each 5QI is counted per QoS flow.</p> <ul style="list-style-type: none"> <li>- the triggers of addition for PCell <ul style="list-style-type: none"> <li>- received NG-AP: Initial Context Setup Response</li> <li>- received RRC: RRC Reconfiguration Complete (Inter RAT HO to NR, Inter gNB-CU HO, Intra gNB-CU Inter gNB-DU HO, Intra-DU Inter Cell HO, RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU), RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected)</li> <li>- send NG-AP: PDU Session Resource Setup Response (PDU Session Establishment)</li> <li>- send NG-AP: PDU Session Resource Modify Response (PDU Session Modification)</li> </ul> </li> <li>- the triggers of subtraction for PCell <ul style="list-style-type: none"> <li>- send RRC: RRC Release (UE Context Release, RRC Connected to RRC inactive, SN Release without keeping UE)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO, RRC Connection Re-establishment (Inter gNB-CU))</li> <li>- received NG-AP: UE Context Release Command (Inter-RAT HO to LTE, Intra gNB-CU Inter gNB-DU HO, EPS fallback)</li> <li>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-Cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received F1-AP: UE Context Release Command (RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU))</li> <li>- send NG-AP: PDU Session Resource Release Response (PDU Session Release)</li> </ul> </li> </ul> | + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>- send NG-AP: PDU Session Resource Modify Response (PDU Session Modification)</li> <li>- the triggers of addition for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change)</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected with SCell addition)</li> </ul> </li> <li>- the triggers of subtraction for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell release/change)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO w/ Xn)</li> <li>- received NG-AP: UE Context Release Command</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.MaxUesPerCuCountgroup.CuCountgroup.Celltype where <i>CuCountgroup</i> identifies an instance of CuCountGroup IOC. <i>Celltype</i> is the cell type:<br>0: PCell<br>1: SCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.11.7 Max SCell Configuration UE Contexts + +### 3 A.11.7.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.MaxScellConfigUes.SCell | +| Description | This counter provides the maximum number of each SCell configuration UE Contexts. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 10s by the volume x, if x is bigger than previously counted volume.</p> <p>x is the number of each SCell configuration UE Contexts.</p> <p>The number is acquired as an instance value at every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change)</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected with SCell addition)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell release/change)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO w/ Xn)</li> <li>- received NG-AP: UE Context Release Command</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.MaxScellConfigUes.SCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.8 Max Measurement Gap UE Contexts + +### A.11.8.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.MaxMeasGapUes | +| Description | This counter provides the maximum number of UE Contexts which is configured with measurement gap. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 10s by the volume x, if x is bigger than previously counted volume.</p> <p>x is the number of the UE Contexts which is configured with measurement gap.</p> <p>The number is acquired as an instance value at every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (setup measurement gap)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (release measurement gap)</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.MaxMeasGapUes | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.9 Total emergency UE Contexts + +### A.11.9.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.TotalEmergencyUes | +| Description | This counter provides the total number of the emergency UE Contexts in a Cell. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.</p> <p>x is the number of the emergency UE Contexts per PCell or SCell as subcounter. <i>Celltype</i> by every 10s.</p> <p>emergency UE Contexts: UE Contexts corresponding to ARP number assigned for emergency call or Establishment cause (or Resume cause): emergency is assigned.</p> <ul style="list-style-type: none"> <li>- the triggers of addition for PCell <ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received RRC: RRC Reconfiguration Complete (Inter RAT HO to NR, Inter gNB-CU HO, Intra gNB-CU Inter gNB-DU HO, Intra-DU Inter Cell HO, RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU), RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected)</li> </ul> </li> <li>- the triggers of subtraction for PCell</li> </ul> | + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>- send RRC: RRC Release (UE Context Release, RRC Connected to RRC inactive, SN Release without keeping UE)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO, RRC Connection Re-establishment (Inter gNB-CU))</li> <li>- received NG-AP: UE Context Release Command (Inter-RAT HO to LTE, Intra gNB-CU Inter gNB-DU HO, EPS fallback)</li> <li>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-Cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received F1-AP: UE Context Release Command (RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU))</li> <li>- the triggers of addition for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change)</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected with SCell addition)</li> </ul> </li> <li>- the triggers of subtraction for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell release/change)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO w/ Xn)</li> <li>- received NG-AP: UE Context Release Command</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.TotalEmergencyUes. <i>Celltype</i> where <i>Celltype</i> is the cell type:<br>0: PCell<br>1: SCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.10 Total high priority access UE Contexts + +### A.11.10.1 Performance Counter Table + +| | | +|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.TotalHighPriAccessUes | +| Description | This counter provides the total number of the high priority access UE Contexts in a Cell. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.</p> <p>x is the number of the high priority access UE Contexts per PCell or SCell as subcounter.<i>Celltype</i> by every 10s.</p> <p>high priority access UE Contexts: UE Contexts corresponding to ARP number assigned for high priority access call or Establishment cause (or Resume cause): highPriorityAccess is assigned.</p> <ul style="list-style-type: none"> <li>- the triggers of addition for PCell <ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received RRC: RRC Reconfiguration Complete (Inter RAT HO to NR, Inter gNB-CU HO, Intra gNB-CU Inter gNB-DU HO, Intra-DU Inter Cell HO, RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU), RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected)</li> </ul> </li> </ul> | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>- the triggers of subtraction for PCell <ul style="list-style-type: none"> <li>- send RRC: RRC Release (UE Context Release, RRC Connected to RRC inactive, SN Release without keeping UE)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO, RRC Connection Re-establishment (Inter gNB-CU))</li> <li>- received NG-AP: UE Context Release Command (Inter-RAT HO to LTE, Intra gNB-CU Inter gNB-DU HO, EPS fallback)</li> <li>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-Cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received F1-AP: UE Context Release Command (RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU))</li> </ul> </li> <li>- the triggers of addition for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change)</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected with SCell addition)</li> </ul> </li> <li>- the triggers of subtraction for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell release/change)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO w/ Xn)</li> <li>- received NG-AP: UE Context Release Command</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.TotalHighPriAccessUes <i>Celltype</i> where <i>Celltype</i> is the cell type:<br>0: PCell<br>1: SCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.11 Max emergency UE Contexts + +### A.11.11.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.MaxEmergencyUes | +| Description | This counter provides the maximum number of the Emergency UE Contexts in a Cell. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 10s by the volume x, if x is bigger than previously counted volume.</p> <p>X is the number of the emergency UE Contexts per PCell or SCell as subcounter. <i>Celltype</i>.</p> <p>The number is acquired as an instance value at every 10s.</p> <p>Emergency UE Contexts: UEs corresponding to ARP number assigned for emergency call or Establishment cause (or Resume cause): emergency is assigned.</p> <ul style="list-style-type: none"> <li>- the triggers of addition for PCell <ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received RRC: RRC Reconfiguration Complete (Inter RAT HO to NR, Inter gNB-CU HO, Intra gNB-CU Inter gNB-DU HO, Intra-DU Inter Cell HO, RRC Connection Re-establishment</li> </ul> </li> </ul> | + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | (Intra gNB-CU Inter gNB-DU), RRC Connection Re-establishment (Intra gNB-DU Inter Cell)) <ul style="list-style-type: none"> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected)</li> </ul> <ul style="list-style-type: none"> <li>- the triggers of subtraction for PCell <ul style="list-style-type: none"> <li>- send RRC: RRC Release (UE Context Release, RRC Connected to RRC inactive, SN Release without keeping UE)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO, RRC Connection Re-establishment (Inter gNB-CU))</li> <li>- received NG-AP: UE Context Release Command (Inter-RAT HO to LTE, Intra gNB-CU Inter gNB-DU HO, EPS fallback)</li> <li>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-Cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received F1-AP: UE Context Release Command (RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU))</li> </ul> </li> <li>- the triggers of addition for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change)</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected with SCell addition)</li> </ul> </li> <li>- the triggers of subtraction for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell release/change)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO w/ Xn)</li> <li>- received NG-AP: UE Context Release Command</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.MaxEmergencyUes <i>Celltype</i> where <i>Celltype</i> is the cell type:<br>0: PCell<br>1: SCell | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.12 Max high priority access UE Contexts + +### A.11.12.1 Performance Counter Table + +| | | +|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.MaxHighPriAccessUes | +| Description | This counter provides the maximum number of the high priority access UE Contexts in a Cell. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 10s by the volume x, if x is bigger than previously counted volume.</p> <p>x is the number of the high priority access UE Contexts per PCell or SCell as subcounter. <i>Celltype</i>.</p> <p>The number is acquired as an instance value at every 10s.</p> <p>high priority access UE Contexts: UE Contexts corresponding to ARP number assigned for high priority access call or Establishment cause (or Resume cause): highPriorityAccess is assigned.</p> <ul style="list-style-type: none"> <li>- the triggers of addition for PCell <ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> </ul> </li> </ul> | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (Inter RAT HO to NR, Inter gNB-CU HO, Intra gNB-CU Inter gNB-DU HO, Intra-DU Inter Cell HO, RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU), RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected)</li> <li>- the triggers of subtraction for PCell <ul style="list-style-type: none"> <li>- send RRC: RRC Release (UE Context Release, RRC Connected to RRC inactive, SN Release without keeping UE)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO, RRC Connection Re-establishment (Inter gNB-CU))</li> <li>- received NG-AP: UE Context Release Command (Inter-RAT HO to LTE, Intra gNB-CU Inter gNB-DU HO, EPS fallback)</li> <li>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-Cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received F1-AP: UE Context Release Command (RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU))</li> </ul> </li> <li>- the triggers of addition for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell addition/change)</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected with SCell addition)</li> </ul> </li> <li>- the triggers of subtraction for SCell <ul style="list-style-type: none"> <li>- received RRC: RRC Reconfiguration Complete (SCell release/change)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO w/ Xn)</li> <li>- received NG-AP: UE Context Release Command</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.MaxHighPriAccessUes <i>Celltype</i> where <i>Celltype</i> is the cell type:<br>0: PCell<br>1: SCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.11.13 Total SN terminated split bearer UE Contexts in NR-DC + +3 + +### A.11.13.1 Performance Counter Table + +| | | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UENRDC.TotalSnSplitbearUes | +| Description | This counter provides the total number of UE Contexts configured as SN terminated split bearer in the NR-DC. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.</p> <p>x is the number of the UE Contexts configured as SN terminated Split bearer in the NR-DC.</p> <p>The number is acquired as an instance value at every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition</li> </ul> | + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>- received Xn-AP: SN Reconfiguration Complete (to SN terminated split bearer)</li> <li>- received Xn-AP: S-Node Modification Confirm (Intra/Inter DU PSCell change using SRB1 (for target cell))</li> <li>- received RRC: RRC Reconfiguration Complete (Intra DU PSCell change using SRB3 (for target cell))</li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received Xn-AP: S-Node Modification Confirm (Intra/Inter DU PSCell change using SRB1 (for source cell))</li> <li>- received RRC: RRC Reconfiguration Complete (Intra DU PSCell change using SRB3 (for source cell))</li> <li>- received Xn-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UENRDC.TotalSnSplitbearUes | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.11.14 Max SN terminated split bearer UE Contexts in NR-DC + +3 + +### A.11.14.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UENRDC.MaxSnSplitbearUes | +| Description | This counter provides the maximum number of UE Contexts configured as SN terminated split bearer in the NR-DC. | +| Collection Method | SI | +| Condition | <p>Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.</p> <p>x is the number of the UE Contexts configured as SN terminated split bearer in the NR-DC.</p> <p>x is acquired as an instantaneous value at every 100ms.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- received Xn-AP: SN Reconfiguration Complete (to SN terminated split bearer)</li> <li>- received Xn-AP: S-Node Modification Confirm (Intra/Inter DU PSCell change using SRB1 (for target cell))</li> <li>- received RRC: RRC Reconfiguration Complete (Intra DU PSCell change using SRB3 (for target cell))</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- received Xn-AP: S-Node Modification Confirm (Intra/Inter DU PSCell change using SRB1 (for source cell))</li> <li>- received RRC: RRC Reconfiguration Complete (Intra DU PSCell change using SRB3 (for source cell))</li> <li>- received Xn-AP: UE Context Release</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UENRDC.MaxSnSplitbearUes | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## A.11.15 Total UE Contexts during voice call + +### A.11.15.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.UESA.TotalUesVoice | +| Description | This counter provides the total number of the UE Contexts during voice call. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is the total number of x by the measurement period.<br/>x is the number of the UE Contexts during voice call by every 10s.</p> <ul style="list-style-type: none"> <li>- the triggers of addition <ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received RRC: RRC Reconfiguration Complete (Inter RAT HO to NR, Inter gNB-CU HO, Intra gNB-CU Inter gNB-DU HO, Intra-DU Inter Cell HO, RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU), RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received RRC: RRC Resume Complete (RRC inactive to RRC Connected)</li> </ul> </li> <li>- the triggers of subtraction <ul style="list-style-type: none"> <li>- send RRC: RRC Release (UE Context Release, RRC Connected to RRC inactive, SN Release without keeping UE)</li> <li>- received Xn-AP: UE Context Release (Inter gNB-CU HO, RRC Connection Re-establishment (Inter gNB-CU))</li> <li>- received NG-AP: UE Context Release Command (Inter-RAT HO to LTE, Intra gNB-CU Inter gNB-DU HO, EPS fallback)</li> <li>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-Cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter Cell))</li> <li>- received F1-AP: UE Context Release Command (RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU))</li> </ul> </li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.UESA.TotalUesVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12 Monitoring of procedure for EN-DC + +### A.12.1 Number of SgNB Addition procedure attempted for each Cell + +#### A.12.1.1 Performance Counter Table + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ENDCPROCEDURE.SgnbAddAttemptCell | +| Description | This counter provides the number of the transmitted X2-AP:SGNB ADDITION REQUEST ACKNOWLEDGE messages. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever X2-AP:SGNB ADDITION REQUEST ACKNOWLEDGE message is transmitted as PSCell. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ENDCPROCEDURE.SgnbAddAttemptCell | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.2 Number of SgNB Addition procedure successfully for each Cell + +### A.12.2.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ENDCPROCEDURE.SgnbAddSuccessCell | +| Description | This counter provides the number of the completed SgNB addition Procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever SgNB addition procedure is completed as PSCell (i.e. X2-AP:SGNB RECONFIGURATION COMPLETE message (SgNB addition complete) is received and RACH processing with UE is completed). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ENDCPROCEDURE.SgnbAddSuccessCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.3 Number of SgNB Addition procedure attempted for each neighbour eNB + +### A.12.3.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ENDCPROCEDURE.SgnbAddAttemptNeiEnb | +| Description | This counter provides the number of the transmitted X2-AP:SGNB ADDITION REQUEST ACKNOWLEDGE messages.<br>This counter is split into subcounters per neighbour eNB. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever X2-AP:SGNB ADDITION REQUEST ACKNOWLEDGE message is transmitted when the eNB configured by the message is group of subcounter <i>neighbourNB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ENDCPROCEDURE.SgnbAddAttemptNeiEnb. <i>neighbourNB</i><br>where <i>neighbourNB</i> is neighbour eNB index:<br><br>0: #0<br><br>1: #1<br><br>...<br>63: #63 | +| Measurement Object Class | GNBCUCPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.4 Number of SgNB Addition procedure successfully for each neighbour eNB + +### A.12.4.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ENDCPROCEDURE.SgnbAddSuccessNeiEnb | +| Description | This counter provides the number of the completed SgNB addition Procedure.<br>This counter is split into subcounters per neighbour eNB. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever SgNB addition procedure is completed (i.e. X2-AP:SGNB RECONFIGURATION COMPLETE message (SgNB addition complete) is received and RACH processing with UE is completed) when the eNB configured by the message is group of subcounter. <i>neighboureNB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ENDCPROCEDURE.SgnbAddSuccessNeiEnb. <i>neighboureNB</i><br>where <i>neighboureNB</i> is neighbour eNB index:<br><br>0: #0<br><br>1: #1<br><br>...<br>63: #63 | +| Measurement Object Class | GNBCUCPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.5 Number of SgNB modification procedure attempted for each neighbour eNB + +### A.12.5.1 Performance Counter Table + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ENDCPROCEDURE.SgnbModAttemptNeiEnb | +| Description | This counter provides the number of the received X2-AP:SGNB MODIFICATION REQUEST messages or transmitted X2-AP:SGNB MODIFICATION REQUIRED messages.<br>This counter is split into subcounters per neighbour eNB. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever X2-AP:SGNB MODIFICATION REQUEST message is received or X2-AP:SGNB MODIFICATION REQUIRED message is transmitted , when the eNB configured by the message is group of subcounter. <i>neighboureNB</i> .<br>Double counting is not performed if the procedure is changed to the MN initiated SN Modification procedure after transmitted X2-AP:SGNB MODIFICATION REQUIRED message (e.g. Measurement gap Coordination(SN initiated)).<br><br>This subcounter will not be incremented if received X2-AP:SGNB MODIFICATION REQUEST message which True is set for SCG Configuration Query IE. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ENDCPROCEDURE.SgnbModAttemptNeiEnb. <i>neighboureNB</i><br>where <i>neighboureNB</i> is neighbour eNB index: | + +| | | +|--------------------------|--------------------------------------------------| +| | 0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | GNBCUCPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.6 Number of SgNB modification procedure successfully for each neighbour eNB + +### A.12.6.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ENDCPROCEDURE.SgnbModSuccessNeiEnb | +| Description | This counter provides the number of the completed SgNB modification Procedure.<br>This counter is split into subcounters per neighbour eNB. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever SgNB Modification procedure is completed (i.e. X2-AP:SGNB RECONFIGURATION COMPLETE message(SgNB modification complete) is received or X2-AP:SGNB MODIFICATION CONFIRM is received and RACH processing with UE is completed) when the eNB configured by the message is group of subcounter. <i>neighboureNB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ENDCPROCEDURE.SgnbModSuccessNeiEnb. <i>neighboureNB</i><br>where <i>neighboureNB</i> is neighbour eNB index:<br><br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | GNBCUCPFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13 Monitoring of RRC Connection for EN-DC + +### A.13.1 Number of Measurement Gap Coordination for per FR2 gap via SRB3 attempted + +#### A.13.1.1 Performance Counter Table + +| | | +|------------------|-----------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONENDC.ReconfSrb3AttemptGap | +| Description | This counter provides the number of the transmitted RRC:RRC Reconfiguration messages via SRB3 when the following procedure. | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | - Measurement Gap Coordination for per FR2 gap (without MN involvement) Procedure (SN initiated). | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC:RRCReconfiguration message is transmitted via SRB3 when the following procedure.<br>- Measurement Gap Coordination for per FR2 gap (without MN involvement) Procedure (SN initiated). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONENDC.ReconfSrb3AttemptGap | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.2 Number of Measurement Gap Coordination for per FR2 gap via SRB3 successfully + +### A.13.2.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONENDC.ReconfSrb3SuccessGap | +| Description | This counter provides the number of the received RRC:RRC Reconfiguration Complete messages via SRB3 when the following procedure.<br>- Measurement Gap Coordination for per FR2 gap (without MN involvement) Procedure (SN initiated). | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC:RRCReconfiguration Complete message is received via SRB3 when the following procedure.<br>- Measurement Gap Coordination for per FR2 gap (without MN involvement) Procedure (SN initiated). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONENDC.ReconfSrb3SuccessGap | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.3 Number of Inter gNB-DU PSCell Change via SRB3 attempted + +### A.13.3.1 Performance Counter Table + +| | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONENDC.ReconfSrb3AttemptInterDuPscellch | +| Description | This counter provides the number of the transmitted RRC:RRC Reconfiguration messages via SRB3 when the following procedure.<br>- Inter gNB-DU PSCell Change using SRB3 for RRC Reconfiguration | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC:RRCReconfiguration message is transmitted via SRB3 when the following procedure. | + +| | | +|--------------------------|------------------------------------------------------------------| +| | - Inter gNB-DU PSCell Change using SRB3 for RRC Reconfiguration. | +| Measurement Result | Integer number (32) | +| Measurement Type | OR.RRCCONENDC.ReconfSrb3AttemptInterDuPscellch | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.13.4 Number of Inter gNB-DU PSCell Change via SRB3 successfully + +3 + +### A.13.4.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONENDC.ReconfSrb3SuccessInterDuPscellch | +| Description | This counter provides the number of the received RRC:RRC Reconfiguration Complete messages via SRB3 when the following procedure.<br>- Inter gNB-DU PSCell Change using SRB3 for RRC Reconfiguration. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC:RRCReconfiguration Complete message is received via SRB3 when the following procedure.<br>- Inter gNB-DU PSCell Change using SRB3 for RRC Reconfiguration. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONENDC.ReconfSrb3SuccessInterDuPscellch | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +5 + +## A.13.5 Number of Intra gNB-DU PSCell Change via SRB3 attempted + +6 + +### A.13.5.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONENDC.ReconfSrb3AttemptIntraDuPscellch | +| Description | This counter provides the number of the transmitted RRC:RRC Reconfiguration messages via SRB3 when the following procedure.<br>- Intra gNB-DU PSCell Change using SRB3 for RRC Reconfiguration. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC:RRCReconfiguration message is transmitted via SRB3 when the following procedure.<br>- Intra gNB-DU PSCell Change using SRB3 for RRC Reconfiguration. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONENDC.ReconfSrb3AttemptIntraDuPscellch | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +7 + +## A.13.6 Number of Intra gNB-DU PSCell Change via SRB3 successfully + +### A.13.6.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONENDC.ReconfSrb3SuccessIntraDuPscellch | +| Description | This counter provides the number of the received RRC:RRC Reconfiguration Complete messages via SRB3 when the following procedure.<br>- Intra gNB-DU PSCell Change using SRB3 for RRC Reconfiguration. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC:RRCReconfiguration Complete message is received via SRB3 when the following procedure.<br>- Intra gNB-DU PSCell Change using SRB3 for RRC Reconfiguration. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONENDC.ReconfSrb3SuccessIntraDuPscellch | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.14 Monitoring of RRC Connection for SA + +### A.14.1 Number of initial RRC Connection requests + +#### A.14.1.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONSA.IniConReq | +| Description | This counter provides the number of the received RRC: RRC Setup Request (or RRC: RRC Resume Request) messages via F1-C which is in the first time for each ue-Identity. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Request (or RRC: RRC Resume Request) message is received via F1-C, if RRC: RRC Setup Request (or RRC: RRC Resume Request) message of the same ue-Identity is not received for a certain period of time from the reception timing. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONSA.IniConReq | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.14.2 Number of RRC connection completions for initial RRC Connection requests + +#### A.14.2.1 Performance Counter Table + +| | | +|------------------|------------------------| +| Measurement Name | OR.RRCCONSA.IniConComp | +|------------------|------------------------| + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Description | This counter provides the number of the received RRC: RRC Setup Complete (or RRC: RRC Resume Response) messages via F1-C which corresponds to the initial RRC: RRC Setup Request (or RRC: RRC Resume Request) except fall-back procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Complete (or RRC: RRC Resume Response) message which corresponds to the initial RRC: RRC Setup Request (or RRC: RRC Resume Request) except fall-back procedure is received via F1-C. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONSA.IniConComp | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.14.3 Number of retransmission RRC Connections requests + +### 3 A.14.3.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONSA.RetConReq | +| Description | This counter provides the number of the received RRC: RRC Setup Request (or RRC: RRC Resume Request) messages via F1-C which is retransmission for each ue-Identity. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Request (or RRC: RRC Resume Request) message is received via F1-C, if RRC: RRC Setup Request (or RRC: RRC Resume Request) message of the same ue-Identity is received for a certain period of time from the reception timing. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONSA.RetConReq | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## 5 A.14.4 Number of RRC Connections completions for retransmission RRC 6 Connections requests + +### 7 A.14.4.1 Performance Counter Table + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONSA.RetransConComp | +| Description | This counter provides the number of the received RRC: RRC Setup Complete (or RRC: RRC Resume Response) messages via F1-C which corresponds to the retransmission RRC: RRC Setup Request (or RRC: RRC Resume Request) except fall-back procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Complete (or RRC: RRC Resume Response) message which corresponds to the retransmission RRC: RRC Setup Request (or RRC: RRC Resume Request) except fall-back procedure is received via F1-C. | +| Measurement Result | Integer number (U32) | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Type | OR.RRCCONSA.RetransConComp | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.14.5 Number of incomplete RRC Connection by failed resource allocations + +### A.14.5.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONSA.IncompConResourAllo | +| Description | This counter provides the number of the RRC Connection configuration interrupted by failed resource allocations. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC Connection configuration is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to RRC: RRC Setup Complete (or RRC: RRC Resume Complete) by failed resource allocations. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONSA.IncompConResourAllo | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.14.6 Number of incomplete RRC Connection by O-CU internal error + +### A.14.6.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONSA.IncompConOcuInterErr | +| Description | This counter provides the number of the RRC Connection configuration interrupted by O-CU internal error (e.g. L3 message sending NG). | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC Connection configuration is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to RRC: RRC Setup Complete (or RRC: RRC Resume Complete) by O-CU internal error. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONSA.IncompConOcuInterErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.14.7 Number of initial RRC Connection requests each Establishment Cause + +### A.14.7.1 Performance Counter Table + +| | | +|------------------|--------------------------------| +| Measurement Name | OR.RRCCONSA.IniConReqEstaCause | +|------------------|--------------------------------| + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Description | This counter provides the number of the received RRC: RRC Setup Request (or RRC: RRC Resume Request) messages via F1-C which is in the first time for each ue-Identity.<br>This counter is split into subcounters per EstablishmentCause. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC: RRC Setup Request (or RRC: RRC Resume Request) message is received via F1-C, if RRC: RRC Setup Request (or RRC: RRC Resume Response) message of the same ue-Identity is not received for a certain period of time from the reception timing when the cell configured by the message is group of subcounter. <i>EstablishmentCause</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONSA.IniConReqEstaCause. <i>EstablishmentCause</i> where <i>EstablishmentCause</i> is EstablishmentCause:<br><br>0: EstablishmentCause = emergency<br><br>1: EstablishmentCause = highPriorityAccess<br><br>2: EstablishmentCause = mt-Access<br><br>3: EstablishmentCause = mo-Signalling<br><br>4: EstablishmentCause = mo-Data<br><br>5: EstablishmentCause = mo-VoiceCall<br><br>6: EstablishmentCause = mo-VideoCall<br><br>7: EstablishmentCause = mo-SMS<br><br>8: EstablishmentCause = mps-PriorityAccess<br><br>9: EstablishmentCause = mcs-PriorityAccess | +| Measurement Object Class | NRCelCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## A.14.8 Number of RRC connection completions for initial RRC Connection requests each Establishment Cause + +3 + +### A.14.8.1 Performance Counter Table + +4 + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONSA.IniConCompEstaCause | +| Description | This counter provides the number of the received RRC: RRC Setup Complete (or RRC: RRC Resume Response) messages via F1-C which corresponds to the initial RRC: RRC Setup Request (or RRC: RRC Resume Request) except fall-back procedure.<br>This counter is split into subcounters per EstablishmentCause. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC:RRC Setup Complete (or RRC: RRC Resume Response) message which corresponds to the initial RRC: RRC Setup Request (or RRC: RRC Resume Request) except fall-back procedure is received via F1-C when the cell configured by the message is group of subcounter. <i>EstablishmentCause</i> . | +| Measurement Result | Integer number (U32) | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Type | OR.RRCONSA.IniConCompEstaCause. <i>EstablishmentCause</i> where <i>EstablishmentCause</i> is EstablishmentCause:<br><br>0: EstablishmentCause = emergency<br><br>1: EstablishmentCause = highPriorityAccess<br><br>2: EstablishmentCause = mt-Access<br><br>3: EstablishmentCause = mo-Signalling<br><br>4: EstablishmentCause = mo-Data<br><br>5: EstablishmentCause = mo-VoiceCall<br><br>6: EstablishmentCause = mo-VideoCall<br><br>7: EstablishmentCause = mo-SMS<br><br>8: EstablishmentCause = mps-PriorityAccess<br><br>9: EstablishmentCause = mcs-PriorityAccess | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +3 + +## A.14.9 Number of retransmission RRC Connections requests each Establishment Cause + +4 + +### A.14.9.1 Performance Counter Table + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCONSA.RetransConReqEstaCause | +| Description | This counter provides the number of the received RRC: RRC Setup Request (or RRC: RRC Resume Request) messages via F1-C which is retransmission for each ue-Identity.<br>This counter is split into subcounters per EstablishmentCause. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC: RRC Setup Request (or RRC: RRC Resume Request) message is received via F1-C, if RRC: RRC Setup Request (or RRC: RRC Resume Request) message of the same ue-Identity is received for a certain period of time from the reception timing when the cell configured by the message is group of subcounter. <i>EstablishmentCause</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCONSA.RetransConReqEstaCause. <i>EstablishmentCause</i> where <i>EstablishmentCause</i> is EstablishmentCause:<br><br>0: EstablishmentCause = emergency<br><br>1: EstablishmentCause = highPriorityAccess<br><br>2: EstablishmentCause = mt-Access<br><br>3: EstablishmentCause = mo-Signalling<br><br>4: EstablishmentCause = mo-Data<br><br>5: EstablishmentCause = mo-VoiceCall | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | 6: EstablishmentCause = mo-VideoCall<br>7: EstablishmentCause = mo-SMS<br>8: EstablishmentCause = mps-PriorityAccess<br>9: EstablishmentCause = mcs-PriorityAccess | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +3 + +## A.14.10 Number of RRC Connections completions for retransmission RRC Connections requests each Establishment Cause + +4 + +### A.14.10.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONSA.RetransConCompEstaCause | +| Description | This counter provides the number of the received RRC: RRC Setup Complete (or RRC: RRC Resume Response) messages via F1-C which corresponds to the retransmission RRC: RRC Setup Request (or RRC: RRC Resume Request) except fall-back procedure.<br>This counter is split into subcounters per EstablishmentCause. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC: RRC Setup Complete (or RRC: RRC Resume Response) message which corresponds to the retransmission RRC: RRC Setup Request (or RRC: RRC Resume Request) except fall-back procedure is received via F1-C when the cell configured by the message is group of subcounter. <i>EstablishmentCause</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONSA.RetransConCompEstaCause. <i>EstablishmentCause</i> where <i>EstablishmentCause</i> is EstablishmentCause:<br><br>0: EstablishmentCause = emergency<br>1: EstablishmentCause = highPriorityAccess<br>2: EstablishmentCause = mt-Access<br>3: EstablishmentCause = mo-Signalling<br>4: EstablishmentCause = mo-Data<br>5: EstablishmentCause = mo-VoiceCall<br>6: EstablishmentCause = mo-VideoCall<br>7: EstablishmentCause = mo-SMS<br>8: EstablishmentCause = mps-PriorityAccess<br>9: EstablishmentCause = mcs-PriorityAccess | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | + +| | | +|---------|--------------------------------------------------| +| Purpose | Network Operator's Traffic Engineering Community | +|---------|--------------------------------------------------| + +## A.14.11 Number of incomplete RRC Connection by failed resource allocations each Establishment Cause + +### A.14.11.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONSA.IncompConResourAlloEstaCause | +| Description | This counter provides the number of the RRC Connection configuration interrupted by failed resource allocations.<br>This counter is split into subcounters per EstablishmentCause. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC Connection configuration is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to RRC: RRC Setup Complete (or RRC: RRC Resume Complete) by failed resource allocations when the cell configured by the message is group of subcounter. <i>EstablishmentCause</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONSA.IncompConResourAlloEstaCause. <i>EstablishmentCause</i> where <i>EstablishmentCause</i> is EstablishmentCause:<br><br>0: EstablishmentCause = emergency<br>1: EstablishmentCause = highPriorityAccess<br>2: EstablishmentCause = mt-Access<br>3: EstablishmentCause = mo-Signalling<br>4: EstablishmentCause = mo-Data<br>5: EstablishmentCause = mo-VoiceCall<br>6: EstablishmentCause = mo-VideoCall<br>7: EstablishmentCause = mo-SMS<br>8: EstablishmentCause = mps-PriorityAccess<br>9: EstablishmentCause = mcs-PriorityAccess | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.14.12 Number of incomplete RRC Connection by O-CU internal error each Establishment Cause + +### A.14.12.1 Performance Counter Table + +| | | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRCCONSA.IncompConOcuInterErrEstaCause | +| Description | This counter provides the number of the RRC Connection configuration interrupted by O-CU internal error (e.g. L3 message sending NG).<br>This counter is split into subcounters per EstablishmentCause. | + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC Connection configuration is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to RRC: RRC Setup Complete (or RRC: RRC Resume Complete) by O-CU internal error when the cell configured by the message is group of subcounter. <i>EstablishmentCause</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RRCCONSA.IncompConOcuInterErrEstaCause. <i>EstablishmentCause</i> where <i>EstablishmentCause</i> is EstablishmentCause:<br><br>0: EstablishmentCause = emergency<br><br>1: EstablishmentCause = highPriorityAccess<br><br>2: EstablishmentCause = mt-Access<br><br>3: EstablishmentCause = mo-Signalling<br><br>4: EstablishmentCause = mo-Data<br><br>5: EstablishmentCause = mo-VoiceCall<br><br>6: EstablishmentCause = mo-VideoCall<br><br>7: EstablishmentCause = mo-SMS<br><br>8: EstablishmentCause = mps-PriorityAccess<br><br>9: EstablishmentCause = mcs-PriorityAccess | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15 Monitoring of Establishment calls for SA + +### A.15.1 Number of attempted establishment calls for mo-Data + +#### A.15.1.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.AttemptModata | +| Description | This counter provides the number of the received RRC: RRC Setup Complete (or RRC: RRC Resume Complete) messages via F1-C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (Resume Cause):mo-Data). | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Complete (or RRC: RRC Resume Complete) message is received via F1-C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mo-Data). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.AttemptModata | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | + +| | | +|---------|--------------------------------------------------| +| Purpose | Network Operator's Traffic Engineering Community | +|---------|--------------------------------------------------| + +## A.15.2 Number of successful establishment calls for mo-Data + +### A.15.2.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.SuccessModata | +| Description | This counter provides the number of the following message after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mt-Data): <ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received NG-AP: UE Context Release Command (for deregistration) before sending NG-AP: Initial Context Setup Response</li> </ul> | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever the following event occurs after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mo-Data): <ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received NG-AP: UE Context Release Command (for deregistration) before sending NG-AP: Initial Context Setup Response</li> </ul> Measurement counter is incremented by 1 whenever NG-AP:Initial Context Setup Response message is transmitted after received RRC: RRC Setup Request (Establishment Cause: mo-Data). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.SuccessModata | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.3 Number of incomplete establishment calls for mo-Data by protocol error + +### A.15.3.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompModataProtocolErr | +| Description | This counter provides the number of the Call establishment for mo-Data interrupted by protocol error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever Call establishment for mo-Data is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by protocol error. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompModataProtocolErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.4 Number of incomplete establishment calls for mo-Data by O-CU internal error + +### A.15.4.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompModataOcuInterErr | +| Description | This counter provides the number of the call establishment for mo-Data interrupted by O-CU internal error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for mo-Data is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-CU internal error. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompModataOcuInterErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.5 Number of incomplete establishment calls for mo-Data by O-DU error detection + +### A.15.5.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompModataOduErrDetect | +| Description | This counter provides the number of the call establishment for mo-Data interrupted by O-DU Error Detection. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for mo-Data is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-DU Error Detection. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompModataOduErrDetect | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.6 Number of attempted establishment calls for mt-Access + +### A.15.6.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.AttemptMtaccess | +| Description | This counter provides the number of the received RRC: RRC Setup Complete (or RRC: RRC Resume Complete) messages via F1-C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mt-Access). | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Complete (or RRC: RRC Resume Complete) message is received via F1- | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------| +| | C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mt-Access). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.AttemptMtaccess | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.15.7 Number of successful establishment calls for mt-Access + +3 + +### A.15.7.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.SuccessMtaccess | +| Description | This counter provides the number of the following message after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause):mt-Access):<br><ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received NG-AP: UE Context Release Command (for deregistration) before sending NG-AP: Initial Context Setup Response</li> </ul> | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever the following event occurs after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause):mt-Access):<br><ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received NG-AP: UE Context Release Command (for deregistration) before sending NG-AP: Initial Context Setup Response</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.SuccessMtaccess | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +5 + +## A.15.8 Number of incomplete establishment calls for mt-Access by protocol error + +6 + +7 + +### A.15.8.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompMtaccessProtocolErr | +| Description | This counter provides the number of the call establishment for mt-Access interrupted by protocol error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for mt-Access is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by protocol error. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompMtaccessProtocolErr | +| Measurement Object Class | NRCellCU | + +| | | +|----------------------|--------------------------------------------------| +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.9 Number of incomplete establishment calls for mt-Access by O-CU internal error + +### A.15.9.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompMtaccessOcuInterErr | +| Description | This counter provides the number of the call establishment for mt-Access interrupted by O-CU internal error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for mt-Access is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-CU internal error. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompMtaccessOcuInterErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.10 Number of incomplete establishment calls for mt-Access by O-DU error detection + +### A.15.10.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompMtaccessOduErrDetect | +| Description | This counter provides the number of the call establishment for mt-Access is interrupted by O-DU Error Detection. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for mt-Access is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by DU Error Detection. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompMtaccessOduErrDetect | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.11 Number of attempted establishment calls for mo-Signalling + +### A.15.11.1 Performance Counter Table + +| | | +|------------------|--------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.AcceptMosignal | +| Description | This counter provides the number of the received RRC: RRC Setup Complete (or RRC: RRC Resume Complete) messages via F1-C after | + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause):mo-Signalling). | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Complete (or RRC: RRC Resume Complete) message is received via F1-C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause):mo-Signalling). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.AcceptMosignal | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.12 Number of successful establishment calls for mo-Signalling + +### A.15.12.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.SuccessMosignal | +| Description | This counter provides the number of the following message after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mo-Signalling):<br><ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received NG-AP: UE Context Release Command (for deregistration) before sending NG-AP: Initial Context Setup Response</li> </ul> | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever the following event occurs after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mo-Signalling):<br><ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received NG-AP: UE Context Release Command (for deregistration) before sending NG-AP: Initial Context Setup Response</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.SuccessMosignal | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.13 Number of incomplete establishment calls for mo-Signalling by protocol error + +### A.15.13.1 Performance Counter Table + +| | | +|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompMosignalProtocolErr | +| Description | This counter provides the number of the call establishment for mo-Signalling interrupted by protocol error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for mo-Signalling is interrupted between RRC: RRC Setup Request (or | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------| +| | RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by protocol error. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompMosignalProtocolErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## A.15.14 Number of incomplete establishment calls for mo-Signalling by O-CU internal error + +3 + +### A.15.14.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompMosignalOcuInterErr | +| Description | This counter provides the number of the call establishment for mo-Signalling interrupted by O-CU internal error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever mo-Signalling configuration is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-CU internal error. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompMosignalOcuInterErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +5 + +## A.15.15 Number of incomplete establishment calls for mo-Signalling by O-DU error detection + +7 + +### A.15.15.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompMosignalDuErrDetect | +| Description | This counter provides the number of the call establishment for mo-Signalling interrupted by O-DU error detection. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for mo-Signalling is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-DU error detection. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompMosignalDuErrDetect | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +9 + +## A.15.16 Number of attempted establishment calls for mo-SMS + +### A.15.16.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.AttemptMossm | +| Description | This counter provides the number of the received RRC: RRC Setup Complete (or RRC: RRC Resume Complete) messages via F1-C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mo-SMS). | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Complete (or RRC: RRC Resume Complete) message is received via F1-C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mo-SMS). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.AttemptMossm | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.17 Number of successful establishment calls for mo-SMS + +### A.15.17.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.SuccessMossm | +| Description | This counter provides the number of the following message after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mo-SMS):<br><ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received NG-AP: UE Context Release Command (for deregistration) before sending NG-AP: Initial Context Setup Response</li> </ul> | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever the following event occurs after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): mo-SMS):<br><ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- received NG-AP: UE Context Release Command (for deregistration) before sending NG-AP: Initial Context Setup Response</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.SuccessMossm | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.18 Number of incomplete establishment calls for mo-SMS by protocol error + +### A.15.18.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompMossmProtocolErr | +| Description | This counter provides the number of the call establishment for mo-SMS interrupted by protocol error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for mo-SMS is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by protocol error. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompMossmProtocolErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.19 Number of incomplete establishment calls for mo-SMS by O-CU internal error + +### A.15.19.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompMossmOcuInterErr | +| Description | This counter provides the number of the call establishment for mo-SMS interrupted by O-CU internal error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for mo-SMS is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-CU internal error. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompMossmOcuInterErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.20 Number of incomplete establishment calls for mo-SMS by O-DU error detection + +### A.15.20.1 Performance Counter Table + +| | | +|-------------------|---------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompMossmOduErrDetect | +| Description | This counter provides the number of the call establishment for mo-SMS interrupted by O-DU error detection. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for mo-SMS is interrupted between RRC: RRC Setup Request (or RRC: | + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------| +| | RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-DU error detection. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompMossmsOduErrDetect | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.15.21 Number of attempted establishment calls for high priority access + +3 + +### A.15.21.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.AttemptHighPriAccess | +| Description | This counter provides the number of the received RRC: RRC Setup Complete messages (or RRC: RRC Resume Complete) via F1-C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): highPriorityAccess). | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Complete (or RRC: RRC Resume Complete) message is received via F1-C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): highPriorityAccess). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.AttemptHighPriAccess | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +5 + +## A.15.22 Number of successful establishment calls for high priority access + +6 + +### A.15.22.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.SuccessHighPriAccess | +| Description | This counter provides the number of the following message after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): highPriorityAccess):<br><ul style="list-style-type: none"> <li>- NG-AP: Initial Context Setup Response is transmitted.</li> <li>- NG-AP: UE Context Release Command (for detach) is received before NG-AP: Initial Context Setup Response is transmitted.</li> </ul> | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever the following event occurs after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): highPriorityAccess):<br><ul style="list-style-type: none"> <li>- send NG-AP: Initial Context Setup Response</li> <li>- NG-AP: UE Context Release Command (for detach) is received before NG-AP: Initial Context Setup Response is transmitted.</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.SuccessHighPriAccess | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | + +| | | +|------------|--------------------------------------------------| +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.23 Number of incomplete establishment calls for high priority access by protocol error + +### A.15.23.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompHighPriAccessProtocolErr | +| Description | This counter provides the number of the call establishment for high priority access interrupted by protocol error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for high priority access is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by protocol error (Call acceptance condition of CU/DU is not met). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompHighPriAccessProtocolErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.24 Number of incomplete establishment calls for high priority access by O-CU internal error + +### A.15.24.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompHighPriAccessOcuInterErr | +| Description | This counter provides the number of the call establishment for high priority access interrupted by O-CU internal error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for high priority access is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-CU internal error (Call acceptance condition of CU/DU is not met). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompHighPriAccessOcuInterErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.25 Number of incomplete establishment calls for high priority access by O-DU error detection + +### A.15.25.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompHighPriAccessOduErrDetect | +| Description | This counter provides the number of the call establishment for high priority access interrupted by O-DU error detection. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for high priority access is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-DU error detection (Call acceptance condition of CU/DU is not met). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompHighPriAccessOduErrDetect | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.26 Number of attempted establishment calls for emergency + +### A.15.26.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.AttemptEmergency | +| Description | This counter provides the number of the received RRC: RRC Setup Complete (or RRC: RRC Resume Complete) messages via F1-C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): emergency). | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Complete (or RRC: RRC Resume Complete) message is received via F1-C after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): emergency). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.AttemptEmergency | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.27 Number of successful establishment calls for emergency + +### A.15.27.1 Performance Counter Table + +| | | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.SuccessEmergency | +| Description | This counter provides the number of the following message after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): emergency):<br>- send NG-AP: Initial Context Setup Response | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | - NG-AP: UE Context Release Command (for detach) is received before NG-AP: Initial Context Setup Response is transmitted. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever the following event occurs after received RRC: RRC Setup Request (or RRC: RRC Resume Request) (Establishment Cause (or Resume Cause): emergency):<br>- NG-AP: Initial Context Setup Response is transmitted.<br>- NG-AP: UE Context Release Command (for detach) is received before NG-AP: Initial Context Setup Response is transmitted. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.SuccessEmergency | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.28 Number of incomplete establishment calls for emergency by protocol error + +### A.15.28.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompEmergencyProtocolErr | +| Description | This counter provides the number of the call establishment for emergency interrupted by protocol error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for emergency is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by protocol error (Call acceptance condition of CU/DU is not met). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompEmergencyProtocolErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.29 Number of incomplete establishment calls for emergency by O-CU internal error + +### A.15.29.1 Performance Counter Table + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompEmergencyOcuInterErr | +| Description | This counter provides the number of the call establishment for emergency interrupted by O-CU internal error. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for emergency is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-CU internal error (Call acceptance condition of CU/DU is not met). | +| Measurement Result | Integer number (U32) | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Type | OR.ESTACALL.IncompEmergencyOcuInterErr | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.30 Number of incomplete establishment calls for emergency by O-DU error detection + +### A.15.30.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ESTACALL.IncompEmergencyOduErrDetect | +| Description | This counter provides the number of the call establishment for emergency interrupted by O-DU error detection. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever call establishment for emergency is interrupted between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete) by O-DU error detection (Call acceptance condition of CU/DU is not met). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ESTACALL.IncompEmergencyOduErrDetect | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.15.31 Discarded paging records + +### A.15.31.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------| +| Measurement Name | PAG.DiscardedNbrCnInitiated | +| Description | Refer to 3GPP TS 28.552 [8] clause 5.1.1.27.4 | +| Collection Method | Refer to 3GPP TS 28.552 [8] clause 5.1.1.27.4 | +| Condition | Refer to 3GPP TS 28.552 [8] clause 5.1.1.27.4 | +| Measurement Result | Refer to 3GPP TS 28.552 [8] clause 5.1.1.27.4 | +| Measurement Type | Refer to 3GPP TS 28.552 [8] clause 5.1.1.27.4 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [8] clause 5.1.1.27.4 | +| Switching Technology | Refer to 3GPP TS 28.552 [8] clause 5.1.1.27.4 | +| Generation | Refer to 3GPP TS 28.552 [8] clause 5.1.1.27.4 | +| Purpose | Refer to 3GPP TS 28.552 [8] clause 5.1.1.27.4 | + +## A.16 Monitoring of PDU session connection for SA + +### A.16.1 Accepted PDU Session Resource Configuration + +#### A.16.1.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDUSESSION.AcceptConfig | +| Description | This counter provides the number of the accepted PDU session resource configuration per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever gNB received the following message per CU count group.<br>Note: multiple 5QIs can be set per PDU session, each 5QI is counted per QoS flow.<br><br><ul style="list-style-type: none"> <li>- "NG-AP: Initial Context Setup Request" is received</li> <li>- "NG-AP: PDU Session Resource Setup Request"</li> <li>- "NG-AP: PDU Session Resource Modify Request"</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.PDUSESSION.AcceptConfig. <i>Cucountgroup</i> where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.16.2 Completed PDU Session Resource Configuration + +#### A.16.2.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDUSESSION.CompConfig | +| Description | This counter provides the number of the completed PDU session resource configuration per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever gNB transmitted the following message per CU count group.<br>Note: multiple 5QIs can be set per PDU session, each 5QI is counted per QoS flow.<br><br><ul style="list-style-type: none"> <li>- "NG-AP: Initial Context Setup Response"</li> <li>- "NG-AP: PDU Session Resource Setup Response"</li> <li>- "NG-AP: PDU Session Resource Modify Response"</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.PDUSESSION.CompConfig. <i>Cucountgroup</i> where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.16.3 Interrupted PDU Session Resource configuration by Protocol Error + +### A.16.3.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDUSESSION.InterruptConfigProcolErr | +| Description | This counter provides the number of the PDU session resource configuration interrupted by protocol error per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is incremented by 1 whenever the PDU session resource configuration interrupted in the following interval by protocol error per CU count group.</p> <p>Note: multiple 5QIs can be set per PDU session, each 5QI is counted per QoS flow.</p> <ul style="list-style-type: none"> <li>- between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete)</li> <li>- between Xn-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w Xn)</li> <li>- between NG-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w/o Xn)</li> <li>- between NG-AP: Handover Request to NG-AP: Handover Notify (Inter RAT HO to NR)</li> <li>- between NG-AP: PDU Session Resource Setup Request to NG-AP: PDU Session Resource Setup Response (PDU Session Establishment)</li> <li>- between NG-AP: PDU Session Resource Modify Request to NG-AP: PDU Session Resource Modify Response (PDU Session Modification)</li> <li>- between NG-AP: PDU Session Resource Release Request to NG-AP: PDU Session Resource Release Response (PDU Session Release)</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.PDUSESSION.InterruptConfigProcolErr.Cucountgroup where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.16.4 Interrupted PDU Session Resource configuration by O-DU Error Detection + +### A.16.4.1 Performance Counter Table + +| | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDUSESSION.InterruptConfigOduErrDetect | +| Description | This counter provides the number of the PDU session resource configuration interrupted by O-DU error detection per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is incremented by 1 whenever the PDU session resource configuration interrupted in the following interval by O-DU error detection per CU count group.</p> <p>Note: multiple 5QIs can be set per PDU session, each 5QI is counted per QoS flow.</p> | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>- between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete)</li> <li>- between Xn-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w Xn)</li> <li>- between NG-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w/o Xn)</li> <li>- between NG-AP: Handover Request to NG-AP: Handover Notify (Inter RAT HO to NR)</li> <li>- between NG-AP: PDU Session Resource Setup Request to NG-AP: PDU Session Resource Setup Response (PDU Session Establishment)</li> <li>- between NG-AP: PDU Session Resource Modify Request to NG-AP: PDU Session Resource Modify Response (PDU Session Modification)</li> <li>- between NG-AP: PDU Session Resource Release Request to NG-AP: PDU Session Resource Release Response (PDU Session Release)</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.PDUSESSION.InterruptConfigOduErrDetect.Cucountgroup where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +3 + +## A.16.5 Interrupted PDU Session Resource configuration by O-CU internal error + +4 + +### A.16.5.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDUSESSION.InterruptConfigOcuInterErr | +| Description | This counter provides the number of the PDU session resource configuration interrupted by O-CU internal error per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is incremented by 1 whenever the PDU session resource configuration interrupted in the following interval by O-CU internal error per CU count group.</p> <p>Note: multiple 5QIs can be set per PDU session, each 5QI is counted per QoS flow.</p> <ul style="list-style-type: none"> <li>- between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete)</li> <li>- between Xn-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w Xn)</li> <li>- between NG-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w/o Xn)</li> <li>- between NG-AP: Handover Request to NG-AP: Handover Notify (Inter RAT HO to NR)</li> <li>- between NG-AP: PDU Session Resource Setup Request to NG-AP: PDU Session Resource Setup Response (PDU Session Establishment)</li> <li>- between NG-AP: PDU Session Resource Modify Request to NG-AP: PDU Session Resource Modify Response (PDU Session Modification)</li> </ul> | + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------| +| | - between NG-AP: PDU Session Resource Release Request to NG-AP: PDU Session Resource Release Response (PDU Session Release) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.PDUSESSION.InterruptConfigOcuInterErr. <i>Cucountgroup</i> where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.16.6 Accepted PDU Session Resource Configuration for emergency and high priority access + +### A.16.6.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDUSESSION.AcceptConfigEmergencyHighPriAccess | +| Description | This counter provides the number of the accepted PDU session resource configuration for emergency and high priority access per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever gNB received the following message after received RRC: RRC Setup Request (Establishment Cause: emergency or high priority access) per CU count group.<br>Note: multiple 5QIs can be set per PDU session, each 5QI is counted per QoS flow.<br>- received NG-AP: Initial Context Setup Request<br>- received NG-AP: PDU Session Resource Setup Request<br>- received NG-AP: PDU Session Resource Modify Request | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.PDUSESSION.AcceptConfigEmergencyHighPriAccess. <i>Cucountgroup</i> where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.16.7 Completed PDU Session Resource Configuration for emergency and high priority access + +### A.16.7.1 Performance Counter Table + +| | | +|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDUSESSION.CompConfigEmergencyHighPriAccess | +| Description | This counter provides the number of the completed PDU session resource configuration for emergency and high priority access per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever gNB transmitted the following message after received RRC: RRC Setup Request (Establishment Cause: emergency or high priority access) per CU count group. | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Note: multiple 5QIs can be set per PDU session, each 5QI is counted per QoS flow.<br>- send NG-AP: Initial Context Setup Response<br>- send NG-AP: PDU Session Resource Setup Response<br>- send NG-AP: PDU Session Resource Modify Response | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.PDUSESSION.CompConfigEmergencyHighPriAccess.Cucountgroup where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +3 + +## A.16.8 Interrupted PDU Session Resource configuration for emergency and high priority access by Protocol Error + +4 + +### A.16.8.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDUSESSION.InterruptConfigProcolErrEmergencyHighPriAccess | +| Description | This counter provides the number of the PDU session resource configuration for emergency and high priority access interrupted by protocol error per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the PDU session resource configuration for emergency and high priority access interrupted in the following interval by protocol error per CU count group.<br>Note: multiple 5QIs can be set per PDU session, each 5QI is counted per QoS flow.<br>- between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete)<br>- between Xn-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w Xn)<br>- between NG-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w/o Xn)<br>- between NG-AP: Handover Request to NG-AP: Handover Notify (Inter RAT HO to NR)<br>- between NG-AP: PDU Session Resource Setup Request to NG-AP: PDU Session Resource Setup Response (PDU Session Establishment)<br>- between NG-AP: PDU Session Resource Modify Request to NG-AP: PDU Session Resource Modify Response (PDU Session Modification)<br>- between NG-AP: PDU Session Resource Release Request to NG-AP: PDU Session Resource Release Response (PDU Session Release) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.PDUSESSION.InterruptConfigProcolErrEmergencyHighPriAccess.Cucountgroup where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.16.9 Interrupted PDU Session Resource configuration for emergency and high priority access by O-DU Error Detection + +### A.16.9.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.PDUSESSION.InterruptConfigOduErrDetectEmergencyHighPriAccess | +| Description | This counter provides the number of the PDU session resource configuration for emergency and high priority access interrupted by O-DU error detection per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the PDU session resource configuration for emergency and high priority access interrupted in the following interval by O-DU error detection per CU count group.<br>Note: multiple 5QIs can be set per PDU session, each 5QI is counted per QoS flow. <ul style="list-style-type: none"> <li>- between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete)</li> <li>- between Xn-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w Xn)</li> <li>- between NG-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w/o Xn)</li> <li>- between NG-AP: Handover Request to NG-AP: Handover Notify (Inter RAT HO to NR)</li> <li>- between NG-AP: PDU Session Resource Setup Request to NG-AP: PDU Session Resource Setup Response (PDU Session Establishment)</li> <li>- between NG-AP: PDU Session Resource Modify Request to NG-AP: PDU Session Resource Modify Response (PDU Session Modification)</li> <li>- between NG-AP: PDU Session Resource Release Request to NG-AP: PDU Session Resource Release Response (PDU Session Release)</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.PDUSESSION.InterruptConfigOduErrDetectEmergencyHighPriAccess. <i>Cucountgroup</i> where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.16.10 Interrupted PDU Session Resource configuration for emergency and high priority access by O-CU internal Error + +### A.16.10.1 Performance Counter Table + +| | | +|------------------|----------------------------------------------------------------| +| Measurement Name | OR.PDUSESSION.InterruptConfigOcuInterErrEmergencyHighPriAccess | +|------------------|----------------------------------------------------------------| + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Description | This counter provides the number of the PDU session resource configuration for emergency and high priority access interrupted by O-CU internal error per CU count group. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is incremented by 1 whenever the PDU session resource configuration for emergency and high priority access interrupted in the following interval by O-CU internal error per CU count group.</p> <p>Note: multiple 5QIs can be set per PDU session, each 5QI is counted per QoS flow.</p> <ul style="list-style-type: none"> <li>- between RRC: RRC Setup Request (or RRC: RRC Resume Request) to NG-AP: Initial Context Setup Response (or RRC: RRC Resume Complete)</li> <li>- between Xn-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w Xn)</li> <li>- between NG-AP: Handover Request to NG-AP: Path Switch Acknowledge (Inter gNB-CU HO w/o Xn)</li> <li>- between NG-AP: Handover Request to NG-AP: Handover Notify (Inter RAT HO to NR)</li> <li>- between NG-AP: PDU Session Resource Setup Request to NG-AP: PDU Session Resource Setup Response (PDU Session Establishment)</li> <li>- between NG-AP: PDU Session Resource Modify Request to NG-AP: PDU Session Resource Modify Response (PDU Session Modification)</li> <li>- between NG-AP: PDU Session Resource Release Request to NG-AP: PDU Session Resource Release Response (PDU Session Release)</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.PDUSESSION.InterruptConfigOcuInterErrEmergencyHighPriAccess.Cucountgroup where <i>Cucountgroup</i> identifies an instance of CuCountGroup IOC. | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.17 Monitoring of mobility for SA + +### A.17.1 Accepted Handover + +#### A.17.1.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.AcceptHo | +| Description | This counter provides the number of the accepted Intra RAT handover. | +| Collection Method | CC (Cumulative Counter) | +| Condition | <p>Measurement subcounter is incremented by 1 whenever source gNB decides to perform Intra RAT HO procedure by the received (transmitted) following messages:</p> <ul style="list-style-type: none"> <li>- Intra-Cell HO: transmitted "RRC: RRC Reconfiguration"</li> <li>- HO procedure other than those above: received "RRC: Measurement report"</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.AcceptHo | +| Measurement Object Class | NRCelICU | + +| | | +|----------------------|--------------------------------------------------| +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.17.2 Completed Handover + +### A.17.2.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.CompHo | +| Description | This counter provides the number of the completed Intra RAT handover. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever source gNB detects successful Intra RAT handover procedure triggered by source gNB by the received following messages: <ul style="list-style-type: none"> <li>- Intra-gNB HO: received "RRC: RRC Reconfiguration Complete"</li> <li>- HO procedure other than those above: received "XnAP:UE CONTEXT RELEASE" from the target gNB at Xn HO or "NGAP:UE CONTEXT RELEASE COMMAND" from AMF at NG HO</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.CompHo | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.17.3 Accepted Inter RAT Handover to LTE + +### A.17.3.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.AcceptHotoLte | +| Description | This counter provides the number of the accepted Inter RAT Handover to LTE. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever source gNB decides to perform Inter RAT HO to LTE procedure by the received following messages: <ul style="list-style-type: none"> <li>- received RRC: Measurement report (Inter RAT HO to LTE)</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.AcceptHotoLte | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.17.4 Completed Inter RAT Handover to LTE + +### A.17.4.1 Performance Counter Table + +| | | +|-------------------|------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.CompHotoLte | +| Description | This counter provides the number of the completed Inter RAT Handover to LTE. | +| Collection Method | CC (Cumulative Counter) | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | Measurement subcounter is incremented by 1 whenever source gNB detects successful handover procedure triggered by source gNB by the received following messages:<br>- received NG-AP: UE Context Release Command (Inter RAT HO to LTE) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.CompHotoLte | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.17.5 Accepted EPS Fallback + +### 3 A.17.5.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.AcceptEpsFallback | +| Description | This counter provides the number of the accepted EPS Fallback. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PCell decides to perform EPS Fallback procedure by the received following messages:<br>- received NG-AP: PDU Session Resource Modify Request (EPS Fallback) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.AcceptEpsFallback | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## 5 A.17.6 Completed EPS Fallback + +### 6 A.17.6.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.CompEpsFallback | +| Description | This counter provides the number of the completed EPS Fallback. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PCell detects successful EPS Fallback procedure triggered by the received following messages:<br>- received NG-AP: UE Context Release Command (EPS Fallback) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.CompEpsFallback | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +7 + +## A.17.7 Normal interrupted EPS Fallback + +### A.17.7.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.NormalInterruptedEpsFallback | +| Description | This counter provides the number of the completed EPS Fallback. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PCell detects interrupted EPS Fallback procedure triggered by the received following messages:<br>- received NG-AP: UE Context Release Command (Cause:Deregister) during EPS Fallback procedure | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.NormalInterruptedEpsFallback | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.17.8 Accepted Handover during Voice call + +### A.17.8.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.AcceptHoVoice | +| Description | This counter provides the number of the accepted Intra RAT handover during voice call. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever source gNB decides to perform Intra RAT HO procedure by the received (transmitted) following messages during voice call:<br>- transmitted RRC: RRC Reconfiguration (Intra-cell HO)<br>- HO procedure other than those above: received RRC: Measurement report | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.AcceptHoVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.17.9 Completed Handover during Voice call + +### A.17.9.1 Performance Counter Table + +| | | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.CompHoVoice | +| Description | This counter provides the number of the completed Intra RAT handover during voice call. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever source gNB detects successful Intra RAT handover procedure triggered by source gNB by the received following messages during voice call:<br>- received RRC: RRC Reconfiguration Complete (Intra gNB-CU Inter gNB-DU HO, Intra gNB-DU Inter-cell HO)<br>- HO procedure other than those above: received Xn-AP: UE | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------| +| | CONTEXT RELEASE (Inter gNB-CU HO w/ Xn), NG-AP: UE CONTEXT RELEASE COMMAND (Inter gNB-CU HO w/o Xn) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.CompHoVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.17.10 Accepted Inter RAT Handover to LTE during Voice call + +### A.17.10.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.AcceptHotoLteVoice | +| Description | This counter provides the number of the accepted Inter RAT handover to LTE during voice call. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever source gNB decides to perform Inter RAT HO to LTE procedure by the received following messages during voice call:<br>- received RRC: Measurement report that triggers Inter RAT HO to LTE | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.AcceptHotoLteVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.17.11 Completed Inter RAT Handover to LTE during Voice call + +### A.17.11.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MOBILITY.CompHotoLteVoice | +| Description | This counter provides the number of the completed Inter RAT handover during voice call. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever source gNB detects successful Inter RAT handover procedure triggered by source gNB by the received following messages during voice call:<br>- received NG-AP: UE CONTEXT RELEASE COMMAND from the AMF at Inter RAT HO to LTE | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.MOBILITY.CompHotoLteVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.18 Monitoring of RRC re-establishment for SA + +### A.18.1 Number of initial RRC re-establishment requests when UE context can be retrieved + +#### A.18.1.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.IniReqUecontext | +| Description | This counter provides the number of the received RRC: RRC Reestablishment Request messages via F1-C which is in the first time for each ReestabUE-Identity when UE context can be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reestablishment Request message is received via F1-C when UE context can be retrieved, if RRC: RRC Reestablishment Request of the same ReestabUE-Identity is not received for a certain period of time from the reception timing. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.IniReqUecontext | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.18.2 Number of RRC re-establishment request completions for initial RRC re-establishment requests when UE context can be retrieved + +#### A.18.2.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.IniReqCompUecontext | +| Description | This counter provides the number of the received RRC: RRC Reconfiguration Complete messages via F1-C which corresponds to the initial RRC: RRC Reestablishment Request when UE context can be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reconfiguration Complete message which corresponds to the initial RRC: RRC Reestablishment Request is received via F1-C when UE context can be retrieved. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.IniReqCompUecontext | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.18.3 Number of retransmission RRC re-establishment requests when UE context can be retrieved + +### A.18.3.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.RetaransReqUecontext | +| Description | This counter provides the number of the received RRC: RRC Reestablishment Request messages via F1-C which is the retransmission for each ReestabUE-Identity when UE context can be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reestablishment Request message is received via F1-C when UE context can be retrieved, if RRC: RRC Reestablishment Request message of the same ReestabUE-Identity is received for a certain period of time from the reception timing. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.RetaransReqUecontext | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.18.4 Number of RRC re-establishment request completions for retransmission RRC re-establishment request when UE context can be retrieved + +### A.18.4.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.RetaransReqCompUecontext | +| Description | This counter provides the number of the received RRC: RRC Reconfiguration Complete messages via F1-C which corresponds to the retransmission RRC: RRC Reestablishment Request when UE context can be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reconfiguration Complete message which corresponds to the retransmission RRC: RRC Reestablishment Request is received via F1-C when UE context can be retrieved. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.RetaransReqCompUecontext | +| Measurement Object Class | NRCelICUs | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.18.5 Number of initial RRC re-establishment requests when UE context cannot be retrieved + +### A.18.5.1 Performance Counter Table + +| | | +|------------------|-----------------------------| +| Measurement Name | OR.REEST.IniReqNotUecontext | +|------------------|-----------------------------| + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Description | This counter provides the number of the received RRC: RRC Reestablishment Request messages via F1-C which is in the first time for each ReestabUE-Identity when UE context cannot be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reestablishment Request message is received via F1-C when UE context cannot be retrieved, if RRC: RRC Reestablishment Request of the same ReestabUE-Identity is not received for a certain period of time from the reception timing. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.IniReqNotUecontext | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.18.6 Number of RRC re-establishment request completions for initial RRC re-establishment requests when UE context cannot be retrieved + +### A.18.6.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.IniReqCompNotUecontext | +| Description | This counter provides the number of the received RRC: RRC Reconfiguration Complete messages via F1-C which corresponds to the initial RRC: RRC Reestablishment Request when UE context cannot be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Setup Complete message which corresponds to the initial RRC: RRC Reestablishment Request is received via F1-C when UE context cannot be retrieved. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.IniReqCompNotUecontext | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.18.7 Number of retransmission RRC re-establishment requests when UE context cannot be retrieved + +### A.18.7.1 Performance Counter Table + +| | | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.RetReqNotUecontext | +| Description | This counter provides the number of the received RRC: RRC Reestablishment Request messages via F1-C which is the retransmission for each ReestabUE-Identity when UE context cannot be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reestablishment Request message is received via F1-C when UE context cannot be retrieved, if RRC: RRC Reestablishment Request message of the same ReestabUE-Identity is received for a certain period of time from the reception timing. | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.RetransReqNotUecontext | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +3 + +4 + +## A.18.8 Number of RRC re-establishment request completions for retransmission RRC re-establishment requests when UE context cannot be retrieved + +5 + +### A.18.8.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.RetReqCompNotUecontext | +| Description | This counter provides the number of the received RRC: RRC Reconfiguration Complete messages via F1-C which corresponds to the retransmission RRC: RRC Reestablishment Request when UE context cannot be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reconfiguration Complete message which corresponds to the retransmission RRC: RRC Reestablishment Request is received via F1-C when UE context cannot be retrieved. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.RetransReqCompNotUecontext | +| Measurement Object Class | NRCelICUs | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +6 + +7 + +8 + +## A.18.9 Number of initial RRC re-establishment requests during Voice call when UE context can be retrieved + +9 + +### A.18.9.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.IniReqUecontextVoice | +| Description | This counter provides the number of the received RRC: RRC Reestablishment Request messages via F1-C which is in the first time for each ReestabUE-Identity during voice call when UE context can be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reestablishment Request message is received via F1-C during voice call when UE context can be retrieved, if RRC: RRC Reestablishment Request of the same ReestabUE-Identity is not received for a certain period of time from the reception timing. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.IniReqUecontextVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | + +| | | +|---------|--------------------------------------------------| +| Purpose | Network Operator's Traffic Engineering Community | +|---------|--------------------------------------------------| + +## A.18.10 Number of RRC re-establishment request completions for initial RRC re-establishment requests during Voice call when UE context can be retrieved + +### A.18.10.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.IniReqCompUecontextVoice | +| Description | This counter provides the number of the received RRC: RRC Reconfiguration Complete messages via F1-C which corresponds to the initial RRC: RRC Reestablishment Request during voice call when UE context can be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reconfiguration Complete message which corresponds to the initial RRC: RRC Reestablishment Request is received via F1-C during voice call when UE context can be retrieved. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.IniReqCompUecontextVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.18.11 Number of retransmission RRC re-establishment requests during Voice call when UE context can be retrieved + +### A.18.11.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.RetaransReqUecontextVoice | +| Description | This counter provides the number of the received RRC: RRC Reestablishment Request messages via F1-C which is the retransmission for each ReestabUE-Identity during voice call when UE context can be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reestablishment Request message is received via F1-C during voice call when UE context can be retrieved, if RRC: RRC Reestablishment Request message of the same ReestabUE-Identity is received for a certain period of time from the reception timing. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.RetaransReqUecontextVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.18.12 Number of RRC re-establishment request completions for retransmission RRC re-establishment request during Voice call when UE context can be retrieved + +### A.18.12.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.REEST.RetransReqCompUecontextVoice | +| Description | This counter provides the number of the received RRC: RRC Reconfiguration Complete messages via F1-C which corresponds to the retransmission RRC: RRC Reestablishment Request during voice call when UE context can be retrieved. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever RRC: RRC Reconfiguration Complete message which corresponds to the retransmission RRC: RRC Reestablishment Request is received via F1-C during voice call when UE context can be retrieved. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.REEST.RetransReqCompUecontextVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.19 Monitoring of connection status for SA + +### A.19.1 Normally Released Calls + +#### A.19.1.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CONNECTSTATUS.NormalRelCalls | +| Description | This counter provides the number of the normally released calls. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the normally released calls. Normal released calls is as follows: <ul style="list-style-type: none"> <li>- received NG-AP: UE Context Release Command (Cause: Normal release or Deregister)</li> <li>- the expiry of a UE inactivity timer, the gNB suspend the RRC connection</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CONNECTSTATUS.NormalRelCalls | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.19.2 Abnormally Released Calls + +#### A.19.2.1 Performance Counter Table + +| | | +|-------------------|--------------------------------------------------------------------| +| Measurement Name | OR.CONNECTSTATUS.AbnormalRelCalls | +| Description | This counter provides the number of the abnormally released calls. | +| Collection Method | CC (Cumulative Counter) | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | Measurement subcounter is incremented by the number of the abnormally released calls.<br>- Trigger timing: when gNB release the UE Context except for the Normally Released calls (A.19.1) and Another Cell HO UE Contexts (A.19.3). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CONNECTSTATUS.AbnormalRelCalls | +| Measurement Object Class | NRCelICU NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.19.3 Another Cell HO UE Contexts + +### 3 A.19.3.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CONNECTSTATUS.AnotherCellHoUes | +| Description | This counter provides the number of the UE Contexts which has transferred to another cell. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UE Contexts which has transferred to another cell. Another Cell released call is as follows:<br>- received Xn-AP: UE Context Release (Inter gNB-CU HO w/ Xn, RRC Connection Re-establishment (Inter gNB-CU))<br>- received NG-AP: UE Context Release Command (Inter gNB-CU HO w/o Xn, Inter-RAT HO to LTE, EPS fallback)<br>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter-cell))<br>- received F1-AP: UE Context Release Command (Intra gNB-CU Inter gNB-DU HO, RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU)) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CONNECTSTATUS.AnotherCellHoUes | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## 5 A.19.4 Normally Released Calls during voice call + +### 6 A.19.4.1 Performance Counter Table + +| | | +|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CONNECTSTATUS.NormalRelCallsVoice | +| Description | This counter provides the number of the normally released calls during voice call. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the normally released calls during voice call. Normal released calls are as follows:<br>- received NG-AP: UE Context Release Command (Cause: Normal release or Deregister) | + +| | | +|--------------------------|---------------------------------------------------------------------------| +| | - the expiry of a UE inactivity timer, the gNB suspend the RRC connection | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CONNECTSTATUS.NormalRelCallsVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.19.5 Abnormally Released Calls during voice call + +3 + +### A.19.5.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CONNECTSTATUS.AbnormalRelCallsVoice | +| Description | This counter provides the number of the abnormally released calls during voice call. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the abnormally released calls during voice call.<br>- Trigger timing: when gNB release the UE Context except for the Normally Released calls (A.19.4) and Another Cell HO UE contexts (A.19.6) during voice call. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CONNECTSTATUS.AbnormalRelCallsVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +5 + +## A.19.6 Another Cell HO UE Contexts during voice call + +6 + +### A.19.6.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CONNECTSTATUS.AnotherCellHoUesVoice | +| Description | This counter provides the number of the UE Contexts which has transferred to another cell during voice call. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UE Contexts which has transferred to another cell during voice call. Another Cell released calls are as follows:<br>- received Xn-AP: UE Context Release (Inter gNB-CU HO w/ Xn, RRC Connection Re-establishment (Inter gNB-CU))<br>- received NG-AP: UE Context Release Command (Inter gNB-CU HO w/o Xn, Inter-RAT HO to LTE, EPS fallback)<br>- received RRC: RRC Reconfiguration Complete (Intra gNB-DU Inter-cell HO, RRC Connection Re-establishment (Intra gNB-DU Inter-cell))<br>- received F1-AP: UE Context Release Command (Intra gNB-CU Inter gNB-DU HO, RRC Connection Re-establishment (Intra gNB-CU Inter gNB-DU)) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CONNECTSTATUS.AnotherCellHoUesVoice | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | + +| | | +|------------|--------------------------------------------------| +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20 Monitoring of procedure for NR-DC + +### A.20.1 Number of S-NG-RAN Node Addition procedure attempted for each Cell + +#### A.20.1.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnAddAttemptCell | +| Description | This counter provides the number of the transmitted Xn-AP: S-NODE ADDITION REQUEST ACKNOWLEDGE message. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever Xn-AP: S-NODE ADDITION REQUEST ACKNOWLEDGE message is transmitted as PSCell. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnAddAttemptCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.20.2 Number of S-NG-RAN Node Addition procedure successfully for each Cell + +#### A.20.2.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnAddSuccessCell | +| Description | This counter provides the number of the completed S-NG-RAN Node addition Procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever S-NG-RAN Node addition procedure is completed as PSCell (i.e. Xn-AP: S-NODE RECONFIGURATION COMPLETE message (SN addition complete) is received and RACH processing with UE Context is completed). | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnAddSuccessCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.20.3 Number of S-NG-RAN Node Addition procedure attempted for each neighbour gNB + +#### A.20.3.1 Performance Counter Table + +| | | +|------------------|-------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnAddAttemptNeiGnb | +|------------------|-------------------------------------| + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Description | This counter provides the number of the transmitted Xn-AP: S-NODE ADDITION REQUEST ACKNOWLEDGE messages.<br>This counter is split into subcounters per neighbour gNB. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Xn-AP: S-NODE ADDITION REQUEST ACKNOWLEDGE message is transmitted when the gNB configured by the message is group of subcounter. <i>neighbourNB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnAddAttemptNeiGnb. <i>neighbourNB</i> where <i>neighbourNB</i> is neighbour gNB index:<br><br>0: #0<br><br>1: #1<br><br>...<br>63: #63 | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20.4 Number of S-NG-RAN Node Addition procedure successfully for each neighbour gNB + +### A.20.4.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnAddSuccessNeiGnb | +| Description | This counter provides the number of the completed S-NG-RAN Node addition Procedure.<br>This counter is split into subcounters per neighbour gNB. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is incremented by 1 whenever S-NG-RAN Node addition procedure is completed (i.e. Xn-AP: S-NODE RECONFIGURATION COMPLETE message (SN addition complete) is received and RACH processing with UE Context is completed) when the gNB configured by the message is group of subcounter. <i>neighbourNB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnAddSuccessNeiGnb. <i>neighbourNB</i> where <i>neighbourNB</i> is neighbour gNB index:<br><br>0: #0<br><br>1: #1<br><br>...<br>63: #63 | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20.5 Number of S-NG-RAN Node modification procedure attempted for each Cell + +### A.20.5.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnModAttemptCell | +| Description | This counter provides the number of the received Xn-AP: S-NODE MODIFICATION REQUEST messages or transmitted Xn-AP: S-NODE MODIFICATION REQUIRED messages. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Xn-AP: S-NODE MODIFICATION REQUEST message is received or Xn-AP: S-NODE MODIFICATION REQUIRED message is transmitted as PSCell. Double counting is not performed if the procedure is changed to the MN initiated SN Modification procedure after transmitted Xn-AP: S-NODE MODIFICATION REQUIRED message (e.g. Measurement gap Coordination (SN initiated)).<br><br>This subcounter will not be incremented if received Xn-AP: S-NODE MODIFICATION REQUEST message which True is set for SCG Configuration Query IE. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnModAttemptCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20.6 Number of S-NG-RAN Node modification procedure successfully for each Cell + +### A.20.6.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnModSuccessCell | +| Description | This counter provides the number of the completed S-NG-RAN Node modification Procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever SN Modification procedure is completed as PSCell (i.e. Xn-AP: S-NODE RECONFIGURATION COMPLETE message (SN modification complete) is received or Xn-AP: S-NODE MODIFICATION CONFIRM is received and RACH processing with UE Context is completed) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnModSuccessCell | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20.7 Number of S-NG-RAN Node modification procedure attempted for each neighbour gNB + +### A.20.7.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnModAttemptNeiGnb | +| Description | This counter provides the number of the received Xn-AP: S-NODE MODIFICATION REQUEST messages or transmitted Xn-AP: S-NODE MODIFICATION REQUIRED messages.<br>This counter is split into subcounters per neighbour gNB. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Xn-AP: S-NODE MODIFICATION REQUEST message is received or Xn-AP: S-NODE MODIFICATION REQUIRED message is transmitted, when the gNB configured by the message is group of subcounter. <i>neighbourgNB</i> .<br>Double counting is not performed if the procedure is changed to the MN initiated SN Modification procedure after transmitted Xn-AP: S-NODE MODIFICATION REQUIRED message (e.g. Measurement gap Coordination (SN initiated)).<br><br>This subcounter will not be incremented if received Xn-AP: S-NODE MODIFICATION REQUEST message which True is set for SCG Configuration Query IE. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnModAttemptNeiGnb. <i>neighbourgNB</i> where <i>neighbourgNB</i> is neighbour gNB index:<br><br>0: #0<br><br>1: #1<br><br>...<br><br>63: #63 | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20.8 Number of S-NG-RAN Node modification procedure successfully for each neighbour gNB + +### A.20.8.1 Performance Counter Table + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnModSuccessNeiGnb | +| Description | This counter provides the number of the completed S-NG-RAN Node modification Procedure.<br>This counter is split into subcounters per neighbour gNB. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever SN Modification procedure is completed (i.e. Xn-AP: S-NODE RECONFIGURATION COMPLETE message (SN modification complete) is received or Xn-AP: S-NODE MODIFICATION CONFIRM is received and RACH processing with UE Context is completed) when the gNB configured by the message is group of subcounter. <i>neighbourgNB</i> . | +| Measurement Result | Integer number (U32) | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Type | OR.NRDCPROCEDURE.SnModSuccessNeiGnb. <i>neighbourNB</i> where <i>neighbourNB</i> is neighbour gNB index:<br><br>0: #0<br><br>1: #1<br><br>...<br><br>63: #63 | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20.9 Number of S-NG-RAN Node Release procedure attempted for each Cell + +### A.20.9.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnRelAttemptCell | +| Description | This counter provides the number of the received Xn-AP: S-NODE RELEASE REQUIRED messages or transmitted Xn-AP: S-NODE RELEASE REQUEST messages. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Xn-AP: S-NODE RELEASE REQUIRED message is received or Xn-AP: S-NODE RELEASE REQUEST message is transmitted as PSCell. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnRelAttemptCell | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20.10 Number of S-NG-RAN Node Release procedure successfully for each Cell + +### A.20.10.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnRelSuccessCell | +| Description | This counter provides the number of the completed S-NG-RAN Node Release Procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever SN Release procedure is completed as PSCell (i.e. Xn-AP: UE CONTEXT RELEASE message is transmitted) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnRelSuccessCell | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20.11 Number of S-NG-RAN Node Release procedure attempted for each neighbour gNB + +### A.20.11.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnRelAttemptNeiGnb | +| Description | This counter provides the number of the received Xn-AP: S-NODE RELEASE REQUIRED messages or transmitted Xn-AP: S-NODE RELEASE REQUEST messages.<br>This counter is split into subcounters per neighbour gNB. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Xn-AP: S-NODE RELEASE REQUIRED message is received or Xn-AP: S-NODE RELEASE REQUEST message is transmitted, when the gNB configured by the message is group of subcounter. <i>neighbourgNB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnRelAttemptNeiGnb. <i>neighbourgNB</i> where <i>neighbourgNB</i> is neighbour gNB index:<br><br>0: #0<br><br>1: #1<br><br>...<br><br>63: #63 | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20.12 Number of S-NG-RAN Node Release procedure successfully for each neighbour gNB + +### A.20.12.1 Performance Counter Table + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.SnRelSuccessNeiGnb | +| Description | This counter provides the number of the completed S-NG-RAN Node Release Procedure.<br>This counter is split into subcounters per neighbour gNB. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever SN Release procedure is completed (i.e. Xn-AP: UE CONTEXT RELEASE message is transmitted) | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.SnRelSuccessNeiGnb. <i>neighbourgNB</i> where <i>neighbourgNB</i> is neighbour gNB index:<br><br>0: #0<br><br>1: #1<br><br>...<br><br>63: #63 | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.20.13 Number of SCGFailureInformation received + +### A.20.13.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.NRDCPROCEDURE.NumSCGFailInfoRec | +| Description | This counter provides the number of SCGFailureInformation received. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RRC: SCG Failure Information message is received. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.NRDCPROCEDURE.NumFailInfoRec | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.21 Monitoring of CA for SA + +### A.21.1 Number of SCell Addition procedure attempted + +#### A.21.1.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.SACAPROCEDURE.ScclAddAttempt | +| Description | This counter provides the number of the attempted SCell addition procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Special Cell decides to perform SCell addition procedure by the following trigger. <ul style="list-style-type: none"> <li>received RRC: Measurement report for SCell addition.</li> <li>SCell addition triggered internal the gNB other than above trigger.</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.SACAPROCEDURE.ScclAddAttempt | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.21.2 Number of SCell Addition procedure successfully + +#### A.21.2.1 Performance Counter Table + +| | | +|------------------|------------------------------------------------------------------| +| Measurement Name | OR.SACAPROCEDURE.ScclAddSuccess | +| Description | This counter provides the number of the completed SCell addition | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Special Cell detects successful SCell addition procedure by the received following messages.<br>– received RRC: RRC Reconfiguration Complete for SCell addition. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.SACAPROCEDURE.ScclAddSuccess | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.21.3 Number of SCell Change procedure attempted + +### 3 A.21.3.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.SACAPROCEDURE.ScclChangeAttempt | +| Description | This counter provides the number of the attempted SCell change procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Special Cell decides to perform SCell change procedure by the following trigger.<br>– received RRC: Measurement report for SCell change.<br>– SCell change triggered internal the gNB other than above trigger. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.SACAPROCEDURE.ScclChangeAttempt | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## 5 A.21.4 Number of SCell Change procedure successfully + +### 6 A.21.4.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.SACAPROCEDURE.ScclChangeSuccess | +| Description | This counter provides the number of the completed SCell change procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Special Cell detects successful SCell change procedure by the received following messages.<br>– received RRC: RRC Reconfiguration Complete for SCell change. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.SACAPROCEDURE.ScclChangeSuccess | +| Measurement Object Class | NRCellCU | +| Switching Technology | Packet Switched | + +| | | +|------------|--------------------------------------------------| +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.21.5 Number of SCell Deletion procedure attempted + +### A.21.5.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.SACAPROCEDURE.ScclDeletionAttempt | +| Description | This counter provides the number of the attempted SCell deletion procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Special Cell decides to perform SCell deletion procedure by the following trigger. <ul style="list-style-type: none"> <li>received RRC: Measurement report for SCell deletion.</li> <li>SCell deletion triggered internal the gNB other than above trigger.</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.SACAPROCEDURE.ScclDeletionAttempt | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.21.6 Number of SCell Deletion procedure successfully + +### A.21.6.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.SACAPROCEDURE.ScclDeletionSuccess | +| Description | This counter provides the number of the completed SCell deletion procedure. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever Special Cell detects successful SCell deletion procedure by the received following messages. <ul style="list-style-type: none"> <li>received RRC: RRC Reconfiguration Complete for SCell deletion.</li> </ul> | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.SACAPROCEDURE.ScclDeletionSuccess | +| Measurement Object Class | NRCelICU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## Revision History + +| Date | Revision | Author | Description | +|------------|----------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.03.25 | 03.00 | O-RAN-WG5 | Draft for voting | +| 2022.07.21 | 04.00 | O-RAN-WG5 | Updates to v03.00: <ul style="list-style-type: none"> <li>- Additional clarification on alignment with O-RAN O1 specification document</li> <li>- Editorial fixes</li> </ul> | +| 2023.03.08 | 05.00 | O-RAN-WG5 | Updates to v04.00: <ul style="list-style-type: none"> <li>- Updates to Performance counters in Annex A</li> <li>- Addition of information model of CuCountGroup</li> <li>- Editorial fixes</li> </ul> | +| 2023.07.06 | 06.00 | O-RAN-WG5 | Updates to v05.00: <ul style="list-style-type: none"> <li>- Editorial modification to align with ODR</li> <li>- Clarifications and corrections for PM counters in Annex A</li> </ul> | +| 2023.11.01 | 07.00 | O-RAN-WG5 | Updated to v06.00: <ul style="list-style-type: none"> <li>- Removed description of rpc: list-available-files</li> <li>- Added O-CU-CP QoS IM</li> <li>- Clarification on counters defined in A.10.1 to A.10.12, A.11.1 to A.11.8, A14.1 to A14.12, A.15.1 to A.15.20, A.16.3 to A.16.5, A.19.2 to A.19.3</li> <li>- Addition of new counters in A.1.11, A.1.12, A.3.3, A.3.4, A.11.9 to A.11.15, A.11.21 to A.11.31, A.16.6 to A.16.10, A.17.3 to A.17.11, A.18.9 to A.18.12, A.19.4 to A.19.6, A.20.1 to A.20.13, A.21.1 to A.21.6</li> <li>- Minor editorial changes</li> </ul> | \ No newline at end of file diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/065ffb6f6f72ea1204012cda1dbf5b5c_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/065ffb6f6f72ea1204012cda1dbf5b5c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0b2c9568e61b6c65f83c4ce3702e56bef8d10d62 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/065ffb6f6f72ea1204012cda1dbf5b5c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ec6ee54f17c588e7fd8dbe28a9d931ea746f7d6497506e94eb5b6838ee4d9fe0 +size 4137 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/0927fa56b72b1a36eb4d95414dfc28e7_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/0927fa56b72b1a36eb4d95414dfc28e7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..746afef5f6dd349d629c6bca5be79b7ecbb374fc --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/0927fa56b72b1a36eb4d95414dfc28e7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:691da161b4389fea821ef034f64fe93d4226c0a25d810d61a520061060414c94 +size 103736 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/10d7dcfe5c12d3516f426a3651401445_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/10d7dcfe5c12d3516f426a3651401445_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ff92b8fe3e70261df0503001efebcc37e686f921 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/10d7dcfe5c12d3516f426a3651401445_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c3f364b757fa002ad56113af4681a1f31f3d884820e7f662138234c5c59985ae +size 38663 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/3040f61099850ff4f7801b4b69a142c7_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/3040f61099850ff4f7801b4b69a142c7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7af539e5b75b1c6da298c10f80cef9fd54e5b11f --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/3040f61099850ff4f7801b4b69a142c7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:310b04051b9770d387fed1a9209c662cb768102ec5f92168b560dc02d255e75d +size 54483 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/3273e9ecbce230c236a8a62a8e849663_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/3273e9ecbce230c236a8a62a8e849663_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bd7b28ed59fae4a75f85ff235b832ead2762bf36 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/3273e9ecbce230c236a8a62a8e849663_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3291140cd6a3c36372c64079303ba92c386cc161cfa29dbb873766ec5afd88f6 +size 22135 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/33201ebc7872a74abf078c083697a6b9_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/33201ebc7872a74abf078c083697a6b9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..924f6c214be0dbfb862b120b50374d61e763e2c1 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/33201ebc7872a74abf078c083697a6b9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1a586bf45c9ea4c6240a194f2b8c7cad8b7524a7dbe9535366c4eb26c0fb5ac8 +size 189806 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/634e55b0032a3c5fed25f70e1d55cf02_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/634e55b0032a3c5fed25f70e1d55cf02_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c4e498a94d71478283288702663208072872ce58 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/634e55b0032a3c5fed25f70e1d55cf02_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:43b58ec9d3dfc9c3250260df79f20c7814b5ab6f5dddb18caf31c37147d34716 +size 54510 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/6e43e95601251e761b5354e5ae169daf_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/6e43e95601251e761b5354e5ae169daf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..06052ff498f01dc00538af3a34de656f2d448c4f --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/6e43e95601251e761b5354e5ae169daf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b096cf8af8781041924dfcaaa131f748732808134de68592a83a698b384341e6 +size 4029 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/7b55cea959bce23c4565284e6a7b6283_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/7b55cea959bce23c4565284e6a7b6283_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b171a8e06189e67b21ae67b316349c726e6606aa --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/7b55cea959bce23c4565284e6a7b6283_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3fee9b80b6bdd7ee00d270a6296e9fce146f450db9e20a3c980295a4b9cf69ed +size 94806 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/7d21b44a95b44c334a065c2d7b2c4004_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/7d21b44a95b44c334a065c2d7b2c4004_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2ed0b19f12338c520af9c09a02c96f9abf32d7e7 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/7d21b44a95b44c334a065c2d7b2c4004_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f48174292929c82f4d3d25e3f35a0599230c14a32e83982237677aba642b0d2a +size 4170 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/9875b0f0c5e94994a43b9024da538203_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/9875b0f0c5e94994a43b9024da538203_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..32fcc62a1906fdfd405021cd430e5f7252064569 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/9875b0f0c5e94994a43b9024da538203_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ea9fa408845f59443e17ee6e64965392f8d4b83b5093745c1bc91b29a59cc05 +size 21498 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/98f5e58f6d743b4c325f53747a793da5_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/98f5e58f6d743b4c325f53747a793da5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a48282fb7c4634d3f8b765fce162ea64a0cbfbdb --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/98f5e58f6d743b4c325f53747a793da5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:93da02eb02c9da98395692891ceb1e9adb6cfa7da3a93bd255668871a7a833a5 +size 74125 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/9f4b307d900659d1a3ef0a7186eb4a83_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/9f4b307d900659d1a3ef0a7186eb4a83_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..11fe14ad87a238d1ee9320f80255d7e9f6d97451 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/9f4b307d900659d1a3ef0a7186eb4a83_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7e2b30f7ab585e142d3c53daa2bcbd9eedc35ee94d4e224824079bf2e248e13a +size 4134 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/a260dd6adb7b11ee98f12a299ca876b2_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/a260dd6adb7b11ee98f12a299ca876b2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1f6f5abf0a149ce9ff643142bdcec3b1502be6c9 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/a260dd6adb7b11ee98f12a299ca876b2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6fcb648125126a9b825c6cdd4de6cd867ea0cf92b96c3ff1b65d6497e6488621 +size 175792 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/a662186f488ad1cde43011203483a607_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/a662186f488ad1cde43011203483a607_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0083bbcd477a440af246531da0d9ca834fcef69d --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/a662186f488ad1cde43011203483a607_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:031897db0b5eb2ce58429303a824c2474348172755ed5338c9b2971a7476ff61 +size 4029 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/af0347e352bb15c70674c799ad7f9ee0_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/af0347e352bb15c70674c799ad7f9ee0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3ff7602259185620215708f2a706254ff2e8e962 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/af0347e352bb15c70674c799ad7f9ee0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:11af9a7d5f0c4dbe63704ceedb40a0bdd25229ca9b4fd04b8d89a79f7a4b834d +size 153085 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/afb637064fc23d177a87d37b08c3678f_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/afb637064fc23d177a87d37b08c3678f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..af463d4d9159cf0b0e3396a92f4b95980db55243 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/afb637064fc23d177a87d37b08c3678f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d016d13e732a842886c0f188e826ff73e9bb437762e0d302918fe07c6a83af34 +size 162557 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/b049662c2cffb8ff53c8013d21fad304_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/b049662c2cffb8ff53c8013d21fad304_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..769cfecd1c8d2a8b87947db2f91fce3026f2dd86 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/b049662c2cffb8ff53c8013d21fad304_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:97eedd478efa2a71318049545930fcd6dc75b0a726431ed3b80fce4ff5ba15de +size 137369 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/b66ab6ef0e4f2cbd034f427ad9261041_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/b66ab6ef0e4f2cbd034f427ad9261041_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2b476013801f4e711ade49d0fae42f72b6802828 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/b66ab6ef0e4f2cbd034f427ad9261041_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b0c4bab16064079cdd77952167fabc61631267148196718f492e06b4930bf07 +size 137630 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/c3755c78c49568b39ea4cafe4a311066_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/c3755c78c49568b39ea4cafe4a311066_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9a06647395d6400ddf82f872b4a7721cc0dfd33f --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/c3755c78c49568b39ea4cafe4a311066_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:97052ad6e89b332a8ab85e14425a917959644c0c728ed32835a0e8e80a2f4ba8 +size 47691 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/c720b32051a7be1cab60363c909d0d1e_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/c720b32051a7be1cab60363c909d0d1e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7173b7e26eb68c794d70e781f898ca2313f04ccc --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/c720b32051a7be1cab60363c909d0d1e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:11806909f54c4efac69317bd0a650fde7fe6646ade1172cf081c2628e8fba6cb +size 44254 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/d0c7d10b7a41fa7d670542bf2b9e9ffb_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/d0c7d10b7a41fa7d670542bf2b9e9ffb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a366097ff31a4a9309bfd4ea737975717fc5c3dc --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/d0c7d10b7a41fa7d670542bf2b9e9ffb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:245cb5bacee5d5ee3e3c8d8eac790fe83c9540a07cc7fd86f5494744d40352ca +size 35164 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/d60b5c0c3ff7b33edb8ed179623e60c7_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/d60b5c0c3ff7b33edb8ed179623e60c7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a6aaac1ce328ded07e07555a3e5c935b6454f890 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/d60b5c0c3ff7b33edb8ed179623e60c7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2348ed297d173e612f540f6f3fa15900fe0ba652104755ae74d9114004ac1da3 +size 35472 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/e302684185b47169a4b530bcca918699_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/e302684185b47169a4b530bcca918699_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..04b0438918bd3a3d0f161bbcc883d6c13e58fa5a --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/e302684185b47169a4b530bcca918699_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:47129150e2ecaf8de3b16cbd985703f69bc18bb661b5cd6f0df829a610cd3175 +size 4134 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/f52a2ca8e18673298690274c44fdbe15_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/f52a2ca8e18673298690274c44fdbe15_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..20f59c8c3001ea45d6bb50cdbe474a0d421a0005 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/f52a2ca8e18673298690274c44fdbe15_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e5c6ae56b15ce6cf76eab760e2c16b5bacbafe179d8b85145357cb81bf90e02 +size 74312 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/fb5a0e58b6e405c4bc82b2d9d85275d4_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/fb5a0e58b6e405c4bc82b2d9d85275d4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7b635cbce0a176016a26a55fdd8c8263f51ef84 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/fb5a0e58b6e405c4bc82b2d9d85275d4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8af07c76f8bb0eb6f44a99baad844375e1dbae3f28542ecfd149fc7f3485db5a +size 3865 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/fdd184b6875e8ad70b43c4c5c120ff89_img.jpg b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/fdd184b6875e8ad70b43c4c5c120ff89_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bd617101732408806d40108bac5767d27ed8a940 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/fdd184b6875e8ad70b43c4c5c120ff89_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:636ec607a9818549f4ac69fa9a9352e784f5b3b4dd927d0d29ef33549d8e2c85 +size 149491 diff --git a/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/raw.md b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..ad09475fa613b4c811f2102f1b02c3959c126e46 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00/raw.md @@ -0,0 +1,6421 @@ + + +# --- **O-RAN Work Group 5 (Open F1/W1/E1/X2/Xn interface Workgroup)****O1 Interface specification for O-DU** + +Copyright © 2024 by O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +# Contents + +| | | | +|----|-----------------------------------------------------------------------------------------|----| +| 1 | Contents..... | 2 | +| 2 | List of Figures..... | 8 | +| 3 | List of Tables..... | 8 | +| 4 | Foreword..... | 8 | +| 5 | Modal verbs terminology ..... | 9 | +| 6 | 1 Scope..... | 10 | +| 7 | 2 References..... | 10 | +| 8 | 2.1 Normative references..... | 10 | +| 9 | 2.2 Informative references..... | 11 | +| 10 | 3 Definitions of terms, symbols and abbreviations..... | 11 | +| 11 | 3.1 Terms..... | 11 | +| 12 | 3.2 Symbols..... | 13 | +| 13 | 3.3 Abbreviations..... | 13 | +| 14 | 3.4 Conventions..... | 14 | +| 15 | 3.5 Revision and compatibility handling ..... | 14 | +| 16 | 4 High Level Description ..... | 15 | +| 17 | 4.1 Top level functional description, terminology, including hybrid, hierarchical ..... | 15 | +| 18 | 4.1.1 Architecture for O-RAN WG5 functional split..... | 15 | +| 19 | 4.1.2 O1 interface for O-DU architecture model..... | 15 | +| 20 | 4.1.3 Transport Network ..... | 15 | +| 21 | 4.2 Interfaces..... | 15 | +| 22 | 5 PNF Startup and Registration Management..... | 16 | +| 23 | 5.1 Introduction..... | 16 | +| 24 | 5.2 PNF Plug-n-Play ..... | 16 | +| 25 | 5.3 PNF Registration ..... | 16 | +| 26 | 5.4 NETCONF Connection Establishment..... | 16 | +| 27 | 5.4.1 NETCONF Authentication..... | 16 | +| 28 | 5.5 NETCONF Access Control ..... | 16 | +| 29 | 5.6 NETCONF Protocol Aspects..... | 16 | +| 30 | 5.6.1 Introduction..... | 16 | +| 31 | 5.6.2 NETCONF Capability Discovery ..... | 16 | +| 32 | 5.6.3 NETCONF Session Termination..... | 17 | +| 33 | 5.6.4 NETCONF Session Establishment..... | 17 | +| 34 | 6 Heartbeat Management Services..... | 17 | +| 35 | 6.1 Heartbeat Notification..... | 17 | +| 36 | 6.2 Heartbeat Control..... | 17 | +| 37 | 7 PNF Software Management ..... | 17 | +| 38 | 7.1 Introduction..... | 17 | +| 39 | 7.2 O-DU Software Management ..... | 17 | +| 40 | 7.3 O-RU Software Management ..... | 17 | +| 41 | 7.3.1 Hierarchical Model..... | 17 | +| 42 | 7.3.2 Hybrid Model..... | 22 | +| 43 | 8 Performance Assurance Management..... | 22 | +| 44 | 8.1 Performance Data File Reporting ..... | 22 | +| 45 | 8.1.1 PM File Content ..... | 22 | +| 46 | 8.1.2 PM File Naming..... | 22 | +| 47 | 8.1.3 PM File XML Format ..... | 22 | +| 48 | 8.2 Performance Data Streaming ..... | 22 | +| 49 | 8.3 Performance Assurance Control ..... | 22 | +| 50 | | | + +| | | | | +|----|--------|----------------------------------------------------------------------------------------------|----| +| 1 | 8.3.1 | Performance Assurance Control for O-RU performance counters ..... | 23 | +| 2 | 9 | Fault Supervision Management..... | 23 | +| 3 | 9.1 | General..... | 23 | +| 4 | 9.2 | Definition of the Operations for Fault Events..... | 24 | +| 5 | 9.3 | Definition of Notifications as Fault Events..... | 24 | +| 6 | 9.4 | Message Format for Fault Events ..... | 24 | +| 7 | 9.5 | O-RU Alarms Management by O-DU in Hierarchical Model ..... | 24 | +| 8 | 10 | File Management..... | 25 | +| 9 | 10.1 | Introduction..... | 25 | +| 10 | 10.2 | File Structure ..... | 26 | +| 11 | 10.3 | Notification notifyFileReady ..... | 26 | +| 12 | 10.4 | File Management Operation: listAvailableFiles ..... | 27 | +| 13 | 10.5 | File Management Operation: transferFile..... | 27 | +| 14 | 10.6 | File Management Operation: downloadFile ..... | 27 | +| 15 | 11 | Synchronization Aspects ..... | 27 | +| 16 | 11.1 | Introduction..... | 27 | +| 17 | 11.2 | Synchronization ..... | 28 | +| 18 | 11.2.1 | Synchronization status..... | 28 | +| 19 | 11.2.2 | Synchronization capabilities ..... | 29 | +| 20 | 11.2.3 | Synchronization configuration ..... | 29 | +| 21 | 11.2.4 | PTP configuration ..... | 29 | +| 22 | 11.2.5 | PTP status..... | 30 | +| 23 | 11.2.6 | SyncE configuration..... | 30 | +| 24 | 11.2.7 | SyncE status ..... | 31 | +| 25 | 11.2.8 | GNSS Configuration ..... | 31 | +| 26 | 11.2.9 | GNSS Status..... | 31 | +| 27 | 11.3 | Synchronization master..... | 32 | +| 28 | 11.3.1 | Introduction..... | 32 | +| 29 | 11.3.2 | Synchronization master capabilities ..... | 32 | +| 30 | 11.3.3 | Synchronization master configuration..... | 33 | +| 31 | 11.3.4 | Master PTP status..... | 33 | +| 32 | 11.4 | O-DU and O-RU synchronization relation with cell and carrier activation / in-activation..... | 33 | +| 33 | 11.4.1 | Cell and carrier activation ..... | 33 | +| 34 | 11.4.2 | Cell and carrier in-activation..... | 34 | +| 35 | 12 | Provisioning Management..... | 34 | +| 36 | 12.1 | Introduction..... | 34 | +| 37 | 12.2 | Configuration for Hierarchical Model ..... | 34 | +| 38 | 12.2.1 | Configuration Step ..... | 34 | +| 39 | 12.2.2 | Aggregation model for configuration to O-RU via SMO..... | 35 | +| 40 | 12.3 | Configuration for Hybrid model ..... | 37 | +| 41 | 12.4 | Cell Activation..... | 37 | +| 42 | 12.4.1 | Hierarchical Model..... | 37 | +| 43 | 12.4.2 | Hybrid Model..... | 37 | +| 44 | 12.5 | Notification aspect in hierarchical model ..... | 38 | +| 45 | 12.5.1 | Introduction..... | 38 | +| 46 | 12.5.2 | Subscribing for O-RU notification from SMO..... | 38 | +| 47 | 12.5.3 | Forwarding the notification from O-RU via O-DU ..... | 38 | +| 48 | 13 | Fronthaul Delay Management Support ..... | 40 | +| 49 | 14 | Trace Management Services ..... | 44 | +| 50 | 14.1 | Introduction..... | 44 | +| 51 | 14.2 | Call Trace..... | 44 | +| 52 | 14.3 | Minimization of Drive Testing (MDT)..... | 44 | +| 53 | 14.4 | Radio Link Failure (RLF) ..... | 44 | +| 54 | 14.5 | RRC Connection Establishment Failure (RCEF)..... | 44 | +| 55 | 14.6 | Trace Control..... | 44 | +| 56 | 14.7 | Streaming Trace..... | 44 | + +| | | | | +|----|---------|------------------------------------------------------------------------------|----| +| 1 | 15 | Shared O-RU ..... | 44 | +| 2 | 15.1 | Introduction..... | 44 | +| 3 | 15.2 | Single Operator Shared O-RU ..... | 45 | +| 4 | 15.2.1 | O-DU(s) roles..... | 45 | +| 5 | 15.2.2 | Configuring O-RU ..... | 45 | +| 6 | 15.2.3 | Supervision Monitoring per O-DU..... | 46 | +| 7 | 15.2.4 | NETCONF call home..... | 46 | +| 8 | 15.3 | Multi Operator Shared O-RU..... | 46 | +| 9 | 15.3.1 | O-DU(s) roles..... | 46 | +| 10 | 15.3.2 | Configuring O-RU general OAM related configuration ..... | 47 | +| 11 | 15.3.3 | Managing O-RU general OAM related functions ..... | 47 | +| 12 | 15.3.4 | NETCONF server user account provisioning for shared resource operators ..... | 47 | +| 13 | 15.3.5 | NETCONF call home..... | 47 | +| 14 | 15.3.6 | Enhanced sro-id based NETCONF access control ..... | 48 | +| 15 | 15.3.7 | Supervision Monitoring per O-DU..... | 48 | +| 16 | 15.3.8 | Processing element configuration ..... | 48 | +| 17 | 15.3.9 | Carrier Partitioning and Configuration in Shared O-RU ..... | 48 | +| 18 | 15.3.10 | Notification of configuration updates..... | 48 | +| 19 | 15.3.11 | Shared O-RU Reset Co-ordination ..... | 49 | +| 20 | 15.3.12 | Locked administrative state..... | 49 | +| 21 | 15.3.13 | Antenna calibration ..... | 49 | +| 22 | 15.3.14 | Shared O-RU with antenna line devices..... | 49 | +| 23 | 15.3.15 | Shared O-RU operation in combination with shared cell..... | 49 | +| 24 | 15.4 | Content of Fronthaul M-plane ODU ID..... | 50 | +| 25 | 15.5 | Content of Fronthaul M-plane SRO ID..... | 50 | +| 26 | 16 | Information Model definition..... | 50 | +| 27 | 16.1 | Imported and associated information entities ..... | 50 | +| 28 | 16.1.1 | Imported information entities and local labels ..... | 50 | +| 29 | 16.1.2 | Associated information entities and local labels ..... | 50 | +| 30 | 16.2 | Class diagrams ..... | 50 | +| 31 | 16.2.1 | Relationships ..... | 50 | +| 32 | 16.2.2 | Inheritance..... | 51 | +| 33 | 16.3 | Class definitions..... | 52 | +| 34 | 16.3.1 | SharedOruConfiguration <<IOC>> ..... | 52 | +| 35 | 16.3.2 | SecondaryODuInfo <<dataType>> ..... | 53 | +| 36 | 16.3.3 | CallHomeClientInfo <<dataType>> ..... | 53 | +| 37 | 16.3.4 | NESPolicy <<IOC>> ..... | 54 | +| 38 | 16.4 | Attribute definitions..... | 55 | +| 39 | 17 | O-DU behavior for 3GPP conformance testing ..... | 57 | +| 40 | 17.1 | Introduction..... | 57 | +| 41 | 17.2 | O-DU behavior for O-RU uplink evaluation ..... | 57 | +| 42 | 17.3 | O-DU behavior for O-RU downlink evaluation..... | 57 | +| 43 | | Annex A (informative): Counter definition..... | 58 | +| 44 | A.1 | NR F1 Interface performance counters..... | 58 | +| 45 | A.1.1 | UL PDCP PDUs transmitted via F1-U UL GTP-U tunnel..... | 58 | +| 46 | A.1.2 | UL PDCP PDU volume transmitted via F1-U UL GTP-U tunnel..... | 58 | +| 47 | A.1.3 | Maximum UL PDCP PDU volume transmitted via F1-U UL GTP-U tunnel..... | 59 | +| 48 | A.1.4 | Minimum UL PDCP PDU volume transmitted via F1-U UL GTP-U tunnel ..... | 59 | +| 49 | A.1.5 | DL PDCP PDUs received via F1-U DL GTP-U tunnel ..... | 60 | +| 50 | A.1.6 | DL PDCP PDU volume received via F1-U DL GTP-U tunnel..... | 60 | +| 51 | A.1.7 | Maximum DL PDCP PDU volume received via F1-U DL GTP-U tunnel..... | 61 | +| 52 | A.1.8 | Minimum DL PDCP PDU volume received via F1-U DL GTP-U tunnel..... | 61 | +| 53 | A.1.9 | Transmitted F1-C messages..... | 62 | +| 54 | A.1.10 | Received F1-C messages ..... | 62 | +| 55 | A.1.11 | DL F1-U packets discarded due to NR U-Plane protocol error ..... | 62 | +| 56 | A.1.12 | DL F1-U packet loss rate ..... | 63 | +| 57 | A.1.13 | DL Packet Drop Rate in gNB-DU ..... | 63 | +| 58 | A.1.14 | UL PDCP PDU volume transmitted via F1-U UL GTP-U tunnel ..... | 64 | +| 59 | A.1.15 | DL PDCP PDU volume received via F1-U DL GTP-U tunnel..... | 65 | + +| | | | +|----|------------------------------------------------------------------------------|----| +| 1 | A.2 NR RLC performance counters ..... | 65 | +| 2 | A.2.1 Received UL RLC PDUs ..... | 65 | +| 3 | A.2.2 Received UL RLC PDU volume ..... | 66 | +| 4 | A.2.3 Request for UL RLC PDUs retransmission ..... | 66 | +| 5 | A.2.4 Transmitted DL RLC PDUs ..... | 67 | +| 6 | A.2.5 Transmitted DL RLC PDU volume ..... | 67 | +| 7 | A.2.6 Retransmitted DL RLC PDUs ..... | 67 | +| 8 | A.2.7 Retransmitted DL RLC PDU volume ..... | 68 | +| 9 | A.2.8 UL RLC PDUs discarded due to bearer release ..... | 68 | +| 10 | A.2.9 UL RLC PDU volume discarded due to bearer release ..... | 69 | +| 11 | A.2.10 UL RLC PDUs discarded due to RLC re-establishment ..... | 69 | +| 12 | A.2.11 UL RLC PDU volume discarded due to RLC re-establishment ..... | 70 | +| 13 | A.2.12 UL RLC PDUs discarded due to other causes ..... | 70 | +| 14 | A.2.13 UL RLC PDU volume discarded due to other causes ..... | 71 | +| 15 | A.2.14 DL RLC PDUs discarded due to bearer release ..... | 71 | +| 16 | A.2.15 DL RLC PDU volume discarded due to bearer release ..... | 71 | +| 17 | A.2.16 DL RLC PDUs discarded due to RLC re-establishment ..... | 72 | +| 18 | A.2.17 DL RLC PDU volume discarded due to RLC re-establishment ..... | 72 | +| 19 | A.2.18 DL RLC PDUs discarded due to full buffer ..... | 73 | +| 20 | A.2.19 DL RLC PDU volume discarded due to full buffer ..... | 73 | +| 21 | A.2.20 The number of exceeding maximum RLC retransmissions ..... | 74 | +| 22 | A.2.21 Average delay DL in gNB-DU ..... | 74 | +| 23 | A.2.22 IP Latency DL in gNB-DU ..... | 75 | +| 24 | A.2.23 Received paging records ..... | 75 | +| 25 | A.2.24 Discarded paging records ..... | 76 | +| 26 | A.3 NR MAC performance counters ..... | 76 | +| 27 | A.3.1 Received UL MAC PDU volume ..... | 76 | +| 28 | A.3.2 Transmitted DL MAC PDU volume ..... | 76 | +| 29 | A.3.3 Average delay DL air-interface ..... | 77 | +| 30 | A.4 NR UL HARQ performance counters ..... | 78 | +| 31 | A.4.1 Distribution of PUSCH per MCS (initial transmission) ..... | 78 | +| 32 | A.4.2 Distribution of PUSCH per MCS (initial transmission/CRC OK) ..... | 78 | +| 33 | A.4.3 Distribution of PUSCH per MCS (any/CRC OK) ..... | 79 | +| 34 | A.4.4 Distribution of PUSCH per MCS (exceeding HARQ retransmission) ..... | 80 | +| 35 | A.4.5 Distribution of PUSCH per MCS (MU-MIMO/initial transmission) ..... | 80 | +| 36 | A.4.6 Distribution of PUSCH per MCS (MU-MIMO/initial transmission/ACK) ..... | 81 | +| 37 | A.5 NR DL HARQ performance counters ..... | 82 | +| 38 | A.5.1 Distribution of PDSCH per MCS (initial transmission) ..... | 82 | +| 39 | A.5.2 Distribution of PDSCH per MCS (initial transmission/ACK) ..... | 82 | +| 40 | A.5.3 Distribution of PDSCH per MCS (any/ACK) ..... | 83 | +| 41 | A.5.4 Distribution of PDSCH per MCS (exceeding HARQ retransmission) ..... | 84 | +| 42 | A.5.5 Distribution of PDSCH per MCS (MU-MIMO/initial transmission) ..... | 84 | +| 43 | A.5.6 Distribution of PDSCH per MCS (MU-MIMO/initial transmission/ACK) ..... | 85 | +| 44 | A.6 NR UL Signal Quality Level performance counters ..... | 85 | +| 45 | A.6.1 Distribution of PUSCH per MCS (Rank1) ..... | 85 | +| 46 | A.6.2 Distribution of PUSCH per MCS (Rank2) ..... | 86 | +| 47 | A.6.3 Distribution of PUSCH per SSB (Rank1) ..... | 87 | +| 48 | A.6.4 Distribution of PUSCH per SSB (Rank2) ..... | 87 | +| 49 | A.6.5 PUSCH received power ..... | 88 | +| 50 | A.6.6 PUSCH RSSI ..... | 89 | +| 51 | A.6.7 PUSCH SINR ..... | 89 | +| 52 | A.6.8 PUCCH RSSI ..... | 90 | +| 53 | A.6.9 PUCCH SINR ..... | 91 | +| 54 | A.6.10 PRACH preamble correlation value ..... | 92 | +| 55 | A.6.11 RSSI of PRACH transmission occasion ..... | 93 | +| 56 | A.6.12 Distribution of path loss for FR1 ..... | 93 | +| 57 | A.6.13 Path loss for FR2 ..... | 94 | +| 58 | A.6.14 Detection of UL out-of-sync ..... | 95 | +| 59 | A.7 NR DL Signal Quality Level performance counters ..... | 95 | +| 60 | A.7.1 Distribution of PDSCH per MCS (Rank1) ..... | 95 | + +| | | | +|----|------------------------------------------------------------------------------------------------|-----| +| 1 | A.7.2 Distribution of PDSCH per MCS (Rank2) ..... | 96 | +| 2 | A.7.3 Distribution of PDSCH per MCS (Rank3) ..... | 97 | +| 3 | A.7.4 Distribution of PDSCH per MCS (Rank4) ..... | 97 | +| 4 | A.7.5 Distribution of PDSCH per SSB (Rank1) ..... | 98 | +| 5 | A.7.6 Distribution of PDSCH per SSB (Rank2) ..... | 98 | +| 6 | A.7.7 Distribution of PDSCH per SSB (Rank3) ..... | 99 | +| 7 | A.7.8 Distribution of PDSCH per SSB (Rank4) ..... | 99 | +| 8 | A.7.9 Distribution of Wideband CQI for FR1 ..... | 99 | +| 9 | A.7.10 Wideband CQI for FR2 ..... | 100 | +| 10 | A.7.11 PDCCH transmission power ..... | 101 | +| 11 | A.8 NR Beamforming performance counters ..... | 102 | +| 12 | A.8.1 Distribution of UEs per beam index ..... | 102 | +| 13 | A.8.2 Best and Second Best Beam distribution ..... | 103 | +| 14 | A.8.3 UE reported differential L1-RSRP of second best beam ..... | 103 | +| 15 | A.9 NR RACH Usage performance counters ..... | 104 | +| 16 | A.9.1 Received preambles in group A ..... | 104 | +| 17 | A.9.2 The number of received dedicated preamble ..... | 104 | +| 18 | A.9.3 Transmitted RARs for preamble in group A ..... | 104 | +| 19 | A.9.4 Transmitted RARs for dedicated preamble ..... | 105 | +| 20 | A.9.5 Failures at assignment of dedicated preamble ..... | 105 | +| 21 | A.9.6 Occasions for dedicated preamble reception ..... | 106 | +| 22 | A.9.7 Failures at assignment of a dedicated preamble for PDCCH order RA (UL out-of-sync) ..... | 106 | +| 23 | A.10 NR Timing Advance performance counters ..... | 107 | +| 24 | A.10.1 Distribution of N <sub>TA</sub> value of RAR message ..... | 107 | +| 25 | A.11 NR Cell Utilization performance counters (Type A) ..... | 108 | +| 26 | A.11.1 Slots at which PDCCH resource shortage occurred ..... | 108 | +| 27 | A.11.2 Canceled DCI due to PDCCH resource shortage ..... | 108 | +| 28 | A.11.3 Maximum UEs buffering UL/DL data ..... | 108 | +| 29 | A.11.4 Maximum UEs buffering UL data ..... | 109 | +| 30 | A.11.5 Maximum UEs buffering DL data ..... | 109 | +| 31 | A.11.6 Multiplexed transmissions of PUSCH ..... | 110 | +| 32 | A.11.7 Multiplexed receptions of PDSCH ..... | 110 | +| 33 | A.11.8 Maximum DRX inactive UEs ..... | 111 | +| 34 | A.11.9 Maximum DRX active UEs ..... | 111 | +| 35 | A.11.10 Distribution of trafficInactivityTimer ..... | 112 | +| 36 | A.11.11 Slots in which scheduler assigned as mini slot ..... | 112 | +| 37 | A.11.12 Mini slots in which PUSCH was received ..... | 112 | +| 38 | A.11.13 UEs in the cell using this cell as PSCell or having activated SCell in DL ..... | 113 | +| 39 | A.11.14 UEs in the cell using this cell as PSCell or having activated SCell in UL ..... | 113 | +| 40 | A.11.15 Distribution of PSCell UEs with X activated SCells in UL ..... | 114 | +| 41 | A.11.16 Distribution of PSCell UEs with X activated SCells in DL ..... | 114 | +| 42 | A.11.17 Maximum amount of PSCell UEs (UL) ..... | 115 | +| 43 | A.11.18 Minimum amount of PSCell UEs (UL) ..... | 115 | +| 44 | A.11.19 Maximum amount of PSCell UEs (DL) ..... | 116 | +| 45 | A.11.20 Minimum amount of PSCell UEs (DL) ..... | 116 | +| 46 | A.11.21 Activation/Deactivation MAC CE (SCell Active) ..... | 117 | +| 47 | A.11.22 Activation/Deactivation MAC CE (SCell Deactive) ..... | 117 | +| 48 | A.11.23 Distribution of DL Total PRB Usage ..... | 117 | +| 49 | A.11.24 Distribution of UL Total PRB Usage ..... | 118 | +| 50 | A.11.25 Average DL Cell throughput ..... | 119 | +| 51 | A.11.26 Average UL Cell throughput ..... | 120 | +| 52 | A.11.27 Average DL Beam throughput ..... | 120 | +| 53 | A.11.28 Average UL Beam throughput ..... | 121 | +| 54 | A.11.29 Average DL active DRB ..... | 121 | +| 55 | A.11.30 Maximum DL active DRB ..... | 122 | +| 56 | A.11.31 Mean DL PRB used for data traffic ..... | 122 | +| 57 | A.11.32 Mean UL PRB used for data traffic ..... | 123 | +| 58 | A.11.33 Distribution of UL UE throughput in gNB ..... | 123 | + +| | | | +|----|---------------------------------------------------------------------------------|-----| +| 1 | A.11.34 Distribution of DL UE throughput in gNB ..... | 125 | +| 2 | A.11.35 Distribution of DL packet drop rate ..... | 126 | +| 3 | A.11.36 PDCCH for BWP switching ..... | 127 | +| 4 | A.11.37 Distribution of Activated BWP ID ..... | 128 | +| 5 | A.11.38 Non-linear Scale Distribution of UL UE throughput in gNB ..... | 128 | +| 6 | A.11.39 Non-linear Scale Distribution of DL UE throughput in gNB ..... | 129 | +| 7 | A.12 NR Cell Utilization performance counters (Type B) ..... | 130 | +| 8 | A.12.1 PUSCH slots ..... | 130 | +| 9 | A.12.2 PDSCH slots ..... | 131 | +| 10 | A.12.3 PDCCH slots ..... | 131 | +| 11 | A.12.4 CCE utilization rate ..... | 131 | +| 12 | A.12.5 UEs buffering UL/DL data ..... | 132 | +| 13 | A.12.6 UEs buffering UL data ..... | 132 | +| 14 | A.12.7 UEs buffering DL data ..... | 133 | +| 15 | A.12.8 DRX inactive UEs ..... | 133 | +| 16 | A.12.9 DRX active UEs ..... | 133 | +| 17 | A.12.10 PDSCH slot for paging ..... | 134 | +| 18 | A.13 O-RU Performance counters measured at O-DU ..... | 134 | +| 19 | A.13.1 Uplink data and control frames received in total ..... | 134 | +| 20 | A.13.2 Uplink data frames received on Time ..... | 135 | +| 21 | A.13.3 Uplink data frames received too early ..... | 135 | +| 22 | A.13.4 Uplink data frames received too late ..... | 135 | +| 23 | A.13.5 Uplink control frames received on Time ..... | 136 | +| 24 | A.13.6 Uplink control frames received too early ..... | 136 | +| 25 | A.13.7 Uplink control frames received too late ..... | 136 | +| 26 | A.13.8 Uplink data frames with detecting sequence identifier error ..... | 137 | +| 27 | A.13.9 Uplink control frames with detecting sequence identifier error ..... | 137 | +| 28 | A.13.10 Uplink frames with corrupt contents ..... | 138 | +| 29 | A.13.11 Uplink frames dropped and discarded ..... | 138 | +| 30 | A.13.12 Downlink control and data frames transmitted ..... | 138 | +| 31 | A.13.13 Downlink control frames transmitted to O-RU in total at O-DU ..... | 139 | +| 32 | A.14 O-RU Performance counters measured at O-RU ..... | 139 | +| 33 | Annex B (informative): Optional Multi-Vendor Functionality ..... | 139 | +| 34 | B.1: Optional Namespace Exposed Using O-RAN WG5 Models ..... | 139 | +| 35 | B.2: Optional Namespace Exposed Using O-RAN WG4 Models ..... | 140 | +| 36 | B.3: Optional YANG Features Exposed Using O-RAN WG5 Models ..... | 140 | +| 37 | B.4: Optional YANG Features Exposed Using O-RAN WG4 Models ..... | 140 | +| 38 | B.5: Optional YANG Features Exposed Using Common Models ..... | 141 | +| 39 | B.6: Optional Capabilities Exposed Using O-RAN WG5 Models ..... | 142 | +| 40 | B.7: Optional Capabilities Exposed Using O-RAN WG4 Models ..... | 142 | +| 41 | B.8: Optional Capabilities Exposed Using Common Models ..... | 144 | +| 42 | Annex C (informative): YANG Module Graphical Representation ..... | 144 | +| 43 | C.1 Additional configuration folder ..... | 144 | +| 44 | C.2 Common Models folder ..... | 144 | +| 45 | C.2.1 o-ran-dhcp.yang Module ..... | 144 | +| 46 | C.2.2 o-ran-synchronization.yang Module ..... | 145 | +| 47 | C.2.3 o-ran-wg5-delay-management Module ..... | 146 | +| 48 | C.3 DU Specific Models folder ..... | 147 | +| 49 | C.3.1 o-ran-aggregation-base.yang Module ..... | 147 | +| 50 | C.3.2 o-ran-o1-ctiOdu.yang Module ..... | 147 | +| 51 | C.3.2 o-ran-o-du-shared-o-ru.yang ..... | 149 | +| 52 | C.4 Provisioning folder ..... | 149 | +| 53 | C.5 CTI folder ..... | 149 | +| 54 | Annex D (informative): WG4 instance categories in Hierarchical Model ..... | 150 | +| 55 | Annex E (informative): Parameters definition for 3GPP conformance testing ..... | 150 | +| 56 | Annex F (informative): Network Energy Saving ..... | 153 | +| 57 | F.1 Introduction ..... | 153 | + +| | | +|------------------------------------------------------|-----| +| F.2 Cell and carrier deactivation / activation ..... | 153 | +| F.2.1 Flow description ..... | 153 | +| F.3 RF Channel Reconfiguration ..... | 155 | +| F.3.1 Flow description ..... | 155 | +| F.4 Advanced Sleep Modes ..... | 158 | +| F.4.1 Flow description ..... | 158 | +| Revision History ..... | 163 | + +## List of Figures + +| | | +|---------------------------------------------------------------------------------------------------------------|-----| +| Figure 7-1: Software Inventory ..... | 19 | +| Figure 7-2: Software Download ..... | 20 | +| Figure 7-3: Software Activate ..... | 21 | +| Figure 9-1: Operation to merge O-RU Alarms by O-DU ..... | 24 | +| Figure 10-1: File Ready Notification ..... | 27 | +| Figure 11-1: Allowed sync state transitions ..... | 29 | +| Figure 12-1: Cell activation procedure ..... | 37 | +| Figure 12-2: Notification to the SMO preceded by the O-RU notification ..... | 39 | +| Figure 12-3: Notification to the SMO preceded by the O-DU <get> operation ..... | 39 | +| Figure 13-1: Delay Management Configuration Procedure ..... | 43 | +| Figure 16-1: SharedOruConfiguration containment ..... | 50 | +| Figure 16-2: RF Channel Reconfiguration (TRx Control) (NESPpolicy) containment ..... | 51 | +| Figure 16-3: AdvancedSleepMode (NESPpolicy) containment ..... | 51 | +| Figure 16-4: SharedOruConfiguration inheritance ..... | 51 | +| Figure 16-5: Network Energy Saving (NESPpolicy) inheritance ..... | 52 | +| Figure F.1: Network Energy Saving - Cell and carrier deactivation / activation use case ..... | 154 | +| Figure F.2: Common flow for Network Energy Saving use cases for RF Channel Reconfiguration ..... | 156 | +| Figure F.3: Network Energy Saving - RF Channel Reconfiguration use case based on policies known to O-DU ..... | 158 | +| Figure F.4: Network Energy Saving use cases for Advanced Sleep Modes ..... | 160 | +| Figure F.5: Network Energy Saving - Advanced Sleep Mode use case based on policies known to O-DU ..... | 162 | + +## List of Tables + +| | | +|--------------------------------------------------------------------------------------------------|-----| +| Table 1: Mapping of O-RU NETCONF based fault notification to ONAP VES in ‘fault3gppFields’ ..... | 25 | +| Table 2: Parameters list for Notification notifyFileReady ..... | 26 | +| Table 3: Optional O-RAN WG5 Namespace ..... | 139 | +| Table 4: Optional O-RAN WG4 Namespace ..... | 140 | +| Table 5: Optional O-RAN WG5 defined feature support ..... | 140 | +| Table 6: Optional O-RAN WG4 defined feature support ..... | 141 | +| Table 7: Optional feature support in common models ..... | 142 | +| Table 8: Optional capabilities in O-RAN WG5 defined YANG models ..... | 142 | +| Table 9: Optional capabilities in O-RAN WG4 defined YANG models ..... | 143 | +| Table 10: Optional capabilities in common YANG models ..... | 144 | +| Table 11: Categories for YANG parameters ..... | 150 | +| Table 12: Parameters for O-RU uplink evaluation ..... | 152 | +| Table 13: Parameters for O-RU downlink evaluation ..... | 152 | + +## Foreword + +This Technical Specification (TS) has been produced by WG5 of the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN WG5 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +--- + +## Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are NOT allowed in O-RAN deliverables except when used in direct citation. + +# 1 Scope + +The present document specifies the O1 Interface specification for O-DU used over the interface linking the O-DU (O-RAN Distributed Unit) with other management plane entities, that may include the O-CU (O-RAN Central Unit) as well as Service Management and Orchestration (SMO). + +## 2 References + +### 2.1 Normative references + +References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 17. + +The following referenced documents are necessary for the application of the present document. + +- [1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications” +- [2] ORAN-WG4.MP.0-v12.00 “Management Plane Specification”, O-RAN Alliance, Working Group 4 +- [3] RFC 6187, “X.509v3 Certificates for Secure Shell Authentication”, IETF, March 2011 +- [4] RFC 4253, “The Secure Shell (SSH) Transport Layer Protocol”, IETF, January 2006 +- [5] O-RAN-WG10.OAM-Architecture-v09.00, O-RAN Alliance, Working Group 10 +- [6] O-RAN.WG10.O1-Interface.0-v10.00, “O-RAN Operations and Maintenance Interface Specification”, O-RAN Alliance, Working Group 10 +- [7] 3GPP 28.545, “Management and orchestration; Fault Supervision (FS)”, 3GPP, v16.1.0, 2020-09 +- [8] 3GPP 28.541, “Management and orchestration; 5G Network Resource Model (NRM)”, 3GPP, v17.4.0, 2021-04 +- [9] ORAN-WG4.CUS.0-v12.00 “Control, User and Synchronization Plane Specification”, O-RAN Alliance, Working Group 4 +- [10] 3GPP 32.342, “File Transfer (FT); Integration Reference Point (IRP)”, 3GPP, v17.0.0, 2022-04 +- [11] 3GPP 32.302, “Configuration Management (CM); Notification Integration Reference Point (IRP)”, 3GPP, v16.0.0, 2020-07 +- [12] O-RAN.SFG.O-RAN-Security-Requirements-Specifications-v01.00 “O-RAN Security Requirements Specification”, O-RAN Alliance, Security Focus Group +- [13] 3GPP TS 28.622: Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS), 3GPP, v16.7.1, 2021-04 +- [14] 3GPP TS 28.552: “Management and orchestration; 5G performance measurements”, 3GPP, v17.4.0 (2021-09) +- [15] RFC 7589, “Using the NETCONF Protocol over Transport Layer Security (TLS) with Mutual X.509 Authentication”, IETF, June 2015 +- [16] 3GPP TS 38.141-1: “Base Station (BS) conformance testing Part 1: Conducted conformance testing”, 3GPP, v16.9.0 (2021-10) +- [17] 3GPP TS 38.141-2: “Base Station (BS) conformance testing Part 2: Radiated conformance testing”, 3GPP, v16.9.0 (2021-10) +- [18] 3GPP TS 38.104: “Base Station (BS) radio transmission and reception”, 3GPP, v16.9.0 (2021-10) + +## 2.2 Informative references + +References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 17. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +[i.1] RFC 6241, “Network Configuration Protocol (NETCONF)”, IETF, June 2011 + +[i.2] G.8275.1, “Precision time protocol telecom profile for phase/time synchronization with full timing support from the network”, ITU, June 2016 + +[i.3] G.8275.2, “Precision time protocol telecom profile for phase/time synchronization with partial timing support from the network”, ITU, March 2020 + +[i.4] G.810, “Definitions and terminology for synchronization networks”, ITU, August 1996 + +[i.5] 1588v2-2008, “IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems”, IEEE, 2008 + +[i.6] G.8261, “Timing and synchronization aspects in packet networks”, ITU, August 2019 + +[i.7] RFC 6933, “Entity MIB (Version 4)”, IETF, May 2013 + +[i.8] RFC 4268, “Entity State MIB”, IETF, November 2005 + +[i.9] RFC 3433, “Entity Sensor Management Information Base”, IETF, December 2002 + +[i.10] RFC 2863, “The Interfaces Group MIB”, IETF, June 2000 + +[i.11] O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00, O-RAN Alliance, Working Group 1. + +## 3 Definitions of terms, symbols and abbreviations + +### 3.1 Terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [1]. + +**Advanced Sleep Mode (ASM):** Advanced sleep mode may be used to achieve energy saving by disabling some fraction of the O-RU’s processing for a defined or undefined period of time. + +**Antenna Line:** connection between O-RU and antenna + +**C-Plane:** Control Plane: refers specifically to real-time control between O-DU and O-RU, and should not be confused with the UE’s control plane + +**c\_eAxC:** component eAxC: a portion of an eAxC flow assigned to a specific O-DU processing element. + +**DL:** Downlink: data flow towards the radiating antenna (generally on the LLS interface) + +**DU:** Distributed Unit: a logical node hosting RLC/MAC/High-PHY/Low-PHY layers and RF processing layers based on a higher layer functional split for integrated model + +**eAxC:** extended Antenna-Carrier: a data flow for a single antenna (or spatial stream) for a single carrier in a single sector. + +**Emergency Wake-up:** In TRX Control and Advanced Sleep Mode energy saving techniques, the CU-Plane processing unit of O-RU may be turned off, hence O-DU can’t wake-up the O-RU from sleep through C-Plane. When C-Plane is disabled, M-Plane shall be used to abort the ongoing Advanced Sleep Modes and TRX Control. + +**Energy Saving Policy:** A set of rules and conditions defined by the MnS Consumer that, when provided to O-DU, shall be used by O-DU to decide when and for how long to utilize specific type of Energy Saving. As such, Energy Saving + +Policy is not exact command that triggers addressee to immediately apply specific Advanced Sleep Mode or to activate / deactivate cells / carriers. + +Note: It is not prohibited for single policy to contain rules and conditionals for more than one Energy Saving Mode. + +**FFT/iFFT:** Fast Fourier Transform/inverse Fast Fourier Transform: an algorithm that computes discrete Fourier transform or its inverse. + +**High-PHY:** those portions of the PHY processing on the O-DU side of the fronthaul interface, including FEC encode/decode, scrambling, and modulation/demodulation. + +**IOC:** Information Object Class. + +**LLS:** Lower Layer Split: logical interface between O-DU and O-RU when using a lower layer (intra-PHY based) functional split. + +**LLS-C:** Lower Layer Split Control-plane: logical interface between O-DU and O-RU when using a lower layer functional split. + +**Low-PHY:** those portions of the PHY processing on the O-RU side of the fronthaul interface, including FFT/iFFT, digital beamforming, and PRACH extraction and filtering. + +**M-Plane:** Management Plane: refers to non-real-time management operations between the O-DU and the O-RU + +**MnS Consumer:** The Network Element that consumes and utilizes Management Services (here SMO or non-RT RIC). + +**MnS Producer:** The Network Element that produces Management Services (here O-DU or O-CU). + +**Multi O-DU O-RU:** An O-RU that supports the **SHARED-ORU-MULTI-ODU** feature + +**Multi-Operator O-RU:** An O-RU that supports the **SHARED-ORU-MULTI-OPERATOR** and **SHARED-ORU-MULTI-ODU** features + +**O-CU:** O-RAN Central Unit: a logical node hosting in the Control Plane (O-CU-CP) the RRC and the Control Plane part of the PDCP protocol and in the User Plane (O-CU-UP) the user plane part of the PDCP protocol and the SDAP protocol. + +**O-CU-CP:** O-RAN Central Unit: Control Plane: a logical node hosting the RRC and the control plane part of the PDCP protocol. + +**O-CU-UP:** O-RAN Central Unit: User Plane: a logical node hosting the user plane part of the PDCP protocol and the SDAP protocol. + +**O-DU:** O-RAN Distributed Unit — A logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. + +**O-RU:** O-RAN Radio Unit: a logical node hosting Low-PHY layer and RF processing based on a higher layer functional split in 3-box model. This is similar to 3GPP's "TRP" or "RRH" but more specific in including the Low-PHY layer (FFT/iFFT, PRACH extraction). + +**Port:** End of a transport link – in most cases this is an optical port + +**Port Number:** A number which identifies a port (see Port). In case of SFP/SFP+ port, port number value is 0 to N-1 where N is number of ports in the device. Numbers 0 to N-1 are assigned to ports in order following order of labels on the device (labels for ports are not necessarily numbers starting from zero) + +**S-Plane:** Synchronization Plane: refers to traffic between the O-RU or O-DU to a synchronization controller which is generally an IEEE-1588 Grand Master (however, Grand Master functionality may be embedded in the O-DU). + +**Shared O-RU Host:** The role performed by the NETCONF client associated with the operator of a Multi-Operator O-RU who determines how the resources of a Multi-Operator O-RU are partitioned between Shared Resource Operators. + +**Shared O-RU Host O-DU:** The O-DU performing Shared O-RU Host role. + +**Shared Resource Operator:** The role performed by the NETCONF client associated with an operator that utilizes the carrier resources of a Multi-Operator O-RU. The Shared Resource Operator is allocated a Shared Resource Operator identity by the Shared O-RU Host. + +NOTE: A NETCONF client of an operator can simultaneously perform the Shared O-RU Host role and the Shared Resource Operator role. Alternatively, a NETCONF client of an operator can only perform the Shared O-RU Host role and not Shared Resource Operator role, in which case the operator corresponds to a neutral host operator. + +**Shared Resource Operator O-DU:** The O-DU performing Shared Resource Operator role. + +**Spatial stream:** the data flow on the DL associated with precoded data (may be same as layers or different if there is expansion in the precoding), and on UL associated with the number of outputs from the digital beamforming (sometimes called “beams”). + +**SSM:** Synchronization Status Message: part of ITU G.781 and G.8264 standards. + +**TRX Control:** TRX control may be used to achieve energy saving through disabling one or more O-RU antenna array elements for a defined or undefined period of time. + +**U-Plane:** User Plane: refers to IQ sample data between O-DU and O-RU. + +**UL:** Uplink: data flow away from the radiating antenna (generally on the LLS interface) + +## 3.2 Symbols + +For the purposes of the present document, the symbols [given in 3GPP TR 21.905 [1] and the following apply. A symbol defined in the present document takes precedence over the definition of the same symbol, if any, in 3GPP TR 21.905 [1]. + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [1]. + +| | | +|-------|--------------------------------------| +| ALD | Antenna Line Device | +| ASM | Advanced Sleep Mode | +| AVP | Average Power | +| BCN | BTS Clock Number | +| CRC | Cyclic Redundancy Check | +| CUS | Control/User/Synchronization | +| CU-CP | Central Unit Control Plane | +| CU-UP | Central Unit User Plane | +| DHCP | Dynamic Host Configuration Protocol | +| DMTC | DRS Measurement Timing Configuration | +| DRS | Discovery Reference Signal | +| DSCP | Differentiated Services Code Point | +| DU | Distributed Unit | +| ESP | Energy Saving Policy | +| FH | Fronthaul | +| HDLC | High-Level Data Link Control | +| lls-M | Lower Layer Split Management plane | +| LAA | Licensed Assisted Access | +| LBM | Loop-Back Message | +| LBR | Loop Back Reply | +| LBT | Listen Before Talk | +| ME | Maintenance Entity | +| MEP | Maintenance association End Point | +| MnS | Management Service | + +| | | | +|----|---------|-------------------------------------------------------------| +| 1 | NAT | Network Address Translation | +| 2 | NES | Network Energy Saving | +| 3 | NETCONF | Network Configuration Protocol | +| 4 | NMS | Network Management System | +| 5 | O-CU | O-RAN Central Unit | +| 6 | O-CU-CP | O-RAN Central Unit Control Plane | +| 7 | O-CU-UP | O-RAN Central Unit User Plane | +| 8 | O-DU | O-RAN Distributed Unit | +| 9 | O-RU | O-RAN Radio Unit | +| 10 | PDV | Packet Delay Variation | +| 11 | PNF | Physical Network Function | +| 12 | QoS | Quality of Service | +| 13 | RET | Remote Electrical Tilt | +| 14 | RPC | Remote Procedure Call | +| 15 | SFP | Small Form-factor Pluggable | +| 16 | sFTP | Secure File Transfer Protocol or SSH File Transfer Protocol | +| 17 | SLAAC | Stateless Address Auto Configuration | +| 18 | SMO | Service Management and Orchestration | +| 19 | SRO | Shared Resource Operator | +| 20 | SSH | Secure Shell | +| 21 | TRX | Transceiver | +| 22 | VLAN | Virtual LAN | +| 23 | YANG | Yet Another Next Generation | + +24 + +## 3.4 Conventions + +26 This management plane specification includes cross references to a set of associated YANG models. Text may reference +27 particular YANG leafs, notifications and remote procedure calls (RPCs). In order to assist in readability, all cross +28 references to YANG defined elements will keep the identical case format as defined in the corresponding YANG model, +29 with the font-weight set to **bold**. This convention applies only to text and not to YANG elements embedded into figures. + +30 If there is any conflict between the YANG models and the accompanying text description in this specification, the +31 definition of the YANG models shall take precedence. + +32 + +## 3.5 Revision and compatibility handling + +34 The revision statement in the YANG models shall be used to describe future revisions to the models that are backwards +35 compatible. Backwards incompatible changes will be addressed by incrementing the number used as part of the model +36 name and namespace, effectively creating a new YANG model. The format of the namespace used in all O-RAN YANG +37 models is “urn:o-ran:”<model-name>“:”<model-number>, where the initial <model-number> used in a newly defined +38 YANG model is “1.0”. Where this document makes reference to models, irrespective of their backward compatibility, a +39 generic <model-number> of “x.y” is used to enable reference to all versions of the namespace for a particular <model- +40 name>. + +41 + +The revision statement in all YANG models includes a reference statement used to cross-reference to the first version of this document where the corresponding description was introduced. For example, the reference in all revision statements for the initial O-RAN models include cross-reference to “ORAN-WG5.MP.0-v01.00”. + +The revision statement of the YANG models also includes a description which is used to track the versioning of the YANG model. All revision statement descriptions will begin with “version ”<a>“.”<b>“.”<c>, where <a>, <b> and <c> are used to reflect the version of the YANG model, where + +- <a> corresponds to the first digit of the O-RAN WG5 O1 interface specification for O-DU version where the corresponding description was first introduced, corresponding to <x> in subclause 1.1 +- <b> is incremented when errors in the YANG model have been corrected +- <c> is incremented only in working versions of the YANG model indicating incremental changes during the editing process + +## 4 High Level Description + +### 4.1 Top level functional description, terminology, including hybrid, hierarchical + +#### 4.1.1 Architecture for O-RAN WG5 functional split + +This O1 interface facilitates the initialization, configuration and management of the O-DU to support the functional split. Please refer to O-RAN OAM Architecture [i.5] for more details on architecture and functional split. + +#### 4.1.2 O1 interface for O-DU architecture model + +O1 interface for O-DU is used for supporting the management features including “start up” installation, PNF software management, provisioning management, performance management, fault management and file management towards the O-DU. + +The O1 interface for O-DU is also used to support O-RU management. For this purpose, specific models are used to aggregate the configuration of individual O-RU functions (deployed as separate entities) and present them over the O1 interface of the O-DU(s) connected to them. The management of these O-RUs may be performed according to either Hierarchical model or Hybrid model, depending on the particular deployment; see clause 12 for details regarding these two models. + +#### 4.1.3 Transport Network + +Based on the transport topology, various modes of network connectivity are possible between O-DU and O-CU and SMO. + +The basic requirement for O1 interface for O-DU is to have end to end IP connectivity between the O-DU and the elements managing it. The O-DU shall support either IPv4 or IPv6 and optionally support dual stack (IPv4 and IPv6). + +This version of the O1 interface for O-DU has not been defined to be able to operate in the presence of any Network Address Translation (NAT) between the O-DU and elements managing it. + +## 4.2 Interfaces + +The interface between the management system and the O-DU is O1. The general requirement for O1 interface for O-DU is aligned with [6], clause 4 General Requirements. + +Heartbeat Notification for O-DU is aligned with [6], clause 6.6.1 Heartbeat Notification. + +## 5 PNF Startup and Registration Management + +### 5.1 Introduction + +O-DU may be deployed as PNF as described in O1 Interface Specification 0, clause 6.7 PNF Startup and Registration Management Services. + +### 5.2 PNF Plug-n-Play + +PNF Plug-n-Play for O-DU is aligned with O1 Interface Specification 0, clause 6.7.1 PNF Plug-n-Play. + +### 5.3 PNF Registration + +PNF Registration for O-DU is aligned with O1 Interface Specification 0, clause 6.7.2 PNF Registration. + +### 5.4 NETCONF Connection Establishment + +#### 5.4.1 NETCONF Authentication + +This version of the O1 Specification uses mutual authentication based on X.509 certificates [3]. + +Mutual Public key-based client/server authentication shall be used for authenticating the server (RFC 4253 [4]) by the clients. and authenticating the client by the server. + +For the purposes of NETCONF user authentication, the mapping between certificates and user-names is provided by the SubjectAltName field of the X.509 certificate [3], which means that the user name is coded in the subjectAltName. The username is determined from the subjectAltName using the rules defined in RFC 7589 [15]. + +Note: In RFC7589, different user-name and SubjectAltName mappings are possible. O-RAN SFG is working on extensive solution designed for O1 interface. Further alignment with generic O1 Interface Specification [6] will be needed once done. + +### 5.5 NETCONF Access Control + +This subclause provides the access control for NETCONF client. Its motivation is when multiple NETCONF clients (users) exist, access control mechanism allows to limit some operation for one client but full access for the other client. + +For the O1 interface, in order to support interoperable access control management, the NETCONF Server shall follow privilege access control requirements which are specified in O-RAN Security Requirements Specification [12] clause 3.2.2.1.2. + +For accessing O-RU YANG data models access control please refer to clause 6.5 of [2]. + +### 5.6 NETCONF Protocol Aspects + +#### 5.6.1 Introduction + +This clause covers aspects of NETCONF protocol usage by the O-DU. For full list of supported services please refer to clause 6.1 of [6]. + +#### 5.6.2 NETCONF Capability Discovery + +The O-DU advertises its NETCONF capabilities in the NETCONF Hello message. The Hello message provides an indication of support for standard features defined in NETCONF RFCs [i.1] as well as support for specific namespaces. + +NETCONF capabilities are exchanged between the O-DU and the NETCONF client(s). + +For full list of supported operations and capabilities please refer to clause 6.1.1. of [6] + +### 5.6.3 NETCONF Session Termination + +For O-DU NETCONF Session Termination functionality description, please refer to clause 6.1.9 of [6]. + +### 5.6.4 NETCONF Session Establishment + +The O-DU NETCONF Session Establishment functionality description, please refer to clause 6.1.8 of [6]. + +--- + +## 6 Heartbeat Management Services + +### 6.1 Heartbeat Notification + +Heartbeat Notification for O-DU is aligned with [6], clause 6.6.1 Heartbeat Notification. + +### 6.2 Heartbeat Control + +Heartbeat Control for O-DU is aligned with [6], clause 6.6.2 Heartbeat Control. + +--- + +## 7 PNF Software Management + +### 7.1 Introduction + +The PNF Software Management Services specified in O1 Interface Specification [6] is adapted to the software management for O-DU. Please refer clause 6.8 of [6]. This clause describes the behaviour of O-DU in the software management process between the SMO, O-DU and O-RU. + +### 7.2 O-DU Software Management + +Please refer to clause 6.8 of [6]. + +### 7.3 O-RU Software Management + +#### 7.3.1 Hierarchical Model + +##### 7.3.1.1 Preparation + +##### 7.3.1.1.1 Aggregated YANG data model + +O-DU provides the software inventory information of each connected O-RU to the SMO by o-ran-agg-software-management.yang that has a mount point. To mount the software-inventory instance in o-ran-software-management.yang defined in [6] under the mount point, O-DU shall prepare the ietf-yang-schema-mount.yang with appropriate configuration as shown in the following example. + +**Example:** configuration of the ietf-yang-schema-mount.yang in xml format for software management. + +``` +<schema-mounts> + <namespace> + <prefix>o-ran-swm</prefix> + <uri>urn:o-ran:software-management:1.0</uri> + </namespace> + <mount-point> + <module>o-ran-agg-software-management</module> + <label>swm-root</label> + <config>>false</config> + <inline></inline> + </mount-point> +</schema-mounts> +``` + +In this case, building the data tree such as following image, which is not created or validated by a tool (e.g. pyang), is expected and the SMO will retrieve it from O-DU. + +``` +module: o-ran-aggregation-base + +--rw aggregated-o-ru + +--ro recovered-ru-instance-ids* [ru-instance-id] + | +--ro ru-instance-id ru-ref + +--rw aggregation* [ru-instance] + +--rw ru-instance -> /aggregated-o-ru/recovered-ru-instance-ids/ru-instance-id + +--rw or-agg-swm:software-management-model + +--mp swm-root + +--ro software-inventory + +--ro software-slot* [name] + +--ro name string + +--ro status enumeration + +--ro active? boolean + +--ro running? boolean + +--ro access? enumeration + +--ro product-code? -> /hw:hardware/component/o-ran-hw:product-code + +--ro vendor-code? string + +--ro build-id? string + +--ro build-name? string + +--ro build-version? string + +--ro files* [name] + +--ro name string + +--ro version? string + +--ro local-path string + +--ro integrity? enumeration +``` + +## 7.3.1.2 Software inventory + +### 7.3.1.2.1 Description + +The SMO retrieves the software inventory information of O-RU by using the aggregated yang data model. + +### 7.3.1.2.2 Procedures + +#### Precondition: + +- O-DU has the software inventory information of connected O-RUs, which is retrieved in startup with O-RU. + +![Sequence diagram for Software Inventory showing SMO (PNF Software MnS Consumer) and O-DU (PNF Software MnS Provider) interacting. SMO sends [1] Establish NETCONF Session, [2] NETCONF <rpc> <get> <filter>, [3] NETCONF <rpc-reply> <data>, and [4] Terminate NETCONF Session to O-DU. A callout box indicates 'Retrieve Software Inventory Information of O-RU'.](98f5e58f6d743b4c325f53747a793da5_img.jpg) + +**Software Inventory** + +``` + +sequenceDiagram + participant SMO as SMO +(PNF Software MnS Consumer) + participant ODU as O-DU +(PNF Software MnS Provider) + participant ORU as O-RU + + SMO->>ODU: [1] Establish NETCONF Session + ODU->>SMO: [2] NETCONF <rpc> <get> <filter> + ODU-->>SMO: [3] NETCONF <rpc-reply> <data> + SMO->>ODU: [4] Terminate NETCONF Session + + Note over ODU, ORU: Retrieve Software Inventory Information of O-RU + +``` + +Sequence diagram for Software Inventory showing SMO (PNF Software MnS Consumer) and O-DU (PNF Software MnS Provider) interacting. SMO sends [1] Establish NETCONF Session, [2] NETCONF , [3] NETCONF , and [4] Terminate NETCONF Session to O-DU. A callout box indicates 'Retrieve Software Inventory Information of O-RU'. + +**Figure 7-1: Software Inventory** + +1. SMO establishes NETCONF session with O-DU. +2. O-DU receives NETCONF <rpc><get><filter> from SMO where software aggregated model is indicated to retrieve information of software slot of O-RU. +3. O-DU returns requested data in NETCONF <rpc-reply> response. +4. SMO terminates NETCONF session with O-DU. + +### 7.3.1.3 Software Download + +#### 7.3.1.3.1 Description + +The SMO triggers the software download to O-RU by sending software download rpc defined in [6] with ru-instance-id which identifies a target O-RU. After software download for O-RU, O-DU performs the software install to O-RU according to [2]. + +#### 7.3.1.3.2 Procedures + +![Sequence diagram for Software Download showing interactions between SMO, O-DU, Software Server, and O-RU. The diagram includes steps for establishing a NETCONF session, validating a request, and two alternative cases for downloading software: direct (O-DU to O-RU) and indirect (O-DU to Software Server to O-RU).](fdd184b6875e8ad70b43c4c5c120ff89_img.jpg) + +**Software Download** + +``` + +sequenceDiagram + participant SMO as SMO +(PNF Software MnS Consumer) + participant ODU as O-DU +(PNF Software MnS Provider) + participant SS as Software Server + participant ORU as O-RU + + SMO->>ODU: [1] Establish NETCONF Session + SMO->>ODU: NETCONF <rpc><software-download> +[2] <remote-file-path><softwarePackage> +<ru-instance-id> + Note over ODU: Validate Request + ODU-->>SMO: [3] NETCONF <rpc-reply><software-download-status> + SMO->>ODU: [4] Terminate NETCONF Session + + alt [direct case] + ODU->>ORU: [5] <rpc><software-download> + ORU-->>ODU: [6] <rpc-reply><software-download> + ORU->>SS: [7] <<SFTP>> file download + else [indirect case] + ODU->>SS: [8] <<FTPeS or SFTP>> file download + Note over ODU: manifest file check + ODU->>ORU: [9] <rpc><software-download> + ORU-->>ODU: [10] <rpc-reply><software-download> + ORU->>SS: [11] <<SFTP>> file download + end + + ORU->>ODU: [12] <notification><download-event><status> + ODU->>ORU: [13] <rpc><software-install><slot-name> + ORU-->>ODU: [14] <rpc-reply><software-install> + ORU->>ODU: [15] <notification><install-event><status> + ODU->>SMO: [16] <<HTTP/TLS>> downloadFile Event + +``` + +Sequence diagram for Software Download showing interactions between SMO, O-DU, Software Server, and O-RU. The diagram includes steps for establishing a NETCONF session, validating a request, and two alternative cases for downloading software: direct (O-DU to O-RU) and indirect (O-DU to Software Server to O-RU). + +Figure 7-2: Software Download + +1. SMO establishes NETCONF session with O-DU. +2. SMO sends NETCONF <rpc><software-download><remote-file-path><softwarePackage> with ru-instance-id to trigger a download of the software and to identify the target O-RU. + - a. O-DU validates the request. +3. O-DU returns NETCONF <rpc-reply><software-download-status>. +4. SMO terminates NETCONF session with O-DU. +- Alternative 1: O-RU directly downloads the software package from software server + 5. O-DU sends <rpc><software-download> toward O-RU with remote-file-path. + 6. O-RU returns <rpc-reply><software-download>. + 7. O-RU downloads the software package. +- Alternative 2: O-RU indirectly downloads the software package from software server + 8. O-DU downloads software package of O-RU from software server and temporarily stores in the storage on itself. + + +NOTE: storing SW package in O-DU may be removed after step 14. + + - b. O-DU decides whether download is needed or not by comparing manifest file and information of software slot. + 9. O-DU sends <rpc><software-download> toward O-RU with remote-file-path. + 10. O-RU returns <rpc-reply><software-download>. + 11. O-RU downloads the software package. + 12. O-RU sends <notification><download-event> to notify the result of download process. + +13. O-DU sends <rpc><software-install> to perform the software install for O-RU. O-DU selects an install slot based on [2]. +14. O-RU returns <rpc-reply><software-install>. +15. O-RU sends <notification><install-event> to notify the result of install process. +16. When download operation is completed, O-DU sends download-event NETCONF downloadFile notification to SMO with the final status of the download (success or the reason for failure). + +### 7.3.1.4 SW activate + +#### 7.3.1.4.1 Description + +When O-DU receives NETCONF <rpc><software-activate><softwarePackage> with ru-instance-id from the SMO, O-DU executes the software activation mechanism to O-RU indicated by ru-instance-id. + +#### 7.3.1.4.2 Procedures + +![Sequence diagram for Software Activate procedure involving SMO, O-DU, and O-RU.](7b55cea959bce23c4565284e6a7b6283_img.jpg) + +**Software Activate** + +``` + +sequenceDiagram + participant SMO as SMO +(PNF Software MnS Consumer) + participant ODU as O-DU +(PNF Software MnS Provider) + participant ORU as O-RU + + SMO->>ODU: [1] Establish NETCONF Session + ODU->>SMO: [2] NETCONF <rpc><software-activate><softwarePackage> +<ru-instance-id> + Note over ODU: Validate request + ODU-->>SMO: [3] NETCONF <rpc-reply> <status> + SMO->>ODU: [4] Terminate NETCONF Session + ODU->>ORU: [5] NETCONF <rpc> <software-activation><slot-name> + ORU-->>ODU: [6] NETCONF <rpc-reply> <software-activation><status> + ORU->>ODU: [7] NETCONF <notification><activation-event> + ODU->>ORU: [8] NETCONF <rpc> <reset> + ORU-->>ODU: [9] NETCONF <rpc-reply> <reset> + Note over ORU: Reset + ODU->>SMO: [10] <<HTTP/TLS>> softwareActivate Event + +``` + +The diagram illustrates the 'Software Activate' procedure. It involves three main entities: SMO (PNF Software MnS Consumer), O-DU (PNF Software MnS Provider), and O-RU. The process begins with the SMO establishing a NETCONF session with the O-DU. The SMO then sends a NETCONF <rpc><software-activate><softwarePackage> message with the <ru-instance-id> to the O-DU. The O-DU validates this request and returns a NETCONF <rpc-reply> <status> to the SMO. The SMO then terminates the NETCONF session with the O-DU. The O-DU then sends a NETCONF <rpc> <software-activation><slot-name> message to the O-RU. The O-RU returns a NETCONF <rpc-reply> <software-activation><status> to the O-DU. The O-RU then sends a NETCONF <notification><activation-event> to the O-DU. The O-DU then sends a NETCONF <rpc> <reset> message to the O-RU. The O-RU returns a NETCONF <rpc-reply> <reset> to the O-DU. Finally, the O-DU sends a <<HTTP/TLS>> softwareActivate Event to the SMO. A 'Reset' note is placed on the O-RU lifeline after the reset message. + +Sequence diagram for Software Activate procedure involving SMO, O-DU, and O-RU. + +**Figure 7-3: Software Activate** + +1. SMO establishes NETCONF session with O-DU. +2. SMO sends NETCONF <rpc><software-activate><softwarePackage> with ru-instance-id to trigger an activation of the software slot on O-RU. + - a. O-DU validates the request. +3. O-DU returns status to the SMO in the NETCONF <rpc-reply> response. +4. SMO terminates NETCONF session with O-DU. +5. O-DU sends <rpc><software-activation> to activate the software slot on O-RU. The most recently used slot to install is selected. +6. O-RU returns status into <rpc-reply>. +7. O-DU receives <notification><activation-event>. + +8. O-DU sends <rpc><reset> toward O-RU to apply the newly installed and activated software. +9. O-RU returns <rpc-reply>. + - a. O-RU starts reset process. +10. When O-DU retrieves software inventory information of all reset O-RU in the startup, O-DU sends a softwareActivate notification to SMO with the final status of the software activate and O-RU reset results. + +## 7.3.2 Hybrid Model + +In the hybrid architecture for O-RU, this clause is not applicable as O-DU is not responsible for the SW management of O-RU. In such case, the SMO performs the software management of O-DU by [6], and the software management of O-RU by O-RAN WG4 Management Plane Specification [2]. The SMO may perform the software management of O-RU by O1 Interface Specification [6] if O-RU supports [6] for its management. + +# 8 Performance Assurance Management + +## 8.1 Performance Data File Reporting + +Performance Data File Reporting function for O-DU is aligned with O1 Interface Specification [6] except following part. + +### **O-RU performance counters measured at O-RU:** + +In the hierarchical architecture of O-RAN WG4 Management Plane Specification [2], O-DU as NETCONF client will control the performance measurement of O-RU as NETCONF server. The information to be collected in O-RU is also controlled by SMO via O-DU by [2]. They are defined in Annex A.14. + +The measured result file created by O-RU will be periodically uploaded to O-DU's internal storage aligned with [2] and O-DU will handle it by Performance Data File Reporting function aligned with O1 interface spec [6]. As the alternative way, the measured result file created by O-RU will be forwarded to the FTP server configured by O-DU. For the latter case, Performance Assurance MnS Consumer shall provide the remote-SFTP-upload-path and its credential to O-RU that can upload the PM data file directly. + +### 8.1.1 PM File Content + +The Measurement Type and definitions for performance counters are described in both clause 6.3 of O1 interface specification [6] and Annex A of this specification. All measurements are optional and can be selected based on service deployment. + +### 8.1.2 PM File Naming + +PM file naming is specified in [6] clause 6.3.1.7. + +### 8.1.3 PM File XML Format + +PM file XML format is specified in [6] clause 6.3.1.8. + +## 8.2 Performance Data Streaming + +Performance Data Streaming for O-DU is aligned with [6] + +## 8.3 Performance Assurance Control + +Performance Assurance Control for "O1 interface for O-DU" is aligned with [6]. + +In addition to the parameters defined in Measurement Control, the following two parameters are additionally defined for O1 interface spec. + +- **pm-count-list-drb**: indicates the QoS group specific to performance assurance control for **qci-index**. Each entry contains **qci-index** [0...255] and corresponding **pm-count-group** [0...17]. The multiple entries with different **qci-index** can map to same **pm-count-group** to combine the measurement result for them. Value 0 for **pm-count-group** means that there is no need to collect measurement for the **qci-index**. +- **pm-count-list-srb**: indicates the QoS group specific to performance assurance control for **srb-index**. Each entry contains **srb-index** [SRB1, SRB2, SRB3] and corresponding **pm-count-group** [0, 18...20]. Value 0 for **pm-count-group** means that there is no need to collect measurement for the **srb-index**. + +NOTE: pm-count-group [1..20] corresponds to PmCountGroup number #0 to 19. + +## 8.3.1 Performance Assurance Control for O-RU performance counters + +### O-RU performance counters measured at O-DU: + +In the hierarchical architecture of O-RAN WG4 Management Plane Specification [2], O-DU as NETCONF client will measure the performance counters defined in Annex A.13. The measurementTypes and gPs for O-RU performance counters measured at O-DU are defined in aggregation model. A part of yang tree structure related to this subclause is shown as follows. + +``` +module: o-ran-aggregation-base + +--rw aggregated-o-ru + +--ro recovered-ru-instance-ids* [ru-instance-id] + | +--ro ru-instance-id ru-ref + | +--rw aggregation* [ru-instance] + | +--rw ru-instance -> /aggregated-o-ru/recovered-ru-instance-ids/ru-instance-id + | +--ro or-agg-pm:measurementsList* [idx] + | +--ro or-agg-pm:idx uint32 + | +--ro or-agg-pm:measurementTypes* string + | +--ro or-agg-pm:gPs* uint32 +``` + +On the other hand, the measurement control such as selecting the counters to be reported is performed using 3GPP SA5 data model in the same way as other measurement counters for O-DU. + +### O-RU performance counters measured at O-RU: + +The measurement activation and de-activation of O-RU are controlled by SMO by aggregation model according to [2] clause 10.2. The details of configuration method of aggregation model are described in clause 12. + +## 9 Fault Supervision Management + +### 9.1 General + +Fault Supervision Management allows a managed element to provide asynchronous Fault notification to the authorized manager of the managed element. O-DU should have a capability to send fault notifications and corresponding authorized manager should have a capability to receive and handle the fault notifications for managed element. + +The requirement of Fault Supervision Management is based on the Fault Supervision Management Services of O1 interface specification [6] that contains 3GPP TS 28.545 [7] such as the requirement of fault notification and control. This clause describes the fault supervision management for O-DU specific aspects. + +General architecture of Fault Supervision Management is aligned with the Fault Supervision Management Services of O1 interface specification [6]. + +## 9.2 Definition of the Operations for Fault Events + +O-DU Fault Supervision Management is specified in clause 6.2.2 of O1 interface specification [6]. Fault Supervision Management subscription is specified in clause 6.1.7 of O1 interface specification [6]. + +## 9.3 Definition of Notifications as Fault Events + +O-DU as for Fault Supervision Data Report service producer notifies the JSON encoded asynchronous notifications to Fault Supervision MnS Consumer using REST/HTTPS. All O1 fault notification types are specified in clause 6.2.1.4 of O1 interface specification [6]. + +## 9.4 Message Format for Fault Events + +An O-RAN fault notification format is specified in clause 6.2.1.4 of O1 interface specification [6]. + +## 9.5 O-RU Alarms Management by O-DU in Hierarchical Model + +In hierarchical model, O-DU is responsible for managing AlarmRecords in the AlarmList, including O-DU alarms and O-RU alarms. O-DU receives NETCONF based alarm notification from the O-RU, converts NETCONF based alarm notification to O-RAN fault notification, updates AlarmRecords and delivers it to SMO. O-DU alarms and O-RU alarms may have the same alarm-id, they are distinguished using nfcNamingCode in the VES common event header. + +![Sequence diagram illustrating the operation to merge O-RU Alarms by O-DU. The diagram shows three entities: O-RU, O-DU, and SMO. 1. O-RU detects a change of state in one of the alarms in the active-alarm-list corresponding to the filter settings established in the subscription. 2. O-RU sends a notification to O-DU: [1] <notification> [1] <alarm-notif>..</alarm-notif> </notification>. 3. O-DU converts NETCONF based alarm notification to O-RAN fault notification, updates alarm records. 4. O-DU sends the O-RU alarm event delivery using O-RAN fault notification to SMO: [2] O-RU alarm event delivery using O-RAN fault notification.](f52a2ca8e18673298690274c44fdbe15_img.jpg) + +``` + +sequenceDiagram + participant ORU as O-RU + participant ODU as O-DU + participant SMO as SMO + + Note over ORU: RU detects a change of state in one of the alarms in the active-alarm-list corresponding to the filter settings established in the subscription. + ORU->>ODU: [1] <notification> [1] <alarm-notif>..</alarm-notif> </notification> + Note over ODU: O-DU converts NETCONF based alarm notification to O-RAN fault notification, updates alarm records. + ODU->>SMO: [2] O-RU alarm event delivery using O-RAN fault notification + +``` + +Sequence diagram illustrating the operation to merge O-RU Alarms by O-DU. The diagram shows three entities: O-RU, O-DU, and SMO. 1. O-RU detects a change of state in one of the alarms in the active-alarm-list corresponding to the filter settings established in the subscription. 2. O-RU sends a notification to O-DU: [1] [1] .. . 3. O-DU converts NETCONF based alarm notification to O-RAN fault notification, updates alarm records. 4. O-DU sends the O-RU alarm event delivery using O-RAN fault notification to SMO: [2] O-RU alarm event delivery using O-RAN fault notification. + +Figure 9-1: Operation to merge O-RU Alarms by O-DU + +The field mapping between NETCONF based alarm notification and VES based Fault3gpp notification is as in the following table: + +1 + +| O-RU NETCONF based fault notification | SQ | ONAP VES common event header field name | ONAP VES event parameter name in 'fault3gppFields' | SQ | Remark | +|---------------------------------------|----|-----------------------------------------|----------------------------------------------------|----|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| fault-id | M | - | alarmId | O | | +| fault-source | M | - | additionalInformation | O | | +| affected-objects - name | M | - | additionalInformation | O | | +| fault-severity | M | - | perceivedSeverity | M | If is-cleared is TRUE, perceivedSeverity shall be updated with "Cleared".<br>If is-cleared is FALSE, notificationType shall be updated with fault-severity. | +| is-cleared | M | - | | | | +| fault-text | O | - | additionalInformation | O | | +| event-time | M | startEpochMicrosec<br>lastEpochMicrosec | - | M | If is-cleared is TRUE, event-time shall be mapped to lastEpochMicrosec.<br>If is-cleared is FALSE, event-time shall be mapped to both startEpochMicrosec and lastEpochMicrosec. | + +**Table 1: Mapping of O-RU NETCONF based fault notification to ONAP VES in 'fault3gppFields'** + +2 + +3 + +4 + +## 10 File Management + +5 + +### 10.1 Introduction + +6 + +This clause illustrates File Management between the O-DU and the SMO/OAM. The File Management Service is applied to manage file transfer for different types of data file such as Bulk CM file, Call and UE trace file, Performance Measurement result file, etc. The following file management use cases are supported for the O-DU: + +7 + +8 + +9 + +- List available files +- Transfer file +- Download file +- File ready notification + +10 + +11 + +12 + +13 + +The detailed description of the use cases including file management operations and procedures as well as sequence diagram can be found in the O1 Interface Specification [6], clause 6.5. + +14 + +15 + +This clause shall describe the handling of files that are stored in the O-DU which are generated by the O-DU itself or transferred from another server like O-RU(s). One scenario would be that files stored in the O-DU file repository are transferred from the O-RU or from some other file servers. The files handling between O-DU and O-RU are defined in the O-RAN WG4 Management Plane Specification [2]. + +16 + +17 + +18 + +19 + +The data files that are stored in the O-DU shall follow clause 8.1 of this specification. + +20 + +## 10.2 File Structure + +The file system structure for the O-DU is defined as for file management procedures defined in the rest of this clause. If the O-DU's physical file structure differs from the logical file structure defined below, the O-DU shall perform the mapping of related files into defined structure. + +The O-DU shall support the standardized folders for files generated by the O-DU itself and files transferred from O-RUs. The following standardized folders are defined: + +- › O-RAN/O-DU/PM/ for performance data files +- › O-RAN/O-DU/CM/ for configuration files (except inventory), +- › O-RAN/O-DU/NL/ for notification log file +- › O-RAN/O-DU/CT/ for call trace files +- › O-RAN/O-DU/OT/ for other files +- › O-RAN/O-DU/O-RU<RC>/ for files from O-RU which shall follow [2] logical file structure. The RC parameter is a running count, starting with the value of "1", and shall be appended only if the filename is not unique, i.e. more than one file is generated, and all other parameters of the file name are identical. +- › The O-DU may additionally support vendor defined folders which are out of scope of this specification. + +## 10.3 Notification notifyFileReady + +The file ready notification is applied when the management data files have been prepared in the O-DU. The O-DU will send notification using notifyFileReady VES event to subscribed SMO/OAM, in order to notify the availability of the file(s) as defined in [6]. + +The following input parameters are provided by the file ready notification (see also 3GPP TS 32.342 [10]): + +| | | +|------------------|-------------------------------------------------------------------------------------| +| objectClass | Notification header – see 3GPP TS 32.302 [11]. It shall carry the FTIRP class name. | +| objectInstance | Notification header - see 3GPP TS 32.302 [11]. It shall carry the DN of the FTIRP. | +| notificationId | Notification header - see 3GPP TS 32.302 [11]. | +| eventTime | Notification header - see 3GPP TS 32.302 [11]. | +| systemDN | Notification header - see 3GPP TS 32.302 [11]. | +| notificationType | Notification header – see 3GPP TS 32.302 [11]. | +| fileInfoList | It specifies the information of the available file. | +| additionalText | It carries vendor-specific semantics not defined in the present document. | + +**Table 2: Parameters list for Notification notifyFileReady** + +When a file is available, the O-DU sends a notifyFileReady notification to the SMO using HTTP/TLS as defined in [6]. + +![Sequence diagram showing File Ready Notification between SMO and O-DU. The O-DU sends a 'New file is available' notification to the SMO via an HTTP/TLS message.](634e55b0032a3c5fed25f70e1d55cf02_img.jpg) + +**File Ready Notification** + +``` + +sequenceDiagram + participant SMO as SMO (File Management Service Consumer) + participant ODU as O-DU (File Management Service Provider) + Note over ODU: New file is available + ODU->>SMO: [1] HTTP/TLS<notifyFileReady> + +``` + +Sequence diagram showing File Ready Notification between SMO and O-DU. The O-DU sends a 'New file is available' notification to the SMO via an HTTP/TLS message. + +**Figure 10-1: File Ready Notification** + +## 10.4 File Management Operation: listAvailableFiles + +This listAvailableFiles operation for the SMO/OAM is applied to obtain the available file list with files location and type from the O-DU by reading the AvailableFileList IOC as specified in [10]. SMO/OAM may read the O-RU available files which are already stored in the O-DU and can be represented with AvailableFileList IOC as specified in [10]. Detailed procedure can be found in clause 6.5.2 of [6]. + +## 10.5 File Management Operation: transferFile + +The Transfer File Service provides the capability for the SMO/OAM to transfer files from or to the O-DU. The SMO/OAM may perform this action as a result of a FileReady notification from the O-DU informing SMO/OAM that a file is now available to transfer. In any case, the file transfer is performed using a secure file transfer protocol (SFTP or FTPeS) from or to the location provided by the O-DU. The SMO/OAM triggers file transfer operation to the O-DU. Detailed procedure can be found in clause 6.5.3 of [6]. + +## 10.6 File Management Operation: downloadFile + +The Download File Service provides the capability for the SMO/OAM to request the O-DU to download the file(s) when the SMO/OAM has a file that needs to be downloaded. In any case, the file download is performed using a secure file transfer protocol (SFTP or FTPeS) from the location provided by the SMO/OAM. The O-DU replies to the SMO/OAM with the result of the download procedure. Detailed procedure can be found in clause 6.5.4 of [6]. + +# 11 Synchronization Aspects + +## 11.1 Introduction + +This clause provides the Management Plane's interactions with various aspects of the time synchronization of the O-DU. In general, the O-DU is responsible for managing its synchronization status, to select one or more synchronization input source(s) in the LLS-C1/LLS-C2/LLS-C3 deployments and act as synchronization master in LLS-C1/LLS-C2 deployments. + +Synchronization deployment options are defined in the [9]. + +O-RU synchronization is defined by WG4, refer for details to the [2]. + +Refer to ITU-T recommendations [i.6], [i.4], [i.2], [i.3] for details of synchronization. + +Prerequisite is that the O-DU synchronization parameters have been provisioned to the O-DU; + +- Before O-DU can start to synchronize its internal clock by external timing source. +- Before O-DU begins its function as master clock. + +Following clauses contain main parameters required for O-DU when it is receiving synchronization from external timing source. All parameters are defined in o-ran-synchronization.yang, which shall be read together with this document. + +## 11.2 Synchronization + +### 11.2.1 Synchronization status + +The read-only sync-state indicates O-DU synchronization status: + +- **LOCKED:** O-DU clock timing is phase-locked to a reference timing signal. Refer also to [i.4] definition. +- **HOLDOVER:** O-DU clock has lost its controlling reference input and is using stored data, acquired while in locked operation, to control its output. Refer also to [i.4] definition. + +Note: HOLDOVER state is optional. + +- **FREERUN:** O-DU clock has lost its controlling reference input and the output frequency accuracy is outside of required accuracy. Refer also to [i.4] definition. + +When state of O-DU synchronization changes, O-DU shall send notifyMOIAttributeValueChange notification VES event about change. + +O-DU shall raise appropriate alarm in case of state change to HOLDOVER or FREERUN. O-DU shall cancel alarm when state changes back to LOCKED. + +O-DU shall update information which timing source(s) O-DU is using to synchronize its own clock. O-DU shall update this to ptp-status, synce-status and gnss-status containers described in following clauses. + +![State transition diagram for synchronization states: sync_FREERUN, sync_LOCKED, and sync_HOLDOVER.](c3755c78c49568b39ea4cafe4a311066_img.jpg) + +``` + +graph TD + Start(( )) -- startup --> sync_FREERUN + sync_FREERUN -- "external sync established" --> sync_LOCKED + sync_LOCKED -- "external sync lost (without HOLDOVER mode)" --> sync_FREERUN + sync_LOCKED -- "external sync lost" --> sync_HOLDOVER + sync_HOLDOVER -- "external sync restored" --> sync_LOCKED + sync_HOLDOVER -- "holdover mode expired" --> sync_FREERUN + style sync_HOLDOVER fill:#ccc + +``` + +The diagram illustrates the allowed state transitions for synchronization. It starts with a 'startup' event leading to the 'sync\_FREERUN' state. From 'sync\_FREERUN', an 'external sync established' event transitions to 'sync\_LOCKED'. From 'sync\_LOCKED', an 'external sync lost (without HOLDOVER mode)' event transitions back to 'sync\_FREERUN'. From 'sync\_LOCKED', an 'external sync lost' event transitions to 'sync\_HOLDOVER'. From 'sync\_HOLDOVER', an 'external sync restored' event transitions back to 'sync\_LOCKED'. Finally, from 'sync\_HOLDOVER', a 'holdover mode expired' event transitions back to 'sync\_FREERUN'. The 'sync\_HOLDOVER' state is shaded grey, indicating it is optional. + +State transition diagram for synchronization states: sync\_FREERUN, sync\_LOCKED, and sync\_HOLDOVER. + +**Figure 11-1: Allowed sync state transitions** + +Note: HOLDOVER mode is optional and depends on internal O-DU design. + +## 11.2.2 Synchronization capabilities + +The read-only container sync-capability tells which timing source type(s) O-DU is capable to support. + +## 11.2.3 Synchronization configuration + +The container sync-config contains: + +Configurable list sync-priority-config, which is priority order list to control O-DU to select timing source(s). + +Timing source types: + +- GNSS +- PTP +- SYNCE + +Because SyncE only provides a frequency signal, it can only be used in combination with another timing source providing phase synchronization. Specific configurable parameter sync-enabled is used to control SyncE usage. + +## 11.2.4 PTP configuration + +The container ptp-config contains: + +- needed parameters for G.8275.1 and G.8275.2 configuration. + +- domain-number. This indicates Domain Number for PTP announce messages. +- accepted-clock-classes. This is a list of PTP acceptable Clock Classes +- delay-asymmetry. The parameter defines static phase error in the recovered PTP timing signal to be compensated at the device +- local-priority. The parameter defines local priority. + +PTP profile selection of G.8275.1 or G.8275.2 + +The container g-8275-1-config contains: + +- multicast-mac-address. The parameter defines the destination MAC address, used by the O-DU in the egress PTP messages. Allowed values: + - FORWARDABLE (means that PTP shall use 01-1B-19-00-00-00 destination MAC address) + - NONFORWARDABLE (means that PTP shall use 01-80-C2-00-00-0E destination MAC address) + +The container g-8275-2-config contains: + +- list master-ip-configuration. Defines list of ip configuration of devices acting as ptp signal source. +- ip-address. The parameter defines master IP address. + +## 11.2.5 PTP status + +Container ptp-status contains: + +- reporting-period, which defines minimum time between ptp-status VES notification reports sent by O-DU. +- sync-source-status, which contains status of PTP as timing source: + - IN\_USE - Indicates that this source is the current master clock, i.e. the clock, which the clock, controlled by the device, is synchronized to. + - USABLE - Indicates that this source is an alternate master, which the clock, controlled by the device, can potentially synchronize to, i.e. clock class and priority, announced by the master clock is lower, compared to those of the clock, controlled by the device, and the clock class is accepted. + - NOT\_USABLE - Indicates that this source is an alternate master, which the clock, controlled by the device, has an operational connection to, but the class or priority of the master clock is higher or equal to those of the clock, controlled by the device, or the clock class is not accepted. + - NOT\_IN\_USE - Indicates that this source is an alternate master, which the clock controlled by the device, has no operational connection to. +- clock-class, which contains clock class of the clock, controlled by the O-DU +- clock-identity, which is received from the PTP source +- sources, which contains a list of PTP sources per local-port-number. +- steps-removed, which value is received PTP Announce message stepsRemoved attribute +1. +- other attributes from the PTP Announce messages. + +## 11.2.6 SyncE configuration + +The container sync-config contains configuration parameters for the SyncE: + +- acceptance-list-of-ssm, which defines SyncE SSM values acceptable. +- ssm-timeout, maximum duration in seconds for which the actual SSM value may be different than configured values. + +## 11.2.7 SyncE status + +Container synce-status contains: + +- reporting-period, which defines minimum time between synce-status VES notification reports sent by O-DU. + - sync-source-status, which contains status of SyncE as timing source: + - IN\_USE - Indicates that this source is the current master clock, i.e. the clock, which the clock, controlled by the device, is synchronized to. + - USABLE - Indicates that this source is an alternate master, which the clock, controlled by the device, can potentially synchronize to, i.e. when the clock quality of the primary SyncE signal (SSM value) is lower, when compared to the alternate master, controlled by the device, and the SSM value is accepted. + - NOT\_USABLE - Indicates that this source is an alternate master, which the clock, controlled by the device, has an operational connection to, but the SSM value is not accepted (i.e clock quality is not in the acceptable range). + - NOT\_IN\_USE - Indicates that this source is an alternate SyncE clock, which the clock controlled by the device, has no operational connection to. +- Note, master identity is not generally available unless ESMC is in use. +- sources, which contains list of SyncE sources per local-port-number, as reference to source MAC address, from which the SyncE signal is received. + +## 11.2.8 GNSS Configuration + +If O-DU Yang if-feature GNSS is true and O-DU is connected to GNSS RX (e.g. having some specific non radio interface, which is an example of local PRTC), then container gnss-config contains configuration parameters for the GNSS: + +- enable, which defines if GNSS receiver shall be enabled or not +- satellite-constellation-list, which defines list of constellations to be used to acquire synchronization: + - GLONASS + - GALILEO + - BEIDOU + - GPS + +## 11.2.9 GNSS Status + +If O-DU supports GNSS feature, then container gnss-status contains GNSS status parameters: + +- reporting-period, which defines minimum time between gnss-status VES notification reports sent by O-DU. +- sync-source-status, which contains status of GNSS as timing source: + - IN\_USE - Indicates that this source is the current master clock, i.e. the clock, which the clock, controlled by the device, is synchronized to. + +- USABLE - Indicates that this source is an alternate master, which the clock, controlled by the device, can potentially synchronize to, i.e. clock class and priority, announced by the master clock is lower, compared to those of the clock, controlled by the device, and the SSM value is accepted. + - NOT\_USABLE - Indicates that this source is an alternate master, which the clock, controlled by the device, has an operational connection to, but the class or priority of the master clock is higher or equal to those of the clock, controlled by the device, or the SSM value is not accepted. + - NOT\_IN\_USE - Indicates that this source is an alternate master, which the clock controlled by the device, has no operational connection to. +- gnss-sync-status: +- SYNCHRONIZED - Indicates that GNSS functionality is synchronized. + - ACQUIRING-SYNC - Indicates that GNSS functionality is acquiring sync. + - ANTENNA-DISCONNECTED - Indicates that GNSS functionality has its antenna disconnected. + - BOOTING - Indicates that GNSS functionality is booting. + - ANTENNA-SHORT-CIRCUIT - Indicates that GNSS functionality has an antenna short circuit. + +## 11.3 Synchronization master + +### 11.3.1 Introduction + +O-DU acts as synchronization master for fronthaul in LLS-C1/LLS-C2 deployments. Synchronization deployment options are defined in the [9]. + +Prerequisite for O-DU to act as synchronization master is that O-DU's sync-state is LOCKED. + +Container sync-master-capabilities contains information of O-DU capability to act as a synchronization master and needed configuration parameters. + +Following clauses contain main parameters required for O-DU acting as synchronization master. All parameters are defined in o-ran-synchronization.yang, which shall be read together with this document. + +### 11.3.2 Synchronization master capabilities + +Container sync-master-capabilities contains information of O-DU capability to act as a synchronization master: + +- ptp-sync-master-capabilities contains: + +- ptp-sync-master-supported: + - TRUE – O-DU can serve as PTP synchronization master. + - FALSE – O-DU cannot serve as PTP synchronization master. + +- synce-sync-master-capabilities contains: + +- synce-sync-master-supported: + - TRUE – O-DU can serve as SyncE synchronization master. + - FALSE – O-DU cannot serve as SyncE synchronization master. + +Note: [9] considers only SyncE + PTP. + +### 11.3.3 Synchronization master configuration + +Container sync-master-configuration contains configuration parameters for O-DU to act as a synchronization master. + +- ptp-master-configuration contains configuration for PTP master: + +- ptp-master-enabled-local-port-numbers. This is reference to portNumber of ExternalEthernetPort to identify the port, where the PTP is provided. +- domain-number. This parameter indicates Domain Number for PTP announce messages. +- multicast-mac-address. This parameter indicates Ethernet MAC address to be used as destination address (forwardable, nonforwardable) +- priority2. This parameter reflects value of the priority2 attribute in PTP Announce messages. + +- sync-master-configuration contains configuration for SyncE master: + +- sync-master-enabled-local-port-numbers. This is reference to portNumber of ExternalEthernetPort to identify the port, where the SyncE is provided. + +Note! If configuration change is applied during O-DU run time, i.e. transmission to air is ongoing, configuration change may cause service interruption. + +### 11.3.4 Master PTP status + +Container ptp-master-status contains + +- reporting-period, which defines minimum time between ptp-master-status VES notification reports sent by O-DU. +- ptp-status containing PTP status and PTP message attributes. Refer to [i.2], [i.5] and o-ran-synchronization.yang. In case O-DU is synchronized using PTP, O-DU will forward PTP message attributes received from the sync-source to master port. In case O-DU is synchronized from GNSS, O-DU shall compute locally PTP message attributes to be sent on the PTP master port. + +## 11.4 O-DU and O-RU synchronization relation with cell and carrier activation / in-activation + +### 11.4.1 Cell and carrier activation + +O-DU sync-state and O-RU sync-state shall be LOCKED (or HOLDOVER) before O-DU is allowed to send gNB-DU Configuration Update to CU, because it contains *Served NR Cells To Add/Modify/Delete IE* indicating cells which O-CU can activate. + +When O-DU receives GNB-CU CONFIGURATION UPDATE including *Cells to be Activated List Item IE* from CU, O-DU shall check that O-DU sync-state and O-RU sync-state are LOCKED (or HOLDOVER) before O-DU configures to O-RU the value of the parameter “active” at tx-array-carrier element / rx-array-carrier element to “ACTIVE” for the carriers serving the cell(s) requested to be activated. + +If O-DU sync-state is not LOCKED (and not HOLDOVER), then O-DU shall not activate any cells from *Cells to be Activated List Item IE*. O-DU shall report back to CU *Cells failed to be activated list IE*. + +If O-RU(s) sync-state is not LOCKED (and not HOLDOVER), then O-DU shall not activate carriers related to *Cells to be Activated List Item IE*, to those O-RU(s) which sync-state is not LOCKED (and not HOLDOVER). O-DU shall report back to CU *Cells failed to be activated list IE* for cells that O-DU did not activate carrier(s) to O-RU(s). + +## 11.4.2 Cell and carrier in-activation + +When O-DU sync-state transits to FREERUN state, O-DU shall disable all carriers in all O-RUs and report to CU in gNB-DU Configuration update *Cells Status IE* all O-DU cells as inactive. + +When O-DU receives notification from O-RU that O-RU sync-state transit to FREERUN, O-DU shall disable all carriers in that O-RU and report to CU in gNB-DU Configuration update *Cells Status IE* all affected cells as inactive. + +Refer to the [9] clause 9.4.1.3 and [2] clause 15.3.3 for more details. + +# 12 Provisioning Management + +## 12.1 Introduction + +The requirement of Provisioning Management is described in clause 6.1 Provisioning Management Services of O1 Interface Specification [6]. This clause describes the Provisioning Management for O-DU specific aspects in addition to [6]. + +There are 2 models to be considered for configuration of O-DU: + +### A) Hierarchical model + +- SMO configures O-DU with all instances which are necessary for O-DU and each O-RU under O-DU. These instances are based on 3GPP SA5 data model specified in 3GPP TS 28.541 [8] and O-RAN WG4 Management Plane Specification [2] YANG data model. + +Note: This spec focuses on the model as the first step. + +### B) Hybrid model + +- SMO configures O-DU with all instances which are necessary for O-DU and some O-RAN WG4 Management Plane Specification [2] data model instances which are necessary for each O-RU under O-DU to be configured by O-DU (not by SMO). In such case, SMO configures O-RUs directly using remaining [2] data model instances which don't need to be configured via O-DU. + +Note: The categorize of [2] data model instances (either via O-DU or not) is for further study, and this spec will reflect the agreement in future release. + +## 12.2 Configuration for Hierarchical Model + +### 12.2.1 Configuration Step + +Configuration steps for hierarchical model are following: + +#### **Step1: SMO configures the instances to O-DU** + +Regarding the data model configured from SMO, there are 4 types: + +#### **1. 3GPP SA5 data model** + +Following modules are necessary since these are related to O-DU. See TS 28.541 [8] + +- \_3gpp-common-managed-element.yang +- \_3gpp-nr-nrm-gnbdfunction.yang +- \_3gpp-nr-nrm-nrcelldu.yang +- \_3gpp-nr-nrm-ep.yang +- \_3gpp-nr-nrm-nrsectorcarrier.yang +- \_3gpp-nr-nrm-bwp.yang +- \_3gpp-nr-nrm-beam.yang +- \_3gpp-nr-nrm-commonbeamformingfunction.yang + +## 2. O-RAN WG5 modified model based on 3GPP SA5 + +These are added prefix “o-ran-“ to the module name of 3GPP SA5. + +Note: Additional instances should be expected to be proposed to 3GPP for having alignment between 3GPP and O-RAN WG5. Study on the model will be included in the next version of this specification. + +## 3. O-RAN WG4 data model + +O-RAN WG4 data model instances which cannot be mapped from SA5 data model and cannot be created by O-DU’s internal logic, needs to be set from SMO to O-DU by aggregation model based on O-RAN WG4 data model. Which parameters needs to be configured from SMO is described in Annex D + +## 4. O-RAN WG5 original data model + +O-RAN WG5 introduces original data model in order to configure instances which are related to fronthaul operation at O-DU side (such as O-DU transmission/reception window). 3GPP does not assume non integrated O-DU, so O-RAN WG5 introduces original model for supporting fronthaul operations. + +Note: These modules are not expected to be proposed to 3GPP since these are for fronthaul management operation and 3GPP does not assume fronthaul management. This version includes o-ran-wg5-delay-management.yang. Whether other modules are necessary or not will be studied in the next version of this specification. + +### Step2: O-DU configures to O-RU + +O-DU configures to O-RU by several ways: + +1. Mapping 3GPP SA5 parameters to WG4 parameters. +2. Creating WG4 parameters by internal logic +3. Configuring based on aggregation model + +These categories are specified in Annex D. + +## 12.2.2 Aggregation model for configuration to O-RU via SMO + +In order to configure WG4 data model to O-RU via O-DU from SMO, aggregation model which has a mount point is used. The following is an example of o-ran-uplane-conf.yang: + +Aggregation model: o-ran-agg-uplane-conf.yang is prepared + +``` + +module o-ran-agg-uplane-conf { + yang-version 1.1; + namespace "urn:o-ran:agg-uplane-conf:1.0"; + prefix "o-ran-agg-uplane-conf"; + + import o-ran-aggregation-base { + prefix "agg"; + } + + import ietf-yang-schema-mount { + prefix "yangmnt"; + } + + organization "O-RAN Alliance"; + + contact + "www.o-ran.org"; + + description + "This module defines the augmentation of the base aggregation module to configure o-ran-uplane-conf.yang + instances to O-RUs. + ==omitted== + augment "/agg:aggregated-o-ru/agg:aggregation" { + container uplane-conf-model { + yangmnt:mount-point "uplane-conf-root" { + description + "Root for o-ran-uplane-conf.yang model supported per O-RU instance"; + } + } + } +} + +``` + +SMO configures ietf-yang-schema-mount.yang in xml format for uplane configuration. + +``` + +<schema-mounts> + <namespace> + <prefix> o-ran-uplane-conf</prefix> + <uri> urn:o-ran:uplane-conf:1.0</uri> + </namespace> + <mount-point> + <module> o-ran-agg-uplane-conf</module> + <label>uplane-conf-root</label> + <config>true</config> + <inline></inline> + </mount-point> +</schema-mounts> + +``` + +SMO configures O-DU for each O-RU by using o-ran-aggregation-base.yang as below. **ru-instance** indicates O-RU to be configured, with provided aggregated yang module. + +``` + +<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0"> + <edit-config> + <config> + <aggregated-o-ru xmlns="urn:o-ran:agg-uplane-conf:1.0"> + <aggregation> + <ru-instance>(mfg-name)_(model-name)_(serial-num)</ru-instance> + <uplane-conf-model xmlns="urn:o-ran:agg-uplane-conf:1.0"> + <uplane-conf-root> + <user-plane-configuration xmlns="urn:o-ran:uplane-conf:1.0"> + <low-level-tx-links> + <name>low-level-tx-links1</name> + ... + </user-plane-configuration> + </uplane-conf-root> + </uplane-conf-model> + </aggregation> + </aggregated-o-ru> + </config> + </edit-config> +</rpc> + +``` + +**id** in NRCellIDU should be equal to **ru-instance-id** of O-RU which the NRCellIDU belongs to in order to link between NRCellIDU and O-RU. + +After configuring from SMO, O-DU configures to each O-RU based on configured instances from SMO. O-DU distinguishes which O-RU to be configured by ru-instance at above xml from SMO. + +## 12.3 Configuration for Hybrid model + +This clause will be described in the next version of this specification. + +## 12.4 Cell Activation + +### 12.4.1 Hierarchical Model + +After cell configuration and carrier configuration which are described at clause 12.2, SMO activates cells as Figure 9 + +![Sequence diagram illustrating the Cell activation procedure (Figure 12-1). The diagram shows interactions between O-RU, O-DU, O-CU, and SMO. The process is divided into two main sections: a 'par' block for initial configuration and an 'F1 Startup step' block for F1 setup and configuration updates. The 'par' block includes steps [1] Cell configuration, [2] Carrier configuration, [3] <sync-status>LOCKED</sync-status>, and [4] <sync-state>LOCKED</sync-state>. The 'F1 Startup step' block includes steps [7] F1 setup request, [8] F1 setup response, [9] gNB-CU configuration update, and [10] gNB-CU configuration update ACK. Step [5] <operationalState>ENABLED</operationalState> and step [6] <administrativeState>UNLOCKED</administrativeState> are also shown. Step [11] <active>ACTIVE</active> is shown as part of an <rpc> <edit-config> block.](0927fa56b72b1a36eb4d95414dfc28e7_img.jpg) + +``` + +sequenceDiagram + participant O-RU + participant O-DU + participant O-CU + participant SMO + + par + O-DU->>O-RU: [1] Cell configuration + O-DU->>O-RU: [2] Carrier configuration + O-DU->>O-DU: [3] <sync-status>LOCKED</sync-status> + O-DU->>O-CU: [4] <sync-state>LOCKED</sync-state> + and + O-DU->>O-DU: [5] <operationalState>ENABLED</operationalState> + O-DU->>O-DU: [6] <administrativeState>UNLOCKED</administrativeState> + end + + O-DU->>O-CU: [7] F1 setup request + O-CU-->>O-DU: [8] F1 setup response + O-DU->>O-CU: [9] gNB-CU configuration update + O-CU-->>O-DU: [10] gNB-CU configuration update ACK + + O-DU->>O-RU: [11] <rpc> <edit-config> <active>ACTIVE</active> </edit-config> </rpc> + +``` + +Sequence diagram illustrating the Cell activation procedure (Figure 12-1). The diagram shows interactions between O-RU, O-DU, O-CU, and SMO. The process is divided into two main sections: a 'par' block for initial configuration and an 'F1 Startup step' block for F1 setup and configuration updates. The 'par' block includes steps [1] Cell configuration, [2] Carrier configuration, [3] LOCKED, and [4] LOCKED. The 'F1 Startup step' block includes steps [7] F1 setup request, [8] F1 setup response, [9] gNB-CU configuration update, and [10] gNB-CU configuration update ACK. Step [5] ENABLED and step [6] UNLOCKED are also shown. Step [11] ACTIVE is shown as part of an block. + +Figure 12-1: Cell activation procedure + +### 12.4.2 Hybrid Model + +This clause will be described at the next version. + +Note: This subclause will follow O-RAN WG4 O1 Alignment WI output. + +## 12.5 Notification aspect in hierarchical model + +### 12.5.1 Introduction + +There are 2 topics to be specified in this specification on notification aspect: + +- Subscribing for the O-RU notification from the SMO + - Subscription for the O-RU notification specified in WG4 M-Plane specification [2] shall be done by the O-DU and corresponding parameters values shall be stored in the aggregated model of the O-RU. The SMO shall subscribe for parameters of interest changes from the O-RU aggregated model. +- Forwarding the notification from O-RU via O-DU + - Some of the O-RU notification specified in WG4 M-Plane specification [2] should be forwarded to the SMO via the O-DU. In such case the SMO will receive notifications from the O-DU, after subscribing to the parameters of interest from the O-RU aggregated model. + +Note: Some of the notifications are not necessary to be forwarded to the SMO via the O-DU since it is enough to be noticed by the O-DU. In such case it is not needed for the SMO to make subscription to those parameters in the O-RU aggregated model. + +Note: In Hybrid model, no additional description is necessary in this spec since O-RU can send notification to SMO directly (no need to send notification via O-DU). + +### 12.5.2 Subscribing for O-RU notification from SMO + +The O-DU is responsible for representing parameters of the O-RU using aggregated YANG model. The SMO is responsible of subscribing to the parameters of interest from aggregated model using subscription mechanism described in O1 Interface specification [6] clause 6.1.7 Subscription Control. + +### 12.5.3 Forwarding the notification from O-RU via O-DU + +Once the SMO is subscribed to the parameters of interest as described in clause 12.5.2 of this specification, the SMO will receive notification about each value change of parameter(s) in the O-DU. + +![Sequence diagram for Figure 12-2: Notification to the SMO preceded by the O-RU notification. The diagram shows three lifelines: SMO, O-DU, and O-RU. A yellow note box at the top states 'SMO is already subscribed to O-DU'. An arrow labeled 'notification' goes from O-RU to O-DU. A text block on the O-DU lifeline says 'Change of aggregated model parameters for the O-RU'. A self-loop arrow is on the O-DU lifeline. A yellow note box below states 'Parameter of interest of SMO has chaged'. An arrow labeled 'notification' goes from O-DU to SMO.](c720b32051a7be1cab60363c909d0d1e_img.jpg) + +``` + +sequenceDiagram + participant SMO + participant O-DU + participant O-RU + Note over SMO,O-DU: SMO is already subscribed to O-DU + O-RU->>O-DU: notification + Note over O-DU: Change of aggregated model parameters for the O-RU + O-DU->>O-DU: + Note over SMO,O-DU: Parameter of interest of SMO has chaged + O-DU->>SMO: notification + +``` + +Sequence diagram for Figure 12-2: Notification to the SMO preceded by the O-RU notification. The diagram shows three lifelines: SMO, O-DU, and O-RU. A yellow note box at the top states 'SMO is already subscribed to O-DU'. An arrow labeled 'notification' goes from O-RU to O-DU. A text block on the O-DU lifeline says 'Change of aggregated model parameters for the O-RU'. A self-loop arrow is on the O-DU lifeline. A yellow note box below states 'Parameter of interest of SMO has chaged'. An arrow labeled 'notification' goes from O-DU to SMO. + +Figure 12-2: Notification to the SMO preceded by the O-RU notification + +![Sequence diagram for Figure 12-3: Notification to the SMO preceded by the O-DU <get> operation. The diagram shows three lifelines: SMO, O-DU, and O-RU. A yellow note box at the top states 'SMO is already subscribed to O-DU'. On the O-DU lifeline, there is a sequence of messages: '<rpc>', '<get>', '</get>', and '<rpc>'. An arrow goes from O-DU to O-RU. On the O-RU lifeline, there is a sequence of messages: '<rpc-reply>', '<data>', '...', '</data>', and '<rpc-reply>'. An arrow goes from O-RU to O-DU. A text block on the O-DU lifeline says 'Change of aggregated model parameters for the O-RU'. A self-loop arrow is on the O-DU lifeline. A yellow note box below states 'Parameter of interest of SMO has chaged'. An arrow labeled 'notification' goes from O-DU to SMO.](3040f61099850ff4f7801b4b69a142c7_img.jpg) + +``` + +sequenceDiagram + participant SMO + participant O-DU + participant O-RU + Note over SMO,O-DU: SMO is already subscribed to O-DU + Note over O-DU: <rpc> +<get> +</get> +<rpc> + O-DU->>O-RU: + Note over O-RU: <rpc-reply> +<data> +... +</data> +<rpc-reply> + O-RU->>O-DU: + Note over O-DU: Change of aggregated model parameters for the O-RU + O-DU->>O-DU: + Note over SMO,O-DU: Parameter of interest of SMO has chaged + O-DU->>SMO: notification + +``` + +Sequence diagram for Figure 12-3: Notification to the SMO preceded by the O-DU operation. The diagram shows three lifelines: SMO, O-DU, and O-RU. A yellow note box at the top states 'SMO is already subscribed to O-DU'. On the O-DU lifeline, there is a sequence of messages: '', '', '', and ''. An arrow goes from O-DU to O-RU. On the O-RU lifeline, there is a sequence of messages: '', '', '...', '', and ''. An arrow goes from O-RU to O-DU. A text block on the O-DU lifeline says 'Change of aggregated model parameters for the O-RU'. A self-loop arrow is on the O-DU lifeline. A yellow note box below states 'Parameter of interest of SMO has chaged'. An arrow labeled 'notification' goes from O-DU to SMO. + +Figure 12-3: Notification to the SMO preceded by the O-DU <get> operation + +# 13 Fronthaul Delay Management Support + +O-RAN WG4 [2] specifies delay management between O-DU and O-RU, where transmission of data over fronthaul is governed by O-DU transmission/reception window and O-RU transmission/reception window. O-RU transmission/reception window is decided by O-RU itself, and the relevant procedures and data models are specified in WG4 spec [2]. This clause addresses how O-DU transmission/reception window can be determined and the relevant procedures and data models. + +O-DU may support the following alternatives: + +## A) Not Configured by O1 + +- O-DU determines O-DU transmission/reception window. How O-DU determines the window is up to O-DU, it may be hardcoded value at O-DU, or calculated from O-RU transmission/reception window and FH delay based on O-RAN WG4 Management Plane Specification [2]. + +Note: WG4 IOT profile describes O-DU transmission/reception window values. O-DU transmission/reception window can be hardcoded based on these values. + +- There is no impact to this specification, since O-DU transmission/reception window is determined at O-DU. + +## B) Configured by O1 + +- SMO configures the O-DU transmission/reception window by O1. The SMO configured parameters should be taken by the O-DU as the maximum or minimum allowed values for the respective transmission/reception window parameters. Having the SMO configure maximum or minimum allowed values instead of the exact value, provides necessary flexibility for the O-DU implementation. SMO may take into account O-RU reported window and FH delay to determine O-DU transmission/reception window. +- There is impact to this specification, where the details are described below. + +Note: This version focuses on hierarchical model. Next version will include hybrid model since this scheme can be extended to hybrid model. + +## Pre-condition + +- Connection is established between SMO - O-DU / O-DU - O-RU + +## Post-condition + +- Delay management between O-DU and O-RU is operational + +Steps of Fronthaul delay management support are as follows: + +1. SMO sends <rpc><get><window-determine-capability> to O-DU for getting the capability of O-DU +2. O-DU replies the rpc with O-DU's capability. There are 3 capabilities: + +**Not-Configured:** O-DU transmission/reception window can be determined by O-DU + +**Configured:** O-DU transmission/reception window can be determined by configured value from SMO + +**Both:** O-DU has both capabilities, **Not-Configured** and **Configured** + +3. SMO decides the method how O-DU transmission/reception window is determined from capability supported by O-DU + 4. SMO sends <rpc><edit-config><**window-determine-method**> based on the decision of step3. + 5. In parallel with step1,2,3, O-DU gets O-RU transmission/reception window based on O-RAN WG4 specification [2] + 6. If SMO directs **Not-Configured** as **window-determine-method** to O-DU at step4, O-DU transmission/reception window is determined by O-DU. How O-DU determines the window is up to O-DU, it may be hardcoded value at O-DU, or calculated from O-RU transmission/reception window and FH delay based on O-RAN WG4 CUS spec [9]. If SMO has pre-configured FH delay, SMO sends it in rpc **window-determine-method** for O-DU to calculate O-DU transmission/reception window. + 7. If SMO directs **Configured** as **window-determine-method** to O-DU at step4, + 1. SMO sends <rpc><get><**o-ru-window**> and/or <**measured-transport-delay**> to O-DU as necessary (SMO may have such information apriori and may not need to get them from O-DU). + 2. SMO determines O-DU transmission/reception window taking into account the following WG4 instances: + - FH delay (pre-defined or measured): + - **t12-min, t12-max,** + - **t34-min, t-34max** + - O-RU transmission/reception window: + - **t2a-min-up, t2a-max-up** + - **t2a-min-cp-dl, t2a-max-cp-dl** + - **tcp-adv-dl** + - **ta3-min, ta3-max** + - **t2a-min-cp-ul, t2a-max-cp-ul** +- SMO determines the following parameters for O-DU transmission/reception window: +- **maximum-t1a-max-up:** + - the maximum allowed value of T1a\_max\_up + - **minimum-t1a-min-up:** + - the minimum allowed value of T1a\_min\_up + - **maximum-t1a-max-cp-dl:** + - the maximum allowed value of T1a\_max\_cp\_dl + - **minimum-t1a-min-cp-dl:** + - the minimum allowed value of T1a\_min\_cp\_dl + - **maximum-t1a-max-cp-ul:** + - the maximum allowed value of T1a\_max\_cp\_ul + - **minimum-t1a-min-cp-ul:** + - the minimum allowed value of T1a\_min\_cp\_ul + - **maximum-ta4-max:** + +➤ the minimum allowed value of Ta4\_max + +- **minimum-ta4-min:** + +➤ the maximum allowed value of Ta4\_min + +Note: The above maximum or minimum allowed values for the respective O-DU transmission/reception window parameters that the SMO determines should satisfy the relations specified in 4.4.3 U-Plane/ C-Plane Timing in O-RAN WG4 CUS-Plane Specification [9]. + +3. SMO sends <rpc><edit-config><**o-du-window**> with determined maximum or minimum allowed values for the respective O-DU transmission/reception window parameters at the previous step. + +4. O-DU sets O-DU transmission/reception window based on **o-du-window** from SMO. + +8. If O-RU has the capability to set O-RU transmission/reception window adaptively as specified at 7.8 O-RU Adaptive Delay Capability in O-RAN WG4 M-Plane spec, O-DU sends O-DU transmission/reception window and FH delay to O-RU. O-RU may set O-RU transmission/reception window adaptively based on O-DU transmission/reception window and FH delay. + +9. Delay management between O-DU and O-RU is operational + +![Sequence diagram showing the Delay Management Configuration Procedure between SMO, O-DU, and O-RU. The process includes M-Plane connection establishment, window determination, and adaptive delay capability adaptation.](33201ebc7872a74abf078c083697a6b9_img.jpg) + +``` + +sequenceDiagram + participant SMO + participant O-DU + participant O-RU + + Note over SMO: opt +FH delay is pre-defined + Note over SMO, O-DU: M-Plane connection establishment + Note over O-DU, O-RU: M-Plane connection establishment + + par + SMO->>O-DU: <rpc> +<get> +<window-determine-capability>NOT-CONFIGURED</window-determine-capability> +<pre-configured-transport-delay>..</pre-configured-transport-delay> +</get> +</rpc> + O-DU-->>SMO: <rpc-reply> + and + Note over SMO: Decide the method +how O-DU transmission/reception window +is determined from window-determine-capability + and + O-RU-->>O-DU: Retrieval of +O-RU transmission/reception window + end + + alt [Not-Configured] + SMO->>O-DU: <rpc> +<edit-config> +<window-determine-method>NOT-CONFIGURED</window-determine-method>> +</edit-config> +</rpc> + O-DU-->>SMO: <rpc-reply> + Note over O-DU: O-DU transmission/reception window +is determined by O-DU + else [Configured] + SMO->>O-DU: <rpc> +<get> +<window-determine-capability>CONFIGURED</window-determine-capability> +</get> +</rpc> + O-DU-->>SMO: <rpc-reply> + opt [SMO gets information as necessary] + SMO->>O-DU: <rpc> +<get> +<o-ru-window>..</o-ru-window> +<measured-transport-delay>..</measured-transport-delay> +</get> +</rpc> + O-DU-->>SMO: <rpc-reply> + end + Note over SMO: Determine the maximum or minimum allowed values +for the respective O-DU transmission/reception window parameters + SMO->>O-DU: <rpc> +<edit-config> +<o-ru-window>..</o-ru-window> +</edit-config> +</rpc> + O-DU-->>SMO: <rpc-reply> + Note over O-DU: O-DU sets O-DU transmission/reception window +based on o-du-window from SMO + end + + opt [O-RU window adaptation] + Note over O-RU: Adapting O-RU transmission/reception window procedure +as specified at 4.8 O-RU Adaptive Delay Capability in O-RAN WG4 M-Plane spec + end + + Note over O-DU, O-RU: Delay management is operational + +``` + +Sequence diagram showing the Delay Management Configuration Procedure between SMO, O-DU, and O-RU. The process includes M-Plane connection establishment, window determination, and adaptive delay capability adaptation. + +Figure 13-1: Delay Management Configuration Procedure + +--- + +## 14 Trace Management Services + +### 14.1 Introduction + +Trace Management Service for O-DU is aligned with O1 Interface Specification [6], clause 6.4. + +### 14.2 Call Trace + +Call Trace for for O-DU is aligned with O1 Interface Specification [6], clause 6.4.1. + +### 14.3 Minimization of Drive Testing (MDT) + +Minimization of Drive Testing for O-DU is aligned with O1 Interface Specification [6], clause 6.4.2. + +### 14.4 Radio Link Failure (RLF) + +Radio Link Failure for O-DU is aligned with O1 Interface Specification [6], clause 6.4.3. + +### 14.5 RRC Connection Establishment Failure (RCEF) + +RRC Connection Establishment Failure for O-DU is aligned with O1 Interface Specification [6], clause 6.4.4. + +### 14.6 Trace Control + +Trace Control for O-DU is aligned with O1 Interface Specification [6], clause 6.4.5. + +### 14.7 Streaming Trace + +Streaming Trace for O-DU is aligned with O1 Interface Specification [6], clause 6.4.6. + +--- + +## 15 Shared O-RU + +### 15.1 Introduction + +A Shared O-RU deployment allows one or more operators to connect their O-DUs to an O-RU and share its resources. + +An O-DU should simultaneously support connections to non-Shared O-RUs, Multi O-DU O-RUs and/or Multi-Operator O-RUs, dependent on which Shared O-RU features the O-DU supports. + +Refer to [2] for more details of Shared O-RU. + +## 15.2 Single Operator Shared O-RU + +### 15.2.1 O-DU(s) roles + +In Single Operator Shared O-RU deployment, O-DUs do not have specific access privilege roles as in Multi-Operator Shared O-RU. O-DUs use the same access control groups as in non-Shared O-RU. + +In hierarchical deployment, O-DUs all use the same access control group “sudo” toward the Multi O-DU O-RU. One O-DU acts as primary O-DU responsible for configuring general OAM related configuration, supervision per O-DU, NETCONF call home and managing general OAM functions. + +Refer to clause 12 and [2] clause 6.5 for further details. + +### 15.2.2 Configuring O-RU + +#### 15.2.2.1 Configuring O-RU general OAM related configuration + +In hierarchical deployment, it is recommended that SMO configures general OAM related configuration for each Multi O-DU O-RU using O1 toward only one sharing O-DU (primary). That O-DU then consequently uses the configuration data to configure the Multi O-DU O-RU over its fronthaul interface. If SMO configures the same Multi O-DU O-RU through more than one sharing O-DU, it is recommended that SMO validates outside of the O-DUs that the configuration is aligned in all the sharing O-DUs to avoid configuration discrepancy. How validation is done is out of the scope of the present document. + +NOTE: O-RU does not check which O-DU(s) is configuring it, nor does it validate if e.g., same parameter is configured to different allowed values by O-DUs. + +In hybrid deployment, it is recommended that SMO directly configures all general OAM related configuration for each Multi O-DU O-RU over its Fronthaul M-plane interface. + +Refer to clause 12 for further details. + +#### 15.2.2.2 Managing O-RU general OAM related functions + +In hierarchical deployment, it is recommended that SMO manages Multi O-DU O-RU general OAM functions using O1 toward only one sharing O-DU (primary), for example: software management, file Management, synchronization aspects, antenna line devices, operational aspects of external IO, O-RU connectors, beamforming configuration update, user account provisioning. If SMO manages general OAM functions for the same Multi O-DU O-RU through more than one sharing O-DU, it is recommended that SMO co-ordinates the O-DUs that the management is aligned in all of the sharing O-DUs to avoid discrepancy. How validation is done is out of the scope of the present document. + +In hybrid deployment, it is recommended that SMO directly manages all Multi O-DU O-RU general OAM functions for each Multi O-DU O-RU over its Fronthaul M-plane interface. + +O-DUs may manage other O-RU functions independently e.g., NETCONF connection establishment, performance management, fault management, static configuration for PRACH and SRS. + +Refer to clause 12 and [2] clauses 8, 12, 13, 14.4, 14.5, 14.6, 15.4 for further details. + +#### 15.2.2.3 Configuring carrier configuration + +SMO shall configure only the cells that the O-DU serves and their corresponding carriers over O1 towards that O-DU. The O-DU shall then consequently configure the corresponding tx/rx-array-carriers on the Multi O-DU O-RUs over their fronthaul interfaces. + +#### 15.2.2.4 Carrier state management + +An O-DU shall only activate or deactivate the tx/rx-array-carriers on the Shared O-RU that belongs to the cells that the O-DU serves. + +When an O-DU receive a notification from a Shared O-RU indicating tx/rx-array-carrier state change, the O-DU shall treat the notification in the same way as for a non-shared O-RU, i.e., O-DU shall ignore the notifications that do not relate to the O-DU cell's NRSectorCarriers. + +#### 15.2.3 Supervision Monitoring per O-DU + +In hierarchical deployment, SMO may configure SecondaryODuInfo including attribute *supervisionPerODu* over O1 on the primary O-DU. The primary O-DU shall then consequently configure Shared Resource Operator O-DU supervision on each Shared O-RU. + +In hybrid deployment, SMO instead may configure Shared Resource Operator O-DU supervision directly on each Shared O-RU over its Fronthaul M-plane interface. + +Refer to [2] clause 6.7, 19.3.4 for further details. + +#### 15.2.4 NETCONF call home + +In hierarchical deployment, SMO may configure the SecondaryODuInfo including attribute *callHomeClientInfo* over O1 only on the primary O-DU. If *callHomeClientInfo* has been configured, the primary O-DU shall then consequently configure call home addresses on each Shared O-RU. + +In hybrid deployment, SMO instead may configure call home addresses directly on each Shared O-RU over its Fronthaul M-plane interface. + +### 15.3 Multi Operator Shared O-RU + +#### 15.3.1 O-DU(s) roles + +O-DU possible roles towards a Multi Operator Shared O-RU are defined in [2]. O-DU role towards all connected Multi Operator Shared O-RUs is configured over O1 by setting *oDuRoleOfSharedORu* to one of the values: "HOST\_AND\_SRO", "HOST" or "SRO". + +When O-DU role is set to "HOST\_AND\_SRO", the O-DU simultaneously perform the Shared O-RU Host role and the Shared Resource Operator roles towards all connected Multi Operator Shared O-RUs. + +When O-DU role is set to "HOST", the O-DU only performs the Shared O-RU Host role, equaling Neutral Host. That O-DU configures and manages all connected Multi Operator Shared O-RUs but does not have carriers in those O-RUs. + +For each Multi Operator Shared O-RU, at most only one connected O-DU should perform the Shared O-RU Host role. If no connected O-DU performs the Shared O-RU Host role, it is assumed that an SMO performs that role, acting as Neutral Host. However, the scenario in which the Neutral Host is provided by SMO is not considered in this version of the document. + +In a hierarchical deployment containing Multi Operator Shared O-RUs, the O-DU performing the Shared O-RU Host role uses the access control group "sudo" toward all connected Multi Operator Shared O-RUs. The O-DUs performing only the Shared Resource Operator role (i.e., not together with the Shared O-RU Host role) use the access control group "carrier" towards all connected Multi Operator Shared O-RUs. + +In a hybrid deployment containing Multi Operator Shared O-RUs, if an O-DU performs the Shared O-RU Host role, it uses the access control group "hybrid-odu" toward the Multi O-DU O-RU. The O-DUs performing only the Shared + +Resource Operator role (i.e., not together with the Shared O-RU Host role) use the access control group “carrier” towards all connected Multi Operator Shared O-RUs. + +Following sub-clauses define what shall be configured over O1 to O-DU to realize O-DU functions defined in [2]. + +### 15.3.2 Configuring O-RU general OAM related configuration + +In hierarchical deployment, it is recommended that SMO configures O-RU general OAM related configuration over O1 toward only the single Shared O-RU Host O-DU. The Shared O-RU Host O-DU shall then consequently configure general OAM related configuration on the Multi Operator O-RUs over their fronthaul interfaces. + +In hybrid deployment, it is recommended that SMO directly configures general OAM related configuration for each Multi O-DU O-RU over its Fronthaul M-plane interface. + +### 15.3.3 Managing O-RU general OAM related functions + +In hierarchical deployment, it is recommended that SMO manages O-RU general OAM related functions over O1 toward only the single shared O-RU Host O-DU. The Shared O-RU Host O-DU shall then consequently manage general OAM related functions on the Multi Operator O-RUs over their fronthaul interfaces. + +In hybrid deployment, it is recommended that SMO directly manages Multi O-DU O-RU general OAM functions for each Multi O-DU O-RU over its Fronthaul M-plane interface. + +### 15.3.4 NETCONF server user account provisioning for shared resource operators + +In hierarchical deployment, SMO shall configure the SecondaryODuInfo over O1 only on the Shared O-RU Host O-DU. The Shared O-RU Host O-DU shall then consequently configure Shared Resource Operator user accounts with “carrier” access privilege and *sro-id=sharedResourceOperatorId* on the connected Multi Operator O-RUs over their fronthaul interfaces. + +NOTE: Value of each *sharedResourceOperatorId* shall be unique and associated with a particular Shared Resource Operator only. + +In hybrid deployment, SMO instead configures Shared Resource Operator user accounts with “carrier” access privilege and *sro-id=sharedResourceOperatorId* directly on each Multi Operator O-RU over its Fronthaul M-plane interface. + +Refer to [2] clause 19.3.1 for further details. + +### 15.3.5 NETCONF call home + +In hierarchical deployment, SMO may configure the SecondaryODuInfo including attribute *callHomeClientInfo* over O1 only on the Shared O-RU Host O-DU. If *callHomeClientInfo* has been configured, the Shared O-RU Host O-DU shall then consequently configure call home addresses on each Shared O-RU. + +In hybrid deployment, SMO instead may configure call home addresses directly on each Shared O-RU using its Fronthaul M-plane interface. + +Refer to [2] clause 19.3.2 for further details. + +## 15.3.6 Enhanced sro-id based NETCONF access control + +SMO shall configure the attribute *sharedResourceOperatorId* over O1 with a unique value on each Shared Resource Operator O-DU. The Shared Resource Operator O-DU shall then consequently use the value of *sharedResourceOperatorId* for the user account of the NETCONF client with sro-id configured on the Multi Operator Shared O-RUs. + +Refer to [2] clause 19.3.3 for further details. + +## 15.3.7 Supervision Monitoring per O-DU + +In hierarchical deployment, SMO may configure SecondaryODuInfo including attribute *supervisionPerODu* over O1 on the Shared O-RU Host. The Shared O-RU Host shall then consequently configure Shared Resource Operator O-DU supervision on each Shared O-RU. + +In hybrid deployment, SMO instead may configure Shared Resource Operator O-DU supervision directly on each Shared O-RU using its Fronthaul M-plane interface. + +Refer to [2] clause 6.7, 19.3.4 for further details. + +## 15.3.8 Processing element configuration + +Shared O-RU Host O-DU shall use the value of each Shared Resource Operator O-DUs *sharedResourceOperatorId* attribute to configure a particular O-RU's ru-element list entry as being uniquely associated with a particular Shared Resource Operator. Shared O-RU Host O-DU gets *sharedResourceOperatorId* as defined in 13.3.6. + +Refer to [2] clause 19.4.2. + +## 15.3.9 Carrier Partitioning and Configuration in Shared O-RU + +Only Shared O-RU Host O-DU has access privileges over Fronthaul M-plane to create tx/rx-array-carrier configuration in the Shared O-RU. + +NOTE: How Shared Resource Operators agree configuration partitioning is outside the scope of the present document. It is assumed that operators mutually agree partitioning. + +NOTE: How Shared Resource Operators configurations are validated is outside the scope of the present document. It is assumed that operators mutually validate as part of configuration partitioning. + +NOTE: How Shared Resource Operators agree eAxC-IDs partitioning is out of the scope of the present document. It is assumed that operators mutually agree partitioning. + +Refer to clause 12.1 and [2] clause 19.6.1, 19.11. + +## 15.3.10 Notification of configuration updates + +A Shared Resource Operator O-DU may configure subscriptions to receive notifications of modifications to a connected shared O-RU's datastore, according to the defined NETCONF access control privileges for the NETCONF client of that Shared Resource Operator. + +Refer to clause 12 and [2] clause 19.6.2 for further details. + +### 15.3.11 Shared O-RU Reset Co-ordination + +Co-ordination of Shared O-RU reset is outside the scope of the current specification. + +NOTE: It is assumed that operator mutually agree time when Shared O-RU Host O-DU reset Shared O-RU. + +NOTE: It is assumed that SMO(s) disable cell(s) in a controlled manner before Shared O-RU reset. + +Refer to [2] clause 19.10.1 for further details. + +### 15.3.12 Locked administrative state + +Co-ordination of Shared O-RU administrative state change to locked is outside the scope of the current specification. + +NOTE: It is assumed that operators mutually agree time when Shared O-RU Host O-DU change Shared O-RU administrative state to locked. + +NOTE: It is assumed that SMO(s) disable cell(s) in a controlled manner before Shared O-RU state is changed to locked. + +Refer to [2] clause 19.10.2 for further details. + +### 15.3.13 Antenna calibration + +Co-ordination of Shared O-RU antenna calibration timing is outside the scope of the current specification. + +NOTE: It is assumed that operators mutually agree timing for Shared O-RU antenna calibrations. + +Refer to [2] clause 19.10.3 for further details. + +### 15.3.14 Shared O-RU with antenna line devices + +The Shared O-RU Host O-DU is responsible for configuring and controlling antenna line devices. + +NOTE: It is assumed that operators mutually share antenna line devices configuration and co-ordinate antenna line operations e.g., remote electrical tilt. + +Refer to [2] clause 14.4, 19.11.6. + +### 15.3.15 Shared O-RU operation in combination with shared cell + +The Shared O-RU Host O-DU is responsible for configuring shared cell copy and combine parameters on behalf of each Shared Resource Operator O-DU. + +NOTE: How Shared Resource Operators agree Shared Cell configuration of copy and combine is outside the scope of the present document. It is assumed that operators mutually agree partitioning. + +Refer to [2] clause 17, 19.14 for further details. + +## 15.4 Content of Fronthaul M-plane ODU ID + +O-DU uses the value of the attribute *oDuldForSharedORu* as the Fronthaul M-plane odu-id, which is a free text string and can be set to e.g., concatenated gNBId and gNBDUIId. + +## 15.5 Content of Fronthaul M-plane SRO ID + +O-DU uses the value of the attribute *sharedResourceOperatorId* as the Fronthaul M-plane sro-id, which is a free text string and can be set to e.g., PLMN ID. + +# 16 Information Model definition + +## 16.1 Imported and associated information entities + +### 16.1.1 Imported information entities and local labels + +| Label reference | Local label | +|----------------------------------------|---------------| +| 3GPP TS 28.622 [13], IOC, Top | Top | +| 3GPP TS 28.541 [8], IOC, GNBDUFunction | GNBDUFunction | + +### 16.1.2 Associated information entities and local labels + +| Label reference | Local label | +|-----------------------------------|---------------| +| TS 28.541 [8], IOC, GNBDUFunction | GNBDUFunction | + +## 16.2 Class diagrams + +### 16.2.1 Relationships + +![UML Class Diagram showing SharedOruConfiguration containment within GNBDUFunction.](3273e9ecbce230c236a8a62a8e849663_img.jpg) + +``` + +classDiagram + class GNBDUFunction["«InformationObjectClass» GNBDUFunction"] + class SharedOruConfiguration["«InformationObjectClass» SharedOruConfiguration"] + GNBDUFunction "1" *-- "0..1" SharedOruConfiguration : «names» + +``` + +The diagram illustrates the relationship between two information object classes. A yellow note box labeled "defined in 3GPP TS 28.541" points to the **«InformationObjectClass» GNBDUFunction** class. This class is associated with the **«InformationObjectClass» SharedOruConfiguration** class via a directed association. The association has a multiplicity of 1 at the GNBDUFunction end and 0..1 at the SharedOruConfiguration end, with the role name «names» at the SharedOruConfiguration end. + +UML Class Diagram showing SharedOruConfiguration containment within GNBDUFunction. + +Figure 16-1: SharedOruConfiguration containment + +![UML diagram showing containment between GNBDUFunction and NESPolicy for RF Channel Reconfiguration (TRx Control).](d60b5c0c3ff7b33edb8ed179623e60c7_img.jpg) + +The diagram shows two classes: «InformationObjectClass» GNBDUFunction and «InformationObjectClass» NESPolicy. NESPolicy contains a reference to GNBDUFunction. The association is labeled «Names» and has a multiplicity of 1 at the GNBDUFunction end and 0..1 at the NESPolicy end. A yellow callout box points to GNBDUFunction with the text: 'defined in 3GPP TS 28.541 - Inheritance Hierarchy'. The NESPolicy class contains an attribute 'trxCtrlPolicyList'. + +``` + +classDiagram + class GNBDUFunction["«InformationObjectClass» +GNBDUFunction"] + class NESPolicy["«InformationObjectClass» +NESPolicy +trxCtrlPolicyList"] + NESPolicy "0..1" --> "1" GNBDUFunction : «Names» + +``` + +UML diagram showing containment between GNBDUFunction and NESPolicy for RF Channel Reconfiguration (TRx Control). + +**Figure 16-2: RF Channel Reconfiguration (TRx Control) (NESPolicy) containment** + +![UML diagram showing containment between GNBDUFunction and NESPolicy for AdvancedSleepMode.](d0c7d10b7a41fa7d670542bf2b9e9ffb_img.jpg) + +The diagram shows two classes: «InformationObjectClass» GNBDUFunction and «InformationObjectClass» NESPolicy. NESPolicy contains a reference to GNBDUFunction. The association is labeled «Names» and has a multiplicity of 1 at the GNBDUFunction end and 0..1 at the NESPolicy end. A yellow callout box points to GNBDUFunction with the text: 'defined in 3GPP TS 28.541 - Inheritance Hierarchy'. The NESPolicy class contains an attribute 'asmPolicyList'. + +``` + +classDiagram + class GNBDUFunction["«InformationObjectClass» +GNBDUFunction"] + class NESPolicy["«InformationObjectClass» +NESPolicy +asmPolicyList"] + NESPolicy "0..1" --> "1" GNBDUFunction : «Names» + +``` + +UML diagram showing containment between GNBDUFunction and NESPolicy for AdvancedSleepMode. + +**Figure 16-3: AdvancedSleepMode (NESPolicy) containment** + +## 16.2.2 Inheritance + +![UML diagram showing inheritance from SharedOruConfiguration to Top.](9875b0f0c5e94994a43b9024da538203_img.jpg) + +The diagram shows two classes: «InformationObjectClass» Top and «InformationObjectClass» SharedOruConfiguration. SharedOruConfiguration inherits from Top, indicated by a solid line with an open triangle arrowhead. A yellow callout box points to Top with the text: 'defined in 3GPP TS 28.622 clause 4.3.29'. + +``` + +classDiagram + class Top["«InformationObjectClass» +Top"] + class SharedOruConfiguration["«InformationObjectClass» +SharedOruConfiguration"] + SharedOruConfiguration --|> Top + +``` + +UML diagram showing inheritance from SharedOruConfiguration to Top. + +**Figure 16-4: SharedOruConfiguration inheritance** + +![UML class diagram showing NESPolicy inheritance from Top. NESPolicy is an InformationObjectClass with attributes trxCtrlPolicyList and asmPolicyList. Top is also an InformationObjectClass. A note indicates Top is defined in 3GPP TS 28.622 clause 4.3.29. Another note indicates NESPolicy is O-RAN Specific Function (IOC) and attributes specific to O-RAN.](10d7dcfe5c12d3516f426a3651401445_img.jpg) + +``` + +classDiagram + class Top["«InformationObjectClass»\nTop"] + class NESPolicy["«InformationObjectClass»\nNESPolicy"] + NESPolicy --|> Top + NESPolicy -- "trxCtrlPolicyList" + NESPolicy -- "asmPolicyList" + note for Top "defined in 3GPP TS 28.622 clause 4.3.29" + note for NESPolicy "O-RAN Specific Function (IOC) and attributes specific to O-RAN" + +``` + +UML class diagram showing NESPolicy inheritance from Top. NESPolicy is an InformationObjectClass with attributes trxCtrlPolicyList and asmPolicyList. Top is also an InformationObjectClass. A note indicates Top is defined in 3GPP TS 28.622 clause 4.3.29. Another note indicates NESPolicy is O-RAN Specific Function (IOC) and attributes specific to O-RAN. + +Figure 16-5: Network Energy Saving (NESPolicy) inheritance + +## 16.3 Class definitions + +### 16.3.1 SharedOruConfiguration <<IOC>> + +#### 16.3.1.1 Definition + +This Information Object Class (IOC) provides attribute(s) that are needed to configure O-DU to work with Shared O-RU. + +#### 16.3.1.2 Attributes + +The SharedOruConfiguration IOC includes attributes inherited from Top IOC (defined in 3GPP TS 28.622, clause 4.3.29) and contain the following attributes: + +| Attribute name | S | isReadable | isWritable | isInvariant | isNotifiable | +|---------------------------------|----|------------|------------|-------------|--------------| +| <i>oDuRoleOfSharedORu</i> | CM | T | T | F | T | +| <i>sharedResourceOperatorId</i> | CM | T | T | F | T | +| <i>oDuIdForSharedORu</i> | CM | T | T | F | T | +| <i>secondaryODuInfoList</i> | CM | T | T | F | T | + +#### 16.3.1.3 Attribute constraints + +| Name | Definition | +|------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <i>oDuRoleOfSharedORu</i> CM support qualifier | Condition: When O-RU supports Multiple Operator Shared O-RU configuration and O-RU is configured to work in shared O-RU mode, this parameter is mandatory | +| <i>sharedResourceOperatorId</i> CM support qualifier | Condition: When O-RU supports Multiple Operator Shared O-RU configuration and O-RU is configured to work in shared O-RU mode, this parameter is mandatory | +| <i>oDuIdForSharedORu</i> CM support qualifier | Condition: When O-RU supports Multiple Operator Shared O-RU or Shared O-RU Multi O-DU configuration and O-RU is configured to work in shared O-RU mode, this parameter is mandatory | +| <i>secondaryODuInfoList</i> CM support qualifier | Condition: This parameter is mandatory when <i>oDuRoleOfSharedORu</i> is HOST or HOST_AND_SRO in Multi Operator Shared O-RU or primary in Single Operator Shared O-RU. When the role of the O-DU is SRO or secondary, this parameter is not used. | + +#### 16.3.1.4 Notifications + +None + +#### 16.3.1.5 State diagram + +None + +### 16.3.2 SecondaryODuInfo <<data Type>> + +#### 16.3.2.1 Definition + +“This data type provides fields that are needed to configure an O-DU that performs the Shared Resource Operator (SRO) role. The O-DU that has the Shared O-RU Host role configures this data on the Shared O-RUs connected to the SRO O-DU.” + +#### 16.3.2.2 Attributes + +The SecondaryODuInfo data type contains the following fields: + +| Attribute name | S | isReadable | isWritable | isInvariant | isNotifiable | +|---------------------------------|----|------------|------------|-------------|--------------| +| <i>oDulForSharedORu</i> | M | T | T | F | T | +| <i>sharedResourceOperatorId</i> | CM | T | T | F | T | +| <i>accessControlGroup</i> | CM | T | T | F | T | +| <i>supervisionPerODu</i> | O | T | T | F | T | +| <i>callHomeClientInfo</i> | O | T | T | F | T | +| <i>sharedORuList</i> | O | T | T | F | T | + +#### 16.3.2.3 Attribute constraints + +| Name | Definition | +|------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| <i>sharedResourceOperatorId</i> CM support qualifier | Condition: When O-RU supports Multiple Operator Shared O-RU configuration and O-RU is configured to work in shared O-RU mode, this parameter is mandatory | +| <i>accessControlGroup</i> CM support qualifier | Condition: When O-RU supports Multiple Operator Shared O-RU configuration and O-RU is configured to work in shared O-RU mode, this parameter is mandatory | + +#### 16.3.2.4 Notifications + +None + +#### 16.3.2.5 State diagram + +None + +### 16.3.3 CallHomeClientInfo <<data Type>> + +#### 16.3.3.1 Definition + +“This data type provides fields that are needed to configure a call home address for an O-DU that performs the Shared Resource Operator (SRO) role. The O-DU that has the Shared O-RU Host role configures this data on the Shared O-RUs connected to the SRO O-DU.” + +#### 16.3.3.2 Attributes + +The callHomeClientInfo data type contains the following fields: + +| Attribute name | S | isReadable | isWritable | isInvariant | isNotifiable | +|-------------------|---|------------|------------|-------------|--------------| +| <i>host</i> | O | T | T | F | T | +| <i>portNumber</i> | O | T | T | F | T | + +### 16.3.3.3 Attribute constraints + +None + +### 16.3.3.4 Notifications + +None + +### 16.3.3.5 State diagram + +None + +## 16.3.4 NESPolicy <<IOC>> + +### 16.3.4.1 Definition + +This Information Object Class (IOC) is O-RAN specific class and provides attribute(s) that are needed to provide the policy or policies to O-DU to enable or disable the energy saving uses (TRx Control (RF Channel Reconfiguration) and Advanced Sleep Mode) in O-RU. + +### 16.3.4.2 Attributes + +NESPolicy IOC includes attributes inherited from Top IOC (defined in 3GPP TS 28.622, clause 4.3.29) and contains the following attributes that are intended to be used for O-RAN specific NES use cases: + +| Attribute name | S | isReadable | isWritable | isInvariant | isNotifiable | +|--------------------------|---|------------|------------|-------------|--------------| +| <i>trxCtrlPolicyList</i> | O | T | T | F | T | +| <i>asmPolicyList</i> | O | T | T | F | T | + +1 + +## 16.4 Attribute definitions + +| Attribute Name | Documentation and Allowed Values | Properties | +|---------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------| +| <i>oDuRoleOfSharedORu</i> | <p>This attribute defines the role of O-DU. When O-DU role is set to "HOST_AND_SRO", O-DU simultaneously perform the Shared O-RU Host role and the Shared Resource Operator roles.</p> <p>allowedValues: "HOST_AND_SRO", "HOST", "SRO".</p> | <p>type: enum<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: None<br/>isNullable: False</p> | +| <i>sharedResourceOperatorId</i> | <p>This parameter defines Shared Resource Operator ID of O-DUs, which Shared Resource Operator O-DU shall use for the user account of the NETCONF client with sro-id configured. When the role of the O-DU is HOST, this attribute is not used.</p> | <p>type: string<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: None<br/>isNullable: True</p> | +| <i>oDuIdForSharedORu</i> | <p>This parameter defines O-DUs own <i>oduidforsharedoru</i> to be used for fronthaul O-DU ID.</p> | <p>type: string<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: None<br/>isNullable: False</p> | +| <i>accessControlGroup</i> | <p>Defines the Netconf access control group per SRO O-DU, which is then created by the Shared O-RU Host in the Shared O-RUs. If the role for a O-DU already exists, then that role is updated with the new enum "carrier". When the role of the O-DU is SRO, this attribute is not used.</p> | <p>type: string<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: None<br/>isNullable: False</p> | +| <i>supervisionPerODu</i> | <p>Operator may activate O-RU supervision per Shared Resource Operator O-DU by configuring over O1 <i>supervisionperodu</i> to "true", which triggers Shared O-RU Host in Multi Operator Shared O-RU or primary O-DU in Single Operator Shared O-RU to configure <i>odu-id</i> parameter in the per-odu-monitoring over Fronthaul M-plane. When the role of the O-DU is SRO in Multi Operator Shared O-RU or secondary in Single Operator Shared O-RU, this attribute is not used.</p> | <p>type: boolean<br/>multiplicity: 1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: None<br/>isNullable: False</p> | +| <i>secondaryODuInfoList</i> | <p>List containing information about all SRO O-DUs or secondary O-DUs, which shared O-RU Host in Multi Operator Shared O-RU or primary O-DU in Single Operator Shared O-RU shall use to configure the Shared O-RUs included in the <i>sharedORuList</i> field.</p> | <p>type: SecondaryODuInfo<br/>multiplicity: 0..*<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: None<br/>isNullable: False</p> | +| <i>callHomeClientInfo</i> | <p>In Multi Operator Shared O-RU, over O1 is send only to the Shared O-RU Host O-DU <i>callhomeclientinfo</i>, which Shared O-RU Host O-DU shall use to configure in each Shared O-RU multiple call home addresses towards O-DU.</p> <p>In Single Operator Shared O-RU, over O1 is send only to the primary O-DU <i>callhomeclientinfo</i>, which primary O-DU shall use to configure in each Shared O-RU multiple call home addresses towards O-DU.</p> | <p>type: CallHomeClientInfo<br/>multiplicity: 0..1<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: None<br/>isNullable: False</p> | +| <i>sharedORuList</i> | <p>In Multi Operator Shared O-RU, list of Shared O-RU identities connected to the Shared O-RU Host O-DU and Shared Resource Operator O-DU</p> <p>In Single Operator Shared O-RU, list of Shared O-RU identities connected to the primary O-DU and secondary O-DU.</p> | <p>type: string<br/>multiplicity: 0..*<br/>isOrdered: N/A<br/>isUnique: N/A<br/>defaultValue: None<br/>isNullable: False</p> | + +| | | | +|-------------------|----------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------| +| <i>host</i> | Represents an IP address or DNS domain name (see RFC6991). | type: string<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: None<br>isNullable: False | +| <i>portNumber</i> | Represents a 16-bit port number of an Internet transport-layer protocol (see RFC6991). | type: integer<br>multiplicity: 0..1<br>isOrdered: N/A<br>isUnique: N/A<br>defaultValue: None<br>isNullable: False | + +## 17 O-DU behavior for 3GPP conformance testing + +### 17.1 Introduction + +This clause describes O-DU behavior to evaluate O-RU performance based on the 3GPP standardized conformance tests. + +To guarantee the minimum performance of gNB, O-RAN WG5 follows tests definition from [16], [17], and [18]. + +Any points not mentioned in this clause are expected to be in accordance with the corresponding test specifications in [16], [17], and [18]. + +Note: The present version of this specification considers only PNF-deployed O-DU. + +### 17.2 O-DU behavior for O-RU uplink evaluation + +O-DU behavior for uplink tests specified in clauses 7 and 8 in [18] is as follows: + +Step 1: O-DU receives a request, by O1, to conduct a test with the configuration parameters defined in Table 12 of Annex E. + +Step 2: In the test mode, when receiving signals from O-RU for a certain measurement period, O-DU counts measurements shown in Table 12 of Annex E. + +Step 3: O-DU reports the measurements results by O1 as PM counters specified in Annex A. After finishing reporting, O-DU exits the test mode. + +Note: A test of “Receiver spurious emissions” defined in clause 7.6 in [18] is not applicable to the above steps as it is not measured at the O-DU. + +### 17.3 O-DU behavior for O-RU downlink evaluation + +O-DU behavior for downlink tests specified in clause 6 in [18] is as follows: + +Step 1: O-DU receives a request, by O1, to conduct a test with the configuration parameters defined in Table 13 of Annex E. + +Step 2: In the test mode, O-DU generates test data and sends it to O-RU over CU-Plane of the Open Fronthaul interface. After sending test data, the O-DU exits the test mode. + +Note: O-DU doesn’t measure parameters in downlink tests because test results will be collected by the measurement equipment such as a spectrum analyzer. + +## Annex A (informative): Counter definition + +### A.1 NR F1 Interface performance counters + +#### A.1.1 UL PDCP PDUs transmitted via F1-U UL GTP-U tunnel + +##### A.1.1.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.UIPdcpPduTxF1UUl | +| Description | This counter provides the number of the UL PDCP PDUs transmitted via F1-U UL GTP-U tunnel.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the UL PDCP PDU is transmitted via F1 U UL GTP-u tunnel when the QCI or the 5QI of the UL PDCP PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.F1.UIPdcpPduTxF1UUl. <i>Pmgroup</i> where<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +#### A.1.2 UL PDCP PDU volume transmitted via F1-U UL GTP-U tunnel + +##### A.1.2.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.UIPdcpPduVolTxF1UUl | +| Description | This counter provides the UL PDCP PDU volume transmitted via F1-U UL GTP-U tunnel.<br>NOTE: Measurement Object Class, gNBDUFunction, is different to A.1.14.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is accumulated by the volume of UL PDCP PDU whenever the UL PDCP PDU is transmitted via F1 U UL GTP-u tunnel when the QCI or the 5QI of the UL PDCP PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.F1.UIPdcpPduVolTxF1UUl. <i>Pmgroup</i> where<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | + +| | | +|---------|--------------------------------------------------| +| Purpose | Network Operator's Traffic Engineering Community | +|---------|--------------------------------------------------| + +## A.1.3 Maximum UL PDCP PDU volume transmitted via F1-U UL GTP-U tunnel + +### A.1.3.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.MaxUIPdcPduVolTxF1UUl | +| Description | This counter provides the maximum UL PDCP PDU volume transmitted during 1s via F1-U UL GTP-U tunnel.<br>It is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is the maximum value of x when the QCI or the 5QI of the UL PDCP PDU is group of subcounter. <i>Pmgroup</i> . It is assigned with period of 1s by the volume x, if x is bigger than previously counted volume.<br>x is the volume of UL PDCP PDU for every 1 second. x is incremented by the volume of UL PDCP PDU whenever the UL PDCP PDU is transmitted via F1 U UL GTP-u tunnel for a period of 1 second. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.F1.MaxUIPdcPduVolTxF1UUl. <i>Pmgroup</i> where<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.4 Minimum UL PDCP PDU volume transmitted via F1-U UL GTP-U tunnel + +### A.1.4.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.MinUIPdcPduVolTxF1U | +| Description | This counter provides the minimum UL PDCP PDU volume transmitted during 1s via F1-U UL GTP-U tunnel.<br>It is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is the minimum value of x when the QCI or the 5QI of the UL PDCP PDU is group of subcounter. <i>Pmgroup</i> . It is assigned with period of 1s by the volume x, if x is smaller than previously counted volume.<br>x is the volume of UL PDCP PDU for every 1 second. x is incremented by the volume of UL PDCP PDU whenever the UL PDCP PDU is transmitted via F1 U UL GTP-u tunnel for a period of 1 second. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.F1.MinUIPdcPduVolTxF1U. <i>Pmgroup</i> where<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | + +| | | +|------------|--------------------------------------------------| +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.5 DL PDCP PDUs received via F1-U DL GTP-U tunnel + +### A.1.5.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.DlPdcPduRxFlUDl | +| Description | This counter provides the number of the DL PDCP PDUs received via F1-U DL GTP-U tunnel.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the DL PDCP PDU is received via F1 U DL GTP-u tunnel when the QCI or the 5QI of the DL PDCP PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.F1.DlPdcPduRxFlUDl. <i>Pmgroup</i> where<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.6 DL PDCP PDU volume received via F1-U DL GTP-U tunnel + +### A.1.6.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.DlPdcPduVolRxFlUDl | +| Description | This counter provides the DL PDCP PDU volume received via F1-U DL GTP-U tunnel.<br>NOTE: Measurement Object Class, gNBDUFunction, is different to A.1.15.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is accumulated by the volume of DL PDCP PDU whenever the DL PDCP PDU is received via F1 U DL GTP-u tunnel when the QCI or the 5QI of the DL PDCP PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.F1.DlPdcPduVolRxFlUDl. <i>Pmgroup</i> where<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.7 Maximum DL PDCP PDU volume received via F1-U DL GTP-U tunnel + +### A.1.7.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.MaxDIPdcpPduVolRxF1UDl | +| Description | This counter provides the maximum DL PDCP PDU volume received during 1s via F1-U DL GTP-U tunnel.<br>It is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is the maximum value of x when the QCI or the 5QI of the DL PDCP PDU is group of subcounter. <i>Pmgroup</i> . It is assigned with period of 1s by the volume x, if x is bigger than previously counted volume.<br>x is the volume of DL PDCP PDU for every 1 second. x is incremented by the volume of DL PDCP PDU whenever the DL PDCP PDU is received via F1 U DL GTP-u tunnel for a period of 1 second. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.F1.MaxDIPdcpPduVolRxF1UDl. <i>Pmgroup</i> where <i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.8 Minimum DL PDCP PDU volume received via F1-U DL GTP-U tunnel + +### A.1.8.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.MinDIPdcpPduVolRxF1UDl | +| Description | This counter provides the minimum DL PDCP PDU volume received during 1s via F1-U DL GTP-U tunnel.<br>It is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is the minimum value of x when the QCI or the 5QI of the DL PDCP PDU is group of subcounter. <i>Pmgroup</i> . It is assigned with period of 1s by the volume x, if x is smaller than previously counted volume.<br>x is the volume of DL PDCP PDU for every 1 second. x is incremented by the volume of DL PDCP PDU whenever the DL PDCP PDU is received via F1 U DL GTP-u tunnel for a period of 1 second. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.F1.MinDIPdcpPduVolRxF1UDl. <i>Pmgroup</i> where <i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.9 Transmitted F1-C messages + +### A.1.9.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.TxF1CMes | +| Description | This counter provides the number of the transmitted F1-C messages per signal type that is non UE-associated or UE-associated signaling. It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the F1 C-plane message is transmitted per the signal type of the F1 C-plane message: non UE-associated or UE-associated as subcounter. <i>Sigtype</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.F1.TxF1CMes. <i>Sigtype</i> where <i>Sigtype</i> is the signal type:<br>0: non UE-associated<br>1: UE-associated | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.10 Received F1-C messages + +### A.1.10.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.RxF1CMes | +| Description | This counter provides the number of the received F1-C SCTP messages per signal type that is non UE-associated or UE-associated signaling. It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the F1 C-plane message is received per the signal type of the F1 C-plane message: non UE-associated or UE-associated as subcounter. <i>Sigtype</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.F1.RxF1CMes. <i>Sigtype</i> where <i>Sigtype</i> is the signal type:<br>0: non UE-associated<br>1: UE-associated | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.11 DL F1-U packets discarded due to NR U-Plane protocol error + +### A.1.11.1 Performance Counter Table + +| | | +|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.DIF1UDiscardNRUProtocolError | +| Description | This counter provides the number of the DL F1-U packets discarded due to NR U-Plane protocol error. It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The measurement counter is incremented by 1 whenever the DL F1-U plane packet is discarded due to NR U-plane protocol error. | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.F1.DIF1UDiscardNRUProtocolError | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.1.12 DL F1-U packet loss rate + +### A.1.12.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | DRB.F1UPacketLossRateDL | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.3.1.3<br><br><u>O-RAN addition:</u><br>It is optional counter for O-DU.<br>The counter is split into subcounters per S-NSSAI. The counter is recommended when related slice feature is supported. | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.3.1.3 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.3.1.3<br><br><u>O-RAN addition:</u><br>The subcounter per QoS level should be regarded as subcounter per <i>PmGroup</i> , and the subcounter should be calculated per subcounter. <i>Pmgroup</i> . | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.3.1.3 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.3.1.3<br><br><u>O-RAN addition:</u><br>Subcounter OR.DRB.F1UPacketLossRateDL. <i>Pmgroup</i> where <i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | <u>O-RAN Measurement Object Class:</u><br>gNBDUFunction | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.3.1.3 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.3.1.3 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.3.1.3 | + +## A.1.13 DL Packet Drop Rate in gNB-DU + +### A.1.13.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | DRB.RlcPacketDropRateDL | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.3.2.2<br><br><u>O-RAN addition:</u><br>It is optional counter for O-DU.<br>The counter is split into subcounters per S-NSSAI. The counter is recommended when related slice feature is supported. | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.3.2.2 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.3.2.2<br><br><u>O-RAN addition:</u> | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | The subcounter per QoS level should be regarded as subcounter per <i>PmGroup</i> , and the subcounter should be calculated per subcounter. <i>Pmgroup</i> . | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.3.2.2 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.3.2.2<br><br>O-RAN addition:<br>Subcounter OR.DRB.RlcPacketDropRateDl. <i>Pmgroup</i> where <i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.3.2.2 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.3.2.2 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.3.2.2 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.3.2.2 | + +1 + +2 + +## A.1.14 UL PDCP PDU volume transmitted via F1-U UL GTP-U tunnel + +3 + +### A.1.14.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.UIPdcPduCellVolTxF1UU1 | +| Description | This counter provides the UL PDCP PDU volume of the cell transmitted via F1-U UL GTP-U tunnel.<br>NOTE: Measurement Object Class, NRCellIDU, is different to A.1.2.<br>It is optional counter for O-DU.<br>The counter is split into subcounters per S-NSSAI. The counter is recommended when related slice feature is supported.<br>The counter is split into subcounter of subcounter per PmCountGroup. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is accumulated by the volume of UL PDCP PDU whenever the UL PDCP PDU is transmitted from the Cell via F1 U UL GTP-u tunnel.<br>S-NSSAI subcounter is maintained, the number of measurements is accumulated per the number of supported S-NSSAI. If related slice feature is not supported, only the S-NSSAI #0 is used.<br>PmCountGroup subcounter of subcounter is maintained, the number of measurements is accumulated per the number of supported PmCountGroup. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.F1.UIPdcPduCellVOITxF1UU1. <i>SNSSAI</i> . <i>PmGroup</i> , where <i>SNSSAI</i> is S-NSSAI.<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | NRCellIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## A.1.15 DL PDCP PDU volume received via F1-U DL GTP-U tunnel + +### A.1.15.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.F1.DIPdcpPduCellVolRxF1UDI | +| Description | This counter provides the DL PDCP PDU volume of the cell received via F1-U DL GTP-U tunnel.<br>NOTE: Measurement Object Class, NRCellDU, is different to A.1.6.<br>It is optional counter for O-DU.<br>The counter is split into subcounters per S-NSSAI. The counter is recommended when related slice feature is supported.<br>The counter is split into subcounter of subcounter per PmCountGroup. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement counter is accumulated by the volume of DL PDCP PDU whenever the DL PDCP PDU is received to the Cell via F1 U DL GTP-u tunnel.<br>S-NSSAI subcounter is maintained, the number of measurements is accumulated per the number of supported S-NSSAI. If related slice feature is not supported, only the S-NSSAI #0 is used.<br>PmCountGroup subcounter of subcounter is maintained, the number of measurements is accumulated per the number of supported PmCountGroup. | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.F1.DIPdcpPduCellVolTxF1UDI. <i>SNSSAI.PmGroup</i> , where <i>SNSSAI</i> is the S-NSSAI.<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2 NR RLC performance counters + +### A.2.1 Received UL RLC PDUs + +#### A.2.1.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.RxUIRlcPdu | +| Description | This counter provides the number of the received UL RLC PDUs.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the UL RLC PDU is received when the QCI or the 5QI of the UL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.RxUIRlcPdu. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | + +| | | +|----------------------|--------------------------------------------------| +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.2 Received UL RLC PDU volume + +### A.2.2.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.RxUIRlcPduVol | +| Description | This counter provides the received UL RLC PDU volume.<br>It is recommended to support for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is incremented by the volume of the UL RLC PDU whenever the UL RLC PDU is received when the QCI or the 5QI of the UL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.RLC.RxUIRlcPduVol. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.3 Request for UL RLC PDUs retransmission + +### A.2.3.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.ReqUIRlcPduRetrans | +| Description | This counter provides the number of the requests for UL RLC PDUs retransmission.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the UL RLC PDU is received when the QCI or the 5QI of the UL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.ReqUIRlcPduRetrans. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.4 Transmitted DL RLC PDUs + +### A.2.4.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.TxDIRlcPdu | +| Description | This counter provides the number of the transmitted DL RLC PDUs. It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the DL RLC PDU is transmitted when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.TxDIRlcPdu. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.5 Transmitted DL RLC PDU volume + +### A.2.5.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.TxDIRlcPduVol | +| Description | This counter provides the transmitted DL RLC PDU volume. It is recommendedf to support for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is incremented by the volume of the DL RLC PDU whenever the DL RLC PDU is transmitted when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.RLC.TxDIRlcPduVol. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.6 Retransmitted DL RLC PDUs + +### A.2.6.1 Performance Counter Table + +| | | +|-------------------|------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.RxDIRlcPdu | +| Description | This counter provides the number of the DL RLC PDUs retransmitted in RLC layer. It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | Measurement subcounter is incremented by 1 whenever the DL RLC PDU is retransmitted in RLC layer when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.RxDIRlcPdu. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## A.2.7 Retransmitted DL RLC PDU volume + +2 + +### A.2.7.1 Performance Counter Table + +3 + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.RxDIRlcPduVol | +| Description | This counter provides the DL RLC PDU volume retransmitted in RLC layer.<br>It is recommended to support for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is incremented by the volume of the DL RLC PDU whenever the DL RLC PDU is retransmitted in RLC layer when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.RLC.RxDIRlcPduVol. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## A.2.8 UL RLC PDUs discarded due to bearer release + +5 + +### A.2.8.1 Performance Counter Table + +6 + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.UIRlcPduDiscardBearerRel | +| Description | This counter provides the number of the UL RLC PDUs discarded due to bearer release.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the UL RLC PDU is discarded due to bearer release when the QCI or the 5QI of the UL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.UIRlcPduDiscardBearerRel. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number: | + +| | | +|--------------------------|--------------------------------------------------| +| | 0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.9 UL RLC PDU volume discarded due to bearer release + +### A.2.9.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.UIRlcPduVolDiscardBearerRel | +| Description | This counter provides the UL RLC PDU volume discarded due to bearer release.<br>It is recommended to support for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is incremented by the volume of the UL RLC PDU whenever the DL RLC PDU is discarded due to bearer release when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.RLC.UIRlcPduVolDiscardBearerRel. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.10 UL RLC PDUs discarded due to RLC re-establishment + +### A.2.10.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.UIRlcPduDiscardRlcReest | +| Description | This counter provides the number of the UL RLC PDUs discarded due to RLC re-establishment.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the UL RLC PDU is discarded due to RLC re-establishment when the QCI or the 5QI of the UL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.UIRlcPduDiscardRlcReest. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | + +| | | +|------------|--------------------------------------------------| +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.11 UL RLC PDU volume discarded due to RLC re-establishment + +### A.2.11.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.UIRlcPduVolDiscardRlcReest | +| Description | This counter provides the UL RLC PDU volume discarded due to RLC re-establishment.<br>It is recommended to support for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is incremented by the volume of the UL RLC PDU whenever the UL RLC PDU is discarded due to RLC re-establishment when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.RLC.UIRlcPduVolDiscardRlcReest. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.12 UL RLC PDUs discarded due to other causes + +### A.2.12.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.RlcPduDiscardOther | +| Description | This counter provides the number of the UL RLC PDUs discarded due to other causes.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the UL RLC PDU is discarded for reason other than bearer release and RLC re-establishment when the QCI or the 5QI of the UL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.RlcPduDiscardOther. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.13 UL RLC PDU volume discarded due to other causes + +### A.2.13.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.UIRlcPduVolDiscardOther | +| Description | This counter provides the UL RLC PDU volume discarded due to other causes.<br>It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of the UL RLC PDU whenever the UL RLC PDU is discarded for reason other than bearer release and RLC re-establishment when the QCI or the 5QI of the UL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.RLC.UIRlcPduVolDiscardOther. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.14 DL RLC PDUs discarded due to bearer release + +### A.2.14.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.DIRlcPduDiscardBearerRel | +| Description | This counter provides the number of DL RLC PDUs discarded due to bearer release. This counter includes DL RLC PDUs which has transmitted or not lower layer.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the DL RLC PDU is discarded due to bearer release when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.DIRlcPduDiscardBearerRel. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.15 DL RLC PDU volume discarded due to bearer release + +### A.2.15.1 Performance Counter Table + +| | | +|------------------|-----------------------------------| +| Measurement Name | OR.RLC.DIRlcduVolDiscardBearerRel | +|------------------|-----------------------------------| + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Description | This counter provides the DL RLC PDU volume discarded due to bearer release. This counter includes DL RLC PDUs which has transmitted or not lower layer.<br>It is recommended to support for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is incremented by the volume of the DL RLC PDU whenever the DL RLC PDU is discarded due to bearer release when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.RLC.DIRlcduVolDiscardBearerRel. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.16 DL RLC PDUs discarded due to RLC re-establishment + +### A.2.16.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.DIRlcPduDiscardRlcReest | +| Description | This counter provides the number of the DL RLC PDUs discarded due to RLC re-establishment. This counter includes DL RLC PDUs which has transmitted or not lower layer.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the DL RLC PDU is discarded due to RLC re-establishment when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.DIRlcPduDiscardRlcReest. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.17 DL RLC PDU volume discarded due to RLC re-establishment + +### A.2.17.1 Performance Counter Table + +| | | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.DIRlcPduVolDiscardRlcReest | +| Description | This counter provides the DL RLC PDU volume discarded due to RLC re-establishment. This counter includes DL RLC PDUs which has transmitted or not lower layer.<br>It is recommended to support for O-DU. | + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is incremented by the volume of the DL RLC PDU whenever the DL RLC PDU is discarded due to RLC re-establishment when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.RLC.DIRlcPduVolDiscardRlcReest. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.18 DL RLC PDUs discarded due to full buffer + +### A.2.18.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.DIRlcSduDiscardFullBuffer | +| Description | This counter provides the number of the DL RLC PDUs discarded due to full buffer. This counter includes DL RLC PDUs which has transmitted or not lower layer.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the DL RLC PDU is discarded due to full buffer when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.DIRlcSduDiscardFullBuffer. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.2.19 DL RLC PDU volume discarded due to full buffer + +### A.2.19.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.DIRlcSduVolDiscardFullBuffer | +| Description | This counter provides the DL RLC PDU volume discarded due to full buffer. This counter includes DL RLC PDUs which has transmitted or not lower layer.<br>It is recommended to support for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is incremented by the volume of the DL RLC PDU whenever the DL RLC PDU is discarded due to full buffer when | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------| +| | the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.RLC.DIRlcSduVolDiscardFullBuffer. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.2.20 The number of exceeding maximum RLC retransmissions + +3 + +### A.2.20.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RLC.NumExceedMaxRlcRetrans | +| Description | This counter provides the number of received NACK for the final retransmission in RLC layer.<br>It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RLC status report including NACK for the final retransmission is received when the QCI or the 5QI of the DL RLC PDU is group of subcounter. <i>Pmgroup</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RLC.NumExceedMaxRlcRetrans. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | gNBDUFunction | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +5 + +## A.2.21 Average delay DL in gNB-DU + +6 + +### A.2.21.1 Performance Counter Table + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | DRB.RlcSduDelayDL | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.3.3.3<br><br><u>O-RAN addition:</u><br>It is optional counter for O-DU. | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.3.3.3 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.3.3.3<br><br><u>O-RAN addition:</u><br>The subcounter per QoS level should be regarded as subcounter per <i>PmGroup</i> , and the subcounter should be accumulated per subcounter. <i>Pmgroup</i> . | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.3.3.3 | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.3.3.3<br><br><u>O-RAN addition:</u><br>Subcounter OR.DRB.RlcSduDelayDl. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | <u>O-RAN Measurement Object Class:</u><br>gNBDUFunction | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.3.3.3 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.3.3.3 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.3.3.3 | + +## 1 A.2.22 IP Latency DL in gNB-DU + +### 3 A.2.22.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | DRB.RlcSduLatencyDl | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.3.4.2<br><br><u>O-RAN addition:</u><br>It is optional counter for O-DU. | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.3.4.2 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.3.4.2<br><br><u>O-RAN addition:</u><br>The subcounter per QoS level should be regarded as subcounter per <i>PmGroup</i> , and the subcounter should be accumulated per subcounter. <i>Pmgroup</i> . | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.3.4.2 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.3.4.2<br><br><u>O-RAN addition:</u><br>Subcounter OR.DRB.RlcSduLatencyDl. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | <u>O-RAN Measurement Object Class:</u><br>gNBDUFunction | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.3.4.2 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.3.4.2 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.3.4.2 | + +## 4 A.2.23 Received paging records + +### 5 A.2.23.1 Performance Counter Table + +| | | +|--------------------|------------------------------------------------| +| Measurement Name | PAG.ReceivedNbr | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.3 | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.3 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.3 | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.3 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.3 | + +| | | +|--------------------------|------------------------------------------------| +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.3 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.3 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.3 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.3 | + +## A.2.24 Discarded paging records + +### A.2.24.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------| +| Measurement Name | PAG.DiscardedNbr | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.6 | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.6 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.6 | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.6 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.6 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.6 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.6 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.6 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.27.6 | + +## A.3 NR MAC performance counters + +### A.3.1 Received UL MAC PDU volume + +#### A.3.1.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.MAC.RxUIMacPduVol | +| Description | This counter provides the UL MAC PDU volume received as initial transmission or retransmission in MAC layer.<br>It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of the UL MAC PDU whenever the UL MAC PDU is received as initial transmission or retransmission when the SSB for PUSCH is the group of subcounter. <i>SSB</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.MAC.RxUIMacPduVol. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.3.2 Transmitted DL MAC PDU volume + +#### A.3.2.1 Performance Counter Table + +| | | +|------------------|----------------------| +| Measurement Name | OR.MAC.TxDlMacPduVol | +|------------------|----------------------| + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Description | This counter provides the DL MAC PDU volume transmitted as initial transmission or retransmission in MAC layer.<br>It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the volume of the DL MAC PDU whenever the DL MAC PDU is transmitted as initial transmission or retransmission when the SSB for PDSCH is the group of subcounter. <i>SSB</i> . | +| Measurement Result | kilobyte (U32) | +| Measurement Type | OR.MAC.TxDlMacPduVol. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.3.3 Average delay DL air-interface + +### 3 A.3.3.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | DRB.AirIfDelayDl | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.1.1.1<br><br><u>O-RAN addition:</u><br>It is optional counter for O-DU. | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.1.1 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.1.1.1<br><br><u>O-RAN addition:</u><br>The subcounter per QoS level should be regarded as subcounter per <i>PmGroup</i> , and the subcounter should be accumulated per subcounter. <i>Pmgroup</i> . | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.1.1 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.1.1.1<br><br><u>O-RAN addition:</u><br>Subcounter OR.DRB.AirIfDelayDl. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.1.1 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.1.1 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.1.1 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.1.1 | + +4 + +## A.4 NR UL HARQ performance counters + +### A.4.1 Distribution of PUSCH per MCS (initial transmission) + +#### A.4.1.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULHARQ.DistPuschMcsInitial | +| Description | This counter provides the distributions of PUSCH at the initial transmission per MCS.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH is received for initial transmission when the MCS table of the PUSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PUSCH is group of subcounter. <i>MCSInitial</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ULHARQ.DistPuschMcsInitial. <i>MCSInitial</i> . <i>MCSTable</i> where <i>MCSInitial</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>28: $I_{MCS} = 28$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding<br>3: MCS index table for PUSCH with transform precoding and 64QAM (q=1)<br>4: MCS index table for PUSCH with transform precoding and 64QAM (q=2)<br>5: MCS index table 2 for PUSCH with transform precoding and 64QAM(q=1)<br>6: MCS index table 2 for PUSCH with transform precoding and 64QAM (q=2) | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.4.2 Distribution of PUSCH per MCS (initial transmission/CRC OK) + +#### A.4.2.1 Performance Counter Table + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULHARQ.DistPuschMcsInitialTxCRC | +| Description | This counter provides the distributions of the number of CRC succeeded for PUSCH at initial transmission per MCS.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH of which CRC is OK is received for initial transmission when the MCS table of the PUSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PUSCH is group of subcounter. <i>MCSInitial</i> . | +| Measurement Result | Integer number (U32) | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Type | <p>OR.ULHARQ.DistPuschMcsInitialTxCRC.<i>MCSInitial.MCSTable</i> where <i>MCSInitial</i> is the MCS index for initial transmission:</p> <p>0: <math>I_{MCS} = 0</math><br/> 1: <math>I_{MCS} = 1</math><br/> ...<br/> 28: <math>I_{MCS} = 28</math></p> <p><i>MCSTable</i> is the MCS table:</p> <p>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br/> 1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br/> 2: MCS index table 3 for PDSCH/PUSCH without transform precoding<br/> 3: MCS index table for PUSCH with transform precoding and 64QAM (<math>q=1</math>)<br/> 4: MCS index table for PUSCH with transform precoding and 64QAM (<math>q=2</math>)<br/> 5: MCS index table 2 for PUSCH with transform precoding and 64QAM(<math>q=1</math>)<br/> 6: MCS index table 2 for PUSCH with transform precoding and 64QAM (<math>q=2</math>)</p> | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.4.3 Distribution of PUSCH per MCS (any/CRC OK) + +3 + +### A.4.3.1 Performance Counter Table + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULHARQ.DistPuschMcsAny | +| Description | <p>This counter provides the distributions of PUSCH at initial transmission or retransmission per MCS.</p> <p>It is optional counter for O-DU.</p> | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH of which CRC is OK is received for initial transmission or retransmission when the MCS table of the PUSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PUSCH is group of subcounter. <i>MCSRetx</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | <p>OR.ULHARQ.DistPuschMcsAny.<i>MCSRetx.MCSTable</i> where <i>MCSRetx</i> is the MCS index for initial transmission:</p> <p>0: <math>I_{MCS} = 0</math><br/> 1: <math>I_{MCS} = 1</math><br/> ...<br/> 31: <math>I_{MCS} = 31</math></p> <p><i>MCSTable</i> is the MCS table:</p> <p>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br/> 1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br/> 2: MCS index table 3 for PDSCH/PUSCH without transform precoding<br/> 3: MCS index table for PUSCH with transform precoding and 64QAM (<math>q=1</math>)<br/> 4: MCS index table for PUSCH with transform precoding and 64QAM (<math>q=2</math>)</p> | + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------| +| | 5: MCS index table 2 for PUSCH with transform precoding and 64QAM(q=1)<br>6: MCS index table 2 for PUSCH with transform precoding and 64QAM (q=2) | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.4.4 Distribution of PUSCH per MCS (exceeding HARQ retransmission) + +### A.4.4.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULHARQ.DistPuschMcsExceedHarqRetrans | +| Description | This counter provides the distributions of the number of CRC failure for PUSCH at final retransmission per MCS.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH of which CRC is NG is received for final retransmission when the MCS table of the PUSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PUSCH is group of subcounter. <i>MCSRetx</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ULHARQ.DistPuschMcsExceedHarqRetrans. <i>MCSRetx</i> . <i>MCSTable</i><br>where <i>MCSRetx</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>31: $I_{MCS} = 31$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding<br>3: MCS index table for PUSCH with transform precoding and 64QAM (q=1)<br>4: MCS index table for PUSCH with transform precoding and 64QAM (q=2)<br>5: MCS index table 2 for PUSCH with transform precoding and 64QAM(q=1)<br>6: MCS index table 2 for PUSCH with transform precoding and 64QAM (q=2) | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.4.5 Distribution of PUSCH per MCS (MU-MIMO/initial transmission) + +### A.4.5.1 Performance Counter Table + +| | | +|------------------|----------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULHARQ.DistPuschMcsMuMimoInitialTx | +| Description | This counter provides the distributions of PUSCH at initial transmission in MU-MIMO usage per MCS. | + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH is transmitted (including MU-MIMO usage) for initial transmission when the MCS table of the PUSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PUSCH is group of subcounter. <i>MCSInitial</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ULHARQ.DistPuschMcsMuMimoInitialTx. <i>MCSInitial</i> . <i>MCSTable</i><br>where <i>MCSInitial</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>27: $I_{MCS} = 27$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding<br>3: MCS index table for PUSCH with transform precoding and 64QAM (q=1)<br>4: MCS index table for PUSCH with transform precoding and 64QAM (q=2)<br>5: MCS index table 2 for PUSCH with transform precoding and 64QAM(q=1)<br>6: MCS index table 2 for PUSCH with transform precoding and 64QAM (q=2) | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.4.6 Distribution of PUSCH per MCS (MU-MIMO/initial transmission/ACK) + +### A.4.6.1 Performance Counter Table + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULHARQ.DistPuschMcsMuMimoInitialTxAck | +| Description | This counter provides the distributions of the number of HARQ-ACK for PUSCH at initial transmission in MU-MIMO usage per MCS.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH is which of CRC is OK is transmitted (including MU-MIMO usage) for initial transmission when the MCS table of the PUSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PUSCH is group of subcounter. <i>MCSInitial</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ULHARQ.DistPuschMcsMuMimoInitialTxAck. <i>MCSInitial</i> . <i>MCSTable</i><br>where <i>MCSInitial</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>27: $I_{MCS} = 27$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | 3: MCS index table for PUSCH with transform precoding and 64QAM (q=1)<br>4: MCS index table for PUSCH with transform precoding and 64QAM (q=2)<br>5: MCS index table 2 for PUSCH with transform precoding and 64QAM(q=1)<br>6: MCS index table 2 for PUSCH with transform precoding and 64QAM (q=2) | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## A.5 NR DL HARQ performance counters + +### A.5.1 Distribution of PDSCH per MCS (initial transmission) + +#### A.5.1.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLHARQ.DistPdschMcsInitial | +| Description | This counter provides the distributions of PDSCH at initial transmission. This counter excludes MU-MIMO usage. It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted (except for MU-MIMO usage) for initial transmission when the MCS table of the PDSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PDSCH is group of subcounter. <i>MCSInitial</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLHARQ.DistPdschMcsInitial. <i>MCSInitial</i> . <i>MCSTable</i> where <i>MCSInitial</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>28: $I_{MCS} = 28$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +5 + +### A.5.2 Distribution of PDSCH per MCS (initial transmission/ACK) + +#### A.5.2.1 Performance Counter Table + +| | | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLHARQ.DistPdschMcsInitialTxAck | +| Description | This counter provides the distributions of the number of HARQ-ACK for PDSCH at initial transmission per MCS. This counter excludes MU-MIMO usage. | + +7 + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH (except for MU-MIMO usage) of which CRC is OK is transmitted for initial transmission when the MCS table of the PDSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PDSCH is group of subcounter. <i>MCSInitial</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLHARQ.DistPdschMcsInitialTxAck. <i>MCSInitial</i> . <i>MCSTable</i> where <i>MCSInitial</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>28: $I_{MCS} = 28$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.5.3 Distribution of PDSCH per MCS (any/ACK) + +### A.5.3.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLHARQ.DistPdschMcsAny | +| Description | This counter provides the distributions of the number of HARQ-ACK for PDSCH at initial transmission or retransmission per MCS. This counter excludes MU-MIMO usage.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH of which CRC is OK is received (except for MU-MIMO usage) for initial transmission or retransmission when the MCS table of the PDSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PDSCH is group of subcounter. <i>MCSRetx</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLHARQ.DistPdschMcsAny. <i>MCSRetx</i> . <i>MCSTable</i> where <i>MCSRetx</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>31: $I_{MCS} = 31$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | + +| | | +|---------|--------------------------------------------------| +| Purpose | Network Operator's Traffic Engineering Community | +|---------|--------------------------------------------------| + +## A.5.4 Distribution of PDSCH per MCS (exceeding HARQ retransmission) + +### A.5.4.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLHARQ.DistPdschMcsExceedHarqRetrans | +| Description | This counter provides the distributions of the number of HARQ-NACK for PUSCH at final retransmission per MCS. This counter excludes MU-MIMO usage.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH of which CRC is NG is transmitted (except for MU-MIMO usage) for final transmission when the MCS table of the PDSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PDSCH is group of subcounter. <i>MCSRetx</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLHARQ.DistPdschMcsExceedHarqRetrans. <i>MCSRetx</i> . <i>MCSTable</i><br>where <i>MCSRetx</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br><br>31: $I_{MCS} = 31$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.5.5 Distribution of PDSCH per MCS (MU-MIMO/initial transmission) + +### A.5.5.1 Performance Counter Table + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLHARQ.DistPdschMcsMuMimoInitialTx | +| Description | This counter provides the distributions of PDSCH at initial transmission in MU-MIMO usage per MCS.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted (including MU-MIMO usage) for initial transmission when the MCS table of the PDSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PDSCH is group of subcounter. <i>MCSInitial</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLHARQ.DistPdschMcsMuMimoInitialTx. <i>MCSInitial</i> . <i>MCSTable</i><br>where <i>MCSInitial</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br><br>28: $I_{MCS} = 28$ | + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p><i>MCSTable</i> is the MCS table:</p> <p>0: MCS index table 1 for PDSCH/PUSCH without transform precoding</p> <p>1: MCS index table 2 for PDSCH/PUSCH without transform precoding</p> <p>2: MCS index table 3 for PDSCH/PUSCH without transform precoding</p> | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.5.6 Distribution of PDSCH per MCS (MU-MIMO/initial transmission/ACK) + +### A.5.6.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLHARQ.DistPdschMcsMuMimoInitialTxAck | +| Description | <p>This counter provides the distributions of the number of HARQ-ACK for PDSCH at initial transmission in MU-MIMO usage per MCS.</p> <p>It is optional counter for O-DU.</p> | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is which of CRC is OK is transmitted (including MU-MIMO usage) for initial transmission when the MCS table of the PDSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PDSCH is group of subcounter. <i>MCSInitial</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | <p>OR.DLHARQ.DistPdschMcsMuMimoInitialTxAck.<i>MCSInitial</i>.<i>MCSTable</i> where <i>MCSInitial</i> is the MCS index for initial transmission:</p> <p>0: <math>I_{MCS} = 0</math></p> <p>1: <math>I_{MCS} = 1</math></p> <p>...</p> <p>28: <math>I_{MCS} = 28</math></p> <p><i>MCSTable</i> is the MCS table:</p> <p>0: MCS index table 1 for PDSCH/PUSCH without transform precoding</p> <p>1: MCS index table 2 for PDSCH/PUSCH without transform precoding</p> <p>2: MCS index table 3 for PDSCH/PUSCH without transform precoding</p> | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.6 NR UL Signal Quality Level performance counters + +### A.6.1 Distribution of PUSCH per MCS (Rank1) + +#### A.6.1.1 Performance Counter Table + +| | | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.DistPuschMcsRank1 | +| Description | <p>This counter provides the distributions of PUSCH transmitted with rank 1 per MCS.</p> <p>It is optional counter for O-DU.</p> | +| Collection Method | CC (Cumulative Counter) | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH is received with Rank 1 when the MCS table of the PUSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PUSCH is group of subcounter. <i>MCSRetx</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ULSQL.DistPuschMcsRank1. <i>MCSRetx</i> . <i>MCSTable</i> where <i>MCSRetx</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br><br>31: $I_{MCS} = 31$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding<br>3: MCS index table for PUSCH with transform precoding and 64QAM (q=1)<br>4: MCS index table for PUSCH with transform precoding and 64QAM (q=2)<br>5: MCS index table 2 for PUSCH with transform precoding and 64QAM(q=1)<br>6: MCS index table 2 for PUSCH with transform precoding and 64QAM (q=2) | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.6.2 Distribution of PUSCH per MCS (Rank2) + +### A.6.2.1 Performance Counter Table + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.DistPuschMcsRank2 | +| Description | This counter provides the distributions of PUSCH transmitted with rank 2 per MCS.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH is received with Rank 2 when the MCS table of the PUSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PUSCH is group of subcounter. <i>MCSRetx</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ULSQL.DistPuschMcsRank2. <i>MCSRetx</i> . <i>MCSTable</i> where <i>MCSRetx</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br><br>31: $I_{MCS} = 31$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | 3: MCS index table for PUSCH with transform precoding and 64QAM (q=1)<br>4: MCS index table for PUSCH with transform precoding and 64QAM (q=2)<br>5: MCS index table 2 for PUSCH with transform precoding and 64QAM(q=1)<br>6: MCS index table 2 for PUSCH with transform precoding and 64QAM (q=2) | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.6.3 Distribution of PUSCH per SSB (Rank1) + +3 + +### A.6.3.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.DistPuschSsbBeamRank1 | +| Description | This counter provides the distributions of PUSCH transmitted with rank 1 per SSB.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH is received with Rank 1 when the SSB used for the PUSCH is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ULSQL.DistPuschSsbBeamRank1.. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | <b>NRCelIDU</b> | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +5 + +## A.6.4 Distribution of PUSCH per SSB (Rank2) + +6 + +### A.6.4.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.DistPuschSsbBeamRank2 | +| Description | This counter provides the distributions of PUSCH transmitted with rank 2 per SSB.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH is received with Rank 2 when the SSB used for the PUSCH is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ULSQL.DistPuschSsbBeamRank2.. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | + +| | | +|----------------------|--------------------------------------------------| +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.6.5 PUSCH received power + +### A.6.5.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.PuschRxPower | +| Description | This counter measures the following $x$ and provides $\text{round}(x, 2) \cdot 10^2$ . $x$ is the statistics of received power of FL DMRS of PUSCH. This counter obtains the power for every slot or mini slot in which PUSCH reception is expected. The power is normalized by PRB and antenna port. If Rx beam is created by some antenna ports, this counter is calculated with the power of only the antenna ports used to create Rx beam.<br>It is recommended to support for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter of subcounter. <i>statistic</i> (avg.) is calculated by $\text{round}(x/y, 2) * 10^2$ , where:<br><br>$x$ is incremented by the volume of power of front loaded DMRS of PUSCH whenever PUSCH reception is expected when SSB used for PUSCH is group of subcounter.SSB. The power is normalized by PRB and antenna port. If Rx beam is created by some antenna ports, this counter is calculated with the power of only the antenna ports used to create Rx beam.<br><br>$y$ is incremented by 1 whenever PUSCH reception is expected when SSB used for PUSCH is group of subcounter.SSB.<br><br>Measurement subcounter of subcounter. <i>statistic</i> (max/min) is maximum/minimum number of $\text{round}(z, 2) * 10^2$ . It is assigned whenever $z$ is updated by the volume $\text{round}(z, 2) * 10^2$ , if $\text{round}(z, 2) * 10^2$ is bigger/smaller than previously counted volume, where:<br><br>$z$ is the volume of power of front loaded DMRS of PUSCH whenever PUSCH reception is expected when SSB used for PUSCH is group of subcounter.SSB. The power is normalized by PRB and antenna port. If Rx beam is created by some antenna ports, this counter is calculated with the power of only the antenna ports used to create Rx beam. | +| Measurement Result | dBm/ $10^2$ (S16) | +| Measurement Type | OR.ULSQL.PuschRxPower.SSB. <i>statistic</i> where SSB is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63<br><br><i>statistic</i> is<br>0: average<br>1: maximum<br>2: minimum | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.6.6 PUSCH RSSI + +### A.6.6.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.PuschRssi | +| Description | This counter measures the following x and provides $\text{round}(x, 2) \cdot 10^2$ . x is the statistic of the power of the REs in which PUSCH DMRS reception is expected.<br>It is recommended to support for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter of subcounter. <i>statistic</i> (avg.) is calculated by $\text{round}(x/y, 2) \cdot 10^2$ , where:<br><br>x is incremented by the volume of power of the RE which PUSCH DMRS reception is expected whenever PUSCH reception is expected when SSB used for PUSCH is group of subcounter. <i>SSB</i> .<br><br>y is incremented by 1 whenever PUSCH reception is expected when SSB used for PUSCH is group of subcounter. <i>SSB</i> .<br><br>Measurement subcounter of subcounter. <i>statistic</i> (max/min) is maximum/minimum number of $\text{round}(z, 2) \cdot 10^2$ . It is assigned whenever z is updated by the volume $\text{round}(z, 2) \cdot 10^2$ , if $\text{round}(z, 2) \cdot 10^2$ is bigger/smaller than previously counted volume, where:<br><br>z is the volume of power of the RE which PUSCH DMRS reception is expected whenever PUSCH reception is expected when SSB used for PUSCH is group of subcounter. <i>SSB</i> . | +| Measurement Result | dBm/10 <sup>2</sup> (S16) | +| Measurement Type | OR.ULSQL.PuschRssi. <i>SSB.statistic</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63<br><br><i>statistic</i> is<br>0: average<br>1: maximum<br>2: minimum | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.6.7 PUSCH SINR + +### A.6.7.1 Performance Counter Table + +| | | +|-------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.PuschSinr | +| Description | This counter measures the following x and provides $\text{round}(x, 2) \cdot 10^2$ . x is the statistics of PUSCH with 2 dB bin of SINR of UE specific PUSCH.<br>It is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter of subcounter. <i>statistic</i> (avg.) is calculated by $\text{round}(x/y, 2) \cdot 10^2$ , where: | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>x is incremented by the volume of SINR of the UE specific PUSCH when SSB used for PUSCH is group of subcounter.<i>SSB</i> and when MIMO layer of the PUSCH is group of subcounter.<i>MIMO</i>.</p> <p>y is incremented by 1 whenever PUSCH which power detection check is OK is received when SSB used for PUSCH is group of subcounter.<i>SSB</i> and when MIMO layer of the PUSCH is group of subcounter.<i>MIMO</i>.</p> <p>Measurement subcounter of subcounter.<i>statistic</i>(max/min) is maximum/minimum number of round(z, 2) * 10<sup>2</sup>. It is assigned whenever z is updated by the volume round(z, 2) * 10<sup>2</sup>, if round(z, 2) * 10<sup>2</sup> is bigger/smaller than previously counted volume, where:</p> <p>z is the volume of SINR of the UE specific PUSCH when SSB used for PUSCH is group of subcounter.<i>SSB</i> and when MIMO layer of the PUSCH is group of subcounter.<i>MIMO</i>.</p> | +| Measurement Result | dB/10 <sup>2</sup> (S16) | +| Measurement Type | <p>OR.ULSQL.PuschSinr.<i>SSB.MIMO.statistic</i> where <i>SSB</i> is the SSB index:</p> <p>0: #0<br/> 1: #1<br/> ...<br/> 63: #63</p> <p><i>MIMO</i> is the number of MIMO layer:</p> <p>0: 1 layer<br/> 1: 2 layer<br/> ...<br/> 7: 8 layer</p> <p><i>statistic</i> is</p> <p>0: average<br/> 1: maximum<br/> 2: minimum</p> | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.6.8 PUCCH RSSI + +### A.6.8.1 Performance Counter Table + +| | | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.PucchRssi | +| Description | <p>This counter measures the following x and provides round(x, 2) · 10<sup>2</sup>. x is the statistics of the power of the REs in which PUCCH DMRS reception is expected.</p> <p>It is recommended to support for O-DU.</p> | +| Collection Method | SI (Status Inspection) | +| Condition | <p>Measurement subcounter of subcounter.<i>statistic</i>(avg.) is calculated by round(x/y, 2) * 10<sup>2</sup>, where:</p> <p>x is incremented by the volume of power of the RE which PUCCH DMRS reception is expected whenever PUCCH reception is expected when SSB used for PUCCH is group of subcounter.<i>SSB</i>.</p> | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>y is incremented by 1 whenever PUCCH reception is expected when SSB used for PUCCH is group of subcounter.<i>SSB</i>.</p> <p>Measurement subcounter of subcounter.<i>statistic</i>(max/min) is maximum/minimum number of <math>\text{round}(z, 2) * 10^2</math>. It is assigned whenever z is updated by the volume <math>\text{round}(z, 2) * 10^2</math>, if <math>\text{round}(z, 2) * 10^2</math> is bigger/smaller than previously counted volume, where:</p> <p>z is the volume of power of the RE which PUCCH DMRS reception is expected whenever PUCCH reception is expected when SSB used for PUCCH is group of subcounter.<i>SSB</i>.</p> | +| Measurement Result | dBm/10 <sup>2</sup> (S16) | +| Measurement Type | OR.ULSQL.PucchRssi. <i>SSB.statistic</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63<br><i>statistic</i> is<br>0: average<br>1: maximum<br>2: minimum | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +2 + +## A.6.9 PUCCH SINR + +3 + +### A.6.9.1 Performance Counter Table + +| | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.PucchSinr | +| Description | <p>This counter measures the following x and provides <math>\text{round}(x, 2) * 10^2</math>. x is the statistics of SINR of UE specific PUCCH.</p> <p>It is optional counter for O-DU.</p> | +| Collection Method | SI (Status Inspection) | +| Condition | <p>Measurement subcounter of subcounter.<i>statistic</i>(avg.) is calculated by <math>\text{round}(x/y, 2) * 10^2</math>, where:</p> <p>x is incremented by the volume of SINR of the UE specific PUCCH when SSB used for PUCCH is group of subcounter.<i>SSB</i>.</p> <p>y is incremented by 1 whenever PUCCH which power detection check is OK is received when SSB used for PUCCH is group of subcounter.<i>SSB</i>.</p> <p>Measurement subcounter of subcounter.<i>statistic</i>(max/min) is maximum/minimum number of <math>\text{round}(z, 2) * 10^2</math>. It is assigned whenever z is updated by the volume <math>\text{round}(z, 2) * 10^2</math>, if <math>\text{round}(z, 2) * 10^2</math> is bigger/smaller than previously counted volume, where:</p> <p>z is the volume of SINR of the UE specific PUCCH when SSB used for PUCCH is group of subcounter.<i>SSB</i>.</p> | +| Measurement Result | dB/10 <sup>2</sup> (S16) | +| Measurement Type | OR.ULSQL.PucchSinr. <i>SSB.statistic</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | + +| | | +|--------------------------|---------------------------------------------------------------| +| | <i>statistic</i> is<br>0: average<br>1: maximum<br>2: minimum | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.6.10 PRACH preamble correlation value + +### A.6.10.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.PrachPreambleCorrelationValue | +| Description | <p>This counter measures the following <math>x</math> and provides <math>\text{round}(x, 2) \cdot 10^2</math>. <math>x</math> is the statistics of the correlation value among preambles of the PRB where PRACH preamble is detected. This counter normalized by PRB. It is recommended to support for O-DU.</p> | +| Collection Method | SI (Status Inspection) | +| Condition | <p>Measurement subcounter of subcounter.<i>statistic</i>(avg.) is calculated by <math>\text{round}(x/y, 2) \cdot 10^2</math>, where:</p> <p><math>x</math> is incremented by the correlation volume among preambles of the PRB whenever PRACH preamble is detected when SSB used for PRACH is group of subcounter.<i>SSB</i>.</p> <p><math>y</math> is incremented by 1 whenever PRACH preamble is detected when SSB used for PRACH is group of subcounter.<i>SSB</i>.</p> <p>Measurement subcounter of subcounter.<i>statistic</i>(max/min) is maximum/minimum number of <math>\text{round}(z, 2) \cdot 10^2</math>. It is assigned whenever <math>z</math> is updated by the volume <math>\text{round}(z, 2) \cdot 10^2</math>, if <math>\text{round}(z, 2) \cdot 10^2</math> is bigger/smaller than previously counted volume, where:</p> <p><math>z</math> is the correlation volume among preambles of the PRB whenever PRACH preamble is detected when SSB used for PRACH is group of subcounter.<i>SSB</i>.</p> | +| Measurement Result | dBm/ $10^2$ (S16) | +| Measurement Type | <p>OR.ULSQL.PrachPreambleCorrelationValue.<i>SSB.statistic</i> where <i>SSB</i> is the SSB index:</p> <p>0: #0<br/> 1: #1<br/> ...<br/> 63: #63</p> <p><i>statistic</i> is<br/> 0: average<br/> 1: maximum<br/> 2: minimum</p> | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.6.11 RSSI of PRACH transmission occasion + +### A.6.11.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.RssiPrachTxOccasion | +| Description | This counter measures the following x and provides $\text{round}(x, 2) \cdot 10^2$ . x is the statistics of the RACH occasion RSSI. This counter is normalized by PRB.<br>It is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter of subcounter. <i>statistic</i> (avg.) is calculated by $\text{round}(x/y, 2) * 10^2$ , where:<br><br>x is incremented by the volume of RSSI at every PRACH occasion when SSB used for PRACH is group of subcounter. <i>SSB</i> .<br><br>y is incremented by 1 at every PRACH occasion when SSB used for PRACH is group of subcounter. <i>SSB</i> .<br><br>Measurement subcounter of subcounter. <i>statistic</i> (max/min) is maximum/minimum number of $\text{round}(z, 2) * 10^2$ . It is assigned whenever z is updated by the volume $\text{round}(z, 2) * 10^2$ , if $\text{round}(z, 2) * 10^2$ is bigger/smaller than previously counted volume, where:<br><br>z is the volume of RSSI at every PRACH occasion when SSB used for PRACH is group of subcounter. <i>SSB</i> . | +| Measurement Result | dBm/ $10^2$ (S16) | +| Measurement Type | OR.ULSQL.RssiPrachTxOccasion. <i>SSB.statistic</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63<br><i>statistic</i> is<br>0: average<br>1: maximum<br>2: minimum | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.6.12 Distribution of path loss for FR1 + +### A.6.12.1 Performance Counter Table + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.DistPathlossFr1 | +| Description | This counter provides the distributions of PUSCH including PHR with a certain bin of the pathloss. This counter is for FR1.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | This subcounter is measured only when the cell uses FR1.<br>Measurement subcounter is incremented by 1 whenever PHR is received when the SSB used for the PUSCH is group of subcounter. <i>SSB</i> and when the pathloss calculated with the PHR is group of subcounter. <i>binX</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ULSQL.DistPathlossFr1. <i>SSB.binX</i> where <i>SSB</i> is the SSB index: | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | 0: #0<br>1: #1<br>...<br>63: #63<br>binX is the bin of the pathloss, x.<br>Bin1: $0 \text{ dB} \leq x < 40 \text{ dB}$<br>Bin2: $40 \text{ dB} \leq x < 45 \text{ dB}$<br>Bin3: $45 \text{ dB} \leq x < 50 \text{ dB}$<br>...<br>Bin25: $155 \text{ dB} \leq x$ | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.6.13 Path loss for FR2 + +### 3 A.6.13.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.PathlossFr2 | +| Description | This counter measures the following x and provides $\text{round}(x, 2) \cdot 10^2$ . x is the statistics of the pathloss. This counter is for FR2.<br>It is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | This subcounter is measured only when the cell uses FR2.<br><br>Measurement subcounter of subcounter. <i>statistic</i> (avg.) is calculated by $\text{round}(x/y, 2) \cdot 10^2$ , where:<br><br>x is incremented by the volume of the pathloss calculated with PHR whenever PHR is received when the SSB used for the PUSCH is group of subcounter. <i>SSB</i> .<br><br>y is incremented by 1 whenever PHR is received when the SSB used for the PUSCH is group of subcounter. <i>SSB</i><br><br>Measurement subcounter of subcounter. <i>statistic</i> (max/min) is maximum/minimum number of $\text{round}(z, 2) \cdot 10^2$ . It is assigned whenever z is updated by the volume $\text{round}(z, 2) \cdot 10^2$ , if $\text{round}(z, 2) \cdot 10^2$ is bigger/smaller than previously counted volume, where:<br><br>z is the volume of the pathloss calculated with PHR whenever PHR is received when the SSB used for the PUSCH is group of subcounter. <i>SSB</i> . | +| Measurement Result | dB/10 <sup>2</sup> (S16) | +| Measurement Type | OR.ULSQL.PathlossFr2. <i>SSB.statistic</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63<br><i>statistic</i> is<br>0: average<br>1: maximum<br>2: minimum | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | + +| | | +|---------|--------------------------------------------------| +| Purpose | Network Operator's Traffic Engineering Community | +|---------|--------------------------------------------------| + +## A.6.14 Detection of UL out-of-sync. + +### A.6.14.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ULSQL.DetectUlOutSync | +| Description | This counter provides the number of the detection of UL out-of-sync for bearer type change from SN terminated split bearer to SN terminated MCG bearer or SgNB release or RRC release.<br>It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever the UL out-of-sync is detected per SSB index of the UE: #0, #1, ..., #63 as subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.ULSQL.DetectUlOutSync. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7 NR DL Signal Quality Level performance counters + +### A.7.1 Distribution of PDSCH per MCS (Rank1) + +#### A.7.1.1 Performance Counter Table + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.DistPdschMcsRank1 | +| Description | This counter provides the distributions of PDSCH transmitted with rank 1 per MCS.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted with Rank 1 when the MCS table of the PDSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PDSCH is group of subcounter. <i>MCSRetx</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLSQL.DistPdschMcsRank1. <i>MCSRetx</i> . <i>MCSTable</i> where <i>MCSRetx</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>31: $I_{MCS} = 31$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | 3: MCS index table for PUSCH with transform precoding and 64QAM (q=1)<br>4: MCS index table for PUSCH with transform precoding and 64QAM (q=2)<br>5: MCS index table 2 for PUSCH with transform precoding and 64QAM(q=1)<br>6: MCS index table 2 for PUSCH with transform precoding and 64QAM (q=2) | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7.2 Distribution of PDSCH per MCS (Rank2) + +### A.7.2.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.DistPdschMcsRank2 | +| Description | This counter provides the distributions of PDSCH transmitted with rank 2 per MCS.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted with Rank 2 when the MCS table of the PDSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PDSCH is group of subcounter. <i>MCSRetx</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLSQL.DistPdschMcsRank2. <i>MCSRetx</i> . <i>MCSTable</i> where <i>MCSRetx</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>31: $I_{MCS} = 31$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding<br>3: MCS index table for PUSCH with transform precoding and 64QAM (q=1)<br>4: MCS index table for PUSCH with transform precoding and 64QAM (q=2)<br>5: MCS index table 2 for PUSCH with transform precoding and 64QAM(q=1)<br>6: MCS index table 2 for PUSCH with transform precoding and 64QAM (q=2) | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7.3 Distribution of PDSCH per MCS (Rank3) + +### A.7.3.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.DistPdschMcsRank3 | +| Description | This counter provides the distributions of PDSCH transmitted with rank 3 per MCS.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted with Rank 3 when the MCS table of the PDSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PDSCH is group of subcounter. <i>MCSRetx</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLSQL.DistPdschMcsRank3. <i>MCSRetx</i> . <i>MCSTable</i> where <i>MCSRetx</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>31: $I_{MCS} = 31$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding<br>3: MCS index table for PUSCH with transform precoding | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7.4 Distribution of PDSCH per MCS (Rank4) + +### A.7.4.1 Performance Counter Table + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.DistPdschMcsRank4 | +| Description | This counter provides the distributions of PDSCH transmitted with rank 4 per MCS.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted with Rank 4 when the MCS table of the PDSCH is group of subcounter. <i>MCSTable</i> and when the MCS index of the PDSCH is group of subcounter. <i>MCSRetx</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLSQL.DistPdschMcsRank4. <i>MCSRetx</i> . <i>MCSTable</i> where <i>MCSRetx</i> is the MCS index for initial transmission:<br>0: $I_{MCS} = 0$<br>1: $I_{MCS} = 1$<br>...<br>31: $I_{MCS} = 31$<br><i>MCSTable</i> is the MCS table:<br>0: MCS index table 1 for PDSCH/PUSCH without transform precoding<br>1: MCS index table 2 for PDSCH/PUSCH without transform precoding | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------| +| | precoding<br>2: MCS index table 3 for PDSCH/PUSCH without transform precoding<br>3: MCS index table for PUSCH with transform precoding | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7.5 Distribution of PDSCH per SSB (Rank1) + +### A.7.5.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.DistPdschSsbBeamRank1 | +| Description | This counter provides the distributions of PDSCH transmitted with rank 1 per SSB.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted with Rank 1 when the SSB used for the PDSCH is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLSQL.DistPdschSsbBeamRank1.. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7.6 Distribution of PDSCH per SSB (Rank2) + +### A.7.6.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.DistPdschSsbBeamRank2 | +| Description | This counter provides the distributions of PDSCH transmitted with rank 2 per SSB.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted with Rank 2 when the SSB used for the PDSCH is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLSQL.DistPdschSsbBeamRank2.. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7.7 Distribution of PDSCH per SSB (Rank3) + +### A.7.7.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.DistPdschSsbBeamRank3 | +| Description | This counter provides the distributions of PDSCH transmitted with rank 3 per SSB.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted with Rank 3 when the SSB used for the PDSCH is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLSQL.DistPdschSsbBeamRank3. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7.8 Distribution of PDSCH per SSB (Rank4) + +### A.7.8.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.DistPdschSsbBeamRank4 | +| Description | This counter provides the distributions of PDSCH transmitted with rank 4 per SSB.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted with Rank 4 when the SSB used for the PDSCH is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLSQL.DistPdschSsbBeamRank4. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7.9 Distribution of Wideband CQI for FR1 + +### A.7.9.1 Performance Counter Table + +| | | +|-------------------|----------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.DistWidebandCqiFR1 | +| Description | This counter provides the distributions of the wideband CQI reports.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | This subcounter is measured only when the cell uses FR1.<br>Measurement subcounter is incremented by 1 whenever CQI report is received when the SSB index used for the CQI report is group of subcounter. <i>SSB</i> , when the CQI table of the CQI report is group of subcounter. <i>CQITable</i> and when the CQI is group of subcounter. <i>CQI</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DLSQL.DistWidebandCqiFR1. <i>SSB.CQITable.CQI</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63<br><i>CQITable</i> is the CQI table:<br>0: table 1<br>1: table 2<br><i>CQI</i> is the CQI index:<br>0: CQI index 0<br>1: CQI index 1<br>...<br>15: CQI index 15 | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.7.10 Wideband CQI for FR2 + +### A.7.10.1 Performance Counter Table + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.WidebandCqiFR2 | +| Description | This counter measures the following $x$ and provides $\text{round}(x, 2) \cdot 10^2$ . $x$ is the statistics of linear value of the wideband CQI reports.<br>It is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | This subcounter is measured only when the cell uses FR2.<br><br>Measurement subcounter of subcounter. <i>statistic</i> (avg.) is calculated by $\text{round}(x/y, 2) * 10^2$ , where:<br><br><ul style="list-style-type: none"> <li><math>x</math> is incremented by the volume of CQI whenever CQI report is received when the SSB index used for the CQI report is group of subcounter.<i>SSB</i> and when the CQI table of the CQI report is group of subcounter.<i>CQITable</i>.</li> <li><math>y</math> is incremented by 1 whenever CQI report is received when the SSB index used for the CQI report is group of subcounter.<i>SSB</i> and when the CQI table of the CQI report is group of subcounter.<i>CQITable</i>.</li> </ul><br>Measurement subcounter of subcounter. <i>statistic</i> (max/min) is maximum/minimum number of $\text{round}(z, 2) * 10^2$ . It is assigned whenever $z$ is updated by the volume $\text{round}(z, 2) * 10^2$ , if $\text{round}(z, 2) * 10^2$ is bigger/smaller than previously counted volume, where:<br><br><ul style="list-style-type: none"> <li><math>z</math> is the volume of CQI whenever CQI report is received when the SSB index used for the CQI report is group of subcounter.<i>SSB</i> and when the CQI table of the CQI report is group of subcounter.<i>CQITable</i>.</li> </ul> | +| Measurement Result | CQI/ $10^2$ (S16) | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Type | OR.DLSQL.WidebandCqiFR2. <i>SSB</i> . <i>CQITable</i> . <i>statistic</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63<br><i>CQITable</i> is the CQI table:<br>0: table 1<br>1: table 2<br><i>statistic</i> is<br>0: average<br>1: maximum<br>2: minimum | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DLSQL.PdcchTxPower | +| Description | This counter measures the following $x$ and provides $\text{round}(x, 2) \cdot 10^2$ . $x$ is the statistics of transmission power determined by outer-loop TPC of UE specific PDCCH. If PDCCH is transmitted within some OFDM symbols with same SSB in one slot, this counter counts 1 sample and calculates power as linear average within OFDM symbols. If PDCCH is transmitted with different SSB each OFDM symbols in the one slot, this counter counts the PDCCH for each SSB, and doesn't calculate power as average within OFDM symbols.<br>It is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter of subcounter. <i>statistic</i> (avg.) is calculated by $\text{round}(x/y, 2) \cdot 10^2$ , where:<br><p><math>x</math> is incremented by the volume of transmission power of PDCCH whenever PDCCH is transmitted when SSB used for PDCCH is group of subcounter.<i>SSB</i> and when the DCI format of transmitted DCI is group of subcounter.<i>DCI</i>. If PDCCH is transmitted within plural OFDM symbols with same SSB in one slot, the volume is linear average within the OFDM symbols. If PDCCH is transmitted with different SSB in each OFDM symbols in the one slot, <math>x</math> is incremented for each one.</p> <p><math>y</math> is incremented by 1 whenever PDCCH is transmitted when SSB used for PDCCH is group of subcounter.<i>SSB</i> and when the DCI format of transmitted DCI is group of subcounter.<i>DCI</i>. If PDCCH is transmitted within plural OFDM symbols with same SSB in one slot, <math>y</math> is only incremented once per slot. If PDCCH is transmitted with different SSB in each OFDM symbols in the one slot, <math>y</math> is incremented once per OFDM symbol.</p> Measurement subcounter of subcounter. <i>statistic</i> (max/min) is maximum/minimum number of $\text{round}(z, 2) \cdot 10^2$ . It is assigned whenever $z$ is updated by the volume $\text{round}(z, 2) \cdot 10^2$ , if $\text{round}(z, 2) \cdot 10^2$ is bigger/smaller than previously counted volume, where:<br><p><math>z</math> is the volume of transmission power of PDCCH whenever PDCCH is transmitted when SSB used for PDCCH is group of</p> | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | subcounter. <i>SSB</i> and when the DCI format of transmitted DCI is group of subcounter. <i>DCI</i> . If PDCCH is transmitted within plural OFDM symbols with same SSB in one slot, the volume is linear average within OFDM symbols. If PDCCH is transmitted with different SSB in each OFDM symbols in the one slot, <i>z</i> is once per OFDM symbol. | +| Measurement Result | dBm/10 <sup>2</sup> (S16) | +| Measurement Type | OR.DLSQL.PdcchTxPower. <i>SSB.DCI.statistic</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63<br><i>DCI</i> is the DCI format:<br>0: 0_0<br>1: 0_1<br>2: 1_0<br>3: 1_1<br><i>statistic</i> is<br>0: average<br>1: maximum<br>2: minimum | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.8 NR Beamforming performance counters + +### A.8.1 Distribution of UEs per beam index + +#### A.8.1.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.BF.DistUeBeamIndex | +| Description | This counter provides distribution of the UEs with beam index. This counter obtains the number of the UEs every 100 ms. This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UEs per SSB index of the UE: #0, #1, ..., #63 as subcounter. <i>SSB</i> . The number is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.BF.DistUeBeamIndex. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>..<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.8.2 Best and Second Best Beam distribution + +### A.8.2.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.BF.BestSecondBestBeamDist | +| Description | This counter provides the distribution of Best and Second best beams.<br>This counter is only updated when number of SSB is 8 or less.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UEs per the best and second best SSB index of the UE: best beam #0 and second beam #0, best beam #1 and second beam #0, ..., best beam#7 and second beam#7 as subcounter. <i>binX</i> .<br>The value for a given bin shall be incremented when either best or second best beam is changed for any reason. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.BF.BestSecondBestBeamDist. <i>binX</i> where<br><i>Bin1</i> is best beam #0 and second beam #0.<br><i>Bin2</i> is best beam #1 and second beam #0.<br>:<br><i>BinX</i> is best beam #a and second beam #b. :X = a+8b+1<br>:<br><i>Bin64</i> is best beam#7 and second beam#7. | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.8.3 UE reported differential L1-RSRP of second best beam + +### A.8.3.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.BF.UeReportedDisffL1RsrpSecondBestBeam | +| Description | This counter provides the distribution of the UE reported differential L1-RSRP of second best beam.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever L1-RSRP report is received when the differential L1-RSRP of second best beam is group of subcounter.bin. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.BF.UeReportedDisffL1RsrpSecondBestBeam. <i>binX</i> where <i>binX</i> corresponds to the UE reported differential L1-RSRP, x, of second best beam<br>Bin1: $0 \leq x < 2$ dB<br>Bin2: $2\text{ dB} \leq x < 4$ dB<br>...<br>Bin16: $30\text{ dB} \leq x$ | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.9 NR RACH Usage performance counters + +### A.9.1 Received preambles in group A + +#### A.9.1.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RACH.RxPreamblesGroupA | +| Description | This counter provides the number of the received random preambles of group A.<br>This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever random preamble of group A is received when the SSB which is used for preamble transmission is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RACH.RxPreamblesGroupA. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.9.2 The number of received dedicated preamble + +#### A.9.2.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RACH.NumRxDedictedPreamble | +| Description | This counter provides the number of the received dedicated preambles.<br>This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever dedicated preamble is received when the SSB which is used for preamble transmission is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RACH.NumRxDedictedPreamble. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.9.3 Transmitted RARs for preamble in group A + +#### A.9.3.1 Performance Counter Table + +| | | +|------------------|-----------------------------------------------------------------------------------| +| Measurement Name | OR.RACH.TxRarPreambleGroupA | +| Description | This counter provides the number of the transmitted RAR for preambles of group A. | + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RAR for preamble of group A is transmitted when the SSB which is used for RAR transmission is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RACH.TxRarPreambleGroupA. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.9.4 Transmitted RARs for dedicated preamble + +### A.9.4.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RACH.TxRarDedicatedPreamble | +| Description | This counter provides the number of the transmitted RAR for dedicated preambles.<br>This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RAR for dedicated preamble is transmitted when the SSB which is used for RAR transmission is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RACH.TxRarDedicatedPreamble. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.9.5 Failures at assignment of dedicated preamble + +### A.9.5.1 Performance Counter Table + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RACH.FailAssignmentDedicatedPreamble | +| Description | This counter provides the number indicating use of random preamble due to NG of dedicated preamble delivery.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RA procedure using random preamble is triggered due to NG of dedicated preamble assignment when the SSB which is used for random preamble transmission is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.RACH.FailAssignmentDedicatedPreamble. <i>SSB</i> where <i>SSB</i> is the SSB index: | + +| | | +|--------------------------|--------------------------------------------------| +| | 0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.9.6 Occasions for dedicated preamble reception + +### A.9.6.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RACH.OccasionDedicatedPreambleRx | +| Description | This counter provides the number of the occasions for dedicated preamble. If multiple dedicated preambles are assigned, this counter calculated as the number of assigned preambles.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of assigned preambles whenever dedicated preamble(s) are expected to be received when the SSB which is used for random preamble transmission is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.RACH.OccasionDedicatedPreambleRx. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.9.7 Failures at assignment of a dedicated preamble for PDCCH order RA (UL out-of-sync) + +### A.9.7.1 Performance Counter Table + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RACH.FailAssignmentDedicatedPreamblePdcchOrderRaUIOutSync | +| Description | This counter provides the number of failures at assignment of a dedicated preamble when the gNB detects UL out-of-sync and tries CFRA operation (PDCCH order) to recover UL link connection.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever a failure at assignment of a dedicated preamble is occurred due to UL out-of-sync when the SSB used for assignment of a dedicated preamble is group of subcounter. <i>SSB</i> . | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.RACH.FailAssignmentDedicatedPreamblePdcchOrderRaUIOutSync. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1 | + +| | | +|--------------------------|--------------------------------------------------| +| | ... | +| | 63: #63 | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.10 NR Timing Advance performance counters + +### A.10.1 Distribution of $N_{TA}$ value of RAR message + +#### A.10.1.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.TA.DistNtaRarMessage | +| Description | This counter provides the distributions of RARs with the bin of $N_{TA}$ value described the following. The bin type is selected corresponding to CellSize.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever RAR is transmitted when the SSB index used for the RAR is group of subcounter. <i>SSB</i> and when the $N_{TA}$ is group of subcounter. <i>binX</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.TA.DistNtaRarMessage. <i>SSB.binX</i> where<br><i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>..<br>63: #63<br><i>binX</i> depends on cellSize below:<br>CellSize = <i>large</i> :<br>bin1: $0 \le N_{TA} < 72765$<br>bin2: $72765 \le N_{TA} < 145530$<br>...<br>bin10: $654885 \le N_{TA}$<br>CellSize = <i>middle</i> :<br>bin1: $0 \le N_{TA} < 29106$<br>bin2: $29106 \le N_{TA} < 58212$<br>...<br>bin10: $261954 \le N_{TA}$<br>CellSize = <i>small</i> :<br>bin1: $0 \le N_{TA} < 728$<br>bin2: $728 \le N_{TA} < 1456$<br>...<br>bin10: $6552 \le N_{TA}$<br>CellSize = <i>Very small</i> :<br>Reserved | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11 NR Cell Utilization performance counters (Type A) + +### A.11.1 Slots at which PDCCH resource shortage occurred + +#### A.11.1.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.SlotPdcchResourceShortageOccurred | +| Description | This counter provides the number of the slots when PDCCH shortage occurred.<br>This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 at every slot in which CCE resource shortage restricts the multiplexing number of PDCCH at least once. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.SlotPdcchResourceShortageOccurred | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.11.2 Canceled DCI due to PDCCH resource shortage + +#### A.11.2.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.CancelDciPdcchResourceShortage | +| Description | This counter provides the number of the cancels of DCI transmission due to PDCCH resource shortage.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of DCI which is canceled due to CCE resource shortage whenever CCE resource shortage restricts the multiplexing number of PDCCH. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.CancelDciPdcchResourceShortage | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +### A.11.3 Maximum UEs buffering UL/DL data + +#### A.11.3.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MaxUeBufferULDLData | +| Description | This counter obtains the number of UEs buffering UL/DL data every 100 ms and provides the maximum number of each 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.<br>x is the number of the UEs which have UL and/or DL data which is group of subcounter. <i>Pmgroup</i> . x is acquired as an instantaneous value at | + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------| +| | every 100ms. Note: multiple 5QIs can be set per UE, each 5QI is counted per QoS flow. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.MaxUeBufferUlData. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.11.4 Maximum UEs buffering UL data + +### 3 A.11.4.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MaxUeBufferUlData | +| Description | This counter obtains the number of UEs buffering UL data every 100 ms and provides the maximum number of each 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.<br>x is the number of UEs which has UL data with subcounter. <i>Pmgroup</i> . x is and is acquired as an instantaneous value at every 100ms. Note: multiple 5QIs can be set per UE, each 5QI is counted per QoS flow. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.MaxUeBufferUlData. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## 5 A.11.5 Maximum UEs buffering DL data + +### 6 A.11.5.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MaxUeBufferDlData | +| Description | This counter obtains the number of UEs buffering DL data every 100 ms and provides the maximum number of each 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume. | + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | x is the number of UEs which has DL data with subcounter. <i>Pmgroup</i> . x is acquired as an instantaneous value at every 100ms. Note: multiple 5QIs can be set per UE, each 5QI is counted per QoS flow. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.MaxUeBufferDLData. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.11.6 Multiplexed transmissions of PUSCH + +### 3 A.11.6.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MultiplexTxPusch | +| Description | This counter provides the accumulated number of the multiplication number of PUSCH.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 at every slot in which PDSCH is recieved when the multiplexed number in frequency domain is group of subcounter. <i>mux</i> . | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.MultiplexTxPusch. <i>mux</i> where <i>mux</i> is the number of multiplex:<br>0: 1 multiplex<br>1: 2 multiplex to 5 multiplex<br>2: 6 multiplex to 12 multiplex<br>3: more than 12 multiplex | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## 5 A.11.7 Multiplexed receptions of PDSCH + +### 6 A.11.7.1 Performance Counter Table + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MultiplexRxPdsch | +| Description | This counter provides the accumulated number of the multiplication number of PDSCH.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 when PDSCH is recieved when the multiplexed number in frequency domain is group of subcounter. <i>mux</i> . | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.MultiplexRxPdsch. <i>mux</i> where <i>mux</i> is the number of multiplex:<br>0: 1 multiplex | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------| +| | 1: 2 multiplex to 5 multiplex<br>2: 6 multiplex to 12 multiplex<br>3: more than 12 multiplex | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.8 Maximum DRX inactive UEs + +### A.11.8.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MaxDrxInactiveUe | +| Description | This counter obtains the number of UEs configured as DRX inactive every 100 ms and provides the maximum number of each 100 ms. This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.<br>x is the number of UEs of which <i>drx-InactivityTimer</i> is assumed to be running. x is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.MaxDrxInactiveUe | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.9 Maximum DRX active UEs + +### A.11.9.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MaxDrxActiveUe | +| Description | This counter obtains the number of UEs configured as DRX active every 100 ms and provides the maximum number of each 100 ms. This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.<br>x is the number of UEs which is configured <i>drx-config</i> and of which <i>drx-InactivityTimer</i> is assumed not to be running. x is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.MaxDrxActiveUe | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.10 Distribution of trafficInactivityTimer + +### A.11.10.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.DistTrafficInactiveTimer | +| Description | This counter provides the distribution of the UEs whose trafficInactivityTimer is running with 1 s bin of the trafficInactivityTimer. trafficInactivityTimer measures the consecutive time when no UL/DL data for the UE is available. This counter obtains the number of UEs every 1 m.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of UEs whose trafficInactivityTimer is in the value of the subcounter. <i>binX</i> .<br>The number is acquired as an instantaneous value at every 1 minutes. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.DistTrafficInactiveTimer. <i>binX</i> where<br>bin 1: $0\text{ s} \le \text{trafficInactivityTimer} < 1\text{ s}$<br>bin 2: $1\text{ s} \le \text{trafficInactivityTimer} < 2\text{ s}$<br>bin 3: $2\text{ s} \le \text{trafficInactivityTimer} < 4\text{ s}$<br>bin 4: $4\text{ s} \le \text{trafficInactivityTimer} < 8\text{ s}$<br>bin 5: $8\text{ s} \le \text{trafficInactivityTimer} < 16\text{ s}$<br>bin 6: $16\text{ s} \le \text{trafficInactivityTimer} < 32\text{ s}$<br>bin 7: $32\text{ s} \le \text{trafficInactivityTimer} < 64\text{ s}$<br>bin 8: $64\text{ s} \le \text{trafficInactivityTimer} < 128\text{ s}$<br>bin 9: $128\text{ s} \le \text{trafficInactivityTimer}$ | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.11 Slots in which scheduler assigned as mini slot + +### A.11.11.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.SlotSchedulerAssignMiniSlot | +| Description | This counter provides the number of slots with mini slot scheduling. This counter is for FR2.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 at every slot in which PDSCH which is multiplexed in time domain in a slot is assigned. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.SlotSchedulerAssignMiniSlot | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.12 Mini slots in which PUSCH was received + +### A.11.12.1 Performance Counter Table + +| | | +|------------------|----------------------------| +| Measurement Name | OR.CellUA.MiniSlotsPuschRx | +|------------------|----------------------------| + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------| +| Description | This counter provides the number of mini slots when PUSCH is received.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 when PUSCH which is multiplexed in time domain in a slot is assigned. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.MiniSlotsPuschRx | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.13 UEs in the cell using this cell as PSCell or having activated SCell in DL + +### A.11.13.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.UeCellPscellActiveScellDI | +| Description | This counter provides the accumulated number of the UEs in the cell using this cell as PSCell or having activated SCell in DL. This counter obtains the number of the UEs every 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UEs which using this cell as PSCell or activate SCell in DL.<br>The number is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.UeCellPscellActiveScellDI | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.14 UEs in the cell using this cell as PSCell or having activated SCell in UL + +### A.11.14.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.UeCellPscellActiveScellUI | +| Description | This counter provides the accumulated number of the UEs in the cell using this cell as PSCell or having activated SCell in UL. This counter obtains the number of the UEs every 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UEs which using this cell as PSCell or activate SCell in UL.<br>The number is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.UeCellPscellActiveScellUI | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.15 Distribution of PSCell UEs with X activated SCells in UL + +### A.11.15.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.DistPscellUeXactiveScellUl | +| Description | This counter provides the distribution of the PSCell UE with the number of activated SCell in UL. This counter obtains the number of the UEs every 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UE configured this cell as PSCell per the number of activated SCell in UL: 1 active SCell,, 2 active SCell, ..., 31 active SCell as subcounter. <i>SCell</i> .<br>The number is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.DistPscellUeXactiveScellUl. <i>NumScell</i> where <i>NumScell</i> is the number of active SCell:<br>0: 1 active SCell<br>1: 2 active SCell<br>...<br>30: 31 active SCell | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.16 Distribution of PSCell UEs with X activated SCells in DL + +### A.11.16.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.DistPscellUeXactiveScellDl | +| Description | This counter provides the distribution of the PSCell UEs with the number of activated SCell in DL. This counter obtains the number of the UEs every 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UE configured this cell as PSCell per the number of activated SCell in DL: 1 active SCell,, 2 active SCell, ..., 31 active SCell as subcounter. <i>SCell</i> .<br>The number is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.DistPscellUeXactiveScellDl. <i>NumScell</i> where <i>NumScell</i> is the number of active SCell:<br>0: 1 active SCell<br>1: 2 active SCell<br>...<br>30: 31 active SCell | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.17 Maximum amount of PSCell UEs (UL) + +### A.11.17.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MaxPscellUeUl | +| Description | This counter obtains the number of the PSCell UEs for UL every 100 ms and provides the maximum number of each 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.<br>x is the number of UE configured this cell as PSCell per the number of activated SCell in UL: 1 active SCell, 2 active SCell, ..., 31 active SCell as subcounter. <i>SCell</i> . x is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.MaxPscellUeUl. <i>NumScell</i> where <i>NumScell</i> is the number of active SCell:<br>0: 1 active SCell<br>1: 2 active SCell<br>...<br>30: 31 active SCell | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.18 Minimum amount of PSCell UEs (UL) + +### A.11.18.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MinPscellUeUl | +| Description | This counter obtains the number of the PSCell UEs for UL every 100 ms and provides the minimum number of each 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the minimum number of x. It is assigned with period of 100ms by the volume x, if x is smaller than previously counted volume.<br>x is the number of the UE configured this cell as PSCell per the number of activated SCell in UL: 1 active SCell, 2 active SCell, ..., 31 active SCell as subcounter. <i>SCell</i> . x is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.MinPscellUeUl. <i>NumScell</i> where <i>NumScell</i> is the number of active SCell:<br>0: 1 active SCell<br>1: 2 active SCell<br>...<br>30: 31 active SCell | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.19 Maximum amount of PSCell UEs (DL) + +### A.11.19.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MaxPscellUeDl | +| Description | This counter obtains the number of the PSCell UEs for DL every 100 ms and provides the maximum number of each 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.<br>x is the number of the UE configured this cell as PSCell per the number of activated SCell in DL: 1 active SCell, 2 active SCell, ..., 31 active SCell as subcounter.SCell. x is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.MaxPscellUeDl.NumScell where NumScell is the number of active SCell:<br>0: 1 active SCell<br>1: 2 active SCell<br>...<br>30: 31 active SCell | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.20 Minimum amount of PSCell UEs (DL) + +### A.11.20.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MinPscellUeDl | +| Description | This counter obtains the number of the PSCell UEs for DL every 100 ms and provides the minimum number of each 100 ms.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the minimum number of x. It is assigned with period of 100ms by the volume x, if x is smaller than previously counted volume.<br>x is the number of the UE configured this cell as PSCell per the number of activated SCell in DL: 1 active SCell, 2 active SCell, ..., 31 active SCell as subcounter.SCell. x is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.MinPscellUeDl.NumScell where NumScell is the number of active SCell:<br>0: 1 active SCell<br>1: 2 active SCell<br>...<br>30: 31 active SCell | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.21 Activation/Deactivation MAC CE (SCell Active) + +### A.11.21.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.ActDeactMacCeScellAct | +| Description | This counter provides the number of the Activation/Deactivation MAC CEs transmitted for SCell activation.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the incremented by 1 whenever Activation/Deactivation MAC CEs is transmitted for SCell activation. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.ActDeactMacCeScellAct | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.22 Activation/Deactivation MAC CE (SCell Deactive) + +### A.11.22.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.ActDeactMacCeScellDeact | +| Description | This counter provides the number of the Activation/Deactivation MAC CEs transmitted for SCell deactivation. If Activation/Deactivation MAC CE isn't transmitted when sCellDeactivationTimer expires, this counter includes the number of sCellDeactivationTimer expiry.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is the incremented by 1 whenever Activation/Deactivation MAC CEs is transmitted for SCell deactivation or whenever sCellDeactivationTimer managed at O-DU expires. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellUA.ActDeactMacCeScellDeact | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.23 Distribution of DL Total PRB Usage + +### A.11.23.1 Performance Counter Table + +| | | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | RRU.PrbTotDlDist.BinX | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.3<br><br><u>O-RAN addition:</u><br>Averaging is done over a time period $t_n$ of 1s.<br><br>bin 1: $0 \% \leq \text{PRB usage} < 5 \%$<br>bin 2: $5 \% \leq \text{PRB usage} < 10 \%$<br>bin 3: $10 \% \leq \text{PRB usage} < 15 \%$<br>bin 4: $15 \% \leq \text{PRB usage} < 20 \%$<br>bin 5: $20 \% \leq \text{PRB usage} < 25 \%$<br>bin 6: $25 \% \leq \text{PRB usage} < 30 \%$ | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | bin 7: 30 % $\leq$ PRB usage < 35 %<br>bin 8: 35 % $\leq$ PRB usage < 40 %<br>bin 9: 40 % $\leq$ PRB usage < 45 %<br>bin 10: 45 % $\leq$ PRB usage < 50 %<br>bin 11: 50 % $\leq$ PRB usage < 55 %<br>bin 12: 55 % $\leq$ PRB usage < 60 %<br>bin 13: 60 % $\leq$ PRB usage < 65 %<br>bin 14: 65 % $\leq$ PRB usage < 70 %<br>bin 15: 70 % $\leq$ PRB usage < 75 %<br>bin 16: 75 % $\leq$ PRB usage < 80 %<br>bin 17: 80 % $\leq$ PRB usage < 85 %<br>bin 18: 85 % $\leq$ PRB usage < 90 %<br>bin 19: 90 % $\leq$ PRB usage < 95 %<br>bin 20: 95 % $\leq$ PRB usage < 100 %<br>This is recommended to support for O-DU.<br>The counter is split into subcounters per S-NSSAI. The counter is recommended when related slice feature is supported. | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.3 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.3<br><br><u>O-RAN addition:</u><br>Averaging is done over a time period $t_n$ of 1s and the bin defined in description should be used.<br>If S-NSSAI subcounter is maintained, the number of measurements is accumulated per the number of supported S-NSSAI. | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.3 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.3<br><br><u>O-RAN addition:</u><br>Subcounter<br>OR.RRU.PrbTotDlDist.BinX. <i>SNSSAI</i> , where <i>SNSSAI</i> identifies the S-NSSAI. | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.3 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.3 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.3 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.3 | + +## A.11.24 Distribution of UL Total PRB Usage + +### A.11.24.1 Performance Counter Table + +| | | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | RRU.PrbTotUlDist.BinX | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.4<br><br><u>O-RAN addition:</u><br>Averaging is done over a time period $t_n$ of 1s.<br><br>bin 1: 0 % $\leq$ PRB usage < 5 %<br>bin 2: 5 % $\leq$ PRB usage < 10 %<br>bin 3: 10 % $\leq$ PRB usage < 15 %<br>bin 4: 15 % $\leq$ PRB usage < 20 %<br>bin 5: 20 % $\leq$ PRB usage < 25 %<br>bin 6: 25 % $\leq$ PRB usage < 30 %<br>bin 7: 30 % $\leq$ PRB usage < 35 %<br>bin 8: 35 % $\leq$ PRB usage < 40 %<br>bin 9: 40 % $\leq$ PRB usage < 45 %<br>bin 10: 45 % $\leq$ PRB usage < 50 %<br>bin 11: 50 % $\leq$ PRB usage < 55 % | + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | bin 12: $55 \% \leq \text{PRB usage} < 60 \%$<br>bin 13: $60 \% \leq \text{PRB usage} < 65 \%$<br>bin 14: $65 \% \leq \text{PRB usage} < 70 \%$<br>bin 15: $70 \% \leq \text{PRB usage} < 75 \%$<br>bin 16: $75 \% \leq \text{PRB usage} < 80 \%$<br>bin 17: $80 \% \leq \text{PRB usage} < 85 \%$<br>bin 18: $85 \% \leq \text{PRB usage} < 90 \%$<br>bin 19: $90 \% \leq \text{PRB usage} < 95 \%$<br>bin 20: $95 \% \leq \text{PRB usage} < 100 \%$<br>This is recommended to support for O-DU.<br>The counter is split into subcounters per S-NSSAI. The counter is recommended when related slice feature is supported. | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.4 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.4<br><br><u>O-RAN addition:</u><br>Averaging is done over a time period $t_n$ of 1s and the bin defined in description should be used.<br>If S-NSSAI subcounter is maintained, the number of measurements is accumulated per the number of supported S-NSSAI. | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.4 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.4<br><br><u>O-RAN addition:</u><br>Subcounter<br>OR.RRU.PrbTotUIDist.BinX. <i>SNSSAI</i> , where SNSSAI identifies the S-NSSAI. | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.4 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.4 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.4 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.4 | + +## A.11.25 Average DL Cell throughput + +### A.11.25.1 Performance Counter Table + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.AveDlCellThroughput | +| Description | This counter provides the Average DL Cell throughput of MAC. This counter is obtained by accumulating the MAC level volume of a data, and then dividing by the scheduled time per cell. The measurement is performed at the MAC level. This measurement can be split into subcounters per supported S-NSSAI.<br>This is optional counter for O-DU.<br>The counter is split into subcounters per S-NSSAI. The counter is recommended when related slice feature is supported. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is calculated by $x/y$ .<br>$x$ is incremented by the volume of DL MAC PDU whenever the successfully delivery of DL MAC PDU is confirmed.<br>$y$ is incremented by the transmission period (e.g. 0.5ms or 0.125ms) for the PDU whenever DL MAC PDU is transmitted (i.e. including HARQ retransmission).<br>If S-NSSAI subcounter is maintained, the number of measurements is accumulated per the number of supported S-NSSAI. | +| Measurement Result | kbps (U32) | +| Measurement Type | OR.CellUA.AveDlCellThroughput or<br>OR.CellUA.AveDlCellThroughput. <i>SNSSAI</i> , where SNSSAI identifies the S-NSSAI. | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.26 Average UL Cell throughput + +### A.11.26.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.AveUlCellThroughput | +| Description | <p>This counter provides the Average UL Cell throughput of MAC. This counter is obtained by accumulating the MAC level volume of a data, and then dividing by the scheduled time per cell. The measurement is performed at the MAC level. This measurement can be split into subcounters per S-NSSAI.</p> <p>This is optional counter for O-DU.</p> <p>The counter is split into subcounters per S-NSSAI. The counter is recommended when related slice feature is supported.</p> | +| Collection Method | SI (Status Inspection) | +| Condition | <p>Measurement subcounter is calculated by <math>x/y</math>.</p> <p><math>x</math> is incremented by the volume of UL MAC PDU whenever UL MAC PDU is successfully received.</p> <p><math>y</math> is incremented by the transmission period whenever the UL MAC PDU is received (i.e. including HARQ retransmission) .</p> <p>If S-NSSAI subcounter is maintained, the number of measurements is accumulated per the number of supported S-NSSAI.</p> | +| Measurement Result | kbps (U32) | +| Measurement Type | OR.CellUA.AveUlCellThroughput or<br>OR.CellUA.AveUlCellThroughput. <i>SNSSAI</i> , where SNSSAI identifies the S-NSSAI. | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.27 Average DL Beam throughput + +### A.11.27.1 Performance Counter Table + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.AveDlBeamThroughput | +| Description | <p>This counter provides the Average DL Beam throughput of MAC. This counter is obtained by accumulating the MAC level volume of a data, and then dividing by the scheduled time per SSB index. The measurement is performed at the MAC level.</p> <p>This is optional counter for O-DU.</p> | +| Collection Method | SI (Status Inspection) | +| Condition | <p>Measurement subcounter is calculated by <math>x/y</math>.</p> <p><math>x</math> is incremented by the volume of DL MAC PDU whenever DL MAC PDU is confirmed the successfully delivery when the SSB used for PDSCH is the group of subcounter.<i>SSB</i>.</p> <p><math>y</math> is incremented by the transmission period whenever the DL MAC PDU is transmitted (i.e. including HARQ retransmission) when the SSB used for PDSCH is the group of subcounter.<i>SSB</i>..</p> | +| Measurement Result | kbps (U32) | +| Measurement Type | OR.CellUA.AveDlBeamThroughput. <i>SSB</i> where <i>SSB</i> is the SSB index: | + +| | | +|--------------------------|--------------------------------------------------| +| | 0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +1 + +## 2 A.11.28 Average UL Beam throughput + +### 3 A.11.28.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.AveUIBeamThroughput | +| Description | This counter provides the Average UL Beam throughput of MAC. This counter is obtained by accumulating the MAC level volume of a data, and then dividing by the scheduled time per SSB index. The measurement is performed at the MAC level.<br>This is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is calculated by $x/y$ .<br>$x$ is incremented by the volume of UL MAC PDU whenever UL MAC PDU is successfully received when the SSB used for PUSCH is the group of subcounter. <i>SSB</i> ..<br>$y$ is incremented by the transmission period whenever the UL MAC PDU is received (i.e. including HARQ retransmission) when the SSB used for PUSCH is the group of subcounter. <i>SSB</i> . | +| Measurement Result | kbps (U32) | +| Measurement Type | OR.CellUA.AveUIBeamThroughput. <i>SSB</i> where <i>SSB</i> is the SSB index:<br>0: #0<br>1: #1<br>...<br>63: #63 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +4 + +## 5 A.11.29 Average DL active DRB + +### 6 A.11.29.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.AveDlActDrb | +| Description | This counter provides the average number of DL active DRB. This counter is obtained by averaging the number of the active DRB which has data in MAC/RLC buffer during measurement time per cell.<br>This is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is calculated by $x/y$ .<br>$x$ is incremented by the number of the DRB which has DL data in MAC/RLC buffer at every 100 ms.<br>$y$ is calculated by measurement period divided by 100 ms. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.AveDlActDrb | +| Measurement Object Class | NRCelIDU | + +| | | +|----------------------|--------------------------------------------------| +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.30 Maximum DL active DRB + +### A.11.30.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUA.MaxDLActDrb | +| Description | This counter provides the maximum number of DL active DRB. This counter is obtained by providing the maximum number of the active DRB which has data in MAC/RLC buffer during measurement time per cell.<br>This is optional counter for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is the maximum number of x. It is assigned with period of 100ms by the volume x, if x is bigger than previously counted volume.<br>x is the number of the DRB which has DL data in MAC/RLC buffer. x is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUA.MaxDLActDrb | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.31 Mean DL PRB used for data traffic + +### A.11.31.1 Performance Counter Table + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRU.PrbUsedDL | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.5<br><br><u>O-RAN addition:</u><br>The split into subcounters per S-NSSAI is recommended when the Slicing feature is supported.<br>The counter is split into subcounter of subcounter per PmCountGroup. | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.5 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.5<br><br><u>O-RAN addition:</u><br>S-NSSAI subcounter is maintained, the number of measurements is counted per the number of supported S-NSSAI. If related slice feature is not supported, only the S-NSSAI #0 is used.<br>PmCountGroup subcounter of subcounter is maintained, the number of measurements is counted per the number of supported PmCountGroup. | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.5 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.5<br><br><u>O-RAN addition:</u><br>OR.RRU.PrbUsedDL.SNSSAI.PmGroup, where SNSSAI is S-NSSAI.<br>PmGroup is PmCountGroup number:<br>0: #0<br>1: #1 | + +| | | +|--------------------------|-----------------------------------------------| +| | ...<br>19: #19 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.5 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.5 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.5 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.5 | + +## A.11.32 Mean UL PRB used for data traffic + +### A.11.32.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.RRU.PrbUsedUl | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.7<br><br><u>O-RAN addition:</u><br>The split into subcounters per S-NSSAI is recommended when the Slicing feature is supported.<br>The counter is split into subcounter of subcounter per PmCountGroup. | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.7 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.7<br><br><u>O-RAN addition:</u><br>S-NSSAI subcounter is maintained, the number of measurements is counted per the number of supported S-NSSAI. If related slice feature is not supported, only the S-NSSAI #0 is used.<br>PmCountGroup subcounter of subcounter is maintained, the number of measurements is counted per the number of supported PmCountGroup. | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.7 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.7<br><br><u>O-RAN addition:</u><br>OR.RRU.PrbUsedUl.SNSSAI.PmGroup, where <i>SNSSAI</i> is S-NSSAI.<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.7 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.7 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.7 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.2.7 | + +## A.11.33 Distribution of UL UE throughput in gNB + +### A.11.33.1 Performance Counter Table + +| | | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DRB.UEThpUIDist.Bin | +| Description | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4<br><br><u>O-RAN addition:</u><br>The split into subcounters per S-NSSAI is recommended when the Slicing feature is supported. The split into subcounter of subcounter per PmCountGroup.<br>The reference measurement time T for calculating the throughput of each UE is 1000ms. | + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>The bins corresponding to the UL throughput experienced by the UE is defined as follow.</p> <p>bin 1: <math>0 \leq \text{UL UE throughput} < 0.05 \times \text{Throughput}</math></p> <p>bin 2: <math>0.05 \times \text{Throughput} \leq \text{UL UE throughput} < 0.1 \times \text{Throughput}</math></p> <p>bin 3: <math>0.1 \times \text{Throughput} \leq \text{UL UE throughput} < 0.15 \times \text{Throughput}</math></p> <p>bin 4: <math>0.15 \times \text{Throughput} \leq \text{UL UE throughput} < 0.2 \times \text{Throughput}</math></p> <p>bin 5: <math>0.2 \times \text{Throughput} \leq \text{UL UE throughput} < 0.25 \times \text{Throughput}</math></p> <p>bin 6: <math>0.25 \times \text{Throughput} \leq \text{UL UE throughput} < 0.3 \times \text{Throughput}</math></p> <p>bin 7: <math>0.3 \times \text{Throughput} \leq \text{UL UE throughput} < 0.35 \times \text{Throughput}</math></p> <p>bin 8: <math>0.35 \times \text{Throughput} \leq \text{UL UE throughput} < 0.4 \times \text{Throughput}</math></p> <p>bin 9: <math>0.4 \times \text{Throughput} \leq \text{UL UE throughput} < 0.45 \times \text{Throughput}</math></p> <p>bin 10: <math>0.45 \times \text{Throughput} \leq \text{UL UE throughput} < 0.5 \times \text{Throughput}</math></p> <p>bin 11: <math>0.5 \times \text{Throughput} \leq \text{UL UE throughput} < 0.55 \times \text{Throughput}</math></p> <p>bin 12: <math>0.55 \times \text{Throughput} \leq \text{UL UE throughput} < 0.6 \times \text{Throughput}</math></p> <p>bin 13: <math>0.6 \times \text{Throughput} \leq \text{UL UE throughput} < 0.65 \times \text{Throughput}</math></p> <p>bin 14: <math>0.65 \times \text{Throughput} \leq \text{UL UE throughput} < 0.7 \times \text{Throughput}</math></p> <p>bin 15: <math>0.7 \times \text{Throughput} \leq \text{UL UE throughput} < 0.75 \times \text{Throughput}</math></p> <p>bin 16: <math>0.75 \times \text{Throughput} \leq \text{UL UE throughput} < 0.8 \times \text{Throughput}</math></p> <p>bin 17: <math>0.8 \times \text{Throughput} \leq \text{UL UE throughput} < 0.85 \times \text{Throughput}</math></p> <p>bin 18: <math>0.85 \times \text{Throughput} \leq \text{UL UE throughput} < 0.9 \times \text{Throughput}</math></p> <p>bin 19: <math>0.9 \times \text{Throughput} \leq \text{UL UE throughput} < 0.95 \times \text{Throughput}</math></p> <p>bin 20: <math>0.95 \times \text{Throughput} \leq \text{UL UE throughput} < \text{Throughput}</math></p> <p>*Throughput is a predefined value in the implementation<br/>This is recommended to support for O-DU.</p> | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | +| Condition | <p>Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4</p> <p><u>O-RAN addition:</u><br/>The per UE throughput is calculated by the following formula. And the bin defined in description should be used.</p> <p>If <math>\Sigma \text{ThpTimeUL} > 0</math>, <math>\frac{\Sigma \text{ThpVolUL}}{\Sigma \text{ThpTimeUL}} \times 1000 [\text{kbits/s}]</math><br/>If <math>\Sigma \text{ThpTimeUL} = 0</math>, <math>0 [\text{kbit/s}]</math></p> <p>S-NSSAI subcounter is maintained, the number of measurements is counted per the number of supported S-NSSAI. If related slice feature is not supported, only the S-NSSAI #0 is used.<br/>PmCountGroup subcounter of subcounter is maintained, the number of measurements is counted per the number of supported PmCountGroup.</p> | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | +| Measurement Type | <p>Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4</p> <p><u>O-RAN addition:</u><br/>OR.DRB.UEThpUIDist.Bin.<i>SNSSAI.PmGroup</i>, where <i>SNSSAI</i> is S-NSSAI.<br/><i>PmGroup</i> is PmCountGroup number:<br/>0: #0<br/>1: #1<br/>...<br/>19: #19</p> | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | + +| | | +|----------------------|-----------------------------------------------| +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | + +## A.11.34 Distribution of DL UE throughput in gNB + +### A.11.34.1 Performance Counter Table + +| | | +|-------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DRB.UEThpDlDist.Bin | +| Description | <p>Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2</p> <p><u>O-RAN addition:</u><br/>The split into subcounters per S-NSSAI is recommended when the Slicing feature is supported. The split into subcounter of subcounter per PmCountGroup.</p> <p>The reference measurement time T for calculating the throughput of each UE is 1000ms.<br/>The bins corresponding to the DL throughput experienced by the UE is defined as follow.</p> bin 1: $0 \le \text{DL UE throughput} < 0.05 \times \text{Throughput}$<br>bin 2: $0.05 \times \text{Throughput} \le \text{DL UE throughput} < 0.1 \times \text{Throughput}$<br>bin 3: $0.1 \times \text{Throughput} \le \text{DL UE throughput} < 0.15 \times \text{Throughput}$<br>bin 4: $0.15 \times \text{Throughput} \le \text{DL UE throughput} < 0.2 \times \text{Throughput}$<br>bin 5: $0.2 \times \text{Throughput} \le \text{DL UE throughput} < 0.25 \times \text{Throughput}$<br>bin 6: $0.25 \times \text{Throughput} \le \text{DL UE throughput} < 0.3 \times \text{Throughput}$<br>bin 7: $0.3 \times \text{Throughput} \le \text{DL UE throughput} < 0.35 \times \text{Throughput}$<br>bin 8: $0.35 \times \text{Throughput} \le \text{DL UE throughput} < 0.4 \times \text{Throughput}$<br>bin 9: $0.4 \times \text{Throughput} \le \text{DL UE throughput} < 0.45 \times \text{Throughput}$<br>bin 10: $0.45 \times \text{Throughput} \le \text{DL UE throughput} < 0.5 \times \text{Throughput}$<br>bin 11: $0.5 \times \text{Throughput} \le \text{DL UE throughput} < 0.55 \times \text{Throughput}$<br>bin 12: $0.55 \times \text{Throughput} \le \text{DL UE throughput} < 0.6 \times \text{Throughput}$<br>bin 13: $0.6 \times \text{Throughput} \le \text{DL UE throughput} < 0.65 \times \text{Throughput}$<br>bin 14: $0.65 \times \text{Throughput} \le \text{DL UE throughput} < 0.7 \times \text{Throughput}$<br>bin 15: $0.7 \times \text{Throughput} \le \text{DL UE throughput} < 0.75 \times \text{Throughput}$<br>bin 16: $0.75 \times \text{Throughput} \le \text{DL UE throughput} < 0.8 \times \text{Throughput}$<br>bin 17: $0.8 \times \text{Throughput} \le \text{DL UE throughput} < 0.85 \times \text{Throughput}$<br>bin 18: $0.85 \times \text{Throughput} \le \text{DL UE throughput} < 0.9 \times \text{Throughput}$<br>bin 19: $0.9 \times \text{Throughput} \le \text{DL UE throughput} < 0.95 \times \text{Throughput}$<br>bin 20: $0.95 \times \text{Throughput} \le \text{DL UE throughput} < \text{Throughput}$<br>*Throughput is a predefined value in the implementation<br>This is recommended to support for O-DU. | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | +| Condition | <p>Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2</p> <p><u>O-RAN addition:</u><br/>The per UE throughput is calculated by the following formula. And the bin defined in description should be used.</p> | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>If <math>\Sigma \text{ThpTimeDl} > 0, \frac{\Sigma \text{ThpVolDl}}{\Sigma \text{ThpTimeDl}} \times 1000 [\text{kbits/s}]</math></p> <p>If <math>\Sigma \text{ThpTimeDl} = 0, 0 [\text{kbit/s}]</math></p> <p>S-NSSAI subcounter is maintained, the number of measurements is counted per the number of supported S-NSSAI. If related slice feature is not supported, only the S-NSSAI #0 is used.</p> <p>PmCountGroup subcounter of subcounter is maintained, the number of measurements is counted per the number of supported PmCountGroup.</p> | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | +| Measurement Type | <p>Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2</p> <p><u>O-RAN addition:</u><br/> OR.DRB.UEThpDlDist.Bin.SNSSAI.PmGroup, where SNSSAI is S-NSSAI.<br/> PmGroup is PmCountGroup number:<br/> 0: #0<br/> 1: #1<br/> ...<br/> 19: #19</p> | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | + +1 + +## 2 A.11.35 Distribution of DL packet drop rate + +### 3 A.11.35.1 Performance Counter Table + +| | | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DRB.RlcPacketDropRateDlDist.Bin | +| Description | <p>This measurement provides distribution of UE's fraction of RLC SDU packets which are dropped on the downlink, due to high traffic load, traffic management etc, in the gNB-DU. Only user-plane traffic (DTCH) is considered. A dropped packet is one who context is removed from the gNB-DU without any part of it having been transmitted on the air interface.</p> <p>The counter is split into subcounters per S-NSSAI. The counter is recommended when related slice feature is supported.</p> <p>The counter is split into subcounter of subcounter per PmCountGroup.</p> <p>The reference measurement time T for calculating the packet drop rate of each UE is 1000ms.</p> <p>The bins corresponding to the DL packet drop rate experienced by the UE is defined as follow.</p> <p>bin 1: <math>0 \% \leq \text{DL Packet drop rate} < 5 \%</math><br/> bin 2: <math>5 \% \leq \text{DL Packet drop rate} < 10 \%</math><br/> bin 3: <math>10 \% \leq \text{DL Packet drop rate} < 15 \%</math><br/> bin 4: <math>15 \% \leq \text{DL Packet drop rate} < 20 \%</math><br/> bin 5: <math>20 \% \leq \text{DL Packet drop rate} < 25 \%</math><br/> bin 6: <math>25 \% \leq \text{DL Packet drop rate} < 30 \%</math><br/> bin 7: <math>30 \% \leq \text{DL Packet drop rate} < 35 \%</math><br/> bin 8: <math>35 \% \leq \text{DL Packet drop rate} < 40 \%</math><br/> bin 9: <math>40 \% \leq \text{DL Packet drop rate} < 45 \%</math><br/> bin 10: <math>45 \% \leq \text{DL Packet drop rate} < 50 \%</math><br/> bin 11: <math>50 \% \leq \text{DL Packet drop rate} < 55 \%</math><br/> bin 12: <math>55 \% \leq \text{DL Packet drop rate} < 60 \%</math><br/> bin 13: <math>60 \% \leq \text{DL Packet drop rate} < 65 \%</math><br/> bin 14: <math>65 \% \leq \text{DL Packet drop rate} < 70 \%</math><br/> bin 15: <math>70 \% \leq \text{DL Packet drop rate} < 75 \%</math><br/> bin 16: <math>75 \% \leq \text{DL Packet drop rate} < 80 \%</math></p> | + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | bin 17: $80 \% \leq \text{DL Packet drop rate} < 85 \%$<br>bin 18: $85 \% \leq \text{DL Packet drop rate} < 90 \%$<br>bin 19: $90 \% \leq \text{DL Packet drop rate} < 95 \%$<br>bin 20: $95 \% \leq \text{DL Packet drop rate} < 100 \%$ | +| Collection Method | SI (Status Inspection) | +| Condition | This measurement is obtained as: $1000000 * \text{Number of DL packets, for which no part has been transmitted over the air, of the data radio bearers for each UE, that are discarded in the gNB-DU divided by Number of DL packets for data radio bearers for each UE that were received from gNB-CU-UP.}$ Then map packet drop rate to the bins according to their value and the thresholds of the bins and then provide an integer value of the number of samples in Bin<br>S-NSSAI subcounter is maintained, the number of measurements is accumulated per the number of supported S-NSSAI. If related slice feature is not supported, only the S-NSSAI #0 is used.<br>PmCountGroup subcounter of subcounter is maintained, the number of measurements is accumulated per the number of supported PmCountGroup. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.DRB.RlcPacketDropRateDist.Bin. <i>SNSSAI</i> . <i>PmGroup</i> , where <i>SNSSAI</i> is S-NSSAI.<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.36 PDCCH for BWP switching + +### A.11.36.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellA.PdcchBwpSwitch | +| Description | This measurement provides the total number of PDCCH for BWP switching. This measurement optionally is split into subcounters per BWP ID. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The measurement counter is incremented by 1 whenever PDCCH for BWP switching is triggered. This measurement counter shall not count retransmission.<br>If the optional BWP ID level subcounter measurements are performed, the number of measurements is equal to the number of BWP IDs to which the target BWP is to be switched. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellA.PdcchBwpSwitch or optionally<br>OR.CellA.PdcchBwpSwitch. <i>BWP</i> , where <i>BWP</i> is BWP ID. | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.37 Distribution of Activated BWP ID + +### A.11.37.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellA.DistActBwpId | +| Description | This measurement provides distribution of UEs for activated BWP. The measurement is split into subcounters per active BWP ID. This counter obtains the number of the UEs in certain period with recommended value 100ms. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UEs per active BWP ID. This measurement counter shall count UEs configured multiple BWPs and triggered BWP switching by PDCCH. (ex. Energy saving). The number of UEs is acquired as an instantaneous value in certain period with recommended value 100ms. | +| Measurement Result | Integer number (U16) | +| Measurement Type | OR.CellA.DistActBwpId. <i>BWP</i> , where <i>BWP</i> is BWP ID. | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.11.38 Non-linear Scale Distribution of UL UE throughput in gNB + +### A.11.38.1 Performance Counter Table + +| | | +|-------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DRB.UEThpULogDist.Bin | +| Description | <p>Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4</p> <p><u>O-RAN addition:</u><br/> The split into subcounter of subcounter per S-NSSAI is recommended when the Slicing feature is supported. The split into subcounters per PmCountGroup. The reference measurement time T for calculating the throughput of each UE is 1000ms.<br/> The bins corresponding to the UL throughput experienced by the UE is defined as follows.<br/> bin1: 0 kbps <= UL UE Throughput < 100 Kbps<br/> bin2: 100 Kbps <= UL UE Throughput < 200 Kbps<br/> bin3: 200 Kbps <= UL UE Throughput < 500 Kbps<br/> bin4: 500 Kbps <= UL UE Throughput < 1 Mbps<br/> bin5: 1 Mbps <= UL UE Throughput < 2 Mbps<br/> bin6: 2 Mbps <= UL UE Throughput < 5 Mbps<br/> bin7: 5 Mbps <= UL UE Throughput < 10 Mbps<br/> bin8: 10 Mbps <= UL UE Throughput < 20 Mbps<br/> bin9: 20 Mbps <= UL UE Throughput < 40 Mbps<br/> bin10: 40 Mbps <= UL UE Throughput < 60 Mbps<br/> bin11: 60 Mbps <= UL UE Throughput < 80 Mbps<br/> bin12: 80 Mbps <= UL UE Throughput < 100 Mbps<br/> bin13: 100 Mbps <= UL UE Throughput < 200 Mbps<br/> bin14: 200 Mbps <= UL UE Throughput < 400 Mbps<br/> bin15: 400 Mbps <= UL UE Throughput < 600 Mbps<br/> bin16: 600 Mbps <= UL UE Throughput < 800 Mbps<br/> bin17: 800 Mbps <= UL UE Throughput < 1 Gbps<br/> bin18: 1 Gbps <= UL UE Throughput < 2 Gbps<br/> bin19: 2 Gbps <= UL UE Throughput < 5 Gbps<br/> bin20: 5 Gbps <= UL UE Throughput</p> | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | <p>Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4</p> <p><u>O-RAN addition:</u><br/>The per UE throughput is calculated by the following formula. And the bin defined in description should be used.</p> <p>If <math>\Sigma \text{ThpTimeUL} > 0</math>, <math>\frac{\Sigma \text{ThpVolUL}}{\Sigma \text{ThpTimeUL}} \times 1000 [\text{kbits/s}]</math><br/>If <math>\Sigma \text{ThpTimeUL} = 0</math>, <math>0 [\text{kbit/s}]</math></p> <p>S-NSSAI subcounter is maintained, the number of measurements is counted per the number of supported S-NSSAI. If related slice feature is not supported, only the S-NSSAI #0 is used.<br/>PmCountGroup subcounter of subcounter is maintained, the number of measurements is counted per the number of supported PmCountGroup.</p> | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | +| Measurement Type | <p>Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4</p> <p><u>O-RAN addition:</u><br/>OR.DRB.UEThpULLogDist.Bin.<i>SNSSAI.PmGroup</i>, where <i>SNSSAI</i> is S-NSSAI.<br/><i>PmGroup</i> is PmCountGroup number:<br/>0: #0<br/>1: #1<br/>...<br/>19: #19</p> | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.4 | + +1 + +2 + +## A.11.39 Non-linear Scale Distribution of DL UE throughput in gNB + +3 + +### A.11.39.1 Performance Counter Table + +| | | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.DRB.UEThpDLLogDist.Bin | +| Description | <p>Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2</p> <p><u>O-RAN addition:</u><br/>The split into subcounters per S-NSSAI is recommended when the Slicing feature is supported. The split into subcounter of subcounter per PmCountGroup.<br/>The reference measurement time T for calculating the throughput of each UE is 1000ms.<br/>The bins corresponding to the DL throughput experienced by the UE is defined as follows.<br/>bin1: 0 kbps <= DL UE Throughput < 500 Kbps<br/>bin2: 500 Kbps <= DL UE Throughput < 1 Mbps<br/>bin3: 1 Mbps <= DL UE Throughput < 5 Mbps<br/>bin4: 5 Mbps <= DL UE Throughput < 10 Mbps<br/>bin5: 10 Mbps <= DL UE Throughput < 20 Mbps<br/>bin6: 20 Mbps <= DL UE Throughput < 40 Mbps<br/>bin7: 40 Mbps <= DL UE Throughput < 60 Mbps<br/>bin8: 60 Mbps <= DL UE Throughput < 80 Mbps<br/>bin9: 80 Mbps <= DL UE Throughput < 100 Mbps<br/>bin10: 100 Mbps <= DL UE Throughput < 120 Mbps<br/>bin11: 120 Mbps <= DL UE Throughput < 160 Mbps<br/>bin12: 160 Mbps <= DL UE Throughput < 200 Mbps<br/>bin13: 200 Mbps <= DL UE Throughput < 400 Mbps</p> | + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | bin14: 400 Mbps <= DL UE Throughput < 800 Mbps<br>bin15: 800 Mbps <= DL UE Throughput < 1.6 Gbps<br>bin16: 1.6 Gbps <= DL UE Throughput < 2 Gbps<br>bin17: 2 Gbps <= DL UE Throughput < 4 Gbps<br>bin18: 4 Gbps <= DL UE Throughput < 8 Gbps<br>bin19: 8 Gbps <= DL UE Throughput < 16 Gbps<br>bin20: 16 Gbps <= DL UE Throughput | +| Collection Method | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | +| Condition | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2<br><br>O-RAN addition:<br>The per UE throughput is calculated by the following formula. And the bin defined in description should be used.<br><br>If $\Sigma\text{ThpTimeDl} > 0$ , $\frac{\Sigma\text{ThpVolDl}}{\Sigma\text{ThpTimeDl}} \times 1000 [\text{kbits/s}]$<br>If $\Sigma\text{ThpTimeDl} = 0$ , 0 [kbit/s]<br><br>S-NSSAI subcounter is maintained, the number of measurements is counted per the number of supported S-NSSAI. If related slice feature is not supported, only the S-NSSAI #0 is used.<br>PmCountGroup subcounter of subcounter is maintained, the number of measurements is counted per the number of supported PmCountGroup. | +| Measurement Result | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | +| Measurement Type | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2<br><br>O-RAN addition:<br>OR.DRB.UEThpDlLogDist.Bin. <i>SNSSAI.PmGroup</i> , where <i>SNSSAI</i> is S-NSSAI.<br><i>PmGroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | +| Switching Technology | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | +| Generation | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | +| Purpose | Refer to 3GPP TS 28.552 [14] clause 5.1.1.3.2 | + +## A.12 NR Cell Utilization performance counters (Type B) + +### A.12.1 PUSCH slots + +#### A.12.1.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUB.PuschSlot | +| Description | This counter provides the number of the slots when PUSCH was received.<br>This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PUSCH is received. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUB.PuschSlot | +| Measurement Object Class | NRCellDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.2 PDSCH slots + +### A.12.2.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUB.PdschSlot | +| Description | This counter provides the number of the slots when PDSCH was transmitted.<br>This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDSCH is transmitted. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUB.PdschSlot | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.3 PDCCH slots + +### A.12.3.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUB.PdcchSlot | +| Description | This counter provides the number of the slots when PDCCH was transmitted.<br>This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by 1 whenever PDCCH is transmitted. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUB.PdcchSlot | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.4 CCE utilization rate + +### A.12.4.1 Performance Counter Table + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUB.CceUtiliationRate | +| Description | This counter measures the following $x$ in the report period and provides $\text{round}(x, 2) \cdot 10^2$ . $x$ is the usage rate of CCE.<br>This is recommended to support for O-DU. | +| Collection Method | SI (Status Inspection) | +| Condition | Measurement subcounter is $\text{round}(x/y, 2) \cdot 10^2$ .<br>$x$ is incremented by the number of CCEs which are used to transmit DCI whenever PDCCH is transmitted.<br>$y$ is incremented by the number of CCEs which can be used whenever PDCCH is transmitted. | +| Measurement Result | Percentage/ $10^2$ (U16) | +| Measurement Type | OR.CellUB.CceUtiliationRate | + +| | | +|--------------------------|--------------------------------------------------| +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.5 UEs buffering UL/DL data + +### A.12.5.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUB.UeBufferingUIDIData | +| Description | This counter provides the accumulated number of the UEs buffering UL/DL data. This counter obtains the number of the UEs every 100 ms. This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UEs which have UL and/or DL data which is group of subcounter. <i>Pmgroup</i> . The number is acquired as an instantaneous value at every 100ms. Note: multiple 5QIs can be set per UE, each 5QI is counted per QoS flow. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUB.UeBufferingUIDIData. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.6 UEs buffering UL data + +### A.12.6.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUB.UeBufferingUIData | +| Description | This counter provides the accumulated number of the UEs buffering UL data. This counter obtains the number of the UEs every 100 ms. This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UEs which have UL data which is group of subcounter. <i>Pmgroup</i> . The number is acquired as an instantaneous value at every 100ms. Note: multiple 5QIs can be set per UE, each 5QI is counted per QoS flow. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUB.UeBufferingUIData. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.7 UEs buffering DL data + +### A.12.7.1 Performance Counter Table + +| | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUB.UeBufferingDLData. <i>Pmgroup</i> | +| Description | This counter provides the accumulated number of the UEs buffering DL data. This counter obtains the number of the UEs every 100 ms. This is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of the UEs which have DL data which is group of subcounter. <i>Pmgroup</i> . The number is acquired as an instantaneous value at every 100ms. Note: multiple 5QIs can be set per UE, each 5QI is counted per QoS flow. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUB.UeBufferingDLData. <i>Pmgroup</i> where <i>Pmgroup</i> is PmCountGroup number:<br>0: #0<br>1: #1<br>...<br>19: #19 | +| Measurement Object Class | NRCeIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.8 DRX inactive UEs + +### A.12.8.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUB.DrxInactUe | +| Description | This counter provides the accumulated number of the UEs configured as DRX inactive. This counter obtains the number of the UEs every 100 ms. This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | Measurement subcounter is incremented by the number of UEs of which <i>drx-InactivityTimer</i> is assumed to be running. The number is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUB.DrxInactUe | +| Measurement Object Class | NRCeIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.9 DRX active UEs + +### A.12.9.1 Performance Counter Table + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUB.DrxActUe | +| Description | This counter provides the accumulated number of the UEs configured as DRX active. This counter obtains the number of the UEs every 100 ms. This is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | Measurement subcounter is incremented by the number of UEs which is configured <i>drx-config</i> and of which <i>drx-InactivityTimer</i> is assumed not to be running.<br>The number is acquired as an instantaneous value at every 100ms. | +| Measurement Result | Integer number (U32) | +| Measurement Type | OR.CellUB.DrxActUe | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.12.10 PDSCH slot for paging + +### A.12.10.1 Performance Counter Table + +| | | +|--------------------------|-------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.CellUB.PdschSlotForPaging | +| Description | This counter provides the number of PDSCH slot in which paging message is actually transmitted. | +| Collection Method | CC (Cumulative Counter) | +| Condition | This counter is incremented by 1 even when the same paging message is transmitted for different beam. | +| Measurement Result | Integer number(U32) | +| Measurement Type | OR.CellUB.PdschSlotForPaging | +| Measurement Object Class | NRCelIDU | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13 O-RU Performance counters measured at O-DU + +### A.13.1 Uplink data and control frames received in total + +#### A.13.1.1 Performance Counter Table + +| | | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RX.Total | +| Description | The total number of control/user plane messages received.<br>It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The total number of control/user plane eCPRI or 1914.3 messages received. This counter is the sum of all valid and errored messages received. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RX.Total | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.2 Uplink data frames received on Time + +### A.13.2.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RXData.OnTime | +| Description | The number of inbound user plane messages that arrived within the specified time window.<br>It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The number of inbound <u>user</u> plane (ecpri type 0) messages that arrived within the specified time window. Some “on time” messages may have sequence number errors or corruption errors but as long as they arrived within specified window time, this counter should include them. If the received message has been transport-fragmented, the full message shall be reassembled before checking its arrival window. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RXData.OnTime | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator’s Traffic Engineering Community | + +## A.13.3 Uplink data frames received too early + +### A.13.3.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RXData.TooEarly | +| Description | The number of inbound <u>user</u> plane messages which were detected to have arrived before the start of their designated receive window time.<br>It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The number of inbound <u>user</u> plane messages which were detected to have arrived before the start of their designated receive window time. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RXData.TooEarly | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator’s Traffic Engineering Community | + +## A.13.4 Uplink data frames received too late + +### A.13.4.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RXData.TooLate | +| Description | The number of inbound <u>user</u> plane messages which were detected to have arrived after the end of their designated receive window time.<br>It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The number of inbound <u>user</u> plane messages which were detected to have arrived after the end of their designated receive window time. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RXData.TooLate | +| Measurement Object Class | aggregation (O-RU) | + +| | | +|----------------------|--------------------------------------------------| +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.5 Uplink control frames received on Time + +### A.13.5.1 Performance Counter Table + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RXControl.OnTime | +| Description | The number of inbound <u>control</u> plane messages which were detected to have arrived before the start of their designated receive window time. It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The number of valid inbound <u>control</u> plane (ecpri type 2) messages that arrived within the specified time window. Some "on time" messages may have sequence number errors or corruption errors but as long as they arrived within specified window time, this counter should count them. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RXControl.OnTime | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.6 Uplink control frames received too early + +### A.13.6.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RXControl.TooEarly | +| Description | The number of inbound <u>control</u> plane messages which were detected to have arrived after the end of their designated receive window time. It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The number of inbound <u>control</u> plane messages which were detected to have arrived before the start of their designated receive window time. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RXControl.TooEarly | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.7 Uplink control frames received too late + +### A.13.7.1 Performance Counter Table + +| | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RXControl.TooLate | +| Description | The number of inbound <u>user</u> plane messages which were detected to have arrived after the end of their designated receive window time. It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | + +| | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------| +| Condition | The number of inbound <u>control</u> plane messages which were detected to have arrived after the end of their designated receive window time. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RXControl.TooLate | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.8 Uplink data frames with detecting sequence identifier error + +### A.13.8.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RXData.SeqidErr | +| Description | The number of inbound <u>on time</u> <u>user</u> plane messages in which a sequence identifier number error is detected.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The number of inbound on time user plane messages in which a sequence identifier number error is detected.<br>This error occurs when the ecpriSeqId field does not increment. Both the Sequence ID, and Subsequence ID fields must be checked if transport fragmentation is supported otherwise only the Sequence ID field may be checked.<br>In addition to identifying a sending equipment sequencing error, this counter can increment when packets are dropped prior to reception by the RU, or when packets reordered by the network exceed the receiving device's capabilities. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RXData.SeqidErr | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.9 Uplink control frames with detecting sequence identifier error + +### A.13.9.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RXControl.SeqidErr | +| Description | The number of inbound <u>on time</u> <u>control</u> messages in which a sequence identifier number error is detected.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The number of inbound <u>on time</u> <u>control</u> messages in which a sequence identifier number error is detected.<br>This counter increments under the same conditions as the rx_seqid_num_err except for control plane messages. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RXControl.SeqidErr | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.10 Uplink frames with corrupt contents + +### A.13.10.1 Performance Counter Table + +| | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RX.Corrupt | +| Description | The number of inbound <u>on time</u> messages with a correct ecpriSeqId (no sequence number error) which are dropped by the terminating entity due to the message containing one or more eCPRI/1914.3 or ORAN protocol errors.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The number of inbound <u>on time</u> messages with a correct ecpriSeqId (no sequence number error) which are dropped by the terminating entity due to the message containing one or more eCPRI/1914.3 or ORAN protocol errors.<br>Protocol errors are defined as when eCPRI/1914.3/ORAN defined fields contain invalid values or indicate unsupported capabilities. Some examples of this are:<br>1. Pcid or section Id number which has not been configured.<br>2. Unexpected use of C bit,<br>3. Unconfigured or Unsupported udCompHdr setting.<br>4. Unsupported section extension.<br>5. Wrong ecpriVersion and/or payloadVersion information<br>6. ecpriMessage field does not contain 0, 2, or 5. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RX.Corrupt | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.11 Uplink frames dropped and discarded. + +### A.13.11.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.RX.ErrDrop | +| Description | The total number of inbound messages which are discarded by the receiving O-RAN entity for any reason.<br>It is optional counter for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The total number of inbound messages which are discarded by the receiving O-RAN entity for any reason. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.RX.ErrDrop | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.12 Downlink control and data frames transmitted + +### A.13.12.1 Performance Counter Table + +| | | +|------------------|------------------------------------------------------------------| +| Measurement Name | OR.ORU.TX.Total | +| Description | The number of valid outbound <u>control/user</u> plane messages. | + +| | | +|--------------------------|---------------------------------------------------------------------------| +| | It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The number of valid outbound <u>control</u> / <u>user</u> plane messages. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.TX.Total | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.13.13 Downlink control frames transmitted to O-RU in total at O-DU + +### A.13.13.1 Performance Counter Table + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Measurement Name | OR.ORU.TXControl.Total | +| Description | The number of valid outbound <u>control</u> plane messages. This counter is required only if RU supports LAA/LBT capabilities.<br>It is recommended to support for O-DU. | +| Collection Method | CC (Cumulative Counter) | +| Condition | The number of valid outbound <u>control</u> plane messages. This counter is required only if RU supports LAA/LBT capabilities. | +| Measurement Result | Integer number (U64) | +| Measurement Type | OR.ORU.TXControl.Total | +| Measurement Object Class | aggregation (O-RU) | +| Switching Technology | Packet Switched | +| Generation | 5GS | +| Purpose | Network Operator's Traffic Engineering Community | + +## A.14 O-RU Performance counters measured at O-RU + +Please see [2]. + +## Annex B (informative): Optional Multi-Vendor Functionality + +### B.1: Optional Namespace Exposed Using O-RAN WG5 Models + +Some of the O-RAN WG5 defined YANG models are optional for the O-DU to support. In this version of the management plane specification, the following O-RAN WG5 defined YANG models are optional to support. If an O-DU/NETCONF server does not return the namespace associated with an optional O-RAN WG5 defined YANG model, the NETCONF client can infer that the O-DU does not support the optional capability associated with the model. + +| No | Optional Functionality | Reference | Namespace | +|----|------------------------|-----------|-----------| +| | | | | + +**Table 3: Optional O-RAN WG5 Namespace** + +## B.2: Optional Namespace Exposed Using O-RAN WG4 Models + +Some of the O-RAN WG4 defined YANG models are optional to support. If a device does not return the namespace associated with an optional O-RAN WG4 defined YANG model, the NETCONF client can infer that the device does not support the optional capability associated with the model. + +| No | Optional Functionality | Reference | Namespace | +|----|------------------------------------------------------------|-----------------------------------------------------------|---------------------------------------------------------| +| 1 | Antenna Line Device | O-RAN WG4 Management Plane Specification [2], Clause 14.4 | "urn:o-ran:ald-port:x.y"<br>"urn:o-ran:ald: x.y " | +| 2 | External IO Port | O-RAN WG4 Management Plane Specification [2], Clause 14.5 | "urn:o-ran:external-io:x.y " | +| 3 | eCPRI delay measurement | O-RAN WG4 Management Plane Specification [2], Clause 7.7 | "urn:o-ran:message5:x.y " | +| 4 | UDP Echo functionality for IP based transport verification | O-RAN WG4 Management Plane Specification [2], Clause 7.6 | "urn:o-ran:udpecho:x.y " | +| 5 | Beamforming | O-RAN WG4 Management Plane Specification [2], Clause 15.4 | "urn:o-ran:beamforming:x.y " | +| 6 | FAN | - | "urn:o-ran:fan:x.y" | +| 7 | LAA | O-RAN WG4 Management Plane Specification [2], Clause 16 | "urn:o-ran:laa:x.y "<br>"urn:o-ran:laa-operations:x.y " | + +**Table 4: Optional O-RAN WG4 Namespace** + +## B.3: Optional YANG Features Exposed Using O-RAN WG5 Models + +Some of the O-RAN WG5 defined YANG models define optional feature support. The optional multi-vendor features defined in the O-RAN WG5 defined YANG models are shown below. + +| No | Optional Feature | Namespace | Feature name | +|----|------------------|-----------|--------------| +| | | | | + +**Table 5: Optional O-RAN WG5 defined feature support** + +## B.4: Optional YANG Features Exposed Using O-RAN WG4 Models + +Some of the O-RAN WG4 defined YANG models define optional feature support. The optional multi-vendor features defined in the O-RAN WG4 defined YANG models are shown below. + +| No | Optional Feature | Namespace | Feature name | +|----|-----------------------------|---------------------------|---------------------| +| 1 | Adaptive O-RU delay profile | "urn:o-ran:delay:x.y " | ADAPTIVE-RU-PROFILE | +| 2 | O-RU Energy saving | "urn:o-ran:hardware:x.y " | ENERGYSAVING | + +| | | | | +|----|---------------------------------------|-----------------------------------------|-----------------------------------| +| 3 | Alias MAC address based C/U transport | "urn:o-ran:interfaces:x.y " | ALIASMACHASED-CU-PLANE | +| 4 | UDP/IP based C/U Transport | "urn:o-ran:interfaces:x.y " | UDPIP-BASED-CU-PLANE | +| 5 | Dynamic Beamforming Configuration | "urn:o-ran:beamforming:x.y " | MODIFY-BF-CONFIG | +| 6 | GNSS Support | "urn:o-ran:sync:x.y " | GNSS | +| 7 | ALD overcurrent reporting | "urn:o-ran:ald-port:x.y " | OVERCURRENT-SUPPORTED | +| 8 | TRANSPORT in rx-window-measurement | "urn:o-ran:performance-management:x.y " | GRANULARITY-TRANSPORT-MEASUREMENT | +| 9 | EAXC_ID in rx-window-measurement | "urn:o-ran:performance-management:x.y " | GRANULARITY-EAXC-ID-MEASUREMENT | +| 10 | LAA Support | "urn:o-ran: module-cap " | LAA | +| 11 | Transport Fragmentation | "urn:o-ran:module-cap:x.y " | TRANSPORT-FRAGMENTATION | +| 12 | GNSS Anti Jamming | "urn:o-ran:sync:x.y " | ANTI-JAM | +| 13 | Tilting pre-defined beams | "urn:o-ran:beamforming:x.y" | BEAM-TILT | + +**Table 6: Optional O-RAN WG4 defined feature support** + +## B.5: Optional YANG Features Exposed Using Common Models + +Some of the O-RAN defined YANG models augment existing YANG models which have optional features defined. The optional features defined in these “common” models are shown in the table below. + +| No | Optional Feature | Namespace | Feature name | +|----|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------|------------------------------| +| 1 | RFC 6933 [i.7]: Entity MIB | "urn:ietf:params:xml:ns:yang:ietf-hardware" | entity-mib | +| 2 | RFC 4268 [i.8]: Entity State MIB | "urn:ietf:params:xml:ns:yang:ietf-hardware" | hardware-state | +| 3 | RFC 3433 [i.9]: Entity Sensor Management Information Base | "urn:ietf:params:xml:ns:yang:ietf-hardware" | hardware-sensor | +| 4 | O-RU allows user-controlled interfaces to be named arbitrarily | "urn:ietf:params:xml:ns:yang:ietf-interfaces" | arbitrary-names | +| 5 | O-RU supports pre-provisioning of interface configuration, i.e., it is possible to configure an interface whose physical interface hardware is not present on the device | "urn:ietf:params:xml:ns:yang:ietf-interfaces" | pre-provisioning | +| 6 | RFC 2863 [i.10]: The Interfaces Group MIB | "urn:ietf:params:xml:ns:yang:ietf-interfaces" | if-mib | +| 7 | O-RU supports configuring non-contiguous subnet masks | "urn:ietf:params:xml:ns:yang:ietf-ip" | ipv4-non-contiguous-netmasks | +| 8 | O-RU supports privacy extensions for stateless address autoconfiguration in IPv6 | "urn:ietf:params:xml:ns:yang:ietf-ip" | ipv6-privacy-autoconf | + +**Table 7: Optional feature support in common models** + +## B.6: Optional Capabilities Exposed Using O-RAN WG5 Models + +In addition to optional namespaces and optional features within supported namespaces, certain O-RAN WG5 defined YANG models are used to be able to expose support for certain optional capabilities by the O-DU. + +| No | Optional Feature | Namespace | Leaf | +|----|------------------|-----------|------| +| | | | | + +**Table 8: Optional capabilities in O-RAN WG5 defined YANG models** + +## B.7: Optional Capabilities Exposed Using O-RAN WG4 Models + +In addition to optional namespaces and optional features within supported namespaces, certain O-RAN WG4 defined YANG models are used to be able to expose support for certain optional capabilities by the O-RU. + +| No | Optional Feature | Namespace | Leaf | +|----|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------|----------------------------------------------------------------------------------------------------------------------------------| +| 1 | Type of synchronization source supported by O-RU | "urn:o-ran:sync:x.y " | / sync:/sync-status/supported-reference-types | +| 2 | O-RU supports extended Category A operation – more than 8 spatial streams | "urn:o-ran:module-cap:x.y " | /module-capability/ru-capabilities/ru-supported-category and<br><br>/module-capability/ru-capabilities/number-of-spatial-streams | +| 3 | O-RU supports Category B operation – precoding in the O-RU | "urn:o-ran:module-cap:x.y " | /module-capability/ru-capabilities/ru-supported-category | +| 4 | O-RU supports the capability to apply the modified beamforming configuration by using rpc activate-beamforming-config without deletion of tx-array-carriers and rx-array-carriers | "urn:o-ran:beamforming:x.y " | /beamforming-configuration/operational-properties/update-bf-non-delete | +| 5 | O-RU supports the capability to store the modified beamforming configuration file in the reset persistent memory | "urn:o-ran:beamforming:x.y " | /beamforming-configuration/operational-properties/persistent-bf-files | +| 6 | Optional VLAN optimized searching | "urn:o-ran:mplane-interfaces:x.y " | /mplane-info/searchable-mplane-access-vlans-info | +| 7 | Configurable CoS marking for C, U and M-Plane | "urn:o-ran:interfaces:x.y " | augmented /if:interfaces/if:interface: with u-plane-marking c-plane-marking and m-plane-marking | +| 8 | Configurable DSCP marking for C, U and M-Plane | "urn:o-ran:interfaces:x.y " | augmented /if:interfaces/if:interface: with u-plane-marking c-plane-marking and m-plane-marking | +| 9 | Ethernet Frame MTU | "urn:o-ran:interfaces:x.y" | augmented /if:interfaces/if:interface: with l2-mtu | +| 10 | VLAN Tagging | "urn:o-ran:interfaces:x.y" | augmented /if:interfaces/if:interface: with vlan-tagging | +| 11 | IEEE 1914.3 header support | "urn:o-ran:operations:x.y " | /operational-info/o-ran-split/optional-header-support | +| 12 | eCPRI Concatenation support | "urn:o-ran:operations:x.y " | /operational-info/o-ran-split/ecpri-concatenation-support | +| 13 | O-RU local management of the LAA contention window | "urn:o-ran:module-cap:x.y " | /module-capability/band-capabilities/sub-band-info/self-configure | +| 14 | O-RU supports LAA ending in Downlink Pilot Time Slot (DwPTS) | "urn:o-ran:laa:x.y" | /laa-config/ laa-ending-dwpts-supported | +| 15 | O-RU supports configurable timer for C/U plane monitoring | "urn:o-ran: supervision:x.y" | /supervision/cu-plane-monitoring | + +**Table 9: Optional capabilities in O-RAN WG4 defined YANG models** + +## B.8: Optional Capabilities Exposed Using Common Models + +When O-RAN defines augmentation of existing YANG models, these models may expose support for certain optional capabilities by the O-RU. + +| No | Optional Feature | Namespace | Leaf | +|----|------------------------|---------------------------------------|--------------------------------------------------| +| 1 | IPv6 Supported by O-RU | "urn:ietf:params:xml:ns:yang:ietf-ip" | augmented /if:interfaces/if:interface: with ipv6 | + +**Table 10: Optional capabilities in common YANG models** + +## Annex C (informative): YANG Module Graphical Representation + +The different released version of the set of YANG modules for the O-DU can be downloaded from O-RAN's website <http://www.o-ran.org/resources/>. The YANG models are available in a zip file, whose name is used to represent the version of the YANG model and follows the numerical format defined in subclause 1.1 with the periods replaced with "-", i.e., YANG models for release 1.0.0 of the O1 interface specification are available in the file 1-0-0.zip. This zip file includes all published revisions of the YANG models supporting a particular release of the O1 interface specification. + +This Annex provides a set of "tree-views" of the modules to provide a simplified graphical representation of the data models. These trees have been automatically generated using the pyang YANG validator tool. If there are any inconsistencies between the tree representation in this Annex and the yang models, the yang models shall take precedence. + +For WG4 YANG modules please refer to O-RAN WG4 Management Plane Specification [2] Annex D. + +### C.1 Additional configuration folder + +Currently no module can be represented in tree view as all of modules in this folder are augmentations of 3GPP modules. + +### C.2 Common Models folder + +#### C.2.1 o-ran-dhcp.yang Module + +``` + +module: o-ran-dhcp + +--ro dhcp + +--ro interfaces* [interface] + | +--ro interface if:interface-ref + | +--ro dhcpv4 + | | +--ro client-id? string + | | +--ro dhcp-server-identifier? inet:ip-address + | | +--ro domain-name? string + | | +--ro domain-name-servers* inet:ip-address + | | +--ro interface-mtu? uint32 + | | +--ro default-gateways* inet:ip-address + | | +--ro netconf-clients* [client] + | | | +--ro client netconf-client-id + | | | +--ro optional-port? inet:port-number + | | | +--ro ca-ra-servers* [servers] + | | | | +--ro servers ca-ra-server-id + | | | | +--ro optional-port? inet:port-number + | | | | +--ro ca-ra-path? string + | | | | +--ro subject-name? string + | | | | +--ro protocol? enumeration + | | | +--ro segw* [gateways] + | | | | +--ro gateways segw-id + | | +--ro dhcpv6 + | | +--ro dhcp-client-identifier + +``` + +``` + +1 +--ro dhcp-server-identifier +2 +--ro domain-name? string +3 +--ro domain-name-servers* inet:ip-address +4 +--ro netconf-clients* [client] +5 | +--ro client netconf-client-id +6 | +--ro optional-port? inet:port-number +7 +--ro ca-ra-servers* [servers] +8 | +--ro servers ca-ra-server-id +9 | +--ro optional-port? inet:port-number +10 | +--ro ca-ra-path? string +11 | +--ro subject-name? string +12 | +--ro protocol? enumeration +13 +--ro segw* [gateways] +14 | +--ro gateways segw-id +15 +--ro m-plane-dhcp +16 +--ro private-enterprise-number? uint16 +17 +--ro vendor-class-data? string +18 + +``` + +## C.2.2 o-ran-synchronization.yang Module + +``` + +20 module: o-ran-synchronization +21 +--rw sync +22 +--rw sync-functions +23 +--ro sync-state enumeration +24 +--ro sync-capability +25 | +--ro partial-timing-supported? boolean +26 | +--ro supported-reference-types* [sync-source] +27 | | +--ro sync-source enumeration +28 +--rw sync-config +29 | +--rw sync-priority-config* [sync-source] +30 | | +--rw sync-source enumeration +31 | | +--rw sync-enabled? boolean +32 +--rw ptp-config +33 | +--rw domain-number? uint8 +34 | +--rw accepted-clock-classes* [clock-classes] +35 | | +--rw clock-classes uint8 +36 | +--rw delay-asymmetry? int16 +37 | +--rw ptp-profile? enumeration +38 | +--rw g-8275-1-config +39 | | +--rw multicast-mac-address? enumeration +40 +--rw g-8275-2-config +41 | +--rw local-ip-port? -> /if:interfaces/interface/name +42 | +--rw master-ip-configuration* [local-priority] +43 | | +--rw local-priority uint8 +44 | | +--rw ip-address? string +45 | +--rw log-inter-sync-interval? int8 +46 | +--rw log-inter-announce-interval? int8 +47 +--rw ptp-status +48 | +--rw reporting-period? uint8 +49 | +--ro clock-class? uint8 +50 | +--ro clock-identity? string +51 +--ro sources* [source-clock-identity] +52 | +--ro sync-source-status? enumeration +53 | +--ro clock-class? uint8 +54 | +--ro clock-accuracy? uint8 +55 | +--ro offset-scaled-log-variance? uint16 +56 | +--ro priority1? uint8 +57 | +--ro priority2? uint8 +58 | +--ro grandmaster-clock-identity? string +59 | +--ro source-clock-identity string +60 | +--ro source-port-number? uint16 +61 | +--ro steps-removed? uint16 +62 | +--ro local-port-number? -> /if:interfaces/interface/o-ran-int:port-reference/port- +63 number +64 +--ro ptp-timescale? boolean +65 +--ro time-source? uint8 +66 +--ro time-traceable? boolean +67 +--ro frequency-traceable? boolean +68 +--ro current-utc-offset? int16 +69 +--ro current-utc-offset-valid? boolean +70 +--ro leap61? boolean +71 +--ro leap59? boolean +72 +--ro two-step-flag? boolean + +``` + +``` + +1 | +--rw sync-config +2 | | +--rw acceptance-list-of-ssm* enumeration +3 | | +--rw ssm-timeout? uint16 +4 | +--rw sync-status +5 | | +--rw reporting-period? uint8 +6 | | +--ro sources* [source-clock-identity] +7 | | | +--ro source-clock-identity string +8 | | | +--ro sync-source-status? enumeration +9 | | | +--ro quality-level? uint8 +10 | +--rw gnss-config {GNSS}? +11 | | +--rw enable? boolean +12 | | +--rw satellite-constellation-list* enumeration +13 | | +--rw polarity? enumeration +14 | | +--rw cable-delay? uint16 +15 | | +--rw anti-jam-enable? boolean {ANTI-JAM}? +16 | +--rw gnss-status {GNSS}? +17 | | +--rw reporting-period? uint8 +18 | | +--ro name? string +19 | | +--rw sync-source-status? enumeration +20 | | +--ro gnss-sync-status? enumeration +21 | | +--ro gnss-data +22 | | | +--ro satellites-tracked? uint8 +23 | | | +--ro location +24 | | | | +--ro altitude? int64 +25 | | | | +--ro latitude? geographic-coordinate-degree +26 | | | | +--ro longitude? geographic-coordinate-degree +27 | +--rw sync-master-functions +28 | | +--ro sync-master-capabilities +29 | | | +--ro ptp-sync-master-capabilities +30 | | | | +--ro ptp-sync-master-supported? boolean +31 | | | +--ro sync-sync-master-capabilities +32 | | | | +--ro sync-sync-master-supported? boolean +33 | | +--rw sync-master-configuration +34 | | | +--rw ptp-master-configuration +35 | | | | +--rw ptp-master-enabled-local-port-numbers* -> /if:interfaces/interface/o-ran-int:port- +36 | | | | reference/port-number +37 | | | | +--rw domain-number? uint8 +38 | | | | +--rw multicast-mac-address? enumeration +39 | | | | +--ro clock-identity? string +40 | | | | +--rw priority2? uint8 +41 | | | +--rw ptp-status +42 | | | | +--rw reporting-period? uint8 +43 | | | | +--ro clock-class? uint8 +44 | | | | +--ro clock-identity? string +45 | | | | +--ro sources* [source-clock-identity] +46 | | | | | +--ro sync-source-status? enumeration +47 | | | | | +--ro clock-class? uint8 +48 | | | | | +--ro clock-accuracy? uint8 +49 | | | | | +--ro offset-scaled-log-variance? uint16 +50 | | | | | +--ro priority1? uint8 +51 | | | | | +--ro priority2? uint8 +52 | | | | | +--ro grandmaster-clock-identity? string +53 | | | | | +--ro source-clock-identity string +54 | | | | | +--ro source-port-number? uint16 +55 | | | | | +--ro steps-removed? uint16 +56 | | | | | +--ro local-port-number? -> /if:interfaces/interface/o-ran-int:port- +57 | | | | | reference/port-number +58 | | | | | +--ro ptp-timescale? boolean +59 | | | | | +--ro time-source? uint8 +60 | | | | | +--ro time-traceable? boolean +61 | | | | | +--ro frequency-traceable? boolean +62 | | | | | +--ro current-utc-offset? int16 +63 | | | | | +--ro current-utc-offset-valid? boolean +64 | | | | | +--ro leap61? boolean +65 | | | | | +--ro leap59? boolean +66 | | | | | +--ro two-step-flag? boolean +67 | | | +--rw sync-master-configuration +68 | | | | +--rw sync-master-enabled-local-port-numbers* -> /if:interfaces/interface/o-ran-int:port- +69 | | | | reference/port-number + +``` + +## C.2.3 o-ran-wg5-delay-management Module + +``` +module: o-ran-wg5-delay-management +``` + +``` + ++--rw wg5-delay-management + +--ro window-determine-capability enumeration + +--rw window-determine-method + | +--rw method enumeration + | +--rw configuration-status -> /wg5-delay-management/window-determine-capability + | +--rw pre-configured-transport-delay* [ru-instance-id] + | +--rw ru-instance-id ru-ref + | +--rw t12-min uint32 + | +--rw t12-max uint32 + | +--rw t34-min uint32 + | +--rw t34-max uint32 + +--rw o-du-window* [ru-instance-id bandwidth subcarrier-spacing] + | +--rw ru-instance-id ru-ref + | +--rw bandwidth bandwidth + | +--rw subcarrier-spacing uint32 + | +--rw ta4-min uint32 + | +--rw ta4-max uint32 + | +--rw t1a-min-cp-dl uint32 + | +--rw t1a-min-cp-ul uint32 + | +--rw t1a-min-up uint32 + | +--rw t1a-max-cp-dl uint32 + | +--rw t1a-max-cp-ul uint32 + | +--rw t1a-max-up uint32 + +--ro o-ru-window* [ru-instance-id bandwidth subcarrier-spacing] + | +--ro ru-instance-id ru-ref + | +--ro bandwidth bandwidth + | +--ro subcarrier-spacing uint32 + | +--ro t2a-min-up uint32 + | +--ro t2a-max-up uint32 + | +--ro t2a-min-cp-dl uint32 + | +--ro t2a-max-cp-dl uint32 + | +--ro tcp-adv-dl uint32 + | +--ro ta3-min uint32 + | +--ro ta3-max uint32 + | +--ro t2a-min-cp-ul uint32 + | +--ro t2a-max-cp-ul uint32 + +--ro measured-transport-delay* [ru-instance-id] + +--ro ru-instance-id ru-ref + +--ro t12-min uint32 + +--ro t12-max uint32 + +--ro t34-min uint32 + +--ro t34-max uint32 + +``` + +## C.3 DU Specific Models folder + +### C.3.1 o-ran-aggregation-base.yang Module + +``` + +module: o-ran-aggregation-base + +--rw aggregated-o-ru + +--ro recovered-ru-instance-ids* [ru-instance-id] + | +--ro ru-instance-id ru-ref + +--rw aggregation* [ru-instance] + +--rw ru-instance -> /aggregated-o-ru/recovered-ru-instance-ids/ru-instance-id + +--rw or-agg-ops:operations-model + +--rw or-agg-pm:performance-management-model + +--rw or-agg-swm:software-management-model + +``` + +### C.3.2 o-ran-o1-ctiOdu.yang Module + +``` + +module: o-ran-o1-ctiOdu + + augment /me3gpp:ManagedElement/gnbdu3gpp:GNBDUFunction: + +--rw CTIFunction* [id] {or-features:CTI}? + +--rw id string + +--rw attributes + | +--rw ctiActivateOnOdu boolean + +--rw CTIClient* [id] + +``` + +``` + +1 | +--rw id string +2 | +--rw attributes +3 | | +--rw ctiClientMacAddr? yang:mac-address +4 | | +--rw ctiClientInfo? string +5 | | +--rw ctiClientServerStatus* [ctiServerRef] +6 | | +--rw ctiServerRef -> +7 | /me3gpp:ManagedElement/gnbdu3gpp:GNBDUFunction/CTIFunction/CTIServer/attributes/ctiServerId +8 | | +--rw ctiClientServerActivate boolean +9 | | +--ro ctiClientServerConnStatus boolean +10 | | +--rw CTISessionGroup* [id] +11 | | | +--rw id string +12 | | | +--rw attributes +13 | | | | +--rw ctiServerRef -> +14 | | | /me3gpp:ManagedElement/gnbdu3gpp:GNBDUFunction/CTIFunction/CTIServer/attributes/ctiServerId +15 | | | | +--rw ctiConnProfileRef -> +16 | | | /me3gpp:ManagedElement/gnbdu3gpp:GNBDUFunction/CTIFunction/CTIConnProfile/attributes/ctiConnProfileId +17 | | | +--rw CTISession* [id] +18 | | | | +--rw id string +19 | | | | +--rw attributes +20 | | | | | +--rw ctiSessionId string +21 | | | | | +--rw oruId? string +22 | | | | | +--rw oruInterfaceId? string +23 | | | | | +--rw ctiNominalReportMsgInterval uint8 +24 | | | | | +--rw ctiReportMessagingUseOfType1Ext boolean +25 | | | | +--rw CTIFlowsInUse* [id] +26 | | | | | +--rw id string +27 | | | | | +--rw attributes +28 | | | | | | +--rw timeIntervalPerReport uint8 +29 | | | | | | +--rw maxT34Latency uint16 +30 | | | | | | +--rw minLoad? uint8 +31 | | | | | | +--rw extraLoadCplane? uint8 +32 | | | | | | +--rw ctiFlowRef -> +33 | | | /me3gpp:ManagedElement/gnbdu3gpp:GNBDUFunction/CTIFunction/CTIServer/CTIFlow/attributes/ctiFlowId +34 | | | +--rw CTIConfig* [id] +35 | | | | +--rw id string +36 | | | | +--rw attributes +37 | | | | | +--ro ctiReportRateCategory uint8 +38 | | | | | +--ro ctiMessageTimingPerformance uint8 +39 | | | | | +--ro supportedCtiVersions* or-ctic:ctiVersion +40 | | | | | +--ro minNotificationAdvanceTime? uint16 +41 | | | | | +--rw ctiKa uint8 +42 | | | | | +--rw ctiTo uint8 +43 | | | | | +--rw protocolSubtype? uint16 +44 | | | | | +--rw ctiListeningUdpPort inet:port-number +45 | | +--rw CTIServer* [id] +46 | | | +--rw id string +47 | | | +--rw attributes +48 | | | | +--rw ctiServerId string +49 | | | | +--rw ctiServerInfo? string +50 | | | | +--rw connectivityType enumeration +51 | | | | +--rw ctiServerMacAddr yang:mac-address +52 | | | | +--rw ctiServerHost inet:host +53 | | | | +--rw ctiEnable boolean +54 | | | | +--rw supportedCtiVersions* or-ctic:ctiVersion +55 | | | | +--rw ctiReportMessagingUseOfType2 boolean +56 | | | | +--rw ponServerInfoUseNotificationsFromThisServer? boolean +57 | | | | +--rw docsisServerInfo? string +58 | | +--rw CTIFlow* [id] +59 | | | +--rw id string +60 | | | +--rw attributes +61 | | | | +--rw ctiFlowId uint8 +62 | | | | +--rw filterType enumeration +63 | | | | +--rw layer2Filter* [idx] +64 | | | | | +--rw idx uint32 +65 | | | | | +--rw sourceMac? yang:mac-address +66 | | | | | +--rw destinationMac? yang:mac-address +67 | | | | | +--rw ethertype? ethertype +68 | | | | | +--rw pcp? or-types:pcp +69 | | | | | +--rw vlanId? or-types:vlan-id +70 | | | | +--rw layer3and4Filter* [idx] +71 | | | | | +--rw idx uint32 +72 | | | | | +--rw sourceAddress? inet:ip-address +73 | | | | | +--rw sourcePrefix? inet:ip-prefix +74 | | | | | +--rw destinationAddress? inet:ip-address +75 | | | | | +--rw destinationPrefix? inet:ip-prefix + +``` + +``` + +1 | +--rw dscp? inet:dscp +2 | +--rw sourcePortStart? inet:port-number +3 | +--rw sourcePortEnd? inet:port-number +4 | +--rw destinationPortStart? inet:port-number +5 | +--rw destinationPortEnd? inet:port-number +6 | +--rw ipv4Protocol? uint8 +7 | +--rw ipv6TrafficClass? uint8 +8 | +--rw ipv6Flow? inet:ipv6-flow-label +9 | +--rw ipv6NextHeader? uint8 +10 | +--rw CTIConnProfile* [id] +11 | | +--rw id string +12 | | +--rw attributes +13 | | | +--rw ctiConnProfileId string +14 | | | +--rw connectivityType enumeration +15 | | | +--rw vlanTagForL2? or-types:vlan-id +16 | | | +--rw vlanTagForL3and4? or-types:vlan-id +17 | | | +--rw ctiClientHost? inet:host +18 | +--rw CTIPattern* [id] +19 | | +--rw id string +20 | | +--rw attributes +21 | | | +--rw patternId uint32 +22 | | | +--rw patternDuration uint8 +23 | | | +--rw patternEvents uint8 +24 | | | +--rw patternEventMultiplier uint8 +25 | | | +--rw patternEventBytes uint16 +26 | | | +--rw patternNormalization boolean + +``` + +### C.3.2 o-ran-o-du-shared-o-ru.yang + +``` + +29 module: o-ran-o-du-shared-o-ru +30 +31 augment /me3gpp:ManagedElement/gnbdu3gpp:GNBDUFunction: +32 +--rw SharedORuConfiguration* [id] +33 | +--rw id string +34 | +--rw attributes +35 | | +--rw oDuRoleOfSharedORu? enumeration +36 | | +--rw sharedResourceOperatorId? string +37 | | +--rw oDuIdForSharedORu? string +38 | | +--rw secondaryODuInfoList* [oDuIdForSharedORu] +39 | | | +--rw oDuIdForSharedORu string +40 | | | +--rw sharedResourceOperatorId? string +41 | | | +--rw accessCotrolGroup? string +42 | | | +--rw supervisionPerODu? boolean +43 | | | +--rw callHomeClientInfo* [host portNumber] +44 | | | | +--rw host inet:host +45 | | | | +--rw portNumber inet:port-number +46 | | +--rw sharedORuList* string + +``` + +## C.4 Provisioning folder + +Currently no module can be represented in tree view as all of modules in this folder are augmentations of o-ran-aggregation-base module. + +## C.5 CTI folder + +Currently no module can be represented in tree view. + +## Annex D (informative): WG4 instance categories in Hierarchical Model + +In the spreadsheet attached to this specification you can find categories of WG4 YANG data model instances + +Note: Yellow parts in above spreadsheet means that those parameters are not categorized yet. + +All instances are categorized by the following Legend. + +| Category | Legend | definition | +|----------|----------|----------------------------------| +| rw | <b>M</b> | Mapping from SA5 parameter | +| | <b>I</b> | Creating by O-DU internal logic | +| | <b>A</b> | Configuring by Aggregation model | +| ro | <b>M</b> | Mapping to SA5 parameter | +| | <b>N</b> | No need to notify to SMO | +| | <b>A</b> | Get by Aggregation model | + +Table 11: Categories for YANG parameters + +## Annex E (informative): Parameters definition for 3GPP conformance testing + +| TS38.141-1<br>Section # | Test | Configuration | Measurements | Measurements<br>Reports | +|-------------------------|----------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------|-------------------------| +| 7.2 | Reference sensitivity level | <ol style="list-style-type: none"> <li>Test item</li> <li>Type of FRC</li> <li>Carrier frequency</li> <li>PRB offset</li> <li>Beam ID (if O-RU performs beamforming)</li> </ol> | <ol style="list-style-type: none"> <li>Number of receptions</li> <li>Number of CRC-OK</li> </ol> | Throughput | +| 7.3 | Dynamic Range | | | | +| 7.4.1 | Adjacent Channel Selectivity | | | | +| 7.4.2 | In-band blocking | | | | +| 7.5 | Out-of-band blocking | | | | +| 7.7 | Receiver intermodulation | | | | +| 7.8 | In-channel selectivity | | | | +| 8.2.1 | Performance requirements for PUSCH with transform precoding disabled | <ol style="list-style-type: none"> <li>Test item</li> <li>Type of FRC</li> <li>Carrier frequency</li> <li>PRB offset</li> <li>PUCCH mapping type (A or B)</li> <li>Beam ID (if O-RU performs beamforming)</li> </ol> | <ol style="list-style-type: none"> <li>Number of receptions</li> <li>Number of CRC-OK</li> </ol> | Throughput | +| 8.2.2 | Performance requirements for PUSCH with transform precoding enabled | Same as 8.2.1 | Same as 8.2.1 | Same as 8.2.1 | +| 8.2.3 | Performance requirements for UCI multiplexed on PUSCH | <ol style="list-style-type: none"> <li>Test item</li> <li>Type of FRC</li> <li>Carrier frequency</li> <li>PRB offset</li> <li>PUCCH mapping type (A or B)</li> <li>Number of UCI bits (7 bits or 40 bits)</li> </ol> | <ol style="list-style-type: none"> <li>Number of USI on PUSCH reception slots</li> <li>Number of HARQ NACK</li> </ol> | BLER | + +| | | | | | +|---------|--------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------| +| | | 7. Beam ID (if O-RU performs beamforming) | | | +| 8.2.4 | Performance requirements for PUSCH for high speed train | Same as 8.2.1 | Same as 8.2.1 | Same as 8.2.1 | +| 8.2.5 | Performance requirements for UL timing adjustment | Same as 8.2.1 | Same as 8.2.1 | Same as 8.2.1 | +| 8.2.6 | Performance requirements for PUSCH with 0.001% BLER | Same as 8.2.1 | Same as 8.2.3 | Same as 8.2.3 | +| 8.2.7 | Performance requirements for PUSCH repetition Type A | Same as 8.2.1 | Same as 8.2.3 | Same as 8.2.3 | +| 8.2.8 | Performance requirements for PUSCH Mapping Type B with non-slot transmission | Same as 8.2.1<br>Note: PUCCH mapping type is B | Same as 8.2.1 | Same as 8.2.1 | +| 8.2.9 | Performance requirements for PUSCH msgA for 2-step RA type | Same as 8.2.1 | Same as 8.2.3 | Same as 8.2.3 | +| 8.3.1 | Performance requirements for PUCCH format 0 | 1. Test item<br>2. Carrier frequency<br>3. PRB offset<br>4. PUCCH format (test case)<br>5. Beam ID (if O-RU performs beamforming) | 1. Number of PUCCH reception slots<br>2. Number of HARQ ACK | 1. Probability of ACK detection<br>2. Probability of ACK missed detection | +| 8.3.2.1 | Performance requirements for PUCCH format 1: NACK to ACK | Same as 8.3.1 | 1. Number of PUCCH reception slots<br>2. Number of HARQ ACK in idle period<br>3. Number of HARQ ACK in NACK bits | 1. Probability of ACK false detection<br>2. Probability of NACK to ACK detection | +| 8.3.2.2 | Performance requirements for PUCCH format 1: ACK missed detection | Same as 8.3.1 | 1. Number of PUCCH reception slots<br>2. Number of HARQ ACK in idle period<br>3. Number of HARQ ACK in ACK bits | 1. Probability of ACK false detection<br>2. Probability of ACK detection | +| 8.3.3.1 | Performance requirements for PUCCH format 2: ACK missed detection | Same as 8.3.1 | Same as 8.3.2.2 | Same as 8.3.2.2 | +| 8.3.3.2 | Performance requirements for PUCCH format 2: UCI BLER performance requirements | Same as 8.3.1 | 1. Number of PUCCH reception slots<br>2. Number of CRC NG (UCI decoding) | UCI block error | +| 8.3.4 | Performance requirements for PUCCH format 3 | 1. Test item<br>2. Carrier frequency<br>3. PRB offset<br>4. PUCCH format (test case)<br>5. Test 1 or Test 2<br>6. Beam ID (if O-RU performs beamforming) | Same as 8.3.3.2 | Same as 8.3.3.2 | + +| | | | | | +|-------|----------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------| +| 8.3.5 | Performance requirements for PUCCH format 4 | Same as 8.3.1 | Same as 8.3.3.2 | Same as 8.3.3.2 | +| 8.4.1 | PRACH false alarm probability and missed detection | <ol style="list-style-type: none"> <li>Test item</li> <li>Carrier frequency</li> <li>PRB offset</li> <li>PRACH format (test case)</li> <li>Beam ID (if O-RU performs beamforming)</li> </ol> | <ol style="list-style-type: none"> <li>Total probability of false PRACH detection (Pfa) <ol style="list-style-type: none"> <li>Number of PRACH reception slots</li> <li>Number of preamble detection slots</li> </ol> </li> <li>Probability of PRACH detection (Pd) <ol style="list-style-type: none"> <li>Number of PRACH reception slots</li> <li>Number of preamble detection slots</li> <li>Value of TA when detecting preamble in each slot</li> </ol> </li> </ol> <p>Note: TA is considered when calculating Pd</p> | <ol style="list-style-type: none"> <li>Pfa</li> <li>Pd</li> </ol> | + +Table 12: Parameters for O-RU uplink evaluation + +| TS38.141-1 Section # | Test | Configuration | Measurements | Measurements Reports | +|----------------------|--------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------|----------------------| +| 6.2 | Base station output power | <ol style="list-style-type: none"> <li>Test item</li> <li>Cell identifier</li> <li>Carrier frequency</li> <li>Type of test model</li> <li>Tx bandwidth [RB] and SCS</li> <li>Number of antenna ports</li> <li>Beam ID (if O-RU performs beamforming)</li> </ol> | None.<br>Measurement at O-DU is not required. | | +| 6.3.2 | RE power control dynamic range | | | | +| 6.3.3 | Total power dynamic range | | | | +| 6.4.1 | Transmitter OFF power | | | | +| 6.4.2 | Transmitter transient period | | | | +| 6.5.1 | Frequency error | | | | +| 6.5.2 | Modulation quality | | | | +| 6.5.3 | Time alignment error | | | | +| 6.6.2 | Occupied bandwidth | | | | +| 6.6.3 | Adjacent channel leakage power ratio | | | | +| 6.6.4 | Operating band unwanted emissions | | | | +| 6.6.5 | Transmitter spurious emissions | | | | +| 6.7 | Transmitter intermodulation | | | | + +Table 13: Parameters for O-RU downlink evaluation + +1 +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 +16 +17 +18 +19 +20 +21 +22 +23 +24 +25 +26 +27 +28 +29 +30 +31 +32 +33 +34 + +# Annex F (informative): Network Energy Saving + +## F.1 Introduction + +This section describes the requirements and scope of the energy saving techniques relevant to O1 interface [i.11] and its associated information. The following techniques are employed to attain the network energy saving. + +## F.2 Cell and carrier deactivation / activation + +### F.2.1 Flow description + +1. The O-DU using Fronthaul M-Plane interface collects capabilities related to support for Network Energy Saving from the O-RU. The parameters that are exposed are out of scope of this specification. + 2. O-DU using O1 interface exposes to MnS Consumer its capabilities along with O-RU capabilities reported in Step #1. + 3. Via O1 interface the O-DU receives from MnS Consumer configuration needed to enable services. + 4. O-DU internally applies received configuration (assumption: the configuration is valid – otherwise scenario stops with O-DU rejecting received configuration). + 5. O-DU applies configuration to O-RU(s) using FH M-Plane interface where applicable. +- <traffic starts on air interface> +6. O-DU exposes available traffic and/or load performance and energy consumption measurements data as per its current configuration to MnS Consumer via O1 interface. + 7. MnS Consumer analyses above collected data. + 8. Based on the analysis done in Step 7, MnS Consumer optionally prepares reconfiguration for the O-CU. The way how MnS Consumer controls O-CU is out of scope of this document. + 9. O-DU receives F1 message containing list of cells to be deactivated / activated (the F1 message could also be single cell). + 10. As an alternative to Step 8, MnS Consumer optionally creates Energy Saving Policies for O-CU. The way how MnS Consumer controls O-CU is out of scope of this document. + 11. O-CU periodically checks the conditions specified in the policy are fulfilled. The way how O-CU checks the conditions stated in the policy is out of scope of this document. + 12. If policy conditions are fulfilled, O-DU optionally receives the list of cells to be activated/deactivated, which is out of scope of this document. + 13. O-DU translates between cells received in F1 message and associated carriers that serve for such cells. + 14. O-DU performs deactivation / activation of carriers in O-RU through Fronthaul (FH) interface, where those carriers determined in steps 9 and 13. + 15. The flow loops to Step #6 as shown in Figure F.1. + +![Sequence diagram for Network Energy Saving - Cell and carrier deactivation / activation use case. The diagram shows interactions between MnS Consumer, O-CU, O-DU, and O-RU. It includes steps for capability collection, configuration exchange, data evaluation, and conditional cell/carrier deactivation/activation.](a260dd6adb7b11ee98f12a299ca876b2_img.jpg) + +**Network Energy Saving - Cell and carrier deactivation / activation** + +``` + +sequenceDiagram + participant MnS as MnS Consumer + participant OCU as O-CU + participant ODU as O-DU + participant ORU as O-RU + + ODU->>ORU: 1 <<FH - M-Plane>> O-DU collects capabilities related to Energy Saving from O-RU + ODU->>MnS: 2 <<O1>> O-DU exposes its Energy Saving related capabilities along with O-RU(s) capabilities + MnS->>ODU: 3 <<O1>> O-DU receives configuration needed to enable services + ODU->>ODU: 4 O-DU uses received configuration + ODU->>ORU: 5 O-DU applies configuration where applicable + + loop + ODU->>MnS: 6 <<O1>> O-DU exposes available traffic, load, performance and energy consumption measurements as per its configuration + MnS->>ODU: 7 Collected data evaluation + end + + alt + OCU->>ODU: 8 <<O1>> Direct Cell(s) deactivation/activation + OCU->>ODU: 9 <<F1>> O-DU receives the list of cells to be deactivated/activated + OCU->>ODU: 10 <<O1>> New ESP with rules for Cell deactivation/activation use case + OCU->>ODU: 11 Periodically checks if conditions in specific policy are fulfilled + alt [Conditions fulfilled] + OCU->>ODU: 12 <<F1>> O-DU receives the list of cells to be deactivated/activated + end + end + + ODU->>ORU: 13 O-DU process the above request and translates between cells and associated carriers + ref + ODU->>ORU: <<FH>> Carrier deactivation/activation + end + +``` + +Sequence diagram for Network Energy Saving - Cell and carrier deactivation / activation use case. The diagram shows interactions between MnS Consumer, O-CU, O-DU, and O-RU. It includes steps for capability collection, configuration exchange, data evaluation, and conditional cell/carrier deactivation/activation. + +**Figure F.1: Network Energy Saving - Cell and carrier deactivation / activation use case.** + +This method shall be used to achieve energy saving by deactivating a cell(s) and its associated carriers. + +From O-DU perspective it does not matter if cell deactivation / activation request via F1 interface is received because of direct command sent to O-CU by MnS Consumer or is result of processing of the policies in the list (conditionals formed in any Energy Saving Policy in the list for cell deactivation or activation are determined as fulfilled by O-CU). In case of + +policy processing assumed is, that O-CU knows at least one Energy Saving Policy (ESP) that may lead to cell disablement / enablement. + +At O-DU level the scenario is always initiated by F1 message containing list of cells to be deactivated or activated. + +Content of such F1 message is processed by O-DU. Carriers related to cells requested in F1 message are determined. Knowing translation between cells and carriers, the O-DU requests O-RU to deactivate / activate determined [tr]x-array-carriers accordingly. + +## F.3 RF Channel Reconfiguration + +### F.3.1 Flow description + +1. The O-DU using Fronthaul M-Plane interface collects capabilities related to support for Network Energy Saving from the O-RU. The parameters that are exposed are out of scope of this specification. + 2. O-DU using O1 interface exposes to MnS Consumer its capabilities along with O-RU capabilities reported in Step #1. + 3. Via O1 interface the O-DU receives from MnS Consumer configuration needed to enable services. + 4. O-DU internally applies received configuration (assumption: the configuration is valid – otherwise scenario stops with O-DU rejecting received configuration). + 5. O-DU applies configuration to O-RU(s) using FH M-Plane interface where applicable. +- <traffic starts on air interface> +6. O-DU exposes available traffic and/or load performance and energy consumption measurements as per its current configuration to MnS Consumer via O1 interface. + 7. MnS Consumer analyses above collected data. + 8. Based on the analysis done in Step 7, MnS Consumer may optionally decide to provide O-DU with new Energy Saving Policy (ESP) with rules/conditions for RF Channel Reconfiguration + 9. O-DU may optionally receive a request from MnS Consumer to remove existing Energy Saving Policy (ESP) for RF Channel Reconfiguration. + 10. O-DU notifies the MnS Consumer to inform if request for policy addition / removal has been executed successfully. + 11. The flow loops to Step #6 as shown in Figure F.2. + +## Network Energy Saving - RF Channel Reconfiguration + +![Sequence diagram showing the common flow for Network Energy Saving use cases for RF Channel Reconfiguration between MnS Consumer, O-DU, and O-RU.](b049662c2cffb8ff53c8013d21fad304_img.jpg) + +``` + +sequenceDiagram + participant MnS as MnS Consumer + participant ODU as O-DU + participant ORU as O-RU + + ODU->>ORU: <<FH - M-Plane>> O-DU 1 collects capabilities related to Energy Saving from O-RU + ODU->>MnS: <<O1>> O-DU exposes its Energy Saving 2 related capabilities along with O-RU(s) capabilities + MnS->>ODU: 3 <<O1>> O-DU receives configuration needed to enable services + ODU->>ODU: 4 O-DU uses received configuration + ODU->>ORU: 5 O-DU applies configuration where applicable + + loop + ODU->>MnS: <<O1>> O-DU exposes available traffic, 6 load, performance and energy consumption measurements as per its configuration + MnS->>ODU: 7 Collected data evaluation + end + + opt + MnS->>ODU: 8 <<O1>> O-DU receives new ESP with rules for RF Channel Reconfiguration + ODU->>MnS: 9 <<O1>> O-DU receives request for removal of existing ESP + end + + ODU->>MnS: 10 O-DU informs MnS Consumer about status of ESP addition / removal + +``` + +The diagram illustrates the sequence of operations for RF Channel Reconfiguration. It involves three main entities: MnS Consumer, O-DU, and O-RU. The process begins with O-DU collecting capabilities from O-RU (Step 1). O-DU then exposes these capabilities to the MnS Consumer (Step 2). The MnS Consumer sends configuration to O-DU (Step 3). O-DU uses this configuration (Step 4) and applies it to O-RU (Step 5). A loop follows where O-DU reports traffic and energy measurements to the MnS Consumer (Step 6), who evaluates the data (Step 7). An optional step (opt) shows the MnS Consumer sending new ESP rules to O-DU (Step 8) and O-DU sending removal requests back (Step 9). Finally, O-DU informs the MnS Consumer of the status of ESP changes (Step 10). + +Sequence diagram showing the common flow for Network Energy Saving use cases for RF Channel Reconfiguration between MnS Consumer, O-DU, and O-RU. + +Figure F.2: Common flow for Network Energy Saving use cases for RF Channel Reconfiguration + +In this method, RF channel(s) and associated antenna array elements may be turned off / on to control energy consumption. + +High level view of RF Channel Reconfiguration sub use case using TRx Control based on policies provided by MnS Consumer to O-DU is shown in Figure F.3, which describes the following key steps. + +Option 1) TRX Control Configuration activation by C-Plane + +- When periodically processing known Energy Saving Policies, the O-DU detects those conditions for specific TRX Control configuration activation is fulfilled. + +- The O-DU using Fronthaul C-Plane Interface requests O-RU to activate specific TRX Control configuration. + +Option 2) TRX Control Configuration deactivation by C-Plane + +- When periodically processing known Energy Saving Policies, the O-DU detects those conditions for specific TRX Control configuration deactivation is fulfilled, and the O-DU knows that C-Plane can be used for deactivation. + +- The O-DU using Fronthaul C-Plane requests O-RU to deactivate specific TRX Control configuration. + +Option 3) TRX Control Configuration deactivation by M-Plane + +- When periodically processing known Energy Saving Policies, the O-DU detects those conditions for specific TRX Control configuration deactivation is fulfilled, and the O-DU knows that M-Plane shall be used for TRX Control deactivation. + +- The O-DU using Fronthaul M-Plane requests O-RU to deactivate specific TRX Control configuration. + +## High Level Overview of RF Channel Reconfiguration scenario + +![Sequence diagram showing the high-level overview of RF Channel Reconfiguration scenario between O-DU and O-RU. The diagram includes a loop structure with multiple alternative paths for policy processing and reconfiguration requests.](af0347e352bb15c70674c799ad7f9ee0_img.jpg) + +``` + +sequenceDiagram + participant O-DU + participant O-RU + Note over O-DU, O-RU: Carriers are configured and active + loop + alt [No ESP to be activated] + 1 Policy processing (conditionals, parameters not met for known policies) + else [TRX Control Configuration to be activated] + Policy processing (conditionals for specific RF Channel Reconfiguration activation are fulfilled) + 2 + 3 <<FH, C-Plane>> O-DU requests O-RU to deactivate specific TRX channel(s) of Antenna array(s) using C-Plane message with appropriate parameters + else [TRX Control Configuration to be deactivated] + Policy processing (conditionals for specific TRX Control configuration deactivation are fulfilled) + 4 + alt [TRX Control Configuration can be deactivated by C-Plane] + 5 <<FH, C-Plane>> O-DU requests O-RU to activate specific TRX channel(s) of Antenna array(s) using C-Plane message with appropriate parameters + else [TRX Control Configuration needs to be deactivated by M-Plane] + 6 <<FH, M-Plane>> O-DU requests O-RU to activate specific TRX channel(s) of Antenna array(s) using M-Plane message with appropriate parameters + end + end + end + +``` + +The diagram illustrates the high-level overview of RF Channel Reconfiguration scenario between O-DU and O-RU. It starts with a note indicating that carriers are configured and active. A loop structure follows, containing several alternative paths (alt blocks) for policy processing and reconfiguration requests. The paths include: 1. Policy processing (conditionals, parameters not met for known policies). 2. Policy processing (conditionals for specific RF Channel Reconfiguration activation are fulfilled), leading to O-DU requesting O-RU to deactivate specific TRX channel(s) of Antenna array(s) using C-Plane message with appropriate parameters. 3. Policy processing (conditionals for specific TRX Control configuration deactivation are fulfilled), leading to O-DU requesting O-RU to activate specific TRX channel(s) of Antenna array(s) using C-Plane message with appropriate parameters. 4. Policy processing (conditionals for specific TRX Control configuration deactivation are fulfilled), leading to O-DU requesting O-RU to activate specific TRX channel(s) of Antenna array(s) using M-Plane message with appropriate parameters. + +Sequence diagram showing the high-level overview of RF Channel Reconfiguration scenario between O-DU and O-RU. The diagram includes a loop structure with multiple alternative paths for policy processing and reconfiguration requests. + +Figure F.3: Network Energy Saving - RF Channel Reconfiguration use case based on policies known to O-DU + +## F.4 Advanced Sleep Modes + +### F.4.1 Flow description + +1. The O-DU using Fronthaul M-Plane interface collects capabilities related to support for Network Energy Saving from the O-RU. The parameters that are exposed are out of scope of this specification. + +2. O-DU using O1 interface exposes to MnS Consumer its capabilities along with O-RU capabilities reported in Step #1. +3. Via O1 interface the O-DU receives from MnS Consumer configuration needed to enable services. +4. O-DU internally applies received configuration (assumption: the configuration is valid – otherwise scenario stops with O-DU rejecting received configuration). +5. O-DU applies configuration to O-RU(s) using FH M-Plane interface where applicable. +<traffic starts on air interface>. +6. O-DU exposes available traffic and/or load performance and energy consumption measurements as per its current configuration to MnS Consumer via O1 interface. +7. MnS Consumer analyses above collected data. +8. Based on the analysis done in Step 7, MnS Consumer may optionally decide to provide O-DU with new Energy Saving Policy (ESP) with rules/conditions for Advanced Sleep Mode. +9. O-DU may optionally receive a request from MnS Consumer to remove existing Energy Saving Policy (ESP) for Advanced Sleep Mode. +10. O-DU notifies the MnS Consumer to inform if request for policy addition / removal has been executed successfully. +11. The flow loops to Step #6 as shown in Figure F.4. + +### Network Energy Saving - Advanced Sleep Modes + +![Sequence diagram showing Network Energy Saving - Advanced Sleep Modes use cases between MnS Consumer, O-DU, and O-RU.](b66ab6ef0e4f2cbd034f427ad9261041_img.jpg) + +``` + +sequenceDiagram + participant MnS as MnS Consumer + participant ODU as O-DU + participant ORU as O-RU + + ORU->>ODU: <<FH - M-Plane>> O-DU +1 collects capabilities related to +Energy Saving from O-RU + ODU->>MnS: <<O1>> O-DU exposes its Energy Saving +2 related capabilities along with O-RU(s) +capabilities + MnS->>ODU: 3 <<O1>> O-DU receives configuration needed to +enable services + ODU->>ODU: 4 O-DU uses received configuration + ODU->>ORU: 5 O-DU applies configuration +where applicable + loop + ODU->>MnS: <<O1>> O-DU exposes available traffic, +6 load, performance and energy consumption +measurements as per its configuration + MnS->>ODU: 7 Collected data evaluation + end + opt + MnS->>ODU: 8 <<O1>> O-DU receives new ESP with rules +for - Advanced Sleep Modes use case + ORU->>ODU: 9 <<O1>> O-DU receives request for removal of +existing ESP + end + ODU->>MnS: 10 O-DU informs MnS Consumer about status of +ESP addition / removal + +``` + +The diagram illustrates the Network Energy Saving - Advanced Sleep Modes use cases. It involves three main entities: MnS Consumer, O-DU, and O-RU. The process begins with the O-RU sending capabilities to the O-DU (Step 1). The O-DU then exposes these capabilities to the MnS Consumer (Step 2). The MnS Consumer sends configuration to the O-DU (Step 3). The O-DU uses this configuration (Step 4) and applies it to the O-RU (Step 5). A loop follows where the O-DU reports traffic and energy consumption to the MnS Consumer (Step 6), who evaluates the data (Step 7). An optional step (opt) shows the MnS Consumer sending new ESP rules to the O-DU (Step 8) and the O-RU sending a request for removal of existing ESP to the O-DU (Step 9). Finally, the O-DU informs the MnS Consumer about the status of ESP addition/removal (Step 10). + +Sequence diagram showing Network Energy Saving - Advanced Sleep Modes use cases between MnS Consumer, O-DU, and O-RU. + +**Figure F.4: Network Energy Saving use cases for Advanced Sleep Modes** + +In this method, some of the O-RU components or the whole O-RU (except circuitry and SW components needed to process M-Plane) shall be put to sleep to save energy, where the sleep should be optionally implemented at array level and/or carrier level, or O-RU level. + +High level view of Advanced Sleep Mode use case based on policies provided by MnS Consumer to O-DU is shown in Figure F.5, which describes the following key steps. + +Option 1) Advanced Sleep Mode activation by C-Plane + +1 1. When periodically processing known Energy Saving Policies, the O-DU detects that conditions for specific Sleep +2 Mode activation are fulfilled. + +3 2. The O-DU using Fronthaul C-Plane requests O-RU to activate specific Sleep Mode. +4 + +5 Option 2) Advanced Sleep Mode deactivation by C-Plane + +6 1. When periodically processing known Energy Saving Policies, the O-DU detects that conditions for specific Sleep +7 Mode deactivation are fulfilled and the O-DU knows that C-Plane must be used for Sleep Mode deactivation. + +8 2. The O-DU using Fronthaul C-Plane Interface requests O-RU to deactivate specific Sleep Mode. +9 + +10 Option 3) Advanced Sleep Mode deactivation by M-Plane + +11 1. When periodically processing known Energy Saving Policies, the O-DU detects that conditions for specific Sleep +12 Mode deactivation are fulfilled, and the O-DU knows that M-Plane must be used for Sleep Mode deactivation. + +13 2. The O-DU using Fronthaul M-Plane Interface requests O-RU to deactivate specific Sleep Mode. + +## High Level Overview of Advanced Sleep Modes + +![Sequence diagram showing the high-level overview of Advanced Sleep Modes between O-DU and O-RU. The diagram includes a pre-condition 'Carriers are configured and active', a loop structure with three main branches: 'No ESP to be activated', 'ESP for Advanced Sleep Mode to be activated', and 'ESP for Advanced Sleep Mode to be deactivated'. The 'deactivated' branch further splits into 'can be deactivated by C-Plane' and 'must be deactivated by M-Plane'.](afb637064fc23d177a87d37b08c3678f_img.jpg) + +``` + +sequenceDiagram + participant O-DU + participant O-RU + Note over O-DU, O-RU: Carriers are configured and active + loop + alt [No ESP to be activated] + O-DU->>O-DU: 1 Policy processing (conditionals not met for known policies) + else [ESP for Advanced Sleep Mode to be activated] + O-DU->>O-DU: 2 Policy processing (conditionals for specific Advanced Sleep Mode activation fulfilled) + O-DU->>O-RU: 3 <<FH, C-Plane>> O-DU requests O-RU to activate specific Advanced Sleep Mode using C-Plane message with appropriate parameters + else [ESP for Advanced Sleep Mode to be deactivated] + O-DU->>O-DU: 4 Policy processing (conditionals for specific Advanced Sleep Mode deactivation fulfilled) + alt [Advanced Sleep Mode can be deactivated by C-Plane] + O-DU->>O-RU: 5 <<FH, C-Plane>> O-DU requests O-RU to deactivate specific Advanced Sleep Mode using C-Plane message with appropriate parameters + else [Advanced Sleep Mode must be deactivated by M-Plane] + O-DU->>O-RU: 6 <<FH, M-Plane>> O-DU requests O-RU to deactivate specific Advanced Sleep Mode using M-Plane message with appropriate parameters + end + end + end + +``` + +Sequence diagram showing the high-level overview of Advanced Sleep Modes between O-DU and O-RU. The diagram includes a pre-condition 'Carriers are configured and active', a loop structure with three main branches: 'No ESP to be activated', 'ESP for Advanced Sleep Mode to be activated', and 'ESP for Advanced Sleep Mode to be deactivated'. The 'deactivated' branch further splits into 'can be deactivated by C-Plane' and 'must be deactivated by M-Plane'. + +Figure F.5: Network Energy Saving - Advanced Sleep Mode use case based on policies known to O-DU. + +1 + +# Revision History + +| Date | Revision | Author | Description | +|------------|----------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2020.09.25 | 01.00 | O-RAN-WG5 | First published version based on contributions and review by O-RAN members | +| 2021.07.08 | 02.00 | O-RAN-WG5 | Updates to v01.00 <ul style="list-style-type: none"> <li>- Security requirements alignment with O-RAN Security Focus Group document</li> <li>- Addition of new parameters for Network slicing</li> <li>- Addition of required measurements to support Slicing management and SLA assurance</li> </ul> | +| 2021.11.12 | 03.00 | O-RAN-WG5 | Updates to v02.00 <ul style="list-style-type: none"> <li>- Specification name update</li> <li>- Transport protocol chapter update – alignment with O1 interface specification</li> <li>- Interface description chapter update – alignment with O1 interface specification</li> <li>- Counters description update</li> <li>- Sync chapter update</li> <li>- PRB in RRM Policy IOC alignment with 3GPP</li> <li>- Referenced documents versions update</li> <li>- Editorial modifications</li> </ul> Additions of new functionalities <ul style="list-style-type: none"> <li>- Addition of counters to support Slicing management and SLA assurance</li> </ul> | +| 2022.03.24 | 04.00 | O-RAN-WG5 | Updates to v03.00: <ul style="list-style-type: none"> <li>- Counters description update</li> <li>- Fault events notification update</li> <li>- Fault operations update</li> <li>- Retrieval file list update</li> <li>- Startup and registration update</li> <li>- PNF Software Management clarification</li> <li>- PM File content update</li> <li>- Trace management update</li> <li>- Editorial modifications and updates</li> </ul> | +| 2022.07.21 | 05.00 | O-RAN-WG5 | Updates to v04.00: <ul style="list-style-type: none"> <li>- Corrections and updates to Performance counters table</li> <li>- Addition of “PDCCH for BWP switching” and “Distribution of Activated BWP ID” counters</li> <li>- Change the words “SSB beam index” and “SSB beam” to “SSB index” and “SSB” in Annex A Counter definition, respectively.</li> </ul> | +| 2022.11.10 | 06.00 | O-RAN-WG5 | Updated to v05.00: <ul style="list-style-type: none"> <li>- Typographical corrections in Performance counters tables</li> <li>- Updated WG5 M-Plane with related terminology according to context</li> <li>- Remove chapter 10.5</li> <li>- Editorial updates</li> <li>- Filename change to show O-RAN release number</li> </ul> | +| 2023.03.08 | 07.00 | O-RAN-WG5 | Updated to v.06.00: <ul style="list-style-type: none"> <li>- Shared O-RU introduction</li> <li>- Added mentions of 5QI to particular PM counters</li> <li>- Editorial fixes</li> </ul> | + +2 + +3 + +1 + +| | | | | +|------------|-------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.07.20 | 08.00 | O-RAN-WG5 | Updated to v.07.00: <ul style="list-style-type: none"> <li>- Updated PM Counters.</li> <li>- <math>I_{MCS}</math> updated to max value 28 for some counters.</li> <li>- Clauses renumbered.</li> <li>- Updates to list available files clause.</li> <li>- Figures renumbered.</li> <li>- O-DU Architecture model text updated.</li> <li>- References section cleanup and split to normative and informative</li> <li>- Editorial corrections</li> </ul> | +| 2023.11.07 | 09.00 | O-RAN-WG5 | Updated to v08.00: <ul style="list-style-type: none"> <li>- Addition of Attributes definitions table</li> <li>- Annex A. 11.30.1 Fixed UL to DL in Condition section</li> <li>- Added 3GPP Conformance testing clause and Annex E</li> <li>- Updates to counters defined in A.1.14, A.1.15, A.11.31, A.11.32, A.11.33, A.11.34, A.11.35, A.11.37, A.11.38, A.11.39</li> <li>- Addition of counters in A.2.23, A.2.24, A.4.5, A.4.6, A.9.7, A.12.10</li> <li>- Editorial updates according to comments</li> <li>- Added Information Models for NES</li> </ul> | + +2 \ No newline at end of file diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/06e6d06ada4b30077ea020785b04edfc_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/06e6d06ada4b30077ea020785b04edfc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cefe2a113dd46e6dff4173154f641ac10b37365e --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/06e6d06ada4b30077ea020785b04edfc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5e653a7cf5823ab1034a8814af68db7a13549c2750e04cfe4eb530e43a87368c +size 4491 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/3f9b4b1815e089b5a1321a1a9b44ede4_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/3f9b4b1815e089b5a1321a1a9b44ede4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6adbbefaf8a438bdf0ac964042b4c8f403c6459f --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/3f9b4b1815e089b5a1321a1a9b44ede4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce6ac3089ae9d68fa3f922b11254b2009f5d39351a1e4bc1bb6364c4b8451626 +size 4543 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/47a9b5da0a7bf7dcb47bcb3b671c2124_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/47a9b5da0a7bf7dcb47bcb3b671c2124_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4ce74cc2f590a21bc7986a5d0844cc9baf575fa5 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/47a9b5da0a7bf7dcb47bcb3b671c2124_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c287364eb0f75be7051bbc2259804ed93025f3e92036de05447bdb08661c84d2 +size 52677 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/90e5db0659c274459925aa036940950b_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/90e5db0659c274459925aa036940950b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9281053dc2d9396ab5944bfea4a74dfa1b1a4d34 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/90e5db0659c274459925aa036940950b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:320660b436e81f5f4946f264d213d44f35b375daf826637730df489449377269 +size 60175 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/ba21220e48c5b5967c4ae64d7785e30d_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/ba21220e48c5b5967c4ae64d7785e30d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..baf323b28a1615b72ac89fed301fda1a15a9d12d --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/ba21220e48c5b5967c4ae64d7785e30d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f74bb370537fc3ae76187be238566a85a39bd5145d0586b4971b664af457ad12 +size 39139 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG5/O-RAN.WG5.Transport.0-v01.00/raw.md b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..fd848c64ce351a94e35555ad645903a423be1f2e --- /dev/null +++ b/marked/WG5/O-RAN.WG5.Transport.0-v01.00/raw.md @@ -0,0 +1,630 @@ + + +# **O-RAN Open F1/W1/E1/X2/Xn Interfaces Working Group****Transport Specification** + +--- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Open F1/W1/E1/X2/Xn Interfaces Working Group****Transport Specification** --- + +Prepared by the O-RAN Alliance. Copyright © 2020 by the O-RAN Alliance. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in Annex *ZZZ* of this specification. All other rights reserved. + +1 + +# --- Revision History + +| Date | Revision | Author | Description | +|------------|----------|-------------------------|------------------------------| +| 2020.03.09 | 1.00 | Ole Reinartz<br>(Nokia) | First published version 1.00 | +| | | | | + +--- + +2 + +3 + +# Contents + +| | | +|--------------------------------------------------------|----| +| Revision History..... | 2 | +| 1 Scope..... | 4 | +| 2 References..... | 5 | +| 3 Definitions and abbreviations ..... | 7 | +| 3.1 Definitions..... | 7 | +| 3.2 Abbreviations ..... | 7 | +| 4 Interface classification ..... | 8 | +| 4.1 General ..... | 8 | +| 4.2 Class 1: Basic network interoperability ..... | 8 | +| 4.2.1 Network Layer Interface (layer 3)..... | 8 | +| 4.2.2 Transport Layer Interface (layer 4) ..... | 11 | +| 4.2.3 Security..... | 11 | +| 4.3 Class 2: UNI type interfaces..... | 13 | +| 4.3.1 Class 2.1: Ethernet..... | 14 | +| 4.3.2 Class 2.2: [Vn-Nf]/N/L3 Service..... | 15 | +| 5 Annex ZZZ : O-RAN Adopter License Agreement..... | 15 | +| Section 1: DEFINITIONS ..... | 15 | +| Section 2: COPYRIGHT LICENSE ..... | 16 | +| Section 3: FRAND LICENSE..... | 16 | +| Section 4: TERM AND TERMINATION ..... | 17 | +| Section 5: CONFIDENTIALITY..... | 17 | +| Section 6: INDEMNIFICATION..... | 17 | +| Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 17 | +| Section 8: ASSIGNMENT ..... | 18 | +| Section 9: THIRD-PARTY BENEFICIARY RIGHTS ..... | 18 | +| Section 10: BINDING ON AFFILIATES..... | 18 | +| Section 11: GENERAL ..... | 18 | + +# 1 Scope + +This document complements existing standards specific for F1-, W1-, E1-, X2- and Xn- transport (currently TS 38.472 [1], TS 38.474 [23], TS 36.424 [22], TS 38.462 [48] and TS 36.422 [21]) as they apply to O-CU and O-DU. + +![Figure 1: Interfaces covered by ORAN WG5. The diagram shows two main components on the left: eNB and DU, and one on the right: CU. All are connected to a central 'Transport network (IP network)'. The eNB and DU both have a 'Transport function' block containing 'L4(UDP,SCTP,etc.)', 'Security(IPsec etc.)', 'L3(IP)', and 'L2(Ethernet)'. The CU also has a 'Transport function' block with the same layers. A green double-headed arrow labeled 'X2' connects the eNB's transport function to the CU's. A green double-headed arrow labeled 'F1' connects the DU's transport function to the CU's.](47a9b5da0a7bf7dcb47bcb3b671c2124_img.jpg) + +Figure 1: Interfaces covered by ORAN WG5. The diagram shows two main components on the left: eNB and DU, and one on the right: CU. All are connected to a central 'Transport network (IP network)'. The eNB and DU both have a 'Transport function' block containing 'L4(UDP,SCTP,etc.)', 'Security(IPsec etc.)', 'L3(IP)', and 'L2(Ethernet)'. The CU also has a 'Transport function' block with the same layers. A green double-headed arrow labeled 'X2' connects the eNB's transport function to the CU's. A green double-headed arrow labeled 'F1' connects the DU's transport function to the CU's. + +**Figure 1 Interfaces covered by ORAN WG5** + +Note: at the time of writing only F1- and X2- interfaces are covered by ORAN WG5 specifications. + +It also covers transport aspects relevant for M-plane and S-plane. In addition, it defines a number of support classes. + +Differences to referred standards are explicitly noted throughout the document. + +## ORAN WG5 Transport + +![Figure 2: ORAN WG5 Transport architecture. It shows an O-DU Node (yellow) on the left and an O-CU Node (blue) on the right, both connected to a central Transport network (grey). The O-DU Node has a 'Transport function' block with 'IPsec', 'IP', 'Ethernet', and 'Phy' layers. The O-CU Node has a 'Transport function' block with the same layers. The Transport network contains 'PE node' and 'P nodes' (IP network). Arrows indicate connections: 'e2e IP' from O-DU to PE node, 'UNI Ethernet' from PE node to O-CU, and 'e2e IP' from O-CU to PE node. Callouts point to various standards: IEEE 802.1 & IEEE 802.3 YANG (pointing to Ethernet), 3GPP 38. series (pointing to IPsec), ITU-T info models (pointing to IP), MEF 22.3 (pointing to Ethernet), IETF (pointing to IP network), and Class 1 and Class 2.1 (pointing to the O-CU Node).](90e5db0659c274459925aa036940950b_img.jpg) + +Figure 2: ORAN WG5 Transport architecture. It shows an O-DU Node (yellow) on the left and an O-CU Node (blue) on the right, both connected to a central Transport network (grey). The O-DU Node has a 'Transport function' block with 'IPsec', 'IP', 'Ethernet', and 'Phy' layers. The O-CU Node has a 'Transport function' block with the same layers. The Transport network contains 'PE node' and 'P nodes' (IP network). Arrows indicate connections: 'e2e IP' from O-DU to PE node, 'UNI Ethernet' from PE node to O-CU, and 'e2e IP' from O-CU to PE node. Callouts point to various standards: IEEE 802.1 & IEEE 802.3 YANG (pointing to Ethernet), 3GPP 38. series (pointing to IPsec), ITU-T info models (pointing to IP), MEF 22.3 (pointing to Ethernet), IETF (pointing to IP network), and Class 1 and Class 2.1 (pointing to the O-CU Node). + +Pls note that the above documents in turn point to IETF, ITU, IEEE documents for the specific protocols + +**Figure 2 ORAN WG5 Transport** + +As stated above, while this document does not make requirement to the transport networks between O-DUs and O-CUs, Figure 2 also indicates existing standards documents making requirements to such transport + +networks that are possible to be used between O-DU and O-CUs, i.e. MEF 22.3, BBF TR-221,224,350 and WT-521. + +# 2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 15. + +- [1] 3GPP TS 38.472 V15.5.0: "F1 signalling transport (Release 15)". +- [2] IEEE 802.1Q-2018: "IEEE Standard for Local and metropolitan area networks— Bridges and Bridged Networks" +- [3] IETF RFC 2474: "Definition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 Headers" +- [4] IETF RFC 2598: "An Expedited Forwarding PHB" +- [5] IETF RFC 2597: "Assured Forwarding PHB Group" +- [6] IETF RFC 4594: "Configuration Guidelines for DiffServ Service Classes" +- [7] IETF RFC 826: "An Ethernet Address Resolution Protocol -- or -- Converting Network Protocol Addresses" +- [8] IETF RFC 792: "INTERNET CONTROL MESSAGE PROTOCOL" +- [9] IETF RFC 8200: "Internet Protocol, Version 6 (IPv6) Specification" +- [10] IETF RFC 4861: "Neighbor Discovery for IP version 6 (IPv6)" +- [11] IETF RFC 4443: "Internet Control Message Protocol (ICMPv6) for the Internet Protocol Version 6 (IPv6) Specification" +- [12] IETF RFC 6890: "Special-Purpose IP Address Registries" +- [13] IETF RFC 8190: "Updates to the Special-Purpose IP Address Registries" +- [14] IETF RFC 2131: "Dynamic Host Configuration Protocol" +- [15] IETF RFC 4361: "Node-specific Client Identifiers for Dynamic Host Configuration Protocol Version Four (DHCPv4)" +- [16] IETF RFC3315: "Dynamic Host Configuration Protocol for IPv6 (DHCPv6)" +- [17] IETF RFC4862: "IPv6 Stateless Address Autoconfiguration" +- [18] IETF RFC768: "User Datagram Protocol" +- [19] 3GPP TS 29.060 V15.0.0: "GPRS Tunnelling Protocol (GTP) across the Gn and Gp interface (Release 15)" + +| | | | +|----|------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | [20] | 3GPP TS 29.274 V16.1.0: “GPRS Tunnelling Protocol (GTP) across the Gn and Gp interface (Release 15)” | +| 2 | | | +| 3 | [21] | 3GPP TS TS 36.422 version 15.1.0: “X2 signalling transport (Release 15)” | +| 4 | [22] | 3GPP TS TS 36.424 version 15.0.0: “X2 data transport (Release 15)” | +| 5 | [23] | 3GPP TS 38.474 V15.3.0: “F1 data transport (Release 15)”. | +| 6 | [24] | 3GPP TS 33.117 V16.2.0: “Catalogue of general security assurance requirements (Release 16)” | +| 7 | | | +| 8 | [25] | IETF RFC 2119: “Key words for use in RFCs to Indicate Requirement Levels” | +| 9 | [26] | IEEE 802.3-2018: “IEEE Standard for Ethernet” | +| 10 | [27] | IETF RFC 791: “INTERNET PROTOCOL” | +| 11 | [28] | IETF RFC 1918: “Address Allocation for Private Internets” | +| 12 | [29] | IETF RFC 5357: “A Two-Way Active Measurement Protocol (TWAMP)” | +| 13 | [30] | IETF RFC 4656: “A One-way Active Measurement Protocol (OWAMP)” | +| 14 | [31] | ITU-T G.8013/Y.1731(08/2015): “Operation, administration and maintenance (OAM) functions and mechanisms for Ethernet-based networks” | +| 15 | | | +| 16 | [32] | IETF RFC 4960: “Stream Control Transmission Protocol” | +| 17 | [33] | 3GPP TS 29.281 V15.6.0: “General Packet Radio System (GPRS) Tunnelling Protocol User Plane (GTPv1-U) (Release 15)” | +| 18 | | | +| 19 | [34] | IETF RFC 1034: “DOMAIN NAMES - CONCEPTS AND FACILITIES” | +| 20 | [35] | IETF RFC 1035: “DOMAIN NAMES - IMPLEMENTATION AND SPECIFICATION” | +| 21 | [36] | IETF RFC 4210: “Internet X.509 Public Key Infrastructure Certificate Management Protocol (CMP)” | +| 22 | | | +| 23 | [37] | IETF RFC 6083: “Datagram Transport Layer Security (DTLS) for Stream Control Transmission Protocol (SCTP)” | +| 24 | | | +| 25 | [38] | 3GPP TS 33.501 V15.6.0: “Security architecture and procedures for 5G system (Release 15)” | +| 26 | | | +| 27 | [39] | IETF RFC 4301: “Security Architecture for the Internet Protocol” | +| 28 | [40] | 3GPP TS 33.210 V16.2.0: “Network Domain Security (NDS); IP network layer security (Release 16)” | +| 29 | | | +| 30 | [41] | 3GPP TS 33.310 V16.2.0: “Network Domain Security (NDS); Authentication Framework (AF) (Release 16)” | +| 31 | | | +| 32 | [42] | 3GPP TS 33.401 V16.0.0: “3GPP System Architecture Evolution (SAE); Security architecture (Release 15)” | +| 33 | | | +| 34 | [43] | 3GPP TR 33.821 V9.0.0: “Rationale and track of security decisions in Long Term Evolved (LTE) RAN / 3GPP System Architecture Evolution (SAE) (Release 9)” | +| 35 | | | +| 36 | [44] | IETF RFC 4303: “IP Encapsulating Security Payload (ESP)” | +| 37 | [45] | IETF RFC 8221: “Cryptographic Algorithm Implementation Requirements and Usage Guidance for Encapsulating Security Payload (ESP) and Authentication Header (AH)” | +| 38 | | | + +- [46] IETF RFC 7296: “Internet Key Exchange Protocol Version 2 (IKEv2)” +- [47] ETSI GS NFV-INF 005 V1.1.1 (2014-12): Network Functions Virtualisation (NFV); Infrastructure; Network Domain +- [48] 3GPP TS 38.462 V15.5.0: “E1 signalling transport (Release 15)” +- [49] MEF 22.3: “Transport Services for Mobile Networks, January 2018” +- [50] 3GPP TS 29.303 V16.0.0: “Domain Name System Procedures; Stage 3 (Release 16)” + +# 3 Definitions and abbreviations + +## 3.1 Definitions + +The key words "**SHALL**", "**SHALL NOT**", "**SHOULD**", "**SHOULD NOT**", "**MAY**", and "**OPTIONAL**" in this document are to be interpreted as described in IETF RFC 2119 [25]. All key words must be in upper case, bold text. + +Items that are **REQUIRED** (contain the words **SHALL** or **SHALL NOT**) will be labeled as **[Rx]** for required. Items that are **RECOMMENDED** (contain the words **SHOULD** or **SHOULD NOT**) will be labeled as **[Dx]** for desirable. Items that are **OPTIONAL** (contain the words **MAY** or **OPTIONAL**) will be labeled as **[Ox]** for optional. + +Items, if supported, are not meant to be active at all times, but should be available for use. Their state (active or not active) should be based on configuration. + +In this document the phrase ‘equipment’ generally refers to entities implementing F1- and/or X2- interfaces. + +## 3.2 Abbreviations + +Abbreviations defined in this document take precedence over the definition of 3GPP + +| | | +|------|-------------------------------------------| +| ARP | Address Resolution Protocol | +| CBS | committed burst size | +| CIR | committed information rate | +| DHCP | Dynamic Host Configuration Protocol | +| DSCP | Differentiated Services Codepoint | +| ICMP | Internet Control Message Protocol | +| MAC | Media Access Control | +| OAM | Operation, Administration and Maintenance | +| O-CU | O-RAN Central Unit | +| O-DU | O-RAN Distributed Unit | +| PHB | Per-hop behaviour | +| QoS | Quality of Service | +| TBD | To Be Defined | + +FFS For Further Study + +# 4 Interface classification + +## 4.1 General + +This chapter provides for a classification of Interface types, grouping different sets of mandatory features according to them into interface classes. + +## 4.2 Class 1: Basic network interoperability + +This class provides mandatory support for basic network interoperability. + +### 4.2.1 Network Layer Interface (layer 3) + +This section complies with and reuses the relevant parts of 3GPP TS 38.472 [1], TS 38.474 [23], TS 36.424 [22] and TS 36.422 [21]. + +#### 4.2.1.1 IP version 4 + +##### 4.2.1.1.1 General + +**[R1]:** IP version 4 **SHALL** be supported according to RFC791 [27] and RFC1918 [28]. + +Note: Address ranges specified in [28] are commonly used in operator networks. + +**[R2]:** O-RAN equipment **SHALL NOT** send IPv4 packets with any IPv4 header option field. If the IPv4 header option field is detected in the received packet, the contents of this option field **SHALL** be ignored at the receiving equipment. + +**[R3]:** IP addresses **SHALL** be supported on + +- Logical interfaces: network interfaces that do not have a physical representation, e.g. Ethernet VLAN terminations +- Physical interfaces: Network interfaces that have a physical representation, e.g. a Network Interface Controller (a.k.a. plain Ethernet interfaces) +- Virtual IP interfaces (loopback interfaces). These IP addresses are not attached to any network interface + +These may be located in the same or in different subnets. + +**[R4]:** For a particular Network Interface Controller IP addresses **SHALL** be supported on either the physical or the logical interface(s). + +**[R5]:** The resolution of Ethernet MAC addresses is done via ARP according to [7]. + +##### 4.2.1.1.2 ICMP for IPv4 + +**[R6]:** The equipment **SHALL** support the function of sending and receiving ICMP according to [8]. Clause 4.2.4.1.1.2 in [24] shall generally be adhered to, with the differences as defined in [R7]: + +**[R7]:** The following message types **SHALL** be supported: + +- destination unreachable ('Permitted' in [24]) + +- time exceeded with Code field=1 ('Optional' in [24])<sup>1</sup> +- echo request/reply (echo request 'Permitted' and echo reply 'Optional' in [24]) + +**[R8]:** The following message types **SHALL NOT** be supported, i.e. shall never be sent, and shall be discarded (existence of packet may be logged) when received: + +- Source quench (not listed in [24]) +- Information request/reply (not listed in [24]) + +**[O1]** The support of all other types of ICMP messages is optional. + +**[R9]:** Depending on the type of the received ICMP message the equipment **SHALL** terminate the ICMP messages, create and send the correct responses, or drop it. Incoming fragmented ICMP messages will be reassembled as necessary. + +**[R10]:** For IPsec tunnels ICMP messages towards and from inner IP address and outer IP address **SHALL** be supported. + +##### 4.2.1.1.3 DHCPv4 + +**[D1]** DHCP according to [14] **SHOULD** be supported. In addition, the equipment **SHOULD** support the behavior specified in [15], using stable DHCPv4 node identifiers in their dhcp-client-identifier option. + +#### 4.2.1.2 IP version 6 + +##### 4.2.1.2.1 General + +**[D2]** IP version 6 **SHOULD** be supported according to [9]. + +If IP version 6 is supported, + +**[R11]:** All header fields **SHALL** be supported. + +**[R12]:** The following extension headers **SHALL** be supported: + +- Fragment Header +- Encapsulating Security Payload Header +- Hop-by-Hop Options Header +- No Next header + +**[R13]:** IP addresses **SHALL** be supported on + +- Logical interfaces: network interfaces that do not have a physical representation, e.g. Ethernet VLAN terminations +- Physical interfaces: Network interfaces that have a physical representation, e.g. a Network Interface Controller (a.k.a. plain Ethernet interfaces) +- Virtual IP interfaces (loopback interfaces). These IP addresses are not attached to any network interface + +These may be located in the same or in different subnets. + +**[R14]:** For a particular interface, IP addresses **SHALL** be supported on either the physical or the logical interface(s). + +##### 4.2.1.2.2 ICMP for IPv6 + +If IP version 6 is supported, + +<sup>1</sup> The Time Exceeded message with Code 1 is used to report a fragment reassembly timeout, as specified in [8] + +**[R15]:** The equipment **SHALL** support the function of sending and receiving ICMPv6 according to [11] and Neighbor Discovery as defined in [10]. Clause 4.2.4.1.1.2 in [24] shall generally be adhered to, with the differences as defined in [R16]:. + +**[R16]:** The following message types **SHALL** be supported: + +- neighbor solicitation/advertisement +- router solicitation +- router advertisement (only receive) +- destination unreachable +- time exceeded with Code field=1 <sup>2</sup> +- echo request/reply + +**[R17]:** Depending on the type of the received ICMPv6 message the equipment **SHALL** terminate the ICMP messages, create and send the correct responses, or drop it. Incoming fragmented ICMPv6 will be reassembled as necessary. + +**[O2]** The support of all other types of ICMPv6 messages is **OPTIONAL**. + +**[R18]:** For IPsec tunnels ICMPv6 messages towards and from inner IP addresses and outer IP addresses **SHALL** be supported. + +##### 4.2.1.2.3 DHCPv6 + +**[D3]** DHCP according to [16] **SHOULD** be supported. + +##### 4.2.1.2.4 SLAAC + +**[D4]** SLAAC according to [17] **SHOULD** be supported. + +#### 4.2.1.3 Address space + +**[R19]:** The whole IP address space **SHALL** be supported by all O-RAN nodes. However, the special purpose of some IP ranges as defined in [12] (updated by [13]) **SHALL** be respected. + +#### 4.2.1.4 Packet marking + +**[R20]:** IP packets **SHALL** be marked with up to 64 different DSCP values according to [3], as also defined in [23] section 5.3 and [1] section 6. + +#### 4.2.1.5 Traceroute + +**[R21]:** Traceroute based on UDP **SHALL** be supported by the equipment. Traceroute is done at the indication from the m-plane application. A sequence of UDP packets is being sent, with the TTL of first packet being set to 1. This field is gradually incremented, usually with every third packet sent. + +**[R22]:** The Source IP address **SHALL** be indicated by the m-plane application and **SHALL** be one of the addresses assigned to the equipment. + +#### 4.2.1.6 Network OAM + +##### 4.2.1.6.1 TWAMP + +**[D5]** TWAMP according to [29] **SHOULD** be supported, or its variant TWAMP-light as defined in Appendix 1 of [29]. + +<sup>2</sup> The Time Exceeded message with Code 1 is used to report a fragment reassembly timeout, as specified in [11] + +##### 4.2.1.6.2 OWAMP + +**[D6]** OWAMP according to [30] **SHOULD** be supported. + +##### 4.2.1.6.3 ITU-T Y.1731 + +**[D7]** ITU-T Recommendation G.8013/Y.1731 according to [31] **SHOULD** be supported. + +**[D8]** Support should be limited to: + +- Ethernet continuity check (ETH-CC) ([31] section 7.1) +- Ethernet loopback (ETH-LB) ([31] section 7.2) +- Ethernet link trace (ETH-LT) ([31] section 7.3) + +**[O2]** All features not listed in [D8] are **OPTIONAL**. + +#### 4.2.1.7 Network layer setup + +**[R23]:** Networking parameters (IP addresses, IP routing entries, ...) **SHALL** be assigned to interfaces based on one of the following methods, with 1. at the highest and 4. at the lowest priority: + +1. Manual assignment +2. SLAAC (IP address, default route) with optional DHCPv6-support for additional parameters +3. DHCPv6 +4. DHCPv4 + +Note: a more detailed automatic setup procedure is FFS. + +### 4.2.2 Transport Layer Interface (layer 4) + +#### 4.2.2.1 UDP + +**[R24]:** UDP **SHALL** be supported according to [18], as defined in [22] and [23]. + +#### 4.2.2.2 SCTP + +**[R25]:** SCTP **SHALL** be supported according to [32], as defined in [1], section 7. + +**[R26]:** A node **SHALL** support a single SCTP association per node pair + +**[D9]** Multiple SCTP associations per node pair **SHOULD** be supported. + +**[R27]:** The minimum size of the receive buffer per socket shall be 128 Kilobytes. + +**[R28]:** The SCTP implementation **SHALL** allow any endpoint to be the initiator of an SCTP association. + +Note: the application should define client- and server role of an SCTP association. + +#### 4.2.2.3 PTP + +The content of this section is FFS. + +#### 4.2.2.4 GTP-U + +**[R29]:** GTP-U **SHALL** be supported according to [33]. + +#### 4.2.2.5 DNS + +**[D10]** DNS according to [50] **SHOULD** be supported. + +### 4.2.3 Security + +#### 4.2.3.1 PKI + +**[D11]** A Public Key Infrastructure according to [36] **SHOULD** be supported. + +#### 4.2.3.2 DTLS + +**[R30]:** DTLS according to [37] **SHALL** be supported for the SCTP association(s) of the F1-C interface, as defined in [38] subsections 9.8.2, 9.8.3 and 9.4. + +#### 4.2.3.3 IPsec + +##### 4.2.3.3.1 Overview + +The security of the F1/W1/E1/X2/Xn - interface control, user, synchronization and management plane protocols is increased by providing encryption, integrity protection and communication peer authentication with IPsec according [39]. IPsec can be applied to all IP traffic. It is possible to enable / disable IPsec and to configure IPsec connections to peer-entities independently in terms of security settings for each remote IPsec peer, e.g. per neighbor node or per plane. Further, it is possible to define connections to remote peers which shall not be covered by IPsec although IPsec is enabled (bypassing traffic). + +The supported IPsec capabilities follow [40] for interworking purposes and further appliance rules given in [41], [42], [38] and [43]. Since IPsec standards include a high number of selectable security parameters options, 3GPP has recommended to cut down the number of these options in order to guarantee interoperability between different security domains. + +##### 4.2.3.3.2 Supported IPsec capabilities + +**[R31]: Services that SHALL be supported (see also [38], section 9.8.2):** + +- Confidentiality, can be enabled/disabled (via ENCR\_NULL) +- integrity protection, always enabled +- data origin authentication, always enabled +- anti-replay protection, can be enabled/disabled +- extended sequence numbers, can be enabled/disabled + +**[R32]: Protocol that SHALL be supported: ESP ([44], as profiled by [40])** + +- IPsec mode: Tunnel mode +- for encrypted packets the DSCP value of the inner packet will be copied to the outer packet +- NAT traversal + +**[R33]: ESP encryption transforms that SHALL be supported (including authenticated encryption transforms, see also [40], section 5.3.3):** + +- as in [45] (the ones marked with ‘MUST’) + +**[R34]: ESP authentication transforms that SHALL be supported:** + +- as in [45] (the ones marked with ‘MUST’ or “MUST-”) +- AES-GMAC with AES-128 shall be supported. +- NULL authentication algorithm is explicitly not allowed for use, unless an authenticated encryption algorithm is used. + +**[R35]: Identification that SHALL be supported:** + +- IP address + +- Fully Qualified domain name (FQDN) (if DNS is supported) + +###### **[R36]: Authentication that SHALL be supported:** + +- Pre-shared Keys +- Digital certificates in X.509v3 format provided by a Certificate Authority solution. (optional) + +###### **[R37]: Key exchange that SHALL be supported:** + +- IKEv2 (RFC 4306) +- profile as described in [41] +- certificate-based authentication according to [41] +- certificates according to the profile described by [41] +- DH groups 14 and 19 + +###### **[R38]: Security Association multiplicity that SHALL be supported:** + +- multiple IKE SAs (multiple IPsec tunnels) +- multiple IPsec SAs +- multiple IPsec SAs per IPsec tunnel + +**[R39]:** IKE SA(s) and IPSEC SA(s) **SHALL** be regularly re-established. + +**[R40]:** When the full sequence number space of an IPSEC SA(s) is used, the transmission for that SA **SHALL** stop. + +**[R41]:** Dead-Peer-Detection (DPD) **SHALL** be supported as defined in [46]. + +**[R42]:** Each node **SHALL** support a traffic narrowing function for the traffic selector ([46]): If the traffic selector notified from the peer (e.g. Security GW or neighboring node) is wider than the Local/Remote Address range in the SPD information set on the node side, the peers set the traffic selector values to the narrower range. + +##### 4.2.3.3.3 Parallel usage of IPsec and other secure transport protocols + +**[R43]:** The equipment **SHALL** support configuration of IPsec (one or more dedicated connections) in parallel with other secure transport protocols like SSH. +For instance, it is possible to run SSH connections within an IPsec tunnel or in parallel to IPsec tunnel(s). + +##### 4.2.3.3.4 Responder mode and Initiator/Responder mode support + +**[R44]:** The equipment **SHALL** support a configurable option per IKE Security Association to use "Responder mode" instead of "Responder/Initiator mode". +The mode is related to IKE SA establishment only. The introduction of "Responder mode" does not change the IKE SA rekeying behavior: Each node operates as initiator and responder in IKE\_SA rekeying. + +## 4.3 Class 2: UNI type interfaces + +**[R45]:** Support of this class **SHALL** include all mandatory features supported in class 1. + +### 4.3.1 Class 2.1: Ethernet + +#### 4.3.1.1 Data link layer Interface (layer 2) + +##### 4.3.1.1.1 General + +- [R46]: The only data link layer to be supported **SHALL** be Ethernet as defined in IEEE 802.3-2018 [26] +- [R47]: The supported frame format **SHALL** be Ethernet frame with type interpretation of the type length field (see [2] section 3). The Length-interpretation and multiplexing data with LLC (IEEE 802.2 LLC standard) **SHALL NOT** be supported. +- [R48]: The Ethernet termination feature **SHALL** support frames with an MTU (i.e. Ethernet SDU) of up to 1500 bytes as in [2], Section 3.2.7 item a). +- [D12] The Ethernet termination feature **SHOULD** support frames with an MTU (i.e. Ethernet SDU) of 1982 bytes as in [2], Section 3.2.7 item c).<sup>3</sup> +- [R49]: A single VLAN tag for the traffic (i.e. a C-VLAN tag) **SHALL** be supported according to IEEE 802.1Q-2018 [2]. +- [R50]: Priority tagged frames (i.e. frames tagged with VLAN ID=0) **SHALL** always be received, as required by the standard. +- [O2] Transmitting priority tagged frames is **OPTIONAL**. +- [O3] The UNI to a transport network depicted in Figure 2, specified in MEF 22.3 [49] and amended by MEF 22.3.1, **MAY** be supported. + +##### 4.3.1.1.2 QoS Marking + +- [R51]: VLAN- tagged frames **SHALL** be marked with up to 8 different PCP values (see [2] for details on the PCP field), to allow for proper traffic scheduling in a VLAN- aware Ethernet network. + +##### 4.3.1.1.3 Packet Queuing, -scheduling and -shaping + +- [R52]: Traffic Queuing and -scheduling **SHALL** be provided for outgoing traffic. At the minimum, a single stage of queuing/scheduling per outgoing interface **SHALL** be supported. +- [D13] Traffic shaping **SHOULD** be provided for outgoing traffic. At the minimum, a single stage of shaping per outgoing interface **SHOULD** be supported. +- [D14] Scheduling/shaping **SHOULD** account for all bytes of the IP packet. +- [R53]: Scheduling/shaping **SHALL** account for all bytes of the Ethernet frame, including Ethernet header and FCS. +- [R54]: Schedulers **SHALL** support at least 6 different per-hop behaviours (PHB): +- EF: at least one class of Expedited Forwarding PHB (Defined in [4]) + - AF1-4: 4 classes of Assured Forwarding PHB (Defined in [5]) + - BE: Default PHB (Defined in [3]) +- [R55]: PHBs **SHALL** be selected based on the DSCP value of the packet. +- [D15] PHBs **SHOULD** be selected based on the PCP values of the frame. +- [R56]: The scheduling discipline to be supported by the scheduler **SHALL** be priority queuing and, if supported, rate queuing as defined in [6], where AF1-4 are scheduled using either a priority or a rate queuing scheduling discipline. The result of this scheduling discipline, EF and BE are being scheduled using the priority queuing discipline with EF scheduled at the highest priority and BE scheduled at the lowest priority. + +<sup>3</sup> This does not preclude equipment supporting Ethernet SDUs larger than that. + +![Figure 3: Example structure of scheduling disciplines (L2). The diagram shows a flow from left to right. On the left, there are four inputs: EF (E-Plane Function), AF1, AF2, AF3, and AF4. These inputs feed into a large blue trapezoidal block labeled 'Priority Scheduler or Rate Scheduler (WFQ, WRR, etc.)'. This block has three outputs: 'high', 'medium', and 'low'. The 'high' output goes to a second large blue trapezoidal block labeled 'Priority Scheduler'. The 'medium' and 'low' outputs also go to this second block. The output of the second block goes to a third, smaller blue trapezoidal block labeled 'Traffic Shaper (optional)'. Finally, the output of the third block goes to the right.](ba21220e48c5b5967c4ae64d7785e30d_img.jpg) + +Figure 3: Example structure of scheduling disciplines (L2). The diagram shows a flow from left to right. On the left, there are four inputs: EF (E-Plane Function), AF1, AF2, AF3, and AF4. These inputs feed into a large blue trapezoidal block labeled 'Priority Scheduler or Rate Scheduler (WFQ, WRR, etc.)'. This block has three outputs: 'high', 'medium', and 'low'. The 'high' output goes to a second large blue trapezoidal block labeled 'Priority Scheduler'. The 'medium' and 'low' outputs also go to this second block. The output of the second block goes to a third, smaller blue trapezoidal block labeled 'Traffic Shaper (optional)'. Finally, the output of the third block goes to the right. + +**Figure 3 Example structure of scheduling disciplines (L2)** + +**[R57]:** If implemented, the traffic shaping functionality **SHALL** allow to configure an average rate (CIR: committed information rate) and a burst size (CBS: committed burst size) to be committed. Range and granularity of these parameters depend on the implementation. In its default state (i.e. without any configuration done) the traffic shaping function **SHALL** be inactive. + +### 4.3.2 Class 2.2: [Vn-Nf]/N/L3 Service + +**[D16]** A VNF **SHOULD** be able to use the network services provided by the Vn-Nf/N/L3 service as defined in [47] subsection 5.1.1.2. + +# 5 Annex ZZZ : O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise + +licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an ORAN Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter’s distributors and the use by the Adopter’s customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any + +Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of ORAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, + +CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance's sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. + +Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or third party beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full force and effect. \ No newline at end of file diff --git a/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/10418bccbde60b8b99bda8f0e4bc2664_img.jpg b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/10418bccbde60b8b99bda8f0e4bc2664_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..28c92ed459b2441d5842684f297f5b4388b3025f --- /dev/null +++ b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/10418bccbde60b8b99bda8f0e4bc2664_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf557bfae3142b282b746d438cbbbefc6d4e75bfec170733839ad90f11c18887 +size 30317 diff --git a/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/856f0d4d6b96c90e511f7b8386e51811_img.jpg b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/856f0d4d6b96c90e511f7b8386e51811_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f2a55817c28abc182f1d2489efbf411c14f5d955 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/856f0d4d6b96c90e511f7b8386e51811_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0502c8eddd36c4b41bbfe17ad83a2b6114a98b08060acbdfc82a5ee02ee20c80 +size 29114 diff --git a/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/9cfd56352dca1cf4bc6096a369245a6a_img.jpg b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/9cfd56352dca1cf4bc6096a369245a6a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1416b07e2167267e2bd5f76befd6afbae8bfb4ee --- /dev/null +++ b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/9cfd56352dca1cf4bc6096a369245a6a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4480f347d91ecb801cdc2df54130dbaace5ad646f1477f068e21583c429431ae +size 4612 diff --git a/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f9786619d9266ddf6962b7631fad8834bd583a3 --- /dev/null +++ b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:17a48c732b82959a70a4744afdf56099b05c77a70dfcfaa935549c6ab678bec2 +size 4509 diff --git a/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/raw.md b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..263dc1edc4dddf70a9ccfd7de1a5beeeef509b7a --- /dev/null +++ b/marked/WG5/O-RAN.WG5.U.0-R003-v07.00/raw.md @@ -0,0 +1,177 @@ + + +# --- **O-RAN Work Group 5 (Open F1/W1/E1/X2/Xn Interfaces Working Group) NR U-plane profile** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|---------------------------------------------------------|---| +| Foreword..... | 4 | +| Modal verbs terminology ..... | 4 | +| 1 Scope..... | 5 | +| 2 References ..... | 5 | +| 3 Definitions of terms, symbols and abbreviations ..... | 6 | +| 3.1 Terms ..... | 6 | +| 3.2 Symbols..... | 6 | +| 3.2 Abbreviations ..... | 6 | +| 4 User plane function ..... | 6 | +| 4.1 Flow control ..... | 6 | +| 4.1.1 Elementary procedures ..... | 6 | +| 4.1.2 Elements for the NR user plane protocols..... | 7 | +| Annex (informative): Change History..... | 8 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG5 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# 1 Scope + +The present document provides profiles for the EN-DC and NG-RAN related NR U-plane procedures and functions to achieve interoperability among different vendors. The profiles specify the expected behavior of each node, e.g., message flow of each use case, definitions of IEs, etc. which is not specified in 3GPP specifications. The profile specification provided in this document does not violate 3GPP specifications. Overall architecture in EN-DC and NG-RAN is illustrated in TS 37.340 [1] and TS 38.300 [3], respectively. Note that the following two figures are created by O-RAN WG5. + +![Figure 1-1: EN-DC Overall Architecture diagram showing EPC and E-UTRAN components.](10418bccbde60b8b99bda8f0e4bc2664_img.jpg) + +The diagram illustrates the EN-DC (E-UTRA-NR Dual Connectivity) overall architecture. It is divided into two main sections: EPC (Evolved Packet Core) and E-UTRAN (E-UTRA Radio Access Network). In the EPC section, there are two MME/S-GW (Mobility Management Entity/Session Management Gateway) nodes. In the E-UTRAN section, there are two en-gNB (E-UTRA-NR Next-Generation NodeB) nodes and two eNB (E-UTRA NodeB) nodes. The connections are as follows: Each MME/S-GW in the EPC is connected to both en-gNB nodes in the E-UTRAN via S1-M and S1-U interfaces. The two en-gNB nodes are connected to each other via an X2-U interface. Each en-gNB node is connected to both eNB nodes via X2 interfaces. The two eNB nodes are connected to each other via an X2 interface. + +Figure 1-1: EN-DC Overall Architecture diagram showing EPC and E-UTRAN components. + +Figure 1-1: EN-DC Overall Architecture + +![Figure 1-2: NG-RAN Overall Architecture diagram showing 5GC and NG-RAN components.](856f0d4d6b96c90e511f7b8386e51811_img.jpg) + +The diagram illustrates the NG-RAN (Next-Generation Radio Access Network) overall architecture. It is divided into two main sections: 5GC (5G Core) and NG-RAN. In the 5GC section, there are two AMF/UPF (Access and Mobility Management Function/User Plane Function) nodes. In the NG-RAN section, there are two gNB (Next-Generation NodeB) nodes and two ng-eNB (Next-Generation E-UTRA NodeB) nodes. The connections are as follows: Each AMF/UPF node in the 5GC is connected to both gNB nodes in the NG-RAN via NG (Next-Generation) interfaces. The two gNB nodes are connected to each other via an Xn interface. Each gNB node is connected to both ng-eNB nodes via Xn interfaces. The two ng-eNB nodes are connected to each other via an Xn interface. + +Figure 1-2: NG-RAN Overall Architecture diagram showing 5GC and NG-RAN components. + +Figure 1-2: NG-RAN Overall Architecture + +# 2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. + +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 15. +- [1] 3GPP TS 37.340 V16.6.0: "Evolved Universal Terrestrial Radio Access (E-UTRA) and NR; Multi-connectivity; Stage 2". +- [2] 3GPP TS 38.425 V16.3.0: "NG-RAN; NR user plane protocol". +- [3] 3GPP TS 38.300 V16.6.0: "NR; NR and NG-RAN Overall Description; Stage 2" + +# --- 3 Definitions of terms, symbols and abbreviations + +## 3.1 Terms + +Definitions used in this specification refer to the ones defined in the referenced 3GPP specifications. + +## 3.2 Symbols + +Void + +## 3.2 Abbreviations + +Abbreviations defined in this document take precedence over the definition of the referenced 3GPP specifications. + +| | | +|------|-----------------------------| +| DDDS | DL DATA DELIVERY STATUS | +| AID | ASSISTANCE INFORMATION DATA | + +# --- 4 User plane function + +This section provides NR U-plane profile to achieve interoperability. In this version of the profile, RLC-AM and RLC-UM are supported. In this version of the profile, the following procedure is defined. + +- Flow control + +## 4.1 Flow control + +### 4.1.1 Elementary procedures + +#### 4.1.1.1 Node behaviour of the corresponding node + +- When the corresponding node indicates Radio Link Outage over NR-U, the corresponding node shall not interpret the Radio Link Outage indication as a trigger to discard any remaining packets for RLC-AM and RLC-UM and shall not discard the packets unless receiving indication from the higher layer, e.g. RLC entity re-establishment/release, or buffer discard indication from the node hosting the NR PDCP entity. +- Unless a situation of overload at the corresponding node is encountered, the corresponding node may send DDDS in the following cases in addition to the cases TS 38.425 [2] defines: + +- Lost packet detection +- Radio link outage +- Stop scheduling for the data bearer + +### 4.1.2 Elements for the NR user plane protocols + +#### 4.1.2.1 General + +- For the optional fields of DDDS, if the corresponding value is not available yet (e.g. no valid corresponding PDCP SN to be reported as the corresponding node hasn't yet transmitted any NR PDCP PDU to the lower layer), the corresponding node shall not include the corresponding IEs (including the corresponding indication for presence) in the DDDS. Once the value comes to be valid or updated, the corresponding node shall include them at least in the next DDDS. + +NOTE: For Lost Packet Report fields, if the value is continuously reported in the consecutive DDDS, the node hosting the NR PDCP entity cannot identify whether the reported lost NR-U Sequence Number is for before or after the wrap around. How to prevent this is up to implementation. + +#### 4.1.2.2 Report polling + +- The node hosting the NR PDCP entity shall use this IE to trigger the corresponding node to send DDDS when the Report Polling Flag set to 1. +- The corresponding node shall send DDDS when the Report Polling Flag set to 1, unless a situation of overload at the corresponding node is encountered. + +#### 4.1.2.3 Buffer discard Indication + +- The corresponding node shall support both DL Discard Blocks and DL Flush for the buffer discard indication. + +#### 4.1.2.4 User data existence flag + +- In case of split bearer, when the corresponding node does not support the IE, e.g. for the corresponding node compliant with the former version of 3GPP specification, the node hosting the NR PDCP entity shall send the actual user data to notify the existence of user data. + +#### 4.1.2.5 Assistance Information Report Polling Flag + +- The node hosting the NR PDCP entity shall use this IE to trigger the corresponding node sending AID whenever it needs. + +NOTE: Whether the corresponding node sends AID by itself is up to implementation. + +#### 4.1.2.6 Radio quality assistance information + +- It is configured via M-plane which assistance information to be included in AID. +- For the information configured to be reported and supported by the corresponding node: + - if corresponding value is not available yet (e.g. no valid Power Headroom Report to be reported as the corresponding node hasn't yet received any Power Headroom Report from the UE): + - ✧ the corresponding node shall not include the corresponding information in the reporting AID. + - else: + +- ✧ the corresponding node shall include the latest value as the corresponding information in the consecutive AID, even when there is no update from the previous reported AID. +- ✧ when Power Headroom Report is configured to be reported and multiple data bearers are configured to one UE, the corresponding node shall include Power Headroom Report information in all the reporting AID. +- For the information configured not to be reported or not supported by the corresponding node, the corresponding node shall not include the corresponding information in the AID. + +#### 4.1.2.7 DL report NR PDCP PDU SN + +- The node hosting the NR PDCP entity may use this IE to trigger the corresponding node to send DDDS when the NR PDCP PDU with this sequence number has been successfully delivered. +- The corresponding node, if supported, shall send DDDS when the NR PDCP PDU with the indicated DL report NR PDCP PDU SN has been successfully delivered, unless a situation of overload at the corresponding node is encountered. The DDDS sent as a response to a specific DL report NR PDCP PDU SN shall be sent only when all PDCP PDU SNs up to this DL report NR PDCP PDU have been successfully delivered in-sequence. + +# Annex (informative): Change History + +| Date | Revision | Author | Description | +|------------|----------|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2019.04.08 | 1.00 | H. Ou<br>(NTT DOCOMO) | Final version 1.00 | +| 2019.09.19 | 2.00 | H. Ou<br>(NTT DOCOMO) | This version of the specification contains updates for the clarification about the use of NR-U protocol. | +| 2020.06.19 | 3.00 | K. Teshima<br>(NTT DOCOMO) | This version of the specification contains general updates. In addition, minor editorial corrections were done in Annex ZZZ. | +| 2021.03.05 | 4.00 | K. Teshima<br>(NTT DOCOMO) | The version of 3GPP specs referred in this specification is updated. | +| 2021.11.17 | 5.00 | K. Teshima<br>(NTT DOCOMO) | The version of 3GPP specs referred in this specification is updated to Rel-16. | +| 2023.11.16 | 6.00 | K. Teshima<br>(NTT DOCOMO) | This version of the specification contains following updates: <ul style="list-style-type: none"> <li>● RLC UM is added to the supported Mode of RLC in this profile.</li> <li>● New profile of DL report NR PDCP PDU SN is specified.</li> </ul> | +| 2024.03.07 | 6.00.01 | K. Saito<br>(NTT DOCOMO) | Following changes are included. <ul style="list-style-type: none"> <li>● Technical changes agreed in CR DCM-00-88</li> <li>● Editorial error in the chapter of 4.1.1.1 (From “encounterd” to “encountered”)</li> <li>● Format changes (not technical changes) to follow the latest O-RAN document template</li> </ul> | +| 2024.03.14 | 6.00.02 | K.Saito<br>(NTT DOCOMO) | Editorial error in the chapter of 4.1.1.1 (From “difines” to “defines”) was fixed. | +| 2024.03.21 | 6.00.03 | K.Saito<br>(NTT DOCOMO) | This version has the same content as the version 06.00.02 with the difference that this version has no comments, the track changes information is removed and the revision history is added. | \ No newline at end of file diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/228755dceb6360f24aeac70d3607b395_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/228755dceb6360f24aeac70d3607b395_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b3ebebbd0f9979a0ce14db92d017714150fb442a --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/228755dceb6360f24aeac70d3607b395_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9b21ee09fb698a60937c0b9ab3a6ccfcb9adef9cbc63cf05572a97da1161d538 +size 89459 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/235b168d85e3cac36c923ec0dad7e754_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/235b168d85e3cac36c923ec0dad7e754_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0aec919693e3229eee2f7503f8d545230271b8c0 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/235b168d85e3cac36c923ec0dad7e754_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5e0dd86261cba01906dd1bc838476edc234728943c2df48ea259ce02f9f03cb8 +size 87550 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/4531e9334539f54947a26f50080ba4d2_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/4531e9334539f54947a26f50080ba4d2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d56247966fcd8c91043c7bbe92cd89e09fbcc14a --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/4531e9334539f54947a26f50080ba4d2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:de0443df5ee718f3a8b001e6bf53dd69a2f7f6d81e9b78afba38e40a377d9ef9 +size 223634 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..27225d0aa300adaafdd4117dedc67749d0a1a206 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48cf233b970eeaabdd503be04bfc1c953c2305a08074046287524dfb5e1dcd7c +size 4522 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/940f3525f840ee29f4790e4ee7d093d8_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/940f3525f840ee29f4790e4ee7d093d8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d02acdb5c63ca3d4fd3318c9c819ac743a57fc4a --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/940f3525f840ee29f4790e4ee7d093d8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:42c86c9a38145f623f53b33dcc9b6ec230ee96f2752f6066b4fcc3c02cb3f76e +size 70330 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/b59a936b7953a11cffd55389457451b4_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/b59a936b7953a11cffd55389457451b4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e5b8e84c7a76b7e73900b777c6c1cbdef576e034 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/b59a936b7953a11cffd55389457451b4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5f2083557bf5c8d39806f124d2443e0865e071648ad47eacc77a9e2ff7501ae5 +size 118644 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d0a511102357780ee8e2f8b7e57aa2b8_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d0a511102357780ee8e2f8b7e57aa2b8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aad6bb9d8cac742cf4db0c84d58b270af8086a99 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d0a511102357780ee8e2f8b7e57aa2b8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4ffc91dcedf48f843c0b0f091c2132992f52f89c150253fe3ea386f7ad8d5380 +size 4523 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d1598874f60052d6f583f603aa73411b_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d1598874f60052d6f583f603aa73411b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d312583dd380e922cb52322eaa8e7ff713361aaf --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d1598874f60052d6f583f603aa73411b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2936ebbb3510ea824026823e6c33da8d9c18d2e6aeea533b07ff07d0e55ca6af +size 253619 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2607b0eef27677fb38e9fdbba214fde5d86a7f72 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9e383e92647a2356488a833110e26ad296a5dd136dd01f365e78a67474a8258 +size 4548 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/db3b5905971d996161f8f44d9e6ff64f_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/db3b5905971d996161f8f44d9e6ff64f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..037b7f6e476e194344a98c984bc0b29f0bd2c8dd --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/db3b5905971d996161f8f44d9e6ff64f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c1557b85e692b1ec6b94e9c7b25f6d4b06b061f467897a0a1efbd7253e5a4046 +size 4585 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/raw.md b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..60a0a4c9e1e9384043388316d055151debe86a36 --- /dev/null +++ b/marked/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00/raw.md @@ -0,0 +1,857 @@ + + +# --- **O-RAN Working Group 6** + +# **Application Life Cycle Management (LCM) for Deployment Technical Recommendation** + +Copyright © 2023 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +# Contents + +| | | +|-----------------------------------------------------------------------|-------------------------------------| +| List of figures ..... | 3 | +| List of tables ..... | 3 | +| Foreword..... | 4 | +| Modal verbs terminology ..... | 4 | +| Executive summary <optional>..... | 4 | +| Introduction <optional>..... | 4 | +| 1 Scope ..... | 5 | +| 2 References ..... | 5 | +| 2.1 Informative references ..... | 5 | +| 3 Definition of terms, symbols and abbreviations..... | 6 | +| 3.1 Terms ..... | 6 | +| 3.2 Symbols ..... | 6 | +| 3.3 Abbreviations..... | 7 | +| 4 Background ..... | 7 | +| 4.1 Introduction..... | 7 | +| 4.2 App Package ..... | 8 | +| 4.2.1 App Package Concepts..... | 8 | +| 4.1.2 App Package Security ..... | 9 | +| 4.1.3 App Package DeploymentDescriptor ..... | 10 | +| 4.1.4 CloudNativeDescriptorFile and ExecutableImage ..... | 11 | +| 5 Use Cases ..... | 11 | +| 5.1 Deployment Flow For ASD And Cloud Native Artifacts Use Case ..... | 11 | +| 5.1.1 Introduction ..... | 11 | +| 5.1.2 UML Sequence Diagram..... | 12 | +| 5.1.3 Sequence Table ..... | 14 | +| 5.1.4 Recommended Requirements..... | <b>Error! Bookmark not defined.</b> | +| 6 Information Requirements for K8s-Aware Solution ..... | 22 | +| 6.1 DeploymentDescriptor..... | 22 | +| 6.1.1 Metadata ..... | 29 | +| 6.1.2 Security ..... | 29 | +| 6.1.3 Resource Requirements..... | 29 | +| 6.1.4 DeploymentItems ..... | 29 | +| 6.1.5 Other..... | 29 | +| 6.2 DeploymentItem ..... | 29 | +| 6.2.1 Deployment Sequencing ..... | 29 | +| 6.2.2 Lifecycle Requirements..... | 29 | +| 7 Information Requirements for ETSI-based Solution..... | 30 | +| 7.1 DeploymentDescriptor..... | 30 | +| 7.2 DeploymentItems..... | 30 | +| 8 Formatting Recommendations ..... | 30 | +| 8.1 CSAR..... | 30 | +| 8.2 SOL004..... | 30 | +| A.1 <here is a sample Annex sub-heading> ..... | <b>Error! Bookmark not defined.</b> | +| History ..... | 33 | + +# List of figures + +| | | +|----------------------------------------------------------------------------------|----| +| Figure 4.1-1 Common Application Life Cycle Management for ASD ..... | 8 | +| Figure 4.2.2-1 Package Security Approaches ..... | 10 | +| Figure 4.2.3-1 Deployment Descriptor Model ..... | 10 | +| Figure 5.1.2-1 Deployment Flow for ASD and Cloud Native Artifacts Use Case ..... | 14 | +| Figure 5.2.2-1 Flow of NF Deployment instantiation with VNFD ..... | 19 | +| Figure 6.1.1-1 DeploymentDescriptor with ASD representation ..... | 23 | + +# List of tables + +| | | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----| +| Table 1.1-1 Revision per Topic ..... | 5 | +| Table 3.3-1 Abbreviations & Acronyms ..... | 7 | +| Table 5.1.3-1 Deployment Flow for ASD and Cloud Native Artifacts Use Case ..... | 14 | +| Table 5.1.4-1 Recommended Requirements for Deployment flow for ASD ..... | 17 | +| Table 5.2.3-1 Flow of NF Deployment instantiation with VNFD ..... | 19 | +| Table 5.2.4-1: Potential requirements related to VNFD for application deployment ..... | 22 | +| Table 6.1.2-1 ASD Information Model ..... | 24 | +| Note 1: Applies only for ExtCpd representing secondary network interfaces in a POD. Note 2: Several ExtCpd may refer to same additional network interface requirements. .... | 25 | +| Table – Revision History ..... | 32 | +| Table - History of the Document ..... | 33 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +--- + +## Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Executive summary + +This is a Technical Recommendation from the WG6 Cloudification & Orchestration working group that documents the deployment flow use case, application package, package artifacts, and life cycle management. + +The content of this TR itself is not normative. However, it will recommend possible requirements that are recommended to be incorporated into the Orchestration Use Case and Requirements document. Furthermore, the various sections of this document such as use case flows, application package, and package artifacts related to provisioning will be ported into their appropriate normative documents. + +Because of the scope and nature of this document, there are a number of major sections in this document that will be tracked separately as they become mature. + +--- + +# Introduction + +Orchestration is the process of onboarding packages that have applications so that application artifacts can be made available during LCM. This is a Technical Recommendation from the WG6 Cloudification & Orchestration working group that documents the deployment flow use case, application package and life cycle management. The Deployment flow in this document shows detailed flows of what happens to accomplish deployment of applications. + +The content of this TR itself is not normative. But, it will recommend possible requirements that are recommended to be incorporated into the Orchestration Use Case and Requirements document. The Deployment flow Use case is recommended to be integrated into the Orchestration Use Case document. + +Because of the scope and nature of this document, there are a number of major sections in this document that will be tracked separately as they become mature. The document contains content for K8s aware and ETSI NFV aware solutions. + +The recommendation section of this document provides recommendations of where the content should be incorporated into what normative specifications. + +# 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document specifies a Technical Recommendation from the WG6 Cloudification & Orchestration working group that documents the deployment flow use case, application package and life cycle management. + +This document covers the orchestration & cloudification aspects for the Application Package model. The model is developed in the OAM Specification [1]. + +## 1.1 Revision History per Topic + +**Table 1.1-1 Revision per Topic** + +| TOPIC | REVISION STATUS | +|-----------------------------------------------------------------------------------------|--------------------------------------------------| +| Application Package Concepts & Security | Clause 4.2 / Reviewed / March 2023 Release Train | +| Deployment Flow for ASD and Cloud Native Artifacts Use Case | Clause 5.1 / Reviewed / March 2023 Release Train | +| Deployment Flow for VNFD Use Case | Clause 5.2 / Reviewed / March 2023 Release Train | +| Potential & Recommended Requirements | Clause 5.2 / Reviewed / March 2023 Release Train | +| Deployment Descriptor with ASD (Information Requirements for K8s-aware solution) | Clause 6.1 / Reviewed / March 2023 Release Train | +| Deployment Descriptor with VM (Information Requirements for ETSI VNF VM-aware solution) | Clause 6.x / | + +# 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [1] O-RAN.WG10.OAM-Architecture: “O-RAN Operations and Maintenance Architecture”. +- [2] Kubernetes label key-value-nomenclature <https://kubernetes.io/docs/concepts/overview/working-with-objects/labels/> +- [3] Kubernetes node features <https://kubernetes-sigs.github.io/node-feature-discovery/v0.9/get-started/features.html#table-of-contents> +- [4] O-RAN WG10 App Package Specification +- [5] O-RAN Cloudification & Orchestration Use Case and Requirements +- [6] ETSI GS NFV-SOL 004 (V4.3.1): "Network Functions Virtualisation (NFV) Release 4; Protocols and Data Models; VNF Package and PNFD Archive specification". +- [7] ETSI GS NFV-IFA 011 (V4.3.1): "Network Functions Virtualisation (NFV) Release 4; Management and Orchestration; VNF Descriptor and Packaging Specification". +- [8] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE (V03.00): "O-RAN Working Group 6: O2dms Interface Specification: Profile based on ETSI NFV Protocol and Data Models". +- [9] O-RAN WG6 O2DMS INTERFACE K8S PROFILE (v02.00): “O-RAN Working Group 6 O2dms Interface Specification: Kubernetes Native API Profile for Containerized NFs”. +- [10] O-RAN WG6 O2IMS INTERFACE (v03.00):” O-RAN Working Group 6 O2ims Interface Specification”. +- [11] ETSI GS NFV-SEC 021 (V2.6.1): “Network Functions Virtualisation (NFV) Release 2; Security; VNF Package Security Specification” +- [12] O-RAN.WG11.Security-Requirements-Specification.O (R003-v05.00.01): “O-RAN Working Group 11 Security Requirements Specifications” +- [13] O-RAN.WG6.ASD Specification “O-RAN Working Group 6 ASD Specification” + +# --- 3 Definition of terms, symbols, and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +**DeploymentDescriptor:** a template validated by the Solution Provider describing the deployment options for the application that includes one or more **DeploymentItems**. + +**DeploymentItem:** a template that describes the requirements for the deployment of *a component of* the application on the O-Cloud. + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations & Acronyms + +For the purposes of the present document, the abbreviations apply: + +**Table 3.3-1 Abbreviations & Acronyms** + +| Abbreviation & Acronyms | Definition | +|-------------------------|-------------------------------------------------| +| AI / ML | Artificial Intelligence & Machine Learning | +| ASD | Application Service Descriptor | +| CSAR | Cloud Service Archive | +| DMS | Deployment Management Services | +| ETSI | European Telecommunications Standards Institute | +| IMS | Infrastructure Management Services | +| K8s | Kubernetes | +| LCM | Life Cycle Management | +| OA&M | Operations, Administration & Management | +| O-RAN | Open Radio Access Network | +| SMO | Service Management & Orchestration | +| VNFD | VNF Descriptor | + +# 4 Background + +## 4.1 Introduction + +This section describes the Common Application Life Cycle Management of applications that are developed by a Solution Provider and delivered to a Service Provider or Network Operator for deployment in an O-Cloud. Once the Solution Provider delivers the NF deployment, it is validated in a test environment prior to giving to operations to deploy. The description of the delivery of the NF deployments to the Service Provider as part of LCM is detailed in the OAM architecture document. The framework for Lifecycle Management is defined in the OAM Architecture document [1]. The O-RAN Cloudification & Orchestration aspects described here complements the concepts in the OAM Architecture specification. The following diagram in **Error! Reference source not found.** is an example that applies to the ASD solution for didactic purposes. + +![Figure 4.1-1 Common Application Life Cycle Management for ASD. The diagram illustrates a four-step process: 1. Deliver (CSAR App package), 2. Onboarding (SMO, Cloud-native deployment tool, Catalog), 3. Certification Process (Artifact repository), and 4. Deploy (O-Cloud, NF Deployment).](235b168d85e3cac36c923ec0dad7e754_img.jpg) + +The diagram illustrates the Common Application Life Cycle Management for ASD, showing a four-step process: + +- Step 1: Deliver**: A CSAR (App package) is delivered, containing Deployment Descriptors, Other Descriptors, and Artifacts. +- Step 2: Onboarding**: The SMO (Service Management Orchestrator) performs onboarding using a Cloud-native deployment tool (e.g., Helm) and a Catalog. +- Step 3: Certification Process**: The package undergoes a certification process, resulting in an Artifact repository (aka run-time library). +- Step 4: Deploy**: The package is deployed to the O-Cloud (Open Cloud) via NF Deployment, which then feeds into the Artifact repository. + +Figure 4.1-1 Common Application Life Cycle Management for ASD. The diagram illustrates a four-step process: 1. Deliver (CSAR App package), 2. Onboarding (SMO, Cloud-native deployment tool, Catalog), 3. Certification Process (Artifact repository), and 4. Deploy (O-Cloud, NF Deployment). + +**Figure 4.1-1 Common Application Life Cycle Management for ASD** + +The above diagram depicts some of the key steps in basic application package orchestration: + +- Step 1, **DELIVER**: a solution provider (vendor) delivers an application package (app package) which may include a variety of artifacts. These artifacts may include application descriptors, model descriptors, informational artifacts, cloud native artifacts, metadata, and dictionaries. +- Step 2, **ONBOARDING**: Onboarding involves the ingestion, verification, and unpacking of the package and storage into a catalog. The SMO performs these onboarding activities and may use cloud-native onboarding tools for that purpose. During this process, an AI/ML model can be trained. + - o Security Package Validation – During onboarding, the security validation of the package or package artifact(s) is performed. See the OAM Architecture document [1] clause 4.1.3, and clause 4.1.4. +- Step 3, **CERTIFICATION PROCESS**: After onboarding, the package undergoes a certification process from the catalog in the SMO. Afterwards, it is published to an artifact repository (aka the run-time library). Certification of the package may include the following: security validation of artifacts, metadata verification, artifact verification against indicated metadata locations. See the OAM Architecture document [1]. + - o Note: The package cannot be certified until training is finished. If the AI/ML training cannot complete, the package is not certified. + - o Note: The package cannot be certified until security validation of the package is completed. + - o Note: For some operators, the package may go through part of the certification process before onboarding (Step 1 and Step 2). +- Step 4, **DEPLOY**: In deployment, The deployment tool is given a reference to the image repository entry from which the image can be pulled. Inventory is updated. + +## 4.2 App Package + +### 4.2.1 App Package Concepts + +The package concepts are motivated from the ETSI GS NFV-SOL 004 [2] standards which describe the directory structure and required files for a package. + +The Application Package contains: + +Manifest file – The manifest file describes the location and types of files in the package. + +Metadata – The metadata contains reference information related to the package itself. It is information about the information in the package, hence it is called metadata. + +Other artifacts – The package can also contain other artifacts as well such as informational artifacts. + +Note: The OAM Architecture specification [1] does not cover details about the application package. + +### 4.2.2 App Package Security + +An important aspect of managing application packages of CNFs, VNFs, rApps, and xApps as it relates to O-RAN Cloudification & Orchestration are the security aspects. + +The [WG11 Security Requirements specification \[12\]](#) covers security requirements and controls related to package security. These requirements follow ETSI GS NFV-SEC 021 [11], ETSI GS NFV-IFA011 [3] (stage 2) and ETSI GS NFV-SOL 004 [2] Clause 5.1 (stage 3) which describes two options for package security: + +**Option 1 Per Artifact:** The VNF package shall contain a Digest (a.k.a. hash) for each of the components of the VNF package. The table of hashes is included in the *manifest file*, which is signed with the VNF provider private key. In addition, the VNF provider shall include a signing certificate that includes the VNF provider public key, following a pre-defined naming convention and located either at the root of the archive or in a predefined location (e.g., directory). The certificate may also be included in the signature container if the signature format allows that. For example, the CMS format allows to include the certificate in the same container as the signature. + +All package artifacts shall be individually signed by the VNF provider as per ETSI GS NFV-SOL 004 [2] Clause 5.4 (stage 3) and the WG11 Security Requirements specification [12]. + +**Option 2 Per CSAR Package:** The complete CSAR file shall be digitally signed with the VNF provider private key. The VNF provider delivers one zip file consisting of the CSAR file, a signature file and a certificate file that includes the VNF provider public key. Only one signature of the CSAR file shall be present. The certificate may also be included in the signature container if the signature format allows that. The manifest shall be signed in both option 1 and option 2. Only one signature of the manifest shall be present. + +![Diagram titled 'PACKAGE SECURITY APPROACHES' showing two options for package security. Option 1, 'Per Artifact Security', shows a CSAR (App package) containing ASD, App Desc, and ML model Desc, with a separate Manifest file containing a table of hashes. Option 2, 'Package Security', shows a CSAR (App package) containing ASD, App Desc, and ML model Desc, with a separate signature file and certificate file.](b59a936b7953a11cffd55389457451b4_img.jpg) + +Diagram titled 'PACKAGE SECURITY APPROACHES' showing two options for package security. Option 1, 'Per Artifact Security', shows a CSAR (App package) containing ASD, App Desc, and ML model Desc, with a separate Manifest file containing a table of hashes. Option 2, 'Package Security', shows a CSAR (App package) containing ASD, App Desc, and ML model Desc, with a separate signature file and certificate file. + +Figure 4.2.2-1 Package Security Approaches + +### 4.2.3 App Package DeploymentDescriptor + +This section describes the Application Package (App Package) as it relates to O-RAN Cloudification & Orchestration. The OAM Architecture document (see reference [1]) details the Application Package model which details the high-level composition of the Application Package (AppPackage). This is shown in figure 2. The part of that model that is pertinent to O-RAN cloudification & orchestration that is within scope of the [Work Item Technical Report] is demarcated with a blue box in figure 2. + +This section also describes the Application Service Descriptor (ASD) and the VNF Descriptor (VNFD) in the application package. These two things serve the same function in their respective profiles, and these terms are used interchangeably through the rest of the document. The ASD is a simplified deployment descriptor compared to the VNFD for CNFs, xApps and rApps to leverage enhancements in orchestrators. + +![Figure 4.2.3-1 Deployment Descriptor Model diagram showing the relationships between AppPackage, DeploymentDescriptor, DeploymentItem, ComponentDescriptor, ManagementDescriptor, and various descriptors like CloudNativeDescriptorFile, ExecutableImage, RTEDescriptor, SecurityDescriptor, AlarmDictionary, ConfigurationModel, AccountingDictionary, and PerformanceDictionary. A blue box highlights the ASD/VNFD scope.](940f3525f840ee29f4790e4ee7d093d8_img.jpg) + +The diagram illustrates the Deployment Descriptor Model. At the top is the **AppPackage** (blue box). It has a **Has** relationship with **DeploymentDescriptor** (blue box) and a **May Have** relationship with **MLModelDescriptor** (pink box). **DeploymentDescriptor** has a **Has** relationship with **DeploymentItem** (blue box). **DeploymentItem** has a **May Have** relationship with **ComponentDescriptor** (yellow box) and a **Has** relationship with **CloudNativeDescriptorFile** (green box). **ComponentDescriptor** has a **May Have** relationship with **ManagementDescriptor** (yellow box) and a **May Have** relationship with **RTEDescriptor** (yellow box). **ManagementDescriptor** has a **Has** relationship with **SecurityDescriptor** (yellow box), **AlarmDictionary** (yellow box), **ConfigurationModel** (yellow box), **AccountingDictionary** (yellow box), and **PerformanceDictionary** (yellow box). **CloudNativeDescriptorFile** has a **May Have** relationship with **ExecutableImage** (green box). A blue box highlights the **ASD/VNFD** scope, which includes **DeploymentDescriptor**, **DeploymentItem**, **CloudNativeDescriptorFile**, and **ExecutableImage**. The text "O-RAN cloudification & orchestration Scope" is written below the blue box. + +Figure 4.2.3-1 Deployment Descriptor Model diagram showing the relationships between AppPackage, DeploymentDescriptor, DeploymentItem, ComponentDescriptor, ManagementDescriptor, and various descriptors like CloudNativeDescriptorFile, ExecutableImage, RTEDescriptor, SecurityDescriptor, AlarmDictionary, ConfigurationModel, AccountingDictionary, and PerformanceDictionary. A blue box highlights the ASD/VNFD scope. + +Figure 4.2.3-1 Deployment Descriptor Model + +In figure 2, the part of the model highlighted with the blue box, shows that the **DeploymentDescriptor** is contained within an **AppPackage**. The **DeploymentDescriptor** has a composition relationship to **DeploymentItem(s)**. The **DeploymentItem(s)** has a composition (containment) relationship to one cloud native descriptor files. The **DeploymentItem** has an association relationship with the **ExecutableImage(s)** which has a cardinality of zero to many. + +In figure 2, the part of the model highlighted with the blue box, ties back to the application package model management descriptor which is described in more detail in this TR. Note: future versions of this document will further describe this part of the model (in the blue box). + +This TR suggests that the **DeploymentDescriptor** and **DeploymentItem(s)** be contained within one artifact in the package as an **Application Service Descriptor (ASD)** or **VNF Descriptor (VNFD)**. The **DeploymentItem** is part of the ASD. However, it is possible that the **DeploymentDescriptor** and **DeploymentItem(s)** could be in separate artifact. + +There will be metadata pertaining to the cloud native descriptor file. The metadata will include the checksum/hash, and type of file (helm, K8s manifest, SOL doc). From a workflow perspective, it uses the metadata to determine the appropriate action to take. The ASD allows the SMO to determine the resource requirements based on variables of the cloud native descriptor file. The deployment requirements can be derived for the executable image from the deployment item and the cloud native descriptor file. + +The OAM architecture document and Information Model specification in reference [1] in the Lifecycle Management section describes the full model and the components show in more detail. + +### 4.2.4 CloudNativeDescriptorFile and ExecutableImage + +# --- 5 Use Cases + +## 5.1 Deployment Flow for ASD And Cloud Native Artifacts Use Case + +### 5.1.1 Introduction + +This describes a use case and flow to deploy an application (such as a NF deployment) into the O-Cloud. The deployment uses a deployment tool that is appropriate for the artifactType in the DeploymentItem. + +This use case is for an application deployment on a K8s Cluster with an ASD. + +NOTE 2: The use case flow illustrates interactions among entities within the SMO and between the SMO and the O-Cloud. + +### 5.1.2 UML Sequence Diagram + +![](d1598874f60052d6f583f603aa73411b_img.jpg) + +**Personnel** + +Cloud Operator + +**Service Management & Orchestration Framework** + +Orchestrator + +Deployment Tools + +**O-Cloud Platform** + +DMS + +**NOTE:** Steps detailing SMO internal interactions is for illustrative purposes, and its specification is out of the scope of the present document. See also note 1 in clause 5.1.1. + +**PRECONDITIONS:** +App Package for NF Deployment is onboarded and cataloged +SMO has connectivity to O-Cloud +O-Cloud has registered all its DMSs from different sites with the SMO + +**Deployment Flow Use Case** + +**TRIGGER CONDITION:** +(1) Operator Initiates Deployment + +**Deployment requirements** + +1 Deployment lifeCycle Parameters + +2 Extract xNF Constraints from deployment descriptor (e.g., ASD) + +**alt [Collect Input & Parameterizations (Optional)]** + +Collects resource requirements for that NF deployment, to be used for homing decision + +3 Cloud Artifacts & lifeCycle Parameters + +4 K8s Manifest file result from processing the CloudNativeDescriptor Files and then collecting the resource requirements from them + +5 Update resource requirements + +6 Calculate resource requirements + +**alt [Homing Operation (Cluster ID not provided)]** + +**Homing Operation** + +7 Homing Decision selects one target K8s cluster matching xNF deployment resource requirements and constraints + +**[Homing Operation (Cluster ID already provided)]** + +8 Check inventory that Cluster ID has free resources for placement. Check cluster fulfils constraints from DeploymentDescriptor. + +**[Homing Operation Cluster ID provided but it does not have free resources]** + +9 No Free Resources or constraints not fulfilled + +**Cluster does not have free resources Use Case Ends** + +**opt [Cluster has a special configuration needed (Optional)]** + +The cluster has a special configuration required, possibly an inter-cluster network + +10 A special cluster configuration need has been identified + +11 Goes to FOCOM/IMS to configure the cluster + +12 Cluster ID and parameterized cloud artifacts + +13 Cluster ID, lifeCycle Parameters, Cloud Artifacts + +14 Deployment + +**End Deployment Flow Use Case** + +Cloud Operator + +Orchestrator + +Deployment Tools + +DMS + +**Figure 5.1.2-1 Deployment Flow for ASD and Cloud Native Artifacts Use Case** + +### 5.1.3 Sequence Table + +**Table 5.1.3-1 Deployment Flow for ASD and Cloud Native Artifacts Use Case** + +| USE CASE STAGE | EVOLUTION / SPECIFICATION | <<Uses>><br>Related Use | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Use Case Title | Deployment Flow using ASD and Cloud Native Artifacts Use Case | | +| Goal | <p>The SMO uses the data available in the respective Deployment Descriptor to extract the specific xNF constraints (e.g., additional connectivity requirements, specific infrastructure capabilities needed, the specific input values provided in the lifecycle Parameters, etc.).</p> <p>The SMO makes the homing decision (chooses a Kubernetes cluster) that matches the xNFs deployment requirements and parameterizes the cloud artifacts according to the received input (such as K8s resource descriptions, ASD, and other relevant data available for respective deployment).</p> | | +| Actors and Roles | <p>Cloud Operator – An operator of the Cloud.</p> <p>SMO: Orchestrator – One of the components in the SMO that coordinates orchestration.</p> <p>SMO: Deployment Tool – One of the components in the SMO that manages the cloud native deployment.</p> <p>O-Cloud DMS – The O-Cloud Deployment Management Services.</p> | | +| Assumptions | <p>Deployment tool – It is assumed that the SMO has the proper deployment tool that corresponds to the artifactType in the DeploymentItem. For example, helm.</p> <p>Deployment descriptors – This consists of a DeploymentDescriptor and one to many CloudNativeDescriptorFiles.</p> | | +| Preconditions | <p>Onboarded & Cataloged – The App Package for NF Deployment is onboarded and cataloged.</p> <p>Connectivity – SMO has connectivity to O-Cloud.</p> <p>O-Cloud Operational – O-Cloud has registered its DMS with the SMO.</p> | | +| Begins when | This use case begins when the Cloud Operator initiates the creation of a NF Deployment. | | +| Step 1 (M) | <p>The Cloud operator initiates a deployment operation which consists of a set of a DeploymentItem, which supports complex applications that require multiple artifacts (like Helm charts) to be installed in a particular order.</p> <p>Each deploymentOrder is from a list of DeploymentItem constructs. Each DeploymentItem has lifeCycleParameters that show how the input parameters for that deployment are mapped into their respective CloudNativeDescriptorFiles.</p> | | +| Step 2 (M) | EXTRACTS xNF CONSTRAINTS | | + +| | | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| | The orchestrator extracts xNF constraints from the NF deployment descriptor, in this case the ASD. | | +| Step 3 (ALT, OPT) | <p>COLLECT INPUT & PARAMETERIZATIONS(Optional)</p> <p>The purpose of the collect input & parameterizations step is to use input received from the Cloud operator for this deployment and map it into the CloudNativeDescriptorFiles according to mapping provided by the lifeCycleParameters and determine a K8s Resource Descriptor.</p> <p>The deployment tool receives and processes the cloud artifacts and lifeCycleParameters native to the cloud artifact. The artifactType defines the type of artifacts within the DeploymentItem and what will be native to those artifacts.</p> <p>The lifeCycleParameters are the list of parameters that can be overridden at deployment time (e.g., the list of parameters in the values.yaml).</p> | | +| Step 4 (ALT, OPT) | <p>OUTPUT K8s MANIFEST FILES</p> <p>The deployment tool returns the K8s manifest files and collects the resources requirements.</p> | | +| Step 5 (ALT, OPT) | <p>PROCESS K8s MANIFEST FILE</p> <p>K8s Manifest is processed to update the xNF constraints.</p> | | +| Step 6 (M) | <p>CALCULATE RESOURCE REQUIREMENTS</p> <p>The orchestrator calculates the resource requirements.</p> | | +| Step 7 (ALT) | <p>HOMING DECISION (CLUSTER ID IS NOT PROVIDED)</p> <p>The orchestrator performs the homing step.</p> <p>The homing decision uses the aggregated resource requirements, constraints fetched from the DeploymentDescriptor (e.g., ASD) and data available locally for the SMO to process the decision. Note: data may be anything that the SMO knows out of the scope of the ASD and K8s resource descriptor.</p> <p>The orchestrator makes a homing decision that matches the NF deployment requirements. It identifies a K8s cluster type or instance to deploy upon. The Homing operation selects the DMS that will be used. If an operator has multiple clouds (each one with multiple DMSes), the orchestrator will identify which cloud and DMS that are used.</p> | | +| Step 8 (ALT) | <p>HOMING DECISION (CLUSTER ID IS AVAILABLE)</p> <p>The orchestrator checks that the inventory has the referred cluster with free resources for placement based on the aggregated resource requirements. Also, it checks that the cluster fulfils the constraints from the DeploymentDescriptor.</p> | | +| Step 9 (ALT) | <p>POSSIBLE ALTERNATIVE FLOW: HOMING DECISION (CLUSTER ID PROVIDED BUT NO FREE RESOURCES OR CONSTRAINTS NOT FULFILED)</p> <p>The cluster designated by the Cluster ID doesn't have the free resources needed for the application deployment.</p> <p>A failure notification is sent.</p> <p>The orchestrator continues to seek a suitable cluster, going back to step 5.</p> | | + +| | | | +|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| | Note: The repetition, defaults for retries of the homing decision are implementation specific. | | +| Step 10 (ALT) | <p>ALT FLOW: ADDITIONAL CLUSTER PROVISIONING IS NEEDED</p> <p>This alt flow is used if additional cluster provisioning is required.</p> <p>For example, it might be the case that the deployment requires an inter-cluster network. The deployment may span more than one cluster. In this case, the orchestrator may have to go back to FOCOM/IMS because the cluster networks would need to be provisioned in the IMS.</p> | | +| Step 11 (ALT) | <p>ALT FLOW: CONFIGURE THE CLUSTER</p> <p>The orchestrator will instruct FOCOM/IMS to configure the cluster.</p> | | +| Step 12 (M) | <p>DEPLOYMENT REQUEST</p> <p>The deployment is performed with the cluster ID, and the required cloud artifacts (e.g., K8s manifest).</p> | | +| Step 13 (M) | <p>DEPLOYMENT REQUEST</p> <p>The orchestrator (SMO) requests for the deployment tools (SMO) for the deployment operation with the Cluster ID, lifeCycle Parameters and Cloud Artifacts.</p> | | +| Step 14 (M) | <p>DEPLOYMENT</p> <p>The deployment tool requests for the deployment operation towards O2 DMS over the O2dms Interface.</p> <p>The Inventory is updated within the SMO for the deployment.</p> | | +| Ends When | The application has been deployed to the appropriate cluster. This use case ends when the containerized workload is up and running in a suitable Kubernetes cluster. | | +| Exceptions | Exceptions – A failed deployment occurs; thus, the application could not be deployed. A cluster that matches the requirements was not available for this deployment. | | +| Post-conditions | <p>Success – In a successful post-condition, the containerized workload is up and running in the chosen Kubernetes cluster with a given cluster ID. O1 registration occurs with the PNF/xNF registering with O1.</p> <p>Failure – The post-condition upon a failure the deployment did not occur. It is expected that the O-Cloud & O-Cloud infrastructure resources are in the same state.</p> <p>For further details see the instantiate use case in K8s [12] and NFV profiles [11]. and instantiate Use Case in Orchestration Use Case.</p> | | +| Traceability | (See Requirements Below) [REQ-ORC-xx+1], [REQ-ORC-xx+2], [REQ-ORC-xx+3], [REQ-ORC-xx+4], [REQ-ORC-xx+5], [REQ-ORC-xx+6] | | + +### 5.1.4 Recommended Requirements for Deployment Flow for ASD and Cloud Native Artifacts Use Cases + +ORCHESTRATION REQUIREMENTS RELATED TO O2 (Recommended section for the Orchestration & Cloudification Use Case document) + +#### POTENTIAL NEW REQUIREMENTS: + +**Table 5.1.4-1 Recommended Requirements for Deployment flow for ASD** + +| | | | +|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------| +| [REQ-ORC-xx+1] | The deployment descriptors provided for the NF deployment shall contain necessary information to enable the SMO, together with other input data received from the cloud operator to perform a homing decision. | Deployment Flow for ASD And Cloud Native Artifacts Use Case | +| [REQ-ORC-xx+2] | The DeploymentDescriptor (e.g., ASD) shall contain deployment parameters to enable the SMO to perform application deployment.<br>Note: for further information on the DeploymentDescriptor and Information Model (IM) see reference [13]. | Deployment Flow for ASD And Cloud Native Artifacts Use Case | +| [REQ-ORC-xx+3] | The DeploymentDescriptor (e.g., ASD) shall contain “lifecycleParameters” to support the SMO to map cloud operator customizable deployment parameters for the application deployment.<br>Note: For further information about the “lifecycleParameters” see reference [13]. | Deployment Flow for ASD And Cloud Native Artifacts Use Case | +| [REQ-ORC-xx+4] | The DeploymentDescriptor shall support providing default values in the chart enabling the SMO (Orchestrator & Deployment Tools) to complement them with instance specific parameter values in order to construct a values file. | Deployment Flow for ASD And Cloud Native Artifacts Use Case | +| [REQ-ORC-xx+5] | The DeploymentDescriptor (e.g., ASD) shall contain necessary deployment information enabling the SMO (Orchestrator & Deployment Tools) to render corresponding concrete K8s manifest descriptions.<br>Note: This aspect is under investigation and will be reflected in a future version of this document. | Deployment Flow for ASD And Cloud Native Artifacts Use Case | +| [REQ-ORC-xx+6] | The DeploymentDescriptor (e.g., ASD) shall have workload descriptors that can be parsed by the SMO.<br>Note: This aspect is under investigation and will be reflected in a future version of this document | Deployment Flow for ASD And Cloud Native Artifacts Use Case | +| [REQ-ORC-xx+7] | The DeploymentDescriptor (e.g., ASD) shall support describing resource requirements to enable the SMO (Orchestrator & Deployment Tools) to extract cloud resource requirements including but not limited to quantitative requirements. | Deployment Flow for ASD And Cloud Native Artifacts Use Case | + +## 5.2 Deployment flow for VNFD use case + +### 5.2.1 Introduction + +Clause 5.2 describes a use case and flow to deploy an application, such as an NF Deployment into the O-Cloud, using the ETSI NFV defined Virtualised Network Function (VNF) Descriptor (VNFD) specified in ETSI GS NFV-IFA 011 [3]. + +NOTE 1: It is assumed in the use case flow that the SMO interacts with an O-Cloud DMS based on the O2-D demarcation #1 documented in the O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4]. The use case flow could be revisited, or new ones be derived, in future versions of the present document based on further updates performed to the referenced document. + +NOTE 2: The use case flow illustrates interactions among entities within the SMO and between the SMO and the O-Cloud. Clause 2.3.2 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4] provides the mapping and correspondence of management functions and functional blocks between the O-RAN and ETSI NFV architectural frameworks. + +### 5.2.2 UML sequence diagram + +Figure 5.2.2-1 illustrates the use case flow for the instantiation of an NF Deployment based on VNFD. + +![Sequence diagram for NF Deployment instantiation with VNFD. The diagram shows interactions between Personnel (Cloud operator), SMO (NFO, FOCOM, Package repository), and O-Cloud (DMS). The process starts with a precondition and a trigger, followed by a request for NF Deployment instantiation. The SMO then processes the request, including getting VNFD, checking requirements, coordinating with FOCOM to check O-Cloud availability, and processing homing. An alternative path handles successful vs. unsuccessful homing. The process continues with a request for NF Deployment instantiation, an optional step for fetching VNFD and other content, and a reference to the NF Deployment instantiation procedure. Another alternative path handles successful vs. unsuccessful instantiation, including updating runtime and inventory information. The process ends with a request for NF Deployment instantiation and a postcondition.](4531e9334539f54947a26f50080ba4d2_img.jpg) + +**Precondition:** +The Cloud operator has required privileges to instantiate the NF +The App Package for NF Deployment is onboarded and cataloged in the Package repository, and it is valid as per VNF Package specification +SMO has connectivity to the O-Cloud +O-Cloud has registered its DMS with the SMO + +**Trigger:** +The operator requests the instantiation of the NF Deployment + +**1 Request NF Deployment instantiation** + +**NF Deployment instantiation processing** + +**2 Get VNFD of the NF Deployment from Application Package** (See note at the top of UML) + +**3 Check NF Deployment requirements from VNFD** + +**NFO coordination with FOCOM to check O-Cloud availability** + +**4 Check O-Cloud inventory, capacity and resources availability of O-Cloud** (See note at the top of UML) + +**5 NF Deployment homing processing and decision** + +**alt [Successful homing]** +**6 SMO about the homing decision and** + +**[No successful homing]** +**7 Unsuccessful NF Deployment instantiation** + +**Use case ends** + +**8 Request NF Deployment instantiation** + +**opt [Fetching of VNFD and other content]** +**9 Request necessary Application Package content** (O-Cloud DMS uses the VNFD for the NF Deployment instantiation) + +**ref** +NF Deployment instantiation procedure (refer to clause 2.4.2.1 of O-RAN.WG6.02DMS-INTERFACE-ETSI-NFV-PROFILE) + +**alt [Successful instantiation]** +**10 Inform about successful instantiation** +**11 Update necessary runtime and inventory information** + +**[No successful instantiation]** +**12 Inform about unsuccessful instantiation** +**13 Release granted/reserved resources and update of necessary inventory information** + +**14 Inform result of NF Deployment instantiation** + +**Postcondition:** +The NF Deployment is instantiated on the O-Cloud + +Sequence diagram for NF Deployment instantiation with VNFD. The diagram shows interactions between Personnel (Cloud operator), SMO (NFO, FOCOM, Package repository), and O-Cloud (DMS). The process starts with a precondition and a trigger, followed by a request for NF Deployment instantiation. The SMO then processes the request, including getting VNFD, checking requirements, coordinating with FOCOM to check O-Cloud availability, and processing homing. An alternative path handles successful vs. unsuccessful homing. The process continues with a request for NF Deployment instantiation, an optional step for fetching VNFD and other content, and a reference to the NF Deployment instantiation procedure. Another alternative path handles successful vs. unsuccessful instantiation, including updating runtime and inventory information. The process ends with a request for NF Deployment instantiation and a postcondition. + +Figure 5.2.2-1 Flow of NF Deployment instantiation with VNFD + +### 5.2.3 Sequence table + +Table 5.2.3-1 Flow of NF Deployment instantiation with VNFD + +| Use Case Stage | Evolution / Specification | <<Uses>><br>Related use | +|----------------|---------------------------|-------------------------| +|----------------|---------------------------|-------------------------| + +| | | | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------| +| Goal | Application deployment (NF Deployment) into the O-Cloud using VNFD. | | +| Actors and Roles | <p>Cloud operator: an operator of the O-RAN NF and O-Cloud.</p> <p>SMO logical functions: NFO, FOCOM</p> <p>Package repository within SMO (see note 1)</p> <p>O-Cloud DMS: the O-Cloud Deployment Management Services.</p> <p>NOTE 1: It is out of scope of the present document to specify whether the SMO supports package repository functions and/or services.</p> | | +| Assumptions | O-Cloud DMS offers NF Deployment management functionality according to the O2-D demarcation #1 documented in O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4]. | | +| Pre-conditions | <p>1) The Cloud operator has required privileges to instantiate the NF</p> <p>2) The Application Package for NF Deployment, which includes the VNFD and other artifacts, is onboarded and catalogued, and it is valid as per VNF Package and VNFD specification (reference is provided to ETSI GS NFV-IFA 011 [3] as "VNF Package and VNFD specification").</p> <p>3) SMO has connectivity to O-Cloud</p> <p>4) O-Cloud has registered its DMS with the SMO.</p> | | +| Begins when | Cloud operator requests the instantiation of an NF Deployment. | | +| Step 1 (M) | Cloud operator requests to instantiate an NF Deployment based on a VNFD, which is identified in the request. The VNFD contains one or more DeploymentItems describing the requirements for the NF Deployment. | | +| Step 2 (M) | NFO queries the Package repository to get the VNFD from the Application Package corresponding to the NF Deployment requested to be instantiated. | | +| Step 3 (M) | NFO checks the NF Deployment metadata, resource requirements (types and amount), deployment lifecycle parameters and deployment items information from the VNFD. | | +| Step 4 (M) | NFO coordinates with FOCOM to check O-Cloud inventory, capacity and resources availability of the O-Cloud. The request could include a list of identified O-Cloud Sites, if a pre-selection or requirements about specific NF Deployment location are available to the NFO (e.g., provided by the Cloud operator), so that O-Cloud DMS instance that matches the application requirements is selected | | +| Step 5 (M) | <p>NFO performs an NF Deployment homing, which determines the O-Cloud (see note 2) and the respective O-Cloud DMS responsible for the NF Deployment instantiation.</p> <p>NOTE 2: It is assumed that the NF Deployment instantiation is confined to a single O-Cloud.</p> | | +| Step 6 (M) | In case of successful homing, the NFO updates inventory information in the SMO based on the homing decision. The NFVO also prepares necessary input data for the NF Deployment instantiation request. | | +| Step 7 (M) | In case of unsuccessful homing, the NFO informs the Cloud operator of unsuccessful NF Deployment instantiation. | | +| Step 8 (M) | NFO requests the O-Cloud DMS to instantiate the NF Deployment. The instantiation request(s) can provide necessary input lifecycle and configuration data for the instantiation. Information about granted resources, target O-Cloud and placement constraints for the NF Deployment can also be provided. | | +| Step 9 (M) | In case the O-Cloud DMS does not have the VNFD and/or other information needed for the instantiation of the NF Deployment (e.g., certain artifacts), the DMS fetches from the Package repository the necessary content of the Application Package. | | +| | O-Cloud DMS proceeds with NF Deployment instantiation as described in clause 2.4.2.1 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE. The O-Cloud DMS uses the information provided at runtime on the request, information from the VNFD and contents from the Application Package to perform the allocation of necessary O-Cloud resources for the NF Deployment. | Clause 2.4.2.1 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | +| Step 10 (M) | In case of successful instantiation of the NF Deployment, the O-Cloud DMS updates the runtime information of the NF Deployment and informs to the NFO of the successful instantiation. | | +| Step 11 (M) | NFO updates the inventory information according to the successful NF Deployment instantiation. | | + +| | | | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| Step 12 (M) | In case of unsuccessful instantiation of the NF Deployment, the O-Cloud DMS informs to the NFO about the failures/errors. The O-Cloud DMS proceed with the rollback of the instantiation. | | +| Step 13 (M) | NFO proceeds with necessary rollback handling, freeing any of the granted/reserved resources for the NF Deployment and updating the inventory information considering the unsuccessful instantiation. | | +| Step 14 (M) | NFO informs the Cloud operator about the result (either successful or not successful) of the instantiation of the NF Deployment. | | +| Ends when | The Cloud operator is informed about the NF Deployment instantiation result. | | +| Exceptions | <ul style="list-style-type: none"> <li>- NF Deployment homing fails: O-Cloud does not have enough or required resources for the NF Deployment.</li> <li>- NF Deployment instantiation fails: O-Cloud DMS notifies SMO and SMO informs Cloud operator, and granted/reserved resources are freed, and inventory data is updated accordingly.</li> </ul> | | +| Post-conditions | The NF Deployment is instantiated on the O-Cloud. | | +| Traceability | REQ-SMO-VNFD.0a, REQ-SMO-VNFD.0b, REQ-SMO-VNFD.0c, REQ-SMO-VNFD.0d, REQ-SMO-VNFD.0e, REQ-SMO-VNFD.0f | | + +### 5.3.2 Potential New Requirements for Deployment flow for VNFD Use Case + +Table 5.2.4-1 lists potential requirements related to VNFD support application deployment. + +**Table 5.2.4-1: Potential requirements related to VNFD for application deployment** + +| Identifier | Requirement | Additional notes | +|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------| +| REQ-SMO-VNFD.0a | The deployment descriptors provided for the NF Deployment shall contain necessary information to enable the SMO, together with other input data received from the Cloud operator, perform a homing decision for the application deployment. | Deployment flow for VNFD use case | +| REQ-SMO-VNFD.0b | The DeploymentDescriptor (e.g., VNFD) shall contain NF Deployment resource requirements (type and amount) and NF Deployment units' affinity/anti-affinity constraints to enable the SMO (NFO) to parse, process and use the deployment information for the application deployment. | Deployment flow for VNFD use case | +| REQ-SMO-VNFD.0c | The DeploymentDescriptor (e.g., VNFD) shall support defining lifecycle parameters for the corresponding NF Deployment to enable the SMO (NFO) to parse, process and determine the lifecycle operation to perform. | Deployment flow for VNFD use case | +| REQ-SMO-VNFD.0d | The DeploymentDescriptor (e.g., VNFD) shall support defining necessary input lifecycle parameters to enable the SMO (NFO) to assign corresponding values from input data provided to the SMO when requesting the O-Cloud DMS the NF Deployment lifecycle operation. | Deployment flow for VNFD use case | +| REQ-SMO-VNFD.0e | The DeploymentDescriptor (e.g., VNFD) shall support defining necessary input lifecycle parameters to enable the SMO (NFO) generate, based on orchestration runtime data, corresponding values when requesting the O-Cloud DMS the NF Deployment lifecycle operation. | Deployment flow for VNFD use case | +| REQ-SMO-VNFD.0f | The DeploymentDescriptor (e.g., VNFD) shall conform to a VNF Package and VNFD specification to enable the SMO (NFO) to check if an onboarded application package is valid. | Deployment flow for VNFD use case. Reference is provided to ETSI GS NFV-IFA 011 [3] as "VNF Package and VNFD specification". | + +# 6 Information Requirements for K8s-Aware Solution + +## 6.1 DeploymentDescriptor with Application Service Descriptor + +Application Service Descriptor (ASD) describes application metadata for the orchestrator to be used as input for deployment of an application workload that is described by the ASD. + +### 6.1.1 Conventions + +The attributes of the ASD information elements are described in the tables provided in section 6.1. Each table has 5 columns, with the following significance: + +- The "Attribute" column provides the attribute name. +- The "Qualifier" column indicates whether the support of the attribute is mandatory, optional or conditional from the SMO perspective. +- The "Cardinality" column contains the minimum and maximum cardinality of this information element (e.g., 1, 0 ... N, 1 ... N). A cardinality range starting with 0 indicates that the attribute need not always be included and 1 indicates that the attribute needs to be always included. +- The "Type" column provides information on the type of the attribute values. It can be the name of an Information Element. If a cell in the "Type" is marked as "Not specified", which indicates that the specification of the type is left to the data model. +- The "Description" provides a brief explanatory description, additional constraints, and examples. + +The ASD is a complementary descriptor to the cloud-native deployment artifacts hence it contains design-time information provided by the application vendor that is not described/available in the cloud native artifacts. Such complementary information in the ASD can include specific infrastructure capabilities requirements for the deployment of the application software workload, constraints on the Kernel type needed, additional networking requirements needed beyond primary connectivity described in the cloud native artifacts, any special CNI (Container Network Interfaces), etc. + +ASD can support an application workload deployment on OS container infrastructures, and it is applicable to O-RAN NFs, xApps, and rApps. + +The following figure illustrates the representation of O-RAN OAM Application Packaging Model [WG10. Common Package] and shows how the Application Service Descriptor is positioned within the Application Package Model. + +![Figure 6.1.1-1: DeploymentDescriptor with ASD representation. The diagram shows a hierarchical structure of O-RAN OAM Application Packaging Model. On the left, a vertical flow shows 'ASD (DeploymentDescriptor)' having a 'has' relationship with 'ASD DeploymentItem (DeploymentItem)', which in turn has a 'has' relationship with 'Helm Chart (CloudNative DescriptorFile)', which may have a 'May have' relationship with 'DockerImage (ExecutableImage)'. A dashed blue box encloses these four elements, labeled 'Deployment related artifacts'. On the right, a more detailed graph shows the relationships between various descriptors. 'AppPackage' (red) has 'Has' relationships with 'DeploymentDescriptor' (blue), 'MLModelDescriptor' (pink), and 'ManagementDescriptor' (yellow). 'DeploymentDescriptor' has a 'Has' relationship with 'DeploymentItem' (blue). 'DeploymentItem' has a 'May Have' relationship with 'ComponentDescriptor' (yellow). 'ComponentDescriptor' has a 'Has' relationship with 'ManagementDescriptor'. 'ManagementDescriptor' has 'Has' relationships with 'CloudNativeDescriptorFile' (green), 'ExecutableImage' (green), 'TEDescriptor' (pink), 'SecurityDescriptor' (yellow), 'AlarmDictionary' (yellow), 'ConfigurationModel' (yellow), 'AccountingDictionary' (yellow), and 'PerformanceDictionary' (yellow). 'CloudNativeDescriptorFile' has a 'May Have' relationship with 'ExecutableImage'. 'ExecutableImage' has a 'May Have' relationship with 'TEDescriptor'. 'TEDescriptor' has a 'May Have' relationship with 'ComponentDescriptor'. 'ComponentDescriptor' has a 'May Have' relationship with 'MLModelDescriptor'. 'MLModelDescriptor' has a 'May Have' relationship with 'AppPackage'.](228755dceb6360f24aeac70d3607b395_img.jpg) + +Figure 6.1.1-1: DeploymentDescriptor with ASD representation. The diagram shows a hierarchical structure of O-RAN OAM Application Packaging Model. On the left, a vertical flow shows 'ASD (DeploymentDescriptor)' having a 'has' relationship with 'ASD DeploymentItem (DeploymentItem)', which in turn has a 'has' relationship with 'Helm Chart (CloudNative DescriptorFile)', which may have a 'May have' relationship with 'DockerImage (ExecutableImage)'. A dashed blue box encloses these four elements, labeled 'Deployment related artifacts'. On the right, a more detailed graph shows the relationships between various descriptors. 'AppPackage' (red) has 'Has' relationships with 'DeploymentDescriptor' (blue), 'MLModelDescriptor' (pink), and 'ManagementDescriptor' (yellow). 'DeploymentDescriptor' has a 'Has' relationship with 'DeploymentItem' (blue). 'DeploymentItem' has a 'May Have' relationship with 'ComponentDescriptor' (yellow). 'ComponentDescriptor' has a 'Has' relationship with 'ManagementDescriptor'. 'ManagementDescriptor' has 'Has' relationships with 'CloudNativeDescriptorFile' (green), 'ExecutableImage' (green), 'TEDescriptor' (pink), 'SecurityDescriptor' (yellow), 'AlarmDictionary' (yellow), 'ConfigurationModel' (yellow), 'AccountingDictionary' (yellow), and 'PerformanceDictionary' (yellow). 'CloudNativeDescriptorFile' has a 'May Have' relationship with 'ExecutableImage'. 'ExecutableImage' has a 'May Have' relationship with 'TEDescriptor'. 'TEDescriptor' has a 'May Have' relationship with 'ComponentDescriptor'. 'ComponentDescriptor' has a 'May Have' relationship with 'MLModelDescriptor'. 'MLModelDescriptor' has a 'May Have' relationship with 'AppPackage'. + +Figure 6.1.1-1 DeploymentDescriptor with ASD representation + +### 6.1.2 Application Service Descriptor + +For the O-RAN NFs the Application Service Descriptor (ASD) is a main top level descriptor template which consists of the attributes described in Table 6.2-1 below. + +**Table 6.1.2-1 ASD Information Model** + +| Attribute | Qualifier | Cardinality | Type | Description | +|--------------------------------------------------------------------------------|-----------|-------------|-----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| asdId | M | 1 | Identifier | Identifier of this ASD information element. This attribute shall be globally unique. The format will be defined in the data model specification phase. | +| asdVersion | M | 1 | String | Identifies the version of the ASD | +| asdSchemaVersion | M | 1 | Version | Specifies the version of the ASD's schema.<br><br>Note 1: | +| asdProvider | M | 1 | String | Provider of the application and of the ASD. | +| asdApplicationName | M | 1 | String | Name to identify the application. Invariant for the application lifetime. | +| asdApplicationVersion | M | 1 | Version | Specifies the version of the application.<br><br>Note 2. | +| asdApplicationInfoName | M | 0..1 | String | Human readable name for the application. Can change during the ASD lifetime. | +| asdInfoDescription | M | 0..1 | String | Human readable description of the application. Can change during the ASD lifetime. | +| asdExtCpd | M | 0..N | ExtCpd | Describes the externally exposed connection points of the application. | +| enhancedClusterCapabilities | M | 0..1 | EnhancedClusterCapabilities | A list of expected capabilities of the target deployment cluster to aid placement of the application on a suitable cluster. | +| deploymentItems | M | 1..N | DeploymentItem | Cloud native deployment artifacts associated with the application. | +| asdInvariantId | M | 1 | Identifier | Identifier of this descriptor in a version independent manner. This attribute is invariant across versions of ASD. It is in UUID format as specified in RFC 4122 | +| Note 1: Version change when a change is made to any one of the ASD attributes. | | | | | +| Note 2: Version value change when software or ASD values changes | | | | | + +### 6.1.3 Deployment Item (DeploymentItems) Information Element + +The CloudNativeDescriptorFile defined in [WG10. Common Package] is realized by the deploymentItems IE which has the DeploymentItems structure described in Table 6.3-1 below. + +DeploymentItems IE describes the type of cloud native artifact, its order of deployment in case multiple cloud native artifacts are employed with the same ASD, and the list of parameters that can be parameterized in this cloud native deployment artifact at deployment time. + +**Table 6.1.3-1 DeploymentItems IE** + +| .Attribute | Qualifier | Cardinality | Type | Description | +|------------|-----------|-------------|------|-------------| +|------------|-----------|-------------|------|-------------| + +| | | | | | +|--------------------------------------------------------------------------------------|---|------|------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| deploymentItemId | M | 1 | Identifier | The identifier of this deployment item | +| artifactType | M | 1 | String | Specifies the artifact type. One of following values can be chosen: "helm chart", "helmfile", "crd", "terraform". | +| artifactId | M | 1 | String | Unique reference to a deployment item (cloud native deployment artifact). It can be a URI or file path. | +| deploymentOrder | M | 0..1 | Integer | Specifies the deployment order of the deployment item. A lower value specifies that the deployment item belongs to an earlier deployment stage, i.e., needs to be installed prior to a deployment item with higher deploymentOrder values. If not specified, the deployment of the deployment item can be done in arbitrary order and decided by the orchestrator. | +| lifecycleParameters | M | 0..N | String | The list of parameters that can be overridden at deployment time (e.g., the list of parameters in the values.yaml which can be overridden at deployment time) | +| Note 1: An initial list of artifactType. Other type of artifact is for further study | | | | | + +### 6.1.4 External connection point (asdExtCpd) Information Element + +ExtCpd describes application exposing endpoints to enable orchestrators to string together or optimally place linked applications. + +**Table 6.1.4-1 ExtCpd Information Element (IE)** + +| Attribute | Qualifier | Cardinality | Content | Description | +|-----------------------------------------|-----------|-------------|-----------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| id | M | 1 | String | The identifier of this ExtCpdData | +| description | M | 1 | String | Describes the service exposed. | +| virtualLinkRequirement | M | 1 | String | Refers in an abstract way to the network that the ExtCpd shall be exposed for (ex: OAM, EndUser, backhaul, LI, etc). The intent is to enable a network operator to identify which extCpd was designed to be connected to which VPN. . | +| networkInterfaceRealizationRequirements | M | 0..1 | NetworkInterfaceRealizationRequirements | Details container implementation specific requirements on the NetworkAttachmentDefinition. See Note 1 & 2. | +| inputParamMappings | M | 0..1 | ExtCpd.ParamMappings | Information on what parameters is required to be provided to the deployment tools for the asdExtCpd instance. | +| resourceMapping | M | 0..1 | String | Resource name for the cloud native resource manifest, as specified in the cloud native descriptor declaring the network interface (e.g., in the helm.chart, for the: service, ingress or pod resource). Enables, together with knowledge on namespace, the orchestrator to lookup the runtime data related to the extCpd. | + +**Note 1: Applies only for ExtCpd representing secondary network interfaces in a POD.** + +**Note 2: Several ExtCpd may refer to same additional network interface requirements.** + +### 6.1.5 NetworkInterfaceRealizationRequirements Information Element + +NetworkInterfaceRealizationRequirements IE describes details related to secondary networks that attach the OS containers to the logical or physical networks. + +**Table 6.1.5-1 NetworkInterfaceRealizationRequirements IE** + +| Attribute | Qualifier | Cardinality | Content | Description | +|---------------------|-----------|-------------|-------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| trunkMode | M | 0..1 | "false" or "true" | If not present or set to "false", means that this interface shall connect to single network. If set to "true" then the network interface shall be a trunk interface (connects to multiple VLANs). | +| ipam | M | 0..1 | "infraProvided", "orchestrated", "userManaged" | The default value ("infraProvided") means that the CNI specifies how IPAM is done and assigns the IP address to the pod interface. | +| interfaceType | M | 0..1 | "kernel.netdev", "direct.userdriver", "direct.kerneldriver", "direct.bond", "userspace" | This attribute is applicable for passthrough and memif interfaces. Value default value is "kernel.netdev". | +| interfaceOptions | M | 0..N | "virtio", "memif" | Alternative vNIC configurations the network interface is verified to work with. | +| interfaceRedundancy | M | 0..1 | "infraProvided",<br><br>"left", "right",<br><br>"activeActiveBond",<br>"activePassiveBond",<br>"activePassive13", | <p>"infraProvided" The application sees one vNIC, but the infrastructure provides redundant access to the network via both switch planes. For interface of type kernel.netdev the redundancy is provided by the vSwitch or Linux bonding. For interfaces of type direct, it requires that the physical NIC is connected to both switch planes (a.k.a. smartNIC). Thus, it imposes hardware requirements on the infrastructure. For interface of type userspace redundancy handled by a DPDK-OVS or VPP vSwitch "left" and "right" indicates a vNIC connected non-redundantly to the network via one specific (left or right) switchplane.</p> <p>All other attributes indicate a mated vNIC pair in the Pod, one connecting to the network via left switchplane and the other connecting to the network via the right switchplane, and with application using them together as a redundant network interface using a particular redundancy method that need to be accommodated in the node infrastructure.</p> <p>"activeActiveBond": Requires a static multi-chassis LAG in active-active mode from the infrastructure. Typically corresponds to bonding mode-2 "balance-xor"</p> <p>"activePassiveBond": The interfaces are bonded in active-passive mode in the application with move of bond MAC address. No specific requirements on DC fabric. Typically corresponds to bonding mode-1 "active-backup"</p> <p>"activePassive13": Application moves its IP address by attaching it to one of the two MACs by use of GARP messages.</p> <p>Editor's note: Change the link to reference section<br/> <a href="https://nfvwiki.etsi.org/index.php?title=Cni..">https://nfvwiki.etsi.org/index.php?title=Cni..</a></p> | +| nicOptions | M | 0..N | "i710",<br><br>"e810",<br><br>"mlx-cx5",<br><br>"mlx-cx6" | <p>nics a direct user space driver the application is verified to work with. The content aligned with ETSI HPC registry</p> <p>Editor's note: Change the link to reference section<br/> <a href="https://nfvwiki.etsi.org/index.php?title=Cni..">https://nfvwiki.etsi.org/index.php?title=Cni..</a></p> | + +### 6.1.6 ExtCpdParamMappings Information Element + +ExtCpdParamMappings IE describes required information on what parameters to be provided to the deployment tools for the ExtCpd instance. + +**Table 6.1.6-1 ExtCpdParamMappings IE** + +| Attribute | Qualifier | Cardinality | Content | Description | +|----------------|-----------|-------------|---------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| loadbalancerIP | M | 0..1 | String | When present, this attribute specifies the name of the deployment artifact input parameter through which the orchestrator can configure the loadbalancerIP parameter of the K8s service or ingress controller that the ExtCpd represents.<br><br><i>Note 2</i> | +| externalIPs | M | 0..N | String | When present, this attribute specifies the name of the deployment artifact input parameter through which the orchestrator can configure the externalIPs parameter of the K8s service or ingress controller, or the pod network interface annotation, that the ExtCpd represents. The param name and provided IP address(es) value will be passed to the deployment tool when deploying the <i>DeploymentArtifacts</i> .<br><br><i>Note 2</i> | +| nadNames | M | 0..N | String | These attributes specify, for an ExtCpd representing a secondary network interface, the name(s) of the deployment artifact input parameter(s) through which the orchestrator can provide the names of the network attachment definitions (NADs) the orchestrator has created as base for the network interface the ExtCpd represents.<br><i>It is expected that the NADs themselves have been created prior to the deployment of the deployment artifacts.</i><br><br><i>Note 1,2,3</i> | +| nadNamespace | M | 0..1 | String | Specifies, for an ExtCpd representing a secondary network interface, the name of the deployment artifact input parameter through which the orchestrator can provide the namespace where the NADs are located.<br>Attribute may be omitted if the namespace is same as the application namespace.<br><br><i>Note 2</i> | + +Note 1: When the ExtCpd represent a networkRedundant/mated pair of sriov interfaces, there are references to 2 or 3 related NADs needed to be passed, while for other interface types only one NAD reference is needed to be passed. + +Note 2: The format of the Content strings is specific for each different orchestration templating technology used (Helm, Teraform, etc.). Currently only a format for use with Helm charts is suggested: "<helmchartname>:[<subchartname>.] 0 ... N[<parentparamname>.] 0 ... N<paramname>". Whether the optional parts of the format are present depends on how the parameter is declared in the helm chart. An example is: "chartName:subChart1.subChart2.subChart3.Parent1.Parent2.Parent3.parameter". + +Note 3: A direct attached (passthrough) network interface, such as an sriov interface, attaches to a network via only one of the two switch planes in the infrastructure. +When using a direct attached network interface one therefore commonly in a pod uses a mated pair of sriov network attachments, where each interface attaches same network but via different switchplane. +The application uses the mated pair of network interfaces as a single logical "swith-path-redundant" network + +interface – and this is represented by a single ExtCpd. + +Also, there is a case where a third “bond” attachment interface is used in the pod, bonding the two direct interfaces so that the application does not need to handle the redundancy issues – application just uses the bond interface. + +In this case all three attachments are together making up a logical “switch-path-redundant” network interface represented by a single ExtCpd. When three NADs are used in the ExtCpd the NAD implementing the bond attachment interface is provided through the parameter indicated in the third place in the nadNames attribute. + +### 6.1.7 EnhancedClusterCapabilities Information Element + +EnhancedClusterCapabilities IE describes information which is used to aid placement of the application service on a suitable cluster. + +**Table 6.1.7-1 EnhancedClusterCapabilities IE** + +| Attribute | Qualifier | Cardinality | Content | Description | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------|-------------|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| minKernelVersion | M | 1 | String | Describes the minimal required Kernel version, e.g., 4.15.0. Coded as displayed by linux command <code>uname -r</code> | +| requiredKernelModules | M | 0..N | String | Required kernel modules are coded as listed by linux <code>lsmod</code> command, e.g., <code>ip6_tables</code> , <code>cryptd</code> , <code>nf_nat</code> etc. | +| conflictingKernelModules | M | 0..N | String | Kernel modules, which must not be present in the target environment. The kernel modules are coded as listed by linux <code>lsmod</code> command, e.g., <code>ip6_tables</code> , <code>cryptd</code> , <code>nf_nat</code> etc. Example: Linux kernel SCTP module, which may conflict with use of proprietary user space SCTP stack provided by the application. | +| requiredCustomResources | M | 0..N | Structure (inlined) | List the required custom resource types in the target environment, identifying each by the "kind" and "apiVersion" field in the K8S resource manifests and in the application. The list shall include those custom resource types which are not delivered with the application.<br><br>Example:<br>requiredCustomResources:<br>-{kind: "Redis", apiVersion: " <a href="#">kubedb.com/v1alpha1</a> "} | +| >kind | M | 0..1 | String | Kind of the custom resource | +| >apiVersion | M | 0..1 | String | apiVersion of the custom resource | +| clusterLabels | M | 0..N | String | This attribute indicates the required O-Cloud Node Cluster capabilities.<br><br>These can indicate special infrastructure capabilities (e.g., NW acceleration, GPU compute, etc.). The intent of these O-Cloud Node Cluster capabilities is to serve as a set of values that can support the SMO in application placement decisions. See note 1.<br><br>clusterLabels follow the Kubernetes label key-value-nomenclature [5] . This attribute should use the <u>standardized values for the O-RAN O-Cloud Node Cluster capabilities [reference tbd], the existing values for node features [6], and any new capabilities identified in O-RAN specifications and allows also vendor-specific extensions.</u> | +| requiredPlugin | M | 0..N | Structure (inlined) | A list of the names and versions of the required K8s plugin (e.g., multus v3.8) | +| >requiredPluginName | M | 0..1 | String | The names of the required K8s plugin (e.g., multus) | +| >requiredPluginVersion | M | 0..1 | String | The version of the required plugin (e.g., 3.8) | +| Note 1: The SMO uses the set of standardized capabilities to identify O-Cloud Node cluster capabilities required in the DeploymentDescriptors and to match them to the capabilities available in the O-Cloud. | | | | | + +### 6.1.8 Metadata + +NOTE: Content is expected in future versions of the present document. + +### 6.1.9 Security + +NOTE: Content is expected in future versions of the present document. + +### 6.1.10 Resource Requirements + +NOTE: Content is expected in future versions of the present document. + +### 6.1.11 DeploymentItems + +NOTE: Content is expected in future versions of the present document. + +### 6.1.12 Other + +NOTE: Content is expected in future versions of the present document. + +## 6.2 DeploymentItem + +### 6.2.1 Deployment Sequencing + +NOTE: Content is expected in future versions of the present document. + +### 6.2.2 Lifecycle Requirements + +NOTE: Content is expected in future versions of the present document. + +# --- 7 Information Requirements for ETSI-based Solution + +## 7.1 DeploymentDescriptor + +NOTE: Content is expected in future versions of the present document. + +## 7.2 DeploymentItems + +NOTE: Content is expected in future versions of the present document. + +# --- 8 Formatting Recommendations + +## 8.1 CSAR + +NOTE: Content is expected in future versions of the present document. + +## 8.2 SOL004 + +NOTE: Content is expected in future versions of the present document. + +# --- 9 Recommendations + +## 9.1 Introduction + +This TR is structured in a modular fashion organized by major topics and the following sections provide relevant recommendations by topic. + +## 9.2 Recommendation for Deploy flow use case & requirements + +The deployment flow use case for ASD is recommended to be incorporated into the Cloudification & Orchestration Use Case and Requirements document. + +**Some part of the flow is relevant to WG1 & WG10 OAM Architecture document.** + +**Some part of the flow is relevant to WG6 for interaction between NFO & DMS.** + +The deployment flow based on ASD does not show interactions between NFO & DMS beyond those that are just stating “request to deploy”. So, it is not clear what needs to be documented in the Orchestration Use Case Specification. This still has yet to be resolved. + +**SUMMARY:** The recommendation from this TR is that Deployment Flow Use cases should go into the Cloudification & Orchestration Use Case and Requirements specification. + +## 9.3 Recommendation for DeploymentDescriptor based on ASD + +This is described in Clause 6.1 and Clause 6.2 + +The team producing this TR has considered four options for where that content might be placed: + +### **(1) O2 DMS Interface Spec (new) WG6 Stage 2 –** + +The O2 DMS Interface Specification would be a sister document in WG6 to the existing O2 IMS Interface Specification. It would be a new document which would also be the home for other O2 DMS topics, such as O2 DMS fault and O2 DMS performance management. So, it could be created for DeploymentDescription as well as the other O2 DMS topic areas. + +### **(2) WG10 App Pkg Spec [out of place wrong WG]** + +Another possibility is to put into the WG10 App Package Specification; however, it is not proper working group. + +### **(3) O2 DMS LCM - O2 DeploymentDesc for ASD (new WG6 document)** + +A new separate dedicated for ASD modelling could be an option. + +### **(4) O2 DMS K8s Profile [this is a Stage 2 material being put into Stage 3 document]** + +Incorporating the material into the Stage 3 O2 DMS K8s Profile document. The problem with that is that it is stage 2 material going into a stage 3 document. + +**SUMMARY:** This TR recommends that a new specification is created for the ASD content as described in Option #3. The content in Clause 6 from the present document can be used as the seed content and baseline for the new ASD specification. + +## 9.4 Recommendation for DeploymentDescriptor based on VNFD + +Recommendation for Deployment Flow for VNFD Use Case + +**Some part of the flow is relevant to WG1 & WG10 OAM Architecture document** + +**Some part of the flow is relevant to WG6 for interaction between NFO & DMS.** + +**SUMMARY:** The recommendation from this TR is that Deployment Flow for Deployment Descriptor based on VNF use cases should go into the Cloudification & Orchestration Use Case and Requirements specification. + +# Revision History + +**Table – Revision History** + +| Date | Revision | Description | +|---------------|----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| July , 2023 | 02.00 | Incorporated CR to update Security and Recommendations section:<br>- NOK-2023.06.30-CR0060-WG6 AppLCMDeployment-v01.00 | +| Mar 08, 2023 | 00.10 | Addition of Deployment Flow for VNFD Use Case<br><ul style="list-style-type: none"><li>• Clause 5.2.1 and Clause 5.2.2 addition of Deployment Flow for VNFD Use Case</li></ul> | +| June 02, 2022 | 00.01 | Initial Draft Discussion versions | + +## --- History + +History of the Document + +**Table - History of the Document** + +| Date | Revision | Description | +|---------|----------|----------------------------------| +| 2023.03 | 01.00 | Published as Final version 01.00 | \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/14b14f5fc10878d3a0cfc134e7fb7821_img.jpg b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/14b14f5fc10878d3a0cfc134e7fb7821_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4e46e71b66d8e2b958ce90ccc8fa155f0fae40f4 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/14b14f5fc10878d3a0cfc134e7fb7821_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e1b1d7182499758360835a70e673b0f7fe4bc0d0935f52ae0d9f627703b86333 +size 143397 diff --git a/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/51b4906b9379351e8b2aca58c4d6ee14_img.jpg b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/51b4906b9379351e8b2aca58c4d6ee14_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c5c6fd3ba38d7d3881c6836ab72c888b45162e8f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/51b4906b9379351e8b2aca58c4d6ee14_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e38483cbf6d1bdd04438a1570335a80b7de97cc9a175d47bbc542bb5456e4bb3 +size 4563 diff --git a/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3a71b98fcfc274b0603208cc5e23601d7fc924a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84a0e505aa8e8fcec39c03736b466858a7c1ef91abe309cdd2974ee18257e23b +size 4531 diff --git a/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/61596f4d6b34e473ef4ff53ba635e0fd_img.jpg b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/61596f4d6b34e473ef4ff53ba635e0fd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bf471254eafd39b4726e1e5cce8fe4b2dd8bcfdb --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/61596f4d6b34e473ef4ff53ba635e0fd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a208a3a99898f7e584494f825115e7e9bd4add8debeba9f4a8619d4d9fd2f443 +size 139000 diff --git a/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82827af191c934857f3a5a97842fa19fb4aa5978 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54f690c723a011f67b244eeda5cca1f67e7a7784e122d72a637cea1ca968c8f4 +size 4531 diff --git a/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f9786619d9266ddf6962b7631fad8834bd583a3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:17a48c732b82959a70a4744afdf56099b05c77a70dfcfaa935549c6ab678bec2 +size 4509 diff --git a/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/raw.md b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..d7d1869fe2a3db1db8f05a9bad2af657271f7f61 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL FEC.R004-v04.00/raw.md @@ -0,0 +1,589 @@ + + +# --- **O-RAN Work Group 6 Acceleration Abstract Layer FEC Profiles** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|----------------------------------------------------------|-----------| +| List of figures ..... | 5 | +| List of tables ..... | 5 | +| Foreword..... | 6 | +| Modal verbs terminology ..... | 6 | +| Executive summary ..... | 6 | +| Introduction ..... | 6 | +| 1 Scope..... | 7 | +| 2 References ..... | 7 | +| 2.1 Normative references ..... | 7 | +| 2.2 Informative references ..... | 8 | +| 3 Definition of terms, symbols, and abbreviations ..... | 8 | +| 3.1 Terms ..... | 8 | +| 3.2 Symbols..... | 8 | +| 3.3 Abbreviations..... | 8 | +| 4 Overview ..... | 9 | +| 4.1 Purpose..... | 9 | +| 4.2 Document Structure ..... | 12 | +| 5 AALi Configuraton and Management..... | 13 | +| 5.1 AAL Configuration and Management ..... | 13 | +| 5.2 Initalization and Configuration ..... | 13 | +| 5.2.1 Get Number of AAL LPU's..... | 13 | +| 5.2.2 Get AAL-LPU Fine Grained Capabilities..... | 13 | +| 5.2.3 Setup and Allocate AAL LPU Queues ..... | 14 | +| 5.2.4 Configure AAL-LPU Queues ..... | 14 | +| 5.3 AAL-LPU Management and AAL-LPU Queue management..... | 14 | +| 5.4. AAL Statistics..... | 14 | +| 6 AAL Profile Specifications ..... | 15 | +| 6.1 Profile Specifications Overview ..... | 15 | +| 6.1.1 Operation Representation..... | 15 | +| 6.1.2 Profile Capabaillities..... | 16 | +| 6.1.3 Memory Management..... | 16 | +| 6.2 O-DU AAL PDSCH FEC Profile Specification ..... | 16 | +| 6.2.1 AAL FEC PDSCH Profile Capabilities ..... | 16 | +| 6.2.2 AAL PDSCH FEC Profile Operations..... | 18 | +| 6.3 O-DU AAL PUSCH FEC Profile Specification ..... | 19 | +| 6.3.1 AAL FEC PUSCH Profile Capabilities ..... | 19 | +| 6.3.2 AAL PUSCH FEC Profile Operations..... | 21 | +| 6.4 AAL Profile API Definitions ..... | 22 | +| 6.4.1 O-RAN AAL FEC API Terminology ..... | 22 | +| <b>Annex (informative): Change History .....</b> | <b>30</b> | + +# List of figures + +| | | +|------------------------------------------|----| +| Figure 4.1-1 AAL_PDSCH_FEC Profile ..... | 10 | +| Figure 4.1-2 AAL_PUSCH_FEC Profile ..... | 11 | + +# --- List of tables + +| | | +|-----------------------------------------------------------------|----| +| Table 5.2.2-1: AAL-LPU Capabilities ..... | 14 | +| Table 5.2.4-1: AAL-LPU Queue Configuration ..... | 15 | +| Table 6.1.1.1-1: AAL_PDSCH_FEC Profile Capabilities..... | 18 | +| Table 6.2.2-1: AAL_PDSCH_FEC Profile parameters ..... | 19 | +| Table 6.2.2.1-1: CB-mode parameters ..... | 19 | +| Table 6.2.2.2-1: TB-mode parameters ..... | 19 | +| Table 6.3.1.2-1: AAL_PUSCH_FEC Profile capabilities ..... | 21 | +| Table 6.3.2-1: AAL_PUSCH_FEC Profile Parameters ..... | 22 | +| Table 6.3.2.1-1: AAL_PUSCH_FEC Profile CB-Mode Parameters ..... | 22 | +| Table 6.3.2.2-1: AAL_PUSCH_FEC Profile TB-Mode Parameters ..... | 23 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG6 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should WG6 the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +## --- Executive summary + +Void + +# --- Introduction + +Void. + +# --- 1 Scope + +The present document specifies the Acceleration Abstraction Layer for the AAL\_PDSCH\_FEC and AAL\_PUSCH\_FEC Profiles as defined in [7], including the AAL and the management and orchestration requirements of AAL-LPUs providing HW Acceleration for the fore mentioned AAL profiles. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. 3GPP references refer to 3GPP release 16. + +- [1] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [2] Void +- [3] WG6 2020 Use Case for BBU Pooling, 2019. +- [4] 3GPP TS 38.211: "NR; Physical channels and modulation". +- [5] 3GPP TS 38.212: "NR; Multiplexing and channel coding". +- [6] Void +- [7] O-RAN WG6 Acceleration Abstraction Layer General Aspects and Principles +- [8] O-RAN WG6 Acceleration Abstraction Layer Common API +- [9] OSC AAL Specifications [o-ran-sc/o-du/phy/aal](https://www.o-ran-sc.org/du/phy/aal) + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i1] O-RAN Software Community <https://wiki.o-ran-sc.org/display/ORAN> +- [i2] DPDK coding style [https://doc.dpdk.org/guides/contributing/coding\\_style.html](https://doc.dpdk.org/guides/contributing/coding_style.html) +- [i3] 3GPP TR 38.300: "NR; NR and NG-RAN Overall Description". + +# --- 3 Definition of terms, symbols, and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in [7] apply. + +## 3.2 Symbols + +For the purposes of the present document, the symbols given in apply: Not applicable + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations apply: + +| | | +|---------|--------------------------------------------------------| +| AAL | Acceleration Abstraction Layer | +| AALi | Acceleration Abstraction Layer interface | +| AAL-LPU | Acceleration Abstraction Layer Logical Processing Unit | +| CB | Code Block | +| CNF | Containerized Network Function | +| NF | Network Function | +| O-CU | O-RAN Centralized Unit | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| OS | Operating System | +| OSC | O-RAN Software Community | +| TB | Transport Block | + +# --- 4 Overview + +## 4.1 Purpose + +The AAL General Aspects and Principles is described in [7] including a high-level architecture of the AAL and definition of the AAL profiles. This document details the AAL specification consisting of the description of the interface, information models and requirements to implement an AALi, for the AAL\_PUSCH\_FEC and AAL\_PDSCH\_FEC Profiles, shown below in Figure 4.1-1 and Figure 4.1-2. + +![](14b14f5fc10878d3a0cfc134e7fb7821_img.jpg) + +| L2+ | | | | | | | | +|-------------------------------------|--|--|--|-------------------------|--|--|--| +| <b>PDSCH TB(s)</b> | | | | <b>PBCH TB</b> | | | | +| TB CRC attachment | | | | PBCH payload generation | | | | +| CB segmentation + CB CRC attachment | | | | Scrambling | | | | +| LDPC encoding | | | | TB CRC attachment | | | | +| Rate matching | | | | Polar encoding | | | | +| CB concatenation | | | | Rate matching | | | | +| Scrambling | | | | <b>PSS/SSS</b> | | | | +| Modulation | | | | <b>PBCH DM-RS</b> | | | | +| Layer mapping | | | | Sequence Generation | | | | +| | | | | Modulation | | | | +| Precoding* | | | | Modulation (QPSK) | | | | +| RE mapping | | | | Precoding* | | | | +| IQ compression* | | | | RE mapping | | | | +| | | | | IQ compression* | | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +Figure 4.1-1 AAL\_PDSCH\_FEC Profile + +![](61596f4d6b34e473ef4ff53ba635e0fd_img.jpg) + +| L2+ | | | | | | | | +|-----------------------------------|--|--|--|-------------------------------|--|--|--| +| <b>PUSCH UL data</b> | | | | <b>PUCCH format 2/3/4 UCI</b> | | | | +| TB CRC check | | | | CRC check | | | | +| CB CRC + CB desegmentation | | | | Polar/Block decoding | | | | +| LDPC decoding | | | | Rate dematching | | | | +| Rate dematching | | | | Descrambling | | | | +| CB deconcatenation | | | | Demodulation | | | | +| Descrambling | | | | IDFT for DFT-s-OFDM | | | | +| Demodulation | | | | Channel equalization | | | | +| IDFT for DFT-s-OFDM | | | | Channel estimation | | | | +| Channel equalization | | | | RE demapping | | | | +| Channel estimation | | | | IQ decompression* | | | | +| RE demapping | | | | IQ decompression* | | | | +| IQ decompression* | | | | IQ decompression* | | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +Figure 4.1-2 AAL\_PUSCH\_FEC Profile + +## 4.2 Document Structure + +This present document is structured as follows: chapter 4 presents the overview and main purpose of this specification. Chapter 5 presents the AAL Hardware Acceleration Management specification for the AAL\_PUSCH\_FEC and AAL\_PDSCH\_FEC Profiles. Chapter 6 presents the common AALi requirements for an AAL-LPU supporting one or more AAL\_PUSCH\_FEC and/or AAL\_PDSCH\_FEC Profiles. + +# 5 AALi Configuraton and Management + +The chapter defines the common configuration and management aspects of the AALi as they relate to the AAL\_PUSCH\_FEC and AAL\_PDSCH\_FEC profiles. The AALi configuration and management APIs are the API's that an AAL application (O-DU) executes to configure and manage the AAL-LPU(s) that have been allocated to the application by the O-Cloud. + +The below section describes the requirements of the AALi presented to the Application. + +## 5.1 AAL Configuration and Management + +## 5.2 Initalization and Configuration + +As per sequence diagram in Chapter 4.1.1.3 in [7] the below list of high-level configuration and management interfaces shall be supported. + +- Get Number of AAL LPU's +- Get AAL LPU Fine Grain capabilities +- Setup and Allocate AAL LPU Queues +- Configure AAL LPU Queues + +### 5.2.1 Get Number of AAL LPU's + +The AALi shall provide an interface to retrieve a count of the number of AAL-LPU's available to be used by the application. + +### 5.2.2 Get AAL-LPU Fine Grained Capabilities + +The AALi shall provide an interface to retrieve the capabilities of an AAL-LPU. The capabilities that shall be reported by the AALi are defined in Table 5.2.2-1. + +**Table 5.2.2-1: AAL-LPU Capabilities** + +| Capability | +|--------------------------------------------------------------------------------------------------| +| The AAL Profile(s) supported by this instance of the AAL-LPU, AAL_PUSCH_FEC or AAL_PDSCH_FEC. | +| Maximum number of AAL-LPU Queues Supported by this instance of the AAL-LPU | +| Number of AAL-LPU Queues Currently configured by this instance of the AAL-LPU | +| AAL-LPU State (started, stop) | +| AAL-LPU Queue Size restrictions if any. | +| AAL-LPU maximum priority if the AAL-LPU supports Queues Priorities. | +| Whether the AAL-LPU supports per-queue interrupts (If not supported poll mode must be supported) | +| Any memory alignment requirements on input and output buffers to the AAL-LPU | + +External Memory sizes available to the LPU, in the case of HARQ for AAL\_PUSCH\_FEC profile this would be the size of the HARQ memory available to store HARQ buffers in. This size shall be reported in kB. + +Any AAL Profile Specific capabilities that are supported as defined in Table 6.1.1.1-1: and + +### 5.2.3 Setup and Allocate AAL LPU Queues + +The AALi shall provide an interface to setup and allocate AAL-LPU Queues. + +### 5.2.4 Configure AAL-LPU Queues + +The AALi shall provide an interface to configure the AAL-LPU's queues setup from section 5.2.3. The AAL-LPU Queue configuration API shall support the configurations defined in Table 5.2.4-1. + +**Table 5.2.4-1: AAL-LPU Queue Configuration** + +| Queue Configuration | +|-------------------------------------------------------------------------------------| +| The size of the queue to configure. This is the number of entries a queue can hold. | +| The priority of the queue if priority is supported. | +| AAL Profile that is supported, either AAL_PUSCH_FEC or AAL_PDSCH_FEC | + +## 5.3 AAL-LPU Management and AAL-LPU Queue management + +As per sequence diagram in Clause 5.3.2 in [8] the below list defines the high-level AAL-LPU and AAL-LPU Queue management interfaces shall be supported by an AAL Implementation. + +- Start AAL-LPU +- AAL-LPU Queue Start +- AAL-LPU Queue Stop +- AAL-LPU Stop +- Close AAL-LPU + +## 5.4. AAL Statistics + +The AALi shall provide an interface to retrieve statistics from an AAL-LPU Device and/or AAL-LPU Queue. The statistics shall include error counts. In addition, the AAL Implementation shall provide an interface to reset statistic counters in the AAL-LPU. + +# --- 6 AAL Profile Specifications + +## 6.1 Profile Specifications Overview + +This section contains information for each supported AAL profile. A profile may provide several APIs for specific profile configuration in addition to the general AAL configuration APIs. Profile specific configuration shall be applied on a per queue basis and only for functionality that cannot be changed at run time. Each profile shall define a capabilities list that will be used to define the operations supported by the AAL-LPU. + +### 6.1.1 Operation Representation + +Operations offloaded to the AAL-LPU are represented by a single operation context that shall include all necessary information required by the AAL Implementation to process the operation. + +The operation context defines the operation type as supported by the AAL Profile. It includes an operation status, a reference to the operation specific data, which can vary in size and content depending on the operation/profile being provisioned. Application software is responsible for specifying all the operation-specific fields that are then used by the AAL-LPU to process the requested operation. + +Scheduling of AAL operations on an application data path is performed using a burst oriented asynchronous API set. A queue on an AAL-LPU accepts a burst of operations (1 to N number of operations) using enqueue API. The enqueue API will place the operations to be processed on the AAL-LPU's hardware input. The dequeue API will retrieve any processed operations available from the queue on the AAL-LPU. + +### 6.1.2 Profile Capabilities + +Each Profile has a set of capabilities which capture the functions supported by each implementation. This includes optional features such as interrupts and debug interfaces. The AAL shall provide an API to report the capabilities of the underlying AAL implementation as per clause 5.2.2. + +### 6.1.3 Memory Management + +The AAL Implementation shall provide any profile specific memory management (examples allocate and free memory) as required by the AAL Implementation. + +## 6.2 O-DU AAL PDSCH FEC Profile Specification + +As per O-RAN AAL GAnP document [7] the PDSCH FEC Profile shall support + +- CRC Generation +- LDPC Encoding +- PDSCH Rate Matching + +### 6.2.1 AAL FEC PDSCH Profile Capabilities + +The AAL FEC PDSCH Profile interface shall support operations on both a code block (CB) and a transport block (TB) basis. + +An operation can be performed on one CB at a time "CB-mode". An operation can be performed on one or multiple CBs that logically belong to a TB "TB-mode". The input data is the CB or TB input to the encoder. The output data is the ratematched CB or TB data. + +The input and output buffers shall be allocated by the application according to 6.1.3. + +The input buffer shall contain the input code block or transport block data the operation is to be performed on. + +The output buffer is mandatory and is the encoded CB(s). In CB-mode it contains the encoded CB of size $e$ (E in 3GPP TS 38.212 section 6.2.5). In TB-mode it contains multiple contiguous encoded CBs of size $e_a$ or $e_b$ . The output buffer is allocated by the application with enough room for the output data. + +The following modes of operation shall be supported: + +CB-mode: one CB (with CRC24B appended to the output buffer if required) + +CB-mode: one CB making up one TB (with CRC16 or CRC24A appended to the output buffer if required) + +TB-mode: one or more CB of a partial TB (with CRC24B(s) appended to the output buffer if required) + +TB-mode: one or more CB of a complete TB (with CRC16, CRC24A and CRC24B(s) appended to the output buffer if required) + +The AAL\_PDSCH\_FEC Profile shall list the CRC's supported in its capabilities. The AAL Implementation of the AAL\_PDSCH\_FEC Profile shall provide the flexibility for the application to configure the operation in CB-mode with application selected CRC type and TB-mode with application selected CRC type. + +In CB-mode an application can select whether CRC24A is appended to the CB or not. If configured not to append CRC24A then the application not the AAL Implementation, shall calculate and append CRC24A before calling AAL. The input data length is inclusive of CRC24A/B where present and is equal to the code block size $K'$ . Note that code block length will always be a multiple of 8 and it is assumed that there are 8 bits packed into each byte. + +In TB-mode, the input data length shall equal the total size of the CBs inclusive of any CRC24A and CRC24B.. + +In the case of a partial TB the AAL Application shall provide the index of the first CB in the group of CBs and the number of CBs in the group.. + +The number of CBs in the group should not be confused with $c$ , the total number of CBs in the full TB ( $C$ as per 3GPP TS 38.212 section 5.2.2). + +When using CB-mode, concatenation of the output code blocks into a transport block, is not performed by the AAL Implementation. + +The AAL\_PDSCH\_FEC Profile capabilities shall be reported to the application as per Table 5.2.2-1: AAL-LPU Capabilities . The AAL\_PDSCH\_FEC Profile capabilities are defined in Table 6.1.1.1-1: AAL\_PDSCH\_FEC Profile Capabilities, these capabilities shall be reported to the application and may not be implemented by the AALi implementation. BG: a bit unclear what's being specified- the application function of AAL functions here. + +#### 6.1.1.1 Summary of AAL\_PDSCH\_FEC Profile capabilities + +Table 6.1.1.1-1 lists the AAL\_PDSCH\_FEC profile capabilities that shall be reported to the application. + +**Should be silent here. Table 6.1.1.1-1: AAL\_PDSCH\_FEC Profile Capabilities** + +| Capabilities | +|------------------------------------------------------------------| +| Whether interrupts are supported by this AAL-LPU | +| What CRCs are supported (CRC24A, CRC24B, CRC16) | +| Support for input Scatter Gather | +| Support for concatenation of non-byte-aligned output code blocks | + +### 6.2.2 AAL PDSCH FEC Profile Operations + +The following parameters shall be supported by the AAL Implementation when offloading operations. + +**Table 6.2.2-1: AAL\_PDSCH\_FEC Profile parameters** + +| Parameters | +|------------------------------------------------------------------------------| +| The input TB or CB data. | +| The encoded rate matched TB or CB output buffer. | +| Capabilities selection for CRC Types required to be applied | +| Rate matching redundancy version [3GPP TS38.212, section 5.4.2] | +| LDPC Base graph 1 or LDPC Base graph 2. [3GPP TS38.212, section 5.2.2] | +| Zc, LDPC lifting size. [3GPP TS38.212, section 5.2.2] | +| Ncb, length of the circular buffer in bits. [3GPP TS38.212, section 5.4.2.1] | +| Qm, modulation order {2,4,6,8}. [3GPP TS38.212, section 5.4.2.2] | +| Number of Filler bits, n_filler = K – K' [3GPP TS38.212 section 5.2.2] | +| Whether transport block or code block applies to this operation. | + +#### 6.2.2.1 CB-Mode Parameters + +When using code block mode the following additional parameters shall be supported by the AALi implementation + +**Table 6.2.2.1-1: CB-mode parameters** + +| Parameters | +|-------------------------------------------------------------------------| +| E, length after rate matching in bits. [3GPP TS38.212, section 5.4.2.1] | + +#### 6.2.2.2 TB-Mode Parameters + +**Table 6.2.2.2-1: TB-mode parameters** + +| Description | +|----------------------------------------------------------------------------------------| +| Ea, length after rate matching in bits, $r < cab$ . [3GPP TS38.212, section 5.4.2.1] | +| Eb, length after rate matching in bits, $r \ge cab$ . [3GPP TS38.212, section 5.4.2.1] | +| The total number of CBs in the TB or partial TB | +| The index of the first CB in the inbound mbuf data, default is 0 | +| cab, The number of CBs that use Ea before switching to Eb, [0:255] | + +## 6.3 O-DU AAL PUSCH FEC Profile Specification + +This section defines the AAL PUSCH FEC Profile specification. As per O-RAN AAL GANP document [7] the AAL\_PUSCH\_FEC Profile shall support the following functions + +- PUSCH Rate De-matching +- LDPC Decoder +- CRC Check + +NOTE: the AAL\_PUSCH\_FEC Profile only supports PUSCH Forward Error Correction. It shall not include support for PUSCH UCI + +### 6.3.1 AAL FEC PUSCH Profile Capabilities + +The decode operations are invoked through enqueue and dequeue functions. The operation context defines the parameters used to configure the operation to be accelerated. These parameters are defined in 6.3.2. + +The input and output buffers shall be allocated by the application according to 6.1.3. The input buffer shall contain the encoded CB data to be decoded and is the Virtual Circular Buffer data stream with null padding. Each byte in the input circular buffer is the LLR value of each bit of the original CB. + +The output buffer shall contain the hard\_output which is the decoded CBs of size $K'$ (CRC24A/B or CRC16 is the last 24bit or 16bits in each decoded CB. The AAL Implementation shall give the option to drop the CRC. Where CRC Drop is set then the CRC will not be present at the end of the buffer). In transport block mode the hard\_output will contain the decoded transport block. + +The AAL Implementation may support the optional soft output buffer which is an LLR rate matched output of size $e$ (this is $E$ as per 3GPP TS 38.212 section 6.2.5). + +The AAL Implementation may support optional harq input buffer which is a buffer with the input to the HARQ combination function. If the AAL-LPU supports internal memory capability and is enabled, then the HARQ shall be stored in the AAL-LPU internal memory and shall not visible to the application. + +The AAL Implementation may support the optional HARQ Combined output which is a buffer for the output of the HARQ combination function of the AAL-LPU. If the AAL-LPU supports internal memory capability and is enabled, then the HARQ is stored in memory internal to the AAL-LPU and not visible to application. + +As with the AAL PDSCH FEC Profile, the decode interface works on both a code block (CB) and a transport block (TB) basis. + +The following modes of operation shall be supported: + +CB-mode: one CB (CRC24B if required) + +CB-mode: one CB making up one TB (CRC16 or CRC24A if required) + +TB-mode: one or more CB making up a partial TB (CRC24B(s) if required) + +TB-mode: one or more CB making up a complete TB (CRC16, CRC24A and CRC24B(s) if required) + +The buffer length is inclusive of CRC24A/B where present and is equal the code block size $K'$ . + +The first CB Virtual Circular Buffer (VCB) index is given by $r$ but the number of the remaining CB VCBs shall be calculated by the AAL implementation. + +The input buffer length shall equal the total size of the CBs inclusive of any CRC24A and CRC24B in case they were appended by the application. + +#### 6.3.1.1 LLR Compression + +The AAL PUSCH FEC Profile may support compression of the LLR bits used for the HARQ data. This improves PCIE memory bandwidth and memory storage. LLR compression support shall be reported through the AAL to the application.. + +#### 6.3.1.2 Summary of AAL\_PUSCH\_FEC Profile capabilities + +Table 6.3.1.2-1 lists the AAL\_PUSCH\_FEC profile capabilities that shall be reported to the application. + +###### **BG: be silent or be specific- which others or say nothing. Table 6.3.1.2-1: AAL\_PUSCH\_FEC Profile capabilities** + +| Capabilities | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| LLR size in bits. Each LLR is a two's complement number. This can be AAL-LPU implementation specific. | +| LLR numbers of decimals bit for arithmetic representation. This can be AAL-LPU implementation specific. | +| Type of CRC Support (CRC24A, CRC24B, CRC16) | +| CRC Dropping supported and configurable | +| HARQ Combine input enabling and disabling | +| HARQ Combine output enabling and disabling | +| Soft Output enabling and disabling | +| LDPC Iteration stop enabling and disabling, that is stopping on successful decode (syndrome check) | +| Whether Scatter Gather of input buffers is supported | +| Support for concatenation of non byte aligned output code blocks | +| If an AAL-LPU supports input/output HARQ compression. Compressed would be packed 6bit LLRs as opposed to 6bit LLR per byte | +| If an AAL-LPU supports input LLR compression. Packed 6bit LLR inputs. | +| If an AAL-LPU supports HARQ input to/from AAL-LPU's internal memory. | +| If an AAL-LPU supports HARQ output to/from AAL-LPU's internal memory. | +| If an AAL-LPU includes LLR filler bits in the circular buffer for HARQ memory. If not enabled, it is assumed the filler are not in HARQ memory and handled directly by the LDPC decoder. | + +### 6.3.2 AAL PUSCH FEC Profile Operations + +The following parameters shall be supported by the AAL Implementation when offloading operations. + +**Table 6.3.2-1: AAL\_PUSCH\_FEC Profile Parameters** + +| Description | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| The input Virtual Circular Buffer for this code block, one LLR per bit of the original CB or TB. See <b>Error! Reference source not found.</b> | +| The hard decisions buffer for the decoded output, size K' for each CB when in code block mode, otherwise TB or partial TB output. See <b>Error! Reference source not found.</b> | +| The soft LLR output LLR stream buffer - optional | +| The HARQ combined LLR stream input buffer - optional. See <b>Error! Reference source not found.</b> | +| The HARQ combined LLR stream output buffer - optional. See <b>Error! Reference source not found.</b> | +| Optional capabilities configuration as per | +| Rate matching redundancy version [3GPP TS38.212, section 5.4.2.1] | +| The maximum number of iterations to perform in decoding CB in this operation - input | +| The number of iterations that were performed in decoding CB in this decode operation - output | + +| | +|------------------------------------------------------------------------------| +| LDPC Base graph 1 or 2. [3GPP TS38.212, section 5.2.2] | +| Zc, LDPC lifting size. [3GPP TS38.212, section 5.2.2] | +| Ncb, length of the circular buffer in bits. [3GPP TS38.212, section 5.4.2.1] | +| Qm, modulation order {1,2,4,6,8}. [3GPP TS38.212, section 5.4.2.2] | +| Number of Filler bits, n_filler = K-K' [3GPP TS38.212 section 5.2.2] | +| Code Block or Transport Block | + +#### 6.3.2.1 CB-Mode Parameters + +When CB-Mode is used, the following additional parameters shall be supported + +**Table 6.3.2.1-1: AAL\_PUSCH\_FEC Profile CB-Mode Parameters** + +| Description | +|-------------------------------------------------------------------------------------------| +| Rate matching output sequence length in bits or LLRs.<br>[3GPP TS38.212, section 5.4.2.1] | + +#### 6.3.2.2 TB-Mode Parameters + +When TB-Mode is used, the following additional parameters shall be supported + +**Table 6.3.2.2-1: AAL\_PUSCH\_FEC Profile TB-Mode Parameters** + +| Description | +|------------------------------------------------------------------------------------| +| Ea, length after rate matching in bits, r < cab. [3GPP TS38.212, section 5.4.2.1] | +| Eb, length after rate matching in bits, r >= cab. [3GPP TS38.212, section 5.4.2.1] | +| The total number of CBs in the TB or partial TB | +| The index of the first CB in the inbound mbuf data, default is 0 | +| cab, The number of CBs that use Ea before switching to Eb, [0:255] | + +## 6.4 AAL Profile API Definitions + +O-RAN and the O-RAN Software Community[7] has published a normative definition of the AAL FEC API's. The AAL FEC API definitions are based on the WG6 AAL FEC profile requirements in [7] and this document. Refer to AAL Repository [9] in the OSC for APIs description details. This current version uses the git tag version oran\_e\_maintenance\_release\_v1.0 + +### 6.4.1 O-RAN AAL FEC API Terminology + +The O-RAN AAL FEC API definition is based on DPDK, as such the naming convention and coding styles follow DPDK guidelines [i2]. This section gives an overview of the DPDK terminology mapping to the profile specification[9]. + +| AAL FEC Profile Terminology | AAL FEC API Terminology | +|-----------------------------|-------------------------| +|-----------------------------|-------------------------| + +| | | +|---------------|-----------------------| +| AAL-LPU | Device ID | +| AAL Queue | Queue ID | +| AAL_PDSCH_FEC | RTE_BBDEV_OP_LDPC_ENC | +| AAL_PUSCH_FEC | RTE_BBDEV_OP_LDPC_DEC | + +#### 6.4.1.1 Configuration and Management + +The configuration and management interfaces are defined in `rte_bbdev.h` in the O-RAN AAL Specification repo [9] + +#### 6.4.1.2 FEC Profile Operations + +The AAL profile operations are defined in `rte_bbdev_op.h` in the the O-RAN AAL Specification repo [9]. The mapping of profile definition to the API implementation for the AAL\_PDSCH\_FEC Profile parameters as defined previously in Table 6.2.2-1 is demonstrated below in + +| Parameters from Table 6.2.2-1: 6.2.2-1 | DPDK <code>rte_bbdev_op_ldpc_enc</code> structure data field | +|-----------------------------------------------------------------------------------|------------------------------------------------------------------------------------------| +| The input TB or CB data. | <code>struct rte_bbdev_op_data input</code> | +| The encoded rate matched TB or CB output buffer. | <code>struct rte_bbdev_op_data output</code> | +| Capabilities selection for CRC Types required to be applied | <code>/** Flags from rte_bbdev_op_ldpcenc_flag_bitmasks */<br/>uint32_t op_flags;</code> | +| Rate matching redundancy version [3GPP TS38.212, section 5.4.2] | <code>uint8_t rv_index;</code> | +| LDPC Base graph 1 or LDPC Base graph 2. [3GPP TS38.212, section 5.2.2] | <code>uint8_t basegraph;</code> | +| Zc, LDPC lifting size. [3GPP TS38.212, section 5.2.2] | <code>uint16_t z_c;</code> | +| Ncb, length of the circular buffer in bits. [3GPP TS38.212, section 5.4.2.1] | <code>uint16_t n_cb;</code> | +| Qm, modulation order {2,4,6,8}. [3GPP TS38.212, section 5.4.2.2] | <code>uint8_t q_m;</code> | +| Number of Filler bits, $n_{\text{filler}} = K - K'$ [3GPP TS38.212 section 5.2.2] | <code>uint16_t n_filler;</code> | +| Whether transport block or code block applies to this operation. | <code>/** [0 - TB : 1 - CB] */<br/>uint8_t code_block_mode;</code> | + +# Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|--------------------------------------------------------------------------------------------------| +| 2021.05.06 | 00.00.01 | Initial draft of specification - Overview, Configuration and management, profile specifications. | +| 2021.07.06 | 00.00.02 | Updates to PDSCH FEC Profile to include code block concatenation. | +| 2022.03.24 | 02.00.00 | Added Reference to normative stage 3 implementation published in O-RAN Software Community. | +| 2022.06.17 | 03.00.00 | Added support for CBGTI | +| 2024.04.26 | 03.00.01 | Updated to ETSI template, removed and updated references. Clarified text and verbal forms. | +| 2024.07.29 | 03.00.02 | Editorial change to remove stray comment. | +| 2024.07.31 | 04.00.00 | Published as version 4 | \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/09972ba5e7e651a90b65097e7b0655d7_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/09972ba5e7e651a90b65097e7b0655d7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d8666988fe8ab25f2de81baee1c11d9626b8aebf --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/09972ba5e7e651a90b65097e7b0655d7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e0f867f9021fdfb91708a41b6dceaa9977e9897b080f71ae4df6927ef93febc +size 43444 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/0a08e5ee57dd048c63e2e5be280397a1_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/0a08e5ee57dd048c63e2e5be280397a1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..49d261f81da05b9c8b5b3fc5079808a495333d3e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/0a08e5ee57dd048c63e2e5be280397a1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aec6f53cb8fed9afaaf67791e76366a058a0e9dd36c6c2479f858e91380fe1c0 +size 98479 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/0e312e4373cf861a6947d7e29becdeea_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/0e312e4373cf861a6947d7e29becdeea_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d50c0d9bb1670d5b0b6722b26a6e090204ff91b5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/0e312e4373cf861a6947d7e29becdeea_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f0bf08d973b3e241a2fe6fa4091ce7ac1c44e35d6676cf7335017f397b720a7f +size 4062 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/1029e6c09fa96e2e419912415d9ff243_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/1029e6c09fa96e2e419912415d9ff243_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dab31ef51cfca64cfe8ed95dc2d1717031061238 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/1029e6c09fa96e2e419912415d9ff243_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a12f4f09aa78e862b18a224c1045ee2c24582eb2f0d71ae98669d73bdeee4694 +size 75592 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/14878831df8436494a0bcf013fac14cd_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/14878831df8436494a0bcf013fac14cd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3620b84cb7aca2d2fdd8d3ce13620ba462462d59 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/14878831df8436494a0bcf013fac14cd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6e9ce6b48d205ed2f609a5ab540e07280f9e28525cd21cbcef11ed69afecc52b +size 40440 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/202374af27333eb909b509122900acd0_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/202374af27333eb909b509122900acd0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c49023006ab785f7fbd38c016b1b7a8e0ec7f2f0 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/202374af27333eb909b509122900acd0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:216d7861c1291fd76ead0309144aac7a9cd7cd86a1eedb3c9d4a62fb9ae8bcc2 +size 57408 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/2a2edfb117f8a1aadf8e85b3e66e7af7_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/2a2edfb117f8a1aadf8e85b3e66e7af7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e45ed9a7032a9a5959d347a6dc845f42e6d652f3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/2a2edfb117f8a1aadf8e85b3e66e7af7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c4a78c5aa6690cd79b0ae422185c47a6feb946905ef92d6db580d96b699f7b1a +size 3954 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/3f0d679c36471316685b4876ee7bb79d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/3f0d679c36471316685b4876ee7bb79d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bcc79c9759812598236ef7b8fdb7eee26ed5de42 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/3f0d679c36471316685b4876ee7bb79d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4ed6f11a7970eefb85da46af155b3efa96e0cb3f19a255e72386d19265ed70cd +size 194417 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/467037c727838a5ac6cbaebd45a5c64d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/467037c727838a5ac6cbaebd45a5c64d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..71672c9dbb573a0af768d385dc036ac89733d853 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/467037c727838a5ac6cbaebd45a5c64d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d80c4941b2db8691b7f5983616fd8e94864feb2dd75a0b5f45482725f2e8e38c +size 51153 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/469425e9d76750c8b4788066064a5492_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/469425e9d76750c8b4788066064a5492_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ec54d37996b605033da6bd6887c0181883a0f9bc --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/469425e9d76750c8b4788066064a5492_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:96fbba4f05d0ffd58b46409d442eabc1c56f0126665cd2ef9197cd1b46f1d2f7 +size 70443 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/4fa46513edc2038121073b5baea209d7_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/4fa46513edc2038121073b5baea209d7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..06233c1a6fb5edf2964543ba970a1c44788acc02 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/4fa46513edc2038121073b5baea209d7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b9c432ad428b4f95de08d0c88e7ceb7ea2c62c3fb91b644a0505332c58c380c4 +size 68122 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/543a4f9019f760c34a5c5e5ca701ebb7_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/543a4f9019f760c34a5c5e5ca701ebb7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..29ce4d0cea8aecb3a3f5004b02061ec89a012fd0 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/543a4f9019f760c34a5c5e5ca701ebb7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:affe5c9f6f9b87d7aed926563594fcdb84168a9dd5cd5f3979df1556f9014bd6 +size 34180 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/5c89815011cd46b8d05dbb08bd220113_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/5c89815011cd46b8d05dbb08bd220113_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..79301b0245a9fd699ae4f3fffe3fa870d096b702 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/5c89815011cd46b8d05dbb08bd220113_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e861cdfea4311e7cbe97ed8ea2b3f6bad3e1547f9d6742f9e6799a04806c3306 +size 3983 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/63547b8aeefc842f9414426810b13a2c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/63547b8aeefc842f9414426810b13a2c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d8c6f2272827de6f12f5f0c9d9f0832e781fe2f1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/63547b8aeefc842f9414426810b13a2c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:97e91511d6a0c6cb6d1df9ef54ad8726e9fb9399604980fda4ce828db33c29e5 +size 143384 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/72687c496893ef673bb5cf9bd52fd12e_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/72687c496893ef673bb5cf9bd52fd12e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e068db9da8fda000ce87dcb66f447a5461f05e69 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/72687c496893ef673bb5cf9bd52fd12e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7fff5aad1b70b094393469b7035bced32fb5641f706f9f6597a9e76fb1e6b6a2 +size 110991 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/72883f24fcc91acb33583fd1660dd8d3_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/72883f24fcc91acb33583fd1660dd8d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cc0698ff1009a481a14ecd6c7a3f761c3f1aaa81 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/72883f24fcc91acb33583fd1660dd8d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3fd59ac8381c24ec9ef1c3303da11a428afbf3ecc441fb94844d793c951b8c70 +size 3965 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/841d85cf5bc0c6f05fc5ea8b11311dca_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/841d85cf5bc0c6f05fc5ea8b11311dca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b272d3c7449b3dcbbf047f5b3fafcaea4e6ac61a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/841d85cf5bc0c6f05fc5ea8b11311dca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:898bd430c5b9476a4f9ef21f7f1ad1966609596e5b58b3054022d1949bc92241 +size 72319 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/84cc0f07596f9e7b695d58bca267c3bf_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/84cc0f07596f9e7b695d58bca267c3bf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..67fd4ba050aee5ff779c436b7bc18b6946c61a68 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/84cc0f07596f9e7b695d58bca267c3bf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:73ca38926d5ba63a90bdd69e3e0b6b3f7df6d9efaef2f68f253daa9ffbb7e962 +size 4074 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/87d40fffb030b8d98b03ac2f64781a1d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/87d40fffb030b8d98b03ac2f64781a1d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a00d022bf652dd44a4a26a57d94d314a21468c28 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/87d40fffb030b8d98b03ac2f64781a1d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:21a0429f0d846c79ac586f8d5c3d17c106d00c6a97ebdfe0e0c4b6a06b053ca5 +size 36918 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/8fc34bc59ac1849b848a737b2cd379e5_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/8fc34bc59ac1849b848a737b2cd379e5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..965f2efd38518ca7cb18d55ffb97bb14692451cc --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/8fc34bc59ac1849b848a737b2cd379e5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2af8278f884892b73e751868d9b8ee1c65e162709acc1cd9753fec2b040ba6d4 +size 183416 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/91bf418f53337d71e80fdb42ab0776c5_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/91bf418f53337d71e80fdb42ab0776c5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b5fe871e1c7d97c473ef773e8987f05d6e387552 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/91bf418f53337d71e80fdb42ab0776c5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:964facf1c38ff5d500f360d276c276464f36c0d072033adccfe82bb31fdea0b5 +size 185996 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/959ae85c474b89c55a65fc5a096c81bc_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/959ae85c474b89c55a65fc5a096c81bc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9c6ad74b3c3f01a4e278c2771231bd8a2dec2346 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/959ae85c474b89c55a65fc5a096c81bc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b59b68b79e86acbf773f129036be8f9ef9b8801083775ee0d63e7b56121707eb +size 159284 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/98de20f3b94513c9912b691e57d5cb30_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/98de20f3b94513c9912b691e57d5cb30_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d41a8ef736a3ac8766ed4160716fd64a76a33f23 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/98de20f3b94513c9912b691e57d5cb30_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1d6ab29d8e66e0d7d2a8730f20f084504aa9d2edc93cdd0ede3ea38fbe339c2c +size 146040 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/99064b33e8d947d1be906d4de4bcf6ce_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/99064b33e8d947d1be906d4de4bcf6ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0112472affcd776642dedbb9340962670c07ab95 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/99064b33e8d947d1be906d4de4bcf6ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9671abea87fcf8d6050d85c34d1c9e6e9a40785873aa984773ffbc285603148a +size 18702 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/acde9b5dade7b057db6eba9b3dd8f67f_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/acde9b5dade7b057db6eba9b3dd8f67f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..13dc873a88b49937b9dafab3e8fe36fcd0a25518 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/acde9b5dade7b057db6eba9b3dd8f67f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:737372ee7294399839b13dfcfd821292f5139d2424544a8a059e4fce107d94b2 +size 3954 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/ad450497d134f55019be57c4ab18f50a_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/ad450497d134f55019be57c4ab18f50a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b79cf67a58d80d1a17f8abbd997fe13062e469c3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/ad450497d134f55019be57c4ab18f50a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0874fdf46181d9b8777e6572bc4d8da4463e3597401324afd2a6769b890ea6ed +size 4063 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/ae3182083ec020f8c0e7568c3096ef28_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/ae3182083ec020f8c0e7568c3096ef28_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e3d5788e3744fe25687e86757f388a684e163096 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/ae3182083ec020f8c0e7568c3096ef28_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1e55cf7ea828e380926a584a1da8541e9d227a8096986b5f0b89bb0f5428e439 +size 3897 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/afb680ec82911ef602424f411ad6c47c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/afb680ec82911ef602424f411ad6c47c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..566d55f713b21231917c38738fc20fe23d5f4267 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/afb680ec82911ef602424f411ad6c47c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b63578d487d0d9d0a9bf58e5fd9ee2fc0f6761a372a4dca232062aa68bdb3144 +size 192325 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/b0cd9740db67a81670c03ac5c51b29fa_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/b0cd9740db67a81670c03ac5c51b29fa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..45a39ef03943c99521014acae5127fc467f450de --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/b0cd9740db67a81670c03ac5c51b29fa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32660833f4aa7ec8972ba4e879b8010b3c8e8c1ac7b9ac3f7c01a3763eb75515 +size 3952 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/d0a0a0ef6e5ec73f3ccd1bbd159fbc2e_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/d0a0a0ef6e5ec73f3ccd1bbd159fbc2e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1a001c2e5e67b165c0ef4bb970fc0e474dfa212 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/d0a0a0ef6e5ec73f3ccd1bbd159fbc2e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:572d044f10af31d89352a8eab2536eb9c6fd93006ca10b7b5f0372a54cb09f7b +size 3988 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/e0fc3d05ed6481a00ad3f8c5bac0fd76_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/e0fc3d05ed6481a00ad3f8c5bac0fd76_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b0d622acf92a942352bf26bb7b9a280d6ad7cc96 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/e0fc3d05ed6481a00ad3f8c5bac0fd76_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:725be718ccaac1909f6ec41e356cce0c887b630227535614373e68e3aaa18119 +size 4009 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/e176807f1e086f55c30bf9e34817f789_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/e176807f1e086f55c30bf9e34817f789_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..93963993b449c71c1e4e3dbae2d35c2f05574d46 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/e176807f1e086f55c30bf9e34817f789_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:711e4530a30ba0415e79666b18572c1529a817991c580b696380420aef202e22 +size 80149 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/efcbd668a18701022e58bc5675b04af1_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/efcbd668a18701022e58bc5675b04af1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6ef0d3ce206114806512b39d22e8605c2c0da12d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/efcbd668a18701022e58bc5675b04af1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e0eb179619502b162628c2147e56a4d0730573d50a83efb10eb0395c46718a7a +size 3983 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/f14da42d751affbd65dcdd7a4b6c1c60_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/f14da42d751affbd65dcdd7a4b6c1c60_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8ca9bc0f330ceaf3fba835dabc82d2efecb09875 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/f14da42d751affbd65dcdd7a4b6c1c60_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:99ad63e4cd88ec5a570cb37a344df3872f22946ecbd04e07701b8eb48b2528b9 +size 4516 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/f170ee243217290be8eaaba5cddd129c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/f170ee243217290be8eaaba5cddd129c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0d2b2a76854c4d7c15ddb2aedf13dc96945b6a19 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/f170ee243217290be8eaaba5cddd129c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:11fe0ed37b3742177d497d848cbfe4c16089376d7fa159830e0d2f24a14df45a +size 3952 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/f7819f03ca6e1b62a574ade96efc5497_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/f7819f03ca6e1b62a574ade96efc5497_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cecbef117263c9603883b1f09abc384917228b68 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/f7819f03ca6e1b62a574ade96efc5497_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3b97f6b2bef792867315eeb0f8adbcc6f1b44fe4d08cde6ee4a0e7c381b0fc25 +size 3957 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/fcfa2af3bdb7fc45e39c3b6f0b17bc94_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/fcfa2af3bdb7fc45e39c3b6f0b17bc94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9a91df1a55ded9217ff7bd7a2420c4f14077a295 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/fcfa2af3bdb7fc45e39c3b6f0b17bc94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a013551def5c879c4fd63a3df8925825362e7724eb842ad2357d3f13f6b116f9 +size 3990 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/fdedafdcba7cdfd0ae12e7cde99a4b09_img.jpg b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/fdedafdcba7cdfd0ae12e7cde99a4b09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3b7ea9decf94c219ab432753b231a5d27ca34658 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/fdedafdcba7cdfd0ae12e7cde99a4b09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c03b9b73f2413a967ab83f2c13fe73eb1f96e4c1526290a5acc2050ab47d737d +size 3993 diff --git a/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/raw.md b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..45c97c8b3aac4d14f07cca6c4402069f3279b38d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00/raw.md @@ -0,0 +1,4474 @@ + + +# **O-RAN Working Group 6 (Cloudification and Orchestration Workgroup) Acceleration Abstraction Layer Common API** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|-------------------------------------------------------------------------------|----| +| Chapter 1 Introductory Material ..... | 4 | +| 1.1 Scope 4 ..... | | +| 1.2 References ..... | 4 | +| 1.3 Definitions and Abbreviations ..... | 5 | +| 1.3.1 Definitions ..... | 5 | +| 1.3.2 Abbreviations ..... | 5 | +| Chapter 2 Overview ..... | 6 | +| 2.1 General ..... | 6 | +| 2.2 Document Structure ..... | 6 | +| Chapter 3 AAL Common requirements and Object Model ..... | 7 | +| 3.1 AALI-C Mgmt Requirements ..... | 7 | +| 3.1.1 Functional requirements for the HAM ..... | 8 | +| 3.2 AALI-C App Requirements ..... | 10 | +| 3.2.1 AALI-C-APP Transport Abstraction Requirements and Operations ..... | 10 | +| 3.3 AAL Information Model ..... | 11 | +| 3.3.1 Overview ..... | 11 | +| 3.3.2 AALI-C-Mgmt Information Model ..... | 12 | +| 3.3.2.1 Imported and associated information entities ..... | 12 | +| 3.3.2.1.2 Associated information entities and local labels ..... | 12 | +| 3.3.2.2 Class Diagram ..... | 12 | +| 3.3.2.3 Class Definitions ..... | 14 | +| 3.3.3 AALI-C-App Information Model ..... | 25 | +| 3.3.3.1 Imported and associated information entities ..... | 25 | +| 3.3.3.2 Class Diagram ..... | 25 | +| 3.3.3.3 Class Definitions ..... | 27 | +| 3.3.4 Naming convention and managed resource tags ..... | 29 | +| 3.3.4.1 API managed resources tags ..... | 29 | +| 3.3.4.2 API Naming Conventions ..... | 30 | +| 3.3.4.3 Model Conventions ..... | 30 | +| Chapter 4 AALI-C-Mgmt ..... | 30 | +| 4.1 AALI-C-Mgmt operations and events ..... | 30 | +| 4.2 AALI-C-Mgmt use case workflows ..... | 32 | +| 4.2.1 HW Accelerator installation/bootstrap use case workflow ..... | 32 | +| 4.2.1.1 Sequence Diagram ..... | 33 | +| 4.2.2 end-2-end Life Cycle Management use case workflow (Informational) ..... | 35 | +| 4.2.2.1 Sequence Diagram ..... | 37 | +| 4.2.3 HW Accelerator Manager (HAM) registration use case workflow ..... | 41 | +| 4.2.3.1 Sequence Diagram ..... | 42 | +| 4.3 AALI-C-Mgmt API details ..... | 43 | +| 4.3.1 Capabilities discovery and configuration ..... | 43 | +| 4.3.1.1 getAalHwAccelStatus ..... | 43 | +| 4.3.1.2 getAalLpuStatus ..... | 44 | +| 4.3.1.3 getAalAccelInfo ..... | 45 | +| 4.3.1.4 setAalAccelConfig ..... | 48 | +| 4.3.1.5 startAalLpu ..... | 51 | +| 4.3.1.6 stopAalLpu ..... | 52 | +| 4.3.1.7 Inventory Notifications ..... | 52 | +| 4.3.1.8 setAalAccelIdentifier ..... | 53 | +| 4.3.1.9 aalHamRegistrationNotification ..... | 54 | +| 4.3.2 Infrastructure Monitoring Service ..... | 55 | +| 4.3.2.1 Fault Service Operations ..... | 55 | +| 4.3.2.2 Fault Notifications ..... | 56 | +| Chapter 5 AALI-C-APP ..... | 60 | +| 5.1 AALI-C-App Identification & Representation ..... | 60 | + +| | | +|----------------------------------------------------------------------------------------|------------| +| 5.2 AALI-C-App operations and events ..... | 61 | +| 5.3 AALI-C-App Operations and Events Sequence and State Diagram ..... | 62 | +| 5.3.1 AALI-C-App State ..... | 62 | +| 5.3.2 AALI-C-App API Init Sequence ..... | 64 | +| 5.3.3 AALI-C-Transport API Sequence ..... | 66 | +| 5.3.3.1 Allocation of AAL Buffer(s) ..... | 66 | +| 5.3.3.2 Procedure for Buffer(s) Send and Receive ..... | 70 | +| 5.4 AALI-C-App API details ..... | 90 | +| 5.4.1 Capabilities discovery and configuration ..... | 90 | +| 5.4.1.1 initAal ..... | 90 | +| 5.4.1.2 cleanupAal ..... | 90 | +| 5.4.1.3 getAalLpuInfo ..... | 91 | +| 5.4.2 AALI-C-App Configuration Services ..... | 92 | +| 5.4.2.1 createAalProfileInstance ..... | 92 | +| 5.4.2.2 setAalProfileInstanceConfig ..... | 93 | +| 5.4.2.3 deleteAalProfileInstance ..... | 93 | +| 5.4.2.4 setAalProfileQueueConfig ..... | 94 | +| 5.4.2.5 getAalProfileQueueConfig ..... | 95 | +| 5.4.2.6 getAalProfileInstanceConfig ..... | 96 | +| 5.4.3 AALI-C-App Transport Operations ..... | 97 | +| 5.4.3.1 createBufferPool ..... | 97 | +| 5.4.3.2 allocBuffer ..... | 98 | +| 5.4.3.3 getBufferAddr ..... | 100 | +| 5.4.3.4 getBufferSize ..... | 100 | +| 5.4.3.5 sendBuffer ..... | 101 | +| 5.4.3.6 receiveBuffer ..... | 103 | +| 5.4.3.7 freeBuffer ..... | 104 | +| 5.4.3.8 destroyBufferPool ..... | 105 | +| 5.4.4 AALI-C-App Administrative Operations ..... | 105 | +| 5.4.4.1 startAalProfileInstance ..... | 105 | +| 5.4.4.2 stopAalProfileInstance ..... | 106 | +| 5.4.4.3 startAalProfileQueue ..... | 107 | +| 5.4.4.4 stopAalProfileQueue ..... | 107 | +| <b>Annex A (normative): Acceleration Capability Requirements .....</b> | <b>108</b> | +| A.1 Capability requirements used in the placement of an AAL Application to an AF ..... | 108 | + +# Chapter 1 Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e., technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit is included only in working versions of the document indicating incremental changes during the editing process. + +The present document describes the functional requirements for the Hardware Accelerator Manager (HAM) and interface requirements for the AAL Common API (i.e., AALI-C-Mgmt and AALI-C-App interfaces). It also provides the specification of the AALI-C-Mgmt and AALI-C-App interfaces as well as the information elements exchanged over those interfaces. + +## 1.2 References + +- [1] 3GPP-TR-21.905: “Vocabulary for 3GPP Specifications”. +- [2] Void +- [3] O-RAN O-RAN.WG1.O-RAN-Architecture-Description +- [4] O-RAN O2 Interface General Aspects and Principles +- [5] O-RAN Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN +- [6] O-RAN O2ims Interface Specification +- [7] O-RAN Acceleration Abstraction Layer General Aspects and Principles +- [8] O-RAN Acceleration Abstraction Layer FEC Profiles +- [9] O-RAN Acceleration Abstraction Layer High-PHY Profiles +- [10] 3GPP TS 28.620: Telecommunication management; Fixed Mobile Convergence (FMC); Federated Network Information Model (FNIM); Umbrella Information Model (UIM)) +- [11] 3GPP TS 28.622: Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS) +- [12] 3GPP TS 32.156: " Model repertoire". +- [13] OAS 3.0 Specification: [OpenAPI Specification](#) +- [14] ITU-T X.731: Information Technology - Opens Systems Interconnection: State Management Function +- [15] IETF RFC 4122: “A Universally Unique IDentifier (UUID) URN Namespace” +- [16] IETF RFC 3986: IETF RFC 3986: "Uniform Resource Identifier (URI): Generic Syntax" + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in O-RAN Acceleration Abstraction Layer General Aspects and Principles [7] apply. + +UUID Universally Unique Identifier [15] + +URI Uniform Resource Identifier [16] + +### 1.3.2 Abbreviations + +For the purposes of the present document, the terms and definitions given in the O-RAN Acceleration Abstraction Layer General Aspects and Principles [7] apply. There are no additional abbreviations that are required aside from those in O-RAN Acceleration Abstraction Layer General Aspects and Principles [7]. + +# Chapter 2 Overview + +## 2.1 General + +The AAL General Aspects and Principles are described in [7] and the AAL architecture including the AAL interfaces are depicted in figure 4.2-1 in [7]. + +The set of interfaces used to expose AAL functionality is the following: + +1. AALI-C: AAL-Profile independent set of interfaces addressing all the independent aspects of the underlying AAL Implementation(s) within an O-Cloud platform. +2. AALI-P: A set of AAL-Profile specific interfaces dependent upon the AAL-Profile selected e.g., FEC. + +The AALI-P interfaces are specified in FEC[8] and High-PHY specifications [9]. + +Within the AALI-C interface set there are two interfaces: + +1. AALI-C-Mgmt: Interface used for common administrative operations, actions, and events between the O-Cloud IMS and the HW Accelerator Manager (HAM) for resources exposed by this interface. The IMS provides the O2 interface towards the SMO. The HAM exposes the AALI-C-Mgmt interface towards IMS. +2. AALI-C-App: Interface used for common operations/actions/events toward an AAL Application for resources exposed by this interface. These operations are between the AAL Implementation and the AAL Application (AAL-App). + +The present document specifies the list of AALI-C-Mgmt and AALI-C-App interface operations and events, description with input/outputs, information models, object models, state transition diagrams and requirements. + +NOTE: The scope of the interfaces specification in this document is between the O-Cloud IMS and the HAM as well as between the AAL Implementation and the AAL Application. Interactions between the IMS and SMO is part of the O2 IMS specification. [6] + +## 2.2 Document Structure + +This present document is structured as follows: + +Chapter 2 presents the overview and main purpose of this specification. + +Chapter 3 presents a list of requirements and object model. + +Chapter 4 presents the initialization and flow, operations and events associated with AALI-C-Mgmt. + +Chapter 5 presents the initialization and flow, operations and events associated with AALI-C-App. + +Annex A identifies the common acceleration capability requirements used for placing AFs. + +# Chapter 3 AAL Common requirements and Object Model + +## 3.1 AALI-C Mgmt Requirements + +The following table described the AAL-C-Mgmt interface requirements. The HAM shall support producing the AAL-C-Mgmt interface. The consumer of the interface is IMS. + +**Table 3.1-1: AALI-C-Mgmt Interface Requirements** + +| | Description | Additional Info (TBD) | +|---------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| +| [REQ-AALI-C-MGMT1a] | The AALI-C-Mgmt interface shall support unique identifiers for the HW Accelerators within an O-Cloud. | | +| [REQ-AALI-C-MGMT1b] | The AALI-C-Mgmt interface shall support unique identifiers for the AAL-LPUs within an O-Cloud. | | +| [REQ-AALI-C-MGMT2] | The AALI-C-Mgmt interface shall support querying inventory and capabilities information of the HW Accelerator. Inventory and capabilities information are related to the HW Accelerators and AAL-LPUs. | | +| [REQ-AALI-C-MGMT3] | VOID | | +| [REQ-AALI-C-MGMT4] | The AALI-C-Mgmt interface shall provide fault information for the HW Accelerator and AAL-LPUs. AALI-C-Mgmt interface shall support the autonomous sending of notification when a fault has been raised. AAL-C-Mgmt interface shall also be able to reply to on demand queries of faults (e.g., active faults). | | +| [REQ-AALI-C-MGMT5] | The AALI-C-Mgmt interface shall provide logs for the HW Accelerator and AAL-LPUs. Logs can be related to faults, debugging info etc. The AAL-C-Mgmt interface shall support operations like starting and stopping the logs collection and support the logs retrieval. | | +| [REQ-AALI-C-MGMT6] | AALI-C-Mgmt interface shall support providing performance information for the HW Accelerator and AAL-LPUs. The AAL-C-Mgmt interface shall support the autonomous sending of notification with PM info (e.g., periodically or due to an event). AAL-C-Mgmt interface shall also be able to reply to on demand queries for PM data. | | +| [REQ-AALI-C-MGMT7] | The AALI-C-Mgmt interface shall provide state management services for HW Accelerator and AAL-LPUs. Examples of state management operations are support querying the status and state information, autonomous notification of state changes, restart/reset HW Accelerator, Power Cycle HW Accelerator, Start AAL-LPU and Stop AAL-LPU. | | +| [REQ-AALI-C-MGMT8] | The AALI-C-Mgmt interface shall provide configuration management services. Examples of operations related to configuration management are the following: <ul style="list-style-type: none"> <li>• Configure the number of AAL-LPUs to be supported.</li> <li>• Configure the Profiles to be support on the AAL-LPUs.</li> <li>• Retrieve AAL-LPU capabilities.</li> <li>• Configure performance collection interval.</li> </ul> | | +| [REQ-AALI-C-MGMT9] | The AALI-C-Mgmt interface shall support the installation and upgrade of the HW Accelerator Drivers/FW. | | + +| | | | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| [REQ-AALI-C-MGMT10] | Void | | +| [REQ-AALI-C-MGMT11] | Void | | +| [REQ-AALI-C-MGMT12] | Void | | +| [REQ-AALI-C-MGMT13] | Void | | +| [REQ-AALI-C-MGMT14] | Void | | +| [REQ-AALI-C-MGMT15] | The AALI-C-Mgmt interface shall provide the ability to report the default values for attributes associated with AAL-Profiles that are supported by the HW Accelerator. | | +| [REQ-AALI-C-MGMT16] | The AALI-C-Mgmt interface shall report the capabilities associated with AAL-Profiles that are supported by the HW Accelerator. | | + +### 3.1.1 Functional requirements for the HAM + +The following tables describe functional requirements for the HAM. + +**Table 3.1.1-1: Functional requirements for HWA and LPUs lifecycle management** + +| | Description | +|-------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-HAM-LCM 1] | The HAM shall support the capability to expose inventory information and capabilities of the physical and logical partitioning of the hardware and software acceleration resources. | +| [REQ-HAM-LCM 2] | The HAM shall support the capability to discover the capabilities of the HW Accelerator(s). | +| [REQ-HAM-LCM 3] | The HAM shall support the capability to configure the HW Accelerator. See NOTE. | +| [REQ-HAM-LCM 4] | The HAM shall provide the capability to preserve HWA and AAL-LPU identifiers that are provided either by the IMS or the HAM and used in the AALI-C-Mgmt APIs: <ul style="list-style-type: none"> <li>HAM, O-Cloud node, HWA, AAL-LPU planned and unplanned restarts or reboots,</li> <li>HAM, O-Cloud node, HWA, AAL-LPU SW updates or configuration changes.</li> </ul> | +| NOTE: The configuration of the HW Accelerator Manager may include HW Accelerator resource assignment to AAL-LPUs. | | + +**Table 3.1.1-2: Functional requirements for faults and logs management** + +| | Description | +|----------------|-------------------------------------------------------------------------------------------------------------| +| [REQ-HAM-FM 1] | The HAM shall support the capability to expose fault information related to the HWA(s) it manages to IMS. | +| [REQ-HAM-FM 2] | The HAM shall support the capability to expose fault information related to the LPU(s) it manages to IMS. | +| [REQ-HAM-FM 3] | The HAM shall support the capability to expose logging information related to the HWA(s) it manages to IMS. | +| [REQ-HAM-FM 4] | The HAM shall support the capability to expose logging information related to the LPU(s) it manages to IMS. | + +**Table 3.1.1-3: Functional requirements for performance management** + +| | Description | +|-----------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-HAM-PM 1] | The HAM shall support the capability of performance management of HWAs. | +| [REQ-HAM-PM 2] | The HAM shall support the capability to expose performance information related to the HWA it manages (see NOTE). | +| [REQ-HAM-PM 3] | In response to a query, the HAM shall support the capability to provide the information about active PM jobs which match filtering criteria. | +| NOTE: Performance information can be also related to collected performance information of the LPUs that are operating on the HWA. | | + +**Table 3.1.1-4: Functional requirements for security considerations** + +| | Description | +|-----------------|--------------------------------------------------------------| +| [REQ-HAM-SEC 1] | The HAM shall support being certified by the O-Cloud vendor. | + +**Table 3.1.1-5: Functional requirements for software management** + +| | Description | +|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------| +| [REQ-HAM-SW 1] | The HAM shall support the capability to update and/or upgrade the software for an HWA on the O-Cloud node. See NOTE. | +| NOTE: An example of this may include the programming or re-programming of a downloadable firmware or driver upgrades. Updates/Upgrades can be done locally or remotely. | | + +**Table 3.1.1-6: Functional requirements for HAM registration to IMS exposure of the AAL-C-Mgmt interface** + +| | Description | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------| +| [REQ-HAM-REG 1] | The HAM shall be able to be configured with an IMS service endpoint. | +| [REQ-HAM-REG 2] | The HAM shall be able to be configured with a local HAM service endpoint that the IMS will use to communicate with the HAM. | +| [REQ-HAM-REG 3] | The HAM shall be able to register the HAM service endpoint with the IMS via the AAL-C-Mgmt interface. | + +**Table 3.1.1-7: Functional requirements for HAM related to AAL-Profiles** + +| | Description | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| [REQ-HAM-PROF 1] | The HAM shall provide the ability to retrieve the default values for attributes associated with AAL-Profiles that are supported by the HW Accelerator. See NOTE. | +| [REQ-HAM-PROF 2] | The HAM shall provide the ability to report the default values for attributes associated with AAL-Profiles that are supported by the HW Accelerator. | +| [REQ-HAM-PROF 3] | The HAM shall provide the ability to report the capabilities associated with AAL-Profiles that are supported by the HW Accelerator. | + +NOTE: The mechanisms for the specification and retrieval of the default values for the AAL-Profile are vendor specific behaviour. + +## 3.2 AALI-C App Requirements + +**Table 3.2-1: AALI-C-App Requirements** + +| Requirement Number | Description | Additional Info | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------| +| [REQ-AALI-C-APP-1] | During deployment, the DMS shall provide the AAL Application with a list of LPU identifiers that the DMS has assigned to the AAL Application. | DMS-AAL Interface | +| [REQ-AALI-C-APP-2] | During deployment, the DMS may provide the AAL Application with additional attributes needed by the AAL Implementation for the AAL Implementation to initialize the AAL Implementation for the AAL Application. | DMS-AAL Interface | +| [REQ-AALI-C-APP-3] | During deployment, the AAL Application shall pass the information provided by the DMS that is needed to initialize the AAL Implementation for the AAL Application. | DMS-AAL Interface | +| NOTE: The above AAL requirements (REQ-AALI-C-APP-1 to 3) for DMS to AAL interface are out of scope for the current version of the AAL Common API specification. | | | + +### 3.2.1 AALI-C-APP Transport Abstraction Requirements and Operations + +The transport between an AAL Application and an AAL Implementation can be of different types (e.g., based on shared memory, PCIe interconnect, over Ethernet). AALI-C-App shall support abstraction of these various transport mechanisms between an AAL Application and an AAL Implementation through a set of common transport APIs, constituting a transport abstraction framework. + +**Table 3.2.1-1: AALI-C-App Transport Abstraction Framework Requirements** + +| Requirement Number | Description | Operation | +|-----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------| +| [REQ-AALI-C-APP-TRANSPORT1] | The Transport Abstraction Framework shall provide a method for the AAL Application to request an AAL Implementation to create buffer pool(s) constituting of buffers(s) of one size or more than <i>one size</i> . | createBufferPool (Sec. 5.4.3.1) | +| [REQ-AALI-C-APP-TRANSPORT2] | The Transport Abstraction Framework shall provide a method for the AAL Application to request an AAL Implementation to allocate buffers. | allocBuffer (Sec. 5.4.3.2) | +| [REQ-AALI-APP-TRANSPORT3] | The Transport Abstraction Framework shall support Synchronous (blocking), and Asynchronous (non-blocking) interactions for operations related to sending and receiving buffer(s) by the AAL Application. | sendBuffer (Sec. 5.4.3.5)<br>receiveBuffer (Sec. 5.4.3.6) | +| [REQ-AALI-C-APP-TRANSPORT4] | <p>The Transport Abstraction Framework shall support a method of enabling buffer ownership transfer from the AAL Application to the AAL Implementation.</p> <ul style="list-style-type: none"> <li>When the AAL Application retains ownership of buffer(s), the AAL Implementation shall not free the</li> </ul> | | + +| | | | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------| +| | buffer(s) on completion of an operation until buffer ownership is transferred by the AAL Application. <ul style="list-style-type: none"> <li>If the AAL Application does not retain ownership of the buffer(s), the AAL Implementation shall assume ownership and free the buffer(s) on completion of an operation</li> </ul> | | +| [REQ-AALI-C-APP-TRANSPORT5] | The Transport Abstraction Framework shall support a method for the AAL Application to receive data in the buffer(s) allocated by the AAL Application or the AAL Implementation. | receiveBuffer (Sec. 5.4.3.6) | +| [REQ-AALI-C-APP-TRANSPORT6] | The Transport Abstraction Framework shall support a method for freeing pre-allocated buffer(s). | receiveBuffer (Sec. 5.4.3.6) | +| [REQ-AALI-C-APP-TRANSPORT7] | The Transport Abstraction Framework shall support a method for destroying pre-created buffer pool(s). | freeBuffer (Sec. 5.4.3.7) | +| NOTE: Synchronous (Blocking) API - blocks until the operation is complete and returns the status of the operation execution (success/failure). Asynchronous (Non-Blocking) API - returns immediately before the operation is complete. The AAL Application invoking API calls in this mode can pre-register for a callback. | | | + +## 3.3 AAL Information Model + +### 3.3.1 Overview + +The AALI-C-Mgmt interface is the management interface that is used by the IMS for administrative operations/actions/events. The HAM terminates the AALI-C-Mgmt interface. + +Operations and actions/events via AALI-C-Mgmt are applicable on the following entities: + +- HW Accelerator +- AAL Logical Processing Unit (AAL-LPU) +- AAL Profile + +The AALI-C-App interface is exposed by the AAL Implementation and is used by the AAL Application to discover, configure, and manage the AAL-Profile-Instance(s) and AAL-Profile-Queue(s) in the AAL-LPU assigned to the AAL Application. + +NOTE: An AAL Application may choose to use one or more AAL Profiles as part of its implementation. + +Operations and actions/events via AALI-C-App are applicable on the following entities: + +- AAL Logical Processing Unit (AAL-LPU) +- AAL Profile Instance +- AAL Profile Queue + +![Diagram showing the AAL Information Model architecture. It illustrates the relationship between Logical Managed Resources (AAL-LPU, AA-LPU, AAL-LPU) and Physical Managed Resources (HW Accelerator). AAL Profile Instances (A, B, C, A, E) are shown as components of the AAL-LPU.](99064b33e8d947d1be906d4de4bcf6ce_img.jpg) + +``` + +graph TD + subgraph Logical_Managed_Resource [Logical Managed Resource] + AAL_Profile_Instance_A[AAL Profile Instance A] + AAL_Profile_Instance_B[AAL Profile Instance B] + AAL_Profile_Instance_C[AAL Profile Instance C] + AAL_Profile_Instance_A2[AAL Profile Instance A] + AAL_Profile_Instance_E[AAL Profile Instance E] + AAL_LPU[AAL-LPU] + AA_LPU[AA-LPU] + AAL_LPU2[AAL-LPU] + end + subgraph Physical_Managed_Resource [Physical Managed Resource] + HW_Accelerator[HW Accelerator] + end + AAL_LPU --- HW_Accelerator + AA_LPU --- HW_Accelerator + AAL_LPU2 --- HW_Accelerator + +``` + +Diagram showing the AAL Information Model architecture. It illustrates the relationship between Logical Managed Resources (AAL-LPU, AA-LPU, AAL-LPU) and Physical Managed Resources (HW Accelerator). AAL Profile Instances (A, B, C, A, E) are shown as components of the AAL-LPU. + +**Figure 3.3-1: Physical and Logical resources** + +NOTE: The definition of these entities are defined in GAnP specification [7] section 1.3: The cardinality and relationship between these entities are derived from the GAnP specification [7] section 2.3. The various scenarios supported are also available in the GAnP [7] section 5. + +The Information model defined in [6] will be used to define these managed resources. + +NOTE 1: Usage of 'M', 'O', and 'CM' imply Mandatory, Optional and Conditional Mandatory in the spec + +### 3.3.2 AALI-C-Mgmt Information Model + +#### 3.3.2.1 Imported and associated information entities + +##### 3.3.2.1.1 Imported information entities and local labels + +Information entities imported into the model are used for inheritance purposes. + +**Table 3.3.2.1.1-1 AALI-C-Mgmt Imported Information Entities and Local Labels** + +| Label reference | Local label | +|--------------------------------------------------------------|-------------| +| TS 28.622 [10] Information Object Class, TS 28.620 [11] Top_ | Top_ | + +##### 3.3.2.1.2 Associated information entities and local labels + +Information entities referenced in the model through an association that is not based on inheritance are listed in the associated entities table. + +**Table 3.3.2.1.2-1 AALI-C-Mgmt Associated Information Entities and Local Labels** + +| Label reference | Local label | +|-----------------|-------------| +| | | + +#### 3.3.2.2 Class Diagram + +##### 3.3.2.2.1 Relationships + +``` + +@startuml +skin rose +skinparam ClassStereotypeFontStyle normal +skinparam style strictuml +hide members + +Namespace ORAN.AALI.Mgmt { + +Class "HwAccel (HW Accelerator)" as hwa <<Information Object Class>> { +} + +Class "AalLpu (AAL-LPU)" as lpu <<Information Object Class>> { +} + +Class "AalProfile (AAL Profile)" as profile <<data Type>> { +} + +``` + +``` + +} + +Class "Fault" as fault <<dataType>> { +} + +Class "AalLpuConfiguration" as lpuConfig <<dataType>> { +} + +Class "HW Accelerator Manager" as ham <<Information Object Class>> { +} + +Class "AalProfileTemplate" as aalProfileTemplate <<dataType>> { +} + +hwa "1" *-down- "<U+002B>aalProfileTemplates\n1..*" aalProfileTemplate + +hwa "1" *-down- "<U+002B>aalLpus\n0..*" lpu +hwa "1" -down-> "0..*" fault: faults + +lpu "1" -right-> "0..*" fault: fault +lpu "1..*" -down-> "<U+002B>aalLpuConfig\n1" lpuConfig + +lpu "1" -down-> "<U+002B>supportedAalProfiles\n\t\t\t0..*" profile +} + +@enduml + +``` + +![UML Class Diagram for OCloud.AALI.Mgmt showing relationships between HW Accelerator Manager, AalLpu (AAL-LPU), Fault, AalProfileTemplate, AalProfile (AAL Profile), and AalLpuConfiguration.](841d85cf5bc0c6f05fc5ea8b11311dca_img.jpg) + +``` + +classDiagram + class HWAcceleratorManager["«Information Object Class» HW Accelerator Manager"] + class HwAccel["«Information Object Class» HwAccel (HW Accelerator)"] + class AalLpu["«Information Object Class» AalLpu (AAL-LPU)"] + class Fault["«dataType» Fault"] + class AalProfileTemplate["«dataType» AalProfileTemplate"] + class AalProfile["«dataType» AalProfile (AAL Profile)"] + class AalLpuConfiguration["«dataType» AalLpuConfiguration"] + + HWAcceleratorManager --> AalLpu : +aalLpus 0..* + HwAccel --> AalLpu : 1 + HwAccel --> Fault : 1 faults 0..* + HwAccel --> AalProfileTemplate : 1 +aalProfileTemplates 1..* + AalLpu --> Fault : 1 fault 0..* + AalLpu --> AalProfile : 1 +supportedAalProfiles 0..* + AalLpu --> AalLpuConfiguration : 1 +aalLpuConfig 1 + +``` + +UML Class Diagram for OCloud.AALI.Mgmt showing relationships between HW Accelerator Manager, AalLpu (AAL-LPU), Fault, AalProfileTemplate, AalProfile (AAL Profile), and AalLpuConfiguration. + +Figure 3.3.2.2.1-1: AALI-C-Mgmt Class Relationships + +Editor's Note: Open Action: Requires coordinated adjustment in WG6/WG10 specification. + +Editor's Note: The identification of the HAM and the HAM relationship with the IMS and O-Cloud Infrastructure is FFS. + +##### 3.3.2.2.2 Inheritance + +``` + +@startuml + +skin rose +skinparam ClassStereotypeFontStyle normal + +``` + +``` + +skinparam style strictuml +hide members + +Namespace ORAN.AALI.App { + +Class "AalLpu (AAL-LPU)" as lpu <<Information Object Class>> { +} + +Class "AalProfileInstance (AAL Profile Instance)" as profilei <<Information Object Class>> { +} + +Class "AalProfileQueue (AAL Profile Queue)" as queue <<Information Object Class>> { +} + +lpu "1" *-- "<U+002B>aalProfileInstances\n\t\t\t0..*" profilei +profilei "1" *-down- "<U+002B>aalProfileQueues\n\t\t\t0..*" queue + +} + +@enduml + +``` + +![UML Class Diagram showing AALI-C-Mgmt Class Inheritance. The diagram is titled 'OCloud.AALI.App'. It contains three classes: 'AalLpu (AAL-LPU)', 'AalProfileInstance (AAL Profile Instance)', and 'AalProfileQueue (AAL Profile Queue)'. All three classes are marked as '«Information Object Class»'. 'AalLpu' has an association with 'AalProfileInstance' labeled '+aalProfileInstances' with multiplicity '1' at 'AalLpu' and '0..*' at 'AalProfileInstance'. 'AalProfileInstance' has an association with 'AalProfileQueue' labeled '+aalProfileQueues' with multiplicity '1' at 'AalProfileInstance' and '0..*' at 'AalProfileQueue'.](14878831df8436494a0bcf013fac14cd_img.jpg) + +``` + +classDiagram + class AalLpu["«Information Object Class»\nAalLpu (AAL-LPU)"] + class AalProfileInstance["«Information Object Class»\nAalProfileInstance (AAL Profile Instance)"] + class AalProfileQueue["«Information Object Class»\nAalProfileQueue (AAL Profile Queue)"] + AalLpu "1" -- "0..*" AalProfileInstance : +aalProfileInstances + AalProfileInstance "1" -- "0..*" AalProfileQueue : +aalProfileQueues + +``` + +UML Class Diagram showing AALI-C-Mgmt Class Inheritance. The diagram is titled 'OCloud.AALI.App'. It contains three classes: 'AalLpu (AAL-LPU)', 'AalProfileInstance (AAL Profile Instance)', and 'AalProfileQueue (AAL Profile Queue)'. All three classes are marked as '«Information Object Class»'. 'AalLpu' has an association with 'AalProfileInstance' labeled '+aalProfileInstances' with multiplicity '1' at 'AalLpu' and '0..\*' at 'AalProfileInstance'. 'AalProfileInstance' has an association with 'AalProfileQueue' labeled '+aalProfileQueues' with multiplicity '1' at 'AalProfileInstance' and '0..\*' at 'AalProfileQueue'. + +Figure 3.3.2.2.2-1: AALI-C-Mgmt Class Inheritance + +#### 3.3.2.3 Class Definitions + +##### 3.3.2.3.1 HwAccel <<InformationObjectClass>> + +###### 3.3.2.3.1.1 Definition + +The ORAN.AALI.Mgmt.HwAccel class represents the HW Accelerator. + +###### 3.3.2.3.1.2 Attributes + +Table 3.3.2.3.1.2-1 Attributes Properties for HwAccel + +| Attribute name | Data Type/Description | Properties | +|----------------|--------------------------|------------------------| +| hwAccelId | <b>Data Type:</b> string | x-support-qualifier: M | + +| Attribute name | Data Type/Description | Properties | +|-----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <b>Description:</b> UUID identifier for an instance of the HW Accelerator.<br><br>This identifier is unique within the O-Cloud.<br><br>Data Type pattern and examples are given in [15] | readOnly: False<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>format: uuid | +| operationalState | <b>Data Type:</b> string<br><br><b>Description:</b> Reflects the HW Accelerator's operational state as defined in clause 7.1.1 of ITU X.731. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>nullable: False<br>enum:<br>- DISABLED<br>- ENABLED<br>default: DISABLED | +| operationalConditions | <b>Data Type:</b> array<br><br><b>Description:</b> List of conditions that support the operational state of the entity. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>nullable: False<br>enum:<br>- UNKNOWN<br>- STARTED<br>default: UNKNOWN | +| serialNum | <b>Data Type:</b> string<br><br><b>Description:</b> Serial number of this entity. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False | +| vendorName | <b>Data Type:</b> string<br><br><b>Description:</b> Name of the Vendor/Provider of the entity. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False | +| model | <b>Data Type:</b> string<br><br><b>Description:</b> Information about the model of the entity. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False | +| hwVersion | <b>Data Type:</b> string<br><br><b>Description:</b> Version or generation of the entity. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False<br>example: '1.9.0' | +| maxNumAalLpus | <b>Data Type:</b> integer<br><br><b>Description:</b> This attribute may be included if a HW Accelerator has an upper limit on AAL-LPUs it can support. Actual number of AAL-LPUs available at runtime may be lower based on resource usage, AAL-LPU SW used, and | x-support-qualifier: O<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: True<br>format: integer8<br>minimum: 0 | + +| Attribute name | Data Type/Description | Properties | +|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | AAL-Profile SW and types instantiated on the AAL-LPU(s). | | +| aalProfileTemplates | <b>Data Type:</b> array<br><br><b>Description:</b> The list of AAL-Profile templates supported by the Accelerator. The AAL-Profile templates can be used to configure LPUs within the Accelerator. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>x-isOrdered: False<br>title: AAL-Profile Templates<br>minItems: 1<br>uniqueItems: True<br>items: AalProfileTemplate | +| faults | <b>Data Type:</b> array<br><br><b>Description:</b> The list of current fault conditions. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>nullable: False<br>x-isOrdered: False<br>title: faults<br>maxItems: *<br>minItems: 0<br>uniqueItems: True<br>items: Fault | +| lpuType | <b>Data Type:</b> string<br><br><b>Description:</b> The method to apply the configuration settings for the aalLpus associated with a HW Accelerator. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>enum:<br>- Single<br>- Mixed<br>default: Mixed | +| numAalLpusConfigured | <b>Data Type:</b> integer8<br><br><b>Description:</b> The number of aalLpus currently configured. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>format: integer8<br>minimum: 0 | +| aalLpus | <b>Data Type:</b> array<br><br><b>Description:</b> The list of AAL-LPUs configured for this HW Accelerator.<br><br>The number of aalLpu instances is determined by the value of the numAalLpusConfigured attribute. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>x-isOrdered: False<br>title: AAL LPUs<br>minItems: 0<br>uniqueItems: True<br>items: AalLpu | +| imageVersion | <b>Data Type:</b> string<br><br><b>Description:</b> The version for the image applied to the HW Accelerator. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>example: '1.9.0' | +| imageLocation | <b>Data Type:</b> string<br><br><b>Description:</b> URI[16] Path to the software/firmware image. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>format: uri | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> The list of | x-support-qualifier: M<br>x-isInvariant: False | + +| | | | +|--|--------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | unspecified (not standardized) properties for the entity which are tailored by the vendor. | x-inventoryNotification True<br>nullable: False<br>x-isOrdered: False<br>title: extensions<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair | +|--|--------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------| + +###### 3.3.2.3.1.3 Attribute constraints + +None + +###### 3.3.2.3.1.4 State diagram + +###### 3.3.2.3.1.4.1 Introduction + +The HWAccel maintains an operational state of the entity as defined in clause 7.1.1 of ITU X.731 [14]. How the HW Accel determines its operational state is implementation specific. + +##### 3.3.2.3.2 AalLpu <<InformationObjectClass>> + +###### 3.3.2.3.2.1 Definition + +The ORAN.AALI.Mgmt.AalLpu class represents the AAL-LPU. + +###### 3.3.2.3.2.2 Attributes + +**Table 3.3.2.3.2.2-1 Attributes Properties for AalLpu** + +| Attribute name | Data Type/Description | Properties | +|-----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| aalLpuId | <b>Data Type:</b> string<br><br><b>Description:</b> UUID identifier for an instance of the AAL-LPU.<br><br>This identifier is unique within the O-Cloud.<br><br>Data Type pattern and examples are given in [15] | x-support-qualifier: M<br>readOnly: False<br>x-isInvariant: False<br>x-inventoryNotification True<br>nullable: False<br>format: uuid | +| operationalState | <b>Data Type:</b> string<br><br><b>Description:</b> Reflects the AAL-LPU's operational state as defined in clause 7.1.1 of ITU X.731. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification False<br>nullable: False<br>enum:<br>- DISABLED<br>- ENABLED<br>default: DISABLED | +| operationalConditions | <b>Data Type:</b> array<br><br><b>Description:</b> List of conditions that support the operational state of the entity. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification False<br>nullable: False<br>enum:<br>- UNKNOWN<br>- STARTED<br>- STARTINGUP<br>- SHUTTINGDOWN | + +| Attribute name | Data Type/Description | Properties | +|----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | - STOPPED<br>default: UNKNOWN | +| faults | <b>Data Type:</b> array<br><br><b>Description:</b> The list of current fault conditions. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br><br>x-inventoryNotification: False<br>nullable: False<br>x-isOrdered: False<br>title: faults<br>maxItems: *<br>minItems: 0<br>uniqueItems: True<br>items: Fault | +| supportedAalProfiles | <b>Data Type:</b> array<br><br><b>Description:</b> The list of supported AAL Profiles. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>x-isOrdered: False<br>title: AAL Profiles<br><br>minItems: 0<br>uniqueItems: True<br>items: AalProfile | +| imageVersion | <b>Data Type:</b> string<br><br><b>Description:</b> The version or generation for the image applied to the entity.<br><br>If an AAL-LPU image is the same as the Accelerator HW's image, then the HW Accelerator's imageVersion attribute and this attribute would contain the same value. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>example: '1.9.0' | +| imageLocation | <b>Data Type:</b> string<br><br><b>Description:</b> URI [16] Path to the software/firmware image.<br><br>If an AAL-LPU image is the same as the Accelerator HW's image, then the HW Accelerator's imageLocation attribute and this attribute would contain the same value. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>format: uri | +| aalLpuConfig | <b>Data Type:</b> AalLpuConfig<br><br><b>Description:</b> The common configuration attributes that are common to one or more AAL-LPUs including this AAL-LPU. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False | + +###### 3.3.2.3.2.3 Attribute constraints + +None + +###### 3.3.2.3.2.4 State diagram + +###### 3.3.2.3.2.4.1 Introduction + +The AAL-LPU maintains an operational state of the entity as defined in clause 7.1.1 of ITU X.731 [14]. How the AAL-LPU determines its operational state is implementation specific. + +##### 3.3.2.3.3 AalProfile <<dataType>> + +###### 3.3.2.3.3.1 Definition + +The ORAN.AALI.Mgmt.AalProfile class represents the AAL-Profile. + +###### 3.3.2.3.3.2 Attributes + +**Table 3.3.2.3.3.2-1 Attributes Properties for AalProfile** + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Name identifier of the AAL Profile. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False<br>format: string | +| version | <b>Data Type:</b> string<br><br><b>Description:</b> The version of AAL Profile. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>example: '1.9.0' | +| imageVersion | <b>Data Type:</b> string<br><br><b>Description:</b> The version or generation for the image of the entity.<br><br>If an AAL-Profile image is the same as the AAL-LPU's image then the AAL-LPU's imageVersion attribute and this attribute would contain the same value. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>example: '1.9.0' | +| imageLocation | <b>Data Type:</b> string<br><br><b>Description:</b> Path to the software/firmware image.<br><br>If an AAL-Profile image is the same as the AAL-LPU's image then the AAL-LPU's imageLocation attribute and this attribute would contain the same value. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>format: uri | +| attributes | <b>Data Type:</b> array<br><br><b>Description:</b> The list of AAL-Profile attributes represented as key/value pairs.<br><br>The values for entries in this list that are duplicates of entries in the AALProfileTemplate's attributes | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False<br>x-isOrdered: False<br>title: Attributes<br>minItems: 0<br>uniqueItems: True<br>items: AttributeVa | + +| Attribute name | Data Type/Description | Properties | +|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | attribute override the value provided by the AALProfileTemplate attributes attribute's entry. | AttributeVa<br>luePair | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> The list of AAL-Profile unspecified (not standardized) attributes represented as key/value pairs. The structure and format of the value attribute is specified as part of the definition of the key.<br><br>The values for entries in this list that are duplicates of entries in the AALProfileTemplate's extensions attribute override the value provided by the AALProfileTemplate extensions attribute's entry. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification True<br>nullable: False<br>x-isOrdered: False<br>title: Extension<br>Attributes<br>minItems: 0<br>uniqueItems: True<br>items: AttributeVa<br>luePair | + +###### 3.3.2.3.3.3 Attribute constraints + +None + +###### 3.3.2.3.3.4 State diagram + +None + +##### 3.3.2.3.4 Fault <<dataType>> + +###### 3.3.2.3.4.1 Definition + +The ORAN.AALI.Mgmt.Fault class represents a current Fault condition associated with an entity. + +###### 3.3.2.3.4.2 Attributes + +**Table 3.3.2.3.4.2-1 Attributes Properties for Fault** + +| Attribute name | Data Type/Description | Properties | +|----------------|--------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------| +| faultId | <b>Data Type:</b> string<br><br><b>Description:</b> The identifier for the fault condition. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification False<br>nullable: False | +| detectedTime | <b>Data Type:</b> string<br><br><b>Description:</b> The date and time the fault condition was last detected. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification False<br>nullable: False<br>format: date-time | + +###### 3.3.2.3.4.3 Attribute constraints + +None + +###### 3.3.2.3.4.4 State diagram + +None + +##### 3.3.2.3.5 AalLpuConfig <<dataType>> + +###### 3.3.2.3.3.1 Definition + +The ORAN.AALI.Mgmt.AalLpuConfig class represents the AAL-LPU configuration settings to be applied to an instance of an AAL-LPU. + +The AAL-LPU's HW Accelerator determines how the AAL-LPU configuration settings are applied using the HW Accelerators lpuType and numAalLpusConfigured attributes. If the lpuType attribute's value is "mixed", then each AAL-LPU for the HW Accelerator has a different instance of the AalLpuConfig entity. If the lpuType attribute's value is "single" then all AAL-LPUs for the HW Accelerator share the same instance of the AalLpuConfig entity. + +###### 3.3.2.3.5.2 Attributes + +**Table 3.3.2.3.5.2-1 Attributes Properties for AalLpuConfig** + +| Attribute name | Data Type/Description | Properties | +|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| memory | <b>Data Type:</b> integer<br><br><b>Description:</b> Memory allocated to this entity. | x-support-qualifier: 0<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: True<br>format: integer64<br>x-units: bytes | +| multiprocessorNum | <b>Data Type:</b> integer<br><br><b>Description:</b> Number of multiprocessors allocated to this entity. | x-support-qualifier: 0<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: True<br>format: integer8<br>minimum: 1 | +| computeSlicesNum | <b>Data Type:</b> integer<br><br><b>Description:</b> Number of compute-slices allocated to this entity. | x-support-qualifier: 0<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: True<br>format: integer8<br>minimum: 1 | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> The list of unspecified (not standardized) properties defined by vendors that used for the configuration of the AAL-LPU.of the AAL-LPU. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>nullable: False<br>x-isOrdered: False<br>title: Extensions<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair | + +###### 3.3.2.3.5.3 Attribute constraints + +None + +###### 3.3.2.3.5.4 State diagram + +None + +##### 3.3.2.3.6 AalProfileTemplate <<data Type>> + +###### 3.3.2.3.6.1 Definition + +The ORAN.AALI.Mgmt.AalProfileTemplate class represents the version of the AAL-Profile template for capabilities and default configurations reported by the HW Accelerator. + +###### 3.3.2.3.6.2 Attributes + +**Table 3.3.2.3.6.2-1 Attributes Properties for AalProfileTemplate** + +| Attribute name | Data Type/Description | Properties | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Name identifier of the AAL Profile template. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False<br>format: string | +| version | <b>Data Type:</b> string<br><br><b>Description:</b> The version or AAL Profile Template | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False<br>example: '1.9.0' | +| imageVersion | <b>Data Type:</b> string<br><br><b>Description:</b> The version or generation for the image of the entity.<br><br>If an AAL-Profile image is the same as the AAL-LPU's image then the AAL-LPU's imageVersion attribute and this attribute would contain the same value. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False<br><br>example: '1.9.0' | +| attributes | <b>Data Type:</b> array<br><br><b>Description:</b> The list of AAL-Profile attributes represented as key/value pairs.<br><br>Values for entries in this attribute would be considered the initial or default configuration setting for entries with the associated key. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False<br>x-isOrdered: False<br>title: Attributes<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> The list of AAL-Profile unspecified (not standardized) capabilities and attributes represented as key/value pairs. The structure and format of the value attribute is specified as part of the definition of the key.<br><br>Values for attribute entries in this attribute would be considered the initial or default | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False<br>x-isOrdered: False<br>title: Extension Capabilities and Attributes<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair | + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | configuration setting for entries with the associated key. | | +| capabilities | <b>Data Type:</b> array<br><br><b>Description:</b> The list of AAL-Profile specified capabilities represented as key/value pairs. The structure and format of the value attribute is specified as part of the definition of the key in the corresponding AAL Profile specification. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>nullable: False<br>x-isOrdered: False<br>title: Capabilities<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair | + +###### 3.3.2.3.6.3 Attribute constraints + +None + +###### 3.3.2.3.6.4 State diagram + +None + +##### 3.3.2.3.7 AalHam <<InformationObjectClass>> + +###### 3.3.2.3.7.1 Definition + +The ORAN.AALI.Mgmt.AalHam class represents the HAM acceleration management function. + +###### 3.3.2.3.7.2 Attributes + +**Table 3.3.2.3.7.2-1 Attributes Properties for AalHam** + +| Attribute name | Data Type/Description | Properties | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | +| operationalState | <b>Data Type:</b> string<br><br><b>Description:</b> Reflects the HAM's operational state as defined in clause 7.1.1 of ITU X.731. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False<br>enum:<br>- DISABLED<br>- ENABLED<br>default: DISABLED | +| imsRegistrationState | <b>Data Type:</b> string<br><br><b>Description:</b> Reflects the registration state of HAM toward the IMS. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False<br>enum:<br>- NOTREGISTERED<br>- REGISTERED<br>default: | + +| Attribute name | Data Type/Description | Properties | +|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------| +| | | NOTREGISTERED | +| localServiceEndpoint | <b>Data Type:</b> string<br><b>Description:</b> The service endpoint that the HAM exposes to the IMS that permits the IMS to send requests to the HAM and receive notifications from the HAM. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification True<br>nullable: False<br>format: uri | +| registrationServiceEndpoint | <b>Data Type:</b> string<br><b>Description:</b> The service endpoint that the HAM uses register with the IMS in order for the IMS to connect to and manage the HAM. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification True<br>nullable: False<br>format: uri | + +3.3.2.3.7.3 + +###### Attributes Constraints + +**Table 3.3.2.3.7.3 -1 Attributes Constraints for AalHam** + +| Name | Definition | +|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------| +| imsRegistrationState | Condition:<br>Modification of the localServiceEndpoint or registrationServiceEndpoint will cause the HAM to invoke the de-registration transition. | + +###### 3.3.2.3.7.4 State diagram + +###### 3.3.2.3.7.4.1 Introduction + +The HAM maintains an operational state of the HAM as defined in clause 7.1.1 of ITU X.731 [14]. How the HAM determines its operational state is implementation specific. + +The HAM maintains an IMS Registration state that reflects the HAMs current registration with an IMS. + +###### 3.3.2.3.7.4.2 imsRegistrationState diagram + +``` + +@startuml +skin rose +skinparam ClassStereotypeFontStyle normal +skinparam style strictuml +hide members + + NotRegistered: imsRegistrationState = NOTREGISTERED + NotRegistered--> NotRegistered: Registration failure + NotRegistered--> Registered: Registration successful + Registered : imsRegistrationState = REGISTERED + Registered --> NotRegistered: De-Registration successful +enduml + +``` + +![State Diagram for AalHam Registration with IMS. The diagram shows two states: 'NotRegistered' and 'Registered'. 'NotRegistered' has a self-loop labeled 'Registration failure'. Transitions between the states are labeled 'Registration successful' and 'De-Registration successful'.](543a4f9019f760c34a5c5e5ca701ebb7_img.jpg) + +``` + +stateDiagram-v2 + state NotRegistered { + imsRegistrationState = NOTREGISTERED + } + state Registered { + imsRegistrationState = REGISTERED + } + NotRegistered --> NotRegistered : Registration failure + NotRegistered --> Registered : Registration successful + Registered --> NotRegistered : De-Registration successful + +``` + +State Diagram for AalHam Registration with IMS. The diagram shows two states: 'NotRegistered' and 'Registered'. 'NotRegistered' has a self-loop labeled 'Registration failure'. Transitions between the states are labeled 'Registration successful' and 'De-Registration successful'. + +**Figure 3.3.3.2.1-1:State Diagram for AalHam Registration with IMS** + +### 3.3.3 AALI-C-App Information Model + +#### 3.3.3.1 Imported and associated information entities + +##### 3.3.3.1.1 Imported information entities and local labels + +Information entities imported into the model are used for inheritance purposes. + +**Table 3.3.3.1.1-1 AALI-C-App Imported Information Entities and Local Labels** + +| Label reference | Local label | +|--------------------------------------------------------------|-------------| +| TS 28.622 [10] Information Object Class, TS 28.620 [11] Top_ | Top_ | + +##### 3.3.3.1.2 Associated information entities and local labels + +None + +#### 3.3.3.2 Class Diagram + +##### 3.3.3.2.1 Relationships + +``` + +@startuml +skin rose +skinparam ClassStereotypeFontStyle normal +skinparam style strictuml +hide members + +Namespace ORAN.AALI.App { +Class "AalLpu (AAL-LPU)" as lpu <<Information Object Class>> { +} + +Class "AalProfileInstance (AAL Profile Instance)" as profilei <<Information Object Class>> { +} + +Class "AalProfileQueue (AAL Profile Queue)" as queue <<Information Object Class>> { +} +} + +``` + +``` + +lpu "1" *-- "0..n" profilei: aalProfileInstances +profilei "1" *-down- "0..n" queue: aalProfileQueues +} + +@enduml + +``` + +![UML Class Diagram showing AAL-C-App Class Relationships. The diagram is titled 'OCloud.AALI.App'. It contains three classes: 'AalLpu (AAL-LPU)', 'AalProfileInstance (AAL Profile Instance)', and 'AalProfileQueue (AAL Profile Queue)'. All three classes are marked as '«Information Object Class»'. 'AalLpu' has a directed association to 'AalProfileInstance' with the role 'aalProfileInstances', multiplicity '1' at 'AalLpu' and '0..n' at 'AalProfileInstance'. 'AalProfileInstance' has a directed association to 'AalProfileQueue' with the role 'aalProfileQueues', multiplicity '1' at 'AalProfileInstance' and '0..n' at 'AalProfileQueue'.](09972ba5e7e651a90b65097e7b0655d7_img.jpg) + +``` + +classDiagram + class AalLpu["«Information Object Class»\nAalLpu (AAL-LPU)"] + class AalProfileInstance["«Information Object Class»\nAalProfileInstance (AAL Profile Instance)"] + class AalProfileQueue["«Information Object Class»\nAalProfileQueue (AAL Profile Queue)"] + AalLpu "1" --> "0..n" AalProfileInstance : aalProfileInstances + AalProfileInstance "1" --> "0..n" AalProfileQueue : aalProfileQueues + +``` + +UML Class Diagram showing AAL-C-App Class Relationships. The diagram is titled 'OCloud.AALI.App'. It contains three classes: 'AalLpu (AAL-LPU)', 'AalProfileInstance (AAL Profile Instance)', and 'AalProfileQueue (AAL Profile Queue)'. All three classes are marked as '«Information Object Class»'. 'AalLpu' has a directed association to 'AalProfileInstance' with the role 'aalProfileInstances', multiplicity '1' at 'AalLpu' and '0..n' at 'AalProfileInstance'. 'AalProfileInstance' has a directed association to 'AalProfileQueue' with the role 'aalProfileQueues', multiplicity '1' at 'AalProfileInstance' and '0..n' at 'AalProfileQueue'. + +Figure 3.3.3.2.1-1: AALI-C-App Class Relationships + +##### 3.3.3.2.2 Inheritance + +``` + +@startuml +skin rose +skinparam ClassStereotypeFontStyle normal +skinparam style strictuml +hide members + +abstract class "Top_" as top <<Information Object Class>> +class "AalLpu (AAL-LPU)" as lpu <<Information Object Class>> +class "AalProfileInstance (AAL Profile Instance)" as profilei <<Information Object Class>> +class "AalProfileQueue (AAL Profile Queue)" as queue <<Information Object Class>> + +note right of top + defined in + 3GPP TS 28.620 + clause 4.3.8 +end note + +top <|-- lpu +top <|-- profilei +top <|-- queue + +@enduml + +``` + +![UML Class Inheritance Diagram for AALI-C-App. The diagram shows three subclasses at the bottom: '«Information Object Class» AalLpu (AAL-LPU)', '«Information Object Class» AalProfileInstance (AAL Profile Instance)', and '«Information Object Class» AalProfileQueue (AAL Profile Queue)'. All three have solid arrows pointing to a superclass at the top: '«Information Object Class» Top_'. A dashed line connects 'Top_' to a yellow note box on the right that says 'defined in 3GPP TS 28.620 clause 4.3.8'.](87d40fffb030b8d98b03ac2f64781a1d_img.jpg) + +``` + +classDiagram + class Top_["«Information Object Class» Top_"] + class AalLpu["«Information Object Class» AalLpu (AAL-LPU)"] + class AalProfileInstance["«Information Object Class» AalProfileInstance (AAL Profile Instance)"] + class AalProfileQueue["«Information Object Class» AalProfileQueue (AAL Profile Queue)"] + Top_ <|-- AalLpu + Top_ <|-- AalProfileInstance + Top_ <|-- AalProfileQueue + Top_ -.- Note["defined in 3GPP TS 28.620 clause 4.3.8"] + +``` + +UML Class Inheritance Diagram for AALI-C-App. The diagram shows three subclasses at the bottom: '«Information Object Class» AalLpu (AAL-LPU)', '«Information Object Class» AalProfileInstance (AAL Profile Instance)', and '«Information Object Class» AalProfileQueue (AAL Profile Queue)'. All three have solid arrows pointing to a superclass at the top: '«Information Object Class» Top\_'. A dashed line connects 'Top\_' to a yellow note box on the right that says 'defined in 3GPP TS 28.620 clause 4.3.8'. + +**Figure 3.3.3.2.2-1: AALI-C-App Class Inheritance** + +#### 3.3.3.3 Class Definitions + +##### 3.3.3.3.1 AalLpu <<InformationObjectClass>> + +###### 3.3.3.3.1.1 Definition + +The ORAN.AALI.App.AalLpu class represents the runtime instance of an AAL-LPU entity. + +###### 3.3.3.3.1.2 Attributes + +**Table 3.3.3.3.1.2-1 Attributes Properties for AalLpu** + +| Attribute name | Data Type/Description | Properties | +|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| aalLpuHandle | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier that represents the handle (e.g., pointer) that the AAL Application uses to access the AAL-LPU exposed by the AAL Implementation<br><br>This identifier is unique between the AAL Implementation and the AAL Application.<br><br>The identifier is assigned by the AAL Implementation. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>nullable: False<br>format: binary | +| aalProfileInstances | <b>Data Type:</b> array<br><br><b>Description:</b> The list of AAL-Profile instances created by the AAL Application for this AAL-LPU. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: AalProfileI<br>nstance | + +###### 3.3.3.3.2.3 Attribute constraints + +None + +###### 3.3.3.3.1.4 State diagram + +Section 5.3.1 of this present document describes the state diagram for this entity. + +##### 3.3.3.3.2 AalProfileInstance <<InformationObjectClass>> + +###### 3.3.3.3.2.1 Definition + +The ORAN.AALI.App. AalProfileInstance class represents the runtime instance of an AAL-Profile entity. + +###### 3.3.3.3.2.2 Attributes + +**Table 3.3.3.3.2-1 Attributes Properties for AalProfileInstance** + +| Attribute name | Data Type/Description | Properties | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| aalProfileInstanceHandle | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier that represents the handle (e.g., pointer) that the AAL Application uses to access the AAL-Profile instance exposed by the AAL Implementation<br><br>This identifier is unique between the AAL Implementation and the AAL Application.<br><br>The identifier is assigned by the AAL Implementation. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>nullable: False<br>format: binary | +| aalProfileName | <b>Data Type:</b> string<br><br><b>Description:</b> Name identifier of the AAL Profile. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>nullable: False<br>format: string | +| aalProfileVersion | <b>Data Type:</b> string<br><br><b>Description:</b> The version of the AAL Profile. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>nullable: False<br>example: '1.9.0' | +| aalProfileQueues | <b>Data Type:</b> array<br><br><b>Description:</b> The list of AAL-Profile Queues created by the AAL Application for this AAL-Profile instance. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AalProfileQueue | + +###### 3.3.3.3.2.3 Attribute constraints + +None + +###### 3.3.3.3.2.4 State diagram + +Section 5.3.1 of this present document describes the state diagram for this entity. + +##### 3.3.3.3.3 AalProfileQueue <<InformationObjectClass>> + +###### 3.3.3.3.3.1 Definition + +The ORAN.AALI.App.AalProfileQueue class represents the runtime instance of an AAL-Profile-Queue entity. + +###### 3.3.3.3.3.2 Attributes + +**Table 3.3.3.3.2-1 Attributes Properties for AalProfileQueue** + +| Attribute name | Data Type/Description | Properties | +|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| aalProfileQueueHandle | <p><b>Data Type:</b> string</p> <p><b>Description:</b> Identifier that represents the handle (e.g., pointer) that the AAL Application uses to access the AAL-Profile-Queue instance exposed by the AAL Implementation</p> <p>This identifier is unique between the AAL Implementation and the AAL Application.</p> <p>The identifier is assigned by the AAL Implementation.</p> | <p>x-support-qualifier: M</p> <p>readOnly: True</p> <p>x-isInvariant: True</p> <p>x-inventoryNotification: False</p> <p>nullable: False</p> <p>format: binary</p> | + +###### 3.3.3.3.3.3 Attribute constraints + +None + +###### 3.3.3.3.3.4 State diagram + +Section 5.3.1 of this present document describes the state diagram for this entity. + +### 3.3.4 Naming convention and managed resource tags + +#### 3.3.4.1 API managed resources tags + +For the following managed resources, the associated API managed resource tags will be used: + +**For the managed resources:** + +- HW Accelerator - **HW-Accel** +- AAL LPU - **AAL-LPU** +- AAL Profile Instance - **AAL-Profile-Instance** +- AAL Profile Queue - **AAL-Profile-Queue** + +**Profile Naming convention:** + +- FEC Profile – **AAL-FEC** +- L1 DL High Phy Profile – **AAL-DOWNLINK-High-PHY** +- L1 UL High Phy Profile – **AAL-UPLINK-High-PHY** + +#### 3.3.4.2 API Naming Conventions + +##### Operations and parameters naming convention: + +- lowerCamelCase for operation names +- lower\_snake\_case for parameters + +##### Group of attributes are notified with a > sign. + +Example: + +A grouped list of variables a, b and c under one parameter i.e. parameter\_name is shown as follows: + +| parameter_name | struct | +|----------------|--------| +| >a | | +| >b | | +| >c | | + +#### 3.3.4.3 Model Conventions + +The conventions for the development of the Information Model are derived from the following sources: + +3GPP TS 32.156 [1] provides the basis of the Class definitions for modelling elements that also includes the Stereotypes to be used when defining Classes. 3GPP TS 32.156 also includes the descriptions in clause 5.2.1.1 of the 3GPP standard Class attribute properties. + +OAS 3.0 Specification [13] provides the basis for the Information Model data types. The Swagger documentation provides additional descriptions for the Class Attribute properties. + +# Chapter 4 AALI-C-Mgmt + +## 4.1 AALI-C-Mgmt operations and events + +The below table lists the operations and events as part of the AALI-C-Mgmt interface. + +Note: The present document version does not contain details of all the operations listed in the table below. The operations marked TBD need further evaluation. + +**Table 4.1-1: AALI-C-Mgmt operations and events** + +| Category | Operations/Events | Objects | +|----------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| <b>Capabilities discovery and Configuration Services</b> | | | +| <b>Get Configuration Services</b> | Get configuration <ul style="list-style-type: none"> <li>• getAalHwAccelStatus</li> <li>• getAalLpuStatus</li> <li>• getAalAccelInfo (inventory and capabilities)</li> <li>• getPmCounters</li> </ul> | HW-Accel<br><br>AAL-LPU | +| <b>Set Configuration Services</b> | Set configuration (add/modify/delete) configuration (initial and inline updates): | HW-Accel<br><br>AAL-LPU | + +| | | | +|-------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------|---------------------| +| | <ul style="list-style-type: none"> <li>setAalAccelConfig</li> <li>setPmCollectionInterval (granularity/reporting etc.) (TBD)</li> </ul> | | +| | Set identification of the managed resource. <ul style="list-style-type: none"> <li>setAalAccelIdentifier</li> </ul> | HW-Accel | +| <b>Inventory Notification</b> | Inventory notification event <ul style="list-style-type: none"> <li>aalInventoryNotification</li> </ul> | HW-Accel<br>AAL-LPU | +| <b>Infrastructure Monitoring Services</b> | | | +| <b>Fault Service Operations</b> | <ul style="list-style-type: none"> <li>getAalHwAccelFaults</li> <li>getAalLpuFaults</li> </ul> | HW-Accel<br>AAL-LPU | +| | <ul style="list-style-type: none"> <li>manageLogs (Start/Stop/Get logs (Fault, debug))</li> </ul> | HW-Accel<br>AAL-LPU | +| <b>Fault Subscription</b> | <ul style="list-style-type: none"> <li>createAalFaultSubscription</li> <li>deleteAalFaultSubscription</li> <li>getAalFaultSubscription</li> </ul> | HW-Accel<br>AAL-LPU | +| <b>Fault Notification</b> | <ul style="list-style-type: none"> <li>aalFaultNotification</li> </ul> | HW-Accel<br>AAL-LPU | +| <b>State Change Notification</b> | <ul style="list-style-type: none"> <li>State Change notification (Autonomous)</li> </ul> | HW-Accel<br>AAL-LPU | +| <b>PM Service Operations</b> | <ul style="list-style-type: none"> <li>PM Subscription</li> </ul> | HW-Accel<br>AAL-LPU | +| | <ul style="list-style-type: none"> <li>Reporting of PM (file, streaming etc)</li> </ul> | HW-Accel<br>AAL-LPU | +| <b>Operational Commands</b> | | | +| <b>Operational commands</b> | <ul style="list-style-type: none"> <li>restartHwAccel (TBD)</li> <li>resetHwAccel (TBD)</li> </ul> | HW-Accel | +| | <ul style="list-style-type: none"> <li>powerCycleHwAccel (TBD)</li> </ul> | HW-Accel | +| | <ul style="list-style-type: none"> <li>startAalLpu</li> </ul> | AAL-LPU | +| | <ul style="list-style-type: none"> <li>stopAalLpu</li> </ul> | AAL-LPU | +| | <ul style="list-style-type: none"> <li>initiateTest (TBD)</li> </ul> | HW-Accel<br>AAL-LPU | +| <b>HAM Operations</b> | | | +| <b>IMS Registration</b> | <ul style="list-style-type: none"> <li>aalHamRegistrationNotification</li> </ul> | HAM | + +## 4.2 AALI-C-Mgmt use case workflows + +### 4.2.1 HW Accelerator installation/bootstrap use case workflow + +This use case describes the procedure with a focus on the interaction of IMS with the HAM when installing and optionally configuring the HW Accelerator resource and configuring the AAL-LPUs resources. This procedure would be applicable during the initial deployment of an O-Cloud and afterward to reconfigure or add new resources. + +This AAL UC flow can be executed during the O-Cloud Registration and Initialization Use Case, O-Cloud Inventory Update Use Case and the Hardware Infrastructure Scaling of O-Cloud Post Deployment Use Case [ Ref[5]: 3.1.3 “O-Cloud Registration and Initialization Use Case”, Configure AAL-LPU “3.1.4 : O-Cloud Inventory Update Use Case (DMS Example)” and “3.1.5: Hardware Infrastructure Scaling of O-Cloud Post Deployment”]. + +**Table 4.2.1-1: HW Accelerator installation/bootstrap workflow steps** + +| | <b>Evolution / Specification</b> | <b><<Uses>><br/>Related use</b> | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------| +| Goal | Install the HW Accelerator and update the IMS that the HW Accelerator is available. | | +| Actors and Roles | Cloud Installer, SMO, FOCOM, IMS, HAM<br><br>SW Repo: Software repository | | +| Assumptions | This UC can be applicable during the O-Cloud Registration and Initialization or during Hardware Infrastructure Scaling of O-Cloud Post Deployment. | | +| Pre-conditions | SMO/FOCOM is active and running normally<br><br>O-Cloud is available<br><br>IMS is operational<br><br>HAM is operational and registered with the IMS<br><br>SMO and IMS connectivity is established<br><br>Accelerator SW Repository is accessible to HAM and populated with needed files. | | +| Begins when | SMO sends request to install the HW Accelerator | | +| Step 1 (M) | The IMS updates its inventory with the O-Cloud Resource information for the HW Accelerator discovered by the HAM.<br><br>The IMS obtains, via the AALI-C-Mgmt interface, the managed resource information for the HW Accelerator through reception of an inventory notification event for additions of HW Accelerator(s). | | +| Step 2-3 (O) | If the IMS needs to assign the identifier of the HW Accelerator, the IMS sets the HW Accelerator’s identifier by sending the setAalAccelIdentifier request to the HAM. | | +| Steps 4-7(O) | If the HW Accelerator status information is exchanged, additionally optionally the IMS can get the AAL-LPU status(es). | | + +| | | | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| Steps 8-9 (O) | Optionally the IMS can get the HW Accelerator configuration | | +| Step 10-11 (O) | Optionally the IMS can configure the HW Accelerator (via the HAM): If the IMS (or SMO) determines that different image(s) should be used it may send a setAalAccelConfig request to the HAM, if the HAM determines new binaries, SW or configuration artifacts are needed from a SW repo, they are fetched, verified, and installed.<br><br>SMO is informed about the status if the operation | | +| Ends when | HW Accelerator inventory has been received by the IMS and IMS has optionally configured the HW Accelerator. | | +| Exceptions | None identified | | +| Post Conditions | The HW Accelerator has been deployed on the O-Cloud. | | +| Traceability | To be added later | | + +#### 4.2.1.1 Sequence Diagram + +``` + +@startuml +skinparam sequenceArrowThickness 1 +skinparam ParticipantPadding 2 +skinparam BoxPadding 5 +Autonumber + +Box "Personnel" #lightblue + Actor Installer as "Cloud Installer" +End box + +Box "Service Management & Orchestration Framework" #gold + Participant "FOCOM" as FCC +End box + +Box "O-Cloud" "#lightseagreen" + Participant "IMS" as IMS + Participant AccelMgr as "HAM" +End box + +Box "SW Repo" #grey + Participant "SW Repo" as Repo +End Box + +Note over Installer, IMS + PRECONDITIONS: + SMO/FOCOM is active and running normally + O-Cloud is available + IMS is operational + HAM is operational and registered with the IMS + SMO and IMS connectivity is established + IMS and HAM connectivity is established + HW Accel(s) installed + HAM connection to HW Accel(s) is established +End Note + +AccelMgr --> IMS : <<AALI-C-Mgmt>> aalInventoryNotification (inc SW/FW/Config - same params as getAalAccelInfo) + +Note over FCC, IMS + IMS informs SMO of the HW Accelerator Inventory + SMO Updates inventory with the HW Accelerator inventory information + +``` + +``` + +End Note + +Opt + Note over IMS, AccelMgr + If IMS needs to set the identifier of the HW Accel using the HW Accelerator + vendor_name, model and serial_number input parameters. + End Note + + IMS -> AccelMgr : <<AALI-C-Mgmt>> setAalAccelIdentifier request + AccelMgr -> IMS : <<AALI-C-Mgmt>> setAalAccelIdentifier response (success) +End Opt + +Opt + IMS -> AccelMgr : <<AALI-C-Mgmt>> getAalHwAccelStatus request + AccelMgr -> IMS : <<AALI-C-Mgmt>> getAalHwAccelStatus response (success) + opt + IMS -> AccelMgr : <<AALI-C-Mgmt>> getAalLpuStatus request + AccelMgr -> IMS : <<AALI-C-Mgmt>> getAalLpuStatus response (success) + End opt +End opt + +Opt + IMS -> AccelMgr : <<AALI-C-Mgmt>> getAalAccelInfo request + AccelMgr -> IMS : <<AALI-C-Mgmt>> getAalAccelInfo response (success) +End opt + +Note over FCC, IMS + SMO optionally instructs IMS to configure HW Accelerator + boot image or other config/SW/config artifact +End Note + +Opt + Note over IMS, AccelMgr + If boot image or other config/SW/config artifact is needed or new driver is needed + (in order to match an intended configuration) then it is set using setAalAccelConfig +API + End Note + + IMS -> AccelMgr : <<AALI-C-Mgmt>> setAalAccelConfig request + Note over AccelMgr, Repo + Download & apply needed + binaries, images, FW, etc. + End note + AccelMgr -> IMS : <<AALI-C-Mgmt>> setAalAccelConfig response (success) +End Opt + +Note over FCC, IMS + HW Accelerator is installed and SMO has the inventory + information about the HW Accelerator. + SMO inventory is updated + resouce information +End Note +@enduml + +``` + +![Sequence diagram for end-2-end Life Cycle Management use case workflow. The diagram shows interactions between Personnel (Cloud Installer), Service Management & Orchestration Framework (FOCOM, IMS), O-Cloud (HAM), and SW Repo. The flow starts with preconditions, followed by a notification from IMS to FOCOM. Then, FOCOM sends a request to IMS to set the HW Accelerator identifier. This is followed by optional steps for getting status and configuration information. Finally, FOCOM sends a request to IMS to set the HW Accelerator configuration, which triggers a download and application of binaries from the SW Repo.](3f0d679c36471316685b4876ee7bb79d_img.jpg) + +``` + +sequenceDiagram + participant Personnel as Personnel +Cloud Installer + participant SMO as Service Management & Orchestration Framework +FOCOM + participant OCloud as O-Cloud +IMS + participant HAM + participant SWRepo as SW Repo + + Note over SMO: PRECONDITIONS: +SMO/FOCOM is active and running normally +O-Cloud is available +IMS is operational +HAM is operational and registered with the IMS +SMO and IMS connectivity is established +IMS and HAM connectivity is established +HW Accel(s) installed +HAM connection to HW Accel(s) is established + + Note over SMO: IMS informs SMO of the HW Accelerator Inventory +SMO Updates inventory with the HW Accelerator inventory information + + Note over SMO: 1 <<AALI-C-Mgmt>> aalInventoryNotification (inc SW/FW/Config - same params as getAalAccelInfo) + + Note over SMO: opt +If IMS needs to set the identifier of the HW Accel using the HW Accelerator vendor_name, model and serial_number input parameters. + + Note over SMO: 2 <<AALI-C-Mgmt>> setAalAccelIdentifier request + Note over OCloud: 3 <<AALI-C-Mgmt>> setAalAccelIdentifier response (success) + + Note over SMO: opt + Note over OCloud: 4 <<AALI-C-Mgmt>> getAalHwAccelStatus request + Note over OCloud: 5 <<AALI-C-Mgmt>> getAalHwAccelStatus response (success) + + Note over SMO: opt + Note over OCloud: 6 <<AALI-C-Mgmt>> getAalLpuStatus request + Note over OCloud: 7 <<AALI-C-Mgmt>> getAalLpuStatus response (success) + + Note over SMO: opt + Note over OCloud: 8 <<AALI-C-Mgmt>> getAalAccelInfo request + Note over OCloud: 9 <<AALI-C-Mgmt>> getAalAccelInfo response (success) + + Note over SMO: SMO optionally instructs IMS to configure HW Accelerator +boot image or other config/SW/config artifact + + Note over SMO: opt + Note over OCloud: If boot image or other config/SW/config artifact is needed or new driver is needed +(in order to match an intended configuration) then it is set using setAalAccelConfig API + Note over SMO: 10 <<AALI-C-Mgmt>> setAalAccelConfig request + Note over SWRepo: Download & apply needed binaries, images, FW, etc. + Note over OCloud: 11 <<AALI-C-Mgmt>> setAalAccelConfig response (success) + + Note over SMO: HW Accelerator is installed and SMO has the inventory +information about the HW Accelerator. +SMO inventory is updated +resource information + +``` + +Sequence diagram for end-2-end Life Cycle Management use case workflow. The diagram shows interactions between Personnel (Cloud Installer), Service Management & Orchestration Framework (FOCOM, IMS), O-Cloud (HAM), and SW Repo. The flow starts with preconditions, followed by a notification from IMS to FOCOM. Then, FOCOM sends a request to IMS to set the HW Accelerator identifier. This is followed by optional steps for getting status and configuration information. Finally, FOCOM sends a request to IMS to set the HW Accelerator configuration, which triggers a download and application of binaries from the SW Repo. + +### 4.2.2 end-2-end Life Cycle Management use case workflow (Informational) + +NOTE: The e2e flow depicted in this section are known to be incomplete and are being provided as informational guidance to implementors on how the APIs documented in the remainder of the specification are to be used. These exchanges will be made normative in future versions of the specification. + +This use case describes the end-to-end procedure with a focus on the interaction between the IMS and the HAM via the AALI-C-Mgmt interface for discovering the capabilities of the HW Accelerator, configuring the AAL-LPUs, instantiating an AAL Application and optionally updating/reconfiguring the managed resources based on the needs of the AAL Application. The flow also shows the interaction with the AAL Application via the AALI-C-App to create an AAL-Profile-Instance. + +This AAL UC flow can be executed during the O-Cloud Registration and Initialization Use Case, O-Cloud Inventory Update Use Case and the Hardware Infrastructure Scaling of O-Cloud Post Deployment Use Case [ Ref[5]: 3.1.3 “O-Cloud Registration and Initialization Use Case”, Configure AAL-LPU “3.1.4 : O-Cloud Inventory Update Use Case + +(DMS Example)” and “3.1.5: Hardware Infrastructure Scaling of O-Cloud Post Deployment”]. This use case is also related to the “3.2.1 Instantiate Network Function on O-Cloud”. + +**Table 4.2.2-1: end-2-end Life Cycle Management workflow steps** + +| | <b>Evolution / Specification</b> | <b><<Uses>><br/>Related use</b> | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------| +| Goal | Discover the capabilities of the HW Accelerator, update HW Accelerator and configure AAL-LPU(s) based on the AAL Application needs. | | +| Actors and Roles | SMO, FOCOM, NFO, IMS, DMS, HAM | | +| Assumptions | This UC can be applicable for initial or subsequent deployment of the O-Cloud, (re)instantiation of AAL Application and adding/deleting managed resources or AAL-Profile-Instances. | | +| Pre-conditions | <p>SMO/FOCOM/NFO is active and running normally</p> <p>O-Cloud is available</p> <p>IMS/DMS is operational</p> <p>HAM is operational and registered with the IMS</p> <p>HW Accelerator is bootstrapped/installed (4.2.1 HW Accelerator installation/bootstrap use case workflow).</p> <p>SMO and IMS/DMS communication is established</p> <p>IMS and HAM communication is established</p> <p>SMO Catalogue, AAL Application Manifest is available</p> <p>SW Repo available</p> <p>SMO inventory DB available</p> | | +| Begins when | SMO sends request to query the resource(s) | | +| Step 1-5 (M) | <p>SMO sends a query to retrieve the available O-Cloud resources Info.</p> <p>The IMS queries the HAM for the HW Accelerator managed resource(s) using the getAalAccelInfo via AALI-C-Mgmt interface. This includes hardware information and the HW accelerator capabilities (example: Vendor, Version, BIOS, AAL-LPU, and other capabilities supported by the HW Accelerator).</p> <p>SMO inventory is updated based on the response.</p> | | +| Step 6-10 (M) | <p>Based on the planned AAL Application manifest, the SMO/IMS configures the HW Accelerator (e.g.: AAL-LPU capabilities, Profile images etc) using the setAalAccelConfig via the AALI-C-Mgmt interface.</p> <p>The IMS receives inventory notifications for managed resources that have been added, modified or removed.</p> <p>DMS inventory is updated.</p> <p>SMO inventory is updated based on the response.</p> | | +| Step 11-20 (M) | SMO gets the deployment artifacts for AAL Application (e.g., Manifest/ Helm Charts) that includes requested O-Cloud Resource and profiles. SMO | | + +| | | | +|-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| | <p>then sends request to DMS for AAL Application instantiation with a manifest file.</p> <p>Using the setAalAccelConfig via the AALI-C-Mgmt interface the HW Accelerator and AAL-LPU configuration may have to be updated as needed for each of the items in the manifest.</p> <p>The IMS receives receive inventory notifications for managed resources that have been added, modified or removed.</p> <p>The AAL Application is instantiated, and the DMS/SMO inventory updated. [5].</p> | | +| Step 21-22 (M) | The SMO configures the cell details, AAL Profile versions etc to the AAL Application via O1 interface | | +| Step 23 (M) | Initialize AALI-C-App interface between the AAL Application and the AAL | | +| Step 24-25 (M) | <p>The AAL Application queries through the AALI-C-App interface the AAL implementation to get the capabilities of the AAL-LPU assigned using the getAalLpuInfo via the AALI-C-App interface.</p> <p>In response, the AAL Application gets the aal-lpu-handle and the AAL Profile(s) supported.</p> | | +| Step 26-33 (M) | The AAL Application creates one or many AAL-Profile-Instance(s) via the AALI-C-App using setAalProfileInstance and starts the AAL-Profile-Instance. The AAL Application also sets the AAL-Profile-Queue configuration and starts the queue. | | +| Step 34-39 (M) | If the AAL-Profile-Instance needs to be updated or is not needed anymore, the AAL Application via the AALI-C-App stops the AAL-Profile-Queue and AAL-Profile-Instance and deletes the AAL-Profile-Instance. | | +| Ends when | The HW Accelerator and AAL-LPUs have been configured, the AAL Application is instantiated and the AAL Profile instances are managed. | | +| Exceptions | None identified | | +| Post Conditions | AAL Application is instantiated, and the AAL-Profile-Instances are managed. | | +| Traceability | To be added later | | + +#### 4.2.2.1 Sequence Diagram + +``` + +@startuml +skinparam sequenceArrowThickness 1 +skinparam ParticipantPadding 2 +skinparam BoxPadding 5 +Autonumber + +Box "Service Management & Orchestration Framework" #gold + Participant "FOCOM/NFO" as FCC +End box + +Box "O-Cloud" #lightseagreen + Participant "IMS" as IMS + Participant DMS as "DMS" + Participant HAM as "HAM" + Participant "AAL \n Implementation" as aal +End box + +``` + +``` + +Box "Network Functions"#LightBlue + Participant "<<AAL-App>> AAL Application" as App +End box + +Box "Network Functions"#DarkBlue + Participant "SMO" as O1 +End box + +Box "SW Repo" "#Blue + Participant "Repo" as Repo +End box + +Note over FCC, DMS + PRECONDITIONS: + SMO/FOCOM/NFO is active and running normally + O-Cloud is available + IMS/DMS is operational + HAM is operational and registered with the IMS + HW Accelerator is bootstrapped/installed + SMO and IMS/DMS connectivity is established + IMS and HAM connectivity is established + +End Note +== Use case: AAL Flow == + +Note over FCC + PRECONDITIONS: + SMO Catalog, HW Accelerator Manifest, AAL Application Manifest available + FW/SW image Repo available, SMO inventory DB available +End Note + +FCC -> IMS: <<O2>> QueryOcloudInfoRequest +IMS -> HAM : <<AALI-C-Mgmt>> getAalAccelInfo +HAM --> IMS : getAalAccelInfo response Success( Vendor, Version, Bios etc ) +IMS --> FCC : <<O2>> QueryOcloudInfoResponse +FCC -> FCC : SMO inventory updated + +Note over FCC, IMS + Single Set command to configure the device with manifest, + including AAL LPU and Profile Images. + The SMO knows the pre-defined set of configurations that support different + use cases that it wants to deploy. + The configuration can be changed dynamically in the future. + The HAM will be able to apply delta changes accordingly. +end Note + +group Set configuration of the HW Accelerator + +Note over FCC, IMS + SMO triggers configuration of the HW Accelerator +End Note +IMS -> HAM: <<AALI-C-Mgmt>> setAalAccelConfig \n(e.g. AAL-LPU's, Supported AAL-Profile +etc..) +Note over HAM, Repo + Optionally, the SW/FW image is retrieved from the Software Repository +End Note + +group DMS inventory update +HAM <--> DMS : DMS Info exchange +Note over DMS + Examples of information exchanged \n AAL-LPUs, AAL-Profile info etc +End Note +End + +HAM --> IMS: setAalAccelConfig response success +HAM --> IMS : <<AALI-C-Mgmt>> aalInventoryNotification w/ managed resource informaton + +Note over FCC, IMS + +``` + +``` + +Response to SMO with success/failure of setting AAL Accel Config +end Note +FCC -> FCC : SMO inventory update +end + +group Instantiate AAL Applications and optionally update HW Accelerator information +Note over FCC,IMS + SMO Instantiate AAL Applications + SMO gets the deployment artifacts for + containerized workload (e.g., Manifest/ Helm Charts). + This includes managed resource and AAL-Profiles requested +end Note +REF over FCC : Use case 3.2.1 Orchestration Use Case Spec +FCC -> DMS : <<O2>> Instantiate AAL Application +Note over DMS + The DMS manifest includes the LPU (Profile) required and I/O ports etc.. +end NOTE + +opt Update HW Accelerator information if needed +Note over DMS + Optionally, the IMS sets the AAL Accel Config + based on the information received from SMO + to add/modify managed resources as defined in the AAL Application instantiate request. +End Note +DMS --> FCC : <<DMS-SMO interface>>Update HW Accelerator information(to be define by +O2dms) +FCC -> IMS: <<O2>> setAalAccelConfig \n(including AAL-LPU's, Supported AAL-Profile) +IMS -> HAM: <<AALI-C-Mgmt>> setAalAccelConfig \n(e.g. AAL-LPU's, Supported AAL-Profile) +HAM --> IMS: <<AALI-C-Mgmt>> setAalAccelConfig response success +HAM --> IMS : <<AALI-C-Mgmt>> aalInventoryNotification w/ O-Cloud AAL-LPU information +IMS --> FCC : <<O2>> Set AAL Accel Config response success + +FCC --> DMS: Success + +End opt + +DMS -> App : <<AAL-App>> AAL Application instantiated +activate App +DMS --> FCC : <<AAL-App>> AAL Application instantiated response success +End + +group AAL Application application and AAL configured +O1 -> App : <<O1>> DU Configuration \n Cells, BW, Profile Version etc.. +App --> O1 : response Success +Note over aal, App + Initilize the AAL interface betwwen AAL and the AAL Application +end NOTE +App <-> aal : Init AALI-C-App + +Note over aal, App + Get AAL LPU information and + create AAL Profile Instance +end NOTE +App -> aal : <<AALI-C-App>> getAalLpuInfo + +aal -> App : <<AALI-C-App>> Response LPU/Profile handle + +App -> aal : <<AALI-C-App>> createAalProfileInstance +aal -> App : <<AALI-C-App>> Response Success + +App -> aal : <<AALI-C-App>> +setAalProfileInstance/startAalProfileInstance/startAalProfileInstance +aal -> App : <<AALI-C-App>> Response Success + +App -> aal : <<AALI-C-App>> setAalProfileQueueConfig +aal -> App : <<AALI-C-App>> Response Success + +App -> aal : <<AALI-C-App>> startAalProfileQueue +aal -> App : <<AALI-C-App>> Response Success + +``` + +``` +Note over aal, App +Delete AAL Profile Instance +end NOTE + +App -> aal : <<AALI-C-App>> stopAalProfileQueue +aal -> App : <<AALI-C-App>> Response Success + +App -> aal : <<AALI-C-App>> stopAalProfileInstance +aal -> App : <<AALI-C-App>> Response Success + +App -> aal : <<AALI-C-App>> deleteAalProfileInstance +aal -> App : <<AALI-C-App>> Response Success +end +== End Use Case == + +@enduml +``` + +![Sequence diagram for HW Accelerator Manager (HAM) registration use case workflow. The diagram shows interactions between Service Management & Orchestration Framework (FQDN: FQDN), O-Cloud (IMS, DMS, HAM, AAL Implementation), Network Functions (AAL-App), SMO, and Repo. The workflow includes preconditions, use case AAL Flow, setting configuration of the HW Accelerator, instantiating AAL applications, and AAL application application and AAL configured steps.](91bf418f53337d71e80fdb42ab0776c5_img.jpg) + +**Service Management & Orchestration Framework** + +**O-Cloud** + +**Network Functions** + +**SMO** + +**Repo** + +**Use case: AAL Flow** + +**Set configuration of the HW Accelerator** + +**Instantiate AAL applications and optionally update HW Accelerator information** + +**AAL application application and AAL configured** + +**End Use Case** + +**Preconditions:** + +- SMO/FQDN is active and running normally +- O-Cloud is available +- IMS/DMS is operational +- HAM is operational and registered with the IMS +- HW Accelerator is bootstrapped/installed +- SMO and IMS/DMS connectivity is established +- IMS and HAM connectivity is established + +**Use case: AAL Flow** + +**Preconditions:** + +- SMO Catalog, HW Accelerator Manifest, AAL application Manifest available +- FW/FW image Repo available, SMO inventory DB available + +**Set configuration of the HW Accelerator** + +SMO triggers configuration of the HW Accelerator + +1 <<O2>> QueryO2ConfigRequest + +2 <<AAL-C-Mgmt>> getAalAccelInfo + +3 getAalAccelInfo response Success (Vendor, Version, Bios etc.) + +4 <<O2>> QueryO2ConfigResponse + +5 SMO inventory update + +Single Set command to configure the device with manifest, including AAL LPU and Profile Images. The SMO knows the predefined set of configurations that support different use cases that it wants to deploy. The configuration can be changed dynamically in the future. The HAM will be able to apply delta changes accordingly. + +6 <<AAL-C-Mgmt>> setAalAccelConfig (e.g. AAL-LPU's, Supported AAL-Profile etc.) + +7 DMS Info exchange + +Examples of information exchanged to AAL-LPU's, AAL-Profile info etc. + +8 setAalAccelConfig response success + +9 <<AAL-C-Mgmt>> aalInventoryNotification w/ O-Cloud resource information + +Response to SMO with success/failure of setting AAL Accel Config + +10 SMO inventory update + +Optionally, the SW/FW image is retrieved from the Software Repository + +**Instantiate AAL applications and optionally update HW Accelerator information** + +SMO Instantiate AAL applications. SMO gets the deployment artifacts for containerized workload (e.g., Manifest/ Helm Charts). This includes resource and profiles requested. + +Use case 3.2.1 Orchestration Use Case Spec + +11 <<O2>> Instantiate AAL application + +The DMS manifest includes the LPU (Profile) required and I/O ports etc. + +[Update HW Accelerator information if needed] + +12 <<DMS-SMO interface>> Update HW Accelerator information to be define by O2dms + +13 <<O2>> setAalAccelConfig (including AAL-LPU's, Supported AAL-Profile) + +14 <<AAL-C-Mgmt>> setAalAccelConfig (e.g. AAL-LPU's, Supported AAL-Profile) + +15 <<AAL-C-Mgmt>> setAalAccelConfig response success + +16 <<AAL-C-Mgmt>> aalInventoryNotification w/ O-Cloud AAL-LPU information + +17 <<O2>> Set AAL Accel Config response success + +18 Success + +19 <<AAL-App>> AAL application instantiated + +20 <<AAL-App>> AAL application instantiated response success + +**AAL application application and AAL configured** + +Initialize the AAL interface between AAL and the AAL Application + +21 <<O1>> DU Configuration Cells, BW, Profile Version etc. + +22 response Success + +23 Init AAL-C-App + +Get AAL LPU information and create AAL Profile Instance + +24 <<AAL-C-App>> getAalLpuInfo + +25 <<AAL-C-App>> Response LPU/Profile handle + +26 <<AAL-C-App>> createAalProfileInstance + +27 <<AAL-C-App>> Response Success + +28 <<AAL-C-App>> setAalProfileInstance/startAalProfileInstance/startAalProfileInstance + +29 <<AAL-C-App>> Response Success + +30 <<AAL-C-App>> setAalProfileQueueConfig + +31 <<AAL-C-App>> Response Success + +32 <<AAL-C-App>> startAalProfileQueue + +33 <<AAL-C-App>> Response Success + +Delete AAL Profile Instance + +34 <<AAL-C-App>> stopAalProfileQueue + +35 <<AAL-C-App>> Response Success + +36 <<AAL-C-App>> stopAalProfileInstance + +37 <<AAL-C-App>> Response Success + +38 <<AAL-C-App>> deleteAalProfileInstance + +39 <<AAL-C-App>> Response Success + +Sequence diagram for HW Accelerator Manager (HAM) registration use case workflow. The diagram shows interactions between Service Management & Orchestration Framework (FQDN: FQDN), O-Cloud (IMS, DMS, HAM, AAL Implementation), Network Functions (AAL-App), SMO, and Repo. The workflow includes preconditions, use case AAL Flow, setting configuration of the HW Accelerator, instantiating AAL applications, and AAL application application and AAL configured steps. + +### 4.2.3 HW Accelerator Manager (HAM) registration use case workflow + +The HAM registration procedure makes the HAM known to the IMS. + +This use case describes how the HAM registers itself with the IMS using the AALI-C-Mgmt API. This registration at the minimum includes the HAM end point for the IMS to communicate with the HAM. + +Following successful registration with the IMS, the HAM can participate in other resource management and AALI-C-Mgmt procedures. + +Until successfully registered with an IMS, the HAM cannot accept management requests or provide notifications not associated with the IMS registration procedure. + +NOTE: Installation and configuration of the HAM are not in the scope of this use case. How the HAM is configured with the IMS service endpoint and the local HAM service endpoint are implementation specific. + +**Table 4.2.3-1: HW Accelerator Manager registration workflow steps** + +| | Evolution / Specification | <<Uses>><br>Related use | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | Register the HW Accelerator Manager (HAM) with the IMS | | +| Actors and Roles | SMO, FOCOM, IMS, HAM | | +| Assumptions | This UC is applicable when the HAM is first configured with the IMS and HAM service endpoints or when the IMS or HAM service endpoint is modified. | | +| Pre-conditions | SMO/FOCOM is active and running normally<br><br>O-Cloud is available<br><br>IMS is operational and reachable.<br><br>HAM is configured and not registered with the IMS<br><br>SMO and IMS connectivity is established | | +| Begins when | When the HAM is ready to register with the IMS | | +| Step 1 (M) | HAM initialized | | +| Step 2 (M) | HAM registers itself with the IMS | | +| Step 3 (M) | IMS sends a success response to the HAM | | +| Ends when | The IMS updates its inventory for the availability of the HAM | | +| Exceptions | None identified | | +| Post Conditions | IMS can communicate with the HAM via its end point | | +| Traceability | To be added later | | + +#### 4.2.3.1 Sequence Diagram + +``` +@startuml +``` + +``` +skinparam sequenceArrowThickness 1 +skinparam ParticipantPadding 2 +skinparam BoxPadding 5 +Autonumber +``` + +``` + +Box "Service Management & Orchestration Framework" #gold + Participant "FOCOM" as FCC +End box + +Box "O-Cloud" "#lightseagreen" + Participant "IMS" as IMS + Participant AccelMgr as "HAM" +End box + +Note over FCC,AccelMgr + HAM was is installed and configured with the IMS service endpoint +End Note + +AccelMgr --> AccelMgr : HAM is configured and not registered with the IMS + +AccelMgr --> IMS : <<AALI-C-Mgmt>> aalHamRegistrationNotification (Registration +Notification.callback URI) +IMS --> AccelMgr : <<AALI-C-Mgmt>> response (sucess) + +Note over IMS + IMS update its inventory +End Note + +Note over FCC, IMS + TBD * IMS informs SMO of the HW Accelerator Manager (HAM) Inventory + SMO Updates inventory with the HAM inventory information * +End Note + +@endum1 + +``` + +![Sequence diagram showing interactions between FOCOM, IMS, and HAM. FOCOM sends a message to IMS: 'HAM was is installed and configured with the IMS service endpoint'. IMS sends a message to HAM: '1 HAM is configured and not registered with the IMS'. HAM sends a message to IMS: '2 <<AALI-C-Mgmt>> aalHamRegistrationNotification (Registration Notification.callback URI)'. IMS sends a message to HAM: '3 <<AALI-C-Mgmt>> response (sucess)'. IMS sends a message to FOCOM: 'IMS update its inventory'. FOCOM sends a message to IMS: 'TBD * IMS informs SMO of the HW Accelerator Manager (HAM) Inventory SMO Updates inventory with the HAM inventory information *'.](467037c727838a5ac6cbaebd45a5c64d_img.jpg) + +``` + +sequenceDiagram + participant FOCOM + participant IMS + participant HAM + + FOCOM->>IMS: HAM was is installed and configured with the IMS service endpoint + IMS->>HAM: 1 HAM is configured and not registered with the IMS + HAM->>IMS: 2 <<AALI-C-Mgmt>> aalHamRegistrationNotification (Registration Notification.callback URI) + IMS->>HAM: 3 <<AALI-C-Mgmt>> response (sucess) + IMS->>FOCOM: IMS update its inventory + FOCOM->>IMS: TBD * IMS informs SMO of the HW Accelerator Manager (HAM) Inventory SMO Updates inventory with the HAM inventory information * + +``` + +Sequence diagram showing interactions between FOCOM, IMS, and HAM. FOCOM sends a message to IMS: 'HAM was is installed and configured with the IMS service endpoint'. IMS sends a message to HAM: '1 HAM is configured and not registered with the IMS'. HAM sends a message to IMS: '2 <> aalHamRegistrationNotification (Registration Notification.callback URI)'. IMS sends a message to HAM: '3 <> response (sucess)'. IMS sends a message to FOCOM: 'IMS update its inventory'. FOCOM sends a message to IMS: 'TBD \* IMS informs SMO of the HW Accelerator Manager (HAM) Inventory SMO Updates inventory with the HAM inventory information \*'. + +## 4.3 AALI-C-Mgmt API details + +NOTE: The AALI-C-Mgmt interface defines the administrative operations/actions/events between the O-Cloud IMS and the HAM. + +### 4.3.1 Capabilities discovery and configuration + +#### 4.3.1.1 getAalHwAccelStatus + +Description: This API is used to query the HAM about the status of the HW Accelerator. + +Pre-conditions: HAM is registered with an IMS. + +Triggers: On demand request via AALI-C-Mgmt interface + +Frequency: N/A + +**Table 4.3.1.1-1: getAalHwAccelStatus Operation** + +| Operation | Direction | +|---------------------|-------------------------------------| +| getAalHwAccelStatus | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.1.1-2: getAalHwAccelStatus Input Parameter** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|------------------------------------| +| hw_accel_id | | Identifier | M | This ID is unique within a O-Cloud | + +**Table 4.3.1.1-3: getAalHwAccelStatus Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------------------|-------------|-----------------------------------------|-----------|--------------------------------------------------------------------------------------------| +| hw_accel_operational_state | | <i>String</i> | M | Returns the operational state of the HW Accelerator | +| hw_accel_operational_conditions | 0..N | <i>Array</i> | M | Returns the operation conditions that support the operational state of the HW Accelerator. | +| status_of_operation | 1 | <i>Reference<br/>WG6 info<br/>model</i> | M | Returns the status of the operation | + +#### 4.3.1.2 getAalLpuStatus + +Description: + +This API is used to query the HAM about the status of the HW Accelerator and the AAL-LPUs (per AAL-LPU).). + +Pre-conditions: HAM is registered with an IMS. + +Triggers: On demand request via AALI-C-Mgmt interface + +Frequency: N/A + +**Table 4.3.1.2-1: getAalLpuStatus Operation** + +| Operation | Direction | +|-----------------|-------------------------------------| +| getAalLpuStatus | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.1.2-2: getAalLpuStatus Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|-------------------------------------| +| hw_accel_id | 1.. N | Identifier | M | This ID is unique within an O-Cloud | + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|-------------------------------------------| +| aal_lpu_handle | 0..1 | Identifier | M | This ID is unique within a HW Accelerator | + +**Table 4.3.1.2-3: getAalLpuStatus Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------------------|-------------|--------------------------------|-----------|------------------------------------------------------------------------------------| +| hw_accel_id | 1.. N | Identifier | M | This ID is unique within an O-Cloud | +| >aal_lpu_handle | 1 | Identifier | M | This ID is unique within a HW Accelerator | +| >aal_lpu_operational_state | 1 | String | M | Returns the operational state of the AAL-LPU. | +| >aal_lpu_operational_conditions | 0..N | Array | M | Returns the operation conditions that support the operational state of the AAL-LPU | +| status_of_operation | 1 | Reference<br>WG6 info<br>model | M | Returns the status of the operation | + +#### 4.3.1.3 getAalAccelInfo + +Description: This API is used to query the HAM about a HW Accelerator and capabilities of its AAL-LPU(s). + +Pre-conditions: HAM is registered with an IMS. + +. + +Triggers: On demand request via AALI-C-Mgmt interface + +Frequency: N/A + +**Table 4.3.1.3-1: getAalAccelInfo Operation** + +| Operation | Direction | +|-----------------|-------------------------------------| +| getAalAccelInfo | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.1.3-2: getAalAccelInfo Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|-----------------------------------------------------------| +| hw_accel_id | 1.. N | Identifier | M | Unique Identification of the AAL-HW-Accel in the O-Cloud. | + +| Output Parameter | Cardinality | Data Type<br>(Align with<br>O2 Data<br>model) | Qualifier | Description | +|---------------------|-------------|-----------------------------------------------|-----------|--------------------------------------------------------| +| status_of_operation | 1 | Reference<br>WG6 info<br>model | M | Returns the status of the get-AAL-Accel-info procedure | + +| Output Parameter | Cardinality | Data Type<br>(Align with O2 Data model) | Qualifier | Description | +|----------------------------------|-------------|-----------------------------------------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| hw_accel_list | 0.. N | List of struct - inlined | M | List of Hardware Accelerator's and their characteristics: | +| >hw_accel_id | 1 | Identifier | M | Unique Identification of the HW Accelerator in the O-Cloud. | +| >hw_accel_operational_state | 1 | String | M | The operational state of the HW Accelerator | +| >hw_accel_operational_conditions | 1 | Array | M | The operational conditions that support the operational state of the HW Accelerator | +| >vendor_name | 1 | String | M | Name of the Vendor/Provider of the resource. | +| >date_of_manufacture | 1 | String | M | Date of the manufacture of the resource. | +| >model | 1 | String | M | Information about the model of the resource. | +| >serial_number | 1 | String | M | Serial number of the specific resource. | +| >hw_version | 1 | String | M | Version or generation of the resource. | +| >hw_accel_image_version | 1 | String | M | The version for the image applied to the HW Accelerator. The parameter is associated with the HW Accelerator's resource type. | +| >hw_accel_image_location | 1 | String | M | Path / URI to the software/firmware image. | +| >hw_accel_vendor_specific | 0.. N | List Key Value Pair<br>String/String | M | Vendor specific attributes associated with the HW Accelerator. | +| >max_num_aal_lpus | 0..1 | Integer | O | This parameter may be included if a HW Accelerator has an upper limit on AAL-LPUs it can support. Actual number of AAL-LPUs available at runtime may be lower based on resource usage, AAL-LPU SW used, and AAL-Profile SW and types instantiated on the AAL-LPU(s) | +| >aal_profile_templates | 0..N | List AALProfileTemplate | M | This parameter provides a list of templates for the AAL-Profiles that is supported for this HW Accelerator. | +| >num_aal_lpus_configured | 1 | Integer | M | Number of LPU(s) configured | + +| Output Parameter | Cardinality | Data Type<br>(Align with O2 Data model) | Qualifier | Description | +|----------------------------------|-------------|-----------------------------------------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| >lpu_type | 1 | String | M | single/mixed<br><br>single: all LPUs are identical.<br><br>mixed: non-identical LPUs | +| >aal_lpu_list | 0.. N | List of struct - inlined | M | List of AAL-LPUs and their characteristics: | +| >> aal_lpu_handle | 1 | Identifier | M | Uniquely identifies the AAL-LPU within the accelerator | +| >>aal_lpu_administrative_state | 1 | String | M | The administrative state of the AAL-LPU | +| >>aal_lpu_operational_state | 1 | String | M | The operational state of the AAL-LPU | +| >>aal_lpu_operational_conditions | 1 | Array | M | The operational conditions that support the operational state of the AAL-LPU. | +| >>aal_lpu_image_version | 1 | String | M | The version or generation for the image applied to the AAL-LPU.<br><br>If an AAL-LPU image is the same as the Accelerator HW image then the hw_accel_image_version and aal_lpu_image_version parameters would contain the same value. | +| >>aal_lpu_image_location | 1 | String | M | Path / URI to the software/firmware image.<br><br>If an AAL-LPU image is the same as the Accelerator HW image then the hw_accel_image_location and aal_lpu_image_location parameters would contain the same value. | +| >>aal_lpu_profile_list | 0..1 | List of Struct - inlined | M | List of AAL-Profile(s) supported (Profile Name ID, Image) | +| >>>aal_lpu_profile_name | 1 | String | M | AAL Profile name as defined in section 3.3.3.1. | +| >>>aal_lpu_profile_version | 1 | String | M | AAL Profile version for the associated AAL Profile name. The AAL Profile version is the version of the AAL Profile's approved specification. | +| >>>aal_lpu_profile_image_version | 1 | String | M | Version of the AAL Profile image (e.g. binaries, libraries, etc).<br><br>If an AAL Profile image is the same as the AAL-LPU image then the aal_lpu_image_version and aal_lpu_profile_image_version parameters would contain the same value. | + +| Output Parameter | Cardinality | Data Type<br>(Align with O2 Data model) | Qualifier | Description | +|------------------------------------|-------------|------------------------------------------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| >>>aal_lpu_profile_image_location | 1 | String | M | Path / URI to the AAL Profile image (e.g. binaries, libraries, etc).<br><br>If an AAL Profile image is the same as the AAL-LPU image then the aal_lpu_image_location and aal_lpu_profile_image_location parameters would contain the same value. | +| >>>aal_lpu_profile_attributes | 0..N | List Key Value Pair | M | This parameter provides a list of configuration attributes for the AAL-Profiles that used for this AAL-LPU. The structure and format of the Value attribute is specified as part of the definition of the Key. | +| >>>aal_lpu_profile_vendor_specific | 0..N | List Key Value Pair | M | This parameter provides a list of vendor specific attributes for the AAL-Profiles that used for this AAL-LPU. The structure and format of the Value attribute is specified as part of the definition of the Key. | +| >>aal_lpu_config | 0..1 | Struct - Inlined | M | Can be one or more parameters that define the AAL-LPU persona – Some of the parameters are listed below | +| >>>aal_lpu_memory | 0..1 | Integer | O | AAL-LPU memory | +| >>>aal_lpu_multi_processors_num | 0..1 | Integer | O | Number of Multi-Processors per AAL-LPU | +| >>>aal_lpu_compute_slices_num | 0..1 | Integer | O | Number of compute slices per AAL-LPU | +| >>aal_lpu_vendor_specific | 0.. N | List Key Value Pair<br><br>String/String | M | Vendor specific AAL-LPU attribute.<br><br>Some examples: Number of DMA engines, number of encoders, number of decoders, number of JPEG engines, Number of OfA (Optical flow accelerator) engines | + +NOTE: While this list provides the details of parameters between IMS and HAM, further analysis is needed to understand what is needed by the SMO. + +#### 4.3.1.4 setAalAccelConfig + +Description: This is used to configure the HW Accelerator and AAL-LPU. The operation's input parameters are the full configuration set of parameters for the HW Accelerator and contained AAL-LPUs. These input parameters replace the existing configuration of the HW Accelerator and AAL-LPUs. The HAM shall determine the changes to be applied to the HW Accelerator based on the input parameters contained in the operation and the current configuration parameters associated with the HW Accelerator. For example, if the operation contains an AAL-LPU instance that is part of the current configuration, the HAM adds the AAL-LPU instance to the current configuration. Likewise, if the current configuration has a configured AAL-LPU that is not contained within the input parameters of this operation, the HAM + +deletes the AAL-LPU from the current configuration of the HW Accelerator. The HAM shall validate the state of the HW Accelerator and AAL-LPUs prior to applying the changes. + +Pre-conditions: + +- HW Accelerator Device is initialized, and HAM is operational. +- HW Accelerator Device and AAL-LPUs are in the correct state prior to performing configuration changes. + +Triggers: On demand request via AALI-C-Mgmt interface + +Frequency: N/A + +**Table 4.3.1.4-1: setAalAccelConfig Operation** + +| Operation | Direction | +|-------------------|-------------------------------------| +| setAalAccelConfig | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.1.4-2: setAalAccelConfig Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|----------------------------------|-------------|--------------------------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| hw_accel_list | 1.. N | List of struct - inlined | M | List of Hardware Accelerator's and their characteristics: | +| >hw_accel_id | 1.. N | Identifier | M | Unique Identification of the AAL-HW-Accel in the O-Cloud.. | +| >hw_accel_image_version_location | 1 | String | M | Path / URI to the HW Accelerator image (e.g., BIOS/FW/Host OS, libraries, drivers) to be used. | +| >num_aal_lpus_configured | 1 | Integer | M | Number of LPU(s) configured | +| >lpu_type | 1 | String | M | single/mixed<br>single: all LPUs are identical.<br>mixed: non-identical LPUs | +| >aal_lpu_list | 0.. N | List of struct - inlined | M | List of AAL-LPUs and their characteristics: | +| >> aal_lpu_handle | 1 | Identifier | M | Uniquely identifies the AAL-LPU within the accelerator | +| >>aal_lpu_image_version_location | 1 | String | M | Path / URI to the Image (e.g. FW/guest OS, libraries, drivers) to be used.<br><br>If an AAL-LPU image is the same as the Accelerator HW image then the hw_accel_image_version_location and | + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|------------------------------------|-------------|--------------------------------------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | aal_lpu_image_version_location parameters would contain the same value | +| >hw_accel_vendor_specific | 0..N | List Key Value Pair<br>String/String | M | Vendor specific attributes associated with the HW Accelerator. | +| >>aal_lpu_profile_list | 0..N | List of Struct - inlined | M | List of AAL-Profile(s) supported (Profile Name ID, Image) | +| >>>aal_lpu_profile_name | 1 | String | M | AAL Profile name as defined in section 3.3.3.1. | +| >>>aal_lpu_profile_version | 1 | String | M | AAL Profile version for the associated AAL Profile name. The AAL Profile version is the version of the AAL Profile's approved specification | +| >>>aal_lpu_profile_image_version | 1 | String | M | Version of the AAL Profile image (e.g. binaries, libraries, etc).<br><br>If an AAL Profile image version is the same as the aal_lpu_image_version then the aal_lpu_image_version and aal_lpu_profile_image_version parameters would contain the same value. | +| >>>aal_lpu_profile_image_location | 1 | String | M | Path / URI to the AAL Profile image (e.g. binaries, libraries, etc) to be used.<br><br>If an AAL Profile image is the same as the AAL-LPU image then the aal_lpu_image_version_location and aal_lpu_profile_image_location parameters would contain the same value. | +| >>>aal_lpu_profile_attributes | 0..N | List Key Value Pair | M | This parameter provides a list of configuration attributes for the AAL-Profiles that used for this AAL-LPU. The structure and format of the Value attribute is specified as part of the definition of the Key. | +| >>>aal_lpu_profile_vendor_specific | 0..N | List Key Value Pair | M | This parameter provides a list of vendor specific attributes for the AAL-Profiles that used for this AAL-LPU. The structure and format of the Value attribute is specified as part of the definition of the Key. | +| >>aal_lpu_config | 0..1 | Struct - Inlined | M | Can be one or more parameters that define the AAL-LPU persona – Some of the parameters are listed below | +| >>aal_lpu_memory | 0..1 | Integer | O | AAL-LPU memory | +| >>aal_lpu_multiprocessors_num | 0..1 | Integer | O | Number of Multi-Processors per AAL-LPU | + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|------------------------------|-------------|--------------------------------------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| >>aal_lpu_compute_slices_num | 0..1 | Integer | O | Number of compute slices per AAL-LPU | +| >>aal_lpu_vendor_specific | 0.. N | List Key Value Pair<br>String/String | M | Vendor specific AAL-LPU attribute. Some examples: Number of DMA engines, number of encoders, number of decoders, number of JPEG engines, Number of OfA (Optical flow accelerator) engines | + +**Table 4.3.1.4-3: setAalAccelConfig Output Parameter** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|-----------------------------------------|-----------|-------------------------------------| +| status_of_operation | | <i>Reference<br/>WG6 info<br/>model</i> | M | Returns the status of the procedure | + +- The vendor specific attributes in the getAalAccelInfo and setAalAccelConfig needs to consider vendor specific attributes for the LPU and Accelerator. + +#### 4.3.1.5 startAalLpu + +Description: This operation will start an AAL-LPU that is in the stopped state. The AAL-LPU is instantiated using the SW/FW image(s) and configuration that were provided in the setAalAccelConfig procedure. + +The AAL-LPU state machine is moved to a started state. When the AAL-LPU is in the started state it is ready to be used by the AAL Application. + +After successfully starting AAL-LPU using this procedure, the AAL-LPU can be stopped. + +Pre-conditions: HW Accelerator Device is initialized, and HAM is operational. The AAL-LPU has been successfully configured and is in the stopped state. + +Triggers: On demand request via AALI-C-Mgmt interface + +Frequency: N/A + +**Table 4.3.1.5-1: startAalLpu Operation** + +| Operation | Direction | +|-------------|-------------------------------------| +| startAalLpu | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.1.5-2: startAalLpu Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|--------------------------------------------------| +| hw_accel_id | 1 | Identifier | M | HW Accel ID is unique within an O-Cloud | +| aal_lpu_handle | 1 | Identifier | M | AAL-LPU handle is unique within a HW Accelerator | + +**Table 4.3.1.5-3: startAalLpu Output Parameter** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|-----------------------------------------|-----------|-------------------------------------| +| status_of_operation | 1 | <i>Reference<br/>WG6 info<br/>model</i> | M | Returns the status of the procedure | + +#### 4.3.1.6 stopAalLpu + +Description: Moves AAL-LPU state machine to a stopped state. + +AAL-LPU service is stopped. Configuration changes on the AAL-LPU can be performed. Re-configuration of the AAL-LPU compute / memory resource partitioning can be performed. Drivers can be updated / re-installed and configured. Maintenance / debugging operations can be performed. + +After successfully stopping the AAL-LPU, the AAL-LPU can be (re-)configured, started or deleted. + +Pre-conditions: HW Accelerator Device is initialized, and HAM is operational. The number of AAL-LPUs has been set on the HW Accelerator. The AAL-LPU has been successfully configured and is started. AAL Applications have previously been migrated off the AAL-LPU. + +Triggers: On demand request via AALI-C-Mgmt interface + +Frequency: N/A + +**Table 4.3.1.6-1: stopAalLpu Operation** + +| Operation | Direction | +|------------|-------------------------------------| +| stopAalLpu | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.1.6-2: stopAalLpu Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|-------------------------------------------| +| hw_accel_id | 1 | Identifier | M | This ID is unique within an O-Cloud | +| aal_lpu_handle | 1 | Identifier | M | This ID is unique within a HW Accelerator | + +**Table 4.3.1.6-3: stopAalLpu Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|--------------------------------------------|-----------|-------------------------------------| +| status_of_operation | 1 | <i>Reference<br/>WG10<br/>object model</i> | M | Returns the status of the procedure | + +#### 4.3.1.7 Inventory Notifications + +Description: Inventory notifications are sent by the HAM to the IMS when the HAM discovers that managed resources have been added, modified, or removed from the HAM's inventory of managed resources. Inventory notifications are not used to report administrative or operational state changes in the resources (e.g., restarts, configuration changes that do not include added or deleted managed resources). The Inventory Notification services in this section, provide the ability for the IMS to receive inventory notification events when managed resources have been added, modified or removed from the HAM. + +The modification of a managed resource differs from addition and removal of an O-Cloud Resource. Examples of modifications of a managed resource that causes an Inventory Notification event to be emitted by the HAM would be the modification of the path to the image for an AAL-LPU or the modification of the compute resources assigned to the AAL-LPU.. + +##### 4.3.1.7.1 aalInventoryNotification + +Description: The HW Accelerator Manager emits notifications to the IMS. The 4.2.1 HW Accelerator installation/bootstrap use case workflow, 4.2.2 end-2end Life Cycle Management use case workflow (Informational) provide examples of when the inventory notification is sent by the HAM to the IMS that has previously subscribed to receive the notification event. + +Pre-conditions: The HAM is operational. The IMS and the HAM have established connectivity. + +Triggers: On demand request via AALI-C-Mgmt interface. + +Frequency: Infrequent + +**Table 4.3.1.7-1: aalInventoryNotification Operation** + +| Operation | Direction | +|--------------------------|-------------------------------------| +| aalInventoryNotification | HW Accelerator Manager (HAM) => IMS | + +**Table 4.3.1.7-2: aalInventoryNotification Parameters** + +| Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|-------------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| resources | 0.. N | Structure | M | The current managed resource list. | +| > resource | 1 | Structure | M | The resource (HW Accelerator, AAL-LPU) and its associated attributes known by the HAM.<br><br>Section 3.3.1 contains the list of attributes for managed resource that are retrieval and are part of the Inventory Notification event.<br><br>When the HW Accelerator is newly discovered, the hw_accel_id attribute of the resource does not have a value reported since the value of this attribute is assigned by the IMS. | +| > detected_time | 1 | DateTime | M | The time the inventory event was last detected. | +| > event | 1 | Enumeration | M | The event that caused the notification.<br><br>Values: Add, Modify, Remove | + +#### 4.3.1.8 setAalAccelIdentifier + +Description: This is used to provide the HW Accelerator with its resource identifier (hw\_accel\_id) assigned by the IMS. The HAM uses the vendor, model, and serial\_number input parameters to identify the HW Accelerator and then assigns the resource identifier to the HW Accelerator. + +Pre-conditions: HW Accelerator has been discovered but needs its identifier assigned by the IMS, and HAM is operational. + +Triggers: On demand request via AALI-C-Mgmt interface + +Frequency: N/A + +**Table 4.3.1.8-1: setAalAccelIdentifier Operation** + +| Operation | Direction | +|-----------------------|-------------------------------------| +| setAalAccelIdentifier | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.1.8-2: setAalAccelIdentifier Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| vendor_name | 1 | String | M | Input parameter that is used by the HAM to match the vendor of the HW Accelerator. | +| model | 1 | String | M | Input parameter that is used by the HAM to match the model of the HW Accelerator. | +| serial_number | 1 | String | M | Input parameter that is used by the HAM to match the serial number of the HW Accelerator. | +| hw_accel_id | 1 | Identifier | M | Unique Identification of the AAL-HW-Accel in the O-Cloud.<br><br>If the HAM has an existing hw_accel_id value mapped to the device identified by vendor_name, model and serial_number, the HAM's value will be replaced with the value provided in this parameter. | + +**Table 4.3.1.8-3: setAalAccelIdentifier Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|---------------------------------|-----------|-------------------------------------| +| status_of_operation | | <i>Reference WG6 info model</i> | M | Returns the status of the procedure | + +#### 4.3.1.9 aalHamRegistrationNotification + +Description: The HAM Registration Notification API is used by the HAM to register itself with the SMO. This occurs: + +- After the HAM is ready to support interactions with the IMS. +- After HAM is configured with the IMS and HAM's service endpoints. +- When the HAM or IMS service endpoint has been modified. + +**Table 4.3.1.9-1: aalHamRegistrationNotification Operation** + +| Operation | Direction | +|--------------------------------|-------------------------------------| +| aalHamRegistrationNotification | HW Accelerator Manager (HAM) => IMS | + +**Table 4.3.1.9-2: aalHamRegistrationNotification Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|-----------|-----------|----------------------------------------------------------------| +| aalHam_ep | 1 | String | M | The service end point for the IMS to communicate with the HAM. | + +### 4.3.2 Infrastructure Monitoring Service + +#### 4.3.2.1 Fault Service Operations + +The AALI-C-Mgmt API provides operations to query the current Fault conditions for managed resources and raise event notifications to subscribed entities when Fault conditions occur. These Fault conditions are operational conditions of the managed resource and can be retrieved from the “faults” attribute of the associated managed resource. + +The HAM provides the capability to query the current Fault conditions for the HW Accelerator and AAL-LPU(s). + +##### 4.3.2.1.1 getAalHwAccelFaults + +Description: This API is used between the IMS and HAM to query the currently active faults of the HW Accelerator. + +Pre-conditions: HW Accelerator Device is initialized, and HAM is operational. + +Triggers: On demand request via AALI-C-Mgmt interface + +Frequency: Infrequent + +**Table 4.3.2.1.1-1: getAalHwAccelFaults Operation** + +| Operation | Direction | +|---------------------|-------------------------------------| +| getAalHwAccelFaults | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.2.1.1-2: getAalHwAccelFaults Input Parameter** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|------------------------------------| +| hw_accel_id | | Identifier | M | This ID is unique within a O-Cloud | + +**Table 4.3.2.1.1-3: getAalHwAccelFaults Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|---------------------------------|-----------|------------------------------------------------| +| status_of_operation | | <i>Reference WG6 info model</i> | | Returns the status of the operation | +| faults | 0.. N | Structure | M | The currently active Fault list | +| > hw_accel_id | 1 | Identifier | M | This ID is unique within an O-Cloud | +| > detected_time | 1 | DateTime | M | The time the Fault condition was last detected | +| > fault_id | 1 | Identifier | M | The Fault identifier. | + +##### 4.3.2.1.2 getAalLpuFaults + +Description: This API is used between the IMS and HAM to query the currently active faults of the AAL-LPUs (per AAL-LPU). + +Pre-conditions: HW Accelerator Device is initialized, and HAM is operational. + +Triggers: On demand request via AALI-C-Mgmt interface + +Frequency: Infrequent + +**Table 4.3.2.1.2-1: getAalHwAccelFaults Operation** + +| Operation | Direction | +|-----------------|-------------------------------------| +| getAalLpuFaults | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.2.1.2-2: getAalHwAccelFaults Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|-------------------------------------------| +| hw_accel_id | 1.. N | Identifier | M | This ID is unique within an O-Cloud | +| aal_lpu_handle | | Identifier | M | This ID is unique within a HW Accelerator | + +**Table 4.3.2.1.2-3: getAalHwAccelFaults Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|--------------------------------------------|-----------|----------------------------------------------------------------------------| +| status_of_operation | | <i>Reference<br/>WG10 object<br/>model</i> | M | Returns the status of the operation | +| faults | 0.. N | Structure | M | The currently active Fault conditions list | +| > hw_accel_id | 1 | Identifier | M | This ID is unique within an O-Cloud | +| > aal_lpu_handle | 1 | Identifier | M | This ID is unique within a HW Accelerator needed for LPU Fault conditions. | +| > detected_time | 1 | DateTime | M | The time the Fault condition was last detected | +| > fault_id | 1 | Identifier | M | The Fault identifier. | + +#### 4.3.2.2 Fault Notifications + +The HW Accelerator Manager (HAM) provides the capability to subscribe to receive Fault conditions for the HW Accelerator and AAL-LPU(s) that it is managing. This capability is managed within the O-Cloud through the subscription\_id identifier. + +##### 4.3.2.2.1 Subscription\_id + +The subscription\_id is an identifier used to describe the fault notification relationship between the IMS and a given HAM; it applies indirectly to the notification of faults from all the HW Accelerators that the HAM is managing. + +The subscription\_id includes a list of all the faults that the IMS needs to be notified in the event of their occurrence in any one of the HW Accelerators that is being managed by the HAM. + +The validity and duration of the subscription\_id shall be defined by the following: + +- The existence and validity of the IMS to HAM relationship. For example, if the HAM needs to be updated or modified then a new subscription\_id needs to be issued by the IMS. +- The existence and validity of any of the HW Accelerators for which the HAM is responsible for and is managing for the IMS. If any one of these HW Accelerators requires an update, upgrade, or any other modification is performed then the subscription\_id between the IMS and the given HAM needs to be renewed. + +Any notification that the HAM issues to the IMS pertaining to a modification in the state or operation of the HW Accelerator by the HAM shall result in an update/renewal of the subscription\_id with the IMS. + +- In the case of restart or power-cycles in the HW Accelerator managed by the HAM the subscription\_id doesn't have to be renewed since restart or power-cycle does not alter the faults supported by the HW Accelerator or the fault formats. + +If the IMS receives a fault notification from a HAM that includes a subscription\_id that does not match a subscription\_id maintained by the IMS for that given HAM, the IMS shall then delete that subscription by calling the deleteAalFaultSubscription API with the subscription\_id followed by calling the createAalFaultSubscription API with new subscription\_id(s) to (re-)create a new fault subscription. + +##### 4.3.2.2.2 createAalFaultSubscription + +Description: This API is used between the IMS and HAM to create fault subscriptions for AAL-LPUs and the HW Accelerator managed resources. + +Pre-conditions: HW Accelerator Device is initialized, and HAM is operational. + +Triggers: On demand request via AALI-C-Mgmt interface. + +Frequency: Infrequent + +**Table 4.3.2.2.2-1: createAalFaultSubscription Operation** + +| Operation | Direction | +|----------------------------|-------------------------------------| +| createAalFaultSubscription | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.2.2.2-2: createAalFaultSubscription Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-------------------|-------------|------------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| subscriptions | 1.. N | Structure | M | The subscriptions to be created. | +| > subscription_id | 1 | Identifier | M | Unique identification of the subscription in the O-Cloud. | +| > filter_criteria | 1 | String | M | <p>Policy to subscribe that is evaluated by the HAM to determine what faults for which AAL managed resource types and instances should be notified to the IMS.</p> <p>Each criteria includes the Fault condition(s) for a managed resource type. The criteria accepts Fault condition/ managed resource types that are associated with a set of instances of that type of resource.</p> <p>Multiple criteria can be part of the subscription with criteria evaluation operators (i.e., and, or) that can be used to evaluate the individual criterion.</p> <p>For example:</p> <p>To subscribe to temperature faults for all HW Accelerator resources and the memory exhausted fault for an AAL-LPU with an identifier of 45; the subscription looks like:</p> <p>((TemperatureFault HW-Accel *) and (MemoryExhausted AAL-LPU 45))</p> | + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|-----------|-----------|---------------------------------------------------------------------------------------------------------------------------| +| | | | | NOTE: The filter_criteria element is further described as part of the protocol specific implementation of this operation. | + +**Table 4.3.2.2.2-3: createAalFaultSubscription Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------|-------------|-----------------------------------------|-----------|---------------------------------------------| +| subscriptions | 1.. N | Structure | M | Status of the subscriptions. | +| > subscription_id | 1 | Identifier | M | Returns the identifier of the subscription. | +| > status_of_operation | 1 | <i>Reference<br/>WG6 info<br/>model</i> | M | Returns the status of the operation. | + +##### 4.3.2.2.3 getAalFaultSubscription + +Description: This API is used between the IMS and HAM to query Fault Subscriptions for the HW Accelerator. + +Pre-conditions: HW Accelerator Device is initialized, and HAM is operational. + +Triggers: On demand request via AALI-C-Mgmt interface + +Frequency: Infrequent + +**Table 4.3.2.2.3-1: getAalFaultSubscription Operation** + +| Operation | Direction | +|-------------------------|-------------------------------------| +| getAalFaultSubscription | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.2.2.3-2: getAalFaultSubscription Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|----------------------------------------------------------------------------------------------------------------------| +| subscription_id | 1.. N | Identifier | O | List of identifiers to retrieve.<br><br>If this attribute is not present, all subscriptions in the HAM are returned. | + +**Table 4.3.2.2.3-3: getAalFaultSubscription Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|-------------------|-------------|------------|-----------|------------------------------------------------------------------------------------------------------------------------------------------| +| subscriptions | 0.. N | Structure | M | Returns the subscriptions | +| > subscription_id | 1 | Identifier | M | Returns the identifiers of the requested subscriptions. | +| > filter_criteria | 1 | String | M | Criteria evaluated by the HAM to determine what faults for which AAL managed resource types and instances should be notified to the IMS. | + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------|-------------|--------------------------------|-----------|-----------------------------------------------------------------------| +| > status_of_operation | 1 | Reference<br>WG6 info<br>model | | Returns the status of the operation for each subscription identifier. | + +##### 4.3.2.2.4 deleteAalFaultSubscription + +Description: The HAM provides the ability for the IMS to delete a subscription for notification of faults. + +Pre-conditions: HW Accelerator Device is initialized, and HAM is operational. + +Triggers: On demand request via AALI-C-Mgmt interface. + +Frequency: Infrequent + +**Table 4.3.2.2.4-1: deleteAalFaultSubscription Operation** + +| Operation | Direction | +|----------------------------|-------------------------------------| +| deleteAalFaultSubscription | IMS => HW Accelerator Manager (HAM) | + +**Table 4.3.2.2.4-2: deleteAalFaultSubscription Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|------------|-----------|-------------------------------| +| subscription_id | 1.. N | Identifier | M | List of identifiers to delete | + +**Table 4.3.2.2.4-3: deleteAalFaultSubscription Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------|-------------|--------------------------------|-----------|-----------------------------------------------------------------------| +| subscriptions | 1.. N | Structure | M | Returns the subscriptions that were deleted. | +| > subscription_id | 1 | Identifier | M | Returns the identifiers of the subscriptions that were deleted. | +| > status_of_operation | 1 | Reference<br>WG6 info<br>model | | Returns the status of the operation for each subscription identifier. | + +##### 4.3.2.2.5 aalFaultNotification + +Description: The HW Accelerator Manager emits notifications to the IMS based on a subscription. + +Pre-conditions: HW Accelerator Device is initialized, and HAM is operational. + +Triggers: On demand request via AALI-C-Mgmt interface. + +Frequency: Infrequent + +**Table 4.3.2.2.5-1: aalFaultNotification Operation** + +| Operation | Direction | +|----------------------|-------------------------------------| +| aalFaultNotification | HW Accelerator Manager (HAM) => IMS | + +| Parameter | Cardinality | Data Type | Qualifier | Description | +|------------------|-------------|-------------|-----------|------------------------------------------------------------------| +| subscription_id | 1 | Identifier | M | Identifier of the subscription. | +| faults | 0.. N | Structure | M | The current fault list. | +| > hw_accel_id | 1 | Identifier | M | This ID is unique within an O-Cloud. | +| > aal_lpu_handle | 1 | Identifier | O | This ID is unique within a HW Accelerator needed for LPU faults. | +| > detected_time | 1 | DateTime | M | The time the fault condition was last detected. | +| > event | 1 | Enumeration | M | The event that caused the notification.<br>Values: Raise, Clear | +| > fault_id | 1 | Identifier | M | The identifier of the fault condition. | + +# Chapter 5 AALI-C-APP + +## 5.1 AALI-C-App Identification & Representation + +Within the AAL Application's process address space each, AAL-LPU can be represented by a generalized object handle (i.e., aal\_lpu\_handle) provided by the AAL implementation in order for the AAL Application to use the capabilities of the AAL-LPU. + +Before the AALI-C-App interface can be used, the AAL implementation must be initialized by the AAL Application. The initialization of the AAL implementation allows for initialization, setup and discovery routines that are specific to an implementation. Where needed, the initialization of the AAL implementation also allows the AAL Application to inform the AAL implementation what O-Cloud Resources and associated attributes that the DMS has assigned to and can be used by the AAL Application. As an example, the DMS may inform the AAL Application about the AAL Application's assigned O-Cloud Resource using environment variables that identify the O-Cloud Resource and associated attributes within the POD/container/VM. The identification of these O-Cloud Resources are to be shared with the AAL implementation by the AAL Application through the AALI-C-App initialization operation. + +Depending on the HW design and implementation choice, an AAL-LPU implementation may want to accelerate multiple AAL Profiles, offer support for sharing HW Accelerator resources between multiple threads and/or partition AAL-LPU resources between multiple cells. For this reason, the AAL-Profile-Instance and AAL Profile Queue logical managed resources can optionally be used by the AAL Application to + +- distinguish between multiple supported AAL profiles per AAL-LPU +- prioritize access to AAL-LPU resources. +- group operation requests +- partition AAL-LPU resources +- allow parallel access through the AAL Application interface for multiple threads / cores. + +As a logical managed resources, an AAL Profile Queue does not reflect a HW design specification or requirement but an AAL interface specification. + +The AALI-C-App configuration is done on a per AAL-LPU basis. That is, for each AAL-LPU that is assigned to the AAL Application, the AAL Implementation exposes the AALI-C-App to the AAL Application to initialize and configure each AAL-Profile-Instance and AAL-Profile-Queue. + +## 5.2 AALI-C-App operations and events + +The below table lists the operations and events as part of the AALI-C-App interface. + +**Table 5.2-1: AALI-C-App operations and events** + +| Category | Operations/<br>Events | Objects | +|--------------------------------|-----------------------------|----------------------| +| <b>Initialization Services</b> | initAal | N/A | +| | cleanupAal | N/A | +| <b>Inventory Services</b> | getAalLpuInfo | AAL-LPU | +| <b>Configuration Services</b> | createAalProfileInstance | AAL-LPU | +| | getAalProfileInstanceConfig | AAL-Profile-Instance | +| | setAalProfileInstanceConfig | AAL-Profile-Instance | +| | deleteAalProfileInstance | AAL-Profile-Instance | +| | setAalProfileQueueConfig | AAL-Profile-Queue | +| | getAalProfileQueueConfig | AAL-Profile-Queue | +| <b>Operations</b> | startAalProfileInstance | AAL-Profile-Instance | +| | stopAalProfileInstance | AAL-Profile-Instance | +| | startAalProfileQueue | AAL-Profile-Queue | +| | stopAalProfileQueue | AAL-Profile-Queue | +| <b>Transport Operations</b> | createBufferPool | N/A | +| | allocBuffer | N/A | +| | getBufferAddr | N/A | +| | getBufferSize | N/A | +| | sendBuffer | N/A | +| | receiveBuffer | N/A | +| | freeBuffer | N/A | +| | destroyBufferPool | N/A | + +*Editor's note: Use of AAL-Profile-Queue operations for user plane data transfer and buffer API operations needs to be clarified.* + +## 5.3 AALI-C-App Operations and Events Sequence and State Diagram + +### 5.3.1 AALI-C-App State + +The below state diagram shows the high-level state and state transitions for all AALI-C-App Operations and Events + +``` +@startuml +skinparam StateBackgroundColor #FEFECF +skinparam StateBorderColor #A80036 +skinparam ArrowColor #A80036 +skinparam ArrowHeadColor #A80036 + +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +hide members +hide empty description + +[*] --> AAL : initAal + +state AAL { + [*] --> AalInitialized + AalInitialized --> AalInitialized : getAalLpuInfo + AalInitialized -left-> [*] : cleanupAal + AalInitialized --> AalProfileInstance + + state AalProfileInstance { + [*] --> Stopped : createAalProfileInstance (s) + Stopped --> Started : startAalProfileInstance + Started --> Stopped : stopAalProfileInstance + Stopped --> Stopped : setAalProfileInstanceConfig\ngetAalProfileInstanceConfig + Started --> Started : getAalProfileInstanceConfig + Stopped --> [*] : deleteAalProfileInstance + Started --> AalProfileQueue + + state AalProfileQueue { + [*] --> QueueStopped + QueueStopped --> QueueStarted : startAalProfileQueue + QueueStarted --> QueueStopped : stopAalProfileQueue + QueueStopped --> QueueStopped : setAalProfileQueueConfig\ngetAalProfileQueueConfig + QueueStarted --> QueueStarted : getAalProfileQueueConfig\nPerform Operations + } + } +} + +@enduml +``` + +![UML State Machine Diagram for AAL (Access Abstraction Layer) showing the flow between AAL, AalProfileInstance, and AalProfileQueue components.](63547b8aeefc842f9414426810b13a2c_img.jpg) + +``` + +stateDiagram-v2 + [*] --> AAL : initAal + state AAL { + [*] --> AalInitialized + AalInitialized --> [*] : cleanupAal + AalInitialized --> AalInitialized : getAalLpinfo + AAL --> AalProfileInstance + state AalProfileInstance { + [*] --> Stopped + Stopped --> [*] : createAalProfileInstance (s) + Stopped --> Stopped : setAalProfileInstanceConfig + Stopped --> Stopped : getAalProfileInstanceConfig + Stopped --> Started : startAalProfileInstance + Stopped --> [*] : deleteAalProfileInstance + Started --> Stopped : stopAalProfileInstance + Started --> Started : getAalProfileInstanceConfig + AalProfileInstance --> AalProfileQueue + state AalProfileQueue { + [*] --> QueueStopped + QueueStopped --> [*] : setAalProfileQueueConfig + QueueStopped --> QueueStopped : getAalProfileQueueConfig + QueueStopped --> QueueStarted : startAalProfileQueue + QueueStarted --> QueueStopped : stopAalProfileQueue + QueueStarted --> QueueStarted : getAalProfileQueueConfig + QueueStarted --> QueueStarted : Perform Operations + } + } + } + +``` + +The diagram illustrates the state transitions for the AAL (Access Abstraction Layer) component, which is composed of three sub-components: AAL, AalProfileInstance, and AalProfileQueue. + +- AAL Component:** + - Starts at an initial state and transitions to the **AalInitialized** state upon receiving the **initAal** message. + - The **AalInitialized** state has a self-loop for **getAalLpinfo** and a transition to a final state upon receiving **cleanupAal**. + - The AAL component transitions to the **AalProfileInstance** component. +- AalProfileInstance Component:** + - Starts at an initial state and transitions to the **Stopped** state upon receiving the **createAalProfileInstance (s)** message. + - The **Stopped** state has self-loops for **setAalProfileInstanceConfig** and **getAalProfileInstanceConfig**. + - Transitions from **Stopped** include **startAalProfileInstance** to the **Started** state and **deleteAalProfileInstance** to a final state. + - The **Started** state has a self-loop for **getAalProfileInstanceConfig** and a transition back to **Stopped** upon receiving **stopAalProfileInstance**. + - The AalProfileInstance component transitions to the **AalProfileQueue** component. +- AalProfileQueue Component:** + - Starts at an initial state and transitions to the **QueueStopped** state. + - The **QueueStopped** state has self-loops for **setAalProfileQueueConfig** and **getAalProfileQueueConfig**. + - Transitions from **QueueStopped** include **startAalProfileQueue** to the **QueueStarted** state and **stopAalProfileQueue** back to **QueueStopped**. + - The **QueueStarted** state has a self-loop for **getAalProfileQueueConfig** and a self-loop for **Perform Operations**. + +UML State Machine Diagram for AAL (Access Abstraction Layer) showing the flow between AAL, AalProfileInstance, and AalProfileQueue components. + +### 5.3.2 AALI-C-App API Init Sequence + +The below sequence diagram shows the high-level initialization and configuration procedure for the AALI-C-App. + +``` + +@startuml +Autonumber +Skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +Box "O-RAN" #NavajoWhite + Participant "O-DU" as ODU << OAAL-App>> +end box +Box "Cloud Platform" #lightseagreen + participant "AAL Implementation" as AAL +End box + +note over ODU, AAL +Assumed the O-DU is already instantiated on the O-Cloud +With desired HW Accelerator resources assigned from O2 and +Configuration through O1 interface is complete +endnote +==Initialization Services== +ODU -> AAL : initAal +AAL --> ODU : return + +==Inventory Services== +ODU -> AAL : getAalLpuInfo +AAL --> ODU : Response getAalLpuInfo +==Configuration & Operation Services== +loop for each AAL-LPU +loop for each AAL-Profile-Instance +ODU -> AAL : createAalProfileInstance +AAL --> ODU : AAL-Profile-Instance handle / identifier +ODU -> AAL : setAalProfileInstanceConfig +AAL --> ODU : return +ODU -> AAL : startAalProfileInstance +AAL --> ODU : return +loop for each AAL-Profile-Queue +ODU -> AAL : setAalProfileQueueConfig +AAL --> ODU : return +ODU -> AAL : startAalProfileQueue +AAL --> ODU : return +end loop +end loop +end loop +ODU -> AAL : cleanupAal +AAL --> ODU : return + +@enduml + +``` + +![Sequence diagram showing the interaction between O-RAN and Cloud Platform for AAL services. The diagram is divided into three sections: Initialization Services, Inventory Services, and Configuration & Operation Services. The O-RAN side contains the « OAAL-App » O-DU, and the Cloud Platform side contains the AAL Implementation. A note at the top states: 'Assumed the O-DU is already instantiated on the O-Cloud With desired HW Accelerator resources assigned from O2 and Configuration through O1 interface is complete'. The Initialization Services section shows a call to '1 initAal' and a return. The Inventory Services section shows a call to '3 getAalLpuInfo' and a return '4 Response getAalLpuInfo'. The Configuration & Operation Services section contains three nested loops: an outer loop 'loop [for each AAL-LPU]', an inner loop 'loop [for each AAL-Profile-Instance]', and a third loop 'loop [for each AAL-Profile-Queue]'. The inner loop contains calls '5 createAalProfileInstance', '7 setAalProfileInstanceConfig', and '9 startAalProfileInstance', with returns '6 AAL-Profile-Instance handle / identifier' and '8 return'. The third loop contains calls '11 setAalProfileQueueConfig' and '13 startAalProfileQueue', with returns '12 return' and '14 return'. After the loops, there is a call '15 cleanupAal' and a return '16 return'.](8fc34bc59ac1849b848a737b2cd379e5_img.jpg) + +**O-RAN** + +« OAAL-App » +O-DU + +**Cloud Platform** + +AAL Implementation + +Assumed the O-DU is already instantiated on the O-Cloud +With desired HW Accelerator resources assigned from O2 and +Configuration through O1 interface is complete + +**Initialization Services** + +1 initAal + +2 return + +**Inventory Services** + +3 getAalLpuInfo + +4 Response getAalLpuInfo + +**Configuration & Operation Services** + +**loop** [for each AAL-LPU] + +**loop** [for each AAL-Profile-Instance] + +5 createAalProfileInstance + +6 AAL-Profile-Instance handle / identifier + +7 setAalProfileInstanceConfig + +8 return + +9 startAalProfileInstance + +10 return + +**loop** [for each AAL-Profile-Queue] + +11 setAalProfileQueueConfig + +12 return + +13 startAalProfileQueue + +14 return + +15 cleanupAal + +16 return + +« OAAL-App » +O-DU + +AAL Implementation + +Sequence diagram showing the interaction between O-RAN and Cloud Platform for AAL services. The diagram is divided into three sections: Initialization Services, Inventory Services, and Configuration & Operation Services. The O-RAN side contains the « OAAL-App » O-DU, and the Cloud Platform side contains the AAL Implementation. A note at the top states: 'Assumed the O-DU is already instantiated on the O-Cloud With desired HW Accelerator resources assigned from O2 and Configuration through O1 interface is complete'. The Initialization Services section shows a call to '1 initAal' and a return. The Inventory Services section shows a call to '3 getAalLpuInfo' and a return '4 Response getAalLpuInfo'. The Configuration & Operation Services section contains three nested loops: an outer loop 'loop [for each AAL-LPU]', an inner loop 'loop [for each AAL-Profile-Instance]', and a third loop 'loop [for each AAL-Profile-Queue]'. The inner loop contains calls '5 createAalProfileInstance', '7 setAalProfileInstanceConfig', and '9 startAalProfileInstance', with returns '6 AAL-Profile-Instance handle / identifier' and '8 return'. The third loop contains calls '11 setAalProfileQueueConfig' and '13 startAalProfileQueue', with returns '12 return' and '14 return'. After the loops, there is a call '15 cleanupAal' and a return '16 return'. + +### 5.3.3 AALI-C-Transport API Sequence + +The AALI-C-App Transport API sequence is divided into two sets of call flows in the following subsections: + +- Sec. 5.3.3.1 focusses on call flows related to allocation of buffers(s) to be used with other AALI-C-App Transport APIs. +- Sec. 5.3.3.2 and its subsections focus on call flows detailing the various procedures for sending and receiving buffer(s) using AALI-C-App Transport API. + +#### 5.3.3.1 Allocation of AAL Buffer(s) + +The AALI-C-App Transport API supports allocation of buffers from either pre-created buffer pool(s) or from memory not mapped to pre-created buffer pool(s). Send buffer(s) are allocated by the AAL Application, while Receive buffer(s) are allocated either by the AAL Application or by the AAL Implementation. + +NOTE 2: The terms "AAL" and "AAL Implementation" are used interchangeably in the tables below. + +**Table 5.3.3.1-1 : Allocation of AAL Buffer(s) workflow steps** + +| | Evolution / Specification | <<Uses>><br>Related use | +|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | The AAL Application (e.g., O-DU) creates and allocates memory to be used when offloading operations to the AAL Implementation. | | +| Actors and Roles | AAL Application: calls buffer operations with desired input parameters.<br>AAL: executes buffer operations. | | +| Assumptions | This sequence is representative of how the AAL Application uses the buffer operations. | | +| Pre-conditions | AAL Implementation is initialized. | | +| Begins when | The AAL Application is ready to create buffers. | | +| Steps 1-2 (O) | The AAL Application can optionally create a buffer pool by calling the createBufferPool operation. On success, the AAL returns a buffer_pool_handle to the created buffer pool. | | +| Steps 3-4 (M) | The AAL Application allocates a buffer to use in future AAL operations. The buffer can be allocated from a pre-created buffer pool from steps 1 and 2, or can be dynamically allocated. On success, the AAL returns a buffer_handle. | | +| Steps 5 – 8 (O) | The AAL Application can retrieve the pointer to the buffer to add/modify/delete the content of the buffers. The AAL Application can also check the size of the buffer. | | +| Steps 9 – 10 (M) | Once the AAL Application is finished with the buffer it can free the buffer by calling the bufferFree operation. | | +| Steps 11 – 12 (O) | If previously created in steps 1 and 2 and the AAL Application is finished with the buffer pool, the AAL Application will destroy the buffer pool. | | + +| | | | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------|--| +| Ends when | All memory is freed and returned to the AAL Implementation. | | +| Exceptions | Exceptions can occur in steps 1, 3, 5, 7, 9 and 10 if the AAL fails to allocate or free memory. The AAL will report an error. | | +| Post Conditions | Memory is freed, AAL Application is free to continue processing. | | +| Traceability | To be added later. | | + +##### 5.3.3.1.1 Sequence Diagram + +``` + +@startuml +Autonumber +Skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +Box "O-RAN" #NavajoWhite + Participant "O-DU" as ODU << AAL-App>> +end box +Box "Cloud Platform" #lightseagreen + participant "AAL Implementation" as AAL +End box + +activate ODU +ref over ODU, AAL +AALI-C-App Sequence assumptions (Sec. 5.3.2) +End ref + +==Inventory Services== +ref over ODU, AAL +AALI-C-App API Sequence call flow related to Inventory Service (Sec. 5.3.2) +End ref + +==Creating Buffer Pools and Allocating Buffers == + +opt if buffer pool creation +ODU -> AAL : createBufferPool +activate AAL +AAL --> ODU : return buffer pool handle(s) +Deactivate AAL +End opt + +Note over ODU, AAL +Allocate a buffer using pre-created buffer pool with buffer_pool_handle +or allocate dynamically with NULL buffer_pool_handle parameter +Endnote +ODU -> AAL : allocBuffer +activate AAL +AAL --> ODU : return buffer handle +deactivate AAL + +autoactivate on +opt Get buffer address and buffer size using buffer handle if needed +ODU -> AAL : getBufferAddr +AAL --> ODU: return buffer address +ODU -> AAL: getBufferSize +AAL --> ODU: return buffer size +End opt + +ref over ODU, AAL +AALI-C-App API Sequence call flow related to AAL-LPU, AAL-Profile-Instance + +``` + +``` +and AAL-Profile-Queue initialization & configuration (Sec. 5.3.2) +end ref + +==Run Time Operations == +ref over ODU, AAL +AALI-C-App API Sequence call flow related to Sending/Receiving Buffer(s) (Sec. 5.3.3.2) +End ref + +==Free Buffer, Destroy Buffer Pool Operations == + +ODU -> AAL : freeBuffer +AAL --> ODU : success/failure + +opt if buffer pool was created by the AAL Application +ODU -> AAL : destroyBufferPool +AAL --> ODU : success/failure +End opt + +deactivate ODU +@enduml +``` + +![Sequence diagram showing the interaction between O-RAN and Cloud Platform for AAL-App O-DU and AAL Implementation. The diagram includes sections for Inventory Services, Creating Buffer Pools and Allocating Buffers, Run Time Operations, and Free Buffer, Destroy Buffer Pool Operations.](afb680ec82911ef602424f411ad6c47c_img.jpg) + +**O-RAN** + +«AAL-App» +O-DU + +**Cloud Platform** + +AAL Implementation + +ref +AALI-C-App Sequence assumptions (Sec. 5.3.2) + +**Inventory Services** + +ref +AALI-C-App API Sequence call flow related to Inventory Service (Sec. 5.3.2) + +**Creating Buffer Pools and Allocating Buffers** + +opt **[if buffer pool creation]** +1 createBufferPool +2 return buffer pool handle(s) + +Allocate a buffer using pre-created buffer pool with buffer\_pool\_handle or allocate dynamically with NULL buffer\_pool\_handle parameter + +3 allocBuffer +4 return buffer handle + +opt **[Get buffer address and buffer size using buffer handle if needed]** +5 getBufferAddr +6 return buffer address +7 getBufferSize +8 return buffer size + +ref +AALI-C-App API Sequence call flow related to AAL-LPU, AAL-Profile-Instance and AAL-Profile-Queue initialization & configuration (Sec. 5.3.2) + +**Run Time Operations** + +ref +AALI-C-App API Sequence call flow related to Sending/Receiving Buffer(s) (Sec. 5.3.3.2) + +**Free Buffer, Destroy Buffer Pool Operations** + +9 freeBuffer +10 success/failure + +opt **[if buffer pool was created by the AAL Application]** +11 destroyBufferPool +12 success/failure + +«AAL-App» +O-DU + +AAL Implementation + +Sequence diagram showing the interaction between O-RAN and Cloud Platform for AAL-App O-DU and AAL Implementation. The diagram includes sections for Inventory Services, Creating Buffer Pools and Allocating Buffers, Run Time Operations, and Free Buffer, Destroy Buffer Pool Operations. + +#### 5.3.3.2 Procedure for Buffer(s) Send and Receive + +The AALI-C-App Transport API supports the following high level use cases + +- Send Buffer Synchronous Mode with buffer free +- Send Buffer Synchronous Mode without buffer free +- Send Buffer Asynchronous Mode with buffer free +- Send Buffer Asynchronous Mode without buffer free +- Receive Buffer Synchronous Mode with non-NULL buffer\_handles(s) input +- Receive Buffer Synchronous Mode with NULL buffer\_handles(s) input +- Receive Buffer Asynchronous Mode with non-NULL buffer\_handle(s) input +- Receive Buffer Asynchronous Mode with NULL buffer\_handle(s) input + +In the use cases above, 'with buffer free' and 'without buffer free' imply that the input parameter 'buffer\_free' = 'TRUE' (or 1) and 'FALSE' (or 0) respectively in sendBuffer operation (Sec. 5.4.3.5). + +These use cases are detailed in the sections below. + +##### 5.3.3.2.1 Send Buffer Synchronous Mode with buffer free + +**Table 5.3.3.2.1-1 : Send Buffer Synchronous Mode with buffer free workflow steps** + +| | Evolution / Specification | <<Uses>><br>Related use | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | The AAL Application (e.g., O-DU) sends buffer(s) to the AAL for processing in synchronous mode with buffer free. | | +| Actors and Roles | AAL Application: formats buffer and its content, and calls AAL to send the buffer.<br><br>AAL Implementation executes sendBuffer operation. | | +| Assumptions | This sequence is representative of how the AAL Application uses the sendBuffer operation in a synchronous manner with buffer free enabled. | | +| Pre-conditions | At least one AAL-Profile-Instance is configured and started. At least one AAL-Profile-Queue is configured and started. Buffer(s) to be sent are allocated. | | +| Begins when | The AAL Application is ready to send buffer. | | +| Step 1 (M) | The AAL Application calls the sendBuffer API to transfer the buffer to the AAL which will execute the sendBuffer operation. The AAL Application thread invoking the API is blocked waiting for the sendBuffer operation to complete. | | +| Steps 2 - 3 (M) | The AAL internally frees the buffer back to the buffer pool upon completion of the sendBuffer operation.<br><br>Once done, the AAL returns the status of the operation back to the AAL Application and unblock the AAL Application call thread process. | | +| Ends when | sendBuffer operation has completed. | | +| Exceptions | Exceptions can occur if the sendBuffer operation fails. Status indicating failure will be returned in Step 3. | | + +| | | | +|-----------------|----------------------------------------------|--| +| Post Conditions | The AAL Application can continue processing. | | +| Traceability | To Be added later. | | + +``` + +@startuml +Autonumber +Skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +autoactivate on + +Box "O-RAN" #NavajoWhite + Participant "O-DU" as ODU << AAL-App>> +end box +Box "Cloud Platform" #lightseagreen + participant "AAL Implementation" as AAL +End box + +activate ODU + +ref over ODU, AAL +Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers +end ref + +==Synchronous Send Buffer (with buffer free) == + +ODU -> AAL : sendBuffer +Deactivate ODU + +note over AAL +Perform operations and send all buffers. +Return when all buffers are sent. +endnote + +AAL -> AAL : free buffer + +AAL --> ODU : return status +Activate ODU + +deactivate ODU +@enduml + +``` + +![Sequence diagram showing the interaction between O-RAN and Cloud Platform for Synchronous Send Buffer (with buffer free) mode. The O-RAN side has a «AAL-App» O-DU. The Cloud Platform side has an AAL Implementation. The sequence starts with a reference to Section 5.3.3.1. Step 1: «AAL-App» O-DU calls sendBuffer on AAL Implementation. Step 2: AAL Implementation performs operations and sends all buffers, then returns. Step 3: «AAL-App» O-DU receives the return status.](469425e9d76750c8b4788066064a5492_img.jpg) + +``` + +sequenceDiagram + participant O-RAN as O-RAN + participant CP as Cloud Platform + participant AALApp as «AAL-App» O-DU + participant AALImpl as AAL Implementation + + O-RAN-->>CP: ref Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers + Note over CP: Synchronous Send Buffer (with buffer free) + AALApp->>AALImpl: 1 sendBuffer + activate AALImpl + Note right of AALImpl: Perform operations and send all buffers. Return when all buffers are sent. + AALImpl-->>AALApp: 2 free buffer + deactivate AALImpl + AALApp-->>AALApp: 3 return status + +``` + +Sequence diagram showing the interaction between O-RAN and Cloud Platform for Synchronous Send Buffer (with buffer free) mode. The O-RAN side has a «AAL-App» O-DU. The Cloud Platform side has an AAL Implementation. The sequence starts with a reference to Section 5.3.3.1. Step 1: «AAL-App» O-DU calls sendBuffer on AAL Implementation. Step 2: AAL Implementation performs operations and sends all buffers, then returns. Step 3: «AAL-App» O-DU receives the return status. + +##### 5.3.3.2.2 Send Buffer Synchronous Mode without buffer free + +**Table 5.3.3.2.2-1 : Send Buffer Synchronous Mode without buffer free workflow steps** + +| | Evolution / Specification | <<Uses>><br>Related use | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | The AAL Application sends buffer(s) to the AAL for processing in synchronous mode without buffer free. | | +| Actors and Roles | AAL Application: formats buffer and its content, and calls AAL to send the buffer.<br><br>AAL Implementation: executes sendBuffer operation. | | +| Assumptions | This sequence is representative of how the AAL Application uses the sendBuffer operation in a synchronous manner without buffer free enabled. | | +| Pre-conditions | At least one AAL-Profile-Instance is configured and started. At least one AAL-Profile-Queue is configured and started. Buffer(s) to be sent are allocated. | | +| Begins when | The AAL Application is ready to send buffer. | | +| Steps 1 – 2 (M) | The AAL Application calls the sendBuffer API to transfer the buffer to the AAL which will execute the sendBuffer operation. The AAL Application thread invoking the API is blocked waiting for the sendBuffer operation to complete. | | + +| | | | +|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| | The AAL processes the operation and sends the buffers. Once done, the AAL returns the status of the operation back to the AAL Application and unblock the AAL Application call thread process. | | +| Step 3 (M) | The AAL Application, when finished with the buffer, calls freeBuffer operation and the AAL will free the buffer back to the buffer pool. | | +| Ends when | sendBuffer operation has completed. | | +| Exceptions | Exceptions can occur if the sendBuffer operation fails. Status indicating failure will be returned in Step 2. | | +| Post Conditions | The AAL Application can continue processing. | | +| Traceability | To Be added later. | | + +``` + +@startuml +Autonumber +Skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +autoactivate on + +Box "O-RAN" #NavajoWhite + Participant "O-DU" as ODU << AAL-App>> +end box +Box "Cloud Platform" #lightseagreen + participant "AAL Implementation" as AAL +End box + +activate ODU + +ref over ODU, AAL +Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers +end ref + +==Synchronous Send Buffer (without buffer free) == + +ODU -> AAL : sendBuffer +deactivate ODU + +note over AAL +Perform operations and send all buffers. +Return when all buffers are sent. +Endnote + +AAL --> ODU : return status +activate ODU +ODU -> AAL: freeBuffer +AAL --> ODU : success/failure + +deactivate ODU +@enduml + +``` + +![Sequence diagram for Synchronous Send Buffer (without buffer free) showing interactions between O-RAN and Cloud Platform.](1029e6c09fa96e2e419912415d9ff243_img.jpg) + +``` + +sequenceDiagram + participant O-RAN as O-RAN + participant Cloud Platform as Cloud Platform + participant AAL_App_O-DU as « AAL-App » O-DU + participant AAL_Implementation as AAL Implementation + + O-RAN->>Cloud Platform: 1 sendBuffer + activate AAL_Implementation + Note over AAL_Implementation: Perform operations and send all buffers. +Return when all buffers are sent. + AAL_Implementation-->>O-RAN: 2 return status + deactivate AAL_Implementation + O-RAN->>Cloud Platform: 3 freeBuffer + activate AAL_Implementation + AAL_Implementation-->>O-RAN: 4 success/failure + deactivate AAL_Implementation + +``` + +The diagram illustrates the workflow for sending a buffer synchronously without a buffer free operation. It shows two main components: O-RAN (orange) and Cloud Platform (teal). Within O-RAN, there is a component « AAL-App » O-DU. Within the Cloud Platform, there is a component AAL Implementation. The process starts with the O-RAN component sending a message '1 sendBuffer' to the AAL Implementation. The AAL Implementation then performs operations and sends all buffers, returning when all buffers are sent. This is followed by the AAL Implementation returning a status '2 return status' to the O-RAN component. The O-RAN component then sends a message '3 freeBuffer' to the AAL Implementation, which returns a success/failure status '4 success/failure' to the O-RAN component. A reference 'ref' points to 'Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers'. + +Sequence diagram for Synchronous Send Buffer (without buffer free) showing interactions between O-RAN and Cloud Platform. + +##### 5.3.3.2.3 Send Buffer Asynchronous Mode with buffer free + +**Table 5.3.3.2.3-1 : Send Buffer Synchronous Mode without buffer free workflow steps** + +| | Evolution / Specification | <<Uses>><br>Related use | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | The AAL Application sends buffer(s) to the AAL for processing in asynchronous mode with buffer free. | | +| Actors and Roles | AAL Application: formats buffer and its content, and calls AAL to send the buffer.<br><br>AAL Implementation: executes sendBuffer operation. | | +| Assumptions | This sequence is representative of how the AAL Application uses the sendBuffer operation in an asynchronous manner with buffer free enabled. | | +| Pre-conditions | At least one AAL-Profile-Instance is configured and started. At least one AAL-Profile-Queue is configured and started. Buffer(s) to be sent are allocated. | | +| Begins when | The AAL Application is ready to send buffer. | | +| Steps 1 – 3 (M) | The AAL Application calls the sendBuffer API to transfer the buffer to the AAL which will execute the sendBuffer operation.<br><br>The AAL Application thread invoking the API is returned immediately with the status of the API call, without being blocked until the completion of sendBuffer operation. | | + +| | | | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| | The AAL continues to process the operation and sends the buffers. Upon completion of sendBuffer operation, the AAL internally frees the buffer back to the buffer pool. | | +| Step 4 (O) | Once done, the AAL optionally returns the status of the operation back to the AAL Application, if the AAL Application preregisters for a callback. | | +| Ends when | sendBuffer operation has completed. | | +| Exceptions | Exceptions can occur if the sendBuffer API call fails. Status indicating failure will be returned in Step 2. | | +| Post Conditions | The AAL Application can continue processing. | | +| Traceability | To Be added later. | | + +``` + +@startuml +Autonumber +Skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +Box "O-RAN" #NavajoWhite + Participant "O-DU" as ODU << AAL-App>> +end box +Box "Cloud Platform" #lightseagreen + participant "AAL Implementation" as AAL +End box + +activate ODU + +ref over ODU, AAL +Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers +end ref + +==Asynchronous Send Buffer (with buffer free) == + +ODU -> AAL : sendBuffer +Activate AAL +note over AAL +Return immediately. +endnote + +AAL --> ODU : return status of API + +Note over AAL +Continue to process operations asynchronously +until all buffers sent. +endnote + +AAL -> AAL: free Buffer + +opt if a callback is preregistered +AAL -> ODU: execute preregistered callback function +End opt + +deactivate AAL +deactivate ODU + +@enduml + +``` + +![Sequence diagram for Asynchronous Send Buffer (with buffer free) showing interactions between O-RAN and Cloud Platform.](0a08e5ee57dd048c63e2e5be280397a1_img.jpg) + +``` + +sequenceDiagram + participant O-RAN as O-RAN + participant CP as Cloud Platform + participant AAL_O_DU as «AAL-App» O-DU + participant AAL_Impl as AAL Implementation + + O-RAN->>CP: ref Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers + O-RAN->>CP: 1 sendBuffer + CP-->>O-RAN: 2 return status of API + CP->>CP: Return immediately. + CP->>CP: Continue to process operations asynchronously until all buffers sent. + CP->>CP: 3 free Buffer + O-RAN->>CP: opt [if a callback is preregistered] 4 execute preregistered callback function + +``` + +The diagram illustrates the workflow for sending a buffer asynchronously without buffer free. It shows the interaction between the O-RAN (O-DU) and the Cloud Platform (AAL Implementation). The O-RAN sends a buffer to the AAL Implementation, which returns the status of the API. The AAL Implementation then returns immediately and continues to process operations asynchronously until all buffers are sent. Finally, the AAL Implementation sends a free buffer message back to the O-RAN. An optional step shows the AAL Implementation executing a preregistered callback function if one is present. + +Sequence diagram for Asynchronous Send Buffer (with buffer free) showing interactions between O-RAN and Cloud Platform. + +##### 5.3.3.2.4 Send Buffer Asynchronous Mode without buffer free + +**Table 5.3.3.2.4-1 : Send Buffer Asynchronous Mode without buffer free workflow steps** + +| | Evolution / Specification | <<Uses>><br>Related use | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | The AAL Application sends buffer(s) to the AAL for processing in asynchronous mode without buffer free. | | +| Actors and Roles | AAL Application: formats buffer and its content, and calls AAL to send the buffer.<br>AAL Implementation: executes sendBuffer operation. | | +| Assumptions | This sequence is representative of how the AAL Application uses the sendBuffer operation in an asynchronous manner without buffer free enabled. | | +| Pre-conditions | At least one AAL-Profile-Instance is configured and started. At least one AAL-Profile-Queue is configured and started. Buffer(s) to be sent are allocated. | | +| Begins when | The AAL Application is ready to send buffer. | | +| Steps 1-2 (M) | The AAL Application calls the sendBuffer API to transfer the buffer to the AAL which will execute the sendBuffer operation. | | + +| | | | +|-----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| | <p>The AAL Application thread invoking the API is returned immediately with the status of the API call, without being blocked until the completion of sendBuffer operation.</p> <p>The AAL continues to process the operation and sends the buffers.</p> | | +| Steps 3-4 (CM) | In case of without preregistered callback, the AAL Application, when finished with the buffer <sup>[1]</sup> , calls freeBuffer operation. The AAL returns the status of the API call immediately and internally frees the buffer upon completion of sendBuffer operation. | | +| Steps 5-7 (CM) | <p>In case of with preregistered callback, the AAL returns the status of the sendBuffer operation back to the AAL Application, once done.</p> <p>The AAL Application, when finished with the buffer <sup>[2]</sup>, calls freeBuffer operation and the AAL will free the buffer back to the buffer pool.</p> | | +| Ends when | sendBuffer operation has completed. | | +| Exceptions | Exceptions can occur if the sendBuffer API call fails. Status indicating failure will be returned in Step 2. | | +| Post Conditions | The AAL Application can continue processing. | | +| Traceability | To Be added later. | | + +Note <sup>[1]</sup>: The AAL Application should not modify the content of the buffer(s) after step 2. + +Note <sup>[2]</sup>: The AAL Application can modify the content of the buffer(s) after step 5. + +``` + +@startuml +Autonumber +Skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +Box "O-RAN" #NavajoWhite + Participant "O-DU" as ODU << AAL-App>> +end box +Box "Cloud Platform" #lightseagreen + participant "AAL Implementation" as AAL +End box + +activate ODU + +ref over ODU, AAL +Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers +end ref + +==Asynchronous Send Buffer (without buffer free) == + +ODU -> AAL : sendBuffer +activate AAL +note over AAL +return immediately. +endnote + +AAL --> ODU : return status of API + +Note over AAL +Continue to process operations asynchronously + +``` + +``` + +until all buffers sent. +endnote + +alt without callback + ODU -> AAL: freeBuffer + AAL --> ODU : success/failure + + Note over AAL + Internally buffer is freed when sendBuffer completes. +endnote + +else with preregistered callback + AAL --> ODU: execute preregistered callback function + deactivate AAL + + ODU -> AAL: freeBuffer + activate AAL + AAL --> ODU : success/failure + deactivate AAL +end +deactivate ODU +@enduml + +``` + +![Sequence diagram showing the interaction between O-RAN and Cloud Platform for asynchronous send buffer operations.](72687c496893ef673bb5cf9bd52fd12e_img.jpg) + +The diagram illustrates the sequence of operations for an asynchronous send buffer without a buffer free callback. It involves two main entities: O-RAN (represented by «AAL-App» O-DU) and Cloud Platform (represented by AAL Implementation). + +**Sequence of Operations:** + +- ref:** Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers +- Asynchronous Send Buffer (without buffer free)** (Double horizontal line separator) +- 1 sendBuffer:** O-RAN sends a message to Cloud Platform. +- return immediately:** Cloud Platform returns immediately. +- 2 return status of API:** Cloud Platform returns status to O-RAN. +- Continue to process operations asynchronously until all buffers sent.** (Note block) +- alt:** + - [without callback]** + - 3 freeBuffer:** O-RAN sends freeBuffer to Cloud Platform. + - 4 success/failure:** Cloud Platform returns success/failure to O-RAN. + - Internally buffer is freed when sendBuffer completes.** (Note block) + - [with preregistered callback]** + - 5 execute preregistered callback function:** Cloud Platform executes callback function on O-RAN. + - 6 freeBuffer:** O-RAN sends freeBuffer to Cloud Platform. + - 7 success/failure:** Cloud Platform returns success/failure to O-RAN. + +Sequence diagram showing the interaction between O-RAN and Cloud Platform for asynchronous send buffer operations. + +##### 5.3.3.2.5 Receive Buffer Synchronous Mode with non-NULL buffer\_handle(s) input + +**Table 5.3.3.2.5-1 : Receive Buffer Synchronous Mode with non-NULL buffer\_handle(s) input workflow steps** + +| | Evolution / Specification | <<Uses>><br>Related use | +|------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | The AAL Application (e.g., O-DU) receives buffer(s) from the AAL in synchronous mode with non-NULL buffer_handle(s) input. | | +| Actors and Roles | AAL Application: calls AAL to receive the buffer.<br>AAL Implementation: executes receiveBuffer operation. | | +| Assumptions | This sequence is representative of how the AAL Application uses the receiveBuffer operation in a synchronous manner with non-NULL buffer handle(s) input. | | +| Pre-conditions | At least one AAL-Profile-Instance is configured and started. At least one AAL-Profile-Queue is configured and started. Receive buffer(s) are allocated. | | +| Begins when | The AAL Application is ready to receive buffer. | | +| Steps 1 – 2 (M) | The AAL Application calls the receiveBuffer API to receive buffer content from the AAL which will execute the receiveBuffer operation. The AAL Application thread invoking the API is blocked waiting for the receiveBuffer operation to complete.<br><br>Once done, the AAL returns the status of the operation back to the AAL Application and unblock the AAL Application call thread process. | | +| Steps 3 - 4 (M) | The AAL Application, when finished with the buffer, calls freeBuffer operation and the AAL will free the buffer back to the buffer pool. | | +| Ends when | receiveBuffer operation has completed. | | +| Exceptions | Exceptions can occur if the receiveBuffer operation fails. Status indicating failure will be returned in Step 2. | | +| Post Conditions | The AAL Application can continue processing. | | +| Traceability | To Be added later. | | + +``` + +@startuml +Autonumber +Skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +autoactivate on + +Box "O-RAN" #NavajoWhite + Participant "O-DU" as ODU << AAL-App>> +end box +Box "Cloud Platform" #lightseagreen + participant "AAL Implementation" as AAL +End box + +activate ODU + +ref over ODU, AAL + +``` + +##### Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers + +``` +==Synchronous Receive Buffer== +``` + +``` +ODU -> AAL : receiveBuffer +deactivate ODU +``` + +``` +note over AAL +Perform operations and receive all buffers. +Return when all buffers are sent. +Endnote +``` + +``` +AAL --> ODU : return status +activate ODU +ODU -> AAL: freeBuffer +AAL --> ODU : success/failure +``` + +``` +deactivate ODU +@enduml +``` + +![Sequence diagram showing the interaction between O-RAN and Cloud Platform for a Synchronous Receive Buffer.](4fa46513edc2038121073b5baea209d7_img.jpg) + +``` + +sequenceDiagram + participant O_RAN as O-RAN + participant Cloud_Platform as Cloud Platform + participant AAL_App as «AAL-App» O-DU + participant AAL_Implementation as AAL Implementation + + O_RAN->>Cloud_Platform: ref + O_RAN->>Cloud_Platform: Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers + O_RAN->>Cloud_Platform: 1 receiveBuffer + activate AAL_Implementation + Note over AAL_Implementation: Perform operations and receive all buffers. +Return when all buffers are sent. + Cloud_Platform-->>O_RAN: 2 return status + deactivate AAL_Implementation + O_RAN->>Cloud_Platform: 3 freeBuffer + activate AAL_Implementation + Cloud_Platform-->>O_RAN: 4 success/failure + deactivate AAL_Implementation + +``` + +The diagram illustrates the sequence of operations for a Synchronous Receive Buffer. It shows the interaction between the O-RAN (represented by the «AAL-App» O-DU) and the Cloud Platform (represented by the AAL Implementation). The process begins with a reference to Section 5.3.3.1, followed by the O-RAN sending a 'receiveBuffer' message to the Cloud Platform. The Cloud Platform then performs operations and returns a 'return status' to the O-RAN. Finally, the O-RAN sends a 'freeBuffer' message to the Cloud Platform, which returns a 'success/failure' status. + +Sequence diagram showing the interaction between O-RAN and Cloud Platform for a Synchronous Receive Buffer. + +![Sequence diagram showing the workflow for Receive Buffer Synchronous Mode with NULL buffer_handle(s) input. The diagram involves two main components: O-RAN (containing «AAL-App» O-DU) and Cloud Platform (containing AAL Implementation). A reference is made to Section 5.3.3.1. The sequence of messages is: 1. receiveBuffer (O-RAN to Cloud Platform), 2. return status (Cloud Platform to O-RAN), 3. freeBuffer (O-RAN to Cloud Platform), and 4. success/failure (Cloud Platform to O-RAN). A note indicates that the AAL Implementation performs operations and receives all buffers, returning when all buffers are sent.](202374af27333eb909b509122900acd0_img.jpg) + +``` + +sequenceDiagram + participant O-RAN as O-RAN + participant Cloud Platform as Cloud Platform + O-RAN->>Cloud Platform: 1 receiveBuffer + activate Cloud Platform + Note over Cloud Platform: Perform operations and receive all buffers. Return when all buffers are sent. + Cloud Platform-->>O-RAN: 2 return status + deactivate Cloud Platform + O-RAN->>Cloud Platform: 3 freeBuffer + activate Cloud Platform + Cloud Platform-->>O-RAN: 4 success/failure + deactivate Cloud Platform + +``` + +Sequence diagram showing the workflow for Receive Buffer Synchronous Mode with NULL buffer\_handle(s) input. The diagram involves two main components: O-RAN (containing «AAL-App» O-DU) and Cloud Platform (containing AAL Implementation). A reference is made to Section 5.3.3.1. The sequence of messages is: 1. receiveBuffer (O-RAN to Cloud Platform), 2. return status (Cloud Platform to O-RAN), 3. freeBuffer (O-RAN to Cloud Platform), and 4. success/failure (Cloud Platform to O-RAN). A note indicates that the AAL Implementation performs operations and receives all buffers, returning when all buffers are sent. + +##### 5.3.3.2.6 Receive Buffer Synchronous Mode with NULL buffer\_handle(s) input + +**Table 5.3.3.2.6-1: Receive Buffer Synchronous Mode with NULL buffer\_handle(s) input workflow steps** + +| | Evolution / Specification | <<Uses>><br>Related use | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | The AAL Application (e.g., O-DU) receives buffer(s) from the AAL in synchronous mode with NULL buffer_handle(s) input. | | +| Actors and Roles | AAL Application: calls AAL to receive the buffer.<br>AAL Implementation: executes receiveBuffer operation. | | +| Assumptions | This sequence is representative of how the AAL Application uses the receiveBuffer operation in a synchronous manner with NULL buffer_handle(s) input. | | +| Pre-conditions | At least one AAL-Profile-Instance is configured and started. At least one AAL-Profile-Queue is configured and started. | | +| Begins when | The AAL Application is ready to receive buffer. | | +| Steps 1 – 2 (M) | The AAL Application calls the receiveBuffer API to receive buffer content from the AAL which will execute the receiveBuffer operation including the allocation of the buffers. The AAL Application thread invoking the API is blocked waiting for the receiveBuffer operation to complete.<br><br>Once done, the AAL returns the status of the operation back to the AAL Application and unblock the AAL Application call thread process. | | +| Steps 3 - 4 (M) | The AAL Application, when finished with the buffer, calls freeBuffer operation and the AAL will free the buffer back to the buffer pool. | | +| Ends when | receiveBuffer operation has completed. | | +| Exceptions | Exceptions can occur if the receiveBuffer operation fails. Status indicating failure will be returned in Step 2. | | + +| | | | +|-----------------|----------------------------------------------|--| +| Post Conditions | The AAL Application can continue processing. | | +| Traceability | To Be added later. | | + +``` + +@startuml +Autonumber +Skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +autoactivate on + +Box "O-RAN" #NavajoWhite + Participant "O-DU" as ODU << AAL-App >> +end box +Box "Cloud Platform" #lightseagreen + participant "AAL Implementation" as AAL +End box + +activate ODU + +ref over ODU, AAL +Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers +end ref + +==Synchronous Receive Buffer== + +ODU -> AAL : receiveBuffer +deactivate ODU + +AAL -> AAL : allocate buffer +note over AAL +Perform operations and receive all buffers. +Return when all buffers are sent. +endnote + +AAL --> ODU : return status +deactivate AAL + +activate ODU +ODU -> AAL: freeBuffer +AAL --> ODU : success/failure + +deactivate ODU +@enduml + +``` + +![Sequence diagram for Synchronous Receive Buffer workflow. The diagram shows interactions between O-RAN (containing «AAL-App» O-DU) and Cloud Platform (containing AAL Implementation). A reference to Section 5.3.3.1 is provided. The workflow steps are: 1. receiveBuffer (O-RAN to Cloud Platform), 2. allocate buffer (Cloud Platform self-call), 3. return status (Cloud Platform to O-RAN), 4. freeBuffer (O-RAN to Cloud Platform), and 5. success/failure (Cloud Platform to O-RAN). A note indicates: 'Perform operations and receive all buffers. Return when all buffers are sent.'](e176807f1e086f55c30bf9e34817f789_img.jpg) + +``` + +sequenceDiagram + participant O-RAN as O-RAN + participant CP as Cloud Platform + participant AAL_Implementation as AAL Implementation + + O-RAN->>CP: 1 receiveBuffer + activate CP + CP->>AAL_Implementation: 2 allocate buffer + activate AAL_Implementation + AAL_Implementation-->>CP: + deactivate AAL_Implementation + CP-->>O-RAN: 3 return status + deactivate CP + O-RAN->>CP: 4 freeBuffer + activate CP + CP-->>O-RAN: 5 success/failure + deactivate CP + +``` + +Sequence diagram for Synchronous Receive Buffer workflow. The diagram shows interactions between O-RAN (containing «AAL-App» O-DU) and Cloud Platform (containing AAL Implementation). A reference to Section 5.3.3.1 is provided. The workflow steps are: 1. receiveBuffer (O-RAN to Cloud Platform), 2. allocate buffer (Cloud Platform self-call), 3. return status (Cloud Platform to O-RAN), 4. freeBuffer (O-RAN to Cloud Platform), and 5. success/failure (Cloud Platform to O-RAN). A note indicates: 'Perform operations and receive all buffers. Return when all buffers are sent.' + +##### 5.3.3.2.7 Receive Buffer Asynchronous Mode with non-NULL buffer\_handle(s) input + +**Table 5.3.3.2.7-1: Receive Buffer Asynchronous Mode with non-NULL buffer\_handle(s) input workflow steps** + +| | Evolution / Specification | <<Uses>><br>Related use | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Goal | The AAL Application (e.g., O-DU) receives buffer(s) from the AAL in asynchronous mode with non-NULL buffer_handle(s) input. | | +| Actors and Roles | AAL Application: calls AAL to receive the buffer.<br>AAL Implementation: executes receiveBuffer operation. | | +| Assumptions | This sequence is representative of how the AAL Application uses the receiveBuffer operation in an asynchronous manner with non-NULL buffer_handle(s) input. | | +| Pre-conditions | At least one AAL-Profile-Instance is configured and started. At least one AAL-Profile-Queue is configured and started. Receive buffer(s) are allocated. | | +| Begins when | The AAL Application is ready to receive buffer. | | +| Step 1-4 (CM) | In case of without callback, the AAL Application calls the receiveBuffer API to receive buffer content from the AAL which will execute the receiveBuffer | | + +| | | | +|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| | operation. In the case no buffers are ready to be received the AAL Implementation returns immediately indicating no buffers were received. | | +| | The AAL Application calls the receiveBuffer API to receive buffer content from the AAL which will execute the receiveBuffer operation. The AAL returns the status of the operation and the number of buffers received. | | +| Steps 5-8 (CM) | In case of with preregistered callback, the AAL Application calls the receiveBuffer API to receive buffer content from the AAL which will execute the receiveBuffer operation. In the case no buffers are ready to be received the AAL Implementation returns immediately indicating the status of the operation. The AAL Implementation waits asynchronously for buffers to be received. Upon receiving buffers, the pre-registered callback function is executed to asynchronously inform the AAL Application that new buffers have been received. | | +| Steps 9-10 (M) | The AAL Application, when finished with the buffer, calls freeBuffer operation and the AAL will free the buffer back to the buffer pool. | | +| Ends when | receiveBuffer operation has completed. | | +| Exceptions | Exceptions can occur if the receiveBuffer operation fails. Status indicating failure will be returned in Step 1 or 5 or 8. | | +| Post Conditions | The AAL Application can continue processing. | | +| Traceability | To Be added later. | | + +``` + +@startuml +Autonumber +Skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +autoactivate on + +Box "O-RAN" #NavajoWhite + Participant "O-DU" as ODU << AAL-App >> +end box +Box "Cloud Platform" #lightseagreen + participant "AAL Implementation" as AAL +End box + +activate ODU + +ref over ODU, AAL +Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers +end ref + +==Asynchronous Receive Buffer== + +alt without callback + +ODU -> AAL : receiveBuffer +deactivate ODU + +note over AAL +If no buffers received return immediately. +In Asynchronous mode with no callback receive +API behaves in a poll manner. +endnote + +``` + +``` +AAL --> ODU : (number of buffers = 0) +activate ODU + +ODU -> AAL : receiveBuffer +deactivate ODU +AAL --> ODU : success (number of buffers) +activate ODU + +else with preregistered callback + +ODU -> AAL : receiveBuffer +Activate AAL + +AAL --> ODU : return status +AAL -> AAL : wait for receive buffers + +note over AAL +AAL executes receive operation. +endnote + +AAL --> ODU: execute preregistered callback function +deactivate AAL +end + +activate ODU +ODU -> AAL: freeBuffer +AAL --> ODU : success/failure + +deactivate ODU +@enduml +``` + +![Sequence diagram for Asynchronous Receive Buffer API workflow. The diagram shows interactions between O-RAN (AAL-App O-DU) and Cloud Platform (AAL Implementation). It includes a reference to Section 5.3.3.1, an asynchronous receive buffer section, and two alternative flows: one without a callback and one with a preregistered callback. The 'without callback' flow shows steps 1 (receiveBuffer), 2 (number of buffers = 0), 3 (receiveBuffer), and 4 (success). The 'with preregistered callback' flow shows steps 5 (receiveBuffer), 6 (return status), 7 (wait for receive buffers), 8 (execute preregistered callback function), 9 (freeBuffer), and 10 (success/failure). A note indicates that if no buffers are received, the return is immediate in asynchronous mode without a callback. Another note states that the AAL Implementation executes the receive operation.](98de20f3b94513c9912b691e57d5cb30_img.jpg) + +``` + +sequenceDiagram + participant O-RAN as «AAL-App» O-DU + participant Cloud Platform as AAL Implementation + + ref Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers + alt Asynchronous Receive Buffer + alt [without callback] + O-RAN->>Cloud Platform: 1 receiveBuffer + Cloud Platform-->>O-RAN: 2 (number of buffers = 0) + O-RAN->>Cloud Platform: 3 receiveBuffer + Cloud Platform-->>O-RAN: 4 success (number of buffers) + and [with preregistered callback] + O-RAN->>Cloud Platform: 5 receiveBuffer + Cloud Platform-->>O-RAN: 6 return status + Cloud Platform->>Cloud Platform: 7 wait for receive buffers + Cloud Platform-->>O-RAN: 8 execute preregistered callback function + O-RAN->>Cloud Platform: 9 freeBuffer + Cloud Platform-->>O-RAN: 10 success/failure + end + end + +``` + +If no buffers received return immediately. In Asynchronous mode with no callback receive API behaves in a poll manner. + +AAL executes receive operation. + +Sequence diagram for Asynchronous Receive Buffer API workflow. The diagram shows interactions between O-RAN (AAL-App O-DU) and Cloud Platform (AAL Implementation). It includes a reference to Section 5.3.3.1, an asynchronous receive buffer section, and two alternative flows: one without a callback and one with a preregistered callback. The 'without callback' flow shows steps 1 (receiveBuffer), 2 (number of buffers = 0), 3 (receiveBuffer), and 4 (success). The 'with preregistered callback' flow shows steps 5 (receiveBuffer), 6 (return status), 7 (wait for receive buffers), 8 (execute preregistered callback function), 9 (freeBuffer), and 10 (success/failure). A note indicates that if no buffers are received, the return is immediate in asynchronous mode without a callback. Another note states that the AAL Implementation executes the receive operation. + +##### 5.3.3.2.8 Receive Buffer Asynchronous Mode with NULL buffer\_handle input + +**Table 5.3.3.2.8-1 : Receive Buffer Asynchronous Mode with NULL buffer\_handle input workflow steps** + +| | Evolution / Specification | <<Uses>><br>Related use | +|--|---------------------------|-------------------------| +|--|---------------------------|-------------------------| + +| | | | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| Goal | The AAL Application (e.g., O-DU) receives buffer(s) from the AAL in asynchronous mode with NULL buffer_handle input. | | +| Actors and Roles | AAL Application: calls AAL to receive the buffer.<br><br>AAL Implementation: executes receiveBuffer operation. | | +| Assumptions | This sequence is representative of how the AAL Application uses the receiveBuffer operation in an asynchronous manner with NULL buffer_handle input. | | +| Pre-conditions | At least one AAL-Profile-Instance is configured and started. At least one AAL-Profile-Queue is configured and started. | | +| Begins when | The AAL Application is ready to receive buffer. | | +| Steps 1-5 (CM) | In case of with callback, the AAL Application calls the receiveBuffer API to receive buffer content from the AAL which will execute the receive. In the case no buffers are ready to be received the AAL Implementation returns immediately indicating no buffers were received.<br><br>The AAL Application calls the receiveBuffer API to receive buffer content from the AAL which will execute the receiveBuffer operation including the allocation of the buffers. The AAL returns the status of the operation, newly allocated buffer_handle(s) and the number of buffers received. | | +| Steps 6-10 (CM) | In case of with preregistered callback, the AAL Application calls the receiveBuffer API to receive buffer content from the AAL which will execute the receiveBuffer operation. In the case no buffers are ready to be received the AAL Implementation returns immediately indicating the status of the operation.<br><br>The AAL Implementation waits asynchronously for buffers to be received. The AAL allocates the buffers. Upon receiving buffers, the pre-registered callback function is executed to asynchronously inform the AAL Application that new buffers have been received. | | +| Steps 11-12 (M) | The AAL Application, when finished with the buffer, calls freeBuffer operation and the AAL will free the buffer back to the buffer pool. | | +| Ends when | receiveBuffer operation has completed. | | +| Exceptions | Exceptions can occur if the receiveBuffer operation fails. Status indicating failure will be returned in Step 1 or 5 or 8. | | +| Post Conditions | The AAL Application can continue processing. | | +| Traceability | To Be added later. | | + +``` + +@startuml +Autonumber +Skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 +autoactivate on + +Box "O-RAN" #NavajoWhite + Participant "O-DU" as ODU << AAL-App>> +end box +Box "Cloud Platform" #lightseagreen + +``` + +``` + + participant "AAL Implementation" as AAL +End box + +activate ODU + +ref over ODU, AAL +Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers +end ref + +==Asynchronous Receive Buffer== + +alt without callback + +ODU -> AAL : receiveBuffer +deactivate ODU + +note over AAL +If no buffers received return immediately. +In Asynchronous mode with no callback receive +API behaves in a poll mode manner. +endnote + +AAL --> ODU : (number of buffers = 0) +activate ODU + +ODU -> AAL : receiveBuffer +deactivate ODU +AAL -> AAL : Allocate buffer(s) +AAL --> ODU : success (number of buffers) +activate ODU + +else with preregistered callback + +ODU -> AAL : receiveBuffer + +AAL --> ODU : return status +AAL -> AAL : wait for receive buffers +AAL -> AAL : Allocate buffer(s) +note over AAL +AAL executes receive operation. +endnote + +AAL --> ODU : execute preregistered callback function +deactivate AAL +deactivate AAL + +end + +activate ODU +ODU -> AAL : freeBuffer +AAL --> ODU : success/failure + +deactivate ODU +@enduml + +``` + +![Sequence diagram for Asynchronous Receive Buffer API between O-RAN and Cloud Platform.](959ae85c474b89c55a65fc5a096c81bc_img.jpg) + +The diagram illustrates the sequence of operations for the Asynchronous Receive Buffer API between the O-RAN and the Cloud Platform. + +**Participants:** + +- O-RAN:** Contains the «AAL-App» O-DU. +- Cloud Platform:** Contains the AAL Implementation. + +**Sequence of Operations:** + +- ref:** Section 5.3.3.1 Creating Buffer Pools and Allocating Buffers. +- alt [without callback]:** + - 1 receiveBuffer:** O-RAN sends to Cloud Platform. + - 2 (number of buffers = 0):** Cloud Platform returns to O-RAN. + - 3 receiveBuffer:** O-RAN sends to Cloud Platform. + - 4 Allocate buffer(s):** Cloud Platform performs internal action. + - 5 success (number of buffers):** Cloud Platform returns to O-RAN. +- [with preregistered callback]:** + - 6 receiveBuffer:** O-RAN sends to Cloud Platform. + - 7 return status:** Cloud Platform returns to O-RAN. + - 8 wait for receive buffers:** Cloud Platform performs internal action. + - 9 Allocate buffer(s):** Cloud Platform performs internal action. + - AAL executes receive operation:** Cloud Platform performs internal action. + - 10 execute preregistered callback function:** Cloud Platform returns to O-RAN. +- 11 freeBuffer:** O-RAN sends to Cloud Platform. +- 12 success/failure:** Cloud Platform returns to O-RAN. + +**Notes:** + +- If no buffers received return immediately. In Asynchronous mode with no callback receive API behaves in a poll mode manner. +- AAL executes receive operation. + +Sequence diagram for Asynchronous Receive Buffer API between O-RAN and Cloud Platform. + +## 5.4 AALI-C-App API details + +### 5.4.1 Capabilities discovery and configuration + +#### 5.4.1.1 initAal + +Description: An AAL Application initializes the AAL Implementation. + +Pre-conditions: AAL Application is started. + +Triggers: Executed once by the AAL Application + +Frequency: AAL Application Initialization time. + +**Table 5.4.1.1-1: initAal operation** + +| Operation | Direction | +|-----------|------------------------| +| initAal | AAL Application => AAL | + +**Table 5.4.1.1-2: initAal Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|----------------------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| lpu_identifiers | 1..N | List Values | M | Optional list provided by DMS to the AAL Application that identifies the O-Cloud Resources and associated attributes that the DMS has assigned to and can be used by the AAL Application | +| vendor_specific | 0..N | List Key/Value pairs | | List of vendor specific attributes provided by the AAL Application. The AAL Application can obtain these parameters via the DMS or through another mechanism. | + +**Table 5.4.1.1-3: initAal Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|-----------------------------|-----------|-------------------------------------| +| status_of_operation | | Reference WG10 object model | M | Returns the status of the procedure | + +#### 5.4.1.2 cleanupAal + +Description: This function must be called to allow the AAL implementation release any internal resources that the AAL implementation has allocated during initAal. After this call no other AALI-C-App API calls may be made. + +Pre-conditions: initAal has been executed. + +Triggers: Executed once by the AAL Application + +Frequency: AAL Application termination time. + +**Table 5.4.1.2-1: cleanupAal Operation** + +| Operation | Direction | +|-----------|-----------| +|-----------|-----------| + +| | | +|------------|------------------------| +| cleanupAal | AAL Application => AAL | +|------------|------------------------| + +**Table 5.4.1.2-2: cleanupAal Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|-----------|-----------|-------------| +| NULL | 0 | | | | + +**Table 5.4.1.2-3: cleanupAal Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|-----------------------------|-----------|-------------------------------------| +| status_of_operation | | Reference WG10 object model | M | Returns the status of the procedure | + +#### 5.4.1.3 getAalLpuInfo + +Description: An AAL Application queries the handle and capabilities of the AAL-LPU(s) assigned to the AAL Application. AAL-LPUs may provide different capabilities such as different AAL Profiles can be supported by the AAL-LPUs that includes different types of AAL-Profile-Instances and AAL-Profile-Queue(s). The aal-lpu-handle is unique between the AAL Application and the AAL-LPUs assigned to the AAL Application. The aal-lpu-handle is generated by the AAL Implementation. + +Pre-conditions: AAL Application has at least one AAL-LPU assigned and available for use. + +Triggers: On demand request from the AAL Application + +Frequency: AAL Application Initialization time. + +**Table 5.4.1.1-1: getAalLpuInfo operation** + +| Operation | Direction | +|---------------|---------------------------| +| getAalLpuInfo | AAL => AAL Implementation | + +**Table 5.4.1.1-2: getAalLpuInfo Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|-----------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| aal_lpu_handle | 0 to 1 | | O | If supplied, the capabilities of only the AAL-LPU associated with the Handle is requested. If omitted, the capabilities of all the AAL-LPUs assigned to the AAL Application is requested. | + +**Table 5.4.1.1-3: getAalLpuInfo Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|-----------------------------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| aal-lpu-cap-struct | 0 to many | struct | O | Struct containing the aal-lpu-handle and the capabilities supported by this AAL-LPU including AAL Profile type(s) that are available to the calling AAL Application. | +| status_of_operation | | Reference WG10 object model | M | Returns the status of the procedure | + +NOTE List of AAL Profile types to be defined, e.g. High-PHY. Types should also be versioned, e.g. High-PHY.V1 + +### 5.4.2 AALI-C-App Configuration Services + +Before using AAL-Profile-Instance services the AAL Application must first create the AAL-Profile-Instance, then configure the AAL-Profile-Instance and the AAL-Profile-Queue(s). + +#### 5.4.2.1 createAalProfileInstance + +Description: The AAL Application creates an AAL-Profile-Instance on the AAL-LPU. The AAL-Profile-Instance is created based on the AAL Profile type that is requested by the AAL Application. The list of available AAL Profile type(s) is provided by the AALI in the getAalLpuInfo response. After successful creation, the AAL-Profile-Instance is in a 'in use, stopped' state. The AAL Application may now configure the AAL-Profile-Instance, AAL-Profile-Queue(s) and start the AAL-Profile-Instance. + +This procedure may be repeated by the AAL Application in order to create multiple AAL-Profile-Instances, of the same or different AAL Profile types. + +Pre-conditions: AAL Application has at least 1 AAL-LPU assigned and available for use. The AAL Profile type that is requested to be created is provided by the AAL-LPU (listed in the AAL-LPU-Capability struct of the getAalLpuInfo response operation). + +Triggers: On demand request from the AAL Application + +Frequency: Infrequent. + +**Table 5.4.2.1-1: createAalProfileInstance Operator** + +| Operation | Direction | +|--------------------------|---------------------------------------| +| createAalProfileInstance | AAL Application => AAL Implementation | + +**Table 5.4.2.1-2: createAalProfileInstance Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------------|-------------|-----------|-----------|-----------------------------------------------------------------------------------------------------------------------| +| aal_lpu_handle | 1 | N/A | M | The Handle of the AAL-LPU to create the AAL-Profile instance on. | +| aal_profile_instance_type | 1 | tbd | M | The type (and version) of an AAL-Profile-Instance (returned in the getAalLpuInfo operation) to create on this AAL-LPU | + +**Table 5.4.2.1-3: createAalProfileInstance Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------------|-------------|-----------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Status | 1 | | M | Result of the createProfileInstance operation | +| aal_profile_instance_handle | 1 | | C | Handle of the AAL-Profile instance created in this create AAL-Profile-Instance Request.<br><br>This field is only present if the createProfileInstance operation is successful | +| aal_profile_instance_config | 1 | Struct | C | Structure containing the default settings of the AAL-Profile-Instance. This field is only present if the createProfileInstance operation is successful. | + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|--------------------------------------|-----------|-----------------------------------------------| +| Status | 1 | | M | Result of the createProfileInstance operation | +| status_of_operation | | Reference<br>WG10<br>object<br>model | M | Returns the status of the procedure | + +#### 5.4.2.2 setAalProfileInstanceConfig + +Description: The AAL Application configures the AAL-Profile-Instance on the AAL-LPU for a specific AAL Profile configuration for use by the AAL Application. + +Pre-conditions: AAL Application has successfully created the AAL-LPU-Profile instance on the AAL-LPU. The AAL-Profile-Instance is not started. + +Triggers: On demand request from the AAL Application + +Frequency: Infrequent. + +**Table 5.4.2.2-1: setAalProfileInstanceConfig Operation** + +| Operation | Direction | +|--------------------------|---------------------------------------| +| setProfileInstanceConfig | AAL Application => AAL Implementation | + +**Table 5.4.2.2-2: setAalProfileInstanceConfig Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------------|-------------|-----------|-----------|-----------------------------------------------------------------------| +| aal_profile_instance_handle | 1 | N/A | M | The Handle of the AAL-Profile-Instance to be configured. | +| aal_profile_instance_config | 1 | struct | M | Structure containing the AAL-Profile-Instance configuration to apply. | + +**Table 5.4.2.2-3: setAalProfileInstanceConfig Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|------------------------------------------------|-----------|-------------------------------------| +| status_of_operation | | <i>Reference<br/>WG10<br/>object<br/>model</i> | M | Returns the status of the procedure | + +#### 5.4.2.3 deleteAalProfileInstance + +Description: The AAL Application may delete the AAL-Profile-Instance when it no longer requires it. For example, if a cell is deleted from the O-DU by upper layers or the OAM system, the AAL-Profile-Instance resources used to offload that cell can be deleted. After deleting the AAL-Profile-Instance, that AAL-Profile-Instance is no longer usable by the AAL Application. + +Pre-conditions: The AAL Application has successfully stopped the AAL-Profile-Instance. + +Triggers: On demand request from the AAL Application + +Frequency: Infrequent. + +**Table 5.4.2.3-1: deleteAalProfileInstance Operation** + +| Operation | Direction | +|--------------------------|---------------------------------------| +| deleteAalProfileInstance | AAL Application => AAL Implementation | + +**Table 5.4.2.3-2: deleteAalProfileInstance Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------------|-------------|-----------|-----------|---------------------------------------------------| +| aal_profile_instance_handle | 1 | N/A | M | The Handle of the AAL-Profile-Instance to delete. | + +**Table 5.4.2.3-3: deleteAalProfileInstance Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|------------------------------------|-----------|-------------------------------------| +| status_of_operation | | <i>Reference WG10 object model</i> | M | Returns the status of the procedure | + +#### 5.4.2.4 setAalProfileQueueConfig + +NOTE: Use of AAL-Profile-Queue operations for user plane data transfer and buffer API operations needs to be clarified. + +Description: The AAL Application configures the AAL-Profile-Queue on the AAL-Profile-Instance. + +If no AAL-Profile-Queue Handle is included, this operation will create and configure a new AAL-Profile-Queue. The response will include the AAL-Profile-Queue Handle for the AAL-Profile-Queue. To add an AAL-Profile-Queue to an AAL-Profile-Instance, the AAL-Profile-Instance must be stopped by the AAL Application. + +If an AAL-Profile-Queue Handle is supplied, the configuration of the AAL-Profile-Queue identified by the AAL-Profile-Queue Handle is modified with the supplied configuration. Any items already on the queue are deleted when this operation is called. The AAL-Profile-Queue must be in the stopped state. + +Pre-conditions: AAL-Profile-Instance has already successfully been created in the AAL-LPU. The AAL Application has successfully configured the AAL-Profile-Instance. The AAL-Profile-Queue (if already existing) is in the stopped state. To add an AAL-Profile-Queue to an AAL-Profile-Instance, the AAL-Profile-Instance must be stopped by the AAL Application. To re-configure an existing AAL-Profile-Queue on an AAL-Profile-Instance, the AAL-Profile-Instance does not need to be stopped by the AAL Application. + +Triggers: On demand request from the AAL Application + +Frequency: Infrequent. + +**Table 5.4.2.4-1: setAalProfileQueueConfig Operation** + +| Operation | Direction | +|--------------------------|---------------------------------------| +| setAalProfileQueueConfig | AAL Application => AAL Implementation | + +**Table 5.4.2.4-2: setAalProfileQueueConfig Input Parameter** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------------|-------------|-----------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| aal-profile-instance-handle | 1 | | M | The Handle of the AAL-Profile-Instance | +| aal_profile_queue-handle | 1 | N/A | O | If this field is included, the operation is for an existing AAL-Profile-Queue.<br><br>If this field is omitted, a new AAL-Profile-Queue is being configured. | +| aal_profile_queue-config | 1 | struct | M | Structure containing the AAL-Profile-Queue configuration to apply. E.g.<br><br>Direction (Input or Output);<br><br>Max number of entries permitted.<br><br>Queue priority (relative to the other queues of the same direction associated with this AAL-Profile-Instance) | + +**Table 5.4.2.4-2: setAalProfileQueueConfig Output Parameter** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|--------------------------|-------------|------------------------------------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------| +| status_of_operation | | <i>Reference WG10 object model</i> | M | Returns the status of the procedure | +| aal_profile_queue-handle | 0 to 1 | | C | If no AAL-Profile-Queue Handle was included in the request, a new AAL-Profile-Queue Handle is returned if the operation was successful. | + +#### 5.4.2.5 getAalProfileQueueConfig + +Description: The AAL Application may query the current AAL-Profile-Instance queue configuration. + +Pre-conditions: AAL-Profile-Instance has already successfully been created in the AAL-LPU. The AAL Application has successfully created the AAL-Profile-Instance and the AAL-Profile-Queue. + +Triggers: On demand request from the AAL Application + +Frequency: N/A + +**Table 5.4.2.5-1: getAalProfileQueueConfig Operation** + +| Operation | Direction | +|--------------------------|---------------------------------------| +| getAalProfileQueueConfig | AAL Application => AAL Implementation | + +**Table 5.4.2.5-2: getAalProfileQueueConfig Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|--------------------------|-------------|-----------|-----------|----------------------------------------------------| +| aal_profile_queue-handle | 1 | N/A | | The handle of the AAL-Profile-Queue to be queried. | + +**Table 5.4.2.5-3: getAalProfileQueueConfig Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|--------------------------|-------------|------------------------------------|-----------|--------------------------------------------------------------------------| +| status_of_operation | | <i>Reference WG10 object model</i> | M | Returns the status of the procedure | +| aal_profile_queue_config | 1 | structure | C | On success the struct that contains the AAL-Profile-Queue configuration. | + +#### 5.4.2.6 getAalProfileInstanceConfig + +Description: The AAL Application may query the current configuration of the AAL-Profile-Instance. + +Pre-conditions: AAL Application has successfully created the AAL-LPU-Profile instance on the AAL-LPU. + +Triggers: On demand request from the AAL Application. + +Frequency: Infrequent. + +**Table 5.4.2.2-1: getAalProfileInstanceConfig Operation** + +| Operation | Direction | +|-----------------------------|---------------------------------------| +| getAalProfileInstanceConfig | AAL Application => AAL Implementation | + +**Table 5.4.2.2-2: getAalProfileInstanceConfig Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------------|-------------|-----------|-----------|----------------------------------------------------------| +| aal_profile_instance_handle | 1 | N/A | M | The handle of the AAL-Profile-Instance to be configured. | + +**Table 5.4.2.2-3: getAalProfileInstanceConfig Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------------|-------------|------------------------------------|-----------|-----------------------------------------------------------------------| +| aal_profile_instance_config | 1 | struct | M | Structure containing the AAL-Profile-Instance configuration to apply. | +| status_of_operation | | <i>Reference WG10 object model</i> | M | Returns the status of the procedure | + +### 5.4.3 AALI-C-App Transport Operations + +#### 5.4.3.1 createBufferPool + +Description: The createBufferPool operation shall support creation of N buffer pools ( $N \geq 1$ ) of a specific buffer type, with buffer read/write access to the AAL Application. + +- The AAL Application shall have the flexibility to invoke the createBufferPool operation either one time, or multiple times, to request creation of buffer pool(s) with multiple buffer sizes. +- The AAL Application shall invoke the createBufferPool operation multiple times for creation of buffer pools of different buffer types. +- The AAL Application shall not assume buffers in created buffer pools to be in a specific memory state (e.g., zero 'ed buffer). +- Buffer pool(s) and buffers are sharable by AAL-LPU(s). + - FFS: support for inter-accelerator buffer pool sharing. + +Pre-conditions: AAL Implementation is initialized. + +Triggers: On demand request from the AAL Application + +Frequency: No restriction + +**Table 5.4.3.1-1: createBufferPool Operation** + +| Operation | Direction | +|------------------|---------------------------------------| +| createBufferPool | AAL Application => AAL Implementation | + +**Table 5.4.3.1-2: createBufferPool Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|------------------------|-------------|-----------|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| number_of_buffer_pools | 1 | integer | M | Indicates the number of buffer pool(s) creation requested by the AAL Application | +| buffer_type | N | integer | M | Indicates the type(s) of content that can be placed in buffers allocated from the buffer pool(s).<br><br>AAL-Profile instances can share buffer pools of the same buffer type(s)<br><br>The buffer type values are identified within the AAL-Profile specification.<br><br>An empty list indicates that the buffer(s) within the buffer pool(s) do not have an intended type of content that can be placed in the buffer pool(s). | +| buffer_size | N | integer | M | Indicates the buffer size for each requested buffer pool<br><br>NOTE: | + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-------------------|-------------|-----------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | <ul style="list-style-type: none"> <li>AAL Application shall indicate N buffer sizes, when requesting for creation of N buffer pool(s) (<math>N \geq 1</math>) in a single createBufferPool Operation</li> </ul> | +| number_of_buffers | N | integer | M | Indicates the size of each buffer pool, i.e., number of buffers available in each pool upon creation<br><br>NOTE: <ul style="list-style-type: none"> <li>AAL Application shall indicate N buffer pool sizes, when requesting for creation of N buffer pool(s), (<math>N \geq 1</math>) in a single createBufferPool Operation</li> </ul> | + +**Table 5.4.3.1-3: createBufferPool Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|--------------------------------------------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| status_of_operation | 1 | <i>Reference<br/>WG10<br/>object model</i> | M | Returns the status of the procedure. Indicates the status of createBufferPool Operation execution (TRUE for success, FALSE for failure)<br><br>If FALSE: Returns failure code if the AAL Implementation does not support pre-created buffer pools. | +| buffer_pool_handle | N | opaque handle | M | For each buffer pool, a handle to the pool<br><br>NOTE: Each buffer_pool_handle is associated with a specific buffer_size<br><br>A NULL shall be returned if the status_of_operation is FALSE (failure) | + +#### 5.4.3.2 allocBuffer + +Description: The allocBuffer operation shall support allocation of a buffer either from pre-created buffer pool(s), or from memory that is not associated with a pre-created buffer pool. + +Pre-conditions: If a non-NULL buffer\_pool\_handle is passed, the buffers are allocated from the buffer pool(s) created using the createBufferPool operation. + +Triggers: On demand request from the AAL Application + +Frequency: No restriction + +**Table 5.4.3.2-1: allocBuffer Operation** + +| Operation | Direction | +|-------------|---------------------------------------| +| allocBuffer | AAL Application => AAL Implementation | + +**Table 5.4.3.2-2: allocBuffer Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|--------------------|-------------|---------------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| buffer_pool_handle | 1 | opaque handle | M | A handle to a pre-created buffer pool generated using createBufferPool operation or a NULL handle. When a NULL handle is passed, the AAL Implementation shall not use memory that is part of a pre-created buffer pool. | +| message_size | 1 | integer | M | <p>Indicates message size (in bytes) for which the AAL Application is requesting buffer allocation</p> <p>NOTE:</p> <ul style="list-style-type: none"> <li>The AAL Application shall not use the allocated buffer for a message greater than the indicated message_size.</li> <li>Whether/how an AAL Implementation takes into consideration message_size in allocating the buffer is transparent to the AAL Application.</li> </ul> <p>When the value of the buffer_pool_handle is not NULL:</p> <ul style="list-style-type: none"> <li>The AAL Application shall request buffer allocation from a pre-created buffer pool with buffer_size <math>\geq</math> message_size > 0 <ul style="list-style-type: none"> <li>The AAL Application can indicate the message_size equal to the buffer_size associated with the buffer_pool_handle.</li> </ul> </li> <li>For optimal memory usage, AAL Application should indicate a buffer_pool_handle with associated buffer_size closest to the indicated memory size.</li> </ul> | + +**Table 5.4.3.2-3: allocBuffer Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|------------------------------------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| status_of_operation | 1 | <i>Reference WG10 object model</i> | M | <p>Returns the status of the procedure. Indicates the status of allocBuffer Operation execution (TRUE for success, FALSE for failure)</p> <p>NOTE: If the status of the operation is FALSE:</p> <ul style="list-style-type: none"> <li>Returns a failure code if the AAL Implementation requires buffers to be allocated from a pre-created buffer pool and the operation was invoked with buffer_pool_handle = NULL.</li> <li>Returns a failure code if the AAL Implementation does not support pre-created buffer pools and the operation was invoked with a buffer_pool_handle that is not NULL.</li> </ul> | + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|------------------|-------------|---------------|-----------|--------------------------------| +| | | | | | +| buffer_handle | 1 | opaque handle | M | Handle to the allocated buffer | + +#### 5.4.3.3 getBufferAddr + +Description: The getBufferAddr operation shall return address from buffer\_handle + +Pre-conditions: The buffer\_handle is created using allocBuffer operation + +Triggers: On demand request from the AAL Application + +Frequency: No restriction + +**Table 5.4.3.3-1: getBufferAddr Operation** + +| Operation | Direction | +|---------------|---------------------------------------| +| getBufferAddr | AAL Application => AAL Implementation | + +**Table 5.4.3.3-2: getBufferAddr Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|---------------|-----------|--------------------------------------------------------| +| buffer_handle | 1 | opaque handle | M | buffer object handle returned by allocBuffer operation | + +**Table 5.4.3.3-3: getBufferAddr Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|------------------------------------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------| +| status_of_operation | 1 | <i>Reference WG10 object model</i> | M | Returns the status of the procedure. | +| buffer_address | 1 | void * | M | Pointer that points to the starting virtual address of the buffer for the AAL Application to use. On error, buffer address will be NULL value. | + +#### 5.4.3.4 getBufferSize + +Description: The getBufferSize operation shall return the size of the buffer from buffer\_handle + +Pre-conditions: buffer\_handle is created using allocBuffer operation + +Triggers: On demand request from the AAL Application + +Frequency: No restriction + +**Table 5.4.3.4-1: getBufferSize Operation** + +| Operation | Direction | +|-----------|-----------| +|-----------|-----------| + +| | | +|---------------|---------------------------------------| +| getBufferSize | AAL Application => AAL Implementation | +|---------------|---------------------------------------| + +**Table 5.4.3.4-2: getBufferSize Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|---------------|-----------|--------------------------------------------------------| +| buffer_handle | 1 | opaque handle | M | buffer object handle returned by allocBuffer operation | + +**Table 5.4.3.4-3: getBufferSize Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|------------------------------------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------| +| status_of_operation | 1 | <i>Reference WG10 object model</i> | M | Returns the status of the procedure.<br><br>Indicates the status of <i>getBufferSize</i> operation execution (TRUE for success, FALSE for failure) | +| buffer_size | 1 | Integer | M | Size of the buffer | + +#### 5.4.3.5 sendBuffer + +Description: The sendBuffer operation shall support enqueueing of N buffer(s) ( $N \geq 1$ ) by the AAL Application. The AAL Application shall either retain buffer ownership in sendBuffer operation or indicate buffer ownership transfer. AAL Application shall indicate the synchronization mode ('synchronous' or 'asynchronous') in sendBuffer operation. + +AAL Implementation shall support both modes of operation. + +- For synchronous mode, the AAL Implementation, upon execution completion of sendBuffer operation, shall return the status of the sendBuffer operation +- For asynchronous mode, AAL Implementation shall return the status of sendBuffer operation execution, only if AAL Application preregisters for a callback; otherwise AAL Implementation is not expected to return the execution status of the sendBuffer operation + +FFS: Mechanism of sending details of AAL-Profile specific parameters + +Pre-conditions: Buffers are allocated through allocBuffer operation. At least one AAL-Profile-Instance is configured and started. At least one AAL-Profile-Queue is configured and started + +Triggers: On demand request from the AAL Application + +Frequency: No restriction + +**Table 5.4.3.5-1: sendBuffer Operation** + +| Operation | Direction | +|------------|---------------------------------------| +| sendBuffer | AAL Application => AAL Implementation | + +**Table 5.4.3.5-2: sendBuffer Input Parameter** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------------|-------------|---------------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| number_of_buffers | 1 | integer | M | Indicates number of enqueued buffer(s) ( $N \ge 1$ ) | +| per_buffer_config | N | structure | M | Structure containing attributes corresponding to enqueued buffer(s). | +| > buffer_handle | 1 | opaque handle | M | Indicates the buffer(s) containing metadata and payload to be sent. | +| > buffer_free | 1 | integer | M | When "TRUE" or 1, the AAL Application transfers ownership of the buffer to the AAL Implementation, which is expected to free the buffer upon completion of the sendBuffer operation, for each enqueued buffer.<br><br>When "FALSE" or 0, the AAL Application retains the ownership of the buffer and the AAL Implementation shall not automatically free the buffer upon completion of the sendBuffer operation. | +| aal_profile_instance_handle | 1 | opaque handle | M | Indicates the AAL-Profile-Instance corresponding to the buffer payload(s) | +| aal_queue_handle | 1 | opaque handle | M | Indicates the AAL-Profile-Queue associated with the enqueued buffer(s) | +| synchronization_mode | 1 | integer | M | Indicates synchronous/asynchronous mode of operation | + +**Table 5.4.3.5-3: sendBuffer Output Parameter** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|-------------------------------|-------------|------------------------------------|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| status_of_operation | 1 | <i>Reference WG10 object model</i> | M | Returns the status of the procedure.<br><br>Indicates the status of sendBuffer operation execution (success or failure) in synchronous mode and in asynchronous mode with preregistered callback<br><br>FFS: Details of callback preregistration mechanism | +| number_of_buffers_transmitted | 1 | integer | M | Indicates the total number of successfully transmitted buffers | +| status_of_each_buffer | N | bool | O | Optionally, returns status of each buffer (success or failure) | + +#### 5.4.3.6 receiveBuffer + +Description: The receiveBuffer operation shall support dequeuing up to N buffer(s) ( $N \geq 1$ ) by the AAL Application. The AAL Application shall indicate the synchronization mode ('synchronous' or 'asynchronous') in the receiveBuffer operation. + +AAL Implementation shall support both modes of the operation. + +- For synchronous mode, the AAL Implementation, upon execution completion of receiveBuffer operation, shall return the status of the receiveBuffer operation +- For asynchronous mode, the AAL Implementation shall return the status of receiveBuffer operation execution, only if AAL Application preregisters for a callback; otherwise AAL Implementation is not expected to return the execution status of the receiveBuffer operation + +Either the AAL Application, or the AAL Implementation shall allocate the receiving buffer(s) either from buffer pool(s) pre-created through createBufferPool operation or from memory not mapped to a pre-created buffer pool. + +Pre-conditions: At least one AAL-Profile-Instance is configured and started. At least one AAL-Profile-Queue is configured and started + +Triggers: On demand request from the AAL Application + +Frequency: No restriction + +**Table 5.4.3.6-1: receiveBuffer Operation** + +| Operation | Direction | +|---------------|---------------------------------------| +| receiveBuffer | AAL Application => AAL Implementation | + +**Table 5.4.3.6-2: receiveBuffer Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------------|-------------|---------------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| number_of_buffers | 1 | integer | M | Indicates maximum number of buffers ( $N \geq 1$ ) that can be dequeued by the AAL Application | +| buffer_handle | 0..N | opaque handle | M | Indicates dequeue buffer(s) allocated by the AAL Application.<br><br>If NULL, the AAL Implementation allocates the dequeue buffer(s) <ul style="list-style-type: none"> <li>The AAL Application shall not use the dequeue buffer(s) allocated by the AAL Implementation for any other subsequent send or receive operation</li> </ul> | +| aal_profile_instance_handle | 1 | opaque handle | M | Indicates the AAL-Profile-Instance corresponding to the dequeued buffer payloads | +| aal_queue_handle | 1 | opaque handle | M | Indicates the AAL-Profile-Queue associated with the dequeued buffers | + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|----------------------|-------------|-----------|-----------|------------------------------------------------------| +| synchronization_mode | 1 | integer | M | Indicates synchronous/asynchronous mode of operation | + +**Table 5.4.3.6-3: receiveBuffer Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|----------------------------|-------------|--------------------------------------------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| status_of_operation | 1 | <i>Reference<br/>WG10<br/>object model</i> | M | Returns the status of the procedure.<br><br>Indicates the status of receiveBuffer operation execution (success or failure) in synchronous mode and in asynchronous mode with preregistered callback<br><br>FFS: details of callback preregistration mechanism | +| number_of_received_buffers | 1 | integer | M | Indicates number of buffers (L) to be received by the AAL Application, which is < = maximum number of buffers (N) | +| buffer_handle | L | opaque handle | M | Indicates dequeue buffer(s) where from AAL Application retrieves the received data. | +| buffer_content_size | L | integer | O | Optionally, indicates the size (in bytes) of the contents of each received buffer | + +#### 5.4.3.7 freeBuffer + +Description: The freeBuffer operation shall free the buffer back to the buffer pool to which the buffer was allocated from. + +- If the buffer is not freed in the sendBuffer operation (i.e., buffer\_free parameter is set to 0 or 'FALSE'), the freeBuffer operation shall free the buffer upon completion of the sendBuffer operation execution by the AAL Implementation. + +Pre-conditions: The buffer\_handle is created using allocBuffer operation + +Post-condition: Upon successful completion of the freeBuffer operation, the buffer\_handle is no longer usable by the AAL Application + +Triggers: On demand request from the AAL Application + +Frequency: No restriction + +**Table 5.4.3.7-1: freeBuffer Operation** + +| Operation | Direction | +|------------|---------------------------------------| +| freeBuffer | AAL Application => AAL Implementation | + +**Table 5.4.3.7-2: freeBuffer Input Operation** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------|-------------|---------------|-----------|--------------------------------------------------------| +| buffer_handle | 1 | opaque handle | M | buffer object handle returned by allocBuffer operation | + +**Table 5.4.3.7-3: freeBuffer Output Operation** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|------------------------------------|-----------|------------------------------------------------------------------------------------------------------------------------------------------| +| status_of_operation | 1 | <i>Reference WG10 object model</i> | M | Returns the status of the procedure.<br><br>Indicates the status of freeBuffer Operation execution (TRUE for success, FALSE for failure) | + +#### 5.4.3.8 destroyBufferPool + +Description: The destroyBufferPool operation shall support termination of buffer pool, which will make buffer\_handle(s) associated with the buffer pool unusable by the AAL Application. + +Pre-condition: The buffer\_pool\_handle is created using createBufferPool operation + +Trigger: On demand request from the AAL Application + +Frequency: Infrequent + +**Table 5.4.3.8-1: destroyBufferPool Operation** + +| Operation | Direction | +|-------------------|---------------------------------------| +| destroyBufferPool | AAL Application => AAL Implementation | + +**Table 5.4.3.8-2: destroyBufferPool Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|--------------------|-------------|---------------|-----------|---------------------------------------------| +| buffer_pool_handle | 1 | opaque handle | M | Indicates handle to pre-created buffer pool | + +**Table 5.4.3.8-3: destroyBufferPool Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|------------------------------------|-----------|--------------------------------------------------------------------------------------------------------------------------------| +| status_of_operation | 1 | <i>Reference WG10 object model</i> | M | Returns the status of the procedure.<br><br>Indicates the status of destroyBufferPool Operation execution (success or failure) | + +### 5.4.4 AALI-C-App Administrative Operations + +#### 5.4.4.1 startAalProfileInstance + +Description: The AAL Application starts the AAL-Profile-Instance once it is ready to start operations. + +Pre-conditions: AAL-LPU is started, AAL Application is successfully configured, AAL-Profile-Instance is configured. The AAL-Profile-Instance is in the stopped state. + +On success, the AAL-Profile-Instance will be in the started state. + +Triggers: On demand request from the AAL Application. + +Frequency: Run time, infrequent. + +**Table 5.4.4.1-1: startAalProfileInstance Operation** + +| Operation | Direction | +|-------------------------|---------------------------------------| +| startAalProfileInstance | AAL Application => AAL Implementation | + +**Table 5.4.4.1-2: startAalProfileInstance Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------------|-------------|-----------|-----------|------------------------------------------------------| +| aal_profile_instance_handle | 1 | UUID | M | The identifier of the AAL-Profile-Instance to start. | + +**Table 5.4.4.1-3: startAalProfileInstance Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|-----------------------------|-----------|-------------------------------------| +| status_of_operation | | Reference WG10 object model | M | Returns the status of the procedure | + +#### 5.4.4.2 stopAalProfileInstance + +Description: The AAL Application stops the AAL-Profile-Instance. + +Pre-conditions: AAL-LPU is started, AAL Application is configured and started, the AAL-Profile-Instance is configured and started. + +On success, the AAL-Profile-Instance will be in the stopped state. + +Triggers: On demand request from the AAL Application. + +Frequency: Run time, infrequent. + +**Table 5.4.4.2-1: stopAalProfileInstance Operation** + +| Operation | Direction | +|------------------------|---------------------------------------| +| stopAalProfileInstance | AAL Application => AAL Implementation | + +**Table 5.4.4.2-2: stopAalProfileInstance Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|-----------------------------|-------------|-----------|-----------|-----------------------------------------------------| +| aal_profile_instance_handle | 1 | UUID | M | The identifier of the AAL-Profile-Instance to stop. | + +**Table 5.4.4.2-3: stopAalProfileInstance Output Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|--------------------------------------|-----------|-------------------------------------| +| status_of_operation | | Reference<br>WG10<br>object<br>model | M | Returns the status of the procedure | + +#### 5.4.4.3 startAalProfileQueue + +Description: The AAL Application starts the AAL-Profile-Queue once it is ready to start operations. + +Pre-conditions: AAL-LPU is started, AAL Application is successfully configured and started, AAL-Profile-Instance is configured and started, the AAL-Queue is configured and in stopped state. + +Triggers: On demand request from the AAL Application. + +Frequency: Run time. + +**Table 5.4.4.3-1 startAalprofileQueue Operation** + +| Operation | Direction | +|----------------------|---------------------------------------| +| startAalProfileQueue | AAL Application => AAL Implementation | + +**Table 5.4.4.3-2: startAalprofileQueue Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|--------------------------|-------------|-----------|-----------|-----------------------------------------------------------------| +| aal-profile-queue-handle | 1 | N/A | | The handle or identification of the AAL-Profile_Queue to start. | + +**Table 5.4.4.3-2: startAalprofileQueue Input Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|--------------------------------------|-----------|-------------------------------------| +| status_of_operation | | Reference<br>WG10<br>object<br>model | M | Returns the status of the procedure | + +#### 5.4.4.4 stopAalProfileQueue + +Description: The AAL Application stops the AAL-Profile\_Queue. + +Pre-conditions: AAL-LPU is started, AAL Application has successfully configured the AAL-Profile-Instance, AAL-Profile-Instance is configured and started, the AAL-Queue is configured and in started state. + +Triggers: On demand request from the AAL Application + +Frequency: Run time + +**Table 5.4.4.4-1 stopAalProfileQueue Operation** + +| Operation | Direction | +|---------------------|---------------------------------------| +| stopAalProfileQueue | AAL Application => AAL Implementation | + +**Table 5.4.4.4-2: stopAalProfileQueue Input Parameters** + +| Input Parameter | Cardinality | Data Type | Qualifier | Description | +|--------------------------|-------------|-----------|-----------|----------------------------------------------------------------| +| aal-profile-queue-handle | 1 | N/A | | The handle or identification of the AAL-Profile_Queue to stop. | + +**Table 5.4.4.4-2: stopAalprofileQueue Input Parameters** + +| Output Parameter | Cardinality | Data Type | Qualifier | Description | +|---------------------|-------------|-----------------------------|-----------|-------------------------------------| +| status_of_operation | | Reference WG10 object model | M | Returns the status of the procedure | + +# Annex A (normative): Acceleration Capability Requirements + +## A.1 Capability requirements used in the placement of an AAL Application to an AF + +Table A.1-1 contains a list of acceleration capability requirements that are common across AAL implementations. These capability requirements are used by the AAL Application to identify their requirements for use of AFs and by the SMO and/or DMS when assigning the AAL Application with a selected AF. + +**Table A.1-1: Acceleration Capability Requirements** + +| Capability requirement name | Data Type/Description | +|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| aalProfileRequirement | <b>Data Type:</b> AalProfileRequirement<br><b>Description:</b> The capability requirement for expressing what AAL-Profile is applicable when assigning an AAL-Profile to an AAL-LPU. | +| hwAcceleratorRequirement | <b>Data Type:</b> HwAccelRequirement<br><b>Description:</b> The capability requirement for expressing what HW Accelerator is applicable when assigning an AAL-Profile to an AAL-LPU. | +| aalLpuRequirement | <b>Data Type:</b> AalLpuRequirement<br><b>Description:</b> The capability requirements applicable when assigning an AAL-Profile to an AAL-LPU. | + +**Table A.1-2: Attributes for AalProfileRequirement** + +| Attribute name | Data Type/Description | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| name | <b>Data Type:</b> string<br><b>Description:</b> The name of the AAL-Profile as defined in the corresponding AAL-Profile specification. | +| supportedVersions | <b>Data Type:</b> Array of string<br><b>Description:</b> The versions of the AAL-Profile that the AAL Application can use. The version syntax is consistent with the version of the corresponding AAL-Profile specification. | +| preferredVersion | <b>Data Type:</b> string | + +| Attribute name | Data Type/Description | +|----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <b>Description:</b> The preferred version of the AAL-Profile that the AAL Application can use. The version syntax is consistent with the version of the corresponding AAL-Profile specification. | + +**Table A.1-3: Attributes for HwAccelRequirement** + +| Attribute name | Data Type/Description | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------| +| vendorName | <b>Data Type:</b> string<br><b>Description:</b> The HW Accelerator's vendor that is needed to support the AAL Application. | +| model | <b>Data Type:</b> string<br><b>Description:</b> The model of the HW Accelerator that is needed to support the AAL Application. | +| hwVersion | <b>Data Type:</b> string<br><b>Description:</b> hardware version of the HW Accelerator that is needed to support the AAL Application. | + +**Table A.1-4: Attributes for AalLpuRequirement** + +| Attribute name | Data Type/Description | +|----------------|------------------------------------------------------------------------------------------------------------------------------------------| +| aalIDriver | <b>Data Type:</b> string<br><b>Description:</b> The name of the AAL Implementation driver that is needed to support the AAL Application. | + +# Annex (informative): Change History + +| Date | Revision | Author | Description | +|-----------|----------|-----------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.2.28 | 00.00.01 | VMware, Ericsson, Wind River, Nvidia, Marvell, AT&T, Orange, Qualcomm | Initial skeleton | +| 2022.3.18 | 00.00.02 | VMware | Incorporated 2 CRs:<br><br>Management Objects Model CR (VMWare)<br><br>Common API Requirements CR (VMWare) | +| 2022.3.25 | 00.00.03 | NVIDIA, Intel, VMware | Incorporated 4 CRs:<br><br>Transport abstraction (NVIDIA)<br><br>AALI-C-App APIs (Intel)<br><br>AALI-C-Mgmt Workflow CR (VMWare)<br><br>AALI-C-Mgmt APIs CR (VMWare) | +| 2022.3.28 | 01.00 | Padma Sudarsan<br>VMware | Spec for final approval | +| 2022.5.12 | 01.00.01 | VMware | Incorporate CR:<br><br>Align AAL Definitions and Acronyms (Ericsson) | +| 2022.6.10 | 01.00.02 | Padma Sudarsan<br>VMware | Incorporate 7 CRs<br><br>AAL Transport Buffer Operations (Marvell)<br><br>AAL Transport API Operations (Nvidia)<br><br>AAL Transport Abstraction Requirements (Nvidia)<br><br>AAL-LPU start/Stop (Ericsson)<br><br>AAL Common API Spec Alignment (VMware)<br><br>AAL Get Accel Info part 1 (VMware)<br><br>AAL Common API e2e lcm flow (VMware et al.) | +| 2022.7.15 | 01.00.03 | Padma Sudarsan<br>VMware | Editor changes: | + +| | | | | +|------------|----------|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Modified cover page, footer, copyright, and Annex Z per new template</p> <p>Incorporate CRs:</p> <p>AAL Common API AAL Application Operations (Ericsson)</p> <p>Editor Changes:</p> <p>Modify Naming Conventions for Operations/parameters</p> <p>Identify sections that are still in progress</p> | +| 2022.7.20 | 01.00.04 | Padma Sudarsan<br>VMware | <p>Incorporate CRs:</p> <p>AAL Get Accel Info part 2 (VMware et al)</p> <p>AAL Common API e2e lcm flow enhancement (Intel, VMware.)</p> <p>AAL App Init Sequence alignment (VMware)</p> <p>Buffer Pool Create Operation (Nvidia et al)</p> <p>Buffer Send Operation (Nvidia et al)</p> <p>Buffer Receive buffer pool destroy operation (Nvidia et al)</p> <p>Editor Changes:</p> <p>Modify Naming Conventions for Operations/parameters etc.</p> | +| 2022.7.21 | 01.00.05 | Padma Sudarsan<br>VMware | <p>Incorporate CRs:</p> <p>AAL-C-Transport Call flow (Nvidia et al)</p> | +| 2022.7.25 | 01.00.06 | Padma Sudarsan<br>VMware | <p>Incorporate CRs:</p> <p>AAL-C-Transport Call flow (Nvidia et al) update</p> <p>Editorial Cleanup</p> | +| 2022.11.07 | 02.00.01 | Padma Sudarsan<br>VMware | <p>Incorporate CRs:</p> <p>AAL Transport API-freeBuffer clarification (Nvidia)</p> <p>Transport Req. alignment with receiveBuffer and freeBuffer (Nvidia)</p> <p>Transport receives buffer Operation clarification (Nvidia)</p> <p>e2e lcm flow updates (VMware)</p> <p>Correct UML in AALI-C-App API Init Sequence (Ericsson)</p> <p>Add Detailed API Diagrams (Intel, Nvidia)</p> <p>Update allocBuffer (Qualcomm)</p> <p>Update createBufferPool (Qualcomm)</p> | + +| | | | | +|------------|----------|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.11.07 | 02.00.02 | Padma Sudarsan<br>VMware | Editorial corrections based on comments from the member companies. | +| 2022.12.05 | 03.00.01 | Padma Sudarsan<br>VMware | Incorporate Editorial corrections.<br><br>Editorial alignment of terminology (Qualcomm)<br><br>Fault management service with AALI-C-Mgmt (Qualcomm, VMware, Ericsson) | +| 2023.1.11 | 03.00.02 | Padma Sudarsan<br>VMware | Incorporate Editorial corrections | +| 2023.2.1 | 03.00.03 | Padma Sudarsan<br>VMware | Incorporate CRs:<br><br>Common API Mgmt Requirement Clarification (Ericsson)<br><br>AAL-AALI-C-MGMT uploadBootImage Removal (Ericsson)<br><br>AAL-Common-API-03.00-Add-Inv-Sub-Not (Qualcomm) | +| 2023.3.11 | 03.00.04 | Padma Sudarsan<br>VMware | Incorporate CRs:<br><br>CR 0027 AAL Common API Updates from F2F (Qualcomm)<br><br>Incorporate Editorial corrections | +| 2023.3.17 | 03.00.05 | Padma Sudarsan<br>VMware | Incorporate Editorial corrections | +| 2023.4.18 | 04.00.01 | Padma Sudarsan<br>VMware | Incorporate Editorial corrections | +| 2023.6.20 | 04.00.02 | Padma Sudarsan<br>VMware | Incorporated the following CRs:<br><br>QCM: Update description in setAalAccelConfig and vendor specific attribute in set and get<br><br>INT: Fix missing AALI-C-App Init API<br><br>INT: AAL Common: Fix and update AALI-C-App State diagram<br><br>QCM: AAL Common: AAL IM Diagrams<br><br>QCM: AAL Common: AAL IM Management Definitions<br><br>QCM: AAL Common: AAL IM App Definitions<br><br>VMW: AAL Common: Changing Arch reference | +| 2023.6.28 | 04.00.03 | Padma Sudarsan<br>VMware | Incorporated the following CRs:<br><br>QCM: AAL Common Fix AAL IM Namespace | +| 2023.7.21 | 04.00.04 | Padma Sudarsan<br>VMware | Incorporated editorial comment | +| 2023.9.14 | 05.00.01 | Padma Sudarsan<br>VMware | Incorporated the following CRs: | + +| | | | | +|-----------|----------|-------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>NOK: Clarification on AALI-C-Mgmt Inventory Notification Parameters</p> <p>WNDR: AALI-C-Mgmt HAM registration</p> <p>Incorporate Editorial comments</p> | +| 2023.11.7 | 05.00.02 | <p>Padma Sudarsan</p> <p>VMware</p> | <p>Incorporate the following CRs.</p> <p>QCM: Remove reference to Alarm Dictionary</p> <p>QCM: Add HAM IM State</p> <p>QCM: AAL Common Add Capabilities</p> <p>QCM: Add HAM IM</p> <p>QCM: Fix DMS AAL Scenarios Requirement</p> <p>Incorporate Editorial comments.</p> | +| 2024-1-22 | 06.00.01 | <p>Padma Sudarsan</p> <p>VMware by Broadcom</p> | <p>Incorporate the following CRs:</p> <p>DCM-2023.10.24-WG6-commonAPI__CR001_scope_overview_v03</p> <p>QCM-2023.12.01-WG6-CR-0052-Common-API-Add-aalLpuConfig attribute to LPU</p> <p>QCM-2023.12.11-WG6-CR-0055-Common-API-Add-LPU-HW-Accel-Conditions</p> <p>QCM-2023.12.11-WG6-CR-0058-Common-API-Remove-PM-Dictionary</p> <p>QCM-2023.12.21-WG6-CR-0049-Common-API-Add-Capability-Advertisement</p> <p>QCM-2023.12.21-WG6-CR-0056-Common-API-Identify-Common-Requirements</p> <p>QCM-2023.11.30-WG6-CR-0051-Common-API-Remove_OCloud_Resource_Ref</p> | +| 2024-1-22 | 06.00.02 | <p>Padma Sudarsan</p> <p>VMware by Broadcom</p> | <p>Incorporate the following CRs:</p> <p>NOK-2023.10.11-WG6-CR0083-AAL-Common-HAM_IM v00.06</p> <p>DCM-2023.01.19-WG6-commonAPI__CR002_HAM_func_requirements_v06</p> <p>DCM-2023.10.24-WG6-commonAPI__CR003_c-mgmt requirements_v04</p> <p>NOK-2023.12.11-WG6-CR-AAL Common API Mgmt_requirement_v03</p> <p>DCM-2024.01.22-WG6-commonAPI__CR007_transport_abstraction framework_v1</p> <p>ERI-2024.1.18-WG6-CR-0044-AAL Common API UUID definition and reference_v3</p> | + +| | | | | +|-----------|----------|--------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | ERI-2024.1.23-WG6-CR-0045-AAL Common API URI reference and acronym_v4 | +| 2024-3-17 | 06.00.03 | Padma Sudarsan<br>VMware by Broadcom | DCM-2023.10.24-WG6-commonAPI__CR003_c-mgmt requirements_v05<br><br>ERI - 20240110-WG6-CR-0041-AAL Common-API - Removal of AALI-C-App requirements for interaction with DMS v04<br><br>ERI-2024.1.18-WG6-CR-0043-AAL Common API AAL resource identifier requirements_v7 | +| 2024-3-19 | 06.00.04 | Padma Sudarsan<br>VMware by Broadcom | Editorial updates | +| 2024-4-18 | 07.00.01 | Padma Sudarsan<br>VMware by Broadcom | Incorporate CR<br><br>ERI-2024.04.05-WG6-CR-0047-AAL Common API Re-add AALI-C-App Operations section accidentally removed in version 01.03 v2<br><br>Editorial changes | +| 2024-7-5 | 07.00.02 | Padma Sudarsan<br>VMware by Broadcom | Incorporate CR<br><br>NOK-2024.04.08-WG6-CR0112-AAL_CommonAPI-EditorialRemovalOfDuplicateText<br><br>QCM-2024.04.10-WG6-AAL-Common-CR-0063-Update-IM-Namespace<br><br>ERI-2024.04.05-WG6-CR-0048-AAL Common API Update ALI-C-App State Diagram v4 | + +# History + +| Date | Revision | Description | +|------------|----------|---------------------------------| +| 2022.03.28 | 01.00 | Published from version 00.00.03 | +| 2022.08.01 | 02.00 | Published from version 01.00.06 | +| 2022.11.21 | 03.00 | Published from version 02.00.02 | +| 2023.03.27 | 04.00 | Published from version 03.00.05 | +| 2023.07.31 | 05.00 | Published from version 04.00.04 | +| 2023.11.27 | 06.00 | Published from version 05.00.02 | +| 2024.4.10 | 07.00 | Published from version 06.00.04 | +| 2024.7.31 | 08.00 | Published from version 07.00.02 | \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/048c79215cc1eade95d9583a272a1757_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/048c79215cc1eade95d9583a272a1757_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fc1b3328494d7de1924b6f3d533fb87a62ee7925 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/048c79215cc1eade95d9583a272a1757_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ffc211b14371c06adf529c20eb49481719b3b6cf8cf27fbe9ba5afa41fb52bf4 +size 141547 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/062e061aa05f1e2d0b5af6dd7f786cbd_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/062e061aa05f1e2d0b5af6dd7f786cbd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9d38ce0e3aee8d85a05ce0717c5462b12367e4f4 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/062e061aa05f1e2d0b5af6dd7f786cbd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:708745da1ff00d273feb2a9fb11483943a1c90ef90125975bce881f0bf7a9a79 +size 34610 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/07139cef2d9a17d38eb1c4ef9300ae2a_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/07139cef2d9a17d38eb1c4ef9300ae2a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2e18e278b255de0963f08b8813d0c333a2c983d4 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/07139cef2d9a17d38eb1c4ef9300ae2a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b17906d693623be55549eae46bf3bfb0bbc54c8df000bea3fbf7bb92518b115d +size 138476 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/0e548a8600253c286b93223f864a8a42_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/0e548a8600253c286b93223f864a8a42_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1f3553d84e5619d13fcfe93dcc3293a27a3f4c27 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/0e548a8600253c286b93223f864a8a42_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d0435518c870a39cc3655810fd4954f3322ed2136428a8bb1317a4049145414e +size 52642 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/139e863e5c9070e81b5ded169a10bbf3_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/139e863e5c9070e81b5ded169a10bbf3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..048570b1f69c0b4182cbd1384a8bf6364685aa0a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/139e863e5c9070e81b5ded169a10bbf3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09de8ac0e17ec547aaff2372c0d3824a217e18e49944150e19e758ecbd0e4b09 +size 61600 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/153f104687072c1194f50ebe419bfff9_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/153f104687072c1194f50ebe419bfff9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8ec6a9e2a74d4f844f0c8626aff99e6193c07e1c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/153f104687072c1194f50ebe419bfff9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce20545b6abd5f2b7ddfc77ce460ba9695c9abbfaa29115f0e5edfc759808eb0 +size 38149 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/1cdd71e72c411d0a37b65ad55a12694c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/1cdd71e72c411d0a37b65ad55a12694c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..233f5ccd2a3025cb519b3109d5a68f73dd6d6cf8 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/1cdd71e72c411d0a37b65ad55a12694c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ccab19959e245a6c4264d0055081344212069e8ae02125b9bafa486c2b6d4dc5 +size 38805 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/1d4d26b60f5f4b2cd299137d518379ff_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/1d4d26b60f5f4b2cd299137d518379ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a0fc4c822f70f90cea062b77a8996a6d4155761c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/1d4d26b60f5f4b2cd299137d518379ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64e1750ba95b5a241fb756535224b0cd88eb8903143754478779ba49a04ef8ea +size 64338 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7b84e262d2fc7e0b59b4101053a42526958b946a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e7bdaaf5aacb655dae815886fc7e68b08115ae4458078ccf72b022c81a0a12c +size 4142 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/207760e01584b5d1d7b82a2d93666199_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/207760e01584b5d1d7b82a2d93666199_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..748f9be66555fd9310af0184c1f0f17b9bdac1f3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/207760e01584b5d1d7b82a2d93666199_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:04bddb23eaf3cad8be774e1945e136cca1943828b5e61932b45ab4a2e45c287a +size 20783 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2188319348af5a15a62689fa8b585c11_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2188319348af5a15a62689fa8b585c11_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6cf8b5894c75a5c4cacbfba4ffb0d0828e7064e8 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2188319348af5a15a62689fa8b585c11_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f0e0a024252f7124b458a9be964c175cd30d41e9f0ee2249b1985606772e61d5 +size 29170 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/23216cf856f906873749fe3da83094f9_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/23216cf856f906873749fe3da83094f9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9768827558595de617e18617708e2704703a6289 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/23216cf856f906873749fe3da83094f9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6cdd7de3f73b40aa6d7d1378db1fcae5de230174555b3473733325221e2a7598 +size 22141 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/23889e83eca2ca44e726e437ccdd694e_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/23889e83eca2ca44e726e437ccdd694e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b240ce21c99b4ddc7b5aa9c83805cbd9886093fb --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/23889e83eca2ca44e726e437ccdd694e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cb764ba1ddcb00aa76a5183a54c3d4a4c6cf5e5ab02afd3eed9cb7d10bbae289 +size 144179 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2403fd122a020f4cfa8685977be482ac_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2403fd122a020f4cfa8685977be482ac_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..77f201f2efdf9a9f5a7ac879050beaaf69a9d10b --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2403fd122a020f4cfa8685977be482ac_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a2ea531adf81312f355c67d70fd20336f82bd121bd1e5a12d7561e9bb24c0545 +size 3901 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2aeb5a9f8f876edd5be4252be81e4831_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2aeb5a9f8f876edd5be4252be81e4831_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0b98aae4e013af3a3a2bdc82be02f21af912e40a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2aeb5a9f8f876edd5be4252be81e4831_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cfd8199f967aca62c87b5d97dabba3ead717b52b95f1ceccadc8072fe5ec492d +size 145305 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2dc0ec8efd870a4610e147658a2eb972_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2dc0ec8efd870a4610e147658a2eb972_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9906a05002817c460be089770ef0070e1b107944 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/2dc0ec8efd870a4610e147658a2eb972_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b39836f07ee9b00f72f4265c72ee3b5db8605dae095c2a3a3914a154de143ae6 +size 148637 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/31b1c9b93e48a8f2cd30783b02d5f825_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/31b1c9b93e48a8f2cd30783b02d5f825_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cc47bce28e65bed85dd7f5366952a62cca0b0913 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/31b1c9b93e48a8f2cd30783b02d5f825_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2ce389ef305d4f7f0d72c849bca30318ff7758b7dc472e72459b2a538d7c3599 +size 28554 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/326f0dd17e7270c9eb44cc0d9d00c9ca_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/326f0dd17e7270c9eb44cc0d9d00c9ca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d4e288712f248b994761d4fb10e76073b507bec6 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/326f0dd17e7270c9eb44cc0d9d00c9ca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6fcf07316a04571d5ab584916e8374957160fc739fb4702013363bb67393fa2f +size 170103 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/468bc263d5fb57494881d4abafa4be24_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/468bc263d5fb57494881d4abafa4be24_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..88ba6e94369095c0c2c905f828035b2b189eca35 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/468bc263d5fb57494881d4abafa4be24_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f381e0e2031f637f15303305fb12ea49e1846c636c20441eac8891255aaf19eb +size 173601 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/4bdc37f4d404f4b668a7eef1562d6a2d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/4bdc37f4d404f4b668a7eef1562d6a2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..185aa1f78f184cddd203bea4de15309f108ad509 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/4bdc37f4d404f4b668a7eef1562d6a2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2f9ea499ee5e8a2d95b448eaa5ca06c94315d24593c052e46d2f4af9b192ba84 +size 34693 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/4e9bfdc0fc07d0c1201d20b7cc6a43b5_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/4e9bfdc0fc07d0c1201d20b7cc6a43b5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..09cbb1d35945831fef6374476a15bd22532ee72a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/4e9bfdc0fc07d0c1201d20b7cc6a43b5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e2ee04e0a90ec5dd3bc413594e02b53251dd0a3db80c3b70fb9beac2365a804d +size 4193 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/56a1854e45100e889160ee8cd359bd87_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/56a1854e45100e889160ee8cd359bd87_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9c72924165c787ae0b0f03e27ce8d9684827af70 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/56a1854e45100e889160ee8cd359bd87_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3f6a4e4eb38cded5843509e5ef023765ba51c34997505bbef90dbd40b1e7532d +size 145504 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/582ce4f3616814db4342b1caa3ca7089_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/582ce4f3616814db4342b1caa3ca7089_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ace943deaf887a8ab83d40927dfc3487bca63295 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/582ce4f3616814db4342b1caa3ca7089_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fb00cb324a4c1d803f813442e81bdc35214ba2a6b1632acc9e2aad820319f0fe +size 92474 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/5a8e870b255ae6f16a4fd2e3dddab3f2_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/5a8e870b255ae6f16a4fd2e3dddab3f2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..850975af18e644b06a8608236104989e0f3ccbdc --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/5a8e870b255ae6f16a4fd2e3dddab3f2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54b75b49f780f70aec031130d52c4bb7348626fb02e0e93e791d987c83182e11 +size 27735 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..44e4ca1e706fffc218594e75b7fbdfaeee43149d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ba36991bdae993881d357810ae680e8b2718eeb75c0831521a0cdc2d6e038f2 +size 4147 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/5f6cf62fce80e8d8307e047c91bff37a_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/5f6cf62fce80e8d8307e047c91bff37a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..857d85a9e6245ae55dc85e5bb804ddf7b1602900 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/5f6cf62fce80e8d8307e047c91bff37a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:65376e38c27aff8f27883612f6b115c0b01e87931b97306fe6349df7c31e72a9 +size 23172 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/6db1bebbff1b5e50f451ba5115c6167c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/6db1bebbff1b5e50f451ba5115c6167c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4eb24d35cb0015147ec8deff35736aff2e9ff1f7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/6db1bebbff1b5e50f451ba5115c6167c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9c65af54c4421dff97d8562bcc29a83dfb01e65ad633f3d08d6b154c7f54452 +size 4521 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/6fbff1efa94e5786eceb02cd60c69698_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/6fbff1efa94e5786eceb02cd60c69698_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bdb54d24fffae1e38e60eadc8b024e40881938ed --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/6fbff1efa94e5786eceb02cd60c69698_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:764f8a58f41ced5f01fda72d6d5e234f1424081f5dd7629b04e693c8f9af38ba +size 52486 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/71dd1f405065aa0bc414f99fcb02ce7d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/71dd1f405065aa0bc414f99fcb02ce7d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eb4a7fd758601c4eda53676e3764bc89a050b87c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/71dd1f405065aa0bc414f99fcb02ce7d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:85d6dda77734a034ad82212dbcc0428db0475266162460319f5e6a351878e38a +size 143812 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/75176d78f5c6b5ff3567815b4be47932_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/75176d78f5c6b5ff3567815b4be47932_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0841ccad53fa8bd2db834c2cda8fa6d21749f7c5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/75176d78f5c6b5ff3567815b4be47932_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:962f007f5de58610cd48be7f17f0761417fb483dea22790b8732253fe4ab77a6 +size 145336 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/76837c3cc481a9acdf914d02c7ea5973_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/76837c3cc481a9acdf914d02c7ea5973_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..36657875d075d6382b18678b0d60bee18918965a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/76837c3cc481a9acdf914d02c7ea5973_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dbeb242d7faf44bb9fae2428665b808cc1cc2af690e40db970a7a4ee323caa46 +size 144594 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/790746e3dcd66af9d66f695c9dec4534_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/790746e3dcd66af9d66f695c9dec4534_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0a2ceb0b6f6d03e4981c98d926c97087c0898c20 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/790746e3dcd66af9d66f695c9dec4534_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c07adc1c18eaf5357d9a13a014c630705ca00110a890c1355a9e009281ee94b9 +size 4040 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/7d2d6fadefd3e228af37ed9e22f71123_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/7d2d6fadefd3e228af37ed9e22f71123_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..18f22f4178ae30832e3381171bcd00820c6b0945 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/7d2d6fadefd3e228af37ed9e22f71123_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:298095c2cf7120b848a6921a3d6dde3b1050c915c2587a63bfabda1a59e1403c +size 138391 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/8311c3131ecc1a6432e91ac9d0a501ff_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/8311c3131ecc1a6432e91ac9d0a501ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de5968771dd51ef67235233003068f5ac1a99c6f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/8311c3131ecc1a6432e91ac9d0a501ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5adf021e489e4aa2cc4b1671e5d057eb158714ec6978a5071aba627a6582b5fe +size 141967 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/85ee300213fbdc8a49d75ea52141666d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/85ee300213fbdc8a49d75ea52141666d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dc6b48422f520494a35b42f62fdd4ffdbb4ddb96 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/85ee300213fbdc8a49d75ea52141666d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:890b29c88edd11aff1a5a92b1bfd39477cab9f87f7703de367fd58ce34cb2628 +size 45728 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/87f8fcf6b00e7e46e19fe0116e83d987_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/87f8fcf6b00e7e46e19fe0116e83d987_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2a50e330afff5c61e48e8cc5e5bb08a6b88e3cac --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/87f8fcf6b00e7e46e19fe0116e83d987_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aa8abdba83dc210afcaea23cca55366016311d5c1198b74986f5072bc9e3348f +size 85773 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9967fc65e43c0f351cc5279245b653cf_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9967fc65e43c0f351cc5279245b653cf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6ca389fbd972304f25dd3a50c1c74d0fe05954e2 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9967fc65e43c0f351cc5279245b653cf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e76ec7f2bc89b8c098c38a9bd1ddacc0c91fbfb4194532eb835597aa0acc5b2d +size 41235 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9b762b5fa2d457ee3aeb793a8c634341_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9b762b5fa2d457ee3aeb793a8c634341_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..037bd3565eb3c174282055055a6508bfc469f5f1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9b762b5fa2d457ee3aeb793a8c634341_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9eaab65198f0fcd395c5446e95f892f4e1e52dc9495b10d227d09049e9952df4 +size 135411 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9c313862e3c0b943015f24082015b23e_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9c313862e3c0b943015f24082015b23e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5d24384bf48fca62528d8f1750d10b91f6798098 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9c313862e3c0b943015f24082015b23e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:acdfc630d2f1d53698ddc8a5308ad435fcfd3eeefa4530ff52466aed84b9e465 +size 141852 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9e2ba5fca0d6a7198cd2c21fef5f469d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9e2ba5fca0d6a7198cd2c21fef5f469d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ea6c59b92dc99dce60c64c25f050413b8cd35e4d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/9e2ba5fca0d6a7198cd2c21fef5f469d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d70c567f3401ba4ed1fb2cf3c8cb4a8df92cdeb2021465498199b2f10fa50024 +size 142492 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/a2357d8f7ae4edb55383795158062371_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/a2357d8f7ae4edb55383795158062371_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2dfd5970c63a22d63457530531e0ea6e037489f4 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/a2357d8f7ae4edb55383795158062371_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:efb40eee8fffa343ced17d432bfcc7cea36e63cb2a5434fdfbf5a37635e71e0a +size 151471 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/a36f146fcedb5cba70205965a2ab4c99_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/a36f146fcedb5cba70205965a2ab4c99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbc4620842fa172a721feb28401cda5e06b0fd02 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/a36f146fcedb5cba70205965a2ab4c99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b33a8c8794b9d961c70bba3d67bc3e15f5e4c33951d9b62872346ab74b5cf41e +size 23032 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/a6ffb8c66aa91135e92c71767459313d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/a6ffb8c66aa91135e92c71767459313d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f36f5985370cd489a1b013191316f3013d692c9f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/a6ffb8c66aa91135e92c71767459313d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8b63f3db21abd7ee08def09bc27988d1dbb8b32dc28431ade9458d95e4b79be6 +size 55156 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/aada4b98ce0e528739e06c6c7f276f7d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/aada4b98ce0e528739e06c6c7f276f7d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6da8665280d4c5efe2bc7a5c1dab0f62362d44f2 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/aada4b98ce0e528739e06c6c7f276f7d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:459555e72d5e63f9aa93aefebd192117825b26331fb4aae6c8248d788d38d766 +size 21128 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/ab1dddf60f3dfcbf5e4ce39b0a85d110_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/ab1dddf60f3dfcbf5e4ce39b0a85d110_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c9bd83e169ae00aaa15ef8f5b6d1c66311d2c3de --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/ab1dddf60f3dfcbf5e4ce39b0a85d110_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:16f8cb5ca0ae3c9804ec02c5850ff9bcee0c309b8e8f1b149fb7096e9e2a1910 +size 106371 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/ab8b21bc2d581ba98f60635edf82390a_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/ab8b21bc2d581ba98f60635edf82390a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a710afe6c311cbaf2dacd50843a1259023ed2e24 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/ab8b21bc2d581ba98f60635edf82390a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b0b959480f25dc76ea1762cbf991d1d81759eae5137d3a7eda1821f66c95f388 +size 140827 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/b03fecb3a34cab8df3bea61affcc269b_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/b03fecb3a34cab8df3bea61affcc269b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..070625aaa6070fc1f07bf8096cb7c5f927aaec19 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/b03fecb3a34cab8df3bea61affcc269b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dfc8d2e8a3347073e04ead1ca6b0f7c235df1a93b9fb968b6fa88b294238ca0c +size 46878 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/b529be5a98bec46f65cbea35096d21b3_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/b529be5a98bec46f65cbea35096d21b3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..57a6780a487eca4beb53309d62e7c184afa3c673 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/b529be5a98bec46f65cbea35096d21b3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:abd2b768f606a09fc583a6e8e4636151231dd0910f2f50bf388764950c787b25 +size 34243 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c5ceeaba522967d2ca66967f4aa00a6f_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c5ceeaba522967d2ca66967f4aa00a6f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bb6d046ec328213d332078530f13d7dfe447e458 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c5ceeaba522967d2ca66967f4aa00a6f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:83a0233d98b11f57e5a6557bdbd7a3b84089ff7ac85a46a6026c5179d3970da7 +size 167040 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c625e8aa036cd7ab94572cb68c6e0e9e_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c625e8aa036cd7ab94572cb68c6e0e9e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4e3e7a375eb3f6b8612e70a140ebd0543958d126 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c625e8aa036cd7ab94572cb68c6e0e9e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2d8ef11ef148a84a4f8af81c1f0d23af730ee222c68f56aeb3514dba40052b28 +size 139328 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c6277da117aa05cd11899f48d3b70cb9_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c6277da117aa05cd11899f48d3b70cb9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5278650d61f515a551f275bc4dc058917bad648d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c6277da117aa05cd11899f48d3b70cb9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0d298b8a68cddf1775ffa9ff453eb589b28d7723a1bb91fe8f16cccf598f0ed4 +size 66958 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c8043b53aa69ceb98946fe935191c061_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c8043b53aa69ceb98946fe935191c061_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1b4355ce3740afd8e17ca217a56d60e96ebbd8e3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c8043b53aa69ceb98946fe935191c061_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f602dc58988e7c08ee57d77730e9466e4b6f7cfb70e1249cdd8b96c937ae4664 +size 146517 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c93a25365700ffd5046822a0ed48ee27_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c93a25365700ffd5046822a0ed48ee27_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..746c87354acb021cba7c2086e6f327977e07fdf7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c93a25365700ffd5046822a0ed48ee27_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cc7db7343b3d47ab7d3ab052cf92172aff776e0b1c9a97c72acab30950ee1108 +size 50179 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c9a80d1f8064f6a3e713285481816cf8_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c9a80d1f8064f6a3e713285481816cf8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..78272e7dd32adf61fe4bfe5ca9eaed4d2111fcbb --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/c9a80d1f8064f6a3e713285481816cf8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9e55bbb1b53443f994388e3368c71e15e43e468f79bf055bfa069fbcc34e5bea +size 145348 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/cbe2443cfd9d21a538e0b82d7095d7d4_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/cbe2443cfd9d21a538e0b82d7095d7d4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..35b628efa524d9907cc05f88022d35c17dca9a24 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/cbe2443cfd9d21a538e0b82d7095d7d4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fe8c4e2c20f6e067395a1ed1ab0ef4c45a47dc0e15ac161976d936a3a2365a69 +size 172952 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/cf236a91022cf9e5b8916dfd3ffc0568_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/cf236a91022cf9e5b8916dfd3ffc0568_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d05094f95f33d16ed1e8d211d4add86980355cb5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/cf236a91022cf9e5b8916dfd3ffc0568_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6e03d5b60daf69cfafeeeb9520d80fd660488dfd9f088be5550ffa5dac5ee289 +size 30376 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/da3e3e7121a832530eee4601dba49053_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/da3e3e7121a832530eee4601dba49053_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9534baadc5e51533f4210dbb69ad231076e27a42 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/da3e3e7121a832530eee4601dba49053_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd78c3d7de3475c9de0ad65d727887b4179a85e298304451ee1723bb1a36764f +size 35132 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/dc7e43fd179403deae0d9a1153aa8fa9_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/dc7e43fd179403deae0d9a1153aa8fa9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aedea7746c06caf9e6c7581d032da577e069d00d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/dc7e43fd179403deae0d9a1153aa8fa9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:38800520a5ef920d93d5f20a6012fc729d69a68a3dbdeae6daaba6dce2a1eaee +size 43885 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/e47aaa02ea47a0178b11996bb322f341_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/e47aaa02ea47a0178b11996bb322f341_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bf0df96590f5492ab4f9e58eb3a55296b1b4d44e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/e47aaa02ea47a0178b11996bb322f341_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3f84b19e1944b78be0647de033938eb7eaf9d441f9cc66feddf03a43f7457404 +size 38635 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/eb25fa4263b7f9f30eff7530604612a0_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/eb25fa4263b7f9f30eff7530604612a0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2a361cd6f5ab610f59a3061281966bade9d50b17 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/eb25fa4263b7f9f30eff7530604612a0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b64ba3ce431120c0e89a4479e63c5169d347dcb985986f981dd99f872ab6faf +size 11243 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/ee3986ed257817d27d2c122774861f5f_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/ee3986ed257817d27d2c122774861f5f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4a68e4a4f48675cb64cb20866721431bdfdeb248 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/ee3986ed257817d27d2c122774861f5f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6c7360e39856034900980bc33a470f4c07638bef8195a10d495f13c147e99c56 +size 166740 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/eed97810b73ce2008906a0918abed322_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/eed97810b73ce2008906a0918abed322_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e9d056186f91071754a1bd66cc5b0f58f9cdcd1d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/eed97810b73ce2008906a0918abed322_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a6feea577002af775f92c1c073ef8e278549447e23549760a568e59d2a4c42d6 +size 4142 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/f6067443347eac89ec6c099520a88d08_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/f6067443347eac89ec6c099520a88d08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bcbba17de884c24433163a582b470239f9f1a06c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/f6067443347eac89ec6c099520a88d08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f728d9a8ea144eeedb84cbd2dc6886dbd0053a801efb9034ebf286a09088aa9d +size 171584 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/f67fc9312059649b846b8901cb300e0c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/f67fc9312059649b846b8901cb300e0c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b9999fd6fdbe958fa4954661f74c747cd569214f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/f67fc9312059649b846b8901cb300e0c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4fc56521fc4faed76f0b6f343a92936716a487ad3e3fc2e94e0b8a026015f4dd +size 144853 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/f7b67189401efa9aec7b7b7c77b9fdf3_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/f7b67189401efa9aec7b7b7c77b9fdf3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6602990cbabc8926f48b9a5e985e5339ea93b430 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/f7b67189401efa9aec7b7b7c77b9fdf3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1bb02172f9a470ae98c7eeef969c42f4175de5aa974fe5da0cdb214acf09031e +size 61146 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/fa49186bb622c095765fd8ddc772729a_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/fa49186bb622c095765fd8ddc772729a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1af4baa9997cb759fd2b6a6708563bc34a058214 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/fa49186bb622c095765fd8ddc772729a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b7de6899a3e71e7d5cb96e3cf5688867518bde70faaa5a1d8d15817d1aa6097 +size 4042 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/raw.md b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..8390d3ee90fbbe59e110319dbb301027f4f7bd89 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00/raw.md @@ -0,0 +1,2362 @@ + + +1 + +2 + +# **O-RAN Working Group 6 (Cloudification and Orchestration Work Group)** + +# **O-RAN Acceleration Abstraction Layer General Aspects and Principles** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + + + +| | | | | +|----|----------------------|------------------------------------------------------------------------------------|----| +| 1 | 6.2.5 | AAL Profile(s) offload, processing status query and processed data retrieval ..... | 35 | +| 2 | 6.2.6 | AAL-LPU Exposure ..... | 35 | +| 3 | 7. | AAL Profiles ..... | 38 | +| 4 | 7.1 | O-DU AAL Profiles ..... | 38 | +| 5 | 7.1.1 | O-DU Protocol Stack Reference..... | 38 | +| 6 | 7.1.2 | O-DU Protocol Stack Reference for mMTC ..... | 42 | +| 7 | 7.1.3 | O-DU AAL Profile Definitions ..... | 46 | +| 8 | 7.2 | O-CU AAL Profiles ..... | 69 | +| 9 | Annex (informative): | Change History..... | 70 | +| 10 | | | | + +11 + +## List of Figures + +| | | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------|----| +| Figure 4.1-1: Example illustration of the effect of hardware acceleration on functional compute performance. .... | 12 | +| Figure 4.2.2-1: High Level AAL Architecture Diagram..... | 14 | +| Figure 4.2.2-2: AAL Resource Relationship and Cardinality ..... | 15 | +| Figure 4.2.3-1 Example HAM software deployment scenarios ..... | 16 | +| Figure 4.2.4-1: AAL Application Common and profile APIs..... | 17 | +| Figure 4.2.5-1: Accelerator APIs/Libraries in Container (left) and Virtual Machine Implementations (right)..... | 18 | +| Figure 4.2.5.1-1: Example AAL Implementation Software deployment contained within O-Cloud Platform Software only..... | 19 | +| Figure 4.2.5.1-2: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and NF Deployment..... | 19 | +| Figure 4.2.5.1-3: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and NF Deployment in a virtual machine environment..... | 20 | +| Figure 5.1.5-1: Logical Representation of AAL Application interface support for multiple AAL-LPUs..... | 23 | +| Figure 5.1.7-1: AAL Application interface look-aside acceleration model - Data flow..... | 23 | +| Figure 5.1.8-1: AAL Application interface inline acceleration model - Data flow ..... | 24 | +| Figure 5.1.8-2: User plane dataflow paths in look-aside and inline acceleration architectures. .... | 25 | +| Figure 5.1.14-1: Data flow through unchained AAL Profiles..... | 26 | +| Figure 5.1.14-2: Data flow through chained AAL Profiles..... | 27 | +| Figure 5.1.14-3: Dataflow through chained lookaside HW Accelerator for consecutive Hi-PHY functions..... | 28 | +| Figure 5.1.14-4: Dataflow through chained lookaside HW Accelerator for consecutive and non-consecutive PHY..... | 28 | +| Figure 5.2.4-1: Partial Inline Model for AAL Hi-PHY Profile..... | 29 | +| Figure 6.2.1-1: Scenario 1: A single AAL LPU exposes a single AAL Profile Queue used by a single AAL Application. .... | 31 | +| Figure 6.2.1-2: A single HW Accelerator supporting two LPU's each assigned to individual AAL Applications ..... | 32 | +| Figure 6.2.1-3: Two HW Accelerators each supporting a single AAL-LPU assigned to a single AAL Application..... | 32 | +| Figure 6.2.1-4: A single AAL LPU exposes two AAL Profile Queues used by a single AAL Application. .... | 33 | +| Figure 6.2.1-5: A single AAL LPU supporting two AAL Profile Instances exposes two AAL Profile Queues used by a single AAL Application. .... | 33 | +| Figure 6.2.1-6: AAL-LPU Mapping example showing chained profile support ..... | 34 | +| Figure 6.2.6.2.1-1: Example AAL-LPU and profile supported ..... | 35 | +| Figure 6.2.6.2.1-2: Example HW Accelerator configuration ..... | 36 | +| Figure 6.2.6.2.1-3: Example assignment of AAL-LPUs and supported profiles to POD..... | 36 | +| Figure 6.2.6.2.2-1: Example AAL Application configured AAL-Profile-Instances..... | 37 | +| Figure 7.1.1-1: O-DU PHY processing blocks for 5G NR Downlink ..... | 38 | +| Figure 7.1.1-2: O-DU PHY processing blocks for 5G NR Uplink ..... | 40 | +| Figure 7.1.2-1: O-DU PHY processing blocks for mMTC Downlink..... | 43 | +| Figure 7.1.2-2: O-DU PHY processing blocks for mMTC Uplink..... | 45 | +| Figure 7.1.3.2.1-1: AAL_MU-MIMO_PRECODER_WEIGHTS_CALC ..... | 47 | +| Figure 7.1.3.2.1-2: Example AAL_MU-MIMO_PRECODER_WEIGHTS_CALC use..... | 47 | +| Figure 7.1.3.2.2-1: AAL_FFT ..... | 48 | +| Figure 7.1.3.2.2-2: AAL_FFT example for SRS Processing ..... | 49 | +| Figure 7.1.3.3.1-1: AAL_PDSCH_FEC Profile..... | 50 | +| Figure 7.1.3.3.2-1: AAL_PDSCH_HIGH-PHY Profile..... | 51 | +| Figure 7.1.3.3.3-1: AAL_PDCCH_HIGH-PHY Profile ..... | 52 | +| Figure 7.1.3.3.4-1: AAL_PBCH_HIGH-PHY Profile ..... | 53 | +| Figure 7.1.3.3.5-1: AAL_CSI-RS_HIGH-PHY Profile ..... | 54 | +| Figure 7.1.3.3.6-1: AAL_PT-RS-DL_HIGH-PHY Profile ..... | 55 | +| Figure 7.1.3.3.7-1 AAL_DOWNLINK_HIGH-PHY Profile..... | 56 | +| Figure 7.1.3.4.1-1: AAL_PUSCH_FEC Profile..... | 57 | +| Figure 7.1.3.4.2-1 : AAL_PUSCH_HIGH-PHY Profile..... | 58 | +| Figure 7.1.3.4.3.1-1: AAL_PUCCH_HIGH-PHY Profile (PUCCH format 0) ..... | 59 | +| Figure 7.1.3.4.3.2-1: AAL_PUCCH_HIGH-PHY Profile (PUCCH format 1) ..... | 60 | +| Figure 7.1.3.4.3.3-1: AAL_PUCCH_HIGH-PHY Profile (PUCCH format 2/3/4) ..... | 61 | +| Figure 7.1.3.4.4-1: AAL_PRACH_HIGH-PHY Profile ..... | 62 | +| Figure 7.1.3.4.5-1: AAL_SRS_HIGH-PHY Profile ..... | 63 | +| Figure 7.1.3.4.6-1: AAL_PT-RS-UL_HIGH-PHY profile ..... | 64 | +| Figure 7.1.3.4.7-1: AAL_UPLINK_HIGH-PHY Profile..... | 65 | + +| | | | +|---|--------------------------------------------------|----| +| 1 | Figure 7.1.3.5.1-1: AAL_NPDSCH_FEC Profile..... | 66 | +| 2 | Figure 7.1.3.5.2-1: AAL_NPDCCH_FEC Profile ..... | 67 | +| 3 | Figure 7.1.3.5.3-1: AAL_NPBCH_FEC Profile ..... | 68 | +| 4 | Figure 7.1.3.5.4-1: AAL_NPUSCH_FEC Profile..... | 69 | +| 5 | | | + +# 6 Foreword + +7 This Technical Specification (TS) has been produced by W6 of the O-RAN Alliance. + +8 The content of the present document is subject to continuing work within O-RAN and may change following formal O- +9 RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O- +10 RAN with an identifying change of version date and an increase in version number as follows: + +11 version xx.yy.zz + +12 where: + +13 xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, +14 updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +15 yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. +16 Always 2 digits with leading zero if needed. + +17 zz: the third digit-group included only in working versions of the document indicating incremental changes during +18 the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if +19 needed. + +###### 20 Modal verbs terminology + +21 In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and +22 "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression +23 of provisions). + +24 "**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +25 + +# --- 1. Scope + +This document defines O-RAN O-Cloud hardware accelerator interface functions and protocols for the O-RAN AAL interface. The document studies the functions conveyed over the interface, including configuration and management functions, procedures, operations and corresponding solutions, and identifies existing standards and industry work that can serve as a basis for O-RAN work. + +# 2. References + +## 2.1 Normative References + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN WG1 Architecture Description +- [2] O-RAN WG1 OAM Architecture +- [3] Void +- [4] ETSI GS NFV-IFA 002: "Network Functions Virtualization (NFV) Release 2; Acceleration Technologies; VNF Interfaces Specification" +- [5] [ETSI GS NFV-IFA 019: "Network Function Virtualization \(NFV\); Acceleration Technologies; Acceleration Resource Management Interface Specification; Release 3"](#) +- [6] [5G; NR; Physical Channels and Modulation 3GPP TS 38.211 v15.2.0 Release 15](#) +- [7] [5G; NR; Multiplexing and Channel Coding 3GPP TS 38.212 v15.2.0 Release 15](#) +- [8] [LTE; E-UTRA Physical Channels and Modulation 3GPP TS 36.211 v15.2.0 Release 15](#) +- [9] [LTE; E-UTRA Multiplexing and Channel Coding 3GPP TS 36.212 v15.2.1 Release 15](#) +- [10] ETSI GS [NFV-IFA 001](#): "Network Functions Virtualisation (NFV); Acceleration Technologies; Report on Acceleration Technologies & Use Cases" +- [11] O-RAN WG6 O2 General Aspects and Principles +- [12] O-RAN WG6 Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN +- [13] ETSI GS NFV-IFA [011](#): "Network Functions Virtualisation (NFV) Release 4; Management and Orchestration; VNF Descriptor and Packaging Specification" +- [14] ETSI GR NFV-IFA 046: "Network Functions Virtualisation (NFV) Release 5; Architectural Framework; Report on NFV support for virtualisation of RAN" +- [15] O-RAN WG6 AAL Common API R003 +- [16] O-RAN WG4 Control, User and Synchronization (CUS) Plane Specification + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- 1 [i.1] [Vocabulary for 3GPP Specifications \(TR21.905\)](#) +- 2 +- 3 + +# 3. Definitions of terms, symbols and abbreviations + +## 3.1 Terms + +For the purpose of this document the terms and definitions given in O-RAN WG6 Cloudification and Orchestration Use Cases (UC) and Requirements for O-RAN Virtualized RAN [13], ETSI GS NFV-IFA 002 [4], and the following apply: + +**Hardware (HW) Accelerator (HWA)** is a specialized HW implementation that can offload processing from application(s) running on a General-Purpose Processor. The Hardware (HW) Accelerator is a physical Managed Element as defined in [13]. + +NOTE: Examples of Hardware Accelerators include ASIC, FPGA, DSP and GPU. + +NOTE: Throughout this document, the term “Accelerator” and “Hardware (HW) accelerator” are used interchangeably. + +**Acceleration Abstraction Layer (AAL)** specifies a common and consistent set of interfaces used by different entities to enable interaction with different types of HW Accelerators within an O-Cloud instance. + +**AAL Implementation** is a realization of an AAL including but not limited to the software libraries, drivers and the Hardware Accelerator + +**Accelerated Function (AF)** is a representation of a workload building block that an accelerator processes on behalf of an AAL Application within an O-RAN Network Function in an O-Cloud [1]. + +**AAL Application (AAL-App)** is defined as a workload that can offload Accelerated Functions to AAL-LPU(s). + +NOTE: Unless explicitly noted, the term Application refers to an AAL Application in AAL specifications. + +NOTE: Unless explicitly noted, the terms Application, NF Application, L2 Application, VNF/CNF, or NF workload accessing the AAL in figures of this present document refers to an AAL Application. + +**AAL Profile(s) (AAL-Profile)** specify one or more Accelerated Functions that an accelerator processes on behalf of an AAL Application within an O-RAN Network Function in an O-Cloud [1]. + +**AAL Operations** actions supported by the AAL interface. + +**AAL Profile Instance (AAL-Profile-Instance)** is an executing instance of an AAL profile that can be used by an AAL Application via the AAL interface. The AAL-Profile-Instance executes within an AAL-LPU execution environment. + +**AAL Logical Processing Unit (AAL-LPU)** is a logical representation of resources within an instance of a HW Accelerator (example: there can be multiple processing units or subsystems on a hardware accelerator, or resource partitioning (hard – dedicated resources, soft – soft resources) and these can be logically represented as a AAL Logical Processing Unit) + +**AAL Profile Queue** is a logical grouping construct and may be used by the AAL Application to group operations together. For example, AAL Profile Queues may access specific resources (compute, I/O) of an AAL-LPU executing specific AAL Profile Instances(s). + +**AAL Profile Queue ID** is a unique index used to designate the AAL Profile Queue in function exposed by specific AAL profile. + +NOTE: An AAL Profile Queue or an AAL Profile Queue ID does not reflect a HW design or an AAL Implementation specification + +**HW Accelerator Manager (HAM)** is an acceleration management function, that provides management capabilities for the HW Accelerator(s) and the AAL-LPU's in the O-Cloud Node. Management capabilities include but not limited to lifecycle management, configuration, updates/upgrades and failure handling of the HWA and the LPUs. The HAM may use the services of an external software repository to securely transfer approved software artifacts, for example FW/SW images, binaries, libraries and configuration data. The specification of a software repository and the communication with the HAM are outside the scope of O-RAN specifications. The HW Accelerator Manager is considered an O-Cloud Platform Software. + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in [i.1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in [i.1]. + +| | | +|-------------|-----------------------------------------------------------------| +| AF | Accelerated Function | +| AAL | Acceleration Abstraction Layer | +| AAL-App | Acceleration Abstraction Layer - Application | +| AAL-LPU | Acceleration Abstraction Layer - LPU | +| AALI-C | Acceleration Abstraction Layer Interface-Common | +| AALI-C-Mgmt | Acceleration Abstraction Layer Interface-Common-Management | +| AALI-C-App | Acceleration Abstraction Layer Interface-Common-Application | +| AALI-P | Acceleration Abstraction Layer Interface-Profile | +| BF | Beam-forming | +| CNF | Cloudified Network Function | +| DFT/iDFT | Discrete Fourier Transform / Inverse Discrete Fourier Transform | +| DMS | Deployment Management Services | +| FCAPS | Fault, Configuration, Accounting, Performance, Security | +| FEC | Forward Error Correction | +| FFT/iFFT | Fast Fourier Transform / inverse Fast Fourier Transform | +| HWA | Hardware Accelerator | +| IMS | Infrastructure Management Services | +| LPU | Logical Processing Unit | +| RB | Resource Block | +| SMO | Service Management and Orchestration | +| UC | Use Case | +| VNF | Virtual Network Function | + +# --- 4. General Aspects + +## 4.1 Hardware Acceleration + +In the design of digital computing systems, ranging from general-purpose processors to fully customized hardware, there is a tradeoff between flexibility and efficiency, with efficiency increasing by orders of magnitude when any given application is implemented in hardware. The range of implementation options includes general-purpose processors (GPPs) such as CPUs, more specialized processors such as Graphics Processing Units (GPUs), functions implemented on field-programmable gate arrays (FPGAs), and fixed-functions implemented on application-specific integrated circuits (ASICs). Hardware accelerator is a specialized HW implementation that can offload processing from application(s) running on the General-Purpose Processor (GPP). Any transformation of data or computation can be implemented purely in software running on a generic CPU, or purely in a specialized hardware accelerator, or using a combination of both. The implementation of computing tasks in hardware to improve performance is known as hardware acceleration. The hardware acceleration can be implemented in the form of lookaside or inline mode where in the former case, the host CPU invokes an accelerator for data processing and receives the result after processing is complete, while in the latter case, the accelerator, after being invoked by the host CPU with the request for data processing, completes the processing request of data received from a source node and directly transfers the post-processed data to a destination node, where the source or destination node can be different than host CPU (e.g., an Ethernet Interface). The principle of hardware acceleration and functional offloading in lookaside mode and inline is illustrated in Figure 4.1-1, allowing the application to offload workload to a hardware accelerator and to continue performing other work in parallel- this could be to continue to execute other software tasks in parallel or to sleep and wait for the accelerator hardware to complete. The hardware acceleration boosts application performance in environments with compute-intensive, deeply pipelined, massively parallel operations as shown in Figure 4.1-1. This model requires the support of two operations, one for initiating the offload and another for retrieving the operation once complete. + +### Without hardware acceleration – serial execution + +![Diagram showing serial execution of five functions (Func 1 to Func 5) on a CPU. The functions are connected in a linear sequence: CPU -> Func 1 -> Func 2 -> Func 3 -> Func 4 -> Func 5 ->.](eb25fa4263b7f9f30eff7530604612a0_img.jpg) + +Diagram showing serial execution of five functions (Func 1 to Func 5) on a CPU. The functions are connected in a linear sequence: CPU -> Func 1 -> Func 2 -> Func 3 -> Func 4 -> Func 5 ->. + +### With hardware acceleration – massively parallel execution within and across functions + +#### Lookaside + +![Diagram showing lookaside hardware acceleration. The CPU handles Func 1 and Func 5. The Accelerator handles Func 2, Func 3, and Func 4. Arrows show data flow from Func 1 to Func 2, 3, and 4, and from Func 3, 4, and 5 to the next stage.](5f6cf62fce80e8d8307e047c91bff37a_img.jpg) + +Diagram showing lookaside hardware acceleration. The CPU handles Func 1 and Func 5. The Accelerator handles Func 2, Func 3, and Func 4. Arrows show data flow from Func 1 to Func 2, 3, and 4, and from Func 3, 4, and 5 to the next stage. + +Accelerator handles compute-intensive, deeply pipelined, massively parallel operations. The CPU handles other operations + +#### Inline + +![Diagram showing inline hardware acceleration. The CPU handles Func 1. The Accelerator handles Func 2, Func 3, and Func 4. Func 5 is also handled by the Accelerator. Arrows show data flow from Func 1 to Func 2, 3, and 4, and from Func 4 to Func 5.](a36f146fcedb5cba70205965a2ab4c99_img.jpg) + +Diagram showing inline hardware acceleration. The CPU handles Func 1. The Accelerator handles Func 2, Func 3, and Func 4. Func 5 is also handled by the Accelerator. Arrows show data flow from Func 1 to Func 2, 3, and 4, and from Func 4 to Func 5. + +**Figure 4.1-1: Example illustration of the effect of hardware acceleration on functional compute performance.** + +## 4.2 AAL Architecture and concepts + +### 4.2.1 Overview + +The goal of the acceleration abstraction layer (AAL) is to specify a common and consistent set of interfaces to enable interactions with the HW Accelerators and facilitates decoupling of an AAL Application, from a specific HW implementation. To accommodate the many different combinations of HW and SW implementation and many different network deployment scenarios, the AAL introduces the concept of an AAL profile which is used to distinguish between the different combinations of accelerated functions to be offloaded. + +The AAL specifications shall define the AAL interface between the AAL Application and AAL Implementation in the O-Cloud instance. This includes the APIs, information models, operations and input/outputs used by the AAL Application to interface with the AAL Implementation. When the AAL APIs are utilized: + +- AAL Applications that utilize the AAL APIs render the same functionality as described in the O-RAN specifications describing the AAL Application [1]. +- AAL Applications that utilize the AAL APIs shall preserve the interface definitions and behave the same way as described in the O-RAN specifications describing those interfaces. +- O-RAN NFs that utilize the AAL APIs shall preserve the synchronization topologies as defined in [16]. + +In addition, the AAL Specification shall define the requirements for managing the hardware accelerator in the O-Cloud instance. The AAL Implementation itself shall not be defined by the AAL GAnP specification. ETSI GS NFV-IFA 002 [5] defines several abstraction models including pass through and abstracted models that can be used to realize an AAL Implementation. + +The AAL specification facilitates the following: + +An O-cloud provides the flexibility of deploying multiple software implementations from different software vendors on a common CPU-based (e.g., x86/ARM) platform with hardware accelerators (e.g., FPGA/DSP/ASIC/GPU) for specific functions, and conversely, also allows multiple physical deployment scenarios in terms of centralizing or distributing each network element with the same software implementation. + +A disaggregated and cloudified multi-vendor RAN requires common vendor-neutral APIs for managed element discovery, lifecycle management, FM/PM, and orchestration across both PNFs and VNFs in order to function as a cohesive unit that supports key lifecycle use cases such as scale-out, slice management, fault tolerance, and hitless software upgrades. + +### 4.2.2 AAL Architecture + +The end-to-end high-level AAL architecture block diagram is shown in Figure 4.2.5.1-1. For AAL Applications O1 interface usage is optional. Interaction between DMS and AAL Application is out of the scope of this document. For further understanding of the deployment and operation of AAL-LPUs please refer to section 6.2. + +![High Level AAL Architecture Diagram showing the interaction between SMO, IMS, DMS, AAL Applications, AAL Implementation, and HW Accelerator Manager.](f67fc9312059649b846b8901cb300e0c_img.jpg) + +The diagram illustrates the High Level AAL Architecture. At the top, the **Service Management and Orchestration (SMO)** block contains **Federated O-Cloud Orchestration and Management**, **Network Function Orchestrator (NFO)**, and **RAN Network Function FCAPS**. A cloud icon labeled "Planning, Manifest, artifacts etc.." points to the SMO. Below SMO, the **IMS** and **DMS** blocks are connected by a "Vendor Specific" interface. SMO connects to IMS via **O2ims** and to DMS via **O2dms**. A **Common administrative operations/actions/events from the HW Accelerator Manager toward the O-Cloud IMS** box points to the AAL-C-Mgmt interface between IMS and the HW Accelerator Manager. The **HW Accelerator Manager** (teal box) connects to the **AAL Implementation** block via a "Vendor Specific" interface. The AAL Implementation block is part of an **O-Cloud Compute Node** and contains multiple **AAL Applications** (AAL Application, AAL Application, ..., AAL Application). These applications interact with **AAL-C-App** and **AAL-P** interfaces. Below the applications is the **AAL Implementation** section, which includes **AAL Profile Queues** and **AAL Profile Instances** (AAL Profile Instance, AAL Profile Instance, ..., AAL Profile Instance) running on **AAL-LPU 0**, **AAL-LPU 1**, ..., **AAL-LPU N**. These LPUs are part of the **HW Accelerator (Physical)**. A **Common operations/actions/events toward AAL Application** box points to the AAL Applications. A **AAL-Profile Specific API that provides control of an instance of AAL-Profile** box points to the AAL Profile Instances. A dashed box around the AAL Implementation section is labeled "Leverage Open source and existing K8s, ETSI-NFV etc..". A legend at the bottom indicates: a double-headed black arrow for "In scope for WG6 AAL Subgroup", a double-headed red arrow for "Standardized by WG6 O2 Subgroup", and a dashed double-headed arrow for "Vendor Specific". + +High Level AAL Architecture Diagram showing the interaction between SMO, IMS, DMS, AAL Applications, AAL Implementation, and HW Accelerator Manager. + +**Figure 4.2.2-1: High Level AAL Architecture Diagram** + +Figure 4.2.2-2: shows a pictorial view of the entity relationship and cardinality between AAL entities that constitute the AAL architecture. It is not meant to be the basis of a class diagram or object model which would normally be the start of an information model. Its purpose is just to help the reader mentally conceptualize the concepts depicted. See clause 4.2.4 of the present document for a high-level description of the AAL-C-Mgmt interface and the AAL-C-App interface. See [15] for a detailed description of the specification of the AAL-C-Mgmt and AAL-C-App interfaces and the operations supported. + +AAL Managed Elements and Managed Functions are managed by SMO via the O2 interface exposed by the IMS and DMS using the AALI-C-MGMT interface terminated by the HW Accelerator Manager. Specifically, AAL Managed Elements and Managed Functions do not utilize the O1 interface for management of AAL Managed Elements and Managed Functions. + +The HW Accelerator, the HW Accelerator Manager, AAL-LPU and AAL drivers are defined as O-Cloud Platform Software for the purposes of management and orchestration [1]. The O-Cloud Infrastructure and O-Cloud Platform Software use case flows in [12] are applicable for these AAL elements. + +![Figure 4.2.2-2: AAL Resource Relationship and Cardinality. This UML class diagram illustrates the relationships between various AAL components. The components are: IMS, HW Accelerator Manager, Hardware Accelerator, Accelerated Function, AAL Logical Processing Unit, AAL Profile, AAL Application, AAL Profile Instance, and AAL Profile Queue. Relationships include: IMS (1) manages (0..n) HW Accelerator Manager; HW Accelerator Manager (1) manages (0..n) Hardware Accelerator; Hardware Accelerator (1) resources rep by (0..n) AAL Logical Processing Unit; Accelerated Function (1..n) specifies (1..n) AAL Profile; AAL Logical Processing Unit (1..n) supports (0..n) AAL Profile; AAL Logical Processing Unit (1) uses (0..n) AAL Application; AAL Application (1) uses (0..n) AAL Profile Instance; AAL Profile (0..n) is realized by (0..n) AAL Profile Instance; AAL Profile Instance (1) consists of (0..n) AAL Profile Queue; and AAL Application (1) uses (0..n) AAL Profile Queue.](85ee300213fbdc8a49d75ea52141666d_img.jpg) + +``` + +classDiagram + class IMS + class HW_Accelerator_Manager["HW Accelerator Manager"] + class Hardware_Accelerator["Hardware Accelerator"] + class Accelerated_Function["Accelerated Function"] + class AAL_Logical_Processing_Unit["AAL Logical Processing Unit"] + class AAL_Profile["AAL Profile"] + class AAL_Application["AAL Application"] + class AAL_Profile_Instance["AAL Profile Instance"] + class AAL_Profile_Queue["AAL Profile Queue"] + + IMS "1" -- "0..n" HW_Accelerator_Manager : manages + HW_Accelerator_Manager "1" -- "0..n" Hardware_Accelerator : manages + Hardware_Accelerator "1" -- "0..n" AAL_Logical_Processing_Unit : resources rep by + Accelerated_Function "1..n" -- "1..n" AAL_Profile : specifies + AAL_Logical_Processing_Unit "1..n" -- "0..n" AAL_Profile : supports + AAL_Logical_Processing_Unit "1" -- "0..n" AAL_Application : uses + AAL_Application "1" -- "0..n" AAL_Profile_Instance : uses + AAL_Profile "0..n" -.- "0..n" AAL_Profile_Instance : is realized by + AAL_Profile_Instance "1" -- "0..n" AAL_Profile_Queue : consists of + AAL_Application "1" -- "0..n" AAL_Profile_Queue : uses + +``` + +Figure 4.2.2-2: AAL Resource Relationship and Cardinality. This UML class diagram illustrates the relationships between various AAL components. The components are: IMS, HW Accelerator Manager, Hardware Accelerator, Accelerated Function, AAL Logical Processing Unit, AAL Profile, AAL Application, AAL Profile Instance, and AAL Profile Queue. Relationships include: IMS (1) manages (0..n) HW Accelerator Manager; HW Accelerator Manager (1) manages (0..n) Hardware Accelerator; Hardware Accelerator (1) resources rep by (0..n) AAL Logical Processing Unit; Accelerated Function (1..n) specifies (1..n) AAL Profile; AAL Logical Processing Unit (1..n) supports (0..n) AAL Profile; AAL Logical Processing Unit (1) uses (0..n) AAL Application; AAL Application (1) uses (0..n) AAL Profile Instance; AAL Profile (0..n) is realized by (0..n) AAL Profile Instance; AAL Profile Instance (1) consists of (0..n) AAL Profile Queue; and AAL Application (1) uses (0..n) AAL Profile Queue. + +**Figure 4.2.2-2: AAL Resource Relationship and Cardinality** + +### 4.2.3 HW Accelerator Manager + +The HW Accelerator Manager (HAM) is responsible for exposing a consistent mechanism to the O-Cloud platform for the discovery, lifecycle management, fault, state/status, performance, configuration, updates/upgrades, and error handling of the HW Accelerator(s) that are part of the O-Cloud Platform Hardware. The HW Accelerator Manager exposes the AALI-C-Mgmt interface towards the IMS. The interfaces between the HW Accelerator and the HAM are vendor specific and not in the scope of AAL specifications. The HW Accelerator Manager is managed by IMS as per Figure 4.2.2-1: High Level AAL Architecture Diagram of this document. The identifier of the HW Accelerator Manager used within the IMS is unique within an O-Cloud instance. + +The HW Accelerator Manager is under the control of the O-Cloud Infrastructure. It is integrated into the Cloud Infrastructure using the O-Cloud Infrastructure's installation procedures. The HW Accelerator Manager shall be certified by the O-Cloud vendor. + +The following list provides a description of capabilities offered by HAM. The list is not exhaustive: + +- Discovery and Life Cycle Management: + - The HW Accelerator Manager provides a mechanism to expose inventory information and capabilities of the physical and logical partitioning of the hardware and software. + - The HW Accelerator Manager provides the ability to discover the capabilities of the HW Accelerator(s). + +#### - Software/ Firmware upgrade services + +- The HW Accelerator Manager allows the update and/or upgrade of the software for a HW Accelerator(s) on the O-Cloud node. An example of this may include the programming or re-programming of a downloadable firmware or driver upgrades. Updates/Upgrades can be done locally or remotely. + +#### - Configuration + +- The HW Accelerator Manager allows the configuration of the HW Accelerator as prescribed by the IMS through the AALI-C-Mgmt interface. The configuration of the HW Accelerator Manager may include HW Accelerator resource assignment to AAL-LPUs. + +#### - Fault and Performance Monitoring: + +- The HW Accelerator Manager allows exposure of faults, logs and performance measurements toward the IMS. + +#### Deployment Scenarios + +The HAM's software is deployed as part of the O-Cloud Platform software. The installation and update of the HAM's software, deployed as a part of O-Cloud platform software, is described section 3.1.2 and section 3.1.6 of Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN [13]. + +The HAM may be located on O-Cloud Nodes designated as part of the clusters used to deploy the AAL Applications (NFs) or otherwise as shown below. The figure shows HAM from the perspective of AAL-C-Mgmt interface termination point. The actual software entities (i.e., vendor specific libraries used by the HAM) for managing the HWA can reside in other locations as well. + +![Diagram illustrating Example HAM software deployment scenarios. The diagram shows four O-Cloud Node Clusters connected to O2 IMS and O2 DMS. Cluster 1 (Not hosting NFs) has a HAM container/VM on the node. Cluster 2 (hosting NFs) has a centralized HAM remote control. Cluster 3 (hosting NFs) has a HAM container/VM within the cluster. Cluster 4 (hosting NFs) has a HAM driver within the local server OS. Each cluster contains nodes with OS, HWA, and server components.](87f8fcf6b00e7e46e19fe0116e83d987_img.jpg) + +The diagram illustrates four deployment scenarios for the Hardware Accelerator Manager (HAM) across O-Cloud Node Clusters, all connected to O2 IMS and O2 DMS: + +- Cluster 1 (Not hosting NFs):** HAM is deployed as a container/VM on the node, which is not used for Network Function (NF) deployment. +- Cluster 2 (hosting NFs):** HAM is a centralized remote control managing HWA resources for the cluster. +- Cluster 3 (hosting NFs):** HAM is a container/VM located within the cluster that is deploying NFs. +- Cluster 4 (hosting NFs):** HAM is a driver located within the local server's operating system (OS). + +Each cluster contains multiple nodes, each with an OS, HWA (Hardware Accelerator), and server component. + +Diagram illustrating Example HAM software deployment scenarios. The diagram shows four O-Cloud Node Clusters connected to O2 IMS and O2 DMS. Cluster 1 (Not hosting NFs) has a HAM container/VM on the node. Cluster 2 (hosting NFs) has a centralized HAM remote control. Cluster 3 (hosting NFs) has a HAM container/VM within the cluster. Cluster 4 (hosting NFs) has a HAM driver within the local server OS. Each cluster contains nodes with OS, HWA, and server components. + +NOTE 1: The scenarios depicted are considered an exemplification of the most common deployment scenarios. Other locations and modelling approaches are not precluded. + +**Figure 4.2.3-1 Example HAM software deployment scenarios** + +### 4.2.4 AAL Interfaces + +The AAL interface API has two distinct parts, the first part corresponds to a set of common APIs (AALI-C) to address all the profile independent aspects of the underlying AAL Implementation(s) within an O-Cloud platform. The second part corresponds to a set of AAL profile specific APIs (AALI-P) which is specific to each defined AAL profile. + +There are two categories of AALI-C interface: + +- AALI-C-Mgmt: OAM management from the HAM toward the O-Cloud IMS for acceleration resources exposed by this interface. +- AALI-C-App: Common operations/actions/events towards the RAN AAL Application for resources exposed by this interface. + +A candidate set of functionalities for AAL services supported by the AAL common API(s) potentially includes (but is not limited to) the following: + +- Inventory Management, Fault, Performance, Configuration Management +- Software/ Firmware upgrade services +- Operations (Query status, Reset/Restart) +- Life Cycle Management of resources exposed by the interface. The AALI-C-Mgmt provides the Life Cycle Management of the HW Accelerator and the AAL-LPU resources. +- Configuration of the state of these AAL-LPU(s) (for example, start, stop, or reset of an AAL-LPU). +- Configuration of various counters and resources associated with AAL-LPU(s) (for example, performance measurements/indicators, performance monitoring metrics, events, faults etc.). +- Discovery of AAL-profile(s) supported by these AAL-LPU(s) and associated configurations etc. +- Abstraction of transport mechanism between the AAL Application and AAL Implementation + +The information model and the exact list of operations and actions applicable across AAL-C-Mgmt and AAL-C-App are defined in [15]. + +The second part of AAL interface corresponds to a set of AAL profile specific APIs (AALI-P) which is specific to each defined AAL profile. The AAL profile can be common across the different AAL Implementation accelerating the same set of AFs. It enables the AAL Application to efficiently offload an AAL profile workload to the AAL Implementation in a consistent way without requiring the HW implementations to expose every single detail of the underlying HW implementation to the AAL Applications. Figure 4.2.4-1 shows examples of the AAL APIs presented to an AAL Application in three different scenarios. + +The AALI-C-App & AALI-P APIs are internal to the AAL Application that utilize them. + +![Figure 4.2.4-1: AAL Application Common and profile APIs. The diagram shows three scenarios of AAL Application components. Each scenario is represented by a large yellow box labeled 'AAL Application'. Inside each yellow box is a dashed-line box labeled 'AAL Interface'. The first scenario shows two boxes: 'AAL Common APIs' and 'AAL Profile A APIs'. The second scenario shows two boxes: 'AAL Common APIs' and 'AAL Profile B APIs'. The third scenario shows three boxes: 'AAL Common APIs', 'AAL Profile B APIs', and 'AAL Profile C APIs'.](c93a25365700ffd5046822a0ed48ee27_img.jpg) + +Figure 4.2.4-1: AAL Application Common and profile APIs. The diagram shows three scenarios of AAL Application components. Each scenario is represented by a large yellow box labeled 'AAL Application'. Inside each yellow box is a dashed-line box labeled 'AAL Interface'. The first scenario shows two boxes: 'AAL Common APIs' and 'AAL Profile A APIs'. The second scenario shows two boxes: 'AAL Common APIs' and 'AAL Profile B APIs'. The third scenario shows three boxes: 'AAL Common APIs', 'AAL Profile B APIs', and 'AAL Profile C APIs'. + +**Figure 4.2.4-1: AAL Application Common and profile APIs** + +### 4.2.5 AAL Deployment in O-Cloud environments + +![Figure 4.2.5-1: Accelerator APIs/Libraries in Container (left) and Virtual Machine Implementations (right). The diagram shows two deployment scenarios for AAL (Accelerator Application Layer) within an O-Cloud Instance. On the left, 'O-RAN Network Function in a container' is shown as a container within the 'O-Cloud Node'. Inside the container, the 'AAL Application' (yellow box) is connected via a dashed line to an 'API/Library' (grey box), which is connected to an 'Acc. Driver' (grey box). Below the container is the 'Host OS' (grey box) with an 'Acc. Driver' (grey box) and 'Compute Svc, with Acceleration'. On the right, 'O-RAN Network Function in a Virtual Machine' is shown as a VM within the 'O-Cloud Node'. Inside the VM, the 'AAL Application' (yellow box) is connected via a dashed line to an 'API/Library' (grey box), which is connected to a 'Guest OS' (grey box) with an 'Acc. Driver' (grey box). Below the VM is the 'Host OS' (grey box) with an 'Acc. Driver' (grey box) and 'Compute Svc, with Acceleration'. Both scenarios show 'DMS' (Data Management Service) and 'IMS' (IP Multimedia Subsystem) services connected to the O-Cloud Instance.](582ce4f3616814db4342b1caa3ca7089_img.jpg) + +Figure 4.2.5-1: Accelerator APIs/Libraries in Container (left) and Virtual Machine Implementations (right). The diagram shows two deployment scenarios for AAL (Accelerator Application Layer) within an O-Cloud Instance. On the left, 'O-RAN Network Function in a container' is shown as a container within the 'O-Cloud Node'. Inside the container, the 'AAL Application' (yellow box) is connected via a dashed line to an 'API/Library' (grey box), which is connected to an 'Acc. Driver' (grey box). Below the container is the 'Host OS' (grey box) with an 'Acc. Driver' (grey box) and 'Compute Svc, with Acceleration'. On the right, 'O-RAN Network Function in a Virtual Machine' is shown as a VM within the 'O-Cloud Node'. Inside the VM, the 'AAL Application' (yellow box) is connected via a dashed line to an 'API/Library' (grey box), which is connected to a 'Guest OS' (grey box) with an 'Acc. Driver' (grey box). Below the VM is the 'Host OS' (grey box) with an 'Acc. Driver' (grey box) and 'Compute Svc, with Acceleration'. Both scenarios show 'DMS' (Data Management Service) and 'IMS' (IP Multimedia Subsystem) services connected to the O-Cloud Instance. + +**Figure 4.2.5-1: Accelerator APIs/Libraries in Container (left) and Virtual Machine Implementations (right)** + +The AAL specifications define the AAL interfaces (i.e AAL-C and AAL-P) and the AAL profiles that may be supported. The AAL-C-App interface is used by AAL Application to access the AAL Implementation encompassing HW Accelerator and associated SW libraries, drivers etc. In Figure 4.2.5-1 two deployment scenarios are shown, one with Containers and the other with Virtual Machines. + +Figure 4.2.5-1 also shows the O-Cloud Infrastructure Management Services and Accelerator management entity (i.e. the HAM). The orchestration of the HAM as a managed entity is outside the scope of the AAL and shall be specified in the O-RAN WG6 O2 specification [11]. + +#### 4.2.5.1 AAL Implementation Software Deployment Options + +The following figures describe AAL Implementation software deployment options. In Figure 4.2.5.1-1: there is an example where the entire AAL Implementation software is deployed as part of the O-Cloud Platform Software [3], and there is no software component dependency between NF Deployments and O-Cloud Platform Software. While in Figure 4.2.5.1-2: and Figure 4.2.5.1-3: there are other examples where part of the AAL Implementation software is deployed as part of the NF Deployment and part of O-Cloud Platform Software. In these and similar cases there is a software component dependency between the NF Deployment and the O-Cloud Platform Software, as such updating AAL Implementation software in the O-Cloud Platform Software may require an update to the NF Deployment, this is outside the scope of the AAL. + +The installation and update of the AAL Implementation software including but not limited to device drivers and libraries, deployed as a part of O-Cloud Platform Software, is described in Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN [12], clause 3.1.2 and 3.1.6. + +In the diagrams below, ‘Container image(s)’ and ‘VM image(s)’ refer specifically to containers or VMs which are being used to run AAL Applications and do not preclude the existence of other containers or images. These diagrams depict several different possible ways in which the AAL Implementation software may be deployed. The AAL Implementation software may exist wholly or partially inside or outside of the specific containers or VMs which are being used to enclose the AAL Applications. + +![Figure 4.2.5.1-1: Example AAL Implementation Software deployment contained within O-Cloud Platform Software only. The diagram shows a dashed box labeled 'Container Image' containing a yellow box labeled 'AAL Application'. Below this is a teal box labeled 'O-Cloud Platform Software' containing a yellow box labeled 'AAL Implementation Software (shared library, Kernel space drivers etc..)'. A double-headed arrow connects the 'AAL Application' box to the 'AAL Implementation Software' box.](b529be5a98bec46f65cbea35096d21b3_img.jpg) + +Figure 4.2.5.1-1: Example AAL Implementation Software deployment contained within O-Cloud Platform Software only. The diagram shows a dashed box labeled 'Container Image' containing a yellow box labeled 'AAL Application'. Below this is a teal box labeled 'O-Cloud Platform Software' containing a yellow box labeled 'AAL Implementation Software (shared library, Kernel space drivers etc..)'. A double-headed arrow connects the 'AAL Application' box to the 'AAL Implementation Software' box. + +**Figure 4.2.5.1-1: Example AAL Implementation Software deployment contained within O-Cloud Platform Software only** + +![Figure 4.2.5.1-2: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and NF Deployment. The diagram shows a dashed box labeled 'Container Image' containing two yellow boxes: 'AAL Application' and 'AAL Implementation Software (static library, user space drivers etc..)'. Below this is a teal box labeled 'O-Cloud Platform Software' containing a yellow box labeled 'AAL Implementation Software (shared library, Kernel space drivers etc..)'. A double-headed arrow connects the 'AAL Implementation Software' box in the container image to the 'AAL Implementation Software' box in the O-Cloud Platform Software.](b03fecb3a34cab8df3bea61affcc269b_img.jpg) + +Figure 4.2.5.1-2: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and NF Deployment. The diagram shows a dashed box labeled 'Container Image' containing two yellow boxes: 'AAL Application' and 'AAL Implementation Software (static library, user space drivers etc..)'. Below this is a teal box labeled 'O-Cloud Platform Software' containing a yellow box labeled 'AAL Implementation Software (shared library, Kernel space drivers etc..)'. A double-headed arrow connects the 'AAL Implementation Software' box in the container image to the 'AAL Implementation Software' box in the O-Cloud Platform Software. + +**Figure 4.2.5.1-2: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and NF Deployment** + +![Diagram illustrating AAL Implementation Software Deployment split between O-Cloud Platform Software and VM Image.](139e863e5c9070e81b5ded169a10bbf3_img.jpg) + +The diagram shows a hierarchical structure of software components. At the bottom is a teal box labeled 'O-Cloud Platform Software'. Inside this box is a yellow box labeled 'AAL Implementation Software (shared library, Kernel space drivers etc.)'. An arrow points from this yellow box up to a larger box labeled 'VM Image'. Inside the 'VM Image' box, there is a grey box labeled 'Guest OS'. Inside the 'Guest OS' box is a yellow box labeled 'AAL Implementation Software (shared library, kernel space drivers etc.)'. Above the 'Guest OS' box, still within the 'VM Image' box, is another yellow box labeled 'AAL Implementation Software (static library, user space drivers etc.)'. At the top of the 'VM Image' box is a yellow box labeled 'AAL Application'. + +Diagram illustrating AAL Implementation Software Deployment split between O-Cloud Platform Software and VM Image. + +**Figure 4.2.5.1-3: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and NF Deployment in a virtual machine environment** + +## 4.3 Relationship with Standards + +The O-RAN AAL interface shall leverage existing standards wherever possible. + +### 4.3.1 Relationship with ETSI + +In [4,5,10], ETSI has specified a generic acceleration and abstraction model as well as acceleration resource management that have served as the basis of this specification. + +ETSI GS NFV-IFA 001 [10] provides a classification of acceleration types and describes several related use cases, for example about compute acceleration when considering Virtual Base Stations (VBS). ETSI GS NFV-IFA 002 [4] specifies an acceleration architectural model for NFV. The acceleration model considers that a single HW device exposes multiple abstract virtual accelerators and multiple instances of these virtual accelerators per VNF. ETSI GS NFV-IFA 002 [4] defines the interfaces between the NFVI and the VNF instances to support this concept. ETSI GS NFV-IFA 019 [5] defines acceleration resource management interfaces between the VIM and the NFVI (e.g., Acceleration Image Management interface). From an NFV orchestration and management perspective, acceleration capabilities are defined as part of the relevant Virtual Compute Resource information elements, i.e., a virtual compute resource (e.g., a VM) can have associated acceleration capabilities from the set of capabilities offered by the acceleration resources. For the relevant descriptors, ETSI GS NFV-IFA 011 [14] details the VirtualComputeDesc information element in VNFD which describes CPU, Memory and acceleration requirements of the virtualisation container (e.g., a VM or a set of OS containers, such as a Pod) realizing a VNFC (i.e., a component of a VNF). For containerized deployments required acceleration capabilities can be described by the extendedResourcesRequests attribute in the OsContainerDesc information element. In addition, in the case of a containerized deployment, requirements about constraints on the placement of the set of one or more OS containers (a Pod) to cluster nodes with certain capabilities, such as acceleration, can also be defined. In both cases (VM-based and OS container-based), the + +1 VDU information element also supports an attribute to request for additional capabilities, being acceleration related +2 capabilities as one possible example. + +3 In ETSI NFV the concept of the abstract virtual accelerator has been devised based on the idea of an extensible para- +4 virtualised device. However, the concept has only been defined considering its use in hypervisor-based virtualization +5 systems and is not ad-hoc applicable to the case of containerized deployments without further analysis. Also, there is no +6 relevant ETSI NFV stage 3 work which can be referenced for the interfaces described in ETSI GS NFV-IFA 002 [4] +7 and ETSI GS NFV-IFA 019 [5]. This specification builds upon the concepts described by the aforementioned ETSI NFV +8 specifications but also goes beyond to consider the advances introduced by cloud native solutions, for example by +9 introducing the concept of LPUs. . + +10 ETSI GR NFV-IFA 046 [15] profiles the NFV-MANO acceleration abstraction framework and compares it to the O- +11 RAN acceleration abstraction solution developed in the context of O-RAN, from which several challenges are further +12 described. A set of recommendations about future work in the NFV framework are derived in the same referenced +13 group report, some considering an alignment between the two designs to make ETSI NFV specifications more +14 expressive to support additional functionality. + +# --- 5. AAL Interface definition General Principles and Requirements + +## 5.1 General Principles + +The set of generic and profile-specific features of the AAL interface between the AAL application and the AAL implementation described in the following subsections are defined from an AAL Application point of view and are related to the AAL-C-App general principles and requirements. + +### 5.1.1 Extensibility + +O-RAN has defined the functions that can be accelerated by the cloud platform based on 3GPP specifications and O-RAN deployment scenarios. However, the AAL should not limit innovation of future implementations and should evolve as the specification requires. To that end, the AAL Application interface shall be extensible to accommodate future revisions of the specification. + +### 5.1.2 HW Independence + +AAL Application interface shall be independent of the underlying AAL Implementation. + +### 5.1.3 Interrupt and Poll Mode + +The AAL Application interface shall support multiple design choices for AAL Application vendors and shall not preclude an AAL Application/HW Accelerator vendor from adopting/supporting an interrupt-driven design or poll-mode design or any combination of both. As such, the AAL Application interface shall support both interrupt mode, poll mode and any combination of interrupt and poll modes for the data-path AAL Application interface. + +### 5.1.4 Discovery and Configuration + +The AAL Application interface shall enable AAL Application to discover and configure AAL-LPU(s). The AAL Application interface shall allow an AAL Application to discover what physical resources have been assigned to it from the upper layers and then to configure said resources for offload operations. + +### 5.1.5 Multiple AAL-LPU Support + +There may be scenarios where multiple AAL-LPUs (either implementing the same or different AAL profile(s) are assigned to a single AAL Application, which uses one or more of these AAL-LPU(s) as needed. The AAL Application interface shall support an AAL Application using one or more AAL-LPU(s) at the same time, as shown in Figure 5.1.5-1. + +![Figure 5.1.5-1: Logical Representation of AAL Application interface support for multiple AAL-LPUs. The diagram shows an 'AAL Application' box at the top. Two arrows labeled 'AAL Interface' point from this box to two separate boxes below. Each of these boxes contains an 'AAL Profile' box and an 'AAL-LPU' box below it.](31b1c9b93e48a8f2cd30783b02d5f825_img.jpg) + +``` + +graph TD + AA[AAL Application] -- AAL Interface --> B1 + AA -- AAL Interface --> B2 + subgraph B1 [ ] + AP1[AAL Profile] + ALPU1[AAL-LPU] + end + subgraph B2 [ ] + AP2[AAL Profile] + ALPU2[AAL-LPU] + end + +``` + +Figure 5.1.5-1: Logical Representation of AAL Application interface support for multiple AAL-LPUs. The diagram shows an 'AAL Application' box at the top. Two arrows labeled 'AAL Interface' point from this box to two separate boxes below. Each of these boxes contains an 'AAL Profile' box and an 'AAL-LPU' box below it. + +**Figure 5.1.5-1: Logical Representation of AAL Application interface support for multiple AAL-LPUs** + +### 5.1.6 AAL offload capabilities + +The AAL Application interface in supporting different AAL profiles and AAL Implementations shall support different offload architectures including look-aside, inline, and any combination of both. An AAL Implementation shall support one or more of these offload architectures depending on the supported AAL profile(s). + +### 5.1.7 Look-aside Acceleration Model + +The AAL Application interface shall support look-aside acceleration model where the AAL Application invokes a HW Accelerator for data processing and receives the result after processing is complete. A look-aside architecture, illustrated in Figure 5.1.7-1, allows the AAL Application to offload AF(s) specified by AAL profile(s) to a HW Accelerator and continue to perform other work in parallel—this could be to continue to execute other software tasks in parallel or to sleep and wait for the HW Accelerator to complete. This model requires the AAL Application interface to support two operations, one for initiating the offload and another for retrieving the output data once complete. + +![Figure 5.1.7-1: AAL Application interface look-aside acceleration model - Data flow. The diagram shows a 'CPU' box containing an 'AAL Application' box. Below it is a 'HW Accelerator' box containing an 'AAL Profile Instance(s)' box. A red arrow labeled 'AAL Interface' points from the AAL Application to the AAL Profile Instance(s). A black arrow points from the AAL Profile Instance(s) back to the AAL Application.](cf236a91022cf9e5b8916dfd3ffc0568_img.jpg) + +``` + +graph TD + subgraph CPU + AA[AAL Application] + end + subgraph HWA [HW Accelerator] + API[AAL Profile Instance(s)] + end + AA -- "AAL Interface (Input)" --> API + API -- "Output" --> AA + +``` + +→ Input to Accelerator +← Output to Accelerator + +Figure 5.1.7-1: AAL Application interface look-aside acceleration model - Data flow. The diagram shows a 'CPU' box containing an 'AAL Application' box. Below it is a 'HW Accelerator' box containing an 'AAL Profile Instance(s)' box. A red arrow labeled 'AAL Interface' points from the AAL Application to the AAL Profile Instance(s). A black arrow points from the AAL Profile Instance(s) back to the AAL Application. + +**Figure 5.1.7-1: AAL Application interface look-aside acceleration model - Data flow** + +### 5.1.8 Inline Acceleration Model + +The AAL Application interface shall support inline acceleration model where the AAL Application, after invoking a HW Accelerator for offloading AF(s) specified by AAL profile(s), does not necessarily retrieve the post processed data. Unlike the look-aside acceleration model where data source/sink is always the AAL Application (i.e., the HW Accelerator always receives the data to be processed from the AAL Application and returns the post processed data to the same), a HW Accelerator operating in inline acceleration mode receives/returns data from/to a different source/destination endpoint than the AAL Application, depending on the direction of data flow (e.g., in downlink (DL) direction versus uplink (UL) direction). Figure 5.1.8-1 shows one possible implementation of an inline acceleration model. + +![Figure 5.1.8-1: AAL Application interface inline acceleration model - Data flow. The diagram shows a CPU block containing an AAL Application block. Below the CPU is a HW Accelerator block. Inside the HW Accelerator are two AAL Profile Instance(s) blocks, each connected to a Tx (Transmit) or Rx (Receive) block. A red arrow labeled 'AAL Interface' points from the AAL Application to the AAL Profile Instance(s). A black arrow points from the AAL Profile Instance(s) to the Tx block. A red arrow points from the Rx block to the AAL Profile Instance(s). A legend at the bottom indicates that a red arrow represents 'Input to Accelerator' and a black arrow represents 'Output to Accelerator'.](1cdd71e72c411d0a37b65ad55a12694c_img.jpg) + +Figure 5.1.8-1: AAL Application interface inline acceleration model - Data flow. The diagram shows a CPU block containing an AAL Application block. Below the CPU is a HW Accelerator block. Inside the HW Accelerator are two AAL Profile Instance(s) blocks, each connected to a Tx (Transmit) or Rx (Receive) block. A red arrow labeled 'AAL Interface' points from the AAL Application to the AAL Profile Instance(s). A black arrow points from the AAL Profile Instance(s) to the Tx block. A red arrow points from the Rx block to the AAL Profile Instance(s). A legend at the bottom indicates that a red arrow represents 'Input to Accelerator' and a black arrow represents 'Output to Accelerator'. + +**Figure 5.1.8-1: AAL Application interface inline acceleration model - Data flow** + +In Figure 5.1.8-1, “Tx” refers to the transmission of the data from the HW Accelerator through an egress port (e.g., an Ethernet interface) to a destination node (e.g., O-RU), while “Rx” refers to the reception of data through an ingress port (e.g., Ethernet interface) to the HW Accelerator from a source node (e.g O-RU). + +While the look-aside architecture (in DL) shall support dataflow from the CPU to the HW Accelerator and back to the CPU before being sent to the egress port (front-haul interface), the inline architecture (in DL) shall support data flow from the CPU to the HW Accelerator and directly from the HW Accelerator to the egress port (front-haul interface), instead of being sent back to the CPU. The typical user plane data flows for accelerating the O-DU High-PHY functions for the look-aside and inline architectures are as follows. + +#### Look-aside architecture user plane dataflow + +CPU ↔ HW Accelerator ↔ CPU ↔ front-haul: for a set of consecutive PHY functions offload (e.g., FEC) + +CPU ↔ HW Accelerator ↔ CPU ↔ HW Accelerator ↔...↔ CPU ↔ front-haul: for a set of non-consecutive PHY functions offload + +#### Inline architecture user plane dataflow + +CPU ↔ HW Accelerator ↔ front-haul: for a set of consecutive PHY functions offload (up to the end of the PHY pipeline) + +Figure 5.1.8-2: illustrates one possible implementation of the look-aside and inline architectures. While a set of PHY-layer functions are offloaded to the HW Accelerator for look-aside acceleration, the entire end-to-end High-PHY pipeline is offloaded to the accelerator for inline acceleration. + +![Figure 5.1.8-2: User plane dataflow paths in look-aside and inline acceleration architectures. The diagram shows two main architectures: Look-Aside model and Inline model. In the Look-Aside model, the O-DU (L2+, PHY, FH) connects to the L2+ on CPU via an L1/L2 Interface*. The L2+ on CPU connects to the High Phy on CPU via an AAL Interface. The High Phy on CPU contains Func. 1, 3, 4, ..., n. The High Phy on CPU connects to the HW Accelerator via an AAL Interface. The HW Accelerator contains Func. 2 on accelerator and Func. N-1 on accelerator. The HW Accelerator connects to the O-RU via a Front Haul Interface (FH (7.2)). In the Inline model, the O-DU connects to the L2+ on CPU via an L1/L2 Interface*. The L2+ on CPU connects to the High Phy on CPU via an Accelerator Interface on CPU. The High Phy on CPU contains the Accelerator Interface on CPU. The High Phy on CPU connects to the HW Accelerator via an AAL Interface. The HW Accelerator contains Func. 2, 2, 3, ..., n-1, n. The HW Accelerator connects to the O-RU via a Front Haul Interface (FH (7.2)). A legend indicates: I/O data flow (double-headed arrow), PHY downlink (red arrow), and PHY uplink (black arrow).](ab1dddf60f3dfcbf5e4ce39b0a85d110_img.jpg) + +Look-Aside model + +Inline model + +O-DU +L2+ +PHY +FH + +L2+ on CPU +L2 + +L1/L2 Interface\* + +High Phy on CPU +Func. 1, Func. 3, Func. 4, ..., Func. n + +AAL Interface + +HW Accelerator +Func. 2 on accelerator, Func. N-1 on accelerator + +Front Haul Interface +FH (7.2) + +O-RU + +\*e.g. FAPI + +I/O data flow + +PHY downlink + +PHY uplink + +Figure 5.1.8-2: User plane dataflow paths in look-aside and inline acceleration architectures. The diagram shows two main architectures: Look-Aside model and Inline model. In the Look-Aside model, the O-DU (L2+, PHY, FH) connects to the L2+ on CPU via an L1/L2 Interface\*. The L2+ on CPU connects to the High Phy on CPU via an AAL Interface. The High Phy on CPU contains Func. 1, 3, 4, ..., n. The High Phy on CPU connects to the HW Accelerator via an AAL Interface. The HW Accelerator contains Func. 2 on accelerator and Func. N-1 on accelerator. The HW Accelerator connects to the O-RU via a Front Haul Interface (FH (7.2)). In the Inline model, the O-DU connects to the L2+ on CPU via an L1/L2 Interface\*. The L2+ on CPU connects to the High Phy on CPU via an Accelerator Interface on CPU. The High Phy on CPU contains the Accelerator Interface on CPU. The High Phy on CPU connects to the HW Accelerator via an AAL Interface. The HW Accelerator contains Func. 2, 2, 3, ..., n-1, n. The HW Accelerator connects to the O-RU via a Front Haul Interface (FH (7.2)). A legend indicates: I/O data flow (double-headed arrow), PHY downlink (red arrow), and PHY uplink (black arrow). + +**Figure 5.1.8-2: User plane dataflow paths in look-aside and inline acceleration architectures.** + +### 5.1.9 AAL Application interface Concurrency and Parallelism + +To enable greater flexibility and design choice by AAL Application vendors, the AAL Application interface shall support multi-threading environment allowing an AAL Application to offload acceleration requests in parallel from several threads. + +### 5.1.10 Separation of Control and User Plane AAL Application interface APIs + +For efficiency and flexibility of AAL Implementation, AAL Application interface shall support separation of control and user plane APIs with appropriate identifiers, as required by different AAL profiles. + +### 5.1.11 Support of Versatile Acceleration Payload + +Range of payload sizes can vary widely, depending on the specific layer of the RAN protocol stack from which the workload for AAL profile(s) is offloaded to a HW Accelerator. AAL Application interface API shall be flexible to support various ranges of payload sizes as required by different AAL profiles. + +### 5.1.12 Support of Different Transport Mechanisms + +The transport between an AAL Application and an AAL Implementation can be of different types (e.g., based on shared memory, PCIe interconnect, over ethernet). The AAL Application interface shall support abstraction of these various transport mechanisms between the AAL Application and the AAL Implementation. + +### 5.1.13 AAL API namespace + +For convenience of AAL Implementation, the AAL shall follow a unique name space for all AAL API functions. + +### 5.1.14 Chaining of AAL Profiles + +AAL profiles specify one or multiple AFs in specific order offloaded to the HWA. To take advantage of multiple AFs offloaded to the same or different HWAs, the AAL Implementation can permit the chaining of AAL Profile(s) executing the AF or set thereof. In such a case, the AAL Implementation redirects the output of preceding AAL Profile as input to the subsequent AAL Profile belonging to the same or different LPU(s) on the same or different HWA(s). Such a chaining of AAL Profiles allows data to be transferred from one AAL Profile to another AAL Profile without the intervention of the AAL Application thereby reducing transfer latencies. Chained AAL Profile Instances can reside on the same or different LPUs and HWAs. However, in this version of specification, only considers the chaining of AAL Profiles on single AAL-LPU, and the HAM announces chained AAL Profiles which can be satisfied on the single AAL- LPU and HWA. Other cases where the chained AAL Profile straddles across multiple AAL-LPUs and HWAs are for further study. + +The use of chaining two AAL Profiles is optional for the AAL Implementation and depends on the AAL Profiles requested by the AAL Application. During CNF deployment as per K8s profile, or VNF deployment as per ETSI profile, AAL Implementation can chain the AAL Profiles to create a chained AAL Profile with more AFs implemented as part of the chained AAL Profile. The chained AAL Profile should conform to the AAL Profile requested by the AAL Application, i.e., the chained AAL Profile has same properties towards the AAL Application as well as the IMS and the DMS. It is the responsibility of the AAL Implementation to announce that the chained profile as an AAL Profile as defined in AAL specifications to which the chain conforms. The first AAL Profile in the chain takes data from the AAL Application and the last AAL Profile returns the transformed data to the AAL Application. + +A chained AAL Profile Instance is valid only if the two or more AAL Profiles form semantically correct sequence of consecutive blocks in the AF processing chain and no intervention is required by the AAL Application for control or data exchanged between the two AAL Profiles. Additionally, the output format of the preceding AAL Profile should match with the input format of the succeeding AAL Profile. + +AAL Profile chaining may be applicable to both inline and look-aside acceleration. The data flows in these cases are depicted in Figure 5.1.14-3: and Figure 5.1.14-4:. + +![Diagram illustrating data flow through unchained AAL Profiles. A central 'AAL Application' box at the top interacts with multiple 'AAL Profile Instance' boxes below it. Solid arrows show data flowing from the AAL Application to each instance and back. A dashed arrow shows a direct path from the AAL Application to the last instance (Instance n) and back, bypassing the intermediate instances.](5a8e870b255ae6f16a4fd2e3dddab3f2_img.jpg) + +``` + +graph TD + AA[AAL Application] + A1[AAL Profile Instance 1] + A2[AAL Profile Instance 2] + Dots[...] + An[AAL Profile Instance n] + + AA --> A1 + A1 --> AA + AA --> A2 + A2 --> AA + AA -.-> An + An -.-> AA + +``` + +Diagram illustrating data flow through unchained AAL Profiles. A central 'AAL Application' box at the top interacts with multiple 'AAL Profile Instance' boxes below it. Solid arrows show data flowing from the AAL Application to each instance and back. A dashed arrow shows a direct path from the AAL Application to the last instance (Instance n) and back, bypassing the intermediate instances. + +**Figure 5.1.14-1: Data flow through unchained AAL Profiles** + +![Diagram illustrating the data flow through chained AAL Profiles. An AAL Application box at the top has a downward arrow to AAL Profile 1. AAL Profile 1, AAL Profile 2, and AAL Profile n are enclosed in a dashed box labeled 'AAL Chained Profile Instance'. Arrows show data flow from AAL Profile 1 to AAL Profile 2, and from AAL Profile 2 to AAL Profile n. An upward arrow from AAL Profile n points back to the AAL Application box.](062e061aa05f1e2d0b5af6dd7f786cbd_img.jpg) + +``` + +graph TD + AA[AAL Application] --> AP1[AAL Profile 1] + subgraph AAL_Chained_Profile_Instance [AAL Chained Profile Instance] + AP1 --> AP2[AAL Profile 2] + AP2 -.-> APn[AAL Profile n] + end + APn --> AA + +``` + +Diagram illustrating the data flow through chained AAL Profiles. An AAL Application box at the top has a downward arrow to AAL Profile 1. AAL Profile 1, AAL Profile 2, and AAL Profile n are enclosed in a dashed box labeled 'AAL Chained Profile Instance'. Arrows show data flow from AAL Profile 1 to AAL Profile 2, and from AAL Profile 2 to AAL Profile n. An upward arrow from AAL Profile n points back to the AAL Application box. + +NOTE 1: In Figure 5.1.14-1 and Figure 5.1.14-2 above, the chained AAL Profile Instance is a data stream transformer that works upon the input data stream to produce output stream. Input data and parameters are passed on from preceding AAL Profile to next. These are provided by the AAL Application in case of the first AAL Profile. The difference is that in Figure 5.1.14-1, the AAL Application would call a series of AAL Profile Instances, while in **Error! Not a valid bookmark self-reference.**, the AAL Application calls only one AAL Profile Instance, which happens to be the chained AAL Profile instance. + +NOTE 2: The mechanisms for transfer of data and parameters to each of the AAL Profile Instances in unchained mode and to the chained AAL Profile Instances follow the AAL-C-App interface's transport as defined in AAL Common API Specifications [14]. The AAL Profiles in the chained mode shall continue to follow the AAL-C-App Interface specified in [14] + +NOTE 3: The AAL-Implementation can configure the chaining of AAL-Profiles during its initialization in order to avoid disruption in the processing chain while the AAL Application is in service. + +**Figure 5.1.14-2: Data flow through chained AAL Profiles** + +The chaining of AAL Profiles is possible across the HWAs and LPUs, however, it is beyond the current scope of document and for future studies. + +The chained look-aside acceleration architecture follows the same dataflow models as look-aside acceleration functions with subtle difference. The first and the last blocks in the chain interfacing the CPU to HW Accelerator support respectively dataflow from the CPU to the accelerator and then from accelerator back to the CPU. All the intermediate blocks support dataflow to and from the preceding and succeeding accelerated functions when those are configured as links in the chain. When not configured as chained accelerated functions, these should support dataflow as in look-aside acceleration. + +Look-aside chained architecture user plane dataflow. + +CPU ↔ HW Accelerator (AF1) ↔ HW Accelerator (AF2) ↔ ... ↔ HW Accelerator (AFn) ↔ CPU ↔ front-haul: for offload of a set of consecutive PHY functions (e.g., FEC) + +CPU ↔ HW Accelerator (AF1) ↔ ... ↔ HW Accelerator (AFn) ↔ CPU ↔ HW Accelerator ↔ ... ↔ CPU ↔ front-haul: for offload of a set of non-consecutive PHY functions + +Figure 5.1.14-3: illustrates the data flow through the chained HW Accelerated functions within an accelerator when configured for consecutive PHY function offload while Figure 5.1.14-4 represents it for non-consecutive PHY function offload. + +![Figure 5.1.14-3: Dataflow through chained lookaside HW Accelerator for consecutive Hi-PHY functions. The diagram shows a 'Look-aside chaining Model' where an O-DU (L2+, PHY, FH) connects to an L2+ on CPU block. This block connects via an L1/L2 Interface* to a High Phy on CPU block. The High Phy on CPU block contains Func. 1 and Func. n, connected by an AAL Interface. Below this is a HW Accelerator block containing Func. 2 on accelerator and Func. N-1 on accelerator. Data flow is shown with I/O data flow (grey double arrow), PHY downlink (red arrow), and PHY uplink (black arrow). The High Phy on CPU block connects to an O-RU via a Front Haul Interface (FH (7.2)).](0e548a8600253c286b93223f864a8a42_img.jpg) + +Figure 5.1.14-3: Dataflow through chained lookaside HW Accelerator for consecutive Hi-PHY functions. The diagram shows a 'Look-aside chaining Model' where an O-DU (L2+, PHY, FH) connects to an L2+ on CPU block. This block connects via an L1/L2 Interface\* to a High Phy on CPU block. The High Phy on CPU block contains Func. 1 and Func. n, connected by an AAL Interface. Below this is a HW Accelerator block containing Func. 2 on accelerator and Func. N-1 on accelerator. Data flow is shown with I/O data flow (grey double arrow), PHY downlink (red arrow), and PHY uplink (black arrow). The High Phy on CPU block connects to an O-RU via a Front Haul Interface (FH (7.2)). + +**Figure 5.1.14-3: Dataflow through chained lookaside HW Accelerator for consecutive Hi-PHY functions.** + +![Figure 5.1.14-4: Dataflow through chained lookaside HW Accelerator for consecutive and non-consecutive PHY. The diagram shows a 'Look-aside chaining Model' where an O-DU (L2+, PHY, FH) connects to an L2+ on CPU block. This block connects via an L1/L2 Interface* to a High Phy on CPU block. The High Phy on CPU block contains Func. 1, Func. 4, and Func. n, connected by an AAL Interface. Below this is a HW Accelerator block containing Func. 2, Func. 3, Func. 5, and Func. N-1. Data flow is shown with I/O data flow (grey double arrow), PHY downlink (red arrow), and PHY uplink (black arrow). The High Phy on CPU block connects to an O-RU via a Front Haul Interface (FH (7.2)).](a6ffb8c66aa91135e92c71767459313d_img.jpg) + +Figure 5.1.14-4: Dataflow through chained lookaside HW Accelerator for consecutive and non-consecutive PHY. The diagram shows a 'Look-aside chaining Model' where an O-DU (L2+, PHY, FH) connects to an L2+ on CPU block. This block connects via an L1/L2 Interface\* to a High Phy on CPU block. The High Phy on CPU block contains Func. 1, Func. 4, and Func. n, connected by an AAL Interface. Below this is a HW Accelerator block containing Func. 2, Func. 3, Func. 5, and Func. N-1. Data flow is shown with I/O data flow (grey double arrow), PHY downlink (red arrow), and PHY uplink (black arrow). The High Phy on CPU block connects to an O-RU via a Front Haul Interface (FH (7.2)). + +**Figure 5.1.14-4: Dataflow through chained lookaside HW Accelerator for consecutive and non-consecutive PHY.** + +## 5.2 High-PHY Profile Specific Principles + +The set of features of AAL described in the following subsections are relevant for inline High-PHY AAL profiles (profile names with suffix ‘\_HIGH-PHY’) defined in Chapter 5 + +### 5.2.1 Separation of Cell and Slot Level Parameter Configurations + +In general, “cell-specific” (typically static or semi-static in nature) parameters change less frequently than “slot-specific” (typically dynamic in nature, specific to PHY channels/signals) parameters associated with inline, High-PHY AAL profiles. Hence, for optimizing signalling overhead, the AAL Application interface shall support configuration of “cell-specific” and “slot-specific” parameters to the AAL Implementation using separate AAL Application interface API functions. It is noteworthy that the cell/slot specific configurations can include both control and user planes. + +### 5.2.2 SFN/slot-based Synchronization + +The AAL Application interface shall support system frame number (SFN) based or slot-based synchronization between the AAL Application and the AAL Implementation supporting inline, high-PHY AAL profiles. + +### 5.2.3 Compatibility with O-RAN FH interface + +The functional split between the O-DU and the O-RU remains as defined by the WG4 OFH interface [17] and the AAL Application interface API shall be compatible with O-RAN FH interface (7.2-x split) to enable communication between the O-DU AAL Application and O-RU via AAL Implementation as required by inline, High-PHY AAL profile(s). + +### 5.2.4 Inline Profile for High-PHY Stack + +Inline data flow for the AAL Profile that specifies a complete stack of High-PHY functions implies that the set of Accelerated Functions is constituted by the entire U-plane processing of the High-PHY channels or signals (with 7-2x PHY functional split) and the IQ data (in DL) or decoded bits (in UL) (post processing) and these are transferred directly from the HW Accelerator to the Fronthaul interface (in DL) or to the Layer 2 (in UL). + +Inline acceleration for AAL Profiles that specify a partial stack of the High-PHY for UL and for DL Accelerated Functions is also possible; in such case only parts of the U-Plane, i.e., not all the functions of the High-PHY stack of a given channel, may be offloaded to a HW Accelerator. For inline acceleration of a partial High-PHY stack, the IQ data or decoded bits are also transferred directly from the HW Accelerator to the Fronthaul (in DL) and to the non-accelerated part of the High-PHY stack (in UL). The set of Accelerated Functions that are offloaded in Inline mode for acceleration of a partial High-PHY stack would be AAL Profile specific. The support of AAL Profiles that specify the support of partial High-PHY stack is for future study. + +![Figure 5.2.4-1: Partial Inline Model for AAL Hi-PHY Profile. The diagram illustrates the data flow between the O-DU, L2+ on CPU, High Phy on CPU, HW Accelerator, and O-RU. The O-DU (L2+, PHY, FH) connects to the L2+ on CPU via the L1/L2 Interface*. The L2+ on CPU connects to the High Phy on CPU via the L1/L2 Interface*. The High Phy on CPU contains Func. 1, Func. 2, and Func. n. The HW Accelerator contains Func. 3, Func. 4, and Func. N-1. The High Phy on CPU and HW Accelerator are connected via the AAL Interface. The High Phy on CPU connects to the O-RU via the Front Haul Interface FH (7.2). The HW Accelerator connects to the O-RU via the Front Haul Interface FH (7.2). The diagram also shows I/O data flow and PHY downlink/uplink directions.](6fbff1efa94e5786eceb02cd60c69698_img.jpg) + +The diagram illustrates the Partial Inline Model for AAL Hi-PHY Profile. It shows the following components and their interactions: + +- O-DU (L2+, PHY, FH)**: The O-DU connects to the L2+ on CPU via the L1/L2 Interface\*. +- L2+ on CPU**: Contains the L2 layer. It connects to the High Phy on CPU via the L1/L2 Interface\*. +- High Phy on CPU**: Contains Func. 1, Func. 2, and Func. n. It connects to the HW Accelerator via the AAL Interface. +- HW Accelerator**: Contains Func. 3, Func. 4, and Func. N-1. It connects to the O-RU via the Front Haul Interface FH (7.2). +- O-RU**: The O-RU connects to the High Phy on CPU via the Front Haul Interface FH (7.2). + +The diagram also shows I/O data flow and PHY downlink/uplink directions. The I/O data flow is indicated by a double-headed arrow. The PHY downlink is indicated by a red arrow pointing from the High Phy on CPU to the HW Accelerator. The PHY uplink is indicated by a black arrow pointing from the HW Accelerator to the High Phy on CPU. + +Figure 5.2.4-1: Partial Inline Model for AAL Hi-PHY Profile. The diagram illustrates the data flow between the O-DU, L2+ on CPU, High Phy on CPU, HW Accelerator, and O-RU. The O-DU (L2+, PHY, FH) connects to the L2+ on CPU via the L1/L2 Interface\*. The L2+ on CPU connects to the High Phy on CPU via the L1/L2 Interface\*. The High Phy on CPU contains Func. 1, Func. 2, and Func. n. The HW Accelerator contains Func. 3, Func. 4, and Func. N-1. The High Phy on CPU and HW Accelerator are connected via the AAL Interface. The High Phy on CPU connects to the O-RU via the Front Haul Interface FH (7.2). The HW Accelerator connects to the O-RU via the Front Haul Interface FH (7.2). The diagram also shows I/O data flow and PHY downlink/uplink directions. + +Figure 5.2.4-1: Partial Inline Model for AAL Hi-PHY Profile + +# 6. AAL-LPU Principles + +## 6.1 Overview + +This section discusses about AAL-LPU(s) presented to AAL Applications using the AAL Application interface. An AAL-LPU should not be confused with a physical HW Accelerator. Within a process address space each AAL-LPU shall abstract the AAL Application from underlying HW Accelerator. + +The following list provides a description of capabilities and characteristics of AAL-LPUs: + +- An AAL-LPU maps to a single HW Accelerator. An AAL-LPU can be identified uniquely within a HW Accelerator. +- A HW Accelerator may support 1 to N AAL-LPU's. +- Each AAL-LPU shares the resources of the associated HW Accelerator with other AAL-LPU(s) mapped to the same HW Accelerator. AAL-LPU can also represent a hard partition of the HW Accelerator where resources are dedicated to the partition. +- Mapping of HW Accelerator resources to AAL-LPU shall be configurable from O2 interface +- An AAL-LPU may support more than one AAL profile. For each supported AAL profile, an AAL-LPU may execute 0 to N AAL-Profile-Instances. +- An AAL-LPU can be assigned to a single POD or VM. Multiple LPU's can be assigned to a POD or VM. +- An AAL-LPU can provide service to 0 or more AAL Applications within a POD or VM. +- AAL-LPU is a virtual Managed Element as defined in [13]. + +Depending on HW design and implementation choice, a HW Accelerator may accelerate multiple profiles or offer support for sharing HW Accelerator resources between multiple threads, processes, VMs, PODs. For this reason, a second abstract construct known as AAL Profile Queue can optionally be used to + +- distinguish between multiple supported AAL profiles per AAL-LPU +- prioritize access to AAL-LPU resources +- group operation requests +- allow parallel access through AAL Application interface for multiple threads + +As an abstract construct, an AAL Profile Queue does not reflect a HW design specification or requirement. + +From the AAL Application point of view, an AAL Profile queue is exposed by an AAL Profile Instance + +- an AAL Profiles Instances exposes one or more AAL Profile Queues +- The AAL Profile Queue optionally also supports priority, allowing the AAL Application to schedule jobs of different priorities. + +NOTE: An AAL Profile Queue can be used by an AAL Application to share AAL-LPU resources between threads/cores belonging to the same process address space + +NOTE: An AAL Application may use multiple AAL Profile Queues to access different AAL Profile Instances supported by an AAL-LPU + +## 6.2 LPU Deployment and Operation + +### 6.2.1 Example AAL-LPU Mapping + +The following Section contains example deployments mapping AAL-LPUs to AAL Applications. The labels ‘profile-instanceID’ and ‘queueID’ in the following diagrams denote AAL Profile Instance object handle and identifier of an AAL Profile Queue respectively. + +- **Scenario 1: Basic implementation:** A HW Accelerator supports a single AAL-LPU which exposes a single AAL-Profile-Instance for one AAL Application to use + +![Diagram illustrating Scenario 1: Basic implementation. An AAL Application (API(profile-instanceID, queueID)) is connected to an AAL Profile Instance, which is connected to AAL-LPU0, which is connected to a HW Accelerator (Physical).](aada4b98ce0e528739e06c6c7f276f7d_img.jpg) + +``` + +graph TD + subgraph AAL_Application [AAL Application] + API[API(profile-instanceID, queueID)] + API --- AAL_Profile_Instance[AAL Profile Instance] + end + AAL_Profile_Instance <--> AAL_LPU0[AAL-LPU0] + AAL_LPU0 <--> HW_Accelerator[HW Accelerator (Physical)] + +``` + +Diagram illustrating Scenario 1: Basic implementation. An AAL Application (API(profile-instanceID, queueID)) is connected to an AAL Profile Instance, which is connected to AAL-LPU0, which is connected to a HW Accelerator (Physical). + +A HW Accelerator supports a single AAL LPU which exposes a single AAL Profile Queue for one application to use + +**Figure 6.2.1-1: Scenario 1: A single AAL LPU exposes a single AAL Profile Queue used by a single AAL Application.** + +**Scenario 2: Basic Multi Application Support:** A HW Accelerator supports multiple AAL LPUs for multiple AAL Applications + +![Diagram showing two AAL Applications, each containing an AAL Profile Instance and an AAL-LPU0, connected to a single HW Accelerator (Physical).](9967fc65e43c0f351cc5279245b653cf_img.jpg) + +The diagram illustrates a multi-application architecture. At the top, there are two identical 'AAL Application' blocks. Each block contains an 'API(profile-instanceID, queueID)' interface, represented by a vertical stack of four small squares. Below the API is an 'AAL Profile Instance' box, which is connected to an 'AAL-LPU0' box via a double-headed vertical arrow. Both the 'AAL Profile Instance' and 'AAL-LPU0' boxes are enclosed within a larger yellow box representing the 'AAL Application'. Below each 'AAL-LPU0' box is a grey box labeled 'HW Accelerator (Physical)'. A double-headed vertical arrow connects each 'AAL-LPU0' box to its corresponding 'HW Accelerator (Physical)' box. The two 'HW Accelerator (Physical)' boxes are positioned side-by-side, sharing a single physical accelerator. + +Diagram showing two AAL Applications, each containing an AAL Profile Instance and an AAL-LPU0, connected to a single HW Accelerator (Physical). + +#### Multi application support + +Example showing multiple applications supported by a single HW accelerator + +**Figure 6.2.1-2: A single HW Accelerator supporting two LPU's each assigned to individual AAL Applications** + +- **Scenario 3: Multiple Accelerator Support:** Mapping example showing multiple HW Accelerators assigned to a single AAL Application + +![Diagram showing a single AAL Application containing two AAL-LPU0 and AAL-LPU1, each connected to a separate HW Accelerator (Physical).](e47aaa02ea47a0178b11996bb322f341_img.jpg) + +The diagram illustrates a multi-accelerator architecture. At the top, there is a single 'AAL Application' block. It contains two identical 'API(profile-instanceID, queueID)' interfaces, each represented by a vertical stack of four small squares. Below each API is an 'AAL Profile Instance' box, which is connected to an 'AAL-LPU0' box via a double-headed vertical arrow. Both the 'AAL Profile Instance' and 'AAL-LPU0' boxes are enclosed within a larger yellow box representing the 'AAL Application'. Below each 'AAL-LPU0' box is a grey box labeled 'HW Accelerator (Physical)'. A double-headed vertical arrow connects each 'AAL-LPU0' box to its corresponding 'HW Accelerator (Physical)' box. The two 'HW Accelerator (Physical)' boxes are positioned side-by-side, each supporting a separate LPU within the same application. + +Diagram showing a single AAL Application containing two AAL-LPU0 and AAL-LPU1, each connected to a separate HW Accelerator (Physical). + +#### Multi accelerator support + +Example showing multiple HW accelerators assigned to a single application + +**Figure 6.2.1-3: Two HW Accelerators each supporting a single AAL-LPU assigned to a single AAL Application.** + +- **Scenario 4: Multi Queue Support:** AAL LPU mapping showing multiple AAL Profile Queue support + +![Diagram of AAL Application architecture showing a single AAL LPU supporting two AAL Profile Instances.](23216cf856f906873749fe3da83094f9_img.jpg) + +The diagram illustrates the architecture of an AAL Application. At the top, a yellow box labeled "AAL Application" contains the API (profile-instanceID, queueID). Below the API, there are two vertical stacks of three small squares each, representing AAL Profile Queues. These queues are connected to a single "AAL Profile Instance" box. This instance is connected via a double-headed arrow to an "AAL-LPU0" box. Finally, the AAL-LPU0 is connected via a double-headed arrow to a grey box labeled "HW Accelerator (Physical)". + +Diagram of AAL Application architecture showing a single AAL LPU supporting two AAL Profile Instances. + +#### Multi queue support + +A single AAL LPU exposes two AAL Profile Queues used by a single AAL Application + +**Figure 6.2.1-4: A single AAL LPU exposes two AAL Profile Queues used by a single AAL Application.** + +- **Scenario 5: Multi Profile Support:** Mapping example showing multi-function support + +![Diagram of AAL Application architecture showing a single AAL LPU supporting two AAL Profile Instances.](4bdc37f4d404f4b668a7eef1562d6a2d_img.jpg) + +The diagram illustrates the architecture of an AAL Application for multi-profile support. At the top, a yellow box labeled "AAL Application" contains two API (profile-instanceID, queueID) labels. Below each API label, there is a vertical stack of three small squares, representing two separate AAL Profile Queues. Each queue is connected to its own "AAL Profile Instance" box. Both AAL Profile Instances are connected via double-headed arrows to a single "AAL-LPU0" box. Finally, the AAL-LPU0 is connected via a double-headed arrow to a grey box labeled "HW Accelerator (Physical)". + +Diagram of AAL Application architecture showing a single AAL LPU supporting two AAL Profile Instances. + +#### Multi Profile Support + +A single AAL LPU supporting two AAL Profile Instances exposes two AAL Profile Queues used by a single AAL Application + +**Figure 6.2.1-5: A single AAL LPU supporting two AAL Profile Instances exposes two AAL Profile Queues used by a single AAL Application.** + +- **Scenario 6: Chained Profile Support:** Mapping example showing a multi-profile chained AAL Profile Instance on an AAL-LPU + +![Diagram illustrating AAL-LPU Mapping example showing chained profile support. The diagram shows an AAL Application box containing an API(profile-instanceID, queueID) interface, a vertical stack of three small squares, and an AAL Chained Profile Instance box. The AAL Chained Profile Instance box contains AAL Profile 1 and AAL Profile 2, connected by a right-pointing arrow. Below the AAL Chained Profile Instance box is an AAL-LPU0 box, connected by a double-headed vertical arrow. Below the AAL-LPU0 box is a HW Accelerator (Physical) box, connected by a double-headed vertical arrow.](da3e3e7121a832530eee4601dba49053_img.jpg) + +Diagram illustrating AAL-LPU Mapping example showing chained profile support. The diagram shows an AAL Application box containing an API(profile-instanceID, queueID) interface, a vertical stack of three small squares, and an AAL Chained Profile Instance box. The AAL Chained Profile Instance box contains AAL Profile 1 and AAL Profile 2, connected by a right-pointing arrow. Below the AAL Chained Profile Instance box is an AAL-LPU0 box, connected by a double-headed vertical arrow. Below the AAL-LPU0 box is a HW Accelerator (Physical) box, connected by a double-headed vertical arrow. + +#### Chained Profile Support + +Example showing multiple AAL Profiles (1 & 2) chained together to implement a single AAL Profile Instance on an AAL-LPU which is equivalent to Profile 1 + Profile 2 + +**Figure 6.2.1-6: AAL-LPU Mapping example showing chained profile support** + +### 6.2.2 Statistics + +The AAL Application interface shall provide an AAL Application with general statistics upon request. Statistics may include but not limited to operation counts and error counts. + +### 6.2.3 Memory Management + +O-RAN network functions (O-DU, O-CU, etc.) will be responsible for input, output and operation structure memory allocation and freeing, using AAL defined memory management functions. All other AAL Application memory is not required to use the AAL memory management functions. + +Device Drivers are free to manage their own internal memory, DMA implementation as needed, the AAL specification does not add any memory requirements to device driver. + +Each AAL Implementation shall define its own memory requirements and implement its own memory backing if needed. + +Each AAL Implementation may define its own operation memory structure and allocation if needed. + +### 6.2.4 Run Time Configurations + +Operations are requested to the AAL-LPU to execute specific HW Accelerated Function(s). Each operation shall be represented by an operation struct that shall define all necessary metadata, configurations and information required for the operation to be processed on an AAL-LPU. The operation structs shall define the operation type to be performed, including an operation status and reference to the AAL profile specific operation data which can vary in size and content depending on the AAL profile. Each AAL profile shall define its own operation structure for its specific functions. + +### 6.2.5 AAL Profile(s) offload, processing status query and processed data retrieval + +An AAL Application aggregates one or more AAL profile(s) and offload to the AAL Implementation using a single AAL Application interface API invocation. As one example, for High-PHY AAL profiles defined in clause 7, multiple AAL profiles (where an AAL profile refers to a PHY channel/signal for one or more than one cell(s) and one or more than one UE(s)) scheduled within a slot can be aggregated and offloaded to an AAL-LPU by the AAL Application using a single AAL Application interface API invocation. + +The processing status of offloaded/enqueued AAL profile(s) can be queried by the AAL Application in an ‘asynchronous’ manner, i.e., not necessarily in the same order in which the AAL profile(s) are offloaded. In case the AAL Application retrieves the post-processed data from the AAL Implementation, a ‘processing status query’ request can be bundled with a ‘processed data retrieval/dequeue’ request. In general, status query and dequeue request corresponding to multiple enqueue requests can be bundled together by the AAL Application and invoked through a single AAL Application interface API function. + +### 6.2.6 AAL-LPU Exposure + +#### 6.2.6.1 Overview + +After using the HW Accelerator Manager to create the AAL-LPU(s) and the profiles supported, we can then expose it to the AAL Application (e.g. in Kubernetes® it will be part of the POD environment variables). The goal of this section is to abstract the way the AAL-LPU and its supported profiles are exposed to the AAL Application in order to achieve AAL Application portability. Hence, the AAL-LPU and its profile(s) shall be exposed the AAL Application in an abstracted descriptor. + +As of today many implementations refer to the AAL-LPU by its PCI address and describe a single profile for the entire HW Accelerator, meaning exposure of one single profile for all LPUs supported. This section provides step-by-step example that shows how the AAL-LPU could be exposed to abstract the PCIe address and the profile(s) supported by the AAL-LPU. Although the below example is a Kubernetes® example, the outcome of it is independent of orchestration technology supported. + +#### 6.2.6.2 Example + +##### 6.2.6.2.1 AAL-LPU Configuration + +1. A given HW Accelerator can support 16 AAL-LPUs and FEC LDPC, PHY profiles but the default setup of the AAL-LPUs is FEC: + +![Diagram showing 16 AAL-LPUs (LPU-1 to LPU-16) each supporting FEC, connected to a HW Accelerator (Physical).](207760e01584b5d1d7b82a2d93666199_img.jpg) + +``` + +graph TD + LPU1[LPU-1 +FEC] --- HW[HW Accelerator (Physical)] + LPU2[LPU-2 +FEC] --- HW + LPU3[LPU-3 +FEC] --- HW + Dots[...] --- HW + LPU16[LPU-16 +FEC] --- HW + +``` + +Diagram showing 16 AAL-LPUs (LPU-1 to LPU-16) each supporting FEC, connected to a HW Accelerator (Physical). + +**Figure 6.2.6.2.1-1: Example AAL-LPU and profile supported** + +2. Now assume HW Accelerator Manager configured the HW Accelerator as follow: + +- LPU-1 supports FEC version 01, PHY and LDPC version 01 profiles +- LPU-2 supports LDPC version 02 profile +- LPU-3 supports LDPC version 02 profile +- LPU-4 supports LDPC version 02 profile + +![Figure 6.2.6.2.1-2: Example HW Accelerator configuration. A diagram showing four LPU blocks (LPU-1, LPU-2, LPU-3, LPU-3) stacked on top of a HW Accelerator (Physical) block. LPU-1 contains FECv01 & PHY & LDPCv01. LPU-2 contains LDPCv02. LPU-3 contains LDPCv02. LPU-3 contains LDPCv02.](2188319348af5a15a62689fa8b585c11_img.jpg) + +Figure 6.2.6.2.1-2: Example HW Accelerator configuration. A diagram showing four LPU blocks (LPU-1, LPU-2, LPU-3, LPU-3) stacked on top of a HW Accelerator (Physical) block. LPU-1 contains FECv01 & PHY & LDPCv01. LPU-2 contains LDPCv02. LPU-3 contains LDPCv02. LPU-3 contains LDPCv02. + +Figure 6.2.6.2.1-2: Example HW Accelerator configuration + +3. Assigning it to a the a vDU POD and exposing the two LPU/Profiles needed by vDU (in green): + +![Figure 6.2.6.2.1-3: Example assignment of AAL-LPUs and supported profiles to POD. A diagram showing the flow from a Manifest to a POD environment variables block, and then to a HW Accelerator (Physical) block. The Manifest block contains resources, requests, and memory. The POD environment variables block contains #env and three LPU addresses. The HW Accelerator (Physical) block contains LPU-1, LPU-2, and LPU-3. A callout box points to the Manifest block with the text 'How many LPUs of a kind are requested'.](153f104687072c1194f50ebe419bfff9_img.jpg) + +Figure 6.2.6.2.1-3: Example assignment of AAL-LPUs and supported profiles to POD. A diagram showing the flow from a Manifest to a POD environment variables block, and then to a HW Accelerator (Physical) block. The Manifest block contains resources, requests, and memory. The POD environment variables block contains #env and three LPU addresses. The HW Accelerator (Physical) block contains LPU-1, LPU-2, and LPU-3. A callout box points to the Manifest block with the text 'How many LPUs of a kind are requested'. + +Figure 6.2.6.2.1-3: Example assignment of AAL-LPUs and supported profiles to POD + +We can see that the AAL-LPU resources requested in the manifest is translated in the POD environment to three AAL-LPU addresses plus the strings that describe the profiles supported by the LPU. Please note that the AAL Application will be able to query the AAL-LPUs and their supported profiles via the AAL-C-App API. + +##### 6.2.6.2.2 AAL-LPU Control by the AAL Application + +The figure below shows how the AAL Application for a vDU can create several PHY profiles on LPU-1, for example, PHY Profile-1 handles cell-1 and PHY Profile-2 handles cell-2, as well as running different LDPC profiles on different LPUs and all in the same HW Accelerator. As mentioned before the AAL Application can query what profiles supported by reading the POD environment variables or by querying it using the AAL-C-App API. + +![Diagram showing AAL-LPU Control by the AAL Application. A diagram showing three LPU blocks (LPU-1, LPU-2, LPU-3) stacked on top of a HW Accelerator (Physical) block. Above LPU-1, there are six vertical blocks representing profiles: FECv01 Profile Instance 1, FECv02 Profile Instance 1, PHY Profile Instance 1, PHY Profile Instance 2, LDPCv02 Profile Instance 1, and LDPCv02 Profile Instance 1. A callout box points to the first two profile blocks with the text 'The numbers represent an application perspective (e.g. handlers)'.](f7b67189401efa9aec7b7b7c77b9fdf3_img.jpg) + +Diagram showing AAL-LPU Control by the AAL Application. A diagram showing three LPU blocks (LPU-1, LPU-2, LPU-3) stacked on top of a HW Accelerator (Physical) block. Above LPU-1, there are six vertical blocks representing profiles: FECv01 Profile Instance 1, FECv02 Profile Instance 1, PHY Profile Instance 1, PHY Profile Instance 2, LDPCv02 Profile Instance 1, and LDPCv02 Profile Instance 1. A callout box points to the first two profile blocks with the text 'The numbers represent an application perspective (e.g. handlers)'. + +###### Figure 6.2.6.2.2-1: Example AAL Application configured AAL-Profile-Instances + +##### 6.2.6.2.3 AAL-LPU resource tracking + +It is a key to be able to track the AAL-LPU as a resource for providing the AAL Application with acceleration resources it needs otherwise the attempt to create the NF will fail due to insufficient resources available. + +There are few notes related to the tracking of the AAL-LPU resources in relation to the example's above in : + +- If another POD needs to use the LDPC profile, Kubernetes will allow it as 2 out of 3 were used (LPU-4 supports it). +- If another POD needs to use FEC and PHY profiles (FEC&PHY), Kubernetes will reject it as only one LPU is configured this way. +- We need to consider if a logic is needed to track the AAL-LPU availability from the SMO. For example, a total of ten AAL-LPU/FEC profiles available in a cluster, three is being used by a deployment, seven left for a new deployment. The seven available could be revealed to the user or automation at the SMO level when considering additional deployments. + +The conclusion is that the SMO shall be able to track the AAL-LPU as a resource and its availability. + +# 7. AAL Profiles + +An AAL profile specifies a set of Accelerated Functions that a Hardware Accelerator processes on behalf of an AAL Application within an O-RAN Cloudified Network Function (e.g. O-DU, O-CU etc.). Accordingly, AAL profiles can be categorized as O-DU AAL profiles, O-CU AAL profiles and so on. The following sections describe these different AAL profile categories in further details. + +## 7.1 O-DU AAL Profiles + +An O-DU AAL profile can specify a set of Accelerated Functions within the O-DU protocol stack. These functions may belong to a single layer (e.g., PHY) or span across multiple layers (e.g., PHY and MAC) within O-DU. The current O-DU AAL profiles being studied by O-RAN WG6 are focusing on Accelerated Functions from PHY layer of O-DU. + +### 7.1.1 O-DU Protocol Stack Reference + +Figure 7.1.1-1: illustrates the building blocks for processing various O-DU PHY layer Downlink (DL) channels and signals (with 7.2-x functional split between O-DU and O-RU) defined by 3GPP in [6] & [7] as part of 5G NR specification. + +![Figure 7.1.1-1: O-DU PHY processing blocks for 5G NR Downlink. The diagram shows the processing flow for PDSCH, PDCCH, PBCH, and PSS/SSS channels. The PDSCH path includes TB CRC attachment, CB segmentation, LDPC encoding, rate matching, CB concatenation, scrambling, modulation, and layer mapping. The PDCCH path includes CRC attachment, polar encoding, rate matching, scrambling, and modulation (QPSK). The PBCH path includes payload generation, scrambling, TB CRC attachment, polar encoding, rate matching, data scrambling, and modulation (QPSK). The PSS/SSS path includes sequence generation and modulation. All paths include precoding, RE mapping, and IQ compression. The diagram is organized into columns for each channel type and rows for the processing blocks. A dashed box indicates the 7-2x lower layer split between O-DU and O-RU.](76837c3cc481a9acdf914d02c7ea5973_img.jpg) + +| L2+ | | | | | | | +|-------------------------------------|--|---------------------|--|-------------------------|--|-------------------------| +| <b>PDSCH TB(s)</b> | | <b>PDCCH (DCI)</b> | | <b>PBCH TB</b> | | | +| TB CRC attachment | | CRC attachment | | PBCH payload generation | | | +| CB segmentation + CB CRC attachment | | Polar encoding | | Scrambling | | | +| LDPC encoding | | Rate matching | | TB CRC attachment | | | +| Rate matching | | Scrambling | | Polar encoding | | | +| CB concatenation | | Modulation (QPSK) | | Rate matching | | | +| Scrambling | | Modulation | | Data scrambling | | <b>PSS/SSS</b> | +| Modulation | | Modulation | | Modulation (QPSK) | | <b>PBCH DM-RS</b> | +| Layer mapping | | Modulation | | Modulation | | <b>CSI-RS/PT-RS/TRS</b> | +| Sequence generation | | Sequence generation | | Sequence Generation | | | +| Modulation | | Modulation | | Modulation | | | +| Precoding* | | Precoding* | | Precoding* | | | +| RE mapping | | RE mapping | | RE mapping | | | +| IQ compression* | | IQ compression* | | IQ compression* | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | + +Figure 7.1.1-1: O-DU PHY processing blocks for 5G NR Downlink. The diagram shows the processing flow for PDSCH, PDCCH, PBCH, and PSS/SSS channels. The PDSCH path includes TB CRC attachment, CB segmentation, LDPC encoding, rate matching, CB concatenation, scrambling, modulation, and layer mapping. The PDCCH path includes CRC attachment, polar encoding, rate matching, scrambling, and modulation (QPSK). The PBCH path includes payload generation, scrambling, TB CRC attachment, polar encoding, rate matching, data scrambling, and modulation (QPSK). The PSS/SSS path includes sequence generation and modulation. All paths include precoding, RE mapping, and IQ compression. The diagram is organized into columns for each channel type and rows for the processing blocks. A dashed box indicates the 7-2x lower layer split between O-DU and O-RU. + +**Figure 7.1.1-1: O-DU PHY processing blocks for 5G NR Downlink** + +The O-DU PHY layer in downlink consists of the following physical channels and reference signals: + +- Physical Downlink Shared Channel (PDSCH) and associated Demodulation Reference Signal (PDSCH DM-RS). +- Physical Downlink Control Channel (PDCCH) and associated Demodulation Reference Signal (PDCCH DM-RS). +- Synchronization Signal Block (SSB) consisting of + - Physical Broadcast Channel (PBCH) and associated DMRS (PBCH DM-RS). + - Primary Synchronization Signal (PSS). + - Secondary Synchronization Signal (SSS). + +- 1 • Channel State Information-Reference Signal (CSI-RS) and Tracking Reference Signal (TRS). +- 2 • Phase Tracking Reference Signal (PT-RS) for DL. +- 3 The downlink physical channels (PDSCH, PDCCH, PBCH) carry information originating from higher layers (i.e. layer +- 4 2 and above). +- 5 The downlink physical layer processing of data channel (PDSCH) carrying transport blocks consists of the following +- 6 steps: +- 7 TB CRC attachment: Error detection is provided on each transport block (TB) through a Cyclic Redundancy Check +- 8 (CRC). Refer to Subclause 7.2.1 in [7] for details. +- 9 CB segmentation and CRC attachment: The transport block is segmented when it exceeds the code block (CB) size +- 10 specified by 3GPP [7]. Code block segmentation and code block CRC attachment are performed according to +- 11 Subclauses 7.2.3 and 5.2.2 of [7]. +- 12 LDPC encoding: Refer to Subclauses 7.2.4 and 5.3.2 in [7] for details. +- 13 Rate matching: Refer to Subclauses 7.2.5 and 5.4.2 in [7] for details. +- 14 CB concatenation: Refer to Subclauses 7.2.6 and 5.5 in [7] for details. +- 15 Scrambling: Refer to Subclause 7.3.1.1 in [6] for details. +- 16 Modulation: Refer to Subclause 7.3.1.2 in [6] for details. +- 17 Layer mapping: Refer to Subclause 7.3.1.3 in [6] for details. +- 18 RE mapping: Refer to Subclause 7.3.1.5 and 7.3.1.6 in [6] for details on Resource Element (RE) mapping. +- 19 The downlink physical layer processing of control channel (PDCCH) carrying Downlink Control Information (DCI) +- 20 consists of the following steps: +- 21 CRC attachment: Error detection is provided on DCI transmissions through a Cyclic Redundancy Check (CRC). Refer +- 22 to Subclause 7.3.2 in [7] for details. +- 23 Polar encoding: Refer to Subclauses 7.3.3 and 5.3.1 in [7] for details. +- 24 Rate matching: Refer to Subclauses 7.3.4 and 5.4.1 in [7] for details. +- 25 Scrambling: Refer to Subclause 7.3.2.3 in [6] for details. +- 26 Modulation: Refer to Subclause 7.3.2.4 in [6] for details. +- 27 RE mapping: Refer to Subclause 7.3.2.5 in [6] for details. +- 28 The downlink physical layer processing of broadcast channel (PBCH) carrying maximum one transport block consists +- 29 of the following steps: +- 30 PBCH payload generation: Refer to Subclause 7.1.1 in [7] for details. +- 31 Scrambling: Refer to Subclause 7.1.2 in [7] for details. +- 32 TB CRC attachment: Refer to Subclause 7.1.3 in [7] for details. +- 33 Polar encoding: Refer to Subclauses 7.1.4 and 5.3.1 in [7] for details. +- 34 Rate matching: Refer to Subclauses 7.1.5 and 5.4.1 in [7] for details. +- 35 Data scrambling: Refer to Subclause 7.3.3.1 in [6] for details. +- 36 Modulation: Refer to Subclause 7.3.3.2 in [6] for details. +- 37 RE mapping: Refer to Subclause 7.3.3.3 in [6] for details. + +The downlink physical signals (DM-RS, PSS, SSS, CSI-RS/TRS, PT-RS) correspond to a set of resource elements used by the physical layer but does not carry information originated from higher layers (i.e. layer 2 and above). + +Reference Signals (DM-RS, CSI-RS/TRS, PT-RS) and Synchronization Signals (PSS/SSS) are generated using the following steps: + +Sequence Generation and Modulation: Refer to Subclauses 7.4.1.1.1 (PDSCH DM-RS), 7.4.1.3.1 (PDCCH DM-RS), 7.4.1.4.1 (PBCH DM-RS), 7.4.1.5.2 (CSI-RS/TRS), 7.4.1.2.1 (PT-RS), 7.4.2.2.1 (PSS) and 7.4.2.3.1 (SSS) in [6] for details. + +RE mapping: Refer to Subclauses 7.4.1.1.2 (PDSCH DM-RS), 7.4.1.3.2 (PDCCH DM-RS), 7.4.1.4.2 (PBCH DM-RS), 7.4.1.5.3 (CSI-RS/TRS), 7.4.1.2.2 (PT-RS), 7.4.2.2.2 (PSS) and 7.4.2.3.2 (SSS) in [6] for details. + +An O-DU AAL profile for 5G NR downlink shall specify a set of accelerated functions corresponding to one or more than one physical downlink channel(s) and/or physical downlink signal(s). + +In addition to the processing blocks mentioned above, each of these downlink physical channels/signals may include some additional functional blocks (e.g. precoding, IQ compression) which are implementation specific and may also depend on system configurations/capabilities (for example, whether a O-DU is connected to a CAT-A/CAT-B O-RU). Each of these physical channels/signals can be implemented with/without these optional functional blocks. The AAL Application interface shall expose to the AAL Application whether these functional blocks are supported or not within the AAL Implementation. + +Figure 7.1.1-2: illustrates the building blocks for processing various O-DU PHY layer Uplink (UL) channels and signals (with 7.2-x functional split between O-DU and O-RU) defined by 3GPP [6] as part of 5G NR specification. + +![Figure 7.1.1-2: O-DU PHY processing blocks for 5G NR Uplink. The diagram shows a block diagram of the O-DU PHY layer processing blocks for 5G NR Uplink. It is organized into columns for different channels: PUSCH UL data, PUCCH format 2/3/4 UCI, PUCCH format 1 UCI, PUCCH format 0 UCI, PRACH, SRS, and PT-RS. The blocks are arranged in a grid, with some blocks shared across multiple channels. The top row is labeled 'L2+' and the bottom row is labeled 'O-RAN FH (7-2x lower layer split)'. The blocks include TB CRC check, CB CRC + CB Desegmentation, LDPC decoding, Rate dematching, CB Deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE demapping, IQ decompression*, CRC check, Polar/Block decoding, Rate dematching, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE demapping, IQ decompression*, Preamble detection + delay estimation, Peak search, Noise estimation, IFFT, Root sequence correlation, Channel estimation, RE demapping, IQ decompression*, Sequence detection, RE demapping, IQ decompression*, and RE demapping.](07139cef2d9a17d38eb1c4ef9300ae2a_img.jpg) + +| L2 + | | | | | | | +|-----------------------------------|--|-----------------------------------|--|---------------------------------------|--|--| +| <b>PUSCH<br/>UL data</b> | | <b>PUCCH format 2/3/4<br/>UCI</b> | | <b>PRACH</b> | | | +| TB CRC check | | CRC check | | Preamble detection + delay estimation | | | +| CB CRC + CB Desegmentation | | Polar/Block decoding | | Peak search | | | +| LDPC decoding | | Rate dematching | | Noise estimation | | | +| Rate dematching | | Descrambling | | IFFT | | | +| CB Deconcatenation | | Demodulation | | Root sequence correlation | | | +| Descrambling | | IDFT for DFT-s-OFDM | | Channel estimation | | | +| Demodulation | | Channel equalization | | RE demapping | | | +| IDFT for DFT-s-OFDM | | Channel estimation | | IQ decompression* | | | +| Channel equalization | | RE demapping | | | | | +| Channel estimation | | IQ decompression* | | | | | +| RE demapping | | | | | | | +| IQ decompression* | | | | | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | + +Figure 7.1.1-2: O-DU PHY processing blocks for 5G NR Uplink. The diagram shows a block diagram of the O-DU PHY layer processing blocks for 5G NR Uplink. It is organized into columns for different channels: PUSCH UL data, PUCCH format 2/3/4 UCI, PUCCH format 1 UCI, PUCCH format 0 UCI, PRACH, SRS, and PT-RS. The blocks are arranged in a grid, with some blocks shared across multiple channels. The top row is labeled 'L2+' and the bottom row is labeled 'O-RAN FH (7-2x lower layer split)'. The blocks include TB CRC check, CB CRC + CB Desegmentation, LDPC decoding, Rate dematching, CB Deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE demapping, IQ decompression\*, CRC check, Polar/Block decoding, Rate dematching, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE demapping, IQ decompression\*, Preamble detection + delay estimation, Peak search, Noise estimation, IFFT, Root sequence correlation, Channel estimation, RE demapping, IQ decompression\*, Sequence detection, RE demapping, IQ decompression\*, and RE demapping. + +**Figure 7.1.1-2: O-DU PHY processing blocks for 5G NR Uplink** + +The O-DU PHY layer in uplink consists of the following physical channels and reference signals: + +- Physical Uplink Shared Channel (PUSCH). +- Physical Uplink Control Channels (PUCCH) with formats 0/1/2/3/4. +- Physical Random-Access Channel (PRACH). + +- Sounding Reference Signal (SRS). + - Phase Tracking Reference Signal (PT-RS) for UL. +- The uplink physical channels (PUSCH, PUCCH, PRACH) carry information originating from higher layers (i.e. layer 2 and above). +- The uplink physical layer processing of shared channel (PUSCH) carrying uplink data with or without Uplink Control Information (UCI) consists of the following steps at the receiver (O-DU): +- RE de-mapping: Refer to Subclauses 6.3.1.6, 6.3.1.7 and 6.4.1.1.3 of [6] for details on RE mapping at the transmitter. + - Channel estimation and equalization: up to O-DU implementation. + - Transform precoding (IDFT): optional, only required for DFT-s-OFDM waveform. Refer to Subclause 6.3.1.4 of [6] for details on transform precoding (if applicable) applied at the transmitter. + - Demodulation: Refer to Subclause 6.3.1.2 in [6] for details on modulation applied at the transmitter. + - Descrambling: Refer to Subclause 6.3.1.1 in [6] for details on scrambling applied at the transmitter. + - CB de-concatenation: Refer to Subclause 6.2.6 in [7] for details on CB concatenation applied at the transmitter. + - Rate de-matching: Refer to Subclause 6.2.5 in [7] for details on rate matching applied at the transmitter. + - LDPC decoding: Refer to Subclause 6.2.4 in [7] for details on LDPC encoding applied at the transmitter. + - CB de-segmentation and CB CRC check: Refer to Subclause 6.2.3 in [7] for details on CB segmentation and CB CRC attachment applied at the transmitter. + - TB CRC check: Refer to Subclause 6.2.1 in [7] for details on TB level CRC attachments applied at the transmitter. +- The uplink physical layer processing for control channel (PUCCH) carrying UCI depends on PUCCH formats. +- PUCCH format 0 processing consists of the following steps at the receiver (O-DU): +- RE de-mapping: Refer to subclause 6.3.2.3.2 of [6] for details on RE mapping applied at the transmitter. + - Sequence detection: The transmitted sequence (refer to Subclause 6.3.2.3 in [6] for details) is detected at O-DU using a non-coherent detector, since PUCCH format 0 does not carry any DM-RS. The detailed design is up to O-DU implementation. +- PUCCH format 1 processing consists of the following steps at the receiver (O-DU): +- RE de-mapping: Refer to Subclauses 6.3.2.4.2 and 6.4.1.3.1.2 of [6] for details on RE mapping applied at the transmitter. + - Channel estimation and equalization: up to O-DU implementation. + - Demodulation: Refer to Subclause 6.3.2.4.1 in [6] for details on modulation applied at the transmitter. +- PUCCH formats 2/3/4 processing consists of the following steps at the receiver (O-DU): +- RE de-mapping: Refer to Subclauses 6.3.2.5.3 and 6.4.1.3.2.2 (format 2); 6.3.2.6.5 and 6.4.1.3.3.2 (formats 3/4) of [6] for details on RE mapping applied at the transmitter. + - Channel estimation and equalization: up to O-DU implementation. + - Transform precoding (IDFT): optional, only required for DFT-s-OFDM waveform. Refer to Subclause 6.3.2.6.4 of [6] for details on transform precoding (applicable for formats 3/4) applied at the transmitter. + - Demodulation: Refer to Subclause 6.3.2.5.2 (format 2) and 6.3.2.6.2 (formats 3/4) in [6] for details on modulation applied at the transmitter. + - Descrambling: Refer to Subclause 6.3.2.5.1 (format 2) and 6.3.2.6.1 (formats 3/4) in [6] for details on scrambling applied at the transmitter. + +- 1 Rate de-matching: Refer to Subclause 6.3.1.4 in [7] for details on rate matching applied at the transmitter. +- 2 Polar/Block decoding: Refer to Subclause 6.3.1.3 in [7] for details on Polar/Block encoding applied at the transmitter. +- 3 CRC check: Refer to Subclause 6.3.1.2 in [7] for details on CRC attachment applied at the transmitter. +- 4 The uplink physical layer processing for random access channel (PRACH) carrying preamble consists of the following +- 5 steps at the receiver (O-DU): +- 6 RE de-mapping: Refer to Subclause 6.3.3.2 in [6] for details on RE mapping applied at the transmitter. +- 7 Root sequence correlation: Perform correlation operation between root sequence and received signals. Refer to +- 8 Subclause 6.3.3.1 in [6] for details on root sequence generation. +- 9 IFFT: perform the inverse Fast Fourier Transform (iFFT) operation on the received signal(s). +- 10 Noise estimation: perform the noise estimation operation. +- 11 Peak search: detect the peak for different root sequences. +- 12 Preamble detection and Timing Advance (TA) or delay estimation: determine the preamble sequence(s) received and +- 13 the corresponding timing advance estimate(s). +- 14 The uplink physical signals (SRS, PT-RS) do not carry any information from the higher layers (i.e. layer 2 and above). +- 15 The Sounding Reference Signal (SRS) in uplink is received at O-DU using the following steps: +- 16 RE de-mapping: Refer to Subclauses 6.4.1.4.3 and 6.4.1.4.4 in [6] for details on RE mapping applied at the transmitter. +- 17 Sequence detection and Channel estimation: Up to O-DU implementation. Refer to 6.4.1.4.2 in [6] for details on SRS +- 18 sequence generation at the transmitter. Channel condition in uplink is estimated at the O-DU based on the processing of +- 19 received SRS. +- 20 The Phase-Tracking Reference Signal (PT-RS) in uplink is received at the O-DU using the following steps: +- 21 RE de-mapping: Refer to Subclause 6.4.1.2.2 in [6] for details on RE mapping applied at the transmitter. +- 22 Sequence detection: Up to O-DU implementation. Refer to Subclause 6.4.1.2.1 in [6] for details on sequence generation +- 23 at the transmitter. +- 24 An O-DU AAL profile for 5G NR uplink shall specify a set of accelerated functions corresponding to one or more than +- 25 one physical uplink channel(s) and/or physical uplink signal(s). +- 26 In addition to the processing blocks mentioned above, each of these uplink physical channels/signals may include an +- 27 additional functional block, viz. IQ decompression, which is implementation specific and may depend on system +- 28 configuration/capability. Each of these physical channels/signals can be implemented with/without this optional +- 29 functional block. The AAL Application interface shall expose to the AAL Application whether these functional blocks +- 30 are supported or not within the AAL Implementation. + +###### 31 7.1.2 O-DU Protocol Stack Reference for mMTC + +32 Figure 7.1.2-1 illustrates the building blocks for processing various O-DU PHY layer Downlink (DL) channels and +33 signals (with 7.2-x functional split between O-DU and O-RU) defined by 3GPP in [8] & [9] as part of 4G/5G NR +34 specification. + +![](326f0dd17e7270c9eb44cc0d9d00c9ca_img.jpg) + +| L2+ | | | | | +|-----------------------------------|----------------------------------|----------------------------------|----------------------|---------------------| +| <b>NPDSCH TB(s)</b> | | <b>NPBCH TB</b> | | | +| TB CRC attachment | | PBCH payload generation | | | +| Tail Biting Convolutional Coding | | CRC attachment | | | +| | <b>N PDCCH (DCI)</b> | Tail Biting Convolutional Coding | | | +| Rate matching | CRC attachment | Rate Matching | | | +| CB concatenation | Tail Biting Convolutional Coding | Scrambling | <b>NPSS/NSSS/NRS</b> | <b>NPRS/NWUS</b> | +| Scrambling | Rate matching | Modulation | Sequence Generation | Sequence Generation | +| Modulation | Scrambling | Layer Mapping | Modulation | Modulation | +| Layer mapping | Modulation (QPSK) | | | | +| Precoding* | Precoding* | Precoding* | | Precoding* | +| RE mapping | RE mapping | RE mapping | | RE mapping | +| IQ compression* | IQ compression* | IQ compression* | | IQ compression* | +| O-RAN FH (7-2x lower layer split) | | | | | + +**Figure 7.1.2-1: O-DU PHY processing blocks for mMTC Downlink.** + +The O-DU PHY layer in downlink consists of the following physical channels and reference signals: + +- Narrow-band Physical Downlink Shared Channel (NPDSCH). +- Narrow-band Physical Downlink Control Channel (NPDCCH). +- Narrow-band Physical Broadcast Channel (NPBCH). +- Narrow-band Primary Synchronization Signal (NPSS). +- Narrow-band Secondary Synchronization Signal (NSSS). +- Narrow-band Reference Signal (NRS) and Narrow-band Position Reference Signal (NPRS). +- Narrow-band Wake-Up Signal (NWUS) + +The Narrow-band downlink physical channels (NPDSCH, NPDCCH, NPBCH) carry information originating from higher layers (i.e. layer 2 and above). + +The Narrow-band downlink physical layer processing of data channel (NPDSCH) carrying transport blocks consists of the following steps: + +**TB CRC attachment:** Error detection is provided on each transport block (TB) through a Cyclic Redundancy Check (CRC). Refer to Subclause 6.4 in [9] for details. + +**CRC attachment:** CRC attachment is performed according to Subclauses 6.4 of [9] + +- 1 Tail-biting Convolutional coding: Refer to Subclauses 6.2 and 5.1.3.1 in [9] for details. +- 2 Rate matching: Refer to Subclauses 6.4 in [9] for details. +- 3 Scrambling: Refer to Subclause 10.2.5.2 in [8] for details. +- 4 Modulation: Refer to Subclause 10.2.5.3 in [8] for details. +- 5 Layer mapping: Refer to Subclause 10.2.5.3 in [8] for details. +- 6 RE mapping: Refer to Subclause 10.2.5.5 in [8] for details on Resource Element (RE) mapping. +- 7 The downlink physical layer processing of control channel (PDCCH) carrying Downlink Control Information (DCI) +- 8 consists of the following steps: +- 9 CRC attachment: Error detection is provided on DCI transmissions through a Cyclic Redundancy Check (CRC). Refer +- 10 to Subclause 6.4 in [9] for details. +- 11 Tail-biting Convolutional coding: Refer to Subclauses 6.2 and 5.1.3.1 in [9] for details. +- 12 Scrambling: Refer to Subclause 10.2.5.2 in [8] for details. +- 13 Modulation: Refer to Subclause 10.2.5.3 in [8] for details. +- 14 Layer mapping: Refer to Subclause 10.2.5.3 in [8] for details. +- 15 RE mapping: Refer to Subclause 10.2.5.5 in [8] for details on Resource Element (RE) mapping. +- 16 The downlink physical layer processing of broadcast channel (NPBCH) carrying maximum one transport block consists +- 17 of the following steps: +- 18 NPBCH payload generation: Refer to Subclause 6.4.1 in [9] for details. +- 19 TB CRC attachment: Error detection is provided on each transport block (TB) through a Cyclic Redundancy Check +- 20 (CRC). Refer to Subclause 6.4 in [9] for details. +- 21 Scrambling: Refer to Subclause 10.2.5.2 in [8] for details. +- 22 Modulation: Refer to Subclause 10.2.5.3 in [8] for details. +- 23 Layer mapping: Refer to Subclause 10.2.5.3 in [8] for details. +- 24 RE mapping: Refer to Subclause 10.2.5.5 in [8] for details on Resource Element (RE) mapping. +- 25 The downlink physical signals (NRS, NPSS, NSSS, NPRS, NWUS) correspond to a set of resource elements used by +- 26 the physical layer but does not carry information originated from higher layers (i.e., layer 2 and above). +- 27 Reference Signals and Synchronization signals (NPSS/NSSS) are generated using the following steps: +- 28 Sequence Generation and Modulation and RE mapping: Refer to Subclauses, 10.2.6B (NWUS), 10.2.7.1 (NPSS) and +- 29 10.2.7.2 (NSSS), 10.2.6 (NRS), 10.2.6A (NPRS) in [8] for details. +- 30 An O-DU AAL profile for 4G NR downlink shall specify a set of accelerated functions corresponding to one or more +- 31 than one physical downlink channel(s) and/or physical downlink signal(s). +- 32 In addition to the processing blocks mentioned above, each of these downlink physical channels/signals may include +- 33 some additional functional blocks (e.g., precoding, IQ compression) which are implementation specific and may also +- 34 depend on system configurations/capabilities (for example, whether a O-DU is connected to a CAT-A/CAT-B O-RU). +- 35 Each of these physical channels/signals can be implemented with/without these optional functional blocks. The AAL +- 36 Application interface shall expose to the AAL Application whether these functional blocks are supported or not within +- 37 the AAL Implementation. +- 38 Figure 7.1.2-2 illustrates the building blocks for processing various O-DU PHY layer Uplink (UL) channels and signals +- 39 (with 7.2-x functional split between O-DU and O-RU) defined by 3GPP in [8] & [9] as part of 4G/5G NR specification. + +O-RAN.WG6.AAL-GAnP-R004-v10.00 + +![O-RAN Alliance Logo](2403fd122a020f4cfa8685977be482ac_img.jpg) +![Figure 7.1.2-2: O-DU PHY processing blocks for mMTC Uplink](c5ceeaba522967d2ca66967f4aa00a6f_img.jpg) + +Detailed description of the diagram: The diagram shows the O-DU PHY processing blocks for mMTC Uplink, split between L2+ and O-RAN FH (7-2x lower layer split). It consists of four main processing paths from right to left: + +- NPRACH:** IQ decompression\* -> RE demapping -> Root sequence correlation -> IFFT -> Noise estimation -> Peak search -> Preamble detection + delay estimation. +- PUSCH Format 2 UCI:** IQ decompression\* -> RE demapping -> Channel estimation -> Channel equalization -> Demodulation -> Descrambling -> Rate dematching -> Channel decoding -> AC-NACK detection. +- DMRS with PUSCH Format 1 and Format 2:** IQ decompression\* -> RE demapping -> Channel Estimation. +- NPUSCH UL data:** IQ decompression\* -> RE demapping -> Channel estimation -> Channel equalization -> IDFT for DFT-s-OFDM -> Layer Demapping -> Demodulation -> Descrambling -> Rate dematching -> Turbo decoding -> CRC check. + +All paths start from the O-RAN FH (7-2x lower layer split) at the bottom and end at the L2+ layer at the top. Asterisks (\*) indicate optional IQ decompression. + +Figure 7.1.2-2: O-DU PHY processing blocks for mMTC Uplink + +**Figure 7.1.2-2: O-DU PHY processing blocks for mMTC Uplink** + +The O-DU PHY layer in uplink consists of the following physical channels and reference signals: + +- Narrow-band Physical Uplink Shared Channel (NPUSCH). +- Narrow-band Physical Random-Access Channel (NPRACH). + +The uplink physical channels (NPUSCH, NPRACH) carry information originating from higher layers (i.e., layer 2 and above). + +The uplink physical layer processing of shared channel (NPUSCH) carrying uplink data with or without Uplink Control Information (UCI) consists of the following steps at the receiver (O-DU): + +RE (de)mapping: Refer to Subclauses 5.3.4 of [8] for details on RE mapping at the transmitter/receiver. + +Channel estimation and equalization: up to O-DU implementation. + +Transform precoding (IDFT): optional, only required for DFT-s-OFDM waveform. Refer to Subclause 5.3.3A of [8] for details on transform precoding (if applicable) applied at the transmitter. + +Demodulation: Refer to Subclause 5.3.2 in [8] for details on modulation applied at the transmitter. + +Descrambling: Refer to Subclause 5.3.1 in [8] for details on scrambling applied at the transmitter. + +Rate de-matching: Refer to Subclause 5.1.4.1 in [9] for details on rate matching applied at the transmitter. + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 45 + +Turbo decoding: Refer to Subclause 5.1.3.2 in [9] for details on Turbo decoding applied at the transmitter. + +CRC check: Refer to Subclauses 5.1.1 in [9] for details on TB and CB level CRC attachments applied at the transmitter. + +The uplink physical layer processing for shared channel (NPUSCH) carrying UCI depends on NPUSCH formats. + +An O-DU AAL profile for 4G/5G NR uplink shall specify a set of accelerated functions corresponding to one or more than one physical uplink channel(s) and/or physical uplink signal(s). + +In addition to the processing blocks mentioned above, each of these uplink physical channels/signals may include an additional functional block, viz. IQ decompression, which is implementation specific and may depend on system configuration/capability. Each of these physical channels/signals can be implemented with/without this optional functional block. The AAL Application interface shall expose to the AAL Application whether these functional blocks are supported or not within the AAL Implementation. + +### 7.1.3 O-DU AAL Profile Definitions + +O-DU AAL profiles are defined below with future specification(s) to define the AAL Application interface for each profile. + +#### 7.1.3.1 Profile Definitions General Guidelines + +##### 7.1.3.1.1 Naming + +As discussed above O-DU AAL profiles are specific to one or more physical channel(s) or signal(s) as such should follow the naming guidelines + +- O-DU AAL profiles shall be prefixed with “AAL\_” +- O-DU AAL profiles when specific to a single channel or signal shall include the channel or signal in the name e.g. “AAL\_PUSCH” +- O-DU AAL profiles when common across multiple channels or signals shall not include the channel or signal name, instead just reference the Accelerated Function(s), e.g. AAL\_RE-MAPPING +- O-DU AAL profiles that include a subset of the functional blocks within a channel or signal shall include a functional description after the channel name e.g. AAL\_PUSCH\_CHANNEL\_ESTIMATION + +##### 7.1.3.1.2 Data Flow + +O-DU AAL profiles shall specify the data flow supported by the AAL Profile. + +Look aside data flow implies the remaining functions not included in the Profile that comprise the channel or signal are implemented on the AAL Application or other entity associated with the AAL Application and not implemented in the HW Accelerator. + +Inline data flow implies that the signal (with a 7-2x PHY functional split) and the IQ data from the AAL Application (in DL) or the decoded bits (in UL) (post processing) are transferred directly from the HW Accelerator to the Fronthaul interface (in DL) or to the AAL Application (in UL). + +The profile shall specify if the data flow includes only user plane, or only control plane, or both. + +#### 7.1.3.2 O-DU AAL Profiles + +##### 7.1.3.2.1 AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC + +![Figure 7.1.3.2.1-1: AAL_MU-MIMO_PRECODER_WEIGHTS_CALC. A block diagram showing the flow of data through various processing blocks. The top section, labeled L2, contains four stacked blocks: 'User Grouping and Scheduling', 'Precoder/BF Weights Calculation' (highlighted in yellow), 'Link Adaptation, MCS selection', and 'TB Formation and associated control information'. A horizontal line separates this from the bottom section, labeled L1, which contains a single block 'High Phy'. Arrows indicate the flow from top to bottom.](dc7e43fd179403deae0d9a1153aa8fa9_img.jpg) + +Figure 7.1.3.2.1-1: AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC. A block diagram showing the flow of data through various processing blocks. The top section, labeled L2, contains four stacked blocks: 'User Grouping and Scheduling', 'Precoder/BF Weights Calculation' (highlighted in yellow), 'Link Adaptation, MCS selection', and 'TB Formation and associated control information'. A horizontal line separates this from the bottom section, labeled L1, which contains a single block 'High Phy'. Arrows indicate the flow from top to bottom. + +**Figure 7.1.3.2.1-1: AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC** + +The AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC is used by AAL Application to offload beamforming (precoding) weight calculation to the hardware accelerator (HWA) in look-aside acceleration mode. The AAL Application shall provide HWA with all the information required to calculate precoding weights. + +This profile is implemented as a look aside accelerator. + +The below figure shows an example use of the AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC in an O-DU with AAL\_DOWNLINK\_HIGH-PHY and AAL\_UPLINK\_HIGH-PHY + +![Figure 7.1.3.2.1-2: Example AAL_MU-MIMO_PRECODER_WEIGHTS_CALC use. A block diagram showing the interaction between the GPP/CPU and the HW Accelerator. The GPP/CPU contains an 'AAL Application' block. The HW Accelerator contains two blocks: 'Precoder/BF Weights Calculation Function' and 'High PHY Profile'. Arrows show data flow: a red arrow from AAL Application to Precoder/BF Weights Calculation Function (labeled 'Look-aside AAL Profile for precoder calculation'), a black arrow from Precoder/BF Weights Calculation Function to AAL Application, a red arrow from AAL Application to High PHY Profile (labeled 'Inline High Phy AAL Profile for slot level data path procedure'), and a black arrow from High PHY Profile to AAL Application. A black arrow points down from the HW Accelerator block.](1d4d26b60f5f4b2cd299137d518379ff_img.jpg) + +Figure 7.1.3.2.1-2: Example AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC use. A block diagram showing the interaction between the GPP/CPU and the HW Accelerator. The GPP/CPU contains an 'AAL Application' block. The HW Accelerator contains two blocks: 'Precoder/BF Weights Calculation Function' and 'High PHY Profile'. Arrows show data flow: a red arrow from AAL Application to Precoder/BF Weights Calculation Function (labeled 'Look-aside AAL Profile for precoder calculation'), a black arrow from Precoder/BF Weights Calculation Function to AAL Application, a red arrow from AAL Application to High PHY Profile (labeled 'Inline High Phy AAL Profile for slot level data path procedure'), and a black arrow from High PHY Profile to AAL Application. A black arrow points down from the HW Accelerator block. + +**Figure 7.1.3.2.1-2: Example AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC use.** + +Image: O-RAN Alliance Logo + +O-RAN.WG6.AAL-GANP-R004-v10.00 + +### 7.1.3.2.2 AAL\_FFT + +![Figure 7.1.3.2.2-1: AAL_FFT block diagram showing the processing chain for PUSCH, PUCCH, PRACH, SRS, and PT-RS, highlighting the IDFT/DFT and IFFT blocks as accelerated functions.](c625e8aa036cd7ab94572cb68c6e0e9e_img.jpg) + +The diagram illustrates the uplink physical layer processing blocks from the O-RAN FH (7-2x lower layer split) up to L2+. It shows the following processing chains from bottom to top: + +- PUSCH UL data:** IQ decompression\* → RE demapping → Channel estimation → Channel equalization → IDFT for DFT-s-OFDM → Demodulation → Descrambling → CB deconcatenation → Rate dematching → LDPC decoding → CB CRC + CB desegmentation → TB CRC check → L2+. +- PUCCH format 0 UCI:** IQ decompression\* → RE demapping → Sequence detection → L2+. +- PUCCH format 1 UCI:** IQ decompression\* → RE demapping → Channel estimation → Channel equalization → Demodulation → L2+. +- PUCCH format 2/3/4 UCI:** IQ decompression\* → RE demapping → Channel estimation → Channel equalization → IDFT for DFT-s-OFDM → Demodulation → Descrambling → Rate dematching → Polar/Block decoding → CRC check → L2+. +- PRACH:** IQ decompression\* → RE demapping → Root sequence correlation → IFFT → Noise estimation → Peak search → Preamble detection + delay estimation → L2+. +- SRS:** IQ decompression\* → RE demapping → Channel estimation → L2+. +- PT-RS:** IQ decompression\* → RE demapping → Sequence detection → L2+. + +Note: Highlighted blocks (IDFT for DFT-s-OFDM, IFFT, and Channel estimation) represent the accelerated functions defining the AAL\_FFT Profile. + +Figure 7.1.3.2.2-1: AAL\_FFT block diagram showing the processing chain for PUSCH, PUCCH, PRACH, SRS, and PT-RS, highlighting the IDFT/DFT and IFFT blocks as accelerated functions. + +**Figure 7.1.3.2.2-1: AAL\_FFT** + +The AAL\_FFT is used by application to offload FFT/iFFT processing to the hardware accelerator (HWA) in look-aside acceleration mode. The application shall provide HW Accelerator with all the information required to perform the FFT operations. The AAL\_FFT Profile can be used for 3GPP specification 38.211 clause 5.3, and clause 6.4.1.4. The below list and Figure 7.1.3.2.2-1: AAL\_FFT highlights the set of accelerated functions that define the AAL\_FFT Profile. + +- Zero Padding +- iDFT +- Windowing +- DFT +- De padding + +The below figure shows an example use of the AAL\_FFT Profile for accelerating the SRS processing in an O-DU. The highlighted blocks show the set the accelerated functions. + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. + +48 + +![Figure 7.1.3.2.2-2: AAL_FFT example for SRS Processing. The diagram shows a flow of processing blocks. On the left, a vertical stack of blocks: 'Zadoff-Chu, RB/Comb Extraction' (white), 'Zero Padding' (yellow), 'iDFT' (yellow), 'Ncs Windowing' (white), 'Ncs DFT' (yellow), 'Depadding' (yellow), and 'Timing error correcton, SNR Estimation etc..' (white). On the right, a vertical stack: 'L2 +' (grey), 'SRS Channel estimation' (yellow), 'RE demapping' (white), 'IQ decompression*' (dashed border), and 'O-RAN FH (7-2x lower layer split)' (grey). Two lines connect the left stack to the right stack: one from 'Zadoff-Chu, RB/Comb Extraction' to 'SRS Channel estimation', and another from 'Timing error correcton, SNR Estimation etc..' to 'RE demapping'.](c6277da117aa05cd11899f48d3b70cb9_img.jpg) + +Figure 7.1.3.2.2-2: AAL\_FFT example for SRS Processing. The diagram shows a flow of processing blocks. On the left, a vertical stack of blocks: 'Zadoff-Chu, RB/Comb Extraction' (white), 'Zero Padding' (yellow), 'iDFT' (yellow), 'Ncs Windowing' (white), 'Ncs DFT' (yellow), 'Depadding' (yellow), and 'Timing error correcton, SNR Estimation etc..' (white). On the right, a vertical stack: 'L2 +' (grey), 'SRS Channel estimation' (yellow), 'RE demapping' (white), 'IQ decompression\*' (dashed border), and 'O-RAN FH (7-2x lower layer split)' (grey). Two lines connect the left stack to the right stack: one from 'Zadoff-Chu, RB/Comb Extraction' to 'SRS Channel estimation', and another from 'Timing error correcton, SNR Estimation etc..' to 'RE demapping'. + +**Figure 7.1.3.2.2-2: AAL\_FFT example for SRS Processing** + +This profile is implemented as a look aside accelerator. + +#### 7.1.3.3 O-DU AAL Profiles for Downlink + +##### 7.1.3.3.1 AAL\_PDSCH\_FEC + +Figure 7.1.3.3.1-1 highlights the set of accelerated functions that define the AAL\_PDSCH\_FEC Profile. These include: + +- CRC Generation +- LDPC Encoding +- PDSCH Rate Matching + +The AAL\_PDSCH\_FEC Profile is implemented as a look aside accelerator. The AAL\_PDSCH\_FEC Profile will support both Transport Block and Code Block operations. + +![Figure 7.1.3.3.1-1: AAL_PDSCH_FEC Profile block diagram showing processing flows for PDSCH TB(s), PDCCH (DCI), PBCH TB, and CSI-RS/PT-RS/TRS.](c9a80d1f8064f6a3e713285481816cf8_img.jpg) + +The diagram illustrates the AAL\_PDSCH\_FEC Profile processing flows. It is organized into four main columns representing different data streams: PDSCH TB(s), PDCCH (DCI), PBCH TB, and CSI-RS/PT-RS/TRS. The flows are as follows: + +- PDSCH TB(s) Column:** TB CRC attachment (highlighted in yellow), CB segmentation + CB CRC attachment (highlighted in yellow), LDPC encoding (highlighted in yellow), Rate matching (highlighted in yellow), CB concatenation, Scrambling, Modulation, Layer mapping, Precoding\* (dashed box), RE mapping, and IQ compression\* (dashed box). +- PDCCH (DCI) Column:** CRC attachment, Polar encoding, Rate matching, Scrambling, Modulation (QPSK), Precoding\* (dashed box), RE mapping, and IQ compression\* (dashed box). +- PBCH TB Column:** PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, Modulation (QPSK), Precoding\* (dashed box), RE mapping, and IQ compression\* (dashed box). +- CSI-RS/PT-RS/TRS Column:** Sequence Generation, Modulation, Precoding\* (dashed box), RE mapping, and IQ compression\* (dashed box). + +Intermediate processing blocks include: + +- PDSCH DM-RS:** Sequence generation, Modulation. +- PDCCH DM-RS:** Sequence generation, Modulation. +- PSS/SSS PBCH DM-RS:** Sequence Generation, Modulation. + +The entire profile is contained within the O-RAN FH (7-2x lower layer split) block. + +Figure 7.1.3.3.1-1: AAL\_PDSCH\_FEC Profile block diagram showing processing flows for PDSCH TB(s), PDCCH (DCI), PBCH TB, and CSI-RS/PT-RS/TRS. + +**Figure 7.1.3.3.1-1: AAL\_PDSCH\_FEC Profile** + +##### 7.1.3.3.2 AAL\_PDSCH\_HIGH-PHY + +Figure 7.1.3.3.2-1 highlights the set of accelerated functions that defines the AAL\_PDSCH\_HIGH-PHY Profile, which includes the processing of PDSCH TB(s) and associated DM-RS. + +The set of accelerated functions associated with the processing of PDSCH TB(s) is as follows: + +- TB CRC attachment +- CB segmentation and CRC attachment +- LDPC encoding +- Rate matching +- CB concatenation +- Scrambling +- Modulation +- Layer mapping +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +<sup>1</sup> Configurable functional block, depends on implementation and/or system configuration + +The set of accelerated functions associated with the processing of PDSCH DM-RS is as follows: + +- PDSCH DM-RS sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The AAL\_PDSCH\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.3.2-1: AAL_PDSCH_HIGH-PHY Profile block diagram showing the flow of data through various processing blocks for PDSCH, PDCCH, PBCH, and CSI-RS/PT-RS/TRS.](2dc0ec8efd870a4610e147658a2eb972_img.jpg) + +The diagram illustrates the AAL\_PDSCH\_HIGH-PHY Profile architecture, showing the flow of data through various processing blocks. The architecture is organized into several main sections: PDSCH TB(s), PDCCH (DCI), PBCH TB, and CSI-RS/PT-RS/TRS. The PDSCH TB(s) section includes TB CRC attachment, CB segmentation + CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. The PDCCH (DCI) section includes CRC attachment, Polar encoding, Rate matching, Scrambling, and Modulation (QPSK). The PBCH TB section includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, and Modulation (QPSK). The CSI-RS/PT-RS/TRS section includes Sequence Generation and Modulation. The diagram also shows the flow of data through various DM-RS (Demodulation Reference Signals) and RS (Reference Signals) blocks, including PDSCH DM-RS, PDCCH DM-RS, PBCH DM-RS, and CSI-RS/PT-RS/TRS. The diagram is divided into two main layers: L2+ (top) and O-RAN FH (7-2x lower layer split) (bottom). The L2+ layer contains the PDSCH TB(s), PDCCH (DCI), PBCH TB, and CSI-RS/PT-RS/TRS blocks. The O-RAN FH layer contains the PDSCH DM-RS, PDCCH DM-RS, PBCH DM-RS, and CSI-RS/PT-RS/TRS blocks. The diagram also shows the flow of data through various DM-RS and RS blocks, including PDSCH DM-RS, PDCCH DM-RS, PBCH DM-RS, and CSI-RS/PT-RS/TRS. The diagram is divided into two main layers: L2+ (top) and O-RAN FH (7-2x lower layer split) (bottom). The L2+ layer contains the PDSCH TB(s), PDCCH (DCI), PBCH TB, and CSI-RS/PT-RS/TRS blocks. The O-RAN FH layer contains the PDSCH DM-RS, PDCCH DM-RS, PBCH DM-RS, and CSI-RS/PT-RS/TRS blocks. + +Figure 7.1.3.3.2-1: AAL\_PDSCH\_HIGH-PHY Profile block diagram showing the flow of data through various processing blocks for PDSCH, PDCCH, PBCH, and CSI-RS/PT-RS/TRS. + +**Figure 7.1.3.3.2-1: AAL\_PDSCH\_HIGH-PHY Profile** + +##### 7.1.3.3.3 AAL\_PDCCH\_HIGH-PHY + +Figure 7.1.3.3.3-1 highlights the set of accelerated functions that defines the AAL\_PDCCH\_HIGH-PHY Profile, which includes the processing of PDCCH DCI and associated DM-RS. + +The set of accelerated functions associated with the processing of PDCCH TB(s) is as follows: + +- CRC attachment +- Polar encoding +- Rate matching +- Scrambling +- Modulation (QPSK) + +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The set of accelerated functions associated with the processing of PDCCH DM-RS is as follows: + +- PDCCH DM-RS sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The AAL\_PDCCH\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.3.3-1: AAL_PDCCH_HIGH-PHY Profile block diagram showing the flow of data through various processing blocks for PDSCH, PDCCH, PBCH, and CSI-RS/PT-RS/TRS.](c8043b53aa69ceb98946fe935191c061_img.jpg) + +The diagram illustrates the AAL\_PDCCH\_HIGH-PHY Profile architecture, showing the flow of data through various processing blocks. The architecture is organized into several main sections: PDSCH TB(s), PDCCH (DCI), PBCH TB, and CSI-RS/PT-RS/TRS. The PDSCH TB(s) section includes TB CRC attachment, CB segmentation + CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. The PDCCH (DCI) section includes CRC attachment, Polar encoding, Rate matching, Scrambling, and Modulation (QPSK). The PBCH TB section includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, Modulation (QPSK), and Precoding\*. The CSI-RS/PT-RS/TRS section includes Sequence Generation, Modulation, and Precoding\*. The diagram also shows the interaction between these sections, with PDSCH DM-RS and PDCCH DM-RS blocks. The entire architecture is supported by O-RAN FH (7-2x lower layer split). + +Figure 7.1.3.3.3-1: AAL\_PDCCH\_HIGH-PHY Profile block diagram showing the flow of data through various processing blocks for PDSCH, PDCCH, PBCH, and CSI-RS/PT-RS/TRS. + +**Figure 7.1.3.3.3-1: AAL\_PDCCH\_HIGH-PHY Profile** + +##### 7.1.3.3.4 AAL\_PBCH\_HIGH-PHY + +Figure 7.1.3.3.4-1 highlights the set of accelerated functions that defines the AAL\_PBCH\_HIGH-PHY Profile, which includes the processing of PBCH TB and associated DM-RS, PSS and SSS, or in other words, the processing of SSB. + +The set of accelerated functions associated with the processing of PBCH TB is as follows: + +- PBCH payload generation +- Scrambling +- TB CRC attachment +- Polar encoding + +- Rate matching +- Data scrambling +- Modulation (QPSK) +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The set of accelerated functions associated with the processing of PBCH DM-RS/PSS/SSS is as follows: + +- PDCCH DM-RS/PSS/SSS sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The AAL\_PBCH\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Block diagram of the AAL_PBCH_HIGH-PHY Profile showing processing flows for PDSCH, PDCCH, PBCH, PSS/SSS, and CSI-RS/PT-RS/TRS.](75176d78f5c6b5ff3567815b4be47932_img.jpg) + +The diagram illustrates the AAL\_PBCH\_HIGH-PHY Profile architecture, showing the processing flows for different channels and signals. The architecture is organized into several main sections: + +- L2+ Layer:** The top layer of the architecture. +- PDSCH TB(s) Processing:** + - TB CRC attachment + - CB segmentation + CB CRC attachment + - LDPC encoding + - Rate matching + - CB concatenation + - Scrambling + - Modulation + - Layer mapping + - Precoding\* (dashed box) + - RE mapping + - IQ compression\* (dashed box) +- PDCCH (DCI) Processing:** + - CRC attachment + - Polar encoding + - Rate matching + - Scrambling + - Modulation (QPSK) + - Precoding\* (dashed box) + - RE mapping + - IQ compression\* (dashed box) +- PDCCH DM-RS Processing:** + - Sequence generation + - Modulation + - Precoding\* (dashed box) + - RE mapping + - IQ compression\* (dashed box) +- PBCH TB Processing:** + - PBCH payload generation + - Scrambling + - TB CRC attachment + - Polar encoding + - Rate matching + - Data scrambling + - Modulation (QPSK) + - Precoding\* (dashed box) + - RE mapping + - IQ compression\* (dashed box) +- PSS/SSS Processing:** + - Sequence Generation + - Modulation + - Precoding\* (dashed box) + - RE mapping + - IQ compression\* (dashed box) +- CSI-RS/PT-RS/TRS Processing:** + - Sequence Generation + - Modulation + - Precoding\* (dashed box) + - RE mapping + - IQ compression\* (dashed box) + +The bottom layer is labeled **O-RAN FH (7-2x lower layer split)**. + +Block diagram of the AAL\_PBCH\_HIGH-PHY Profile showing processing flows for PDSCH, PDCCH, PBCH, PSS/SSS, and CSI-RS/PT-RS/TRS. + +**Figure 7.1.3.3.4-1: AAL\_PBCH\_HIGH-PHY Profile** + +##### 7.1.3.3.5 AAL\_CSI-RS\_HIGH-PHY + +Figure 7.1.3.3.5-1 highlights the set of accelerated functions that defines the AAL\_CSI-RS\_HIGH-PHY Profile, which includes the following: + +- CSI-RS sequence generation + - Modulation + - Precoding<sup>1</sup> + - RE mapping + - IQ compression<sup>1</sup> +- The AAL\_CSI-RS\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.3.5-1: AAL_CSI-RS_HIGH-PHY Profile block diagram showing the flow from L2+ through various processing blocks for PDSCH, PBCH, and PDCCH channels, including DM-RS and CSI-RS/PT-RS/TRS processing.](56a1854e45100e889160ee8cd359bd87_img.jpg) + +The diagram illustrates the AAL\_CSI-RS\_HIGH-PHY Profile architecture. It is organized into several main sections: PDSCH TB(s), PBCH TB, PDCCH (DCI), and CSI-RS/PT-RS/TRS. The PDSCH TB(s) section includes TB CRC attachment, CB segmentation + CB CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. The PBCH TB section includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, and Modulation (QPSK). The PDCCH (DCI) section includes CRC attachment, Polar encoding, Rate matching, Scrambling, and Modulation (QPSK). The CSI-RS/PT-RS/TRS section includes Sequence Generation, Modulation, Precoding\*, RE Mapping, and IQ compression\*. The diagram also shows the flow of DM-RS (PDSCH DM-RS, PDCCH DM-RS, PSS/SSS PBCH DM-RS) and the final output to O-RAN FH (7-2x lower layer split). + +Figure 7.1.3.3.5-1: AAL\_CSI-RS\_HIGH-PHY Profile block diagram showing the flow from L2+ through various processing blocks for PDSCH, PBCH, and PDCCH channels, including DM-RS and CSI-RS/PT-RS/TRS processing. + +Figure 7.1.3.3.5-1: AAL\_CSI-RS\_HIGH-PHY Profile + +##### 7.1.3.3.6 AAL\_PT-RS-DL\_HIGH-PHY + +Figure 7.1.3.3.6-1 highlights the set of accelerated functions that defines the AAL\_PT-RS-DL\_HIGH-PHY Profile, which includes the following: + +- PT-RS sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The AAL\_PT-RS-DL\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.3.6-1: AAL_PT-RS-DL_HIGH-PHY Profile. This block diagram illustrates the processing flow for the AAL_PT-RS-DL_HIGH-PHY profile. It is organized into columns for different channels: PDSCH TB(s), PDCCH (DCI), PBCH TB, PDSCH DM-RS, PDCCH DM-RS, PSS/SSS PBCH DM-RS, and PT-RS-DL. The top layer is labeled 'L2+'. The bottom layer is labeled 'O-RAN FH (7-2x lower layer split)'. The diagram shows the sequence of operations for each channel, including TB CRC attachment, CB segmentation, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, Layer mapping, Precoding*, RE mapping, and IQ compression*. The PT-RS-DL column is highlighted in yellow.](23889e83eca2ca44e726e437ccdd694e_img.jpg) + +Figure 7.1.3.3.6-1: AAL\_PT-RS-DL\_HIGH-PHY Profile. This block diagram illustrates the processing flow for the AAL\_PT-RS-DL\_HIGH-PHY profile. It is organized into columns for different channels: PDSCH TB(s), PDCCH (DCI), PBCH TB, PDSCH DM-RS, PDCCH DM-RS, PSS/SSS PBCH DM-RS, and PT-RS-DL. The top layer is labeled 'L2+'. The bottom layer is labeled 'O-RAN FH (7-2x lower layer split)'. The diagram shows the sequence of operations for each channel, including TB CRC attachment, CB segmentation, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, Layer mapping, Precoding\*, RE mapping, and IQ compression\*. The PT-RS-DL column is highlighted in yellow. + +Figure 7.1.3.3.6-1: AAL\_PT-RS-DL\_HIGH-PHY Profile + +##### 7.1.3.3.7 AAL\_DOWNLINK\_HIGH-PHY + +Figure 7.1.3.3.7-1 highlights the set of accelerated functions that defines the AAL\_DOWNLINK\_HIGH-PHY Profile. This profile includes the aggregation of all the individual downlink channel profiles as follows: + +###### PDSCH + +- **Data:** see list of accelerated functions associated with the processing of PDSCH TB(s), per section 7.1.3.3.2 +- **DM-RS:** see list of accelerated functions associated with the processing of PDSCH DM-RS, per section 7.1.3.3.2. +- **PT-RS:** see list of accelerated functions listed in section 7.1.3.3.6. + +###### PDCCH: + +- **Data:** see list of accelerated functions associated with the processing of PDCCH TB(s), per section 7.1.3.3.3 +- **DM-RS:** see list of accelerated functions associated with the processing of PDCCH DM-RS, per section 7.1.3.3.3 + +###### SSB: + +- **PSS + SSS:** see list of accelerated functions associated with the processing of PSS/SSS, per section 7.1.3.3.4 +- **PBCH DM-RS:** see list of accelerated functions associated with the processing of PBCH DM-RS, per section 7.1.3.3.4 +- **PBCH:** see list of accelerated functions associated with the processing of PBCH TB(s), per section 7.1.3.3.4 + +###### CSI-RS: + +- see list of accelerated functions listed in section 7.1.3.3.5 + +The AAL\_DOWNLINK\_HIGH-PHY Profile is executed in inline acceleration mode. + +![](a2357d8f7ae4edb55383795158062371_img.jpg) + +| L2+ | | | | | | | | +|-----------------------------------|--|---------------------|--|---------------------|--|-------------------------|-------------------------| +| <b>PDSCH TB(s)</b> | | | | <b>PDCCH (DCI)</b> | | <b>PBCH TB</b> | | +| TB CRC attachment | | | | CRC attachment | | PBCH payload generation | | +| CB segmentation + CRC attachment | | | | Polar encoding | | Scrambling | | +| LDPC encoding | | | | Rate matching | | TB CRC attachment | | +| Rate matching | | | | Polar encoding | | Polar encoding | | +| CB concatenation | | | | Rate matching | | Rate matching | | +| Scrambling | | <b>PDSCH DM-RS</b> | | <b>PDCCH DM-RS</b> | | <b>PSS/SSS</b> | <b>CSI-RS/PT-RS/TRS</b> | +| Modulation | | Sequence generation | | Sequence generation | | PBCH DM-RS | Sequence Generation | +| Layer mapping | | Modulation | | Modulation (QPSK) | | Modulation | Modulation | +| Precoding* | | | | | | Precoding* | | +| RE mapping | | | | | | RE Mapping | | +| IQ compression* | | | | | | IQ compression* | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +Figure 7.1.3.3.7-1AAL\_DOWNLINK\_HIGH-PHY Profile + +#### 7.1.3.4 O-DU AAL Profiles for Uplink + +##### 7.1.3.4.1 AAL\_PUSCH\_FEC + +Figure 7.1.3.4.1-1 highlights the set of accelerated functions that define the AAL\_PUSCH\_FEC Profile. These include: + +- PUSCH Rate De-matching +- LDPC Decoder +- CRC Check + +The AAL\_PUSCH\_FEC Profile is implemented as a look aside accelerator. The AAL\_PUSCH\_FEC Profile will support both Transport Block and Code Block operations. + +![](9e2ba5fca0d6a7198cd2c21fef5f469d_img.jpg) + +| L2 + | | | | | | | | +|---------------------------------------|--|--|--|--|--|--|--| +| <b>PUSCH</b> | | | | | | | | +| UL data | | | | | | | | +| TB CRC check | | | | | | | | +| CB CRC + CB desegmentation | | | | | | | | +| LDPC decoding | | | | | | | | +| Rate dematching | | | | | | | | +| CB deconcatenation | | | | | | | | +| Descrambling | | | | | | | | +| Demodulation | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| PUCCH format 0 UCI | | | | | | | | +| Sequence detection | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| PUCCH format 1 UCI | | | | | | | | +| Demodulation | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| PUCCH format 2/3/4 UCI | | | | | | | | +| CRC check | | | | | | | | +| Polar/Block decoding | | | | | | | | +| Rate dematching | | | | | | | | +| Descrambling | | | | | | | | +| Demodulation | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| PRACH | | | | | | | | +| Preamble detection + delay estimation | | | | | | | | +| Peak search | | | | | | | | +| Noise estimation | | | | | | | | +| IFFT | | | | | | | | +| Root sequence correlation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| SRS | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| PT-RS | | | | | | | | +| Sequence detection | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +Figure 7.1.3.4.1-1: AAL\_PUSCH\_FEC Profile + +##### 7.1.3.4.2 AAL\_PUSCH\_HIGH-PHY + +Figure 7.1.3.4.2-1 highlights the set of accelerated functions that defines the AAL\_PUSCH\_HIGH-PHY Profile, which includes the processing of PUSCH data (with or without UCI). + +The set of accelerated functions associated with the processing of PUSCH data is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation +- Channel equalization +- Transform precoding (optional- only required for DFT-s-OFDM waveform) +- Demodulation +- Descrambling +- Rate de-matching +- LDPC decoding +- CRC check + +The AAL\_PUSCH\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.4.2-1: AAL_PUSCH_HIGH-PHY Profile. This block diagram illustrates the processing flow for PUSCH UL data and various PUCCH formats (0, 1, 2/3/4) and PRACH. The flow starts with PUSCH UL data, followed by TB CRC check, CB CRC + CB desegmentation, LDPC decoding, Rate dematching, CB deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE mapping, and IQ decompression*. The PUCCH formats follow similar steps but include UCI processing and different channel estimation methods. PRACH includes preamble detection and peak search. SRS and PT-RS are also shown. The entire process is part of the O-RAN FH (7-2x lower layer split).](2aeb5a9f8f876edd5be4252be81e4831_img.jpg) + +| | | | | | | | | +|-----------------------------------|---------------------------------------|--|--|--|--|--|--| +| L2 + | | | | | | | | +| <b>PUSCH UL data</b> | | | | | | | | +| TB CRC check | | | | | | | | +| CB CRC + CB desegmentation | | | | | | | | +| LDPC decoding | | | | | | | | +| Rate dematching | | | | | | | | +| CB deconcatenation | | | | | | | | +| Descrambling | | | | | | | | +| Demodulation | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE mapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PUCCH format 2/3/4 UCI</b> | | | | | | | | +| | CRC check | | | | | | | +| | Polar/Block decoding | | | | | | | +| | Rate dematching | | | | | | | +| | Descrambling | | | | | | | +| | Demodulation | | | | | | | +| | IDFT for DFT-s-OFDM | | | | | | | +| | Channel equalization | | | | | | | +| | Channel estimation | | | | | | | +| | RE demapping | | | | | | | +| | IQ decompression* | | | | | | | +| <b>PUCCH format 1 UCI</b> | | | | | | | | +| | Demodulation | | | | | | | +| | Channel equalization | | | | | | | +| | Channel estimation | | | | | | | +| | RE demapping | | | | | | | +| | IQ decompression* | | | | | | | +| <b>PUCCH format 0 UCI</b> | | | | | | | | +| | Sequence detection | | | | | | | +| | RE demapping | | | | | | | +| | IQ decompression* | | | | | | | +| <b>PRACH</b> | | | | | | | | +| | Preamble detection + delay estimation | | | | | | | +| | Peak search | | | | | | | +| | Noise estimation | | | | | | | +| | IFFT | | | | | | | +| <b>SRS</b> | | | | | | | | +| | Channel estimation | | | | | | | +| | RE demapping | | | | | | | +| | IQ decompression* | | | | | | | +| <b>PT-RS</b> | | | | | | | | +| | Sequence detection | | | | | | | +| | RE demapping | | | | | | | +| | IQ decompression* | | | | | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +Figure 7.1.3.4.2-1: AAL\_PUSCH\_HIGH-PHY Profile. This block diagram illustrates the processing flow for PUSCH UL data and various PUCCH formats (0, 1, 2/3/4) and PRACH. The flow starts with PUSCH UL data, followed by TB CRC check, CB CRC + CB desegmentation, LDPC decoding, Rate dematching, CB deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE mapping, and IQ decompression\*. The PUCCH formats follow similar steps but include UCI processing and different channel estimation methods. PRACH includes preamble detection and peak search. SRS and PT-RS are also shown. The entire process is part of the O-RAN FH (7-2x lower layer split). + +Figure 7.1.3.4.2-1 : AAL\_PUSCH\_HIGH-PHY Profile + +##### 7.1.3.4.3 AAL\_PUCCH\_HIGH-PHY + +Figure 7.1.3.4.3.1-1, Figure 7.1.3.4.3.2-1 and Figure 7.1.3.4.3.2-1 highlight the set of accelerated functions that defines the AAL\_PUCCH\_HIGH-PHY Profile, which includes the processing of UCI. + +The set of accelerated functions associated with the processing of PUCCH UCI depends on the PUCCH format being configured by the AAL Application. + +###### 7.1.3.4.3.1 PUCCH format 0 + +The set of accelerated functions associated with the processing of PUCCH UCI using PUCCH format 0 is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Sequence detection + +Image: O-RAN Alliance Logo + + O-RAN.WG6.AAL-GaNP-R004-v10.00 +![AAL_PUCCH_HIGH-PHY Profile (PUCCH format 0) block diagram showing processing chains for PUSCH UL data, PUCCH format 0 UCI, PUCCH format 1 UCI, PUCCH format 2/3/4 UCI, PRACH, SRS, and PT-RS above the O-RAN FH (7-2x lower layer split) and L2+ interface.](ab8b21bc2d581ba98f60635edf82390a_img.jpg) + +AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 0) block diagram showing processing chains for PUSCH UL data, PUCCH format 0 UCI, PUCCH format 1 UCI, PUCCH format 2/3/4 UCI, PRACH, SRS, and PT-RS above the O-RAN FH (7-2x lower layer split) and L2+ interface. + +**Figure 7.1.3.4.3.1-1: AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 0)** + +#### 7.1.3.4.3.2 PUCCH format 1 + +The set of accelerated functions associated with the processing of PUCCH UCI using PUCCH format 1 is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation +- Channel equalization +- Demodulation + +--- + +| | | +|---------------------------------------------------------------------------------------------------------------------------|----| +| © 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. | 59 | +|---------------------------------------------------------------------------------------------------------------------------|----| + +**O-RAN** +ALLIANCE + +O-RAN.WG6.AAL-GANP-R004-v10.00 + +![AAL_PUCCH_HIGH-PHY Profile (PUCCH format 1) block diagram](7d2d6fadefd3e228af37ed9e22f71123_img.jpg) + +Detailed description of the diagram: + The diagram shows the processing chains for different physical channels and signals in the uplink (UL): + - L2+ is at the top. + - O-RAN FH (7-2x lower layer split) is at the bottom. + - PUSCH UL data: TB CRC check -> CB CRC + CB Desegmentation -> LDPC decoding -> Rate dematching -> CB Deconcatenation -> Descrambling -> Demodulation -> IDFT for DFT-s-OFDM -> Channel equalization -> Channel estimation -> RE demapping -> IQ decompression\*. + - PUCCH format 0 UCI: Sequence detection -> RE demapping -> IQ decompression\*. + - PUCCH format 1 UCI (highlighted in yellow): Demodulation -> Channel equalization -> Channel estimation -> RE mapping -> IQ decompression\*. + - PUCCH format 2/3/4 UCI: CRC check -> Polar/Block decoding -> Rate dematching -> Descrambling -> Demodulation -> IDFT for DFT-s-OFDM -> Channel equalization -> Channel estimation -> RE demapping -> IQ decompression\*. + - PRACH: Preamble detection + delay estimation -> Peak search -> Noise estimation -> IFFT -> Root sequence correlation -> RE demapping -> IQ decompression\*. + - SRS: Channel estimation -> RE demapping -> IQ decompression\*. + - PT-RS: Sequence detection -> RE demapping -> IQ decompression\*. + +AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 1) block diagram + +**Figure 7.1.3.4.3.2-1: AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 1)** + +**7.1.3.4.3.3 PUCCH format 2/3/4** + +The set of accelerated functions associated with the processing of PUCCH UCI using PUCCH format 2/3/4 is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation +- Channel equalization +- Transform precoding (optional- only required for DFT-s-OFDM waveform) +- Demodulation +- Descrambling +- Rate de-matching +- Polar/Block decoding +- CRC check + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. + +60 + +Image: O-RAN Alliance Logo + +O-RAN.WG6.AAL-GAnP-R004-v10.00 + +![AAL_PUCCH_HIGH-PHY Profile (PUCCH format 2/3/4)](71dd1f405065aa0bc414f99fcb02ce7d_img.jpg) + +Detailed description of the diagram: + +The diagram illustrates the High-PHY processing blocks and their mapping to the O-RAN FH (7-2x lower layer split) and L2+ interface. It shows several parallel processing paths for different physical channels/signals: + +- PUSCH UL data:** IQ decompression\* → RE demapping → Channel estimation → Channel equalization → IDFT for DFT-s-OFDM → Demodulation → Descrambling → CB Deconcatenation → Rate dematching → LDPC decoding → CB CRC + CB Desegmentation → TB CRC check → L2+ +- PUCCH format 0 UCI:** IQ decompression\* → RE demapping → Sequence detection → L2+ +- PUCCH format 1 UCI:** IQ decompression\* → RE demapping → Channel estimation → Channel equalization → Demodulation → L2+ +- PUCCH format 2/3/4 UCI:** IQ decompression\* → RE mapping → Channel estimation → Channel equalization → IDFT for DFT-s-OFDM → Demodulation → Descrambling → Rate dematching → Polar/Block decoding → CRC check → L2+ +- PRACH:** IQ decompression\* → RE demapping → Root sequence correlation → IFFT → Noise estimation → Peak search → Preamble detection + delay estimation → L2+ +- SRS:** IQ decompression\* → RE demapping → Channel estimation → L2+ +- PT-RS:** IQ decompression\* → RE demapping → Sequence detection → L2+ + +Note: \* indicates IQ decompression is part of the O-RAN FH (7-2x lower layer split). + +AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 2/3/4) + +**Figure 7.1.3.4.3.3-1: AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 2/3/4)** + +The AAL\_ PUCCH\_ HIGH -PHY profile is executed in inline acceleration mode. + +**7.1.3.4.4 AAL\_PRACH\_HIGH-PHY** + +Figure 7.1.3.4.4-1 highlights the set of accelerated functions that defines the AAL\_PRACH\_HIGH-PHY Profile. + +The set of accelerated functions associated with the processing of PRACH preamble is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Root sequence generation and correlation +- IFFT +- Noise estimation +- Peak search for power delay profile +- Preamble detection and delay/timing advance estimation + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. +61 + +![](048c79215cc1eade95d9583a272a1757_img.jpg) + +| | | | | | | | | +|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|----------------------------------------------------------------------------------------------------------------------------------------|--|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| L2 + | | | | | | | | +| <b>PUSCH</b><br><b>UL data</b><br>TB CRC check<br>CB CRC + CB Desegmentation<br>LDPC decoding<br>Rate dematching<br>CB Deconcatenation<br>Descrambling<br>Demodulation<br>IDFT for DFT-s-OFDM<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | | | <b>PUCCH format 1</b><br><b>UCI</b><br>Demodulation<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | <b>PUCCH format 2/3/4</b><br><b>UCI</b><br>CRC check<br>Polar/Block decoding<br>Rate dematching<br>Descrambling<br>Demodulation<br>IDFT for DFT-s-OFDM<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | +| <b>PUCCH format 0</b><br><b>UCI</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | | <b>PRACH</b><br>Preamble detection + delay estimation<br>Peak search<br>Noise estimation<br>IFFT<br>Root sequence correlation<br>RE mapping<br>IQ decompression* | | <b>SRS</b><br>Channel estimation<br>RE demapping<br>IQ decompression* | | <b>PT-RS</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +Figure 7.1.3.4.4-1: AAL\_PRACH\_HIGH-PHY Profile + +The AAL\_PRACH\_HIGH-PHY Profile is executed in inline acceleration mode. + +##### 7.1.3.4.5 AAL\_SRS\_HIGH-PHY + +Figure 7.1.3.4.5-1 highlights the set of accelerated functions that defines the AAL\_SRS\_HIGH-PHY Profile. + +The set of accelerated functions associated with the processing of SRS is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation + +![](8311c3131ecc1a6432e91ac9d0a501ff_img.jpg) + +| | | | | | | | | +|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|----------------------------------------------------------------------------------------------------------------------------------------|--|------------------------------------------------------------------------------------------------|--| +| L2 + | | | | | | | | +| <b>PUSCH</b><br><b>UL data</b><br>TB CRC check<br>CB CRC + CB Desegmentation<br>LDPC decoding<br>Rate dematching<br>CB Deconcatenation<br>Descrambling<br>Demodulation<br>IDFT for DFT-s-OFDM<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | <b>PUCCH format 2/3/4</b><br><b>UCI</b><br>CRC check<br>Polar/Block decoding<br>Rate dematching<br>Descrambling<br>Demodulation<br>IDFT for DFT-s-OFDM<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | <b>PUCCH format 1</b><br><b>UCI</b><br>Demodulation<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | <b>PUCCH format 0</b><br><b>UCI</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | | +| | | <b>PRACH</b><br>Preamble detection + delay estimation<br>Peak search<br>Noise estimation<br>IFFT<br>Root sequence correlation<br>RE demapping<br>IQ decompression* | | <b>SRS</b><br><b>Channel estimation</b><br><b>RE mapping</b><br><b>IQ decompression*</b> | | <b>PT-RS</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +Figure 7.1.3.4.5-1: AAL\_SRS\_HIGH-PHY Profile + +The AAL\_SRS\_HIGH-PHY Profile is executed in inline acceleration mode. + +##### 7.1.3.4.6 AAL\_PT-RS-UL\_HIGH-PHY + +Figure 7.1.3.4.6-1 highlights the set of accelerated functions that defines the AAL\_PT-RS-UL\_HIGH-PHY Profile. + +The set of accelerated functions associated with the processing of PT-RS-UL sequence is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Sequence detection + +![](9b762b5fa2d457ee3aeb793a8c634341_img.jpg) + +| L2 + | | | | | | | | | | +|---------------------------------------|--|--|--|--|--|--|--|--|--| +| <b>PUSCH</b> | | | | | | | | | | +| <b>UL data</b> | | | | | | | | | | +| TB CRC check | | | | | | | | | | +| CB CRC + CB Desegmentation | | | | | | | | | | +| LDPC decoding | | | | | | | | | | +| Rate dematching | | | | | | | | | | +| CB Deconcatenation | | | | | | | | | | +| Descrambling | | | | | | | | | | +| Demodulation | | | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | | | +| Channel equalization | | | | | | | | | | +| Channel estimation | | | | | | | | | | +| RE demapping | | | | | | | | | | +| IQ decompression* | | | | | | | | | | +| <b>PUCCH format 0</b> | | | | | | | | | | +| <b>UCI</b> | | | | | | | | | | +| Sequence detection | | | | | | | | | | +| RE demapping | | | | | | | | | | +| IQ decompression* | | | | | | | | | | +| <b>PUCCH format 1</b> | | | | | | | | | | +| <b>UCI</b> | | | | | | | | | | +| Demodulation | | | | | | | | | | +| Channel equalization | | | | | | | | | | +| Channel estimation | | | | | | | | | | +| RE demapping | | | | | | | | | | +| IQ decompression* | | | | | | | | | | +| <b>PUCCH format 2/3/4</b> | | | | | | | | | | +| <b>UCI</b> | | | | | | | | | | +| CRC check | | | | | | | | | | +| Polar/Block decoding | | | | | | | | | | +| Rate dematching | | | | | | | | | | +| Descrambling | | | | | | | | | | +| Demodulation | | | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | | | +| Channel equalization | | | | | | | | | | +| Channel estimation | | | | | | | | | | +| RE demapping | | | | | | | | | | +| IQ decompression* | | | | | | | | | | +| <b>PRACH</b> | | | | | | | | | | +| Preamble detection + delay estimation | | | | | | | | | | +| Peak search | | | | | | | | | | +| Noise estimation | | | | | | | | | | +| IFFT | | | | | | | | | | +| Root sequence correlation | | | | | | | | | | +| RE demapping | | | | | | | | | | +| IQ decompression* | | | | | | | | | | +| <b>SRS</b> | | | | | | | | | | +| Channel estimation | | | | | | | | | | +| RE demapping | | | | | | | | | | +| IQ decompression* | | | | | | | | | | +| <b>PT-RS</b> | | | | | | | | | | +| Sequence detection | | | | | | | | | | +| RE mapping | | | | | | | | | | +| IQ decompression* | | | | | | | | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | | | + +**Figure 7.1.3.4.6-1: AAL\_PT-RS-UL\_HIGH-PHY profile** + +The AAL\_PT-RS-UL\_HIGH-PHY profile is executed in inline acceleration mode. + +##### 7.1.3.4.7 AAL\_UPLINK\_HIGH-PHY + +Figure 7.1.3.4.7-1 highlights the set of accelerated functions that defines the AAL\_UPLINK\_HIGH-PHY Profile, this profile includes the aggregation of all the individual uplink channel profiles as follows: + +###### PUSCH: + +- **Data:** see list of accelerated functions associated with the processing of PUSCH data, per section 7.1.3.4.2 +- **DM-RS:** see list of accelerated functions listed in section 7.1.3.4.6, implemented to process DM-RS samples. +- **PT-RS:** see list of accelerated functions listed in section 7.1.3.4.6 + +###### PUCCH: + +- **Format 0:** see list of accelerated functions listed in section 7.1.3.4.3.1 +- **Format 1:** + - **UCI:** see list of accelerated functions listed in section 7.1.3.4.3.2 + - **DM-RS:** see list of accelerated functions listed in section 7.1.3.4.6, implemented to process DM-RS IQ samples. +- **Formats 2/3/4:** + - **UCI:** see list of accelerated functions listed in section 7.1.3.4.3.3 + - **DM-RS:** see list of accelerated functions listed in section 7.1.3.4.6, implemented to process DM-RS IQ samples. + +###### PRACH: + +- see list of accelerated functions listed in section 7.1.3.4.4 + +###### SRS: + +- see list of accelerated functions listed in section 7.1.3.4.5 + +The AAL\_UPLINK\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.4.7-1: AAL_UPLINK_HIGH-PHY Profile block diagram showing the flow of data and processing blocks for PUSCH, PUCCH, PRACH, SRS, and PT-RS.](9c313862e3c0b943015f24082015b23e_img.jpg) + +The diagram illustrates the AAL\_UPLINK\_HIGH-PHY Profile architecture. It shows the flow of data and processing blocks for various uplink channels and signals. The blocks are organized into columns representing different processing stages and channels. + +- PUSCH UL data:** TB CRC check, CB CRC + CB desegmentation, LDPC decoding, Rate dematching, CB deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE mapping, IQ decompression\*. +- PUCCH format 2/3/4 UCI:** CRC check, Polar/Block decoding, Rate dematching, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE mapping, IQ decompression\*. +- PUCCH format 1 UCI:** Demodulation, Channel equalization, Channel estimation, RE mapping, IQ decompression\*. +- PUCCH format 0 UCI:** Sequence detection, RE mapping, IQ decompression\*. +- PRACH:** Preamble detection + delay estimation, Peak search, Noise estimation, IFFT, Root sequence correlation, RE mapping, IQ decompression\*. +- SRS:** Channel estimation, RE mapping, IQ decompression\*. +- PT-RS:** Sequence detection, RE mapping, IQ decompression\*. + +The diagram is bounded by L2+ at the top and O-RAN FH (7-2x lower layer split) at the bottom. + +Figure 7.1.3.4.7-1: AAL\_UPLINK\_HIGH-PHY Profile block diagram showing the flow of data and processing blocks for PUSCH, PUCCH, PRACH, SRS, and PT-RS. + +Figure 7.1.3.4.7-1: AAL\_UPLINK\_HIGH-PHY Profile + +#### 7.1.3.5 O-DU AAL Profiles for mMTC + +##### 7.1.3.5.1 AAL\_NPDSCH\_FEC + +Figure 7.1.3.5.1-1: highlights the set of accelerated functions that define the AAL\_NPDSCH\_FEC Profile. These include: + +- CRC Generation +- Tail-Biting Convolutional Coding +- Rate Matching + +The AAL\_NPDSCH\_FEC Profile is implemented as a look aside accelerator. + +![Figure 7.1.3.5.1-1: AAL_NPDSCH_FEC Profile. This block diagram shows the functional split between L2+ and O-RAN FH (7-2x lower layer split). The L2+ layer contains NPDSCH TB(s) and NPBCH TB processing. NPDSCH TB(s) includes TB CRC attachment, Tail Biting Convolutional Coding, Rate matching, CB concatenation, Scrambling, Modulation, Layer mapping, Precoding*, RE mapping, and IQ compression*. NPBCH TB includes PBCH payload generation, CRC attachment, Tail Biting Convolutional Coding, Rate Matching, Scrambling, Modulation, Layer Mapping, Precoding*, RE mapping, and IQ compression*. The O-RAN FH layer contains N PDCCH (DCI) and NPSS/NSSS/NRS/NPRs/NWUS processing. N PDCCH (DCI) includes CRC attachment, Tail Biting Convolutional Coding, Rate matching, Scrambling, Modulation (QPSK), Precoding*, RE mapping, and IQ compression*. NPSS/NSSS/NRS includes Sequence Generation and Modulation. NPRs/NWUS includes Sequence Generation and Modulation.](468bc263d5fb57494881d4abafa4be24_img.jpg) + +Figure 7.1.3.5.1-1: AAL\_NPDSCH\_FEC Profile. This block diagram shows the functional split between L2+ and O-RAN FH (7-2x lower layer split). The L2+ layer contains NPDSCH TB(s) and NPBCH TB processing. NPDSCH TB(s) includes TB CRC attachment, Tail Biting Convolutional Coding, Rate matching, CB concatenation, Scrambling, Modulation, Layer mapping, Precoding\*, RE mapping, and IQ compression\*. NPBCH TB includes PBCH payload generation, CRC attachment, Tail Biting Convolutional Coding, Rate Matching, Scrambling, Modulation, Layer Mapping, Precoding\*, RE mapping, and IQ compression\*. The O-RAN FH layer contains N PDCCH (DCI) and NPSS/NSSS/NRS/NPRs/NWUS processing. N PDCCH (DCI) includes CRC attachment, Tail Biting Convolutional Coding, Rate matching, Scrambling, Modulation (QPSK), Precoding\*, RE mapping, and IQ compression\*. NPSS/NSSS/NRS includes Sequence Generation and Modulation. NPRs/NWUS includes Sequence Generation and Modulation. + +Figure 7.1.3.5.1-1: AAL\_NPDSCH\_FEC Profile + +##### 7.1.3.5.2 AAL\_NPDCCH\_FEC + +Figure 7.1.3.5.2-1 highlights the set of accelerated functions that define the AAL\_NPDCCH\_FEC Profile. These include + +- CRC Generation +- Tail-Biting Convolutional Coding +- Rate Matching + +The AAL\_NPDCCH\_FEC Profile is implemented as a look aside accelerator. + +![](f6067443347eac89ec6c099520a88d08_img.jpg) + +| | | | | | | +|-----------------------------------|----------------------------------|--|----------------------------------|----------------------|---------------------| +| L2+ | | | | | | +| <b>NPDSCH TB(s)</b> | | | <b>NPBCH TB</b> | | | +| TB CRC attachment | | | PBCH payload generation | | | +| Tail Biting Convolutional Coding | | | CRC attachment | | | +| | <b>N PDCCH (DCI)</b> | | Tail Biting Convolutional Coding | | | +| Rate matching | CRC attachment | | | | | +| CB concatenation | Tail Biting Convolutional Coding | | Rate Matching | | | +| Scrambling | Rate matching | | Scrambling | <b>NPSS/NSSS/NRS</b> | <b>NPRS/NWUS</b> | +| Modulation | Scrambling | | Modulation | Sequence Generation | Sequence Generation | +| Layer mapping | Modulation (QPSK) | | Layer Mapping | Modulation | Modulation | +| Precoding* | Precoding* | | Precoding* | | Precoding* | +| RE mapping | RE mapping | | RE mapping | | RE mapping | +| IQ compression* | IQ compression* | | IQ compression* | | IQ compression* | +| O-RAN FH (7-2x lower layer split) | | | | | | + +Figure 7.1.3.5.2-1: AAL\_NPDCCH\_FEC Profile + +##### 7.1.3.5.3 AAL\_NPBCH\_FEC + +Figure 7.1.3.5.3-1 highlights the set of accelerated functions that define the AAL\_NPBCH\_FEC Profile. These include + +- CRC Generation +- Tail-Biting Convolutional Coding +- Rate Matching + +The AAL\_NPBCH\_FEC Profile is implemented as a look aside accelerator. + +![](cbe2443cfd9d21a538e0b82d7095d7d4_img.jpg) + +| | | | | | | +|-----------------------------------|--|-----------------------------------------|--|----------------------|---------------------| +| L2+ | | | | | | +| <b>NPDSCH TB(s)</b> | | <b>NPBCH TB</b> | | | | +| TB CRC attachment | | PBCH payload generation | | | | +| Tail Biting Convolutional Coding | | <b>CRC attachment</b> | | | | +| Rate matching | | <b>Tail Biting Convolutional Coding</b> | | | | +| CB concatenation | | <b>Rate Matching</b> | | | | +| Scrambling | | Scrambling | | <b>NPSS/NSSS/NRS</b> | <b>NPRS/NWUS</b> | +| Modulation | | Modulation | | Sequence Generation | Sequence Generation | +| Layer mapping | | Layer Mapping | | Modulation | Modulation | +| Precoding* | | Precoding* | | | Precoding* | +| RE mapping | | RE mapping | | | RE mapping | +| IQ compression* | | IQ compression* | | | IQ compression* | +| O-RAN FH (7-2x lower layer split) | | | | | | + +Figure 7.1.3.5.3-1: AAL\_NPBCH\_FEC Profile + +##### 7.1.3.5.4 AAL\_NPUSCH\_FEC + +Figure 7.1.3.5.4-1 highlights the set of accelerated functions that define the AAL\_NPUSCH\_FEC Profile. These include + +- CRC Generation +- Turbo Decoding +- Rate Matching + +The AAL\_NPUSCH\_FEC Profile is implemented as a look aside accelerator. + +![AAL_NPUSCH_FEC Profile block diagram showing processing flows for NPUSCH UL data, PUSCH Format 2 UCI, and NPRACH. The diagram is organized into four main processing paths under the L2+ layer, all feeding into the O-RAN FH (7-2x lower layer split) at the bottom. The paths are: NPUSCH UL data (CRC check, Turbo decoding, Rate dematching, Descrambling, Demodulation, Layer Demapping, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE demapping, IQ decompression*), PUSCH Format 2 UCI (AC-NACK detection, Channel decoding, Rate dematching, Descrambling, Demodulation, Channel equalization, Channel estimation, RE demapping, IQ decompression*), DMRS with PUSCH Format 1 and Format 2 (Channel Estimation, RE demapping, IQ decompression*), and NPRACH (Preamble detection + delay estimation, Peak search, Noise estimation, IFFT, Root sequence correlation, RE demapping, IQ decompression*).](ee3986ed257817d27d2c122774861f5f_img.jpg) + +**L2 +** + +**NPUSCH** +**UL data** + +**CRC check** + +**Turbo decoding** + +**Rate dematching** + +Descrambling + +Demodulation + +Layer Demapping + +IDFT for DFT-s-OFDM + +Channel equalization + +Channel estimation + +RE demapping + +IQ decompression\* + +**PUSCH Format 2** +**UCI** + +AC-NACK detection + +Channel decoding + +Rate dematching + +Descrambling + +Demodulation + +Channel equalization + +Channel estimation + +RE demapping + +IQ decompression\* + +**DMRS with PUSCH** +**Format 1 and** +**Format 2** + +Channel Estimation + +RE demapping + +IQ decompression\* + +**NPRACH** + +Preamble detection + delay estimation + +Peak search + +Noise estimation + +IFFT + +Root sequence correlation + +RE demapping + +IQ decompression\* + +**O-RAN FH (7-2x lower layer split)** + +AAL\_NPUSCH\_FEC Profile block diagram showing processing flows for NPUSCH UL data, PUSCH Format 2 UCI, and NPRACH. The diagram is organized into four main processing paths under the L2+ layer, all feeding into the O-RAN FH (7-2x lower layer split) at the bottom. The paths are: NPUSCH UL data (CRC check, Turbo decoding, Rate dematching, Descrambling, Demodulation, Layer Demapping, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE demapping, IQ decompression\*), PUSCH Format 2 UCI (AC-NACK detection, Channel decoding, Rate dematching, Descrambling, Demodulation, Channel equalization, Channel estimation, RE demapping, IQ decompression\*), DMRS with PUSCH Format 1 and Format 2 (Channel Estimation, RE demapping, IQ decompression\*), and NPRACH (Preamble detection + delay estimation, Peak search, Noise estimation, IFFT, Root sequence correlation, RE demapping, IQ decompression\*). + +Figure 7.1.3.5.4-1: AAL\_NPUSCH\_FEC Profile + +## 7.2 O-CU AAL Profiles + +The O-CU AAL profiles shall be part of further study for O-RAN WG6. + +# Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.07.19 | 09.00.05 | Minor editorial fix to figure 4.2.2-1 archicture diagram, change O1dms to O1. | +| 2024.07.04 | 09.00.04 | Editorial changes to update figures throughout the document.<br><br>Updated the number of the LPU's on architecture diagram. Terminate IMS interface to HAM in example HAM software deployment scenarios. | +| 2024.07.04 | 09.00.03 | Clause 4.2.3 add requirement stating that the scope of the HAM identifier is within an O-Cloud instance. | +| 2024.07.04 | 09.00.02 | Adding picture for inline example in General Aspetcs section as it can be confusing for reader as inline is missing from general discription. | +| 2024.05.09 | 09.00.01 | Editorial changes for removal of “cloudified RAN” which is not definied on higher levels | +| 2024.03.22 | 08.00.06 | Updated with minor editorial fixes for publication. | +| 2024.03.07 | 08.00.05 | Modified high level architecture diagram with deletion of the interface between DMS and NF so that readers are not confused about API which is not existent yet and is out of scope of this document. | +| 2024.03.07 | 08.00.04 | Updates from CR <a href="#">ERI-2024.1.23-WG6-CR-0046-AAL GAP CADS reference correction.docx</a><br><br>1. “VOID” the reference to the CADS TR in the normative reference section.<br><br>2. Change the reference to CADS for O-Cloud Platform Software to a reference of the WG1 OAD TS.<br><br>3. Change the reference to CADS for the synchronization topologies to the WG4 CUS TS. | +| 2024.03.07 | 08.00.03 | 1. Correct definitions of Accelerated Function and AAL Profile to remove the constraint that it be a “Cloudified Network Function” (that term is no longer defined anyway).<br><br>2. Add clarification text to figure 4.2-1 to point out that support of O1 by the AAL Application is not a requirement.<br><br>3. Move the text at the bottom of the terms and conditions section to section 4.2. The text is unchanged.<br><br>4. Update Figure 4.2-5 to change “NF Application” to “AAL Application”. | +| 2024.01.18 | 08.00.02 | To improve readability and improve clarity, existing text was moved to different clauses and additional clarification points were considered from <a href="#">DCM-2023.10.24-WG6-GAP-updates_section_2.2_v03</a> | +| 2024.01.18 | 08.00.01 | Updated diagrams to align format. | +| 2023.11.28 | 08.00 | Published from version 07.00.09 | +| 2023.10.14 | 07.00.09 | Editorial Updates, fix broken reference. | +| 2023.10.11 | 07.00.08 | Update format to latest O-RAN TS template | + +| | | | +|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.10.11 | 07.00.07 | Add text that describes the DMS to AAL Application interface.<br><a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/QCM-2023.10.24-WG6-CR-0048-Add_AAL_DMS_Description.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/QCM-2023.10.24-WG6-CR-0048-Add_AAL_DMS_Description.docx?api=v2</a><br><br>Editorial updates. | +| 2023.10.11 | 07.00.06 | Avoid mixing definitions with characteristics and requirements, clause 1.3.1 and 4.1. Updated definition section to provide additional clarity. | +| 2023.09.11 | 07.00.05 | Editorial updates in clauses 1.2, 1.3.2, 2.1, 3.1,4.2<br><a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/DCM-2023.10.24-WG6-GAP_editorial_updates_v03.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/DCM-2023.10.24-WG6-GAP_editorial_updates_v03.docx?api=v2</a> | +| 2023.09.11 | 07.00.04 | Removed reference to alarms which are no longer in scope of this document. | +| 2023.09.11 | 07.00.03 | Add example diagrams of how AAL Software drivers are deployments, added clarification on how AAL SW drivers are installed and managed.<br><br><a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/INT-10-06-23-WG6-CR-18-AAL-GAnP-driver-deployments-clarification.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/INT-10-06-23-WG6-CR-18-AAL-GAnP-driver-deployments-clarification.docx?api=v2</a> | +| 2023.09.11 | 07.00.02 | Captured the architectural aspects for use of AAL APIs without impacting the O-RAN architecture.<br><a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/ERI.AO-2023.08.03-WG6-CR-006-AAL%20GAP%20Agreements%20to%20support%20open%20multi-vendor%20Interfaces%20for%20AAL%20APIs.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/ERI.AO-2023.08.03-WG6-CR-006-AAL%20GAP%20Agreements%20to%20support%20open%20multi-vendor%20Interfaces%20for%20AAL%20APIs.docx?api=v2</a> | +| 2023.09.11 | 07.00.01 | Add description of a software repository use by HAM in section 1.3.1.<br><a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/ERI-2023.08.08-WG6-CR-005-AAL%20GAP%20SW%20Repo%20Clarifications.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/ERI-2023.08.08-WG6-CR-005-AAL%20GAP%20SW%20Repo%20Clarifications.docx?api=v2</a> | +| 2023.14.07 | 06.00.07 | Implemented CR from <a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/INT-VMW-06-30-23-WG6-CR-AAL-GAnP-Editorial-rearrange-principles-and-arch_v1.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/INT-VMW-06-30-23-WG6-CR-AAL-GAnP-Editorial-rearrange-principles-and-arch_v1.docx?api=v2</a> Move 2.5 to chapter 3 and move 3.1 & 3.2 to chapter 2 to better align with chapter contents. | +| 2023.14.07 | 06.00.06 | Implemented CR from <a href="#">SLA-2023.05.16-ORAN.WG6-CR 03-AAL-GAnP-R003-v06.00.doc</a> . State that HAM is part of and is integrated along with O-Cloud Platform software | +| 2023.30.06 | 06.00.05 | Implemented CR from <a href="#">VMW-2023.05.31-WG6-CR-AAL%20Architecture%20in%20GAnP.docx</a> | +| 2023.30.06 | 06.00.04 | Implemented CR from <a href="#">SLA-2023.05.17-ORAN.WG6.CR%20004-AAL-GAnP-R003-v06.00.docx</a> | +| 2023.30.06 | 06.00.03 | Implemented CR from <a href="#">DCM-2023.05.17-WG6-AAL-ETSI</a> | +| 2023.30.06 | 06.00.02 | Implemented CR from <a href="#">QCM-2023.04-24-WG6-CR-0034-AAL-GAnP-Clarify-AAL-Mgmt-Functions.docx</a> | +| 2023.27.04 | 06.00.01 | Implemented CR from <a href="#">ERI-202304.02-WG6_CR_AAL-GAnP_Editorial.docx</a> and various editorial comments from <a href="#">July Train WIKI</a> | +| 2023.10.03 | 05.00.04 | Definition of new FFT Profile | +| 2023.10.03 | 05.00.03 | Describe the chaining of AAL Profile Instances in Sec 4.1.6 AAL-LPU Principles | + +| | | | +|------------|----------|---------------------------------------------------------------------------------------| +| 2023.10.03 | 05.00.02 | Modification of Figure 2.7 and 2.8 in GAnP, changes to sections 2.5.2 and 5.1.3.1.2.. | +| 2022.09.12 | 05.00.01 | Implemented CR from QCM-24 Editorial modifications to correct AAL terms | +| 2022.11.07 | 04.00.04 | Implemented CR from INT-0014 (example AAL-LPU mapping diagrams) | +| 2022.11.07 | 04.00.03 | Implemented CR from QCM-0013 (ER Diagram) | +| 2022.11.07 | 04.00.02 | Implemented CR from QCM-0020 (AAL App Definition) | +| 2022.10.25 | 04.00.01 | Implemented CRs NOK-0001 (AALProfile_v02) | +| 2022.09.02 | 04.00 | Final version 04.00 | + +1 \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/135d6702b4f82ef3da58c67c3401c7a6_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/135d6702b4f82ef3da58c67c3401c7a6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1baa0e8634e4b07bf5ce94efdb65d602929908a7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/135d6702b4f82ef3da58c67c3401c7a6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:36eb7283b62c182e5bd6e70fd5d59d1d3daeee74b2acbf355d46bfbe32cad2a7 +size 135964 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1535c252e46507edb528d95576205808_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1535c252e46507edb528d95576205808_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1537eea899d92723e869acf9d0d4917cbf7af625 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1535c252e46507edb528d95576205808_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:411418610dfbd77603081e1b77535ed809c1a8019d6273f600a79da92e315192 +size 171304 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1a0bfaeada675879df21fedb1adc863d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1a0bfaeada675879df21fedb1adc863d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9b3907ab524ccd7562c31d5d721cc02b56e26408 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1a0bfaeada675879df21fedb1adc863d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e49988c9aa16ccacb6d4186d4b73cf5f0beba65ad7f77e700d60b0d0ba06a987 +size 168833 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1cb29b8fd8e4a828f60ce6313a2eacdd_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1cb29b8fd8e4a828f60ce6313a2eacdd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8f22f8e65279e7f91a27f7f4b8f2b87564d0f797 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1cb29b8fd8e4a828f60ce6313a2eacdd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:592d1d051d38b08d6e159ae0bb032295bb4e1d6984f029b552a15f8f045d7f55 +size 145164 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7b84e262d2fc7e0b59b4101053a42526958b946a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1ebce4b6e9501aa98d47582544fadc94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e7bdaaf5aacb655dae815886fc7e68b08115ae4458078ccf72b022c81a0a12c +size 4142 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1fcffcebbafd755a0425238bfb181331_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1fcffcebbafd755a0425238bfb181331_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8402cb86e141bdac79e0a7c32a3fb7783001acb4 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/1fcffcebbafd755a0425238bfb181331_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:40eb22c39fb5c51bb2ec8e4a742e22904f003438dd6e861b97bb5fe7356600d4 +size 139426 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/22ffc42c30d66b92d27e0c50ad70ab32_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/22ffc42c30d66b92d27e0c50ad70ab32_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9d7552414c597db60994b027f629c0c6a55490ff --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/22ffc42c30d66b92d27e0c50ad70ab32_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3afeb6c93ec950ea28c3d31d6a7c86d885f28c0a44abbfc0901f6eb46a65a026 +size 139754 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2368c7b690b2d16a027385323a0c4645_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2368c7b690b2d16a027385323a0c4645_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b3454652827ffdf7dbbcffc21c5e0ad369cf5478 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2368c7b690b2d16a027385323a0c4645_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a2bb7515fc8b185bfb370125ed5d6bbb62c763d417b6a8fa8a03fa5b34515afc +size 147183 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/26e728cf1f9325df2e9a7528c5fa2a7c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/26e728cf1f9325df2e9a7528c5fa2a7c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..60eeb631197546a7ba84b5a01c68d0ebc5138323 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/26e728cf1f9325df2e9a7528c5fa2a7c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3306f9970a3d29b7e3f145450cf0d8664c8ee8fa10be1db497bf50b5939afedc +size 139158 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2a69f8d527e2dec67be51d8e5e0db717_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2a69f8d527e2dec67be51d8e5e0db717_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fcf4af036dc42a68df1efe92ba5c1ed95ff9e645 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2a69f8d527e2dec67be51d8e5e0db717_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:baaf0c644cd775178f5135e284680d566ce1f33076ecda01fd98d7d88981ba1f +size 43857 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2c6ff96172dc261a119121358ac82fd8_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2c6ff96172dc261a119121358ac82fd8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0db3b594cc0282d4194a1571e495865e983f7246 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2c6ff96172dc261a119121358ac82fd8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:95139f2d56d3e0da7e4d0cae18a90b855f2ffabffaf22c60fe9652a2f011758b +size 140668 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2ef3048df29ee6142187d01b0efe18a6_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2ef3048df29ee6142187d01b0efe18a6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6837436830c10dd6a417d97282fedcbacb355ca0 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/2ef3048df29ee6142187d01b0efe18a6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b2017bb84de11330f4609c77646ae76306c2611466c1510ba0c71c8823509892 +size 141544 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/30467bcdb4ab509953319f4d3e925239_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/30467bcdb4ab509953319f4d3e925239_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4acef63f4ce0a8e9d9a012aa293a3c13e18a04eb --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/30467bcdb4ab509953319f4d3e925239_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c0c3a18781318411497af3773f90118a2440a7d8e8b57ad21ea75d2c25dd19ae +size 28521 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/305f671e59ed4f84345c3f5fdf0e2630_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/305f671e59ed4f84345c3f5fdf0e2630_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6411758bab38b3b9ea25dddc3ab087a1b96e0997 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/305f671e59ed4f84345c3f5fdf0e2630_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bdc9f4b15a85b09971de63d2760f3c2d18d1e5506565028f8fe6920b570ede76 +size 42732 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/334ece6638e13194e67fd840cf52025e_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/334ece6638e13194e67fd840cf52025e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dac980677a21e069d3b0d1629b2937f58500e392 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/334ece6638e13194e67fd840cf52025e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bd69afcb1b8af53ab5a81b62ecbc7ac000099df02cfe78350fa40d28ea657dc9 +size 91304 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/395893d9fb65b475cf1adfeef8f9f57a_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/395893d9fb65b475cf1adfeef8f9f57a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d43f3c8de4e3651afcfa1fd69e3250d813dabd05 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/395893d9fb65b475cf1adfeef8f9f57a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b3b190d9bbc79474793ed1f1cfcea6279b900772b9c24fe168f3f9947d30824f +size 22678 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/3aa4cd4077e12736b418ba70bf564c5c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/3aa4cd4077e12736b418ba70bf564c5c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bfc2151da204e2e011e0b586b577b8388065e472 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/3aa4cd4077e12736b418ba70bf564c5c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4fc7bd0f62d5d9c25a3abd6bb56833e25c858b56b2d78fc32a4ffaa2662d87be +size 55020 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/3cb3e39773b70e6ce0a91b75ac973087_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/3cb3e39773b70e6ce0a91b75ac973087_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5764ab2dfb2440fc25232399480c24355ee5b3e7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/3cb3e39773b70e6ce0a91b75ac973087_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64b51437591d85167214720b37ffa348ba25cc7e86344be73eefb9b8ec74f2bb +size 170659 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/43cf35939eea6a924b51be1f1b604d7b_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/43cf35939eea6a924b51be1f1b604d7b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ee0baac9c26e3f6ef2d4a40bd86295512c5ea262 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/43cf35939eea6a924b51be1f1b604d7b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:334f081382c487e02914433168833da33731c1aa4cc509f1c1e7a30494d61954 +size 142634 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/445ce018fc60b589e6fb221505024dae_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/445ce018fc60b589e6fb221505024dae_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5aa660003f0afc9ab37ca6ea8ea4ef060bc47db1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/445ce018fc60b589e6fb221505024dae_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:40c8a327fd144e9d3812d005013cbf8d16d53a5ff91d9c794e611c9afe90815f +size 52576 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/521999b2671d776d7fffb27e0d4a35b2_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/521999b2671d776d7fffb27e0d4a35b2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cbc733b587d5bbda2cd7c5dd0efaeffc8f7bb18f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/521999b2671d776d7fffb27e0d4a35b2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cd348adf668fe27519e104e8e207444283357af39cfe9d5b7e2cdd634a34d237 +size 34286 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/57eb1fd61c2ec867ba8077c797de3cfd_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/57eb1fd61c2ec867ba8077c797de3cfd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f4d2402d2fcc57fcfe5fa6752f0cf28b3ca5cb71 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/57eb1fd61c2ec867ba8077c797de3cfd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa176447fabdc83cb099d98334b027b1882a0d6f71372c21f00c319cd377f1f +size 171237 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/5aa3730ff05d28dd2e5a311f4e762ccc_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/5aa3730ff05d28dd2e5a311f4e762ccc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6804d9f4e2d17e4657d227950d777e4b27f75319 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/5aa3730ff05d28dd2e5a311f4e762ccc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:044b97436a312bcfe1a30e75b8e29ed9fbe1bb2864f3bee284f09ec1480a36ee +size 51056 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..44e4ca1e706fffc218594e75b7fbdfaeee43149d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/5be6fdffe3f59c1089ecfcbd9b5d6f6a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ba36991bdae993881d357810ae680e8b2718eeb75c0831521a0cdc2d6e038f2 +size 4147 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/5ddb688513464b42be655923b0a9a1b4_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/5ddb688513464b42be655923b0a9a1b4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4dfdf8788a52aa22549990b8310647c066030de1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/5ddb688513464b42be655923b0a9a1b4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7d22cee34b5d057d482cc21d3b53425251e9024246b76b743929b4c417a25f61 +size 38184 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/63722e07c40a795771d2b5eb1007d537_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/63722e07c40a795771d2b5eb1007d537_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bb2eded13299a70c2a33010799ef50dc35bd6ca6 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/63722e07c40a795771d2b5eb1007d537_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b7e593a10ab05d368de3a0543f0297b639f61008169acc2844802140e2eb9fe6 +size 106741 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/6483ff7c5003c9b7a0ed8bcc98e902db_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/6483ff7c5003c9b7a0ed8bcc98e902db_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1048b58a2a1ff220a16bba1487f11da3530d96e7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/6483ff7c5003c9b7a0ed8bcc98e902db_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:07ebc0ec3a8fc142655c672be968832aa9a01870e83858eb14dac5d52002f47c +size 137641 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/6565f31e5207edefc397e4c337893a93_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/6565f31e5207edefc397e4c337893a93_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4298c6725e51e3c5959a040d40503b6cbeb1fbb0 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/6565f31e5207edefc397e4c337893a93_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4ee79540eb6934849935641287e3cca36a2907578d37082231617552168886c9 +size 145430 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/6a6617dd6d290796bcc857899d902833_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/6a6617dd6d290796bcc857899d902833_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..02181ec35ed85ba6cf7467d71ef45076bbbb5ce5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/6a6617dd6d290796bcc857899d902833_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2869077a317fc6203e9adb5fc1c0a1ec19d9723154f13ae1740bbab9d80792e0 +size 11461 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/722fb847287bcec6fa8a7313bd7f3d25_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/722fb847287bcec6fa8a7313bd7f3d25_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8732cbc0c518699096a10e7c4c6a159a21271220 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/722fb847287bcec6fa8a7313bd7f3d25_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b880b790bb1b1ade502ec75bfcb9054cf2fbb607625bbe562433478dd3250146 +size 34712 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/729efb5720a0bc11767164cfa1d4a527_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/729efb5720a0bc11767164cfa1d4a527_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0f4c06214c8ae311d586e55deb7d0ba782c0af8b --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/729efb5720a0bc11767164cfa1d4a527_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bd70e53823c23c475fe78b2ed55a00acb82159de41b7b23c2c9e918aa2475858 +size 139943 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/76a302df4399dd6ca2f9df806090579c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/76a302df4399dd6ca2f9df806090579c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..913567d31347a1acace42d7ad1c88cc29b81cff2 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/76a302df4399dd6ca2f9df806090579c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48345b415b0c173d45cca3b037916c5f1bcfdf991a7d10b99add0a20eeed50e1 +size 37436 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/7c4b14b9a068a7634206a06b2ce30490_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/7c4b14b9a068a7634206a06b2ce30490_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..02b56bcb0dbf3c52182f70b9eaac0ed482a31c9e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/7c4b14b9a068a7634206a06b2ce30490_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e94fc68facdf6572aafef4303004d76df793a000c87acfff91b6fc026591638 +size 147072 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/85ee300213fbdc8a49d75ea52141666d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/85ee300213fbdc8a49d75ea52141666d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dc6b48422f520494a35b42f62fdd4ffdbb4ddb96 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/85ee300213fbdc8a49d75ea52141666d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:890b29c88edd11aff1a5a92b1bfd39477cab9f87f7703de367fd58ce34cb2628 +size 45728 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/8a747e4b6d0784428f4707593ae27081_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/8a747e4b6d0784428f4707593ae27081_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6f86bac2fec2f47acdf03f447a02ec011ff0bfee --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/8a747e4b6d0784428f4707593ae27081_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f3f19571358388f98b677fb28d02c2d650f8b6bd79c62fd3cb86005272964733 +size 136996 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/8fc2043ef639df5f35083f4053f361bf_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/8fc2043ef639df5f35083f4053f361bf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e7e1674ec1be3ac6ee6ca730c134e1232c1beee3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/8fc2043ef639df5f35083f4053f361bf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9f1b80e4cc2b47e74ba803f032cb45bab2839ca05037569c61a45b97b11fe97a +size 22944 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/96fa2d208d302896ba2c6aeeb363d4ad_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/96fa2d208d302896ba2c6aeeb363d4ad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..585b32af9824478670e150c475aee4cc3d54ea2d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/96fa2d208d302896ba2c6aeeb363d4ad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4992530830e63ab5aa9b731f3a93515213a869a92581b0b33f50b42307078a8e +size 4490 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/984de82d60d4e4b7e342cd926fc34212_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/984de82d60d4e4b7e342cd926fc34212_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..14d71308a96de98178a931a38998b8d6ab8f092a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/984de82d60d4e4b7e342cd926fc34212_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6e1ab22e0edc95966d90c221a4d1ec1cb330fa347021c0d50e7b52e734e8f3d6 +size 86172 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/99e5cd41877d35e56d036042dac4cca5_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/99e5cd41877d35e56d036042dac4cca5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f6d4d17f4df08fd29c12ca966c132ac1d109847c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/99e5cd41877d35e56d036042dac4cca5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0862980e3a2c3634ee9610d0452aa39099a9403c1ba63c5cbdefd09d0257fcd3 +size 145731 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/9e099a1139b4e9a1d7f5a2c775d8b548_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/9e099a1139b4e9a1d7f5a2c775d8b548_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f52e704c54678340d7278482d867427493c791f2 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/9e099a1139b4e9a1d7f5a2c775d8b548_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ef39d7f258fe9ba8fcb87a92a36b1ecfa7611e7fd3fa4e529ea18d19fa888fd +size 162573 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/a463ae6e10ae63f88a0e5c683372dd0b_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/a463ae6e10ae63f88a0e5c683372dd0b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de3717d5c6f440bcdbbb98f3df24deb30b123402 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/a463ae6e10ae63f88a0e5c683372dd0b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e022aac8771bcc01311f9b3895ef0b74d196eb4cda57a9548f2e8e169f9ecb99 +size 46919 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/ac1df873c5c60114cd5ef7e209cb7dcd_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/ac1df873c5c60114cd5ef7e209cb7dcd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3c98f19dc4ff290ba3ebf90f6323e6f426125bc3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/ac1df873c5c60114cd5ef7e209cb7dcd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3a1c3af0abb2e454e2c14cf1b2b4a36f10c2eed5228c84db54b1fb4e00bbb91e +size 52463 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/b1459d87cd99cf742aab66c58a9fc00e_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/b1459d87cd99cf742aab66c58a9fc00e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1f1e09eb2e09d019037ad5d6c812ddba382c22ae --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/b1459d87cd99cf742aab66c58a9fc00e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6f10def823364ca3af7edb32a430686cd3687e5739abc8678b023b70498824f6 +size 27488 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/b3340bb90cba9e433238521218898503_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/b3340bb90cba9e433238521218898503_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c2d3773f24d268a21aa7edfa01659a5752900605 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/b3340bb90cba9e433238521218898503_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0baf68d53a5ebfeca8320e8783c2d8864703d6eea23bde96a3d39951759695d8 +size 41119 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/b572d8c7d42c86287763f9810594cf7c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/b572d8c7d42c86287763f9810594cf7c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9910054ad13216ed87231493019bcc3a09ac390e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/b572d8c7d42c86287763f9810594cf7c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d52d04e8988e87a4b85ba78383473e66ffde767de5deddc780d6aeb3a8bfdc12 +size 21335 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/c0ac65c22121c83581896fac19443988_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/c0ac65c22121c83581896fac19443988_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8569cd3e619c92e91fb2e80de1a9c2b7091c5834 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/c0ac65c22121c83581896fac19443988_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ac5c77caa3e43cc39a81cbb21004dd620b425c7c6de421c17c2fad16e1301a53 +size 73483 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/c25024451bf62c0e9f2a77a989775ade_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/c25024451bf62c0e9f2a77a989775ade_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2ccb67e9acb76be53e0aeea4c4c1fed433bb54a5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/c25024451bf62c0e9f2a77a989775ade_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9c010d6e15495167a7b45274cff32b7f4aeb71cf35247e319edaaa52fed76e62 +size 172529 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/c78cc0b7b3fd41cb118b11ef3c94d045_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/c78cc0b7b3fd41cb118b11ef3c94d045_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..421e67c868c24e498493f76bbee8cd761d6a7ebc --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/c78cc0b7b3fd41cb118b11ef3c94d045_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7e2b4d7c11d3ee5f85dddbea396b3554baf6e3d693ae7d64bd9507a2875d1fda +size 60185 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/cd2b7bfd679915e1c0f6943fe668f214_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/cd2b7bfd679915e1c0f6943fe668f214_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7d5e9e59c3dc5689684a229837216ad6bb35d91f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/cd2b7bfd679915e1c0f6943fe668f214_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:263e681578b7d73fd3038a425154dbe9097582885f12366dfe30cf9ec4cc1ecb +size 29412 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d14d91fc3ecb06d48c80be1e9ed6084b_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d14d91fc3ecb06d48c80be1e9ed6084b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..73c61afce82e8e3d98d7b9631f041f74b385e36a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d14d91fc3ecb06d48c80be1e9ed6084b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:69320b3708c2631177273c7bb4516b1473bb6128a1b9541f94447e8084c84fef +size 28224 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d1ee69fc6f80df98aab4bee4509bb3ba_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d1ee69fc6f80df98aab4bee4509bb3ba_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2084380237ede48f1ea76bb10707bfbf3d3e1d48 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d1ee69fc6f80df98aab4bee4509bb3ba_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:03051e83317690305428b1dee2cde083011d2081354c88dff560cdfd2353c3f0 +size 21739 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d21941f1aa786639b1022a9d38d00841_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d21941f1aa786639b1022a9d38d00841_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d12afccc86bb265b051f91455819d755b273ba8a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d21941f1aa786639b1022a9d38d00841_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:998e2db13c10bf16ab1baeffe7db4d88102088e8d4748484c18d66bf77fb8419 +size 171408 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d3ac347210ad889d4e7296db2f602c59_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d3ac347210ad889d4e7296db2f602c59_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dea76cc56076ce29659e10772c160305f5a80e9b --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d3ac347210ad889d4e7296db2f602c59_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce3b03d8bd444e5da17b243617790eae9c1d186154b3f538539658d4b1282754 +size 64358 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d4d9ae3b65bcaae8a97e03a99dfb422b_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d4d9ae3b65bcaae8a97e03a99dfb422b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..40d3201cc379026f7c25cfd5c59fc6a9b411538a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/d4d9ae3b65bcaae8a97e03a99dfb422b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:016bdb60ab26d38a68c000d6465cb7b1e25b15edd0391cbc111df04c94a55673 +size 21786 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/dd29fae82ae7f2977dc147f776f500da_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/dd29fae82ae7f2977dc147f776f500da_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..84e7d50cea73a59292ce511d8524a134777b3e57 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/dd29fae82ae7f2977dc147f776f500da_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fae74549cc29621ed86fbfeefb27c1818d76184f1e531a0e76409ff79cbb9ce6 +size 144889 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/de329a5fb451359c8f0050ce690fa4f2_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/de329a5fb451359c8f0050ce690fa4f2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2b252545796ea408ae3ede7b6f30f90ff0f2b1a9 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/de329a5fb451359c8f0050ce690fa4f2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:df04bcb73149d2281e274fcd03153dd7040b6467c596bb5f04ad62544a0acb12 +size 37712 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/dea084f6bb5c3f13476addd074da28e7_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/dea084f6bb5c3f13476addd074da28e7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0d97226440064179b641a7e025b05c72d0ce05c1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/dea084f6bb5c3f13476addd074da28e7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:13e166faae799b84093c29267ae518d8e646e1a6ef9a37a6d62d982c5a55f1db +size 139248 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/e14133d8413be822c4cf5e9d9fa1680f_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/e14133d8413be822c4cf5e9d9fa1680f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c109f398466ef248355444af2340f9af28288939 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/e14133d8413be822c4cf5e9d9fa1680f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2154e15aa67367471e4d7c94a415395562c4fb8c5071bfb25442cf9744f7348d +size 34327 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/eea56fc90b16d8b6fbf7a2a3cb30b69f_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/eea56fc90b16d8b6fbf7a2a3cb30b69f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cf9bd25ce921ff40af179faf5a6c60563a9766a7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/eea56fc90b16d8b6fbf7a2a3cb30b69f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cc29cbcd51aa4f06634855a48c6b866ebde42a082973cd14667eca2f9cfbb6a +size 152037 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/eed97810b73ce2008906a0918abed322_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/eed97810b73ce2008906a0918abed322_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e9d056186f91071754a1bd66cc5b0f58f9cdcd1d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/eed97810b73ce2008906a0918abed322_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a6feea577002af775f92c1c073ef8e278549447e23549760a568e59d2a4c42d6 +size 4142 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/f1d9df9c24542116e1519cf988e23aec_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/f1d9df9c24542116e1519cf988e23aec_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..02661dcade2644120b0c27823bcb0e0a7d032c99 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/f1d9df9c24542116e1519cf988e23aec_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:30f8342900eeb7f806e04cceac045f84f1cdc9e5c5bad803d81c3a1a30b7ffb9 +size 60390 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/f5f7e673b788fc81825d475f36bf9acd_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/f5f7e673b788fc81825d475f36bf9acd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2807ecedc18fe2c50690f76d9f142c9dafc7198e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/f5f7e673b788fc81825d475f36bf9acd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b25a74e0f656223e0fc3564e65dd79a8e3ab121e0be263cd02891bbdd2ec5e2d +size 34969 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/f89a396ed972d10263aa24c104c62c58_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/f89a396ed972d10263aa24c104c62c58_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..98c7c13521c3a41a6c69b9c8bcb47b5c03659d5b --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/f89a396ed972d10263aa24c104c62c58_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c16f1b200927ef035cd107a28d184009361f2728c30f3b7b3af37c4a4793930b +size 137575 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/fa49186bb622c095765fd8ddc772729a_img.jpg b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/fa49186bb622c095765fd8ddc772729a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1af4baa9997cb759fd2b6a6708563bc34a058214 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/fa49186bb622c095765fd8ddc772729a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b7de6899a3e71e7d5cb96e3cf5688867518bde70faaa5a1d8d15817d1aa6097 +size 4042 diff --git a/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/raw.md b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..450d485752ce553eb6a854eb2690c51c532fd00a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00/raw.md @@ -0,0 +1,2463 @@ + + +1 + +2 + +# **O-RAN Working Group 6 (Cloudification and Orchestration Work Group)** + +# **O-RAN Acceleration Abstraction Layer General Aspects and Principles** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +|---|---|-----------------------|---|---|-------------|------------------|---------------------------|------------------------------|-------------------------------------------------------|-------------|---------------|--------------------|----------------------|-----------------------------|------------------------------------|----------------|-----------------------|------------------------------|---------------------|----------------------------------------------|-----------------------------------|------------------------------|--------------------------------------------------------------------|-------------------------|---------------------|-------------------------------|-----------------------|-----------------------------------|--------------------------------|-------------------------------|-------------------------------------|--------------------------------|------------------------------------------------------------|---------------------------------------------------------------------------|-------------------------------------------------|------------------------------------------------|------------------------|--------------------------------|--------------------------------------------|-----------------------------------------------------------------|--------------------------------------|---------------------------------------------|-----------------------------------------|-------------------------|----------------|------------------------------------|-------------------------------|------------------|-------------------------|-------------------------------| +| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 | 51 | +| | | List of Figures ..... | | | 1. | 2. | 2.1 | 2.2 | 3. | 3.1 | 3.2 | 3.3 | 4. | 4.1 | 4.2 | 4.2.1 | 4.2.2 | 4.2.3 | 4.2.4 | 4.2.5 | 4.3 | 4.3.1 | 5. | 5.1 | 5.1.1 | 5.1.2 | 5.1.3 | 5.1.4 | 5.1.5 | 5.1.6 | 5.1.7 | 5.1.8 | 5.1.9 | 5.1.10 | 5.1.11 | 5.1.12 | 5.1.13 | 5.1.14 | 5.2 | 5.2.1 | 5.2.2 | 5.2.3 | 5.2.4 | 6. | 6.1 | 6.2 | 6.2.1 | 6.2.2 | 6.2.3 | 6.2.4 | +| | | 4 | | | Scope ..... | References ..... | Normative References..... | Informative references ..... | Definitions of terms, symbols and abbreviations ..... | Terms ..... | Symbols ..... | Abbreviations..... | General Aspects..... | Hardware Acceleration ..... | AAL Architecture and concepts..... | Overview ..... | AAL Architecture..... | HW Accelerator Manager ..... | AAL Interfaces..... | AAL Deployment in O-Cloud environments ..... | Relationship with Standards ..... | Relationship with ETSI ..... | AAL Interface definition General Principles and Requirements ..... | General Principles..... | Extensibility ..... | Interrupt and Poll Mode ..... | HW Independence ..... | Discovery and Configuration ..... | Multiple AAL-LPU Support ..... | AAL offload capabilities..... | Look-aside Acceleration Model ..... | Inline Acceleration Model..... | AAL Application interface Concurrency and Parallelism..... | Separation of Control and User Plane AAL Application interface APIs ..... | Support of Versatile Acceleration Payload ..... | Support of Different Transport Mechanisms..... | AAL API namespace..... | Chaining of AAL Profiles ..... | High-PHY Profile Specific Principles ..... | Separation of Cell and Slot Level Parameter Configurations..... | SFN/slot-based Synchronization ..... | Compatibility with O-RAN FH interface ..... | Inline Profile for High-PHY Stack ..... | AAL-LPU Principles..... | Overview ..... | LPU Deployment and Operation ..... | Example AAL-LPU Mapping ..... | Statistics ..... | Memory Management ..... | Run Time Configurations ..... | +| | | | | | 6 | 7 | 7 | 7 | 9 | 9 | 10 | 10 | 11 | 11 | 12 | 12 | 13 | 15 | 16 | 18 | 20 | 20 | 22 | 22 | 22 | 22 | 22 | 22 | 22 | 23 | 23 | 24 | 25 | 25 | 25 | 25 | 26 | 26 | 28 | 28 | 28 | 29 | 29 | 30 | 30 | 31 | 31 | 34 | 34 | 34 | + +| | | | | +|----|----------------------|------------------------------------------------------------------------------------|----| +| 1 | 6.2.5 | AAL Profile(s) offload, processing status query and processed data retrieval ..... | 35 | +| 2 | 6.2.6 | AAL-LPU Exposure..... | 35 | +| 3 | 6.2.7 | Accelerator configuration options between IMS & FOCOM..... | 37 | +| 4 | 7. | AAL Profiles ..... | 39 | +| 5 | 7.1 | O-DU AAL Profiles..... | 39 | +| 6 | 7.1.1 | O-DU Protocol Stack Reference ..... | 39 | +| 7 | 7.1.2 | O-DU Protocol Stack Reference for mMTC ..... | 43 | +| 8 | 7.1.3 | O-DU AAL Profile Definitions ..... | 47 | +| 9 | 7.2 | O-CU AAL Profiles ..... | 70 | +| 10 | Annex (informative): | Change History ..... | 71 | +| 11 | | | | + +12 + +# List of Figures + +| | | | +|----|-------------------------------------------------------------------------------------------------------------------|----| +| 1 | | | +| 2 | Figure 4.1-1: Example illustration of the effect of hardware acceleration on functional compute performance. .... | 12 | +| 3 | Figure 4.2.2-1: High Level AAL Architecture Diagram..... | 14 | +| 4 | Figure 4.2.2-2: AAL Resource Relationship and Cardinality..... | 15 | +| 5 | Figure 4.2.3-1 Example HAM software deployment scenarios..... | 16 | +| 6 | Figure 4.2.4-1: AAL Application Common and profile APIs ..... | 17 | +| 7 | Figure 4.2.5-1: Accelerator APIs/Libraries in Container (left) and Virtual Machine Implementations (right) ..... | 18 | +| 8 | Figure 4.2.5.1-1: Example AAL Implementation Software deployment contained within O-Cloud Platform Software | | +| 9 | only..... | 19 | +| 10 | Figure 4.2.5.1-2: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and | | +| 11 | NF Deployment ..... | 19 | +| 12 | Figure 4.2.5.1-3: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and | | +| 13 | NF Deployment in a virtual machine environment..... | 20 | +| 14 | Figure 5.1.5-1: Logical Representation of AAL Application interface support for multiple AAL-LPUs ..... | 23 | +| 15 | Figure 5.1.7-1: AAL Application interface look-aside acceleration model - Data flow ..... | 23 | +| 16 | Figure 5.1.8-1: AAL Application interface inline acceleration model - Data flow ..... | 24 | +| 17 | Figure 5.1.8-2: User plane dataflow paths in look-aside and inline acceleration architectures. .... | 25 | +| 18 | Figure 5.1.14-1: Data flow through unchained AAL Profiles ..... | 26 | +| 19 | Figure 5.1.14-2: Data flow through chained AAL Profiles ..... | 27 | +| 20 | Figure 5.1.14-3: Dataflow through chained lookaside HW Accelerator for consecutive Hi-PHY functions. .... | 28 | +| 21 | Figure 5.1.14-4: Dataflow through chained lookaside HW Accelerator for consecutive and non-consecutive PHY..... | 28 | +| 22 | Figure 5.2.4-1: Partial Inline Model for AAL Hi-PHY Profile..... | 29 | +| 23 | Figure 6.2.1-1: Scenario 1: A single AAL LPU exposes a single AAL Profile Queue used by a single AAL Application. | | +| 24 | ..... | 31 | +| 25 | Figure 6.2.1-2: A single HW Accelerator supporting two LPU's each assigned to individual AAL Applications ..... | 32 | +| 26 | Figure 6.2.1-3: Two HW Accelerators each supporting a single AAL-LPU assigned to a single AAL Application. .... | 32 | +| 27 | Figure 6.2.1-4: A single AAL LPU exposes two AAL Profile Queues used by a single AAL Application. .... | 33 | +| 28 | Figure 6.2.1-5: A single AAL LPU supporting two AAL Profile Instances exposes two AAL Profile Queues used by a | | +| 29 | single AAL Application..... | 33 | +| 30 | Figure 6.2.1-6: AAL-LPU Mapping example showing chained profile support ..... | 34 | +| 31 | Figure 6.2.5.1- 1 Various AAL Bypass scenarios..... | 35 | +| 32 | Figure 6.2.6.2.1-1: Example AAL-LPU and profile supported ..... | 36 | +| 33 | Figure 6.2.6.2.1-2: Example HW Accelerator configuration..... | 36 | +| 34 | Figure 6.2.6.2.1-3: Example assignment of AAL-LPUs and supported profiles to POD ..... | 36 | +| 35 | Figure 6.2.6.2.2-1: Example AAL Application configured AAL-Profile-Instances..... | 37 | +| 36 | Figure 7.1.1-1: O-DU PHY processing blocks for 5G NR Downlink ..... | 39 | +| 37 | Figure 7.1.1-2: O-DU PHY processing blocks for 5G NR Uplink ..... | 41 | +| 38 | Figure 7.1.2-1: O-DU PHY processing blocks for mMTC Downlink..... | 44 | +| 39 | Figure 7.1.2-2: O-DU PHY processing blocks for mMTC Uplink..... | 46 | +| 40 | Figure 7.1.3.2.1-1: AAL_MU-MIMO_PRECODER_WEIGHTS_CALC ..... | 48 | +| 41 | Figure 7.1.3.2.1-2: Example AAL_MU-MIMO_PRECODER_WEIGHTS_CALC use. .... | 48 | +| 42 | Figure 7.1.3.2.2-1: AAL_FFT ..... | 49 | +| 43 | Figure 7.1.3.2.2-2: AAL_FFT example for SRS Processing ..... | 50 | +| 44 | Figure 7.1.3.3.1-1: AAL_PDSCH_FEC Profile ..... | 51 | +| 45 | Figure 7.1.3.3.2-1: AAL_PDSCH_HIGH-PHY Profile..... | 52 | +| 46 | Figure 7.1.3.3.3-1: AAL_PDCCH_HIGH-PHY Profile..... | 53 | +| 47 | Figure 7.1.3.3.4-1: AAL_PBCH_HIGH-PHY Profile ..... | 54 | +| 48 | Figure 7.1.3.3.5-1: AAL_CSI-RS_HIGH-PHY Profile..... | 55 | +| 49 | Figure 7.1.3.3.6-1: AAL_PT-RS-DL_HIGH-PHY Profile..... | 56 | +| 50 | Figure 7.1.3.3.7-1AAL_DOWNLINK_HIGH-PHY Profile..... | 57 | +| 51 | Figure 7.1.3.4.1-1: AAL_PUSCH_FEC Profile ..... | 58 | +| 52 | Figure 7.1.3.4.2-1 : AAL_PUSCH_HIGH-PHY Profile..... | 59 | +| 53 | Figure 7.1.3.4.3.1-1: AAL_PUCCH_HIGH-PHY Profile (PUCCH format 0)..... | 60 | +| 54 | Figure 7.1.3.4.3.2-1: AAL_PUCCH_HIGH-PHY Profile (PUCCH format 1)..... | 61 | +| 55 | Figure 7.1.3.4.3.3-1: AAL_PUCCH_HIGH-PHY Profile (PUCCH format 2/3/4)..... | 62 | +| 56 | Figure 7.1.3.4.4-1: AAL_PRACH_HIGH-PHY Profile..... | 63 | +| 57 | Figure 7.1.3.4.5-1: AAL_SRS_HIGH-PHY Profile ..... | 64 | +| 58 | Figure 7.1.3.4.6-1: AAL_PT-RS-UL_HIGH-PHY profile ..... | 65 | + +| | | | +|---|------------------------------------------------------|----| +| 1 | Figure 7.1.3.4.7-1: AAL_UPLINK_HIGH-PHY Profile..... | 66 | +| 2 | Figure 7.1.3.5.1-1: AAL_NPDSCH_FEC Profile..... | 67 | +| 3 | Figure 7.1.3.5.2-1: AAL_NPDCCH_FEC Profile ..... | 68 | +| 4 | Figure 7.1.3.5.3-1: AAL_NPBCH_FEC Profile ..... | 69 | +| 5 | Figure 7.1.3.5.4-1: AAL_NPUSCH_FEC Profile..... | 70 | +| 6 | | | + +# 7 Foreword + +8 This Technical Specification (TS) has been produced by W6 of the O-RAN Alliance. + +9 The content of the present document is subject to continuing work within O-RAN and may change following formal O- +10 RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O- +11 RAN with an identifying change of version date and an increase in version number as follows: + +12 version xx.yy.zz + +13 where: + +14 xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, +15 updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +16 yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. +17 Always 2 digits with leading zero if needed. + +18 zz: the third digit-group included only in working versions of the document indicating incremental changes during +19 the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if +20 needed. + +# 21 Modal verbs terminology + +22 In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and +23 "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression +24 of provisions). + +25 "**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +26 + +# --- 1. Scope + +This document defines O-RAN O-Cloud hardware accelerator interface functions and protocols for the O-RAN AAL interface. The document studies the functions conveyed over the interface, including configuration and management functions, procedures, operations and corresponding solutions, and identifies existing standards and industry work that can serve as a basis for O-RAN work. + +# 2. References + +## 2.1 Normative References + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN WG1 Architecture Description +- [2] O-RAN WG1 OAM Architecture +- [3] Void +- [4] ETSI GS NFV-IFA 002: "Network Functions Virtualization (NFV) Release 2; Acceleration Technologies; VNF Interfaces Specification" +- [5] [ETSI GS NFV-IFA 019: "Network Function Virtualization \(NFV\); Acceleration Technologies; Acceleration Resource Management Interface Specification; Release 3"](#) +- [6] [5G; NR; Physical Channels and Modulation 3GPP TS 38.211 v15.2.0 Release 15](#) +- [7] [5G; NR; Multiplexing and Channel Coding 3GPP TS 38.212 v15.2.0 Release 15](#) +- [8] [LTE; E-UTRA Physical Channels and Modulation 3GPP TS 36.211 v15.2.0 Release 15](#) +- [9] [LTE; E-UTRA Multiplexing and Channel Coding 3GPP TS 36.212 v15.2.1 Release 15](#) +- [10] ETSI GS [NFV-IFA 001](#): "Network Functions Virtualisation (NFV); Acceleration Technologies; Report on Acceleration Technologies & Use Cases" +- [11] O-RAN WG6 O2 General Aspects and Principles +- [12] O-RAN WG6 Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN +- [13] ETSI GS NFV-IFA [011](#): "Network Functions Virtualisation (NFV) Release 4; Management and Orchestration; VNF Descriptor and Packaging Specification" +- [14] ETSI GR NFV-IFA 046: "Network Functions Virtualisation (NFV) Release 5; Architectural Framework; Report on NFV support for virtualisation of RAN" +- [15] O-RAN WG6 AAL Common API R003 +- [16] O-RAN WG4 Control, User and Synchronization (CUS) Plane Specification + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- 1 [i.1] [Vocabulary for 3GPP Specifications \(TR21.905\)](#) +- 2 +- 3 + +# 3. Definitions of terms, symbols and abbreviations + +## 3.1 Terms + +For the purpose of this document the terms and definitions given in O-RAN WG6 Cloudification and Orchestration Use Cases (UC) and Requirements for O-RAN Virtualized RAN [13], ETSI GS NFV-IFA 002 [4], and the following apply: + +**Hardware (HW) Accelerator (HWA)** is a specialized HW implementation that can offload processing from application(s) running on a General-Purpose Processor. The Hardware (HW) Accelerator is a physical Managed Element as defined in [13]. + +NOTE: Examples of Hardware Accelerators include ASIC, FPGA, DSP and GPU. + +NOTE: Throughout this document, the term “Accelerator” and “Hardware (HW) accelerator” are used interchangeably. + +**Acceleration Abstraction Layer (AAL)** specifies a common and consistent set of interfaces used by different entities to enable interaction with different types of HW Accelerators within an O-Cloud instance. + +**AAL Implementation** is a realization of an AAL including but not limited to the software libraries, drivers and the Hardware Accelerator + +**Accelerated Function (AF)** is a representation of a workload building block that an accelerator processes on behalf of an AAL Application within an O-RAN Network Function in an O-Cloud [1]. + +**AAL Application (AAL-App)** is defined as a workload that can offload Accelerated Functions to AAL-LPU(s). + +NOTE: Unless explicitly noted, the term Application refers to an AAL Application in AAL specifications. + +NOTE: Unless explicitly noted, the terms Application, NF Application, L2 Application, VNF/CNF, or NF workload accessing the AAL in figures of this present document refers to an AAL Application. + +**AAL Profile(s) (AAL-Profile)** specify one or more Accelerated Functions that an accelerator processes on behalf of an AAL Application within an O-RAN Network Function in an O-Cloud [1]. + +**AAL Operations** actions supported by the AAL interface. + +**AAL Profile Instance (AAL-Profile-Instance)** is an executing instance of an AAL profile that can be used by an AAL Application via the AAL interface. The AAL-Profile-Instance executes within an AAL-LPU execution environment. + +**AAL Logical Processing Unit (AAL-LPU)** is a logical representation of resources within an instance of a HW Accelerator (example: there can be multiple processing units or subsystems on a hardware accelerator, or resource partitioning (hard – dedicated resources, soft – soft resources) and these can be logically represented as a AAL Logical Processing Unit) + +**AAL Profile Queue** is a logical grouping construct and may be used by the AAL Application to group operations together. For example, AAL Profile Queues may access specific resources (compute, I/O) of an AAL-LPU executing specific AAL Profile Instances(s). + +**AAL Profile Queue ID** is a unique index used to designate the AAL Profile Queue in function exposed by specific AAL profile. + +NOTE: An AAL Profile Queue or an AAL Profile Queue ID does not reflect a HW design or an AAL Implementation specification + +**HW Accelerator Manager (HAM)** is an acceleration management function, that provides management capabilities for the HW Accelerator(s) and the AAL-LPU's in the O-Cloud Node. Management capabilities include but not limited to lifecycle management, configuration, updates/upgrades and failure handling of the HWA and the LPUs. The HAM may use the services of an external software repository to securely transfer approved software artifacts, for example FW/SW images, binaries, libraries and configuration data. The specification of a software repository and the communication with the HAM are outside the scope of O-RAN specifications. The HW Accelerator Manager is considered an O-Cloud Platform Software. + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in [i.1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in [i.1]. + +| | | +|-------------|-----------------------------------------------------------------| +| AF | Accelerated Function | +| AAL | Acceleration Abstraction Layer | +| AAL-App | Acceleration Abstraction Layer - Application | +| AAL-LPU | Acceleration Abstraction Layer - LPU | +| AALI-C | Acceleration Abstraction Layer Interface-Common | +| AALI-C-Mgmt | Acceleration Abstraction Layer Interface-Common-Management | +| AALI-C-App | Acceleration Abstraction Layer Interface-Common-Application | +| AALI-P | Acceleration Abstraction Layer Interface-Profile | +| BF | Beam-forming | +| CNF | Cloudified Network Function | +| DFT/iDFT | Discrete Fourier Transform / Inverse Discrete Fourier Transform | +| DMS | Deployment Management Services | +| FCAPS | Fault, Configuration, Accounting, Performance, Security | +| FEC | Forward Error Correction | +| FFT/iFFT | Fast Fourier Transform / inverse Fast Fourier Transform | +| HWA | Hardware Accelerator | +| IMS | Infrastructure Management Services | +| LPU | Logical Processing Unit | +| RB | Resource Block | +| SMO | Service Management and Orchestration | +| UC | Use Case | +| VNF | Virtual Network Function | + +# --- 4. General Aspects + +## 4.1 Hardware Acceleration + +In the design of digital computing systems, ranging from general-purpose processors to fully customized hardware, there is a tradeoff between flexibility and efficiency, with efficiency increasing by orders of magnitude when any given application is implemented in hardware. The range of implementation options includes general-purpose processors (GPPs) such as CPUs, more specialized processors such as Graphics Processing Units (GPUs), functions implemented on field-programmable gate arrays (FPGAs), and fixed-functions implemented on application-specific integrated circuits (ASICs). Hardware accelerator is a specialized HW implementation that can offload processing from application(s) running on the General-Purpose Processor (GPP). Any transformation of data or computation can be implemented purely in software running on a generic CPU, or purely in a specialized hardware accelerator, or using a combination of both. The implementation of computing tasks in hardware to improve performance is known as hardware acceleration. The hardware acceleration can be implemented in the form of lookaside or inline mode where in the former case, the host CPU invokes an accelerator for data processing and receives the result after processing is complete, while in the latter case, the accelerator, after being invoked by the host CPU with the request for data processing, completes the processing request of data received from a source node and directly transfers the post-processed data to a destination node, where the source or destination node can be different than host CPU (e.g., an Ethernet Interface). The principle of hardware acceleration and functional offloading in lookaside mode and inline is illustrated in Figure 4.1-1, allowing the application to offload workload to a hardware accelerator and to continue performing other work in parallel- this could be to continue to execute other software tasks in parallel or to sleep and wait for the accelerator hardware to complete. The hardware acceleration boosts application performance in environments with compute-intensive, deeply pipelined, massively parallel operations as shown in Figure 4.1-1. This model requires the support of two operations, one for initiating the offload and another for retrieving the operation once complete. + +### Without hardware acceleration – serial execution + +![Diagram showing serial execution of five functions (Func 1 to Func 5) on a CPU. The functions are connected in a single sequence: CPU -> Func 1 -> Func 2 -> Func 3 -> Func 4 -> Func 5 -> Exit.](6a6617dd6d290796bcc857899d902833_img.jpg) + +``` + +graph LR + CPU --- Func1[Func 1] + Func1 --- Func2[Func 2] + Func2 --- Func3[Func 3] + Func3 --- Func4[Func 4] + Func4 --- Func5[Func 5] + Func5 --- Exit(( )) + +``` + +Diagram showing serial execution of five functions (Func 1 to Func 5) on a CPU. The functions are connected in a single sequence: CPU -> Func 1 -> Func 2 -> Func 3 -> Func 4 -> Func 5 -> Exit. + +### With hardware acceleration – massively parallel execution within and across functions + +#### Lookaside + +![Diagram showing lookaside hardware acceleration. The CPU handles Func 1 and Func 5. The Accelerator handles Func 2, Func 3, and Func 4. Arrows show data flow from Func 1 to Func 2, 3, and 4, and from Func 3, 4, and 5 to the next stage.](395893d9fb65b475cf1adfeef8f9f57a_img.jpg) + +``` + +graph LR + CPU --- Func1[Func 1] + Accelerator --- Func2[Func 2] + Accelerator --- Func3[Func 3] + Accelerator --- Func4[Func 4] + CPU --- Func5[Func 5] + Func1 --> Func2 + Func1 --> Func3 + Func1 --> Func4 + Func2 --> Func5 + Func3 --> Func5 + Func4 --> Func5 + Func5 --- Exit(( )) + +``` + +Diagram showing lookaside hardware acceleration. The CPU handles Func 1 and Func 5. The Accelerator handles Func 2, Func 3, and Func 4. Arrows show data flow from Func 1 to Func 2, 3, and 4, and from Func 3, 4, and 5 to the next stage. + +Accelerator handles compute-intensive, deeply pipelined, massively parallel operations. The CPU handles other operations + +#### Inline + +![Diagram showing inline hardware acceleration. The CPU handles Func 1. The Accelerator handles Func 2, Func 3, and Func 4. Func 5 is also handled by the Accelerator. Arrows show data flow from Func 1 to Func 2, 3, and 4, and from Func 4 to Func 5.](8fc2043ef639df5f35083f4053f361bf_img.jpg) + +``` + +graph LR + CPU --- Func1[Func 1] + Accelerator --- Func2[Func 2] + Accelerator --- Func3[Func 3] + Accelerator --- Func4[Func 4] + Accelerator --- Func5[Func 5] + CPU --- Exit(( )) + Func1 --> Func2 + Func1 --> Func3 + Func1 --> Func4 + Func2 --> Func5 + Func3 --> Func5 + Func4 --> Func5 + Func5 --- Exit + +``` + +Diagram showing inline hardware acceleration. The CPU handles Func 1. The Accelerator handles Func 2, Func 3, and Func 4. Func 5 is also handled by the Accelerator. Arrows show data flow from Func 1 to Func 2, 3, and 4, and from Func 4 to Func 5. + +**Figure 4.1-1: Example illustration of the effect of hardware acceleration on functional compute performance.** + +## 4.2 AAL Architecture and concepts + +### 4.2.1 Overview + +The goal of the acceleration abstraction layer (AAL) is to specify a common and consistent set of interfaces to enable interactions with the HW Accelerators and facilitates decoupling of an AAL Application, from a specific HW implementation. To accommodate the many different combinations of HW and SW implementation and many different network deployment scenarios, the AAL introduces the concept of an AAL profile which is used to distinguish between the different combinations of accelerated functions to be offloaded. + +- AAL Applications that utilize the AAL APIs render the same functionality as described in the O-RAN specifications describing the AAL Application [1]. +- AAL Applications that utilize the AAL APIs shall preserve the interface definitions and behave the same way as described in the O-RAN specifications describing those interfaces. +- O-RAN NFs that utilize the AAL APIs shall preserve the synchronization topologies as defined in [16]. + +In addition, the AAL Specification shall define the requirements for managing the hardware accelerator in the O-Cloud instance. The AAL Implementation itself shall not be defined by the AAL GAnP specification. ETSI GS NFV-IFA 002 [5] defines several abstraction models including pass through and abstracted models that can be used to realize an AAL Implementation. + +The AAL specification facilitates the following: + +An O-cloud provides the flexibility of deploying multiple software implementations from different software vendors on a common CPU-based (e.g., x86/ARM) platform with hardware accelerators (e.g., FPGA/DSP/ASIC/GPU) for specific functions, and conversely, also allows multiple physical deployment scenarios in terms of centralizing or distributing each network element with the same software implementation. + +A disaggregated and cloudified multi-vendor RAN requires common vendor-neutral APIs for managed element discovery, lifecycle management, FM/PM, and orchestration across both PNFs and VNFs in order to function as a cohesive unit that supports key lifecycle use cases such as scale-out, slice management, fault tolerance, and hitless software upgrades. + +### 4.2.2 AAL Architecture + +The end-to-end high-level AAL architecture block diagram is shown in Figure 4.2.5.1-1. For AAL Applications O1 interface usage is optional. Interaction between DMS and AAL Application is out of the scope of this document. For further understanding of the deployment and operation of AAL-LPUs please refer to section 6.2. + +![O-RAN Alliance Logo](2e578c8cfe0186eb06150f771632f7dc_img.jpg) O-RAN.WG6.AAL-GAnP-R004-v11.00 + +![Figure 4.2.2-1: High Level AAL Architecture Diagram](c25024451bf62c0e9f2a77a989775ade_img.jpg) + +Detailed Description of Figure 4.2.2-1: High Level AAL Architecture Diagram. The diagram shows the Service Management and Orchestration (SMO) at the top, containing Federated O-Cloud Orchestration and Management, Network Function Orchestrator (NFO), and RAN Network Function FCAPS. Below the SMO, there are IMS (Infrastructure Management Service) and DMS (Deployment Management Service) connected via O2ims and O2dms interfaces respectively. A HW Accelerator Manager is connected to the IMS via AAL-C-Mgmt interface. The O-Cloud Compute Node contains the HW Accelerator (Physical) and AAL Implementation, which includes AAL Profile Instances (AAL-LPU 0, AAL-LPU 1, ..., AAL-LPU N). AAL Applications are shown above the AAL Implementation, interacting via AAL-C-App and AAL-P interfaces. Legend indicates: solid red line with double arrows for 'In scope for WG6 AAL Subgroup', solid red line with single arrow for 'Standardized by WG6 O2 Subgroup', and dashed black line with double arrows for 'Vendor Specific'. + +Figure 4.2.2-1: High Level AAL Architecture Diagram + +**Figure 4.2.2-1: High Level AAL Architecture Diagram** + +Figure 4.2.2-2: shows a pictorial view of the entity relationship and cardinality between AAL entities that constitute the AAL architecture. It is not meant to be the basis of a class diagram or object model which would normally be the start of an information model. Its purpose is just to help the reader mentally conceptualize the concepts depicted. See clause 4.2.4 of the present document for a high-level description of the AAL-C-Mgmt interface and the AAL-C-App interface. See [15] for a detailed description of the specification of the AAL-C-Mgmt and AAL-C-App interfaces and the operations supported. + +AAL Managed Elements and Managed Functions are managed by SMO via the O2 interface exposed by the IMS and DMS using the AALI-C-MGMT interface terminated by the HW Accelerator Manager. Specifically, AAL Managed Elements and Managed Functions do not utilize the O1 interface for management of AAL Managed Elements and Managed Functions. + +The HW Accelerator, the HW Accelerator Manager, AAL-LPU and AAL drivers are defined as O-Cloud Platform Software for the purposes of management and orchestration [1]. The O-Cloud Infrastructure and O-Cloud Platform Software use case flows in [12] are applicable for these AAL elements. + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 14 + +![Figure 4.2.2-2: AAL Resource Relationship and Cardinality. This UML class diagram illustrates the relationships between various AAL components. The components are: IMS, HW Accelerator Manager, Hardware Accelerator, Accelerated Function, AAL Logical Processing Unit, AAL Profile, AAL Application, AAL Profile Instance, and AAL Profile Queue. Relationships include: IMS (1) manages (0..n) HW Accelerator Manager; HW Accelerator Manager (1) manages (0..n) Hardware Accelerator; Hardware Accelerator (1) resources rep by (0..n) AAL Logical Processing Unit; Accelerated Function (1..n) specifies (1..n) AAL Profile; AAL Logical Processing Unit (1..n) supports (0..n) AAL Profile; AAL Logical Processing Unit (1) uses (0..n) AAL Application; AAL Application (1) uses (0..n) AAL Profile Instance; AAL Profile (0..n) is realized by (0..n) AAL Profile Instance; AAL Profile Instance (1) consists of (0..n) AAL Profile Queue; AAL Application (1) uses (0..n) AAL Profile Queue.](85ee300213fbdc8a49d75ea52141666d_img.jpg) + +``` + +classDiagram + class IMS + class HW_Accelerator_Manager["HW Accelerator Manager"] + class Hardware_Accelerator["Hardware Accelerator"] + class Accelerated_Function["Accelerated Function"] + class AAL_Logical_Processing_Unit["AAL Logical Processing Unit"] + class AAL_Profile["AAL Profile"] + class AAL_Application["AAL Application"] + class AAL_Profile_Instance["AAL Profile Instance"] + class AAL_Profile_Queue["AAL Profile Queue"] + + IMS "1" -- "0..n" HW_Accelerator_Manager : manages + HW_Accelerator_Manager "1" -- "0..n" Hardware_Accelerator : manages + Hardware_Accelerator "1" -- "0..n" AAL_Logical_Processing_Unit : resources rep by + Accelerated_Function "1..n" -- "1..n" AAL_Profile : specifies + AAL_Logical_Processing_Unit "1..n" -- "0..n" AAL_Profile : supports + AAL_Logical_Processing_Unit "1" -- "0..n" AAL_Application : uses + AAL_Application "1" -- "0..n" AAL_Profile_Instance : uses + AAL_Profile "0..n" -.- "0..n" AAL_Profile_Instance : is realized by + AAL_Profile_Instance "1" -- "0..n" AAL_Profile_Queue : consists of + AAL_Application "1" -- "0..n" AAL_Profile_Queue : uses + +``` + +Figure 4.2.2-2: AAL Resource Relationship and Cardinality. This UML class diagram illustrates the relationships between various AAL components. The components are: IMS, HW Accelerator Manager, Hardware Accelerator, Accelerated Function, AAL Logical Processing Unit, AAL Profile, AAL Application, AAL Profile Instance, and AAL Profile Queue. Relationships include: IMS (1) manages (0..n) HW Accelerator Manager; HW Accelerator Manager (1) manages (0..n) Hardware Accelerator; Hardware Accelerator (1) resources rep by (0..n) AAL Logical Processing Unit; Accelerated Function (1..n) specifies (1..n) AAL Profile; AAL Logical Processing Unit (1..n) supports (0..n) AAL Profile; AAL Logical Processing Unit (1) uses (0..n) AAL Application; AAL Application (1) uses (0..n) AAL Profile Instance; AAL Profile (0..n) is realized by (0..n) AAL Profile Instance; AAL Profile Instance (1) consists of (0..n) AAL Profile Queue; AAL Application (1) uses (0..n) AAL Profile Queue. + +**Figure 4.2.2-2: AAL Resource Relationship and Cardinality** + +### 4.2.3 HW Accelerator Manager + +The HW Accelerator Manager (HAM) is responsible for exposing a consistent mechanism to the O-Cloud platform for the discovery, lifecycle management, fault, state/status, performance, configuration, updates/upgrades, and error handling of the HW Accelerator(s) that are part of the O-Cloud Platform Hardware. The HW Accelerator Manager exposes the AALI-C-Mgmt interface towards the IMS. The interfaces between the HW Accelerator and the HAM are vendor specific and not in the scope of AAL specifications. The HW Accelerator Manager is managed by IMS as per Figure 4.2.2-1: High Level AAL Architecture Diagram of this document. The identifier of the HW Accelerator Manager used within the IMS is unique within an O-Cloud instance. + +The HW Accelerator Manager is under the control of the O-Cloud Infrastructure. It is integrated into the Cloud Infrastructure using the O-Cloud Infrastructure's installation procedures. The HW Accelerator Manager shall be certified by the O-Cloud vendor. + +The following list provides a description of capabilities offered by HAM. The list is not exhaustive: + +- Discovery and Life Cycle Management: + - The HW Accelerator Manager provides a mechanism to expose inventory information and capabilities of the physical and logical partitioning of the hardware and software. + - The HW Accelerator Manager provides the ability to discover the capabilities of the HW Accelerator(s). + +#### - Software/ Firmware upgrade services + +- The HW Accelerator Manager allows the update and/or upgrade of the software for a HW Accelerator(s) on the O-Cloud node. An example of this may include the programming or re-programming of a downloadable firmware or driver upgrades. Updates/Upgrades can be done locally or remotely. + +#### - Configuration + +- The HW Accelerator Manager allows the configuration of the HW Accelerator as prescribed by the IMS through the AALI-C-Mgmt interface. The configuration of the HW Accelerator Manager may include HW Accelerator resource assignment to AAL-LPUs. + +#### - Fault and Performance Monitoring: + +- The HW Accelerator Manager allows exposure of faults, logs and performance measurements toward the IMS. + +#### Deployment Scenarios + +The HAM's software is deployed as part of the O-Cloud Platform software. The installation and update of the HAM's software, deployed as a part of O-Cloud platform software, is described section 3.1.2 and section 3.1.6 of Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN [13]. + +The HAM may be located on O-Cloud Nodes designated as part of the clusters used to deploy the AAL Applications (NFs) or otherwise as shown below. The figure shows HAM from the perspective of AAL-C-Mgmt interface termination point. The actual software entities (i.e., vendor specific libraries used by the HAM) for managing the HWA can reside in other locations as well. + +![Diagram illustrating Example HAM software deployment scenarios. The diagram shows four O-Cloud Node Clusters connected to O2 IMS and O2 DMS. Cluster 1 (Not hosting NFs) has a HAM container/VM on the node. Cluster 2 (hosting NFs) has a centralized HAM remote control. Cluster 3 (hosting NFs) has a HAM container/VM within the cluster. Cluster 4 (hosting NFs) has a HAM driver within the local server OS. Each cluster contains nodes with OS, HWA, and server components.](984de82d60d4e4b7e342cd926fc34212_img.jpg) + +The diagram illustrates four deployment scenarios for the Hardware Accelerator Manager (HAM) across O-Cloud Node Clusters. At the top, O2 IMS and O2 DMS are connected to the clusters. The clusters are represented by large teal boxes, each containing multiple nodes (yellow boxes with OS, HWA, and server components). + 1. **O-Cloud Node Cluster (Not hosting NFs)**: Shows a HAM container/VM on the node, which is not used for NF deployment. + 2. **O-Cloud Node Cluster (hosting NFs)**: Shows a centralized HAM remote control of the deployed cluster HWA resources. + 3. **O-Cloud Node Cluster (hosting NFs)**: Shows a HAM container/VM within the cluster deploying NF. + 4. **O-Cloud Node Cluster (hosting NFs)**: Shows a HAM driver within the local server OS. + The entire setup is labeled as O-Cloud. + +Diagram illustrating Example HAM software deployment scenarios. The diagram shows four O-Cloud Node Clusters connected to O2 IMS and O2 DMS. Cluster 1 (Not hosting NFs) has a HAM container/VM on the node. Cluster 2 (hosting NFs) has a centralized HAM remote control. Cluster 3 (hosting NFs) has a HAM container/VM within the cluster. Cluster 4 (hosting NFs) has a HAM driver within the local server OS. Each cluster contains nodes with OS, HWA, and server components. + +NOTE 1: The scenarios depicted are considered an exemplification of the most common deployment scenarios. Other locations and modelling approaches are not precluded. + +**Figure 4.2.3-1 Example HAM software deployment scenarios** + +### 4.2.4 AAL Interfaces + +The AAL interface API has two distinct parts, the first part corresponds to a set of common APIs (AALI-C) to address all the profile independent aspects of the underlying AAL Implementation(s) within an O-Cloud platform. The second part corresponds to a set of AAL profile specific APIs (AALI-P) which is specific to each defined AAL profile. + +There are two categories of AALI-C interface: + +- AALI-C-Mgmt: OAM management from the HAM toward the O-Cloud IMS for acceleration resources exposed by this interface. +- AALI-C-App: Common operations/actions/events towards the RAN AAL Application for resources exposed by this interface. + +A candidate set of functionalities for AAL services supported by the AAL common API(s) potentially includes (but is not limited to) the following: + +- Inventory Management, Fault, Performance, Configuration Management +- Software/ Firmware upgrade services +- Operations (Query status, Reset/Restart) +- Life Cycle Management of resources exposed by the interface. The AALI-C-Mgmt provides the Life Cycle Management of the HW Accelerator and the AAL-LPU resources. +- Configuration of the state of these AAL-LPU(s) (for example, start, stop, or reset of an AAL-LPU). +- Configuration of various counters and resources associated with AAL-LPU(s) (for example, performance measurements/indicators, performance monitoring metrics, events, faults etc.). +- Discovery of AAL-profile(s) supported by these AAL-LPU(s) and associated configurations etc. +- Abstraction of transport mechanism between the AAL Application and AAL Implementation + +The information model and the exact list of operations and actions applicable across AAL-C-Mgmt and AAL-C-App are defined in [15]. + +The second part of AAL interface corresponds to a set of AAL profile specific APIs (AALI-P) which is specific to each defined AAL profile. The AAL profile can be common across the different AAL Implementation accelerating the same set of AFs. It enables the AAL Application to efficiently offload an AAL profile workload to the AAL Implementation in a consistent way without requiring the HW implementations to expose every single detail of the underlying HW implementation to the AAL Applications. Figure 4.2.4-1 shows examples of the AAL APIs presented to an AAL Application in three different scenarios. + +The AALI-C-App & AALI-P APIs are internal to the AAL Application that utilize them. + +![Figure 4.2.4-1: AAL Application Common and profile APIs. The diagram shows three scenarios of AAL Application APIs. Each scenario is represented by a yellow box labeled 'AAL Application' containing a dashed box labeled 'AAL Interface'. Inside the 'AAL Interface' box are one or more grey boxes representing APIs. Scenario 1: 'AAL Common APIs' and 'AAL Profile A APIs'. Scenario 2: 'AAL Common APIs' and 'AAL Profile B APIs'. Scenario 3: 'AAL Common APIs', 'AAL Profile B APIs', and 'AAL Profile C APIs'.](5aa3730ff05d28dd2e5a311f4e762ccc_img.jpg) + +Figure 4.2.4-1: AAL Application Common and profile APIs. The diagram shows three scenarios of AAL Application APIs. Each scenario is represented by a yellow box labeled 'AAL Application' containing a dashed box labeled 'AAL Interface'. Inside the 'AAL Interface' box are one or more grey boxes representing APIs. Scenario 1: 'AAL Common APIs' and 'AAL Profile A APIs'. Scenario 2: 'AAL Common APIs' and 'AAL Profile B APIs'. Scenario 3: 'AAL Common APIs', 'AAL Profile B APIs', and 'AAL Profile C APIs'. + +**Figure 4.2.4-1: AAL Application Common and profile APIs** + +### 4.2.5 AAL Deployment in O-Cloud environments + +![Figure 4.2.5-1: Accelerator APIs/Libraries in Container (left) and Virtual Machine Implementations (right). The diagram shows two deployment scenarios. On the left, 'O-RAN Network Function in a container' is shown within an 'O-Cloud Node'. Inside the container is an 'AAL Application' which connects via 'API/Library' to an 'Acc. Driver' (e.g., AAL FEC Profile). This container sits on a 'Host OS' which also has an 'Acc. Driver' and is labeled 'Compute Svc, with Acceleration'. The entire setup is part of an 'O-Cloud Instance' which includes 'DMS' and 'IMS' components. On the right, 'O-RAN Network Function in a Virtual Machine' is shown within an 'O-Cloud Node'. Inside the VM is an 'AAL Application' which connects via 'API/Library' to an 'Acc. Driver' (e.g., AAL FEC Profile). This VM sits on a 'Guest OS' which has an 'Acc. Driver'. The VM is managed by a 'Host OS' which also has an 'Acc. Driver' and is labeled 'Compute Svc, with Acceleration'. This setup is also part of an 'O-Cloud Instance' which includes 'DMS' and 'IMS' components.](334ece6638e13194e67fd840cf52025e_img.jpg) + +Figure 4.2.5-1: Accelerator APIs/Libraries in Container (left) and Virtual Machine Implementations (right). The diagram shows two deployment scenarios. On the left, 'O-RAN Network Function in a container' is shown within an 'O-Cloud Node'. Inside the container is an 'AAL Application' which connects via 'API/Library' to an 'Acc. Driver' (e.g., AAL FEC Profile). This container sits on a 'Host OS' which also has an 'Acc. Driver' and is labeled 'Compute Svc, with Acceleration'. The entire setup is part of an 'O-Cloud Instance' which includes 'DMS' and 'IMS' components. On the right, 'O-RAN Network Function in a Virtual Machine' is shown within an 'O-Cloud Node'. Inside the VM is an 'AAL Application' which connects via 'API/Library' to an 'Acc. Driver' (e.g., AAL FEC Profile). This VM sits on a 'Guest OS' which has an 'Acc. Driver'. The VM is managed by a 'Host OS' which also has an 'Acc. Driver' and is labeled 'Compute Svc, with Acceleration'. This setup is also part of an 'O-Cloud Instance' which includes 'DMS' and 'IMS' components. + +**Figure 4.2.5-1: Accelerator APIs/Libraries in Container (left) and Virtual Machine Implementations (right)** + +The AAL specifications define the AAL interfaces (i.e AAL-C and AAL-P) and the AAL profiles that may be supported. The AAL-C-App interface is used by AAL Application to access the AAL Implementation encompassing HW Accelerator and associated SW libraries, drivers etc. In Figure 4.2.5-1 two deployment scenarios are shown, one with Containers and the other with Virtual Machines. + +Figure 4.2.5-1 also shows the O-Cloud Infrastructure Management Services and Accelerator management entity (i.e. the HAM). The orchestration of the HAM as a managed entity is outside the scope of the AAL and shall be specified in the O-RAN WG6 O2 specification [11]. + +#### 4.2.5.1 AAL Implementation Software Deployment Options + +The following figures describe AAL Implementation software deployment options. In Figure 4.2.5.1-1: there is an example where the entire AAL Implementation software is deployed as part of the O-Cloud Platform Software [3], and there is no software component dependency between NF Deployments and O-Cloud Platform Software. While in Figure 4.2.5.1-2: and Figure 4.2.5.1-3: there are other examples where part of the AAL Implementation software is deployed as part of the NF Deployment and part of O-Cloud Platform Software. In these and similar cases there is a software component dependency between the NF Deployment and the O-Cloud Platform Software, as such updating AAL Implementation software in the O-Cloud Platform Software may require an update to the NF Deployment, this is outside the scope of the AAL. + +The installation and update of the AAL Implementation software including but not limited to device drivers and libraries, deployed as a part of O-Cloud Platform Software, is described in Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN [12], clause 3.1.2 and 3.1.6. + +In the diagrams below, ‘Container image(s)’ and ‘VM image(s)’ refer specifically to containers or VMs which are being used to run AAL Applications and do not preclude the existence of other containers or images. These diagrams depict several different possible ways in which the AAL Implementation software may be deployed. The AAL Implementation software may exist wholly or partially inside or outside of the specific containers or VMs which are being used to enclose the AAL Applications. + +![Figure 4.2.5.1-1: Example AAL Implementation Software deployment contained within O-Cloud Platform Software only. The diagram shows a dashed box labeled 'Container Image' containing a yellow box labeled 'AAL Application'. Below this is a teal box labeled 'O-Cloud Platform Software' containing a yellow box labeled 'AAL Implementation Software (shared library, Kernel space drivers etc..)'. A double-headed arrow connects the 'AAL Application' box to the 'AAL Implementation Software' box.](521999b2671d776d7fffb27e0d4a35b2_img.jpg) + +Figure 4.2.5.1-1: Example AAL Implementation Software deployment contained within O-Cloud Platform Software only. The diagram shows a dashed box labeled 'Container Image' containing a yellow box labeled 'AAL Application'. Below this is a teal box labeled 'O-Cloud Platform Software' containing a yellow box labeled 'AAL Implementation Software (shared library, Kernel space drivers etc..)'. A double-headed arrow connects the 'AAL Application' box to the 'AAL Implementation Software' box. + +**Figure 4.2.5.1-1: Example AAL Implementation Software deployment contained within O-Cloud Platform Software only** + +![Figure 4.2.5.1-2: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and NF Deployment. The diagram shows a dashed box labeled 'Container Image' containing two yellow boxes: 'AAL Application' and 'AAL Implementation Software (static library, user space drivers etc..)'. Below this is a teal box labeled 'O-Cloud Platform Software' containing a yellow box labeled 'AAL Implementation Software (shared library, Kernel space drivers etc..)'. A double-headed arrow connects the 'AAL Implementation Software' box in the container image to the 'AAL Implementation Software' box in the O-Cloud Platform Software.](a463ae6e10ae63f88a0e5c683372dd0b_img.jpg) + +Figure 4.2.5.1-2: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and NF Deployment. The diagram shows a dashed box labeled 'Container Image' containing two yellow boxes: 'AAL Application' and 'AAL Implementation Software (static library, user space drivers etc..)'. Below this is a teal box labeled 'O-Cloud Platform Software' containing a yellow box labeled 'AAL Implementation Software (shared library, Kernel space drivers etc..)'. A double-headed arrow connects the 'AAL Implementation Software' box in the container image to the 'AAL Implementation Software' box in the O-Cloud Platform Software. + +**Figure 4.2.5.1-2: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and NF Deployment** + +![Diagram illustrating AAL Implementation Software Deployment split between O-Cloud Platform Software and VM Image.](f1d9df9c24542116e1519cf988e23aec_img.jpg) + +The diagram shows a layered architecture. At the bottom is a teal box labeled 'O-Cloud Platform Software'. Inside this box is a yellow box labeled 'AAL Implementation Software (shared library, Kernel space drivers etc.)'. Above this is a large white box labeled 'VM Image'. Inside the 'VM Image' box, there is a yellow box labeled 'AAL Application' at the top. Below it is another yellow box labeled 'AAL Implementation Software (static library, user space drivers etc.)'. Below that is a grey box labeled 'Guest OS'. Inside the 'Guest OS' box is a yellow box labeled 'AAL Implementation Software (shared library, kernel space drivers etc.)'. A double-headed vertical arrow connects the 'AAL Implementation Software (shared library, Kernel space drivers etc.)' box in the 'O-Cloud Platform Software' layer to the 'AAL Implementation Software (shared library, kernel space drivers etc.)' box inside the 'Guest OS' layer. + +Diagram illustrating AAL Implementation Software Deployment split between O-Cloud Platform Software and VM Image. + +**Figure 4.2.5.1-3: Example AAL Implementation Software Deployment split between O-Cloud Platform Software and NF Deployment in a virtual machine environment** + +## 4.3 Relationship with Standards + +The O-RAN AAL interface shall leverage existing standards wherever possible. + +### 4.3.1 Relationship with ETSI + +In [4,5,10], ETSI has specified a generic acceleration and abstraction model as well as acceleration resource management that have served as the basis of this specification. + +ETSI GS NFV-IFA 001 [10] provides a classification of acceleration types and describes several related use cases, for example about compute acceleration when considering Virtual Base Stations (VBS). ETSI GS NFV-IFA 002 [4] specifies an acceleration architectural model for NFV. The acceleration model considers that a single HW device exposes multiple abstract virtual accelerators and multiple instances of these virtual accelerators per VNF. ETSI GS NFV-IFA 002 [4] defines the interfaces between the NFVI and the VNF instances to support this concept. ETSI GS NFV-IFA 019 [5] defines acceleration resource management interfaces between the VIM and the NFVI (e.g., Acceleration Image Management interface). From an NFV orchestration and management perspective, acceleration capabilities are defined as part of the relevant Virtual Compute Resource information elements, i.e., a virtual compute resource (e.g., a VM) can have associated acceleration capabilities from the set of capabilities offered by the acceleration resources. For the relevant descriptors, ETSI GS NFV-IFA 011 [14] details the VirtualComputeDesc information element in VNFD which describes CPU, Memory and acceleration requirements of the virtualisation container (e.g., a VM or a set of OS containers, such as a Pod) realizing a VNFC (i.e., a component of a VNF). For containerized deployments required acceleration capabilities can be described by the extendedResourcesRequests attribute in the OsContainerDesc information element. In addition, in the case of a containerized deployment, requirements about constraints on the placement of the set of one or more OS containers (a Pod) to cluster nodes with certain capabilities, such as acceleration, can also be defined. In both cases (VM-based and OS container-based), the + +- 1 VDU information element also supports an attribute to request for additional capabilities, being acceleration related +2 capabilities as one possible example. +- 3 In ETSI NFV the concept of the abstract virtual accelerator has been devised based on the idea of an extensible para- +4 virtualised device. However, the concept has only been defined considering its use in hypervisor-based virtualization +5 systems and is not ad-hoc applicable to the case of containerized deployments without further analysis. Also, there is no +6 relevant ETSI NFV stage 3 work which can be referenced for the interfaces described in ETSI GS NFV-IFA 002 [4] +7 and ETSI GS NFV-IFA 019 [5]. This specification builds upon the concepts described by the aforementioned ETSI NFV +8 specifications but also goes beyond to consider the advances introduced by cloud native solutions, for example by +9 introducing the concept of LPUs. . +- 10 ETSI GR NFV-IFA 046 [15] profiles the NFV-MANO acceleration abstraction framework and compares it to the O- +11 RAN acceleration abstraction solution developed in the context of O-RAN, from which several challenges are further +12 described. A set of recommendations about future work in the NFV framework are derived in the same referenced +13 group report, some considering an alignment between the two designs to make ETSI NFV specifications more +14 expressive to support additional functionality. + +# --- 5. AAL Interface definition General Principles and Requirements + +## 5.1 General Principles + +The set of generic and profile-specific features of the AAL interface between the AAL application and the AAL implementation described in the following subsections are defined from an AAL Application point of view and are related to the AAL-C-App general principles and requirements. + +### 5.1.1 Extensibility + +O-RAN has defined the functions that can be accelerated by the cloud platform based on 3GPP specifications and O-RAN deployment scenarios. However, the AAL should not limit innovation of future implementations and should evolve as the specification requires. To that end, the AAL Application interface shall be extensible to accommodate future revisions of the specification. + +### 5.1.2 Interrupt and Poll Mode + +The AAL Application interface shall support multiple design choices for AAL Application vendors and shall not preclude an AAL Application/HW Accelerator vendor from adopting/supporting an interrupt-driven design or poll-mode design or any combination of both. As such, the AAL Application interface shall support both interrupt mode, poll mode and any combination of interrupt and poll modes for the data-path AAL Application interface. + +### 5.1.3 HW Independence + +AAL Application interface shall be independent of the underlying AAL Implementation. + +### 5.1.4 Discovery and Configuration + +The AAL Application interface shall enable AAL Application to discover and configure AAL-LPU(s). The AAL Application interface shall allow an AAL Application to discover what physical resources have been assigned to it from the upper layers and then to configure said resources for offload operations. + +### 5.1.5 Multiple AAL-LPU Support + +There may be scenarios where multiple AAL-LPUs (either implementing the same or different AAL profile(s) are assigned to a single AAL Application, which uses one or more of these AAL-LPU(s) as needed. The AAL Application interface shall support an AAL Application using one or more AAL-LPU(s) at the same time, as shown in Figure 5.1.5-1. + +![Figure 5.1.5-1: Logical Representation of AAL Application interface support for multiple AAL-LPUs. The diagram shows an 'AAL Application' box at the top. Two arrows labeled 'AAL Interface' point from this box to two separate boxes below. Each of these boxes contains an 'AAL Profile' box and an 'AAL-LPU' box below it.](d14d91fc3ecb06d48c80be1e9ed6084b_img.jpg) + +``` + +graph TD + AA[AAL Application] -- AAL Interface --> L1 + AA -- AAL Interface --> L2 + subgraph L1 [ ] + AP1[AAL Profile] + ALPU1[AAL-LPU] + end + subgraph L2 [ ] + AP2[AAL Profile] + ALPU2[AAL-LPU] + end + +``` + +Figure 5.1.5-1: Logical Representation of AAL Application interface support for multiple AAL-LPUs. The diagram shows an 'AAL Application' box at the top. Two arrows labeled 'AAL Interface' point from this box to two separate boxes below. Each of these boxes contains an 'AAL Profile' box and an 'AAL-LPU' box below it. + +**Figure 5.1.5-1: Logical Representation of AAL Application interface support for multiple AAL-LPUs** + +### 5.1.6 AAL offload capabilities + +The AAL Application interface in supporting different AAL profiles and AAL Implementations shall support different offload architectures including look-aside, inline, and any combination of both. An AAL Implementation shall support one or more of these offload architectures depending on the supported AAL profile(s). + +### 5.1.7 Look-aside Acceleration Model + +The AAL Application interface shall support look-aside acceleration model where the AAL Application invokes a HW Accelerator for data processing and receives the result after processing is complete. A look-aside architecture, illustrated in Figure 5.1.7-1, allows the AAL Application to offload AF(s) specified by AAL profile(s) to a HW Accelerator and continue to perform other work in parallel—this could be to continue to execute other software tasks in parallel or to sleep and wait for the HW Accelerator to complete. This model requires the AAL Application interface to support two operations, one for initiating the offload and another for retrieving the output data once complete. + +![Figure 5.1.7-1: AAL Application interface look-aside acceleration model - Data flow. The diagram shows a 'CPU' box containing an 'AAL Application' box. Below it is a 'HW Accelerator' box containing an 'AAL Profile Instance(s)' box. A red arrow labeled 'AAL Interface' points from the AAL Application to the AAL Profile Instance(s). A black arrow points from the AAL Profile Instance(s) back to the AAL Application.](cd2b7bfd679915e1c0f6943fe668f214_img.jpg) + +``` + +graph TD + subgraph CPU + AA[AAL Application] + end + subgraph HWA [HW Accelerator] + API[AAL Profile Instance(s)] + end + AA -- "AAL Interface (Input)" --> API + API -- "Output" --> AA + +``` + +→ Input to Accelerator +← Output to Accelerator + +Figure 5.1.7-1: AAL Application interface look-aside acceleration model - Data flow. The diagram shows a 'CPU' box containing an 'AAL Application' box. Below it is a 'HW Accelerator' box containing an 'AAL Profile Instance(s)' box. A red arrow labeled 'AAL Interface' points from the AAL Application to the AAL Profile Instance(s). A black arrow points from the AAL Profile Instance(s) back to the AAL Application. + +**Figure 5.1.7-1: AAL Application interface look-aside acceleration model - Data flow** + +### 5.1.8 Inline Acceleration Model + +The AAL Application interface shall support inline acceleration model where the AAL Application, after invoking a HW Accelerator for offloading AF(s) specified by AAL profile(s), does not necessarily retrieve the post processed data. Unlike the look-aside acceleration model where data source/sink is always the AAL Application (i.e., the HW Accelerator always receives the data to be processed from the AAL Application and returns the post processed data to the same), a HW Accelerator operating in inline acceleration mode receives/returns data from/to a different source/destination endpoint than the AAL Application, depending on the direction of data flow (e.g., in downlink (DL) direction versus uplink (UL) direction). Figure 5.1.8-1 shows one possible implementation of an inline acceleration model. + +![Figure 5.1.8-1: AAL Application interface inline acceleration model - Data flow. The diagram shows a CPU block containing an AAL Application block. Below the CPU is a HW Accelerator block containing two AAL Profile Instance(s) blocks, each with a Tx and Rx block. A red arrow labeled 'AAL Interface' points from the AAL Application to the AAL Profile Instance(s) in the HW Accelerator. A black arrow points from the Tx block back to the AAL Application. A red arrow points from the Rx block to the Tx block. A legend at the bottom indicates that a red arrow represents 'Input to Accelerator' and a black arrow represents 'Output to Accelerator'.](76a302df4399dd6ca2f9df806090579c_img.jpg) + +Figure 5.1.8-1: AAL Application interface inline acceleration model - Data flow. The diagram shows a CPU block containing an AAL Application block. Below the CPU is a HW Accelerator block containing two AAL Profile Instance(s) blocks, each with a Tx and Rx block. A red arrow labeled 'AAL Interface' points from the AAL Application to the AAL Profile Instance(s) in the HW Accelerator. A black arrow points from the Tx block back to the AAL Application. A red arrow points from the Rx block to the Tx block. A legend at the bottom indicates that a red arrow represents 'Input to Accelerator' and a black arrow represents 'Output to Accelerator'. + +**Figure 5.1.8-1: AAL Application interface inline acceleration model - Data flow** + +In Figure 5.1.8-1, “Tx” refers to the transmission of the data from the HW Accelerator through an egress port (e.g., an Ethernet interface) to a destination node (e.g., O-RU), while “Rx” refers to the reception of data through an ingress port (e.g., Ethernet interface) to the HW Accelerator from a source node (e.g O-RU). + +While the look-aside architecture (in DL) shall support dataflow from the CPU to the HW Accelerator and back to the CPU before being sent to the egress port (front-haul interface), the inline architecture (in DL) shall support data flow from the CPU to the HW Accelerator and directly from the HW Accelerator to the egress port (front-haul interface), instead of being sent back to the CPU. The typical user plane data flows for accelerating the O-DU High-PHY functions for the look-aside and inline architectures are as follows. + +#### Look-aside architecture user plane dataflow + +CPU ↔ HW Accelerator ↔ CPU ↔ front-haul: for a set of consecutive PHY functions offload (e.g., FEC) + +CPU ↔ HW Accelerator ↔ CPU ↔ HW Accelerator ↔...↔ CPU ↔ front-haul: for a set of non-consecutive PHY functions offload + +#### Inline architecture user plane dataflow + +CPU ↔ HW Accelerator ↔ front-haul: for a set of consecutive PHY functions offload (up to the end of the PHY pipeline) + +Figure 5.1.8-2: illustrates one possible implementation of the look-aside and inline architectures. While a set of PHY-layer functions are offloaded to the HW Accelerator for look-aside acceleration, the entire end-to-end High-PHY pipeline is offloaded to the accelerator for inline acceleration. + +![Figure 5.1.8-2: User plane dataflow paths in look-aside and inline acceleration architectures. The diagram shows two main architectures: Look-Aside model and Inline model. In the Look-Aside model, O-DU L2+ PHY FH connects to L2 on CPU via L1/L2 Interface*. L2 on CPU connects to High Phy on CPU via L1/L2 Interface*. High Phy on CPU contains Func. 1, 3, 4, ..., n. High Phy on CPU connects to HW Accelerator via AAL Interface. HW Accelerator contains Func. 2 on accelerator and Func. N-1 on accelerator. HW Accelerator connects to O-RU via Front Haul Interface FH (7.2). In the Inline model, O-DU L2+ PHY FH connects to L2 on CPU via L1/L2 Interface*. L2 on CPU connects to High Phy on CPU via L1/L2 Interface*. High Phy on CPU contains Accelerator Interface on CPU. High Phy on CPU connects to HW Accelerator via AAL Interface. HW Accelerator contains Func. 2, 2, 3, ..., n-1, n. HW Accelerator connects to O-RU via Front Haul Interface FH (7.2). A legend indicates I/O data flow (double arrow), PHY downlink (red arrow), and PHY uplink (black arrow).](63722e07c40a795771d2b5eb1007d537_img.jpg) + +Look-Aside model + +Inline model + +O-DU L2+ PHY FH + +L2 on CPU + +L1/L2 Interface\* + +High Phy on CPU + +Func. 1 + +Func. 3 + +Func. 4 + +... + +Func. n + +AAL Interface + +Func. 2 on accelerator + +Func. N-1 on accelerator + +HW Accelerator + +Front Haul Interface FH (7.2) + +O-RU + +\*e.g. FAPI + +I/O data flow + +PHY downlink + +PHY uplink + +Figure 5.1.8-2: User plane dataflow paths in look-aside and inline acceleration architectures. The diagram shows two main architectures: Look-Aside model and Inline model. In the Look-Aside model, O-DU L2+ PHY FH connects to L2 on CPU via L1/L2 Interface\*. L2 on CPU connects to High Phy on CPU via L1/L2 Interface\*. High Phy on CPU contains Func. 1, 3, 4, ..., n. High Phy on CPU connects to HW Accelerator via AAL Interface. HW Accelerator contains Func. 2 on accelerator and Func. N-1 on accelerator. HW Accelerator connects to O-RU via Front Haul Interface FH (7.2). In the Inline model, O-DU L2+ PHY FH connects to L2 on CPU via L1/L2 Interface\*. L2 on CPU connects to High Phy on CPU via L1/L2 Interface\*. High Phy on CPU contains Accelerator Interface on CPU. High Phy on CPU connects to HW Accelerator via AAL Interface. HW Accelerator contains Func. 2, 2, 3, ..., n-1, n. HW Accelerator connects to O-RU via Front Haul Interface FH (7.2). A legend indicates I/O data flow (double arrow), PHY downlink (red arrow), and PHY uplink (black arrow). + +**Figure 5.1.8-2: User plane dataflow paths in look-aside and inline acceleration architectures.** + +### 5.1.9 AAL Application interface Concurrency and Parallelism + +To enable greater flexibility and design choice by AAL Application vendors, the AAL Application interface shall support multi-threading environment allowing an AAL Application to offload acceleration requests in parallel from several threads. + +### 5.1.10 Separation of Control and User Plane AAL Application interface APIs + +For efficiency and flexibility of AAL Implementation, AAL Application interface shall support separation of control and user plane APIs with appropriate identifiers, as required by different AAL profiles. + +### 5.1.11 Support of Versatile Acceleration Payload + +Range of payload sizes can vary widely, depending on the specific layer of the RAN protocol stack from which the workload for AAL profile(s) is offloaded to a HW Accelerator. AAL Application interface API shall be flexible to support various ranges of payload sizes as required by different AAL profiles. + +### 5.1.12 Support of Different Transport Mechanisms + +The transport between an AAL Application and an AAL Implementation can be of different types (e.g., based on shared memory, PCIe interconnect, over ethernet). The AAL Application interface shall support abstraction of these various transport mechanisms between the AAL Application and the AAL Implementation. + +### 5.1.13 AAL API namespace + +For convenience of AAL Implementation, the AAL shall follow a unique name space for all AAL API functions. + +### 5.1.14 Chaining of AAL Profiles + +AAL profiles specify one or multiple AFs in specific order offloaded to the HWA. To take advantage of multiple AFs offloaded to the same or different HWAs, the AAL Implementation can permit the chaining of AAL Profile(s) executing the AF or set thereof. In such a case, the AAL Implementation redirects the output of preceding AAL Profile as input to the subsequent AAL Profile belonging to the same or different LPU(s) on the same or different HWA(s). Such a chaining of AAL Profiles allows data to be transferred from one AAL Profile to another AAL Profile without the intervention of the AAL Application thereby reducing transfer latencies. Chained AAL Profile Instances can reside on the same or different LPUs and HWAs. However, in this version of specification, only considers the chaining of AAL Profiles on single AAL-LPU, and the HAM announces chained AAL Profiles which can be satisfied on the single AAL- LPU and HWA. Other cases where the chained AAL Profile straddles across multiple AAL-LPUs and HWAs are for further study. + +The use of chaining two AAL Profiles is optional for the AAL Implementation and depends on the AAL Profiles requested by the AAL Application. During CNF deployment as per K8s profile, or VNF deployment as per ETSI profile, AAL Implementation can chain the AAL Profiles to create a chained AAL Profile with more AFs implemented as part of the chained AAL Profile. The chained AAL Profile should conform to the AAL Profile requested by the AAL Application, i.e., the chained AAL Profile has same properties towards the AAL Application as well as the IMS and the DMS. It is the responsibility of the AAL Implementation to announce that the chained profile as an AAL Profile as defined in AAL specifications to which the chain conforms. The first AAL Profile in the chain takes data from the AAL Application and the last AAL Profile returns the transformed data to the AAL Application. + +A chained AAL Profile Instance is valid only if the two or more AAL Profiles form semantically correct sequence of consecutive blocks in the AF processing chain and no intervention is required by the AAL Application for control or data exchanged between the two AAL Profiles. Additionally, the output format of the preceding AAL Profile should match with the input format of the succeeding AAL Profile. + +AAL Profile chaining may be applicable to both inline and look-aside acceleration. The data flows in these cases are depicted in Figure 5.1.14-3: and Figure 5.1.14-4:. + +![Diagram illustrating data flow through unchained AAL Profiles. An AAL Application box at the top interacts with multiple AAL Profile Instance boxes (Instance 1, Instance 2, ..., Instance n) below it. Solid arrows show data flow from the AAL Application to each instance and back. A dashed arrow shows a direct return path from the AAL Application to the last instance.](b1459d87cd99cf742aab66c58a9fc00e_img.jpg) + +``` + +graph TD + AA[AAL Application] + IP1[AAL Profile Instance 1] + IP2[AAL Profile Instance 2] + IPn[AAL Profile Instance n] + + AA --> IP1 + IP1 --> AA + AA --> IP2 + IP2 --> AA + AA -.-> IPn + IPn --> AA + +``` + +Diagram illustrating data flow through unchained AAL Profiles. An AAL Application box at the top interacts with multiple AAL Profile Instance boxes (Instance 1, Instance 2, ..., Instance n) below it. Solid arrows show data flow from the AAL Application to each instance and back. A dashed arrow shows a direct return path from the AAL Application to the last instance. + +**Figure 5.1.14-1: Data flow through unchained AAL Profiles** + +![Diagram of AAL Application and AAL Chained Profile Instance](f5f7e673b788fc81825d475f36bf9acd_img.jpg) + +The diagram illustrates the architecture of AAL Profiles. At the top, a yellow box labeled 'AAL Application' is connected by a downward arrow to a dashed-line box labeled 'AAL Chained Profile Instance'. Inside this dashed box, three yellow boxes represent 'AAL Profile 1', 'AAL Profile 2', and 'AAL Profile n'. Arrows show a sequential flow from 'AAL Profile 1' to 'AAL Profile 2' and then to 'AAL Profile n'. A bidirectional arrow connects the 'AAL Application' box to the 'AAL Profile n' box, indicating a return path for data or control. + +Diagram of AAL Application and AAL Chained Profile Instance + +NOTE 1: In Figure 5.1.14-1 and Figure 5.1.14-2 above, the chained AAL Profile Instance is a data stream transformer that works upon the input data stream to produce output stream. Input data and parameters are passed on from preceding AAL Profile to next. These are provided by the AAL Application in case of the first AAL Profile. The difference is that in Figure 5.1.14-1, the AAL Application would call a series of AAL Profile Instances, while in **Error! Not a valid bookmark self-reference.**, the AAL Application calls only one AAL Profile Instance, which happens to be the chained AAL Profile instance. + +NOTE 2: The mechanisms for transfer of data and parameters to each of the AAL Profile Instances in unchained mode and to the chained AAL Profile Instances follow the AAL-C-App interface's transport as defined in AAL Common API Specifications [14]. The AAL Profiles in the chained mode shall continue to follow the AAL-C-App Interface specified in [14] + +NOTE 3: The AAL-Implementation can configure the chaining of AAL-Profiles during its initialization in order to avoid disruption in the processing chain while the AAL Application is in service. + +**Figure 5.1.14-2: Data flow through chained AAL Profiles** + +The chaining of AAL Profiles is possible across the HWAs and LPUs, however, it is beyond the current scope of document and for future studies. + +The chained look-aside acceleration architecture follows the same dataflow models as look-aside acceleration functions with subtle difference. The first and the last blocks in the chain interfacing the CPU to HW Accelerator support respectively dataflow from the CPU to the accelerator and then from accelerator back to the CPU. All the intermediate blocks support dataflow to and from the preceding and succeeding accelerated functions when those are configured as links in the chain. When not configured as chained accelerated functions, these should support dataflow as in look-aside acceleration. + +#### Look-aside chained architecture user plane dataflow. + +CPU ↔ HW Accelerator (AF1) ↔ HW Accelerator (AF2) ↔ ... ↔ HW Accelerator (AFn) ↔ CPU ↔ front-haul: for offload of a set of consecutive PHY functions (e.g., FEC) + +CPU ↔ HW Accelerator (AF1) ↔ ... ↔ HW Accelerator (AFn) ↔ CPU ↔ HW Accelerator ↔ ... ↔ CPU ↔ front-haul: for offload of a set of non-consecutive PHY functions + +Figure 5.1.14-3: illustrates the data flow through the chained HW Accelerated functions within an accelerator when configured for consecutive PHY function offload while Figure 5.1.14-4 represents it for non-consecutive PHY function offload. + +![Figure 5.1.14-3: Dataflow through chained lookaside HW Accelerator for consecutive Hi-PHY functions.](ac1df873c5c60114cd5ef7e209cb7dcd_img.jpg) + +The diagram illustrates the dataflow for consecutive Hi-PHY functions. On the left, a pink box labeled 'O-DU' contains 'L2+', 'PHY', and 'FH'. A bracket labeled 'Look-aside chaining Model' connects this to a dashed box. Inside the dashed box, 'L2+ on CPU' contains a yellow box 'L2'. A double-headed arrow labeled 'L1/L2 Interface\*' connects 'L2' to a large grey box 'High Phy on CPU'. Inside 'High Phy on CPU', there are yellow boxes 'Func. 1' and 'Func. n'. A horizontal bar labeled 'AAL Interface' is between them. Below 'High Phy on CPU' is a grey box 'HW Accelerator' containing yellow boxes 'Func. 2 on accelerator' and 'Func. N-1 on accelerator'. Red arrows show PHY downlink flow: from 'Func. 1' to 'Func. 2 on accelerator', and from 'Func. N-1 on accelerator' to 'Func. n'. Black arrows show PHY uplink flow: from 'Func. n' to 'Func. N-1 on accelerator', and from 'Func. 2 on accelerator' to 'Func. 1'. A double-headed arrow labeled 'I/O data flow' is at the bottom. On the right, a double-headed arrow labeled 'Front Haul Interface' connects the 'High Phy on CPU' box to a pink box 'O-RU' labeled 'FH (7.2)'. A legend at the bottom right shows a red arrow for 'PHY downlink' and a black arrow for 'PHY uplink'. + +Figure 5.1.14-3: Dataflow through chained lookaside HW Accelerator for consecutive Hi-PHY functions. + +**Figure 5.1.14-3: Dataflow through chained lookaside HW Accelerator for consecutive Hi-PHY functions.** + +![Figure 5.1.14-4: Dataflow through chained lookaside HW Accelerator for consecutive and non-consecutive PHY.](3aa4cd4077e12736b418ba70bf564c5c_img.jpg) + +The diagram illustrates the dataflow for consecutive and non-consecutive PHY functions. The structure is similar to Figure 5.1.14-3, but the 'HW Accelerator' box contains four yellow boxes: 'Func. 2', 'Func. 3', 'Func. 5', and 'Func. N-1'. Red arrows show PHY downlink flow: from 'Func. 1' to 'Func. 2', 'Func. 2' to 'Func. 3', 'Func. 3' to 'Func. 5', 'Func. 5' to 'Func. N-1', and 'Func. N-1' to 'Func. n'. Black arrows show PHY uplink flow: from 'Func. n' to 'Func. N-1', 'Func. N-1' to 'Func. 5', 'Func. 5' to 'Func. 3', 'Func. 3' to 'Func. 2', and 'Func. 2' to 'Func. 1'. The legend at the bottom right is the same as in Figure 5.1.14-3. + +Figure 5.1.14-4: Dataflow through chained lookaside HW Accelerator for consecutive and non-consecutive PHY. + +**Figure 5.1.14-4: Dataflow through chained lookaside HW Accelerator for consecutive and non-consecutive PHY.** + +## 5.2 High-PHY Profile Specific Principles + +The set of features of AAL described in the following subsections are relevant for inline High-PHY AAL profiles (profile names with suffix ‘\_HIGH-PHY’) defined in Chapter 5 + +### 5.2.1 Separation of Cell and Slot Level Parameter Configurations + +In general, “cell-specific” (typically static or semi-static in nature) parameters change less frequently than “slot-specific” (typically dynamic in nature, specific to PHY channels/signals) parameters associated with inline, High-PHY AAL profiles. Hence, for optimizing signalling overhead, the AAL Application interface shall support configuration of “cell-specific” and “slot-specific” parameters to the AAL Implementation using separate AAL Application interface API functions. It is noteworthy that the cell/slot specific configurations can include both control and user planes. + +### 5.2.2 SFN/slot-based Synchronization + +The AAL Application interface shall support system frame number (SFN) based or slot-based synchronization between the AAL Application and the AAL Implementation supporting inline, high-PHY AAL profiles. + +### 5.2.3 Compatibility with O-RAN FH interface + +The functional split between the O-DU and the O-RU remains as defined by the WG4 OFH interface [17] and the AAL Application interface API shall be compatible with O-RAN FH interface (7.2-x split) to enable communication between the O-DU AAL Application and O-RU via AAL Implementation as required by inline, High-PHY AAL profile(s). + +### 5.2.4 Inline Profile for High-PHY Stack + +Inline data flow for the AAL Profile that specifies a complete stack of High-PHY functions implies that the set of Accelerated Functions is constituted by the entire U-plane processing of the High-PHY channels or signals (with 7-2x PHY functional split) and the IQ data (in DL) or decoded bits (in UL) (post processing) and these are transferred directly from the HW Accelerator to the Fronthaul interface (in DL) or to the Layer 2 (in UL). + +Inline acceleration for AAL Profiles that specify a partial stack of the High-PHY for UL and for DL Accelerated Functions is also possible; in such case only parts of the U-Plane, i.e., not all the functions of the High-PHY stack of a given channel, may be offloaded to a HW Accelerator. For inline acceleration of a partial High-PHY stack, the IQ data or decoded bits are also transferred directly from the HW Accelerator to the Fronthaul (in DL) and to the non-accelerated part of the High-PHY stack (in UL). The set of Accelerated Functions that are offloaded in Inline mode for acceleration of a partial High-PHY stack would be AAL Profile specific. The support of AAL Profiles that specify the support of partial High-PHY stack is for future study. + +![Figure 5.2.4-1: Partial Inline Model for AAL Hi-PHY Profile. The diagram illustrates the data flow between the O-DU, L2+ on CPU, High Phy on CPU, HW Accelerator, and O-RU. The O-DU (L2+, PHY, FH) connects to the L2+ on CPU via an L1/L2 Interface*. The L2+ on CPU connects to the High Phy on CPU via an L1/L2 Interface*. The High Phy on CPU contains Func. 1, Func. 2, and Func. n. The HW Accelerator contains Func. 3, Func. 4, and Func. N-1. An AAL Interface connects the High Phy on CPU to the HW Accelerator. The HW Accelerator connects to the O-RU via a Front Haul Interface (FH (7.2)). Red arrows indicate PHY downlink flow, and black arrows indicate PHY uplink flow. A legend at the bottom shows I/O data flow with a double-headed arrow and PHY downlink/uplink with single-headed arrows.](445ce018fc60b589e6fb221505024dae_img.jpg) + +Figure 5.2.4-1: Partial Inline Model for AAL Hi-PHY Profile. The diagram illustrates the data flow between the O-DU, L2+ on CPU, High Phy on CPU, HW Accelerator, and O-RU. The O-DU (L2+, PHY, FH) connects to the L2+ on CPU via an L1/L2 Interface\*. The L2+ on CPU connects to the High Phy on CPU via an L1/L2 Interface\*. The High Phy on CPU contains Func. 1, Func. 2, and Func. n. The HW Accelerator contains Func. 3, Func. 4, and Func. N-1. An AAL Interface connects the High Phy on CPU to the HW Accelerator. The HW Accelerator connects to the O-RU via a Front Haul Interface (FH (7.2)). Red arrows indicate PHY downlink flow, and black arrows indicate PHY uplink flow. A legend at the bottom shows I/O data flow with a double-headed arrow and PHY downlink/uplink with single-headed arrows. + +Figure 5.2.4-1: Partial Inline Model for AAL Hi-PHY Profile + +# 6. AAL-LPU Principles + +## 6.1 Overview + +This section discusses about AAL-LPU(s) presented to AAL Applications using the AAL Application interface. An AAL-LPU should not be confused with a physical HW Accelerator. Within a process address space each AAL-LPU shall abstract the AAL Application from underlying HW Accelerator. + +The following list provides a description of capabilities and characteristics of AAL-LPUs: + +- An AAL-LPU maps to a single HW Accelerator. An AAL-LPU can be identified uniquely within a HW Accelerator. +- A HW Accelerator may support 1 to N AAL-LPU's. +- Each AAL-LPU shares the resources of the associated HW Accelerator with other AAL-LPU(s) mapped to the same HW Accelerator. AAL-LPU can also represent a hard partition of the HW Accelerator where resources are dedicated to the partition. +- Mapping of HW Accelerator resources to AAL-LPU shall be configurable from O2 interface +- An AAL-LPU may support more than one AAL profile. For each supported AAL profile, an AAL-LPU may execute 0 to N AAL-Profile-Instances. +- An AAL-LPU can be assigned to a single POD or VM. Multiple LPU's can be assigned to a POD or VM. +- An AAL-LPU can provide service to 0 or more AAL Applications within a POD or VM. +- AAL-LPU is a virtual Managed Element as defined in [13]. + +Depending on HW design and implementation choice, a HW Accelerator may accelerate multiple profiles or offer support for sharing HW Accelerator resources between multiple threads, processes, VMs, PODs. For this reason, a second abstract construct known as AAL Profile Queue can optionally be used to + +- distinguish between multiple supported AAL profiles per AAL-LPU +- prioritize access to AAL-LPU resources +- group operation requests +- allow parallel access through AAL Application interface for multiple threads + +As an abstract construct, an AAL Profile Queue does not reflect a HW design specification or requirement. + +From the AAL Application point of view, an AAL Profile queue is exposed by an AAL Profile Instance + +- an AAL Profiles Instances exposes one or more AAL Profile Queues +- The AAL Profile Queue optionally also supports priority, allowing the AAL Application to schedule jobs of different priorities. + +NOTE: An AAL Profile Queue can be used by an AAL Application to share AAL-LPU resources between threads/cores belonging to the same process address space + +NOTE: An AAL Application may use multiple AAL Profile Queues to access different AAL Profile Instances supported by an AAL-LPU + +## 6.2 LPU Deployment and Operation + +### 6.2.1 Example AAL-LPU Mapping + +The following Section contains example deployments mapping AAL-LPUs to AAL Applications. The labels ‘profile-instanceID’ and ‘queueID’ in the following diagrams denote AAL Profile Instance object handle and identifier of an AAL Profile Queue respectively. + +- **Scenario 1: Basic implementation:** A HW Accelerator supports a single AAL-LPU which exposes a single AAL-Profile-Instance for one AAL Application to use + +![Diagram illustrating Scenario 1: Basic implementation. An AAL Application (API(profile-instanceID, queueID)) is connected to an AAL Profile Instance, which is connected to AAL-LPU0, which is connected to a HW Accelerator (Physical).](b572d8c7d42c86287763f9810594cf7c_img.jpg) + +``` + +graph TD + subgraph AAL_Application [AAL Application] + API[API(profile-instanceID, queueID)] + API --- AAL_Profile_Instance[AAL Profile Instance] + end + AAL_Profile_Instance <--> AAL_LPU0[AAL-LPU0] + AAL_LPU0 <--> HW_Accelerator[HW Accelerator (Physical)] + +``` + +Diagram illustrating Scenario 1: Basic implementation. An AAL Application (API(profile-instanceID, queueID)) is connected to an AAL Profile Instance, which is connected to AAL-LPU0, which is connected to a HW Accelerator (Physical). + +A HW Accelerator supports a single AAL LPU which exposes a single AAL Profile Queue for one application to use + +**Figure 6.2.1-1: Scenario 1: A single AAL LPU exposes a single AAL Profile Queue used by a single AAL Application.** + +**Scenario 2: Basic Multi Application Support:** A HW Accelerator supports multiple AAL LPUs for multiple AAL Applications + +![Diagram showing two AAL Applications, each containing an AAL Profile Instance and an AAL-LPU0, connected to a single HW Accelerator (Physical).](b3340bb90cba9e433238521218898503_img.jpg) + +The diagram illustrates a multi-application support scenario. It features two identical AAL Application blocks side-by-side. Each block contains an API(profile-instanceID, queueID) at the top, followed by an AAL Profile Instance, and then an AAL-LPU0 at the bottom. Arrows indicate bidirectional communication between the API and the AAL Profile Instance, and between the AAL Profile Instance and the AAL-LPU0. Both AAL-LPU0 components are connected via bidirectional arrows to a single HW Accelerator (Physical) block located at the bottom. + +Diagram showing two AAL Applications, each containing an AAL Profile Instance and an AAL-LPU0, connected to a single HW Accelerator (Physical). + +**Multi application support** +Example showing multiple applications supported by a single HW accelerator + +**Figure 6.2.1-2: A single HW Accelerator supporting two LPU's each assigned to individual AAL Applications** + +- **Scenario 3: Multiple Accelerator Support:** Mapping example showing multiple HW Accelerators assigned to a single AAL Application + +![Diagram showing a single AAL Application containing two AAL Profile Instances and two AAL-LPU0/AAL-LPU1 components, each connected to a separate HW Accelerator (Physical).](de329a5fb451359c8f0050ce690fa4f2_img.jpg) + +The diagram illustrates a multi-accelerator support scenario. A single AAL Application block is shown, containing two API(profile-instanceID, queueID) at the top. Below each API is an AAL Profile Instance, and below each AAL Profile Instance is an AAL-LPU0 and an AAL-LPU1 respectively. Arrows indicate bidirectional communication between the API and the AAL Profile Instance, and between the AAL Profile Instance and the AAL-LPU0/AAL-LPU1. Each AAL-LPU0 and AAL-LPU1 component is connected via bidirectional arrows to its own separate HW Accelerator (Physical) block located at the bottom. + +Diagram showing a single AAL Application containing two AAL Profile Instances and two AAL-LPU0/AAL-LPU1 components, each connected to a separate HW Accelerator (Physical). + +**Multi accelerator support** +Example showing multiple HW accelerators assigned to a single application + +**Figure 6.2.1-3: Two HW Accelerators each supporting a single AAL-LPU assigned to a single AAL Application.** + +- **Scenario 4: Multi Queue Support:** AAL LPU mapping showing multiple AAL Profile Queue support + +![Figure 6.2.1-4: A single AAL LPU exposes two AAL Profile Queues used by a single AAL Application. The diagram shows an AAL Application box containing an AAL Profile Instance box and an AAL-LPU0 box. The AAL Profile Instance box is connected to the AAL-LPU0 box by a double-headed arrow. The AAL Application box is connected to a HW Accelerator (Physical) box by a double-headed arrow. The AAL Application box also contains two vertical queues, each with four small squares, representing AAL Profile Queues.](d1ee69fc6f80df98aab4bee4509bb3ba_img.jpg) + +Figure 6.2.1-4: A single AAL LPU exposes two AAL Profile Queues used by a single AAL Application. The diagram shows an AAL Application box containing an AAL Profile Instance box and an AAL-LPU0 box. The AAL Profile Instance box is connected to the AAL-LPU0 box by a double-headed arrow. The AAL Application box is connected to a HW Accelerator (Physical) box by a double-headed arrow. The AAL Application box also contains two vertical queues, each with four small squares, representing AAL Profile Queues. + +**Multi queue support** +A single AAL LPU exposes +two AAL Profile Queues +used by a single AAL +Application + +**Figure 6.2.1-4: A single AAL LPU exposes two AAL Profile Queues used by a single AAL Application.** + +- **Scenario 5: Multi Profile Support:** Mapping example showing multi-function support + +![Figure 6.2.1-5: A single AAL LPU supporting two AAL Profile Instances exposes two AAL Profile Queues used by a single AAL Application. The diagram shows an AAL Application box containing two AAL Profile Instance boxes and one AAL-LPU0 box. Each AAL Profile Instance box is connected to the AAL-LPU0 box by a double-headed arrow. The AAL Application box is connected to a HW Accelerator (Physical) box by a double-headed arrow. The AAL Application box also contains two vertical queues, each with four small squares, representing AAL Profile Queues.](e14133d8413be822c4cf5e9d9fa1680f_img.jpg) + +Figure 6.2.1-5: A single AAL LPU supporting two AAL Profile Instances exposes two AAL Profile Queues used by a single AAL Application. The diagram shows an AAL Application box containing two AAL Profile Instance boxes and one AAL-LPU0 box. Each AAL Profile Instance box is connected to the AAL-LPU0 box by a double-headed arrow. The AAL Application box is connected to a HW Accelerator (Physical) box by a double-headed arrow. The AAL Application box also contains two vertical queues, each with four small squares, representing AAL Profile Queues. + +**Multi Profile Support** +A single AAL LPU supporting two AAL Profile +Instances exposes two AAL Profile Queues used +by a single AAL Application + +**Figure 6.2.1-5: A single AAL LPU supporting two AAL Profile Instances exposes two AAL Profile Queues used by a single AAL Application.** + +- **Scenario 6: Chained Profile Support:** Mapping example showing a multi-profile chained AAL Profile Instance on an AAL-LPU + +![Diagram illustrating AAL-LPU Mapping example showing chained profile support. The diagram shows an AAL Application box containing an API(profile-instanceID, queueID) interface, a vertical stack of three small squares, and an AAL Chained Profile Instance box. The AAL Chained Profile Instance box contains AAL Profile 1 and AAL Profile 2, connected by a right-pointing arrow. Below the AAL Chained Profile Instance box is an AAL-LPU0 box, connected by a double-headed vertical arrow. Below the AAL-LPU0 box is a HW Accelerator (Physical) box, also connected by a double-headed vertical arrow.](722fb847287bcec6fa8a7313bd7f3d25_img.jpg) + +Diagram illustrating AAL-LPU Mapping example showing chained profile support. The diagram shows an AAL Application box containing an API(profile-instanceID, queueID) interface, a vertical stack of three small squares, and an AAL Chained Profile Instance box. The AAL Chained Profile Instance box contains AAL Profile 1 and AAL Profile 2, connected by a right-pointing arrow. Below the AAL Chained Profile Instance box is an AAL-LPU0 box, connected by a double-headed vertical arrow. Below the AAL-LPU0 box is a HW Accelerator (Physical) box, also connected by a double-headed vertical arrow. + +#### Chained Profile Support + +Example showing multiple AAL Profiles (1 & 2) chained together to implement a single AAL Profile Instance on an AAL-LPU which is equivalent to Profile 1 + Profile 2 + +**Figure 6.2.1-6: AAL-LPU Mapping example showing chained profile support** + +### 6.2.2 Statistics + +The AAL Application interface shall provide an AAL Application with general statistics upon request. Statistics may include but not limited to operation counts and error counts. + +### 6.2.3 Memory Management + +O-RAN network functions (O-DU, O-CU, etc.) will be responsible for input, output and operation structure memory allocation and freeing, using AAL defined memory management functions. All other AAL Application memory is not required to use the AAL memory management functions. + +Device Drivers are free to manage their own internal memory, DMA implementation as needed, the AAL specification does not add any memory requirements to device driver. + +Each AAL Implementation shall define its own memory requirements and implement its own memory backing if needed. + +Each AAL Implementation may define its own operation memory structure and allocation if needed. + +### 6.2.4 Run Time Configurations + +Operations are requested to the AAL-LPU to execute specific HW Accelerated Function(s). Each operation shall be represented by an operation struct that shall define all necessary metadata, configurations and information required for the operation to be processed on an AAL-LPU. The operation structs shall define the operation type to be performed, including an operation status and reference to the AAL profile specific operation data which can vary in size and content depending on the AAL profile. Each AAL profile shall define its own operation structure for its specific functions. + +### 6.2.5 AAL Profile(s) offload, processing status query and processed data retrieval + +#### 6.2.5.1 Overview + +An AAL Application aggregates one or more AAL profile(s) and offload to the AAL Implementation using a single AAL Application interface API invocation. As one example, for High-PHY AAL profiles defined in clause 7, multiple AAL profiles (where an AAL profile refers to a PHY channel/signal for one or more than one cell(s) and one or more than one UE(s)) scheduled within a slot can be aggregated and offloaded to an AAL-LPU by the AAL Application using a single AAL Application interface API invocation. + +The processing status of offloaded/enqueued AAL profile(s) can be queried by the AAL Application in an ‘asynchronous’ manner, i.e., not necessarily in the same order in which the AAL profile(s) are offloaded. In case the AAL Application retrieves the post-processed data from the AAL Implementation, a ‘processing status query’ request can be bundled with a ‘processed data retrieval/dequeue’ request. In general, status query and dequeue request corresponding to multiple enqueue requests can be bundled together by the AAL Application and invoked through a single AAL Application interface API function. + +#### 6.2.5.2 AAL Profile Functionality Bypass + +An AAL Profile specifies a series of one or more Accelerated Functions (AFs) which can be offloaded to Hardware Accelerator by the AAL Application. These AFs are linked internally and interface to each other in a manner transparent to the AAL Application. However, under certain situations, it is desirable to bypass certain AFs implemented by the AAL Profile. For example, consider an AAL Profile that has 3 AFs as shown in Figure-6.2.5.1-1 (a) below. With bypass mode, it is possible to get functionalities in (b), (c), (d), (e), (f) and (g). + +![Figure 6.2.5.1-1: Various AAL Bypass scenarios. The diagram shows seven scenarios (a) through (g) for an AAL profile with three Accelerated Functions (AF1, AF2, AF3). In all scenarios, data flows from the AAL Application to the AFs and then to the AAL Application or NIC. (a) shows the full chain: AF1 -> AF2 -> AF3. (b) shows AF1 and AF2, with AF3 bypassed. (c) shows only AF1, with AF2 and AF3 bypassed. (d) shows AF2 and AF3, with AF1 bypassed. (e) shows only AF3, with AF1 and AF2 bypassed. (f) shows AF1 and AF3, with AF2 bypassed. (g) shows only AF2, with AF1 and AF3 bypassed.](305f671e59ed4f84345c3f5fdf0e2630_img.jpg) + +Figure 6.2.5.1-1: Various AAL Bypass scenarios. The diagram shows seven scenarios (a) through (g) for an AAL profile with three Accelerated Functions (AF1, AF2, AF3). In all scenarios, data flows from the AAL Application to the AFs and then to the AAL Application or NIC. (a) shows the full chain: AF1 -> AF2 -> AF3. (b) shows AF1 and AF2, with AF3 bypassed. (c) shows only AF1, with AF2 and AF3 bypassed. (d) shows AF2 and AF3, with AF1 bypassed. (e) shows only AF3, with AF1 and AF2 bypassed. (f) shows AF1 and AF3, with AF2 bypassed. (g) shows only AF2, with AF1 and AF3 bypassed. + +**Figure 6.2.5.1- 1 Various AAL Bypass scenarios** + +Any AF in the set of processing functions may be bypassed as long as the processing chain of the AAL Profile remains unaffected. Bypass modes apply to both inline and look-aside accelerators. + +The capability of the AAL Profile to support bypassing of certain AFs (“bypass mode” of operation) and the list of AFs which can be bypassed is advertised by the LPU. The AAL Profile definition shall continue to include all the mandatory accelerated functions that need to be supported by the vendors to comply with the O-RAN profile specification. + +### 6.2.6 AAL-LPU Exposure + +#### 6.2.6.1 Overview + +After using the HW Accelerator Manager to create the AAL-LPU(s) and the profiles supported, we can then expose it to the AAL Application (e.g. in Kubernetes® it will be part of the POD environment variables). The goal of this section is to abstract the way the AAL-LPU and its supported profiles are exposed to the AAL Application in order to achieve AAL Application portability. Hence, the AAL-LPU and its profile(s) shall be exposed the AAL Application in an abstracted descriptor. + +As of today many implementations refer to the AAL-LPU by its PCI address and describe a single profile for the entire HW Accelerator, meaning exposure of one single profile for all LPUs supported. This section provides step-by-step example that shows how the AAL-LPU could be exposed to abstract the PCIe address and the profile(s) supported by + +the AAL-LPU. Although the below example is a Kubernetes® example, the outcome of it is independent of orchestration technology supported. + +#### 6.2.6.2 Example + +##### 6.2.6.2.1 AAL-LPU Configuration + +1. A given HW Accelerator can support 16 AAL-LPUs and FEC LDPC, PHY profiles but the default setup of the AAL-LPUs is FEC: + +![Diagram showing 16 AAL-LPUs (LPU-1 to LPU-16) all configured with FEC, connected to a HW Accelerator (Physical).](d4d9ae3b65bcaae8a97e03a99dfb422b_img.jpg) + +The diagram shows a row of 16 yellow boxes, each labeled 'LPU-1 FEC', 'LPU-2 FEC', 'LPU-3 FEC', followed by an ellipsis, and then 'LPU-16 FEC'. Below this row is a grey box labeled 'HW Accelerator (Physical)'. + +Diagram showing 16 AAL-LPUs (LPU-1 to LPU-16) all configured with FEC, connected to a HW Accelerator (Physical). + +**Figure 6.2.6.2.1-1: Example AAL-LPU and profile supported** + +2. Now assume HW Accelerator Manager configured the HW Accelerator as follow: + +- LPU-1 supports FEC version 01, PHY and LDPC version 01 profiles +- LPU-2 supports LDPC version 02 profile +- LPU-3 supports LDPC version 02 profile +- LPU-4 supports LDPC version 02 profile + +![Diagram showing 4 AAL-LPUs (LPU-1 to LPU-4) with specific profiles, connected to a HW Accelerator (Physical).](30467bcdb4ab509953319f4d3e925239_img.jpg) + +The diagram shows a row of 4 yellow boxes. The first box is labeled 'LPU-1 FECv01 & PHY & LDPCv01'. The next three boxes are labeled 'LPU-2 LDPCv02', 'LPU-3 LDPCv02', and 'LPU-4 LDPCv02'. Below this row is a grey box labeled 'HW Accelerator (Physical)'. + +Diagram showing 4 AAL-LPUs (LPU-1 to LPU-4) with specific profiles, connected to a HW Accelerator (Physical). + +**Figure 6.2.6.2.1-2: Example HW Accelerator configuration** + +3. Assigning it to a vDU POD and exposing the two LPU/Profiles needed by vDU (in green): + +![Diagram showing the assignment of AAL-LPUs and supported profiles to a POD. It includes a Manifest, POD environment variables, and the resulting LPU configuration.](5ddb688513464b42be655923b0a9a1b4_img.jpg) + +The diagram illustrates the process of assigning AAL-LPUs and supported profiles to a POD. It starts with a 'Manifest' box containing a YAML snippet: + + +``` +.. +resources: + requests: + memory: 4Gi + .. + /FECv01&PHY&LDPCv01 1 + /LDPCv02 2 +.. +``` + + The 'resources' section is highlighted in green. An arrow labeled 'after K8s POD creation' points from the Manifest to a 'POD environment variables' box. This box contains: + + +``` +#env +/(LPU1Address)/FECv01&PHY&LDPCv01 +/(LPU2 Address)/LDPCv02 +/(LPU3 Address)/LDPCv02 +.. +``` + + An arrow points from the 'POD environment variables' box to a final configuration box showing three yellow boxes: 'LPU-1 FECv01 & PHY & LDPCv01', 'LPU-2 LDPCv02', and 'LPU-3 LDPCv02'. Below these is a grey box labeled 'HW Accelerator (Physical)'. A blue arrow points from the 'POD environment variables' box to this final configuration box. A callout box labeled 'How many LPUs of a kind are requested' points to the numbers '1' and '2' in the Manifest. + +Diagram showing the assignment of AAL-LPUs and supported profiles to a POD. It includes a Manifest, POD environment variables, and the resulting LPU configuration. + +**Figure 6.2.6.2.1-3: Example assignment of AAL-LPUs and supported profiles to POD** + +We can see that the AAL-LPU resources requested in the manifest is translated in the POD environment to three AAL-LPU addresses plus the strings that describe the profiles supported by the LPU. Please note that the AAL Application will be able to query the AAL-LPUs and their supported profiles via the AAL-C-App API. + +##### 6.2.6.2.2 AAL-LPU Control by the AAL Application + +The figure below shows how the AAL Application for a vDU can create several PHY profiles on LPU-1, for example, PHY Profile-1 handles cell-1 and PHY Profile-2 handles cell-2, as well as running different LDPC profiles on different LPUs and all in the same HW Accelerator. As mentioned before the AAL Application can query what profiles supported by reading the POD environment variables or by querying it using the AAL-C-App API. + +![Diagram showing AAL Application configured AAL-Profile-Instances. It illustrates three LPUs (LPU-1, LPU-2, LPU-3) connected to a HW Accelerator (Physical). Above the LPUs, several profile instances are listed: FECv01 Profile Instance 1, FECv02 Profile Instance 1, PHY Profile Instance 1, PHY Profile Instance 2, LDPCv02 Profile Instance 1, and LDPCv02 Profile Instance 1. A callout box points to the first two instances, stating: 'The numbers represent an application perspective (e.g. handlers)'.](c78cc0b7b3fd41cb118b11ef3c94d045_img.jpg) + +The numbers represent an application perspective (e.g. handlers) + +FECv01 Profile Instance 1 +FECv02 Profile Instance 1 +PHY Profile Instance 1 +PHY Profile Instance 2 +LDPCv02 Profile Instance 1 +LDPCv02 Profile Instance 1 + +LPU-1 LPU-2 LPU-3 + +HW Accelerator (Physical) + +Diagram showing AAL Application configured AAL-Profile-Instances. It illustrates three LPUs (LPU-1, LPU-2, LPU-3) connected to a HW Accelerator (Physical). Above the LPUs, several profile instances are listed: FECv01 Profile Instance 1, FECv02 Profile Instance 1, PHY Profile Instance 1, PHY Profile Instance 2, LDPCv02 Profile Instance 1, and LDPCv02 Profile Instance 1. A callout box points to the first two instances, stating: 'The numbers represent an application perspective (e.g. handlers)'. + +**Figure 6.2.6.2.2-1: Example AAL Application configured AAL-Profile-Instances** + +##### 6.2.6.2.3 AAL-LPU resource tracking + +It is a key to be able to track the AAL-LPU as a resource for providing the AAL Application with acceleration resources it needs otherwise the attempt to create the NF will fail due to insufficient resources available. + +There are few notes related to the tracking of the AAL-LPU resources in relation to the example's above in : + +- If another POD needs to use the LDPC profile, Kubernetes will allow it as 2 out of 3 were used (LPU-4 supports it). +- If another POD needs to use FEC and PHY profiles (FEC&PHY), Kubernetes will reject it as only one LPU is configured this way. +- We need to consider if a logic is needed to track the AAL-LPU availability from the SMO. For example, a total of ten AAL-LPU/FEC profiles available in a cluster, three is being used by a deployment, seven left for a new deployment. The seven available could be revealed to the user or automation at the SMO level when considering additional deployments. + +The conclusion is that the SMO shall be able to track the AAL-LPU as a resource and its availability. + +### 6.2.7 Accelerator configuration options between IMS & FOCOM + +#### 6.2.7.1 Declarative approach + +Declarative approach defines a desired system state and software is responsible for bringing the system to that state. In context of accelerator management, it is the desired state of the accelerator configuration to support certain profile(s) characteristics. This approach is flexible, reliable and repeatable, reducing or eliminating the need for imperative deployment techniques such as scripting and manual command entry. The O-RAN WG6 O2 General Aspects and Principles [11] clause 3.4.3.8 discusses the Cluster Template concept that this supports. + +The following are examples of a desired state for an accelerator to support an AAL-Profile version 1.9.0 with two LPUs. + +##### Example profile centric + +``` + +... + +Profile_Name: AAL-PROFILE + +{ + Profile_Version: 1.9.0 + LPUs_Request: 2 +} + +... + +``` + +Or + +##### Example LPU Centric + +``` + +... + +LPUs_Request: 2 + +{ + Profile_Name: AAL-PROFILE + Profile_Version: 1.9.0 +} + +``` + +NOTE 1: The SMO represented Cluster Template instance characteristics such as Capabilities and Capacities are not described in the present document. + +# 7. AAL Profiles + +An AAL profile specifies a set of Accelerated Functions that a Hardware Accelerator processes on behalf of an AAL Application within an O-RAN Cloudified Network Function (e.g. O-DU, O-CU etc.). Accordingly, AAL profiles can be categorized as O-DU AAL profiles, O-CU AAL profiles and so on. The following sections describe these different AAL profile categories in further details. + +## 7.1 O-DU AAL Profiles + +An O-DU AAL profile can specify a set of Accelerated Functions within the O-DU protocol stack. These functions may belong to a single layer (e.g., PHY) or span across multiple layers (e.g., PHY and MAC) within O-DU. The current O-DU AAL profiles being studied by O-RAN WG6 are focusing on Accelerated Functions from PHY layer of O-DU. + +### 7.1.1 O-DU Protocol Stack Reference + +Figure 7.1.1-1: illustrates the building blocks for processing various O-DU PHY layer Downlink (DL) channels and signals (with 7.2-x functional split between O-DU and O-RU) defined by 3GPP in [6] & [7] as part of 5G NR specification. + +![Figure 7.1.1-1: O-DU PHY processing blocks for 5G NR Downlink. The diagram shows the processing flow for four channels: PDSCH TB(s), PBCH TB, PDCCH (DCI), and PSS/SSS. Each channel has a specific sequence of processing blocks. PDSCH TB(s) includes TB CRC attachment, CB segmentation + CB CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. PBCH TB includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, Modulation (QPSK), and RE mapping. PDCCH (DCI) includes CRC attachment, Polar encoding, Rate matching, Scrambling, Modulation (QPSK), and RE mapping. PSS/SSS includes Sequence generation, Modulation, and RE mapping. All channels share a common precoding and IQ compression block. The diagram is organized into columns for each channel and rows for the processing blocks. A dashed box indicates the precoding and IQ compression blocks are shared across all channels. The bottom of the diagram is labeled 'O-RAN FH (7-2x lower layer split)'.](43cf35939eea6a924b51be1f1b604d7b_img.jpg) + +| L2+ | | | | | | | +|-------------------------------------|--|---------------------|--|-------------------------|--|-------------------------| +| <b>PDSCH TB(s)</b> | | <b>PDCCH (DCI)</b> | | <b>PBCH TB</b> | | | +| TB CRC attachment | | CRC attachment | | PBCH payload generation | | | +| CB segmentation + CB CRC attachment | | Polar encoding | | Scrambling | | | +| LDPC encoding | | Rate matching | | TB CRC attachment | | | +| Rate matching | | Scrambling | | Polar encoding | | | +| CB concatenation | | Modulation (QPSK) | | Rate matching | | | +| Scrambling | | Modulation | | Data scrambling | | <b>PSS/SSS</b> | +| Modulation | | Modulation | | Modulation (QPSK) | | <b>PBCH DM-RS</b> | +| Layer mapping | | Modulation | | Modulation | | <b>CSI-RS/PT-RS/TRS</b> | +| Modulation | | Modulation | | Modulation | | | +| Sequence generation | | Sequence generation | | Sequence Generation | | | +| Modulation | | Modulation | | Modulation | | | +| Precoding* | | Precoding* | | Precoding* | | | +| RE mapping | | RE mapping | | RE mapping | | | +| IQ compression* | | IQ compression* | | IQ compression* | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | + +Figure 7.1.1-1: O-DU PHY processing blocks for 5G NR Downlink. The diagram shows the processing flow for four channels: PDSCH TB(s), PBCH TB, PDCCH (DCI), and PSS/SSS. Each channel has a specific sequence of processing blocks. PDSCH TB(s) includes TB CRC attachment, CB segmentation + CB CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. PBCH TB includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, Modulation (QPSK), and RE mapping. PDCCH (DCI) includes CRC attachment, Polar encoding, Rate matching, Scrambling, Modulation (QPSK), and RE mapping. PSS/SSS includes Sequence generation, Modulation, and RE mapping. All channels share a common precoding and IQ compression block. The diagram is organized into columns for each channel and rows for the processing blocks. A dashed box indicates the precoding and IQ compression blocks are shared across all channels. The bottom of the diagram is labeled 'O-RAN FH (7-2x lower layer split)'. + +**Figure 7.1.1-1: O-DU PHY processing blocks for 5G NR Downlink** + +The O-DU PHY layer in downlink consists of the following physical channels and reference signals: + +- Physical Downlink Shared Channel (PDSCH) and associated Demodulation Reference Signal (PDSCH DM-RS). +- Physical Downlink Control Channel (PDCCH) and associated Demodulation Reference Signal (PDCCH DM-RS). +- Synchronization Signal Block (SSB) consisting of + - Physical Broadcast Channel (PBCH) and associated DMRS (PBCH DM-RS). + - Primary Synchronization Signal (PSS). + - Secondary Synchronization Signal (SSS). + +- Channel State Information-Reference Signal (CSI-RS) and Tracking Reference Signal (TRS). + - Phase Tracking Reference Signal (PT-RS) for DL. +- The downlink physical channels (PDSCH, PDCCH, PBCH) carry information originating from higher layers (i.e. layer 2 and above). +- The downlink physical layer processing of data channel (PDSCH) carrying transport blocks consists of the following steps: +- TB CRC attachment: Error detection is provided on each transport block (TB) through a Cyclic Redundancy Check (CRC). Refer to Subclause 7.2.1 in [7] for details. + - CB segmentation and CRC attachment: The transport block is segmented when it exceeds the code block (CB) size specified by 3GPP [7]. Code block segmentation and code block CRC attachment are performed according to Subclauses 7.2.3 and 5.2.2 of [7]. + - LDPC encoding: Refer to Subclauses 7.2.4 and 5.3.2 in [7] for details. + - Rate matching: Refer to Subclauses 7.2.5 and 5.4.2 in [7] for details. + - CB concatenation: Refer to Subclauses 7.2.6 and 5.5 in [7] for details. + - Scrambling: Refer to Subclause 7.3.1.1 in [6] for details. + - Modulation: Refer to Subclause 7.3.1.2 in [6] for details. + - Layer mapping: Refer to Subclause 7.3.1.3 in [6] for details. + - RE mapping: Refer to Subclause 7.3.1.5 and 7.3.1.6 in [6] for details on Resource Element (RE) mapping. +- The downlink physical layer processing of control channel (PDCCH) carrying Downlink Control Information (DCI) consists of the following steps: +- CRC attachment: Error detection is provided on DCI transmissions through a Cyclic Redundancy Check (CRC). Refer to Subclause 7.3.2 in [7] for details. + - Polar encoding: Refer to Subclauses 7.3.3 and 5.3.1 in [7] for details. + - Rate matching: Refer to Subclauses 7.3.4 and 5.4.1 in [7] for details. + - Scrambling: Refer to Subclause 7.3.2.3 in [6] for details. + - Modulation: Refer to Subclause 7.3.2.4 in [6] for details. + - RE mapping: Refer to Subclause 7.3.2.5 in [6] for details. +- The downlink physical layer processing of broadcast channel (PBCH) carrying maximum one transport block consists of the following steps: +- PBCH payload generation: Refer to Subclause 7.1.1 in [7] for details. + - Scrambling: Refer to Subclause 7.1.2 in [7] for details. + - TB CRC attachment: Refer to Subclause 7.1.3 in [7] for details. + - Polar encoding: Refer to Subclauses 7.1.4 and 5.3.1 in [7] for details. + - Rate matching: Refer to Subclauses 7.1.5 and 5.4.1 in [7] for details. + - Data scrambling: Refer to Subclause 7.3.3.1 in [6] for details. + - Modulation: Refer to Subclause 7.3.3.2 in [6] for details. + - RE mapping: Refer to Subclause 7.3.3.3 in [6] for details. + +The downlink physical signals (DM-RS, PSS, SSS, CSI-RS/TRS, PT-RS) correspond to a set of resource elements used by the physical layer but does not carry information originated from higher layers (i.e. layer 2 and above). + +Reference Signals (DM-RS, CSI-RS/TRS, PT-RS) and Synchronization Signals (PSS/SSS) are generated using the following steps: + +Sequence Generation and Modulation: Refer to Subclauses 7.4.1.1.1 (PDSCH DM-RS), 7.4.1.3.1 (PDCCH DM-RS), 7.4.1.4.1 (PBCH DM-RS), 7.4.1.5.2 (CSI-RS/TRS), 7.4.1.2.1 (PT-RS), 7.4.2.2.1 (PSS) and 7.4.2.3.1 (SSS) in [6] for details. + +RE mapping: Refer to Subclauses 7.4.1.1.2 (PDSCH DM-RS), 7.4.1.3.2 (PDCCH DM-RS), 7.4.1.4.2 (PBCH DM-RS), 7.4.1.5.3 (CSI-RS/TRS), 7.4.1.2.2 (PT-RS), 7.4.2.2.2 (PSS) and 7.4.2.3.2 (SSS) in [6] for details. + +An O-DU AAL profile for 5G NR downlink shall specify a set of accelerated functions corresponding to one or more than one physical downlink channel(s) and/or physical downlink signal(s). + +In addition to the processing blocks mentioned above, each of these downlink physical channels/signals may include some additional functional blocks (e.g. precoding, IQ compression) which are implementation specific and may also depend on system configurations/capabilities (for example, whether a O-DU is connected to a CAT-A/CAT-B O-RU). Each of these physical channels/signals can be implemented with/without these optional functional blocks. The AAL Application interface shall expose to the AAL Application whether these functional blocks are supported or not within the AAL Implementation. + +Figure 7.1.1-2: illustrates the building blocks for processing various O-DU PHY layer Uplink (UL) channels and signals (with 7.2-x functional split between O-DU and O-RU) defined by 3GPP [6] as part of 5G NR specification. + +![Figure 7.1.1-2: O-DU PHY processing blocks for 5G NR Uplink. The diagram shows a block diagram of the O-DU PHY layer processing blocks for 5G NR Uplink. It is organized into columns for different channels: PUSCH UL data, PUCCH format 2/3/4 UCI, PUCCH format 1 UCI, PUCCH format 0 UCI, PRACH, SRS, and PT-RS. The blocks are arranged in a grid, with some blocks shared across channels. The top row is labeled 'L2+' and the bottom row is labeled 'O-RAN FH (7-2x lower layer split)'. The blocks include TB CRC check, CB CRC + CB Desegmentation, LDPC decoding, Rate dematching, CB Deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE demapping, IQ decompression*, CRC check, Polar/Block decoding, Rate dematching, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE demapping, IQ decompression*, Preamble detection + delay estimation, Peak search, Noise estimation, IFFT, Root sequence correlation, Channel estimation, RE demapping, IQ decompression*, Sequence detection, RE demapping, IQ decompression*, and RE demapping.](135d6702b4f82ef3da58c67c3401c7a6_img.jpg) + +| L2 + | | | | | | | +|-----------------------------------|--|-----------------------------------|--|---------------------------------------|--|--| +| <b>PUSCH<br/>UL data</b> | | <b>PUCCH format 2/3/4<br/>UCI</b> | | <b>PRACH</b> | | | +| TB CRC check | | CRC check | | Preamble detection + delay estimation | | | +| CB CRC + CB Desegmentation | | Polar/Block decoding | | Peak search | | | +| LDPC decoding | | Rate dematching | | Noise estimation | | | +| Rate dematching | | Descrambling | | IFFT | | | +| CB Deconcatenation | | Demodulation | | Root sequence correlation | | | +| Descrambling | | IDFT for DFT-s-OFDM | | Channel estimation | | | +| Demodulation | | Channel equalization | | RE demapping | | | +| IDFT for DFT-s-OFDM | | Channel estimation | | IQ decompression* | | | +| Channel equalization | | RE demapping | | IQ decompression* | | | +| Channel estimation | | IQ decompression* | | IQ decompression* | | | +| RE demapping | | IQ decompression* | | IQ decompression* | | | +| IQ decompression* | | IQ decompression* | | IQ decompression* | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | + +Figure 7.1.1-2: O-DU PHY processing blocks for 5G NR Uplink. The diagram shows a block diagram of the O-DU PHY layer processing blocks for 5G NR Uplink. It is organized into columns for different channels: PUSCH UL data, PUCCH format 2/3/4 UCI, PUCCH format 1 UCI, PUCCH format 0 UCI, PRACH, SRS, and PT-RS. The blocks are arranged in a grid, with some blocks shared across channels. The top row is labeled 'L2+' and the bottom row is labeled 'O-RAN FH (7-2x lower layer split)'. The blocks include TB CRC check, CB CRC + CB Desegmentation, LDPC decoding, Rate dematching, CB Deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE demapping, IQ decompression\*, CRC check, Polar/Block decoding, Rate dematching, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE demapping, IQ decompression\*, Preamble detection + delay estimation, Peak search, Noise estimation, IFFT, Root sequence correlation, Channel estimation, RE demapping, IQ decompression\*, Sequence detection, RE demapping, IQ decompression\*, and RE demapping. + +**Figure 7.1.1-2: O-DU PHY processing blocks for 5G NR Uplink** + +The O-DU PHY layer in uplink consists of the following physical channels and reference signals: + +- Physical Uplink Shared Channel (PUSCH). +- Physical Uplink Control Channels (PUCCH) with formats 0/1/2/3/4. +- Physical Random-Access Channel (PRACH). + +- Sounding Reference Signal (SRS). + - Phase Tracking Reference Signal (PT-RS) for UL. +- The uplink physical channels (PUSCH, PUCCH, PRACH) carry information originating from higher layers (i.e. layer 2 and above). +- The uplink physical layer processing of shared channel (PUSCH) carrying uplink data with or without Uplink Control Information (UCI) consists of the following steps at the receiver (O-DU): +- RE de-mapping: Refer to Subclauses 6.3.1.6, 6.3.1.7 and 6.4.1.1.3 of [6] for details on RE mapping at the transmitter. + - Channel estimation and equalization: up to O-DU implementation. + - Transform precoding (IDFT): optional, only required for DFT-s-OFDM waveform. Refer to Subclause 6.3.1.4 of [6] for details on transform precoding (if applicable) applied at the transmitter. + - Demodulation: Refer to Subclause 6.3.1.2 in [6] for details on modulation applied at the transmitter. + - Descrambling: Refer to Subclause 6.3.1.1 in [6] for details on scrambling applied at the transmitter. + - CB de-concatenation: Refer to Subclause 6.2.6 in [7] for details on CB concatenation applied at the transmitter. + - Rate de-matching: Refer to Subclause 6.2.5 in [7] for details on rate matching applied at the transmitter. + - LDPC decoding: Refer to Subclause 6.2.4 in [7] for details on LDPC encoding applied at the transmitter. + - CB de-segmentation and CB CRC check: Refer to Subclause 6.2.3 in [7] for details on CB segmentation and CB CRC attachment applied at the transmitter. + - TB CRC check: Refer to Subclause 6.2.1 in [7] for details on TB level CRC attachments applied at the transmitter. +- The uplink physical layer processing for control channel (PUCCH) carrying UCI depends on PUCCH formats. +- PUCCH format 0 processing consists of the following steps at the receiver (O-DU): +- RE de-mapping: Refer to subclause 6.3.2.3.2 of [6] for details on RE mapping applied at the transmitter. + - Sequence detection: The transmitted sequence (refer to Subclause 6.3.2.3 in [6] for details) is detected at O-DU using a non-coherent detector, since PUCCH format 0 does not carry any DM-RS. The detailed design is up to O-DU implementation. +- PUCCH format 1 processing consists of the following steps at the receiver (O-DU): +- RE de-mapping: Refer to Subclauses 6.3.2.4.2 and 6.4.1.3.1.2 of [6] for details on RE mapping applied at the transmitter. + - Channel estimation and equalization: up to O-DU implementation. + - Demodulation: Refer to Subclause 6.3.2.4.1 in [6] for details on modulation applied at the transmitter. +- PUCCH formats 2/3/4 processing consists of the following steps at the receiver (O-DU): +- RE de-mapping: Refer to Subclauses 6.3.2.5.3 and 6.4.1.3.2.2 (format 2); 6.3.2.6.5 and 6.4.1.3.3.2 (formats 3/4) of [6] for details on RE mapping applied at the transmitter. + - Channel estimation and equalization: up to O-DU implementation. + - Transform precoding (IDFT): optional, only required for DFT-s-OFDM waveform. Refer to Subclause 6.3.2.6.4 of [6] for details on transform precoding (applicable for formats 3/4) applied at the transmitter. + - Demodulation: Refer to Subclause 6.3.2.5.2 (format 2) and 6.3.2.6.2 (formats 3/4) in [6] for details on modulation applied at the transmitter. + - Descrambling: Refer to Subclause 6.3.2.5.1 (format 2) and 6.3.2.6.1 (formats 3/4) in [6] for details on scrambling applied at the transmitter. + +- 1 Rate de-matching: Refer to Subclause 6.3.1.4 in [7] for details on rate matching applied at the transmitter. +- 2 Polar/Block decoding: Refer to Subclause 6.3.1.3 in [7] for details on Polar/Block encoding applied at the transmitter. +- 3 CRC check: Refer to Subclause 6.3.1.2 in [7] for details on CRC attachment applied at the transmitter. +- 4 The uplink physical layer processing for random access channel (PRACH) carrying preamble consists of the following +- 5 steps at the receiver (O-DU): +- 6 RE de-mapping: Refer to Subclause 6.3.3.2 in [6] for details on RE mapping applied at the transmitter. +- 7 Root sequence correlation: Perform correlation operation between root sequence and received signals. Refer to +- 8 Subclause 6.3.3.1 in [6] for details on root sequence generation. +- 9 IFFT: perform the inverse Fast Fourier Transform (iFFT) operation on the received signal(s). +- 10 Noise estimation: perform the noise estimation operation. +- 11 Peak search: detect the peak for different root sequences. +- 12 Preamble detection and Timing Advance (TA) or delay estimation: determine the preamble sequence(s) received and +- 13 the corresponding timing advance estimate(s). +- 14 The uplink physical signals (SRS, PT-RS) do not carry any information from the higher layers (i.e. layer 2 and above). +- 15 The Sounding Reference Signal (SRS) in uplink is received at O-DU using the following steps: +- 16 RE de-mapping: Refer to Subclauses 6.4.1.4.3 and 6.4.1.4.4 in [6] for details on RE mapping applied at the transmitter. +- 17 Sequence detection and Channel estimation: Up to O-DU implementation. Refer to 6.4.1.4.2 in [6] for details on SRS +- 18 sequence generation at the transmitter. Channel condition in uplink is estimated at the O-DU based on the processing of +- 19 received SRS. +- 20 The Phase-Tracking Reference Signal (PT-RS) in uplink is received at the O-DU using the following steps: +- 21 RE de-mapping: Refer to Subclause 6.4.1.2.2 in [6] for details on RE mapping applied at the transmitter. +- 22 Sequence detection: Up to O-DU implementation. Refer to Subclause 6.4.1.2.1 in [6] for details on sequence generation +- 23 at the transmitter. +- 24 An O-DU AAL profile for 5G NR uplink shall specify a set of accelerated functions corresponding to one or more than +- 25 one physical uplink channel(s) and/or physical uplink signal(s). +- 26 In addition to the processing blocks mentioned above, each of these uplink physical channels/signals may include an +- 27 additional functional block, viz. IQ decompression, which is implementation specific and may depend on system +- 28 configuration/capability. Each of these physical channels/signals can be implemented with/without this optional +- 29 functional block. The AAL Application interface shall expose to the AAL Application whether these functional blocks +- 30 are supported or not within the AAL Implementation. + +###### 31 7.1.2 O-DU Protocol Stack Reference for mMTC + +32 Figure 7.1.2-1 illustrates the building blocks for processing various O-DU PHY layer Downlink (DL) channels and +33 signals (with 7.2-x functional split between O-DU and O-RU) defined by 3GPP in [8] & [9] as part of 4G/5G NR +34 specification. + +![](57eb1fd61c2ec867ba8077c797de3cfd_img.jpg) + +| L2+ | | | | | +|-----------------------------------|----------------------------------|----------------------------------|----------------------|---------------------| +| <b>NPDSCH TB(s)</b> | | <b>NPBCH TB</b> | | | +| TB CRC attachment | | PBCH payload generation | | | +| Tail Biting Convolutional Coding | | CRC attachment | | | +| | <b>N PDCCH (DCI)</b> | Tail Biting Convolutional Coding | | | +| Rate matching | CRC attachment | Rate Matching | | | +| CB concatenation | Tail Biting Convolutional Coding | Scrambling | <b>NPSS/NSSS/NRS</b> | <b>NPRS/NWUS</b> | +| Scrambling | Rate matching | Modulation | Sequence Generation | Sequence Generation | +| Modulation | Scrambling | Layer Mapping | Modulation | Modulation | +| Layer mapping | Modulation (QPSK) | | | | +| Precoding* | Precoding* | Precoding* | | Precoding* | +| RE mapping | RE mapping | RE mapping | | RE mapping | +| IQ compression* | IQ compression* | IQ compression* | | IQ compression* | +| O-RAN FH (7-2x lower layer split) | | | | | + +**Figure 7.1.2-1: O-DU PHY processing blocks for mMTC Downlink.** + +The O-DU PHY layer in downlink consists of the following physical channels and reference signals: + +- Narrow-band Physical Downlink Shared Channel (NPDSCH). +- Narrow-band Physical Downlink Control Channel (NPDCCH). +- Narrow-band Physical Broadcast Channel (NPBCH). +- Narrow-band Primary Synchronization Signal (NPSS). +- Narrow-band Secondary Synchronization Signal (NSSS). +- Narrow-band Reference Signal (NRS) and Narrow-band Position Reference Signal (NPRS). +- Narrow-band Wake-Up Signal (NWUS) + +The Narrow-band downlink physical channels (NPDSCH, NPDCCH, NPBCH) carry information originating from higher layers (i.e. layer 2 and above). + +The Narrow-band downlink physical layer processing of data channel (NPDSCH) carrying transport blocks consists of the following steps: + +TB CRC attachment: Error detection is provided on each transport block (TB) through a Cyclic Redundancy Check (CRC). Refer to Subclause 6.4 in [9] for details. + +CRC attachment: CRC attachment is performed according to Subclauses 6.4 of [9] + +- 1 Tail-biting Convolutional coding: Refer to Subclauses 6.2 and 5.1.3.1 in [9] for details. +- 2 Rate matching: Refer to Subclauses 6.4 in [9] for details. +- 3 Scrambling: Refer to Subclause 10.2.5.2 in [8] for details. +- 4 Modulation: Refer to Subclause 10.2.5.3 in [8] for details. +- 5 Layer mapping: Refer to Subclause 10.2.5.3 in [8] for details. +- 6 RE mapping: Refer to Subclause 10.2.5.5 in [8] for details on Resource Element (RE) mapping. +- 7 The downlink physical layer processing of control channel (PDCCH) carrying Downlink Control Information (DCI) +- 8 consists of the following steps: +- 9 CRC attachment: Error detection is provided on DCI transmissions through a Cyclic Redundancy Check (CRC). Refer +- 10 to Subclause 6.4 in [9] for details. +- 11 Tail-biting Convolutional coding: Refer to Subclauses 6.2 and 5.1.3.1 in [9] for details. +- 12 Scrambling: Refer to Subclause 10.2.5.2 in [8] for details. +- 13 Modulation: Refer to Subclause 10.2.5.3 in [8] for details. +- 14 Layer mapping: Refer to Subclause 10.2.5.3 in [8] for details. +- 15 RE mapping: Refer to Subclause 10.2.5.5 in [8] for details on Resource Element (RE) mapping. +- 16 The downlink physical layer processing of broadcast channel (NPBCH) carrying maximum one transport block consists +- 17 of the following steps: +- 18 NPBCH payload generation: Refer to Subclause 6.4.1 in [9] for details. +- 19 TB CRC attachment: Error detection is provided on each transport block (TB) through a Cyclic Redundancy Check +- 20 (CRC). Refer to Subclause 6.4 in [9] for details. +- 21 Scrambling: Refer to Subclause 10.2.5.2 in [8] for details. +- 22 Modulation: Refer to Subclause 10.2.5.3 in [8] for details. +- 23 Layer mapping: Refer to Subclause 10.2.5.3 in [8] for details. +- 24 RE mapping: Refer to Subclause 10.2.5.5 in [8] for details on Resource Element (RE) mapping. +- 25 The downlink physical signals (NRS, NPSS, NSSS, NPRS, NWUS) correspond to a set of resource elements used by +- 26 the physical layer but does not carry information originated from higher layers (i.e., layer 2 and above). +- 27 Reference Signals and Synchronization signals (NPSS/NSSS) are generated using the following steps: +- 28 Sequence Generation and Modulation and RE mapping: Refer to Subclauses, 10.2.6B (NWUS), 10.2.7.1 (NPSS) and +- 29 10.2.7.2 (NSSS), 10.2.6 (NRS), 10.2.6A (NPRS) in [8] for details. +- 30 An O-DU AAL profile for 4G NR downlink shall specify a set of accelerated functions corresponding to one or more +- 31 than one physical downlink channel(s) and/or physical downlink signal(s). +- 32 In addition to the processing blocks mentioned above, each of these downlink physical channels/signals may include +- 33 some additional functional blocks (e.g., precoding, IQ compression) which are implementation specific and may also +- 34 depend on system configurations/capabilities (for example, whether a O-DU is connected to a CAT-A/CAT-B O-RU). +- 35 Each of these physical channels/signals can be implemented with/without these optional functional blocks. The AAL +- 36 Application interface shall expose to the AAL Application whether these functional blocks are supported or not within +- 37 the AAL Implementation. +- 38 Figure 7.1.2-2 illustrates the building blocks for processing various O-DU PHY layer Uplink (UL) channels and signals +- 39 (with 7.2-x functional split between O-DU and O-RU) defined by 3GPP in [8] & [9] as part of 4G/5G NR specification. + +Image: O-RAN Alliance Logo + +O-RAN.WG6.AAL-GaNP-R0004-v11.00 +![](1a0bfaeada675879df21fedb1adc863d_img.jpg) + +**L2 +** + +**Figure 7.1.2-2: O-DU PHY processing blocks for mMTC Uplink** + +This diagram shows the processing blocks for mMTC Uplink in O-DU PHY, split into four main processing paths from left to right, all originating from the O-RAN FH (7-2x lower layer split) at the bottom and leading to L2+ at the top: + +- NPUSCH UL data:** IQ decompression\* → RE demapping → Channel estimation → Channel equalization → IDFT for DFT-s-OFDM → Layer Demapping → Demodulation → Descrambling → Rate dematching → Turbo decoding → CRC check. +- DMRS with PUSCH Format 1 and Format 2:** IQ decompression\* → RE demapping → Channel Estimation. +- PUSCH Format 2 UCI:** IQ decompression\* → RE demapping → Channel estimation → Channel equalization → Demodulation → Descrambling → Rate dematching → Channel decoding → AC-NACK detection. +- NPRACH:** IQ decompression\* → RE demapping → Root sequence correlation → IFFT → Noise estimation → Peak search → Preamble detection + delay estimation. + +*Note: \* IQ decompression is optional/implementation dependent.* + +The O-DU PHY layer in uplink consists of the following physical channels and reference signals: + +- Narrow-band Physical Uplink Shared Channel (NPUSCH). +- Narrow-band Physical Random-Access Channel (NPRACH). + +The uplink physical channels (NPUSCH, NPRACH) carry information originating from higher layers (i.e., layer 2 and above). + +The uplink physical layer processing of shared channel (NPUSCH) carrying uplink data with or without Uplink Control Information (UCI) consists of the following steps at the receiver (O-DU): + +RE (de)mapping: Refer to Subclauses 5.3.4 of [8] for details on RE mapping at the transmitter/receiver. + +Channel estimation and equalization: up to O-DU implementation. + +Transform precoding (IDFT): optional, only required for DFT-s-OFDM waveform. Refer to Subclause 5.3.3A of [8] for details on transform precoding (if applicable) applied at the transmitter. + +Demodulation: Refer to Subclause 5.3.2 in [8] for details on modulation applied at the transmitter. + +Descrambling: Refer to Subclause 5.3.1 in [8] for details on scrambling applied at the transmitter. + +Rate de-matching: Refer to Subclause 5.1.4.1 in [9] for details on rate matching applied at the transmitter. + +--- + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. +46 + +Turbo decoding: Refer to Subclause 5.1.3.2 in [9] for details on Turbo decoding applied at the transmitter. + +CRC check: Refer to Subclauses 5.1.1 in [9] for details on TB and CB level CRC attachments applied at the transmitter. + +The uplink physical layer processing for shared channel (NPUSCH) carrying UCI depends on NPUSCH formats. + +An O-DU AAL profile for 4G/5G NR uplink shall specify a set of accelerated functions corresponding to one or more than one physical uplink channel(s) and/or physical uplink signal(s). + +In addition to the processing blocks mentioned above, each of these uplink physical channels/signals may include an additional functional block, viz. IQ decompression, which is implementation specific and may depend on system configuration/capability. Each of these physical channels/signals can be implemented with/without this optional functional block. The AAL Application interface shall expose to the AAL Application whether these functional blocks are supported or not within the AAL Implementation. + +### 7.1.3 O-DU AAL Profile Definitions + +O-DU AAL profiles are defined below with future specification(s) to define the AAL Application interface for each profile. + +#### 7.1.3.1 Profile Definitions General Guidelines + +##### 7.1.3.1.1 Naming + +As discussed above O-DU AAL profiles are specific to one or more physical channel(s) or signal(s) as such should follow the naming guidelines + +- O-DU AAL profiles shall be prefixed with “AAL\_” +- O-DU AAL profiles when specific to a single channel or signal shall include the channel or signal in the name e.g. “AAL\_PUSCH” +- O-DU AAL profiles when common across multiple channels or signals shall not include the channel or signal name, instead just reference the Accelerated Function(s), e.g. AAL\_RE-MAPPING +- O-DU AAL profiles that include a subset of the functional blocks within a channel or signal shall include a functional description after the channel name e.g. AAL\_PUSCH\_CHANNEL\_ESTIMATION + +##### 7.1.3.1.2 Data Flow + +O-DU AAL profiles shall specify the data flow supported by the AAL Profile. + +Look aside data flow implies the remaining functions not included in the Profile that comprise the channel or signal are implemented on the AAL Application or other entity associated with the AAL Application and not implemented in the HW Accelerator. + +Inline data flow implies that the signal (with a 7-2x PHY functional split) and the IQ data from the AAL Application (in DL) or the decoded bits (in UL) (post processing) are transferred directly from the HW Accelerator to the Fronthaul interface (in DL) or to the AAL Application (in UL). + +The profile shall specify if the data flow includes only user plane, or only control plane, or both. + +###### 1 7.1.3.2 O-DU AAL Profiles + +###### 2 7.1.3.2.1 AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC + +![Figure 7.1.3.2.1-1: AAL_MU-MIMO_PRECODER_WEIGHTS_CALC. A vertical stack of four boxes representing L2 and L1 layers. The top three boxes are grouped under L2, and the bottom box is under L1.](2a69f8d527e2dec67be51d8e5e0db717_img.jpg) + +Figure 7.1.3.2.1-1 shows a vertical stack of four functional blocks. The top three blocks are grouped under the L2 layer, and the bottom block is under the L1 layer. The blocks are: + +- User Grouping and Scheduling** (L2) +- Precoder/BF Weights Calculation** (L2) +- Link Adaptation, MCS selection** (L2) +- TB Formation and associated control information** (L2) +- High Phy** (L1) + +Figure 7.1.3.2.1-1: AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC. A vertical stack of four boxes representing L2 and L1 layers. The top three boxes are grouped under L2, and the bottom box is under L1. + +4 **Figure 7.1.3.2.1-1: AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC** + +5 The AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC is used by AAL Application to offload beamforming +6 (precoding) weight calculation to the hardware accelerator (HWA) in look-aside acceleration mode. The AAL +7 Application shall provide HWA with all the information required to calculate precoding weights. + +8 This profile is implemented as a look aside accelerator. + +9 The below figure shows an example use of the AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC in an O-DU with +10 AAL\_DOWNLINK\_HIGH-PHY and AAL\_UPLINK\_HIGH-PHY + +![Figure 7.1.3.2.1-2: Example AAL_MU-MIMO_PRECODER_WEIGHTS_CALC use. A diagram showing the interaction between the AAL Application and the HW Accelerator.](d3ac347210ad889d4e7296db2f602c59_img.jpg) + +Figure 7.1.3.2.1-2 illustrates the interaction between the AAL Application and the HW Accelerator. The AAL Application is located in the GPP/CPU layer, while the HW Accelerator is in the hardware layer. The AAL Application contains two main components: Precoder/BF Weights Calculation Function and High PHY Profile. The HW Accelerator also contains these two components. The diagram shows the following data flow: + +- Look-aside AAL Profile for precoder calculation:** A red arrow points from the Precoder/BF Weights Calculation Function in the HW Accelerator to the Precoder/BF Weights Calculation Function in the AAL Application. +- Inline High Phy AAL Profile for slot level data path procedure:** A red arrow points from the High PHY Profile in the HW Accelerator to the High PHY Profile in the AAL Application. +- Data Path:** A black arrow points from the AAL Application down to the HW Accelerator, and another black arrow points from the HW Accelerator up to the AAL Application. + +Figure 7.1.3.2.1-2: Example AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC use. A diagram showing the interaction between the AAL Application and the HW Accelerator. + +11 **Figure 7.1.3.2.1-2: Example AAL\_MU-MIMO\_PRECODER\_WEIGHTS\_CALC use.** + +##### 7.1.3.2.2 AAL\_FFT + +![Figure 7.1.3.2.2-1: AAL_FFT block diagram showing processing flows for PUSCH, PUCCH, PRACH, SRS, and PT-RS. The diagram is organized into columns for each channel type. PUSCH UL data includes TB CRC check, CB CRC + CB desegmentation, LDPC decoding, Rate dematching, CB deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM (highlighted), Channel equalization, Channel estimation, RE demapping, and IQ decompression*. PUCCH format 2/3/4 UCI includes CRC check, Polar/Block decoding, Rate dematching, Descrambling, Demodulation, IDFT for DFT-s-OFDM (highlighted), Channel equalization, Channel estimation, RE demapping, and IQ decompression*. PUCCH format 1 UCI includes Demodulation, Channel equalization, Channel estimation, RE demapping, and IQ decompression*. PUCCH format 0 UCI includes Sequence detection, RE demapping, and IQ decompression*. PRACH includes Preamble detection + delay estimation, Peak search, Noise estimation, IFFT (highlighted), Root sequence correlation, RE demapping, and IQ decompression*. SRS includes Channel estimation (highlighted), RE demapping, and IQ decompression*. PT-RS includes Sequence detection, RE demapping, and IQ decompression*. The entire diagram is labeled 'O-RAN FH (7-2x lower layer split)'.](6483ff7c5003c9b7a0ed8bcc98e902db_img.jpg) + +Figure 7.1.3.2.2-1: AAL\_FFT block diagram showing processing flows for PUSCH, PUCCH, PRACH, SRS, and PT-RS. The diagram is organized into columns for each channel type. PUSCH UL data includes TB CRC check, CB CRC + CB desegmentation, LDPC decoding, Rate dematching, CB deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM (highlighted), Channel equalization, Channel estimation, RE demapping, and IQ decompression\*. PUCCH format 2/3/4 UCI includes CRC check, Polar/Block decoding, Rate dematching, Descrambling, Demodulation, IDFT for DFT-s-OFDM (highlighted), Channel equalization, Channel estimation, RE demapping, and IQ decompression\*. PUCCH format 1 UCI includes Demodulation, Channel equalization, Channel estimation, RE demapping, and IQ decompression\*. PUCCH format 0 UCI includes Sequence detection, RE demapping, and IQ decompression\*. PRACH includes Preamble detection + delay estimation, Peak search, Noise estimation, IFFT (highlighted), Root sequence correlation, RE demapping, and IQ decompression\*. SRS includes Channel estimation (highlighted), RE demapping, and IQ decompression\*. PT-RS includes Sequence detection, RE demapping, and IQ decompression\*. The entire diagram is labeled 'O-RAN FH (7-2x lower layer split)'. + +**Figure 7.1.3.2.2-1: AAL\_FFT** + +The AAL\_FFT is used by application to offload FFT/iFFT processing to the hardware accelerator (HWA) in look-aside acceleration mode. The application shall provide HW Accelerator with all the information required to perform the FFT operations. The AAL\_FFT Profile can be used for 3GPP specification 38.211 clause 5.3, and clause 6.4.1.4. The below list and Figure 7.1.3.2.2-1: AAL\_FFT highlights the set of accelerated functions that define the AAL\_FFT Profile. + +- Zero Padding +- iDFT +- Windowing +- DFT +- De padding +- Timing Error Correction +- Frequency De-Windowing +- Frequency Re-Sampling + +The below figure shows an example use of the AAL\_FFT Profile for accelerating the SRS processing in an O-DU. The highlighted blocks show the set the accelerated functions while the clear blocks are implemented in software. + +![Block diagram of AAL_FFT example for SRS Processing. The main processing chain consists of: Zadoff-Chu, RB/Comb Extraction (white box), Zero Padding (yellow box), iDFT (yellow box), Ncs Windowing (yellow box), Ncs DFT (yellow box), Depadding (yellow box), Time Error Correction* (dashed yellow box), De-windowing* (dashed yellow box), and Freq re-sample* (dashed yellow box). A side path from Depadding leads to FFT Power* (dashed yellow box). Below this is SNR and Channel Estimate. (white box). The output of the main chain goes to SRS Channel estimation (yellow box), which then branches to RE demapping (white box), IQ decompression* (dashed white box), and O-RAN FH (7-2x lower layer split) (white box). A separate L2+ (white box) is also shown.](c0ac65c22121c83581896fac19443988_img.jpg) + +``` + +graph TD + A[Zadoff-Chu, RB/Comb Extraction] --> B[Zero Padding] + B --> C[iDFT] + C --> D[Ncs Windowing] + D --> E[Ncs DFT] + E --> F[Depadding] + F --> G[Time Error Correction*] + G --> H[De-windowing*] + H --> I[Freq re-sample*] + F --> J[FFT Power*] + J --> K[SNR and Channel Estimate.] + I --> L[SRS Channel estimation] + L --> M[RE demapping] + M --> N[IQ decompression*] + N --> O[O-RAN FH 7-2x lower layer split] + P[L2+] + +``` + +Block diagram of AAL\_FFT example for SRS Processing. The main processing chain consists of: Zadoff-Chu, RB/Comb Extraction (white box), Zero Padding (yellow box), iDFT (yellow box), Ncs Windowing (yellow box), Ncs DFT (yellow box), Depadding (yellow box), Time Error Correction\* (dashed yellow box), De-windowing\* (dashed yellow box), and Freq re-sample\* (dashed yellow box). A side path from Depadding leads to FFT Power\* (dashed yellow box). Below this is SNR and Channel Estimate. (white box). The output of the main chain goes to SRS Channel estimation (yellow box), which then branches to RE demapping (white box), IQ decompression\* (dashed white box), and O-RAN FH (7-2x lower layer split) (white box). A separate L2+ (white box) is also shown. + +Note The figure represents the two data outputs from the profile, the FFT Power estimate and the frequency samples. + +Note The figure is a representative example implementation of SRS Channel estimation only + +**Figure 7.1.3.2.2-2: AAL\_FFT example for SRS Processing** + +This profile is implemented as a look aside accelerator. + +#### 7.1.3.3 O-DU AAL Profiles for Downlink + +##### 7.1.3.3.1 AAL\_PDSCH\_FEC + +Figure 7.1.3.3.1-1 highlights the set of accelerated functions that define the AAL\_PDSCH\_FEC Profile. These include: + +- CRC Generation +- LDPC Encoding +- PDSCH Rate Matching + +The AAL\_PDSCH\_FEC Profile is implemented as a look aside accelerator. The AAL\_PDSCH\_FEC Profile will support both Transport Block and Code Block operations. + +![Figure 7.1.3.3.1-1: AAL_PDSCH_FEC Profile block diagram showing the processing flow for PDSCH TB(s), PDCCH (DCI), PBCH TB, and associated DM-RS and RS/PT-RS/TRS.](99e5cd41877d35e56d036042dac4cca5_img.jpg) + +The diagram illustrates the AAL\_PDSCH\_FEC Profile processing flow, organized into four main columns: PDSCH TB(s), PDCCH (DCI), PBCH TB, and associated DM-RS/RS/PT-RS/TRS. The flow is as follows: + +- PDSCH TB(s) Column:** + - Top section (yellow boxes): TB CRC attachment, CB segmentation + CB CRC attachment, LDPC encoding, Rate matching. + - Middle section: CB concatenation, Scrambling, Modulation, Layer mapping. + - Bottom section (dashed boxes): Precoding\*, RE mapping, IQ compression\*. +- PDCCH (DCI) Column:** + - Top section: CRC attachment, Polar encoding, Rate matching. + - Middle section: Scrambling, Modulation (QPSK). + - Bottom section (dashed boxes): Precoding\*, RE mapping, IQ compression\*. +- PBCH TB Column:** + - Top section: PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching. + - Middle section: Data scrambling, Modulation (QPSK). + - Bottom section (dashed boxes): Precoding\*, RE mapping, IQ compression\*. +- Associated DM-RS/RS/PT-RS/TRS Columns:** + - PDSCH DM-RS:** Sequence generation, Modulation. + - PDCCH DM-RS:** Sequence generation, Modulation. + - PSS/SSS PBCH DM-RS:** Sequence Generation, Modulation. + - CSI-RS/PT-RS/TRS:** Sequence Generation, Modulation. + +The entire flow is contained within a large box labeled "O-RAN FH (7-2x lower layer split)". + +Figure 7.1.3.3.1-1: AAL\_PDSCH\_FEC Profile block diagram showing the processing flow for PDSCH TB(s), PDCCH (DCI), PBCH TB, and associated DM-RS and RS/PT-RS/TRS. + +**Figure 7.1.3.3.1-1: AAL\_PDSCH\_FEC Profile** + +##### 7.1.3.3.2 AAL\_PDSCH\_HIGH-PHY + +Figure 7.1.3.3.2-1 highlights the set of accelerated functions that defines the AAL\_PDSCH\_HIGH-PHY Profile, which includes the processing of PDSCH TB(s) and associated DM-RS. + +The set of accelerated functions associated with the processing of PDSCH TB(s) is as follows: + +- TB CRC attachment +- CB segmentation and CRC attachment +- LDPC encoding +- Rate matching +- CB concatenation +- Scrambling +- Modulation +- Layer mapping +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +<sup>1</sup> Configurable functional block, depends on implementation and/or system configuration + +The set of accelerated functions associated with the processing of PDSCH DM-RS is as follows: + +- PDSCH DM-RS sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The AAL\_PDSCH\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.3.2-1: AAL_PDSCH_HIGH-PHY Profile block diagram showing the flow of data through various processing blocks for PDSCH, PDCCH, PBCH, and CSI-RS/PT-RS/TRS.](2368c7b690b2d16a027385323a0c4645_img.jpg) + +The diagram illustrates the AAL\_PDSCH\_HIGH-PHY Profile architecture, showing the flow of data through various processing blocks. The architecture is organized into several main sections: + +- L2+ (Top Layer):** A horizontal bar at the top representing the L2+ layer. +- PDSCH TB(s) Processing:** + - TB CRC attachment + - CB segmentation + CRC attachment + - LDPC encoding + - Rate matching + - CB concatenation + - Scrambling + - Modulation + - Layer mapping + - Precoding\* (dashed box) + - RE mapping + - IQ compression\* (dashed box) +- PDCCH (DCI) Processing:** + - CRC attachment + - Polar encoding + - Rate matching + - Scrambling + - Modulation (QPSK) + - Precoding\* (dashed box) + - RE mapping + - IQ compression\* (dashed box) +- PBCH TB Processing:** + - PBCH payload generation + - Scrambling + - TB CRC attachment + - Polar encoding + - Rate matching + - Data scrambling + - Modulation (QPSK) + - Precoding\* (dashed box) + - RE mapping + - IQ compression\* (dashed box) +- DM-RS and Reference Signal Processing:** + - PDSCH DM-RS:** Sequence generation, Modulation + - PDCCH DM-RS:** Sequence generation, Modulation + - PSS/SSS PBCH DM-RS:** Sequence Generation, Modulation + - CSI-RS/PT-RS/TRS:** Sequence Generation, Modulation +- O-RAN FH (7-2x lower layer split):** A horizontal bar at the bottom representing the O-RAN FH layer. + +Figure 7.1.3.3.2-1: AAL\_PDSCH\_HIGH-PHY Profile block diagram showing the flow of data through various processing blocks for PDSCH, PDCCH, PBCH, and CSI-RS/PT-RS/TRS. + +Figure 7.1.3.3.2-1: AAL\_PDSCH\_HIGH-PHY Profile + +##### 7.1.3.3.3 AAL\_PDCCH\_HIGH-PHY + +Figure 7.1.3.3.3-1 highlights the set of accelerated functions that defines the AAL\_PDCCH\_HIGH-PHY Profile, which includes the processing of PDCCH DCI and associated DM-RS. + +The set of accelerated functions associated with the processing of PDCCH TB(s) is as follows: + +- CRC attachment +- Polar encoding +- Rate matching +- Scrambling +- Modulation (QPSK) + +- Precoding<sup>1</sup> + - RE mapping + - IQ compression<sup>1</sup> +- The set of accelerated functions associated with the processing of PDCCH DM-RS is as follows: +- PDCCH DM-RS sequence generation + - Modulation + - Precoding<sup>1</sup> + - RE mapping + - IQ compression<sup>1</sup> +- The AAL\_PDCCH\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.3.3-1: AAL_PDCCH_HIGH-PHY Profile. This block diagram illustrates the processing flow for the AAL_PDCCH_HIGH-PHY Profile. It is divided into three main sections: PDSCH TB(s), PDCCH (DCI), and PBCH TB. The PDSCH TB(s) section includes TB CRC attachment, CB segmentation + CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. The PDCCH (DCI) section includes CRC attachment, Polar encoding, Rate matching, Scrambling, and Modulation (QPSK). The PBCH TB section includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, Modulation (QPSK), and Sequence Generation. The diagram also shows the associated DM-RS, PSS/SSS, and CSI-RS/PT-RS/TRS processing. The PDSCH DM-RS section includes Sequence generation and Modulation. The PBCH DM-RS section includes Sequence Generation and Modulation. The CSI-RS/PT-RS/TRS section includes Sequence Generation and Modulation.](7c4b14b9a068a7634206a06b2ce30490_img.jpg) + +Figure 7.1.3.3.3-1: AAL\_PDCCH\_HIGH-PHY Profile. This block diagram illustrates the processing flow for the AAL\_PDCCH\_HIGH-PHY Profile. It is divided into three main sections: PDSCH TB(s), PDCCH (DCI), and PBCH TB. The PDSCH TB(s) section includes TB CRC attachment, CB segmentation + CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. The PDCCH (DCI) section includes CRC attachment, Polar encoding, Rate matching, Scrambling, and Modulation (QPSK). The PBCH TB section includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, Modulation (QPSK), and Sequence Generation. The diagram also shows the associated DM-RS, PSS/SSS, and CSI-RS/PT-RS/TRS processing. The PDSCH DM-RS section includes Sequence generation and Modulation. The PBCH DM-RS section includes Sequence Generation and Modulation. The CSI-RS/PT-RS/TRS section includes Sequence Generation and Modulation. + +Figure 7.1.3.3.3-1: AAL\_PDCCH\_HIGH-PHY Profile + +##### 7.1.3.3.4 AAL\_PBCH\_HIGH-PHY + +Figure 7.1.3.3.4-1 highlights the set of accelerated functions that defines the AAL\_PBCH\_HIGH-PHY Profile, which includes the processing of PBCH TB and associated DM-RS, PSS and SSS, or in other words, the processing of SSB. + +- The set of accelerated functions associated with the processing of PBCH TB is as follows: +- PBCH payload generation + - Scrambling + - TB CRC attachment + - Polar encoding + +- Rate matching +- Data scrambling +- Modulation (QPSK) +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The set of accelerated functions associated with the processing of PBCH DM-RS/PSS/SSS is as follows: + +- PDCCH DM-RS/PSS/SSS sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The AAL\_PBCH\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Block diagram of the AAL_PBCH_HIGH-PHY Profile showing processing flows for PDSCH, PDCCH, PBCH, and CSI-RS/PT-RS/TRS.](6565f31e5207edefc397e4c337893a93_img.jpg) + +The diagram illustrates the AAL\_PBCH\_HIGH-PHY Profile architecture, showing the flow of data through various processing blocks. The architecture is organized into several main sections: PDSCH TB(s), PDCCH (DCI), PBCH TB, PSS/SSS, and CSI-RS/PT-RS/TRS. The PDSCH TB(s) section includes TB CRC attachment, CB segmentation + CB CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. The PDCCH (DCI) section includes CRC attachment, Polar encoding, Rate matching, Scrambling, Modulation (QPSK), and Modulation. The PBCH TB section includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, Modulation (QPSK), and Modulation. The PSS/SSS section includes Sequence Generation and Modulation. The CSI-RS/PT-RS/TRS section includes Sequence Generation and Modulation. The diagram also shows Precoding\* and RE mapping blocks for each of the main sections. The entire architecture is supported by O-RAN FH (7-2x lower layer split). + +Block diagram of the AAL\_PBCH\_HIGH-PHY Profile showing processing flows for PDSCH, PDCCH, PBCH, and CSI-RS/PT-RS/TRS. + +**Figure 7.1.3.3.4-1: AAL\_PBCH\_HIGH-PHY Profile** + +##### 7.1.3.3.5 AAL\_CSI-RS\_HIGH-PHY + +Figure 7.1.3.3.5-1 highlights the set of accelerated functions that defines the AAL\_CSI-RS\_HIGH-PHY Profile, which includes the following: + +- CSI-RS sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The AAL\_CSI-RS\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.3.5-1: AAL_CSI-RS_HIGH-PHY Profile block diagram showing the flow from L2+ through various processing blocks for PDSCH, PBCH, and PDCCH, including DM-RS and CSI-RS/PT-RS/TRS paths.](dd29fae82ae7f2977dc147f776f500da_img.jpg) + +The diagram illustrates the AAL\_CSI-RS\_HIGH-PHY Profile architecture. It is organized into several main sections: PDSCH TB(s), PBCH TB, PDCCH (DCI), and CSI-RS/PT-RS/TRS. The PDSCH TB(s) section includes TB CRC attachment, CB segmentation + CB CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. The PBCH TB section includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, and Modulation (QPSK). The PDCCH (DCI) section includes CRC attachment, Polar encoding, Rate matching, Scrambling, and Modulation (QPSK). The CSI-RS/PT-RS/TRS section includes Sequence Generation, Modulation, Precoding\*, RE Mapping, and IQ compression\*. The diagram also shows the flow of DM-RS (PDSCH DM-RS, PDCCH DM-RS, PSS/SSS PBCH DM-RS) and the overall processing flow from L2+ through the O-RAN FH (7-2x lower layer split). + +Figure 7.1.3.3.5-1: AAL\_CSI-RS\_HIGH-PHY Profile block diagram showing the flow from L2+ through various processing blocks for PDSCH, PBCH, and PDCCH, including DM-RS and CSI-RS/PT-RS/TRS paths. + +**Figure 7.1.3.3.5-1: AAL\_CSI-RS\_HIGH-PHY Profile** + +##### 7.1.3.3.6 AAL\_PT-RS-DL\_HIGH-PHY + +Figure 7.1.3.3.6-1 highlights the set of accelerated functions that defines the AAL\_PT-RS-DL\_HIGH-PHY Profile, which includes the following: + +- PT-RS sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The AAL\_PT-RS-DL\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.3.6-1: AAL_PT-RS-DL_HIGH-PHY Profile. This block diagram illustrates the processing flow for the AAL_PT-RS-DL_HIGH-PHY profile. It is organized into columns representing different data streams: PDSCH TB(s), PDCCH (DCI), PBCH TB, PDSCH DM-RS, PDCCH DM-RS, PSS/SSS PBCH DM-RS, and PT-RS-DL. The PDSCH TB(s) column includes TB CRC attachment, CB segmentation + CB CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. The PDCCH (DCI) column includes CRC attachment, Polar encoding, Rate matching, Scrambling, and Modulation (QPSK). The PBCH TB column includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, and Modulation (QPSK). The PDSCH DM-RS column includes Sequence generation and Modulation. The PDCCH DM-RS column includes Sequence generation and Modulation. The PSS/SSS PBCH DM-RS column includes Sequence Generation and Modulation. The PT-RS-DL column includes Sequence Generation, Modulation, Precoding*, RE Mapping, and IQ compression*. The diagram also shows Precoding*, RE mapping, and IQ compression* blocks for the PDSCH TB(s), PDCCH (DCI), and PBCH TB streams. The entire processing flow is contained within an O-RAN FH (7-2x lower layer split) block.](1cb29b8fd8e4a828f60ce6313a2eacdd_img.jpg) + +Figure 7.1.3.3.6-1: AAL\_PT-RS-DL\_HIGH-PHY Profile. This block diagram illustrates the processing flow for the AAL\_PT-RS-DL\_HIGH-PHY profile. It is organized into columns representing different data streams: PDSCH TB(s), PDCCH (DCI), PBCH TB, PDSCH DM-RS, PDCCH DM-RS, PSS/SSS PBCH DM-RS, and PT-RS-DL. The PDSCH TB(s) column includes TB CRC attachment, CB segmentation + CB CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, and Layer mapping. The PDCCH (DCI) column includes CRC attachment, Polar encoding, Rate matching, Scrambling, and Modulation (QPSK). The PBCH TB column includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, and Modulation (QPSK). The PDSCH DM-RS column includes Sequence generation and Modulation. The PDCCH DM-RS column includes Sequence generation and Modulation. The PSS/SSS PBCH DM-RS column includes Sequence Generation and Modulation. The PT-RS-DL column includes Sequence Generation, Modulation, Precoding\*, RE Mapping, and IQ compression\*. The diagram also shows Precoding\*, RE mapping, and IQ compression\* blocks for the PDSCH TB(s), PDCCH (DCI), and PBCH TB streams. The entire processing flow is contained within an O-RAN FH (7-2x lower layer split) block. + +Figure 7.1.3.3.6-1: AAL\_PT-RS-DL\_HIGH-PHY Profile + +##### 7.1.3.3.7 AAL\_DOWNLINK\_HIGH-PHY + +Figure 7.1.3.3.7-1 highlights the set of accelerated functions that defines the AAL\_DOWNLINK\_HIGH-PHY Profile. This profile includes the aggregation of all the individual downlink channel profiles as follows: + +###### PDSCH + +- **Data:** see list of accelerated functions associated with the processing of PDSCH TB(s), per section 7.1.3.3.2 +- **DM-RS:** see list of accelerated functions associated with the processing of PDSCH DM-RS, per section 7.1.3.3.2. +- **PT-RS:** see list of accelerated functions listed in section 7.1.3.3.6. + +###### PDCCH: + +- **Data:** see list of accelerated functions associated with the processing of PDCCH TB(s), per section 7.1.3.3.3 +- **DM-RS:** see list of accelerated functions associated with the processing of PDCCH DM-RS, per section 7.1.3.3.3 + +###### SSB: + +- **PSS + SSS:** see list of accelerated functions associated with the processing of PSS/SSS, per section 7.1.3.3.4 +- **PBCH DM-RS:** see list of accelerated functions associated with the processing of PBCH DM-RS, per section 7.1.3.3.4 +- **PBCH:** see list of accelerated functions associated with the processing of PBCH TB(s), per section 7.1.3.3.4 + +###### CSI-RS: + +- see list of accelerated functions listed in section 7.1.3.3.5 + +The AAL\_DOWNLINK\_HIGH-PHY Profile is executed in inline acceleration mode. + +![](eea56fc90b16d8b6fbf7a2a3cb30b69f_img.jpg) + +| L2+ | | | | | | | | +|-----------------------------------|--|---------------------|-------------------|-------------------------|---------------------|-------------------|-------------------------| +| <b>PDSCH TB(s)</b> | | | | <b>PBCH TB</b> | | | | +| TB CRC attachment | | | | PBCH payload generation | | | | +| CB segmentation + CRC attachment | | | | Scrambling | | | | +| LDPC encoding | | <b>PDCCH (DCI)</b> | | TB CRC attachment | | | | +| Rate matching | | CRC attachment | | Polar encoding | | | | +| CB concatenation | | Polar encoding | | Rate matching | | <b>PSS/SSS</b> | | +| Scrambling | | <b>PDSCH DM-RS</b> | Rate matching | <b>PDCCH DM-RS</b> | Data scrambling | <b>PBCH DM-RS</b> | <b>CSI-RS/PT-RS/TRS</b> | +| Modulation | | Sequence generation | Scrambling | Sequence generation | Sequence Generation | | | +| Layer mapping | | Modulation | Modulation (QPSK) | Modulation | Modulation (QPSK) | Modulation | Modulation | +| Precoding* | | Precoding* | | Precoding* | | Precoding* | | +| RE mapping | | RE mapping | | RE mapping | | RE Mapping | | +| IQ compression* | | IQ compression* | | IQ compression* | | IQ compression* | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +Figure 7.1.3.3.7-1AAL\_DOWNLINK\_HIGH-PHY Profile + +#### 7.1.3.4 O-DU AAL Profiles for Uplink + +##### 7.1.3.4.1 AAL\_PUSCH\_FEC + +Figure 7.1.3.4.1-1 highlights the set of accelerated functions that define the AAL\_PUSCH\_FEC Profile. These include: + +- PUSCH Rate De-matching +- LDPC Decoder +- CRC Check + +The AAL\_PUSCH\_FEC Profile is implemented as a look aside accelerator. The AAL\_PUSCH\_FEC Profile will support both Transport Block and Code Block operations. + +![](f89a396ed972d10263aa24c104c62c58_img.jpg) + +| L2 + | | | | | | | | +|---------------------------------------|--|--|--|--|--|--|--| +| <b>PUSCH</b> | | | | | | | | +| UL data | | | | | | | | +| TB CRC check | | | | | | | | +| CB CRC + CB desegmentation | | | | | | | | +| LDPC decoding | | | | | | | | +| Rate dematching | | | | | | | | +| CB deconcatenation | | | | | | | | +| Descrambling | | | | | | | | +| Demodulation | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PUCCH format 0 UCI</b> | | | | | | | | +| Sequence detection | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PUCCH format 1 UCI</b> | | | | | | | | +| Demodulation | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PUCCH format 2/3/4 UCI</b> | | | | | | | | +| CRC check | | | | | | | | +| Polar/Block decoding | | | | | | | | +| Rate dematching | | | | | | | | +| Descrambling | | | | | | | | +| Demodulation | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PRACH</b> | | | | | | | | +| Preamble detection + delay estimation | | | | | | | | +| Peak search | | | | | | | | +| Noise estimation | | | | | | | | +| IFFT | | | | | | | | +| <b>SRS</b> | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PT-RS</b> | | | | | | | | +| Sequence detection | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +Figure 7.1.3.4.1-1: AAL\_PUSCH\_FEC Profile + +##### 7.1.3.4.2 AAL\_PUSCH\_HIGH-PHY + +Figure 7.1.3.4.2-1 highlights the set of accelerated functions that defines the AAL\_PUSCH\_HIGH-PHY Profile, which includes the processing of PUSCH data (with or without UCI). + +The set of accelerated functions associated with the processing of PUSCH data is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation +- Channel equalization +- Transform precoding (optional- only required for DFT-s-OFDM waveform) +- Demodulation +- Descrambling +- Rate de-matching +- LDPC decoding +- CRC check + +The AAL\_PUSCH\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.4.2-1: AAL_PUSCH_HIGH-PHY Profile. This block diagram illustrates the processing flow for PUSCH UL data and various PUCCH formats (0, 1, 2/3/4) and PRACH. The flow starts with PUSCH UL data, followed by TB CRC check, CB CRC + CB desegmentation, LDPC decoding, Rate dematching, CB deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE mapping, and IQ decompression*. The PUCCH formats follow similar steps but include UCI processing and different channel estimation methods. PRACH includes preamble detection and peak search. SRS and PT-RS are also shown. The entire process is part of the O-RAN FH (7-2x lower layer split).](22ffc42c30d66b92d27e0c50ad70ab32_img.jpg) + +| L2 + | | | | | | | | +|---------------------------------------|--|--|--|--|--|--|--| +| <b>PUSCH UL data</b> | | | | | | | | +| TB CRC check | | | | | | | | +| CB CRC + CB desegmentation | | | | | | | | +| LDPC decoding | | | | | | | | +| Rate dematching | | | | | | | | +| CB deconcatenation | | | | | | | | +| Descrambling | | | | | | | | +| Demodulation | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE mapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PUCCH format 0 UCI</b> | | | | | | | | +| Sequence detection | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PUCCH format 1 UCI</b> | | | | | | | | +| Demodulation | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PUCCH format 2/3/4 UCI</b> | | | | | | | | +| CRC check | | | | | | | | +| Polar/Block decoding | | | | | | | | +| Rate dematching | | | | | | | | +| Descrambling | | | | | | | | +| Demodulation | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PRACH</b> | | | | | | | | +| Preamble detection + delay estimation | | | | | | | | +| Peak search | | | | | | | | +| Noise estimation | | | | | | | | +| IFFT | | | | | | | | +| <b>SRS</b> | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PT-RS</b> | | | | | | | | +| Sequence detection | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +Figure 7.1.3.4.2-1: AAL\_PUSCH\_HIGH-PHY Profile. This block diagram illustrates the processing flow for PUSCH UL data and various PUCCH formats (0, 1, 2/3/4) and PRACH. The flow starts with PUSCH UL data, followed by TB CRC check, CB CRC + CB desegmentation, LDPC decoding, Rate dematching, CB deconcatenation, Descrambling, Demodulation, IDFT for DFT-s-OFDM, Channel equalization, Channel estimation, RE mapping, and IQ decompression\*. The PUCCH formats follow similar steps but include UCI processing and different channel estimation methods. PRACH includes preamble detection and peak search. SRS and PT-RS are also shown. The entire process is part of the O-RAN FH (7-2x lower layer split). + +Figure 7.1.3.4.2-1 : AAL\_PUSCH\_HIGH-PHY Profile + +##### 7.1.3.4.3 AAL\_PUCCH\_HIGH-PHY + +Figure 7.1.3.4.3.1-1, Figure 7.1.3.4.3.2-1 and Figure 7.1.3.4.3.2-1 highlight the set of accelerated functions that defines the AAL\_PUCCH\_HIGH-PHY Profile, which includes the processing of UCI. + +The set of accelerated functions associated with the processing of PUCCH UCI depends on the PUCCH format being configured by the AAL Application. + +###### 7.1.3.4.3.1 PUCCH format 0 + +The set of accelerated functions associated with the processing of PUCCH UCI using PUCCH format 0 is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Sequence detection + +Image: O-RAN Alliance Logo + +O-RAN.WG6.AAL-GaNP-R004-v11.00 +![AAL_PUCCH_HIGH-PHY Profile (PUCCH format 0) Block Diagram](26e728cf1f9325df2e9a7528c5fa2a7c_img.jpg) + +The diagram illustrates the AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 0) processing pipeline. It shows the processing blocks for different physical channels and signals mapped to the O-RAN FH (7-2x lower layer split) at the bottom and L2+ at the top. + +- PUSCH UL data:** TB CRC check → CB CRC + CB Desegmentation → LDPC decoding → Rate dematching → CB Deconcatenation → Descrambling → Demodulation → IDFT for DFT-s-OFDM → Channel equalization → Channel estimation → RE demapping → IQ decompression\* +- PUCCH format 0 UCI:** Sequence detection → RE mapping → IQ decompression\* +- PUCCH format 1 UCI:** Demodulation → Channel equalization → Channel estimation → RE demapping → IQ decompression\* +- PUCCH format 2/3/4 UCI:** CRC check → Polar/Block decoding → Rate dematching → Descrambling → Demodulation → IDFT for DFT-s-OFDM → Channel equalization → Channel estimation → RE demapping → IQ decompression\* +- PRACH:** Preamble detection + delay estimation → Peak search → Noise estimation → IFFT → Root sequence correlation → RE demapping → IQ decompression\* +- SRS:** Channel estimation → RE demapping → IQ decompression\* +- PT-RS:** Sequence detection → RE demapping → IQ decompression\* + +AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 0) Block Diagram + +**Figure 7.1.3.4.3.1-1: AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 0)** + +#### 7.1.3.4.3.2 PUCCH format 1 + +The set of accelerated functions associated with the processing of PUCCH UCI using PUCCH format 1 is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation +- Channel equalization +- Demodulation + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. +60 + +Image: O-RAN ALLIANCE Logo + +O-RAN.WG6.AAL-GAnP-R004-v11.00 + +![AAL_PUCCH_HIGH-PHY Profile (PUCCH format 1) Diagram](729efb5720a0bc11767164cfa1d4a527_img.jpg) + +The diagram illustrates the High-PHY processing pipeline for various physical channels and signals, showing the mapping from the O-RAN Fronthaul (7-2x lower layer split) at the bottom to the L2+ interface at the top. + +- PUSCH UL data:** IQ decompression\* → RE demapping → Channel estimation → Channel equalization → IDFT for DFT-s-OFDM → Demodulation → Descrambling → CB Deconcatenation → Rate dematching → LDPC decoding → CB CRC + CB Desegmentation → TB CRC check → L2+ +- PUCCH format 0 UCI:** IQ decompression\* → RE demapping → Sequence detection → L2+ +- PUCCH format 1 UCI:** IQ decompression\* → RE mapping → Channel estimation → Channel equalization → Demodulation → L2+ (Highlighted in yellow/orange) +- PUCCH format 2/3/4 UCI:** IQ decompression\* → RE demapping → Channel estimation → Channel equalization → IDFT for DFT-s-OFDM → Demodulation → Descrambling → Rate dematching → Polar/Block decoding → CRC check → L2+ +- PRACH:** IQ decompression\* → RE demapping → Root sequence correlation → IFFT → Noise estimation → Peak search → Preamble detection + delay estimation → L2+ +- SRS:** IQ decompression\* → RE demapping → Channel estimation → L2+ +- PT-RS:** IQ decompression\* → RE demapping → Sequence detection → L2+ + +Note: \* indicates IQ decompression is optional/profile-dependent. + +AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 1) Diagram + +**Figure 7.1.3.4.3.2-1: AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 1)** + +### 7.1.3.4.3.3 PUCCH format 2/3/4 + +The set of accelerated functions associated with the processing of PUCCH UCI using PUCCH format 2/3/4 is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation +- Channel equalization +- Transform precoding (optional- only required for DFT-s-OFDM waveform) +- Demodulation +- Descrambling +- Rate de-matching +- Polar/Block decoding +- CRC check + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. + +61 + +![](dea084f6bb5c3f13476addd074da28e7_img.jpg) + +1 + +| | | | | | | | | | | | | | +|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--|----------------------------------------------------------------------------------------------------------------------------------------|--|------------------------------------------------------------------------------------------------|--|--------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------|-------------------------------------------------------------------------| +| L2 + | | | | | | | | | | | | | +| <b>PUSCH</b><br><b>UL data</b><br>TB CRC check<br>CB CRC + CB Desegmentation<br>LDPC decoding<br>Rate dematching<br>CB Deconcatenation<br>Descrambling<br>Demodulation<br>IDFT for DFT-s-OFDM<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | | <b>PUCCH format 2/3/4</b><br><b>UCI</b><br>CRC check<br>Polar/Block decoding<br>Rate dematching<br>Descrambling<br>Demodulation<br>IDFT for DFT-s-OFDM<br>Channel equalization<br>Channel estimation<br>RE mapping<br>IQ decompression* | | | <b>PUCCH format 1</b><br><b>UCI</b><br>Demodulation<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | <b>PUCCH format 0</b><br><b>UCI</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | | <b>PRACH</b><br>Preamble detection + delay estimation<br>Peak search<br>Noise estimation<br>IFFT<br>Root sequence correlation<br>RE demapping<br>IQ decompression* | <b>SRS</b><br>Channel estimation<br>RE demapping<br>IQ decompression* | <b>PT-RS</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | +| O-RAN FH (7-2x lower layer split) | | | | | | | | | | | | | + +2 + +**Figure 7.1.3.4.3.3-1: AAL\_PUCCH\_HIGH-PHY Profile (PUCCH format 2/3/4)** + +The AAL\_PUCCH\_HIGH-PHY profile is executed in inline acceleration mode. + +##### 7.1.3.4.4 AAL\_PRACH\_HIGH-PHY + +Figure 7.1.3.4.4-1 highlights the set of accelerated functions that defines the AAL\_PRACH\_HIGH-PHY Profile. + +The set of accelerated functions associated with the processing of PRACH preamble is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Root sequence generation and correlation +- IFFT +- Noise estimation +- Peak search for power delay profile +- Preamble detection and delay/timing advance estimation + +![](2c6ff96172dc261a119121358ac82fd8_img.jpg) + +| | | | | | | | | +|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|----------------------------------------------------------------------------------------------------------------------------------------|--|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| L2 + | | | | | | | | +| <b>PUSCH</b><br><b>UL data</b><br>TB CRC check<br>CB CRC + CB Desegmentation<br>LDPC decoding<br>Rate dematching<br>CB Deconcatenation<br>Descrambling<br>Demodulation<br>IDFT for DFT-s-OFDM<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | | | <b>PUCCH format 2/3/4</b><br><b>UCI</b><br>CRC check<br>Polar/Block decoding<br>Rate dematching<br>Descrambling<br>Demodulation<br>IDFT for DFT-s-OFDM<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | | | +| | | <b>PUCCH format 1</b><br><b>UCI</b><br>Demodulation<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | <b>PUCCH format 0</b><br><b>UCI</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | | <b>PRACH</b><br>Preamble detection + delay estimation<br>Peak search<br>Noise estimation<br>IFFT<br>Root sequence correlation<br>RE mapping<br>IQ decompression* | | +| | | | | <b>SRS</b><br>Channel estimation<br>RE demapping<br>IQ decompression* | | <b>PT-RS</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +**Figure 7.1.3.4.4-1: AAL\_PRACH\_HIGH-PHY Profile** + +The AAL\_PRACH\_HIGH-PHY Profile is executed in inline acceleration mode. + +##### 7.1.3.4.5 AAL\_SRS\_HIGH-PHY + +Figure 7.1.3.4.5-1 highlights the set of accelerated functions that defines the AAL\_SRS\_HIGH-PHY Profile. + +The set of accelerated functions associated with the processing of SRS is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation + +![](8a747e4b6d0784428f4707593ae27081_img.jpg) + +| L2 + | | | | | | | | +|---------------------------------------|--|--|--|--|--|--|--| +| <b>PUSCH UL data</b> | | | | | | | | +| TB CRC check | | | | | | | | +| CB CRC + CB Desegmentation | | | | | | | | +| LDPC decoding | | | | | | | | +| Rate dematching | | | | | | | | +| CB Deconcatenation | | | | | | | | +| Descrambling | | | | | | | | +| Demodulation | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PUCCH format 0 UCI</b> | | | | | | | | +| Sequence detection | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PUCCH format 1 UCI</b> | | | | | | | | +| Demodulation | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PUCCH format 2/3/4 UCI</b> | | | | | | | | +| CRC check | | | | | | | | +| Polar/Block decoding | | | | | | | | +| Rate dematching | | | | | | | | +| Descrambling | | | | | | | | +| Demodulation | | | | | | | | +| IDFT for DFT-s-OFDM | | | | | | | | +| Channel equalization | | | | | | | | +| Channel estimation | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PRACH</b> | | | | | | | | +| Preamble detection + delay estimation | | | | | | | | +| Peak search | | | | | | | | +| Noise estimation | | | | | | | | +| IFFT | | | | | | | | +| <b>SRS</b> | | | | | | | | +| Channel estimation | | | | | | | | +| RE mapping | | | | | | | | +| IQ decompression* | | | | | | | | +| <b>PT-RS</b> | | | | | | | | +| Sequence detection | | | | | | | | +| RE demapping | | | | | | | | +| IQ decompression* | | | | | | | | +| O-RAN FH (7-2x lower layer split) | | | | | | | | + +**Figure 7.1.3.4.5-1: AAL\_SRS\_HIGH-PHY Profile** + +The AAL\_SRS\_HIGH-PHY Profile is executed in inline acceleration mode. + +##### 7.1.3.4.6 AAL\_PT-RS-UL\_HIGH-PHY + +Figure 7.1.3.4.6-1 highlights the set of accelerated functions that defines the AAL\_PT-RS-UL\_HIGH-PHY Profile. + +The set of accelerated functions associated with the processing of PT-RS-UL sequence is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Sequence detection + +Image: O-RAN Alliance Logo + +O-RAN.WG6.AAL-GaNp-R004-v11.00 + +![Figure 7.1.3.4.6-1: AAL_PT-RS-UL_HIGH-PHY profile](1fcffcebbafd755a0425238bfb181331_img.jpg) + +Detailed description of Figure 7.1.3.4.6-1: This block diagram illustrates the processing pipeline for different physical channels in the uplink (UL) high-PHY profile. The pipeline starts from the O-RAN FH (7-2x lower layer split) at the bottom and goes up to L2+ at the top. The channels shown are PUSCH UL data, PUCCH format 0 UCI, PUCCH format 1 UCI, PUCCH format 2/3/4 UCI, PRACH, SRS, and PT-RS. Each channel has a stack of processing blocks. For example, PUSCH UL data includes: IQ decompression\*, RE demapping, Channel estimation, Channel equalization, IDFT for DFT-s-OFDM, Demodulation, Descrambling, CB Deconcatenation, Rate dematching, LDPC decoding, CB CRC + CB Desegmentation, and TB CRC check. Other channels have similar stacks with specific blocks like Sequence detection, Polar/Block decoding, Peak search, Noise estimation, IFFT, and Root sequence correlation. The PT-RS channel highlights 'Sequence detection' and 'RE mapping' in yellow/orange boxes. + +Figure 7.1.3.4.6-1: AAL\_PT-RS-UL\_HIGH-PHY profile + +**Figure 7.1.3.4.6-1: AAL\_PT-RS-UL\_HIGH-PHY profile** + +The AAL\_PT-RS-UL\_HIGH-PHY profile is executed in inline acceleration mode. + +### 7.1.3.4.7 AAL\_UPLINK\_HIGH-PHY + +Figure 7.1.3.4.7-1 highlights the set of accelerated functions that defines the AAL\_UPLINK\_HIGH-PHY Profile, this profile includes the aggregation of all the individual uplink channel profiles as follows: + +**PUSCH:** + +- **Data:** see list of accelerated functions associated with the processing of PUSCH data, per section 7.1.3.4.2 +- **DM-RS:** see list of accelerated functions listed in section 7.1.3.4.6, implemented to process DM-RS IQ samples. +- **PT-RS:** see list of accelerated functions listed in section 7.1.3.4.6 + +**PUCCH:** + +- **Format 0:** see list of accelerated functions listed in section 7.1.3.4.3.1 +- **Format 1:** + - o **UCI:** see list of accelerated functions listed in section 7.1.3.4.3.2 + - o **DM-RS:** see list of accelerated functions listed in section 7.1.3.4.6, implemented to process DM-RS IQ samples. +- **Formats 2/3/4:** + - o **UCI:** see list of accelerated functions listed in section 7.1.3.4.3.3 + - o **DM-RS:** see list of accelerated functions listed in section 7.1.3.4.6, implemented to process DM-RS IQ samples. + +**PRACH:** + +- see list of accelerated functions listed in section 7.1.3.4.4 + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. + +65 + +###### SRS: + +- see list of accelerated functions listed in section 7.1.3.4.5 + +The AAL\_UPLINK\_HIGH-PHY Profile is executed in inline acceleration mode. + +![Figure 7.1.3.4.7-1: AAL_UPLINK_HIGH-PHY Profile block diagram showing the flow of data and processing blocks for PUSCH, PUCCH, PRACH, SRS, and PT-RS.](2ef3048df29ee6142187d01b0efe18a6_img.jpg) + +The diagram illustrates the AAL\_UPLINK\_HIGH-PHY Profile architecture. It shows the flow of data and processing blocks for various uplink channels and signals. The top section is labeled 'L2 +'. The main processing blocks are organized into columns representing different channels and signals: PUSCH UL data, PUCCH format 2/3/4 UCI, PUCCH format 1 UCI, PUCCH format 0 UCI, PRACH, SRS, and PT-RS. The blocks are connected by arrows indicating the data flow. The bottom section is labeled 'O-RAN FH (7-2x lower layer split)'. + +| PUSCH UL data | PUCCH format 2/3/4 UCI | PUCCH format 1 UCI | PUCCH format 0 UCI | PRACH | SRS | PT-RS | +|----------------------------|------------------------|----------------------|--------------------|---------------------------------------|--------------------|--------------------| +| TB CRC check | CRC check | | | | | | +| CB CRC + CB desegmentation | Polar/Block decoding | | | | | | +| LDPC decoding | Rate dematching | | | | | | +| Rate dematching | Descrambling | | | Preamble detection + delay estimation | | | +| CB deconcatenation | Demodulation | | | Peak search | | | +| Descrambling | IDFT for DFT-s-OFDM | | | Noise estimation | | | +| Demodulation | Channel equalization | Demodulation | | IFFT | | | +| IDFT for DFT-s-OFDM | Channel estimation | Channel equalization | | Root sequence correlation | | | +| Channel equalization | RE mapping | Channel estimation | Sequence detection | RE mapping | Channel estimation | Sequence detection | +| Channel estimation | IQ decompression* | RE mapping | RE mapping | RE mapping | RE mapping | RE mapping | +| RE mapping | | IQ decompression* | IQ decompression* | IQ decompression* | IQ decompression* | IQ decompression* | +| IQ decompression* | | IQ decompression* | IQ decompression* | IQ decompression* | IQ decompression* | IQ decompression* | + +Figure 7.1.3.4.7-1: AAL\_UPLINK\_HIGH-PHY Profile block diagram showing the flow of data and processing blocks for PUSCH, PUCCH, PRACH, SRS, and PT-RS. + +Figure 7.1.3.4.7-1: AAL\_UPLINK\_HIGH-PHY Profile + +#### 7.1.3.5 O-DU AAL Profiles for mMTC + +##### 7.1.3.5.1 AAL\_NPDSCH\_FEC + +Figure 7.1.3.5.1-1: highlights the set of accelerated functions that define the AAL\_NPDSCH\_FEC Profile. These include: + +- CRC Generation +- Tail-Biting Convolutional Coding +- Rate Matching + +The AAL\_NPDSCH\_FEC Profile is implemented as a look aside accelerator. + +Image: O-RAN Alliance Logo + +O-RAN.WG6.AAL-GAnP-R004-v11.00 + +![Figure 7.1.3.5.1-1: AAL_NPDSCH_FEC Profile block diagram showing processing chains for NPDSCH TB(s), NPDCCH (DCI), NPBCH TB, NPSS/NSSS/NRS, and NPRS/NWUS, leading to O-RAN FH (7-2x lower layer split).](d21941f1aa786639b1022a9d38d00841_img.jpg) + +The diagram illustrates the processing chains for different physical channels in the downlink: + +- NPDSCH TB(s):** TB CRC attachment (accelerated) → Tail Biting Convolutional Coding (accelerated) → Rate matching (accelerated) → CB concatenation → Scrambling → Modulation → Layer mapping → Precoding\* → RE mapping → IQ compression\* +- N PDCCH (DCI):** CRC attachment → Tail Biting Convolutional Coding → Rate matching → Scrambling → Modulation (QPSK) → Precoding\* → RE mapping → IQ compression\* +- NPBCH TB:** PBCH payload generation → CRC attachment → Tail Biting Convolutional Coding → Rate Matching → Scrambling → Modulation → Layer Mapping → Precoding\* → RE mapping → IQ compression\* +- NPSS/NSSS/NRS:** Sequence Generation → Modulation → Precoding\* → RE mapping → IQ compression\* +- NPRS/NWUS:** Sequence Generation → Modulation → Precoding\* → RE mapping → IQ compression\* + +All chains output to O-RAN FH (7-2x lower layer split). Steps marked with \* are optional. + +Figure 7.1.3.5.1-1: AAL\_NPDSCH\_FEC Profile block diagram showing processing chains for NPDSCH TB(s), NPDCCH (DCI), NPBCH TB, NPSS/NSSS/NRS, and NPRS/NWUS, leading to O-RAN FH (7-2x lower layer split). + +**Figure 7.1.3.5.1-1: AAL\_NPDSCH\_FEC Profile** + +### 7.1.3.5.2 AAL\_NPDCCH\_FEC + +Figure 7.1.3.5.2-1 highlights the set of accelerated functions that define the AAL\_NPDCCH\_FEC Profile. These include + +- CRC Generation +- Tail-Biting Convolutional Coding +- Rate Matching + +The AAL\_NPDCCH\_FEC Profile is implemented as a look aside accelerator. + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. + +67 + +![](3cb3e39773b70e6ce0a91b75ac973087_img.jpg) + +| L2+ | | | | | | +|-----------------------------------|----------------------------------|----------------------------------|----------------------|---------------------|--| +| <b>NPDSCH TB(s)</b> | | <b>NPBCH TB</b> | | | | +| TB CRC attachment | | PBCH payload generation | | | | +| Tail Biting Convolutional Coding | | CRC attachment | | | | +| Rate matching | <b>N PDCCH (DCI)</b> | Tail Biting Convolutional Coding | | | | +| CB concatenation | CRC attachment | Rate Matching | | | | +| Scrambling | Tail Biting Convolutional Coding | Scrambling | <b>NPSS/NSSS/NRS</b> | <b>NPRS/NWUS</b> | | +| Modulation | Rate matching | Modulation | Sequence Generation | Sequence Generation | | +| Layer mapping | Scrambling | Layer Mapping | Modulation | Modulation | | +| Precoding* | Modulation (QPSK) | Precoding* | | | | +| RE mapping | Precoding* | RE mapping | | | | +| IQ compression* | RE mapping | IQ compression* | | | | +| | IQ compression* | | | | | +| O-RAN FH (7-2x lower layer split) | | | | | | + +Figure 7.1.3.5.2-1: AAL\_NPDCCH\_FEC Profile + +##### 7.1.3.5.3 AAL\_NPBCH\_FEC + +Figure 7.1.3.5.3-1 highlights the set of accelerated functions that define the AAL\_NPBCH\_FEC Profile. These include + +- CRC Generation +- Tail-Biting Convolutional Coding +- Rate Matching + +The AAL\_NPBCH\_FEC Profile is implemented as a look aside accelerator. + +![](1535c252e46507edb528d95576205808_img.jpg) + +| | | | | | | +|-----------------------------------|--|-----------------------------------------|--|----------------------|---------------------| +| L2+ | | | | | | +| <b>NPDSCH TB(s)</b> | | <b>NPBCH TB</b> | | | | +| TB CRC attachment | | PBCH payload generation | | | | +| Tail Biting Convolutional Coding | | <b>CRC attachment</b> | | | | +| Rate matching | | <b>Tail Biting Convolutional Coding</b> | | | | +| CB concatenation | | <b>Rate Matching</b> | | | | +| Scrambling | | Scrambling | | <b>NPSS/NSSS/NRS</b> | <b>NPRS/NWUS</b> | +| Modulation | | Modulation | | Sequence Generation | Sequence Generation | +| Layer mapping | | Layer Mapping | | Modulation | Modulation | +| Precoding* | | Precoding* | | | Precoding* | +| RE mapping | | RE mapping | | | RE mapping | +| IQ compression* | | IQ compression* | | | IQ compression* | +| O-RAN FH (7-2x lower layer split) | | | | | | + +Figure 7.1.3.5.3-1: AAL\_NPBCH\_FEC Profile + +##### 7.1.3.5.4 AAL\_NPUSCH\_FEC + +Figure 7.1.3.5.4-1 highlights the set of accelerated functions that define the AAL\_NPUSCH\_FEC Profile. These include + +- CRC Generation +- Turbo Decoding +- Rate Matching + +The AAL\_NPUSCH\_FEC Profile is implemented as a look aside accelerator. + +**O-RAN** +ALLIANCE + +O-RAN.WG6.AAL-GaNP-R004-v11.00 + +![Figure 7.1.3.5.4-1: AAL_NPUSCH_FEC Profile](9e099a1139b4e9a1d7f5a2c775d8b548_img.jpg) + +The diagram illustrates the AAL\_NPUSCH\_FEC Profile with the following processing blocks from bottom to top, starting from O-RAN FH (7-2x lower layer split): + +- IQ decompression\*** (applied to all paths: NPUSCH UL data, DMRS with PUSCH Format 1 and Format 2, PUSCH Format 2 UCI, and NPRACH) +- RE demapping** (applied to all paths) +- NPUSCH UL data path:** Channel estimation → Channel equalization → IDFT for DFT-s-OFDM → Layer Demapping → Demodulation → Descrambling → Rate dematching → Turbo decoding → CRC check → UL data → L2+ +- DMRS with PUSCH Format 1 and Format 2 path:** Channel Estimation +- PUSCH Format 2 UCI path:** Channel estimation → Channel equalization → Demodulation → Descrambling → Rate dematching → Channel decoding → AC-NACK detection → L2+ +- NPRACH path:** Root sequence correlation → IFFT → Noise estimation → Peak search → Preamble detection + delay estimation → L2+ + +Figure 7.1.3.5.4-1: AAL\_NPUSCH\_FEC Profile + +**Figure 7.1.3.5.4-1: AAL\_NPUSCH\_FEC Profile** + +## 7.2 O-CU AAL Profiles + +The O-CU AAL profiles shall be part of further study for O-RAN WG6. + +© 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. + +70 + +# Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2024.11.25 | 10.00.03 | Update AAL FFT Profile functionality | +| 2024.11.25 | 10.00.02 | Introduce AAL AF Bypass functionality in 6.2.5. | +| 2024.10.09 | 10.00.01 | Introducing a definition for what it means to have a declarative approach in new clause 6.2.7 | +| 2024.07.19 | 09.00.05 | Minor editorial fix to figure 4.2.2-1 architecture diagram, change O1dms to O1. | +| 2024.07.04 | 09.00.04 | Editorial changes to update figures throughout the document.<br><br>Updated the number of the LPU's on architecture diagram. Terminate IMS interface to HAM in example HAM software deployment scenarios. | +| 2024.07.04 | 09.00.03 | Clause 4.2.3 add requirement stating that the scope of the HAM identifier is within an O-Cloud instance. | +| 2024.07.04 | 09.00.02 | Adding picture for inline example in General Aspects section as it can be confusing for reader as inline is missing from general description. | +| 2024.05.09 | 09.00.01 | Editorial changes for removal of "cloudified RAN" which is not defined on higher levels | +| 2024.03.22 | 08.00.06 | Updated with minor editorial fixes for publication. | +| 2024.03.07 | 08.00.05 | Modified high level architecture diagram with deletion of the interface between DMS and NF so that readers are not confused about API which is not existent yet and is out of scope of this document. | +| 2024.03.07 | 08.00.04 | Updates from CR <a href="#">ERI-2024.1.23-WG6-CR-0046-AAL GAP CADS reference correction.docx</a><br><br>1. "VOID" the reference to the CADS TR in the normative reference section.<br><br>2. Change the reference to CADS for O-Cloud Platform Software to a reference of the WG1 OAD TS.<br><br>3. Change the reference to CADS for the synchronization topologies to the WG4 CUS TS. | +| 2024.03.07 | 08.00.03 | 1. Correct definitions of Accelerated Function and AAL Profile to remove the constraint that it be a "Cloudified Network Function" (that term is no longer defined anyway).<br><br>2. Add clarification text to figure 4.2-1 to point out that support of O1 by the AAL Application is not a requirement.<br><br>3. Move the text at the bottom of the terms and conditions section to section 4.2. The text is unchanged.<br><br>4. Update Figure 4.2-5 to change "NF Application" to "AAL Application". | +| 2024.01.18 | 08.00.02 | To improve readability and improve clarity, existing text was moved to different clauses and additional clarification points were considered from <a href="#">DCM-2023.10.24-WG6-GAP-updates section 2.2 v03</a> | +| 2024.01.18 | 08.00.01 | Updated diagrams to align format. | + +| | | | +|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.11.28 | 08.00 | Published from version 07.00.09 | +| 2023.10.14 | 07.00.09 | Editorial Updates, fix broken reference. | +| 2023.10.11 | 07.00.08 | Update format to latest O-RAN TS template | +| 2023.10.11 | 07.00.07 | Add text that describes the DMS to AAL Application interface.<br><a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/QCM-2023.10.24-WG6-CR-0048-Add_AAL_DMS_Description.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/QCM-2023.10.24-WG6-CR-0048-Add_AAL_DMS_Description.docx?api=v2</a><br><br>Editorial updates. | +| 2023.10.11 | 07.00.06 | Avoid mixing definitions with characteristics and requirements, clause 1.3.1 and 4.1. Updated definition section to provide additional clarity. | +| 2023.09.11 | 07.00.05 | Editorial updates in clauses 1.2, 1.3.2, 2.1, 3.1,4.2<br><a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/DCM-2023.10.24-WG6-GAP_editorial_updates_v03.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/DCM-2023.10.24-WG6-GAP_editorial_updates_v03.docx?api=v2</a> | +| 2023.09.11 | 07.00.04 | Removed reference to alarms which are no longer in scope of this document. | +| 2023.09.11 | 07.00.03 | Add example diagrams of how AAL Software drivers are deployments, added clarification on how AAL SW drivers are installed and managed.<br><br><a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/INT-10-06-23-WG6-CR-18-AAL-GAnP-driver-deployments-clarification.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/INT-10-06-23-WG6-CR-18-AAL-GAnP-driver-deployments-clarification.docx?api=v2</a> | +| 2023.09.11 | 07.00.02 | Captured the architectural aspects for use of AAL APIs without impacting the O-RAN architecture.<br><a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/ERI.AO-2023.08.03-WG6-CR-006-AAL%20GAP%20Agreements%20to%20support%20open%20multi-vendor%20Interfaces%20for%20AAL%20APIs.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/ERI.AO-2023.08.03-WG6-CR-006-AAL%20GAP%20Agreements%20to%20support%20open%20multi-vendor%20Interfaces%20for%20AAL%20APIs.docx?api=v2</a> | +| 2023.09.11 | 07.00.01 | Add description of a software repository use by HAM in section 1.3.1.<br><a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/ERI-2023.08.08-WG6-CR-005-AAL%20GAP%20SW%20Repo%20Clarifications.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/ERI-2023.08.08-WG6-CR-005-AAL%20GAP%20SW%20Repo%20Clarifications.docx?api=v2</a> | +| 2023.14.07 | 06.00.07 | Implemented CR from <a href="https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/INT-VMW-06-30-23-WG6-CR-AAL-GAnP-Editorial-rearrange-principles-and-arch_v1.docx?api=v2">https://oranalliance.atlassian.net/wiki/download/attachments/2210398415/INT-VMW-06-30-23-WG6-CR-AAL-GAnP-Editorial-rearrange-principles-and-arch_v1.docx?api=v2</a> Move 2.5 to chapter 3 and move 3.1 & 3.2 to chapter 2 to better align with chapter contents. | +| 2023.14.07 | 06.00.06 | Implemented CR from <a href="#">SLA-2023.05.16-ORAN.WG6-CR 03-AAL-GAnP-R003-v06.00.doc</a> . State that HAM is part of and is integrated along with O-Cloud Platform software | +| 2023.30.06 | 06.00.05 | Implemented CR from <a href="#">VMW-2023.05.31-WG6-CR-AAL%20Architecture%20in%20GAnP.docx</a> | +| 2023.30.06 | 06.00.04 | Implemented CR from <a href="#">SLA-2023.05.17-ORAN.WG6.CR%20004-AAL-GAnP-R003-v06.00.docx</a> | +| 2023.30.06 | 06.00.03 | Implemented CR from <a href="#">DCM-2023.05.17-WG6-AAL-ETSI</a> | +| 2023.30.06 | 06.00.02 | Implemented CR from <a href="#">QCM-2023.04-24-WG6-CR-0034-AAL-GAnP-Clarify-AAL-Mgmt-Functions.docx</a> | + +| | | | +|------------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.27.04 | 06.00.01 | Implemented CR from <a href="#">ERI-202304.02-WG6_CR_AAL-GAnP Editorial.docx</a> and various editorial comments from <a href="#">July Train WIKI</a> | +| 2023.10.03 | 05.00.04 | Definition of new FFT Profile | +| 2023.10.03 | 05.00.03 | Describe the chaining of AAL Profile Instances in Sec 4.1.6 AAL-LPU Principles | +| 2023.10.03 | 05.00.02 | Modification of Figure 2.7 and 2.8 in GAnP, changes to sections 2.5.2 and 5.1.3.1.2.. | +| 2022.09.12 | 05.00.01 | Implemented CR from QCM-24 Editorial modifications to correct AAL terms | +| 2022.11.07 | 04.00.04 | Implemented CR from INT-0014 (example AAL-LPU mapping diagrams) | +| 2022.11.07 | 04.00.03 | Implemented CR from QCM-0013 (ER Diagram) | +| 2022.11.07 | 04.00.02 | Implemented CR from QCM-0020 (AAL App Definition) | +| 2022.10.25 | 04.00.01 | Implemented CRs NOK-0001 (AALProfile_v02) | +| 2022.09.02 | 04.00 | Final version 04.00 | \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/6b0981d61b4ca670760d6b7a430d72ad_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/6b0981d61b4ca670760d6b7a430d72ad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5080600e3790a779a1e25e3408a0657843949d55 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/6b0981d61b4ca670760d6b7a430d72ad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:de3a98dc46c41e5779668d38ff69c4b5ab78597e7fe620f51754bb01a72a4a71 +size 152163 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/bacb1df1351b0628606d0767adbb764b_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/bacb1df1351b0628606d0767adbb764b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cda5820ed4cbb81b88f88d5c9f8db15ac8ded3d6 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/bacb1df1351b0628606d0767adbb764b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f2988afe3d1cf120f965e2ab1eb4622aa576c6bebb4c506c57c161c07242e339 +size 158929 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/f11c22832f1b704bc78d6534ae671707_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/f11c22832f1b704bc78d6534ae671707_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..177351ab5ef5b4ac9c28fee6595310aa3c7c929b --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/f11c22832f1b704bc78d6534ae671707_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:018b00f084ea7ed43fdf85c27fd850157cebe839c4f8c5fa879c60df49e9c2a5 +size 4512 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/raw.md b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..65efe8076a4b14a8ef243d9d6cccc0ae96813400 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00/raw.md @@ -0,0 +1,1766 @@ + + +# **O-RAN Working Group 6 (Cloudification and Orchestration Workgroup) Acceleration Abstraction Layer High-PHY Profiles** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | | +|----|--------------------------------------------------------------------------------------|----| +| 1 | Contents | | +| 2 | List of figures ..... | 3 | +| 3 | List of tables ..... | 3 | +| 4 | Foreword..... | 3 | +| 5 | Modal verbs terminology ..... | 4 | +| 6 | Executive summary ..... | 4 | +| 7 | Introduction ..... | 4 | +| 8 | 1 Scope ..... | 5 | +| 9 | 2 References ..... | 5 | +| 10 | 2.1 Normative references ..... | 5 | +| 11 | 2.2 Informative references ..... | 5 | +| 12 | 3 Definition of terms, symbols and abbreviations ..... | 6 | +| 13 | 3.1 Terms ..... | 6 | +| 14 | 3.2 Symbols ..... | 6 | +| 15 | 3.3 Abbreviations ..... | 6 | +| 16 | 4 Overview ..... | 7 | +| 17 | 4.1 Purpose ..... | 7 | +| 18 | 4.2 Document Structure ..... | 8 | +| 19 | 5 AALI Configuration and Management ..... | 9 | +| 20 | 5.1 Introduction..... | 9 | +| 21 | 5.2 Summary of Capabilities reported through the AALI-C-Mgmt Interface..... | 9 | +| 22 | 6 AAL Profile Specifications ..... | 10 | +| 23 | 6.1 Profile Specifications Overview ..... | 10 | +| 24 | 6.1.1 Naming..... | 10 | +| 25 | 6.2 O-DU AAL_DOWNLINK_High-PHY Profile Specification ..... | 10 | +| 26 | 6.2.1 Profile Operation ..... | 10 | +| 27 | 6.2.2 Summary of Capabilities ..... | 11 | +| 28 | 6.2.2b Summary of Configuration..... | 13 | +| 29 | 6.2.3 PDSCH Channel Model ..... | 14 | +| 30 | 6.2.4 PDCCH Channel Model ..... | 22 | +| 31 | 6.2.5 CSI-RS Channel Model..... | 27 | +| 32 | 6.2.6 SSB Model ..... | 29 | +| 33 | 6.2.7 Beamforming..... | 34 | +| 34 | 6.3 O-DU AAL_UPLINK_High-PHY Profile Specification..... | 36 | +| 35 | 6.3.1 Profile Operation ..... | 36 | +| 36 | 6.3.2 Summary of Capabilities ..... | 37 | +| 37 | 6.3.2b Summary of Configuration..... | 39 | +| 38 | 6.3.3 PUSCH Channel Model ..... | 41 | +| 39 | 6.3.4 PUCCH Channel Model ..... | 48 | +| 40 | 6.3.5 SRS Channel Model ..... | 57 | +| 41 | 6.3.6 PRACH Channel Model ..... | 60 | +| 42 | 6.3.7 Beamforming..... | 62 | +| 43 | Annex A [informative] Stage-3 Support for AAL_DOWNLINK_High-PHY and AAL_UPLINK_High- | | +| 44 | PHY using FAPI ..... | 65 | +| 45 | History ..... | 68 | +| 46 | | | +| 47 | | | + +# List of figures + +| | | +|---------------------------------------------------|---| +| Figure 4.1-1: AAL_DOWNLINK_High-PHY Profile ..... | 7 | +| Figure 4-1-2: AAL_UPLINK_High-PHY Profile ..... | 8 | + +# List of tables + +| | | +|---------------------------------------------------------------------------------------------|----| +| Table 5.2-1: High-PHY Profile Capabilities Reported through the AALI-C-Mgmt Interface ..... | 9 | +| Table 5.2-2: Attribute Properties for Carrier Group ..... | 9 | +| Table 6.2.2-1: Sample AAL_DOWNLINK_High-PHY Profile Capabilities ..... | 11 | +| Table 6.2.3.2-1: PDSCH Data Parameters ..... | 15 | +| Table 6.2.3.2-2: PDSCH DM-RS Parameters ..... | 20 | +| Table 6.2.5.2: CSI-RS Parameters ..... | 28 | +| Table 6.2.6.2-2: PBCH DM-RS Parameters ..... | 33 | +| Table 6.2.6.2-3: PSS & SSS Parameters ..... | 33 | +| Table 6.2.7.2-1: Weight-based Dynamic Beamforming Parameters for Downlink ..... | 35 | +| Table 6.2.7.4-1: Channel-Information-Based Beamforming Parameters for Downlink ..... | 36 | +| Table 6.3.2-1: Sample AAL_UPLINK_High-PHY Profile Capabilities ..... | 37 | +| Table 6.3.2b-1: Sample Carrier Configurations pertinent to AAL_UPLINK_High-PHY ..... | 39 | +| Table 6.3.3.2-1: PUSCH Data Parameters ..... | 42 | +| Table 6.3.3.2-2: PUSCH DM-RS Parameters ..... | 46 | +| Table 6.3.3.2-3: PUSCH PT-RS Parameters ..... | 47 | +| Table 6.3.4.2-1: PUCCH Format 0 Parameters ..... | 50 | +| Table 6.3.4.2-3: PUCCH Format 1 DM-RS Parameters ..... | 52 | +| Table 6.3.4.2-4: PUCCH Formats 2/3/4 Parameters ..... | 53 | +| Table 6.3.4.2-5: PUCCH Formats 2/3/4 DM-RS Parameters ..... | 56 | +| Table 6.3.5.2-1: SRS Parameters ..... | 57 | +| Table 6.3.6.2-1: PRACH Parameters ..... | 60 | +| Table 6.3.7.2-1: Weight-based Dynamic Beamforming Parameters for Uplink ..... | 63 | +| Table 6.3.7.4-1: Channel-Information-Based Beamforming Parameters for Downlink ..... | 63 | + +# Foreword + +This Technical Specification (TS) has been produced by WG6 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- Executive summary + +This document provides the description of the requirements and stage-2 information models to implement an Acceleration Abstraction Layer (AAL) for the High-PHY functionality hosted by an AAL-LPU that is associated with an O-RAN Distributed Unit (O-DU). Informative examples of stage-3 implementations are described in informational Annexes of this present document. + +# --- Introduction + +This document specifies how to accelerate the High-PHY functionality of an O-DU where the High-PHY Acceleration Function (AF) is hosted on an AAL-LPU that is assigned to the AAL Application that is part of the O-DU. This document also specifies a set of AAL Profiles and procedures for utilizing the AALI Common Management (AALI-C-Mgmt) and Application (AALI-C-App) interfaces to convey the information elements specified by the AAL Profiles. + +# 1 Scope + +The present document specifies the requirements and stage-2 information models for the AAL\_DOWNLINK\_High-PHY and the AAL\_UPLINK\_High-PHY Profiles. Informative examples of stage-3 implementations for the AAL Profiles specified in this present document are described in informational Annexes of this present document. + +# 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] Void +- [2] Void +- [3] Voic +- [4] 3GPP TS 38.211: "NR; Physical channels and modulation". +- [5] 3GPP TS 38.212: "NR; Multiplexing and channel coding". +- [6] 3GPP TR 38.300: "NR; NR and NG-RAN Overall Description". +- [7] O-RAN WG6: Acceleration Abstraction Layer General Aspects and Principles, v06.00, November 2023 +- [8] O-RAN WG4 Control, User and Synchronization Plane Specification, v14.00, November 2023 +- [9] Void +- [10] Void +- [11] Acceleration Abstraction Layer AAL Profile - MUMIMO BeamForming/Precoder Calculation, v01.00, February 2020 +- [12] O-RAN WG6 Acceleration Abstraction Layer Common API v06.00, November 2023 + +## 2.2 Informative references + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] SCF 222: "5G FAPI: PHY API Specification", v07.00, August 2023 +- [i.2] SCF 223: "5G FAPI: Front-End Unit API Specification", v05.00, August 2023 + +1 + +# --- 2 3 Definition of terms, symbols and abbreviations + +# 3 3.1 Terms + +4 For the purposes of the present document, the terms given in [7] apply. + +# 5 3.2 Symbols + +6 For the purposes of the present document, the symbols given in [7] apply. + +# 7 3.3 Abbreviations + +8 For the purposes of the present document, the terms and definitions given in the O-RAN Acceleration Abstraction +9 Layer General Aspects and Principles [7] and the following abbreviations apply: + +| | | | +|----|------|------------------------------------------| +| 10 | AALI | Acceleration Abstraction Layer interface | +| 11 | CB | Code Block | +| 12 | 3GPP | 3rd Generation Partnership Project | +| 13 | OFH | O-RAN Front Haul | +| 14 | O-CU | O-RAN Centralized Unit | +| 15 | O-DU | O-RAN Distributed Unit | +| 16 | O-RU | O-RAN Radio Unit | +| 17 | TB | Transport Block | +| 18 | | | + +# 4 Overview + +## 4.1 Purpose + +The AAL General Aspects and Principles is described in [7] including a high level architecture of the AAL and definition of the AAL Profiles. This document details the AAL specification consisting of the requirements, information model and description of the interface to implement an AALI for the AAL\_DOWNLINK\_High-PHY and AAL\_UPLINK\_High-PHY profiles. + +NOTE: The present document requires inline accelerators supporting High-PHY profiles in inline acceleration mode to implement both AAL\_DOWNLINK\_High-PHY and AAL\_UPLINK\_High-PHY profiles. Support for partial profiles is for FFS. + +These profiles are illustrated below: + +![Figure 4.1-1: AAL_DOWNLINK_High-PHY Profile block diagram showing the flow from L2+ through various processing blocks for PDSCH, PBCH, PDCCH, and CSI-RS/TRS, ending with O-RAN FH (7-2x lower layer split).](bacb1df1351b0628606d0767adbb764b_img.jpg) + +The diagram illustrates the AAL\_DOWNLINK\_High-PHY Profile architecture. It shows the flow of data through various processing blocks, organized into columns for different channels and signals. The top layer is labeled L2+. The main processing blocks are arranged in columns: PDSCH TB(s), PBCH TB, PDCCH (DCI), PSS/SSS, and CSI-RS/TRS. The PDSCH TB(s) column includes TB CRC attachment, CB segmentation + CRC attachment, LDPC encoding, Rate matching, CB concatenation, Scrambling, Modulation, Layer mapping, Precoding\*, and RE mapping. The PBCH TB column includes PBCH payload generation, Scrambling, TB CRC attachment, Polar encoding, Rate matching, Data scrambling, Modulation (QPSK), Precoding\*, and RE mapping. The PDCCH (DCI) column includes CRC attachment, Polar encoding, Rate matching, Scrambling, Modulation (QPSK), Precoding\*, and RE mapping. The PSS/SSS column includes Sequence generation, Modulation, Precoding\*, and RE mapping. The CSI-RS/TRS column includes Sequence Generation, Modulation, Precoding\*, and RE mapping. The bottom layer is labeled O-RAN FH (7-2x lower layer split). The diagram also shows the PDSCH DM-RS /PT-RS and PDCCH DM-RS blocks, which are used for channel estimation and synchronization. + +Figure 4.1-1: AAL\_DOWNLINK\_High-PHY Profile block diagram showing the flow from L2+ through various processing blocks for PDSCH, PBCH, PDCCH, and CSI-RS/TRS, ending with O-RAN FH (7-2x lower layer split). + +Figure 4.1-1: AAL\_DOWNLINK\_High-PHY Profile + +![](6b0981d61b4ca670760d6b7a430d72ad_img.jpg) + +| | | | | | | | | | | | +|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--|-------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------| +| L2+ | | | | | | | | | | | +| <b>PUSCH Data</b><br>TB CRC check<br>CB CRC + CB desegmentation<br>LDPC decoding<br>Rate dematching<br>CB de-concatenation<br>Descrambling<br>Demodulation<br>IDFT for DFT-s OFDM<br>Channel equalization<br>Channel estimation<br>RE demapping<br>IQ decompression* | | | <b>PUSCH DM-RS/PT-RS</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | <b>PUCCH Format 0 UCI</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | <b>PUCCH Format 1 UCI</b><br>De-modulation<br>Channel equalization<br>Channel Estimation<br>RE demapping<br>IQ decompression* | <b>PUCCH Format 1 DM-RS</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | <b>PUCCH Format 2/3/4 UCI</b><br>CRC Check<br>Polar/Block decoding<br>Rate dematching<br>De-scrambling<br>De-modulation<br>IDFT for DFT-s OFDM<br>Channel equalization<br>Channel Estimation<br>RE demapping<br>IQ decompression* | <b>PUCCH Format 2/3/4 DM-RS</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | <b>PRACH</b><br>Preamble detection & delay estimation<br>Peak search<br>Noise estimation<br>IFFT<br>Root Sequence correlation<br>RE demapping<br>IQ decompression* | <b>SRS</b><br>Sequence detection<br>RE demapping<br>IQ decompression* | +| O-RAN FH (7-2x lower layer split) | | | | | | | | | | | + +Figure 4-1-2: AAL\_UPLINK\_High-PHY Profile + +## 4.2 Document Structure + +This present document is structured as follows: Clause 4 presents the overview and main purpose of this specification. Clause 5 will present the high level AALI configuration and management principles for the AAL\_DOWNLINK\_High-PHY and AAL\_UPLINK\_High-PHY Profiles. Clause 6 presents the Profile Overview for these two profiles, sample capabilities, inputs, and outputs as well as AAL-LPU parameters for the channels constituting the profiles. + +# 5 AALI Configuration and Management + +## 5.1 Introduction + +The AALI-C-Mgmt APIs specified in [12] are used to configure the AAL Profiles specified in the present document. The AALI-C-App operations and events specified in [12] are used by the AAL Application to convey the AAL Profile's information elements specified in the present document. + +## 5.2 Summary of Capabilities reported through the AALI-C-Mgmt Interface + +Table 5.2-1 contains a list of capabilities for the AAL-Profiles specified in this present document. The reporting of these capabilities is optional and may be reported through the AALI-C-Mgmt interface as inputs to assist management systems in reconciling the configuration of the AAL-Profile with its capabilities along with any capability extensions. These capabilities are also used in the assignment of the AAL Application with an AAL-LPU supporting the AAL-Profiles specified in this present document. + +**Table 5.2-1: High-PHY Profile Capabilities Reported through the AALI-C-Mgmt Interface** + +| Capability name | Data Type/Description | Properties | Applicable AAL-Profiles | +|-----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------| +| carrierGroup | <b>Data Type:</b> array<br><br><b>Description:</b> The carrier groups supported by the AAL-Profile. A carrier is set of carriers that can pool capabilities (e.g., bandwidth layer). | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification True<br>nullable: False<br>x-isOrdered: False<br>title: Numerologies<br>minItems: 1<br>uniqueItems: True<br>items: Numerology | AAL_DOWNLINK_High-PHY<br><br>AAL_UPLINK_High-PHY | + +**Table 5.2-2: Attribute Properties for Carrier Group** + +| Attribute name | Data Type/Description | Properties | +|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| id | <b>Data Type:</b> string<br><br><b>Description:</b> The identifier of the carrier group. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification True<br>nullable: False | +| supportedNumerologies | <b>Data Type:</b> array<br><br><b>Description:</b> The list of supported numerologies as described in table 4.2-1/3GPP TS 38.211 [4]. | x-inventoryNotification True<br>nullable: False<br>format: integer8<br>minimum: 0<br>maximum: 4 | +| numCarriers | <b>Data Type:</b> integer<br><br><b>Description:</b> Number of carriers for this carrier group. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification True<br>nullable: False<br>format: integer8<br>minimum: 1<br>maximum: 255 | +| bandwidthLayers | <b>Data Type:</b> integer<br><br><b>Description:</b> The value is the aggregate bandwidth layers across all carriers in this carrier group. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification True<br>nullable: False | + +| Attribute name | Data Type/Description | Properties | +|----------------|-----------------------|---------------------------------------| +| | | format: integer64<br>x-units: HzLayer | + +# 6 AAL Profile Specifications + +## 6.1 Profile Specifications Overview + +This section contains information for each AAL Profile that is specified in this present document. An AAL Profile may provide APIs for a specific profile configuration that may be required in addition to the general AAL configuration APIs. AAL Profile specific configuration shall be done on a per AAL-LPU basis. Each AAL Profile shall define a list of capabilities that will be used to define the operations supported by the AAL-LPU. + +A normative stage-3 definition for this High-PHY Profile specification is FFS and could leverage aspects of various options including but not limited to SCF-222. + +An informative example of one possible mapping of the stage-2 HI-PHY Profile in this document is provided in Annex A. + +### 6.1.1 Naming + +Parameters and capabilities based on this stage-2 specification shall follow the following naming guidelines: + +- Parameter and capability names shall start with a lowercase letter; +- No spaces may be used in the names; +- The names shall consist only of letters and digits and hyphens; +- The first letter of each non-initial word in a name shall be capitalized. +- Acronyms in the beginning of a parameter are lower case, uppercase otherwise +- Acronyms are hyphenated from preceding or succeeding upper case + +## 6.2 O-DU AAL\_DOWNLINK\_High-PHY Profile Specification + +This profile provides acceleration functionality for the following channels and signals: + +- PDSCH (including Data, DM-RS and PT-RS) +- PDCCH (including Data and DM-RS) +- CSI-RS +- SSB (Including PSS, SSS and PBCH) + +This clause presents parametrization for each of these channels and signals, and pertinent carrier configuration. + +### 6.2.1 Profile Operation + +The AAL\_DOWNLINK\_High-PHY Profile interface shall work on a slot basis, where the slot, numerology and SFN are signaled for the API. + +The input data is specific to each downlink channel composing the profile. The output data is a set of C/U-Plane O-RAN Fronthaul (OFH) packets [8]. + +The AAL-LPU interfaces directly with the OFH and is responsible for handling its exchange of information with OFH. + +As much as possible, parameter redundancy should be avoided. Where this is not possible, the AAL-LPU shall assume that redundant parameters are consistent. + +### 6.2.2 Summary of Capabilities + +The AAL\_DOWNLINK\_High-PHY Profile capabilities shall be reported to the application. + +Table 6.2.2-1 lists a subset of the AAL\_DOWNLINK\_High-PHY profile capabilities that should be reported to the application with respect to the acceleration of the various channel functionality and interaction. + +NOTE: Additional capabilities can also be reported by the AALI implementation. + +AALI-P capapbi + +**Table 6.2.2-1: Sample AAL\_DOWNLINK\_High-PHY Profile Capabilities** + +| Capability | Short summary | 3GPP Spec Reference | +|--------------------------|--------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------| +| 3gpp-Release | Releases of 3GPP Specifications that are used. For example, Release 16, Release 17 | <a href="https://www.3gpp.org/specifications/work-plan">https://www.3gpp.org/specifications/work-plan</a> | +| maxPDSCH-TB-PerSlot | Number of PDSCH TB(s) per slot | Outside the scope of 3GPP | +| pdsch-CB-CRC | Supported with CB CRC caching in AAL-LPU, Supported with CB CRC reporting to L1, or Not supported | Outside the scope of 3GPP | +| cyclicPrefix | Normal, Extended or either | 3GPP TS 38.211, sec 4.2 | +| subcarrierSpacing-DL | 15, 30, 60, 120, 240 kHz; can be channel-specific. | 3GPP TS 38.211, sec 4.2 | +| supportedBandwidth-DL | 5, 10, 15, ... MHz | 3GPP TS 38.104, sec 5.3 | +| pdsch-MappingType | A, B or both | 3GPP TS 38.211, sec 7.4.1.1.2 | +| pdsch-AllocationType | 0, 1 or both | 3GPP TS 38.214, sec 5.1.2.2 | +| pdsch-VRB-ToPRBMapping | interleaved, non-interleaved or both | 3GPP TS 38.211, sec 7.3.1.6 | +| pdsch-DMRS-ConfigTypes | 1, 2 or both | 3GPP TS 38.211, sec 7.4.1.1.2 | +| pdsch-DMRS-AdditionalPos | pos0-pos3 | 3GPP TS 38.211, sec 6.4.1.1.3 | +| pdsch-DMRS-MaxLength | 1 or 2 | 3GPP TS 38.211, sec 7.4.1.1.2 | +| pdsch-CBG | Supported with TB CRC caching in AAL-LPU, Supported with TB CRC reporting to the AAL Application, or Not supported | 3GPP TS 38.212, sec 5.4.2.1, 7.3.1.2.2 | +| maxModulationOrderDL | QPSK, 16-QAM, etc. | 3GPP TS 38.214, sec 5.14.3 | +| pdsch-PTRS | Supported or not | 3GPP TS 38.211, sec 7.4.1.2 | +| maxCORESETsPerSlot | Maximum number of CORESETs per slot | Outside the scope of 3GPP | + +| | | | +|-----------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------| +| cce-MappingType | Interleaved or not | 3GPP TS 38.211, sec 7.3.2.2 | +| precoderGranularityCORESET | Wideband (all contiguous RBs) or same as REG bundle | 3GPP TS 38.211, sec 7.3.2.2 | +| coreset-OutsideFirst3OfdmSymbols | Supported or not | 3GPP TS 38.213, sec 13 | +| pdcch-PrecoderSupport | Short Cyclic Delay Diversity, Precoder Cycling, None, etc. | Outside the scope of 3GPP | +| ssb-RateMatch | Rate Match around SSB: supported or not | | +| csi-RS-RM | Rate Match around CSI-RS: Supported or not | | +| rm-PatternTypeAndMethod | Rate Match around PrbSymbPattern: Bitmp, Coreset, Either or Neither | | +| pdcch-RateMatch | Rate Match around PDCCH: Supported or not | | +| lte-CRS-RM-Method | Rate Match around LTE CRS: Supported by static configuration, by explicit slot indication, not supported | | +| maxNumCarriersBW-LayersProduct DL | Maximum bandwidth*layers product support for forming joint precoders across bandwidth, and across baseband antenna ports. Includes the option of “no support” | Outside the scope of 3GPP | +| spatialMUX-PerDL-ChannelType-DL | Ability to spatially multiplex same or different channel types (PDSCH, PDCCH, etc.). Includes the option of “no support” | Outside the scope of 3GPP | +| maxNum-MU-MIMO-LayersPer-DL-ChannelType | The maximum number of layers that can be multiplexed (can be channel specific). | Outside the scope of 3GPP | +| maxNumber-MIMO-Layers-PDSCH | The maximum number of layers that can be allocated to a UE | 3GPP TS 38.211, sec 7.3.1.3 | +| precodingWeightsType | Support for using precoding weights supplied by the AAL Application, or computed in AAL-LPU [11], or semistatic look tables, or any combination. | Outside the scope of 3GPP | +| bch-PayloadFlag | Full payload (32 bits) or portion of payload originating from higher-layers (24 bits), or either | 3GPP TS 38.212, sec 7.1.1 | +| ... | ... | ... | + +1 + +2 Aali-mgmtm + +3 empty + +### 6.2.2b Summary of Configuration + +A carrier to which the AAL\_DOWNLINK\_High-PHY channel models apply shall be configurable by the application. + +Table 6.2.2b-1 lists a subset of the carrier configurations pertinent to AAL\_DOWNLINK\_High-PHY. + +NOTE: Additional configuration parameters are possible for the AALI implementation. + +**Table 6.2.2b-1: Sample Carrier Configurations pertinent to AAL\_DOWNLINK\_High-PHY** + +| Configuration | Short summary | 3GPP Spec Reference | +|------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| dl-Bandwidth | Carrier bandwidth, for the DL transmission | 3GPP TS 38.104, sec 5.2, 5.3<br>3GPP TS 38.211, sec 4.4.4.2 | +| dl-Frequency | Carrier reference frequency (e.g. Point A, or RF reference frequency), for the DL transmission | 3GPP TS 38.104, sec 5.2, 5.3<br>3GPP TS 38.211, sec 4.4.4.2 | +| dl-GridSize | numerology $\mu$ , for DL transmission; can correspond to 15, 30, 60, 120, 240 kHz. | 3GPP TS 38.211, sec 4.2 | +| dl-CarrierOffset | Offset to carrier or $k_0^\mu$ , per numerology $\mu$ | 3GPP TS 38.331, sec 6.3.2<br>3GPP TS 38.211, sec 5.3.1 | +| num-TX-Ant | Number of baseband antenna ports for DL transmission | Outside the scope of 3GPP | +| prb-SymbRM-Patterns | Semistatic configuration of bitmap-based set of RBs and symbols, to reference for PDSCH rate match purposes | 3GPP TS 38.214, sec 5.1.4.1<br>3GPP TS 38.331, sec 6.3.2 | +| coreset-RM-Patterns | Semistatic CORESET-based set of RBs and symbols, to reference for PDSCH rate match purposes | 3GPP TS 38.214, sec 5.1.4.1<br>3GPP TS 38.331, sec 6.3.2 | +| lte-CRS-RM-Patterns | Semistatic LTE CRS patterns, to reference for PDSCH rate match purposes | 3GPP TS 38.214, sec 5.1.4.1<br>3GPP TS 38.331, sec 6.3.2 | +| beamformingTable | Semistatic configuration of beamforming vectors for DL transmission | Largely outside the scope of 3GPP.<br><br>In some implementations, the beamforming vectors might be related to CSI-RS ports. | +| precodingTable | Semistatic configuration of precoding matrices for DL transmission | Largely outside the scope of 3GPP.<br><br>In some implementations semistatic precoding matrices might be related to PMI reports in 3GPP TS 38.214, sec 5.2.2.2 | +| [Semistatic configuration of DL Channel parameters.] | Alternative semistatic provisioning of some semistatic DL Channel parameters; See the respective Power Offset parameters in the tables in the quoted reference sections for e.g.: | c.f Table 6.2.6.2-3 | + +| | | | +|-------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------| +| | <b>SSB:</b> $N_{ID}^{cell}$ , $L_{max}$ , offsetToPointA, $\mu$ , $\mu_0$ , $k_{SSB}$ , Case, SSB candidates, SSB period, Power offset, beams<br><br>– can be for multiple SSB configurations. | | +| [Power offset configurations] | Alternative semistatic configuration pertaining to semistatic power offset parameters for DL Channel models. See the respective Power offset parameters in the reference sections. | c.f Sections 6.2.3, 6.2.4, 6.2.5 and 6.2.6 | +| [U-plane configuration] | Semistatic configuration for correct routing of OFH packets towards the O-RU. The parameters include, but not limited to:<br><br>- Processing Elements<br>- Configured low-level-tx-end points<br>- Transmit carriers | Sec D.3.8 of ORAN-WG4-MP.0.v007.01 | + +NOTE 1: Additional configuration parameters may be added in future releases to support additional features beyond basic 3GPP Rel-15. + +NOTE 2: The summary description of configuration parameters outside the scope of 3GPP is not meant to restrict the mechanism or data type for such configuration. + +### 6.2.3 PDSCH Channel Model + +Per section 5.1.3.2.7 of the O-RAN AAL GANP document [7] for the PDSCH High PHY Profile, the PDSCH Channel model of the AAL\_DOWNLINK\_High-PHY Profile supports acceleration of PDSCH Data, DM-RS and PT-RS functionalities. + +The set of accelerated functions associated with the processing of PDSCH TB(s) is as follows: + +- TB CRC attachment +- CB segmentation and CRC attachment +- LDPC encoding +- Rate matching +- CB concatenation +- Scrambling +- Modulation +- Layer mapping +- Precoding <sup>1</sup> + +<sup>1</sup> Configurable functional block, depends on implementation and/or system configuration + +- RE mapping +- Power Offset +- IQ compression<sup>1</sup> + +The set of accelerated functions associated with the processing of PDSCH DM-RS is as follows: + +- PDSCH DM-RS sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- Power Offset +- IQ compression<sup>1</sup> + +The set of accelerated functions associated with the processing of PDSCH PT-RS is as follows: + +- Sequence Generation +- Layer Mapping +- Modulation +- Precoding<sup>1</sup> +- RE Mapping +- Power Offset +- IQ compression<sup>1</sup> + +#### 6.2.3.1 PDSCH input for AAL\_DOWNLINK\_High-PHY Profile + +The AAL\_DOWNLINK\_High-PHY profile shall signal PDSCH allocation(s) per slot. The input consists of the TB(s), and the associated parameters for the PDSCH allocation. + +#### 6.2.3.2 PDSCH Parameters + +The following parameters are required to be supported by the AAL implementation when offloading operations. The AAL Application shall supply all relevant parameters; for ease of reading, the parameters are organized per signal type: Data, DM-RS, PT-RS. + +PDSCH Data Parameters + +**Table 6.2.3.2-1: PDSCH Data Parameters** + +| AAL-LPU parameters | Short summary | 3GPP Spec Reference | +|--------------------|---------------|---------------------| +| MAC PDU for TB(s) | | | + +| | | | +|----------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------| +| nrOfCodewords | number of codewords in the PDSCH transmission (CW index $q = 0,1$ )<br><br>In case of single-codeword transmission, $q = 0$ . | 3GPP TS 38.214, sec 5.1.3.2 (max #CW)<br>3GPP TS 38.211, sec 7.3.1.1 (q index) | +| mac-PDU[q] | Initial transmission/non-CBG-based Re-tx: full TB to transmit<br>CBG-based Re-tx: CBs to re-transmit | 3GPP TS 38.214, sec 5.1.3.2 (non-CBG ReTx/initial Tx)<br>3GPP TS 38.214, sec 5.1.7 (CBG-based Tx) | +| tb-Size[q] | Transport block size. Computed at L2. | 3GPP TS 38.214, sec 5.1.3.2 | +| TB CRC | | | +| dl-TB-CRC-CW[q] | Compute CRC once, reuse in case of re-transmission (CBG case: must be appended if last CB is retransmitted).<br><br>NOTE: support for CRC caching is up to implementation and may be subject to capabilities. | 3GPP TS 38.212, sec 7.2.1 | +| CB Segmentation + CRC | | | +| isLastCB-Present [q] | In case of CBG-based Re-tx, and last CBG is re-tx (CBGTI in 38.212), TB CRC is appended to the last CRC in the MAC Payload. Separate per CW<br><br>CB CRC is computed in L1 accelerator from MAC PDU (no special controls needed for initial tx; see CB Concatenation section for handling options in case of CBG Re-tx)<br><br>NOTE: Cached CRC provisioning is up to implementation and may be subject to capabilities. | 3GPP TS 38.214, sec 5.1.3.2<br>3GPP TS 38.212, sec 7.3.1.2.2 | +| LDPC Encoding | | | +| rv-Index[q] | redundancy version, per CW. Determines starting position $k_0$ in the circular buffer. In DCI, or from aggregation, or from first TB. | 3GPP TS 38.212, Table 5.4.2.1-2,<br>3GPP TS 38.214, Table 5.1.2.1-2 | +| targetCodeRate[q] or (mcs-Table and mcs-Index[q]). | targetCodeRate[q]: target code rate (per CW)<br>Explicit, for initial transmission. Implicit from tb-Size and allocation, for retransmissions.<br><br>mcs-Table and mcs-Index[q]: target code rate can be extracted | 3GPP TS 38.212, sec 5.4.2.1<br>3GPP TS 38.214, sec 5.1.3.1 | + +| | | | +|--------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------| +| | from the index (first transmission), or as above for retransmissions. | | +| newData[q] | Signals whether there is a new transmission, or a retransmission (per CW) | 3GPP TS 38.212, sec 7.3.1.2.1/2 | +| ldpc-Baseraph[q] | LDPC base graph to use (can be explicit, or derived from TB size and initial target rate) (per CW) | 3GPP TS 38.212, sec 7.2.2 | +| tb-SizeLBRM-Bytes or nCB | <p>tbSizeLBRM-Bytes: Reference TBS for allocations subject to rateMatching = limitedBufferRM; impacts circular buffer length</p> <p>nCB = circular buffer length, after account for any FBRM/LBRM considerations.</p> | 3GPP TS 38.212, sec 5.4.2.1, 7.2.5 | +| Rate Matching references (determining unavailable REs) | | | +| ssb-PDUs-For RM | Set of SSBs, where PDSCH mapping is not possible. | 3GPP TS 38.214, sec 5.1.4 | +| prbSymRM-Patterns | Bitmap-based set of RBs and symbols not available for allocation | 3GPP TS 38.214, sec 5.1.4.1<br>3GPP TS 38.331, sec 6.3.2 | +| coreset-RM-Patterns | CORESET-based set of RBs and symbols not available for allocation | 3GPP TS 38.214, sec 5.1.4.1<br>3GPP TS 38.331, sec 6.3.2 | +| dcI-Index | <p>Index of a granting DCI; Rate Matching applies around the PDCCH grant index by this number, for the allocation (+ special consideration for AL16 candidates).</p> <p>See the ‘same-index CCE Candidate’ currently part of PDCCH Profile. Alternatively, that field can be signaled as a part of the PDSCH Profile, as it is applicable to PDSCH Rate Matching.</p> | 3GPP TS 38.214, sec 5.1.4.1 | +| lte-CRS-RM-Patterns | <p>LTE-CRS REs not available for allocation (+MBSFN awareness, for LTE-CRS RE mapping to symbols)</p> <p>NOTE: In 3GPP, this is an RRC parameter</p> | 3GPP TS 38.214, sec 5.1.4.2<br>3GPP TS 38.331, sec 6.3.2 | +| csi-RS-For-RM | CSI-RS REs not available for allocation | 3GPP TS 38.214, sec 5.1.4.2<br>3GPP TS 38.331, sec 6.3.2 | +| CB Concatenation | | | + +| | | | | +|-------------------------------------------------|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------| +| isLastCB-Present [q] | | CBG-based Re-tx: presence of last CB requires TB CRC to be re-appended. | 3GPP TS 38.214, sec 5.1.3.2<br>3GPP TS 38.212, sec 7.3.1.2.2 | +| <i>see section on MAC PDU for TB(s)</i> | | CB concatenation is handled in L2, in case of CBG-retx. CB CRC attachment in L1 Accelerator.<br><br>Alternatively, CB concatenation can be handled exclusively in L1 accelerator, based on CBGTI signaling from L2 | see section on MAC PDU for TB(s) | +| Scrambling | | | | +| nID-PDSCH or cInit [q] | | nID-PDSCH: data scrambling identity (PCI by default)<br><br>cInit[q]: scrambling initialization for codeword q. | 3GPP TS 38.211, sec 7.3.1.1<br><br>3GPP TS 38.300, sec 3.1 | +| rnti | | RNTI associated with the PDSCH transmission | 3GPP TS 38.211, sec 7.3.1.1 | +| Modulation | | | | +| qam-ModOrder[q] or (mcs-Table and mcsIndex[q]). | | qam-ModOrder[q]: Signaled via MCS in DCI; also impacts bit interleaving<br><br>mcs-Table and mcs-Index[q]: modulation can be extracted from the MCS table and index. | 3GPP TS 38.214, sec 5.1.3.1<br>3GPP TS 38.212, sec 5.4.2.2 | +| Layer Mapping | | | | +| nrOfLayers | | total number of layers (when > 4, assignment to codewords described in 38.211. | 3GPP TS 38.211, sec 7.3.1.3<br>3GPP TS 38.214, sec 5.1 | +| Precoding | | | | +| <i>See section 6.2.7</i> | | Conceptually similar to FH signaling when precoding for Cat-B. 3GPP leaves DL precoding to implementation.<br>Per layer (which also implies per CW) | | +| RE Mapping | | | | +| Frequency Domain | bwp-Start | Start, w.r.t. CRB, of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PDSCH allocation | 3GPP TS 38.211, sec 7.3.1.6 | +| | bwp-Size | Size of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PDSCH allocation | 3GPP TS 38.211, sec 7.3.1.6 | + +| | | | | +|---------------|-------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------| +| | subcarrierSpacing | subcarrier spacing impacts waveform generation, including centering | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | numDMRS-CDM-GrpsNoData | No PDSCH mapping on DMRS CDM groups marked as having no data. | 3GPP TS 38.214, sec 5.1.3.2<br>3GPP TS 38.212, sec 7.3.1.2.2<br>3GPP TS 38.214, Table 4.1-1 | +| | resourceAlloc | Mapping to VRBs: bitmap-based (type 0) or offset & length (type 1) | 3GPP TS 38.214, sec 5.1.2.2 | +| | rb-Bitmap | <u>type 0</u> : allocation is based on this bitmap. In 3GPP, it is signaled at RB group resolution | 3GPP TS 38.214, sec 5.1.2.2.1<br>3GPP TS 38.212, sec 7.3.1.2.2 | +| | rb-Start | <u>type 1</u> : start of allocation derived from DCI RIV | 3GPP TS 38.214, sec 5.1.2.2.2<br>3GPP TS 38.212, sec 7.3.1.2.2 | +| | rb-Size | <u>type 1</u> : number of contiguously allocated VRBs derived from DCI RIV | 3GPP TS 38.214, sec 5.1.2.2.2<br>3GPP TS 38.212, sec 7.3.1.2.2 | +| | vrB-ToPRB-Mapping | virtual resource blocks are mapped to physical resource blocks: interleaved or non-interleaved | 3GPP TS 38.211, sec 7.3.1.6<br>3GPP TS 38.212, sec 7.3.1.2.1/2 | +| | coreset-Type | RB bundling for VRB mapping depends on CORESET and DCI Type (BWP is assumed consistent with CORESET Type): “DCI 1_0 with SI-RNTI-based CRC in Type0-PDCCH CSS in CORESET0”, or otherwise. | 3GPP TS 38.211, sec 7.3.1.6 | +| Time Domain | startSymbolIndex | Start symbol index, for the allocation | 3GPP TS 38.214, Table 5.1.2.1-1 | +| | nrOfSymbols | Number of symbols, for the allocation | 3GPP TS 38.214, Table 5.1.2.1-1 | +| | cyclicPrefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation.<br><br>NOTE: Applies only to $\mu=2$ . | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | +| Rate Matching | <i>see the rate matching section</i> | Rate Matching determines which (RE x Symbol) resources are / are not available for RE mapping. | 3GPP TS 38.214, sec 5.1.4 | +| Power Offset | | | | +| | <acceleration based on hard-coded values> | Derived based on table 3GPP TS 38.214 table 4.1-1, DMRS Config Type and number of DMRS CDM groups without data | 3GPP TS 38.214, sec 4.1, Table 4.1-1 | + +1 + +2 PDSCH DM-RS Parameters + +1 + +Table 6.2.3.2-2: PDSCH DM-RS Parameters + +| AAL-LPU parameters | | Short summary | 3GPP Spec Reference | +|---------------------------------------------|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------| +| <b>Sequence Generation</b> | | | | +| pdsch-DMRS-ScramblingId or cInitFirstSymbol | | $N_{\text{ID}}$ : scrambling identifier for $n_{\text{SCID}}$<br><br>$c_{\text{init}}(l)$ : scrambling initialization for DMRS symb $l$ . | 3GPP TS 38.211, sec 7.4.1.1.1 | +| n-SCID | | sequence index (from DCI; defaults to 0) | 3GPP TS 38.211, sec 7.4.1.1.1 | +| <b>Modulation</b> | | | | +| <acceleration based on hard-coded values> | | PDSCH DM-RS uses QPSK modulation | 3GPP TS 38.211, sec 7.4.1.1.1 | +| <b>Precoding</b> | | | | +| [see PDSCH data precoding] | | DMRS follows PDSCH-data precoding | | +| <b>RE Mapping</b> | | | | +| Frequency Domain | bwp-Start | see PDSCH data table | 3GPP TS 38.211, section 7.3.1.6 | +| | bwp-Size | see PDSCH data table | 3GPP TS 38.211, section 7.3.1.6 | +| | subcarrierSpacing | see PDSCH data table | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | resourceAlloc | see PDSCH data table | 3GPP TS 38.214, sec 5.1.2.2 | +| | rb-Bitmap | see PDSCH data table | 3GPP TS 38.214, sec 5.1.2.2.1<br>3GPP TS 38.212, sec 7.3.1.2.2 | +| | rb-Start | see PDSCH data table | 3GPP TS 38.214, sec 5.1.2.2.2<br>3GPP TS 38.212, sec 7.3.1.2.2 | +| | rb-Size | see PDSCH data table | 3GPP TS 38.214, sec 5.1.2.2.2<br>3GPP TS 38.212, sec 7.3.1.2.2 | +| | vrb-to-PRB-Mapping | see PDSCH data table | 3GPP TS 38.211, sec 7.3.1.6<br>3GPP TS 38.212, sec 7.3.1.2.1/2 | +| | refPoint | NOTE:<br><br>Reference point for RE mapping depends on CORESET Type and target for grant: <ul style="list-style-type: none"> <li>subcarrier 0 of lowest RB of CORESET0, or</li> <li>subcarrier 0 of CRB0</li> </ul> | 3GPP TS 38.211, sec 7.4.1.1.2 | +| | dmrs-Ports | Bitmap of DMRS ports, for each layer. OC weights applied to DM-RS REs are based on DM-RS CDM group | 3GPP TS 38.211, sec 7.4.1.1.2 | + +| | | | | +|--------------|----------------------|----------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------| +| | | and identifier for each DM-RS port. | | +| | dmrs-ConfigType | DMRS configuration type controls port to CDM group correspondence and frequency density (type 1: 8 ports, type 2: 12 ports) | 3GPP TS 38.211, sec 7.4.1.1.2 | +| Time Domain | dl-DMRS-SymbPos | location of DMRS in slot sufficiently captures the impact of upper layer parameters, e.g., mapping type, additional pos | 3GPP TS 38.211, sec 7.4.1.1.2 and Tables 7.4.1.1.2-3 and 7.4.1.1.2-4 | +| | dmrs-Ports | Bitmap of DMRS ports, for each layer. OC weights applied to DM-RS REs are based on DM-RS CDM group and identifier for each DM-RS port. | 3GPP TS 38.211, sec 7.4.1.1.2 | +| | cyclicPrefix | see PDSCH data table | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | +| Power Offset | | | | +| | powerControOffset-SS | power offset with respect to SSS | 3GPP TS 38.214, sec 5.2.2.3.1<br>3GPP TS 38.214, sec 4.1<br>3GPP TS 38.213, sec 4.1 | + +1 + +2 PDSCH PT-RS Parameters + +3 + +**Table 6.2.3.2-2: PDSCH PR-RS Parameters** + +| AAL-LPU parameters | Short summary | 3GPP Spec Reference | +|-------------------------------------------|-----------------------------------------------------------------------------------------|--------------------------------------------------------------| +| Sequence Generation | | | +| ptrs-PortIndex | DMRS port associated with the PT-RS port according to clause 5.1.6.3 in [6, TS 38.214]. | 3GPP TS 38.211, sec 7.4.1.2.1 | +| Layer Mapping | | | +| ptrs-PortIndex | DMRS port associated with the PT-RS port according to clause 5.1.6.3 in [6, TS 38.214]. | 3GPP TS 38.211, sec 7.4.1.2.2<br>3GPP TS 38.214, sec 5.1.6.3 | +| Modulation | | | +| <acceleration based on hard-coded values> | PDSCH PTRS uses QPSK modulation, like PDSCH DMRS | 3GPP TS 38.211, sec 7.4.1.1.1 | + +| Precoding | | | | +|---------------------------------------|-------------------|---------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------| +| <same as the associated dmrs Port(s)> | | | | +| RE Mapping | | | | +| Frequency Domain | bwp-Start | see PDSCH data table | 3GPP TS 38.211, section 7.3.1.6 | +| | bwp-Size | see PDSCH data table | 3GPP TS 38.211, section 7.3.1.6 | +| | subcarrierSpacing | see PDSCH data table | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | ptrs-FreqDensity | frequency density (includes the case where there is no PT-RS) | 3GPP TS 38.214, sec 5.1.6.3, Table 5.1.6.3-2 | +| | ptrs-RE-Offset | re offset (can depend on DMRS association and RRC signaling of resourceElementOffset) | 3GPP TS 38.211, sec 7.4.1.2.2, table 7.4.1.2.2-1<br>3GPP TS 38.331, sec 6.3.1 | +| | rnti | RNTI associated with the PDSCH transmission | 3GPP TS 38.211, sec 7.4.1.2.2 | +| Time Domain | ptrs-TimeDensity | time density (includes the case where there is no PT-RS) | 3GPP TS 38.214, sec 5.1.6.3 Table 5.1.6.3-1 | +| | dl-DMRS-SymbPos | see PDSCH DMRS table symbols used for DMRS (PT-RS skips over these) | 3GPP TS 38.211, sec 7.4.1.1.2 and Tables 7.4.1.1.2-3 and 7.4.1.1.2-4 | +| | cyclicPrefix | see PDSCH data table | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | +| Power Offset | | | | +| n-EPRE-RatioOf-PDSCH-To-PTRS | | Derived based on table 3GPP TS 38.214 table 4.1-2, epre-Ratio and number of associated DMRS ports | 3GPP TS 38.214, sec 4.1, Table 4.1-2 | + +1 + +### 6.2.4 PDCCH Channel Model + +Per section 5.1.3.2.7 of the O-RAN AAL GANP document [7] for the PDCCH High-PHY Profile, the PDCCH Channel model of the AAL\_DOWNLINK\_High-PHY Profile supports acceleration of PDCCH Data and DM-RS functionality. + +The set of accelerated functions associated with the processing of PDCCH DCIs is as follows: + +- CRC attachment +- Polar encoding +- Rate matching +- Scrambling +- Modulation (QPSK) +- Precoding<sup>1</sup> + +- RE mapping +- IQ compression<sup>1</sup> +- Power Offset + +The set of accelerated functions associated with the processing of PDCCH DM-RS is as follows: + +- Sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +#### 6.2.4.1 PDCCH input for AAL\_DOWNLINK\_High-PHY Profile + +The AAL\_DOWNLINK\_High-PHY profile shall signal PDCCH CORESET allocation(s) per slot. The input data consists of the DCI payloads and the associated parameters for the PDCCH CORESET and DCI mapping. + +#### 6.2.4.2 PDCCH Parameters + +The following parameters are required to be supported by the AALI implementation when offloading operations. The AAL Application shall supply all relevant parameters; for ease of reading, the parameters are organized per signal type: Data, DM-RS. + +PDCCH Data Parameters + +**Table 6.2.4.2-1: PDCCH Data Parameters** + +| AAL-LPU parameters | | Summary | 3GPP Spec Reference | +|---------------------------|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------| +| MAC PDU(s) – DCI payloads | | | | +| num-DCI | | number of DCIs in the CORESET | 3GPP TS 38.213, section 10.1 | +| per-DCI | payload | DCI payload generated by L2 | 3GPP TS 38.212, sec 7.3, 7.3.1 | +| | payload-Size | Transport block size. Computed at L2. | 3GPP TS 38.212, sec 7.3, 7.3.1 | +| PDU CRC | | | | +| per-DCI | n-RNTI-PDCCH-Data | CRC computation detailed in 38.212<br># payload size A from MAC<br># parity size L hardcoded to 24 bits<br># generator polynomial hard-coded to g_{CRC24C}(D)<br># CRC scrambled with RNTI | 3GPP TS 38.212, sec 7.3.2 | +| Polar Encoding | | | | + +| | | | | +|-------------------------------------------|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------| +| aggregationLevel | | <p>Encoding detailed in 38.212:<br/> # input sequence (payload with CRC) has <math>K=A+24</math> bits<br/> # <math>n_{\text{max}}</math> is hardcoded to 9<br/> # <math>I_{\text{IL}}</math> is hardcoded to 1<br/> # <math>n_{\text{PC}}</math> is hardcoded to 0<br/> # <math>n_{\text{PC}}^{\text{wm}}</math> is hardcoded to 0</p> <p>=====</p> <p>N: encoded bit length is a direct function of K (<math>A+24</math>) and E (#no-DMRS PDCCH symbols based on <math>AL * 2</math>) and a set of hardcoded parameters.</p> <p>Interleaving: function of <math>I_{\text{IL}}</math> (hardcoded for PDCCH) and a set of additional hardcoded table and parameters, operates on the payload</p> <p>Encoding: function of <math>n_{\text{PC}}</math> (hardcoded for PDCCH), <math>n_{\text{PC}}^{\text{wm}}</math> (hardcoded for PDCCH), + additional spec hardcoded tables and parameters, operates on the interleaved payload</p> | 3GPP TS 38.212, sec 7.3.3 | +| Rate Matching | | | | +| aggregationLevel | | <p>Rate matching detailed in 38.212<br/> # out size <math>E=2*\text{\#non-DMRS REs}</math> (function of Aggregation Level)<br/> # rate match algorithm uses this E, the size of the original sequence + CRC (K), <math>n_{\text{PC}}</math> (hardcoded to 0) and <math>n_{\text{BIL}}</math> (hardcoded to 0) to operate on the polar-coded payload</p> | 3GPP TS 38.214, sec 7.3.4 | +| Scrambling | | | | +| per-DCI | n-ID-PDCCH-Data or cInit | <p><math>n_{\text{ID}}</math>: data scrambling identity (PCI by default, can be UE-specific)</p> <p><math>c_{\text{init}}</math>: scrambling initialization</p> | 3GPP TS 38.211, sec 7.3.2.3 | +| | n-RNTI-PDCCH-Data | RNTI-based scrambling associated with the DCI transmission (0 for CSS) | 3GPP TS 38.211, sec 7.3.2.3 | +| Modulation | | | | +| <acceleration based on hard-coded values> | | PDCCH uses QPSK modulation | 3GPP TS 38.211, sec 7.3.2.4<br>3GPP TS 38.211, sec 5.1.3 | +| Precoding | | | | + +| | | | | +|------------------|---------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------| +| per-DCI | See section 6.2.7 | Conceptually similar to FH signaling when precoding for Cat-B. 3GPP leaves DL precoding to implementation. | | +| RE Mapping | | | | +| Frequency Domain | coreset-BWP-Start | Start, w.r.t. CRB, of bandwidth part: RBs indexing for the frequency domain allocation is relative to the Bandwidth part for the PDCCH allocation | 3GPP TS 38.211, sec 7.3.2.2<br>3GPP TS 38.331, sec 6.3.2 | +| | coreset-BWP-Size | Size of bandwidth part: RBs indexing for the frequency domain allocation is relative to the Bandwidth part for the PDCCH allocation | 3GPP TS 38.211, section 7.3.1.6 | +| | subcarrierSpacing | subcarrier spacing impacts waveform generation, including centering | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | regBundleSize | Number of REGs in an REG Bundle | 3GPP TS 38.211, sec 7.3.2.2<br>3GPP TS 38.331, sec 6.3.2 | +| | interleaverSize | Interleaver size | 3GPP TS 38.214, sec 5.1.2.2.2<br>3GPP TS 38.212, sec 7.3.1.2.2 | +| | cce-REG-MappingType | Mapping of Control Channel Elements (CCE) to Resource Element Groups (REG) | 3GPP TS 38.211, sec 7.3.2.2<br>3GPP TS 38.211, sec 7.4.1.3.2<br>3GPP TS 38.331, sec 6.3.2 | +| | freqDomainResource | Bitmap signaling the frequency domain resources for the CORESET. Each bit corresponds a group of 6 RBs, with grouping starting from the first RB group in the BWP. Validity and bit mapping per the RRC parameter frequencyDomainResources in 38.331<br><br>This parameter applies to both regular CORESETs, as well as CORESET0. For the interpretation regarding CORESET0, see section 13 of 38.213. | 3GPP TS 38.211, sec. 7.3.2.2<br>3GPP TS 38.331, sec 6.3.2<br>3GPP TS 38.213, sec 13 | +| | shiftIndex | offset used in the computation of the interleaver function for CCE-to-REG mapping | 3GPP TS 38.211, sec 7.3.2.2 | +| | precoderGranularity | Precoder granularity in frequency domain (for data, this is strictly not needed, as it will be accounted for in the precoding) | 3GPP TS 38.211, sec 7.3.2.2<br>3GPP TS 38.211, sec 7.4.1.3.2 | +| FD per DCI | cce-Index | cce Index for sending the DCI | 3GPP TS 38.213, sec 10.1 | + +| | | | | +|------------------------------------------------------|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------| +| | collocated-AL16-Candidate | indicates presence of an AL-16 candidate existing at the same CCE Index, for PDSCH rate matching purposes<br><br>NOTE: This information is relevant to PDSCH rate matching, and could be signaled in PDSCH for rate matching purposes, instead. See the Rate Matching section of the PDSCH Profile | 3GPP TS 38.214, sec 5.1.4.1 | +| | aggregationLevel | aggregation level for the DCI | 3GPP TS 38.211, sec 7.3.2.1<br>3GPP TS 38.213, sec 10.1 | +| Time Domain | startSymbolIndex | Start symbol index, for the allocation | 3GPP TS 38.211, sec. 7.3.2.2 | +| | durationSymbols | Number of symbols, for the allocation | 3GPP TS 38.211, sec. 7.3.2.2 | +| | cyclicPrefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | +| Power Offset | | | | +| [Power offset w.r.t. SSS] can be hardcoded, for MVP. | | see PDCCH DMRS table. Can be set to the same value. | 3GPP TS 38.214, sec 5.2.2.3.1<br>3GPP TS 38.214, sec 4.1<br>3GPP TS 38.213, sec 4.1 | + +1 + +2 PDCCH DM-RS Parameters + +3 + +**Table 6.2.4.2-2: PDCCH DM-RS Parameters** + +| AAL-LPU parameters | | Summary | 3GPP Spec Reference | +|-------------------------------------------|----------------------------|------------------------------------------------------------------------------------|---------------------------------| +| | | | | +| per DCI | n-ID-PDCCH-Data or cInit | N_{ID}: scrambling identifier<br><br>c_{init}: scrambling initialization for DMRS. | 3GPP TS 38.211, sec 7.4.1.3.1 | +| Modulation | | | | +| <acceleration based on hard-coded values> | | PDCCH DM-RS uses QPSK modulation | 3GPP TS 38.211, sec 7.4.1.3.1 | +| Precoding | | | | +| per DCI | [see PDCCH data precoding] | DMRS follows PDCCH-data precoding | | +| RE Mapping | | | | +| Frequency Domain | coreset-BWP-Start | see PDCCH data table | 3GPP TS 38.211, section 7.3.2.2 | +| | coreset-BWP-Size | see PDCCH data table | 3GPP TS 38.211, section 7.3.2.2 | + +| | | | | +|----------------------|---------------------|-----------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------| +| | subcarrierSpacing | see PDCCH data table | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | coreset-Type | reference point for RE mapping physical resources of DMRS depends on CORESET type (#0 or not) | 3GPP TS 38.211, sec 7.4.1.3.2 | +| | precoderGranularity | Precoder granularity in frequency domain (impacts whether DMRS should be generated for all RBs or only allocated RBs) | 3GPP TS 38.211, sec 7.3.2.2<br>3GPP TS 38.211, sec 7.4.1.3.2 | +| Freq Domain per DCI | cce-Index | see PDCCH data table | 3GPP TS 38.213, sec 10.1 | +| | aggregationLevel | see PDCCH data table | 3GPP TS 38.211, sec 7.3.2.1<br>3GPP TS 38.213, sec 10.1 | +| Time Domain | startSymbolIndex | see PDCCH data table | 3GPP TS 38.211, sec. 7.3.2.2 | +| | durationSymbols | see PDCCH data table | 3GPP TS 38.211, sec. 7.3.2.2 | +| | cyclicPrefix | see PDCCH data table | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | +| Power Offset | | | | +| powerControlOffsetSS | | power offset with respect to SSS | 3GPP TS 38.214, sec 5.2.2.3.1<br>3GPP TS 38.214, sec 4.1<br>3GPP TS 38.213, sec 4.1 | + +### 6.2.5 CSI-RS Channel Model + +Per section 5.1.3.2.7 of the O-RAN AAL GAnP document [7] for the CSI-RS High PHY Profile, the CSI-RS Channel model of the AAL\_DOWNLINK\_High-PHY Profile supports acceleration of CSI-RS functionality. + +The set of accelerated functions associated with the processing of CSI-RS is as follows: + +- CSI-RS sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> +- Power Offset + +#### 6.2.5.1 CSI-RS input for AAL\_DOWNLINK\_High-PHY Profile + +The AAL\_DOWNLINK\_High-PHY profile shall signal CSI-RS Resource(s) per slot. The input consists of the CSI-RS resource parameters. + +CSI-RS Parameters + +1 The following parameters are required to be supported by the AALI implementation when offloading operations. The +2 AAL Application shall supply all relevant parameters. + +##### 3 6.2.5.2 CSI-RS Parameters + +4 **Table 6.2.5.2: CSI-RS Parameters** + +| AAL-LPU Parameters | | Summary | 3GPP Spec Reference | +|-------------------------------------------|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------| +| Sequence Generation | | | | +| scrambId or cInitFirstSymbol | | n_{ID}: scrambling id<br><br>c_{init}[l]: scrambling initialization for symb [l] | 3GPP TS 38.211, sec 7.4.1.5.2 | +| Modulation | | | | +| <acceleration based on hard-coded values> | | CSI-RS uses QPSK modulation | 3GPP TS 38.211, sec 7.4.1.5.2 | +| Precoding | | | | +| See section 6.2.7 | | Conceptually similar to FH signaling when precoding for Cat-B. 3GPP leaves DL precoding to implementation. | | +| RE Mapping | | | | +| Frequency Domain | subcarrierSpacing | subcarrier spacing impacts waveform generation, including centering | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | startingRB | PRB where this CSI resource starts in relation to CRB#0 | 3GPP TS 38.331, sec 6.3.2 | +| | nrOfRBs | Number of PRBs across which this CSI resource spans. | 3GPP TS 38.331, sec 6.3.2 | +| | freqDomain | Bitmap defining the frequencyDomainAllocation, with interpretation subject to the Row selection for table 7.4.1.5.3-1 | 3GPP TS 38.331, sec 6.3.2<br>3GPP TS 38.211, sec 7.4.1.5.3 | +| | row | row indicating the CSI-RS location in table 7.4.1.5.3-1. Can be used to derive; <ul style="list-style-type: none"> <li>density <math>\rho</math> (see also Frequency Density)</li> <li>cdmType</li> <li>ports</li> <li><math>\bar{k}</math> in the <math>(\bar{k}, \bar{l})</math>-tuple</li> </ul> | 3GPP TS 38.331, sec 6.3.2<br><br>3GPP TS 38.211, sec 7.4.1.5.3 | +| | freqDensity | Indicates whether even or odd PRBs are occupied by CSI-RS. | 3GPP TS 38.331, sec 6.3.2<br><br>3GPP TS 38.211, sec 7.4.1.5.3 | + +| | | | | +|---------------------|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------| +| | | Applicable when density = dot5 (0.5) | | +| Time Domain | row | row indicating the CSI-RS location in table 7.4.1.5.3-1. Can be used to derive; <ul style="list-style-type: none"> <li><math>\bar{l}</math> in the <math>(\bar{k}, \bar{l})</math>-tuple</li> </ul> | 3GPP TS 38.331, sec 6.3.2<br>3GPP TS 38.211, sec 7.4.1.5.3 | +| | symbL0 | value of $l_0$ for the interpretation of table 7.4.1.5.3-1. Signaled by RRC parameter firstOFDMSymbolInTimeDomain | 3GPP TS 38.331, sec 6.3.2<br>3GPP TS 38.211, sec 7.4.1.5.3 | +| | symbL1 | value of $l_1$ for the interpretation of table 7.4.1.5.3-1. Signaled by RRC parameter firstOFDMSymbolInTimeDomain2 | 3GPP TS 38.331, sec 6.3.2<br>3GPP TS 38.211, sec 7.4.1.5.3 | +| | cyclicPrefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | +| <b>Power Offset</b> | | | | +| | powerControlOffsetSS | power offset with respect to SSS | 3GPP TS 38.214, sec 5.2.2.3.1 | + +### 6.2.6 SSB Model + +Per section 5.1.3.2.7 of the O-RAN AAL GAnP document [7] for the PBCH High-PHY Profile, the SSB Channel model of the AAL\_DOWNLINK\_High-PHY Profile supports acceleration of PSS+SSS and PBCH Data and PBCH DM-RS functionality. + +The set of accelerated functions associated with the processing of PSS+SSS is as follows: + +- Sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> +- Power Offset + +The set of accelerated functions associated with the processing of PBCH Data is as follows: + +- PBCH payload generation +- Scrambling +- TB CRC attachment +- Polar encoding +- Rate matching + +- Data scrambling +- Modulation (QPSK) +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> + +The set of accelerated functions associated with the processing of PBCH DM-RS is as follows: + +- Sequence generation +- Modulation +- Precoding<sup>1</sup> +- RE mapping +- IQ compression<sup>1</sup> +- Power Offset + +#### 6.2.6.1 SSB input for AAL\_DOWNLINK\_High-PHY Profile + +The AAL\_DOWNLINK\_High-PHY profile shall signal SSB allocation(s), per slot (up to two per slot and SSB configuration, at the SSB slot numerology). The input consists of the PBCH payload and the associated SSB resource allocation parameters. + +#### 6.2.6.2 SSB Parameters + +The following parameters are required to be supported by the AAL implementation when offloading operations. The AAL Application shall supply all relevant parameters; for ease of reading, the parameters are organized per signal type: PBCH Data, PBCH DM-RS, PSS&SSS. + +PBCH Data Parameters + +**Table 6.2.6.2-1: PBCH Data Parameters** + +| AAL-LPU Parameters | Summary | 3GPP Spec Reference | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------| +| MAC PDU(s) | | | +| bch-Payload | PBCH payload (generated by L2, or in AAL-LPU) - may be the full payload (32 bits) or only the portion supplied from higher layers (24 bits). | 3GPP TS 38.212, sec 7.1, 7.1.1 | +| Payload Scrambling | | | +| physCellId or cInit | <p><math>N_{\text{ID}}^{\text{cell}}</math>: Physical layer cell ID, as defined in as defined in 3GPP TS 38.211, section 7.4.2.1</p> <p><math>c_{\text{init}}</math>: scrambling initialization</p> | 3GPP TS 38.211, sec 7.4.1.4.1, 7.1.2 | + +| | | | +|-------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------| +| l-Max | Maximum number of candidate SS/PBCH blocks in a half frame | 3GPP TS 38.211, sec 7.3.3.1, 7.1.2 | +| CRC | | | +| <acceleration based on hard-coded values> | <p>CRC computation detailed in 38.212:</p> <p># (scrambled) payload size A from MAC: <math>24+8=32</math> bits (Rel-15,16)</p> <p># parity size L hardcoded to 24 bits</p> <p># generator polynomial hardcoded to <math>g_{\{CRC24C\}}(D)</math></p> | 3GPP TS 38.212, sec 7.1.3 | +| Polar Coding | | | +| <acceleration based on hard-coded values> | <p>Encoding detailed in 38.212:</p> <p># input sequence (scrambled payload with CRC) has <math>K = B = 32 + 24 = 56</math> bits (result of adding up two hardcoded numbers)</p> <p># <math>n_{\{max\}}</math> is hardcoded to 9</p> <p># <math>I_{\{IL\}}</math> is hardcoded to 1</p> <p># <math>n_{\{PC\}}</math> is hardcoded to 0</p> <p># <math>n_{\{PC\}}^{\{wm\}}</math> is hardcoded to 0</p> <p>=====</p> <p>N: encoded bit length is a direct function of K (56) and E (rate match output 864, spelled out in spec) and a set of hard-coded parameters = 512</p> <p>Interleaving: function of <math>I_{\{IL\}}</math> (hardcoded for PBCH) and a set of additional hardcoded table and parameters, operates on the payload</p> <p>Encoding: function of <math>n_{\{PC\}}</math> (hardcoded for PBCH), <math>n_{\{PC\}}^{\{wm\}}</math> (hardcoded for PBCH), + additional spec hard-coded tables and parameters, operates on the interleaved payload</p> | 3GPP TS 38.212, sec 7.1.4 | +| Rate Matching | | | + +| <acceleration based on hard-coded values> | | Rate matching detailed in 38.212<br># out size $E = 864$ , explicit in the spec, but can be derived as<br>(#non-DMRS REs * 2)<br># rate match algorithm uses this E, the size of the original sequence + CRC ( $K = 56$ ),<br>$n_{PC}$ (hardcoded to 0) and<br>$n_{BIL}$ (hardcoded to 0) to operate on the polar-coded payload | 3GPP TS 38.212, sec 7.1.5 | +|-------------------------------------------|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------| +| Scrambling | | | | +| l-Max | | Maximum number of candidate SS/PBCH blocks in a half frame | 3GPP TS 38.211, sec 7.3.3.1 | +| ssb-BlockIndex | | candidate SS/PBCH block index | 3GPP TS 38.211, sec 7.3.3.1 | +| Modulation | | | | +| <acceleration based on hard-coded values> | | PBCH data uses QPSK modulation | 3GPP TS 38.211, sec 7.3.3.2<br>3GPP TS 38.211, sec 5.1.3 | +| Precoding | | | | +| <i>See section 6.2.7</i> | | Conceptually similar to FH signaling when precoding for Cat-B. 3GPP leaves DL precoding to implementation. | | +| RE Mapping | | | | +| Frequency Domain | ssb-OffsetToPointA | Frequency offset between point A and the lowest subcarrier of the lowest resource block, which has the subcarrier spacing provided by the higher-layer parameter subCarrierSpacingCommon and overlaps with the SS/PBCH block" | 3GPP TS 38.211, sec 4.4.4.2 | +| | subcarrierSpacing | subcarrier spacing impacts waveform generation, including centering | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | ssb-SubcarrierOffset | subcarrier offset | 3GPP TS 38.211, sec 7.4.3.1 | +| Time Domain | case | Case determines first symbol mapping | 3GPP TS 38.213, sec 4.1 | +| | ssb-BlockIndex | Used to derive the SSB index in slot | 3GPP TS 38.213, sec 4.1 | +| Power Offset | | | | +| <acceleration based on hard-coded values> | | The UE assumes that SSS, PBCH DM-RS, and PBCH data have same EPRE | 3GPP TS 38.213, sec 4.1 | + +##### PBCH DM-RS Parameters + +**Table 6.2.6.2-2: PBCH DM-RS Parameters** + +| AAL-LPU Parameters | | Summary | 3GPP Spec Reference | +|-------------------------------------------|----------------------|--------------------------------------------------------------------------------------|----------------------------------------| +| Sequence Generation | | | | +| physCellId | | Physical cell ID | 3GPP TS 38.211, sec 7.4.1.4.1, 7.4.2.1 | +| l-Max | | Maximum number of candidate SS/PBCH blocks in a half frame | 3GPP TS 38.211, sec 7.4.1.4.1 | +| i-SSB | | candidate SSB SS/PBCH block index; can also be derived from l-Max and ssb-BlockIndex | 3GPP TS 38.211, sec 7.4.1.4.1 | +| Modulation | | | | +| <acceleration based on hard-coded values> | | PBCH DM-RS uses QPSK modulation | 3GPP TS 38.211, sec 7.4.1.4.1 | +| Precoding | | | | +| [see PBCH data precoding] | | DMRS follows PDCCH-data precoding | | +| RE Mapping | | | | +| Frequency Domain | offsetToPointA | see PBCH data | 3GPP TS 38.211, sec 4.4.4.2 | +| | subcarrierSpacing | see PBCH data | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | ssb-SubcarrierOffset | see PBCH data | 3GPP TS 38.211, sec 7.4.3.1 | +| Time Domain | case | see PBCH data | 3GPP TS 38.213, sec 4.1 | +| | ssb-BlockIndex | see PBCH data | 3GPP TS 38.213, sec 4.1 | +| Power Offset | | | | +| <acceleration based on hard-coded values> | | The UE assumes that SSS, PBCH DM-RS, and PBCH data have same EPRE | 3GPP TS 38.213, sec 4.1 | + +##### PSS & SSS Parameters + +**Table 6.2.6.2-3: PSS & SSS Parameters** + +| AAL-LPU Parameters | | Summary | 3GPP Spec Reference | +|---------------------|--|---------|---------------------| +| Sequence Generation | | | | + +| | | | | +|-------------------------------------------|----------------------|------------------------------------------------------------------------------------------------------------|---------------------------------------------------| +| physCellId | | Physical cell ID - used to derive N_ID(1) for SSS and N_ID(2) for PSS | 3GPP TS 38.211, sec 7.4.2.1, 7.4.2.2.1, 7.4.2.3.1 | +| Modulation | | | | +| <acceleration based on hard-coded values> | | PSS and SSS use BPSK modulation | 3GPP TS 38.211, sec 7.4.2.2.1, 7.4.2.3.1 | +| Precoding | | | | +| See section 6.2.7 | | Conceptually similar to FH signaling when precoding for Cat-B. 3GPP leaves DL precoding to implementation. | | +| RE Mapping | | | | +| Freq Domain | offsetToPointA | see PBCH data tab | 3GPP TS 38.211, sec 4.4.4.2 | +| | subcarrierSpacing | see PBCH data tab | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | ssb-SubcarrierOffset | see PBCH data tab | 3GPP TS 38.211, sec 7.4.3.1 | +| Time Domain | case | see PBCH data tab | 3GPP TS 38.213, sec 4.1 | +| | ssb-BlockIndex | see PBCH data tab | 3GPP TS 38.213, sec 4.1 | +| Power Offset | | | | +| beta-PSS | | PSS EPRE to SSS EPRE in an SSB | 3GPP TS 38.213, sec 4.1 | + +### 6.2.7 Beamforming + +In this release, the AAL\_DOWNLINK\_High-PHY profile supports the following beamforming methods available for OFH signaling: + +- Predefined-Beam Beamforming, as defined in section 10.4.2.1 of [8]; +- Weight-based Dynamic Beamforming, as defined in section 10.4.2.2 of [8]; +- Attribute-Based Dynamic Beamforming, as defined in section 10.4.3 of [8]; +- Channel-Information-Based Beamforming, as defined in section 10.4.4 of [8]. + +#### 6.2.7.1 Predefined-Beam Beamforming + +The AALI shall support the AAL Application signaling of the following parameters, as needed for AAL-LPU-signaling of beamId in C-Plane Section Types 1, 3 [8]: + +- frequency-domain beam indices +- time-domain-domain beam indices +- a mixture of the two (“hybrid beamforming”). + +#### 6.2.7.2 Weight-based Dynamic Beamforming + +The AALI shall support the AAL Application signaling of the following parameters, as needed for AAL-LPU-signaling of beamforming weight vectors of (bfwI, bfwQ) in C-Plane Extensions 1, 11, 19 [8]: + +**Table 6.2.7.2-1: Weight-based Dynamic Beamforming Parameters for Downlink** + +| AAL-LPU Parameters | Summary | AAL-LPU Role | +|----------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| AAL-LPU → AAL Application | | | +| Channel Estimation Abstraction | A representation of SRS-based channel observations, as documented in the SRS channel model in section 6.3.5.2, e.g. for usage antennaSwitch | Signals an abstraction of the Channel Estimation to the AAL Application | +| AAL Application → AAL-LPU | | | +| rnti[*] | Selected UEs for scheduling (for an illustration refer to the L users referenced in Appendix J.4 of [8]) | Compute precoding weights for the selected UEs and layers, e.g. based on the reported Channel Estimation and its Abstraction (if beamforming weights are not provided by the AAL Application). | +| chosenLayers[*] | Per UE: selected Layers for scheduling (for an illustration refer to the K layers referenced in Appendix J.4 of [8]) | | +| Beamforming weights, per UE [optional] | Beamforming weights for the layers of the selected UEs, where beamforming weights may be specified explicitly or may be sent to AAL-LPU as handle to AAL-LPU [11] contexts that uniquely specify the beamforming weights to apply. | Signal to O-RU beamforming vectors of weights (bfwI, bfwQ) over C-Plane for the AAL Application-selected UEs and layers.<br><br>Alternatively, the beamforming weights may be consumed in AAL-LPU itself, e.g. Cat-A, when precoding is applied in the O-DU. | + +#### 6.2.7.3 Attribute-Based Dynamic Beamforming + +The AALI shall support the AAL Application signaling of the following parameters, as needed for AAL-LPU-signaling of beamforming attributes (bfAzPt, bfZePt, bfAz3dd, bfZe3dd, bfAzSl, bfZeSl) in C-Plane Extensions 2 [8]: + +- Zenith main and 3dB angles +- Azimuth main and 3dB angles +- Sidelobe Angles + +#### 6.2.7.4 Channel-Information-Based Beamforming + +The AALI shall support the AAL Application signaling of the following parameters, as needed for AAL\_DOWNLINK\_High-PHYprofile signaling of channel estimate vectors of (ciIsample, ciQsample) in C-Plane Section 6 [8]: + +**Table 6.2.7.4-1: Channel-Information-Based Beamforming Parameters for Downlink** + +| AAL-LPU Parameters | Summary | AAL-LPU Role | +|----------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------| +| AAL-LPU → AAL Application | | | +| [Channel Estimation Abstraction] | A representation of SRS-based channel observations, as documented in the SRS channel model in section 6.3.5.2, e.g. for usage antennaSwitch | Signals an abstraction of the Channel Estimation to the AAL Application | +| AAL Application → AAL-LPU | | | +| mti[*] | Selected UEs for scheduling (for an illustration refer to the L users referenced in Appendix J.4 of [8]) | Signal to O-RU the Channel Estimates for the AAL Application-selected UEs and layers | +| chosenLayers[*] | Per UE: selected Layers for scheduling (for an illustration refer to the K layers referenced in Appendix J.4 of [8]) | | + +## 6.3 O-DU AAL\_UPLINK\_High-PHY Profile Specification + +This profile provides acceleration functionality for the following channels and signals: + +- PUSCH (including Data, DM-RS and PT-RS) +- PUCCH (Data) – Format 0 +- PUCCH (including Data and DM-RS) – Format 1 +- PUCCH (including Data and DM-RS) – Formats 2, 3, 4 +- SRS +- PRACH + +This section presents parametrization for each of these channels and signals, and pertinent carrier configuration. + +### 6.3.1 Profile Operation + +The AAL\_UPLINK\_High-PHY Profile interface shall work on a slot basis. An operation can be performed one slot at a time, where the slot, numerology and SFN are signaled for the API. + +The output data is specific to each uplink channel composing the profile. + +The input data consists of: + +- a set of AAL Application-supplied parameters for each of the modelled uplink channels +- a set of U-Plane OFH packets. + +For the OFH packets, the AAL-LPU interfaces directly with the OFH and is responsible for handling its exchange of information with OFH. + +As much as possible, parameter redundancy should be avoided. Where this is not possible, the AAL-LPU can assume that redundant parameters are consistent. + +### 6.3.2 Summary of Capabilities + +The AAL\_UPLINK\_High-PHY Profile capabilities shall be reported to the application. + +Table 6.3.2-1 lists a subset of the AAL\_UPLINK\_High-PHY profile capabilities that should be reported to the application with respect the acceleration of the various channel functionalities and interaction. + +NOTE: Additional capabilities can also be reported by the AALI implementation. + +**Table 6.3.2-1: Sample AAL\_UPLINK\_High-PHY Profile Capabilities** + +| Capability | Short summary | 3GPP Spec Reference | +|-------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------| +| 3gpp-Release | Rel-15, Rel-16, ... | <a href="https://www.3gpp.org/specifications/work-plan">https://www.3gpp.org/specifications/work-plan</a> | +| max-PUSCH-TB-PerSlot | Number of PUSCH TBs per slot | Outside the scope of 3GPP | +| cyclicPrefix | Normal or Extended | 3GPP TS 38.211, sec 4.2 | +| subcarrierSpacing-UL | 15, 30, 60, 120, 240 kHz; can be channel-specific. | 3GPP TS 38.211, sec 4.2 | +| supportedBandwidth-UL | 5, 10, 15, ... MHz | 3GPP TS 38.104, sec 5.3 | +| uci-MUX-UL-SCH-in-PUSCH | Supported or not | 3GPP TS 38.212, sec 6.3.2 | +| pusch-FrequencyHopping | Supported or not | 3GPP TS 38.214, sec 6.3 | +| pusch-DMRS-ConfigTypes | 1 or 2 or both | 3GPP TS 38.211, sec 6.4.1.1.3 | +| pusch-DMRS-MaxLen | 1 or 2 | 3GPP TS 38.211, sec 6.4.1.1.3 | +| pusch-MappingType | A or B or both | 3GPP TS 38.211, sec 6.4.1.1.3 | +| dfts-OFDM | Supported or not | 3GPP TS 38.211, sec 6.3.1.4 | +| pusch-CBG | Supported or not | 3GPP TS 38.212, sec 5.4.2.1, 7.3.1.1.2 | +| pusch-Max-PTRS | Maximum number of UL PTRS | 3GPP TS 38.211, sec 6.4.1.2 | +| pusch-AggregationFactor | 1-8 or not supported | 3GPP TS 38.214, sec 6.1.2.1 | +| pusch-LBRM-Support | Supported or not | 3GPP TS 38.212, sec 5.4.2.1 | +| pucch-Formats | Bitmap indicating the support for Formats 0, 1, 2, 3 or 4 | 3GPP TS 38.211, sec 6.3.2 | +| pucch-GroupAndSequenceHopping | Group, sequence or neither | 3GPP TS 38.211, sec 6.3.2.2 | +| max-PUCCH-PerSlot | Max number of PUCCH Resources per slot | Outside the scope of 3GPP | +| pucch-Aggregation | Supported or not (formats 1, 3, 4) | | +| supported-SRS-Usage | beamManagement, codebook, nonCodebook, antennaSwitching, including any combination. If none of the supported reports (see “SRS report type support”) requires usage | 3GPP TS 38.214, sec 6.2.1 | + +| | | | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------| +| | awareness, this usage support may be omitted or set to all usage types. | | +| allowed-SRS-reportsPerUsage | e.g. SVD (singular value decomposition), or H (raw channel) report or SINR, or 2D-DFT basis, or other reports, subsampled in frequency domain. | Sec 0 | +| dft-Size-Azimuth and dft-Size-Elevation | <p>DFT size and oversampling factor in azimuth and in elevation (only applicable when SRS report type 2D-DFT basis is supported).</p> <p>The DFT size in azimuth should equal the product of the number of antenna elements in azimuth and the azimuth oversampling factor.</p> <p>The DFT size in elevation should equal the product of the number of antenna elements in elevation and the elevation oversampling factor.</p> | Outside the scope of 3GPP | +| maxNumStrongestBeamsToReport | Parameter K_DFT_beams defined as the number of strongest beams per SRS basis vector for SRS report type 2D-DFT basis (only applicable when SRS report type 2D-DFT basis is supported). | Outside the scope of 3GPP | +| min-RB-resolutionFor-SRS | RB resolution at which the SRS reports may be subsampled | Outside the scope of 3GPP | +| max-SRS-ChannelReportsPerSlot | Maximum number of SRS reports per slot | Outside the scope of 3GPP | +| max-SRS-TX-AntennaPortsPerUE | Maximum number of ports to sample per UE | Partly outside the scope of 3GPP<br>3GPP TS 38.211, sec 6.4.1.4.1 | +| <p>SRS Configurations:</p> <ul style="list-style-type: none"> <li>- maxNumConsecutive-SRS-Slots</li> <li>- srs-FrequencyHopping</li> <li>- max--SRS-CombSize</li> <li>- maxNumSRS-CyclicShifts</li> </ul> | <p>Capabilities regarding SRS configurations:</p> <ul style="list-style-type: none"> <li>• Support for consecutive SRS symbols</li> <li>• SRS frequency hopping</li> <li>• Comb Size</li> <li>• Cyclic shifts</li> </ul> | 3GPP TS 38.211, sec 6.4.1.4 | +| <p>SRS distribution:</p> <ul style="list-style-type: none"> <li>- maxDutyCycleInPercentage</li> <li>- srs-SymbolsBitmap</li> <li>- maxNumSRS-SymbPerSlot</li> </ul> | <p>Capabilities regarding SRS occurrence in time:</p> <ul style="list-style-type: none"> <li>• Duty Cycle: Maximum proportion of SRS-bearing slots in an SRS period.</li> <li>• Bitmap of symbol locations per slot</li> </ul> | <p>3GPP TS 38.211, sec 6.4.1.4</p> <p>Partly outside 3GPP Scope</p> | + +| | | | +|---------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------| +| | <ul style="list-style-type: none"> <li>Symbols per slot</li> </ul> <p>This capability is agnostic to SRS trigger type (e.g. periodic / semi-persistent / aperiodic).</p> | | +| prach-LongFormats<br>prach-ShortFormats | 0-3, A1-3, B1-4, C0-1 | 3GPP TS 38.211, sec 6.3.3 | +| prach-RestrictedSets | Type A, B, none | 3GPP TS 38.211, sec 6.3.3 | +| max-PRACH-FD-OccasionsPerSlot | Per configuration | 3GPP TS 38.211, sec 6.3.3.2 | +| maxNum-PRACH-Configurations | Max number of PRACH configurations | 3GPP TS 38.331, 6.3.2 | +| maxNum-TD-FD-PRACH-OccasionsPerSlot | Max number of Time and Frequency domain ROs per slot, across all configurations | Outside the scope of 3GPP | +| prach-RootProcessingRate | Number of roots that can be processed per unit of time. Can be per preamble format | Outside the scope of 3GPP | +| prach-OccasionsQueueSize | The maximum queue size for processing Rach Occasions | Outside the scope of 3GPP | +| maxNum-UCI-Maps | Limitations regarding to the storage of UCI Part1 → Part2 maps: maximum number of maps | Outside the scope of 3GPP | +| maxNumCarriersBWLayersProduct-UL | Support for forming joint precoders across bandwidth, and across baseband antenna ports. Includes the option of “no support”. | Outside the scope of 3GPP | +| maxNum-MU-MIMO-LayersPer-UL-ChannelType | The maximum number of layers that can be multiplexed (can be channel specific) | Outside the scope of 3GPP | +| max-MIMO-LayersNon-CB-PUSCH<br>max-MIMO-Layers-CB-PUSCH | The maximum number of layers that can be allocated to a UE, per MIMO scheduling type | 3GPP TS 38.211, sec 6.3.1.3 | +| ... | ... | ... | + +1 + +### 6.3.2b Summary of Configuration + +A carrier to which the AAL\_UPLINK\_High-PHY channel models apply shall be configurable by the application. + +Table 6.3.2b-1 lists a subset of the carrier configurations pertinent to AAL\_UPLINK\_High-PHY. + +NOTE: Additional configuration parameters are possible for the AALI implementation. + +**Table 6.3.2b-1: Sample Carrier Configurations pertinent to AAL\_UPLINK\_High-PHY** + +| Configuration | Short summary | 3GPP Spec Reference | +|---------------|---------------|---------------------| +|---------------|---------------|---------------------| + +| | | | +|-----------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------| +| ul-Bandwidth | Carrier bandwidth for the UL reception | 3GPP TS 38.104, sec 5.2, 5.3<br>3GPP TS 38.211, sec 4.4.4.2 | +| ul-Frequency | Carrier reference frequency (e.g. Point A, or RF reference frequency), for the UL reception | 3GPP TS 38.104, sec 5.2, 5.3<br>3GPP TS 38.211, sec 4.4.4.2 | +| ul-GridSize | numerology $\mu$ , for UL reception (except PRACH); can correspond to 15, 30, 60, 120 kHz. | 3GPP TS 38.211, sec 4.2 | +| ul-CarrierOffset | Offset to carrier or $k_0^\mu$ , per numerology $\mu$ | 3GPP TS 38.331, sec 6.3.2<br>3GPP TS 38.211, sec 5.3.1 | +| max-RX-Antennas | Number of baseband antenna ports for UL reception | Outside the scope of 3GPP | +| shift7dot5kHz | Indicates whether there is 7.5 kHz shift or not. | 3GPP TS 38.331, sec 6.3.2 | +| uci-Configuration | Semistatic maps for to reference in assisting L1 to computed the actual size of CSI part 2 | 3GPP TS 38.213, sec 9.3 | +| rssi-MeasurementSupport<br>rsrp-MeasurementSupport | Selection of power metrics (e.g. absolute, relative) and scale (dB, linear) | Partly outside the scope of 3GPP. Some of the units are defined in 3GPP TS 38.133, e.g. for RSSI and RSRP | +| beamformingTable | Semistatic configuration beamforming vectors for UL reception | Outside the scope of 3GPP | +| [Semistatic configuration of UL Channel Model parameters] | Alternative semistatic provisioning of some semistatic UL Channel Model parameters, e.g. see the respective PRACH parameters in the PRACH Channel Model Section 6.3.6.2:<br><br><b>PRACH:</b> restrictedSetConfig, $N_{preamble}^{total}$ , $N_{cs}$ , $M$ , $k_1$ , $\mu_{PUSCH}$ , $\mu_{PRACH}$ , $\bar{k}$ , prachStartSymbol, prachFormat, $N_t^{RA,slot}$ , preambleStartIndex | c.f Table 6.3.6.2-1 | +| [U-plane configuration] | Semistatic configuration for correct routing of OFH packets towards the O-RU. The parameters include, but not limited to:<br><br>- Processing Elements<br><br>- Configured low-level-rx-end points<br><br>- Receive carriers | Sec D.3.8 of ORAN-WG4-MP.0.v007.01 | + +NOTE 1: Additional configuration parameters may be added in future releases to support additional features beyond basic 3GPP Rel-15. + +NOTE 2: The summary description of configuration parameters outside the scope of 3GPP is not meant to restrict the mechanism or data type for such configuration. + +### 6.3.3 PUSCH Channel Model + +Per section 5.1.3.3.7 of the O-RAN AAL GAnP document [7] for the PUSCH High-PHY Profile, the PUSCH Channel model of the AAL\_UPLINK\_High-PHY Profile supports acceleration of PUSCH Data, DM-RS and PT-RS functionality. + +The set of accelerated functions associated with the processing of PUSCH TB(s) is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Combining +- Channel estimation (see DM-RS and PT-RS) +- Channel equalization (see DM-RS and PT-RS) +- Transform precoding (optional- only required for DFT-s-OFDM waveform) +- Demodulation +- Descrambling +- Rate de-matching +- LDPC decoding +- CRC check +- UCI Decoding + +The set of accelerated functions associated with the processing of PUSCH DM-RS is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Combining +- Demodulation +- Sequence detection + +The set of accelerated functions associated with the processing of PUSCH PT-RS is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Combining +- Demodulation +- Layer demapping + +- Sequence detection + +#### 6.3.3.1 PUSCH input and output for AAL\_UPLINK\_High-PHY Profile + +The AAL\_UPLINK\_High-PHY profile shall signal PUSCH allocation(s) per slot. + +From the AAL Application, the PUSCH interface receives the associated parameters for the PUSCH allocation. + +The output data consists of: + +- the CRC status for the PUSCH codeword, as well as optionally for individual CBs. +- in cases of successful CRC verification: the TB(s) output of the decoder. +- in case of UCI inclusion: the included UCI payload(s) + +#### 6.3.3.2 PUSCH Parameters + +The following parameters are required to be supported by the AAL implementation when offloading operations. The AAL Application shall supply all relevant parameters; for ease of reading, the parameters are organized per signal type: Data, DM-RS, PT-RS. + +PUSCH Data Parameters + +**Table 6.3.3.2-1: PUSCH Data Parameters** + +| AAL-LPU parameters | Short summary | 3GPP Spec Reference | +|---------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------| +| MAC TB | | | +| tb-Size | Transport block size. Computed at L2. | 3GPP TS 38.214, sec 6.1.4.2 | +| ← mac-PDU (if TB CRC passes) | This is an output: the TB corresponding to the PUSCH codeword | | +| UCI detection (if relevant) | | | +| csi-Part1BitLength | Size of UCI part 1 (or single UCI) | 3GPP TS 38.212, sec 6.3.2.4 | +| alphaScaling | Needed to compute number of coded symbols per layer | 3GPP TS 38.212, sec 6.3.2.4 | +| harq-ACK-BitLength | Number of HARQ-ACK bits | 3GPP TS 38.212, sec 6.3.2.4 | +| betaOffset-HARQ-ACK or codedModulationSymbPerLayer-ACK | betaOffsetHarq: Beta Offset for HARQ-ACK bits.<br><br>codedModulationSymbPerLayer: $Q'_{\{\text{ACK}\}}$ , the number of coded modulation symbols per layer for HARQ-ACK transmission | 3GPP TS 38.212, sec 6.3.2.4 | +| betaOffset-CSI-Part1 or codedModulationSymbPerLayer-CSI-Part1 | betaOffsetCsiPart1: Beta Offset for CSI part 1 bits.<br><br>codedModulationSymbPerLayer-CSI-Part1: $Q'_{\{\text{CSI-1}\}}$ , number of coded modulation symbols per layer for CSI part 1 transmission | 3GPP TS 38.212, sec 6.3.2.4 | +| betaOffset-CSI-Part2 | Beta Offset for CSI part 2 bits. | 3GPP TS 38.212, sec 6.3.2.4 | + +| | | | +|---------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------| +| uci-Part1ToPart2Correspondence | Mappings from Csi Part1 to length and priorities of CSI part 2 reports. Needed to compute in L1 the actual size of CSI part 2 | 3GPP TS 38.213, sec 9.3 | +| ← uci-Payload | This is an output: Uninterpreted UCI payload; part 1, if UCI is composed of two parts | | +| ← uci-Part2Payload | This is an output: Uninterpreted UCI part 2, if UCI is composed of two parts | | +| CRC Check | | | +| ← crc-Indication | This is an output: CRC Status for CW + other metrics (e.g. SINR) | 38.212, section 6.2.1 | +| CB CRC and CB Desegmentation | | | +| num-CB | number of expected code blocks | 3GPP TS 38.214, sec 5.2.2 | +| cb-PresentAndPosition[*] | Presence indicator (e.g. bitmap), for each CB | 3GPP TS 38.214, sec 6.2.3 | +| ← cb-CRC-Status | This is an output: CRC Status per CB + other metrics (e.g. SINR) | 3GPP TS 38.214, sec 6.2.3 | +| LDPC Decoding | | | +| rv-Index | redundancy version, per CW. Determines starting position $k_0$ in the circular buffer. In DCI, or from aggregation. | 3GPP TS 38.214, sec 6.1.4, sec 6.1.2.1 | +| targetCodeRate<br>or<br>(mcs-Table and mcs-Index) | targetCodeRate: R, target code rate<br>Explicit, for initial transmission.<br>Implicit from TBSize and allocation, for retransmissions.<br><br>MCS Table and MCS index: target code rate can be extracted from the index (first transmission), or as above for retransmissions. | 3GPP TS 38.214, sec 6.1.4.1 | +| newData | Signals whether there is a new transmission, or a retransmission (per CW) | 3GPP TS 38.212, sec 7.3.1.1<br>3GPP TS 38.214, sec 5.1.7.2 | +| harq-Process-ID | harq process number for the UL buffer | 3GPP TS 38.212, sec 7.3.1.1 | +| ldpc-BaseGraph | LDPC base graph to use (can be explicit, or derived from TB size and initial target rate) (per CW) | 3GPP TS 38.212, sec 7.2.2 | +| numIterations | Number of iterations for LDPC decoding. Refer to NOTE 1 at bottom of table. | Not applicable. | + +| | | | +|-------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------| +| | Note: This is an optional parameter | | +| earlyTermination-OnOff | To enable/disable early termination of LDPC decoding. Refer to NOTE 2 at bottom of table.<br><br>Note: This is an optional parameter | Not applicable. | +| Rate Dematching | | | +| tb-Size-LBRM<br>or<br>n-CB | TBS_{LBRM}: Reference TBS for allocations subject to rateMatching = limitedBufferRM; impacts circular buffer length<br><br>N_{CB} = circular buffer length, after account for any FBRM/LBRM considerations. | 3GPP TS 38.212, sec 5.4.2.1, 6.2.5 | +| num-CB | number of expected code blocks. Also uses the rate match size E_r, which is a computed field | 3GPP TS 38.212, sec 6.2.6 | +| cb-Size[*] | number of bits in each CB | 3GPP TS 38.212, sec 6.2.6 | +| CB Deconcatentation | | | +| num-CB | number of expected code blocks. Also uses the rate match size E_r, which is a computed field | 3GPP TS 38.212, sec 6.2.6 | +| cb-Size[*] | number of bits in each CB | 3GPP TS 38.212, sec 6.2.6 | +| Descrambling | | | +| n-ID-PUSCH or c-Init | n_{ID}: data scrambling identity (PCI by default)<br><br>c_{init}: scrambling initialization | 3GPP TS 38.211, sec 6.3.1.1 | +| rnti | RNTI associated with the PDSCH transmission | 3GPP TS 38.211, sec 6.3.1.1 | +| Demodulation | | | +| qam-ModOrder<br>or<br>(mcs-Table and mcs-Index) | Q_m: Signaled via MCS in DCI<br><br>MCS Table and MCS index: modulation can be extracted from the MCS table and index. | 3GPP TS 38.214, sec 6.1.4.1 | +| IDFT for DFT-s-OFDM | | | +| transformPrecoding | Signaled in DCI | 3GPP TS 38.214, sec 6.3.1.4 | +| Channel Estimation & Equalization | | | +| <see PUSCH DMRS> | | | + +| | | | | +|-------------------------------------|---------------------------|-------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------| +| <see PUSCH PTRS> | | | | +| Combining | | | | +| See section 6.2.7 and section 6.3.7 | | Combiner matrix is per PUSCH allocation | | +| RE Demapping | | | | +| Frequency Domain | bwp-Start | Start, w.r.t. CRB, of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUSCH allocation | 3GPP TS 38.211, sec 6.3.1.7 | +| | bwp-Size | Size of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUSCH allocation | 3GPP TS 38.211, sec 6.3.1.7 | +| | subcarrierSpacing | subcarrier spacing impacts waveform generation, including centering | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | num-DMRS-CDM-GrpsNoData | No PUSCH mapping on DMRS CDM groups marked as having no data. | 3GPP TS 38.212, sec 7.3.1.1 | +| | resourceAlloc | Bitmap-based (type 0) or offset & length (type 1) | 3GPP TS 38.214, sec 6.1.2.2 | +| | rb-Bitmap | <u>type 0</u> : allocation is based on this bitmap. In 3GPP, it is signaled at RB group resolution | 3GPP TS 38.214, sec 6.1.2.2.1<br>3GPP TS 38.212, sec 7.3.1.1.2 | +| | rb-Start | <u>type 1</u> : start of allocation derived from DCI RIV | 3GPP TS 38.214, sec 6.1.2.2.2<br>3GPP TS 38.212, sec 7.3.1.1.2 | +| | rb-Size | <u>type 1</u> : number of continuously allocated VRBs derived from DCI RIV | 3GPP TS 38.214, sec 5.1.2.2.2<br>3GPP TS 38.212, sec 7.3.1.1.2 | +| | intraSlotFrequencyHopping | indicates whether PUSCH allocation is based on intra-slot frequency hopping | 3GPP TS 38.212, sec 7.3.1.1<br>3GPP TS 38.214, sec 6.3 | +| | pusch-SecondHop-PRB | location of the second frequency hop | 3GPP TS 38.214, sec 6.3 | +| | tx-DirectCurrentLocation | indicates the subcarrier index within the carrier corresponding to the numerology of the corresponding uplink BWP | 3GPP TS 38.331, sec 6.3.2 | +| | shift7dot5kHz | Indicates whether there is 7.5 kHz shift or not. | 3GPP TS 38.331, sec 6.3.2 | +| Time Domain | startSymbolIndex | Start symbol index, for the allocation | 3GPP TS 38.214, Table 6.1.2.1-1 | +| | nrOfSymbols | Number of symbols, for the allocation | 3GPP TS 38.214, Table 6.1.2.1-1 | +| | cyclicPrefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | + +##### 1 PUSCH DM-RS Parameters + +**Table 6.3.3.2-2: PUSCH DM-RS Parameters** + +| AAL-LPU parameters | | Short summary | 3GPP Spec Reference | +|------------------------------------------------------------|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------| +| <b>DMRS Sequence</b> | | | | +| pusch-DMRS-ScramblingId<br><br>or<br><br>c-InitFirstSymbol | | pusch-DMRS-ScramblingId: $N_{\text{ID}}$ , scrambling identifier for $n_{\text{SCID}}$<br><br>c-InitFirstSymbol: $c_{\text{init}}[l]$ , scrambling initialization for DMRS symb l (CP-OFDM) or for entire DMRS (Rel-15 DFT-S-OFDM) | 3GPP TS 38.211, sec 6.4.1.1.1/2 | +| n-SCID | | sequence index (from DCI; defaults to 0) | 3GPP TS 38.211, sec 6.4.1.1.1/2 | +| pusch-DMRS-Identity | | $N_{\text{ID}}^{\text{RS}}$ , same as $N_{\text{ID}}^{\text{PUSCH}}$ , or PCI (DFT-S-OFDM) | 3GPP TS 38.211, sec 6.4.1.1.2 | +| groupOrSequenceHopping | | indicates whether sequence or group hopping is enabled | 3GPP TS 38.211, sec 6.4.1.1.2 | +| low-PAPR-GroupNumber | | U: low PAPR group number [DFT-s-OFDM] | 3GPP TS 38.211, sec 5.2.2 | +| low-PAPR-SequenceNumber | | V: low PAPR sequence number [DFT-s-OFDM] | 3GPP TS 38.211, sec 5.2.2 | +| <b>Demodulation</b> | | | | +| transformPrecoding | | CP-OFDM: PUSCH DM-RS uses QPSK modulation<br>DFT-s-OFDM: PUSCH DMRS uses low-PAPR sequences | 3GPP TS 38.211, sec 6.4.1.1.1/2 | +| <b>Combining</b> | | | | +| [see PUSCH data combining] | | DMRS follows PUSCH-data combining | | +| ul-TPMI-Index | | [optional] PMI of the UE, can help with combiner formation | 3GPP TS 38.211, sec 6.3.1.5 | +| <b>RE Demapping</b> | | | | +| Frequency Domain | bwp-Start | see PUSCH data table | 3GPP TS 38.211, sec 6.3.1.7 | +| | bwp-Size | see PUSCH data table | 3GPP TS 38.211, sec 6.3.1.7 | +| | subcarrierSpacing | see PUSCH data table | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | dmrs-Ports | DMRS ports per layer; OC weights are applied to DM-RS REs, based on DM-RS CDM group and identifier for each DM-RS port. | 3GPP TS 38.211, sec 6.4.1.1.3 | + +| | | | | +|-------------|-----------------|--------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------| +| Time Domain | ul-DMRS-SymbPos | location of DMRS in a slot sufficiently captures the impact of upper layer parameters, e.g. mapping type, additional pos | 3GPP TS 38.211, sec 6.4.1.1.3 | +| | dmrs-ConfigType | DMRS configuration type controls port to CDM group correspondence | 3GPP TS 38.211, sec 6.4.1.1.3 | +| | dmrs-Ports | DMRS ports per layer; OC weights are applied to DM-RS REs, based on DM-RS CDM group and identifier for each DM-RS port. | 3GPP TS 38.211, sec 6.4.1.1.3 | +| | cyclicPrefix | see PUSCH data table | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | + +NOTE 1: As for numIterations parameter in LDPC Decoding, there can be several use cases to apply the optimal number of LDPC decoding iterations, such as- 1) in a case when more number of LDPC iterations (as part of the entire allowed processing resources) should be allocated to URLLC traffic than eMBB traffic if they coexist, 2) in a case when cell coverage would improve with increased number of LDPC iterations for cell-edge users (e.g., with minimum MCS and small PDU length), and 3) in a case when VoIP such as small data size would be benefited from increased number of LDPC iterations. The numIterations parameter in LDPC Decoding is assumed to be always set by AAL application as same as other parameters in LDPC Decoding, and the support of the numIterations parameter in AALI implementation at HWA is optional (e.g., the default value is “0”, which is set by AAL application when AALI implementation does not support this parameter. In that case, AALI implementation may simply choose to ignore this parameter (or the value)). Note that the aforementioned examples are not meant to be an exhaustive list, and AAL applications may choose to set this parameter for other use cases not mentioned here. The actual range of numIterations parameter value would be as per the AALI implementation. + +NOTE 2: As for earlyTermination-OnOff parameter in LDPC Decoding, there would be several use cases to optimize the early termination of LDPC decoding iterations, such as – 1) in a case where it would be preferable to prioritize energy efficiency rather than minimizing the BLER (which leads to earlyTermination-OnOff to be on), and 2) in a case where early termination would be preferable for configured grant. The earlyTermination-OnOff parameter in LDPC Decoding is assumed to be always set by AAL application as same as other parameters in LDPC Decoding, and the support of the earlyTermination-OnOff parameter in AALI implementation at HWA is optional (e.g., the default value is “0”, which means early termination is off. AAL application will ONLY set this value to 1 (i.e. ON) when AALI implementation supports this feature.). Note that the aforementioned examples are not meant to be an exhaustive list, and AAL applications may choose to set this parameter for other use cases not mentioned here. + +##### PUSCH PT-RS Parameters + +**Table 6.3.3.2-3: PUSCH PT-RS Parameters** + +| AAL-LPU parameters | Short summary | 3GPP Spec Reference | +|--------------------|-----------------------------------------------------|--------------------------------------------------------------| +| Sequence Detection | | | +| num-PTRS-Ports | number of PT-RS ports (Rel-15: only one) | 3GPP TS 38.212, sec 7.3.1.1.2 | +| ptrs-DMRS-port[*] | DM-RS ports associated with each of the PT_RS ports | 3GPP TS 38.214, sec 6.2.3.1<br>3GPP TS 38.212, sec 7.3.1.1.2 | + +| | | | | +|---------------------------------------|-------------------|----------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------| +| ul-PTRS-SampleDensity | | $N_{\text{group}}^{\text{PT-RS}}$ : Number of PT-RS groups [DFTS-OFDM case] | 3GPP TS 38.211, sec 6.4.1.2.1.2<br>3GPP TS 38.214, sec 6.2.3.2 | +| ul-PTRS-TimeDensityTransformPrecoding | | $N_{\text{samp}}^{\text{group}}$ : Number of samples per PT-RS group [DFTS-OFDM case] | 3GPP TS 38.211, sec 6.4.1.2.1.2<br>3GPP TS 38.214, sec 6.2.3.2 | +| n-ID-PUSCH | | $N_{\text{ID}}$ : Identity for associated PUSCH | 3GPP TS 38.211, sec 6.4.1.2.1.2 | +| Layer Demapping | | | | +| num-PTRS-Ports | | number of PT-RS ports | 3GPP TS 38.212, sec 7.3.1.1.2 | +| ptrs-DMRS-Port[*] | | DM-RS ports associated with each of the PT-RS ports | 3GPP TS 38.214, sec 6.2.3.1<br>3GPP TS 38.212, sec 7.3.1.1.2 | +| Combining | | | | +| [same as the associated DMRS Port(s)] | | | | +| RE Demapping | | | | +| Frequency Domain | bwp-Start | see PUSCH data table | 3GPP TS 38.211, section 7.3.1.6 | +| | bwp-Size | see PUSCH data table | 3GPP TS 38.211, section 7.3.1.6 | +| | subcarrierSpacing | see PUSCH data table | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | ptrs-FreqDensity | $K_{\text{PT-RS}}$ , frequency density (includes the case where there is no PT-RS) | 3GPP TS 38.214, sec 6.2.3.1, table 6.2.3.1-2 | +| | ptrs-RE-Offset | $k_{\text{ref}}^{\text{RE}}$ , re offset (can depend on DMRS association and RRC signaling of resourceElementOffset) | 3GPP TS 38.211, sec 6.4.1.2.2, table 6.4.1.2.2.1-1<br>3GPP TS 38.331, sec 6.3.1 | +| | rnti | RNTI associated with the PUSCH transmission | 3GPP TS 38.211, sec 7.4.1.2.2 | +| Time Domain | ptrs-TimeDensity | $L_{\text{PT-RS}}$ , time density (includes the case where there is no PT-RS) [CP-OFDM] | 3GPP TS 38.214, sec 6.2.3.1, table 6.2.3.1-1 | +| | ul-DMRS-SymbPos | see PUSCH DMRS table symbols used for DMRS (PT-RS skips over these) | 3GPP TS 38.211, sec 7.4.1.1.2 and Tables 7.4.1.1.2-3 and 7.4.1.1.2-4 | +| | cyclicPrefix | see PUSCH data table | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | +| Power Offset | | | | +| | ul-PTRS-Power | $\alpha_{\text{PTRS}}^{\text{PUSCH}}$ : PUSCH to PT-RS power ratio per layer per RE | 3GPP TS 38.214, sec 6.2.3.1, Table 6.2.3.1-3 | + +1 + +### 6.3.4 PUCCH Channel Model + +Per section 5.1.3.3.7 of the O-RAN AAL GANP document [7] for the PUCCH High-PHY Profile, the PUCCH Channel model of the AAL\_UPLINK\_High-PHY Profile supports acceleration of PUCCH Format 0, Format 1 UCI and DM-RS and Formats 2,3,4 UCI and DM-RS. + +The set of accelerated functions associated with the processing of PUCCH Format 0 is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Sequence detection + +The set of accelerated functions associated with the processing of PUCCH Format 1 UCI is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation +- Channel equalization +- Demodulation + +The set of accelerated functions associated with the processing of PUCCH Format 1 DM-RS is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Combining +- Demodulation +- Sequence detection + +The set of accelerated functions associated with the processing of PUCCH Formats 2, 3, 4 is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation +- Channel equalization +- Transform precoding (optional- only required for DFT-s-OFDM waveform) +- Demodulation +- Descrambling +- Rate de-matching +- Polar/Block decoding +- CRC check + +The set of accelerated functions associated with the processing of PUCCH Formats 2, 3, 4 DM-RS is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping + +- Combining +- Demodulation +- Sequence detection + +#### 6.3.4.1 PUCCH input and output for AAL\_UPLINK\_High-PHY Profile + +The AAL\_UPLINK\_High-PHY profile shall signal PUCCH resource(s) per slot. + +From the AAL Application, the PUCCH interface receives the associated parameters for the configuration of the PUCCH resource. + +The output data consists of: + +- the CRC or detection status of the PUCCH UCI payload (HARQ, SR or CSI), as well as related metrics (e.g. SINR) +- The UCI Payload: HARQ, SR (Formats 0/1) or transparent UCI payload(s) (Formats 2/3/4). + +#### 6.3.4.2 PUCCH Parameters + +The following parameters are required to be supported by the AAL implementation when offloading operations. The AAL Application shall supply all relevant parameters; for ease of reading, the parameters are grouped as follows, in alignment with the O-RAN AAL GAnP document [7]: PUCCH Format 0, PUCCH Format 1 (UCI and DMRS), PUCCH Formats 2/3/4 (UCI and DMRS). Only one of these sets of parameters is applicable to any one PUCCH resource: + +##### PUCCH Format 0 Parameters + +**Table 6.3.4.2-1: PUCCH Format 0 Parameters** + +| AAL-LPU parameters | Short summary | 3GPP Spec Reference | +|------------------------------------|-----------------------------------------------------------------------------------------------------------|-------------------------------| +| UCI | | | +| sr-BitLen | indicates whether SR can be indicated (lengths 0 or 1) | 3GPP TS 38.213, sec 9.2 | +| bitLen-HARQ | indicates number of HARQ bits | 3GPP TS 38.213, sec 9.2 | +| ← sr-Indication<br>← harq-Value[*] | This is an output: SR and HARQ observations, or outcome of detection; Also: metrics like SINR, RSRP, etc. | 3GPP TS 38.213, sec 9.2 | +| Sequence Detection | | | +| pucch-GroupHopping | indicates whether group, sequence or no hopping is applied | 3GPP TS 38.211, sec 6.3.2.2.1 | +| n-ID-PUCCH-Hopping | hopping identifier | 3GPP TS 38.211, sec 6.3.2.2.1 | +| initialCyclicShift | initial cyclic shift | 3GPP TS 38.211, sec 6.3.2.2.2 | +| RE Demapping | | | + +| | | | | +|------------------|---------------------------|----------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------| +| Frequency Domain | bwp-Start | Start, w.r.t. CRB, of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUCCH allocation | 3GPP TS 38.211, sec 6.3.1.7 | +| | bwp-Size | Size of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUCCH allocation | 3GPP TS 38.211, sec 6.3.1.7 | +| | subcarrierSpacing | subcarrier spacing impacts waveform generation, including centering | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | prb-Start | RB_{BWP}^{offset}, PRB offset, prior to any hopping | 3GPP TS 38.213, sec 9.2.1 | +| | intraSlotFrequencyHopping | indicates whether the allocation hops in frequency or not | 3GPP TS 38.211, sec 6.3.2.2.1 | +| | secondHop-PRB | RB offset of the second hop, in case of intra-slot frequency hopping | 3GPP TS 38.213, sec 9.2.1 | +| Time Domain | startSymbolIndex | first symbol for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2 | +| | nrOfSymbols | number of symbols for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2 | +| | cyclicPrefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | + +1 + +2 PUCCH Format 1 UCI Parameters + +3 + +**Table 6.3.4.2-2: PUCCH Format 1 UCI Parameters** + +| AAL-LPU parameters | Short summary | 3GPP Spec Reference | +|------------------------------------|---------------------------------------------------------------------------------------------------------|----------------------------------------------------------------| +| UCI | | | +| sr-BitLen | indicates whether SR can be indicated (lengths 0 or 1) | 3GPP TS 38.213, sec 9.2.4 | +| bitLen-HARQ | indicates number of HARQ bits | 3GPP TS 38.213, sec 9.2.2 | +| ← sr-Indication<br>← harq-Value[*] | This is an output: SR and HARQ observations, if any (or outcome of detection + metrics like SINR, RSRP) | | +| Demodulation | | | +| pucch-GroupHopping | indicates whether group, sequence or no hopping is applied | 3GPP TS 38.211, sec 6.3.2.2.1 | +| n-ID-PUCCH-Hopping | hopping identifier | 3GPP TS 38.211, sec 6.3.2.2.1 | +| initialCyclicShift | initial cyclic shift | 3GPP TS 38.211, sec 6.3.2.2.2 | +| timeDomain-OCC-Idx | index of orthogonal sequence w | 3GPP TS 38.211, sec 6.3.2.4.1<br>3GPP TS 38.213, section 9.2.1 | + +| | | | | +|-------------------------------------|---------------------------|----------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------| +| sr-BitLen and bitLen-HARQ | | Number of bits determines modulation: BPSK or QPSK | 3GPP TS 38.211, sec 6.3.2.4.1 | +| Channel Estimation and Equalization | | | | +| [see PUCCH Format 1 DM-RS] | | | | +| RE Demapping | | | | +| Frequency Domain | bwp-Start | Start, w.r.t. CRB, of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUCCH allocation | 3GPP TS 38.211, sec 6.3.1.7 | +| | bwp-Size | Size of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUCCH allocation | 3GPP TS 38.211, sec 6.3.1.7 | +| | subcarrierSpacing | subcarrier spacing impacts waveform generation, including centering | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | prb-Start | RB_{BWP}^{\offset}: PRB offset, prior to any hopping | 3GPP TS 38.213, sec 9.2.1 | +| | intraSlotFrequencyHopping | indicates whether the allocation hops in frequency or not | 3GPP TS 38.211, sec 6.3.2.2.1 | +| | secondHop-PRB | RB offset of the second hop, in case of intra-slot frequency hopping | 3GPP TS 38.213, sec 9.2.1 | +| Time Domain | startSymbolIndex | first symbol for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2 | +| | nrOfSymbols | number of symbols for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2 | +| | cyclicPrefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | + +1 + +2 PUCCH Format 1 DM-RS Parameters + +3 + +**Table 6.3.4.2-3: PUCCH Format 1 DM-RS Parameters<sup>2</sup>** + +| AAL-LPU parameters | Short summary | 3GPP Spec Reference | +|--------------------|------------------------------------------------------------|--------------------------------------------| +| Descrambling | | | +| pucch-GroupHopping | indicates whether group, sequence or no hopping is applied | 3GPP TS 38.211, sec 6.3.2.2.1, 6.4.1.3.1.1 | +| n-ID-PUCCH-Hopping | hopping identifier | 3GPP TS 38.211, sec 6.3.2.2.1, 6.4.1.3.1.1 | +| initialCyclicShift | initial cyclic shift | 3GPP TS 38.211, sec 6.3.2.2.2, 6.4.1.3.1.1 | + +<sup>2</sup> All the parameters in this PUCCH Format 1 DM-RS table are also present in the PUCCH Format 1 UCI table + +| | | | | +|-------------------------|---------------------------|----------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------| +| timeDomain-OCC-Idx | | index of orthogonal sequence w | 3GPP TS 38.211, sec 6.3.2.4.1, 6.4.1.3.1.1<br>3GPP TS 38.213, sec 9.2.1 | +| <b>RE Demapping</b> | | | | +| <b>Frequency Domain</b> | bwp-Start | Start, w.r.t. CRB, of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUCCH allocation | 3GPP TS 38.211, sec 6.3.1.7, 6.4.1.3.1.2 | +| | bwp-Size | Size of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUCCH allocation | 3GPP TS 38.211, sec 6.3.1.7, 6.4.1.3.1.2 | +| | subcarrierSpacing | subcarrier spacing impacts waveform generation, including centering | 3GPP TS 38.211, sec 4.2, 5.3.1, 6.4.1.3.1.2 | +| | prb-Start | PRB offset, prior to any hopping | 3GPP TS 38.213, sec 9.2.1<br><br>3GPP TS 38.211, sec 6.4.1.3.1.2 | +| | intraSlotFrequencyHopping | indicates whether the allocation hops in frequency or not | 3GPP TS 38.211, sec 6.3.2.2.1, 6.4.1.3.1.2 | +| | secondHop-PRB | RB offset of the second hop, in case of intra-slot frequency hopping | 3GPP TS 38.213, sec 9.2.1<br><br>3GPP TS 38.211, sec 6.4.1.3.1.2 | +| <b>Time Domain</b> | startSymbolIndex | first symbol for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2<br><br>3GPP TS 38.211, sec 6.4.1.3.1.2 | +| | nrOfSymbols | number of symbols for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2<br><br>3GPP TS 38.211, sec 6.4.1.3.1.2 | +| | cyclicPrefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation | 3GPP TS 38.211, sec 4.2, 5.3.1, 6.4.1.3.1.2<br>3GPP TS 38.214, Table 5.1.2.1-1 | + +PUCCH Format 2/3/4 UCI Parameters + +**Table 6.3.4.2-4: PUCCH Formats 2/3/4 Parameters** + +| AAL-LPU parameters | Short summary | 3GPP Spec Reference | +|--------------------|------------------------------------------------|------------------------------------------------------------| +| <b>UCI</b> | | | +| sr-BitLen | $O^{\{SR\}}$ , indicates the number of SR bits | 3GPP TS 38.213, sec 9.2<br>3GPP TS 38.212, Table 6.3.1.4-1 | + +| | | | +|----------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------| +| bitLen-HARQ | $O^{\{ACK\}}$ , indicates number of HARQ bits | 3GPP TS 38.213, sec 9.2<br>3GPP TS 38.212, Table 6.3.1.4-1 | +| csi-Part1BitLength | $O^{\{CSI-part1\}}$ , indicates the number of CSI part 1 bits | 3GPP TS 38.213, sec 9.2<br>3GPP TS 38.212, Table 6.3.1.4-1 | +| uci-Part1ToPart2Correspondence | Mappings from CSI Part1 to length and priorities of CSI part 2 reports. Needed to compute in L1 the actual size of CSI part 1 (Formats 3,4) | 3GPP TS 38.213, sec 9.2.5 | +| ← uci-Payload | This is an output: Uninterpreted UCI payload (or outcome of decoding + metrics like SINR, RSRP, etc.) | 3GPP TS 38.213, sec 9.2 | +| ← uci-Part2Payload | This is an output: Uninterpreted UCI part 2, if UCI is composed of two parts | | +| formatType | 2, 3 or 4 | 3GPP TS 38.213, sec 9.2.2 | +| CRC check | | | +| <acceleration based on hardcoded parameters> | CRC size and generator depend on the payload size A, and fixed parameters | 3GPP TS 38.212, sec 6.3.1.2 | +| Polar/Block decoding | | | +| <acceleration based on hardcoded parameters> | Encoding depends on the payload size A, and corresponding number of code blocks, and fixed parameters | 3GPP TS 38.212, sec 6.3.1.3 | +| Rate de-matching | | | +| nrOfSymbols | $N_{\{symb,UCI\}^{\{PUCCH,*\}}}$ : number of symbols carrying UCI for PUCCH formats 2/3/4 respectively | 3GPP TS 38.212, Table 6.3.1.4-1 | +| pre-DFT-OCC-Idx | $N_{\{SF\}^{\{PUCCH,*\}}}$ : spreading factor for PUCCH formats 4 | 3GPP TS 38.212, Table 6.3.1.4 | +| prb-Size | $N_{\{PRBI\}^{\{PUCCH,*\}}}$ : actual number of RBs used by the UE for this allocation, for each format, respectively | 3GPP TS 38.213, sec 9.2.1 | +| pi2-BPSK | $\pi/2$ -BPSK: indicates that Formats 3-4 use $\pi/2$ -BPSK, rather than QPSK modulation<br>NOTE: QPSK for Format 2 | 3GPP TS 38.211, sec 6.3.2.6.2, sec 6.3.2.5.2 | +| maxCodeRate | $R_{\{UCI\}^{\{max\}}}$ : Max coding rate to determine how to feedback UCI | 3GPP TS 38.212, Table 6.3.1.4.1-1 | +| Descrambling | | | +| mti | RNTI associated with the PUCCH transmission | 3GPP TS 38.211, sec 6.3.2.5.1 and 6.3.2.6.1 | +| nId-PUCCH-Scrambling | $n_{\{ID\}}$ : scrambling id (PCI by default) | 3GPP TS 38.211, sec 6.3.2.5.1 and 6.3.2.6.1 | + +| | | | | +|----------------------------------------------------|---------------------------|-----------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------| +| or<br>c-Init | | c_{init}: scrambling initialization | | +| Demodulation | | | | +| <acceleration based on already-defined parameters> | | See $\pi/2$ -BPSK parameter | | +| Block-wise Despreading | | | | +| pre-DFT-OCC-Idx | | index of orthogonal sequence for Format 4. | 3GPP TS 38.213, section 9.2.1 | +| pre-DFT-OCC-Len | | length of orthogonal sequence for Format 4. | 3GPP TS 38.213, section 9.2.1 | +| IDFT for DFT-s-OFDM | | | | +| prb-Size | | Actual number of RBs used by the UE for this allocation (Format 3) | 3GPP TS 38.213, sec 9.2.1 | +| number of symbols | | number of symbols for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2 | +| Channel Estimation and Equalization | | | | +| [see PUCCH Format 2/3/4 DM-RS] | | | | +| RE Demapping | | | | +| Time Domain | bwp-Start | Start, w.r.t. CRB, of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUCCH allocation | 3GPP TS 38.211, sec 6.3.1.7 | +| | bwp-Size | Size of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUCCH allocation | 3GPP TS 38.211, sec 6.3.1.7 | +| | subcarrierSpacing | subcarrier spacing impacts waveform generation, including centering | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | prb-Start | PRB offset, prior to any hopping | 3GPP TS 38.213, sec 9.2.1 | +| | prb-Size | $N_{\text{PRBI}}^{\text{PUCCH,*}}$ : actual number of RBs used by the UE for this allocation, for each format, respectively | 3GPP TS 38.213, sec 9.2.1 | +| | intraSlotFrequencyHopping | indicates whether the allocation hops in frequency or not | 3GPP TS 38.211, sec 6.3.2.2.1<br>3GPP TS 38.212, sec 6.3.1.4 | +| | secondHop-PRB | RB offset of the second hop, in case of intra-slot frequency hopping | 3GPP TS 38.213, sec 9.2.1 | +| Time Domain | startSymbolIndex | first symbol for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2 | + +| | | | | +|--|--------------|---------------------------------------------------------------------------------------------|-------------------------------------------------------------------| +| | nrOfSymbols | $N_{\{\text{symb,UCI}\}^{\{\text{PUCCH,*}\}}}$ : number of symbols for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2 | +| | cyclicPrefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | + +1 + +2 PUCCH Format 2/3/4 DM-RS Parameters + +3 + +**Table 6.3.4.2-5: PUCCH Formats 2/3/4 DM-RS Parameters** + +| AAL-LPU parameters | | Short summary | 3GPP Spec Reference | +|-------------------------------------------------------|---------------------------|------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------| +| Descrambling | | | | +| nId0-PUCCH-DMRS-Scrambling<br>or<br>c-InitFirstSymbol | | $N_{\{\text{ID}\}^0}$ : scrambling ID 0 for Format 2 | 3GPP TS 38.211, sec 6.4.1.3.2.1 | +| | | $c_{\{\text{init}\}[l]}$ : scrambling initialization, per DMRS symb l. | | +| pucch-GroupHopping | | indicates whether group, sequence or no hopping is applied (Formats 3/4) | 3GPP TS 38.211, sec 6.3.2.2.1 | +| n-ID-PUCCH-Hopping | | hopping identifier (Formats 3/4) | 3GPP TS 38.211, sec 6.3.2.2.1 | +| initialCyclicShift | | initial cyclic shift (Formats 3/4) | 3GPP TS 38.211, sec 6.3.2.2.2 | +| pre-DFT-OCC-Idx | | index of orthogonal sequence for Format 4. | 3GPP TS 38.213, section 9.2.1 | +| pre-DFT-OCC-Len | | length of orthogonal sequence for Format 4. | 3GPP TS 38.213, section 9.2.1 | +| RE Demapping | | | | +| Frequency Domain | bwp-Start | Start, w.r.t. CRB, of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUCCH allocation | 3GPP TS 38.211, sec 6.3.1.7 | +| | bwp-Size | Size of bandwidth part: VRBs indexing is relative to the Bandwidth part for the PUCCH allocation | 3GPP TS 38.211, sec 6.3.1.7 | +| | subcarrierSpacing | subcarrier spacing impacts waveform generation, including centering | 3GPP TS 38.211, sec 4.2, 5.3.1 | +| | prb-Start | PRB offset, prior to any hopping | 3GPP TS 38.213, sec 9.2.1 | +| | prb-Size | $N_{\{\text{PRB}\}^{\{\text{PUCCH,*}\}}}$ : Actual number of RBs used by the UE for this allocation, for each format, respectively | 3GPP TS 38.213, sec 9.2.1 | +| | intraSlotFrequencyHopping | indicates whether the allocation hops in frequency or not | 3GPP TS 38.211, sec 6.3.2.2.1<br>3GPP TS 38.212, sec 6.3.1.4 | + +| | | | | +|--------------------|------------------|--------------------------------------------------------------------------------------------|-------------------------------------------------------------------| +| | secondHop-PRB | RB offset of the second hop, in case of intra-slot frequency hopping | 3GPP TS 38.213, sec 9.2.1 | +| <b>Time Domain</b> | startSymbolIndex | first symbol for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2 | +| | nrOfSymbols | $N_{\text{symb,UCI}}^{\text{PUCCH,*}}$ : number of symbols for the PUCCH allocation | 3GPP TS 38.213, sec 9.2.2 | +| | add-DMRS-Flag | Indicates 2 additional DMRS symbols per hop of a PUCCH Format 3 or 4 (depending on length) | 3GPP TS 38.213, sec 9.2.2 | +| | cyclicPrefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | + +### 6.3.5 SRS Channel Model + +Per section 5.1.3.3.7 of the O-RAN AAL GAnP document [7] for the SRS High-PHY Profile, the SRS Channel model of the AAL\_UPLINK\_High-PHY Profile supports acceleration of SRS. + +The set of accelerated functions associated with the processing of SRS is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Channel estimation + +#### 6.3.5.1 SRS input and output for AAL\_UPLINK\_High-PHY Profile + +The AAL\_UPLINK\_High-PHY profile shall signal SRS Resource(s) per slot. + +From the AAL Application, the SRS interface receives the associated parameters for the configuration of the SRS Resource. + +The output data consists of the channel estimation metrics + +#### 6.3.5.2 SRS Parameters + +The following parameters are required to be supported by the AALI implementation when offloading operations. The AAL Application shall supply all relevant parameters; for ease of reading, the parameters are grouped as follows, in alignment with the O-RAN AAL GAnP document [7]: + +SRS Parameters + +**Table 6.3.5.2-1: SRS Parameters** + +| AAL-LPU parameters | Short summary | 3GPP Spec Reference | +|--------------------|---------------|---------------------| +| | | | + +| | | | | | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------|------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------|-------------------------------------| +| Channel Estimation (report types are per implementation and may be optional. Combinations - of one or more, or even none - of report types linked to an SRS resource are also possible, and AAL-LPU shall indicate this in a capability) | | | | | +| srs-Usage | | usage of the SRS resource: beamManagement, codebook, nonCodebook, antennaSwitching | | 3GPP TS 38.331, sec 6.3.2 | +| report type | | Requested report type; may depend on usage | | | +| <b>SVD report type</b> | iq-Representation | | Size and formats e.g. BFP, etc used for encoding channel eigenvector matrices (format of U, V entries) | See section 6.2.7 and section 6.3.7 | +| | singularValueRepresentation | | Size and formats e.g. BFP, etc used for encoding channel singular values | | +| | prg-Size | | frequency resolution of SVD report, e.g. RB, PRG, etc | | +| | ← channel-SVD-Representation | | at the required resolution | | +| <b>H (raw channel) report type</b> | iq-Representation | | Size and formats e.g. BFP, etc used for encoding channel matrices (format of H entries) | See section 6.2.7 and section 6.3.7 | +| | prg-Size | | frequency resolution of H report, e.g. RB, PRG, etc | | +| | ← channel-IQ-Matrix | | at the required resolution | | +| <b>SINR report type</b> | prg-Size | | frequency resolution of SINR report, e.g. RB, PRG, etc | | +| | ← sinr-Report | | at the required resolution (per symbol) | | +| <b>2D-DFT basis report type</b> | prg-Size | | Frequency resolution of 2D-DFT reports, e.g. RB, PRG, etc | | +| | ← channel-2D-DFT-Representation | beam-Indices | Strongest K_DFT_beams 2D-DFT beam indices per SRS basis vector | | +| | | beam-Values | Measured beam values for K_DFT_beams strongest 2D-DFT beams per SRS basis vector | | +| | | Rank | Channel rank | | + +| | | | | +|--------------------------------------|-------------------------------------------------------|------------------------------------------------------------|----------------------------------------------------------------------------------------------------------| +| Additional report types can be added | | | | +| RE demapping | | | | +| numAntPorts | | $N_{\text{ap}}^{\text{SRS}}$ : number of SRS Ports | 3GPP TS 38.211, sec 6.4.1.4.1 | +| cyclicShift | | $n_{\text{SRS}}^{\text{CS}}$ : cyclic shift | 3GPP TS 38.211, sec 6.4.1.4.2 | +| sequence-ID | | $n_{\text{ID}}^{\text{SRS}}$ : SRS sequence identity | 3GPP TS 38.211, sec 6.4.1.4.2 | +| groupOrSequenceHopping | | SRS Group and Sequence Hopping: Group, sequence or neither | 3GPP TS 38.211, sec 6.4.1.4.2 | +| Frequency domain | bwp-Start | | Start, w.r.t. CRB, of bandwidth part: VRBs indexing is relative to the Bandwidth part for the allocation | +| | bwp-Size | | Size of bandwidth part: VRBs indexing is relative to the Bandwidth part for the allocation | +| | subcarrierSpacing | | subcarrier spacing impacts waveform generation, including centering | +| | combSize | | $K_{\text{TC}}$ : transmission comb number | +| | combOffset | | $\bar{k}_{\text{TC}}$ : transmission comb offset | +| | frequencyShift | | $n_{\text{shift}}$ : frequency domain shift value | +| | frequencyPosition | | $n_{\text{RRC}}$ : frequency domain position | +| | Frequency Hopping Signaling Alt-1: RRC parameters | configIndex | $C_{\text{SRS}}$ : SRS bandwidth config index | +| | | bandwidthIndex | $B_{\text{SRS}}$ : SRS bandwidth index | +| | | frequencyHopping | $b_{\text{hop}}$ : frequency hopping | +| | Frequency Hopping Signaling Alt-2: L2 computed fields | srs-BandwidthSize | $m_{\text{SRS},b}$ : SRS bandwidth size | +| | | srs-BandwidthStart | PRB index (w.r.t. CRB0) for the start of SRS signal transmission, per symbol | + +| | | | | +|-------------|-------------------|-----------------------------------------------------------------------------|-------------------------------| +| Time domain | numSymbols | $N_{\text{symb}}^{\text{SRS}}$ : number of consecutive OFDM symbols for SRS | 3GPP TS 38.211, sec 6.4.1.4.1 | +| | timeStartPosition | $l_0$ : the starting position in the time domain given | 3GPP TS 38.211, sec 6.4.1.4.1 | +| | t-SRS | $T_{\text{SRS}}$ : periodicity for SRS | 3GPP TS 38.211, sec 6.4.1.4.3 | +| | t-Offset | $T_{\text{offset}}$ : slot offset | 3GPP TS 38.211, sec 6.4.1.4.3 | +| | numRepetitions | Corresponds to R: Repetition factor | 3GPP TS 38.211, sec 6.4.1.4.3 | + +### 6.3.6 PRACH Channel Model + +Per section 5.1.3.3.7 of the O-RAN AAL GAnP document [7] for the PRACH High-PHY Profile, the PRACH Channel model of the AAL\_UPLINK\_High-PHY Profile supports acceleration of PRACH. + +The set of accelerated functions associated with the processing of PRACH is as follows: + +- IQ decompression<sup>1</sup> +- RE de-mapping +- Root sequence generation and correlation +- IFFT +- Noise estimation +- Peak search for power delay profile +- Preamble detection and delay/timing advance estimation + +#### 6.3.6.1 PRACH input and output for AAL\_UPLINK\_High-PHY Profile + +The AAL\_UPLINK\_High-PHY profile shall signal PRACH Resource Occasion(s) per slot. + +From the AAL Application, the PRACH interface receives the associated parameters for the configuration of the PRACH Occasion. + +The output data consists of the PRACH detection outcome and metrics + +#### 6.3.6.2 PRACH Parameters + +The following parameters are required to be supported by the AALI implementation when offloading operations. The AAL Application shall supply all relevant parameters; for ease of reading, the parameters are grouped as follows, in alignment with the O-RAN AAL GAnP document [7]: + +PRACH Parameters + +**Table 6.3.6.2-1: PRACH Parameters** + +| AAL-LPU parameters | Short summary | 3GPP Spec Reference | +|--------------------|---------------|---------------------| +|--------------------|---------------|---------------------| + +| | | | +|---------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------| +| Preamble Detection + Delay Estimation | | | +| ← preambleIndex[*] | list of detected preambles, per RO | | +| ← timingAdvanceOffset[*] | per detected preamble & RO: timing advance | 3GPP TS 38.213, sec 4.2 | +| ← detection metrics:<br>• preamblePwr[*]<br>• preamble-SNR[*] | per detected preamble & RO: SINR, Rx Power, etc. | | +| Peak Search | | | +| <see Root Sequence Correlation> | Correlation is over the root sequences with valid preambles in each RACH occasion. The mechanism for detecting peaks is per implementation. | | +| Noise Estimation | | | +| <per implementation> | One possibility is to perform noise estimation on an unused root sequence, in which case the identity of the unused root sequence can be signaled.<br><br>NOTE: Noise estimation is implementation-specific, and this channel profile does not currently assume any one implementation. | | +| iFFT | | | +| <based on RE mapping parameters and sequence length> | The formula for generating the PRACH waveform is provided in the reference to the right. | 3GPP TS 38.211, sec 5.3.2 | +| Root Sequence Correlation | | | +| restrictedSetConfig | Configuration of an unrestricted set or one of two types of restricted sets, type A and type B | 3GPP TS 38.211, sec 6.3.3.1 | +| numPreambleIndices | $N_{\text{preamble}}^{\text{total}}$ : number of preambles, per PRACH occasions | 3GPP TS 38.213, section 8.1 | +| startPreambleIndex | preamble index start for each PRACH occasion in this PRACH configuration | 3GPP TS 38.213, section 8.1 | +| prach-ZeroCorrConf | PRACH Zero CorrelationZone Config which is used $N_{\text{cs}}$ : cyclic shift interval | 3GPP TS 38.211, sec 6.3.3.1 | +| RE Demapping | | | + +| | | | | +|-------------------------|-------------------------|-----------------------------------------------------------------------------------------------------|-------------------------------------------------------------------| +| <b>Frequency Domain</b> | num-FD-RA | From M: number of FDM occasions per PRACH slot | 3GPP TS 38.211, sec 6.3.3.2 | +| | prach-FrequencyOffset | $k1[*]$ : offset in units of BWP REs (per RO) | 3GPP TS 38.211, sec 5.3.2 | +| | ul-BWP-PUSCH-SCS | $\mu_{\text{PUSCH}}$ : subcarrier spacing of UL BWP and of maximal SCS BWP | 3GPP TS 38.211, sec 5.3.2 | +| | prach-SubcarrierSpacing | $\mu_{\text{PRACH}}$ : subcarrier spacing of PRACH preamble | 3GPP TS 38.211, sec 5.3.2 | +| | prach-GuardbandOffset | $\bar{k}$ : guard offset from k1 (can be derived from the SCS for PRACH and PUSCH and PRACH format) | 3GPP TS 38.211, sec 6.3.3 | +| <b>Time Domain</b> | prach-StartSymbol | starting symbol | 3GPP TS 38.211, sec 6.3.3.2,<br>Tables 6.3.3.2-2 to 6.3.3.2-4 | +| | prach-Format | formats of the PRACH slot (0, 1, 2, 3, A1, ... A3/B3) | 3GPP TS 38.213, sec 9.2.2 | +| | numPRACH-Ocas | From $N_t^{\text{RA,slot}}$ : number of Time domain PRACH occasions within a PRACH slot | 3GPP TS 38.213, sec 9.2.2 | +| | cyclicPrefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation | 3GPP TS 38.211, sec 4.2, 5.3.1<br>3GPP TS 38.214, Table 5.1.2.1-1 | + +### 6.3.7 Beamforming + +In this release, the AAL\_UPLINK\_High-PHY profile supports the following beamforming methods available for OFH signaling: + +- Predefined-Beam Beamforming, as defined in section 10.4.2.1 of [8]; +- Weight-based Dynamic Beamforming, as defined in section 10.4.2.2 of [8]; +- Attribute-Based Dynamic Beamforming, as defined in section 10.4.3 of [8]; +- Channel-Information-Based Beamforming, as defined in section 10.4.4 of [8]. + +#### 6.3.7.1 Predefined-Beam Beamforming + +The AALI shall support the AAL Application signaling as described in section 6.2.7.1 + +#### 6.3.7.2 Weight-based Dynamic Beamforming + +The AALI shall support the AAL Application signaling of the following parameters, as needed for AAL\_UPLINK\_High-PHY profile signaling of beamforming weight vectors of (bfwI, bfwQ) in C-Plane Extensions 1, 11, 19 [8]: + +**Table 6.3.7.2-1: Weight-based Dynamic Beamforming Parameters for Uplink** + +| AAL-LPU Parameters | Summary | AAL-LPU Role | +|--------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| AAL-LPU → AAL Application | | | +| Channel Estimation Abstraction | A representation of SRS-based channel observations, as documented in the SRS channel model in section 6.3.5.2, e.g. for usage: codebook or usage: noncodebook | Signals an abstraction of the Channel Estimates to the AAL Application | +| AAL Application → AAL-LPU | | | +| mti [*] | Selected UEs for scheduling (for an illustration refer to the L users referenced in Appendix J.4 of [8]) | Compute combining weights for the selected UEs and Precoders, e.g. based on the reported Channel Estimation and its Abstraction.<br><br>Signal to O-RU beamforming vectors of weights (bfwI, bfwQ) over C-Plane for the AAL Application-selected UEs and Precoders | +| ul-TPMI | UE-based Precoder: selected precoding matrix for scheduling the UEs (see section 6.3.1.5 in of 3GPP TS 38.211) | | + +The High-PHY AAL API shall be extensible to allow, in future releases, the optional ability for the beamforming weights to be generated outside the AAL-LPU that consumes them for generating the appropriate C- and U-plane signaling by the accelerator, e.g. to generate the corresponding U-Plane eAxC I/Q sample streams and C-plane ueld field(s). + +#### 6.3.7.3 Attribute-Based Dynamic Beamforming + +The AALI shall support the AAL Application signaling as described in section 6.2.7.3 + +#### 6.3.7.4 Channel-Information-Based Beamforming + +The AALI shall support the AAL Application signaling of the following parameters, as needed for AAL-LPU-signaling of channel estimate vectors of (ciIsample, ciQsample) in C-Plane Section 6 [8]: + +**Table 6.3.7.4-1: Channel-Information-Based Beamforming Parameters for Downlink** + +| AAL-LPU Parameters | Summary | AAL-LPU Role | +|----------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------| +| AAL-LPU → AAL Application | | | +| [Channel Estimation Abstraction] | A representation of SRS-based channel observations, as documented in the SRS channel model in section 6.3.5.2, e.g. for usage: codebook or usage: noncodebook | Signals an abstraction of the Channel Estimation the AAL Application | +| AAL Application → AAL-LPU | | | +| mti | Selected UEs for scheduling (for an illustration refer to the L users referenced in Appendix J.4 of [8]) | Signal to O-RU the Channel Estimates for the AAL Application-selected UEs and Precoders | + +| | | | +|-----------------|-----------------------------------------------------------------------------------------------------|--| +| chosenLayers[*] | Per UE: Selected precoding matrix for scheduling the UEs (see section 6.3.1.5 in of 3GPP TS 38.211) | | +|-----------------|-----------------------------------------------------------------------------------------------------|--| + +1 + +2 + +# Annex A [informative] Stage-3 Support for AAL\_DOWNLINK\_High-PHY and AAL\_UPLINK\_High-PHY using FAPI + +This annex illustrates how SCF-222 [i.1] and SCF-223 [i.2] can be used to provide stage-3 support for the AAL\_DOWNLINK\_High-PHY and AAL\_UPLINK\_High-PHY profiles in this document. + +In particular: + +- Profile capabilities (sections 6.2.2 and 6.3.2) and Configurations (sections 6.2.2b and 6.3.2b) are supported via the SCF P5 interface +- Profile slot-level APIs (DL sections 6.2.3 – 6.2.7, UL sections 6.3.3 – 6.3.7) are supported via the SCF P7 interface +- Channel Models referenced in this document correspond to PDUs, which are transported over SCF P7 APIs in SCF-222 + +**NOTE:** + +- this illustration does not preclude other stage-3 implementations of the the stage-2 APIs referenced this document, nor does it preclude the addition of other features or extensions in the future. +- alignment of this document with non-O-RAN Alliance specifications is not required. + +An illustration of this stage-3 support is further illustrated below for mapping of the CSI-RS Channel Model parameters from section 6.2.5 to CSI-RS PDU and related parameters in SCF-222 [i.1] and SCF-223 [i.2]: + +| AAL-LPU Parameters | | Summary | SCF-222 [i.1] / SCF-223 [i.2]<br>Reference [i.1] | +|-------------------------------------------|--------------------|------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------| +| <b>Sequence Generation</b> | | | | +| $n_{\text{ID}}$ or $c_{\text{init}}[l]$ | | $n_{\text{ID}}$ : scrambling id<br>$c_{\text{init}}[l]$ : scrambling initialization for symb $[l]$ | <i>ScrambId</i> signals $n_{\text{ID}}$ | +| <b>Modulation</b> | | | | +| <acceleration based on hard-coded values> | | CSI-RS uses QPSK modulation | <QPSK>, implicit | +| <b>Precoding</b> | | | | +| <i>See section 6.2.7</i> | | Conceptually similar to FH signaling when precoding for Cat-B. 3GPP leaves DL precoding to implementation. | <i>Precoding and Beamforming</i><br><br>Attribute-based beamforming is supported in SCF-223 | +| <b>RE Mapping</b> | | | | +| Frequency Domain | $\mu, \mu_{\{0\}}$ | subcarrier spacing impacts waveform generation, including centering | <i>SubcarrierSpacing</i> signals $\mu$ | + +| | | | | +|--------------|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------| +| | | | The full set of numerologies, including $\mu_{\{0\}}$ is semistatically configured in P5 <i>dlFrequency</i> . | +| | startingRB | PRB where this CSI resource starts in relation to CRB#0 | <i>StartRB</i> signals startingRB | +| | nrofRBs | Number of PRBs across which this CSI resource spans. | <i>NrofRBs</i> signals nrofRBs | +| | Frequency Domain Allocation | Bitmap defining the frequencyDomainAllocation, with interpretation subject to the Row selection for table 7.4.1.5.3-1 | <i>FreqDomain</i> signals Frequency Domain Allocation | +| | CSI-RS locations Row | row indicating the CSI-RS location in table 7.4.1.5.3-1. Can be used to derive; <ul style="list-style-type: none"> <li>density <math>\rho</math> (see also Frequency Density)</li> <li>cdmType</li> <li>ports</li> <li><math>\bar{k}</math> in the <math>(\bar{k}, \bar{l})</math>-tuple</li> </ul> | <i>Row</i> signals CSI-RS locations Row | +| Time Domain | Density Dot5 Prb Location | Indicates whether even or odd PRBs are occupied by CSI-RS.<br><br>Applicable when density = dot5 (0.5) | <i>FreqDensity</i> signals Density Dot5 Prb Location | +| | CSI-RS locations Row | row indicating the CSI-RS location in table 7.4.1.5.3-1. Can be used to derive; <ul style="list-style-type: none"> <li><math>\bar{l}</math> in the <math>(\bar{k}, \bar{l})</math>-tuple</li> </ul> | <i>Row</i> signals CSI-RS locations Row | +| | l_0 | value of l_0 for the interpretation of table 7.4.1.5.3-1. Signaled by RRC parameter firstOFDMsymbolInTimeDomain | <i>SymbL0</i> signals l_0 | +| | l_1 | value of l_1 for the interpretation of table 7.4.1.5.3-1. Signaled by RRC parameter firstOFDMsymbolInTimeDomain2 | <i>SymbL1</i> signals l_1 | +| | Cyclic Prefix | Cyclic prefix type. Impacts time-domain allocation, including waveform generation | <i>CyclicPrefix</i> signals Cyclic Prefix | +| Power Offset | | | | +| | [Power offset w.r.t. SSS] | power offset with respect to SSS | <i>powerControlOffsetProfileNR</i> and <i>powerControlOffsetSSProfileNR</i> signal power offset via 3GPP look-up tables. | + +| | | | +|--|--|--------------------------------------------------------------------------------------------| +| | | <i>csiRsPowerOffsetProfileSSS</i> signals actual “Ratio of CSI-RS EPRE to SSS EPRE” [i.1]. | +|--|--|--------------------------------------------------------------------------------------------| + +1 + +2 + +# History + +| Date | Revision | Description | +|------------|----------|-----------------------------------------------------------------------------------------| +| 2024.12.10 | 07.00 | Addition of new parameters for LDPC decoding in PUSCH Data parameters (clause 6.3.3.2). | +| 2024.03.25 | 06.00 | Published from version 05.00.02 | +| 2023.03.17 | 05.00 | Published from version 04.00.02 | +| 2022.11.21 | 04.00 | Published from version 03.00.04 | +| 2022.07.29 | 03.00 | Published from version 02.00.03 | +| 2022.03.29 | 02.00 | Published from version 01.00.01 | +| 2021.11.15 | 01.00 | Published from version 00.00.12 | \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2fd5eaeff22262dc085e14adfdb0ad2472ac9dc2 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd2727019ae96e80efda4964e1a871737c2c73277a978726969f55d0e5275c2f +size 4536 diff --git a/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/51b4906b9379351e8b2aca58c4d6ee14_img.jpg b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/51b4906b9379351e8b2aca58c4d6ee14_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c5c6fd3ba38d7d3881c6836ab72c888b45162e8f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/51b4906b9379351e8b2aca58c4d6ee14_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e38483cbf6d1bdd04438a1570335a80b7de97cc9a175d47bbc542bb5456e4bb3 +size 4563 diff --git a/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3a71b98fcfc274b0603208cc5e23601d7fc924a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84a0e505aa8e8fcec39c03736b466858a7c1ef91abe309cdd2974ee18257e23b +size 4531 diff --git a/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/61484aa69fc23c81b4bf54a3b4523662_img.jpg b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/61484aa69fc23c81b4bf54a3b4523662_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0dafff0d143f0e9ac71c86669c7fc3b0682d85f2 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/61484aa69fc23c81b4bf54a3b4523662_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2ce00ae99e7e86228b7f130672ba510421677cf67ad0c7a2f81ad69fcee371be +size 4558 diff --git a/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/86a771f11fbc580d8fda7a877acd1c69_img.jpg b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/86a771f11fbc580d8fda7a877acd1c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82827af191c934857f3a5a97842fa19fb4aa5978 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/86a771f11fbc580d8fda7a877acd1c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54f690c723a011f67b244eeda5cca1f67e7a7784e122d72a637cea1ca968c8f4 +size 4531 diff --git a/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/raw.md b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..909d6b63896bcc0a65c62f43a9db522c75a61b1b --- /dev/null +++ b/marked/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01/raw.md @@ -0,0 +1,219 @@ + + +# --- **O-RAN Work Group 6 (Cloudification and Orchestration Workgroup)** + +## **Acceleration Abstraction Layer MUMIMO Precoder/BeamFormer Calculation Profile** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|--------------------------------------------------------------------------------------------|---| +| List of tables ..... | 3 | +| Foreword..... | 4 | +| Modal verbs terminology..... | 4 | +| Executive summary ..... | 4 | +| Introduction ..... | 4 | +| 1 Scope ..... | 5 | +| 2 References ..... | 5 | +| 2.1 Normative references ..... | 5 | +| 2.2 Informative references..... | 5 | +| 3 Definition of terms, symbols and abbreviations..... | 5 | +| 3.1 Terms..... | 5 | +| 3.2 Symbols..... | 6 | +| 3.3 Abbreviations ..... | 6 | +| 4 Overview ..... | 6 | +| 4.1 Purpose ..... | 6 | +| 4.2 Document Structure..... | 6 | +| 5 AAL Configuration and Management ..... | 6 | +| 6 AAL Profile Specifications ..... | 7 | +| 6.1 Introduction ..... | 7 | +| 6.2 Naming Conventions..... | 7 | +| 6.3 MUMIMO Precoder/BeamFormer Calculation Profile Specification ..... | 7 | +| 6.3.1 Introduction..... | 7 | +| 6.3.2 Profile Operation ..... | 7 | +| 6.3.3 MUMIMO Precoder/BeamFormer Calculation Profile Capabilities and Configurations ..... | 7 | +| 6.3.4 AAL Profile Specific Interface ..... | 8 | +| Annex (informative): Change History ..... | 9 | + +# --- List of tables + +| | | +|--------------------------------------------------------------------|---| +| Table 6.3.4-1: AAL Profile Parameters for Weight Calculation ..... | 7 | +|--------------------------------------------------------------------|---| + +# --- Foreword + +This Technical Specification (TS) has been produced by WG6 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- Executive summary + +This document provides the description of the requirements and stage-2 information models to implement an Acceleration Abstraction Layer (AAL) for the MUMIMO Precoder/BeamFormer Calculation functionality hosted by an AAL-LPU that is associated with an O-RAN Network Function. + +# --- Introduction + +This document specifies how to accelerate the functionality of an O-RAN network function where the MUMIMO Precoder/BeamFormer Calculation Acceleration Function (AF) is hosted on an AAL-LPU that is assigned to the AAL Application that is part of the O-RAN network function. This document also specifies a set of AAL Profiles and procedures for utilizing the AALI Common Management (AALI-C-Mgmt) and Application (AALI-C-App) interfaces to convey the information elements specified by the AAL Profiles. + +# --- 1 Scope + +The present document specifies the requirements and stage-2 information models for the MUMIMO Precoder/BeamFormer Calculation Profiles. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] Void +- [2] Void +- [3] Void +- [4] Void +- [5] Void +- [6] Void +- [7] O-RAN WG6 Acceleration Abstraction Layer General Aspects and Principles +- [8] O-RAN Acceleration Abstraction Layer High-PHY Profiles + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +Void + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations [given in [1] and the following] apply: + +| | | +|---------|--------------------------------------------------------| +| AAL | Acceleration Abstraction Layer | +| AALI | Acceleration Abstraction Layer interface | +| AAL-LPU | Acceleration Abstraction Layer Logical Processing Unit | +| BF | Beam Forming | +| CNF | Containerized Network Function | +| HWA | Hardware Accelerator | +| NF | Network Function | +| O-CU | O-RAN Centralized Unit | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| OS | Operating System | + +# --- 4 Overview + +## 4.1 Purpose + +The AAL General Aspects and Principles is described in [7] including a high-level architecture of the AAL and definition of the AAL profiles. This document details the AAL specification consisting of the description of the interface, information models, and requirements to implement an AALI for AAL\_MUMIMO\_PRECODER\_WEIGHTS\_CAL profile [7] + +The purpose of the AAL\_MUMIMO\_PRECODER\_WEIGHTS\_CAL profile is to support look-aside acceleration of beamforming (precoding) weight calculation by the Application. This profile compliments the High-PHY profiles specified in [8]. + +## 4.2 Document Structure + +This present document is structured as follows: Chapter 4 presents the overview and main purpose of this specification. Chapter 5 presents the high level AALI configuration and management principles for the AAL\_MUMIMO\_PRECODER\_WEIGHTS\_CAL profile. Chapter 6 presents the Profile Overview for the profile, sample capabilities, inputs, and outputs as well as HWA parameters for the profile. + +# --- 5 AAL Configuration and Management + +The AALI configuration and management APIs are the APIs that an Application (O-DU) executes to configure and manage the AAL-LPU(s) that have been allocated to the Application by the O-Cloud. The high-level Configuration and Management Principles are presented in [7]. + +# --- 6 AAL Profile Specifications + +## 6.1 Introduction + +Void + +## 6.2 Naming Conventions + +Void + +## 6.3 MUMIMO Precoder/BeamFormer Calculation Profile Specification + +### 6.3.1 Introduction + +The AAL\_MU MIMO\_PRECODER\_WEIGHTS\_CALC is used to support look-aside acceleration of beamforming (precoding) weight calculation by the Application + +### 6.3.2 Profile Operation + +The Application provides HWA (aka AF in [8]) with all the information required to calculate precoding weights, as shown in Table 6.3.4-1. HWA computes MU-MIMO precoding weights according to an implementation-specific method, one exemplary method being block diagonalization. + +HWA returns to the Application a handle\* (optional) to the precoding weights for the layers of the selected UEs together with precoding weights themselves. The precoding weights can be used by the Application to compute SINR per UE and per layer to assist with MCS selection. + +Application sends the precoding weights (optional) or handle (optional) to AF [8] via AAL\_DOWNLINK\_High-PHY Profile [8]. + +\*Handle represents an index to “Beamforming (precoding) weights per PRG for the layers of the selected UEs” uniquely. This is an optional parameter. It is introduced to enable following example implementation option: + +After precoding weights calculation, HWA stores the precoding weights locally together with the associated handle. HWA returns to Application the handle to the precoding weights as well as the precoding weights for the layers of the selected UEs. This provides option to Application to send just the handle to AF [8] in AAL\_DOWNLINK\_High-PHY Profile [8]. In this case, AF can use the handle to retrieve precoding weights stored locally. + +NOTE: This is applicable only for the scenario in which same HWA is used for “high Phy function” and “precoding weights calculation function”. + +### 6.3.3 MUMIMO Precoder/BeamFormer Calculation Profile Capabilities and Configurations + +#### 6.3.3.1 Summary of Capabilities + +Void + +#### 6.3.3.2 Summary of Configurations + +Void + +### 6.3.4 AAL Profile Specific Interface + +**Table 6.3.4-2 AAL Profile Parameters for Weight Calculation** + +| Parameters | Summary | HWA Role | +|---------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------| +| Application → HWA | | | +| UEs | Ordered list of UEs selected for scheduling | | +| Number of layers, per UE | Number of layers scheduled per UE | | +| Channel Estimation Abstraction | A representation of SRS-based channel observations, as documented in [7] (e.g. SVD, raw channel). Sent for each PRG and for each UE scheduled in the PRG. | Compute beamforming weights for the selected UEs and layers, e.g. based on block diagonalization based precoding. | +| HWA → Application | | | +| Beamforming (precoding) weights | Beamforming (precoding) weights per PRG for the layers of the selected UEs. | Compute precoding weights for the selected UEs and layers, e.g. based on the representation of SRS-based channel observations | +| Handle<br>(OPTIONAL) | Index to Beamforming (precoding) weights per PRG for the layers of the selected UEs. | | + +# --- Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.02.28 | 01.00.00 | AAL Profile specification to offload “MU-MIMO precoder/beamformer weights calculation” compute to Hardware Accelerator (HWA) in a look-aside manner. | +| 2024.07.15 | 01.00.01 | Delete unused citation from References section as per CR TEJA-2024.03.10-ORAN.WG6-D-CR-0001 | +| 2024.07.18 | 01.00.02 | Migrate the document to new O-RAN AAL-Profile template | +| 2024.07.31 | 01.01.00 | Final version for July '24 train, upgraded document revision to R004 | \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2fd5eaeff22262dc085e14adfdb0ad2472ac9dc2 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/0a255eef45f2d7cbdb4d95d6fbfe9784_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd2727019ae96e80efda4964e1a871737c2c73277a978726969f55d0e5275c2f +size 4536 diff --git a/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/6f5d9f3f3823b5950b5e1b8ab1385bd1_img.jpg b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/6f5d9f3f3823b5950b5e1b8ab1385bd1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bef7aa2635f47dbe2c59ab7b8deca200ce712f86 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/6f5d9f3f3823b5950b5e1b8ab1385bd1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bbe919c66bfc113129d0072693d088f1f0f076000872371e40064b5bb2f3e797 +size 86344 diff --git a/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82827af191c934857f3a5a97842fa19fb4aa5978 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/86a771f11fbc580d8fda7a877acd1c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54f690c723a011f67b244eeda5cca1f67e7a7784e122d72a637cea1ca968c8f4 +size 4531 diff --git a/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f9786619d9266ddf6962b7631fad8834bd583a3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/d13339fc4fc5df2fb6fe7ea7eed8a745_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:17a48c732b82959a70a4744afdf56099b05c77a70dfcfaa935549c6ab678bec2 +size 4509 diff --git a/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7423b16589e846f2b16ec9a44a377d2efd9a9090 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/e9507bda9a6436b03829c6450b7b29ac_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b000e2a5c716ba0590040bc3dc3321438d999e8b057249129751dff05131f8c +size 4564 diff --git a/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/raw.md b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..b20bdc133c6610cb8173449ae9b9778bfa13a2ac --- /dev/null +++ b/marked/WG6/O-RAN.WG6.ASD-R003-v01.00/raw.md @@ -0,0 +1,324 @@ + + +# --- **O-RAN Work Group 6****Application Service Descriptor specification** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|-----------------------------------------------------------------------|-----------| +| List of figures ..... | 3 | +| List of tables ..... | 3 | +| Foreword..... | 4 | +| Modal verbs terminology ..... | 4 | +| 1 Scope ..... | 5 | +| 2 References ..... | 5 | +| 2.1 Normative references ..... | 5 | +| 2.2 Informative references ..... | 5 | +| 3 Definition of terms, symbols and abbreviations ..... | 5 | +| 3.1 Terms ..... | 5 | +| 3.2 Symbols..... | 6 | +| 3.3 Abbreviations ..... | 6 | +| 4 Objective ..... | 6 | +| 5 Conventions..... | 6 | +| 6 Application Service Descriptor information elements ..... | 7 | +| 6.1 Overview ..... | 7 | +| 6.2 Application Service Descriptor Information Element ..... | 8 | +| 6.3 Deployment Item (DeploymentItem) Information Element ..... | 9 | +| 6.4 External connection point (ExtCpd) Information Element ..... | 10 | +| 6.5 NetworkInterfaceRealizationRequirements Information Element ..... | 10 | +| 6.6 ExtCpdParamMappings Information Element..... | 13 | +| 6.7 EnhancedClusterCapabilities Information Element..... | 14 | +| <b>Annex (informative): Change History .....</b> | <b>16</b> | + +# --- List of figures + +| | | +|------------------------------------------------------------------|---| +| Figure 6.1-1: DeploymentDescriptor with ASD representation ..... | 8 | +|------------------------------------------------------------------|---| + +# --- List of tables + +| | | +|-------------------------------------------------------------|----| +| Table 6.2-1: ASD Information Model ..... | 8 | +| Table 6.3-1: DeploymentItem IE ..... | 9 | +| Table 6.4-1: ExtCpd IE ..... | 10 | +| Table 6.5-1 NetworkInterfaceRealizationRequirements IE..... | 10 | +| Table 6.6-1: ExtCpdParamMappings IE..... | 13 | +| Table 6.7-1: EnhancedClusterCapabilities IE..... | 14 | + +# --- Foreword + +This Technical Specification (TS) has been produced by WG6 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +# --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the structure and format of the Application Service Descriptor (ASD). + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] Kubernetes label key-value-nomenclature <https://kubernetes.io/docs/concepts/overview/working-with-objects/labels/> +- [2] O-RAN-WG6.ORCH-USE-CASES-R003: “Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN”. + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] O-RAN.WG6.AppLCM-Deployment-R003-v01.00: “Application Life Cycle Management (LCM) for Deployment Technical Recommendation”. +- [i.2] O-RAN.WG10.OAM-Architecture-R003: “O-RAN Operations and Maintenance Architecture”. +- [i.3] Kubernetes node features <https://kubernetes-sigs.github.io/node-feature-discovery/stable/get-started/index.html> + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms given in [2] apply. + +## 3.2 Symbols + +Void. + +## 3.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply: + +| | | +|--------|----------------------------------------------| +| ASD | Application Service Descriptor | +| CNI | Container Network Interface | +| DC | Data Center | +| DPDK | Data Plane Development Kit | +| GARP | Gratuitous ARP (Address Resolution Protocol) | +| GPU | Graphics Processing Unit | +| IPAM | IP Address Management | +| K8s | Kubernetes | +| LAG | Link Aggregation Group | +| LI | Lawful Interception | +| MAC | Media Access Control | +| NAD | Network Attachment Definition | +| NF | Network Function | +| NW | Network | +| OAM | Operations, Administration and Management | +| O-RAN | Open Radio Access Network | +| OVS | Open vSwitch | +| PCIe | Peripheral Component Interconnect Express | +| PF | Physical Function | +| SMO | Service Management and Orchestration | +| SR-IOV | Single Root I/O Virtualization | +| URI | Uniform Resource Identifier | +| UUID | Universally Unique Identifier | +| VLAN | Virtual Local Area Network | +| VF | Virtual Function | +| vNIC | virtual Network Interface Card | +| VPN | Virtual Private Network | +| VPP | Vector Packet Processing | + +# --- 4 Objective + +The present document delivers a specification of the information elements and attributes applicable to the ASD. + +# --- 5 Conventions + +The attributes of the ASD information elements are described in the tables provided in section 6.2. Each table has 5 columns, with the following significance: + +- The "Attribute" column provides the attribute name. +- The "Qualifier" column indicates whether the support of the attribute is mandatory, optional or conditional from the SMO perspective. +- The "Cardinality" column contains the minimum and maximum cardinality of this information element (e.g., 1, 0 ... N, 1 ... N). A cardinality range starting with 0 indicates that the attribute need not always be included and 1 indicates that the attribute needs to be always included. +- The "Type" column provides information on the type of the attribute values. It can be the name of an Information Element. If a cell in the "Type" is marked as "Not specified", which indicates that the specification of the type is left to the data model. +- The "Description" provides a brief explanatory description, additional constraints, and examples. + +# 6 Application Service Descriptor information elements + +## 6.1 Overview + +The Application Service Descriptor (ASD) contains data that describes an application and that is used by the SMO as input for the deployment of the application workload. + +The ASD is a complementary descriptor to the cloud-native deployment artifacts. Hence, it contains design-time information provided by the application vendor that is not described/available in the cloud native artifacts. Such complementary information in the ASD can include specific infrastructure capabilities requirements for the deployment of the application software workload, constraints on the Kernel type needed, additional networking requirements needed beyond primary connectivity described in the cloud native artifacts, any special CNI (Container Network Interfaces), etc [i.1]. + +ASD can support an application workload deployment on OS container infrastructures, and it is applicable to O-RAN NF Deployments, xApps, and rApps. + +Figure 6.1-1 illustrates the representation of O-RAN OAM Application Packaging Model as depicted in version 10.00 of [i.2] and shows how the Application Service Descriptor is positioned within the Application Package Model. + +![Figure 6.1-1: DeploymentDescriptor with ASD representation. The diagram shows a hierarchical structure of artifacts. On the left, a vertical flow shows 'ASD (DeploymentDescriptor)' having 'ASD DeploymentItem (DeploymentItem)', which has a 'Helm Chart (CloudNative DescriptorFile)', which may have a 'DockerImage (ExecutableImage)'. These are grouped in a dashed box labeled 'Deployment related artifacts'. On the right, a more complex graph shows 'AppPackage' at the top, which has 'DeploymentDescriptor' and 'MLModelDescriptor'. 'DeploymentDescriptor' has 'DeploymentItem', which has 'CloudNativeDescriptorFile' and 'ExecutableImage'. 'MLModelDescriptor' has 'ComponentDescriptor', which has 'ManagementDescriptor'. 'ManagementDescriptor' has 'SecurityDescriptor', 'AlarmDictionary', 'ConfigurationModel', 'AccountingDictionary', and 'PerformanceDictionary'. 'ComponentDescriptor' also has 'PTEDescriptor'.](6f5d9f3f3823b5950b5e1b8ab1385bd1_img.jpg) + +Figure 6.1-1: DeploymentDescriptor with ASD representation. The diagram shows a hierarchical structure of artifacts. On the left, a vertical flow shows 'ASD (DeploymentDescriptor)' having 'ASD DeploymentItem (DeploymentItem)', which has a 'Helm Chart (CloudNative DescriptorFile)', which may have a 'DockerImage (ExecutableImage)'. These are grouped in a dashed box labeled 'Deployment related artifacts'. On the right, a more complex graph shows 'AppPackage' at the top, which has 'DeploymentDescriptor' and 'MLModelDescriptor'. 'DeploymentDescriptor' has 'DeploymentItem', which has 'CloudNativeDescriptorFile' and 'ExecutableImage'. 'MLModelDescriptor' has 'ComponentDescriptor', which has 'ManagementDescriptor'. 'ManagementDescriptor' has 'SecurityDescriptor', 'AlarmDictionary', 'ConfigurationModel', 'AccountingDictionary', and 'PerformanceDictionary'. 'ComponentDescriptor' also has 'PTEDescriptor'. + +Figure 6.1-1: DeploymentDescriptor with ASD representation + +## 6.2 Application Service Descriptor Information Element + +For the O-RAN NF Deployments the Application Service Descriptor (ASD) is a main top level descriptor template which consists of the attributes described in Table 6.2-1 below. + +Table 6.2-1: ASD Information Model + +| Attribute | Qualifier | Cardinality | Type | Description | +|-----------------------|-----------|-------------|--------|--------------------------------------------------------------------------------------------------------------------------------------------------------| +| asdId | M | 1 | String | Identifier of this ASD information element. This attribute shall be globally unique. The format will be defined in the data model specification phase. | +| asdVersion | M | 1 | String | Identifies the version of the ASD | +| asdSchemaVersion | M | 1 | String | Specifies the version of the ASD's schema. See note 1. | +| asdProvider | M | 1 | String | Provider of the application and of the ASD. | +| asdApplicationName | M | 1 | String | Name to identify the application. Invariant for the application lifetime. | +| asdApplicationVersion | M | 1 | String | Specifies the version of the application. See note 2. | + +| Attribute | Qualifier | Cardinality | Type | Description | +|---------------------------------------------------------------------------------|-----------|-------------|-----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| asdApplicationInfoName | M | 0..1 | String | Human readable name for the application. Can change during the ASD lifetime. | +| asdInfoDescription | M | 0..1 | String | Human readable description of the application. Can change during the ASD lifetime. | +| asdExtCpd | M | 0..N | ExtCpd | Describes the externally exposed connection points of the application. | +| enhancedClusterCapabilities | M | 0..1 | EnhancedClusterCapabilities | A list of expected capabilities of the target deployment cluster to aid placement of the application on a suitable cluster. | +| deploymentItem | M | 1..N | DeploymentItem | Cloud native deployment artifacts associated with the application. | +| asdInvariantId | M | 1 | String | Identifier of this descriptor in a version independent manner. This attribute is invariant across versions of ASD. It is in UUID format as specified in RFC 4122 | +| NOTE 1: Version changes when a change is made to any one of the ASD attributes. | | | | | +| NOTE 2: Version changes when software or ASD values changes | | | | | + +## 6.3 Deployment Item (DeploymentItem) Information Element + +The deploymentItem defined in O-RAN Operations and Maintenance Architecture [i.2] is realized by the DeploymentItem IE which has the DeploymentItem structure described in Table 6.3-1 below. + +The DeploymentItem IE describes the type of cloud native artifact, its order of deployment in case multiple cloud native artifacts are employed with the same ASD, and the list of parameters that can be parameterized in this cloud native deployment artifact at deployment time. + +**Table 6.3-1: DeploymentItem IE** + +| Attribute | Qualifier | Cardinality | Type | Description | +|--------------------|-----------|-------------|---------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| deploymentItemId | M | 1 | String | The identifier of this deployment item | +| artifactType | M | 1 | String | Specifies the artifact type. One of following values can be chosen: "helm_chart", "helmfile", "crd", "terraform". | +| artifactId | M | 1 | String | Unique reference to a deployment item (cloud native deployment artifact). It can be a URI or file path. | +| deploymentOrder | M | 0..1 | Integer | Specifies the deployment order of the deployment item. A lower value specifies that the deployment item belongs to an earlier deployment stage, i.e., needs to be installed prior to a deployment item with higher deploymentOrder values. If not specified, the deployment of the deployment item can be done in arbitrary order and decided by the SMO. | +| lifecycleParameter | M | 0..N | String | The list of parameters that can be overridden at deployment time (e.g., the list of parameters in the values.yaml which can be overridden at deployment time) | + +## 6.4 External connection point (ExtCpd) Information Element + +The ExtCpd IE describes endpoints exposed by the application to enable orchestrators to string together or optimally place linked applications. + +**Table 6.4-1: ExtCpd IE** + +| Attribute | Qualifier | Cardinality | Content | Description | +|-------------------------------------------------------------------------------------|-----------|-------------|-----------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| id | M | 1 | String | The identifier of this ExtCpdData | +| description | M | 1 | String | Describes the service exposed. | +| virtualLinkRequirement | M | 1 | String | Refers in an abstract way to the network that the ExtCpd shall be exposed for (for example, OAM, EndUser, backhaul, LI, etc). The intent is to enable a network operator to identify which extCpd was designed to be connected to which VPN. | +| networkInterfaceRealizationRequirements | M | 0..1 | NetworkInterfaceRealizationRequirements | Details container implementation specific requirements on the NetworkAttachmentDefinition. See notes 1 and 2. | +| inputParamMappings | M | 0..1 | ExtCpd.ParamMappings | Information on what parameters are required to be provided to the deployment tools for the asdExtCpd instance. | +| resourceMapping | M | 0..1 | String | Resource name for the cloud native resource manifest, as specified in the cloud native descriptor declaring the network interface (e.g., in the helm chart, for the: service, ingress or pod resource). Enables, together with knowledge on namespace, the SMO to lookup the runtime data related to the extCpd. | +| NOTE 1: Applies only for ExtCpd representing secondary network interfaces in a POD. | | | | | +| NOTE 2: Several ExtCpd may refer to same additional network interface requirements. | | | | | + +## 6.5 NetworkInterfaceRealizationRequirements Information Element + +The NetworkInterfaceRealizationRequirements IE describes details related to secondary networks that attach the OS containers to the logical or physical networks. + +**Table 6.5-1 NetworkInterfaceRealizationRequirements IE** + +| Attribute | Qualifier | Cardinality | Content | Description | +|-----------|-----------|-------------|---------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| trunkMode | M | 0..1 | Boolean | <p>Specifies whether the interface is capable of carrying traffic for multiple VLANs.</p> <p>If not present or set to false: this interface shall connect to single network.</p> <p>If set to true: the network interface shall be a trunk interface (connects to multiple VLANs).</p> | + +| Attribute | Qualifier | Cardinality | Content | Description | +|---------------|-----------|-------------|---------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| ipam | M | 0..1 | Enum | <p>Specifies which mode is used for the IP address assignment.</p> <p>Values:</p> <ul style="list-style-type: none"> <li>"infraProvided": the CNI specifies how IPAM is done and assigns the IP address to the pod interface.</li> <li>"orchestrated": the IP address to be assigned to the pod interface is expected from the orchestration function as input parameter to the deployment request.</li> <li>"userManaged": the IP address is provided directly to the application via an external management entity.</li> </ul> <p>Default value is "infraProvided".</p> | +| interfaceType | M | 0..1 | Enum | <p>Specifies the type of network interface. Different types of interfaces are supported by different CNIs.</p> <p>Values:</p> <ul style="list-style-type: none"> <li>"kernel.netdev": Linux kernel or vSwitch based. It is supported by CNIs™ like: OVS, MACVLAN, IPVLAN, BRIDGE, PTP, etc.</li> <li>"direct.userspace": Provides direct access to network PCIe, typically an SR-IOV VF, but could also be a PF. Uses application specific driver contained in the image. The device is bound to a driver by the cloud provider which supports user space control by the application (e.g. vfio_pci, igb_uio). It is supported by the following CNIs™: SRIOV, HOST-DEVICE.</li> <li>"direct.kerneldriver": Similar to direct.userspace but device is bound to a kernel driver by the cloud provider and can be consumed in the same way as a kernel netdev. It is supported by the following CNIs™: SRIOV, HOST-DEVICE.</li> <li>"direct.bond": Based on the BOND CNI™. Requires the existence of a mated pair of direct kernel network attachments prior to the creation of the bond. Thus, when this interface type is indicated, three attachments definitions to the secondary container cluster network are expected: two providing the direct</li> </ul> | + +| Attribute | Qualifier | Cardinality | Content | Description | +|---------------------|-----------|-------------|---------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | <p>kerneldriver functionality and one with the BOND CNI™</p> <ul style="list-style-type: none"> <li>"userspace": Based on the userspace CNI™ requires infrastructure to support a DPDK-OVS or VPP based vSwitch.</li> </ul> <p>Default value is "kernel.netdev".</p> | +| interfaceOption | M | 0..N | Enum | <p>vNIC configurations the network interface is verified to work with.</p> <p>This attribute is applicable for interfaces of type "userspace".</p> <p>Values:</p> <ul style="list-style-type: none"> <li>"virtio"</li> <li>"memif"</li> </ul> | +| interfaceRedundancy | M | 0..1 | Enum | <p>Method required from the infrastructure to provide redundancy for the interface.</p> <p>Values:<br/>"infraProvided", "left", "right",<br/>"activeActiveBond", "activePassiveBond",<br/>"activePassive13"</p> <ul style="list-style-type: none"> <li>"infraProvided": The application sees one vNIC, but the infrastructure provides redundant access to the network via both switch planes. For interface of type kernel.netdev the redundancy is provided by the vSwitch or Linux bonding. For interfaces of type direct, it requires that the physical NIC is connected to both switch planes (a.k.a. smartNIC). Thus, it imposes hardware requirements on the infrastructure. For interface of type userspace redundancy handled by a DPDK-OVS or VPP vSwitch</li> <li>"left" and "right": indicates a vNIC connected non-redundantly to the network via one specific (left or right) switchplane. Redundancy is implemented by having two external connection points, indicating different values (left/right) in the descriptor.</li> </ul> <p>For the the following values, the infrastructure provides for a single external connection point a mated vNIC pair in the Pod, one connecting to the network via left switchplane and the other connecting to the network via the right switchplane, and with the application using them together as a redundant</p> | + +| Attribute | Qualifier | Cardinality | Content | Description | +|-----------|-----------|-------------|---------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | | <p>network interface using a particular redundancy method that need to be accomodated in the node infrastructure:</p> <ul style="list-style-type: none"> <li>• "activeActiveBond": Requires a static multi-chassis LAG in active-active mode from the infrastructure. Typically corresponds to bonding mode-2 "balance-xor"</li> <li>• "activePassiveBond": The interfaces are bonded in active-passive mode in the application with move of bond MAC address. No specific requirements on DC fabric. Typically corresponds to bonding mode-1 "active-backup"</li> <li>• "activePassive13": Application moves its IP address by attaching it to one of the two MACs by use of GARP messages.</li> </ul> | + +## 6.6 ExtCpdParamMappings Information Element + +The ExtCpdParamMappings IE describes required information on what parameters to be provided to the deployment tools for the ExtCpd instance. + +**Table 6.6-1: ExtCpdParamMappings IE** + +| Attribute | Qualifier | Cardinality | Content | Description | +|----------------|-----------|-------------|---------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| loadbalancerIP | M | 0..1 | String | When present, this attribute specifies the name of the deployment artifact input parameter through which the SMO can configure the loadbalancerIP parameter of the K8s service or ingress controller that the ExtCpd represents. See note 2. | +| externalIPs | M | 0..1 | String | When present, this attribute specifies the name of the deployment artifact input parameter through which the SMO can configure the externalIPs parameter of the K8s service or ingress controller, or the pod network interface annotation, that the ExtCpd represents. The param name and provided IP address(es) value will be passed to the deployment tool when deploying the DeploymentArtifacts. See note 2. | +| nadName | M | 0..N | String | These attributes specify, for an ExtCpd representing a secondary network interface, the name(s) of the deployment artifact input parameter(s) through which the SMO can provide the names of the network attachment definitions (NADs) the SMO has created as base for the network interface the ExtCpd represents.<br>It is expected that the NADs themselves have been created prior to the deployment of the deployment artifacts. See notes 1, 2, and 3. | +| nadNamespace | M | 0..1 | String | Specifies, for an ExtCpd representing a secondary network interface, the name of the deployment artifact input parameter through which the SMO can provide the namespace where the NADs are located. | + +| Attribute | Qualifier | Cardinality | Content | Description | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------|-------------|---------|---------------------------------------------------------------------------------------------| +| | | | | Attribute may be omitted if the namespace is same as the application namespace. See note 2. | +| <p>NOTE 1: When the ExtCpd represent a networkRedundant/mated pair of sriov interfaces, there are references to 2 or 3 related NADs needed to be passed, while for other interface types only one NAD reference is needed to be passed.</p> <p>NOTE 2: The format of the Content strings is specific for each different orchestration templating technology used (Helm, Teraform, etc.). Currently only a format for use with Helm charts is suggested: "<helmchartname>:[<subchartname>.] 0 ... N[<parentparamname>.] 0 ... N<paramname>". Whether the optional parts of the format are present depends on how the parameter is declared in the helm chart. An example is: "chartName:subChart1.subChart2.subChart3.Parent1.Parent2.Parent3.parameter".</p> <p>NOTE 3: A direct attached (passthrough) network interface, such as an sriov interface, attaches to a network via only one of the two switch planes in the infrastructure.</p> <p>When using a direct attached network interface one therefore commonly in a pod uses a mated pair of sriov network attachments, where each interface attaches same network but via different switchplane.</p> <p>The application uses the mated pair of network interfaces as a single logical “swith-path-redundant” network interface – and this is represented by a single ExtCpd.</p> <p>Also, there is a case where a third “bond” attachment interface is used in the pod, bonding the two direct interfaces so that the application does not need to handle the redundancy issues – application just uses the bond interface.</p> <p>In this case all three attachments are together making up a logical “switch-path-redundant” network interface represented by a single ExtCpd. When three NADs are used in the ExtCpd the NAD implementing the bond attachment interface is provided through the parameter indicated in the third place in the nadNames attribute.</p> | | | | | + +## 6.7 EnhancedClusterCapabilities Information Element + +The EnhancedClusterCapabilities IE describes information which is used to aid placement of the application service on a suitable cluster. + +**Table 6.7-1: EnhancedClusterCapabilities IE** + +| Attribute | Qualifier | Cardinality | Content | Description | +|-------------------------|-----------|-------------|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| minKernelVersion | M | 1 | String | Describes the minimal required Kernel version, e.g., 4.15.0. Coded as displayed by linux command uname -r | +| requiredKernelModule | M | 0..N | String | Required kernel modules are coded as listed by linux lsmod command, e.g., ip6_tables, cryptd, nf_nat etc. | +| conflictingKernelModule | M | 0..N | String | Kernel modules, which shall not be present in the target environment. The kernel modules are coded as listed by linux lsmod command, e.g., ip6_tables, cryptd, nf_nat etc. Example: Linux kernel SCTP module, which may conflict with use of proprietary user space SCTP stack provided by the application. | +| requiredCustomResource | M | 0..N | Structure (inlined) | <p>List of the required custom resource types in the target environment, identifying each by the "kind" and "apiVersion" field in the K8S resource manifests and in the application. The list shall include those custom resource types which are not delivered with the application.</p> <p>Example:<br/>requiredCustomResources:<br/>- {kind: "Redis", apiVersion: "<a href="#">kubedb.com/v1alpha1</a>"}</p> | +| >kind | M | 1 | String | Kind of the custom resource | + +| Attribute | Qualifier | Cardinality | Content | Description | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------|-------------|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| >apiVersion | M | 0..1 | String | apiVersion of the custom resource. If not indicated, any apiVersion of the custom resource is valid. | +| clusterLabel | M | 0..N | String | <p>This attribute indicates the required O-Cloud Node Cluster capabilities.</p> <p>These can indicate special infrastructure capabilities (e.g., NW acceleration, GPU compute, etc.). The intent of these O-Cloud Node Cluster capabilities is to serve as a set of values that can support the SMO in application placement decisions. See note 1.</p> <p>clusterLabel follow the Kubernetes label key-value-nomenclature [1] .</p> <p>This attribute should use the standardized values for the O-RAN O-Cloud Node Cluster capabilities, the existing values for node features [i.3], and any new capabilities identified in O-RAN specifications. The attribute supports also extensions for non standardized values. See note 2.</p> | +| requiredPlugin | M | 0..N | Structure (inlined) | A list of the names and versions of the required K8s plugin (e.g., multus v3.8) | +| >requiredPluginName | M | 1 | String | The names of the required K8s plugin (e.g., multus) | +| >requiredPluginVersion | M | 0..1 | String | The version of the required plugin (e.g., 3.8). If not indicated, any version of the plugin is valid. | +| <p>NOTE 1: The SMO uses the set of standardized capabilities to identify O-Cloud Node cluster capabilities required in the DeploymentDescriptors and to match them to the capabilities available in the O-Cloud.</p> <p>NOTE 2: References to standandardized values for the O-RAN O-Cloud Node Cluster capabilities and/or new capabilities identified in O-RAN specifications will be added in future versions of the present document.</p> | | | | | + +# Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.04.17 | 00.00.01 | Initial TS skeleton | +| | 00.00.02 | Editor's notes with references to clauses in O-RAN.WG6.AppLCM-Deployment-R003-v01.00 for content, and informative document reference added. | +| 2023.08.23 | 00.00.03 | Implemented CRs:<br>NOK-2023.06.07-WG6-CR-ASD_conventions (NOK-0054 rev 1)<br>NOK-2023.06.07-WG6-CR-ASD_overview-02 (NOK-0055 rev 2) | +| 2023.09.07 | 00.00.04 | Implemented CRs:<br>NOK-2023.06.07-WG6-CR-ASD_application_service_descriptor_clauses-v05 (NOK-0056 rev 5)<br>ERI-2023.06.14-WG6-CR-0015-NetworkInterfaceRealizationRequirements-v03 (ERI-0015 rev 3) | +| 2023.10.27 | 00.00.05 | Implemented CRs:<br>ERI-2023.09.26-WG6-CR-0019-ASD-corrections-v04<br>ERI-2023.10.04-WG6-CR-0020-ASD-empty-clauses-and-cleanup-v02 | +| 2023.11.07 | 00.00.06 | Copyright changed to 2024 | +| 2023.11.15 | 00.00.07 | Addresses comments from Thinh at<br><a href="#">November 2023 WG Approval Comment Wiki - Cloudification and Orchestration Workgroup - Confluence (atlassian.net)</a><br><br>Implements three changes from ERI-2023.09.26-WG6-CR-0019-ASD-corrections-v04 that were missed when implementing the CR in v.00.00.05. | +| 2023.11.21 | 00.00.08 | Addresses comments from Joan at<br><a href="#">November 2023 WG Approval Comment Wiki - Cloudification and Orchestration Workgroup - Confluence (atlassian.net)</a> | +| 2023.11.21 | 00.00.09 | Final resolution of Joan's comments according to agreement in WG6 meeting on 2023.11.21.<br><a href="#">November 2023 WG Approval Comment Wiki - Cloudification and Orchestration Workgroup - Confluence (atlassian.net)</a> | +| | 01.00 | Final version 01.00 | +| | | | \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/00cd1d2c88add94d3a71d753784c4d9f_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/00cd1d2c88add94d3a71d753784c4d9f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..587dcd18e616bcea7777872700c28885000f4c78 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/00cd1d2c88add94d3a71d753784c4d9f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f2d5c015dcf16099df6757e220245be6443dcabb74b79a2f40431c85261bceea +size 56375 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/032b1a37d2cfee141dacddefb4d3ad3b_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/032b1a37d2cfee141dacddefb4d3ad3b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4802c7398521ff0a063f5e71f54a1c6691a45b0f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/032b1a37d2cfee141dacddefb4d3ad3b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4bf60d09d6e70c8f0771f563fb1829c16d2f825654b9e030d71afa0379687679 +size 47643 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/17e5e622f4efba5964f994613412499a_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/17e5e622f4efba5964f994613412499a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25144d08eab6644442f26046b1224b6d2e86409d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/17e5e622f4efba5964f994613412499a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f81625a6f0a96639ce72d62904bc8ee89f47e91982f377eaf7c7ceeba8ff006e +size 28257 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/2316693227d23dbe64b1b40a4f608857_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/2316693227d23dbe64b1b40a4f608857_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddf0df57794ea9b8ecae37fdb780093612c73cf1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/2316693227d23dbe64b1b40a4f608857_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f93b730555265385948a4c0b8860d60612bd5f0313c604be06af0244c74c8928 +size 51111 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/23f9a125c64b34a81f0d4f75fc63e164_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/23f9a125c64b34a81f0d4f75fc63e164_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d4090f7ee7758aeedbd569d0e4061c0f8b090a8f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/23f9a125c64b34a81f0d4f75fc63e164_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8a4032109567f7c4d17462dd6a052fad74145737f84bc3358c7ea074387952df +size 95317 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/290512c08ab250f40a7703cb22936341_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/290512c08ab250f40a7703cb22936341_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..036f52c67f22704a2034d90ec057aa1e83ec0467 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/290512c08ab250f40a7703cb22936341_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3e723373107636ec7b1c798fa2412972791ca2029d089cbdca47ac8a904d3a3f +size 33797 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/2aca22ae3dcc130118027fc1882e6b34_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/2aca22ae3dcc130118027fc1882e6b34_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d6657a6032c001f577a15bea84fcde7c8dcdbc8 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/2aca22ae3dcc130118027fc1882e6b34_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:771cfb96480e208c7feaff85adde9d9a3f5656a403c5b3c25b25b1cfa48e54c8 +size 34037 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/2d059d72a2f290f3e44ab2da20633fc7_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/2d059d72a2f290f3e44ab2da20633fc7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f1aa270912378d02734c24d60148bc0e56be9962 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/2d059d72a2f290f3e44ab2da20633fc7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0c796df50eaa0bd392929c886966bf7acc37283157f6d98900d591ad2d57ee4a +size 2954 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/338e65a06e4e9d8d1d7acdaa59bbb3bf_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/338e65a06e4e9d8d1d7acdaa59bbb3bf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..634efa38b10032c461c9da181897909acf3f3b0a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/338e65a06e4e9d8d1d7acdaa59bbb3bf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:68f17e619626c24798227654ccf3521bc65805a0a409efadfff1111eceefcdd2 +size 13822 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/37e6d0b0d8dfea7db6a15681f108d7a5_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/37e6d0b0d8dfea7db6a15681f108d7a5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..32f6310adb56cf7dc8006f325cae57ea035d950e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/37e6d0b0d8dfea7db6a15681f108d7a5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d835320c6de0c50a95d1a7391166997d411b41d43b9d57132029a1454e4db632 +size 54186 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/41ebba9617dff91ac8d3573c71d5dab8_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/41ebba9617dff91ac8d3573c71d5dab8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..06376ecd8bd4637d0d6296b6782d41686f77ae76 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/41ebba9617dff91ac8d3573c71d5dab8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7bffd33ce0a43ffa098284cd9fa97a018bba20773ef4da0a6a7626cd83cc1dba +size 44239 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/4ca75796e11673fd1833bdf9d6b14bdf_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/4ca75796e11673fd1833bdf9d6b14bdf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..07bc232c4fd70e3b1c4e53f8e43243dd792fa6e7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/4ca75796e11673fd1833bdf9d6b14bdf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:098d4653b9a75148d4840f0ce4d7222d3e777471403c0d312d9030af75a48bef +size 55161 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/4d74c292e5727a2f1e3ff37a2b42f46b_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/4d74c292e5727a2f1e3ff37a2b42f46b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..97691624f39c507014d488c81184c54dd0cdecfe --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/4d74c292e5727a2f1e3ff37a2b42f46b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:20f626aa2d9e6639ce008a1659c8d11572b801866438b9e0878af4aacbd4408f +size 55827 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/52e9b22241c70801c875a329c2dbc785_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/52e9b22241c70801c875a329c2dbc785_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8eb1e9be1d2d22d4cebd691df0f6410f5f86bc6d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/52e9b22241c70801c875a329c2dbc785_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3df9c13d506b7ed0dc788f3bf97c18e0b87c13004b6d7864372796fa83201663 +size 26061 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/5394308b82aa861cc21518d87177972a_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/5394308b82aa861cc21518d87177972a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..af06e01b6e66d6a35a334df3fcd88b79f60fc58c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/5394308b82aa861cc21518d87177972a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3e5f5e8bac1c1f1e091372a0ca51fbfcc5ff5672d6ef5b22dc9d356bea365e54 +size 23036 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/55fd92ea1b3773552894f94e4791aa66_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/55fd92ea1b3773552894f94e4791aa66_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..793f2467aa62eb58ea7a49957b0ea63945e7aa4b --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/55fd92ea1b3773552894f94e4791aa66_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5c21d85aa92e26632984ca93581603c52b5621c01db0720aaa9ae84067507525 +size 47989 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/5a6aa3d4c32c769ddb4ee66caad69b08_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/5a6aa3d4c32c769ddb4ee66caad69b08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8c46f17eeb01d37f6f85dc73909de2b09dc4736d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/5a6aa3d4c32c769ddb4ee66caad69b08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4edd36a89c0533606eb55838e3f8bcb10433f6970d3b0fcc679230d6a5e256cb +size 51059 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/6200e43fb3139bbc5f2e5bbdee5c333b_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/6200e43fb3139bbc5f2e5bbdee5c333b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7eb2174222ccbcd80068938bdaf81467cbdac383 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/6200e43fb3139bbc5f2e5bbdee5c333b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:085fb9fb6b3a4e0ba915a92dd4e9c17db9146e83cd6143ca92f0cc83a6a74161 +size 150779 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/673c0b4d6f9f9b55b55bd0f71962c1ee_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/673c0b4d6f9f9b55b55bd0f71962c1ee_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..021805d00cbe8efe7ba3aaad79d8fd08cb073809 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/673c0b4d6f9f9b55b55bd0f71962c1ee_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84273412f76f951e459b0a83349e923a9a7c8b2259269331b1100b75384891b3 +size 39582 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/696fcdb6c0a6a69d1e75488f9b0f8eef_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/696fcdb6c0a6a69d1e75488f9b0f8eef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..945b9aedfe98d3188dbac37e2e8947d1e9616933 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/696fcdb6c0a6a69d1e75488f9b0f8eef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:57ab9fc73e95886feb1847ec9de1bae80d476e6fcac74e52391e89bf50b84430 +size 47313 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/71e995dbebfdb3f543d6734fbcc4b2b0_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/71e995dbebfdb3f543d6734fbcc4b2b0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..003ab12f47e2270e2e8a4cd0410d05f6779bae1f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/71e995dbebfdb3f543d6734fbcc4b2b0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:def69773c7874ac31f34686dbd0842f332f00056ce99606ca31febf112ae8f83 +size 43032 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/71f58913e01272d6e8c4c9bcc8d5afc0_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/71f58913e01272d6e8c4c9bcc8d5afc0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ca0b8a7daedb4b35e71f069bbf3ae54b10c57ca8 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/71f58913e01272d6e8c4c9bcc8d5afc0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:81389a4708c088150cc395e16fd110a10e479648e9ec459061bdcff2d4002601 +size 55374 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/725624f6559db546f718a77abd0608cd_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/725624f6559db546f718a77abd0608cd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d7815e35bb0c987e238eabc540a306b441eb3590 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/725624f6559db546f718a77abd0608cd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ec6422e9b9801feabee813079e738588268592027762bf8fe4a2ff3116a58c8 +size 2954 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/746e4f6f1069e45b056e56f2178c6ef2_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/746e4f6f1069e45b056e56f2178c6ef2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..33ef93bf9da860c97c28624b7aeaf6b6cc8c8c4c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/746e4f6f1069e45b056e56f2178c6ef2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b7f1a073a1ca933e56bbea5d841b695b3332ed5c53b4ff6ad71b11b52473053a +size 25889 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/7b5cf586beef7e75525810d1929fcf9b_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/7b5cf586beef7e75525810d1929fcf9b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f72eeb418e0986bb1a0150150dd43bb6d739359c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/7b5cf586beef7e75525810d1929fcf9b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8b8b7fa7cdbf516b1a6d85b2927205dd5bc1f10eb91f5f8266a7a8d335ef25fe +size 35953 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/7ed34bd72a1469d768ed6ccb28249b5d_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/7ed34bd72a1469d768ed6ccb28249b5d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b8d0b70fefe228438c99fe3678f17b7f7128df00 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/7ed34bd72a1469d768ed6ccb28249b5d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f3a49160521f7882bf529acc47f53329e2fd25e7246d9d1671c4fb75a255ec6a +size 38979 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/8115ced389b6a8c0418275401653b176_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/8115ced389b6a8c0418275401653b176_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e3eadb2b170e05fde368d1707f905426be8d713e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/8115ced389b6a8c0418275401653b176_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9c25898fde040e26780d82ec5646ea108529b0584772ba18696007750658e8a5 +size 51290 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/8df8301d88ae3746ee7c9d8fc48df1cd_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/8df8301d88ae3746ee7c9d8fc48df1cd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9bf4294765e65a4f6aeee1532086e211bfe710d5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/8df8301d88ae3746ee7c9d8fc48df1cd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e3adb1ba3d1cd57e3143ed309e4546218197017b4cdf7b0472c8af4a8cee51c +size 158845 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/920674382dd86f548a644c9a5f35a6a9_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/920674382dd86f548a644c9a5f35a6a9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9b077263571878bfda733734e62cb456179ca19a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/920674382dd86f548a644c9a5f35a6a9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2ec9c0d27d8b7b299d4bdc58cd27a72e54cbddffd1eb9150abebd2bc55a785a4 +size 73632 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/92998b1ce11cc3176ade42df63ecdcde_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/92998b1ce11cc3176ade42df63ecdcde_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..66709e12b72e6d57a5d5f97c53630f1203e5261f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/92998b1ce11cc3176ade42df63ecdcde_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6860e5bdc6bf70ca22b366a1711ad820e132323bfda0d0e5550ea8b9f1b9d96b +size 117029 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/9786c0dac9f8ebe0d164c9cca3901408_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/9786c0dac9f8ebe0d164c9cca3901408_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d80c087fd8f79c09ad6dbee432e0ecd3f59622f7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/9786c0dac9f8ebe0d164c9cca3901408_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:00dc6381ce05ddc0b43a36d7b3218f919528c9e6f808c03dbd2c2954401fd3bd +size 4064 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/99712893dc09ed4c8e384f854d7d86a7_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/99712893dc09ed4c8e384f854d7d86a7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2395bacf78acd75bcf55c42b04e21ba1a2321e49 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/99712893dc09ed4c8e384f854d7d86a7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7ac2b9e1227298df4ee67a87841952e7145f2eab1882c17871deb6b34b591db2 +size 37313 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/9f1ec8232712fd5ba7a9c3bb7bf02b05_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/9f1ec8232712fd5ba7a9c3bb7bf02b05_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fbea9ed55bd65c10b98c49d196a375f5db8c6ad6 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/9f1ec8232712fd5ba7a9c3bb7bf02b05_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cc65cdba76956c00aac9657b2e50e5a9abb2aa46714eac8725e24140484701a3 +size 69262 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/a74539572e5d089b7db6aa6d8bda124c_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/a74539572e5d089b7db6aa6d8bda124c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..533ddd1552010ac3d4f1af7f44a83bfded80c13d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/a74539572e5d089b7db6aa6d8bda124c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d19a45169b316c37251d7ba938f674504919889df736a181c78a0cd3cd3862c5 +size 51335 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/a86530966260e7a888d5b4a0e9f85a58_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/a86530966260e7a888d5b4a0e9f85a58_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f53742548d1641cf176774e55ae871b9f42d1954 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/a86530966260e7a888d5b4a0e9f85a58_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c3a68a9494560e8bff97aba4b49e220ce5ca4935efa5f558a1aac3d0cfd81489 +size 47319 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/aa6cae25ba7badb8b6ee9d464a1f1478_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/aa6cae25ba7badb8b6ee9d464a1f1478_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..13f5d8b19ce6314d0cda691fbac5af7e0a47458e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/aa6cae25ba7badb8b6ee9d464a1f1478_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ded4739a827d4626da910cdb5146d34febaa647e134350ff08b4254696dee8bf +size 77125 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/ac4817255adf7ecc9dc974f5ac506e76_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/ac4817255adf7ecc9dc974f5ac506e76_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2b452f2145265e99cd15b82ae4f38ddcddf0babd --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/ac4817255adf7ecc9dc974f5ac506e76_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1c46ab192495f14144e94be0300448eb6b903a288ef4e5a6f4f4e8e775af3960 +size 3070 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/aca3071c37b85b6ad6ee8ceec9363c6f_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/aca3071c37b85b6ad6ee8ceec9363c6f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c722288f29675bf984fb481fe9264a7b98df7e95 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/aca3071c37b85b6ad6ee8ceec9363c6f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cb9abd99f2b287a6d824925c8098998080c217160580c31a6b7b357552453084 +size 36874 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/b095e9af5e890100bcb209c62748dee4_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/b095e9af5e890100bcb209c62748dee4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d26f46e0dc289aa91fa00a1da1b5a68894791c8e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/b095e9af5e890100bcb209c62748dee4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:241cdf3e923b38f2568eafeac624defe83a17ee420ccd7a34743b6a88ee9cbab +size 128083 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/b87403b8c7182ada6d6b9c8ae467ff0a_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/b87403b8c7182ada6d6b9c8ae467ff0a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a3cf43c29ad55716c030ed22e58eb1687f07e3a9 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/b87403b8c7182ada6d6b9c8ae467ff0a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:200da85284faf9bd317045f4726cb4e283cb4c92b299a2688956cf050f53638b +size 73994 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/bde09174f9ec7bf546d992a507721272_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/bde09174f9ec7bf546d992a507721272_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..10855535e0defc4f12d74842c3f8e67bc84c465d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/bde09174f9ec7bf546d992a507721272_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e0a8b49ae09e3e81574cb2ad54211eb668d10cc0e6f49cd5abb3ae643932cb9c +size 58317 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/cac2388d8ab649cec9ffe10c6b295303_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/cac2388d8ab649cec9ffe10c6b295303_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9164c36fa308c68fd0713a14e7ac9fcc9a648b9c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/cac2388d8ab649cec9ffe10c6b295303_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:758eea49fa5311ceebfc5b448a4a2f4575735551bd9f61ba486dce0663bf097f +size 32595 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/cd738102c02acc351e4e33ce4de5131c_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/cd738102c02acc351e4e33ce4de5131c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1048cea148aae05926fc46b49b83dd0afcf8ffa1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/cd738102c02acc351e4e33ce4de5131c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8100469951b40950a839361087dc2cc8ad8c2dc9b08dba0ac139dd187d7b4ca0 +size 2959 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/d302a24196034b009fe3b3e15c72650f_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/d302a24196034b009fe3b3e15c72650f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9891292eb43db15a6b2d09971d6af3c231af948b --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/d302a24196034b009fe3b3e15c72650f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b53dcf92d338913b4ba6f8b4386de6ca311e48b639921214a4b7145ba8c7b75c +size 43842 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/d9d43f33b3d1ba3130af40af697bc766_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/d9d43f33b3d1ba3130af40af697bc766_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6169d8ee87ec6dc79527a1d0a3a75fa055fe2030 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/d9d43f33b3d1ba3130af40af697bc766_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1fdb8e1d12d34fbffdadc9bb3a0860605b92f235432a1574baabe1f44193f4b1 +size 75338 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/de553409fa4d0389bc673ca131864da8_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/de553409fa4d0389bc673ca131864da8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..86e7b0c5ed60a337bac2fdad7a602a40835556e7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/de553409fa4d0389bc673ca131864da8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f384b10235eba855d208cab0f856bed18dbba5966f76ac07f69afa9f12907ab3 +size 45745 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/df13dcad8b8ab6a9e28e485c8fdee29b_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/df13dcad8b8ab6a9e28e485c8fdee29b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..96b34ec0fb5496436689b4f60fa5609739638476 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/df13dcad8b8ab6a9e28e485c8fdee29b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b04908b18720e1c836d160442f707d11878d8d40f19a95e5a8521ba4430fa3d +size 44263 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/e37b91735716838dae0b677f2b36084d_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/e37b91735716838dae0b677f2b36084d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ba8ffa35662d5c5707493d023decc08bce762d2c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/e37b91735716838dae0b677f2b36084d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e893b300f3f208ae8693579d1d42d8d6c7563b0c7efbc4f00af89bfd3349ab1 +size 3071 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/e891944b37f286de820c361071556461_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/e891944b37f286de820c361071556461_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..028e68fbaf158b3e9ba2492c35d66dc0e6afd689 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/e891944b37f286de820c361071556461_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b686fbfcd512bbe0ea088e8398032e443074f97fe68e3a81ae65883dd1c9a12 +size 91932 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/ebebbec8741470c66cafe9a52547e899_img.jpg b/marked/WG6/O-RAN.WG6.CADS-v08.01/ebebbec8741470c66cafe9a52547e899_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8eb882328b1e0368185c4565ebbed9e43048e1b6 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/ebebbec8741470c66cafe9a52547e899_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:92d2dac353f1bbd1b5d476a54a8a800e5e4e210ceb30a267241f1a4145ebb347 +size 46174 diff --git a/marked/WG6/O-RAN.WG6.CADS-v08.01/raw.md b/marked/WG6/O-RAN.WG6.CADS-v08.01/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..f6f2e2d7f86e235ab3093ae3571dce92e06ba7f6 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CADS-v08.01/raw.md @@ -0,0 +1,2040 @@ + + +# **O-RAN Working Group 6 Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN** --- + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +2 + +# Table of Contents + +| | | | +|----|-----------------------------------------------------------------------------------------------------|----| +| 4 | Table of Contents ..... | 2 | +| 5 | Table of Figures..... | 3 | +| 6 | Table of Tables ..... | 4 | +| 7 | 1 Scope..... | 5 | +| 8 | 1.1 Context; Relationship to Other O-RAN Work..... | 5 | +| 9 | 1.2 Objectives ..... | 5 | +| 10 | 2 References ..... | 7 | +| 11 | 3 Definitions and Abbreviations ..... | 8 | +| 12 | 3.1 Definitions ..... | 8 | +| 13 | 3.2 Abbreviations..... | 10 | +| 14 | 4 Overall Architecture..... | 12 | +| 15 | 4.1 O-RAN Functions Definitions ..... | 12 | +| 16 | 4.2 Degree of Openness ..... | 13 | +| 17 | 4.3 Decoupling of Hardware and Software..... | 13 | +| 18 | 4.3.1 The O-Cloud..... | 14 | +| 19 | 4.3.2 Key O-Cloud Concepts ..... | 15 | +| 20 | 4.3.3 O-Cloud Platform Management Functionalities..... | 20 | +| 21 | 4.4 O-Cloud Multi-Site Networking..... | 20 | +| 22 | 4.4.1 O-Cloud and Transport Network Shared Connectivity Information ..... | 21 | +| 23 | 5 Deployment Scenarios: Common Considerations..... | 21 | +| 24 | 5.1 Mapping Logical Functionality to Physical Implementations ..... | 22 | +| 25 | 5.1.1 Technical Constraints that Affect Hardware Implementations..... | 22 | +| 26 | 5.1.2 Service Requirements that Affect Implementation Design ..... | 22 | +| 27 | 5.1.3 Rationalization of Centralizing O-DU Functionality ..... | 23 | +| 28 | 5.2 Performance Aspects ..... | 25 | +| 29 | 5.2.1 User Plane Delay ..... | 25 | +| 30 | 5.3 Hardware Acceleration and Acceleration Abstraction Layer (AAL)..... | 28 | +| 31 | 5.3.1 Accelerator Deployment Model..... | 29 | +| 32 | 5.3.2 Acceleration Abstraction Layer (AAL) Interface..... | 29 | +| 33 | 5.3.3 Accelerator Management and Orchestration Considerations ..... | 30 | +| 34 | 5.4 Cloud Considerations..... | 30 | +| 35 | 5.4.1 Networking requirements..... | 30 | +| 36 | 5.4.1.1 Support for Multiple Networking Interfaces..... | 30 | +| 37 | 5.4.1.2 Support for High Performance N-S Data Plane ..... | 30 | +| 38 | 5.4.1.3 Support for High-Performance E-W Data Plane..... | 31 | +| 39 | 5.4.1.4 Support for Service Function Chaining ..... | 32 | +| 40 | 5.4.1.5 Support for VLAN based networking..... | 32 | +| 41 | 5.4.1.6 Support for O-Cloud Gateways to connect O-Cloud Sites with external Transport Networks..... | 32 | +| 42 | 5.4.2 Assignment of Acceleration Resources..... | 33 | +| 43 | 5.4.3 Real-time / General Performance Feature Requirements ..... | 33 | +| 44 | 5.4.3.1 Host Linux OS ..... | 33 | +| 45 | 5.4.3.1.1 Support for Pre-emptive Scheduling ..... | 33 | +| 46 | 5.4.3.2 Support for Node Feature Discovery ..... | 33 | +| 47 | 5.4.3.3 Support for CPU Affinity and Isolation..... | 33 | +| 48 | 5.4.3.4 Support for Dynamic HugePages Allocation..... | 34 | +| 49 | 5.4.3.5 Support for Topology Manager ..... | 34 | +| 50 | 5.4.3.6 Support for Scale In/Out..... | 34 | +| 51 | 5.4.3.7 Support for Device Plugin ..... | 35 | +| 52 | 5.4.3.8 Support for Direct IRQ Assignment ..... | 35 | +| 53 | 5.4.3.9 Support for No Over Commit CPU ..... | 35 | +| 54 | 5.4.3.10 Support for Specifying CPU Model..... | 35 | +| 55 | 5.4.4 Storage Requirements ..... | 36 | + +2 + +| | | | | +|----|-------------|-------------------------------------------------------------------------------------------|----| +| 56 | 5.4.5 | Notification Subscription Framework ..... | 36 | +| 57 | 5.4.5.1 | O-Cloud Notification Subscription Requirements ..... | 36 | +| 58 | 5.5 | Sync Architecture ..... | 37 | +| 59 | 5.5.1 | Cloud Platform Time Synchronization Architecture ..... | 37 | +| 60 | 5.5.1.1 | Edge Cloud Site Level – LLS-C3 Synchronization Topology ..... | 38 | +| 61 | 5.5.1.1.1 | LLS-C3 Synchronization Topology Edge Site Time Synchronization Architecture ..... | 38 | +| 62 | 5.5.1.1.2 | LLS-C3 Synchronization Topology Edge Site Requirements ..... | 39 | +| 63 | 5.5.1.1.2.1 | Software ..... | 39 | +| 64 | 5.5.1.1.2.2 | Hardware ..... | 39 | +| 65 | 5.5.1.2 | Edge Cloud Site Level – LLS-C1 Synchronization Topology ..... | 39 | +| 66 | 5.5.1.2.1 | LLS-C1 Synchronization Topology Edge Site Time Synchronization Architecture ..... | 39 | +| 67 | 5.5.1.2.2 | LLS-C1 Synchronization Topology Edge Site Requirements ..... | 41 | +| 68 | 5.5.1.2.2.1 | Software ..... | 41 | +| 69 | 5.5.1.2.2.2 | Hardware ..... | 41 | +| 70 | 5.5.2 | Loss of Synchronization Notification ..... | 41 | +| 71 | 5.6 | Operations and Maintenance Considerations ..... | 42 | +| 72 | 5.7 | Transport Network Architecture ..... | 43 | +| 73 | 5.7.1 | Fronthaul Gateways/Fronthaul Multiplexers ..... | 43 | +| 74 | 5.8 | Overview of Deployment Scenarios ..... | 44 | +| 75 | 6 | Deployment Scenarios and Implementation Considerations ..... | 45 | +| 76 | 6.1 | Scenario A ..... | 45 | +| 77 | 6.1.1 | Key Use Cases and Drivers ..... | 46 | +| 78 | 6.2 | Scenario B ..... | 46 | +| 79 | 6.2.1 | Key Use Cases and Drivers ..... | 47 | +| 80 | 6.3 | Scenario C ..... | 47 | +| 81 | 6.3.1 | Key Use Cases and Drivers ..... | 48 | +| 82 | 6.3.2 | Scenario C.1, and Use Case and Drivers ..... | 48 | +| 83 | 6.3.3 | Scenario C.2, and Use Case and Drivers ..... | 49 | +| 84 | 6.4 | Scenario D ..... | 51 | +| 85 | 6.5 | Scenario E ..... | 51 | +| 86 | 6.5.1 | Key Use Cases and Drivers ..... | 52 | +| 87 | 6.5.2 | Scenario E.1 vO-DU with O-RU ..... | 52 | +| 88 | 6.6 | Scenario F ..... | 52 | +| 89 | 6.6.1 | Key Use Cases and Drivers ..... | 53 | +| 90 | 6.7 | Scenarios of Initial Interest ..... | 53 | +| 91 | 7 | Appendix A (informative): Extensions to Current Deployment Scenarios to Include NSA ..... | 53 | +| 92 | 7.1 | Scenario A ..... | 54 | +| 93 | 7.2 | Scenario B ..... | 54 | +| 94 | 7.3 | Scenario C ..... | 54 | +| 95 | 7.4 | Scenario C.2 ..... | 54 | +| 96 | 7.5 | Scenario D ..... | 55 | +| 97 | | Annex (Informative): Change History ..... | 55 | +| 98 | | | | + +###### 99 Table of Figures + +| | | | +|-----|----------------------------------------------------------------------------------------------------------------------|----| +| 100 | Figure 1: Relationship of this Document to Scenario Documents and O-RAN Management Documents ..... | 5 | +| 101 | Figure 2: Major Components Related to the Orchestration and Cloudification Effort ..... | 6 | +| 102 | Figure 3: Example of Tiered Clouds/mapped to O-Clouds and Sites ..... | 7 | +| 103 | Figure 4: High Level Architecture of O-RAN ..... | 12 | +| 104 | Figure 5: Logical Architecture of O-RAN ..... | 13 | +| 105 | Figure 6: Decoupling, and Illustration of the O-Cloud Concept ..... | 14 | +| 106 | Figure 7: Relationship between RAN Functions and Demands on Cloud Infrastructure and Hardware ..... | 15 | +| 107 | Figure 8: Key Components Involved in/with an O-Cloud ..... | 16 | +| 108 | Figure 9: Example of O-Cloud Resources mapped to O-Cloud Nodes and O-Cloud Networks in an O-Cloud Node Cluster ..... | 18 | +| 109 | | | +| 110 | Figure 10: Edge O-Cloud Site deployment example with an O-Cloud Site Network Fabric (Hub) ..... | 19 | +| 111 | Figure 11: Edge O-Cloud Site deployment example without an O-Cloud Site Network Fabric (Single servers) ..... | 19 | + +| | | | +|-----|--------------------------------------------------------------------------------------------------------------|----| +| 112 | Figure 12: Simple Centralization of O-DU Resources ..... | 23 | +| 113 | Figure 13: Pooling of Centralized O-DU Resources..... | 24 | +| 114 | Figure 14: Comparison of Merit of Centralization Options vs. Number of Cell Sites in a Pool..... | 24 | +| 115 | Figure 15: Major User Plane Latency Components, by 5G Service Slice and Function Placement ..... | 26 | +| 116 | Figure 16: Hardware Abstraction Considerations..... | 29 | +| 117 | Figure 17: Accelerator APIs/Libraries in Container and Virtual Machine Implementations..... | 29 | +| 118 | Figure 18: Illustration of the Network Interfaces Attached to a Pod, as Provisioned by Multus CNI ..... | 30 | +| 119 | Figure 19: Illustration of the Userspace CNI Plugin..... | 31 | +| 120 | Figure 20: Example Illustration of Two NUMA Regions ..... | 34 | +| 121 | Figure 21: O-Cloud Notification Framework Architecture ..... | 37 | +| 122 | Figure 22: Edge Cloud Site Time Sync Architecture for LLS-C3 ..... | 38 | +| 123 | Figure 23: Hyperconverged Edge Cloud Time Sync Architecture for LLS-C3..... | 39 | +| 124 | Figure 24: Edge Cloud Site Time Sync Architecture for LLS-C1 ..... | 40 | +| 125 | Figure 25: Hyperconverged Edge Cloud Time Sync Architecture for LLS-C1..... | 41 | +| 126 | Figure 26: vO-DU Subscribes to PTP Notification ..... | 42 | +| 127 | Figure 27: High-Level Comparison of Scenarios ..... | 44 | +| 128 | Figure 28: Scenario A..... | 45 | +| 129 | Figure 29: Scenario B – NR Stand-alone..... | 46 | +| 130 | Figure 30: Scenario B – MR-DC (inter-RAT NR and E-UTRA) regardless of the Core Network type (either EPC or | | +| 131 | 5GC) ..... | 46 | +| 132 | Figure 31: Scenario C ..... | 48 | +| 133 | Figure 32: Treatment of Network Slices: MEC for URLLC at Edge Cloud, Centralized Control, Single vO-DU ..... | 49 | +| 134 | Figure 33: Scenario C.1 ..... | 49 | +| 135 | Figure 34: Treatment of Network Slice: MEC for URLLC at Edge Cloud, Separate vO-DUs ..... | 50 | +| 136 | Figure 35: Single O-RU Being Shared by More than One Operator ..... | 50 | +| 137 | Figure 36: Scenario C.2 ..... | 51 | +| 138 | Figure 37: Scenario D ..... | 51 | +| 139 | Figure 38: Scenario E ..... | 52 | +| 140 | Figure 39: Scenario E.1 ..... | 52 | +| 141 | Figure 40: Scenario F..... | 53 | +| 142 | Figure 41: Scenario A, Including NSA..... | 54 | +| 143 | Figure 42: Scenario C, Including NSA ..... | 54 | +| 144 | Figure 43: Scenario C.2, Including NSA ..... | 55 | +| 145 | Figure 44: Scenario D, Including NSA..... | 55 | + +# Table of Tables + +| | | | +|-----|----------------------------------------------------------------------|----| +| 147 | Table 1: Service Delay Constraints and Major Delay Contributors..... | 26 | +| 148 | Table 2: Cardinality and Delay Performance for Scenario B..... | 47 | +| 149 | Table 3: Cardinality and Delay Performance for Scenario C..... | 48 | +| 150 | Table 4: Cardinality and Delay Performance for Scenario C.1..... | 49 | + +151 + +152 + +# 1 Scope + +This Technical Report has been produced by the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should O-RAN modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Version x.y.z + +where: + +x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). + +y the second digit is incremented when editorial only changes have been incorporated in the document. + +z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +## 1.1 Context; Relationship to Other O-RAN Work + +This document introduces and examines different scenarios and use cases for O-RAN deployments of Network Functionality into Cloud Platforms, O-RAN Cloudified NFs and O-RAN Physical NFs. Deployment scenarios are associated with meeting customer and service requirements, while considering technological constraints and the need to create cost-effective solutions. It will also reference management considerations covered in more depth elsewhere. + +The following O-RAN documents will be referenced (see Section 5.6): + +- OAM architecture specification [8] +- OAM interface specification (O1) [9] +- O-RAN Architecture Description [10] + +The details of implementing each identified scenario will be covered in separate Scenario documents, shown in green in Figure 1. + +![Figure 1: Relationship of this Document to Scenario Documents and O-RAN Management Documents. The diagram shows a central blue box labeled 'Cloud Architecture and Deployment Scenarios'. To its left, under 'Management documents', are two purple boxes: 'OAM Architecture' and 'OAM Interface Specification'. To its right, under 'Architecture documents', is a purple box labeled 'O-RAN Architecture Description'. Yellow double-headed arrows connect the central box to each of these three boxes. Below the central box, three green boxes labeled 'Scenario Reference Design' are connected by lines, with an ellipsis between the second and third boxes.](7ed34bd72a1469d768ed6ccb28249b5d_img.jpg) + +``` + +graph TD + subgraph Management_documents [Management documents] + OAM_Architecture[OAM Architecture] + OAM_Interface[OAM Interface Specification] + end + subgraph Architecture_documents [Architecture documents] + O_RAN_Architecture[O-RAN Architecture Description] + end + subgraph Scenario_Designs [Scenario Reference Design] + S1[Scenario Reference Design] + S2[Scenario Reference Design] + S3[Scenario Reference Design] + S2 --- Dots[...] + end + Cloud[Cloud Architecture and Deployment Scenarios] + Cloud <--> OAM_Architecture + Cloud <--> OAM_Interface + Cloud <--> O_RAN_Architecture + Cloud --- S1 + Cloud --- S2 + Cloud --- S3 + +``` + +Figure 1: Relationship of this Document to Scenario Documents and O-RAN Management Documents. The diagram shows a central blue box labeled 'Cloud Architecture and Deployment Scenarios'. To its left, under 'Management documents', are two purple boxes: 'OAM Architecture' and 'OAM Interface Specification'. To its right, under 'Architecture documents', is a purple box labeled 'O-RAN Architecture Description'. Yellow double-headed arrows connect the central box to each of these three boxes. Below the central box, three green boxes labeled 'Scenario Reference Design' are connected by lines, with an ellipsis between the second and third boxes. + +**Figure 1: Relationship of this Document to Scenario Documents and O-RAN Management Documents** + +This document also draws on some other work from other O-RAN working groups, as well as sources from other industry bodies. + +## 1.2 Objectives + +The O-RAN Alliance seeks to improve RAN flexibility and deployment velocity, while at the same time reducing the capital and operating costs through the adoption of cloud architectures. The structure of the Orchestration and Cloudification work is shown graphically below. This document focuses on the Cloudification deployment aspects as indicated. + +Editor's note: O-RU cloudification and O-RU AAL are future study items. + +![Figure 2: Major Components Related to the Orchestration and Cloudification Effort. The diagram illustrates the transition from a traditional Blackbox BBU (S/W and H/W) to a cloudified architecture. The cloudified architecture is divided into two main sections: Orchestration and Cloudification. The Orchestration section includes a Flexible Orch. block (Inventory, Discovery, Registration, Policy, Metrics) and Common LCM mechanisms across VNF & PNFs. The Cloudification section includes O-CU, O-DU, and O-RU modules, each with an AAL (Application and Adaptation Layer). These modules are supported by a Cloud stack (Containers/VMs, OS, Cloud Mgmt.) and a multitude of silicon accelerators (x86, FPGA, GPU, ASIC). The architecture also supports various deployment models: Centralized CU/DU (C-RAN), CU/DU split, and Distributed CU/DU (D-RAN).](aa6cae25ba7badb8b6ee9d464a1f1478_img.jpg) + +Figure 2: Major Components Related to the Orchestration and Cloudification Effort. The diagram illustrates the transition from a traditional Blackbox BBU (S/W and H/W) to a cloudified architecture. The cloudified architecture is divided into two main sections: Orchestration and Cloudification. The Orchestration section includes a Flexible Orch. block (Inventory, Discovery, Registration, Policy, Metrics) and Common LCM mechanisms across VNF & PNFs. The Cloudification section includes O-CU, O-DU, and O-RU modules, each with an AAL (Application and Adaptation Layer). These modules are supported by a Cloud stack (Containers/VMs, OS, Cloud Mgmt.) and a multitude of silicon accelerators (x86, FPGA, GPU, ASIC). The architecture also supports various deployment models: Centralized CU/DU (C-RAN), CU/DU split, and Distributed CU/DU (D-RAN). + +**Figure 2: Major Components Related to the Orchestration and Cloudification Effort** + +A key principle is the decoupling of RAN hardware and software for all components including near-RT RIC, O-CU (O-CU-CP and O-CU-UP), O-DU, and O-RU, and the deployment of software components on commodity server architectures supplemented with programmable accelerators where necessary. + +Key characteristics of cloud architectures which we will reference in this document are: + +- Decoupling of hardware from software. This aims to improve flexibility and choice for operators by decoupling selection and deployment of hardware infrastructure from software selection, +- Standardization of hardware specifications across software implementations, to simplify physical deployment and maintenance. This aims to promote the availability of a multitude of *software* implementation choices for a given hardware configuration. +- Sharing of hardware. This aims to promote the availability of a multitude of *hardware* implementation choices for a given software implementation. +- Flexible instantiation and lifecycle management through orchestration automation. This aims to reduce deployment and ongoing maintenance costs by promoting simplification and automation throughout the hardware and software lifecycle through common chassis specifications and standardized orchestration interfaces. + +This document will define various deployment scenarios that can be supported by the O-RAN specifications and are of either current or relatively near-term interest. Each scenario is identified by a specific grouping of functionality (Tiered Clouds) at different key locations (Cell Site, Edge Cloud, Regional Cloud and Central Cloud, which will be defined shortly), and an identification of whether functionality at a given location is provided by an O-RAN Physical NF based solution where software and hardware are tightly integrated and sharing a single identity, or by an O-RAN cloud infrastructure architecture (O-Cloud) that meets the above requirements. + +The scope of this work clearly includes supporting all 5G technologies, i.e. E-UTRA and NR with both EPC-based Non-Standalone (NSA) and 5GC architectures. This implies that cloud/orchestration aspects of NSA (E-UTRA) are also supported. However, this version primarily addresses 5G SA deployments. + +This technical report examines the constraints that drive a specific solution, and discuss the hierarchical properties of each solution, including a rough scale of the size of each Tiered Cloud and a sense of the number of sub clouds expected to be served by a higher tiered cloud. Figure 3 shows as example of how multiple Cell Sites feed into a smaller number of Edge Clouds, and how in turn multiple Edge Clouds feed into a Regional Cloud that can feed into a Central Cloud. For a given scenario, the Logical Functions are distributed in a certain way among each type of Tiered Cloud, and the “cardinality” of the different functions will be discussed. + +The present document describes that the Cloud Infrastructure is deployed as managed O-Cloud(s). Tiered Cloud is a conceptual construct of grouped functions in an O-RAN. Their physical manifestation is realized in O-Clouds on Cloud Sites. Cell Sites connect into the Cloud Site O-Cloud Resources through the Fronthaul network. Cloud Sites and Cell Sites could be collocated at the same site location or separately on their own individual site locations. The document also + + + +- [1] 3GPP TS 38.470, *NG-RAN; F1 general aspects and principles*. +- [2] 3GPP TR 21.905, *Vocabulary for 3GPP Specifications*. +- [3] eCPRI Interface Specification V1.2, *Common Public Radio Interface: eCPRI Interface Specification*. +- [4] eCPRI Transport Network V1.2, Requirements Specification, *Common Public Radio Interface: Requirements for the eCPRI Transport Network*. +- [5] IEEE Std 802.1CM-2018, *Time-Sensitive Networking for Fronthaul*. +- [6] ITU-T Technical Report, *GSTR-TN5G - Transport network support of IMT-2020/5G*. +- [7] O-RAN WG4, *Control, User and Synchronization Plane Specification*, Technical Specification. See <https://www.o-ran.org/specifications>. +- [8] O-RAN WG1, *Operations and Maintenance Architecture*, Technical Specification. See <https://www.o-ran.org/specifications>. +- [9] O-RAN WG1, *Operations and Maintenance Interface Specification*, Technical Specification. See <https://www.o-ran.org/specifications>. +- [10] O-RAN WG1, *O-RAN Architecture Description*, Technical Specification. See <https://www.o-ran.org/specifications>. +- [11] 3GPP TS 28.622, *Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS)*. +- [12] O-RAN WG6, *Cloud Platform Reference Design for Deployment Scenario B*, Technical Specification. See <https://www.o-ran.org/specifications>. +- [13] O-RAN WG7 OMAC HAR 0-v01.00 O-RAN White Box Hardware Working Group Outdoor Macrocell Hardware Architecture and Requirements (FR1) Specification. +- [14] O-RAN WG1, Use Cases Detailed Specifications – v05.00, Technical Specification. See <https://www.o-ran.org/specifications>. +- [15] O-RAN.WG7.DSC.0-v04.00 O-RAN White Box Hardware Working Group Deployment Scenarios and Base Station Classes. + +# 3 Definitions and Abbreviations + +## 3.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [2] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [2]. + +| | | +|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Cell Site | This refers to the location of Radio Units (RUs); e.g., placed on same structure as the Radio Unit or at the base. The Cell Site in general will support multiple sectors and hence multiple O-RUs. | +| Cloud Infrastructure (CInf) | This refers to a set of computation, storage and networking equipment with related software that offers physical and/or virtual cloud resources and services into the O-Cloud as an under-cloud from the Cloud Infrastructure provider organization that could be operator internal or external. The Cloud Infrastructure resources are not addressed by the present document and not specified as part of O2ims and O2dms. | +| CInf Management | This is a vendor or operator software operated by the Cloud Infrastructure provider organization. It handles discovery, health and maintenance of the Cloud Infrastructure included equipment and its offered physical and logical services that can be distributed over multiple Cloud Sites. The Cloud Infrastructure Management are not addressed by the present document and not specified as part of O2ims and O2dms. | + +| | | | +|-----|-------------------------------|----------------------------------------------------------------------------------------------------------| +| 301 | Central Cloud | This is the highest location tier, that supports virtualized RAN and other functions, and | +| 302 | | provides the centralization of functionality that has the least strict network latency | +| 303 | | requirements. | +| 304 | Cloud Site | This refers to a physical place that has Cloud Infrastructure resources that can be used for O- | +| 305 | | Clouds and potentially other non-O-Cloud resources. | +| 306 | CIDR | Classless Inter-Domain Routing (also known as Subnet Mask) | +| 307 | Edge Cloud | This is a location that supports virtualized RAN functions for multiple Cell Sites and provides | +| 308 | | centralization of functions for those sites and associated economies of scale. An Edge Cloud | +| 309 | | might serve a large physical area or a relatively small one close to its cell sites, depending on | +| 310 | | the Operator's use case. However, the sites served by the Edge Cloud must be near enough to | +| 311 | | the O-RUs to meet the network latency requirements of the O-DU functions. | +| 312 | F1 Interface | The open interface between O-CU and O-DU in this document is the same as that defined by | +| 313 | | the CU and DU split in 3GPP TS 38.473. It consists of an F1-u part and an F1-c part. | +| 314 | Managed Element | [11]Refer to the 3GPP TS 28.622 [11] . | +| 315 | Managed Function | Refer to the 3GPP TS 28.622 [11] | +| 316 | Network Function | The O-RAN Network Functions (O-RAN NFs) are defined in the O-RAN Architecture | +| 317 | | Description [10]. | +| 318 | Regional Cloud | This is a location that supports virtualized RAN functions for many Cell Sites in multiple Edge | +| 319 | | Clouds and provides high centralization of functionality. The sites served by the Regional | +| 320 | | Cloud must be near enough to the O-DUs to meet the network latency requirements of the O- | +| 321 | | CU and near-RT RIC. | +| 322 | O-Cloud | This refers to a collection of O-Cloud Resource Pools at one or more location and the software | +| 323 | | to manage Nodes and Deployments hosted on them. An O-Cloud will include functionality to | +| 324 | | support both Deployment-plane and Management services. The O-Cloud provides a single | +| 325 | | logical reference point for all O-Cloud Resource Pools within the O-Cloud boundary. | +| 326 | O-Cloud Capability | One or more features provided by the O-Cloud Platform and exposed to consumers for | +| 327 | | performing certain tasks. | +| 328 | NOTE 1: Consumers | include software deployments, such as NF Deployments, and management services (e.g. NFO | +| 329 | | and FOCOM) interacting with the O-Cloud. | +| 330 | NOTE 2: An O-Cloud Capability | can be associated with certain capacity. | +| 331 | EXAMPLE: | Examples of O-Cloud Capabilities are computing processing, acceleration, storage, etc. | +| 332 | O-RAN Physical NF | A RAN NF software deployed on tightly integrated hardware sharing a single Managed | +| 333 | | Element identity. | +| 334 | Cloudified NF | A RAN Network Function software that is deployed in the O-Cloud via one or more NF | +| 335 | | Deployments. | +| 336 | NF Deployment | A software deployment on O-Cloud resources that realizes, all or part of, a Cloudified NF. | +| 337 | PE | Provider Edge | +| 338 | Tiered Cloud | The definition of Tiered Clouds is a grouping of O-RAN related functionality called Cell Site, | +| 339 | | Edge Cloud, Regional Cloud and Central Cloud where each tier has increasing latency and | +| 340 | | increasing maximum area covered per tier. | +| 341 | NOTE: The Tiered Cloud | and its different locations are conceptual and intended to enable discussions around | +| 342 | | functional placement and its requirements in O-RAN. It is not an exact definition, and it doesn't have a | +| 343 | | direct mapping to the realization of the functionality. | +| 344 | | | + +## 3.2 Abbreviations + +For the purposes of this document, the abbreviations given in 3GPP TR 21.905 [2] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [2]. + +| | | +|--------|-----------------------------------------------------| +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth-Generation Mobile Communications | +| AAL | Acceleration Abstraction Layer | +| API | Application Programming Interface | +| ASIC | Application-Specific Integrated Circuit | +| BBU | BaseBand Unit | +| BS | Base Station | +| CI | Cloud Infrastructure | +| CoMP | Co-Ordinated Multi-Point transmission/reception | +| CNF | Cloud-Native Network Function | +| CNI | Container Networking Interface | +| CPU | Central Processing Unit | +| CR | Cell Radius | +| CU | Centralized Unit as defined by 3GPP | +| DFT | Discrete Fourier Transform | +| DL | Downlink | +| DPDK | Data Plan Development Kit | +| DMS | Deployment Management Services | +| DU | Distributed Unit as defined by 3GPP | +| eMBB | enhanced Mobile BroadBand | +| EPC | Evolved Packet Core | +| E-UTRA | Evolved UMTS Terrestrial Radio Access | +| FCAPS | Fault Configuration Accounting Performance Security | +| FEC | Forward Error Correction | +| FFT | Fast Fourier Transform | +| FH | Fronthaul | +| FHGW | Fronthaul Gateway | +| FHM | Fronthaul Multiplexer | +| FPGA | Field Programmable Gate Array | +| GNSS | Global Navigation Satellite System | +| GPP | General Purpose Processor | +| GPS | Global Positioning System | +| GPU | Graphics Processing Unit | +| HARQ | Hybrid Automatic Repeat ReQuest | +| HW | Hardware | +| IEEE | Institute of Electrical and Electronics Engineers | +| IM | Information Modelling, or Information Model | +| IMS | Infrastructure Management Services | +| IRQ | Interrupt ReQuest | +| ISA | Instruction Set Architecture | +| ISD | Inter-Site Distance | +| ITU | International Telecommunications Union | +| KPI | Key Performance Indicator | +| LCM | Life Cycle Management | +| LDPC | Low-Density Parity-Check | +| LLS | Lower Layer Split | +| LTE | Long Term Evolution | +| LVM | Logic Volume Manager | +| MEC | Mobile Edge Computing | +| mMTC | massive Machine Type Communications | +| MNO | Mobile Network Operator | +| NF | Network Function | +| NFD | Node Feature Discovery | +| NFVI | Network Function Virtualization Infrastructure | +| NIC | Network Interface Card | + +| | | | +|-----|-------------|-------------------------------------------------| +| 404 | NMS | Network Management System | +| 405 | NR | New Radio | +| 406 | NSA | Non-Standalone | +| 407 | NTP | <b>Network Time Protocol</b> | +| 408 | NUMA | Non-Uniform Memory Access | +| 409 | NVMe | Non-Volatile Memory Express | +| 410 | O-Cloud | O-RAN Cloud Platform | +| 411 | OCP | Open Compute Project | +| 412 | O-CU | O-RAN Central Unit | +| 413 | O-CU-CP | O-CU Control Plane | +| 414 | O-CU-UP | O-CU User Plane | +| 415 | O-DU | O-RAN Distributed Unit (uses Lower-level Split) | +| 416 | O-RU | O-RAN Radio Unit | +| 417 | OTII | Open Telecom IT Infrastructure | +| 418 | OWD | One-Way Delay | +| 419 | PCI | Peripheral Component Interconnect | +| 420 | PNF | Physical Network Function | +| 421 | PoE | Power over Ethernet | +| 422 | PoP | Point of Presence | +| 423 | PRTC | <b>Primary Reference Time Clock</b> | +| 424 | PTP | Precision Time Protocol | +| 425 | QoS | Quality of Service | +| 426 | RAN | Radio Access Network | +| 427 | RAT | Radio Access Technology | +| 428 | RIC | RAN Intelligent Controller | +| 429 | RT | Real Time | +| 430 | RTT | Round Trip Time | +| 431 | RU | Radio Unit | +| 432 | SA | Standalone | +| 433 | SFC | Service Function Chaining | +| 434 | SMO | Service Management and Orchestration | +| 435 | SMP | Symmetric MultiProcessing | +| 436 | SoC | System on Chip | +| 437 | SR-IOV | Single Root Input/ Output Virtualization | +| 438 | SW | Software | +| 439 | TCO | Total Cost of Ownership | +| 440 | TNE | Transport Network Element | +| 441 | TR | Technical Report | +| 442 | TRP | Transmission Reception Point | +| 443 | TS | Technical Specification | +| 444 | TSC (T-TSC) | Telecom Slave Clock | +| 445 | Tx | Transmitter | +| 446 | UE | User Equipment | +| 447 | UL | Uplink | +| 448 | UMTS | Universal Mobile Telecommunications System | +| 449 | UP | User Plane | +| 450 | UPF | User Plane Function | +| 451 | URLLC | Ultra-Reliable Low-Latency Communications | +| 452 | vCPU | virtual CPU | +| 453 | VIM | Virtualized Infrastructure Manager | +| 454 | VM | Virtual Machine | +| 455 | VNF | Virtualized Network Function | +| 456 | vO-CU | Virtualized O-RAN Central Unit | +| 457 | vO-CU-CP | Virtualized O-CU Control Plane | +| 458 | vO-CU-UP | Virtualized O-CU User Plane | +| 459 | vO-DU | Virtualized O-RAN Distributed Unit | + +# 4 Overall Architecture + +This section addresses the overall architecture in terms of the Network Functions and infrastructure (O-RAN Physical NFs, servers, and clouds) that are in scope. Figure 4 provides a high-level view of the O-RAN architecture as depicted in [10]. + +![Figure 4: High Level Architecture of O-RAN. The diagram shows the Service Management and Orchestration Framework (SMO) at the top, connected to the Non-RT RIC. The Non-RT RIC is connected to the Near-RT RIC via the A1 interface. The Near-RT RIC is connected to the O-RAN Network Functions via the O1 interface. The O-RAN Network Functions are connected to the O-Cloud via the O-Cloud Notification interface. The O-Cloud is connected to the O-RU via the Open Fronthaul M-Plane. The O-RU is connected to the NG-Core via the NG interface. An external system provides enrichment data to the SMO. A legend indicates that purple lines represent O-RAN Defined Interfaces, orange lines represent 3GPP Defined Interfaces, and black lines represent interfaces out of scope for O-RAN.](2316693227d23dbe64b1b40a4f608857_img.jpg) + +Figure 4: High Level Architecture of O-RAN. The diagram shows the Service Management and Orchestration Framework (SMO) at the top, connected to the Non-RT RIC. The Non-RT RIC is connected to the Near-RT RIC via the A1 interface. The Near-RT RIC is connected to the O-RAN Network Functions via the O1 interface. The O-RAN Network Functions are connected to the O-Cloud via the O-Cloud Notification interface. The O-Cloud is connected to the O-RU via the Open Fronthaul M-Plane. The O-RU is connected to the NG-Core via the NG interface. An external system provides enrichment data to the SMO. A legend indicates that purple lines represent O-RAN Defined Interfaces, orange lines represent 3GPP Defined Interfaces, and black lines represent interfaces out of scope for O-RAN. + +Figure 4: High Level Architecture of O-RAN + +## 4.1 O-RAN Functions Definitions + +This section reviews key O-RAN functions definitions in O-RAN. + +- The O-DU/ O-RU split is defined as using Option 7-2x. See [7]. +- The O-CU/ O-DU split is defined as using the CU/ DU split F1 as defined in 3GPP TS 38.470 [1]. + +This document assumes these two splits. + +Figure 5 shows the logical architecture of O-RAN (as depicted in [10]) with O-Cloud platform at the bottom, where any given O-RAN function could be supported by O-Cloud, depending on the deployment scenario. For example, the figure here illustrates a case where the O-RU is implemented as an O-RAN Physical NF, and the other functions within the dashed line are supported by O-Cloud. + +![Figure 5: Logical Architecture of O-RAN. The diagram shows a hierarchical architecture. At the top is the 'Service Management and Orchestration Framework' (purple box) containing a 'Non-Real Time RIC' (green box). Below it is the 'Near-Real Time RAN Intelligent Controller (RIC)' (blue box). To the left is an 'O-eNB' (green box). In the center are 'O-CU-CP' and 'O-CU-UP' (yellow boxes). Below these are 'O-DU' and 'O-RU' (red boxes). At the bottom is the 'O-Cloud' (green box). Interfaces are labeled: O1, O2, A1, E1, E2, F1-c, F1-u, X2-c, X2-u, NG-u, Xn-c, NG-c. The 'Open Fronthaul M-Plane' is indicated between the RIC and the DU/Cloud layers. The 'OFH CUS-Plane' and 'OFH M-Plane' are indicated between the DU and RU layers.](9f1ec8232712fd5ba7a9c3bb7bf02b05_img.jpg) + +Figure 5: Logical Architecture of O-RAN. The diagram shows a hierarchical architecture. At the top is the 'Service Management and Orchestration Framework' (purple box) containing a 'Non-Real Time RIC' (green box). Below it is the 'Near-Real Time RAN Intelligent Controller (RIC)' (blue box). To the left is an 'O-eNB' (green box). In the center are 'O-CU-CP' and 'O-CU-UP' (yellow boxes). Below these are 'O-DU' and 'O-RU' (red boxes). At the bottom is the 'O-Cloud' (green box). Interfaces are labeled: O1, O2, A1, E1, E2, F1-c, F1-u, X2-c, X2-u, NG-u, Xn-c, NG-c. The 'Open Fronthaul M-Plane' is indicated between the RIC and the DU/Cloud layers. The 'OFH CUS-Plane' and 'OFH M-Plane' are indicated between the DU and RU layers. + +Figure 5: Logical Architecture of O-RAN + +## 4.2 Degree of Openness + +In theory, every architecture component could be open in every sense imaginable, but in practice it is likely that different components will have varying degrees of openness due to economic and other implementation considerations. Some factors are significantly affected by the deployment scenario; for example, what might be viable in an indoor deployment might not be viable in an outdoor deployment. + +Increasing degrees of openness for an O-RAN Physical Network Function or O-RAN Cloudified Network Function(s) are: + +- A. Interfaces among Network Functions are open, e.g., E2, F1, and Open Fronthaul are used. Therefore, Network Functions in different O-RAN Physical NFs/clouds from different vendors can interconnect. +- B. In addition to having open connections as described above, the chassis of servers in a cloud are open and can accept blades/sleds from multiple vendors. However, the blades/sleds have RAN software that *is not* decoupled from the hardware. +- C. In addition to having open connections and an open chassis, a specific blade/sled uses software that *is* decoupled from the hardware. In this scenario, the software could be from one supplier, the blade/sled could be from another, and the chassis could be from another. + +Categories A and B have O-RAN Physical NFs/clouds, while Category C is an open solution that we are calling an O-Cloud and is subject to the cloudification discussion and requirements. + +In this document, the degree of openness for each O-RAN Physical NF/cloud can vary by scenario. The question of which Network Functions should be split vs. combined, and the degree of openness in each one, is addressed in the discussion of scenarios. + +## 4.3 Decoupling of Hardware and Software + +*Editor's note: O-RU AAL is a future study item.* + +There are three layers that we must consider when we discuss decoupling of hardware and software: + +- The hardware layer, shown at the bottom in Figure 6. (In the case of a VM deployment, this maps basically to the ETSI NFVI hardware sub-layer.) +- A middle layer that includes Cloud Stack functions as well as Acceleration Abstraction Layer functions. (In the case of a VM deployment, these map to the ETSI NFVI virtualization sub-layer + VIM.) + +- A top layer that supports the virtual RAN functions. + +Each layer can come from a different supplier. The first aspect of decoupling has to do with ensuring that a Cloud Stack can work on multiple suppliers' hardware, i.e., it does not require vendor-specific hardware. + +The second aspect of decoupling has to do with ensuring that a Cloud Platform can support RAN virtualized functions from multiple RAN software suppliers. If this is possible, then we say that the Cloud Platform (which includes the hardware that it runs on) is an O-RAN Cloud Platform, or "O-Cloud". See Figure 6 below. + +![Figure 6: Decoupling, and Illustration of the O-Cloud Concept. The diagram shows a layered architecture. At the top, three green boxes represent O-CU, O-DU, and O-RU. Below these, three orange boxes represent AAL (Application and Adaptation Layer). These AAL boxes sit on top of a large orange box labeled 'Cloud stack (Containers/VMs, OS, Cloud Mgmt.)'. This entire stack is enclosed in a blue bracket labeled 'O-Cloud'. Below the Cloud stack, four hardware components are shown: a blue 'x86' processor, an orange 'FPGA' (Field-Programmable Gate Array), a green 'GPU' (Graphics Processing Unit), and a yellow 'ASIC' (Application-Specific Integrated Circuit). These hardware components are enclosed in a blue bracket labeled 'Hardware'. Dashed red lines separate the O-CU/O-DU/O-RU layer from the AAL layer, the AAL layer from the Cloud stack, and the Cloud stack from the Hardware layer.](41ebba9617dff91ac8d3573c71d5dab8_img.jpg) + +Figure 6: Decoupling, and Illustration of the O-Cloud Concept. The diagram shows a layered architecture. At the top, three green boxes represent O-CU, O-DU, and O-RU. Below these, three orange boxes represent AAL (Application and Adaptation Layer). These AAL boxes sit on top of a large orange box labeled 'Cloud stack (Containers/VMs, OS, Cloud Mgmt.)'. This entire stack is enclosed in a blue bracket labeled 'O-Cloud'. Below the Cloud stack, four hardware components are shown: a blue 'x86' processor, an orange 'FPGA' (Field-Programmable Gate Array), a green 'GPU' (Graphics Processing Unit), and a yellow 'ASIC' (Application-Specific Integrated Circuit). These hardware components are enclosed in a blue bracket labeled 'Hardware'. Dashed red lines separate the O-CU/O-DU/O-RU layer from the AAL layer, the AAL layer from the Cloud stack, and the Cloud stack from the Hardware layer. + +Figure 6: Decoupling, and Illustration of the O-Cloud Concept + +### 4.3.1 The O-Cloud + +The general definition of the O-Cloud Platform includes the following characteristics: + +- The O-Cloud Platform is a set of hardware and software components that provide O-Cloud Capabilities and services to execute RAN network functions. +- The O-Cloud Platform hardware includes compute, networking and storage components, and can also include various acceleration technologies required by the RAN network functions to meet their performance objectives. +- The O-Cloud Platform software exposes open and well-defined APIs that enable the orchestration and management of the NF Deployment's life cycle. +- The O-Cloud Platform software exposes open and well-defined APIs that enable the orchestration and management of the O-Cloud. +- The O-Cloud Platform software is decoupled from the O-Cloud Platform hardware (i.e., it can typically be sourced from different vendors). + +The management aspects of the O-Cloud Platform are discussed in 5.6. The scope of the present document includes listing specific requirements of the O-Cloud Platform to support orchestration and execution of the various O-RAN Network Functions. + +An example of an O-Cloud Platform is an OpenStack and/or a Kubernetes Cluster deployment on a set of COTS servers (including FPGA and GPU cards), interconnected by a spine/leaf networking fabric. + +There is an important interplay between specific virtualized RAN functions and the hardware that is needed to meet performance requirements and to support the functionality *economically*. Therefore, a hardware/ cloud platform combination that can support, say, a vO-CU function might not be appropriate to adequately support a vO-DU function. When RAN functions are combined in different ways in each specific deployment scenario, these aspects must be considered. + +Such infrastructure requirements of the Cloudified NFs and/or their constituent NF Deployments are among the Service Management and Orchestration (SMO) considerations for the homing decision. The SMO is responsible to make the homing decision, which results in the SMO selection of the appropriate O-Cloud Node Cluster(s) matching the requested capabilities for the NF Deployment(s) and makes the determination of the specific Deployment Management Service (DMS) that the SMO deems adequate for an NF Deployment. + +The O-Cloud DMS(s) is responsible to decide on the placement of the workloads for an NF Deployment, internally inside the O-Cloud Node Cluster(s) based on the SMO’s homing decision and using other NF Deployment requirements that it receives through the O2dms. + +Below is a high-level conceptual example of how different accelerators, along with their associated O-Cloud Capabilities, can be required for different RAN functions. Although the present document does not specify any particular hardware requirement or O-Cloud Capability, some specific examples can be devised. For example, any RAN function that involves real-time movement of user traffic might require the O-Cloud Platform to control for delay and jitter, which can in turn require features such as real-time OSs, avoidance of frequent interrupts, CPU pinning, etc. + +![Figure 7: Relationship between RAN Functions and Demands on Cloud Infrastructure and Hardware. The diagram shows a network architecture flow: UPF,MEC connects to Near-RT RIC via E2. Near-RT RIC connects to O-CU-CP via E1. O-CU-CP connects to O-CU-UP via E1. O-CU-UP connects to O-DU via F1-c and F1-u. O-DU connects to O-RU via Open fronthaul.](338e65a06e4e9d8d1d7acdaa59bbb3bf_img.jpg) + +Figure 7: Relationship between RAN Functions and Demands on Cloud Infrastructure and Hardware. The diagram shows a network architecture flow: UPF,MEC connects to Near-RT RIC via E2. Near-RT RIC connects to O-CU-CP via E1. O-CU-CP connects to O-CU-UP via E1. O-CU-UP connects to O-DU via F1-c and F1-u. O-DU connects to O-RU via Open fronthaul. + +| Cloud/ HW features | Near-RT RIC | O-CU-CP | O-CU-UP | O-DU | O-RU | +|----------------------------------------------------------|-------------|---------|---------|------|------| +| Standard Cloud Infrastructure (CI) & General Purpose CPU | ✓ | ✓ | | | | +| CI + high speed UP support. Acceleration optional | | | ✓ | | | +| CI + high speed UP, acceleration for O-DU | | | | ✓ | | +| CI + high speed UP, acceleration for O-RU | | | | | ✓ | + +**Figure 7: Relationship between RAN Functions and Demands on Cloud Infrastructure and Hardware** + +Finally, it is to be highlighted, that any cloud that has features required for a given function (e.g., for O-DU) can also support functions that do not require such features. For example, an O-Cloud that can support O-DU can also support functions such as O-CU-CP. + +### 4.3.2 Key O-Cloud Concepts + +Figure 8 illustrates key components of an O-Cloud and its management. + +![Figure 8: Key Components Involved in/with an O-Cloud. The diagram illustrates the architecture of an O-Cloud, showing its interaction with a Service Management & Orchestration Framework (SMO) and its internal components across multiple sites.](8df8301d88ae3746ee7c9d8fc48df1cd_img.jpg) + +The diagram illustrates the architecture of an O-Cloud, showing its interaction with a Service Management & Orchestration Framework (SMO) and its internal components across multiple sites. + +**Service Management & Orchestration Framework (SMO):** Located at the top, it interacts with the O-Cloud via **O2ims** and **O2dms** interfaces. + +**O-Cloud Architecture:** + +- Infrastructure Management Services (Logical & Distributed) [1]:** A yellow block at the top of the O-Cloud stack. +- Deployment Management Services (Logical & Distributed) [1..n]:** A blue block below the IMS, containing **DMS 1** and **DMS n**. +- Deployment Plane (Logical):** A blue block containing **NF Deployment** and **NF Part Deployment** components. +- Node Clusters:** Below the deployment plane, there are **Node Cluster<sub>1</sub>**, **Node Cluster<sub>2</sub>**, and **Distributed Node Cluster<sub>n</sub>**. Each cluster contains **Node Group** and **Node Group Site NW** components. +- Resource Pools:** Below the node clusters, there are **Resource Pool<sub>1</sub>**, **Resource Pool<sub>2</sub>**, **Resource Pool<sub>3</sub>**, **Resource Pool<sub>4</sub>**, and **Resource Pool<sub>m</sub>**. Each pool contains **Compute** and **Storage** components. +- O-Cloud Site:** The bottom section of the O-Cloud stack, containing **Compute1**, **Storage1**, **Site Network**, **Site Network Fabric**, **Gateway**, and **VRF** components. + +**Distributed across multiple locations:** The O-Cloud architecture is distributed across multiple locations, as indicated by the **O-Cloud Site** and **Resource Pools** being repeated across different sites. + +Figure 8: Key Components Involved in/with an O-Cloud. The diagram illustrates the architecture of an O-Cloud, showing its interaction with a Service Management & Orchestration Framework (SMO) and its internal components across multiple sites. + +**Figure 8: Key Components Involved in/with an O-Cloud** + +Key terms in this figure are defined below: + +- The SMO is defined in [10]. +- An **O-Cloud** refers to a collection of O-Cloud Resources, Resource Pools and O-Cloud Services at one or more O-Cloud Sites including the software to manage O-Cloud Resource provisioning, Nodes, Clusters and Deployments hosted on them. An O-Cloud will include functionality to support both Deployment-plane (aka. user-plane) and Management services. The O-Cloud provides a single logical reference point for all O-Cloud Resources, Resource Pools and Services within the O-Cloud boundary, i.e. for the distributed O-Cloud. +- An **O-Cloud Site** refers to a set of O-Cloud Resources at a Cloud Site with a geographical location. The size of the O-Cloud Site can be from a single to thousands of O-Cloud Resources. O-Cloud Resources are generally interconnected through one or more O-Cloud Site Network Fabrics that are the demarcation for direct O-Cloud Site internal L2 switching. Multiple O-Cloud Sites can be interconnected into a distributed O-Cloud which generally would require bridging, routing or stitching on any other networking layer in between each O-Cloud Site and its respective external transport network attachment point. + - NOTE: Very small O-Cloud Sites with just a few O-Cloud Resources can be directly connected to networks outside of the O-Cloud Site, supporting e.g. fronthaul and backhaul networks, without an O-Cloud Site Network Fabric. +- The **O2 Interfaces** are the interfaces associated with a collection of O-Cloud Services that are provided by the O-Cloud platform to the SMO. The services are categorized into two logical groups: (i) **Infrastructure Management Services (IMS)**, which include the subset of O2 functions that are responsible for deploying and managing cloud infrastructure. (ii) **Deployment Management Services (DMS)**, which include the subset of O2 functions that are responsible for managing the lifecycle of virtualized/containerized deployments on the cloud infrastructure. The O2 interfaces associated with the O-Cloud Infrastructure and Deployment Management Services will be specified in the upcoming O2 specification. Any definitions of SMO functional elements needed to consume these services shall be described in OAM architecture. Further details of these key concepts and how they relate to each other can be found in the O-RAN O2 Interface General Aspects and Principles (GANP). +- O-Cloud IMS related concepts and views of the Cloud Infrastructure + - An **O-Cloud Resource** represent a unit of defined capabilities and characteristics within an O-Cloud Cloud Site that can be provisioned and used for the O-Cloud Deployment Plane. There are some + +- different sorts of O-Cloud Resources e.g. Compute, HW-Accelerator, Storage, Gateway and Site Network Fabric. Note: Exact classes of O-Cloud Resources are FFS and needs alignment to existing other specifications e.g. GANP and IMS Interface Specification. +- An **O-Cloud Resource Pool** is a collection of O-Cloud Resources with homogeneous capabilities and characteristics as defined by the operator within an O-Cloud Site. + - The **Unspecified O-Cloud Resource Pool** is the collection of O-Cloud Resources that are exposed in the O-Cloud IMS inventory without a classification or being placed in any O-Cloud Resource Pool. Note: Exact classes of O-Cloud Resources are FFS. + - An **O-Cloud Site Network Fabric** is an O-Cloud Resource that connects the O-Cloud Resources that can connect to other O-Cloud Resources in an O-Cloud Site. + - An **O-Cloud Site Network** is a provisioned Network Resource with its configured defined capabilities and characteristics out of an O-Cloud Site Network Fabric. +- O-Cloud DMS related concepts and views of the O-Cloud Resources that are created/updated through IMS provisioning + - **O-Cloud Deployment Plane** is a logical construct representing the O-Cloud Nodes, O-Cloud Networks and O-Cloud Node Clusters which are used to create NF Deployments. The O-Cloud Deployment Plane is created using IMS provisioned O-Cloud Resources from O-Cloud Resource Pools and O-Cloud Site Network Fabrics. + - **NF Deployment**, see term definition in 3.1. + - An **O-Cloud Node** is a network connected (physical and/or logical) computer or a network connection terminating function. An O-Cloud Node can be provisioned by the IMS into the O-Cloud Node Cluster. O-Cloud Nodes are typically comprised of physical and/or logical CPUs, Memories, Storages, NICs, HW Accelerators, etc. and a loaded Operating System with relevant Cluster SW. The O-Cloud Node software discovers, abstracts and exposes the IMS-assigned O-Cloud Resources or partitions of them as O-Cloud Deployment Plane constructs. Note that an O-Cloud Node could also exist as a stand-alone O-Cloud Node. + - An **O-Cloud Node Cluster** is a collection of O-Cloud Nodes that work in concert with each other, through a set of interconnecting O-Cloud Node Cluster Site Networks. The O-Cloud Nodes Operating System and Cluster SW discover its capabilities, characteristics and initial parameters with additional configuration done through the IMS. The cluster concepts will be further specified in the GANP document. + - An **O-Cloud Node Cluster Site Network** is an O-Cloud Site Network assigned to an O-Cloud Node Cluster. + - An **O-Cloud Node Group** is a set of O-Cloud Nodes within an O-Cloud Node Cluster that are to be treated as equal by some aspects e.g., the O-Cloud Node Cluster scheduler. These O-Cloud Nodes are interconnected through the set of O-Cloud Node Cluster Site Networks and an optional set of O-Cloud Node Group Site Networks. These O-Cloud Nodes would commonly have similar capabilities and characteristics exposed from their set of used computational, storage and networking Resources. + - An **O-Cloud Node Group Site Network** is an O-Cloud Site Network assigned to an O-Cloud Node Group in a O-Cloud Node Cluster. + - An **O-Cloud Distributed Node Cluster Network** is a logical network that spans across multiple O-Cloud Sites. It is realized by connecting multiple O-Cloud Node Cluster Site Networks in O-Cloud Sites through transport network(s). + +Figure 9 illustrates an example of how O-Cloud Resources and parts of O-Cloud Resources are mapped into O-Cloud Nodes and O-Cloud Node Clusters which is done through the O-Cloud IMS Provisioning services. The depicted O-Cloud Node Groups and their related O-Cloud Node Group Site Networks are dashed to indicate that this grouping level is optional. + +![Figure 9: Example of O-Cloud Resources mapped to O-Cloud Nodes and O-Cloud Networks in an O-Cloud Node Cluster. The diagram shows a hierarchical architecture. At the top is the 'Service Management & Orchestration Framework' (purple) with 'O2ims' and 'O2dms' interfaces. Below is the 'O-Cloud' layer (green) containing 'Infrastructure Management Services (Logical & Distributed)' (yellow), 'Deployment Management Services (Logical & Distributed) [1..n]' (blue), and 'Deployment Plane (Logical)' (blue). The 'Deployment Plane' includes 'NF Deployment' and 'NF Part Deployment' blocks. Below these are 'Node' blocks, which are grouped into 'Node Group' and 'Node Cluster' structures. These are mapped to 'Resource Pools' (yellow) containing 'Compute' (including disks and PCI cards), 'HW-Acc' (hardware accelerators), and 'Storage' resources. The 'Node Cluster' is further mapped to 'Site Network' and 'Site Network Fabric' resources, which are connected to a 'Gateway' block containing 'VRF' (Virtual Routing and Forwarding) resources. Dashed lines indicate the mapping and connectivity between these layers.](6200e43fb3139bbc5f2e5bbdee5c333b_img.jpg) + +Figure 9: Example of O-Cloud Resources mapped to O-Cloud Nodes and O-Cloud Networks in an O-Cloud Node Cluster. The diagram shows a hierarchical architecture. At the top is the 'Service Management & Orchestration Framework' (purple) with 'O2ims' and 'O2dms' interfaces. Below is the 'O-Cloud' layer (green) containing 'Infrastructure Management Services (Logical & Distributed)' (yellow), 'Deployment Management Services (Logical & Distributed) [1..n]' (blue), and 'Deployment Plane (Logical)' (blue). The 'Deployment Plane' includes 'NF Deployment' and 'NF Part Deployment' blocks. Below these are 'Node' blocks, which are grouped into 'Node Group' and 'Node Cluster' structures. These are mapped to 'Resource Pools' (yellow) containing 'Compute' (including disks and PCI cards), 'HW-Acc' (hardware accelerators), and 'Storage' resources. The 'Node Cluster' is further mapped to 'Site Network' and 'Site Network Fabric' resources, which are connected to a 'Gateway' block containing 'VRF' (Virtual Routing and Forwarding) resources. Dashed lines indicate the mapping and connectivity between these layers. + +**Figure 9: Example of O-Cloud Resources mapped to O-Cloud Nodes and O-Cloud Networks in an O-Cloud Node Cluster** + +An O-Cloud Resource Pool comprises one or more O-Cloud Resources, each with one or more network connections and optionally, one or more internal HW accelerators and storage devices. The O-Cloud Site Network Fabric Resources may provide connectivity between the pooled O-Cloud Resources of O-Cloud Compute, O-Cloud HW-Accelerator, O-Cloud Storage and O-Cloud Gateway Resources, and to the O-RU through an O-RAN 7.2x compliant Fronthaul transport. The O-Cloud Gateways may bridge or stitch O-Cloud Site Networks across multiple O-Cloud Resource Pools in different Cloud Sites inside a distributed O-Cloud. The O-Cloud Site Network Fabrics are managed by the Infrastructure Management Services (IMS) described earlier. Interconnection of the different O-Cloud Sites in a distributed O-Cloud is typically done through an externally provisioned and managed WAN Transport but could also be done through Cloud Infrastructure internally managed WAN Transport. Figure 10 shows an example of the architecture and usage of one or more O-Cloud Compute Resource Pools, comprising multiple servers interconnected over an O-Cloud Site Network Fabric. + +Image: O-RAN Alliance Logo + +**O-RAN.WG6.CADS-v08.01 TR** +![Figure 10: Edge O-Cloud Site deployment example with an O-Cloud Site Network Fabric (Hub)](23f9a125c64b34a81f0d4f75fc63e164_img.jpg) + +Detailed description of Figure 10: The diagram shows the SMO (Service Management and Orchestration) at the top, connected via O2ims and O2dms interfaces to the IMS and DMS within the Edge O-Cloud Site. The DMS manages O-Cloud Node Clusters containing Servers with Node OS, Acc, and NIC. These servers are part of the O-Cloud Resource Pool(s). Below the servers is the O-Cloud Site Network Fabric containing Leaf and Spine (optional) switches. This fabric connects to the Fronthaul transport (O-RU: PHY-low/RF via O-RAN 7.2x FH) and to the Backhaul or midhaul transport (which can connect to Regional O-Cloud Sites). A Time source (GNSS) is also connected to the fabric. + +Figure 10: Edge O-Cloud Site deployment example with an O-Cloud Site Network Fabric (Hub) + +**Figure 10: Edge O-Cloud Site deployment example with an O-Cloud Site Network Fabric (Hub)** + +An O-Cloud Resource Pool may also comprise one or a set of single servers without any associated O-Cloud Site Network Fabric, e.g., infrastructure deployed at a cell site. In such a scenario where an O-Cloud Site Network Fabric is not present, the O-Cloud Compute Resources may be directly connected to the O-RU through an O-RAN compliant front haul connection and to an externally provisioned backhaul or midhaul Transport. Figure 11 shows an example of the architecture and usage of an O-Cloud Compute Resource Pool in such a configuration without the O-Cloud Site Network Fabric. + +![Figure 11: Edge O-Cloud Site deployment example without an O-Cloud Site Network Fabric (Single servers)](e891944b37f286de820c361071556461_img.jpg) + +Detailed description of Figure 11: This diagram is similar to Figure 10 but lacks the O-Cloud Site Network Fabric (Leaf and Spine switches). Instead, the Servers (with Node OS, Acc, NIC) in the O-Cloud Node Clusters are directly connected to the Fronthaul transport (O-RU: PHY-low/RF) and to the Backhaul or midhaul transport. + +Figure 11: Edge O-Cloud Site deployment example without an O-Cloud Site Network Fabric (Single servers) + +**Figure 11: Edge O-Cloud Site deployment example without an O-Cloud Site Network Fabric (Single servers)** + +Copyright © 2025 by the O-RAN Alliance e.V. Your use is subject to the copyright statement on the cover page of this specification. + +19 + +The requirements on the O-Cloud Site Network Fabric such as clock/sync requirements, latency and jitter recommendations shall be described in a future version of this document. We note that the architecture of a regional cloud may be similar to that of an edge cloud but may not include some requirements such as time source. + +### 4.3.3 O-Cloud Platform Management Functionalities + +An O-Cloud Platform can provide a degree of automation and autonomous handling of its functionalities (including DMS and IMS). In such cases, the O-Cloud Platform can detect, trigger and handle autonomously and without any SMO intervention, tasks with a certain level of complexity. An example is an O-Cloud Platform based on Kubernetes® (as specified by the CNCF®), where this O-Cloud Platform is capable of placing the workloads (for NF Deployments) on suitable O-Cloud Nodes based on deployment artifacts and orchestration policies, as well as detect, trigger and execute O-Cloud Node self-repair, or to execute autonomously a horizontal auto-scaling of running workloads for the NF Deployments based on the scaling data made available in the deployment artifacts. + +Examples of the main tasks that the DMS handles based on the information received over O2dms, includes (non-exhaustive list): + +- The placement of the workloads for O-RAN NF Deployments, internally within the O-Cloud Node Cluster(s); +- The LCM of the respective workloads, including: + - o The allocation of resources inside the O-Cloud Node Clusters that the workloads will run on, + - o the configuration of the allocated resources as needed for the deployment (e.g., IP addresses, connection points, etc). + - o The execution, either autonomously/automatically or on-demand, of any necessary workload LCM operations within the allocated O-Cloud Node Cluster, such as scaling out/in, or self-healing. + - o The move of NF Deployment workloads in different O-Cloud Nodes within the same O-Cloud Node Cluster when errors in the allocated resources fail to meet the expected service levels previously indicated over O2dms, + - o The termination of the deployment of NF Deployments when requested by SMO over O2dms, +- The updates to the O-Cloud inventory with latest status information about O-Cloud resources used for NF Deployment workloads that it lifecycle manages. + +Example of main tasks (non-exhaustive list) that the IMS handles based on the information received over O2ims: + +- Provisioning requests for the O-Cloud Node Clusters, with an allocation of resources and their configuration. The main task is to keep track of available resources, their capabilities, their capacities and to allocate them into the SMO requested Node Clusters with appropriate configuration that makes the Node Clusters usable for the NF Deployments. + - o The Node Cluster and Resource capabilities and capacities, along with the resulting mapping of Node Clusters to Resources, are exposed over the O2ims inventory service. +- Fault management of the O-Cloud Node Clusters and O-Cloud Resources that will limit the O-Cloud total capabilities and capacities. Alarms are available for SMO consumption over the O2ims interface with relevant information about the faults. +- Performance management and reporting of the O-Cloud Node Clusters and O-Cloud Resources. The measurements are available for SMO consumption over the O2ims interface with relevant information about the measurements. +- O-Cloud inventory reporting, exposed via O2ims inventory services, of the O-Cloud Sites, Deployment Management Services, Node Clusters and Resources including their capabilities, capacities, allocations, and availabilities that enables the SMO to understand how requested allocations have been met by the O-Cloud and what the O-Cloud available capabilities and capacities are. O-Cloud life cycle management, where the O-Cloud infrastructure management Services, Sites, Deployment Manager Services and Resources are registered, structured and configured to have agreed settings and API versions for O2ims communication with SMO. +- Performing maintenance operations in the O-Cloud Platform, either autonomously/automatically or on demand, e.g., switching the operational mode of O-Cloud Node(s) into the maintenance mode when an O-Cloud Node within an O-Cloud Node Cluster requires maintenance or is scheduled for decommissioning. + +## 4.4 O-Cloud Multi-Site Networking + +For disaggregated O-RAN deployments, the Network Functions (VNFs/ CNFs) may be deployed in multiple O-Clouds or O-Cloud sites. These sites or O-Clouds are generally interconnected via Transport Networks. + +For these disaggregated NFs to communicate with each other, end-to-end connectivity needs to be established, which includes networking within O-Cloud site and as well Transport Network as shown in the figure below. + +![Figure 4.4-1: Logical view of multi-site connectivity through Transport Network. The diagram shows two O-Cloud Sites connected via a central Transport Network. Each O-Cloud Site contains an O-CLOUD GW and NF(S). The O-Cloud Site Network connects the NF(S) to the O-CLOUD GW. The Transport Network connects the O-CLOUD GW of one site to the O-CLOUD GW of another site via TNE (Transport Network Element).](df13dcad8b8ab6a9e28e485c8fdee29b_img.jpg) + +``` + +graph LR + subgraph O-Cloud_Site_1 [O-Cloud Site] + NF1[NF(S)] + subgraph Site_Fabric [Site Fabric] + NF1 + end + OCGW1[O-CLOUD GW] + NF1 --- Site_Fabric + Site_Fabric --- OCGW1 + end + subgraph Transport_Network [Transport Network] + TNE1[TNE] + TNE2[TNE] + OCGW1 --- TNE1 + TNE2 --- OCGW2 + end + subgraph O-Cloud_Site_2 [O-Cloud Site] + OCGW2[O-CLOUD GW] + NF2[NF(S)] + OCGW2 --- NF2 + end + OCGW1 --- TNE1 + TNE2 --- OCGW2 + +``` + +Figure 4.4-1: Logical view of multi-site connectivity through Transport Network. The diagram shows two O-Cloud Sites connected via a central Transport Network. Each O-Cloud Site contains an O-CLOUD GW and NF(S). The O-Cloud Site Network connects the NF(S) to the O-CLOUD GW. The Transport Network connects the O-CLOUD GW of one site to the O-CLOUD GW of another site via TNE (Transport Network Element). + +**Figure 4.4-1: Logical view of multi-site connectivity through Transport Network** + +O-Cloud Site Network connects the NFs to the O-Cloud Gateway. If an O-Cloud site has a site fabric, this connectivity is achieved through the fabric. This connectivity is local within O-Cloud site. However, the connectivity between the O-Cloud Gateway and Transport Network Element (TNE) (a.k.a. Transport Endpoint) needs to be established to achieve end-to-end connectivity. + +### 4.4.1 O-Cloud and Transport Network Shared Connectivity Information + +O-Cloud and Transport Networks generally belong to different administrative domains and are orchestrated independently; hence a mechanism is needed to orchestrate the connectivity between the O-Cloud Gateway and the Transport Network Element. + +The subnet between the O-Cloud gateway and the TNE needs to be configured with appropriate Identifiers (such as VLAN ID, subnet CIDR, Gateway IP). These identifiers must match on both sides of the administrative domains to achieve successful configuration of the subnet. Hence, an appropriate mechanism is needed so that these identifiers can be exchanged to allow each side independently to configure their side of the subnet. + +Depending upon the deployment scenarios, the operators may make the choice as to which domain will manage the selection and allocation of these identifiers. For instance, if O-Cloud is the manager for the allocation of these identifiers, it will first configure the O-Cloud gateway port connecting to the TNE. These identifiers are then passed to the Transport Network domain to configure the TNE port that connects to the O-Cloud gateway. + +Conversely, if Transport Network Domain is the manager for allocation of these identifiers, the TNE is configured first and then the identifiers are passed to the O-Cloud. + +# 5 Deployment Scenarios: Common Considerations + +In any implementation of logical network functionality, decisions need to be made regarding which logical functions are mapped to which Cloud Platforms, and therefore which functions are to be co-located with other logical functions. In this document we do not prescribe one specific implementation, but we do understand that in order to establish agreements and requirements, the manner in which the Network Functions are mapped to the same or different Cloud Platforms must be considered. + +We refer to each specific mapping as a “deployment scenario”. In this section, we examine the deployment scenarios that are receiving the most consideration. Then we will select the one or ones that should be the focus of initial scenario reference design efforts. + +## 5.1 Mapping Logical Functionality to Physical Implementations + +There are many aspects that need to be considered when deciding to implement logical functions in distinct O-Clouds. Some aspects have to do with fundamental technical constraints and economic considerations, while others have to do with the nature of the services that are being offered. + +### 5.1.1 Technical Constraints that Affect Hardware Implementations + +Below are some factors that will affect the cost of implementations and can drive a carrier to require separation of or combining of different logical functions. + +- **Environment:** Equipment may be deployed in indoor controlled environments (e.g., Central Offices), semi-controlled environments (e.g., cabinets with fans and heaters), and exposed environments (e.g., Radio Units on a tower). In general, the less controlled the environment, the more difficult and expensive the equipment will be. The required temperature range is a key design factor and can drive higher power requirements. + - **Dimensions:** The physical dimensions can also drive deployment constraints – e.g., the need to fit into a tight cabinet, or to be placed safely on a tower or pole. + - **Transport technology:** The transport technology used for Fronthaul, Midhaul, and Backhaul is often fiber, which has an extremely low and acceptable loss rate. However, there are options other than fiber, in particular wireless/ microwave, where the potential for data loss must be considered. This will be discussed further in the next section. + - **Acceleration Hardware:** The need for acceleration hardware can be driven by the need to meet basic performance requirements but can also be tied to some of the above considerations. For example, a hardware acceleration chip (COTS or proprietary) can result in lower power use, less generated heat, and smaller physical dimensions than if acceleration is not used. On the other hand, some types of hardware acceleration chips might not be “hardened” (i.e., they might only operate properly in a restricted environment) and could require a more controlled environment such as in a central office. +- The acceleration hardware most often referred to includes: +- Field Programmable Gate Arrays (FPGAs) + - Graphical Processing Units (GPUs) + - System on Chip (SoC) + - **Standardized Hardware:** Use of standardized hardware designs and standardized form factors can have advantages such as helping to reduce operations complexity, e.g., when an operator makes periodic technology upgrades of selected components. An example would be to use an Open Compute Project (OCP) or Open Telecom IT Infrastructure (OTII) –based design. + +### 5.1.2 Service Requirements that Affect Implementation Design + +RANs can serve a wide range of services and customer requirements, and each market can drive some unique requirements. Some examples are below. + +- **Indoor or outdoor deployment:** Indoor deployments (e.g., in a public venue like a sports stadium, train station, shopping mall, etc.) often enjoy a controlled environment for all elements, including the Radio Units. This can improve the economics of some indoor deployment scenarios. The distance between Network Functions tends to be much lower, and the devices that support O-RU functionality may be much easier and cheaper to install and maintain. This can affect the density of certain deployments, and the frequency that certain scenarios are deployed. +- **Bands supported, and Macro cell vs. Small cell:** The choice of bands (e.g., Sub-6 GHz vs. mmWave) might be driven by whether the target customers are mobile vs. fixed, and whether a clear line of sight to the customer is available or is needed. The bands to be supported will of course affect O-RU design. In addition, because mmWave carriers can support much higher channel width (e.g., 400 MHz vs. 20 MHz), mmWave deployments can require a great deal more O-DU and O-CU processing power. And of course, the operations costs of deploying Macro cells vs. Small cells differ in other ways. +- **Performance requirements of the Application / Network Slice:** Ultimately, user applications drive performance requirements, and RANs are expected to support a very wide range of applications. For example, the delay requirements to support a Connected Car application using Ultra Reliable Low Latency + +Communications (URLLC) will be more demanding than the delay requirements for other types of applications. In our discussion of 5G, we can start by considering requirements separately for URLLC, enhanced Mobile Broadband (eMBB), and massive Machine Type Communications (mMTC). + +The consideration of performance requirements is a primary one and is the subject of Section 5.2. + +### 5.1.3 Rationalization of Centralizing O-DU Functionality + +Almost all Scenarios to be discussed in this document involve a degree of centralization of O-DU. In this section it is assumed that O-DU resources for a set of O-RUs are centralized at the same location. + +*Editor's Note: While most Scenarios also centralize O-CU-CP, O-CU-UP, and near-RT RIC in one form or another, the benefits of centralizing them are not discussed in this section.* + +Managing O-DU in equipment at individual cell sites (via on-site BBUs today) has multiple challenges, including: + +- If changes are needed at a site (e.g., adding radio carriers), then adding equipment is a coarse-grained activity – i.e., one cannot generally just add “another 1/5 of a box”, if that is all that is needed. Adding the minimum increment of additional capacity might result in poor utilization and thereby prevent expansion at that site. +- Cell sites are in many separate locations, and each requires establishment and maintenance of an acceptable environment for the equipment. In turn this requires separate visits for any physical operations. +- Micro sites tend to have much lower average utilization than macro sites, but each can experience considerable peaks. +- “Planned obsolescence” occurs, due to ongoing evolution of smartphone capabilities and throughput improvements, as well as introduction of new features and services. It is common practice today to upgrade (“forklift replace”) BBUs every 36-60 months. + +These factors motivate the centralization of resources where possible. For the O-DU function, we can think of two types of centralization: *simple* centralization and *pooled* centralization. + +If the equipment uses O-DU centralization in an Edge Cloud, at any given hour an O-RU will be using a single specific O-DU resource that is assigned to it (e.g., via Kubernetes). On a broad time scale, traffic from any cell site can be rehomed, without any physical work, to use other/additional resources that are available at that Edge Cloud location. This would likely be done infrequently, e.g., about as often as cell sites are expanded. + +Centralization can have some additional benefits, such as only having to maintain a single large controlled environment for many cell sites rather than creating and maintaining many distributed locations that might be less controlled (e.g., outside cabinets or huts). Capacity can be added at the central site and assigned to cell sites as needed. Note that *simple* centralization still assigns each O-RU to a single O-DU resource<sup>1</sup>, as shown below, and that traffic from one O-RU is not split into subsets that could be assigned to different O-DUs. Also note that a Fronthaul Gateway (FHGW)/Fronthaul Multiplexer (FHM) may exist between the cell site and the centralized resources, not only to improve economics but also to enable traffic re-routing when desired. + +![Diagram illustrating Simple Centralization of O-DU Resources. A box labeled 'O-Cloud at Edge' contains multiple O-DU blocks (O-DU #1, O-DU #2, ..., O-DU #n). These O-DU blocks are connected to a set of O-RU blocks (O-RU, O-RU, O-RU, O-RU, O-RU, ..., O-RU, O-RU) below. A bracket on the right side of the O-DU blocks is labeled 'Simple Centralization of Resources'.](746e4f6f1069e45b056e56f2178c6ef2_img.jpg) + +``` + +graph TD + subgraph OCloud [O-Cloud at Edge] + ODU1[O-DU #1] + ODU2[O-DU #2] + Dots1[...] + ODN[O-DU #n] + end + ODU1 --- ORU1[O-RU] + ODU1 --- ORU2[O-RU] + ODU2 --- ORU3[O-RU] + ODU2 --- ORU4[O-RU] + Dots1 --- Dots2[...] + ODN --- ORU5[O-RU] + ODN --- ORU6[O-RU] + subgraph ORUs [O-RU] + ORU1 + ORU2 + ORU3 + ORU4 + Dots2 + ORU5 + ORU6 + end + style OCloud fill:#fff,stroke:#333,stroke-width:1px + style ORUs fill:none,stroke:none + linkStyle 0,1,2,3,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60,61,62,63,64,65,66,67,68,69,70,71,72,73,74,75,76,77,78,79,80,81,82,83,84,85,86,87,88,89,90,91,92,93,94,95,96,97,98,99 stroke:#333,stroke-width:1px + +``` + +Diagram illustrating Simple Centralization of O-DU Resources. A box labeled 'O-Cloud at Edge' contains multiple O-DU blocks (O-DU #1, O-DU #2, ..., O-DU #n). These O-DU blocks are connected to a set of O-RU blocks (O-RU, O-RU, O-RU, O-RU, O-RU, ..., O-RU, O-RU) below. A bracket on the right side of the O-DU blocks is labeled 'Simple Centralization of Resources'. + +Figure 12: Simple Centralization of O-DU Resources + +<sup>1</sup> In this figure, each O-DU block can be thought of as a unit of server resources that includes a hardware accelerator, a GPP, memory and any other associated hardware. + +By comparison, with *pooled* centralization, traffic from an O-RU (or subsets of the O-RU's traffic) can be assigned more dynamically to any of several shared O-DU resources. So, if one cell site is mostly idle and another experiences high traffic demand, the traffic can be routed to the appropriate O-DU resources in the shared pool. The total resources of this shared pool can be smaller than resources of distributed locations, because the peak of the sum of the traffic will be markedly lower than the sum of the individual cell site traffic peaks. + +![Diagram illustrating the pooling of centralized O-DU resources. A box labeled 'O-Cloud at Edge' contains a blue cloud labeled 'O-DU Resources'. Below the cloud, several lines connect to labels 'O-RU', 'O-RU', 'O-RU', '...', and 'O-RU'. A bracket on the right side of the cloud is labeled 'Pooling of Centralized Resources'.](5394308b82aa861cc21518d87177972a_img.jpg) + +Diagram illustrating the pooling of centralized O-DU resources. A box labeled 'O-Cloud at Edge' contains a blue cloud labeled 'O-DU Resources'. Below the cloud, several lines connect to labels 'O-RU', 'O-RU', 'O-RU', '...', and 'O-RU'. A bracket on the right side of the cloud is labeled 'Pooling of Centralized Resources'. + +**Figure 13: Pooling of Centralized O-DU Resources** + +We note that being able to share/ O-DU resources somewhat dynamically is expected to be a solvable problem, although we understand that it is by no means a trivial problem. There are management considerations, among others. There may be incremental steps toward true shared pooling, where rehoming of O-RUs to different O-DUs can be performed more dynamically, based on traffic conditions. + +It is noted that O-DU centralization benefits the densest networks where several cell sites are within the O-RU to O-DU latency limits. Sparsely populated areas most probably will be addressed by vO-CU centralization only. + +Figure 14 shows the results of an analysis of a simulated greenfield deployment as an attempt to visualize the relative merit of simple centralization of O-DU ("oDU") vs. pooled centralization of O-DU ("poDU") vs. legacy DU ("BBU"), plotted against the realizable Cell Site pool size. + +![Figure 14: Comparison of Merit of Centralization Options vs. Number of Cell Sites in a Pool. The graph plots Watts/MHz (Normalized) on the Y-axis (log scale from 0.25 to 8) against Cell Sites on the X-axis (log scale from 1 to 64). Three lines are shown: oDU (yellow), BBU (red), and poDU (green). The BBU line is horizontal at 1.0. The oDU line starts at approximately 7.5 at 1 cell site and decreases to about 0.7 at 64 cell sites. The poDU line starts at approximately 7.5 at 1 cell site and decreases more steeply to about 0.3 at 64 cell sites.](7b5cf586beef7e75525810d1929fcf9b_img.jpg) + +| Cell Sites | oDU (Watts/MHz) | BBU (Watts/MHz) | poDU (Watts/MHz) | +|------------|-----------------|-----------------|------------------| +| 1 | 7.5 | 1.0 | 7.5 | +| 2 | 4.0 | 1.0 | 4.0 | +| 4 | 2.2 | 1.0 | 2.2 | +| 8 | 1.2 | 1.0 | 1.2 | +| 16 | 0.8 | 1.0 | 0.6 | +| 32 | 0.6 | 1.0 | 0.4 | +| 64 | 0.7 | 1.0 | 0.3 | + +Figure 14: Comparison of Merit of Centralization Options vs. Number of Cell Sites in a Pool. The graph plots Watts/MHz (Normalized) on the Y-axis (log scale from 0.25 to 8) against Cell Sites on the X-axis (log scale from 1 to 64). Three lines are shown: oDU (yellow), BBU (red), and poDU (green). The BBU line is horizontal at 1.0. The oDU line starts at approximately 7.5 at 1 cell site and decreases to about 0.7 at 64 cell sites. The poDU line starts at approximately 7.5 at 1 cell site and decreases more steeply to about 0.3 at 64 cell sites. + +**Figure 14: Comparison of Merit of Centralization Options vs. Number of Cell Sites in a Pool** + +An often-used measure is related to the power required to support a given number of carrier MHz. The lower the power used per carrier, the more efficient is the implementation. In Figure 14, the values of each curve are normalized to the metric of Watts/MHz for distributed legacy BBUs, normalized to equal 1. Please note that in this diagram, a lower value is better. The following assumptions apply to the figure: + +- A legacy BBU processes X MHz (for carriers) and consumes Y watts. For example, a specific BBU might process 1600 MHz and consume 160 watts. +- N legacy BBUs will process N x X MHz and consume N x Y watts and have a merit figure of 1, per normalization. If a given site requires less than X MHz, it will still be necessary to deploy an X MHz BBU. For example, we may need only 480 MHz but still deploy a 1600 MHz BBU. +- Simple Centralization (the “oDU” line): In this case, active TRPs are statically mapped to specific VMs and vO-DU tiles<sup>2</sup>. Fewer vO-DU tiles are required to support the same number of TRPs, because MHz per site is not a constant. + - Independent of resources to support active user traffic, a fixed power level is required to power Ethernet “frontplane” switches and hardware to support management and orchestration processes. + - In a pool, processing capacity will be added over time as required. + - Due to mobility traffic behavior, tiles will not be fully utilized, although centralization of resources will improve utilization when compared with a legacy BBU approach. +- Centralization with more dynamic pooling (the “poDU” line): In addition to active load balancing, individual traffic flows (which can last from a few hundreds of msecs to several seconds) will be routed to the least used tile, further optimizing (reducing) vO-DU tile requirements. +- As in the simple centralization approach above, there is a fixed power level required for hardware that supports switching, management and orchestration processes. + +As a final note, any form of centralization requires efficient transport between the O-RU and the O-DU resources. When O-RU functionality is distributed over a relatively large area (e.g., not concentrated in a single large building), the existence of a Fronthaul Gateway/Fronthaul Multiplexer is a key enabler. + +## 5.2 Performance Aspects + +Performance requirements drive architectural and design considerations. Performance can include attributes such as delay, packet loss, transmission loss, and delay variation (aka “jitter”). + +*Editor’s Note: While all aspects are of interest, delay has the largest impact on network design and will be the focus of this version. Future versions can address other performance aspects if desired and is FFS.* + +### 5.2.1 User Plane Delay + +This section discusses the framework for discussing delay of user-plane packets<sup>3</sup>, and also general delay numbers that it can be agreed that apply across all scenarios. Details relevant to a specific Scenario will be discussed in each Scenario’s subsection, as applicable. The purpose of these high-level targets is to act as a baseline for allocating the total latency budget to subsystems that are on the path of each constraint, as required for system engineering and dimensioning calculations, and to assess the impact on the function placement within the specific network site tiers. + +The goal is to establish reasonable maximum delay targets, as well as to identify and document the major infrastructure as well as O-RAN NF-specific delay contributing components. For each service or element, minimum delay should be considered to be zero. The implication of this is that any of the elements can be moved towards the Cell Site (e.g., in a fully distributed Cloud RAN configuration, all of O-CU-UP, O-DU and O-RU would be distributed to Cell Site). + +In real network deployments, the expectation is that, depending on the operator-specific implementation constraints such as location and fiber availability, deployment area density, etc., deployments result in anything between the fully distributed and maximally centralized configuration. Even on one operator’s network, it is common that there are many different sizes of Edge Cloud instances, and combinations of Centralized and Distributed architectures in same network are also common (e.g. network operator may choose to centralize the deployments on dense Metro areas to the extent possible and distribute the configurations on suburban/rural areas with larger cell sizes / cell density that do not translate to pooling benefits from more centralized architecture). However, the maximum centralization within the constraints of + +<sup>2</sup> A “vO-DU tile” refers to a chip or System on Chip (SoC) that provides hardware acceleration for math-intensive functionality such as that required for Digital Signal Processing. With the Option 7.2x split, acceleration of Forward Error Correction (FEC) functionality is required (FEC is optional for e.g. low band.), and other functionality could be considered for acceleration if desired. + +<sup>3</sup> Delay of control plane or OAM traffic is not considered in this section. + +latencies that can be tolerable is useful for establishing the basis for dimensioning of the maximum sizes, especially for the Edge and Regional Cloud PoPs. Figure 15 below illustrates the relationship among some key delay parameters. + +![Figure 15: Major User Plane Latency Components, by 5G Service Slice and Function Placement](92998b1ce11cc3176ade42df63ecdcde_img.jpg) + +The diagram illustrates the relationship between various network tiers (Central Cloud, Regional Cloud, Edge Cloud, Cell Site, and UE's) and the latency components for different 5G service slices (mMTC, eMBB, URLLC). It shows the placement of functions like UPF, O-CU-UP, O-DU, and O-RU across these tiers, along with transport delays (T<sub>C</sub>, T<sub>T3</sub>, T<sub>E3</sub>, T<sub>T2</sub>, T<sub>E2</sub>, T<sub>T1</sub>, T<sub>E1</sub>, T<sub>AIR</sub>) and RAN NF delays (T<sub>CU-UP</sub>, T<sub>DU</sub>, T<sub>RU</sub>, T<sub>UE</sub>). + +Figure 15: Major User Plane Latency Components, by 5G Service Slice and Function Placement + +**Figure 15: Major User Plane Latency Components, by 5G Service Slice and Function Placement** + +Please note the following: + +- NOTE 1: If the T2 and/or T3 transport network(s) is/are Packet Transport Network(s), then time allocation for the transport network elements processing and queuing delays will require some portion of maximum latency allocation and will require reduction of the maximum area accordingly. +- NOTE 2: Site Internal / fabric networks are not shown for clarity but need some latency allocation (effectively extensions or part of transport delays; per PoP tier designations T<sub>E1</sub>, T<sub>E2</sub>, T<sub>E3</sub> and T<sub>C</sub>). +- NOTE 3: To maximize the potential for resource pooling benefits, minimize network function redundancy cost, and minimize the amount of hardware / power in progressively more distributed sites (towards UEs), target design should attempt to maximize the distances and therefore latencies available for transport networks within the service- and RAN-specific time constraints, especially for T<sub>T1</sub>. +- NOTE 4: UPF, like EC/MEC, is outside of the scope of O-RAN, so UPF shown as a "black box" to illustrate where it needs to be placed in context of specific services to be able to take advantage of the RAN service-specific latency improvements. + +Figure 15 represents User Equipment locations on the right, and network tiers towards the left, with increasing latency and increasing maximum area covered per tier towards the left. These Mobile Network Operator's (MNO's) Edge tiers are nominated as Cell Site, Edge Cloud, and Regional Cloud, with one additional tier nominated as Central Cloud in the figure. + +The summary of the associated latency constraints as well as major latency contributing components as depicted in Figure 15 above is given in Table 1, below. + +**Table 1: Service Delay Constraints and Major Delay Contributors** + +| <b>RAN Service-Specific User Plane Delay Constraints</b> | | | | +|----------------------------------------------------------|--------------------------------------------------|--------------------------|--------------------------| +| <b>Identifier</b> | <b>Brief Description</b> | <b>Max. OWD<br/>(ms)</b> | <b>Max. RTT<br/>(ms)</b> | +| URLLC | Ultra-Reliable Low Latency Communications (3GPP) | 0.5 | 1 | +| URLLC | Ultra-Reliable Low Latency Communications (ITU) | 1 | 2 | +| eMBB | enhanced Mobile Broadband | 4 | 8 | +| mMTC | massive Machine Type Communications | 15 | 30 | +| <b>Transport Specific Delay Components</b> | | | | + +| | | | | +|---------------------------------------------------|----------------------------------------------------|-----|-----| +| $T_{AIR}$ | Transport propagation delay over air interface | | | +| $T_{E1}$ | Cell Site Switch/Router delay | | | +| $T_{T1}$ | Transport delay between Cell Site and Edge Cloud | 0.1 | 0.2 | +| $T_{E2}$ | Edge Cloud Site Fabric delay | | | +| $T_{T2}$ | Transport delay between Edge and Regional Cloud | 1 | 2 | +| $T_{E3}$ | Regional Cloud Site Fabric delay | | | +| $T_{T3}$ | Transport delay between Regional and Central Cloud | 10 | 20 | +| $T_C$ | Central Cloud Site Fabric delay | | | +| <b>Network Function Specific Delay Components</b> | | | | +| $T_{UE}$ | Delay Through the UE SW and HW stack | | | +| $T_{RU}$ | Delay Through the O-RU User Plane | | | +| $T_{DU}$ | Delay Through the O-DU User Plane | | | +| $T_{CU-UP}$ | Delay Through the O-CU User Plane | | | + +932 + +933 The transport network delays are specified as maximums, and link speeds are considered to be symmetric for all +934 components with exception of the air interface ( $T_{AIR}$ ). For the S-Plane services utilizing PTP protocol, it is a requirement +935 that the link lengths, link speeds and forward-reverse path routing for PTP are all symmetric. + +936 Radios (O-RUs) are always located in the Cell Site tier, while O-DU can be located “up to” Edge Cloud tier. It is possible +937 to move any of the user plane NF instances closer towards the cell site, as implicitly they would be inside the target +938 maximum delay, but it is not necessarily possible to move them further away from the Cell Sites while remaining within +939 the RAN internal and/or RAN service-specific timing constraints. A common expected deployment case is one where O- +940 DU instances are moved towards or even to the Cell Site and O-RUs (e.g. in Distributed Cloud-RAN configurations), or +941 in situations where the Edge Cloud needs to be located closer to the Cell Site due to fiber and/or location availability, or +942 other constraints. While this is expected to work well from the delay constraints perspective, the centralization and +943 pooling-related benefits will be potentially reduced or even eliminated in the context of such deployment scenarios. + +944 The maximum transport network latency between the site hosting O-DU(s) and sites hosting associated O-RU(s) is +945 primarily determined by the RAN internal processes time constraints (such as HARQ loop, scheduling, etc., time-sensitive +946 operations). For the purposes of this document, we use 100us latency, which is commonly used as a target maximum +947 latency for this transport segment in related industry specifications for user-plane, specifically “High100” on E-CPRI +948 transport requirements [4] section 4.1.1, as well as “Fronthaul” latency requirement in ITU technical report GSTR-TN5G +949 [6], section 7-2, and IEEE Std 802.1CM-2018 [5], section 6.3.3.1. Based on the 5us/km fiber propagation delay, this +950 implies that in a 2D Manhattan tessellation model, which is a common simple topology model for dense urban area fiber +951 routing, the maximum area that can be covered from a single Edge Cloud tier site hosting O-DUs is up to a 400km<sup>2</sup> area +952 of Cell Sites and associated RUs. Based on the radio inter-site distances, number of bands and other radio network +953 dimensioning specific parameters, this can be used to estimate the maximum number of Cell Sites and cell sectors that +954 can be covered from single Edge Cloud tier location, as well as maximum number of UEs in this coverage area. + +955 The maximum transport network latencies towards the entities located at higher tiers are constrained by the lower of F1 +956 interface latency (max 10 ms as per GSTR-TN5G [6], section 7.2), or alternatively service-specific latency constraints, +957 for the edge-located services that are positioned to take advantage of improved latencies. For eMBB, UE-CU latency +958 target is 4ms one-way delay, while for the URLLC it is 0.5ms as per 3GPP (or 1ms as per ITU requirements). The +959 placement of the O-CU-UP as well as associated UPF, to be able to provide URLLC services would have to be at most at +960 the Edge Cloud tier to satisfy the service latency constraint. For the eMBB services with 4ms OWD target, it is possible +961 to locate O-CU-UP and UPF on next higher latency location tier, i.e. Regional Cloud tier. Note that while not shown in +962 the picture, Edge compute / Multi-Access Edge Compute (MEC) services for a given RAN service type are expected to +963 be collocated with the associated UPF function to take advantage of the associated service latency reduction potential. + +964 For the services that do not have specific low-latency targets, the associated O-CU-UP and UPF can be located on higher +965 tier, similar to deployments in typical LTE network designs. This is designated as Central Cloud tier in the example in +966 Figure 15 above. For eMBB services, if there are no local service instances in the Edge or Regional clouds to take +967 advantage of the 4ms OWD enabled by eMBB service definition, but the associated services are provided from either +968 Central Clouds, transport networks or from other Edge Cloud / RAN instances (in case of user-to-user traffic), the +969 associated non-constrained (i.e. over 4ms from subscriber) eMBB O-CU-UP and UPF instances can be located in Central + +Cloud sites without perceivable impact to the service user, as in such cases the transport and/or service-specific latencies are dominant latency components. + +The intent of this section is not to micromanage the latency budget, but to rather establish a reasonable baseline for dimensioning purposes, particularly to provide basic assessment to enable sizing of the cloud tiers within the context of the service-specific constraints and transport allocations. As such, we get the following “allowances” for the aggregate unspecified elements: + +- URLLC<sub>3GPP</sub>: 0.5ms - 0.1ms ( $T_{T1}$ ) = 0.4ms $\geq T_{UE} + T_{AIR} + T_{E1} + T_{RU} + 2(T_{E2}) + T_{DU} + T_{CU-UP}$ +- URLLC<sub>ITU</sub>: 1ms - 0.1ms ( $T_{T1}$ ) = 0.9ms $\geq T_{UE} + T_{AIR} + T_{E1} + T_{RU} + 2(T_{E2}) + T_{DU} + T_{CU-UP}$ +- eMBB: 4ms - 0.1ms ( $T_{T1}$ ) - 1ms ( $T_{T2}$ ) = 2.9ms $\geq T_{UE} + T_{AIR} + T_{E1} + T_{RU} + 2(T_{E2}) + T_{DU} + T_{E3} + T_{CU-UP}$ +- mMTC<sub>15</sub>: 15ms - 0.1ms ( $T_{T1}$ ) - 1ms ( $T_{T2}$ ) - 10ms ( $T_{T3}$ ) = 3.9ms $\geq T_{UE} + T_{AIR} + T_{E1} + T_{RU} + 2(T_{E2}) + T_{DU} + T_{E3} + T_{CU-UP} + T_C$ + +If required, we may provide more specific allocations in later versions of the document, as we gain more implementation experience and associated test data, but at this stage it is considered to be premature to do so. It should also be noted that the URLLC specification is still work in progress at this stage in 3GPP, so likely first implementations will focus on eMBB service, which leaves 2.9ms for combined O-RAN NFs, air interface, UE and cloud fabric latencies. + +It is possible that network queuing delays may be the dominant delay contributor for some service classes. However, these delay components should be understood to be in context of the most latency-sensitive services, particularly on RU-DU interfaces, and relevant to the system level dimensioning. It is expected that if we will have multiple QoS classes, then the delay and loss parameters are specified on per-class basis, but such specification is outside of scope of this section. + +The delay components in this section are based on presently supported O-RAN splits, i.e., 3GPP reference split configurations 7-2 & 8 for the RU-DU split (as defined in O-RAN), and 3GPP split 2 for F1 (as defined in O-RAN) and associated transport allocations, and constraints are based on the 5G service requirements from ITU & 3GPP. + +Other extensions have been approved and included in version 2.0 of the O-RAN Fronthaul specification [7], which allow for so called “non-ideal” Fronthaul. It should be noted that while they allow substantially larger delays (e.g., 10 ms FH splits have been described and implemented outside of O-RAN), they cannot be considered for all possible 5G use cases, as for example it is clearly impossible to meet the 5G service-specification requirements over such large delay values over the FH for URLLC or even 4 ms eMBB services. In addition, in specific scenarios (e.g., high-speed users), adding latency to the fronthaul interface can result in reduced performance, and lower potential benefits, e.g. in Co-Ordinated Multi-Point (CoMP) mechanisms. + +## 5.3 Hardware Acceleration and Acceleration Abstraction Layer (AAL) + +As stated in Section 4.3.2, an O-Cloud Node is a collection of CPUs, Memory, Storage, NICs, BIOSes, BMCs, etc., and may include hardware accelerators to offload computational-intense functions with the aim of optimizing the performance of the O-RAN Cloudified NF (e.g., O-RU, O-DU, O-CU-CP, O-CU-UP, near-RT RIC). There are many different types of hardware accelerators, such as FPGA, ASIC, DSP, GPU, and many different types of acceleration functions, such as Low-Density Parity-Check (LDPC), Forward Error Correction (FEC), end-to-end high-PHY for O-DU, security algorithms for O-CU, and Artificial Intelligence for RIC. The combination of hardware accelerator and acceleration function, and indeed the option to use hardware acceleration, is the vendor’s choice; however, all types of hardware acceleration on the cloud platform should ensure the decoupling of software from hardware. This decoupling implies the following key objectives: + +- Multiple vendors of hardware GPP CPUs and accelerators (e.g., FGPA, ASIC, DSP, or GPU) can be used in O-Cloud platforms (including agreed-upon Acceleration Abstraction Layer as defined in an upcoming specification) from multiple vendors, which in turn can support the software providing RAN functionality. +- A given hardware and cloud platform shall support RAN software (including near-RT RIC, O-CU-CP, O-CU-UP, O-DU, and possibly O-RU functionality in the future) from multiple vendors. + +There are different concepts that should be considered for the hardware acceleration abstraction layer on the cloud platform; these are usually the following: + +- Accelerator Deployment Model +- Acceleration Abstraction Layer (AAL) Interface (i.e., the APIs used by the NFs) + +![Figure 16: Hardware Abstraction Considerations. The diagram shows two models of hardware abstraction. The left model, 'Abstracted (vhost_user)', shows a 'Cloud Platform' containing a 'backend' and an 'Accelerator'. The 'backend' is connected to an 'NF' (Network Function) which contains an 'API' and a 'Driver'. The 'Accelerator' is also connected to the 'Driver'. The right model, 'Pass Through', shows a 'Cloud Platform' containing an 'Accelerator' which is directly connected to an 'NF' containing an 'API' and a 'Driver'. Both models are labeled with a circled '1' and a circled '2'.](290512c08ab250f40a7703cb22936341_img.jpg) + +Figure 16: Hardware Abstraction Considerations. The diagram shows two models of hardware abstraction. The left model, 'Abstracted (vhost\_user)', shows a 'Cloud Platform' containing a 'backend' and an 'Accelerator'. The 'backend' is connected to an 'NF' (Network Function) which contains an 'API' and a 'Driver'. The 'Accelerator' is also connected to the 'Driver'. The right model, 'Pass Through', shows a 'Cloud Platform' containing an 'Accelerator' which is directly connected to an 'NF' containing an 'API' and a 'Driver'. Both models are labeled with a circled '1' and a circled '2'. + +Figure 16: Hardware Abstraction Considerations + +### 5.3.1 Accelerator Deployment Model + +Figure 16 above presents two common hardware accelerator deployment models as examples: an abstracted implementation utilizing a vhost\_user and virtIO type deployment, and a pass-through model using SR-IOV. While the abstracted model allows a full decoupling of the Network Function (NF) from the hardware accelerator, this model may not suit real-time latency sensitive NFs such as the O-DU. For better acceleration capabilities, SR-IOV pass through may be required, as it is supported in both VM and container environments. + +### 5.3.2 Acceleration Abstraction Layer (AAL) Interface + +To allow multiple NF vendors to utilize a given accelerator through its Acceleration Abstraction Layer (AAL) interface, the accelerators must provide an open-sourced API. Likewise, this API shall allow NFs applications to discover, configure, select and use (one or more) acceleration functions provided by a given accelerator on the cloud platform. Moreover, this API shall also support different offload architectures including look aside, inline and any combination of both. Examples of open APIs include DPDK's CryptoDev, EthDev, EventDev, and Base Band Device (BBDEV). + +When delivering an NF to an Operator, it is assumed that the supplier of that Network Function will provide not only the Network Function, but it will also package the appropriate Accelerator Driver (possibly provided by a 3<sup>rd</sup> party) and will indicate the corresponding AAL profile needed in the Operator's O-Cloud. Figure 17 illustrates this for both Container and Virtual Machine (VM) deployments. + +![Figure 17: Accelerator APIs/Libraries in Container and Virtual Machine Implementations. The diagram shows two implementations of an O-Cloud Site. The left implementation, 'O-RAN Network Functions in a Container', shows an 'O-Cloud Node' containing an 'NF Application' which is connected to 'APIs/Libraries' (e.g., AAL FEC profile) and an 'Acc. Driver'. The 'Acc. Driver' is connected to a 'Host OS' which contains an 'Acc. Driver'. The right implementation, 'O-RAN Network Functions in a Virtual Machine', shows an 'O-Cloud Node' containing a 'Virtual Machine' which contains an 'NF Application' connected to 'APIs/Libraries' (e.g., AAL FEC profile) and an 'Acc. Driver'. The 'Acc. Driver' is connected to a 'Guest OS' which contains an 'Acc. Driver'. Both implementations are connected to 'Deployment Management Services' and 'Infrastructure Management Services' (Acc. Mgmt.) within the 'O-Cloud Site'.](b87403b8c7182ada6d6b9c8ae467ff0a_img.jpg) + +Figure 17: Accelerator APIs/Libraries in Container and Virtual Machine Implementations. The diagram shows two implementations of an O-Cloud Site. The left implementation, 'O-RAN Network Functions in a Container', shows an 'O-Cloud Node' containing an 'NF Application' which is connected to 'APIs/Libraries' (e.g., AAL FEC profile) and an 'Acc. Driver'. The 'Acc. Driver' is connected to a 'Host OS' which contains an 'Acc. Driver'. The right implementation, 'O-RAN Network Functions in a Virtual Machine', shows an 'O-Cloud Node' containing a 'Virtual Machine' which contains an 'NF Application' connected to 'APIs/Libraries' (e.g., AAL FEC profile) and an 'Acc. Driver'. The 'Acc. Driver' is connected to a 'Guest OS' which contains an 'Acc. Driver'. Both implementations are connected to 'Deployment Management Services' and 'Infrastructure Management Services' (Acc. Mgmt.) within the 'O-Cloud Site'. + +Figure 17: Accelerator APIs/Libraries in Container and Virtual Machine Implementations + +### 5.3.3 Accelerator Management and Orchestration Considerations + +Note that Figure 17 shows the APIs/Libraries as used by the NF application running in a Container or a VM, but there are several entities that require management. Accordingly, the figure also shows the Accelerator Management and Accelerator Driver in the O-Cloud. As will be discussed in Section 5.6, these entities (in addition to any hardware accelerator considerations) will be managed via O2, specifically the Infrastructure Management Services. Figure 17 also shows that the Accelerator Driver (e.g., the PMD driver) needs to be supported both by the O-Cloud Platform, by the Guest OS in case of VMs, and by the NF packaged into a container. + +In general, the hardware accelerators shall be capable of being managed and orchestrated. In particular, hardware accelerators shall support feature discovery and life cycle management. Existing Open-Source solutions may be leveraged for both VMs and containers as defined in an upcoming O2 specification. Examples include OpenStack Nova and Cyborg, while in Kubernetes we can leverage the device plugin framework for vendors to advertise their device and associated resources for the accelerator management. + +## 5.4 Cloud Considerations + +In this section we talk about the list of cloud platform capabilities which is expected to be provided by the cloud platform to be able to support the deployment of the scenarios which are covered by this document. + +It is assumed that some or all deployment scenarios may be using VM orchestrated/managed by OpenStack and / or Container managed/orchestrated by Kubernetes, and therefore this section will cover both options. + +The discussion in most sub-sections of this section is structured into (up to) three parts: (1) Common, (2) Container only, and (3) VM only. + +### 5.4.1 Networking requirements + +A Cloud Platform should have the ability to support high performance N – S and E – W networking, with high throughput and low latency. + +#### 5.4.1.1 Support for Multiple Networking Interfaces + +**Common:** In the different scenarios, near-RT RIC, vO-CU, and vO-DU all depend on having support for multiple network interfaces. The Cloud Platform is required to support the ability to assign multiple networking interfaces to a single container or VM instance, so that the cloud platform could support successful deployment for the different scenarios. + +**Container-only:** For example, the cloud platform can achieve this by supporting the implementation of Multus Container Networking Interface (CNI) Plugin. For more details, please see <https://github.com/intel/multus-cni>. + +![Diagram illustrating the network interfaces attached to a Pod, as Provisioned by Multus CNI. The diagram shows a Pod with two network interfaces, net0 and net1, connected to 'other networks' (NW1 and NW2) via 'NetworkAttachments'. The Pod is also connected to 'Kubernetes servers (api-server, kubelet so on)' via a 'cluster network/master plugin' and an 'eth0' interface. The diagram includes a list of features: Specific User Traffic, (Liveness and Readiness) Probes, and Communication between API and Pod.](673c0b4d6f9f9b55b55bd0f71962c1ee_img.jpg) + +The diagram illustrates the network architecture for a Pod in a Kubernetes cluster. A central blue box represents the 'Pod', containing two network interfaces labeled 'net0' and 'net1'. To the left, two cloud shapes represent 'other networks', labeled 'NW1' and 'NW2'. A yellow callout box labeled 'NetworkAttachments' points to the connections between the Pod and these external networks. To the right, a yellow callout box labeled 'cluster network/master plugin' points to the connection between the Pod and the 'Kubernetes servers (api-server, kubelet so on)'. A specific interface 'eth0' is shown on the Pod connected to the cluster network. A blue Kubernetes logo is also present. Below the diagram, a bulleted list specifies the supported features: 'Specific User Traffic', '(Liveness and Readiness) Probes', and 'Communication between API and Pod'. + +Diagram illustrating the network interfaces attached to a Pod, as Provisioned by Multus CNI. The diagram shows a Pod with two network interfaces, net0 and net1, connected to 'other networks' (NW1 and NW2) via 'NetworkAttachments'. The Pod is also connected to 'Kubernetes servers (api-server, kubelet so on)' via a 'cluster network/master plugin' and an 'eth0' interface. The diagram includes a list of features: Specific User Traffic, (Liveness and Readiness) Probes, and Communication between API and Pod. + +**Figure 18: Illustration of the Network Interfaces Attached to a Pod, as Provisioned by Multus CNI** + +**VM-only:** OpenStack provides the Neutron component for networking. For more details, please see <https://docs.openstack.org/neutron/stein/> + +#### 5.4.1.2 Support for High Performance N-S Data Plane + +**Common:** The Fronthaul connection between the O-RU/RU and vO-DU requires high performance and low latency. This means handling packets at high speed and low latency. As per the different scenarios covered in this document, + +multiple vO-DUs may be running on the same physical cloud platform, which will result in the need for sharing the same physical networking interface with multiple functions. Typically, the SR-IOV networking interface is used for this. + +The cloud platform will need to provide support for assigning SR-IOV networking interfaces to a container or VM instance, so the instance can use the network interface (physical function or virtual function) directly without using a virtual switch. + +If only one container needs to use the networking interface, the PCI pass-through network interface can provide high performance and low latency without using a virtual switch. + +In general, the following two items are needed for high performance N-S data throughput: + +- Support for SR-IOV, i.e., the ability to assign SR-IOV NIC interfaces to the containers/ VMs +- Support for PCI pass-through for direct access to the NIC by the container/ VM + +**Container-only:** When containers are used, the cloud platform can achieve this by supporting the implementation of SR-IOV Network device plugin for Kubernetes. For more details, please refer to <https://github.com/intel/sriov-network-device-plugin> + +**VM-only:** OpenStack provides the Neutron component for networking. For more details, please see <https://docs.openstack.org/neutron/stein/admin/config-sriov.html>. + +#### 5.4.1.3 Support for High-Performance E-W Data Plane + +**Common:** High-performance E-W data plane throughput is a requirement for the implementation of the different near-RT RIC, vO-CU, and vO-DU scenarios which are covered in this document. + +One of commonly used options for E-W high-performance data plane is the use of a virtual switch which provides basic communication capability for instances deployed at either the same machine or different machines. It provides L2 and L3 network functions. + +To get the high performance required, one of the options is to use a Data Plane Development Kit (DPDK)-based virtual switch. Using this method, the packets will not go into Linux kernel space networking, and instead will implement userspace networking which will improve the throughput and latency. To support this, the container or VM instance will need to use DPDK to accelerate packet handling. + +The cloud platform will need to provide the mechanism to support the implementation of userspace networking for container(s) / VM(s). + +**Container-only:** As an example, the cloud platform can achieve this by supporting implementation of Userspace CNI Plugin. For more details, please refer to <https://github.com/intel/userspace-cni-network-plugin>. + +![Diagram illustrating the Userspace CNI Plugin architecture. The diagram shows a stack of components: at the top is a 'Kubernetes Pod' containing a 'Container' which runs a 'VNF Application'. The VNF Application connects to 'DPDK', which in turn connects to 'virtio_user'. Below 'virtio_user' is 'vhostuser', which connects to 'OVS- DPDK / VPP'. This switch connects to the 'eth0' interface, which finally connects to the 'NIC' (Network Interface Card) at the bottom. Logos for 'Open vSwitch' and 'io' are also visible on the left side of the diagram.](52e9b22241c70801c875a329c2dbc785_img.jpg) + +Diagram illustrating the Userspace CNI Plugin architecture. The diagram shows a stack of components: at the top is a 'Kubernetes Pod' containing a 'Container' which runs a 'VNF Application'. The VNF Application connects to 'DPDK', which in turn connects to 'virtio\_user'. Below 'virtio\_user' is 'vhostuser', which connects to 'OVS- DPDK / VPP'. This switch connects to the 'eth0' interface, which finally connects to the 'NIC' (Network Interface Card) at the bottom. Logos for 'Open vSwitch' and 'io' are also visible on the left side of the diagram. + +**Figure 19: Illustration of the Userspace CNI Plugin** + +**VM-only:** OVS DPDK is an example of a Host userspace virtual switch and could provide high performance L2/L3 packet receive and transmit. + +###### 1110 5.4.1.4 Support for Service Function Chaining + +1111 **Common:** Support for a Service Function Chaining (SFC) capability requires the ability to create a service function +1112 chain between multiple VMs or containers. In the virtualization environment, multiple instances will usually be deployed, +1113 and being able to efficiently connect the instances to provide service will be a fundamental requirement. + +1114 The ability to dynamically configure traffic flow will provide flexibility to Operators. When the service requirement or +1115 flow direction needs to be changed, the Service Function Chaining capability can be used to easily implement it instead +1116 of having to restart and reconfigure the services, networking configuration and Containers/VMs. + +1117 **Container-only:** An example of SFC functionality is found at: <https://networkservicemesh.io/> + +1118 **VM only:** The OpenStack Neutron SFC and OpenFlow-based SFC are examples of solutions that can implement the +1119 Service Function Chaining capability. + +###### 1120 5.4.1.5 Support for VLAN based networking + +1121 **Common:** VLAN based networking is the most common and fundamental form of networking. VLANs are typically +1122 used to provide the isolation of various types of traffic in cloud environments. Cloud platforms must support the traffic +1123 isolation requirements of the application. + +1124 The O-RAN slicing use cases specified in [14] require the use of VLANs by O-RAN NFs to distinguish traffic belonging +1125 to different slices. To support this requirement, the O-Cloud platform must provide support for trunked VLAN network +1126 interfaces to be made available to Cloudified NFs (VMs and Containers) so that packets tagged with different VLANs +1127 can be transported on the same virtual network interface. + +1128 +1129 VLANs may also be used to differentiate slices in the transport network once the appropriate VLAN tags are applied by +1130 Cloudified NFs in the Data Center as specified in [14]. Therefore, the O-Cloud must also ensure that any VLAN tags +1131 applied by the O-RAN NFs are carried over to the transport network. + +1133 **Container-only:** For example, the cloud platform can achieve this by supporting the implementation of Multus Container +1134 Networking Interface (CNI) Plugin. For more details, please see <https://github.com/k8snetworkplumbingwg/multus-cni> + +1135 **VM only:** OpenStack provides the Neutron component for networking. For more details, please see +1136 <https://docs.openstack.org/neutron/stein/> + +1137 + +###### 1138 5.4.1.6 Support for O-Cloud Gateways to connect O-Cloud Sites with Transport Networks + +1139 In disaggregated O-RAN deployments, the Network Functions (NFs) may be deployed in multiple O-Clouds or different +1140 locations within a given distributed O-Cloud. As an example, O-DU and O-CU-CP may be deployed in two different O- +1141 Clouds or different distributed O-Cloud sites. For O-CU-CP to communicate with O-DU, the networking needs to span +1142 across the O-Clouds or distributed O-Cloud sites via external transport networks. + +1143 For a transport network to interconnect different O-Cloud Site Networks, it needs an endpoint, herein referred to as an +1144 O-Cloud Attachment Circuit (OCAC), in each of the O-Cloud Sites. For the sake of this architecture, an OCAC is a +1145 logical connection enabling connectivity of O-Cloud Site Networks deployed within the O-Cloud Site to the outside of +1146 the O-Cloud Site. An O-Cloud Bearer is a physical or logical link that establishes connectivity between the O-Cloud Site +1147 and transport networks. It's possible to carry one or more OCAC over the same O-Cloud Bearer. An O-Cloud Gateway +1148 can encapsulate, bridge, or stitch the O-Cloud Site Networks in different O-Cloud Sites e.g., for distributed O-Cloud +1149 Node Cluster Networks. In the deployment scenario where an O-Cloud Site includes the gateway functionality, one or +1150 more OCACs can exist on the O-Cloud Gateway. + +1151 +1152 Beside the interconnection of O-Clouds and distributed O-Cloud sites, there are other external connections that also need +1153 to terminate the O-Clouds and O-Cloud sites domains in an O-Cloud Gateway function to ensure a clear demarcation of +1154 the different network domains. It is FFS which other gateway functions are needed as how they are to be named and how +1155 they are to be managed for example seeking inspiration in the ETSI GS NVF-SOL.005. + +1157 O-Cloud shall provide support for one or more O-Cloud Gateway instances to provide connectivity to one or more +1158 transport networks. This does not restrict or impose any networking models within the O-Cloud as long as the O-Cloud + +provides a mechanism to connect the NFs to the O-Cloud Gateway so that the deployed NFs could reach other NFs deployed in other O-Clouds or O-Cloud sites, while maintaining the segmentation of the traffic between the NFs. It shall also be noted that each network domain can have its own networking model and segmentation scheme. + +O-Cloud Gateway augments the O-Cloud architecture model depicted by figure 10 and 11 in section 4.3.2. + +### 5.4.2 Assignment of Acceleration Resources + +**Common:** For both container and VM solutions, specific devices such as accelerator (e.g., FPGA, GPU) may be needed. In this case, the cloud platform needs to be able to assign the specified device to container instance or VM instance. + +For example, some L1 protocols require an FFT algorithm (to compute the DFT) that could be implemented in an FPGA or GPU, and the vO-DU would need the PCI Pass-Through to assign the accelerator device to the vO-DU for access and use. + +### 5.4.3 Real-time / General Performance Feature Requirements + +#### 5.4.3.1 Host Linux OS + +##### 5.4.3.1.1 Support for Pre-emptive Scheduling + +Support may be required to support Pre-emptive Scheduling (real time Linux uses the preempt\_rt patch). Generally, without real time features, it is very difficult for an application to get deterministic response times for events, interrupts and other reasons<sup>4</sup>. In addition, during the housekeeping processes in Linux system, the application also cannot guarantee the running time (CPU cycle), so from the wireless application design perspective, it needs the real time feature. In addition, to support the requirements of high throughput, multiple accesses and low latency, some wireless applications need the priority-based OS environment. + +#### 5.4.3.2 Support for Node Feature Discovery + +**Common:** Automated and dynamic placement of Cloud-Native Network Functions (CNFs) / microservices and VMs is needed, based on the hardware requirements imposed on the vO-DU, vO-CU and near-RT RIC functions. This requires the cloud platform to support the ability to discover the hardware capabilities on each node and advertise it via labels vs. nodes, and allows O-RAN Cloudified NFs' descriptions to have hardware requirements via labels. This mechanism is also known as Node Feature Discovery (NFD). + +**Container-only:** For example, the cloud platform can achieve this by supporting implementation of NFD for Kubernetes. For more details, please see <https://github.com/kubernetes-sigs/node-feature-discovery>. + +**VM-only:** VMs can use OpenStack mechanisms. For example, the OpenStack Nova filter, host aggregates and availability zones can be used to implement the same function. + +#### 5.4.3.3 Support for CPU Affinity and Isolation + +**Common:** The vO-DU, vO-CU and even the near-RT RIC are performance sensitive and require the ability to consume a large amount of CPU cycles to work correctly. They depend on the ability of the cloud platform to provide a mechanism to guarantee performance determinism even when there are noisy neighbors. + +**Container-only:** This requires the cloud platform to support using affinity and isolation of cores, so high performance Kubernetes Pod cores also can be dedicated to specified tasks. For example, the cloud platform can achieve this by implementing CPU Manager for Kubernetes. For more details, please refer to <https://github.com/intel/CPU-Manager-for-Kubernetes>. + +**VM-only:** For example the modern Linux operating system uses the Symmetric MultiProcessing (SMP) mode, so the system process and application will be located at different CPU cores. To run the VM and guarantee the VM performance, the capability to assign the specific CPU cores to a VM is the way to do that. And at the same time, CPU isolation will reduce the inter-core affinity. Please refer to <https://docs.openstack.org/senlin/pike/scenarios/affinity.html> + +<sup>4</sup> Other options include things such as Linux signal, softwareirq, and perhaps using a common process. Because the pre-emptive kernel could interrupt the low priority process and occupy the CPU, it will get more chance to run the high priority process. Then through proper application design, it will have guaranteed time/resource and can have deterministic performance. + +#### 5.4.3.4 Support for Dynamic HugePages Allocation + +**Common:** When an application requires high performance and performance determinism, the reduction of paging is very helpful. vO-DU, vO-CU and even near-RT RIC can require performance determinism. The cloud platform needs to be able to support the ability to provide this mechanism to applications that require it. + +This requires the cloud platform to support ability to dynamically allocate the necessary amount of the faster memory (a.k.a. HugePages) to the container or VM as necessary, and also to relinquish this memory allocation in the event of unexpected termination. + +**Container-only:** For example, the cloud platform can achieve this by supporting implementation of Manage HugePages in Kubernetes. For more details please refer to <https://kubernetes.io/docs/tasks/manage-hugepages/scheduling-hugepages/>. + +**VM-only:** For example, the OpenStack Nova flavor setting can be used to configure the HugePage size for a VM instance. See <https://docs.openstack.org/nova/pike/admin/huge-pages.html> + +#### 5.4.3.5 Support for Topology Manager + +**Common:** Some of the cloud infrastructure which is targeted in the scenarios in this document may have servers which utilize a multiple-socket configuration which comes with multiple memory regions. Each core<sup>5</sup> is connected to a memory region. While each CPU on one socket can access the memory region of the CPUs on another socket of the same board, the access time is significantly slower when crossing socket boundaries, and this will affect performance significantly. + +The configuration of hardware with multiple memory regions is also known as Non-Uniform Memory Access (NUMA) regions. To support automated and dynamic placement of CNFs/microservices or VMs based on cloud infrastructure that has multiple NUMA regions and guarantee the response time of the application (especially for vO-DU), it is critical to be able to ensure that all the containers/VMs are associated with core(s) which are connected to the same NUMA region. In addition, if the application relies on access to hardware accelerators and/or I/O which uses memory as a way to interact with the application, it is also critical that those also use the same NUMA region that the application uses. + +The cloud platform will need to provide the mechanism to enable managing the NUMA topology to ensure the placement of specified containers/VMs on cores which are on the same NUMA region, as well as making sure that the devices which the application uses are also connected to the same NUMA region. + +![Diagram illustrating two NUMA regions (NUMA 1 and NUMA 2) connected via an Interconnect Path. Each NUMA region contains a Socket with multiple Cores (Core 1 to Core N). Memory (Mem) is connected to each Socket. The Sockets are connected to each other via the Interconnect Path. PCIe connections are shown between the Sockets and the Interconnect Path.](cac2388d8ab649cec9ffe10c6b295303_img.jpg) + +The diagram shows two NUMA nodes, NUMA 1 and NUMA 2, enclosed in a light blue rounded rectangle. Each NUMA node contains a 'Socket' box. Inside each socket box, there are 'Core 1' and 'Core N' with an ellipsis between them. To the left of each socket is a stack of green rectangles labeled 'Mem', with blue double-headed arrows connecting them to the socket. To the right of each socket is another stack of green rectangles labeled 'Mem', also with blue double-headed arrows. Between the two socket boxes is a vertical 'Interconnect Path' with yellow double-headed arrows connecting to each socket. Below each socket box, there are three vertical black arrows pointing up and down, labeled 'PCIe', which connect to the Interconnect Path. The entire diagram is labeled 'NUMA 1' and 'NUMA 2' at the bottom of each respective section. + +Diagram illustrating two NUMA regions (NUMA 1 and NUMA 2) connected via an Interconnect Path. Each NUMA region contains a Socket with multiple Cores (Core 1 to Core N). Memory (Mem) is connected to each Socket. The Sockets are connected to each other via the Interconnect Path. PCIe connections are shown between the Sockets and the Interconnect Path. + +Figure 20: Example Illustration of Two NUMA Regions + +#### 5.4.3.6 Support for Scale In/Out + +**Common:** The act of scaling in/out of containers/ VMs can be based on triggers such as CPU load, network load, and storage consumption. The network service usually is not just a single container or VM, and in order to leverage the container/ VM benefit, the network service usually will have multiple containers/ VMs. But if demand is changing + +<sup>5</sup> In this document, we use the terms core and socket in the following way. A socket, or more precisely the multichip platform that fits into a server socket, contains multiple cores, each of which is a separate CPU. Each core in a socket has some dedicated memory, and also some shared memory among other cores of the same socket, which are within the same NUMA zone. + +1233 dynamically, especially for the O-CU, the service needs to be scaled in/out according to service requirements such as +1234 subscriber quantity. + +1235 For example, when the number of subscribers increases, the system needs to start more container/ VM instances to ensure +1236 the service quality. From the cloud platform perspective, it could monitor the CPU load; if the load reaches a level such +1237 as 80%, it needs to scale out. If the CPU load drops 40%, it could then scale in. + +1238 Different services can scale in/out depending on different criteria, such as the CPU load, network load and storage +1239 consumption. Support for scale in/out can be helpful in implementing on-demand services. + +1240 *Editor's Note: Support for scale up/down is not discussed at this time but may be revisited in the* +1241 *future.* + +###### 1242 5.4.3.7 Support for Device Plugin + +1243 **Common:** For vO-DU, vO-CU and near-RT RIC applications, hardware accelerators such as SmartNICs, FPGAs and +1244 GPUs may be required to meet performance objectives that can't be met by using software only implementations. In +1245 other cases, such accelerators can be useful as an option to reduce the consumption of CPU cycles to achieve better cost +1246 efficiency. + +1247 The cloud platform will need to provide the mechanism to support those accelerators. This in turn requires support the +1248 ability to discover, advertise, schedule and manage devices such as SR-IOV, GPU, and FPGA. + +1249 **Container-only:** For example, the cloud platform can achieve this by supporting implementation of Device Plugins in +1250 Kubernetes. For more details please check: [https://kubernetes.io/docs/concepts/extend-kubernetes/compute-storage-](https://kubernetes.io/docs/concepts/extend-kubernetes/compute-storage-net/device-plugins/) +1251 [net/device-plugins/](https://kubernetes.io/docs/concepts/extend-kubernetes/compute-storage-net/device-plugins/). + +1252 **VM-only:** The PCI passthrough feature in OpenStack allows full access and direct control of a physical PCI device in +1253 guests. This mechanism is generic for any kind of PCI device, and runs with a Network Interface Card (NIC), Graphics +1254 Processing Unit (GPU), or any other devices that can be attached to a PCI bus. Correct driver installation is the only +1255 requirement for the guest to properly use the devices. + +1256 Some PCI devices provide Single Root I/O Virtualization and Sharing (SR-IOV) capabilities. When SR-IOV is used, a +1257 physical device is virtualized and appears as multiple PCI devices. Virtual PCI devices are assigned to the same or +1258 different guests. In the case of PCI passthrough, the full physical device is assigned to only one guest and cannot be shared. + +1259 See <https://wiki.openstack.org/wiki/Cyborg> + +###### 1260 5.4.3.8 Support for Direct IRQ Assignment + +1261 **VM-only:** The general-purpose platform has many devices that will generate the IRQ to the system. To develop a +1262 performance-sensitive application, inclusion of low-latency and deterministic timing features, and assigning the IRQ to a +1263 specific CPU core, will reduce the impact of housekeeping processes and decrease the response time to desired IRQs. + +###### 1264 5.4.3.9 Support for No Over Commit CPU + +1265 **VM-only:** The “No Over Commit CPU” VM creation option is able to guarantee VM performance with a “dedicated +1266 CPU” model. + +1267 In traditional telecom equipment design, this will maintain the level of CPU utilization to avoid burst and congestion +1268 situations. In a virtualization environment, performance-sensitive applications such as vO-DU, vO-CU, and near-RT RIC +1269 will need the platform to provide a mechanism to secure the CPU resource. + +###### 1270 5.4.3.10 Support for Specifying CPU Model + +1271 **VM-only:** OpenStack can use the CPU model setting to configure the vCPU for a VM. For example, QEMU allows the +1272 CPU options to be “Nehalem”, “Westmere”, “SandyBridge” or “IvyBridge”, or alternatively it could be configured as +1273 “host-passthrough”. This allows VMs to leverage advanced features of selected CPU architectures. For the vO-CU and +1274 vO-DU design and implementation, there will be some algorithm and computing functions that can leverage host CPU +1275 instructions to realize some benefits such as performance. The cloud platform needs to provide this capability to VMs. + +### 5.4.4 Storage Requirements + +The storage requirements are the same for both VM and Container based implementations. + +For O-RAN components, the O-RAN Cloudified NF needs storage for the image and for the O-RAN Cloudified NF itself. It should support different scale, e.g., for a Regional Cloud vs. an Edge Cloud. The cloud platform needs to support a large-scale storage solution with redundancy, medium and small-scale storage solutions for two or more servers, and a very small-scale solution for a single server. + +### 5.4.5 Notification Subscription Framework + +Applications should have the ability to retrieve notifications that are necessary for their functionality. For example, vO-DU needs to know that the node that it starts on has a PTP clock in sync with the master clock. + +Rationale – Application functionality often relies on but is not limited to O-Cloud platform HW resources such as FPGA, GPU, PHC. Hence, these application(s) should have the ability to select the resources that will provide them notifications about the status of these resources, initial state and changing state. This requires the applications to use a privilege mode in order to access the O-Cloud platform drivers and retrieve the status. However, in a Cloud Native environment, applications should not have a privilege mode for accessing the O-Cloud resources. This framework allows applications to subscribe for their necessary notifications without claiming a privilege mode and comply with O-Cloud Native requirements. + +#### 5.4.5.1 O-Cloud Notification Subscription Requirements + +##### Tracking function: + +- tracks for resource(s) state of relevant data (for example, change in class of a master clock) +- tracking function can be configured with tracking frequency per the resource being tracked (default value will be defined) + +##### Registration function: + +- allows application(s) and/or SMO (or other entities) to query for the resources that provide notifications +- allows application(s) and/or SMO (or other entities) to subscribe to receiving notifications from the selected resource(s) +- allows application(s) and/or SMO (or other entities) to subscribe to pulling notifications/data from the selected resource(s) +- allows application(s) and/or SMO (or other entities) to unsubscribe to notification(s) which were previously subscribed to for either receiving or pulling notifications +- The registration function updates the notification function about the state of the subscription and its request type (receiving or pulling notifications) + +##### Notification function: + +- used by the tracking function to message registered listeners of the resource state and/or its relevant data +- pulls the tracking function per the application and/or SMO request +- as soon as an application and/or SMO registers it receives a notification of the resource(s) status it is subscribed to + +Figure 21 illustrates the architecture for implementing a framework for notification subscription. This diagram shows the functionally and interaction **from a logical perspective**, however, where these functions reside or how they are implemented is not in scope of this document and will be described by Cloud Platform Reference Design [12]. + +![Figure 21: O-Cloud Notification Framework Architecture. The diagram shows the interaction and functionality from a logical perspective. It includes 'Other entities (e.g. SMO)' outside the 'O-Cloud' boundary. Inside 'O-Cloud', there is an 'Application (e.g. O-vDU)' and a 'Notification Framework' containing 'registration function', 'notification function', and 'tracking function'. 'Resources' are shown at the bottom. Interactions include 'Queries / Subscribes' from SMO to Application and registration function, 'Notifications Push/Pull' from registration function to SMO and Application, 'Reg Update' from registration function to notification function, 'Change in State or Pull' from notification function to tracking function, and 'Tracks resource(s)' from tracking function to Resources.](5a6aa3d4c32c769ddb4ee66caad69b08_img.jpg) + +``` + +graph TD + SMO[Other entities +(e.g. SMO)] + subgraph OCloud [O-Cloud] + Application[Application +(e.g. O-vDU)] + subgraph NotificationFramework [Notification Framework] + registration[registration function] + notification[notification function] + tracking[tracking function] + end + Resources[Resources] + end + + SMO -- "Queries / Subscribes" --> Application + SMO -- "Queries / Subscribes" --> registration + registration -- "Notifications Push/Pull" --> SMO + registration -- "Notifications Push/Pull" --> Application + registration -- "Reg Update" --> notification + notification -- "Change in State or Pull" --> tracking + tracking -- "Tracks resource(s)" --> Resources + +``` + +Figure 21: O-Cloud Notification Framework Architecture. The diagram shows the interaction and functionality from a logical perspective. It includes 'Other entities (e.g. SMO)' outside the 'O-Cloud' boundary. Inside 'O-Cloud', there is an 'Application (e.g. O-vDU)' and a 'Notification Framework' containing 'registration function', 'notification function', and 'tracking function'. 'Resources' are shown at the bottom. Interactions include 'Queries / Subscribes' from SMO to Application and registration function, 'Notifications Push/Pull' from registration function to SMO and Application, 'Reg Update' from registration function to notification function, 'Change in State or Pull' from notification function to tracking function, and 'Tracks resource(s)' from tracking function to Resources. + +Note: The diagram shows the interaction and functionality from a logical perspective only but not where these functions reside or how they are implemented + +**Figure 21: O-Cloud Notification Framework Architecture** + +## 5.5 Sync Architecture + +Synchronization mechanisms and options are receiving significant attention in the industry. + +*Editor's Note: O-RAN Working Groups 4 and 5 are addressing some aspects of synchronization, and more discussion of Sync is expected in future versions of this document.* + +Version 2 of the Control, User and Synchronization (CUS) Plane Specification [7] discusses, in chapter 9.2.2, "Clock Model and Synchronization Topology", four topology configuration options Lower Layer Split Control Plane 1 – 4 (LLS-C1 – LLS-C4) that are required to support different O-RAN deployment scenarios. Configuration LLS-C3 is seen as the most likely initial option for deployment and is discussed below. This section will provide a summary of what is required to support the LLS-C1 and LLS-C3 synchronization topology from the cloud platform perspective. + +Note that in chapter 6 "Deployment Scenarios and Implementation Considerations" of this document, we call the site which runs the vO-DU the "Edge Cloud", while the Control, User and Synchronization (CUS) Plane Specification [7] calls it the "Central Site". However, the meaning is the same. + +### 5.5.1 Cloud Platform Time Synchronization Architecture + +The Time Sync deployment architecture which is described below relies on usage of Precision Time Protocol (PTP) IEEE 1588-2008 (a.k.a. IEEE 1588 Version 2) to synchronize clocks throughout the Edge Cloud site. + +For LLS-C3 in the CUS specification [7], vO-DU may act as a Telecom Slave Clock (T-TSC) and select the time source the same SyncE and PTP distribution from fronthaul as O-RU. Please note that the following synchronization topology for LLS-C3 will address only the case where O-DU and O-RU are synchronized from the same time source connected to the fronthaul network, other cases are for Further Study. + +For LLS-C1, the O-Cloud running the vO-DU acts as synchronization master towards the fronthaul interface to synchronize the O-RU. Please note that the following synchronization topology for LLS-C1 will address only the case where O-DU synchronization source is from a local PRTC (GNSS receiver), other cases are for Further Study. + +#### 5.5.1.1 Edge Cloud Site Level – LLS-C3 Synchronization Topology + +This section outlines what the time synchronization architecture should be from the cloud platform perspective and identifies requirements that the Cloud Platform and Edge Site need to support in order to support the O-RAN deployment scenarios that use the LLS-C3 synchronization topology described in CUS specification [7]. + +##### 5.5.1.1.1 LLS-C3 Synchronization Topology Edge Site Time Synchronization Architecture + +The deployment architecture at the Edge Cloud site level includes: + +- Primary Reference Time Clock (PRTC)-traceable time source (i.e., Grandmaster Clocks): + - External precision time source for the PTP networks, usually based on Global Navigation Satellite System/Global Positioning System (GNSS/GPS) +- Compute Nodes: + - Compute Nodes synchronize their clocks to a Grandmaster Clock via the Fronthaul Network +- Controller Nodes: + - Controller Nodes synchronize their clocks to the Network Time Protocol (NTP) via the Management Network + +Figure 22 illustrates the relationship of these entities where the Controller functions are hosted on separate nodes from the Compute nodes. Figure 23 illustrates the relationships where each Compute node also includes the Controller functions (i.e., the hyperconverged case). + +![Figure 22: Edge Cloud Site Time Sync Architecture for LLS-C3. The diagram shows a three-tier architecture. The top tier is the Management Network, containing O-Cloud Management (OCM) and Controller Nodes (controller-0 to controller-N). The middle tier is the Management Network, containing O-Cloud Compute Nodes (compute-0 to compute-N). The bottom tier is the Data Network, containing the Fronthaul Network and Cell Sites (O-RU). A Grandmaster Clock(s) is connected to the Fronthaul Network via a T-BC PTP Switch. The Grandmaster Clock(s) is labeled 'M' (Master) and the Cell Sites are labeled 'S' (Slave). The Controller Nodes are connected to the O-Cloud Compute Nodes via NTP. The O-Cloud Compute Nodes are connected to the Cell Sites via the Fronthaul Network. The Cell Sites are connected to the T-BC PTP Switch via the Fronthaul Network. The T-BC PTP Switch is connected to the Grandmaster Clock(s) via PTP.](d9d43f33b3d1ba3130af40af697bc766_img.jpg) + +Figure 22: Edge Cloud Site Time Sync Architecture for LLS-C3. The diagram shows a three-tier architecture. The top tier is the Management Network, containing O-Cloud Management (OCM) and Controller Nodes (controller-0 to controller-N). The middle tier is the Management Network, containing O-Cloud Compute Nodes (compute-0 to compute-N). The bottom tier is the Data Network, containing the Fronthaul Network and Cell Sites (O-RU). A Grandmaster Clock(s) is connected to the Fronthaul Network via a T-BC PTP Switch. The Grandmaster Clock(s) is labeled 'M' (Master) and the Cell Sites are labeled 'S' (Slave). The Controller Nodes are connected to the O-Cloud Compute Nodes via NTP. The O-Cloud Compute Nodes are connected to the Cell Sites via the Fronthaul Network. The Cell Sites are connected to the T-BC PTP Switch via the Fronthaul Network. The T-BC PTP Switch is connected to the Grandmaster Clock(s) via PTP. + +Figure 22: Edge Cloud Site Time Sync Architecture for LLS-C3 + +![Figure 23: Hyperconverged Edge Cloud Time Sync Architecture for LLS-C3. The diagram shows a Management Network at the top connected to a Data Network below. The Management Network contains an O-Cloud Hyperconverged block with Controller-0 and Controller-1, each with a corresponding compute node (compute-0, compute-1). These are connected to a Grandmaster Clock(s) block containing a Clock Source. The Data Network contains a Fronthaul Network block with PTP and T-BC/PTP Switch components. The Fronthaul Network is connected to multiple Cell Site (O-RU) blocks, each labeled with an 'S' for Slave. A legend indicates 'M' for Master and 'S' for Slave.](4ca75796e11673fd1833bdf9d6b14bdf_img.jpg) + +Figure 23: Hyperconverged Edge Cloud Time Sync Architecture for LLS-C3. The diagram shows a Management Network at the top connected to a Data Network below. The Management Network contains an O-Cloud Hyperconverged block with Controller-0 and Controller-1, each with a corresponding compute node (compute-0, compute-1). These are connected to a Grandmaster Clock(s) block containing a Clock Source. The Data Network contains a Fronthaul Network block with PTP and T-BC/PTP Switch components. The Fronthaul Network is connected to multiple Cell Site (O-RU) blocks, each labeled with an 'S' for Slave. A legend indicates 'M' for Master and 'S' for Slave. + +**Figure 23: Hyperconverged Edge Cloud Time Sync Architecture for LLS-C3** + +##### 5.5.1.1.2 LLS-C3 Synchronization Topology Edge Site Requirements + +To support time synchronization at the Edge site, the cloud platform (O-Cloud) used at the Edge site needs to support implementation of the PTP IEEE 1588-2008 (a.k.a. IEEE 1588 Version 2) standard. The compute nodes should meet the “Time and Frequency Synchronization Requirements” described in CUS specification [7]. The following software and hardware capabilities are required: + +###### 5.5.1.1.2.1 Software + +Support for PTP will be needed in all the Edge Site O-Cloud nodes that support compute roles and will run vO-DU service operating as a Slave Clock. The following PTP configuration options should be provided: + +- Network Transport – L2, UDPv4, UDPv6 +- Delay Measurement Mechanism – utilize E2E to measure the delay +- Time Stamping – support for hardware time stamping + +For example: in the case when an O-Cloud is based on the Linux OS, this will require support for Linux PTP (see <http://linuxptp.sourceforge.net>) with the following: + +- ptp4l – implementation of PTP (Ordinary Clock, Boundary Clock), HW timestamping, E2E delay measurement mechanism. +- phc2sys – Synchronization of two clocks, PHC and system clock (Linux clock) when using HW timestamping + +###### 5.5.1.1.2.2 Hardware + +Use of High speed, low latency Network Interface Card (NIC) with support for PTP Hardware Clock (PHC) subsystem for the data interface (fronthaul) on all the compute node(s) that will run the vO-DU function. When vO-DU requires SyncE, the NIC must support it. + +#### 5.5.1.2 Edge Cloud Site Level – LLS-C1 Synchronization Topology + +This section outlines what the time synchronization architecture should be from the cloud platform perspective and identifies requirements that the Cloud Platform and Edge Site need to support in order to support the O-RAN deployment scenarios that use the LLS-C1 synchronization topology described in CUS specification [7]. + +##### 5.5.1.2.1 LLS-C1 Synchronization Topology Edge Site Time Synchronization Architecture + +The deployment architecture at the Edge Cloud site level includes: + +- Primary Reference Time Clock (PRTC)-traceable time source (i.e., Grandmaster Clocks): + - External precision time source for the PTP networks, usually based on Global Navigation Satellite System/Global Positioning System (GNSS/GPS) + +- Compute Nodes: + - Compute Node as acts synchronization master towards the fronthaul interface +- Controller Nodes: + - Controller Nodes synchronize their clocks to the Network Time Protocol (NTP) via the Management Network + +Figure 24 illustrates the relationship of these entities where the Controller functions are hosted on separate nodes from the Compute nodes. Figure 25 illustrates the relationships where each Compute node also includes the Controller functions (i.e., the hyperconverged case). + +![Diagram of LLS-C1 PTP Deployment Architecture showing Management Network, Data Network, and Cell Site components.](00cd1d2c88add94d3a71d753784c4d9f_img.jpg) + +### LLS-C1 PTP Deployment Architecture + +The diagram illustrates the LLS-C1 PTP Deployment Architecture. It is divided into three main sections: Management Network, Data Network, and Cell Site. + +- Management Network:** Contains the O-Cloud Management (OCM) block. Inside this block, there are multiple controller nodes labeled 'controller-0', '...', and 'controller-N'. These controllers are connected to an NTP (Network Time Protocol) block. +- Data Network:** Contains the O-Cloud Compute Node block. Inside this block, there is a 'compute-0' node. The 'compute-0' node is connected to the controller nodes in the Management Network. Below the 'compute-0' node, there is a label 'M PTP+SyncE'. +- Cell Site:** Contains the S PTP Cell Site (O-RU) block. This block is connected to the 'compute-0' node in the Data Network. +- GNSS:** A GNSS (Global Navigation Satellite System) icon is shown on the right side of the diagram, connected to the 'compute-0' node. +- Legend:** A legend on the right side of the diagram shows two circles: a purple circle labeled 'M' for Master and a blue circle labeled 'S' for Slave. + +Diagram of LLS-C1 PTP Deployment Architecture showing Management Network, Data Network, and Cell Site components. + +Figure 24: Edge Cloud Site Time Sync Architecture for LLS-C1 + +###### LLS-C1 PTP Deployment Architecture - Hyperconverged + +![Figure 25: Hyperconverged Edge Cloud Time Sync Architecture for LLS-C1. The diagram shows a Management Network and a Data Network. The Management Network contains an O-Cloud Hyperconverged block, which includes controller-0 and compute-0. The compute-0 block is labeled M PTP+SyncE. A GNSS satellite is connected to the Management Network. A legend indicates M for Master and S for Slave. The Data Network is connected to the compute-0 block, which is connected to an S PTP Cell Site (O-RU).](17e5e622f4efba5964f994613412499a_img.jpg) + +Figure 25: Hyperconverged Edge Cloud Time Sync Architecture for LLS-C1. The diagram shows a Management Network and a Data Network. The Management Network contains an O-Cloud Hyperconverged block, which includes controller-0 and compute-0. The compute-0 block is labeled M PTP+SyncE. A GNSS satellite is connected to the Management Network. A legend indicates M for Master and S for Slave. The Data Network is connected to the compute-0 block, which is connected to an S PTP Cell Site (O-RU). + +**Figure 25: Hyperconverged Edge Cloud Time Sync Architecture for LLS-C1** + +##### 5.5.1.2.2 LLS-C1 Synchronization Topology Edge Site Requirements + +To support time synchronization at the Edge site, the cloud platform (O-Cloud) used at the Edge site needs to support implementation of the PTP IEEE 1588-2008 (a.k.a. IEEE 1588 Version 2) standard. The compute nodes should meet the “Time and Frequency Synchronization Requirements” described in CUS specification [7]. The following software and hardware capabilities are required: + +###### 5.5.1.2.2.1 Software + +Support for PTP will be needed in all the Edge Site O-Cloud node that supports compute role and will run vO-DU service operating as a Master Clock. The following PTP configuration options should be provided: + +- Network Transport – L2, UDPv4, UDPv6 +- Delay Measurement Mechanism – utilize E2E to measure the delay +- Time Stamping – support for hardware time stamping + +###### 5.5.1.2.2.2 Hardware + +Use of High speed, low latency Network Interface Card (NIC) with support for PTP Hardware Clock (PHC) subsystem for the data interface (fronthaul) on all the compute node(s) that will run the vO-DU function. + +When vO-DU requires SyncE, the NIC must support it. + +### 5.5.2 Loss of Synchronization Notification + +Applications that rely on a Precision Time Protocol for synchronization (such as vO-DU but not limited to) should have the ability to retrieve the relevant data that can indicate the status of the PHC clock related to the worker node that the application is running on (for example a source clock class). Once an application subscribes to PTP notifications it receives the initial data which shows the PHC synchronization state and it will receive notifications when there is a state change to the sync status and/or per request for notification (pull), please refer to the notification subscription framework (section 5.4.5) how to subscribe for a PTP Notification. + +Rationale - The CUS specification [7] section 9.4.2, specifies various behaviours related to the state of the vO-DU and O-RU time synchronization. + +- For example, if an vO-DU transits to the FREERUN state, because the synchronizing network delivers unacceptable synchronization quality, the vO-DU shall disable RF transmission on all connected O-RUs, and keep it turned off until synchronization is reacquired again. + +It should be noted that since vO-DU may need to take an action upon the synchronization notification (see example above) it is required to handle these notifications at the scope of the edge cloud (at the site location where the vO-DU is running) for two main reasons: ensuring that the vO-DU receives the notifications regardless of the communication state of its backhaul link and reducing the round trip delay for notifying the vO-DU. + +Figure 26 illustrates an vO-DU subscribes to retrieve PTP Notification based on the subscription framework described at section 5.4.5. + +![Figure 26: vO-DU Subscribes to PTP Notification. The diagram shows the interaction between a vO-DU and the Edge Cloud. The vO-DU (O-vDU #0) is connected to a compute-0 block which contains a PTP Resource State and a PTP NIC. The Edge Cloud contains three main functions: registration function, notification function, and tracking function. The registration function sends a 'Reg Update' to the notification function. The notification function sends a 'Change in PTP State OR Pull' to the tracking function. The tracking function sends a 'Tracks PTP Sync status' to the vO-DU. The vO-DU sends 'App Queries & Subscribes to Available Notification(s)' to the registration function. A dashed line labeled 'PTP Push/Pull Notification' connects the vO-DU to the notification function.](99712893dc09ed4c8e384f854d7d86a7_img.jpg) + +``` + +graph TD + subgraph Edge_Cloud [Edge Cloud] + Reg[registration function] + Notif[notification function] + Track[tracking function] + end + vDU["O-vDU #0"] + compute0["compute-0"] + subgraph compute0_state [compute-0] + PTP_NIC[PTP NIC] + PTP_Resource[PTP Resource State] + end + + vDU -- "App Queries & Subscribes to Available Notification(s)" --> Reg + Reg -- "Reg Update" --> Notif + Notif -- "Change in PTP State OR Pull" --> Track + Track -- "Tracks PTP Sync status" --> vDU + vDU -.- "PTP Push/Pull Notification" -.- Notif + +``` + +Figure 26: vO-DU Subscribes to PTP Notification. The diagram shows the interaction between a vO-DU and the Edge Cloud. The vO-DU (O-vDU #0) is connected to a compute-0 block which contains a PTP Resource State and a PTP NIC. The Edge Cloud contains three main functions: registration function, notification function, and tracking function. The registration function sends a 'Reg Update' to the notification function. The notification function sends a 'Change in PTP State OR Pull' to the tracking function. The tracking function sends a 'Tracks PTP Sync status' to the vO-DU. The vO-DU sends 'App Queries & Subscribes to Available Notification(s)' to the registration function. A dashed line labeled 'PTP Push/Pull Notification' connects the vO-DU to the notification function. + +Note: The diagram shows the interaction and functionality from a logical perspective only but not where these functions reside or how they are implemented + +**Figure 26: vO-DU Subscribes to PTP Notification** + +## 5.6 Operations and Maintenance Considerations + +Management of cloudified RAN Network Functions introduces some new management considerations, because the mapping between Network Functionality and physical hardware can be done in multiple ways, depending on the Scenario that is chosen. Thus, management of aspects that are related to physical aspects rather than logical aspects need to be designed with flexibility in mind from the start. For example, logging of physical functions, scale out actions, and survivability considerations are affected. + +The O-RAN Alliance has defined key fundamentals of the OAM framework (see [8] and [9], and refer to Figure 1). Given the number of deployment scenario options and possible variations of O-RAN Managed Functions (MFs) being mapped into Managed Elements (MEs) in different ways, it is important for all MEs to support a consistent level of visibility and control of their contained Managed Functions to the Service Management & Orchestration Framework. This consistency will be enabled by support of the common OAM Interface Specification [9] for Fault Configuration Accounting Performance Security (FCAPS) and Life Cycle Management (LCM) functionality, and a common Information Modelling Framework that will provide underlying information models used for the MEs and MFs in a particular deployment. + +### 5.6.1 The O1 Interface + +As described in [8], the O1 is an interface between management entities in Service Management and Orchestration Framework and O-RAN managed elements, for operation and management, by which FCAPS management, Software management, File management shall be achieved. + +### 5.6.2 The O2 Interface + +The O2 Interface is a collection of services and their associated interfaces that are provided by the O-Cloud platform to the SMO. The services are categorized into two logical groups: + +- **Infrastructure Management Services:** which include the subset of O2 functions that are responsible for deploying and managing cloud infrastructure. +- **Deployment Management Services:** which include the subset of O2 functions that are responsible for managing the lifecycle of virtualized/containerized deployments on the cloud infrastructure. + +The O2 services and their associated interfaces shall be specified in the upcoming O2 specification. Any definitions of SMO functional elements needed to consume these services shall be described in OAM architecture. O2 interface would also address the management of hardware acceleration and supporting software in the O-Cloud platform. + +## 5.7 Transport Network Architecture + +While a Transport Network is a necessary foundation upon which to build any O-RAN deployment, a great many of the aspects of transport do not have to be addressed or specified in O-RAN Alliance documents. For example, any location with cloud servers will be connected by layer 2 or layer 3 switches, but we do not need to specify much if anything about them in this document. + +The transport media used, particularly for fronthaul, can have an effect on aspects such as performance. However, in the current version of this document we have been assuming that fiber transport is used. + +*Editor's Note: Other transport technologies (e.g., microwave) are also possible, and could be addressed at a later date.* + +That said, the use of an (optional) Fronthaul Gateway (FHGW)/Fronthaul Multiplexer (FHM) will have noteworthy effects on any O-RAN deployment that uses it. + +The use of a FHGW or FHM depends on whether protocol translation between O-DU and O-RU is necessary [15]. + +Fronthaul Gateway translates fronthaul protocol from an O-DU<sub>x</sub> with split option x to an O-RU<sub>y</sub> with split option y, wherein currently the translation between option 7-2→8 is available. A Fronthaul Multiplexer does not translate between fronthaul split options, i.e., both O-DU<sub>x</sub> and O-RU<sub>x</sub> necessarily support the same split option x; currently options 6→6, 7-2→7-2 and 8→8 are available. + +### 5.7.1 Fronthaul Gateways/Fronthaul Multiplexers + +In the deployment scenarios that follow, when the O-DU and O-RU functions are not implemented in the same physical node, a Fronthaul Gateway/Fronthaul Multiplexer is shown as an *optional* element between them. A Fronthaul Gateway/Fronthaul Multiplexer can be motivated by different factors depending on a carrier's deployment and may perform different functions. + +The O-RAN Alliance does not currently have a single definition of a Fronthaul Gateway, and this document does not attempt to define one. However, the Fronthaul Gateway/Fronthaul Multiplexer is included in the diagrams as an optional implementation to acknowledge the fact that carriers are considering Fronthaul Gateways/Fronthaul Multiplexer in their plans. Below are some examples of the functionality that could be provided: + +- A FHGW can convert CPRI connections to the node supporting the O-RU function to eCPRI connections to the node that provides O-DU functionality. + - Note that when there is no FHGW, it is assumed that the Open Fronthaul interface between the O-RU and O-DU uses Option 7-2, as mentioned earlier in Section 4.1. When there is a FHGW, it may have an Option 7-2 interface to both the O-DU and the O-RU, but it is also possible for the FHGW to have a different interface to the O-RU/RU; for example, where CPRI is supported. +- A FHGW/FHM can support the aggregation of fiber pairs. +- A FHGW/FHM must support the following forwarding functions: + - Downlink: Transport the traffic from O-DU to each O-RU (and cascading FHGW/FHM, if present) + +- Uplink: Summation of traffic from O-RUs +- A FHGW/FHM can provide power to the NEs supporting the O-RU function, e.g. via Power over Ethernet (PoE) or hybrid cable/fibers + +## 5.8 Overview of Deployment Scenarios + +The description of logical functionality in O-RAN includes the definition of key interfaces E2, F1, and Open Fronthaul. However, as noted earlier, this does not mean that each Network Function block must be implemented in a separate O-RAN Physical NF/O-RAN Cloudified NF. Multiple logical functions can be implemented in a single O-RAN Physical NF/O-RAN Cloudified NF (for example O-DU and O-RU may be packaged as a single appliance). + +We assume that when Network Functions are implemented as different O-RAN Physical NFs/O-RAN Cloudified NFs, the interfaces between them must conform to the O-RAN specifications. However, when multiple Network Functions are implemented by a single O-RAN Physical NF/O-RAN Cloudified NF, it is up to the operator to decide whether to enforce the O-RAN interfaces between the embedded Network Functions. However, note that the OAM requirements for each separate Network Function will still need to be met. + +The current deployment scenarios for discussion are summarized in the figure below. This includes options that are deployable in both the short and long term. Each will be discussed in some detail in the following sections, followed by a summary of which one or ones are candidates for initial focus. Please note that, to help ease the high-level depiction of functionality, a single O-CU box is shown with an F1 interface, but in detailed discussions of specific scenarios, this will need to be discussed properly as composed of an O-CU-CP function with an F1-c interface and an O-CU-UP function with an F1-u interface. Furthermore, there would in general be an unequal number of O-CU-CP and O-CU-UP instances. + +Figure 27 below shows the Network Functions at the top, and each identified scenario shows how these Network Functions are deployed as O-RAN Physical NFs or as O-RAN Cloudified NFs running on an O-RAN compliant O-Cloud. The term O-Cloud is defined in Section 4. Please note that the requirements for an O-Cloud are driven by the Network Functions that need to be supported by the hardware, so for instance an O-Cloud that supports an O-RU function would be different from an O-Cloud that supports O-CU functionality. + +Finally, note that in the high-level figure below, the User Plane (UP) traffic is shown being delivered to the UPF. As will be discussed, in specific scenarios it is sometimes possible for UP traffic to be delivered to edge applications that are supported by Mobile Edge Computing (MEC). However, note that the specification of MEC itself is out of scope of this document. + +Note that vendors are not required to support all scenarios – it is a business decision to be made by each vendor. Similarly, each operator will decide which scenarios it wishes to deploy. + +![Figure 27: High-Level Comparison of Scenarios. This diagram illustrates various deployment scenarios for O-RAN Network Functions (NFs). At the top, a logical architecture shows the UPF connected to a Near-RT RIC, which interfaces with O-CU via E2. O-CU interfaces with O-DU via F1, and O-DU interfaces with O-RU via Open Fronthaul. Below this, six scenarios (A through F) are shown, each depicting the physical placement of O-CU, O-DU, and O-RU. Scenarios A, B, and C show O-CU and O-DU on O-Clouds (Regional or Edge) and O-RU as a physical NF at the Cell Site. Scenario D shows O-CU and O-DU as physical NFs at the Cell Site, with O-RU also as a physical NF. Scenario E shows O-CU and O-DU as physical NFs at the Cell Site, with O-RU as a physical NF. Scenario F shows O-CU and O-DU as physical NFs at the Cell Site, with O-RU as a physical NF. A key on the right explains the symbols: 'O-Cloud' indicates an O-RAN Cloud Platform used to support RAN functions, optionally with hardware accelerators; 'O-RAN Physical NF' indicates a physical Network Function; and 'O-Cloud & optional O-RAN Physical NF' indicates a physical NF running on an O-Cloud. The key also notes that O-Clouds use open interfaces and can be 100% O-RAN Physical NF (potentially in an open chassis, open HW design).](b095e9af5e890100bcb209c62748dee4_img.jpg) + +Figure 27: High-Level Comparison of Scenarios. This diagram illustrates various deployment scenarios for O-RAN Network Functions (NFs). At the top, a logical architecture shows the UPF connected to a Near-RT RIC, which interfaces with O-CU via E2. O-CU interfaces with O-DU via F1, and O-DU interfaces with O-RU via Open Fronthaul. Below this, six scenarios (A through F) are shown, each depicting the physical placement of O-CU, O-DU, and O-RU. Scenarios A, B, and C show O-CU and O-DU on O-Clouds (Regional or Edge) and O-RU as a physical NF at the Cell Site. Scenario D shows O-CU and O-DU as physical NFs at the Cell Site, with O-RU also as a physical NF. Scenario E shows O-CU and O-DU as physical NFs at the Cell Site, with O-RU as a physical NF. Scenario F shows O-CU and O-DU as physical NFs at the Cell Site, with O-RU as a physical NF. A key on the right explains the symbols: 'O-Cloud' indicates an O-RAN Cloud Platform used to support RAN functions, optionally with hardware accelerators; 'O-RAN Physical NF' indicates a physical Network Function; and 'O-Cloud & optional O-RAN Physical NF' indicates a physical NF running on an O-Cloud. The key also notes that O-Clouds use open interfaces and can be 100% O-RAN Physical NF (potentially in an open chassis, open HW design). + +Figure 27: High-Level Comparison of Scenarios + +Each scenario is discussed in the next section. + +# 6 Deployment Scenarios and Implementation Considerations + +This section reviews each of the deployment scenarios in turn. For a given scenario, the requirements that apply to the O-RAN Physical NFs, O-RAN Cloudified NFs or O-Cloud platforms may become more specific and unique, while many of the logical Network Function requirements will remain the same. + +Please note that in all of the scenario figures of this section, the interfaces are logical interfaces (e.g., F1, E2, etc.). This has a couple of implications. First, the two functions on each side of an interface could be on different devices separated by physical transport connections (e.g., fiber or Ethernet transport connections), could be on different devices within the same cloud platform, or could even exist within the same server. Second, the functions on each side of an interface could be from the same vendor or different vendors. + +In addition, please note that all User Plane interfaces are shown with a solid lines, and all Control Plane interfaces use dashed lines. + +*Editor's note: The terms vO-CU and vO-DU represent virtualized or containerized O-CU and O-DU, and are used interchangeably with O-CU and O-DU in these scenarios (with the exception when the O-DU is explicitly stated as a non-virtualized O-DU).* + +## 6.1 Scenario A + +In this scenario, the near-RT RIC, O-CU, and O-DU functions are all virtualized on the same cloud platform, and interfaces between those functions are within the same cloud platform. + +This scenario supports deployments in dense urban areas with an abundance of fronthaul capacity that allows BBU functionality to be pooled in a central location with sufficiently low latency to meet the O-DU latency requirements. Therefore, it does not attempt to centralize the near-RT RIC more than the limit that O-DU functionality can be centralized. + +![Figure 28: Scenario A architecture diagram. The diagram shows an 'Edge cloud' (Open chassis and blade spec) containing a 'Cloud Platform' with 'Near-RT RIC', 'vO-CU', and 'vO-DU' blocks. The 'Near-RT RIC' is connected to 'UPF, MEC' via a red arrow. 'vO-CU' and 'vO-DU' are connected via 'E2' (dashed line) and 'F1' (solid line) interfaces. The 'vO-DU' is connected to an 'O-RU (/RU)' block via an 'Open fronthaul' (solid line). An optional 'FHGW/FHM (Opt)' block is shown between the 'vO-DU' and the 'O-RU (/RU)'. The 'O-RU (/RU)' is labeled 'Cell site'.](aca3071c37b85b6ad6ee8ceec9363c6f_img.jpg) + +Figure 28: Scenario A architecture diagram. The diagram shows an 'Edge cloud' (Open chassis and blade spec) containing a 'Cloud Platform' with 'Near-RT RIC', 'vO-CU', and 'vO-DU' blocks. The 'Near-RT RIC' is connected to 'UPF, MEC' via a red arrow. 'vO-CU' and 'vO-DU' are connected via 'E2' (dashed line) and 'F1' (solid line) interfaces. The 'vO-DU' is connected to an 'O-RU (/RU)' block via an 'Open fronthaul' (solid line). An optional 'FHGW/FHM (Opt)' block is shown between the 'vO-DU' and the 'O-RU (/RU)'. The 'O-RU (/RU)' is labeled 'Cell site'. + +Figure 28: Scenario A + +The choice between FHGW and FHM, as represented in Figure 28, depends on whether protocol translation between O-DU and O-RU/RU is necessary. + +Also please note that if the optional FHGW is present, the interface between it and the Radio Unit might not meet the O-RAN Fronthaul requirements (e.g., it might be an Option 8 interface), in which case the Radio Unit could be referred to as an “RU”, not an “O-RU”. However, if FHGWs are defined to support an interface such as Option 8, it could be argued that the O-RU definition at that time will support Option 8. + +### 6.1.1 Key Use Cases and Drivers + +*Editor's Note: This section is FFS.* + +## 6.2 Scenario B + +In this scenario, the near-RT RIC Network Function is virtualized on a Regional Cloud Platform, and the O-CU and O-DU functions are virtualized on an Edge Cloud hardware platform that in general will be at a different location. The interface between the Near-RT RIC network function and the O-CU/O-DU network functions is E2. Interfaces between the O-CU and O-DU Network Functions are within the same Cloud Platform. + +![Figure 29: Scenario B – NR Stand-alone architecture diagram.](a86530966260e7a888d5b4a0e9f85a58_img.jpg) + +The diagram illustrates the architecture for Scenario B – NR Stand-alone. It is divided into three main sections: Regional cloud, Edge cloud, and Cell site. + +- Regional cloud:** Contains a 'Near-RT RIC' and a 'Cloud Platform'. It is connected to the Edge cloud via a '1:L E2 E2' interface. +- Edge cloud:** Contains a 'vO-CU' and a 'vO-DU' within a 'Cloud Platform'. It is connected to the Regional cloud via the '1:L E2 E2' interface. It also connects to the Cell site via an 'Open fronthaul' interface, which includes an optional 'FHGW/FHM (Opt)' block. The interface is labeled '1:N'. +- Cell site:** Contains an 'O-RU (/RU)' block. + +Additional details include: + + +- A red arrow points from the 'vO-CU' in the Edge cloud to a 'UPF, MEC' block in the Regional cloud, labeled 'Open chassis and blade spec'. +- The 'vO-CU' and 'vO-DU' are connected via an 'F1' interface. +- The 'vO-CU' and 'vO-DU' are also connected via an 'Xn' interface. +- The 'vO-CU' and 'vO-DU' are connected via a 'W1(\*)' interface. +- The 'vO-CU' and 'vO-DU' are connected via an 'O-eNB' interface. +- The 'vO-CU' and 'vO-DU' are connected via an 'O-eNB' interface. + +Figure 29: Scenario B – NR Stand-alone architecture diagram. + +**Figure 29: Scenario B – NR Stand-alone** + +This scenario addresses deployments in locations with limited remote fronthaul capacity and O-RUs spread out in an area that limits the number of O-RUs that can be supported by pooled vO-CU/vO-DU functionality while still meeting the O-DU latency requirements. The use of a FHGW in the architecture allows significant savings in providing transport between the O-RU and vO-DU functionality. + +The choice between FHGW and FHM, as represented in Figure 29, depends on whether protocol translation between O-DU and O-RU/RU is necessary. + +![Figure 30: Scenario B – MR-DC (inter-RAT NR and E-UTRA) regardless of the Core Network type (either EPC or 5GC) architecture diagram.](920674382dd86f548a644c9a5f35a6a9_img.jpg) + +The diagram illustrates the architecture for Scenario B – MR-DC (inter-RAT NR and E-UTRA) regardless of the Core Network type (either EPC or 5GC). It is divided into three main sections: Regional cloud, Edge cloud, and Cell site. + +- Regional cloud:** Contains a 'Near-RT RIC' and a 'Cloud Platform'. It is connected to the Edge cloud via a '1:L E2 E2' interface. +- Edge cloud:** Contains a 'vO-CU<sub>N</sub>' and a 'vO-DU<sub>N</sub>' within a 'Cloud Platform'. It is connected to the Regional cloud via the '1:L E2 E2' interface. It also connects to the Cell site via an 'Open fronthaul' interface, which includes an optional 'FHGW/FHM (Opt)' block. The interface is labeled '1:N'. +- Cell site:** Contains an 'O-RU<sub>N</sub> (/RU<sub>N</sub>)' block. + +Additional details include: + + +- A red arrow points from the 'vO-CU<sub>N</sub>' in the Edge cloud to a 'UPF, MEC' block in the Regional cloud, labeled 'Open chassis and blade spec'. +- The 'vO-CU<sub>N</sub>' and 'vO-DU<sub>N</sub>' are connected via an 'F1' interface. +- The 'vO-CU<sub>N</sub>' and 'vO-DU<sub>N</sub>' are also connected via an 'Xn' interface. +- The 'vO-CU<sub>N</sub>' and 'vO-DU<sub>N</sub>' are connected via a 'W1(\*)' interface. +- The 'vO-CU<sub>N</sub>' and 'vO-DU<sub>N</sub>' are connected via an 'O-eNB' interface. +- The 'vO-CU<sub>N</sub>' and 'vO-DU<sub>N</sub>' are connected via an 'O-eNB' interface. + +Figure 30: Scenario B – MR-DC (inter-RAT NR and E-UTRA) regardless of the Core Network type (either EPC or 5GC) architecture diagram. + +**Figure 30: Scenario B – MR-DC (inter-RAT NR and E-UTRA) regardless of the Core Network type (either EPC or 5GC)** + +An Alternative to NR Standalone scenario B is given by the MR-DC (inter-RAT NR/E-UTRA) scenarios which extend requirements on the cloud platform to additionally support E-UTRA network functions (subscript E) and required interfaces Xn, open fronthaul and W1. The W1 interface, defined in 3GPP TS 37.470, only applies to E-UTRA nodes connected to 5G Core Network, i.e., ng-eNB as defined in 3GPP TS 38.300 and TS 38.401. Moreover, the foreseen MR-DC (inter-RAT NR/E-UTRA) scenarios also include the EPC-connected E-UTRA-NR Dual Connectivity (EN-DC) by properly replacing the Xn interface with the X2 interface interconnecting E-UTRA nodes (eNBs) and NR ones (en-gNBs), with the possibility to exploit vO-CU/vO-DU functional split only for the en-gNBs<sup>6</sup>. + +As discussed earlier in Section 5.1.3, the O-CU and O-DU functions can be virtualized using either simple centralization or pooled centralization. The desire is to have support for pooled centralization, although we need to understand what needs to be developed to enable such sharing. Perhaps pooling will be a later feature, but any initial solution should not preclude a future path to a pooled solution. + +The choice between FHGW and FHM, as represented in Figure 30, depends on whether protocol translation between O-DU and O-RU/RU is necessary. + +### 6.2.1 Key Use Cases and Drivers + +In this case, there are multiple O-RUs distributed in an area served by a centralized vO-DU functionality that can meet the latency requirements. Depending on the concentration of the O-RUs, N could vary, but in general is expected to be engineered to support < 64 TRPs per O-DU.<sup>7</sup> The near-RT RIC is centralized further to allow for optimization based on a more global view (e.g., a single large metropolitan area), and to reduce the number of separate near-RT RIC instances that need to be managed. + +The driving use case for this is to support an outdoor deployment of a mix of Small Cells and Macro cells in a relatively dense urban setting. This can support mmWave as well as Sub-6 deployments. + +In this scenario, a given “virtual BBU” supports both vO-CU and vO-DU functions and can connect many O-RUs. Current studies show that savings from pooling are significant but level off once more than 64 Transmission Reception Points (TRPs) are pooled. This would imply N would be around 32-64. This deployment should support tens of thousands of O-RUs per near-RT RIC, so L could easily exceed 100. + +Below is a summary of the cardinality requirements assumed for this scenario. + +**Table 2: Cardinality and Delay Performance for Scenario B** + +| Attribute | RIC – O-CU | O-CU – O-DU | O-DU – O-RU/RU | +|---------------------|------------|-------------|----------------| +| Example Cardinality | L = 100+ | M=1 | N = 1-64 | + +## 6.3 Scenario C + +In this scenario, the near-RT RIC and O-CU Network Functions are virtualized on a Regional Cloud Platform with a general server hardware platform, and the O-DU Network Functions are virtualized on an Edge Cloud hardware platform that is expected to include significant hardware accelerator capabilities. Interfaces between the near-RT RIC and the O-CU network functions are within the same Cloud Platform. The interface between the Regional Cloud and the Edge cloud is F1, and an E2 interface from the near-RT RIC to the O-DU must also be supported. + +<sup>6</sup> O-eNB vO-CU<sub>E</sub>/vO-DU<sub>E</sub> split (foreseen in 3GPP), is pending O-RAN architecture alignment in wg1. + +<sup>7</sup> It is assumed that one O-RU is associated with one TRP. For example, if a cell site has three sectors, then each sector would have at least one TRP and hence at least three O-RUs. + +![Figure 31: Scenario C architecture diagram. It shows a Regional cloud (Open chassis and blade spec) containing a Near-RT RIC, vO-CU, and Cloud Platform. The vO-CU is connected to a UPF, MEC block. The Regional cloud is connected to an Edge cloud (Open chassis and blade spec) via an E2 interface (1:M). The Edge cloud contains a vO-DU and Cloud Platform. The vO-DU is connected to the Regional cloud via F1-c & F1-u interfaces. The Edge cloud is connected to a Cell site (O-RU (/RU)) via an Open fronthaul interface (1:N). An optional FHGW/FHM block is shown between the vO-DU and the O-RU.](696fcdb6c0a6a69d1e75488f9b0f8eef_img.jpg) + +Figure 31: Scenario C architecture diagram. It shows a Regional cloud (Open chassis and blade spec) containing a Near-RT RIC, vO-CU, and Cloud Platform. The vO-CU is connected to a UPF, MEC block. The Regional cloud is connected to an Edge cloud (Open chassis and blade spec) via an E2 interface (1:M). The Edge cloud contains a vO-DU and Cloud Platform. The vO-DU is connected to the Regional cloud via F1-c & F1-u interfaces. The Edge cloud is connected to a Cell site (O-RU (/RU)) via an Open fronthaul interface (1:N). An optional FHGW/FHM block is shown between the vO-DU and the O-RU. + +Figure 31: Scenario C + +This scenario is to support deployments in locations with limited remote Fronthaul capacity and O-RUs spread out in an area that limits the number of O-RUs that can be pooled while still meeting the O-DU latency requirements. It also applies to some whitebox macrocell deployments. The O-CU Network Function is further pooled to increase the efficiency of the hardware platform which it shares with the near-RT RIC Network Function. + +However, note that if a service type has tighter O-CU delay requirements than other services, then that may either severely limit the number of O-RUs supported by the Regional cloud, or a method will be needed to separate the processing of such services. This will be discussed further in the following C.1 and C.2 Scenarios. + +The use of a FH GW in the architecture allows significant savings in providing transport between the O-RU and vO-DU functionality. + +The choice between FHGW and FHM, as represented in Figure 31, depends on whether protocol translation between O-DU and O-RU/RU is necessary. + +### 6.3.1 Key Use Cases and Drivers + +In this case, there are multiple O-RUs distributed in an area where each O-RU can meet the latency requirement for the pooled vO-DU function. The near-RT RIC and O-CU Network Functions are further centralized to realize additional efficiencies. + +A use case for this is to support an outdoor deployment of a mix of Small Cells and Macro cells in a relatively dense urban setting. This can support mmWave as well as Sub-6 deployments. + +In this scenario, as in Scenario B, the Edge Cloud is expected to support roughly 32-64 O-RUs. This deployment should support tens of thousands of O-RUs per near-RT RIC. + +Below is a summary of the cardinality and the distance/delay requirements assumed for this scenario. + +Table 3: Cardinality and Delay Performance for Scenario C + +| Attribute | RIC – O-CU | O-CU – O-DU | O-DU – O-RU/RU | +|---------------------|------------|-------------|-----------------| +| Example Cardinality | L= 1 | M=100+ | N=Roughly 32-64 | + +### 6.3.2 Scenario C.1, and Use Case and Drivers + +This is a variation of Scenario C, driven by the fact that different types of traffic (network slices) have different latency requirements. In particular, URLLC has more demanding user-plane latency requirements, and Figure 32 below shows how the vO-CU User Part (vO-CU-UP) could be terminated in different places for different network slices. Below, network slice 3 is terminated in the Edge Cloud. This scenario is also suitable in case there isn't enough space or power supply to install all vO-CUs and vO-DUs in one Edge Cloud site. + +![Figure 32: Treatment of Network Slices: MEC for URLLC at Edge Cloud, Centralized Control, Single vO-DU. The diagram shows a 1:M relationship between a Regional Cloud and an Edge Cloud, and a 1:N relationship between the Edge Cloud and a Cell site. The Regional Cloud contains vO-CU-CP1 and vO-CU-UP1. The Edge Cloud contains vO-CU-UP2 and vO-DU. The Cell site contains O-RU. Three network slices are shown: Slice1 (mMTC), Slice2 (eMBB), and Slice3 (URLLC). Slice3 is associated with MEC at the Edge Cloud. Arrows indicate data flow between components and slices.](de553409fa4d0389bc673ca131864da8_img.jpg) + +Figure 32: Treatment of Network Slices: MEC for URLLC at Edge Cloud, Centralized Control, Single vO-DU. The diagram shows a 1:M relationship between a Regional Cloud and an Edge Cloud, and a 1:N relationship between the Edge Cloud and a Cell site. The Regional Cloud contains vO-CU-CP1 and vO-CU-UP1. The Edge Cloud contains vO-CU-UP2 and vO-DU. The Cell site contains O-RU. Three network slices are shown: Slice1 (mMTC), Slice2 (eMBB), and Slice3 (URLLC). Slice3 is associated with MEC at the Edge Cloud. Arrows indicate data flow between components and slices. + +**Figure 32: Treatment of Network Slices: MEC for URLLC at Edge Cloud, Centralized Control, Single vO-DU** + +In Scenario C.1, all O-CU control is placed in the Regional Cloud, and there is a single vO-DU for all Network Slices. Only the placement of the vO-CU-CP differs, depending on the network slice. Below is the diagram of this scenario, using the common diagram conventions of all scenarios. + +![Figure 33: Scenario C.1. This diagram illustrates the architecture for Scenario C.1. It shows a 1:M relationship between a Regional cloud and an Edge cloud, and a 1:N relationship between the Edge cloud and a Cell site. The Regional cloud contains a Near-RT RIC, vO-CU-CP, and vO-CU-UP1. The Edge cloud contains vO-CU-UP2 and vO-DU. The Cell site contains O-RU (/RU). Interfaces E1, E2, F1-c, F1-u, and F1-d are shown. An Open fronthaul interface (FHGW/FHM (Opt)) connects the Edge cloud to the Cell site. MEC for #1 is in the Regional cloud, and MEC for #2 is in the Edge cloud. The architecture is based on Open chassis and blade specifications.](bde09174f9ec7bf546d992a507721272_img.jpg) + +Figure 33: Scenario C.1. This diagram illustrates the architecture for Scenario C.1. It shows a 1:M relationship between a Regional cloud and an Edge cloud, and a 1:N relationship between the Edge cloud and a Cell site. The Regional cloud contains a Near-RT RIC, vO-CU-CP, and vO-CU-UP1. The Edge cloud contains vO-CU-UP2 and vO-DU. The Cell site contains O-RU (/RU). Interfaces E1, E2, F1-c, F1-u, and F1-d are shown. An Open fronthaul interface (FHGW/FHM (Opt)) connects the Edge cloud to the Cell site. MEC for #1 is in the Regional cloud, and MEC for #2 is in the Edge cloud. The architecture is based on Open chassis and blade specifications. + +**Figure 33: Scenario C.1** + +Below is a summary of the cardinality and the distance/delay requirements assumed for this scenario. The URLLC user plane requirements are what drive the placement of the vO-CU-UP function to be in the Edge cloud. + +**Table 4: Cardinality and Delay Performance for Scenario C.1** + +| | Attribute | RIC – O-CU | O-CU – O-DU | O-DU – O-RU/RU | +|-------------------------------|----------------------|------------|--------------------------------|----------------| +| | Example Cardinality | L= 1 | M=320 | N=100 | +| Delay Max<br>1-way (distance) | mMTC | NA | 625 μs (125 km) | 100 μs (20 km) | +| | eMBB | NA | 625 μs (125 km) | 100 μs (20 km) | +| | URLLC (user/control) | NA | 100 μs (20 km)/625 μs (125 km) | 100 μs (20 km) | + +The choice between FHGW and FHM, as represented in Figure 33, depends on whether protocol translation between O-DU and O-RU/RU is necessary. + +### 6.3.3 Scenario C.2, and Use Case and Drivers + +This is a second variation of Scenario C, which utilizes the same method of placing some vO-CU user plane functionality in the Edge Cloud, and some in the Regional Cloud. However, instead of having one vO-DU for all network slices, there are different vO-DU instances in the Edge Cloud. + +It is driven by factors including the following two use cases: + +- One driver is RAN (O-RU) sharing among operators. In this use case, any operator can flexibly launch vO-CU and vO-DU instances at Edge or Regional Cloud site. For example, as shown in Figure 34, Operator #1 wants to launch the vO-CU1 instance in the Regional Cloud, and the vO-DU1 instance at subtending Edge Cloud sites. On the other hand, Operator #2 wants to install both the vO-CU2 and vO-DU2 instances at the same Regional Cloud site. Note that both operators will share the O-RU). +- Another driver is that, even within a single operator, that operator can customize scheduler functions depending on the network slice types and can place the vO-CU and vO-DU instances depending on the network slice types. For example, an operator may launch both vO-CU and vO-DU at the edge cloud site (see Operator #2 below) to provide a URLLC service. + +![Figure 34: Treatment of Network Slice: MEC for URLLC at Edge Cloud, Separate vO-DUs. The diagram shows a multi-operator architecture. At the top, three cloud sites are connected: Regional Cloud, Edge Cloud, and Cell site. The Regional Cloud contains vO-CU1 for Operator #1 and vO-CU2 for Operator #2. The Edge Cloud contains vO-DU1 for Operator #1 and vO-DU2 for Operator #2. Both vO-CU instances are connected to a UPF, MEC block. The vO-DU instances are connected to an O-RU at the Cell site. The O-RU is shared by both operators. Three network slices are shown: Slice1 (mMTC) in blue, Slice2 (eMBB) in green, and Slice3 (URLLC) in orange. The O-RU is connected to these slices. The diagram also shows 1:M and 1:N connections between the cloud sites.](a74539572e5d089b7db6aa6d8bda124c_img.jpg) + +Figure 34: Treatment of Network Slice: MEC for URLLC at Edge Cloud, Separate vO-DUs. The diagram shows a multi-operator architecture. At the top, three cloud sites are connected: Regional Cloud, Edge Cloud, and Cell site. The Regional Cloud contains vO-CU1 for Operator #1 and vO-CU2 for Operator #2. The Edge Cloud contains vO-DU1 for Operator #1 and vO-DU2 for Operator #2. Both vO-CU instances are connected to a UPF, MEC block. The vO-DU instances are connected to an O-RU at the Cell site. The O-RU is shared by both operators. Three network slices are shown: Slice1 (mMTC) in blue, Slice2 (eMBB) in green, and Slice3 (URLLC) in orange. The O-RU is connected to these slices. The diagram also shows 1:M and 1:N connections between the cloud sites. + +**Figure 34: Treatment of Network Slice: MEC for URLLC at Edge Cloud, Separate vO-DUs** + +The multi-Operator use case has the following pros and cons: + +Pros: + +- O-RU sharing can reduce TCO +- Flexible CU/DU location allows deployments to consider not only service requirements but also limitations of space or power in each site + +Cons: + +- Allowing multiple operators to share O-RU resources is expected to require changes to the Open Fronthaul interface (especially the handshake among more than one vO-DU and a given O-RU). +- This change seems likely to have M-plane specification impact. Therefore, this approach would need O-RAN buy-in and approval. + +Figure 35 below illustrates how different Component Carriers can be allocated to different operators, at the same O-RU *at the same time*. Note that some updates of not only M-plane but also CUS-plane specifications will be required when considering frequency resource sharing among DUs. + +![Figure 35: Single O-RU Being Shared by More than One Operator. The diagram shows a multi-operator architecture. At the top, three cloud sites are connected: Regional Cloud, Edge Cloud, and Cell site. The Regional Cloud contains vO-CU1 for Operator #1 and vO-CU2 for Operator #2. The Edge Cloud contains vO-DU1 for Operator #1 and vO-DU2 for Operator #2. Both vO-CU instances are connected to a UPF, MEC block. The vO-DU instances are connected to an L2 SW block, which is connected to an O-RU at the Cell site. The O-RU is shared by both operators. The diagram also shows F1 connections between the vO-CU and vO-DU instances. A dashed line labeled 'Different CC allocation' points to a frequency resource allocation diagram at the bottom. This diagram shows a frequency band 'f' divided into three blocks, each labeled 'BW' and 'Component Carrier'.](ebebbec8741470c66cafe9a52547e899_img.jpg) + +Figure 35: Single O-RU Being Shared by More than One Operator. The diagram shows a multi-operator architecture. At the top, three cloud sites are connected: Regional Cloud, Edge Cloud, and Cell site. The Regional Cloud contains vO-CU1 for Operator #1 and vO-CU2 for Operator #2. The Edge Cloud contains vO-DU1 for Operator #1 and vO-DU2 for Operator #2. Both vO-CU instances are connected to a UPF, MEC block. The vO-DU instances are connected to an L2 SW block, which is connected to an O-RU at the Cell site. The O-RU is shared by both operators. The diagram also shows F1 connections between the vO-CU and vO-DU instances. A dashed line labeled 'Different CC allocation' points to a frequency resource allocation diagram at the bottom. This diagram shows a frequency band 'f' divided into three blocks, each labeled 'BW' and 'Component Carrier'. + +**Figure 35: Single O-RU Being Shared by More than One Operator** + +The diagram of how Network Functions map to Networks Elements for Scenario C.2 is shown below. + +![Figure 36: Scenario C.2 architecture diagram. It shows a Regional cloud (left) with a Near-RT RIC and vO-CU1, connected via E2 and F1 interfaces to an Edge cloud (middle) with vO-CU2 and vO-DU1/vO-DU2. The Edge cloud is connected via an Open fronthaul (FHGW/FHM (Opt)) to a Cell site (right) with O-RU (/RU). Red arrows indicate connections from vO-CU1 to UPF, MEC for #1 and from vO-CU2 to UPF, MEC for #2. Labels include 'Open chassis and blade spec' for both clouds and '1:M' and '1:N' ratios.](55fd92ea1b3773552894f94e4791aa66_img.jpg) + +Figure 36: Scenario C.2 architecture diagram. It shows a Regional cloud (left) with a Near-RT RIC and vO-CU1, connected via E2 and F1 interfaces to an Edge cloud (middle) with vO-CU2 and vO-DU1/vO-DU2. The Edge cloud is connected via an Open fronthaul (FHGW/FHM (Opt)) to a Cell site (right) with O-RU (/RU). Red arrows indicate connections from vO-CU1 to UPF, MEC for #1 and from vO-CU2 to UPF, MEC for #2. Labels include 'Open chassis and blade spec' for both clouds and '1:M' and '1:N' ratios. + +**Figure 36: Scenario C.2** + +The performance requirements are the same as those discussed earlier for Scenario C.1 in Section 6.3.2. + +The choice between FHGW and FHM, as represented in Figure 36, depends on whether protocol translation between O-DU and O-RU/RU is necessary. + +## 6.4 Scenario D + +This scenario is a variation on Scenario C, but in this case the O-DU functionality is supported by an O-RAN Physical NF rather than an O-Cloud. + +The general assumption is that Scenario D has the same use cases and performance requirements as Scenario C, and the primary difference is in the business decision of how the O-RAN Physical NF based solution compares with the O-RAN compliant O-Cloud solution. Implementation considerations (discussed in Section 5.1) could lead a carrier to decide that an acceptable O-Cloud solution is not available in a deployment's timeframe. + +![Figure 37: Scenario D architecture diagram. It shows a Regional cloud (left) with a Near-RT RIC and vO-CU, connected via E2 and F1 interfaces to an Edge location (middle) with a Non virtualized O-DU. The Edge location is connected via an Open fronthaul (FHGW/FHM (Opt)) to a Cell site (right) with O-RU (/RU). A red arrow indicates a connection from vO-CU to UPF, MEC. Labels include 'Open chassis and blade spec' for both clouds and '1:M' and '1:N' ratios.](71e995dbebfdb3f543d6734fbcc4b2b0_img.jpg) + +Figure 37: Scenario D architecture diagram. It shows a Regional cloud (left) with a Near-RT RIC and vO-CU, connected via E2 and F1 interfaces to an Edge location (middle) with a Non virtualized O-DU. The Edge location is connected via an Open fronthaul (FHGW/FHM (Opt)) to a Cell site (right) with O-RU (/RU). A red arrow indicates a connection from vO-CU to UPF, MEC. Labels include 'Open chassis and blade spec' for both clouds and '1:M' and '1:N' ratios. + +**Figure 37: Scenario D** + +The choice between FHGW and FHM, as represented in Figure 37, depends on whether protocol translation between O-DU and O-RU/RU is necessary. + +## 6.5 Scenario E + +In contrast to Scenario D, this scenario assumes that not only can the O-DU be virtualized as in Scenario C, but that the O-RU can also be successfully virtualized. Furthermore, the O-RU and O-DU would be implemented in the same O-Cloud, which has acceleration hardware if required by either or both the O-RU and O-DU. + +Note, this seems to be a future scenario, and is not part of our initial focus. + +![Figure 38: Scenario E architecture diagram. It shows a 'Regional cloud' on the left containing a 'Near-RT RIC' and a 'vO-CU' block, both sitting on a 'Cloud Platform' which is labeled 'Open chassis and blade spec'. A red arrow points from the 'vO-CU' to a 'UPF, MEC' block. A dashed line labeled 'E2' connects the 'Near-RT RIC' to a 'Cell site' on the right. The 'Cell site' contains a 'vO-DU' and a 'vO-RU' block, also on a 'Cloud Platform' labeled 'Open chassis and blade spec'. A solid line labeled 'F1' connects the 'vO-CU' to the 'vO-DU'. Above the 'F1' line, the text '1:M' is present.](2aca22ae3dcc130118027fc1882e6b34_img.jpg) + +Figure 38: Scenario E architecture diagram. It shows a 'Regional cloud' on the left containing a 'Near-RT RIC' and a 'vO-CU' block, both sitting on a 'Cloud Platform' which is labeled 'Open chassis and blade spec'. A red arrow points from the 'vO-CU' to a 'UPF, MEC' block. A dashed line labeled 'E2' connects the 'Near-RT RIC' to a 'Cell site' on the right. The 'Cell site' contains a 'vO-DU' and a 'vO-RU' block, also on a 'Cloud Platform' labeled 'Open chassis and blade spec'. A solid line labeled 'F1' connects the 'vO-CU' to the 'vO-DU'. Above the 'F1' line, the text '1:M' is present. + +Figure 38: Scenario E + +### 6.5.1 Key Use Cases and Drivers + +Because the O-DU and O-RU are implemented in the same O-Cloud in this Scenario, it seems that the O-DU implementation must meet the environmental and accessibility requirements typically associated with an O-RU. Therefore, an indoor use case seems most appropriate. + +### 6.5.2 Scenario E.1 vO-DU with O-RU + +For Macrocell deployment with the Open Hardware approach that is used in WG7, the O-DU 7-2 of O-RAN WG7 OMAC HAR 0-v01.00 [13] can be a virtual function. In this small-scale scenario, HW acceleration is optional. The Cloud platform could be physically located near or at the bottom of the tower and be associated with a number of O-RUs implemented with the Open HW design, possibly but not necessarily in the same chassis. + +![Figure 39: Scenario E.1 architecture diagram. It shows a 'Regional cloud' on the left with a 'Near-RT RIC' and 'vO-CU' on a 'Cloud Platform' (labeled 'Open chassis and blade spec'). A red arrow points from 'vO-CU' to 'UPF, MEC'. A dashed 'E2' line connects 'Near-RT RIC' to a 'Cell site' on the right. The 'Cell site' contains a 'vO-DU' on a 'Cloud Platform' (labeled 'Open chassis and blade spec') and an 'O-RU (/RU)' block. A solid 'F1' line connects 'vO-CU' to 'vO-DU'. Above 'F1' is '1:M'. Between the 'vO-DU' and 'O-RU' is a dashed box labeled 'FHGW/FHM (Opt)' with the text 'Open fronthaul' above it. Above the 'O-RU' is '1:N'. Below the 'O-RU' is the text 'O-RU uses Open HW design'.](8115ced389b6a8c0418275401653b176_img.jpg) + +Figure 39: Scenario E.1 architecture diagram. It shows a 'Regional cloud' on the left with a 'Near-RT RIC' and 'vO-CU' on a 'Cloud Platform' (labeled 'Open chassis and blade spec'). A red arrow points from 'vO-CU' to 'UPF, MEC'. A dashed 'E2' line connects 'Near-RT RIC' to a 'Cell site' on the right. The 'Cell site' contains a 'vO-DU' on a 'Cloud Platform' (labeled 'Open chassis and blade spec') and an 'O-RU (/RU)' block. A solid 'F1' line connects 'vO-CU' to 'vO-DU'. Above 'F1' is '1:M'. Between the 'vO-DU' and 'O-RU' is a dashed box labeled 'FHGW/FHM (Opt)' with the text 'Open fronthaul' above it. Above the 'O-RU' is '1:N'. Below the 'O-RU' is the text 'O-RU uses Open HW design'. + +Figure 39: Scenario E.1 + +The choice between FHGW and FHM, as represented in Figure 39, depends on whether protocol translation between O-DU and O-RU/RU is necessary. + +## 6.6 Scenario F + +This is a variation on Scenario E in which the O-DU and O-RU are both virtualized, but in different O-Clouds. This means that: + +- The O-DU function can be placed in a more convenient location in terms of accessibility for maintenance and upgrades. +- The O-DU function can be placed in an environment that is semi-controlled or controlled, which reduces some of the implementation complexity. + +![Figure 40: Scenario F architecture diagram showing the flow from Regional cloud to Edge cloud to Cell site.](d302a24196034b009fe3b3e15c72650f_img.jpg) + +The diagram illustrates the architecture for Scenario F, showing the flow of data and control between three main components: Regional cloud, Edge cloud, and Cell site. + +- Regional cloud:** Contains a **UPF, MEC** block (purple) and a **Cloud Platform** block (blue). It also includes a **Near-RT RIC** block (blue) and a **vO-CU** block (blue). The **Near-RT RIC** and **vO-CU** are connected via an **E2** interface. +- Edge cloud:** Contains a **Cloud Platform** block (blue) and a **vO-DU** block (blue). It is connected to the **vO-CU** in the Regional cloud via an **F1** interface. +- Cell site:** Contains a **Cloud Platform** block (blue) and a **vO-RU** block (blue). It is connected to the **vO-DU** in the Edge cloud via an **Open fronthaul** interface, which is represented by a dashed box labeled **IFHGW/FHM (Opt)**. + +Additional labels and ratios: + +- 1:M E2:** Indicates the ratio between the **Near-RT RIC** and the **vO-CU**. +- 1:N:** Indicates the ratio between the **vO-DU** and the **vO-RU**. + +Figure 40: Scenario F architecture diagram showing the flow from Regional cloud to Edge cloud to Cell site. + +Figure 40: Scenario F + +### 6.6.1 Key Use Cases and Drivers + +Because this assumes that the O-RU is virtualized, this is a future use case. + +This use case seems to be better suited for outdoor deployments (e.g., pole mounted) than Scenario E. + +The choice between FHGW and FHM, as represented in Figure 40, depends on whether protocol translation between O-DU and O-RU is necessary. + +## 6.7 Scenarios of Initial Interest + +More scenarios have been identified than can be addressed in the initial release of this document. Scenario B has been selected as the one to address initially, and to be the subject of detailed treatment in a Scenario document (refer back to Figure 1). Other scenarios are expected to be addressed in later work. + +# 7 Appendix A (informative): Extensions to Current Deployment Scenarios to Include NSA + +In this appendix, some extensions to (some of) the current deployment scenarios are proposed with the aim of introducing Non-Standalone (NSA) in the pictures, consistently with the scope O-RAN cloud architecture. These extensions will be the basis of the discussion for next version of the present document. In the following charts the subscript 'N' is indicating blocks related to NR, while the subscript 'E' is indicating blocks related to E-UTRA.<sup>8</sup> For E-UTRA, the W1 interface is indicated. Its definition is ongoing in a 3GPP work item. + +<sup>8</sup> No UPF or MEC blocks are explicitly indicated in the figures of this appendix, as the focus of this appendix is on the radio part. + +## 7.1 Scenario A + +![Figure 41: Scenario A, Including NSA. This diagram illustrates the architecture of Scenario A. On the left, the 'Edge cloud' (Open chassis and blade spec) contains a 'Near-RT RIC' connected to 'vO-CU_N' and 'vO-CU_E' via E2 interfaces. 'vO-CU_N' is connected to 'vO-DU_N' via F1, and 'vO-CU_E' is connected to 'vO-DU_E' via F1. 'vO-DU_N' and 'vO-DU_E' are connected to each other via X2/Xn. Both 'vO-DU_N' and 'vO-DU_E' are connected to 'W1(*)' interfaces. The 'Cloud Platform' is at the bottom. On the right, the 'Cell site' shows two 'O-RU_N (/RU_N)' and 'O-RU_E (/RU_E)' units. Each is connected to an 'FHGW/FHM (Opt)' block via 'Open fronthaul' (1:N). The 'FHGW/FHM (Opt)' blocks are connected to the 'W1(*)' interfaces of the 'vO-DU' units via 'Open fronthaul' (1:N).](032b1a37d2cfee141dacddefb4d3ad3b_img.jpg) + +Open chassis and blade spec + +Edge cloud + +Cell site + +(\*) Pending 3GPP work completion on W1 + +Figure 41: Scenario A, Including NSA. This diagram illustrates the architecture of Scenario A. On the left, the 'Edge cloud' (Open chassis and blade spec) contains a 'Near-RT RIC' connected to 'vO-CU\_N' and 'vO-CU\_E' via E2 interfaces. 'vO-CU\_N' is connected to 'vO-DU\_N' via F1, and 'vO-CU\_E' is connected to 'vO-DU\_E' via F1. 'vO-DU\_N' and 'vO-DU\_E' are connected to each other via X2/Xn. Both 'vO-DU\_N' and 'vO-DU\_E' are connected to 'W1(\*)' interfaces. The 'Cloud Platform' is at the bottom. On the right, the 'Cell site' shows two 'O-RU\_N (/RU\_N)' and 'O-RU\_E (/RU\_E)' units. Each is connected to an 'FHGW/FHM (Opt)' block via 'Open fronthaul' (1:N). The 'FHGW/FHM (Opt)' blocks are connected to the 'W1(\*)' interfaces of the 'vO-DU' units via 'Open fronthaul' (1:N). + +Figure 41: Scenario A, Including NSA + +## 7.2 Scenario B + +Editor's Note: Scenario B, Including NSA has been incorporated into 6.2. + +## 7.3 Scenario C + +![Figure 42: Scenario C, Including NSA. This diagram illustrates the architecture of Scenario C. On the left, the 'Regional cloud' (Open chassis and blade spec) contains a 'Near-RT RIC' connected to 'vO-CU_N' and 'vO-CU_E' via E2 interfaces. 'vO-CU_N' is connected to 'vO-DU_N' via F1, and 'vO-CU_E' is connected to 'vO-DU_E' via F1. 'vO-DU_N' and 'vO-DU_E' are connected to each other via X2/Xn. Both 'vO-DU_N' and 'vO-DU_E' are connected to 'W1(*)' interfaces. The 'Cloud Platform' is at the bottom. In the middle, the 'Edge cloud' (Open chassis and blade spec) contains 'vO-DU_N' and 'vO-DU_E' connected to each other via X2/Xn. Both are connected to 'W1(*)' interfaces. The 'Cloud Platform' is at the bottom. On the right, the 'Cell site' shows two 'O-RU_N (/RU_N)' and 'O-RU_E (/RU_E)' units. Each is connected to an 'FHGW/FHM (Opt)' block via 'Open fronthaul' (1:N). The 'FHGW/FHM (Opt)' blocks are connected to the 'W1(*)' interfaces of the 'vO-DU' units via 'Open fronthaul' (1:N).](71f58913e01272d6e8c4c9bcc8d5afc0_img.jpg) + +Open chassis and blade spec + +Regional cloud + +Open chassis and blade spec + +Edge cloud + +Cell site + +(\*) Pending 3GPP work completion on W1 + +Figure 42: Scenario C, Including NSA. This diagram illustrates the architecture of Scenario C. On the left, the 'Regional cloud' (Open chassis and blade spec) contains a 'Near-RT RIC' connected to 'vO-CU\_N' and 'vO-CU\_E' via E2 interfaces. 'vO-CU\_N' is connected to 'vO-DU\_N' via F1, and 'vO-CU\_E' is connected to 'vO-DU\_E' via F1. 'vO-DU\_N' and 'vO-DU\_E' are connected to each other via X2/Xn. Both 'vO-DU\_N' and 'vO-DU\_E' are connected to 'W1(\*)' interfaces. The 'Cloud Platform' is at the bottom. In the middle, the 'Edge cloud' (Open chassis and blade spec) contains 'vO-DU\_N' and 'vO-DU\_E' connected to each other via X2/Xn. Both are connected to 'W1(\*)' interfaces. The 'Cloud Platform' is at the bottom. On the right, the 'Cell site' shows two 'O-RU\_N (/RU\_N)' and 'O-RU\_E (/RU\_E)' units. Each is connected to an 'FHGW/FHM (Opt)' block via 'Open fronthaul' (1:N). The 'FHGW/FHM (Opt)' blocks are connected to the 'W1(\*)' interfaces of the 'vO-DU' units via 'Open fronthaul' (1:N). + +Figure 42: Scenario C, Including NSA + +## 7.4 Scenario C.2 + +The scenario addresses both the single and multi-operator cases. To reduce the complexity in the figure the multi operator case is considered, so no X2/Xn interface is present between CU<sub>N1</sub> and CU<sub>E2</sub> or between CU<sub>E1</sub> and CU<sub>N2</sub>. + +![Figure 43: Scenario C.2, Including NSA. This diagram illustrates a multi-tier network architecture. On the left, the 'Regional cloud' contains a 'Near-RT RIC' and 'vO-CU_N1' connected via E2 and F1 interfaces, and 'vO-CU_E1' connected via X2/Xn and W1(*) interfaces. This connects to the 'Edge cloud' which contains 'vO-CU_N2' and 'vO-DU_N1' connected via F1, and 'vO-CU_E2' and 'vO-DU_E1' connected via X2/Xn and W1(*) interfaces. The edge cloud connects to the 'Cell site' via 'Open fronthaul' (FHGW/FHM (Opt)) to 'O-RU_N (/RU_N)' and 'O-RU_E (/RU_E)'. Ratios 1:M and 1:N are indicated between the clouds and cell sites respectively.](4d74c292e5727a2f1e3ff37a2b42f46b_img.jpg) + +Figure 43: Scenario C.2, Including NSA. This diagram illustrates a multi-tier network architecture. On the left, the 'Regional cloud' contains a 'Near-RT RIC' and 'vO-CU\_N1' connected via E2 and F1 interfaces, and 'vO-CU\_E1' connected via X2/Xn and W1(\*) interfaces. This connects to the 'Edge cloud' which contains 'vO-CU\_N2' and 'vO-DU\_N1' connected via F1, and 'vO-CU\_E2' and 'vO-DU\_E1' connected via X2/Xn and W1(\*) interfaces. The edge cloud connects to the 'Cell site' via 'Open fronthaul' (FHGW/FHM (Opt)) to 'O-RU\_N (/RU\_N)' and 'O-RU\_E (/RU\_E)'. Ratios 1:M and 1:N are indicated between the clouds and cell sites respectively. + +Figure 43: Scenario C.2, Including NSA + +## 7.5 Scenario D + +![Figure 44: Scenario D, Including NSA. This diagram shows a simplified architecture. The 'Regional cloud' contains a 'Near-RT RIC' and 'vO-CU_N' connected via E2 and F1, and 'vO-CU_E' connected via X2/Xn and W1(*) interfaces. The 'Edge location' contains 'Non virtualized O-DU_N' and 'Non virtualized O-DU_E'. The 'Cell site' contains 'O-RU_N (/RU_N)' and 'O-RU_E (/RU_E)' connected via 'Open fronthaul' (FHGW/FHM (Opt)). Ratios 1:M and 1:N are indicated.](37e6d0b0d8dfea7db6a15681f108d7a5_img.jpg) + +Figure 44: Scenario D, Including NSA. This diagram shows a simplified architecture. The 'Regional cloud' contains a 'Near-RT RIC' and 'vO-CU\_N' connected via E2 and F1, and 'vO-CU\_E' connected via X2/Xn and W1(\*) interfaces. The 'Edge location' contains 'Non virtualized O-DU\_N' and 'Non virtualized O-DU\_E'. The 'Cell site' contains 'O-RU\_N (/RU\_N)' and 'O-RU\_E (/RU\_E)' connected via 'Open fronthaul' (FHGW/FHM (Opt)). Ratios 1:M and 1:N are indicated. + +(\*) Pending 3GPP work completion on W1 + +Figure 44: Scenario D, Including NSA + +# Annex (Informative): Change History + +| Date | Revision | Description | +|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2019.01.18 | V0000 | Template with initial scenarios. | +| 2019.01.29 | V00.00 | Updates to terminology, miscellaneous other updates | +| 2019.02.07 | V00.00 | More definitions in 2.1, New Sec 4 on Overall Architecture, expansion/ updates of sec 5 Profiles, added Sec 6 OAM placeholder. | +| 2019.03.18 | V00.00 | Many additions in content and section structure. | +| 2019.04.01 | V00.00 | Some restructuring and combining of early sections, and more discussion on scope and context. Addition of implementation consideration section, including performance. Added optional Fronthaul GW. Provided framework discussion in each scenario's subsection. Other updates. | + +| | | | +|------------|--------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2019.04.10 | V00.00 | Updates to include comments before April 11 review. Comments from RaviKanth (Aricent), Pasi (Red Hat), Shinobu (KDDI), and Lyndon (Ciena). | +| 2019.04.15 | V00.00 | Updates to include some updates from comments from April 11 review. | +| 2019.04.24 | V00.00 | Updates of diagrams to address comments, additional figures on scope, and other changes to address April 11 review comments. | +| 2019.05.01 | V00.00 | Updates to diagrams for Scenarios A and B. Modifications per KDDI regarding C.2. | +| 2019.05.12 | V00.00 | Updates based on meeting discussions, subsection additions based on proposals. | +| 2019.05.15 | V00.00 | Clean-up in preparation of creating a baseline document – marking of many comments as done, adding editor notes where needed, and other clarifications. | +| 2019.05.20 | V00.00 | Continued clean-up in preparation of a baseline. | +| 2019.05.29 | V00.00 | Continued clean-up in preparation of a baseline. | +| 2019.06.04 | V00.00 | Major additions to the Cloud requirements in section 5.4 and Appendix B by Wind River, plus updates to the Fronthaul section from China Mobile. Various additional minor updates. | +| 2019.06.13 | V00.01 | This is the same as V00.00.13, but with renumbering to indicate this is the initial baseline for comment, V00.01.00 | +| 2019.06.14 | V00.01 | This includes updates from CRs discussed and agreed to on the June 13 call: <ul style="list-style-type: none"> <li>• Wind River contributions on adding a figure for NUMA illustration and a major enhancement of Sec 9.1 on cache</li> <li>• AT&T contribution to add material on centralization of O-DU/O-CU resources, to Sections 5.1 and 6.2</li> <li>• Update of figures to address Open Fronthaul comments (discussed June 6)</li> </ul> | +| 2019.07.05 | V00.01 | Updates to address several CRs: <ul style="list-style-type: none"> <li>• Multiple editorial items: <ul style="list-style-type: none"> <li>○ Draft text to address 5G/4G scope in Sec 1.2 – further discussion via separate CR</li> <li>○ Statement in 5.2 about performance to focus on delay</li> <li>○ Statement in 5.7 about transport</li> <li>○ 5.8; update of Figure 13 to indicate cloud locations. Added MEC text that to address MEC comment during call.</li> <li>○ Delay and loss table updates in 6, and statement in 5.2</li> </ul> </li> <li>• Former 9.1 and 9.3 sections of Appendix B (on cache and storage details) will be transferred to Tong’s document (Reference Design).</li> <li>• Update the O-DU pooling analysis in Section 5.1.3.</li> </ul> | +| 2019.07.18 | V00.01 | Updates to address multiple CRs, through July 18: <ul style="list-style-type: none"> <li>• Address NSA aspects in scope</li> <li>• Addition of 5.3 (Acceleration)</li> <li>• Removal of Scale up/down appendix, and note for future study</li> <li>• Update of delay figure in 5.2.</li> <li>• Update of Figure 4</li> </ul> | + +| | | | +|------------|--------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | <ul style="list-style-type: none"> <li>Replacement of Zbox concept with O-Cloud, and all related updates.</li> </ul> | +| 2019.08.02 | V00.01 | <p>Updates to address multiple CRs, discussed on Aug 1:</p> <ul style="list-style-type: none"> <li>Update Section 5.6, merge in sec 7, explain some fundamental operations concepts.</li> <li>Update the sync section to point to work in other WGs, and say that text will wait until CAD version 2.</li> <li>Update the delay section (5.2.1)</li> <li>Remove notes that refer to items that will not receive contributions in version 1. Remove comments that are no longer relevant.</li> <li>Remove Appendix A</li> </ul> | +| 2019.08.09 | V00.01 | <p>Updates to address multiple CRs and DT review comments, discussed on Aug 8.</p> <ul style="list-style-type: none"> <li>Update 5.2.1 to address non-optimal fronthaul, and to correct some equations</li> <li>Update 5.6 to add a figure showing the O1* interface</li> <li>Addressed a range of comments by DT, some editorial, some more involved.</li> </ul> | +| 2019.08.16 | V00.01 | <p>Updates to address multiple CRs and DT review comments, discussed on Aug 15.</p> <ul style="list-style-type: none"> <li>Updates to address Ericsson's comments</li> <li>Update to address DT's request to define vO-DU tile</li> <li>Update of the Cloud Considerations section (5.4), mostly for restructuring to remove duplication, but to also add material for VMs or Containers where necessary to provide balanced coverage.</li> <li>Additional updates: Many resolved and obsolete Word comments have been removed in anticipation of finalization.</li> <li>References to documents that are not finalized have been removed.</li> </ul> | +| 2019.08.23 | V00.01 | <p>Updates to reflect:</p> <ul style="list-style-type: none"> <li>Updates of the O-DU pooling section based on Aug 20 discussion</li> <li>Management section updates are to address comments made on Aug 15 discussion, particularly regarding the use of the term domain manager and its role in an ME, and the location of O1 terminations</li> <li>Edits to remove references to O-RAN WGs, and make updates of the revision history.</li> <li>Addition of standard O-RAN Annex <i>ZZZ</i></li> </ul> | +| 2019.08.26 | V00.01 | <ul style="list-style-type: none"> <li>Clean up of references and cross references to them</li> <li>Removed Word comments</li> <li>Removed cardinality questions in Scenarios A (removed 6.1.1) and Scenario B</li> </ul> | +| 2019.08.26 | V00.01 | Final minor comments during Aug 27 WG6 call, in preparation for vote. | +| 2019.10.01 | V01.00 | Update of Annex <i>ZZZ</i> , page footers, and addition of title page disclaimer. | +| 2020.01.17 | V01.00 | <p>Merged the following CRs, but with</p> <ul style="list-style-type: none"> <li>ATT-2019-11-19 CADS-C CR ATT-CAD-010 acceleration 01.00.00</li> <li>WRS 2019-12-04 CAD-C 01.00.00 rev 1</li> </ul> | +| 2020.02.09 | V01.00 | <p>Simplified 5.6.</p> <ul style="list-style-type: none"> <li>Removed 5.6.1, 5.6.2 – replaced it with pointers to O1, and O2 specification.</li> <li>Incorporated NVD comments on 5.3 and 5.4 addressing inline acceleration as an option</li> </ul> | + +| | | | +|------------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2020.03.03 | V01.00 | <ul style="list-style-type: none"> <li>Updated 4, 4.1 to reflect the latest O-RAN architecture</li> <li>Incorporated comments on 5.6 to include O1, O2 references.</li> <li>Updated 4.3 with O-Cloud description and definitions of key components of O-Cloud</li> <li>Updated 5.3, Figure 15 to reflect O-Cloud reference figure in 4.3</li> </ul> | +| 2020.03.09 | V01.00 | <ul style="list-style-type: none"> <li>Various minor editorial modifications, take them as suggestions for better readability...</li> </ul> | +| 2020.03.10 | V01.05 | <ul style="list-style-type: none"> <li>Incorporated Ericsson comments provided on v01.00.02</li> <li>Updated 1.1 to include O-RAN Architecture description</li> <li>Added definitions for O-RAN Physical NF, O-RAN Cloudified NF</li> </ul> | +| 2020.03.14 | V01.06 | Minor editorial modifications, make this version ready for WG6 internal review and voting | +| 2020.03.20 | V02.00 | Minor editorial, make this version ready for TSC review and voting | +| 2020.07.04 | V02.01 | Incorporated the following CRs: <ul style="list-style-type: none"> <li>TIM.AO-2020.05.18-WG6-CR-0001-CADS Scenario B Extension-v05</li> <li>WRS-2020-04-24 CAD-v02.00 CR for PTP Notifications v05</li> </ul> | +| 2020.07.06 | V02.01 | Added architecture of O-Cloud Resource Pool | +| 2020.07.14 | V02.01 | Addressed minor editorial comments received, making it ready for TSC review and voting | +| 2021.07.01 | V02.02 | Incorporated the following CRS: <ul style="list-style-type: none"> <li>DIS-2020-08-03 CAD-v02.01 CR for OMAC v02</li> <li>WRS-2020-09-15 CAD 2.01 CR for LLS-C1 Time Sync Requirements</li> <li>JNPR-2021.05.13-WG6-CR-0001-VLAN_Based_Networking-v04</li> </ul> Editorial changes: <ul style="list-style-type: none"> <li>Rename references to O-vDU as vO-DU</li> </ul> | +| 2021.07.15 | V02.02 | Fixed broken reference for O-RAN WG4, <i>Control, User and Synchronization Plane Specification</i> . | +| 2022.03.31 | V03.00 | Merged three CRs <ol style="list-style-type: none"> <li><a href="#">Clarification about synchronization requirements of CAD scenarios</a></li> <li><a href="#">O-Cloud Gateway</a></li> <li><a href="#">Terminology Update</a></li> </ol> | +| 2022.03.31 | V03.01 | Corrections from comment wiki | +| 2022.04.05 | V3.02 | Merged CR<br><a href="#">O-Cloud API</a> | +| 2022.04.05 | V3.03 | Per discussion on approval call, removed version numbers for references to O-RAN's own documents. References are just to whatever the latest version is. | +| 2022.07.25 | V4.00 | Merged two CRs <ol style="list-style-type: none"> <li><a href="#">PTP Support over UDP</a></li> <li><a href="#">IMS Provisioning CADS Concepts update</a></li> </ol> | +| 2023.07.14 | V05.00.01 | Merged four CRs <ol style="list-style-type: none"> <li>Tiered Clouds Clarification</li> <li>Change "Core Cloud" to "Central Cloud"</li> <li>Terminology Alignment</li> <li>Clarification of SMO and O-Cloud responsibilities</li> </ol> | + +| | | | +|------------|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.11.10 | V05.00.02 | Merged one CR<br>1. <b>Networking concepts related updates to CADS</b><br>Accepted Microsoft Word grammar recommendations on use or non-use of commas, semicolons and hyphens where the appeared to be correct | +| 2024.03.18 | V6.00.01 | Merged one CR<br>1. CADS O-Cloud capabilities definition | +| 2024.07.01 | V08.00 | Merged one CR<br>1. O-Cloud Networking Terminology Alignment<br>2. Clarification of descriptions of Fronthaul Gateway and Fronthaul Multiplexer | +| 2024.11.20 | V08.01 | Merged one CR<br>1. Clarify the network to which O-Cloud connects | + +1788 \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/0a3bf12c1b08fb38ec08defa1396c702_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/0a3bf12c1b08fb38ec08defa1396c702_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e6dcc9e302a856c82eea3e0f42b96991a5f86437 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/0a3bf12c1b08fb38ec08defa1396c702_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8dd9f8ac666b42f15c7bbabf46cb027b3482c0ff21c69853d671eff51d92d840 +size 2838 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/0dceac7ad7a2cd2da9041029fbc837c8_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/0dceac7ad7a2cd2da9041029fbc837c8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..84b8a8647d87203d0faf27c7537c385b510b8cf8 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/0dceac7ad7a2cd2da9041029fbc837c8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1223eaabb146e7db07e6d14f2d462c9c824a35703f60654fffcb4b7f798ce544 +size 3053 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/13402216e42a494685023872d3283b2b_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/13402216e42a494685023872d3283b2b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..86182c869b3a3090d6e092290f7dc2d18391423f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/13402216e42a494685023872d3283b2b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9614bb9f4fc8f04d6b4c0c09115c220b49220d0f4dd1f7d279b2cc59326ae2be +size 3003 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/1a0256e0b93bf7d2f215af94406b7f5d_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/1a0256e0b93bf7d2f215af94406b7f5d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b8f02578b1238fdf27abbb3a04d768f4a307e900 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/1a0256e0b93bf7d2f215af94406b7f5d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c77f80efe65c98e5a16493f970f550f3a076d6a306df19d1cd5f2891d2896922 +size 33656 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/32028329f0bb7b4196c90d2d2cc0ec9d_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/32028329f0bb7b4196c90d2d2cc0ec9d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..62d985031f1fb79ab36aaad1d40fb551beeed75f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/32028329f0bb7b4196c90d2d2cc0ec9d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab04f2c5e5a99f0faa8c0b037971f3c47358e93555c06c819d8483a502604e99 +size 56982 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/43f58e5ee3ab79a0da81848da97c070a_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/43f58e5ee3ab79a0da81848da97c070a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e1bd8f7c0c40017f025e4a38b2654a2093879065 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/43f58e5ee3ab79a0da81848da97c070a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4e7cdea57e9639d1fa10596fb254c2add6c179073676fd5e4105cab35b416598 +size 57004 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/44144216bbb81b04271cd14894740be8_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/44144216bbb81b04271cd14894740be8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f584ddc61c87424edb82d890bbdd782515cbcf37 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/44144216bbb81b04271cd14894740be8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5ed9268b78d9f358ebe6967ed1fb04e3bf25411efb8ae41783e2ed0aa929f409 +size 32154 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/47542ea408142db34c7b4b3e4c12db3d_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/47542ea408142db34c7b4b3e4c12db3d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0e0cf82cde2cd93ab9618fae0dd836d118df160a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/47542ea408142db34c7b4b3e4c12db3d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c6125941bf09a90af7778ba2789af8d46cd7a944c57edbadcc9f2dc72c914fe +size 98183 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/4fef7d15e3675e214e3cb426f24e1dbd_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/4fef7d15e3675e214e3cb426f24e1dbd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..da44ccdb62576926e41defecd7b3a196bb2d8b09 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/4fef7d15e3675e214e3cb426f24e1dbd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cfa6d1576c53ac2df857a61781a0158aa1d8c54a193ef97fcb9eb32edd865a99 +size 49892 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/5b0474628924e91872b16d12889f1796_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/5b0474628924e91872b16d12889f1796_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..64c382cc5be775d00f7daf22a8eb6436390a92b9 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/5b0474628924e91872b16d12889f1796_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15e720eba4641686683e6edf5d258f46e1b7141f199fa569afa415e1117d7332 +size 3022 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/5ed86429e3855b6d5cd5d663081d9a00_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/5ed86429e3855b6d5cd5d663081d9a00_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d280631a31fd9f7aa475df884920e4d89397445 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/5ed86429e3855b6d5cd5d663081d9a00_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:19c500bb47024b40f869b1779ccffbae2c6dcdeee993f6527d9acac21c399e65 +size 55982 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/633a25fb7963a57a9ca93c98dd3e0543_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/633a25fb7963a57a9ca93c98dd3e0543_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..28bb39f900143c3c5020505c3ebf2a2fc411bc7d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/633a25fb7963a57a9ca93c98dd3e0543_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:de5fcb29c6d0578dd2a2e5681ce20265b7bc1f2660b632dbd502074b6c905bcb +size 16271 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/6444cfc61ebec29ffc27dcb692576aa8_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/6444cfc61ebec29ffc27dcb692576aa8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e4889a718ba245046594f691d8d07a39c9a8b143 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/6444cfc61ebec29ffc27dcb692576aa8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9d11723a4f6d2de3e860106bd2be954dca98c79f224417dff218e45ae70d7dec +size 15674 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/6e2b107403af1d019e386ce12d3592c1_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/6e2b107403af1d019e386ce12d3592c1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8811037cbd9644df698f0aa6e8d274a13258e64e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/6e2b107403af1d019e386ce12d3592c1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ed263410b2933a5b3e1b4750b42746c7cfa3ab538df0b675267b1d15c190e2d +size 3001 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/72c0f5b2f375051074a59e709c800210_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/72c0f5b2f375051074a59e709c800210_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3e0bba06299f8f8d1f02154139f64b6033aef217 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/72c0f5b2f375051074a59e709c800210_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0ea0b79d92dae5b916fee533c11782c99326001cc0e1c933f94cd4de0a2b332b +size 61437 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/72c5fd07a7384f5657dbe8ac94a45164_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/72c5fd07a7384f5657dbe8ac94a45164_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eb9396101a2ff4578d4c39c7c34210d35fa50f55 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/72c5fd07a7384f5657dbe8ac94a45164_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:96c4518aaf8a11bcec69b6560f6c229bb095c075641f4dd6747c177420486407 +size 145955 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/82d69ae939339ce20f870169f9841286_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/82d69ae939339ce20f870169f9841286_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e44094d3bd9ae254ae08c278d85907309b1158b5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/82d69ae939339ce20f870169f9841286_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3526050991466e855a0ee37ccb078ed5a0e002c183a1133f80ebd19785c8432f +size 2840 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/856ef3f5c62ae95f4b32c720eae2b6c2_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/856ef3f5c62ae95f4b32c720eae2b6c2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a1a714a688d1411344abfd3d12d68e875541d4df --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/856ef3f5c62ae95f4b32c720eae2b6c2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6706580670599cae4ff1cb287d2bc9456272a7e5ee498f80c061fe0204257b51 +size 3014 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/8b1755f427f4aaa57bcdf4dea68b06b3_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/8b1755f427f4aaa57bcdf4dea68b06b3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f49177b8cf80455a5fe119703c2a5da13c005138 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/8b1755f427f4aaa57bcdf4dea68b06b3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e89abd73ee9c007e8b26e6eb468c31702e817307c74fd492b5b6c3fa66726614 +size 59500 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/8dcf1887868849cde56b4d9c15a23a61_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/8dcf1887868849cde56b4d9c15a23a61_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f62f56faa7486f29a58d226a026fe6579e93efcb --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/8dcf1887868849cde56b4d9c15a23a61_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:21a02ee878d50ad3e6e91e9d11ae8c995791f164af99c62f7940c2e2c409fb10 +size 96407 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/9f9fcda2a7844565205dd9b5aeb02cf5_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/9f9fcda2a7844565205dd9b5aeb02cf5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db94c22c2e85adf103f2546daf4945160095a4ac --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/9f9fcda2a7844565205dd9b5aeb02cf5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:31a2fc905b0e00174d16371b905499c18ad275d39c087d69ee5ac9fe807fedda +size 2888 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/a28719d471c29f6166dbb0aca4ad7277_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/a28719d471c29f6166dbb0aca4ad7277_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d3b66717e7685a7c5e2a29bcadfa5e6c61455043 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/a28719d471c29f6166dbb0aca4ad7277_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e71dae597b45d59f7db823dc0a3210793a8fc7db2e1f924f3e78c041c9720b72 +size 34344 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/a6746db86d607328af2c7c610e533993_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/a6746db86d607328af2c7c610e533993_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c5400ad849fecca424f0f871b82b0e5376ac7430 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/a6746db86d607328af2c7c610e533993_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:550c844228f2d8394cf014c23bb31c98695edcf418112fb809fa8c28e6720ff8 +size 3898 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/af1b1bc7b01ec9989422081652b7c67c_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/af1b1bc7b01ec9989422081652b7c67c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2f3e687169497cc33ede6bb91ee070a1bea7b5a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/af1b1bc7b01ec9989422081652b7c67c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8c72508a5fdd1b7a55b9bb8c48cca4550f1c1b73680131fa229c77a5b5dc1763 +size 36362 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/b44f56cde085a91c6b70638807ceb9e4_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/b44f56cde085a91c6b70638807ceb9e4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..32b7a637cee95b41a9f1cc23a8eed4b0051b6be6 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/b44f56cde085a91c6b70638807ceb9e4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1dcec0cd2645f27e6290d907e23066b7a8e34c6745b0ef615aaf10e3f7437d4c +size 48539 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/cdc1ac4587b97878a1b1f851c6855cde_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/cdc1ac4587b97878a1b1f851c6855cde_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cf9a5a031f25bc563a5d7707f73a1086b201b2e5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/cdc1ac4587b97878a1b1f851c6855cde_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:519231afa7cb57c796a8cd48a5c5fa872b8537a81745085ac805aff38c188550 +size 3054 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/d32b0e4fdd011862fa39de6668a68c8b_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/d32b0e4fdd011862fa39de6668a68c8b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d8f532a4b39f850bdbaefa490d660d55b8338115 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/d32b0e4fdd011862fa39de6668a68c8b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6cdbc29beea244dd336f62f26e5ce519926c65659f966cbc9ed201344b7df64e +size 55030 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/d9c4a96b38c95923e089e6ad355c6eed_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/d9c4a96b38c95923e089e6ad355c6eed_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7a0ecfd9a6441be98ab5fa16c5e3f24b55cc77e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/d9c4a96b38c95923e089e6ad355c6eed_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:eca6750bf0b6c9f83752a8ee13339a07184a16dd188d43a7bf7b5e52dc66e791 +size 36892 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/e6937abfd5bc1d1ac4eeaf9c5200a237_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/e6937abfd5bc1d1ac4eeaf9c5200a237_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e84aaefda0d067056bb6131b64fd42e4c649178c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/e6937abfd5bc1d1ac4eeaf9c5200a237_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7aae67382e4621dbc8be5c49f95bfec1149b52802eb32d557aee76c50b92861 +size 63513 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/e94cbad3fc94494831c157c493684f5b_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/e94cbad3fc94494831c157c493684f5b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ed98c206cac3266a676a16db9067a2c376ec7bc6 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/e94cbad3fc94494831c157c493684f5b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6f02f8efaad72ca82f6fdc3163de317b41f6418a6f6587758adf82e8127c677b +size 43766 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/ee3f9deb5400694f99d7c4a4fe297104_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/ee3f9deb5400694f99d7c4a4fe297104_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ae348a4aecd32177d9a838e43d68cce17812be78 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/ee3f9deb5400694f99d7c4a4fe297104_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a611dcb0a88931f576dbd223d8dacb6211e8de63d695d64147f2b01a37b49137 +size 48398 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/f01ec052e07c217c5cb59e54f91bc0df_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/f01ec052e07c217c5cb59e54f91bc0df_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9f3e51d3e703cdb460fae3f34a20c00704a3f610 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/f01ec052e07c217c5cb59e54f91bc0df_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:14b73d605167a398550672c8c7ae47610c5b7133a6e9e354ad493230399e204b +size 54162 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/fcb6f62dacc8ca0774a7d155893c4717_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/fcb6f62dacc8ca0774a7d155893c4717_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9bb031127c9b8acfeac137aa539c8387c7a55651 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/fcb6f62dacc8ca0774a7d155893c4717_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:482256d210036509d754b739dee6c60661351ed276859483e6c4a6ff55ff7179 +size 31205 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/fe8378a4dd8dd937c1a943678a5a2782_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/fe8378a4dd8dd937c1a943678a5a2782_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..972860078fb5620d1ef70bc454d3d0f3ca09a676 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/fe8378a4dd8dd937c1a943678a5a2782_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a4fa8ac8e680b5349b81910c90626c633da1ec3841be305e4e79459f4b5538f +size 15837 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/fee7ed92c6fce1fbec6037ec5d432470_img.jpg b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/fee7ed92c6fce1fbec6037ec5d432470_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2ec41fb731d9a4fadc4d370570d1e73763b3aead --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/fee7ed92c6fce1fbec6037ec5d432470_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:723c159682214ba2635a256071764ce4201b1f7b127797d1a81e8c9362b82749 +size 3967 diff --git a/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/raw.md b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..dafde4e163c53487489bcd63dc6125d210889774 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.CLOUD-REF-v02.00/raw.md @@ -0,0 +1,1421 @@ + + +# Cloud Platform Reference Designs --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# Cloud Platform Reference Designs --- + +Copyright © 2021 by O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in the Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +# Revision History + +| Date | Revision | Author | Description | +|------------|--------------------|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2019.06.02 | 01.00.00 | Tong Li (Lenovo) | Initial skeleton. | +| 2019.08.05 | 01.00.01 | Tong Li (Lenovo) | Initial content with contributions from Intel, Lenovo, Mavenir, and Wind River. | +| 2019.11.05 | 01.00.03 | Guy Turgeon (Wind River) | Initial Cloud Platform Requirements | +| 2019.11.05 | 01.00.04 | Guy Turgeon (Wind River) | Cloud platform requirements additions | +| 2019.11.05 | 01.00.05 | Arjun Nanjundappa (Mavenir) | vBBU initial requirements | +| 2019.11.06 | 01.00.06 | Guy Turgeon (Wind River) | Cloud Platform Requirements architecture diagrams modifications and text | +| 2019.11.08 | 01.00.07 | Arjun Nanjundappa (Mavenir) | vBBU Stack Requirements updated Sections 3.3.8 (RAN Nodes Traffic Types and Acceleration) and 3.3.9 (Cloud Transport Protocol). | +| 2019.11.08 | 01.00.08 | Guy Turgeon (Wind River) | Merge 01.00.06 and 01.00.007 | +| 2019.11.14 | 01.00.09 | Guy Turgeon (Wind River) | Genericize Cloud Platform Requirements | +| 2019.11.18 | 01.00.10 | Guy Turgeon (Wind River) | Update Scenario B: high-level diagram with LLS-C3 and SMO. Modify Chapter 4 VM and Container based platform diagrams | +| 2019.11.26 | 01.00.11 | Arjun Nanjundappa (Mavenir) | 1. Made the Traffic Types Generic as AAL instead of BBDEV.2. Included different types of Acceleration: Look-aside, In-line and Hybrid-Mode Acceleration.3. Replaced S1-MME by S1-AP4. Updated CU-UP with S1-U and NG-U traffic type. | +| 2019.12.30 | 01.00.12 | Tong Li (Lenovo) | Re-structure doc, merge vendor & operator survey results, merge INT-004 rev 1 from Niall Power (Intel), and various edits | +| 2020.01.15 | 01.00.13 | Guy Turgeon (Wind River) | Specify CR-IO 4.2.2, add Wireless cipher 4.2.3, clean up Kubernetes architecture components figure in 5.2.3 | +| 2020.01.24 | 01.00.14 | Niall Power (Intel) | Specify AAL Requirements for the Hardware Acceleration section | +| 2020.01.29 | 01.00.14 (bis) | Arjun Nanjundappa (Mavenir) | Added content for Time Synchronization section and re-worked sections on Acceleration to capture different acceleration needs (i.e., traffic and algos) | +| 2020.01.31 | Baseline 01.00.01 | Lucian Suci (Orange) | Integrated contributions from Intel and Mavenir, implemented agreed resolutions for several comments received from RH, ERI, NVD (a few are still open...), generated the Baseline document | +| 2020.02.12 | Baseline 01.00.02 | Tong Li (Lenovo) | Revision based on WG6 group discussion and various edits | +| 2020.02.12 | Baseline 01.00.03 | Arjun Nanjundappa (Mavenir) | Time Synchronization Requirements and Figure Caption update | +| 2020.02.26 | Baseline-v01.00.05 | Lopamudra Kundu (Nvidia) | Revised section 4.3.2, appended lookaside and in-line acceleration dataflows and associated Fig. in section 4.3.1, added/revised figs. in section 5.1.6.2 related to GPU based inline PHY acceleration reference design and | + +| | | | | +|------------|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------| +| | | | high-level edge cloud platform for inline acceleration, provided additional Kubernetes plugins in section 5.2.3. | +| 2020.03.04 | Baseline-v01.00.07 | Arjun Nanjundappa (Mavenir) | Included both In-line and Look-aside acceleration diagrams for O-DU and Accelerators to other nodes have been kept generic for section 4.3.2. | +| 2020.03.12 | Baseline-v01.00.11 | Marge Hillis (Nokia), Lopamudra Kundu (Nvidia), Tong Li (Lenovo), Arjun Nanjundappa (Mavenir), Niall Power (Intel), Lucian Suci (Orange), Guy Turgeon (Wind River), Xiaogang Yan (China Mobile), Tao Yang (China Telecom) | Various edits. | +| 2020.03.17 | V00.16 | Lenovo, Red Hat, Orange | Time Sync modifications, minor editorial, make this version ready for WG6 internal review and voting | +| 2020.03.19 | V00.17 | Nokia, Red Hat | Time Sync section modifications proposal from Nokia (mostly editorial), and clarifications from Red Hat. | +| 2020.03.20 | V01.00 | | Version ready for TSC review and voting | +| 2020.07.10 | V01.01 | Udi Schwager (Wind River) | Added support for container.d | +| 2020.07.10 | V01.01 | Niall Power (Intel) | Added reference accelerator cards for acceleration | +| 2020.07.10 | V01.01 | Lopamudra Kundu (Nvidia) | Added reference design for edge cloud server with GPU based acceleration | +| 2020.09.01 | V01.01.01 | KDDI | Initial version applied changes to some text and figures | +| 2020.09.30 | V01.01.01 | Lucian Suci (Orange) | Merged KDDI version with latest Cloud Ref. Design spec, also handled the comments received from Ericsson, CMCC and Nvidia | +| 2020.10.21 | V01.01.01 | Lucian Suci (Orange) | Incorporated the CR on Time Sync, and the input from CTC, KDDI, Dell | +| 2020.11.05 | V02.00 | | Version ready for WG6 internal review and voting | + +# Table of Contents + +| | | +|--------------------------------------------------------------------|----| +| Table of Figures..... | 5 | +| Table of Tables ..... | 5 | +| Chapter 1 Introductory Material ..... | 6 | +| 1.1 Scope ..... | 6 | +| 1.2 References ..... | 6 | +| 1.3 Abbreviations..... | 7 | +| Chapter 2 Deployment Scenarios ..... | 9 | +| 2.1 Scenario B..... | 9 | +| 2.2 Scenario C..... | 10 | +| 2.2.1 Scenario C.1..... | 10 | +| 2.2.2 Scenario C.2..... | 11 | +| Chapter 3 Operator Requirements ..... | 12 | +| 3.1 Typical Use Cases..... | 12 | +| 3.2 Cloud Deployment Requirements..... | 14 | +| 3.2.1 Regional Cloud ..... | 14 | +| 3.2.2 Edge Cloud ..... | 14 | +| Chapter 4 O-Cloud Requirements..... | 15 | +| 4.1 O-Cloud Architectural Components and Requirements ..... | 15 | +| 4.1.1 Hardware Requirements ..... | 16 | +| 4.1.2 Operating System Requirements..... | 16 | +| 4.1.3 Cloud Platform Runtime Requirements ..... | 16 | +| 4.1.4 Generic Requirements for Cloud Platform Management..... | 17 | +| 4.1.5 VM/Container Management and Orchestration Requirements ..... | 18 | +| 4.2 Time Synchronization Requirements..... | 18 | +| 4.2.1 G.8275.1 Full Timing Support (FTS) ..... | 18 | +| 4.2.2 G.8275.2 Partial Timing Support (PTS) ..... | 20 | +| 4.3 Hardware Acceleration Requirements ..... | 20 | +| 4.3.1 Background on Acceleration Types..... | 20 | +| 4.3.2 Hardware Acceleration Abstraction Layer Requirements ..... | 23 | +| Chapter 5 (Informative) Cloud Platform Design Example ..... | 26 | +| 5.1 Cloud Platform Hardware Design Example..... | 26 | +| 5.1.1 Regional Cloud Server Example..... | 26 | +| 5.1.2 Edge Cloud Server Example..... | 27 | +| 5.1.3 BIOS/UEFI Configurations ..... | 28 | +| 5.1.4 Firmware Versions..... | 30 | +| 5.1.5 Accelerator Hardware ..... | 30 | +| 5.2 Cloud Platform Software Reference Design ..... | 33 | +| 5.2.1 Common Reference Configurations for all Profiles..... | 34 | +| 5.2.2 Regional Cloud Reference Configuration Profile ..... | 35 | +| 5.2.3 Edge Cloud Reference Configuration Profile ..... | 35 | +| 5.2.4 Example Real-time Linux Configurations ..... | 37 | +| 5.3 Time Synchronization Reference Design ..... | 38 | +| Annex ZZZ: O-RAN Adopter License Agreement..... | 40 | +| Section 1: DEFINITIONS ..... | 40 | +| Section 2: COPYRIGHT LICENSE ..... | 40 | +| Section 3: FRAND LICENSE ..... | 40 | +| Section 4: TERM AND TERMINATION ..... | 41 | +| Section 5: CONFIDENTIALITY ..... | 41 | +| Section 6: INDEMNIFICATION ..... | 41 | +| Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 42 | +| Section 8: ASSIGNMENT ..... | 42 | +| Section 9: THIRD-PARTY BENEFICIARY RIGHTS ..... | 42 | +| Section 10: BINDING ON AFFILIATES ..... | 42 | +| Section 11: GENERAL..... | 42 | + +# Table of Figures + +| | | +|------------------------------------------------------------------------------------------------------------------|----| +| Figure 2-1. Cloud deployment scenario B. .... | 9 | +| Figure 2-2. Scenario B – O-Cloud high-level deployment diagram. .... | 9 | +| Figure 2-3. Cloud deployment scenario C. .... | 10 | +| Figure 2-4. Scenario C – O-Cloud high-level deployment diagram. .... | 10 | +| Figure 2-5. Treatment of Network Slice: MEC for URLLC at Edge Cloud, Centralized Control, Single vO-DUs ..... 11 | 11 | +| Figure 2-6. Cloud deployment scenario C.1. .... | 11 | +| Figure 2-7. Treatment of Network Slice: MEC for URLLC at Edge Cloud, Separate vO-DUs..... | 12 | +| Figure 2-8. Cloud deployment scenario C.2. .... | 12 | +| Figure 4-1. Architecture component requirements for the cloud platform. .... | 15 | +| Figure 4-2. Key LLS-C3 Fronthaul Synchronization in an example implementation in O-Cloud. .... | 19 | +| Figure 4-3. O-DU interface and algorithm acceleration. .... | 21 | +| Figure 4-4. O-CU-CP interface and algorithm acceleration. .... | 22 | +| Figure 4-5. O-CU-UP interface and algorithm acceleration. .... | 23 | +| Figure 4-6. AAL support for multiple devices..... | 24 | +| Figure 4-7. AAL look-aside acceleration model..... | 24 | +| Figure 4-8. AAL inline acceleration model. .... | 25 | +| Figure 4-9. Dataflow paths in look-aside and inline acceleration architectures. .... | 26 | +| Figure 5-1. Hardware-accelerated FEC functions with look-aside model. .... | 31 | +| Figure 5-2. Hardware-accelerated front-end functions with inline model. .... | 31 | +| Figure 5-3. Hardware-accelerated end-to-end high-PHY functions with inline model. .... | 32 | +| Figure 5-4. Cloud platform for look-aside acceleration of O-DU and O-CU. .... | 32 | +| Figure 5-5. Cloud platform for O-DU inline acceleration and O-CU look-aside acceleration. .... | 33 | +| Figure 5-6. Cloud platform for O-DU inline acceleration of end-to-end high-PHY..... | 33 | +| Figure 5-7. Key synchronization chain elements in an example implementation in O-Cloud for LLS-C3. .... | 38 | + +# Table of Tables + +| | | +|--------------------------------------------------------------------------------------------|----| +| Table 2-1. Cardinality and Delay Performance for Scenario C.1 ..... | 11 | +| Table 3-1. AT&T Carrier aggregation requirements. .... | 12 | +| Table 3-2. Deutsche Telekom carrier aggregation requirements. .... | 13 | +| Table 3-3. Orange carrier aggregation requirements. .... | 13 | +| Table 3-4. KDDI carrier aggregation requirements. .... | 13 | +| Table 3-5. CMCC carrier aggregation requirements..... | 13 | +| Table 3-6. CTC carrier aggregation requirements. .... | 13 | +| Table 3-7. BBU pooling requirements..... | 14 | +| Table 3-8. Edge cloud environmental characteristics. .... | 15 | +| Table 4-1. Requirements for the cloud platform hardware. .... | 16 | +| Table 4-2. Requirements for the cloud platform operating system. .... | 16 | +| Table 4-3. Requirements for the cloud platform runtime. .... | 17 | +| Table 4-4. Cloud platform management requirements. .... | 18 | +| Table 4-5. Requirements for VM/container management and orchestration. .... | 18 | +| Table 4-6. O-DU acceleration types. .... | 21 | +| Table 4-7. O-CU-CP acceleration types. .... | 22 | +| Table 4-8. O-CU-UP acceleration types. .... | 23 | +| Table 5-1. Regional cloud server example design. .... | 27 | +| Table 5-2. Edge cloud server example design with FPGA acceleration. .... | 27 | +| Table 5-3. Edge cloud server example design with GPU acceleration. .... | 28 | +| Table 5-4. BIOS configurations for strong real-time systems. .... | 30 | +| Table 5-5. Firmware for example reference design based on Intel server board S2600WF. .... | 30 | +| Table 5-6. Common cloud platform reference configurations for all profiles. .... | 35 | +| Table 5-7. Regional cloud reference configuration profile. .... | 35 | +| Table 5-8 Edge Cloud Reference Configuration Profile..... | 37 | +| Table 5-9. Real-time Linux configurations..... | 38 | + +# Chapter 1 Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN ALLIANCE. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN ALLIANCE modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). + +y the second digit is incremented when editorial only changes have been incorporated in the document. + +z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +The present document focuses on cloud deployment scenario B and C (including C.1 and C.2), as defined in the O-RAN WG6 Cloud Architecture document [1], and specifies requirements and reference designs for the cloud platform hardware and software. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of this specification. + +[1] O-RAN WG6, Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN. + +[2] O-RAN WG4, Control, User and Synchronization Plane Specification. + +[3] GR-63-CORE for Network Switching Systems (NEBS) Seismic Rated Enclosures, Telcordia. + +[4] GR-1089-CORE Electromagnetic Compatibility and Electrical Safety, Telcordia. + +[5] OTII Server Technical Specification, 2019. + +[6] OCP openEDGE Project, <https://www.opencompute.org/wiki/Telcos/openEDGE>. + +[7] ETSI EN300 019-1-3 Class 3.2 Equipment Engineering (EE) Environmental Conditions and Environmental Tests for Telecommunications Equipment Part 1-3: Classification of Environmental Conditions Stationary Use at Weather-protected Locations. + +[8] ETSI EN300386 (v1.6.1) Terrestrial Trunked Radio (TETRA); Direct Mode Operation (DMO); Part 6: Security + +[9] FCC CFR47 15 (class A), FCC, Rules and Regulations for Title 47 Telecommunications. + +[10] CISPR 22/32 (Class A) International Electrotechnical Commission (IEC) International Special Committee on Radio Interference, Radiated Emission Limits. + +[11] CISPR 24, IEC Information Technology Equipment – Immunity Characteristics. + +[12] TEC/EMI/TEL-001/01/FEB-09 – Information Technology Equipment. + +[13] TEC/IR/SWN-2MB/07/MAR-10 – Information Technology Equipment. + +[14] IEC 62368-1:2014, Safety Standard for Information Technology Equipment and Audio Video Equipment. + +[15] O-RAN WG4 Management Plane Specification. + +[16] 3GPP TS 23.501: “System architecture for the 5G System (5GS)”. + +[17] O-RAN WG8, Base Station O-DU and O-CU Software Architecture and APIs. + +[18] O-RAN Infrastructure Project, <https://wiki.o-ran-sc.org/display/IN/Infrastructure+Home>. + +## 1.3 Abbreviations + +For the purposes of the present document, the following abbreviations apply. + +| | | +|--------|-------------------------------------------------| +| AAL | Acceleration Abstraction Layer | +| API | Application Programming Interface | +| ASIC | Application-specific Integrated Circuit | +| BIOS | Basic Input Output System | +| BBU | Base Band Unit | +| CNF | Containerized Network Function | +| CPU | Central Processing Unit | +| DSP | Digital Signal Processing | +| FPGA | Field Programmable Gate Array | +| DPDK | Data Plane Development Kit | +| eNB | eNodeB (applies to LTE) | +| EPA | Enhanced Platform Awareness | +| FEC | Forward Error Correcting | +| FFS | For Further Study | +| FFT | Fast Fourier Transform | +| FHGW | Front-haul Gateway | +| FTS | Full Timing Support | +| gNB | gNodeB (applies to NR) | +| GNSS | Global Navigation Satellite System | +| GPU | Graphics Processing Unit | +| HA | High Availability | +| HW | Hardware | +| LLS-C3 | Lower Layer Split Configuration 3 | +| NFV | Network Functions Virtualization | +| NFVI | Network Functions Virtualization Infrastructure | +| NIC | Network Interface Card | +| NSA | Non-standalone | +| NUMA | Non-uniform Memory Access | +| O-CU | O-RAN Centralized Unit | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| OS | Operating System | +| PHC | PTP Hardware Clock | +| PIM | Physical Infrastructure Manager | +| PRACH | Physical Random Access Channel | +| PRTC | Primary Reference Time Clock | +| PSU | Power Supply Unit | +| PTP | Precision Time Protocol | + +| | | | +|-----|--------|---------------------------------------| +| 194 | PTS | Partial Timing Support | +| 195 | RAID | Redundant Array of Inexpensive Disks | +| 196 | RIC | RAN Intelligent Controller | +| 197 | RT | Real-time | +| 198 | SA | Standalone | +| 199 | SMO | Service Management and Orchestration | +| 200 | SR-IOV | Single Root I/O Virtualization | +| 201 | SW | Software | +| 202 | T-BC | Telecom Boundary Clock | +| 203 | T-GM | Telecom Grand Master | +| 204 | T-TSC | Telecom Time Slave Clock | +| 205 | UEFI | Unified Extensible Firmware Interface | +| 206 | vBBU | Virtual Baseband Unit | +| 207 | VF | Virtual Function | +| 208 | VIM | Virtualized Infrastructure Manager | +| 209 | VM | Virtual Machine | +| 210 | VNF | Virtualized Network Function | +| 211 | | | + +# Chapter 2 Deployment Scenarios + +This document focuses on cloud deployment scenarios B and C (including both variants C.1 and C.2), as defined in the O-RAN Cloud Architecture document [1]. The current version of this document focuses on SA NR gNBs deployed on the O-Cloud. The extensions of O-Cloud, if required, to support NSA scenarios indicated in the annexes of the O-RAN Cloud Architecture document [1] are FFS. + +O-Clouds are deployed at both regional and edge locations. At a given location, the edge O-Cloud can scale from a single server to a clustered configuration with possibly hundreds of servers. This version of the document focuses on a container-based cloud platform (see Ch.5.2 for a reference design example) and it will address VM-based designs in a future release. For the time synchronization aspects, this version of the document focuses on the LLS-C3 configuration [2], i.e., O-DU and O-RU are synchronized from the fronthaul network (see Ch.5.3 for a reference design example). + +The terms, vO-CU and vO-DU, represent virtualized or containerized O-CU and O-DU, and are used interchangeably with O-CU and O-DU in this document. The optional use of a Front-haul Gateway (FHGW) in the architecture allows significant savings in providing transport between the O-RU and O-DU functionalities. + +## 2.1 Scenario B + +Figure 2-1 illustrates scenario B, where the near-RT RIC is virtualized or containerized on a regional O-Cloud, and the O-CU and O-DU functions are virtualized or containerized on an edge O-Cloud that typically resides at a different location. + +The interface that the near-RT RIC uses between the regional O-Cloud and the edge O-Cloud is E2. Interfaces between the O-CU and O-DU managed functions are either within the same single managed element, or among multiple managed elements within the same edge O-Cloud. + +![Figure 2-1: Cloud deployment scenario B. This diagram shows the architecture across three main components: Regional cloud, Edge cloud, and Cell site. The Regional cloud contains a 'Near-RT RIC' and a 'Cloud Platform'. The Edge cloud contains 'vO-CU' and 'vO-DU' (connected via F1 interface) and a 'Cloud Platform'. The Cell site contains an 'O-RU (/RU)'. An optional 'GW (Opt)' is shown between the Edge cloud and the Cell site. Connections include: '1:L E2 E2' between Regional and Edge clouds; 'Open fronthaul' between Edge cloud and Cell site; and 'UPF, MEC' connected to the Regional cloud. Both clouds are labeled 'Open chassis and blade spec'.](1a0256e0b93bf7d2f215af94406b7f5d_img.jpg) + +Figure 2-1: Cloud deployment scenario B. This diagram shows the architecture across three main components: Regional cloud, Edge cloud, and Cell site. The Regional cloud contains a 'Near-RT RIC' and a 'Cloud Platform'. The Edge cloud contains 'vO-CU' and 'vO-DU' (connected via F1 interface) and a 'Cloud Platform'. The Cell site contains an 'O-RU (/RU)'. An optional 'GW (Opt)' is shown between the Edge cloud and the Cell site. Connections include: '1:L E2 E2' between Regional and Edge clouds; 'Open fronthaul' between Edge cloud and Cell site; and 'UPF, MEC' connected to the Regional cloud. Both clouds are labeled 'Open chassis and blade spec'. + +**Figure 2-1. Cloud deployment scenario B.** + +This scenario is to support deployments in locations with limited remote front-haul capacity and a set of O-RUs spread out in a limited area, supported by pooled vO-CU/vO-DU functionality while still meeting the O-DU latency requirements. The optional use of a Front-haul Gateway (FHGW) in the architecture allows significant savings in providing transport between the O-RU and vO-DU functionalities. + +Figure 2-2 shows the O-Cloud high-level deployment diagram. One vO-CU and one vO-DU together form a virtual BBU (vBBU), which connects to $N$ O-RUs (typically up to 64, see [1]). This deployment should support tens of thousands of O-RUs per near-RT RIC, and therefore $L$ could easily exceed 100. + +![Figure 2-2: Scenario B – O-Cloud high-level deployment diagram. This diagram shows the high-level deployment across three main components: Regional Cloud, Edge Cloud, and Cell site. The Regional Cloud contains a 'Containerized near-RT RIC' and a 'Virtualized near-RT RIC' on a 'Cloud Platform'. The Edge Cloud contains 'Containerized O-CU / O-DU' and 'Virtualized O-CU / O-DU' on a 'Cloud Platform'. The Cell site contains an 'O-RU (/RU)'. An optional 'GW (Opt)' is shown between the Edge cloud and the Cell site. Connections include: 'O2' between Regional and Edge clouds; '1:L' between Regional and Edge clouds; 'Open fronthaul' between Edge cloud and Cell site; and 'UPF, MEC' connected to the Regional cloud. The Edge cloud is also connected to a 'Network of Switches' which includes a 'PTC/T-GM' and a 'switch'. The Network of Switches is connected to the Cell site via 'PTP / SyncE Path' and 'Open fronthaul'.](fcb6f62dacc8ca0774a7d155893c4717_img.jpg) + +Figure 2-2: Scenario B – O-Cloud high-level deployment diagram. This diagram shows the high-level deployment across three main components: Regional Cloud, Edge Cloud, and Cell site. The Regional Cloud contains a 'Containerized near-RT RIC' and a 'Virtualized near-RT RIC' on a 'Cloud Platform'. The Edge Cloud contains 'Containerized O-CU / O-DU' and 'Virtualized O-CU / O-DU' on a 'Cloud Platform'. The Cell site contains an 'O-RU (/RU)'. An optional 'GW (Opt)' is shown between the Edge cloud and the Cell site. Connections include: 'O2' between Regional and Edge clouds; '1:L' between Regional and Edge clouds; 'Open fronthaul' between Edge cloud and Cell site; and 'UPF, MEC' connected to the Regional cloud. The Edge cloud is also connected to a 'Network of Switches' which includes a 'PTC/T-GM' and a 'switch'. The Network of Switches is connected to the Cell site via 'PTP / SyncE Path' and 'Open fronthaul'. + +**Figure 2-2. Scenario B – O-Cloud high-level deployment diagram.** + +## 2.2 Scenario C + +Figure 2-3 illustrates scenario C, where the near-RT RIC and the vO-CU functions are virtualized or containerized on a regional O-Cloud, and the O-DU function is virtualized or containerized on an edge O-Cloud that typically resides at a different location. + +The interfaces that the near-RT RIC and O-CU use between the regional O-Cloud and the edge O-Cloud are E2 and, respectively, F1 (i.e., F1-c and F1-u). Interfaces between the near-RT RIC and O-CU managed functions are either within the same single managed element, or among multiple managed elements within the same regional O-Cloud. + +![Figure 2-3: Cloud deployment scenario C. This diagram shows the architecture of Scenario C. On the left is the 'Regional cloud' containing a 'Near-RT RIC' and a 'vO-CU' on a 'Cloud Platform' (Open chassis and blade spec). A 'UPF, MEC' block is connected to the vO-CU. The Regional cloud connects to the 'Edge cloud' via an 'E2' interface (1:M) and 'F1-c & F1-u' interfaces. The Edge cloud contains a 'vO-DU' on a 'Cloud Platform' (Open chassis and blade spec). The Edge cloud connects to the 'Cell site' via an 'Open fronthaul' (1:N) interface, passing through a 'GW (Opt)' block. The Cell site contains an 'O-RU (/RU)' block.](af1b1bc7b01ec9989422081652b7c67c_img.jpg) + +Figure 2-3: Cloud deployment scenario C. This diagram shows the architecture of Scenario C. On the left is the 'Regional cloud' containing a 'Near-RT RIC' and a 'vO-CU' on a 'Cloud Platform' (Open chassis and blade spec). A 'UPF, MEC' block is connected to the vO-CU. The Regional cloud connects to the 'Edge cloud' via an 'E2' interface (1:M) and 'F1-c & F1-u' interfaces. The Edge cloud contains a 'vO-DU' on a 'Cloud Platform' (Open chassis and blade spec). The Edge cloud connects to the 'Cell site' via an 'Open fronthaul' (1:N) interface, passing through a 'GW (Opt)' block. The Cell site contains an 'O-RU (/RU)' block. + +**Figure 2-3. Cloud deployment scenario C.** + +This scenario is to support deployments in locations with limited remote front-haul capacity and a set of O-RUs spread out in a small area that restricts the number of O-RUs that can be pooled while still meeting the O-DU latency requirements. The O-CU function is further pooled to increase the efficiency of the hardware platform which it shares with the near-RT RIC function. + +Figure 2-4 shows the O-Cloud high-level deployment diagram. The edge O-Cloud is expected to connect to $N$ O-RUs (typically up to 64, see [1]). This deployment should support tens of thousands of O-RUs per near-RT RIC, and therefore $M$ could easily exceed 100. + +![Figure 2-4: Scenario C – O-Cloud high-level deployment diagram. This diagram shows the high-level deployment of the O-Cloud. It includes an 'SMO' block connected to a 'UPF, MEC' block. The 'Regional Cloud' contains an 'O-Cloud' with 'Containerized near-RT RIC / O-CU' and 'Virtualized near-RT RIC / O-CU' on a 'Cloud Platform'. The 'Edge Cloud' contains an 'O-Cloud' with 'Containerized O-DU' and 'Virtualized O-DU' on a 'Cloud Platform'. The Regional Cloud connects to the Edge Cloud via a '1:M' interface. The Edge Cloud connects to the 'Cell site' via an 'Open fronthaul' (1:N) interface, passing through a 'GW (Opt)' block. The Cell site contains an 'O-RU (/RU)' block. A 'Network of Switches' block is connected to the Edge Cloud and the Cell site, with 'PTP/SyncE Path' and 'Configuration LLS-C3 synchronization' labels.](44144216bbb81b04271cd14894740be8_img.jpg) + +Figure 2-4: Scenario C – O-Cloud high-level deployment diagram. This diagram shows the high-level deployment of the O-Cloud. It includes an 'SMO' block connected to a 'UPF, MEC' block. The 'Regional Cloud' contains an 'O-Cloud' with 'Containerized near-RT RIC / O-CU' and 'Virtualized near-RT RIC / O-CU' on a 'Cloud Platform'. The 'Edge Cloud' contains an 'O-Cloud' with 'Containerized O-DU' and 'Virtualized O-DU' on a 'Cloud Platform'. The Regional Cloud connects to the Edge Cloud via a '1:M' interface. The Edge Cloud connects to the 'Cell site' via an 'Open fronthaul' (1:N) interface, passing through a 'GW (Opt)' block. The Cell site contains an 'O-RU (/RU)' block. A 'Network of Switches' block is connected to the Edge Cloud and the Cell site, with 'PTP/SyncE Path' and 'Configuration LLS-C3 synchronization' labels. + +**Figure 2-4. Scenario C – O-Cloud high-level deployment diagram.** + +### 2.2.1 Scenario C.1 + +This is a variation of Scenario C, driven by the fact that different types of traffic (network slices) have different latency requirements. In particular, URLLC has more demanding user-plane latency requirements, and Figure 2-5 below shows how the vO-CU User Plane (vO-CU-UP) could be terminated in different places for different network slices. Below, network slice 3 is terminated in the edge O-Cloud. This scenario is also suitable in case there is not enough space or power supply to install all vO-CUs and vO-DUs in one edge O-Cloud. + +![Figure 2-5: Treatment of Network Slice: MEC for URLLC at Edge Cloud, Centralized Control, Single vO-DUs. The diagram shows a 1:M relationship between Regional Cloud and Edge Cloud, and a 1:N relationship between Edge Cloud and Cell site. The Regional Cloud contains vO-CU-CP1 and vO-CU-UP1. The Edge Cloud contains vO-CU-UP2 and vO-DU. The Cell site contains O-RU. Three network slices are shown: Slice1 (mMTC), Slice2 (eMBB), and Slice3 (URLLC). Slice3 is associated with MEC at the Edge Cloud. Arrows indicate data flow and control planes (E1, E2, F1-c, F1-u).](b44f56cde085a91c6b70638807ceb9e4_img.jpg) + +Figure 2-5: Treatment of Network Slice: MEC for URLLC at Edge Cloud, Centralized Control, Single vO-DUs. The diagram shows a 1:M relationship between Regional Cloud and Edge Cloud, and a 1:N relationship between Edge Cloud and Cell site. The Regional Cloud contains vO-CU-CP1 and vO-CU-UP1. The Edge Cloud contains vO-CU-UP2 and vO-DU. The Cell site contains O-RU. Three network slices are shown: Slice1 (mMTC), Slice2 (eMBB), and Slice3 (URLLC). Slice3 is associated with MEC at the Edge Cloud. Arrows indicate data flow and control planes (E1, E2, F1-c, F1-u). + +**Figure 2-5. Treatment of Network Slice: MEC for URLLC at Edge Cloud, Centralized Control, Single vO-DUs** + +In Scenario C.1, all O-CU control is placed in the regional O-Cloud, and there is a single vO-DU for all network slices. Only the placement of the vO-CU-UP differs, depending on the network slice. The diagram of how network functions map to network elements for scenario C.1 is shown in Figure 2-6 (please note that in Scenario C.1, the E1 interface between CU-CP and CU-UP is explicitly used, unlike in Scenario C or C.2). + +![Figure 2-6: Cloud deployment scenario C.1. The diagram shows a 1:M relationship between Regional cloud and Edge cloud, and a 1:N relationship between Edge cloud and Cell site. The Regional cloud contains Near-RT RIC, vO-CU-CP, vO-CU-UP1, and Cloud Platform. The Edge cloud contains vO-CU-UP2, vO-DU, and Cloud Platform. The Cell site contains O-RU (/RU). Arrows indicate data flow and control planes (E1, E2, F1-c, F1-u). The diagram also shows Open fronthaul and Open chassis and blade spec.](4fef7d15e3675e214e3cb426f24e1dbd_img.jpg) + +Figure 2-6: Cloud deployment scenario C.1. The diagram shows a 1:M relationship between Regional cloud and Edge cloud, and a 1:N relationship between Edge cloud and Cell site. The Regional cloud contains Near-RT RIC, vO-CU-CP, vO-CU-UP1, and Cloud Platform. The Edge cloud contains vO-CU-UP2, vO-DU, and Cloud Platform. The Cell site contains O-RU (/RU). Arrows indicate data flow and control planes (E1, E2, F1-c, F1-u). The diagram also shows Open fronthaul and Open chassis and blade spec. + +**Figure 2-6. Cloud deployment scenario C.1.** + +Table 2-1 is a summary of the cardinality and the distance/delay requirements assumed for this scenario. The URLLC user plane requirements are what drive the placement of the vO-CU-UP function to be in the edge O-Cloud. + +**Table 2-1. Cardinality and Delay Performance for Scenario C.1** + +| | Attribute | RIC – O-CU | O-CU – O-DU | O-DU – O-RU/RU | +|-------------------------------|----------------------|------------|--------------------------------|----------------| +| | Example Cardinality | L= 1 | M=320 | N=100 | +| Delay Max<br>1-way (distance) | mMTC | NA | 625 μs (125 km) | 100 μs (20 km) | +| | eMBB | NA | 625 μs (125 km) | 100 μs (20 km) | +| | URLLC (user/control) | NA | 100 μs (20 km)/625 μs (125 km) | 100 μs (20 km) | + +### 2.2.2 Scenario C.2 + +This is a second variation of Scenario C, which utilizes the same method of placing some vO-CU user plane functionality in the edge O-Cloud, and some in the regional O-Cloud. However, instead of having one vO-DU for all network slices, there are different vO-DU instances in the edge O-Cloud. + +It is driven by factors including the following two use cases: + +- One driver is RAN (O-RU) sharing among operators. In this use case, any operator can flexibly launch vO-CU and vO-DU instances at edge or regional O-Cloud site. For example, as shown in Figure 2-7, Operator #1 wants to launch the vO-CU1 instance in the regional O-Cloud, and the vO-DU1 instance at subtending edge O-Cloud + +Image: O-RAN Alliance Logo + +**O-RAN.WG6.CLOUD-REF-v02.00 TS** + +sites. On the other hand, Operator #2 wants to install both the vO-CU2 and vO-DU2 instances at the same regional O-Cloud site. Note that both operators will share the O-RU. + +- Another driver is that, even within a single operator, that operator can customize scheduler functions depending on the network slice types, and can place the vO-CU and vO-DU instances depending on the network slice types. For example, an operator may launch both vO-CU and vO-DU at the edge O-Cloud site (see Operator #2 below) to provide a URLLC service. + +![Figure 2-7. Treatment of Network Slice: MEC for URLLC at Edge Cloud, Separate vO-DUs](ee3f9deb5400694f99d7c4a4fe297104_img.jpg) + +The diagram shows two operators sharing an O-RU at a Cell site. Operator #1 has vO-CU1 in the Regional Cloud and vO-DU1 in the Edge Cloud, supporting Slice1 (mMTC) and Slice2 (eMBB). Operator #2 has both vO-CU2 and vO-DU2 in the Edge Cloud, supporting Slice3 (URLLC) with UPF/MEC also located at the Edge Cloud. + +Figure 2-7. Treatment of Network Slice: MEC for URLLC at Edge Cloud, Separate vO-DUs + +**Figure 2-7. Treatment of Network Slice: MEC for URLLC at Edge Cloud, Separate vO-DUs** + +The diagram of how network functions map to network elements for scenario C.2 is shown in Figure 2-8. + +![Figure 2-8. Cloud deployment scenario C.2.](e94cbad3fc94494831c157c493684f5b_img.jpg) + +The diagram illustrates Cloud deployment scenario C.2. It shows a Regional cloud containing Near-RT RIC and vO-CU1 on a Cloud Platform (Open chassis and blade spec), connected via E2 and F1 interfaces to the Edge cloud. The Edge cloud contains vO-CU2 and vO-DU1/vO-DU2 on a Cloud Platform. The Edge cloud connects to the O-RU (/RU) at the Cell site via Open fronthaul, optionally through a GW. + +Figure 2-8. Cloud deployment scenario C.2. + +**Figure 2-8. Cloud deployment scenario C.2.** + +The performance requirements are the same as those discussed earlier for Scenario C.1 in Section 2.2.1, with one exception, namely, for the URLLC slice in Scenario C.2 the CU-CP and CU-UP delays are the same (i.e., they are collocated on the edge cloud in this particular example). + +# Chapter 3 Operator Requirements + +## 3.1 Typical Use Cases + +Typical use cases include mobile wireless coverage for large metropolitan areas with operator requirements as shown in Table 3-1 to Table 3-7. + +| Carrier Type | Component Carrier Bandwidth | Number of Layers (Downlink) | Number of Aggregated Carriers | Total Aggregated Bandwidth | +|--------------|-----------------------------|-----------------------------|-------------------------------|----------------------------| +| LTE | 20 MHz | 4 layers | 5 carriers | 400 MHz | +| NR Sub-6 GHz | 20 MHz | 16 layers | 5 carriers | 1600 MHz | +| mmWave | 100 MHz | 2 layers | 8 carriers | 1600 MHz | + +**Table 3-1. AT&T Carrier aggregation requirements.** + +Copyright © 2021 by O-RAN ALLIANCE e.V. +Your use is subject to the terms of the O-RAN Adopter License Agreement in the Annex ZZZ. + +12 + +| Carrier Type | Component Carrier Bandwidth | Number of Layers | Number of Aggregated Carriers | Total Aggregated Bandwidth | +|--------------|-----------------------------|------------------|-------------------------------|----------------------------| +| LTE | 5-20 MHz | 2, 4 layers | 3-5 carriers | 80-400 MHz | +| NR Sub-6 GHz | 20-100 MHz | 4 - 16 layers | 1-3 carriers | Up to 2240 MHz | +| mmWave | FFS | FFS | FFS | FFS | + +**Table 3-2. Deutsche Telekom carrier aggregation requirements.** + +| Carrier Type | Component Carrier Bandwidth | Number of Layers | Number of Aggregated Carriers | Total Aggregated Bandwidth | +|--------------|-----------------------------|------------------|-------------------------------|----------------------------| +| LTE | 20 MHz | 4 layers | 4 carriers | 320 MHz | +| NR Sub-6 GHz | 100 MHz | 8 or 16 layers | 1 carrier | Up to 1600 MHz | +| mmWave | FFS | FFS | FFS | FFS | + +**Table 3-3. Orange carrier aggregation requirements.** + +| Carrier Type | Component Carrier Bandwidth | Number of Layers (Downlink) | Number of Aggregated Carriers | Total Aggregated Bandwidth | +|--------------|-----------------------------|-----------------------------|-------------------------------|----------------------------| +| LTE | 5-20 MHz | 4 layers | 3-5 carriers | Up to 400 MHz | +| NR Sub-6 GHz | 100 MHz | 8 – 16 layers | 2 carriers | Up to 3200 MHz | +| mmWave | 100 MHz | 2 layers | 4 carriers | 800 MHz | + +**Table 3-4. KDDI carrier aggregation requirements.** + +| Carrier Type | Component Carrier Bandwidth | Number of Layers (Downlink) | Number of Aggregated Carriers | Total Aggregated Bandwidth | +|--------------|-----------------------------|-----------------------------|-------------------------------|----------------------------| +| LTE | 10MHz, 20MHz | 2, 4 | 2, 3, 4 carriers | 30~80MHz | +| NR Sub-6 GHz | 30MHz, 60MHz, 100MHz | 2, 4 | 2 carriers | 130~200MHz | +| mmWave | FFS | FFS | FFS | FFS | + +**Table 3-5. CMCC carrier aggregation requirements.** + +| Carrier Type | Component Carrier Bandwidth | Number of Layers (Downlink) | Number of Aggregated Carriers | Total Aggregated Bandwidth | +|--------------|-----------------------------|-----------------------------|-------------------------------|----------------------------| +| LTE | 5MHz, 10MHz, 15MHz, 20MHz | 2 | 2, 3 carriers | Up to 50MHz | +| NR Sub-6 GHz | 40MHz, 50MHz, 55MHz, 100MHz | 2, 4 | 2, 3 carriers | Up to 300MHz | +| mmWave | FFS | FFS | FFS | FFS | + +**Table 3-6. CTC carrier aggregation requirements.** + +| | | +|----------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------| +| Active UEs (95 <sup>th</sup> percentile) supported per macro sub-6 GHz TRP | 256 (AT&T, others FFS) | +| Active UEs (95th percentile) supported per mmWave TRP | 64 (AT&T, others FFS) | +| Carrier capacity (MHz) per O-DU pool | Up to 56,000 MHz (AT&T, others FFS) | +| O-DU pooling model | Pooled centralization [1] | +| Minimum number of TRPs that an O-DU pool supports | 32 (AT&T and Orange, others FFS) | +| Fronthaul interface to O-DU | O-RAN 7.2x, with low phy in O-RU or FHGW | +| Physical interface to the cloud platform supporting O-DU (e.g., from FHGW) | At least 2x 25Gbps (or higher depending on site configuration) aggregated links to minimize switching latency (2x is for redundancy purposes). | + +**Table 3-7. BBU pooling requirements.** + +## 3.2 Cloud Deployment Requirements + +As Figure 2-1 shows, deployment of a cloud platform occurs in two locations: regional and edge clouds. The physical environment of a regional cloud is typically a modern data center, hosting standard server racks with a 19-inch wide rack enclosure, 42U height, and external depth between 1 and 1.2 meters. In this environment, the cloud platform hardware can use standard rack-mount servers and switches, and does not impose special requirements on the hardware form factors. + +The edge cloud often resides in a traditional telecommunications equipment room with limited space, cooling capacity, floor loading, and so forth. The limitations can impose special requirements on the cloud platform hardware that may require telecommunications standard certifications, such as the Network Equipment Building System (NEBS) requirements found in GR-63-CORE [3] and GR-1089-CORE [4]. For example, the Open Telecom IT Infrastructure (OTII) Project specifies a 2U rack server with depth less than 450 mm [5][3]. In addition, the Open Compute Project (OCP) operates an openEDGE project [6], which specifies a compact cloud platform that has the extended environmental requirements often needed in edge deployments. + +### 3.2.1 Regional Cloud + +A regional cloud hosts the near-RT RIC, which includes Radio Connection Management, Mobility Management, QoS Management, Interference Management, Radio-Network Information Base, and possibly 3<sup>rd</sup>-party applications. A typical regional cloud has the following characteristics: + +- Standard Internet Data Center (IDC) environment; +- At least one standard 19-inch rack with a top-of-rack (TOR) switch and five servers; +- Highly available cloud platform software; +- Highly available network topology; +- Highly available storage system in the form of traditional storage area network (SAN), software-defined storage (SDS), or combination of the two. + +In Scenario C (and its variants C.1/C.2), a regional cloud will also host the O-CU functions. + +### 3.2.2 Edge Cloud + +The edge cloud is often deployed in a relatively rough physical environment with typical characteristics in Table 3-8. + +| | | +|-------------------|---------------------------------------------------------------------------------------------------------| +| Rack Form Factors | 19-inch width, 600mm depth | +| Temperature Range | Long-term: -5°C to 45°C (ETSI EN300 019-1-3 Class 3.2 [7])<br>Short-term: -5°C to 55°C (GR-63-CORE [3]) | +| Humidity | Operating humidity: 5% to 95%<br>Long-term: 5% to 85%<br>Short-term: 5% to 90% | + +| | | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| EMC | EN300386 (v1.6.1) [8]<br>FCC CFR47 15 (class A) [9], CISPR 22/32 (class A) [10], CISPR 24 [11]<br>TEC/EMI/TEL-001/01/FEB-09 [12] and TEC/IR/SWN-2MB/07/MAR-10 [13]<br>GR-1089-CORE [4] | +| Equipment Center | Class A (Telecom center); Class B (Non-telecom center) | +| Seismic | GR-63-CORE (Zone 4) [3] | +| Safety | IEC 62368-1:2014 [14]<br>GR-63-CORE (Electrical safety, grounding and bonding) [3] | +| Acoustic Noise | GR-63-CORE (equipment room criteria) [3] | +| Fire Resistance | GR-63-CORE (shelf level criteria) [3] | +| Power Supply | 208V AC, 220V AC, or -48V DC (-60V DC in Germany) | + +**Table 3-8. Edge cloud environmental characteristics.** + +# Chapter 4 O-Cloud Requirements + +This chapter describes design requirements for the O-Cloud. While most requirements apply to both the regional and edge O-Clouds, the edge O-Cloud may impose unique requirements, e.g., hardware accelerators, which will be noted specifically. In addition, depending on the implementation choices for O-CU, O-DU, and near-RT RIC, the O-Cloud needs to provide support for virtual machines or containers. + +## 4.1 O-Cloud Architectural Components and Requirements + +![Figure 4-1: Architecture component requirements for the cloud platform. The diagram shows a layered architecture. At the top is 'Virtualized/Containerized O-RAN Functions'. Below this is the 'Cloud Platform Software' layer, which includes 'VM/Container Management and Orchestration' (with sub-components: VM/Container Mgmt, VM/Container Orchestration, VM/Container Storage, VM/Container Networking), 'Cloud Platform Management' (with sub-components: Node Feature Mgmt, Configuration Mgmt, Software Mgmt, User Mgmt, HW Accelerator Mgmt (for O-Cloud), Host Mgmt, Service Mgmt, HA Mgmt, Fault Mgmt), and 'Cloud Platform Runtime' (with sub-components: Hypervisor/Container Runtime, Accelerator Driver (for O-Cloud), Network Driver, Board Management, PTP, Software defined Storage). Below the software layer is the 'Operating System' layer. At the bottom is the 'Cloud Platform Hardware' layer, which includes 'HW Accelerators (for O-Cloud)', 'Server', 'Switch', and 'Storage'.](8dcf1887868849cde56b4d9c15a23a61_img.jpg) + +Figure 4-1: Architecture component requirements for the cloud platform. The diagram shows a layered architecture. At the top is 'Virtualized/Containerized O-RAN Functions'. Below this is the 'Cloud Platform Software' layer, which includes 'VM/Container Management and Orchestration' (with sub-components: VM/Container Mgmt, VM/Container Orchestration, VM/Container Storage, VM/Container Networking), 'Cloud Platform Management' (with sub-components: Node Feature Mgmt, Configuration Mgmt, Software Mgmt, User Mgmt, HW Accelerator Mgmt (for O-Cloud), Host Mgmt, Service Mgmt, HA Mgmt, Fault Mgmt), and 'Cloud Platform Runtime' (with sub-components: Hypervisor/Container Runtime, Accelerator Driver (for O-Cloud), Network Driver, Board Management, PTP, Software defined Storage). Below the software layer is the 'Operating System' layer. At the bottom is the 'Cloud Platform Hardware' layer, which includes 'HW Accelerators (for O-Cloud)', 'Server', 'Switch', and 'Storage'. + +**Figure 4-1. Architecture component requirements for the cloud platform.** + +Figure 4-1 depicts the high-level architecture components for deploying VM/container-based O-RAN functions in the regional and edge O-Clouds. + +The Virtualized/Containerized O-RAN Functions include the O-DU, O-CU and other workloads deployed on the O-Cloud via the O2 interface. + +The VM/Container Management and Orchestration is typically implemented with OpenStack for VM deployments and Kubernetes for container deployments. + +The Cloud Platform Management represents the O-Cloud infrastructure management functions required for life cycle management, high availability, fault management and configuration of the O-Cloud platform. + +The Cloud Platform Runtime represents the additional cloud platform run-time capabilities required to host O-RAN functions as compared to 5G core network functions. + +### 4.1.1 Hardware Requirements + +Table 4-1 shows requirements for the cloud platform hardware. + +| Components | Description | +|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Server | <ul style="list-style-type: none"> <li>Regional cloud: standard COTS server</li> <li>Edge cloud: depth <math>\leq 450\text{mm}</math>, height <math>\leq 2\text{RU}</math>, width <math>\leq 19\text{in}</math></li> <li>Minimum 16-core CPU at 2.2 GHz base frequency and 128 GB DDR4</li> <li>At least 2x 25GbE ports for front-haul interface (or higher, depending on site), 2x 10GbE ports for backhaul interface, and 1x 1GbE out-of-band management port</li> <li>SR-IOV-capable NICs with network link aggregation enabled</li> <li>For single-socket, at least 3 PCI-E slots for 3x HHHH or 1x FHFL + 2x HHHH cards; for dual-socket, at least 4 slots for 4x HHHH or 1x FHFL DW + 3x LP cards</li> <li>All hard disk drives require hot-pluggable</li> <li>Management interfaces support IPMI, SNMP, and Redfish (preferred)</li> <li>UEFI secure boot enabled</li> </ul> | +| Hardware Accelerator | <ul style="list-style-type: none"> <li>Required for O-DU in the edge cloud in forms such as FPGA, ASIC, and GPU</li> <li>At least 2 ports at 10 or 25 Gbps eCPRI/RoE open front-haul interface</li> <li>Acceleration for functions such as LDPC encoding and decoding, and end-to-end high PHY</li> </ul> | +| Switch | <ul style="list-style-type: none"> <li>Standard COTS TOR switch</li> </ul> | +| Storage | <ul style="list-style-type: none"> <li>Software-defined storage (e.g., Ceph) based on COTS servers</li> </ul> | + +**Table 4-1. Requirements for the cloud platform hardware.** + +### 4.1.2 Operating System Requirements + +Table 4-2 shows requirements for the cloud platform operating system. + +| Operating System | Description | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Linux | <ul style="list-style-type: none"> <li>Linux kernel with real-time preemption patches for O-DU workloads (i.e., SMP PREEMPT RT). Real-time kernel patch for O-CU is optional.</li> <li>Deterministic interrupt handling with a maximum latency of 20 <math>\mu\text{s}</math> as measured by cyclictst for system interrupts (e.g., external I/O) and interrupt-based O-CU and O-DU implementations (e.g., those that rely on OS timers)</li> <li>CRI-O and/or CRI plugin containerd support</li> <li>QEMU/KVM (or other types of hypervisor) for virtual machines</li> </ul> | + +**Table 4-2. Requirements for the cloud platform operating system.** + +### 4.1.3 Cloud Platform Runtime Requirements + +Table 4-3 shows requirements for the cloud platform runtime. + +| Runtime Components | Description | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Accelerator Driver | <ul style="list-style-type: none"> <li>Edge cloud: driver for loading, configuring, managing and interfacing with accelerator hardware providing offload functions for O-DU container or VM</li> </ul> | + +| | | +|--------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Crypto Driver | <ul style="list-style-type: none"> <li>• Crypto offload driver for networking and O-CU wireless cipher (optional)</li> </ul> | +| Network Driver | <ul style="list-style-type: none"> <li>• Network driver(s) for front-haul, back-haul, mid-haul, inter container or VM communication, management and storage networks</li> </ul> | +| Board Management | <ul style="list-style-type: none"> <li>• Board management for interfacing with server hardware and sensors</li> </ul> | +| PTP | <ul style="list-style-type: none"> <li>• Precision time protocol for distributing phase, time and synchronization over a packet-based network</li> </ul> | +| Software-defined Storage (SDS) | <ul style="list-style-type: none"> <li>• Software implementation of block storage running on COTS servers, optional for edge cloud and required for regional cloud</li> <li>• If used in edge cloud, required to be hyperconverged; in regional cloud, either hyperconverged or deployed on dedicated storage nodes</li> </ul> | +| Container Runtime | <ul style="list-style-type: none"> <li>• Executes and manages container images on a node</li> </ul> | +| Hypervisor | <ul style="list-style-type: none"> <li>• Allows host to run multiple isolated VMs</li> <li>• Low performance overhead, compared with non-virtualized execution of specified benchmarks, e.g., SPECcpu, fio, L2Fwd, etc. (quantitative requirements FFS)</li> </ul> | + +**Table 4-3. Requirements for the cloud platform runtime.** + +### 4.1.4 Generic Requirements for Cloud Platform Management + +Table 4-4 shows the generic requirements for management of the cloud platform. + +| Components | Description | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Configuration Management | <ul style="list-style-type: none"> <li>• Auto-discovery of new servers added to an O-Cloud</li> <li>• Management of installation parameters such as console, root disks</li> <li>• Configuration of core, memory, huge-page assignments on each server node</li> <li>• Network interfaces and storage assignments</li> <li>• Hardware discovery of CPUs, cores, storage, network ports, hardware accelerators, etc.</li> <li>• Virtual-to-physical CPU core and NUMA node pinning</li> <li>• Virtual NUMA topology configuration</li> <li>• Huge-page memory</li> <li>• Interrupt and thread pinning to virtual and physical cores</li> </ul> | +| Host Management | <ul style="list-style-type: none"> <li>• Life-cycle and availability management of the server</li> <li>• Host failure detection and recovery</li> <li>• Fault monitoring and reporting</li> <li>• Cluster connectivity failure detection and recovery</li> <li>• VM/container failure detection and recovery</li> <li>• Critical process failure detection and recovery</li> <li>• Resource utilization thresholds (e.g., CPU, memory, storage limits)</li> <li>• Network interface states</li> <li>• Hardware sensors and faults</li> <li>• Watchdog</li> <li>• Board management interfaces and out-of-band server management</li> <li>• Hardware sensor monitoring</li> </ul> | +| Service Management | <ul style="list-style-type: none"> <li>• Monitoring of critical platform infrastructure services and processes</li> <li>• Automatic recovery of failed platform infrastructure services and processes</li> </ul> | +| HA Management | <ul style="list-style-type: none"> <li>• High-availability services for supporting cloud platform redundancy</li> </ul> | +| Fault management | <ul style="list-style-type: none"> <li>• Cloud platform infrastructure alarm and fault management.</li> <li>• Ability to set, clear, query, filter, suppress, log and collect alarms</li> </ul> | +| Software Management | <ul style="list-style-type: none"> <li>• Ability to deploy software updates</li> <li>• Support for rolling updates across all nodes of the local O-Cloud</li> <li>• Support for migrating VMs and/or containers within the local O-Cloud for software upgrade procedures</li> </ul> | +| User Management | <ul style="list-style-type: none"> <li>• User authentication and authorization</li> <li>• Isolation of control and resources among different users</li> </ul> | +| Node Feature Management | <ul style="list-style-type: none"> <li>• Detection and setting of node-level policies to align resource allocation choices (i.e. NUMA, SR-IOV, CPU, etc.)</li> </ul> | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| HW Accelerator Management | <ul style="list-style-type: none"> <li>Support for managing hardware accelerators, mapping them to O-RAN applications VMs and/or containers, and updating accelerator firmware</li> </ul> | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +**Table 4-4. Cloud platform management requirements.** + +### 4.1.5 VM/Container Management and Orchestration Requirements + +Table 4-5 shows requirements for VM/container management and orchestration as part of the cloud platform. + +| Components | Description | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| VM/Container Management | <ul style="list-style-type: none"> <li>VM management and scheduling with OpenStack Nova</li> <li>Container management and scheduling with Kubernetes kube-apiserver, kube-scheduler, etcd, kube-controller-manager</li> </ul> | +| VM/Container Orchestration | <ul style="list-style-type: none"> <li>VM orchestration with Heat templates</li> <li>Container orchestration with HELM charts</li> </ul> | +| VM/Container Storage | <ul style="list-style-type: none"> <li>VM storage and image services with OpenStack Glance and Cinder</li> <li>Container persistent volume claims (PVCs)</li> <li>VM/Container Ceph backends for persistent storage (optional)</li> </ul> | +| VM/Container Networking | <ul style="list-style-type: none"> <li>VM networking with OpenStack Neutron</li> <li>Container networking with kube-proxy and CNI</li> </ul> | + +**Table 4-5. Requirements for VM/container management and orchestration.** + +## 4.2 Time Synchronization Requirements + +The synchronization requirements addressed in this document cover only the synchronization aspects of the O-Cloud nodes that are part of the edge cloud. O-Cloud nodes capable of supporting O-DU deployments shall comply with the synchronization requirements associated with the O-DU instances when instantiated on the O-Cloud nodes, as in CUS specification [2]. The requirements in the section address the LLS-C3 configuration where O-DU and O-RU are synchronized from the fronthaul network. Additional configurations are for future study. + +This section assumes that the O-DU is not on the synchronization path to the O-RU, which is the case with the LLS-C3 and LLS-C4 configurations. O-RAN Fronthaul Working Group Control, User and Synchronization Specification (CUS) [2] specifies the time synchronization requirements for the LLS topology configurations. + +O-DU synchronization requirements specified in the CUS [2] are more relaxed than the requirements associated with the O-RU. O-DU is able to meet synchronization requirements while selecting PTP source from connected networks, provided that the synchronization accuracy requirements for the network as specified in CUS [2] are met in such an implementation. As an end application, O-DU may optionally use SyncE along with PTP, or local time source (typically a GNSS receiver), but these options are not considered in this section. For more details on time synchronization requirements, refer to CUS [2]. + +### 4.2.1 G.8275.1 Full Timing Support (FTS) + +Figure 4-2 illustrates a synchronization architecture for an edge site aligned with the CAD [1] LLS-C3 Synchronization Topology where Compute Nodes synchronize their clocks to a Grandmaster Clock via the Fronthaul Network. + +#### LLS-C3 PTP Deployment Architecture + +![Diagram of LLS-C3 PTP Deployment Architecture showing OAM, Management, and Data Networks with O-Cloud and Fronthaul components.](e6937abfd5bc1d1ac4eeaf9c5200a237_img.jpg) + +The diagram illustrates the LLS-C3 PTP Deployment Architecture across three network layers: OAM Network, Management Network, and Data Network. The OAM Network contains O-Cloud Management (OCM) with controllers (controller-0 to controller-N) connected to an NTP. The Management Network contains O-Cloud Compute Nodes (compute-0 to compute-N), each with S PTP Active/Standby functionality. The Data Network contains the O-Cloud Network and Fronthaul Network. A Clock Source (Master, M) is connected to a T-BC (Slave, S) via PTP+SyncE. The T-BC is connected to the Fronthaul Network, which then connects to multiple Cell Sites (O-RU) via S PTP Active/Standby links. A legend indicates Master (M) and Slave (S) roles, Active Link (solid line), and Standby Link (optional, dashed line). + +Diagram of LLS-C3 PTP Deployment Architecture showing OAM, Management, and Data Networks with O-Cloud and Fronthaul components. + +**Figure 4-2. Key LLS-C3 Fronthaul Synchronization in an example implementation in O-Cloud.** + +A distinction is made between the O-Cloud network and the fronthaul network. The O-Cloud network includes all switches and routers in any network path between two O-Cloud nodes. The fronthaul network includes all switches and other transport equipment in any network path between an O-DU capable O-Cloud node and an O-RU. These networks may overlap, with some routers/switches (e.g., the leaf and spine switches in the O-Cloud resource pool) participating in both the O-Cloud network and the fronthaul network. In the case of such overlap, irrespective of the management responsibilities associated with fabric and transport network elements, all network elements in the timing transfer path between the Grandmaster Clock(s) and Slave (subordinate) Clocks are considered to be part of the fronthaul synchronization network from the associated synchronization functionality and profile compliance point of view. + +An O-Cloud synchronized from the fronthaul network, based on full time support, shall follow the following requirements: + +#### O-Cloud node requirements: + +- (1) All O-DU capable O-Cloud nodes shall have at-least one NIC connected to the fronthaul network. Such nodes shall implement PTP Slaves (subordinate) to the fronthaul network that provides the PTP timing synchronization. +- (2) The PTP Slave (subordinate) NICs shall support T-TSC functionality that is fully compliant with PTP profile ITU-T G.8275.1. +- (3) These Slave (subordinate) PTP NICs shall implement according to “1588-2008 - IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems”, section “6.6.5 Generation of PTP message timestamps” reference point A. +- (4) The O-Cloud shall track which nodes supports PTP capable NICs that are connected to the fronthaul network for the purpose of inventorying O-Cloud nodes that satisfy vO-DU synchronization requirements. +- (5) The O-Cloud shall provide the ability to configure an O-Cloud node’s PTP physical port(s) that receives PTP traffic as a PTP Slave (subordinate). The following minimum configuration shall be supported: + - Network Transport – G.8275.1 synchronization over Ethernet (Layer 2); + - Time Stamping – support for hardware time stamping. +- (6) The O-Cloud operating environment (software stack) shall support PTP protocol implementation (1588-2008 - IEEE Standard). For example: in the case when an O-Cloud is based on the Linux OS, this will require support for ptp4l and phc2sys. +- (7) The node clock on each node shall be synchronized from the NIC T-TSC clock(s). For example: in the case when an O-Cloud is based on the Linux OS, this will require support for phc2sys – Synchronization of two clocks, PHC and node clock (a.k.a system clock) when using HW timestamping. +- (8) Administrative access to the PHCs from deployment instances shall not be allowed, as that would interfere with the PHC management from the cloud platform software. The O-Cloud may provide direct read-only access to the PHC counters from the deployment instances. +- (9) When the Slave (subordinate) PTP NIC is connected two at least two ports to the fronthaul network the PTP Slave (subordinate) NIC shall run the Alternative BMCA in order to select its best master clock. + +#### O-Cloud network requirements: + +- (1) All O-Cloud switches that are also part of the fronthaul network shall provide full timing support with the G.8275.1 Telecom Profile. The synchronization performance requirements are specified in the CUS specification [2] for the O-DU LLS-C3 configuration. Although the CUS allows the ITU-T G8275.2 Telecom Profile for partial timing support, O-Cloud requirements and performance with G8275.2 is for future study. +- (2) Time synchronization redundancy should be supported and is up to the operator's discretion. +- (3) O-Cloud network switches that are also part of the fronthaul network shall support untagged L2 Ethernet transport for S-Plane traffic. +- (4) The fronthaul network elements between the GM and RUs shall require implementing SyncE based on O-RU requirements. + +#### Recommendations: + +All physical network elements that are in the synchronization transfer path (i.e. PRTC/T-GM, switches that act as T-BC, and all O-Cloud node Slaves (subordinate) that act as T-TSC) should implement a 1PPS output interface of the associated Network Elements local clock to facilitate connection to external performance test equipment for performance validation purposes. + +Note: If the O-RUs are synchronized from the same clock(s), which is expected to be a typical case, O-RU rather than O-DU related synchronization requirements determine the performance classes of the PRTC/T-GM and T-BCs that are on the synchronization distribution path towards the O-RUs. + +Note: The Alternative Best Master Selection Algorithm (BMCA) running in Ordinary Clock or Boundary Clock performs the GM selection. A-BMCA is used for improving the accuracy, to optimize the time distribution with multiple PRTC/T-GMs and providing redundancy. By default, the BMCA runs at least once every Announce message interval. There are two steps for the selection: + +- Data Set Comparison Algorithm to select better source from Grandmaster. Data Sets are compared from the Announce message from Multiple Sources. +- State Selection Update the state of each port based on the selection. This is to set the state of all the ports in the clock to a new state, if needed, to sync with better source of a GM. + +### 4.2.2 G.8275.2 Partial Timing Support (PTS) + +As specified in the CUS specification [2], DU synchronization requirements are more relaxed than the requirements associated with the RU, and CUS specification [2] also allows separate PRTC sources to be used for the synchronization of the RUs and DUs. The use of G.8275.2 Partial Timing Support is allowed for the synchronization of O-Cloud nodes (and instantiated O-DU's), provided that the synchronization accuracy requirements for the O-DU as specified in CUS specification [2] are met in such implementation. The detailed implementation of this configuration is subject for the further study. + +## 4.3 Hardware Acceleration Requirements + +The O-RAN Cloud Architecture document [1] discusses the hardware abstraction considerations for the O-Cloud. It lists two levels of abstraction referring to the deployment model and APIs, and also discusses the management and orchestration considerations that should be supported by such hardware accelerators deployed on the cloud platform. This section describes the types of acceleration as background information and then specifies requirements applicable to the O-Cloud for acceleration hardware abstraction. + +### 4.3.1 Background on Acceleration Types + +Hardware acceleration for the managed functions, such as O-DU and O-CU, can be classified into two types: + +- Interface acceleration: acceleration of I/O data transfers on any interface between 3GPP or O-RAN network functions [16]; +- Algorithm acceleration: acceleration of any algorithm processing within an O-RAN network function. + +Interface acceleration mostly exhibits as acceleration of network traffic transmission and reception, for which SR-IOV NICs, combined with software mechanisms such as DPDK, is commonly used. + +Algorithm acceleration includes acceleration of compute-intensive algorithms in the O-DU and O-CU, utilizing accelerator hardware such as FPGA, GPU, DSP, and ASIC. + +#### 4.3.1.1 Acceleration for the O-DU + +Figure 4-3 illustrates acceleration of the interfaces between the O-DU and other O-RAN network functions and acceleration of the high-PHY algorithms within the O-DU. Table 4-6 shows in more detail the accelerated functions. + +![Figure 4-3: O-DU interface and algorithm acceleration. The diagram shows a 'Compute Node (O-Cloud)' containing an 'O-DU' block. On the left, external components 'O-CU-CP', 'SMO', and 'Near-RT RIC' connect to the O-DU via an 'I/O Accelerator'. Inside the O-DU, these connect to 'F1-C Agent', 'OAM Agent', and 'E2 Agent' respectively. The O-DU is divided into 'L2, L3' (containing 'RRC', 'OAM Manager', 'RLC, MAC') and 'L1' (containing 'High-PHY', 'AAL', and 'PHY Algorithm Accelerator (PCI-E)'). The 'F1-U' interface connects the O-DU to 'O-CU-UP' via an 'I/O Accelerator'. The 'Option 7.2' interface connects the O-DU to 'O-RU' via an 'I/O Accelerator'. The 'High-PHY' block is connected to the 'PHY Algorithm Accelerator (PCI-E)' via an 'AAL' block.](5ed86429e3855b6d5cd5d663081d9a00_img.jpg) + +Figure 4-3: O-DU interface and algorithm acceleration. The diagram shows a 'Compute Node (O-Cloud)' containing an 'O-DU' block. On the left, external components 'O-CU-CP', 'SMO', and 'Near-RT RIC' connect to the O-DU via an 'I/O Accelerator'. Inside the O-DU, these connect to 'F1-C Agent', 'OAM Agent', and 'E2 Agent' respectively. The O-DU is divided into 'L2, L3' (containing 'RRC', 'OAM Manager', 'RLC, MAC') and 'L1' (containing 'High-PHY', 'AAL', and 'PHY Algorithm Accelerator (PCI-E)'). The 'F1-U' interface connects the O-DU to 'O-CU-UP' via an 'I/O Accelerator'. The 'Option 7.2' interface connects the O-DU to 'O-RU' via an 'I/O Accelerator'. The 'High-PHY' block is connected to the 'PHY Algorithm Accelerator (PCI-E)' via an 'AAL' block. + +Figure 4-3. O-DU interface and algorithm acceleration. + +| Accelerated Function | Interface Name | Acceleration Type | +|----------------------------------|----------------|-----------------------------------| +| I/O between O-DU and O-CU-CP | F1-C | Interface acceleration (optional) | +| I/O between O-DU and O-CU-UP | F1-U | Interface acceleration | +| I/O between O-DU and SMO | O1 | Interface acceleration (optional) | +| I/O between O-DU and Near-RT RIC | E2 | Interface acceleration (optional) | +| I/O between O-DU and O-RU | FH7.2 | Interface acceleration | +| High-PHY algorithms | N/A | Algorithm acceleration | + +Table 4-6. O-DU acceleration types. + +#### 4.3.1.2 Acceleration for the O-CU-CP + +Figure 4-4 illustrates acceleration of the interfaces between the O-CU-CP and other O-RAN network functions and acceleration of the security algorithms within the O-CU-CP. Table 4-7 shows in more detail the accelerated functions. + +![Figure 4-4: O-CU-CP interface and algorithm acceleration. The diagram shows the O-CU-CP interface and algorithm acceleration within a Compute Node (O-Cloud). The O-CU-CP is divided into OAM Manager, RRC, RRM/Security, AAL, and Security Algorithm Accelerator (PCI-E). The OAM Manager is connected to OAM Agent and E2 Agent. The RRC is connected to RRM/Security. The RRM/Security is connected to AAL. The AAL is connected to Security Algorithm Accelerator (PCI-E). The OAM Manager is connected to OAM Agent and E2 Agent. The RRC is connected to RRM/Security. The RRM/Security is connected to AAL. The AAL is connected to Security Algorithm Accelerator (PCI-E). The OAM Manager is connected to OAM Agent and E2 Agent. The RRC is connected to RRM/Security. The RRM/Security is connected to AAL. The AAL is connected to Security Algorithm Accelerator (PCI-E).](32028329f0bb7b4196c90d2d2cc0ec9d_img.jpg) + +Figure 4-4: O-CU-CP interface and algorithm acceleration. The diagram shows the O-CU-CP interface and algorithm acceleration within a Compute Node (O-Cloud). The O-CU-CP is divided into OAM Manager, RRC, RRM/Security, AAL, and Security Algorithm Accelerator (PCI-E). The OAM Manager is connected to OAM Agent and E2 Agent. The RRC is connected to RRM/Security. The RRM/Security is connected to AAL. The AAL is connected to Security Algorithm Accelerator (PCI-E). The OAM Manager is connected to OAM Agent and E2 Agent. The RRC is connected to RRM/Security. The RRM/Security is connected to AAL. The AAL is connected to Security Algorithm Accelerator (PCI-E). The OAM Manager is connected to OAM Agent and E2 Agent. The RRC is connected to RRM/Security. The RRM/Security is connected to AAL. The AAL is connected to Security Algorithm Accelerator (PCI-E). + +Figure 4-4. O-CU-CP interface and algorithm acceleration. + +| Accelerated Function | Interface Name | Acceleration Type | +|-------------------------------------|----------------|-----------------------------------| +| I/O between O-CU-CP and O-DU | F1-C | Interface acceleration (optional) | +| I/O between O-CU-CP and SMO | O1 | Interface acceleration (optional) | +| I/O between O-CU-CP and Near-RT RIC | E2 | Interface acceleration (optional) | +| I/O between O-CU-CP and O-CU-UP | E1 | Interface acceleration (optional) | +| I/O between O-CU-CP and O-CU-CP | Xn | Interface acceleration (optional) | +| I/O between O-CU-CP and O-CU | X2 | Interface acceleration (optional) | +| I/O between O-CU-CP and MME | S1AP | Interface acceleration (optional) | +| I/O between O-CU-CP and AMF | NG-C | Interface acceleration (optional) | +| Security algorithms | N/A | Algorithm acceleration | + +Table 4-7. O-CU-CP acceleration types. + +#### 4.3.1.3 Acceleration for the O-CU-UP + +Figure 4-5 illustrates acceleration of the interfaces between the O-CU-UP and other O-RAN network functions and acceleration of the security algorithms within the O-CU-UP. Table 4-8 shows in more detail the accelerated functions. + +![Figure 4-5: O-CU-UP interface and algorithm acceleration. The diagram shows the O-CU-UP interface and algorithm acceleration within the Compute Node (O-Cloud). The O-CU-UP is a central component containing the OAM Manager, PDCP, GTP/Security, AAL, and Security Algorithm Accelerator (PCI-E). It is connected to various external components via interfaces: NG-U and S1-U to the UPF (5G) and SAE-GW (4G); SMO to the OAM Agent; Near-RT RIC to the E2 Agent; and E1 to the O-CU-CP. The O-CU-UP is also connected to the O-DU via the F1-U/W1 interface. The O-CU-UP is accelerated by the I/O Accelerator and the Security Algorithm Accelerator (PCI-E).](d32b0e4fdd011862fa39de6668a68c8b_img.jpg) + +Figure 4-5: O-CU-UP interface and algorithm acceleration. The diagram shows the O-CU-UP interface and algorithm acceleration within the Compute Node (O-Cloud). The O-CU-UP is a central component containing the OAM Manager, PDCP, GTP/Security, AAL, and Security Algorithm Accelerator (PCI-E). It is connected to various external components via interfaces: NG-U and S1-U to the UPF (5G) and SAE-GW (4G); SMO to the OAM Agent; Near-RT RIC to the E2 Agent; and E1 to the O-CU-CP. The O-CU-UP is also connected to the O-DU via the F1-U/W1 interface. The O-CU-UP is accelerated by the I/O Accelerator and the Security Algorithm Accelerator (PCI-E). + +Figure 4-5. O-CU-UP interface and algorithm acceleration. + +| Accelerated Function | Interface Name | Acceleration Type | +|-------------------------------------|----------------|-----------------------------------| +| I/O between O-CU-UP and O-DU | F1-U | Interface acceleration | +| I/O between O-CU-UP and SMO | O1 | Interface acceleration (optional) | +| I/O between O-CU-UP and Near-RT RIC | E2 | Interface acceleration (optional) | +| I/O between O-CU-UP and O-CU-CP | E1 | Interface acceleration (optional) | +| I/O between O-CU-UP and SAE-GW | S1U | Interface acceleration | +| I/O between O-CU-UP and UPF | NG-U | Interface acceleration | +| Security algorithms | N/A | Algorithm acceleration | + +Table 4-8. O-CU-UP acceleration types. + +### 4.3.2 Hardware Acceleration Abstraction Layer Requirements + +The Acceleration Abstraction Layer (AAL) provides a set of APIs to VNF/CNF software for offloading certain functions that, for instance, are compute- and power-intensive, to hardware accelerators supported on the O-Cloud platform. The objective of the AAL is to hide the different implementations of hardware accelerators and present APIs to VNF/CNF applications to enable portability and software-and-hardware decoupling. Full listing of the functions that can be offloaded through the AAL is outside the scope of this document. + +#### 4.3.2.1 Generic Requirements + +##### Extensibility + +O-RAN has defined the functions that can be accelerated by the cloud platform based on 3GPP specifications and O-RAN deployment scenarios. However, the AAL API should not limit innovation of future implementations and should evolve as the specification requires. In this way, the API shall be extensible to accommodate future revisions of the specification. + +##### Interrupt and Poll Mode + +The API shall allow multiple design choices for application vendors and shall not preclude a vendor from adopting an interrupt-driven design or poll-mode design or any combination of both. As such, the API shall support both interrupt mode and poll mode for the data-path application interface. + +##### Discovery and Configuration + +The API shall support application software to discover and configure the accelerator hardware. The API shall allow an application to discover what physical resources have been assigned to it from the upper layers and then to configure said resources for offload operations. + +##### Multiple Device Support + +There may be scenarios where multiple hardware accelerators (either implementing the same acceleration function or different) are assigned to a single application, which uses one or more of these accelerators as needed. The API shall support an application using one or more accelerator devices at the same time, as Figure 4-6 illustrates. + +![Figure 4-6: AAL support for multiple devices. The diagram shows an 'Application' box at the top, connected to an 'API' box below it. The 'API' box is connected to two separate 'Function' boxes, each labeled 'HW Accelerator' below it. Arrows point from the 'Application' to the 'API', and from the 'API' to each 'Function' box.](fe8378a4dd8dd937c1a943678a5a2782_img.jpg) + +``` + +graph TD + Application[Application] --> API[API] + API --> Function1[Function +HW Accelerator] + API --> Function2[Function +HW Accelerator] + +``` + +Figure 4-6: AAL support for multiple devices. The diagram shows an 'Application' box at the top, connected to an 'API' box below it. The 'API' box is connected to two separate 'Function' boxes, each labeled 'HW Accelerator' below it. Arrows point from the 'Application' to the 'API', and from the 'API' to each 'Function' box. + +Figure 4-6. AAL support for multiple devices. + +#### 4.3.2.2 API offload requirements + +The API in supporting different implementations shall support different offload architectures including look-aside, inline, and any combination of both. + +##### Look-aside Acceleration Model + +The API shall support look-aside acceleration model where the host CPU invokes an accelerator for data processing and receives the result after processing is complete. A look-aside architecture, illustrated in Figure 4-7, allows the application to offload work to a hardware accelerator and continue to perform other work in parallel—this could be to continue to execute other software tasks in parallel or to sleep and wait for the accelerator hardware to complete. This model requires the API to support two operations, one for initiating the offload and another for retrieving the operation once complete. + +![Figure 4-7: AAL look-aside acceleration model. The diagram shows a 'CPU' box at the top containing 'VNF/CNF' and 'API'. Below it is a 'HW Accelerator' box containing 'CPU Interface' and 'Look-aside Accelerator'. A downward arrow points from the 'API' to the 'CPU Interface', and an upward arrow points from the 'CPU Interface' back to the 'API'.](6444cfc61ebec29ffc27dcb692576aa8_img.jpg) + +``` + +graph TD + subgraph CPU_Box [CPU] + VNF_CNF[VNF/CNF] + API[API] + end + subgraph HW_Accelerator_Box [HW Accelerator] + CPU_Interface[CPU Interface] + Look_Aside_Accelerator[Look-aside Accelerator] + end + API --> CPU_Interface + CPU_Interface --> API + +``` + +Figure 4-7: AAL look-aside acceleration model. The diagram shows a 'CPU' box at the top containing 'VNF/CNF' and 'API'. Below it is a 'HW Accelerator' box containing 'CPU Interface' and 'Look-aside Accelerator'. A downward arrow points from the 'API' to the 'CPU Interface', and an upward arrow points from the 'CPU Interface' back to the 'API'. + +Figure 4-7. AAL look-aside acceleration model. + +##### Inline Acceleration Model + +The API shall support inline acceleration model where acceleration by function and I/O-based acceleration are performed on the physical interface as the packet ingresses/egresses the platform. Figure 4-8 shows one possible implementation of an inline acceleration model. + +![Figure 4-8: AAL inline acceleration model diagram. The diagram shows a CPU block at the top containing a VNF/CNF block with an API interface. Below the CPU is a HW Accel block. A CPU Interface connects the CPU to the HW Accel. Inside the HW Accel, there are two Func blocks. Data flows from the CPU Interface to the left Func block, then to a Tx block, and finally out of the HW Accel. Data flows from an Rx block into the HW Accel, through the right Func block, and back to the CPU Interface. The Tx and Rx blocks are connected to an external interface.](633a25fb7963a57a9ca93c98dd3e0543_img.jpg) + +``` + +graph TD + subgraph CPU + VNF_CNF[VNF/CNF] + API[API] + end + subgraph HW_Accel [HW Accel] + CPU_Interface[CPU Interface] + Func1[Func] + Func2[Func] + Tx[Tx] + Rx[Rx] + end + CPU_Interface <--> API + CPU_Interface --> Func1 + Func1 --> Tx + Tx --> Out[ ] + In[ ] --> Rx + Rx --> Func2 + Func2 --> CPU_Interface + style Out fill:none,stroke:none + style In fill:none,stroke:none + +``` + +Figure 4-8: AAL inline acceleration model diagram. The diagram shows a CPU block at the top containing a VNF/CNF block with an API interface. Below the CPU is a HW Accel block. A CPU Interface connects the CPU to the HW Accel. Inside the HW Accel, there are two Func blocks. Data flows from the CPU Interface to the left Func block, then to a Tx block, and finally out of the HW Accel. Data flows from an Rx block into the HW Accel, through the right Func block, and back to the CPU Interface. The Tx and Rx blocks are connected to an external interface. + +**Figure 4-8. AAL inline acceleration model.** + +In Figure 4-8, a “Func” block refers to some algorithmic function that is accelerated in the device before the data egresses or ingresses from the acceleration device. “Tx” refers to the transmission of the data from the acceleration device to an Ethernet interface, while ‘Rx’ refers to the reception of data from the Ethernet interface to the acceleration device. + +While the look-aside architecture shall support dataflow from the CPU to the accelerator and back to the CPU before being sent to the front-haul interface, the inline architecture shall support data flow from the CPU to the accelerator and directly from the accelerator to the front-haul interface, instead of being sent back to the CPU. The typical data flows for accelerating the O-DU high-PHY functions for the look-aside and inline architectures are as follows. + +##### Look-aside architecture dataflow + +CPU ↔ accelerator ↔ CPU ↔ front-haul: for a set of consecutive PHY functions offload (e.g., FEC) + +CPU ↔ accelerator ↔ CPU ↔ accelerator ↔ ... ↔ CPU ↔ front-haul: for a set of non-consecutive PHY functions offload + +##### Inline architecture dataflow + +CPU ↔ accelerator ↔ front-haul: for a set of consecutive PHY functions offload (up to the end of the PHY pipeline) + +Figure 4-9 illustrates one possible implementation of the look-aside and inline architectures. While a set of PHY-layer functions are offloaded to the accelerator hardware for look-aside acceleration, the entire end-to-end high PHY pipeline is offloaded to the accelerator for inline acceleration. + +![Figure 4-9: Dataflow paths in look-aside and inline acceleration architectures. The diagram shows two main architectures: Look-aside model and Inline model. In the Look-aside model, L2+ on CPU connects via L1/L2 interface* to a High PHY on CPU block containing Func. 1, 3, 4, ..., n. This block connects to an AAL block, which then connects to Func. 2 on accelerator and Func. (n-1) on accelerator. In the Inline model, L2+ on CPU connects via L1/L2 interface* to an Accelerator interface on CPU, which connects to a High PHY on accelerator block containing Func. 1, 2, 3, ..., n-1, n. Both models connect to a Fronthaul interface and then to an RRU via FH (7.2). A legend indicates I/O data flow (grey double arrow), PHY downlink (red arrow), and PHY uplink (purple arrow).](47542ea408142db34c7b4b3e4c12db3d_img.jpg) + +Look-aside model + +Inline model + +O-DU + +L2+ on CPU + +L1/L2 interface\* + +High PHY on CPU + +Func. 1 + +Func. 3 + +Func. 4 + +... + +Func. n + +AAL + +Func. 2 on accelerator + +Func. (n-1) on accelerator + +Fronthaul interface + +FH (7.2) + +RRU + +\*e.g. FAPI + +Accelerator interface on CPU + +High PHY on accelerator + +Func. 1 + +Func. 2 + +Func. 3 + +... + +Func. n-1 + +Func. n + +Fronthaul interface + +FH (7.2) + +RRU + +I/O data flow + +PHY downlink + +PHY uplink + +Figure 4-9: Dataflow paths in look-aside and inline acceleration architectures. The diagram shows two main architectures: Look-aside model and Inline model. In the Look-aside model, L2+ on CPU connects via L1/L2 interface\* to a High PHY on CPU block containing Func. 1, 3, 4, ..., n. This block connects to an AAL block, which then connects to Func. 2 on accelerator and Func. (n-1) on accelerator. In the Inline model, L2+ on CPU connects via L1/L2 interface\* to an Accelerator interface on CPU, which connects to a High PHY on accelerator block containing Func. 1, 2, 3, ..., n-1, n. Both models connect to a Fronthaul interface and then to an RRU via FH (7.2). A legend indicates I/O data flow (grey double arrow), PHY downlink (red arrow), and PHY uplink (purple arrow). + +Figure 4-9. Dataflow paths in look-aside and inline acceleration architectures. + +##### API Concurrency and Parallelism + +To enable greater flexibility and design choice by application vendors, the API shall support multi-threading environment allowing an application to offload acceleration requests in parallel from several threads. + +# Chapter 5 (Informative) Cloud Platform Design Example + +This chapter includes some possible platform configurations for the regional and edge clouds for both the cloud platform hardware and software. These platform configurations are informative examples only, not normative, and focus on sub-6GHz scenarios. Support for mmWave and quantification of capacities of these example designs (such as the number of cells, data rates, and so forth) have not been systemized or validated and will be further studied in the next release of this document. + +## 5.1 Cloud Platform Hardware Design Example + +This section specifies the cloud platform hardware with a focus on server and accelerator hardware. These informative designs are some examples only. This document focuses on x86 processor-based cloud server design; it will address ARM processor-based designs in a future release. + +### 5.1.1 Regional Cloud Server Example + +Table 5-1 shows an example design for the regional cloud servers. + +| | | +|-----------------|---------------------------------------------------------------------------------------------| +| Processor | 2x 20-core CPUs at 2.4 GHz, e.g., 2 <sup>nd</sup> -generation Intel Xeon Scalable Processor | +| Memory | 12x 32 GB, 2400 MHz TruDDR4 | +| Expansion Slots | 6x PCIe 3.0 | +| Drive Bays | 14x 3.5" or 24x 2.5" hot-swap bays or 24x NVMe bays | + +| | | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| +| RAID support | RAID 1, 12 Gb/s | +| Network Interface | 4x 10GbE/25GbE ports, 1 dedicated 1GbE management port, e.g., 1x Fortville 40GbE Ethernet PCIe XL710-QDA2 Dual Port QSFP+ (PCI-E card direct to CPU 0) | +| Network link aggregation | Enabled | +| Power | 2x hot swap/redundant; support 220V/380V AC, 480V and -48V DC | +| Security | TPM or TCM | +| Availability | Hot-swap fans/PSUs; 45°C continuous operation; light path diagnostic LEDs; front-access diagnostics via dedicated USB port | +| Manageability | Support for IPMI, SNMP, and Redfish | + +**Table 5-1. Regional cloud server example design.** + +### 5.1.2 Edge Cloud Server Example + +Table 5-2 shows an example design for the edge cloud servers with FPGA based acceleration. + +| | | +|-------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Form factors | Depth ≤ 450mm, height ≤ 2RU, width ≤ 19in | +| Processor | 2 <sup>nd</sup> -generation Intel Xeon Gold (e.g., 6210U) or Xeon D-2187NT (16-core) or Xeon D-2177NT (14-core); hyperthreading enabled for O-CU, disabled for O-DU<br><br>Note: the NT models have Intel QAT integrated with the CPU and can perform PDCP crypto acceleration in the vO-CU (when applicable, i.e., for Scenario B and C.1/C2). | +| Memory | 12x 32 GB, 2400 MHz TruDDR4 | +| Expansion Slots | At least 2x half-height half-length (HHHL) or 1x HHHL and 1x FHFL | +| Drive Bays | 6x hot-swappable 2.5-inch SATA or SAS drives; 2x NVMe drives; all drives accessible from front panel | +| RAID support | RAID1 | +| Network Interface | 4x 10GbE/25GbE ports, 1 dedicated 1GbE management port, 1x Fortville 40GbE Ethernet PCIe XL710-QDA2 Dual Port QSFP+ (PCI-E card direct to CPU 0), network cabling at front panel | +| PSU | <ul style="list-style-type: none"> <li>• 1+1 redundant</li> <li>• Hot-swappable</li> <li>• Support for 220V AC or -48V DC</li> <li>• PSUs are connected through the rear panel (AT&T, China Mobile) or front panel (China Telecom, DT, KDDI, Orange)</li> </ul> | +| Temperature | -5° C ~ 55° C (-10° C to 60° C preferred) | +| Security | TPM or TCM | +| Availability | Hot-swap fans/PSUs; 45°C continuous operation; light path diagnostic LEDs; front-access diagnostics via dedicated USB port | +| Manageability | Support for IPMI, SNMP, and Redfish | +| Acceleration<br>(look-aside, FEC profile) | Intel® Programable Acceleration Card N3000, PCIe x16 Gen3, FHHL, I/O 2x25Gbe per QSFP28, FEC Profile 15Gbps Uplink, 5Gbps Downlink, Up to 8 VFs. | + +**Table 5-2. Edge cloud server example design with FPGA acceleration.** + +Table 5-3 shows an example design for the edge cloud servers with GPU based acceleration. + +| | | +|--------------|-------------------------------------------| +| Form factors | Depth ≤ 450mm, height ≤ 2RU, width ≤ 19in | +|--------------|-------------------------------------------| + +| | | +|-----------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Processor | 12C x86 CPU complex or better (e.g. Xeon) | +| Memory | 64 GB, 2400 MHz; or higher | +| Expansion Slots | At least 1x HHHL and 1x FHFL Dual Slot | +| Drive Bays | 6x hot-swappable 2.5-inch SATA or SAS drives; 2x NVMe drives; all drives accessible from front panel | +| RAID support | RAID1 | +| Network Interface | 2x 100/50/25/10 GbE ports, 1 dedicated 1GbE management port, 1x Mellanox ConnectX <sup>®</sup> -6 Dx (with crypto offload support, eCPRI offload with 5T for 5G technology)<br><br>Efficient peer-to-peer support, either through root complex, or external PCIe switch (such as ExpressLane™ PEX 8747) recommended for high bandwidth use cases (like multi-carrier 100MHz massive MIMO systems) | +| PSU | <ul style="list-style-type: none"> <li>1+1 redundant</li> <li>Hot-swappable</li> <li>Support for 220V AC or -48V DC</li> <li>PSUs are connected through the rear panel (AT&T, China Mobile) or front panel (China Telecom, DT, KDDI, Orange)</li> </ul> | +| Temperature | -5 ° C ~ 55 ° C (-10 ° C to 60 ° C preferred) | +| Security | TPM | +| Availability | Hot-swap fans/PSUs; 45°C continuous operation; light path diagnostic LEDs; front-access diagnostics via dedicated USB port | +| Manageability | Support for IPMI, SNMP, and Redfish | +| Acceleration<br><br>(inline, end-to-end HIGH PHY profile) | NVIDIA <sup>®</sup> T4, PCIe x16/x8 Gen3, HHHL (for smaller capacity, low band deployments).<br><br>NVIDIA <sup>®</sup> Tesla <sup>®</sup> V100_PCIe x16 Gen3, FHFL (for higher capacity, to enable support for multi-sector massive MIMO (100 MHz and above) with advanced beam-forming techniques). | + +**Table 5-3. Edge cloud server example design with GPU acceleration.** + +### 5.1.3 BIOS/UEFI Configurations + +Table 5-4 shows recommended settings for the various edge cloud deployment types. + +| BIOS Setting | Description | Regional Cloud Settings for Maximum Performance (with Turbo mode enabled) | Regional & Edge Cloud with Real Time | Edge Cloud with Strict Real Time Configuration for O-DU | +|---------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------|--------------------------------------|---------------------------------------------------------| +| System Power and Performance Policy | Favor high performance over low power consumption for the entire system (e.g., CPU and memory). | Optional | Enabled | Enabled | +| Intel Hyper-Threading Technology (HT) | Enabling HT doubles the number of (logical) CPU cores. But threads on the same physical core share various core data structures and caches, causing performance interference. It is recommended to enable HT to ensure high system throughput, but for applications such as O-DU in the edge cloud, carefully pin | Enabled | Optional | Optional | + +| | | | | | +|-------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------|-------------|-------------| +| | latency-sensitive threads to dedicated cores to ensure real-time performance. | | | | +| Prefetching | Memory cache prefetching technologies allow prefetching data and instructions into the cache before they are used. In general, prefetching reduces cache misses and increases application performance. | Enabled | Enabled | Enabled | +| Intel virtualization support (VT-x) | CPU hardware support for virtualization. | Enabled | Enabled | Enabled | +| Intel VT for direct I/O (VT-d) | Support for PCI-E passthrough and SRIOV. | Enabled | Enabled | Enabled | +| Intel Turbo Boost Technology | Enabling this feature allows individual CPU cores to run at frequencies higher than the base frequency when the processor has sufficient thermal headroom. Frequent transition between normal and turbo modes, however, can cause non-predictive performance and impact system real-time characteristics. | Enabled | Disabled | Enabled | +| Enhanced Intel SpeedStep Technology | Enhanced SpeedStep is a series of dynamic frequency scaling technologies built into modern Intel microprocessors that allow the clock speed of the processor to be dynamically changed (to different P-states) by software. This allows the processor to meet instantaneous performance needs of the operation being performed, while minimizing power draw and heat generation. In general, disabling this feature avoids CPU frequency changing dynamically and thus facilitates deterministic performance. Enabling this but setting the configurable TDP level in the next setting allows finer control on the frequency that the CPU will run at. | Enabled | Disabled | Enabled | +| Intel Configurable TDP | | Nominal | Nominal | Level 2 | +| Energy-efficient Turbo | Transitions in and out of turbo mode incur extra power and overly frequent transitions are energy inefficient. This feature enables more energy-efficient turbo operation. | Disabled | Disabled | Disabled | +| Hardware P-States | Disabling hardware-controlled P-states avoids unpredicted frequency change and helps achieve deterministic performance. | Disabled | C0/C1 state | C0/C1 state | +| Hardware PM Interrupt | | Disabled | Disabled | Disabled | +| EPP Enable | | Disabled | Disabled | Disabled | +| APS Rocketing | | Disabled | Disabled | Disabled | +| Scalability | | Disabled | Disabled | Disabled | +| PP0-Budget | | Disabled | Disabled | Disabled | + +| | | | | | +|-----------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------|----------|----------| +| CPU C State Control & C1E & Processor C6 | Disabling C-state transitions prevents CPU cores from entering sleep states when there is no task to execute. C-states that are often seen in BIOS settings include C1E, C3, and C6 states. As C-state transitions introduce delay, disabling them helps real-time performance, though at the cost of higher power consumption. | Enabled | Disabled | Disabled | +| Direct Cache Access (DCA) & Data Direct I/O (DDIO) | DCA can only reduce packet reception delay. Another technology, DDIO, reduces delay for both transmission and reception. It is recommended to enable DDIO instead of DCA when both settings are present. | Enabled | Enabled | Enabled | +| Uncore Frequency Scaling | Allow the voltage and frequency of the uncore to be programmed independently. Uncore activities are monitored to optimize the frequency in real time. | Enabled | Disabled | Enabled | +| Memory RAS and Performance Configuration & NUMA Optimized | Enable ACPI tables that are required for NUMA-aware operating systems. | Optional | Optional | Optional | + +Table 5-4. BIOS configurations for strong real-time systems. + +### 5.1.4 Firmware Versions + +Table 5-5 shows firmware versions for the example reference design based on the Intel Server Board S2600WF family. + +| | | +|---------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| BIOS/IFWI | SE5C620.86B.00.01.0013.030920180427 | +| Baseboard Management Controller (BMC) | 1.43.91f76955 | +| Download link | <a href="https://downloadcenter.intel.com/download/27632/Intel-Server-Board-S2600WF-Family-BIOS-and-Firmware-Update-Package-for-UEFI-?product=89005">https://downloadcenter.intel.com/download/27632/Intel-Server-Board-S2600WF-Family-BIOS-and-Firmware-Update-Package-for-UEFI-?product=89005</a> | + +Table 5-5. Firmware for example reference design based on Intel server board S2600WF. + +### 5.1.5 Accelerator Hardware + +For deployment scenario B (see [1] and Section 2.1), the O-DU and the O-CU functions are deployed as VNF(s) or CNF(s) on the edge cloud platform and the Near-RT RIC is deployed as a VNF or CNF on the regional cloud platform. Likewise, for deployment scenario C and its variants C.1/C.2 (see [1] and Section 2.2), the O-CU functions are also deployed as VNF(s) or CNF(s) on the regional cloud platform. This section details the hardware acceleration options for these VNFs/CNFs that the cloud platforms shall provide. + +#### 5.1.5.1 Regional Cloud Platform + +In deployment scenario B, the regional cloud platform provides support for the Near-RT RIC. There is currently no hardware acceleration options required for the Near-RT RIC at this stage of definition but this may evolve in future. + +However, in deployment scenario C, the regional cloud platform also provides support for the O-CU in addition to the Near-RT RIC. The O-CU, depending on performance requirements, may choose to use hardware acceleration (e.g., Intel QAT) for wireless cipher processing, namely 128-EEA3, 128-EIA3, UEA2 and UIA2—depending on configurations. + +#### 5.1.5.2 Edge Cloud Platform + +The O-CU and O-DU may follow the software architecture as defined in the O-RAN WG8 specification [17]. + +##### O-CU Acceleration + +When the O-CU functions are deployed on the edge cloud platform (i.e., scenarios B and C.1/C2), the O-CU, depending on performance requirements, may choose to use hardware acceleration (e.g., Intel QAT) for wireless cipher processing, namely 128-EEA3, 128-EIA3, UEA2 and UIA2—depending on configurations. + +##### O-DU Acceleration + +The O-DU is assumed to use the 7.2 split with the front-end processing (FFT, PRACH) implemented in the O-RU. The remaining O-DU functions are implemented as software running on the edge cloud platform. Depending on the performance requirements, the compute-intensive workloads may be accelerated in hardware using look-aside acceleration or inline acceleration or any combination of both. + +Figure 5-1 shows a high-level architecture of look-aside acceleration with proposed Forward Error Correcting (FEC) functions to be hardware-accelerated for the O-DU. + +![Figure 5-1: Hardware-accelerated FEC functions with look-aside model. The diagram shows two data paths between ORAN 7.2 and Upper Layers. The top path (downward flow) includes: Res Demapper, Channel Estimation, MMSE and Equalizer, TA and PN Comp, Demodulation, Descrambler, Rate De-Matching, LDPC Decoder, and CRC. The bottom path (upward flow) includes: Res mapper, Precoder, Layer Mapper, Modulation Mapper, Scrambler, Rate Matching, LDPC Encoder, and CRC Gen & Segmentation. A legend indicates that blue boxes represent CPU processing and grey boxes represent HW Accelerated processing. In this model, the LDPC Decoder, CRC, and LDPC Encoder are hardware-accelerated.](a28719d471c29f6166dbb0aca4ad7277_img.jpg) + +Figure 5-1: Hardware-accelerated FEC functions with look-aside model. The diagram shows two data paths between ORAN 7.2 and Upper Layers. The top path (downward flow) includes: Res Demapper, Channel Estimation, MMSE and Equalizer, TA and PN Comp, Demodulation, Descrambler, Rate De-Matching, LDPC Decoder, and CRC. The bottom path (upward flow) includes: Res mapper, Precoder, Layer Mapper, Modulation Mapper, Scrambler, Rate Matching, LDPC Encoder, and CRC Gen & Segmentation. A legend indicates that blue boxes represent CPU processing and grey boxes represent HW Accelerated processing. In this model, the LDPC Decoder, CRC, and LDPC Encoder are hardware-accelerated. + +**Figure 5-1. Hardware-accelerated FEC functions with look-aside model.** + +Figure 5-2 shows an example of an inline solution for the O-DU that accelerates the front-end compression and decompression (e.g., Mu-Law and BFP) functions in accelerator hardware before sending to the O-RU. + +![Figure 5-2: Hardware-accelerated front-end functions with inline model. The diagram shows two data paths between ORAN 7.2 and Upper Layers. The top path (downward flow) includes: De-compress, Res Demapper, Channel Estimation, MMSE and Equalizer, TA and PN Comp, Demodulation, Descrambler, Rate De-Matching, LDPC Decoder, and CRC. The bottom path (upward flow) includes: Compress, Res mapper, Precoder, Layer Mapper, Modulation Mapper, Scrambler, Rate Matching, LDPC Encoder, and CRC Gen & Segmentation. A legend indicates that blue boxes represent CPU processing and grey boxes represent HW Accelerated processing. In this model, the De-compress, Compress, and CRC are hardware-accelerated.](d9c4a96b38c95923e089e6ad355c6eed_img.jpg) + +Figure 5-2: Hardware-accelerated front-end functions with inline model. The diagram shows two data paths between ORAN 7.2 and Upper Layers. The top path (downward flow) includes: De-compress, Res Demapper, Channel Estimation, MMSE and Equalizer, TA and PN Comp, Demodulation, Descrambler, Rate De-Matching, LDPC Decoder, and CRC. The bottom path (upward flow) includes: Compress, Res mapper, Precoder, Layer Mapper, Modulation Mapper, Scrambler, Rate Matching, LDPC Encoder, and CRC Gen & Segmentation. A legend indicates that blue boxes represent CPU processing and grey boxes represent HW Accelerated processing. In this model, the De-compress, Compress, and CRC are hardware-accelerated. + +**Figure 5-2. Hardware-accelerated front-end functions with inline model.** + +Figure 5-3 shows a high-level architecture of inline acceleration with end-to-end high PHY functions to be hardware-accelerated. + +![Figure 5-3: Hardware-accelerated end-to-end high-PHY functions with inline model. The diagram shows two pipelines: Downlink PDSCH and Uplink PUSCH. Both pipelines start with an L1/L2 interface connected to RLC and MAC blocks. The Downlink PDSCH pipeline consists of CRC Generation + segmentation, LDPC Encoder, Rate Matching, Scrambler, Mod. Mapper, Layer Mapper, Precoder, and RE Mapper. The Uplink PUSCH pipeline consists of CRC check, LDPC Decoder, De-Rate Matching, De-Scrambler, Demod., MIMO Equalizer, Channel Estimator, and RE Demapper. Both pipelines are connected to an RRU via FH (7.2). A legend indicates that green boxes represent GPU and grey boxes represent CPU.](8b1755f427f4aaa57bcdf4dea68b06b3_img.jpg) + +Figure 5-3: Hardware-accelerated end-to-end high-PHY functions with inline model. The diagram shows two pipelines: Downlink PDSCH and Uplink PUSCH. Both pipelines start with an L1/L2 interface connected to RLC and MAC blocks. The Downlink PDSCH pipeline consists of CRC Generation + segmentation, LDPC Encoder, Rate Matching, Scrambler, Mod. Mapper, Layer Mapper, Precoder, and RE Mapper. The Uplink PUSCH pipeline consists of CRC check, LDPC Decoder, De-Rate Matching, De-Scrambler, Demod., MIMO Equalizer, Channel Estimator, and RE Demapper. Both pipelines are connected to an RRU via FH (7.2). A legend indicates that green boxes represent GPU and grey boxes represent CPU. + +Figure 5-3. Hardware-accelerated end-to-end high-PHY functions with inline model. + +#### 5.1.5.3 High-level Platform Architecture Examples + +Based on the hardware acceleration options above, Figure 5-4 to Figure 5-6 illustrate the system-level platform components required for the cloud platform to support various acceleration architectures for the O-DU and the O-CU, and depicting also both scenarios B and C. + +A cloud platform can also support a combination of accelerator functions, such as inline front-end acceleration and FEC look-aside acceleration. Note that hardware acceleration for O-RAN network functions is desired but a software-only implementation is also possible. + +##### Example 1: O-DU and O-CU look-aside acceleration + +Figure 5-4 shows an example cloud platform and its data flows with look-aside acceleration for both the O-DU (FEC) and O-CU (wireless cipher). + +![Figure 5-4: Cloud platform for look-aside acceleration of O-DU and O-CU. The diagram shows two scenarios, B and C. Scenario B shows O-DU SW processing and O-CU SW processing connected to CPU Cores. O-DU SW processing is connected to HW Accel (FEC) via PCIe. O-CU SW processing is connected to HW Accel (Wireless Cipher) via PCIe. Both are connected to NICs, which are connected to O-RAN 7.2 Front Haul and Back Haul. Scenario C shows a similar setup but with O-DU SW processing connected to CPU Cores via F1. A legend indicates that blue arrows represent Network I/O traffic and red arrows represent Look Aside Acceleration Traffic.](43f58e5ee3ab79a0da81848da97c070a_img.jpg) + +Figure 5-4: Cloud platform for look-aside acceleration of O-DU and O-CU. The diagram shows two scenarios, B and C. Scenario B shows O-DU SW processing and O-CU SW processing connected to CPU Cores. O-DU SW processing is connected to HW Accel (FEC) via PCIe. O-CU SW processing is connected to HW Accel (Wireless Cipher) via PCIe. Both are connected to NICs, which are connected to O-RAN 7.2 Front Haul and Back Haul. Scenario C shows a similar setup but with O-DU SW processing connected to CPU Cores via F1. A legend indicates that blue arrows represent Network I/O traffic and red arrows represent Look Aside Acceleration Traffic. + +Figure 5-4. Cloud platform for look-aside acceleration of O-DU and O-CU. + +##### Example 2: O-DU inline and O-CU look-aside acceleration + +Figure 5-5 shows an example cloud platform with mixed acceleration models, where the O-DU uses the inline model for front-haul processing and the O-CU adopts look-aside acceleration for wireless ciphering. + +![Figure 5-5: Cloud platform for O-DU inline acceleration and O-CU look-aside acceleration. The diagram shows two scenarios, B and C. Scenario B shows O-DU SW processing connected to HW Accel (Front End) via PCIe, which connects to O-RAN 7.2 Front Haul. O-DU SW processing is also connected to CPU Cores, which connect to O-CU SW processing via PCIe. O-CU SW processing is connected to HW Accel (Wireless Cipher) via PCIe, which connects to Back Haul. Scenario C shows O-DU SW processing connected to CPU Cores, which connect to O-CU SW processing via F1. O-CU SW processing is connected to HW Accel (Wireless Cipher) via PCIe, which connects to Back Haul. Both scenarios show Network I/O traffic, Look Aside Acceleration Traffic, and Inline Front End Acceleration & Network I/O.](f01ec052e07c217c5cb59e54f91bc0df_img.jpg) + +Figure 5-5: Cloud platform for O-DU inline acceleration and O-CU look-aside acceleration. The diagram shows two scenarios, B and C. Scenario B shows O-DU SW processing connected to HW Accel (Front End) via PCIe, which connects to O-RAN 7.2 Front Haul. O-DU SW processing is also connected to CPU Cores, which connect to O-CU SW processing via PCIe. O-CU SW processing is connected to HW Accel (Wireless Cipher) via PCIe, which connects to Back Haul. Scenario C shows O-DU SW processing connected to CPU Cores, which connect to O-CU SW processing via F1. O-CU SW processing is connected to HW Accel (Wireless Cipher) via PCIe, which connects to Back Haul. Both scenarios show Network I/O traffic, Look Aside Acceleration Traffic, and Inline Front End Acceleration & Network I/O. + +Figure 5-5. Cloud platform for O-DU inline acceleration and O-CU look-aside acceleration. + +##### Example 3: O-DU end-to-end high-PHY inline acceleration and O-CU look-aside acceleration. + +Figure 5-6 shows an example cloud platform, where the O-DU uses the inline model for the entire high-PHY processing and the O-CU adopts look-aside acceleration for wireless ciphering. + +![Figure 5-6: Cloud platform for O-DU inline acceleration of end-to-end high-PHY. The diagram shows two scenarios, B and C. Scenario B shows O-DU SW processing connected to HW Accel (end-to-end High PHY) via PCIe, which connects to O-RAN 7.2 Front Haul. O-DU SW processing is also connected to CPU Cores, which connect to O-CU SW processing via PCIe. O-CU SW processing is connected to HW Accel (Wireless Cipher) via PCIe, which connects to Back Haul. Scenario C shows O-DU SW processing connected to CPU Cores, which connect to O-CU SW processing via F1. O-CU SW processing is connected to HW Accel (Wireless Cipher) via PCIe, which connects to Back Haul. Both scenarios show Network I/O traffic, O-CU Acceleration Traffic, and Inline Acceleration Traffic.](72c0f5b2f375051074a59e709c800210_img.jpg) + +Figure 5-6: Cloud platform for O-DU inline acceleration of end-to-end high-PHY. The diagram shows two scenarios, B and C. Scenario B shows O-DU SW processing connected to HW Accel (end-to-end High PHY) via PCIe, which connects to O-RAN 7.2 Front Haul. O-DU SW processing is also connected to CPU Cores, which connect to O-CU SW processing via PCIe. O-CU SW processing is connected to HW Accel (Wireless Cipher) via PCIe, which connects to Back Haul. Scenario C shows O-DU SW processing connected to CPU Cores, which connect to O-CU SW processing via F1. O-CU SW processing is connected to HW Accel (Wireless Cipher) via PCIe, which connects to Back Haul. Both scenarios show Network I/O traffic, O-CU Acceleration Traffic, and Inline Acceleration Traffic. + +Figure 5-6. Cloud platform for O-DU inline acceleration of end-to-end high-PHY. + +## 5.2 Cloud Platform Software Reference Design + +This section shows an example reference design for the regional and edge cloud platform software. A single installable package supporting various profiles of the platform software runs in both the regional and edge clouds, and can adjust to the different physical environments and scale requirements. As mentioned in Chapter 2, this document focuses on a container-based cloud platform design and will address VM-based designs in a future release. + +Kubernetes is a common implementation for container orchestration and management. Platform infrastructure management and additional components, such as Kubernetes plugins, must be added for hosting accelerated O-DU and O-CU network functions. + +The regional and edge cloud platform requirements also differ based on the network functions they host. Generally, the edge cloud platform requirements are a superset of the functional requirements of the regional cloud platform. The primary differences relate to hardware acceleration features, real-time Linux, precision time protocol and server node scalability down to a single node for cell-site deployments. + +This reference design focuses on deployment scenario B and C (with its variants C.1/C.2), LLS-C3 clock synchronization, and FPGA and GPU hardware acceleration at the edge cloud. It defines two reference configuration profiles, for the regional cloud and edge cloud. + +### 5.2.1 Common Reference Configurations for all Profiles + +Table 5-6 lists the primary platform software components that are common across the two cloud platform reference configuration profiles. A complete list of packages, version information and build recipes to create a cloud platform meeting the requirements of Section 4.1.3 for container deployment are available in O-RAN SC INF project release B (Bronze release). See [18] for further details. + +| Platform Components | Description | +|---------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Ansible | Orchestration engine for automating configuration management and application deployment.<br><a href="https://ansible.com">ansible.com</a> | +| Ceph | Provides object storage, block storage and POSIX-compliant network file system. See <a href="https://ceph.io">ceph.io</a> . | +| Collectd | Collects system and application performance metrics and provides mechanisms to store values.<br><a href="https://collectd.org">collectd.org</a> | +| Dhcp | Assigns IP address and other network information to hosts. | +| Dnsmasq | Provides Domain Name System forwarder.<br><a href="https://en.wikipedia.org/wiki/Dnsmasq">en.wikipedia.org/wiki/Dnsmasq</a> | +| docker-distribution | Docker registry for storing and distributing images.<br><a href="https://github.com/docker/distribution">github.com/docker/distribution</a> | +| Drbd | Replicated storage. | +| Etd | Distributed key-value store.<br><a href="https://etcd.io">etcd.io</a> | +| Helm | Kubernetes package manager.<br><a href="https://helm.sh">helm.sh</a> | +| helm-charts | Tool for managing charts. Charts are packages of pre-configured Kubernetes resources.<br><a href="https://github.com/helm/charts">github.com/helm/charts</a> | +| ima | Detects if files have been accidentally or maliciously altered, both remotely and locally.<br><a href="https://linux-ima.sourceforge.net">linux-ima.sourceforge.net</a> | +| iptables | Configures the tables from the Linux kernel firewall and the chains and rules it sores.<br><a href="https://en.wikipedia.org/wiki/Iptables">en.wikipedia.org/wiki/Iptables</a> | +| Kubernetes | Automates deployment, scaling and management of containerized applications.<br><a href="https://kubernetes.io">kubernetes.io</a> | +| mariadb | Relational databases.<br><a href="https://mariadb.org">mariadb.org</a> | +| nginx | High-performance HTTP server, reverse proxy and load balancer. | + +| | | +|------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------| +| pxe-network-installer | Provides PXE (preboot execution environment) install server. | +| rabbit-mq | Highly-available and scalable message broker.<br><a href="http://rabbitmq.com">rabbitmq.com</a> | +| redfishtool | Industry standard protocol providing a RESTful interface for the management of servers. | +| tpm2 | Provides trusted platform module support. | +| <b>Kubernetes Components</b> | <b>Description</b> | +| etcd | Distributed key-value store used as Kubernetes backing store for cluster data.<br><a href="http://etcd.io">etcd.io</a> | +| coredns | Kubernetes cluster DNS service. | +| armada | Manages helm chart dependences. | +| calico | Enables networking and network policy in Kubernetes clusters. Calico uses a pure IP networking fabric to provide high-performance networking. | +| nginx-ingress-controller | Enables Kubernetes to configure nginx for load balancing Kubernetes based services | +| tiller | Service that communicates with the Kubernetes API to manage helm packages. | + +**Table 5-6. Common cloud platform reference configurations for all profiles.** + +### 5.2.2 Regional Cloud Reference Configuration Profile + +The regional edge cloud profile is a cluster-based implementation with two redundant cloud platform controller nodes and worker node scalability from one to 200 nodes. In addition to providing a cloud platform for the Near-RT RIC and, additionally for the O-CU in Scenario C, the regional cloud platform provides zero-touch deployment and provisioning and management of the edge clouds. + +The SMO interfaces to the regional cloud platform for deployment of new edge clouds as well as updating and upgrading of the edge cloud platform software. The regional controller functionality is provided by the distributed cloud component. The regional cloud platform requires the common components in Table 5-6, as well as the components in Table 5-7. + +| Components | Description | +|-------------------|--------------------------------------------------------------------------------------------| +| distributed-cloud | Provides centralized controller functions for management (e.g., lifecycle) of edge clouds. | + +**Table 5-7. Regional cloud reference configuration profile.** + +### 5.2.3 Edge Cloud Reference Configuration Profile + +Based on the hardware acceleration choice, the Linux kernel can be “standard” for inline GPU-based acceleration or “real-time” for look-aside FPGA-based acceleration. See Section 5.2.4 for the real-time Linux kernel configuration details. In addition, the edge cloud platform requires the common components in Table 5-6, as well as the components in Table 5-8. + +| Platform Components | Description | +|--------------------------|------------------------------------------------------------------------------------------------------------------| +| distributed-cloud-client | Provides edge cloud client services for distributed cloud function. | +| e1000e-kmod | E1000e driver for Intel® Gigabit NIC (optional – leveraged only if specific Intel hardware support is required). | + +| | | +|------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| gdrCOPY | Provides GPU memory copy library (optional – leveraged only if specific Nvidia hardware support is required). | +| i40e-kmod | I40e driver for Intel® 40G NIC (optional – leveraged only if specific Intel hardware support is required). | +| iavf-kmod | Driver for Intel® Ethernet adaptive virtual function (optional – leveraged only if specific Intel hardware support is required). | +| integrity-kmod | Kernel module for IMA | +| ixgbe-kmod | Ixgbe driver for Intel® 82598 and 82599 based 10G NIC (optional – leveraged only if specific Intel hardware support is required). | +| ixgbev-f-kmod | Driver for Intel® Ethernet adaptive virtual function for 10 Gig NIC (optional – leveraged only if specific Intel hardware support is required). | +| libibverbs-31mlnx1-ofed | Allows user-space processes to use RDMA verbs directly (optional – leveraged only if specific Mellanox hardware support is required). | +| mlnx-ofa-kernel | Driver for Mellanox NICs (optional – leveraged only if specific Mellanox hardware support is required). | +| opae-intel-fpga-driver-kmod | Open Programmable Acceleration Engine (OPAE) Kernel module for Intel FPGA. | +| qat17 | Driver for Intel® QuickAssist Technology (optional – leveraged only if specific Intel hardware support is required). | +| rdma-core-45mlnx1 | Driver for Mellanox RDMA-based interconnect (optional – leveraged only if specific Mellanox hardware support is required) | +| Linuxptp | Provides Precision Time Protocol according to IEEE standard 1588 and telecom profiles G.8265.1, G.8275.1 and G.8275.2<br><a href="http://linuxptp.sourceforge.net">linuxptp.sourceforge.net</a> | +| <b>Kubernetes Plugin/Operators</b> | <b>Description</b> | +| Multus | Multus is a Multi CNi plugin to support the Multi Networking feature in Kubernetes using CRD-based network objects in Kubernetes. The Multus plugin should be used on the master on all nodes to enable the use of multiple network interfaces inside a K8 pod.<br><a href="https://github.com/intel/multus-cni">github.com/intel/multus-cni</a> . | +| FPGA | FPGA Device plugin for FPGA passthrough (optional – leveraged only if specific Intel hardware support is required).<br><a href="https://github.com/intel/intel-device-plugins-for-kubernetes#fpga-device-plugin">github.com/intel/intel-device-plugins-for-kubernetes#fpga-device-plugin</a> | +| QAT | QAT Device plugin for Intel® QAT adapters (optional – leveraged only if specific Intel hardware support is required).<br><a href="https://github.com/intel/intel-device-plugins-for-kubernetes/blob/master/cmd/qat_plugin/">github.com/intel/intel-device-plugins-for-kubernetes/blob/master/cmd/qat_plugin/</a> | +| SR-IOV | The SR-IOV plugin is required to enable the assignment of VFs to containers. SR-IOV provides a low-latency interface for both packet I/O and acceleration interfaces.<br><a href="https://github.com/hustcat/sriov-cni">github.com/hustcat/sriov-cni</a> | +| CPU Manager | The CPU manager for Kubernetes can be used to provide basic core affinity for VNFs and CNFs. It is required to pin real-time threads to specific CPU cores in order to improve performance and meet real-time latency. | + +| | | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <a href="https://github.com/intel/CPU-Manager-for-Kubernetes">github.com/intel/CPU-Manager-for-Kubernetes</a> . | +| Node Feature Discovery | The Node Feature Discovery plugin enables discovering server hardware node features for Kubernetes. It detects hardware features available on each node in a Kubernetes cluster, and advertises those features using node labels.<br><br><a href="https://github.com/kubernetes-sigs/node-feature-discovery">github.com/kubernetes-sigs/node-feature-discovery</a> | +| Node Topology Manager | Node Topology Manager can be used to support NUMA awareness and pinning via the scheduler.<br><br><a href="https://kubernetes.io/docs/tasks/administer-cluster/topology-manager/">kubernetes.io/docs/tasks/administer-cluster/topology-manager/</a> | +| GPU Operator | The GPU operator manages NVIDIA GPU and automates tasks related to bootstrapping GPU enabled nodes (optional – leveraged only if specific Nvidia hardware support is required).<br><br><a href="https://nvidia.github.io/gpu-operator/">nvidia.github.io/gpu-operator/</a> | + +Table 5-8 Edge Cloud Reference Configuration Profile + +### 5.2.4 Example Real-time Linux Configurations + +Table 5-9 shows the reference configurations for the real-time Linux OS. + +| | | | +|---------------------------------------|------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Linux Kernel | 3.10.0-957.21.3.rt56.935.el7.x86_64 | | +| Host or Guest Linux Kernel Parameters | rcu_nocbs=1-N rcu_nocb_poll<br>isolcpus=1-N irqaffinity=0 tsc=perfect<br>nohz_full=1-N idle=poll noswap | N is the total number of logical CPU cores.<br><br>Use the “tuna” tool, provided in some Linux distributions, to configure run-time CPU isolation and thread priorities, if permanent isolation with isolcpus kernel option is not desired. | +| | selinux=0 enforcing=0 | Disable SELinux policies can help improve latency but should only be done if the security considerations are fully understood. | +| | default_hugepagesz=1G hugepagesz=1G<br>hugepages=21 | Use huge pages to minimize TLB miss overhead; use 2MB huge pages when system memory is limited. | +| | usbcore.autosuspend=-1<br>nmi_watchdog=0 softlockup_panic=0<br>cgroup_disable=memory skew_tick=1<br>nosoftlockup | General configurations for real time. | +| | kthread_cpus=0 | Limit host kernel threads to the OS core. Used also in guest assuming a pure user space application design. | +| | intel_pstate=disable<br>intel_idle.max_cstate=0<br>processor.max_cstate=1 | Disabling P-states and limiting C-states in the kernel helps improve real time performance. | +| Host Linux GRUB Parameters | intel_iommu=on iommu=pt<br>pci=pcie_bus_perf | Enable SR-IOV and optimal PCI performance. | +| Host and Guest Tuning | Turn off graphical desktop and unnecessary daemons in the system | | +| | If ext3 or ext4 file system is used, consider using noatime in fstab | | + +| | | +|----------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Host Kernel Command Line example | <pre> BOOT_IMAGE=/vmlinuz-3.10.0-957.21.3.rt56.935.el7.x86_64 root=/dev/mapper/centos-root ro crashkernel=auto nomodeset rd.lvm.lv=centos/root rd.lvm.lv=centos/swap rhgb quiet hugepagesz=1G hugepages=35 default_hugepagesz=1G intel_iommu=on iommu=pt LANG=en_GB.UTF-8 tboot=false biosdevname=0 usbcore.autosuspend=-1 selinux=0 enforcing=0 nmi_watchdog=0 softlockup_panic=0 cgroup_disable=memory skew_tick=1 isolcpus=1-N rcu_nocbs=1-N kthread_cpus=0 irqaffinity=0 nohz_full=1-N nopti_clock=pit no_timer_check pci=pcie_bus_perf clocksource=tsc tsc=perfect idle=poll intel_pstate=disable intel_idle.max_cstate=0 processor.max_cstate=1 nohz=on mce=off nosoftlockup </pre> | +|----------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Table 5-9. Real-time Linux configurations. + +## 5.3 Time Synchronization Reference Design + +Figure 5-7 illustrates an example of the redundant synchronization network for an edge site aligned with the requirements. The O-RUs are expected to be connected to the same leaf-spine fabric, and as such the O-Cloud network is considered to also be part of the fronthaul network. + +![Diagram of CRAN Site Sync Design for LLS-C3, large site. It shows a leaf-spine fabric with Spine #1 to Spine #m. Fronthaul Leaf 1A and Fronthaul Leaf 1B connect to O-RUs. O-Cloud Leaf 1A to O-Cloud Leaf nB connect to O-Cloud nodes (PHC Node 1-1 to PHC Node n-x). Each node has a T-TSC and PHC. A red line indicates the longest intra-site PTP timing transfer path (3 T-BC's) from GNSS Antenna A through PRTC/T-GM A, Spine #1, and O-Cloud Leaf 1A to a node. Legend: Purple box = Fronthaul network (T-BC accuracy class B/C, SyncE may be required based on RU requirements); Blue box = O-Cloud & Fronthaul network (T-BC accuracy class A, SyncE not required).](72c5fd07a7384f5657dbe8ac94a45164_img.jpg) + +**CRAN Site Sync Design – LLS-C3, large site** + +Legend: + +- Fronthaul network (T-BC accuracy class B/C, SyncE may be required based on RU requirements) +- O-Cloud & Fronthaul network (T-BC accuracy class A, SyncE not required) + +Diagram of CRAN Site Sync Design for LLS-C3, large site. It shows a leaf-spine fabric with Spine #1 to Spine #m. Fronthaul Leaf 1A and Fronthaul Leaf 1B connect to O-RUs. O-Cloud Leaf 1A to O-Cloud Leaf nB connect to O-Cloud nodes (PHC Node 1-1 to PHC Node n-x). Each node has a T-TSC and PHC. A red line indicates the longest intra-site PTP timing transfer path (3 T-BC's) from GNSS Antenna A through PRTC/T-GM A, Spine #1, and O-Cloud Leaf 1A to a node. Legend: Purple box = Fronthaul network (T-BC accuracy class B/C, SyncE may be required based on RU requirements); Blue box = O-Cloud & Fronthaul network (T-BC accuracy class A, SyncE not required). + +Figure 5-7. Key synchronization chain elements in an example implementation in O-Cloud for LLS-C3. + +The salient features of this design example are: + +- The synchronization reference sources (PRTC/T-GM) are redundant and located in the edge cloud. In this example, the references are derived from the GNSS system, but any other implementation compliant with the CUS specification [2] requirements (and references therein), which acts as G.8275.1 T-GM, is acceptable. +- The synchronization reference sources are connected to the leaf-spine fabric with redundant Ethernet interconnects. Specifically, each grandmaster connects to at least two leaf switches. +- For larger site configurations (i.e. in which the switch capacity and port count requirements exceed the capabilities of the single physical switch), the structure is expanded in a “leaf-spine” fabric configuration, as illustrated in [2]. For most edge site configurations, it is expected that a two-tier structure is sufficient, which implies that the maximum length of any active synchronization transfer path from co-located sources is three boundary clocks between the grandmaster and any node in the edge cloud. Therefore, the synchronization path “length” in terms of number of boundary clocks that needs to be supportable in this configuration is typically from one to three. Capability to support more nodes in the path is desirable to allow for configurations where the grandmasters are not co-located at the edge cloud. + +- All edge O-Cloud nodes are attached to at least two physically separated, independent leaf switches to provide network redundancy and tolerance against a single point of failure that can affect more than one node (i.e. switch failures). In addition to normal network fault tolerance, this is also useful for maintaining the synchronization network fault tolerance. + +Many alternative variations and physical realizations of the above design are possible (e.g. PRTCs/GMs can be combined with switches or routers, leaf-spine structure can be integrated onto physical box, sizes of elements can vary, etc.), but functionally with respect to the synchronization transfer chain, all of the entities are expected to be present (i.e. PRTC/T-GMs, Telecom Boundary Clock nodes, as well Telecom subordinate Clock nodes). + +For this design example, the O-DU synchronization performance requirements as specified in the CUS specification [2] for the O-DU LLS-C3 configuration expected to be met with the following set of elements in the synchronization transfer path: + +- T-GM A and T-GM B clocks with performance class ITU-T G.8272 PRTC/T-GM type PRTC-B serving as grandmasters for O-DUs as well as O-RUs (O-DUs require PRTC-A or better while O-RUs require PRTC-B) +- The Fronthaul Leafs acting as T-BCs in both the O-RU and O-DU synchronization path, with support for a minimum performance class ITU-T G.8273.2 T-BC Class B (Class C is recommended); +- The Spine and O-Cloud Leaf switches acting as T-BCs in the O-DU synchronization path only, with the least demanding T-BC performance class ITU-T G.8273.2 T-BC Class A or better; +- T-TSC implementation on the O-Cloud nodes with the least demanding performance class ITU-T G.8273.2, Annex C, T-TSC Class A or better. + +# Annex ZZZ: O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN ALLIANCE and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN ALLIANCE that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN ALLIANCE or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN ALLIANCE hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an ORAN + +Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN ALLIANCE. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such + +license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN ALLIANCE on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of ORAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN ALLIANCE or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN ALLIANCE, and cooperates with O-RAN ALLIANCE and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN ALLIANCE's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN ALLIANCE, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN ALLIANCE, which consent may be withheld in O-RAN ALLIANCE's sole discretion. O-RAN ALLIANCE may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN ALLIANCE or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN ALLIANCE or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. + +Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or third party beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full force and effect. \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/0074b9e45b1cc887b698c35894a127bf_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/0074b9e45b1cc887b698c35894a127bf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fcd15ba69647e3007ebe7331315973114b7ee043 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/0074b9e45b1cc887b698c35894a127bf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e3b78eac249a7b444c3ccb6b3ce55bb3859afc6c11b10ad04780549ed3bb832 +size 23417 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/051e3fdd1e2b2d32d521ac6e5ae4950e_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/051e3fdd1e2b2d32d521ac6e5ae4950e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5360254756a33d17477ac48d4051b51bcd3b2c0f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/051e3fdd1e2b2d32d521ac6e5ae4950e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:501ee97e817acac1091a1129ebcef2c49f60f3857cb7023abb719bb9f1eda92e +size 4134 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/092bb7cc741d7ecec1805620eb706e37_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/092bb7cc741d7ecec1805620eb706e37_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fc76e26ba38a260e197cf19f45c16476b6f07443 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/092bb7cc741d7ecec1805620eb706e37_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8d6cd2c5f77923922845429644740d54d0c22dca7c5cbbcc0e016dbec11db3a3 +size 4054 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/181d7a3c6726885270c8f56e1b288c44_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/181d7a3c6726885270c8f56e1b288c44_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b3dd1843da703b70ecb56f9b78be832f91fec1d7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/181d7a3c6726885270c8f56e1b288c44_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:167681713ee6f53c6256a63a9bfa4a6e0b03dc9a5c5c3b2fc18a001edf5cc143 +size 4150 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/1cbd229d6ba5042f2fda12ae38162098_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/1cbd229d6ba5042f2fda12ae38162098_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d2321aef2770f29e830a301a96846e0d707a0550 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/1cbd229d6ba5042f2fda12ae38162098_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:71c05aeec6c37545d773d611f7edca9494b0bc523362adfd2a9d1cf2a6b42ec8 +size 4108 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/4ed047b4bf26a76327ee21fdb2c23d33_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/4ed047b4bf26a76327ee21fdb2c23d33_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..65907544327999b79e285bc2348451d5121ab547 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/4ed047b4bf26a76327ee21fdb2c23d33_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9fbe110e3aa7d3617f28367f9b98e5fdd0899b7d3b812baad8a066f9af91fdd9 +size 4080 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/74aafd85df67d7fb382a03e94b0a46f5_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/74aafd85df67d7fb382a03e94b0a46f5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aca4d3d46b0b58b26feb4d35d5873c1fee083d9a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/74aafd85df67d7fb382a03e94b0a46f5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f30ab0f6de2bfdc808f55f07d464bb135d056ec02bb66e885b8c004cb8f66a16 +size 30565 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/7839aa1b75053a0c232b3c241d43205d_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/7839aa1b75053a0c232b3c241d43205d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9a8ec735ea170bb83de9fde306b173d52f8278ad --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/7839aa1b75053a0c232b3c241d43205d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b088ab4b9d35c726680182059d2cd3bee0078b4e7471e5f4e9c8d4cbcefb46f +size 4104 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/80c440108952adaa91e963ef5cb7d881_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/80c440108952adaa91e963ef5cb7d881_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9d20dbf2c227c84d293985847185834480fd2d0a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/80c440108952adaa91e963ef5cb7d881_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:175cc7d0704e4c7f6966ed545f4920602033593b75ff5fabb621658bd8c52e2f +size 4133 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/8e60b042f04556614670770ecd55d001_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/8e60b042f04556614670770ecd55d001_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..135f9a43bac0845a20451e1c74362ee4422d8e27 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/8e60b042f04556614670770ecd55d001_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:117b417203af4c9fa55b15ed296ab9c00d9d18bf3b31c2e15514b6ebe79b7038 +size 4087 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/9786c0dac9f8ebe0d164c9cca3901408_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/9786c0dac9f8ebe0d164c9cca3901408_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d80c087fd8f79c09ad6dbee432e0ecd3f59622f7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/9786c0dac9f8ebe0d164c9cca3901408_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:00dc6381ce05ddc0b43a36d7b3218f919528c9e6f808c03dbd2c2954401fd3bd +size 4064 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/9e85cb656004806d19c27b1419a85e9e_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/9e85cb656004806d19c27b1419a85e9e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..02a270ce964585ef6ff0d5d7bec3b682ca149bad --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/9e85cb656004806d19c27b1419a85e9e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70e5101245618538448e6d2242c15235a22da524a4418ac747a8275a7346c96c +size 42183 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/d2f6bc4cd2baae0f1c27460b6eccd168_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/d2f6bc4cd2baae0f1c27460b6eccd168_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5511ad33e7665586cb6fc5636a1280297f8846f8 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/d2f6bc4cd2baae0f1c27460b6eccd168_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a45dd0ac57500b76351c2d99e2117005edfb80a94ae9240b8aa8f4860569963d +size 4026 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/d582c6af99cd9c7d1f95b60faa0ea829_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/d582c6af99cd9c7d1f95b60faa0ea829_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cf224727293067fb91dd5f099389c567bdb3b873 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/d582c6af99cd9c7d1f95b60faa0ea829_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bba113327faae38296288c27e3f737c86d378276d9881e945f5d73d5974aab46 +size 4071 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/dcd0b057e1c05cd391e93fbe2a67508f_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/dcd0b057e1c05cd391e93fbe2a67508f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ba022b6d7d3649409f06a0c3afd59e0d658311df --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/dcd0b057e1c05cd391e93fbe2a67508f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:00b161e950dde3b145493fa045e69f8b5610228afbfb7c24404c5ae6b0e1c849 +size 76751 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/f00b403c073afb5136c65addbff6e99a_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/f00b403c073afb5136c65addbff6e99a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aa0f62ae41b120313d3390615f241d94210dbed5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/f00b403c073afb5136c65addbff6e99a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3c962e50238553a5981531ad0b325cd7aa16f824fe035118870c7f6f8fa5ba1f +size 81824 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/raw.md b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..2695fff8f9002763f771e8d0f5781bf87352d375 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00/raw.md @@ -0,0 +1,992 @@ + + +# **O-RAN Working Group 6****O-Cloud Notification API Specification for Event Consumers** --- + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +--- + +# Table of Contents + +| | | +|-------------------------------------------------------------------------------------------------------------------------------------------------------|----| +| Chapter 1 Introductory Material..... | 3 | +| 1.1 Scope | 3 | +| 1.2 References ..... | 3 | +| 1.3 Definitions and Abbreviations ..... | 4 | +| 1.3.1 Definitions..... | 4 | +| 1.3.2 Abbreviations ..... | 4 | +| Chapter 2 Introduction ..... | 5 | +| Chapter 3 Usage of HTTP ..... | 6 | +| 3.1 General ..... | 6 | +| 3.1.1 HTTP/2 shall be transported over Transmission Control Protocol (TCP), as required by HTTP/2 (see IETF RFC 7540 [8]) HTTP standard headers ..... | 6 | +| 3.1.2 Content type ..... | 7 | +| 3.1.3 Void | 7 | +| 3.1.4 Resource addressing..... | 8 | +| Chapter 4 Subscription API Definition ..... | 10 | +| 4.1 Resource Structure ..... | 10 | +| 4.1.1 Resources and HTTP Methods..... | 11 | +| 4.1.2 Subscription resource definition..... | 12 | +| 4.1.3 Individual subscription resource definition..... | 14 | +| Chapter 5 Status Notifications API Definition..... | 17 | +| 5.1 Description ..... | 17 | +| 5.1.1 Event Consumer Notification Resource Definition ..... | 18 | +| Chapter 6 Event Pull Status Notifications API Definition ..... | 22 | +| 6.1 Description ..... | 22 | +| 6.1.1 Resources Pull Status Notification Definition ..... | 23 | +| Chapter 7 Event Data Model..... | 25 | +| 7.1 Subscription Data Model..... | 25 | +| 7.1.1 Structured data types ..... | 25 | +| 7.2 Status Notifications Data Model ..... | 25 | +| 7.2.1 Structured data types ..... | 25 | +| 7.2.2 Event Data Model..... | 26 | +| 7.2.3 Synchronization Event Specifications..... | 28 | +| 7.3 Appendix A ..... | 33 | +| 7.3.1 Helper/Sidecar containers ..... | 33 | +| Helper/Sidecar value: ..... | 33 | + +# Chapter 1 Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN Alliance. + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). + +y the second digit is incremented when editorial only changes have been incorporated in the document. + +z the third digit is included only in working versions of the document indicating incremental changes during the editing process. + +The present document describes a REST API that allows Event Consumers (EC) such as O-RAN NFs to subscribe to events/status from the O-Cloud. The O-Cloud shall provide Event Producers (EP) to enable workloads to receive events/status that might be known only to the Cloud Infrastructure (CInf). + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of this specification (see also <https://www.o-ran.org/specifications>). + +[1] 3GPP TR 21.905, Vocabulary for 3GPP Specifications. + +[2] 3GPP TS 28.622, Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS). + +[3] O-RAN WG1, O-RAN Architecture Description – v02.00, Technical Specification. + +[4] O-RAN WG1, Operations and Maintenance Architecture – v03.00, Technical Specification. + +[5] O-RAN WG4, Control, User and Synchronization Plane Specification – v06.00, Technical Specification. + +[6] O-RAN WG6, Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN – v02.01, Technical Report. + +[7] O-RAN Infrastructure Project, <https://wiki.o-ran-sc.org/display/IN/Infrastructure+Home> + +[8] IETF RFC 7540: "Hypertext Transfer Protocol Version 2 (HTTP/2)". + +[9] IETF RFC 8259: "The JavaScript Object Notation (JSON) Data Interchange Format". + +[10] IETF RFC 7231: "Hypertext Transfer Protocol (HTTP/1.1): Semantics and Content". + +[11] IETF RFC 7230: "Hypertext Transfer Protocol (HTTP/1.1): Message Syntax and Routing". + +[12] IETF RFC 7807: "Problem Details for HTTP APIs". + +[13] IETF RFC 7235 for authentication mechanisms over HTTP/1.1, + +[14] 3GPP TS 29.501, 5G System; Principles and Guidelines for Services Definition + +[15] CloudEvents.io specification, <https://github.com/cloudevents/> + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms given in O-RAN.WG6.CADS [6] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in [6]. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in O-RAN.WG6.CADS [6] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in [6]. + +| | | +|------|---------------------------------| +| EC | Event Consumer | +| EP | Event Producer | +| REST | Representational State Transfer | + +# Chapter 2 Introduction + +This document describes a REST API that allows Event Consumers (EC) such as a vO-DU or CNF to subscribe to events/status from the O-Cloud. The cloud infrastructure will provide Event Producers (EP) to enable cloud workloads to receive events/status that might be known only to the infrastructure. + +An EC will use the REST API to subscribe to specific event types or categories of events by specifying the event / status producer address. The addressing scheme is covered in Resource Addressing. An EC will be able to unsubscribe from receiving events and status by deleting the subscription through the REST API. The REST API is an integration point to an event and status framework that is running in the underlying O-Cloud (IMS and/or DMS). + +The REST API and associated event framework implementation is intended to be used in situations where the path from event detection to event consumption must have the lowest possible latency. Intra-node delivery of events is a primary focus with inter-node delivery also supported. + +The event framework described here is not intended to be an island of communication and should interact with north-bound interfaces such as O2 through the IMS. Hence, this Event Consumers API is not intended to replace O2ims notifications (including PTP loss of sync), but rather to complement it. Please see the CAD [6] for more information. Interfacing with external entities is necessary for communication with orchestrating entities and for permanent storage of event information for root-cause analysis. Communication with external entities is intended to be in one direction with events flowing from this framework outward. The flow of events from this framework to external entities must not affect the latency performance of the framework for intra-node or inter-node delivery. + +Please note that while this API document describes an interface to general events and status provided by the cloud infrastructure, the discussions and examples in this document will focus on events and status related to PTP / Synchronization as it this is the first defined use case that affects the vO-DU per the CUSP [5] requirements. + +*“If an O-DU transits to the FREERUN state, the O-DU shall disable RF transmission on all connected O-RUs, and keep it turned off until synchronization is reacquired.”* + +*“Whether in ‘synchronized’ or ‘Holdover’ state, it is expected that O-DU monitors the ‘SYNCED/HOLDOVER’ status of the O-RUs under its management.”* + +Please note that the timing requirements for notification regarding FREERUN should follow WG4 guidelines when available in the CUSP document. These guidelines may influence the future evolution and design of this API. Please see the CUSP [5] for more information. + +Subscription/Publication use case: + +- Subscription by the Event Consumer (e.g. vO-DU or other CNF) triggers the readiness of the Event Consumer to receive the notifications. +- The REST API handler implementation, provided by the Cloud infrastructure, resides in the application (workload) and is an application appropriate implementation of a REST API handler. +- Upon subscription, the EC will receive an initial notification of the EP resource status. For example, the current synchronization status of the PTP system will be sent to the EC when subscribing to the sync-status address. Or as another example, the current interface carrier status will be sent to the EC when subscribing to the interface-status address. This initial notification allows the joining application to synchronize to the current status of the system being observed. +- Event Consumers will be able to subscribe to resource status notifications offered by the cloud. +- Multiple Event Consumers in the same container, Pod, or VM can subscribe to events and status as the REST API allows multiple receive endpoint URI. +- If the eventing framework cannot provide the requested subscription the eventing framework will deny the subscription request and Event Consumer (vO-DU, vO-CU etc) will be able to make a decision if to proceed with its operation + +# Chapter 3 Usage of HTTP + +## 3.1 General + +HTTP/2, IETF RFC 7540, shall be used. + +3.1.1 HTTP/2 shall be transported over Transmission Control Protocol (TCP), as required by HTTP/2 (see IETF RFC 7540 [8]) HTTP standard headers + +#### 3.1.1.1 Request header fields + +This clause describes the usage of selected HTTP header fields of the request messages in the O-Cloud APIs. + +**Table 3.1.3.2-1: Header fields supported in the request message** + +| Header field name | Reference | Descriptions | +|-------------------|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Accept | IETF RFC 7231 [10] | <p>This field is used to specify response media types that are acceptable by the client sending the request.</p> <p>Content-Types that are acceptable for the response.</p> <p>This header field shall be present in the HTTP request message sent by the client if the response is expected to have a non-empty message body.</p> | +| Content-Type | IETF RFC 7231 [10] | <p>This field is used to indicate the media type of the associated representation.</p> <p>This header field shall be present if the request has a non-empty message body.</p> | +| Authorization | IETF RFC 7235 [13] | The authorization token for the request and is optional. In a local scenario (i.e. within the POD/VM) this is not mandated. If the consumer is external to the POD/VM then Authorization is mandated. | +| Accept-Encoding | IETF RFC 7231 [10] | This field may be used to indicate what response content-encodings (e.g gzip) are acceptable in the response. | +| Content-Length | IETF RFC 7230 [11] | This field is used to provide the anticipated size, as a decimal number of octets, for a potential payload body. | +| Content-Encoding | IETF RFC 7231[10] | This field may be used in some requests to indicate the content encodings (e.g gzip) applied to the resource representation beyond those inherent in the media type. | + +#### 3.1.1.2 Response header fields + +This clause describes the usage of selected HTTP header fields of the response messages in the O-Cloud APIs. + +Table 3.1.3.3-1: Header fields supported in the response message + +| Header field name | Reference | Descriptions | +|-------------------|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Content-Type | IETF RFC 7231 [10] | This header field shall be used to indicate the media type of the associated representation. | +| Content-Length | IETF RFC 7231 [10] | This header field may be used to provide the anticipated size, as a decimal number of octets, for a potential payload body.<br><br>This header field shall be present if the response has a non-empty message body. | +| Location | IETF RFC 7231 [10] | This field may be used in some responses to refer to a specific resource in relation to the response.<br><br>Used in redirection, or when a new resource has been created.<br><br>This header field shall be present if the response status code is 201 or 3xx. | +| Content-Encoding | IETF RFC 7231 [10] | This header may be used in some responses to indicate to the HTTP/2 client the content encodings (e.g gzip) applied to the resource representation beyond those inherent in the media type. | +| WWW-Authenticate | IETF RFC 7235 [13] | Challenge if the corresponding HTTP request has not provided authorization, or error details if the corresponding HTTP request has provided an invalid authorization token. This is optional. When the notification producer and consumer are locally present in the same compute, API authorization is not mandatory. | +| Retry-After | IETF RFC 7231 [10] | Used to indicate how long the user agent ought to wait before making a follow-up request.<br><br>It can be used with 503 responses.<br><br>The value of this field can be an HTTP-date or a number of seconds to delay after the response is received. | + +### 3.1.2 Content type + +JSON, IETF RFC 8259 shall be used as content type of the HTTP bodies specified in the present specification. The use of the JSON format shall be signaled by the content type "application/json". + +"Problem Details" JSON object shall be used to indicate additional details of the error in a HTTP response body and shall be signalled by the content type "application/problem+json", as defined in IETF RFC 7807. + +### 3.1.3 Void + +. + +### 3.1.4 Resource addressing + +The format of the resource address is shown in [Table 1](#). The resource address specifies the Event Producer with a hierarchical path. The path format provides the ability for management and monitoring to extend beyond a single cluster and node. + +**Table 1: Resource address format** + +``` +{/clusterName}/{siteName}{/optional/hierarchy/..}/{nodeName}/{/optional/hierarchy}/resource} +``` + +An example hierarchy could include an IMS and DMS designator i.e., */ims-1/dms-2/node1/sync/sync-status/sync-state*. The event framework is minimally required to support nodeName addressing. The event framework addressing nomenclature for nodeName shall match the O-Cloud technology naming scheme. + +This hierarchy path is part of the environment variables provided to the CNF by the Downward API (see <https://kubernetes.io/docs/tasks/inject-data-application/environment-variable-expose-pod-information/#the-downward-api>) + +Field definitions are shown in [Table 2](#). + +**Table 2: Resource address fields** + +| Address Component | Description | Example | +|---------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| /optional/hierarchy/nodeName/... or<br>././nodeName/... | The hierarchical name that uniquely specifies the DMS where the nodeName node resides. name of the cloud where the producer exists. A '.' is used to indicate the current DMS where the Event Consumer nodeName node is located. The additional hierarchy is optional. If addressing begins with ./ a nodeName or nodeName wildcard is required. | /dms1/nodeName1/... to specify a specif DMS and node, or<br>././nodeName/...1 to specify the current DMS and specific node<br>././..... to specify the current DMS and current node. | +| nodeName | Name of the Worker node or Compute node where the producer exists. The name must map to the nomenclature in use for the underlying cloud infrastructure. A regular expression with * or . may be specified to subscribe to multiple nodes. | node27<br><br>node* -> all nodes<br><br>. -> current node | +| resource | The hierarchical path for the subsystem that will produce the notifications. This path may also include an optional hierarchy to describe different Event Producers in the same Node. The hierarchical path is inclusive such that all notifications for subsystems below the specified path will be delivered | A subscription to <i>/sync</i> would deliver notifications for all types of synchronization events implemented by the synchronization subsystem. Since this cover all notification, individual subscriptions (as described below) will be ignored. | + +| | | | +|--|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>as part of the subscription. The full path can be used to explicitly specify a single type of notification. Multiple subscriptions can be used to select a subset of notification types for event delivery specified level.</p> | <p>A subscription to <i>/sync/sync-status/sync-state</i> would deliver notifications for the event.sync.sync-status.synchronization-state-change event only.</p> <p>Individual subscriptions to <i>/sync/sync-status/sync-state</i> and <i>/sync/gnss-status/gnss-sync-status</i> would deliver notifications for both the overall synchronization health (event.sync.sync-status.synchronization-state-change) and GNSS specific status (event.sync.gnss-status.gnss-state-change).</p> <p>Examples for a ‘resource’ with an optional hierarchy:</p> <p><i>../Node1/NIC1/sync</i></p> <p><i>../Node1/NIC2/sync/sync-status/sync-state/</i></p> <p>Note: In the future, Resource can be expanded to other infrastructure subsystems such as thermal notifications and network interface link status.</p> | +|--|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +# Chapter 4 Subscription API Definition + +## 4.1 Resource Structure + +[Figure 1](#) shows the overall resource URI structure defined for the subscription's API. [Table 3](#) lists the individual resources defined, and the applicable HTTP methods with the message flow diagram, [Figure 2](#). + +**Figure 1: Resource URI structure of the subscription's API** + +![Resource URI structure diagram showing a tree starting from {apiRoot}/ocloudNotifications/{apiVersion}, branching to /subscriptions, which then branches to individual subscription IDs like /{subscriptionId#1[]} and /{subscriptionId#n[]}.](74aafd85df67d7fb382a03e94b0a46f5_img.jpg) + +``` + +graph TD + Root["{apiRoot}/ocloudNotifications/{apiVersion}"] --> Subscriptions["/subscriptions"] + Subscriptions --> Id1["/{subscriptionId#1[]}"] + Subscriptions --> Dots["..."] + Subscriptions --> IdN["/{subscriptionId#n[]}"] + +``` + +Resource URI structure diagram showing a tree starting from {apiRoot}/ocloudNotifications/{apiVersion}, branching to /subscriptions, which then branches to individual subscription IDs like /{subscriptionId#1[]} and /{subscriptionId#n[]}. + +**Figure 2: Message flow diagram** + +![Sequence diagram showing the interaction between an API Consumer and an API Producer (Helper*) for subscription management. The process includes creating a subscription, testing the notification endpoint, reading subscription information, and deleting the subscription.](dcd0b057e1c05cd391e93fbe2a67508f_img.jpg) + +``` + +sequenceDiagram + participant AC as API Consumer + participant HP as Helper* API Producer + AC->>HP: 1. POST .../subscriptions/XYZSubscriptions (XyzSubscriptionRequest) + Note over AC,HP: testing the notification endpoint + HP->>AC: 2. POST <<endpoint URI>> (initial notification) + AC->>HP: 3. 204 No Content + HP->>AC: 4. 201 Created (XyzSubscription) + Note over AC: opt [reading subscription information] + AC->>HP: 5. GET .../subscriptions/ + HP->>AC: 6. 200 OK (XyzSubscription[]) + AC->>HP: 7. GET .../subscriptions/{subscriptionId} + HP->>AC: 8. 200 OK (XyzSubscription) + Note over AC: API consumer does not need subscription anymore + AC->>HP: 9. DELETE .../subscriptions/{subscriptionId} + HP->>AC: 10. 204 No Content + +``` + +The "XyzSubscriptionRequest" payload includes information about the notification endpoints (callback URIs). + +Sequence diagram showing the interaction between an API Consumer and an API Producer (Helper\*) for subscription management. The process includes creating a subscription, testing the notification endpoint, reading subscription information, and deleting the subscription. + +\*Helper provided by cloud vendors + +Table 3: Resources and methods overview + +| Resource name | Resource URI | HTTP method or custom operation | Description | +|-------------------------|--------------------------------------------------------------------------------|---------------------------------|---------------------------------------------------| +| Subscriptions | {apiRoot}/ocloudNotifications/{apiMajorVersion}/subscriptions | POST | To create a new individual subscription resource. | +| | | GET | Get a list of subscription resources. | +| Individual subscription | {apiRoot}/ocloudNotifications/{apiMajorVersion}/subscriptions/{subscriptionId} | GET | Get Detail of individual subscription resources. | +| | | DELETE | Delete individual subscription resources. | + +### 4.1.1 Resources and HTTP Methods + +An Event Consumer (e.g. vDU or other CNF) will use a POST request to subscribe to receive notifications per its desirable resource. This resource is mapped to a data type/payload (see data model). + +The POST's payload will also include the notification endpoint (callback URI) for the API Producer to send the notifications back to the EC. + +The API Producer, in this case the Helper (see appendix A), will validate that the resource requested is offered by the cluster and available at the particular address. If the resource does not exist an error code will be sent to the client's EndpointURI. This will be followed by a sanity check of the requested notification endpoint and creating the resource if communication to the notification endpoint is successful. To reduce security concerns and lifecycle management burden the notification endpoint URI must be part of the same localhost, this is the localhost shared by the Event Consumer and Helper, with the assumption that they are located in the same POD or VM. + +### 4.1.2 Subscription resource definition + +The resource URI is: + +**{apiRoot}/ocloudNotifications/{apiMajorVersion}/subscriptions** + +The resource URI variables supported by the resource shall be defined as [Table 4](#) illustrates. + +**Table 4: Resource URI variables for this resource** + +| Name | Definition | +|-----------------|---------------------------------------------| +| apiRoot | described in clause 4.4.1 of 3GPP TS 29.501 | +| apiMajorVersion | v2 | + +#### 4.1.2.1 Subscription POST Method + +The POST method creates a subscription resource for the Event Consumer. As the result of successfully executing this method, a new subscription resource shall exist as defined in clause 1.2, and a variable value (*subscriptionId*) will be used in the representation of that resource. An initial status notification for the type of event (for example, PTP synchronization status) shall be triggered. The status describes the initial status of the producer resource when successfully executing this method as defined in clause 1.1.4, followed by any PTP status notifications (triggered if there is a change in PTP status). + +URI query parameters supported by the method shall be defined as [Table 5](#) illustrates. + +**Table 5: URI query parameters supported by a method on the resource** + +| Name | Data type | P | Cardinality | Description | Applicability | +|------|-----------|---|-------------|-------------|---------------| +| n/a | | | | | | + +Data structures supported by the request body of the POST method shall be specified as [Table 6](#) illustrates. + +**Table 6: Data structures supported by the request body on the resource** + +| Data type | P | Cardinality | Description | +|------------------|---|-------------|----------------------------------------------------------------------------------------------------------| +| Subscriptioninfo | M | 1 | The payload will include an event notification request, endpointUri and ResourceAddress. See note below. | + +**Note:** The *Subscriptioninfo* is defined in the subscription data model section + +Data structures supported by the response body of the method shall be specified as [Table 7](#) illustrates. + +**Table 7: Data structures supported by the response body on the resource** + +| | Data type | P | Cardinality | Response codes | Description | +|---------------|------------------|---|-------------|----------------|--------------------------------------------------------------------------------------------------| +| Response body | SubscriptionInfo | M | 1 | 201 | Shall be returned when the subscription resource is created successfully.<br><br>See note below. | +| | n/a | | | 400 | Bad request by the EC. For example, the endpoint URI does not include 'localhost'. | +| | n/a | | | 404 | Subscription resource is not available. For example, PTP is not supported by the node. | +| | n/a | | | 409 | The subscription resource already exists. | + +**Note:** The *SubscriptionInfo* is defined in the subscription data model section, see [Table 30](#) + +The following example shows a subscription request/response for /sync-state which would deliver notifications for the event.sync.sync-status.synchronization-state-change event only. + +##### **Example Create Subscription Resource: JSON request** + +``` +{ + { + "ResourceAddress": "/east-edge-10/Node3/sync/sync-status/sync-state/", + "EndpointUri "http://localhost:{port}/{path} + } +} +``` + +###### **Example Create Subscription Resource: JSON response** + +``` +{ + "SubscriptionId": "789be75d-7ac3-472e-bbbc-6d62878aad4a", + "ResourceAddress": "/east-edge-10/Node3/sync/sync-status/sync-state/", + "UriLocation": "http://localhost:8080/ocloudNotifications/v2/subscriptions/789be75d-7ac3-472e-bbbc-6d62878aad4a" +``` + +``` + +"EndpointUri ": "http://localhost:9090/publishers/{publisherid}" +} + +``` + +#### 4.1.2.2 Subscription GET Method + +The GET method queries the subscription object and its associated properties. As a result of a successful execution of this method a list of subscription object(s) and their associated properties will return by the API Producer. + +URI query parameters supported by the method shall be defined as [Table 8](#) illustrates. + +**Table 8: URI query parameters supported by a method on the resource** + +| Name | Data type | P | Cardinalit<br>y | Description | Applicability | +|------|-----------|---|-----------------|-------------|---------------| +| n/a | | | | | | + +Data structures supported by the response body of the method shall be specified as [Table 9](#) illustrates. + +**Table 9: Data structures supported by the response body on the resource** + +| | Data type | P | Cardinalit<br>y | Response<br>codes | Description | +|---------------|------------------|---|-----------------|-------------------|---------------------------------------------------------------------------------------------------------------| +| Response body | SubscriptionInfo | M | 0..N | 200 | Returns the subscription resources and their associated properties that already exist.<br><br>See note below. | +| | n/a | O | 0..1 | 400 | Bad request by the EC. For example, the endpoint URI does not include 'localhost'. | +| | | | | | | + +**Note:** The *SubscriptionInfo* is defined in the subscription data model section, see [Table 30](#) + +### 4.1.3 Individual subscription resource definition + +The resource URI is: + +**{apiRoot}/ocloudNotifications/{apiMajorVersion}/subscriptions/{subscriptionId}** + +The resource URI variables supported by the resource shall be defined as [Table 10](#) illustrates. + +**Table 10: Resource URI variables for this resource** + +| Name | Definition | +|-----------------|--------------------------------------------------------------------------------------------------------------------------------| +| apiRoot | described in clause 4.4.1 of 3GPP TS 29.501 | +| apiMajorVersion | v2 | +| subscriptionId | Identifier for subscription resource, created after a successful subscription. See table Data Model's <a href="#">table 30</a> | + +#### 4.1.3.1 Individual Subscription DELETE Method + +The DELETE method deletes an individual subscription resource object and its associated properties. As the result of a successful execution of this method a subscription resource object (the one associated with the *subscriptionId*) and its associated properties will be deleted by the API Producer. + +URI query parameters supported by the method shall be defined as [Table 11](#) illustrates. + +**Table 11: URI query parameters supported by a method on the resource** + +| Name | Data type | P | Cardinality | Description | Applicability | +|------|-----------|---|-------------|-------------|---------------| +| n/a | | | | | | + +Data structures supported by the request body of the DELETE method shall be specified as [Table 12](#) illustrates. + +**Table 12: Data structures supported by the request body on the resource** + +| Data type | P | Cardinality | Description | +|-----------|---|-------------|-------------| +| n/a | | | | + +Data structures supported by the response body of the method shall be specified as [Table 13](#) illustrates. + +**Table 13: Data structures supported by the response body on the resource** + +| | Data type | P | Cardinality | Response codes | Description | +|---------------|-----------|---|-------------|----------------|-------------------------------------------------------------------------------------------------| +| Response body | n/a | | | 204 | <b>DELETE</b><br>../subscriptions/{subscriptionId} deletes an individual subscription resource. | + +#### 4.1.3.2 Individual Subscription GET Method + +The GET method combined with the *subscriptionId* variable queries an individual subscription object and its associated properties. As a result of successful execution of this method an individual subscription resource object (the one associated with the *subscriptionId*) and its associated properties will return by the API Producer. + +URI query parameters supported by the method shall be defined as [Table 14](#) illustrates. + +**Table 14: URI query parameters supported by a method on the resource** + +| Name | Data type | P | Cardinality | Description | Applicability | +|------|-----------|---|-------------|-------------|---------------| +| n/a | | | | | | + +Data structures supported by the request body of the GET method shall be specified as [Table 15](#) illustrates. + +**Table 15: Data structures supported by the request body on the resource** + +| Data type | P | Cardinality | Description | +|-----------|---|-------------|-------------| +| n/a | | | | + +Data structures supported by the response body of the method shall be specified as [Table 16](#) illustrates. + +**Table 16: Data structures supported by the response body on the resource** + +| | Data type | P | Cardinality | Response codes | Description | +|---------------|------------------|---|-------------|----------------|------------------------------------------------------------------------------------------------| +| Response body | SubscriptionInfo | M | 1 | 200 | Returns the subscription resource object and its associated properties.<br><br>See note below. | +| | n/a | | | 404 | Subscription resources are not available (not created). | +| | | | | | | + +**Note:** The *SubscriptionInfo* is defined in the subscription Data Model section + +# Chapter 5 Status Notifications API Definition + +## 5.1 Description + +After a successful subscription (a subscription resource was created) the Event Consumer (e.g. vO-DU or other CNF) shall be able to receive event notifications from the subscribed resource. + +Events are sent by the Event Framework when a change of resource state occurs. The significance of the change of state is dependent upon the Event Producer service. An example for the PTP use case might be that a **synchronization-state-change** has occurred, i.e. FREERUN->LOCKED or LOCKED->HOLDOVER. + +The HTTP method for delivering the notification (push) to the EC shall be POST and the notification shall be sent to the endpoint reference provided by the EC client during the creation of the subscription resource (see [Table 17](#)). The payload body of the POST request shall contain the event payload (see event data model). + +[Figure 3](#) illustrates an intra-node (local notification) event delivery. In this example, the following occurs: + +1. The Event Framework determines that an event condition has occurred +2. The Event Consumer (vO-DU etc) has previously subscribed to the event type and the API Producer performs a POST to the EV (vO-DU etc) with the complete JSON event payload + +**Figure 3: Local Notification** + +![Sequence diagram illustrating local notification event delivery. The diagram is divided into two main contexts: 'Application Context' and 'Cloud Infrastructure'. In the 'Application Context', there is a 'Workload' containing an 'Event Consumer API Consumer' and an 'Event Consumer API Consumer'. In the 'Cloud Infrastructure', there is a 'Helper*' containing an 'API Producer' and an 'Event Framework o-cloud Implementation'. A precondition box states 'Precondition: API Consumer has subscribed to address previously'. An event occurs that matches the subscription. The 'Event Framework o-cloud Implementation' sends a POST request to the 'API Producer' with the event payload. The 'API Producer' then sends a POST request to the 'Event Consumer API Consumer' with the event payload. The 'Event Consumer API Consumer' responds with a 204 No Content status.](f00b403c073afb5136c65addbff6e99a_img.jpg) + +``` + +sequenceDiagram + box Application Context / Workload + participant EC as Event Consumer API Consumer + end + box Cloud Infrastructure + participant AP as Helper* API Producer + participant EF as Event Framework o-cloud Implementation + end + + Note over EC, EF: Precondition: API Consumer has subscribed to address previously + Note over EF: Event occurs that matches subscription + EF->>AP: + AP->>EC: 1. POST <<endpoint URI>> (XyzNotification) + EC->>AP: 2. 204 No Content + +``` + +\*Helper provided by cloud vendors + +Sequence diagram illustrating local notification event delivery. The diagram is divided into two main contexts: 'Application Context' and 'Cloud Infrastructure'. In the 'Application Context', there is a 'Workload' containing an 'Event Consumer API Consumer' and an 'Event Consumer API Consumer'. In the 'Cloud Infrastructure', there is a 'Helper\*' containing an 'API Producer' and an 'Event Framework o-cloud Implementation'. A precondition box states 'Precondition: API Consumer has subscribed to address previously'. An event occurs that matches the subscription. The 'Event Framework o-cloud Implementation' sends a POST request to the 'API Producer' with the event payload. The 'API Producer' then sends a POST request to the 'Event Consumer API Consumer' with the event payload. The 'Event Consumer API Consumer' responds with a 204 No Content status. + +**Table 17: API Producer Notification methods overview** + +| Resource URI | HTTP method or custom operation | Description | +|--------------------------------|---------------------------------|--------------------------------------------| +| http://localhost:{port}/{path} | POST | <b>Deliver notification to subscriber.</b> | +| | | Sanity check of the endpoint URI. | + +### 5.1.1 Event Consumer Notification Resource Definition + +The EC's endpoint URI is used by the API Producer (Helper) to deliver events to the Event Consumer (e.g. vO-DU or CNF). + +The EC's Endpoint URI<sup>2</sup> is: + +**http://localhost:{port}/{path}** + +The resource URI variables supported by the resource shall be defined as [Table 18](#) illustrates. + +**Table 18 Resource URI variables for this resource** + +| Name | Definition | +|------|---------------------------------------------------------| +| Port | The port of the endpoint URI provided by the subscriber | +| Path | The path of the endpoint URI provided by the subscriber | + +#### 5.1.1.1 Consumer Notification Delivery Method + +The HTTP method for the notification that corresponds to an explicit subscription shall be POST and the notification shall be sent to the endpoint reference provided during the creation of the subscription resource. The payload body of the POST request shall contain the event notification payload (see event data model). + +URI query parameters supported by the method shall be defined as [Table 19](#) illustrates. + +<sup>2</sup>Note: To reduce security concerns and lifecycle management burden the endpoint URI must be part of the same localhost, this is the localhost shared by the EC and API Producer in a POD or VM. + +**Table 19: URI query parameters supported by a method on the resource** + +| Name | Data Type | P | Cardinality | Description | Applicability | +|------|-----------|---|-------------|-------------|---------------| +| n/a | | | | | | + +Data structures supported by the request body of the POST method shall be specified as [Table 20](#) illustrates. + +**Table 20: Data structures supported by the request body on the resource** + +| Data type | P | Cardinality | Description | +|-----------|---|-------------|------------------------------------------------------------| +| Event | M | 1 | The payload will include event notification <sup>3</sup> . | + +Data structures supported by the response body of the method shall be specified as [Table 21](#) illustrates. + +**Table 21: Data structures supported by the response body on the resource** + +| | Data type | P | Cardinality | Response codes | Description | +|---------------|-----------|---|-------------|----------------|--------------------------------------| +| Response body | n/a | M | 1 | 204 | Success (notification was received). | +| | n/a | | | 400 | Bad request by the API Producer. | +| | n/a | | | 404 | Not found. | +| | n/a | | | 408 | Request timeout. | + +<sup>3</sup>Note: The *Notification* is defined in the notification Data Model section + +[Figure 4](#) shows an example event notification payload received by an Event Consumer. + +**Figure 4: Example Push Event Notification: request body in JSON** + +``` +{ + "specversion": "1.0", + "type": "event.synchronization-state-change", + "source": "/sync/sync-status/sync-state", + "id": "831e1650-001e-001b-66ab-eeb76e069631", + "time": "2021-03-05T20:59:59.998888999Z", + "data": { + "version": "1.0", + "values": [ + { + "type": "notification" + "ResourceAddress": "/east-edge-10/Node3/sync/sync-status/sync-state", + "value_type": "enumeration", + "value": "HOLDOVER" + } + ] + } +} +``` + +#### 5.1.1.2 Notification Sanity Check Method + +The Event Consumer POST request to create a subscription resource will trigger the initial delivery of producer status of the resource that will be sent to the endpoint URI provided by Event Consumer. The purpose is to confirm that the endpoint URI is valid and to send the initial status for the resource. If the validation fails, the subscription for the resource will not be created. + +URI query parameters supported by the method shall be defined as [Table 22](#) illustrates. + +**Table 22: URI query parameters supported by a method on the resource** + +| Name | Data type | P | Cardinality | Description | Applicability | +|------|-----------|---|-------------|-------------|---------------| +| n/a | | | | | | + +Data structures supported by the request body of the POST method shall be specified as [Table 23](#) illustrates. + +**Table 23: Data structures supported by the request body on the resource** + +| Data type | P | Cardinality | Description | +|-----------|---|-------------|--------------------------------------------------------------| +| Event | M | 1 | The payload will include event notification. See note below. | + +**Note:** The *Notification* is defined in the notification Data Model section + +Data structures supported by the response body of the method shall be specified as [Table 24](#) illustrates. + +**Table 24: Data structures supported by the response body on the resource** + +| | Data type | P | Cardinality | Response codes | Description | +|---------------|-----------|---|-------------|----------------|----------------------------------------------------------------------------------| +| Response body | n/a | M | 1 | 204 | The API Producer tests the endpoint URI before creating a subscription resource. | +| | n/a | O | 0..1 | 404 | URI not found. | +| | | | | | | + +# Chapter 6 Event Pull Status Notifications API Definition + +## 6.1 Description + +In addition to receiving event status notifications the Event Consumer (e.g. vO-DU or CNF) shall be able to pull event status notifications. This status notifications will be limited only to the node that the vO-DU resides on. + +[Figure 5](#) illustrates event pull status notifications and [Table 25](#) describes resources and methods. + +**Figure 5: Pull Notifications** + +![Sequence diagram illustrating the Event Pull Status Notifications API interaction between a Workload and a Helper.](9e85cb656004806d19c27b1419a85e9e_img.jpg) + +``` +sequenceDiagram + participant WC as Workload + participant H as Helper + Note over WC: Event Consumer / API Consumer + Note over H: API Producer + WC->>H: 1. GET PTP Status + H-->>WC: 2. 200 OK with event status content + Note over WC: Event Consumer / API Consumer + Note over H: API Producer +``` + +\*Helper is provided by cloud vendors + +Sequence diagram illustrating the Event Pull Status Notifications API interaction between a Workload and a Helper. + +Table 25: Pull Events Notifications methods overview + +| Resource name | Resource URI | HTTP method or custom operation | Description | +|---------------------------|--------------------------------------------------------------------------------|---------------------------------|-------------------------------------------| +| Pull Status Notifications | {apiRoot}/ocloudNotifications/{apiMajorVersion}/{ResourceAddress}/CurrentState | GET | Event Consumer pulls status notifications | + +### 6.1.1 Resources Pull Status Notification Definition + +The resource URI is: + +**{apiRoot}/ocloudNotifications/{apiMajorVersion}/{ResourceAddress}/CurrentState** + +The resource URI variables supported by the resource shall be defined as [Table 26](#) illustrates. + +Table 26: Resource URI variables for this resource + +| Name | Definition | +|-----------------|---------------------------------------------| +| apiRoot | described in clause 4.4.1 of 3GPP TS 29.501 | +| apiMajorVersion | v2 | +| ResourceAddress | see <a href="#">Table 1</a> | + +#### 6.1.1.1 Event Pull Status Notification GET Method + +The GET method combined with the *ResourceAddress* variable pulls the event status notifications. As a result of successful execution of this method the Event Consumer will receive the current event status notifications of the node that the Event Consumer resides on. + +URI query parameters supported by the method shall be defined as [Table 27](#) illustrates. + +Table 27: URI query parameters supported by a method on the resource + +| Name | Data type | P | Cardinality | Description | Applicability | +|------|-----------|---|-------------|-------------|---------------| +| n/a | | | | | | + +Data structures supported by the request body of the GET method shall be specified as [Table 28](#) illustrates. + +**Table 28: Data structures supported by the request body on the resource** + +| Data type | P | Cardinality | Description | +|-----------|---|-------------|-------------| +| n/a | | | | + +Data structures supported by the response body of the method shall be specified as [Table 29](#) illustrates. + +**Table 29: Data structures supported by the response body on the resource** + +| | Data type | P | Cardinality | Response codes | Description | +|---------------|-----------|---|-------------|----------------|-----------------------------------------------------------------------| +| Response body | Event | M | 1 | 200 | The payload includes event notification as defined in the Data Model. | +| | n/a | O | 0..1 | 404 | Event notification resource is not available on this node. | +| | | | | | | + +**Editor's note:** Currently the pull status operator returns the PTP Sync State event as defined in [PTP Sync-State](#). In future versions of this specification, status information can be expanded to other metrics / information pertinent to the operation of the system. + +# Chapter 7 Event Data Model + +## 7.1 Subscription Data Model + +This clause specifies the subscription data model supported by the API. + +### 7.1.1 Structured data types + +This clause defines the structures to be used in resource representations. + +#### 7.1.1.1 Type: SubscriptionInfo + +[Table 30](#) shows the data types used for subscription. + +**Table 30: Definition of type <SubscriptionInfo>** + +| Attribute name | Data type | P | Cardinality | Description | Applicability | +|-----------------|-----------|---|-------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------| +| SubscriptionId | string | M | 1 | Identifier for the created subscription resource.<br><br>The EC can ignore it in the POST body when creating a subscription resource (this will be sent to the client after the resource is created).<br><br><b>See note 1 below.</b> | | +| UriLocation | string | M | 1 | ../subscriptions/{subscriptionId}<br><br>The EC can ignore it in the POST body when creating a subscription resource (this will be sent to the client after the resource is created).<br><br><b>See note 1 below.</b> | | +| ResourceAddress | string | M | 1 | see <a href="#">Resource Addressing</a> | | +| EndpointUri | string | M | 1 | Endpoint URI (a.k.a callback URI), e.g. http://localhost:8080/resourcestatus/ptp<br><br><b>Please note that 'localhost' is mandatory and cannot be replaced by an IP or FQDN.</b> | | + +**Note 1:** The API Producer (Helper) shall ignore *SubscriptionId* and *UriLocation* if sent by the EC for creating subscription. + +## 7.2 Status Notifications Data Model + +This clause specifies the event Status Notification data model supported by the API. The current model supports JSON encoding of the [CloudEvents.io specification](#) [15] for the event payload. + +### 7.2.1 Structured data types + +This clause defines the structures to be used in notification representations. + +[Table 31](#) shows the data types used in the event data model JSON. + +**Table 31: Data Model Types** + +| CloudEvents | JSON | +|---------------|--------------------------------------------------------------------------------------------------------| +| Boolean | <a href="#">boolean</a> | +| Integer | <a href="#">number</a> , only the integer component optionally prefixed with a minus sign is permitted | +| String | <a href="#">string</a> | +| Binary | <a href="#">string</a> , Base64-encoded binary | +| URI | <a href="#">string</a> following <a href="#">RFC 3986</a> | +| URI-reference | <a href="#">string</a> following <a href="#">RFC 3986</a> | +| Timestamp | <a href="#">string</a> following <a href="#">RFC 3339</a> (ISO 8601) | + +### 7.2.2 Event Data Model + +**Table 32: Top-Level JSON Schema** + +| Property | Type | Constraint | Description | +|----------|--------|------------|-----------------------------------------------------------------------------------------------------------| +| id | String | rcv-only | Identifies the event. The Event Producer SHALL ensure that source + id is unique for each distinct event. | +| type | String | req | This attribute contains a value describing the type of event | + +| | | | | +|-------------|------------------------|----------|--------------------------------------------------------------------------------------------------------------------| +| | | | related to the originating occurrence. | +| source | URI-reference | rcv-only | Identifies the context in which an event happened. | +| specversion | String | rcv-only | The version of the CloudEvents specification which the event uses. This enables the interpretation of the context. | +| time | Timestamp | req | Time at which the event occurred. | +| data | String<br>(JSON array) | req | Array of JSON objects defining the information for the event | +| version | String | req | Version of the Notification API Schema generating the event.<br>'1.0' until a future revision. | +| values | String<br>(JSON array) | req | A json array of values defining the event. | + +| | | | | +|--|--|--|--| +| | | | | +|--|--|--|--| + +Table 35: Data Array Object Schema + +| Property | Type | Description | +|-----------------|------------------|---------------------------------------------------------------| +| data_type | String | Type of value object. ( <b>notification</b> <b>metric</b> ) | +| ResourceAddress | String<br>(path) | See Table 2 | +| value_type | Enumeration | The type format of the <i>value</i> property ( ) | +| value | String | String representation of value in value_type format | + +Table 34 shows an example event that contains Sync-State information. + +Table 34: Example Event -- Sync-State + +| | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <pre> { "id": "A234-1234-1234", "specversion": "1.0", "source": "/sync/sync-status/sync-state", "type": "event.sync.sync-status.synchronization-state-change", "time": "2021-03-05T20:59:00.999999999Z", "data": { </pre> | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +``` + +"version": "1.0", +"values": [ + { + "data_type": "notification", + "ResourceAddress": "/east-edge-10/Node3/sync/sync-status/sync-state", + "value_type": "enumeration", + "value": "HOLDOVER" + } +] +} + +``` + +### 7.2.3 Synchronization Event Specifications + +The following sections define the events related to synchronization events. + +Editor's Note: synchronization state change events are addressed first due to priority of the RAN use cases, the event distribution infrastructure and associated interfaces are not limited to one specific event category, and events from other subsystems will be added in the future versions of this document. + +Editor's Note: the present event set is aligned with / based on the WG4/WG5 YANG models; however, use of some other definitions such as composite clock modes in G.8275 (10/2020), Appendix VIII (or composite of the two approaches) \*may\* be more useful to convey the information in detail required to adequately specify the states in the cloud nodes context. + +#### 7.2.3.1 Synchronization State + +This notification abstracts the underlying technology that the node is using to synchronize itself. It provides the overall synchronization health of the node. This notification includes the health of the OS System Clock which is consumable by application(s). + +**Table 36: Synchronization State Notification** + +| Property | Value | Description | +|------------|-----------------------------------------------------|----------------------------------------------------------------------------| +| type | event.sync.sync-status.synchronization-state-change | Notification used to inform about the overall synchronization state change | +| source | /sync/sync-status/sync-state | Overall synchronization health of the node, including the OS System Clock | +| value_type | enumeration | | + +| | | | +|-------|----------|----------------------------------------------------------------------------------------------------------------| +| value | LOCKED | Equipment is in the locked mode, as defined in ITU-T G.810 | +| | HOLDOVER | Equipment clock is in holdover mode, as defined in ITU-T G.810 | +| | FREERUN | Equipment clock isn't locked to an input reference, and is not in the holdover mode, as defined in ITU-T G.810 | + +#### 7.2.3.2 + +#### 7.2.3.3 PTP Synchronization State + +**Table 37: Synchronization State Notification** + +| Property | Value | Description | +|------------|----------------------------------------|----------------------------------------------------------------------------------------------------------------| +| type | event.sync.ptp-status.ptp-state-change | Notification used to inform about ptp synchronization state change | +| source | /sync/ptp-status/lock-state | ptp-state-change notification is signalled from equipment at state change | +| value_type | enumeration | | +| value | LOCKED | Equipment is in the locked mode, as defined in ITU-T G.810 | +| | HOLDOVER | Equipment clock is in holdover mode, as defined in ITU-T G.810 | +| | FREERUN | Equipment clock isn't locked to an input reference, and is not in the holdover mode, as defined in ITU-T G.810 | + +#### 7.2.3.4 Void + +#### 7.2.3.5 Void + +#### 7.2.3.6 GNSS-Sync-State + +**Table 40: GNSS-Sync-State Notification** + +| Property | Value | Description | +|----------|------------------------------------------|---------------------------------------------------------------------| +| type | event.sync.gnss-status.gnss-state-change | Notification used to inform about gnss synchronization state change | +| source | /sync/gnss-status/gnss-sync- | gnss-state-change notification is signalled from equipment | + +| | | | +|------------|-----------------------|--------------------------------------------------| +| | status | at state change | +| value_type | enumeration | | +| value | SYNCHRONIZED | GNSS functionality is synchronized | +| | ACQUIRING-SYNC | GNSS functionality is acquiring sync | +| | ANTENNA-DISCONNECTED | GNSS functionality has its antenna disconnected | +| | BOOTING | GNSS functionality is booting | +| | ANTENNA-SHORT-CIRCUIT | GNSS functionality has an antenna short circuit | +| | FAILURE-MULTIPATH | GNSS Sync Failure - Multipath condition detected | +| | FAILURE-NOFIX | GNSS Sync Failure - Unknown | +| | FAILURE-LOW-SNR | GNSS Sync Failure - Low SNR condition detected | +| | FAILURE-PLL | GNSS Sync Failure - PLL is not functioning | + +#### 7.2.3.7 Void + +#### 7.2.3.8 OS Clock Sync-State + +**Table 37: OS clock Sync-State Notification** + +| Property | Value | Description | +|------------|---------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------| +| type | event.sync.sync-status.os-clock-sync-state-change | The object contains information related to a notification | +| source | /sync/sync-status/os-clock-sync-state | State of node OS clock synchronization is notified at state change | +| value_type | enumeration | | +| value | LOCKED | Operating System real-time clock is in the locked mode, node operating system clock is synchronized to traceable & valid time/phase source | +| | HOLDOVER | Operating System real-time clock is in holdover mode | +| | FREERUN | Operating System real-time clock isn't locked to an input reference, and is not in the holdover mode | + +#### 7.2.3.9 SyncE Lock-Status-Extended + +This notification is a SyncE Lock-state notification that provides detail about the sync PLL states. + +**Table 39: SyncE-Extended Lock-State Notification** + +| Property | Value | Description | +|------------|--------------------------------------------|------------------------------------------------------------------------------------------------------------------------------| +| type | event.sync.synce-status.synce-state-change | Notification used to inform about sync PLL synchronization state change, enhanced state information | +| source | /sync/synce-status/lock-state | sync PLL state change notification is signalled from equipment at state change, enhanced information | +| value_type | enumeration | | +| value | LOCKED | The integrated ordinary clock is synchronizing to the reference, recovered from SyncE signal | +| | HOLDOVER | The integrated ordinary clock is not synchronizing to the reference recovered from the SyncE signal, and is in holdover mode | +| | FREERUN | The integrated ordinary clock is not synchronizing to the reference, recovered from SyncE signal | + +#### 7.2.3.10 PTP Clock Class Change + +A PTP Clock Class change notification is generated when the PTP clock change attribute in the Announce message changes. + +**Table 36: PTP Clock class change Notification** + +| Property | Value | Description | +|------------|----------------------------------------------|--------------------------------------------------------------------------------| +| type | event.sync.ptp-status.ptp-clock-class-change | Notification used to inform about ptp clock class changes. | +| source | /sync/ptp-status/clock-class | ptp-clock-class-change notification is generated when the clock-class changes. | +| value_type | metric | | +| value | UInt8 | New clock class attribute | + +#### 7.2.3.11 SyncE Clock Quality Change + +A SyncE Clock Quality change notification is generated when the SyncE clock quality attribute in the ESMC message changes. + +**Table 43: SyncE Clock class change Notification** + +| Property | Value | Description | +|------------|----------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------| +| type | event.sync.synce-status.synce-clock-quality-change | Notification used to inform about changes in the clock quality of the primary SyncE signal advertised in ESMC packets | +| source | /sync/synce-status/clock-quality | synce-clock-quality-change notification is generated when the clock-quality changes. | +| value_type | metric | | +| value | Uint8 | New clock quality attribute | + +## 7.3 Appendix A + +### 7.3.1 Helper/Sidecar containers + +Reference: <https://kubernetes.io/blog/2015/06/the-distributed-system-toolkit-patterns/> + +Helper/Sidecar containers extend and enhance the "main" container, they take existing containers and make them better. + +As an example, consider a container that runs the Nginx web server. Add a different container that syncs the file system with a git repository, share the file system between the containers and one has built built Git push-to-deploy. And it has been done in a modular manner where the git synchronizer can be built by a different team, and can be reused across many different web servers (Apache, Python, Tomcat, etc). Because of this modularity, the git synchronizer may be written and tested only once and reused across numerous apps. + +![Diagram of an Application Pod showing a Web Server Container and a Log Saving Sidecar Container both connected to a shared Filesystem.](0074b9e45b1cc887b698c35894a127bf_img.jpg) + +``` + +graph TD + subgraph Application_Pod [Application Pod] + direction TB + subgraph Containers + direction LR + WSC[Web Server Container] + LSSC[Log Saving Sidecar Container] + end + FS[(Filesystem)] + WSC --> FS + LSSC --> FS + end + +``` + +Diagram of an Application Pod showing a Web Server Container and a Log Saving Sidecar Container both connected to a shared Filesystem. + +Helper/Sidecar value: + +- Interacts with the notification framework on behalf of the vO-DU +- Decouples the app logic from the notification framework, hence removes the burden of implementing a lot of code on the vO-DU and maintaining this code +- Single secure and reliable API endpoint since it is exposed over the localhost +- Eliminating the discovery of an external pod implementation + +# Annex (informative): Change History + +| Date | Revision | Author | Description | +|------------|----------|----------------------------------------|---------------------------------------------------------------------| +| 05/10/2021 | 00.00.01 | Aaron Smith (RH)<br>Udi Schwager (WRS) | Initial skeleton. | +| 07/22/2021 | 01.00.00 | Kaustubh Joshi (AT&T) | Approved for publication. | +| 03/28/2022 | 02.00.00 | Padma Sudarsan<br>(VMWare) | Incorporated 2 approved CRs (VMware, Wind River, RedHat, AltioStar) | +| 03/05/2022 | 02.00.01 | Udi Schwager (Wind River) | Ready for TSC review. | +| 07/25/2022 | 03.00.00 | Udi Schwager (Wind River) | Support for multiple event producers | +| 03/15/2024 | 03.00.01 | Udi Schwager (Wind River) | Incorporated Qualcomm CR | +| 03/21/2024 | 03.00.03 | Udi Schwager (Wind River) | Editorial updates | \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/06f39761d27a53791ce70f4401d7f0f0_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/06f39761d27a53791ce70f4401d7f0f0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d796f3edb201d9986e57ec55206303411e0cbc8 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/06f39761d27a53791ce70f4401d7f0f0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b64f707d9abec272e3cdabd94037aa71dba3b53e7741b162f74567d749ed9b4c +size 34519 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/0c33c343cc672455889a92c224d6470d_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/0c33c343cc672455889a92c224d6470d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d51a4e23db6f1017e35a922429fca516d60f0c1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/0c33c343cc672455889a92c224d6470d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:65e3cda1fa0e627fe775b1f863f4ba28c2a91ab60cb3b25104c35ce434502e39 +size 4500 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/0d361550821fc22b70c4e3d673750d27_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/0d361550821fc22b70c4e3d673750d27_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a94714ee97952b44d3119d02046836673a707734 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/0d361550821fc22b70c4e3d673750d27_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3d6588d38b0d3a6e4c2899a66348bd465dd111e0b2eebdaae6884fb36204ec1a +size 147494 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/2450ddaf17b9b921561d791a1e8cbea4_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/2450ddaf17b9b921561d791a1e8cbea4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2b315d84297837d1fbab576af7b6942279df9b6a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/2450ddaf17b9b921561d791a1e8cbea4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:58a6b27f2ce300375aa6a93b75d183478e1446e8a985ea947ba8a9e1f85060d2 +size 4530 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/27ff94a8bfab0df3e1df3e3455843da5_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/27ff94a8bfab0df3e1df3e3455843da5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..27ab85b2978a157a533b4005fc8090abe2249cc5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/27ff94a8bfab0df3e1df3e3455843da5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:790fa3ff265c56348a638a91e4ec2dfaf309335c9a70ffe2f892afe5c77a995b +size 37426 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/39de7f668885e7b8809267f54f614880_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/39de7f668885e7b8809267f54f614880_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b1d7397492383d22034bb528172d5fac25bbb445 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/39de7f668885e7b8809267f54f614880_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aab4538d061e8739f2dc9287f6e83ada04877c38622954edf19ae981273b0c90 +size 4494 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/3e8ede1da0b9ddf3d1b03f0a72fc9b52_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/3e8ede1da0b9ddf3d1b03f0a72fc9b52_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8957b9ac381c9dc0b688ace63936c6184b398427 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/3e8ede1da0b9ddf3d1b03f0a72fc9b52_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0d0a3584992bcf4bcaac56ffa4b03c5ab72c1a5462d2b693d304773db65fcc82 +size 136612 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/3ed9cc2f8184af31162f75eef7481b60_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/3ed9cc2f8184af31162f75eef7481b60_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a163a69efa8a73c1b16452290d16d5b8e1580ef3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/3ed9cc2f8184af31162f75eef7481b60_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:610d1efd4ec31308e181577dc18bea50d7ea0e0a314742898df2cee181fbc4fa +size 4551 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/5605c84e281864dd7571b91ee16f62d3_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/5605c84e281864dd7571b91ee16f62d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2ec412af445bb880ace359e796f2c8a15e7738f1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/5605c84e281864dd7571b91ee16f62d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8ae596f94948745f0a4f22ee1f301145dd654a3d597e06c11b428e82e1670dae +size 4551 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/5a6294a26094a4de24ef636802a5b8ce_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/5a6294a26094a4de24ef636802a5b8ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..265408f1d130817c50a24bc2d100a81e45786ac7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/5a6294a26094a4de24ef636802a5b8ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ce83340f2bd636fc41ecbd83f01c7f43c79e5a6e0fe7f973c9b3a341dac6b33 +size 4495 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/627727740e2c0ac51fc68fe16917aac6_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/627727740e2c0ac51fc68fe16917aac6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..92d27ee55b83f9ccec60a37fcf6a95e199d64d6c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/627727740e2c0ac51fc68fe16917aac6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2312360e34fc4a340e90f11be0be455145a1ef170498991548901caf35196790 +size 4522 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/6998e8f2e9a203955d81c8ebbd570e55_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/6998e8f2e9a203955d81c8ebbd570e55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..040bff082765b416400d0486644cf62df290ce39 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/6998e8f2e9a203955d81c8ebbd570e55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2a81f4ba14b71ab8680f1eab388e6eb42152402d827b2710500d799ca57c980c +size 4683 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/69acca918127511c2bfdb669a146ae39_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/69acca918127511c2bfdb669a146ae39_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12b07f6340f65ebdfd71010e13b81d947f70b6e4 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/69acca918127511c2bfdb669a146ae39_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bfaa6568307f783afe236e80c2c92160bdac62c50e49134078d8ba0b4a44b8e2 +size 4503 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/9a40f8bd35f7408224d1ee1180ae6d2e_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/9a40f8bd35f7408224d1ee1180ae6d2e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a3411ad25b2f0d27b932ace9f4ab0ac20e2abb89 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/9a40f8bd35f7408224d1ee1180ae6d2e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1d88e6d82cd4e5126fdff72d238047bbc2727eca708cbf1645a70cc4ce9fd49c +size 240579 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/aac75f1e979de38733ed04897b9b1a47_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/aac75f1e979de38733ed04897b9b1a47_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dcfb81811cf0703f482506af088e9d6800cc3b84 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/aac75f1e979de38733ed04897b9b1a47_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f403c21bd52317d12c8badff647339054a7485f5675d71e191286efdb1a0a859 +size 132833 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/ac289ca022e0e1f7dcba6c253463cecc_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/ac289ca022e0e1f7dcba6c253463cecc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5f52ddf3ddbae80afd7ea89dda9dc3880f31f805 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/ac289ca022e0e1f7dcba6c253463cecc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8010fd4763a1bd9f3ee0aea56cb22447a2a28a6dc241cb935e406366da4c0f64 +size 4544 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/d6a5ae5c2bcc787cd208a0f2b7fcb86d_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/d6a5ae5c2bcc787cd208a0f2b7fcb86d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a1c6bdfe42511c1899b560f5c5f9f1ba68a74116 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/d6a5ae5c2bcc787cd208a0f2b7fcb86d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:237d08d5b1331c724e31a70329bb83bbfe7e295aae6206dd4e25e9f4e107da02 +size 4444 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/d83e9d62dd9a1f079897d2bc11e324d3_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/d83e9d62dd9a1f079897d2bc11e324d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b53a5ac67f18ab0b995403b5f3742f4812b9f194 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/d83e9d62dd9a1f079897d2bc11e324d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fc2d8a7b62e737d6b07914cd6dbf2d9dd59c84d6b04c8b35e9d4ab9edbc5bd6c +size 63990 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/d9d5c6da4ffd680a7143b0d872e75305_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/d9d5c6da4ffd680a7143b0d872e75305_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..22f0f20ab58a3ac9c46ed4438d3efc14318178bb --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/d9d5c6da4ffd680a7143b0d872e75305_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:38f346ff1463d4161edcf87b3c3399aad2858169cf8e1ed8014c0e5db701b1fa +size 4440 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/e28c6e704187c04649330317a7bc879a_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/e28c6e704187c04649330317a7bc879a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4d19f68b0f14ca5c4624d387346b192683b0c84b --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/e28c6e704187c04649330317a7bc879a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:961edf29d7101c36a5633a34cb07127ddc8d42543983c969931296b3e82c0b66 +size 4449 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/fcfd0f91ae8a590d2477233da8112ecd_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/fcfd0f91ae8a590d2477233da8112ecd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b7a22be3bbf4634a01e74146584a5ce6c7cb38ea --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/fcfd0f91ae8a590d2477233da8112ecd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2980e7a8abce05796398f9a86319e5275baa01712b04436486f0cded3df672b7 +size 4549 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/fdfdf06f3c0d9e960d530795927d7054_img.jpg b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/fdfdf06f3c0d9e960d530795927d7054_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db5a189b78401c63d1bd1ddd787d66e4f9576677 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/fdfdf06f3c0d9e960d530795927d7054_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:532cd8f1a015917b501b4bad7c07bb3d4143639b6a3d22f6986133d6bff430ad +size 47573 diff --git a/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/raw.md b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..d519def3036f0bcc4445b534b5bd560c40c4ce24 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O-Cloud-ES-v02.00/raw.md @@ -0,0 +1,989 @@ + + +# --- **O-RAN Working Group 6 (Cloudification and Orchestration Workgroup)****Study on O-Cloud Energy Savings** --- + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# Contents + +| | | +|-----------------------------------------------------------------------------------|----| +| Contents ..... | 2 | +| List of figures ..... | 4 | +| List of tables ..... | 4 | +| Foreword ..... | 5 | +| Modal verbs terminology ..... | 5 | +| Executive summary ..... | 5 | +| Introduction ..... | 5 | +| 1 Scope ..... | 6 | +| 2 References ..... | 6 | +| 2.1 Informative references ..... | 6 | +| 3 Definition of terms, symbols and abbreviations ..... | 7 | +| 3.1 Terms ..... | 7 | +| 3.2 Symbols ..... | 7 | +| 3.3 Abbreviations ..... | 7 | +| 4 O-Cloud Energy Savings background, concepts, and assumptions ..... | 7 | +| 4.1 O-Cloud Energy Savings Objectives ..... | 7 | +| 4.2 O-Cloud Energy Savings concept and assumptions ..... | 8 | +| 4.2.1 Overview ..... | 8 | +| 4.2.2 O-Cloud Resource Energy Management ..... | 8 | +| 4.3 Architecture options to achieve energy savings optimisation ..... | 11 | +| 4.3.1 Overview ..... | 11 | +| 4.3.2 Energy Saving Policy applied via Kubernetes API ..... | 11 | +| 4.3.3 Energy Saving Policy applied by NF Deployment ..... | 12 | +| 5 Energy Savings Use Cases ..... | 13 | +| 5.1 Use Case 1: O-Cloud Node Shutdown in Idle Mode ..... | 13 | +| 5.1.1 Overview ..... | 13 | +| 5.1.2 Description and UML Diagrams ..... | 14 | +| 5.1.3 Potential Requirements ..... | 15 | +| 5.2 Use Case 2: CPU core frequency and pinning configuration change by SMO ..... | 15 | +| 5.2.1 Overview ..... | 15 | +| 5.2.2 Description and UML Diagrams ..... | 17 | +| 5.2.3 Potential Requirements ..... | 18 | +| 5.3 Use Case 3: C-state usage for NF Deployment ..... | 19 | +| 5.3.1 Overview ..... | 19 | +| 5.3.2 C-state Configuration for NF Deployments ..... | 19 | +| 5.3.3 Potential Requirements ..... | 20 | +| 5.4 Use Case 4: O-Cloud Node Cluster Mode Selection ..... | 20 | +| 5.4.1 Overview ..... | 20 | +| 5.4.2 Description and UML Diagrams ..... | 21 | +| 5.4.3 Potential Requirements ..... | 22 | +| 6 Power Consumption, Energy Consumption and Efficiency Measurement and KPIs ..... | 22 | +| 6.1 Overview ..... | 22 | +| 6.2 Power, energy consumption metrics of Infrastructure ..... | 22 | +| 6.2.1 Overview ..... | 23 | +| 6.2.2 Measurement and KPI Definition ..... | 23 | +| 6.3 Power, Energy Consumption Metrics of Containers ..... | 24 | +| 6.3.1 Overview ..... | 24 | +| 6.3.2 Measurement and KPI Definition ..... | 24 | +| 6.4 Power, energy consumption metrics of NF deployment and Cloudified NF ..... | 25 | +| 6.4.1 Overview ..... | 25 | +| 6.4.2 Measurement and KPI Definition ..... | 25 | + +| | | | +|----------------------------------|------------------------------------------|-----| +| 6.5 | Energy efficiency of Cloudified NF ..... | 26 | +| 6.5.1 | Overview ..... | 27 | +| 6.5.2 | Measurement and KPI Definition ..... | 27 | +| 7 | Recommendations ..... | 27 | +| 8 | Conclusions ..... | 27 | +| Annex A (Informative): ..... | | 28 | +| A.1 Power Modeling Example ..... | | 28 | +| Revision history ..... | | 30 | +| History ..... | | 322 | + +# List of figures + +| | | +|---------------------------------------------------------------------------------|----| +| Figure 4.2-1 : Key Components Involved in/with an O-Cloud ..... | 9 | +| Figure 4.2-2 : C-State example ..... | 10 | +| Figure 4.3-1 : Energy Saving Policy applied via Kubernetes® API ..... | 12 | +| Figure 4.3-2 : Energy Saving Policy applied by NF Deployment ..... | 13 | +| Figure 5.1-1 : O-Cloud Node Shutdown in Idle Mode ..... | 15 | +| Figure 5.2-1 : CPU core frequency and pinning configuration change by SMO ..... | 18 | +| Figure 5.3-1 : C-state usage for NF Deployment ..... | 20 | +| Figure 5.4-1 : O-Cloud Node Cluster Mode selection ..... | 22 | + +# List of tables + +| | | +|---------------------------------------------------------------------------------------|----| +| Table 5.1-1 : O-Cloud Node Shutdown in Idle Mode Sequence Description ..... | 14 | +| Table 5.2-1 : CPU core frequency and pinning configuration Sequence Description ..... | 17 | +| Table 5.4-1 : Examples of Modes and their Description ..... | 21 | +| Table 5.4-2 : O-Cloud Node Cluster Mode selection Sequence Description ..... | 21 | +| Table 6.2-1 : O-Cloud Resource Infrastructure Power Consumption Metrics ..... | 23 | +| Table 6.2-2 : O-Cloud Node Resource Energy Consumption ..... | 24 | +| Table 6.3-1 : Container Energy Consumption ..... | 24 | +| Table 6.3-2 : Container Resource Utilization ..... | 25 | +| Table 6.4-1 : Estimated NF Deployment Power Consumption ..... | 26 | +| Table 6.4-2 : Estimated NF Deployment Energy Consumption ..... | 26 | +| Table 6.4-3 Estimated Cloudified NF Power Consumption ..... | 26 | +| Table 6.4-4 Estimated Cloudified NF Energy Consumption ..... | 26 | +| Table 6.5-1 Types of Energy Efficiency Measures ..... | 27 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +--- + +## Modal verbs terminology + +In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and "cannot" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Executive summary + +Open RAN energy management is a key sustainability objective for all mobile operators around the world. This could help Open RAN technology to scale for commercial deployments and speed up O-RAN technology development. Telecoms industry requires a standardized approach not only for achieving energy saving, but also for evaluating, testing, measuring, and monitoring energy consumption of Open RAN Cloud deployments. This Technical Report (TR) analyses some energy techniques that can be utilized within the O-Cloud to achieve promising reduction in Open RAN Cloud deployment power consumption. + +--- + +# Introduction + +Energy consumption of RAN has become a key part of the operators' OPEX. The energy cost on RAN is expected to continue to grow with increased adoption of 5G technology enablers such as Massive MIMO and B5G/6G. Energy efficiency is therefore essential and crucial for Open RAN technology to scale for commercial deployments. Telecoms industry requires a standardized approach not only for achieving energy saving, but also for evaluating, testing, measuring, and monitoring energy consumption of dis-aggregated Multi-vendor Open RAN Cloud deployments. + +This technical report focuses on the power management techniques that could be implemented within the O-Cloud to reduce energy consumption. O-RAN relies on the O-Cloud to deploy RAN Network functions. Therefore, energy savings using power management techniques within the O-Cloud could enable significant reduction of Open RAN power consumption. This TR further aims to provide potential concepts, requirements, user stories and use cases optimizing the O-Cloud resources used by the RAN application, and thus accelerating innovation to introduce energy efficiency in OpenRAN deployments. + +In O-RAN architecture., the SMO collects data from the deployed applications (O1) along with O-Cloud data related to the Cloud infrastructure and NF Deployments (O2 IMS and DMS). These data can be used to create policies for energy savings and trigger the energy saving activities. In the following sections different power management techniques are reviewed, which can be used to reduce the O-Cloud energy consumption and derive recommendations. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document reports about power management techniques that could be implemented within the O-Cloud to reduce energy consumption and achieve energy savings. + +# --- 2 References + +## 2.1 Informative references + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [1] O-RAN WG6, Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN - v06.00, Technical Report. See <https://www.o-ran.org/specifications>. +- [2] 3GPP TS 28.554: “Technical Specification Group Services and System Aspects; Management and orchestration; 5G end to end Key Performance Indicators (KPI)”, Release 17, March 2023 +- [3] Intel® Technology Guide: “Power Management - Technology Overview”. See <https://networkbuilders.intel.com/solutionslibrary/power-management-technology-overview-technology-guide> +- [4] O-RAN WG1, Decoupled SMO Architecture - v02.00, Technical Report. See <https://www.o-ran.org/specifications>. +- [5] Intel® Technology Guide: “Power Management - User Wait Instructions Power Saving for DPDK PMD Polling Workloads”. See <https://networkbuilders.intel.com/solutionslibrary/power-management-user-wait-instructions-power-saving-for-dpdk-pmd-polling-workloads-technology-guide> +- [6] O-RAN WG6, O2 Interface General Aspects and Principles - v06.00, Technical Specification. See <https://www.o-ran.org/specifications> +- [7] O-RAN WG6, O2IMS Interface Specification - v04.00, Technical Specification. See <https://www.o-ran.org/specifications>. +- [8] Redfish Resource and Schema Guide. DMTF Redfish DSP2046 (2022.2): "Redfish Resource and Schema Guide," published 2022-09-15. +- [9] DMTF Redfish DSP2051: "Redfish Telemetry White Paper," published 2020-03-27. +- [10] ETSI GR NFV-EVE 021 (V5.1.1): “Network Functions Virtualisation (NFV) Release 5; Evolution and Ecosystem; Report on energy efficiency aspects for NFV”. +- [11] 3GPP TS 28.554: “Technical Specification Group Services and System Aspects; Management and orchestration; 5G end to end Key Performance Indicators (KPI)”, Release 17, March 2023 + +- [12] ETSI ES 203 228: “Environmental Engineering (EE); Assessment of mobile network energy efficiency”, v1.3.1 +- [13] 3GPP TS 28.552: “Technical Specification Group Services and System Aspects; Management and orchestration; 5G performance measurements”, Release 18, March 2023 +- [14] O-RAN WG6, O2dms Interface Specification: Profile based on ETSI NFV Protocol and Data Models - v06.00, Technical Specification. See <https://www.o-ran.org/specifications>. +- [15] O-RAN WG6, O2dms Interface Specification: Kubernetes Native API Profile for Containerized NFs v04.00, Technical Specification. See <https://www.o-ran.org/specifications>. +- [16] Kubernetes Efficient Power Level Exporter (Kepler): <https://sustainable-computing.io/> +- [17] Kepler Github Repo: <https://github.com/sustainable-computing-io/kepler> +- [18] Kepler Power Model: [https://sustainable-computing.io/design/power\\_model/](https://sustainable-computing.io/design/power_model/) +- [19] O-RAN WG1, Network Energy Saving Use Cases Technical Report-v02.00, Technical Report, See <https://www.o-ran.org/specifications>. + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in O-RAN.WG6.CADS [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in O-RAN.WG6.CADS [1]. + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +| | | +|----------------------------------------|------------------------------------------------------------------------| +| $P_{NF\text{ Deployment, estimated}}$ | Estimated power consumption of a NF Deployment running in the O-Cloud | +| $EC_{NF\text{ Deployment, estimated}}$ | Estimated energy consumption of a NF Deployment running in the O-Cloud | +| $P_{cloudifiedNF, estimated}$ | Estimated power consumption of a Cloudified NF | +| $EC_{cloudifiedNF, estimated}$ | Estimated energy consumption of a Cloudified NF | +| $EE_{cloudifiedNF}$ | Energy efficiency of a Cloudified NF | + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in O-RAN.WG6.CADS [1], 3GPP TS 28.554 [2], and O-RAN.WG1.NESUC [19] apply. + +# 4 O-Cloud Energy Savings background, concepts, and assumptions + +## 4.1 O-Cloud Energy Savings Objectives + +The present Technical Report is part of the WG6 UCTG Network Energy Saving pre-normative phase. The objectives of the pre-normative phase are as follows: + +- Study O-Cloud Energy savings Use cases including potential requirements, key issues, and benefits of proposed solutions. +- Study KPIs and focus on specifying O-Cloud hardware and/or software measurement and telemetry for O-Cloud energy saving, including: + +- Study if new measurements and telemetry data for O-Cloud energy saving would be collected from the O-Cloud and describe corresponding measurements and telemetry data in appropriate specifications. +- Study potential energy saving relevant measurements and telemetry for O-Cloud resources, resource pools, O-Cloud node groups and O-Cloud nodes. +- Study potential impact and enhancements to O-RAN interfaces such as O2 IMS/DMS, O1, and R1. + +Algorithms discussed and analysed as part of the O-Cloud Energy Savings pre-normative phase will be examples only and will not be part of any specification as outcome of this pre-normative phase or subsequent work items. + +For each use case solution proposal, the detailed objectives are: + +- Review, evaluate applicability of, and select from existing deployment alternatives and AI/ML deployment scenarios and document respective findings: + - Evaluate energy savings gains based on a O-Cloud energy consumption model. + - Study on a per sub-use case basis potential impact and enhancements on O-RAN interfaces (e.g. O1, O2, R) in terms of required input data and output configuration data. + - Review existing counters, KPIs, and data models as specified/studied in other organizations, such as 3GPP. + - Study potential enhancements on existing counters, KPIs, and data models or define new counters, KPIs, and data models of all involved O-RAN entities. + +## 4.2 O-Cloud Energy Savings concept and assumptions + +### 4.2.1 Overview + +With the move towards commercial off-the-shelf (COTS) servers for O-Cloud implementations, O-RAN vendors are free to leverage the many existing technologies in COTS servers and clouds for energy savings. It is assumed that some of these technologies may be used in O-Clouds. This section will give a brief background on the different technologies available in modern General-Purpose servers see [3]. + +### 4.2.2 O-Cloud Resource Energy Management + +#### 4.2.2.1 Overview + +An O-Cloud Resource is defined in an O-Cloud infrastructure as one that may be provisioned and managed through an abstraction [1]. O-Cloud infrastructure has two kinds of resources: physical and logical resources. A physical resource is defined as a kind of resource that has a manifestation in the real world. A logical resource is defined as a kind of resource that uses several physical resources, or a portion of physical resources, or several software entities. + +For example, some kinds of physical resources could be servers, switches, and storage units. + +For example, some kinds of logical resources are OpenStack and K8s clusters. + +Various Energy Management methods can be applied on O-Cloud Resources to reduce the power consumption in O-Cloud. Some of the examples are given below. + +**CPU Energy Management** - Applying various methods to adjust the CPU frequency and Voltage to reduce the CPU energy consumption. + +**Clock Gating** - Disabling a portion of a circuit in CPU that results in lower power consumption. + +**Adaptive Link Rate** - With this technology, the data rate for a network link can be adjusted during the period of low network traffic. + +**Idle States and Performance states** - O-Cloud Resources can have certain idle states/performance states enabled during the period of low utilization. + +![Figure 4.2-1: Key Components Involved in/with an O-Cloud. The diagram illustrates the architecture of an O-Cloud, showing the interaction between the Service Management & Orchestration Framework and the O-Cloud itself. The O-Cloud is divided into two main sections: O-Cloud and O-Cloud Site. The O-Cloud section includes Infrastructure Management Services (Logical & Distributed) [1], Deployment Management Services (Logical & Distributed) [1..n], and the Deployment Plane (Logical). The Deployment Plane (Logical) is further divided into NF Deployment, NF Deployment, and NF Part Deployment. The O-Cloud Site section includes Resource Pools, Site Network Fabric, and Gateway. The diagram also shows the interaction between the O-Cloud and the O-Cloud Site, with the O-Cloud Site being distributed across multiple locations.](aac75f1e979de38733ed04897b9b1a47_img.jpg) + +Figure 4.2-1: Key Components Involved in/with an O-Cloud. The diagram illustrates the architecture of an O-Cloud, showing the interaction between the Service Management & Orchestration Framework and the O-Cloud itself. The O-Cloud is divided into two main sections: O-Cloud and O-Cloud Site. The O-Cloud section includes Infrastructure Management Services (Logical & Distributed) [1], Deployment Management Services (Logical & Distributed) [1..n], and the Deployment Plane (Logical). The Deployment Plane (Logical) is further divided into NF Deployment, NF Deployment, and NF Part Deployment. The O-Cloud Site section includes Resource Pools, Site Network Fabric, and Gateway. The diagram also shows the interaction between the O-Cloud and the O-Cloud Site, with the O-Cloud Site being distributed across multiple locations. + +Figure 4.2-1: Key Components Involved in/with an O-Cloud + +#### 4.2.2.2 CPU Energy Management + +##### 4.2.2.2.1 Overview + +Energy efficiency and management in O-Cloud can be accomplished by CPU Energy Management. CPU energy consumption can be managed by introducing different levels of energy consumption with CPU frequency and voltage scaling. CPU energy savings can be achieved by modifying the power states of CPU or other configurable methods for CPU energy management. + +##### 4.2.2.2.2 Direct Method + +The predictable and linear method to scale the CPU frequency and voltage: + +- Sleep states (C-States) - These states are used to alter energy usage from CPU systems in a power management strategy employed independently or together with P-State. +- Performance States (P-States) - These states are used to alter energy usage from CPU systems in a power management strategy employed together with C-State. +- Thermal States (T-States) – These states are used for thermal management to reduce the heat and power of a CPU by frequency and voltage scaling. + +C-states are power states that a CPU can use to reduce power consumption on a per-core level, or on a CPU package level, by powering down portions of the core, package, or both. Disabling portions of the core allows for large power savings but prevents the core from executing instructions. C-states can be used to move individual cores or the full CPU Package to an idle state, reducing the power consumption of the server. Figure 4.2-2 below shows an example of some of the different C-state supported. Note that other C-states may be supported and have different characteristics. + +![Figure 4.2-2: C-State example. A diagram comparing four C-states: C0, C1, C1E, and C6. The rows represent different system components: Core VCC*, L1/L2 Cache, L3 Cache, Wake Time*, and Idle Power*. C0 shows all components active. C1 shows Core VCC and Idle Power active, while L1/L2 and L3 caches are flushed. C1E shows Core VCC and Idle Power active, with L1/L2 and L3 caches flushed. C6 shows Core VCC and Idle Power active, with L1/L2 and L3 caches flushed. Wake Time* is shown as a clock icon for C0, C1, and C1E, and as a clock icon with a checkmark for C6. A note at the bottom left states '*Rough Approximation'.](06f39761d27a53791ce70f4401d7f0f0_img.jpg) + +| | C0 | C1 | C1E | C6 | +|-------------|--------|---------|---------|---------| +| Core VCC* | Active | Active | Active | Off | +| L1/L2 Cache | Active | Flushed | Flushed | Flushed | +| L3 Cache | Active | Flushed | Flushed | Flushed | +| Wake Time* | Active | Active | Active | Active | +| Idle Power* | Active | Active | Active | Active | + +\*Rough Approximation + +Figure 4.2-2: C-State example. A diagram comparing four C-states: C0, C1, C1E, and C6. The rows represent different system components: Core VCC\*, L1/L2 Cache, L3 Cache, Wake Time\*, and Idle Power\*. C0 shows all components active. C1 shows Core VCC and Idle Power active, while L1/L2 and L3 caches are flushed. C1E shows Core VCC and Idle Power active, with L1/L2 and L3 caches flushed. C6 shows Core VCC and Idle Power active, with L1/L2 and L3 caches flushed. Wake Time\* is shown as a clock icon for C0, C1, and C1E, and as a clock icon with a checkmark for C6. A note at the bottom left states '\*Rough Approximation'. + +Figure 4.2-2: C-State example + +C-states can be managed or controlled in several different methods + +- **Hardware:** In certain configurations, the Power Control Unit (PCU) in the CPU is responsible for autonomously coordinating core and package C-states while BIOS configuration allows you to limit the C-states available to the platform, ensuring it never goes below your required C-state. Alternatively, Linux Kernel drivers (such as `acpi_idle` or `intel_idle`) and the Linux Kernel scheduler govern C-states. +- **Operating System:** Core C-states are controlled by the OS as defined by the ACPI Specification. The OS can tell the threads in a core to go to a particular C-state using the `MWAIT` and `MONITOR` instruction for example. In supported CPUs, application software can use the `waitpkg` instructions to request power-optimised states C0.1 and C0.2 for example. +- **Application:** Software techniques can be used to influence kernel control of C-states for example a SW thread that sleeps using standard Linux system, such as `usleep()` can help the Linux Kernel to sleep the core if there is no other work to be scheduled on that core. In supported CPUs, application software can use the user mode `waitpkg` instructions to directly request power-optimised states C0.1 and C0.2 for example [5]. + +A Performance State (P-state) is an operating point where a CPU core is operating at a specific frequency and voltage while executing instructions. As the core moves to lower P-states, the frequency and associated voltage drops resulting in reduced power consumption and performance. The Advanced Configuration and Power Interface (ACPI) defines the performance states that are exposed to system software. Software interfaces allow P-states to be controlled per core. P-states can be used to dynamically reduce frequency per core, reducing the power consumption of the server. + +P-states may be managed or controlled in several different methods + +- **Hardware:** Hardware-Controlled Performance States (HWP) give the option to pass P-state control to the hardware, allowing it to make much faster and finer adjustments to the frequency and voltage, based on each core's load and OS hints. Without HWP, the OS can directly request P-states through the Linux Kernel drivers (such as `acpi_cpufreq` driver, `intel_pstate` driver). +- **Operating System:** P-states can be managed from user space via the Linux Kernel system file system, such as `"sysfs"`. By default, the P-states have a management routine known as a governor that decides how to control the frequency in response to the workload. +- **Application:** As demonstrated by the DPDK Power Management library a user space application can save power by dynamically adjusting CPU frequency. The user space application can request a specific P-state configuration from the kernel. + +NOTE: Linux® is the registered trademark of Linux Torvalds in the U.S. and other countries. + +##### 4.2.2.2.3 Indirect Method + +These are the methods which are complex, have dependencies and do not follow the cause-and-effect pattern. By applying these methods, the energy consumption of the CPU can be reduced. + +- CPU affinity – Assigning specific processes or threads to a core can help improve NF performance which can reduce the CPU energy consumption. +- Consuming least number of cores with technology such as simultaneous multithreading allows other cores to remain in low power or idle state which can reduce energy consumption. +- Scheduling – Scheduling of threads and processes in an energy efficient manner + +#### 4.2.2.3 Modes and Policies for Energy Savings in O-Cloud + +A Mode refers to a setting which can contain a set of different policies and/or configurations, that aims to improve certain characteristics of a system, e.g., for energy efficiency or performance. Some of the Modes can be used to save the energy of an O-Cloud by representing different levels of energy consumption. + +As defined in WG1.Decoupled-SMO-Architecture [4], section 5.13.1, a Policy refers to a set of rules, guidelines, or conditions that govern the behavior and actions of O-RAN resources and services. These policies can be used for energy savings in O-Cloud. + +## 4.3 Architecture options to achieve energy savings optimisation + +### 4.3.1 Overview + +O-Cloud Node resources (for example compute, network, storage) used by an NF Deployment can be optimised to reduce power consumption based on current or predicted resource usage. The following sections examine how energy savings optimisations can be applied to the O-Cloud using the O-RAN architecture and interfaces and identify any potential changes. + +NOTE: There can be other possible alternatives to achieve Energy Savings and Optimisation that are not presented in the present document version. + +### 4.3.2 Energy Saving Policy applied via Kubernetes API + +Description: + +- NF Deployments can be deployed with Kubernetes Extended Resources that are associated with a specific power management configuration of the node resources. +- For example, CPU cores on a particular node are set to a certain idling mode (e.g., c1), when NF Deployment is created the container(s) that requested these cores via the Extended Resource will use them. +- Please note that Extended Resources can also be associated with a setup that is more dynamic, it depends on the operator/controller features, for example, changing configuration of resources used by the NF Deployments during a certain time of a day. +- SMO via rApp can learn traffic patterns and modify the Extended Resources configuration. For example, changing the hours that application is using a high performance cores and low performance cores due a change in traffic consumption. + +NOTE 1: The realization of this option is done with Kubernetes's operators - Custom Resources define the energy saving capabilities and expose it to the NF Deployments via Extended Resources which are declared as part of NF Deployment manifests (e.g., helm charts). + +NOTE 2: SMO/rApp communicates changes to the Custom Resources. + +NOTE 3: Kubernetes® and K8s® are registered trademarks of the Linux Foundation, in the United States and other countries. + +![Figure 4.3-1: Energy Saving Policy applied via Kubernetes® API. The diagram shows a purple box labeled 'SMO' containing a green box labeled 'Non-Real Time RIC'. A callout box points to the 'Non-Real Time RIC' with the text: 'Non-Real Time RIC collects performance data from the cloud (O2) and performance data from the application (O1) and creates energy savings policy'. Below the SMO, there are two vertical lines labeled 'O1' and 'O2'. A callout box points to 'O1' with the text: 'RAN application provides the relevant performance data to the SMO (e.g. cell site traffic)'. A callout box points to 'O2' with the text: 'Power consumption KPIs Power savings policy'. At the bottom, there is a green box labeled 'O-Cloud' containing a red box labeled 'NF'.](fdfdf06f3c0d9e960d530795927d7054_img.jpg) + +Figure 4.3-1: Energy Saving Policy applied via Kubernetes® API. The diagram shows a purple box labeled 'SMO' containing a green box labeled 'Non-Real Time RIC'. A callout box points to the 'Non-Real Time RIC' with the text: 'Non-Real Time RIC collects performance data from the cloud (O2) and performance data from the application (O1) and creates energy savings policy'. Below the SMO, there are two vertical lines labeled 'O1' and 'O2'. A callout box points to 'O1' with the text: 'RAN application provides the relevant performance data to the SMO (e.g. cell site traffic)'. A callout box points to 'O2' with the text: 'Power consumption KPIs Power savings policy'. At the bottom, there is a green box labeled 'O-Cloud' containing a red box labeled 'NF'. + +**Figure 4.3-1: Energy Saving Policy applied via Kubernetes® API** + +### 4.3.3 Energy Saving Policy applied by NF Deployment + +Description: + +- In this option the energy saving policy can be applied by the SMO and can be adjusted by the NF Deployment or available directly from the NF Deployment, meaning that that NF Deployment applies its energy saving policy without the need of the SMO, if it has the capability of doing so. +- For example, initial policy was requested for low power consumption between 2AM and 5AM, however, due to traffic increase the application adjusts its assigned resources to accommodate the new traffic demand. +- NF Deployment uses O-Cloud resource interface to adjust power management of its assigned resources (potential new interface between the NF Deployment and O-Cloud). + +NOTE 1: This option requires a new interface between the NF Deployment and O-Cloud (cloud platform) to adjust the power consumption of its assigned resources but applies only for the cases where Node Cluster resources are exclusively assigned to the NF Deployment, not being shared with other entities and other Deployment in the Node Cluster, for example, vfiio. + +NOTE 2: It is the responsibility of the cloud platform to determine if the resources that are assigned to the NF Deployment are shared or not. Requests for shared resources will not be granted and will be denied. + +NOTE 3: To implement such interface, the O-Cloud (cloud platform) exposes an endpoint to the NF Deployment, for example, this exposure can be done via the Pod environment variables, exposing a certain port on the Pod's localhost. + +NOTE 4: This architecture option is allowing NF Deployment to adjust its own allocated/assigned resources directly and fast (low latency) when traffic suddenly changes, however, this option could potentially face conflicting requests and/or race conditions especially if also controlled by SMO, which need to be taken into account when considering this option and creating requirements accordingly. + +![Figure 4.3-2: Energy Saving Policy applied by NF Deployment. The diagram shows the SMO (Service Management Orchestrator) containing the Non-Real Time RIC. The Non-Real Time RIC collects performance data from the cloud (O2) and performance data from the application (O1) to create an energy saving policy. The RAN application provides relevant performance data to the SMO (e.g., cell site traffic). The Non-Real Time RIC also collects power consumption KPIs and power saving policy (DMS) from the O-Cloud. The O-Cloud resource interface allows the NF Deployment to adjust its assigned resources during runtime (e.g., changes to the cores p/c-state) based on the policy from SMO or NF Deployment. The O-Cloud contains assigned resources.](d83e9d62dd9a1f079897d2bc11e324d3_img.jpg) + +Figure 4.3-2: Energy Saving Policy applied by NF Deployment. The diagram shows the SMO (Service Management Orchestrator) containing the Non-Real Time RIC. The Non-Real Time RIC collects performance data from the cloud (O2) and performance data from the application (O1) to create an energy saving policy. The RAN application provides relevant performance data to the SMO (e.g., cell site traffic). The Non-Real Time RIC also collects power consumption KPIs and power saving policy (DMS) from the O-Cloud. The O-Cloud resource interface allows the NF Deployment to adjust its assigned resources during runtime (e.g., changes to the cores p/c-state) based on the policy from SMO or NF Deployment. The O-Cloud contains assigned resources. + +Figure 4.3-2: Energy Saving Policy applied by NF Deployment + +# 5 Energy Savings Use Cases + +## 5.1 Use Case 1: O-Cloud Node Shutdown in Idle Mode + +### 5.1.1 Overview + +This use case describes a method to perform O-Cloud Energy Saving by shutting down O-Cloud Node(s) in idle times through Non-RT RIC provided guidance. + +Typically, Virtual Network Functions (VNFs) can be represented as single or chains of cloud resources (Virtual Machines (VMs) or containers) which are deployed inside data centers on a O-Cloud site. . In order to achieve cost efficiency, network operators aim at minimizing the power consumption of their NFV infrastructure. This can be achieved by using the minimum set of physical servers required by the virtual functions in terms of computing, memory, disk related parameters. + +A O-Cloud Node as defined in O-RAN.WG6.CADS [1] is the basic computational resource designator and can be commonly thought of as a server. Programs running on Nodes are packaged as workloads. A cloud resource might comprise functionalities supporting one or multiple NF(s) or parts of one or multiple NF(s). In such a O-Cloud environment, some nodes may become idle as workloads shift and change. By identifying and shutting down these idle nodes, energy consumption can be reduced, leading to cost savings and increased efficiency in resource utilization. + +Non-RT RIC can collect O1 and O2 related data, store data patterns and resource usage (CPU, memory, network, etc.) of O-Cloud Nodes. This data is utilized to train a predictive model that can identify idle times when the resources are not being utilized. + +Based on the predictions, non-RT RIC can recommend the shutting down of idle O-Cloud Nodes to reduce costs and improve efficiency. It is imperative to note that the non-RT RIC takes into consideration the potential impact of shutting down an idle node on future system performance. Therefore, the Non-RT RIC will only recommend shutting down a node if it predicts a prolonged period of idleness, in order to avoid unnecessary and frequent shutdowns and startups of nodes. + +**NOTE:** This use-case takes into consideration the assumption that the Nodes are idle, and SMO have relocated the workloads that are not autonomously relocated by the DMS. + +### 5.1.2 Description and UML Diagrams + +**Table 5.1-1: O-Cloud Node Shutdown in Idle Mode Sequence Description** + +| Use Case Stage | Evolution / Specification | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | Shutting down of O-Cloud Node(s) in idle times for energy saving purpose. | +| Actors and Roles | Cloud Maintainer: Recommend O-Cloud Node Shutdown<br>SMO (FOCOM/NFO) : Actions to implement goal<br>Non-RT RIC Including rAPP : O1 & O2 related data analysis, recommendation to trigger O-Cloud Node shutdown<br>NF – Network Function (Application) | +| Assumptions | <ul style="list-style-type: none"> <li>- The “Service Request” to the FOCOM includes the identifiers of the O-CloudNode(s) to be shut down.</li> <li>- The trigger can be given from the Cloud Install Project Manager or rApps (via Non-RT RIC).</li> <li>- The Cloud Maintainer or rApp has subscribed to receive notifications from the SMO.</li> <li>- SMO (FOCOM/NFO) can get recommendation from rApps via Non-RT RIC, where rApps has its own algorithm that decides when to shut down O-Cloud HW nodes.</li> </ul> | +| Pre- conditions | <ul style="list-style-type: none"> <li>- SMO is available</li> <li>- O-Cloud is available</li> <li>- O2-IMS alarm events have been subscribed by Cloud Maintainer and or Non-RT RIC.</li> <li>- Non-RT RIC/rApp can receive O-Cloud telemetry data from FOCOM.</li> <li>- SMO has relocated the workloads that are not autonomously relocated by the DMS</li> <li>- The Non-RT RIC has processed a recommendation for shutting down a O-Cloud HW Node(s), based on the prediction of an extended period of idleness for the involved O-Cloud Node(s).</li> </ul> | +| Begins when | The recommendation for shutting down existing O-Cloud Node(s) has been completed Cloud Maintainer or by rApps via Non-RT RIC. | +| Step 1,2 (M) | Cloud Maintainer or rApps via Non-RT RIC recommends FOCOM to shut down the O-Cloud HW node(s) | +| Step 3 (M) | FOCOM requests to IMS to shutdown down one or more O-Cloud HW Nodes. | +| Step 4 (M) | IMS shutdown the requested O-Cloud nodes. | +| Step 5 (M) | IMS informs SMO that the O-Cloud HW Node(s) Shutdown is completed. | +| Step 6 (M) | FOCOM informs Non-RT RIC (rApp) through SMO that the O-Cloud HW Node(s) Shutdown is completed. | +| Ends when | O-Cloud HW node(s) have been shut down. | +| Post-conditions | O-Cloud HW Node(s) have been Shut down for energy saving.<br>SMO/Non-RT RIC continues to monitor the load on the O-Cloud by collecting and monitoring the relevant performance and matrices using O1 and O2. | +| Traceability | Traceability has not been specified in the present document. | + +![Sequence diagram for O-Cloud Node Shutdown in Idle Mode. The diagram shows interactions between Personnel (Cloud Maintainer), Service Management & Orchestration Framework (rApp & Non-RT RIC, FOCOM), and O-Cloud Platform (IMS). The process starts with data collection and analysis, followed by optional NF relocation and node draining. Then, a shutdown request is sent to the O-Cloud Platform, which performs the shutdown and sends status notifications back to the Service Management & Orchestration Framework. The process ends with an 'End Use Case' label.](0d361550821fc22b70c4e3d673750d27_img.jpg) + +``` + +sequenceDiagram + participant Personnel as Personnel +Cloud Maintainer + participant SMO as Service Management & Orchestration Framework +rApp & Non-RT RIC + participant FOCOM + participant OCP as O-Cloud Platform +IMS + + Note over Personnel, SMO: Cloud Maintainer or rApp collects O1 & O2 related telemetry data. Analysis optionally with AIML to determine when to perform O-Cloud Node Shutdown. + Note over SMO: O-Cloud Data Collection & Analysis + Note over SMO: [Optional] NF Relocation & O-Cloud Node Draining + Note over SMO: When O-Cloud node is operating at low load, then the deployed Network Functions or its microservices can be relocated to free up O-Cloud nodes. Post relocation O-Cloud Node(s) to be drained. + Note over SMO: O-Cloud Node Shutdown + alt alt + 1 Request to Shutdown O-Cloud Node(s) + 2 Request to Shutdown O-Cloud Node(s) + end + loop loop [for NF(s) on single or multiple each O-cloud Node(s)] + 3 <<O2>> Shuwtdown O-Cloud Node(s) + 4 Shutting Down O-Cloud Node(s) + 5 <<O2>> O-Cloud Status Notification + 6 O-Cloud Status Notification + 7 O-Cloud Status Notification + end + Note over SMO: End Use Case + +``` + +Sequence diagram for O-Cloud Node Shutdown in Idle Mode. The diagram shows interactions between Personnel (Cloud Maintainer), Service Management & Orchestration Framework (rApp & Non-RT RIC, FOCOM), and O-Cloud Platform (IMS). The process starts with data collection and analysis, followed by optional NF relocation and node draining. Then, a shutdown request is sent to the O-Cloud Platform, which performs the shutdown and sends status notifications back to the Service Management & Orchestration Framework. The process ends with an 'End Use Case' label. + +Figure 5.1-1: O-Cloud Node Shutdown in Idle Mode + +### 5.1.3 Potential Requirements + +NOTE: Potential requirements for WG6, as well as high level requirements for other O-RAN WGs have not been specified in the present document. + +## 5.2 Use Case 2: CPU core frequency and pinning configuration change by SMO + +### 5.2.1 Overview + +This Use Case describes CPU core frequency and pinning changes for O-Cloud platform based on energy saving policy which is generated by non-RT RIC or Cloud Operator, especially for the CPU allocated to VNF/CNF in idle or low CPU utilization/load to save energy. This can be one of the possible deployment scenarios, for instance, small site deployment scenarios. + +When the service throughput or UE numbers are low, as well as CPU utilization or load of VNF/CNF is low, the CPU frequency mode allocated to dedicated VNF/CNF can be changed to energy saving mode, or some of the CPU cores for dedicated VNF/CNF can be closed based on the CPU core pinning, or the CPU states for dedicated VNF/CNF can be changed to save O-Cloud energy. + +For Example: O-Cloud telemetry data, such as CPU Frequency, CPU Utilization, CPU Temperature, CPU State etc., can be collected through O2ims and O2dms and reported to SMO. Furthermore, configuration data of the CPU, such as CPU core pinning information, vCPU number etc., can be collected by SMO as well as sent by O-Cloud to SMO through O2 interface. Then the O-Cloud energy saving policy based on SMO pre-configured or generated by Cloud Operator or Non-RT RIC/rApp, such as CPU frequency mode or CPU cores configuration for dedicated VNF/CNF, will + +be generated and provided through O2ims/O2dms to help update VNF/CNF deployment for energy saving. Furthermore, the O-Cloud energy saving policy generation could be further combined with O1 telemetry data for VNF/CNF to ensure VNF/CNF performance. + +NOTE 1: In this use case, O-Cloud energy saving policy can be pre-configured by SMO, given from Cloud Operator to NFO/FOCOM or it can be automatically triggered from Non-RT RIC/rApp. + +NOTE 2: In this use case, O1 telemetry data integration with O-Cloud energy saving policy generation is out of the scope of the present document. + +NOTE 3: This use case may be applicable for scenarios where the dedicated/isolated cores are allocated for an application. + +NOTE 4: The scenarios for shared cores between different applications has not been specified in the present document. + +NOTE 5: At the time of developing this use case, the overall energy saving policy concept has not yet fully developed. Also, the roles and responsibility of NFO, FOCOM, DMS, IMS and non-RT/rApp needs to be further aligned. It is expected that the potential requirements which are described in clause 5.2.3 will be refined as energy saving policy concept and architecture evolve. + +### 5.2.2 Description and UML Diagrams + +**Table 5.2-1: CPU core frequency and pinning configuration Sequence Description** + +| Use Case Stage | Evolution / Specification | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | CPU core frequency and pinning configuration for O-Cloud platform, especially for the CPU allocated to VNF/CNF in idle or low CPU utilization/load to save energy. | +| Actors and Roles | Cloud Operator<br>SMO:<br>NFO, FOCOM<br>Non-RT RIC/rApp<br>O-Cloud Platform: DMS, IMS | +| Assumptions | <ul style="list-style-type: none"> <li>- The “Service Request” for data collection and deploy management includes the identifiers of the target VNF/CNF instances and the O-Cloud node where the VNF/CNF is located.</li> <li>- The O-Cloud energy saving policy can be pre-configured by SMO internally, or given from the Cloud Operator or Non-RT RIC/rApps.</li> <li>- NFO can get trigger from Non-RT RIC/rApp, where rApps has its own algorithm which decides what CPU configuration for VNF/CNF, and when to update it.</li> </ul> | +| Pre- conditions | <ul style="list-style-type: none"> <li>- SMO is available</li> <li>- O-Cloud is available</li> <li>- VNF/CNF has been successfully deployed.</li> <li>- VNF/CNF monitoring is in place and active.</li> <li>- Non-RT RIC/rApp can receive O-Cloud telemetry data from O2 interface.</li> </ul> | +| Begins when | The energy saving related data is to be collected and CPU configuration, such as CPU frequency mode or CPU cores for dedicated VNF/CNF is to be determined. | +| Step 1 (M) | <p>The O-Cloud telemetry data is received by SMO through O2 interface, for example FOCOM receives O-Cloud IMS telemetry data through O2ims, and NFO receives O-Cloud DMS telemetry data through O2dms.</p> <p>Alternatively, the O-Cloud telemetry data, including IMS and DMS telemetry data can be further reported to Non-RT RIC/rApp or Cloud Operator.</p> <p>The O-Cloud telemetry data may includes CPU Frequency, CPU Utilization, CPU Temperature, CPU power State, etc to help generate O-Cloud CPU configuration.</p> | +| Step 2 (O) | Non-RT RIC/rApp or Cloud Operator monitors O-Cloud performance based on the received O-Cloud telemetry data, and based on such telemetry data, it generates an O-Cloud energy saving policy. | +| Step 3 (O) | Non-RT RIC/rApp or Cloud Operator send the O-Cloud energy saving policy to NFO or FOCOM. | +| Step 4 (M) | SMO(NFO/FOCOM) sends CPU configuration request to O-Cloud through O2dms or O2ims such as CPU frequency mode, CPU core pinning configuration for dedicated VNF/CNF, vCPU number, which indicates the CPU configuration for O-Cloud network functions, based on the received O-Cloud telemetry data as well as the energy saving policy pre-configured by SMO internally, or generated by Cloud Operator or Non-RT RIC/rApp(see note). | +| Step 5 (M) | O-Cloud IMS or DMS updates the VNF/CNF deployment based on the CPU configuration from NFO or FOCOM, such as configuring CPU frequency mode or configuring CPU core pinning. | +| Step 6 (M) | O-Cloud DMS or IMS informs SMO that the CPU configuration for VNF/CNF is completed. | +| Step 7 (O) | SMO informs Non-RT RIC/rApp or Cloud Operator the change of CPU configuration. | +| Ends when | The CPU configuration action for VNF/CNF is completed successfully. | +| Exceptions | The CPU configuration action for VNF/CNF is failed during the execution of the configuration change, such as the VNF/CNF have been terminated or corresponding O-Cloud HW node have been shut down. | +| Post-conditions | SMO continues to monitor the performance on the O-Cloud by collecting and monitoring the relevant matrices through O2 interface. | +| Traceability | [5.2.3.1] [5.2.3.2] [5.2.3.4] [5.2.3.5] | +| NOTE: | The application downtime while change the CPU configuration will depend on the implementation, such as the running applications as well as the applications that accept downtime within a certain range. | + +![Sequence diagram showing CPU core frequency and pinning configuration change by SMO. The diagram involves three main lifelines: Personnel (Cloud Operator), Service Management & Orchestration Framework (Non-RT RIC/rApp, NFO, FOCOM), and O-Cloud Platform (DMS, IMS). The process starts with a note that the Cloud Operator has installed O-Cloud infrastructure. It then proceeds to O2 Data Collection, where telemetry data is retrieved from O2ims and O2dms. This is followed by the generation of O-Cloud Energy Saving Policy. The main part of the diagram is divided into two sections: CPU frequency mode configuration and CPU core pinning configuration. In the frequency mode section, the Non-RT RIC/rApp generates a policy, sends a request to O2ims, which then configures the CPU frequency mode in the O-Cloud Platform and sends a response back. In the core pinning section, the Non-RT RIC/rApp generates a policy, sends a request to O2dms, which then configures CPU core pinning in the O-Cloud Platform and sends a response back. Both sections end with notifications from the O-Cloud Platform back to the Non-RT RIC/rApp.](9a40f8bd35f7408224d1ee1180ae6d2e_img.jpg) + +``` + +sequenceDiagram + participant Personnel as Personnel +Cloud Operator + participant SMO as Service Management & Orchestration Framework +Non-RT RIC/rApp NFO FOCOM + participant OCP as O-Cloud Platform +DMS IMS + + Note over Personnel, SMO: Cloud operator has installed O-Cloud infrastructure, and VNFs/CNFs have been instantiated + Note over SMO: O2 Data Collection + Note over SMO: O2ims & O2dms telemetry data such as CPU Frequency, CPU Utilization, CPU core Pining, vCPU number, CPU Temperature, CPU State etc of O-Cloud to be retrieved + loop + alt + SMO->>OCP: 1.1 «O2ims» Data Retrieval + OCP-->>SMO: 1.2 «O2dms» Data Retrieval + alt + SMO->>SMO: Non-RT RIC/rApp collects O2 telemetry data + Personnel->>SMO: Cloud Operator collects O2 telemetry data + end + end + Note over SMO: O-Cloud Energy Saving Policy + alt + SMO->>SMO: 2.1 Generate O-Cloud ES policy & Monitor performance + SMO->>SMO: 2.2 Generate O-Cloud ES policy & Monitor performance + end + Note over SMO: CPU Configuration of O-Cloud VNF/CNF + CPU frequency mode configuration + alt + SMO->>SMO: 3.1.1 O-Cloud ES policy + SMO->>SMO: 3.1.2 O-Cloud ES policy + SMO->>OCP: 4.1 «O2ims» CPU frequency mode configuration request + OCP->>OCP: 5.1 Configure CPU frequency mode + OCP-->>SMO: 6.1 «O2ims» CPU frequency mode configuration response + alt + SMO->>SMO: 7.1.1 Notify the change of CPU + SMO->>SMO: 7.1.2 Notify the change of CPU + end + CPU core pinning configuration + alt + SMO->>SMO: 3.2.1 O-Cloud ES policy + SMO->>SMO: 3.2.2 O-Cloud ES policy + SMO->>OCP: 4.2 «O2dms» CPU core pinning configuration request for VNF/CNF + OCP->>OCP: 5.2 Configure CPU core pinning + OCP-->>SMO: 6.2 «O2dms» CPU core pinning configuration response + alt + SMO->>SMO: 7.2.1 Notify the change of CPU + SMO->>SMO: 7.2.2 Notify the change of CPU + end + +``` + +Sequence diagram showing CPU core frequency and pinning configuration change by SMO. The diagram involves three main lifelines: Personnel (Cloud Operator), Service Management & Orchestration Framework (Non-RT RIC/rApp, NFO, FOCOM), and O-Cloud Platform (DMS, IMS). The process starts with a note that the Cloud Operator has installed O-Cloud infrastructure. It then proceeds to O2 Data Collection, where telemetry data is retrieved from O2ims and O2dms. This is followed by the generation of O-Cloud Energy Saving Policy. The main part of the diagram is divided into two sections: CPU frequency mode configuration and CPU core pinning configuration. In the frequency mode section, the Non-RT RIC/rApp generates a policy, sends a request to O2ims, which then configures the CPU frequency mode in the O-Cloud Platform and sends a response back. In the core pinning section, the Non-RT RIC/rApp generates a policy, sends a request to O2dms, which then configures CPU core pinning in the O-Cloud Platform and sends a response back. Both sections end with notifications from the O-Cloud Platform back to the Non-RT RIC/rApp. + +Figure 5.2-1: CPU core frequency and pinning configuration change by SMO + +### 5.2.3 Potential Requirements + +#### 5.2.3.1 General + +O2 supports O-Cloud information to identify the cluster and the network function instance. + +#### 5.2.3.2 Measurement and Configuration data + +O-Cloud resource consumption and configuration are made available to SMO through O2 interface. + +#### 5.2.3.3 Security + +NOTE: Potential requirements for security have not been specified in the present document. + +#### 5.2.3.4 O-Cloud Support + +This use case has multiple dependencies of O-Cloud capabilities: + +- O-Cloud has a capability to collect the O-Cloud hardware resource information and telemetry such as CPU Frequency, CPU Utilization, CPU core Pinning, vCPU number, CPU Temperature, CPU State. +- O-Cloud has a capability to expose or share O-Cloud hardware resource data to SMO through O2 interface. +- O-Cloud has a capability to receive specific CPU configuration of specific NF deployment instance, where CPU configuration data can be CPU Frequency, CPU core Pinning. + +#### 5.2.3.5 High Level Requirements for other O-RAN WGs + +Different options for O-Cloud energy saving policy generated in this use case calls for jointly collaboration with different working WGs with a scope describing energy saving policy, architectures, and OAM, such topics are the following: + +- O-Cloud energy saving policy is made available by Cloud Operator, Non-RT RIC/rApp, or others. +- O-Cloud energy saving telemetry data (from O2) could be further combined with O1 telemetry data for VNF/CNF to ensure VNF/CNF performance. O1 integration is out the scope of the present document. +- SMO is capable to receive and process the energy saving policy. +- SMO has a capability to request the information once O-Cloud hardware resource changes. + +## 5.3 Use Case 3: C-state usage for NF Deployment + +### 5.3.1 Overview + +This Use Case describes a scenario where a NF Deployment may request deployment with a specific energy savings configuration (C-state configuration) of a CPU during NF Deployment instantiation. The O-Cloud may change the energy saving configuration to support such a request. + +### 5.3.2 C-state Configuration for NF Deployments + +The O-Cloud may need to support NF Deployments that have different deployment requirements for C-state configuration. In the figure below an example scenario is depicted where one NF Deployment (NF Deployment 1) supports up to C6 state while another NF Deployment (NF Deployment 2) only supports up to C1 state. In addition there can be scenarios that within a NF Deployment there may be different requirements for C-state control on a per core basis. In the same figure NF Deployment 2 has such a scenario where it requires several cores with C1-state enabled and one core (Core N) with C-states disabled (or only C0 enabled). + +The O-Cloud should also be capable of configuring the un-used cores into C6-state when there is no workload deployed on them, seen in the below figure in Core 2. + +![](27ff94a8bfab0df3e1df3e3455843da5_img.jpg) + +| OS / CaaS | | | VNF 1 | | | | VNF 2 | | | +|---------------|---------------|---------------|---------------|---------------|---------------|---------------|------------|------------|------------| +| C1/C6 enabled | C1/C6 enabled | C1/C6 enabled | C1/C6 enabled | C1/C6 enabled | C1/C6 enabled | C1/C6 enabled | C1 enabled | C1 enabled | C0 enabled | +| Core 0 | Core 1 | Core 2 | | | .... | | | | Core N | + +**Figure 5.3-1: C-state usage for NF Deployment** + +The main change for this use case is to support energy savings C-state configuration in the definition of the Deployment Artifact(s), which should be updated to include O-Cloud energy savings C-state. Placement of the application on a node supporting the requirements expressed in the artifact, C-state configuration, is the responsibility of the O-Cloud. + +### 5.3.3 Potential Requirements + +#### 5.3.3.1 General + +The deployment artifacts for the NF Deployment should allow the application vendors to specify their C-state requirements in a standardized way. + +#### 5.3.3.2 Measurement and Configuration data + +No measurement data required. + +#### 5.3.3.3 Security + +NOTE: Potential requirements for security have not been specified in the present document. + +#### 5.3.3.4 O-Cloud Support + +The O-Cloud should understand the C-state(s) requested for the NF Deployments and support the C-state configuration in the O-Cloud. + +#### 5.3.3.5 High Level Requirements for other ORAN WGs + +NOTE: Potential requirements for other O-RAN WGs have not been specified in the present document. + +## 5.4 Use Case 4: O-Cloud Node Cluster Mode Selection + +### 5.4.1 Overview + +This use case describes the processing of a request to select a specific Mode, as defined in section 4.2.2.3 on an O-Cloud Node Cluster, from the FOCOM towards the IMS over the O2ims interface. The use case aims to select a specific Mode, for instance, Eco Mode, to achieve energy savings on an O-Cloud Node Cluster. Before this use case is started, it is expected that the SMO has concluded that a specific Mode needs to be activated on an O-Cloud Node Cluster. When the use case is concluded, any modified O-Cloud (exposed) resources are updated by the IMS. + +The targeted Mode is expressed in the Cluster Template, defining the capabilities and capacities at the SMO level, whereas the configurations or policies are defined in the Cluster Template artifacts at the O-Cloud level. An O-Cloud Node Cluster supports different modes, and each individual mode has runtime settings. Furthermore, a Mode setting aims to operate the O-Cloud Node Cluster with a specific set of configurations or policies. + +Table 5.4-1 exemplifies the three types of Modes that can achieve varying level of energy savings in an O-Cloud Node Cluster. The examples are only provided for illustrative purposes in the context of the present use case. + +**Table 5.4-1: Examples of Modes and their Description** + +| Modes | Description | +|------------------|-----------------------------------------------------------------------------------------------------| +| Eco Mode | High Energy Savings for the O-Cloud resources | +| Balanced Mode | Strike a balance between Energy savings and Performance during varying levels of system utilization | +| Performance Mode | High performance and resource availability in O-Cloud without energy savings | + +### 5.4.2 Description and UML Diagrams + +**Table 5.4-2: O-Cloud Node Cluster Mode selection Sequence Description** + +| Use Case Stage | Evolution / Specification | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Goal | To achieve energy savings by selecting a specific Mode on an O-Cloud Node Cluster | +| Actors and Roles | SMO: FOCOM<br>O-Cloud: IMS | +| Pre- conditions | <ul style="list-style-type: none"> <li>- SMO and O-Cloud are available and have connectivity.</li> <li>- The Cluster Template for the O-Cloud Node Cluster is available, and it defines cluster available/supported Modes.</li> </ul> | +| Assumptions | <ul style="list-style-type: none"> <li>- There is always a single mode activated on an O-Cloud Node Cluster.</li> <li>- The SMO has concluded which specific Mode that needs to be activated on an O-Cloud Node Cluster, as known, e.g., based on the expected energy savings or performance gains, and the compatibility with the already deployed NF Deployments (if any).</li> <li>- The creation and updates of the O-Cloud Node Cluster (e.g., K8s Cluster) are performed according to the Cluster Template.</li> </ul> | +| Begins when | A specific Mode needs to be activated on an O-Cloud Node Cluster to achieve energy savings. | +| Step 1(M) | A Request to activate a particular Mode, e.g. “Eco” referenced in Cluster Template on O-Cloud Node Cluster (ClusterID) is sent from FOCOM to IMS. | +| Step 2(M) | IMS performs Mode activation on O-Cloud Node Cluster as per Cluster Template artifact defined in O-Cloud. | +| Step 3(ALT) | SUCCESS: IMS sends a success response to FOCOM for the activation of a particular Mode on the O-Cloud Node Cluster | +| Step 4 (ALT) | EXCEPTION: O-Cloud Node Cluster is unavailable | +| Step 5(ALT) | EXCEPTION: Insufficient O-Cloud Resources to activate a particular Mode on the O-Cloud Node Cluster | +| Step 6 (ALT) | EXCEPTION: IMS encountered an unexpected condition processing the request | +| Ends when | This use case ends when the activation request of Mode is successful, or an exception has been encountered. | +| Exceptions | <ul style="list-style-type: none"> <li>- CLUSTER UNAVAILABLE - The O-Cloud Node Cluster is Unavailable to activate a particular Mode</li> <li>- INSUFFICIENT RESOURCES - There are no sufficient O-Cloud Resources to activate a particular Mode on the O-Cloud Node Cluster</li> <li>- UNEXPECTED CONDITION - The IMS might not be able to activate requested Mode on an O-Cloud Node Cluster perhaps due to a software fault. In this case, the unexpected condition exception is encountered.</li> </ul> | +| Post-conditions | <p>Upon successful activation, the O-Cloud Node Cluster is operating in the specified Mode with its mode-specific run-time settings.</p> <p>Upon Failure, the O-Cloud Node Cluster remains in its previous operational state without any changes to the Mode.</p> | +| Traceability | [5.4.3.1], [5.4.3.2] | + +![Sequence diagram for O-Cloud Node Cluster Mode selection. The diagram shows interactions between FOCOM (Service Management & Orchestration Framework) and IMS (O-Cloud Platform (IMS/DMS)). The process starts with a prerequisite check (SMO is active, O-Cloud Platform is available). A reference step indicates a precondition: 'Create or Update O-Cloud Node Cluster (e.g. K8s Cluster) according to the Cluster Template which defines the cluster's available/supported Modes'. Step 1: FOCOM sends '«O2» Request O-Cloud Node Cluster (ClusterID) into a specific Mode e.g., "Eco" defined in Cluster Template' to IMS. Step 2: IMS sends 'Activate Mode e.g., "Eco" O-Cloud Node Cluster' to FOCOM. An alternative block follows: [Success] Step 3: FOCOM sends '«O2» Respond O-Cloud Node Cluster successfully activated into the requested Mode e.g., "Eco"' to IMS. Exceptions: [Exception: O-Cloud Node Cluster Unavailable] Step 4: FOCOM sends 'Respond O-Cloud Node Cluster Mode Activation: Error Cluster Unavailable' to IMS. [Exception: Insufficient O-Cloud Resources] Step 5: FOCOM sends 'Respond O-Cloud Node Cluster Mode Activation: Error Insufficient Resources' to IMS. [Exception: Unexpected Condition] Step 6: FOCOM sends 'Respond O-Cloud Node Cluster Mode Activation: Unexpected condition' to IMS. Each exception path ends with 'Use Case Ends'.](3e8ede1da0b9ddf3d1b03f0a72fc9b52_img.jpg) + +``` + +sequenceDiagram + participant FOCOM as FOCOM + participant IMS as IMS + Note over FOCOM,IMS: PREREQUISITE: +- SMO is active +- O-Cloud Platform is available and has connectivity to SMO + Note over FOCOM,IMS: ref +Precondition: Create or Update O-Cloud Node Cluster (e.g. K8s Cluster) according to the Cluster Template which defines the cluster's available/supported Modes + FOCOM->>IMS: 1 «O2» Request O-Cloud Node Cluster (ClusterID) into a specific Mode e.g., "Eco" defined in Cluster Template + IMS->>FOCOM: 2 Activate Mode e.g., "Eco" O-Cloud Node Cluster + alt [Success] + FOCOM->>IMS: 3 «O2» Respond O-Cloud Node Cluster successfully activated into the requested Mode e.g., "Eco" + else [Exception: O-Cloud Node Cluster Unavailable] + FOCOM->>IMS: 4 Respond O-Cloud Node Cluster Mode Activation: Error Cluster Unavailable + Note over FOCOM,IMS: Use Case Ends + else [Exception: Insufficient O-Cloud Resources] + FOCOM->>IMS: 5 Respond O-Cloud Node Cluster Mode Activation: Error Insufficient Resources + Note over FOCOM,IMS: Use Case Ends + else [Exception: Unexpected Condition] + FOCOM->>IMS: 6 Respond O-Cloud Node Cluster Mode Activation: Unexpected condition + Note over FOCOM,IMS: Use Case Ends + end + +``` + +Sequence diagram for O-Cloud Node Cluster Mode selection. The diagram shows interactions between FOCOM (Service Management & Orchestration Framework) and IMS (O-Cloud Platform (IMS/DMS)). The process starts with a prerequisite check (SMO is active, O-Cloud Platform is available). A reference step indicates a precondition: 'Create or Update O-Cloud Node Cluster (e.g. K8s Cluster) according to the Cluster Template which defines the cluster's available/supported Modes'. Step 1: FOCOM sends '«O2» Request O-Cloud Node Cluster (ClusterID) into a specific Mode e.g., "Eco" defined in Cluster Template' to IMS. Step 2: IMS sends 'Activate Mode e.g., "Eco" O-Cloud Node Cluster' to FOCOM. An alternative block follows: [Success] Step 3: FOCOM sends '«O2» Respond O-Cloud Node Cluster successfully activated into the requested Mode e.g., "Eco"' to IMS. Exceptions: [Exception: O-Cloud Node Cluster Unavailable] Step 4: FOCOM sends 'Respond O-Cloud Node Cluster Mode Activation: Error Cluster Unavailable' to IMS. [Exception: Insufficient O-Cloud Resources] Step 5: FOCOM sends 'Respond O-Cloud Node Cluster Mode Activation: Error Insufficient Resources' to IMS. [Exception: Unexpected Condition] Step 6: FOCOM sends 'Respond O-Cloud Node Cluster Mode Activation: Unexpected condition' to IMS. Each exception path ends with 'Use Case Ends'. + +Figure 5.4-1: O-Cloud Node Cluster Mode selection + +### 5.4.3 Potential Requirements + +#### 5.4.3.1 General + +Mode activation requests of Modes are made over O2ims interface. + +#### 5.4.3.2 O-Cloud Support + +1. The O-Cloud supports Mode activation requests from SMO, and the Mode is activated by the IMS. +2. The Cluster Template artifacts will include the realization definition of the Modes. + +# 6 Power Consumption, Energy Consumption and Efficiency Measurement and KPIs + +## 6.1 Overview + +In this section, measurements and KPIs related to power consumption, energy consumption and energy efficiency are described. Power, measured in watt (W), refers to the rate of using energy at any given moment, while energy, measured in watt-hours (Wh), kilowatt-hours (kWh) or joules (J), refers to the total amount of energy consumed over a period of time. Energy efficiency, measured in capacity/joule (J), is the relationship between the useful output and energy consumption. Energy efficiency can be achieved by reducing the power consumption to deliver the same output or by improving output delivered for the same energy consumption. + +## 6.2 Power, energy consumption metrics of Infrastructure + +### 6.2.1 Overview + +Measuring the energy consumption of O-Cloud Resources could potentially help in understanding the impact of potential energy saving optimisations on the O-Cloud resources. Such measurements also help determining whether the energy efficiency policies are having a desired effect, and helps to set new policies or update existing policies. + +NOTE 1: O-Cloud Resources can be physical or logical in nature. The listed measurements apply to both types, but logical resources require some level of computation and estimation. For example, VM-based O-Cloud Nodes might need computation, while physical O-Cloud Resources might gather the measurements from physical sensors. + +NOTE 2: The potential mapping between the existing energy savings use cases (in Clause 5) and power/energy consumption metrics of infrastructure is not specified in the present document version. + +### 6.2.2 Measurement and KPI Definition + +#### 6.2.2.1 O-Cloud Resource Power Consumption + +Table 6.2-1 lists the power consumption measurements at the O-Cloud Resource level. The metrics can be reported per O-Cloud Resource at a configurable interval, typically measured in minutes. + +**Table 6.2-1: O-Cloud Resource Infrastructure Power Consumption Metrics** + +| Measurement Data | | | +|----------------------|------------------------------------------------------------------------------------------|------| +| Name | Description | Unit | +| PowerCapacity | The total amount of power that can be allocated to the O-Cloud Resource (Instantaneous), | W | +| PowerConsumed | The actual power the O-Cloud Resource consumes (Instantaneous) | W | +| AveragePowerConsumed | The average power consumed by the O-Cloud Resource over a measurement window. | W | +| MaxPowerConsumed | Maximum power consumed by the O-Cloud Resource over a measurement window. | W | +| MinPowerConsumed | Minimum power consumed by the O-Cloud Resource over a measurement window. | W | + +The measurements in table 6.2-1 may apply to relevant O-Cloud Resources that consumes power and defined as a resource by the O-Cloud Operator. Please refer to the definitions and attributes of the O-Cloud Resource as specified in the O2 GA&P [6] and O-Cloud Infrastructure Inventory [7] respectively. + +As per section 3.9.8 of O2 GA&P [9], the PM dictionary is provided by the O-Cloud Resource type vendor, and it is expected that power and energy consumption metrics and KPIs can be made part of such a PM dictionary. + +NOTE: As per Section 3.9.10 of O2 GA&P [9], the O-Cloud Resource might directly provide the maximum, minimum, and average values, or the PM job might perform a semantic transformation on the primitive or raw measurements available in the PM dictionary. + +Relevant information on the measurements for the O-Cloud Resources, which are physical, is available in the DMTF Redfish specifications [8][9]. + +Energy consumption per O-Cloud Resource can be derived from the average power consumption metric, i.e., AveragePowerConsumed, over a period of time. The entity responsible for energy consumption measurement is out of scope of the present document. + +#### 6.2.2.2 O-Cloud Node Energy Consumption + +Table 6.2-2 lists the energy consumption measurements at the O-Cloud node resource level. The metrics can be reported per node at a configurable interval, typically measured in minutes. + +Table 6.2-2: O-Cloud Node Resource Energy Consumption + +| Measurement Data | | | +|-----------------------------|---------------------------------------------------------------------------------------------------------------------------|------| +| Name | Description | Unit | +| $EC_{\text{node,core}}$ | Represents the total energy consumption of all CPU cores on the node. | J | +| $EC_{\text{node,uncore}}$ | Represents the total energy consumption of uncore components (e.g., caches, memory controllers) on the node. | J | +| $EC_{\text{node,dram}}$ | Represents the total energy consumption of DRAM on the node. | J | +| $EC_{\text{node,package}}$ | Represents the total energy consumption of the CPU package on the node. | J | +| $EC_{\text{node,other}}$ | Represents the total energy consumption of other host components (e.g., network interfaces, storage devices) on the node. | J | +| $EC_{\text{node,acc}}$ | Represents the total energy consumption of hardware accelerators on the node. | J | +| $EC_{\text{node,platform}}$ | Represents the overall energy consumption of the entire host. | J | + +NOTE: Not all measurement data listed above is mandatory to be reported. The scope of this document doesn't address exposing the above metrics and KPIs over the O2 interface or collecting them for internal purposes by the O-Cloud. The future granularity of the metrics selected for standardization will take into account the impact on performance. The exact metric(s) to be used for power management is/are determined by various factors which include: + +- The nature of the workload of the NF deployment to be managed on the node. For example, if the workload is CPU bound, $EC_{\text{node,core}}$ may be used to assess its energy consumption. If the workload is memory bound or hardware accelerator bound, $EC_{\text{node,dram}}$ or $EC_{\text{node,acc}}$ may be used instead. +- The availability of counters from the hardware and O-Cloud vendors. +- The power measurement or estimation tool used. + +## 6.3 Power, Energy Consumption Metrics of Containers + +### 6.3.1 Overview + +Assessing container level power and energy consumption is crucial for determining the peak performance of the NF deployed on the O-Cloud, considering the energy usage during operation. These evaluations are also instrumental in measuring the efficacy of energy efficiency strategies, facilitating modifications to current policies, or the introduction of new ones, based on the results observed. For the execution of this function with Kubernetes, we suggest the incorporation of energy-related system statistics to be exported as metrics. + +### 6.3.2 Measurement and KPI Definition + +#### 6.3.2.1 Container Energy Consumption + +Table 6.3-1 lists the KPIs related to estimated container level energy consumption. + +Table 6.3-1: Container Energy Consumption + +| Measurement Data | | | +|--------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| Name | Description | Unit | +| $EC_{\text{container,total}}$ | Represents the total energy consumption across hardware components within a specified container. | J | +| $EC_{\text{container,core}}$ | Tracks the total energy used by a container's CPU cores, it can be measured or estimated. | J | +| $EC_{\text{container,dram}}$ | Indicates the cumulative energy draw of a container in DRAM, providing insight into its memory-related energy footprint. | J | +| $EC_{\text{container,uncore}}$ | Provides the accumulated energy consumption of specific uncore elements including the last-level cache, integrated hardware accelerator(s), and memory controller. | J | + +| | | | +|----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------| +| EC <sub>container, package</sub> | Provides a cumulative measurement of the energy consumed by the entire CPU socket, encompassing all cores and uncore components including the last-level cache, integrated hardware accelerator, and memory controller. It is generally expected that Package Energy is equivalent to the sum of CPU cores and hardware accelerator energy counters. | <b>J</b> | +| EC <sub>container, other</sub> | Represents energy consumption for non-CPU and non-DRAM components. To calculate individual component usage, this total is typically reduced by measured CPU and DRAM power. | <b>J</b> | +| EC <sub>container, acc</sub> | Measures the total hardware accelerator power consumption allocated to a particular container. | <b>J</b> | + +NOTE: The KPIs listed above are expected to undergo further analysis and possibly not all of them will become mandatory to be reported. The scope of this document doesn't address exposing the above metrics and KPIs over the O2 interface or collecting them for internal purposes by the O-Cloud. The future granularity of the metrics selected for standardization will take into account the impact on performance. The exact KPIs to be used for power management are determined by various factors which include: + +- The nature of the container workload to be monitored. For example, if the workload is CPU bound, EC<sub>container,core</sub> may be used to assess its energy consumption. If the workload is memory bound or hardware accelerator bound, EC<sub>container,dram</sub> or EC<sub>container,acc</sub> maybe be used instead. +- The availability of the counters from the hardware and O-Cloud vendors. +- The power measurement or estimation tool used. + +#### 6.3.2.2 Container resource utilization + +Table 6.3-2 lists the measurement data related to container level resource utilization. + +**Table 6.3-2: Container Resource Utilization** + +| Measurement Data | | | +|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------| +| Name | Description | Unit | +| CPU Time | This metric captures the container's total CPU usage, measured through CPU time, that is reported by the tracing technology. It is used as an input for power estimation models. | <b>us</b> | + +For details on a power modeling example, please refer to Annex A, Section A.1 + +## 6.4 Power, energy consumption metrics of NF deployment and Cloudified NF + +### 6.4.1 Overview + +Measuring the power and energy consumption of O-Cloud Resources associated with an NF Deployment and Cloudified NF could help monitor and analyze energy consumption per NF Deployment and Cloudified NF on an O-Cloud. Such measurements also help determining whether the energy efficiency policies are having a desired effect, and helps to set new policies or update existing policies. + +NOTE: The potential mapping between the existing energy savings use cases (in Clause 5) and power/energy consumption metrics of NF deployment/Cloudified NF is not specified in the current O-Cloud Energy Savings TR document. + +### 6.4.2 Measurement and KPI Definition + +#### 6.4.2.1 NF Deployment power and energy consumption + +As been studied in ETSI GR NFV-EVE 021 [10], clause 7.2.20, the power/energy consumption of NF Deployment can be either estimated based on the relative resource usage of the monitored object with respect to other monitored objects placed on the same compute resource or obtained through "real" measurement by an entity (e.g., an OS tool) which can measure the power consumption of the monitored object. + +For estimated NF Deployment energy consumption, clause 6.7.3.1.4 of 3GPP TS 28.554 [11] specifies the "estimated virtual compute resource instance energy consumption based on mean vCPU usage". In this case, the energy consumption of a virtual compute resource instance is estimated as a proportion of the energy consumption of the O-Cloud Node on which the resource instance runs. The proportion is obtained by dividing the vCPU mean usage of the virtual compute resource instance by the sum of the vCPU mean usage of all virtual compute resource instances running on the same O-Cloud Node. Table 6.4-1 and Table 6.4-2 list the KPIs related to estimated NF Deployment power and energy consumptions. + +**Table 6.4-1: Estimated NF Deployment Power Consumption** + +| KPI | | | +|--------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| Name | Description | Unit | +| $P_{NF}$<br>Deployment,<br>estimated | A KPI that gives an estimation of the power consumption of a NF deployment running in the O-Cloud. This KPI is derived from the power consumption of O-Cloud Resources allocated to that NF Deployment based on the mean usage of the resource (e.g. vCPU mean usage). | W | + +**Table 6.4-2: Estimated NF Deployment Energy Consumption** + +| KPI | | | +|---------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| Name | Description | Unit | +| $EC_{NF}$<br>Deployment,<br>estimated | A KPI that gives an estimation of the energy consumption of a NF deployment running in the O-Cloud. This KPI is derived from the energy consumption of O-Cloud resources allocated to that NF Deployment based on the mean usage of the resource (e.g. vCPU mean usage). | J | + +As being an estimation above, its value might not be accurate enough. Therefore, other forms to measuring the power/energy consumption of NF Deployment is still an open issue. An example solution for obtaining more granular and refined estimation - "real" measured value of the monitored object has been studied and introduced in ETSI GR NFV-EVE 021 [10]. The exact mechanism for computing the "real" measured power consumption of NF Deployment might be left to vendor specific implementation and left outside the standardization scope. This computation can leverage standardized metrics regarding the "real" measured power consumption of individual components conforming the NF Deployment. + +NF Deployment level power and energy consumption estimation require inventory knowledge of the NF Deployment deployed on the O-Cloud Nodes and their resources usage (e.g., CPU usage). + +#### 6.4.2.2 Cloudified NF power and energy consumption + +Table 6.4-3 and Table 6.4-4 list the KPIs related to estimated Cloudified NF power and energy consumption. + +**Table 6.4-3 Estimated Cloudified NF Power Consumption** + +| KPI | | | +|-----------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| Name | Description | Unit | +| $P_{cloudifiedNF}$ ,<br>estimated | A KPI that gives an estimation of the power consumption of a Cloudified NF. This KPI is obtained by summing up the estimated power consumption of its constituent NF deployment(s). | W | + +**Table 6.4-4 Estimated Cloudified NF Energy Consumption** + +| KPI | | | +|------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| Name | Description | Unit | +| $EC_{cloudifiedNF}$ ,<br>estimated | A KPI that gives an estimation of the energy consumption of a Cloudified NF. This KPI is obtained by summing up the estimated energy consumption of its constituent NF deployment(s). | J | + +## 6.5 Energy efficiency of Cloudified NF + +### 6.5.1 Overview + +Assessing energy efficiency KPI of a Cloudified NF, is crucial for understanding whether the Cloudified NF deployed on the O-Cloud is performing optimally considering the energy consumed for its operation. Such measurements also help determining whether the energy efficiency policies are having a desired effect and helps to set new policies or update existing policies. + +NOTE: The potential mapping between the existing energy savings use cases (in Clause 5) and the energy efficiency of Cloudified NF is not specified in the present document version. + +### 6.5.2 Measurement and KPI Definition + +The approach for assessing energy efficiency of Cloudified NF strongly depends on the functionality and purpose of the Cloudified NF. In general, the energy efficiency of a Cloudified NF can be determined by assessing its delivered performance versus its energy consumption over a defined time interval following formula: + +$$EE_{cloudified\ NF} = \frac{Perf_{Cloudified\ NF}}{EC_{Cloudified\ NF}}$$ + +Wherein $Perf_{Cloudified\ NF}$ corresponds to the service performance of the Cloudified NF and $EC_{Cloudified\ NF}$ is the energy consumption associated to the Cloudified NF over a defined time interval as measured or estimated according to clause 6.4. + +The delivered performance can be based on different types of measures that are listed below depending on the exact service the Cloudified NF provides. + +**Table 6.5-1 Types of Energy Efficiency Measures** + +| Measurement Approach | Description | Unit | +|-------------------------------------------------------------------------------------------|---------------------------------------------------------------------------|---------------------------| +| Energy efficiency assessment based on PDCP SDU data volume | 3GPP TS 28.554 [11], clause 6.7.1 and ETSI ES 203 228 [12], clause 5.3 | bit/J | +| Energy efficiency assessment based on coverage | ETSI ES 203 228 [12], clause 5.3 | m <sup>2</sup> /J | +| Energy efficiency assessment based on latency (used for URLLC slice) | 3GPP TS 28.554 [11], clause 6.7.2.3.2 and ETSI ES 203 228 [7], clause 5.3 | (0.1ms * J) <sup>-1</sup> | +| Energy efficiency assessment based on both latency and data volume (used for URLLC slice) | 3GPP TS 28.554 [11], clause 6.7.2.2 and 6.7.2.2a | bit/(0.1ms*J) | +| Energy efficiency of registered subscribers (used for MIoT slice) | 3GPP TS 28.554 [11], clause 6.7.2.4.1 | user/J | +| Energy efficiency of number of active UEs (used for MIoT slice) | 3GPP TS 28.554 [11], clause 6.7.2.4.2 | user/J | + +NOTE: Further information on how these KPIs are calculated are available in the relevant 3GPP and ETSI specifications. Selection of a particular way of measuring the energy efficiency depends on the requirements, type of deployments and use-cases. It is expected that the SMO can compute the Energy consumption and efficiency of a Cloudified NF based on measurements from the O-Cloud. Energy efficiency calculations may involve collaboration with other working groups, such as WG10. + +In ETSI ES 203 228 [12], the time duration of the energy efficiency measurement is weekly, monthly, or yearly. + +# 7 Recommendations + +NOTE: There is no recommendation documented in the present document version. + +# 8 Conclusions + +NOTE: There is no conclusions documented in the present document version. + +# Annex A (Informative): + +## A.1 Power Modeling Example + +NOTE: This section includes informative references to industry implementations + +Kepler is a CNCF open source project that addresses the need to measure energy consumption in an O-Cloud. It provides pod-level power measurements based on two power modeling approaches. The modeling approach that is used depends on the constraints presented by the specific usage scenario. The usage scenarios may be broken down into two categories: + +1. Bare-Metal + - a. Bare-metal with direct access to real-time node power metrics via host OS APIs + - b. Bare-metal with no direct access to real-time node power metrics via host OS APIs, either due to security, performance, or configuration issues +2. VMs that do not support native access to real-time node power metrics + +Kepler uses a ratio method (Power Ratio Model) to attribute power consumption based on resource (cpu/dram/gpu) consumption. If a container uses x% of the resource, and the resource consumes y joules over the observation window, then the container is attributed x%\*y joules. + +For each resource, Kepler uses different ways to measure consumption. For CPU/DRAM, Kepler tracks how many CPU instructions (on bare metal servers) or CPU time (on VMs, if CPU instructions are not available) the processes within the container use. For DRAM consumption, Kepler uses cache misses (on bare metal servers) or a dirty page function call counter in the Linux kernel (on a VM, if cache misses are not readable). + +While the Power Ratio Model is always used, when direct access to real-time node power metrics is not available Power Estimation Modeling is used to calculate these inputs using Pre-trained Models. + +The resulting modeling approaches are as follows: + +- **Power Ratio Modeling:** Calculates granular power values. It determines detailed power consumption figures by dividing individual usage ratios by the overall power consumption. This approach is automatically employed when the total power consumption is readily available (default). +- **Power Estimation Modeling:** Power estimation is done by a trained model that leverages usage metrics as input features. This approach facilitates power estimation even in scenarios where direct power measurement is not feasible. The model supports estimation at three granularity levels: + - Node-level: encompassing total power consumption of a node, including fans, power supplies, and other ancillary components. + - Component-level: targeting power consumption of individual node components, such as CPUs and memory modules. + - Pod-level: targeting power consumption at the Kubernetes Pod level. + +(Also see [Get started with Kepler Model Server](../kepler\_model\_server/get\_started.md)) + +In scenarios where access to actual node power measurements is not available, such as for pods running on VMs in a public cloud, Pre-trained Power Models are used to calculate overall power consumption. + +Pre-trained Power Models (examples: ) can be leveraged for diverse deployment scenarios. These models support both power ratio and power estimation modeling for both RAPL (Runtime Average Power Limit) and ACPI (Advanced Configuration and Power Interface) power sources. Key features of the available models include: + +- **AbsPower models:** These estimate both idle and dynamic power consumption. +- **IdlePower models:** These focus solely on the idle power estimation that claims, but does not use, the resources. +- **DynPower models:** These focus solely on dynamic power estimation. + +To ensure model accuracy and transparency, the MAE (mean absolute error) for each model is also published. + +Example usage and application scenarios of different types of power modeling related to the metrics and KPIs described previously can be referenced from the table in [https://sustainable-computing.io/design/power\\_model/](https://sustainable-computing.io/design/power_model/). + +## Revision history + +| Date | Revision | Description | +|------------|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.08.03 | Skeleton 01.00 | Draft version 01.00 | +| 2022.10.07 | Skeleton 01.00 V13 | Skeleton approved | +| 2023.06.07 | Skeleton 01.00 v14 | Update Skeleton, add sections:<br>4.1 Architecture options to achieve CPU optimisation,<br>4.2 6 Energy Consumption and Efficiency - Measurements and Description | +| 2023.06.13 | TR 00.00.01 | Merge the approved CRs, including:<br>2022.11.16-WG6-CR-0001-O-RAN-O-Cloud-Energy-Saving-Introduction-v04,<br>2022.11.23-WG6-CR-0001-O-RAN-O-Cloud-Energy-Saving-background concepts assumptions-v05,<br>RMI-2022.11.30-WG6-CR-0003-O-RAN-O-Cloud-Energy-Saving-TR-Node-Shutdown-v07,<br>CMCC.AO-2022.10.12-WG6-CR-0001-O-RAN-O-Cloud-Energy-Saving-CPU core frequency and pinning configuration-v17 | +| 2023.10.18 | TR 00.00.02 | Merge the approved CR:<br>INT-2023.02.12-WG6-CR-0001-O-RAN-O-Cloud-Energy-Saving-Cstate-deployment v7 | +| 2023.10.27 | TR 00.00.03 | Merge the approved CR:<br>DELL.AO-2023.06.12-WG6-CR-0004-O-Cloud-Energy-Consumption-and-Efficiency-Measurements-v12 | +| 2024.03.11 | TR 00.00.04 | Merge the editorial CRs for TR:<br>NOK-2024.02.20-WG6-CR0108-Clause 6_x Editor's Notes propose change v3<br>VDF.AO-2024.02.24-WG6-CR-002-Incorporate Editor Notes-v04<br>CMCC.AO-2024.02.23-WG6-CR-0001-O-Cloud Energy Savings TR editorial changes-v04<br><br>Merge the technical CRs for TR:<br>WRS-AO_O-RAN.WG6.Architectures options for resource optimisation v10<br>NOK-2023.03-06-WG6-CR-068-Energy Savings in O-Cloud using modes-v11<br>NOK-2023.03.03-WG6-CR-0069- O-Cloud energy savings concepts and assumptions-v08.docx<br><br>Other editorial changes including references, styles and contents. | +| 2024.03.14 | TR 00.00.05 | Editorial changes including:<br>Remove the section 4.2.2 and 4.2.3 and move the contents to 4.2.1.1.<br>Update the wording in "Energy Saving Mode" to "Mode" and describe "for energy saving" in section 5.4.2 and 5.4.3.<br>Update the copyright to 2024 | +| 2024.03.21 | TR 00.00.06 | Editorial changes based on the comments received before Mar 21:<br>Update the wording in Introduction clause and 4.2.1.1<br>Update the typo, "TBD", title of table and style for the TR. | +| 2024.03.22 | TR 00.00.07 | Editorial changes based on the comments received on Mar 21:<br>Update the wording for the TR.<br>Add 2 NOTES for "Linux" and "Kubernetes and K8s" trademarks.<br>Re-organized some sub-sections to solve "hanging paragraphs". | +| 2024.07.11 | TR 01.00.01 | Editorial changes based on the received comments so far.<br><br>Merge the technical CRs for TR:<br>WRS-AO_O-RAN.WG6.Additional Architectures options for resource optimization v05<br>ERI.AO-2024.04.19-WG6-CR-0030-O-Cloud_Node_Cluster_Mode_Selection-v07<br>RHT.AO-2023.11.24-WG6-CR-0001-O-Cloud-Energy-Efficiency-Measurements-v0.17 | +| 2024.07.19 | TR 01.00.02 | Editorial changes based on the received comments so far. | +| 2024.07.21 | TR 01.00.03 | Editorial changes based on the received comments so far. | +| 2024.07.22 | TR | replacing the sentence "Not all KPIs listed above are mandatory to be reported" with "The KPIs listed above are expected to undergo further analysis and possibly not all of them will | + +| | | | +|--|----------|-------------------------------------------------------| +| | 01.00.04 | become mandatory to be reported” in the clause 6.3.2. | +|--|----------|-------------------------------------------------------| + +## --- History + +| Date | Revision | Description | +|------------|----------|----------------------------------| +| 2024.03.25 | 00.00.07 | Published as Final version 01.00 | +| 2024.07.22 | 01.00.04 | Published as Final version 02.00 | +| | | | +| | | | \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/07329e01d41f824bf831607665ded216_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/07329e01d41f824bf831607665ded216_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3e9ef5bdce3411503f9690a311c76913dee869df --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/07329e01d41f824bf831607665ded216_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:20b429d5bbeea333d44a7e818b9dfb586c5959a574e4ecb15f402b4c3b4ee713 +size 4057 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/14b518dc833a52da02b498efb2213305_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/14b518dc833a52da02b498efb2213305_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..192605818859b7273687f566c1e7295fb17ad7b9 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/14b518dc833a52da02b498efb2213305_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6bb9d6ac0eb182c851bf1ee27b945172748d06f9d7bc92c637da79c23fbad1e6 +size 72929 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/203e324f8174877a7fbea7ba6e42a54d_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/203e324f8174877a7fbea7ba6e42a54d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e6329c94cce26fe36eac8e94f16df8b6464c7ea --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/203e324f8174877a7fbea7ba6e42a54d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:111e97539cf46a5de505b4cb5eb72b43a2ffcefd5891640351bfeff2528b7b5b +size 127058 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/220f714d254aebd84a9b781f1ee77eb6_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/220f714d254aebd84a9b781f1ee77eb6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..da5d1ace7eef1dd6079fd57ab56d7ed83d3966c7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/220f714d254aebd84a9b781f1ee77eb6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c1b5a14360d0f0f79012df087fd08dbdf715e8a28c747555ea00808d35f3e188 +size 73125 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/26783e25c9c3af602e9cb84a79442729_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/26783e25c9c3af602e9cb84a79442729_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9556f9478b3a477dbb9c23f1a5ed29bafeab00d3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/26783e25c9c3af602e9cb84a79442729_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9362867eea49ddc1004b768e928e529b3e21e57a511fcc6de0560ad04f7bf696 +size 53995 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/2b5e58ee3c15a7bc83d13dd765d6410f_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/2b5e58ee3c15a7bc83d13dd765d6410f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..07fd19dde421bfb4acbba0768e8424e470e02d30 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/2b5e58ee3c15a7bc83d13dd765d6410f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:86517c158b8a916aaffad70ebb89948c9da19f89f01ad73aa47ff8853e3dc6a4 +size 78499 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/46d5d49a40c10b09b84e5325a0b241c8_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/46d5d49a40c10b09b84e5325a0b241c8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d5f025345d34b1e9835afd62c8f2736cf5b9dcb3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/46d5d49a40c10b09b84e5325a0b241c8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0d4e0c13335018efb44c13e570bc2c91bb5e8026f7cfb884d595aa3e63f09de0 +size 4018 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/473b24ed2fd603ada0a3005f79b2cc89_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/473b24ed2fd603ada0a3005f79b2cc89_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ec1b0e0a43f9c2c1511db811eacb64f58216dac2 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/473b24ed2fd603ada0a3005f79b2cc89_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1ad5370b4efa7cb748f6779d02785bf502f77506a534e9c397f1d9684c1e494e +size 57049 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/4e22ba1478b757619acc621afb48546a_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/4e22ba1478b757619acc621afb48546a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..14db302e0b1eea716d8f2664718abb88d4fc8326 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/4e22ba1478b757619acc621afb48546a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a333ac97785343c2bd130d383b61cf380aa2b73334153387818716a1b9b7ae83 +size 65742 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/4ed51ddc5dd355571eefdb827f4af46e_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/4ed51ddc5dd355571eefdb827f4af46e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..380e5f9396c4e80ec9e68340a6085e8044550ca3 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/4ed51ddc5dd355571eefdb827f4af46e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ada699e3e8463c70338bd83ad3fbfd81eed6011a8037331d8e41dc70bac39e8 +size 4065 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/52ed67c5f16424187e3d1d9c0d70b2cc_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/52ed67c5f16424187e3d1d9c0d70b2cc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..255b831055699bcefea03b4bc5893a33acf157a1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/52ed67c5f16424187e3d1d9c0d70b2cc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:41778ed1e264f0f33e41eccf1f6a4d2d6853040abc1ca8d87999ebbb9971d037 +size 4100 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/63e176ca325c7a67fa460e18cdb30e5c_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/63e176ca325c7a67fa460e18cdb30e5c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..68706db99f7806276ca7b60bd4a573a4b4bee510 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/63e176ca325c7a67fa460e18cdb30e5c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:343b00b5b037cea8835bf19fd7d234e98877eb76d16092ea7a3b95a1c457789a +size 3946 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/662e8a8d2cbcf1013824d829c35d318a_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/662e8a8d2cbcf1013824d829c35d318a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2126bf8e5a74784bee290dbc902adb85900aeaa --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/662e8a8d2cbcf1013824d829c35d318a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8aaff7f3e67d24d4b8df2894020eb93f1edaa14ad286099e036c3d76b002729 +size 4064 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/6c31df96b5bf6162ebdb452fcee9d3e2_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/6c31df96b5bf6162ebdb452fcee9d3e2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..759302c06f8712abc2d3ab17891b50ac2ed82c68 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/6c31df96b5bf6162ebdb452fcee9d3e2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:74fe77f2b8125906f517dc4e7987bd8411c1c67667f770f4a4d75a5529ea7ec5 +size 77602 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/6c5af5ac0c91a5b6dd8842fc048e8078_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/6c5af5ac0c91a5b6dd8842fc048e8078_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..77b136f6ce165ce76544187ea29edbbcf398a0cb --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/6c5af5ac0c91a5b6dd8842fc048e8078_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cb29b472492700e2596f119ea855377e6985a93301e24c421ea2cc950eb54117 +size 72835 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/713af17dae7cbeca98dc3859534cd979_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/713af17dae7cbeca98dc3859534cd979_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..64219d007059d990bf8db0fabebc4e9e5f274494 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/713af17dae7cbeca98dc3859534cd979_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:50197c4f299f6c120a16f3520f9bb2c57b4e4b10dce6c6702710b470b044f75f +size 115758 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/7b68ce883d868abb774ddd699124f3ac_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/7b68ce883d868abb774ddd699124f3ac_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e828f5f3937a5c7426e7071f840656de86107b7a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/7b68ce883d868abb774ddd699124f3ac_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:757d04a65c2c3de4a1ce07985916370b5caf7a9cb41214bfbf7645f0415b53d2 +size 4150 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/7f53f1375efa8dcb523e396c5d381213_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/7f53f1375efa8dcb523e396c5d381213_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..baf00f9ec61d2c8fdc3a2e7f04d0a7fe54a4f890 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/7f53f1375efa8dcb523e396c5d381213_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6f893d089150836ebfa7b72a18573e64dc5c5a1ef63e3d9ebb87e9860f3dcdff +size 4063 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/90a4cb7fe654c578eb9f73c7c2b2d925_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/90a4cb7fe654c578eb9f73c7c2b2d925_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ab3c00ccb58229a50e067976f3a8a3c38b9c6232 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/90a4cb7fe654c578eb9f73c7c2b2d925_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4978cc08f028f8fc7544316bbe760b525724b7426b8cedfa2d0604cad24aee8e +size 3971 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/9dc9fca8fa1974acc47c7c9320cc655a_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/9dc9fca8fa1974acc47c7c9320cc655a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..df504f5b800590d6b9a9bd8d634ae2ad3686278f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/9dc9fca8fa1974acc47c7c9320cc655a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f3de0b8ef9c9b8c8b7848ae1d8b3c7c1570edbeb526db6e1df4f85c9dee630b6 +size 51209 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/a4e76fc9633751a306acb4185ae59f5a_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/a4e76fc9633751a306acb4185ae59f5a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1b1d8c7a0cae1c55e2825836e45fcffe813c37f7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/a4e76fc9633751a306acb4185ae59f5a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a67965fddcdd00914cb35ea3d64f9904660b27d50318b105a3e99fff5b9ea2c4 +size 96683 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/a504c0bafa604076e995493d21d80e98_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/a504c0bafa604076e995493d21d80e98_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c91f8d90dc42f3bc573464cb50ddb21dda825d02 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/a504c0bafa604076e995493d21d80e98_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2dea4cc326b3e877f92fdaa00d45f0d547a7dbc33da9b8f7ecc0fcc37c1a938c +size 71035 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/ae4538d1497e37d21b75a5688827267d_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/ae4538d1497e37d21b75a5688827267d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..23078fbc407d31b3e40400107a298dc0c2aabb84 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/ae4538d1497e37d21b75a5688827267d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd6b611459ab167e0b3135326fa4b20bfe87bb0f15f9e65040272bde2ddda23c +size 4019 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/b8a6897bfeccd560226850b1a9777223_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/b8a6897bfeccd560226850b1a9777223_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..996ed3ff3d51a45fda76c25c6026c72feabb9e26 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/b8a6897bfeccd560226850b1a9777223_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ae7f2bb4e6a70cb641f66cd41253a51bb502b1c79674a0bc5cb4b6f9d4c552e5 +size 126111 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/c73d23b04412d51220757a916c7dde1a_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/c73d23b04412d51220757a916c7dde1a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cfe355e1502fe308e9fd8fffd8c7897cb97cf2f4 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/c73d23b04412d51220757a916c7dde1a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f0c88c50e14142061c0b37c5704a6073bf2db6a3848fa23ad8d4a16f62df5142 +size 97683 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/d8e29187521d276b76abf37c76d86063_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/d8e29187521d276b76abf37c76d86063_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..669619c962d29bc9aafbdf98931a85dad11d670c --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/d8e29187521d276b76abf37c76d86063_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c360c84654e50c471fecc26b21404036a9559de4560946e6b10300851ef32011 +size 4022 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/f155d271f7d4f77360b3c288064996a7_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/f155d271f7d4f77360b3c288064996a7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cbd8649b86b0330ca277ff0e30e68259b3c078ed --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/f155d271f7d4f77360b3c288064996a7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9dc2e011af75d5c092cd6bcc74a3dce4160514d2f9e747dfadb6d7c81937a37d +size 4108 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/fd4e75af754bdbc8893e8c4a03b0dd53_img.jpg b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/fd4e75af754bdbc8893e8c4a03b0dd53_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f41136f22231f565c838b66f46c15fd6828cdf98 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/fd4e75af754bdbc8893e8c4a03b0dd53_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d7b5412c62d98d23a6d20a1ae212993079c2a0f1c443fc6746012de88e129917 +size 106635 diff --git a/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/raw.md b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..283ff7500ffcc5bab8c744d9e937134fedd6f935 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-GAnP-v01.02/raw.md @@ -0,0 +1,1195 @@ + + +# **O-RAN O2 Interface General Aspects and Principles** --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN O2 Interface General Aspects and Principles** --- + +Copyright © 2022 by the O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in the Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +1 + +# Revision History + +| Date | Revision | Author | Description | +|------------|----------|--------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------| +| 2020.05.29 | 00.01.00 | Joey Moloney (Ericsson)<br>David Kinsey (AT&T)<br>Raghavendra Mahalingappa (Ericsson)<br>Torbjorn Keisu (Ericsson) | Baseline version of General Aspects and Principles Specification<br><br>Content added to Sections 2.1, 3.1, & 3.2 | +| 2020.07.03 | 00.01.01 | Joey Moloney (Ericsson)<br>Raghavendra Mahalingappa (Ericsson) | O2 Introduction added to 2.1 and ETSI information added to 2.5 | +| 2020.07.03 | 00.01.02 | Joey Moloney (Ericsson)<br>Raghavendra Mahalingappa (Ericsson)<br>David Kinsey (AT&T) | O-Cloud Monitoring Service content added to 3.3 | +| 2020.07.03 | 00.01.03 | Joey Moloney (Ericsson)<br>Raghavendra Mahalingappa (Ericsson)<br>David Kinsey (AT&T) | O-Cloud Provisioning content added to 3.4 | +| 2020.07.03 | 00.01.04 | Joey Moloney (Ericsson)<br>Raghavendra Mahalingappa (Ericsson) | O-Cloud Software Management content added to 3.5 | +| 2020.07.03 | 00.01.05 | Joey Moloney (Ericsson)<br>Raghavendra Mahalingappa (Ericsson)<br>Udi Schwager (Wind River) | O-Cloud LCM content added to 3.6 | +| 2020.07.03 | 00.01.06 | Joey Moloney (Ericsson)<br>Raghavendra Mahalingappa (Ericsson) | O-Cloud Deployment LCM content added to 3.7 | +| 2020.07.07 | 00.01.07 | David Kinsey (AT&T) | Deployment definition added to 1.3.1 | +| 2020.07.10 | 00.01.08 | Joey Moloney (Ericsson) | Updated based on review comments | +| 2020.07.17 | 00.01.09 | Joey Moloney (Ericsson) | Updated based on further review comments | +| 2020.07.29 | 01.00.00 | Joey Moloney (Ericsson)<br>Lucian Suci (Orange) | Approved version for publication | +| 2021.06.22 | 01.00.01 | Joey Moloney (Ericsson) | Fault concepts content added to 3.5.2 | +| 2021.06.22 | 01.00.02 | Joey Moloney (Ericsson) | DMS clarification content added to 2.2.1 and Annex A (Informative): O-Cloud and IMS Initialization | +| 2021.07.02 | 01.00.03 | Joey Moloney (Ericsson) | Updated to align with 3GPP specification and to include comments received | +| 2021.07.05 | 01.00.04 | Joey Moloney (Ericsson) | Correction to the incorrect statement about the smallest resource | + +| | | | | +|------------|----------|-------------------------|-------------------------------------------------------------------| +| 2021.11.15 | 01.01.01 | Joey Moloney (Ericsson) | DMS Principles content updated in 3.7 and sub-section 3.7.2 added | +| 2021.11.15 | 01.01.02 | Joey Moloney (Ericsson) | Performance concepts content added to 3.5.3 | +| 2021.11.15 | 01.01.03 | Joey Moloney (Ericsson) | O-Cloud Provisioning concepts added to 3.4.3 | + +# Table of Contents + +| | | | +|----|-------------------------------------------------------------------------|----| +| 1 | Revision History..... | 2 | +| 2 | Chapter 1. Introduction..... | 7 | +| 3 | 1.1 Scope ..... | 7 | +| 4 | 1.2 References..... | 7 | +| 5 | 1.3 Definitions and Abbreviations ..... | 8 | +| 6 | 1.3.1 Definitions..... | 8 | +| 7 | 1.3.2 Abbreviations ..... | 8 | +| 8 | Chapter 2. General Aspects ..... | 10 | +| 9 | 2.1 Introduction to O2..... | 10 | +| 10 | 2.2 Alignment with O-RAN Architecture..... | 10 | +| 11 | 2.2.1 Alignment with Overall Architecture ..... | 10 | +| 12 | 2.2.2 Alignment with OAM Architecture ..... | 12 | +| 13 | 2.3 Technology Independence ..... | 12 | +| 14 | 2.4 General Requirements..... | 12 | +| 15 | 2.5 Relationship with Existing Standards and Open Source Solutions..... | 12 | +| 16 | 2.5.1 ETSI NFV ..... | 13 | +| 17 | 2.5.2 IETF ..... | 14 | +| 18 | 2.5.3 3GPP ..... | 14 | +| 19 | 2.5.4 Kubernetes ..... | 14 | +| 20 | 2.5.5 OpenStack ..... | 14 | +| 21 | 2.5.6 ONAP/OSM ..... | 14 | +| 22 | Chapter 3. O2 Interface General Principles..... | 15 | +| 23 | 3.1 O-Clouds..... | 15 | +| 24 | 3.2 O-Cloud Inventory..... | 16 | +| 25 | 3.2.1 Infrastructure Inventory..... | 16 | +| 26 | 3.2.2 Logical Inventory ..... | 16 | +| 27 | 3.2.3 Deployment Inventory..... | 17 | +| 28 | 3.3 O-Cloud Monitoring Service ..... | 17 | +| 29 | 3.3.1 General Capabilities ..... | 18 | +| 30 | 3.4 O-Cloud Provisioning ..... | 19 | +| 31 | 3.4.1 Affinity, Anti-Affinity, Quorum Diversity Rules..... | 19 | +| 32 | 3.4.2 O-Cloud Capacity and Availability ..... | 20 | +| 33 | 3.4.3 O-Cloud Provisioning Basic Concepts..... | 20 | +| 34 | 3.5 O-Cloud Software Management ..... | 26 | +| 35 | 3.5.1 General Capabilities ..... | 27 | +| 36 | 3.5.2 O-Cloud Fault Management Concepts ..... | 27 | +| 37 | 3.5.3 O-Cloud Performance Basic Concepts..... | 31 | +| 38 | 3.6 O-Cloud Life Cycle Management..... | 33 | +| 39 | 3.7 O-Cloud Deployment Life Cycle Management ..... | 34 | +| 40 | 3.7.1 General Capabilities ..... | 35 | +| 41 | 3.7.2 Deployment Management Services..... | 35 | +| 42 | Annex A (Informative): O-Cloud and IMS Initialization..... | 36 | +| 43 | UML sequence diagram for O-Cloud and IMS initialization ..... | 36 | +| 44 | Annex ZZZ O-RAN Adopter License Agreement..... | 37 | +| 45 | Section 1: DEFINITIONS ..... | 38 | +| 46 | Section 2: COPYRIGHT LICENSE..... | 38 | +| 47 | Section 3: FRAND LICENSE..... | 38 | +| 48 | Section 4: TERM AND TERMINATION ..... | 39 | +| 49 | Section 5: CONFIDENTIALITY ..... | 39 | +| 50 | Section 6: INDEMNIFICATION ..... | 39 | +| 51 | Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 39 | +| 52 | Section 8: ASSIGNMENT ..... | 40 | +| 53 | Section 9: THIRD-PARTY BENEFICIARY RIGHTS ..... | 40 | +| 54 | Section 10: BINDING ON AFFILIATES ..... | 40 | +| 55 | | | + +| | | | +|---|---------------------------|----| +| 1 | Section 11: GENERAL ..... | 40 | +| 2 | | | + +# Table of Figures + +| | | | +|----|---------------------------------------------------------------------------|----| +| 1 | | | +| 2 | Figure 2.2-1 O-Cloud IMS and DMS Relationships to SMO ..... | 10 | +| 3 | Figure 2.2-2 O2 RP Service Based-Interfaces ..... | 11 | +| 4 | Figure 3.1-1 O-Cloud Planes ..... | 15 | +| 5 | Figure 3.2-1 O-Cloud Infrastructure Inventory..... | 16 | +| 6 | Figure 3.2-2 Logical Clouds ..... | 17 | +| 7 | Figure 3.3-1 Telemetry Types ..... | 18 | +| 8 | Figure 3.4-1 Diagram of kinds of Resources and examples of Resources..... | 21 | +| 9 | Figure 3.5-1 Parallel Reporting & Alarm Correlation ..... | 30 | +| 10 | Figure 3.5-2 Concept of Fault Domains ..... | 31 | +| 11 | Figure 3.7-1 O2 Deployment LCM Services ..... | 35 | +| 12 | | | + +# Chapter 1. Introduction + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG6 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +This document defines O-RAN O-Cloud OAM interface functions and protocols for the O-RAN O2 interface. The document studies the functions conveyed over the interface, including management functions, procedures, operations and corresponding solutions, and identifies existing standards and industry work that can serve as a basis for O-RAN work. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 16. + +- [1] 3GPP TR 21.905: “3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Vocabulary for 3GPP Specifications” +- [2] O-RAN Architecture Description Version 2.0 +- [3] O-RAN Operations and Maintenance Architecture Version 3.0 +- [4] O-RAN Operations and Maintenance Interface Version 3.0 +- [5] O-RAN Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN Version 2.1 +- [6] ONAP VES Event Listener Specification version 7.2 – May 2020 +- [7] RFC 6241, “Network Configuration Protocol (NETCONF)”, IETF, June 2011 +- [8] RFC 7950, “The YANG 1.1 Data Modeling Language”, IETF, August 2016 +- [9] SP 800-145, "The NIST Definition of Cloud Computing", NIST, September 2011 +- [10] 3GPP TS 29.501 "5G System; Principles and Guidelines for Services Definition; Stage 3 (Release 16)", September 2020 +- [11] ETSI GS NFV-SOL 013 v3.3.1 "Protocols and Data Models; Specification of common aspects for RESTful NFV MANO APIs", September 2020 +- [12] ETSI GS NFV-SOL 015 v1.1.1 "Protocols and Data Models; Specification of Patterns and Conventions for RESTful NFV-MANO APIs", January 2020 + +- [13] O-RAN Orchestration Use Cases and Requirements for O-RAN Virtualized RAN Version 2.1 +- [14] 3GPP TS28.550 Management and orchestration; Performance assurance Version 17 +- [15] 3GPP TS28.531 Management and orchestration; Provisioning Version 17 +- [16] ETSI SOL003 Zero-touch network and Service Management (ZSM); End-to-end management and orchestration of network slicing + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +- NF Deployment:** An O-Cloud NF Deployment is a deployment of a cloud native Network Function (all or partial), resources shared within a NF Function, or resources shared across network functions. The NF Deployment configures and assembles user-plane resources required for the cloud native construct used to establish the NF Deployment and manage its life cycle from creation to deletion. +- NF Deployment Descriptor:** A completed data model which provides an O-Cloud the necessary information to create a deployment. +- Deployment ID:** Correlation Identity created by the O-Cloud for the SMO to relate to its inventory and manage. +- Deployment Management Services (DMS):** +- The DMS are the logical services provided by the O-Cloud providing for managing the life cycle of deployments which use cloud resources. +- Federated O-Cloud Orchestration and Management (FOCOM):** +- The SMO treats the collection of O-Clouds as a single federated cloud. The FOCOM are the logical services provided by the SMO to manage the distribution of O-Cloud software and provides orchestration for O-Cloud life cycle processes. +- Infrastructure Management Services (IMS):** +- The IMS are the logical services provided by the O-Cloud which provides the interface to orchestrate O-Cloud life cycle processes with the network functions it may be hosting and other operational procedures. +- Network Function Orchestration (NFO):** +- The NFO are the logical services of the SMO which coordinates between the O-Cloud for managing deployment life cycle events, open loop, and closed loop operational procedures. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in 3GPP TR 21.905 [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [1]. + +| | | +|---------|---------------------------------------------------------| +| FCAPS | Fault, Configuration, Accounting, Performance, Security | +| HATEOAS | Hypermedia as the Engine of Application State | +| MANO | Management and Orchestration | +| MnS | Management Service | +| MOC | Managed Object Class | +| MOI | Managed Object Instance | +| O-RAN | Open Radio Access Network | +| ONAP | Open Network Automation Platform | + +| | | | +|---|-----|--------------------------------------| +| 1 | OSM | Open Source Mano | +| 2 | RAN | Radio Access Network | +| 3 | TR | Technical Report | +| 4 | TS | Technical Specification | +| 5 | SMO | Service Management and Orchestration | + +# Chapter 2. General Aspects + +## 2.1 Introduction to O2 + +The O2 interface is an open logical interface within O-RAN architecture providing secured communication between the SMO and O-Cloud. It enables the management of O-Cloud infrastructures and the deployment life cycle management of O-RAN cloudified NFs that run on O-Cloud. The O2 interface is defined in an extensible way that enables new information or functions to be added without necessarily needing to change the protocol or the procedures. This interface enables a multi-vendor environment and is independent of specific implementations of the SMO and O-Cloud. + +## 2.2 Alignment with O-RAN Architecture + +This section provides any added detail not found in the high-level O-RAN architecture documents which define and describe the O2 interface. The intent is to extend knowledge and not to redefine existing information. Therefore, if a conflict exists between this document and the O-RAN Architecture Description [2] or the O-RAN OAM Architecture [3] the information presented will not supersede those documents. + +### 2.2.1 Alignment with Overall Architecture + +This document adopts the architecture as described in the O-RAN Architecture Description [2]. The O2 is described as the interface between the SMO and the O-Cloud to provide platform resources and workload management. + +The O-Cloud needs to be created before the SMO can interface with it. + +O-Cloud can consist of multiple Deployment Management Services. Each DMS can manage leased resources from multiple resource pools and span multiple locations. There is a single IMS for O-Cloud that manages all resources of DMSes as well as resources that are not allocated to any DMS in the O-Cloud. Diagram below depicts relationship between SMO and components of O-Cloud. + +#### O-Cloud IMS & DMS relationships to SMO + +![Diagram illustrating O-Cloud IMS & DMS relationships to SMO. The SMO (Service Management & Orchestration) is at the top, containing NFO and FOCOM. NFO connects to multiple DMS (Deployment Management Services) and IMS (Integration Management Services) within the O-Cloud. FOCOM connects to DMS and IMS. The O-Cloud is divided into two main sections: 'O-Cloud' (left) and 'O-Cloud' (right). The left section shows DMS instances with 'Resource Lease' blocks, connected to 'IMS owned and managed' resources, which are further divided into 'Resource Pools' (e.g., Resource Pool 1 @ Location X, Resource Pool 2 @ Location Y, Resource Pool 3 @ Location Z, Resource Pool n @ Location Z) and 'Physical Resources'. The right section shows a single DMS instance connected to an IMS, which is also connected to 'Physical Resources'.](26783e25c9c3af602e9cb84a79442729_img.jpg) + +Diagram illustrating O-Cloud IMS & DMS relationships to SMO. The SMO (Service Management & Orchestration) is at the top, containing NFO and FOCOM. NFO connects to multiple DMS (Deployment Management Services) and IMS (Integration Management Services) within the O-Cloud. FOCOM connects to DMS and IMS. The O-Cloud is divided into two main sections: 'O-Cloud' (left) and 'O-Cloud' (right). The left section shows DMS instances with 'Resource Lease' blocks, connected to 'IMS owned and managed' resources, which are further divided into 'Resource Pools' (e.g., Resource Pool 1 @ Location X, Resource Pool 2 @ Location Y, Resource Pool 3 @ Location Z, Resource Pool n @ Location Z) and 'Physical Resources'. The right section shows a single DMS instance connected to an IMS, which is also connected to 'Physical Resources'. + +**Figure 2.2-1 O-Cloud IMS and DMS Relationships to SMO** + +SMO can utilize blueprints or other pre-configuration templates to assign resources to resource pools and to assign resource to a DMS. + +Once the O-Cloud is operational the O-RAN Architecture Description [2] describes the functions to be performed over the O2 interfaces as: + +- O-Cloud Infrastructure Resource Management: + - O-Cloud infrastructure Discovery and administration + - O-Cloud infrastructure Scale-In, Scale-Out + - O-Cloud infrastructure FCAPS (PM, CM, FM, Communication Surveillance) + - O-Cloud infrastructure Platform Software Management +- Managing Abstracted Resources and DMSes: + - Creation, Scale-In, Scale-Out of abstracted assigned O-Cloud infrastructure resources + - Deployment FCAPS (PM, FM) for abstracted O-Cloud infrastructure resources + - Deployment DMS (Creation, Deletion and Lease of O-Cloud infrastructure) +- NF & Services Deployment Orchestration + - Deployment Software Management + - Deployment, Termination, Scaling, and Healing of NF & Services deployment resources + - FCAPS (PM, FM) for NF & Services deployment resources + +These functions fall into 3 categories: managing infrastructure, managing abstract resource and DMSes, and managing NF & Services life-cycle on the DMSs. + +These functions can be divided into two classes. Those which manage the infrastructure and those which manage deployments on that infrastructure. Therefore, the O-Cloud is logically composed of two functional blocks. The SMO has two logical blocks for the consumers of the O-Cloud services. The O2 as a Reference Point (RP) described in [10] are thus broken down into two (2) Service Based Interfaces (SBI) this decomposition is depicted in Figure 2.2-2 O2 RP Service Based-Interfaces. + +![Figure 2.2-2 O2 RP Service Based-Interfaces diagram. The diagram shows the Service Provider Functionality (SMO) separated from the O-Cloud by a dashed line representing the O2 interface. The SMO contains three main components: Federated O-Cloud Orchestration and Management (FOCOM), Network Function Orchestrator (NFO), and OAM Function. The O-Cloud contains two main components: Infrastructure Management Services (IMS) and Deployment Management Services (DMS). The O2 interface is split into two parts: O2ims (connecting FOCOM to IMS) and O2dms (connecting NFO and OAM Function to DMS). A yellow callout box points to the dashed line with the text 'Separation of Concerns boundary'.](4e22ba1478b757619acc621afb48546a_img.jpg) + +Figure 2.2-2 O2 RP Service Based-Interfaces diagram. The diagram shows the Service Provider Functionality (SMO) separated from the O-Cloud by a dashed line representing the O2 interface. The SMO contains three main components: Federated O-Cloud Orchestration and Management (FOCOM), Network Function Orchestrator (NFO), and OAM Function. The O-Cloud contains two main components: Infrastructure Management Services (IMS) and Deployment Management Services (DMS). The O2 interface is split into two parts: O2ims (connecting FOCOM to IMS) and O2dms (connecting NFO and OAM Function to DMS). A yellow callout box points to the dashed line with the text 'Separation of Concerns boundary'. + +**Figure 2.2-2 O2 RP Service Based-Interfaces** + +The following are a description of the functional blocks identified in Figure 2.2-2 O2 RP Service Based-Interfaces. + +- **Federated O-Cloud Orchestration and Management (FOCOM):** The FOCOM is responsible for accounting and asset management of the resources in the cloud. The FOCOM is the primary consumer of services provided by the IMS. The FOCOM has information about the O-Cloud resources management. Specifically, the FOCOM needs to know whether the services are within the operator domain or external. +- **Network Function Orchestrator (NFO):** The NFO is responsible for orchestrating the assembly of the network functions as a composition of NF Deployments in the O-Cloud. It may also utilize OAM Functions in order to access the O1 interface to the NF once it is deployed. Its use of the O1 is not germane to the O2 and is only mentioned here for completeness. The NFO is the primary consumer of the DMS. +- **OAM Functions:** The OAM Functions are responsible for FCAPS management of O-RAN managed entities. In the context of O2 they may be one of the functional blocks for which a callback is provided in order to receive faults and/or performance data from a subscription for O2ims or O2dms procedures. + +- **Infrastructure Management Services (IMS):** The IMS is responsible for management of the O-Cloud resources and the software which is used to manage those resources. The IMS generally provides services for consumption by the FOCOM. +- **Deployment Management Services (DMS):** The DMS is responsible for management of NF Deployments into the O-Cloud. It provides the ability to instantiate, monitor, and terminate NF Deployments. The DMS generally provides services for consumption by the NFO. + +### 2.2.2 Alignment with OAM Architecture + +This document adopts the O-RAN OAM architecture defined in [3], including the principles, requirements and reference architecture. It provides added detail on the use of the O2 Interface and associated functional blocks within SMO and O-Cloud. + +## 2.3 Technology Independence + +The intent of this specification is to keep it open and extensible such that it can adapt over time to technology not yet available. Therefore, functionality is described or cited with the intent to leverage open standards. There is a preference to reuse existing standards or open approaches such as Kubernetes and OpenStack. + +## 2.4 General Requirements + +The requirements below may be superceded in the O2 Specification as the interface evolves. + +| Requirement ID | Requirement | Description | +|------------------------|-------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------| +| REQ-O2-GEN-SMO-FUN-1 | All SMOs (e.g., ONAP, OSM, etc.) shall support the O2 services and their requirements allocated to the role of the SMO. | SMO supports O2. | +| REQ-O2-GEN-OC-FUN-1 | All O-Cloud implementations shall support the O2 services and their requirements allocated to the role of the O-Cloud. | O-Cloud supports O2. | +| REQ- O2-GEN-TLS-FUN-1 | Management Service providers and consumers that use TLS shall support TLS v1.2 or higher. | Communications between SMO and O-Cloud are secure. | +| REQ- O2-GEN-HTTP-FUN-1 | Management Service providers and consumers that use HTTP shall support HTTP v1.1 or higher. | HTTP minimum is v1.1. | + +## 2.5 Relationship with Existing Standards and Open Source Solutions + +The O-RAN O2 O-Cloud management services follow existing standards wherever possible. The focus of this document is to identify the use cases which conform to existing standards, identify gaps in management services for O-RAN and define needed extensions. For identified gaps, the goal is to modify the standards to include the needed O-RAN extensions and update the references in this document as the standards evolve to cover the gaps. If extensions and gaps are not specified, it is expected that the management services producers and consumers are conforming to referenced specifications. + +### 2.5.1 ETSI NFV + +This is a list of the relevant ETSI NFV standards documents which require evaluation in order to analyze packaging, LCM operations, and security for managing VMs and Containers, the versions will be specified in the O2 Specification: + +- SOL004 standard is used for VNF and PNF packages +- SOL007 standard is used for NS package +- SOL001 standard is used to describe VNF, PNF, and NS in TOSCA +- SOL003 standard is used for VNF Package Management, LCM and Monitoring +- SOL005 standard is used for NS/PNF/VNF Package Management, LCM and Monitoring +- SOL006 standard is used to describe VNF, PNF, and NS in YANG +- SOL002 standard is used for VNF/VNFC-level EM triggered scenarios (LCM, Fault, Performance, Configuration) +- ETSI Package and communication security are supported / API security are supported (SEC022 GS) +- IFA 029 Enhancements of the NFV architecture towards "Cloud-native" and "PaaS" +- IFA040 CISM OS container compute management service interface requirements (ongoing) +- ETSI IFA 005/006 covers topics Software Image Management, Virtual Resource Management (Information, Quota, Capacity, Change Notification, and Reservation) Virtual Resource Performance Management, Virtual Resource Fault Management and NFP + +The O2 interfaces will generally follow ETSI GS NFV-SOL 013 [11] section 8 for interface security. Further refinements will be based on recommendations from the STG and are FFS. + +Other sections of SOL 13 [11] are still under review and are therefore FFS. + +NFV SOL-015 [12] provides RESTful Patterns. Section 5.9 defines the Subscribe-Notify pattern. Generally, this pattern is adopted by the O2, with the following caveats. + +- Notifications should indicate success or failure of the receipt of the notification to the notifying function. +- The subscribe and POST may not be in the same service API. The typical pattern for the O2 is that the subscribe, or its equivalent, is in the O-Cloud services and the post for the notification is an SMO service. There are no existing use cases of notifications from the SMO to the O-Cloud. +- The event types may be extended over time. Therefore, the O-Cloud services should provide the ability to discover what event types the cloud instance supports. The minimal list of supported event types SHALL be: + - Inventory Change + - Configuration Change + - Fault Events + - Performance Reporting + - Heartbeat + +Another form of notification is the callback mechanism where the notify function is identified in the request. This mechanism is used in platform the software update procedure, as the cloud may not yet be configured for notifications when the update occurs. It is expected that all subscriptions and identified callbacks are persisted through a restart or a software update. + +#### 1 2.5.2 IETF + +2 For Future Study. + +#### 3 2.5.3 3GPP + +4 The O2 interface is composed of services provided by the SMO and service provided by the O-Cloud. This closely +5 resemble the Reference Points and Service Based Interface (SBI) definitions described in 3GPP TS 29.501[10]. Therefore, +6 this specification follows the intent of the practices defined in [10] but has modified it from its intended 5G Core +7 implementation to align with the O-RAN O2 interface. + +#### 8 2.5.4 Kubernetes + +9 For Future Study. + +#### 10 2.5.5 OpenStack + +11 For Future Study. + +#### 12 2.5.6 ONAP/OSM + +13 For Future Study. + +# Chapter 3. O2 Interface General Principles + +This section describes the general approach to solving common problems with managing a cloud and the deployments which execute on it. + +## 3.1 O-Clouds + +O-RAN clouds are described in [5] as a distributed cloud composed of O-Cloud [Resource] Pools (as shown as white clouds in the diagram below) where each pool is a collection of O-Cloud Nodes at a specific location. An O-Cloud Node is the basic computational resource designator and can be commonly thought of as a server. An Operator may have several O-Clouds from different vendors but will manage them as a single entity. These O-Clouds are viewed by the Service Management and Orchestration (SMO) Framework as a Federated O-Cloud. + +O-Cloud Nodes are provisioned into resources which are assigned for a specific use by the O-Cloud Management Software according to a blueprint. As a general concept the cloud is divided into three planes, however the control and management plane described below may be merged or use common tools and therefore may act as or be one plane. + +- Management Plane: O-Cloud Nodes in this plane host the software which is responsible for managing the O-Cloud +- Control Plane: O-Cloud Nodes in this plane are responsible for hosting the software which manages the resources assigned in the deployment plane to specific deployment instances +- Deployment Plane: O-Cloud Nodes in this plane are used to host "Service Model" Deployments + +![Diagram of O-Cloud Planes showing three stacked layers: Management Plane (green), Control Plane (yellow), and Deployment Plane (orange). The diagram illustrates various implementation types: Medium Regional Implementations, Dedicated to a Plane, Shared Across Planes, Small Edge Implementations, Large Central Implementations, and Distributed Geography. Each plane contains server icons representing O-Cloud Nodes.](a4e76fc9633751a306acb4185ae59f5a_img.jpg) + +The diagram illustrates the O-Cloud architecture across three planes: Management Plane (top, green), Control Plane (middle, yellow), and Deployment Plane (bottom, orange). The background shows a world map. Various implementation types are indicated by blue callout boxes with arrows pointing to specific server stacks (O-Cloud Nodes): + +- Medium Regional Implementations:** Points to a server stack in the Management Plane. +- Dedicated to a Plane:** Points to a server stack in the Control Plane. +- Shared Across Planes:** Points to a large stack of servers spanning the Control and Deployment Planes. +- Small Edge Implementations:** Points to a server stack in the Deployment Plane. +- Large Central Implementations:** Points to a large stack of servers in the Deployment Plane. +- Distributed Geography:** Points to a server stack in the Deployment Plane. + +Diagram of O-Cloud Planes showing three stacked layers: Management Plane (green), Control Plane (yellow), and Deployment Plane (orange). The diagram illustrates various implementation types: Medium Regional Implementations, Dedicated to a Plane, Shared Across Planes, Small Edge Implementations, Large Central Implementations, and Distributed Geography. Each plane contains server icons representing O-Cloud Nodes. + +Figure 3.1-1 O-Cloud Planes + +## 3.2 O-Cloud Inventory + +From the perspective of the SMO, O-Cloud Inventory consists of the physical infrastructure used to create the O-Cloud, the logical clouds which it provides as interfaces for deployments, and the inventory of deployments using the logical cloud. The SMO is responsible for financial accounting of physical inventory. The SMO inquires about the mapping of resources to their use. The O-Cloud is responsible for the assignment of resources to their use. + +### 3.2.1 Infrastructure Inventory + +Infrastructure inventory is passed between the SMO and the O-Cloud over the O2ims. An O-Cloud Node Identifier is used to correlate the inventory. This identifier needs to be discoverable by the O-Cloud and would likely be on an invoice for the O-Cloud purchase order. The O-Cloud Node Identifier must be immutable. + +The IMS will add O-Cloud Nodes to the relevant O-Cloud Resource Pools when they are powered on and ready to be provisioned as a resource. The IMS then allocates them to a plane according to its policies and sends the O-Cloud Node characteristics to the SMO. + +The SMO receives O-Cloud Node startup events and updates its inventory accordingly. The O-Cloud Node Identifier is matched with invoice data in order to provide financial asset tracking requirements. The location and use identifiers are used to track inventory which will be monitored as part of cloud service assurance. + +![Figure 3.2-1 O-Cloud Infrastructure Inventory diagram. The diagram shows a hierarchical structure. At the top is a light blue box labeled 'Service Provider Functionality' containing a darker blue box labeled 'FOCOM'. Below this is a dashed horizontal line. Underneath the dashed line are three green boxes, each labeled 'Cloud Provider Functionality'. Inside each green box is a smaller dark green box labeled 'O2 Cloud Provider Infrastructure Management Services'. Above each green box, the text 'O2ims' is written with a vertical line connecting it to the box. To the left of the first green box, an orange arrow points upwards, labeled 'Physical/Logical Inventory'. To the right of the last green box, an orange arrow points downwards, labeled 'Maintenance Schedules'.](9dc9fca8fa1974acc47c7c9320cc655a_img.jpg) + +Figure 3.2-1 O-Cloud Infrastructure Inventory diagram. The diagram shows a hierarchical structure. At the top is a light blue box labeled 'Service Provider Functionality' containing a darker blue box labeled 'FOCOM'. Below this is a dashed horizontal line. Underneath the dashed line are three green boxes, each labeled 'Cloud Provider Functionality'. Inside each green box is a smaller dark green box labeled 'O2 Cloud Provider Infrastructure Management Services'. Above each green box, the text 'O2ims' is written with a vertical line connecting it to the box. To the left of the first green box, an orange arrow points upwards, labeled 'Physical/Logical Inventory'. To the right of the last green box, an orange arrow points downwards, labeled 'Maintenance Schedules'. + +Figure 3.2-1 O-Cloud Infrastructure Inventory + +### 3.2.2 Logical Inventory + +The SMO will need to know the composition of an ME in terms of its MFs as described in the O-RAN OAM Architecture [3]. This cannot be derived from the deployments and therefore is not addressed by the O2 interface. This data should be contained in the ME configuration and should be collected over the O1 interface [4]. + +The O-Cloud itself must have one or more DMS available within its distributed footprint. These could be based on virtual technologies (Kubernetes/Docker, Open Stack, etc.) used, and/or O-Cloud pool locations. Each DMS endpoint provides an O2dms interface and is inventoried by the SMO as a logical cloud. The logical cloud is used by the SMO in order to select the O-Cloud to be used for a deployment during the cloud selection process. + +![Figure 3.2-2 Logical Clouds diagram. The diagram shows a Service Provider Functionality layer at the top, containing an NFO (Network Function Orchestrator) block. Below this is a dashed line representing a 'Separation of Concerns boundary'. Underneath the boundary are two main sections: 'Cloud Provider Functionality' on the left and 'Cloud Provider Functionality' on the right. The left section contains 'O2 OpenStack DMS Plug In' and 'O2 Kubernetes DMS Plug In', with a 'Resource Pool Location' cloud icon below them. The right section contains 'O2 Hybrid Location 2 DMS Plug In' and 'O2 Hybrid Location 3 DMS Plug In', with 'Resource Pool Location 2' and 'Resource Pool Location 3' cloud icons below them. A yellow callout box points to the NFO, stating: '2 O-Cloud Instances with a total of 3 Resource Pools look like 4 logical clouds to the SMO for VNF Homing and NF Orchestration'. Another yellow callout box points to the dashed line, stating: 'Separation of Concerns boundary'. A third yellow callout box points to the 'O2 Hybrid Location 2 DMS Plug In' and 'O2 Hybrid Location 3 DMS Plug In' blocks, stating: 'Plug In end point appears as logical cloud to NFO'. A fourth yellow callout box points to the 'Resource Pool Location 2' and 'Resource Pool Location 3' cloud icons, stating: 'Resource Pool with a global unique location ID'. A fifth yellow callout box points to the 'O2 OpenStack DMS Plug In' and 'O2 Kubernetes DMS Plug In' blocks, stating: 'Homing Policy and Cloud Capabilities match Descriptor types with O2-D endpoint'. A sixth yellow callout box points to the 'Resource Pool Location 2' and 'Resource Pool Location 3' cloud icons, stating: 'Distributed O-Cloud Instance'.](2b5e58ee3c15a7bc83d13dd765d6410f_img.jpg) + +Figure 3.2-2 Logical Clouds diagram. The diagram shows a Service Provider Functionality layer at the top, containing an NFO (Network Function Orchestrator) block. Below this is a dashed line representing a 'Separation of Concerns boundary'. Underneath the boundary are two main sections: 'Cloud Provider Functionality' on the left and 'Cloud Provider Functionality' on the right. The left section contains 'O2 OpenStack DMS Plug In' and 'O2 Kubernetes DMS Plug In', with a 'Resource Pool Location' cloud icon below them. The right section contains 'O2 Hybrid Location 2 DMS Plug In' and 'O2 Hybrid Location 3 DMS Plug In', with 'Resource Pool Location 2' and 'Resource Pool Location 3' cloud icons below them. A yellow callout box points to the NFO, stating: '2 O-Cloud Instances with a total of 3 Resource Pools look like 4 logical clouds to the SMO for VNF Homing and NF Orchestration'. Another yellow callout box points to the dashed line, stating: 'Separation of Concerns boundary'. A third yellow callout box points to the 'O2 Hybrid Location 2 DMS Plug In' and 'O2 Hybrid Location 3 DMS Plug In' blocks, stating: 'Plug In end point appears as logical cloud to NFO'. A fourth yellow callout box points to the 'Resource Pool Location 2' and 'Resource Pool Location 3' cloud icons, stating: 'Resource Pool with a global unique location ID'. A fifth yellow callout box points to the 'O2 OpenStack DMS Plug In' and 'O2 Kubernetes DMS Plug In' blocks, stating: 'Homing Policy and Cloud Capabilities match Descriptor types with O2-D endpoint'. A sixth yellow callout box points to the 'Resource Pool Location 2' and 'Resource Pool Location 3' cloud icons, stating: 'Distributed O-Cloud Instance'. + +Figure 3.2-2 Logical Clouds + +### 3.2.3 Deployment Inventory + +Although the cloud could support IaaS and PaaS deployments, most O-RAN MEs are composed of SaaS deployments as defined by NIST [9]. The Deployment Descriptor is a set of metadata contained in a datatype matching a capability advertised by the O-Cloud. Logical Cloud selection in the NFO will match the descriptor type with the capability type to enable deployment. The Deployment Descriptor will cause one or more cloud resources to be allocated (VMs, Pods, Containers, Networks) but will return a single correlation ID, referred to here as the Deployment ID. The O-Cloud will provide, over the O2dms, the ability to fetch the details of these objects from their Deployment ID. + +## 3.3 O-Cloud Monitoring Service + +When the O-Cloud Infrastructure or the ORAN cloudified NFs fails, it needs to be fixed immediately, and preferably automatically, to prevent end users from experiencing service disruptions. To avoid this service disruption Network Operations must consider the telemetry information of O-Cloud deployments in the network. The telemetry information serves as a vital resource for analysing the O-Cloud's state and health, and for delivering on service monitoring goals. + +The O-Cloud Monitoring Service uses telemetry data to provide monitoring of O-Cloud infrastructures. The telemetry data is provided by Deployments and Infrastructure and is correlated to reduce duplication of effort in determining the root cause in the network. + +There are different types of telemetry, Managed Element Telemetry, Deployment Telemetry, and Infrastructure Telemetry. + +1. For Managed Element Telemetry, the objective is to monitor the application behaviour. This will be addressed in the O1 Specification [4]. +2. For Deployment Telemetry, the objective is to monitor the number of deployment instances an O-Cloud has at that moment and how many were expected, how the on-progress deployment is going, and health checks. Additional Deployment Telemetry metrics like CPU, network, and memory usage can also be collected. This will be addressed in the O2 Specification. +3. For Infrastructure Telemetry, the objective is to monitor the health of the O-Cloud Infrastructure components. Network Operations are interested in discovering if all the components in the O-Cloud Infrastructure are working properly and at what capacity, how many deployments are running on each node, and the resource utilization of the O-Cloud Infrastructure. This will be addressed in the O2 Specification. + +![Diagram illustrating Telemetry Types. It shows a stack of three layers: Managed Element (top, blue), Deployment (middle, green), and Infrastructure (bottom, yellow). Managed Element contains four 'Deployment' icons (orange circles with gear icons). Deployment contains four server rack icons. Infrastructure contains four server rack icons. Three arrows point left from the layers: 'Managed Element Telemetry' from the top layer, 'Deployment Telemetry' from the middle layer, and 'Infrastructure Telemetry' from the bottom layer.](a504c0bafa604076e995493d21d80e98_img.jpg) + +Diagram illustrating Telemetry Types. It shows a stack of three layers: Managed Element (top, blue), Deployment (middle, green), and Infrastructure (bottom, yellow). Managed Element contains four 'Deployment' icons (orange circles with gear icons). Deployment contains four server rack icons. Infrastructure contains four server rack icons. Three arrows point left from the layers: 'Managed Element Telemetry' from the top layer, 'Deployment Telemetry' from the middle layer, and 'Infrastructure Telemetry' from the bottom layer. + +**Figure 3.3-1 Telemetry Types** + +### 3.3.1 General Capabilities + +#### Business Capabilities: + +- As Network Operations I need telemetry data from Network Functions in order to provide service assurance of the network (Note: This is assumed to be handled by the O1) +- As Network Operations I need telemetry data from the infrastructure in order to provide service assurance of the network +- As Network Operations I need to be able to correlate Network Function Telemetry and Infrastructure Telemetry in order to reduce duplication of effort in determining one root cause + +#### Functional Capabilities: + +- The SMO shall be able to correlate ME telemetry to Infrastructure and Deployment telemetry to aggregate problems to a root cause +- The O-Cloud shall be able to make all Configuration Data and any external changes to it available to the SMO +- O-Cloud telemetry shall minimally consist of Fault, Performance, and Configuration Data +- The SMO shall be able to correlate a Managed Element to its deployment components +- The O-Cloud shall be able to report telemetry of deployment resources relative to those identified in the deployment descriptor +- The O-Cloud shall be able to report Infrastructure telemetry and identify the deployments using the resource +- O-Cloud shall provide the collection and reporting of performance information of O-Cloud resources +- O-Cloud shall support the capability to notify about the availability of performance information +- O-Cloud shall expose the type of performance information that can be collected for the allocated O-Cloud resource(s) +- O-Cloud shall expose the type of O-Cloud resource, for which the performance information can be collected +- O-Cloud shall provide the collection of fault information for O-Cloud resources +- O-Cloud shall support providing notification of fault information related to O-Cloud resources + +## 3.4 O-Cloud Provisioning + +O-Cloud Provisioning is the allocation of O-Cloud's resources and services to an O-RAN Cloudified Network Function. This is one of the key functionalities of the O-Cloud, relating to how an O-RAN Cloudified Network Function procures O-Cloud services and resources. The O-Cloud resources are deployed flexibly to match the O-RAN Cloudified Network Function's fluctuating demands. The O-Cloud resources typically scale up to accommodate spikes in usage and scale down when demands decrease. O-Cloud Provisioning offers numerous benefits including; scalability, speed, and cost saving. + +To support the deployments, O-Cloud Provisioning will need to provide several functionalities. There will be initial support for the following: + +- Affinity, Anti-Affinity, Quorum Diversity Rules +- Capacity Query +- Availability Query + +Support for the following functionalities are FFS: + +- Subscriptions +- Flavor Management +- Server Group Management +- Capabilities Discovery +- Switch Fabric Management +- Quota Management +- Resource Performance Management +- Virtual Resource Performance Management + +### 3.4.1 Affinity, Anti-Affinity, Quorum Diversity Rules + +An Affinity rule specifies that deployments with the same rule applied must be collocated within the same scope. This can be applied to a single server or a server group. Anti-Affinity is the opposite of the Affinity Rule in that deployments with the same rule applied cannot be collocated within the same scope. Affinity and Anti-Affinity rules can be applicable to entities outside of the current deployment such as Tenant or Namespace. + +A Quorum diversity rule stipulates that deployments with this rule can be collocated if less than 50% of the deployments exist within the same scope. This rule can only be enforced when there is a minimum of 3 deployments. In which it will be the same deployment assignment as Anti-Affinity. In scenarios with more than 3 deployments a minimum of 3 different resource assignments at the specified scope (Server or Server Group) will be used. More can be used at the discretion of the O-Cloud Resource Scheduler. + +#### 3.4.1.1 General Capabilities + +Business Capabilities: + +- Network Operations shall be able to apply Affinity, Anti-Affinity, Quorum Diversity rules + +Functional Capabilities: + +- O-Cloud Provisioning shall provide Create rule for Affinity, Anti-Affinity, and Quorum Diversity +- O-Cloud Provisioning shall provide Read rule for Affinity, Anti-Affinity, and Quorum Diversity +- O-Cloud Provisioning shall provide Update rule for Affinity, Anti-Affinity, and Quorum Diversity + +- O-Cloud Provisioning shall provide Delete rule for Affinity, Anti-Affinity, and Quorum Diversity + +### 3.4.2 O-Cloud Capacity and Availability + +O-Cloud Resources are allocated to a DMS for use and each DMS may have a different distribution of Capacity, and Availability. The Capacity is the number of Resources allocated or reserved to an O-Cloud. The Capacity may be larger than the sum of physical resources due to allowed oversubscription in the O-Cloud. The Availability of an O-Cloud is the Capacity minus the allocated and reserved resources. + +#### 3.4.2.1 General Capabilities + +Business Capabilities: + +- Network Operations shall be able to view the Capacity and Availability of an O-Cloud + +Functional Capabilities: + +- O-Cloud Provisioning shall provide Query of O-Cloud Capacity +- O-Cloud Provisioning shall provide Query of O-Cloud Availability + +### 3.4.3 O-Cloud Provisioning Basic Concepts + +These basic concepts will become relevant moving from the traditional RAN paradigm of total network and resource ownership to cloudified networks where there are more stakeholders, and the resources are shared amongst stakeholders. This section will describe basic concepts related to provisioning in the context of IMS and DMS. This section will elucidate that the IMS and DMS have a difference in kind. Provisioning is basic OA&M functionality. The concepts described here will motivate the development of O-Cloud O2 IMS & DMS provisioning service modeling, and information modeling. + +Provisioning in the context of the GA&P is the act of providing access to entities, e.g. resources. + +The general concepts described here relate to O-cloud entities as well as provisioning functionality. The subsections group together like concepts. + +#### 3.4.3.1 Workload + +A workload is any software application(s) that consumes an Abstracted Resource (as defined in this document). + +For example, this workload could be a Host Operating System, Guest Operating System, micro-service, or the software part of a Physical Network Function (PNF), Virtualized Network Function (VNF) or Cloud Native Network Function (CNF) which would typically be deployed by a DMS. + +#### 3.4.3.2 Resource Related Concepts + +##### 3.4.3.2.1 Resource + +A *resource* is defined in a O-cloud infrastructure as one that may be provisioned and managed through an abstraction. O-Cloud infrastructure have two kinds of resources: physical and logical resources. A physical resource is defined as a kindof resource that has a manifestation in the real world. A logical resource is defined as a kindof resource that uses a number of physical resources, or a portion of physical resources, or a number of software entities. A resource can be assigned to an orchestrator that will deploy workloads for resource consumption (see figure 1). + +For example, some kinds of physical resources could be servers, switches, and storage units. + +For example, some kinds of logical resources are Openstack and K8S clusters. + +![Figure 3.4-1 Diagram of kinds of Resources and examples of Resources. The diagram shows three main categories of resources: Managed O-Cloud Service, Logical Resource, and Physical Resource. Each category has a list of examples. Managed O-Cloud Service examples are Boot Service, Upgrade Service, and Management Svc. Logical Resource examples are Container Cluster, OS Cluster, and Underlay Network. Physical Resource examples are Server Hardware, Accelerator HW, and RAN Hardware. The Logical Resource and Physical Resource categories are grouped under 'Resource Pools'.](203e324f8174877a7fbea7ba6e42a54d_img.jpg) + +Figure 3.4-1 Diagram of kinds of Resources and examples of Resources. The diagram shows three main categories of resources: Managed O-Cloud Service, Logical Resource, and Physical Resource. Each category has a list of examples. Managed O-Cloud Service examples are Boot Service, Upgrade Service, and Management Svc. Logical Resource examples are Container Cluster, OS Cluster, and Underlay Network. Physical Resource examples are Server Hardware, Accelerator HW, and RAN Hardware. The Logical Resource and Physical Resource categories are grouped under 'Resource Pools'. + +Figure 3.4-1 Diagram of kinds of Resources and examples of Resources + +##### 3.4.3.2.2 Managed O-Cloud Service + +A Managed O-Cloud Service is an exposed, provisioned, monitorable, or managed entity that performs some operations for a client or consumer. A Managed O-Cloud service is an entity that provides some functionality to other entities. Managed O-Cloud Services could execute on physical and/or logical cloud infrastructure resources thereby consuming cloud infrastructure resources not usable by the O-Cloud. Managed O-Cloud Services could also execute outside of the cloud infrastructure resources. Unlike logical services, Managed O-Cloud Services are created on demand ad infinitum. The IMS is the management endpoint for the Managed O-Cloud Service. + +Note: Exposure means it is visible outside of the IMS through the IMS endpoint as a managed object; thus, the SMO is aware of it. + +For example, an autonomous service as a managed O-Cloud service, which as a plug-in to the cloud that performs some unique functions upon resources. + +For example, some kinds of Managed O-Cloud service might be boot services, upgrade services, and DMS. + +#### 3.4.3.3 Resource Views + +A *Resource View* is defined as the visible and/or accessible part of the Resource that an actor sees based on their authority. Resources are seen by different actors that need to manage or act upon resources. Different perspectives from these actors are “views” of the Resources. O-Clouds can have multiple Resource Views to enable separation of authority and operations of the resources, into logical groups of actors (generally other SW entities). The four kinds of O-Cloud resource views are: *Cloud Infrastructure Resource*, *Abstracted Resources*, *Assigned Resource*, and *Consumed Resource*. This is done to provide maximum separation of concern between different actors. These views accommodate public, external, and shared private cloud deployments. + +For example, Consider a hotel room as a resource. The front desk staff who assigns a room to a tenant has a relationship to the room and job requirements of how to manage the room. That is, they have a “view” of the room. The tenant that checks into the room has a different “*resource view*” of that same room. The cleaning staff has yet another relationship, or “*resource view*”, to the same hotel room. + +![Diagram illustrating Resource Views seen as different actor's perspective. A central purple cube labeled 'RESOURCE' is viewed through four magnifying glasses. The top view is labeled 'Workload' (red circle with a robot icon). The left view is labeled 'FOCOM (SMO)' (yellow circle with a robot icon). The right view is labeled 'NFO (SMO)' (blue circle with a robot icon). The bottom view is labeled 'Infrastructure Manager' (green circle with a robot icon). A callout box on the right states: 'Each actor has a different perspective of the resource'.](713af17dae7cbeca98dc3859534cd979_img.jpg) + +Diagram illustrating Resource Views seen as different actor's perspective. A central purple cube labeled 'RESOURCE' is viewed through four magnifying glasses. The top view is labeled 'Workload' (red circle with a robot icon). The left view is labeled 'FOCOM (SMO)' (yellow circle with a robot icon). The right view is labeled 'NFO (SMO)' (blue circle with a robot icon). The bottom view is labeled 'Infrastructure Manager' (green circle with a robot icon). A callout box on the right states: 'Each actor has a different perspective of the resource'. + +Figure 3.4-2 Resource Views seen as different actor's perspective + +##### 3.4.3.3.1 Cloud Infrastructure Resource View (Green) + +The Cloud Infrastructure Resource view is a resource view of a resource that is managed by Cloud internal physical, software and tool components. Cloud Infrastructure Resource can also be composed of other Cloud Infrastructure Resources and services. These can be used to compose or expose Abstracted Resources. The Cloud Infrastructure Resources are typically provided by the Internal, External or Public Cloud Provider. + +Note: The cloud infrastructure manager (green) is often implemented a different organization than the FOCOM organization (yellow). + +For example, a resource view of the Cloud Infrastructure Resource might have a computer, storage, acceleration, network hardware, and software implementing certain services from a public cloud provider. This is the hardware foundation in any sort of data center that serves as the hardware infrastructure. + +##### 3.4.3.3.2 Abstracted Resource View (Yellow) + +An Abstracted Resource View is a Resource View of a composed Cloud Infrastructure Resource (with a provisioning reference tag) that is offered through Provisioning. Abstracted Resources thereby map underlying cloud infrastructure resources (act of composing). The Abstracted Resource View is a perspective on the actual Abstracted Resources. This abstraction facilitates assigned users to perform their authorized management and LCM operations for the resources. The SMO sends the objectives to the IMS, which are the SMO requirements for Abstracted Resources that are being requested from IMS. See the figure below on "Resource views: abstracted and assigned resources". + +Note: The act of composing a Cloud Infrastructure Resource could be as simple as finding suitable resources and tagging it as an Abstracted Resource. + +For example, an Abstracted Resource View might contain a set of available computer systems and a K8S cluster that are composed by the cloud infrastructure. The Computer Systems are referenced with an abstraction identifier (assigned by the cloud owner) and the underlying physical compute resources are not exposed. The K8S Cluster is also referenced with an abstraction identifier and the underlying compute, network and storage resources are generally not exposed. Some examples of operations on Abstracted Resources include listings of available resources and booking of available resources. For the logical resource e.g., the K8S Cluster other common operations would also include creation, scaling, update, and deletion of the cluster. + +##### 3.4.3.3.3 Assigned Resource View (Blue) + +An Assigned Resource View is a Resource View of an Abstracted Resource provisioned to the SMO that can prepare and adapt the resource(s) for Workload placement and consumption including its related FM and PM interfaces. The IMS assigns resources to the cluster and reports to the SMO. The Assigned Resources are the resources that are requested by an SMO, according to SMO objectives from the pool of Abstracted Resources. When requests are fulfilled, the bookkeeping of Assigned Resources is done by the O-Cloud IMS. See the figure below on “Resource views: abstracted and assigned resources”. + +For example, the Assigned Resource View might present one or many K8S cluster(s) and other kinds of resources as an assigned resource. Some examples of workload orchestration that can be performed on assigned resources are: cluster preparation for the workload, placement (deployment) of workloads, and scaling of the workload on the cluster. + +For example, consider a rental car as a resource. The Vehicle Identification Number (VIN) is associated with the car. The rental company has a rental agreement number for the same car. The person who rents the car has an entitlement according to the rental agreement using the rental agreement number that is not tied to the VIN. In this case, the rental agreement number is a representation of the car as an Abstracted Resource. The renter views the car as an Assigned Resource. At any point in the time, the VIN & agreement number are linked. However, this can change over time. For instance, car #1 breaks down and the rental agreement becomes associated to a new car #2 with a new VIN associated with car #2 all under the same rental agreement number. This illustrates how FOCOM gets Abstracted Resources and hands it to NFO as Assigned Resources. + +##### 3.4.3.3.4 Consumed Resource View (Red) + +Workload Consumed Resources View is a resource view that describes the workloads software program execution in the CPU; acceleration execution in the dedicated HW accelerator; as well as packet classification, manipulation and forwarding in a packet forwarding device. + +For example, the Operating System that consumes CPU instruction resources from the Computer System or Virtual Machine expect to acquire CPU metrics based on information to its OS drivers to offer its built-in performance management services e.g., the common OS TOP commands that indicates how the CPU resources are consumed. + +![Figure 3.4-2 Resource Views – Abstracted & Assigned Resources. The diagram illustrates the flow of resource management within the Service Management Orchestrator (SMO). At the top, the SMO contains FOCOM and NEO components. FOCOM sends 'Assignments' to NEO. FOCOM also sends 'Objectives' to the IMS (Integrated Management System). The IMS provisions 'Abstracted Resources' from a 'Resource Pool' containing 'Physical Resource', 'Logical Resource', and 'Managed O-Cloud Service'. These are then sent via 'Cluster Creation' to the DMS (Data Management System), which prepares, places, and scales workloads on the assigned resources. The DMS also receives direct input from NEO.](b8a6897bfeccd560226850b1a9777223_img.jpg) + +``` + +graph TD + subgraph SMO [Service Management Orchestrator (SMO)] + FOCOM((FOCOM)) -- Assignments --> NEO((NEO)) + end + FOCOM -- Objectives --> IMS + subgraph IMS_Box [IMS] + IMS_Label[IMS] + IMS_Text[Provisioning Abstracted resources] + AR[Abstracted Resources] + RP[Resource Pool] + PR[Physical Resource] + LR[Logical Resource] + MOS[Managed O-Cloud Service] + end + subgraph DMS_Box [DMS] + DMS_Label[DMS] + DMS_Text[Prepare, Place, Scale workloads on assigned resources] + AR2[Assigned Resources] + end + RP -- Cluster Creation --> AR2 + NEO --> DMS_Label + +``` + +Figure 3.4-2 Resource Views – Abstracted & Assigned Resources. The diagram illustrates the flow of resource management within the Service Management Orchestrator (SMO). At the top, the SMO contains FOCOM and NEO components. FOCOM sends 'Assignments' to NEO. FOCOM also sends 'Objectives' to the IMS (Integrated Management System). The IMS provisions 'Abstracted Resources' from a 'Resource Pool' containing 'Physical Resource', 'Logical Resource', and 'Managed O-Cloud Service'. These are then sent via 'Cluster Creation' to the DMS (Data Management System), which prepares, places, and scales workloads on the assigned resources. The DMS also receives direct input from NEO. + +Figure 3.4-2 Resource Views – Abstracted & Assigned Resources + +#### 3.4.3.4 Hardware Layer Concepts + +##### 3.4.3.4.1 Computer System + +A Computer System is defined to be a physical or composed system capable of perform computations that is Underlay-Network connected. A Computer System can run any major Operating System with or without Virtualization and/or Container support functionality. See diagram 4: “Hardware Layer Concepts” + +Note: A computer system in the context of a cloudified network and usage in cluster requires a network connectivity. + +For example, a server in a data center connected to an underlay network. + +![Figure 3.4-3 Hardware Layer Concepts diagram. The diagram shows a hierarchical hardware layer structure. At the top is a light blue rounded rectangle labeled 'Computer Systems' with two server icons. Below it is a light yellow rounded rectangle labeled 'Underlay Network' with a network switch icon. A blue line connects the 'Underlay Network' to the 'Computer Systems'. To the right of the 'Underlay Network' is a blue rounded rectangle labeled 'Gateway' with a router icon. A blue line connects the 'Underlay Network' to the 'Gateway'.](6c31df96b5bf6162ebdb452fcee9d3e2_img.jpg) + +Figure 3.4-3 Hardware Layer Concepts diagram. The diagram shows a hierarchical hardware layer structure. At the top is a light blue rounded rectangle labeled 'Computer Systems' with two server icons. Below it is a light yellow rounded rectangle labeled 'Underlay Network' with a network switch icon. A blue line connects the 'Underlay Network' to the 'Computer Systems'. To the right of the 'Underlay Network' is a blue rounded rectangle labeled 'Gateway' with a router icon. A blue line connects the 'Underlay Network' to the 'Gateway'. + +Figure 3.4-3 Hardware Layer Concepts + +##### 3.4.3.4.2 Underlay Network + +An underlay network is a physically connected network enabling Computer Systems to communicate with each other and with the gateway(s) connected to networks outside of the data center. + +#### 3.4.3.5 Execution Environment Layer Concepts + +##### 3.4.3.5.1 Operating System (OS) + +An Operating system is System software that manages and abstracts the Computer System hardware and software resources as well as provides common services for computer programs such as scheduling and network connectivity. + +##### 3.4.3.5.2 Operating System with Virtual Machines + +An Operating System with Virtual Machines is an OS that through software or hardware implementation includes the ability to offer multiple Virtual Machines, each acting as a well-separated Computer System. + +##### 3.4.3.5.3 Operating System with Containers + +An Operating System (OS) with Containers is an OS that include the ability to offer multiple separated name spaces, quotas, and management for Containers. + +##### 3.4.3.5.4 Compute Node + +A Compute Node is a Computer System with a running managed Operating System that is network connected. This is Cloud infrastructure internal representation that could be manifested as an O-Cloud Node once exposed over O2ims as an Abstracted Resource. (CAD definition: “An O-Cloud Node is a collection of CPUs, Mem, Storage, NICs, Accelerators, BIOSes, BMCs, etc., and can be thought of as a server.”). + +##### 3.4.3.5.5 Overlay Network + +An Overlay Network is a logical network interconnect enabling Compute Nodes to communicate with each other within their Cluster and with the gateway(s) connected to networks outside of the data center. + +##### 3.4.3.5.6 Compute Cluster + +A Compute Cluster is a selected set of Computer Systems that are physically interconnected through an Underlay Network and that can be used to setup a Node Cluster (as defined below). + +![Figure 3.4-4 Execution Environment Layer Concepts. The diagram illustrates the execution environment layers. The top layer, 'Compute Cluster', contains two 'Compute Nodes'. Each node consists of an 'OS Instance' (represented by a Linux logo) and 'Computer Systems' (represented by server icons). The bottom layer, 'Overlay Network', is connected to the 'Compute Cluster' and is linked to a 'Physical Underlay' network, which is represented by computer icons. Arrows indicate the flow of data and connectivity between these components.](fd4e75af754bdbc8893e8c4a03b0dd53_img.jpg) + +Figure 3.4-4 Execution Environment Layer Concepts. The diagram illustrates the execution environment layers. The top layer, 'Compute Cluster', contains two 'Compute Nodes'. Each node consists of an 'OS Instance' (represented by a Linux logo) and 'Computer Systems' (represented by server icons). The bottom layer, 'Overlay Network', is connected to the 'Compute Cluster' and is linked to a 'Physical Underlay' network, which is represented by computer icons. Arrows indicate the flow of data and connectivity between these components. + +Figure 3.4-4 Execution Environment Layer Concepts + +##### 3.4.3.5.7 Node Cluster + +A Node Cluster is a set of Overlay Network interconnected Compute Nodes of a specific type. The following are four types of Node Clusters. + +1. **Bare Metal Container Cluster** – A Bare Metal Container Cluster is a set of network-connected computer systems with their individual operating system instances that supports containers in a cluster configuration. +2. **VM-based Container Cluster** – A VM-based Container Cluster is a set of network-connected Virtual Machines with their individual guest operating system instance that supports containers in a clustered configuration. +3. **VM Cluster** – A VM Cluster is a set of network-connected Computer Systems with their individual operating instance that supports virtual machines in a cluster configuration. +4. **OS Cluster** – A OS Cluster is a set of network-connected Computer Systems with their individual operating system instance that supports a cluster configuration. + +## 3.5 O-Cloud Software Management + +Software Management should be a priority as without proper management unnecessary risks may be taken. Software Management ensures security, cost management and software support. There are many benefits to Software Management, of which the main benefits are: + +- Prevents unauthorized software from being installed +- Maintains a catalog of authorized software and its versions +- Provides visibility into what software and version is being used +- Provides a better view of which software products and versions are vendor supported + +In O-RAN from an O-Cloud perspective there are two types of software which needs to be managed on the O2 Interface: + +- The O-Cloud Infrastructure Software, it is described in the CADS [5] +- The O-RAN Cloudified Network Function Software is the software implementation of O-RAN NFs which is capable of running over the O-Cloud + +### 3.5.1 General Capabilities + +Pre-requisite: + +- O-RAN Cloudified Network Function Software Package is onboarded to SMO with required information, the details are FFS +- From an O-Cloud perspective the O-RAN Cloudified Network Function Software Image includes the underlying software executable image, image properties/metadata such as version +- Security/Certificates, the details are FFS + +Business Capabilities: + +- Network Operations shall be able to perform the Software Image Management of O-RAN Cloudified Network Function + +Functional Capabilities: + +- O-Cloud shall provide Add Software Images of O-RAN Cloudified Network Function to O-Cloud repository +- O-Cloud shall provide Delete Software Images of O-RAN Cloudified Network Function from O-Cloud repository +- O-Cloud shall provide Update Software Images of O-RAN Cloudified Network Function to O-Cloud repository +- O-Cloud shall provide Query Software Images of O-RAN Cloudified Network Function from O-Cloud repository +- O-Cloud shall provide Software Image properties information of O-RAN Cloudified Network Function. + - SoftwareImageId, Vendor, and Version + +### 3.5.2 O-Cloud Fault Management Concepts + +This section details general concepts related to IMS & DMS fault management. Fault management is a basic part of OA&M functions. The concepts described here will motivate the development of the O-Cloud O2 IMS & DMS Fault services and information modeling. + +The O-Cloud maybe a confederation of resource pools comprised of various compute, storage and networking resources. These might be provided by different public cloud providers. The public cloud provider is defined as computing services offered by third-party providers over the public Internet, making them available to anyone who wants to use or purchase them. Thus, it is important to outline some basic principles that can apply and are relevant to disparate vendors and providers. + +The following basic concepts are considered for IMS & DMS fault management: + +#### 3.5.2.1 Fault Information Model + +A fault information model is expected to be developed in the O2ims information model. As a general concept, an information model provides a common lexicon, terminology, and model to serve as a basis for coordination between a group of actors. It facilitates communications between groups and aligns their contributions. The fault information model is applicable for the resources & resource pools as defined in the infrastructure information model. + +#### 3.5.2.2 Subscription + +It is expected that there will be a subscription mechanism between a client and an agent. The client would pass an endpoint where notifications should be sent to. It is expected that multiple clients can be supported. Procedures are expected to be defined in the Fault O2 specifications for IMS and DMS. Subscriptions originate from the client (e.g. SMO). + +For example, the concept of a subscription allows a client, such as the SMO, to register for call-backs to the O-Cloud to receive fault notifications. + +#### 3.5.2.3 Notifications + +Fault notifications originate from the O-cloud infrastructure. There is a relationship between the subscription and notification. When a condition occurs within the IMS that warrants a fault notification an event is issued towards clients that have subscribed to receive such a type of notification or event. + +For example, a user could receive alerts on a fault dashboard GUI based on cloud IMS fault notifications. + +#### 3.5.2.4 Parallel Reporting + +A fault occurrence on an O-Cloud resource should be reported through IMS. DMS resource faults are associated with a workload. It is possible that multiple resources can associate with a workload, whereby one fault might trigger a fault notification on IMS, DMS and O1. Due to the nature of the subscribe/notify mechanism for fault reporting, it is possible to: (1) have multiple publishers sending to a single consumer and (2) conversely a single publisher that can send to multiple consumers. The interfaces for subscription & notification of fault reporting are: O2ims, O2dms, O1. + +For example, it is conceivable that a vDU application might report a fault on O1, and a related physical server allocated to a workload of a vDU would raise a DMS fault which might also have an infrastructure fault raised on IMS. + +#### 3.5.2.5 Simple Devices + +Collectively, in the O-Cloud it is conceivable that many devices are simple devices that do not have a full suite of OAM S/W. + +For example, suppose a network interface card (NIC) is a resource that is a simple device, and if that NIC encounters a fault it might not be able to register, store, or log faults. It is expected that O-Cloud infrastructure could manage these kinds of simple devices to be able to fulfill some of the other basic fault concepts described in this section. The O-Cloud infrastructure works with the IMS to report these faults. + +#### 3.5.2.6 Source of Truth + +In an O-Cloud IMS context, it is expected that the “*source of truth*” will be the resources of the O-Cloud itself. When a fault which has been reported to a client, such as the SMO, the fault data is replicated within the fault notification to provide details and information of the fault. Thus, the fault information now exists in multiple places both in the IMS and the entity receiving the fault notification. Which element then has the “true” information should the network or elements be disconnected or faulty? After connectivity returns, how would the SMO reconcile its view of the existing fault against the current faults on the O-Cloud resource? The answer is to query the *source of truth* (O-Cloud resource) for the most current faults. + +For example, if a resource in the O-Cloud goes out of service, and it had previously sent a fault notification, and then later returns to service, potentially the information at the client and the O-Cloud resource may have different fault information. But the O-Cloud resource is the source of truth and it is expected that client (IMS) would query the O-Cloud resource for the current information and reconcile that with client data. + +#### 3.5.2.7 Fault Dictionary + +A fault dictionary is a reference that can be provided by an O-Cloud vendor which details the faults that can be emitted from O-Cloud resources. The fault dictionary defines conditions that could be reported by the O-Cloud so that the SMO could act on those. The desirable goal is commonality of the fault dictionaries across O-Clouds even though they will differ to some degree by implementation. + +For example, the fault dictionary could be used for a variety of purposes. It might help a user decode the meaning of a fault notification. As another example, a fault dictionary could allow for fault signatures or patterns to be identified which may constitute a condition which requires a coordinated response. + +#### 3.5.2.8 Queries + +In the IMS case, the SMO (client) can issue a specific fault query towards to IMS (publisher) related to the O-Cloud resources and resource pool. In the SMO to DMS case, the SMO (client) can issue a specific query related to xApp/NF deployments (e.g. workloads) from the DMS (publisher). In the IMS case, a fault query is a message which is expecting a response message from the IMS which matches the selection criteria. In the DMS case, the fault query is expecting a response from the DMS. + +For example, the client may request status of a specific type of fault, or new active alarms conditions. The O-Cloud resource would reply to the query by responding with database on the parameters of the query (e.g. IDs or severity). + +#### 3.5.2.9 Filtering + +It is expected that the client, such as the SMO, can query for specific kinds of faults or groups of faults through a filter. In addition, filtering can also be applied to subscriptions to determine if notifications should be set. + +For example, it might request from the O-Cloud all the major severity alarms from a particular O-Cloud resource. The O-Cloud would select records based on the query pattern and send the details according to the notifications. This concept will guide the IMS information model development of procedures that can support filtering. + +#### 3.5.2.10 Fault Logging + +Fault logging may be part of the general event logging and is a concept where faults are stored at the O-Cloud resource (the *source of truth*) for a configured amount of time. IMS provisioning should be able to configure the amount of time that logs stored for. The concept of fault logging and storing faults allows a client, algorithm, or user to query for the fault log and analyze those faults. The faults should be timestamped with a common time format and clock source. Faults that are intermittent, repetitive, or transient can be identified this way. For example, Debug traces used by some O-cloud providers might be a way to facilitate fault logging meaning that certain condition can trigger writing to the fault log. + +For example, fault from an O-Cloud resource could be stored in a log for 1 week. + +#### 3.5.2.11 Alarm Synchronization + +There are many potential situations where a client and source of truth might become disconnected or disrupted. In this case, the client will need to synchronize with the source of truth after it is able to reconnect. + +For example, network fault might prevent communication between the SMO (client) and IMS resources in the O-Cloud. By the time connectivity has been restored, many new alarm conditions might have arisen and logged. This would motivate the SMO to resynchronize to get the current alarms again. A variety of mechanisms might be used to trigger alarm resynchronization. It might also trigger an upload of the most recent fault logs. + +#### 3.5.2.12 Alarm Correlation + +In Concept #4 with Parallel Reporting, it might be possible that a fault condition might result in a variety of different conditions or be reported in any combination of IMS, DMS and O1 fault notifications. It is not the job of the O-Cloud IMS fault management to correlate faults between the application/NF and O-Cloud resources. Thus, it would be up to higher layers of fault management to correlate disparate fault events to identify common root causes. + +For example, the SMO may receive a fault with a root cause of a network issue among the O-Cloud resources which manifests itself in a deployment and application fault as well. Thus, the SMO might receive three notifications over O2ims, O2dms and O1. It might correlate these faults to a common root cause. + +![Diagram illustrating Parallel Reporting & Alarm Correlation. The diagram shows a stack of layers: Management (SMO), Applications, DMS Workloads, and IMS Resources. The SMO layer contains FOCOM and NFO components. The Applications layer contains an Applications box. The DMS Workloads layer contains a Workloads box. The IMS Resources layer contains a row of server racks. Arrows indicate reporting paths: O2ims from IMS Resources to SMO, O2dms from Workloads to SMO, and O1 from Applications to SMO.](220f714d254aebd84a9b781f1ee77eb6_img.jpg) + +**PARALLEL REPORTING & ALARM CORRELATION** + +*Correlation occurs at the management layer (SMO) because it has a view of alarms coming from parallel reporting through O1, O2dms and O2ims pathways.* + +``` + +graph TD + subgraph Management + SMO[SMO] + SMO --- FOCOM[FOCOM] + SMO --- NFO[NFO] + end + subgraph Applications + Apps[Applications] + end + subgraph DMS_Workloads + Workloads[Workloads] + end + subgraph IMS_Resources + Servers[IMS Resources] + end + Apps -- O1 --> SMO + Workloads -- O2dms --> SMO + Servers -- O2ims --> SMO + +``` + +Diagram illustrating Parallel Reporting & Alarm Correlation. The diagram shows a stack of layers: Management (SMO), Applications, DMS Workloads, and IMS Resources. The SMO layer contains FOCOM and NFO components. The Applications layer contains an Applications box. The DMS Workloads layer contains a Workloads box. The IMS Resources layer contains a row of server racks. Arrows indicate reporting paths: O2ims from IMS Resources to SMO, O2dms from Workloads to SMO, and O1 from Applications to SMO. + +Figure 3.5-1 Parallel Reporting & Alarm Correlation + +#### 3.5.2.13 Escalation Strategy + +Fault conditions in an IMS resource may trigger an escalation strategy. An escalation strategy is a mechanism to increase visibility to a condition of duress which is typically a precursor to a more severe situation. + +For example, recurring alarms, fault signatures and severity levels may have an escalation strategy to raise higher severity alarms for higher tier recovery actions. As another example, a minor alarm in an O-Cloud resource with a certain occurrence rate within a time window might trigger an escalation strategy to raise a major alarm. + +#### 3.5.2.14 Fault Domains + +A fault domain is a “unit of failure”. A fault domain associates a collection of IMS O-Cloud resources together. We expect a fault domain to be within a Data Center Zone (see the provisioning chapter basic concepts for more detail). Faults could be associated with a fault domain. In the context of IMS fault area, fault domains are an attribute that could be correlative but do not have intrinsic fault operations, they are not a manageable entity. + +This would allow operators to design systems that are fault tolerant across fault domains. This might also guide placement strategies, and update cycles to improve reliability and availability. + +For example, a network cloud can host some number of servers per rack (e.g. 40 servers) with a number of racks of equipment (e.g. 10 racks) in a single deployment (totaling 400 servers). A fault domain might be defined to be rack. If a fault occurred, this concept would allow an operator trying to isolate the problem down to a rack (the fault domain). It would also allow a user to correlate a problem if multiple racks served by a common infrastructure resource. + +![Diagram illustrating the concept of Fault Domains. A large black box at the top is labeled 'FAULT DOMAIN'. Below it, a text box states 'A Fault Domain is a "unit of failure"'. The main diagram shows three horizontal rows of server racks. Each row is enclosed in a red rectangular border and labeled 'Fault Domain' in red text to the right. On the left, a green box labeled 'IMS Resources' has two arrows pointing to the first two rows. A smaller green box labeled 'Individual IMS Resource' has an arrow pointing to a single server rack within the first row.](6c5af5ac0c91a5b6dd8842fc048e8078_img.jpg) + +Diagram illustrating the concept of Fault Domains. A large black box at the top is labeled 'FAULT DOMAIN'. Below it, a text box states 'A Fault Domain is a "unit of failure"'. The main diagram shows three horizontal rows of server racks. Each row is enclosed in a red rectangular border and labeled 'Fault Domain' in red text to the right. On the left, a green box labeled 'IMS Resources' has two arrows pointing to the first two rows. A smaller green box labeled 'Individual IMS Resource' has an arrow pointing to a single server rack within the first row. + +Figure 3.5-2 Concept of Fault Domains + +#### 3.5.2.15 Fault Tolerance + +A fault tolerant system is one that is designed to withstand failures and continue to be able to provide service. Based on observations, some *actions* can be taken to insure reliability. Fault tolerant solutions & strategies will vary between O-Cloud providers and network function providers. + +An example of a fault tolerant strategy is the use of geo-redundancy and Data Center Zones. Geographically separating Data Center Zones allows service to continue should a physical natural disaster strike one data center. An *action* might be to migrate traffic from one zone to another. + +#### 3.5.2.16 Metrics + +Metrics allow users to define thresholds to monitor and manage IMS O-Cloud resources. From these metrics, a user/system could take action based on threshold crossings and/or chart the metrics over time. Also, to achieve fault tolerance, there could be a mechanism for alerting, monitoring & auditing as a health check. + +For example, in the basic fault concept of *Escalation Strategies*, we might need metrics of how **often** a fault occurs within a certain period of time. These *metrics* might be used as a threshold in an escalation strategy for better reliability. If the fault occurred 100 times in an hour action might be taken. + +### 3.5.3 O-Cloud Performance Basic Concepts + +The following section describes basic concepts for O2 Performance Concepts. + +In general, the purpose of performance is to report operational information related to O-cloud resources. Typically, performance information allows an operator or administrator of the O-cloud a sense of how well the system is operating. It is distinct from faults in that it is not about failures in the system but about how well the overall system is performing. Though, faults or alarms may negatively impact performance of the O-Cloud which might be observable in performance measurements. + +Performance measurements are typically captured periodically through time. They are collected and stored at regular intervals by the system in order to gauge the performance of a system over a period of time. This allows for analytical operations to be performed on the collected data and statistics to be built over time. This can tell an operator or system + +analyst whether they have sufficient capacity in a network based on the demands of the network. This can be vital for making business operational decisions such as scaling a network. + +The following are basic performance related concepts that will be used in the O2 Cloud performance use cases and modeling. + +![Figure 3.5-3 Performance Measurement Reporting diagram. The diagram shows a Service Management Orchestrator (SMO) at the top, receiving a 'Measurement Sent' message from the O-Cloud. The O-Cloud contains O-Cloud Resources, which generate 'Measurement Taken' data (represented by a gauge icon). This data is then processed into a 'Measurement Report' (represented by a document icon) and sent to the SMO.](c73d23b04412d51220757a916c7dde1a_img.jpg) + +``` + +graph TD + SMO[Service Management Orchestrator SMO] + subgraph OCloud [O-Cloud] + OR1[O-Cloud Resource] + OR2[O-Cloud Resource] + MT((Measurement Taken)) + MR((Measurement Report)) + end + OR1 --> MT + OR2 --> MT + MT --> MR + MR -- "Measurement Sent" --> SMO + +``` + +Figure 3.5-3 Performance Measurement Reporting diagram. The diagram shows a Service Management Orchestrator (SMO) at the top, receiving a 'Measurement Sent' message from the O-Cloud. The O-Cloud contains O-Cloud Resources, which generate 'Measurement Taken' data (represented by a gauge icon). This data is then processed into a 'Measurement Report' (represented by a document icon) and sent to the SMO. + +Figure 3.5-3 Performance Measurement Reporting + +#### 3.5.3.1 O-Cloud Performance Measurements + +Measurements are defined as the act of quantitatively checking the O-Cloud resources for defined gauges of operation. A measurement is an individual quantitative gauge of a quality. + +For example, the O-Cloud might measure the computational performance of an O-Cloud compute resource in terms of CPU utilization. + +#### 3.5.3.2 Performance Indicators + +Performance indicators take execution measurements and use them in a way that can give a meaningful notion of how a system is utilizing its resources and/or how well a system is operating. Indicators might be local in the sense of a function or more broader in scope for a group of functions. Performance indicators are typically a formula-driven application usage of performance measurements. Thus, the indicators are amenable to statistical analysis. The indicator formula needs to be exposed so that users can understand the meaning of the indicator. Indicators use a measurement, or gauge, to show an aspect of a thing. Key Performance Indicators (KPI) are performance indicators that are typically used to detect and report overall network health. + +For example, the CPU utilization might be a performance measurement. A performance indicator might be the fraction of time that a system is over a threshold, such as 80% CPU utilization. This would be a simple ratio calculation that could give a sense of how close to being overloaded a system is. + +#### 3.5.3.3 Performance Metric + +A performance metric represents standards of measurements. Metrics might be pre-defined, or they might define performance threshold targets to try to achieve. Metrics may utilize measurements and indicators. Performance metrics could be used by O-Cloud operators to achieve OPEX business objectives. + +For example, a performance metric could be a target that an operator would like to have a system operate at. For example, a metric to operate at five-9's reliability, or CPU utilization that is under a threshold. + +#### 3.5.3.4 Performance Reports + +Performance reports are a collection of measurements. Usually, they are gathered in a file; however, they may also be sent as a data stream. Typically, reports are created at regular (configurable) intervals or triggered by thresholds. The creation of performance reports may also be manually invoked. + +For example, The O-Cloud might compose a performance report which is comprised of several performance measurements recorded and stored at regular intervals. + +#### 3.5.3.5 Performance Management (PM) Job + +A performance management job is a task whose purpose is to collect measurements, creating a measurement file, and get a performance report according to criteria set by the user. The criteria could be used to specify measurements to collect. Note: 3GPP standards also discuss measurement jobs see references, 3GPP TS28.550, TS28.531. ETSI SOL003. + +For example, a PM job might be scheduled to run at 11 PM with the criteria to retrieve CPU measurements for O-Cloud resources and compose them into a measurement report. + +#### 3.5.3.6 Source of Truth + +The source of truth is the arbiter of discrepancies in metrics. In an O-Cloud IMS Performance context, it is expected that the "*source of truth*" will be the O-Cloud (IMS + O-Cloud infrastructure resources). The PM job manages the transformation of data into a performance report. The PM job requests data from the O-Cloud (the Source of Truth) to build the performance report. + +For example, suppose there is a metric from the source of truth with a reported value of 50, and the performance report has a value of 20. That value of 20 might have been a result of corruption in sending, composition, or a software bug. In order to obtain the proper value, the source of truth can be consulted. + +#### 3.5.3.7 Performance Threshold + +A performance threshold is a level or value which is used to check if a measurement exceeds or stays within. Typically, thresholds are used to trigger behavior or policies in a system. + +For example, a user might set a CPU utilization threshold of 80%. + +#### 3.5.3.8 Performance Dictionary + +A performance dictionary is a reference that is provided by a resource type vendor. A PM dictionary provides information on performance metrics or KPIs that are relevant to that resource type. The Performance (PM) Dictionary would be onboarded when a new resource type is added; and that resource type would come with an associated a PM dictionary. The PM dictionary for a resource type includes all measurements supported by the resource type including ones defined by standards and the reference to the standard. + +For example, there will likely be some standardized measurements. For a CPU, that might be CPU utilization measured in percentage. However, there could also be a vendor's CPU that might have additional features such as pinning or huge page functionality. The PM dictionary for a resource type it might have all measurements that it supports including standardized measurements. + +## 3.6 O-Cloud Life Cycle Management + +O-Clouds are a set of hardware and software components that provide cloud computing capabilities to execute O-RAN Cloudified Network Functions. These O-Clouds can be deployed centrally or at edge based on the deployment scenario and this typically involves cost and complexity. The goal of O-Cloud Life Cycle Management is to reduce this cost and complexity by orchestrating the deployment and management of the O-Clouds. + +In O-RAN the O-Cloud Life Cycle Management will provide the following capabilities: + +- Deploy +- Registration +- Scale + +The objective of Deployment is to provide automated provisioning of the O-Cloud Infrastructure. + +The objective of Registration is to register an O-Cloud and make it available for deployments. The SMO provides information for the registration of O-Clouds, this includes; security handshake required for the trusted connection, the O-Cloud IMS endpoint, and the O-Cloud ID which is used to correlate the SMO inventory record with the deployed cloud instance. + +After the registration of an O-Cloud with the SMO, the following information but not limited to can be discovered: + +- O-Cloud (IMS) provided Inventory services + - List of All Resource Pools in the O-Cloud + - Attributes of a specific O-Cloud + - List of all resources of an O-Cloud Pool + - Attributes of each O-Cloud Resource + - List of all DMS +- O-Cloud (DMS) provided Inventory services + - List of Locations Supported + - For a given location the Capabilities supported, such as: + - Descriptor types + - Technology types + - Accelerator types + - For a given location the Capacity of the location + - For a given location the Availability of the location + +The Scaling is FFS. + +## 3.7 O-Cloud Deployment Life Cycle Management + +RAN networks are in an evolutionary journey towards NFV/SDN, Openness and Network Function disaggregation. This journey enables the CSP's quest for future network and operational efficiency, where they can rapidly deliver new services and update the existing services with less cost than today. The goal is to reduce the time to market for a new service launch. + +To achieve this end state of higher service agility and lower operational economics, the CSPs are unambiguous in their support for a new network operational framework. The life cycle management of RAN network functions is an important consideration for this new network operational approach. + +In O-RAN, the O-Cloud will provide Deployment Life Cycle Management of O-RAN Cloudified Network Functions. The following capabilities will be provided: + +- Deploy, which deploys O-RAN Cloudified Network Functions on O-Cloud with necessary O-Cloud resources. +- Terminate, which terminates O-RAN Cloudified Network Functions on O-Cloud with releasing associated O-Cloud resources. +- Scale, which scales functional behavior and resources of O-RAN Cloudified Network Functions to support services. There is different variance in scaling: + +- Horizontal Scaling provides dynamic functional scaling of O-RAN Cloudified Network Functions' behavior by Scale in/Out. This scaling can have different invoke actors such as O-Cloud and SMO. +- Vertical Scaling provides dynamic resource scaling of O-RAN Cloudified Network Functions by Scale Up/Down. The details are FFS. +- Heal, which provides the ability to recover/mitigate the O-RAN Cloudified Network Functions' abnormal behaviour in the network. The details are FFS. +- Health Check. The details are FFS. +- Diagnostic. The details are FFS. + +![Figure 3.7-1 O2 Deployment LCM Services diagram. The diagram shows the interaction between Service Provider Functionality (SMO) and Cloud Provider Functionality (O-Cloud). The SMO layer includes Federated O-Cloud Orchestration and Management (FOCOM), Network Function Orchestrator (NFO), and OAM Function. The O-Cloud layer includes Infrastructure Management Services (IMS) and Deployment Management Services (DMS). A dashed line separates the two layers, labeled 'Separation of Concerns boundary'. Arrows indicate the flow of O2 and O2dms services. A legend on the right lists the capabilities: Deploy, Terminate, Scale, Heal, Health Check, and Diagnostic.](473b24ed2fd603ada0a3005f79b2cc89_img.jpg) + +Figure 3.7-1 O2 Deployment LCM Services diagram. The diagram shows the interaction between Service Provider Functionality (SMO) and Cloud Provider Functionality (O-Cloud). The SMO layer includes Federated O-Cloud Orchestration and Management (FOCOM), Network Function Orchestrator (NFO), and OAM Function. The O-Cloud layer includes Infrastructure Management Services (IMS) and Deployment Management Services (DMS). A dashed line separates the two layers, labeled 'Separation of Concerns boundary'. Arrows indicate the flow of O2 and O2dms services. A legend on the right lists the capabilities: Deploy, Terminate, Scale, Heal, Health Check, and Diagnostic. + +Figure 3.7-1 O2 Deployment LCM Services + +### 3.7.1 General Capabilities + +#### Business Capabilities: + +- The SMO provides the capability for Network Operations to initiate the lifecycle management functional capabilities + +#### Functional Capabilities: + +1. O-Cloud supports Deploying an O-RAN O-RAN Cloudified NF instance +2. O-Cloud supports Terminating an O-RAN Cloudified NF instance +3. O-Cloud supports Horizontal Scaling (in and out) of an O-RAN Cloudified NF instance +4. O-Cloud supports Healing of an O-RAN Cloudified Network Function instance, this is FFS. +5. O-Cloud supports Querying information about an O-RAN Cloudified NF instance +6. O-Cloud supports Querying status of LCM operations +7. O-Cloud supports Upgrading of any or all components of an O-RAN Cloudified NF instance + +### 3.7.2 Deployment Management Services + +The O-Cloud provides services over the O2dms interface to allow an SMO to trigger the functional capabilities specified in Section 3.7.1. As allowed by the O-RAN Cloud Architecture and Deployment Scenarios [12] specification, O-Cloud implementations can incorporate a multitude of virtualization technologies (e.g., VMs, containers, bare metal) and technology stacks which have major differences from each other. To account for these differences, each O-Cloud might have its own specific O2dms service API profile(s). An O2 DMS specification for a specific profile describes the API provided by the profile and how to use them to achieve the capabilities listed in Section 3.7.1. An SMO is intended to be able know which profile it is using and orchestrate according to description provided in the O2dms service API profile(s). The profile specific APIs will be defined in each stage 3 O2dms specification. + +The O2dms specification will contain the following information: + +- a) O-Cloud profile scope and technology stack: specifies what types of technologies (e.g., VMs, containers) the profile applies to and specifies particular software systems (e.g., K8S, Prometheus, etc.) and versions that are part of the stack +- b) O2dms functional capabilities description: specifies how the APIs provided by the O-Cloud Profile are used (e.g. interaction flow) to implement the functional capabilities specified in Section 3.7.1. To achieve these capabilities, dependent on the specific profile the SMO can do one or more of the following: + 1. Initiate the procedure via a single DMS API profile call. + 2. Orchestrate using several DMS API profile calls. + 3. Relegate responsibility to the O-Cloud by leveraging O-Cloud capabilities, SMO does nothing to manage these capabilities. +- c) O-Cloud profile API specification: specifies what APIs are provided by an O-Cloud conforming to the O-Cloud Profile +- d) O-Cloud profile data model: specifies the actual data elements used by the API. + +The O-Cloud Profiles form the basis for the protocol and data model O2dms interoperability – any O-Cloud implementation which supports a particular O-Cloud Profile is expected to interoperate with any SMO implementation that also supports the same O-Cloud Profile but not with an SMO that only supports a different O-Cloud Profile. + +# Annex A (Informative): O-Cloud and IMS Initialization + +This specification does not dictate how O-Cloud is initialized and how initial endpoint for SMO to connect to is done. But here are some logical steps of the process to make it happen. This is included for informational purposes and not part of formal specification, please see Orchestration Use Cases [13]. + +1. SMO manually populated with a server that will be part of HW that is in O-Cloud. That server has connectivity to all other HW in the O-Cloud currently (at the start). The choice of that initial server is not important and is used only for bootstrapping (Genesis). +2. SMO deploys a minimalistic IMS functionality to initial server so it can do a subset of IMS functionality and bring O-Cloud up. At a minimum that IMS services should include infrastructure discovery, inventory, and administration within the O-Cloud; and deployment of O-Cloud with full IMS and DMS functionality. The configuration of the network might be sent to the server as part of its startup. In which case it might not have connectivity to all other HW but will have the ability to establish connectivity by configuring a transport path to servers in a non-collocated resource pool. +3. After O-Cloud deployment the initial server is no longer needed for minimalistic IMS services and can be returned into a pool of resources under O-Cloud control. The registration of the complete IMS services endpoint in the SMO, via a callback provided to the initial server, exposes the internal cloud services to the SMO via the IMS SBI. + +This document does not define how O-Cloud with IMS services come into being. So, the above steps are provided for informational purposes only. + +## UML sequence diagram for O-Cloud and IMS initialization + +``` +@startuml +Autonumber +skinparam sequenceArrowThickness 2 +skinparam ParticipantPadding 5 +skinparam BoxPadding 10 + +Box "Personnel" #lightblue +Actor CPM as "Site Administrator" +End box + +Box "Service Management & Orchestration Framework" #gold +participant SMO as "FOCOM" +``` + +``` + +end box +Box "O-Cloud Platform" #lightseagreen + participant IMS as "O-Cloud Genesis Server" +End box + + CPM -> SMO: Instantiate O-Cloud IMS + +SMO -> IMS: Setup Server +Note over IMS + Install Operating System and any necessary SW +End note + + IMS -> SMO: initial Server Ready + +SMO -> IMS: Install Basic IMS +Note over IMS + Install initial IMS +End note + + IMS -> SMO: IMS Cloud Infrastructure Resource Management services is ready + +SMO -> CPM: Initial O-Cloud is Ready +== End Use Case == +@enduml + +``` + +![Sequence diagram showing O-Cloud and IMS Initialization. The diagram involves three main lifelines: Personnel (Site Administrator), Service Management & Orchestration Framework (FOCOM), and O-Cloud Platform (O-Cloud Genesis Server). The process starts with the Site Administrator sending a message '1 Instantiate O-Cloud IMS' to FOCOM. FOCOM then sends '2 Setup Server' to the O-Cloud Genesis Server. The O-Cloud Genesis Server performs an internal action 'Install Operating System and any necessary SW' and then sends '3 initial Server Ready' back to FOCOM. FOCOM sends '4 Install Basic IMS' to the O-Cloud Genesis Server, which performs an internal action 'Install initial IMS'. The O-Cloud Genesis Server then sends '5 IMS Cloud Infrastructure Resource Management services is ready' back to FOCOM. Finally, FOCOM sends '6 Initial O-Cloud is Ready' back to the Site Administrator. The diagram is divided into two sections by a horizontal line labeled 'End Use Case'.](14b518dc833a52da02b498efb2213305_img.jpg) + +Sequence diagram showing O-Cloud and IMS Initialization. The diagram involves three main lifelines: Personnel (Site Administrator), Service Management & Orchestration Framework (FOCOM), and O-Cloud Platform (O-Cloud Genesis Server). The process starts with the Site Administrator sending a message '1 Instantiate O-Cloud IMS' to FOCOM. FOCOM then sends '2 Setup Server' to the O-Cloud Genesis Server. The O-Cloud Genesis Server performs an internal action 'Install Operating System and any necessary SW' and then sends '3 initial Server Ready' back to FOCOM. FOCOM sends '4 Install Basic IMS' to the O-Cloud Genesis Server, which performs an internal action 'Install initial IMS'. The O-Cloud Genesis Server then sends '5 IMS Cloud Infrastructure Resource Management services is ready' back to FOCOM. Finally, FOCOM sends '6 Initial O-Cloud is Ready' back to the Site Administrator. The diagram is divided into two sections by a horizontal line labeled 'End Use Case'. + +Figure A-1 O-Cloud and IMS Initialization + +# Annex ZZZ O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +### Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an ORAN Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +### Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter’s distributors and the use by the Adopter’s customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter + +is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +### Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of ORAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +### Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +### Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +### Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, + +IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. + +O-RAN SPECIFICATIONS ARE PROVIDED “AS IS” WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +### Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance’s sole discretion. O-RAN Alliance may freely assign this Agreement. + +### Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +### Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity’s or association’s agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +### Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates’ performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. + +Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties’ or third party beneficiary’s right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full force and effect. + +1 + +2 \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/raw.md b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..aa08d07c7b07fe12a1afd8b7da4767b2a88d211a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00/raw.md @@ -0,0 +1,404 @@ + + +# --- O-RAN Work Group 6 + +# O2 IMS K8s Technical Report + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this document in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this document for your personal use, or copy the material of this document for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +# --- Contents + +| | | +|--------------------------------------------------------|----| +| Foreword ..... | 3 | +| Modal verbs terminology ..... | 3 | +| 1 Scope..... | 4 | +| 2 References..... | 4 | +| 2.1 Informative references..... | 4 | +| 3 Definition of terms, symbols and abbreviations ..... | 5 | +| 3.1 Terms..... | 5 | +| 3.2 Symbols..... | 5 | +| 3.3 Abbreviations ..... | 5 | +| 4 Study of O2-IMS K8s interface ..... | 5 | +| 4.1 Context ..... | 5 | +| 4.2 Objectives..... | 5 | +| 4.3 Declarative K8s API approach..... | 6 | +| 4.3.1 Kubernetes Object Management techniques ..... | 6 | +| 4.3.2 Declarative object management benefits..... | 6 | +| 4.3.3 Industry Adoption..... | 7 | +| 4.4 O2-IMS Services Analysis..... | 7 | +| 4.4.1 Introduction ..... | 7 | +| 4.4.2 Inventory Service..... | 7 | +| 4.4.3 Provisioning Service..... | 8 | +| 4.4.4 Lifecycle Management Service ..... | 9 | +| 4.4.5 Software Management Services ..... | 9 | +| 4.4.6 Monitoring Service ..... | 9 | +| 4.5 Proposal for O2-IMS K8s interface support ..... | 10 | +| 4.5.1 Introduction ..... | 10 | +| 4.5.2 URI compatibility ..... | 10 | +| 4.5.3 Example of K8s API for Cluster Template ..... | 11 | +| 4.5.4 Proposal ..... | 11 | +| 4.6 Impact on WG6 Specifications and Use Cases ..... | 12 | +| History ..... | 12 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +--- + +## Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document specifies a study of the applicability of a K8s declarative interface for O-RAN O2 IMS interface. + +# --- 2 References + +## 2.1 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +[1] Kubernetes® API, online <https://kubernetes.io/docs/reference/kubernetes-api/> + +[2] Kubernetes® Object Management, online: <https://kubernetes.io/docs/concepts/overview/working-with-objects/object-management/> + +[3] Kubernetes® CLI book, online: <https://kubectl.docs.kubernetes.io/> + +[4] The Cloud-Native Telco Market Perception Report, Telecom TV, online: <https://www.telecomtv.com/content/cloud-native-telco-report-sep-23/> + +[5] Cloud Native Definition, v1.0, online: <https://github.com/cncf/toc/blob/main/DEFINITION.md> + +[6] GitOps Definition, online: <https://opengitops.dev/> + +[7] Kubernetes Resource URIs, online, <https://kubernetes.io/docs/reference/using-api/api-concepts/#resource-uris> + +- [8] Kubernetes CRD Validation Rules, online, <https://kubernetes.io/docs/tasks/extend-kubernetes/custom-resources/custom-resource-definitions/#validation-rules> +- [9] O-RAN-WG6.O2IMS-INTERFACE: “O2ims Interface Specification” +- [10] Helm, online, <https://helm.sh/> +- [11] Git, online, <https://git-scm.com/> +- [12] Kustomize, online, <https://kustomize.io/> + +NOTE: Kubernetes® and K8s® are registered trademarks of the Linux Foundation, in the United States and other countries. O-RAN is not affiliated with, endorsed, or sponsored by the Linux Foundation. + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +**GitOps:** Set of practices to manage infrastructure and application configurations using Git as a single source of truth ensuring the operational state of systems is consistent with the intended state. + +NOTE: This is defined by the CNCF GitOps Working Group [6] + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +## 3.3 Abbreviations + +For the purposes of the present document, the [following] abbreviations [given in ... and the following] apply: + +# --- 4 Study of O2-IMS K8s interface + +## 4.1 Context + +The background for this study arises from the increasing adoption of cloud-native network functions and their impact on infrastructure management systems. Cloud-native principles advocate for declarative-based management for network functions, wherein the desired end state is described, rather than specifying the sequence of steps to achieve that state. The shift towards declarative models has not been fully explored for infrastructure management services within the context of the O2 interface. + +As of specification v04.00, O2-IMS interfaces follow an imperative model approach for infrastructure management. This approach does not enable direct cloud native integration with Kubernetes which is a prominent container orchestrator widely used in the industry. + +The study's findings are expected to provide insights into the feasibility and benefits of adopting a declarative K8s API approach for the O2-IMS interface. This analysis will assist WG6 in making informed choices regarding the evolution of O2-IMS ecosystem. By understanding the impact and potential modifications, the study aims to accelerate the adoption of O2-IMS and leverage industry best practices. + +## 4.2 Objectives + +The main objective of the present Technical Report is to conduct a comprehensive analysis of the O2-IMS interface with a focus on exploring the feasibility, drawback and benefits of adopting a declarative K8s API approach. + +To achieve this goal, the study is structured around the following specific objects: + +- Declarative K8s API approach +- O2-IMS services analysis +- Proposal for O2-IMS K8s interface support +- Impact on WG6 Specifications and Use Cases + +## 4.3 Declarative K8s API approach + +### 4.3.1 Kubernetes Object Management techniques + +As defined in the Kubernetes Object Management [2] documentation, three management techniques exist: + +- Imperative commands + - “A user operates directly on live objects in a cluster. The user provides operations to the kubectl command as arguments or flags.” + - “This is the recommended way to run a one-off task in a cluster; it operates directly on live objects and provides no history of previous configurations.” +- Imperative object configuration + - “The kubectl command specifies the operation (create, replace, etc.), optional flags, and at least one file name. The file specified contains a full definition of the object in YAML or JSON format.” +- Declarative object configuration + - “A user operates on object configuration files stored locally; however, the user does not define the operations to be taken on the files. Create, update, and delete operations are automatically detected per object by kubectl. This enables working on directories, where different operations might be needed for different objects.” + +The Kubernetes documentation exemplifies and defines advantage and disadvantage for each of these techniques. + +### 4.3.2 Declarative object management benefits + +Declarative Kubernetes (K8s) API is one of the fundamental concepts that Kubernetes is built upon. As depicted in the previous section, it refers to the practice of defining the desired state of applications in a declarative manner, rather than imperatively specifying the steps to achieve that state. There are several benefits to using a declarative approach with the Kubernetes API: + +- **Desired State Management:** Declarative APIs enable specifying what the system is expected to look like (the desired state) rather than how to get there (the imperative steps). Kubernetes controllers continuously work to reconcile the current state with the desired state, automatically making adjustments as needed. This simplifies operations of keeping resources in sync with the intention and reduces the risk of configuration drift. +- **Resilient:** Declarative object configuration enables Kubernetes to automatically detect and recover from failures. If a pod or other resource goes down or becomes unhealthy, Kubernetes will automatically create a new instance to maintain the desired state. +- **Idempotence:** In a declarative API, applying the same configuration multiple times have the same result as applying it once. This idempotence property reduces the risk of unexpected changes or side effects when managing resources. +- **Scalability:** Objects created declaratively are often easier to scale because multiple instances of the same resource using the same configuration template can be defined. Kubernetes can then create and manage these instances as needed. +- **Version Control and Auditing:** Declarative configurations can be stored in version control systems like Git [11], allowing for versioning, history tracking, and easy collaboration. This helps with auditing and troubleshooting as the evolution of the configuration is visible over time. +- **Predictable Rollouts and Rollbacks:** With declarative APIs, a new desired state can be specified, and Kubernetes will manage the rollout and rollback of resources to achieve that state. This makes it easier to perform updates and handle failures gracefully. +- **Portability:** Declarative configurations are often agnostic to the underlying infrastructure, making it easier to move workloads between different Kubernetes clusters or cloud providers. If the declarative configurations embed some details that are specific to some environments, then the portability becomes limited to these environments. +- **Automation and Tooling:** Declarative APIs are well-suited for automation because configuration is defined as code enabling the use of tools like Helm [10], Kustomize [12], or operators to manage complex applications and resources. +- **Human-Readable:** Declarative configurations are often more human-readable and maintainable compared to imperative scripts or instructions, which can be error-prone and hard to understand. + +In summary, the declarative nature of the Kubernetes API simplifies resource management, enhances automation, increase reliability, and makes it easier to work with complex infrastructure and applications in a dynamic environment like Kubernetes. + +NOTE: The present document only assesses Kubernetes technology; it can be possible to realize these benefits with other technologies as well. + +### 4.3.3 Industry Adoption + +As highlighted in the CNCF Cloud Native Definition v1.0 [5], the adoption of declarative APIs empowers organizations to develop and operate scalable applications in modern and dynamic environments, introducing GitOps as a new approach for managing the operation and the lifecycle of telecom networks. But transitioning to GitOps can be challenging due to potential cultural shifts and skillset gaps. + +At its core, GitOps principles encompass the following [6]: + +- **Declarative:** A system managed using GitOps expresses its desired state in a declarative manner. +- **Versioned and Immutable:** The desired state of a system is stored in a manner that enforces immutability, versioning, and maintains a complete version history. +- **Automatically Pulled:** Software agents automatically retrieve the desired state declarations from the source. +- **Continuously Reconciled:** Software agents consistently monitor the actual system state and strive to apply the desired state. + +The Cloud-Native Telco Market Perception Report [4] stipulates wanting “to know which technologies and companies are perceived by the network operator community to be important to cloud-native telco strategies – so [their report] is all about perception, not which technologies and companies are actually involved with, or linked to, any cloud-native developments at the network operators represented by our survey respondents.”. It reports 89% of respondents have adopted a cloud-native strategy, among which 90% reports Kubernetes as being important to meeting strategic goals (based on 38 responses from 21 companies). + +## 4.4 O2-IMS Services Analysis + +### 4.4.1 Introduction + +As of specification **v04.00**, the O2-IMS interface is composed of services at various stages of standardization. This section analyses each O2 IMS service, along with its applicability to a declarative interface. + +### 4.4.2 Inventory Service + +This service enables querying the O-Cloud resources and management services. + +The inventory service defines objects which are exposed as read-only to the SMO. The only REST resource method supported is “GET”, except for the Subscription object which also supports “POST” and “DELETE”. + +As part of the “GET” resource methods, a comprehensive list of query parameters is defined. + +It is technically possible to implement an inventory system with the O2 IMS Inventory objects defined as Kubernetes Custom Resource Definitions (CRDs), but there are certain considerations and challenges that can make this approach less desirable: + +- **Scalability and Performance:** CRDs can introduce performance overhead, especially when dealing with a large number of objects. Kubernetes itself is primarily designed for managing infrastructure and application workloads, and using it for inventory management might not be as efficient as purpose-built inventory systems. +- **Complexity:** Managing inventory typically involves complex data structures and relationships. CRDs might not provide the necessary data modeling and querying capabilities needed for complex + +inventory structures, which could lead to a more complex and less efficient inventory management system. + +- **Lack of Inventory-Specific Features:** Kubernetes CRDs are not designed specifically for inventory management. They lack features such as built-in reporting, auditing, and advanced querying capabilities that are often essential for inventory systems. +- **Data Consistency:** Ensuring data consistency and integrity in an inventory system is critical. CRDs do not inherently enforce data consistency rules or provide transactional guarantees, which might be necessary for inventory systems with stringent data requirements. +- **Limited Control over Data Storage:** Kubernetes abstracts much of the underlying infrastructure, including data storage. In some cases, it can be needed to have more control over how inventory data is stored, indexed, and retrieved than what CRDs offer. +- **Migration and Portability:** It can be challenging to extract and convert data from Kubernetes CRDs when the inventory system needs to migrate to a different platform or infrastructure. + +Kubernetes CRDs provide flexibility and extensibility for managing custom resources within a Kubernetes cluster, they might not be the best choice for implementing a complex inventory management system. It can be more practical to use purpose-built inventory management tools or databases that are designed to handle the complexities and challenges associated with inventory management. + +### 4.4.3 Provisioning Service + +This service support procedures for the automation of O-Cloud cluster lifecycle events, such as O-Cloud cluster creation, deletion or scaling. It is currently undefined, but actively discussed. + +Provisioning clusters declaratively through CRDs can offer several advantages, especially in scenarios where a high degree of automation, customization, and control over cluster deployments is expected. Some of the advantages are: + +- **Infrastructure as Code (IaC):** Declarative provisioning with CRDs enables defining the cluster lifecycle management operations as code. This means the cluster configuration can be versioned, reviewed, and managed using familiar development practices, making it easier to track changes and collaborate with others. +- **Automation:** CRDs enable automation of cluster provisioning. By defining the cluster's desired state in CRDs, tools like Kubernetes Operators or custom controllers can be used to automatically reconcile the actual state with the desired state, reducing manual intervention and potential human error. +- **Customization:** Kubernetes CRDs enable customization of the cluster's configuration to the specific needs. Custom resource types to represent different types of clusters (e.g., development, production, testing) and configure them with distinct settings, such as node sizes, networking options, and addons, can be defined. +- **Reusability:** CRD definitions can be reused and shared across different infrastructures or environments. This can lead to consistent cluster configurations and simplify the management of multiple clusters with similar requirements. +- **Versioning and Rollbacks:** CRD-based configurations are versioned, making it straightforward to roll back to previous cluster configurations if issues arise during an update. This provides a safety net for changes to the cluster infrastructure. + +- **Ecosystem Integration:** Using CRDs aligns the cluster provisioning process with Kubernetes-native concepts, making it easier to integrate with other Kubernetes components and tools in the ecosystem. This includes monitoring, logging, and scaling solutions designed to work seamlessly with Kubernetes. +- **Scalability:** As the needs change, scaling clusters up or down is achieved by updating the CRD instance configurations. This flexibility ensures the clusters can adapt to evolving workloads and resource requirements. +- **Continuous Integration/Continuous Deployment (CI/CD):** Declarative cluster provisioning fits seamlessly into CI/CD pipelines by automating cluster creation as part of the deployment process, ensuring clusters are always up to date with the latest configurations. + +Declarative provisioning of clusters through CRDs offers a powerful way to automate, customize, and manage clusters efficiently. It aligns well with Kubernetes principles and best practices, making it a compelling choice for organizations seeking greater control and automation over their cluster infrastructure. + +The concept of Cluster Template aims at capturing O-Cloud Node Cluster configurations for an O-Cloud. It is inline with the goal of the present document of adopting a declarative API approach for the provisioning service. And this is inline with the goal of having a declarative way to manage lifecycle events of O-Cloud Node Clusters. + +**NOTE:** As of issuing the present document version, the cluster template concept is being still developed. Depending on the standardization of cluster templates (such as models, associated interfaces, etc.), the descriptions above can be revisited. + +### 4.4.4 Lifecycle Management Service + +This service supports procedures for the automation of O-Clouds lifecycle events, such as O-Cloud Genesis and O-Cloud Scaling. It is currently not defined. + +As it stands, no analysis can be made for the first version of the present Technical Report. + +### 4.4.5 Software Management Services + +This service supports procedures that enable SMO/FOCOM to initiate the software update process for the O-Cloud Infrastructure Management software, the Deployment Management software, Server OS Software, updates, and patches, and firmware updates for accelerators. It is currently not defined. + +As it stands, no analysis can be made for the first version of the present Technical Report. + +### 4.4.6 Monitoring Service + +This service supports procedures that enable a consumer i.e., SMO, to monitor the reachability of the IMS, as well as subscribe to alarms, faults and performance metrics that can be generated by Infrastructure Inventory objects. The information model and some service operations are defined. + +Kubernetes CRDs offer a flexible way to extend the Kubernetes API and define custom resources, but they might not be the most suitable choice for implementing a monitoring service for metrics, faults, and alarms for the following reasons: + +- **Performance Overhead:** Monitoring systems typically deal with high volumes of data and require low-latency access to metrics and alarms. Storing this data as CRDs within Kubernetes can introduce performance overhead due to the way Kubernetes handles resource storage and retrieval. +- **Data Volume and Retention:** Monitoring systems often generate and store a large amount of time-series data. Storing this data as CRDs could lead to scalability issues and challenges related to data retention and purging, which are better addressed by specialized data stores designed for time-series data. +- **Data Querying and Aggregation:** Monitoring systems require powerful querying and aggregation capabilities to extract meaningful insights from metrics and alarms. CRDs cannot provide the necessary querying features, and querying CRDs directly could be inefficient and cumbersome. +- **Data Transformation and Enrichment:** Monitoring often involves data transformation and enrichment processes to make sense of raw metrics and create meaningful dashboards and reports. Implementing these processes within CRDs can be complex and might not be the most efficient approach. +- **Scalability and High Availability:** Monitoring services scale horizontally to handle increasing data volumes and ensure high availability. Kubernetes CRDs might not offer the same level of scalability and high availability features as dedicated monitoring solutions. +- **Ecosystem Compatibility:** The broader monitoring ecosystem, including popular tools like Prometheus, Grafana, and Elasticsearch, is not natively designed to work with Kubernetes CRDs. Using CRDs needs of significant customization and integration work. +- **Operational Overhead:** Maintaining a monitoring system implemented with CRDs might introduce operational complexity, due to the management and maintenance both the monitoring system and the Kubernetes cluster. + +As described, CRDs might not be the best choice for implementing a comprehensive monitoring service. Specialized monitoring solutions are better equipped to handle the complexities of monitoring, alerting, data storage, querying, and integration with external systems and data sources, while also providing the necessary performance and scalability required for monitoring large-scale and critical applications. + +## 4.5 Proposal for O2-IMS K8s interface support + +### 4.5.1 Introduction + +Even though the benefits of a declarative interface are tangible, considering the analysis done in the previous section, they cannot be realized for the Monitoring and Inventory O2 IMS services: the O2 IMS Provisioning service is a good fit for having a declarative K8s interface. Regarding Software and Lifecycle Management, they will have to be re-assessed once fully defined or their specification progresses. + +The recommendation is to have an O2 IMS Provisioning data model in the format of a CRD for the following use-cases defined in the O-RAN-WG6.ORCH-USE-CASES-R003-v08.00 specification: + +- 3.11.2 Create Kubernetes (K8s) Cluster Use Case +- 3.11.3 Delete Kubernetes (K8s) Cluster Use Case +- 3.11.4 Update O-Cloud Node Cluster Use Case + +To avoid having two different interfaces for O2 IMS, the same information model could be used to define the RESTful API(s) and the CRD(s). + +NOTE: This recommendation introduces a fragmentation of the O2 IMS Interface for the O2 IMS Provisioning service. + +### 4.5.2 URI compatibility + +In Kubernetes, CRDs are accessed and managed through the Kubernetes API server, which listens on the following URI endpoint: `/apis/{group}/{version}/{resource}`. More details on Kubernetes Resource URIs can be found in its documentation [7]. + +An URI endpoint is comprised of the following parts: + +- **{group}**: The API group to which the CRD belongs. Custom resources are often grouped under a specific API group to avoid naming conflicts with built-in resources. For example, the group of a CRD for a custom application can be `myapp.example.com`. +- **{version}**: The version of the CRD. As the CRD evolves, there can create multiple versions to handle changes in the resource definition. For example, version can be `v1alpha1`, `v1beta1`, or `v1`. +- **{resource}**: The name of the custom resource. This is typically pluralized. For example, if the custom resource is called `MyApp`, the resource name might be `myapps`. + +The K8s URI endpoint structure is inline with the currently defined O2 IMS URI structure, defined in section 3.1.2 in v04.00: `{apiRoot}/<apiName>/<apiMajorVersion>/<apiSpecificResourceUriPart>` + +### 4.5.3 Example of K8s API for Cluster Template + +The following is an example CRD for the Cluster Template. It is very simple and only consists of two parameters: name and description. + +``` +apiVersion: apiextensions.k8s.io/v1 +kind: CustomResourceDefinition +metadata: + # name match the spec fields below, and be in the form: <plural>.<group> + name: clustertemplates.o2ims-infrastructureprovisioning.oran.alliance.org +spec: + # group name to use for REST API: /apis/<group>/<version> + group: o2ims-infrastructureprovisioning.oran.alliance.org + # list of versions supported by this CustomResourceDefinition + versions: + - name: v1 + # Each version can be enabled/disabled by Served flag. + served: true + storage: true + schema: + openAPIV3Schema: + description: 'ClusterTemplate is the schema for O2 IMS Provisioning' + type: object + properties: + spec: + description: 'Information representing an Cluster Template' + type: object + properties: + name: + description: Human readable name of the Cluster Template + type: string +``` + +``` + +description: + description: Human readable description of the Cluster Template + type: string +# either Namespaced or Cluster +scope: Cluster +names: + # plural name to be used in the URL: /apis/<group>/<version>/<plural> + plural: clustertemplates + # singular name to be used as an alias on the CLI and for display + singular: clustertemplate + # kind is normally the CamelCased singular type. Your resource manifests use this. + kind: ClusterTemplate + # shortNames allow shorter string to match your resource on the CLI + shortNames: + - ct + +``` + +In order to use this ClusterTemplate CRD declaratively, one can use the following Custom Resource + +``` + +apiVersion: O2ims-infrastructureprovisioning.oran.alliance.org/v1 +kind: ClusterTemplate +metadata: + name: example +spec: + name: "O-Cloud Node Cluster Template" + description: "Cluster Template for XYZ" + +``` + +In order to use this ClusterTemplate CRD through the Kubernetes API Server, one can use the following RESTful URI + +``` +/apis/O2ims-infrastructureprovisioning.oran.alliance.org/v1/clustertemplates +``` + +Finally, Kubernetes enable the extraction of OpenAPIv3 specification for the CRD using the following RESTful URI + +``` +/openapi/v3/apis/O2ims-infrastructureprovisioning.oran.alliance.org/v1 +``` + +### 4.5.4 Proposal + +In order to support both a RESTful interface and Kubernetes API for the O2 IMS Provisioning service, the proposal is: + +- Ensure the {apiName} comply to a lowercase RFC 1123 subdomain, section 2.1 "Host Names and Numbers" which limits host names to letters-digits-hyphen. +Example: O2ims-infrastructureprovisioning.oran-alliance.org +- Have one common information model. +- Have two data models; one being a JSON document, and one being in the format of CRD(s). + +By adopting this proposal, the O-Cloud O2 IMS interface implementation can support both the RESTful API and the Kubernetes CRD(s) as it enables the utilization of the CRD(s) through the RESTful interface created by Kubernetes, as illustrated in section 2.5.1. + +Communication between FOCOM and IMS via the O2 Interface, whether employing a RESTful API like the one specified for the O2 IMS Inventory Service or using CRD(s) as proposed in this section for the O2 IMS Provisioning Service, necessitates a single set of credentials for the consumer, i.e., FOCOM. This ensures a consistent authentication process for executing requests. + +As part of the data modeling in the format of CRD(s), it is expected that validation rules are also specified to ensure no unwanted functionality gets into the O-Cloud. Kubernetes has a well-defined mechanism to perform this validation [8]. + +NOTE: Depending on the level of completeness of the validation rules of CRD(s) within the O2 IMS Provisioning data model, the O-Cloud vendor could add additional validation rules for enhanced security. + +## 4.6 Impact on WG6 Specifications and Use Cases + +Further specification of the O2 IMS interface [9] might leverage the recommendations described in the present document. + +# --- History + +| Date | Revision | Description | +|------------|----------|----------------------------------| +| 2023.11.16 | 00.00.03 | Published as Final version 01.00 | \ No newline at end of file diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/05b4bb77477b40c58cc1fe4078f485af_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/05b4bb77477b40c58cc1fe4078f485af_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0290388e38cbbda938b402f7bc111129656e4397 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/05b4bb77477b40c58cc1fe4078f485af_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ccedcbd6f42f5ee6bf2536bd2de577cd89d8c44f7d70f251a809188e7a31896f +size 52826 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/1093a67aa29aa52066629da9d900e96c_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/1093a67aa29aa52066629da9d900e96c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..378c102f4916b0eebc9dde7a803b56165d333f96 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/1093a67aa29aa52066629da9d900e96c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4fbb341f1cf9456006cc57107ba44bb2dc525ff4217009124add3a2898a0e51c +size 62051 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/151de7a22267e747abab112051cee51a_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/151de7a22267e747abab112051cee51a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4e84d911d5075bcecd4526e364692319e946de33 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/151de7a22267e747abab112051cee51a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09c5e52ac8368334d5b82782c2ccbd6effd49e27e3644eb785e149e3dee771f8 +size 125894 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/1c82cd7cc9b8b8b3272bc7bbf4fd4135_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/1c82cd7cc9b8b8b3272bc7bbf4fd4135_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..071260f5ea2302162d109520f564fb11137fb394 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/1c82cd7cc9b8b8b3272bc7bbf4fd4135_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b2fb1f02d7b57162d09763f1a97c995b97e2d6c06b31744794a8e00d4052404a +size 12943 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/1dcfae33560a791008cdc9e3369d4e0f_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/1dcfae33560a791008cdc9e3369d4e0f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..67597419c2c0c6a9b779f3625bf165f7d8701b1a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/1dcfae33560a791008cdc9e3369d4e0f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:be8045dff0a14cdd7073cf5fbdfce0140e0941c49e8b60e532a36e9f34eb40e1 +size 41121 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/2240d9b17f5f48318f32b9484da814c4_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/2240d9b17f5f48318f32b9484da814c4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c4483ae284a4e7ee94a9c4c745e3379002566fec --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/2240d9b17f5f48318f32b9484da814c4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:72a8b9f49b67533a6339eb1f5e236b1ce44089cf731da40b953f50f66a0ac32c +size 144995 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/2d14511a46b674961a8454738d010808_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/2d14511a46b674961a8454738d010808_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3e6704efe94cacfb5af3c0471f91c9fe8db47ec --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/2d14511a46b674961a8454738d010808_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4a983904b89f3896499b5c416dae4440147d9fdc4543998fb3ba1eb8a4a328d2 +size 109800 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/3b3b58663a746b109ceb09986e077a94_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/3b3b58663a746b109ceb09986e077a94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8910d6d5fa787b40ee439fa1b34e9d16e8ab8319 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/3b3b58663a746b109ceb09986e077a94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2ba79438cf6921f10d9d22de8b993869a10644acc3b5189088b3d908ec1481c9 +size 4536 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/3bb217d736e020dc19ab241b0cc068f1_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/3bb217d736e020dc19ab241b0cc068f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..107a3ad9f23a12163d397cb4e893035a71aa7607 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/3bb217d736e020dc19ab241b0cc068f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:03d3a2cdffee27a8f88fab7d6160caca25c076bed05e1e3f06ad599a4758b51c +size 63366 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/4df41130fff6f8a61a447cd22dbac6d6_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/4df41130fff6f8a61a447cd22dbac6d6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..382694027acb4f5dc940c1f2277c0886793fe630 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/4df41130fff6f8a61a447cd22dbac6d6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:853b18ea1e5793517663060afe96d74cf8faeb721c73b828f4da3d9086fe887f +size 90351 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/53fd4314b6c11a23275810dd5e13b019_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/53fd4314b6c11a23275810dd5e13b019_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..72202f9fde848b4263b7a89853d9aa09ab1b62ed --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/53fd4314b6c11a23275810dd5e13b019_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8b263f0dba1f09c39297a1060e788c0cc0dcc6f926d86b85e9c0433cc9613acf +size 11487 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/5f785f2d94ab0113d6fda962d269b24a_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/5f785f2d94ab0113d6fda962d269b24a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..93444e5afa3b9dc6dd51e31ddb5ca346ab03774a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/5f785f2d94ab0113d6fda962d269b24a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d3c33a3c7defde46a3f353de0791f5d43a9454b571a1d23253763ce23f75bbb2 +size 108867 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/6159b4922e8f70f4e640e09c82c5ecc4_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/6159b4922e8f70f4e640e09c82c5ecc4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..96151823926959ff4c593917dfe22d2611b133be --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/6159b4922e8f70f4e640e09c82c5ecc4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:709340d13c56a40aa3f3cd49721cfdf46f3bc8b5e7417f7003eb482abaa8ac8f +size 58123 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/61d84b465b9bbc737e54637bdea5ad37_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/61d84b465b9bbc737e54637bdea5ad37_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0e8dd55695f175a730e87dfa662b0b240fbc5a86 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/61d84b465b9bbc737e54637bdea5ad37_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a896e18d66fc054b4c56b5ceb52812e235c3fcfbc93eb982bc776110c4ae113e +size 45768 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/701324becb6fab516577009acecc7b8a_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/701324becb6fab516577009acecc7b8a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d04c6892a5ccbac0c3d81c7fbfdc7ac72d37654d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/701324becb6fab516577009acecc7b8a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:00df9545e522e3a63341b054015b7dc631c6f33e8c611140f31ec17c40510c6d +size 98450 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/73b30087c36e683b511e2d5aa4cd5a55_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/73b30087c36e683b511e2d5aa4cd5a55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fe1b635739d46a969832b9c41e0fb29d21003072 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/73b30087c36e683b511e2d5aa4cd5a55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2a40f4ccbb34633e4ed05a146a5388dbde5a3f646ca7f6caf314352442b4bcf2 +size 48311 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/7ea9cdba956cc18e13e5e69fa9f1830d_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/7ea9cdba956cc18e13e5e69fa9f1830d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d94ce6ff604839164be99a654698073298c20db --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/7ea9cdba956cc18e13e5e69fa9f1830d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c4723c5e7e94a08be6dca1d65d329591880312fe42e295c5c4847c17200ed70a +size 65933 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/80df01979f7b2317571d8dd77a170cc0_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/80df01979f7b2317571d8dd77a170cc0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..525a231f2061b97c0941113e720410985fc80e04 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/80df01979f7b2317571d8dd77a170cc0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e057eb5b464a407dec12676eb71cfff8753bd68431363a2b9de6f4b2297f66e +size 32045 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/8b245a6dacebb70627ad76c1c03809aa_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/8b245a6dacebb70627ad76c1c03809aa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..85712233f2b7546243557c18f9c15dc293fa7ec8 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/8b245a6dacebb70627ad76c1c03809aa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4489cc5f87a9510ff219a2d0701beb68e1640f085809bfece3e3b0ed4617b559 +size 48992 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/912801004a484f9c1deaa1c598fe178d_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/912801004a484f9c1deaa1c598fe178d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3866e958c687d1377c255989d2f4e851a6f28e7a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/912801004a484f9c1deaa1c598fe178d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a974833728cd13359fa3cc908db8f9f973730d069ff06816b6dd0c67cc38c365 +size 27883 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..08a9c509da7e591b85ce9c11c7659f729776badc --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e51e29a8c647908fe9f48f56b660f7378772dafa9202a271bcb2032f560fafe1 +size 4531 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/9f2241cf65acf8f26e299937b95a7d0d_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/9f2241cf65acf8f26e299937b95a7d0d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..058439c0bf06af19981afee2b658f92da6bd0610 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/9f2241cf65acf8f26e299937b95a7d0d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ea53420662fd53fc729aeddf90854a3e98d534449911b8532e9f3c6e66b13400 +size 50239 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/b75e2526fc69dcdc330bea8fdef3345a_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/b75e2526fc69dcdc330bea8fdef3345a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0737f1009dd4980212e7e384ef768e58a592677a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/b75e2526fc69dcdc330bea8fdef3345a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:39e11d490ef0ba8e75afda67149f98255b3bb3201af6566e176d907d469e8fb9 +size 60321 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/beedc235516f64a3ef7524129003fb89_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/beedc235516f64a3ef7524129003fb89_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6794c58276efb7479710fe33ce9cc8615b49789e --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/beedc235516f64a3ef7524129003fb89_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e8172d6eb19efb8fd5f6801ca46ff7491409bde8c20291470abe2687a4a4e847 +size 51385 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/c3a65b457676a37b38f779a731b083b9_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/c3a65b457676a37b38f779a731b083b9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7652917d6c633a7efc8123eee23b0d02ea377d34 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/c3a65b457676a37b38f779a731b083b9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f0b09df511d43ddbab279d7129be7745b58cfb3675f251f072272f9d779b6b63 +size 49390 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2b90693e69025867d0dd05d8f98d4ef9b4bf8d2 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ed2f1f4ac06a8bc6ac44f6e3f61e762e6c8489952cf16d65bfea30fe61adb2af +size 4677 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d5642ca291e5e00ad8bb543aa273595d_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d5642ca291e5e00ad8bb543aa273595d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..50c141fdd91121709fbc4511035b0982cf73be26 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d5642ca291e5e00ad8bb543aa273595d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:140a801230b8475e6ff2f9fa8f711c7ae278c9d6ed3400a7b7a74feaa504e4bf +size 4518 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d5a595988c6a8e0e664f5f1bfe9839d3_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d5a595988c6a8e0e664f5f1bfe9839d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e9f5f3e782ae0b7d8576cbaf8c41069f0074cc2d --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d5a595988c6a8e0e664f5f1bfe9839d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ad198937539f1144f13e67fc35fba0299f3621cab0349427a343897c9b4f002a +size 59101 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2607b0eef27677fb38e9fdbba214fde5d86a7f72 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9e383e92647a2356488a833110e26ad296a5dd136dd01f365e78a67474a8258 +size 4548 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2d377a7b1ecc3d90d66455a89af93a9d69c05c2 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f53afab4ac078add52c3f0b2a3b8709940df75f38907b6df0bd3e7c4b98620ac +size 4528 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/e142b941b0051cd6913e4df54f0b9357_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/e142b941b0051cd6913e4df54f0b9357_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8bbf77a221220439aab576a22f0d131f3e383234 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/e142b941b0051cd6913e4df54f0b9357_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9a4d86de4117e76283b8c61291b8d6ca30a3a83a40744db084ae2e9277b9ad6a +size 64872 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/e23ed687a01eaff22dd1303a95efed85_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/e23ed687a01eaff22dd1303a95efed85_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c7ef4b430b9c1097d416b8aa4573ee9f2eb1babd --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/e23ed687a01eaff22dd1303a95efed85_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:03572b55217b4d6549948ef996f5374fd548db196df72684a42f74c3970d5599 +size 86444 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/e8d50d4e356e9bf73e34786dd1ef28a0_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/e8d50d4e356e9bf73e34786dd1ef28a0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4651b083c9c40f996661f48e5569a15effac3279 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/e8d50d4e356e9bf73e34786dd1ef28a0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9a1c3146b23806c939d2c245c8214494173cf634768b0c3bb5de75d27f5ba22d +size 45331 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/f57787850f7b49f95e84debdc363e80b_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/f57787850f7b49f95e84debdc363e80b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..37d0b5290e22f3d14418be7d664d74ae92591af7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/f57787850f7b49f95e84debdc363e80b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b4fcba9513fed6cadb9a6812755589745a1c5c8f71ff6127716ffdee88b9a86f +size 92493 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/f8ba41cd734ca6784393b8f3692e01aa_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/f8ba41cd734ca6784393b8f3692e01aa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..128ceaa76c73b302022a3f6a62604ca695d10093 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/f8ba41cd734ca6784393b8f3692e01aa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:272f6d22570edbfc54886e4de1a5a34056c09aa425f6b40308dd70ffab4039cb +size 42013 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/fb6ca624f4768f0cf25836da8120f9c3_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/fb6ca624f4768f0cf25836da8120f9c3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..661e81959b0a613fe1c23d9b7ddcfa9f45065c92 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/fb6ca624f4768f0cf25836da8120f9c3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:51c7358690da22bb433f350942966436e70c7f5fc8b25c8d220a438ec3318d16 +size 61602 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/fef3b43ed51cd6cb2d3bbadc5549553d_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/fef3b43ed51cd6cb2d3bbadc5549553d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f2e50766e55dd374a638b2cdd53d0dc74a5b170a --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/fef3b43ed51cd6cb2d3bbadc5549553d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9a49266f5ef8628e16f1da861b87b5a9490c779eab0258a60f557245f5bc2157 +size 4575 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/raw.md b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..61a51ed2f4b438fa9de80bb2e5aefeb0e45fc9c0 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00/raw.md @@ -0,0 +1,3164 @@ + + +![O-RAN Alliance logo](fef3b43ed51cd6cb2d3bbadc5549553d_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN ALLIANCE' in blue and black. + +O-RAN Alliance logo + +O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00 + +Technical Specification + +# **O-RAN Work Group 6 (Cloudification and Orchestration Workgroup)** + +# **O-Cloud Information Model** + +# --- Contents + +| | | +|----------------------------------------------------------------|-----| +| List of figures ..... | 3 | +| List of tables ..... | 3 | +| Foreword..... | 6 | +| Modal verbs terminology ..... | 6 | +| Executive summary ..... | 6 | +| Introduction ..... | 6 | +| 1 Scope ..... | 7 | +| 2 References ..... | 7 | +| 2.1 Normative references ..... | 7 | +| 2.2 Informative references ..... | 8 | +| 3 Definition of terms, symbols and abbreviations ..... | 8 | +| 3.1 Terms ..... | 8 | +| 3.2 Symbols ..... | 8 | +| 3.3 Abbreviations..... | 8 | +| 4 O-Cloud Information Model ..... | 9 | +| 4.1 Information Modeling Conventions..... | 9 | +| 4.1.1 Modeling approach, Unified Modeling Language (UML) ..... | 9 | +| 4.1.2 Namespaces in the Information Model..... | 9 | +| 4.1.3 Namespace Relationships ..... | 9 | +| 4.2 Information Model Definitions ..... | 10 | +| 4.2.1 Namespace: ORAN.O2ims.Inventory ..... | 10 | +| 4.2.2 Namespace: ORAN.O2ims.Artifacts ..... | 76 | +| 4.2.3 Namespace: ORAN.O2ims.Cluster ..... | 80 | +| 4.2.4 Namespace: ORAN.O2ims.Provisioning..... | 90 | +| 4.2.5 Namespace: ORAN.O2ims.Infrastructure ..... | 94 | +| Annex (informative): Change History ..... | 108 | + +# List of figures + +| | | +|--------------------------------------------------------------------------------------------------------------------------------------|----| +| Figure 4.1.3-1 Relationship between Namespaces ..... | 9 | +| Figure 4.2.1.3.1.2-1 O2ims Inventory Objects Relationship Views..... | 12 | +| Figure 4.2.1.3.1.2-2 O2ims Inventory Event Subscribe/Notify Relationship View..... | 13 | +| Figure 4.2.1.3.1.3.1-1 O2ims Alarm Relationship View ..... | 13 | +| Figure 4.2.1.3.1.3.2-1 Performance Monitoring Information Flow ..... | 14 | +| Figure 4.2.1.3.1.3.2-2 O2ims Performance Store Relationship View..... | 15 | +| Figure 4.2.1.3.1.3.2-3 O2ims Performance Measurement Job Relationship View ..... | 16 | +| Figure 4.2.1.3.1.3.2-4 O2ims Performance Subscription Relationship View ..... | 17 | +| Figure 4.2.1.3.1.3.2-5 O2ims Performance Report Relationship View ..... | 18 | +| Figure 4.2.1.3.1.4.1-1 illustrates the O-Cloud networking-related Resource relationships between the Information Object Classes..... | 20 | +| Figure 4.2.1.3.1.4.2-1 illustrates the Hardware Layer View and networking related Information Object Classes ..... | 21 | +| Figure 4.2.1.3.1.4.2-3-1 illustrates the Execution Environment Layer View and networking related Information Object Classes..... | 22 | +| Figure 4.2.1.3.2.1-1 O2ims Inventory Intra-Namespace Inheritance ..... | 22 | +| Figure 4.2.1.3.2.1-2 O2ims Inventory Inter-Namespace Inheritance ..... | 23 | +| Figure 4.2.1.3.2.2-1 O2ims Alarm Inheritance..... | 23 | +| Figure 4.2.1.3.2.2-1 O2ims Performance Inheritance ..... | 23 | +| Figure 4.2.1.4.16.4-1 State & Status Diagram for PerformanceMeasurementJob ..... | 50 | +| Figure 4.2.2.3.1.2-1 ORAN.O2ims.Artifacts Intra-Namespace Relationships ..... | 77 | +| Figure 4.2.2.3.1.3-1 ORAN.O2ims.Artifacts Inter-Namespace Relationships ..... | 77 | +| Figure 4.2.2.3.2.1-1 ORAN.O2ims.Artifacts Inheritance ..... | 78 | +| 4.2.3.3.1.2-1 ORAN.O2ims.Cluster Intra-Namespace Relationships..... | 82 | +| Figure 4.2.3.3.1.3-1 ORAN.O2ims.Cluster Inter-Namespace Relationships..... | 82 | +| Figure 4.3.2.2.2.1-1 ORAN.O2ims.Cluster Inheritance ..... | 83 | +| Figure 4.2.4.3.1.2-1 ORAN.O2ims.Provisioning Intra-Namespace Relationships ..... | 91 | +| Figure 4.2.4.3.1.3-1 ORAN.O2ims.Provisioning Inter-Namespace Relationships ..... | 91 | +| Figure 4.2.4.3.2.1-1 ORAN.O2ims.Provisioning Inheritance ..... | 91 | +| Figure 4.2.5.3.1.2-1 O-Cloud Networking Overview..... | 96 | +| Figure 4.2.5.3.1.2-2 ORAN.O2ims.Infrastructure Intra-Namespace Relationships..... | 97 | +| Figure 4.2.5.3.1.3-1 ORAN.O2ims.Infrastructure Inter-Namespace Relationships..... | 97 | +| Figure 4.2.5.3.2.1-1 ORAN.O2ims.Infrastructure Inheritance ..... | 98 | + +# List of tables + +| | | +|------------------------------------------------------------------|----| +| Table 4.2.1.2.1-1 Imported Entities ..... | 10 | +| Table 4.2.1.2.2-1 Associated Entities ..... | 10 | +| Table 4.2.1.4.1.2-1 Attributes Properties for OCloud ..... | 24 | +| Table 4.2.1.4.2.2-1 Attributes Properties for ResourceType ..... | 26 | +| Table 4.2.1.4.3.2-1 Attributes Properties for ResourcePool ..... | 28 | +| Table 4.2.1.4.4.2-1 Attributes Properties for Resource ..... | 29 | + +| | | +|--------------------------------------------------------------------------------------------------|----| +| Table 4.2.1.4.5.2-1 Attributes Properties for DeploymentManager ..... | 31 | +| Table 4.2.1.4.6.2-1 Attributes Properties for InventorySubscription ..... | 33 | +| Table 4.2.1.4.8.1-1 InfrastructureInventoryEvent Requirements ..... | 35 | +| Table 4.2.1.4.8.2-1 Attributes Properties for InfrastructureInventoryEvent ..... | 35 | +| Table 4.2.1.4.9.1-1 OCloudAvailableNotification Requirements ..... | 36 | +| Table 4.2.1.4.9.2-1 Attributes Properties for OCloudAvailableNotification ..... | 37 | +| Table 4.2.1.4.10.1-1 AlarmEventRecord Requirements ..... | 38 | +| Table 4.2.1.4.10.2-1 Attributes Properties for AlarmEventRecord ..... | 38 | +| Table 4.2.1.4.11.1-1 AlarmEvent Requirements ..... | 40 | +| Table 4.2.1.4.11.2-1 Attributes Properties for AlarmEvent ..... | 40 | +| Table 4.2.1.4.12.1-1 Subscription Requirements ..... | 41 | +| Table 4.2.1.4.12.2-1 Attributes Properties for AlarmSubscription ..... | 41 | +| Table 4.2.1.4.13.1-1 AlarmList Requirements ..... | 43 | +| Table 4.2.1.4.13.2-1 Attributes Properties for AlarmList ..... | 43 | +| Table 4.2.1.4.14.2-1 Attributes Properties for PerformanceMeasurementStore ..... | 44 | +| Table 4.2.1.4.15.2-1 Attributes Properties for PerformanceMeasurementRecord ..... | 45 | +| Table 4.2.1.4.16.1-1 PerformanceMeasurementJob Requirements ..... | 46 | +| Table 4.2.1.4.16.2-1 Attributes Properties for PerformanceMeasurementJob ..... | 46 | +| Table 4.2.1.4.16.3-1 Attributes Constraints for PerformanceMeasurementJob ..... | 50 | +| Table 4.2.1.4.17.2-1 Attributes Properties for MeasuredResource ..... | 50 | +| Table 4.2.1.4.18.2-1 Attributes Properties for CollectedMeasurement ..... | 52 | +| Table 4.2.1.4.19.2-1 Attributes Properties for PerformanceMeasurementJobChangeSubscription ..... | 53 | +| Table 4.2.1.4.20.2-1 Attributes Properties for PerformanceMeasurementJobChangeNotification ..... | 55 | +| Table 4.2.1.4.21.1-1 PerformanceSubscription Requirements ..... | 56 | +| Table 4.2.1.4.21.2-1 Attributes Properties for PerformanceSubscription ..... | 56 | +| Table 4.2.1.4.22.2-1 Attributes Properties for PerformanceReportingFrequency ..... | 59 | +| Table 4.2.1.4.23.2-1 Attributes Properties for PerformanceSubscriptionCriteria ..... | 61 | +| Table 4.2.1.4.24.1-1 PerformanceMeasurementReport Requirements ..... | 62 | +| Table 4.2.1.4.24.2-1 Attributes Properties for PerformanceMeasurementReport ..... | 62 | +| Table 4.2.1.4.25.2-1 Attributes Properties for JobReport ..... | 64 | +| Table 4.2.1.4.26.2-1 Attributes Properties for ResourceReport ..... | 65 | +| Table 4.2.1.4.27.2-1 Attributes Properties for MeasurementValue ..... | 66 | +| Table 4.2.1.4.28.2-1 Attributes Properties for NotifyFileReady ..... | 67 | +| Table 4.2.1.4.29.2-1 Attributes Properties for FileInfo ..... | 69 | +| Table 4.2.1.4.30.2-1 Attributes Properties for Location ..... | 70 | +| Table 4.2.1.4.31.2-1 Attributes Properties for OCloudSite ..... | 72 | +| Table 4.2.1.4.32.2-1 Attributes Properties for LogQuery ..... | 73 | +| Table 4.2.1.4.33.2-1 Attributes Properties for DateRange ..... | 75 | +| Table 4.2.1.4.33.3-2 Attributes Constraints for DateRange ..... | 75 | +| Table 4.2.2.2.1-1 Imported Entities ..... | 76 | +| Table 4.2.2.2.2-1 Associated Entities ..... | 76 | +| Table 4.2.3.2.1-1 Imported Entities ..... | 81 | +| Table 4.2.3.2.2-1 Associated Entities ..... | 81 | +| Table 4.2.3.4.1.2-1 Attributes Properties for NodeClusterType ..... | 83 | +| Table 4.2.3.4.1.2-1 Attributes Properties for NodeCluster ..... | 84 | +| Table 4.2.3.4.3.2-1 Attributes Properties for ClusterResourceType ..... | 86 | +| Table 4.2.3.4.4.2-1 Attributes Properties for ClusterResource ..... | 87 | +| Table 4.2.3.4.5.2-1 Attributes Properties for ClusterResourceGroup ..... | 89 | + +| | | +|--------------------------------------------------------------------------------|-----| +| Table 4.2.4.2.1-1 Imported Entities ..... | 90 | +| Table 4.2.4.2.2-1 Associated Entities ..... | 90 | +| Table 4.2.4.4.1.2-1 Attributes Properties for ProvisioningRequest ..... | 92 | +| Table 4.2.4.4.1.3-1 Attributes Constraints for ProvisioningRequest ..... | 93 | +| Table 4.2.4.4.2.2-1 Attributes Properties for ProvisioningStatus ..... | 94 | +| Table 4.2.5.2.1-1 Imported Entities ..... | 95 | +| Table 4.2.5.2.2-1 Associated Entities ..... | 95 | +| Table 4.2.5.4.1.2-1 Attributes Properties for InfrastructureResourceType ..... | 98 | +| Table 4.2.5.4.1.2-1 Attributes Properties for InfrastructureResource ..... | 99 | +| Table 4.2.5.4.3.2-1 Attributes Properties for Gateway ..... | 101 | +| Table 4.2.5.4.4.2-1 Attributes Properties for SiteNetwork ..... | 102 | +| Table 4.2.5.4.5.2-1 Attributes Properties for AttachmentCircuit ..... | 104 | +| Table 4.2.5.4.6.2-1 Attributes Properties for Port ..... | 105 | +| Table 4.2.5.4.7.2-1 Attributes Properties for SegmentationElement ..... | 106 | +| Table 4.2.5.4.8.2-1 Attributes Properties for NetworkAddress ..... | 106 | +| Table 4.2.5.4.8.3-1 Attributes Constraints for EndPoint ..... | 107 | + +# --- Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +--- + +# Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Executive summary + +The O-Cloud Information Model provides the logical model of information elements and their relationships. This includes: + +- Enumerations which provide a predefined list of choices. + - Information Object Classes intended to convey classes that can become an Information Object + - Data Types which provide structure to the elements of an Information Object Class + - Notifications which is the information conveyed in a message from a service publisher to a service consumer +- + +# Introduction + +The O2 interface exposes information about the O-Cloud to external clients, presumably the SMO as the primary consumer. There are many relationships between elements of the model which need to be captured. + +The O-Cloud Information Model is based on the 3GPP process defined to document a Network Resource Model (NRM). The content contains all the salient elements of the NRM but does not follow the strict outline defined in 3GPP TS 32.160 [i.1]. The outline has been modified to align with other WG6 documents and to eliminate duplicative maintenance which leads to discord within the model. + +UML provides a rich set of concepts, notations, and model elements to model distributive systems. 3GPP TS 32.156 [1] provides the necessary and sufficient set of UML notations and model elements, including the ones built by the UML extension mechanism <<stereotype>> to model network management systems and their managed nodes. These conventions are applied to the O-Cloud Information Model. + +The Information model uses embedded PlantUML for diagramming. The information model relationships are modeled using UML Class diagram conventions. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +**This document is both a Specification and an Informational Report in that it specifies the Information Model that is foundational for O-RAN's model-driven architecture for the O-Cloud information exposed over the O2 interface.** + +**In addition, this document includes information about existing standards and industry work that serve as a basis for work items in O-RAN.** + +**Lastly, this document describes the de facto methods and procedures with respect to a “modeling continuum” that aims to establish and evolve an O-Cloud Information Model from which O-RAN Data Models may be generated manually or with a set of tools.** + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] 3GPP TS 32.156: Telecommunication management; Fixed Mobile Convergence (FMC) Model repertoire +- [2] O-RAN.WG10.Information Model and Data Models.0; O-RAN Information Model and Data Models Specification; + +- [3] O-RAN.WG6.ORCH-USE-CASES, Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN; +- [4] OMG: "Unified Modelling Language Specification, Version 2.5.1". +<https://www.omg.org/spec/UML/2.5.1>; +- [5] IETF RFC 5424 : The Syslog Protocol ; March 2009 + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in 3GPP Release 18. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TS 32.160: Management and orchestration; Management service template +- [i.2] O-RAN.WG6.O2-GA&P, O2 Interface General Aspects and Principles; +- [i.3] O-RAN.WG6.CADS, Cloud Architecture and Deployment Scenarios; + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +- | | | +|--------------------|-----------------------------------------------------------------------------------| +| Generalized Object | This is a kind of object whereby specialized objects can be derived from. | +| Specialized Object | This is a kind of object which is derived from one or more Generalized Object(s). | + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +## 3.3 Abbreviations + +For the purposes of the present document, the [following] abbreviations [given in ... and the following] apply: + +AAL Accelerator Abstraction Layer +OIM O-Cloud Information Model + +# 4 O-Cloud Information Model + +## 4.1 Information Modeling Conventions + +### 4.1.1 Modeling approach, Unified Modeling Language (UML) + +The Information Model within O-Cloud Infrastructure shall use the Unified Modeling Language™ (UML®) version 2.5.1 [4] from the Object Management Group (OMG). + +The O-Cloud Infrastructure Information Model shall follow methodology documented in 3GPP TS 32.160 [i.1] Clause 5.2. + +### 4.1.2 Namespaces in the Information Model + +A Namespace provides a container for named elements, which are called its members. A Namespace may also import named elements from other specifications, in which case those elements become members of the importing Namespace. + +### 4.1.3 Namespace Relationships + +Figure 4.1.3-1 describes the relationship between each namespace defined in this specification. + +![Figure 4.1.3-1 Relationship between Namespaces. A diagram showing the relationships between five namespaces: O-Cloud Provisioning, O-Cloud (Managed) Node Clusters, O-Cloud (Managed) Infrastructure, (Exposed) O-Cloud Resources, and O-Cloud Artifacts. Arrows indicate 'Fulfilled by', 'Use', and 'Based on' relationships. A note explains that Node Cluster and Infrastructure are based on the Artifacts Template.](2240d9b17f5f48318f32b9484da814c4_img.jpg) + +The diagram illustrates the relationships between five namespaces defined in the specification: + +- O-Cloud Provisioning** (Red box): + - Provisioning Requests with ID + - Object is LCM:ed as long as there is a Requirement (SLO) + - SMO -> O-Cloud + - Point to a Template + - Include issued Template Parameters + - O-Cloud -> SMO + - Request Creation/Update Status + - Point to referenced Cluster and Infrastructure resources +- O-Cloud (Managed) Node Clusters** (Blue box): + - Have a NodeClusterResourceTypes + - Have Cluster Resources of ClusterResourceTypes + - Use consumable Resources (from Inventory) + - Incur indirect "costs" based on allocated Resources (from Inventory) + - Have status on composed Cluster Resources + - Have metrics on composed Cluster Resources + - E.g. NodeClusters, Nodes, NodeGroups, NodeClusterSiteNWs, DeploymentManagers? +- O-Cloud (Managed) Infrastructure** (Light blue box): + - Have a InfrastructureResourceTypes + - Have Infrastructure Resources of InfrastructureResourceTypes + - Use consumable Resources (from Inventory) + - Incur indirect "costs" based on allocated Resources (from Inventory) + - Have status on composed Infrastructure + - Have metrics on composed Infrastructure + - E.g. O-CloudGWs, SiteNWs and AttachmentCircuits +- (Exposed) O-Cloud Resources** (Yellow box): + - Consumables (finite availability) + - Incur some sort of "costs" + - Have "reality-based" status + - Have "reality-based" metrics + - Have a ResourceType descriptions + - E.g. Servers, VMs, Accelerators, Networks, Gateways, Storages +- O-Cloud Artifacts** (Pink box): + - Have Artifact Resources of ArtifactResourceTypes + - Not consumable + - Incur no "costs" + - Don't have status + - Don't have metrics + - E.g. Templates, Blueprints, SW, FW, Config bundles, files, images, libraries + +Relationships: + +- O-Cloud Provisioning** is **Fulfilled by** **O-Cloud (Managed) Infrastructure**. +- O-Cloud Provisioning** is **Fulfilled by** **O-Cloud (Managed) Node Clusters**. +- O-Cloud (Managed) Node Clusters** **Use** **(Exposed) O-Cloud Resources**. +- O-Cloud (Managed) Node Clusters** **Use** **O-Cloud Artifacts**. +- O-Cloud (Managed) Infrastructure** **Use** **(Exposed) O-Cloud Resources**. +- O-Cloud (Managed) Infrastructure** **Use** **O-Cloud Artifacts**. +- O-Cloud (Managed) Infrastructure** is **Based on** **O-Cloud Artifacts**. + +Additional notes: + +- O-Cloud provided Managed Cluster services.** (Yellow callout pointing to Node Clusters) +- O-Cloud provided Managed Infrastructure services.** (Yellow callout pointing to Infrastructure) +- \*) Node Cluster and Infrastructure are based on the Artifacts Template that is pointed out by the ProvisioningRequest and not directly from any Node Cluster or Infrastructure attributes/references** + +Figure 4.1.3-1 Relationship between Namespaces. A diagram showing the relationships between five namespaces: O-Cloud Provisioning, O-Cloud (Managed) Node Clusters, O-Cloud (Managed) Infrastructure, (Exposed) O-Cloud Resources, and O-Cloud Artifacts. Arrows indicate 'Fulfilled by', 'Use', and 'Based on' relationships. A note explains that Node Cluster and Infrastructure are based on the Artifacts Template. + +Figure 4.1.3-1 Relationship between Namespaces + +## 4.2 Information Model Definitions + +### 4.2.1 Namespace: ORAN.O2ims.Inventory + +#### 4.2.1.1 Namespace Overview + +The O-RAN O2ims Inventory namespace defines the classes and their attributes which are directly exposed to the consumer (SMO) via its O2 IMS Interface. + +This namespace is used for O-Cloud infrastructure Resources. That content is meant only to be internally consumable to the O-Cloud. The O2ims Inventory has status, metrics and types as well as its topologies. These resources can be used to build up the O-Cloud Node Clusters and their compute, networking and storage capabilities. + +#### 4.2.1.2 Imported and associated information entities + +##### 4.2.1.2.1 Imported information entities and local labels + +Information entities imported into the model are also elements of the namespace and therefore shall remain unique within the namespace. + +**Table 4.2.1.2.1-1 Imported Entities** + +| Label reference | Local label | +|----------------------------------------------|-------------| +| TS 28.622 [6], information object class, Top | Top | +| | | + +##### 4.2.1.2.2 Associated information entities and local labels + +Information entities referenced in the model through an association which may be extended and overloaded with a new entity of the same name within the namespace are listed in the associated entities table. + +**Table 4.2.1.2.2-1 Associated Entities** + +| Label reference | Local label | +|------------------------------------------------------|------------------------------| +| WG10 IM/DM [2], PerformanceMeasureDictionary | PerformanceMeasureDictionary | +| WG10 IM/DM [2], <i>PerformanceMeasureDefinition_</i> | PerformanceMeasureDefinition | +| WG10 IM/DM [2], AlarmDictionary | AlarmDictionary | +| WG10 IM/DM [2], AlarmDefinition | AlarmDefinition | +| WG10 IM/DM [2], ProbableCause | ProbableCause | +| 4.2.2.4.1, ArtifactResourceType | ArtifactResourceType | +| 4.2.2.4.1, ArtifactResource | ArtifactResource | +| 4.2.3.4.1, ClusterResourceType | ClusterResourceType | +| 4.2.3.4.2, ClusterResource | ClusterResource | +| 4.2.3.4.3, NodeClusterType | NodeClusterType | +| 4.2.3.4.4, NodeCluster | NodeCluster | +| 4.2.4.4.1, InfrastructureResourceType | InfrastructureResourceType | +| 4.2.4.4.2, InfrastructureResource | InfrastructureResource | + +#### 4.2.1.3 Class Diagram + +##### 4.2.1.3.1 Relationships + +###### 4.2.1.3.1.1 Description + +This clause depicts the set of classes (e.g. IOCs) that encapsulates the information relevant for the O-RAN Cloud (O-Cloud). This clause provides an overview of the relationships between relevant classes in UML. Subsequent clauses provide more detailed specification of various aspects of these classes. The UML Class diagram depicts a view of the namespace maintaining a defined focus so as not to overcrowd a single diagram trying to depict all relationships within the namespace. + +###### 4.2.1.3.1.2 O2ims Inventory Object Relationships + +The O2ims services have operations on the following managed service objects that are provided by the O-Cloud: + +- OCloud, +- Location, +- OCloudSite, +- ResourceType, +- ResourcePool, +- Resource, +- DeploymentManager, and +- InventoryChangeSubscription + +Figure 4.2.1.3.1.2-1 illustrates the relationships in between the information entities of the O2ims\_InfrastructureInventory services. Figure 4.2.1.3.1.2-2 illustrates the relationship for the subscribe/notify pattern. + +![UML class diagram showing the relationship between O2ims Inventory objects and Management Artifacts. The diagram includes classes like O-Cloud, O-CloudSite, ResourcePool, Resource, ResourceType, AlarmDictionary, and PerformanceDictionary, along with their associations and multiplicities.](701324becb6fab516577009acecc7b8a_img.jpg) + +**ORAN.O2ims.Inventory** + +**ORAN.ManagementArtifacts** + +``` + +classDiagram + class OCloudAvailableNotification["«notification»\nOCloudAvailableNotification"] + class OCloud["O-Cloud"] + class OCloudSite["O-CloudSite"] + class Location + class DeploymentManager + class ResourcePool + class Resource + class ResourceType + class AlarmDictionary + class PerformanceDictionary + class ResourceKind["«enumeration»\nResourceKind"] + class ResourceClass["«enumeration»\nResourceClass"] + + OCloudAvailableNotification ..> OCloud : SendsOnCreation + OCloud "1" -- "1..*" OCloudSite : +OCloudSites + OCloud "1" -- "1..*" DeploymentManager : +deploymentManagers + OCloudSite --> Location : DeployedAt + OCloudSite "1" -- "1..*" ResourcePool : +resourcePools + ResourcePool "1" -- "1..*" Resource : +resources + Resource "1" -- "0..*" Resource : IsComposedOf + Resource "0..*" -- "0..*" ResourceType : +elements + ResourceType "1..*" -- "0..*" Resource : +resourceTypes + ResourceType "1" -- "0..1" AlarmDictionary : +alarmDictionary + ResourceType "1" -- "0..1" PerformanceDictionary : +performanceDictionary + ResourceType --> ResourceKind + ResourceType --> ResourceClass + +``` + +The diagram illustrates the relationships between O2ims Inventory objects and Management Artifacts. The **ORAN.O2ims.Inventory** package contains the following classes and relationships: + +- O-Cloud** (1) is associated with **O-CloudSite** (1..\*) via the **+OCloudSites** association. +- O-Cloud** (1) is associated with **DeploymentManager** (1..\*) via the **+deploymentManagers** association. +- O-CloudSite** is associated with **Location** via the **DeployedAt** association. +- O-CloudSite** (1) is associated with **ResourcePool** (1..\*) via the **+resourcePools** association. +- ResourcePool** (1) is associated with **Resource** (1..\*) via the **+resources** association. +- Resource** (1) is associated with **Resource** (0..\*) via the **IsComposedOf** association. +- Resource** (0..\*) is associated with **ResourceType** (0..\*) via the **+elements** association. +- ResourceType** (1..\*) is associated with **Resource** (0..\*) via the **+resourceTypes** association. +- ResourceType** (1) is associated with **AlarmDictionary** (0..1) via the **+alarmDictionary** association. +- ResourceType** (1) is associated with **PerformanceDictionary** (0..1) via the **+performanceDictionary** association. +- ResourceType** is associated with **ResourceKind** (enumeration) and **ResourceClass** (enumeration). + +The **ORAN.ManagementArtifacts** package contains the following classes: + +- AlarmDictionary** +- PerformanceDictionary** + +The **«notification» OCloudAvailableNotification** class is associated with **O-Cloud** via the **SendsOnCreation** association. + +UML class diagram showing the relationship between O2ims Inventory objects and Management Artifacts. The diagram includes classes like O-Cloud, O-CloudSite, ResourcePool, Resource, ResourceType, AlarmDictionary, and PerformanceDictionary, along with their associations and multiplicities. + +Figure 4.2.1.3.1.2-1 O2ims Inventory Objects Relationship Views + +![Figure 4.2.1.3.1.2-2 O2ims Inventory Event Subscribe/Notify Relationship View. This UML diagram shows the relationships between InventorySubscription, InfrastructureInventoryEvent, InfrastructureInventoryObject, and various resource types. InventorySubscription (1) creates (Subscription_Creates_Notification) InfrastructureInventoryEvent (*). InfrastructureInventoryEvent is a notification and is associated with NotificationEventType (enumeration). InfrastructureInventoryEvent has priorObjectState (0..1) and postObjectState (0..1) relationships with InfrastructureInventoryObject (*). InfrastructureInventoryObject is a base class for Resource, ResourceType, ResourcePool, DeploymentManager, O-Cloud, Location, and O-CloudSite.](fb6ca624f4768f0cf25836da8120f9c3_img.jpg) + +``` + +classDiagram + class InventorySubscription + class InfrastructureInventoryEvent["«notification» InfrastructureInventoryEvent"] + class NotificationEventType["«enumeration» NotificationEventType"] + class InfrastructureInventoryObject["InfrastructureInventoryObject_"] + class Resource + class ResourceType + class ResourcePool + class DeploymentManager + class OCloud["O-Cloud"] + class Location + class OCloudSite["O-CloudSite"] + + InventorySubscription "1" --> "*" InfrastructureInventoryEvent : Subscription_Creates_Notification + InfrastructureInventoryEvent .. NotificationEventType + InfrastructureInventoryEvent "*" --> "*" InfrastructureInventoryObject : +priorObjectState 0..1, +postObjectState 0..1 + InfrastructureInventoryObject <|-- Resource + InfrastructureInventoryObject <|-- ResourceType + InfrastructureInventoryObject <|-- ResourcePool + InfrastructureInventoryObject <|-- DeploymentManager + InfrastructureInventoryObject <|-- OCloud + InfrastructureInventoryObject <|-- Location + InfrastructureInventoryObject <|-- OCloudSite + +``` + +Figure 4.2.1.3.1.2-2 O2ims Inventory Event Subscribe/Notify Relationship View. This UML diagram shows the relationships between InventorySubscription, InfrastructureInventoryEvent, InfrastructureInventoryObject, and various resource types. InventorySubscription (1) creates (Subscription\_Creates\_Notification) InfrastructureInventoryEvent (\*). InfrastructureInventoryEvent is a notification and is associated with NotificationEventType (enumeration). InfrastructureInventoryEvent has priorObjectState (0..1) and postObjectState (0..1) relationships with InfrastructureInventoryObject (\*). InfrastructureInventoryObject is a base class for Resource, ResourceType, ResourcePool, DeploymentManager, O-Cloud, Location, and O-CloudSite. + +**Figure 4.2.1.3.1.2-2 O2ims Inventory Event Subscribe/Notify Relationship View** + +###### 4.2.1.3.1.3 Infrastructure Monitoring Relationships + +###### 4.2.1.3.1.3.1 Infrastructure Fault Relationships + +The O2ims\_InfrastructureMonitoring services has operations on the following managed service objects that are provided by the O-Cloud for faults: + +- AlarmList +- AlarmSubscription +- LogQuery + +Figure 4.2.1.3.1.3.1 -1 illustrates the relationships in between the information entities of the O2ims\_InfrastructureMonitoring fault services. + +![Figure 4.2.1.3.1.3.1-1 O2ims Alarm Relationship View. This UML diagram shows the relationships between LogQuery, AlarmSubscription, AlarmList, ResourceType, AlarmEvent, AlarmEventRecord, AlarmNotificationType, PerceivedSeverity, DateRange, NotifyFileReady, ProbableCause, and AlarmDefinition. LogQuery (0..*) has a dateRanges relationship with DateRange (data type) and a MayCreate relationship with NotifyFileReady (notification). AlarmSubscription creates AlarmEvent (notification). AlarmList has many AlarmEventRecords. AlarmEventRecord is associated with AlarmEvent, ResourceType, Resource, AlarmNotificationType, and PerceivedSeverity. AlarmEventRecord is diagnosed as ProbableCause and defined by AlarmDefinition in the ManagementArtifacts package.](1093a67aa29aa52066629da9d900e96c_img.jpg) + +``` + +classDiagram + class LogQuery + class AlarmSubscription + class AlarmList + class ResourceType + class AlarmEvent["«notification» AlarmEvent"] + class AlarmEventRecord["«data type» AlarmEventRecord"] + class AlarmNotificationType["«enumeration» AlarmNotificationType"] + class PerceivedSeverity["«enumeration» PerceivedSeverity"] + class DateRange["«data type» DateRange"] + class NotifyFileReady["«notification» NotifyFileReady"] + class ProbableCause + class AlarmDefinition + + LogQuery "0..*" --> "1" DateRange : +dateRanges + LogQuery --> NotifyFileReady : MayCreate + AlarmSubscription --> AlarmEvent : Creates + AlarmList --> AlarmEventRecord : HasMany + AlarmEventRecord --> AlarmEvent + AlarmEventRecord --> ResourceType + AlarmEventRecord --> Resource + AlarmEventRecord --> AlarmNotificationType + AlarmEventRecord --> PerceivedSeverity + AlarmEventRecord --> ProbableCause : IsDiagnosedAs + AlarmEventRecord --> AlarmDefinition : IsDefinedByA + +``` + +Figure 4.2.1.3.1.3.1-1 O2ims Alarm Relationship View. This UML diagram shows the relationships between LogQuery, AlarmSubscription, AlarmList, ResourceType, AlarmEvent, AlarmEventRecord, AlarmNotificationType, PerceivedSeverity, DateRange, NotifyFileReady, ProbableCause, and AlarmDefinition. LogQuery (0..\*) has a dateRanges relationship with DateRange (data type) and a MayCreate relationship with NotifyFileReady (notification). AlarmSubscription creates AlarmEvent (notification). AlarmList has many AlarmEventRecords. AlarmEventRecord is associated with AlarmEvent, ResourceType, Resource, AlarmNotificationType, and PerceivedSeverity. AlarmEventRecord is diagnosed as ProbableCause and defined by AlarmDefinition in the ManagementArtifacts package. + +**Figure 4.2.1.3.1.3.1-1 O2ims Alarm Relationship View** + +###### 4.2.1.3.1.3.2 Infrastructure Performance Relationships + +The O2ims\_InfrastructureMonitoring services follow a flow described in the O2 GAP[i.2] clause 3.9.9. This primarily consists of: + +- 1) The Performance Measurement Store - used for storage and configuration of performance measurements. +- 2) The Performance Measurement Job - used to collect performance measurements and insert them into the Performance Measurement Store. +- 3) The Performance Subscription - used to identify what PerformanceMeasurementRecord(s) in the PerformanceMeasurementStore are reported, when they are reported, and how the report is to be delivered to the subscriber. +- 4) The Performance Measurement Report - The notification payload used to convey measurement values identified by a Performance Subscription to the identified subscriber in a format selected by the subscriber. + +![Diagram illustrating the Performance Monitoring Information Flow. The flow consists of four main stages: Performance Measurement Job, Performance Measurement Store, Performance Subscription, and Performance Measurement Report. The Process Flow is: Collect (Job) -> Insert (Store) -> Extract (Subscription) -> Transform (Subscription) -> Transmit (Report) -> Receive (Report). A blue box at the bottom states: 'The Performance Measurement Job collects measurements and inserts them into the Performance Measurement Store from which a Performance Subscription selects and formats into a Performance Measurement Report and delivers the report to an identified subscriber endpoint.'](e23ed687a01eaff22dd1303a95efed85_img.jpg) + +The diagram illustrates the Performance Monitoring Information Flow. It shows a sequence of steps: Collect (Performance Measurement Job), Insert (Performance Measurement Store), Extract (Performance Subscription), Transform (Performance Subscription), Transmit (Performance Measurement Report), and Receive (Performance Measurement Report). A blue box at the bottom states: "The Performance Measurement Job collects measurements and inserts them into the Performance Measurement Store from which a Performance Subscription selects and formats into a Performance Measurement Report and delivers the report to an identified subscriber endpoint." + +Diagram illustrating the Performance Monitoring Information Flow. The flow consists of four main stages: Performance Measurement Job, Performance Measurement Store, Performance Subscription, and Performance Measurement Report. The Process Flow is: Collect (Job) -> Insert (Store) -> Extract (Subscription) -> Transform (Subscription) -> Transmit (Report) -> Receive (Report). A blue box at the bottom states: 'The Performance Measurement Job collects measurements and inserts them into the Performance Measurement Store from which a Performance Subscription selects and formats into a Performance Measurement Report and delivers the report to an identified subscriber endpoint.' + +**Figure 4.2.1.3.1.3.2-1 Performance Monitoring Information Flow** + +The O2ims\_InfrastructureMonitoring information model have sub-components as follows: + +- Performance Store + - o PerformanceMeasurementStore + - o PerformanceMeasurementRecord +- Performance Jobs + - o PerformanceMeasurementJob + - o MeasuredResource + - o CollectedMeasurement + - o PerformanceMeasurementJobChangeSubscription + - o PerformanceMeasurementJobChangeNotification +- Performance Subscriptions + - o PerformanceSubscription + - o PerformanceReportingFrequency + - o PerformanceSubscriptionCriteria +- Performance Reports + - o PerformanceMeasurementReport + +- JobReport +- ResourceReport +- MeasurementValue +- NotifyFileReady +- FileInfo + +Figure 4.2.1.3.1.3.2-2 illustrates the relationships in between the PerformanceMeasurementStore and PerformanceMeasurementRecord and other information entities. + +![UML Class Diagram showing the Performance Store Relationship View. The diagram is divided into two packages: ORAN.O2ims.Inventory and ORAN:ManagementArtifacts. In ORAN.O2ims.Inventory, there is a class «InformationObjectClass» PerformanceMeasurementStore and a class «dataType» PerformanceMeasurementRecord. PerformanceMeasurementStore has a 'MayHaveMany' relationship with PerformanceMeasurementRecord (1 to *). PerformanceMeasurementRecord has three relationships: 'MeasuredObject' with Resource (1 to *), 'CollectedBy' with PerformanceMeasurementJob (1 to *), and 'IsDefinedBy' with PerformanceMeasurementDefinition (1 to *). PerformanceMeasurementDefinition is located in the ORAN:ManagementArtifacts package.](e142b941b0051cd6913e4df54f0b9357_img.jpg) + +``` + +classDiagram + package ORAN.O2ims.Inventory { + class PerformanceMeasurementStore["«InformationObjectClass»\nPerformanceMeasurementStore"] + class PerformanceMeasurementRecord["«dataType»\nPerformanceMeasurementRecord"] + class Resource + class PerformanceMeasurementJob + } + package ORAN:ManagementArtifacts { + class PerformanceMeasurementDefinition + } + PerformanceMeasurementStore "1" -- "*" PerformanceMeasurementRecord : MayHaveMany + PerformanceMeasurementRecord "*" -- "1" Resource : MeasuredObject + PerformanceMeasurementRecord "*" -- "1" PerformanceMeasurementJob : CollectedBy + PerformanceMeasurementRecord "*" -- "1" PerformanceMeasurementDefinition : IsDefinedBy + +``` + +UML Class Diagram showing the Performance Store Relationship View. The diagram is divided into two packages: ORAN.O2ims.Inventory and ORAN:ManagementArtifacts. In ORAN.O2ims.Inventory, there is a class «InformationObjectClass» PerformanceMeasurementStore and a class «dataType» PerformanceMeasurementRecord. PerformanceMeasurementStore has a 'MayHaveMany' relationship with PerformanceMeasurementRecord (1 to \*). PerformanceMeasurementRecord has three relationships: 'MeasuredObject' with Resource (1 to \*), 'CollectedBy' with PerformanceMeasurementJob (1 to \*), and 'IsDefinedBy' with PerformanceMeasurementDefinition (1 to \*). PerformanceMeasurementDefinition is located in the ORAN:ManagementArtifacts package. + +**Figure 4.2.1.3.1.3.2-2 O2ims Performance Store Relationship View** + +Figure 4.2.1.3.1.3.2-3 illustrates the relationships in between the PerformanceMeasurementJob, MeasuredResource, CollectedMeasurement, PerformanceMeasurementJobChangeSubscription and other information entities. + +![UML class diagram showing the relationships between Performance Measurement Job entities in the ORAN.O2ims.Inventory namespace.](2d14511a46b674961a8454738d010808_img.jpg) + +``` + +classDiagram + class PerformanceMeasurementJobChangeSubscriptionDetailType["«enumeration»\nPerformanceMeasurementJobChangeSubscriptionDetailType"] + class PerformanceMeasurementJobChangeSubscription["«InformationObjectClass»\nPerformanceMeasurementJobChangeSubscription"] + class PerformanceMeasurementJobChangeSubscriptionType["«enumeration»\nPerformanceMeasurementJobChangeSubscriptionType"] + class PerformanceMeasurementJobChangeNotification["«Notification»\nPerformanceMeasurementJobChangeNotification"] + class MeasuredResource["«dataType»\nMeasuredResource"] + class PerformanceMeasurementRecord["«dataType»\nPerformanceMeasurementRecord"] + class Resource["Resource"] + class PerformanceMeasurementJob["«InformationObjectClass»\nPerformanceMeasurementJob"] + class PerformanceMeasurementJobState["«enumeration»\nPerformanceMeasurementJobState"] + class ResourceType["ResourceType"] + class CollectedMeasurement["«dataType»\nCollectedMeasurement"] + class PerformanceMeasurementDefinition["PerformanceMeasurementDefinition"] + + PerformanceMeasurementJobChangeSubscriptionDetailType ..> PerformanceMeasurementJobChangeSubscription + PerformanceMeasurementJobChangeSubscription "1" ..> PerformanceMeasurementJobChangeSubscriptionType + PerformanceMeasurementJobChangeSubscription "1" --> PerformanceMeasurementJobChangeNotification : Subscription_Creates_Notification + PerformanceMeasurementJobChangeSubscriptionType ..> PerformanceMeasurementJobChangeNotification + PerformanceMeasurementJobChangeNotification --> MeasuredResource + PerformanceMeasurementJobChangeNotification --> PerformanceMeasurementRecord + PerformanceMeasurementJobChangeNotification --> CollectedMeasurement + PerformanceMeasurementJobChangeNotification --> ResourceType + MeasuredResource --> Resource : resource + MeasuredResource --> PerformanceMeasurementJob : Job_Measures_Resources + PerformanceMeasurementRecord --> PerformanceMeasurementJob : CollectedBy + PerformanceMeasurementJobState ..> PerformanceMeasurementJob + PerformanceMeasurementJob --> CollectedMeasurement : Job_Collects_Measurements + PerformanceMeasurementJob --> CollectedMeasurement : Job_Measures_ResourceTypes + CollectedMeasurement --> ResourceType : identifiesDictionary + CollectedMeasurement --> PerformanceMeasurementDefinition : Measure_DefinedBy_Dictionary + +``` + +The diagram illustrates the relationships between Performance Measurement Job entities. Key elements include: + +- PerformanceMeasurementJobChangeSubscriptionDetailType** (enumeration) is associated with **PerformanceMeasurementJobChangeSubscription** (InformationObjectClass). +- PerformanceMeasurementJobChangeSubscription** (1) is associated with **PerformanceMeasurementJobChangeSubscriptionType** (enumeration). +- PerformanceMeasurementJobChangeSubscription** (1) is associated with **PerformanceMeasurementJobChangeNotification** (Notification) via the relationship **Subscription\_Creates\_Notification**. +- PerformanceMeasurementJobChangeSubscriptionType** (enumeration) is associated with **PerformanceMeasurementJobChangeNotification**. +- PerformanceMeasurementJobChangeNotification** is associated with **MeasuredResource** (dataType), **PerformanceMeasurementRecord** (dataType), **CollectedMeasurement** (dataType), and **ResourceType**. +- MeasuredResource** (dataType) is associated with **Resource** (Resource) via the relationship **resource**. +- MeasuredResource** (dataType) is associated with **PerformanceMeasurementJob** (InformationObjectClass) via the relationship **Job\_Measures\_Resources**. +- PerformanceMeasurementRecord** (dataType) is associated with **PerformanceMeasurementJob** via the relationship **CollectedBy**. +- PerformanceMeasurementJobState** (enumeration) is associated with **PerformanceMeasurementJob**. +- PerformanceMeasurementJob** (1) is associated with **CollectedMeasurement** (1) via the relationship **Job\_Collects\_Measurements**. +- PerformanceMeasurementJob** is associated with **CollectedMeasurement** via the relationship **Job\_Measures\_ResourceTypes**. +- CollectedMeasurement** is associated with **ResourceType** via the relationship **identifiesDictionary**. +- CollectedMeasurement** is associated with **PerformanceMeasurementDefinition** (PerformanceMeasurementDefinition) via the relationship **Measure\_DefinedBy\_Dictionary**. + +UML class diagram showing the relationships between Performance Measurement Job entities in the ORAN.O2ims.Inventory namespace. + +**Figure 4.2.1.3.1.3.2-3 O2ims Performance Measurement Job Relationship View** + +Figure 4.2.1.3.1.3.2-4 illustrates the relationships in between the PerformanceSubscription, PerformanceReportingFrequency, PerformanceSubscriptionCriteria and other information entities. + +![UML class diagram for ORAN.O2ims.Inventory showing relationships between PerformanceReportingFrequency, PerformanceSubscriptionCriteria, PerformanceSubscription, PerformanceMeasurementStore, SubscriptionMode, and ReportFormat.](b75e2526fc69dcdc330bea8fdef3345a_img.jpg) + +**ORAN.O2ims.Inventory** + +``` + +classDiagram + class PerformanceReportingFrequency["«dataType»\nPerformanceReportingFrequency"] + class PerformanceSubscriptionCriteria["«dataType»\nPerformanceSubscriptionCriteria"] + class PerformanceSubscription["«InformationObjectClass»\nPerformanceSubscription"] + class PerformanceMeasurementStore["«InformationObjectClass»\nPerformanceMeasurementStore"] + class SubscriptionMode + class ReportFormat + + PerformanceReportingFrequency --> PerformanceSubscriptionCriteria + PerformanceSubscriptionCriteria --> PerformanceSubscription : 0..1 MayHave + PerformanceSubscription --> PerformanceReportingFrequency + PerformanceSubscription ..> PerformanceMeasurementStore : SelectsFrom + PerformanceSubscription ..> ReportFormat : SelectsFrom + SubscriptionMode -.- PerformanceReportingFrequency + +``` + +The diagram illustrates the relationships within the ORAN.O2ims.Inventory package. It includes the following elements and relationships: + +- PerformanceReportingFrequency** (dataType) is associated with **SubscriptionMode** via a dashed line. +- PerformanceReportingFrequency** is associated with **PerformanceSubscriptionCriteria** (dataType) via a solid line with a diamond at the PerformanceReportingFrequency end. +- PerformanceSubscriptionCriteria** (dataType) is associated with **PerformanceSubscription** (InformationObjectClass) via a solid line with a diamond at the PerformanceSubscriptionCriteria end, labeled "0..1 MayHave". +- PerformanceSubscription** (InformationObjectClass) is associated with **PerformanceReportingFrequency** via a solid line with a diamond at the PerformanceSubscription end. +- PerformanceSubscription** (InformationObjectClass) is associated with **PerformanceMeasurementStore** (InformationObjectClass) via a dashed line labeled "SelectsFrom". +- PerformanceSubscription** (InformationObjectClass) is associated with **ReportFormat** via a dashed line labeled "SelectsFrom". + +UML class diagram for ORAN.O2ims.Inventory showing relationships between PerformanceReportingFrequency, PerformanceSubscriptionCriteria, PerformanceSubscription, PerformanceMeasurementStore, SubscriptionMode, and ReportFormat. + +**Figure 4.2.1.3.1.3.2-4 O2ims Performance Subscription Relationship View** + +Figure 4.2.1.3.1.3.2-5 illustrates the relationships in between the PerformanceMeasurementReport, JobReport, ResourceReport, MeasurementValue, NotifyFileReady, FileInfo and other information entities. + +![UML Relationship View diagram for O2ims Performance Report. The diagram shows classes in two packages: ORAN.O2ims.Inventory and ORAN.ManagementArtifacts. In ORAN.O2ims.Inventory, PerformanceSubscription (InformationObjectClass) has two dashed associations to PerformanceMeasurementReport (notification) and NotifyFileReady (notification), both labeled 'Subscription_Creates_Notification'. PerformanceMeasurementReport has a 'hasMany' association to JobReport (dataType) with multiplicity 1 at the top and 1..* at the bottom. JobReport has a 'hasMany' association to ResourceReport (dataType) with multiplicity 1 at the top and 1..* at the bottom, and a dashed 'IsFor' association to PerformanceMeasurementJob with multiplicity 1 at both ends. ResourceReport has a 'hasMany' association to MeasurementValue (dataType) with multiplicity 1 at the top and * at the bottom, and a 'MeasuredObject' association to Resource with multiplicity 1 at both ends. NotifyFileReady has a dashed association to FileInfo (dataType), which in turn has a dashed association to FileDataType (enumeration). In ORAN.ManagementArtifacts, PerformanceMeasurementDefinition is associated with MeasurementValue in the ORAN.O2ims.Inventory package via a solid line labeled 'measuredId'. A note box explains that 'measuredId' can be either 'performanceMeasurementName' or 'performanceMeasureId', and it 'identifies' the PerformanceMeasurementDefinition.](151de7a22267e747abab112051cee51a_img.jpg) + +``` + +classDiagram + class PerformanceSubscription["«InformationObjectClass»\nPerformanceSubscription"] + class PerformanceMeasurementReport["«notification»\nPerformanceMeasurementReport"] + class NotifyFileReady["«notification»\nNotifyFileReady"] + class JobReport["«dataType»\nJobReport"] + class ResourceReport["«dataType»\nResourceReport"] + class MeasurementValue["«dataType»\nMeasurementValue"] + class PerformanceMeasurementJob["PerformanceMeasurementJob"] + class FileInfo["«dataType»\nFileInfo"] + class FileDataType["«enumeration»\nFileDataType"] + class Resource["Resource"] + class PerformanceMeasurementDefinition["PerformanceMeasurementDefinition"] + + PerformanceSubscription -.-> PerformanceMeasurementReport : Subscription_Creates_Notification + PerformanceSubscription -.-> NotifyFileReady : Subscription_Creates_Notification + PerformanceMeasurementReport "1" -- "1..*" JobReport : hasMany + JobReport "1" -- "1..*" ResourceReport : hasMany + JobReport "1" -.-> "1" PerformanceMeasurementJob : IsFor + ResourceReport "1" -- "*" MeasurementValue : hasMany + ResourceReport "1" -- "1" Resource : MeasuredObject + NotifyFileReady -.-> FileInfo + FileInfo -.-> FileDataType + MeasurementValue -- PerformanceMeasurementDefinition : measuredId + +``` + +measuredId can be either: + - performanceMeasurementName + - performanceMeasureId. + +identifies + +UML Relationship View diagram for O2ims Performance Report. The diagram shows classes in two packages: ORAN.O2ims.Inventory and ORAN.ManagementArtifacts. In ORAN.O2ims.Inventory, PerformanceSubscription (InformationObjectClass) has two dashed associations to PerformanceMeasurementReport (notification) and NotifyFileReady (notification), both labeled 'Subscription\_Creates\_Notification'. PerformanceMeasurementReport has a 'hasMany' association to JobReport (dataType) with multiplicity 1 at the top and 1..\* at the bottom. JobReport has a 'hasMany' association to ResourceReport (dataType) with multiplicity 1 at the top and 1..\* at the bottom, and a dashed 'IsFor' association to PerformanceMeasurementJob with multiplicity 1 at both ends. ResourceReport has a 'hasMany' association to MeasurementValue (dataType) with multiplicity 1 at the top and \* at the bottom, and a 'MeasuredObject' association to Resource with multiplicity 1 at both ends. NotifyFileReady has a dashed association to FileInfo (dataType), which in turn has a dashed association to FileDataType (enumeration). In ORAN.ManagementArtifacts, PerformanceMeasurementDefinition is associated with MeasurementValue in the ORAN.O2ims.Inventory package via a solid line labeled 'measuredId'. A note box explains that 'measuredId' can be either 'performanceMeasurementName' or 'performanceMeasureId', and it 'identifies' the PerformanceMeasurementDefinition. + +**Figure 4.2.1.3.1.3.2-5 O2ims Performance Report Relationship View** + +##### 4.2.1.3.1.4 O-Cloud Networking Relationships + +###### 4.2.1.3.1.4.1 O-Cloud Networking Relationships Overview + +The O-Cloud Network provides seamless connectivity within an O-Cloud Site and facilitates external connectivity, such as transport network access, to various O-Cloud Resources. Clause 3.4.3 of the O-RAN.WG6.O2-GA&P [i.2] specification, + +outlines the fundamental concepts of the O-Cloud provisioning and defines these concepts at different layers. For instance, networking-related concepts such as O-Cloud Site Network Fabric (aka. SiteNWFabric) and O-Cloud Site Gateway (aka. SiteGW) can be defined at the hardware layer, which is related to that layers' consumable constructs, and the networking-related concepts such as O-Cloud Site Network (aka. SiteNW), O-Cloud Gateway, and O-Cloud AttachmentCircuit can be defined at the execution environment layer as described in the O-RAN.WG6.O2-GA&P [i.2] spec. Also, there can be inter-namespace relationships for instance, Networking concept related to an O-Cloud Node Cluster such as, O-Cloud Node Cluster Site Network (aka. NodeClusterSiteNW) defined in ORAN.O2ims.Clusters namespace mapped to a SiteNW object and terminated by an O-Cloud Gateway object defined in ORAN.O2ims.Inventory namespace. + +An O-Cloud AttachmentCircuit as defined in O-RAN.WG6.O2-GA&P [i.2], clause 3.4.3.5.10 has two possible associations — one with an O-Cloud Gateway and another with the SiteNW. This accommodates the two scenarios where a SiteNW connects to the transport network through an O-Cloud Gateway or where a SiteNW connects directly to the transport network. There can also be the case that SiteNWs are only used for internal connectivity within an O-Cloud Site, in which case, there is no need to associate (neither directly, nor via an O-Cloud Gateway) a SiteNW to an O-Cloud AttachmentCircuit. + +Figure 4.2.1.3.1.4-1 illustrates the O-Cloud networking-related Resource relationships between the Information Objects Classes. + +![UML class diagram showing O-Cloud networking-related Resource relationships between Information Object Classes. The diagram is divided into two packages: ORAN.O2ims.Clusters and ORAN.O2ims.Inventory. In ORAN.O2ims.Clusters, there is a class NodeClusterSiteNW and an InformationObjectClass NodeClusterSiteNW. In ORAN.O2ims.Inventory, there are several InformationObjectClasses: SiteNW, Compute, AttachmentCircuit, Gateway, SiteNWFabric, and SiteGW. Relationships include: NodeClusterSiteNW (1) mapped to SiteNW (*); NodeClusterSiteNW (*) terminated by Gateway (*); SiteNW (*) terminated by Compute (*); SiteNW (*) attached to AttachmentCircuit (*); SiteNW (*) realized by AttachmentCircuit (*); SiteNW (*) terminated by Gateway (*); Gateway (*) attached to SiteNWFabric (1); Gateway (*) realized by SiteNWFabric (1); Compute (*) connected to SiteNWFabric (*); AttachmentCircuit (*) connected to SiteNWFabric (*); SiteGW (*) connected to SiteNWFabric (*).](5f785f2d94ab0113d6fda962d269b24a_img.jpg) + +``` + +classDiagram + package ORAN.O2ims.Clusters { + class NodeClusterSiteNW + class "«InformationObjectClass» NodeClusterSiteNW" + } + package ORAN.O2ims.Inventory { + class "«InformationObjectClass» SiteNW" + class "«InformationObjectClass» Compute" + class "«InformationObjectClass» AttachmentCircuit" + class "«InformationObjectClass» Gateway" + class "«InformationObjectClass» SiteNWFabric" + class "«InformationObjectClass» SiteGW" + } + ORAN.O2ims.Clusters.NodeClusterSiteNW "1" --> "*" ORAN.O2ims.Inventory.«InformationObjectClass» SiteNW : MappedTo + ORAN.O2ims.Clusters.«InformationObjectClass» NodeClusterSiteNW "*" --> "*" ORAN.O2ims.Inventory.«InformationObjectClass» Gateway : TerminatedBy + ORAN.O2ims.Inventory.«InformationObjectClass» SiteNW "*" --> "*" ORAN.O2ims.Inventory.«InformationObjectClass» Compute : TerminatedBy + ORAN.O2ims.Inventory.«InformationObjectClass» SiteNW "*" --> "*" ORAN.O2ims.Inventory.«InformationObjectClass» AttachmentCircuit : AttachTo + ORAN.O2ims.Inventory.«InformationObjectClass» SiteNW "*" --> "*" ORAN.O2ims.Inventory.«InformationObjectClass» AttachmentCircuit : RealizedBy + ORAN.O2ims.Inventory.«InformationObjectClass» SiteNW "*" --> "*" ORAN.O2ims.Inventory.«InformationObjectClass» Gateway : TerminatedBy + ORAN.O2ims.Inventory.«InformationObjectClass» Gateway "*" --> "1" ORAN.O2ims.Inventory.«InformationObjectClass» SiteNWFabric : AttachTo + ORAN.O2ims.Inventory.«InformationObjectClass» Gateway "*" --> "1" ORAN.O2ims.Inventory.«InformationObjectClass» SiteNWFabric : RealizedBy + ORAN.O2ims.Inventory.«InformationObjectClass» Compute "*" --> "*" ORAN.O2ims.Inventory.«InformationObjectClass» SiteNWFabric : ConnectedTo + ORAN.O2ims.Inventory.«InformationObjectClass» AttachmentCircuit "*" --> "*" ORAN.O2ims.Inventory.«InformationObjectClass» SiteNWFabric : ConnectedTo + ORAN.O2ims.Inventory.«InformationObjectClass» SiteGW "*" --> "*" ORAN.O2ims.Inventory.«InformationObjectClass» SiteNWFabric : ConnectedTo + +``` + +UML class diagram showing O-Cloud networking-related Resource relationships between Information Object Classes. The diagram is divided into two packages: ORAN.O2ims.Clusters and ORAN.O2ims.Inventory. In ORAN.O2ims.Clusters, there is a class NodeClusterSiteNW and an InformationObjectClass NodeClusterSiteNW. In ORAN.O2ims.Inventory, there are several InformationObjectClasses: SiteNW, Compute, AttachmentCircuit, Gateway, SiteNWFabric, and SiteGW. Relationships include: NodeClusterSiteNW (1) mapped to SiteNW (\*); NodeClusterSiteNW (\*) terminated by Gateway (\*); SiteNW (\*) terminated by Compute (\*); SiteNW (\*) attached to AttachmentCircuit (\*); SiteNW (\*) realized by AttachmentCircuit (\*); SiteNW (\*) terminated by Gateway (\*); Gateway (\*) attached to SiteNWFabric (1); Gateway (\*) realized by SiteNWFabric (1); Compute (\*) connected to SiteNWFabric (\*); AttachmentCircuit (\*) connected to SiteNWFabric (\*); SiteGW (\*) connected to SiteNWFabric (\*). + +**Figure 4.2.1.3.1.4.1-1 illustrates the O-Cloud networking-related Resource relationships between the Information Object Classes.** + +###### 4.2.1.3.1.4.2 O-Cloud Networking Relationships View + +###### 4.2.1.3.1.4.2.1 Overview + +The O-RAN.WG6.O2-GA&P [i.2], clause 3.4.3.3 outlines fundamental concepts of the Resource View. For enabling separation of authority and operations, O-Cloud offers various types of resource views, in the form of different group of actors, some of them deals with hardware or more physical types of O-Cloud Resources whereas, others consume logical set of O-Cloud Resources. + +###### 4.2.1.3.1.4.2.2 Hardware Layer View + +The O-RAN.WG6.O2-GA&P [i.2], clause 3.4.3.4 explains the Hardware Layer concept, which forms the foundation of a cloud, comprising physical computes that are inter-connected through network fabric and routers for external + +connectivity. According to O-RAN.WG6.CADS [i.3], a Cloud Site hosts Cloud Infrastructure equipment, abstracting O-Cloud Resources for leasing through the IMS. From the SMO perspective, understanding hardware concepts focuses on O-Cloud Resource locations, capabilities, capacity, availability, and potential disturbances, rather than physical realization. + +![Diagram of the Hardware Layer View showing Information Object Classes and their connections.](f8ba41cd734ca6784393b8f3692e01aa_img.jpg) + +The diagram, titled "ORAN.O2ims.Inventory", illustrates the "Hardware Layer" view. It contains three Information Object Classes (IOCs) represented as yellow boxes with red borders: + +- «InformationObjectClass» Compute** +- «InformationObjectClass» SiteGW** +- «InformationObjectClass» SiteNWFabric** + +Connections between these IOCs are shown with red arrows: + +- A red arrow labeled "ConnectedTo" points from **«InformationObjectClass» Compute** to **«InformationObjectClass» SiteNWFabric**. Both ends of the arrow are marked with an asterisk (\*). +- A red arrow labeled "ConnectedTo" points from **«InformationObjectClass» SiteGW** to **«InformationObjectClass» SiteNWFabric**. Both ends of the arrow are marked with an asterisk (\*). + +Diagram of the Hardware Layer View showing Information Object Classes and their connections. + +**Figure 4.2.1.3.1.4.2.2-1 illustrates the Hardware Layer View and networking related Information Object Classes** + +###### 4.2.1.3.1.4.2.3 Execution Environment Layer View + +The O-RAN.WG6.O2-GA&P [i.2], clause 3.4.3.5 explains the Execution Environment Layer concept, which transforms hardware layer constructs into consumable O-Cloud Node(s), Site Network(s), Gateway(s), and many more, as abstract O-Cloud Resources available for leasing through the IMS. + +![Diagram of the Execution Environment Layer View showing relationships between SiteNW, Gateway, and AttachmentCircuit classes.](73b30087c36e683b511e2d5aa4cd5a55_img.jpg) + +**ORAN.O2ims.Inventory** + +``` + +classDiagram + class SiteNW["«InformationObjectClass» SiteNW"] + class Gateway["«InformationObjectClass» Gateway"] + class AttachmentCircuit["«InformationObjectClass» AttachmentCircuit"] + SiteNW "*" --> "*" Gateway : TerminatedBy + SiteNW "1" --> "*" AttachmentCircuit : AttachTo + Gateway "1" --> "*" AttachmentCircuit : AttachTo + +``` + +The diagram illustrates the Execution Environment Layer View within the ORAN.O2ims.Inventory namespace. It shows three classes: «InformationObjectClass» SiteNW, «InformationObjectClass» Gateway, and «InformationObjectClass» AttachmentCircuit. The relationships are as follows: SiteNW has a many-to-many relationship with Gateway (TerminatedBy), SiteNW has a one-to-many relationship with AttachmentCircuit (AttachTo), and Gateway has a one-to-many relationship with AttachmentCircuit (AttachTo). + +Diagram of the Execution Environment Layer View showing relationships between SiteNW, Gateway, and AttachmentCircuit classes. + +Figure 4.2.1.3.1.4.2.3-1 illustrates the Execution Environment Layer View and networking related Information Object Classes + +#### 4.2.1.3.2 Inheritance + +##### 4.2.1.3.2.1 O2ims Inventory Inheritance + +This subclause depicts the inheritance relationships of inventory object classes. + +This subclause depicts the inheritance relationships. + +![Diagram showing the inheritance relationships of inventory object classes.](9f2241cf65acf8f26e299937b95a7d0d_img.jpg) + +``` + +classDiagram + class Top["«InformationObjectClass» Top"] + class InventorySubscription["«InformationObjectClass» InventorySubscription"] + class ResourceType["«InformationObjectClass» ResourceType"] + class InfrastructureInventoryObject["«InformationObjectClass» InfrastructureInventoryObject"] + class DeploymentManager["«InformationObjectClass» DeploymentManager"] + class Resource["«InformationObjectClass» Resource"] + class ResourcePool["«InformationObjectClass» ResourcePool"] + class Location["«InformationObjectClass» Location"] + class OCloud["«InformationObjectClass» O-Cloud"] + class OCloudSite["«InformationObjectClass» O-CloudSite"] + + Top <|-- InventorySubscription + Top <|-- InfrastructureInventoryObject + InfrastructureInventoryObject <|-- ResourceType + InfrastructureInventoryObject <|-- DeploymentManager + InfrastructureInventoryObject <|-- Resource + InfrastructureInventoryObject <|-- ResourcePool + InfrastructureInventoryObject <|-- Location + InfrastructureInventoryObject <|-- OCloud + InfrastructureInventoryObject <|-- OCloudSite + +``` + +The diagram illustrates the inheritance relationships of inventory object classes. At the top is «InformationObjectClass» Top. Below it is «InformationObjectClass» InventorySubscription, which inherits from Top. Below Top is «InformationObjectClass» InfrastructureInventoryObject, which inherits from Top. Below InfrastructureInventoryObject are five classes: «InformationObjectClass» ResourceType, «InformationObjectClass» DeploymentManager, «InformationObjectClass» Resource, «InformationObjectClass» ResourcePool, «InformationObjectClass» Location, «InformationObjectClass» O-Cloud, and «InformationObjectClass» O-CloudSite. All these five classes inherit from InfrastructureInventoryObject. + +Diagram showing the inheritance relationships of inventory object classes. + +Figure 4.2.1.3.2.1-1 O2ims Inventory Intra-Namespaces Inheritance + +![Figure 4.2.1.3.2.1-2 O2ims Inventory Inter-Namespace Inheritance diagram](4df41130fff6f8a61a447cd22dbac6d6_img.jpg) + +This diagram illustrates the inheritance relationships for the O2ims Inventory across different namespaces. It shows three main namespaces: ORAN.O2ims.Artifacts, ORAN.O2ims.Infrastructure, and ORAN.O2ims.Cluster. The ORAN.O2ims.Inventory namespace is central, containing the «InformationObjectClass» InfrastructureInventoryObject. Inheritance is shown with red arrows pointing from the parent namespaces to the child namespace. Specifically, «InformationObjectClass» ArtifactResourceType and «InformationObjectClass» ArtifactResource from ORAN.O2ims.Artifacts inherit from «InformationObjectClass» InfrastructureInventoryObject. Similarly, «InformationObjectClass» InfrastructureResourceType and «InformationObjectClass» InfrastructureResource from ORAN.O2ims.Infrastructure inherit from «InformationObjectClass» InfrastructureInventoryObject. The ORAN.O2ims.Cluster namespace contains four classes: «InformationObjectClass» NodeClusterType, «InformationObjectClass» NodeCluster, «InformationObjectClass» ClusterResource, and «InformationObjectClass» ClusterResourceType, all of which inherit from «InformationObjectClass» InfrastructureInventoryObject. + +Figure 4.2.1.3.2.1-2 O2ims Inventory Inter-Namespace Inheritance diagram + +Figure 4.2.1.3.2.1-2 O2ims Inventory Inter-Namespace Inheritance + +##### 4.2.1.3.2.2 Infrastructure Monitoring Inheritance + +This subclause depicts the inheritance relationships of alarm and performance. + +![Figure 4.2.1.3.2.2-1 O2ims Alarm Inheritance diagram](1c82cd7cc9b8b8b3272bc7bbf4fd4135_img.jpg) + +This diagram shows the inheritance relationships for alarm monitoring. It features a central «InformationObjectClass» Top node. Three other nodes, AlarmList, AlarmSubscription, and LogQuery, all inherit from Top, as indicated by red arrows pointing from each of these nodes to the Top node. + +Figure 4.2.1.3.2.2-1 O2ims Alarm Inheritance diagram + +Figure 4.2.1.3.2.2-1 O2ims Alarm Inheritance + +Figure 4.2.1.3.2.2-2 depicts the inheritance relationships of Performance. + +![Figure 4.2.1.3.2.2-2 O2ims Performance Inheritance diagram](80df01979f7b2317571d8dd77a170cc0_img.jpg) + +This diagram illustrates the inheritance relationships for performance monitoring. It shows a central «InformationObjectClass» Top node. Four other nodes inherit from Top: PerformanceMeasurementJobChangeSubscription (top), PerformanceMeasurementJob (left), PerformanceMeasurementStore (right), and PerformanceSubscription (bottom). Red arrows point from each of these four nodes to the central Top node. + +Figure 4.2.1.3.2.2-2 O2ims Performance Inheritance diagram + +Figure 4.2.1.3.2.2-1 O2ims Performance Inheritance + +#### 4.2.1.4 Class Definitions + +##### 4.2.1.4.1 OCloud + +###### 4.2.1.4.1.1 Definition + +The OCloud represents an instance of an O-Cloud. For more information about O-Cloud, refer to the "O-RAN O2 General Aspects and Principles Specification", clause 3.1 [i.2]. + +###### 4.2.1.4.1.2 Attributes + +**Table 4.2.1.4.1.2-1 Attributes Properties for OCloud** + +| Attribute name | Data Type/Description | Properties | +|------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| oCloudId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the O-Cloud instance. Internally generated within an O-Cloud instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| globalCloudId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the O-Cloud instance assigned by the SMO. This identifier is globally unique across O-Cloud instances known to the SMO. This value was provided by the SMO at cloud genesis and is stored in the O-Cloud IMS Inventory. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable name of the O-Cloud as identified by the SMO at cloud genesis. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable description of the O-Cloud as provided by the SMO at cloud genesis. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| infrastructureManagementServicesEndpoint | <b>Data Type:</b> string<br><br><b>Description:</b> The URI root to all services provided by the O2ims interface. Inventory is one of these services. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | + +| Attribute name | Data Type/Description | Properties | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| resourceTypes | <b>Data Type:</b> array<br><br><b>Description:</b> List of Resource types. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True<br>items: ResourceTyp<br>e | +| oCloudSites | <b>Data Type:</b> array<br><br><b>Description:</b> List of O-Cloud Sites that are known by the IMS and need to be exposed to the SMO for Homing. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: True<br>minItems: 1<br>uniqueItems: True<br>items: OCloudSite | +| deploymentManagers | <b>Data Type:</b> array<br><br><b>Description:</b> List of Deployment managers. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True<br>items: DeploymentM<br>anager | +| smoRegistrationService | <b>Data Type:</b> string<br><br><b>Description:</b> IP address endpoint or the URL of the SMO. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uri | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by the vendor to extend the information provided about the O-Cloud. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: AttributeVa<br>luePair | + +4.2.1.4.1.3 Attribute constraints + +None. + +4.2.1.4.1.4 State diagram + +None. + +##### 4.2.1.4.2 ResourceType + +###### 4.2.1.4.2.1 Definition + +The ResourceType represents a resource type in an O-Cloud. + +Resource types provide the categorization of O-Cloud Nodes as described in the O-RAN Cloud Architecture and Deployment Scenarios [i.3] specification. The values for these types are used to build the inventory and enable an authorized consumer to track resource changes over time. The O-Cloud provides a mechanism to discover the resource types with respective operations on resource types. + +###### 4.2.1.4.2.2 Attributes + +**Table 4.2.1.4.2.2-1 Attributes Properties for ResourceType** + +| Attribute name | Data Type/Description | Properties | +|-------------------|----------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| resourceTypeId | <b>Data Type:</b> string<br><b>Description:</b> Identifier of the resource type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><b>Description:</b> Name of the resource type as identified by the cloud provider. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><b>Description:</b> Human readable description of the resource type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| vendor | <b>Data Type:</b> string<br><b>Description:</b> Name of the provider of the resource type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| model | <b>Data Type:</b> string<br><b>Description:</b> Information about the model of the resource type | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| version | <b>Data Type:</b> string<br><b>Description:</b> Version or generation of the resource type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| alarmDictionaryId | <b>Data Type:</b> string<br><b>Description:</b> Identifier of the associated dictionary of alarms | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False | + +| Attribute name | Data Type/Description | Properties | +|-------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | that can be generated by the resource type. If no alarms are reported against a resource of this resourceType then the alarmDictionaryId is set to null. | nullable: True<br>format: uuid | +| performanceDictionaryId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the associated dictionary of performance measurements that can be collected for the resource type. If the resource of this resourceType does not provide any measurements then the performanceDictionaryId is set to null. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>format: uuid | +| resourceKind | <b>Data Type:</b> string<br><br><b>Description:</b> A value describing the "physicality" of the resource type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>enum:<br>- UNDEFINED<br>- PHYSICAL<br>- LOGICAL | +| resourceClass | <b>Data Type:</b> string<br><br><b>Description:</b> A value describing the functional role within the cloud for the resource type.<br><br>The list of resource classes is not exhaustive, additional classes will be assessed on a case by case basis. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>enum:<br>- UNDEFINED<br>- COMPUTE<br>- NETWORKING<br>- STORAGE | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by the vendor to extend the information provided about the Resource Type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | + +###### 4.2.1.4.2.3 Attribute constraints + +None. + +###### 4.2.1.4.2.4 State diagram + +None. + +##### 4.2.1.4.3 ResourcePool + +###### 4.2.1.4.3.1 Definition + +The ResourcePool represents a resource pool instance in an O-Cloud. + +The O-Cloud is a distributed cloud with resources placed in different locations. Those resources are organized into resource pools. There can be more than one resource pool for a given O-Cloud at the same physical location. However, each resource pool requires a different identity since the SMO will direct a deployment based on homing policies to a specific location. This is different than typical cloud deployments as location is key to meeting latency requirements, sometime to elements outside of the O-Cloud. + +NOTE 1: The identity of a resource pool cannot be tied to a specific resource within the pool as that resource may be replaced as part of the O-Cloud lifecycle. + +NOTE 2: The resource pool is described in the Cloud Architecture and Deployment Scenarios Technical Report [i.3] but may not be needed for exposure through the Information Model and subsequent O2 IMS interface. + +###### 4.2.1.4.3.2 Attributes + +**Table 4.2.1.4.3.2-1 Attributes Properties for ResourcePool** + +| Attribute name | Data Type/Description | Properties | +|----------------|----------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| resourcePoolId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the resource pool. Locally unique within the scope of an O-Cloud instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable name of the resource pool. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| oCloudSiteId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the O-Cloud site the resource pool is a part of. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable description of the resource pool. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | + +| Attribute name | Data Type/Description | Properties | +|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| resources | <b>Data Type:</b> array<br><br><b>Description:</b> List of resource IDs that are part of the resource pool. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True<br>items: string | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by the vendor to extend the information provided about the Resource Pool. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | + +###### 4.2.1.4.3.3 Attribute constraints + +None. + +###### 4.2.1.4.3.4 State diagram + +None. + +##### 4.2.1.4.4 Resource + +###### 4.2.1.4.4.1 Definition + +The Resource represents an instance of a resource in the O-Cloud. + +Resource pools are comprised of resources, wherein a specific instance of a resource can only be part of a single resource pool. + +Resources are of a specific resource type. The resource type of a given resource instance does not change over the lifetime of such a resource instance. + +The Resource is a Specialized Object that derives from a Generalized Object, the InfrastructureInventoryObject. The Resource inherits the attributes from the InfrastructureInventoryObject. + +###### 4.2.1.4.4.2 Attributes + +**Table 4.2.1.4.4.2-1 Attributes Properties for Resource** + +| Attribute name | Data Type/Description | Properties | +|----------------|--------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| resourceId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the resource. Locally unique within the scope of an O- | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Cloud instance. | format: uuid | +| description | <b>Data Type:</b> string<br><b>Description:</b> Human readable description of the resource. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| resourceTypeId | <b>Data Type:</b> string<br><b>Description:</b> Reference to the resource type of the resource. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| globalAssetId | <b>Data Type:</b> string<br><b>Description:</b> Identifier or serial number of the resource, if available. It is required only if the resource has been identified during its addition to the cloud as a reportable asset in the SMO inventory. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| resourcePoolId | <b>Data Type:</b> string<br><b>Description:</b> Reference to the resource pool that the resource is part of. | support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| elements | <b>Data Type:</b> array<br><b>Description:</b> The resource might be composed of smaller resources or other resource instances of a different type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: Resource | +| tags | <b>Data Type:</b> array<br><b>Description:</b> Keywords describing or classifying the resource instance. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: string | +| groups | <b>Data Type:</b> array<br><b>Description:</b> Keywords denoting groups a resource belongs to. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True | + +| Attribute name | Data Type/Description | Properties | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | items: string | +| extensions | <b>Data Type:</b> array<br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by the vendor to extend the information provided about the Resource. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br>AttributeValuePair | + +###### 4.2.1.4.4.3 Attribute constraints + +None. + +###### 4.2.1.4.4.4 State diagram + +None. + +##### 4.2.1.4.5 DeploymentManager + +##### 4.2.1.4.5.1 Definition + +The DeploymentManager represents an instance of a DMS in the O-Cloud. This class allows a client to discover the details about a DMS instance. This class provides a list of supported capabilities, and metrics for total capacity, current allocations, current reservations. For more information about DMS, refer to "O-RAN O2 General Aspects and Principles Specification, clause 1.3.1 "[i2]. + +The available capacity information supported by a DeploymentManager shall be calculated as Capacity - Allocated - Reserved. + +###### 4.2.1.4.5.2 Attributes + +**Table 4.2.1.4.5.2-1 Attributes Properties for DeploymentManager** + +| Attribute name | Data Type/Description | Properties | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| deploymentManagerId | <b>Data Type:</b> string<br><b>Description:</b> Identifier of the deployment manager. Locally unique within the scope of an O-Cloud instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><b>Description:</b> Human readable name of the deployment manager as identified by the cloud provider. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | + +| Attribute name | Data Type/Description | Properties | +|-------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable description of the deployment manageras populated by the cloud provider. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| oCloudId | <b>Data Type:</b> string<br><br><b>Description:</b> Reference to the O-Cloud associated to the deployment manager. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| deploymentManagementServiceEndpoint | <b>Data Type:</b> string<br><br><b>Description:</b> Endpoint to access the management services of the deployment manager. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uri | +| supportedLocations | <b>Data Type:</b> array<br><br><b>Description:</b> List of globalLocationIDs that were assigned to resource pools that resources allocated to the service instance belong to. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True<br>items: string | +| capabilities | <b>Data Type:</b> array<br><br><b>Description:</b> Information about the capabilities supported by this set of deployment management services based on the resources allocated to the service instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | +| capacity | <b>Data Type:</b> array<br><br><b>Description:</b> Information about the available, allocated and reserved O-Cloud resources capacity allocated to the deployment manager. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | +| extensions | <b>Data Type:</b> array | x-support-qualifier: M<br>readOnly: True | + +| Attribute name | Data Type/Description | Properties | +|----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by the vendor to extend the information provided about the Resource Type. | x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br>AttributeVa<br>luePair | + +##### 4.2.1.4.5.3 Attribute constraints + +None. + +###### 4.2.1.4.5.4 State diagram + +None. + +##### 4.2.1.4.6 InventorySubscription + +###### 4.3.1.4.6.1 Definition + +The InventorySubscription represents an instance of a subscription to infrastructure inventory notifications for when an *InfrastructureInventoryObject\_* within the inventory changes. + +Subscriptions are required for a notification to be generated. Information about the change is provided to the consumer when the consumers specified criteria is met. The absence of a filter means all events are sent. + +##### 4.2.1.4.6.2 Attributes + +**Table 4.2.1.4.6.2-1 Attributes Properties for InventorySubscription** + +| Attribute name | Data Type/Description | Properties | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| subscriptionId | <b>Data Type:</b> string<br><b>Description:</b> Identifier of the subscription. Locally unique within the scope of an O-Cloud instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| callback | <b>Data Type:</b> string<br><b>Description:</b> The URL of the callback to which notifications are delivered to. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uri | +| consumerSubscriptionId | <b>Data Type:</b> string<br><b>Description:</b> The consumer may provide its identifier for tracking, routing, or identifying the subscription | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>format: uuid | + +| Attribute name | Data Type/Description | Properties | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------| +| | used to report the event. | | +| filter | <b>Data Type:</b> string<br><br><b>Description:</b> Criteria for events which do not need to be reported or will be filtered by the subscription notification service. Therefore, if a filter is not provided then all events are reported. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | + +###### 4.2.1.4.6.3 Attribute constraints + +None. + +###### 4.2.1.4.6.4 State diagram + +None. + +##### 4.2.1.4.7 *InfrastructureInventoryObject\_* + +##### 4.2.1.4.7.1 Definition + +The *InfrastructureInventoryObject\_* is an abstract class which shall be implemented by one of its specific sub-classes. The *InfrastructureInventoryObject\_* does not have any common attributes. + +The *InfrastructureInventoryObject\_* is a Generalized Object for which specializations of this class, Specialized Object classes, can be included in a change notification. + +###### 4.2.1.4.7.2 Attributes + +This class does not provide any attributes. + +###### 4.2.1.4.7.3 Attribute constraints + +None. + +###### 4.2.1.4.7.4 State diagram + +None. + +#### 4.2.1.4.8 *InfrastructureInventoryEvent* <<notification>> + +##### 4.2.1.4.8.1 Definition + +The *InfrastructureInventoryEvent* is sent to consumers with an accepted subscription request and a filter criterion matching the content of the *InfrastructureInventoryEvent* attributes. This event can be triggered by + +change to an attribute in any subclass of the *InfrastructureInventoryObject\_* in which the property for x-inventoryNotification: or x-stateChangeNotification is “True”. + +NOTE: It is up to the protocol and data model specification to determine the one or various protocol operations enabling the notification service to invoke the specified callback procedure. + +**Table 4.2.1.4.8.1-1 InfrastructureInventoryEvent Requirements** + +| Referenced Specification | Requirement | Comment | +|------------------------------|---------------|-------------------------------| +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-GEN13 | <i>Optional clarification</i> | +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-O2-08 | | + +The information representing InfrastructureInventoryEvent shall follow the provisions indicated in table 4.2.1.4.8.2-1. + +###### 4.2.1.4.8.2 Attributes + +**Table 4.2.1.4.8.2-1 Attributes Properties for InfrastructureInventoryEvent** + +| Attribute name | Data Type/Description | Properties | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| consumerSubscriptionId | <b>Data Type:</b> string<br><br><b>Description:</b> The consumer may provide its identifier for tracking, routing, or identifying the subscription used to report the event. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| notificationEventType | <b>Data Type:</b> string<br><br><b>Description:</b> The type (CREATE, MODIFY, DELETE) of event being reported | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: enum<br>enum:<br>- CREATE<br>- MODIFY<br>- DELETE | +| objectRef | <b>Data Type:</b> string<br><br><b>Description:</b> The resultant reference to the object on which the action occurred. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>format: url | +| priorObjectState | <b>Data Type:</b> InfrastructureInventoryObject<br><br><b>Description:</b> If the Event type is 'MODIFY' or 'DELETE' this field will be populated with a copy of the object | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | + +| Attribute name | Data Type/Description | Properties | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| | prior to the event. | | +| postObjectState | <b>Data Type:</b><br>InfrastructureInventoryObject<br><br><b>Description:</b> If the Event type is 'CREATE' or 'MODIFY' this field will be populated with a copy of the object after the event. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | + +###### 4.2.1.4.8.3 Attribute constraints + +None. + +##### 4.2.1.4.8.4 State diagram + +None. + +#### 4.2.1.4.9 OCloudAvailableNotification <<notification>> + +##### 4.2.1.4.9.1 Definition + +Although the Genesis lifecycle event precedes the existence of the O2ims in the O-Cloud there is a minimal set of data expected to be provided from the SMO to the process. This information is retained in the O-Cloud and is used to register the O-Cloud with the SMO once it becomes usable. Data expected to be included with the callback URI in the genesis data is the globalCloudId, each globalLocationId, and each globalAssetId for infrastructure at those locations. Once enough of the O-Cloud is discovered, provisioned and is available for additional provisioning or workload deployments, the O-Cloud shall send the O-CloudAvailableNotification to the consumer (SMO), thus registering its InfrastructureManagementServiceEndPoint with the SMO. After receiving the notification, the SMO will interrogate the InfrastructureInventory APIs to account for corporate assets and discover the DMS service endpoints to allow workloads to be deployed. + +**NOTE:** It is up to the protocol and data model specification to determine the one or various protocol operations enabling the notification service to invoke the specified callback procedure. + +**Table 4.2.1.4.9.1-1 OCloudAvailableNotification Requirements** + +| Referenced Specification | Requirement | Comment | +|------------------------------|--------------|-------------------------------| +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-GEN5 | <i>Optional clarification</i> | + +The information representing OCloudAvailableNotification shall follow the provisions indicated in table 4.2.1.4.9.2-1. + +###### 4.2.1.4.9.2 + +###### Attributes + +**Table 4.2.1.4.9.2-1 Attributes Properties for OCloudAvailableNotification** + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| globalCloudId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the O-Cloud instance assigned by the SMO. This identifier is globally unique across O-Cloud instances known to the SMO. This value was provided by the SMO at cloud genesis and is stored in the O-Cloud IMS Inventory. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| oCloudId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the O-Cloud instance. Unique within an O-Cloud instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| IMS_EP | <b>Data Type:</b> string<br><br><b>Description:</b> URL to the resource within the O-Cloud for other attributes. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uri | + +###### 4.2.1.4.9.3 + +###### Attribute constraints + +None. + +###### 4.2.1.4.9.4 + +###### State diagram + +None. + +##### 4.2.1.4.10 AlarmEventRecord <<dataType>> + +###### 4.2.1.4.10.1 + +###### Definition + +The AlarmEventRecord represents a stored instance of an alarm detected within the O-Cloud Resources and stored by the IMS. + +The AlarmEventRecord can represent either a current active alarm or one that occurred in the past. Retention of an AlarmEventRecord is dependent on IMS configuration which would be set through an IMS Provisioning service. + +Table 4.2.1.4.10.1-1 AlarmEventRecord Requirements + +| Referenced Specification | Requirement | Comment | +|------------------------------|---------------|-------------------------------| +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-O2-17 | <i>Optional clarification</i> | +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-O2-73 | | + +###### 4.2.1.4.10.2 Attributes + +Table 4.2.1.4.10.2-1 Attributes Properties for AlarmEventRecord + +| Attribute name | Data Type/Description | Properties | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| alarmEventRecordId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of an entry in the AlarmEventRecord. Locally unique within the scope of an O-Cloud instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| resourceTypeId | <b>Data Type:</b> string<br><br><b>Description:</b> A reference to the type of resource which caused the alarm. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| resourceId | <b>Data Type:</b> string<br><br><b>Description:</b> A reference to the resource instance which caused the alarm. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| alarmDefinitionId | <b>Data Type:</b> string<br><br><b>Description:</b> A reference to the Alarm Definition record in the Alarm Dictionary associated with the referenced Resource Type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| probableCauseId | <b>Data Type:</b> string<br><br><b>Description:</b> A reference to the ProbableCause of the Alarm. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| alarmRaisedTime | <b>Data Type:</b> string<br><br><b>Description:</b> This field is populated with a Date/Time stamp value when the AlarmEventRecord is created. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: date-time | +| alarmChangedTime | <b>Data Type:</b> string | x-support-qualifier: M<br>readOnly: True | + +| Attribute name | Data Type/Description | Properties | +|----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <b>Description:</b> This field is populated with a Date/Time stamp value when any value of the AlarmEventRecord is modified. | x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: date-time | +| alarmClearedTime | <b>Data Type:</b> string<br><br><b>Description:</b> This field is populated with a Date/Time stamp value when the alarm condition is cleared. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: True<br>format: date-time | +| alarmAcknowledgeTime | <b>Data Type:</b> string<br><br><b>Description:</b> This field is populated with a Date/Time stamp value when the alarm condition is acknowledged. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: True<br>format: date-time | +| alarmAcknowledged | <b>Data Type:</b> boolean<br><br><b>Description:</b> This is a Boolean value defaulted to False. When a system acknowledges an alarm, it is then set to True. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>default: False | +| perceivedSeverity | <b>Data Type:</b> string<br><br><b>Description:</b> This is an enumerated set of values which identify the perceived severity of the alarm. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>enum: <ul style="list-style-type: none"> <li>- CRITICAL</li> <li>- MAJOR</li> <li>- MINOR</li> <li>- WARNING</li> <li>- INDETERMINATE</li> <li>- CLEARED</li> </ul> | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> Unspecified (not standardized) properties (keys) which are tailored by the vendor or operator to extend the information provided about the O-Cloud Alarm. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | + +###### 4.2.1.4.10.3 Attribute constraints + +None. + +##### 4.2.1.4.10.4 State diagram + +None. + +##### 4.2.1.4.11 AlarmEvent <<notification>> + +###### 4.2.1.4.11.1 Definition + +The AlarmEvent represents a notification of an Alarm sent by the IMS to a registered Subscriber for a fault detected within an O-Cloud Resources. + +The AlarmEvent can represent either a new alarm, a change of occurrence, or state change of an existing alarm. + +**Table 4.2.1.4.11.1-1 AlarmEvent Requirements** + +| Referenced Specification | Requirement | Comment | +|------------------------------|---------------|-------------------------------| +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-O2-16 | <i>Optional clarification</i> | + +###### 4.2.1.4.11.2 Attributes + +**Table 4.2.1.4.11.2-1 Attributes Properties for AlarmEvent** + +| Attribute name | Data Type/Description | Properties | +|------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| globalCloudId | <b>Data Type:</b> string<br><b>Description:</b> Identifier of the O-Cloud instance assigned by the SMO. This identifier is globally unique across O-Cloud instances known to the SMO. This value was provided by the SMO at cloud genesis and is stored in the O-Cloud IMS Inventory. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| consumerSubscriptionID | <b>Data Type:</b> string<br><b>Description:</b> Identifier provided by the subscriber for event to subscription traceability within the consumer realm. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| alarmNotificationType | <b>Data Type:</b> string<br><b>Description:</b> This is an enumerated set of values which identify the type of notification being sent to the subscriber. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>enum:<br>- NEW<br>- CHANGE<br>- CLEAR<br>- ACKNOWLEDGE | +| objectRef | <b>Data Type:</b> string | x-support-qualifier: M<br>readOnly: True | + +| Attribute name | Data Type/Description | Properties | +|------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <b>Description:</b> This is a URL entry to the AlarmEventRecord for this notification within the AlarmList | x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: url | +| alarmEventRecord | <b>Data Type:</b> AlarmEventRecord<br><br><b>Description:</b> This is a copy of the AlarmEventRecord associated with this event preventing the need for the alarm consumer to do a read after the notification is received. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | + +4.2.1.4.11.3 Attribute constraints + +None. + +4.2.1.4.11.4 State diagram + +None. + +4.2.1.4.12 AlarmSubscription + +4.2.1.4.12.1 Definition + +The AlarmSubscription represents a consumer wishing to be notified when specified alarm conditions occur. + +The AlarmSubscription can be filtered by criteria based on the type of notification of fields of the AlarmEventRecord. + +**Table 4.2.1.4.12.1-1 Subscription Requirements** + +| Referenced Specification | Requirement | Comment | +|------------------------------|---------------|---------| +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-02-14 | | +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-02-15 | | + +4.2.1.4.12.2 Attributes + +**Table 4.2.1.4.12.2-1 Attributes Properties for AlarmSubscription** + +| Attribute name | Data Type/Description | Properties | +|---------------------|------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| alarmSubscriptionId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the subscription. Locally unique within the scope of an O- | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | + +| Attribute name | Data Type/Description | Properties | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Cloud instance. | | +| consumerSubscriptionID | <b>Data Type:</b> string<br><b>Description:</b> The consumer may provide its identifier for tracking, routing, or identifying the subscription used to report the event if a value was provided in the SubscriptionRequest. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| filter | <b>Data Type:</b> string<br><b>Description:</b> Criteria for events which do not need to be reported or will be filtered by the subscription notification service. Therefore, if a filter is not provided then all events are reported. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>enum:<br>- NEW<br>- CHANGE<br>- CLEAR<br>- ACKNOWLEDGE | +| callback | <b>Data Type:</b> string<br><b>Description:</b> The URI of the callback to which notifications are delivered to. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: url | + +##### 4.2.1.4.12.3 Attribute constraints + +None. + +###### 4.2.1.4.12.4 State diagram + +None. + +##### 4.2.1.4.13 AlarmList + +##### 4.2.1.4.13.1 Definition + +The AlarmList represents the configuration parameters of the AlarmList and the list of AlarmEventRecords currently maintained in the O-Cloud. + +Table 4.2.1.4.13.1-1 AlarmList Requirements + +| Referenced Specification | Requirement | Comment | +|------------------------------|-----------------|---------| +| O-RAN.WG6.ORCH-USE-CASES [3] | [REQ-ORC-O2-74] | | +| O-RAN.WG6.ORCH-USE-CASES [3] | [REQ-ORC-O2-98] | | + +###### 4.2.1.4.13.2 Attributes + +Table 4.2.1.4.13.2-1 Attributes Properties for AlarmList + +| Attribute name | Data Type/Description | Properties | +|-------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| retentionPeriod | <b>Data Type:</b> integer<br><br><b>Description:</b> Specifies the number of days to retain cleared/acknowledge alarms in the AlarmList. Entries in the alarmEventRecords will be at least as long as the retentionPeriod but can be longer depending on the implementation of the purge feature. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>x-units: Days<br>minimum: 0 | +| alarmEventRecords | <b>Data Type:</b> array<br><br><b>Description:</b> The alarmEventRecords provides the storage array for AlarmEventRecords that are active or have been cleared but not purged according to the implementation of the purge feature. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: True<br>nullable: False<br>minItems: 0<br>uniqueItems: True<br>items: AlarmEventRecord | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by the vendor to extend the information provided about management of the Alarm List. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair | + +###### 4.2.1.4.13.3 Attribute constraints + +None. + +###### 4.2.1.4.13.4 State diagram + +None. + +##### 4.2.1.4.14 PerformanceMeasurementStore + +###### 4.2.1.4.14.1 Definition + +The PerformanceMeasurementStore represents the O-Cloud internal store where PerformanceMeasurementRecord(s) are retained according to the retention policy of the O-Cloud based on the configured retention period. + +The information representing the attributes of the PerformanceMeasurementStore follows the provisions indicated in table 4.2.1.4.14.2-1. + +###### 4.2.1.4.14.2 Attributes + +**Table 4.2.1.4.14.2-1 Attributes Properties for PerformanceMeasurementStore** + +| Attribute name | Data Type/Description | Properties | +|-----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| retentionPeriod | <b>Data Type:</b> integer<br><br><b>Description:</b> The number in days (24 hours) that measurements will be retained. The exact timing of when measurements are deleted are implementation dependent. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uInteger<br>x-units: days<br>minimum: 0 | +| measurements | <b>Data Type:</b> array<br><br><b>Description:</b> List of PerformanceMeasurementRecord(s) collected and stored in the performance measurement store. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 0<br>uniqueItems: True<br>items: Performance Measurement Record | + +###### 4.2.1.4.14.3 Attribute constraints + +None. + +##### 4.2.1.4.14.4 State diagram + +None. + +##### 4.2.1.4.15 PerformanceMeasurementRecord <<dataType>> + +###### 4.2.1.4.15.1 Definition + +The PerformanceMeasurementRecord represents a collected measurement in the PerformanceMeasurementStore. + +The information representing the attributes of the PerformanceMeasurementRecord follows the provisions indicated in table 4.2.1.4.15.2-1. + +##### 4.2.1.4.15.2 Attributes + +**Table 4.2.1.4.15.2-1 Attributes Properties for PerformanceMeasurementRecord** + +| Attribute name | Data Type/Description | Properties | +|------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| performanceMeasurementJobId | <b>Data Type:</b> string<br><b>Description:</b> The job identifier assigned by the O-Cloud when a performance measurement job is created. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| resourceId | <b>Data Type:</b> string<br><b>Description:</b> The resource identifier for the resource for which the collected measurement is against. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| performanceMeasurementDefinitionId | <b>Data Type:</b> string<br><b>Description:</b> The Performance Dictionary definition identifier for the collected measurement. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| timeStamp | <b>Data Type:</b> string<br><b>Description:</b> The date and time in which the measurement was collected. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: date-time | +| measurementValue | <b>Data Type:</b> Any type<br><b>Description:</b> The value of the measurement collected. The ValueType represents a variety of types depending on the measurement type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| isSuspect | <b>Data Type:</b> boolean<br><b>Description:</b> This flag is set to True if anomalous behaviour | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False | + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------|----------------| +| | was detected on the resource during the last collection interval. | nullable: True | + +###### 4.2.1.4.15.3 Attribute constraints + +None. + +##### 4.2.1.4.15.4 State diagram + +None. + +##### 4.2.1.4.16 PerformanceMeasurementJob + +##### 4.2.1.4.16.1 Definition + +The PerformanceMeasurementJob represents a process established to collect measurements and place them in the PerformanceMeasurementStore. + +The information representing the attributes of the PerformanceMeasurementJob follows the provisions indicated in table 4.2.1.4.16.2-1. + +For attributes with x-inventoryNotification: set to True or x-stateChangeNotification set to True, the notification to be sent will be the PerformanceMeasurementJobChangeNotification. + +**Table 4.2.1.4.16.1-1 PerformanceMeasurementJob Requirements** + +| Referenced Specification | Requirement | Comment | +|------------------------------|---------------|-------------------------------| +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-O2-31 | <i>Optional clarification</i> | +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-O2-32 | | + +##### 4.2.1.4.16.2 Attributes + +**Table 4.2.1.4.16.2-1 Attributes Properties for PerformanceMeasurementJob** + +| Attribute name | Data Type/Description | Properties | +|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| performanceMeasurementJobId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the performance job instance within the IMS. This value is assigned by the IMS when the job is created | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| consumerPerformanceJobId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier provided by the consumer for its purpose of managing performance jobs. This value | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | + +| Attribute name | Data Type/Description | Properties | +|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | could be the same across multiple instances of IMS performance job instances. | | +| state | <b>Data Type:</b> string<br><br><b>Description:</b> The current state of the PerformanceMeasurementJob. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False<br>enum:<br>- ACTIVE<br>- SUSPENDED<br>- DEPRECATED | +| collectionInterval | <b>Data Type:</b> integer<br><br><b>Description:</b> The interval at which performance measures will be collected and stored. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False<br>x-units: Seconds<br>minimum: 1<br>default: 300 | +| resourceScopeCriteria | <b>Data Type:</b> array<br><br><b>Description:</b> Key value pairs of resource attributes which are used to select resources from which measures are to be collected.<br><br>This criterion determines, the value set for the Qualified Resource Types. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair<br><br>example:<br>[ { "resourceTypeId", "[ "7c491f8f-7207-4c00-9b67-3d2ee8b008f0", "31040dec-8106-44db-83bc-62e1d618ea17" ]" } ] | +| measurementSelectionCriteria | <b>Data Type:</b> array<br><br><b>Description:</b> Key value pairs that identify the distinct set of measurements within the scope of a PerformanceMeasurementJob. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True<br>items: AttributeValuePair<br>example:<br>[ { "measurementGroup", "MemoryUsage", "measurementName", "cpuAverageUtilization" } ] | +| status | <b>Data Type:</b> string<br><br><b>Description:</b> The current status within the state. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False<br>enum:<br>- RUNNING<br>- FAILED<br>- DEGRADED<br>- IDLE<br>- PENDING_DELETE | + +| Attribute name | Data Type/Description | Properties | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| preinstalledJob | <b>Data Type:</b> Boolean<br><br><b>Description:</b> This is an indicator if the performance job was created for the IMS (True) or as the result of an IMS consumer request (False) | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | + +| | | | +|------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| qualifiedResourceTypes | <p><b>Data Type:</b> array</p> <p><b>Description:</b> This list is computed from evaluation of the resourceScopeCriteria. The resulting qualifiedResourceTypes are the distinct set of ResourceTypes among those measuredResources.</p> <p>This list of resource type UUIDs is used to qualify collectedMeasurements defined in the PM Dictionary of the qualified resource types.</p> | <pre> x-support-qualifier: M readOnly: True x-isInvariant: False x-inventoryNotification: False x-stateChangeNotification: False nullable: False x-isOrdered: False minItems: 0 uniqueItems: True items: uuid example: '[ "7c491f8f-7207-4c00-9b67-3d2ee8b008f0", "31040dec-8106-44db-83bc-62e1d618ea17" ]'</pre> | +| measuredResources | <p><b>Data Type:</b> array</p> <p><b>Description:</b> This is the historical list of resources measured by this job. Resources added and deleted are kept track of for the life of the job.</p> | <pre> x-support-qualifier: M readOnly: True x-isInvariant: False x-inventoryNotification: True x-stateChangeNotification: False nullable: False x-isOrdered: False minItems: 0 uniqueItems: True items: MeasuredResource</pre> | +| collectedMeasurements | <p><b>Data Type:</b> array</p> <p><b>Description:</b> The historical list of measurements that are or have been collected by this job based on its resourceScopeCriteria and measurementSelectionCriteria over the life of the job.</p> | <pre> x-support-qualifier: M readOnly: True x-isInvariant: False x-inventoryNotification: True x-stateChangeNotification: False nullable: False x-isOrdered: False minItems: 0 uniqueItems: True items: CollectedMeasurement</pre> | +| extensions | <p><b>Data Type:</b> array</p> <p><b>Description:</b> These are unspecified (not standardized) properties (key/value) which extend the information about the Performance Measurement Job.</p> | <pre> x-support-qualifier: M x-isInvariant: False x-inventoryNotification: False x-stateChangeNotification: False nullable: True x-isOrdered: False minItems: 0 uniqueItems: True items: AttributeValuePair</pre> | + +##### 4.2.1.4.16.3 + +###### Attribute constraints + +**Table 4.2.1.4.16.3-1 Attributes Constraints for PerformanceMeasurementJob** + +| Name | Definition | +|----------------------------------------|---------------------------------------------------------------------------------| +| Status is RUNNING, FAILED, or DEGRADED | Condition: Job is in the ACTIVE state. | +| Status is IDLE | Condition: Job is in the SUSPENDED state. | +| Status is PENDING_DELETE | Condition: Job is in the DEPRECATED state. | +| WriteableExtensions | Condition: preInstalledJob is False then extensions can be created and updated. | +| ReadOnlyExtensions | Condition: preInstalledJob is True then extensions, if present are read only. | + +##### 4.2.1.4.16.4 + +###### State diagram + +![State & Status Diagram for PerformanceMeasurementJob. The diagram shows three states: ACTIVE, SUSPENDED, and DEPRECATED. The initial state is a black circle leading to ACTIVE via 'Create'. ACTIVE has a note 'status in (RUNNING, FAILED, DEGRADED)'. From ACTIVE, 'Suspend' leads to SUSPENDED, and 'Resume' leads back to ACTIVE. SUSPENDED has a note 'status = IDLE' and a note 'isSuspect will be TRUE for first collected measure on Resume'. From SUSPENDED, 'Delete' leads to DEPRECATED. DEPRECATED has a note 'status = PENDING_DELETE' and a note 'Job will remain deprecated until the last performance measurement referring to it is deleted from the PM Store'. The final state is a bullseye circle.](beedc235516f64a3ef7524129003fb89_img.jpg) + +``` + +stateDiagram-v2 + [*] --> ACTIVE : Create + ACTIVE: ACTIVE +status in (RUNNING, FAILED, DEGRADED) + ACTIVE --> SUSPENDED : Suspend + SUSPENDED --> ACTIVE : Resume + SUSPENDED: SUSPENDED +status = IDLE + SUSPENDED --> DEPRECATED : Delete + DEPRECATED: DEPRECATED +status = PENDING_DELETE + DEPRECATED --> [*] + +``` + +State & Status Diagram for PerformanceMeasurementJob. The diagram shows three states: ACTIVE, SUSPENDED, and DEPRECATED. The initial state is a black circle leading to ACTIVE via 'Create'. ACTIVE has a note 'status in (RUNNING, FAILED, DEGRADED)'. From ACTIVE, 'Suspend' leads to SUSPENDED, and 'Resume' leads back to ACTIVE. SUSPENDED has a note 'status = IDLE' and a note 'isSuspect will be TRUE for first collected measure on Resume'. From SUSPENDED, 'Delete' leads to DEPRECATED. DEPRECATED has a note 'status = PENDING\_DELETE' and a note 'Job will remain deprecated until the last performance measurement referring to it is deleted from the PM Store'. The final state is a bullseye circle. + +**Figure 4.2.1.4.16.4-1 State & Status Diagram for PerformanceMeasurementJob** + +##### 4.2.1.4.17 + +##### MeasuredResource <<datatype>> + +##### 4.2.1.4.17.1 + +###### Definition + +The MeasuredResource represents a Resource that is or has been within the scope of a PerformanceMeasurementJob. + +The information representing the attributes of the MeasuredResource follows the provisions indicated in table 4.2.1.4.17.2-1. + +##### 4.2.1.4.17.2 + +###### Attributes + +**Table 4.2.1.4.17.2-1 Attributes Properties for MeasuredResource** + +| Attribute name | Data Type/Description | Properties | +|----------------|------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| resourceTypeld | <b>Data Type:</b> string<br><b>Description:</b> The resource identifier assigned by the O-Cloud when a performance measurement job is created. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| resourceId | <b>Data Type:</b> string<br><b>Description:</b> The resource | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False | + +| Attribute name | Data Type/Description | Properties | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | identifier for the resource for which the collected measurement is against. | x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| timeAdded | <b>Data Type:</b> array<br><br><b>Description:</b> List of timestamps when the resource was added to the job. All resources shall have at least one timeAdded value. It could have multiple if changes caused a deletion and subsequent reinstatement to occur. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 1<br>uniqueItems: True<br>items: date-time | +| timeDeleted | <b>Data Type:</b> array<br><br><b>Description:</b> List of timestamps when the resource was deleted from a job. Multiple values may be present if deletion occurred at different times. The effective period of the measurement would be the times between a timeAdded and timeDeleted values. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>uniqueItems: True<br>items: date-time | +| isCurrentlyMeasured | <b>Data Type:</b> boolean<br><br><b>Description:</b> Indicates if the resource is currently being measured by the contained performance job. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | + +##### 4.2.1.4.17.3 Attribute constraints + +None. + +##### 4.2.1.4.17.4 State diagram + +None. + +##### 4.2.1.4.18 CollectedMeasurement <<datatype>> + +##### 4.2.1.4.18.1 Definition + +The CollectedMeasurement represents a measurement associated with a specific ResourceType that is or has been within the scope of a PerformanceMeasurementJob. + +The information representing the attributes of the CollectedMeasurement follows the provisions indicated in table 4.2.1.4.18.2-1. + +##### 4.2.1.4.18.2 Attributes + +**Table 4.2.1.4.18.2-1 Attributes Properties for CollectedMeasurement** + +| Attribute name | Data Type/Description | Properties | +|-------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| resourceTypeIid | <b>Data Type:</b> string<br><br><b>Description:</b> The resource identifier assigned by the O-Cloud when a performance measurement job is created. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| performanceMeasurementDefinitionIid | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the measurement definition with the PM Dictionary for the specific device type identified by the resourceTypeIid. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| timeAdded | <b>Data Type:</b> array<br><br><b>Description:</b> List of timestamps when the resource was added to the job. All measurements shall have at least one timeAdded value. It could have multiple if changes caused a deletion and subsequent reinstatement to occur. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 1<br>uniqueItems: True<br>items: date-time | +| timeDeleted | <b>Data Type:</b> array<br><br><b>Description:</b> List of timestamps when the measurement was deleted from a job. Multiple values may be present if deletion occurred at different times. The effective period of the measurement would be the times between a timeAdded and timeDeleted values. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>uniqueItems: True<br>items: date-time | +| isCurrentlyMeasured | <b>Data Type:</b> boolean<br><br><b>Description:</b> Indicates if the resource is currently being measured by the contained | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | + +| Attribute name | Data Type/Description | Properties | +|----------------|-----------------------|------------| +| | performance job. | | + +4.2.1.4.18.3 Attribute constraints + +None. + +4.2.1.4.18.4 State diagram + +None. + +4.2.1.4.19 PerformanceMeasurementJobChangeSubscription + +4.2.1.4.19.1 Definition + +The PerformanceMeasurementJobChangeSubscription represents a subscription for events to be notified such as when the scope of a PerformanceMeasurementJob changes either due to an update to its criteria or a change in inventory. + +The information representing the attributes of the PerformanceJobChangeSubscription follows the provisions indicated in table 4.2.1.4.19.2-1. + +4.2.1.4.19.2 Attributes + +**Table 4.2.1.4.19.2-1 Attributes Properties for PerformanceMeasurementJobChangeSubscription** + +| Attribute name | Data Type/Description | Properties | +|-------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| performanceMeasurementJobChangeSubscriptionId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the PerformanceMeasurementJobChangeSubscription which will generate this notification. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| consumerPerformanceMeasurementJobChangeSubscriptionId | <b>Data Type:</b> string<br><br><b>Description:</b> The consumer identification value if provided on the PerformanceMeasurementJobChangeSubscription which will generate this notification. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>format: uuid | +| performanceChangesToNotify | <b>Data Type:</b> string<br><br><b>Description:</b> The enumerated set of values representing the type(s) of changes desired to be notified about (ADD, DELETE, BOTH). | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>enum:<br>- ADD<br>- DELETE<br>- BOTH | + +| Attribute name | Data Type/Description | Properties | +|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| detailsToInclude | <b>Data Type:</b> string<br><br><b>Description:</b> The enumerated set of values representing how much detail about the change to include in the notification (NONE, DELTA, COMPLETE). | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>enum:<br>- NONE<br>- DELTA<br>- COMPLETE | +| subscriptionJobFilter | <b>Data Type:</b> array<br><br><b>Description:</b> A key value set of criteria to select which jobs shall be reported on. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: True<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | +| callback | <b>Data Type:</b> string<br><br><b>Description:</b> URL to which will be able to receive the PerformanceMeasurementJobChangeNotification. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uri | + +##### 4.2.1.4.19.3 Attribute constraints + +None. + +##### 4.2.1.4.19.4 State diagram + +None. + +##### 4.2.1.4.20 PerformanceMeasurementJobChangeNotification <<notification>> + +##### 4.2.1.4.20.1 Definition + +The PerformanceMeasurementJobChangeNotification notification represents the information about a change that occurred to a PerformanceMeasurementJob due to an update to its criteria or a change in inventory for which there is a PerformanceMeasurementJobChangeSubscription established. + +The information representing the attributes of the PerformanceMeasurementJobChangeNotification follows the provisions indicated in table 4.2.1.4.20.2-1. + +**Table 4.2.1.4.20.2-1 Attributes Properties for PerformanceMeasurementJobChangeNotification** + +| Attribute name | Data Type/Description | Properties | +|-----------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| performanceMeasurementJobChangeSubscriptionId | <b>Data Type:</b> string<br><b>Description:</b> Identifier of the PerformanceMeasurementJobChangeSubscription. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| consumerPerformanceJobChangeSubscriptionId | <b>Data Type:</b> string<br><b>Description:</b> The consumer identification value if provided on the PerformanceJobChangeSubscription. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| performanceMeasurementJobId | <b>Data Type:</b> string<br><b>Description:</b> The UUID of the PerformanceMeasurementJob that incurred a change either due to a change in scope criteria or as the result of a change to O-Cloud Infrastructure Inventory. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| objectRef | <b>Data Type:</b> string<br><b>Description:</b> The URL of the service object which was modified. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uri | +| typeOfChange | <b>Data Type:</b> string<br><b>Description:</b> The enumerated set of values representing the type(s) of changes desired to be notified about (ADD, DELETE, BOTH). | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>enum:<br>- ADD<br>- DELETE<br>- BOTH | +| resourceChangeDetails | <b>Data Type:</b> array<br><b>Description:</b> If the subscription criteria indicates DELTA or COMPLETE extended information then all relevant added and/or deleted resources to the job | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>uniqueItems: True<br>x-isOrdered: True<br>items: | + +| Attribute name | Data Type/Description | Properties | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | are listed. | MeasuredResource | +| measurementChangeDetails | <b>Data Type:</b> array<br><br><b>Description:</b> If the subscription criteria indicates DELTA or COMPLETE extended information then all relevant added and/or deleted measurements of the performance measurement job are listed.. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>uniqueItems: True<br>x-isOrdered: True<br>items:<br><br>CollectedMeasurement | + +##### 4.2.1.4.20.3 Attribute constraints + +None. + +###### 4.2.1.4.20.4 State diagram + +None. + +##### 4.2.1.4.21 PerformanceSubscription + +##### 4.2.1.4.21.1 Definition + +The PerformanceSubscription represents the information required to establish the criteria by which a PerformanceMeasurementReport notification is to be generated and where to send that notification. + +**Table 4.2.1.4.21.1-1 PerformanceSubscription Requirements** + +| Referenced Specification | Requirement | Comment | +|------------------------------|---------------|------------------------| +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-O2-37 | Optional clarification | +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-O2-38 | | + +The information representing the attributes of the PerformanceSubscription follows the provisions indicated in table 4.2.1.4.21.2-1. + +###### 4.2.1.4.21.2 Attributes + +**Table 4.2.1.4.21.2-1 Attributes Properties for PerformanceSubscription** + +| Attribute name | Data Type/Description | Properties | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| performanceSubscriptionId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the performance subscription instance within the IMS. This value is assigned by the IMS | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | + +| Attribute name | Data Type/Description | Properties | +|-----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | when the subscription is created. | | +| consumerPerformanceSubscriptionId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier optionally provided by the consumer for its purpose of managing performance data. This value could be the same across multiple instances of IMS subscription instances. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| globalSubscriptionCriteria | <b>Data Type:</b> array<br><br><b>Description:</b> This is subscription criteria which will apply to each contained subscription. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>PerformanceSubscriptionCriteria | +| reportFormat | <b>Data Type:</b> string | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>enum:<br>- NOTIFICATION<br>- FILE<br>- STREAM | + +| Attribute name | Data Type/Description | Properties | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p><b>Description:</b> Enumerated set of reporting mechanism for delivery of the data identified by the PerformanceSubscription which are identified as:</p> <p>NOTIFICATION: Call the callback with the data at the specified intervals providing the data, e.g., in JSON format</p> <p>FILE: generate a file, e.g., formatted in XML to be collected and call the callback with the filename whenever one is generated.</p> <p>STREAM: Session will remain open and continue to send the data in a streaming format, e.g., Google Protocol Buffers (GPB), at the specified intervals until the session or subscription is terminated.</p> | | +| remoteFileLocation | <p><b>Data Type:</b> string</p> <p><b>Description:</b> When the reportFormat is FILE this field is populated with the URL to the remote directory where the service is expected to push the requested performance files to a remote files system. If the reportFormat is not FILE, the field is empty or not present.</p> | <p>x-support-qualifier: M</p> <p>x-isInvariant: False</p> <p>x-inventoryNotification: False</p> <p>x-stateChangeNotification: False</p> <p>nullable: True</p> <p>Format: uri</p> | +| callback | <p><b>Data Type:</b> string</p> <p><b>Description:</b> The callback to send responses for modes NOTIFICATION, or the file notification for FILE. The field</p> | <p>x-support-qualifier: M</p> <p>x-isInvariant: False</p> <p>x-inventoryNotification: False</p> <p>x-stateChangeNotification: False</p> <p>nullable: True</p> <p>Format: uri</p> | + +| Attribute name | Data Type/Description | Properties | +|---------------------------------|------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | is not required if mode is STREAM. | | +| measurementReportingFrequencies | <b>Data Type:</b> array<br><br><b>Description:</b> The frequency that specified measurements are to be reported. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True<br>items:<br><br>PerformanceReportingFrequency | + +###### 4.2.1.4.21.3 Attribute constraints + +None. + +##### 4.2.1.4.21.4 State diagram + +None. + +#### 4.2.1.4.22 PerformanceReportingFrequency <<datatype>> + +##### 4.2.1.4.22.1 Definition + +The PerformanceReportingFrequency represents the frequency that specified measurements are to be reported. + +The information representing the attributes of the PerformanceReportingFrequency follows the provisions indicated in table 4.2.1.4.22.2-1. + +##### 4.2.1.4.22.2 Attributes + +**Table 4.2.1.4.22.2-1 Attributes Properties for PerformanceReportingFrequency** + +| Attribute name | Data Type/Description | Properties | +|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| subscriptionCriteria | <b>Data Type:</b> PerformanceSubscriptionCriteria<br><br><b>Description:</b> This is subscription criteria which will apply to this subscription. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| subscriptionMode | <b>Data Type:</b> string | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>enum:<br>- TARGET_DEFINED<br>- ON_CHANGE<br>- SAMPLE | + +| Attribute name | Data Type/Description | Properties | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p><b>Description:</b> An enumerated set of values which will identify the mode in which data is reported. The valid values are as follows:</p> <p>TARGET_DEFINED:<br/>Producer of the PM data decides if ON_CHANGE or SAMPLE is more optimal.</p> <p>ON_CHANGE: Value is reported as soon as the PM Job collects it.</p> <p>SAMPLE: Value is reported at the reportInterval period.</p> | | +| reportInterval | <p><b>Data Type:</b> integer</p> <p><b>Description:</b> This is the reporting interval for the data, it is an unsigned integer representing the number of milliseconds between reports. If the reportInterval is lower than the service can provide the subscription shall return an error indicating such. If the value is set to zero (0) then the service will use its lowest supported value for the reportInterval.</p> | <pre> x-support-qualifier: M x-isInvariant: False x-inventoryNotification: False x-stateChangeNotification: False nullable: True minimum: 0 default: 0 x-units: milliseconds </pre> | +| supressRedundant | <p><b>Data Type:</b> boolean</p> <p><b>Description:</b> This flag identifying if SAMPLE values that have not changed shall (False) or shall Not (True) be transmitted.</p> | <pre> x-support-qualifier: M x-isInvariant: False x-inventoryNotification: False x-stateChangeNotification: False nullable: True default: False </pre> | +| heartbeatInterval | <p><b>Data Type:</b> integer</p> <p><b>Description:</b> When the suppressRedundant is set to (True), if heartbeatInterval is</p> | <pre> x-support-qualifier: M x-isInvariant: False x-inventoryNotification: False x-stateChangeNotification: False nullable: True minimum: 0 default: 0 </pre> | + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------| +| | a non-zero value then a duplicate value will be sent at least once per heartbeatInterval. The value shall be zero (0) or a value greater than or equal to the reportInterval. | x-units: milliseconds | + +##### 4.2.1.4.22.3 Attribute constraints + +None. + +###### 4.2.1.4.22.4 State diagram + +None. + +##### 4.2.1.4.23 PerformanceSubscriptionCriteria <<datatype>> + +##### 4.2.1.4.23.1 Definition + +The PerformanceSubscriptionCriteria represents the information required to establish which measurements for which resource shall be included in a PerformanceMeasurementReport. + +The information representing the attributes of the PerformanceSubscriptionCriteria follows the provisions indicated in table 4.2.1.4.23.2-1. + +##### 4.2.1.4.23.2 Attributes + +**Table 4.2.1.4.23.2-1 Attributes Properties for PerformanceSubscriptionCriteria** + +| Attribute name | Data Type/Description | Properties | +|----------------------|---------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| jobCriteria | <b>Data Type:</b> array<br><br><b>Description:</b> Key/Value list of criteria compared to Job data. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | +| resourceTypeCriteria | <b>Data Type:</b> array<br><br><b>Description:</b> Key/Value list of criteria compared to Resource Type data. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | +| resourceCriteria | <b>Data Type:</b> array | x-support-qualifier: M<br>x-isInvariant: False | + +| Attribute name | Data Type/Description | Properties | +|---------------------|------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <b>Description:</b> Key/Value list of criteria compared to Resource data. | x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeVa<br>luePair | +| measurementCriteria | <b>Data Type:</b> array<br><br><b>Description:</b> Key/Value list of criteria compared to Measurement Definition data. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeVa<br>luePair | + +###### 4.2.1.4.23.3 Attribute constraints + +None. + +##### 4.2.1.4.23.4 State diagram + +None. + +##### 4.2.1.4.24 PerformanceMeasurementReport <<notification>> + +##### 4.2.1.4.24.1 Definition + +The PerformanceMeasurementReport notification represents the information required to define the scope of the JobReports being sent in the notification. + +**Table 4.2.1.4.24.1-1 PerformanceMeasurementReport Requirements** + +| Referenced Specification | Requirement | Comment | +|------------------------------|---------------|-------------------------------| +| O-RAN.WG6.ORCH-USE-CASES [3] | REQ-ORC-O2-39 | <i>Optional clarification</i> | + +The information representing the attributes of the PerformanceMeasurementReport follows the provisions indicated in table 4.2.1.4.24.2-1. + +##### 4.2.1.4.24.2 Attributes + +**Table 4.2.1.4.24.2-1 Attributes Properties for PerformanceMeasurementReport** + +| Attribute name | Data Type/Description | Properties | +|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| globalCloudId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the O-Cloud instance assigned by the SMO. This identifier is globally unique across O- | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | + +| Attribute name | Data Type/Description | Properties | +|-----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Cloud instances known to the SMO. This value was provided by the SMO at cloud genesis and is stored in the O-Cloud IMS Inventory. | | +| notificationTime | <b>Data Type:</b> string<br><br><b>Description:</b> The date and time that the notification was sent. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: date-time | +| performanceSubscriptionId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the performance subscription instance within the IMS. This value is assigned by the IMS when the job is created. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| consumerPerformanceSubscriptionId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier optionally provided by the consumer for its purpose of managing performance data. This value could be the same across multiple instances of IMS subscription instances. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| jobReports | <b>Data Type:</b> array<br><br><b>Description:</b> The list of performance reports by jobId. A single subscription can subscribe to measurements collected by multiple jobs. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True<br>items: JobReport | + +4.2.1.4.24.3 Attribute constraints + +None. + +4.2.1.4.24.4 State diagram + +None. + +##### 4.2.1.4.25 JobReport <<datatype>> + +###### 4.2.1.4.25.1 Definition + +The JobReport provides the list of performance reports generated from corresponding PerformanceMeasurementJobs. A single subscription can be used to subscribe to measurements collected by multiple PerformanceManagementJobs. The data from the PerformanceMeasurementJobs are aggregated into a single report per PerformanceSubscription. + +The information representing the attributes of the JobReport follows the provisions indicated in table 4.2.1.4.25.2-1. + +###### 4.2.1.4.25.2 Attributes + +**Table 4.2.1.4.25.2-1 Attributes Properties for JobReport** + +| Attribute name | Data Type/Description | Properties | +|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| performanceJobId | <b>Data Type:</b> string<br><br><b>Description:</b> The UUID of the PerformanceMeasurementJob from which collected measurements are reported. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| consumerJobId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier provided by the consumer for its purpose of managing performance jobs. This value could be the same across multiple instances of IMS performance job instances. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| measuredResources | <b>Data Type:</b> array<br><br><b>Description:</b> The list of collected measurements for each Resource within the scope of the subscription to be included in this PerformanceMeasurementReport. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 1<br>items: ResourceReport | + +###### 4.2.1.4.25.3 Attribute constraints + +None. + +###### 4.2.1.4.25.4 State diagram + +None. + +##### 4.2.1.4.26 ResourceReport <<datatype>> + +##### 4.2.1.4.26.1 Definition + +The ResourceReport dataType represents the information required to identify the resource for which a set of measurements are being reported in the notification. + +The information representing the attributes of the ResourceReport follows the provisions indicated in table 4.2.1.4.26.2-1. + +##### 4.2.1.4.26.2 Attributes + +**Table 4.2.1.4.26.2-1 Attributes Properties for ResourceReport** + +| Attribute name | Data Type/Description | Properties | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| resourceId | <b>Data Type:</b> string<br><br><b>Description:</b> The UUID of the Resource as specified in Infrastructure Inventory. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| measurementValues | <b>Data Type:</b> array<br><br><b>Description:</b> The list of collected measurements for the Resource within the subscription included in this PerformanceMeasurementReport. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 1<br>uniqueItems: True<br>items: MeasurementValue | + +###### 4.2.1.4.26.3 Attribute constraints + +None. + +##### 4.2.1.4.26.4 State diagram + +None. + +##### 4.2.1.4.27 MeasurementValue <<datatype>> + +##### 4.2.1.4.27.1 Definition + +The MeasurementValue dataType represents the information about a collected measurement and its value to be included in a notification. + +The information representing the attributes of the MeasurementValue follows the provisions indicated in table 4.2.1.4.27.2-1. + +**Table 4.2.1.4.27.2-1 Attributes Properties for MeasurementValue** + +| Attribute name | Data Type/Description | Properties | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| performanceMeasurementId | <b>Data Type:</b> string<br><br><b>Description:</b> Based on encoding this value can be either a string consisting of the performanceMeasureName of the MeasurementDefinition in the Performance Dictionary for the Resource Type or an unsigned integer consisting of the performanceMeasurementId of the MeasurementDefinition. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| measurementCollectionTime | <b>Data Type:</b> string<br><br><b>Description:</b> If present, this is the value that is added to the PerformanceMeasurementStore. When omitted then the notificationTime is assumed to the time the value was added to the PerformanceMeasurementStore as would be the case if the subscriptionMode equated to ON_CHANGE. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>format: date-time | +| measurementValue | <b>Data Type:</b> Any type<br><br><b>Description:</b> This is the actual value of the measurement which varies in type from measurement to measurement. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| isSuspect | <b>Data Type:</b> boolean<br><br><b>Description:</b> This flag is set to True if anomalous behavior was detected on the resource between this measurement value and a prior measurement value. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>default: False | + +##### 4.2.1.4.27.3 Attribute constraints + +None. + +##### 4.2.1.4.27.4 State diagram + +None. + +##### 4.2.1.4.28 NotifyFileReady <<notification>> + +##### 4.2.1.4.28.1 Definition + +The NotifyFileReady notification represents the information about one (1) or more files to be made available to a subscriber when the reportFormat of a PerformanceSubscription is FILE or a LogQuery when a callback is supplied. This notification only makes the consumer aware of the file and does not predicate delivery of the file (push or pull). + +The information representing the attributes of the NotifyFileReady follows the provisions indicated in table 4.2.1.4.28.2-1. + +##### 4.2.1.4.28.2 Attributes + +**Table 4.2.1.4.28.2-1 Attributes Properties for NotifyFileReady** + +| Attribute name | Data Type/Description | Properties | +|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| globalCloudId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the O-Cloud instance assigned by the SMO. This identifier is globally unique across O-Cloud instances known to the SMO. This value was provided by the SMO at cloud genesis and is stored in the O-Cloud IMS Inventory. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| subscriptionId | <b>Data Type:</b> string<br><br><b>Description:</b> When the notification is created due to a PerformanceSubscription this attribute will contain the identifier of the performanceSubscriptionId for this notification. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>format: uuid | +| consumerSubscriptionId | <b>Data Type:</b> string<br><br><b>Description:</b> When the notification is created due to a PerformanceSubscription | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | + +| Attribute name | Data Type/Description | Properties | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>this attribute will contain the identifier provided by the consumer for its purpose of managing performance data and may be included in the PerformanceSubscription.</p> <p>If the notification is due to a logQuery request this attribute shall provide the consumerLogRequestId when provided on the request to allow the consumer to correlate it to the original request.</p> | | +| eventTime | <p><b>Data Type:</b> string</p> <p><b>Description:</b> The date and time that the notification was issued.</p> | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: date-time | +| fileInfoList | <p><b>Data Type:</b> array</p> <p><b>Description:</b> The list of one or more files included in this notification.</p> | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 1<br>uniqueItems: True<br>items: FileInfo | + +##### 4.2.1.4.28.3 Attribute constraints + +None. + +##### 4.2.1.4.28.4 State diagram + +None. + +##### 4.2.1.4.29 FileInfo <<datatype>> + +##### 4.2.1.4.29.1 Definition + +The FileInfo dataType represents the information about one or more generated files to be collected by a subscriber is now available for collection. + +The information representing the attributes of the FileInfo follows the provisions indicated in table 4.2.1.4.29.2-1. + +Table 4.2.1.4.29.2-1 Attributes Properties for FileInfo + +| Attribute name | Data Type/Description | Properties | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| fileLocation | <b>Data Type:</b> string<br><br><b>Description:</b> Location of the file | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uri | +| fileSize | <b>Data Type:</b> integer<br><br><b>Description:</b> Size of the file, unit is byte | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: int32<br>minimum: 0<br>x-units: bytes | +| fileReadyTime | <b>Data Type:</b> string<br><br><b>Description:</b> Date and time when the file was last closed and made available by the producer. The file content will not be changed any more | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: date-time | +| fileExpirationTime | <b>Data Type:</b> string<br><br><b>Description:</b> Date and time after which the file may be deleted. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: date-time | +| fileCompression | <b>Data Type:</b> string<br><br><b>Description:</b> If compression is applied to the file, the name of the compression algorithm used for compressing the file. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| fileDataType | <b>Data Type:</b> string | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>enum:<br>- PERFORMANCE<br>- ANALYTIC<br>- LOG | + +| Attribute name | Data Type/Description | Properties | +|----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------| +| | <b>Description:</b> An enumerated set of values identifying the type of data contained in the file. The valid set of values are described as follows:<br><b>PERFORMANCE:</b> The file contains a PerformanceMeasurementReport.<br><b>ANALYTIC:</b> The file contains analytic data.<br><b>LOG:</b> The file contains log entries identified in a logQuery request. | | + +##### 4.2.1.4.29.3 Attribute constraints + +None. + +###### 4.2.1.4.29.4 State diagram + +None. + +##### 4.2.1.4.30 Location + +###### 4.2.1.4.30.1 Definition + +The Location represents an instance of a Location where an O-Cloud Site may be available. + +###### 4.2.1.4.30.2 Attributes + +**Table 4.2.1.4.30.2-1 Attributes Properties for Location** + +| Attribute name | Data Type/Description | Properties | +|------------------|------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| globalLocationId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the location provided by the SMO as part of a lifecycle process. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable name of the location as identified by the cloud provider. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False | + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | description of the location as provided by the cloud provider. | x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| oCloudId | <b>Data Type:</b> string<br><br><b>Description:</b> Reference to the O-Cloud available at the location. | support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| coordinate | <b>Data Type:</b> string<br><br><b>Description:</b> The latitude and longitude of the location (shall be supplied if a postal address not provided). | support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| address | <b>Data Type:</b> string<br><br><b>Description:</b> Postal address of the facility (shall be supplied if a coordinate is not provided). | support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by the vendor to extend the information provided about the location. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | + +4.2.1.4.30.3 Attribute constraints + +None. + +4.2.1.4.30.4 State diagram + +None. + +4.2.1.4.31 OCloudSite + +4.2.1.4.31.1 Definition + +The OCloudSite represents an O-Cloud Site instance in an O-Cloud, as described in the O-RAN Cloud Architecture and Deployment Scenarios specification [i.3]. + +**Table 4.2.1.4.31.2-1 Attributes Properties for OCloudSite** + +| Attribute name | Data Type/Description | Properties | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| oCloudSiteId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the O-Cloud site. Locally unique within the scope of an O-Cloud instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| location | <b>Data Type:</b> Location<br><br><b>Description:</b> Location attributes where the O-Cloud site exists. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable name of the O-Cloud site as identified by the cloud provider. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable description of the O-Cloud site as provided by the cloud provider. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| oCloudId | <b>Data Type:</b> string<br><br><b>Description:</b> Reference to the O-Cloud of which the O-Cloud site is part. | support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| resourcePools | <b>Data Type:</b> array<br><br><b>Description:</b> List of resource pools that are part of the O-Cloud site. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True<br>items: ResourcePool | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0 | + +| Attribute name | Data Type/Description | Properties | +|----------------|-----------------------------------------------------------------------|-----------------------------------------------------------------------------------| +| | the vendor to extend the information provided about the O-Cloud site. | <div>uniqueItems: True</div> <div>items:</div> <div>AttributeVa<br/>luePair</div> | + +4.2.1.4.31.3 Attribute constraints + +None. + +4.2.1.4.31.4 State diagram + +None. + +4.2.1.4.32 LogQuery + +4.2.1.4.32.1 Definition + +The LogQuery represents a request for O-Cloud log files for specific resources or resource of specific ResourceTypes to be collected and made available to the requestor. + +4.2.1.4.32.2 Attributes + +**Table 4.2.1.4.32.2-1 Attributes Properties for LogQuery** + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| logType | <b>Data Type:</b> string<br><br><b>Description:</b> This identifies the type of log(s) to be collected. The exact list of valid log types to be discovered via a log capability discovery. | <div>x-support-qualifier: M</div> <div>x-isInvariant: False</div> <div>x-inventoryNotification: False</div> <div>x-stateChangeNotification: False</div> <div>nullable: False</div> | +| dateRanges | <b>Data Type:</b> array<br><br><b>Description:</b> list of date ranges that log data is to be extracted and placed into the log file for collection. | <div>x-support-qualifier: M</div> <div>x-isInvariant: False</div> <div>x-inventoryNotification: False</div> <div>x-stateChangeNotification: False</div> <div>nullable: False</div> <div>minItems: 1</div> <div>items: DateRange</div> | +| eventTypes | <b>Data Type:</b> array<br><br><b>Description:</b> List of event types that are to be extracted and placed in the log file for collection. The exact list of valid event types are to be discovered via a log capability discovery. | <div>x-support-qualifier: M</div> <div>x-isInvariant: False</div> <div>x-inventoryNotification: True</div> <div>x-stateChangeNotification: False</div> <div>nullable: True</div> <div>minItems: 0</div> <div>items: string</div> | + +| Attribute name | Data Type/Description | Properties | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| resources | <b>Data Type:</b> array<br><br><b>Description:</b> list of resource selection criteria to identify which resources are in scope for the query. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>items:<br><br>AttributeValuePair | +| resourceTypes | <b>Data Type:</b> array<br><br><b>Description:</b> list of resourceType selection criteria to identify which resources matching the resourceTypes are in scope for the query. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>items:<br><br>AttributeValuePair | +| logLevels | <b>Data Type:</b> array<br><br><b>Description:</b> List of logging levels that are to be extracted and placed in the log file for collection. The log levels specified in Clause 6.2.1, Table 2 of IETF RFC 5424 [5] shall be supported by the O-Cloud instance. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: True<br>minItems: 0<br>items: string | +| remoteFileLocation | <b>Data Type:</b> string<br><br><b>Description:</b> When the service is expected to push to a remote file system, this field is populated with the URL to the remote directory, otherwise the field is empty or not present. | support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>format: uri | +| callback | <b>Data Type:</b> string<br><br><b>Description:</b> The URL of the callback to which asynchronous notifications are delivered to.<br><br>If this attribute is an empty string or is not present, then the request is a synchronous request, and the query result will be supplied in the response. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>format: uri | + +| Attribute name | Data Type/Description | Properties | +|----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------| +| consumerLogRequestId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier optionally provided by the consumer for its purpose of tracking a request for log data. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | + +4.2.1.4.32.3 Attribute constraints + +None. + +4.2.1.4.32.4 State diagram + +None. + +4.2.1.4.33 DateRange <<dataType>> + +4.2.1.4.33.1 Definition + +The DateRange represent a start and end date and time value to indicate a span of time. + +4.2.1.4.33.2 Attributes + +**Table 4.2.1.4.33.2-1 Attributes Properties for DateRange** + +| Attribute name | Data Type/Description | Properties | +|----------------|------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------| +| startDateTime | <b>Data Type:</b> string<br><br><b>Description:</b> This identifies the start of a time range. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: date-time | +| endDateTime | <b>Data Type:</b> string<br><br><b>Description:</b> This identifies the end of a time range. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: date-time | + +4.2.1.4.33.3 Attribute constraints + +**Table 4.2.1.4.33.3-2 Attributes Constraints for DateRange** + +| Name | Definition | +|--------------------|-------------------------------------------------------------------------| +| START_PRECEDES_END | Condition: startDateTime shall chronologically precede the endDateTime. | + +##### 4.2.1.4.33.4 State diagram + +None. + +### 4.2.2 Namespace: ORAN.O2ims.Artifacts + +#### 4.2.2.1 Namespace Overview + +The O-RAN O2ims Artifacts namespace defines the classes and their attributes which are directly exposed to the consumer (SMO) via its O2 IMS Interface. + +This namespace is used for the O-Cloud artifacts e.g. Cluster Templates, Initial Configuration Sets, OS/SW/FW, etc. that e.g. The O-Cloud artifacts can be used for configuring O-Cloud Resources from the Inventory and Cluster namespaces. The artifacts are not consumed when they are used and can be referenced in the Inventory, Cluster and Provisioning structures. + +#### 4.2.2.2 Imported and associated information entities + +##### 4.2.2.2.1 Imported information entities and local labels + +Information entities imported into the model are also elements of the namespace and therefore shall remain unique within the namespace. + +**Table 4.2.2.2.1-1 Imported Entities** + +| Label reference | Local label | +|-----------------|-------------| +| | | +| | | + +##### 4.2.2.2.2 Associated information entities and local labels + +Information entities referenced in the model through an association which may be extended and overloaded with a new entity of the same name within the namespace are listed in the associated entities table. + +**Table 4.2.2.2.2-1 Associated Entities** + +| Label reference | Local label | +|-------------------------------------------|--------------------------------| +| 4.2.1.2.1 Top | Top | +| 4.2.1.4.7, InfrastructureInventoryObject_ | InfrastructureInventoryObject_ | + +#### 4.2.2.3 Class Diagram + +##### 4.2.2.3.1 Relationships + +###### 4.2.2.3.1.1 Description + +This clause depicts the set of classes (e.g. IOCs) that encapsulates the information relevant for the O-RAN Cloud (O-Cloud). This clause provides an overview of the relationships between relevant classes in UML. Subsequent clauses provide more detailed specification of various aspects of these classes. The UML Class + +diagram depicts a view of the namespace maintaining a defined focus so as not to overcrowd a single diagram trying to depict all relationships within the namespace. + +###### 4.2.2.3.1.2 ORAN.O2ims.Artifacts Intra-Namespace Relationships + +![Diagram showing intra-namespace relationships within ORAN.O2ims.Artifacts. It contains two classes: «InformationObjectClass» ArtifactResource and «InformationObjectClass» ArtifactResourceType. ArtifactResource has a self-referencing arrow labeled 'ReferenceOrUse' and a downward arrow labeled 'isOfType' pointing to ArtifactResourceType.](912801004a484f9c1deaa1c598fe178d_img.jpg) + +``` + +classDiagram + class ArtifactResource["«InformationObjectClass»\nArtifactResource"] + class ArtifactResourceType["«InformationObjectClass»\nArtifactResourceType"] + ArtifactResource --> ArtifactResource : ReferenceOrUse + ArtifactResource --> ArtifactResourceType : isOfType + +``` + +Diagram showing intra-namespace relationships within ORAN.O2ims.Artifacts. It contains two classes: «InformationObjectClass» ArtifactResource and «InformationObjectClass» ArtifactResourceType. ArtifactResource has a self-referencing arrow labeled 'ReferenceOrUse' and a downward arrow labeled 'isOfType' pointing to ArtifactResourceType. + +**Figure 4.2.2.3.1.2-1 ORAN.O2ims.Artifacts Intra-Namespace Relationships** + +###### 4.2.2.3.1.3 ORAN.O2ims.Artifacts Inter-Namespace Relationships + +![Diagram showing inter-namespace relationships. Three namespaces are shown: ORAN.O2ims.Cluster (containing NodeCluster and ClusterResource), ORAN.O2ims.Infrastructure (containing InfrastructureResource), and ORAN.O2ims.Artifacts (containing «InformationObjectClass» ArtifactResource). Red arrows labeled 'BasedOn' point from NodeCluster, ClusterResource, and InfrastructureResource to ArtifactResource.](c3a65b457676a37b38f779a731b083b9_img.jpg) + +``` + +classDiagram + namespace ORAN.O2ims.Cluster { + NodeCluster + ClusterResource + } + namespace ORAN.O2ims.Infrastructure { + InfrastructureResource + } + namespace ORAN.O2ims.Artifacts { + class ArtifactResource["«InformationObjectClass»\nArtifactResource"] + } + NodeCluster --> ArtifactResource : BasedOn + ClusterResource --> ArtifactResource : BasedOn + InfrastructureResource --> ArtifactResource : BasedOn + +``` + +Diagram showing inter-namespace relationships. Three namespaces are shown: ORAN.O2ims.Cluster (containing NodeCluster and ClusterResource), ORAN.O2ims.Infrastructure (containing InfrastructureResource), and ORAN.O2ims.Artifacts (containing «InformationObjectClass» ArtifactResource). Red arrows labeled 'BasedOn' point from NodeCluster, ClusterResource, and InfrastructureResource to ArtifactResource. + +**Figure 4.2.2.3.1.3-1 ORAN.O2ims.Artifacts Inter-Namespace Relationships** + +##### 4.2.2.3.2 Inheritance + +###### 4.2.2.3.2.1 ORAN.O2ims.Artifacts Inheritance + +![UML class diagram showing inheritance for ORAN.O2ims.Artifacts. The diagram is divided into two packages. The top package, ORAN.O2ims.Inventory, contains two classes: «InformationObjectClass» Top and «InformationObjectClass» InfrastructureInventoryObject_. The bottom package, ORAN.O2ims.Artifacts, contains two classes: «InformationObjectClass» ArtifactResourceType and «InformationObjectClass» ArtifactResource. Arrows indicate inheritance: InfrastructureInventoryObject_ inherits from Top, and both ArtifactResourceType and ArtifactResource inherit from InfrastructureInventoryObject_.](8b245a6dacebb70627ad76c1c03809aa_img.jpg) + +``` + +classDiagram + class Top["«InformationObjectClass» Top"] + class InfrastructureInventoryObject_["«InformationObjectClass» InfrastructureInventoryObject_"] + class ArtifactResourceType["«InformationObjectClass» ArtifactResourceType"] + class ArtifactResource["«InformationObjectClass» ArtifactResource"] + + Top <|-- InfrastructureInventoryObject_ + InfrastructureInventoryObject_ <|-- ArtifactResourceType + InfrastructureInventoryObject_ <|-- ArtifactResource + +``` + +UML class diagram showing inheritance for ORAN.O2ims.Artifacts. The diagram is divided into two packages. The top package, ORAN.O2ims.Inventory, contains two classes: «InformationObjectClass» Top and «InformationObjectClass» InfrastructureInventoryObject\_. The bottom package, ORAN.O2ims.Artifacts, contains two classes: «InformationObjectClass» ArtifactResourceType and «InformationObjectClass» ArtifactResource. Arrows indicate inheritance: InfrastructureInventoryObject\_ inherits from Top, and both ArtifactResourceType and ArtifactResource inherit from InfrastructureInventoryObject\_. + +**Figure 4.2.2.3.2.1-1 ORAN.O2ims.Artifacts Inheritance** + +#### 4.2.2.4 Class Definitions + +##### 4.2.2.4.1 ArtifactResourceType + +###### 4.2.2.4.1.1 Definition + +The ArtifactResourceType represents a resource type for a stored artifact resource in an O-Cloud. + +Artifact resource types provide the categorization of O-Cloud artifacts used as declarative templates or binary images for provisioning or deployment. The values for these types are used to build the inventory with provisioning enablers. The O-Cloud provides a mechanism to discover data about artifacts with respective operations on artifact resource types. + +The ArtifactResourceType is a Specialized Object that derives from a Generalized Object, the InfrastructureInventoryObject. The ArtifactResourceType inherits the attributes from the InfrastructureInventoryObject and allows it and all specializations of this class to be included in a change notification. + +###### 4.2.2.4.1.2 Attributes + +**Table 4.2.2.4.1.2-1 Attributes Properties for ArtifactResourceType** + +| Attribute name | Data Type/Description | Properties | +|------------------------|----------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------| +| artifactResourceTypeId | <b>Data Type:</b> string<br><br><b>Description:</b> Cloud unique identifier for the artifact | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | + +| Attribute name | Data Type/Description | Properties | +|----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | type. | format: uuid | +| name | <b>Data Type:</b> string<br><b>Description:</b> Human readable name for the artifact type. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><b>Description:</b> Description of the artifact type. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| extensions | <b>Data Type:</b> array<br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by the vendor to extend the information provided about the artifact resource type. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair | + +###### 4.2.2.4.1.3 Attribute constraints + +None. + +###### 4.2.2.4.1.4 State diagram + +None. + +##### 4.2.2.4.2 ArtifactResource + +###### 4.2.2.4.2.1 Definition + +The ArtifactResource represents a stored artifact resource in an O-Cloud. + +ArtifactResource provides the ability to expose information about the artifact that is needed by consumers without the need of parsing the artifact itself by the consumer. The O-Cloud provides a mechanism to discover new artifacts with respective operations on artifact resources. + +The ArtifactResource is a Specialized Object that derives from a Generalized Object, the InfrastructureInventoryObject. The ArtifactResource inherits the attributes from the InfrastructureInventoryObject and allows it and all specializations of this class to be included in a change notification. + +###### 4.2.2.4.2.2 + +###### Attributes + +Table 4.2.2.4.2.2-1 Attributes Properties for ArtifactResource + +| Attribute name | Data Type/Description | Properties | +|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| artifactResourceId | <b>Data Type:</b> string<br><br><b>Description:</b> O-Cloud unique identifier for the artifact. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable name of the artifact. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| version | <b>Data Type:</b> string<br><br><b>Description:</b> Version of the artifact. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Description of the artifact. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| parameterSchema | <b>Data Type:</b> array<br><br><b>Description:</b> Properties (keys) which are tailored by the artifact composition when it is to be used as a parameterized template. See NOTE. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair | +| NOTE: Since the ArtifactResource is generic for any kind of artifact at an information model level, no keys are specified since this would have dependency on the kind of resource to which the artifact applies. | | | + +###### 4.2.2.4.2.3 + +###### Attribute constraints + +None. + +###### 4.2.2.4.2.4 + +###### State diagram + +None. + +### 4.2.3 Namespace: ORAN.O2ims.Cluster + +#### 4.2.3.1 Namespace Overview + +The O-RAN O2ims Cluster namespace defines the classes and their attributes which are directly exposed to the consumer (SMO) via its O2 IMS Interface. + +This namespace is used for the provisioned O-Cloud Node Clusters with status and metrics as well as its internal topologies. The O-Cloud Node Clusters are assembled based on the ORAN.O2ims.Inventory objects and configured through ORAN.O2ims.Artifacts. + +#### 4.2.3.2 Imported and associated information entities + +##### 4.2.3.2.1 Imported information entities and local labels + +Information entities imported into the model are also elements of the namespace and therefore shall remain unique within the namespace. + +**Table 4.2.3.2.1-1 Imported Entities** + +| Label reference | Local label | +|-----------------|-------------| +| | | +| | | + +##### 4.2.3.2.2 Associated information entities and local labels + +Information entities referenced in the model through an association which may be extended and overloaded with a new entity of the same name within the namespace are listed in the associated entities table. + +**Table 4.2.3.2.2-1 Associated Entities** + +| Label reference | Local label | +|------------------------------------------------|--------------------------------------| +| 4.2.1.4.7 <i>InfrastructureInventoryObject</i> | <i>InfrastructureInventoryObject</i> | +| | | + +#### 4.2.3.3 Class Diagram + +##### 4.2.3.3.1 Relationships + +###### 4.2.3.3.1.1 Description + +This clause depicts the set of classes (e.g. IOCs) that encapsulates the information relevant for the O-RAN Cloud (O-Cloud). This clause provides an overview of the relationships between relevant classes in UML. Subsequent clauses provide more detailed specification of various aspects of these classes. The UML Class diagram depicts a view of the namespace maintaining a defined focus so as not to overcrowd a single diagram trying to depict all relationships within the namespace. + +###### 4.2.3.3.1.2 ORAN.O2ims.Cluster Intra-Namespaces Relationships + +![Diagram showing intra-namespace relationships within the ORAN.O2ims.Cluster namespace. It includes classes like NodeCluster, ClusterResourceGroup, ClusterResource, NodeClusterType, and ClusterResourceType with their respective associations and multiplicities.](6159b4922e8f70f4e640e09c82c5ecc4_img.jpg) + +``` + +classDiagram + class NodeCluster["«InformationObjectClass»\nNodeCluster"] + class ClusterResourceGroup["«InformationObjectClass»\nClusterResourceGroup"] + class ClusterResource["«InformationObjectClass»\nClusterResource"] + class NodeClusterType["«InformationObjectClass»\nNodeClusterType"] + class ClusterResourceType["«InformationObjectClass»\nClusterResourceType"] + + NodeCluster "1" -- "0..N" ClusterResourceGroup : +clusterResourceGroups + NodeCluster "1" -- "1..N" ClusterResource : +clusterResourceIds + NodeCluster "1" -- "1" NodeClusterType : Has + ClusterResourceGroup "1" -- "1..N" ClusterResource : +clusterResources + ClusterResource "1" -- "0..N" NodeClusterType : +memberOf + ClusterResource "1" -- "1" ClusterResourceType : Has + +``` + +Diagram showing intra-namespace relationships within the ORAN.O2ims.Cluster namespace. It includes classes like NodeCluster, ClusterResourceGroup, ClusterResource, NodeClusterType, and ClusterResourceType with their respective associations and multiplicities. + +###### 4.2.3.3.1.2-1 ORAN.O2ims.Cluster Intra-Namespaces Relationships + +###### 4.2.3.3.1.3 ORAN.O2ims.Cluster Inter-Namespaces Relationships + +![Diagram showing inter-namespace relationships between ORAN.O2ims.Cluster and other namespaces like ORAN.O2ims.Infrastructure, ORAN.O2ims.Provisioning, ORAN.O2ims.Inventory, and ORAN.O2ims.Artifacts.](f57787850f7b49f95e84debdc363e80b_img.jpg) + +``` + +classDiagram + class InfrastructureResource["«InformationObjectClass»\nInfrastructureResource"] + class ProvisioningRequest["«InformationObjectClass»\nProvisioningRequest"] + class Resource["«InformationObjectClass»\nResource"] + class ClusterResource["«InformationObjectClass»\nClusterResource"] + class NodeCluster["«InformationObjectClass»\nNodeCluster"] + class ArtifactResource["«InformationObjectClass»\nArtifactResource"] + + InfrastructureResource ..> ClusterResource : This relation will exist but its exact definitions are dependent on the definition of specialized classes within each namespace. + ProvisioningRequest --> NodeCluster : Fulfill + Resource --> ClusterResource : MappedTo + ClusterResource "0..N" -- "0..N" ArtifactResource : +artifactResourceIds + NodeCluster --> ArtifactResource : BasedOn + +``` + +Diagram showing inter-namespace relationships between ORAN.O2ims.Cluster and other namespaces like ORAN.O2ims.Infrastructure, ORAN.O2ims.Provisioning, ORAN.O2ims.Inventory, and ORAN.O2ims.Artifacts. + +Figure 4.2.3.3.1.3-1 ORAN.O2ims.Cluster Inter-Namespaces Relationships + +##### 4.2.3.3.2 Inheritance + +###### 4.2.3.3.2.1 ORAN.O2ims.Cluster Inheritance + +![UML class diagram showing ORAN.O2ims.Cluster Inheritance. The diagram shows a hierarchy where ORAN.O2ims.Cluster is a specialization of ORAN.O2ims.Inventory. ORAN.O2ims.Cluster contains several subclasses: ClusterResource, ClusterResourceGroup, NodeClusterType, ClusterResourceType, and NodeCluster. ClusterResourceGroup is further specialized by Top. All classes are marked as «InformationObjectClass».](05b4bb77477b40c58cc1fe4078f485af_img.jpg) + +``` + +classDiagram + class ORAN_O2ims_Inventory["ORAN.O2ims.Inventory"] { + <<InformationObjectClass>> + InfrastructureInventoryObject_ + } + class ORAN_O2ims_Cluster["ORAN.O2ims.Cluster"] { + <<InformationObjectClass>> + ClusterResource + ClusterResourceGroup + NodeClusterType + ClusterResourceType + NodeCluster + } + class ClusterResource { + <<InformationObjectClass>> + } + class ClusterResourceGroup { + <<InformationObjectClass>> + } + class NodeClusterType { + <<InformationObjectClass>> + } + class ClusterResourceType { + <<InformationObjectClass>> + } + class NodeCluster { + <<InformationObjectClass>> + } + class Top { + <<InformationObjectClass>> + } + + ORAN_O2ims_Inventory <|-- ORAN_O2ims_Cluster + ORAN_O2ims_Cluster <|-- ClusterResource + ORAN_O2ims_Cluster <|-- ClusterResourceGroup + ORAN_O2ims_Cluster <|-- NodeClusterType + ORAN_O2ims_Cluster <|-- ClusterResourceType + ORAN_O2ims_Cluster <|-- NodeCluster + ClusterResourceGroup <|-- Top + +``` + +UML class diagram showing ORAN.O2ims.Cluster Inheritance. The diagram shows a hierarchy where ORAN.O2ims.Cluster is a specialization of ORAN.O2ims.Inventory. ORAN.O2ims.Cluster contains several subclasses: ClusterResource, ClusterResourceGroup, NodeClusterType, ClusterResourceType, and NodeCluster. ClusterResourceGroup is further specialized by Top. All classes are marked as «InformationObjectClass». + +**Figure 4.3.2.2.1-1 ORAN.O2ims.Cluster Inheritance** + +#### 4.2.3.4 Class Definitions + +##### 4.2.3.4.1 NodeClusterType + +###### 4.2.3.4.1.1 Definition + +The NodeClusterType represents a resource type for a NodeCluster in an O-Cloud. + +Node cluster types provide the categorization of O-Cloud resource types used to create a node cluster. The O-Cloud provides a mechanism to discover the node cluster types with respective operations on node cluster types. + +The NodeClusterType is a Specialized Object that derives from a Generalized Object, the InfrastructureInventoryObject. The NodeClusterType inherits the attributes from the InfrastructureInventoryObject and allows it and all specializations of this class to be included in a change notification. + +###### 4.2.3.4.1.2 Attributes + +**Table 4.2.3.4.1.2-1 Attributes Properties for NodeClusterType** + +| Attribute name | Data Type/Description | Properties | +|-------------------|---------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| NodeClusterTypeId | <b>Data Type:</b> string<br><br><b>Description:</b> Unique identifier for the NodeClusterType instance. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Name of the Node Cluster Type. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | + +| Attribute name | Data Type/Description | Properties | +|----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable description of the Node Cluster Type. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored extend the information provided about the Node Cluster Type. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | + +###### 4.2.3.4.1.3 Attribute constraints + +None. + +###### 4.2.3.4.1.4 State diagram + +None. + +##### 4.2.3.4.2 NodeCluster + +###### 4.2.3.4.2.1 Definition + +The NodeCluster represents a set of resource used to deploy workloads in an O-Cloud. + +Node cluster provides inventory of the resources used in a NodeCluster. The O-Cloud provides a mechanism to discover the node cluster with respective operations on node clusters. + +The NodeCluster is a Specialized Object that derives from a Generalized Object, the InfrastructureInventoryObject. The NodeCluster inherits the attributes from the InfrastructureInventoryObject and allows it and all specializations of this class to be included in a change notification. + +###### 4.2.3.4.2.2 Attributes + +**Table 4.2.3.4.1.2-1 Attributes Properties for NodeCluster** + +| Attribute name | Data Type/Description | Properties | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| nodeClusterId | <b>Data Type:</b> string<br><br><b>Description:</b> Unique identifier for the NodeCluster instance assigned by the O-Cloud. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| clientNodeClusterId | <b>Data Type:</b> string | x-support-qualifier: M<br>x-isInvariant: True | + +| Attribute name | Data Type/Description | Properties | +|--------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <b>Description:</b> Unique identifier for the NodeCluster instance assigned by the consumer who requested its creation. | x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><b>Description:</b> Name of the NodeCluster. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><b>Description:</b> Human readable description of the NodeCluster. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| extensions | <b>Data Type:</b> array<br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored extend the information provided about the NodeCluster. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | +| clusterDistributionDescription | <b>Data Type:</b> string<br><b>Description:</b> Human readable text identifying the method of distribution of ClusterResources over O-Cloud Sites. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| NodeClusterTypeId | <b>Data Type:</b> string<br><b>Description:</b> Identifier for the NodeClusterType that this NodeCluster is. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| artifactResourceId | <b>Data Type:</b> string<br><b>Description:</b> Identifier for the template artifact which this NodeCluster is based on. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| clusterResourceIds | <b>Data Type:</b> array<br><b>Description:</b> The list of cluster resource identifiers that are used to construct | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True | + +| Attribute name | Data Type/Description | Properties | +|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | this NodeCluster. | <div>items: string</div> <div>format: uuid</div> | +| clusterResourceGroups | <b>Data Type:</b> array<br><br><b>Description:</b> Optional list node groups that comprise the cluster resources which compose the NodeCluster. | <div>x-support-qualifier: M</div> <div>x-isInvariant: False</div> <div>x-inventoryNotification: True</div> <div>x-stateChangeNotification: False</div> <div>nullable: True</div> <div>x-isOrdered: False</div> <div>minItems: 0</div> <div>uniqueItems: True</div> <div>items: string</div> <div>format: uuid</div> | + +###### 4.2.3.4.2.3 Attribute constraints + +None. + +###### 4.2.3.4.2.4 State diagram + +None. + +##### 4.2.3.4.3 ClusterResourceType + +###### 4.2.3.4.3.1 Definition + +The ClusterResourceType represents a resource type for a ClusterResource in an O-Cloud. + +Cluster resource types provide the categorization of O-Cloud resource types used to create a node cluster. The O-Cloud provides a mechanism to discover the cluster resource types with respective operations on cluster resource types. + +The ClusterResourceType is a Specialized Object that derives from a Generalized Object, the InfrastructureInventoryObject. The ClusterResourceType inherits the attributes from the InfrastructureInventoryObject and allows it and all specializations of this class to be included in a change notification. + +###### 4.2.3.4.3.2 Attributes + +**Table 4.2.3.4.3.2-1 Attributes Properties for ClusterResourceType** + +| Attribute name | Data Type/Description | Properties | +|-----------------------|-------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| clusterResourceTypeId | <b>Data Type:</b> string<br><br><b>Description:</b> Unique identifier for the ClusterResourceType instance. | <div>x-support-qualifier: M</div> <div>x-isInvariant: True</div> <div>x-inventoryNotification: True</div> <div>x-stateChangeNotification: False</div> <div>nullable: False</div> <div>format: uuid</div> | +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Name of the Cluster Resource Type. | <div>x-support-qualifier: M</div> <div>x-isInvariant: False</div> <div>x-inventoryNotification: True</div> <div>x-stateChangeNotification: False</div> <div>nullable: False</div> | +| description | <b>Data Type:</b> string | <div>x-support-qualifier: M</div> | + +| Attribute name | Data Type/Description | Properties | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <b>Description:</b> Human readable description of the Cluster Resource Type. | x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored extend the information provided about the Cluster Resource Type. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | + +###### 4.2.3.4.3.3 Attribute constraints + +None. + +###### 4.2.3.4.3.4 State diagram + +None. + +##### 4.2.3.4.4 ClusterResource + +###### 4.2.3.4.4.1 Definition + +The ClusterResource represents a resource used to construct a NodeCluster in an O-Cloud. + +Node cluster resource provides inventory of the resources used in a NodeCluster. The O-Cloud provides a mechanism to discover the node cluster resources with respective operations on node cluster resources. + +The ClusterResource is a Specialized Object that derives from a Generalized Object, the InfrastructureInventoryObject. The ClusterResource inherits the attributes from the InfrastructureInventoryObject and allows it and all specializations of this class to be included in a change notification. + +###### 4.2.3.4.4.2 Attributes + +**Table 4.2.3.4.4.2-1 Attributes Properties for ClusterResource** + +| Attribute name | Data Type/Description | Properties | +|-------------------|---------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------| +| clusterResourceId | <b>Data Type:</b> string<br><br><b>Description:</b> Unique identifier for the ClusterResource instance. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Name of the cluster resource. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | + +| Attribute name | Data Type/Description | Properties | +|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable description of the cluster resource. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored extend the information provided about the Cluster Resource. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | +| clusterResourceTypeid | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier for the ClusterResourceType for this resource. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| memberOf | <b>Data Type:</b> array<br><br><b>Description:</b> list of other ClusterResources which are linked together. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: string | +| artifactResourceIds | <b>Data Type:</b> array<br><br><b>Description:</b> Identifiers for the artifact(s) which this resource is based on. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: string<br>format: uuid | +| resourceId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier for the inventory resource which this resource is mapped to. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | + +###### 4.2.3.4.4.3 + +###### Attribute constraints + +None. + +###### 4.2.3.4.4.4 State diagram + +None. + +##### 4.2.3.4.5 ClusterResourceGroup + +###### 4.2.3.4.5.1 Definition + +The ClusterResourceGroup represents a collection of ClusterResources as a named set. + +###### 4.2.3.4.5.2 Attributes + +**Table 4.2.3.4.5.2-1 Attributes Properties for ClusterResourceGroup** + +| Attribute name | Data Type/Description | Properties | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| clusterResourceGroupId | <b>Data Type:</b> string<br><br><b>Description:</b> Unique identifier for the ClusterResourceGroup. | x-support-qualifier: M<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Name of the Node Group. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable description of the ClusterResourceGroup. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored extend the information provided about the ClusterResourceGroup. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | +| clusterResources | <b>Data Type:</b> array<br><br><b>Description:</b> The list of Cluster Resources belonging to this ClusterResourceGroup. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True<br>items: string<br>format: uuid | + +###### 4.2.3.4.5.3 Attribute constraints + +None. + +###### 4.2.3.4.5.4 State diagram + +None. + +### 4.2.4 Namespace: ORAN.O2ims.Provisioning + +#### 4.2.4.1 Namespace Overview + +The O-RAN O2ims Provisioning namespace defines the classes and their attributes which are directly exposed to the consumer (SMO) via its O2 IMS Interface. + +This namespace is used for provisioning requests and fulfillments, e.g. of O-Cloud Node Clusters, representing the requested and agreed service levels and their current identifiers. + +#### 4.2.4.2 Imported and associated information entities + +##### 4.2.4.2.1 Imported information entities and local labels + +Information entities imported into the model are also elements of the namespace and therefore shall remain unique within the namespace. + +**Table 4.2.4.2.1-1 Imported Entities** + +| Label reference | Local label | +|----------------------------------------------|-------------| +| TS 28.622 [6], information object class, Top | Top | +| | | + +##### 4.2.4.2.2 Associated information entities and local labels + +Information entities referenced in the model through an association which may be extended and overloaded with a new entity of the same name within the namespace are listed in the associated entities table. + +**Table 4.2.4.2.2-1 Associated Entities** + +| Label reference | Local label | +|-----------------|-------------| +| | | +| | | + +#### 4.2.4.3 Class Diagram + +##### 4.2.4.3.1 Relationships + +###### 4.2.4.3.1.1 Description + +This clause depicts the set of classes (e.g. IOCs) that encapsulates the information relevant for the O-RAN Cloud (O-Cloud). This clause provides an overview of the relationships between relevant classes in UML. Subsequent clauses provide more detailed specification of various aspects of these classes. The UML Class diagram depicts a view of the namespace maintaining a defined focus so as not to overcrowd a single diagram trying to depict all relationships within the namespace. + +###### 4.2.4.3.1.2 ORAN.O2ims.Provisioning Intra-Namespaces Relationships + +![Figure 4.2.4.3.1.2-1 ORAN.O2ims.Provisioning Intra-Namespaces Relationships. This diagram shows the internal structure of the ORAN.O2ims.Provisioning namespace. It contains three classes: «InformationObjectClass» ProvisioningRequest, «dataType» ProvisioningStatus, and «enumeration» ProvisioningPhase. A yellow arrow points from ProvisioningRequest to ProvisioningStatus. A yellow callout box with a note says 'Current specification does not define the enumerated set of this type' pointing to ProvisioningPhase. A yellow line connects ProvisioningStatus and ProvisioningPhase.](1dcfae33560a791008cdc9e3369d4e0f_img.jpg) + +Figure 4.2.4.3.1.2-1 ORAN.O2ims.Provisioning Intra-Namespaces Relationships. This diagram shows the internal structure of the ORAN.O2ims.Provisioning namespace. It contains three classes: «InformationObjectClass» ProvisioningRequest, «dataType» ProvisioningStatus, and «enumeration» ProvisioningPhase. A yellow arrow points from ProvisioningRequest to ProvisioningStatus. A yellow callout box with a note says 'Current specification does not define the enumerated set of this type' pointing to ProvisioningPhase. A yellow line connects ProvisioningStatus and ProvisioningPhase. + +Figure 4.2.4.3.1.2-1 ORAN.O2ims.Provisioning Intra-Namespaces Relationships + +###### 4.2.4.3.1.3 ORAN.O2ims.Provisioning Inter-Namespaces Relationships + +![Figure 4.2.4.3.1.3-1 ORAN.O2ims.Provisioning Inter-Namespaces Relationships. This diagram shows the relationships between four namespaces: ORAN.O2ims.Infrastructure, ORAN.O2ims.Artifacts, ORAN.O2ims.Provisioning, and ORAN.O2ims.Cluster. ORAN.O2ims.Provisioning (containing «InformationObjectClass» ProvisioningRequest) is the central element. It has a 0..N relationship with ORAN.O2ims.Infrastructure (containing «InformationObjectClass» InfrastructureResource) via the role +infrastructureResourceIds. It has a 1 relationship with ORAN.O2ims.Artifacts (containing «InformationObjectClass» Template) via the role +provisioningRequestId. It has a 1 relationship with ORAN.O2ims.Cluster (containing «InformationObjectClass» NodeCluster) via the role +provisioningRequestId. Additionally, ORAN.O2ims.Provisioning has a 0..N relationship with ORAN.O2ims.Cluster via the role +nodeClusterId. A 'accordingTo' relationship is shown from ORAN.O2ims.Artifacts to ORAN.O2ims.Provisioning.](e8d50d4e356e9bf73e34786dd1ef28a0_img.jpg) + +Figure 4.2.4.3.1.3-1 ORAN.O2ims.Provisioning Inter-Namespaces Relationships. This diagram shows the relationships between four namespaces: ORAN.O2ims.Infrastructure, ORAN.O2ims.Artifacts, ORAN.O2ims.Provisioning, and ORAN.O2ims.Cluster. ORAN.O2ims.Provisioning (containing «InformationObjectClass» ProvisioningRequest) is the central element. It has a 0..N relationship with ORAN.O2ims.Infrastructure (containing «InformationObjectClass» InfrastructureResource) via the role +infrastructureResourceIds. It has a 1 relationship with ORAN.O2ims.Artifacts (containing «InformationObjectClass» Template) via the role +provisioningRequestId. It has a 1 relationship with ORAN.O2ims.Cluster (containing «InformationObjectClass» NodeCluster) via the role +provisioningRequestId. Additionally, ORAN.O2ims.Provisioning has a 0..N relationship with ORAN.O2ims.Cluster via the role +nodeClusterId. A 'accordingTo' relationship is shown from ORAN.O2ims.Artifacts to ORAN.O2ims.Provisioning. + +Figure 4.2.4.3.1.3-1 ORAN.O2ims.Provisioning Inter-Namespaces Relationships + +##### 4.2.4.3.2 Inheritance + +###### 4.2.4.3.2.1 ORAN.O2ims.Provisioning Inheritance + +![Figure 4.2.4.3.2.1-1 ORAN.O2ims.Provisioning Inheritance. This diagram shows an inheritance relationship between two classes. The base class is «InformationObjectClass» Top. The derived class is «InformationObjectClass» ProvisioningRequest. A hollow triangle arrow points from ProvisioningRequest to Top, indicating that ProvisioningRequest inherits from Top.](53fd4314b6c11a23275810dd5e13b019_img.jpg) + +Figure 4.2.4.3.2.1-1 ORAN.O2ims.Provisioning Inheritance. This diagram shows an inheritance relationship between two classes. The base class is «InformationObjectClass» Top. The derived class is «InformationObjectClass» ProvisioningRequest. A hollow triangle arrow points from ProvisioningRequest to Top, indicating that ProvisioningRequest inherits from Top. + +Figure 4.2.4.3.2.1-1 ORAN.O2ims.Provisioning Inheritance + +#### 4.2.4.4 Class Definitions + +##### 4.2.4.4.1 ProvisioningRequest + +###### 4.2.4.4.1.1 Definition + +The ProvisioningRequest represents a request for item(s) to be provisioned in the O-Cloud. The SMO makes the declarative request to the O-Cloud through the O2ims. + +###### 4.2.4.4.1.2 Attributes + +**Table 4.2.4.4.1.2-1 Attributes Properties for ProvisioningRequest** + +| Attribute name | Data Type/Description | Properties | +|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| provisioningRequestId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the provisioning request instance assigned by the SMO. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable name of the provisioning request instance as assigned by the SMO. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable description of the provisioning request instance as assigned by the SMO. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| templateName | <b>Data Type:</b> string<br><br><b>Description:</b> Name of the template to be used as the basis for the declarative model for the provisioning request instance. When combined with the templateVersion it shall resolve to a templateId. It is provided on the create request but cannot be modified with a later update request. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| templateVersion | <b>Data Type:</b> string<br><br><b>Description:</b> Version of the template used as the basis | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False | + +| Attribute name | Data Type/Description | Properties | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | for the declarative model for the provisioning request instance. When combined with the templateName it shall resolve to a templateId. | nullable: False | +| templateParameters | <b>Data Type:</b> array<br><b>Description:</b> List of variables/value pairs used within the template to tailor the template to this request instance. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair | +| status | <b>Data Type:</b> ProvisioningStatus<br><b>Description:</b> The time of the last message and the current ProvisioningPhase of the ProvisioningRequest. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False | +| nodeClusterId | <b>Data Type:</b> String<br><b>Description:</b> If the request is fulfilled by a NodeCluster this field will contain its Id. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: True<br>format: uuid | +| infrastructureResourceIds | <b>Data Type:</b> array<br><b>Description:</b> If the request is fulfilled by InfrastructureResource(s) this list will contain the Id(s) of all resources used to fulfil it. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: string | + +###### 4.2.4.4.1.3 Attribute constraints + +**Table 4.2.4.4.1.3-3 Attributes Constraints for ProvisioningRequest** + +| Name | Definition | +|---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| ReadOnlyAfterCreate | The following attributes are provided by the SMO on the create request but are readOnly afterwards: ProvisioningRequestId, templateName, templateVersion | + +###### 4.2.4.4.1.4 State diagram + +None. + +##### 4.2.4.4.2 ProvisioningStatus <<dataType>> + +###### 4.2.4.4.2.1 Definition + +The ProvisioningStatus represents the status of a ProvisioningRequest indicating the time of the last message and the current ProvisioningPhase. + +###### 4.2.4.4.2.2 Attributes + +**Table 4.2.4.4.2.2-1 Attributes Properties for ProvisioningStatus** + +| Attribute name | Data Type/Description | Properties | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| updateTime | <b>Data Type:</b> string<br><br><b>Description:</b> The last date and time that the provisioningPhase attribute was modified. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False<br>format: date-time | +| message | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable text about the provisioningPhase at the last updateTime. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False | +| provisioningPhase | <b>Data Type:</b> ProvisioningPhase<br><br><b>Description:</b> Current phase of the provisioning request. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False | + +###### 4.2.4.4.2.3 Attribute constraints + +None. + +###### 4.2.4.4.2.4 State diagram + +None. + +### 4.2.5 Namespace: ORAN.O2ims.Infrastructure + +#### 4.2.5.1 Namespace Overview + +The O-RAN O2ims Infrastructure namespace defines the classes and their attributes which are directly exposed to the consumer (SMO) via its O2 IMS Interface. + +This namespace is used for fulfillment of provisioning requests which produce configured resources for later provisioning requests. + +#### 4.2.5.2 Imported and associated information entities + +##### 4.2.5.2.1 Imported information entities and local labels + +Information entities imported into the model are also elements of the namespace and therefore shall remain unique within the namespace. + +**Table 4.2.5.2.1-1 Imported Entities** + +| Label reference | Local label | +|-----------------|-------------| +| | | +| | | + +##### 4.2.5.2.2 Associated information entities and local labels + +Information entities referenced in the model through an association which may be extended and overloaded with a new entity of the same name within the namespace are listed in the associated entities table. + +**Table 4.2.5.2.2-1 Associated Entities** + +| Label reference | Local label | +|--------------------------------------------------|---------------------------------------| +| 4.2.1.4.7, <i>InfrastructureInventoryObject_</i> | <i>InfrastructureInventoryObject_</i> | +| | | + +#### 4.2.5.3 Class Diagram + +##### 4.2.5.3.1 Relationships + +###### 4.2.5.3.1.1 Description + +This clause depicts the set of classes (e.g. IOCs) that encapsulates the information relevant for the O-RAN Cloud (O-Cloud). This clause provides an overview of the relationships between relevant classes in UML. Subsequent clauses provide more detailed specification of various aspects of these classes. The UML Class diagram depicts a view of the namespace maintaining a defined focus so as not to overcrowd a single diagram trying to depict all relationships within the namespace. + +###### 4.2.5.3.1.2 ORAN.O2ims.Infrastructure Intra-Namespace Relationships + +The O-Cloud Networking consists of both intra- and inter-namespace relationships, which are complex in nature. The overview diagram (Figure 4.2.5.3.1.2-1) which simplifies the relationships has been drawn to help build a high-level understanding of the various object classes and their relationships. For example, a “Node” of type VM, BareMetal, and/or IaaS, which is a cluster resource type, terminates one or more site networks, which is an infrastructure resource type. Similarly, a gateway can terminate one or more site networks, forming an intra-namespace relationship since both the gateway and site networks belong to the infrastructure namespace. + +![Figure 4.2.5.3.1.2-1 O-Cloud Networking Overview diagram showing relationships between Node, SiteNW, Gateway, and AttachmentCircuit objects.](3bb217d736e020dc19ab241b0cc068f1_img.jpg) + +The diagram illustrates the O-Cloud Networking Overview. It shows a central horizontal line representing a network backbone. Above this line, two **Node** objects (labeled >ClusterResource and VM/BM/laaS) are connected to the backbone via **TerminatedBy** relationships. Below the backbone, a **SiteNW** object (labeled >InfraResource) is connected to the backbone via a **TerminatedBy** relationship. A **Gateway** object (labeled >InfraResource) is connected to the backbone via an **InterfaceIP [v4,v6, v4 and v6]** relationship. Two **AttachmentCircuit** objects (labeled >InfraResource) are connected to the backbone via **AttachTo** relationships. The entire diagram is labeled **O-Cloud** in the bottom left corner. + +Figure 4.2.5.3.1.2-1 O-Cloud Networking Overview diagram showing relationships between Node, SiteNW, Gateway, and AttachmentCircuit objects. + +**Figure 4.2.5.3.1.2-1 O-Cloud Networking Overview** + +These relationships, however, involve various elements and endpoints to support multiplicity, which introduces several implicit data types such as **Port**, **NetworkAddress**, and **SegmentationElement**. Each of these elements can include multiple endpoints representing a termination or an external connectivity attachment. These implicit data types and their relationships with O-Cloud Networking objects are captured in Figure 4.2.5.3.1.2-2, which illustrates the intra-namespaces relationships between specialized infrastructure namespace objects. + +There is a relationship between “Port” and “AttachmentCircuit” to represent the endpoint connectivity provided by “Port” for O-Cloud Site connectivity, using two possible associations to the transport network described in Clause 4.2.1.3.1.4.1. + +Note: This document version represents the relationship with a dotted line, as the O-Cloud Networking Information Model is still in development. + +![Figure 4.2.5.3.1.2-2 ORAN.O2ims.Infrastructure Intra-Namespaces Relationships. This diagram shows the internal relationships within the ORAN.O2ims.Infrastructure namespace. It includes classes like InfrastructureResourceType, SiteNetwork, InfrastructureResource, SegmentationElement, Port, NetworkAddress, Gateway, and AttachmentCircuit. Relationships are defined with multiplicities and roles such as 'isOfType', '+segmentation', '+attachedTo', and '+endPoints'.](7ea9cdba956cc18e13e5e69fa9f1830d_img.jpg) + +``` + +classDiagram + class InfrastructureResourceType["«InformationObjectClass» InfrastructureResourceType"] + class SiteNetwork["«InformationObjectClass» SiteNetwork"] + class InfrastructureResource["«InformationObjectClass» InfrastructureResource"] + class SegmentationElement["«dataType» SegmentationElement"] + class Port["«dataType» Port"] + class NetworkAddress["«dataType» NetworkAddress"] + class Gateway["«InformationObjectClass» Gateway"] + class AttachmentCircuit["«InformationObjectClass» AttachmentCircuit"] + + InfrastructureResourceType --|> InfrastructureResource : isOfType + SiteNetwork --> InfrastructureResource : 1 + SiteNetwork --> SegmentationElement : 1..N +segmentation + InfrastructureResource --> SegmentationElement : 0..N +linkedInfrastructureResourceSegmentation + SegmentationElement --> AttachmentCircuit : 1..N + AttachmentCircuit --> Port : 1 + Port --> NetworkAddress : 1..N +endPoints + Port --> Gateway : 1..N +connectedNetworks + Port --> Port : 1..N +attachedTo + +``` + +Figure 4.2.5.3.1.2-2 ORAN.O2ims.Infrastructure Intra-Namespaces Relationships. This diagram shows the internal relationships within the ORAN.O2ims.Infrastructure namespace. It includes classes like InfrastructureResourceType, SiteNetwork, InfrastructureResource, SegmentationElement, Port, NetworkAddress, Gateway, and AttachmentCircuit. Relationships are defined with multiplicities and roles such as 'isOfType', '+segmentation', '+attachedTo', and '+endPoints'. + +Figure 4.2.5.3.1.2-2 ORAN.O2ims.Infrastructure Intra-Namespaces Relationships + +###### 4.2.5.3.1.3 ORAN.O2ims.Infrastructure Inter-Namespaces Relationships + +![Figure 4.2.5.3.1.3-1 ORAN.O2ims.Infrastructure Inter-Namespaces Relationships. This diagram shows relationships between the ORAN.O2ims.Infrastructure namespace and other namespaces: ORAN.O2ims.Inventory, ORAN.O2ims.Artifacts, and ORAN.O2ims.Cluster. Relationships include 'realizedBy' and 'BasedOn' with multiplicities and roles like '+inventoryResourceIds' and '+artifactResourceIds'. A note indicates that the relationship with ORAN.O2ims.Cluster is dependent on specialized classes.](d5a595988c6a8e0e664f5f1bfe9839d3_img.jpg) + +``` + +classDiagram + class InventoryResource["«InformationObjectClass» Resource"] + class InfrastructureResource["«InformationObjectClass» InfrastructureResource"] + class ArtifactResource["«InformationObjectClass» ArtifactResource"] + class ClusterResource["«InformationObjectClass» ClusterResource"] + + InfrastructureResource --> InventoryResource : 1..N +inventoryResourceIds realizedBy + InfrastructureResource --> ArtifactResource : 1 BasedOn + InfrastructureResource -.-> ClusterResource : This relation will exist but its exact definitions are dependent on the definition of specialized classes within each namespace. + +``` + +Figure 4.2.5.3.1.3-1 ORAN.O2ims.Infrastructure Inter-Namespaces Relationships. This diagram shows relationships between the ORAN.O2ims.Infrastructure namespace and other namespaces: ORAN.O2ims.Inventory, ORAN.O2ims.Artifacts, and ORAN.O2ims.Cluster. Relationships include 'realizedBy' and 'BasedOn' with multiplicities and roles like '+inventoryResourceIds' and '+artifactResourceIds'. A note indicates that the relationship with ORAN.O2ims.Cluster is dependent on specialized classes. + +Figure 4.2.5.3.1.3-1 ORAN.O2ims.Infrastructure Inter-Namespaces Relationships + +##### 4.2.5.3.2 Inheritance + +###### 4.2.5.3.2.1 ORAN.O2ims.Infrastructure Inheritance + +![UML class diagram showing inheritance. ORAN.O2IMS.Inventory (InformationObjectClass InfrastructureInventoryObject_) is the superclass. ORAN.O2IMS.Infrastructure (InformationObjectClass InfrastructureResourceType and InformationObjectClass InfrastructureResource) are subclasses. Red arrows indicate inheritance from InfrastructureResourceType and InfrastructureResource to InfrastructureInventoryObject_.](61d84b465b9bbc737e54637bdea5ad37_img.jpg) + +``` + +classDiagram + class ORAN_O2IMS_Inventory["ORAN.O2IMS.Inventory"] { + <<InformationObjectClass>> + InfrastructureInventoryObject_ + } + class ORAN_O2IMS_Infrastructure["ORAN.O2IMS.Infrastructure"] { + <<InformationObjectClass>> + InfrastructureResourceType + InfrastructureResource + } + ORAN_O2IMS_Infrastructure --|> ORAN_O2IMS_Inventory + ORAN_O2IMS_Infrastructure --|> ORAN_O2IMS_Inventory + +``` + +UML class diagram showing inheritance. ORAN.O2IMS.Inventory (InformationObjectClass InfrastructureInventoryObject\_) is the superclass. ORAN.O2IMS.Infrastructure (InformationObjectClass InfrastructureResourceType and InformationObjectClass InfrastructureResource) are subclasses. Red arrows indicate inheritance from InfrastructureResourceType and InfrastructureResource to InfrastructureInventoryObject\_. + +**Figure 4.2.5.3.2.1-1 ORAN.O2ims.Infrastructure Inheritance** + +#### 4.2.5.4 Class Definitions + +##### 4.2.5.4.1 InfrastructureResourceType + +###### 4.2.5.4.1.1 Definition + +The InfrastructureResourceType represents a resource type in an O-Cloud. + +Infrastructure resource types provide the categorization of O-Cloud resources used to connect the O-Cloud resources and to build components of the Cluster namespace. The values for these types are used to build the configured inventory and enable an authorized consumer to track infrastructure resource changes over time. The O-Cloud provides a mechanism to discover the infrastructure resource types with respective operations on infrastructure resource types. + +The InfrastructureResourceType is a Specialized Object that derives from a Generalized Object, the InfrastructureInventoryObject. The InfrastructureResourceType inherits the attributes from the *InfrastructureInventoryObject\_* and allows it and all specializations of this class to be included in a change notification. + +###### 4.2.5.4.1.2 Attributes + +**Table 4.2.5.4.1.2-1 Attributes Properties for InfrastructureResourceType** + +| Attribute name | Data Type/Description | Properties | +|------------------------------|-------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| infrastructureResourceTypeid | <b>Data Type:</b> string<br><b>Description:</b> Identifier of the infrastructure resource type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string<br><b>Description:</b> Name of the | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False | + +| Attribute name | Data Type/Description | Properties | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | infrastructure resource type as identified by the cloud provider. | x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable description of the infrastructure resource type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by the vendor to extend the information provided about the Infrastructure Resource Type. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items:<br><br>AttributeValuePair | + +###### 4.2.5.4.1.3 Attribute constraints + +None. + +###### 4.2.5.4.1.4 State diagram + +None. + +##### 4.2.5.4.2 InfrastructureResource + +###### 4.2.5.4.2.1 Definition + +The InfrastructureResource is a Specialized Object that derives from a Generalized Object, the *InfrastructureInventoryObject*. The InfrastructureResource inherits the attributes from the *InfrastructureInventoryObject* and allows it and all specializations of this class to be included in a change notification. + +###### 4.2.5.4.2.2 Attributes + +**Table 4.2.5.4.1.2-1 Attributes Properties for InfrastructureResource** + +| Attribute name | Data Type/Description | Properties | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| infrastructureResourceId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of the resource. Locally unique within the scope of an O-Cloud instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| name | <b>Data Type:</b> string | x-support-qualifier: M<br>readOnly: True | + +| Attribute name | Data Type/Description | Properties | +|---------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <b>Description:</b> Human readable name of the infrastructure resource instance. | x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| description | <b>Data Type:</b> string<br><br><b>Description:</b> Human readable description of the resource pool. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| infrastructureResourceTypeId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of infrastructure resource type that this instance is a type of. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| linkedInfrastructureResourceIds | <b>Data Type:</b> array<br><br><b>Description:</b> List of infrastructure resource IDs that are used to realize this infrastructure resource instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: string | +| inventoryResourceIds | <b>Data Type:</b> array<br><br><b>Description:</b> List of inventory resource IDs that are used to realize this infrastructure resource instance. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>x-isOrdered: False<br>minItems: 1<br>uniqueItems: True<br>items: string | +| artifactResourceId | <b>Data Type:</b> string<br><br><b>Description:</b> Identifier of artifact resource Id that the instance was configured with. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>format: uuid | +| extensions | <b>Data Type:</b> array<br><br><b>Description:</b> These are unspecified (not standardized) properties (keys) which are tailored by the vendor to extend the information provided about the Resource Pool. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True<br>x-isOrdered: False<br>minItems: 0<br>uniqueItems: True<br>items: AttributeValuePair | + +###### 4.2.5.4.2.3 Attribute constraints + +None. + +###### 4.2.5.4.2.4 State diagram + +None. + +#### 4.2.5.4.3 Gateway + +###### 4.2.5.4.3.1 Definition + +The Gateway infrastructure resource is a specialization of the InfrastructureResource. As such in addition to the attributes below, all attributes of the InfrastructureResource are also a member of this class. + +NOTE 1: The present document version does not specify QoS related attributes/classes. + +NOTE 2: The present document version does not specify complete L2/L3 related attributes/classes associated to the Gateway. + +The Gateway is a Specialized Object that derives from a Generalized Object, the InfrastructureResource. The Gateway inherits the attributes from the InfrastructureResource. + +###### 4.2.5.4.3.2 Attributes + +**Table 4.2.5.4.3.2-1 Attributes Properties for Gateway** + +| Attribute name | Data Type/Description | Properties | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| tags | <b>Data Type:</b> array<br><b>Description:</b> The list of tags/labels on the Gateway resource. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: True<br>items:<br>AttributeValuePair | +| status | <b>Data Type:</b> string<br><b>Description:</b> The Gateway status. For instance, ACTIVE, DOWN, BUILD or ERROR. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False | +| connectedNetworks | <b>Data Type:</b> array<br><b>Description:</b> The list of port(s) to support one or multiple Site Networks termination. A port is a list of Gateway interfaceIPs e.g. IPv4 and IPv6 for a Site Network. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: True<br>items: Port | +| realizedBy | <b>Data Type:</b> string | x-support-qualifier: M | + +| Attribute name | Data Type/Description | Properties | +|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <b>Description:</b> Where this gateway is implemented/realized (e.g. SiteGW). | readOnly: True<br>x-isInvariant: True<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>format: UUID | +| attachedTo | <b>Data Type:</b> array<br><br><b>Description:</b> The list of port(s) to support one or multiple Attachment Circuits. A port is a list of Gateway interfaceIPs e.g. IPv4 and IPv6 for an Attachment Circuit. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: True<br>items: Port | + +###### 4.2.5.4.3.3 Attribute constraints + +None. + +###### 4.2.5.4.3.4 State diagram + +None. + +##### 4.2.5.4.4 SiteNetwork + +###### 4.2.5.4.4.1 Definition + +The SiteNetwork infrastructure resource is a specialization of the InfrastructureResource. As such in addition to the attributes below, all attributes of the InfrastructureResource are also a member of this class. + +NOTE: The present document version does not specify QoS related attributes/classes. + +The SiteNetwork is a Specialized Object that derives from a Generalized Object, the InfrastructureResource. The SiteNetwork inherits the attributes from the InfrastructureResource. + +###### 4.2.5.4.4.2 Attributes + +**Table 4.2.5.4.4.2-1 Attributes Properties for SiteNetwork** + +| Attribute name | Data Type/Description | Properties | +|----------------|---------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| tags | <b>Data Type:</b> array<br><br><b>Description:</b> The list of tags/labels on the SiteNetwork resource. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: True<br>items: AttributeValuePair | +| mtu | <b>Data Type:</b> integer<br><br><b>Description:</b> The maximum transmission unit (MTU) | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True | + +| Attribute name | Data Type/Description | Properties | +|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | value to address fragmentation. Minimum value is 68 for IPv4, and 1280 for IPv6. | x-stateChangeNotification: False<br>nullable: True | +| segmentation | <b>Data Type:</b> array<br><br><b>Description:</b> The list of segmentationElement(s) to support one or multiple segments where, a segmentationElement is a list of segmentationID (e.g. 100, 200) and segmentationType (e.g. flat, vlan, vxlan, or gre) | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 1<br>items:<br><br>SegmentationElement | +| realizedBy | <b>Data Type:</b> string<br><br><b>Description:</b> Where this network/segment is implemented/realized (e.g. SiteNWFabric). | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| shared | <b>Data Type:</b> Boolean<br><br><b>Description:</b> Indicates if the network is shared (True). | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | +| status | <b>Data Type:</b> string<br><br><b>Description:</b> The SiteNetwork status. For instance, ACTIVE, DOWN, BUILD or ERROR. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: False | +| subnets | <b>Data Type:</b> array<br><br><b>Description:</b> The list of associated subnets. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 1<br>items:<br><br>KeyValuePair | +| externalSiteNW | <b>Data Type:</b> Boolean<br><br><b>Description:</b> Indicates if the network is also external (True) or not (False) to the O-Cloud Site. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: True<br>default: False | + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| attachedTo | <b>Data Type:</b> array<br><br><b>Description:</b> The list of port(s) to support one or multiple Attachment Circuits. A port is a list of interfaceIPs e.g. IPv4 and IPv6 for an Attachment Circuit. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: True<br>nullable: True<br>items: Port | + +###### 4.2.5.4.4.3 Attribute constraints + +None. + +###### 4.2.5.4.4.4 State diagram + +None. + +##### 4.2.5.4.5 AttachmentCircuit + +###### 4.2.5.4.5.1 Definition + +The AttachmentCircuit infrastructure resource is a specialization of the InfrastructureResource. As such in addition to the attributes below, all attributes of the InfrastructureResource are also a member of this class. + +NOTE: The present document version does not specify QoS related attributes/classes. + +The AttachmentCircuit is a Specialized Object that derives from a Generalized Object, the InfrastructureResource. The AttachmentCircuit inherits the attributes from the InfrastructureResource. + +###### 4.2.5.4.5.2 Attributes + +**Table 4.2.5.4.5.2-1 Attributes Properties for AttachmentCircuit** + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| tags | <b>Data Type:</b> array<br><br><b>Description:</b> The list of tags/labels on the Gateway resource. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: True<br>items: AttributeValuePair | +| segmentation | <b>Data Type:</b> array<br><br><b>Description:</b> The list of segmentationElement(s) to support one or multiple segments where, a segmentationElement is a list of segmentationID (e.g. 100, 200) and segmentationType | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 1<br>items: SegmentationElement | + +| Attribute name | Data Type/Description | Properties | +|----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| | (e.g. flat, vlan, vxlan, or gre) | | +| bearer | <b>Data Type:</b> string<br><br><b>Description:</b> A physical or logical link that establishes connectivity between the O-Cloud Site and external networks. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False | + +###### 4.2.5.4.5.3 Attribute constraints + +None. + +###### 4.2.5.4.5.4 State diagram + +None. + +##### 4.2.5.4.6 Port <<dataType>> + +##### 4.2.5.4.6.1 Definition + +The Port is a list of network addresses (IPv4, IPv6, or IPv4 and IPv6) which a network device is connected to. + +##### 4.2.5.4.6.2 Attributes + +**Table 4.2.5.4.6.2-1 Attributes Properties for Port** + +| Attribute name | Data Type/Description | Properties | +|----------------|--------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| endPoints | <b>Data Type:</b> array<br><br><b>Description:</b> The list of addresses to support one or multiple network connections. | x-support-qualifier: M<br>readOnly: True<br>x-isInvariant: False<br>x-inventoryNotification: True<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 1<br>items: NetworkAddress | + +##### 4.2.5.4.6.3 Attribute constraints + +None. + +##### 4.2.5.4.6.4 State diagram + +None. + +#### 4.2.5.4.7 SegmentationElement <<dataType>> + +##### 4.2.5.4.7.1 Definition + +The SegmentationElement represents one segment of a SiteNetwork. A SiteNetwork may have more than one segment. + +##### 4.2.5.4.7.2 Attributes + +**Table 4.2.5.4.7.2-1 Attributes Properties for SegmentationElement** + +| Attribute name | Data Type/Description | Properties | +|------------------|--------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| segmentationType | <b>Data Type:</b> string<br><br><b>Description:</b> The description of the type of segmentation. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False | +| Segments | <b>Data Type:</b> array<br><br><b>Description:</b> list of segmentIds for a given SiteNetwork segment. | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: False<br>minItems: 1<br>items: string | + +##### 4.2.5.4.7.3 Attribute constraints + +None. + +##### 4.2.5.4.7.4 State diagram + +None. + +#### 4.2.5.4.8 NetworkAddress <<dataType>> + +##### 4.2.5.4.8.1 Definition + +The NetworkAddress is an IP address (IPv4, IPv6, or IPv4 & IPv6) which identifies a network address. + +##### 4.2.5.4.8.2 Attributes + +**Table 4.2.5.4.8.2-1 Attributes Properties for NetworkAddress** + +| Attribute name | Data Type/Description | Properties | +|----------------|-------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------| +| ipv4Addr | <b>Data Type:</b> Ipv4Addr<br><br><b>Description:</b> IPv4 address as defined in 3GPP TS 28.623 | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | +| ipv6Addr | <b>Data Type:</b> Ipv6Addr<br><br><b>Description:</b> IPv6 address as defined in 3GPP TS 28.623 | x-support-qualifier: M<br>x-isInvariant: False<br>x-inventoryNotification: False<br>x-stateChangeNotification: False<br>nullable: True | + +## 4.2.5.4.8.3 + +## Attribute constraints + +**Table 4.2.5.4.8.3-1 Attributes Constraints for EndPoint** + +| Name | Definition | +|----------------------------|------------------------------------------------------------------------------------------------------------------| +| ATLEAST_ONE_ADDRESS_EXISTS | Condition: if ipv4Addr exists then ipv6Addr is optional. Likewise, if ipv6Addr exists then ipv4Addr is optional. | + +## 4.2.5.4.8.4 + +## State diagram + +None. + +--- + +## Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.03.21 | 00.01.00 | Create initial O-RAN version, from template with modifications for 3GPP TS 32.160 | +| 2023.04.28 | 00.01.01 | Modified Scope, Introduction, References, and Annex Formatting CR: ATT-2023.03.15-WG6-CR-001-O2IM Introduction and Scope Changes - v02. | +| 2023.04.28 | 00.01.02 | Modified Section 4 Outline with examples CR: ATT-2023.04.04-CR-003-O2IM Section 4 new Outline-v04. | +| 2023.06.02 | 00.01.03 | Incorporated the following CRs:<br>ATT-2023.05.02-WG6-CR-004-ORIM Template Cleanup-v01<br>ATT-2023.05.03-WG6-CR-005-O2IM IMS Diagrams-v03<br>ATT-2023.05.23-WG6-CR-006-O2IM Imported and Associated Entities-v03<br>ATT-2023.05.23-WG6-CR-007-O2IM Fault Monitoring-v04 | +| 2023.07.10 | 00.02.00 | Initial internal release based on the current O2IMS Specification.<br><br>Incorporated the following CRs:<br>ATT-2023.05.30-WG6-CR-008-O2IM Infrastructure Inventory-v05<br>ATT-2023.05.23-WG6-CR-009-O2IM LCM-v03<br>ATT-2023.05.31-WG6-CR-010-O2IM Performance Store-v03<br>ATT-2023.05.31-WG6-CR-011-O2IM Performance Job-v04<br>ATT-2023.06.01-WG6-CR-012-O2IM Performance Subscription-v04<br>ATT-2023.06.01-WG6-CR-013-O2IM Performance Report-v03 | +| 2024.03.12 | 01.00.00 | Initial release<br><br>Incorporated the following CRs:<br>ATT-2024.03.01-WG6-CR-019-O2IM CR Merge Corrections-v03<br>DELL.AO-2023.09.26-WG6-CR-0002-O2IM_Site_v07<br>ATT-2024.01.26-WG6-CR-017-O2IM Namespace alignment-V02<br>ATT-2024.01.26-WG6-CR-018-O2IM Measurement Job Corrections-V04<br>ATT-2023.09.15-WG6-CR-016-O2IM Deferred Comment Corrections-V04<br>DELL.AO-2023.02.21-WG6-CR-0001-O2IM Extensions to infrastructure service objects-v03<br>ATT-2023.08.25-WG6-CR-015-O2IM New PM Use Case Support-v03<br>ATT-2023.06.01-WG6-CR-014-O2IM New Alarm Use Case Support-v06<br>Editorial, missing clauses for new section 4.3.3.5.3, 4.3.3.5.4 | +| 2024.07.01 | 01.00.04 | Incorporated the following CRs:<br>ERI.AO-2024.04.09-WG6-CR-0029-Namespaces-Updates-v03<br>ATT-2024.04.15-WG6-CR-0020-New Namespace Skeletons-v03<br>ATT-2024.04.23-CR-021-Remove Performance Measurement Subscription-v01<br>ERI.AO-2023.07.25-WG6-CR-0024-OCLOUD_Networking_Information_Model-v21 | +| 2024.07.05 | 01.00.05 | Incorporated the following CRs:<br>ATT-2024.05.28-WG6-CR-0022-Performance Subscription Correction-v02<br>ATT-2024.05.28-WG6-CR-0023-log Query Enhancements-v05 | +| 2024.07.19 | 02.00.00 | Incorporated Release review Comments | +| 2024.11.12 | 03.00.00 | Incorporated the following CRs:<br>DELL.AO-2024.08.27-WG6-CR-0010-O2IM_DictionaryId_v01<br>NOK.AO-2024.09.10-WG6-CR0131-GenSpclResource_Guidelines_v01.01<br>ATT-2024.07.30-WG6-CR-0024-Provisioning Relationship Modeling-v06<br>ATT.AO-2024.07.31-WG6-CR-0025-Networking Infrastructure Attribution-v09<br>ATT.AO-2024.09.11-WG6-CR-0026-Infrastructure Specialized Classes-v09<br>ATT-2024.09.11-WG6-CR-0027-PM Job Writeable Extensions-v02<br>ATT-2024.09.11-WG6-CR-0028-InfrastructureInventoryObjectName Correction-v03<br>ATT-2024.10.02-WG6-CR-0030-Cluster Classes and Attribution-v05<br>ATT-2024.10.02-WG6-CR-0031-Artifact Classes and Attribution-v04<br>ATT-2024.10.02-WG6-CR-0032-Provisioning Classes and Attribution-v08<br>ATT.AO-2024.10.15-WG6-CR-0033-3GPP Alignment to Release 18-v02<br>The following Editorial changes were made to make the document cohesive<br>Boiler plate text required for the Infrastructure Namespace which was not included in ATT-CR-0025 or ATT-CR-0026. This included the clause 4.2.5 itself and clauses 4.2.5.1, 4.2.5.2, and 4.2.5.3 | + diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/561bdf2b5a80d068c74b413d0214e94f_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/561bdf2b5a80d068c74b413d0214e94f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1d234f5d6975b44d4a53620cd6439e1e0fb3dc7 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/561bdf2b5a80d068c74b413d0214e94f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:300b9eb77c3a7d71beac91facc82f89c9d09f01db8700a6302a95489dd1d437c +size 3932 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/73ebaea5ae8c8c646d8cd9aa0df86a89_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/73ebaea5ae8c8c646d8cd9aa0df86a89_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..caf02fa3fc14a00c89afebe1e80e5de0f69f0271 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/73ebaea5ae8c8c646d8cd9aa0df86a89_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f29f5ac02e9a8d6cf140ad10f612adaf7e14ff6e74ba938338599ac76fc34dac +size 4564 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/9ab9b810e41cb455cb61ae7a3b955547_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/9ab9b810e41cb455cb61ae7a3b955547_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e440987be6416572b6a15f5171cffd985abcd28f --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/9ab9b810e41cb455cb61ae7a3b955547_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a761becbecc98e7a7c9caf458a831a78fe1dfc3e6b3a41c3201fdf48159a2a2f +size 4463 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/9d0e6686f5161fe7bef6031a279a21c7_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/9d0e6686f5161fe7bef6031a279a21c7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..08a9c509da7e591b85ce9c11c7659f729776badc --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/9d0e6686f5161fe7bef6031a279a21c7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e51e29a8c647908fe9f48f56b660f7378772dafa9202a271bcb2032f560fafe1 +size 4531 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/a794ba4bcc01ce28fcce5ddc87e04cc7_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/a794ba4bcc01ce28fcce5ddc87e04cc7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2e5d80234f913a745d989fc39cc84d2a49d374d9 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/a794ba4bcc01ce28fcce5ddc87e04cc7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d1ef3125949a6ba0175b13e95dbf87b00adf49b418f757a482fe28a7ffc2abd6 +size 25841 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/d72b945aac5d8bdfda2b76b71be1c704_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/d72b945aac5d8bdfda2b76b71be1c704_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d73ac8b8be38faf362b1eaa59fff1f3f167364fb --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/d72b945aac5d8bdfda2b76b71be1c704_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3276e59412020445a9dbac9cf2ede064a279427afdcaa0dcf94fa0620d916726 +size 4546 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/fa76c1db0441bd3a7abeb5c67ea32863_img.jpg b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/fa76c1db0441bd3a7abeb5c67ea32863_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1b906fb15b9a52af22818f2ebe78b20e29e87fd --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/fa76c1db0441bd3a7abeb5c67ea32863_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8d6883fcfaeb9decd334720a9393bec684f997d9b55f6a6570257cec64f090dd +size 64011 diff --git a/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/raw.md b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..900b2b926e2d0f52db1e280e9dffcbebb8c9c5ce --- /dev/null +++ b/marked/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01/raw.md @@ -0,0 +1,1730 @@ + + +# **O-RAN Working Group 6****O-Cloud Interface Conformance Test Specification** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|---------------------------------------------------------------------------------------------------------------------|----| +| List of Figures..... | 4 | +| List of tables ..... | 4 | +| Foreword..... | 5 | +| Modal verbs terminology ..... | 5 | +| Introduction ..... | 5 | +| 1 Scope..... | 5 | +| 1.1 Test Requirement Status ..... | 5 | +| 2 References ..... | 7 | +| 2.1 Normative references ..... | 7 | +| 2.2 Informative references ..... | 8 | +| 3 Definition of terms, symbols and abbreviations..... | 8 | +| 3.1 Terms ..... | 8 | +| 3.2 Abbreviations..... | 9 | +| 4 Testing methodology..... | 10 | +| 4.1 System under test..... | 10 | +| 4.2 Test method ..... | 11 | +| 4.2.1 Testing procedure..... | 11 | +| 4.2.2 Statistics and analysis of key indicators ..... | 11 | +| 5 O-Cloud Notification API Test ..... | 11 | +| 5.1 General..... | 11 | +| 5.2 Test Configuration..... | 11 | +| 5.2.1 System Under Test requirements ..... | 11 | +| 5.2.2 Test Tools and Simulators capabilities..... | 12 | +| 5.3 Test cases ..... | 13 | +| 5.3.1 Create a subscription resource..... | 13 | +| 5.3.2 Get a list of subscription resources..... | 14 | +| 5.3.3 Get Detail of individual subscription resource ..... | 14 | +| 5.3.4 Delete individual subscription resources..... | 15 | +| 5.3.5 Event notification and Notification sanity check ..... | 16 | +| 5.3.6 Event pull status notification..... | 17 | +| 6 AAL API Test ..... | 17 | +| 7 O2 Interface Test..... | 18 | +| 7.1 General..... | 18 | +| 7.2 Test Configuration ..... | 18 | +| 7.2.1 System Under Test requirements ..... | 18 | +| 7.2.2 Test Tools capabilities..... | 18 | +| 7.3 O2 IMS Test ..... | 19 | +| 7.3.1 O-Cloud succeeds to deliver O-Cloud Available Notification to SMO. .... | 19 | +| 7.3.2 SMO succeeds to query inventory with correct token..... | 19 | +| 7.3.3 SMO succeeds to subscribe for O2ims inventory changes notification and succeeds to receive notifications..... | 22 | +| 7.3.4 SMO succeeds to create alarmSubscription, receive alarm notification, and query alarm list. .... | 23 | +| 7.3.5 Verify general aspects of O2ims API..... | 24 | +| 7.3.6 SMO gets 405 while sending O2ims APIs with unsupported method. .... | 26 | +| 7.3.7 SMO gets 400 while issuing O2ims APIs with incorrect data. .... | 27 | +| 7.3.8 SMO gets security error response while issuing APIs with incorrect token..... | 29 | +| 7.3.9 SMO gets client error response while issuing requests with incorrect APIs ..... | 30 | + +| | | | +|--------------------------------------------------------------------------------|---------------------------------------------------------------------------------------|----| +| 7.3.10 | SMO succeeds to get O2dms (in Kubernetes native API Profile) access information. .... | 30 | +| 7.3.11 | SMO gets 400 when issuing APIs with junk/unsupported data. .... | 31 | +| 7.3.12 | SMO gets 404 when issuing APIs with wrong data. .... | 32 | +| 7.4 | O2 DMS Test..... | 33 | +| 7.4.1 | General..... | 33 | +| 7.4.2 | O2 DMS ETSI NFV Profile Test ..... | 33 | +| Annex A (normative): Checklist for Cases applies to O-Cloud technologies ..... | | 45 | +| A.1 | O-Cloud technologies ..... | 45 | +| A.2 | Cloud Technology Applicability of test cases ..... | 45 | +| A.3 | Case Traceability ..... | 50 | + +# --- List of Figures + +| | | +|-------------------------------------------------------------------|----| +| Figure 4.1-2: The overview of O-Cloud Interface test..... | 10 | +| Figure 5.2-1: Configuration of O-Cloud Notification API test..... | 12 | + +# --- List of tables + +| | | +|-------------------------------------------------------------------------------------------|----| +| Table 1.1-1: List of O-RAN O-Cloud Notification API Test Scenarios and Status ..... | 6 | +| Table 1.1-2: List of O-RAN O-Cloud O2ims Test Scenarios and Status ..... | 6 | +| Table 1.1-3: List of O-RAN O-Cloud O2dms ETSI NFV profile Test Scenarios and Status ..... | 7 | +| Table A.2-1: O-Cloud IOT and corresponding Interfaces/APIs, DUTs and SUTs..... | 45 | +| Table A.3-1: O-Cloud IOT and corresponding Interfaces/APIs, DUTs and SUTs ..... | 50 | + +# --- Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +--- + +# Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Introduction + +This document specifies the O-Cloud interface test specification to guide O-Cloud products conforming to the O-RAN specifications, including the O-Cloud Notification API, AAL API and O2 interface. + +--- + +# 1 Scope + +The present document specifies a test specification for test and validation of the O-Cloud interfaces/APIs. This document will specify the testing methodology and test cases, for O-Cloud interfaces/APIs including O-Cloud Notification API, AAL API and O2 interface. + +## 1.1 Test Requirement Status + +The purpose of section is to clarify which of the test cases provided in this specification shall be passed to verify a particular O-Cloud interfaces or API to comply with the O-Cloud specification. + +The following tables list each test in this conformance specification and requirement of the test as MANDATORY or CONDITIONAL MANDATORY. MANDATORY means the function/feature/capability under test shall be supported in relevant O-Cloud interface specification. OPTIONAL means the function/feature/capability under test may or may not be supported in relevant O-Cloud interface specification. The status of test if conditional (mandatory, optional), if the support of function/feature/capability under test depends on other items defined in relevant O-Cloud interface specification. + +Table 1.1-1 lists the test scenarios and requirement regarding the O-Cloud Notification API. + +**Table 4.2.1-1: List of O-RAN O-Cloud Notification API Test Scenarios and Status** + +| Test Number | Test Requirement | Test Description | +|-------------|-----------------------|---------------------------------------------------------| +| 5.3.1 | CONDITIONAL MANDATORY | Create a subscription for event notifications | +| 5.3.2 | CONDITIONAL MANDATORY | Query the list of subscriptions for event notifications | +| 5.3.3 | CONDITIONAL MANDATORY | Query the detail of a subscription | +| 5.3.4 | CONDITIONAL MANDATORY | Delete a subscription of event notifications | +| 5.3.5 | CONDITIONAL MANDATORY | Send event notification and sanity check | +| 5.3.6 | CONDITIONAL MANDATORY | Pull event information | + +Regarding the O-Cloud Notification API test scenarios, tests 5.3.1, 5.3.2, 5.3.3, 5.3.4 and 5.3.5 are for push mode notification only, while test 5.3.6 is for pull mode. Either mode shall be tested to verify an implementation of the O-Cloud Notification API complies with the O-Cloud specification. + +Table 1.1-2 lists the test scenarios and requirements regarding the O-Cloud O2ims. + +**Table 4.2.1-2: List of O-RAN O-Cloud O2ims Test Scenarios and Status** + +| Test Number | Test Requirement | Test Description | +|-------------|------------------|-----------------------------------------------------------------------------------| +| 7.3.1 | MANDATORY | Available Notification | +| 7.3.2 | MANDATORY | Query inventory with correct token<br>(positive case) | +| 7.3.3 | MANDATORY | Subscribe and receive O2ims inventory changes notification<br>(positive case) | +| 7.3.4 | MANDATORY | Create, query alarmSubscription and receive alarm notification<br>(positive case) | +| 7.3.5 | MANDATORY | Deliver O-Cloud Available notification(general aspects) | +| 7.3.6 | MANDATORY | Requests with unsupported method to O2ims APIs<br>(negative case) | +| 7.3.7 | MANDATORY | Requests with incorrect data to O2ims APIs<br>(negative case) | +| 7.3.8 | MANDATORY | Requests with incorrect token to O2ims APIs<br>(negative case) | +| 7.3.9 | MANDATORY | Requests with incorrect APIs to O2ims APIs<br>(negative case) | + +| Test Number | Test Requirement | Test Description | +|-------------|------------------|------------------------------------------------------------------------------------| +| 7.3.10 | MANDATORY | Get O2dms (in Kubernetes native API Profile) access information<br>(positive case) | +| 7.3.11 | MANDATORY | Requests with junk/unsupported data to O2ims APIs<br>(negative case) | +| 7.3.12 | MANDATORY | Requests with wrong data to O2ims APIs<br>(negative case) | + +Table 1.1-3 lists the test scenarios and requirements regarding the O-Cloud O2dms ETSI NFV profile. + +**Table 4.2.1-3: List of O-RAN O-Cloud O2dms ETSI NFV profile Test Scenarios and Status** + +| Test Number | Test Requirement | Test Description | +|-------------|------------------|----------------------------------------------------| +| 7.4.2.3 | MANDATORY | Service operations (lifecycle, fault, performance) | +| 7.4.2.4 | MANDATORY | O2dms_DeploymentLifecycle Service API | +| 7.4.2.5 | MANDATORY | O2dms_Fault Service API | +| 7.4.2.6 | MANDATORY | Performance Service API | + +NOTE: The present document version does not list the test scenarios and requirements regarding the O-Cloud O2dms Kubernetes profile, as corresponding test descriptions are not available in from the referenced documentation. + +# 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN.WG6.ORCH-USE-CASES: “Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN”. +- [2] O-RAN.WG6.O-Cloud Notification API-v02.01: “O-Cloud Notification API Specification for Event Consumers”. + +- [3] O-RAN. WG4.CUS.0-v08.00: “O-RAN Working Group 4 (Open Fronthaul Interfaces WG) Control, User and Synchronization Plane Specification”. +- [4] O-RAN. WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE-v08.00: "O-RAN Working Group 6; O2dms Interface Specification: Profile based on ETSI NFV Protocol and Data Models" +- [5] ETSI GS NFV-SOL 003 V4.5.1: "Network Functions Virtualisation (NFV) Release 4; Protocols and Data Models; RESTful protocols specification for the Or-Vnfm Reference Point". +- [6] ETSI GS NFV-TST 010 V4.5.1: “Network Functions Virtualisation (NFV) Release 4; Testing; API Conformance Testing Specification” +- [7] O-RAN. WG6.O2IMS-INTERFACE: “O-RAN Working Group 6 O2ims Interface Specification” +- [8] NFV API Conformance Test Specification: <https://forge.etsi.org/rep/nfv/api-tests/-/wikis/NFV-API-Conformance-Test-Specification> +- [9] O-RAN.WG1.OAD-R003-v11.00: “O-RAN Work Group 1 (Use Cases and Overall Architecture) O-RAN Architecture Description” + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905, Vocabulary for 3GPP Specifications. +- [i.2] O-RAN.WG6 CAD: “Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN”. + +# --- 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [i.1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [i.1]. + +**O-Cloud** This refers to a collection of O-Cloud Resource Pools at one or more location and the software to manage Nodes and Deployments hosted on them. An O-Cloud will include functionality to support both Deployment-plane and Management services. The O-Cloud provides a single logical reference point for all O-Cloud Resource Pools within the O-Cloud boundary. + +- O-DU** O-RAN Distributed Unit—a logical node hosting RLC/MAC/High-PHY layers based on a lower layer functional split. +- O-RU** O-RAN Radio Unit—a logical node hosting Low-PHY layer and RF processing based on a lower layer functional split. This is similar to 3GPP’s “TRP” or “RRH”, but more specific in including the Low-PHY layer (FFT/iFFT, PRACH extraction). + +## 3.2 Abbreviations + +For the purposes of this document, the abbreviations given in 3GPP TR 21.905 [i.1] and the following apply. + +An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in 3GPP TR 21.905 [i.1]. + +| | | +|---------|------------------------------------------| +| 3GPP | Third Generation Partnership Project | +| AAL | Acceleration Abstraction Layer | +| API | Application Programming Interface | +| CNF | Cloud-Native Network Function | +| CPU | Central Processing Unit | +| EC | Event Producer | +| EP | Event Consumer | +| FFT | Fast Fourier Transform | +| HW | Hardware | +| IMS | Infrastructure Management Services | +| IRQ | Interrupt ReQuest | +| NF | Network Function | +| O-Cloud | O-RAN Cloud Platform | +| O-CU | O-RAN Centralized Unit | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| OS | Operating System | +| RAN | Radio Access Network | +| RIC | RAN Intelligent Controller | +| SMO | Service Management and Orchestration | +| SR-IOV | Single Root Input/ Output Virtualization | + +| | | +|-------------------------------------------------------------------------------------------------------------|--------------------------------------------| +| <img alt="O-RAN ALLIANCE Logo" data-bbox="161 129 365 197" src="9ab9b810e41cb455cb61ae7a3b955547_img.jpg"/> | O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01 | +|-------------------------------------------------------------------------------------------------------------|--------------------------------------------| + +| | | +|------|------------------------------| +| SUT | System Under Test | +| TS | Technical Specification | +| vCPU | Virtual CPU | +| VM | Virtual Machine | +| VNF | Virtualized Network Function | +| WG | Working Group | + +# 4 Testing methodology + +## 4.1 System under test + +SUT refers to 3GPP TR [i.2] and O-RAN.WG1.OAD [9]. The main architecture components and interfaces/APIs for the O-Cloud platform software can be found in Figure 4.1-1. + +![Figure 4.1-1: The overview of O-Cloud Interface test](fa76c1db0441bd3a7abeb5c67ea32863_img.jpg) + +Figure 4.1-1: The overview of O-Cloud Interface test + +Detailed description of Figure 4.1-1: +The diagram illustrates the O-Cloud Interface test architecture. At the top is the 'Service Management and Orchestration Framework' (SMO) containing 'Network Function Orchestrator (NFO)', 'OAM Function', 'Federated O-Cloud Orchestration and Management (FOCOM)', and 'Non-RT RIC'. +Below the SMO is the 'O-RAN Network Functions' block containing 'Near-RT RIC' and 'O-RU'. +At the bottom is the 'O-Cloud' block containing 'AAL' (with 'AAL implementation' and 'AAL Interface'), and 'O2' (with 'IMS' and 'DMS'). +Interfaces shown include: +- O2 interface connecting SMO to O-Cloud (IMS/DMS). +- A1 and O1 interfaces connecting SMO to O-RAN Network Functions. +- Open Fronthaul M-Plane connecting SMO to O-RU. +- O-Cloud Notification interface connecting O-RAN Network Functions to O-Cloud. +- NG interface connecting O-RAN Network Functions to NG-Core. +An external system provides enrichment data to the SMO. +A 'Test Function' block is shown on the right, interacting with the O2 interface of the O-Cloud. +A Legend on the right defines: +- Purple line: O-RAN Defined Interface +- Orange line: 3GPP Defined Interface +- Black line: Interface out of scope for O-RAN + +Figure 4.1-1: The overview of O-Cloud Interface test + +For the Cloud platform, different technologies may be used by cloud vendors, [i.2] such as: + +- VMs only, +- Containers only, +- Containers in VMs, +- both VMs and Containers, OR +- other new technologies + +so, the O-Cloud should be tested exactly based on the technology used. + +Cases applied to each technology are listed in the Annex A. + +SUT is identified by an implementation of the function under test producing or consuming the API Under Test (AUT) e.g. in the case of the O2DMS interface the function under test is O-Cloud implementation. + +| | | +|---------------------------------------------------------------------------------------------------------------------------|----| +| © 2025 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. | 10 | +|---------------------------------------------------------------------------------------------------------------------------|----| + +The function is tested in isolation with respect to SMO, O-RAN Network Functions and O-Cloud, to guarantee that the outcomes of the conformance tests are not result of interoperability issues with other components. + +## 4.2 Test method + +### 4.2.1 Testing procedure + +The SUT and the test tool are set up and connected to the device in strict accordance with the preset conditions of each test case in the specification, and the test steps in the test case are performed step by step. Tester should record in detail the important test information during and after the test and compare and analyze with the expected results. Each test case is independent of each other. + +### 4.2.2 Statistics and analysis of key indicators + +The test is performed based on the preset conditions and procedure in the test case. The expected test result is used as the standard to determine whether the test succeeds. If the test result is consistent with the expected result, the test is regarded as passing. Tester may record test result, such as throughput, latency, and device volume. + +# 5 O-Cloud Notification API Test + +## 5.1 General + +O-Cloud provides a Notification Framework; it acts as the event producer and exposes APIs to event consumers. The APIs enable the consumers to subscribe event notifications, delete subscriptions, get a list of subscriptions and detail of a subscription, notification to event consumers by pull or push mode. + +Event consumers can be applications (e.g. O-DU). + +Refer to O-RAN.WG6.O-Cloud Notification API [2], this section describes the test cases for O-Cloud Notification APIs. + +## 5.2 Test Configuration + +### 5.2.1 System Under Test requirements + +The SUT for the O-Cloud Notification API is the O-Cloud, which provides an O-Cloud notification event producer(EP). This allows Event consumers (EC, such as O-DU or CNF) to subscribe event notifications, delete subscriptions, get a list of subscriptions or detail of a subscription, and receive events/status from cloud infrastructures. Notification to event consumers by pull or push mode. + +The test functions are the tools which simulate the workloads (applications running in the cloud) or other entities out of the cloud interested in the events. + +![Figure 5.2-1: Configuration of O-Cloud Notification API test. The diagram shows a large blue rounded rectangle labeled 'O-Cloud' containing a white rounded rectangle labeled 'Notification Framework'. Above the O-Cloud, there is a stack of three grey rectangles labeled 'Test Function'. A dashed blue arrow labeled 'Notification Push/Pull' points from the Test Function stack down to the Notification Framework. A solid black arrow labeled 'Queries/Subscribes' points from the Notification Framework up to the Test Function stack. Below the O-Cloud, there are two small grey rectangles: one labeled 'SUT' (System Under Test) on the left and one labeled 'Test Function' on the right.](a794ba4bcc01ce28fcce5ddc87e04cc7_img.jpg) + +Figure 5.2-1: Configuration of O-Cloud Notification API test. The diagram shows a large blue rounded rectangle labeled 'O-Cloud' containing a white rounded rectangle labeled 'Notification Framework'. Above the O-Cloud, there is a stack of three grey rectangles labeled 'Test Function'. A dashed blue arrow labeled 'Notification Push/Pull' points from the Test Function stack down to the Notification Framework. A solid black arrow labeled 'Queries/Subscribes' points from the Notification Framework up to the Test Function stack. Below the O-Cloud, there are two small grey rectangles: one labeled 'SUT' (System Under Test) on the left and one labeled 'Test Function' on the right. + +**Figure 5.2-1: Configuration of O-Cloud Notification API test** + +### 5.2.2 Test Tools and Simulators capabilities + +A summary of the recommended testing tools and simulators for functional testing is shown as following. + +**Postman:** Postman is an interface testing tool. Postman is equivalent to a client, which can simulate various HTTP requests initiated by users, send the request data to the server, and obtain the corresponding response results, so as to verify whether the result data in the response matches the expected value. It is mainly used to simulate various HTTP requests (e.g. Get/POST/delete/put). The difference between Postman and browsers is that some browsers can't output Json format, while Postman is more intuitive about the results returned by the interface. In the following test, Postman act as the event consumer, and it can also be configured to received notification from the event producer. + +**Curl:** Curl is a command-line tool for transferring data specified with URL syntax. It can be used as the event consumer. + +**HTTPie:** HTTPie is a command-line HTTP client with an intuitive interface, support for JSON, syntax highlighting, download functionality (like wGET), plugin support, and more. HTTPie consists of a simple HTTP command that is easy to debug and interact with HTTP servers, RESTful apis, and Web Services. It can be used as the event consumer. + +## 5.3 Test cases + +### 5.3.1 Create a subscription resource + +#### 5.3.1.1 Test Purpose + +The purpose of this test case is to verify the capability to create a subscription for event notifications. + +This test case is conditional, if the SUT (O-Cloud) claims to support O-Cloud Notification API, it shall support at least pull mode notification or push mode; for push mode, this case applies. + +#### 5.3.1.2 Test Entrance Criteria + +- 1) The SUT supports the O-Cloud Event Notification Create subscription request. +- 2) The Test Simulator has the functionality to initiate Create subscription request. + +#### 5.3.1.3 Initial conditions + +- 1) The simulator (acting as a workload) has started. +- 2) The SUT (O-Cloud) has the Notification service ready and available to receive subscription request from the Test Simulator. + +#### 5.3.1.4 Procedure + +Step 1. Send an HTTP2 POST request from Test Simulator to SUT with the correct URI format as specified in O-RAN.WG6.O-Cloud Notification API [2] clause 4.1.2 containing the JSON format Subscriptioninfo as specified in O-RAN.WG6.O-Cloud Notification API [2] clause 7.1.1.1 as the message body. The message shall include an event notification request, endpointUri and ResourceAddress. + +Step 2. At the Test Simulator the received HTTP2 response is recorded. + +#### 5.3.1.5 Expected Results + +The test is considered passed if + +- 1) The return code is “201 OK”, with Response message body content that contains a Subscriptioninfo, when the subscription request is correct and processed by the EP. +- 2) The return code is “400 Bad request”, without message body, when the subscription request is not correct. +- 3) The return code is “404 Not found”, without message body, when the subscription resource is not available. +- 4) The return code is “409 Conflict”, without message body, when the subscription resource already exists. + +### 5.3.2 Get a list of subscription resources + +#### 5.3.2.1 Test Purpose + +The purpose of this test case is to verify the capability to query the list of subscriptions for event notifications from event consumers. + +This test case is conditional: if the SUT (O-Cloud) claims to support O-Cloud Notification API, it shall support at least pull mode notification or push mode; for push mode, this case applies. + +#### 5.3.2.2 Test Entrance Criteria + +- 1) The SUT supports the O-Cloud Event Notification subscription resources create and query requests. +- 2) The Test Simulator has the functionality to initiate Query subscription resources request. + +#### 5.3.2.3 Initial conditions + +- 1) The simulator (acting as a workload) has started. +- 2) The SUT (O-Cloud) has the Notification service ready and available to receive subscription resources query request from the Test Simulator. + +#### 5.3.2.4 Procedure + +Step 1. Send an HTTP2 GET request from Test Simulator to SUT with the correct URI format as specified in O-RAN.WG6.O-Cloud Notification API [2] clause 4.1.2. + +Step 2. At the Test Simulator the received HTTP2 response is recorded. + +#### 5.3.2.5 Expected Results + +The test is considered passed if + +- 1) The return code is “200 OK”, with Response message body content containing an array of Subscriptioninfo. +- 2) The return code is “400 Bad request”, without message body, when the query request is not correct. + +### 5.3.3 Get Detail of individual subscription resource + +#### 5.3.3.1 Test Purpose + +The purpose of this test case is to verify the capability to query the detail of a subscription from event consumers. + +This test case is conditional: if the SUT (O-Cloud) claims to support O-Cloud Notification API, it shall support at least pull mode notification or push mode; for push mode, this case applies. + +#### 5.3.3.2 Test Entrance Criteria + +- 1) The SUT supports the O-Cloud Event Notification subscription resources create (Chapter 7.3) and query request, and supports query to an individual subscription resource. +- 2) The Test Simulator has the functionality to initiate subscription query request. + +#### 5.3.3.3 Initial conditions + +- 1) The simulator (acting as a workload) has started. +- 2) The SUT (O-Cloud) has the Notification service ready and available to receive query request from the Test Simulator. + +#### 5.3.3.4 Procedure + +Step 1. Send an HTTP2 POST request from Test Simulator to SUT with the correct URI format as specified in O-RAN.WG6.O-Cloud Notification API [2] clause 4.1.3. + +Step 2. At the Test Simulator the received HTTP2 response is recorded. + +#### 5.3.3.5 Expected Results + +The test is considered passed if + +- 1) The return code is “200 OK”, with Response message body content containing a Subscriptioninfo. +- 2) The return code is “404 Not found”, without message body, when the subscription resource is not available (not created). + +### 5.3.4 Delete individual subscription resources + +#### 5.3.4.1 Test Purpose + +The purpose of this test case is to verify the capability to delete a subscription of event notifications. + +This test case is conditional: if the SUT (O-Cloud) claims to support O-Cloud Notification API, it shall support at least pull mode notification or push mode; for push mode, this case applies. + +#### 5.3.4.2 Test Entrance Criteria + +- 1) The SUT supports the O-Cloud Event Notification resources create (Chapter 7.3) and query request, and supports delete an individual subscription resource request. +- 2) The Test Simulator has the functionality to initiate delete a subscription resource. + +#### 5.3.4.3 Initial conditions + +- 1) The simulator (acting as a workload) has started. +- 2) The SUT (O-Cloud) has the Notification service ready and available to receive delete request from the Test Simulator. + +#### 5.3.4.4 Procedure + +Step 1. Send an HTTP2 DELETE request from Test Simulator to SUT with the correct URI format as specified in O-RAN.WG6.O-Cloud Notification API [2] clause 4.1.3. + +Step 2. At the Test Simulator the received HTTP2 response is recorded. + +#### 5.3.4.5 Expected Results + +The test is considered passed if + +- 1) The return code is “204 DELETE”. + +### 5.3.5 Event notification and Notification sanity check + +#### 5.3.5.1 Test Purpose + +The purpose of this test case is to verify the capability of event notification to an event consumer. + +This test case is conditional. If the SUT (O-Cloud) claims to support O-Cloud Notification API, it shall support at least pull mode notification or push mode; for push mode, this case applies. + +#### 5.3.5.2 Test Entrance Criteria + +- 1) The SUT supports the O-Cloud Event Notification subscription and query (Chapter 7.3 and 7.4). +- 2) The Test Simulator has the functionality to receive the event notification. + +#### 5.3.5.3 Initial conditions + +- 1) The simulator (acting as a workload) has started. +- 2) The SUT (O-Cloud) has the Notification service ready and has accepted subscription request from the Test Simulator. +- 3) The resources state change or event can be tracked by SUT(O-Cloud). + +#### 5.3.5.4 Procedure + +Step 1. Send an HTTP2 POST request from SUT to the Test Simulator with the EC's URI format as specified in O-RAN.WG6.O-Cloud Notification API [2] clause 5.1.1 containing the JSON format Event as specified in O-RAN.WG6.O-Cloud Notification API [2] clause 7.2 as the message body. + +Step 2. At the SUT the received HTTP2 response is recorded. + +#### 5.3.5.5 Expected results + +The test is considered passed if + +- 1) The return code is “204 Success”. +- 2) The return code is “400 Bad Request”, without message body, when the request is not correct. +- 3) The return code is “404 Not Found”, without message body, when the URI is not available. + +- 4) The return code is “408 Request Timeout”, without message body, when the subscription resource is already existing. (Not applicable for sanity check) + +### 5.3.6 Event pull status notification + +#### 5.3.6.1 Test Purpose + +The purpose of this test case is to verify the capability of pulling of the event from an event consumer. + +This test case is conditional if the SUT (O-Cloud) claims to support O-Cloud Notification API. it shall support at least pull mode notification or push mode; for pull mode, this case applies. + +#### 5.3.6.2 Test Entrance Criteria + +- 1) The SUT supports the O-Cloud Event Notification subscription and pull request (Chapter 7.3). +- 2) The Test Simulator has the functionality to initiate pull request to the resource status. + +#### 5.3.6.3 Initial conditions + +- 1) The simulator (acting as a workload) has started. +- 2) The SUT (O-Cloud) has the Notification service ready and has accept the subscription request from the Test Simulator. + +#### 5.3.6.4 Procedure + +Step 1. Send an HTTP2 GET request from Test Simulator to SUT with the correct URI format as specified in O-RAN.WG6.O-Cloud Notification API [2] clause 6.1.1. + +Step 2. At the Test Simulator the received HTTP2 response is recorded. + +#### 5.3.6.5 Expected results + +The test is considered passed if + +- 1) The return code is “200 OK”. +- 2) The return code is “404 Not Found”, when event notification resource is not available on this node. + +# 6 AAL API Test + +This is FFS. + +# 7 O2 Interface Test + +## 7.1 General + +The O2 interface test validates that the O-Cloud exposes O2 interfaces which should be fully compliant to latest published O2 Interface Specifications. + +## 7.2 Test Configuration + +### 7.2.1 System Under Test requirements + +The SUT for O2 interface test is an O-Cloud with O2 Services to expose O-RAN O2 interfaces toward SMO. + +### 7.2.2 Test Tools capabilities + +A summary of the tools for functional testing is shown below: + +**Test Tool:** The entity used to simulate SMO to issue O2 API request towards the O-Cloud, e.g., A set of test scripts implemented by [Robot Framework](#) which execute Test Cases specified in the O2 interface test section. + +**Robot:** Robot Framework is a generic test automation framework for acceptance testing and acceptance test-driven development. It is a keyword-driven testing framework that uses tabular test data syntax. + +#### 7.2.2.1 O2 IMS Test Tools capabilities + +Tool simulates SMO to expose API endpoints for O-Clouds to deliver Notifications from O-Cloud to SMO, e.g., An instance of mock server with provisions to accept API calls from O-Cloud upon notification delivery. As below example endpoints include: + +O-Cloud registration API Endpoint: + +`${SMO_ENDPOINT}/mock_smo/v1/O-cloud_observer` + +O-Cloud Inventory Changes Notification API Endpoint: + +`${SMO_ENDPOINT}/mock_smo/v1/o2ims_inventory_observer` + +O-Cloud Alarm Changes Notification API Endpoint: + +`${SMO_ENDPOINT}/mock_smo/v1/o2ims_alarm_observer` + +#### 7.2.2.2 O2 DMS Test Tools capabilities + +For the test for O2 DMS ETSI NFV Profile [4], it is recommended to use Robot Framework as described in [8]. + +## 7.3 O2 IMS Test + +### 7.3.1 O-Cloud succeeds to deliver O-Cloud Available Notification to SMO. + +#### 7.3.1.1 Test Purpose + +The purpose of this test case is to verify O-Cloud can deliver O-Cloud Available Notification to SMO successfully. + +#### 7.3.1.2 Initial conditions + +The Test Tool is running and exposing valid endpoint for O-Cloud to deliver O-Cloud Available notification. + +#### 7.3.1.3 Procedure + +Step 1. Bring up O-Cloud with O2 IMS service by provisioning valid API endpoint of Test Tool, for example: `${SMO_ENDPOINT}/mock_smo/v1/O-cloud_observer` and `globalO-cloudId` assigned for this O-Cloud; + +Step 2. Check if Test Tool received valid O-Cloud Available Notification from O-Cloud via the SMO endpoint. + +#### 7.3.1.4 Expected Results + +The test is considered passed if + +Step1. O-Cloud with O2 Service finished deployment. + +Step2. The Test Tool O-Cloud registration Endpoint receives notification, for example: + +`${SMO_ENDPOINT}/mock_smo/v1/O-cloud_observer` received O-Cloud Available Notification from O2 IMS services with content compliant to [7] section ‘3.6.5.1.1 O-Cloud Available Notification Description’. + +### 7.3.2 SMO succeeds to query inventory with correct token + +#### 7.3.2.1 Test Purpose + +The purpose of this test case is to verify SMO succeeds to query O-Cloud O2ims inventory resources after O-Cloud succeeds in delivering O-Cloud Available notification to SMO. + +#### 7.3.2.2 Initial conditions + +- 1) The Test Tool received O-Cloud Available Notification from O-Cloud. +- 2) Test Tool is provided with `${O2ims-endpoint}` by extracting it from O-Cloud Available Notification. +- 3) Test Tool is provided with valid `${O2ims-api-token}` (by extracting it from O-Cloud Available Notification or some other way). + +#### 7.3.2.3 Procedure + +Step 1. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries O-Cloud detail via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}$ . + +Step 2. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries resource type list without filter via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes}$ . + +Step 3. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries resource type list with filter (e.g., filter by resource type with name: pserver) via API: + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes?filter}=(\text{eq,name,pserver})$ + +Step 4. With valid $\{\text{O2ims-api-token}\}$ , Test Tool to query resource type list with selector (e.g., all\_fields) via API: + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes?all\_fields}$ + +Step 5. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries resource type detail with a valid $\{\text{resource\_type\_id}\}$ via API: + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes}/\{\text{resource\_type\_id}\}$ + +Step 6. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries Resource Pool list without filter via API: + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourcePools}$ + +Step 7. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries Resource Pool list with filter (e.g., filter by a valid $\{\text{resourcePoolId}\}$ ) via API: + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourcePools?filter}=(\text{eq,resourcePoolId},\{\text{resourcePoolId}\})$ + +Step 8. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries Resource Pool list with selector via API: + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourcePools?all\_fields}$ + +Step 9. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries Resource Pool detail via API: + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourcePools}/\{\text{resourcePoolId}\}$ + +Step 10. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries Resource list of a Resource Pool without filter via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourcePools}/\{\text{resourcePoolId}\}/\text{resources}$ + +Step 11. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries Resource list of a Resource Pool with filter via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourcePools}/\{\text{resourcePoolId}\}/\text{resources?filter}=(\text{eq,resourceTypeId},\{\text{resourceTypeId}\})$ + +Step 12. With valid $\{\text{O2ims-api-token}\}$ , Test Tool to query Resource list of a Resource Pool with selector via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourcePools}/\{\text{resourcePoolId}\}/\text{resources?all\_fields}$ + +Step 13. With valid \${O2ims-api-token}, Test Tool queries Resource detail via API: GET \${O2ims-endpoint}/o2ims-infrastructureInventory/v1/resourcePools/\${resourcePoolId}/resources/\${resourceId} + +#### 7.3.2.4 Expected Results + +The test is considered passed if + +- 1) Step 1 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.6 Type: CloudInfo'. +- 2) Step 2 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.2 Type: ResourceTypeInfo'. +- 3) Step 3 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.2 Type: ResourceTypeInfo'. +- 4) Step 4 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.2 Type: ResourceTypeInfo'. +- 5) Step 5 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.2 Type: ResourceTypeInfo'. +- 6) Step 6 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.3 Type: ResourcePoolInfo'. +- 7) Step 7 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.3 Type: ResourcePoolInfo'. +- 8) Step 8 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.3 Type: ResourcePoolInfo'. +- 9) Step 9 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.3 Type: ResourcePoolInfo'. +- 10) Step 10 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.4 ResourceInfo'. +- 11) Step 11 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.4 ResourceInfo'. +- 12) Step 12 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.4 ResourceInfo'. +- 13) Step 13 API response status code should be 200, and response data is compliant to [7] section '3.2.6.2.4 ResourceInfo'. + +### 7.3.3 SMO succeeds to subscribe for O2ims inventory changes notification and succeeds to receive notifications. + +#### 7.3.3.1 Test Purpose + +The purpose of this test case is to verify that after O-Cloud succeeds to deliver O-Cloud Available Notification to SMO, SMO succeeds to subscribe to O-Cloud O2ims inventory changes notification, and SMO succeeds to receive notification when o2ims inventory changes. + +#### 7.3.3.2 Initial conditions + +- 1) The Test Tool received O-Cloud Available Notification from O-Cloud. +- 2) Test Tool is provided with $\{\text{O2ims-endpoint}\}$ by extracting it from O-Cloud Available Notification. +- 3) Test Tool is provided with valid $\{\text{O2ims-api-token}\}$ (by extracting it from O-Cloud Available Notification or some other way). + +#### 7.3.3.3 Procedure + +Step 1. With valid $\{\text{O2ims-api-token}\}$ , Test Tool create a subscription via API: POST $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{subscriptions}$ , the call back field as example: + +$\{\text{SMO\_ENDPOINT}\}/\text{mock\_smo}/\text{v1}/\text{o2ims\_inventory\_observer}$ + +Step 2. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries subscription list without filter via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{subscriptions}$ + +Step 3. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries subscription list with filter (e.g., filter by a valid $\{\text{subscriptionId}\}$ ) via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{subscriptions}?filter=(eq,subscriptionId,\{\text{subscriptionId}\})$ + +Step 4. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries a subscription detail via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{subscriptions}/\{\text{subscriptionId}\}$ + +Step 5. Trigger O2IMS inventory changes from O-Cloud side and observe the Test Tool receiving notification of this O2IMS inventory change. + +Step 6. With valid $\{\text{O2ims-api-token}\}$ , Test Tool delete a subscription via API: DELETE $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{subscriptions}/\{\text{subscriptionId}\}$ + +#### 7.3.3.4 Expected Results + +The test is considered passed if + +- 1) Step 1 API response status code should be 201, and response data is compliant to [7] section ‘3.2.4.11.3.1-2 InventorySubscriptionInfo’. +- 2) Step 2 API response status code should be 200, and response data is compliant to [7] section ‘3.2.4.11.3.2 GET’ +- 3) Step 3 API response status code should be 200, and response data is compliant to [7] section ‘3.2.4.11.3.2 GET’ +- 4) Step 4 API response status code should be 200, and response data is compliant to [7] section ‘3.2.4.12.2 Resource definition’ + +- 5) Step 5 Test Tool O-Cloud Inventory changes Notification API Endpoint, for example: + $\{\text{SMO\_ENDPOINT}\}/\text{mock\_smo}/\text{v1}/\text{o2ims\_inventory\_observer}$ +received the notification upon o2ims inventory change, and response data is compliant to [7] section ‘3.2.5.1.1 Inventory Change Notification Description’ +- 6) Step6. The API response status should be 200, and the response data is compliant with [7] section ‘3.2.4.12.3.5 DELETE’. + +### 7.3.4 SMO succeeds to create alarmSubscription, receive alarm notification, and query alarm list. + +#### 7.3.4.1 Test Purpose + +After O-Cloud succeeds deliver O-Cloud Available notification to SMO, SMO succeeds to subscribe for notification of alarm changes notification, and SMO succeeds to query alarm list and detail, and acknowledge alarm. + +#### 7.3.4.2 Initial conditions + +- 1) The Test Tool received O-Cloud Available Notification from O-Cloud. +- 2) Test Tool is provided with $\{\text{O2ims-endpoint}\}$ by extracting it from O-Cloud Available Notification. +- 3) Test Tool is provided with valid $\{\text{O2ims-api-token}\}$ (by extracting it from O-Cloud Available Notification or some other way). + +#### 7.3.4.3 Procedure + +Step 1. With valid $\{\text{O2ims-api-token}\}$ , Test Tool creates an alarmSubscription for receiving alarm changes notification via API: POST $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureMonitoring}/\text{v1}/\text{alarmSubscriptions}$ , the call back field as example: + +$\{\text{SMO\_ENDPOINT}\}/\text{mock\_smo}/\text{v1}/\text{o2ims\_alarm\_observer}$ + +Step 2. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries alarmSubscription list via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureMonitoring}/\text{v1}/\text{alarmSubscriptions}$ + +Step 3. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries alarmSubscription details with alarmSubscriptionId via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureMonitoring}/\text{v1}/\text{alarmSubscriptions}/\{\text{alarmSubscriptionId}\}$ + +Step 4. Trigger alarm change on O-Cloud side. + +Step 5. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries alarm list via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureMonitoring}/\text{v1}/\text{alarms}$ + +Step 6. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries alarm list with filter via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureMonitoring}/\text{v1}/\text{alarms?filter}=(\text{eq,resourceTypeId},\{\text{resourceTypeId}\})$ + +Step 7. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries alarm list with selector via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureMonitoring}/\text{v1}/\text{alarms?all\_fields}$ + +Step 8. With valid $\{O2ims-api-token\}$ , Test Tool queries alarm detail with alarmEventRecordId via API: GET $\{O2ims-endpoint\}/o2ims-infrastructureMonitoring/v1/alarms/\{alarmEventRecordId\}$ + +Step 9. With valid $\{O2ims-api-token\}$ , Test Tool acknowledge alarm with alarmEventRecordId via API: PATCH $\{O2ims-endpoint\}/o2ims-infrastructureMonitoring/v1/alarms/\{alarmEventRecordId\}$ + +Step 10. With valid $\{O2ims-api-token\}$ , Test Tool deletes alarmSubscription with alarmSubscriptionId via API: DELETE + +$\{O2ims-endpoint\}/o2ims-infrastructureMonitoring/v1/alarms/\{alarmSubscriptionId\}$ + +Step 11. Trigger alarm change on O-Cloud side. + +#### 7.3.4.4 Expected Results + +The test is considered passed if + +- 1) Step 1 API response status code should be 201, and response data is compliant to [7] section ‘3.3.4.4.3.1 POST’. +- 2) Step 2 API response status code should be 200, and response data is compliant to [7] section ‘3.3.4.4.3.2 GET’. +- 3) Step 3 API response status code should be 200, and response data is compliant to [7] section ‘3.3.4.4.3.2 GET’. +- 4) Step 4 Test Tool O-Cloud Alarm Changes Notification API Endpoint, for example: + $\{SMO\_ENDPOINT\}/mock\_smo/v1/o2ims\_alarm\_observer$ +succeeds receiving alarm change notification, and alarm change notification data is compliant to [7] section ‘3.3.5.1.1 Alarm Change Notification Description’. +- 5) Step 5 API response status code should be 200, and response data is compliant to [7] section ‘3.3.4.2.3.2 GET’. +- 6) Step 6 API response status code should be 200, and response data is compliant to [7] section ‘3.3.6.2.2 Type: AlarmEventRecord’. +- 7) Step 7 API response status code should be 200, and response data is compliant to [7] section ‘3.3.6.2.2 Type: AlarmEventRecord’. +- 8) Step 8 API response status code should be 200, and response data is compliant to [7] section ‘3.3.6.2.2 Type: AlarmEventRecord’. +- 9) Step 9 API response status code should be 200, and response data is compliant to [7] section ‘3.3.6.2.4 Type: AlarmEventRecordModifications’. +- 10) Step 10 API response status code should be 200, and response data is compliant to [7] section ‘3.3.4.5.3.5 Delete’. +- 11) Step 11 Observe the Test Tool does not receive alarm change notification anymore. + +### 7.3.5 Verify general aspects of O2ims API. + +#### 7.3.5.1 Test Purpose + +The purpose of this test case is to verify that after O-Cloud succeeds to deliver O-Cloud Available notification to SMO, SMO succeeds to issue API requests complying to '3.1.2 URI structure and supported content formats'. + +#### 7.3.5.2 Initial conditions + +- 1) The Test Tool received O-Cloud Available Notification from O-Cloud. +- 2) Test Tool is provided with $\{\text{O2ims-endpoint}\}$ by extracting it from O-Cloud Available Notification. +- 3) Test Tool is provided with valid $\{\text{O2ims-api-token}\}$ (by extracting it from O-Cloud Available Notification or some other way). + +#### 7.3.5.3 Procedure + +Step 1. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries ApiVersionInformation of o2ims infrastructureInventory services via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{api\_versions}$ + +Step 2. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries ApiVersionInformation of o2ims infrastructureMonitoring service via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureMonitoring}/\text{api\_versions}$ + +Step 3. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries Resources with nextpage\_opaque\_marker via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourcePools}/\{\text{resourcePoolId}\}/\text{resources?nextpage\_opaque\_marker}=2$ + +Step 4. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries resource with filter with below APIs + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourcePools}/\{\text{resourcePoolId}\}/\text{resources?filter}=(\text{eq},\text{resourceId},\{\text{resourceId}\})$ + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourcePools}/\{\text{resourcePoolId}\}/\text{resources?filter}=(\text{neq},\text{resourceId},\{\text{resourceId}\})$ + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes?filter}=(\text{cont},\text{description},\text{Ethernet})$ + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes?filter}=(\text{ncont},\text{description},\text{Ethernet})$ + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes?filter}=(\text{in},\text{name},\text{pserver},\text{pserver\_if},\text{pserver\_mem})$ + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes?filter}=(\text{nin},\text{name},\text{pserver},\text{pserver\_if},\text{pserver\_mem})$ + +Step 5. With valid $\{\text{O2ims-api-token}\}$ , Test Tool queries resources with attribute selector via API: GET + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes?all\_fields}$ + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes?fields=extensions}$ + +$\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{resourceTypes?exclude\_fields=extensions}$ + +`/${O2ims-endpoint}/o2ims-infrastructureInventory/v1/resourceTypes?exclude_default` + +#### 7.3.5.4 Expected Results + +The test is considered passed if + +- 1) Step 1. API response status code should be 200, and response data is compliant to [7] section ‘3.1.6.1.6 Type: ApiVersionInformation’. +- 2) Step 2. API response status code should be 200, and response data is compliant to [7] section ‘3.1.6.1.6 Type: ApiVersionInformation’. +- 3) Step 3. API response status code should be 200, and response data is compliant to [7] section ‘3.1.6.2.2 Simple Data Types’. +- 4) Step 4. API response status code should be 200, and response data is compliant to [7] section ‘3.1.4.3 Handling of large query results’. +- 5) Step 5. API response status code should be 200, and response data is compliant to [7] section ‘3.1.4.3 Handling of large query results’. + +### 7.3.6 SMO gets 405 while sending O2ims APIs with unsupported method. + +#### 7.3.6.1 Test Purpose + +The purpose of this test case is to verify that after O-Cloud succeeds to deliver O-Cloud Available notification to SMO, SMO gets 405 responses while issuing API requests with unsupported method. + +#### 7.3.6.2 Initial conditions + +- 1) The Test Tool received O-Cloud Available Notification from O-Cloud. +- 2) Test Tool is provided with `/${O2ims-endpoint}` by extracting it from O-Cloud Available Notification. +- 3) Test Tool is provided with valid `/${O2ims-api-token}` (by extracting it from O-Cloud Available Notification or some other way). + +#### 7.3.6.3 Procedure + +Step 1. With valid `/${O2ims-api-token}`, Test Tool issues API request with unsupported method to operate `resourceTypes` via API: `POST ${O2ims-endpoint}/o2ims-infrastructureInventory/v1/resourceTypes` + +Step 2. With valid `/${O2ims-api-token}`, Test Tool issues API request with unsupported method to operate `resourcePool` via API: `POST ${O2ims-endpoint}/o2ims-infrastructureInventory/v1/resourcePools` + +Step 3. With valid `/${O2ims-api-token}`, Test Tool issues API request with unsupported method to operate `resource` via API: `POST ${O2ims-endpoint}/o2ims-infrastructureInventory/v1/resourcePools/${resourcePoolId}/resources` + +Step 4. With valid `/${O2ims-api-token}`, Test Tool issues API request with unsupported method to operate `DeploymentManager` via API: `POST ${O2ims-endpoint}/o2ims-infrastructureInventory/v1/deploymentManagers` + +Step 5. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with unsupported method to operate O-cloud via API: POST $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/$ + +Step 6. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with unsupported method to operate Inventory Subscription via API: PATCH $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{subscriptions}$ + +Step 7. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with unsupported method to operate Alarm via API: POST $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{alarms}$ + +Step 8. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with unsupported method to operate Alarm Subscription via API: PATCH $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureMonitoring}/\text{v1}/\text{alarmSubscriptions}$ + +#### 7.3.6.4 Expected Results + +The test is considered passed if + +- 1) Step 1 API response status code should be 405, and response data is compliant to [7] section ‘3.2.4.2.3.1, 3.2.4.2.3.3, 3.2.4.2.3.4, 3.2.4.2.3.5’. +- 2) Step 2 API response status code should be 405, and response data is compliant to [7] section ‘3.2.4.3.3.1, 3.2.4.3.3.3, 3.2.4.3.3.4, 3.2.4.3.3.5’. +- 3) Step 3 API response status code should be 405, and response data is compliant to [7] section ‘3.2.4.4.3.1, 3.2.4.4.3.3, 3.2.4.4.3.4, 3.2.4.4.3.5’. +- 4) Step 4 API response status code should be 405, and response data is compliant to [7] section ‘3.2.4.5.3.1, 3.2.4.5.3.3, 3.2.4.5.3.4, 3.2.4.5.3.5’. +- 5) Step 5 API response status code should be 405, and response data is compliant to [7] section ‘3.2.4.6.3.1, 3.2.4.6.3.3, 3.2.4.6.3.4, 3.2.4.6.3.5’. +- 6) Step 6 API response status code should be 405, and response data is compliant to [7] section ‘3.2.4.7.3.1, 3.2.4.7.3.3, 3.2.4.7.3.4, 3.2.4.7.3.5’. +- 7) Step 7 API response status code should be 405, and response data is compliant to [7] section ‘3.2.4.8.3.1, 3.2.4.8.3.3, 3.2.4.8.3.4, 3.2.4.8.3.5’. +- 8) Step 8 API response status code should be 405, and response data is compliant to [7] section ‘3.2.4.9.3.1, 3.2.4.9.3.3, 3.2.4.9.3.4, 3.2.4.9.3.5’. + +### 7.3.7 SMO gets 400 while issuing O2ims APIs with incorrect data. + +#### 7.3.7.1 Test Purpose + +The purpose of this test case is to verify that after O-Cloud succeeds to deliver O-Cloud Available notification to SMO, SMO gets 400 response with Problem Details while issuing o2ims API requests with incorrect data. + +#### 7.3.7.2 Initial conditions + +- 1) The Test Tool received O-Cloud Available Notification from O-Cloud +- 2) Test Tool is provided with $\{\text{O2ims-endpoint}\}$ by extracting it from O-Cloud Available Notification. + +- 3) Test Tool is provided with valid $\{\text{O2ims-api-token}\}$ (by extracting it from O-Cloud Available Notification or some other way). + +#### 7.3.7.3 Procedure + +Step 1. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with incorrect data to operate resourceTypes via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-}$ + $\text{infrastructureInventory}/\text{v1}/\text{resourceTypes?filter}=(\text{eq}, \text{WrongAttrName}, \text{anyvalue})$ + +Step 2. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with incorrect data to operate resourcePool via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-}$ + $\text{infrastructureInventory}/\text{v1}/\text{resourcePools?filter}=(\text{eq}, \text{WrongAttrName}, \text{anyvalue})$ + +Step 3. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with incorrect data to operate resource via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-}$ + $\text{infrastructureInventory}/\text{v1}/\text{resourcePools}/\{\text{resourcePoolId}\}/\text{resources?filter}=(\text{eq}, \text{WrongAttrName}, \text{anyvalue})$ + +Step 4. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with incorrect data to operate DeploymentManager via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-}$ + $\text{infrastructureInventory}/\text{v1}/\text{deploymentManagers?filter}=(\text{eq}, \text{WrongAttrName}, \text{anyvalue})$ + +Step 5. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with incorrect data to operate O-cloud via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-}$ + $\text{infrastructureInventory}/\text{v1}/\text{?fields}=(\text{O-cloudId}, \text{WrongAttrName})$ + +Step 6. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with incorrect data to operate Inventory Subscription via API: + $\text{GET}/\text{o2ims}/\text{infrastructureInventory}/\text{v1}/\text{subscriptions?fields}=(\text{SubscriptionId}, \text{WrongAttrName})$ + +Step 7. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with incorrect data to operate Alarm via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-}$ + $\text{infrastructureMonitoring}/\text{v1}/\text{alarms?fields}=(\text{AlarmId}, \text{WrongAttrName})$ + +Step 8. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with incorrect data to operate Alarm Subscription via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-}$ + $\text{infrastructureMonitoring}/\text{v1}/\text{alarmSubscriptions?fields}=(\text{AlarmId}, \text{WrongAttrName})$ + +#### 7.3.7.4 Expected Results + +The test is considered passed if + +- 1) Step 1 API response status code should be 400, and response data is compliant to [7] section ‘3.1.5 Error reporting and 3.6.7.2 Protocol errors’. +- 2) Step 2 API response status code should be 400, and response data is compliant to [7] section ‘3.1.5 Error reporting and 3.6.7.2 Protocol errors’. +- 3) Step 3 API response status code should be 400, and response data is compliant to [7] section ‘3.6.7.3 Application errors’. +- 4) Step 4 API response status code should be 400, and response data is compliant to [7] section ‘3.6.7.2 Protocol errors, 3.6.7.3 Application errors’. + +- 5) Step 5 API response status code should be 400, and response data is compliant to [7] section ‘3.6.7.2 Protocol errors ,3.6.7.3 Application errors’. +- 6) Step 6 API response status code should be 400, and response data is compliant to [7] section ‘3.6.7.2 Protocol errors ,3.6.7.3 Application errors’. +- 7) Step 7 API response status code should be 400, and response data is compliant to [7] section ‘3.6.7.2 Protocol errors, 3.6.7.3 Application errors’. +- 8) Step 8 API response status code should be 400, and response data is compliant to [7] section ‘3.6.7.2 Protocol errors ,3.6.7.3 Application errors’. + +### 7.3.8 SMO gets security error response while issuing APIs with incorrect token. + +#### 7.3.8.1 Test Purpose + +The purpose of this test case is to verify that after O-Cloud succeeds to deliver O-Cloud Available notification to SMO, SMO gets error response while issuing API requests with incorrect token data. + +#### 7.3.8.2 Initial conditions + +- 1) The Test Tool received O-Cloud Available Notification from O-Cloud +- 2) Test Tool is provided with $\{\text{O2ims-endpoint}\}$ by extracting it from O-Cloud Available Notification. +- 3) Test Tool is provided with invalid $\{\text{O2ims-api-token}\}$ . + +#### 7.3.8.3 Procedure + +Step 1. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request without Authorization Bearer Token Header via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/$ + +Step 2. With invalid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with Authorization Bearer Token Header and invalid token via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/$ + +Step 3. With invalid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with Authorization Bearer Token Header and valid token via API: GET $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/$ + +#### 7.3.8.4 Expected Results + +The test is considered passed if + +- 1) Step 1 API response status code should be 401, and response data is compliant to [7] section ‘3.1.7.1 Introduction’. +- 2) Step 2 API response status code should be 401, and response data is compliant to [7] section ‘3.1.7.1 Introduction’. +- 3) Step 3 API response status code should be 200, and response data is compliant to [7] section ‘3.1.7.1 Introduction’. + +### 7.3.9 SMO gets client error response while issuing requests with incorrect APIs + +#### 7.3.9.1 Test Purpose + +The purpose of this test case is to verify that after O-Cloud succeeds to deliver O-Cloud Available notification to SMO, SMO gets correct error response while issuing request with incorrect APIs. + +#### 7.3.9.2 Initial conditions + +- 1) The Test Tool has started. + +#### 7.3.9.3 Procedure + +Step 1. With valid \${O2ims-api-token}, Test Tool queries API with wrong port via API: GET \${O2ims-endpoint}/o2ims-infrastructureInventory/v1/deploymentManagers + +Step 2. With valid \${O2ims-api-token}, Test Tool queries API with wrong URL via API: GET \${O2ims-endpoint}/o2ims-infrastructureInventory/v1/deploymentManagersWrongURL + +Step 3. With valid \${O2ims-api-token}, Test Tool queries API with wrong api version via API: GET \${O2ims-endpoint}/o2ims-infrastructureInventory/v2/deploymentManagers + +Step 4. With valid \${O2ims-api-token}, Test Tool queries API with wrong deploymentManagerID via API: GET \${O2ims-endpoint}/o2ims-infrastructureInventory/v1/wrongDeploymentManagerID + +#### 7.3.9.4 Expected Results + +The test is considered passed if + +- 1) Step 1 With valid \${O2ims-api-token}, Test Tool does not receive API response. +- 2) Step 2 API response status code should be 404, and response data is compliant to [7] section ‘3.6.7.1 General, 3.6.7.3 Application errors’. +- 3) Step 3 API response status code should be 404, and response data is compliant to [7] section ‘3.6.7.1 General, 3.6.7.3 Application errors’. +- 4) Step 4 API response status code should be 404, and response data is compliant to [7] section ‘3.6.7.1 General, 3.6.7.3 Application errors’. + +### 7.3.10 SMO succeeds to get O2dms (in Kubernetes native API Profile) access information. + +#### 7.3.10.1 Test Purpose + +The purpose of this test case is to verify SMO succeeds to query deploymentManager to extract O2dms access information after O-Cloud succeeds to deliver O-Cloud Available notification to SMO. + +#### 7.3.10.2 Initial conditions + +- 1) The Test Tool received O-Cloud Available Notification from O-Cloud + +- 2) Test Tool is provided with \${O2ims-endpoint} by extracting it from O-Cloud Available Notification. +- 3) Test Tool is provided with valid \${O2ims-api-token} (by extracting it from O-Cloud Available Notification or some other way). + +#### 7.3.10.3 Procedure + +Step 1. With valid \${O2ims-api-token}, Test Tool queries deploymentManager list without filter via API: GET \${O2ims-endpoint}/o2ims-infrastructureInventory/v1/deploymentManagers + +Step 2. With valid \${O2ims-api-token}, Test Tool queries deploymentManager list with filter (e.g., filter by a valid \${deploymentManagerId}) via API: GET \${O2ims-endpoint}/o2ims-infrastructureInventory/v1/deploymentManagers?filter=(eq, deploymentManagerId, \${deploymentManagerId}) + +Step 3. With valid \${O2ims-api-token}, Test Tool queries a deploymentManager detail via API: GET \${O2ims-endpoint}/o2ims-infrastructureInventory/v1/deploymentManagers/\${deploymentManagerId} + +Step 4. Extract \${k8s\_cluster\_api\_endpoint} from response data of step3, Test Tool queries Kubernetes resources with access credentials from a deploymentManager with Kubernetes API: GET \${k8s\_cluster\_api\_endpoint}/api/v1/namespaces + +#### 7.3.10.4 Expected Results + +The test is considered passed if: + +- 1) Step 1 API response status code should be 200, and response data is compliant to [7] section ‘3.2.4.9.2 Resource Definition, 3.2.4.8.3.2 Get, 3.2.4.8.2 DeploymentManagerInfo’. +- 2) Step 2 API response status code should be 200, and response data is compliant to [7] section ‘3.2.4.8.3.2 Get and 3.2.4.8.2 DeploymentManagerInfo’. +- 3) Step 3 API response status code should be 200, and response data is compliant to [7] section ‘3.2.4.8.3.2 Get and 3.2.6.2.5 DeploymentManagerInfo’. +- 4) Step 4 API response status code should be 200, and response data contains correct Kubernetes resources information. + +### 7.3.11 SMO gets 400 when issuing APIs with junk/unsupported data. + +#### 7.3.11.1 Test Purpose + +The purpose of this test case is to verify that after O-Cloud succeeds to deliver O-Cloud Available notification to SMO, SMO gets 400 response with Problem Details when issuing o2ims API requests with junk/unsupported data. + +#### 7.3.11.2 Initial conditions + +The Test Tool received O-Cloud Available Notification from O-Cloud. + +Test Tool is provided with \${O2ims-endpoint} by extracting it from O-Cloud Available Notification. + +Test Tool is provided with valid $\{O2ims-api-token\}$ (by extracting it from O-Cloud Available Notification or some other way). + +#### 7.3.11.3 Procedure + +Step 1. With valid $\{O2ims-api-token\}$ , Test Tool issues API request with junk data to create inventory subscription via API: POST $\{O2ims-endpoint\}/o2ims-infrastructureInventory/v1/subscriptions$ + +Step 2. With valid $\{O2ims-api-token\}$ , Test Tool issues API request with unsupported data, such as xml, to create inventory subscription via API: POST $\{O2ims-endpoint\}/o2ims-infrastructureInventory/v1/subscriptions$ + +Step 3. With valid $\{O2ims-api-token\}$ , Test Tool issues API request with junk data to create alarm subscription via API: POST $\{O2ims-endpoint\}/o2ims-infrastructureMonitoring/v1/alarmSubscriptions$ + +Step 4. With valid $\{O2ims-api-token\}$ , Test Tool issues API request with unsupported data, such as xml to create alarm subscription via API: POST $\{O2ims-endpoint\}/o2ims-infrastructureInventory/v1/alarmSubscriptions$ + +#### 7.3.11.4 Expected Results + +The test is considered passed if: + +- 1) Step 1 API response status code should be 400, and response data is compliant to [7] section ‘3.1.5 Error reporting and 3.6.7.2 Protocol errors’. +- 2) Step 2 API response status code should be 400, and response data is compliant to [7] section ‘3.6.7.2 Protocol errors, 3.6.7.3 Application errors’. +- 3) Step 3 API response status code should be 400, and response data is compliant to [7] section ‘3.1.5 Error reporting and 3.6.7.2 Protocol errors’. +- 4) Step 4 API response status code should be 400, and response data is compliant to [7] section ‘3.6.7.2 Protocol errors, 3.6.7.3 Application errors’. + +### 7.3.12 SMO gets 404 when issuing APIs with wrong data. + +#### 7.3.12.1 Test Purpose + +The purpose of this test case is to verify that after O-Cloud succeeds to deliver O-Cloud Available notification to SMO, SMO gets 404 response with Problem Details when issuing o2ims API requests with wrong data. + +#### 7.3.12.2 Initial conditions + +- 1) The Test Tool received O-Cloud Available Notification from O-Cloud. +- 2) Test Tool is provided with $\{O2ims-endpoint\}$ by extracting it from O-cloud Available Notification. +- 3) Test Tool is provided with valid $\{O2ims-api-token\}$ (by extracting it from O-Cloud Available Notification or some other way). + +#### 7.3.12.3 Procedure + +Step 1. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with wrong subscriptionId to delete inventory subscription via API: DELETE $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureInventory}/\text{v1}/\text{subscriptions}/\{\text{subscriptionId}\}$ + +Step 2. With valid $\{\text{O2ims-api-token}\}$ , Test Tool issues API request with wrong alarmSubscriptionId, to delete alarm subscription via API: DELETE $\{\text{O2ims-endpoint}\}/\text{o2ims-infrastructureMonitoring}/\text{v1}/\text{alarmSubscriptions}/\{\text{alarmSubscriptionId}\}$ + +#### 7.3.12.4 Expected Results + +The test is considered passed if: + +- 1) Step 1 API response status code should be 404, and response data is compliant to [7] section ‘3.1.5 Error reporting and 3.6.7.2 Protocol errors’. +- 2) Step 2 API response status code should be 404, and response data is compliant to [7] section ‘3.1.5 Error reporting and 3.6.7.2 Protocol errors’. + +## 7.4 O2 DMS Test + +### 7.4.1 General + +Regarding the O-RAN O2dms interface, the present document version specifies the testing of the following profile specification(s): + +- ETSI NFV Protocol specified by O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4]. + +### 7.4.2 O2 DMS ETSI NFV Profile Test + +#### 7.4.2.1 Overview + +For the API conformance testing of APIs specified in O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], the following items shall apply for each test case define in each sub-clause + +- The generic test description shall follow the provisions defined in clause 4.5 of ETSI GS NFV-TST 010 [6]. +- The test suite for the O2DMS ETSI NFV profile API produced by the O-Cloud DMS as specified in the O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4] shall follow the provisions in Annex E and Annex F of ETSI GS NFV-TST 010 [6]. + +NOTE: O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4] is a profiling spec of ETSI GS NFV-SOL 003 [5]. ETSI GS NFV-TST 010 [6] is a test spec for ETSI NFV specifications which includes ETSI GS NFV-SOL 003 [5] as test target. + +#### 7.4.2.2 Test configuration + +For the O2 DMS ETSI NFV Profile test, the test configuration of O-Cloud DMS as producer of VNFM-defined APIs, shall follow the provisions specified in clause 4.3.1 and c4.3.3 of ETSI GS NFV-TST 010 [6], and AUT is O-Cloud DMS. + +#### 7.4.2.3 Test case for Service operations + +##### 7.4.2.3.1 Lifecycle Service operations + +###### 7.4.2.3.1.1 Instantiate NF Deployment test case + +In order to test Instantiate NF Deployment specified in clause 2.4.2.1 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.1.22.1 “Create VNF Instance workflow” +- Test ID 7.3.1.26.1 “VNF Instantiation workflow” +- Test ID 7.3.1.12.2 “Get Individual VNF LCM Operation occurrences” + +###### 7.4.2.3.1.2 Terminate NF Deployment test case + +In order to test Terminate NF Deployment specified in clause 2.4.2.2 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following tests specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.1.33.1 “Terminate a VNF Instance” +- Test ID 7.3.1.23.1 “Delete VNF Instance workflow” +- Test ID 7.3.1.12.2 “Get Individual VNF LCM Operation occurrences” + +###### 7.4.2.3.1.3 Query NF Deployment test case + +In order to test Query NF Deployment specified in clause 2.4.2.3 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following tests specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.1.1.2 “GET information about multiple VNF instances” +- Test ID 7.3.1.2.2 “Get Information about an individual VNF Instance” + +###### 7.4.2.3.1.4 Heal NF Deployment test case + +In order to test Heal NF Deployment specified in clause 2.4.2.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following tests specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.1.8.1 “POST Heal a VNF Instance” +- Test ID 7.3.1.12.2 “Get Individual VNF CM Operation occurrences” + +###### 7.4.2.3.1.5 Scale NF Deployment test case + +In order to test Scale NF Deployment specified in clause 2.4.2.5 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following tests specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.1.4.1 “POST Scale a VNF Instance” + +- Test ID 7.3.1.5.1 “POST Scale a VNF Instance to level” +- Test ID 7.3.1.12.2 “Get Individual VNF LCM Operation occurrences” + +###### 7.4.2.3.1.6 Change external connectivity of an NF Deployment test case + +In order to test Change external connectivity of an NF Deployment specified in clause 2.4.2.6 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following tests specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.1.10.1 “POST Change external VNF connectivity” +- Test ID 7.3.1.12.2 “Get Individual VNF LCM Operation occurrences” + +###### 7.4.2.3.1.7 Change current NF Deployment package test case + +In order to test Change current NF Deployment package specified in clause 2.4.2.7 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following tests specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.1.12.2 “Get Individual VNF LCM Operation occurrences” +- Test ID 7.3.1.37.1 “ChangeCurrentVNFPackageTask” + +###### 7.4.2.3.1.8 Change NF Deployment flavour test case + +In order to test Change NF Deployment flavour specified in clause 2.4.2.8 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following tests specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.1.6.1 “POST Change deployment flavour of a vnfInstance” +- Test ID 7.3.1.12.2 “Get Individual VNF LCM Operation occurrences” + +##### 7.4.2.3.2 Fault Service operations + +###### 7.4.2.3.2.1 Get alarm list test case + +In order to test Get alarm list specified in clause 2.4.3.1 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.5.1.2 “Get information about multiple alarms” +- Test ID 7.3.5.2.2 “Get information about an fault management individual alarm” + +###### 7.4.2.3.2.2 Notify test case + +In order to test Notify specified in clause 2.4.3.2 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.5.5.1 “VNF Fault Alarm Notification” + +###### 7.4.2.3.2.3 Acknowledge alarm test case + +In order to test Acknowledge alarm specified in clause 2.4.3.3 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.5.2.4 “PATCH Fault Management Individual Alarm” + +##### 7.4.2.3.3 Performance Service operations + +###### 7.4.2.3.3.1 Create PM Job test case + +In order to test Create PM Job specified in clause 2.4.4.1 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.4.1.9 “Create new VNF Performance Monitoring Job” + +###### 7.4.2.3.3.2 Query/read PM job information test case + +In order to test Query/read PM job information specified in clause 2.4.4.2 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.4.1.1 “GET all VNF Performance Monitoring Jobs” +- Test ID 7.3.4.2.1 “GET individual VNF Performance Job” + +###### 7.4.2.3.3.3 Delete a PM job test case + +In order to test Delete a PM job specified in clause 2.4.4.3 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.4.2.3 “DELETE Individual VNF Performance Job” + +###### 7.4.2.3.3.4 Create a threshold test case + +In order to test Create a threshold specified in clause 2.4.4.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.4.4.5 “Create new Performance Threshold” + +###### 7.4.2.3.3.5 Query/read threshold information test case + +In order to test Query/read threshold information specified in clause 2.4.4.5 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.4.4.1 “GET All Performance Thresholds” + +- Test ID 7.3.4.5.1 “GET Individual Threshold” + +###### 7.4.2.3.3.6 Delete a threshold test case + +In order to test Delete a threshold specified in clause 2.4.4.6 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.4.5.3 “DELETE Individual Threshold” + +##### 7.4.2.3.3.7 Sending performance related notifications test case + +In order to test Sending performance related notifications specified in clause 2.4.4.7 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.4.8.1 “VNF Performance Information Availability Notification” +- Test ID 7.3.4.8.2 “VNF Threshold Crossed Notification” + +###### 7.4.2.3.3.8 Obtaining performance reports test case + +In order to test Obtaining performance reports specified in clause 2.4.4.8 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed: + +- Test ID 7.3.4.8.1 “VNF Performance Information Availability Notification” +- Test ID 7.3.4.1.1 “GET all VNF Performance Monitoring Jobs” +- Test ID 7.3.4.3.1 “Get Individual Performance Report” + +#### 7.4.2.4 Test case for O2dms\_DeploymentLifecycle Service API + +##### 7.4.2.4.1 VNF instances REST resource test case + +In order to test VNF instances REST resource specified in clause 3.2.4.2 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.1.1 “POST Create a new vnfInstance” +- Test ID 7.3.1.1.2 “GET information about multiple VNF instances” +- Test ID 7.3.1.1.3 “GET information about multiple VNF instances Bad Request Invalid attribute-based filtering parameters” +- Test ID 7.3.1.1.4 “GET information about multiple VNF instances Bad Request Invalid attribute selector” +- Test ID 7.3.1.1.5 “GET information about multiple VNF instances with "all\_fields" attribute selector” +- Test ID 7.3.1.1.6 “GET information about multiple VNF instances with "exclude\_default" attribute selector” +- Test ID 7.3.1.1.7 “GET information about multiple VNF instances with "fields" attribute selector” + +- Test ID 7.3.1.1.8 “GET information about multiple VNF instances with "exclude\_fields" attribute selector” +- Test ID 7.3.1.1.12 “GET information about multiple VNF instances to get Paged Response” +- Test ID 7.3.1.1.12a “GET information about multiple VNF instances as a Paged Response with nextpage\_opaque\_marker parameter” +- Test ID 7.3.1.1.13 “GET information about multiple VNF instances - Bad Request Response too Big” +- Test ID 7.3.1.1.14 “GET information about multiple VNF instances with "exclude\_default" and "fields" attribute selector” +- Test ID 7.3.1.1.15 “POST Create a new vnfInstance - Unprocessable Entity” +- Test ID 7.3.1.1.16 “GET information about multiple VNF instances using Filter” + +##### 7.4.2.4.2 Individual VNF instance REST resource test case + +In order to test Individual VNF instance REST resource specified in clause 3.2.4.3 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.2.2 “Get Information about an individual VNF Instance” +- Test ID 7.3.1.2.4 “PATCH Individual VNFInstance” +- Test ID 7.3.1.2.5 “PATCH Individual VNFInstance Precondition failed” +- Test ID 7.3.1.2.6 “PATCH Individual VNFInstance Conflict” +- Test ID 7.3.1.2.7 “DELETE Individual VNFInstance” +- Test ID 7.3.1.2.8 “The objective is to verify that the deletion cannot be executed currently, due to a conflict with the state of the VNF instance resource.” +- Test ID 7.3.1.2.9 “Get Information about an individual VNF Instance - Not Found” + +##### 7.4.2.4.3 Instantiate VNF task REST resource test case + +In order to test Instantiate VNF task REST resource specified in clause 3.2.4.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.3.1 “Post Instantiate Individual VNFInstance” +- Test ID 7.3.1.3.2 “Post Instantiate Individual VNFInstance” + +##### 7.4.2.4.4 Terminate VNF task REST resource test case + +In order to test Terminate VNF task REST resource specified in clause 3.2.4.5 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.7.1 “POST Terminate a vnfInstance” +- Test ID 7.3.1.7.2 “POST Terminate a vnfInstance Conflict (Not-Instantiated)” + +##### 7.4.2.4.5 Notification test case + +In order to test Notifications issued on the O2dms\_DeploymentLifecycle Service API specified in clause 3.2.5 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.34.1 “VNF LCM Operation Occurrence Start Notification” +- Test ID 7.3.1.34.2 “VNF LCM Operation Occurrence Result Notification” +- Test ID 7.3.1.34.3 “VNF Identifier Creation Notification” +- Test ID 7.3.1.34.4 “VNF Identifier Deletion Notification” + +##### 7.4.2.4.6 Heal VNF task REST resource test case + +In order to test Heal VNF task REST resource specified in clause 3.2.4.6 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.8.1 “POST Heal a vnfInstance” +- Test ID 7.3.1.8.2 “POST Heal a vnfInstance Conflict (Not-Instantiated)” +- Test ID 7.3.1.8.3 “POST Heal a vnfInstance Not Found” + +##### 7.4.2.4.7 Scale VNF task REST resource test case + +In order to test Scale VNF task REST resource specified in clause 3.2.4.11 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.4.1 “POST Scale a vnfInstance” +- Test ID 7.3.1.4.2 “POST Scale a vnfInstance Conflict (Not-Instantiated)” +- Test ID 7.3.1.4.3 “POST Scale a vnfInstance Not Found” + +##### 7.4.2.4.8 Scale VNF to Level task REST resource test case + +In order to test Scale VNF to Level task REST resource specified in clause 3.2.4.12 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.5.1 “POST Scale a vnfInstance to level” +- Test ID 7.3.1.5.2 “POST Scale a vnfInstance to level Conflict (Not-Instantiated)” +- Test ID 7.3.1.5.8 “POST Scale a vnfInstance to level with scaleInfo attribute” + +##### 7.4.2.4.9 Change external VNF connectivity task REST resource test case + +In order to test Change external VNF connectivity task REST resource specified in clause 3.2.4.13 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.10.1 “POST Change external VNF connectivity” + +##### 7.4.2.4.10 Retry operation task REST resource test case + +In order to test Retry operation task REST resource specified in clause 3.2.4.7 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.13.1 “Post Retry operation task” +- Test ID 7.3.1.13.2 “Post Retry operation task Conflict (Not-FAILED\_TEMP)” +- Test ID 7.3.1.13.3 “Post Retry operation task Not Found” + +##### 7.4.2.4.11 Rollback operation task REST resource test case + +In order to test Rollback operation task REST resource specified in clause 3.2.4.8 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.14.1 “Post Rollback operation task” +- Test ID 7.3.1.14.2 “POST Rollback operation task Conflict (Not-FAILED\_TEMP)” +- Test ID 7.3.1.14.3 “POST Rollback operation task Not Found” + +##### 7.4.2.4.12 Fail operation task REST resource test case + +In order to test Fail operation task REST resource specified in clause 3.2.4.9 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.15.1 “POST Fail operation task” +- Test ID 7.3.1.15.2 “Post Fail operation task Conflict (Not-FAILED\_TEMP)” +- Test ID 7.3.1.15.3 “Post Fail operation task Not Found” + +##### 7.4.2.4.13 Cancel operation task REST resource test case + +In order to test Cancel operation task REST resource specified in clause 3.2.4.10 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.1.16.1 “POST Cancel operation task” +- Test ID 7.3.1.16.2 “POST Cancel operation task Conflict” +- Test ID 7.3.1.16.3 “POST Cancel operation task Not Found” + +#### 7.4.2.5 Test case for O2dms\_Fault Service API + +##### 7.4.2.5.1 Alarms REST resource test case + +In order to test Alarms REST resource specified in clause 3.3.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.5.1.2 “Get information about multiple alarms” +- Test ID 7.3.5.1.3 “Get information about multiple alarms with filter” +- Test ID 7.3.5.1.4 “Get information about multiple alarms Bad Request Invalid attribute-based filtering parameters” +- Test ID 7.3.5.1.12 “Get information about multiple alarms as a Paged Response” +- Test ID 7.3.5.1.12a “GET information about multiple alarms as a Paged Response with nextpage\_opaque\_marker parameter” +- Test ID 7.3.5.1.13 “Get information about multiple alarms - Bad Request Response too Big” + +##### 7.4.2.5.2 Individual alarm REST resource test case + +In order to test Individual alarm REST resource specified in clause 3.3.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.5.2.2 “Get information about an fault management individual alarm” +- Test ID 7.3.5.2.4 “PATCH Fault Management Individual Alarm” +- Test ID 7.3.5.2.5 “Modify an individual alarm resource - Precondition failed” +- Test ID 7.3.5.2.6 “Modify an individual alarm resource - Conflict” +- Test ID 7.3.5.2.8 “Get information about an fault management individual alarm - Not Found” + +##### 7.4.2.5.3 Subscriptions REST resource test case + +In order to test Subscriptions REST resource specified in clause 3.3.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.5.3.1 “Create a new Fault Management alarm subscription” +- Test ID 7.3.5.3.2 “Create a new alarm subscription - DUPLICATION” +- Test ID 7.3.5.3.3 “Create a new alarm subscription - NO DUPLICATION” +- Test ID 7.3.5.3.4 “Retrieve a list of alarm subscriptions” +- Test ID 7.3.5.3.5 “Retrieve a list of alarm subscriptions with filter” +- Test ID 7.3.5.3.6 “GET subscriptions - Bad Request Invalid attribute-based filtering parameters” +- Test ID 7.3.5.3.7 “GET subscriptions with "all\_fields" attribute selector” +- Test ID 7.3.5.3.8 “GET subscriptions with "exclude\_default" attribute selector” + +- Test ID 7.3.5.3.9 “GET subscriptions with "fields" attribute selector” +- Test ID 7.3.5.3.10 “GET subscriptions with "exclude\_fields" attribute selector” +- Test ID 7.3.5.3.14 “Retrieve a list of alarm subscriptions as Paged Response” +- Test ID 7.3.5.3.15 “GET subscriptions - Bad Request Response too Big” +- Test ID 7.3.5.3.16 “GET Subscription with attribute-based filter "id"” +- Test ID 7.3.5.3.17 “GET Subscription with attribute-based filter "filter.notificationTypes"” +- Test ID 7.3.5.3.18 “GET Subscription with attribute-based filter "filter.faultyResourceTypes"” +- Test ID 7.3.5.3.19 “GET Subscription with attribute-based filter "filter.perceivedSeverities"” +- Test ID 7.3.5.3.20 “GET Subscription with attribute-based filter "filter.eventTypes"” +- Test ID 7.3.5.3.21 “GET Subscription with attribute-based filter "filter.probableCauses"” +- Test ID 7.3.5.3.22 “POST Create a new Subscription - Unprocessable Entity” + +##### 7.4.2.5.4 Individual subscription REST resource test case + +In order to test Individual subscription REST resource specified in clause 3.3.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.5.4.2 “Get Information about an individual subscription” +- Test ID 7.3.5.4.5 “DELETE an individual subscription” +- Test ID 7.3.5.4.6 “Get Information about an individual subscription - Not Found” + +##### 7.4.2.5.5 Notification endpoint REST resource test case + +In order to test Notification endpoint REST resource specified in clause 3.3.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.5.5.1 “VNF Fault Alarm Notification” +- Test ID 7.3.5.5.2 “VNF Fault Alarm Cleared Notification” +- Test ID 7.3.5.5.3 “VNF Fault Alarm List Rebuilt Notification” + +#### 7.4.2.6 Performance Service API + +##### 7.4.2.6.1 PM jobs REST resource test case + +In order to test PM jobs REST resource specified in clause 3.4.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.4.1.1 “GET all VNF Performance Monitoring Jobs” +- Test ID 7.3.4.1.2 “GET all VNF Performance Monitoring Jobs with attribute-based filter” + +- Test ID 7.3.4.1.3 “GET all VNF Performance Monitoring Jobs with all\_fields attribute selector” +- Test ID 7.3.4.1.4 “GET all VNF Performance Monitoring Jobs with exclude\_default attribute selector” +- Test ID 7.3.4.1.5 “GET all VNF Performance Monitoring Jobs with fields attribute selector” +- Test ID 7.3.4.1.6 “GET all VNF Performance Monitoring Jobs with exclude\_fields attribute selector” +- Test ID 7.3.4.1.7 “GET VNF Performance Monitoring Jobs with invalid attribute-based filter” +- Test ID 7.3.4.1.8 “GET VNF Performance Monitoring Jobs with invalid resource endpoint” +- Test ID 7.3.4.1.9 “Create a new VNF Performance Monitoring Job” +- Test ID 7.3.4.1.13 “GET all VNF Performance Monitoring Jobs as Paged Response” +- Test ID 7.3.4.1.13a “GET all VNF Performance Monitoring Jobs as Paged Response with nextpage\_opaque\_marker parameter” +- Test ID 7.3.4.1.14 “GET VNF Performance Monitoring Jobs - Bad Request Response too Big” +- Test ID 7.3.4.1.15 “GET all VNF Performance Monitoring Jobs with fields and exclude\_default attribute selector” +- Test ID 7.3.4.1.16 “POST Create new VNF Performance Monitoring Job - Unprocessable Entity” + +##### 7.4.2.6.2 Individual PM job REST resource test case + +In order to test Individual PM job REST resource specified in clause 3.4.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.4.2.1 “Get individual VNF Performance Job” +- Test ID 7.3.4.2.2 “Get individual VNF Performance Job with invalid resource identifier” +- Test ID 7.3.4.2.3 “Delete Individual VNF Performance Job” +- Test ID 7.3.4.2.4 “Delete individual VNF Performance Job with invalid resource identifier” +- Test ID 7.3.4.2.7 “PATCH Individual VNF Performance Job” +- Test ID 7.3.4.2.8 “PATCH Individual VNF Performance Job - Precondition failed” +- Test ID 7.3.4.2.9 “PATCH Individual VNF Performance Job - Unprocessable Entity” + +##### 7.4.2.6.3 Individual performance report REST resource test case + +In order to test Individual performance report REST resource specified in clause 3.4.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.4.3.1 “Get Individual Performance Report” +- Test ID 7.3.4.3.2 “Get Individual Performance Report with invalid resource endpoint” + +##### 7.4.2.6.4 Thresholds REST resource test case + +In order to test Thresholds REST resource specified in clause 3.4.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.4.4.1 “GET All Performance Thresholds” +- Test ID 7.3.4.4.2 “GET Performance Thresholds with attribute-based filter” +- Test ID 7.3.4.4.3 “GET Performance Thresholds with invalid attribute-based filter” +- Test ID 7.3.4.4.4 “GET Performance Thresholds with invalid resource endpoint” +- Test ID 7.3.4.4.5 “Create new Performance Threshold” +- Test ID 7.3.4.4.9 “GET All Performance Thresholds as Paged Response” +- Test ID 7.3.4.4.10 “GET Performance Thresholds - Bad Request Response too Big” +- Test ID 7.3.4.4.11 “POST create new Performance Threshold - Unprocessable Entity” + +##### 7.4.2.6.5 Individual threshold REST resource test case + +In order to test Individual threshold REST resource specified in clause 3.4.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.4.5.1 “GET Individual Threshold” +- Test ID 7.3.4.5.2 “GET Individual Threshold with invalid resource identifier” +- Test ID 7.3.4.5.3 “DELETE Individual Threshold” +- Test ID 7.3.4.5.4 “DELETE Individual Threshold with invalid resource identifier” +- Test ID 7.3.4.5.7 “PATCH Individual Threshold” +- Test ID 7.3.4.5.8 “PATCH Individual Threshold - Precondition failed” +- Test ID 7.3.4.5.9 “PATCH Individual Threshold - Unprocessable Entity” + +##### 7.4.2.6.6 Notification endpoint REST resource test case + +In order to test Notification endpoint specified in clause 3.4.4 of O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE [4], following test specified in Annex F.7 of ETSI GS NFV-TST 010 [6] shall be followed. + +- Test ID 7.3.4.8.1 “VNF Performance Information Availability Notification” +- Test ID 7.3.4.8.2 “VNF Threshold Crossed Notification” + +# Annex A (normative): Checklist for Cases applies to O-Cloud technologies + +This section provides a list of test cases applicable to each O-Cloud technology. + +## A.1 O-Cloud technologies + +This specification covers following O-Cloud technologies: + +- VMs only +- Containers only +- Containers in VMs + +## A.2 Cloud Technology Applicability of test cases + +Cases marked with Y apply to the corresponding cloud technologies should be executed. + +**Table A.2-1: O-Cloud IOT and corresponding Interfaces/APIs, DUTs and SUTs** + +| Test | Case Title | VMs only | Containers only | Containers in VMs | +|-------------------------------|--------------------------------------------------|----------|-----------------|-------------------| +| O-Cloud Notification API Test | Create a subscription resource | Y | Y | Y | +| | Get a list of subscription resources | Y | Y | Y | +| | Get Detail of individual subscription resource | Y | Y | Y | +| | Delete individual subscription resources | Y | Y | Y | +| | Event notification and Notification sanity check | Y | Y | Y | +| | Event pull status notification | Y | Y | Y | +| O2 Interface | O-Cloud succeeds to deliver O-Cloud | | Y | Y | + +| | | | | | +|----------------------|-----------------------------------------------------------------------------------------------------------|--|---|---| +| Test: O2<br>IMS Test | Available notification to SMO via valid endpoint. | | | | +| | SMO succeeds to query inventory with O2ims APIs and correct token | | Y | Y | +| | SMO succeeds to subscribe for O2ims inventory changes notification and succeeds to receive notifications. | | Y | Y | +| | SMO succeeds to get O2dms (in Kubernetes native API Profile) access information. | | Y | Y | +| | SMO succeeds to create alarmSubscription, receive alarm notification, and query alarm list. | | Y | Y | +| | Verify general aspects of O2ims API. | | Y | Y | +| | SMO gets 405 when sending O2ims APIs with unsupported method. | | Y | Y | +| | SMO gets 400/405 when issuing O2ims APIs with incorrect data. | | Y | Y | +| | SMO gets security error response | | Y | Y | + +| | | | | | +|----------------------------------------------------------------|---------------------------------------------------------------------------|---|---|---| +| | when issuing APIs with incorrect token. | | | | +| | SMO gets client error response when issuing requests with incorrect APIs. | | Y | Y | +| | SMO gets 406/415 when issuing APIs with junk/unsupported data. | | Y | Y | +| | SMO gets 404 when issuing APIs with wrong data. | | Y | Y | +| O2<br>Interface<br>Test: O2<br>DMS ETSI<br>NFV<br>Profile Test | Instantiate NF Deployment test case | Y | N | Y | +| | Terminate NF Deployment test case | Y | N | Y | +| | Query NF Deployment test case | Y | N | Y | +| | Heal NF Deployment test case | Y | N | Y | +| | Scale NF Deployment test case | Y | N | Y | +| | Change external connectivity of an NF Deployment test case | Y | N | Y | +| | Change current NF Deployment package | Y | N | Y | + +| | | | | | +|--|-----------------------------------------------------|---|---|---| +| | Change NF Deployment flavour | Y | N | Y | +| | Get alarm list test case | Y | N | Y | +| | Notify test case | Y | N | Y | +| | Acknowledge alarm test case | Y | N | Y | +| | Create PM Job test case | Y | N | Y | +| | Query/read PM job information test case | Y | N | Y | +| | Delete a PM job test case | Y | N | Y | +| | Create a threshold test case | Y | N | Y | +| | Query/read threshold information test case | Y | N | Y | +| | Delete a threshold test case | Y | N | Y | +| | Sending performance related notifications test case | Y | N | Y | +| | Obtaining performance reports test case | Y | N | Y | +| | VNF instances REST resource test case | Y | N | Y | +| | Individual VNF instance REST resource test case | Y | N | Y | + +| | | | | +|---------------------------------------------------------------|---|---|---| +| Instantiate VNF task REST resource test case | Y | N | Y | +| Terminate VNF task REST resource test case | Y | N | Y | +| Notification test case | Y | N | Y | +| Heal VNF task REST resource test case | Y | N | Y | +| Scale VNF task REST resource test case | Y | N | Y | +| Scale VNF to Level task REST resource test case | Y | N | Y | +| Change external VNF connectivity task REST resource test case | Y | N | Y | +| Retry operation task REST resource test case | Y | N | Y | +| Rollback operation task REST resource test case | Y | N | Y | +| Fail operation task REST resource test case | Y | N | Y | +| Cancel operation task REST resource test case | Y | N | Y | +| Alarms REST resource test case | Y | N | Y | + +| | | | | +|-------------------------------------------------------|---|---|---| +| Individual alarm REST resource test case | Y | N | Y | +| Subscriptions REST resource test case | Y | N | Y | +| Individual subscription REST resource test case | Y | N | Y | +| Notification endpoint REST resource test case | Y | N | Y | +| PM jobs REST resource test case | Y | N | Y | +| Individual PM job REST resource test case | Y | N | Y | +| Individual performance report REST resource test case | Y | N | Y | +| Thresholds REST resource test case | Y | N | Y | +| Individual threshold REST resource test case | Y | N | Y | +| Notification endpoint REST resource test case | Y | N | Y | + +## A.3 Case Traceability + +**Table A.3-1: O-Cloud IOT and corresponding Interfaces/APIs, DUTs and SUTs** + +| Test | Test case | Reference | Requirement | +|-------------------------------|--------------------------------|-----------------------------------------------|-------------| +| O-Cloud Notification API Test | Create a subscription resource | [2] O-RAN.WG6.O-Cloud Notification API-v03.00 | 4.1.2.1 | + +| | | | | +|--------------------------------|-----------------------------------------------------------------------------------------------------------|-----------------------------------------------|-----------------------------------------------------------------------------------------------------------------------| +| | Get a list of subscription resources | [2] O-RAN.WG6.O-Cloud Notification API-v03.00 | 4.1.2.2 | +| | Get Detail of individual subscription resource | [2] O-RAN.WG6.O-Cloud Notification API-v03.00 | 4.1.3.2 | +| | Delete individual subscription resources | [2] O-RAN.WG6.O-Cloud Notification API-v03.00 | 4.1.3.1 | +| | Event notification and Notification sanity check | [2] O-RAN.WG6.O-Cloud Notification API-v03.00 | 5.1.1 | +| | Event pull status notification | [2] O-RAN.WG6.O-Cloud Notification API-v03.00 | 6.1.1 | +| O2 Interface Test: O2 IMS Test | O-Cloud succeeds to deliver O-Cloud Available notification to SMO via valid endpoint. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-GEN6; REQ-ORC-GEN7; REQ-ORC-GEN8; REQ-ORC-GEN9; REQ-ORC-O2-3; REQ-ORC-O2-4;<br><br>REQ-ORC-O2-5; REQ-ORC-O2-6 | +| | SMO succeeds to query inventory with O2ims APIs and correct token. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-GEN10; REQ-ORC-GEN11; REQ-ORC-GEN12; REQ-ORC-GEN13; REQ-ORC-O2-7; REQ-ORC-O2-8 | +| | SMO succeeds to subscribe for O2ims inventory changes notification and succeeds to receive notifications. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-GEN10; REQ-ORC-GEN11; REQ-ORC-GEN12; REQ-ORC-GEN13; REQ-ORC-O2-7; REQ-ORC-O2-8 | +| | SMO succeeds to get O2dms (in | [1] O-RAN.WG6.ORCH- | REQ-ORC-GEN6; REQ-ORC-GEN7; REQ-ORC-GEN8; REQ- | + +| | | | | +|--|---------------------------------------------------------------------------------------------|------------------------------------------|------------------------------------------------------------------------------------------| +| | Kubernetes native API Profile) access information. | USE-CASES-R003-v06.00 | ORC-GEN9; REQ-ORC-O2-3; REQ-ORC-O2-4; REQ-ORC-O2-5; REQ-ORC-O2-6 | +| | SMO succeeds to create alarmSubscription, receive alarm notification, and query alarm list. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-O2-21, REQ-ORC-O2-22, REQ-ORC-O2-16, REQ-ORC-O2-23, REQ-ORC-O2-24, REQ-ORC-O2-15 | +| | Verify general aspects of O2ims API. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-O2-19, REQ-ORC-O2-20 | +| | SMO gets 405 when sending O2ims APIs with unsupported method. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-O2-50, REQ-ORC-O2-51 | +| | SMO gets 400/405 when issuing O2ims APIs with incorrect data. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-O2-19, REQ-ORC-O2-20 | +| | SMO gets security error response when issuing APIs with incorrect token. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-O2-19, REQ-ORC-O2-20 | +| | SMO gets client error response when issuing requests with incorrect APIs. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-O2-19, REQ-ORC-O2-20 | + +| | | | | +|-------------------------------------------------|----------------------------------------------------------------|------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------| +| | SMO gets 406/415 when issuing APIs with junk/unsupported data. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-GEN6; REQ-ORC-GEN7; REQ-ORC-GEN8; REQ-ORC-GEN9; REQ-ORC-O2-3; REQ-ORC-O2-4;<br><br>REQ-ORC-O2-5; REQ-ORC-O2-6 | +| | SMO gets 404 when issuing APIs with wrong data. | [1] O-RAN.WG6.ORCH-USE-CASES-R003-v06.00 | REQ-ORC-O2-21, REQ-ORC-O2-22, REQ-ORC-O2-16,<br><br>REQ-ORC-O2-23, REQ-ORC-O2-24, REQ-ORC-O2-15 | +| O2 Interface Test: O2 DMS ETSI NFV Profile Test | Instantiate NF Deployment test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.2.1 | +| | Terminate NF Deployment test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.2.2 | +| | Query NF Deployment test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.2.3 | +| | Heal NF Deployment test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.2.4 | +| | Scale NF Deployment test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.2.5 | +| | Change external connectivity of an NF Deployment test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.2.6 | + +| | | | | +|--|-----------------------------------------|------------------------------------------------|---------| +| | Change current NF Deployment package | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.2.7 | +| | Change NF Deployment flavour | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.2.8 | +| | Get alarm list test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.3.1 | +| | Notify test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.3.2 | +| | Acknowledge alarm test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.3.3 | +| | Create PM Job test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.4.1 | +| | Query/read PM job information test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.4.2 | +| | Delete a PM job test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.4.3 | +| | Create a threshold test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.4.4 | +| | Query/read threshold | [4] O-RAN.WG6.O2DMS- | 2.4.4.5 | + +| | | | +|-----------------------------------------------------|------------------------------------------------|---------| +| information test case | INTERFACE-ETSI-NFV-PROFILE | | +| Delete a threshold test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.4.6 | +| Sending performance related notifications test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.4.7 | +| Obtaining performance reports test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 2.4.4.8 | +| VNF instances REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.2 | +| Individual VNF instance REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.3 | +| Instantiate VNF task REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.4 | +| Terminate VNF task REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.5 | +| Notification test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.5 | +| Heal VNF task REST resource test case | [4] O-RAN.WG6.O2DMS- | 3.2.4.6 | + +| | | | | +|--|---------------------------------------------------------------|------------------------------------------------|----------| +| | | INTERFACE-ETSI-NFV-PROFILE | | +| | Scale VNF task REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.11 | +| | Scale VNF to Level task REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.12 | +| | Change external VNF connectivity task REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.13 | +| | Retry operation task REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.7 | +| | Rollback operation task REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.8 | +| | Fail operation task REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.9 | +| | Cancel operation task REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.2.4.10 | +| | Alarms REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.3.4 | +| | Individual alarm REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.3.4 | + +| | | | +|-------------------------------------------------------|------------------------------------------------|-------| +| Subscriptions REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.3.4 | +| Individual subscription REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.3.4 | +| Notification endpoint REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.3.4 | +| PM jobs REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.4.4 | +| Individual PM job REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.4.4 | +| Individual performance report REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.4.4 | +| Thresholds REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.4.4 | +| Individual threshold REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.4.4 | +| Notification endpoint REST resource test case | [4] O-RAN.WG6.O2DMS-INTERFACE-ETSI-NFV-PROFILE | 3.4.4 | + + + +# --- Annex (informative): Change History + +| Date | Revision | Description | +|------------|----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2022.06.20 | 00.00.00 | Create initial version of this specification, with skeleton. | +| 2022.11. | 00.08.00 | Update the skeleton add Notification API test, Incorporate the CRs of: <ul style="list-style-type: none"> <li>WRS-CR-O-RAN.WG6.O-Cloud Synchronization Test</li> </ul> | +| 2023.3.13 | 01.00.00 | Incorporate the CRs of: <ul style="list-style-type: none"> <li>DCM-2023.02.17.WG6-O-CLOUD-TEST-O2dms_ETSI_NFV_Test-v03</li> <li>WRS-CR-O-RAN.WG6.O-Cloud O2 Test_v02</li> </ul> | +| 2023.3.20 | 01.00 | Published as Final version 01.00 | +| 2023.5.23 | 01.00.01 | DCM-2023.04.19-O-RAN.WG6-O-CLOUD_CONF_TEST-Update_NFVProfile-v01.00 | +| 2023.8.1 | 01.01 | Published as Final version 01.01 | +| 2023.11.6 | 01.01.01 | Incorporate the CRs of: <ul style="list-style-type: none"> <li>DCM-2023.07.19-O-RAN.WG6-O-CLOUD_CONF_TEST-Add_testitems_NFVProfile-v01</li> <li>WindRiver-2023.08.07-O-RAN.WG6-O-CLOUD_CONF_TEST-amendment_O2IMSTest-v03</li> </ul> | +| 2023.11.20 | 02.00 | Resolve comments, Published as Final version 02.00 | +| 2024.3.16 | 02.00.01 | Incorporate the CRs of: <ul style="list-style-type: none"> <li>DCM-2023.12.XX-O-RAN.WG6-O-CLOUD_CONF_TEST-Add_testitems_NFVProfile-v01-testitem_for_resources_clarified</li> <li>LNVAO-2023.10.08-WG6-CR-0003-O-Cloud-CONF-Status-v06</li> <li>LNVAO-2024.02.06-WG6-CR-0003_O-Cloud-Conf-Synchronization-Update-v02</li> <li>LNVAO-2024.02.05-WG6-CR-0003_O-Cloud-Conf-Notification Update-v02</li> <li>LNVAO-2024.2.26-WG6-CR-0004-O-Cloud-CONF-Certification-Update-v01</li> </ul> | +| 2024.3.24 | 02.00.02 | Resolve approval comments | +| 2024.3.26 | 02.00.03 | Editorial updates to resolve approval comments | +| 2024.4.20 | 03.00 | Resolve comments, Published as Final version 03.00 | +| 2024.7.5 | 03.00.01 | Incorporate the CRs of: <ul style="list-style-type: none"> <li>DCM-2024.4.XX-O-RAN.WG6-O-CLOUD_CONF_TEST-catchup_with_latest_ETSI_NFV_v01.01</li> </ul> WRS-2024.5.XX-O-RAN.WG6-O-CLOUD_CONF_TEST-catchup_with_latest_O2_IMS_v01.00 | +| 2024.7.18 | 03.00.02 | Resolve comments | +| 2024.7.24 | 03.00.03 | Resolve comments about the Track Changes | +| 2024.7.30 | 04.00 | Resolve comments, Published as Final version 04.00 | +| 2024.10.08 | 04.00.01 | Incorporate the CRs of: <ul style="list-style-type: none"> <li>DCM-2024.8.21-O-RAN.WG6-O-CLOUD_CONF_TEST-catchup_with_v8_of_ETSI_NFV_Profile_v01.01</li> </ul> | + +| | | | +|------------|----------|----------------------------------------------------| +| 2024.10.9 | 04.00.02 | Resolve comments | +| 2024.11.6 | 04.00.03 | Resolve comments | +| 2024.11.28 | 04.00.04 | Editorial updates to resolve approval comments | +| 2024.12.3 | 04.00.05 | Editorial updates to resolve approval comments | +| 2024.12.9 | 04.01 | Resolve comments, Published as Final version 04.01 | \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/042c28a2dfae6b579cb83d1764a8d83a_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/042c28a2dfae6b579cb83d1764a8d83a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a8ee7367e8335fa359390a739bd52938255fb83e --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/042c28a2dfae6b579cb83d1764a8d83a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:afc1dec6a8808885794fcd74800cf510367bfbeaa5794e093ae3efdc41d3654b +size 4488 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/06adc378077e4ed08dfe58fe6e7875b7_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/06adc378077e4ed08dfe58fe6e7875b7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd87efe9690ed5191f154d6ed9294a8e37019b49 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/06adc378077e4ed08dfe58fe6e7875b7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a10a6ac342f352fe9fe9547e1714dae11f9d711cd9fd29039ea9ab454367a3f8 +size 4487 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/181eaeae477d703a58b50f906f2e276a_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/181eaeae477d703a58b50f906f2e276a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..61e9c160314cf4e7c662862f9ee90414dc05800f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/181eaeae477d703a58b50f906f2e276a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0f5a0d64f08682ab2e8401eb514d6f265f33ba8cd0698440a82a0f618ed5045b +size 33530 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/425a1b3e48c81a590e48256df11bff40_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/425a1b3e48c81a590e48256df11bff40_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..039d1960fdec75487a29cd36ef5fb667e4ed40af --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/425a1b3e48c81a590e48256df11bff40_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b139411c092d905b86a05497fc4df8b9507d320a9382d829fc634b52f706c79b +size 26886 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/64142c9582af48835a7a510d847ed156_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/64142c9582af48835a7a510d847ed156_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ca45342ec957602ad9f69ef4914d97a047acdd15 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/64142c9582af48835a7a510d847ed156_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4590a0c2273bf74d1e05fc451cecc01ee9182281d8306f275b7b5349bb068d85 +size 4524 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/7128081d42088f2fb870e3545ef91155_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/7128081d42088f2fb870e3545ef91155_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6a225e4db49472eb4307e078af1e3f00dac245be --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/7128081d42088f2fb870e3545ef91155_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e470dad2468876f0febefeaa3bc8d9024c5394707d85426c92cf04f8f3c3903 +size 5265 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/9925e212401a311aac8d0c9d04e6cd07_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/9925e212401a311aac8d0c9d04e6cd07_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7d84385b67611cb48460fe7def96f0441ea7b34f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/9925e212401a311aac8d0c9d04e6cd07_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:51fd51128421abb05f2cf483b62741fe3dd5f2a0265cfa399c993bab4fb44ca5 +size 4492 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/9d874845a81d999042d5cb09d46af101_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/9d874845a81d999042d5cb09d46af101_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..714753b6979b20cbb799452f982776310644557b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/9d874845a81d999042d5cb09d46af101_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:35e202cce901398848505d7544c8601b66e0255a9c75fd325741d50c8d2e006e +size 4525 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/9e4511cd9df465f012904f240d922f11_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/9e4511cd9df465f012904f240d922f11_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..17964a6d111e00c30e38fcb56676ac892a331b93 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/9e4511cd9df465f012904f240d922f11_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:672224bc04e3a063569b97063acdeca52c378c100fd37bc3d9faa22cc37af478 +size 4491 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/a9187dd9f72768b13988b10670106e67_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/a9187dd9f72768b13988b10670106e67_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4a2119d15241d2aecf46e095761025280e0bd3a4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/a9187dd9f72768b13988b10670106e67_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f6ef600120769342a37eb1e86170d0df90e0ad9302f07ff0964f6b74a67965e8 +size 4486 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/b76fa27025644d3cfb935468b9aa8c4f_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/b76fa27025644d3cfb935468b9aa8c4f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6038568aa9e0e8417bdf79fc95e4aa99e4aa93a2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/b76fa27025644d3cfb935468b9aa8c4f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9557416b247688b39d607834a35ae74e83bb0cf85f4fa51572fbafc278440be5 +size 35930 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/f93e2d9f0d772a11eb1fafa0f22ef4ee_img.jpg b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/f93e2d9f0d772a11eb1fafa0f22ef4ee_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b1e7a19ab102b86b1d63087fd9ff0c00cc5af58d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/f93e2d9f0d772a11eb1fafa0f22ef4ee_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2cd0d87f947272759005df78234dbdf8f9134baea1be8c153782fe97309ef4f8 +size 34445 diff --git a/marked/WG7/O-RAN.WG7.DSC.0-v04.00/raw.md b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..38e769e22ef84b5c517c2a2e144bc9f5ee7d2ec1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.DSC.0-v04.00/raw.md @@ -0,0 +1,918 @@ + + +# **O-RAN White Box Hardware Working Group Deployment Scenarios and Base Station Classes** --- + +Copyright © 2022 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +1 + +# --- Revision History + +| Date | Revision | Author | Description | +|------------|----------|--------|-------------------------------| +| 2022.07.22 | 04.00 | WG7 | Final Version for publication | +| 2021.07.08 | 03.00 | WG7 | Final version for publication | +| 2020.06.08 | 02.00 | WG7 | Final version for publication | +| 2019.10.29 | 01.00 | WG7 | Final Version for publication | + +--- + +2 + +3 + +# Contents + +| | | +|-------------------------------------------------------|----| +| Revision History ..... | 2 | +| Chapter 1    Introductory Material ..... | 5 | +| 1.1        Scope ..... | 5 | +| 1.2        References ..... | 5 | +| 1.3        Definitions and Abbreviations ..... | 5 | +| 1.3.1     Definitions ..... | 5 | +| 1.3.2     Abbreviations ..... | 6 | +| 1.4        Objectives ..... | 7 | +| Chapter 2    Deployment Scenarios ..... | 8 | +| 2.1        General ..... | 8 | +| 2.1.1     Base Station Architecture: Background ..... | 8 | +| 2.2        Deployment Scenarios ..... | 10 | +| 2.2.1     Indoor Picocell ..... | 10 | +| 2.2.2     Outdoor Picocell ..... | 11 | +| 2.2.3     Outdoor Microcell ..... | 12 | +| 2.2.4     Integrated access and backhaul (IAB) ..... | 14 | +| 2.2.5     Outdoor Macrocell (OMAC) ..... | 14 | +| 2.2.6     Fronthaul Gateway ..... | 15 | +| Chapter 3    Base Station Type Classification ..... | 17 | +| 3.1        General ..... | 17 | +| 3.2        Indoor ..... | 17 | +| 3.2.1     The split architecture ..... | 17 | +| 3.2.2     The integrated architecture ..... | 18 | +| 3.3        Outdoor ..... | 19 | +| 3.3.1     Picocell ..... | 19 | +| 3.3.2     Microcell ..... | 20 | +| 3.3.3     Integrated access and backhaul (IAB) ..... | 23 | +| 3.3.4     Macrocell ..... | 23 | +| Chapter 4    Key performance indicators ..... | 25 | +| 4.1        Peak data rate ..... | 25 | +| 4.2        Peak spectral efficiency ..... | 25 | +| 4.3        Bandwidth ..... | 25 | +| 4.4        Control plane latency ..... | 26 | +| 4.5        User plane latency ..... | 26 | +| 4.6        Mobility ..... | 26 | + +# Tables + +| | | +|-------------------------------------------------------------------------------------------------|----| +| Table 2.2.1-1: Attributes for FR1 Indoor Picocell ..... | 11 | +| Table 2.2.2-1: Attributes for FR1 Outdoor Picocell ..... | 11 | +| Table 2.2.2-2: Attributes for FR2 Outdoor Picocell ..... | 12 | +| Table 2.2.3-1: Attributes for FR1 Outdoor Microcell ..... | 12 | +| Table 2.2.3-2: Attributes for FR2 Outdoor Microcell ..... | 13 | +| Table 2.2.4-1: Attributes for Integrated Access and Backhaul ..... | 14 | +| Table 2.2.5-1: Attributes for FR1 Outdoor Macrocell ..... | 15 | +| Table 2.2.6-1: Attributes for Fronthaul Gateway ..... | 16 | +| Table 2.2.6-1: Base Station Classes for Deployment Scenarios ..... | 17 | +| Table 3.2.1-1: Descriptions of Attributes for the Indoor Picocell Split Architecture ..... | 18 | +| Table 3.2.2-1: Descriptions of Attributes for the Indoor Picocell Integrated Architecture ..... | 19 | +| Table 3.3.1-1: Descriptions of Attributes for the Outdoor Picocell Architecture ..... | 19 | +| Table 3.3.2-1: Descriptions of Attributes for the FR1 Outdoor Microcell Architecture ..... | 20 | +| Table 3.3.2-2: Descriptions of Attributes for the FR1 Enterprise Microcell Architecture ..... | 21 | + +| | | +|------------------------------------------------------------------------------------------------------------|----| +| Table 3.3.2-3: Descriptions of Attributes for the FR1 Outdoor Microcell with All-In-One Architecture ..... | 22 | +| Table 3.3.2-4: Descriptions of Attributes for the FR2 Outdoor Microcell Architecture..... | 22 | +| Table 3.3.3-1: Descriptions of Attributes for the IAB Architecture ..... | 23 | +| Table 3.3.4-1: Descriptions of Attributes for the FR1 Outdoor Macrocell Architecture ..... | 24 | + +# Figures + +| | | +|----------------------------------------------------------------------------------------------------------|----| +| Figure 2.1.1-1: Base Station Architecture deploying lower level split without protocol translation ..... | 9 | +| Figure 2.1.1-2: Base Station Architecture deploying lower level split with protocol translation ..... | 9 | +| Figure 2.1.1-3: Base Station with Integrated Architecture ..... | 10 | +| Figure 2.1.1-4: Base Station with All-in-one Architecture..... | 10 | +| Figure 2.2.4-1: IAB integrated architecture..... | 14 | + +# Chapter 1 Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG7 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e., technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. This variable is for internal WG7 use only. + +The present document specifies operator requirements for scenarios, use cases and base station classes for O-RAN white box hardware, and identifies typical deployment scenarios associated with carrier frequency, inter-site distance, and other key parameters and attributes. + +In the main body of this specification (in any “chapter”) the information contained therein is informative, unless explicitly described as normative. Information contained in an “Annex” to this specification is always informative unless otherwise marked as normative. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document. + +- [1] 3GPP TR 21.905, “Vocabulary for 3GPP Specifications” +- [2] 3GPP TR 38.104, “NR; Base Station (BS) radio transmission and reception” +- [3] 3GPP TR 38.473, “NG-RAN F1 Application Protocol (F1AP)” +- [4] 3GPP TR 38.340, “NR; Backhaul Adaptation Protocol” +- [5] 3GPP TR 38.874, “Study on Integrated Access and Backhaul” +- [6] O-RAN.WG7.CUS.0-v02.00, O-RAN WG4 Control, User and Synchronization Specification + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in [1]. For the base station classes of Pico, Micro and Macro, the definitions are given in [2]. + +**All-In-One architecture:** In the all-in-one architecture, the O-RU, O-DU and O-CU are implemented on one platform. There is no need for neither fronthaul interface between O-RU and O-DU nor F1 interface between O-DU and O-CU. + +**Carrier Frequency:** Central frequency of the cell. + +**F1 interface:** The open interface between O-CU and O-DU, the definition is given in O-RAN WG5. Refer to [3]. + +**IAB-donor:** RAN node which provides UE's interface to core network and wireless backhauling functionality to IAB nodes. Refer to [4] and [5]. + +**IAB-node:** AN node that supports wireless access to UEs and wirelessly backhauls the access traffic. Refer to [4] and [5]. + +**Integrated architecture:** In the integrated architecture, the O-RU and O-DU are implemented on one platform. Each O-RU and RF frontend is associated with one LLS-DU. They are then aggregated to O-CU, connected by F1 interface. + +**Layout:** Network framework. + +**Mobile-Termination (MT):** MT is the UE function in each IAB node that allows it to communicate with parent node. Refer to [4] and [5]. + +**Split architecture:** The O-RU and O-DU are physically separated from one another in this architecture. A fronthaul gateway may aggregate multiple O-RUs to one O-DU. O-DU, fronthaul gateway and O-RUs are connected by fronthaul interfaces. + +**System bandwidth:** The bandwidth in which a Base Station transmits and receives multiple carriers and/or RATs simultaneously. + +**Transmission Reception Point (TRxP):** Antenna array with one or more antenna elements available to the network located at a specific geographical location for a specific area. + +**Layer:** This term refers to deployment layers. A single layer has no overlay cell. Two layers refers to a layout where the second layer maybe deployed as underlaying cell w.r.t the primary cell. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in [1] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, in [1]. + +| | | +|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 7-2x | Fronthaul interface split option as defined by O-RAN WG4 | +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth-Generation Mobile Communications | +| AC | Alternating Current | +| BB | Baseband | +| BDS | BeiDou Navigation Satellite System | +| bps | Bits Per Second | +| BS | Base Station | +| CU | Centralized Unit as defined by 3GPP | +| DC | Direct Current | +| DL | Downlink | +| DRX | Discontinuous Reception | +| DU | Distributed Unit as defined by 3GPP | +| EDGE | Enhanced Data rates for GSM Evolution | +| EIRP | Equivalent Isotropic Radiated Power | +| eMBB | Enhanced Mobile Broadband | +| FDD | Frequency Division Duplex | +| FH | Fronthaul | +| FHGW <sub>x→y</sub> | Fronthaul gateway that can translate FH protocol from an O-DU with split option x to an O-RU with split option y, with currently available option 7-2x→8. | +| FHM | Fronthaul gateway with no FH protocol translation, supporting an O-DU with split option x and an O-RU with split option x, with currently available options 6→6, 7-2x→7-2x and 8→8. | +| Gbps | Gigabits Per Second | +| GNSS | Global Navigation Satellite System | +| GSM | Global System for Mobile communications | +| HAR | Hardware Architecture and Requirement | +| HRD | Hardware Reference Design | +| IAB | Integrated Access and Backhaul | +| IEEE | Institute of Electrical and Electronics Engineers | +| ISD | Inter-Site Distance | +| KPI | Key Performance Indicator | +| MAC | Medium Access Control | +| MEC | Mobile/Multi-access Edge Computing | +| MIMO | Multiple Input Multiple Output | + +| | | | +|----|-------------------|----------------------------------------------------------------------------------------------------| +| 1 | Ms | Milliseconds | +| 2 | MT | Mobile-Termination | +| 3 | MU-MIMO | Multiple User MIMO | +| 4 | NB-IoT | Narrow Band Internet of Things | +| 5 | NR | New Radio | +| 6 | O-CU | O-RAN Centralized Unit as defined by O-RAN | +| 7 | O-DU | O-RAN Distributed Unit as defined by O-RAN and having fronthaul split option 7-2x | +| 8 | O-DU <sub>x</sub> | A specific O-RAN Distributed Unit having fronthaul split option x where x may be 6, 7-2x (as | +| 9 | | defined by WG4) or 8 | +| 10 | O-RAN | Open-Radio Access Network | +| 11 | O-RU | O-RAN Radio Unit as defined by O-RAN and having fronthaul split option 7-2x | +| 12 | O-RU <sub>x</sub> | A specific O-RAN Radio Unit having fronthaul split option x, where x is 6, 7-2x (as defined by | +| 13 | | WG4) or 8, and which is used in a configuration where the fronthaul interface is the same at the | +| 14 | | O-DU <sub>x</sub> | +| 15 | O-RU <sub>y</sub> | A specific O-RAN Radio Unit having fronthaul split option y, where y is 7-2x (as defined by | +| 16 | | WG4) or 8, and which is used in a configuration where the fronthaul interface at O-RU is different | +| 17 | | than that at O-DU <sub>x</sub> | +| 18 | PDCP | Packet Data Conversion Protocol | +| 19 | POE | Power Over Ethernet | +| 20 | QoE | Quality of Experience | +| 21 | QoS | Quality of Service | +| 22 | RAN | Radio Access Network | +| 23 | RAT | Radio Access Technology | +| 24 | Rel-x | Release number: where x is the actual release number | +| 25 | RF | Radio Frequency | +| 26 | RFFE | RF Front End | +| 27 | RLC | Radio Link Control | +| 28 | RRC | Radio Resource Control | +| 29 | RRM | Radio Resource Management | +| 30 | RU | Radio Unit as defined by 3GPP | +| 31 | Rx | Receiver | +| 32 | SDAP | Service Data Adaptation Protocol | +| 33 | SDU | Service Data Unit | +| 34 | SON | Self Organized Network | +| 35 | SU-MIMO | Single User MIMO | +| 36 | TDD | Time division Duplex | +| 37 | TR | Technical Report | +| 38 | TRP | Transmission Reception Point | +| 39 | TS | Technical Specification | +| 40 | Tx | Transmitter | +| 41 | UE | User Equipment | +| 42 | UL | Uplink | +| 43 | UPF | User Plane Function | +| 44 | URLLC | Ultra-Reliable and Low Latency Communications | +| 45 | μsec | Microseconds | +| 46 | WG | Working Group | + +## 1.4 Objectives + +Openness is one of the key principles for O-RAN Alliance. To take full advantage of the economies of scale offered by an open computing platform approach, O-RAN Alliance reference designs will specify high performance, spectral and energy efficient white-box base station hardware. Reference platforms support a decoupled approach and offer detailed schematics for hardware and software architecture to enable both the O-DU<sub>x</sub> and O-RU<sub>x</sub>. + +The promotion of white box hardware is a potential way to reduce the cost of 5G deployment, which will benefit both the operators and vendors. The objective of the white-box hardware workgroup is to specify and release a complete reference design, thereby fostering a decoupled software and hardware platform. Currently, there is no open base station reference design architecture, making it impossible for operators and vendors to develop software for optimizing their network operation in various application scenarios. Therefore, it is further envisioned that the group will do research on all related content to build valuable reference designs. + +The main objective of this document is to aid in development of base station HW architecture and requirements specification, and consequently, the HW reference design specification for white boxes based on the identified deployment scenarios within this specification. + +# Chapter 2 Deployment Scenarios + +## 2.1 General + +In this chapter we present the deployment scenarios as identified by the operator group within O-RAN. The detailed reference base station specification for each identified scenario and their classifications case will be provided in the following chapters. The use case scenarios will include: + +- eMBB (enhanced Mobile BroadBand) +- URLLC (Ultra-Reliable and Low Latency Communications) + +### 2.1.1 Base Station Architecture: Background + +For any deployment scenarios, the base station architecture falls into three categories: 1) Split Architecture, 2) Integrated architecture or 3) All-in-one architecture. The split architecture can be deployed in two ways: 1) O-CU and O-DU<sub>x</sub> are connected via an optional fronthaul multiplexer (FHM) or a switch to multiple O-RU<sub>x</sub>/optional cascaded O-RU<sub>x</sub> (See Figure 2.1.1-1 or Figure 2.1.1-2) O-CU and O-DU<sub>x</sub> are connected via a fronthaul gateway (FHGW<sub>x→y</sub>) to multiple O-RU<sub>y</sub>s (See Figure 2.1.1-2). Note that the term optional is used to indicate there may be a deployment case where an FHM, or a switch, or a FHGW may not be used for a specific deployment scenario. The O-CU shall be located at the data center and the O-DU can be placed either at the data center or at the cell site. O-DUs located at the cell site can also be placed in a ruggedized cabinet for outdoor deployments. + +Depending on how much intelligence one requires to place in O-RU<sub>x</sub> or O-DU<sub>x</sub>, there will be a functional split that splits up functions of PHY layer between O-DU<sub>x</sub> and O-RU<sub>x</sub>. O-CU and O-DU<sub>x</sub> may be designed to be integrated into one hardware box or as two separate boxes. For downlink, depending on the deployed architecture, FHM or FHGW broadcasts the data to all the O-RU<sub>x</sub>s or O-RU<sub>y</sub>s, respectively. For uplink, it shall combine all the uplink data from subtending O-RU<sub>x</sub>s or O-RU<sub>y</sub>s according to the cell sets. Within working group 7 (and therefore all specifications stemming from it), all fronthaul interfaces are based on the following three criteria. A fronthaul interface that meets one of the following criteria can be defined as an open fronthaul interface: + +1. O-RAN WG4 (open fronthaul interface group) released interfaces; or +2. O-RAN approved publicly (e.g., small cell forum or etc.) available external interfaces; or +3. Fronthaul interfaces made available and published as part of an O-RAN approved WG7 reference design. + +Within this specification, "dashed boxes" are representative of white boxes. In some cases, the figures use specific O-DU<sub>x</sub> and O-RU<sub>y</sub> or O-DU<sub>x</sub> and O-RU<sub>x</sub> terminologies to demonstrate an example split option configuration. The first case is where the FHGW<sub>x→y</sub> translates split option x from an O-DU<sub>x</sub> to split option y for an O-RU<sub>y</sub>. Currently, the following split options with a fronthaul translation and the associated terminologies will be used throughout all WG7 specifications: + +- 1- O-DU<sub>7-2x</sub> ↔ FHGW<sub>7-2x→8</sub> ↔ O-RU<sub>8</sub> + +In the case where the fronthaul gateway does not perform a protocol translation, the terminology FHM O-DU<sub>x</sub> and O-RU<sub>x</sub> are used, and the following split options and the associated terminologies will be used throughout all specifications: + +- 1- O-DU<sub>6</sub> ↔ FHM/Switch ↔ O-RU<sub>6</sub> +- 2- O-DU<sub>7-2x</sub> ↔ FHM/Switch ↔ O-RU<sub>7-2x</sub> +- 3- O-DU<sub>8</sub> ↔ FHM/Switch ↔ O-RU<sub>8</sub> + +![Figure 2.1.1-1: Base Station Architecture deploying lower level split without protocol translation. The diagram shows an O-CU and O-DU_x connected via an F1 Interface. This pair is enclosed in a dashed box with a note: 'O-CU & O-DU_x may/may not be integrated into one Whitebox'. This box is connected to an 'FHM Or Switch (Optional)' block via an 'FH Interface_x'. The 'FHM Or Switch' block is then connected to multiple O-RU_x blocks via 'FH Interface_x'. One O-RU_x block is also connected to another O-RU_x block via an 'FH Interface_x Via Fiber Bypass'.](181eaeae477d703a58b50f906f2e276a_img.jpg) + +Figure 2.1.1-1: Base Station Architecture deploying lower level split without protocol translation. The diagram shows an O-CU and O-DU\_x connected via an F1 Interface. This pair is enclosed in a dashed box with a note: 'O-CU & O-DU\_x may/may not be integrated into one Whitebox'. This box is connected to an 'FHM Or Switch (Optional)' block via an 'FH Interface\_x'. The 'FHM Or Switch' block is then connected to multiple O-RU\_x blocks via 'FH Interface\_x'. One O-RU\_x block is also connected to another O-RU\_x block via an 'FH Interface\_x Via Fiber Bypass'. + +**Figure 2.1.1-1: Base Station Architecture deploying lower level split without protocol translation** + +![Figure 2.1.1-2: Base Station Architecture deploying lower level split with protocol translation. The diagram shows an O-CU and O-DU_x connected via an F1 Interface. This pair is enclosed in a dashed box with a note: 'O-CU & O-DU_x may/may not be integrated into one Whitebox'. This box is connected to an 'FHGW_{x \to y}' block via an 'FH Interface_x'. The 'FHGW' block is then connected to multiple O-RU_y blocks via 'FH Interface_y'. One O-RU_y block is also connected to another O-RU_y block via an 'FH Interface_x Via Fiber Bypass'.](b76fa27025644d3cfb935468b9aa8c4f_img.jpg) + +Figure 2.1.1-2: Base Station Architecture deploying lower level split with protocol translation. The diagram shows an O-CU and O-DU\_x connected via an F1 Interface. This pair is enclosed in a dashed box with a note: 'O-CU & O-DU\_x may/may not be integrated into one Whitebox'. This box is connected to an 'FHGW\_{x \to y}' block via an 'FH Interface\_x'. The 'FHGW' block is then connected to multiple O-RU\_y blocks via 'FH Interface\_y'. One O-RU\_y block is also connected to another O-RU\_y block via an 'FH Interface\_x Via Fiber Bypass'. + +**Figure 2.1.1-2: Base Station Architecture deploying lower level split with protocol translation** + +Note that within WG7 and therefore all specifications stemming from it, O-DU<sub>7-2x</sub> and O-RU<sub>7-2x</sub> refer to O-DU and O-RU as defined by WG4. + +Since in split architecture O-DU<sub>x</sub> and O-RU<sub>x</sub> are physically separated from one another by the FH interface, therefore, depending on the split option, certain functions of base stations may either be performed in the O-DU<sub>x</sub> or O-RU<sub>x</sub>. There are 8 different FH split options available (as defined by 3GPP); however, currently within WG7 the following split options are considered (as requested by operators for their deployment scenarios): + +1. Split option 6: All PHY functions will reside in O-RU<sub>x</sub> while MAC functions will be performed in O-DU<sub>x</sub>. In other words, only un-coded user data is on FH. In this case the terminology O-DU<sub>6</sub> and O-RU<sub>6</sub> is used. +2. Split option 7-2x, the PHY is split into High and Low PHY functions; where High PHY functions (coding, rate matching, scrambling, modulations and layer mapping) are performed in O-DU<sub>x</sub> while O-RU<sub>x</sub> performs the Low PHY functions (precoding, remapping, digital beamforming, IFFT and CP insertion). All I/Q samples are in frequency domain. In this case the terminology O-DU<sub>7-2x</sub> and O-RU<sub>7-2x</sub> is used. +3. Split Option 8: All PHY functions are performed in O-DU<sub>x</sub>. This means that O-RU<sub>x</sub> function is limited to RF to baseband conversion and vice versa. The I/Q samples on FH interface are in time-domain. In this case the terminology O-DU<sub>8</sub> and O-RU<sub>8</sub> is used. + +In some cases, when a FHM/Switch/FHGW is not used, a second O-RU may be cascaded to the first O-RU via the FH interface. In this way, the coverage area may be further expanded. The FH interface between the two cascaded O-RUs shall be the same as the FH interface between the O-DU and the first O-RU. For downlink, the first O-RU copies the data received from the O-DU, then sends it to the second O-RU. For uplink, the first O-RU combines the uplink data from the second O-RU, and then sends it to the O-DU. + +Integrated Architecture is defined as where O-DU<sub>x</sub> and O-RU<sub>x</sub> are physically located in one hardware box and as such no FH interface is required to connect them. Figure 2.1.1-3 illustrates the base station having an integrated architecture. For the integrated architecture, open F1 interface is between O-CU and O-DU<sub>x</sub> (which is discussed in O-RAN WG5). + +![Figure 2.1.1-3: Base Station with Integrated Architecture. The diagram shows a dashed box labeled 'O-CU' connected via a double-headed arrow labeled 'F1 Interface' to a solid box labeled 'Switch'. The 'Switch' is then connected via double-headed arrows to three dashed boxes, each labeled 'O-DUx & O-RUx', with vertical ellipsis dots between the middle and bottom boxes.](425a1b3e48c81a590e48256df11bff40_img.jpg) + +Figure 2.1.1-3: Base Station with Integrated Architecture. The diagram shows a dashed box labeled 'O-CU' connected via a double-headed arrow labeled 'F1 Interface' to a solid box labeled 'Switch'. The 'Switch' is then connected via double-headed arrows to three dashed boxes, each labeled 'O-DUx & O-RUx', with vertical ellipsis dots between the middle and bottom boxes. + +**Figure 2.1.1-3: Base Station with Integrated Architecture** + +All-in-one Architecture is defined as where O-CU, O-DU<sub>x</sub> and O-RU<sub>x</sub> are physically located in one hardware box, as such no FH interface and F1 interface are required to connect them. Figure 2.1.1-4 illustrates the base station having an all-in-one architecture. The functions of O-CU, O-DU<sub>x</sub> and O-RU<sub>x</sub> are included in baseband unit followed by RF Processing unit. + +![Figure 2.1.1-4: Base Station with All-in-one Architecture. The diagram shows a single dashed box labeled 'BB & RF'.](7128081d42088f2fb870e3545ef91155_img.jpg) + +Figure 2.1.1-4: Base Station with All-in-one Architecture. The diagram shows a single dashed box labeled 'BB & RF'. + +**Figure 2.1.1-4: Base Station with All-in-one Architecture** + +## 2.2 Deployment Scenarios + +Deployment scenarios for use-cases described in section 2.1 will be provided in this section. These scenarios are based on reported scenarios as reported by service providers. Scenarios in this specification do not preclude any other scenario. Other scenarios may be added as a change request to this specification. + +### 2.2.1 Indoor Picocell + +The indoor deployment scenario is mainly for small coverage per site within buildings, open spaces, etc. A key characteristic of this deployment scenario is consistent indoor user experience, high user density within buildings an open office and high capacity. + +Some of its attributes are listed in Table 2.2.1-1 below. + +**Table 2.2.1-1: Attributes for FR1 Indoor Picocell** + +| Attributes | Values or Assumptions | +|--------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------| +| Carrier Frequency <sup>(a)</sup> | n2, n4, n5, n13, n41, n48, n66, n77, n78, n79 | +| System Bandwidth <sup>(b)</sup> | Up to 100MHz (DL+UL) | +| Cell Layout | Single layer | +| Mounting options | Above ceiling (Plenum rated) and/or on the wall; Open Office | +| ISD | 20m | +| BS MIMO Configuration <sup>(c)</sup> | 2TX/2RX or 4TX/4RX | +| Output power | 2TX/2RX: ≤27dBm (per channel) Conducted Output Power;<br>4TX/4RX: ≤24dBm (per channel) Conducted Output Power | +| Coverage <sup>(d)</sup> | Omni | +| Key Architecture Features | Split Architecture (split options: 6, 7-2x and 8 are supported and each option is further described in Section 2.1.1) and Integrated Architecture. | + +Notes: + +(a) The options noted here are for the first stage, and do not preclude the study of other spectrum options, e.g. mmWave. Certain technology bands have specific regulatory requirements that must be followed + +(b) The system bandwidth is the total bandwidth typically assumed to derive the values for some KPIs such as area traffic capacity and user experienced data rate. It is also allowed to have an aggregated bandwidth totalling up to the system bandwidth. "DL + UL" refers to either of the following two cases: + +- FDD with symmetric bandwidth allocations between DL and UL. +- TDD with the aggregated system bandwidth used for either DL or UL via switching in time-domain. + +(c) The options noted here are typical configurations. + +(d) Other options (e.g. Sectorized with directional antenna), are not precluded. + +### 2.2.2 Outdoor Picocell + +Two scenarios have been identified for picocell outdoor scenario: 1) FR1 and 2) FR2. While both deployment scenarios have integrated architecture (See Figure 2.1.1-3), they do have different attributes and as such they have been listed separately in Table 2.2.2-1 and Table 2.2.2-2. + +**Table 2.2.2-1: Attributes for FR1 Outdoor Picocell** + +| Attributes | Values or Assumptions | +|--------------------------------------|-----------------------------------------------------------------------------------------| +| Carrier Frequency <sup>(a)</sup> | n2, n4, n5, n13, n41, n48, n66, n77, n78, n79 | +| System Bandwidth <sup>(b)</sup> | ≥100 MHz (DL+UL) | +| Cell Layout | single layer<br>Two layers:<br>- Macro or Micro layer<br>- Pico layer: random locations | +| Mounting Options | Rooftop, Side of Building (wall), Pole, under overhang | +| ISD | 200 m | +| BS MIMO Configuration <sup>(c)</sup> | Up to 4TX/4RX | +| Output Power | ≥35 dBm EIRP | +| Coverage <sup>(d)</sup> | Omni | +| Key Architecture Features | Integrated Architecture. See Figure 2.1.1-3. | + +Notes: + +(a) The options noted here are for the first stage, and do not preclude the study of other spectrum options, e.g. mmWave. Certain technology bands have specific regulatory requirements that must be followed + +(b) The system bandwidth is the total bandwidth typically assumed to derive the values for some KPIs such as area traffic capacity and user experienced data rate. It is also allowed to have an aggregated bandwidth totalling up to the system bandwidth. "DL + UL" refers to either of the following two cases: + +- FDD with symmetric bandwidth allocations between DL and UL. +- TDD with the aggregated system bandwidth used for either DL or UL via switching in time-domain. + +(c) The options noted here are typical configurations. + +(d) Other options (e.g., Sectorized with directional antenna), are not precluded. + +**Table 2.2.2-2: Attributes for FR2 Outdoor Picocell** + +| Attributes | Values or Assumptions | +|--------------------------------------|-----------------------------------------------------------------------------------------| +| Carrier Frequency <sup>(a)</sup> | n257, n258, n260, n261 | +| System Bandwidth <sup>(b)</sup> | up to 800 MHz (DL+ UL) | +| Layout | single layer<br>Two layers:<br>- Macro or Micro layer<br>- Pico layer: random locations | +| Mounting Options | Rooftop, Side of Building (wall), Pole, under overhang | +| ISD | 200 m | +| BS MIMO Configuration <sup>(c)</sup> | Up to 4TX/4RX | +| Output Power | 50-55 dBm EIRP | +| Coverage <sup>(d)</sup> | Omni | +| Key Architecture Features | Integrated Architecture. See Figure 2.1.1-3 . | + +Notes: + +(a) The options noted here are for the first stage, and do not preclude the study of other spectrum options, e.g. mmWave. Certain technology bands have specific regulatory requirements that must be followed + +(b) The system bandwidth is the total bandwidth typically assumed to derive the values for some KPIs such as area traffic capacity and user experienced data rate. It is also allowed to have an aggregated bandwidth totalling up to the system bandwidth. "DL + UL" refers to either of the following two cases: + +- FDD with symmetric bandwidth allocations between DL and UL. +- TDD with the aggregated system bandwidth used for either DL or UL via switching in time-domain. + +(c) The options noted here are typical configurations. + +(d) Other options (e.g. Sectorized with directional antenna) are not precluded. + +### 2.2.3 Outdoor Microcell + +There are two deployment scenario proposals for outdoor microcell by operators' group. The architectures for both microcell deployment scenarios are the same and it is illustrated in Figure 2.1.1-1 and Figure 2.1.1-2, except that outdoor microcell have all-in-one architecture (See Figure 2.1.1-4). + +The base station attributes for FR1 are listed in Table 2.2.3-1. The attributes for FR2 microcell outdoor deployment scenario are listed in Table 2.2.3-2. It shall be noted that all frequencies are given as NR operating bands in either in FR1 or FR2. + +**Table 2.2.3-1: Attributes for FR1 Outdoor Microcell** + +| Attributes | Values or Assumptions | | +|------------|-----------------------|----------------------| +| | Outdoor Microcell | Enterprise Microcell | + +| | | | +|----------------------------------|-----------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------| +| Carrier Frequency <sup>(a)</sup> | n2, n4, n5, n13, n41, n48, n66, n77, n78, n79 | n41, n78 | +| System Bandwidth <sup>(b)</sup> | Up to 200MHz (DL+UL) | Up to 200MHz (DL+UL) | +| Cell Layout | single layer<br>Two layers:<br>- Macro or Micro layer<br>- Pico layer: random locations | single layer<br>Two layers:<br>- Macro or Micro layer<br>- Pico layer: random locations | +| Mounting Options | Rooftop, Side of Building (wall), Pole | Rooftop, Side of Building (wall), Pole | +| ISD | 700 m | 500m<br>(distance between the two cascaded O-RUs: Up to 10km) | +| BS MIMO Layers <sup>(c)</sup> | Up to 16TX/16RX | Up to 8TX/8RX | +| Output Power | < 61 dBm EIRP | < 64 dBm EIRP | +| Coverage <sup>(d)</sup> | Omni/Sectorized | Omni/Sectorized | +| Key Architecture Features | Split architecture (O-RAN WG4 split option 7-2x) and all-in-one architecture. | Split architecture (O-RAN WG4 split option 7-2x, or split option 8). | + +Notes: + +(a) The options noted here are for the first stage, and do not preclude the study of other spectrum options, e.g., mmWave. Certain technology bands have specific regulatory requirements that must be followed + +(b) The system bandwidth is the total bandwidth typically assumed to derive the values for some KPIs such as area traffic capacity and user experienced data rate. It is also allowed to have an aggregated bandwidth totalling up to the system bandwidth. "DL + UL" refers to either of the following two cases: + +- FDD with symmetric bandwidth allocations between DL and UL. +- TDD with the aggregated system bandwidth used for either DL or UL via switching in time-domain. + +(c) The options noted here are typical configurations. + +(d) Other options (e.g. Sectorized with directional antenna) are not precluded. + +**Table 2.2.3-2: Attributes for FR2 Outdoor Microcell** + +| Attributes | Values or Assumptions | +|----------------------------------|-----------------------------------------------------------------------------------------| +| Carrier Frequency <sup>(a)</sup> | n257, n258, n260, n261 | +| System Bandwidth <sup>(b)</sup> | Up to 1.2 GHz (DL+UL) | +| Cell Layout | single layer<br>Two layers:<br>- Macro or Micro layer<br>- Pico layer: random locations | +| Mounting Options | Rooftop, Side of Building (wall), Pole | +| ISD | 200 m | +| BS MIMO Layers <sup>(c)</sup> | Up to 4TX/4RX | +| Output Power | >60 dBm EIRP | +| Coverage <sup>(d)</sup> | Sectorized | +| Key Architecture Features | Split Architecture (O-RAN WG4 split option 7-2x). | + +Notes: + +(a) The options noted here are for the first stage, and do not preclude the study of other spectrum options, e.g., mmWave. Certain technology bands have specific regulatory requirements that must be followed + +(b) The system bandwidth is the total bandwidth typically assumed to derive the values for some KPIs such as area traffic capacity and user experienced data rate. It is also allowed to have an aggregated bandwidth totalling up to the system bandwidth. "DL + UL" refers to either of the following two cases: + +- FDD with symmetric bandwidth allocations between DL and UL. +- TDD with the aggregated system bandwidth used for either DL or UL via switching in time-domain. + +(c) The options noted here are typical configurations. + +(d) Other options (e.g. Sectorized with directional antenna) are not precluded. + +### 2.2.4 Integrated access and backhaul (IAB) + +A key benefit of Integrated Access and Backhaul (IAB) is enabling flexible and very dense deployment of NR cells without densifying the transport network proportionately. Various deployment scenarios have been proposed including support for outdoor small cell deployments, indoors, or even mobile relays (e.g., on buses or trains). The IAB architecture is shown in Figure 2.2.4-1 below. IAB specifications as well as F1\* interface can be found in [3]. + +![Figure 2.2.4-1: IAB integrated architecture diagram. The diagram shows an O-CU connected to an IAB Node (O-DUx/O-RUx) via an Open F1/E2 Interface. The IAB Node is connected to two IAB Relays (MT and O-DUx/O-RUx) via an Open F1* or adapt Interface. Each IAB Relay is connected to another IAB Relay (MT and O-DUx/O-RUx) via a Small Form Factor interface.](f93e2d9f0d772a11eb1fafa0f22ef4ee_img.jpg) + +Figure 2.2.4-1: IAB integrated architecture diagram. The diagram shows an O-CU connected to an IAB Node (O-DUx/O-RUx) via an Open F1/E2 Interface. The IAB Node is connected to two IAB Relays (MT and O-DUx/O-RUx) via an Open F1\* or adapt Interface. Each IAB Relay is connected to another IAB Relay (MT and O-DUx/O-RUx) via a Small Form Factor interface. + +**Figure 2.2.4-1: IAB integrated architecture.** + +Some of the attributes of integrated access and backhaul are listed in Table 2.2.4-1. + +**Table 2.2.4-1: Attributes for Integrated Access and Backhaul** + +| Attributes | Values or assumptions | +|------------------------------------------|---------------------------------------------------------------------------| +| Carrier Frequency <sup>(a)</sup> | n257, n258, n260, n261 | +| System Bandwidth <sup>(b)</sup> | n257, n258, n261: 100 – 400 MHz (DL+ UL),<br>n260: 400 – 800 MHz (DL+ UL) | +| Cell Layout | Single or HetNet, single hop to multi-hop | +| Mounting Options | Rooftop, Side of Building (wall), Pole, under overhang, vehicle (bus) | +| ISD | 200 m | +| BS MIMO Layers <sup>(c)</sup> | Up to 4TX/4RX | +| Output Power | 50-55 dBm EIRP, to be confirmed after 3GPP RAN4 confirmation | +| Coverage <sup>(d)</sup> | Omni | +| Key Architecture Features <sup>(e)</sup> | Integrated Architecture (O-DU + MT functionality) | + +Notes: + +(a) The options noted here is for the first stage, and do not preclude the study of other spectrum options. + +(b) "DL + UL" refers to either of the following two cases: + +- FDD with symmetric bandwidth allocations between DL and UL. +- TDD with the aggregated system bandwidth used for either DL or UL via switching in time-domain. + +(c) The options noted here are typical configurations. + +(d) Other options (e.g., Sectorized with directional antenna) are not precluded. + +(e) MT is the UE function in each IAB node that allows it to communicate with parent node. + +### 2.2.5 Outdoor Macrocell (OMAC) + +The outdoor deployment scenario is mainly for macro coverage for roads, buildings, open spaces, etc. in rural, semi-urban and urban areas. A key characteristic of this deployment scenario is consistent 5G experience and seamless mobility. + +The Macrocell configuration is defined below for split option 7-2x with the O-DU at the cell site or at the data center and can be an integrated architecture (Split 2 architecture – Integrated O-DU and O-RU). + +Some of its attributes are listed in Table 2.2.5-1 below. + +The outdoor massive MIMO radio unit deployment scenario is mainly used for improved coverage and capacity solution utilizing both spatial multiplexing and beamforming. It offers higher capacity and better user experience when compared to traditional 8T8R radio. Massive MIMO O-RU includes active antenna array system with higher number of radio RF chains. This can be deployed for high traffic roads, high rise buildings, open spaces, etc. and in rural, urban and dense urban areas. + +The massive MIMO radio configuration is defined below for split option 7-2x with the O-DU at the cell site or at the data center. The massive MIMO specific attributes are listed in Table 2.2.5-1 below. Massive MIMO will have separate chapters in OMAC HAR and HRD documents to describe the high- and low-level architectures in detail, respectively + +**Table 2.2.5-1: Attributes for FR1 Outdoor Macrocell** + +| Attributes | Values or Assumptions | +|----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Carrier Frequency <sup>(a)</sup> | n26, n29, n41, n66, n70, n71, n77, n78, B1/n1, B3/n3, B7/n7, n78 CEPT(e). | +| System Bandwidth <sup>(b)</sup> | up to 400 MHz TDD; up to 205 MHz FDD | +| Cell Layout | up to 8T8R O-RU: up to 4-layer MIMO<br>16T16R to 64T64R Massive MIMO O-RU: up to 16-layer MIMO (DL) and;<br>up to 12-layer MIMO (UL) | +| Mounting Options | Rooftop, Towers, Side of Buildings | +| ISD | Variable | +| BS MIMO Layers <sup>(c)</sup> | Up to 8T8R<br>For Massive MIMO Radio Unit: 16T16R to 64T64R | +| Output Power | Total Radiated Power: Variable (Default 40W/10MHz) | +| Coverage <sup>(d)</sup> | Sectorized, Directional, Beamforming (Fixed/Dynamic) | +| Key Architecture Features | Split Architecture (O-RAN WG4 split option 7-2x), see<br>Figure 2.1.1-1: Base Station Architecture deploying lower level split without<br>protocol translation<br>Option for O-DU at Data Center or Cell Site; Integrated Architecture. See<br>Figure 2.1.1-3: Base Station with Integrated Architecture | + +Notes: + +(a) The options noted here are for the first stage, and do not preclude the study of other spectrum options, e.g., CBRS. Certain technology bands have specific regulatory requirements that must be followed + +(b) The system bandwidth is the total bandwidth typically assumed to derive the values for some KPIs such as area traffic capacity and user experienced data rate. + +(c) The options noted here are typical configurations. + +(d) Other options (e.g. Omni antennas) are not precluded. . + +(e) n78 CEPT makes reference to a European n78 sub-band (according with ECC Decision (11) 06 and CEPT + +### 2.2.6 Fronthaul Gateway + +A Fronthaul Gateway (FHGW) is deployed between an O-DU<sub>x</sub> and an O-RU<sub>y</sub> and provides the necessary protocol translation between splits x and y. Such a Fronthaul Gateway is being referred to as FHGW<sub>x→y</sub>. In Addition to the protocol translation capabilities, a Fronthaul Gateway can provide packet transport and aggregation capabilities. + +A Fronthaul Gateway can be deployed in any of the scenarios mentioned in the sections above. Generally, the attributes of a Fronthaul Gateway are given in Table 2.2.6-1. + +**Table 2.2.6-1: Attributes for Fronthaul Gateway** + +| Attributes | Values or Assumptions | +|------------------------------|------------------------------------------------------------------------------------------| +| Functionalities | Packet Switching, Radio Interface Translation | +| Protocol Translation Support | Translation between Split Option 8 and Split Option 7-2x (Refer to [6]) | +| Timing Capabilities | Compliant to S-Plane Protocol Specification in [6] | +| Deployment | Indoor and Outdoor | +| Interfaces | Interfaces to connect to O-DU <sub>x</sub><br>Interfaces to connect to O-RU <sub>y</sub> | + +# Chapter 3 Base Station Type Classification + +## 3.1 General + +The base stations for each usage scenario in chapter 2 apply to Wide Area Base Stations, Medium Range Base Stations and Local Area Base Stations. The definition for the three BS classes is given in subsection 4.4 of [2]. The BS classes for each deployment scenario described in this document are defined in Table 2.2.6-1 below. + +**Table 2.2.6-1: Base Station Classes for Deployment Scenarios** + +| Deployment Scenario | FR1/FR2 | Base Station Class | +|-------------------------------------------|---------|------------------------| +| Indoor Picocell Split Architecture | FR1 | Local Area/Medium Area | +| Indoor Picocell Integrated Architecture | FR1 | Local Area/Medium Area | +| Outdoor Picocell Integrated Architecture | FR1 | Medium Area | +| | FR2 | Medium Area | +| Outdoor Microcell Split Architecture | FR1 | Medium/Wide Area | +| | FR2 | Medium/Wide Area | +| Outdoor Microcell All-in-one Architecture | FR1 | Medium Area | +| Integrated Access and Backhaul | FR2 | Medium Area | +| Outdoor Macro | FR1 | Wide Area | + +## 3.2 Indoor + +For indoor coverage, the base station can be identified as Local Area Base Station, and there are two key architecture types, namely, the split architecture and the integrated architecture. + +NOTE: The hardware design may consider the co-location of MEC and UPF part in O-CU/O-DU functionality if needed. + +### 3.2.1 The split architecture + +Descriptions of the indoor split architecture are listed in Table 3.2.1-1. + +**Table 3.2.1-1: Descriptions of Attributes for the Indoor Picocell Split Architecture** + +| Attributes | Description | +|-----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Figure | Figure 2.1.1-1: Base Station Architecture deploying lower level split without protocol translation | +| Interface <sup>(a)</sup> | Open fronthaul interface | +| Functionality <sup>(b)</sup> | <p>Split Option 6:<br/>O-RU<sub>6</sub>: RF, IF, PHY (Downlink and uplink digital processing, baseband signal conversion to/from RF signal)<br/>O-CU & O-DU<sub>6</sub>: MAC, RLC, PDCP (Downlink and uplink baseband processing, supply system synchronization clock, signalling processing, OM function, interface with core network)</p> <p>Split Option 7-2x:<br/>O-RU: RF, IF, PHY-LOW (Downlink and uplink digital processing, baseband signal conversion to/from RF signal)<br/>O-CU & O-DU: PHY-HIGH, MAC, RLC, PDCP (Downlink and uplink baseband processing, supply system synchronization clock, signalling processing, OM function, interface with core network)</p> <p>Split Option 8:<br/>O-RU<sub>8</sub>: Downlink baseband signal convert to RF signal, uplink RF signal convert to baseband signal, interface with the fronthaul gateway<br/>O-CU & O-DU<sub>8</sub>: Downlink and uplink baseband processing, supply system synchronization clock, signalling processing, OM function, interface with core network and the fronthaul gateway<br/>Fronthaul gateway: Downlink broadcasting, uplink combining, power supply for O-RU<sub>8</sub>, cascade with other fronthaul gateway, synchronization clock</p> | +| Transmission media <sup>(b)</sup> | <p>From O-DU to Fronthaul gateway: Fiber;<br/>From Fronthaul gateway to O-RU: Fiber or Optical Electric Composite Cable</p> <p>From (O-DU&O-CU) to O-RU: Fiber or Optical Electric Composite Cable<br/>From (O-DU&O-CU) and core network:<br/>Fiber or Optical Electric Composite Cable; Trusted or Untrusted transport</p> | +| Duplex <sup>(b)</sup> | TDD, FDD | +| Deployment location | Indoor | +| Cell Coverage | Omni | +| MIMO Configuration <sup>(b)</sup> | SU-MIMO/MU-MIMO; up to 4TX/4RX | +| User distribution <sup>(c)</sup> | 20-200 | +| Fronthaul Latency | <p>Split Option 6: TBD<br/>Split Option 7-2x: fronthaul dependent (refer to [6])<br/>Split Option 8: 150us</p> | +| Synchronization <sup>(b)</sup> | GNSS, IEEE-1588v2, BDS | +| Power Supply Mode <sup>(b)</sup> | POE or by optical electric composite cables | + +Notes: + +- (a) The option noted here is for the first stage, and do not preclude other interface options. +- (b) The options noted here are for reference, and do not preclude other options. +- (c) The number of users distribution refers to the active users in one base station, and the options are for reference. + +### 3.2.2 The integrated architecture + +Descriptions of the integrated architecture are listed in Table 3.2.2-1. + +**Table 3.2.2-1: Descriptions of Attributes for the Indoor Picocell Integrated Architecture** + +| Attributes | Description | +|-----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Figure | Figure 2.1.1-3 | +| Interface <sup>(a)</sup> | F1 | +| Functionality <sup>(b)</sup> | O-DU+O-RU: Downlink and uplink baseband processing, supply system synchronization clock, signalling processing, OM function, interface with core network and, downlink baseband signal convert to RF signal, uplink RF signal convert to baseband signal | +| Transmission media <sup>(b)</sup> | Fiber or Optical Electric Composite Cable | +| Duplex <sup>(b)</sup> | TDD, FDD | +| Deployment location | Indoor | +| Cell Coverage | Omni | +| MIMO Configuration <sup>(b)</sup> | SU-MIMO/MU-MIMO; up to 4TX/4RX | +| User distribution <sup>(c)</sup> | 100 | +| Fronthaul Latency | Not Applicable | +| Synchronization <sup>(b)</sup> | GNSS, IEEE-1588v2, Sniffer, BDS | +| Power Supply Mode <sup>(b)</sup> | POE or by optical electric composite cables | + +Notes: + +- (a) The option noted here is for the first stage, and do not preclude other interface options. +- (b) The options noted here are for reference, and do not preclude other options. +- (c) The number of users distribution refers to the active users in one base station, and the options are for reference + +## 3.3 Outdoor + +For the outdoor scenario, the base station can be identified as a Medium Range Base Station, and there are three potential key architecture types, which are the split architecture, the integrated architecture and the all-in-one architecture. + +Note: The hardware design may consider the co-location of MEC and UPF part in O-CU/O-DU functionality if needed. + +### 3.3.1 Picocell + +The base station architecture for Picocell incorporates an integrated O-DU/O-RU architecture, and its description is listed in Table 3.3.1-1. + +**Table 3.3.1-1: Descriptions of Attributes for the Outdoor Picocell Architecture** + +| Attributes | Description | +|-----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Figure | Figure 2.1.1-3 | +| Interface <sup>(a)</sup> | F1 | +| Functionality <sup>(b)</sup> | O-DU+O-RU: Downlink and uplink baseband processing, supply system synchronization clock, signalling processing, OM function, interface with core network and, downlink baseband signal convert to RF signal, uplink RF signal convert to baseband signal | +| Transmission media <sup>(b)</sup> | Fiber or Optical Electric Composite Cable | +| Duplex <sup>(b)</sup> | TDD | +| Deployment location | Outdoor | +| Cell Coverage | Omni | +| MIMO Configuration <sup>(b)</sup> | SU-MIMO/MU-MIMO; up to 4TX/4RX | +| User distribution <sup>(c)</sup> | >200 | +| Fronthaul Latency | Not Applicable | +| Synchronization <sup>(b)</sup> | GNSS or IEEE-1588v2 | +| Power Supply Mode <sup>(b)</sup> | POE or by optical electric composite cables | + +Notes: + +- (a) The option noted here is for the first stage, and do not preclude other interface options. +(b) The options noted here are for reference, and do not preclude other options. +(c) The number of users distribution refers to the active users in one base station, and the options are for reference + +### 3.3.2 Microcell + +The base stations for FR1 microcell scenarios incorporate potential key architecture types, which are the split architecture and the all-in-one architecture. The base stations for FR2 Outdoor microcell scenarios incorporate a split RAN architecture. Their descriptions are listed in Table 3.3.2-1, Table 3.3.2-2, Table 3.3.2-3 and Table 3.3.2-4 + +**Table 3.3.2-1: Descriptions of Attributes for the FR1 Outdoor Microcell Architecture** + +| Attributes | Description | +|-----------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Figure | Figure 2.1.1-1: Base Station Architecture deploying lower level split without protocol translation<br>Figure 2.1.1-2 | +| Interface <sup>(a)</sup> | Open fronthaul interface (WG4) (Option 7-2x) | +| Functionality <sup>(b)</sup> | Provides lower layer split in RAN so that PHY-Hi, MAC/RLC/PDCP/SDAP/RRC could be centralized or virtualized and support CoMP features etc. | +| Transmission media <sup>(b)</sup> | Fiber, wireless to fiber | +| Duplex <sup>(b)</sup> | TDD | +| Deployment location | Outdoor | +| Cell Coverage | Omni; Sectorized | +| MIMO <sup>(b)</sup> | SU-MIMO/MU-MIMO; up to 16TX/16RX | +| User distribution <sup>(c)</sup> | >200 | +| Fronthaul Latency | Split Option 7-2x: fronthaul dependent (refer to [6]) | +| Synchronization <sup>(b)</sup> | GNSS or IEEE-1588v2 | +| Power Supply Mode <sup>(b)</sup> | DC/AC | + +Notes: + +- (a) The option noted here is for the first stage, and do not preclude other interface options. +(b) The options noted here are for reference, and do not preclude other options. +(c) The number of users distribution refers to the active users in one base station, and the options are for reference + +**Table 3.3.2-2: Descriptions of Attributes for the FR1 Enterprise Microcell Architecture** + +| Attributes | Description | +|-----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Figure | Figure 2.1.1-1: Base Station Architecture deploying lower level split without protocol translation | +| Interface <sup>(a)</sup> | Open fronthaul interface | +| Functionality <sup>(b)</sup> | <p>Split Option 7-2x:<br/> O-RU: RF, IF, PHY-LOW (Downlink and uplink digital processing, baseband signal conversion to/from RF signal)<br/> O-CU & O-DU: PHY-HIGH, MAC, RLC, PDCP (Downlink and uplink baseband processing, supply system synchronization clock, signalling processing, OM function, interface with core network)</p> <p>Split Option 8:<br/> O-RU: Downlink baseband signal convert to RF signal, uplink RF signal convert to baseband signal, interface with O-DU<br/> O-CU & O-DU: Downlink and uplink baseband processing, supply system synchronization clock, signalling processing, OM function, interface with core network and O-RU.</p> | +| Transmission media <sup>(b)</sup> | Fiber | +| Duplex <sup>(b)</sup> | TDD | +| Deployment location | Outdoor | +| Cell Coverage | Omni; Sectorized | +| MIMO <sup>(b)</sup> | SU-MIMO/MU-MIMO; up to 8TX/8RX | +| User distribution <sup>(c)</sup> | >300 | +| Fronthaul Latency | Split Option 7-2x: fronthaul dependent (refer to [6])<br>Split Option 8: 150us | +| Synchronization <sup>(b)</sup> | GNSS or IEEE-1588v2 | +| Power Supply Mode <sup>(b)</sup> | DC/AC | + +Notes: + +- (a) The option noted here is for the first stage, and do not preclude other interface options. +- (b) The options noted here are for reference, and do not preclude other options. +- (c) The number of users distribution refers to the active users in one base station, and the options are for reference + +**Table 3.3.2-3: Descriptions of Attributes for the FR1 Outdoor Microcell with All-In-One Architecture** + +| Attributes | Description | +|-----------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Figure | Figure 2.1.1-1: Base Station Architecture deploying lower level split without protocol translation | +| Interface | Not Applicable | +| Functionality <sup>(a)</sup> | O-CU+O-DU+O-RU: RF, IF, PHY-LOW (Downlink and uplink digital processing, baseband signal conversion to/from RF signal), PHY-HIGH, MAC, RLC, PDCP (Downlink and uplink baseband processing, supply system synchronization clock, signalling processing, OM function, interface with core network) | +| Transmission media <sup>(a)</sup> | Fiber, wireless to fiber | +| Duplex <sup>(a)</sup> | TDD | +| Deployment location | Outdoor | +| Cell Coverage | Omni; Sectorized | +| MIMO <sup>(a)</sup> | SU-MIMO/MU-MIMO; up to 2TX/2RX | +| User distribution <sup>(b)</sup> | >300 | +| Fronthaul Latency | Not Applicable | +| Synchronization <sup>(a)</sup> | GNSS or IEEE-1588v2 | +| Power Supply Mode <sup>(a)</sup> | DC/AC | + +Notes: + +**(a)** The option noted here is for reference, and do not preclude other options. + +**(b)** The number of users distribution refers to the active users in one base station, and the options are for reference. + +**Table 3.3.2-4: Descriptions of Attributes for the FR2 Outdoor Microcell Architecture** + +| Attributes | Description | +|-----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Figure | Figure 2.1.1-1: Base Station Architecture deploying lower level split without protocol translation | +| Interface <sup>(a)</sup> | F1 interface between O-CU/O-DU (Split Option 2)<br>Open fronthaul interface (WG4) between O-DU/O-RU (Option 7-2x) | +| Functionality <sup>(b)</sup> | O-DU/O-RU: Downlink and uplink baseband processing, supply system synchronization clock, scheduling, signalling processing, OM function, interface with core network and, Downlink baseband signal convert to RF signal, uplink RF signal convert to baseband signal | +| Transmission media <sup>(b)</sup> | Fiber, wireless to fiber | +| Duplex <sup>(b)</sup> | TDD | +| Deployment location | Small cell, Outdoor, Urban/Suburban | +| Cell Coverage | Sectorized | +| MIMO Configuration <sup>(b)</sup> | SU-MIMO/MU-MIMO; up to 4TX/4RX | +| User distribution <sup>(c)</sup> | >100 | +| Fronthaul Latency | Split Option 7-2x: fronthaul dependent (refer to [6]) | +| Synchronization <sup>(b)</sup> | GNSS or IEEE-1588v2 | +| Power Supply Mode <sup>(b)</sup> | AC or POE or by optical electric composite cables | + +Notes: + +**(a)** The option noted here is for the first stage, and do not preclude other interface options. + +**(b)** The options noted here are for reference, and do not preclude other options. + +**(c)** The number of users distribution refers to the active users in one base station, and the options are for reference + +### 3.3.3 Integrated access and backhaul (IAB) + +The IAB base station uses an integrated architecture, and its attributes are listed in Table 3.3.3-1. + +**Table 3.3.3-1: Descriptions of Attributes for the IAB Architecture** + +| Attributes | Description | +|-----------------------------------|-------------------------------------------------------------------------------------------| +| Reference Figure | Figure 2.2.4-1 | +| Interface <sup>(a)</sup> | F1 Interface (WG5) (split option 2)<br>Open fronthaul interface (WG4) (split option 7-2x) | +| Functionality <sup>(b)</sup> | Provides support for multi-hop relay per Rel. 16. | +| Transmission media <sup>(b)</sup> | Fiber, wireless to fiber | +| Duplex <sup>(b)</sup> | TDD | +| Deployment location | Outdoor mobile/fixed relays, Urban/Suburban | +| Cell Coverage | Omni or Sectorized | +| MIMO Configuration <sup>(b)</sup> | SU/MIMO and MU/MIMO; up to 4TX/4RX | +| User distribution <sup>(c)</sup> | 30 - 40 | +| Latency | 4ms/hop for eMBB | +| Synchronization <sup>(b)</sup> | GNSS, or OTA per Rel-16 | +| Power Supply Mode <sup>(b)</sup> | AC, POE, or by optical electric composite cables | + +Notes: + +- (a) The option noted here is for the first stage, and do not preclude other interface options. +- (b) The options noted here are for reference, and do not preclude other options. +- (c) The number of users distribution refers to the active users in one base station, and the options are for reference + +### 3.3.4 Macrocell + +The base stations for macrocell scenarios incorporate a split RAN architecture. Their descriptions are listed in Table 3.3.4-1. + +**Table 3.3.4-1: Descriptions of Attributes for the FR1 Outdoor Macrocell Architecture** + +| Attributes | Description | +|-----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Figure | Figure 2.1.1-1 | +| Interface <sup>(a)</sup> | Split Architecture (O-RAN WG4 split option 7-2x). | +| Functionality <sup>(b)</sup> | Split Option 7-2x:<br>O-RU: RF, IF, PHY-LOW (Downlink and uplink digital processing, baseband signal conversion to/from RF signal)<br>O-DU: PHY-HIGH, MAC, RLC, PDCP (Downlink and uplink baseband processing, supply system synchronization clock, signalling processing)<br>O-CU: PDCP, SDAP, RRC (Control and User Plane separation, RRM function, interface with core network) | +| Transmission media <sup>(b)</sup> | Fiber, wireless to fiber | +| Duplex <sup>(b)</sup> | FDD, TDD | +| Deployment location | Outdoor | +| Cell Coverage | Sectorized, directional | +| MIMO <sup>(b)</sup> | Up to 16 layer MIMO; up to 64TX/64RX | +| User distribution <sup>(c)</sup> | >200 | +| Fronthaul Latency | 160-200 $\mu$ sec | +| Synchronization <sup>(b)</sup> | GNSS, IEEE-1588v2, SyncE | +| Power Supply Mode <sup>(b)</sup> | DC/AC | + +Notes: + +- (a) The option noted here is for the first stage, and do not preclude other interface options. +- (b) The options noted here are for reference, and do not preclude other options. +- (c) The number of Users distribution refers to the active users in one base station, and the options are for reference + +# Chapter 4 Key performance indicators + +## 4.1 Peak data rate + +Peak data rate is the highest theoretical data rate which is the received data bits assuming error-free conditions assignable to a single mobile station, when all assignable radio resources for the corresponding link direction are utilized (i.e., excluding radio resources that are used for physical layer synchronization, reference signals or pilots, guard bands and guard times). + +| Indoor | Outdoor | | | | +|-----------------------------------------------------|---------------------------------------------------------------------|---------------------------------------------------------------------|-----------------------------------------------------------------------------------------------|---------------------------------| +| Pico | Pico | Micro | IAB | Macro | +| 0.75-1.33Gbps (DL);<br>0.25-0.67Gbps (UL);<br>NOTE1 | FR1: up to 6/12 Gbps<br>(UL/DL)<br>FR2: up to 15/30 Gbps<br>(UL/DL) | FR1: up to 6/12 Gbps<br>(UL/DL)<br>FR2: up to 15/30 Gbps<br>(UL/DL) | FR2:<br>3-12 Gbps (DL);<br>1.5-6 Gbps (UL)<br>For n260:<br>12-24 Gbps (DL);<br>6-12 Gbps (UL) | FR1: up to 6/12<br>Gbps (UL/DL) | + +NOTE1: This requirement is calculated based on the frame structure UL:DL=1:1 (TDD). + +## 4.2 Peak spectral efficiency + +Peak spectral efficiency is the highest theoretical data rate (normalized by bandwidth), which is the received data bits assuming error-free conditions assignable to a single mobile station, when all assignable radio resources for the corresponding link direction are utilized (i.e., excluding radio resources that are used for physical layer synchronization, reference signals or pilots, guard bands and guard times). + +Higher frequency bands could have higher bandwidth, but lower spectral efficiency and lower frequency bands could have lower bandwidth but higher spectral efficiency. Thus, peak data rate cannot be directly derived from peak spectral efficiency and bandwidth multiplication. + +Peak spectral efficiency (bps/Hz) = Peak data rate (bps)/ bandwidth (Hz). + +| Indoor | Outdoor | | | | +|--------------------------------------------------------|-------------------------------------------|-------------------------------------------|-------------------------------------------|----------------------------------| +| Pico | Pico | Micro | IAB | Macro | +| 7.5-13.3 bps/Hz (DL);<br>2.5-6.7 bps/Hz (UP);<br>NOTE1 | 30 bps/Hz (DL)<br>15 bps/Hz (UL)<br>NOTE1 | 30 bps/Hz (DL)<br>15 bps/Hz (UL)<br>NOTE1 | 30 bps/Hz (DL)<br>15 bps/Hz (UL)<br>NOTE1 | 30 bps/Hz (DL)<br>15 bps/Hz (UL) | + +NOTE1: This requirement is calculated based on the frame structure UL:DL=1:1 (TDD). + +## 4.3 Bandwidth + +Bandwidth means the maximal aggregated total system bandwidth. It may be supported by single or multiple RF carriers. It is a quantitative KPI. + +| Indoor | Outdoor | | | | +|---------|------------------------------------------|------------------------------------------|--------------------------------------------------|--------------------| +| Pico | Pico | Micro | IAB | Macro | +| 100 MHz | FR1: up to 200 MHz<br>FR2: up to 800 MHz | FR1: up to 200 MHz<br>FR2: up to 1.2 GHz | FR2: 100 – 400 MHz<br>For n260: 400 – 800<br>MHz | FR1: up to 200 MHz | + +## 4.4 Control plane latency + +Control plane latency refers to the time for UE to move from a battery efficient state (e.g., IDLE) to start of continuous data transfer (e.g., ACTIVE). + +| Indoor | Outdoor | | | | +|--------|---------|-------|----------|-------| +| Pico | Pico | Micro | IAB | Macro | +| 10ms | 10ms | 10ms | 10ms/hop | 10ms | + +## 4.5 User plane latency + +The time it takes to successfully deliver an application layer packet/message from the radio protocol layer 2/3 SDU ingress point to the radio protocol layer 2/3 SDU egress point via the radio interface in both uplink and downlink directions, where neither device nor base station reception is restricted by DRX. + +| Indoor | Outdoor | | | | +|---------------------------|---------------------------|---------------------------|-------------------------------|--------------------------| +| Pico | Pico | Micro | IAB | Macro | +| URLLC UL/DL(ms):<br>0.5ms | URLLC UL/DL(ms):<br>0.5ms | URLLC UL/DL(ms):<br>0.5ms | URLLC UL/DL(ms):<br>0.5ms/hop | URLLC UL/DL (ms):<br>1ms | +| eMBB: UL/DL(ms):<br>4ms | eMBB: UL/DL(ms):<br>4ms | eMBB: UL/DL(ms):<br>4ms | eMBB: UL/DL(ms):<br>4ms/hop | eMBB: UL/DL (ms):<br>4ms | + +## 4.6 Mobility + +Mobility means the maximum user speed at which a defined QoS can be achieved (in km/h). + +| Indoor | Outdoor | | | | +|--------|---------|-----------------------------|----------|------------------------------------------| +| Pico | Pico | Micro | IAB | Macro | +| 3km/h | <60km/h | <500km/h (high speed train) | 120 km/h | 120 km/h<br>(excluding high speed train) | + +1 + +2 \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/03372371b2317aeec4e35c57e1b1aa08_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/03372371b2317aeec4e35c57e1b1aa08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0eaff8daf899ebd83f30c1f3f8ee34faf090931a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/03372371b2317aeec4e35c57e1b1aa08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b20cd863f7b28cc940dc064b9d95579f8492daef7facddd93a913cb60e906c8d +size 34507 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/07fb24eff70572df4ec20114b90a904a_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/07fb24eff70572df4ec20114b90a904a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..be9c41c0e1ab90b33109474a0ac58eb8acf3f1d3 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/07fb24eff70572df4ec20114b90a904a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:45d0b6536b46bb9c7c194a63c8d4736cdb9e7b3d11c2e4f02e3a071add18981a +size 78196 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/0f541c8bdd1d232dba5bd2d572692db3_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/0f541c8bdd1d232dba5bd2d572692db3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..167128cb03c1d2af1fcda40213e29d4a69cfdb2b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/0f541c8bdd1d232dba5bd2d572692db3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7eb70d374ad3094692aeee1a466e670602ff427dc23ebcbc5820746342aee4ec +size 35363 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/13c759b5b009b236d5f6322847b87f21_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/13c759b5b009b236d5f6322847b87f21_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4a0cf2d2385351641aebba1fd81904f6a5171225 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/13c759b5b009b236d5f6322847b87f21_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:49809205a5ec543eb57d1a6c98b6929f49cd6921eb3afa5027b113384a66ef26 +size 27112 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/18ef10945e75bbfc200646c46ca71e7c_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/18ef10945e75bbfc200646c46ca71e7c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..049f5d82162629329157710f87661bfef65819ae --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/18ef10945e75bbfc200646c46ca71e7c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:26ac6165545d1f8938595d4a54925e81908ddcd49c04280effba916afed745e1 +size 31979 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/2d269f0c746da6be44e39f4da6abbbb6_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/2d269f0c746da6be44e39f4da6abbbb6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6787f2f36f06e5a628221c6d5dc32bce07056971 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/2d269f0c746da6be44e39f4da6abbbb6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9f0c486d3173ea990a19d3a554149cbd476039b981249d9ee32672b8b7993066 +size 38823 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/342d1ccd941f7abe0e8c59ae90b8c128_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/342d1ccd941f7abe0e8c59ae90b8c128_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ed8575ff1fda75fb53bccf15351a90692d538a8c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/342d1ccd941f7abe0e8c59ae90b8c128_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:65560fdfef413779b4c4bbed72ec5f52fa3469dcfb925c016777575fdddbf219 +size 28466 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/4f745312c4e8def1925335e4ff9afea9_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/4f745312c4e8def1925335e4ff9afea9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ab0b66c875a8dddbfc3497b7e279a75b1f8a5447 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/4f745312c4e8def1925335e4ff9afea9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:231c03ef6de33110f69fecf4b370f9af62a788b48032e27f7f2e52142c372629 +size 35211 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..debceee0b47444ead4235bfb842ae0e0f55e9bf1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/543a649b0d046b82b0c523bd101f1d6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c5ef872d704eef2a7102f968c144e3b22a959003dd192ef5acd1c286aa4815e +size 4561 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/619e3c03012f1d224bd8717769f3a0ec_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/619e3c03012f1d224bd8717769f3a0ec_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f3d68fb00ba4ba9902cc56438734dbcbae80339 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/619e3c03012f1d224bd8717769f3a0ec_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b3725fd8d1dd4daa76b5e3931c069c91beb11a22f4767b3dddef8ecd496d910f +size 56987 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/751ad993940b40a389624f43f9f94d36_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/751ad993940b40a389624f43f9f94d36_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b63ac5c5ca4c4336301308c9693cc3219eb4a591 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/751ad993940b40a389624f43f9f94d36_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:18a7de5478f692ace9216f1dd6c2dc84cb08a06683149d73aff8cc60c4f6f2a6 +size 4509 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/8aee1e2c6cd9828215a4b12958168c56_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/8aee1e2c6cd9828215a4b12958168c56_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a414d64a9349f8624a083eb236f0155798187c27 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/8aee1e2c6cd9828215a4b12958168c56_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:61fae17c4a2c683a3357c962bfa12d86bcc26ff8b863b732a90c418b415fd445 +size 35550 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/932a391ae44425db645e8305c3e18868_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/932a391ae44425db645e8305c3e18868_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..668e4f36acb3638372bb15e8beb68ae14cd23866 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/932a391ae44425db645e8305c3e18868_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9617b3e0964b1f329c03018b76b0234e1f9d91fdd2f064aad5feebf43f3320ca +size 21248 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/94bc0bb472bf4f6dbdc3f37f3d4fd0a2_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/94bc0bb472bf4f6dbdc3f37f3d4fd0a2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3b2dde346152a1893815f7daef1bc5a6b09a2a23 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/94bc0bb472bf4f6dbdc3f37f3d4fd0a2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2ca9b2be65c8d3116a2604c6df4bb9d142e26924ec9f661e69da8d7b83776c7d +size 15655 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..08a9c509da7e591b85ce9c11c7659f729776badc --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e51e29a8c647908fe9f48f56b660f7378772dafa9202a271bcb2032f560fafe1 +size 4531 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/a075681cfa5575e1f27913b2037accd2_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/a075681cfa5575e1f27913b2037accd2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1f2d90bbbc80f0fa7878ff856f9b85834c312429 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/a075681cfa5575e1f27913b2037accd2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cb602853e891745a9510d499253cea8018d0e4d7840cf40a09e252dcd4933e79 +size 15329 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/a81b5b876149f0126687fce63344420e_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/a81b5b876149f0126687fce63344420e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cc3cc9d9cadc171d84d08da336b9b939458caa27 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/a81b5b876149f0126687fce63344420e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:de46f734f1c70c96345c1adf1658be5906db3b312f31520d39ac96a0468c9285 +size 141699 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/b22d295ebd15e76bb9fb6469c44b7ffa_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/b22d295ebd15e76bb9fb6469c44b7ffa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6bc99cb6f7e5d2374e2b1a16852c0713d46410e4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/b22d295ebd15e76bb9fb6469c44b7ffa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3617d235cd831327524043f8ee1a89b2b56cddfc2ba7dcc565a7b04e8c6ea97f +size 41321 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/b33888f97874a82cfb4743e3fb7ff477_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/b33888f97874a82cfb4743e3fb7ff477_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e99e7b2fc53556402f3229b1bd0e73d693cfd4c0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/b33888f97874a82cfb4743e3fb7ff477_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b6bc8db0d9350126278525eaa442adb70f85003aacb06081e6642530d43562e +size 68672 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/c11f2148aa10accdfd2f411b5dc51091_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/c11f2148aa10accdfd2f411b5dc51091_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8aa7ccfb02b381be69f887d762bf437fffbbb858 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/c11f2148aa10accdfd2f411b5dc51091_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4408f64911972afb26318cec0d6562b9f06d2d57ffac480f33323e0566b0841f +size 39492 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/c1c72413b3adade28073deb355cd224b_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/c1c72413b3adade28073deb355cd224b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7a09f0552389e970b4056a8c2f1ccf273f3e79d7 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/c1c72413b3adade28073deb355cd224b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c25cc3c0979cb5d1b66fc10dcbf63eceaad3aaf3a90fd18d3c9b7e60cb7571e5 +size 33523 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/cc74300c08a973cf447e7a07f4db03f3_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/cc74300c08a973cf447e7a07f4db03f3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aafeb1ead4289cb09d9efda243dce18be99dc19e --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/cc74300c08a973cf447e7a07f4db03f3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:950df6a6b1c507bcb922999455db340efcaee916fb1dbbbae205af7c2b339ce2 +size 43309 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/e2cf0dcf37316b72723f66983494a2ae_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/e2cf0dcf37316b72723f66983494a2ae_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cd5b06948ae8601667481c9900a32405319e3a97 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/e2cf0dcf37316b72723f66983494a2ae_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bdb53f79a41ed3f7fde365acf7098493dbe029345557afd58f1c22a24e6f9188 +size 47530 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/f11c22832f1b704bc78d6534ae671707_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/f11c22832f1b704bc78d6534ae671707_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..177351ab5ef5b4ac9c28fee6595310aa3c7c929b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/f11c22832f1b704bc78d6534ae671707_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:018b00f084ea7ed43fdf85c27fd850157cebe839c4f8c5fa879c60df49e9c2a5 +size 4512 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/raw.md b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..c7292e74c9812441801c55de9a358567a46c9b81 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00/raw.md @@ -0,0 +1,1450 @@ + + +# --- **O-RAN Work Group 7 White-box Hardware Hardware Architecture, Requirements and Reference Design Specification for Enterprise Microcell** + +Copyright © 2023 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# Contents + +| | | +|----------------------------------------------------------------------|----| +| List of figures ..... | 4 | +| List of tables ..... | 4 | +| Foreword..... | 6 | +| Modal verbs terminology ..... | 6 | +| 1 Scope..... | 7 | +| 2 References..... | 7 | +| 2.1 Normative references..... | 7 | +| 2.2 Informative references ..... | 7 | +| 3 Definition of terms, symbols and abbreviations..... | 8 | +| 3.1 Terms ..... | 8 | +| 3.2 Symbols ..... | 8 | +| 3.3 Abbreviations..... | 8 | +| 4 Deployment Scenarios and White Box Base Station Architecture ..... | 11 | +| 4.1 Deployment Scenarios ..... | 11 | +| 4.2 White Box Base Station Architecture ..... | 12 | +| 5 Hardware Architecture ..... | 12 | +| 5.1 O-CU Hardware Architecture ..... | 12 | +| 5.1.1 O-CU Architecture Diagram ..... | 13 | +| 5.1.2 O-CU Functional Module Description ..... | 13 | +| 5.1.3 O-CU Interfaces ..... | 13 | +| 5.2 O-DU <sub>7-2x</sub> Hardware Architecture ..... | 13 | +| 5.2.1 O-DU <sub>7-2x</sub> Architecture Diagram ..... | 13 | +| 5.2.2 O-DU <sub>7-2x</sub> Functional Module Description ..... | 14 | +| 5.2.3 O-DU <sub>7-2x</sub> Interfaces ..... | 15 | +| 5.3 O-RU <sub>7-2x</sub> Hardware Architecture ..... | 15 | +| 5.3.1 O-RU <sub>7-2x</sub> Architecture Diagram ..... | 16 | +| 5.3.2 O-RU <sub>7-2x</sub> Functional Module Description ..... | 16 | +| 6 Hardware Requirements..... | 17 | +| 6.1 O-CU Requirements ..... | 17 | +| 6.2 O-DU <sub>x</sub> Common Requirements ..... | 17 | +| 6.2.1 Performance ..... | 17 | +| 6.2.2 Interfaces ..... | 18 | +| 6.2.3 Environmental and EMC..... | 18 | +| 6.2.4 Mechanical, Thermal and Power..... | 18 | +| 6.3 O-DU <sub>x</sub> Split Option Specific Requirements ..... | 19 | +| 6.4 O-RU <sub>x</sub> Requirements ..... | 19 | +| 6.4.1 Performance ..... | 20 | +| 6.4.2 Interfaces ..... | 21 | +| 6.4.3 Environmental and EMC..... | 21 | +| 6.4.4 Mechanical, Thermal and Power..... | 21 | +| 6.5 O-RU <sub>x</sub> Split Option Specific Requirements ..... | 22 | +| 7 Hardware Reference Design..... | 22 | +| 7.1 O-CU Hardware Reference Design ..... | 22 | +| 7.2 O-DU <sub>7-2x</sub> Hardware Reference Design 1..... | 23 | +| 7.2.1 O-DU <sub>7-2x</sub> High-Level Functional Block Diagram ..... | 23 | +| 7.2.2 O-DU <sub>7-2x</sub> Hardware Components ..... | 24 | +| 7.2.3 Synchronization and Timing ..... | 26 | +| 7.2.4 External Interface Ports..... | 26 | +| 7.2.5 O-DU <sub>7-2x</sub> Firmware..... | 27 | +| 7.2.6 Mechanical ..... | 27 | + +| | | | +|---------------|----------------------------------------------------------------|----| +| 7.2.7 | Power Unit ..... | 28 | +| 7.2.8 | Thermal ..... | 29 | +| 7.2.9 | Environmental and Regulations ..... | 29 | +| 7.3 | O-DU <sub>7-2x</sub> Hardware Reference Design 2..... | 29 | +| 7.3.1 | O-DU <sub>7-2x</sub> High-Level Functional Block Diagram ..... | 29 | +| 7.3.2 | O-DU <sub>7-2x</sub> Hardware Components ..... | 30 | +| 7.3.3 | Synchronization and Timing ..... | 31 | +| 7.3.4 | External Interface Ports ..... | 31 | +| 7.3.5 | O-DU <sub>7-2x</sub> Firmware..... | 31 | +| 7.3.6 | Mechanical ..... | 31 | +| 7.3.7 | Power Unit ..... | 33 | +| 7.3.8 | Thermal ..... | 33 | +| 7.3.9 | Environmental and Regulations ..... | 33 | +| 7.4 | O-RU <sub>7-2x</sub> Hardware Reference Design ..... | 34 | +| 7.4.1 | O-RU <sub>7-2x</sub> High-Level Functional Block Diagram..... | 34 | +| 7.4.2 | O-RU <sub>7-2x</sub> Hardware Components ..... | 34 | +| 7.4.3 | Synchronization and Timing ..... | 41 | +| 7.4.4 | External Interface Ports ..... | 44 | +| 7.4.5 | Mechanical ..... | 44 | +| 7.4.6 | Power Unit ..... | 45 | +| 7.4.7 | Thermal ..... | 46 | +| 7.4.8 | Environmental and Regulations ..... | 46 | +| History ..... | | 47 | + +# List of figures + +| | | +|-----------------------------------------------------------------------------------------|----| +| Figure 4.2-1: Split Architecture ..... | 12 | +| Figure 5.1-1: O-CU White Box Hardware Block Diagram ..... | 13 | +| Figure 5.2-1: O-DU <sub>7-2x</sub> with Split Physical Layer Function ..... | 14 | +| Figure 5.2-2: O-DU <sub>7-2x</sub> Functional Block and Interface Diagram. .... | 15 | +| Figure 5.3-1 O-RU <sub>7-2x</sub> Architecture Diagram ..... | 16 | +| Figure 5.3-2: O-RU <sub>7-2x</sub> Functional Module Diagram ..... | 17 | +| Figure 7.2-1 O-DU <sub>7-2x</sub> Functional Block Diagram..... | 23 | +| Figure 7.2-2 Single-chip FPGA-based Hardware Acceleration in O-DU <sub>7-2x</sub> ..... | 26 | +| Figure 7.2-3 HW Accelerator Timing and Synchronization ..... | 26 | +| Figure 7.2-4 Mother Board Layout Diagram ..... | 28 | +| Figure 7.3-1 O-DU <sub>7-2x</sub> Hardware Block Diagram..... | 30 | +| Figure 7.3-2: Mother Board Layout Diagram ..... | 32 | +| Figure 7.3-3: Chassis Mechanical Diagram ..... | 33 | +| Figure 7.4-1 O-RU <sub>7-2x</sub> High-Level Functional Block Diagram ..... | 34 | +| Figure 7.4-2 Digital Processing Unit Block Diagram ..... | 35 | +| Figure 7.4-3 Power Amplifier Reference Design ..... | 39 | +| Figure 7.4-4 LNA Reference Design..... | 40 | +| Figure 7.4-5 Circulator Reference Design..... | 41 | +| Figure 7.4-6: PLL Reference Design Diagram ..... | 43 | +| Figure 7.4-7 Mechanical Enclosure Diagram ..... | 44 | +| Figure 7.4-8 Power Unit Design ..... | 46 | + +# List of tables + +| | | +|-----------------------------------------------------------------------------------|----| +| Table 6.2-1: O-DU <sub>7-2x</sub> Performance Requirements..... | 17 | +| Table 6.2-2: O-DU <sub>7-2x</sub> Interface Requirements ..... | 18 | +| Table 6.2-3: O-DU <sub>7-2x</sub> EMC Requirements ..... | 18 | +| Table 6.2-4: O-DU <sub>7-2x</sub> Mechanical Requirements ..... | 19 | +| Table 6.2-5: O-DU <sub>7-2x</sub> Thermal Requirements ..... | 19 | +| Table 6.2-6: O-DU <sub>7-2x</sub> Power Requirements ..... | 19 | +| Table 6.4-1: O-RU <sub>7-2x</sub> Performance Requirements ..... | 20 | +| Table 6.4-2: O-RU <sub>7-2x</sub> Interface Requirements ..... | 21 | +| Table 6.4-3: O-RU <sub>7-2x</sub> Environmental and EMC Requirements ..... | 21 | +| Table 6.4-4: O-RU <sub>7-2x</sub> Mechanical, Thermal and Power Requirements..... | 22 | +| Table 7.2-1 Processor Feature List ..... | 24 | +| Table 7.2-2 Memory Channel Feature List ..... | 24 | +| Table 7.2-3 Accelerator Hardware Features ..... | 25 | +| Table 7.2-4 Hardware Accelerator Firmware Features ..... | 25 | +| Table 7.2-5 External Port List ..... | 27 | +| Table 7.2-6 O-DU <sub>7-2x</sub> Power Requirements ..... | 29 | +| Table 7.2-7 Environmental Features ..... | 29 | +| Table 7.3-1: The Processor Feature List ..... | 30 | +| Table 7.3-2: The Memory Channel Feature List ..... | 30 | +| Table 7.3-3: External Port List ..... | 31 | +| Table 7.3-4: Power supply unit feature list ..... | 33 | + +| | | +|--------------------------------------------------------------|----| +| Table 7.3-5: Environmental Features ..... | 33 | +| Table 7.4-1 FPGA Resource Requirements..... | 35 | +| Table 7.4-2 RF Requirements ..... | 35 | +| Table 7.4-3 Power Amplifier Interface Requirements..... | 38 | +| Table 7.4-4 Power Amplifier RF Requirements ..... | 38 | +| Table 7.4-5 LNA Interfaces Requirements..... | 39 | +| Table 7.4-6 LNA RF Requirements..... | 40 | +| Table 7.4-7 Circulator RF Requirements..... | 41 | +| Table 7.4-8: Interface requirements of the clocking..... | 41 | +| Table 7.4-9: Clocking RF requirements ..... | 42 | +| Table 7.4-10 External Port List ..... | 44 | +| Table 7.4-11 Digital Processing Unit Power Requirements..... | 45 | +| Table 7.4-12 RF Processing Unit Power Requirements ..... | 45 | +| Table 7.4-13 Environmental Features ..... | 46 | + +# --- Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document specifies system requirements, high-level architecture and hardware reference design for the Enterprise Microcell deployment scenario as specified in the Deployment Scenarios and Base Station Classes document[1]. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN.WG7.DSC.0-v04.00, "O-RAN Deployment Scenarios and Base Station Classes 4.0". +- [2] 3GPP TR 21.905, "Vocabulary for 3GPP Specifications". +- [3] 3GPP TS 38.104, "NR; Base Station (BS) radio transmission and reception". +- [4] O-RAN.WG4.CUS.0-v10.00, "O-RAN Control, User and Synchronization Plane Specification 10.0". +- [5] O-RAN.WG4.MP.0-v10.00, "O-RAN Management Plane Specification 10.0". +- [6] 3GPP TS 38.113, "NR: Base Station (BS) Electromagnetic Compatibility (EMC)". +- [7] O-RAN.WG1.O-RAN-Architecture-Description-v07.00, "O-RAN Architecture Description 7.0". + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long term validity. + +The following referenced documents are not necessary for the application of the present document but they assist + +the user with regard to a particular subject area. + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in [2] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in [2]. + +**Carrier Frequency:** Center frequency of the cell. + +**F1 interface:** The open interface between O-CU and O-DU defined by 3GPP TS 38.473. + +**Frequency Band:** A designated frequency range for the operation of the base station and the UE radios. 5G NR frequency bands are divided into two different frequency ranges: Frequency Range 1 (FR1) that mainly includes sub-6GHz frequency bands, some of which are bands traditionally used by previous standards but has been extended to cover potential new spectrum offerings from 410MHz to 7125MHz; Frequency Range 2 (FR2) that includes frequency bands from 24.25 GHz to 52.6 GHz. Bands in this millimeter wave range have shorter range but higher available bandwidth than bands in the FR1. + +**Frequency Range:** It refers to bandwidth defined by the frequency range within which the Base Station can be operated, defined by the band-pass filter of the BS; e.g., 3.4 – 3.8 GHz (400 MHz) + +**Occupied Bandwidth (OBW):** It refers to the bandwidth occupied by the base station when operated, defined by the sum of the active bandwidths of the band allocation(s) operated. As defined by 3GPP TS 34.121 section 5.8, occupied bandwidth is the bandwidth containing 99% of the total integrated power of the transmitted spectrum, centered on the assigned channel frequency. The bandwidth between the 0.5% power frequency points is the occupied bandwidth. + +**Instantaneous Bandwidth (IBW):** It refers to the bandwidth in which all frequency components can be simultaneously analyzed. It is defined by the frequency boundaries of the operating band(s). + +**Fronthaul Gateway (FHGW):** A fronthaul gateway is a physical entity that is located between a distributed unit and one or more radio units where it distributes, aggregates, and/or converts fronthaul protocols between the distributed unit and multiple radio units. + +**gNB:** A RAN node providing NR user plane and control plane protocol terminations towards the UE, and connected via the NG interface to the 5GC + +**Integrated architecture:** In the integrated architecture, the O-RU and O-DU are implemented on one platform. Each O-RU and RF front end is associated with one O-DU. They are then aggregated to O-CU and connected by F1 interface. + +**Split architecture:** The O-RU and O-DU are physically separated from one another in this architecture. A switch may aggregate multiple O-RUs to one O-DU. O-DU, switch and O-RUs are connected by the fronthaul interface as defined in WG4. + +## 3.2 Symbols + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in [2] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, as in [2]. + +| | | +|------|-----------------------------------------------------------------------------------| +| 7-2x | Fronthaul interface split option as defined by O-RAN WG4, also referred to as 7-2 | +| 3GPP | Third Generation Partnership Project | + +| | | +|-------|-------------------------------------------------------| +| 5G | Fifth-Generation [Mobile Communications] | +| 5GC | 5G Core | +| ACS | Adjacent Channel Selectivity | +| ADC | Analog to Digital Converter | +| AFE | Analog Front End | +| AFU | Antenna Filter Unit | +| ASIC | Application Specific Integrated Circuit | +| BH | Backhaul | +| BMC | Baseboard Management Controller | +| BPSK | Binary Phase Shift Keying | +| BS | Base Station | +| CFR | Crest Factor Reduction | +| CISPR | International Special Committee on Radio Interference | +| CLK | Clock | +| CPU | Central Processing Unit | +| CRC | Cyclic Redundancy Check | +| CU | Central Unit | +| DAC | Digital to Analog Converter | +| DDC | Digital Down Conversion | +| DDR | Double Data Rate | +| DFE | Digital Front End | +| DIMM | Dual-Inline-Memory-Modules | +| DL | Downlink | +| DPD | Digital Pre-Distortion | +| DSP | Digital Signal Processor | +| DU | Distributed Unit | +| DUC | Digital Up Conversion | +| eCPRI | Enhanced Common Public Radio Interface | +| ECC | Error Correcting Code | +| EMC | ElectroMagnetic Compatibility | +| EVM | Error Vector Magnitude | +| FCC | Federal Communications Commission | +| FEC | Forward Error Correction | +| FFT | Fast Fourier Transform | +| FH | Fronthaul | +| FHGW | Fronthaul Gateway | +| FPGA | Field Programmable Gate Array | + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| GbE | Gigabit Ethernet | +| GNSS | Global Navigation Satellite System | +| GPP | General Purpose Processor | +| GPS | Global Positioning System | +| IEEE | Institute of Electrical and Electronics Engineers | +| IFFT | Inverse Fast Fourier Transform | +| IMD | InterModulation Distortion | +| IP | Internet Protocol | +| I/O | Input/Output | +| JTAG | Joint Test Action Group | +| L1 | Layer 1, also referred to as PHY or Physical Layer | +| L2 | Layer 2, also referred to as Data Link layer in OSI model | +| L3 | Layer 3, also referred to as Network layer in OSI model | +| LDPC | Low-Density Parity Codes | +| LDO | Low dropout | +| LLS | Lower Layer Split | +| LRDIMM | Load-Reduced Dual In-line Memory Module | +| LNA | Low Noise Amplifier | +| LTE | Long Term Evolution | +| LVDS | Low-Voltage Differential Signaling | +| MAC | Media Access Control | +| MIMO | Multiple Input Multiple Output | +| MCP | Multi-Chip Package | +| NG | Next Generation | +| NR | New Radio | +| OAM | Operations, Administrations and Maintenance | +| O-CU | O-RAN Centralized Unit as defined by O-RAN | +| O-DU | O-RAN Distributed Unit as defined by O-RAN | +| O-DU <sub>x</sub> | A specific O-RAN Distributed Unit having fronthaul split option x where x may be 6, 7-2x (as defined by WG4) or 8 | +| O-RU | O-RAN Radio Unit as defined by O-RAN | +| O-RU <sub>x</sub> | A specific O-RAN Radio Unit having fronthaul split option x, where x is 6, 7-2x (as defined by WG4) or 8, and which is used in a configuration where the fronthaul interface is the same at the O-DU <sub>x</sub> | +| OCXO | Oven Controlled Crystal Oscillator | +| ORx | Observation Receiver | +| PA | Power Amplifier | +| PCIe | Peripheral Component Interface Express | + +| | | +|------|--------------------------------------------| +| PDCP | Packet Data Convergence Protocol | +| PHY | Physical Layer, also referred as L1 | +| PLL | Phase Locked Loop | +| QAM | Quadrature Amplitude Modulation | +| QPSK | Quadrature Phase Shift Keying | +| QSFP | Quad Small Form-factor Pluggable | +| RAN | Radio Access Network | +| RF | Radio Frequency | +| RLC | Radio Link Controller | +| RRC | Radio Resource Controller | +| RU | Radio Unit as defined by 3GPP | +| RX | Receiver | +| SATA | Serial ATA | +| SDU | Service Data Unit | +| SFP | Small Form-factor Pluggable | +| SFP+ | Small Form-factor Pluggable Transceiver | +| SoC | System on Chip | +| SPI | Serial Peripheral Interface | +| SSD | Solid State Drive | +| TCXO | Temperature Compensated Crystal Oscillator | +| TDP | Thermal Design Power | +| TR | Technical Report | +| TS | Technical Specification | +| TX | Transmitter | +| UL | Uplink | +| USB | Universal Serial Bus | +| WG | Working Group | + +# 4 Deployment Scenarios and White Box Base Station Architecture + +This chapter consists of two parts: the deployment scenario and the white box architecture. The deployment scenarios outline more specific functional requirements of the base station. All the reference designs shall meet these requirements in order to comply with O-RAN white box standard. In the white box hardware architecture section, it describes the overall gNB hardware architecture and function partition that meet the design requirements. The details on each of these topics are described in the following sections. + +## 4.1 Deployment Scenarios + +The specification here addresses a specific deployment scenario defined by the white box Deployment Scenarios and Base Station Classes document [1]. Its requirements are also defined in [1]. Some of the key requirements described in that document are highlighted below: + +- Cell type: Enterprise Microcell +- Mounting Options: Rooftop, side of building/wall, pole +- Possible Carrier Frequency Bands: n41, n78 +- [Instantaneous] Bandwidth: Up to 100 MHz +- Antennas Configuration: Up to 8T8R +- Conducted Power: up to 20W per port +- Fronthaul Type: O-RAN FH (WG4) split option 7-2x +- Architecture: Split architecture + +## 4.2 White Box Base Station Architecture + +In general, the base station hardware architecture can be classified by using different criteria. The physical partition method is adopted by O-RAN; hence, the base station architecture is divided into two categories namely split and integrated. In split architecture, the fronthaul interface determines the gNB functions location. Here we refer to the two partitions as O-DU<sub>x</sub> and O-RU<sub>x</sub>; where the “x” is split option number. In case the O-RAN WG4 defined fronthaul interface is used, these two partitions are called O-DU<sub>7-2x</sub> and O-RU<sub>7-2x</sub>. For a more complete description of the terminology used, refer to the Deployment Scenarios and Base Station Classes Document [1]. + +For this implementation of Enterprise Microcell, the split architecture is used. With split architectures, the O-CU and O-DU<sub>x</sub> are integrated into one Whitebox, as shown in Figure 4.2-1. Optionally, a second O-RU may be cascaded to the first O-RU<sub>x</sub> via the FH interface. The FH interface between the two cascaded O-RUs shall be the same as the FH interface between the O-DU<sub>x</sub> and the first O-RU<sub>x</sub>. + +![Figure 4.2-1 Split Architecture diagram](342d1ccd941f7abe0e8c59ae90b8c128_img.jpg) + +The diagram illustrates the Split Architecture. On the left, a dashed blue box represents the 'Whitebox' containing the O-CU and O-DU<sub>x</sub> components, connected by an F1 Interface. A blue note below this box states 'O-CU & O-DU<sub>x</sub> are integrated into one Whitebox'. To the right, there are one or more O-RU<sub>x</sub> components. The O-DU<sub>x</sub> is connected to the first O-RU<sub>x</sub> via an FH Interface<sub>x</sub>. This first O-RU<sub>x</sub> is then connected to a second O-RU<sub>x</sub> via an FH Interface<sub>x</sub> 'Via Fiber Bypass'. Vertical ellipsis between the O-RU<sub>x</sub> boxes indicates that multiple O-RUs can be connected in a cascade. + +Figure 4.2-1 Split Architecture diagram + +**Figure 4.2-1 Split Architecture** + +# 5 Hardware Architecture + +In the white box hardware architecture section, it describes the overall gNB hardware architecture and function partition that meet the design requirements. The details on each of these topics are described in the following sections. + +## 5.1 O-CU Hardware Architecture + +In a 3GPP system architecture, the gNB Central Unit (CU) communicates to the Distribution Unit (DU) via an F1 interface. This interface has been adopted by O-RAN Alliance for O-CU and O-DU<sub>x</sub> connection. F1 is an IP based protocol interface, which offers more flexibility in the O-CU platform design. + +### 5.1.1 O-CU Architecture Diagram + +The O-CU can be implemented with any General-Purpose Processor (GPP) based platform having an optional hardware accelerator block. The O-CU functions can be implemented either on separated hardware platforms or on the same hardware platforms integrated with O-DU<sub>x</sub> functions. In either case, the O-CU hosts L2/L3 functions, whereas O-DU hosts L2/L1 functions which require different CPU, Storage, Acceleration and Networking capabilities. Figure 5.1-1 shows the hardware blocks and interfaces within the O-CU white box. + +![Figure 5.1-1 O-CU White Box Hardware Block Diagram. The diagram shows a dashed box labeled 'O-CU' containing three main components: 'Ethernet Interface' (left), 'Digital Processing Unit' (center), and 'Hardware Accelerator (Optional)' (right). Bidirectional arrows connect the left 'Ethernet Interface' to the 'Backhaul (Ethernet)' and the 'Digital Processing Unit'. Bidirectional arrows also connect the 'Digital Processing Unit' to the 'Hardware Accelerator (Optional)'. A third 'Ethernet Interface' is located below the 'Digital Processing Unit', connected to it by a bidirectional arrow. This bottom 'Ethernet Interface' is connected to the 'F1 Interface (Ethernet)' outside the box. The label 'O-CU' is placed at the bottom left of the dashed box.](0f541c8bdd1d232dba5bd2d572692db3_img.jpg) + +Figure 5.1-1 O-CU White Box Hardware Block Diagram. The diagram shows a dashed box labeled 'O-CU' containing three main components: 'Ethernet Interface' (left), 'Digital Processing Unit' (center), and 'Hardware Accelerator (Optional)' (right). Bidirectional arrows connect the left 'Ethernet Interface' to the 'Backhaul (Ethernet)' and the 'Digital Processing Unit'. Bidirectional arrows also connect the 'Digital Processing Unit' to the 'Hardware Accelerator (Optional)'. A third 'Ethernet Interface' is located below the 'Digital Processing Unit', connected to it by a bidirectional arrow. This bottom 'Ethernet Interface' is connected to the 'F1 Interface (Ethernet)' outside the box. The label 'O-CU' is placed at the bottom left of the dashed box. + +**Figure 5.1-1 O-CU White Box Hardware Block Diagram** + +### 5.1.2 O-CU Functional Module Description + +The O-CU functional architecture comprises Digital Signal Processing, optional HW Acceleration, and Connectivity units as well as memory and storage units as shown in Figure 5.1-1. + +### 5.1.3 O-CU Interfaces + +The O-CU interfaces through backhaul with the 5GC core network and via F1 interface with the O-DU<sub>7-2x</sub>. The backhaul and the F1 interfaces are typically implemented with GbE transport/connections. + +## 5.2 O-DU<sub>7-2x</sub> Hardware Architecture + +For a split RAN architecture, the functional blocks of the RAN physical layer are divided into two parts – high PHY and low PHY. The O-RAN lower layer split is defined in O-RAN WG4 fronthaul interface specification [4]. It also provides the details of the interface protocol as well as function partitions. + +### 5.2.1 O-DU<sub>7-2x</sub> Architecture Diagram + +Depending on the 3GPP standards and category of the radio unit, the split function blocks within O-DU<sub>7-2x</sub> and O-RU<sub>7-2x</sub> may vary accordingly. The O-RAN fronthaul C/U/S-plane specification [4] provides comprehensive information on this topic. The hardware functional partition architecture is shown in Figure 5.2-1. + +![Figure 5.2-1: O-DU7-2x with Split Physical Layer Function. The diagram shows the internal architecture of an O-DU7-2x unit. A dashed box labeled 'O-DU7-2x' contains a 'Hardware Accelerator' at the top, a 'Digital Processing Unit' in the center, and two 'Ethernet Interface' blocks on either side of the central unit. A 'Timing and Synchronization (IEEE 1588)' block is located below the central unit. External connections include an 'F1 Interface' on the left, an 'O-RAN FH Interface' on the right connecting to an 'O-RU7-2' unit, and a '1 PPS (IN or OUT)' input/output on the bottom right. Bidirectional arrows indicate data flow between the Hardware Accelerator and Digital Processing Unit, between the Digital Processing Unit and both Ethernet Interfaces, and between the two Ethernet Interfaces. Unidirectional arrows show data flow from the F1 Interface to the left Ethernet Interface, from the right Ethernet Interface to the O-RAN FH Interface, and from the Timing and Synchronization block to the right Ethernet Interface.](18ef10945e75bbfc200646c46ca71e7c_img.jpg) + +Figure 5.2-1: O-DU7-2x with Split Physical Layer Function. The diagram shows the internal architecture of an O-DU7-2x unit. A dashed box labeled 'O-DU7-2x' contains a 'Hardware Accelerator' at the top, a 'Digital Processing Unit' in the center, and two 'Ethernet Interface' blocks on either side of the central unit. A 'Timing and Synchronization (IEEE 1588)' block is located below the central unit. External connections include an 'F1 Interface' on the left, an 'O-RAN FH Interface' on the right connecting to an 'O-RU7-2' unit, and a '1 PPS (IN or OUT)' input/output on the bottom right. Bidirectional arrows indicate data flow between the Hardware Accelerator and Digital Processing Unit, between the Digital Processing Unit and both Ethernet Interfaces, and between the two Ethernet Interfaces. Unidirectional arrows show data flow from the F1 Interface to the left Ethernet Interface, from the right Ethernet Interface to the O-RAN FH Interface, and from the Timing and Synchronization block to the right Ethernet Interface. + +**Figure 5.2-1 O-DU<sub>7-2x</sub> with Split Physical Layer Function** + +### 5.2.2 O-DU<sub>7-2x</sub> Functional Module Description + +The choice of O-DU<sub>7-2x</sub> hardware components depends on the product design requirements and is outside the scope of this specification. Figure 5.2-2 shows the main components of O-DU<sub>7-2x</sub>. Their descriptions and requirements are as follows: + +#### Digital Processing Unit + +The processing unit can be any GPP or digital signal processor (DSP), with I/O chipset. It may also be in the form of System-On-Chip (SOC), or Multi-Chip Package (MCP). + +#### Memory + +DDR memory devices are used to store the runtime data and software for the processing unit. + +#### Flash Memory + +On board non-volatile storage device is used to store the firmware and non-volatile data, such as log data. + +#### Board Management Controller + +The controller is used to manage/control the power and monitors the operational status of the board. + +#### Storage Device + +The storage device such as hard drive is used to store OS, driver and applications software. + +#### Ethernet Controller + +The Ethernet ports transport the fronthaul or backhaul traffic according to the gNB hardware node requirements. The Ethernet device shall support IEEE1588 based timing synchronization. + +#### Hardware Accelerator + +The hardware accelerator is an optional device. For performance improvement, the hardware accelerator can be used to process computationally-intensive functions (e.g., Forward Error Correction (FEC)) and to offload the processor. + +![Figure 5.2-2 O-DU7-2x Functional Block and Interface Diagram. The diagram shows a central 'Digital Processing Unit' block. On the left, it connects to an 'Accelerator' via 'PCIe', 'USB Ports' via 'USB', 'Video Port' via 'VGA', 'PCIe Slots' via 'PCIe', 'Serial Ports' via 'RS232', and 'Timing' via 'Timing Signal'. On the right, it connects to 'DDR RAM' via 'Memory Channel', 'Flash Memory' via 'SPI', 'SMBus Port' via 'SMBus', 'Storage Drives' via 'SATA', and 'Ethernet Ports' via 'Ethernet'.](b22d295ebd15e76bb9fb6469c44b7ffa_img.jpg) + +Figure 5.2-2 O-DU7-2x Functional Block and Interface Diagram. The diagram shows a central 'Digital Processing Unit' block. On the left, it connects to an 'Accelerator' via 'PCIe', 'USB Ports' via 'USB', 'Video Port' via 'VGA', 'PCIe Slots' via 'PCIe', 'Serial Ports' via 'RS232', and 'Timing' via 'Timing Signal'. On the right, it connects to 'DDR RAM' via 'Memory Channel', 'Flash Memory' via 'SPI', 'SMBus Port' via 'SMBus', 'Storage Drives' via 'SATA', and 'Ethernet Ports' via 'Ethernet'. + +**Figure 5.2-2 O-DU<sub>7-2x</sub> Functional Block and Interface Diagram.** + +### 5.2.3 O-DU<sub>7-2x</sub> Interfaces + +The O-DU<sub>7-2x</sub> supported interfaces described below are also shown in Figure 5.2-2. + +#### Memory Channel Interface + +Support DDR4 and later memory interface. + +#### PCIe Interface + +Support for PCIe Gen3 x16 and later interface versions; the bandwidth depends on the use cases, and it can be used to connect an accelerator device or network card. + +#### Ethernet Interfaces + +Supports any one or combination of GbE/10GbE/25GbE/40GbE links. + +#### Serial ATA Interface + +SATA3 shall be supported in case of software storage, such as hard drive. + +#### SPI Interface + +The SPI interface connects the processor with flash type of device for firmware. + +#### Video Interface + +Video interface is optional + +#### USB Interface + +Used to connect with local device for debug or on-board firmware update. + +#### Miscellaneous Interface + +Other interfaces that may be needed such as serial port, JTAG, etc. + +## 5.3 O-RU<sub>7-2x</sub> Hardware Architecture + +This section provides the high-level architecture and functional module description of O-RU<sub>7-2x</sub>. + +### 5.3.1 O-RU<sub>7-2x</sub> Architecture Diagram + +O-RU<sub>7-2x</sub> consists of five modules, namely fronthaul processing unit, digital processing unit, RF processing unit, timing unit, and power unit, as shown in Figure 5.3-1. The digital processing unit handles all digital signals, and the RF processing unit handling all analog signals. There is a data conversion block for each transceiver path after the digital processing block which converts between digital signals and analog signals. The FH processing unit complies with O-RAN WG4 open fronthaul interface. There is at least two interface port available, one for connecting with O-DU<sub>7-2x</sub>, and the other for O-RU cascading. + +![Figure 5.3-1 O-RU7-2x Architecture Diagram](4f745312c4e8def1925335e4ff9afea9_img.jpg) + +The diagram illustrates the internal architecture of the O-RU<sub>7-2x</sub> unit. It is enclosed in a dashed box labeled 'O-RU<sub>7-2x</sub>'. Inside, five main functional blocks are shown: 'O-RAN FH Processing Unit', 'Digital Processing Unit', 'RF Processing Unit', 'Timing Unit', and 'Power Unit'. The 'O-RAN FH Processing Unit' has two external interfaces on the left: 'To/From O-DU<sub>7-2x</sub>' and 'To/From Cascaded O-RU<sub>7-2x</sub>', both connected via 'O-RAN FH Interface'. It is bidirectionally connected to the 'Digital Processing Unit', which in turn is bidirectionally connected to the 'RF Processing Unit'. The 'RF Processing Unit' has a bidirectional connection to the 'To/From Antenna' on the right. The 'Timing Unit' receives 'Local timing from CDR' (indicated by a blue dashed arrow) and 'Local timing from GNSS or equivalent' (indicated by a blue dashed arrow from an external 'GNSS (optional)' block). It provides timing signals to the 'O-RAN FH Processing Unit', 'Digital Processing Unit', and 'RF Processing Unit'. The 'Power Unit' at the bottom provides power to the 'Timing Unit', 'Digital Processing Unit', and 'RF Processing Unit'. + +Figure 5.3-1 O-RU7-2x Architecture Diagram + +**Figure 5.3-1 O-RU<sub>7-2x</sub> Architecture Diagram** + +### 5.3.2 O-RU<sub>7-2x</sub> Functional Module Description + +Figure 5.3-2 illustrates O-RU<sub>7-2x</sub> functional blocks that support O-RAN FH with split option 7-2x. The digital processing unit block of O-RU<sub>7-2x</sub> is responsible for low-PHY functions such as FFT/iFFT, CP addition/removal, and PRACH filtering. Digital Down Converter (DDC), Digital Up Converter (DUC), Crest Factor Reduction (CFR) and Digital Pre-Distortion (DPD) functions are also performed in digital processing unit. For bandwidth reduction, O-RU<sub>7-2x</sub> architecture also supports the optional compression and decompression functions of FH interface. The ADC and DAC are mixed signal devices responsible for conversion of data between the digital and analog domains. As such, this block can be included as part of the either the digital processing unit or the RF processing unit. The RF Processing Unit consists of an optional frequency converter (mixer), Power Amplifier (PA)/ Low Noise Amplifier (LNA) and TX/RX filters. An antenna module follows that comprises physical antennae, RF feed distribution/aggregation network, and calibration network. The timing unit includes any clock and frequency synthesis required as well as other timing and synchronization circuits. In any given implementation, the physical boundaries between blocks may be slightly different, but the logical interfaces will generally follow those shown in Figure 5.3-2. + +![Figure 5.3-2 O-RU7-2x Functional Module Diagram. The diagram shows the functional architecture of the O-RU7-2x. It is divided into three main processing units: FH Processing Unit, Digital Processing Unit, and RF Processing Unit. The FH Processing Unit includes an Optical Interface, eCPRI, and O-RAN FH/IEEE 1588v2. The Digital Processing Unit includes (De-) Compression Low-PHY, DDC/DUC, CFR/DPD, and ADC/DAC. The RF Processing Unit includes a Mixer, PA/LNA/ and TX/RX Filters, and an Antenna Module. A Timing Unit is connected to the O-RAN FH/IEEE 1588v2, (De-) Compression Low-PHY, DDC/DUC, CFR/DPD, and ADC/DAC blocks. A Power Unit is connected to the Timing Unit and the PA/LNA/ and TX/RX Filters block. The entire system is labeled O-RU7-2x.](e2cf0dcf37316b72723f66983494a2ae_img.jpg) + +Figure 5.3-2 O-RU7-2x Functional Module Diagram. The diagram shows the functional architecture of the O-RU7-2x. It is divided into three main processing units: FH Processing Unit, Digital Processing Unit, and RF Processing Unit. The FH Processing Unit includes an Optical Interface, eCPRI, and O-RAN FH/IEEE 1588v2. The Digital Processing Unit includes (De-) Compression Low-PHY, DDC/DUC, CFR/DPD, and ADC/DAC. The RF Processing Unit includes a Mixer, PA/LNA/ and TX/RX Filters, and an Antenna Module. A Timing Unit is connected to the O-RAN FH/IEEE 1588v2, (De-) Compression Low-PHY, DDC/DUC, CFR/DPD, and ADC/DAC blocks. A Power Unit is connected to the Timing Unit and the PA/LNA/ and TX/RX Filters block. The entire system is labeled O-RU7-2x. + +**Figure 5.3-2 O-RU<sub>7-2x</sub> Functional Module Diagram** + +# 6 Hardware Requirements + +This chapter provides the requirements for various white boxes used within the Enterprise Microcell base station. These white boxes are O-CU, O-DU<sub>x</sub> and O-RU<sub>x</sub>. In this version of the specification, the O-CU and O-DU<sub>x</sub> are implemented in an integrated fashion into one white box hardware. The reference design based on specification shall meet all these requirements based on their priority as specified by operators. + +## 6.1 O-CU Requirements + +The requirement for O-CU portion is captured in the following O-DU<sub>x</sub> section. + +## 6.2 O-DU<sub>x</sub> Common Requirements + +The common requirements apply to all the O-DU<sub>x</sub> regardless of the split option. However, in this version of the specification, the focus will be on O-DU<sub>7-2x</sub>. If more options get standardized in a future version of this document, some of these common requirements may be moved to the specific sub-sections in section 6.3. + +### 6.2.1 Performance + +The performance requirements of the O-DU<sub>7-2x</sub> for Enterprise Microcell are listed in Table 6.2-1, including the channel bandwidth, antenna configuration, transmission distance, synchronization, etc. + +**Table 6.2-1 O-DU<sub>7-2x</sub> Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------------------------------------|--------------------------------|--------------------------------|----------| +| Channel Bandwidth | ≤200 MHz OBW | RF Bandwidth | High | +| Antenna Configuration<br>(Number of Transceivers) | up to 8T8R | Tx/Rx antenna number | High | +| Transmission distance | >2 km | Distance between O-DU and O-RU | High | +| Synchronization | Support 1588v2 Synchronization | Timing synchronization | High | + +| | | | | +|---------------|-------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|--------| +| | Support GPS Synchronization | method | High | +| | Support BeiDou Synchronization | | High | +| | Support Galileo Synchronization | | Low | +| | Support GLONASS Synchronization | | Low | +| | Support switching between 1588v2 and GNSS | | High | +| | Support SyncE | | Low | +| | Sync. between BS $\leq \pm 1.5$ us; Carrier freq. error within one subframe $\leq \pm 0.05$ PPM | | High | +| Capacity/MIMO | Support at least 4 100MHz bandwidth 4T4R cells | MIMO related capability | High | +| Peak Rate | With 100MHz bandwidth and 64% for DL, the peak throughput of one cell:<br>DL: 1.5Gbps (4 layers, 256QAM)<br>UL: 280Mbps (2 layers, 64QAM) | Peak data rate | High | +| Modulation | DL: QPSK, 16QAM, 64QAM, 256QAM<br>UL: $\pi/2$ -bpsk, QPSK, 16QAM, 64QAM | Modulation schemes | High | +| | UL: 256QAM | | Medium | +| Latency | Control Plane < 10ms (def: Msg1 to Msg5)<br>User Plane DL < 4ms UL < 4ms (def: PDCP SDU-> PDCP SDU) | Control/user plane Latency | High | + +### 6.2.2 Interfaces + +The interface requirements of the O-DU<sub>7-2x</sub> are listed in Table 6.2-2. + +**Table 6.2-2 O-DU<sub>7-2x</sub> Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------|---------------------------------------------------------------------|-----------------|----------| +| Transport Interface | 10 GbE or 25GbE NG interface to connect with 5G core | transport links | High | +| | At least 4 fronthaul interfaces connected with O-RU <sub>7-2x</sub> | | High | + +### 6.2.3 Environmental and EMC + +The EMC requirements of the O-DU<sub>7-2x</sub> are listed in Table 6.2-3. + +**Table 6.2-3 O-DU<sub>7-2x</sub> EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------|-----------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| EMC | Complying with the requirements of 3GPP TS 38.113 (2017-12R15) [6] for equipment used in telecommunication room | Electromagnetic Compatibility requirement | High | + +### 6.2.4 Mechanical, Thermal and Power + +The mechanical requirements of the O-DU<sub>7-2x</sub> are listed in Table 6.2-4. + +**Table 6.2-4 O-DU<sub>7-2x</sub> Mechanical Requirements** + +| Parameter | Requirement | Description | Priority | +|----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------|----------| +| Dimension | Built in any 19" standard rack, or stand alone, and the height does not exceed 2U, the depth (including the connector) must be less than 750mm. | Measurement in three dimensions | High | +| Status Indicator LED | At least include the following status indicators:<br>---1 indicating on/off status of the power supply<br>---1 indicating on/off status of the transmission link | Indicator lights | High | + +The thermal requirements of the O-DU<sub>7-2x</sub> are listed in Table 6.2-5. + +**Table 6.2-5 O-DU<sub>7-2x</sub> Thermal Requirements** + +| Parameter | Requirement | Description | Priority | +|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------|----------| +| Temperature and Humidity | The O-DU <sub>7-2x</sub> shall operate steadily and reliably over a long period of time under the following environmental conditions for data center:<br><br>Operating Temperature: -5 °C ~ + 55 °C<br>Relative humidity: 15% ~ 85% | Environmental requirements for reliability | High | +| | The solution should support extended temperature range (-40°C to +65 °C) and humidity (5%-95%) if implemented outdoors. | Environmental requirements for reliability | Low | + +The power requirements of the O-DU<sub>7-2x</sub> are listed in Table 6.2-6. + +**Table 6.2-6 O-DU<sub>7-2x</sub> Power Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------|-------------------|----------| +| Power Supply | DC -48 VDC (-40V ~ -57V) (can be connected to AC/DC converter) or AC 220V power supply, voltage range of 140V~300V, frequency range of 45Hz ~ 65Hz. | Power supply | High | +| Power Dissipation | < 480 W, with full load operation | Power Requirement | Medium | + +## 6.3 O-DU<sub>x</sub> Split Option Specific Requirements + +‘This section intentionally left blank’. + +## 6.4 O-RU<sub>x</sub> Requirements + +The common requirements apply to all the O-RU<sub>x</sub> regardless of the split option. However, in this version of the specification, the focus will be on O-RU<sub>7-2x</sub>. If more options get standardized in a future version of this document, some of these common requirements may be moved to the specific sub-sections in section 6.5. + +### 6.4.1 Performance + +The O-RU<sub>7-2x</sub> performance requirements cover all the aspects of radio unit including frequency bands, antenna configurations, power efficiency, etc. Table 6.4-1 lists the performance parameters related to O-RU<sub>7-2x</sub> for Enterprise Microcell. + +**Table 6.4-1 O-RU<sub>7-2x</sub> Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------|----------| +| Operating band | n78, n41 | Radio frequency band | High | +| [Occupied] Bandwidth | ≤200 MHz | Frequency bandwidth | High | +| Antenna Configuration (Number of Transceivers) | Up to 8T8R | Tx/Rx Antenna numbers | High | +| Output Power Accuracy | Under normal condition: ±2dB | Power accuracy | High | +| Tx off Power Level | less than -85dBm/MHz; See section 6.4.1 in 3GPP TS 38.104 [3]. | Tx power level during an off period | High | +| EVM at maximum output power | 64QAM: EVM smaller than 5%<br>256QAM: EVM smaller than 3.5% | Max output power | High | +| Operating band unwanted emissions | The Operating band unwanted emissions shall satisfy the Category B limit defined by the section 6.6.4.2.4 in 3GPP TS 38.104 [3]. | RF operation band unwanted emissions requirement | High | +| Transmitter spurious emissions | The Operating band unwanted emissions shall satisfy the Category B limit defined by the section 6.6.4.2.4 in [3]. | Deliberately generated RF signal by transmitter | High | +| Receiver Sensitivity | The throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel of G-FR1-A1-5; the reference sensitivity levels shall be better than -95.6dBm. | The weakest signal the receiver can identify and process | High | +| Blocking | In Channel selection, ACS, In-band blocking, out-band blocking, IMD and other receiver specification shall follow the 3GPP guidelines in [3], the reference sensitivity is allowed to degrade at most 6dB under all kinds of interference signal and corresponding level. | Channel selection related requirement | High | +| Other specifications | Except for all the RF specifications listed above, other RF specifications shall follow the requirement in [3]. | Additional standard to comply | High | +| Downlink modulation Mode | QPSK、16-QAM、64-QAM、256-QAM | DL Modulation schemes | High | +| Uplink modulation | $\pi/2$ -BPSK、QPSK、16-QAM、64-QAM | UL Modulation | High | + +| | | | | +|-----------------|--------------------|----------|--------| +| mode | 256QAM | schemes | Medium | +| Conducted Power | Up to 20W per port | RF power | High | +| EIRP | NA | | | + +### 6.4.2 Interfaces + +The interface related requirements of the O-RU<sub>7-2x</sub> are listed in Table 6.4-2. + +**Table 6.4-2 O-RU<sub>7-2x</sub> Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|------------------|-------------------------------------------------------------------------------------------------|---------------------------|----------| +| Interface Number | The O-RU <sub>7-2x</sub> shall have one fronthaul interface based on the split option supported | Number of fronthaul links | High | +| | The O-RU <sub>7-2x</sub> shall have one optical interface for cascade | Number of transport links | High | + +### 6.4.3 Environmental and EMC + +The environmental and EMC requirements of the O-RU<sub>7-2x</sub> are listed in Table 6.4-3. + +**Table 6.4-3 O-RU<sub>7-2x</sub> Environmental and EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| Mounting method | Rooftop, side of building/wall or pole | Mounting requirement | High | +| Grounding | The O-RU <sub>7-2x</sub> shall support Joint Grounding Method and shall work normally when the grounding resistor is less than 10Ω. | Grounding requirement | High | +| EMC | The O-RU <sub>7-2x</sub> shall comply with the requirements of 3GPP TS 38.113 [6]. | Electromagnetic Compatibility requirement | High | + +### 6.4.4 Mechanical, Thermal and Power + +The mechanical, thermal and power requirements of the O-RU<sub>7-2x</sub> are listed in Table 6.4-4. + +**Table 6.4-4 O-RU<sub>7-2x</sub> Mechanical, Thermal and Power Requirements** + +| Parameter | Requirement | Description | Priority | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------|----------| +| Weight | The gross weight of the O-RU <sub>7-2x</sub> shall be <12Kg | Weight requirement | High | +| Dimension/Volume | The volume of the O-RU <sub>7-2x</sub> shall be <12L | Dimensional Measurements | High | +| Stability | The MTBF shall be >200000 hours | Mean Time Between Failures | High | +| Power Consumption | At full load, the power consumption shall not exceed 200W | Power requirement | High | +| Power supply | DC -48 VDC (-40v ~ -57v) (can be connected to AC/DC converter) or AC 220V power supply, voltage range of 140V~ 300V, frequency range of 45Hz ~ 65Hz. | Power Support Requirement | High | +| Level of protection | The protection level of the O-RU <sub>7-2x</sub> shall be equivalent to the IP65 standard. | Protection level | High | +| Temperature and Humidity | The O-RU <sub>7-2x</sub> shall operate at the temperature range of -40°C to +55°C with both cold start and hot start options. Humidity : 5%~95% | Ambient temperature and moisture requirement | High | +| Atmospheric pressure | The O-RU <sub>7-2x</sub> shall operate normally under atmospheric pressure between 70 to 106Kpa. | Operational atmospheric pressure requirement | High | +| Cooling mode | Passive cooling | System cooling requirement | High | + +## 6.5 O-RUx Split Option Specific Requirements + +‘This section intentionally left blank’. + +# 7 Hardware Reference Design + +This chapter describes one example of white box hardware reference design including O-CU, O-DU and O-RU. + +## 7.1 O-CU Hardware Reference Design + +The O-CU white box hardware is the platform that perform the O-CU function of upper L2 and L3. The hardware systems specified in this document meet the computing, power and environmental requirements of use cases configurations and feature sets of RAN physical node. These requirements are described in chapter 6 of this document. For enterprise scenarios, the UPF and/or MEC platform can also be deployed in the O-CU hardware in + +order to meet various industrial requirements. + +The O-CU hardware includes the chassis platform, mother board, peripheral devices, and cooling devices. The mother board contains processing unit, memory, the internal I/O interfaces, and external connection ports. The midhaul (MH) and backhaul (BH) interface are used to carry the traffic between O-CU and O-DU as well as O-CU and core network. The other hardware functional components include: the storage for software, hardware and system debugging interfaces, board management controller, just to name a few; the O-CU designer will make decision based on the specific needs of the implementation. + +The HW reference design of O-CU is the same as O-DU except for the need of HW accelerator, thus detail design will be described in the next section. + +## 7.2 O-DU<sub>7-2x</sub> Hardware Reference Design 1 + +The O-DU<sub>7-2x</sub> white box hardware is the platform that performs the O-DU<sub>7-2x</sub> functions such as upper L1 and lower L2 functions. The hardware systems specified in this document meet the computing, power and environmental requirements of use case's configurations and feature sets of RAN physical node. These requirements are described in chapter 6 of this document. The O-DU<sub>7-2x</sub> hardware includes the chassis platform, mother board, peripheral devices, and cooling devices. The mother board contains processing unit, memory, the internal I/O interfaces, and external connection ports. The fronthaul and backhaul interface are used to carry the traffic between O-RU<sub>7-2x</sub> and O-DU<sub>7-2x</sub> as well as O-CU and O-DU<sub>7-2x</sub>. The O-DU<sub>7-2x</sub> design may also provide an interface for hardware accelerator if that option is preferred. The other hardware functional components include: the storage for software, hardware and system debugging interfaces, board management controller, just to name a few. The O-DU<sub>7-2x</sub> designer will make decisions based on the specific needs of the implementation. + +Note that the O-DU<sub>7-2x</sub> HW reference design is also feasible for O-CU and integrated O-CU/O-DU<sub>7-2x</sub>. + +### 7.2.1 O-DU<sub>7-2x</sub> High-Level Functional Block Diagram + +For this example, a dual-socket platform is used. In the following O-DU<sub>7-2x</sub> mother board functional block diagram, it shows the interconnections of the major components and external interfaces. The digital processing unit or CPU handles the baseband processing workload. To make the processing more efficient, an accelerator can be used to assist with the baseband workload processing. The memory devices include the random-access memory (RAM) for temporary storage of data while flash memory is used for codes and logs. The storage device is for persistent storage. The external network cards can be used for fronthaul or backhaul connection. The baseband management controller (BMC) is a microcontroller which monitors hardware operation on motherboard. + +![Figure 7.2-1 O-DU7-2x Functional Block Diagram](2d269f0c746da6be44e39f4da6abbbb6_img.jpg) + +The diagram illustrates the functional block diagram of the O-DU<sub>7-2x</sub> hardware. It features two main processing units, CPU 1 and CPU 2, connected via UPI 9.6GT/s interfaces. Each CPU is connected to DDR memory. CPU 1 is also connected to PCIe 3.0 interfaces and NVMe storage. A Platform Controller Hub (PCH) is connected to both CPUs and manages various external interfaces, including USB \*6, LAN port \*4, Ethernet Transceiver, SATA/NVMe, and a Baseband Management Controller (BMC). The BMC is connected to LAN, COM, VGA, and SPI Flash interfaces. + +Figure 7.2-1 O-DU7-2x Functional Block Diagram + +**Figure 7.2-1 O-DU<sub>7-2x</sub> Functional Block Diagram** + +### 7.2.2 O-DU<sub>7-2x</sub> Hardware Components + +#### 7.2.2.1 Digital Processing Unit + +The example of general-purpose processor performances and other related information are list in the following table. + +**Table 7.2-1 Processor Feature List** + +| Item Name | Description | +|--------------------------------------------|-------------| +| # of Cores | 16 | +| # of Threads | 32 | +| Base Frequency | 2.30 GHz | +| Max Turbo Frequency | 3.70 GHz | +| Cache | 22 MB | +| TDP | 110W | +| Max Memory Size (dependent on memory type) | 1 TB | +| Memory Types | DDR4 | +| Max # of Memory Channels | 6 | +| Sockets Supported | LGA-3647 | + +The interface specifications on the main board are as follows: + +**Memory Channel Interfaces:** The system memory capacity, type and related information is described in the following table. + +**Table 7.2-2 Memory Channel Feature List** + +| Item Name | Description | +|----------------------|-------------------| +| Memory Types | DDR4 RDIMM/LRDIMM | +| # of Memory Channels | 6 | +| Support ECC | Yes | +| Maximum Memory Speed | 2667 MHz | +| Memory Voltage | 1.2 V | + +**PCIe:** PCIe Gen 3 is supported by the processor. There are total of 48 PCIe lanes for each processor. + +**Ethernet:** The system provides 4\*1Gbps Ethernet ports. When higher Ethernet bandwidth required, an Ethernet card can be installed in one of the PCIe slot. + +#### 7.2.2.2 Hardware Accelerator + +Hardware accelerators can be used in O-DU<sub>7-2x</sub> to offload computationally intensive functions and to optimize the performance under varying traffic and loading conditions. While the hardware acceleration functional + +requirements and implementation are system designer's choice, the O-DU<sub>7-2x</sub> is required to meet the minimum system performance requirements under various loading conditions and deployment scenarios. + +For this example, the accelerator comprises a single FPGA for L1 offload and the fronthaul connectivity. The accelerator hardware and firmware features are listed in Table 7.2-3 and Table 7.2-4. + +**Table 7.2-3 Accelerator Hardware Features** + +| | | +|---------------------------------|-----------------------------------------------------------------------------------------------------------------------------------| +| SoC Resources | System Logic cells – 2,586 K<br>CLB LUT – 1,182K<br>CLB Flip-Flops -2,364K<br>DSP Slices - 6,840<br>BRAM - 75.9Mb<br>URAM - 270Mb | +| Form Factor | HHHL PCIe Form Factor | +| PCIe Interface | Gen 3 x16 | +| Memory | 8 GB DDR4 | +| Fronthaul interface | 4*10G/25G eCPRI interfaces | +| Timing Interface | SMA port for GNSS antenna;<br>optical port for IEEE1588v2 synchronization;<br>2*RJ45 port for 1PPS&TOD (in & out) | +| Other External Interface(s) | Micro USB for JTAG support (FPGA programming and debug) and access to BMC | +| Board Management Controller | Telemetry, Security, Remote Upgrade | +| Operating Temperature (ambient) | -5°C to +55°C | +| Power | < 110 W | + +**Table 7.2-4 Hardware Accelerator Firmware Features** + +| | | +|--------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Remote System Upgrade | Securely upgradable FPGA flash image | +| L1 Acceleration | 5G NR LDPC encoding/decoding with interleaving/de-interleaving and rate-matching/rate-de-matching along with early termination, CRC attachment, and HARQ management | +| Fronthaul Protocols | Support O-RAN FH (WG4) split option 7-2x | +| Synchronization | Support synchronization and timing | +| Open Programmable Acceleration Environment | Support for: <ul style="list-style-type: none"> <li>FPGA flashing upgrade</li> <li>Firmware version reporting</li> <li>PCIe diagnostics</li> <li>Ethernet diagnostics</li> <li>Temperature and voltage telemetry information</li> </ul> | + +Figure 7.2-2 illustrates the single-chip acceleration architecture comprising one FPGA with Gen3 x16 PCIe interfaces toward the Digital Processing Unit. + +![Figure 7.2-2 Single-chip FPGA-based Hardware Acceleration in O-DU7-2x. The diagram shows a block diagram of the hardware acceleration architecture. It consists of two main blocks: 'Digital Processing Unit (L2 and Partial L1)' and 'FPGA (L1 Offload, Connectivity & Sync)'. The Digital Processing Unit is connected to the FPGA via a 'PCIe Interface Gen3 *16'. The Digital Processing Unit has an 'F1 Interface 10G/25G Ethernet' on the left. The FPGA has 'Clock Signals' output and a 'Fronthaul Interface eCPRI' on the right.](03372371b2317aeec4e35c57e1b1aa08_img.jpg) + +Figure 7.2-2 Single-chip FPGA-based Hardware Acceleration in O-DU7-2x. The diagram shows a block diagram of the hardware acceleration architecture. It consists of two main blocks: 'Digital Processing Unit (L2 and Partial L1)' and 'FPGA (L1 Offload, Connectivity & Sync)'. The Digital Processing Unit is connected to the FPGA via a 'PCIe Interface Gen3 \*16'. The Digital Processing Unit has an 'F1 Interface 10G/25G Ethernet' on the left. The FPGA has 'Clock Signals' output and a 'Fronthaul Interface eCPRI' on the right. + +**Figure 7.2-2 Single-chip FPGA-based Hardware Acceleration in O-DU<sub>7-2x</sub>** + +### 7.2.3 Synchronization and Timing + +This section describes the synchronization and timing mechanism that is used in the hardware accelerator. + +Each hardware accelerator that supports connectivity functions (e.g., O-RAN fronthaul) in O-DU<sub>7-2x</sub> must be able to support external synchronization I/O and to receive or transmit 1 PPS reference clock source in order to ensure synchronization across network. + +The accelerator has a built-in DPLL, it can support GNSS, IEEE1588v2 or external reference signals as clock inputs, and output accurate frequency and synchronization signals to internal and external devices. When all reference inputs failed, the OCXO module can assist the accelerator to maintain high precision output signals for a certain period of time. Figure 7.2-3 describes the synchronization mechanisms of the accelerator. + +![Figure 7.2-3 HW Accelerator Timing and Synchronization. This block diagram illustrates the internal synchronization and timing mechanisms of the hardware accelerator. Key components include: 'DPLL' (Digital Phase-Locked Loop) which receives '10M trigger' and '1pps test' signals; 'OCXO' (Oven Controlled Crystal Oscillator) providing 'Sysclk' to the DPLL; 'FPGA' containing a 'Clock' block and a '1G/10G MAC'; and various external interfaces. The DPLL outputs '1pps' and 'ToD' (Time of Day) signals to a 'Connector'. The FPGA's 'Clock' block receives '1pps' and 'ToD' signals and outputs 'PTP' (Precision Time Protocol) signals. The '1G/10G MAC' receives 'SyncE' and 'IEEE1588v2+SyncE' signals from a 'Clock Source' and outputs '1pps' and 'ToD' signals to another 'Connector'. The 'Connector' also receives 'GNSS' signals. The 'other O-DU' block provides '1pps/ToD' signals to the 'Connector'.](cc74300c08a973cf447e7a07f4db03f3_img.jpg) + +Figure 7.2-3 HW Accelerator Timing and Synchronization. This block diagram illustrates the internal synchronization and timing mechanisms of the hardware accelerator. Key components include: 'DPLL' (Digital Phase-Locked Loop) which receives '10M trigger' and '1pps test' signals; 'OCXO' (Oven Controlled Crystal Oscillator) providing 'Sysclk' to the DPLL; 'FPGA' containing a 'Clock' block and a '1G/10G MAC'; and various external interfaces. The DPLL outputs '1pps' and 'ToD' (Time of Day) signals to a 'Connector'. The FPGA's 'Clock' block receives '1pps' and 'ToD' signals and outputs 'PTP' (Precision Time Protocol) signals. The '1G/10G MAC' receives 'SyncE' and 'IEEE1588v2+SyncE' signals from a 'Clock Source' and outputs '1pps' and 'ToD' signals to another 'Connector'. The 'Connector' also receives 'GNSS' signals. The 'other O-DU' block provides '1pps/ToD' signals to the 'Connector'. + +**Figure 7.2-3 HW Accelerator Timing and Synchronization** + +### 7.2.4 External Interface Ports + +The following table shows the external ports or slots that the system provided. + +**Table 7.2-5 External Port List** + +| Port Name | Feature Description | +|-------------|-----------------------------------| +| Ethernet | 1 x 1GbE RJ45 for management | +| | 4 x 1GbE RJ45 | +| PCIe | 4 PCIe 3.0 x16 slots | +| | 1 PCIe 3.0 x8 slots | +| | 2 PCIe 3.0 x16 slots (with riser) | +| Storage | 6 SAS/SATA/NVMe ports | +| USB | 4 USB 3.0 ports | +| | 2 USB 2.0 ports | +| VGA | 1 VGA port | +| Serial Port | 1 COM port | + +### 7.2.5 O-DU<sub>7-2x</sub> Firmware + +BIOS and BMC firmware are needed in the system and shall be installed. + +### 7.2.6 Mechanical + +#### 7.2.6.1 Mother Board + +The mechanical layout of the mother board shows the location of major components and interface ports. + +![Mother Board Layout Diagram showing components like CPU1, CPU2, DDR, PCIe, PCH, BHC, and various connectors.](07fb24eff70572df4ec20114b90a904a_img.jpg) + +The diagram illustrates the layout of a mother board. It features two main processing units, CPU1 and CPU2, each surrounded by multiple DDR memory modules. A central PCH (Platform Controller Hub) is connected to various PCIe slots (PCIe 1 through PCIe 6). Other components include a BHC (Baseband Hardware Controller), a USB port, and several SATA ports. Power connectors for ATX12V and ATX PWR are shown, along with four fans (FAN1, FAN2, FAN3, FAN4) for cooling. The layout is organized to optimize airflow and component placement within a 2U rack mount chassis. + +Mother Board Layout Diagram showing components like CPU1, CPU2, DDR, PCIe, PCH, BHC, and various connectors. + +**Figure 7.2-4 Mother Board Layout Diagram** + +#### 7.2.6.2 Chassis + +The 2U rack mount chassis contains the layout of the power supply, storage, and fans. The dimension of the hardware system is 450\*446\*87 (mm), and the weight is less than 25kg. + +#### 7.2.6.3 Cooling + +The system installs 4x 80\*38 PWM fans for the cooling. + +### 7.2.7 Power Unit + +In a fully loaded system, including the hardware acceleration card, the system power consumption should be less than 480W. The total system power shall be kept at less than 80% of the power supply capacity. + +The power is provided by 1+1 CPRS 550W/800W (80Plus Platinum) power supply. Table 7.2-6 lists the power requirements of O-DU<sub>7-2x</sub>. + +**Table 7.2-6 O-DU<sub>7-2x</sub> Power Requirements** + +| Supply Domain | Requirements | +|---------------|-------------------| +| AC Input | 100-240V, 50-60Hz | +| DC Input | 240VDC | +| | Support -48V | + +### 7.2.8 Thermal + +Active cooling with up to 4 fans is integrated in the chassis. + +The hardware acceleration cards use passive cooling and a custom heatsink and is equipped with temperature sensors. It is designed to operate in temperatures ranging from -5°C to +55°C. + +### 7.2.9 Environmental and Regulations + +The O-DU<sub>7-2x</sub> hardware system is RoHS Compliant. The power supply unit is EMC FCC/CISPR Class B compliant. Table 7.2-7 lists the environmental related features and parameters. + +**Table 7.2-7 Environmental Features** + +| Item Name | Description | +|---------------------------------|----------------------------| +| Operating Temperature | -5°C to +55°C | +| Non-operating Temperature | -40°C to 70°C | +| Operating Relative Humidity | 8% to 90% (non-condensing) | +| Non-operating Relative Humidity | 5% to 95% (non-condensing) | + +The hardware accelerator described in Section 7.2.2.2 is designed to operate in indoor environments and in temperatures ranging from -5°C to +55°C. + +## 7.3 O-DU<sub>7-2x</sub> Hardware Reference Design 2 + +### 7.3.1 O-DU<sub>7-2x</sub> High-Level Functional Block Diagram + +Figure 7.3-1 describes the components and connections inside the O-DU<sub>7-2x</sub> white box. As described in the previous section, the O-DU<sub>7-2x</sub> hardware can be implemented with difference design choices. Here, a system design is presented as an example which processes most of the O-DU<sub>7-2x</sub> workload. The accelerator can be used to perform some O-DU<sub>7-2x</sub> workload functions based on the overall performance requirement. Several Ethernet controllers are used for front haul link, back haul link and remote console control connection. The other parts include: RAM, flash memory, and hard drive storage. The USB ports are provided for hardware debug and local connection if needed. Finally, BMC block is mainly responsible for monitoring the hardware status. + +The digital processing unit is a system which includes a 64-bit multi-core server class processor, integrated high-speed I/O, Integrated Memory Controllers (IMC), a PCIe Switch, and a BMC. The system supports double channel 128-bit wide processing instruction set. It also supports hardware virtualization to enable dynamic provisioning of services as communication service providers extend network functions virtualization (NFV). Figure 7.3-1 shows the major functional blocks of the digital processing unit. + + + +#### 7.3.2.3 Baseboard Management Controller + +BMC is used to perform hardware power control (power on, power off and power cycle), monitor hardware status (temperatures, voltages, etc.), monitor Basic I/O System (BIOS)/ Unified Extensible Firmware Interface (UEFI) firmware status, and log system events. It provides remote access via shared or dedicated NIC. System user can do console access via serial or physical/Kernel-based Virtual Machine (KVM). The BMC has dedicated RAM and flash memory. It provides access via serial port or Ethernet port. Figure 7.3-1 describes the BMC connections with related components. + +### 7.3.3 Synchronization and Timing + +Refer to section 7.2.3. + +### 7.3.4 External Interface Ports + +The following table shows the external ports or slots that the system provided. + +**Table 7.3-3 External Port List** + +| Item Name | Description | +|--------------|-------------------------------------------------------------| +| Ethernet | 4x Gigabit Ethernet LAN connectors | +| | 1GbE IPMI RJ45 port | +| | Dual 10GbE SFP or Dual 25GE SFP28 Faber Ethernet connectors | +| | 6x25G SFP28 or 6x10G SFP | +| USB | 5 USB 3.0 ports | +| Serial Port | 1 DB9 COM port | +| Antenna port | 1 SMA connector for GNSS | +| VGA | 1 VGA port | + +### 7.3.5 O-DU<sub>7-2x</sub> Firmware + +BIOS and BMC firmware are needed in the system and shall be installed. + +### 7.3.6 Mechanical + +The mechanical design for mother board, chassis, and cooling are listed in this section. + +#### 7.3.6.1 Mother Board + +The mechanical layout of the mother board shows the location of major components and interface ports. The following diagram also provides the dimension of the board is standard E-ATX/EEB/CEB (13\*12 inch). + +![Figure 7.3-2 Mother Board Layout Diagram. A detailed schematic of a mother board layout with various components labeled. The board is 12 inch wide and 13 inch high. Components include: BMC (Baseboard Management Controller), BMC UART, BMC RSTBTN, USB3, USB3+RJ45, RJ45, RJ45, VGA+COM, UIDBTN, I2C HEADER, M.2, M.2, LPC HEADER, CPLD JTAG, MEZZ CONN, MINI PCIE, RSTBTN, PWRBTN, BEEP, FP USB2.0, FP VGA, F-PANEL, FP USB3.0, PCIE SWITCH, SATA, SATA, FAN1, FAN2, FAN3, FAN4, CPU, CPU FAN, CPU UART, PMBUS HEADER, ATX 24PIN, ATX 8PIN, CPU UART, PMBUS HEADER, ATX 24PIN, CPU UART, PMBUS HEADER, ATX 24PIN, CPU UART, PMBUS HEADER, ATX 24PIN. The board is populated with multiple DDR4 DIMM modules, PCIE slots, and various headers and buttons.](a81b5b876149f0126687fce63344420e_img.jpg) + +Figure 7.3-2 Mother Board Layout Diagram. A detailed schematic of a mother board layout with various components labeled. The board is 12 inch wide and 13 inch high. Components include: BMC (Baseboard Management Controller), BMC UART, BMC RSTBTN, USB3, USB3+RJ45, RJ45, RJ45, VGA+COM, UIDBTN, I2C HEADER, M.2, M.2, LPC HEADER, CPLD JTAG, MEZZ CONN, MINI PCIE, RSTBTN, PWRBTN, BEEP, FP USB2.0, FP VGA, F-PANEL, FP USB3.0, PCIE SWITCH, SATA, SATA, FAN1, FAN2, FAN3, FAN4, CPU, CPU FAN, CPU UART, PMBUS HEADER, ATX 24PIN, ATX 8PIN, CPU UART, PMBUS HEADER, ATX 24PIN, CPU UART, PMBUS HEADER, ATX 24PIN, CPU UART, PMBUS HEADER, ATX 24PIN. The board is populated with multiple DDR4 DIMM modules, PCIE slots, and various headers and buttons. + +**Figure 7.3-2 Mother Board Layout Diagram** + +#### 7.3.6.2 Chassis + +The 2U rack mount chassis contains the layout of the power supply which support 2 CRPS power supply, Hard disk drive and Solid State Drive (SSD) and fans. The chassis dimension is showed in following figure. + +![3D perspective view of the 2U rack mount chassis. The chassis is shown with its internal components. Callouts indicate: CRPS Power Supply*2, 80*38mm system fan *4, 2.5' HDD/SSD bay *6. Dimensions are shown: 445mm (width), 450mm (depth), and 87mm (height).](619e3c03012f1d224bd8717769f3a0ec_img.jpg) + +3D perspective view of the 2U rack mount chassis. The chassis is shown with its internal components. Callouts indicate: CRPS Power Supply\*2, 80\*38mm system fan \*4, 2.5' HDD/SSD bay \*6. Dimensions are shown: 445mm (width), 450mm (depth), and 87mm (height). + +**Figure 7.3-3 Chassis Mechanical Diagram** + +#### 7.3.6.3 Cooling + +The system installs 4\* 80x38mm PWM fans for the cooling. (Support 4 pcs 80x38 fan is standard configuration, and 4 pcs 80\*56mm system as optional) + +### 7.3.7 Power Unit + +In a fully loaded system which 3 PCIe slots, which contain 1 PCIe X16 slot support 75W power is standard power configuration, and system power supply have additional power 8pin/6pin cable to support special PCIe device which need more than 75W, and the other 2 PICE X8 slot can support 25W is compliant to standard PCIe Criteria. + +1. The X16 PCIe card support full high full long dimension. (DWFHFL) +2. The 2 X8 PCIe card support full high half long dimension (SWFHHL), +3. Additional, if X16 card is double size, there only one PCIe X8 supported. +4. The Unit support 2 CRPS 800W high-efficiency Power supply, redundancy design. + +The O-DU<sub>7-2x</sub> chassis includes two 550W/800W CRPS power supply unit (Support 1+1 redundancy design). The power supply unit is auto-switching capable, which enables it to automatically sense and operate at a 100v to 240v input voltage. The power supply unit features are listed in the following table. + +**Table 7.3-4 Power supply unit feature list** + +| Item Name | Description | +|-----------------------------|----------------------------------------------------------------| +| Output connectors | 24pin/8pin/4pin/I2C | +| Dimension (W x D x H) | 77 x 225 x 84 mm(CRPS criteria) | +| Maximum Output Power | +3.3V: 25A<br>+5V: 25A<br>+12V: 65A<br>-12V: 0.5A<br>+5Vsb: 3A | +| Rated Input Voltage/Current | 100-240Vac / 10-5A | +| Rated Input Frequency | 50/60HZ | +| Inrush current | Less than 30A | + +### 7.3.8 Thermal + +Active cooling with up to 4 fans is integrated in the chassis. + +The hardware acceleration cards use passive cooling and a custom heatsink and is equipped with temperature sensors. It is designed to operate in temperatures ranging from -5°C to +55°C. + +### 7.3.9 Environmental and Regulations + +The O-DU<sub>7-2x</sub> hardware system is RoHS Compliant. The power supply unit is EMC FCC/CISPR Class B compliant. Table 7.3-5 lists the environmental related features and parameters. + +**Table 7.3-5 Environmental Features** + +| Item Name | Description | +|-----------------------------|----------------------------| +| Operating Temperature | -5°C to +45°C | +| Non-operating Temperature | -20°C to +60°C | +| Operating Relative Humidity | 8% to 90% (non-condensing) | + +| | | +|---------------------------------|----------------------------| +| Non-operating Relative Humidity | 5% to 95% (non-condensing) | +|---------------------------------|----------------------------| + +The hardware accelerator is designed to operate in indoor environments and in temperatures ranging from -5°C to +55°C. + +## 7.4 O-RU<sub>7-2x</sub> Hardware Reference Design + +### 7.4.1 O-RU<sub>7-2x</sub> High-Level Functional Block Diagram + +Figure 7.4-1 provides a high-level functional block diagram depicting the major HW/SW components. It also highlights the internal/external interfaces that are required. + +![Figure 7.4-1 O-RU7-2x High-Level Functional Block Diagram](8aee1e2c6cd9828215a4b12958168c56_img.jpg) + +The diagram illustrates the high-level functional block architecture of the O-RU<sub>7-2x</sub>. The main processing chain consists of the O-RAN FH Processing Unit, the Digital Processing Unit, and the RF Processing Unit, connected in series. The O-RAN FH Processing Unit interfaces with external O-RAN DU<sub>7-2x</sub> and cascaded O-RU<sub>7-2x</sub> units via the O-RAN FH Interface. The Digital Processing Unit and RF Processing Unit are connected to an external antenna. A Timing Unit provides local timing to the O-RAN FH Processing Unit, Digital Processing Unit, and RF Processing Unit. The Timing Unit is connected to a Power Unit, which provides power to the Timing Unit, Digital Processing Unit, and RF Processing Unit. An optional GNSS (optional) block provides local timing from GNSS or equivalent to the Timing Unit. The entire system is enclosed in a dashed box labeled O-RU<sub>7-2x</sub>. + +Figure 7.4-1 O-RU7-2x High-Level Functional Block Diagram + +**Figure 7.4-1 O-RU<sub>7-2x</sub> High-Level Functional Block Diagram** + +### 7.4.2 O-RU<sub>7-2x</sub> Hardware Components + +#### 7.4.2.1 O-RAN Fronthaul Processing Unit + +The O-RAN Fronthaul Processing Unit receives eCPRI frames from the O-RAN fronthaul and process the control/data packets. + +#### 7.4.2.2 Digital Processing Unit + +The digital processing unit of O-RU<sub>7-2x</sub> is mainly for performing Low-PHY, DDC, DUC, CFR, DPD and synchronization. In this implementation, the ADC and DAC functions are also included in the digital processing unit. + +This solution of the digital processing unit incorporates FPGA and a processor. The FPGA handles high speed digital processing, and the processor is used for hardware device configuration and the OAM function. The FPGA and the processor core can be integrated into one SoC or implemented into two devices. Here the FPGA and the processor core are integrated into one SoC device. + +![Figure 7.4-2 Digital Processing Unit Block Diagram. The diagram shows a central FPGA block containing a Processor, ADC, and DAC. To the left, DDR, Flash, and Debug blocks are connected to the Processor via MIG, SPI, and MII interfaces respectively. To the right, the Processor is connected to a PLL block via SPI, which provides clock signals of 245.76MHz, 1.92MHz, and 156.25MHz. The Processor is also connected to an SFP+ block via an I2C interface, which provides a 10G Serdes connection. A power supply block at the bottom lists voltages: 3.3V, 2.5V, 1.8V, 1.35V, 1.2V, and 0.9V.](13c759b5b009b236d5f6322847b87f21_img.jpg) + +Figure 7.4-2 Digital Processing Unit Block Diagram. The diagram shows a central FPGA block containing a Processor, ADC, and DAC. To the left, DDR, Flash, and Debug blocks are connected to the Processor via MIG, SPI, and MII interfaces respectively. To the right, the Processor is connected to a PLL block via SPI, which provides clock signals of 245.76MHz, 1.92MHz, and 156.25MHz. The Processor is also connected to an SFP+ block via an I2C interface, which provides a 10G Serdes connection. A power supply block at the bottom lists voltages: 3.3V, 2.5V, 1.8V, 1.35V, 1.2V, and 0.9V. + +**Figure 7.4-2 Digital Processing Unit Block Diagram** + +The FPGA resource requirements are shown in Table 7.4-1. + +**Table 7.4-1 FPGA Resource Requirements** + +| | | +|--------------------|---------| +| System Logic cells | 489 K | +| CLB Flip-Flops | 447 K | +| CLB LUT | 223 K | +| Distributed RAM | 6.9 Mb | +| Block RAM | 22.8 Mb | +| UltraRAM (Mb) | 45 Mb | +| DSP Slices | 1872 | +| GTY Transceivers | 8 | + +The RF requirements of O-RU<sub>7-2x</sub> are listed in Table 7.4-2 + +**Table 7.4-2 RF Requirements** + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Condition/Comment | +|--------------------------------------------------|--------|-----|------|------|------|----------------------------------------------------------------------------| +| <b>Transmitters</b> | | | | | | | +| Centre Frequency | | 650 | | 6000 | MHz | | +| Transmitter Synthesis Bandwidth | | | | 450 | MHz | | +| Transmitter Large Signal Bandwidth | | | | 200 | MHz | | +| Transmitter Attenuator Power Control Range | | 0 | | 32 | dB | Signal to noise ratio (SNR) maintained for attenuation between 0 and 20 dB | +| Transmitter Attenuation Power Control Resolution | | | 0.05 | | dB | 20 MHz LTE/NR at -12 dBFS | + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Condition/Comment | +|----------------------------------------------------|-------------------|-----|--------|------|--------|----------------------------------------------------------------------------------------------------------------------------------| +| Adjacent Channel Leakage Ratio (ACLR) | | | -66 | | dB | 75 MHz < f ≤ 2800 MHz | +| In Band Noise Floor | | | -154.5 | | dBm/Hz | 0 dB attenuation; in band noise falls 1 dB for each dB of attenuation for attenuation between 0 dB and 20 dB | +| Out of Band Noise Floor | | | -153 | | dBm/Hz | 600 MHz < f ≤ 3000 MHz | +| Maximum Output Power | | | 6 | | dBm | 0 dB attenuation; 3 × bandwidth/2 offset | +| Third Order Output Intermodulation Intercept Point | OIP3 | | 27 | | dBm | 600 MHz < f ≤ 3000 MHz | +| Error Vector Magnitude (3GPP Test Signals) | EVM | | | | | | +| 1900 MHz LO | | | 0.6 | | % | 50 kHz RF PLL loop bandwidth | +| 3800 MHz LO | | | 0.53 | | % | 300 kHz RF PLL loop bandwidth | +| <b>Observation Receivers</b> | ORx | | | | | | +| Center Frequency | | 450 | | 6000 | MHz | | +| Gain Range | | | 30 | | dB | IIP3 improves dB for dB for the first 18 dB of gain attenuation; QEC performance optimized for 0 dB to 6 dB of attenuation only. | +| Analog Gain Step | | | 0.5 | | dB | For attenuation steps from 0 dB to 6 dB | +| Receiver Bandwidth | | | | 450 | MHz | | +| Maximum Usable Input Level | P <sub>HIGH</sub> | | -11 | | dBm | 0 dB attenuation; increases dB for dB with attenuation. | +| Integrated Noise | | | -58.7 | | dBFS | 450 MHz Integration bandwidth | +| | | | -57.5 | | dBFS | 491.52 MHz Integration bandwidth | +| Third Order Input Intermodulation Intercept Point | IIP3 | | | | | Maximum observation receiver gain; test condition: P <sub>HIGH</sub> -11 dB/tone | +| Narrow Band | | | | | | | +| 1900 MHz | | | 15 | | dBm | | +| 2600 MHz | | | 16.5 | | dBm | | +| 3800 MHz | | | 18 | | dBm | | +| Wide Band | | | | | | IM3 products > 130 MHz at baseband; test condition: P <sub>HIGH</sub> - 11 dB/tone; | + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Condition/Comment | +|------------------------------------------|-------------------|-----|-----|------|------|----------------------------------------------------------------------------------------------------------------------------------------| +| 1900 MHz | | | 13 | | dBm | 491.52 MSPS | +| 2600 MHz | | | 11 | | dBm | | +| 3800 MHz | | | 13 | | dBm | | +| Third Order Intermodulation Product | IM3 | | -70 | | dBc | 600 MHz < f ≤ 3000 MHz | +| Spurious Free Dynamic Range | SFDR | | 64 | | dB | Non IMx related spurs, does not include HDx; (P <sub>HIGH</sub> - 11) dB input signal | +| Harmonic Distortion | | | | | | (P <sub>HIGH</sub> - 11) dB input signal | +| Second Order Harmonic Distortion Product | HD2 | | -80 | | dBc | In band HD falls within ±100 MHz | +| | | | -73 | | dBc | Out of band HD falls within ±225 MHz | +| Third Order Harmonic Distortion Product | HD3 | | -70 | | dBc | In band HD falls within ±100 MHz | +| | | | -65 | | dBc | Out of band HD falls within ±225 MHz | +| <b>Receivers</b> | | | | | | | +| Center Frequency | | | | 6000 | MHz | | +| Analog Gain Step | | | 30 | | dB | Attenuator steps from 0 dB to 6 dB | +| | | | 1 | | dB | Attenuator steps from 6 dB to 30 dB | +| Receiver bandwidth | | | | 200 | MHz | | +| Maximum Usable Input Level | P <sub>HIGH</sub> | | -11 | | dBm | 0 dB attenuation; increase dB for dB with attenuation; continuous wave = 1800 MHz; corresponds to -1 dBFS at ADC 75 MHz < f ≤ 3000 MHz | +| Noise Figure | NF | | 12 | | dB | 0 dB attenuation at receiver port 600 MHz < f ≤ 3000 MHz | +| Input Third Order Intercept Point | IIP3 | | | | | | +| Difference Product | IIP3, d | | | | | Two (P <sub>HIGH</sub> - 9) dB tones near band edge | +| 2600 MHz (Wideband) | | | 17 | | dBm | | +| 2600 MHz (Midband) | | | 21 | | dBm | | +| Sum Product | IIP3, s | | | | | Two (P <sub>HIGH</sub> - 9) dB tones, at bandwidth/6 offset from the LO | +| 2600 MHz (Wideband) | | | 20 | | dBm | | + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Condition/Comment | +|-----------|--------|-----|-----|-----|------|----------------------------------------------------------------------------------------------------------| +| HD3 | HD3 | | -66 | | dBc | (P <sub>HIGH</sub> – 6) dB continuous wave tone at bandwidth/6 offset from the LO 600 MHz < f ≤ 4800 MHz | + +#### 7.4.2.3 RF Processing Unit + +##### 7.4.2.3.1 Power Amplifier (PA) Reference Design + +The Power Amplifier boosts the RF output to the level required for the base station class. + +###### 7.4.2.3.1.1 Hardware Requirements + +###### - Interface Requirements + +The interface requirements of the transmit PA are listed in Table 7.4-3 + +**Table 7.4-3 Power Amplifier Interface Requirements** + +| Item Name | Description | +|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| RF Enable | The enable input should be compatible with 1.8V logic and tolerate 3.3V as required. A logic high enables the PA. A logic low disables the device and places it in a minimum dissipation mode. | +| RF Output | RF outputs support 50-ohm single ended to properly interface to a directional coupler, isolator, switch or antenna. | +| RF Input | RF inputs should support 50-ohm, single ended match to the transceiver output or preamp. | + +###### - Power Requirements + +RF output power required is nominally 5 W (37 dBm). DC power is driven by efficiency of the PA and should not be more than 17W and the efficiency should be greater than 30%. + +###### - RF Requirements + +The PA and driver should have enough gain to boost the transceiver output to the rated power level. The output power should be at least 5W (37 dBm) including the loss of the circulator and antenna filter. The ACLR with DPD and CFR should be better than 47dBc according to the related 3GPP test models. + +**Table 7.4-4 Power Amplifier RF Requirements** + +| Item Name | n 78 | +|--------------------|-------------------------| +| Gain | >60 dB including driver | +| P3dB | 47 dBm | +| Input Return Loss | <-15 dB | +| Output Return Loss | <-15 dB | +| Switching Speed | <1uS | +| HD2 | >28 dBc | +| HD3 | >30 dBc | + +###### 7.4.2.3.1.2 Hardware Design + +RFin is the input of the PA, RFout is the output of the PA. Vdd and Vbias are the power input of the PA. RFen is the control pin to disable or enable the PA. The input and output should be matched to 50 ohms to optimize return loss as much as possible. Proper decoupling shall be provided to minimize impact of supply ripple on the RF output. + +![Figure 7.4-3 Power Amplifier Reference Design. A schematic diagram of a power amplifier. It features a central triangular amplifier symbol. The input is labeled 'RFin' and the output is labeled 'RFout'. The amplifier is powered by 'Vdd' and 'Vbias' (connected to the bottom of the triangle). A feedback path labeled 'RFen' is connected from the output back to the input.](a075681cfa5575e1f27913b2037accd2_img.jpg) + +Figure 7.4-3 Power Amplifier Reference Design. A schematic diagram of a power amplifier. It features a central triangular amplifier symbol. The input is labeled 'RFin' and the output is labeled 'RFout'. The amplifier is powered by 'Vdd' and 'Vbias' (connected to the bottom of the triangle). A feedback path labeled 'RFen' is connected from the output back to the input. + +**Figure 7.4-3 Power Amplifier Reference Design** + +##### 7.4.2.3.2 Low Noise Amplifier (LNA) Reference Design + +###### 7.4.2.3.2.1 Hardware Requirements + +###### - Interface Requirements + +The interface requirements of the transmit LNA are listed in Table 7.4-5. + +**Table 7.4-5 LNA Interfaces Requirements** + +| Item Name | Description | +|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Enable | The enable input should be compatible with 1.8V logic and tolerate 3.3V as required. A logic high enables the LNA. A logic low disables the device and places it in a minimum dissipation mode. | +| LNA Bypass | The LNA Bypass skips the second stage LNA effectively reducing the overall gain. This would be selected when the input signal compromises the linearity of the amplifier. | +| RF Out | RF outputs support 50-ohm single ended to properly interface to the RF filtering and Rx input port of transceiver. | +| TR Switch | The TR switch is used to shunt any reflected RF power that reaches the LNA to a shunt load during the transmit period. | +| RF Input | RF inputs should support 50-ohm, single ended match to circulator. | +| Termination | This RF output port shunts any reflected transmit power to an appropriate load during the Transmit period to protect the input of the LNA. | + +###### - Power Requirements + +DC power per channel should not exceed 0.5W. + +###### - RF Performance Requirements + +Table 7.4-6 LNA RF Requirements + +| Item Name | n 78 | +|------------------|------------| +| Gain (High/Low) | 34/17 dB | +| NF (High/Low) | 1.6/1.6 dB | +| OIP3 (High/Low) | 34/34 dBm | +| OP1dB (High/Low) | 19/15 dBm | +| TR Switch Time | <1uS | + +###### 7.4.2.3.2.2 Hardware Design + +Figure 7.4-4 shows the configuration for a dual-stage LNA. The RF inputs and outputs should be properly matched to optimize the noise performance and flatness of the amplifier. The input switch is used to forward any reflected transmit energy to an external load during the transmit period to protect the LNA from damage. The DC supply voltage, VCC, should be properly filtered to prevent power supply noise from entering the LNA and reducing performance. + +![Figure 7.4-4 LNA Reference Design block diagram. The diagram shows a dual-stage LNA circuit. An input switch selects between RF_in and Termination_ext. The selected signal enters the first LNA stage, which is controlled by LNA_AEN. The output of the first stage goes to the input of the second LNA stage, which is controlled by LNA_bypass. The output of the second stage is RF_out. A VCC supply is connected to both stages. A TR (Transmit) signal is connected to the input switch to enable protection during transmit periods.](932a391ae44425db645e8305c3e18868_img.jpg) + +Figure 7.4-4 LNA Reference Design block diagram. The diagram shows a dual-stage LNA circuit. An input switch selects between RF\_in and Termination\_ext. The selected signal enters the first LNA stage, which is controlled by LNA\_AEN. The output of the first stage goes to the input of the second LNA stage, which is controlled by LNA\_bypass. The output of the second stage is RF\_out. A VCC supply is connected to both stages. A TR (Transmit) signal is connected to the input switch to enable protection during transmit periods. + +Figure 7.4-4 LNA Reference Design + +##### 7.4.2.3.3 Circulator Reference Design + +For TDD use, the Tx and Rx links work in time duplex. To properly couple the Tx energy to the antenna and the Rx signal to the LNA input, a circulator is used to perform this function given the potentially high RF power being processed through this device. The circulator can be configured as a clockwise or counterclockwise device depending on the layout details. + +###### 7.4.2.3.3.1 Hardware Requirements + +###### ● Interface Requirements + +The circulator includes 3 ports that can function as in input or an output. If the device is labelled clockwise, then for each input, its nominal output is the next pin rotating right around the device. If it is counterclockwise, the nominal output is the next pin rotating to the left around the device. + +###### ● RF Requirements + +**Table 7.4-7 Circulator RF Requirements** + +| Item Name | n 78 | +|----------------|--------------| +| Rotation | CW or CCW | +| Average Power | Up to 43 dBm | +| Peak Power | 50 dBm | +| Impedance | 50 ohms | +| Insertion Loss | -0.3 dB | +| Isolation | 20 dB | +| Return Loss | 22 dB | + +###### 7.4.2.3.3.2 Hardware Design + +The example on the left in Figure 7.4-5 is a clockwise oriented device. The RF input enters pin 1 and exits pin 2. Pin 2 can also be used as an input and its output is pin 3. Finally pin 3 can also function as an input with pin 1 being the output. The device on the right is counterclockwise oriented and the signal flow is the in the opposite direction. + +![Figure 7.4-5 shows two circular diagrams representing circulator reference designs. The left diagram shows a clockwise signal flow: input at pin 1, output at pin 2, and output at pin 3. The right diagram shows a counterclockwise signal flow: input at pin 1, output at pin 3, and output at pin 2.](94bc0bb472bf4f6dbdc3f37f3d4fd0a2_img.jpg) + +Figure 7.4-5 shows two circular diagrams representing circulator reference designs. The left diagram shows a clockwise signal flow: input at pin 1, output at pin 2, and output at pin 3. The right diagram shows a counterclockwise signal flow: input at pin 1, output at pin 3, and output at pin 2. + +**Figure 7.4-5 Circulator Reference Design** + +### 7.4.3 Synchronization and Timing + +The purpose of the clocking device is to accept the network reference clock, typically 1 pps, and generate a jitter free reference clock(s) for other devices in the system. The clock is typically part of an IEEE 1588 implementation either controlled by an external stack or implemented in the clock device itself which could be part of the baseband implementation. + +#### 7.4.3.1 Hardware Requirements + +##### ● Interface Requirements + +The interface requirements of the transmit clocking are listed in Table 7.4-8. + +**Table 7.4-8 Interface requirements of the clocking** + +| Item Name | Description | +|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Clock Input | The clock device should receive a network reference clock from the FPGA/ASIC. This typically could be a 1pps, 10 MHz or other standard reference as determined by the specific implementation. More than one input is allowed that may be selected between when the reliability of one reference is compromised. Standard differential clocking should be used to preserve signal integrity. | +| Control | Control of the transceiver is by way of 3 or 4 wire SPI or IIC functioning as a slave. Support for 1.8V control is required and tolerance of 3.3V is preferred. Typically, the clock devices will be part of an IEEE1588v2 protocol loop controlled by way of this control interface or other GPIO lines as required by the hardware implementation. | +| Clock Outputs | One or more clock outputs are required to drive the digital device and transceiver clock | + +| | | +|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | inputs. Each output should be independently programmable in frequency to suit the application. The outputs should nominally be differential to preserve clocking edge and to maximize tolerance of high common mode signals. | +| RF Inputs | RF inputs should support 50 ohm or 100 ohms, single ended or differential signalling to match the transceiver output. | + +##### - Power Dissipation + +Total dissipation should be about less than 2W. + +##### - RF Requirements + +Clocking RF requirements are given in the following table. + +**Table 7.4-9 Clocking RF requirements** + +| Absolution Phase Noise, Dual Loop Mode - LVDS OUTPUT | Typical | Additional Information | +|------------------------------------------------------|-------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| $f_{OUT} = 122.88 \text{ MHz}$ | | Example is using an external 122.88 MHz VCXO (Crystek CVHD-950); reference = 122.88 MHz; channel divider = 10 or 1; PLL2 loop bandwidth (LBW) = 450 kHz. | +| 10 Hz Offset | -86 dBc/Hz | | +| 100 Hz Offset | -106 dBc/Hz | | +| 1 kHz Offset | -126 dBc/Hz | | +| 10 kHz Offset | -135 dBc/Hz | | +| 100 kHz Offset | -139 dBc/Hz | | +| 800 kHz Offset | -147 dBc/Hz | | +| 1 MHz Offset | -148 dBc/Hz | | +| 10 MHz Offset | -157 dBc/Hz | | +| 40 MHz Offset | -158 dBc/Hz | | +| Absolute Phase Noise, Single Loop Mode – LVDS OUTPUT | Typical | | +| LVDS OUTPUT | | | +| $f_{OUT} = 122.88 \text{ MHz}$ | | Example is using an external 122.88 MHz reference (SMA100A generator); reference = 122.88 MHz; channel divider = 10; PLL2 LBW = 450 kHz. | +| 10 Hz Offset | -111 dBc/Hz | | +| 100 Hz Offset | -113 dBc/Hz | | +| 1 kHz Offset | -123 dBc/Hz | | +| 10 kHz Offset | -135 dBc/Hz | | +| 100 kHz Offset | -140 dBc/Hz | | + +| | | | +|-------------------------------------------------|-------------|------------------------------------------------------------------------------------------------------------------------------| +| 800 kHz Offset | -147 dBc/Hz | | +| 1 MHz Offset | -148 dBc/Hz | | +| 10 MHz Offset | -157 dBc/Hz | | +| 40 MHz Offset | -157 dBc/Hz | | +| CLOCK OUTPUT ADDITIVE TIME JITTER (BUFFER MODE) | Typical | Example is using an external 122.88 MHz source driving VCXO inputs (distribution section only, does not include PLL and VCO) | +| $f_{OUT} = 122.88$ MHz | 79 fS | Integrated BW = 200 kHz to 5 MHz | +| | 101 fS | Integrated BW = 200 kHz to 10 MHz | +| | 140 fS | Integrated BW = 12 kHz to 20 MHz | +| | 187 fS | Integrated BW = 10 kHz to 40 MHz | +| | 189 fS | Integrated BW = 1 kHz to 40 MHz | +| | 176 fS | Integrated BW = 1 MHz to 40 MHz | + +#### 7.4.3.2 Hardware Design + +For the clocking function, it is usually performed by a synchronization IC which may include one or more PLLs. It also can supply numbers of output port to support different frequency clocking. + +![Figure 7.4-6 PLL Reference Design Diagram. This block diagram illustrates the internal architecture of a PLL reference design. On the left, external inputs include differential clock signals CLK0 and CLK1, and GPIO pins GPIO[0] and GPIO[3]. These connect to a central 'Reference Monitors' and 'Reference Switching State Machines' block. A 'System DPLL' block is connected to the top left, with a 'FOD' (Frequency Offset Detector) block. A 'Combo Bus' connects the System DPLL to the Reference Monitors. On the top right, 'OSCI' and 'OSCO' pins connect to an 'Osc System APLL' block, which also has a 'FOD' block. The Reference Monitors block outputs to several 'DPLL / DCO' blocks (labeled DCO_0, DCO_2, DCO_5, DCO_7), each with its own 'FOD' block. These DPLL blocks output to a series of 'Div' (divider) blocks, which then output to a series of 'Out' pins labeled Q0 through Q11. At the bottom, there are control and status blocks: 'I2C Master', 'SPI/I2C Aux', 'Status and Configuration Registers', 'OTP', and 'GPIO / JTAG'.](b33888f97874a82cfb4743e3fb7ff477_img.jpg) + +Figure 7.4-6 PLL Reference Design Diagram. This block diagram illustrates the internal architecture of a PLL reference design. On the left, external inputs include differential clock signals CLK0 and CLK1, and GPIO pins GPIO[0] and GPIO[3]. These connect to a central 'Reference Monitors' and 'Reference Switching State Machines' block. A 'System DPLL' block is connected to the top left, with a 'FOD' (Frequency Offset Detector) block. A 'Combo Bus' connects the System DPLL to the Reference Monitors. On the top right, 'OSCI' and 'OSCO' pins connect to an 'Osc System APLL' block, which also has a 'FOD' block. The Reference Monitors block outputs to several 'DPLL / DCO' blocks (labeled DCO\_0, DCO\_2, DCO\_5, DCO\_7), each with its own 'FOD' block. These DPLL blocks output to a series of 'Div' (divider) blocks, which then output to a series of 'Out' pins labeled Q0 through Q11. At the bottom, there are control and status blocks: 'I2C Master', 'SPI/I2C Aux', 'Status and Configuration Registers', 'OTP', and 'GPIO / JTAG'. + +**Figure 7.4-6 PLL Reference Design Diagram** + +CLK0 and CLK1 are differential reference clock inputs from the source to be cleaned up and used as the system reference. OSCI/OSCO should be connected to a crystal, and it also accepts a reference from a clock oscillator or a + +fundamental mode parallel-resonant crystal. XO\_DPLL is single-ended signal from the external TCXO. RESET(bar) is an active low pin to reset the internal logic to their default states. CS(bar) is an active low chip select for serial control. SCLK/SCL is a serial control port clock for both SPI and I2C. SDIO/SDA is a bidirectional serial data pin for both SPI and I2C. SDO is the serial data out pin for 4-wire mode. Q0 through Q11 are differential programmable output clock signals. These are the primary outputs of this device and provide high performance clock signals to the transceiver, baseband device and other key elements. This device is also responsible for providing SYSREF to various devices in the system if required. It may also use an external SYSREF as a source that may be retimed for local timing if necessary. GPIO0~9 are GPIO signals. The GPIO signals are intended to provide a user with a flexible method to manage the control and status of the part via pins without providing dedicated pins for each possible function that may be wasted in a lot of applications. The GPIOs are fully configurable so that any GPIO can perform any function on any target logic block. + +### 7.4.4 External Interface Ports + +The following table shows the external ports or slots provided by the O-RU<sub>7-2x</sub>. External connections can be aggregated into a composite connector to minimize the points of environmental ingress as required for a specific deployment. + +**Table 7.4-10 External Port List** + +| Port Name | Feature Description | +|---------------------|-------------------------------------------------------------------| +| Fronthaul interface | One 25Gbps optical interface to connect with O-DU <sub>7-2x</sub> | +| | One 25Gbps optical interface for cascade | +| Debug interface | RJ45 for debug usage | +| Power interface | Two-pin male plug for power cable | + +### 7.4.5 Mechanical + +One such mechanical structure is shown in Figure 7.4-7. The shell should provide appropriate environmental protection, RF shielding and passive thermal dissipation. Internally, thermal pads are used to contact local heat sources and transfer that heat to the frame which in turn dissipates the heat through bulk metal and fins used to increase the effective surface area. Other enclosures are possible. + +![Figure 7.4-7 Mechanical Enclosure Diagram: A 3D perspective drawing of a rectangular metal enclosure. The dimensions are labeled: the front face width is 280, the depth is 432, and the height is 118. The top edge length is labeled 467(connector). The enclosure features a handle on the right side and a series of connectors along the front edge.](c11f2148aa10accdfd2f411b5dc51091_img.jpg) + +Figure 7.4-7 Mechanical Enclosure Diagram: A 3D perspective drawing of a rectangular metal enclosure. The dimensions are labeled: the front face width is 280, the depth is 432, and the height is 118. The top edge length is labeled 467(connector). The enclosure features a handle on the right side and a series of connectors along the front edge. + +**Figure 7.4-7 Mechanical Enclosure Diagram** + +### 7.4.6 Power Unit + +For the power solution of the O-RU<sub>7-2x</sub> can be over power cable. And for the board power solution, LDO and DC-DC can be used. + +#### 7.4.6.1 Hardware Requirements + +The power unit is responsible for isolating and converting the telco supply to appropriate voltages for distribution to individual supply domains in the O-RU<sub>7-2x</sub>. The typical dissipation is outlined below. The RF front end is broken out separately since different deployment scenarios will require different frequencies and power levels resulting in significantly different total dissipation. Total Power is the sum of the two sections below. + +**Table 7.4-11 Digital Processing Unit Power Requirements** + +| Module | 8T8R(W) | Notes | +|----------------------------------------------------------------|---------|--------------------------------| +| FPGA | 40 | | +| PLL | 1.5 | | +| Ethernet PHY | 1 | | +| DDR | 1 | | +| SFP+ Module | 1.5 | 1 module installed | +| Others | 3 | | +| Total device consumption | 48 | | +| O-RU <sub>7-2x</sub> digital processing unit power consumption | 56.5 | on board power efficiency 0.85 | + +**Table 7.4-12 RF Processing Unit Power Requirements** + +| Module | 8T8R(W) | Notes | +|-----------------------------------------------------------|---------|-------------------------------------| +| PA | 150 | 75% Tx,Max RF. 5W rms output@100MHz | +| PA Drive Amp | 12 | | +| LNA | 5 | 28% Rx | +| Others | 3 | Bias generators and controller | +| Total device consumption | 170 | | +| O-RU <sub>7-2x</sub> RF processing unit power consumption | 200 | on board power efficiency 0.85 | + +#### 7.4.6.2 Hardware Design + +The block diagram of the power unit is shown in Figure 7.4-8, which depict the power distribution to various functional modules such as PA board and FPGA/RF SoC board(Digital) along with approximate power requirements. + +![Figure 7.4-8 Power Unit Design block diagram showing the power flow from Telco Supply (-48V) through protection and isolation modules to various local supply generators for different boards.](c1c72413b3adade28073deb355cd224b_img.jpg) + +``` + +graph LR + Telco[Telco Supply (-48V)] --> PM[Over Voltage Protection Module, Over Current Protection Module, Reverse polarity Module, and EMI Filter] + PM -- 48V --> IM1[Isolated Module] + IM1 -- 28V --> IM2[Isolated Module] + IM2 -- 5V --> LSG1[Local Supply Generators DC-DC&LDO/Buck converter for FPGA and RF/Digital Board] + IM1 -- 5V --> LSG2[Local Supply Generators DC-DC&LDO/Buck converter for PA/PA Board] + IM1 -- 28V --> LSG2 + LSG1 --> Out1[3.3V/1.8V/1.0V ...] + LSG2 --> Out2[3.3V/1.8V ...] + +``` + +Figure 7.4-8 Power Unit Design block diagram showing the power flow from Telco Supply (-48V) through protection and isolation modules to various local supply generators for different boards. + +Figure 7.4-8 Power Unit Design + +### 7.4.7 Thermal + +The O-RU<sub>7-2x</sub> will use passive cooling. + +### 7.4.8 Environmental and Regulations + +The O-RU<sub>7-2x</sub> hardware system is RoHS Compliant. + +Table 7.4-13 Environmental Features + +| Item Name | Description | +|-----------------------|-----------------| +| Operating Temperature | -40°C to +55°C | +| Storage Temperature | -45°C to +70°C | +| Humidity | 2% to 95% | +| Atmospheric Pressure | 70kPa to 106kPa | + +# --- History + +| Date | Revision | Description | +|------------|----------|----------------------------------| +| 2022.11.08 | 01.00.00 | Published as final version 01.00 | \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/054b3c58df5f13334b3a14016c7f903a_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/054b3c58df5f13334b3a14016c7f903a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ebe108017c2f26349431898494d7c6ec4953c9a8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/054b3c58df5f13334b3a14016c7f903a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:60cb99678b99d2ecd041b3227389fdf21c75b861920750f6253bb155c6cf2545 +size 4554 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/2d5da092c79e6796ecc043aa42b2ce00_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/2d5da092c79e6796ecc043aa42b2ce00_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..818d0a3b083ca6fad5b5ab9bd2589756bb1b7c28 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/2d5da092c79e6796ecc043aa42b2ce00_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9a721b09c3dfe84a02e4f1c38a9801931271f07ef485a69a155cba62593dfd7 +size 61579 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/343611df4fcd20294b88d83667a75bdf_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/343611df4fcd20294b88d83667a75bdf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9666e841ea4791342b4dcc6a6b77afba3a4e5da4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/343611df4fcd20294b88d83667a75bdf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3e395006b468f11e025ff67e6ee313007500d298d24d736bb27dbf58d2113464 +size 26256 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/390534bd29d40567782170b486631969_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/390534bd29d40567782170b486631969_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f9844c448949205bf2e69817b1ec82532ac9c8b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/390534bd29d40567782170b486631969_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f3329c6bcdd1c3614c669dbb3896c52671fb4837cb4945875f22926b9d8f6638 +size 4498 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/46ea392b6ae2bd95b05986469e4e0c9f_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/46ea392b6ae2bd95b05986469e4e0c9f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..22d1c0286074dd280be2a94e1e858a1a1d92a66d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/46ea392b6ae2bd95b05986469e4e0c9f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7075a6fda82e6c60b6d69d7a37964072e49adcbba35ba0c772d88a75a0862200 +size 4535 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/524deb0abd39afd6173b82156e88a85e_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/524deb0abd39afd6173b82156e88a85e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a190eaacb67df1269fc9fe9aa2eb49a8c5a73bfe --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/524deb0abd39afd6173b82156e88a85e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b3010477b79bfa9d4bbc664464347494331eadaad868ead7f0f5f7b5b14ae53 +size 32476 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/65aa1ef346b00831174a2929ec75b255_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/65aa1ef346b00831174a2929ec75b255_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..23c555838e64f9422fd59a4387a026f1100a5ee0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/65aa1ef346b00831174a2929ec75b255_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ed5bf314e7eae66fb9597ff161823ba75e318c029e5c59379b79895acb55a9d +size 4517 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/66326bdd506c866d9a0920e9c5d797e6_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/66326bdd506c866d9a0920e9c5d797e6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4844a26f3c12acd75740113487678d92c8d31f00 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/66326bdd506c866d9a0920e9c5d797e6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9b689a8e7dadfa546f247908f444a18cc994ede87555bc837f284cd84c043049 +size 62844 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/66a196b102cfa670952d0dde4c3ccd6b_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/66a196b102cfa670952d0dde4c3ccd6b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4721c8f0eb30a651c795a9e32a1f517917d6d23c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/66a196b102cfa670952d0dde4c3ccd6b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ab42d7cae1e8c7482ad67ecdcd96a47338a2f48c3f490a2b019e7679d2175c6 +size 6303 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/74f371f8cb4295a373273cce381daf2a_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/74f371f8cb4295a373273cce381daf2a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1874c23da4f76b47458fe3268ce714c922d5a56b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/74f371f8cb4295a373273cce381daf2a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ec2d8da7f54130aba36a4fd1a32194fee867d7c8a164bb682b0b83eb531900e2 +size 24565 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/9127ca154aa701f3acf042b3830e9f40_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/9127ca154aa701f3acf042b3830e9f40_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bc86f5701ffb2249a20683fa17440ed548369072 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/9127ca154aa701f3acf042b3830e9f40_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6035d9851c1c61e824c3e5129554ec1553b34b9fe7b414807f722bf9dd9aa0f4 +size 18171 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/960998b29702d84d1604164abdc6c72d_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/960998b29702d84d1604164abdc6c72d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..11db21693ce1af03c446ebb3f35538f7346de6ae --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/960998b29702d84d1604164abdc6c72d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:877f6932ca18d94d00fc29d334f919f19428f043ddf5223e853b4c6a0d0f9125 +size 4543 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/99908d6b5a589d69819a4de83c3e0105_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/99908d6b5a589d69819a4de83c3e0105_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f307db087ea666796d92a39999933819b185c7e2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/99908d6b5a589d69819a4de83c3e0105_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:747fd393c56a2d91badf5cb0b436d8385af0c8c337011f436b1e5737fca426e9 +size 17041 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/9bf681a2babc07b4a996bc57f05adca2_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/9bf681a2babc07b4a996bc57f05adca2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db3bdd9269f8446eac8be746a2dcad290abfb0e4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/9bf681a2babc07b4a996bc57f05adca2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:47f66b00678282f06644f835c77b141bf9d62d5820e9b38a6abe340bb25fd2b5 +size 67308 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/a416367a20358b4e83fff769d83c8e7c_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/a416367a20358b4e83fff769d83c8e7c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1e5a7e121b6e973a57c9c1d4dec20899003fddef --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/a416367a20358b4e83fff769d83c8e7c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:939b695c67cac4758fc7bbcddd7d66bf1ab73ac4cb81d67cf8b48d2b35dce77c +size 4431 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/aaeb27559097506a79108d8f75b07b39_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/aaeb27559097506a79108d8f75b07b39_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..65f4bdef6e6208a866c2ca159d43efaa4f6e6827 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/aaeb27559097506a79108d8f75b07b39_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab396adefba746d4cf13c1e4735c121769924814120dfded10a9e5177b79e191 +size 4538 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/b0b88b7bbc3aac4b0de5666690761f98_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/b0b88b7bbc3aac4b0de5666690761f98_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cb615b9fe5c36a8c5fb499609745124963c6ee33 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/b0b88b7bbc3aac4b0de5666690761f98_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7aad727c0501de7e3055f65f0b049aa9a3fa5c6f5a32f7e1b940455f43a465cb +size 35672 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/b11f52de8b482309b3ca21214097319d_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/b11f52de8b482309b3ca21214097319d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..935df6d597bd9421825cd33ee6c4a5d48e74bd2f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/b11f52de8b482309b3ca21214097319d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5829ed7514292693613dda56fd5151c667c5e265255a8884f2868b343f10802f +size 33483 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/b403c896d250245e768c3bcec7aaef2f_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/b403c896d250245e768c3bcec7aaef2f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3a904a5833e88c2efba0ad359feb85827959f6e5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/b403c896d250245e768c3bcec7aaef2f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:535dc36b501790123ac0918b1e75e661ee4407346322190bdb2e2daaaca87eee +size 38411 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/bc3d7c1b78e13de258420c36406fb1fb_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/bc3d7c1b78e13de258420c36406fb1fb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3f62ef0e82e56562cbc2a942d823c69dd860b148 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/bc3d7c1b78e13de258420c36406fb1fb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:62d61518d0ddb909f61fcc60df98b46ff3a2561224ffdf7bbf9b799f7eb63fbc +size 64509 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/da8832a85ed0ebfdc8a9cd71271a089c_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/da8832a85ed0ebfdc8a9cd71271a089c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..36aee08bc9578356e2d3322759832316f1117087 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/da8832a85ed0ebfdc8a9cd71271a089c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e557d51f8e06f1a60f12aff5db195cb9045d333e2c0243960cb915f24700e66e +size 4494 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/e10258aabb03161bf61f6ee998e17607_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/e10258aabb03161bf61f6ee998e17607_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f872f7da607aa4768ba660f303a209d4efd56893 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/e10258aabb03161bf61f6ee998e17607_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8a67e6a843e5c59118193eb4b3451231c6b9139c52814c1bc1d6d29eed6e308 +size 4544 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/ee9eb0bd29ac99e96086d5b26c66b3e3_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/ee9eb0bd29ac99e96086d5b26c66b3e3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ad40be1c4d1a3fc24049699706c2589b8406adf0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/ee9eb0bd29ac99e96086d5b26c66b3e3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4fb52cbe0e10050bb6d5c37062b5391e11ff6901bdf8d4ee3c9ea93894272b3f +size 69044 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/f53a63e67722f2773ec44512a5fedbc0_img.jpg b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/f53a63e67722f2773ec44512a5fedbc0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f0dc4dca5aa27bb56492453926399d2516f86c46 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/f53a63e67722f2773ec44512a5fedbc0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4faf5d09d03a929f5aeae8c3e4edb935601cf4223e95203c0243a938936e087b +size 63821 diff --git a/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/raw.md b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..7d877bc5cd7ac85a9a25628d37c14764a3f93a24 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00/raw.md @@ -0,0 +1,915 @@ + + +# **O-RAN White Box Hardware Working Group Hardware Reference Design Specification for Fronthaul Gateway** + +--- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN White Box Hardware Working Group Hardware Reference Design Specification for Fronthaul Gateway** --- + +Copyright © 2021 by O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in the Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. + +Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238 + +VAT ID DE321720189 + +1 + +# --- Revision History + +| Date | Revision | Author | Description | +|------------|----------|--------|-------------------------------| +| 2021.07.20 | 02.00 | WG7 | Final version for publication | +| 2021.02.16 | 01.00 | WG7 | Final version for publication | + +2 + +# Contents + +| | | | | +|----|------------------------|-------------------------------------------------------------------------|----| +| 1 | | | | +| 2 | Revision History ..... | | 2 | +| 3 | Chapter 1 | Introductory Material ..... | 6 | +| 4 | 1.1 | Scope ..... | 6 | +| 5 | 1.2 | References ..... | 6 | +| 6 | 1.3 | Definitions and Abbreviations ..... | 7 | +| 7 | 1.3.1 | Definitions..... | 7 | +| 8 | 1.3.2 | Abbreviations ..... | 7 | +| 9 | Chapter 2 | Deployment Scenarios ..... | 9 | +| 10 | 2.1.1 | Deployment Scenario -1 ..... | 9 | +| 11 | 2.1.2 | Low PHY ..... | 11 | +| 12 | 2.1.3 | Timing..... | 11 | +| 13 | 2.1.4 | Attributes of FHGW <sub>7-2→8</sub> ..... | 12 | +| 14 | Chapter 3 | Hardware Architecture and Requirements ..... | 13 | +| 15 | 3.1 | FHGW <sub>7-2→8</sub> Hardware Architecture ..... | 13 | +| 16 | 3.1.1 | FHGW <sub>7-2→8</sub> Hardware Architecture Diagram ..... | 13 | +| 17 | 3.1.2 | FHGW <sub>7-2→8</sub> Functional Module Description ..... | 14 | +| 18 | 3.1.3 | FHGW <sub>7-2→8</sub> Interfaces ..... | 15 | +| 19 | 3.2 | Disaggregation and Modularity Requirements ..... | 15 | +| 20 | 3.2.1 | Internal Interfaces..... | 16 | +| 21 | 3.3 | FHGW <sub>7-2→8</sub> Hardware/Performance Requirements ..... | 17 | +| 22 | 3.3.1 | FHGW <sub>7-2→8</sub> Interface Requirements..... | 17 | +| 23 | 3.3.2 | FHGW <sub>7-2→8</sub> : Mechanical, Thermal and Power Requirements..... | 18 | +| 24 | 3.4 | Timing Requirements ..... | 18 | +| 25 | 3.5 | Security Requirements..... | 18 | +| 26 | Chapter 4 | Hardware Reference Design ..... | 20 | +| 27 | 4.1 | FHGW <sub>7-2→8</sub> Hardware Reference Design ..... | 20 | +| 28 | 4.2 | FHGW <sub>7-2→8</sub> High Level Functional Block Diagram ..... | 20 | +| 29 | 4.3 | FHGW <sub>7-2→8</sub> Hardware Components..... | 21 | +| 30 | 4.3.1 | CPU..... | 21 | +| 31 | 4.3.2 | Memory and Storage for CPU..... | 21 | +| 32 | 4.3.3 | Network Processing Unit (NPU)..... | 21 | +| 33 | 4.3.4 | Radio Signal Processor - FPGA ..... | 22 | +| 34 | 4.4 | Interfaces on Radio Signal Processor ..... | 26 | +| 35 | 4.4.1 | Interface towards the NPU ..... | 26 | +| 36 | 4.4.2 | Timing and Synchronization ..... | 27 | +| 37 | 4.4.3 | Security ..... | 27 | +| 38 | 4.4.4 | PCIe Interface ..... | 28 | +| 39 | 4.4.5 | Example Pinout of a Radio Signal Processor FPGA..... | 28 | +| 40 | 4.5 | Scalability and flexibility of Radio Signal Processor ..... | 29 | +| 41 | 4.6 | External Interface Ports on the FHGW <sub>7-2→8</sub> ..... | 29 | + +| | | | +|----|--------------------------------------------------------|----| +| 1 | Annex 1: Reference to Open CPRI specification ..... | 31 | +| 2 | Annex ZZZ : O-RAN Adopter License Agreement ..... | 31 | +| 3 | Section 1: DEFINITIONS ..... | 31 | +| 4 | Section 2: COPYRIGHT LICENSE ..... | 32 | +| 5 | Section 3: FRAND LICENSE ..... | 32 | +| 6 | Section 4: TERM AND TERMINATION ..... | 33 | +| 7 | Section 5: CONFIDENTIALITY ..... | 33 | +| 8 | Section 6: INDEMNIFICATION ..... | 33 | +| 9 | Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 33 | +| 10 | Section 8: ASSIGNMENT ..... | 34 | +| 11 | Section 9: THIRD-PARTY BENEFICIARY RIGHTS ..... | 34 | +| 12 | Section 10: BINDING ON AFFILIATES ..... | 34 | +| 13 | Section 11: GENERAL ..... | 34 | + +## Tables + +| | | | +|----|---------------------------------------------------------------------------------------|----| +| 16 | Table 1: Attributes of FHGW <sub>7-2→8</sub> ..... | 12 | +| 17 | Table 2: FHGW <sub>7-2→8</sub> Performance Requirements..... | 17 | +| 18 | Table 3: FHGW <sub>7-2→8</sub> Interface Requirements ..... | 17 | +| 19 | Table 4: FHGW <sub>7-2→8</sub> : Mechanical, Thermal and Power Requirements..... | 18 | +| 20 | Table 5: CPU Features ..... | 21 | +| 21 | Table 6: Memory and Storage Requirements ..... | 21 | +| 22 | Table 7: NPU Features..... | 22 | +| 23 | Table 8: Estimated FPGA Resource Allocation for the Designated Functions - 1..... | 23 | +| 24 | Table 9: CPRI Rate Options and the Number of Supported LTE 20MHz Carriers (AxC) ..... | 24 | +| 25 | Table 10: Estimated FPGA Resource Allocation for the Designated Functions - 2..... | 25 | +| 26 | Table 11: Example Pinout of the FPGA ..... | 28 | +| 27 | Table 12: External Legacy Port List ..... | 30 | +| 28 | Table 13: External Ethernet Port List ..... | 30 | + +## Figures + +| | | | +|----|------------------------------------------------------------------------------|----| +| 31 | Figure 1: Base Station with Split Architecture ..... | 9 | +| 32 | Figure 2: Deployment of O-DU and RU using FHGW ..... | 10 | +| 33 | Figure 3: Point to point topology for Fronthaul Gateway..... | 10 | +| 34 | Figure 4: Ring topology for Fronthaul Gateway..... | 11 | +| 35 | Figure 5: Fronthaul Gateway Hardware Architecture Diagram ..... | 13 | +| 36 | Figure 6: Fronthaul Gateway Architecture with Internal Open interfaces ..... | 16 | +| 37 | Figure 7: FHGW <sub>7-2→8</sub> Interface requirements ..... | 18 | +| 38 | Figure 8: High-level Functional Block Diagram of the FHGW ..... | 20 | +| 39 | Figure 9: Radio Signal Processing Block Diagram – FPGA Model-1 ..... | 22 | +| 40 | Figure 10: Radio Signal Processing Block Diagram – FPGA Model-2 ..... | 25 | +| 41 | Figure 11: Internal Ethernet Links between NPU and FPGA..... | 27 | +| 42 | Figure 12: Timing Circuitry ..... | 27 | + +| | | | +|---|-----------------------------------------|----| +| 1 | Figure 13: PCIe Interface to FPGA ..... | 28 | +| 2 | Figure 14: Multi-FPGA Architecture..... | 29 | +| 3 | | | + +# Chapter 1 Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG7 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e., technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. This variable is for internal WG7 use only. + +The present document specifies a hardware reference design for the fronthaul gateway. The fronthaul gateway can be used to terminate O-RAN fronthaul user, control, synchronization, and management planes for option 7-2x and to translate the signals to and from a number of CPRI interfaces (option 8). It can further multiplex or demultiplex option 7-2x fronthaul signals to or from a number of O-RUs. This version of the specification only supports option 7-2x to option 8 conversion and vice versa in addition to the transport of other traffic streams. + +In the main body of this specification (in any “chapter”) the information contained therein is informative, unless explicitly described as normative. Information contained in an “Annex” to this specification is always informative unless otherwise marked as normative. + +## 1.2 References + +- [1] ORAN-WG7.DSC.0-V02.00 Technical Specification, ‘Deployment Scenarios and Base Station Classes for White Box Hardware’. +- [2] ORAN-WG4.CUS.0-v04.00 Technical Specification, ‘O-RAN Fronthaul Working Group Control, User and Synchronization Plane Specification’. +- [3] O-RAN Architecture Description, O-RAN-WG1-O-RAN Architecture Description - v01.00.00 +- [4] CPRI interface specification V 7.0. <http://cpri.info/spec.html> +- [5] O-RAN Hardware Reference Design Specification for Indoor Picocell FR1 with Split Architecture Option 8 v1.0 + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in [2] and the following apply. + +An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, as in [2]. + +| | | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 7-2 | Fronthaul interface split option as defined by O-RAN WG4, also referred to as 7-2x | +| 5G | Fifth-Generation Mobile Communications | +| ASIC | Application Specific Integrated Circuit | +| BS | Base Station | +| CU | Centralized Unit as defined by 3GPP | +| DL | Downlink | +| DPLL | Digital Phase Lock Loop | +| DSP | Digital Signal Processor | +| DU | Distributed Unit as defined by 3GPP | +| FFT | Fast Fourier Transform | +| FH | Fronthaul | +| FHGW | Fronthaul Gateway | +| FHGW <sub>x→y</sub> | Fronthaul Gateway that can translate FH protocol from an O-DU with split option x to an O-RU with split option y, with currently available option 7-2→8. | +| FPGA | Field Programmable Gate Array | +| GbE | Gigabit Ethernet | +| GNSS | Global Navigation Satellite System | +| IEEE | Institute of Electrical and Electronics Engineers | +| I/O | Input/Output | +| LTE | Long Term Evolution | +| MAC | Media Access Control | +| O-CU | O-RAN Centralized Unit as defined by O-RAN | +| OCXO | Oven Controlled Crystal Oscillator | +| O-DU <sub>x</sub> | A specific O-RAN Distributed Unit having fronthaul split option x where x may be 6, 7-2 (as defined by WG4) or 8 | +| O-RU <sub>x</sub> | A specific O-RAN Radio Unit having fronthaul split option x, where x is 6, 7-2 (as defined by WG4) or 8, and which is used in a configuration where the fronthaul interface is the same at the O-DU <sub>x</sub> | +| PCIe | Peripheral Component Interface Express | +| POE | Power over Ethernet | +| RAN | Radio Access Network | +| RF | Radio Frequency | +| RU | Radio Unit as defined by 3GPP | +| RX | Receiver | + +| | | | +|---|------|-----------------------------------------| +| 1 | SFP | Small Form-factor Pluggable | +| 2 | SFP+ | Small Form-factor Pluggable Transceiver | +| 3 | SoC | System On Chip | +| 4 | TX | Transmitter | +| 5 | UL | Uplink | +| 6 | USB | Universal Serial Bus | +| 7 | WG | Working Group | +| 8 | | | + +# Chapter 2 Deployment Scenarios + +O-RAN Working Group 7's deployment scenario specification [1] shows the split architecture as below. The Fronthaul Gateway (FHGW) in this case aggregates multiple O-RUs to a single location consisting of O-DUs. The fronthaul gateway provides protocol translation, packet switching and aggregation capabilities. + +![Figure 1: Base Station with Split Architecture. The diagram shows a Base Station architecture. On the left, a dashed box contains an O-CU and an O-DUx connected by an F1 Interface. This O-DUx is connected to a central FHGWx-y (optional) block via an FH Interfacex. The FHGWx-y block is then connected to multiple O-RUy blocks on the right via FH Interfacey. The O-RUy blocks are also connected to a central vertical line, which is connected to the FHGWx-y block.](b0b88b7bbc3aac4b0de5666690761f98_img.jpg) + +Figure 1: Base Station with Split Architecture. The diagram shows a Base Station architecture. On the left, a dashed box contains an O-CU and an O-DUx connected by an F1 Interface. This O-DUx is connected to a central FHGWx-y (optional) block via an FH Interfacex. The FHGWx-y block is then connected to multiple O-RUy blocks on the right via FH Interfacey. The O-RUy blocks are also connected to a central vertical line, which is connected to the FHGWx-y block. + +**Figure 1: Base Station with Split Architecture** + +This document describes scenarios where the FHGW provides protocol translation in addition to the switching and aggregation capabilities. + +### 2.1.1 Deployment Scenario -1 + +The FHGW (Fronthaul Gateway) may be placed between the O-DU and RU (Radio Unit) with the following O-RAN specified interfaces: + +- The interface between O-DU and FHGW is Open Fronthaul (Option 7-2x). +- The interface between FHGW and RU is an LLS option specified by O-RAN. +- The interface between FHGW and RU may not support Open Fronthaul (Option 7-2x). + +Figure 2 below depicts the deployment of the FHGW using O-RAN specified interfaces. + +![Figure 2: Deployment of O-DU and RU using FHGW. The diagram shows two radio units (RU and O-RU) on the left. The O-RU is connected to a block containing FHGW and L-PHY via an 'Open Fronthaul' link. The RU is connected to the same block via an 'Open CPRI' link. This block is then connected to an O-DU block on the right via a dashed 'Open Fronthaul' link.](b11f52de8b482309b3ca21214097319d_img.jpg) + +Figure 2: Deployment of O-DU and RU using FHGW. The diagram shows two radio units (RU and O-RU) on the left. The O-RU is connected to a block containing FHGW and L-PHY via an 'Open Fronthaul' link. The RU is connected to the same block via an 'Open CPRI' link. This block is then connected to an O-DU block on the right via a dashed 'Open Fronthaul' link. + +**Figure 2: Deployment of O-DU and RU using FHGW** + +The Low PHY function in the fronthaul gateway converts the CPRI/low level split interface between the RU and Open Fronthaul (Option 7-2x). The fronthaul gateway is deployed near the RU physically and gets connected to the DU using a packet-based network. + +The FHGW gateway has radio processing capabilities to do the protocol translation between CPRI/low level split interface and Open Fronthaul (Option 7-2x) and does the translation for the management plane also. The non-O-RAN-RU along with FHGW appears as a single/multiple O-RU(s) to the O-DU. + +The RUs and O-RUs are directly connected to the FHGW. The O-DUs are connected to FHGW over a network. The network between FHGW and O-DU could be a point-to-point, mesh or a ring topology. In some cases, the FHGWs provide transport to non-fronthaul traffic also, namely, midhaul, backhaul or other traffic. So FHGW may have non-fronthaul ethernet interfaces also. + +#### 2.1.1.1 Point to point network + +![Figure 3: Point to point topology for Fronthaul Gateway. The diagram shows a single O-DU block on the right connected to three separate FHGW blocks on the left. Each FHGW block has a single arrow pointing from the O-DU block to it, representing a point-to-point connection.](9127ca154aa701f3acf042b3830e9f40_img.jpg) + +Figure 3: Point to point topology for Fronthaul Gateway. The diagram shows a single O-DU block on the right connected to three separate FHGW blocks on the left. Each FHGW block has a single arrow pointing from the O-DU block to it, representing a point-to-point connection. + +**Figure 3: Point to point topology for Fronthaul Gateway** + +Each fronthaul gateway gets connected to the O-DUs directly. These connections might be direct physical connections or through a packet network. When FHGWs connect through other network elements to the O-DUs, they form a mesh network. + +#### 2.1.1.2 Ring network + +![Figure 4: Ring topology for Fronthaul Gateway. The diagram shows three FHGW (Fronthaul Gateway) blocks arranged in a ring topology, connected by curved arrows. A fourth block, labeled O-DU (Open Distributed Unit), is connected to each of the three FHGW blocks by straight arrows, indicating a direct connection from each gateway to the O-DU.](99908d6b5a589d69819a4de83c3e0105_img.jpg) + +Figure 4: Ring topology for Fronthaul Gateway. The diagram shows three FHGW (Fronthaul Gateway) blocks arranged in a ring topology, connected by curved arrows. A fourth block, labeled O-DU (Open Distributed Unit), is connected to each of the three FHGW blocks by straight arrows, indicating a direct connection from each gateway to the O-DU. + +**Figure 4: Ring topology for Fronthaul Gateway** + +FHGWs form a ring topology and get connected to the O-DUs. In this case, the Fronthaul Gateways need two interfaces for connectivity towards the O-DUs + +### 2.1.2 Low PHY + +The Low PHY module in fronthaul gateway implements the below functionalities. + +- 1) FFT/IFFT (Lower-PHY DL/UL) +- 2) PRACH detection (Lower-PHY UL) +- 3) Handling of C-Plane/M-plane messages +- 4) Timing and synchronization of RU +- 5) eCPRI framing/de-framing and switching +- 6) CPRI framing/de-framing and switching +- 7) CPRI to eCPRI conversion +- 8) I/Q compression on eCPRI and CPRI links + +Doing LowPHY functionality on the FHGWs and converting the low-level split interface to O-RAN fronthaul interface enables connecting legacy RUs to O-DUs. This enables brownfield deployments to leverage the benefits of O-RAN based disaggregated and open networks. + +### 2.1.3 Timing + +The packet based fronthaul network is compliant with the timing requirements described by WG4 CUS specification [2]. The packet-based network uses SyncE and PTP to provide frequency, phase and Time-of-Day to necessary endpoints. It can derive these parameters from satellite-based sources also. The legacy RUs derive frequency and phase through the CPRI/low level split interface connected to the fronthaul gateway. CPRI/low level split interface transports frequency and phase through mechanisms difference from SyncE and PTP. The scheme is specified in the CPRI v7.0 [4] specification and is not vendor specific. + +### 2.1.4 Attributes of FHGW<sub>7-2→8</sub> + +**Table 1: Attributes of FHGW<sub>7-2→8</sub>** + +| Attributes | Values or Assumptions | +|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Functionalities | Packet switching, Radio interface translation | +| Timing Capabilities | Compliant to S-Plane protocol specification in O-RAN-WG4-CUS.0-v04.00 specification | +| Deployment | Outdoor, near Outdoor Macrocell | +| Interfaces | Low level split Interfaces to connect to legacy RU<br>Ethernet interfaces to connect to O-DU<br>Ethernet interfaces to connect to O-RU<br>Timing interfaces | + +# Chapter 3 Hardware Architecture and Requirements + +Fronthaul gateways are deployed near the Radio units where it aggregates multiple Radio Units. In case of brownfield RUs, fronthaul gateway converts the split 8 signals to split-7-2x specified by O-RAN. In macrocell deployment scenarios, the FHGW will cater to xHaul needs as well. So, it will handle diverse traffic streams. + +In this case the fronthaul gateway has digital signal processing capabilities as well as packet switching capabilities. In case of a FHGW, the combination of RU and FHGW acts as an O-RU. + +## 3.1 FHGW<sub>7-2→8</sub> Hardware Architecture + +This section describes the hardware architecture of a fronthaul gateway which supports legacy interfaces towards RUs and provides protocol translation to enable them to connect to O-DUs. In addition to that Fronthaul Gateway provides transportation capabilities for O-RAN fronthaul traffic as well as other types of traffic. + +### 3.1.1 FHGW<sub>7-2→8</sub> Hardware Architecture Diagram + +![Fronthaul Gateway Hardware Architecture Diagram](66326bdd506c866d9a0920e9c5d797e6_img.jpg) + +The diagram illustrates the hardware architecture of a Fronthaul Gateway (FHGW). The main components are: + +- CPU**: Connected to the Network Processing Unit via PCIe. +- Network Processing Unit**: The central processing block. +- Radio Signal Processor**: Connected to the Network Processing Unit via Ethernet. +- Timing and Sync Block**: Provides a Reference Clock to the Network Processing Unit and the Radio Signal Processor. +- Ethernet PHY (Optional)**: Two optional blocks for Ethernet interfaces. + +External interfaces include: + +- Ethernet Interfaces toward O-DU and others**: Connected to the optional Ethernet PHY blocks. +- Low Level split Interfaces toward RU and Ethernet Interfaces toward O-RU**: Connected to the Radio Signal Processor. + +Fronthaul Gateway Hardware Architecture Diagram + +Figure 5: Fronthaul Gateway Hardware Architecture Diagram + +### 3.1.2 FHGW<sub>7-2</sub>→<sub>8</sub> Functional Module Description + +This section describes the functional components of a fronthaul gateway which does protocol translation from non-O-RAN fronthaul interface towards RUs to O-RAN fronthaul interface (split 7-2) towards O-DUs. This fronthaul gateway supports O-RAN fronthaul interface (split 7-2) towards O-RUs and provides transportation for that traffic towards O-DUs. Fronthaul gateway can handle non-Fronthaul traffic also. The selection of specific hardware components for these modules is a product design task. The descriptions and requirements are given below. + +#### Network Processing Unit + +The network processing unit provides the packet transport functions of the FHGW. + +#### Radio Signal Processor/Accelerator + +Radio Signal processor/Accelerator does the protocol translation capabilities required to translate from the low-level split-8 to O-RAN fronthaul interface (Split 7-2). The low-level split interfaces to connect to legacy RUs are connected to Radio Signal Processor/Accelerator. This module implements the Low PHY capabilities mentioned in section 2.1.2. + +The Radio signal processor can be implemented using a FPGA, DSP engine or ASICs. + +#### CPU + +CPU hosts the network operating system (NOS) which controls the transport capabilities and the Radio software which controls the radio signal processor. + +#### Memory + +DDR4 Memory is used to store the runtime data and software for the NOS and Radio software. + +#### Storage + +Non-volatile storage to store operating system, application software, firmware, operational status of Fronthaul Gateway. This could be implemented using Flash or SSD. + +#### Timing Components + +The timing module in the FHGW board is used to implement IEEE 1588 PTP and Synchronous Ethernet functionalities. This module recovers timing and provides synchronization to other modules. The module consists of below key components + +1. GNSS +2. OCXO +3. DPLL +4. Servo + +*GNSS* - Global Navigation Satellite System provides Time of the Day and Synchronization pulse (PPS) to the timing module to recover the clock and phase. This will be the primary reference clock (PRC) when selected as source of timing to the timing module + +*OCXO* - Oven controlled crystal oscillator provides the stable reference clock to the timing module with reference to which the PTP clock is generated. This clock also is used to validate the other recovered clocks are within the required PPM offset or not + +*DPLL* - Digital Phase lock loop circuit is used to generate the PTP clock steered by the servo algorithm. This ensures that the generated clock meets the required specifications in terms of Jitter, Phase alignment and + +meet the necessary masks of the ITU-T specs. This component also regenerates the required local clocks from the SyncE recovered clocks from the Phys or from the generated PTP clock or GNSS clock + +*Servo* - This is a SW component running in the CPU or any programmable engine which analyses the timestamps from the ethernet packets, performs appropriate filtering and steers the DPLL to generate the PTP clock and Phase alignment of the clock to the primary clock source. + +#### Ethernet PHY + +This is an optional component to provide physical level ethernet connectivity. In some cases, the Network processing unit itself provides this capability and discrete ethernet PHYs are not required. + +### 3.1.3 FHGW<sub>7-2→8</sub> Interfaces + +#### Legacy Low-Level Split Interfaces + +These interfaces are used to connect to legacy/brownfield RUs. They use protocols other than O-RAN fronthaul (Split 7-2) interface. They carry time domain Radio signals. CPRI is a typical split-8 protocol used by legacy RUs. + +#### PCIe Interface + +Support for PCIe v3 and later interface. The bandwidth depends on the use cases. It is as the control plane interface for NPUs and Radio signal processors through which the CPU controls and maintains them. + +#### Timing Interfaces + +As mentioned earlier, the timing modules provide reference timing signals to various components of the Fronthaul Gateway system. The interfaces used to provide the signals to NPU, and Radio signal processor should be specified + +#### Ethernet Interfaces + +Ethernet interfaces are used to connect to O-RUs, O-DUs and other elements in the transport network. Apart from the external interfaces, ethernet is used between the NPU and Radio signal processing unit. The bandwidth of these interfaces depends on specific use cases. + +## 3.2 Disaggregation and Modularity Requirements + +The Fronthaul gateway is implemented by combining transport and radio functions to provide both capabilities. The FHGW shall be modular enough for these two functions to be implemented separately – potentially by different vendors. This enables experts in transport and radio areas to come together and create FHGWs with flexible and programmable radio plane. In order to enable that the interfaces between transport and radio functions should be clearly defined. Below is the list of such internal interfaces. + +This modularity enables multiple instances of those radio functions to be present in the FHGW. This enables increasing the scale of radio processing in the FHGW as well as integrating different Radio processing capabilities from the same different implementors. + +### 3.2.1 Internal Interfaces + +![Figure 6: Fronthaul Gateway Architecture with Internal Open interfaces. The diagram shows a block diagram of a fronthaul gateway architecture. A central 'Network Processing Unit' is connected to a 'CPU' via a 'PCIe' interface. The 'Network Processing Unit' is also connected to a 'Radio Signal Processor' via an 'Ethernet' interface. A 'Timing and Sync Block' provides a 'Reference Clock' to both the 'Network Processing Unit' and the 'Radio Signal Processor'. External interfaces include 'Ethernet PHY (Optional)' blocks for 'Ethernet Interfaces toward O-DU and others' and 'Ethernet Interfaces toward O-RU and others'. A 'Low Level split Interfaces toward RU and Ethernet Interfaces toward O-RU' are also shown. Dotted ovals highlight the 'PCIe' and 'Ethernet' interfaces between the Network Processing Unit and the Radio Signal Processor, indicating open hardware interfaces.](bc3d7c1b78e13de258420c36406fb1fb_img.jpg) + +Figure 6: Fronthaul Gateway Architecture with Internal Open interfaces. The diagram shows a block diagram of a fronthaul gateway architecture. A central 'Network Processing Unit' is connected to a 'CPU' via a 'PCIe' interface. The 'Network Processing Unit' is also connected to a 'Radio Signal Processor' via an 'Ethernet' interface. A 'Timing and Sync Block' provides a 'Reference Clock' to both the 'Network Processing Unit' and the 'Radio Signal Processor'. External interfaces include 'Ethernet PHY (Optional)' blocks for 'Ethernet Interfaces toward O-DU and others' and 'Ethernet Interfaces toward O-RU and others'. A 'Low Level split Interfaces toward RU and Ethernet Interfaces toward O-RU' are also shown. Dotted ovals highlight the 'PCIe' and 'Ethernet' interfaces between the Network Processing Unit and the Radio Signal Processor, indicating open hardware interfaces. + +**Figure 6: Fronthaul Gateway Architecture with Internal Open interfaces** + +Open hardware interfaces to enable a modular fronthaul gateway are given below. They are marked with dotted oval in Figure 6. + +1. Datapath interface between the Radio signal processor and Network processing unit +2. Timing interface for Radio signal processor +3. Interrupt interfaces of the radio signal processor +4. Control plane access to the radio signal processor for control, maintenance and firmware management + +## 3.3 FHGW<sub>7-2→8</sub> Hardware/Performance Requirements + +**Table 2: FHGW<sub>7-2→8</sub> Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------------------------------------|------------------------------------------------------------------------------|------------------------|----------| +| Transport capacity | FHGW shall support 300Gbps of switching | Transport capacity | High | +| Timing requirements | Class C compliance | Timing Requirements | High | +| Radio protocol translation capabilities | The FHGW shall support 240MHz of translation between O-RAN 7-2x and Split 8. | Radio BW capacity | High | +| Antenna Carriers | The FHGW shall support translation of 12 Antenna carriers (AxCs) | Radio Antenna capacity | High | + +### 3.3.1 FHGW<sub>7-2→8</sub> Interface Requirements + +**Table 3: FHGW<sub>7-2→8</sub> Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------|----------| +| O-RAN Fronthaul interfaces | FHGW shall support Ethernet interfaces with speeds from 10G to 25G. These interfaces will support transport of Fronthaul haul traffic compliant to O-RAN 7-2x spec: Control, User, and Synchronization Plane Technical Specification of O-RAN: O-RAN-WG4.CUS.0 [2]<br>Below are the requirements:<br>6x 10G eCPRI interfaces (each port shall support 2 carriers of 20MHz i.e. total of 40MHz)<br>3x 25/10G eCPRI interfaces (each port shall support 1 carrier of 100MHz) | O-RAN FH Interfaces | High | +| Transport interfaces | FHGW shall support ethernet interfaces with speeds from 10G to 100G. These could act as O-RAN fronthaul interfaces as well.<br>Below are the requirements:<br>4x25G/10G interfaces<br>2x10G interfaces<br>2x1G interfaces | Transport interfaces | High | +| Timing Interfaces | IEEE 1588v2 and SyncE on all ethernet interfaces. In addition, it shall/may support GNSS connectivity. | Timing Interfaces | High | +| Low Level Split interfaces | FHGW shall support interfaces to connect to legacy/brownfield RUs.<br>6x 10G legacy and non-legacy CPRI interfaces to support 1 carrier of 20MHz (capability to re-configure legacy and non-legacy CPRI interfaces to eCPRI interfaces)<br>3x 10G legacy and non-legacy CPRI interfaces to support 2 carriers of 20MHz i.e. total 40MHz (capability to re-configure legacy and non-legacy CPRI interfaces to eCPRI interfaces) | CPRI interfaces with rates from 2 to 8 | High | + +| | | | | +|---------------------------------|-----------------------------------------------------------------------------------------------------------------------------|-----------------|------| +| Programmable Radio processor | Radio processor's parameters shall be able to be changed. FHGW shall be able to re-program radio processing function logic. | Programmability | High | +| Adaptability of Radio processor | The Radio processor's firmware shall be reprogrammable in the field. | Adaptability | High | + +Below diagram summarises the requirement given above + +![Diagram showing the interface requirements between RU/O-RU and FHGW. The RU/O-RU is connected to the FHGW via four parallel interfaces: 6x10G CPRI (20 MHz) 6AxC, 3x10G CPRI (2x20 MHz) 6AxC, 6x10G eCPRI (2x20 MHz) 12AxC, and 3x25/10G eCPRI (100 MHz) 3AxC. The FHGW is also connected to the O-DU via a 4x25G eCPRI 12AxC interface.](74f371f8cb4295a373273cce381daf2a_img.jpg) + +Diagram showing the interface requirements between RU/O-RU and FHGW. The RU/O-RU is connected to the FHGW via four parallel interfaces: 6x10G CPRI (20 MHz) 6AxC, 3x10G CPRI (2x20 MHz) 6AxC, 6x10G eCPRI (2x20 MHz) 12AxC, and 3x25/10G eCPRI (100 MHz) 3AxC. The FHGW is also connected to the O-DU via a 4x25G eCPRI 12AxC interface. + +Figure 7: FHGW<sub>7-2→8</sub> Interface requirements + +### 3.3.2 FHGW<sub>7-2→8</sub> : Mechanical, Thermal and Power Requirements + +Table 4: FHGW<sub>7-2→8</sub>: Mechanical, Thermal and Power Requirements + +| Parameter | Requirement | Description | Priority | +|--------------|----------------|-------------|----------| +| Power Supply | -48V DC | | High | +| Temperature | -20°C to +55°C | | High | + +## 3.4 Timing Requirements + +CPRI/Low Level Interface carries Radio data using a constant stream of data. Frequency and Phase are carried from the Fronthaul Gateway to the RUs using the delimiters/control characters on this bit stream. The interval of these control characters depicts the frequency, and the exact positioning of these characters carry phase information. Please refer to the CPRI specification [4] for more details. + +The Fronthaul Gateway should derive these parameters from the O-DUs using IEEE 1588 PTP and SyncE or should be in sync with the O-DUs using IEEE 1588 PTP and SyncE. Then, Fronthaul Gateway should translate the above to the frequency and placement of control characters on the CPRI/Low level split interface. This way, RUs can be synchronised to the rest of the network. + +## 3.5 Security Requirements + +Fronthaul gateway merges the transport and radio functions to provide protocol translation capabilities and network capabilities. The software and firmware for transport and radio capabilities may be implemented by different vendors. So, it is important to verify the authenticity of the software and firmware used in this fronthaul gateway. + +- 1 The Fronthaul gateway shall support secure storage of keys and certificates in a hardware chip and +- 2 will create a secure boot and operating environment where the software and firmware loaded in it +- 3 are securely signed. +- 4 + +# Chapter 4 Hardware Reference Design + +This chapter describes one example of white box hardware reference design for the fronthaul gateway when translating split option 7-2x→8 and vice versa. + +## 4.1 FHGW<sub>7-2→8</sub> Hardware Reference Design + +This section describes the design of a fronthaul gateway which supports both legacy interfaces (i.e., CPRI) towards RUs and NR eCPRI interfaces toward O-RUs. When connecting to legacy RUs, it provides protocol translation to enable them to be operating with O-DUs. In addition, the FHGW provides transport capabilities for O-RAN fronthaul traffic as well as other types of traffic. + +## 4.2 FHGW<sub>7-2→8</sub> High Level Functional Block Diagram + +The high-level architecture of a generic FHGW with L× Ethernet/eCPRI connections toward the O-DU, N× CPRI links toward legacy RU/RRHs, M× Ethernet/eCPRI connections toward O-RUs is shown in Figure 8. It's worth mentioning that some or all of the N×CPRI interfaces are capable of supporting O-RAN/eCPRI fronthaul interfaces through dynamic reconfiguration. Note that depending on the number of the links, the specs and number of the CPU, NPU and FPGAs used in this hardware reference design may change. + +![High-level Functional Block Diagram of the FHGW](ee9eb0bd29ac99e96086d5b26c66b3e3_img.jpg) + +The diagram illustrates the high-level functional architecture of the FHGW. The main components and their interconnections are as follows: + +- External Connections:** + - Ethernet, USB, Console Connections:** Connected to the **CPU+DRAM/FLASH** block via a bidirectional arrow. + - External Timing and 10Mhz Connections:** Connected to the **Timing and Sync Block** via a bidirectional arrow. +- Internal Blocks:** + - CPU+DRAM/FLASH:** The central processing and storage unit. + - Network Processing Unit (NPU):** Connected to the CPU via **PCIe** and **Ethernet** interfaces. + - Radio Signal Processor (RSP):** Connected to the NPU via **Ethernet** and to the Timing and Sync Block via a **Reference Clock**. + - Timing and Sync Block (GPS, 1PPS, SyncE, IEEE 1588):** Provides timing and synchronization to the RSP and the NPU. +- Interfaces:** + - Ethernet PHY:** Two blocks are shown, one on the left and one on the right, connected to the NPU and RSP respectively. + - MxSFP+/SFP28 Connectors:** Located on the right, for Ethernet interfaces toward O-RU(s) and others. + - NxSFP+/SFP28 Connectors:** Located on the right, for CPRI interfaces toward RUs and Ethernet interfaces toward O-RU. + - LxSFP+/SFP28 Connectors:** Located on the left, for Ethernet interfaces toward O-DU(s) and others. + +High-level Functional Block Diagram of the FHGW + +Figure 8: High-level Functional Block Diagram of the FHGW + +## 4.3 FHGW<sub>7-2</sub>→<sub>8</sub> Hardware Components + +### 4.3.1 CPU + +The CPU runs the network operating system (NOS) for the transport functions of the FHGW and handles the control and management functions of the radio signal processor which in this example is an FPGA (including the FPGA driver). A general-purpose CPU (x86 or ARM based) with at least 8 cores can handle these functions. The requirements for the CPU are listed in the following table. + +**Table 5: CPU Features** + +| Item Name | Description | +|-----------------------------------|-----------------------| +| Minimum number of Cores | 4-8 | +| Minimum number of Threads | 8 | +| Base Clock Frequency | 1.60-1.70 GHZ | +| Max Turbo Frequency | 1.70-2.20 GHz | +| Minimum L2 Cache | 6-16 MB | +| Total Power Dissipation | 17 – 25 W | +| Memory Types | DDR4-2666 (PC4-21300) | +| Maximum number of Memory Channels | 2 | + +### 4.3.2 Memory and Storage for CPU + +**Table 6: Memory and Storage Requirements** + +| Item Name | Description | +|-----------|------------------------| +| Memory | 8 GB DDR4 memory | +| Storage | 32 GB eMMC/SSD storage | + +### 4.3.3 Network Processing Unit (NPU) + +The network processing unit in the FHGW handles different types of traffic, terminates Ethernet connections, and interfaces with the radio signal processing unit in order to transport data between the O-DU and legacy RUs following protocol translation in radio signal processor. The example reference design uses an NPU with the following capabilities. + +Table 7: NPU Features + +| Item Name | Description | +|-----------------------------------|------------------------------------------------------------------------------------------------------------------| +| Switching capacity | 300-410 Gbps | +| Network interfaces | 1G, 10G, 25G, 40G, 100G<br>48x10G/16x40G/4x100G | +| External Packet buffer (Optional) | Deep buffering, DDR4, GDDR5 | +| OAM | Hardware based OAM | +| Other Features | Layer2 through Layer4 processing with integrated deep-buffer traffic management, Large on-chip forwarding tables | + +### 4.3.4 Radio Signal Processor - FPGA + +Radio signal processor implements the protocol conversion between the split option 8 (CPRI) protocols used by legacy RUs and Open Fronthaul O-RAN7-2x interface (eCPRI). The functions are hosted and processed in the radio signal processor, which in this example design is an FPGA: + +- 1) FFT/IFFT (Lower-PHY DL/UL) +- 2) PRACH detection (Lower-PHY UL) +- 3) Handling of C-Plane/M-plane messages +- 4) Timing and synchronization of RU +- 5) eCPRI framing/de-framing and switching +- 6) CPRI framing/de-framing and switching +- 7) CPRI to eCPRI conversion +- 8) I/Q compression on eCPRI and CPRI links + +#### 4.3.4.1 Radio signal processor – FPGA reference model 1 + +The physical resources (LUT, BRAM, URAM, DSP48, etc.) required on the FPGA depends on the number, speed and type of the legacy interfaces for which protocol conversion are performed. Figure 8 shows the functional block diagram of the FHGW reference design. + +![Figure 9: Radio Signal Processing Block Diagram – FPGA Model-1. The diagram shows a functional block diagram of a radio signal processor (FPGA) enclosed in a dashed box. It features two main data paths: Downlink (top) and Uplink (bottom). The Downlink path starts with 'eCPRI De-Framer/Interface' and 'AXI Stream FIFOs', followed by 'Delay with AxC Mapping', 'I/Q De-Compression', 'IFFT CP Insertion', 'AxC Distribution', 'I/Q Compression' (dashed box), and 'CPRI Framer/Interface' leading to 'Nx CPRI Output'. The Uplink path starts with 'Nx CPRI Input' and 'CPRI De-Framer/Interface', followed by 'I/Q De-Compression' (dashed box), 'AxC Aggregation', 'FFT CP Removal' and 'PRACH Filtering', 'I/Q Compression', 'Delay with AxC Mapping', 'AXI Stream FIFOs', and 'eCPRI Framer/Interface' leading to 'eCPRI Input/Output'. Buffers are placed at the start of each path: 'Downlink Buffer (1)' and 'Downlink Buffer (2)' for the downlink, and 'Uplink Buffer (1)' and 'Uplink Buffer (2)' for the uplink. Arrows indicate the direction of data flow between these blocks.](9bf681a2babc07b4a996bc57f05adca2_img.jpg) + +Figure 9: Radio Signal Processing Block Diagram – FPGA Model-1. The diagram shows a functional block diagram of a radio signal processor (FPGA) enclosed in a dashed box. It features two main data paths: Downlink (top) and Uplink (bottom). The Downlink path starts with 'eCPRI De-Framer/Interface' and 'AXI Stream FIFOs', followed by 'Delay with AxC Mapping', 'I/Q De-Compression', 'IFFT CP Insertion', 'AxC Distribution', 'I/Q Compression' (dashed box), and 'CPRI Framer/Interface' leading to 'Nx CPRI Output'. The Uplink path starts with 'Nx CPRI Input' and 'CPRI De-Framer/Interface', followed by 'I/Q De-Compression' (dashed box), 'AxC Aggregation', 'FFT CP Removal' and 'PRACH Filtering', 'I/Q Compression', 'Delay with AxC Mapping', 'AXI Stream FIFOs', and 'eCPRI Framer/Interface' leading to 'eCPRI Input/Output'. Buffers are placed at the start of each path: 'Downlink Buffer (1)' and 'Downlink Buffer (2)' for the downlink, and 'Uplink Buffer (1)' and 'Uplink Buffer (2)' for the uplink. Arrows indicate the direction of data flow between these blocks. + +Figure 9: Radio Signal Processing Block Diagram – FPGA Model-1 + +##### 4.3.4.1.1 FPGA Resource Estimation + +Based on the operator requirements, we define the external connections/ports and interfaces to FHGW as shown in Figure 7. + +The required number of CPRI or eCPRI [mutually exclusive] connections between the FHGW and RUs or O-RUs, respectively, would be fulfilled with 12AxC each carrier with 20MHz bandwidth for the legacy RU operation and 2x20MHz or 100MHz for the O-RU operation, which will be used in the following to calculate the FPGA resources. In this specification, we focus only on legacy RU support, thus only taking into consideration the gateway functionality of the FHGW and not the multiplexing functionality. Considering the functions that are shown in Figure 9 and the external interfaces shown in Figure 7, the reference implementation on FPGA would require hardware resources (SERDES, Flip Flops, Lookup Tables, DSPs, Block RAM, etc.) as shown in Table 8. As an example, we are assuming one LTE carrier with 20MHz of bandwidth and 1TRX antenna configuration is processed in FPGA. In time-domain, the fronthaul bandwidth of each LTE 20MHz carrier is $30.72\text{Msps} \times 1 \text{ Antennas} \times 32\text{bits/sample} \times 66/64 \text{ coding} = 1.014\text{Gbps}$ , thus without I/Q compression, one 25Gbps fronthaul link can accommodate 24AxC. If a 2:1 ratio time-domain I/Q compression is used, 48AxC can be accommodated. Note that increasing the number of transceivers and/or the number of 20MHz LTE carriers would scale the number of required AxC. + +The buffering requirements in block diagram of Figure 9 for 12AxC is 4.54Mbit and will be scaled with the number of AxC. + +**Table 8: Estimated FPGA Resource Allocation for the Designated Functions - 1** + +| | Number of Instances | FF | LUT | DSP48 | BRAM 18kb | URAM 288kb | Total FF | Total LUT | Total DSP48 | Total BRAM 18kb | Total URAM 288kb | Notes | +|--------------------------------------------------------|---------------------|------|------|-------|-----------|------------|---------------|--------------|-------------|-----------------|------------------|--------------------------------------------------------------------------------------------------------------------------------------------| +| Sample-Rate Conversion (SRC) Filter | 4 | 5000 | 3000 | 24 | 0 | 0 | 20000 | 12000 | 96 | 0 | 0 | Each instance supports 3 carriers of 2T2R 20MHz at 368.72MHz clock (6 AxC); thus we need 2 instances for downlink and uplink, respectively | +| Block-wise Quant | 2 | 4000 | 3000 | 12 | 16 | 0 | 8000 | 6000 | 24 | 32 | 0 | Running at 368MHz. One instance for 6 I/Q streams (6 AxC) | +| Block-wise deQuant | 2 | 3000 | 2000 | 8 | 10 | 0 | 6000 | 4000 | 16 | 20 | 0 | Running at 368MHz. One instance for 6 I/Q streams (6 AxC) | +| CPRI Framing/De-framing | 12 | 8000 | 3000 | 0 | 12 | 0 | 96000 | 36000 | 0 | 144 | 0 | Each instance supports one 10G CPRI | +| <b>Time-domain Compression/Decompression Sub-total</b> | | | | | | | <b>130000</b> | <b>58000</b> | <b>136</b> | <b>196</b> | <b>0</b> | | +| IFFT | 1 | 5763 | 3723 | 15 | 11 | 0 | 5763 | 3723 | 15 | 11 | 0 | Each instance supports 6 carriers of 2T2R 20MHz at 368.72MHz clock | +| Add CP | 1 | 2000 | 1000 | 0 | 2 | 6 | 2000 | 1000 | 0 | 2 | 6 | 12 OFDM symbols x 2048 samples x 32 bits x 2 dual-port memory | + +| | | | | | | | | | | | | | +|----------------------|---|------|------|----|----|---|-------|-------|-----|----|----|------------------------------------------------------------------------------------| +| | | | | | | | | | | | | read/write = 1.536Mb | +| FFT | 1 | 5763 | 3723 | 15 | 11 | 0 | 5763 | 3723 | 15 | 11 | 0 | Each instance supports 6 carriers of 2T2R 20MHz at 368.72MHz clock | +| CP Removal | 1 | 2000 | 1000 | 0 | 2 | 6 | 2000 | 1000 | 0 | 2 | 6 | 12 OFDM symbols x 2048 samples x 32 bits x 2 dual-port memory read/write = 1.536Mb | +| Mu-law Compression | 2 | 3000 | 2000 | 4 | 4 | 0 | 6000 | 4000 | 8 | 8 | 0 | Mu-law compression is mainly based on look-up tables | +| Mu-law Decompression | 2 | 2000 | 1500 | 4 | 4 | 0 | 4000 | 3000 | 8 | 8 | 0 | Mu-law decompression is mainly based on look-up tables | +| PRACH Filtering | 2 | 5000 | 4000 | 50 | 12 | 0 | 10000 | 8000 | 100 | 24 | 0 | Decimate Rx signal by 16 and send to O-DU for further processing | +| Low-PHY Sub-total | | | | | | | 35526 | 24446 | 146 | 66 | 12 | | + +Depending on the selected CPRI line rate, the number of LTE 20MHz carriers that can be supported may vary. Table 9 shows the correspondence between the number of LTE 20MHz carriers and the CPRI line rate. + +**Table 9: CPRI Rate Options and the Number of Supported LTE 20MHz Carriers (AxC)** + +| CPRI Line Rate | Line Bit Rate | Line Coding | Bits per Word | Transport Capacity<br>(Number of 20 MHz LTE Ax C Streams) | +|----------------|---------------|-------------|---------------|-----------------------------------------------------------| +| Rate-1 | 0.6144 Gbps | 8B/10B | 8 | - | +| Rate-2 | 1.2288 Gbps | 8B/10B | 16 | 1 | +| Rate-3 | 2.4576 Gbps | 8B/10B | 32 | 2 | +| Rate-4 | 3.0720 Gbps | 8B/10B | 40 | 2 | +| Rate-5 | 4.9152 Gbps | 8B/10B | 64 | 4 | +| Rate-6 | 6.1440 Gbps | 8B/10B | 80 | 5 | +| Rate-7 | 9.8304 Gbps | 8B/10B | 128 | 8 | +| Rate-8 | 10.1376 Gbps | 64B/66B | 160 | 10 | +| Rate-9 | 12.1651 Gbps | 64B/66B | 192 | 12 | +| Rate-10 | 24.3302 Gbps | 64B/66B | 384 | 24 | + +#### 4.3.4.2 Radio signal processor – FPGA reference model 2 + +Figure 10 shows the top-level architecture for a reference radio signal processor. A brief description of each block is also included below. + +![Figure 10: Radio Signal Processing Block Diagram – FPGA Model-2. The diagram shows the flow of radio signal processing within a radio signal processing datapath. It includes components like Ethernet link to NPU, Ethernet (MAC+PHY), eCPRI IP, O-RAN IP, Uplink Arbitrator, PRACH buffer, PRACH, AxC Channelizer, PRACH IP Wrapper, UL buffer, HSC shift* + CP removal + FFT, FFT scheduler, Basic Frame de-MUX, CPRI IQ deMapper, FDV buffer, iFFT scheduler, iFFT + CP insertion, Basic Frame MUX, CPRI IQ Mapper, and CPRI interface IP. The diagram also shows the connection to the RU (Radio Unit) via CPRI interface IP.](f53a63e67722f2773ec44512a5fedbc0_img.jpg) + +Figure 10: Radio Signal Processing Block Diagram – FPGA Model-2. The diagram shows the flow of radio signal processing within a radio signal processing datapath. It includes components like Ethernet link to NPU, Ethernet (MAC+PHY), eCPRI IP, O-RAN IP, Uplink Arbitrator, PRACH buffer, PRACH, AxC Channelizer, PRACH IP Wrapper, UL buffer, HSC shift\* + CP removal + FFT, FFT scheduler, Basic Frame de-MUX, CPRI IQ deMapper, FDV buffer, iFFT scheduler, iFFT + CP insertion, Basic Frame MUX, CPRI IQ Mapper, and CPRI interface IP. The diagram also shows the connection to the RU (Radio Unit) via CPRI interface IP. + +Figure 10: Radio Signal Processing Block Diagram – FPGA Model-2 + +##### 4.3.4.2.1 FPGA Resource Estimation + +Based on the operator requirements, we define the external connections/ports and interfaces to FHGW as shown in Figure 10. It is based on a reference implementation of a radio signal processor using different number of AxC processing capability. + +The resource estimation below only considers the functionality required to provide legacy RU, or CPRI radio support. The implementation is based on the architecture depicted in Figure 10. + +Considering the requirements summarized in Table 2, the number of AxCs is 12 of 20MHz LTE signals. Therefore, the O-RAN fronthaul traffic by assuming split 7.2, can be calculated as follows + +$$ORAN\ traffic = [12\ (AxCs) \times 14\ (symbols) \times 1200\ (REs) \times 32\ (bisIQ)] / 1\ ms + C/S/M-plane + Pkt\_header\ overhead \sim 6.5\ Gbps$$ + +On the Ethernet link connecting to NPU or O-DU direction, one 10GE link is sufficient to accommodate the traffic. However, in our example implementation, one 25GE link is still used for scalability when more AxCs are required. Using the same calculation, one 25G link can accommodate 36 AxCs or 20MHz LTE signal using split 7.2. + +Table 10 shows the estimated resource utilization (logic ALMs, DSP blocks, RAM blocks, ALUTs) for the implementation architecture from Figure 3 with respect to 12 AxCs of 20MHz signal. + +Table 10: Estimated FPGA Resource Allocation for the Designated Functions - 2 + +| | Logic (ALMs) | DSP Blocks | Registers | RAM Blocks (M20 K) | ALUTs | comments | +|-------------------------------|--------------|------------|-----------|--------------------|--------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 25GE (soft MAC) | 7,306 | 1 | 17,021 | 24 | 9,732 | some FPGA devices implement the MAC in hard logic, therefore eliminating the usage for soft MAC | +| eCPRI IP | 4,511 | 0 | 10,184 | 25 | 5,918 | The eCPRI and O-RAN IP implement the eCPRI (de)framer and O-RAN (de)mapper separately. The eCPRI and O-RAN IP are dimensioned for 25GE link. More instances are needed only if more 25GE links are required. Please refer to the throughput calculation above in this subsection | +| O-RAN IP with (De)compression | 35,352 | 0 | 78,411 | 15 | 36,527 | | + +| | | | | | | | +|--------------------------------------|--------|-----|---------|-----|---------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>DL iFFT/CP</b> | 3,287 | 21 | 9,540 | 24 | 3,625 | This group of blocks implement the Low PHY signal processing in DL direction. An FDV buffer is included to compensate the delay variations between FHGW and O-DU.<br>Scale in general by the number of AxCs. The reference implementation consists of processing engines where each engine can process multiple AxCs | +| <b>DL FDV buffering</b> | 6,518 | 0 | 23,550 | 144 | 2,616 | | +| <b>iFFT scheduler</b> | 68 | 0 | 237 | 0 | 32 | | +| <b>Basic Frame Mux</b> | 1,338 | 0 | 4,358 | 90 | 2,118 | | +| <b>CPRI IP wrapper (9 instances)</b> | 21,631 | 0 | 46,717 | 108 | 26,991 | Scale by the number of CPRI interfaces | +| <b>Basic frame de-mux</b> | 2,025 | 0 | 6,177 | 90 | 2,160 | This group of blocks implement the low PHY signal processing in uplink including PRACH.<br>Scale in general by the number of AxCs. The reference implementation consists of processing engines where each engine can process multiple AxCs | +| <b>UL FFT/CP</b> | 3,910 | 27 | 10,723 | 11 | 4,507 | | +| <b>Uplink arbiter</b> | 649 | 0 | 2,102 | 40 | 452 | | +| <b>FFT scheduler</b> | 87 | 0 | 251 | 0 | 219 | | +| <b>PRACH IP wrapper</b> | 11,667 | 53 | 25,000 | 208 | 16,667 | | +| <b>Total</b> | 98,347 | 102 | 234,271 | 779 | 111,563 | 1x 25GE link, 9x CPRI links, 12 AxCs of 20MHz | + +## 4.4 Interfaces on Radio Signal Processor + +### 4.4.1 Interface towards the NPU + +The radio signal processing FPGA and the network processing unit are connected via Ethernet interfaces. The FPGA sends O-RAN 7-2x fronthaul packets to the NPU so that they can be transported to the O-DU<sub>7-2</sub> and the NPU sends O-RAN 7-2x fronthaul packets coming from O-DU<sub>7-2</sub> to the FPGA via Ethernet connection. The number and the bandwidth of these Ethernet links depends on the following conditions: + +1. The number and speed (rate) of legacy CPRI interfaces toward RUs +2. The number of antenna carriers (AxC) and their respective bandwidth +3. Compression parameters on the FPGA's protocol conversion logic +4. The stream identification scheme used between FPGA and NPU + - a. All converted streams from an RU/RRH can be sent on a separate ethernet link. Simple, but uses more resources than needed. + - b. Each converted stream can be sent on a soft channel (VLAN based) on any of the Ethernet links. This requires some multiplexing and load balancing logic in both FPGA and NPU. +5. If the front panel interfaces on the FPGA needs to act as Ethernet interfaces, they need to have one to one internal interface toward the NPU. The internal interface should match the speed of front panel interface. + +Depending on the above factors, there could be nx10/25G Ethernet links between the NPU and FPGA. + +![Figure 11: Internal Ethernet Links between NPU and FPGA. The diagram shows an NPU block on the left and a Radio Signal Processor FPGA block on the right. They are connected by multiple bidirectional arrows labeled 'n x 10G/25G Ethernet ports'. The NPU has 'Ethernet Ports' on its left side, and the FPGA has 'Legacy Ports toward RU or Ethernet Ports toward O-RU' on its right side.](343611df4fcd20294b88d83667a75bdf_img.jpg) + +Figure 11: Internal Ethernet Links between NPU and FPGA. The diagram shows an NPU block on the left and a Radio Signal Processor FPGA block on the right. They are connected by multiple bidirectional arrows labeled 'n x 10G/25G Ethernet ports'. The NPU has 'Ethernet Ports' on its left side, and the FPGA has 'Legacy Ports toward RU or Ethernet Ports toward O-RU' on its right side. + +**Figure 11: Internal Ethernet Links between NPU and FPGA** + +The management-plane traffic from the FPGA towards the radio control and management software running on the CPU also traverses through these Ethernet interfaces. The NPU will switch/route these packets towards the radio control and management software. + +### 4.4.2 Timing and Synchronization + +The timing and synchronization architecture of FHGW<sub>7-2→8</sub> looks like below. + +![Figure 12: Timing Circuitry. The diagram shows a CPU block and a SETS PLL & Timing block at the top. They are connected by a bidirectional arrow labeled 'PTP/1588 Servo control'. Below them is a 'Timing Bus' that connects to both the CPU and the SETS PLL & Timing block. At the bottom, there is an NPU block and a Radio Signal Processor FPGA block. They are connected by a bidirectional arrow labeled 'Internal Ethernet'. The NPU has 'Ethernet Ports toward O-DU/O-RU and others' on its left side, and the FPGA has 'Legacy Ports toward RU or Ethernet Ports toward O-RU' on its right side. The Timing Bus also connects to both the NPU and the FPGA.](b403c896d250245e768c3bcec7aaef2f_img.jpg) + +Figure 12: Timing Circuitry. The diagram shows a CPU block and a SETS PLL & Timing block at the top. They are connected by a bidirectional arrow labeled 'PTP/1588 Servo control'. Below them is a 'Timing Bus' that connects to both the CPU and the SETS PLL & Timing block. At the bottom, there is an NPU block and a Radio Signal Processor FPGA block. They are connected by a bidirectional arrow labeled 'Internal Ethernet'. The NPU has 'Ethernet Ports toward O-DU/O-RU and others' on its left side, and the FPGA has 'Legacy Ports toward RU or Ethernet Ports toward O-RU' on its right side. The Timing Bus also connects to both the NPU and the FPGA. + +**Figure 12: Timing Circuitry** + +The timing bus provides the following signals to the NPU and the FPGA + +1. A reference clock signal to the NPU and FPGA at predetermined frequency from PTP domain. +2. A One-Pulse per Second (PPS) reference signal where the transition from low to high as sampled by the clock is the second's marker +3. A lower speed bus carrying the seconds value of Time of Day. The 48 bits of seconds value is provided serially on this signal. + +### 4.4.3 Security + +Fronthaul gateway shall include latest Trusted Platform Module (TPM) – 2.0 or greater – to store keys and certificates and to authenticate digitally signed software and firmware modules. This enables creating a secure environment where non-secure software or firmware cannot be loaded on the fronthaul gateway. + +### 4.4.4 PCIe Interface + +The FPGA is connected to the CPU via a PCIe interface for control and configuration access. During the initialization stage, the CPU detects and enumerates the FPGA as a PCIe device and sets up the access for software drivers and applications to configure, control and manage the device. + +![Figure 13: PCIe Interface to FPGA. The diagram shows a CPU connected to an NPU and a Radio Signal Processor FPGA. The CPU is connected to the NPU via a PCIe interface. The NPU is connected to the Radio Signal Processor FPGA via an Internal Ethernet interface. The NPU has Ethernet Ports toward O-DU/O-RU and others. The Radio Signal Processor FPGA has Legacy Ports toward RU or Ethernet Ports toward O-RU.](524deb0abd39afd6173b82156e88a85e_img.jpg) + +``` + +graph TD + CPU[CPU] <-->|PCIe| NPU[NPU] + NPU <-->|Internal Ethernet| RSF[Radio Signal Processor FPGA] + NPU --> EP[Ethernet Ports toward O-DU/O-RU and others] + RSF --> LP[Legacy Ports toward RU or Ethernet Ports toward O-RU] + +``` + +Figure 13: PCIe Interface to FPGA. The diagram shows a CPU connected to an NPU and a Radio Signal Processor FPGA. The CPU is connected to the NPU via a PCIe interface. The NPU is connected to the Radio Signal Processor FPGA via an Internal Ethernet interface. The NPU has Ethernet Ports toward O-DU/O-RU and others. The Radio Signal Processor FPGA has Legacy Ports toward RU or Ethernet Ports toward O-RU. + +Figure 13: PCIe Interface to FPGA + +### 4.4.5 Example Pinout of a Radio Signal Processor FPGA + +Table 11: Example Pinout of the FPGA + +| Port | Direction | Description | +|--------------------------------------------------------------------------------------------------------------------------|-----------|---------------------------------------| +| DEV_TYP[1:0] | input | Device type | +| DEV_INST[1:0] | input | Device instance | +| CLK_100M_FPGA_P<br>CLK_100M_FPGA_N | input | Free running 100MHz FPGA clock | +| FPGA_RST_L | input | Main Hard Reset (active low) | +| INTERRUPT_L | input | Main Interrupt (active low) | +| ETH_NPU_TX[11:0]_P<br>ETH_NPU_TX[11:0]_N | output | Ethernet Transmit towards the NPU | +| ETH_NPU_RX[11:0]_P<br>ETH_NPU_RX[11:0]_N | input | Ethernet Receive from the NPU | +| SFP_TX[11:0]_P<br>SFP_TX[11:0]_N | output | CPRI 3-8 Transmit | +| SFP_RX[11:0]_P<br>SFP_RX[11:0]_N | input | CPRI 3-8 Receive | +| ETH_REF [3:1]_156P25M_CLK_P<br>ETH_REF [3:1]_156P25M_CLK_N | input | Ethernet reference clocks (156.25MHz) | +| CPRI_REF[4:1]_245P76M_CLK_P<br>CPRI_REF[4:1]_245P76M_CLK_N<br>CPRI_REF4_DUP_245P76M_CLK_P<br>CPRI_REF4_DUP_245P76M_CLK_N | input | CPRI reference clocks (245.76MHz) | +| SFP[13:0]_LOS | input | SFP Loss of signal indication | +| PCIE_TX0_P<br>PCIE_TX0_N | output | PCIe x1 Gen 2.0 Transmit | +| PCIE_RX0_P<br>PCIE_RX0_N | input | PCIe x1 Gen 2.0 Receive | + +| | | | +|--------------------------------------------|-------|------------------------------------------------------------------| +| PCIE_REF_100M_CLK_P<br>PCIE_REF_100M_CLK_N | input | PCIe FT Reference clock (100MHz) | +| DFPGA_PCIE_RST_L | input | PCIe reset (active high) | +| TOD_DFPGA_1PPS | input | One pulse per second signal | +| TOD_250M_CLK_P<br>TOD_250M_CLK_N | input | 1588 clock (250MHz) | +| TOD_IN | input | Time Of Day (seconds) value | +| TOD_CLKI | input | 100Hz clock input used to qualify the Time-of-Day value (TOD_IN) | + +## 4.5 Scalability and flexibility of Radio Signal Processor + +If multiple instances of FPGA radio signal processing functions are required to meet the requirements of a certain deployment scenario for which a single FPGA would not suffice, the modified hardware architecture shown in Figure 12 can be used. This enables scaling of radio signal processing in the FHGW as well as integrating different radio processing capabilities from the same or different implementors. + +Figure 14 shows how the model can be replicated to instantiate multiple FPGAs in a fronthaul gateway to achieve higher processing capability or diverse type of processing. The FPGA instances have the same type of interfaces toward the NPU, CPU and the timing modules. + +![Figure 14: Multi-FPGA Architecture diagram. The diagram shows a system architecture within a large box. At the top, a CPU is connected to a SETS PLL & Timing block via a PTP/1588 Servo control line. The SETS block is connected to a Timing Bus. The Timing Bus is connected to two Radio Signal Processor FPGA blocks. Each FPGA block is connected to an NPU block via PCIe lines. The NPU block is connected to the CPU via a dashed line. The NPU block is also connected to the SETS block via a dashed line. The NPU block has multiple Ethernet ports on the left. The two Radio Signal Processor FPGA blocks are connected to each other via an Internal Ethernet line. Each FPGA block has multiple CPRI Ports toward RU or Ethernet Ports toward O-RU on the right.](2d5da092c79e6796ecc043aa42b2ce00_img.jpg) + +Figure 14: Multi-FPGA Architecture diagram. The diagram shows a system architecture within a large box. At the top, a CPU is connected to a SETS PLL & Timing block via a PTP/1588 Servo control line. The SETS block is connected to a Timing Bus. The Timing Bus is connected to two Radio Signal Processor FPGA blocks. Each FPGA block is connected to an NPU block via PCIe lines. The NPU block is connected to the CPU via a dashed line. The NPU block is also connected to the SETS block via a dashed line. The NPU block has multiple Ethernet ports on the left. The two Radio Signal Processor FPGA blocks are connected to each other via an Internal Ethernet line. Each FPGA block has multiple CPRI Ports toward RU or Ethernet Ports toward O-RU on the right. + +Figure 14: Multi-FPGA Architecture + +## 4.6 External Interface Ports on the FHGW<sub>7-2→8</sub> + +This section describes the external interface ports that are used for the operation of the FHGW<sub>7-2→8</sub>. + +### a. Hardware Requirements + +The following table shows the external ports towards the RU/RRHs provided by FHGW<sub>7-2→8</sub> from the radio signal processor + +**Table 12: External Legacy Port List** + +| Port Name | Feature Description | +|--------------------------|-----------------------------------------| +| CPRI Fronthaul interface | m x 10 Gbps SFP+ transceiver interfaces | + +The ports on connected to NPU directly or through Ethernet PHY device(s) + +**Table 13: External Ethernet Port List** + +| Port Name | Feature Description | +|---------------------|-------------------------------------------| +| Ethernet interfaces | n x 1 Gbps SFP+ transceiver interfaces | +| | p x 10 Gbps SFP+ transceiver interfaces | +| | q x 25 Gbps SFP+ transceiver interfaces | +| | r x 100 Gbps QSP28 transceiver interfaces | + +### ***b. Hardware Design*** + +- QSFP28 case and connector: The QSFP28 case and connector are standard and off-the-shelf components +- SFP+ case and connector: The SFP+ case and connector are standard and off-the-shelf components + +# --- Annex 1: Reference to Open CPRI specification + +1. A reference is made to Annex 2 to Annex 7 of ORAN.WG7.IPC-HRD-Opt8.0-v02.00 [3] or succeeding revisions thereof for the example CPRI reference design in this document. +2. Note: This reference design and example implementation is solely provided as an example configuration and has no implication or bearing on the FHGW implementations and products from other vendors. + +# --- Annex ZZZ : O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN ALLIANCE and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN ALLIANCE that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN ALLIANCE or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases + +where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN ALLIANCE hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN ALLIANCE. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter’s distributors and the use by the Adopter’s customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment + +includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN ALLIANCE on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of O-RAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN ALLIANCE or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN ALLIANCE, and cooperates with O-RAN ALLIANCE and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN ALLIANCE's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN ALLIANCE, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, + +PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED “AS IS” WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN ALLIANCE, which consent may be withheld in O-RAN ALLIANCE’s sole discretion. O-RAN ALLIANCE may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity’s or association’s agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates’ performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN ALLIANCE or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN ALLIANCE or its Members, Contributors or Academic Contributors. + +1 In the event that any provision of this Agreement conflicts with governing law or if any provision is held to +2 be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will +3 be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of +4 this Agreement will remain in full force and effect. + +5 Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of +6 any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or +7 otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or +8 third party beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other +9 instance; rather the same shall be and remain in full force and effect. + +--- + +10 \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/0ccb07777b4c50fe9d082db0be1ace22_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/0ccb07777b4c50fe9d082db0be1ace22_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82b8b6d6fc96c92029b903394d457017fa9dbd3c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/0ccb07777b4c50fe9d082db0be1ace22_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:98f7ebf77e85132d02a045273612cf07a4696dd3eec88ee4c3622f7e3ae632e4 +size 30271 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/17253f7fba745802bbe52a2ca1b37ec4_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/17253f7fba745802bbe52a2ca1b37ec4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a5761b253b42016ca7eebbc5ec753a326561cd13 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/17253f7fba745802bbe52a2ca1b37ec4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0b60b228470f2c03776ca30f5643e802e733256aa42b1ec66bb563ebd04aa9b1 +size 45523 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/1b3371aafafc6e4ecabc1ed56bbb6a90_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/1b3371aafafc6e4ecabc1ed56bbb6a90_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..155693b4a9eab3f616d62febc6467de2ca3ffd76 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/1b3371aafafc6e4ecabc1ed56bbb6a90_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:76843c26bf958a8728f043f318560ec93e58fdd19378898d1eb7d56d8e3c4c7c +size 4520 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/1b678fc5a913eb1046b6c936dfda52a8_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/1b678fc5a913eb1046b6c936dfda52a8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..14d0309baa5696d11b72a6eec8ba838f9cf48766 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/1b678fc5a913eb1046b6c936dfda52a8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ade60ddac651fb87fd2e16a6460d8102b84c02cf759b859c01845a2c12e0403 +size 32281 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/1f8a8104e29e70c9db067814f7612d08_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/1f8a8104e29e70c9db067814f7612d08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3050115da78ab73f5676dbe22dd122b83f7d9a89 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/1f8a8104e29e70c9db067814f7612d08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c6d92abb54500ba4fb4914e67ebc16bc7f34adbc28f5164d20bf5ab6677403d9 +size 36272 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/22c2ae84062e3660ea32773be45bb23d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/22c2ae84062e3660ea32773be45bb23d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aa80560664cc50145825e17dfa3f152e281ed812 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/22c2ae84062e3660ea32773be45bb23d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5087a155f2f18a6020823cd6a7e0d6aa2eea107e5a8faec84db92b16e85e8492 +size 34050 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/2a1f568aae91597243f290c85a491740_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/2a1f568aae91597243f290c85a491740_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..567e759aae0da2fd18d0cddf380445633c92b16b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/2a1f568aae91597243f290c85a491740_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f52950a3f24131eb693b289597821b0a7e2702906f5284c9bf61fde64b39c897 +size 4492 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/3ef78a6be10fae1e4802740afcacfc4a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/3ef78a6be10fae1e4802740afcacfc4a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1244be58e0b2249eb31d6eb7563e1e030117c115 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/3ef78a6be10fae1e4802740afcacfc4a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70aaf3ebfc95e740b20d4306a0c3a43f9bc680e52c3dc27331bf7311c93fde28 +size 45754 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/42b037e260ab397fc6a04774fb441af2_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/42b037e260ab397fc6a04774fb441af2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..22ade5227f4d2b2d746e3d1c51e8528cb6e017fc --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/42b037e260ab397fc6a04774fb441af2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fa17245faf27b7201db364a7fca48e4066bfd6485639da795eddd114e726383a +size 41965 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/524324c873b0cb44a0a30e6b0a4374af_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/524324c873b0cb44a0a30e6b0a4374af_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ef47f11807c12621e4bfa6b862b8b7e826efdec9 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/524324c873b0cb44a0a30e6b0a4374af_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e4a07fb83cab5dfd87bbd450aca6b021bdaf57ad9e3329e51aeda26f3b0e811 +size 39713 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/531a6143943284efbb1ce70117dcf5ec_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/531a6143943284efbb1ce70117dcf5ec_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9e7db0d90cf248aade80d2b000e03ca8f84609f0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/531a6143943284efbb1ce70117dcf5ec_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5a408229fe98b587824ee7661dc8d213a7da954e31f8b3e271900e3913248da1 +size 22736 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/5aff7c8f6276d29507ba67d39ef50bdc_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/5aff7c8f6276d29507ba67d39ef50bdc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..671499dca74b1d32e0ab64d29e60b6f8d2da448c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/5aff7c8f6276d29507ba67d39ef50bdc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5dbe35332294d39366fede1401477a11e26a6eb7cac37971843d13c5568fdda4 +size 4479 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/62fae662886bd0a9d7429e3f5ec6622e_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/62fae662886bd0a9d7429e3f5ec6622e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d7d95941cddeae18c0357e8c0bd779a10888500 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/62fae662886bd0a9d7429e3f5ec6622e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:49fe0a2fdd79526b5929f5f8bb34235237ccd58ed34d518e576be11f10290559 +size 4517 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/7690195c8960bd96043db9d75f74548e_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/7690195c8960bd96043db9d75f74548e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6856adc3151754a7ba6d5c2291373aadb98923ce --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/7690195c8960bd96043db9d75f74548e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e6b47c14561b46ed3f0a1cccab328824ed3deeb602b6235675a61c272844dbf7 +size 24732 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/7d2aa3aed8874d2b88ee504e9bb097fe_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/7d2aa3aed8874d2b88ee504e9bb097fe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7c57b48a9505a7988add9b1d52e698ab2ad2cb65 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/7d2aa3aed8874d2b88ee504e9bb097fe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1030a162d5e7b007a09ce70452b4aec55349b43171d2b817c980e4e849ab6a19 +size 27978 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/7e7d27b9422a016de486d2896481c558_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/7e7d27b9422a016de486d2896481c558_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cd9c4b6e4fc7daccadff8ff8692d64c1431c00c9 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/7e7d27b9422a016de486d2896481c558_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8c106f74366a5b502551d74f1f04ed240688e52d34751b7b441f02da6d6a1d1d +size 34001 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/80c33f22bb32aee93289e3e5a1a04d1d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/80c33f22bb32aee93289e3e5a1a04d1d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..90bb003a3b55570f3ae5045e4067603751ec5997 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/80c33f22bb32aee93289e3e5a1a04d1d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a016cf12577bbbcf889df92f677fdf36a7db12f383b958a8d48e4eb3427c7bd1 +size 29188 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/8234c65fdf5a09f7652f65d9f4982ad8_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/8234c65fdf5a09f7652f65d9f4982ad8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b68067b4677f0da38a0592099e44b76c964844b5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/8234c65fdf5a09f7652f65d9f4982ad8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:80c47fdcd044a63dd4ca4b00618fd623818e1bda232a025ea4682da779638472 +size 16384 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/87e2ff7a747555c9aa45f4136188bb94_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/87e2ff7a747555c9aa45f4136188bb94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f87cfae8379ad05f07acb84db9668dc0df245e91 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/87e2ff7a747555c9aa45f4136188bb94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ae3e87355997dcaa9f0d550d0a4d16547caf577ba39120a05d221fbc1999c87 +size 4531 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/8b45f6d8d635b4fa0babce326807f284_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/8b45f6d8d635b4fa0babce326807f284_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9469477783e2942d1848960abdc145b2f6b17243 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/8b45f6d8d635b4fa0babce326807f284_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:94dc0c83b71aaa4ffd9b8de5833899d4c0fbce4ae1ff7d2fc015791beaf8aa28 +size 28470 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/8fc8e2925dd061c737741809b41656b5_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/8fc8e2925dd061c737741809b41656b5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f1717a039abbfd1643b7d72230d28f209df0940f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/8fc8e2925dd061c737741809b41656b5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:144fa4cc6612eca0a9e7a38461dc62de0191dbdfe293cd57512b0fe6732e8841 +size 34989 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/920f3765f97dd46f52d1a4b6e8e085d2_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/920f3765f97dd46f52d1a4b6e8e085d2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a5ab23d1d42cc8a360050811081ef9b2e4aa842e --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/920f3765f97dd46f52d1a4b6e8e085d2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7c47b245ef8ed6b6f2e9add6dd335d50dfa8571b8fce9528bd2869cc7ecabb57 +size 50910 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/9579a48da2c9c4fff70b893e3730ae35_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/9579a48da2c9c4fff70b893e3730ae35_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a1e0cb39fcb0d3ddbe79c3f87e444751bc15a315 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/9579a48da2c9c4fff70b893e3730ae35_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab42cf044ad231d80031deeb912fa6d09845fd28ebc7bbadbd1fa8ae80063ddc +size 24058 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/a34185e0d7d74f3c8e0ed043775f596d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/a34185e0d7d74f3c8e0ed043775f596d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..89b98bb3084fbbd77ace99ece4e4443e65245354 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/a34185e0d7d74f3c8e0ed043775f596d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2960b4ee779667c302a9f16ee1ddbc7145ec879bb3cc859375caca944cc83eb5 +size 32402 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/abc0d004355b24e69e16352e115cc67c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/abc0d004355b24e69e16352e115cc67c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..75c3069dd2617c92a8f0c4944027b21812fc46c6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/abc0d004355b24e69e16352e115cc67c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c0d1d350b617901e45f50f4ac426fec4a1dc3480f9a82121895f12a3c6527740 +size 4494 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/b1359f8315a154b303a21dbaffa1fc27_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/b1359f8315a154b303a21dbaffa1fc27_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..723ba36a60438be8e8d5f8469047d514bec8f874 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/b1359f8315a154b303a21dbaffa1fc27_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:71bbbe652461da5f6420bba8c1f8f0c6382692ad8267f7ec827c1c435965624e +size 4462 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/b2ff5da9c9469be2ae8486181e3ab211_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/b2ff5da9c9469be2ae8486181e3ab211_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f456a61f3009b784b48ba5b0feb9842384be1e1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/b2ff5da9c9469be2ae8486181e3ab211_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b3f456fa2e98ad349932002d718d411ced1b77191b2c32ed23db8a1d70a19960 +size 27645 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/bfda6380216d4064380ea0eab297d80f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/bfda6380216d4064380ea0eab297d80f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..028ed9ad8feb089166bcf1d5387d682f2697c976 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/bfda6380216d4064380ea0eab297d80f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:10c520b9ddb576000dce59e59f9fdcd8f56334a5c12effbe561ecb12e24088ad +size 30523 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/c6addcfe1c47c242a7f08b0bda7673f0_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/c6addcfe1c47c242a7f08b0bda7673f0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d8e0f35c90c58cb5dc668cd7d6709e78bb7b1b6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/c6addcfe1c47c242a7f08b0bda7673f0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fa8583147edfb9c9953cd866acc0852a68a4340ee0af67004ff559dff0cf4006 +size 29687 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/cfe2ecc03d5304a23e5c17fc8fbe1b25_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/cfe2ecc03d5304a23e5c17fc8fbe1b25_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ee4fe2650273d6b414401530deb860e4da1d96b8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/cfe2ecc03d5304a23e5c17fc8fbe1b25_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3fc805c3bcbff5991a4bb77dcad4e7b95004031f35e331453f4d751eaa090578 +size 31798 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/d4e2e9b7ddec74c65a936c494bd18f8e_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/d4e2e9b7ddec74c65a936c494bd18f8e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d40ce5f7da2ce212d456e3dab9cd48dc437bbdef --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/d4e2e9b7ddec74c65a936c494bd18f8e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7f1cfe33858c7d1ecaf45e39708c01216435a788ca04ecf3f1d692c1c77ac12a +size 46222 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/dd590e7a556655956f9a46f8a7105d44_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/dd590e7a556655956f9a46f8a7105d44_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2bba95c84392f6e16d44c4d3cae22386b9d1de06 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/dd590e7a556655956f9a46f8a7105d44_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6c3b1cc0e61a0a7aede0bacc192260b5f6403a6924c5fa998b8259de73bc3137 +size 35610 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/de505ea9fd2bbe1a3d84d4a9fd6dbdd3_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/de505ea9fd2bbe1a3d84d4a9fd6dbdd3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..875d393c8a5a80503ff59a9b9db580ada20c110f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/de505ea9fd2bbe1a3d84d4a9fd6dbdd3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3c224ad2f2bfbb7e69d1c224ac856e950c19ac05a190902b0cf2fa2f9faf17f0 +size 4492 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/e30f911a9db20da291ea8653e125c407_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/e30f911a9db20da291ea8653e125c407_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5be4638b6c53c9ffd698c5d98a7231e2c7ff1dc6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/e30f911a9db20da291ea8653e125c407_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:759c429bb1111dcfd2f435a434b23acace763e4f6d00e61c01c1912a721c0fc3 +size 27284 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/e5b6fbacd157b8df16039ec62378e49c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/e5b6fbacd157b8df16039ec62378e49c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2865b1ac3ad8723dac22401d5075dcbd3293e7a5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/e5b6fbacd157b8df16039ec62378e49c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d4f86d702abc4731f9ce6a3d7a33913ea287d05244833bb3f7910a3b96355429 +size 25992 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/edccd911136952a946a4d8d8d073f457_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/edccd911136952a946a4d8d8d073f457_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a8f2982a2fcfe942ca37cb9c5ad4f0049ce8502d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/edccd911136952a946a4d8d8d073f457_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d07c91e002e29b322ec1d08907dd260a5aadd62233fcaeb62f6f2b4a7cbeaa5 +size 4420 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/f07c05f2fc9c1fc009aa4f945c6bc737_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/f07c05f2fc9c1fc009aa4f945c6bc737_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..af514a5423c63c975fd65507b541ae721270293d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/f07c05f2fc9c1fc009aa4f945c6bc737_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09ba062d6c6273845174f34001fa6fe8000e929dc9b9e754d0ac66639a0edeb0 +size 24407 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/f0e001951d41bd82bedcaff7832f8c37_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/f0e001951d41bd82bedcaff7832f8c37_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f368e0d1c8a485630246e63e60a1bc327a35b697 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/f0e001951d41bd82bedcaff7832f8c37_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3849f68d6e1f1fe0202ad23c959c86f37d5c266bba8e074684560d4f5212d7ed +size 7934 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/f2a7a793e37e98805b036783185e4013_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/f2a7a793e37e98805b036783185e4013_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ee5939c8283db209bf97ca0a6a3cc55067c71eff --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/f2a7a793e37e98805b036783185e4013_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5a752dbc07cbd5c9f81870917089b1663d4bd1523ce17fae4c79456170eea3c0 +size 7937 diff --git a/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/raw.md b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..b4c2ee7316bbcf313d6db74184f1b7a144bc8e8d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HAR.0-v03.00/raw.md @@ -0,0 +1,1704 @@ + + +# **O-RAN White Box Hardware Working Group Indoor Picocell Hardware Architecture and Requirement (FR1 Only) Specification** --- + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +1 + +## Revision History + +| Date | Revision | Author | Description | +|------------|----------|--------|-------------------------| +| 02/20/2020 | V01.00 | WG7 | First Published Version | +| 10/18/2023 | V02.00 | WG7 | Second Version | +| 07/16/2024 | V03.00 | WG7 | Third Version | + +2 + +# Contents + +| | | | | +|----|-----------------------------------------------------------------------------------------|----|--| +| 1 | | | | +| 2 | Revision History..... | 2 | | +| 3 | Chapter 1   Introductory Material..... | 7 | | +| 4 | 1.1       Scope ..... | 7 | | +| 5 | 1.2       References ..... | 7 | | +| 6 | 1.3       Definitions and Abbreviations..... | 8 | | +| 7 | 1.3.1       Definitions..... | 8 | | +| 8 | 1.3.2       Abbreviations..... | 8 | | +| 9 | Chapter 2   Deployment Scenarios and White Box Base Station Architecture ..... | 11 | | +| 10 | 2.1       Deployment Scenarios ..... | 11 | | +| 11 | 2.2       White Box Base Station Architecture ..... | 11 | | +| 12 | 2.2.1       Split RAN Architecture..... | 12 | | +| 13 | 2.2.2       Integrated gNB-DU Architecture ..... | 14 | | +| 14 | 2.2.3       All-In-One Base Station Architecture ..... | 14 | | +| 15 | Chapter 3   White Box Hardware Architecture ..... | 15 | | +| 16 | 3.1       O-CU Hardware Architecture..... | 15 | | +| 17 | 3.1.1       O-CU Architecture Diagram ..... | 15 | | +| 18 | 3.1.2       O-CU Functional Module Description ..... | 15 | | +| 19 | 3.1.3       O-CU Interfaces ..... | 15 | | +| 20 | 3.2       O-DU <sub>7-2</sub> Hardware Architecture ..... | 15 | | +| 21 | 3.2.1       O-DU <sub>7-2</sub> Architecture Diagram ..... | 16 | | +| 22 | 3.2.2       O-DU <sub>7-2</sub> Functional Module Description ..... | 16 | | +| 23 | 3.2.3       O-DU <sub>7-2</sub> Interfaces ..... | 17 | | +| 24 | 3.3       O-DU <sub>6</sub> Hardware Architecture ..... | 18 | | +| 25 | 3.3.1       O-DU <sub>6</sub> Architecture Diagram..... | 18 | | +| 26 | 3.3.2       O-DU <sub>6</sub> Functional Module Description ..... | 18 | | +| 27 | 3.3.3       O-DU <sub>6</sub> Interfaces..... | 18 | | +| 28 | 3.4       O-DU <sub>8</sub> Hardware Architecture..... | 18 | | +| 29 | 3.4.1       O-DU <sub>8</sub> Architecture Diagram..... | 19 | | +| 30 | 3.4.2       O-DU <sub>8</sub> Functional Module Description ..... | 19 | | +| 31 | 3.4.3       O-DU <sub>8</sub> Interfaces ..... | 20 | | +| 32 | 3.5       FHGW <sub>7-2</sub> - Option 7-2 to Option 7-2 Hardware Architecture..... | 20 | | +| 33 | 3.5.1       FHGW <sub>7-2</sub> Architecture Diagram..... | 20 | | +| 34 | 3.5.2       FHGW <sub>7-2</sub> Functional Module Description..... | 20 | | +| 35 | 3.6       FHGW <sub>6</sub> - Option 6 to Option 6 Hardware Architecture ..... | 21 | | +| 36 | 3.7       FHGW <sub>7-2->8</sub> - Option 7-2 to Option 8 Hardware Architecture..... | 21 | | +| 37 | 3.7.1       FHGW <sub>7-2->8</sub> Architecture Diagram ..... | 21 | | +| 38 | 3.7.2       FHGW <sub>7-2->8</sub> Functional Module Description..... | 22 | | +| 39 | 3.8       FHGW <sub>8</sub> - Option 8 to Option 8 Hardware Architecture ..... | 22 | | +| 40 | 3.8.1       FHGW <sub>8</sub> Architecture Diagram..... | 22 | | +| 41 | 3.8.2       FHGW <sub>8</sub> Functional Module Description ..... | 23 | | +| 42 | 3.9       O-RU <sub>7-2</sub> Hardware Architecture..... | 24 | | +| 43 | 3.9.1       O-RU <sub>7-2</sub> Architecture Diagram..... | 24 | | +| 44 | 3.9.2       O-RU <sub>7-2</sub> Functional Module Description..... | 24 | | +| 45 | 3.10       O-RU <sub>6</sub> Hardware Architecture..... | 25 | | +| 46 | 3.10.1       O-RU <sub>6</sub> Architecture Diagram..... | 25 | | +| 47 | 3.10.2       O-RU <sub>6</sub> Functional Module Description..... | 25 | | +| 48 | 3.11       O-RU <sub>8</sub> Hardware Architecture ..... | 26 | | + +| | | | | +|----|-----------|-------------------------------------------------------------|----| +| 1 | 3.11.1 | O-RU <sub>8</sub> Architecture Diagram ..... | 26 | +| 2 | 3.11.2 | O-RU <sub>8</sub> Functional Module Description..... | 27 | +| 3 | 3.12 | Integrated gNB-DU Hardware Architecture ..... | 27 | +| 4 | 3.12.1 | Integrated gNB-DU Architecture Diagram ..... | 28 | +| 5 | 3.12.2 | Integrated gNB-DU Function Module Description ..... | 28 | +| 6 | 3.13 | AIO White Box Hardware Architecture ..... | 29 | +| 7 | 3.13.1 | AIO Architecture Diagram..... | 29 | +| 8 | 3.13.2 | AIO Functional Module Description..... | 29 | +| 9 | 3.13.3 | AIO Interfaces..... | 30 | +| 10 | Chapter 4 | White Box Hardware Requirements ..... | 31 | +| 11 | 4.1 | O-CU Requirements ..... | 31 | +| 12 | 4.1.1 | O-CU Performance..... | 31 | +| 13 | 4.1.2 | O-CU Interfaces ..... | 32 | +| 14 | 4.1.3 | O-CU Environmental and EMC..... | 32 | +| 15 | 4.1.4 | O-CU Mechanical, Thermal and Power..... | 32 | +| 16 | 4.2 | O-DU <sub>x</sub> Common Requirements ..... | 33 | +| 17 | 4.2.1 | O-DU <sub>x</sub> Performance ..... | 34 | +| 18 | 4.2.2 | O-DU <sub>x</sub> Interfaces..... | 35 | +| 19 | 4.2.3 | O-DU <sub>x</sub> Environmental and EMC ..... | 35 | +| 20 | 4.2.4 | O-DU <sub>x</sub> Mechanical, Thermal and Power ..... | 35 | +| 21 | 4.3 | O-DU <sub>x</sub> Split Option Specific Requirements ..... | 36 | +| 22 | 4.3.1 | O-DU <sub>7-2</sub> Specific Requirements ..... | 36 | +| 23 | 4.3.2 | O-DU <sub>6</sub> Specific Requirements ..... | 37 | +| 24 | 4.3.3 | O-DU <sub>8</sub> Specific Requirements ..... | 37 | +| 25 | 4.4 | O-RU <sub>x</sub> Common Requirements ..... | 37 | +| 26 | 4.4.1 | O-RU <sub>x</sub> Performance ..... | 37 | +| 27 | 4.4.2 | O-RU <sub>x</sub> Interfaces..... | 39 | +| 28 | 4.4.3 | O-RU <sub>x</sub> Environmental and EMC..... | 39 | +| 29 | 4.4.4 | O-RU <sub>x</sub> Mechanical, Thermal and Power..... | 39 | +| 30 | 4.5 | O-RU <sub>x</sub> Split Option Specific Requirements..... | 40 | +| 31 | 4.5.1 | O-RU <sub>7-2</sub> Specific Requirements ..... | 40 | +| 32 | 4.5.2 | O-RU <sub>6</sub> Specific Requirements ..... | 40 | +| 33 | 4.5.3 | O-RU <sub>8</sub> Specific Requirements ..... | 41 | +| 34 | 4.6 | FHGW <sub>x</sub> – Common Requirements ..... | 41 | +| 35 | 4.6.1 | FHGW <sub>x</sub> Performance ..... | 41 | +| 36 | 4.6.2 | FHGW <sub>x</sub> Interfaces..... | 41 | +| 37 | 4.6.3 | FHGW <sub>x</sub> Environmental, EMCs..... | 42 | +| 38 | 4.6.4 | FHGW <sub>x</sub> Mechanical, Thermal and Power..... | 42 | +| 39 | 4.7 | FHGW <sub>x</sub> – Split Option Specific Requirements..... | 43 | +| 40 | 4.7.1 | FHGW <sub>7-2</sub> Specific Requirements..... | 43 | +| 41 | 4.7.2 | FHGW <sub>7-2->8</sub> Specific Requirements..... | 43 | +| 42 | 4.7.3 | FHGW <sub>8</sub> Specific Requirements..... | 43 | +| 43 | 4.8 | Integrated gNB-DU Requirements ..... | 43 | +| 44 | 4.8.1 | Integrated gNB-DU Performance..... | 44 | +| 45 | 4.8.2 | Integrated gNB-DU Interfaces ..... | 45 | +| 46 | 4.8.3 | Integrated gNB-DU Environmental, EMC..... | 45 | +| 47 | 4.8.4 | Integrated gNB-DU Mechanical, Thermal and Power ..... | 46 | +| 48 | 4.9 | AIO White Box Hardware Requirements ..... | 47 | +| 49 | 4.9.1 | AIO Performance ..... | 47 | +| 50 | 4.9.2 | AIO Interfaces..... | 48 | +| 51 | 4.9.3 | AIO Environmental and EMC..... | 49 | + +| | | | +|-------|-----------------------------------------|----| +| 4.9.4 | AIO Mechanical, Thermal and Power ..... | 49 | +|-------|-----------------------------------------|----| + +## Tables + +| | | | +|------------|---------------------------------------------------------------------|----| +| Table 4-1 | :O-CU Performance Requirements ..... | 31 | +| Table 4-2 | :O-CU Interface Requirements ..... | 32 | +| Table 4-3 | :O-CU EMC Requirements ..... | 32 | +| Table 4-4 | :O-CU Mechanical Requirements ..... | 32 | +| Table 4-5 | :O-CU Thermal Requirements ..... | 33 | +| Table 4-6 | :O-CU Power Requirements ..... | 33 | +| Table 4-7 | :O-DU <sub>x</sub> Performance Requirements ..... | 34 | +| Table 4-8 | :O-DU <sub>x</sub> Interface Requirements ..... | 35 | +| Table 4-9 | :O-DU <sub>x</sub> EMC Requirements ..... | 35 | +| Table 4-10 | :O-DU <sub>x</sub> Mechanical Requirements ..... | 35 | +| Table 4-11 | :O-DU <sub>x</sub> Thermal Requirements ..... | 36 | +| Table 4-12 | :O-DU <sub>x</sub> Power Requirements ..... | 36 | +| Table 4-13 | :O-DU <sub>7-2</sub> Specific Requirements ..... | 36 | +| Table 4-14 | :O-DU <sub>6</sub> Specific Requirements ..... | 37 | +| Table 4-15 | :O-DU <sub>8</sub> Specific Requirements ..... | 37 | +| Table 4-16 | :O-RU <sub>x</sub> Performance Requirements ..... | 38 | +| Table 4-17 | :O-RU <sub>x</sub> Interface Requirements ..... | 39 | +| Table 4-18 | :O-RU <sub>x</sub> Environmental and EMC Requirements ..... | 39 | +| Table 4-19 | :O-RU <sub>x</sub> Mechanical, Thermal and Power Requirements ..... | 39 | +| Table 4-20 | :FHGW <sub>x</sub> Performance Requirements ..... | 41 | +| Table 4-21 | :FHGW <sub>x</sub> Interface Requirements ..... | 41 | +| Table 4-22 | :FHGW <sub>x</sub> EMC Requirements ..... | 42 | +| Table 4-23 | :FHGW <sub>x</sub> Mechanical, Thermal and Power Requirements ..... | 42 | +| Table 4-24 | :Integrated gNB-DU Performance Requirements ..... | 44 | +| Table 4-25 | :Integrated gNB-DU Interface Requirements ..... | 45 | +| Table 4-26 | :Integrated gNB-DU Environmental and EMC Requirements ..... | 45 | +| Table 4-27 | :Integrated gNB-DU Mechanical, Thermal and Power Requirements ..... | 46 | +| Table 4-28 | :AIO Whitebox Performance Requirements ..... | 47 | +| Table 4-29 | :AIO Whitebox Interface Requirements ..... | 48 | +| Table 4-30 | :AIO EMC Requirements ..... | 49 | +| Table 4-31 | :AIO Mechanical Requirements ..... | 49 | +| Table 4-32 | :Thermal Requirements ..... | 49 | +| Table 4-33 | :AIO Whitebox Power Requirements ..... | 50 | + +## Figures + +| | | | +|------------|----------------------------------------------------|----| +| Figure 2-1 | :Indoor Split Architecture ..... | 11 | +| Figure 2-2 | :Indoor Integrated Architecture ..... | 12 | +| Figure 2-3 | :Indoor All-In-One Architecture ..... | 12 | +| Figure 2-4 | :Option 6 to Option 6 Split Architecture ..... | 12 | +| Figure 2-5 | :Option 7-2 to Option 7-2 Split Architecture ..... | 13 | + +| | | | +|----|-----------------------------------------------------------------------------|----| +| 1 | Figure 2-6: Option 7-2 to Option 8 Split Architecture ..... | 13 | +| 2 | Figure 2-7: Option 8 to Option 8 Split Architecture ..... | 14 | +| 3 | Figure 2-8: Integrated gNB-DU Architecture ..... | 14 | +| 4 | Figure 2-9: All-In-One Base Station Architecture ..... | 14 | +| 5 | Figure 3-1: O-CU White Box Hardware Block Diagram..... | 15 | +| 6 | Figure 3-2: O-DU <sub>7-2</sub> with Split Physical Function..... | 16 | +| 7 | Figure 3-3: O-DU <sub>7-2</sub> Functional Block and Interface Diagram..... | 17 | +| 8 | Figure 3-4: O-DU <sub>6</sub> Architecture Diagram ..... | 18 | +| 9 | Figure 3-5: O-DU <sub>8</sub> Architecture Diagram ..... | 19 | +| 10 | Figure 3-6: O-DU <sub>8</sub> Functional Block and Interface Diagram ..... | 19 | +| 11 | Figure 3-7: FHGW <sub>7-2</sub> Architecture Diagram ..... | 20 | +| 12 | Figure 3-8: FHGW <sub>7-2</sub> Functional Module Diagram..... | 21 | +| 13 | Figure 3-9: FHGW <sub>7-2->8</sub> Architecture Diagram..... | 21 | +| 14 | Figure 3-10: FHGW <sub>7-2->8</sub> Functional Module Diagram ..... | 22 | +| 15 | Figure 3-11: FHGW <sub>8</sub> Architecture Diagram ..... | 23 | +| 16 | Figure 3-12: FHGW <sub>8</sub> Functional Module Diagram ..... | 23 | +| 17 | Figure 3-13: O-RU <sub>7-2</sub> Architecture Diagram ..... | 24 | +| 18 | Figure 3-14: O-RU <sub>7-2</sub> Functional Module Diagram..... | 25 | +| 19 | Figure 3-15: O-RU <sub>6</sub> Architecture Diagram ..... | 25 | +| 20 | Figure 3-16: O-RU <sub>6</sub> Functional Module Diagram..... | 26 | +| 21 | Figure 3-17: O-RU <sub>8</sub> Architecture Diagram. .... | 27 | +| 22 | Figure 3-18: O-RU <sub>8</sub> Functional Module Diagram ..... | 27 | +| 23 | Figure 3-19: Integrated gNB-DU Architecture Diagram..... | 28 | +| 24 | Figure 3-20: Integrated gNB-DU Functional Module Diagram..... | 28 | +| 25 | Figure 3-21: AIO White box Architecture Diagram ..... | 29 | +| 26 | | | +| 27 | | | + +# Chapter 1      Introductory Material + +## 1.1      Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG7 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x    the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y    the second digit is incremented when editorial only changes have been incorporated in the document. +- z    the third digit included only in working versions of the document indicating incremental changes during the editing process. This variable is for internal WG7 use only. + +The present document specifies system requirements and high-level architecture for the Indoor Picocell deployment scenario case as specified in the Deployment Scenarios and Base Station Classes document [1]. + +## 1.2      References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- [1]    ORAN.WG7.DSC.0-v05.00 Technical Specification, ‘Deployment Scenarios and Base Station Classes for White Box Hardware’. +- [2]    3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [3]    3GPP TR 38.104: "NR; Base Station (BS) radio transmission and reception". +- [4]    ORAN-WG4.CUS.0-v01.00 Technical Specification, ‘O-RAN Fronthaul Working Group Control, User and Synchronization Plane Specification’. +- [5]    CPRI Specification V7.0 (2015-10-09) Interface Specification, ‘Common Public Radio Interface (CPRI). +- [6]    Small Cell Forum nFAPI Specification (Not yet publicly available, however it will be available as part of an O-RAN approved WG7 reference design specification) +- [7]    3GPP TS 38.113: “NR: Base Station (BS) Electromagnetic Compatibility (EMC) +- [8]    O-RAN.SuFG.CE-v01.00, O-RAN SuFG, “Circular economy guidelines on network equipment – Technical Report”, - v01.00. + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [2] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in [2]. For the base station classes of Pico, Micro and Macro, the definitions are given in 3GPP TR 38.104 [3]. + +**All-In-One architecture:** In the all-in-one architecture, the O-RU, O-DU and O-CU are implemented on one platform. There is no need for neither fronthaul interface between O-RU and O-DU nor F1 interface between O-DU and O-CU. + +**Carrier Frequency:** Center frequency of the cell. + +**F1 interface:** The open interface between O-CU and O-DU<sub>x</sub>. + +**Integrated architecture:** In the integrated architecture, the O-RU<sub>x</sub> and O-DU<sub>x</sub> are implemented on one platform. Each O-RU<sub>x</sub> and RF front end is associated with one O-DU<sub>x</sub>. They are then aggregated to O-CU and connected by F1 interface. + +**Split architecture:** The O-RU<sub>x</sub> and O-DU<sub>x</sub> are physically separated from one another in this architecture. A switch may aggregate multiple O-RU<sub>x</sub> (s) to one O-DU<sub>x</sub>. O-DU<sub>x</sub>, switch and O-RU<sub>x</sub> (s) are connected by the fronthaul interface as defined in WG4. + +**Transmission Reception Point (TRxP):** Antenna array with one or more antenna elements available to the network located at a specific geographical location for a specific area. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in [2] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, as in [2]. + +| | | +|------|------------------------------------------------------------------------------------| +| 7-2 | Fronthaul interface split option as defined by O-RAN WG4, also referred to as 7-2x | +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth-Generation Mobile Communications | +| 5GC | 5G Core | +| ACS | Adjacent Channel Selectivity | +| ADC | Analog to Digital Converter | +| AIO | All-In-One | +| ASIC | Application Specific Integrated Circuit | +| ATA | Advanced Technology Attachment | +| BB | Baseband | +| BPSK | Binary Phase Shift Keying | +| BS | Base Station | +| CFR | Crest Factor Reduction | +| CU | Centralized Unit as defined by 3GPP | +| DAC | Digital to Analog Converter | +| DDC | Digital Down Conversion | +| DDR | Double Data Rate | +| DL | Downlink | + +| | | | +|----|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | DPD | Digital Pre-Distortion | +| 2 | DSP | Digital Signal Processor | +| 3 | DU | Distributed Unit as defined by 3GPP | +| 4 | DUC | Digital Up Conversion | +| 5 | EMC | ElectroMagnetic Compatibility | +| 6 | EVM | Error Vector Magnitude | +| 7 | FFT | Fast Fourier Transform | +| 8 | FH | Fronthaul | +| 9 | FHGW | Fronthaul Gateway | +| 10 | FHGW <sub>x</sub> | Fronthaul gateway with no FH protocol translation, supporting an O-DU <sub>x</sub> with split option x and an O-RU <sub>x</sub> with split option x, with currently available options 6→6, 7-2→7-2 and 8→8 | +| 11 | | | +| 12 | | | +| 13 | FHGW <sub>x→y</sub> | Fronthaul Gateway that can translate FH protocol from an O-DU <sub>x</sub> with split option x to an O-RU <sub>y</sub> with split option y, with currently available option 7-2→8. | +| 14 | | | +| 15 | FPGA | Field Programmable Gate Array | +| 16 | GbE | Gigabit Ethernet | +| 17 | GPP | General Purpose Processor | +| 18 | IEEE | Institute of Electrical and Electronics Engineers | +| 19 | IMD | InterModulation Distortion | +| 20 | I/O | Input/Output | +| 21 | JTAG | Joint Test Action Group | +| 22 | L1 | Layer 1, also referred as PHY, also known as Physical Layer of Open System Interconnection (OSI) model | +| 23 | | | +| 24 | L2 | Layer 2, also referred to as Data Link layer in OSI model | +| 25 | L3 | Layer 3, also referred to as Network Layer in OSI model | +| 26 | LED | Light Emitting Diode | +| 27 | LTE | Long Term Evolution | +| 28 | MAC | Media Access Control | +| 29 | MIMO | Multiple Input Multiple Output | +| 30 | MCP | Multi-Chip Package | +| 31 | MU-MIMO | Multiple User MIMO | +| 32 | NG | Next Generation | +| 33 | NR | New Radio | +| 34 | OAM | Operations, Administrations and Maintenance | +| 35 | O-CU | O-RAN Centralized Unit as defined by O-RAN | +| 36 | O-DU <sub>x</sub> | A specific O-RAN Distributed Unit having fronthaul split option x where x may be 6, 7-2 (as defined by WG4) or 8 | +| 37 | | | +| 38 | O-RU <sub>x</sub> | A specific O-RAN Radio Unit having fronthaul split option x, where x is 6, 7-2 (as defined by WG4) or 8, and which is used in a configuration where the fronthaul interface is the same at the O-DU <sub>x</sub> | +| 39 | | | +| 40 | | | +| 41 | PCIe | Peripheral Component Interface Express | +| 42 | PDCP | Packet Data Convergence Protocol | +| 43 | PHY | Physical Layer, also referred as L1 | +| 44 | PLL | Phase Locked Loop | +| 45 | POE | Power over Ethernet | +| 46 | QAM | Quadrature Amplitude Modulation | +| 47 | QPSK | Quadrature Phase Shift Keying | +| 48 | RAN | Radio Access Network | + +| | | | +|----|------|-----------------------------------------| +| 1 | RF | Radio Frequency | +| 2 | RLC | Radio Link Controller | +| 3 | RRC | Radio Resource Controller | +| 4 | RU | Radio Unit as defined by 3GPP | +| 5 | RX | Receiver | +| 6 | SDU | Service Data Unit | +| 7 | SFP | Small Form-factor Pluggable | +| 8 | SFP+ | Small Form-factor Pluggable Transceiver | +| 9 | SoC | System on Chip | +| 10 | SPI | Serial Peripheral Interface | +| 11 | TR | Technical Report | +| 12 | TS | Technical Specification | +| 13 | TX | Transmitter | +| 14 | UL | Uplink | +| 15 | USB | Universal Serial Bus | +| 16 | WG | Working Group | +| 17 | | | +| 18 | | | + +# Chapter 2 Deployment Scenarios and White Box Base Station Architecture + +This chapter consists of two parts: the deployment scenario and the white box architecture. The deployment scenarios outline more specific functional requirements of the base station. All the reference designs shall meet these requirements in order to comply with O-RAN white box standard. In the white box hardware architecture section, it describes the overall gNB hardware architecture and function partition that meet the design requirements. The details on each of these topics are described in the following sections. + +## 2.1 Deployment Scenarios + +The indoor picocell is the targeted deployment scenario of this specification. The requirements of the indoor picocell base station are listed in the white box Deployment Scenarios and Base Station Classes document [1]. Some of the key requirements described in that document are highlighted here. + +- Cell type: Indoor +- Carrier Frequency Band: FR1 +- Frequency Bandwidth: Up to 100 MHz +- Inter site distance: 20 meters +- Antennas: 2Tx2Rx; 4Tx4Rx +- Fronthaul Type: O-RAN FH (WG4), 3GPP Option 6 and 3GPP Option 8 + +## 2.2 White Box Base Station Architecture + +In general, the base station hardware architecture can be classified by using different criteria. The physical partition method is adopted by O-RAN; hence, the base station architecture is divided into three categories namely split, integrated, and all-in-one. In split architecture, the fronthaul interface determines the gNB functions location. Here we refer to the two partitions as O-DU<sub>x</sub> and O-RU<sub>x</sub>; where the “x” is split option number. In case the O-RAN WG4 defined fronthaul interface is used, these two partitions are called O-DU<sub>7-2</sub> and O-RU<sub>7-2</sub>. For a more complete description of the terminology used, refer to the Deployment Scenarios and Base Station Classes Document [1]. + +The split architecture is shown in Figure 2-1. A Fronthaul Gateway (FHGW) is an optional device between the O-DU<sub>x</sub> and O-RU<sub>x</sub> to aggregate multiple radio units together. Within this specification, a Back End fronthaul interface is defined as the connection between the FHGW<sub>x</sub> and the O-DU<sub>x</sub>, while the Font End fronthaul interface is defined as the connection between the FHGW<sub>x</sub> and the O-RU<sub>x</sub>. With split architectures, one may choose to have O-CU and O-DU<sub>x</sub> as either co-located or shared configuration with respect to hardware. + +![Figure 2-1: Indoor Split Architecture diagram. It shows a dashed box containing O-CU and O-DU_x connected by a double-headed arrow. Below this box is the text 'O-CU & O-DU may be integrated into one Whitebox'. To the right of this box is O-RU_x, connected to the dashed box by a double-headed arrow labeled 'Front Haul Interface'.](531a6143943284efbb1ce70117dcf5ec_img.jpg) + +``` + +graph LR + subgraph Whitebox [O-CU & O-DU may be integrated into one Whitebox] + OCU[O-CU] <--> ODUX[O-DUx] + end + Whitebox <-->|Front Haul Interface| ORUx[O-RUx] + +``` + +Figure 2-1: Indoor Split Architecture diagram. It shows a dashed box containing O-CU and O-DU\_x connected by a double-headed arrow. Below this box is the text 'O-CU & O-DU may be integrated into one Whitebox'. To the right of this box is O-RU\_x, connected to the dashed box by a double-headed arrow labeled 'Front Haul Interface'. + +Figure 2-1: Indoor Split Architecture + +For integrated base station architecture, the O-DU is integrated with the O-RU into one box. Figure 2-2 shows the integrated architecture. + +![Figure 2-2: Indoor Integrated Architecture diagram. It shows an O-CU (dashed box) connected via an F1 Interface to a Switch/Router. The Switch/Router is then connected via an F1 Interface to multiple O-DU&O-RU (dashed boxes).](7690195c8960bd96043db9d75f74548e_img.jpg) + +``` + +graph LR + OCU[O-CU] <-->|F1 Interface| SR[Switch/Router] + SR <-->|F1 Interface| ODU1[O-DU&O-RU] + SR <-->|F1 Interface| ODU2[O-DU&O-RU] + SR <-->|F1 Interface| ODU3[O-DU&O-RU] + +``` + +Figure 2-2: Indoor Integrated Architecture diagram. It shows an O-CU (dashed box) connected via an F1 Interface to a Switch/Router. The Switch/Router is then connected via an F1 Interface to multiple O-DU&O-RU (dashed boxes). + +**Figure 2-2: Indoor Integrated Architecture** + +The all-in-one architecture is shown in Figure 2-3. This architecture is defined as where O-CU, O-DU<sub>x</sub> and O-RU<sub>x</sub> are physically located in one hardware box. + +![Figure 2-3: Indoor All-In-One Architecture diagram. It shows a single dashed box labeled 'BB & RF'.](f2a7a793e37e98805b036783185e4013_img.jpg) + +``` + +graph LR + BB[BB & RF] + +``` + +Figure 2-3: Indoor All-In-One Architecture diagram. It shows a single dashed box labeled 'BB & RF'. + +**Figure 2-3: Indoor All-In-One Architecture** + +### 2.2.1 Split RAN Architecture + +For medium and large coverage indoor deployment scenarios, the base station with split RAN architecture is more cost effective. This type of architecture is widely deployed in 4G networks. The main idea of this architecture is “shared cell”. By using the fronthaul gateway, a large number of radio units can then share the same radio spectrum resource in one cell. This configuration is very useful in both low and high capacity scenarios. Therefore, when an O-DU<sub>x</sub> and FHGW<sub>x</sub> are capable of handling cell splits, multiple O-RU<sub>x</sub>(s) can be grouped together to share the radio resources. Accordingly, the choice of fronthaul split option changes the architecture of the base station. WG7 has recognized the following four split option architectures per service providers’ deployment needs which are shown in Figure 2-4 through Figure 2-7. + +#### 1) Option 6 to option 6 split architecture + +In split option 6, the L1 functions are within O-RU<sub>6</sub> while the O-DU<sub>6</sub> contains functions of MAC and above. Figure 2-4 shows the block diagram of base station having an option 6 split architecture. + +![Figure 2-4: Option 6 to Option 6 Split Architecture diagram. It shows an O-CU and O-DU6 (dashed boxes) connected via a dashed line, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. The O-DU6 is connected via an FH Option6 interface to a Switch/Router Or Fronthaul Gateway. This gateway is then connected via an FH Option6 interface to multiple O-RU6 (dashed boxes).](1b678fc5a913eb1046b6c936dfda52a8_img.jpg) + +``` + +graph LR + subgraph Whitebox [O-CU & O-DU may/may not be integrated into one Whitebox] + OCU[O-CU] <--> ODU6[O-DU6] + end + ODU6 <-->|FH Option6| SR[Switch/Router Or Fronthaul Gateway] + SR <-->|FH Option6| ORU1[O-RU6] + SR <-->|FH Option6| ORU2[O-RU6] + SR <-->|FH Option6| ORU3[O-RU6] + +``` + +Figure 2-4: Option 6 to Option 6 Split Architecture diagram. It shows an O-CU and O-DU6 (dashed boxes) connected via a dashed line, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. The O-DU6 is connected via an FH Option6 interface to a Switch/Router Or Fronthaul Gateway. This gateway is then connected via an FH Option6 interface to multiple O-RU6 (dashed boxes). + +**Figure 2-4: Option 6 to Option 6 Split Architecture** + +#### 2) Option 7-2 to option 7-2 split architecture: + +In split option 7-2, low PHY functions reside in the O-RU<sub>7-2</sub>, while the high PHY functions reside in the O-DU<sub>7-2</sub>. O-RAN WG4 CUS-plane spec [4] outlines the details of this split option under different usage scenarios. + +![Figure 2-5: Option 7-2 to Option 7-2 Split Architecture. The diagram shows a dashed box on the left containing O-CU and O-DU, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option7-2' connects O-DU to a central box labeled 'Switch/Router Or Fronthaul Gateway'. From this central box, multiple arrows labeled 'FH Option7-2' point to a vertical stack of O-RU boxes on the right, with vertical ellipsis between the top and bottom O-RU boxes.](a34185e0d7d74f3c8e0ed043775f596d_img.jpg) + +Figure 2-5: Option 7-2 to Option 7-2 Split Architecture. The diagram shows a dashed box on the left containing O-CU and O-DU, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option7-2' connects O-DU to a central box labeled 'Switch/Router Or Fronthaul Gateway'. From this central box, multiple arrows labeled 'FH Option7-2' point to a vertical stack of O-RU boxes on the right, with vertical ellipsis between the top and bottom O-RU boxes. + +**Figure 2-5: Option 7-2 to Option 7-2 Split Architecture** + +#### 3) Option 7-2 to option 8 split: + +This configuration is selected when a deployment scenario requires a radio unit which only supports split option 8 architecture. Since this is currently not part of overall O-RAN architecture, CPRI based option 8 fronthaul and FHGW<sub>7-2→8</sub> will be included in the reference design specification. Figure 2-6 depicts the option 7-2 to option 8 based split architecture. There is no change for the definition of O-DU<sub>7-2</sub>. However, O-RU<sub>8</sub> supports option 8 fronthaul interface while the FHGW<sub>7-2→8</sub> translates the fronthaul protocol between option 7-2 and CPRI. + +![Figure 2-6: Option 7-2 to Option 8 Split Architecture. The diagram shows a dashed box on the left containing O-CU and O-DU7-2, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option7-2' connects O-DU7-2 to a central box labeled 'Fronthaul Gateway with Option Translator'. From this central box, multiple arrows labeled 'FH Option8' point to a vertical stack of O-RU8 boxes on the right, with vertical ellipsis between the top and bottom O-RU8 boxes.](c6addcfe1c47c242a7f08b0bda7673f0_img.jpg) + +Figure 2-6: Option 7-2 to Option 8 Split Architecture. The diagram shows a dashed box on the left containing O-CU and O-DU7-2, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option7-2' connects O-DU7-2 to a central box labeled 'Fronthaul Gateway with Option Translator'. From this central box, multiple arrows labeled 'FH Option8' point to a vertical stack of O-RU8 boxes on the right, with vertical ellipsis between the top and bottom O-RU8 boxes. + +**Figure 2-6: Option 7-2 to Option 8 Split Architecture** + +#### 4) Option 8 to option 8 split architecture: + +Currently, Option 8 is a non-O-RAN defined split option where the CPRI fronthaul interface is needed in order to make the interoperability work with O-DU<sub>8</sub> and O-RU<sub>8</sub> from different vendors. The option 8 fronthaul interface definition and the requirements shall be part of the white box reference design, if adopted. In this case, the O-DU<sub>8</sub> consists of L1 and L2 processing functions. Figure 2-7 shows an option 8 based split architecture. Note that O-CU and O-DU<sub>8</sub> hardware may be integrated into one Whitebox this is also shown in Figure 2-7. + +![Figure 2-7: Option 8 to Option 8 Split Architecture. The diagram shows a dashed box on the left containing O-CU and O-DU8, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option8' connects this box to a 'Fronthaul Gateway' box. From the gateway, multiple arrows labeled 'FH Option8' connect to a vertical stack of O-RU8 boxes on the right.](7e7d27b9422a016de486d2896481c558_img.jpg) + +Figure 2-7: Option 8 to Option 8 Split Architecture. The diagram shows a dashed box on the left containing O-CU and O-DU8, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option8' connects this box to a 'Fronthaul Gateway' box. From the gateway, multiple arrows labeled 'FH Option8' connect to a vertical stack of O-RU8 boxes on the right. + +Figure 2-7: Option 8 to Option 8 Split Architecture + +### 2.2.2 Integrated gNB-DU Architecture + +For integrated gNB-DU, the complete L1/L2 and radio functions are integrated into a single box which includes all logical functions of O-DU and O-RU. 错误!未找到引用源。 shows the block diagram of integrated gNB-DU. The gNB-DU connects with the O-CU through an F1 interface as defined by 3GPP. + +![Figure 2-8: Integrated gNB-DU Architecture. The diagram shows a dashed box on the left labeled 'O-CU'. A solid arrow labeled 'F1' connects it to a larger dashed box on the right labeled 'gNB-DU'. Inside the gNB-DU box, there are two solid boxes: 'O-DU' and 'O-RU', connected by a double-headed arrow.](8234c65fdf5a09f7652f65d9f4982ad8_img.jpg) + +Figure 2-8: Integrated gNB-DU Architecture. The diagram shows a dashed box on the left labeled 'O-CU'. A solid arrow labeled 'F1' connects it to a larger dashed box on the right labeled 'gNB-DU'. Inside the gNB-DU box, there are two solid boxes: 'O-DU' and 'O-RU', connected by a double-headed arrow. + +Figure 2-8: Integrated gNB-DU Architecture + +### 2.2.3 All-In-One Base Station Architecture + +For all-in-one base station, the functions of O-CU, O-DU<sub>x</sub> and O-RU<sub>x</sub> are included in one box which is composed of baseband unit and RF processing unit, as such no FH interface and F1 interface are required to connect them. + +![Figure 2-9: All-In-One Base Station Architecture. The diagram shows a single large dashed box containing the text 'BB & RF'.](f0e001951d41bd82bedcaff7832f8c37_img.jpg) + +Figure 2-9: All-In-One Base Station Architecture. The diagram shows a single large dashed box containing the text 'BB & RF'. + +Figure 2-9: All-In-One Base Station Architecture + +# Chapter 3 White Box Hardware Architecture + +Based on the gNB physical implementation architectures discussed earlier, this chapter provides the architecture, major building blocks and all external/internal interfaces for each Whitebox. + +## 3.1 O-CU Hardware Architecture + +In 3GPP system architecture, the gNB Central Unit (CU) communicates to the Distribution Unit (DU) via an F1 interface. This interface has been adopted by O-RAN Alliance as well. F1 is an IP based protocol interface, which offers more flexibility on O-CU platform design. + +### 3.1.1 O-CU Architecture Diagram + +The O-CU can be implemented with any General-Purpose Processor (GPP) based platform having an optional accelerator block. The O-CU functions can be implemented in either a separated hardware platform or share the same hardware platform with O-DU<sub>x</sub> functions (Integrated). In both cases, the O-CU should be able to leverage the O-DU<sub>x</sub> reference design with relaxed requirements on I/O and network bandwidth capacity. Figure 3-1 shows the hardware blocks and interfaces within the O-CU white box. Refers to the O-DU<sub>x</sub> section for the details of O-CU components and interfaces. + +![Figure 3-1: O-CU White Box Hardware Block Diagram. The diagram shows the internal components of an O-CU white box. A dashed box labeled 'O-CU' contains three main blocks: 'Ethernet Interface', 'Digital Processing Unit', and 'Accelerator'. The 'Ethernet Interface' block is connected to 'Back Haul' (outside the box) and the 'Digital Processing Unit' (inside the box). The 'Digital Processing Unit' is connected to the 'Accelerator' block (inside the box). Below the 'Digital Processing Unit' is another 'Ethernet Interface' block, which is connected to the 'Digital Processing Unit' and the 'F1 Interface' (outside the box). All connections are bidirectional.](7d2aa3aed8874d2b88ee504e9bb097fe_img.jpg) + +``` + +graph LR + subgraph OCU [O-CU] + EI1[Ethernet Interface] <--> DPU[Digital Processing Unit] + DPU <--> Acc[Accelerator] + EI2[Ethernet Interface] <--> DPU + end + BH[Back Haul] <--> EI1 + EI2 <--> F1[F1 Interface] + +``` + +Figure 3-1: O-CU White Box Hardware Block Diagram. The diagram shows the internal components of an O-CU white box. A dashed box labeled 'O-CU' contains three main blocks: 'Ethernet Interface', 'Digital Processing Unit', and 'Accelerator'. The 'Ethernet Interface' block is connected to 'Back Haul' (outside the box) and the 'Digital Processing Unit' (inside the box). The 'Digital Processing Unit' is connected to the 'Accelerator' block (inside the box). Below the 'Digital Processing Unit' is another 'Ethernet Interface' block, which is connected to the 'Digital Processing Unit' and the 'F1 Interface' (outside the box). All connections are bidirectional. + +**Figure 3-1: O-CU White Box Hardware Block Diagram** + +### 3.1.2 O-CU Functional Module Description + +The O-CU functional module description is the same as for the O-DU<sub>7-2</sub> and it is described in Section 3.2.2. + +### 3.1.3 O-CU Interfaces + +The O-CU interfaces are the same as for the O-DU<sub>7-2</sub> and it is described in Section 3.2.3. + +## 3.2 O-DU<sub>7-2</sub> Hardware Architecture + +For split RAN architecture, the functional blocks of RAN physical layer are divided into two parts – high PHY and low PHY. The O-RAN lower layer split is defined in O-RAN WG4 fronthaul interface specification [4]. It also provides the details of the interface protocol as well as function partitions. + +### 3.2.1 O-DU<sub>7-2</sub> Architecture Diagram + +Depending on the 3GPP standards and category of the radio unit, the split function blocks within O-DU<sub>7-2</sub> and O-RU<sub>7-2</sub> may vary accordingly. The O-RAN fronthaul C/U/S-plane specification [4] offers comprehensive information on this topic. The hardware functional partition architecture is shown in Figure 3-2. + +![Figure 3-2: O-DU7-2 with Split Physical Function architecture diagram. The diagram shows two main blocks: O-DU7-2 and O-RU7-2. O-DU7-2 contains an Accelerator, High Phy, Digital Processing Unit, and Ethernet Interface (IEEE1588). O-RU7-2 contains a Low Phy. The Digital Processing Unit in O-DU7-2 is connected to the Accelerator and High Phy. It also has a bidirectional connection to an Ethernet Interface (IEEE1588) within O-DU7-2. This interface is connected to another Ethernet Interface (IEEE1588) located between the two blocks. Finally, this interface connects to the Low Phy in O-RU7-2 via the O-RAN FH Interface.](1f8a8104e29e70c9db067814f7612d08_img.jpg) + +``` + +graph LR + subgraph O-DU7-2 + Accelerator + HighPhy[High Phy] + DPUD[Digital Processing Unit] + E1[Ethernet Interface IEEE1588] + Accelerator --> DPUD + HighPhy --> DPUD + E1 <--> DPUD + end + E1 --> E2[Ethernet Interface IEEE1588] + subgraph O-RU7-2 + LowPhy[Low Phy] + end + E2 <-->|O-RAN FH Interface| LowPhy + +``` + +Figure 3-2: O-DU7-2 with Split Physical Function architecture diagram. The diagram shows two main blocks: O-DU7-2 and O-RU7-2. O-DU7-2 contains an Accelerator, High Phy, Digital Processing Unit, and Ethernet Interface (IEEE1588). O-RU7-2 contains a Low Phy. The Digital Processing Unit in O-DU7-2 is connected to the Accelerator and High Phy. It also has a bidirectional connection to an Ethernet Interface (IEEE1588) within O-DU7-2. This interface is connected to another Ethernet Interface (IEEE1588) located between the two blocks. Finally, this interface connects to the Low Phy in O-RU7-2 via the O-RAN FH Interface. + +Figure 3-2: O-DU<sub>7-2</sub> with Split Physical Function + +### 3.2.2 O-DU<sub>7-2</sub> Functional Module Description + +O-DU<sub>7-2</sub> or O-CU hardware components selection is a product design specific task. Figure 3-3 shows the required components of O-DU<sub>7-2</sub>. Their descriptions and requirements are as follows: + +#### Digital Processing Unit + +The processing unit can be any GPP or digital signal processor (DSP), with I/O chipset. It may also be in the form of System-On-Chip (SOC), or Multi-Chip Package (MCP). + +#### Memory + +DDR memory devices are used to store the runtime data and software for the processing unit. + +#### Flash Memory + +On board non-volatile storage device is used to store the firmware and non-volatile data, such as log data. + +#### Board Management Controller + +The controller is used to manage/control the power and monitors the operational status of the board. + +#### Storage Device + +The storage device such as hard drive is used to store OS, driver and applications software. + +#### Ethernet Controller + +The Ethernet ports transport the fronthaul or backhaul traffic according to the gNB hardware node requirements. The Ethernet device shall support IEEE1588 based timing synchronization. + +#### Accelerator + +The accelerator is an optional device. For performance improvement, hardware accelerator can be used for any process function (e.g. Forward Error Correction (FEC)). + +![Figure 3-3: O-DU7.2 Functional Block and Interface Diagram. The diagram shows a central 'Digital Processing Unit' block. On the left, it connects to an 'Accelerator' via 'PCIe', 'USB Ports' via 'USB', 'Video Port' via 'VGA', 'PCIe Slots' via 'PCIe', 'Serial Ports' via 'RS232', and 'Timing' via 'Timing Signal'. On the right, it connects to 'DDR RAM' via 'Memory Channel', 'Flash Memory' via 'SPI', 'SMBus Port' via 'SMBus', 'Storage Drives' via 'SATA', and 'Ethernet Ports' via 'Ethernet'.](524324c873b0cb44a0a30e6b0a4374af_img.jpg) + +Figure 3-3: O-DU7.2 Functional Block and Interface Diagram. The diagram shows a central 'Digital Processing Unit' block. On the left, it connects to an 'Accelerator' via 'PCIe', 'USB Ports' via 'USB', 'Video Port' via 'VGA', 'PCIe Slots' via 'PCIe', 'Serial Ports' via 'RS232', and 'Timing' via 'Timing Signal'. On the right, it connects to 'DDR RAM' via 'Memory Channel', 'Flash Memory' via 'SPI', 'SMBus Port' via 'SMBus', 'Storage Drives' via 'SATA', and 'Ethernet Ports' via 'Ethernet'. + +**Figure 3-3: O-DU<sub>7.2</sub> Functional Block and Interface Diagram.** + +### 3.2.3 O-DU<sub>7.2</sub> Interfaces + +The O-DU<sub>7.2</sub> supported interfaces described below are also shown in Figure 3-3. + +#### Memory Channel Interface + +Support DDR4 and later memory interface. + +#### PCIe Interface + +Support for PCIe v3 and later interface; the bandwidth depends on the use cases, and it can be used to connect an accelerator device or network card. + +#### Ethernet Interfaces + +Supports any one or combination of GbE/10GbE/25GbE/40GbE links. + +#### Serial ATA Interface + +SATA3 shall be supported in case of software storage, such as hard drive. + +#### SPI Interface + +The SPI interface connects the processor with flash type of device for firmware. + +#### Video Interface + +Video interface is optional. + +#### USB Interface + +Used to connect with local device for debug or on-board firmware update. + +#### Miscellaneous Interface + +Other interfaces that may be needed such as serial port, JTAG, etc. + +## 3.3 O-DU<sub>6</sub> Hardware Architecture + +Hardware architecture for base stations deploying architecture with split option 6 are described in the following sections. + +### 3.3.1 O-DU<sub>6</sub> Architecture Diagram + +O-DU<sub>6</sub> and O-RU<sub>6</sub> are connected via Ethernet based nFAPI interface[6]. O-RU<sub>6</sub> includes complete physical layer processing functions, thus the O-DU<sub>6</sub> handles L2 and L3 processing functions. The O-DU<sub>6</sub> hardware architecture is shown in Figure 3-4. + +![Figure 3-4: O-DU6 Architecture Diagram. The diagram shows the internal architecture of the O-DU6 and its connection to the O-RU6. The O-DU6 is enclosed in a dashed box and contains three main components: an 'Ethernet Interface (IEEE1588)' on the left, a 'Digital Processing Unit' in the center, and another 'Ethernet Interface (IEEE1588)' on the right. Bidirectional arrows connect the left Ethernet interface to the Digital Processing Unit, and the Digital Processing Unit to the right Ethernet interface. A curved arrow also points from the right Ethernet interface back to the Digital Processing Unit. The O-RU6 is shown to the right of the O-DU6, containing an 'Ethernet Interface (IEEE1588)' and a 'Hi+Low Phy' block. A bidirectional arrow labeled 'nFAPI FH Interface' connects the right Ethernet interface of the O-DU6 to the Ethernet interface of the O-RU6.](cfe2ecc03d5304a23e5c17fc8fbe1b25_img.jpg) + +Figure 3-4: O-DU6 Architecture Diagram. The diagram shows the internal architecture of the O-DU6 and its connection to the O-RU6. The O-DU6 is enclosed in a dashed box and contains three main components: an 'Ethernet Interface (IEEE1588)' on the left, a 'Digital Processing Unit' in the center, and another 'Ethernet Interface (IEEE1588)' on the right. Bidirectional arrows connect the left Ethernet interface to the Digital Processing Unit, and the Digital Processing Unit to the right Ethernet interface. A curved arrow also points from the right Ethernet interface back to the Digital Processing Unit. The O-RU6 is shown to the right of the O-DU6, containing an 'Ethernet Interface (IEEE1588)' and a 'Hi+Low Phy' block. A bidirectional arrow labeled 'nFAPI FH Interface' connects the right Ethernet interface of the O-DU6 to the Ethernet interface of the O-RU6. + +**Figure 3-4: O-DU<sub>6</sub> Architecture Diagram** + +### 3.3.2 O-DU<sub>6</sub> Functional Module Description + +O-DU<sub>6</sub> hardware functional blocks are the same as the modules used by O-DU<sub>7-2</sub>. A detailed description of O-DU<sub>7-2</sub> modules is given in Section 3.2.2. However, note that O-DU<sub>6</sub> does not require an accelerator module since all physical layer functions are handled by O-RU<sub>6</sub>. + +### 3.3.3 O-DU<sub>6</sub> Interfaces + +The O-DU<sub>6</sub> interfaces are the same as O-DU<sub>7-2</sub> interfaces which are described in section 3.2.3. + +## 3.4 O-DU<sub>8</sub> Hardware Architecture + +Base stations deploying split architecture option 8 have their baseband processing and radio processing units physically separated from one another. For this type of functional partition, CPRI must be used as fronthaul interface between O-DU<sub>8</sub> and O-RU<sub>8</sub>. The architecture for O-DU<sub>8</sub> is described in the following sections + +### 3.4.1 O-DU<sub>8</sub> Architecture Diagram + +O-DU<sub>8</sub> shall contain complete physical layer processing operation. The details of CPRI interface will be provided as part of the reference design if this option is selected by the system designer. The hardware functional partition architecture is shown in Figure 3-5. + +![Figure 3-5: O-DU8 Architecture Diagram. The diagram shows the internal architecture of O-DU8 and its connection to O-RU8. O-DU8 is enclosed in a dashed box and contains an Accelerator, Hi + Low Phy, Digital Processing Unit, and Ethernet Interface (IEEE1588). The Accelerator and Hi + Low Phy both connect to the Digital Processing Unit. The Ethernet Interface connects to the Digital Processing Unit via a bidirectional arrow. The Digital Processing Unit connects to a CPRI block via a bidirectional arrow. This CPRI block connects to another CPRI block in O-RU8 via a bidirectional arrow labeled 'CPRI Interface'.](e30f911a9db20da291ea8653e125c407_img.jpg) + +Figure 3-5: O-DU8 Architecture Diagram. The diagram shows the internal architecture of O-DU8 and its connection to O-RU8. O-DU8 is enclosed in a dashed box and contains an Accelerator, Hi + Low Phy, Digital Processing Unit, and Ethernet Interface (IEEE1588). The Accelerator and Hi + Low Phy both connect to the Digital Processing Unit. The Ethernet Interface connects to the Digital Processing Unit via a bidirectional arrow. The Digital Processing Unit connects to a CPRI block via a bidirectional arrow. This CPRI block connects to another CPRI block in O-RU8 via a bidirectional arrow labeled 'CPRI Interface'. + +**Figure 3-5: O-DU<sub>8</sub> Architecture Diagram** + +### 3.4.2 O-DU<sub>8</sub> Functional Module Description + +Most of hardware modules in O-DU<sub>8</sub> are the same as the modules used by O-DU<sub>7.2</sub>. Section 3.2.2 has the detailed description of those components. The differences between O-DU<sub>8</sub> and O-DU<sub>7.2</sub> are the fronthaul interface and the physical layer functions that are performed within O-DU<sub>8</sub> (i.e., O-DU<sub>8</sub> performs all PHY functions vs O-DU<sub>7.2</sub> only performs High PHY functions). In O-DU<sub>8</sub>, CPRI interface is used for fronthaul. Figure 3-6 shows the various components used in O-DU<sub>8</sub>, and additional functional modules are elaborated in the following: + +#### CPRI Interface Device + +This device provides the CPRI protocol used for the fronthaul interface. + +![Figure 3-6: O-DU8 Functional Block and Interface Diagram. The diagram shows the Digital Processing Unit at the center, connected to various functional blocks. On the left, an Accelerator connects via PCIe, USB Ports via USB, Video Port via VGA, PCIe Slots via PCIe, Serial Ports via RS232, and Timing via Timing Signal. On the right, a CPRI Interface Device connects via PCIe, DDR RAM via Memory Channel, Flash Memory via SPI, SMBus Port via SMBus, Storage Drives via SATA, and Ethernet Ports via Ethernet.](d4e2e9b7ddec74c65a936c494bd18f8e_img.jpg) + +Figure 3-6: O-DU8 Functional Block and Interface Diagram. The diagram shows the Digital Processing Unit at the center, connected to various functional blocks. On the left, an Accelerator connects via PCIe, USB Ports via USB, Video Port via VGA, PCIe Slots via PCIe, Serial Ports via RS232, and Timing via Timing Signal. On the right, a CPRI Interface Device connects via PCIe, DDR RAM via Memory Channel, Flash Memory via SPI, SMBus Port via SMBus, Storage Drives via SATA, and Ethernet Ports via Ethernet. + +**Figure 3-6: O-DU<sub>8</sub> Functional Block and Interface Diagram** + +### 3.4.3 O-DU<sub>8</sub> Interfaces + +Among the O-DU<sub>8</sub> interfaces, CPRI is the fronthaul interface that is different from the O-DU<sub>7-2</sub> and is described below. The rest of the interfaces are the same as O-DU<sub>7-2</sub> interfaces which are described in section 3.2.3. + +#### CPRI Interface + +The CPRI interface shall comply with CPRI specification [5]. + +## 3.5 FHGW<sub>7-2</sub> - Option 7-2 to Option 7-2 Hardware Architecture + +For the indoor picocell system, FHGW<sub>7-2</sub> performs the aggregation/distribution function for the uplink/downlink traffic to all the radio units. FHGW<sub>7-2</sub> has an upper interface which connects with O-DU<sub>7-2</sub>, and a lower interface connected with O-RU<sub>7-2</sub>. Here, both interfaces are based on the O-RAN WG4 defined fronthaul interface. FHGW<sub>7-2</sub> supports NR by default but LTE is not precluded. + +### 3.5.1 FHGW<sub>7-2</sub> Architecture Diagram + +Figure 3-7 depicts a FHGW<sub>7-2</sub> architecture diagram. The signal processing unit is the key component of the FHGW<sub>7-2</sub> which handles all the uplink and downlink traffic combining and distribution. The signal processing block can be either an FPGA or another digital processing unit. The back end and front end fronthaul interfaces are both Ethernet. In the front end direction, there is a broadcast function for connecting O-RU<sub>7-2</sub>(s) and cascaded FHGW<sub>7-2</sub> with the same cell ID, and a demultiplex function for connecting O-RU<sub>7-2</sub>(s) and FHGW<sub>7-2</sub> with different cell IDs. In the back end direction, all signals from connected O-RU<sub>7-2</sub>(s) and FHGW<sub>7-2</sub> with same cell ID could be combined. See Figure below. + +![FHGW7-2 Architecture Diagram](bfda6380216d4064380ea0eab297d80f_img.jpg) + +``` + +graph LR + subgraph FHGW7-2 + O-RAN_FH_Back_End_Interface[O-RAN FH Back End Interface] <--> Digital_Processing_Unit[Digital Processing Unit] + Digital_Processing_Unit <--> O-RAN_FH_Front_End_Interfaces[O-RAN FH Front End Interfaces] + end + To_From_ODU7-2[To/From O-DU7-2] <--> O-RAN_FH_Back_End_Interface + O-RAN_FH_Front_End_Interfaces <--> To_From_ORU7-2[To/From O-RU7-2] + +``` + +The diagram illustrates the architecture of the FHGW<sub>7-2</sub> unit. It is enclosed in a dashed box labeled 'FHGW<sub>7-2</sub>'. Inside, there are three main components connected by bidirectional arrows: 'O-RAN FH Back End Interface', 'Digital Processing Unit', and 'O-RAN FH Front End Interfaces'. The 'O-RAN FH Back End Interface' is connected to 'To/From O-DU<sub>7-2</sub>' on the left. The 'O-RAN FH Front End Interfaces' is connected to 'To/From O-RU<sub>7-2</sub>' on the right. + +FHGW7-2 Architecture Diagram + +Figure 3-7: FHGW<sub>7-2</sub> Architecture Diagram + +### 3.5.2 FHGW<sub>7-2</sub> Functional Module Description + +The FHGW<sub>7-2</sub> functional module diagram is shown in Figure 3-8. The components include: + +- Digital processing Unit: handles all the computation and signal processing functions. +- POE++: provides power over Ethernet. +- DC/DC: performs DC to DC conversion. +- CLK: provides the clock signals to the FHGW<sub>7-2</sub> + +- Memory: on board memory for data storage +- SPI: interface to connect with flash device for software and configuration data +- Debug Interface: interface is used for debugging purposes +- Ethernet: interfaces to connect with O-RU<sub>7-2</sub> And O-DU<sub>7-2</sub> + +![Figure 3-8: FHGW7-2 Functional Module Diagram. A central 'Digital Processing Unit' block is connected to 'POE++', 'DC/DC', and 'CLK' on the left, and 'Memory', 'SPI', 'Debug Interface', and 'Ethernets' on the right. All connections are bidirectional.](22c2ae84062e3660ea32773be45bb23d_img.jpg) + +``` + +graph LR + subgraph FHGW7-2 [FHGW7-2 Functional Module] + DP[Digital Processing Unit] + POE[POE++] + DC[DC/DC] + CLK[CLK] + Mem[Memory] + SPI[SPI] + Debug[Debug Interface] + Ethernets[Ethernets] + DP <--> POE + DP <--> DC + DP <--> CLK + DP <--> Mem + DP <--> SPI + DP <--> Debug + DP <--> Ethernets + end + +``` + +Figure 3-8: FHGW7-2 Functional Module Diagram. A central 'Digital Processing Unit' block is connected to 'POE++', 'DC/DC', and 'CLK' on the left, and 'Memory', 'SPI', 'Debug Interface', and 'Ethernets' on the right. All connections are bidirectional. + +**Figure 3-8: FHGW<sub>7-2</sub> Functional Module Diagram** + +## 3.6 FHGW<sub>6</sub> - Option 6 to Option 6 Hardware Architecture + +No FHGW is needed for this indoor deployment scenario when adopting split option 6. + +## 3.7 FHGW<sub>7-2->8</sub> - Option 7-2 to Option 8 Hardware Architecture + +FHGW<sub>7-2->8</sub> performs both radio traffic multiplexing and fronthaul protocol translation tasks. + +### 3.7.1 FHGW<sub>7-2->8</sub> Architecture Diagram + +Figure 3-9 illustrates the FHGW<sub>7-2->8</sub> architecture. For FHGW<sub>7-2->8</sub>, the digital processing unit can be the same as described in Section 3.5.1. With FHGW<sub>7-2->8</sub>, the back end interface is Ethernet, while the front end interfaces are CPRI. The digital processing unit block shall conduct the protocol translation between the front end and back end interfaces. + +![Figure 3-9: FHGW7-2->8 Architecture Diagram. A dashed box labeled 'FHGW7-2->8' contains three main blocks: 'O-RAN FH Back End Interface', 'Digital Processing Unit', and 'Option 8 Front End Interfaces'. Bidirectional arrows connect 'To/From O-DU7-2' to the back end interface, the back end interface to the digital processing unit, the digital processing unit to the front end interfaces, and the front end interfaces to 'To/From O-RU8'.](80c33f22bb32aee93289e3e5a1a04d1d_img.jpg) + +``` + +graph LR + subgraph FHGW7-2->8 [FHGW7-2->8] + BEI[O-RAN FH Back End Interface] + DPU[Digital Processing Unit] + FEI[Option 8 Front End Interfaces] + BEI <--> DPU + DPU <--> FEI + end + ODU[To/From O-DU7-2] <--> BEI + FEI <--> ORU[To/From O-RU8] + +``` + +Figure 3-9: FHGW7-2->8 Architecture Diagram. A dashed box labeled 'FHGW7-2->8' contains three main blocks: 'O-RAN FH Back End Interface', 'Digital Processing Unit', and 'Option 8 Front End Interfaces'. Bidirectional arrows connect 'To/From O-DU7-2' to the back end interface, the back end interface to the digital processing unit, the digital processing unit to the front end interfaces, and the front end interfaces to 'To/From O-RU8'. + +**Figure 3-9: FHGW<sub>7-2->8</sub> Architecture Diagram** + +### 3.7.2 FHGW<sub>7-2→8</sub> Functional Module Description + +Figure 3-10 is the FHGW<sub>7-2→8</sub> functional module diagram. There is one 25G SFP+ port for back end link, one 25G SFP+ port for cascade link, and eight 10G CPRI ports for front end links. The front end ports also support remote power supply for O-RU<sub>8</sub>(s) via POE++. In the forward direction, FHGW<sub>7-2→8</sub> may connect an O-DU<sub>7-2</sub> to other O-RU<sub>8</sub>(s) via a cascaded FHGW<sub>8</sub> supporting both the same and different cell IDs. However, it can also support demultiplexing functions for connecting O-RU<sub>8</sub>(s) with different cell IDs. In the back end direction, all signals from connected O-RU<sub>8</sub>(s) with the same cell IDs are combined via FHGW<sub>7-2→8</sub> towards O-DU<sub>7-2</sub>. + +As different fronthaul interfaces are used by FHGW<sub>7-2→8</sub>, it will translate the fronthaul protocol between front end and back end. FHGW<sub>7-2→8</sub> shall also provide the low physical layer function. + +![Figure 3-10: FHGW7-2→8 Functional Module Diagram. The diagram shows a central 'Digital Processing Unit' box. To its left, four boxes are connected: 'POE++', 'DC/DC', 'CLK', and 'Ethernet'. To its right, four boxes are connected: 'Memory', 'SPI', 'Debug Interface', and 'CPRI'. All connections are bidirectional.](dd590e7a556655956f9a46f8a7105d44_img.jpg) + +``` + +graph LR + subgraph FHGW7-2_8 [FHGW7-2→8 Functional Module] + DP[Digital Processing Unit] + POE[POE++] + DC[DC/DC] + CLK[CLK] + Ethernet[Ethernet] + Memory[Memory] + SPI[SPI] + Debug[Debug Interface] + CPRI[CPRI] + DP <--> POE + DP <--> DC + DP <--> CLK + DP <--> Ethernet + DP <--> Memory + DP <--> SPI + DP <--> Debug + DP <--> CPRI + end + +``` + +Figure 3-10: FHGW7-2→8 Functional Module Diagram. The diagram shows a central 'Digital Processing Unit' box. To its left, four boxes are connected: 'POE++', 'DC/DC', 'CLK', and 'Ethernet'. To its right, four boxes are connected: 'Memory', 'SPI', 'Debug Interface', and 'CPRI'. All connections are bidirectional. + +**Figure 3-10: FHGW<sub>7-2→8</sub> Functional Module Diagram** + +The FHGW<sub>7-2→8</sub> functional module diagram is shown in Figure 3-10. The components include: + +- Digital processing Unit: handles all the computation and signal processing functions. +- POE++: provides power over Ethernet. +- DC/DC: performs DC to DC conversion. +- CLK: provides the clock signals to the FHGW<sub>7-2</sub> +- Memory: on board memory for data storage. +- SPI: interface to connect with flash device for software and configuration data. +- Debug Interface: The interface is used for debugging purposes. +- Ethernet: provides connection from O-DU<sub>7-2</sub> to FHGW<sub>7-2→8</sub> +- CPRI: provides fronthaul connection from FHGW<sub>7-2→8</sub> to O-RU<sub>8</sub> + +## 3.8 FHGW<sub>8</sub> - Option 8 to Option 8 Hardware Architecture + +For option 8 to option 8 fronthaul gateway, both the front end and back end interfaces of FHGW<sub>8</sub> are based on CPRI. + +### 3.8.1 FHGW<sub>8</sub> Architecture Diagram + +Figure 3-11 illustrates the HW architecture FHGW<sub>8</sub>. Note that the front end and the back end interfaces are both CPRI. The digital processing unit handles I/Q samples and all interface processing. FHGW<sub>8</sub> shall also + +provide remote power supply functionality to the O-RU<sub>8</sub> and may be optionally cascaded with other(s) FHGW<sub>8</sub>. + +![Figure 3-11: FHGW8 Architecture Diagram. The diagram shows a dashed box labeled 'FHGW8' containing three main components: 'Option8 Back End Interface', 'Digital Processing Unit', and 'Option 8 Front End Interfaces'. Bidirectional arrows connect 'To/From O-DU8' to the 'Option8 Back End Interface', the 'Option8 Back End Interface' to the 'Digital Processing Unit', the 'Digital Processing Unit' to the 'Option 8 Front End Interfaces', and the 'Option 8 Front End Interfaces' to 'To O-RU8'.](b2ff5da9c9469be2ae8486181e3ab211_img.jpg) + +Figure 3-11: FHGW8 Architecture Diagram. The diagram shows a dashed box labeled 'FHGW8' containing three main components: 'Option8 Back End Interface', 'Digital Processing Unit', and 'Option 8 Front End Interfaces'. Bidirectional arrows connect 'To/From O-DU8' to the 'Option8 Back End Interface', the 'Option8 Back End Interface' to the 'Digital Processing Unit', the 'Digital Processing Unit' to the 'Option 8 Front End Interfaces', and the 'Option 8 Front End Interfaces' to 'To O-RU8'. + +**Figure 3-11: FHGW<sub>8</sub> Architecture Diagram** + +### 3.8.2 FHGW<sub>8</sub> Functional Module Description + +Figure 3-12 illustrates FHGW<sub>8</sub> functional module diagram for an Option 8 CPRI switch. As shown in the FHGW<sub>8</sub> diagram, there is one 25G SFP+ port for back end link to O-DU<sub>8</sub>, one 25G SFP+ port for cascade link, and eight 10G ports for front end links. All these ports support CPRI, while the front end ports further support remote power supply for O-RU<sub>8</sub> connection. In the front end direction, there is a broadcast function for connecting O-RU<sub>8</sub>(s) and cascaded FHGW<sub>8</sub> with the same cell ID, and a demultiplex function for connecting O-RU<sub>8</sub>(s) and FHGW<sub>8</sub> with different cell IDs. In the back end direction, all signals from connected O-RU<sub>8</sub>(s) with the same cell ID could be combined to O-DU<sub>8</sub>. + +![Figure 3-12: FHGW8 Functional Module Diagram. The diagram shows a central 'Digital Processing Unit' box. On the left, three boxes labeled 'POE++', 'DC/DC', and 'CLK' have arrows pointing to the 'Digital Processing Unit'. On the right, four boxes labeled 'Memory', 'SPI', 'Debug Interface', and 'CPRI' have arrows pointing from the 'Digital Processing Unit'.](f07c05f2fc9c1fc009aa4f945c6bc737_img.jpg) + +Figure 3-12: FHGW8 Functional Module Diagram. The diagram shows a central 'Digital Processing Unit' box. On the left, three boxes labeled 'POE++', 'DC/DC', and 'CLK' have arrows pointing to the 'Digital Processing Unit'. On the right, four boxes labeled 'Memory', 'SPI', 'Debug Interface', and 'CPRI' have arrows pointing from the 'Digital Processing Unit'. + +**Figure 3-12: FHGW<sub>8</sub> Functional Module Diagram** + +The FHGW<sub>8</sub> functional module diagram is shown in Figure 3-12. The components include: + +- Digital processing Unit: handles all the computation and signal processing functions. +- POE++: provides power over Ethernet +- DC/DC: performs DC to DC conversion. +- CLK: provides the clock signals to the FHGW<sub>7-2</sub> +- Memory: on board memory for data storage. +- SPI: interface to connect with flash device for software and configuration data. +- Debug Interface: interface used for debug. + +- CPRI: provides connection from O-DU<sub>8</sub> to FHGW<sub>8</sub> and from FHGW<sub>8</sub> to O-RU<sub>8</sub>. + +## 3.9 O-RU<sub>7-2</sub> Hardware Architecture + +**O-RU<sub>7-2</sub> consists of three major units, namely digital processing unit, RF processing unit and a timing unit as shown in Figure 3-13.** The Ethernet interface complies with O-RAN WG4 open fronthaul interface. O-RU<sub>7-2</sub> can directly connect with O-DU<sub>7-2</sub> or connect through a FHGW<sub>7-2</sub>. While O-RU<sub>7-2</sub> HW supports NR by default, LTE is not precluded. + +### 3.9.1 O-RU<sub>7-2</sub> Architecture Diagram + +O-RU<sub>7-2</sub> HW architecture consists of digital processing unit which handles all digital signal and interface processing and a RF processing unit handling all analog. There will be a transceiver right after digital processing block which converts between digital signals and analog signals, as well as frequency mixing. Then the PA/LNA amplifies the RF signal, and the antenna will be used to transmit and receive signal over the air. There is at least one Ethernet port available which is used as the O-RAN fronthaul interface. + +![Figure 3-13: O-RU7-2 Architecture Diagram. The diagram shows the internal architecture of an O-RU7-2 unit. A dashed box labeled 'O-RU7-2' contains four main blocks: 'Ethernet', 'Digital Processing Unit', 'RF Processing Unit', and 'Timing Unit'. The 'Timing Unit' is at the bottom and has arrows pointing up to the 'Ethernet', 'Digital Processing Unit', and 'RF Processing Unit'. The 'Ethernet' block is on the left, connected to 'To/From O-DU7-2' via a double-headed arrow labeled 'O-RAN FH'. The 'Ethernet' block is also connected to the 'Digital Processing Unit' with a double-headed arrow. The 'Digital Processing Unit' is connected to the 'RF Processing Unit' with a double-headed arrow.](8fc8e2925dd061c737741809b41656b5_img.jpg) + +``` + +graph LR + subgraph O-RU7-2 + Ethernet[Ethernet] <--> DPU[Digital Processing Unit] + DPU <--> RPU[RF Processing Unit] + TU[Timing Unit] --> Ethernet + TU --> DPU + TU --> RPU + end + Ethernet <-->|O-RAN FH| ODU7-2[To/From O-DU7-2] + +``` + +Figure 3-13: O-RU7-2 Architecture Diagram. The diagram shows the internal architecture of an O-RU7-2 unit. A dashed box labeled 'O-RU7-2' contains four main blocks: 'Ethernet', 'Digital Processing Unit', 'RF Processing Unit', and 'Timing Unit'. The 'Timing Unit' is at the bottom and has arrows pointing up to the 'Ethernet', 'Digital Processing Unit', and 'RF Processing Unit'. The 'Ethernet' block is on the left, connected to 'To/From O-DU7-2' via a double-headed arrow labeled 'O-RAN FH'. The 'Ethernet' block is also connected to the 'Digital Processing Unit' with a double-headed arrow. The 'Digital Processing Unit' is connected to the 'RF Processing Unit' with a double-headed arrow. + +**Figure 3-13: O-RU<sub>7-2</sub> Architecture Diagram** + +### 3.9.2 O-RU<sub>7-2</sub> Functional Module Description + +Figure 3-14 illustrates the O-RU<sub>7-2</sub> functional module blocks that support O-RAN fronthaul with split option 7-2. There is at least one interface port which supports all fronthaul interface and PoE functionalities. The digital processing unit block of O-RU<sub>7-2</sub> is mainly responsible for low PHY functions such as FFT/iFFT, CP addition/removal, and PRACH filtering. Digital Down Converter (DDC), Digital Up Converter (DUC), Crest Factor Reduction (CFR) and Digital Pre-Distortion (DPD) are used for digital data processing. For bandwidth reduction, O-RU<sub>7-2</sub> architecture also supports the optional compression and decompression functions of FH interface. RF Processing Unit consists of the following blocks: Transceiver, Power Amplifier (PA)/ Low Noise Amplifier (LNA) and antenna. Transceiver is used for function of Analog to Digital Converter (ADC), Digital to Analog Converter (DAC) and mixer. The Timing unit may include Phase Locked Loop (PLL), local oscillator and other timing synchronization circuitries. + +![Figure 3-14: O-RU7-2 Functional Module Diagram. This block diagram shows the internal architecture of an O-RU7-2. It is connected to a 'To/From FHGW7-2' via an 'Ethernet Interface'. The main body is divided into two primary units: the 'Digital Processing Unit' and the 'RF Processing Unit'. The Digital Processing Unit contains a sequence of blocks: 'O-RAN FH/1588', '(de)compression/ Low L1', 'DDC/ DUC', and 'CFR/ DPD'. The RF Processing Unit contains 'Transceiver ADC/DAC And MIXER', 'PA/ LNA', and 'ANT'. A 'Timing Unit' at the bottom provides synchronization signals to the Ethernet Interface, the Digital Processing Unit, and the RF Processing Unit.](920f3765f97dd46f52d1a4b6e8e085d2_img.jpg) + +Figure 3-14: O-RU7-2 Functional Module Diagram. This block diagram shows the internal architecture of an O-RU7-2. It is connected to a 'To/From FHGW7-2' via an 'Ethernet Interface'. The main body is divided into two primary units: the 'Digital Processing Unit' and the 'RF Processing Unit'. The Digital Processing Unit contains a sequence of blocks: 'O-RAN FH/1588', '(de)compression/ Low L1', 'DDC/ DUC', and 'CFR/ DPD'. The RF Processing Unit contains 'Transceiver ADC/DAC And MIXER', 'PA/ LNA', and 'ANT'. A 'Timing Unit' at the bottom provides synchronization signals to the Ethernet Interface, the Digital Processing Unit, and the RF Processing Unit. + +Figure 3-14: O-RU<sub>7-2</sub> Functional Module Diagram + +## 3.10 O-RU<sub>6</sub> Hardware Architecture + +O-RU<sub>6</sub> may be deployed in an integrated or split architecture, using the MAC/PHY split defined by the Small Cell Forum's FAPI or nFAPI interface [5]. + +### 3.10.1 O-RU<sub>6</sub> Architecture Diagram + +O-RU<sub>6</sub> consists of three major Units, namely digital processing unit, RF processing unit and a timing unit as shown in Figure 3-15. Option 6 is referred to as interface between PHY and MAC as defined by the Small Cell Forum [6] and is carried by the fronthaul interface over Ethernet as shown in Figure 3-15. In the next section there is a brief functional description of modules within these major blocks of O-RU<sub>6</sub>. + +![Figure 3-15: O-RU6 Architecture Diagram. This diagram shows the high-level architecture of O-RU6. It is connected to an external 'O-CU/O-DU6/ FHGW6' via an 'nFAPI' interface. Inside the O-RU6 boundary, there is an 'Ethernet' block that interfaces with the 'Digital Processing Unit' and the 'RF Processing Unit'. A 'Timing Unit' at the bottom provides synchronization to the Ethernet, Digital Processing Unit, and RF Processing Unit.](e5b6fbacd157b8df16039ec62378e49c_img.jpg) + +Figure 3-15: O-RU6 Architecture Diagram. This diagram shows the high-level architecture of O-RU6. It is connected to an external 'O-CU/O-DU6/ FHGW6' via an 'nFAPI' interface. Inside the O-RU6 boundary, there is an 'Ethernet' block that interfaces with the 'Digital Processing Unit' and the 'RF Processing Unit'. A 'Timing Unit' at the bottom provides synchronization to the Ethernet, Digital Processing Unit, and RF Processing Unit. + +Figure 3-15: O-RU<sub>6</sub> Architecture Diagram + +### 3.10.2 O-RU<sub>6</sub> Functional Module Description + +Figure 3-16 shows the major components used in O-RU<sub>6</sub>. + +The digital processing unit handles transport/interface processing, complete PHY (low and high PHY functions) modem processing, Digital Down Converter (DDC), Digital Up Converter (DUC), Crest Factor Reduction (CFR) and Digital Pre-Distortion (DPD). + +The RF processing unit is comprised of the transceiver block which is responsible for functions such as Analog to Digital Converter (ADC), Digital to Analog Converter (DAC) and mixer, an amplification block + +which contains Power Amplifier (PA)/ Low Noise Amplifier (LNA), etc and antenna subsystem that captures and/or transmits radio electromagnetic waves. O-RU<sub>6</sub> may use Power over Ethernet (PoE) to simplify deployment complexity. + +The Timing Unit may include Phase Locked Loop (PLL), local oscillator and timing synchronization circuitry. + +![Figure 3-16: O-RU6 Functional Module Diagram. The diagram shows the internal architecture of an O-RU6. It is divided into two main units: the Digital Processing Unit and the RF Processing Unit. The Digital Processing Unit contains an nFAPI Handler, Hi +Lo PHY, DDC/ DUC, and CFR/ DPD blocks. The RF Processing Unit contains a Transceiver ADC/DAC and MIXER, PA/ LNA, and ANT blocks. An Ethernet Interface block connects the Digital Processing Unit to the 'To/From O-DU6' external interface. A Timing Unit block provides synchronization to the Hi +Lo PHY, the Transceiver, and the PA/ LNA blocks.](17253f7fba745802bbe52a2ca1b37ec4_img.jpg) + +``` + +graph LR + subgraph O-RU6 + subgraph Digital_Processing_Unit [Digital Processing Unit] + nFAPI_Handler[nFAPI Handler] <--> Hi_Lo_PHY[Hi +Lo PHY] + Hi_Lo_PHY <--> DDC_DUC[DDC/ DUC] + DDC_DUC <--> CFR_DPD[CFR/ DPD] + end + subgraph RF_Processing_Unit [RF Processing Unit] + Transceiver[Transceiver ADC/DAC and MIXER] <--> PA_LNA[PA/ LNA] + PA_LNA <--> ANT[ANT] + end + Ethernet_Interface[Ethernet Interface] <--> nFAPI_Handler + Timing_Unit[Timing Unit] --> Hi_Lo_PHY + Timing_Unit --> Transceiver + Timing_Unit --> PA_LNA + end + O_DU6[To/From O-DU6] <--> Ethernet_Interface + +``` + +Figure 3-16: O-RU6 Functional Module Diagram. The diagram shows the internal architecture of an O-RU6. It is divided into two main units: the Digital Processing Unit and the RF Processing Unit. The Digital Processing Unit contains an nFAPI Handler, Hi +Lo PHY, DDC/ DUC, and CFR/ DPD blocks. The RF Processing Unit contains a Transceiver ADC/DAC and MIXER, PA/ LNA, and ANT blocks. An Ethernet Interface block connects the Digital Processing Unit to the 'To/From O-DU6' external interface. A Timing Unit block provides synchronization to the Hi +Lo PHY, the Transceiver, and the PA/ LNA blocks. + +**Figure 3-16: O-RU<sub>6</sub> Functional Module Diagram** + +## 3.11 O-RU<sub>8</sub> Hardware Architecture + +O-RU<sub>8</sub> hardware architecture is similar to O-RU<sub>7-2</sub> as described in the previous section. The major functional differences reside in the fronthaul interface functions and Physical layer functions. Note that in split option 8 architecture, all PHY functions are performed in the O-DU<sub>8</sub>. The digital signal processing block will comprehend the functional differences and make adjustment accordingly. The RF processing blocks are the same in this case. + +### 3.11.1 O-RU<sub>8</sub> Architecture Diagram + +Figure 3-17 shows a complete O-RU<sub>8</sub> architecture diagram. CPRI is adopted as the fronthaul interface in O-RU<sub>8</sub>. The CPRI interface shall be included as part of the white box reference design document. The programmable digital signal processing block handles all I/Q data samples processing, management and control functions. The transceiver block does the radio signal conversion from analog to digital and vice versa. + +![Figure 3-17: O-RU8 Architecture Diagram. This block diagram shows the O-RU8 architecture. An O-DU8/FHGW8 block is connected to a CPRI block via a CPRI interface. The CPRI block is connected to a Digital Processing Unit, which is in turn connected to an RF Processing Unit. A Timing Unit is connected to both the CPRI block and the RF Processing Unit. The entire O-RU8 block is enclosed in a dashed box.](9579a48da2c9c4fff70b893e3730ae35_img.jpg) + +Figure 3-17: O-RU8 Architecture Diagram. This block diagram shows the O-RU8 architecture. An O-DU8/FHGW8 block is connected to a CPRI block via a CPRI interface. The CPRI block is connected to a Digital Processing Unit, which is in turn connected to an RF Processing Unit. A Timing Unit is connected to both the CPRI block and the RF Processing Unit. The entire O-RU8 block is enclosed in a dashed box. + +Figure 3-17: O-RU<sub>8</sub> Architecture Diagram. + +### 3.11.2 O-RU<sub>8</sub> Functional Module Description + +Figure 3-18 depicts functional block diagram of one example of O-RU<sub>8</sub> which supports split architecture with Option 8. The CPRI interface shall be included as part of the Whitebox reference design document. The programmable digital signal processing block handles all I/Q data samples processing, management and control functions. Therefore, within O-RU<sub>8</sub>, there shall be at least copper or fiber interface to support transmission of CPRI protocol. The digital processing unit of O-RU<sub>8</sub> is responsible for CPRI protocol processing, Digital Down Converter (DDC), Digital Up Converter (DUC), Crest Factor Reduction (CFR) and Digital Pre-Distortion (DPD). The RF processing unit is the same as O-RU<sub>7-2</sub>, and O-RU<sub>6</sub>. The Transceiver block comprises of Analog to Digital Converter (ADC), Digital to Analog Converter (DAC) and mixer. The analog blocks include: Power Amplifier (PA)/ Low Noise Amplifier (LNA), etc. The Timing Unit may include Phase Locked Loop (PLL), local oscillator and other timing synchronization circuits. + +![Figure 3-18: O-RU8 Functional Module Diagram. This detailed block diagram shows the functional modules of O-RU8. It includes a CPRI Interface connected to a To/From FHGW8 block. The CPRI Interface is connected to a Digital Processing Unit, which contains a CPRI Proc block, a DDC/DUC block, and a CFR/DPD block. The Digital Processing Unit is connected to an RF Processing Unit, which contains a Transceiver (ADC/DAC and MIXER) block, a PA/LNA block, and an ANT block. A Timing Unit is connected to the CPRI Interface, the Digital Processing Unit, and the RF Processing Unit. The entire O-RU8 block is enclosed in a dashed box.](42b037e260ab397fc6a04774fb441af2_img.jpg) + +Figure 3-18: O-RU8 Functional Module Diagram. This detailed block diagram shows the functional modules of O-RU8. It includes a CPRI Interface connected to a To/From FHGW8 block. The CPRI Interface is connected to a Digital Processing Unit, which contains a CPRI Proc block, a DDC/DUC block, and a CFR/DPD block. The Digital Processing Unit is connected to an RF Processing Unit, which contains a Transceiver (ADC/DAC and MIXER) block, a PA/LNA block, and an ANT block. A Timing Unit is connected to the CPRI Interface, the Digital Processing Unit, and the RF Processing Unit. The entire O-RU8 block is enclosed in a dashed box. + +Figure 3-18: O-RU<sub>8</sub> Functional Module Diagram + +## 3.12 Integrated gNB-DU Hardware Architecture + +Integrated gNB-DU is a platform that where all functionalities of an O-DU and an O-RU are performed in the same Whitebox. The gNB-DU's hardware will support all Layer 1 and Layer 2 functionalities of the base station. + +### 3.12.1 Integrated gNB-DU Architecture Diagram + +Figure 3-19 shows the gNB-DU architecture block diagram. The integrated gNB-DU consists of a digital processing unit, a RF processing unit, and a timing unit. The gNB-DU connects to O-CU through an F1 interface. The contents of the processing units are described next. + +![Figure 3-19: Integrated gNB-DU Architecture Diagram](8b45f6d8d635b4fa0babce326807f284_img.jpg) + +The diagram shows the integrated gNB-DU architecture. A dashed box labeled 'gNB-DU' contains three main blocks: 'Ethernet', 'Digital Processing Unit', and 'RF Processing Unit'. These three blocks are connected to each other with bidirectional arrows. Below these blocks is a 'Timing Unit' block, which has arrows pointing up to each of the three blocks above it. To the left of the 'Ethernet' block, outside the dashed box, is the label 'To/From O-CU' with a bidirectional arrow connecting it to the 'Ethernet' block. The connection between 'To/From O-CU' and 'Ethernet' is labeled 'F1'. + +Figure 3-19: Integrated gNB-DU Architecture Diagram + +**Figure 3-19: Integrated gNB-DU Architecture Diagram** + +### 3.12.2 Integrated gNB-DU Function Module Description + +Figure 3-20 illustrates the gNB-DU function modules diagram. The Ethernet port is used as the interface to the O-CU via an F1 interface. The digital processing unit consists of RLC/MAC processing, physical layer processing, ADC/DAC blocks and CFR/DPD blocks. The RF processing unit includes the transceiver block, ADC/DAC, mixers, PA/LNA/RF filters and Antennas. The timing unit includes PLL, local oscillators, and other timing and synchronization circuitry. Hardware interfaces that are used internally may include PCIe, SPI, JESD, etc. + +![Figure 3-20: Integrated gNB-DU Functional Module Diagram](3ef78a6be10fae1e4802740afcacfc4a_img.jpg) + +The diagram shows the functional modules of the integrated gNB-DU. A dashed box labeled 'gNB-DU' contains an 'Ethernet Interface' block on the left, which connects to 'To/From O-CU' (labeled 'F1'). The 'Ethernet Interface' is connected to a 'Digital Processing Unit' block. Inside the 'Digital Processing Unit' are four sub-blocks: 'RLC/MAC', 'PHY', 'DDC/DUC', and 'CFR/DPD', connected in sequence with bidirectional arrows. The 'Digital Processing Unit' is connected to an 'RF Processing Unit' block. Inside the 'RF Processing Unit' are three sub-blocks: 'Transceiver ADC/DAC and MIXER', 'PA/LNA', and 'ANT', connected in sequence with bidirectional arrows. Below these units is a 'Timing Unit' block, which has arrows pointing up to the 'Ethernet Interface', the 'Digital Processing Unit', and the 'RF Processing Unit'. + +Figure 3-20: Integrated gNB-DU Functional Module Diagram + +**Figure 3-20: Integrated gNB-DU Functional Module Diagram** + +## 3.13 AIO White Box Hardware Architecture + +Based on the gNB physical implementation architectures discussed earlier, this section provides the architecture, major building blocks and all external interfaces for the AIO Whitebox. + +### 3.13.1 AIO Architecture Diagram + +The AIO whitebox hosts L1/L2/L3 functions and radio frequency functions, and all the functions are implemented on the same hardware platforms. Figure 3-21 shows the hardware blocks and external interfaces of AIO Whitebox. + +![Figure 3-21: AIO White box Architecture Diagram. The diagram shows a dashed box labeled 'gNB-AIO' containing four main blocks: 'Ethernet', 'Digital Processing Unit', 'RF Processing Unit', and 'Timing Unit'. The 'Ethernet' block is connected to 'To/From 5GC' via an 'NG' interface. The 'Ethernet' block is connected to the 'Digital Processing Unit' with a bidirectional arrow. The 'Digital Processing Unit' is connected to the 'RF Processing Unit' with a bidirectional arrow. The 'Timing Unit' is connected to both the 'Digital Processing Unit' and the 'RF Processing Unit' with arrows pointing towards them.](0ccb07777b4c50fe9d082db0be1ace22_img.jpg) + +``` + +graph LR + subgraph gNB_AIO [gNB-AIO] + Ethernet[Ethernet] <--> DPU[Digital Processing Unit] + DPU <--> RPU[RF Processing Unit] + TU[Timing Unit] --> DPU + TU --> RPU + end + Ethernet -- NG --> ToFrom5GC[To/From 5GC] + +``` + +Figure 3-21: AIO White box Architecture Diagram. The diagram shows a dashed box labeled 'gNB-AIO' containing four main blocks: 'Ethernet', 'Digital Processing Unit', 'RF Processing Unit', and 'Timing Unit'. The 'Ethernet' block is connected to 'To/From 5GC' via an 'NG' interface. The 'Ethernet' block is connected to the 'Digital Processing Unit' with a bidirectional arrow. The 'Digital Processing Unit' is connected to the 'RF Processing Unit' with a bidirectional arrow. The 'Timing Unit' is connected to both the 'Digital Processing Unit' and the 'RF Processing Unit' with arrows pointing towards them. + +**Figure 3-21: AIO White box Architecture Diagram** + +### 3.13.2 AIO Functional Module Description + +The AIO whitebox functional architecture comprises Digital Signal Processing, Connectivity (GbE) units, RF processing unit and Timing unit, as well as a timing unit as shown in Figure 3.13. The descriptions and requirements of functional module are as follows: + +#### **Digital Processing Unit** + +The digital Processing unit can be any GPP, FPGA or digital signal processor (DSP), with I/O chipset. It may also be in the form of System-On-Chip (SOC), or Multi-Chip Package (MCP). + +The digital Processing unit hosts L1/L2/L3 processing, ADC/DAC blocks and CFR/DPD blocks. The ADC and DAC are mixed signal devices responsible for conversion of data between the digital and analog domains. As such, this block can be included as part of the either the digital processing unit or the RF processing unit. + +#### **RF Processing Unit** + +The RF Processing Unit consists of an optional frequency converter (mixer), Power Amplifier (PA)/ Low Noise Amplifier (LNA) and TX/RX filters. + +#### 1     **Timing Unit** + +2     The timing unit includes any clock and frequency synthesis required as well as other timing and +3     synchronization circuits. + +#### 4     **Ethernet Controller** + +5     The Ethernet ports transport the backhaul traffic according to the gNB hardware node requirements. The +6     Ethernet device shall support GNSS/BDS based timing synchronization. + +#### 7     **3.13.3 AIO Interfaces** + +8     The AIO whitebox interfaces through backhaul with the 5GC core network. The backhaul interfaces are +9     typically implemented with GbE transport/connections. + +# Chapter 4 White Box Hardware Requirements + +This chapter provides the requirements for various white boxes used within the indoor picocell base station. These white boxes are O-CU, O-DU<sub>x</sub>, O-RU<sub>x</sub> and FHGW<sub>x</sub>. The O-CU and O-DU<sub>x</sub> can be implemented in an integrated fashion into one white box hardware or they can be separated. The reference design based on specification shall meet all these requirements. + +## 4.1 O-CU Requirements + +O-CU requirements are described in the following sections, which include the performance, interface, environmental, EMC, mechanical, thermal and power requirements. + +### 4.1.1 O-CU Performance + +The performance requirements of the O-CU are listed in Table 4-1. + +**Table 4-1 :O-CU Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|--------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------|----------| +| Synchronization | Support GPS Synchronization;<br>Support 1588V2 Synchronization<br>Support BeiDou Synchronization<br>Support BeiDou and GPS switching | Timing synchronization method | High | +| Supported DU Number | For O-CU/O-DU <sub>x</sub> integrated architecture: 1 | Number of O-DU <sub>x</sub> (s) connected to a single O-CU | High | +| | For O-CU/O-DU <sub>x</sub> non-integrated architecture: at least 8 | | High | +| Supported Cell Number | For O-CU/O-DU <sub>x</sub> integrated architecture: at least 4 | Cells supported by an O-CU | High | +| | For O-CU/O-DU <sub>x</sub> non-integrated architecture: at least 32 | | High | +| Supported RRC link number | For O-CU/O-DU <sub>x</sub> integrated architecture: at least 4800 | RLC links supported by O-CU | High | +| | For O-CU/O-DU <sub>x</sub> non-integrated architecture: at least 1280 | | High | +| Throughput between O-DU <sub>x</sub> | For O-CU/O-DU <sub>x</sub> integrated architecture: at least 6.5Gbps | Throughput between O-CU and O-DU <sub>x</sub> link | High | +| | For O-CU/O-DU <sub>x</sub> non-integrated architecture: at least 16Gbps | | High | +| Latency | TBD | O-CU latency | High | + +### 4.1.2 O-CU Interfaces + +The interface requirements of the O-CU are listed in Table 4-2: O-CU Interface Requirements. + +**Table 4-2: O-CU Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------|-------------------------------------------------------------------------------|---------------------------------------------------|----------| +| Transport Interface | At least 25 GbE F1 Interface to connect with O-DU <sub>x</sub> <sup>(a)</sup> | O-CU transport links to O-DU <sub>x</sub> and 5GC | High | +| | At least 10 GbE NG interface to connect with 5G core <sup>(b)</sup> | | High | +| | At least 25 GbE NG interface to connect with 5G core <sup>(a)</sup> | | High | + +Note: + +(a) This requirement is for separated architecture. + +(b) This requirement is for integrated architecture. For O-CU and O-DU<sub>x</sub> integrated solution, the F1 interface is an internal logic interface. + +### 4.1.3 O-CU Environmental and EMC + +The EMC requirements of the O-CU are listed in Table 4-3. + +**Table 4-3: O-CU EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------|-----------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| EMC | Complying with the requirements of 3GPP TS 38.113 (2017-12R15) [7] for equipment used in telecommunication room | Electromagnetic Compatibility requirement | High | +| Environment | The solution should comply with the requirements of O-RAN SuFG Circular economy guidelines on network equipment O-RAN.SuFG.CE [8] | Sustainability requirement | High | + +Note: For O-CU and O-DU<sub>x</sub> integrated solution, this requirement for O-CU portion is captured in the following O-DU<sub>x</sub> section. + +### 4.1.4 O-CU Mechanical, Thermal and Power + +The mechanical, thermal and power requirements of the O-CU are listed in the following tables. + +**Table 4-4: O-CU Mechanical Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------|----------| +| Dimension | Built in any 19" standard rack, or stand alone, with overall height of no more than 5U <sup>(a)</sup> , the depth (including the connector) must be less than 750mm. | Measurement in three dimensions | High | + +| | | | | +|----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------|------| +| Status Indicator LED | At least include the following status indicators:<br>1 indicating on/off status of the power supply<br>1 indicating on/off status of the transmission link | Indicator light | High | +|----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------|------| + +Note: + +- (a) Note that this dimension is application dependant and its value may change accordingly. + +**Table 4-5: O-CU Thermal Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------|----------| +| Reliability | Work steadily and reliably over a long period of time under the following environmental conditions:<br>Operating Temperature: - 5 °C ~ + 55 °C<br>Relative humidity: 15% ~ 85% | Environmental requirements for reliability | High | + +Note: For O-CU and O-DU<sub>x</sub> integrated solution, this requirement for O-CU portion is captured in the following O-DU<sub>x</sub> section. + +**Table 4-6: O-CU Power Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------|----------| +| Power Supply | DC -48 VDC (-40v ~ -57v) (can be connected to AC/DC converter) or AC 220V power supply, voltage range of 140V~ 300v, frequency range of 45Hz ~ 65Hz. | Power supply for O-CU | High | +| Power dissipation | < 300W full load operation | O-CU Power Requirement | High | + +Note: For O-CU and O-DU<sub>x</sub> integrated solution, this requirement for O-CU portion is captured in the following O-DU<sub>x</sub> section. + +## 4.2 O-DU<sub>x</sub> Common Requirements + +The O-DU<sub>x</sub> here takes the function of high PHY or whole PHY, OAM function and layer 2. Usually the hardware is placed in the machine room, which can be collocated in the coverage building or in the central machine room far away from the coverage building. + +### 4.2.1 O-DU<sub>x</sub> Performance + +The performance requirements of the O-DU<sub>x</sub> are listed in Table 4-7. + +**Table 4-7: O-DU<sub>x</sub> Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------|----------| +| Channel Bandwidth | Up to 100MHz (DL+UL) | RF Bandwidth | High | +| Antenna Number | 2T2R | Tx/Rx antenna number | High | +| | 4T4R | | High | +| Transmission distance | Directly connected with Fronthaul Gateway<br>$\geq 10\text{Km}$ | Distance between DU and FHGW <sub>x</sub> /RU | High | +| Connect Topology | Support at least two Fronthaul Gateways of chain topology connections | Fronthaul Gateway connection topology | High | +| Synchronization | Support GPS Synchronization;<br>Sync. between BS $\leq \pm 1.5\mu\text{s}$ ;<br><br>Carrier freq. error within one subframe $\leq \pm 0.1\text{ PPM}$<br>Support 1588V2 Synchronization<br>Support BeiDou Synchronization<br>Support BeiDou and GPS switching | Timing synchronization method | High | +| Capacity<br>MIMO | Support at least 4 100MHz bandwidth 2T2R cells | MIMO related capability | High | +| | Support at least 2 100MHz bandwidth 4T4R cells | | Low | +| | Support at least 8 100MHz bandwidth 2T2R cells | | Medium | +| | Support at least 4 100MHz bandwidth 4T4R cells | | High | +| | DL:2*2MIMO UL:2*2MIMO | | High | +| | DL:4*4MIMO UL:2*2MIMO | | High | +| Peak Rate | With 100MHz bandwidth and 74% for DL, the DL peak throughput of one cell shall not be lower than 850Mbps for 2*2 or 1700Mbps for 4*4, and the UL peak throughput of one cell shall not be lower than 190Mbps.(2T2R) | Peak data rate | High | +| Modulation | DL: QPSK,16QAM,64QAM,256QAM<br>UL: $\pi/2$ -bpsk, QPSK, 16QAM, 64QAM, 256QAM | Modulation schemes | High | + +| | | | | +|---------|------------------------------------------------------------------------------------------------------------|----------------------------|------| +| Latency | Control Plane<20ms, (def: message 1 to message 5)<br>User Plane DL <4ms, UL<6ms (def: PDCP SDU-> PDCP SDU) | Control/user plane Latency | High | +|---------|------------------------------------------------------------------------------------------------------------|----------------------------|------| + +### 4.2.2 O-DU<sub>x</sub> Interfaces + +The interface requirements of the O-DU<sub>x</sub> are listed in Table 4-8. + +**Table 4-8: O-DU<sub>x</sub> Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------|----------------------------------------------------------------------------|-----------------------------------|----------| +| Transport Interface | Fronthaul interfaces connected with either radio unit or Fronthaul Gateway | O-DU <sub>x</sub> transport links | High | +| | At least one NG interface to 5GC | | High | +| | At least 10 GbE F1 interface to connect with O-CU <sup>(a)</sup> | | High | + +Notes: + +(a) For O-CU and O-DU<sub>x</sub> that are separated physically + +### 4.2.3 O-DU<sub>x</sub> Environmental and EMC + +The EMC requirements of the O-DU<sub>x</sub> are listed in Table 4-9. + +**Table 4-9: O-DU<sub>x</sub> EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------|-----------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| EMC | Complying with the requirements of 3GPP TS 38.113 (2017-12R15) [7] for equipment used in telecommunication room | Electromagnetic Compatibility requirement | High | +| Environment | The solution should comply with the requirements of O-RAN SuFG Circular economy guidelines on network equipment O-RAN.SuFG.CE [8] | Sustainability requirement | High | + +### 4.2.4 O-DU<sub>x</sub> Mechanical, Thermal and Power + +The mechanical requirements of the O-DU<sub>x</sub> are listed in Table 4-10. + +**Table 4-10: O-DU<sub>x</sub> Mechanical Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------|----------| +| Dimension | Built in any 19" standard rack, or stand alone, and the height does not exceed 2U <sup>(a)</sup> , the depth (including the connector) must be less than 450mm. | Measurement in three dimensions | High | + +| | | | | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------|------| +| Status Indicator LED | At least includes the following status indicators:<br>1 indicating the on/off status of optical fiber interface<br>1 indicating off status of the power supply<br>1 indicating on/off status of the transmission link | Indicator light | High | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------|------| + +Note: + +(a) Note that this dimension is application dependant and its value may change accordingly. + +The thermal requirements of the O-DU<sub>x</sub> are listed in Table 4-11. + +**Table 4-11: O-DU<sub>x</sub> Thermal Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------|----------| +| Reliability | Work steadily and reliably over a long period of time under the following environmental conditions:<br>Operating Temperature: - 5 °C ~ + 55 °C<br>Relative humidity: 15% ~ 85% | Environmental requirements for reliability | High | + +The power requirements of the O-DU<sub>x</sub> are listed in Table 4-12. + +**Table 4-12: O-DU<sub>x</sub> Power Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------|-----------------| +| Power Supply | DC -48 VDC (-40v ~ -57v) (can be connected to AC/DC converter) or AC 220V power supply, voltage range of 140V~ 300v, frequency range of 45Hz ~ 65Hz. | Power supply for O-DU <sub>x</sub> | High | +| Power Dissipation | <del>< 500W, with 4 cells full load operation</del> | O-DU <sub>x</sub> Power Requirement | <del>High</del> | +| | < 350W, with 4 cells full load operation | | High | +| | < 800W, with 8 cells full load operation | | Medium | + +## 4.3 O-DU<sub>x</sub> Split Option Specific Requirements + +In addition to the common O-DU<sub>x</sub> requirements, there may be some specific requirements that apply to O-DU<sub>x</sub> due to the split option. These requirements are listed in the following sections. + +### 4.3.1 O-DU<sub>7-2</sub> Specific Requirements + +The specific requirements of O-DU<sub>7-2</sub> are listed in Table 4-13. + +**Table 4-13: O-DU<sub>7-2</sub> Specific Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------|-------------|-------------|----------| +|-----------|-------------|-------------|----------| + +| | | | | +|---------------------|-----------------------------------------------------------------|-----------------------------------------------|------| +| Transport Interface | At least 4 Ethernet interfaces connected with Fronthaul Gateway | O-DU <sub>7-2</sub> fronthaul transport links | High | +|---------------------|-----------------------------------------------------------------|-----------------------------------------------|------| + +1 +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 +16 +17 +18 +19 + +### 4.3.2 O-DU<sub>6</sub> Specific Requirements + +The specific requirements of O-DU<sub>6</sub> are listed in Table 4-14. + +**Table 4-14: O-DU<sub>6</sub> Specific Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------|------------------------------------------------|---------------------------------------------|----------| +| Transport Interface | At least one Ethernet interfaces for fronthaul | O-DU <sub>6</sub> fronthaul transport links | High | + +### 4.3.3 O-DU<sub>8</sub> Specific Requirements + +The specific requirements of the O-DU<sub>8</sub> are listed in Table 4-15. + +**Table 4-15: O-DU<sub>8</sub> Specific Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------|------------------------------------------------------------------------|---------------------------------------------|----------| +| Transport Interface | At least 4 CPRI (option 8) interfaces connected with Fronthaul Gateway | O-DU <sub>8</sub> fronthaul transport links | High | + +## 4.4 O-RU<sub>x</sub> Common Requirements + +The O-RU<sub>x</sub> common requirements apply to all the radio units regardless of the split option. In the indoor environment, O-RU<sub>x</sub> hardware is placed on the cell or wall of the coverage building; it converts the base band signal into RF signal or vice versa to supply the coverage. + +### 4.4.1 O-RU<sub>x</sub> Performance + +The O-RU<sub>x</sub> performance requirements cover all the aspects of radio unit including frequency bands, antenna configurations, power efficiency, etc. Table 4-16 lists the performance parameters related to O-RU<sub>x</sub>. + +Table 4-16: O-RU<sub>x</sub> Performance Requirements + +| Parameter | Requirement | Description | Priority | +|-----------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------|-------------------| +| Operating band | n2, n4, n5, n13, n41, n48, n66, n77, n78, n79 | Radio frequency band | High | +| Channel bandwidth | Up to 100MHz (DL+UL) | Frequency bandwidth | High | +| Transmitter and receiver number | 2T2R | Tx/Rx Antenna numbers | High | +| | 4T4R | | High | +| Output Power Accuracy | Under normal condition: $\pm 2$ dB | Power accuracy | High | +| Tx off Power Level | less than -89dBm/MHz | Tx power level | High | +| EVM at maximum output power | 64QAM: EVM smaller than 5%<br>256QAM: EVM smaller than 3.5% | Max output power | High | +| Operating band unwanted emissions | The Operating band unwanted emissions must satisfy the Category B limit defined by the section 6.6.4.2.4 in 3GPP TS 38.104 [3]. | RF operation band unwanted emissions requirement | High | +| Transmitter spurious emissions | The Operating band unwanted emissions must satisfy the Category B limit defined by the section 6.6.4.2.4 in [3]. | Deliberately generated RF signal by transmitter | High | +| receiver sensitivity | The throughput shall be $\geq 95\%$ of the maximum throughput of the reference measurement channel of G-FR1-A1-5, the reference sensitivity levels should not higher than -94dBm. | The weakest signal receiver is able to identify and process | High | +| Blocking | In Channel selection, ACS, In-band blocking, out-band blocking, IMD and other receiver specification must follow the 3GPP guidelines in [3], the reference sensitivity is allowed to degrade at most 6dB under all kinds of interference signal and corresponding level. | Channel selection related requirement | High | +| Other specifications | Except for all the RF specifications listed above, other RF specifications must follow the requirement in [3]. | Addition standard to comply | High | +| Downlink modulation Mode | QPSK、16-QAM、64-QAM、256-QAM | DL Modulation schemes | High | +| Uplink modulation mode | $\pi/2$ -BPSK、QPSK、16-QAM、64-QAM、256-QAM | UL Modulation schemes | High | +| | <del>256QAM</del> | | <del>medium</del> | + +| | | | | +|--------------|----------------------------------------------------------------|--------------------|------| +| Output power | The rated output power of the O-RU <sub>x</sub> is 0.5 W. 2T2R | RF radiation power | High | +| | The rated output power of the O-RU <sub>x</sub> is 1 W. 2T2R | | High | +| | The rated output power of the O-RU <sub>x</sub> is 1 W. 4T4R | | High | + +### 4.4.2 O-RU<sub>x</sub> Interfaces + +The interface related requirements of the O-RU<sub>x</sub> are listed in Table 4-17. + +**Table 4-17: O-RU<sub>x</sub> Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------------|------------------------------------------------------------------------------------------------------|---------------------------|----------| +| Interfaces Number | The O-RU <sub>x</sub> must have at least one fronthaul interface based on the split option supported | Number of fronthaul links | High | + +### 4.4.3 O-RU<sub>x</sub> Environmental and EMC + +The environmental and EMC requirements of the O-RU<sub>x</sub> are listed in Table 4-18. + +**Table 4-18: O-RU<sub>x</sub> Environmental and EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| Mounting method | Wall and ceiling mounting. | Mounting requirement | High | +| Grounding | The O-RU <sub>x</sub> must support Joint Grounding Method and can working normally when the grounding resistor is less than 10Ω. | Grounding requirement | High | +| EMC | Complying with the requirements of 3GPP TS 38.113 [7] | Electromagnetic Compatibility requirement | High | +| Environment | The solution should comply with the requirements of O-RAN SuFG Circular economy guidelines on network equipment O-RAN.SuFG.CE [8] | Sustainability requirement | High | + +### 4.4.4 O-RU<sub>x</sub> Mechanical, Thermal and Power + +The mechanical, thermal and power requirements of the O-RU<sub>x</sub> are listed in Table 4-19. + +**Table 4-19: O-RU<sub>x</sub> Mechanical, Thermal and Power Requirements** + +| Parameter | Requirement | Description | Priority | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------|----------| +| Weight | The gross weight of the O-RU <sub>x</sub> must smaller than 3kg. | Weight requirement | High | +| Dimension | The dimension of the O-RU <sub>x</sub> must smaller than 3L. | Measurement in dimension | High | +| Stability | The failure rate of O-RU <sub>x</sub> must not exceed 2% | Stability requirement | High | +| Power Consumption | At full load, the power consumption must not exceed 40W. 2T2R | Power requirement | High | +| | At full load, the power consumption must not exceed 50W. 4T4R | | High | +| Power supply | O-RU <sub>x</sub> must support either an isolated POE or isolated optical fiber with integrated power cable as the power supply source | Power Support Requirement | High | +| Level of protection | The protection level of O-RU <sub>x</sub> is equivalent to the IP31 standard. | Protection level | High | +| Temperature and moisture | The O-RU <sub>x</sub> must be operated and stored under those conditions:<br><br>Temperature : -5°C ~ +55°C<br><br>moisture : 5%~95% | Ambient temperature and moisture requirement | High | +| Atmospheric pressure | The O-RU <sub>x</sub> must operate normally under the atmospheric pressure between 70 to 106Kpa. | Operation atmospheric pressure requirement | High | +| Cooling mode | Natural heat dissipation. | System cooling requirement | High | + +1 + +## 4.5 O-RU<sub>x</sub> Split Option Specific Requirements + +Besides the common requirements which shall apply to all the radio unit types. The following sections list all the specific requirements that only apply to the designated split option. + +### 4.5.1 O-RU<sub>7-2</sub> Specific Requirements + +The O-RU<sub>7-2</sub> must have one RJ45 or SFP 10G Ethernet interface used as fronthaul interface. The O-RU<sub>7-2</sub> must support the lower physical layer functions and comply with [4]. + +### 4.5.2 O-RU<sub>6</sub> Specific Requirements + +The O-RU<sub>6</sub> must have at least one RJ45 10 gigabit per second (Gbps) Ethernet interface or at least one 10 Gbps optical interface. In some cases, depending on the fronthaul throughput associated with smaller air + +10 + +interface bandwidths, a 1 or 2.5 Gbps Ethernet or optical interface may be sufficient, depending on system operator requirements. SCF 5G nFAPI should be supported. + +At full load, the power consumption must not exceed the limit allowed by IEEE802.3at/PoE+, which is 25.5W. + +### 4.5.3 O-RU<sub>8</sub> Specific Requirements + +The O-RU<sub>8</sub> must have at least one SFP 10Gbps optical interface for CPRI interface. The O-RU<sub>8</sub> fronthaul interface shall comply with [5]. + +## 4.6 FHGW<sub>x</sub> – Common Requirements + +A Fronthaul gateway is used in many scenarios as the aggregation point of radio units, as well as to provide power to the O-RUs. The FHGW<sub>x</sub> usually is deployed close to O-RUs (e.g. indoor coverage: deployed on the same floor or in the same building with multiple radios less than 100 meters). FHGW<sub>x</sub> distributes traffic from the O-DU<sub>x</sub> to each O-RU<sub>x</sub>, and it combines the uplink traffic from all radios before sending it to the O-DU<sub>x</sub>. The benefit of using the FHGW<sub>x</sub> includes radio traffic aggregation and centralized power supplied to radio units. When different fronthaul interfaces are used by the O-DU<sub>x</sub> and O-RU<sub>x</sub>, the FHGW<sub>x</sub> can act as a fronthaul protocol converter, e.g. from eCPRI to CPRI. + +### 4.6.1 FHGW<sub>x</sub> Performance + +The performance requirements of the FHGW<sub>x</sub> are listed in Table 4-20. + +**Table 4-20: FHGW<sub>x</sub> Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------|----------| +| Transmission distance | The transmission distance must not less than 100m when using POE.<br><br>The transmission distance must not less than 200m when using optical fiber with power cable | Wired line distance limit | High | + +### 4.6.2 FHGW<sub>x</sub> Interfaces + +The interface requirements of the FHGW<sub>x</sub> are listed in Table 4-21. + +**Table 4-21: FHGW<sub>x</sub> Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------|----------| +| Interface | FHGW <sub>x</sub> must have at least 2 fronthaul interfaces, one for the connection with O-DU <sub>x</sub> , the other one for the connection with the second FHGW <sub>x</sub> . | Number of Fronthaul links | High | + +| | | | | +|---------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------|------| +| | FHGW <sub>x</sub> must support fronthaul connections for 8 O-RU <sub>x</sub> and must supply the power to the O-RU <sub>x</sub> through POE or optical fiber with power cable. | | High | +| Cascade | Each FHGW <sub>x</sub> must support a cascade connection with another fronthaul gateway. | Topology between FHGW <sub>x</sub> (s) | High | + +### 4.6.3 FHGW<sub>x</sub> Environmental, EMCs + +The EMC requirements of the FHGW<sub>x</sub> are listed in Table 4-22. + +**Table 4-22: FHGW<sub>x</sub> EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| Mounting method | Wall and ceiling mountable. | Mounting method | High | +| Grounding | The FHGW <sub>x</sub> must support Joint Grounding Method and can work normally when the grounding resistor is less than 10Ω. | FHGW <sub>x</sub> grounding requirement | High | +| EMC | Complying with the requirements in [7] for equipment used in telecommunication room | Electromagnetic Compatibility requirement | High | +| Environment | The solution should comply with the requirements of O-RAN SuFG Circular economy guidelines on network equipment O-RAN.SuFG.CE [8] | Sustainability requirement | High | + +### 4.6.4 FHGW<sub>x</sub> Mechanical, Thermal and Power + +The mechanical, thermal and power requirement of the FHGW<sub>x</sub> are listed in Table 4-23. + +**Table 4-23: FHGW<sub>x</sub> Mechanical, Thermal and Power Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------|----------| +| Power Consumption | The static power consumption (not supplying power to another FHGW <sub>x</sub> ) of each fronthaul gateway must not exceed 55W. | Power requirement | High | +| Dimension | Each FHGW <sub>x</sub> can be mounted on the 19-inch rack. The height must not exceed 1U. | Measurement in dimensions | High | +| Noise | Under Normal temperature (25°C) condition, the noise level must smaller than 40dBA. Under extreme condition (40°C), the noise level must smaller than 45dBA. | Noise level requirement | High | + +| | | | | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------|------| +| Temperature and moisture | The FHGW <sub>x</sub> must be operated and stored under these conditions:<br><br>Temperature : -5°C ~ +55°C<br><br>moisture : 15%~85% | Ambient temperature and moisture | High | +| Atmospheric pressure | The FHGW <sub>x</sub> must operate normally under the atmospheric pressure between 70 to 106Kpa. | Operational atmospheric pressure requirement | High | + +## 4.7 FHGW<sub>x</sub> – Split Option Specific Requirements + +For architecture with different split options, FHGW<sub>x</sub> may have specific hardware requirements that only apply to a designated type of fronthaul protocol. Those requirements are listed in the following sections. Note that Split option 6 does not require any FHGW. + +### 4.7.1 FHGW<sub>7-2</sub> Specific Requirements + +FHGW<sub>7-2</sub> must have at least two 10 Gbps optical or RJ45 Ethernet interfaces, one for the connection with O-DU<sub>7-2</sub>, the other for the connection with another FHGW<sub>7-2</sub>. + +Each FHGW<sub>7-2</sub> must support the connection to 8 O-RU<sub>7-2</sub> and supply the power to the O-RU<sub>7-2</sub> through POE or optical fiber with power cable. + +### 4.7.2 FHGW<sub>7-2->8</sub> Specific Requirements + +FHGW<sub>7-2->8</sub> must have at least two 10 Gbps optical or RJ45 Ethernet interfaces, one for the connection with O-DU<sub>7-2</sub>, the other for the connection with another FHGW<sub>7-2->8</sub>. + +Each FHGW<sub>7-2->8</sub> must support 8 connection links O-RU<sub>8</sub> and supply the power to the O-RU<sub>8</sub> through optical fiber with power cable. + +### 4.7.3 FHGW<sub>8</sub> Specific Requirements + +FHGW<sub>8</sub> must have at least 2 optical interfaces, one for the connection between O-DU<sub>8</sub>, the other for the connection with another FHGW<sub>8</sub>. + +Each FHGW<sub>8</sub> must support the 8 CPRI links for O-RU<sub>8</sub> and supply the power to O-RU<sub>8</sub> via optical fiber with power cable. + +## 4.8 Integrated gNB-DU Requirements + +The following sections list the requirements for the integrated gNB-DU which includes performance, interfaces, mechanical, thermal, etc. + +### 4.8.1 Integrated gNB-DU Performance + +Table 4-24 lists the performance requirements for gNB-DU. + +**Table 4-24: Integrated gNB-DU Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------|----------| +| Operating band | n2, n4, n5, n13, n41, n48, n66, n77, n78, n79, | Radio frequency band | High | +| Channel bandwidth | Up to 100MHz (DL+UL) | Frequency bandwidth | High | +| Transmitter and receiver number | 2T2R | Tx/Rx Antenna numbers | High | +| | 4T4R | | High | +| Output Power Accuracy | Under normal condition: $\pm 2$ dB | Power accuracy | High | +| Tx off Power Level | Less than -89dBm/MHz | Tx power level | High | +| EVM at maximum output power | 64QAM: EVM smaller than 5%<br>256QAM: EVM smaller than 3.5% | Max output power | High | +| Operating band unwanted emissions | The Operating band unwanted emissions must satisfy the Category B limit defined by the section 6.6.4.2.4 in [3]. | RF operation band unwanted emissions requirement | High | +| Transmitter spurious emissions | The Operating band unwanted emissions must satisfy the Category B limit defined by the section 6.6.4.2.4 in [3]. | Deliberately generated RF signal by transmitter | High | +| receiver sensitivity | The throughput shall be $\geq 95\%$ of the maximum throughput of the reference measurement channel of G-FR1-A1-5, the reference sensitivity levels should not higher than -94dBm. | The weakest signal receiver is able to identify and process | High | +| Blocking | In Channel selection, adjacent channel selectivity (ACS), In-band blocking, out-band blocking, Intermodulation Distortion (IMD) and other receiver specification must follow [3]; the reference sensitivity is allowed to degrade at most 6dB under all kinds of interference signal and corresponding level. | Channel selection related requirement | High | + +| | | | | +|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------|--------| +| Other specifications | Except for all the RF specifications listed above, other RF specifications must follow the requirement in [3]. | Addition standard to comply | High | +| Downlink modulation Mode | QPSK、16-QAM、64-QAM、256-QAM | DL Modulation schemes | High | +| Uplink modulation mode | $\pi/2$ -BPSK、QPSK、16-QAM、64-QAM | UL Modulation schemes | High | +| | 256QAM | | Medium | +| Output power | The rated output power of the O-RU <sub>x</sub> is 0.5W. 2T2R | RF radiation power | High | +| | The rated output power of the O-RU <sub>x</sub> is 1W. 2T2R | | High | +| | The rated output power of the O-RU <sub>x</sub> is 1W. 4T4R | | Low | +| Synchronization | Sync. between BS $\leq \pm 1.5\mu s$ ;<br>Carrier freq. error within one subframe $\leq \pm 0.1$ PPM<br>Support 1588V2 Synchronization<br>Support BeiDou Synchronization<br>Support GPS Synchronization;<br>Support BeiDou and GPS switching | Timing synchronization method | High | + +### 4.8.2 Integrated gNB-DU Interfaces + +Table 4-25 lists the Interface Requirement for integrated gNB-DU. + +**Table 4-25: Integrated gNB-DU Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------------|-----------------------------------------------------------------------|--------------------------|----------| +| Interfaces Number | The gNB-DU must have at least one Ethernet interface for F1 interface | Number of backhaul links | High | + +### 4.8.3 Integrated gNB-DU Environmental, EMC + +Table 4-26 lists the Environmental and electromagnetic compatibility (EMC) related requirements for integrated gNB-DU. + +**Table 4-26: Integrated gNB-DU Environmental and EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| Mounting method | Wall and ceiling mounting. | Mounting requirement | High | +| Grounding | The gNB-DU must support Joint Grounding Method and can operate normally when the grounding resistor is less than 10Ω. | Grounding requirement | High | +| EMC | Complying with the requirements of 3GPP TS 38.113 [7]. | Electromagnetic Compatibility requirement | High | +| Environment | The solution should comply with the requirements of O-RAN SuFG Circular economy guidelines on network equipment O-RAN.SuFG.CE [8] | Sustainability requirement | High | + +1 + +### 4.8.4 Integrated gNB-DU Mechanical, Thermal and Power + +Table 4-27 lists the mechanical, thermal and power requirements for integrated gNB-DU. + +**Table 4-27: Integrated gNB-DU Mechanical, Thermal and Power Requirements** + +| Parameter | Requirement | Description | Priority | +|--------------------------|--------------------------------------------------------------------------------------------------------------------------|----------------------------------|----------| +| Weight | The gross weight of the gNB-DU must be smaller than 3kg. | Weight requirement | High | +| Dimension | The dimension of the gNB-DU must be smaller than 3L. | Measurement in dimension | High | +| Stability | The failure rate of gNB-DU must not exceed 2% | Stability requirement | High | +| Power Consumption | At full load, the power consumption must not exceed 40W for 2T2R | Power requirement | High | +| | At full load, the power consumption must not exceed 50W for 4T4R | | High | +| Level of protection | The protection level of gNB-DU is equivalent to the IP31 standard. | Protection level | High | +| Temperature and moisture | The gNB-DU must be operated and stored under those conditions:<br><br>Temperature : -5°C~ +55°C<br><br>moisture : 5%~95% | Ambient temperature and moisture | High | +| Atmospheric pressure | The gNB-DU must operate normally under the atmospheric pressure between 70 to 106Kpa. | Operational atmospheric | High | + +| | | | | +|--------------|---------------------------|----------------------|------| +| | | pressure requirement | | +| Cooling mode | Natural heat dissipation. | Cooling method | High | + +## 4.9 AIO White Box Hardware Requirements + +This chapter provides the requirements of performance, interface, environmental, EMC, mechanical, thermal and power for AIO white box used within the Indoor Picocell base station. The reference design based on specification shall meet all these requirements based on their priority as specified by operators. + +### 4.9.1 AIO Performance + +The performance requirements of the AIO whitebox are listed in Table 4-28. + +**Table 4-28: AIO Whitebox Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------|----------| +| Synchronization | Support 1588v2 Synchronization | Timing synchronization method | Low | +| | Support GNSS Synchronization;<br>Synchronization Between BS $\le 1.5\mu\text{s}$ ; Carrier frequency error within one subframe $\le \pm 0.1$ PPM | | High | +| | Support BeiDou Synchronization | | High | +| | Sniffer Synchronization | | High | +| Peak Data Rate | DL: up to 750Mbps<br>UL: up to 340Mbps | Highest theoretical data rate in error free conditions. | High | +| Channel Bandwidth | $\le 300$ MHz OBW | RF Bandwidth | High | +| Antenna Configuration (Number of Transceivers) | 2T2R | Tx/Rx antenna number | High | +| Conducted Power | up to 27dBm per port | RF power | High | + +| | | | | +|-----------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------|------| +| Modulation | DL: QPSK, 16QAM, 64QAM, 256QAM<br>UL: $\pi/2$ -BPSK, QPSK, 16QAM, 64QAM, 256QAM | Modulation schemes | High | +| Operating band | n41/n78/n79 | Radio frequency band | High | +| Output Power Accuracy | The Output power accuracy shall satisfy the Category B limit defined by the section 6.2.2 in 3GPP TS 38.104 [3]. | Power accuracy | High | +| Tx off Power Level | less than -85dBm/MHz; See section 6.4.1.2 in 3GPP TS 38.104 [3]. | Tx power level during an off period | High | +| EVM at maximum output power | 64QAM: EVM smaller than 8%<br>256QAM: EVM smaller than 3.5% | Max output power | High | +| Operating band unwanted emissions | The Operating band unwanted emissions shall satisfy the limit defined by the section 6.6.4.2.4 in 3GPP TS 38.104 [3]. | RF operation band unwanted emissions requirement | High | +| Transmitter spurious emissions | The Operating band unwanted emissions shall satisfy the Category B limit defined by the section 6.6.5.2.1 and section 6.6.5.2.4 in [3]. | Deliberately generated RF signal by transmitter | High | +| Receiver Sensitivity | The throughput shall be $\geq 95\%$ of the maximum throughput of the reference measurement channel of G-FR1-A1-5; the reference sensitivity levels shall be better than -87.6dBm. | The weakest signal the receiver can identify and process | High | +| Blocking | In Channel selection, ACS, In-band blocking, out-band blocking, IMD and other receiver specification shall follow the 3GPP guidelines in [3], the reference sensitivity is allowed to degrade at most 6dB under all kinds of interference signal and corresponding level. | Channel selection related requirement | High | +| Other specifications | Except for all the RF specifications listed above, other RF specifications shall follow the requirement in [3]. | Additional standard to comply | High | + +### 4.9.2 AIO Interfaces + +The interface requirements of the AIO whitebox are listed in Table 4-29. + +**Table 4-29: AIO Whitebox Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------|----------------------------------------------------------------------------------------------|-------------------------------------|----------| +| Transport Interface | 1 GbE NG interface to connect with 5G core or<br>10 GbE NG interface to connect with 5G core | AIO whitebox transport links to 5GC | High | + +### 4.9.3 AIO Environmental and EMC + +**Table 4-30: AIO EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| EMC | Shall comply with the requirements of 3GPP TS 38.113 (2017-12 Rel-15) [7] for equipment used in telecommunication room | Electromagnetic Compatibility requirement | High | +| Mounting method | Ceiling, wall, desktop | Mounting requirement | High | +| Grounding | The AIO whitebox shall support Joint Grounding Method and shall work normally when the grounding resistor is less than 10Ω. | Grounding requirement | High | +| Environment | The solution should comply with the requirements of O-RAN SuFG Circular economy guidelines on network equipment O-RAN.SuFG.CE [8] | Sustainability requirement | High | + +### 4.9.4 AIO Mechanical, Thermal and Power + +The mechanical, thermal and power requirements of the AIO whitebox are listed in the following tables. + +**Table 4-31: AIO Mechanical Requirements** + +| Parameter | Requirement | Description | Priority | +|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------|----------| +| Dimensions | ≤2.5L | Measurement in three dimensions | Low | +| Weight | ≤2kg | Weight requirement | Low | +| Status Indicator LED | Shall include as a minimum the following status indicators:<br>---1 indicating on/off status of the power supply<br>---1 indicating on/off status of the transmission link | Indicator light | High | +| Reliability | The MTBF shall be >150000 hours | Mean Time Between Failures | High | + +**Table 4-32: Thermal Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------|-------------|-------------|----------| +|-----------|-------------|-------------|----------| + +| | | | | +|--------------------------|-----------------------------------------------------------------------------------------------------------|----------------------------------------------|------| +| Temperature and Humidity | The solution should support temperature range ( -5℃ ~ 45℃) and humidity (15%-85%) if implemented indoors. | Environmental requirements for reliability | High | +| Atmospheric pressure | The whitebox shall operate normally under atmospheric pressure between 70 to 106Kpa. | Operational atmospheric pressure requirement | High | +| Cooling mode | Passive cooling | System cooling requirement | High | +| Ingress protection | IP30 | Environmental requirements for protection | High | + +**Table 4-33: AIO Whitebox Power Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------------|------------------------|-------------------------------|----------| +| Power Supply | DC 12V with AC adaptor | Power supply Requirement | High | +| | PoE++ | Power supply Requirement | High | +| Power consumption | Up to 30W | Power consumption Requirement | High | \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/054b3c58df5f13334b3a14016c7f903a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/054b3c58df5f13334b3a14016c7f903a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ebe108017c2f26349431898494d7c6ec4953c9a8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/054b3c58df5f13334b3a14016c7f903a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:60cb99678b99d2ecd041b3227389fdf21c75b861920750f6253bb155c6cf2545 +size 4554 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/125103344bcdc340b14383188b5efc8d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/125103344bcdc340b14383188b5efc8d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b109cb455828d4f44767e4e1cf5ae5fd860b0d4d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/125103344bcdc340b14383188b5efc8d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c63664f17f44c9176cffdab35a799a06c9839b722aa6f387a8838220be76d29c +size 6332 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/139fc987a389075596746192ed692d94_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/139fc987a389075596746192ed692d94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..89254f07e1989f0f03b58a984f2f5fd5f59b8701 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/139fc987a389075596746192ed692d94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7f9df06fae9d9ecf87c6390054b41a42d9da3ea88aaeafa18a89f15964c3d9d7 +size 52747 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/2134194e3647ddc25ccdf3d168d151da_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/2134194e3647ddc25ccdf3d168d151da_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a4b376c3347fa399cda417e53de31683aa011b7b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/2134194e3647ddc25ccdf3d168d151da_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e1c185d3a97b5694b51e6355dc2fea92076addd12ffb0b25daa322cff4cd243 +size 12272 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/23d704ce76c94f51bf6fb76c920bf9fb_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/23d704ce76c94f51bf6fb76c920bf9fb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4b0c86f558b4b01f97b1ccc7f024ec6664e586ae --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/23d704ce76c94f51bf6fb76c920bf9fb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:16b9d4596eef6c457f5bc5d744b01196da29e8c46b04f406195e11714178a4d7 +size 40355 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/390534bd29d40567782170b486631969_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/390534bd29d40567782170b486631969_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f9844c448949205bf2e69817b1ec82532ac9c8b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/390534bd29d40567782170b486631969_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f3329c6bcdd1c3614c669dbb3896c52671fb4837cb4945875f22926b9d8f6638 +size 4498 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/390e6776641e490042a36d6ca17d5b4a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/390e6776641e490042a36d6ca17d5b4a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4b46dc1f49f2734a6e653b896fdad52421a5da98 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/390e6776641e490042a36d6ca17d5b4a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cb75d04bad7ca5655a488969a9036899306ad6394cd996abf221ea9550c46d7b +size 46240 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/3caaa9ddad1b4181d9068f1d16a87128_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/3caaa9ddad1b4181d9068f1d16a87128_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6d8dc523b4a64df266769ac09130a1017b8bd867 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/3caaa9ddad1b4181d9068f1d16a87128_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a121502c4c06538fa503572d5780a9c999aed6e71580fc6fe84e791b5cdb5270 +size 52804 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/4bce9508cd94ec490d1a520a585860ad_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/4bce9508cd94ec490d1a520a585860ad_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..743b95b64c50addccad8b00b37a308595010006b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/4bce9508cd94ec490d1a520a585860ad_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1a50ed74ba760402979ae73539a78feb7adad390900b72f43e6476290c1ce568 +size 39325 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/545cf03a7a687c0853f293b7d7b7ad46_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/545cf03a7a687c0853f293b7d7b7ad46_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bb2dde15c717b323e686c3f2e05968adb62595e1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/545cf03a7a687c0853f293b7d7b7ad46_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:db673e3cfa74158ab9662855e165422643db88103c94a86ee64b4290ebcecb1a +size 50899 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/557182a42e2ab26ed00c8d6ea5ae6792_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/557182a42e2ab26ed00c8d6ea5ae6792_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7febaf160800616c642cc839d8d2973308592ee2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/557182a42e2ab26ed00c8d6ea5ae6792_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:28bc9e2cbb3ab9983439f2a12180b5a2182b5208a9f114a96de77e8f7c92b3bf +size 46667 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/592e391868768a094012c09fd995f741_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/592e391868768a094012c09fd995f741_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..93d091d2f515ff7600861630cd16d6d987448063 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/592e391868768a094012c09fd995f741_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:216ddd2b066e3880aec42c604b6d49c8df299ab4194f3831ef87fa455bb49ecb +size 35070 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/5f84545e67bb6c7a4851155ad2beffa6_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/5f84545e67bb6c7a4851155ad2beffa6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bb9c67116fd9588c9f69e48bd4cea970be8f600d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/5f84545e67bb6c7a4851155ad2beffa6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7f570a81f92425255c59920ba2e54208c7d72c56f0096d4d8db895fffc167e7e +size 7079 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/62de953afabdbfd2feecce810b32384f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/62de953afabdbfd2feecce810b32384f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..202d837a8ba9288076079170c3607e1bf308b57a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/62de953afabdbfd2feecce810b32384f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:85c26c7108cd76331e2a774e9b63f87b74c7488e2fdeb2cdbc2517028da7af16 +size 98522 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/65aa1ef346b00831174a2929ec75b255_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/65aa1ef346b00831174a2929ec75b255_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..23c555838e64f9422fd59a4387a026f1100a5ee0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/65aa1ef346b00831174a2929ec75b255_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ed5bf314e7eae66fb9597ff161823ba75e318c029e5c59379b79895acb55a9d +size 4517 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/7874a37ff237673b53664e8c1175e334_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/7874a37ff237673b53664e8c1175e334_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..84ee15fd48e7ef7232ddabce125d1e916e39f1e8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/7874a37ff237673b53664e8c1175e334_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6cc6f7cece91e0bffca774d2e2e5a4157b63cc65185d3613904aaaf4f556ca11 +size 41052 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/7c6b06d2acb53bf83c357242d4189aca_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/7c6b06d2acb53bf83c357242d4189aca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..05d46d82ad1d37b96a152792760732f1e94a13a4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/7c6b06d2acb53bf83c357242d4189aca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cccb860a012ed41fd3d7efdfa06b25af3e646839ce6765649b2562662db9b56d +size 30369 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/87cd62e9b693b0928b9a8820de214c51_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/87cd62e9b693b0928b9a8820de214c51_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0eec9b6e721f68bd1c6f552032e4e42a8d2b7a24 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/87cd62e9b693b0928b9a8820de214c51_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c506c41ca0eae66c13a9a75100dc8ab2038c8f3fb40e66ffbba7fbf01c6b36bb +size 7581 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/8ae1533a68bdd4424daa4802fa482a00_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/8ae1533a68bdd4424daa4802fa482a00_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5e2978ab1557b08a9f76eaa083cf7bb0311f80df --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/8ae1533a68bdd4424daa4802fa482a00_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2708886f71b1bbfa0dc9cc503b24d25b9b7b0bf632850d2fe359b53526a556f1 +size 25959 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/960998b29702d84d1604164abdc6c72d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/960998b29702d84d1604164abdc6c72d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..11db21693ce1af03c446ebb3f35538f7346de6ae --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/960998b29702d84d1604164abdc6c72d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:877f6932ca18d94d00fc29d334f919f19428f043ddf5223e853b4c6a0d0f9125 +size 4543 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/9fca8855118cd18bf90d5c28d5985afe_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/9fca8855118cd18bf90d5c28d5985afe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..334ea1cd43c993f56eabc75991fd398e68e976ab --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/9fca8855118cd18bf90d5c28d5985afe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6dd0d2c4685e655d2a567bec04eaea60979c16b88c3f2c2c53600cf318e1c65e +size 4567 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/a416367a20358b4e83fff769d83c8e7c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/a416367a20358b4e83fff769d83c8e7c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1e5a7e121b6e973a57c9c1d4dec20899003fddef --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/a416367a20358b4e83fff769d83c8e7c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:939b695c67cac4758fc7bbcddd7d66bf1ab73ac4cb81d67cf8b48d2b35dce77c +size 4431 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/a664db818cf6b83e6c9b666480475dc5_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/a664db818cf6b83e6c9b666480475dc5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..58800572478549c5cd6a073887f2f99bf02dfda7 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/a664db818cf6b83e6c9b666480475dc5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:75f88dae2fc5b98622beb30b434272410ca0cc46fc91f85568431640926072fe +size 43967 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/a95a42e29d7d56bada4fa7008e477284_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/a95a42e29d7d56bada4fa7008e477284_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9862d2615d1ce96ee303f07946e152e4d4e2d32b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/a95a42e29d7d56bada4fa7008e477284_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:831f0434733dd19519c078e03629d999a617a9cefafc28f7e58aac4e95fa5959 +size 83046 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/aaeb27559097506a79108d8f75b07b39_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/aaeb27559097506a79108d8f75b07b39_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..65f4bdef6e6208a866c2ca159d43efaa4f6e6827 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/aaeb27559097506a79108d8f75b07b39_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab396adefba746d4cf13c1e4735c121769924814120dfded10a9e5177b79e191 +size 4538 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/aca351afa0e2ac2da016b2b865c195af_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/aca351afa0e2ac2da016b2b865c195af_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..102c3c04fa46f85ea1851e6c039ddc0383026a86 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/aca351afa0e2ac2da016b2b865c195af_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aed68259bff9718c3bd0f8b9542e8f1533150a400ed590690d31b82c80d389e0 +size 67422 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/c2dd92b45cb22fca374be8d1719d4419_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/c2dd92b45cb22fca374be8d1719d4419_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fabbca071b6a30f8683b9ecdbc73588c26afc5a5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/c2dd92b45cb22fca374be8d1719d4419_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:872723d4fe4ab70e370159a326df4a3305d73a6107a199957eba87e18a503cf1 +size 26048 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/cb627a044994cc58cd56604ea8eec02d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/cb627a044994cc58cd56604ea8eec02d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3b35ade5b3ac2d9f267dfcf3100a183653d43a75 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/cb627a044994cc58cd56604ea8eec02d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ddad769dd5175d95653d2437fa84f9b17dca210e70b05b75891cd2530b627985 +size 44305 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/cb663b50226a01a39179e5f2205a5a7d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/cb663b50226a01a39179e5f2205a5a7d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3662e147cd6f88c7ed57b39b20725d390f8a4a11 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/cb663b50226a01a39179e5f2205a5a7d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c376d30952b7c223c712306fc1dfff5c194cd7cef1f398da9b51e02ec8355240 +size 28944 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/cec5898472d1b411c005dcd7105103b4_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/cec5898472d1b411c005dcd7105103b4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7f725755837fe011d9686085c73cf7037d78c75 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/cec5898472d1b411c005dcd7105103b4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:231232d617f16eb309ba7da7ebeb7c5d3d25822f5ce79fc3a0dca0225f903d84 +size 56588 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/e10258aabb03161bf61f6ee998e17607_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/e10258aabb03161bf61f6ee998e17607_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f872f7da607aa4768ba660f303a209d4efd56893 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/e10258aabb03161bf61f6ee998e17607_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8a67e6a843e5c59118193eb4b3451231c6b9139c52814c1bc1d6d29eed6e308 +size 4544 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/fdc337dc012d39a1c7ea2f2f5be1e9b2_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/fdc337dc012d39a1c7ea2f2f5be1e9b2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f487eea681b296cc694cfd30ab2edc38aa311b17 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/fdc337dc012d39a1c7ea2f2f5be1e9b2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5cd9612eb03524fb6149157ccc7fde8cbeeca9e406420984057721e54a12f216 +size 6319 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/raw.md b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..4aa4fc9d23a15a1229d7df6446cbaaa4bdf65402 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00/raw.md @@ -0,0 +1,1103 @@ + + +# **O-RAN White Box Hardware Working Group Hardware Reference Design Specification for Indoor Pico Cell with Fronthaul Split Option 6** --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN White Box Hardware Working Group Hardware Reference Design Specification for Indoor Pico Cell with Fronthaul Split Option 6** --- + +Copyright © 2021 by the O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +1 + +# --- Revision History + +2 + +| Date | Revision | Author | Description | +|------------|----------|--------|-------------------------------| +| 2021.07.08 | 02.00 | WG7 | Final version for publication | + +3 + +4 + +# Contents + +| | | | +|----|------------------------------------------------------------------|----| +| 1 | Revision History ..... | 2 | +| 3 | Chapter 1 Introductory Material ..... | 6 | +| 4 | 1.1 Scope ..... | 6 | +| 5 | 1.2 References ..... | 6 | +| 6 | 1.3 Definitions and Abbreviations ..... | 7 | +| 7 | 1.3.1 Definitions..... | 7 | +| 8 | 1.3.2 Abbreviations ..... | 7 | +| 9 | Chapter 2 Hardware Reference Design ..... | 10 | +| 10 | 2.1 O-CU Hardware Reference Design ..... | 10 | +| 11 | 2.2 O-DU Hardware Reference Design ..... | 10 | +| 12 | 2.2.1 O-DU High-Level Functional Block Diagram ..... | 10 | +| 13 | 2.2.2 O-DU <sub>6</sub> Hardware Components..... | 11 | +| 14 | 2.2.2.1 Digital Processing Unit..... | 11 | +| 15 | ➤ Memory Channel Interfaces..... | 12 | +| 16 | ➤ PCIe ..... | 12 | +| 17 | ➤ Ethernet..... | 12 | +| 18 | 2.2.2.2 Hardware Accelerator..... | 13 | +| 19 | 2.2.3 Synchronization and Timing..... | 13 | +| 20 | 2.2.3.1 Synchronization and Timing Design 1 ..... | 13 | +| 21 | 2.2.4 External Interface Ports..... | 14 | +| 22 | 2.2.5 Mechanical ..... | 15 | +| 23 | ➤ Mother Board..... | 15 | +| 24 | ➤ Cooling ..... | 17 | +| 25 | 2.2.6 Power Unit ..... | 17 | +| 26 | 2.2.7 Thermal ..... | 18 | +| 27 | 2.2.8 Environmental and Regulations ..... | 18 | +| 28 | 2.3 O-RU <sub>6</sub> Hardware Reference Design ..... | 18 | +| 29 | 2.3.1 O-RU <sub>6</sub> High-Level Functional Block Diagram..... | 19 | +| 30 | 2.3.2 O-RU <sub>6</sub> Hardware Components..... | 19 | +| 31 | 2.3.3 O-RU <sub>6</sub> Functional Module Description..... | 20 | +| 32 | 2.3.3.1 Network Processing Unit (NPU) ..... | 21 | +| 33 | 2.3.3.1.1 Networking I/O..... | 21 | +| 34 | 2.3.3.1.2 Low-speed connectivity and boot ..... | 22 | +| 35 | 2.3.3.1.3 DDR..... | 23 | +| 36 | 2.3.3.1.4 Processor subsystem ..... | 24 | +| 37 | 2.3.3.1.5 Modem I/O..... | 24 | +| 38 | 2.3.3.1.6 Security ..... | 25 | +| 39 | 2.3.3.2 PHY Layer ASIC..... | 25 | +| 40 | 2.3.3.3 RF Front End ..... | 27 | +| 41 | 2.3.3.4 Power Management ..... | 27 | +| 42 | 2.3.4 Synchronization and Timing ..... | 28 | +| 43 | 2.3.4.1 Hardware Requirements ..... | 28 | + +| | | | | +|----|---------|--------------------------------------------------------|----| +| 1 | 2.3.4.2 | Synchronization and Timing Design 1 ..... | 28 | +| 2 | 2.3.4.3 | Synchronization and Timing Design 2 ..... | 29 | +| 3 | 2.3.5 | External Interface Ports..... | 30 | +| 4 | 2.3.6 | Power Unit ..... | 30 | +| 5 | 2.3.7 | Environmental and Regulations ..... | 31 | +| 6 | 2.4 | Integrated gNB-DU Reference Design Solution..... | 31 | +| 7 | 2.4.1 | Power Unit ..... | 32 | +| 8 | 2.4.1.1 | Power Management..... | 32 | +| 9 | 2.4.2 | Synchronization and Timing..... | 32 | +| 10 | 2.4.3 | External Interface Ports..... | 32 | +| 11 | 2.4.4 | Power Unit ..... | 32 | +| 12 | 2.4.5 | Environmental and Regulations ..... | 32 | +| 13 | 2.5 | FHGW Hardware Reference Design ..... | 32 | +| 14 | | Annex 1: Example Hardware Bill of Materials ..... | 33 | +| 15 | | Annex 2: ..... | 35 | +| 16 | | Annex ZZZ: O-RAN Adopter License Agreement ..... | 36 | +| 17 | | Section 1: DEFINITIONS ..... | 36 | +| 18 | | Section 2: COPYRIGHT LICENSE ..... | 37 | +| 19 | | Section 3: FRAND LICENSE ..... | 37 | +| 20 | | Section 4: TERM AND TERMINATION..... | 38 | +| 21 | | Section 5: CONFIDENTIALITY ..... | 38 | +| 22 | | Section 6: INDEMNIFICATION ..... | 38 | +| 23 | | Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 39 | +| 24 | | Section 8: ASSIGNMENT ..... | 39 | +| 25 | | Section 9: THIRD-PARTY BENEFICIARY RIGHTS..... | 39 | +| 26 | | Section 10: BINDING ON AFFILIATES ..... | 39 | +| 27 | | Section 11: GENERAL ..... | 39 | + +28 + +# 29 Tables + +| | | | +|----|----------------------------------------------|----| +| 30 | Table 2-1: Processor Feature List..... | 11 | +| 31 | Table 2-2: Memory Channel Feature List ..... | 12 | +| 32 | Table 2-3 External Port List ..... | 14 | +| 33 | Table 2-4 Power Supply Features..... | 18 | +| 34 | | | + +# 35 Figures + +| | | | +|----|-----------------------------------------------------------|----| +| 36 | Figure 2-1 O-DU <sub>6</sub> Architecture Diagram ..... | 11 | +| 37 | Figure 2-2 Digital Processing Unit Block Diagram ..... | 13 | +| 38 | Figure 2-3 O-DU <sub>6</sub> Timing Synchronization ..... | 14 | + +| | | | +|----|----------------------------------------------------------------------------------------------|----| +| 1 | Figure 2-4 Mother Board Layout ..... | 16 | +| 2 | Figure 2-5 Chassis Mechanical Diagram ..... | 17 | +| 3 | Figure 2-6 General Block Diagram for O-RU <sub>6</sub> ..... | 19 | +| 4 | Figure 2-7 O-RU <sub>6</sub> Architecture Diagram ..... | 19 | +| 5 | Figure 2-8 O-RU <sub>6</sub> Functional Module Diagram..... | 20 | +| 6 | Figure 2-9 Sub-6 GHz Indoor Pico O-RU <sub>6</sub> Functional Modules (Split Option 6) ..... | 21 | +| 7 | Figure 2-10 O-RU <sub>6</sub> Networking I/O..... | 22 | +| 8 | Figure 2-11 O-RU <sub>6</sub> SFP Connectivity ..... | 22 | +| 9 | Figure 2-12 O-RU <sub>6</sub> Low-speed NPU Connectivity ..... | 23 | +| 10 | Figure 2-13 O-RU <sub>6</sub> DDR..... | 24 | +| 11 | Figure 2-14 O-RU <sub>6</sub> Modem I/O ..... | 24 | +| 12 | Figure 2-15 O-RU <sub>6</sub> NPU Security ..... | 25 | +| 13 | Figure 2-16 O-RU <sub>6</sub> PHY ASIC block diagram ..... | 26 | +| 14 | Figure 2-17 O-RU <sub>6</sub> 5G Modem Subsystem..... | 27 | +| 15 | Figure 2-18 Timing Modules..... | 28 | +| 16 | Figure 2-19 Ethernet Synchronization I ..... | 29 | +| 17 | Figure 2-20 Ethernet Synchronization II ..... | 30 | +| 18 | Figure 2-21 Sub-6 GHz Indoor Pico Integrated O-DU&O-RU Functional Modules ..... | 31 | +| 19 | Figure A-1: Sub-6 Split (O-RU <sub>6</sub> ) and Integrated Picocell Reference Design ..... | 33 | +| 20 | | | +| 21 | | | + +# Chapter 1 Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN ALLIANCE. + +In the main body of this specification (in any “chapter”) the information contained therein is informative, unless explicitly described as normative. Information contained in an “Annex” to this specification is always informative unless otherwise marked as normative. + +The contents of the present document are subject to continuing work within O-RAN WG7 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN ALLIANCE with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. This variable is for internal WG7 use only. + +The present document specifies system requirements and high-level architecture for the Indoor Pico Cell Hardware Reference Design with Fronthaul Split Option 6 deployment scenario as specified in the Deployment Scenarios and Base Station Classes document [1]. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- [1] ORAN-WG7.DSC.0-V01.00 Technical Specification, Deployment Scenarios and Base Station Classes for White Box Hardware +- [2] 3GPP TR 21.905: Vocabulary for 3GPP Specifications +- [3] 3GPP TR 38.104: NR; Base Station (BS) radio transmission and reception +- [4] 3GPP TR 38.913: Study on Scenarios and Requirements for Next Generation Access Technologies +- [5] 3GPP TS 38.401: NG-RAN; Architecture description +- [6] ORAN-WG7.IPC.HAR-v01.00 Technical Specification: O-RAN Indoor Pico Cell Hardware Architecture and Requirement Specification +- [7] SCF 222.10.03: 5G FAPI PHY API Specification +- [8] SCF 082.09.05: nFAPI and FAPI Specifications +- [9] SCF 223.10.02: RF and Digital Front End Control API + +[10] SCF 224.10.01: 5G FAPI Network Monitor Mode API + +[11] SCF 225.2.0: 5G nFAPI Specifications [https://scf.io/en/documents/225\\_5G\\_nFAPI\\_specifications.php](https://scf.io/en/documents/225_5G_nFAPI_specifications.php) + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [2]. For the base station classes of Pico, Micro and Macro, the definitions are given in 3GPP TR 38.104 [3]. + +**Carrier Frequency:** Center frequency of the cell. + +**F1 interface:** The open interface between O-CU and O-DU defined by 3GPP TS 38.473. + +**Integrated architecture:** In the integrated architecture, the O-RU and O-DU are implemented on one platform. Each O-RU and RF front end is associated with one O-DU. They are then aggregated to O-CU and connected by F1 interface. + +**Split architecture:** The O-RU and O-DU are physically separated from one another in this architecture. A switch may aggregate multiple O-RUs to one O-DU. O-DU, switch and O-RUs are connected by the fronthaul interface. + +**Transmission Reception Point (TRxP):** Antenna array with one or more antenna elements available to the network located at a specific geographical location for a specific area. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in [2] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, as in [2]. + +| | | +|-------|-----------------------------------------------------------------| +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth-Generation Mobile Communications | +| ADC | Analog to Digital Converter | +| ASIC | Application Specific Integrated Circuit | +| BS | Base Station | +| CFR | Crest Factor Reduction | +| CISPR | Comité International Spécial des Perturbations Radioélectriques | +| CU | Centralized Unit as defined by 3GPP | +| DAC | Digital to Analog Converter | +| DDC | Digital Down Conversion | +| DDR | Double Data Rate | +| DL | Downlink | +| DPD | Digital Pre-Distortion | + +| | | | +|----|-------------------|-------------------------------------------------------------------| +| 1 | DPU | Digital Processing Unit | +| 2 | DSP | Digital Signal Processor | +| 3 | DU | Distributed Unit as defined by 3GPP | +| 4 | DUC | Digital Up Conversion | +| 5 | ECC | Error-Correcting Code | +| 6 | FAP | Functional Application Platform Interface | +| 7 | FCC | Federal Communications Commission | +| 8 | FDD | Frequency Division Duplex | +| 9 | FFT | Fast Fourier Transform | +| 10 | FH | Fronthaul | +| 11 | FHGW | Fronthaul Gateway | +| 12 | FPGA | Field Programmable Gate Array | +| 13 | GbE | Gigabit Ethernet | +| 14 | GMC | Grand Master Clock | +| 15 | GNSS | Global Navigation Satellite System | +| 16 | GPS | Global Positioning System | +| 17 | HSUART | High-Speed Universal Asynchronous Receiver/Transmitter | +| 18 | IEEE | Institute of Electrical and Electronics Engineers | +| 19 | IMC | Integrated Memory Controller | +| 20 | I/O | Input/Output | +| 21 | JTAG | Joint Test Action Group | +| 22 | L2 | Layer 2 | +| 23 | L3 | Layer 3 | +| 24 | LDPC | Low-Density Parity-Check | +| 25 | LTE | Long Term Evolution | +| 26 | LRDIMM | Load-Reduced Dual In-Line Memory Module | +| 27 | MAC | Media Access Control | +| 28 | MIMO | Multiple Input Multiple Output | +| 29 | MCP | Multi-Chip Package | +| 30 | MU-MIMO | Multiple User MIMO | +| 31 | nFAP | network Functional Application Platform Interface | +| 32 | NFV | Network Function Virtualization | +| 33 | NMEA | National Marine Electronics Association | +| 34 | NPU | Network Processing Unit | +| 35 | NR | New Radio | +| 36 | O-CU | O-RAN Centralized Unit as defined by O-RAN | +| 37 | O-DU <sub>6</sub> | A specific O-RAN Distributed Unit having fronthaul split option 6 | +| 38 | O-RU <sub>6</sub> | A specific O-RAN Radio Unit having fronthaul split option 6 | +| 39 | PCIe | Peripheral Component Interface Express | +| 40 | PCH | Platform Controller Hub | +| 41 | PDCP | Packet Data Convergence Protocol | +| 42 | PHY | Physical layer | +| 43 | PLL | Phase Locked Loop | +| 44 | PMBus | Power Management Bus | + +| | | | +|----|-------|---------------------------------------------| +| 1 | PoE | Power over Ethernet | +| 2 | PWM | Pulse Width Modulation | +| 3 | RAN | Radio Access Network | +| 4 | RDIMM | Registered Dual In-Line Memory Module | +| 5 | RFFE | Radio Frequency Front End | +| 6 | RGMII | Reduced Gigabit Media-Independent Interface | +| 7 | RF | Radio Frequency | +| 8 | RFFE | RF Front End | +| 9 | RoHS | Restriction of Hazardous Substances | +| 10 | RU | Radio Unit as defined by 3GPP | +| 11 | RX | Receiver | +| 12 | SFP | Small Form-factor Pluggable | +| 13 | SFP+ | Small Form-factor Pluggable Transceiver | +| 14 | SOC | System On Chip | +| 15 | SPI | Serial Peripheral Interface | +| 16 | TDP | Thermal Design Power | +| 17 | TR | Technical Report | +| 18 | TS | Technical Specification | +| 19 | TX | Transmitter | +| 20 | UART | Universal Asynchronous Receiver/Transmitter | +| 21 | UL | Uplink | +| 22 | USB | Universal Serial Bus | +| 23 | WG | Working Group | +| 24 | | | +| 25 | | | + +# Chapter 2 Hardware Reference Design + +## 2.1 O-CU Hardware Reference Design + +The O-CU white box is the hardware platform that performs the CU function of upper L2 and L3. The hardware systems specified in this document meet the computing, power and environmental requirements for O-RAN deployment scenarios. These requirements are described in the hardware requirement specification as well as in the deployment scenarios. The O-CU hardware includes the chassis platform, mother board, peripheral devices and cooling devices. The mother board contains processing unit, memory, the internal I/O interfaces, and external connection ports. The midhaul and backhaul interfaces are used to carry the traffic between O-CU and O-DU<sub>6</sub> as well as O-CU and core network. Other hardware functional components include storage for software, debugging interfaces, and board management controller just to name a few. The O-CU designer will make decisions based on the specific needs of the implementation. + +As discussed in the hardware architecture requirements [6], the O-CU white box hardware is similar to O-DU<sub>6</sub> on interfaces and processing unit. Rather than specifying a dedicated O-CU reference design, we reuse O-DU<sub>6</sub> hardware reference design for O-CU. + +## 2.2 O-DU Hardware Reference Design + +The terms “O-DU<sub>6</sub>” and “O-RU<sub>6</sub>” are used here for O-DU and O-RU that use split option 6. O-DU<sub>6</sub> hardware systems specified in this document meet the computing, power and environmental requirements of the indoor picocell deployment scenario configuration. The O-DU<sub>6</sub> hardware includes the chassis platform, mother board, peripheral devices and cooling devices. The mother board contains processing unit, memory, the internal I/O interfaces, and external connection ports. The front haul and back haul interface are used to carry the traffic between O-DU<sub>6</sub> and O-RU<sub>6</sub> as well as O-CU and O-DU<sub>6</sub>. + +The O-DU<sub>6</sub> white box is the hardware platform that performs MAC functions while PHY is done in the O-RU<sub>6</sub>. The O-DU<sub>6</sub> design may also provide an interface for hardware accelerator(s) if that option is preferred. However, this design does not specify accelerator hardware. Other hardware functional components include storage for software, debugging interfaces, and board management controller. The O-DU<sub>6</sub> designer will make decisions based on the specific needs of the implementation. + +Note that the O-DU<sub>6</sub> HW reference design is also reusable for O-CU and integrated O-CU/ O-DU<sub>6</sub>. + +### 2.2.1 O-DU High-Level Functional Block Diagram + +O-DU<sub>6</sub> and O-RU<sub>6</sub> are connected via nFAPI interfaces over fiber/ethernet transport. With an option 6 MAC/PHY fronthaul split, the O-RU<sub>6</sub> includes complete physical layer processing functions and + +the O-DU<sub>6</sub> handles higher layer processing functions. The O-DU<sub>6</sub> hardware architecture is shown in **Error! Reference source not found..** Note that O-DU<sub>6</sub> does not require an accelerator module since physical layer functions are handled by O-RU<sub>6</sub>. + +![Figure 2-1 O-DU6 Architecture Diagram. The diagram shows the internal structure of the O-DU6 and its connection to the O-RU6. The O-DU6 block contains an Ethernet Interface (IEEE1588) connected to a Digital Processing Unit, which is in turn connected to another Ethernet Interface (IEEE1588). This second Ethernet Interface is connected to the O-RU6 block via an nFAP1 FH Interface. The O-RU6 block contains an Ethernet Interface (IEEE1588) and a Hi+Low Phy block.](23d704ce76c94f51bf6fb76c920bf9fb_img.jpg) + +``` + +graph LR + subgraph O-DU6 + EI1[Ethernet Interface IEEE1588] <--> DPU[Digital Processing Unit] + DPU --> EI2[Ethernet Interface IEEE1588] + end + EI2 <-->|nFAP1 FH Interface| EI3[Ethernet Interface IEEE1588] + subgraph O-RU6 + EI3 <--> HLP[Hi+Low Phy] + end + +``` + +Figure 2-1 O-DU6 Architecture Diagram. The diagram shows the internal structure of the O-DU6 and its connection to the O-RU6. The O-DU6 block contains an Ethernet Interface (IEEE1588) connected to a Digital Processing Unit, which is in turn connected to another Ethernet Interface (IEEE1588). This second Ethernet Interface is connected to the O-RU6 block via an nFAP1 FH Interface. The O-RU6 block contains an Ethernet Interface (IEEE1588) and a Hi+Low Phy block. + +Figure 2-1 O-DU<sub>6</sub> Architecture Diagram + +### 2.2.2 O-DU<sub>6</sub> Hardware Components + +The sections below describe the functionality, interface and performance for each respective block of the O-DU<sub>6</sub>. As device integration is an ongoing activity, chip boundaries may be fluid and some functionalities may move from one block to another or entire functionalities may be absorbed into other blocks. The sections below describe the functional blocks independent of which physical device they may reside in. + +#### 2.2.2.1 Digital Processing Unit + +##### a. Digital Processing Unit Requirement + +General purpose processor performance and other related information are listed in Table 2-1. + +Table 2-1: Processor Feature List + +| Item Name | Description | +|--------------------------------------------|-------------| +| # of Cores | 16 | +| # of Threads | 32 | +| Base Frequency | 2.20 GHZ | +| Max Turbo Frequency | 3.00 GHz | +| Cache | 22 MB | +| TDP | 100W | +| Max Memory Size (dependent on memory type) | 512 GB | +| Memory Types | DDR4 | +| Max # of Memory Channels | 4 | + +###### Interfaces + +The interface specification in main board are as follows: + +###### ➤ Memory Channel Interfaces + +The system memory capacity, type and related information are described in Table 2-2. + +**Table 2-2: Memory Channel Feature List** + +| Item Name | Description | +|----------------------|-------------------------| +| Memory Types | DDR4 | +| # of Memory Channels | 4 | +| ECC LRDIMM | Up to 512GB | +| ECC RDIMM | Up to 256GB | +| Memory Speed | 2666/2400/2133MHz | +| DIMM Sizes | 128GB, 64GB, 32GB, 16GB | +| Memory Voltage | 1.2 V | + +###### ➤ PCIe + +PCIe Gen 3 is supported by the processor. There are a total of 32 PCIe lanes with 128 Gb/s bandwidth. The 32 PCIe lanes can be divided into two x16 slots by using a riser card. + +###### ➤ Ethernet + +The system should be capable to offer aggregated 48 Gb/s Ethernet bandwidth. When higher Ethernet bandwidth is required, an Ethernet card can be installed in one of the PCIe slots. + +##### ***b. Digital Processing Unit Design*** + +The digital processing unit is a system-on-a-chip (SOC) device which is a 64-bit, multi-core server class processor. This SoC includes an integrated Platform Controller Hub (PCH), integrated high-speed I/O, Integrated Memory Controllers (IMC), and four integrated 10 Gigabit Ethernet ports. The SOC supports 512-bit wide vector processing instruction set. It also supports hardware virtualization to enable dynamic provisioning of services as communication service providers extend network function virtualization (NFV). **Error! Reference source not found.** shows the major functional blocks of the digital processing unit. + +![Figure 2-2 Digital Processing Unit Block Diagram. The diagram shows a central box labeled 'Digital Processing Unit'. Inside this box, there are five sub-components: 'Ethernet Ports' at the top, 'PCH' on the left, 'Cores' in the center, 'IMC' on the right, and 'Caches' at the bottom.](8ae1533a68bdd4424daa4802fa482a00_img.jpg) + +``` + +graph TD + subgraph DigitalProcessingUnit [Digital Processing Unit] + EthernetPorts[Ethernet Ports] + PCH[PCH] + Cores[Cores] + IMC[IMC] + Caches[Caches] + end + +``` + +Figure 2-2 Digital Processing Unit Block Diagram. The diagram shows a central box labeled 'Digital Processing Unit'. Inside this box, there are five sub-components: 'Ethernet Ports' at the top, 'PCH' on the left, 'Cores' in the center, 'IMC' on the right, and 'Caches' at the bottom. + +Figure 2-2 Digital Processing Unit Block Diagram + +#### 2.2.2.2 Hardware Accelerator + +Hardware accelerators may be used in O-DU<sub>6</sub> to offload computationally intensive functions and to optimize the performance under varying traffic and loading conditions. The acceleration functional requirements and implementation are system designer's choice; however, the O-DU<sub>6</sub> shall meet the minimum system performance requirements under various loading and deployment conditions. In most cases, an FPGA or ASIC based PCIe card can be used to optimize the system performance. Examples for O-DU<sub>6</sub> could be security, network interface controller, and general packet acceleration. Specific accelerator designs are not called out in this specification. + +### 2.2.3 Synchronization and Timing + +#### 2.2.3.1 Synchronization and Timing Design 1 + +The timing synchronization of O-DU<sub>6</sub> is achieved by utilizing IEEE1588 via Ethernet ports. The Network Interface Controllers (NIC) that are used for fronthaul and backhaul support the IEEE1588 protocol. + +##### *a. Hardware Requirements* + +The O-DU<sub>6</sub> shall support at least one of following timing synchronization methods: + +1. Ethernet based IEEE1588 +2. GNSS based timing synchronization. + +##### *b. Hardware Design* + +Depending on the timing distribution topologies used, the O-DU<sub>6</sub> system clock is able to synchronize with the Grand Master Clock (GMC) using IEEE1588 via either the fronthaul NIC or backhaul NIC, or synchronizing timing using Global Navigation Satellite System (GNSS). In the case of IEEE1588, the Physical Hardware Clock (PHC) within the NIC is synchronized with the GMC first, then the O-DU<sub>6</sub> system clock is synchronized with the PHC. The O-DU<sub>6</sub> is also capable to provide clock to the O-RU<sub>6</sub> via fronthaul if needed. When GNSS is available to O-DU<sub>6</sub>, it is able to synchronize the system clock to Coordinated Universal Time (UTC). Figure 2-3 outlines the O-DU<sub>6</sub> timing synchronization mechanisms. + +![Figure 2-3 O-DU6 Timing Synchronization diagram. The diagram shows a central 'System Clock' block. To its left is a box labeled 'NIC' containing a 'PHC' block. A double-headed arrow connects the 'PHC' to the 'System Clock'. A blue arrow labeled 'Backhaul' points left from the 'NIC' box. To the right of the 'System Clock' is another 'NIC' box containing a 'PHC' block. A double-headed arrow connects the 'PHC' to the 'System Clock'. A blue arrow labeled 'Fronthaul' points right from the 'NIC' box. Below the 'System Clock' is a 'GNSS' block with an arrow pointing up to the 'System Clock'.](c2dd92b45cb22fca374be8d1719d4419_img.jpg) + +Figure 2-3 O-DU6 Timing Synchronization diagram. The diagram shows a central 'System Clock' block. To its left is a box labeled 'NIC' containing a 'PHC' block. A double-headed arrow connects the 'PHC' to the 'System Clock'. A blue arrow labeled 'Backhaul' points left from the 'NIC' box. To the right of the 'System Clock' is another 'NIC' box containing a 'PHC' block. A double-headed arrow connects the 'PHC' to the 'System Clock'. A blue arrow labeled 'Fronthaul' points right from the 'NIC' box. Below the 'System Clock' is a 'GNSS' block with an arrow pointing up to the 'System Clock'. + +Figure 2-3 O-DU<sub>6</sub> Timing Synchronization + +### 2.2.4 External Interface Ports + +#### a. Hardware Requirements + +Table 2-3 External Port List 2-3 shows the external ports or slots that the system provides. + +Table 2-3 External Port List + +| Port Name | Feature Description | 19 | +|--------------|--------------------------------------------|----| +| Ethernet | Octave Gigabit Ethernet LAN connectors | | +| | Dual 10GbE Base-T Ethernet connectors | | +| | Dual 10GbE SFP + Fiber Ethernet connectors | | +| USB | 2 USB 3.0 ports | | +| Serial Port | 1 COM port via RJ45 | | +| Antenna port | 1 SMA connector for GNSS | | + +##### b. Hardware Design + +The digital processing unit is a SOC device which provides all the external ports described in the hardware requirement section. The system includes 2 USB 3.0 ports, and the serial RS232 port that + +can be used for Console Redirection, e.g. Out-of-Band Management/Windows Emergency Management Services (EMS). There are a total of four 10G Ethernet ports in system, among them are two RJ45 10GbE and two 10G SFP+ ports. The system also provides a RF interface to connect GNSS antenna. + +### 2.2.5 Mechanical + +#### ➤ Mother Board + +The mechanical layout of the mother board in Figure 2-4 shows the location of major components and interface ports, and the dimension of the board. + +![Mother Board Layout diagram showing components and dimensions. The board is 8 inches wide and 10 inches high. A central SoC is 45x52.5mm. Components include LAN ports (LAN1-LAN8), USB ports, SATA ports, M.2 slots, and various connectors.](62de953afabdbfd2feecce810b32384f_img.jpg) + +The diagram illustrates the Mother Board Layout with the following components and dimensions: + +- Dimensions:** 8" width, 10" height. +- Central Component:** 45x52.5mm (SoC). +- LAN Ports:** LAN1, LAN2, LAN3, LAN4, LAN5, LAN6, LAN7, LAN8 (RJ45). +- USB Ports:** USB3.0 x2, IPMI, USB 2.0, USB Type-A. +- SATA Ports:** SATA, SATA. +- M.2 Slots:** M.2 B-key, M.2 M-key. +- Connectors:** VGA, COM, 10GbE BaseT x2, 10GbE SFP+, X557 AT2, BMC AST2500, SoC SMBus, PWR/QC, USB 2.0 Inverter, TPM Inverter, HDD PWR, Spin 2V Input, ATX 24 pin. +- Other Components:** LAN LEDs/GPIO, Front Panel, Fans (Fan1, Fan2, Fan3, Fan4, Fan5, Fan6). + +Mother Board Layout diagram showing components and dimensions. The board is 8 inches wide and 10 inches high. A central SoC is 45x52.5mm. Components include LAN ports (LAN1-LAN8), USB ports, SATA ports, M.2 slots, and various connectors. + +Figure 2-4 Mother Board Layout + +#### ➤ Chassis + +The 1U rack mount chassis contains the layout of the power supply, SSD and fans. The chassis dimension is shown in Figure 2-5. + +![Figure 2-5 Chassis Mechanical Diagram: A 3D perspective view of a rectangular chassis. The front panel features a 'Power Supply' unit on the left and an 'SSD' slot below it. The rear panel has a fan assembly labeled 'Installed Fans' and an 'Optional Fans' unit shown separately. Dimensions are indicated: 437 mm for the front width, 381 mm for the rear width, and 43 mm for the height. The chassis has mounting ears on both sides.](aca351afa0e2ac2da016b2b865c195af_img.jpg) + +Figure 2-5 Chassis Mechanical Diagram: A 3D perspective view of a rectangular chassis. The front panel features a 'Power Supply' unit on the left and an 'SSD' slot below it. The rear panel has a fan assembly labeled 'Installed Fans' and an 'Optional Fans' unit shown separately. Dimensions are indicated: 437 mm for the front width, 381 mm for the rear width, and 43 mm for the height. The chassis has mounting ears on both sides. + +**Figure 2-5 Chassis Mechanical Diagram** + +#### ➤ Cooling + +The system has 4x 40x28mm PWM fans for cooling. Up to 6 fans can be installed if needed. + +### 2.2.6 Power Unit + +In a fully loaded system with two PCIe slots populated with 75W each, the system power consumption should be less than 400W. The total system power shall be kept to less than 80% of the power supply capacity. + +#### *a. Hardware Requirements* + +The power is provided by 500W High-Efficiency power supply with PMBus 1.2. The power support input and output power rails are listed below. + +AC Input: 100-240V, 50-60Hz, 6.6A max + +DC Output: +3.3V: 12A + ++5V: 15A + ++5V standby: 3A + ++12V: 41A + +-12V: 0.2A + +#### *b. Hardware Design* + +The O-DU<sub>6</sub> chassis includes one 500W power supply unit. The power supply unit is auto-switching capable, which enables it to automatically sense and operate at a 100v to 240v input voltage. The power supply unit features are listed in Table 2-4. + +**Table 2-4 Power Supply Features** + +| Features | Parameters | +|-----------------------------|----------------------------------------------------------------| +| Output connectors | 24pin/8pin/4+4pin/HDD/I2C | +| Dimension (W x D x H) | 3.9 x 7.1 x 1.6 inch | +| Maximum Output Power | +3.3V: 12A<br>+5V: 15A<br>+12V: 41A<br>-12V: 0.2A<br>+5Vsb: 3A | +| Rated Input Voltage/Current | 100-240Vac / 6.6A max | +| Rated Input Frequency | 50-60HZ | +| Inrush current | Less than 30A | + +### 2.2.7 Thermal + +Active cooling with up to 6 fans integrated in chassis. + +### 2.2.8 Environmental and Regulations + +The O-DU<sub>6</sub> hardware system is RoHS Compliant. The power supply unit is EMC FCC/CISPR Class B compliant. Table 2-5 lists the environmental related features and parameters. + +**Table 2-5 Environmental Features** + +| Features | Description | +|---------------------------------|--------------------------------| +| Operating Temperature | -5°C to 55°C | +| Non-operating Temperature | -40°C to 70°C (-40°F to 158°F) | +| Operating Relative Humidity | 8% to 90% (non-condensing) | +| Non-operating Relative Humidity | 5% to 95% (non-condensing) | + +## 2.3 O-RU<sub>6</sub> Hardware Reference Design + +This section provides a hardware reference design for O-RU<sub>6</sub>, that is an O-RU built using the MAC/PHY split and interfaces defined in the Small Cell Forum. See references [7], [8], [9], [10] and [11]. + +### 2.3.1 O-RU<sub>6</sub> High-Level Functional Block Diagram + +Figure 2-6 shows a high-level functional block diagram depicting the major HW/SW components and internal/external interfaces for O-RU<sub>6</sub>. In this design, PHY processing in the O-RU<sub>6</sub> is handled by a specialized ASIC. O-RU<sub>6</sub> can handle fiber or metallic ethernet transport interface ports. + +![Figure 2-6 General Block Diagram for O-RU6. The diagram shows an external block 'O-CU/O-DU6' connected via bidirectional arrows to two parallel paths within a dashed box labeled 'O-RU6'. The top path consists of 'Fiber' connected to 'ASIC', which is connected to 'TCVR', then 'PA/LNA', and finally 'Ant.'. The bottom path consists of 'Ethernet' connected to 'ASIC', which is connected to 'TCVR', then 'PA/LNA', and finally 'Ant.'. All internal components within the O-RU6 box are connected sequentially with bidirectional arrows.](7c6b06d2acb53bf83c357242d4189aca_img.jpg) + +Figure 2-6 General Block Diagram for O-RU6. The diagram shows an external block 'O-CU/O-DU6' connected via bidirectional arrows to two parallel paths within a dashed box labeled 'O-RU6'. The top path consists of 'Fiber' connected to 'ASIC', which is connected to 'TCVR', then 'PA/LNA', and finally 'Ant.'. The bottom path consists of 'Ethernet' connected to 'ASIC', which is connected to 'TCVR', then 'PA/LNA', and finally 'Ant.'. All internal components within the O-RU6 box are connected sequentially with bidirectional arrows. + +Figure 2-6 General Block Diagram for O-RU<sub>6</sub> + +### 2.3.2 O-RU<sub>6</sub> Hardware Components + +The generic hardware architecture for O-RU<sub>6</sub> consists of three major parts: digital processing unit, RF processing unit and a timing unit as shown in Figure 2-7. In the next section there is a brief mapping of modules within these major blocks of O-RU<sub>6</sub>. + +![Figure 2-7 O-RU6 Architecture Diagram. The diagram shows an external block 'O-CU/O-DU6/ FHGW6' connected via an 'nFAPi' interface to an 'Ethernet' block inside a dashed box labeled 'O-RU6'. Inside the O-RU6 box, the 'Ethernet' block is connected to a 'Digital Processing Unit', which is connected to an 'RF Processing Unit'. A 'Timing Unit' block is also inside the O-RU6 box, with arrows pointing to the 'Ethernet', 'Digital Processing Unit', and 'RF Processing Unit' blocks.](cb663b50226a01a39179e5f2205a5a7d_img.jpg) + +Figure 2-7 O-RU6 Architecture Diagram. The diagram shows an external block 'O-CU/O-DU6/ FHGW6' connected via an 'nFAPi' interface to an 'Ethernet' block inside a dashed box labeled 'O-RU6'. Inside the O-RU6 box, the 'Ethernet' block is connected to a 'Digital Processing Unit', which is connected to an 'RF Processing Unit'. A 'Timing Unit' block is also inside the O-RU6 box, with arrows pointing to the 'Ethernet', 'Digital Processing Unit', and 'RF Processing Unit' blocks. + +Figure 2-7 O-RU<sub>6</sub> Architecture Diagram + +Dissimilar to option 7-2 or option 8, all L1 processing is performed by O-RU<sub>6</sub>. The processing unit handles transport and interface processing as well as all L1 modem processing. The DPU in O-RU<sub>6</sub> is composed of an NPU to terminate transport layer and a PHY ASIC for L1 processing. Figure 2-8 **Error! Reference source not found.** shows the major components used in O-RU<sub>6</sub>. + +The digital processing unit handles transport/interface processing, complete PHY ( low and high PHY functions) modem processing, Digital Down Converter (DDC), Digital Up Converter (DUC), Crest Factor Reduction (CFR) and Digital Pre-Distortion (DPD). + +The RF processing unit is comprised of the transceiver block which is responsible for functions such as Analog to Digital Converter (ADC), Digital to Analog Converter (DAC) and mixer; an amplification block which contains Power Amplifier (PA)/ Low Noise Amplifier (LNA), etc; and antenna subsystem that captures and/or transmits radio electromagnetic waves. O-RU<sub>6</sub> may use Power over Ethernet (PoE) to simplify deployment complexity. + +The Timing Unit may include Phase Locked Loop (PLL), local oscillator and timing synchronization circuitry. + +![Figure 2-8 O-RU6 Functional Module Diagram. The diagram shows the internal architecture of an O-RU6. It is divided into three main sections: a Digital Processing Unit (DPU), an RF Processing Unit, and a Timing Unit. The DPU contains an nFAPI Handler, Hi +Lo PHY, DDC/DUC, and CFR/DPD blocks. The RF Processing Unit contains a Transceiver ADC/DAC and MIXER, PA/LNA, and ANT blocks. An Ethernet Interface connects the DPU to the external 'To/From O-DU6'. The Timing Unit provides synchronization signals to the Ethernet Interface, the DPU, and the RF Processing Unit.](557182a42e2ab26ed00c8d6ea5ae6792_img.jpg) + +``` + +graph LR + subgraph O-RU6 + subgraph DPU [Digital Processing Unit] + nFAPI[nFAPI Handler] <--> HiLo[Hi +Lo PHY] + HiLo <--> DDC[DDC/DUC] + DDC <--> CFR[CFR/DPD] + end + subgraph RFU [RF Processing Unit] + Transceiver[Transceiver ADC/DAC and MIXER] <--> PALNA[PA/LNA] + PALNA <--> ANT[ANT] + end + TU[Timing Unit] + EI[Ethernet Interface] + + EI <--> nFAPI + EI <--> TU + TU <--> DDC + TU <--> Transceiver + end + +``` + +Figure 2-8 O-RU6 Functional Module Diagram. The diagram shows the internal architecture of an O-RU6. It is divided into three main sections: a Digital Processing Unit (DPU), an RF Processing Unit, and a Timing Unit. The DPU contains an nFAPI Handler, Hi +Lo PHY, DDC/DUC, and CFR/DPD blocks. The RF Processing Unit contains a Transceiver ADC/DAC and MIXER, PA/LNA, and ANT blocks. An Ethernet Interface connects the DPU to the external 'To/From O-DU6'. The Timing Unit provides synchronization signals to the Ethernet Interface, the DPU, and the RF Processing Unit. + +Figure 2-8 O-RU<sub>6</sub> Functional Module Diagram + +### 2.3.3 O-RU<sub>6</sub> Functional Module Description + +![Figure 2-9 Sub-6 GHz Indoor Pico O-RU6 Functional Modules (Split Option 6). The diagram shows a functional architecture within a large box. On the left, 'nFAPI interfaces over Fiber/Ethernet' connect to a 'Network Processing Unit'. The 'Network Processing Unit' connects to a 'PHY Layer ASIC' via 'FAPI over PCIe'. The 'PHY Layer ASIC' connects to an 'RF Front End', which has two antenna symbols on the right. Below the main units is a 'Power Management' block. Lines connect the 'Network Processing Unit', 'PHY Layer ASIC', and 'RF Front End' to the 'Power Management' block.](cb627a044994cc58cd56604ea8eec02d_img.jpg) + +Figure 2-9 Sub-6 GHz Indoor Pico O-RU6 Functional Modules (Split Option 6). The diagram shows a functional architecture within a large box. On the left, 'nFAPI interfaces over Fiber/Ethernet' connect to a 'Network Processing Unit'. The 'Network Processing Unit' connects to a 'PHY Layer ASIC' via 'FAPI over PCIe'. The 'PHY Layer ASIC' connects to an 'RF Front End', which has two antenna symbols on the right. Below the main units is a 'Power Management' block. Lines connect the 'Network Processing Unit', 'PHY Layer ASIC', and 'RF Front End' to the 'Power Management' block. + +Figure 2-9 Sub-6 GHz Indoor Pico O-RU<sub>6</sub> Functional Modules (Split Option 6) + +Mapping the generic hardware architecture to this hardware reference design, the DPU is split to an NPU and PHY ASIC, with an internal interface using FAPI over a PCIe interface. + +Functional blocks shown in Figure 2-9 are discussed below. + +#### 2.3.3.1 Network Processing Unit (NPU) + +The Network Processing Unit (NPU) for O-RU<sub>6</sub> terminates the external nFAPI interfaces and provides the internal FAPI interface to the PHY ASIC. + +##### 2.3.3.1.1 Networking I/O + +- Minimum I/O is a single 10GbE port that can be used with electrical or optical I/O +- Optionally, support can be added for + - OAM / maintenance port (1GbE) connecting over RGMII to the NPU + - An additional 10GbE port for chaining or failover connectivity. By implication, the NPU needs to support efficient local switch/routing functionality + +Networking side connectivity is shown as below: + +![Figure 2-10 O-RU6 Networking I/O diagram showing NPU connectivity options.](3caaa9ddad1b4181d9068f1d16a87128_img.jpg) + +The diagram illustrates the networking I/O architecture for an NPU. A large grey box labeled 'NPU' contains three vertical stacks of components: 'Ethernet 10G MAC', 'Ethernet 10G MAC', and 'Ethernet 1G MAC'. To the left of these stacks are three sets of external components: + + +- Top: '1/2.5/10 GbE' connected to a 'PHY' block, which is connected to a 'Re-Timer' block, which in turn connects to the 'Ethernet 10G MAC' stack. A dashed arrow from the 'Re-Timer' points to the text 'Optional 1588 + SyncE timing I/O'. +- Middle: '1/2.5/10 GbE (Optional)' connected to a dashed 'PHY' block, which connects to a dashed 'Re-Timer' block, which connects to the 'Ethernet 10G MAC' stack. +- Bottom: '1 GbE (Optional)' connected to a dashed 'RJ45' block, which connects via a dashed 'RGMII' line to the 'Ethernet 1G MAC' stack. + +Figure 2-10 O-RU6 Networking I/O diagram showing NPU connectivity options. + +Figure 2-10 O-RU<sub>6</sub> Networking I/O + +Example SFP connectivity is shown below: + +![Figure 2-11 O-RU6 SFP Connectivity diagram showing the signal path from NPU to SFP+ module.](390e6776641e490042a36d6ca17d5b4a_img.jpg) + +The diagram shows the SFP connectivity path. On the left, an 'NPU' block contains a 'Mux' and 'Pre-Emphasis' block, and a 'De-Mux' and 'Equal+CDR' block. A signal path goes from 'Pre-Emphasis' to an 'Ethernet Optical PHY' block. This PHY is connected to an 'SFP+ Connector' via an 'XFI Channel' (represented by an oval) and an 'SFI Channel' (represented by two parallel lines). The 'SFP+ Connector' is part of an 'SFP+ Module' which contains an 'LD Driver' (with a 'Laser' and 'PD/TIA' sub-components) and a 'Limiter'. The module has two outputs: 'TP2' and 'TP3'. + +Figure 2-11 O-RU6 SFP Connectivity diagram showing the signal path from NPU to SFP+ module. + +Figure 2-11 O-RU<sub>6</sub> SFP Connectivity + +##### 2.3.3.1.2 Low-speed connectivity and boot + +This picture shows typical low-speed I/O associated with the NPU + +![Figure 2-12 O-RU6 Low-speed NPU Connectivity diagram. The diagram shows a central NPU block with various interfaces on its left side. On the far left, there are labels for 'Temp', 'Fan', 'SFP', 'RTC', and '...'. Below these are boxes for 'I2C', 'UART Conn.', 'CPLD', 'JTAG conn.', 'eMMC', and 'NOR Flash'. On the right side of the NPU block, there are boxes for 'I2C', 'UART', 'RCW/ Rst', 'JTAG', 'eSDHC', and 'QSPI'. Double-headed arrows connect the external boxes to the corresponding NPU interfaces.](592e391868768a094012c09fd995f741_img.jpg) + +Figure 2-12 O-RU6 Low-speed NPU Connectivity diagram. The diagram shows a central NPU block with various interfaces on its left side. On the far left, there are labels for 'Temp', 'Fan', 'SFP', 'RTC', and '...'. Below these are boxes for 'I2C', 'UART Conn.', 'CPLD', 'JTAG conn.', 'eMMC', and 'NOR Flash'. On the right side of the NPU block, there are boxes for 'I2C', 'UART', 'RCW/ Rst', 'JTAG', 'eSDHC', and 'QSPI'. Double-headed arrows connect the external boxes to the corresponding NPU interfaces. + +Figure 2-12 O-RU<sub>6</sub> Low-speed NPU Connectivity + +In addition, the device can optionally be configured for secure boot. + +##### 2.3.3.1.3 DDR + +- Assuming a telecommunications-tuned Linux image and virtualization through containerization, accommodate for 512Mbyte for hosting the Linux OS from DDR +- Buffering needs to be provided for FAPI messages, but this is expected to be limited to few Mbyte (marginal) as well as debug / OAM logging functionality +- In aggregate, assume ~1Gbyte aggregate DDR dimensioning +- For bandwidth estimation, assume ~5Gbps of Ethernet throughput with 2 paths to/from the DDR interface + - Receive / Transmit from / to Ethernet MAC to DDR + - Receive / Transmit from / to DDR to PCIe + +Aggregate is ~10Gbps or 15Gbps with margin. Given a maximum utilization of the DDR interface of 50%, we require 30Gbps of raw memory throughput. A 1.6GTPS DDR memory controller with 32bits memory bus width provides 50Gbps throughput and is thus enough to support this use-case as well as additional bandwidth requirements for switch/routing functions to optional Ethernet ports. + +- ECC is assumed to be a required for a telecom-grade application. + +![Figure 2-13 O-RU6 DDR architecture diagram. It shows an external DDR block connected to an internal DDR block within an NPU block. The connection is labeled '32b+ECC'.](5f84545e67bb6c7a4851155ad2beffa6_img.jpg) + +``` + +graph TD + ExternalDDR[DDR] <--> |32b+ECC| InternalDDR[DDR] + subgraph NPU [NPU] + InternalDDR + end + +``` + +Figure 2-13 O-RU6 DDR architecture diagram. It shows an external DDR block connected to an internal DDR block within an NPU block. The connection is labeled '32b+ECC'. + +Figure 2-13 O-RU<sub>6</sub> DDR + +##### 2.3.3.1.4 Processor subsystem + +- The NPU needs to incorporate a processor subsystem that is capable of processing networked FAPI messages and convert them to PCI messages. Dimensioning of the CPU is outside of the scope. + +##### 2.3.3.1.5 Modem I/O + +- For bandwidth estimation, assume ~5Gbps of throughput. Adding 20% of signaling overhead, this becomes ~6Gbps. +- Assuming PCIe gen3 operation, 2 lanes of PCIe @8Gbps provide sufficient overhead above this bandwidth. + +![Figure 2-14 O-RU6 Modem I/O architecture diagram. It shows an NPU block containing a PCIe block, which is connected to a Modem block containing a PCIe block. The connection is labeled 'Gen3 x2'.](87cd62e9b693b0928b9a8820de214c51_img.jpg) + +``` + +graph TD + subgraph NPU [NPU] + NPUPCIe[PCIe] + end + subgraph Modem [Modem] + ModemPCIe[PCIe] + end + NPUPCIe <--> |Gen3 x2| ModemPCIe + +``` + +Figure 2-14 O-RU6 Modem I/O architecture diagram. It shows an NPU block containing a PCIe block, which is connected to a Modem block containing a PCIe block. The connection is labeled 'Gen3 x2'. + +Figure 2-14 O-RU<sub>6</sub> Modem I/O + +##### 2.3.3.1.6 Security + +- The NPU needs to support high-speed ciphering and protocol processing capabilities to support a (IPSec) secured backhaul interface. This can be achieved through integrated networking acceleration or an external accelerator as shown below. + +![Diagram showing NPU connected to an optional Cipher Accelerator via PCIe interfaces, with a Gen3 x2 connection label.](2134194e3647ddc25ccdf3d168d151da_img.jpg) + +``` + +graph TD + NPU[NPU] + subgraph Opt_Cipher_Accelerator [opt. Cipher Accelerator] + CA_PCIe[PCIe] + end + NPU_PCIe[PCIe] + NPU_PCIe <-->|Gen3 x2| CA_PCIe + +``` + +Diagram showing NPU connected to an optional Cipher Accelerator via PCIe interfaces, with a Gen3 x2 connection label. + +Figure 2-15 O-RU<sub>6</sub> NPU Security + +#### 2.3.3.2 PHY Layer ASIC + +The PHY Layer ASIC is an application specific integrated circuit that provides a highly integrated and power-efficient solution implementing the complete 5G-NR PHY layer. It includes variants for both sub-6 GHz (FR1) and mmWave (FR2) frequency ranges. These ASICs can be used to implement self-contained, all-in-one small cells, as well as Option 6 radio units (RU) for disaggregated RAN systems. In either case, the ASIC connects to a co-located network processing unit (NPU) via a PCIe interface. In the case of a self-contained small cell, the NPU hosts the full L2/L3 protocol stack (i.e., RLC, MAC, PDCP) which connects to the PHY via the 5G FAPI logical interface over PCIe. In the case of an Option 6 RU, the NPU terminates the 5G nFAPi fronthaul connection between the CU/DU and the RU and connects to the PHY via the aforementioned 5G FAPI logical interface (over PCIe.) + +![Figure 2-16 O-RU6 PHY ASIC block diagram. The diagram shows three main vertical sections. The left section is a light blue box containing four stacked blue boxes labeled 'PCIe', 'USB', 'HSUART', and 'GPIO', with 'I/O' written below them. The middle section contains three stacked blue boxes labeled 'CPU 1', 'Power Mgmt', and 'CPU 2'. The right section is a single large blue box labeled '5G Modem Subsystem'. Below the right section is the label 'PHY ASIC'.](4bce9508cd94ec490d1a520a585860ad_img.jpg) + +Figure 2-16 O-RU6 PHY ASIC block diagram. The diagram shows three main vertical sections. The left section is a light blue box containing four stacked blue boxes labeled 'PCIe', 'USB', 'HSUART', and 'GPIO', with 'I/O' written below them. The middle section contains three stacked blue boxes labeled 'CPU 1', 'Power Mgmt', and 'CPU 2'. The right section is a single large blue box labeled '5G Modem Subsystem'. Below the right section is the label 'PHY ASIC'. + +**Figure 2-16 O-RU<sub>6</sub> PHY ASIC block diagram** + +Figure above provides a high-level diagram of the functional blocks that make up the PHY ASIC. External interfaces, including PCIe, USB, HS-UART, and GPIOs, are shown on the left-hand side. There are two embedded general-purpose CPUs available as well as a power management subsystem. The most important block is the 5G-NR Modem Subsystem. + +![Block diagram of the 5G Modem Subsystem. The diagram shows a central 'Network-on-Chip' block connected to several functional blocks. On the left, there is a large block for 'LDPC & Polar Encoder/Decoder'. To its right are 'Precoder' and 'Demapper' blocks. Further right is a large block for 'IFFT/FFT Engines'. On the far right, a light blue shaded area contains 'Tx' and 'Rx' blocks, with 'DFE' (Digital Front-End) below them. Below the Network-on-Chip, there are two groups of blocks: 'CPUs' and 'DSPs', each with multiple smaller blocks and dashed lines indicating interconnections. The entire assembly is labeled '5G Modem Subsystem'.](cec5898472d1b411c005dcd7105103b4_img.jpg) + +Block diagram of the 5G Modem Subsystem. The diagram shows a central 'Network-on-Chip' block connected to several functional blocks. On the left, there is a large block for 'LDPC & Polar Encoder/Decoder'. To its right are 'Precoder' and 'Demapper' blocks. Further right is a large block for 'IFFT/FFT Engines'. On the far right, a light blue shaded area contains 'Tx' and 'Rx' blocks, with 'DFE' (Digital Front-End) below them. Below the Network-on-Chip, there are two groups of blocks: 'CPUs' and 'DSPs', each with multiple smaller blocks and dashed lines indicating interconnections. The entire assembly is labeled '5G Modem Subsystem'. + +**Figure 2-17 O-RU<sub>6</sub> 5G Modem Subsystem** + +Figure above depicts a block diagram of the Modem Subsystem within the ASIC, which is predominantly software defined, leveraging a number of embedded DSPs and CPUs which together implement the transmit and receive functionalities of the 5G modem. The modem also includes hardware accelerators for computationally intensive tasks such as FFTs, demapping, and LDPC encoding/decoding. The various functional blocks are interconnected via a network-on-chip (NOC). The modem subsystem also includes a digital front-end responsible for signal conditioning in both the transmit (downlink) and receive (uplink) directions. + +#### 2.3.3.3 RF Front End + +The Radio Frequency Front End (RFFE) is made up of all components between the modem and antennas. These include RF transceivers, RF switches, filters, duplexers, power amplifiers, and low-noise amplifiers. + +#### 2.3.3.4 Power Management + +The Power Management functional module controls the flow of electrical power to other parts of the O-RU<sub>6</sub>. + +### 2.3.4 Synchronization and Timing + +#### 2.3.4.1 Hardware Requirements + +O-RU timing synchronization sources include: + +- Ethernet based IEEE1588 +- Ethernet based Synchronous Ethernet +- Optional Global Navigation Satellite System (GNSS) based timing synchronization + +Timing functionality is shown in the diagram below: + +![Figure 2-18 Timing Modules diagram showing the flow of timing information between O-CU/O-DU/FHGW6, Ethernet Interface, Digital Processing Unit, RF Processing Unit, and Timing Unit.](139fc987a389075596746192ed692d94_img.jpg) + +``` + +graph LR + OCU["O-CU/ +O-DU6/ +FHGW6"] <--> EI["Ethernet +Interface"] + EI <--> DPU["Digital +Processing +Unit"] + DPU <--> RPU["RF Processing +Unit"] + EI -- "Recovered +Clock" --> TU["Timing +Unit"] + EI -- "1588 & +PPS" --> TU + TU -- "Time of Day" --> DPU + TU -- "Frame/Slot +Timing" --> DPU + TU -- "ADC/DAC, RF +Reference Clock" --> RPU + GNSS["10MHz, PPS, +NMEA (GPS) +(optional)"] -.-> TU + +``` + +The diagram illustrates the timing modules and their interconnections. The O-CU/O-DU<sub>6</sub>/FHGW<sub>6</sub> block is connected to the Ethernet Interface block. The Ethernet Interface block is connected to the Digital Processing Unit (DPU) and the Timing Unit (TU). The DPU is connected to the RF Processing Unit (RPU). The Ethernet Interface block provides a Recovered Clock and 1588 & PPS signals to the Timing Unit. The Timing Unit provides Time of Day and Frame/Slot Timing signals to the DPU. The Timing Unit provides an ADC/DAC, RF Reference Clock signal to the RPU. The Timing Unit also receives optional 10MHz, PPS, and NMEA (GPS) signals. + +Figure 2-18 Timing Modules diagram showing the flow of timing information between O-CU/O-DU/FHGW6, Ethernet Interface, Digital Processing Unit, RF Processing Unit, and Timing Unit. + +Figure 2-18 Timing Modules + +IEEE1588 time stamping can be done at the Ethernet PHY level (model 1 below) or at the Ethernet MAC/Network Processing Unit (NPU) level (model 2 below). Model 1 is expected to provide incremental precision. + +#### 2.3.4.2 Synchronization and Timing Design 1 + +Timing synchronization on Ethernet PHY based 1588 and Synchronous Ethernet received clock extraction support. + +![Figure 2-19 Ethernet Synchronization I. This block diagram illustrates the synchronization architecture. At the top, three main blocks are connected horizontally: 'O-CU/ O-DU6/ FHGW6' on the left, 'Ethernet PHY' in the middle, 'Network Processing Unit' in the center, and 'PHY Layer ASIC' on the right. Below these, a 'GPS Module' and a 'Clock Synth' are shown. The 'GPS Module' provides a 'PPS' signal to a 'mux' block and a '10MHz' signal to the 'Clock Synth'. The 'mux' block also receives a 'PPS' signal from the 'Ethernet PHY' and outputs to the 'Clock Synth'. The 'Clock Synth' outputs 'tx_clk', '3GPP_clk', and 'rec_clk' signals to the 'Ethernet PHY' and 'Network Processing Unit'. The 'Network Processing Unit' outputs a 'servo' signal to the 'Clock Synth' and 'PPS' and '3GPP clock' signals to the 'PHY Layer ASIC'. The 'PHY Layer ASIC' also outputs 'PPS' and '3GPP clock' signals. Dashed lines indicate optional connections, such as the 'nmea' signal from the 'GPS Module' to the 'Network Processing Unit'.](545cf03a7a687c0853f293b7d7b7ad46_img.jpg) + +Figure 2-19 Ethernet Synchronization I. This block diagram illustrates the synchronization architecture. At the top, three main blocks are connected horizontally: 'O-CU/ O-DU6/ FHGW6' on the left, 'Ethernet PHY' in the middle, 'Network Processing Unit' in the center, and 'PHY Layer ASIC' on the right. Below these, a 'GPS Module' and a 'Clock Synth' are shown. The 'GPS Module' provides a 'PPS' signal to a 'mux' block and a '10MHz' signal to the 'Clock Synth'. The 'mux' block also receives a 'PPS' signal from the 'Ethernet PHY' and outputs to the 'Clock Synth'. The 'Clock Synth' outputs 'tx\_clk', '3GPP\_clk', and 'rec\_clk' signals to the 'Ethernet PHY' and 'Network Processing Unit'. The 'Network Processing Unit' outputs a 'servo' signal to the 'Clock Synth' and 'PPS' and '3GPP clock' signals to the 'PHY Layer ASIC'. The 'PHY Layer ASIC' also outputs 'PPS' and '3GPP clock' signals. Dashed lines indicate optional connections, such as the 'nmea' signal from the 'GPS Module' to the 'Network Processing Unit'. + +Figure 2-19 Ethernet Synchronization I + +##### Notes: + +- Either (depending on mux / input control) GPS 10MHz or Synchronous Ethernet recovered output clock (ref\_clk) are input to a clock synthesizer (fractional PLL) to generate the 38.4, 122.88 MHz (or similar) MHz reference clock (Frequency Synchronization) +- The PPS pulse from the GPS provides a mechanism to manage local 122.88 (or similar) 3GPP clock through use of a Software PLL (servo) in absence of GPS/Synchronous Ethernet extracted reference frequency +- On top of the GPS PPS pulse, the GPS UART output provides time synchronization to a universal clock through NMEA messages +- The mux in the system allows the Network Processing Unit to control which input is used as PPS source (GPS module or Ethernet PHY) +- All dashed lines are indicating optionality – GPS support is optional for this system +- IEEE1588 provides both time synchronization and frequency synchronization of a local 122.88MHz clock through Ethernet time stamping such as supported in Layerscape devices. Synchronous Ethernet can be used in conjunction with this for local 3GPP clock generation. + +#### 2.3.4.3 Synchronization and Timing Design 2 + +Timing synchronization on Network Processing Unit based 1588 and Synchronous Ethernet received clock extraction support. + +Image: O-RAN Alliance Logo + +O-RAN.WG7.IPC-HRD-Opt6.0-v02.00 + +![Figure 2-20 Ethernet Synchronization II](a664db818cf6b83e6c9b666480475dc5_img.jpg) + +**Figure 2-20 Ethernet Synchronization II** + +Detailed description of the diagram: + The diagram shows the block diagram for Ethernet Synchronization II. + It contains the following blocks: + - O-CU/O-DU\_6/FHGW\_6 connected bi-directionally to Ethernet PHY. + - Ethernet PHY connected bi-directionally to Network Processing Unit. + - Network Processing Unit connected bi-directionally to PHY Layer ASIC. + - GPS Module providing PPS and 10MHz signals. + - Clock Synth (Clock Synthesizer) receiving signals and providing clocks (3GPP clock, servo, etc.) to the Network Processing Unit and PHY Layer ASIC. + - A multiplexer (mux) selecting between PPS from Ethernet PHY and PPS from GPS Module. + - Various clock and control lines (PPS, rec\_clk, 3GPP clock, servo, tx\_clk, 10MHz, nmea) connecting the blocks. + - Dashed lines indicate optionality (GPS support is optional). + +Figure 2-20 Ethernet Synchronization II + +Notes: + +- Either (depending on mux / input control) GPS 10MHz or Synchronous Ethernet recovered output clock (ref\_clk) are input to a clock synthesizer (fractional PLL) to generate the 38.4, 122.88 MHz (or similar) MHz reference clock (Frequency Synchronization) +- The PPS pulse from the GPS provides a mechanism to manage local 122.88 (or similar) 3GPP clock through use of a Software PLL (servo) in absence of GPS/Synchronous Ethernet extracted reference frequency +- On top of the GPS PPS pulse, the GPS UART output provides time synchronization to a universal clock through NMEA messages +- All dashed lines are indicating optionality – GPS support is optional for this system +- IEEE1588 provides both time synchronization and frequency synchronization of a local 122.88MHz clock through Ethernet time stamping such as supported in Layerscape devices. Synchronous Ethernet can be used in conjunction with this for local 3GPP clock generation. + +### 2.3.5 External Interface Ports + +The O-RU<sub>6</sub> must have at least one RJ45 10 gigabit per second (Gbps) Ethernet interface or at least one 10 Gbps optical interface. In some cases, depending on the fronthaul throughput associated with smaller air interface bandwidths, a 1 to 2.5 Gbps Ethernet or optical interface may be sufficient, depending on system operator requirements. SCF 5G nFAPI should be supported. At full load, the power consumption must not exceed the limit allowed by IEEE802.3at/PoE+, which is 25.5W. + +### 2.3.6 Power Unit + +O-RU<sub>6</sub> can use power over Ethernet (PoE) to simplify deployment complexity. + +--- + +| | | +|--------------------------------------------------------------------------------------------------------------------------------|----| +| Copyright 2021 O-RAN ALLIANCE e.V.<br>Your use is subject to the terms of the O-RAN Adopter License Agreement in the Annex ZZZ | 30 | +|--------------------------------------------------------------------------------------------------------------------------------|----| + +### 2.3.7 Environmental and Regulations + +O-RU<sub>6</sub> IPC design is for indoor environments (nominal ambient temperature, humidity, altitude). Suppliers must comply with any local regulatory requirements. + +## 2.4 Integrated gNB-DU Reference Design Solution + +This Section includes a reference design for an all-in-one, integrated gNB-DU solution. This section provides an example white box design for integrated indoor picocells, using FAPI as the internal interface between PHY and MAC. Typically, the MAC will run on an NPU while the PHY resides in a PHY Layer ASIC, connected via a PCIe interface. + +![Figure 2-21 Sub-6 GHz Indoor Pico Integrated O-DU&O-RU Functional Modules. The diagram shows a block diagram of functional modules for an integrated O-DU&O-RU. A large box contains four main components: Network Processing Unit (NPU), PHY Layer ASIC, GPS Receiver, and RF Front End. The NPU is connected to the PHY Layer ASIC via a 'FAPI on PCIe' interface. The PHY Layer ASIC is connected to the GPS Receiver and the RF Front End. A Power Management block is connected to the NPU, PHY Layer ASIC, and RF Front End. External connections include 'F1' on the left and two antenna symbols on the right connected to the GPS Receiver and RF Front End.](7874a37ff237673b53664e8c1175e334_img.jpg) + +Figure 2-21 Sub-6 GHz Indoor Pico Integrated O-DU&O-RU Functional Modules. The diagram shows a block diagram of functional modules for an integrated O-DU&O-RU. A large box contains four main components: Network Processing Unit (NPU), PHY Layer ASIC, GPS Receiver, and RF Front End. The NPU is connected to the PHY Layer ASIC via a 'FAPI on PCIe' interface. The PHY Layer ASIC is connected to the GPS Receiver and the RF Front End. A Power Management block is connected to the NPU, PHY Layer ASIC, and RF Front End. External connections include 'F1' on the left and two antenna symbols on the right connected to the GPS Receiver and RF Front End. + +**Figure 2-21 Sub-6 GHz Indoor Pico Integrated O-DU&O-RU Functional Modules** + +Functional modules shown in Figure 2-21 for the integrated case are essentially the same as those in the O-RU<sub>6</sub> split option. The main difference is in the NPU, which now terminates the O-CU/gNB-DU interface. + +The integrated gNB-DU may also include a GPS receiver to locally provide location and precise timing (as opposed to depending on the O-CU for those functions.) + +The integrated Option 6 design does not require an accelerator. + +As in the split design, the DPU is a combination of NPU and PHY ASIC (same parts whether split or integrated.) + +### 2.4.1 Power Unit + +If PoE is used, At full load, the power consumption must not exceed the limit allowed by IEEE802.3at/PoE+, which is 25.5W. + +#### 2.4.1.1 Power Management + +The Power Management functional module controls the flow of electrical power to other parts of the integrated O-DU/O-RU. + +### 2.4.2 Synchronization and Timing + +Local 1588v2 or GPS Slave interfaces for acquiring timing and synchronization can be included according to operator use case and deployment environment. + +### 2.4.3 External Interface Ports + +The integrated O-DU/O-RU must have at least one RJ45 10 gigabit per second (Gbps) Ethernet interface or at least one 10 Gbps optical interface. In some cases, depending on the fronthaul throughput associated with smaller air interface bandwidths, a 1 or 2.5 Gbps Ethernet or optical interface may be sufficient, depending on system operator requirements. SCF 5G nFAPI should be supported. + +### 2.4.4 Power Unit + +Integrated O-DU/O-RU can use power over Ethernet (PoE) to simplify deployment complexity. At full load, the power consumption must not exceed the limit allowed by IEEE802.3at/PoE+, which is 25.5W. + +### 2.4.5 Environmental and Regulations + +Integrated O-DU/O-RU IPC design is for indoor environments (nominal ambient temperature, humidity, altitude). Suppliers must comply with any local regulatory requirements. + +## 2.5 FHGW Hardware Reference Design + +A FHGW is not required for option 6 hardware reference design. + +# Annex 1: Example Hardware Bill of Materials + +This annex shows example components used to build the reference design described above for split and integrated option 6 designs (note that the same components are used for either scenario.) + +![Figure A-1: Sub-6 Split (O-RU6) and Integrated Picocell Reference Design. The diagram illustrates the hardware architecture for a sub-6 GHz split and integrated picocell. A vertical dashed line labeled 'FAPI' separates the NPU (Network Processing Unit) on the left from the FSM100xx (L1/PHY) on the right. The NPU block contains 'nFAPi and Transport Protocols (Split Case) or L3 and L2 (opt.) Processing (Integrated Case)'. It is connected to a 'Fiber/Ethernet Interface' via 'nFAPi Transport to O-DU6 (Split Case)'. The NPU is connected to the FSM100xx via a 'PCIe' interface. The FSM100xx is connected to a 'PMX50 / PMK8002 PM8005' power management IC via '38.4MHz' and '19.2MHz' signals. The PMX50 is connected to a 'VCTCXO 100ppb 38.4MHz' oscillator via 'VCTRL'. The FSM100xx is connected to a 'SiRFv5 GPS' module via 'PPS' and 'SPI' signals. The SiRFv5 GPS is connected to a 'GPS' antenna. The FSM100xx is connected to an 'RFSoc' module via 'SPI/IEEE bus', 'QLINK/CTL', and '38.4 MHz' signals. The RFSoc is connected to 'RF Passives' and a 'Sub6' antenna.](a95a42e29d7d56bada4fa7008e477284_img.jpg) + +Figure A-1: Sub-6 Split (O-RU6) and Integrated Picocell Reference Design. The diagram illustrates the hardware architecture for a sub-6 GHz split and integrated picocell. A vertical dashed line labeled 'FAPI' separates the NPU (Network Processing Unit) on the left from the FSM100xx (L1/PHY) on the right. The NPU block contains 'nFAPi and Transport Protocols (Split Case) or L3 and L2 (opt.) Processing (Integrated Case)'. It is connected to a 'Fiber/Ethernet Interface' via 'nFAPi Transport to O-DU6 (Split Case)'. The NPU is connected to the FSM100xx via a 'PCIe' interface. The FSM100xx is connected to a 'PMX50 / PMK8002 PM8005' power management IC via '38.4MHz' and '19.2MHz' signals. The PMX50 is connected to a 'VCTCXO 100ppb 38.4MHz' oscillator via 'VCTRL'. The FSM100xx is connected to a 'SiRFv5 GPS' module via 'PPS' and 'SPI' signals. The SiRFv5 GPS is connected to a 'GPS' antenna. The FSM100xx is connected to an 'RFSoc' module via 'SPI/IEEE bus', 'QLINK/CTL', and '38.4 MHz' signals. The RFSoc is connected to 'RF Passives' and a 'Sub6' antenna. + +Figure A-1: Sub-6 Split (O-RU<sub>6</sub>) and Integrated Picocell Reference Design + +Figure A-1 shows an example hardware design based on the FSM100xx ASIC for a sub-6 GHz Split (O-RU<sub>6</sub>) and Integrated picocell. In both cases, this design implements the SCF FAPI protocol over an internal PCIe interface. + +In the split Option 6 picocell case, the NPU implements the nFAPi control and data plane protocol encapsulation/decapsulation functions to provide the transport interface from the picocell to the O-DU<sub>6</sub>. See SCF 225.1.0 [11]. + +In the integrated picocell case, the NPU implements higher layer protocol functions (L3 and portions or all of L2.) + +--- + +1 + +# 2 Annex 2: + +3 + +4 This document references the following specifications from the Small Cell Forum available at +5 [https://scf.io/en/documents/all\\_documents.php](https://scf.io/en/documents/all_documents.php) + +6 + +7 SCF 222.10.03: 5G FAPI PHY API Specification + +8 SCF 082.09.05: nFAPI and FAPI Specifications + +9 SCF 223.10.02: RF and Digital Front End Control API + +10 SCF 224.10.01: 5G FAPI Network Monitor Mode API + +11 SCF 225.2.0: 5G nFAPI Specifications. + +12 + +13 + +14 + +## --- Annex ZZZ: O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN ALLIANCE and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN ALLIANCE that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN ALLIANCE or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a + +licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN ALLIANCE hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an ORAN Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN ALLIANCE. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For + +the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN ALLIANCE on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of ORAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN ALLIANCE or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN ALLIANCE, and cooperates with O-RAN ALLIANCE and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN ALLIANCE's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN ALLIANCE, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN ALLIANCE, which consent may be withheld in O-RAN ALLIANCE's sole discretion. O-RAN ALLIANCE may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +1 This Agreement constitutes the entire agreement between the parties as to its express subject matter +2 and expressly supersedes and replaces any prior or contemporaneous agreements between the +3 parties, whether written or oral, relating to the subject matter of this Agreement. + +4 Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, +5 rules and regulations with respect to its and its Affiliates' performance under this Agreement, +6 including without limitation, export control and antitrust laws. Without limiting the generality of +7 the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would +8 violate the antitrust laws. + +9 By execution hereof, no form of any partnership, joint venture or other special relationship is +10 created between Adopter, or O-RAN ALLIANCE or its Members, Contributors or Academic +11 Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any +12 commitment on behalf of Adopter, or O-RAN ALLIANCE or its Members, Contributors or +13 Academic Contributors. + +14 In the event that any provision of this Agreement conflicts with governing law or if any provision is +15 held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such +16 provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, +17 covenants and restrictions of this Agreement will remain in full force and effect. + +--- + +18 \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/027b35b317e9db756d297aa62bead3cb_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/027b35b317e9db756d297aa62bead3cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4fb919fa24b5645c88676785b20dc75a4992d2b5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/027b35b317e9db756d297aa62bead3cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c046e0b75de959c0ae271e8fbb967cf3601d0094267aef64cbdcc85a169075e +size 109280 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/029c0ccafb6b3d07f7b64e7159ee520b_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/029c0ccafb6b3d07f7b64e7159ee520b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..32af1e27b54cfb4e903aba70bc56c0e7bb75b4b5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/029c0ccafb6b3d07f7b64e7159ee520b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1101a1d68d99a9a4cb8e0b8cea479ca4528c54e8952cae1c4f94263668b5db1e +size 43052 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/044d61a1766d41f0d7179f39cbeb061d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/044d61a1766d41f0d7179f39cbeb061d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5882a137696a161585ba1071c21583767c90a7c0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/044d61a1766d41f0d7179f39cbeb061d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b63117da53f0da57b5d2963761e9634736c91a7716a12eaffc502ef50d5231f2 +size 40042 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/09cd4e4236847ca9fa10fed2f2be2bdc_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/09cd4e4236847ca9fa10fed2f2be2bdc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..43718c497897d877363ae738032deb9212a2cc3c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/09cd4e4236847ca9fa10fed2f2be2bdc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1ceec16da5c5b1cd5c2f93ff33ef9a0ea4e36b5904eecb8a9a3d1af57b17760b +size 27891 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/0de42adec678bf212796deb6f4d51747_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/0de42adec678bf212796deb6f4d51747_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b0267da8aeba045f3868105627686a910b3753d3 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/0de42adec678bf212796deb6f4d51747_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e03185185fae1d275cc1f1cdd65858c07e7f481fd1666c2eef0dda0a42624ae3 +size 4567 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/0f64203e801de7dbf38456c2fab15ec9_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/0f64203e801de7dbf38456c2fab15ec9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dbf01f5f46e5ae0e5d00a6b30def123c5230e7b5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/0f64203e801de7dbf38456c2fab15ec9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:efb1f02d9b1fa482c3211676615b77d61e07a5aca8e36debfca08d6b0013236c +size 4565 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/127787227b746204380ba8de3eb11ecc_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/127787227b746204380ba8de3eb11ecc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..60628dc0ab1dc787d82fde05aaea73fd441cd0b5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/127787227b746204380ba8de3eb11ecc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e219a75db392283ca26cd105e77e7a3839cfd369464df4d7f4d15af491d5ddd6 +size 60907 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/186b1190e1d68ae10f9732d2794db101_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/186b1190e1d68ae10f9732d2794db101_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..80b2e6b5dfaeb6047894723379533265f7b88beb --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/186b1190e1d68ae10f9732d2794db101_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6f3850df4af9571a42b8b174dd96acf16f683ca9055d4ec560da2fcb520594fa +size 4586 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1aa5e5db4f0571bb197497ee1d8d775c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1aa5e5db4f0571bb197497ee1d8d775c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bc4c22dff12a3c0b86a2c7f0429a36c5b2c0a9ab --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1aa5e5db4f0571bb197497ee1d8d775c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:24d089d1ae5780690394e427e29e59b3631965fd6a8149820126a685093e9f73 +size 20589 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1bd7299d68bfe10405a552010f94042f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1bd7299d68bfe10405a552010f94042f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2ea672073e6ccc65fcbf0a9342dcd87804e842fe --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1bd7299d68bfe10405a552010f94042f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b7c4ee8d61eb66b08442303d2d4f11f616a10762ac6e9315c1781a4e3af17452 +size 28728 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1c4406d96b3fdd345e71774056a6d456_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1c4406d96b3fdd345e71774056a6d456_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..85ffdf3d895e463c83b07071017ab9ad7d7d0633 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1c4406d96b3fdd345e71774056a6d456_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fba7f42c8144c67847db0ad5fee311e6d6a8537e7e11833308ec977084d6cd3e +size 41852 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1d81e313e553a20833e2a172352ca75c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1d81e313e553a20833e2a172352ca75c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..730f3cdf25eb3976da0a0d92e909bd8df8d69910 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/1d81e313e553a20833e2a172352ca75c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bc580ce328f252f38e1fa31f273cd21f366636f15932c26072f268e8574c6a13 +size 44942 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/20f7116cdfe2e241914ee5c706fce8b9_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/20f7116cdfe2e241914ee5c706fce8b9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9f4a594d15b33fd0d89045ed5a13f1de5b3baa85 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/20f7116cdfe2e241914ee5c706fce8b9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:47228d21a29b4896c17e8b15472db6b918eb46cd09fe5213118fc05a141a1cda +size 20402 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/2972dc5cfba5f9f777a6056341e25afc_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/2972dc5cfba5f9f777a6056341e25afc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8304f57e3bcb93491d3bb1c9f6b634058253fcd7 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/2972dc5cfba5f9f777a6056341e25afc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ac0a2876bdf78bed86fb86870030caaacaa0947f5a4b8c669bacf025a1eeec30 +size 4558 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/2f0f792fe51c6ebd4748f90cfa385b9e_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/2f0f792fe51c6ebd4748f90cfa385b9e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12202191a3e4a63f761d60d885908c9564a4d45e --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/2f0f792fe51c6ebd4748f90cfa385b9e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a1cc50dcef5fc8de503f7ec361907568c0fe516bd4036aede0db6ff79154f487 +size 66902 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/322d5df2d7bbd404d9cf2a47086c0eab_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/322d5df2d7bbd404d9cf2a47086c0eab_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..00e92adc532da48c6f541ab2a3ebd7f8217601c6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/322d5df2d7bbd404d9cf2a47086c0eab_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15a52d98de00d44d4ecfba5f8584bd10c6ae7ac8dc67669efeec514b3f850c58 +size 4559 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/34dc78544aa11598cca246ec70454935_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/34dc78544aa11598cca246ec70454935_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9d940eb553561b51221e2d8013b61986f4360f88 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/34dc78544aa11598cca246ec70454935_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e169ba1cb2ef86d8bfb15ed13e0372477c625ea48750967ed9a61eb6486c5ca8 +size 6407 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/3b9f38374684ba091e83d9cdedbc8602_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/3b9f38374684ba091e83d9cdedbc8602_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fbb0ca006f09100f067f673e956cf127fb3e533d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/3b9f38374684ba091e83d9cdedbc8602_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1de22fbed62f8ad692efaad0c5094dc53081d522b203731698212684939a3268 +size 17146 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/40a7bcfdf7ced1cfca648564df7da749_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/40a7bcfdf7ced1cfca648564df7da749_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e7ad4ac85d72f67f96d88b07ea1898b4ea2e0c51 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/40a7bcfdf7ced1cfca648564df7da749_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:10fc07d8dab3fcdd2e8741cf603f27ef031770e1852c0f31ac7ad5b59d8b9522 +size 45316 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/44870046fd66cb8ac355cf608efba739_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/44870046fd66cb8ac355cf608efba739_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8e78c713648b0f85a4b9c9bb3e95b1afe2e18914 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/44870046fd66cb8ac355cf608efba739_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d8f1e6fc6666b87499d87a55a5f40121c7a0d6d6d672efb46f3c671042052d30 +size 101163 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/456adb8be00dc3e7a703144a95e63c0e_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/456adb8be00dc3e7a703144a95e63c0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fbf783a3de6cc2045b4fe1f5fb152d77d1ea18a4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/456adb8be00dc3e7a703144a95e63c0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5717e3facaaf1ce711752c7a644cb2bb68c8ced880899e0739a10b2baeeb2501 +size 20632 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4640181bc02a1c4ceabfe8f4c2d44e34_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4640181bc02a1c4ceabfe8f4c2d44e34_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a77bac09830a1328bc6071aa23cf16c42a643fab --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4640181bc02a1c4ceabfe8f4c2d44e34_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:438034e5575641a10c88c48005cfe6c604ec18219bcbc9113effce7554f30579 +size 73337 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4b4e84bb56f4c16fdf79787e2a25a57a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4b4e84bb56f4c16fdf79787e2a25a57a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f3b7198f9ccccdec7317ff72c0fc8ed4c001e6f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4b4e84bb56f4c16fdf79787e2a25a57a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c8f536eed4205751a38d7cfc8425df27920956037caba548825ec8292511736f +size 4572 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4e4e3b9b754c1377dfbacac001247a56_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4e4e3b9b754c1377dfbacac001247a56_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8d9fe2bf08c5453929bec2ddec932956f6a923af --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4e4e3b9b754c1377dfbacac001247a56_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a21139dfc011a8718dbca0b23207e7951d0999952be7d966253a870ff76560d4 +size 13734 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4e5c4be0b9faa9d99f7b27993f51ca4f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4e5c4be0b9faa9d99f7b27993f51ca4f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..04f988985fa0e4939e5f1ccfb26b074e3a798212 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/4e5c4be0b9faa9d99f7b27993f51ca4f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f0d5b08036ea0fbef549593d2d3e793a0931409f3972b6935d2c0faf7ff82241 +size 3922 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/592c3bc69e75d00f8107318d7039bba4_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/592c3bc69e75d00f8107318d7039bba4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1513a55f5f4eed751af39a393a908151ce26f7f8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/592c3bc69e75d00f8107318d7039bba4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6b8ec3287d2d146e48d59e4b6f17654c269beb48b10b169cd01f0a233db81cc3 +size 19731 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5b04d21b726f67be23f7154274602105_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5b04d21b726f67be23f7154274602105_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2aeb707ef33ae12d1bcad97953e9f3e20b84f1f7 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5b04d21b726f67be23f7154274602105_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:565daef1c99bcbaac8789026194a55948356221fac36248f267b718e42430cb4 +size 71108 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5bab0fc869de7bd47cb622a8356254ed_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5bab0fc869de7bd47cb622a8356254ed_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cfc56096b9e6aea6239707cafe37634bf9e90cd4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5bab0fc869de7bd47cb622a8356254ed_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8bdb0dfdfb6e5ca61d019ff5d6e740aa72c4dab25f0677fc1d50b39db4ef1b36 +size 13518 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5cd221ed29927077aa6eb1df4b70341b_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5cd221ed29927077aa6eb1df4b70341b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..406c639266d7d0929e06c14a1d6d1fb006b92ae3 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5cd221ed29927077aa6eb1df4b70341b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0366a4476437167223d21132d44c69fa26bb7e729e83d755db520992bca65aae +size 67198 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5e486c02860fecf99ec2a0ff66f3fe71_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5e486c02860fecf99ec2a0ff66f3fe71_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..21c4d8322d92c29e1e4a674981729b70fd639b1c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/5e486c02860fecf99ec2a0ff66f3fe71_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f7fe9751f1a6e20fc1b6612b0317f5026b1c6f0da291cfe34aacfb97bc768898 +size 40110 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/64dfd5d51b56ba944807ed8c950afad2_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/64dfd5d51b56ba944807ed8c950afad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e4ba33aa9648d7e5d0db146e049beca656d1b975 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/64dfd5d51b56ba944807ed8c950afad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9336df2dd34004c0c4fae5a915f354e0d2d09d1a1772f054f24b4e8bf5e4f8d +size 4458 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/665babd43f0387a3fecc1d0ca2e081a8_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/665babd43f0387a3fecc1d0ca2e081a8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ee7fa10020971c6a83493a9df7b4ca2f59c81dbe --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/665babd43f0387a3fecc1d0ca2e081a8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e6b9084b9204f7cd47cd8c760c7de57c0d69d6c2ed0f05716f0607f8c51d6c27 +size 207576 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/689cd6fcf86e335627e9e60156151bbd_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/689cd6fcf86e335627e9e60156151bbd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d2319c2a8d3bed727ba7ddaeee23c2405eba8469 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/689cd6fcf86e335627e9e60156151bbd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ab77c6831afd830b3e32a483d6bcdf871c0346cb59ef5e565b18c013228d548 +size 71077 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/6c727b3eedb1f9a14e715ddcf4dfd31a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/6c727b3eedb1f9a14e715ddcf4dfd31a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..985622d5d2bf478450dddf75436364e4d2e88b19 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/6c727b3eedb1f9a14e715ddcf4dfd31a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dc571fcdc9e7f45263e69d51876a2e1b2cd0cce1037381faa0a6959c20267d0b +size 90207 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/6e4da8804902bb1ca0859f7021852736_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/6e4da8804902bb1ca0859f7021852736_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7105bb6a36ad953f8e8ec018f98e5a6659ad91c6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/6e4da8804902bb1ca0859f7021852736_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f5f0825e9759d6f8c7fdd2e323924c97017e417aaccd488a0b00b8fb294b8129 +size 4504 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/6f005941d3b40d49a03f4b9bc1d0e0bd_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/6f005941d3b40d49a03f4b9bc1d0e0bd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7eb8db2656e975bd8a4f7274347edab648d419af --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/6f005941d3b40d49a03f4b9bc1d0e0bd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c354f5e45d06c84c7a606544c59ec19008c06bedac630d4d05e6269839390eb9 +size 4613 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/7117ed3eff060bdb12c8f531495833b8_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/7117ed3eff060bdb12c8f531495833b8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d944695db5be731501fa6b0d767fb020c2865d4b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/7117ed3eff060bdb12c8f531495833b8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:90dcc62308008c3a314092dc2e732430b6f6888927b7ca689e9d86c80ff24dd4 +size 81340 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/721cab6f12e01439a2fd0894510c5ab2_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/721cab6f12e01439a2fd0894510c5ab2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bf1d6924eff536dc9e3db02f04f7cea1f45e2eba --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/721cab6f12e01439a2fd0894510c5ab2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8c6a1a494dcd7670b9c683197e82195f9619dcacd6add583410942ff90ddcafb +size 42369 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/7762c7b601a6e0ee97ec71225eb2093f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/7762c7b601a6e0ee97ec71225eb2093f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8025f6c1e87f268c313a09cba7bd4ad4097eee70 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/7762c7b601a6e0ee97ec71225eb2093f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:23f2cba08a7f059d1897798c65b7e2dc3f11829987d7262e0139128ef930ddb1 +size 6409 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/79ff17d14f050d51313216ffc5b93745_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/79ff17d14f050d51313216ffc5b93745_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b8770aab12de47ed991450eeb924eef97f8ea571 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/79ff17d14f050d51313216ffc5b93745_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:165592fb10ccf9fc9ddaae7b10f787b027aaaa786d06a733cc5d576f5afb8f3e +size 15706 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/87f58402589afd5db63f1e96c148f362_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/87f58402589afd5db63f1e96c148f362_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5105cd5c9095f1737d9f1f2c9924857974a3e4a1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/87f58402589afd5db63f1e96c148f362_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bd8ec2d0087807edf751e4b6453dd6c1b8b180855dd1b0f1346a56a0b4d5f318 +size 45049 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/8d64fd56117f88e7f6943150fc205752_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/8d64fd56117f88e7f6943150fc205752_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d4fbcbab2014599eb0d6dd5812efc8c4321f7f82 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/8d64fd56117f88e7f6943150fc205752_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ff32004dd57ac158d306c3417b69499746c80a03d2b087070d38138ceb0e6d5c +size 87876 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/8e42b7b5756105fd87d4f6393fe881d0_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/8e42b7b5756105fd87d4f6393fe881d0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..21bd897702c813b57924ae890d1910c42def0bd5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/8e42b7b5756105fd87d4f6393fe881d0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:88d15c331812fefb37d16fffe7bd240559c21c1d77a445792f9740554354e6b0 +size 29860 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/9233f2b01da1c5adbefcdfca1b581b9b_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/9233f2b01da1c5adbefcdfca1b581b9b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cf069f44f302c13e46fb9eca0fc3d1f630618787 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/9233f2b01da1c5adbefcdfca1b581b9b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c621f37a531ce7689e435a2febc63e430c34471544ad139064bda70cb9ea52d9 +size 38033 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/931f849e941982db7ffb65c79c3b7997_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/931f849e941982db7ffb65c79c3b7997_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7ad539a3236e05cbb17c887f571c29f0310773c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/931f849e941982db7ffb65c79c3b7997_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5e7482227dd3ad25bf63b9537889da35b43ca4d3ad3d4d1b5a5a318a6c480682 +size 20676 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/95284068e22805f4d70466a4874a652f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/95284068e22805f4d70466a4874a652f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d3cedfac19c735613f0310eac1ed25c94f05612f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/95284068e22805f4d70466a4874a652f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fcfe82a613c1e2cc39724c2db756120f83beb32828fefcccad77f2346b5caa81 +size 60901 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/957aab917b6f0dd92506b17f2c4f1ff4_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/957aab917b6f0dd92506b17f2c4f1ff4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f1f8eedfbde6a07e51cc776dce27253a3284a077 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/957aab917b6f0dd92506b17f2c4f1ff4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da13aa0111488cdb245cfb6f30b82ccf927014136041e3c97298712b8bc65267 +size 126488 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/959990b30bd0485ea81e876b67d37635_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/959990b30bd0485ea81e876b67d37635_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f5bfd229f46fa324f715edbf3022824ee52ea472 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/959990b30bd0485ea81e876b67d37635_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8bad5ace43cf645fdafe5ab5f4e4f04ccc28c5453eb88568d19b0fa6d9528bd +size 4540 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/99b2ccb9602e5c66655e6ba487375c27_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/99b2ccb9602e5c66655e6ba487375c27_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dbb58c0f704610770d231a6b9ea7cca5af6d7eba --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/99b2ccb9602e5c66655e6ba487375c27_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:24b55d0d5b2c3a57c0ef865628a2f1e68e596de73ff3061177f2c71b857a0524 +size 15894 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/9f0de6ba4f3ad9264276436809c17582_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/9f0de6ba4f3ad9264276436809c17582_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d51d669dfcff9577ccddabdcc7f91b946f366be8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/9f0de6ba4f3ad9264276436809c17582_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cc8d1ec43871107f547b3a55c7e6a3836ffcb46523dd98cdef10ded2c6f1b3d +size 89577 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/a1fda3ddf979227cf665adb010b960f8_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/a1fda3ddf979227cf665adb010b960f8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6aaf88d89db7c6e18ca1060155d031670b33c94c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/a1fda3ddf979227cf665adb010b960f8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e230eaa620669b486cffcb192191992886e4d6008d48c0b896e823b8afbf072a +size 63966 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/a585f78e55b1a702c0345dec436176b9_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/a585f78e55b1a702c0345dec436176b9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..823f0961dba883babe3f1b8da1563f132120ee92 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/a585f78e55b1a702c0345dec436176b9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a838f4d9e40ad7438f9499ddee808d4e7bde2b6b54128245015067697b211b2c +size 63854 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/a91200e265c630548808de0db42f4273_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/a91200e265c630548808de0db42f4273_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5fd77c174dec243d03bea5c93427ff8e0baa93d1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/a91200e265c630548808de0db42f4273_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1fc141ac1957459566f331a7883f8653603749c5fac12311abf28d5fd7339ea3 +size 4521 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ad611af56ed661fdad000030a112737b_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ad611af56ed661fdad000030a112737b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0b599b8076b19e22c0f2c3f3ca8dca9eab0d0858 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ad611af56ed661fdad000030a112737b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6c8d41fdb6112812fe6d21fba55dccae7dd4391f81bde7443963168ce9c95444 +size 4576 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/b20236b258244fa0337a0ad4cda70b70_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/b20236b258244fa0337a0ad4cda70b70_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..79e14380acb0dd4a0f35a83b7ba7769b73dc6705 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/b20236b258244fa0337a0ad4cda70b70_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:af0ba36590e7814af7056518d1aa5769515f22665dac666baa2b2299a3e14270 +size 59885 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/c577e9b3ac856919ff5e5d355882ef09_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/c577e9b3ac856919ff5e5d355882ef09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e13897a48c5f14b11f2dee6ba4d10d87931f84f7 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/c577e9b3ac856919ff5e5d355882ef09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e95feffaf5b7bd7688cb38ebfb1284b7cb5de0746b36034c27a64b768ce11a7d +size 13205 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/c682f7085f772e9bc7c42e9e1e617ce7_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/c682f7085f772e9bc7c42e9e1e617ce7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d720daf50b1508d9facd1572d818d6e6aba7d58a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/c682f7085f772e9bc7c42e9e1e617ce7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:116333f98bb6cbb3d322a950d11d6d04ab7092bcff4ecce5bbe2619f01e6be7b +size 24971 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/c7098332ecfe2319ee194a7cabe168bb_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/c7098332ecfe2319ee194a7cabe168bb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bb063d33eff350245b00fa29757fa9a487a10162 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/c7098332ecfe2319ee194a7cabe168bb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:241f4057e226ee1e04e7a1aafbd7a3f3705648217cc5e898a6a6592d740a7962 +size 4556 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/d2b50923402c459a04b7d61e8211321c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/d2b50923402c459a04b7d61e8211321c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0dad924c63183bae47b319a61dc2e8042b7a0673 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/d2b50923402c459a04b7d61e8211321c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:602855d6c6383e6788d7e2ea8ba8a562359c142d0aeb1f9fcaa62e7067f8958d +size 76133 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/d40142907976f8b5ea3646c9b0f638c9_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/d40142907976f8b5ea3646c9b0f638c9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a3dc252b9f7b26065ffad299e3fe11ba1a066d2f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/d40142907976f8b5ea3646c9b0f638c9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ccc922ecc272e5d308fd99c23d9522529ae46b858170cbd91c532275edd1dc1c +size 4546 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/db6bb73c9af7d4b1ee058439d0cb1460_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/db6bb73c9af7d4b1ee058439d0cb1460_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f4c2e37bbcc339c71aabf60f4be24b934df37935 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/db6bb73c9af7d4b1ee058439d0cb1460_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ea1c690a89422cdf72f61821c5de34596636336364c6a1f948361fd5be17c594 +size 32221 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/dc86c774296a631cbe87b2328cefa177_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/dc86c774296a631cbe87b2328cefa177_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7d8ce3102097f451dd0709fd42d2176cb80fbee5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/dc86c774296a631cbe87b2328cefa177_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d2ab2fe8a0591eb3fe27c017d6427b3e7ca71571760f77625583cf24cc5bf8b2 +size 21010 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ddb1b67b648cc0c00188b84af42b23cc_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ddb1b67b648cc0c00188b84af42b23cc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de7945b43fbc2f8487af161cd1c5f7f8b77ae4e8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ddb1b67b648cc0c00188b84af42b23cc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5e39cbbfab7fb518953ab1167bf0a1cd2da5ed1c8d21067f9aaeca822fe4fb50 +size 36871 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/e02b7368461b4e84ef53b64683feb2cb_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/e02b7368461b4e84ef53b64683feb2cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..92c361599c3baabc5cccb46edc13406951e9c589 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/e02b7368461b4e84ef53b64683feb2cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b795e9776e5908012513b3eb5f9257fc19840f9c75775b3647b687dcac220369 +size 34520 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/e755e3e2c4afe67194b013a72c33c094_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/e755e3e2c4afe67194b013a72c33c094_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..655da3457ea1bce51f6853306733f49ba5a14c50 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/e755e3e2c4afe67194b013a72c33c094_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b14cc4e556f66078773a163b98ea9ee81c4d903ff421a1d411c223832e4b47a7 +size 58346 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/e7d084b12ece9fc7f784e3f755256d67_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/e7d084b12ece9fc7f784e3f755256d67_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2b474f45ee30ffb35b68595087e4e0be1d450990 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/e7d084b12ece9fc7f784e3f755256d67_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1662739d46d4c2bd8ae23573494aee459e45b543ba40441bb98dda54e44c68f7 +size 51703 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/eda08cbd318993c87bf3f3dc326243e7_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/eda08cbd318993c87bf3f3dc326243e7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..71f990b198c72395dcd2d7abb5bc5f7408a3f668 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/eda08cbd318993c87bf3f3dc326243e7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fe661ed300afddda660accfaca4d43922a2a42b14370e54365154c1892b815a1 +size 67638 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ee465fd7e617a0833acdd69e83e266ff_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ee465fd7e617a0833acdd69e83e266ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..59c58c52f6aad73774db248ae764a598616fcaed --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ee465fd7e617a0833acdd69e83e266ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c3bfe6f3e7ba47fa9fcdfe93fa0333821738659c6de8ed4c975ad12fc33560de +size 48263 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f0f7785d9296fdba3169212350218846_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f0f7785d9296fdba3169212350218846_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd559a0e0a55d887e7729ecc93adba892271dac --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f0f7785d9296fdba3169212350218846_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5f18fdb7088aece39dde19c3694ad63ae4b0c43f93a21d11e9f68420192ed424 +size 79411 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f14905a438a9ec0ce711db0a20e8dc49_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f14905a438a9ec0ce711db0a20e8dc49_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6a1d9e4f71b28ceafed4bc619da5834eda2f7abe --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f14905a438a9ec0ce711db0a20e8dc49_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f173d942f55de5bac19785989050544b3d98988cbad4b896a265ff2b186e3acf +size 57529 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f457e54b77f9640321021ed52e40acae_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f457e54b77f9640321021ed52e40acae_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e7bda49833903a028e3dd5adf71e2789758b035f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f457e54b77f9640321021ed52e40acae_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a4f5f71de7b22c1a3460884669014e5c26a58aa39fe90fe63d90417d2287fed7 +size 69301 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f45e3c6000b944e206d6a7f4618b9d03_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f45e3c6000b944e206d6a7f4618b9d03_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..325c5bbc8e39f0f78e8bb7e6609e99f9f86501a8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f45e3c6000b944e206d6a7f4618b9d03_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:47a8a5ee35a550475139d11c87e6558a59d89675c0be2b852ade086b9187580e +size 20504 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f51ee5a828b83bb23778bc297d333ff9_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f51ee5a828b83bb23778bc297d333ff9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6ee6a93d0de06e692130aa457e4af02e7fd94fee --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f51ee5a828b83bb23778bc297d333ff9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f7bca777a5a3e1542e3427cf6b47d41562fb3e0621cf49e64e1df12b5c1504e3 +size 96017 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f69780aa874dd1a3d6aea91bc12b1aa2_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f69780aa874dd1a3d6aea91bc12b1aa2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f1b4e4a1721c0e5c7073bc86c5e7e75dbe811539 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f69780aa874dd1a3d6aea91bc12b1aa2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c9deebad4caefcee45ab3bbcf8ad7cf12791046033e527356966b317b64c63b4 +size 4522 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f7f50348cbcfb7b3a3295caf531eb069_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f7f50348cbcfb7b3a3295caf531eb069_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..67ce0efcabb74455e8bf59060238c96abd34a51d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/f7f50348cbcfb7b3a3295caf531eb069_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bf1516e8c678780961f4832316ed3cd6ab2e312399a60f851ffbccb3fc904c5c +size 66004 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ff8a43a251227f166e53a681a24cb87f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ff8a43a251227f166e53a681a24cb87f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..70eba064df16dd44d88030791f71f64b06ed9525 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/ff8a43a251227f166e53a681a24cb87f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:153779ac3c295d6c17ff50b0fa213fd90be50d709f89e4ac4f9d4fde0572bb2d +size 51089 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/raw.md b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..a8f8f8c0b21d702ba5d02e694f61710477d4b1cc --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00/raw.md @@ -0,0 +1,3561 @@ + + +# O-RAN WG7 + +## Hardware Reference Design Specification for Indoor Picocell (FR1) with Split Architecture Option 7-2 + +--- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# O-RAN WG7 + +## Hardware Reference Design Specification for Indoor Picocell (FR1) with Split Architecture Option 7-2 --- + +Copyright © 2021 by O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in the Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +1 + +# --- Revision History + +| Date | Revision | Author | Description | +|------------|----------|--------|-------------------------| +| 07/12/2021 | V03.00 | WG7 | Final Published Version | + +2 + +3 + +# Contents + +| | | | | +|----|---------------------------------------------|---------------------------------------------------------------|----| +| 1 | Revision History ..... | | 2 | +| 2 | Chapter 1 Introductory Material ..... | | 8 | +| 3 | 1.1 | Scope..... | 8 | +| 4 | 1.2 | References..... | 8 | +| 5 | 1.3 | Definitions and Abbreviations ..... | 9 | +| 6 | 1.3.1 | Definitions..... | 9 | +| 7 | 1.3.2 | Abbreviations ..... | 9 | +| 8 | Chapter 2 Hardware Reference Design 1 ..... | | 13 | +| 9 | 2.1 | O-CU Hardware Reference Design ..... | 13 | +| 10 | 2.2 | O-DU <sub>7-2</sub> Hardware Reference Design..... | 13 | +| 11 | 2.2.1 | O-DU <sub>7-2</sub> High-Level Functional Block Diagram ..... | 13 | +| 12 | 2.2.2 | O-DU <sub>7-2</sub> Hardware Design Description..... | 14 | +| 13 | 2.2.3 | O-DU <sub>7-2</sub> Hardware Components ..... | 15 | +| 14 | 2.2.3.1 | Digital Processing Unit..... | 15 | +| 15 | 2.2.3.2 | Hardware Accelerator..... | 16 | +| 16 | 2.2.3.2.1 | Accelerator Design Solution 1 ..... | 16 | +| 17 | 2.2.3.2.2 | Accelerator Design Solution 2 ..... | 18 | +| 18 | 2.2.3.2.3 | Accelerator Design Solution 3 ..... | 21 | +| 19 | 2.2.3.3 | Baseboard Management Controller ..... | 23 | +| 20 | 2.2.4 | Synchronization and Timing ..... | 23 | +| 21 | 2.2.4.1 | Synchronization and Timing Design 1 ..... | 23 | +| 22 | 2.2.4.2 | Synchronization and Timing Design 2 ..... | 24 | +| 23 | 2.2.5 | External Interface Ports ..... | 24 | +| 24 | 2.2.6 | O-DU <sub>7-2</sub> Firmware ..... | 25 | +| 25 | 2.2.7 | Mechanical ..... | 25 | +| 26 | 2.2.8 | Power Unit..... | 27 | + +| | | | | +|----|-----------|--------------------------------------------------------------|----| +| 1 | 2.2.9 | Thermal ..... | 28 | +| 2 | 2.2.10 | Environmental and Regulations ..... | 28 | +| 3 | 2.3 | O-RU <sub>7-2</sub> Hardware Reference Design ..... | 28 | +| 4 | 2.3.1 | O-RU <sub>7-2</sub> High-Level Functional Block Diagram..... | 28 | +| 5 | 2.3.2 | O-RU <sub>7-2</sub> Hardware Components..... | 28 | +| 6 | 2.3.2.1 | Digital Processing Unit..... | 32 | +| 7 | 2.3.2.2 | RF Processing Unit..... | 35 | +| 8 | 2.3.2.2.1 | Transceiver Reference Design ..... | 35 | +| 9 | 2.3.2.2.2 | Power Amplifier (PA) Reference Design ..... | 41 | +| 10 | 2.3.2.2.3 | Low Noise Amplifier (LNA) Reference Design..... | 42 | +| 11 | 2.3.2.2.4 | RF Switch Reference Design ..... | 45 | +| 12 | 2.3.2.2.5 | Antenna Reference Design ..... | 46 | +| 13 | 2.3.3 | Synchronization and Timing ..... | 47 | +| 14 | 2.3.4 | External Interface Ports ..... | 50 | +| 15 | 2.3.5 | Mechanical ..... | 51 | +| 16 | 2.3.6 | Power Unit..... | 52 | +| 17 | 2.3.7 | Thermal ..... | 53 | +| 18 | 2.3.8 | Environmental and Regulations ..... | 53 | +| 19 | 2.4 | FHGW <sub>7-2</sub> Hardware Reference Design ..... | 54 | +| 20 | 2.4.1 | FHGW <sub>7-2</sub> High-Level Functional Block Diagram..... | 54 | +| 21 | 2.4.2 | FHGW <sub>7-2</sub> Hardware Components..... | 55 | +| 22 | 2.4.2.1 | Digital Processing Unit..... | 55 | +| 23 | 2.4.3 | Synchronization and Timing ..... | 57 | +| 24 | 2.4.4 | External Interface Ports ..... | 58 | +| 25 | 2.4.5 | Mechanical ..... | 59 | +| 26 | 2.4.6 | Power..... | 60 | +| 27 | 2.4.7 | Thermal ..... | 60 | +| 28 | 2.4.8 | Environmental and Regulations ..... | 60 | + +| | | | | +|----|---------|---------------------------------------------------------------------------------------------|-----| +| 1 | 2.5 | FHGW <sub>7-2→8</sub> Hardware Reference Design ..... | 61 | +| 2 | 2.5.1 | FHGW <sub>7-2→8</sub> High-Level Functional Block Diagram ..... | 61 | +| 3 | 2.5.2 | FHGW <sub>7-2→8</sub> Hardware Components ..... | 62 | +| 4 | 2.5.2.1 | Digital Processing Unit ..... | 62 | +| 5 | 2.5.3 | Synchronization and Timing ..... | 64 | +| 6 | 2.5.4 | External Interface Ports ..... | 65 | +| 7 | 2.5.5 | Mechanical ..... | 67 | +| 8 | 2.5.6 | Power ..... | 67 | +| 9 | 2.5.7 | Thermal ..... | 68 | +| 10 | 2.5.8 | Environmental and Regulations ..... | 68 | +| 11 | | Annex 1: Parts Reference List ..... | 69 | +| 12 | | Annex 2: FHGW <sub>7-2→8</sub> Option 8 CPRI specification reference design ..... | 70 | +| 13 | | Annex 3: FHGW <sub>7-2→8</sub> Option 8 CPRI spec reference design – Management plane ..... | 70 | +| 14 | | Annex 4: FHGW <sub>7-2→8</sub> management plane reference design ..... | 70 | +| 15 | | Annex ZZZ: O-RAN Adopter License Agreement ..... | 109 | +| 16 | | Section 1: DEFINITIONS ..... | 109 | +| 17 | | Section 2: COPYRIGHT LICENSE ..... | 110 | +| 18 | | Section 3: FRAND LICENSE ..... | 110 | +| 19 | | Section 4: TERM AND TERMINATION ..... | 111 | +| 20 | | Section 5: CONFIDENTIALITY ..... | 111 | +| 21 | | Section 6: INDEMNIFICATION ..... | 111 | +| 22 | | Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 111 | +| 23 | | Section 8: ASSIGNMENT ..... | 112 | +| 24 | | Section 9: THIRD-PARTY BENEFICIARY RIGHTS ..... | 112 | +| 25 | | Section 10: BINDING ON AFFILIATES ..... | 112 | +| 26 | | Section 11: GENERAL ..... | 112 | + +27 + +## Tables + +| | | | +|----|---------------------------------------------------------------------------------|----| +| 1 | | | +| 2 | Table 2-1: The Processor Feature List ..... | 15 | +| 3 | Table 2-2: The Memory Channel Feature List ..... | 15 | +| 4 | Table 2-3: Accelerator Hardware Feature List ..... | 16 | +| 5 | Table 2-4: Accelerator Firmware Feature List..... | 17 | +| 6 | Table 2-5: Accelerator Hardware Component List..... | 19 | +| 7 | Table 2-6: Accelerator Hardware Feature List ..... | 22 | +| 8 | Table 2-7: Accelerator Firmware Feature List..... | 22 | +| 9 | Table 2-8: External Port List..... | 24 | +| 10 | Table 2-9: Power supply unit feature list..... | 28 | +| 11 | Table 2-10: Environmental Features..... | 28 | +| 12 | Table 2-11: Resource requirement for 2T2R O-RU <sub>7-2</sub> ..... | 32 | +| 13 | Table 2-12: Resource requirement for 4T4R O-RU <sub>7-2</sub> ..... | 32 | +| 14 | Table 2-13: Interface requirements of the Transceiver..... | 35 | +| 15 | Table 2-14: Payload with DPD in Digital Device (GBPS Rx/Tx)..... | 36 | +| 16 | Table 2-15: Payload with DPD in Transceiver (GBPS Rx/Tx) ..... | 36 | +| 17 | Table 2-16: RF specifications in Transceiver ..... | 37 | +| 18 | Table 2-17: PA Requirements..... | 41 | +| 19 | Table 2-18: Interface requirements of the transmit PA ..... | 41 | +| 20 | Table 2-19: One stage LNA Requirements..... | 42 | +| 21 | Table 2-20: Two stage LNA Requirements ..... | 43 | +| 22 | Table 2-21: Interface requirements of the RF switch ..... | 45 | +| 23 | Table 2-22: RF Switch Requirements..... | 45 | +| 24 | Table 2-23: Antenna Requirements ..... | 46 | +| 25 | Table 2-24: Interface requirements of the clocking..... | 47 | +| 26 | Table 2-25: Clocking RF requirements..... | 48 | +| 27 | Table 2-26: External Port List..... | 50 | +| 28 | Table 2-27: power unite requirement for 2T2R and 4T4R O-RU <sub>7-2</sub> ..... | 52 | +| 29 | Table 2-28: Power unite function ..... | 52 | +| 30 | Table 2-29: Environmental Features..... | 53 | +| 31 | Table 2-30: Interface requirements of the FPGA ..... | 55 | +| 32 | Table 2-31: FPGA Resource usage for FHGW <sub>7-2</sub> ..... | 56 | +| 33 | Table 2-32: Requirements of the PLL device ..... | 57 | +| 34 | Table 2-33: External Port List..... | 58 | +| 35 | Table 2-34: Requirements of the power unit ..... | 60 | +| 36 | Table 2-35: Interface Requirements of the FPGA ..... | 62 | +| 37 | Table 2-36: FPGA Resource Usage for FHGW <sub>7-2→8</sub> ..... | 63 | +| 38 | Table 2-37: Requirements of the PLL device ..... | 64 | +| 39 | Table 2-38: External Port List..... | 65 | +| 40 | Table 2-39: Power Unit Requirements ..... | 68 | + +1 + +# Figures + +| | | | +|----|------------------------------------------------------------------------------------------------------|----| +| 3 | Figure 2-1: O-DU <sub>7.2</sub> Functional Block Diagram..... | 14 | +| 4 | Figure 2-2: O-DU <sub>7.2</sub> Hardware Block Diagram..... | 14 | +| 5 | Figure 2-3: Accelerator Design 1 without optional NIC Device ..... | 18 | +| 6 | Figure 2-4: Accelerator Design 1 with optional NIC Device ..... | 18 | +| 7 | Figure 2-5: Example 2-chip FPGA-based Hardware Acceleration in O-DU <sub>7.2</sub> ..... | 21 | +| 8 | Figure 2-6: Structured ASIC Accelerator Design..... | 23 | +| 9 | Figure 2-7: O-DU <sub>7.2</sub> Timing Synchronization ..... | 24 | +| 10 | Figure 2-8: HW Acceleration Board Timing and Synchronization..... | 24 | +| 11 | Figure 2-9: External interfaces reference design ..... | 25 | +| 12 | Figure 2-10: Mother Board Layout Diagram..... | 26 | +| 13 | Figure 2-11: Chassis Mechanical Diagram..... | 27 | +| 14 | Figure 2-12: High-Level Functional Block Diagram..... | 28 | +| 15 | Figure 2-13: 2T2R General Block Diagram with TR switch..... | 29 | +| 16 | Figure 2-14: 4T4R General Block Diagram with TR switch..... | 29 | +| 17 | Figure 2-15: Power estimation for 2T2R O-RU <sub>7.2</sub> ..... | 31 | +| 18 | Figure 2-16: Power estimation for 4T4R O-RU <sub>7.2</sub> ..... | 32 | +| 19 | Figure 2-17: FPGA Reference Design Diagram..... | 32 | +| 20 | Figure 2-18: Transceiver Reference Design Diagram (Optional elements are highlighted in Grey ) ..... | 40 | +| 21 | Figure 2-19: PA Reference Design Diagram ..... | 42 | +| 22 | Figure 2-20: One Stage LNA Diagram..... | 44 | +| 23 | Figure 2-21: Two-Stage LNA Diagram..... | 44 | +| 24 | Figure 2-22: RF Switch Reference Design Diagram ..... | 46 | +| 25 | Figure 2-23: Whip Antenna ..... | 47 | +| 26 | Figure 2-24: PLL Reference Design Diagram ..... | 49 | +| 27 | Figure 2-25: SFP+ case and connector ..... | 50 | +| 28 | Figure 2-26: RJ45 interface ..... | 51 | +| 29 | Figure 2-27: O-RU <sub>7.2</sub> Shell Mechanical Diagram..... | 51 | +| 30 | Figure 2-28: PoE Reference Design Diagram ..... | 53 | +| 31 | Figure 2-29: FHGW <sub>7.2</sub> General Block Diagram ..... | 54 | +| 32 | Figure 2-30: FHGW <sub>7.2</sub> Digital Processing Block Diagram ..... | 56 | +| 33 | Figure 2-31: CLK reference design for FHGW <sub>7.2</sub> ..... | 57 | +| 34 | Figure 2-32: SFP+ case and connector ..... | 58 | +| 35 | Figure 2-33: RJ45 interface ..... | 59 | +| 36 | Figure 2-34: AC power interface ..... | 59 | +| 37 | Figure 2-35: Shell Mechanical Diagram..... | 59 | +| 38 | Figure 2-36: FHGW <sub>7.2→8</sub> General Block Diagram ..... | 61 | +| 39 | Figure 2-37: FHGW <sub>7.2→8</sub> Digital Processing Block Diagram..... | 63 | + +| | | | +|---|-------------------------------------------------------------------|----| +| 1 | Figure 2-38: CLK reference design for FHGW <sub>7-2→8</sub> ..... | 64 | +| 2 | Figure 2-39: SFP+ case and connector ..... | 65 | +| 3 | Figure 2-40: RJ45 interface ..... | 66 | +| 4 | Figure 2-41: AC power interface ..... | 66 | +| 5 | Figure 2-42: Shell Mechanical Diagram..... | 67 | +| 6 | | | +| 7 | | | + +# Chapter 1 Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG7 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. This variable is for internal WG7 use only. + +The present document specifies system requirements and high-level architecture for the FR1 Picocell Indoor deployment scenario as specified in the Deployment Scenarios and Base Station Classes document [1]. + +In the main body of this specification (in any “chapter”) the information contained therein is informative, unless explicitly described as normative. Information contained in an “Annex” to this specification is always informative unless otherwise marked as normative. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- [1] ORAN-WG7.DSC.0-V01.00 Technical Specification, ‘Deployment Scenarios and Base Station Classes for White Box Hardware’. <https://www.o-ran.org/specifications> +- [2] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [3] 3GPP TR 38.104: "NR; Base Station (BS) radio transmission and reception". +[http://www.3gpp.org/ftp/Specs/archive/38\\_series/38.104/38104-g10.zip](http://www.3gpp.org/ftp/Specs/archive/38_series/38.104/38104-g10.zip) +- [4] ORAN-WG4.CUS.0-v01.00 Technical Specification, ‘O-RAN Fronthaul Working Group Control, User and Synchronization Plane Specification’. <https://www.o-ran.org/specifications> +- [5] 3GPP TS 38.113:"NR: Base Station (BS) Electromagnetic Compatibility (EMC)". +[http://www.3gpp.org/ftp/Specs/archive/38\\_series/38.113/38113-f80.zip](http://www.3gpp.org/ftp/Specs/archive/38_series/38.113/38113-f80.zip) + +- [6] ORAN-WG7. IPC. HAR-v01.00 Technical Specification, ‘Indoor Pico Cell Hardware Architecture and Requirement Specification’. <https://www.o-ran.org/specifications>. +- [7] ORAN-WG7. IPC. HRD.O8-v03.00 Technical Specification, ‘Indoor Pico Cell BS Hardware Reference Design Specifications with Fronthaul Split Option 8 and FR1’. <https://www.o-ran.org/specifications> + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [2]. For the base station classes of Pico, Micro and Macro, the definitions are given in 3GPP TR 38.104 [3]. + +**Carrier Frequency:** Center frequency of the cell. + +**F1 interface:** The open interface between O-CU and O-DU<sub>7-2</sub> as defined by 3GPP TS 38.473 between CU and DU. + +**Integrated architecture:** In the integrated architecture, the O-RU and O-DU<sub>x</sub> are implemented on one platform. Each O-RU and RF front end is associated with one O-DU<sub>7-2</sub>. They are then aggregated to O-CU and connected by F1 interface. + +**Split architecture:** The O-RU<sub>x</sub> and O-DU<sub>x</sub> are physically separated from one another in this architecture. A switch may aggregate multiple O-RU<sub>x</sub>s to one O-DU<sub>x</sub>. O-DU<sub>x</sub> switch and O-RU<sub>x</sub>s are connected by the fronthaul interface as defined in WG4. + +**Transmission Reception Point (TRxP):** Antenna array with one or more antenna elements available to the network located at a specific geographical location for a specific area. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in [2] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, as in [2]. + +| | | +|-------|------------------------------------------------------------------------------------| +| 7-2 | Fronthaul interface split option as defined by O-RAN WG4, also referred to as 7-2x | +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth-Generation Mobile Communications | +| 5GC | 5G Core | +| ACS | Adjacent Channel Selectivity | +| ADC | Analog to Digital Converter | +| ASIC | Application Specific Integrated Circuit | +| ATA | Advanced Technology Attachment | +| BBDEV | Baseband Device | +| BH | Backhaul | +| BMC | Baseboard Management Controller | + +| | | | +|----|---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | BPSK | Binary Phase Shift Keying | +| 2 | BS | Base Station | +| 3 | CISPR | International Special Committee on Radio Interference | +| 4 | CFR | Crest Factor Reduction | +| 5 | CU | Centralized Unit as defined by 3GPP | +| 6 | COM | Cluster Communication | +| 7 | CPRI | Common Public Radio Interface | +| 8 | CPU | Central Processing Unit | +| 9 | CRC | Cyclic Redundancy Check | +| 10 | DAC | Digital to Analog Converter | +| 11 | DDC | Digital Down Conversion | +| 12 | DDR | Double Data Rate | +| 13 | DIMM | Dual-Inline-Memory-Modules | +| 14 | DL | Downlink | +| 15 | DPD | Digital Pre-Distortion | +| 16 | DPDK | Data Plane Development Kit | +| 17 | DSP | Digital Signal Processor | +| 18 | DU | Distributed Unit as defined by 3GPP | +| 19 | DUC | Digital Up Conversion | +| 20 | ECC | Error Correcting Code | +| 21 | eCPRI | evolved Common Public Radio Interface | +| 22 | EMC | Electro Magnetic Compatibility | +| 23 | EVM | Error Vector Magnitude | +| 24 | FCC | Federal Communications Commission | +| 25 | FEC | Forward Error Correction | +| 26 | FFT | Fast Fourier Transform | +| 27 | FH | Fronthaul | +| 28 | FHGW | Fronthaul Gateway | +| 29 | FHM <sub>x</sub> | Fronthaul Multiplexer with no FH protocol translation, supporting an O-DU <sub>x</sub> with split option x and an O-RU <sub>x</sub> with split option x, with currently available options 6→6, 7-2→7-2 and 8→8 | +| 30 | | | +| 31 | FHGW <sub>x→y</sub> | Fronthaul Gateway that can translate fronthaul protocol from an O-DU <sub>x</sub> with split option x to an O-RU <sub>y</sub> with split option y, with currently available option 7-2→8. | +| 32 | | | +| 33 | FHHL | Full Height Half Length | +| 34 | FPGA | Field Programmable Gate Array | +| 35 | GbE | Gigabit Ethernet | +| 36 | GNSS | Global Navigation Satellite System | +| 37 | GPP | General Purpose Processor | +| 38 | GPS | Global Positioning System | +| 39 | HARQ | Hybrid Automatic Repeat request | +| 40 | HHHL | Half Height Half Length | +| 41 | IEEE | Institute of Electrical and Electronics Engineers | + +| | | | +|----|-------------------|-----------------------------------------------------------------------------------------------------| +| 1 | IFFT | Inverse Fast Fourier Transform | +| 2 | IMD | Inter Modulation Distortion | +| 3 | I/O | Input/Output | +| 4 | JTAG | Joint Test Action Group | +| 5 | L1 | Layer 1 | +| 6 | LDPC | Low-Density Parity Codes | +| 7 | LRDIMM | Load-Reduced Dual In-line Memory Module | +| 8 | LTE | Long Term Evolution | +| 9 | LVDS | Low-Voltage Differential Signaling | +| 10 | MAC | Media Access Control | +| 11 | MCP | Multi-Chip Package | +| 12 | MH | Midhaul | +| 13 | MIG | Memory Interface Generator | +| 14 | MII | Media-Independent interface | +| 15 | MIMO | Multiple Input Multiple Output | +| 16 | MU-MIMO | Multiple User MIMO | +| 17 | NEBS | Network Equipment-Building System | +| 18 | NetConf | Network Configuration Protocol | +| 19 | NFV | Network Functions Virtualization | +| 20 | NIC | Network Interface Controller | +| 21 | NR | New Radio | +| 22 | O-CU | O-RAN Centralized Unit as defined by O-RAN | +| 23 | O-DU <sub>x</sub> | A specific O-RAN Distributed Unit having fronthaul split option x where x may be 6, 7-2 (as | +| 24 | | defined by WG4) or 8 | +| 25 | O-RU <sub>x</sub> | A specific O-RAN Radio Unit having fronthaul split option x, where x is 6, 7-2 (as defined by | +| 26 | | WG4) or 8, and which is used in a configuration where the fronthaul interface is the same at the O- | +| 27 | | DU <sub>x</sub> | +| 28 | OCXO | Oven Controlled Crystal Oscillator | +| 29 | PCIe | Peripheral Component Interface Express | +| 30 | PDCP | Packet Data Convergence Protocol | +| 31 | PHY | Physical Layer | +| 32 | PMBus | Power Management Bus | +| 33 | POE | Power over Ethernet | +| 34 | PPS | Pulse Per Second | +| 35 | PRACH | Physical Random Access Channel | +| 36 | QAM | Quadrature Amplitude Modulation | +| 37 | QPSK | Quadrature Phase Shift Keying | +| 38 | QSFP | Quad Small Form-factor Pluggable | +| 39 | RAN | Radio Access Network | +| 40 | RDIMM | Registered Dual In-line Memory Module | +| 41 | RF | Radio Frequency | + +| | | | +|----|------|-------------------------------------------| +| 1 | RoE | Radio over Ethernet | +| 2 | RU | Radio Unit as defined by 3GPP | +| 3 | RX | Receiver | +| 4 | SATA | Serial ATA | +| 5 | SDU | Service Data Unit | +| 6 | SFP | Small Form-factor Pluggable | +| 7 | SFP+ | Small Form-factor Pluggable plus | +| 8 | SOC | System On Chip | +| 9 | SPI | Serial Peripheral Interface | +| 10 | SSD | Solid State Drive | +| 11 | TCXO | Temperature Compensate Crystal Oscillator | +| 12 | TDP | Thermal Design Power | +| 13 | TR | Technical Report | +| 14 | TS | Technical Specification | +| 15 | TX | Transmitter | +| 16 | UL | Uplink | +| 17 | USB | Universal Serial Bus | +| 18 | WG | Working Group | +| 19 | | | + +# Chapter 2 Hardware Reference Design 1 + +This chapter describes a white box hardware reference design example for indoor Picocell deployment scenario. It includes O-CU, O-DU<sub>7-2</sub> and FHM<sub>7-2</sub>/FHGW<sub>7-2→8</sub> for IPC deployment scenario. + +## 2.1 O-CU Hardware Reference Design + +The O-CU white box hardware is the platform that perform the O-CU function of upper L2 and L3. The hardware systems specified in this document meet the computing, power and environmental requirements of use cases configurations and feature sets of RAN physical node. These requirements are described in the early hardware requirement specification as well as in the use cases document. The O-CU hardware includes the chassis platform, mother board, peripheral devices and cooling devices. The mother board contains processing unit, memory, the internal I/O interfaces, and external connection ports. The midhaul (MH) and backhaul (BH) interface are used to carry the traffic between O-CU and O-DU<sub>7-2</sub> as well as O-CU and core network. The other hardware functional components include: the storage for software, hardware and system debugging interfaces, board management controller, just to name a few; the O-CU designer will make decision based on the specific needs of the implementation. + +The HW reference design of O-CU is the same as O-DU<sub>7-2</sub> except for the need of HW accelerator, thus detail design will be described in O-DU<sub>7-2</sub> section 2.2. + +## 2.2 O-DU<sub>7-2</sub> Hardware Reference Design + +The O-DU<sub>7-2</sub> white box hardware is the platform that performs the O- DU<sub>7-2</sub> functions such as upper L1 and lower L2 functions. The hardware systems specified in this document meet the computing, power and environmental requirements of use case's configurations and feature sets of RAN physical node. These requirements are described in the early hardware requirement specification as well as in the use cases document. The O-DU<sub>7-2</sub> hardware includes the chassis platform, mother board, peripheral devices and cooling devices. The mother board contains processing unit, memory, the internal I/O interfaces, and external connection ports. The fronthaul and backhaul interface are used to carry the traffic between O-RU<sub>7-2</sub>/FHM<sub>7-2</sub>/FHGW<sub>7-2→8</sub> and O-DU<sub>7-2</sub> as well as O-CU and O-DU<sub>7-2</sub>. The O-DU<sub>7-2</sub> design may also provide an interface for hardware accelerator if that option is preferred. The other hardware functional components include: the storage for software, hardware and system debugging interfaces, board management controller, just to name a few; the O-DU<sub>7-2</sub> designer will make decision based on the specific needs of the implementation. + +Note that the O-DU<sub>7-2</sub> HW reference design is also feasible for O-CU and integrated O-CU/ O-DU<sub>7-2</sub>. + +### 2.2.1 O-DU<sub>7-2</sub> High-Level Functional Block Diagram + +Figure 2-1 shows the major functional blocks of O-DU<sub>7-2</sub>. The digital processing unit handles the baseband processing workload. To make the processing more efficient, an accelerator can be used to assist with the baseband workload processing. The memory devices include the random-access memory (RAM) for temporary storage of data while flash memory is used for codes and logs. The storage device is for persistent storage. The external network cards can be used + +for fronthaul or backhaul connection. The baseboard management controller (BMC) is a microcontroller which monitors hardware operation on motherboard. The clock circuits provide digital processing unit with required clock signals. + +![Figure 2-1: O-DU7-2 Functional Block Diagram. The diagram shows a central 'Digital Processing Unit' block connected to several peripheral components: 'Accelerator', 'Baseboard Management Controller', and 'Clock' on the left; and 'DDR RAM', 'Flash Memory', 'Storage Drives', and 'Ethernet Card' on the right. All connections are bidirectional.](044d61a1766d41f0d7179f39cbeb061d_img.jpg) + +``` + +graph LR + subgraph O-DU7-2 [O-DU7-2] + Accelerator <--> DPU[Digital Processing Unit] + BMC[Baseboard Management Controller] <--> DPU + Clock <--> DPU + DPU <--> DDR[DDR RAM] + DPU <--> Flash[Flash Memory] + DPU <--> Storage[Storage Drives] + DPU <--> Ethernet[Ethernet Card] + end + +``` + +Figure 2-1: O-DU7-2 Functional Block Diagram. The diagram shows a central 'Digital Processing Unit' block connected to several peripheral components: 'Accelerator', 'Baseboard Management Controller', and 'Clock' on the left; and 'DDR RAM', 'Flash Memory', 'Storage Drives', and 'Ethernet Card' on the right. All connections are bidirectional. + +**Figure 2-1: O-DU<sub>7-2</sub> Functional Block Diagram.** + +### 2.2.2 O-DU<sub>7-2</sub> Hardware Design Description + +Figure 2-2 describes the various components and connections inside the O-DU<sub>7-2</sub> white box. + +![Figure 2-2: O-DU7-2 Hardware Block Diagram. This diagram illustrates the hardware architecture of the O-DU7-2. At the center is the 'SoC CPU' (U1). It is connected to four DDR4 memory modules (1866/2133/2400/2666) labeled E1, D1, A1, and B1. The SoC CPU is also connected to a 'PCH' (Platform Controller Hub) which manages various I/Os. Key components include: an 'Accelerator' connected via PCIe 3.0 x16; a 'NIC' (Network Interface Card) connected via 10G PHY and KR; multiple 'JLAN' (Joint LAN) ports (JLAN1, JLAN2, JLAN3, JLAN4) connected via PCIe 3.0 x1, x2, and x4; a 'USB 3.0 Rear I/O' connected via USB 3.0/2.0; several 'M.2' storage connectors (B-key, E-key, M-key) connected via PCIe 3.0; a 'USB 2.0 HUB' connected via USB 2.0; a 'BMC' (Baseboard Management Controller) connected via eSPI and PCIe 3.0 x1; and various headers including JTPM1, SATA3.0, and COM1/2. The diagram also shows a 'REAR IO' section with COM, USB3.0, 3rd LAN, 1G LAN SFP+, 10G LAN, and 1G LAN(2x4) ports.](d2b50923402c459a04b7d61e8211321c_img.jpg) + +Figure 2-2: O-DU7-2 Hardware Block Diagram. This diagram illustrates the hardware architecture of the O-DU7-2. At the center is the 'SoC CPU' (U1). It is connected to four DDR4 memory modules (1866/2133/2400/2666) labeled E1, D1, A1, and B1. The SoC CPU is also connected to a 'PCH' (Platform Controller Hub) which manages various I/Os. Key components include: an 'Accelerator' connected via PCIe 3.0 x16; a 'NIC' (Network Interface Card) connected via 10G PHY and KR; multiple 'JLAN' (Joint LAN) ports (JLAN1, JLAN2, JLAN3, JLAN4) connected via PCIe 3.0 x1, x2, and x4; a 'USB 3.0 Rear I/O' connected via USB 3.0/2.0; several 'M.2' storage connectors (B-key, E-key, M-key) connected via PCIe 3.0; a 'USB 2.0 HUB' connected via USB 2.0; a 'BMC' (Baseboard Management Controller) connected via eSPI and PCIe 3.0 x1; and various headers including JTPM1, SATA3.0, and COM1/2. The diagram also shows a 'REAR IO' section with COM, USB3.0, 3rd LAN, 1G LAN SFP+, 10G LAN, and 1G LAN(2x4) ports. + +Figure 2-2: O-DU<sub>7-2</sub> Hardware Block Diagram + +As described in the previous section, the O-DU<sub>7-2</sub> hardware can be implemented with difference design choices. Here, we use a SoC design-based as an example which performs most of the workload for O-DU<sub>7-2</sub>. The accelerator can be used to perform other functions based on the overall performance requirement. Several Ethernet controllers are also used for front haul link, back haul link and remote console control connection. The other parts include: RAM, flash memory, and hard drive storage. The JTAG and USB ports are provided for hardware debug and local connection if needed. Finally, BMC block is mainly responsible for monitoring the hardware status of the motherboard. + +### 2.2.3 O-DU<sub>7-2</sub> Hardware Components + +In this section, we describe the details of the O-DU<sub>7-2</sub> hardware component's requirements, their features and parameters. The component selection is based on the use case requirements which are listed in the hardware architecture and requirements document [6]. + +#### 2.2.3.1 Digital Processing Unit + +This example of the digital processing unit in O-DU<sub>7-2</sub> is based on the General Purpose Processor (GPP). + +##### a. Digital Processing Unit Requirement + +The GPP requirements are listed in the following table. + +Table 2-1: The Processor Feature List + +| Item Name | Description | +|------------|-------------| +| # of Cores | 16 | + +| | | +|--------------------------------------------|----------| +| # of Threads | 32 | +| Base Frequency | 2.20 GHz | +| Max Turbo Frequency | 3.00 GHz | +| Cache | 22 MB | +| Thermal Design Power (TDP) | 100W | +| Max Memory Size (dependent on memory type) | 512 GB | +| Memory Types | DDR4 | +| Max # of Memory Channels | 4 | + +**Interfaces:** The interface specification on the main board are as follows: + +**Memory Channel Interfaces:** The system memory capacity, type and related information are described in the following table. + +**Table 2-2: The Memory Channel Feature List** + +| Item Name | Description | +|----------------------|-------------------------| +| Memory Types | DDR4 | +| # of Memory Channels | 4 | +| ECC LRDIMM | Up to 512GB | +| ECC RDIMM | Up to 256GB | +| Memory Speed | 2666/2400/2133MHz | +| DIMM Sizes | 128GB, 64GB, 32GB, 16GB | +| Memory Voltage | 1.2 V | + +**PCIe:** PCIe Gen 3 should be supported by the processor. There are total of 32 PCIe lanes with 128 Gb/s bandwidth. The 32 PCIe lanes can be divided into two x16 slots by using a riser card. + +**Ethernet:** The system should be capable to offer aggregated 48 Gb/s Ethernet bandwidth. The breakout the ports are discussed in later section. When higher Ethernet bandwidth required, an Ethernet card can be installed in one of the PCIe slot. + +##### **b. Digital Processing Unit Design** + +The digital processing unit is a system-on-a-chip (SoC) device which is a 64-bit multi-core server class processor. This SoC includes an integrated Platform Controller Hub (PCH), integrated high-speed I/O, Integrated Memory Controllers (IMC), and four integrated 10 Gigabit Ethernet ports. + +The SOC supports 512-bit wide vector processing instruction set. It also supports hardware virtualization to enable dynamic provisioning of services as communication service providers extend network functions virtualization (NFV). Figure 2-2 shows the major functional blocks of the digital processing unit. + +#### **2.2.3.2 Hardware Accelerator** + +Hardware accelerators can be used in O-DU<sub>7-2</sub> to offload computationally intensive functions and to optimize the performance under varying traffic and loading conditions. The acceleration functional requirements and implementation are system designer's choice; however, the O-DU<sub>7-2</sub> shall meet the minimum system performance requirements under various loading and deployment conditions. In most cases, a Field Programmable Gate Array (FPGA) or Application Specific Integrated Circuit (ASIC) based PCIe card can be used to optimize the system performance. The FPGA(s) are part of a Network Interface Controller (NIC) that further provides connectivity services. + +##### 2.2.3.2.1 Accelerator Design Solution 1 + +Channel coding for Low-Density Parity Codes (LDPC) and fronthaul compression requires a significant amount of bit level processing and is well suited to a fine-grained FPGA architecture and/or low cost/power structured ASIC. Options include: + +- Virtualization: Multi-channel DMA, Virtual machine integration, load balancing functions +- Look-aside FEC: LDPC (de)coding, Polar (de)coding, Rate (De)Matcher, (De) Interleaver, Cyclic Redundancy Check (CRC), Hybrid Automatic Repeat request (HARQ) retransmission +- Bump-in-wire Fronthaul: compression / decompression for latency and bandwidth reduction + +###### a. Accelerator Requirements + +Hardware and firmware requirements for this accelerator design are given in Table 2-3 and Table 2-4, respectively. + +**Table 2-3: Accelerator Hardware Feature List** + +| Item Name | Description | +|-----------------------------------------------|----------------------------------------------------------------------------------------------------| +| PCIe (Interface with digital processing unit) | Gen4 x16 (and lower) | +| Form factor | FHHL | +| Connectivity | 2x QSFP28/56 | +| FPGA | Logic Elements: 1437K<br>M20K Memory: 139Mb<br>Quad A53 Hard Processor Sub-system | +| NIC Device | 100Gb xHAUL for FH, BH & MH traffic shaping. Optional FPGA co-processing. | +| DDR Main | 8+8+1GB DDR4 | +| Flash (FPGA images) | >=1 Gbit | +| BMC | Telemetry, Security, remote upgrade | +| Clocking | For O-RAN C1, C2, C3 & C4 | +| Fronthaul | eCPRI, RoE IEEE1914.3, O-RAN WG4 | +| GPS | SMA for 1 PPS & 10MHz (in/out) | +| Operating Temperature (ambient) | NEBS Compliant | +| Power | <75W (without optional NIC device) | +| Clock Accuracy | Low-Jitter, configurable clock ranging from 10MHz to 750MHz.<br>Option for OCXO (TCXO as standard) | + +**Table 2-4: Accelerator Firmware Feature List** + +| Item Name | Description | +|--------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Remote system upgrade | Securely upgradable FPGA flash image | +| Queuing | 64 Queues supported equally split between UL & DL. | +| LDPC Acceleration | NR LDPC Encoding with, interleaving and rate-matching.<br>NR LDPC Decoding with sub-block de-interleaving function of reverse rate matching.<br>Early Termination, CRC attachment and HARQ buffering.<br>5G Throughput: DL 14.8Gbps, UL 3.2Gbps | +| Load Balancing (channel coding) | Load balancer distributes the pending encoder/decoder requests to encoder/decoders | +| Descriptor Format (channel coding) | Code block based interface.<br>Software enablement by BBDEV API (DPDK)<br><a href="https://www.dpdk.org/">https://www.dpdk.org/</a><br><a href="https://doc.dpdk.org/guides/prog_guide/bbdev.html">https://doc.dpdk.org/guides/prog_guide/bbdev.html</a> | +| Fronthaul Compression | In-line compression/decompression for Mu-Law, block-floating point and quantization according to the O-RAN WG4 specification. | +| Open programmable acceleration environment | Support for: <ul style="list-style-type: none"> <li>FPGA Flashing upgrade</li> <li>Firmware version reporting</li> <li>PCIe diagnostics</li> <li>Ethernet diagnostics</li> <li>Temperature and voltage telemetry information</li> </ul> | + +###### b. Accelerator Design + +Figure 2-3 illustrates Accelerator Design 1 without optional NIC Device. Figure 2-4 illustrates the Accelerator Design 1 with optional NIC Device. + +![Block diagram of Accelerator Design 1 without optional NIC Device. A Digital Processing Unit (L3, L2, L1 part) is connected via PCIe Gen 4x16 Or lower (200G) to an FPGA block. The FPGA block contains Connectivity & L1 Processing (C1, 2, 3, 4 Sync). The FPGA block is also connected via FH 2x2x56Gbps Or lower to an external interface. A 1PPS & 10MHz SMA signal is connected to the bottom of the FPGA block.](029c0ccafb6b3d07f7b64e7159ee520b_img.jpg) + +``` + +graph LR + DPU[Digital Processing Unit +L3,L2,L1(part)] <-->|PCIe Gen 4x16 +Or lower (200G)| FPGA + subgraph FPGA_Box [FPGA] + C1[Connectivity & L1 Processing +C1,2,3,4 Sync] + end + FPGA_Box <-->|FH 2x2x56Gbps +Or lower| Ext[ ] + FPGA_Box --- SMA[1PPS & 10MHz +SMA] + +``` + +Block diagram of Accelerator Design 1 without optional NIC Device. A Digital Processing Unit (L3, L2, L1 part) is connected via PCIe Gen 4x16 Or lower (200G) to an FPGA block. The FPGA block contains Connectivity & L1 Processing (C1, 2, 3, 4 Sync). The FPGA block is also connected via FH 2x2x56Gbps Or lower to an external interface. A 1PPS & 10MHz SMA signal is connected to the bottom of the FPGA block. + +**Figure 2-3: Accelerator Design 1 without optional NIC Device** + +![Figure 2-4: Accelerator Design 1 with optional NIC Device. The diagram shows a Digital Processing Unit (L3, L2, L1 part) connected to an FPGA (Connectivity & L1 Processing, C1, 2, 3, 4 Sync) and a NIC. The FPGA is connected to the Digital Processing Unit via PCIe Gen4x16. The FPGA is also connected to the NIC via PCIe Gen 4x8 or lower (100G). The FPGA has a 1PPS & 10MHz SMA input. The FPGA is connected to the NIC via 100Gb. The FPGA is connected to the NIC via FH 2x2x56Gbps or lower.](40a7bcfdf7ced1cfca648564df7da749_img.jpg) + +Figure 2-4: Accelerator Design 1 with optional NIC Device. The diagram shows a Digital Processing Unit (L3, L2, L1 part) connected to an FPGA (Connectivity & L1 Processing, C1, 2, 3, 4 Sync) and a NIC. The FPGA is connected to the Digital Processing Unit via PCIe Gen4x16. The FPGA is also connected to the NIC via PCIe Gen 4x8 or lower (100G). The FPGA has a 1PPS & 10MHz SMA input. The FPGA is connected to the NIC via 100Gb. The FPGA is connected to the NIC via FH 2x2x56Gbps or lower. + +**Figure 2-4: Accelerator Design 1 with optional NIC Device** + +##### 2.2.3.2.2 Accelerator Design Solution 2 + +The O-DU<sub>7-2</sub> system is typically implemented using a multi-core processor and one or more hardware accelerators. Parts of O-DU<sub>7-2</sub> protocol stack can be implemented in software running on the multi-core processors, some of the computationally intensive L1 and L2 functions are offloaded to FPGA-based or similar hardware accelerators. This is a programmable hardware, which provides both flexibility and high computing capabilities. + +###### a. Accelerator Requirement + +The accelerator unit comprises one or more FPGAs (e.g., two FPGAs), sufficient amount of DDR4 memory, and synchronization circuitry where one of FPGAs is used for L1 functional offload and the other one is used to perform fronthaul connectivity functions/protocols. The FPGA for L1 offload uses dedicated cores for channel encoding/decoding as well as FPGA and processing resources for running L1 functions such as but not limited to rate matching and de-matching, interleaving and scrambling, demodulation and HARQ buffer management as well as OFDM modulation/demodulation and channel estimation. + +Key features of the FPGA-based accelerator include: + +- 2X10/25G eCPRI or Ethernet open fronthaul interface +- Built-in SyncE/IEEE 1588v2 synchronization + external reference timing +- L1 offloading options + - LDPC encoding and decoding + - Polar encoding and decoding + - HARQ management with on board DDR memory (including DDR controller and interfaces) + - Other L1 offloading candidates include PRACH detection, MIMO encoding and decoding, channel estimation + - Partial or full L1 functions can be offloaded. It is recommended to offload the user-plane channel coding chain and part of or the entire control-plane channel coding chain to the hardware accelerator. +- PCIe Gen3 x16, two Gen4 x8, or PCIe Gen3 x16 bifurcated to two Gen3 x8 +- GPP supported + +- Standard PCIe FHHL card (It is assumed that the hardware accelerators further perform NIC functions). +- 2x SFP28 for 25G Ethernet +- 8GB DDR4 memory for buffering +- Power consumption not to exceed 75W + +The accelerator requirements are summarized in Table 2-5. + +**Table 2-5: Accelerator Hardware Component List** + +| Item Name | Description for FPGA 1 | Description for FPGA 2 | +|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------| +| SoC Resources | System Logic cells - 930K<br>CLB LUT - 425K<br>SDFEC -8<br>DSP Slices - 4,272<br>BRAM - 38.0Mb<br>URAM - 22.5Mb | System Logic cells - 1,143K<br>CLB LUT - 523K<br>CLB Flip-Flops -1,045K<br>DSP Slices - 1,968<br>BRAM - 34.6Mb<br>URAM - 36.0Mb | +| Form Factor | FHHL PCIe Form Factor | | +| PCIe Interface | x8 Gen1, Gen2, Gen3 interface to FPGA 2 and<br>x8 Gen1, Gen2, Gen3 interface to FPGA 1<br>have x16 to two x8 bifurcation | | +| On Board Memory | Total Capacity 4 GB in PL, upgradeable to 8GB<br>Total Capacity 2 GB in PS, upgradeable to 4GB | Total Capacity 4 GB in PL, upgradeable to 8GB<br>Total Capacity 2 GB in PS, upgradeable to 4GB | +| Network Interface(s) | | 2xSFP28 optical interfaces to FPGA2<br>(User Configurable, includes 10/25 Ethernet) | +| Other External Interface(s) | Micro USB for JTAG support (FPGA programming and debug) and access to BMC | | +| Graphical User interface | GUI for monitoring the basic board parameters, monitoring temperature alerts, firmware upgrades for BMC | | +| Board Management Controller | <ul style="list-style-type: none"> <li>• Power sequencing and reset</li> <li>• Field upgrades</li> <li>• FPGA configuration and control</li> <li>• Clock configuration</li> <li>• I2C bus access</li> <li>• USB 2.0</li> </ul> | | +| Operating Temperature | -5°C - 55°C | | +| Power | < 75 W | | + +| | | +|------------------|------------------------------------------------------------------------------------------------------------------------------| +| Clocking Options | Low-Jitter, configurable clock ranging from 10MHz to 750MHz<br>1 PPS input and output with assembly option for OCXO and TCXO | +|------------------|------------------------------------------------------------------------------------------------------------------------------| + +The following are the accelerator's functional and interface requirements. + +###### **Functional offload requirements:** + +One of the candidate functions for offloading is the LDPC encoder and decoder, which typically consists of computationally intensive and relatively highly power consuming functions. It must be noted that neither software implementation in CPU nor soft FPGA logic implementation would provide a highly power efficient solution while meeting/exceeding 3GPP NR user-plane encoder/decoder throughput and latency requirements, rather a hardened implementation of the FEC functions would be very power efficient. Downlink and uplink throughputs of up to 40Gbps and 18Gbps, respectively, are shown feasible with this architecture. Other candidate L1 functions for acceleration include CRC generation, segmentation, bit-level/sub-block interleaving and scrambling as well as FFT/IFFT processing, for which an FPGA can be used. + +For other symbol processing L1 functions which require heavy multiply and accumulation operations, FPGAs 1 and 2 have DSP blocks that can efficiently perform these operations. Polar encoding and/or decoding on the control-plane can also be offloaded to FPGA 1 resulting in high throughputs and low latencies. + +###### **Interface requirements:** + +**PCIe:** PCIe interface is widely used to provide interface between the GPP and hardware accelerators. FPGA devices have dedicated PCIe hard IP which facilitate implementation and quick setup of PCIe interface. They support both PCIe Gen3 x16 or PCIe Gen4 x8, which allow the FPGA device to interface with any GPP supporting either PCIe Gen3 x16 or PCIe Gen4 x8 interface. + +**Fronthaul:** FPGA devices can support various speed grades and any fronthaul protocols, customers can use off-the-shelf eCPRI or Ethernet IPs to quickly implement and configure any fronthaul interface protocol. + +**Serial transceivers:** FPGA devices have SerDes resources to implement various connectivity speeds (e.g., 33 Gb/s) per SerDes, 10G/25G/50G/100G Ethernet connections can use these SerDes resources. + +**Ethernet MAC speed:** FPGA devices have hardened implementations of Ethernet MAC that support speeds of 100 Gbps and above. The Ethernet MAC IP allows power-efficient implementation of high speed Ethernet connectivity. In the example shown in Figure 2-3, FPGA 1 and FPGA 2 can use the hard 100Gbps MAC IPs to connect each other, allowing the L1 and fronthaul functions to be distributed across these two FPGAs with less connectivity overhead. For other Ethernet MACs such as 10G/25G Ethernet, they provide soft Ethernet MAC IPs, so when implementing eCPRI or Ethernet fronthaul functions, 10G/25G Ethernet MAC can be used. + +###### ***b. Accelerator Design*** + +The hardware accelerator supports GPP. Figure 2-5 illustrates a two-chip acceleration architecture comprising two FPGAs with multi-lane PCIe interfaces toward the CPU and external connectivity toward O-RU<sub>7-2</sub>(s) via eCPRI and O-CU(s) through GbE connectivity. The example architecture further depicts multi-lane Gen3 or Gen4 PCIe interfaces between each FPGA and the CPU. The FPGAs communicate through high-bandwidth Ethernet (GbE) transport. + +![Figure 2-5: Example 2-chip FPGA-based Hardware Acceleration in O-DU7-2. The diagram shows an X86 or ARM-based CPU (L2 and Partial L1) connected to two FPGAs. FPGA1 (L1 Offload) and FPGA2 (Connectivity) are connected via an Inter-Chip Interface (100G Ethernet). The CPU is connected to FPGA1 via a [Bifurcated] PCIe Interface (PCIe Gen3x16 (Gen4x8) 100G). The CPU is also connected to FPGA2 via an F1 Interface Ethernet (10/25G). FPGA2 is connected to a Fronthaul Interface (10/25G Ethernet/eCPRI).](ff8a43a251227f166e53a681a24cb87f_img.jpg) + +Figure 2-5: Example 2-chip FPGA-based Hardware Acceleration in O-DU7-2. The diagram shows an X86 or ARM-based CPU (L2 and Partial L1) connected to two FPGAs. FPGA1 (L1 Offload) and FPGA2 (Connectivity) are connected via an Inter-Chip Interface (100G Ethernet). The CPU is connected to FPGA1 via a [Bifurcated] PCIe Interface (PCIe Gen3x16 (Gen4x8) 100G). The CPU is also connected to FPGA2 via an F1 Interface Ethernet (10/25G). FPGA2 is connected to a Fronthaul Interface (10/25G Ethernet/eCPRI). + +**Figure 2-5: Example 2-chip FPGA-based Hardware Acceleration in O-DU<sub>7-2</sub>** + +##### 2.2.3.2.3 Accelerator Design Solution 3 + +Channel coding for LDPC and fronthaul compression requires a significant amount of bit level processing and is well suited to a fine-grained structured ASIC. Features include: + +- Virtualization: Multi-channel DMA, Virtual machine integration, load balancing functions +- Look-aside FEC: Turbo (de)coding, LDPC (de)coding, Rate (De)Matcher, (De) Interleaver, CRC, HARQ retransmission & (de) interleaver. + +###### *a. Accelerator Requirement* + +Accelerator Hardware and Firmware features are listed in Table 2-6 and Table 2-7, respectively. + +**Table 2-6: Accelerator Hardware Feature List** + +| Item Name | Description | +|-----------------------------|-----------------------------------------------------------| +| PCIe | Gen3 x16 | +| Form factor | HHHL | +| DDR | DDR4 (64-bit +ECC), 2667Mbps Interface for HARQ buffering | +| Board Management Controller | Telemetry, Security. | +| Power | <35W | + +**Table 2-7: Accelerator Firmware Feature List** + +| Item Name | Description | +|------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Queuing | 64 Queues supported equally split between UL & DL. | +| LDPC Acceleration | NR LDPC Encoding with, interleaving and rate-matching.<br>NR LDPC Decoding with sub-block de-interleaving function of reverse rate matching.<br>Early Termination, CRC attachment and HARQ buffering.<br>5G Throughput: DL 23Gbps, UL 8Gbps | +| Load Balancing (channel coding) | Load balancer distributes the pending encoder/decoder requests to encoder/decoders | +| Descriptor Format (channel coding) | Code block and transport block based interface.<br>Software enablement by BBDEV API (DPDK)<br><a href="https://www.dpdk.org/">https://www.dpdk.org/</a><br><a href="https://doc.dpdk.org/guides/prog_guide/bbdev.html">https://doc.dpdk.org/guides/prog_guide/bbdev.html</a> | + +###### b. Accelerator Design + +The following diagram shows the structured ASIC based accelerator design. + +![Diagram of Structured ASIC Accelerator Design showing a Digital Processing Unit (L3, L2, L1(part)) connected via PCIe Gen 3x16 or lower (100G) to a Structured ASIC (LDPC Code/Transport Block).](db6bb73c9af7d4b1ee058439d0cb1460_img.jpg) + +``` + +graph LR + DPU["Digital Processing Unit +L3,L2,L1(part)"] + subgraph ASIC ["Structured ASIC"] + LDPC["LDPC Code/Transport Block"] + end + DPU <-->|PCIe Gen 3x16 +Or lower (100G)| LDPC + +``` + +Diagram of Structured ASIC Accelerator Design showing a Digital Processing Unit (L3, L2, L1(part)) connected via PCIe Gen 3x16 or lower (100G) to a Structured ASIC (LDPC Code/Transport Block). + +**Figure 2-6: Structured ASIC Accelerator Design** + +#### 2.2.3.3 Baseboard Management Controller + +BMC is used to perform hardware power control (power on, power off and power cycle), monitor hardware status (temperatures, voltages, etc), monitor Basic I/O System (BIOS)/ Unified Extensible Firmware Interface (UEFI) firmware status, and log system events. It provides remote access via shared or dedicated NIC. System user can do console access via serial or physical/Kernel-based Virtual Machine (KVM). The BMC has dedicated RAM and flash memory. It provides access via serial port or Ethernet port. Figure 2-2 describes the BMC connections with related components. + +### 2.2.4 Synchronization and Timing + +#### 2.2.4.1 Synchronization and Timing Design 1 + +This section describes the synchronization and timing mechanism that is used in the O-DU<sub>7-2</sub>. + +##### a. Hardware Requirements + +The O-DU<sub>7-2</sub> shall support following timing synchronization methods: + +1. GPS Synchronization +2. Ethernet based IEEE1588V2 Synchronization +3. BeiDou Synchronization +4. BeiDou and GPS switching + +##### b. Hardware Design + +Depending on the timing distribution topologies used, the O-DU<sub>7-2</sub> system clock is able to synchronize with the Grand Master Clock (GMC) using IEEE1588 via either the front haul NIC or backhaul NIC, or synchronizing timing using Global Navigation Satellite System (GNSS). In the case of IEEE1588, the Physical Hardware Clock (PHC) within the NIC is synchronized with the GMC first, then the O-DU<sub>7-2</sub> system clock is synchronized with the PHC. The O-DU<sub>7-2</sub> is also capable to provide clock to the O-RU<sub>7-2</sub> via front haul if needed. When GNSS becomes available to O-DU<sub>7-2</sub>, it will be able to synchronize the system clock to Coordinated Universal Time (UTC). Figure 2-7 outlines the O-DU<sub>7-2</sub> timing synchronization mechanisms. + +![Figure 2-7: O-DU7-2 Timing Synchronization diagram. The diagram shows a central 'System Clock' block. To its left is a 'NIC' block containing a 'PHC' (Physical Hardware Clock). A double-headed arrow connects the 'System Clock' to the 'PHC'. Below the 'NIC' block is a 'Backhaul' label with a downward arrow. To the right of the 'System Clock' is another 'NIC' block containing a 'PHC'. A double-headed arrow connects the 'System Clock' to this 'PHC'. Above this 'NIC' block is a 'GNSS' block with a downward arrow labeled '1pps' pointing to the 'PHC'. Below this 'NIC' block is a 'Fronthaul' label with a downward arrow.](3b9f38374684ba091e83d9cdedbc8602_img.jpg) + +Figure 2-7: O-DU7-2 Timing Synchronization diagram. The diagram shows a central 'System Clock' block. To its left is a 'NIC' block containing a 'PHC' (Physical Hardware Clock). A double-headed arrow connects the 'System Clock' to the 'PHC'. Below the 'NIC' block is a 'Backhaul' label with a downward arrow. To the right of the 'System Clock' is another 'NIC' block containing a 'PHC'. A double-headed arrow connects the 'System Clock' to this 'PHC'. Above this 'NIC' block is a 'GNSS' block with a downward arrow labeled '1pps' pointing to the 'PHC'. Below this 'NIC' block is a 'Fronthaul' label with a downward arrow. + +**Figure 2-7: O-DU<sub>7-2</sub> Timing Synchronization** + +#### 2.2.4.2 Synchronization and Timing Design 2 + +This section describes the synchronization and timing mechanism that is used in the hardware accelerator board. + +##### a. Hardware Requirements + +Each hardware accelerator board that supports connectivity functions (e.g., O-RAN fronthaul) in O-DU<sub>7-2</sub> must be able to support external synchronization I/O and to receive or transmit 1 PPS reference clock source in order to ensure synchronization across network. + +##### b. Hardware Design + +The accelerator board can operate in the master or slave mode when supporting IEEE 1588v2 timing/synchronization. It can generate 1 PPS reference clock for synchronization in the master mode and can receive the 1 PPS reference clock in the slave mode for internal synchronization. The timing circuitry of the accelerator board is shown in Figure 2-8. Two FPGA SerDes transceivers are used to receive and transmit SyncE TX and RX clocks. + +![Figure 2-8: HW Acceleration Board Timing and Synchronization diagram. The diagram shows a PLL block receiving three inputs: SyncE RX Clock, TCXO/OCXO Reference, and GPS (1 PPS). The PLL outputs three signals: SyncE TX Clock, 1 PPS, and Other Clocks. These signals are connected to a SerDes FPGA (IEEE 1588v2 Stack) block.](c682f7085f772e9bc7c42e9e1e617ce7_img.jpg) + +``` + +graph LR + SyncERX[SyncE RX Clock] --> PLL[PLL] + TCXO[TCXO/OCXO Reference] --> PLL + GPS[GPS 1 PPS] --> PLL + PLL --> SyncETX[SyncE TX Clock] + PLL --> PPS[1 PPS] + PLL --> Other[Other Clocks] + SyncETX --> SerDesFPGA[SerDes FPGA IEEE 1588v2 Stack] + PPS --> SerDesFPGA + Other --> SerDesFPGA + +``` + +Figure 2-8: HW Acceleration Board Timing and Synchronization diagram. The diagram shows a PLL block receiving three inputs: SyncE RX Clock, TCXO/OCXO Reference, and GPS (1 PPS). The PLL outputs three signals: SyncE TX Clock, 1 PPS, and Other Clocks. These signals are connected to a SerDes FPGA (IEEE 1588v2 Stack) block. + +**Figure 2-8: HW Acceleration Board Timing and Synchronization** + +### 2.2.5 External Interface Ports + +The external interfaces of O-DU<sub>7-2</sub> are described below. + +#### a. Hardware Requirements + +The following table shows the external ports or slots that the system provided. + +**Table 2-8: External Port List** + +| Item Name | Description | +|--------------|-------------------------------------------| +| Ethernet | Octave Gigabit Ethernet LAN connectors | +| | Dual 10GbE Base-T Ethernet connectors | +| | Dual 10GbE SFP+ Faber Ethernet connectors | +| | 2x100G QSFP28 or 2x25G SFP28 | +| USB | 2 USB 3.0 ports | +| Serial Port | 1 COM port via RJ45 | +| Antenna port | 1 SMA connector for GNSS | + +#### b. Hardware Design + +The digital processing unit is a SOC device which provides the external ports described in the hardware requirement section. The system includes 2 USB 3.0 ports, and the serial RS232 port that can be used for Console Redirection, e.g. Out-of-Band Management. The system provides eight 1Gbps and four 10Gbps Ethernet ports. There are two or four 25G eCPRI ports in system depends on the accelerator card used. The system also provides a RF interface to connect GNSS antenna. The following diagram outlines the external interfaces that supported. + +![Figure 2-9: External interfaces reference design. A central box labeled 'O-DU7-2' is connected to four external interface boxes: '2 USB 3.0 Ports' (top left), 'Serial Port' (bottom left), 'GNSS Antenna Port' (top right), and 'Ethernet Ports' (bottom right). Each connection is represented by a double-headed arrow.](79ff17d14f050d51313216ffc5b93745_img.jpg) + +``` + +graph LR + ODU72[O-DU7-2] <--> USB[2 USB 3.0 Ports] + ODU72 <--> Serial[Serial Port] + ODU72 <--> GNSS[GNSS Antenna Port] + ODU72 <--> Ethernet[Ethernet Ports] + +``` + +Figure 2-9: External interfaces reference design. A central box labeled 'O-DU7-2' is connected to four external interface boxes: '2 USB 3.0 Ports' (top left), 'Serial Port' (bottom left), 'GNSS Antenna Port' (top right), and 'Ethernet Ports' (bottom right). Each connection is represented by a double-headed arrow. + +**Figure 2-9: External interfaces reference design** + +### 2.2.6 O-DU<sub>7-2</sub> Firmware + +BIOS and BMC firmware are needed in the system and shall be installed. + +### 2.2.7 Mechanical + +The mechanical design for mother board, chassis, and cooling are listed in this section. + +#### - **Mother Board** + +The mechanical layout of the mother board shows the location of major components and interface ports. The following diagram also provides the dimension of the board. + +![Mother Board Layout Diagram showing a 10x8 inch board with various components. The central SoC is 45x52.5mm. Components include LAN ports (LAN1-8), USB3.0, SATA, M.2 slots, and various connectors.](f51ee5a828b83bb23778bc297d333ff9_img.jpg) + +The diagram illustrates the layout of a 10x8 inch mother board. Key components and their locations are as follows: + +- Top Edge:** LAN1, LAN2, LAN3, LAN4, LAN5, LAN6, LAN7, LAN8 (RJ45); USB3.0 x2; IPMI. +- Right Edge:** SATA; SATA; SoC SMBus; PWR120; USB 2.0; DOOR 2667MHz; TPM module; HDD PWR; Spin 2V; ATX 24 pin. +- Bottom Edge:** Fan1; Fan2; Fan3; SATA; SATA; Fan4; Fan5; Front Panel. +- Left Edge:** VGA; COM; VGA; COM; Pny 10GbE CS4227; 12 B-key; LAN LEDs/GPIO; USB Type-A. +- Internal Components:** 10GbE BaseT x2; 10GbE x2 SFP+; NIC; BMC; 45x52.5mm (SoC); 12 B-key; 12 B-key. + +Mother Board Layout Diagram showing a 10x8 inch board with various components. The central SoC is 45x52.5mm. Components include LAN ports (LAN1-8), USB3.0, SATA, M.2 slots, and various connectors. + +**Figure 2-10: Mother Board Layout Diagram** + +- Chassis +- The 1U rack mount chassis contains the layout of the power supply, Solid State Drive (SSD) and fans. The chassis dimension is showed in following figure. + +![Figure 2-11: Chassis Mechanical Diagram. A 3D perspective view of a server chassis. The chassis is rectangular with a front panel and a rear panel. The front panel has a handle and a latch. The rear panel has a fan tray and a power supply unit. The dimensions are: 437 mm (width), 381 mm (depth), and 43 mm (height). The fan tray is labeled 'Installed Fans' and 'Optional Fans'. The power supply unit is labeled 'Power Supply'. The SSD is labeled 'SSD'.](2f0f792fe51c6ebd4748f90cfa385b9e_img.jpg) + +Figure 2-11: Chassis Mechanical Diagram. A 3D perspective view of a server chassis. The chassis is rectangular with a front panel and a rear panel. The front panel has a handle and a latch. The rear panel has a fan tray and a power supply unit. The dimensions are: 437 mm (width), 381 mm (depth), and 43 mm (height). The fan tray is labeled 'Installed Fans' and 'Optional Fans'. The power supply unit is labeled 'Power Supply'. The SSD is labeled 'SSD'. + +**Figure 2-11: Chassis Mechanical Diagram** + +#### c. Cooling + +The system installs 4x 40x28mm PWM fans for the cooling. Up to 6 fans can be installed if needed. + +### 2.2.8 Power Unit + +In a fully loaded system with two PCIe slots populated with 75W each, the system power consumption should be less than 400W. The total system power requirement shall be kept less than 80% of the power supply capacity. + +#### a. Hardware Requirements + +The power is provided by 500W High-Efficiency power supply with Power Management Bus (PMBus) 1.2. + +The power support input and output power rails are listed below. + +AC Input: 100-240V, 50-60Hz, 6.6A max + +DC Output: +3.3V: 12A + ++5V: 15A + ++5V standby: 3A + ++12V: 41A + +-12V: 0.2A + +#### b. Hardware Requirements + +The O-DU<sub>7.2</sub> chassis includes one 500W power supply unit. The power supply unit is auto-switching capable, which enables it to automatically sense and operate at a 100v to 240v input voltage. The power supply unit features are listed in the following table. + +**Table 2-9: Power supply unit feature list** + +| Item Name | Description | +|-----------------------------|----------------------------------------------------------------| +| Output connectors | 24pin/8pin/4+4pin/HDD/I2C | +| Dimension (W x D x H) | 3.9 x 7.1 x 1.6 inch | +| Maximum Output Power | +3.3V: 12A<br>+5V: 15A<br>+12V: 41A<br>-12V: 0.2A<br>+5Vsb: 3A | +| Rated Input Voltage/Current | 100-240Vac / 6.6A max | +| Rated Input Frequency | 50-60HZ | +| Inrush current | Less than 30A | + +### 2.2.9 Thermal + +Active cooling with up to 6 fans is integrated in the chassis. + +The hardware acceleration cards described in Section 2.2.2.2 use passive cooling and a custom heatsink and is equipped with temperature sensors. It is designed to operate in temperatures ranging from -5°C to +55°C. + +### 2.2.10 Environmental and Regulations + +The O-DU<sub>7.2</sub> hardware system is RoHS Compliant. The power supply unit is EMC FCC/CISPR Class B compliant. + +Table 2-10 lists the environmental related features and parameters. + +**Table 2-10: Environmental Features** + +| Item Name | Description | +|---------------------------------|----------------------------| +| Operating Temperature | -5°C to +55°C | +| Non-operating Temperature | -40°C to 70°C | +| Operating Relative Humidity | 8% to 90% (non-condensing) | +| Non-operating Relative Humidity | 5% to 95% (non-condensing) | + +The hardware accelerator described in Section 2.2.2.2 is designed to operate in indoor environments and in temperatures ranging from -5°C to +55°C. + + + +## 2.3 O-RU<sub>7-2</sub> Hardware Reference Design + +In this section we describe, the HW reference design of all O-RU<sub>7-2</sub> components including block diagram, HW components, synchronization and timing, mechanical design, power supply, thermal, and environment requirements. + +### 2.3.1 O-RU<sub>7-2</sub> High-Level Functional Block Diagram + +Figure 2-12 provides a high-level functional block diagram depicting the major HW/SW components. It also highlights the internal/external interfaces that are required. This document shows how to implement the system defined by the IPC-HAR [6] document. + +![Figure 2-12: High-Level Functional Block Diagram of O-RU7-2. The diagram shows the internal components of the O-RU7-2 unit. A dashed box labeled 'O-RU7-2' encloses the eCPRI, Digital Processing Unit, RF Processing Unit, Timing Unit, and Power Unit. The eCPRI block has a bidirectional connection to 'To/From O-DU7-2' via an 'O-RAN FH' interface. The eCPRI, Digital Processing Unit, and RF Processing Unit are connected in a chain with bidirectional arrows. The Timing Unit receives 'Local timing from CDR' and 'Local timing from GNSS or equivalent' (via an optional GNSS antenna). The Timing Unit provides timing to the eCPRI, Digital Processing Unit, and RF Processing Unit. The Power Unit provides power to the Timing Unit, Digital Processing Unit, and RF Processing Unit.](f14905a438a9ec0ce711db0a20e8dc49_img.jpg) + +``` + +graph LR + subgraph O-RU7-2 + eCPRI[eCPRI] <--> DPU[Digital Processing Unit] + DPU <--> RPU[RF Processing Unit] + TU[Timing Unit] + PU[Power Unit] + eCPRI --> TU + DPU --> TU + RPU --> TU + PU --> TU + PU --> DPU + PU --> RPU + end + eCPRI <-->|O-RAN FH| ToFrom[To/From O-DU7-2] + GNSS[GNSS optional] -->|Local timing from GNSS or equivalent| TU + CDR[CDR] -->|Local timing from CDR| TU + +``` + +Figure 2-12: High-Level Functional Block Diagram of O-RU7-2. The diagram shows the internal components of the O-RU7-2 unit. A dashed box labeled 'O-RU7-2' encloses the eCPRI, Digital Processing Unit, RF Processing Unit, Timing Unit, and Power Unit. The eCPRI block has a bidirectional connection to 'To/From O-DU7-2' via an 'O-RAN FH' interface. The eCPRI, Digital Processing Unit, and RF Processing Unit are connected in a chain with bidirectional arrows. The Timing Unit receives 'Local timing from CDR' and 'Local timing from GNSS or equivalent' (via an optional GNSS antenna). The Timing Unit provides timing to the eCPRI, Digital Processing Unit, and RF Processing Unit. The Power Unit provides power to the Timing Unit, Digital Processing Unit, and RF Processing Unit. + +Figure 2-12: High-Level Functional Block Diagram + +### 2.3.2 O-RU<sub>7-2</sub> Hardware Components + +General block diagrams for 2T2R and 4T4R O-RU<sub>7-2</sub> examples are shown subsequently. + +**Error! Reference source not found.** shows a 2T2R implementation and **Error! Reference source not found.** shows a 4T4R implementation. In each of these diagrams, the Digital Processing Unit is further detailed in **Error! Reference source not found.** Items under the umbrella of RF Processing Unit, including the Transceiver, RFFE and other RF items are reviewed in additional detail in **Error! Reference source not found.** Clock and Synchronization + +are reviewed in **Error! Reference source not found..** The Power Unit is detailed in **Error! Reference source not found..** + +![Figure 2-13: 2T2R General Block Diagram with TR switch. This block diagram illustrates the architecture of a 2T2R (2 Transmit, 2 Receive) system. On the left, a 'Digital Processing Unit' (DPU) is connected to a 'Clock' and a 'Synchronizer'. The DPU has control lines for 'TR control', 'Tx enable', and 'Rx enable'. It is connected to a 'Transceiver' block via 'SERDES' and 'SPI' interfaces. The 'Transceiver' is connected to a 'Power Unit'. The 'Transceiver' outputs are connected to 'Port A' through a series of components including 'bypass', 'RFFE', 'PA', and 'enable' blocks. The 'Power Unit' provides power to the 'Transceiver' and the 'Port A' components.](ee465fd7e617a0833acdd69e83e266ff_img.jpg) + +Figure 2-13: 2T2R General Block Diagram with TR switch. This block diagram illustrates the architecture of a 2T2R (2 Transmit, 2 Receive) system. On the left, a 'Digital Processing Unit' (DPU) is connected to a 'Clock' and a 'Synchronizer'. The DPU has control lines for 'TR control', 'Tx enable', and 'Rx enable'. It is connected to a 'Transceiver' block via 'SERDES' and 'SPI' interfaces. The 'Transceiver' is connected to a 'Power Unit'. The 'Transceiver' outputs are connected to 'Port A' through a series of components including 'bypass', 'RFFE', 'PA', and 'enable' blocks. The 'Power Unit' provides power to the 'Transceiver' and the 'Port A' components. + +Figure 2-13: 2T2R General Block Diagram with TR switch + +![Figure 2-14: 4T4R General Block Diagram with TR switch. This block diagram illustrates the architecture of a 4T4R (4 Transmit, 4 Receive) system. It follows a similar structure to Figure 2-13, with a 'Digital Processing Unit' (DPU) connected to a 'Clock' and a 'Synchronizer'. The DPU has control lines for 'TR control', 'Tx enable', and 'Rx enable'. It is connected to a 'Transceiver' block via 'SERDES' and 'SPI' interfaces. The 'Transceiver' is connected to a 'Power Unit'. The 'Transceiver' outputs are connected to 'Port A' through a series of components including 'bypass', 'RFFE', 'PA', and 'enable' blocks. The 'Power Unit' provides power to the 'Transceiver' and the 'Port A' components.](eda08cbd318993c87bf3f3dc326243e7_img.jpg) + +Figure 2-14: 4T4R General Block Diagram with TR switch. This block diagram illustrates the architecture of a 4T4R (4 Transmit, 4 Receive) system. It follows a similar structure to Figure 2-13, with a 'Digital Processing Unit' (DPU) connected to a 'Clock' and a 'Synchronizer'. The DPU has control lines for 'TR control', 'Tx enable', and 'Rx enable'. It is connected to a 'Transceiver' block via 'SERDES' and 'SPI' interfaces. The 'Transceiver' is connected to a 'Power Unit'. The 'Transceiver' outputs are connected to 'Port A' through a series of components including 'bypass', 'RFFE', 'PA', and 'enable' blocks. The 'Power Unit' provides power to the 'Transceiver' and the 'Port A' components. + +Figure 2-14: 4T4R General Block Diagram with TR switch + +In following section, we describe their functionality, interfaces and performance of every block in the RF Processing Unit. Since device integration is an ongoing activity, chip boundaries may be fluid and some functionalities may move from one block to another or entire functionalities may be absorbed into other blocks. The sections below describe the functional blocks independent of which physical device they may reside in. + +#### 2.3.2.1 Digital Processing Unit + +The digital processing unit of O-RU<sub>7-2</sub> is mainly for performing tasks related to FH interface, lower L1, RF interface, and OAM. + +##### i. FPGA Solution Design 1 + +The digital processing unit of O-RU<sub>7-2</sub> is mainly for performing FH interface, lower L1, RF interface, and OAM functions. + +##### a. FPGA Requirement + +The following items are the main requirement for the O-RU<sub>7-2</sub>: + +- Interface requirement: One lane of bi-direction Serdes targeting eCPRI will be @10Gbps for FH split option 7-2. Four lanes of bi-direction JESD204B Serdes will be used for 2T2R. Eight lanes of bi-direction JESD204B Serdes will be used for 4T4R +- Resource requirement: FPGA resource requirements for 2T2R and 4T4R are shown in Table 2-11 and Table 2-12. + +**Table 2-11: Resource requirement for 2T2R O-RU<sub>7-2</sub>** + +| Module | FF | LUT | BRAM18 | DSP | +|------------------|--------|--------|--------|-----| +| Model A | 343800 | 171900 | 1000 | 900 | +| IFFT & CP+ | 7763 | 5323 | 27 | 23 | +| IFFT & CP- | 7763 | 5323 | 27 | 23 | +| PRACH frontend | 4000 | 3000 | 32 | 50 | +| DUC | 4820 | 4346 | 0 | 108 | +| DDC | 4820 | 4346 | 0 | 108 | +| CFR | 11470 | 6136 | 22 | 36 | +| DPD | 34269 | 13250 | 188 | 87 | +| JESD204B | 4314 | 4285 | 0 | 0 | +| Fronthaul(eCPRI) | 10000 | 8000 | 1 | 0 | +| Other | 8000 | 5000 | 100 | 12 | +| Total | 97219 | 59009 | 397 | 447 | + +**Table 2-12: Resource requirement for 4T4R O-RU<sub>7-2</sub>** + +| Module | FF | LUT | DSP | BRAM18 | +|-----------------------|--------|--------|-----|--------| +| Resource Mapping | 10000 | 8000 | 0 | 102 | +| PreCoding & pilot Ins | 5000 | 4000 | 16 | 4 | +| IFFT+CP | 6466 | 3952 | 15 | 75 | +| Resource De-Mapping | 10000 | 8000 | 0 | 181 | +| FFT+CP | 6466 | 3952 | 15 | 75 | +| PRACH Filtering | 8000 | 6000 | 36 | 16 | +| Sub-Total | 45932 | 33904 | 82 | 453 | +| ChFIR | 2832 | 2686 | 84 | 0 | +| DUC | 5148 | 3756 | 36 | 0 | +| CFR | 25676 | 12372 | 96 | 48 | +| DPD | 45770 | 17643 | 105 | 217 | +| AGC | 1000 | 600 | 8 | 4 | +| DDC | 1716 | 1252 | 12 | 0 | +| UL_ChFIR | 2832 | 2686 | 84 | 0 | +| JESD2048 | 9900 | 11127 | 0 | 0 | +| eCPRI | 15000 | 14000 | 0 | 50 | +| total | 155806 | 100026 | 507 | 772 | + +- Processor requirement: For device model A, the processor will be used, one is used for device control and management plane functions, the other one is for Digital Pre-Distortion (DPD) feedback path. For device model C, dual-core ARM cortex-A53 will be used, similarly one is used for device control and management plane functions, the other one is for DPD feedback path. +- Power requirement: Power estimations for 2T2R and 4T4R are shown in Figure 2-15 and Figure 2-16. + +![Summary of On-Chip Power and Power Supply](5e486c02860fecf99ec2a0ff66f3fe71_img.jpg) + +The figure displays a summary of on-chip power and power supply requirements. The 'Summary' section shows a total on-chip power of 8.536 W, a junction temperature of 100.0 °C, and a thermal margin of 0.0 °C. The 'On-Chip Power' table lists power consumption for various resources, and the 'Power Supply' table lists voltage and current requirements for different power sources. + +| Summary | | | | | +|----------------------|----------|-----|---------------------------------------|--------| +| Total On-Chip Power | 8.536 W | 11% | Transceiver | 0.898W | +| Junction Temperature | 100.0 °C | 0% | I/O | 0.000W | +| Thermal Margin | 0.0 °C | 68% | PS+FFPGA Dyn. | 5.848W | +| Effective ΘJA | 3.7 °C/W | 23% | Device Static | 1.990W | +| | | | Power supplied to off-chip devices... | 0.000W | + +| On-Chip Power | | | +|---------------|-----------|-----| +| Resource | Power (W) | (%) | +| CLOCK | 0.923 | 11 | +| LOGIC | 2.305 | 27 | +| BRAM | 1.518 | 18 | +| DSP | 0.902 | 11 | +| Core Dynamic | 0.000 | 0 | + +| Power Supply | | | +|-----------------------|---------|-----------| +| Source | Voltage | Total (A) | +| V <sub>CCINT</sub> | 1.000 | 6.753 | +| V <sub>CCBRAM</sub> | 1.000 | 0.175 | +| V <sub>CCALX</sub> | 1.800 | 0.127 | +| V <sub>CCALX_IO</sub> | 2.000 | | +| V <sub>CCO</sub> 3.3V | 3.300 | | +| V <sub>CC</sub> 2.5V | 2.500 | | + +Summary of On-Chip Power and Power Supply + +Figure 2-15: Power estimation for 2T2R O-RU<sub>7-2</sub> +![Figure 2-15: Power estimation for 2T2R O-RU7-2. The image shows a power estimation summary and detailed breakdown. The summary table highlights Total On-Chip Power at 9.2 W, Junction Temperature at 100.0 °C, Thermal Margin at 0.0 °C, and Effective OJA at 1.0 °C/W. A detailed breakdown shows power supplied to off-chip devices at 0.000 W. Below the summary are two tables: 'On-Chip Power' and 'Power Supply'.](ddb1b67b648cc0c00188b84af42b23cc_img.jpg) + +| Summary | | | | +|----------------------|----------|-------|--| +| Total On-Chip Power | 9.2 W | | | +| Junction Temperature | 100.0 °C | | | +| Thermal Margin | 0.0 °C | 0.0 W | | +| Effective OJA | 1.0 °C/W | | | + +| Power supplied to off-chip devices... | | | | +|---------------------------------------|---------------------------------------|--------|--| +| 18% | Transceiver | 1.657W | | +| 0% | IO | 0.000W | | +| 56% | PS+FPGA Dyn. | 5.147W | | +| 26% | Device Static | 2.363W | | +| | Power supplied to off-chip devices... | 0.000W | | + +| On-Chip Power | | | +|---------------|-----------|-----| +| Resource | Power (W) | (%) | +| CLOCK | 0.621 | 7 | +| LOGIC | 2.599 | 28 | +| BRAM | 0.542 | 6 | +| DSP | 1.376 | 15 | + +| Power Supply | | | +|-----------------------|---------|-----------| +| Source | Voltage | Total (A) | +| V <sub>CCINT</sub> | 0.720 | 9.511 | +| V <sub>CCINT_ID</sub> | 0.850 | 0.072 | +| V <sub>CCBRAM</sub> | 0.850 | 0.138 | +| V <sub>CCAUX</sub> | 1.800 | 0.284 | +| V <sub>CCAUX_ID</sub> | 1.800 | 0.033 | + +Figure 2-15: Power estimation for 2T2R O-RU7-2. The image shows a power estimation summary and detailed breakdown. The summary table highlights Total On-Chip Power at 9.2 W, Junction Temperature at 100.0 °C, Thermal Margin at 0.0 °C, and Effective OJA at 1.0 °C/W. A detailed breakdown shows power supplied to off-chip devices at 0.000 W. Below the summary are two tables: 'On-Chip Power' and 'Power Supply'. + +Figure 2-16: Power estimation for 4T4R O-RU<sub>7-2</sub> + +- Speed grade, environmental requirement: -2L, 0°C to 110°C + +##### b. FPGA Design + +This solution of the digital processing unit incorporates FPGA and a processor. The FPGA handles high speed digital processing such as low L1, FH, DDC, DUC, CFR and so on. All functions are listed in the previous section. The processor is used for hardware device configuration and the OAM function. The FPGA and the processor core can be integrated into one SOC or implemented into two devices. Here the FPGA and the processor core are integrated into one SOC device. + +![Figure 2-17: FPGA Reference Design Diagram. The diagram shows a central block labeled 'Processor' and 'FPGA'. To the left, 'DDR' is connected via 'MIG', 'Flash' via 'SPI', and 'Debug' via 'MI'. To the right, 'Transceiver' is connected via 'JESD204B', 'PLL' is connected via 'SPI' and provides clock signals of 245.76MHz, 1.92MHz, and 156.25MHz. 'SFP+' is connected via 'IIC' and '10G Serdes'. A power supply block at the bottom lists: Power: 3.3V 2.5V 1.8V 1.35V 1.2V 0.9V.](e755e3e2c4afe67194b013a72c33c094_img.jpg) + +Figure 2-17: FPGA Reference Design Diagram. The diagram shows a central block labeled 'Processor' and 'FPGA'. To the left, 'DDR' is connected via 'MIG', 'Flash' via 'SPI', and 'Debug' via 'MI'. To the right, 'Transceiver' is connected via 'JESD204B', 'PLL' is connected via 'SPI' and provides clock signals of 245.76MHz, 1.92MHz, and 156.25MHz. 'SFP+' is connected via 'IIC' and '10G Serdes'. A power supply block at the bottom lists: Power: 3.3V 2.5V 1.8V 1.35V 1.2V 0.9V. + +Figure 2-17: FPGA Reference Design Diagram + +For the processor portion, the internal RAM resource may not be enough. So the external DDR is needed to let the processor handle more RAM consuming functions such as operation system or stack protocols like Network Configuration Protocol (NetConf) Client. For the O-RU<sub>7-2</sub> design, the DDR3 with 256Mb\*16bit + +memory capacity is enough. The interface between the DDR and processor can be memory interface generator (MIG). The external Flash is used to store operation system related files, calibration information of the RF portion, NetConf related files, FPGA firmware and so on. For this O-RU<sub>7-2</sub> design, the flash with 2Gb memory capacity is enough. The online debug function is performed by external Ethernet PHY with an RJ45 connector. This allows the administrator to visit the internal function of the O-RU<sub>7-2</sub> and control it. The interface between the DDR and processor can be Media-Independent interface (MII). The Ethernet PHY device can be very general 100M Ethernet Transceiver. The FPGA has one serdes lane connected to optical module to perform the fronthaul link between O-RU<sub>7-2</sub> and O-DU<sub>7-2</sub> /FHM<sub>7-2</sub>. Another 4 serdes lanes of the FPGA are needed to connect one transceiver of the O-RU<sub>7-2</sub> to transmit or receive IQ sample by the interface of JESD204B while the FPGA needs synchronized clock signals to work well. The interface between PLL and FPGA should be Low-Voltage Differential Signaling (LVDS). + +#### 2.3.2.2 RF Processing Unit + +For the RF processing unit of O-RU<sub>7-2</sub>, it will perform functionalities of ADC, DAC, LO, down converter, up converter and etc. + +##### 2.3.2.2.1 Transceiver Reference Design + +For the O-RU<sub>7-2</sub> the sampling function and frequency conversion function can be performed by transceiver. The purpose of using the transceiver is to saving power and size of the PCB. The Transceiver is to convert between high speed baseband data and a low-level RF for both transmit and receive signal chain. In addition, the transceiver is responsible for orchestration of control signals not limited to the PA enable, LNA enable, LNA bypass as well as other required system level signals. + +###### a. Hardware Requirements + +Include the requirements for this component. + +- Interface Requirements: The interface requirements for the Transceivers are list in Table 2-13. + +**Table 2-13: Interface requirements of the Transceiver** + +| Item Name | Description | +|--------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| High Speed Data | High speed data represents the baseband information being transmitted or received. Depending on the configuration of the ORAN device, various bandwidths may be supported leading to a range of payload rates. Options for data include parallel data paths, JESD204B and JESD204C. Up to 8 lanes in each direction may be supported although fewer is preferred. Options such as DPD and numeric precision will impact the payload rate. Several options are shown in the following table. All data represents IQ 16-bit (N=16) precision. Some devices support IQ 12 bit (N'=12) which may reduce the required data rates accordingly. The tables below assume 1 ORx for 2 TRx. From Table 2-14 and Table 2-15, the number of lanes required may be determined by dividing the total bit rates shown by the capacity of a lane, typically 12.5 GBPS for JESD204B and 25 GBPS for JESD204C. | +| Reference Clock (Device Clock) | The transceiver should receive a reference for internal clock and LO synthesis needs. This reference clock can function as the JESD204 Device Clock where the interface is by SERDES. The specific clock frequency is determined by the operation mode of the | + +| | | +|------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | transceiver and may range from 1Hz upward. | +| SYSREF | If the transceiver supports SERDES, then it should accept a SYSREF signal from the clock or data source as appropriate. The number and configuration for the SYSREF is dependent on the operating mode of the transceiver. | +| SYNCB | If the transceiver supports SERDES, then it should also support a SYNCB for each link as appropriate. | +| Control | Control of the transceiver is by way of 3 or 4 wire SPI or IIC functioning as a slave. Support for 1.8V control is required and tolerance of 3.3V is preferred. The transceiver may optionally include a separate SPI master for control of peripheral devices as required. | +| GPIO | The transceiver may optionally include GPIO for controlling peripherals including but not limited to PAs, LNAs and other devices. These GPIOs should at a minimum support 1.8V outputs but the specifics will be determined by the connected devices. The GPIO should also support input from peripheral devices. Input should at a minimum support 1.8V logic with tolerance of 3.3V preferred. | +| Tx Enable | The transceiver should provide an output to support enabling and disabling the external devices in the transmit chain such as a TxVGA (optional) and PA. | +| Rx Enable | The transceiver should provide an output to support enabling and disabling the external devices in the transmit chain such as a RF Front End Module or LNA. | +| LNA Bypass | The transceiver should provide an output to support bypassing the LNA appropriately in the condition of a large blocker if so required. | +| RF Outputs | RF outputs including the main Tx signal should support 50 ohm or 100 ohms signalling. These outputs can be either single ended or differential. | +| RF Inputs | RF inputs including the main Rx and the Observation Rx (ORx) (for DPD) should support 50 ohm or 100 ohms signalling. These inputs can be either single ended or differential. The device should support at least 1 ORx. | + +**Table 2-14: Payload with DPD in Digital Device (GBPS Rx/Tx)** + +| Bandwidth (MHz) | Parallel | JESD204B | JESD204C | Parallel | JESD204B | JESD204C | +|-----------------|------------|-------------|-------------|-------------|-------------|-------------| +| | 2T2R | | | 4T4R | | | +| <b>20</b> | 2.95/5.9 | 3.69/7.37 | 3.04/6.08 | 5.9/11.8 | 7.37/14.75 | 6.08/12.17 | +| <b>50</b> | 5.9/11.8 | 7.37/14.75 | 6.08/12.17 | 11.8/23.59 | 14.75/29.49 | 12.17/24.33 | +| <b>100</b> | 11.8/23.59 | 14.75/29.49 | 12.17/24.33 | 23.59/47.19 | 29.49/58.98 | 24.33/48.66 | + +**Table 2-15: Payload with DPD in Transceiver (GBPS Rx/Tx)** + +| Bandwidth (MHz) | Parallel | JESD204B | JESD204C | Parallel | JESD204B | JESD204C | +|-----------------|----------|----------|----------|----------|----------|----------| +|-----------------|----------|----------|----------|----------|----------|----------| + +| | 2T2R | | | 4T4R | | | +|------------|-----------|-----------|-----------|-------------|-------------|-------------| +| <b>20</b> | 1.97/1.97 | 2.46/2.46 | 2.03/2.03 | 3.93/3.93 | 4.92/4.92 | 4.06/4.06 | +| <b>50</b> | 3.93/3.93 | 4.92/4.92 | 4.06/4.06 | 7.86/7.86 | 9.83/9.83 | 8.11/8.11 | +| <b>100</b> | 7.86/7.86 | 9.83/9.83 | 8.11/8.11 | 15.73/15.73 | 19.66/19.66 | 16.22/16.22 | + +- Algorithm Requirements: The transceiver is required to provide appropriate algorithms to sustain RF operation including but not limited to Rx AGC, Tx Power control. DPD and CFR may be included either in the transceiver or in the digital baseband device making the trade-offs in Payload shown in Table 2-11 and Table 2-12. +- Device Configuration: The transceiver should support either 2T2R or 4T4R. In addition, at least one ORx path should be supported. Additional ORx paths are allowed as required for the application. +- Power Dissipation: Total dissipation of the TRx should be less than 6W for 4T4R. +- RF Specifications are given in Table 2-16. + +**Table 2-16: RF specifications in Transceiver** + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Conditions/Comments | +|--------------------------------------------------|--------|-----|--------|------|--------|--------------------------------------------------------------------------------------------------------------| +| TRANSMITTERS | | | | | | | +| Center Frequency | | 650 | | 6000 | MHz | | +| Transmitter Synthesis Bandwidth | | | | 450 | MHz | | +| Transmitter Large Signal Bandwidth | | | | 200 | MHz | | +| Transmitter Attenuation Power Control Range | | 0 | | 32 | dB | Signal-to-noise ratio (SNR) maintained for attenuation between 0 dB and 20 dB | +| Transmitter Attenuation Power Control Resolution | | | 0.05 | | dB | | +| Adjacent Channel Leakage Ratio (ACLR) | | | -66 | | dB | 20 MHz LTE at -12 dBFS | +| In Band Noise Floor | | | | | | 0 dB attenuation; in band noise falls 1 dB for each dB of attenuation for attenuation between 0 dB and 20 dB | +| Out of Band Noise Floor | | | -154.5 | | dBm/Hz | 600 MHz < f ≤ 3000 MHz | +| Maximum Output Power | | | -153 | | dBm/Hz | 0 dB attenuation; 3 × bandwidth/2 offset | +| Third Order Output Intermodulation | OIP3 | | 6 | | dBm | 0 dBFS, continuous wave tone into 50 Ω load, 0 dB transmitter attenuation | + +Image: O-RAN Alliance Logo + +ORAN-WG7.IPC-HRD-Opt7-2.0-v03.00 + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Conditions/Comments | +|--------------------------------------------------------------------------------------------------------------------|-------------------|-----|--------------------------|------|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------| +| Intercept Point | | | 27 | | dBm | 600 MHz < f ≤ 5700 MHz | +| Error Vector Magnitude<br>(Third Generation Partnership Project (3GPP) Test Signals)<br>1900 MHz LO<br>3800 MHz LO | EVM | | 0.6<br>0.53 | | %<br>% | 50 kHz RF PLL loop bandwidth<br>3000 kHz RF PLL loop bandwidth | +| OBSERVATION RECEIVER | ORx | | | | | | +| Center Frequency | | 450 | | 6000 | MHz | | +| Gain Range | | | 30 | | dB | IIP3 improves decibel for decibel for the first 18 dB of gain attenuation; QEC performance optimized for 0 dB to 6 dB of attenuation only | +| Analog Gain Step | | | 0.5 | | dB | For attenuator steps from 0 dB to 6 dB | +| Receiver Bandwidth | | | | 450 | MHz | | +| Maximum Useable Input Level | P <sub>HIGH</sub> | | -11 | | dBm | 0 dB attenuation; increases decibel for decibel with attenuation; continuous wave corresponds to -1 dBFS at ADC<br>75 MHz < f ≤ 3000 MHz | +| Integrated Noise | | | -58.5<br>-57.5 | | dBFS<br>dBFS | 450 MHz integration bandwidth<br>491.52 MHz integration bandwidth | +| Third-Order Input Intermodulation Intercept Point<br>Narrow Band<br><br>1900 MHz<br><br>2600 MHz<br><br>3800 MHz | IIP3 | | 15<br><br>16.5<br><br>18 | | dBm<br><br>dBm<br><br>dBm | Maximum observation receiver gain; test condition: P <sub>High</sub> - 11 dB/tone | +| Wide Band<br><br>1900 MHz<br>2600 MHz<br>38000 MHz | | | 13<br>11<br>13 | | dBm<br>dBm<br>dBm | IM3 products>130 MHz at baseband; test condition: P <sub>High</sub> - 11 dB/tone ; 491.52 MSPS | +| Third-Order Intermodulation Product | IM3 | | -70 | | dBc | 600 MHz < f ≤ 3000 MHz | + +Copyright © 2021 O-RAN ALLIANCE e.V. + Your use is subject to the terms of the O-RAN Adopter License Agreement in Annex ZZZ + +40 + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Conditions/Comments | +|------------------------------------------|-------------------|-----|-----|------|------|-----------------------------------------------------------------------------------------| +| Spurious-Free Dynamic Range | SFDR | | 64 | | dB | Non IMx related spurs, does not include HDx; ( $P_{\text{HIGH}} - 11$ ) dB input signal | +| Harmonic Distortion | HD2 | | | | | ( $P_{\text{HIGH}} - 11$ ) dB input signal | +| Second Order Harmonic Distortion Product | | | -80 | | dBc | In band HD falls within $\pm 100$ MHz | +| | | | -73 | | dBc | Out of band HD falls within $\pm 225$ MHz | +| Third-Order Harmonic Distortion Product | HD3 | | | | | In band HD falls within $\pm 100$ MHz | +| | | | -70 | | dBc | Out of band HD falls within $\pm 225$ MHz | +| | | | -65 | | dBc | | +| RECEIVERS | | | | | | | +| Center Frequency | | | | 6000 | MHz | | +| Gain Range | | | 30 | | dB | | +| Analog Gain Step | | | 0.5 | | dB | Attenuator steps from 0 dB to 6 dB | +| | | | 1 | | dB | Attenuator steps from 6 dB to 30 dB | +| Receiver Bandwidth | $P_{\text{HIGH}}$ | | | 200 | MHz | | +| Maximum Useable Input Level | | | | | | 0 dB attenuation, increases decibel | +| | | | | | | for decibel with attenuation; continuous wave = 1800 MHz; corresponds to -1 dBFS at ADC | +| | | | -11 | | dBm | 75 MHz < f ≤ 3000 MHz | +| Noise Figure | NF | | | | | 0 dB attenuation, at receiver port | +| | | | 12 | | dB | 600 MHz < f ≤ 3000 MHz | +| Input Third-Order Intercept Point | IIP3 | | | | | | +| Difference Product, 2600 MHz (Wideband) | IIP3, d | | 17 | | dBm | Two ( $P_{\text{HIGH}} - 9$ ) dB tones near band edge | +| 2600 MHz (Midband) | | | 21 | | dBm | | +| Sum Product, 2600 MHz (Wideband_ | IIP3, s | | 20 | | dBm | Two ( $P_{\text{HIGH}} - 9$ ) dB tones, at bandwidth/6 offset from the LO | +| HD3 | HD3 | | | | | ( $P_{\text{HIGH}} - 6$ ) dB continuous wave tone at bandwidth/6 offset from the LO | +| | | | -66 | | dBc | 600 MHz < f ≤ 4800 MHz | + +###### b. Hardware Design + +For the O-RU<sub>7-2</sub> the sampling function and frequency conversion function can be performed by transceiver. Usually the transceiver is integrated by ADC, DAC, LO, down converter, up converter and so on. The block diagram of transceiver design is shown in Figure 2-18. + +![Figure 2-18: Transceiver Reference Design Diagram. This block diagram illustrates the internal architecture of a transceiver. On the left, external inputs include REF Clock In, SYSREF, Ext LO/Clock In, Rx1 through Rx4, Tx1 through Tx4, and ORx1 through ORx4. The core consists of a 'Clock, Synchronization & Synthesis' block, four 'Receiver Block' units (1-4), four 'Transmit Block' units (1-4), and an 'Observation Receiver'. Each block contains an ADC or DAC, a multiplier, and a filter. To the right, a 'Control Interface' block manages the system, connected to an 'SPI Port' and a 'JESD204B/C Serial Interface'. The SPI Port handles SCLK, CSB, SDO, and SDIO signals. The Control Interface manages CPIO1, GPIO2, GPIO3, and GPIO#. The JESD204B/C interface handles SYNCIN, SERDES Out, SERDES In, and SYNC OUT signals. A 'DPD Engine' is also shown. Optional features are highlighted in grey, including the Observation Receiver, the DPD Engine, and the JESD204B/C Serial Interface.](f0f7785d9296fdba3169212350218846_img.jpg) + +Figure 2-18: Transceiver Reference Design Diagram. This block diagram illustrates the internal architecture of a transceiver. On the left, external inputs include REF Clock In, SYSREF, Ext LO/Clock In, Rx1 through Rx4, Tx1 through Tx4, and ORx1 through ORx4. The core consists of a 'Clock, Synchronization & Synthesis' block, four 'Receiver Block' units (1-4), four 'Transmit Block' units (1-4), and an 'Observation Receiver'. Each block contains an ADC or DAC, a multiplier, and a filter. To the right, a 'Control Interface' block manages the system, connected to an 'SPI Port' and a 'JESD204B/C Serial Interface'. The SPI Port handles SCLK, CSB, SDO, and SDIO signals. The Control Interface manages CPIO1, GPIO2, GPIO3, and GPIO#. The JESD204B/C interface handles SYNCIN, SERDES Out, SERDES In, and SYNC OUT signals. A 'DPD Engine' is also shown. Optional features are highlighted in grey, including the Observation Receiver, the DPD Engine, and the JESD204B/C Serial Interface. + +**Figure 2-18: Transceiver Reference Design Diagram (Optional elements are highlighted in Grey)** + +The definition of the input/output lines are as follows: + +- REF Clock In is the differential reference input to the on-chip synthesizer. This may also function as the SERDES Device Clock. +- SYSREF is a JESD204B/C differential synchronization signal. +- Ext LO/Clock Input is an optional input that can be used as an alternate LO or clocking signal. +- Rx1 through Rx4 are differential receiver inputs to their respective cores. +- Tx1 through Tx4 are differential transmitter output from their respective cores. +- ORx1 through ORx4 are differential observation receiver inputs. +- SCLK is the serial control clock input. +- CSB is the active low device select for the control interface. +- SDO is the serial data output for the control interface. This pin may be omitted for 3-pin control implementations. +- SDIO is a bidirectional serial data interface. In 4-pin mode, this pin functions as the serial data input. +- GPIO1 – GPIO# are general purpose IO signals used for interrupts, enables, test mode and resets. These are used as interface and control for peripheral devices including controllers, TxVGAs, PA, LNA and similar devices where SPI control is too slow. +- SYNCIN are differential pins associated with the receiver channels of the JESD204 interface. In not used, they are typically grounded. Up to 4 pair may be supported. +- SERDES Out are differential JESD204B/C data output interfaces. Up to 8 lanes may be active. + +- SERDES In are differential JESD204B/C data input interfaces. Up to 8 lanes may be active. +- SYNCOUT are differential pins associated with the transmitter channels of the JESD204 interface. If not used, do not connect. Up to 4 pair may be supported. + +##### 2.3.2.2.2 Power Amplifier (PA) Reference Design + +The Power Amplifier boosts the RF output to the level required for the base station class. + +###### a. *Hardware Requirements* + +The PA should have large enough gain to reduce the need for an additional driver. This will reduce cost and PCB space. The output power should be at least 27dBm (30dBm for 500mW/port to compensate for the loss of switch and antenna filter). The ACLR should be greater than 47dBc according to the related 3GPP test mode. DPD is needed to reduce the power consumption. The P1 dB requirement is closely related to the DPD algorithm. + +**Table 2-17: PA Requirements** + +| Frequency band | Band41 | Band78 | Additional Information | +|--------------------|--------|------------------------------|----------------------------------------------------------------| +| Gain | >33dB | >33dB | | +| P3dB | >34dBm | >34dBm<br>>37dBm(500mW/port) | ACLR>=47dBc with DPD@100MHz NR<br>27dBm (30dBm for 500mW/port) | +| Input return loss | <-15dB | <-15dB | | +| Output return loss | <-15dB | <-15dB | | +| Switching Speed | <1us | <1us | | +| HD2 | >28dBc | >28dBc | CW 27dBm | +| HD3 | >30dBc | >30dBc | CW 27dBm | + +- Interface Require + +The interface requirements of the transmit PA are listed in Table 2-18. + +**Table 2-18: Interface requirements of the transmit PA** + +| Item Name | Description | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Enable | The enable input should be compatible with 1.8V logic and tolerate 3.3V as required. A logic high enables the PA. A logic low disables the device and places it in a minimum dissipation mode. | +| RF Outputs | RF outputs support 50-ohm single ended to properly interface to a directional coupler, isolator, switch or antenna. | +| RF Inputs | RF inputs should support 50 ohm, single ended match to the transceiver output or preamp. | +| RF power detector | Power detector (optional) | + +- Power Dissipation: Dissipation while enabled should not exceed ~3W. + +###### *b. Hardware Design* + +RF<sub>in</sub> is the input to the PA, RF<sub>out</sub> is the output of the PA. V<sub>cc</sub> and V<sub>bias</sub> are the power inputs of the PA. PAEN is the control pin to disable or enable the PA. The input and output should match to 50 ohm as much as possible to reduce the reflection. V<sub>cc</sub> and V<sub>bias</sub> need capacitors to reduce the DC power ripples and give a short route to reduce the RF energy leakage. Figure 2-19 shows the details. + +![PA Reference Design Diagram showing a power amplifier (PA) block with inputs RFIn, RFEN, and Vcc, and output RFout.](c577e9b3ac856919ff5e5d355882ef09_img.jpg) + +The diagram illustrates the reference design for a Power Amplifier (PA). It features a central triangular PA block. The input side has two lines: RFIn (the main signal input) and RFEN (the enable input). The output side has a single line labeled RFout. Power is supplied to the PA through two inputs: Vcc (the main power supply) and Vbias (the bias supply). The Vcc and Vbias inputs are shown as lines entering the top of the PA block. + +PA Reference Design Diagram showing a power amplifier (PA) block with inputs RFIn, RFEN, and Vcc, and output RFout. + +**Figure 2-19: PA Reference Design Diagram** + +##### 2.3.2.2.3 Low Noise Amplifier (LNA) Reference Design + +The purpose of the LNA is to boost the Rx signal to a level that can nominally interface directly to the transceiver. This block will typically be a 2-stage amplifier with a 2<sup>nd</sup> stage bypass. The frontend will also include a TR switch to shunt any Tx signal to a termination away from the amplifier. + +###### a. Hardware Requirements + +The requirements of the LNA are listed here. + +- Interface Requirements: The interface requirements of the transmit LNA are listed in Table 2-19. + +**Table 2-19: One stage LNA Requirements** + +| Parameter | Band 41 | Band 78 | Additional Information | +|--------------------|---------|---------|------------------------| +| NF | <1dB | <1dB | | +| Gain | >15dB | >15dB | | +| P1dB | >18dBm | >18dBm | | +| Input return loss | <-12dB | <-12dB | | +| Output return loss | <-15dB | <-15dB | | +| Switching Speed | <1us | <1us | | +| IP3 | >30dBm | >30dBm | 2 Tone CW -15dBm | +| K | >1 | >1 | up to f = 12.5 GHz | +| Max input power | >15dBm | >15dBm | | + +- Device Configuration: Single or dual device. +- Power Dissipation: Less than 500 mW for a dual when device is fully enabled in receive mode. +- RF Specifications: For LNA unit, it should have larger enough gain to reduce extra driver amplifier for cost and PCB space. The NF figure of LNA should small enough to overcome the loss of switch and filter. + +**Table 2-20: Two stage LNA Requirements** + +| Frequency band | Band41 | Band78 | Additional Information | +|----------------|--------|---------|------------------------| +| NF | <1 dB | <1.5 dB | | + +| | | | | +|--------------------|-------------------------------------------------|-------------------------------------------------|----------------------| +| Gain | High gain $\geq 32$ dB<br>Low gain $\geq 16$ dB | High gain $\geq 32$ dB<br>Low gain $\geq 16$ dB | | +| P1dB | $> 18$ dBm | $> 18$ dBm | | +| Input return loss | $< -12$ dB | $< -12$ dB | | +| Output return loss | $< -15$ dB | $< -15$ dB | | +| Switching Speed | $< 1$ $\mu$ s | $< 1$ $\mu$ s | | +| IP3 | $> 30$ dBm | $> 30$ dBm | 2 Tone CW -15 dBm | +| K | $> 1$ | $> 1$ | up to $f = 12.5$ GHz | +| Max input power | $> 15$ dBm | $> 15$ dBm | | + +###### b. Hardware Design + +The reference designs for one stage LNA and two-stage LNA are given. + +###### - One stage LNA + +RFin is the input port of the LNA. RFout is the output of the LNA. Vcc is the power input of the LNA. LNA EN is the control pin to disable or enable the LNA. The input match to 50 ohm as much as possible to reduce the reflection. But for output of the LNA, it is hard to get best Noise figure and the output return loss. Compromise is needed between NF and return loss. Usually the return loss should be around -10dB or -12dB. Also is should be very careful to assure the stability of the LNA in a large bandwidth. Vcc needs capacitors to reduce the DC power ripples and give a short route to reduce the RF energy leakage. Figure 2-20 shows the details. + +![Figure 2-20: One Stage LNA Diagram. A schematic diagram of a one-stage Low Noise Amplifier (LNA). It features a central triangular amplifier symbol. The input port on the left is labeled 'RFin'. The output port on the right is labeled 'RFout'. The power supply input at the top is labeled 'Vcc'. The enable/disable control input at the bottom is labeled 'LNAEN'.](99b2ccb9602e5c66655e6ba487375c27_img.jpg) + +Figure 2-20: One Stage LNA Diagram. A schematic diagram of a one-stage Low Noise Amplifier (LNA). It features a central triangular amplifier symbol. The input port on the left is labeled 'RFin'. The output port on the right is labeled 'RFout'. The power supply input at the top is labeled 'Vcc'. The enable/disable control input at the bottom is labeled 'LNAEN'. + +Figure 2-20: One Stage LNA Diagram + +###### - Two stage LNA + +RFin is the input port of the LNA. RFout is the output of the LNA. Vcc is the power input of the LNA. LNA EN is the control pin to disable or enable the LNA. The input matches to 50 ohm as much as possible to reduce the reflection. But for output of the LNA, it is hard to get best Noise figure and the output return loss. Compromise is needed between NF and return loss. Usually the return loss should be around -10dB or -12dB. Also is should be very careful to assure the stability of the LNA in a large bandwidth. Vcc needs capacitors to reduce the DC power ripples and give a short route to reduce the RF energy leakage. Figure 2-21 shows the details. + +![Figure 2-21: Two-Stage LNA Diagram. The diagram shows two cascaded Low Noise Amplifier (LNA) stages. The first stage has an input port labeled 'RFin' and a control pin labeled 'LNAEN'. The second stage has an output port labeled 'RFout' and a control pin labeled 'LNAEN'. Both stages are powered by 'Vcc' and have a common ground line. A signal line labeled 'LNAbypass' is shown below the ground line, indicating a bypass path for the LNA stages.](1bd7299d68bfe10405a552010f94042f_img.jpg) + +Figure 2-21: Two-Stage LNA Diagram. The diagram shows two cascaded Low Noise Amplifier (LNA) stages. The first stage has an input port labeled 'RFin' and a control pin labeled 'LNAEN'. The second stage has an output port labeled 'RFout' and a control pin labeled 'LNAEN'. Both stages are powered by 'Vcc' and have a common ground line. A signal line labeled 'LNAbypass' is shown below the ground line, indicating a bypass path for the LNA stages. + +**Figure 2-21: Two-Stage LNA Diagram** + +##### 2.3.2.2.4 RF Switch Reference Design + +For TDD use, the TX and RX links work spiritedly by time duplex. The switch is used to change the RF link according to the TDD duplex. In the TDD TX mode, the switch is switched to connect PA and antenna. In TDD RX mode, the switch is switched to LNA and antenna. + +###### *a. Hardware Requirements* + +The requirements of the RF switch are listed here. + +- Interface Requirements + +The interface requirements of the switch are listed in Table 2-21. + +**Table 2-21: Interface requirements of the RF switch** + +| Item Name | Description | +|------------|----------------------------------------------------------------------------------------------------------| +| Control | Control the switch working mode | +| RF COM | The port connected to the antenna<br>RF inputs should support 50 ohm, single ended to match the antenna. | +| RF Outputs | The port connected to the LNA.<br>RF inputs should support 50 ohm, single ended to match the LNA. | +| RF Inputs | The port connected to the PA. | + +RF inputs should support 50 ohm, single ended to match the PA output. + +###### - RF Specifications + +For switch, it should have larger P1dB to not degrade the ACLR or damage the switch itself. The output power should be at least 26dBm (29dBm for 500mW/port) count on the loss of antenna filter so it must have low loss. Also the isolation needs to be high to protect the LNA. Higher HD2 and HD3 are needed to reduce the out of band emissions. + +**Table 2-22: RF Switch Requirements** + +| Frequency band | Band 41 | Band 78 | Additional Information | +|--------------------|---------|------------------------------|------------------------| +| Loss | <0.8dB | <0.8dB | | +| P1dB | >36dBm | >36dBm<br>>39dBm(500mW/port) | | +| Input return loss | <-15dB | <-15dB | | +| Output return loss | <-15dB | <-15dB | | +| Switching Speed | <1us | <1us | | +| Isolation | >30dB | >30dB | | +| HD2 | >70dBc | >70dBc | CW 27dBm | +| HD3 | >70dBc | >70dBc | CW 27dBm | + +###### **b. Hardware Design** + +RF Com is the input port of the switch, also can be the output of the switch. RF in is the input of the switch. RF out is the output of the switch. Control 1 and control 2 are the control pin to switch the RFin to RF Com or from RF Com to RF out. Figure 2-22 shows the details. + +![Figure 2-22: RF Switch Reference Design Diagram. A block diagram of an RF switch. A central square block has a diagonal line from the top-left to the bottom-right. On the left side, there are two input ports labeled 'RFin' (top) and 'RFout' (bottom). On the right side, there is one output port labeled 'RF com'. Above the block is a port labeled 'Control1' with a line connecting to the top of the block. Below the block is a port labeled 'Control2' with a line connecting to the bottom of the block.](592c3bc69e75d00f8107318d7039bba4_img.jpg) + +Figure 2-22: RF Switch Reference Design Diagram. A block diagram of an RF switch. A central square block has a diagonal line from the top-left to the bottom-right. On the left side, there are two input ports labeled 'RFin' (top) and 'RFout' (bottom). On the right side, there is one output port labeled 'RF com'. Above the block is a port labeled 'Control1' with a line connecting to the top of the block. Below the block is a port labeled 'Control2' with a line connecting to the bottom of the block. + +**Figure 2-22: RF Switch Reference Design Diagram** + +##### 2.3.2.2.5 Antenna Reference Design + +The antenna is used to radiate the TX power on to the air and receive the RX power from the air. For indoor Picocell scenario, the isotropic antenna is the first choice. + +###### *a. Hardware Requirements* + +The following table shows the antenna requirement for the O-RU<sub>7-2</sub>. + +**Table 2-23: Antenna Requirements** + +| Frequency band | Band 41 | Band 78 | +|-------------------------------------------|-----------------|-----------------| +| VSWR | $\leq 1.8$ | $\leq 1.8$ | +| Power capacity | $\geq 1$ W | $\geq 2$ W | +| Gain | $\geq 2$ dBi | $\geq 2.5$ dBi | +| Beam width on vertical direction | $\geq 35^\circ$ | $\geq 35^\circ$ | +| pattern roundness on horizontal direction | $\pm 3$ dB | $\pm 3$ dB | + +###### *b. Hardware Design* + +One possible choice of the isotropic antenna is the whip antenna. Following figure shows a design of one kind + +![A vertical whip antenna design, consisting of a long, thin, tapered metal rod with a small circular base at the bottom and a small circular cap at the top.](4e5c4be0b9faa9d99f7b27993f51ca4f_img.jpg) + +A vertical whip antenna design, consisting of a long, thin, tapered metal rod with a small circular base at the bottom and a small circular cap at the top. + +of whip antenna. + +**Figure 2-23: Whip Antenna** + +### 2.3.3 Synchronization and Timing + +The purpose of the Clocking device is to accept the network reference clock, typically 1 pps, and generate a jitter free reference clock(s) for other devices in the system including the RF transceiver and digital block. The clock is typically part of an IEEE 1588 implementation either controlled by an external stack or implemented in the clock device itself which could be part of the baseband implementation. + +##### *a. Hardware Requirements* + +Hardware requirements are: + +- Interface Requirements: The interface requirements of the transmit Clocking are listed in Table 2-24. + +**Table 2-24: Interface requirements of the clocking** + +| Item Name | Description | +|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Clock Input | The clock device should receive a network reference clock from the FPGA/ASIC. This typically could be a 1pps, 10 MHz or other standard reference as determined by the specific implementation. More than one input is allowed that may be selected between when the reliability of one reference is compromised. Standard differential clocking should be used to preserve signal integrity. | +| Control | Control of the transceiver is by way of 3 or 4 wire SPI or IIC functioning as a slave. Support for 1.8V control is required and tolerance of 3.3V is preferred. Typically, the clock devices will be part of an IEEE1588v2 protocol loop controlled by way of this control interface or other GPIO lines as required by the hardware implementation. | +| Clock Outputs | One or more clock outputs are required to drive the digital device and transceiver clock inputs. Each output should be independently programmable in frequency to suit the application. The outputs should nominally be differential to preserve clocking edge and to maximize tolerance of high common mode signals. | +| RF Inputs | RF inputs should support 50 ohm or 100 ohms, single ended or differential signalling to match the transceiver output. | + +- Power Dissipation: Total dissipation should be about less than 2W. +- RF Specifications: Clocking RF requirements are given in the following table. + +**Table 2-25: Clocking RF requirements** + +| Absolution Phase Noise, Dual Loop | Typical | Additional Information | +|-----------------------------------|---------|------------------------| +|-----------------------------------|---------|------------------------| + +| Mode - LVDS OUTPUT | | | +|------------------------------------------------------|-------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| $f_{OUT} = 122.88 \text{ MHz}$ | | Example is using an external 122.88 MHz VCXO (Crystek CVHD-950); reference = 122.88 MHz; channel divider = 10 or 1; PLL2 loop bandwidth (LBW) = 450 kHz. | +| 10 Hz Offset | -86 dBc/Hz | | +| 100 Hz Offset | -106 dBc/Hz | | +| 1 kHz Offset | -126 dBc/Hz | | +| 10 kHz Offset | -135 dBc/Hz | | +| 100 kHz Offset | -139 dBc/Hz | | +| 800 kHz Offset | -147 dBc/Hz | | +| 1 MHz Offset | -148 dBc/Hz | | +| 10 MHz Offset | -157 dBc/Hz | | +| 40 MHz Offset | -158 dBc/Hz | | +| Absolute Phase Noise, Single Loop Mode – LVDS OUTPUT | Typical | | +| LVDS OUTPUT | | | +| $f_{OUT} = 122.88 \text{ MHz}$ | | Example is using an external 122.88 MHz reference (SMA100A generator); reference = 122.88 MHz; channel divider = 10; PLL2 LBW = 450 kHz. | +| 10 Hz Offset | -111 dBc/Hz | | +| 100 Hz Offset | -113 dBc/Hz | | +| 1 kHz Offset | -123 dBc/Hz | | +| 10 kHz Offset | -135 dBc/Hz | | +| 100 kHz Offset | -140 dBc/Hz | | +| 800 kHz Offset | -147 dBc/Hz | | +| 1 MHz Offset | -148 dBc/Hz | | +| 10 MHz Offset | -157 dBc/Hz | | +| 40 MHz Offset | -157 dBc/Hz | | +| CLOCK OUTPUT ADDITIVE TIME JITTER (BUFFER MODE) | Typical | Example is using an external 122.88 MHz source driving VCXO inputs (distribution section only, does not include PLL and VCO) | +| $f_{OUT} = 122.88 \text{ MHz}$ | 79 fS | Integrated BW = 200 kHz to 5 MHz | +| | 101 fS | Integrated BW = 200 kHz to 10 MHz | + +| | | | +|--|--------|----------------------------------| +| | 140 fS | Integrated BW = 12 kHz to 20 MHz | +| | 187 fS | Integrated BW = 10 kHz to 40 MHz | +| | 189 fS | Integrated BW = 1 kHz to 40 MHz | +| | 176 fS | Integrated BW = 1 MHz to 40 MHz | + +1 + +2 + +##### b. Hardware Design + +For the clocking function, it is usually performed by a synchronization IC which may include one or more PLLs. And it also can supply numbers of output port to support different frequency clocking. + +![Figure 2-24: PLL Reference Design Diagram. This block diagram illustrates the internal architecture of a PLL reference design. It features two main PLL blocks, PLL 1 and PLL 2. PLL 1 is a fractional-N PLL that takes differential reference inputs REFA and REFB, selected by REF_SEL, and processes them through 10-bit dividers and a switch-over control to a lock detector and loop filter. It includes a charge pump and a 10-bit divider. PLL 2 is a fractional-N PLL that takes an external SYSREF input, which can be selected from an internal source or an external source via a multiplexer. It includes a 5-bit divider, a charge pump, a loop filter, and a divider with a range of +3 to +4. The diagram also shows various control and status pins: SDIO, SDO, SCLK, SPI, RESET, Status_0,1, and SPI_0,1. External components like LF1, VCXO_VT, VCXO_IN, LF2_EXT_CAP, and LDO_VCO are shown. The output section includes 8-bit dividers with coarse delays and fine delays, providing outputs OUT0 through OUT13.](44870046fd66cb8ac355cf608efba739_img.jpg) + +Figure 2-24: PLL Reference Design Diagram. This block diagram illustrates the internal architecture of a PLL reference design. It features two main PLL blocks, PLL 1 and PLL 2. PLL 1 is a fractional-N PLL that takes differential reference inputs REFA and REFB, selected by REF\_SEL, and processes them through 10-bit dividers and a switch-over control to a lock detector and loop filter. It includes a charge pump and a 10-bit divider. PLL 2 is a fractional-N PLL that takes an external SYSREF input, which can be selected from an internal source or an external source via a multiplexer. It includes a 5-bit divider, a charge pump, a loop filter, and a divider with a range of +3 to +4. The diagram also shows various control and status pins: SDIO, SDO, SCLK, SPI, RESET, Status\_0,1, and SPI\_0,1. External components like LF1, VCXO\_VT, VCXO\_IN, LF2\_EXT\_CAP, and LDO\_VCO are shown. The output section includes 8-bit dividers with coarse delays and fine delays, providing outputs OUT0 through OUT13. + +**Figure 2-24: PLL Reference Design Diagram** + +REFA and REFB are differential reference clock inputs from the source to be cleaned up and used as the system reference. REF\_SEL is the control pin used to select between REFA and REFB signals. LF1 is PLL1 external loop filter. VCXO\_VT is the VCXO control voltage. This pin is connected to the voltage control pin of the external VCXO. VCXO\_IN are differential signals from the external VCXO. These typically can be configured for single ended operation as well. LF2\_CAP is the external loop filter capacitor for loop 2. This cap is connected between this pin and LDO\_VCO pin. LDO\_VCO is the onchip LDO regular decoupling for the VCO. RESET(bar) is an active low pin to reset the internal logic to their default states. CS(bar) is an active low chip select for serial control. SCLK/SCL is a serial control port clock for both SPI and I2C. SDIO/SDA is a bidirectional serial data pin for both SPI and I2C. SDO is the serial data out pin for 4-wire mode. OUT0 through OUT13 are differential programmable output clock signals. These are the primary outputs of this device and provide high performance clock signals to the transceiver, baseband device and other key elements. This device is also responsible for providing SYSREF to various devices in the system if required. It may also use an external SYSREF as a source that may be retimed for local timing if necessary. STATUS0/SP0 is a lock detect and other status signal. STATIS1/SP1 is a lock detect and other status signal. SYSREF\_IN is an external SYSREF input clock is a differential input representing the JESD204 synchronization from the external source. + +### 2.3.4 External Interface Ports + +#### a. Hardware Requirements + +The following table shows the external ports or slots provided by O-RU<sub>7-2</sub>. + +**Table 2-26: External Port List** + +| Port Name | Feature Description | +|---------------------|---------------------------------------| +| Fronthaul interface | One 10Gbps SFP+ transceiver interface | +| | Or one RJ45 Ethernet interface | +| Debug interface | RJ45 for debug usage | +| Power interface | Two-pin male plug for power cable | + +#### **b. Hardware Design** + +- SFP+ case and connector: The SFP+ case and connector are standardized component on the market; following figure describe the form factor of one SFP case which is integrated with connector. + +![3D perspective view of an SFP+ case and connector. The device is rectangular with a series of pins along one edge and a connector interface on the other. It has several circular holes on top and a small label area.](dc86c774296a631cbe87b2328cefa177_img.jpg) + +3D perspective view of an SFP+ case and connector. The device is rectangular with a series of pins along one edge and a connector interface on the other. It has several circular holes on top and a small label area. + +**Figure 2-26: SFP+ case and connector** + +- RJ45 Ethernet interface: The RJ45 Ethernet interface is standardized component on the market; following figure describe the form factor of one RJ45 interface. + +![3D perspective view of an RJ45 Ethernet interface. It shows a standard RJ45 port with a latch and a series of pins inside. The device is rectangular and has a small label area.](20f7116cdfe2e241914ee5c706fce8b9_img.jpg) + +3D perspective view of an RJ45 Ethernet interface. It shows a standard RJ45 port with a latch and a series of pins inside. The device is rectangular and has a small label area. + +**Figure 2-26: RJ45 interface** + +### 2.3.5 Mechanical + +The shell of O-RU<sub>7-2</sub> is showing in the following figure. The O-RU<sub>7-2</sub> should be quiet, so it depends on the natural heat dissipation method. Usually the bottom of the shell is built by metal. All hot component should make its surfaces contact to metal shell through thermal pad. + +![Figure 2-27: O-RU7-2 Shell Mechanical Diagram. A 3D perspective drawing of a square-shaped electronic device with rounded corners. The top surface is covered with a grid of small circular holes. The sides of the device feature vertical cooling fins. Dimension lines indicate the overall width and depth are 229 units, and the height is 68.5 units.](f457e54b77f9640321021ed52e40acae_img.jpg) + +Figure 2-27: O-RU7-2 Shell Mechanical Diagram. A 3D perspective drawing of a square-shaped electronic device with rounded corners. The top surface is covered with a grid of small circular holes. The sides of the device feature vertical cooling fins. Dimension lines indicate the overall width and depth are 229 units, and the height is 68.5 units. + +**Figure 2-27: O-RU<sub>7-2</sub> Shell Mechanical Diagram** + +### 2.3.6 Power Unit + +For Picocell, for the power solution of the O-RU<sub>7-2</sub> can be over Ethernet cable (cat5E, cat6A) by POE (POE+, POE++) or directly power cable with fibre. And for the board power solution, LDO and DCDC can be used. + +#### *a. Hardware Requirements* + +For PA unit, it should have larger enough gain to reduce extra driver amplifier for cost and PCB space. The output power should be at least 27dBm count on the loss of switch and antenna filter. The ACLR should larger than 47dBc according to the related 3GPP test mode. To reduce the power consumption, DPD is needed. And the P1 dB requirement is closely related to the DPD algorithm. + +**Table 2-27: power unite requirement for 2T2R and 4T4R O-RU<sub>7-2</sub>** + +| Module | Power consumption | +|--------|-------------------| +|--------|-------------------| + +| | 2T2R | 4T4R | Unit | | +|---------------------------------------|------|-------|------|--------------------------------| +| FPGA | 9 | 11 | W | | +| Transceiver | 5.74 | 11.48 | W | | +| PLL | 1.78 | 1.78 | W | | +| PA | 5 | 10 | W | 0.75 TDD ratio | +| LAN | 0.15 | 0.3 | W | 0.25 TDD ratio | +| Ethernet PHY | 1 | 1 | W | | +| DDR | 0.9 | 0.9 | W | | +| Flash | 0.1 | 0.1 | W | | +| others | 1.65 | 1.65 | W | | +| component total power consumption | 25.3 | 38 | W | | +| O-RU <sub>7-2</sub> power consumption | 29.7 | 45 | W | on board power efficiency 0.85 | + +**Table 2-28: Power unite function** + +| Function | Priority | | +|----------------|-----------|----------------------------------------------------| +| Enable/Disable | Mandatory | | +| Power good | Optional | | +| Input voltage | Mandatory | 48V | +| Output voltage | Mandatory | 0.85V 1.2V 1.3V 1.5V 1.8V<br>2.5V 3.3V 5V 12V etc. | + +#### **b. Hardware Design** + +The block diagram of POE reference design is shown in Figure 2-28. Data Pair and Spare Pair are the POE connections on the data transformers used to source the power over Ethernet. $V_{AUX}$ is a local backup power source if desired. Isolated Output is the isolated raw output from the PoE sub-circuit. + +![Figure 2-28: PoE Reference Design Diagram. This schematic diagram illustrates the power delivery architecture for a Power over Ethernet (PoE) system. It features a central 'Power over Ethernet Controller' block with pins for VPORT, HSGATE, HSSRC, AUX, PWRGD, and GND. The controller is connected to an 'Isolated Power Supply' which provides V_IN and has an 'Isolated Output'. The power supply's output is filtered by a capacitor C_PORT. The controller's VPORT pin is connected to a network of components including a 3.3k resistor, a 47nF capacitor, and a diode. The HSGATE pin is connected to a MOSFET gate, which in turn drives the V_PORT line. This line also includes a 0.1uF capacitor (C_PD) and a diode. The V_PORT line is connected to two transformer-based couplers labeled 'DATA PAIR' and 'SPARE PAIR'. The entire system is powered by an auxiliary supply V_AUX (9V to 60V) which is connected to the controller's AUX pin and the V_PORT line through a resistor. Ground connections are shown throughout the circuit.](b20236b258244fa0337a0ad4cda70b70_img.jpg) + +Figure 2-28: PoE Reference Design Diagram. This schematic diagram illustrates the power delivery architecture for a Power over Ethernet (PoE) system. It features a central 'Power over Ethernet Controller' block with pins for VPORT, HSGATE, HSSRC, AUX, PWRGD, and GND. The controller is connected to an 'Isolated Power Supply' which provides V\_IN and has an 'Isolated Output'. The power supply's output is filtered by a capacitor C\_PORT. The controller's VPORT pin is connected to a network of components including a 3.3k resistor, a 47nF capacitor, and a diode. The HSGATE pin is connected to a MOSFET gate, which in turn drives the V\_PORT line. This line also includes a 0.1uF capacitor (C\_PD) and a diode. The V\_PORT line is connected to two transformer-based couplers labeled 'DATA PAIR' and 'SPARE PAIR'. The entire system is powered by an auxiliary supply V\_AUX (9V to 60V) which is connected to the controller's AUX pin and the V\_PORT line through a resistor. Ground connections are shown throughout the circuit. + +Figure 2-28: PoE Reference Design Diagram + +### 2.3.7 Thermal + +O-RU<sub>7-2</sub> will use passive cooling. + +### 2.3.8 Environmental and Regulations + +The O-RU<sub>7-2</sub> hardware system is RoHS Compliant. The power supply unit is EMC FCC/CISPR Class B compliant. + +Table 2-29 lists the environmental related features and parameters. + +Table 2-29: Environmental Features + +| Item Name | Description | +|---------------------------------|----------------------------| +| Operating Temperature | -5°C to +55°C | +| Non-operating Temperature | -40°C to 70°C | +| Operating Relative Humidity | 8% to 90% (non-condensing) | +| Non-operating Relative Humidity | 5% to 95% (non-condensing) | + +## 2.4 FHM<sub>7-2</sub> Hardware Reference Design + +The FHM<sub>7-2</sub> is used to bridge the connection between O-DU<sub>7-2</sub> and O-RU<sub>7-2</sub>. It needs to power the O-RU<sub>7-2</sub> and reduces the front haul bandwidth. + +### 2.4.1 FHM<sub>7-2</sub> High-Level Functional Block Diagram + +Figure 2-29 shows the FHM<sub>7-2</sub> block diagram for this reference design. Following sections below describe the functionality, interface and performance for each respective block of the Digital Processing Unit. As device integration is an ongoing activity, chip boundaries may be fluid and some functionality may move from one block to another or entire functionalities may be absorbed into other blocks. The sections below describe the functional blocks independent of which physical device they may reside in. + +![Figure 2-29: FHM7-2 General Block Diagram. The diagram shows a central 'FPGA+ARM' block. It is connected to a 'Power' block which receives '220V AC' and outputs '48V' to 'Power interface1' and 'Power interface8'. The 'FPGA+ARM' block has an 'RS232' interface connected to an 'RJ45' port. It also has two '25G SFP+' ports, one labeled 'Uplink' and the other 'Cascade'. The 'FPGA+ARM' block is connected to 'DDR' and 'Flash' memory, and a 'CLK' (clock) signal. It also has two 'Serdes' (serializer/deserializer) interfaces connected to '10G SFP+.1' and '10G SFP+.8' ports. A 'FAN' is also shown.](a585f78e55b1a702c0345dec436176b9_img.jpg) + +Figure 2-29: FHM7-2 General Block Diagram. The diagram shows a central 'FPGA+ARM' block. It is connected to a 'Power' block which receives '220V AC' and outputs '48V' to 'Power interface1' and 'Power interface8'. The 'FPGA+ARM' block has an 'RS232' interface connected to an 'RJ45' port. It also has two '25G SFP+' ports, one labeled 'Uplink' and the other 'Cascade'. The 'FPGA+ARM' block is connected to 'DDR' and 'Flash' memory, and a 'CLK' (clock) signal. It also has two 'Serdes' (serializer/deserializer) interfaces connected to '10G SFP+.1' and '10G SFP+.8' ports. A 'FAN' is also shown. + +Figure 2-29: FHM<sub>7-2</sub> General Block Diagram + +### 2.4.2 FHM<sub>7-2</sub> Hardware Components + +#### 2.4.2.1 Digital Processing Unit + +The FHM<sub>7-2</sub> need a lot of high speed interface. And for the shared cell application, the uplink need combining function. + +##### i. FPGA Solution Design 1 + +In this section, the requirement and reference design based on FPGA are described. + +###### 1 a. FPGA Requirement + +2 The requirements are as follows: + +- 3 • Interface requirement are shown in Table 2-30 + +4 **Table 2-30: Interface requirements of the FPGA** + +| | | +|-------------|---------------------------------------------| +| Serdes lane | At least 8 lanes of bi-direction10Gb Serdes | +| | At least 2 lanes of bi-direction25Gb Serdes | + +###### 6 b. FPGA Design + +7 This unit handles multiple high speed interfaces and the digital signal processing. The main chipset is based on +8 FPGA with ARM multi-core processor while FPGA is responsible for high speed data processing and ARM cores +9 are mainly for configuration and management. + +10 The FPGA function is shown below: + +11 For the uplink processing, the eCPRI interface module is used to receiver eCPRI link form O-RU<sub>7-2</sub> and generate +12 the reference frequency and time slot for time and frequency synchronization. Then the eCPRI de-frame module +13 get the uplink IQ bit stream of the time domain the carrier from O-RU<sub>7-2</sub>. If the uplink IQ stream is compressed, +14 then it needs the de-compression module to translate them into original bit width. + +15 After that all the O-RU<sub>7-2</sub> uplink IQ streams are combined together and the precondition for the combine function is +16 that each stream from different O-RU<sub>7-2</sub> are aligned in time domain. + +17 Then the time domain IQ date go to the Low PHY function module to change to frequency domain IQ samples by +18 FFT. Other function is not detailed at here. + +19 If the FHM<sub>7-2</sub> can support two separate cells then the two cell uplink signal should be aggregated or interleaved +20 together. Then capture the IQ streams in the eCPRI frame and transmitted by eCPRI interface to the O-DU<sub>7-2</sub>. + +21 For the downlink processing, the procedure is much the same with uplink but with an inverse sequence. The +22 difference is that the downlink signal is duplicated with 8 copies and sends to different O-RU<sub>7-2</sub>. + +23 There is also a eCPRI OAM module; actually this module will work with the processor (Arm) to accommodate the +24 OAM of different O-RU<sub>7-2</sub> and the FHM<sub>7-2</sub> itself. + +![Figure 2-30: FHM7-2 Digital Processing Block Diagram. The diagram shows two main processing paths. The top path is a receive chain: eCPRI interface -> eCPRI de-frame -> De-compress -> Buffer -> I/Q combinati on -> Other cell aggregati on -> Compression -> eCPRI frame -> eCPRI interface. The bottom path is a transmit chain: eCPRI interface -> eCPRI de-frame -> Other cell aggregati on -> I/Q mux -> Buffer -> eCPRI frame -> eCPRI interface. There are three parallel instances of the top path and three parallel instances of the bottom path. An 'Other cell' input is shown entering the 'Other cell aggregati on' block. An 'Ethernet OAM' block is shown connected to the 'Other cell aggregati on' block.](9f0de6ba4f3ad9264276436809c17582_img.jpg) + +Figure 2-30: FHM7-2 Digital Processing Block Diagram. The diagram shows two main processing paths. The top path is a receive chain: eCPRI interface -> eCPRI de-frame -> De-compress -> Buffer -> I/Q combinati on -> Other cell aggregati on -> Compression -> eCPRI frame -> eCPRI interface. The bottom path is a transmit chain: eCPRI interface -> eCPRI de-frame -> Other cell aggregati on -> I/Q mux -> Buffer -> eCPRI frame -> eCPRI interface. There are three parallel instances of the top path and three parallel instances of the bottom path. An 'Other cell' input is shown entering the 'Other cell aggregati on' block. An 'Ethernet OAM' block is shown connected to the 'Other cell aggregati on' block. + +**Figure 2-30: FHM7-2 Digital Processing Block Diagram** + +The resource needed for the FPGA is listed below: + +**Table 2-31: FPGA Resource usage for FHM7-2** + +| Device | FF | LUT | URAM | BRAM | DSP | +|----------------------|--------|-------|------|------|-----| +| IQ MUX | 1000 | 1000 | 0 | 0 | 0 | +| Cascade | 2000 | 2000 | 0 | 0 | 0 | +| IQ combine | 2000 | 2000 | 0 | 32 | 0 | +| eCPRI deframe*9 | 63000 | 63000 | 0 | 180 | 0 | +| eCPRI frame*9 | 63000 | 63000 | 0 | 180 | 0 | +| Fronthaul(eCPRI)x 10 | 100000 | 80000 | 0 | 10 | 0 | +| compress*1 | 3000 | 3000 | 0 | 24 | 32 | +| de_compress*8 | 24000 | 24000 | 0 | 192 | 208 | +| ethernet_cm | 3000 | 3000 | 0 | 15 | 0 | +| Other | 20000 | 15000 | 0 | 200 | 0 | + +### 2.4.3 Synchronization and Timing + +In this section we describe the internal and external timing and synchronization that are managed by this entity. + +#### a. Hardware Requirements + +- CLK requirement + +The FHM<sub>7-2</sub> may support some kinds of synchronization method: + +- 1) IEEE 1588/SyncE +- 2) Support GPS/GLONASS/GALILEO/BEIDOU + +So the PLL must support 1pps or eCPRI CDR as the reference frequency. + +**Table 2-32: Requirements of the PLL device** + +| Device | Description | +|---------------------|-------------| +| 1PPS | Supported | +| Synchronizer number | at least 1 | +| Output channel | At least 5 | +| VCO integrated | Supported | + +#### b. Hardware Design + +This unit is to recover clock from external source and generate the synchronized clock to other devices. Upon scenarios, there will be external sync source via eCPRI. + +![Figure 2-31: CLK reference design for FHM7-2. The diagram shows a central 'CLK' block. An input arrow from the left is labeled 'Reference clock from FPGA' and '390.625MHz'. Five output arrows point to the right from the 'CLK' block, labeled with frequencies: '390.625MHz', '156.25MHz', '156.25MHz', '125MHz', and '250MHz'. To the right of these arrows are their respective destinations: 'To FPGA 25G Serdes', 'To FPGA 10 Serdes0', 'To FPGA 10G Serdes1', 'For FPGA sys', and 'For DDR function'.](09cd4e4236847ca9fa10fed2f2be2bdc_img.jpg) + +Figure 2-31: CLK reference design for FHM7-2. The diagram shows a central 'CLK' block. An input arrow from the left is labeled 'Reference clock from FPGA' and '390.625MHz'. Five output arrows point to the right from the 'CLK' block, labeled with frequencies: '390.625MHz', '156.25MHz', '156.25MHz', '125MHz', and '250MHz'. To the right of these arrows are their respective destinations: 'To FPGA 25G Serdes', 'To FPGA 10 Serdes0', 'To FPGA 10G Serdes1', 'For FPGA sys', and 'For DDR function'. + +**Figure 2-31: CLK reference design for FHM<sub>7-2</sub>** + +For general FPGA device, each bank may have 4 Serdes channel. It is better to have separated clk to each bank. So two clk of 156.25 MHz are needed for the FHM<sub>7-2</sub>, which is used for the 8 10G serdes interfaces with O-RU<sub>7-2</sub>. One 390.625MHz is used for 2 25G serdes interface with O-DU<sub>7-2</sub> or cascaded FHM<sub>7-2</sub>. One 125MHz is + +used for FPGA system. One 250MHz clk for DDR device function. One 390.625MHz is used for 25G eCPRI interface between O-DU<sub>7-2</sub> and FHM<sub>7-2</sub>. The input of the CLK module comes from FPGA CDR function which get reference clk from the eCPRI line rate. Usually, one PLL device which is integrated with VCO is needed. + +### 2.4.4 External Interface Ports + +List and provide description of all external interfaces. + +#### a. Hardware Requirements + +The following table shows the external ports or slots provided by FHM<sub>7-2</sub>. + +**Table 2-33: External Port List** + +| Port Name | Feature Description | +|---------------------|------------------------------------------| +| Fronthaul interface | Eight 10Gbps SFP+ transceiver interfaces | +| | Two 25Gbps SFP+ transceiver interfaces | +| Debug interface | RJ45 for debug usage | +| Power interface | PLUG AC FEMALE for power cable | + +#### b. Hardware Design + +- SFP+ case and connector + +The SFP+ case and connector are standardized component on the market; following figure describes the form factor of one SFP case which is integrated with connector. + +![A 3D perspective drawing of an SFP+ (Small Form-factor Pluggable Plus) module. It is a rectangular component with a metal housing. On the front face, there are several circular holes for screws. On the side, there are multiple gold-plated pins or connectors protruding outwards, which are used for interfacing with a host system.](456adb8be00dc3e7a703144a95e63c0e_img.jpg) + +A 3D perspective drawing of an SFP+ (Small Form-factor Pluggable Plus) module. It is a rectangular component with a metal housing. On the front face, there are several circular holes for screws. On the side, there are multiple gold-plated pins or connectors protruding outwards, which are used for interfacing with a host system. + +**Figure 2-32: SFP+ case and connector** + +- RJ45 Ethernet interface + +The RJ45 Ethernet interface is standardized component on the market; following figure describes the form factor of one RJ45 interface. + +![Isometric view of an RJ45 network interface connector.](1aa5e5db4f0571bb197497ee1d8d775c_img.jpg) + +Isometric view of an RJ45 network interface connector. + +**Figure 2-33: RJ45 interface** + +- Power interface + +The 220V AC power connector is standardized component on the market; following figure describes the form factor of one 220V AC power connector. + +![Technical drawing of a 220V AC power connector showing side and front views with dimensions.](4e4e3b9b754c1377dfbacac001247a56_img.jpg) + +Technical drawing of a 220V AC power connector showing side and front views with dimensions. + +**Figure 2-34: AC power interface** + +### 2.4.5 Mechanical + +The 1U rack mount chassis can contains the layout of the power unit and processing unit. The shell of FHM<sub>7-2</sub> is showing in the following figure. The power consumption of FHM<sub>7-2</sub> is huge, so it may need a fan to accelerate the heat dissipation. + +![Isometric view of a 1U rack mount chassis with dimensions: 440, 482, 250, and 44.](e02b7368461b4e84ef53b64683feb2cb_img.jpg) + +Isometric view of a 1U rack mount chassis with dimensions: 440, 482, 250, and 44. + +**Figure 2-35: Shell Mechanical Diagram** + +### 2.4.6 Power + +At minimum, fully describe the power consumptions for this white box. Include all AC/DC input or outputs and their ratings. Not mandatory but if you like you can add summary of all component's power requirement and overall white box. + +#### *a. Hardware Requirements* + +- Power requirement: The power solution is divided into two parts. + 1. Input power module: This power module must support AC to DC conversion. Usually it converts 220V AC to 48V DC. + 2. Output power module: It will supply power to the O-RU<sub>7-2</sub> connected to the FHM<sub>7-2</sub> and also the device on the FHM<sub>7-2</sub> itself. + +**Table 2-34: Requirements of the power unit** + +| Item | Description | +|----------------|---------------| +| Input voltage | AC:100V~264V | +| Output voltage | DC: 48V | +| Output power | At least 600W | + +#### *b. Hardware Design* + +Describe hardware reference design for this power unit. + +This unit has two main functions which are internal power supply and external/remote power supply. The input power is normally AC (100V to 250V) but DC input could be optional. For remote power supply, it will support -48V DC via either standalone cable or cat-6A cable. + +Usually a separated AC-DC power supply is used for the 220V to 48V conversion. It is very common power supply on the market. + +It should have fan to cool itself and handle for easy plug in and out. + +Then the output power is divided into two portions. One for O-RU<sub>7-2</sub> power supply, the other is for the device on the FHM<sub>7-2</sub> board. + +For the on-board power solution, 48V to 12V converter is needed as standard 1/8 brick module. Then the power voltage is further changer to lower level such as 5V, 3.3V, 1.1V, 1.0V and so on by DC/DC or LDO devices. + +### 2.4.7 Thermal + +Active cooling. + +### 2.4.8 Environmental and Regulations + +The FHM<sub>7-2</sub> will fulfil the requirement in 4.6.3 of [6]. + +## 2.5 FHGW<sub>7-2→8</sub> Hardware Reference Design + +The FHGW<sub>7-2→8</sub> is used to bridge the connection between O-DU<sub>7-2</sub> and O-RU<sub>8</sub>. It needs to power the O-RU<sub>8</sub> and reduces the front haul bandwidth. + +### 2.5.1 FHGW<sub>7-2→8</sub> High-Level Functional Block Diagram + +Figure 2-36 depicts the FHGW<sub>7-2→8</sub> block diagram for this reference design. Following sections will describe the functionality, interface and performance for each respective block within the figure. Since device integration is an ongoing activity, chip boundaries may be fluid and some functionality may move from one block to another or entire functionalities may be absorbed into other blocks. The descriptions below describe the functional blocks independent of which physical device they may reside in. + +![Figure 2-36: FHGW7-2→8 General Block Diagram. The diagram shows a central 'FPGA+Processor' block. On the left, a 'Power' block receives '220V AC' and outputs '48V' to 'Power interface1' and 'Power interface8'. 'Power interface1' is marked with a '1' in a box. On the top left, an 'RJ45' block connects to an 'RS232' block, which then connects to the 'FPGA+Processor'. Above the 'FPGA+Processor' are two '25G SFP+' blocks, one labeled 'Uplink' and the other 'Cascade', both connected via bidirectional arrows. To the right of the 'FPGA+Processor' are 'DDR', 'Flash', and 'CLK' blocks, connected with bidirectional arrows. Below the 'FPGA+Processor' are two '10G SFP+.1' and '10G SFP+.8' blocks, connected via 'Serdes' blocks. A 'FAN' block is also shown on the right. 'Power interface8' is marked with a '1' in a box.](f7f50348cbcfb7b3a3295caf531eb069_img.jpg) + +Figure 2-36: FHGW7-2→8 General Block Diagram. The diagram shows a central 'FPGA+Processor' block. On the left, a 'Power' block receives '220V AC' and outputs '48V' to 'Power interface1' and 'Power interface8'. 'Power interface1' is marked with a '1' in a box. On the top left, an 'RJ45' block connects to an 'RS232' block, which then connects to the 'FPGA+Processor'. Above the 'FPGA+Processor' are two '25G SFP+' blocks, one labeled 'Uplink' and the other 'Cascade', both connected via bidirectional arrows. To the right of the 'FPGA+Processor' are 'DDR', 'Flash', and 'CLK' blocks, connected with bidirectional arrows. Below the 'FPGA+Processor' are two '10G SFP+.1' and '10G SFP+.8' blocks, connected via 'Serdes' blocks. A 'FAN' block is also shown on the right. 'Power interface8' is marked with a '1' in a box. + +Figure 2-36: FHGW<sub>7-2→8</sub> General Block Diagram + +### 2.5.2 FHGW<sub>7-2→8</sub> Hardware Components + +#### 2.5.2.1 Digital Processing Unit + +The FHGW<sub>7-2→8</sub> need a lot of high speed interface. It would need the function of transforming the FH protocol with split Option 8 to one of with split Option 7-2. This requires availability of the Low PHY function as required by option 7-2. For the shared cell application, the uplink will also need a combining function for aggregation and dis aggregation of data. + +##### i. *FPGA Design Solution 1* + +In this section, the requirement and reference design based on FPGA are described. + +##### a. *FPGA Requirement* + +- Interface requirement: Interface requirements for this FPGA design solution are provided in the following table. + +**Table 2-35: Interface Requirements of the FPGA** + +| Item Name | Description | +|-------------|---------------------------------------------| +| Serdes lane | At least 8 lanes of bi-direction10Gb Serdes | +| | At least 2 lanes of bi-direction25Gb Serdes | + +##### b. *FPGA Design* + +This unit handles multiple high speed interfaces and the digital signal processing. The main chipset is based on FPGA with multi-core processor while FPGA is responsible for high speed data processing and processor cores are mainly for configuration and management. + +The FPGA function is shown below: + +For the uplink processing, the CPRI interface module is used to receive CPRI link from O-RU<sub>8</sub> for generation of the reference frequency and time slot for time and frequency synchronization. Then the CPRI de-frame module gets the uplink IQ bit stream of the time domain the carrier from O-RU<sub>8</sub>. If the uplink IQ stream is compressed, then it needs the de-compression module to translate them into original bit width. All the O-RU<sub>8</sub> uplink IQ streams are combined and the precondition for the combine function is that each stream from different O-RU<sub>8</sub> are aligned in time domain. Then the time domain IQ data go to the Low PHY function module to change to frequency domain IQ samples by performing FFT function. + +If the FHGW<sub>7-2→8</sub> can support two separate cells then the two cell uplink signal should be aggregated or interleaved together. Then FHGW<sub>7-2→8</sub> should capture the IQ streams in the eCPRI frame and transmit it via eCPRI interface to the O-DU<sub>7-2</sub>. For the downlink processing, the procedure is very much the same as uplink but in reverse order. The difference is that the downlink signal is duplicated with 8 copies and transmits that + +to different O-RU<sub>8</sub>. There is also one eCPRI/CPRI OAM module. Actually this module will work with the processor to accommodate the OAM of different O-RU<sub>8</sub> and the FHGW<sub>7-2→8</sub> itself. + +![Figure 2-37: FHGW7-2→8 Digital Processing Block Diagram. The diagram shows two main processing paths. The top path (reception) starts with three parallel CPRI interfaces, each followed by a CPRI de-frame block, a De-compress block, and a Buffer. These buffers feed into an I/Q combination block, which then feeds into a Low-PHY block, followed by an Other cell aggregation block, a Compression block, an eCPRI frame block, and finally an eCPRI interface. The bottom path (transmission) starts with an eCPRI interface, followed by an eCPRI de-frame block, then a Low-PHY block, an Other cell aggregation block, and an I/Q mux. The I/Q mux feeds into three parallel Buffer blocks, each followed by a CPRI frame block and a CPRI interface. An Ethernet OAM block is shown as a dashed box, connected to the Other cell aggregation block and the I/Q mux. An 'Other cell' input is also shown feeding into the Other cell aggregation block.](7117ed3eff060bdb12c8f531495833b8_img.jpg) + +FHGW 7-2-8 + +Figure 2-37: FHGW7-2→8 Digital Processing Block Diagram. The diagram shows two main processing paths. The top path (reception) starts with three parallel CPRI interfaces, each followed by a CPRI de-frame block, a De-compress block, and a Buffer. These buffers feed into an I/Q combination block, which then feeds into a Low-PHY block, followed by an Other cell aggregation block, a Compression block, an eCPRI frame block, and finally an eCPRI interface. The bottom path (transmission) starts with an eCPRI interface, followed by an eCPRI de-frame block, then a Low-PHY block, an Other cell aggregation block, and an I/Q mux. The I/Q mux feeds into three parallel Buffer blocks, each followed by a CPRI frame block and a CPRI interface. An Ethernet OAM block is shown as a dashed box, connected to the Other cell aggregation block and the I/Q mux. An 'Other cell' input is also shown feeding into the Other cell aggregation block. + +**Figure 2-37: FHGW<sub>7-2→8</sub> Digital Processing Block Diagram** + +The FPGA resource needed for the FPGA is listed below: + +**Table 2-36: FPGA Resource Usage for FHGW<sub>7-2→8</sub>** + +| Device | FF | LUT | URAM | BRAM | DSP | +|--------------------|-------|-------|------|------|-----| +| IQ MUX | 1000 | 1000 | 0 | 0 | 0 | +| Cascade | 2000 | 2000 | 0 | 0 | 0 | +| IQ combine | 2000 | 2000 | 0 | 32 | 0 | +| eCPRI deframe*2 | 14000 | 14000 | 0 | 40 | 0 | +| eCPRI frame*2 | 14000 | 14000 | 0 | 40 | 0 | +| CPRI deframe*8 | 40000 | 40000 | 0 | 0 | 0 | +| CPRI frame*8 | 40000 | 40000 | 0 | 0 | 0 | +| Fronthaul(eCPRI)x2 | 20000 | 16000 | 0 | 2 | 0 | +| Fronthaul(CPRI)x8 | 37890 | 24804 | 0 | 8 | 0 | +| compress*1 | 3000 | 3000 | 0 | 24 | 32 | +| de_compress*8 | 24000 | 24000 | 0 | 192 | 208 | +| Ethernet CM | 3000 | 3000 | 0 | 15 | 0 | +| iFFT & CP+ | 7763 | 5323 | 0 | 27 | 23 | +| FFT & CP- | 7763 | 5323 | 0 | 27 | 23 | + +| | | | | | | +|-----------------|-------|-------|---|-----|----| +| PRACH front end | 4000 | 3000 | 0 | 32 | 50 | +| Other | 20000 | 15000 | 0 | 200 | 0 | + +### 2.5.3 Synchronization and Timing + +This section describes the synchronization and timing mechanism that is used in the FHGW<sub>7-2→8</sub>. + +#### a. Hardware Requirements + +- CLK requirement + +The FHGW<sub>7-2→8</sub> may support some kinds of synchronization method: + +- 1) IEEE 1588/SyncE +- 2) Support GPS/GLONASS/GALILEO/BEIDOU + +So the PLL must support 1pps or eCPRI CDR as the reference frequency. + +**Table 2-37: Requirements of the PLL device** + +| Item Name | Description | +|---------------------|-------------| +| 1PPS | Supported | +| Synchronizer number | at least 1 | +| Output channel | At least 6 | +| VCO integrated | Supported | + +#### b. Hardware Design + +This unit is to recover clock from external source and generate the synchronized clock to other devices. Upon scenarios, there will be external sync source via eCPRI. + +![Figure 2-38: CLK reference design for FHGW7-2→8. The diagram shows a central block labeled 'CLK' receiving a 'Reference clock from FPGA' (390.625MHz) on the left. On the right, the 'CLK' block outputs six different clock signals: 390.625MHz (To FPGA 25G Serdes), 122.88MHz (To FPGA 10 Serdes0), 122.88MHz (To FPGA 10G Serdes1), 125MHz (For FPGA sys), 250MHz (For DDR function), and 122.88MHz (For Low PHY function).](8e42b7b5756105fd87d4f6393fe881d0_img.jpg) + +Figure 2-38: CLK reference design for FHGW7-2→8. The diagram shows a central block labeled 'CLK' receiving a 'Reference clock from FPGA' (390.625MHz) on the left. On the right, the 'CLK' block outputs six different clock signals: 390.625MHz (To FPGA 25G Serdes), 122.88MHz (To FPGA 10 Serdes0), 122.88MHz (To FPGA 10G Serdes1), 125MHz (For FPGA sys), 250MHz (For DDR function), and 122.88MHz (For Low PHY function). + +**Figure 2-38: CLK reference design for FHGW<sub>7-2→8</sub>** + +For general FPGA device, each bank may have four Serdes channels. It is better to have separated CLK signal to each bank. Three CLK signals of 122.88MHz are needed for the FHGW<sub>7-2→8</sub>. One CLK signal of 125MHz is used for FPGA system, while one CLK signal of 250MHz is used for DDR device function. One CLK signal of 390.625MHz is used for 25G eCPRI interface between O-DU<sub>7-2</sub> and FHGW<sub>7-2→8</sub>, and one CLK signal of 122.8MHz is used for low PHY function. The input of the CLK module comes from FPGA CDR function which can get reference CLK from the sync-plane of eCPRI. Usually, one PLL device integrated with VCO and two separated synthesizers is needed. + +### 2.5.4 External Interface Ports + +This section describes the external interface ports that are needed in the FHGW<sub>7-2→8</sub>. + +#### a. Hardware Requirements + +The following table shows the external ports or slots provided by FHGW<sub>7-2→8</sub>. + +**Table 2-38: External Port List** + +| Port Name | Feature Description | +|---------------------|------------------------------------------| +| Fronthaul interface | Eight 10Gbps SFP+ transceiver interfaces | +| | Two 25Gbps SFP+ transceiver interfaces | +| Debug interface | RJ45 for debug usage | +| Power interface | PLUG AC FEMALE for power cable | + +#### b. Hardware Design + +- SFP+ case and connector + +The SFP+ case and connector are standardized component on the market; following figure describes the form factor of one SFP case which is integrated with connector. + +![A 3D perspective drawing of an SFP+ (Small Form-factor Pluggable Plus) module. It shows a rectangular metal housing with a series of gold-plated pins along one edge, forming a connector. The top surface of the module has several circular mounting holes and some smaller components or labels.](f45e3c6000b944e206d6a7f4618b9d03_img.jpg) + +A 3D perspective drawing of an SFP+ (Small Form-factor Pluggable Plus) module. It shows a rectangular metal housing with a series of gold-plated pins along one edge, forming a connector. The top surface of the module has several circular mounting holes and some smaller components or labels. + +**Figure 2-39: SFP+ case and connector** + +- RJ45 Ethernet interface + +The RJ45 Ethernet interface is standardized component on the market; following figure describes the form factor of one RJ45 interface. + +![Isometric drawing of an RJ45 network interface connector.](931f849e941982db7ffb65c79c3b7997_img.jpg) + +An isometric line drawing of a standard RJ45 network interface connector. It shows the rectangular plastic housing with the internal metal contacts visible at the front. A small tab on the side is used to lock the connector into a port. + +Isometric drawing of an RJ45 network interface connector. + +**Figure 2-40: RJ45 interface** + +- Power interface + +The 220V AC power connector is standardized component on the market; following figure describes the form factor of one 220V AC power connector. + +![Technical drawing of a 220V AC power connector showing dimensions and a side view.](5bab0fc869de7bd47cb622a8356254ed_img.jpg) + +A technical drawing of a 220V AC power connector. The left side shows a top-down view with dimensions: a total width of 17, a central opening width of 14, and a bottom flange width of 4. The right side shows a side profile view of the cylindrical connector with a threaded section at the end. + +Technical drawing of a 220V AC power connector showing dimensions and a side view. + +**Figure 2-41: AC power interface** + +### 2.5.5 Mechanical + +The 1U rack mount chassis can contain the layout of the power unit and processing unit. The shell of FHGW<sub>7-2→8</sub> is showing in the following figure. The power consumption of FHGW<sub>7-2→8</sub> is huge, so it may need a fan to accelerate the heat dissipation. + +![Figure 2-42: Shell Mechanical Diagram. A 3D isometric drawing of a 1U rack mount chassis. The chassis is rectangular with a front panel featuring multiple ports and a handle. A fan is mounted on top. Dimensions are indicated: 440mm for the front panel width, 482mm for the total width, 250mm for the depth, and 44mm for the height.](689cd6fcf86e335627e9e60156151bbd_img.jpg) + +Figure 2-42: Shell Mechanical Diagram. A 3D isometric drawing of a 1U rack mount chassis. The chassis is rectangular with a front panel featuring multiple ports and a handle. A fan is mounted on top. Dimensions are indicated: 440mm for the front panel width, 482mm for the total width, 250mm for the depth, and 44mm for the height. + +Figure 2-42: Shell Mechanical Diagram + +### 2.5.6 Power + +At minimum, fully describe the power consumptions for this white box. Include all AC/DC input or outputs and their ratings. Not mandatory but if you like you can add summary of all component's power requirement and overall white box. + +#### a. Hardware Requirements + +- Power requirement: The power solution is divided into two parts. + 1. Input power module +This power module must support AC to DC conversion. Usually it converts 220V AC to 48V DC. + 2. Output power module +It will supply power to the O-RU<sub>8</sub> connected to the FHGW<sub>7-2→8</sub> and also the device on the FHGW<sub>7-2→8</sub> itself. + +**Table 2-39: Power Unit Requirements** + +| Item Name | Description | +|----------------|---------------| +| Input voltage | AC:100V~264V | +| Output voltage | DC: 48V | +| Output power | At least 600W | + +#### **b. Hardware Design** + +This unit has two main functions which are internal power supply and external/remote power supply. The input power is normally AC (100V to 250V) but DC input could be optional. For remote power supply, it will support -48V DC via either standalone cable or cat-6A cable. Usually a separated AC-DC power supply is used for the 220V to 48V conversion. It is very common power supply on the market. It should have fan to cool itself and handle for easy plug in and out. Then the output power is divided into two portions. One for O-RU<sub>8</sub> power supply, the other is for the device on the FHGW<sub>7-2→8</sub> board. For the on board power solution, 48V to 12V converter is needed as standard 1/8 brick module. Then the power voltage is further changer to lower level such as 5V, 3.3V, 1.1V, 1.0V and so on by DC/DC or LDO devices. + +### 2.5.7 Thermal + +Active cooling shall be used for this fronthaul gateway. + +### 2.5.8 Environmental and Regulations + +This FHGW<sub>7-2→8</sub> will fulfil the requirements as described in 4.6.3 of [6]. + +# Annex 1: Parts Reference List + +According to WG7 scope and charter, component selection for example implementation of white box hardware is allowed for WG7 but would not be mandatory in any Specification. + +Recommended O-DU<sub>7-2</sub> parts reference is given in table below: + +| No. | Part Number | Descriptions | +|-----|--------------------------------------|---------------------------------------------| +| 1 | Intel® Xeon® Processor D-2183IT | Intel® Xeon® Skylake D D-2100 SoC processor | +| 2 | Intel® I350 | Intel® 1GbE x4 Ethernet controller | +| 3 | Intel® X557-AT2 | Intel® 10GbE x2 Ethernet controller | +| 4 | Intel® I210 | Intel® 1GbE Ethernet controller | +| 5 | ASPEED® AST-2500 | ASPEED® BMC controller | +| 6 | UniIC® SCQ08GU03H1F1C-26V | UniIC® DDR4 8GB | +| 7 | Powerleader® MTFDDAK480TDC-1AT1ZABYY | Powerleader® SSD 480GB | +| 8 | Accelink® RTXM228-551 | Accelink® 10Gbps Optical module | + +1 + +###### --- 2      **Annex 2              FHGW<sub>7-2→8</sub> Option 8 CPRI specification reference** 3              **design** + +4      Please refer to “Annex2 - CPRI specification reference design” in O-RAN.WG7.IPC-HRD-Opt8.0-v03.00, + 5      <https://www.o-ran.org/specifications>, reuse all contents except to replace the O-DU<sub>8</sub> with O-DU<sub>7-2</sub>, and replace the + 6      FHM<sub>8</sub> with FHGW<sub>7-2→8</sub> . + +7 + +###### --- 8      **Annex 3              FHGW<sub>7-2→8</sub> Option 8 CPRI spec reference design –** 9              **Management plane** + +10      Please refer to “Annex3 - Option 8 CPRI spec reference design – Management plane” in O-RAN.WG7.IPC-HRD- + 11      Opt8.0-v02.00, <https://www.o-ran.org/specifications>, reuse all contents except to replace the O-DU<sub>8</sub> with O-DU<sub>7-2</sub>, and + 12      replace the FHM<sub>8</sub> with FHGW<sub>7-2→8</sub>. + +13 + +# --- 14      **Annex 4              FHGW<sub>7-2→8</sub> management plane reference design** + +15 + +###### 16      **A4.1 Scope** + +17              This document specifies the management plane reference design for FHGW<sub>7-2→8</sub>. Except content specify here, + 18      other management function is based ORAN WG4 Management Plane Specification and reuse it. + +## 19      **A4.2 Reference** + +20              The following documents contain provisions which, through reference in this text, constitute provisions of the + 21      present document. + +22              - References are either specific (identified by date of publication, edition number, version number, etc.) or + 23      non-specific. + +24              - For a specific reference, subsequent revisions do not apply. + +25              - For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including + 26      a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 15. + +[1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications” + +[2] Interface Specification: “CPRI Specification Common Public Radio Interface (CPRI)”, V7.0, October 2015. + +[3] ORAN-WG4.CUS.0-v03.00 Technical Specification, ‘O-RAN Fronthaul Working Group Control, User and Synchronization Plane Specification’. <https://www.o-ran.org/specifications> + +[4] ORAN-WG4.MP.0-v03.00 Technical Specification, ‘O-RAN Fronthaul Working Group Control, Management Plane Specification’. <https://www.o-ran.org/specifications> + +## A4.3 Definitions and Abbreviations + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [1]. + +| Abbreviations | Full name | +|-----------------------|--------------------------------------------------------| +| C&M | Control and Management | +| CPRI | Common Public Radio Interface | +| LOF | Lost of Frame | +| LOS | Lost of Signal | +| LSB | Least Significant Bit | +| M-Plane | Management Plane | +| MSB | Most Significant Bit | +| O-DU <sub>7-2</sub> | O-RAN Distributed Unit with split option 7-2 | +| FHGW <sub>7-2→8</sub> | FHGW between O-DU <sub>7-2</sub> and O-RU <sub>8</sub> | +| O-RU <sub>8</sub> | O-RAN Radio Unit with split option 8 | +| RAI | Remote Alarm Indication | +| S-Plane | Synchronization Plane | +| SAP | Service Access Point | +| SDI | SAP Defect Indication | + +| | | +|---------|------------| +| U-Plane | User Plane | +|---------|------------| + +Note: If without clear clarification in this Annex, O-DU always refer to O-DU<sub>7-2</sub>, FHGW always refers to FHGW<sub>7-2→8</sub>, O-RU always refers to O-RU<sub>8</sub>. + +## A4.4 High Level Description + +This specification refers to following architecture model. + +From the perspective of the lower layer connection protocol, as shown in the following figure, the architecture model includes: + +- Ethernet/VLAN protocol connection is applied between O-DU<sub>7-2</sub> and FHGW<sub>7-2→8</sub> +- Ethernet/VLAN protocol connection is applied between FHGW<sub>7-2→8</sub> and FHGW<sub>7-2→8</sub> +- CPRI protocol connection is applied between FHGW<sub>7-2→8</sub> and O-RU<sub>8</sub> + +![Figure 1 Architecture-lower layer connection diagram. The diagram shows a hierarchical network structure. At the top is O-DU7-2, which contains an M-Client and an H-PHY. It is connected via an Ethernet Link (blue line) to FHGW7-2→8, which contains an M-Server and an L-PHY. FHGW7-2→8 is connected via CPRI Links (black lines) to a group of O-RU8-1-N (containing M-Server and RU SW) and another FHGW7-2→8 (containing M-Server and L-PHY). This second FHGW7-2→8 is then connected via CPRI Links to a group of O-RU8-2-M (containing M-Server and RU SW). A legend on the right defines the symbols: Ethernet Link (blue line), CPRI Link (black line), H-PHY (High PHY), L-PHY (Low PHY), M-Client (M-Plane Netconf Client), M-Server (M-Plane Netconf Server), and RU SW (RU Software).](e7d084b12ece9fc7f784e3f755256d67_img.jpg) + +Figure 1 Architecture-lower layer connection diagram. The diagram shows a hierarchical network structure. At the top is O-DU7-2, which contains an M-Client and an H-PHY. It is connected via an Ethernet Link (blue line) to FHGW7-2→8, which contains an M-Server and an L-PHY. FHGW7-2→8 is connected via CPRI Links (black lines) to a group of O-RU8-1-N (containing M-Server and RU SW) and another FHGW7-2→8 (containing M-Server and L-PHY). This second FHGW7-2→8 is then connected via CPRI Links to a group of O-RU8-2-M (containing M-Server and RU SW). A legend on the right defines the symbols: Ethernet Link (blue line), CPRI Link (black line), H-PHY (High PHY), L-PHY (Low PHY), M-Client (M-Plane Netconf Client), M-Server (M-Plane Netconf Server), and RU SW (RU Software). + +**Figure 1 Architecture-lower layer connection** + +From M-Plane perspective, as shown in the figure below, this architecture model includes: + +- NETCONF client is deployed in O-DU<sub>7-2</sub> +- NETCONF server is deployed in FHGW<sub>7-2→8</sub> and O-RU<sub>8</sub> +- O-DU and FHGW<sub>7-2→8</sub> are connected with NETCONF management protocol +- O-DU and O-RU<sub>8</sub> are connected with NETCONF management protocol + +![Figure 2 Architecture M-Plane connection diagram. The diagram shows a hierarchical network structure. At the top is O-DU7-2, which contains an M-Client and an H-PHY. Below it is FHGW7-2->8, which contains an M-Server and an L-PHY. This FHGW7-2->8 is connected to a group of O-RU8-1-1, O-RU8-1-N, and another FHGW7-1->8. The O-RU8-1-1 and O-RU8-1-N contain an M-Server and RU SW. The second FHGW7-1->8 contains an M-Server and an L-PHY. This second FHGW7-1->8 is connected to a group of O-RU8-2-1 and O-RU8-2-M, which also contain an M-Server and RU SW. Red dashed arrows represent NETCONF M-Plane Connections between M-Client and M-Servers. Solid blue lines represent Ethernet Links between O-DU7-2 and FHGW7-2->8, and between FHGW7-2->8 and the other FHGW7-1->8. Solid black lines represent CPRI Links between FHGW7-2->8 and the O-RU8-1 group, and between the second FHGW7-1->8 and the O-RU8-2 group. A legend on the right defines the symbols: red dashed arrow for NETCONF M-Plane Connection, blue line for Ethernet Link, black line for CPRI Link, blue box for H-PHY (High-PHY), light blue box for L-PHY (Low-PHY), orange box for M-Client (M-Plane Netconf Client), light orange box for M-Server (M-Plane Netconf Server), and grey box for RU SW (RU Software).](5cd221ed29927077aa6eb1df4b70341b_img.jpg) + +Figure 2 Architecture M-Plane connection diagram. The diagram shows a hierarchical network structure. At the top is O-DU7-2, which contains an M-Client and an H-PHY. Below it is FHGW7-2->8, which contains an M-Server and an L-PHY. This FHGW7-2->8 is connected to a group of O-RU8-1-1, O-RU8-1-N, and another FHGW7-1->8. The O-RU8-1-1 and O-RU8-1-N contain an M-Server and RU SW. The second FHGW7-1->8 contains an M-Server and an L-PHY. This second FHGW7-1->8 is connected to a group of O-RU8-2-1 and O-RU8-2-M, which also contain an M-Server and RU SW. Red dashed arrows represent NETCONF M-Plane Connections between M-Client and M-Servers. Solid blue lines represent Ethernet Links between O-DU7-2 and FHGW7-2->8, and between FHGW7-2->8 and the other FHGW7-1->8. Solid black lines represent CPRI Links between FHGW7-2->8 and the O-RU8-1 group, and between the second FHGW7-1->8 and the O-RU8-2 group. A legend on the right defines the symbols: red dashed arrow for NETCONF M-Plane Connection, blue line for Ethernet Link, black line for CPRI Link, blue box for H-PHY (High-PHY), light blue box for L-PHY (Low-PHY), orange box for M-Client (M-Plane Netconf Client), light orange box for M-Server (M-Plane Netconf Server), and grey box for RU SW (RU Software). + +Figure 2 Architecture M-Plane connection + +From C-Plane & U-Plane perspective, as shown in the figure below, this architecture model includes: + +- High-PHY is deployed in O-DU<sub>7-2</sub> +- Low-PHY is deployed in O-RU<sub>8</sub> +- The O-DU and FHGW<sub>7-2→8</sub> connect with e-CPRI protocol and split with Option7-2. +- The FHGW<sub>7-2→8</sub> and FHGW<sub>7-1→8</sub> connect with e-CPRI protocol and split with Option7-2. +- The FHGW<sub>7-2→8</sub> and O-RU<sub>8</sub> connect with CPRI protocol and split with Option8. + +![Figure 3 Architecture C&U-Plane connection diagram. The diagram shows a hierarchical network architecture. At the top is an O-DU7.2 block containing an M-Client and an H-PHY. Below it is an FHGW7.2->8 block containing an M-Server and an L-PHY. This FHGW block is connected to a series of O-RU blocks. The first set of O-RU blocks are labeled O-RU8-1-1, O-RU8-1-N, and O-RU8-2-1, O-RU8-2-M. Each O-RU block contains an M-Server and an L-PHY. The connections are as follows: A solid blue line (Ethernet Link) connects the O-DU7.2 to the top FHGW7.2->8. Dashed blue lines (eCPRI C&U connection) connect the top FHGW7.2->8 to each of the O-RU8-1 blocks and the O-RU8-2 blocks. Solid black lines (CPRI Link) connect the top FHGW7.2->8 to the O-RU8-1 blocks and the O-RU8-2 blocks. A legend on the right defines the symbols: NETCONF M-Plane Connection (dashed red line), Ethernet Link (solid blue line), CPRI Link (solid black line), eCPRI C&U connection (dashed blue line), CPRI U-Plane connection (dashed black line), H-PHY (High-PHY), L-PHY (Low-PHY), M-Client (M-Plane Netconf Client), M-Server (M-Plane Netconf Server), and RU Software (RU Software).](95284068e22805f4d70466a4874a652f_img.jpg) + +Figure 3 Architecture C&U-Plane connection diagram. The diagram shows a hierarchical network architecture. At the top is an O-DU7.2 block containing an M-Client and an H-PHY. Below it is an FHGW7.2->8 block containing an M-Server and an L-PHY. This FHGW block is connected to a series of O-RU blocks. The first set of O-RU blocks are labeled O-RU8-1-1, O-RU8-1-N, and O-RU8-2-1, O-RU8-2-M. Each O-RU block contains an M-Server and an L-PHY. The connections are as follows: A solid blue line (Ethernet Link) connects the O-DU7.2 to the top FHGW7.2->8. Dashed blue lines (eCPRI C&U connection) connect the top FHGW7.2->8 to each of the O-RU8-1 blocks and the O-RU8-2 blocks. Solid black lines (CPRI Link) connect the top FHGW7.2->8 to the O-RU8-1 blocks and the O-RU8-2 blocks. A legend on the right defines the symbols: NETCONF M-Plane Connection (dashed red line), Ethernet Link (solid blue line), CPRI Link (solid black line), eCPRI C&U connection (dashed blue line), CPRI U-Plane connection (dashed black line), H-PHY (High-PHY), L-PHY (Low-PHY), M-Client (M-Plane Netconf Client), M-Server (M-Plane Netconf Server), and RU Software (RU Software). + +Figure 3 Architecture C&U-Plane connection + +The content of this chapter includes the management of FHGW<sub>7.2→8</sub> in accordance with the description of the previous architecture model chapter + +## A4.5 Interface Management + +### A4.5.1 CPRI Interface Management + +The basic properties management of the CPRI interface are in the following section, while the details of U-Plane data flow and transceiver parameter acquisition are in the specification of section 4.3.1. + +#### A4.5.1.1 CPRI Interface YANG model + +Yang model: o-ran-interfaces-cpri.yang + +The basic properties management of CPRI Interface includes: + +- The configuration of CPRI protocol version +- The configuration of CPRI interface model +- The configuration of CPRI line speed rate +- The configuration of CPRI link coding parameter +- CPRI start pointer configuration of C-Plane and M-Plane +- read CPRI status + +To make it simple, there are some working assumption about the basic property's management: + +- 1) CPRI interface mode. It is agreed that the northward interface of CPRI link is the master port mode, and the southward interface is the slave port mode. For example, in the case of direct connection, O-DU or FHGW<sub>7-2→8</sub> southward CPRI interface is master port mode, O-RU<sub>8</sub> port is slave port mode; while in the case of cascading, the northward port at the level above the O-RU<sub>8</sub> cascade is configured with slave port mode, and the southward port at the level below the O-RU<sub>8</sub> concatenation is configured with master port mode. +- 2) CPRI physical layer is in state A when it is ready. To ensure that CPRI link can reach state B and is in physical layer synchronization state, CPRI port shall be configured as follows: + - a) CPRI line rate configuration is as follows: + +**Table 4 The configuration of CPRI line rate** + +| CPRI line bit rate [Mbit/s] | Z | X | W | Y | B | +|-----------------------------|----------------|----------------|---------------|------------------|----------------| +| 10137.6 | 0, 1, ..., 149 | 0, 1, ..., 255 | 0, 1, ..., 15 | 0, 1, 2, ..., 19 | 0, 1, ..., 159 | +| 12165.12 | | | | 0, 1, 2, ..., 23 | 0, 1, ..., 191 | +| 24330.24 | | | | 0, 1, 2, ..., 47 | 0, 1, ..., 383 | + +- b) IQ sampling bits width + +**Table 5 IQ sampling bits width** + +| Direction of link | Symbol for sample width | Range[bits] | +|-------------------|-------------------------|-------------------------------| +| Downlink | M | 16 | +| Downlink | M | 8(with compression algorithm) | +| Uplink | M' | 16 | +| Uplink | M' | 8(with compression algorithm) | + +- c) CPRI link coding + +1. Link encoding can be configured as: +2. 64B/66B +3. 64B/66B RS-FEC (optional) + +- d) CPRI protocol version + +In order to ensure that the CPRI master and slave ports enter the state C, both ends of the CPRI agreement shall use the CPRI protocol version No. 1. "Protocol Version" is defined in the chapter "L1 Inband Protocol" of the CPRI specification. + +Note: The difference between Protocol Version 1 and 2 is that when Protocol Version = 2, all data (except subchannel Ns = 0 control word BYTES #Z.X.Y Y<=1 and subchannel Ns = 2) need to add perturbation before linear encoding. With Protocol Version = 1, perturbation is not required. For simplicity, use the Protocol Version = 1 configuration. + +- 3) To ensure that the master and slave ports of CPRI enter the state D, the control and management channel conventions are configured as follows: + - a) the control management channel, namely Ethernet channel rate configuration is as follows: + +**Table6 Ethernet channel rate configuration** + +| CPRI line bit rate[Mbit/s] | Length of control word[bit] | Control word consisting of BYTES# | Minimum ethernet bit rate[Mbit/s](#Z.194.0=rr111111) | Maximum ethernet bit rate[Mbit/s](#Z.194.0=rr010100) | +|----------------------------|-----------------------------|-----------------------------------------------------------------------------------------------------------------------|------------------------------------------------------|------------------------------------------------------| +| 10137.6 | 128 | #Z.X.0,#Z.X.1,#Z.X.2,#Z.X.3,#Z.X.4,#Z.X.5,#Z.X.6,#Z.X.7,#Z.X.8,#Z.X.9,#Z.X.10,#Z.X.11,#Z.X.12,#Z.X.13,#Z.X.14,#Z.X.15 | 7.68 | 337.92 | +| 12165.12 | 128 | #Z.X.0,#Z.X.1,#Z.X.2,#Z.X.3,#Z.X.4,#Z.X.5,#Z.X.6,#Z.X.7,#Z.X.8,#Z.X.9,#Z.X.10,#Z.X.11,#Z.X.12,#Z.X.13,#Z.X.14,#Z.X.15 | 7.68 | 337.92 | +| 24330.24 | 128 | #Z.X.0,#Z.X.1,#Z.X.2,#Z.X.3,#Z.X.4,#Z.X.5,#Z.X.6,#Z.X.7,#Z.X.8,#Z.X.9,#Z.X.10,#Z.X.11,#Z.X.12,#Z.X.13,#Z.X.14,#Z.X.15 | 7.68 | 337.92 | + +b) CPRI C-Plane and M-Plane pointer, pointing to the starting location for fast control and management of Ethernet channels. The Ethernet Pointer is configured as 20 + +4) To ensure that the master and slave ports of CPRI enter state E and State F, the O-RU<sub>8</sub> slave port can use the established Ethernet control and management channel to execute the NETCONF Call Home procedure in Chapter 4. + +5) CPRI state conventions + +1) CPRI starting state + +A . Standby + +B . L1 Synchronization and Rate Negotiation + +C . Protocol Setup + +D . C&M Plane (L2+) Setup + +E . Interface and Vendor specific Negotiation + +F . Operation + +4. Based on the above CPRI startup states, the M-Plane defines quarriable CPRI startup states, including ENABLE and DISABLE. When the equipment at both ends of the CPRI link enters the F state, the startup state of CPRI is ENABLE state, and the startup state of CPRI is DISABLE state if it is in the A-E state. + +2) CPRI link status + +CPRI specification defines the following alarms : + +A . LOS + +B . LOF + +C . SDI + +D . RAI + +5. Based on the above CPRI link alarms, the quarriable CPRI link states, including NORMAL and ABNORMAL, are defined at the time of the alarms. If have alarm for the ABNORMAL, otherwise NORMAL. + +1 + +###### 2 A4.5.1.2 Initialization CPRI Interface + +##### 3 **Pre-condition:** + +4 The M-Plane connection between O-DU and FHGW<sub>7-2→8</sub> is established, and the FHGW<sub>7-2→8</sub> southward CPRI +5 interface initialization begins. + +##### 6 **Post-condition:** + +7 At the end of this procedure, the initialization configuration from the FHGW<sub>7-2→8</sub> southward to the CPRI interface +8 is completed. + +##### 9 **Procedure:** + +- 10 1) In the startup phase, according to the definition in the o-ran-interfaces-cpri.yang model, the NETCONF client +11 completed the initialization configuration of basic parameters such as line-bit-rate, sample width, Protocol +12 Version, Pointer P for each FHGW<sub>7-2→8</sub> southward CPRI interface. +- 13 2) During the link establishment procedure of CPRI, Protocol Version, Pointer P and other information are included +14 in the control word of CPRI and sent to O-RU<sub>8</sub>. + +##### 15 A4.5.1.3 Retrieve Transceiver information + +##### 16 **Pre-condition:** + +17 The M-Plane connection between O-DU and FHGW<sub>7-2→8</sub> is established. + +##### 18 **Post-condition:** + +19 At the end of this procedure, O-DU obtains the information of FHGW<sub>7-2→8</sub> transceiver module. + +##### 20 **Procedure:** + +- 21 1) During startup or hot plug, The FHGW<sub>7-2→8</sub> detects transceiver modules and stores data information +22 from transceiver modules in files; +- 23 2) The NETCONF client obtains the file according to the netconf-yang file upload procedure. +- 24 3) Exception: + - 25 ● If transceiver module is inserted during the file upload procedure, the contents of files before the +26 procedure or failure will be provided. + - 27 ● If FHGW<sub>7-2→8</sub> can not read data from transceiver module, or file does not exist, then FHGW<sub>7-2→8</sub> +28 does not create file or delete the file created before (note: Te file upload will failure because the +29 file does not exist during the file upload procedure.). + +##### 30 A4.5.1.4 Configuration CPRI Interface for U-Plane + +##### 31 **Pre-condition:** + +32 The M-Plane connection between O-DU and FHGW<sub>7-2→8</sub> is established. + +##### Post-condition: + +At the end of this procedure, the U-Plane from the FHGW<sub>7-2→8</sub> side is managed and configured. Configuration of the U-Plane data flow path between O-DU and FHGW<sub>7-2→8</sub> is completed. + +##### Procedure: + +- 1) The NETCONF client will configure and manage the U-Plane configuration of the FHGW<sub>7-2→8</sub> southward CPRI interface according to the newly added transport-flow type in the o-ran-processing-element.yang model. and set the transport-flow-type to "CPRI INTERFACE ", and carry out corresponding CPRI interface configuration of U-Plane. +- 2) eexc-id identifies the end-to-end data flow from the processing end of the O-DU to the end of the O-RU<sub>8</sub> antenna. Configure the data flow path between O-DU and FHGW<sub>7-2→8</sub> according to eexc information. +- 3) The FHGW<sub>7-2→8</sub> side completes the mapping from eexc to the FHGW<sub>7-2→8</sub> southward CPRI port. The specific CPRI interface IQ configuration information includes whether to compress IQ data, starting bit position of IQ data, starting bit position of compression information, AGC bit position etc. After completing the IQ configuration procedure of the CPRI interface, the CPRI mapping relationship on the southward CPRI interface is determined. In the case of different cell bandwidth and antenna configuration, different IQ configuration is required on the CPRI interface. + +## A4.6 FHGW<sub>7-2→8</sub> U-Plane Routing and Carrier Configuration + +The target of this chapter is similar to "Chapter 12 Details of O-RU<sub>8</sub> Operations" of [4]. + +U-Plane configuration in this chapter specifically refers to the U-Plane configuration of Option 7-2. Based on the architectural model in Chapter 2. Indoor Pico Cell have a Low PHY function (FFT/iFFT), as well as copy and combine functions, which U-Plane configuration described in this chapter. + +This chapter presents the configuration of U-Plane message routing between O-DU and FHGW<sub>7-2→8</sub>. After completing the U-Plane configuration, routing is established between the O-DU and the FHGW<sub>7-2→8</sub>'s U-Plane application endpoints, and IQ data can be exchanged using the U-Plane application protocol defined by [3]. + +The U-Plane message routing configuration includes: + +- 1) eexc-id address format definition +- 2) U-Plane endpoint addressing +- 3) U-Plane message routing configuration procedure + +### A4.6.1 General Description + +#### A4.6.1.1 YANG Model Files + +o-ran-uplane-conf-hub.yang: defining the U-Plane configuration capability of the FHGW<sub>7-2→8</sub> . + +#### A4.6.1.2 Specific Conventions + +Table 8 + +| | O-RAN M-plane Specification | This Specification | +|------------------------------|-----------------------------|--------------------| +| eAxC_ID subfield bit width | Not fixed | Fixed | +| Non-delay management service | supported | Not supported | + +#### A4.6.1.3 YANG Model Detail + +U-Plane configuration model is a user plane configuration of the Low PHY deployed in FHGW<sub>7-2→8</sub>. The YANG model is defined in o-ran-uplane-conf-hub.yang, which mainly includes: + +- ✓ List of multiple static TX endpoints: static-low-level-tx-endpoints +- ✓ List of multiple static RX endpoints: static-low-level-rx-endpoints +- ✓ List of multiple configurable TX endpoints: low-level-tx-endpoints. Each configurable TX endpoint low-level-tx-endpoint map to a static TX endpoint static-low-level-tx-endpoint. +- ✓ List of multiple configurable RX endpoints: low-level-rx-endpoints. Each configurable RX endpoint low-level-rx-endpoint map to a static RX endpoint static-low-level-rx-endpoint. +- ✓ List of multiple TX links: low-level-tx-links. Each low-level-tx-link, One end link e-CPRI data flow model eth-flow defined in the o-ran-processing-element.yang, the other end link to configurable TX endpoint low-level-tx-endpoint. +- ✓ List of multiple RX links: low-level-rx-links. Each RX link low-level-rx-link, one end link to e-CPRI data flow model eth-flow defined in the o-ran-processing-element.yang, the other end link to configurable TX endpoint low-level-rx-endpoint. + +![Figure 1 FHGW7-2-8 U-Plane Configuration. The diagram shows two main configuration blocks: 'north(eCPRI) transport configuration (o-ran-processing-element.yang)' and 'u-plane configuration (o-ran-uplane-conf-hub.yang)'. The north configuration block contains a 'processing-element (north-node)' which has fields for 'interface-name (north-eth-flow)', 'north-node-mac-address (north-node)', 'ru-mac-address (interface to north-node)', and 'vlan-id'. It is connected to a 'ietf-interface (type=l2vlan)' which is then connected to another 'ietf-interface (type=ethernetCsmacd)'. The u-plane configuration block contains 'low-level-tx-link' and 'low-level-rx-link' blocks, each with 'processing-element', 'tx-array-carrier', and 'low-level-tx/rx-endpoint' fields. These are connected to 'low-level-tx/rx-endpoint' blocks, which are in turn connected to 'static-low-level-tx/rx-endpoint' blocks. The diagram uses red boxes for nodes and red arrows for connections, with cardinalities like '1', 'n', and '0..n' indicating the number of instances.](4640181bc02a1c4ceabfe8f4c2d44e34_img.jpg) + +Figure 1 FHGW7-2-8 U-Plane Configuration. The diagram shows two main configuration blocks: 'north(eCPRI) transport configuration (o-ran-processing-element.yang)' and 'u-plane configuration (o-ran-uplane-conf-hub.yang)'. The north configuration block contains a 'processing-element (north-node)' which has fields for 'interface-name (north-eth-flow)', 'north-node-mac-address (north-node)', 'ru-mac-address (interface to north-node)', and 'vlan-id'. It is connected to a 'ietf-interface (type=l2vlan)' which is then connected to another 'ietf-interface (type=ethernetCsmacd)'. The u-plane configuration block contains 'low-level-tx-link' and 'low-level-rx-link' blocks, each with 'processing-element', 'tx-array-carrier', and 'low-level-tx/rx-endpoint' fields. These are connected to 'low-level-tx/rx-endpoint' blocks, which are in turn connected to 'static-low-level-tx/rx-endpoint' blocks. The diagram uses red boxes for nodes and red arrows for connections, with cardinalities like '1', 'n', and '0..n' indicating the number of instances. + +Figure 1 FHGW7-2-8 U-Plane Configuration + +### A4.6.2 Format of eAxC\_ID + +As defined in [3], eAxC\_ID consists of four parameters: DU-PORT, RU-PORT, CC-ID and BAND-SECTOR-ID. The sequence of parameters in eAxC\_ID must obey the CUS interface specification definition. + +In this specification, eAxC\_ID is 16 bit, Each subfield is configured with a fixed length: [DU-PORT]:[BAND-SECTOR]:[CCID]:[RU-PORT] = 2:6:4:4. + +<du-port-bitmask> 1100000000000000 </du-port-bitmask> + +<band-sector-bitmask> 0011111100000000 </band-sector-bitmask> + +<ccid-bitmask> 0000000011110000 </ccid-bitmask> + +<ru-port-bitmask> 0000000000001111 </ru-port-bitmask> + +### A4.6.3 U-Plane Endpoint Addressing + +For FHGW<sub>7-2→8</sub> based on e-CPRI Option7-2 to CPRI Option8, eexc-id is used for resource mapping and U-Plane endpoint addressing. + +Different eexc-id correspond to different logical functions, such as cell, carrier, air separation data flow, etc. It identifies the end-to-end data flow from the processing end of the O-DU to the end of the O-RU<sub>8</sub> antenna. + +During the configuration procedure: + +O-DU should configure the eexc-id for FHGW<sub>7-2→8</sub> U-Plane endpoints so as to realize the mapping between logical functions and FHGW<sub>7-2→8</sub> physical resources. Refer to the YANG model **low-level-tx-endpoint** and **low-level-rx-endpoint** in the o-ran-uplane-conf-hub.yang. + +O-DU should configure the relation between the U-Plane endpoint and the northward e-CPRI data flow for the FHGW<sub>7-2→8</sub>, to realize the mapping between the northward e-CPRI data flow and the O-RU<sub>8</sub> physical resources. + +O-DU should configure the relation between the U-Plane endpoint and the southward e-CPRI data flow for the FHGW<sub>7-2→8</sub>, to realize the mapping between the data flow to e-CPRI and the physical resources of O-RU<sub>8</sub>. See 15.2.4 shared cell for details. + +O-DU should configure the relation between the U-Plane endpoint and the southward CPRI data flow for the FHGW<sub>7-2→8</sub>, to realize the mapping between the southward CPRI data flow and the O-RU<sub>8</sub> physical resource. See 15.2.4 shared cell for details. + +In the procedure of data transmission, combined with the 15.2.1.1 CPRI U-Plane data flow model: + +In the downlink direction, the FHGW<sub>7-2→8</sub> obtains the e-CPRI data flow from the e-CPRI interface, finds the corresponding U-Plane Tx endpoint (**low-level-tx-endpoint**) according to eexc-id, and sends the processed data to the CPRI data flow on the corresponding CPRI interface. + +In the uplink direction, after the FHGW<sub>7-2→8</sub> receives the CPRI data flow from the CPRI interface, it finds the corresponding U-Plane Rx endpoint (**low-level-rx-endpoint**), according to eexc-id, and sends the processed data to the e-CPRI data flow on the corresponding e-CPRI interface. + +The rules for configuring eexc-id by O-DU are as follows: + +- For the same uplink U-Plane data flow, + - ✓ The low level TX endpoint (**low-level-tx-endpoint**) in FHGW<sub>7-2→8</sub> should be configured with the same eexc-id with TX endpoint (tx-endpoint) in O-RU<sub>8</sub>; +- For the same downlink U-Plane data flow, + - ✓ The low level RX endpoint (**low-level-rx-endpoint**) in FHGW<sub>7-2→8</sub> should be configured with the same eexc-id with the RX endpoint (rx-endpoint) in O-RU<sub>8</sub>; + +The FHGW<sub>7-2→8</sub> should reject configuration requests that violate the above rules. + +The diagram below shows an example of eaxc-id assignment in the architecture converting from eCPRI Option7 to CPRI Option8. + +![Figure 2: Examples of eaxc-id assignment. The diagram illustrates the architecture for converting from eCPRI Option7 to CPRI Option8. It shows an O-DUg connected to an FHGW7-2-8, which in turn connects to two cells: Cell #1 and Cell #2. Cell #1 contains O-RUg#1a and O-RUg#1b, while Cell #2 contains O-RUg#2a. Each RU contains multiple eAxC-ID endpoints. A legend on the left defines the symbols: a blue dot for 'Example', a checkmark for 'Cell#1 - 2T2R' and 'Cell#2 - 2T2R', and specific eAxC-ID#1-1, eAxC-ID#1-2, eAxC-ID#2-1, and eAxC-ID#2-2 for the endpoints. The legend also defines the line types: solid blue for eCPRI connection, solid black for CPRI Connection, green dashed for Downlink stream, and red dashed for Uplink stream. The endpoints are color-coded: green for low-level-tx-endpoint, red for low-level-rx-endpoint, light green for tx-endpoint, and light red for rx-endpoint.](8d64fd56117f88e7f6943150fc205752_img.jpg) + +Figure 2: Examples of eaxc-id assignment. The diagram illustrates the architecture for converting from eCPRI Option7 to CPRI Option8. It shows an O-DUg connected to an FHGW7-2-8, which in turn connects to two cells: Cell #1 and Cell #2. Cell #1 contains O-RUg#1a and O-RUg#1b, while Cell #2 contains O-RUg#2a. Each RU contains multiple eAxC-ID endpoints. A legend on the left defines the symbols: a blue dot for 'Example', a checkmark for 'Cell#1 - 2T2R' and 'Cell#2 - 2T2R', and specific eAxC-ID#1-1, eAxC-ID#1-2, eAxC-ID#2-1, and eAxC-ID#2-2 for the endpoints. The legend also defines the line types: solid blue for eCPRI connection, solid black for CPRI Connection, green dashed for Downlink stream, and red dashed for Uplink stream. The endpoints are color-coded: green for low-level-tx-endpoint, red for low-level-rx-endpoint, light green for tx-endpoint, and light red for rx-endpoint. + +Figure 2 Examples of eaxc-id assignment + +### A4.6.4 U-Plane Routing and Carrier Configuration + +The list YANG model of **low-level-tx-endpoints** and **low-level-rx-endpoints** in the o-ran-uplane-conf-hub.yang, represent the collection of FHGW<sub>7-2-8</sub> U-Plane endpoints. Each element of the list represents a TX endpoint or RX endpoint. The endpoint parameter (eaxc-id) represents the local address of the endpoint, It's an unsigned 16-bit integer, and follows the eaxc-id address format defined above. + +The NETCONF client is responsible for correlation all to the same interface, and a unique eaxc-id address assigned by the **low-level-rx-endpoint** element and the **low-level-tx-endpoint** element referenced by the **level-rx-link/the level-tx-link**. + +Note: + +- ✓ The **low-level-rx-endpoint** and the **low-level-tx-endpoint** can be assigned to the same eaxc-id. +- ✓ The NETCONF server should reject configuration requests that violate the above rules. +- ✓ The default eaxc-id parameter has a value of 0. + +#### Pre-condition: + +- The M-Plane connection between the NETCONF client and the NETCONF server is established. + +#### Post-condition: + +- Assign eaxc-id to the U-Plane transceiver endpoint. +- Carrier creation can be further performed. + +#### Procedure: + +- 1) The NETCONF client determines the following elements whether exist provided by the NETCONF server: + - **low-level-tx-endpoint** element: by reading o-ran-uplane-conf-hub.yang of the **static-low-level-tx-endpoints** list; + - **low-level-rx-endpoint** element: by reading o-ran-uplane-conf-hub.yang of the **static-low-level-rx-endpoints** list; + - **interface** elements: by reading o-ran-interfaces.yang **interface** list. +- 2) The NETCONF client determines the ability and parameters of O-RU<sub>s</sub> exposure through the following nodes: + - the **static-low-level-tx-endpoints** and the **static-low-level-rx-endpoints** exposed ability. + - the **endpoint-types** and the **endpoint-capacity-sharing-groups** exposed ability, + +##### Note 1 : + +- ✓ The information above shall be considered when the NETCONF client concatenates **low-level-t/rx-endpoints** (where the argument **name** points to **static-level-t/rx-endpoints**). + +- 3) For the elements identified in Step 1), the NETCONF client checks the following relationships: + - **static-low-level-tx-endpoint** element and **interface** element; + - **static-low-level-rx-endpoint** element and **interface** element. +- 4) For **static-low-level-rx-endpoint**, the NETCONF client determines its ability to support time-management-free and/or time-managed: + - The information of the delay service type supported by the endpoint is exposed through the parameter **delayed-data-transfer-supported** under **static-low-level-rx-endpoint**. and Supporting time management is a mandatory feature. + - Configure the non-time-managed-delay-enabled parameter of low-level-rx-endpoint. the default value of this parameter is FLASE, namely the endpoint support time management service by default. +- 5) The NETCONF client can optionally check the transmission connection of the NETCONF server, as described in Chapter 4.6 in [3]. + +##### Note 2: + +- ✓ After this step completes smoothly, the NETCONF client knows which NETCONF servers provide the **low-level-tx-endpoint** and **low-level-rx-endpoint elements** that the Tx/Rx endpoint of the NETCONF client service has access to. + +- 6) The NETCONF client determines accessible the **low-level-rx-endpoint** elements and the **low-level-tx-endpoint** elements, suitable for the target cell configuration (that is, connected to a specific antenna array and able to support the target business type). +- 7) The NETCONF client assigns an unique eaxc-id to the endpoint identified in Step 1). + +##### Note 3: + +- ✓ For all endpoints connected to the same **interface** element, the eaxc-id is enforced to be unique. and is associated with either the **lower-level-rx-endpoint element** or the **lower-level-tx-endpoint element**. + +![Sequence diagram showing the U-Plane configuration and carrier creation process between a NETCONF Server and a NETCONF Client. The process includes configuration steps, checks, and status reports.](665babd43f0387a3fecc1d0ca2e081a8_img.jpg) + +**The example of U-Plane configuration and carrier creation** + +``` + +sequenceDiagram + participant Server as NETCONF Server + participant Client as NETCONF Client + + Note over Server, Client: config U-Plane interface(eg. VLAN) with RPC edit-config +o-ran-interfaces:interface + Note over Server, Client: Use RPC get-config operation to query configuration data +o-ran-uplane-conf:tx-arrays +o-ran-uplane-conf:rx-arrays +o-ran-uplane-conf:static-low-level-tx-endpoints +o-ran-uplane-conf:static-low-level-rx-endpoints +o-ran-interfaces:interface + Note over Server, Client: Check the relationship between the following configuration data +static-low-level-tx-endpoint vs. tx-array +static-low-level-rx-endpoint vs. rx-array +static-low-level-tx-endpoint vs. interface +static-low-level-rx-endpoint vs. interface +tx-arrays vs. rx-arrays + opt + Note over Server, Client: check U-Plane link status + end + Note over Server, Client: Check that the following configuration data meets the configuration requirements of the customer unit +low-level-tx-endpoint +low-level-rx-endpoint + Note over Server, Client: Assign eaxc_id, and set each bit mask +o-du-port-bitmask +band-sector-bitmask +ccid-bitmask +ru-port-bitmask + Note over Server, Client: modify configuration using RPC edit-config +low-level-rx-endpoint.e-axcid +low-level-rx-endpoint.e-axcid + Note over Server, Client: U-Plane connect success + Note over Server, Client: number of tx-array-carriers = tx-arrays num * component carriers num +number of rx-array-carriers = rx-arrays num * component carriers num + Note over Server, Client: modify configuration using RPC edit-config +o-ran-uplane-conf:tx-array-carriers +o-ran-uplane-conf:rx-array-carriers +o-ran-uplane-conf:low-level-tx-links +o-ran-uplane-conf:low-level-rx-links +o-ran-processing-element:processing-elements + Note over Server, Client: Carrier created successfully + Note over Server, Client: modify configuration using RPC edit-config +o-ran-uplane-conf:tx-array-carrier.active = ACTIVE +o-ran-uplane-conf:rx-array-carrier.active = ACTIVE + Note over Server, Client: [1] Report carrier status tx-array-carrier.state == READY [notification] + Note over Server, Client: onAir + +``` + +The diagram illustrates the U-Plane configuration and carrier creation procedure between a NETCONF Server and a NETCONF Client. The process is as follows: + +- Configuration and Query:** + - Server sends `config U-Plane interface(eg. VLAN) with RPC edit-config` with `o-ran-interfaces:interface`. + - Server sends `Use RPC get-config operation to query configuration data` with `o-ran-uplane-conf:tx-arrays`, `o-ran-uplane-conf:rx-arrays`, `o-ran-uplane-conf:static-low-level-tx-endpoints`, `o-ran-uplane-conf:static-low-level-rx-endpoints`, and `o-ran-interfaces:interface`. + - Client checks the relationship between the following configuration data: + - static-low-level-tx-endpoint vs. tx-array + - static-low-level-rx-endpoint vs. rx-array + - static-low-level-tx-endpoint vs. interface + - static-low-level-rx-endpoint vs. interface + - tx-arrays vs. rx-arrays +- Optional Link Status Check:** + - Server sends `check U-Plane link status` (optional). +- Configuration Requirements and Assignment:** + - Client checks that the following configuration data meets the configuration requirements of the customer unit: + - low-level-tx-endpoint + - low-level-rx-endpoint + - Client assigns `eaxc_id` and sets each bit mask: + - `o-du-port-bitmask` + - `band-sector-bitmask` + - `ccid-bitmask` + - `ru-port-bitmask` +- Configuration Modification:** + - Server sends `modify configuration using RPC edit-config` with `low-level-rx-endpoint.e-axcid` and `low-level-rx-endpoint.e-axcid`. +- U-Plane Connect Success:** + - Client reports `U-Plane connect success`. + - Client calculates: + - `number of tx-array-carriers = tx-arrays num * component carriers num` + - `number of rx-array-carriers = rx-arrays num * component carriers num` +- Carrier Creation:** + - Server sends `modify configuration using RPC edit-config` with `o-ran-uplane-conf:tx-array-carriers`, `o-ran-uplane-conf:rx-array-carriers`, `o-ran-uplane-conf:low-level-tx-links`, `o-ran-uplane-conf:low-level-rx-links`, and `o-ran-processing-element:processing-elements`. + - Client reports `Carrier created successfully`. +- Carrier Activation:** + - Server sends `modify configuration using RPC edit-config` with `o-ran-uplane-conf:tx-array-carrier.active = ACTIVE` and `o-ran-uplane-conf:rx-array-carrier.active = ACTIVE`. +- Final Status Report:** + - Client reports `[1] Report carrier status tx-array-carrier.state == READY [notification]`. + - Server reports `onAir`. + +Sequence diagram showing the U-Plane configuration and carrier creation process between a NETCONF Server and a NETCONF Client. The process includes configuration steps, checks, and status reports. + + Figure 3 FHGW<sub>7.2→8</sub> U-Plane Configuration Procedure + +## A4.7 FHGW<sub>7-2→8</sub> Delay Management + +The fronthaul interface between O-DU and FHGW<sub>7-2→8</sub> adopts e-CPRI based on Option 7-2x function split defined by ORAN-WG4.CUS.0-v03.00. Its delay management complies with the technical requirements in Section 11.3, "Delay Management of shared Cell". + +### A4.7.1 Convention + +The current delay measurement and management model is implemented according to the FHGW<sub>7-2→8</sub> functional model given in Section 15.2.4. The functional model supports the following combine types: + +**Combine type1:** Uplink data from southward CPRI interfaces are combined in CPRI domain, after processed by the Low PHY and output in the format of Option7-2x at the FHGW<sub>7-2→8</sub> northward interface, namely uplink data of CPRI domain combined within the FHGW<sub>7-2→8</sub>. + +**Combine type 2:** Southward Option7-2x port (e-CPRI) Northward data can be combined in the 7-2x data domain. This mode is the FHM mode of O-RAN Option7-2x shared cell. This method supports the combine of 1~n sub-FHGW<sub>7-2→8</sub> uplinked data at the FHGW<sub>7-2→8</sub>. + +Corresponding to **Combine type 1**, the combine delay of Option8 field is reflected as a part of TBDelayUL. Corresponding to **Combine type 2**, the combine delay of option7-2x field is reflected as T\_Comb. + +##### Unsupported combines: + +Data combine between Option8 southward port and Option7-2X southward port is not currently supported. + +### A4.7.2 Delay Parameters + +Based on e-CPRI's definition of reference points, take the 2-level FHGW<sub>7-2→8</sub> cascade as an example, and the delay reference points are shown in the figure below. + +![Figure 4 Definition I of Time delay reference point and delay parameter. The diagram illustrates a 2-level FHGW cascade (FHGW#1 and FHGW#2) connected to an O-DU and an antenna. It shows various delay parameters and reference points. Key parameters include T_Copy, T_Comb, T1a, T2a, T3a, T4, T12_1, T12_2, T12_3, T34_1, T34_2, T34_3, T4a, TB2a, TBa3, and Toffset. Reference points are marked at the interfaces between O-DU, FHGW#1, FHGW#2, and the antenna. The diagram is divided into three sections: Option 7-2x, Option 7-2x, and Option 8.](9233f2b01da1c5adbefcdfca1b581b9b_img.jpg) + +Figure 4 Definition I of Time delay reference point and delay parameter. The diagram illustrates a 2-level FHGW cascade (FHGW#1 and FHGW#2) connected to an O-DU and an antenna. It shows various delay parameters and reference points. Key parameters include T\_Copy, T\_Comb, T1a, T2a, T3a, T4, T12\_1, T12\_2, T12\_3, T34\_1, T34\_2, T34\_3, T4a, TB2a, TBa3, and Toffset. Reference points are marked at the interfaces between O-DU, FHGW#1, FHGW#2, and the antenna. The diagram is divided into three sections: Option 7-2x, Option 7-2x, and Option 8. + +Figure 4 Definition I of Time delay reference point and delay parameter + +| N FHGW <sub>7-2→8</sub> cascades | symbols of figure | | Time delay parameter model | | Specification | +|--------------------------------------------------------------------------------------------------------------------|----------------------------|---------|-----------------------------------------------------|--------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | DL | UL | | +| e-CPRI network transmission delay<br>(For the NTH fronthaul connection, n=1...N) | T12_n<br>T34_n | | T12_n_min<br>T12_n_max | T34_n_min<br>T34_n_max | Configure parameters.<br>O-DU parameter acquisition method:<br>Method 1: Predefined<br>Method 2: Delay measurement<br>Notify O-RU <sub>8</sub> via M-Plane | +| O-DU TX/RX window | T1a<br>Ta4 | C Plane | T1a_min_cp_dl<br>T1a_max_cp_dl | T1a_min_cp_ul<br>T1a_max_cp_ul | Intermediate values.<br>According to the receive/send window of FHGW <sub>7-2→8</sub> and network transmission delay calculation | +| | | U Plane | T1a_min_up<br>T1a_max_up | Ta4_min<br>Ta4_max | | +| O-DU delay profile | NA | | T1a_max_up <sub>O-DU</sub><br>TXmax <sub>O-DU</sub> | Ta4_max <sub>O-DU</sub><br>RXmax <sub>O-DU</sub> | The capability parameter of O-DU. O-DU can be told to O-RU <sub>8</sub> via M-Plane | +| FHGW <sub>7-2→8</sub> #1 Copy/combine processing delay on southward cascade port | T_Copy<br>T_Comb | | T_Copy | T_Comb | Capability parameters (not configurable).<br>The FHGW <sub>7-2→8</sub> is reported to the O-DU via the M-Plane | +| | NA | | NA | Ta3_prime_max<br>T_Waiting | Configure parameters.<br>O-DU is configured to the FHGW <sub>7-2→8</sub> via the M-Plane | +| FHGW <sub>7-2→8</sub> #2 Processing delay on southward directly connected port FHGW <sub>7-2→8</sub> delay profile | TBDelayDL<br><br>TBDelayUL | C Plane | TBDelay_min_cp_dl<br>TBDelay_max_cp_dl | TBDelay_min_cp_ul<br>TBDelay_max_cp_ul | Capability parameters (not configurable).<br>Set values for bandwidth, subcarrier intervals, and ports<br>It may include:<br>The IQ data received from the northward interface in the cache is extracted to the Low PHY processing unit;<br>Low PHY treatment<br>Make a copy of the data to send to the southward interface | +| | | U Plane | TBDelay_min_up_dl<br>TBDelay_max_up_dl | TBDelay_min_up_ul<br>TBDelay_max_up_ul | | +| | NA | | Tcp_adv_dl | | Capability parameters (not configurable)<br>The descending C-Plane is relative to the advance of the -U-Plane<br>Make a copy of the data to send to the southward interface | +| FHGW <sub>7-2→8</sub> #2+O-RU <sub>8</sub> equivalent delay | TB2a<br>TBa3 | C Plane | TB2a_min_cp_dl<br>TB2a_max_cp_dl | TB2a_min_cp_ul<br>TB2a_max_cp_ul | Intermediate values. | + +| | | | | | | +|--|--|---------|----------------------------|----------------------|--| +| | | U Plane | TB2a_min_up<br>TB2a_max_up | TBa3_min<br>TBa3_max | | +|--|--|---------|----------------------------|----------------------|--| + +![Figure 5: Definition II of delay reference point and delay parameter. The diagram illustrates two network architectures, Option 7-2x and Option 8, showing the flow of data and the definition of various delay parameters. Option 7-2x shows a path from O-DU through FHW#1 and FHW#2, with delays T1a, TB2a, TBa3, and Ta4. Option 8 shows a similar path but with different delay components like T1'2_2, T1'4', and T2'a'. Red circles highlight specific delay points in both options.](127787227b746204380ba8de3eb11ecc_img.jpg) + +Figure 5: Definition II of delay reference point and delay parameter. The diagram illustrates two network architectures, Option 7-2x and Option 8, showing the flow of data and the definition of various delay parameters. Option 7-2x shows a path from O-DU through FHW#1 and FHW#2, with delays T1a, TB2a, TBa3, and Ta4. Option 8 shows a similar path but with different delay components like T1'2\_2, T1'4', and T2'a'. Red circles highlight specific delay points in both options. + +**Figure 5 Definition II of delay reference point and delay parameter** + +The time of delay in Option 7-2 fronthaul changes within a certain range, because of transmission changes in the packet switching network, includes : + +**Table 1 Delay Parameters** + +### A4.7.3 Relation of Delay Parameters + +**Table 2 Relation of delay parameters** + +| | | DL | UL | +|--------|---------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| CPRI | Optical fiber delay calculation | $T12\_3 = T34\_3 = (T14 - Toffset)/2$ | | +| e-CPRI | MSG5 delay measurement | $t_p = (t_2 - t_{cv2}) - (t_1 + t_{cv1})$ | | +| O-DU | TX/RX window calculation | $T1a\_max\_up \leq TB2a\_max\_up + T12\_min$<br>$T1a\_min\_up \geq TB2a\_min\_up + T12\_max$<br>$T1a\_max\_cp\_dl \leq TB2a\_max\_cp\_dl + T12\_min$<br>$T1a\_min\_cp\_dl \geq TB2a\_min\_cp\_dl + T12\_max$ | $Ta4min \leq TBa3min + T34min$<br>$Ta4max \geq TBa3max + T34max$<br>$T1a\_min\_cp\_ul \geq TB2a\_min\_cp\_ul + T12\_max$<br>$T1a\_max\_cp\_ul \leq TB2a\_max\_cp\_ul + T12\_min$ | +| O-DU | delay profile constraints | $T1a\_max\_up - T1a\_min\_up \geq TXmaxO\text{-}DU$<br>$T1a\_max\_upO\text{-}DU \geq T1a\_max\_up$ | $RXmaxO\text{-}DU \geq Ta4\_max - Ta4\_min$<br>$Ta4\_maxO\text{-}DU \geq Ta4\_max$ | +| Shared | cell | $T\_Copy < T\_Comb$ | | + +| | | +|---------------------------------------------------|----------------------| +| hypothesis | | +| Shared cell configuration parameter relationships | See section 3.14.4.4 | + +1 + +### A4.7.4 Timing Relations in Uplink and Downlink + +The following examples is figure of timing relationships of the U-Plane data transmission. + +#### A4.7.4.1 Timing Relations in Uplink + +![Figure 6: An example of uplink U-Plane (IQ) data timing. The diagram shows a timeline starting at t=0. It illustrates the flow of data from O-DU through FHGW#1 and FHGW#2 (Option7-2) to O-RU (Option8). Key timing parameters include Ta4_min, Ta4_max, T34_1_min, T34_1_max, T34_2_min, T34_2_max, T34_3, T_Comb, T3_prime_max, T_BDelay_min_up_ul, T_BDelay_max_up_ul, T_CPRI, and T_CPRI_IQ. The diagram also shows the Receive Window(UL) and Send Window(UL) for the O-DU and O-RU respectively.](87f58402589afd5db63f1e96c148f362_img.jpg) + +Figure 6: An example of uplink U-Plane (IQ) data timing. The diagram shows a timeline starting at t=0. It illustrates the flow of data from O-DU through FHGW#1 and FHGW#2 (Option7-2) to O-RU (Option8). Key timing parameters include Ta4\_min, Ta4\_max, T34\_1\_min, T34\_1\_max, T34\_2\_min, T34\_2\_max, T34\_3, T\_Comb, T3\_prime\_max, T\_BDelay\_min\_up\_ul, T\_BDelay\_max\_up\_ul, T\_CPRI, and T\_CPRI\_IQ. The diagram also shows the Receive Window(UL) and Send Window(UL) for the O-DU and O-RU respectively. + +5 + +**Figure 6 An example of uplink U-Plane (IQ) data timing** + +UL delay model parameters are shown in the figure above, and the conditions for the time series relationships to be established are as follows : + +**Condition 1: The introduction of a cascade of FHGW<sub>7-2→8</sub>s does not change the total delay between O-DU and O-RU<sub>8</sub>** + +Because the processing delay of uplink U-Plane message combining is added to the total prequel delay between O-DU and O-RU<sub>8</sub>, the distance between O-DU and O-RU<sub>8</sub> must be reduced in order to maintain the same delay between O-DU and O-RU<sub>8</sub> compared with the cascade node, so as to ensure that O-DU receives UL U-Plane messages in the O-DU receiving window. In other words, the prequel configuration should satisfy: + +$$T34\_max \geq T34\_1\_max + T\_Comb(\text{for FHGW}_{7-2 \rightarrow 8\#1}) + T34\_2\_max$$ + +Generalize to the case that there are N FHGW<sub>7-2→8</sub> cascading in the fronthaul network, + +$$\sum_{i=1}^N T34\_i\_max \leq T34\_max - \sum_{i=1}^{N-1} T\_Comb(\text{for } 0 - \text{Hub}\#i)$$ + +Among which : + +- T34\_n\_max is the maximum transmission delay between FHGW<sub>7-2→8#1</sub> and O-DU (n=1), and the maximum transmission delay between FHGW<sub>7-2→8#n</sub> and FHGW<sub>7-2→8#n-1</sub> (n=2..., N); +- T\_comb is the processing delay of FHGW<sub>7-2→8</sub> up-combine procedure, which depends on the capability of FHGW<sub>7-2→8</sub> and is reported through M-Plane. +- T34\_max is the maximum uplink transmission delay between O-DU and the final FHGW<sub>7-2→8</sub>. + +**Condition 2: UL U-Plane data sent by The FHGW<sub>7-2→8</sub> to the northward node for combining does not exceed Ta3\_prime\_max at the latest.** + +In order to ensure that O-DU receives UL U-Plane messages in the O-DU receiving window, the latest time that FHGW<sub>7-2→8#1</sub> can send to UL U-Plane messages combined with O-DU is "Ta4\_max-T34\_1\_max". Because T34\_1\_max depends on the location of FHGW<sub>7-2→8#1</sub>, you need to tell FHGW<sub>7-2→8#1</sub> the latest time to send. This time is defined as Ta3\_prime\_max, which needs to be configured to FHGW<sub>7-2→8#1</sub> through M-Plane, and satisfies: + +$$Ta3\_prime\_max(\text{for FHGW}_{7-2 \rightarrow 8\#1}) \leq Ta4\_max - T34\_1\_max$$ + +Generalize to the case that there are N FHGW<sub>7-2→8</sub> cascaded in the fronthaul network, + +$$Ta3\_prime\_max(\text{Cascading FHGW}_{7-2 \rightarrow 8\#n})$$ + +$$\leq Ta4\_max - \sum_{i=1}^n T34\_i\_max - \begin{cases} \sum_{i=1}^{n-1} T\_Comb(\text{for cascading FHGW}_{7-2 \rightarrow 8\#i}), & n \geq 2 \\ 0, & n = 1 \end{cases}$$ + +**Condition 3: The FHGW<sub>7-2→8</sub>'s wait time for combine processing should be greater than or equal to the time it receives all UL data** + +Consider T\_Comb, receiving UL U-Plane messages before "Ta3\_prime\_max-T\_comb" is limited to UL message combination. In other words, even if FHGW<sub>7-2→8#1</sub> did not receive all UL U-Plane messages before "Ta3\_prime\_max-t\_comb", FHGW<sub>7-2→8#1</sub> should combine any UL messages received and send them to O-DU before Ta3\_prime\_max. This time "Ta3\_prime\_max (configuration) -T\_comb (ability)" is defined as T\_Waiting and is counted in FHGW<sub>7-2→8#1</sub>. In order to combine all UL U-Plane messages, the configured Ta3\_prime\_max should meet the following criteria: + +$$T\_Waiting = Ta3\_prime\_max(\text{for FHGW}_{7-2 \rightarrow 8\#1}) - t\_comb(\text{for FHGW}_{7-2 \rightarrow 8\#1}) \geq T_{Ba3\_max} + T_{34\_2\_max}$$ + +Generalize to the case that there are N FHGW<sub>7-2→8</sub> cascading in the fronthaul network, + +$$T_{Ba3\_max} + \sum_{i=n+1}^N T34\_i\_max + \sum_{i=n}^{N-1} T\_Comb(\text{for FHGW}_{7-2 \rightarrow 8\#i}) \leq Ta3\_prime\_max(\text{for FHGW}_{7-2 \rightarrow 8\#n})$$ + +#### A4.7.4.2 Timing Relations in Downlink + +![Figure 7: Example of timing sequence of downlink U-Plane (IQ) data. The diagram shows the timing relationship between O-DU, FHGW#1, FHGW#2, and O-RU. It details the 'Option7-2' path for U-plane data and the 'Option8' path for CPRI IQ data. Key timing parameters include T12_max_up, T1a_min_up, T12_1_min, T12_1_max, T12_2_min, T12_2_max, T_Copy, T12_3, T2a+T_Cal_DL, and T_CPRI. The diagram also shows the 'Send window(DL)' and 'Receive Window(DL)' for the U-plane data.](1d81e313e553a20833e2a172352ca75c_img.jpg) + +Figure 7: Example of timing sequence of downlink U-Plane (IQ) data. The diagram shows the timing relationship between O-DU, FHGW#1, FHGW#2, and O-RU. It details the 'Option7-2' path for U-plane data and the 'Option8' path for CPRI IQ data. Key timing parameters include T12\_max\_up, T1a\_min\_up, T12\_1\_min, T12\_1\_max, T12\_2\_min, T12\_2\_max, T\_Copy, T12\_3, T2a+T\_Cal\_DL, and T\_CPRI. The diagram also shows the 'Send window(DL)' and 'Receive Window(DL)' for the U-plane data. + +**Figure 7 Example of timing sequence of downlink U-Plane (IQ) data** + +7. The DL temporal relationship as shown in the figure above is valid under the following conditions: + +**8. Condition 1: The maximum transmission delay of uplink and downlink is equal, namely,** + +$$9. T12\_max = T34\_max$$ + +$$10. T12\_i\_max = T34\_i\_max \quad (i=1 \sim N)$$ + +**11. Condition 2: $T\_Comb > T\_Copy$ , the uplink combine delay is greater than the downlink copy delay** + +Let's say that the UL combine is larger than the DL copy delay. Therefore, as long as the existing network and the group of the FHGW<sub>7-2→8</sub>#1 configuration meets the UL delay management requirements, the DL delay management of the shared cell does not require additional requirements, which is that the downlink data can be received in the receiving window of the FHGW<sub>7-2→8</sub>#2. Although DL does not need additional requirements, the O-DU knows that $T\_Copy$ is beneficial to the optimization of the O-DU fan window. Therefore, $T\_Copy$ is defined as the ability parameter of the FHGW<sub>7-2→8</sub>. + +### A4.7.5 Delay Management Procedure + +The procedure of delay management is shown in the figure below. + +![Figure 8 Delay management procedure sequence diagram showing interactions between O-DU, O-HUB#1, and O-HUB#2 across M Plane and CPRI domain.](957aab917b6f0dd92506b17f2c4f1ff4_img.jpg) + +The diagram illustrates the delay management procedure across four entities: O-DU, O-HUB#1, O-HUB#1, and O-HUB#1. The sequence of operations is as follows: + +- O-DU (NETCONF Client) sends:** + - Get HUB unit capability parameters (to O-HUB#1) + - Get HUB unit capability parameters (to O-HUB#1) + - Get RRU capability parameters (to O-HUB#1) + - Configure Total Delay (T\_CPRI) for CPRI (to O-HUB#1) + - Get HUB Delay Parameter T14 (to O-HUB#1) + - Calc T12\_3, T34\_3, T\_Cal\_DL/UL (local) + - Measure delay of eCPRI (to O-HUB#1) + - Measure delay of eCPRI (to O-HUB#1) + - Calc T12\_1, T12\_2, T34\_1, T34\_2 (local) + - Calc send and received Windows (local) + - Calc T3a\_prime\_max (local) + - Config Time Parameter T3a\_prime\_max (to O-HUB#1) + - Calc T\_waiting (local) + - Configure delay compensation value T\_Cal\_DL/T\_Cal\_UL (to O-HUB#1) +- O-HUB#1 (NETCONF Server) sends:** + - T\_Copy/Comb (to O-DU) + - TBDelayDL/UL (to O-DU) + - T\_Cal\_DL/UL\_max/Toffset/T2a/Ta3/N (to O-DU) + - Measure T14 of CPRI (to O-HUB#2) +- O-HUB#2 (NETCONF Server) sends:** + - Measure T14 of CPRI (to O-HUB#1) + +Additional labels on the left side of the diagram include: 国, 出, 家, 地, 发, 和, 對, alt [UP], 对, 發, ⑪, ⑫. + +Figure 8 Delay management procedure sequence diagram showing interactions between O-DU, O-HUB#1, and O-HUB#2 across M Plane and CPRI domain. + +Figure 8 Delay management procedure + +### A4.7.6 Key Points in CPRI Domain Delay Management + +CPRI domain uses a strict time delay adjustment approach and is less flexible than the window approach of e-CPRI domain. + +#### Downlink direction: + +Section 4.9 DL\_Offset parameter in Option8 O-RU<sub>8</sub> delay management model determines the "data/time" relationship at the FHGW<sub>7-2→8</sub> CPRI outlet. DL\_Offset, CPRI domain T12 of O-RU<sub>8</sub>, T\_Cal\_DL of O-RU<sub>8</sub>, T2a of O-RU<sub>8</sub>, these four parameters determine the occurrence of air port delay of downlink signals in an additive way. Under the current condition of indoor, DL\_Offset is required to have a certain margin because it involves the copy, summations and air port alignment between O-RU<sub>8</sub>, so that the increase or deletion of O-RU<sub>8</sub> in the same copy domain will not cause the delay adjustment of other O-RU<sub>8</sub> in the same cell. Specifically, the delay manager (O-DU) is required to reserve sufficient margin when constructing DL\_Offset. The implementation methods are as follows: + +- 1) Reserve enough delay amplification (such as adding the delay corresponding to X KM fiber by default in the indoor scene); +- 2) Increase the delay margin corresponding to x KM fiber based on the measurement and calculation of the first O-RU<sub>8</sub> found in topology; +- 3) Select the maximum delay range after finding all O-RU<sub>8</sub>; +- 4) The delay is adjusted when O-RU<sub>8</sub> is added and not adjusted when O-RU<sub>8</sub> is withdrawn, + +#### **Uplink direction:** + +The principle is similar to the downlink case, except that the T\_Cal\_UL setting only involves O-RU<sub>8</sub>. + +### **A4.7.7 YANG Model File** + +o-ran-delay-management-hub.yang + +o-ran-shared-cell.yang + +## **A4.8 FHGW<sub>7-2→8</sub> Shared Cell Configuration** + +### **A4.8.1 General Description** + +### **A4.8.2 YANG Model File** + +The FHGW<sub>7-2→8</sub> in the architecture of e-CPRI Option7-2 to CPRI Option8 needs to support two type of shared cell configurations at the same time: + +- FHGW<sub>7-2→8</sub> directly connected to O-RU<sub>8</sub> shared cell configuration +- FHGW<sub>7-2→8</sub> cascade FHGW<sub>7-2→8</sub> shared cell configuration + +![Figure 9: Example of shared cell data flow. The diagram illustrates a network architecture where a central FHGW_{7-2 \to 8} (High-Frequency Gateway) acts as a hub. It connects to an O-DU_{7-2} (Open Distributed Unit) at the top, which contains an M-Client and H-PHY. The FHGW_{7-2 \to 8} also contains an M-Server and L-PHY. Data flows from the O-DU_{7-2} to the FHGW_{7-2 \to 8} via eCPRI data links (Cell#1 Option7-2 eCPRI data and Cell#2 Option7-2 eCPRI data). The FHGW_{7-2 \to 8} then distributes data to multiple O-RU_{8} (Open Radio Units) via CPRI links. Specifically, it connects to O-RU_{8-1-1} through O-RU_{8-1-N} (Option8 CPRI IQ data) and to O-RU_{8-2-1} through O-RU_{8-2-M} (Cell#2 Option8 CPRI IQ data). A legend on the right defines the connection types: NETCONF M-Plane Connection (dashed red line), Ethernet Link (solid blue line), CPRI Link (solid black line), eCPRI C&U connection (dashed blue line), and CPRI U-Plane connection (dashed black line). It also defines the components: H-PHY (High-PHY), L-PHY (Low-PHY), M-Client (M-Plane Netconf Client), M-Server (M-Plane Netconf Server), and RU Software (RU Software).](5b04d21b726f67be23f7154274602105_img.jpg) + +Figure 9: Example of shared cell data flow. The diagram illustrates a network architecture where a central FHGW\_{7-2 \to 8} (High-Frequency Gateway) acts as a hub. It connects to an O-DU\_{7-2} (Open Distributed Unit) at the top, which contains an M-Client and H-PHY. The FHGW\_{7-2 \to 8} also contains an M-Server and L-PHY. Data flows from the O-DU\_{7-2} to the FHGW\_{7-2 \to 8} via eCPRI data links (Cell#1 Option7-2 eCPRI data and Cell#2 Option7-2 eCPRI data). The FHGW\_{7-2 \to 8} then distributes data to multiple O-RU\_{8} (Open Radio Units) via CPRI links. Specifically, it connects to O-RU\_{8-1-1} through O-RU\_{8-1-N} (Option8 CPRI IQ data) and to O-RU\_{8-2-1} through O-RU\_{8-2-M} (Cell#2 Option8 CPRI IQ data). A legend on the right defines the connection types: NETCONF M-Plane Connection (dashed red line), Ethernet Link (solid blue line), CPRI Link (solid black line), eCPRI C&U connection (dashed blue line), and CPRI U-Plane connection (dashed black line). It also defines the components: H-PHY (High-PHY), L-PHY (Low-PHY), M-Client (M-Plane Netconf Client), M-Server (M-Plane Netconf Server), and RU Software (RU Software). + +Figure 9 Example of shared cell data flow + +#### A4.8.2.1 Overview of FHGW<sub>7-2→8</sub> Connect to O-RU<sub>8</sub> + +In this specification, O-RU<sub>8</sub> under the same FHGW<sub>7-2→8</sub> can be configured for cell combination. In this configuration, the FHGW<sub>7-2→8</sub> shared cell information model consists of the following parts: + +- ✓ northward e-CPRI U-Plane interface +- ✓ U-Plane configuration, configure the Low PHY +- ✓ copy and combine FHGW<sub>7-2→8</sub> direct O-RU<sub>8</sub>, is used to configure radio unit via CPRI interface connection, and the radio unit combination constitutes the first share of data copy and combine the data model +- ✓ southward CPRI U-Plane interface + +![Figure 10: FHGW7-2→8 directly connecting O-RU8 Information. The diagram illustrates the configuration of a shared cell hub2ru (o-ran-shared-cell-cpri.yang) connecting to north(eCPRI) transport configuration (o-ran-processing-element.yang) and south(eCPRI) transport configuration (o-ran-processing-element-cpri.yang). The shared cell hub2ru contains shared-cell-copy-entities and shared-cell-combine-entities. The north(eCPRI) transport configuration includes a processing-element (north-node) with interface-name, north-eth-flow, north-node-mac-address, north-node, ru-mac-address, and vlan-id. It also includes a self-interface (type=l2vlan) and a self-interface (type=ethernetCsmacd). The south(eCPRI) transport configuration includes a processing-element-cpri (south-node) with element-name, interface-name, and AxCInformation. The diagram shows connections between low-level-bc-link, low-level-bc-endpoint, low-level-rx-link, and low-level-rx-endpoint across the different configurations.](a1fda3ddf979227cf665adb010b960f8_img.jpg) + +Figure 10: FHGW7-2→8 directly connecting O-RU8 Information. The diagram illustrates the configuration of a shared cell hub2ru (o-ran-shared-cell-cpri.yang) connecting to north(eCPRI) transport configuration (o-ran-processing-element.yang) and south(eCPRI) transport configuration (o-ran-processing-element-cpri.yang). The shared cell hub2ru contains shared-cell-copy-entities and shared-cell-combine-entities. The north(eCPRI) transport configuration includes a processing-element (north-node) with interface-name, north-eth-flow, north-node-mac-address, north-node, ru-mac-address, and vlan-id. It also includes a self-interface (type=l2vlan) and a self-interface (type=ethernetCsmacd). The south(eCPRI) transport configuration includes a processing-element-cpri (south-node) with element-name, interface-name, and AxCInformation. The diagram shows connections between low-level-bc-link, low-level-bc-endpoint, low-level-rx-link, and low-level-rx-endpoint across the different configurations. + +Figure 10 FHGW<sub>7-2→8</sub> directly connecting O-RU<sub>8</sub> Information + +#### A4.8.2.2 Overview of FHGW<sub>7-2→8</sub> Cascade to FHGW<sub>7-2→8</sub> + +In this specification, FHGW<sub>7-2→8</sub> cascading is supported. O-RU<sub>8</sub> under cascading FHGW<sub>7-2→8</sub>s and directly connected O-RU<sub>8</sub> at the same level are not required to be configured for cell combining. In this configuration, the shared cell information model includes the following parts: + +- ✓ northward e-CPRI U-Plane interface +- ✓ copy and combine of FHGW<sub>7-2→8</sub> cascade to FHGW<sub>7-2→8</sub> +- ✓ southward e-CPRI U-Plane interface + +![Figure 11: FHGW7-2-8 cascade to FHGW7-2-8 Information. The diagram shows three main components: 'north(eCPRI) transport configuration (o-ran-processing-element.yang)', 'shared cell hub2hub (forwarding only currently) (o-ran-shared-cell-cpri.yang)', and 'south(eCPRI) transport configuration (o-ran-processing-element.yang)'. The north component contains a 'processing-element (north-node)' which has an 'interface-name (north-eth-flow)' and optional fields for 'north-node-mac-address (north-node)', 'ru-mac-address (interface to north-node)', and 'vlan-id'. This connects to an 'ietf-interface (type=l2vlan)' which then connects to an 'ietf-interface (type=ethernetCsmacd)'. The shared cell hub2hub component contains 'shared-cell-copy-entities' (processing-elements for north-nodes and south-nodes) and 'shared-cell-combine-entities' (processing-elements for north-nodes and south-nodes). The south component contains a 'processing-element (south-node)' with an 'interface-name (north-eth-flow)' and optional fields for 'north-node-mac-address (north-node)', 'ru-mac-address (interface to north-node)', and 'vlan-id'. This connects to an 'ietf-interface (type=l2vlan)' which then connects to an 'ietf-interface (type=ethernetCsmacd)'. Arrows indicate the flow of information and dependencies between these components.](6c727b3eedb1f9a14e715ddcf4dfd31a_img.jpg) + +Figure 11: FHGW7-2-8 cascade to FHGW7-2-8 Information. The diagram shows three main components: 'north(eCPRI) transport configuration (o-ran-processing-element.yang)', 'shared cell hub2hub (forwarding only currently) (o-ran-shared-cell-cpri.yang)', and 'south(eCPRI) transport configuration (o-ran-processing-element.yang)'. The north component contains a 'processing-element (north-node)' which has an 'interface-name (north-eth-flow)' and optional fields for 'north-node-mac-address (north-node)', 'ru-mac-address (interface to north-node)', and 'vlan-id'. This connects to an 'ietf-interface (type=l2vlan)' which then connects to an 'ietf-interface (type=ethernetCsmacd)'. The shared cell hub2hub component contains 'shared-cell-copy-entities' (processing-elements for north-nodes and south-nodes) and 'shared-cell-combine-entities' (processing-elements for north-nodes and south-nodes). The south component contains a 'processing-element (south-node)' with an 'interface-name (north-eth-flow)' and optional fields for 'north-node-mac-address (north-node)', 'ru-mac-address (interface to north-node)', and 'vlan-id'. This connects to an 'ietf-interface (type=l2vlan)' which then connects to an 'ietf-interface (type=ethernetCsmacd)'. Arrows indicate the flow of information and dependencies between these components. + +Figure 11 FHGW<sub>7-2-8</sub> cascade to FHGW<sub>7-2-8</sub> Information + +#### A4.8.2.3 YANG Model of Northward e-CPRI U-Plane Interface + +The FHGW<sub>7-2-8</sub> northward U-Plane interface YANG model is based on Ethernet and e-CPRI, refer to Chapter 4 of O-RAN.WG4.MP.0-v03.00 + +#### A4.8.2.4 YANG Model of Southward e-CPRI U-Plane Interface + +The FHGW<sub>7-2-8</sub> southward cascading FHGW<sub>7-2-8</sub> U-Plane interface YANG model is based on Ethernet and e-CPRI, refer to Chapter 4 of O-RAN.WG4.MP.0-v03.00 + +#### A4.8.2.5 YANG Model of Southward CPRI U-Plane Interface + +The FHGW<sub>7-2-8</sub> southward CPRI U-Plane interface YANG model is based on CPRI, see 3.3.2 for details + +#### A4.8.2.6 YANG Model of U-Plane Configuration + +The U-Plane configuration of the FHGW<sub>7-2-8</sub> contains two parts. + +One is Low PHY U-Plane level configuration. In the architecture of this specification, the Low PHY is deployed in the FHGW<sub>7-2→8</sub> and the High PHY is deployed in the O-DU, so the U-Plane configuration of the Low PHY is required. Please see the details in 15.2.2.3. + +Another is shared cell U-Plane configuration. This part similar to the U-Plane configuration in the shared cell section of the O-RAN specification, which is mainly contains the configuration of U-Plane parameters such as eaxc-id related to downlink copy and uplink combine. + +To avoid misunderstanding, if not specifically mentioned, U-Plane configuration means Low PHY U-Plane configuration. + +#### A4.8.2.7 YANG Model of Shared Cell Configuration + +Two type of shared cell configurations: + +- Shared cell configuration of FHGW<sub>7-2→8</sub> connect to O-RU<sub>8</sub>, add a new YANG model file:o-ran-shared-cell-ecpri7-to-cpri8.yang +- Shared cell configuration of FHGW<sub>7-2→8</sub> cascade FHGW<sub>7-2→8</sub>, reuse the existing YANG mode file:o-ran-shared-cell.yang + +Each type of shared cell contains three parts: the parameters of shared cell capability, the parameters of shared cell downlink copy and the parameters of shared cell uplink combine. The following tables compare the main relations and differences between above two type of shared cell configuration with the option7-2 to Option7-2 FHM shared cell configuration in O-RAN specification. + +The parameters of shared cell capability, shared-cell-module-cap: + +**Table 3 Comparison of parameters of shared cell capability** + +| YANG model of shared cell in ORAN-WG4.MP.0-v03.00 | FHGW <sub>7-2→8</sub> cascade FHGW <sub>7-2→8</sub> in this Annex | FHGW <sub>7-2→8</sub> connect to O-RU <sub>8</sub> in this chapter | +|---------------------------------------------------|-------------------------------------------------------------------|--------------------------------------------------------------------| +| t-copy | reuse | Not needed. Reuse the TBDelay-*** in o-ran-delay-management.yang | +| t-combine | reuse | Not needed. Reuse the TBDelay-*** in o-ran-delay-management.yang | +| ta3-prime-max-upper-range | reuse | Not needed. The delay of CPRI fronthaul is consistent. | +| max-number-node-copy-and-combine | reuse | reuse | +| max-number-eaxcid-copy | reuse | reuse | +| max-number-eaxcid-combine | reuse | reuse | +| compression-method-supported | reuse | reuse | + +Share cell downlink copy parameters, shared-cell-copy-entities: + +**Table 4 Comparison of parameters of shared cell downlink copy** + +| YANG model of shared cell in ORAN-WG4.MP.0-v03.00 | FHGW <sub>7-2→8</sub> cascade FHGW <sub>7-2→8</sub> in this Annex | FHGW <sub>7-2→8</sub> connect to O-RU <sub>8</sub> in this chapter | +|---------------------------------------------------|-------------------------------------------------------------------|----------------------------------------------------------------------------------------| +| north-node-processing-element | reuse | low-level-tx-endpoint | +| south-node-processing-element | reuse, note 1 | south-node-processing-element-cpri | +| tx-eaxc-id | reuse | Necessary but no need to define, refer to the definition in o-ran-uplane-conf-hub.yang | +| rx-eaxc-id | reuse | No | +| downlink-radio-frame-offset | reuse | Necessary but no need to define, refer to the definition in o-ran-uplane-conf-hub.yang | +| downlink-sfn-offset | reuse | Necessary but no need to define, refer to the definition in o-ran-uplane-conf-hub.yang | + +Note 1: + +In the case that inter-stage RF combine is not supported, in the shared-cell-copy-entity of each copy rule, a northward node processes the element north-node-processing-element, and a southward node processes the element south-node-processing-element. + +Shared cell uplink combines parameters, shared-cell-combine-entities: + +**Table 5 Comparison of parameters of shared cell uplink combine** + +| YANG model of shared cell in ORAN-WG4.MP.0-v03.00 | FHGW <sub>7-2→8</sub> cascade FHGW <sub>7-2→8</sub> in this Annex | FHGW <sub>7-2→8</sub> connect to O-RU <sub>8</sub> in this chapter | +|---------------------------------------------------|-------------------------------------------------------------------|--------------------------------------------------------------------| +| north-node-processing-element | reuse | low-level-rx-endpoint | +| south-node-processing-element | reuse | south-node-processing-element-cpri | +| rx-eaxc-id | reuse | o-ran-uplane-conf-hub.yang | +| compression-format | reuse | reuse | +| ta3-prime-max | reuse | No | +| downlink-radio-frame-offset | reuse | o-ran-uplane-conf-hub.yang | +| downlink-sfn-offset | reuse | o-ran-uplane-conf-hub.yang | +| n-ta-offset | reuse | o-ran-uplane-conf-hub.yang | +| number-of-prb | reuse | No | + +### A4.8.3 Details of Operation + +This section describes the operation details of the shared cell. + +#### A4.8.3.1 Topology Discovery + +O-DU can obtain the O-RU<sub>8</sub> topological relation (adjacency relation) of a shared cell. The shared cell topology discovery procedure is filled in to the ethernet forwarding Information Base (FIB) using the LBM/LBR connection check procedure running at the Ethernet layer as defined in Section 3.3.1.5 Connectivity Detection, and FIB is obtained based on O-DU. The difference is that, since the FHGW<sub>7-2→8</sub> southward is based on CPRI IQ link, only the Ethernet network-based M-Plane has MAC address, therefore, the LBM/LBR procedure in the 3.3.1.5 Connectivity detection section, the FHGW<sub>7-2→8</sub> southward is based on M-Plane. Transparent bridge functionality is used for O-RU<sub>8</sub> with shared cell functionality running in FHGW<sub>7-2→8</sub> and/or cascading mode. + +O-DU determines the topology by the following two-step procedure : + +- 1) In the first phase, the procedure of using the 3.3.1.5 connectivity detection section is used to execute the Ethernet connection monitoring for all the discovered O-RU<sub>8</sub> MAC addresses. The echo of the Ethernet loopback from the found MAC address should ensure that the transparent bridge in the FHGW<sub>7-2→8</sub> and the cascading mode is automatically learning to pass the MAC addresses of these devices + +Note: In addition to Ethernet connection monitoring, DHCP discovery, Call Home and M-Plane connection establishment can also be used to fill in information in FIB, so maybe O-RU<sub>8</sub> has a northward port to do the above. + +- 2) In the second phase, O-DU uses the o-ran-ethernet-forwarding.yang model to discovery which MAC addresses have been learned by the ethernet bridge function. O-DU uses each Ethernet forwarding entry to determine adjacency relationships + +The following figure shows an example of the MAC address configuration of the FHGW<sub>7-2→8</sub> mode and the FHGW<sub>7-2→8</sub> operation pattern configuration, and the relevant transparent bridge fib table. + +![Figure 12 topology discovery diagram showing O-DU connected to O-RU#1 (Cascade Mode) and O-RU#FHM (FHM Mode).](027b35b317e9db756d297aa62bead3cb_img.jpg) + +The diagram illustrates the topology discovery of an O-RAN network. At the top, an **O-DU** block contains two interfaces: `mac-address/du#1` and `mac-address/du#2`. Below the O-DU, the network is divided into two main modes: **Cascade Mode** and **FHM Mode**. + +**Cascade Mode:** This mode shows a hierarchical structure of O-RUs. **O-RU#1 (shared-cell-capable)** is connected to `mac-address/du#1`. It contains a `if.mac-address/ru#1-1` interface and a **Bridge FIB Table** with entries: `port ru#1-1: du#1`, `port ru#1-2: ru#2-1`, and `port ru#1-2: ru#3-1`. Below O-RU#1 is **O-RU#2 (shared-cell-capable)**, which contains `if.mac-address/ru#2-1` and a **Bridge FIB Table** with entries: `port ru#2-1: du#1` and `port ru#2-2: ru#3-1`. Below O-RU#2 is **O-RU#3 (shared-cell-capable)**, which contains `if.mac-address/ru#3-1` and a **Bridge FIB Table** with entries: `port ru#3-1: du#1` and `port ru#3-2: <null>`. + +**FHM Mode:** This mode shows a flat structure of O-RUs. **O-RU#FHM (shared-cell-capable)** is connected to `mac-address/du#2`. It contains a `if.mac-address/ru#FHM0` interface and a **Bridge FIB Table** with entries: `port FHM0: du#2`, `port FHMa: ru#a`, `port FHMb: ru#b`, and `port FHMc: ru#c`. Below O-RU#FHM are three legacy O-RUs: **O-RU#A (legacy)** with `if.mac-address/ru#a`, **O-RU#B (legacy)** with `if.mac-address/ru#b`, and **O-RU#C (legacy)** with `if.mac-address/ru#c`. Each legacy O-RU is connected to a corresponding interface in O-RU#FHM: `if.mac-address/ru#FHMa`, `if.mac-address/ru#FHMb`, and `if.mac-address/ru#FHMc`. + +Figure 12 topology discovery diagram showing O-DU connected to O-RU#1 (Cascade Mode) and O-RU#FHM (FHM Mode). + +Figure 12 topology discovery + +#### A4.8.3.2 Configuration of Shared Cell + +The FHGW<sub>7-2→8</sub> needs to support two type of shared cell configurations. So does the downlink copy configuration. + +- Shared cell downlink configuration of FHGW<sub>7-2→8</sub> connect to O-RU<sub>8</sub> +- Shared cell downlink configuration of FHGW<sub>7-2→8</sub> cascade to FHGW<sub>7-2→8</sub> + +1 Examples are shown in the figure below + +![Figure 13: Shared cell downlink copy architecture diagram. The diagram shows a network topology starting from an 'Interface of northward eCPRI U-Plane' at the top. This interface connects to two paths: one leading to a 'U-Plane of Low PHY' and another leading to a 'shared cell downlink copy of FHGW cascade to FHGW'. The 'U-Plane of Low PHY' path leads to a 'shared cell downlink copy of FHGW connect to O-RU', which then branches into 'southward CPRI interface #1' and 'southward CPRI interface #N'. The 'shared cell downlink copy of FHGW cascade to FHGW' path branches into 'southward eCPRI interface #1' and 'southward eCPRI interface #N'. A legend on the left identifies three types of cells: 'Cell#1 option7-2 eCPRI Inform of U plane' (light blue), 'Cell#1 option8 CPRI Inform of U plane' (dark blue), and 'Cell#2 option7-2 eCPRI Inform of U plane' (brown). Small colored squares are placed along the connections to indicate which cell types are supported at each stage.](721cab6f12e01439a2fd0894510c5ab2_img.jpg) + +Figure 13: Shared cell downlink copy architecture diagram. The diagram shows a network topology starting from an 'Interface of northward eCPRI U-Plane' at the top. This interface connects to two paths: one leading to a 'U-Plane of Low PHY' and another leading to a 'shared cell downlink copy of FHGW cascade to FHGW'. The 'U-Plane of Low PHY' path leads to a 'shared cell downlink copy of FHGW connect to O-RU', which then branches into 'southward CPRI interface #1' and 'southward CPRI interface #N'. The 'shared cell downlink copy of FHGW cascade to FHGW' path branches into 'southward eCPRI interface #1' and 'southward eCPRI interface #N'. A legend on the left identifies three types of cells: 'Cell#1 option7-2 eCPRI Inform of U plane' (light blue), 'Cell#1 option8 CPRI Inform of U plane' (dark blue), and 'Cell#2 option7-2 eCPRI Inform of U plane' (brown). Small colored squares are placed along the connections to indicate which cell types are supported at each stage. + +Figure 13 Shared cell downlink copy + +5 The FHGW<sub>7-2→8</sub> needs to support two type of shared cell configurations. So does the uplink combine configuration. + +- 6 - Shared cell uplink combine configuration of FHGW<sub>7-2→8</sub> connect to O-RU<sub>8</sub> +- 7 - Shared cell uplink combine configuration of FHGW<sub>7-2→8</sub> cascade to FHGW<sub>7-2→8</sub> + +8 Examples are shown in the figure below + +![Figure 14 Shared cell uplink combine diagram. The diagram shows a network architecture for shared cell uplink combine. At the bottom, there are four southward interfaces: 'southward CPRI interface #1', 'southward CPRI interface #N', 'southward eCPRI interface #1', and 'southward eCPRI interface #N'. Above these, there are two 'shared cell uplink combine' blocks. The left block is labeled 'shared cell uplink combine of FHGW connect to O-RU' and the right block is labeled 'shared cell uplink combine of FHGW cascade to FHGW'. Both blocks connect to a 'U Plane of Low PHY' block. The 'U Plane of Low PHY' block connects to a 'northward eCPRI interface' block at the top. A legend on the left identifies three options: 'Cell#1 option7-2 eCPRI Inform of U plane' (blue box), 'Cell#1 option8 CPRI Inform of U plane' (dark blue box), and 'Cell#2 option7-2 eCPRI Inform of U plane' (brown box). Arrows indicate the flow of data from the southward interfaces through the shared cell uplink combine blocks and the U Plane of Low PHY to the northward eCPRI interface.](1c4406d96b3fdd345e71774056a6d456_img.jpg) + +Figure 14 Shared cell uplink combine diagram. The diagram shows a network architecture for shared cell uplink combine. At the bottom, there are four southward interfaces: 'southward CPRI interface #1', 'southward CPRI interface #N', 'southward eCPRI interface #1', and 'southward eCPRI interface #N'. Above these, there are two 'shared cell uplink combine' blocks. The left block is labeled 'shared cell uplink combine of FHGW connect to O-RU' and the right block is labeled 'shared cell uplink combine of FHGW cascade to FHGW'. Both blocks connect to a 'U Plane of Low PHY' block. The 'U Plane of Low PHY' block connects to a 'northward eCPRI interface' block at the top. A legend on the left identifies three options: 'Cell#1 option7-2 eCPRI Inform of U plane' (blue box), 'Cell#1 option8 CPRI Inform of U plane' (dark blue box), and 'Cell#2 option7-2 eCPRI Inform of U plane' (brown box). Arrows indicate the flow of data from the southward interfaces through the shared cell uplink combine blocks and the U Plane of Low PHY to the northward eCPRI interface. + +**Figure 14 Shared cell uplink combine** + +#### A4.8.3.3 Configuration of FHGW<sub>7-2→8</sub> Connect to O-RU<sub>8</sub> + +For the configuration of FHGW<sub>7-2→8</sub> connect to O-RU<sub>8</sub>, add a new YANG model file, o-ran-shared-cell-ecpri7-to-cpri8.yang, and eCPRI7-to-CPRI8 mode was added for the shared-cell-copy-combine mode in o-ran-shared-cell.yang, which is used for the configuration of FHGW<sub>7-2→8</sub> connect to O-RU<sub>8</sub>. + +- COMMON +- SELECTIVE +- eCPRI7-to-CPRI8 + +The function of downlink copy of shared-cell-copy-entities-ecpri7-to-cpri8 is configured in two parts. + +##### 1) low-level-tx-endpoint + +This parameter identifies the data source of the downlink copy of the shared cell, points to the Tx endpoint in the Low PHY U-Plane configuration. + +##### 2) south-node-processing-elements-cpri + +This parameter identifies the data destination of downlink copy of the shared cell, points to the CPRI flow, which is defined in the CPRI interface YANG model. + +The function of uplink combination of shared-cell-combine-entities-option8-cpri is configured in two parts + +1) low-level-rx-endpoint + +This parameter identifies the data destination of the shared cell uplink combine and points to the Rx endpoint in the Low PHY U-Plane configuration. + +2) south-node-processing-elements-cpri + +This parameter identifies the data source of the downlink copy data of the shared cell and points to the CPRI-Flow defined in the FHGW<sub>7-2→8</sub> southward CPRI interface model. + +Note: In contrast to the shared cell in O-RAN specification, the downlink copy and uplink combine configuration do not define the shared cell U-Plane configuration part. This is because all the U-Plane configuration information (such as eaxc-id, downlink-radio-frame-offset, downlink-sfn-offset, and N-TA-Offset of uplink only parameter) is fully defined in the low-level-tx-endpoint of Low PHY U-Plane configuration, and the shared cell part does not need to define it again. + +#### A4.8.3.4 Configuration of FHGW<sub>7-2→8</sub> Cascade to FHGW<sub>7-2→8</sub> + +For the configuration of **FHGW<sub>7-2→8</sub> cascade to FHGW<sub>7-2→8</sub>**, continue to reuse the COMMON mode of YANG model of shared-cell-copy-combine in the o-ran-shared-cell.yang. Which consistent with the configuration method of FHM shared cell in the O-RAN specification + +## A4.9 FHGW<sub>7-2→8</sub> Startup Example + +**Table 6 FHGW<sub>7-2→8</sub> Startup Procedure** + +| FHGW <sub>7-2→8</sub> Initialization Procedure | Description | Referred Sections | +|----------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------| +| Initialization of M-Plane network layer connection | Initialization of M-Plane network layer connection | Chapter 3.1 of [4] | +| Clock synchronization | Clock synchronization<br>The M-Plane connection has not been fully established at this stage, and clock synchronization should avoid to depend on configurable parameters, or should use default parameter. | Chapter 10 of [4] | +| M-Plane Call Home | M-Plane Call Home | Chapter 3.2 of [4] | +| Establishment of M-plane SSH connection | Establishment of management plane SSH connection | Chapter 3.3 of [4] | +| Retrieve NETCONF capability set of M-plane | Retrieve NETCONF capability set of M- plane | Chapter 3.5 of [4] | +| Keeping alive for M-Plane NETCONF connection | Keeping alive for M-Plane NETCONF connection | Chapter 3.6 of [4] | +| Retrieve the FHGW <sub>7-2→8</sub> parameters | Retrieve the FHGW <sub>7-2→8</sub> parameters | Chapter 6 of [4] | +| Software | Software management | Chapter 5 of [4] | + +| | | | +|-----------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------| +| management | | | +| clock synchronization | clock synchronization | Chapter 10 of [4] | +| CPRI interface initialization in FHGW <sub>7-2→8</sub> | CPRI interface initialization in FHGW <sub>7-2→8</sub> | A2.5 | +| Keeping alive for U-Plane connection | Keeping alive for U-Plane connection in FHGW <sub>7-2→8</sub> | Chapter 4.10 of [4] | +| Shared cell and U-Plane configuration | Topology discovery of FHGW <sub>7-2→8</sub><br>Read Delay Profile of FHGW <sub>7-2→8</sub><br>Northward e-CPRI interface configuration of FHGW <sub>7-2→8</sub><br>U-Plane configuration of FHGW <sub>7-2→8</sub><br>Shared cell configuration of FHGW <sub>7-2→8</sub> connect to O-RU <sub>8</sub><br>Shared Cell (optional) of FHGW <sub>7-2→8</sub> cascade to FHGW <sub>7-2→8</sub><br>Southward e-CPRI interface configuration of FHGW <sub>7-2→8</sub> (optional)<br>Southward CPRI interface configuration of FHGW <sub>7-2→8</sub> | A2.8 | +| Fault management initialization | Fault management initialization | Chapter 8 of [4] | +| Read status information of the FHGW <sub>7-2→8</sub> | Read status information of the FHGW <sub>7-2→8</sub> . | Chapter 6 of [4] | +| Configure runtime parameters of the FHGW <sub>7-2→8</sub> | Configure runtime parameters of the FHGW <sub>7-2→8</sub> | Chapter 6 of [4] | + +1 + +2 + +## A4.10 Appendix - YANG Model Tree Diagram + +3 + +This appendix lists YANG model tree diagrams that are newly defined or modified by this specification; refer to the O-RAN specification for other YANG models. + +4 + +5 + +### A4.10.1 o-ran-uplane-conf-hub Module + +6 + +``` +module: o-ran-uplane-conf-hub +``` + +7 + +``` + +-rw eaxc-id-group-configuration {mcap:EAXC-ID-GROUP-SUPPORTED}? +``` + +8 + +``` + | +-rw max-num-tx-eaxc-id-groups? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-tx-eaxc-id-groups +``` + +9 + +``` + | +-rw max-num-tx-eaxc-ids-per-group? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-tx-eaxc-ids-per-group +``` + +10 + +``` + | +-rw max-num-rx-eaxc-id-groups? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-rx-eaxc-id-groups +``` + +11 + +``` + | +-rw max-num-rx-eaxc-ids-per-group? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-rx-eaxc-ids-per-group +``` + +12 + +``` + | +-rw tx-eaxc-id-group* [representative-tx-eaxc-id] +``` + +13 + +``` + | | +-rw representative-tx-eaxc-id uint16 +``` + +14 + +``` + | | +-rw member-tx-eaxc-id* uint16 +``` + +``` + +1 | +-rw rx-eaxc-id-group* [representative-rx-eaxc-id] +2 | +-rw representative-rx-eaxc-id uint16 +3 | +-rw member-rx-eaxc-id* uint16 +4 +-rw user-plane-configuration +5 +-rw low-level-tx-links* [name] +6 +-rw name string +7 +-rw processing-element -> /o-ran-pe:processing-elements/ru-elements/name +8 +-rw low-level-tx-endpoint -> /user-plane-configuration/low-level-tx-endpoints/name +9 +-rw low-level-rx-links* [name] +10 +-rw name string +11 +-rw processing-element -> /o-ran-pe:processing-elements/ru-elements/name +12 +-rw low-level-rx-endpoint -> /user-plane-configuration/low-level-rx-endpoints/name +13 +-rw user-plane-uplink-marking? -> /o-ran-pe:processing-elements/enhanced-uplane-mapping/uplane-mapping/up-marking-name +14 +-ro endpoint-types* [id] +15 +-ro id uint16 +16 +-ro supported-section-types* [section-type] +17 +-ro section-type uint8 +18 +-ro supported-section-extensions* uint8 +19 +-ro supported-frame-structures* uint8 +20 +-ro managed-delay-support? enumeration +21 +-ro multiple-numerology-supported? boolean +22 +-ro max-numerology-change-duration? uint16 +23 +-ro max-control-sections-per-data-section? uint8 +24 +-ro max-sections-per-symbol? uint16 +25 +-ro max-sections-per-slot? uint16 +26 +-ro max-remasks-per-section-id? uint8 +27 +-ro max-beams-per-symbol? uint16 +28 +-ro max-beams-per-slot? uint16 + +``` + +``` + +1 | +-ro max-prb-per-symbol? uint16 +2 | +-ro prb-capacity-allocation-granularity* uint16 +3 | +-ro max-numerologies-per-symbol? uint16 +4 +-ro endpoint-capacity-sharing-groups* [id] +5 | +-ro id uint16 +6 | +-ro max-control-sections-per-data-section? uint8 +7 | +-ro max-sections-per-symbol? uint16 +8 | +-ro max-sections-per-slot? uint16 +9 | +-ro max-remasks-per-section-id? uint8 +10 | +-ro max-beams-per-symbol? uint16 +11 | +-ro max-beams-per-slot? uint16 +12 | +-ro max-prb-per-symbol? uint16 +13 | +-ro max-numerologies-per-symbol? uint16 +14 | +-ro max-endpoints? uint16 +15 | +-ro max-managed-delay-endpoints? uint16 +16 | +-ro max-non-managed-delay-endpoints? uint16 +17 +-ro endpoint-prach-group* [id] +18 | +-ro id uint16 +19 | +-ro supported-prach-preamble-formats* prach-preamble-format +20 +-ro static-low-level-tx-endpoints* [name] +21 | +-ro name string +22 | +-ro restricted-interfaces* -> /if:interfaces/interface/name +23 | +-ro endpoint-type? -> ../endpoint-types/id +24 | +-ro capacity-sharing-groups* -> ../endpoint-capacity-sharing-groups/id +25 +-ro static-low-level-rx-endpoints* [name] +26 | +-ro name string +27 | +-ro restricted-interfaces* -> /if:interfaces/interface/name +28 | +-ro endpoint-type? -> ../endpoint-types/id + +``` + +``` + +1 | +-ro capacity-sharing-groups* -> ../../endpoint-capacity-sharing-groups/id +2 | +-ro prach-group? -> ../../endpoint-prach-group/id +3 +-rw low-level-tx-endpoints* [name] +4 | +-rw name -> /user-plane-configuration/static-low-level-tx-endpoints/name +5 | +-rw compression! +6 | | +-rw iq-bitwidth? uint8 +7 | | +-rw compression-type enumeration +8 | | x--rw bitwidth? uint8 +9 | | +-rw (compression-format)? +10 | | +--:(no-compresison) +11 | | +--:(block-floating-point) +12 | | | +-rw exponent? uint8 +13 | | | +--:(block-floating-point-selective-re-sending) +14 | | | | +-rw sres-exponent? uint8 +15 | | | | +--:(block-scaling) +16 | | | | | +-rw block-scalar? uint8 +17 | | | | | +--:(u-law) +18 | | | | | | +-rw comp-bit-width? uint8 +19 | | | | | | +-rw comp-shift? uint8 +20 | | | | | | +--:(beam-space-compression) +21 | | | | | | | +-rw active-beam-space-coeficient-mask* uint8 +22 | | | | | | | | +-rw block-scaler? uint8 +23 | | | | | | | | +--:(modulation-compression) +24 | | | | | | | | | +-rw csf? uint8 +25 | | | | | | | | | | +-rw mod-comp-scaler? uint16 +26 | | | | | | | | | | +--:(modulation-compression-selective-re-sending) +27 | | | | | | | | | | | +-rw sres-csf? uint8 +28 | | | | | | | | | | | | +-rw sres-mod-comp-scaler? uint16 + +``` + +``` + +1 | +-rw frame-structure? uint8 +2 | +-rw cp-type? enumeration +3 | +-rw cp-length uint16 +4 | +-rw cp-length-other uint16 +5 | +-rw offset-to-absolute-frequency-center int32 +6 | +-rw number-of-prb-per-scs* [scs] +7 | | +-rw scs mcap:scs-config-type +8 | | +-rw number-of-prb uint16 +9 | +-rw e-axcid +10 | | +-rw o-du-port-bitmask uint16 +11 | | +-rw band-sector-bitmask uint16 +12 | | +-rw ccid-bitmask uint16 +13 | | +-rw ru-port-bitmask uint16 +14 | | +-rw eaxc-id uint16 +15 | +-rw downlink-radio-frame-offset uint32 +16 | +-rw downlink-sfn-offset int16 +17 +-rw low-level-rx-endpoints* [name] +18 | +-rw name -> /user-plane-configuration/static-low-level-rx-endpoints/name +19 | +-rw compression +20 | | +-rw iq-bitwidth? uint8 +21 | | +-rw compression-type enumeration +22 | | x-rw bitwidth? uint8 +23 | | +-rw (compression-format)? +24 | | +-:(no-compresison) +25 | | +-:(block-floating-point) +26 | | | +-rw exponent? uint8 +27 | | +-:(block-floating-point-selective-re-sending) +28 | | | +-rw sres-exponent? uint8 + +``` + +``` + +1 | | +--:(block-scaling) +2 | | | +--rw block-scalar? uint8 +3 | | +--:(u-law) +4 | | | +--rw comp-bit-width? uint8 +5 | | | +--rw comp-shift? uint8 +6 | | +--:(beam-space-compression) +7 | | | +--rw active-beam-space-coeficient-mask* uint8 +8 | | | +--rw block-scaler? uint8 +9 | | +--:(modulation-compression) +10 | | | +--rw csf? uint8 +11 | | | +--rw mod-comp-scaler? uint16 +12 | | +--:(modulation-compression-selective-re-sending) +13 | | | +--rw sres-csf? uint8 +14 | | | +--rw sres-mod-comp-scaler? uint16 +15 | | +--rw frame-structure? uint8 +16 | | +--rw cp-type? enumeration +17 | | +--rw cp-length uint16 +18 | | +--rw cp-length-other uint16 +19 | | +--rw offset-to-absolute-frequency-center int32 +20 | | +--rw number-of-prb-per-scs* [scs] +21 | | | +--rw scs mcap:scs-config-type +22 | | | +--rw number-of-prb uint16 +23 | | | +--rw ul-fft-sampling-offsets* [scs] +24 | | | | +--rw scs mcap:scs-config-type +25 | | | | +--rw ul-fft-sampling-offset? uint16 +26 | | | +--rw e-axcid +27 | | | +--rw o-du-port-bitmask uint16 +28 | | | +--rw band-sector-bitmask uint16 + +``` + +``` + +1 | | +-rw ccid-bitmask uint16 +2 | | +-rw ru-port-bitmask uint16 +3 | | +-rw eaxc-id uint16 +4 | +-rw non-time-managed-delay-enabled? boolean +5 | +-rw downlink-radio-frame-offset uint32 +6 | +-rw downlink-sfn-offset int16 +7 | +-rw n-ta-offset uint32 +8 +-rw general-config +9 +-rw regularization-factor-se-configured? boolean +10 +-rw little-endian-byte-order? boolean + +``` + +### A4.10.2 o-ran-shared-cell-ecpri7-to-cpri8 Module + +``` + +12 module: o-ran-shared-cell-ecpri7-to-cpri8 +13 +-rw shared-cell-cpri7-to-cpri8 +14 +-ro shared-cell-module-cap-ecpri7-to-cpri8 +15 | +-ro max-number-node-copy-and-combine uint8 +16 | +-ro max-number-eaxcid-copy uint8 +17 | +-ro max-number-eaxcid-combine uint8 +18 | +-ro compression-method-supported* [] {FHM-eCPRI7-to-CPRI8}? +19 +-rw shared-cell-config +20 +-rw (shared-cell-copy-combine-mode)? +21 +--:(COMMON) +22 | +-rw shared-cell-copy-entities* [name] +23 | | +-rw name string +24 | | +-rw north-node-processing-element? -> /o-ran-pe:processing-elements/ru-elements/name +25 | | +-rw south-node-processing-elements* -> /o-ran-pe:processing-elements/ru-elements/name +26 | | +-rw shared-cell-copy-uplane-config {FHM}? +27 | | +-rw tx-eaxc-id* [eaxc-id] + +``` + +``` + +| | | +--rw eaxc-id uint16 +| | +| | +--rw rx-eaxc-id* [eaxc-id] +| | +| | | +--rw eaxc-id uint16 +| | +| | +--rw downlink-radio-frame-offset uint32 +| | +| | +--rw downlink-sfn-offset int16 +| +| +--rw shared-cell-combine-entities* [name] +| +| +--rw name string +| +| +--rw north-node-processing-element? -> /o-ran-pe:processing-elements/ru-elements/name +| +| +--rw south-node-processing-elements* -> /o-ran-pe:processing-elements/ru-elements/name +| +| +--rw ta3-prime-max? uint32 +| +| +--rw shared-cell-combine-uplane-config {FHM}? +| +| +--rw rx-eaxc-id* [eaxc-id] +| +| | | +--rw eaxc-id uint16 +| +| | | +--rw compression-method +| +| | | +--rw iq-bitwidth? uint8 +| +| | | +--rw compression-type enumeration +| +| | | x--rw bitwidth? uint8 +| +| | | +--rw (compression-format)? +| +| | | +--:(no-compression) +| +| | | +--:(block-floating-point) +| +| | | | +--rw exponent? uint8 +| +| | | +--:(block-floating-point-selective-re-sending) +| +| | | | +--rw sres-exponent? uint8 +| +| | | +--:(block-scaling) +| +| | | | +--rw block-scalar? uint8 +| +| | | +--:(u-law) +| +| | | | +--rw comp-bit-width? uint8 +| +| | | | +--rw comp-shift? uint8 + +``` + +``` + + | | +--:(beam-space-compression) + | | | +--rw active-beam-space-coefficient-mask* uint8 + | | | +--rw block-scaler? uint8 + | | +--:(modulation-compression) + | | | +--rw csf? uint8 + | | | +--rw mod-comp-scaler? uint16 + | | +--:(modulation-compression-selective-re-sending) + | | +--rw sres-csf? uint8 + | | +--rw sres-mod-comp-scaler? uint16 + | +--rw downlink-radio-frame-offset uint32 + | +--rw downlink-sfn-offset int16 + | +--rw n-ta-offset uint32 + | +--rw number-of-prb uint16 + +--:(SELECTIVE) + +augment /sc:shared-cell/sc:shared-cell-config/sc:shared-cell-copy-combine-mode: + ++--:(eCPRI7-to-CPRI8) + + +--rw shared-cell-copy-entities-ecpri7-to-cpri8* [name] + | +--rw name string + | +--rw low-level-tx-endpoint? -> /uc-hub:user-plane-configuration/low-level-tx-endpoints/name + | +--rw south-node-processing-elements-cpri* -> /o-ran-pe:processing-elements/ru-elements/name + +--rw shared-cell-combine-entities-ecpri7-to-cpri8* [name] + +--rw name string + +--rw low-level-rx-endpoint? -> /uc-hub:user-plane-configuration/low-level-tx-endpoints/name + +--rw south-node-processing-elements-cpri* -> /o-ran-pe:processing-elements/ru-elements/name + +``` + +# --- Annex ZZZ: O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering + +any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter’s distributors and the use by the Adopter’s customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of ORAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the “Indemnitees”), against any liability, damage, loss, or expense (including reasonable attorneys’ fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter’s use of the licensed O-RAN Specifications or Adopter’s commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER’S BREACH OF SECTION 3, AND ADOPTER’S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED “AS IS” WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance’s sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/038c6ed5ad6cd46597b1d01007c21f71_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/038c6ed5ad6cd46597b1d01007c21f71_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b146bf8c46806e03d26f08c5f0867d3fcd9700f5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/038c6ed5ad6cd46597b1d01007c21f71_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5be6d41a47629f25a8e3378c103358ff822959e1e1b9d251dd54fc64ebfca530 +size 19961 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/06fff3f2835e01abaac189c199b21399_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/06fff3f2835e01abaac189c199b21399_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7f0a8d21c05ce69712ce1f8d87296fbdd581a905 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/06fff3f2835e01abaac189c199b21399_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:74837ca1a6c104c6cc0172ac9912c72aa3d83cd21983f8f936d0b27a9956299e +size 22586 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/08db15ca43cfcdd0dc32c059591d8fba_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/08db15ca43cfcdd0dc32c059591d8fba_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9dc54508c7d5cbadf9d5dfd61c96373512779239 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/08db15ca43cfcdd0dc32c059591d8fba_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b8c2ac5683f10182ab7d2a314727e37a8c9507f7a99c843cf99a28d8cf27da08 +size 20040 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/0c4d74ce2d50f4103d2aa3825ee796b6_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/0c4d74ce2d50f4103d2aa3825ee796b6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..43b432168e640c669e4f8c0a447634da63d9c014 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/0c4d74ce2d50f4103d2aa3825ee796b6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:44206209bf3aa4335c6094c0d213f1797fe925947e15f67f881aa0399b00f3ec +size 4437 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/13c0aa07902de223149e54b4cad73eab_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/13c0aa07902de223149e54b4cad73eab_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7f8af296c1db3230302b734fd78331cc047e0202 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/13c0aa07902de223149e54b4cad73eab_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3b042c78eb678836dc916c04de9400a8c3640b6c82fb41af9139def999a43335 +size 171417 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/14bc0dad6c5c508f6277428770af3625_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/14bc0dad6c5c508f6277428770af3625_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c93b14a7c6f68f7660ecb31a919ca100a1e1a776 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/14bc0dad6c5c508f6277428770af3625_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ddaa45cd89f5df60bd9b9278cea76a751246d014d136cd7fff4dff9eae12895a +size 39349 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/157004908c0c5923ae522e816182b74f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/157004908c0c5923ae522e816182b74f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..13d5758ee3e2ad6b4554193a1bc062a6c4f5a60f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/157004908c0c5923ae522e816182b74f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5041f68c16f813d6b985d3ecf0d2e0ed0b3ecc145e9a2aafe95d92700d8e063f +size 22641 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/17c52ff5b82f716452bde91f2df04c38_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/17c52ff5b82f716452bde91f2df04c38_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7d16194482dbcae4966c7e43fd6ae9576fb4dfc9 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/17c52ff5b82f716452bde91f2df04c38_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7a62a1381dc56ec90e42fd9e083634f3e30af727b9a9ea9030819cf640079dda +size 18603 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1a17affa0ba9cffa56658a0b886b5260_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1a17affa0ba9cffa56658a0b886b5260_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..182c097fdee6f3973802c09d0064644232761800 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1a17affa0ba9cffa56658a0b886b5260_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dabb8ccf07aa71accad343773ab9d2997dd59995ed4eb5ccd2a50cd03bd93392 +size 4630 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1a3aa71b2dda4f2097f306bf1d1b69c5_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1a3aa71b2dda4f2097f306bf1d1b69c5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6ae8b8e4a180c63eb5dc432e8049022da55963ea --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1a3aa71b2dda4f2097f306bf1d1b69c5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f975942bb6d978adc52948cb72cc051bdbb8d97906026aba108e29d7c363ef7e +size 59012 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1cbed3f91ba956e852eaabb5376daf87_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1cbed3f91ba956e852eaabb5376daf87_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..997532f2c33dc922e5db42b349be600877e0ba55 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1cbed3f91ba956e852eaabb5376daf87_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:82b6cfb4dbf295564dfe64effe907599e4c74e1e14423a6b463e3a427aa54e0e +size 53378 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1d3df773fc06ac88ddc2bb46dbac0090_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1d3df773fc06ac88ddc2bb46dbac0090_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..71752d63efd907c35b87c1979b12526d90fdef5a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1d3df773fc06ac88ddc2bb46dbac0090_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ee7874bf30ab24236facb4040178335946375af35897be0b1062565ffd0fd549 +size 55848 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1ef0ff9025b83cc61981c8fa3a0ac8b0_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1ef0ff9025b83cc61981c8fa3a0ac8b0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fe784c3c2e89bc68f692148ad9c817e379e5f734 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/1ef0ff9025b83cc61981c8fa3a0ac8b0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e7beed7d02bfbf9979e8d85a41af1f4f5f02e6e0ac5e22311bd7feffe00074e3 +size 4526 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2096a255a9fc7ea811043d3b539b259a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2096a255a9fc7ea811043d3b539b259a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7aab78f31ddafe3870edbcfd998d3fa1367e96c6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2096a255a9fc7ea811043d3b539b259a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:958707c11299261bff78afd3683d2faa6fbe3c015d1e16d52d00f577d77f0a01 +size 48217 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/26643e62c42de23c023b7be3d7106c3a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/26643e62c42de23c023b7be3d7106c3a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0262ae3ebf4eaee75d48637c1b17a7b845c5a481 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/26643e62c42de23c023b7be3d7106c3a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:23d38266156617764ef05f984a40459293a5dd87e81f49b8e2387ebcf1667948 +size 4549 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/298a18d32b2b587b644b0c8e93d2d8e8_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/298a18d32b2b587b644b0c8e93d2d8e8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a84991b0b65318fc8f03b12bbde491bfa759e330 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/298a18d32b2b587b644b0c8e93d2d8e8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a574e71092f6cd5d6c0b2eb0f65df3ead562c1cdb13f3874ab00acdfdaa48c8 +size 4541 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2992abc4ff8a63bbc59cabb3acbea7ce_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2992abc4ff8a63bbc59cabb3acbea7ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..886f4101195f2ea0fa1159318d0a10cefd95f929 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2992abc4ff8a63bbc59cabb3acbea7ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c32010d02795465102e83517c2ed01966ad81014e169660934973f14db82e12e +size 66565 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/29a2d139f009f5b5feaa9cd1192195a1_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/29a2d139f009f5b5feaa9cd1192195a1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2e94fd9404842ce2016c2f031af849b258c571b2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/29a2d139f009f5b5feaa9cd1192195a1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fe7d2f7da6f18fd243b04d72dd4d059c67ab3d17a3e08c6523204562f570b211 +size 45812 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2b27456baf618a836f786933758e062d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2b27456baf618a836f786933758e062d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d07044dfcaa3610593174c314e3df030ce81fa78 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2b27456baf618a836f786933758e062d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd1d879305042b063621da869c6bd568edab11d442d1b07470f02da5f0a68ebd +size 159532 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2f6e32049c7c308d5cfadfeb4ddcfd24_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2f6e32049c7c308d5cfadfeb4ddcfd24_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cf49cd4f9469b40823a6b703bad433276ba743fd --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/2f6e32049c7c308d5cfadfeb4ddcfd24_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84ea6ef1b094f9b257ac91a55f147517caccd4969fe080ed66f7000faa2aefe4 +size 13318 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3029b0b1ca7d9eabded25d7d283f6f21_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3029b0b1ca7d9eabded25d7d283f6f21_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5c52a4d1769ddefc2ab95b9d742689fc5a442b99 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3029b0b1ca7d9eabded25d7d283f6f21_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ffa9a03954d4ec9c08c1680a415bf46b8a2d0731e7a5ac30c7a864cc28a0913 +size 52235 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3490b7a94521a5e9a050c21ffd85df4a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3490b7a94521a5e9a050c21ffd85df4a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..83fe7c0b3ed4a5bdd9e5dbdf0911cbea25b1964f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3490b7a94521a5e9a050c21ffd85df4a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fe42a47a4ebda2ddac4e622f36edbd51b3c068e473ca30726995eb4d0566055c +size 105679 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/371a0270f778d956e7e1034ede54eb86_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/371a0270f778d956e7e1034ede54eb86_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..014a2f02b72c806b9a74ddec9caf868ef3277b55 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/371a0270f778d956e7e1034ede54eb86_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:830ead4362164f3e15961b0478a228e834d898d7f99abc33c79f2e721b9212c4 +size 19789 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/38840e43170a542e6bc3a28cbb086a42_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/38840e43170a542e6bc3a28cbb086a42_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..58df63ae38787348a8317ffa916adbbc95964cb6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/38840e43170a542e6bc3a28cbb086a42_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3f3619c53112df039636aee08a152b02a06558876abbc4efed9f65e4eec91bc2 +size 32910 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3b15cab8f4124ded2ba0b1da7ae45ed0_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3b15cab8f4124ded2ba0b1da7ae45ed0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cb73c834072653af48d1ced061e78406aab8932c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3b15cab8f4124ded2ba0b1da7ae45ed0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:55f9f4b6587d323ce972ad0d33f5c0c43097a8a9911122006718ddafb2ed4289 +size 49570 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3f79c6673e8f64183c5cdcca45f14109_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3f79c6673e8f64183c5cdcca45f14109_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5d32cd308e67acf3081e191bd9f12d69d5bce5b5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/3f79c6673e8f64183c5cdcca45f14109_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4ab22e5a1905ed8317f18fa77e778b65ac1b36d0e96ce3543c12af46905bf38a +size 84170 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/409c525aa7b6cb3c435b6e49d0c09006_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/409c525aa7b6cb3c435b6e49d0c09006_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..21fc35f4e3dd3015bbdd2ec814eb92fccd4637fa --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/409c525aa7b6cb3c435b6e49d0c09006_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b3ed0434eca18d4d4cb6ea80363f64c539d8d959effcc9d342d3254ee3188d3 +size 38023 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/42979da227339b730bfc23d4f02d6da7_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/42979da227339b730bfc23d4f02d6da7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b7c29651611a9a0003331e7f97b5220978bebab4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/42979da227339b730bfc23d4f02d6da7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b26a03ae1cf916cf47cdc64ab174e94211a08948fc3ed7a06684f0999f86f33f +size 132393 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/4433125b54c88c579c8ae01c15cb991a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/4433125b54c88c579c8ae01c15cb991a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a5660710d03568c0d0faf98940689433fbfaa9b7 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/4433125b54c88c579c8ae01c15cb991a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:74aa5f00c9e7f4f9dfb7b00b4c8c077331449fdd5cff196e9f375900e908ae5e +size 29162 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/44c65605d70e12adfc18d1f1f79bead3_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/44c65605d70e12adfc18d1f1f79bead3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3a621aefb150745eca4861bf2c84b77357997b35 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/44c65605d70e12adfc18d1f1f79bead3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d5a783f1ec1dfe5c281d69f3652132901012f41ddcf0fe16aa2c13b0ccb12a1 +size 88488 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/45064e087cd3448db002b0dd92ba166d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/45064e087cd3448db002b0dd92ba166d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9bcde5eb6a6399c262c5f40c39a1acda2314bbed --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/45064e087cd3448db002b0dd92ba166d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4e54f9a5ec098194f94c58d0a552b1b8c0fcb69f4094995e6839ba0bf13be3fb +size 4513 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/467e3a1c2953c2837cea9288ecb9b087_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/467e3a1c2953c2837cea9288ecb9b087_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b2badd0229cb40843bb2e0ee06b288c99ffa3f28 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/467e3a1c2953c2837cea9288ecb9b087_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:091ccb5daeab78fed60aa17f45c6e0896c59a13c1d61385e45f26c1a095cf73c +size 41823 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/48388a9455aead438d74cca6d831659d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/48388a9455aead438d74cca6d831659d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b428a2fd8db02b3b4bac137d570e61fbcecf8877 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/48388a9455aead438d74cca6d831659d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b68f061df93c88737db6191f75a3382e8445ca51a3bf078866666190da1b01f3 +size 31204 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/489596f747eaa98cebf35762bfc05306_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/489596f747eaa98cebf35762bfc05306_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f9ac943955b3a7cfca89500a0278fa381b4469be --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/489596f747eaa98cebf35762bfc05306_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d43a836bc1d26f09d695b30693d0f05e9d9b88f0b7761a6c06fa006a0d283c64 +size 71235 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/49223ffeaef46f815b5a4b0c47d7fd0b_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/49223ffeaef46f815b5a4b0c47d7fd0b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..49e50182b2b38253365214d0219c94808a5a0093 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/49223ffeaef46f815b5a4b0c47d7fd0b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3a592aa7d106bb60b5efbefdd179f77aa1b8e5bbb4980b65cb165c96adca5314 +size 42234 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/4a053f63b2da99d01eb4d4be8976f48c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/4a053f63b2da99d01eb4d4be8976f48c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3f542df0d2bb94d7a53f859869b1cd87629ab370 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/4a053f63b2da99d01eb4d4be8976f48c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c74bf94fa374ea462c7892469d4a63c3891b1acd546c244032f888a8ab269234 +size 28848 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5096848b75864ddba01ac0905c5d56cb_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5096848b75864ddba01ac0905c5d56cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f756eef8898883aaac46ab157662cab42d79edfe --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5096848b75864ddba01ac0905c5d56cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1016613ec13a8dcab0d0dc499ee17ba6600c20d67677f6077bcd3f8f4456290c +size 42307 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5b49732ac3493c30e6cd22c8e623ae54_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5b49732ac3493c30e6cd22c8e623ae54_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7ac9d163edc9395b51d2923edaddbdd874b7e87e --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5b49732ac3493c30e6cd22c8e623ae54_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:023ffee4455d913a8083c08bdaf9212dbf536eb94924aa2e089862c7d0c39da9 +size 4550 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5bfe35febb939a72e91d4570f34b807b_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5bfe35febb939a72e91d4570f34b807b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f5ba4aa0ad7a768847d24ae2f92be003873482a5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5bfe35febb939a72e91d4570f34b807b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:52219bb8b310de6897ef6f7bb5b67aa7686b5bb99d1391d49f751c9c26428795 +size 28260 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5d379ffcdf4ad708cb33813ed70a6bff_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5d379ffcdf4ad708cb33813ed70a6bff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd2ea75882d84a8df82757930a9b73fc3b29a486 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/5d379ffcdf4ad708cb33813ed70a6bff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:93436934681fd809e204a53e8961e9ea1372b067ced71ffeaffe240d80cebfa2 +size 66683 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/637220e540b05167ad430e16f60e67e0_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/637220e540b05167ad430e16f60e67e0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..218b66d0d8c6ce89076a1ff070993256c34de2df --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/637220e540b05167ad430e16f60e67e0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2879ecbe0f3d20e88d9d863fae9ab7850a3fa3daf92846af7acefbfbc5bccfa3 +size 4529 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/6b941cd502168634545a10be7aaf8fe8_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/6b941cd502168634545a10be7aaf8fe8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbaff73db5a03f2457cb63bf1802edc1892055d2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/6b941cd502168634545a10be7aaf8fe8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f48db0494d070391cc5eb875ab2b534d653f24489bc9ddf3ab5f768c2b0dbe07 +size 73155 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/79180f44ef0821b5dff7ecbd6f317b89_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/79180f44ef0821b5dff7ecbd6f317b89_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d0d36ad854944fa4a1f06ef69d7653a92d368432 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/79180f44ef0821b5dff7ecbd6f317b89_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:73fc1aafcb2f384341c75827af2560f90df1c945478c7a6f8d4c27e156f730c5 +size 70872 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/7caf956840f46865f405b843ab93a5ff_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/7caf956840f46865f405b843ab93a5ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c8c78ce64bd880ff87fea34dff34750993941aa1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/7caf956840f46865f405b843ab93a5ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:44ddb02a9b2eba84bc80277d3831aa69249417f2edd3a60f4187b2721b535b4d +size 20543 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/81dbfc8e237f251d95e60deef762f38d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/81dbfc8e237f251d95e60deef762f38d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8f1100aa9846dc44401dac081ed1caa9aa6c9956 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/81dbfc8e237f251d95e60deef762f38d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4f10401bea601ca725cf19fb890212a8173abb6d543d1058e8f7e1dbb0b93299 +size 17172 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/8947feeb3ee16e761b9a2dc6ea12edba_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/8947feeb3ee16e761b9a2dc6ea12edba_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4e083d4b2b3e8455ab33dd44cce18cfb35b517d6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/8947feeb3ee16e761b9a2dc6ea12edba_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b389984788c2647d449e77f7c2d206c395ae0f233a32922e528e406f3647cd07 +size 38329 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/8b933c4cfbd2947f5b0a60800f4abd19_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/8b933c4cfbd2947f5b0a60800f4abd19_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2e3663c0fb4f85881c66dc441a22763af359746c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/8b933c4cfbd2947f5b0a60800f4abd19_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2587a9e88ba611b94eebd66a17878aa2619e691640c9bd675fd71bdf98a491b4 +size 13899 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/8fed63f01ee5186e7b7f9cf4c271c46b_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/8fed63f01ee5186e7b7f9cf4c271c46b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..96e6fdb3a5621bac354de78757d7327cfae8516d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/8fed63f01ee5186e7b7f9cf4c271c46b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8bd0e6fe13340924107d7c1be7dc42102fd1e0953701d77a7b00d020076d7722 +size 29346 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/93dcc010dc08253f9f81a7ab476df6fe_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/93dcc010dc08253f9f81a7ab476df6fe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6ef7392a410c301a034cf1860f5a241450e88b79 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/93dcc010dc08253f9f81a7ab476df6fe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ad2af44a2530cdd4323f1658dfd1ce2bfa9ed39459a77b571ad840a7aa3c302a +size 49326 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/93f3be3f8a2e201d74b20d930ca972d2_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/93f3be3f8a2e201d74b20d930ca972d2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e7e15734c81785b4048d35242f28f3526546b114 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/93f3be3f8a2e201d74b20d930ca972d2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15265ed71056b9a1f90ddc966b7d6cfc41226f20510bb63c2e81902b5a2d53cd +size 21348 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/98987e5c6fe062006042b349fcd85a83_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/98987e5c6fe062006042b349fcd85a83_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b975c68fb238fc5c8a8f596c719672fd85920c9a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/98987e5c6fe062006042b349fcd85a83_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:39c348c139b9fc2ccaaecce6458f79188604f359fde554d0487aa900fb7465cb +size 80245 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/9b80aab779c011764acbd8d1da7ffa36_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/9b80aab779c011764acbd8d1da7ffa36_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..df3fed8b1da848865209cc8acbd5ddd6a911b651 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/9b80aab779c011764acbd8d1da7ffa36_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:eba58110b487235e3f4248ef8bbe6ca7d45a6ab6b75096b832cce8af70383a89 +size 54514 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/9cd3f945f7c87fad96ed812cbe810faa_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/9cd3f945f7c87fad96ed812cbe810faa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a5b47f4f2e2eedd7c37a7d821bd52b80442115e7 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/9cd3f945f7c87fad96ed812cbe810faa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8d5f5a9bc7707ee17551d31f7ffd0287eacf0e313f3c84bc9100ce9573118d6 +size 54138 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/9d20b971da9130ed33474cf2f74bfb3a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/9d20b971da9130ed33474cf2f74bfb3a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cd372e50bd44ab6b08da1792177fdd31b2437362 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/9d20b971da9130ed33474cf2f74bfb3a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:418220504222a36c1aa8e7b3ecdf731be98c8fb1194bb1e6fb1daa61cf5a5b0d +size 6206 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/a19d88441b0034abc63769b4b18a48c4_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/a19d88441b0034abc63769b4b18a48c4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..93d83dcbf809fdfc5e8b1bfcbe83ad608935ca82 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/a19d88441b0034abc63769b4b18a48c4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:038f8942904c663e26b819e2e60fa1e7121acd0071ec73c5718973de9351e1f5 +size 48169 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/a3d8cfa5128c9935be635924a7eb1298_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/a3d8cfa5128c9935be635924a7eb1298_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..acffcb89465402b3c180d73ac92ee2c7ec31e0a1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/a3d8cfa5128c9935be635924a7eb1298_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8a7b2a84186edb4ec81615709ec376afa14d3f300503f419c312204afcda6ce0 +size 10257 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/abd162c549e12557d1c0845637aba4bc_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/abd162c549e12557d1c0845637aba4bc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0c6a1037ae036a0d122ec393168f681737b9d7fe --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/abd162c549e12557d1c0845637aba4bc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4d59c857cd3fd451924efe29209a0b2df74231693d5036886739272701418e92 +size 54691 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/b0fc22b0386a60eb73f8892ef051dd19_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/b0fc22b0386a60eb73f8892ef051dd19_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9c10ca8cef6c3dc48058499c1d46400dd6366432 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/b0fc22b0386a60eb73f8892ef051dd19_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:82fab8043a7684f5b520a34b2c3b81f91216409d21588d78855aae7b5b60861d +size 64594 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/b50b0087e41ea5c72a2ccf7e1351b7c6_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/b50b0087e41ea5c72a2ccf7e1351b7c6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..54e55ac16ff3707c364c7d4548ee73029b9c5d3b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/b50b0087e41ea5c72a2ccf7e1351b7c6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4a56b221b5a5fa5464970eb7f842cf0c58cd0feeb9b05d970b509ba4a009e147 +size 57740 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/b883effb042684251cbba5d4e661b3a5_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/b883effb042684251cbba5d4e661b3a5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9ca20aa7fec66397dd863ee7c40cf4f77d052c5c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/b883effb042684251cbba5d4e661b3a5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:349e1176faf530a94d1c6e92dcde1d95337112ef7562f33a5dd327434846574f +size 67431 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/bd4a6d5c9ffe6ab2d8990a07e479b8d8_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/bd4a6d5c9ffe6ab2d8990a07e479b8d8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..848d74bef5c24fd997b4da05ca7d8106fb0bf320 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/bd4a6d5c9ffe6ab2d8990a07e479b8d8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64f1d14082edd4583f98b2b12a1a3aaa60e856e073e593bc1c05e6f7a1d7e595 +size 39856 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c04e9bcc95cc30242782e807df721353_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c04e9bcc95cc30242782e807df721353_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..696df0bc69f4d61efa99d66346dad1d64fa4af94 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c04e9bcc95cc30242782e807df721353_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aba7e09de43d652e6fb0bde767d5d7bbae97562a396d2ccd1ea9d96b421d2d4d +size 88209 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c7ed6171441f877ebbef0dd76c6cc794_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c7ed6171441f877ebbef0dd76c6cc794_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..72e7be986de034eae418b04b767a348df97cbac8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c7ed6171441f877ebbef0dd76c6cc794_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b5b47ae8ccd788d8ab8d845b0c05aed03fda63f30c8f33fad6e32a65545d3663 +size 4550 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c8ba1e5d78b448267736ac4960ad57bd_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c8ba1e5d78b448267736ac4960ad57bd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..332c2cff88df2240b4a2bc7072f28dec44fd8b9c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c8ba1e5d78b448267736ac4960ad57bd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48a635210ba8261b63677beba440f9d259a828fd3545008473c32e9d16f22a62 +size 99078 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c9ac5e0ed975c1f457839ba69e527b9c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c9ac5e0ed975c1f457839ba69e527b9c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a2790bb118d6bde3aeac64bb4abc23a07ec7b3a4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/c9ac5e0ed975c1f457839ba69e527b9c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dcd6d3b5891d67ea37b3e729e53b6f94b0ed232c7979fc8365fdad15c9235ee1 +size 48816 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ca1b46ac8e2c61302bb9aa7adc705ddd_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ca1b46ac8e2c61302bb9aa7adc705ddd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c1e6ada1de8f5e9c45314fd987af62c8171c94a6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ca1b46ac8e2c61302bb9aa7adc705ddd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b9e8e81b2fe04ef5d17f7a04ff735499306dad53e8685adc9a8fcf71eb7fc4fd +size 4545 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ca79a5cbc68b21d6446ba7caebcbc509_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ca79a5cbc68b21d6446ba7caebcbc509_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c84fa25f31cecb4e6ddd318598e2cae80859ad77 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ca79a5cbc68b21d6446ba7caebcbc509_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a610e49ab390d7a3b62292e17f1e9e3a6d10cdb889223e3fca4189b3332c04a4 +size 27301 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cc5f774bbeb8c9f900e5f07479a79229_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cc5f774bbeb8c9f900e5f07479a79229_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d6fa0398e44ba42903c81b2f04186926631812c2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cc5f774bbeb8c9f900e5f07479a79229_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fa58d76ec12d020ce70859720a5fee4bb27d11753284b13e2db3eb62dfee789e +size 61507 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cd38e1f836d5a3e2c14d9a448124647f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cd38e1f836d5a3e2c14d9a448124647f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1c1e1b1da5425b9ded7321f15b0d3f79bf0671e5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cd38e1f836d5a3e2c14d9a448124647f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:949f6e5337b03d08ce427323dd96bdd6728b0449c1306660afa8ab7975b25325 +size 4577 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cddc2fb37a8d84491bac1e594ff4f655_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cddc2fb37a8d84491bac1e594ff4f655_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3e0fc0cce3d5c4f27c9dbb08ab808c43d3112c93 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cddc2fb37a8d84491bac1e594ff4f655_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e208d7139fdb3ccb4e5bb535ab768ee53dd6918d175d09efb9deea1517cd936 +size 4567 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cddd4ef3dfe26eb59c7ca31dfc4644d9_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cddd4ef3dfe26eb59c7ca31dfc4644d9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ece7419255168fb3afaafd639f94772f2a4a3f98 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/cddd4ef3dfe26eb59c7ca31dfc4644d9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ae6281f945706c56c0dcd53ef94e8e8483d7f446c399249849f93f6a86f6f98b +size 31406 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ce4f8b5862c67a6b5b44ef5dc68f62ee_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ce4f8b5862c67a6b5b44ef5dc68f62ee_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ee70220511f029a0e629d9a2f4ba57d0f4fbafe2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ce4f8b5862c67a6b5b44ef5dc68f62ee_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1015a2b00fa78d22f57af48004d9bc27fac624f50a274fc9f5a73cb4b738ad40 +size 68831 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d08ee9467c8570a17fb6b3c1b67b23d3_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d08ee9467c8570a17fb6b3c1b67b23d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..46330eaed747c0e612a38585191dbd368e70276f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d08ee9467c8570a17fb6b3c1b67b23d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3b92f163757958dbbc027e2f2ac43ce732bdfc7f4a188aa49534c7f629c42ce9 +size 15457 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d12ff49842cb24abfdb68d334e00cbcc_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d12ff49842cb24abfdb68d334e00cbcc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..894e45634c67b90d9d2cc938722633ee5cfba6a1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d12ff49842cb24abfdb68d334e00cbcc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:07f68f24e2271a4f90126db09b7a8f5b90b263701e2590704e134e761fc876db +size 121223 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d13062ac292441952f96d0ec02908ab6_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d13062ac292441952f96d0ec02908ab6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2cef2efaefdfbe683be13a5a2cd469a55bb37a68 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d13062ac292441952f96d0ec02908ab6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:87d2ff009f6a5efce7dc89deab67ddf312271c1b1353ce76a4163d243f39d4c9 +size 4533 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d30b46386c6c863124083769c56c40de_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d30b46386c6c863124083769c56c40de_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9bb78cf442339da94d3cba878d54ce0d70fd4ce0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d30b46386c6c863124083769c56c40de_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d040c08b6e2e5d4a84732f2560f2b1d307fab1a3c5f12f1d04420dc32ad8ee0c +size 48796 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d50485084e8aa5ee57b0a9bf47f07cfc_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d50485084e8aa5ee57b0a9bf47f07cfc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9ab94a0a3ee1fde2dcbe3e925d0c8c98a763ecdc --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d50485084e8aa5ee57b0a9bf47f07cfc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f7e4314ca09df053f8336328b1859cbc0d4d33be41a788541feaac9a7b92decc +size 32073 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d805e80c8e5854328b68b9624d6cf92d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d805e80c8e5854328b68b9624d6cf92d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..99e44b9ca16aeaea578a24fc8aaebb35aefbc8d8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/d805e80c8e5854328b68b9624d6cf92d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8ec6a2a99213b6fce7e061b4d4ed048b2af0c718a767452d4b08c1a9b3b1b466 +size 58656 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/dbacf0cc890892d4d8b8a0cbd5b46c81_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/dbacf0cc890892d4d8b8a0cbd5b46c81_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ec66b5d666305bf6f3b037e67cd19aeb020dafce --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/dbacf0cc890892d4d8b8a0cbd5b46c81_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c3b3b018abcf7decf2ec65392e7f478afa259490053554f521fe80f4ec2b1c93 +size 4497 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/dee435732129f137d4ba86a903009297_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/dee435732129f137d4ba86a903009297_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..256fb6319906674b0dd755c955681770465570ee --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/dee435732129f137d4ba86a903009297_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:188faff7f53d4e33f169e7157c5902df08a122c4cd8e767ecea63b6d1660c0fe +size 20750 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/e44a1b669fba81691549d3002c95c724_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/e44a1b669fba81691549d3002c95c724_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..35706e9d4403c7b3678ec03816d73340b2372fc6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/e44a1b669fba81691549d3002c95c724_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84a923df8f749b82723eb155846671e1ee89a2d405120d6ace7c802c13e41f9c +size 24869 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/e8062f67aaf4d75b898bb8b69480ce2f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/e8062f67aaf4d75b898bb8b69480ce2f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..746134a20305375ad8f876a014f4f34714eb5ee8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/e8062f67aaf4d75b898bb8b69480ce2f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f9363bf9d360864b2398898569a5f7124e945e16b8a46a4ff5b6e1a6f1a7ea5e +size 66967 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ecb40e7ff5d500191d7e5cf88ae4866b_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ecb40e7ff5d500191d7e5cf88ae4866b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..acfa67fff21bd5499b455b6c83400febac35fe4c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ecb40e7ff5d500191d7e5cf88ae4866b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ede422c6e8b7024419e06dfd8b96182aa850055e402e1c11265594ea4f8749cc +size 4510 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ecbbe55f6b2adfb57320031f86d04c05_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ecbbe55f6b2adfb57320031f86d04c05_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7f29f586215a48ff4053ed0d7e09e16588f3cfc3 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ecbbe55f6b2adfb57320031f86d04c05_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f91c280560e72dd9a144ba230cbf6c0c5ee3fa9fe557866e90ed36592056774f +size 63075 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/f97ea381db3efcf9e8a321aee2d73918_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/f97ea381db3efcf9e8a321aee2d73918_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bb8576f4941019e6ed24a36156d9f93fb4ede5e8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/f97ea381db3efcf9e8a321aee2d73918_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bda624e2c7135bccebeb45472e8f14fcea6fa39e30a571d8b37abe4fab40c29c +size 30732 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ff2a28b810dfe861ccb6f9fb77db04b8_img.jpg b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ff2a28b810dfe861ccb6f9fb77db04b8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e94a936d881080bc4f51932f12dfad6b1d9000cc --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/ff2a28b810dfe861ccb6f9fb77db04b8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2e5daeb6e5f9c31522bbc16ff9acedd4941aa13cdcd1490209b6228492f28bbc +size 218446 diff --git a/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/raw.md b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..1aeef443609771be7b53cf69194358ac3692f992 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00/raw.md @@ -0,0 +1,5928 @@ + + +# O-RAN WG7 + +# Hardware Reference Design Specification for Indoor Picocell (FR1) with Split Architecture Option 8 --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# O-RAN WG7 + +## Hardware Reference Design Specification for Indoor Picocell (FR1) with Split Architecture Option 8 --- + +Copyright © 2021 by O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in the Annex *ZZZ* of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +1 + +# --- Revision History + +| Date | Revision | Author | Description | +|------------|----------|--------|-------------------------| +| 07/12/2021 | v03.00 | WG7 | Final Published Version | + +2 + +# Contents + +| | | +|------------------------------------------------------------------|----| +| Revision History..... | 2 | +| Chapter 1 Introductory Material ..... | 8 | +| 1.1 Scope ..... | 8 | +| 1.2 References ..... | 8 | +| 1.3 Definitions and Abbreviations..... | 9 | +| 1.3.1 Definitions..... | 9 | +| 1.3.2 Abbreviations..... | 9 | +| Chapter 2 Hardware Reference Design 1 ..... | 13 | +| 2.1 O-CU Hardware Reference Design ..... | 13 | +| 2.2 O-DU <sub>8</sub> Hardware Reference Design..... | 13 | +| 2.2.1 O-DU <sub>8</sub> High-Level Functional Block Diagram..... | 13 | +| 2.2.2 O-DU <sub>8</sub> Hardware Design Description..... | 14 | +| 2.2.3 O-DU <sub>8</sub> Hardware Components..... | 15 | +| 2.2.3.1 Digital Processing Unit..... | 15 | +| 2.2.3.2 Hardware Accelerator..... | 16 | +| 2.2.3.2.1 Accelerator Design Solution 1 ..... | 16 | +| 2.2.3.2.2 Accelerator Design Solution 2 ..... | 20 | +| 2.2.3.2.3 Accelerator Design Solution 3 ..... | 23 | +| 2.2.3.2.4 Accelerator Design Solution 4 ..... | 26 | +| 2.2.3.3 Baseboard Management Controller ..... | 27 | +| 2.2.4 Synchronization and Timing..... | 27 | +| 2.2.4.1 Synchronization and Timing Design 1 ..... | 27 | +| 2.2.4.2 Synchronization and Timing Design 2 ..... | 28 | +| 2.2.5 External Interface Ports..... | 29 | +| 2.2.6 O-DU <sub>8</sub> Firmware ..... | 30 | + +| | | | | +|----|-----------|-------------------------------------------------------------|----| +| 1 | 2.2.7 | Mechanical ..... | 31 | +| 2 | 2.2.8 | Power Unit ..... | 32 | +| 3 | 2.2.9 | Thermal ..... | 34 | +| 4 | 2.2.10 | Environmental and Regulations ..... | 34 | +| 5 | 2.3 | O-RU <sub>8</sub> Hardware Reference Design ..... | 35 | +| 6 | 2.3.1 | O-RU <sub>8</sub> High-Level Functional Block Diagram ..... | 35 | +| 7 | 2.3.2 | O-RU <sub>8</sub> Hardware Components ..... | 35 | +| 8 | 2.3.2.1 | Digital Processing Unit ..... | 37 | +| 9 | 2.3.2.2 | RF Processing Unit ..... | 40 | +| 10 | 2.3.2.2.1 | Transceiver Reference Design ..... | 40 | +| 11 | 2.3.2.2.2 | Power Amplifier (PA) Reference Design ..... | 46 | +| 12 | 2.3.2.2.3 | Low Noise Amplifier (LNA) Reference Design ..... | 48 | +| 13 | 2.3.2.2.4 | RF Switch Reference Design ..... | 50 | +| 14 | 2.3.2.2.5 | Antenna Reference Design ..... | 53 | +| 15 | 2.3.3 | Synchronization and Timing ..... | 53 | +| 16 | 2.3.4 | External Interface Ports ..... | 58 | +| 17 | 2.3.5 | Mechanical ..... | 59 | +| 18 | 2.3.6 | Power Unit ..... | 60 | +| 19 | 2.3.7 | Thermal ..... | 61 | +| 20 | 2.3.7.1 | Environmental and Regulations ..... | 61 | +| 21 | 2.4 | FHGW <sub>8</sub> Hardware Reference Design ..... | 62 | +| 22 | 2.5 | FHGW <sub>8</sub> High-Level Functional Block Diagram ..... | 62 | +| 23 | 2.6 | FHGW <sub>8</sub> Hardware Components ..... | 63 | +| 24 | 2.6.1 | Digital Processing Unit ..... | 63 | +| 25 | 2.6.2 | Synchronization and Timing ..... | 65 | +| 26 | 2.6.3 | External Interface Ports ..... | 66 | +| 27 | 2.6.4 | Mechanical ..... | 68 | + +| | | | | +|----|--------------------------------------------------------|--------------------------------------------------------------|-------------------------------------| +| 1 | 2.6.5 | Power ..... | 68 | +| 2 | 2.6.6 | Thermal ..... | 69 | +| 3 | 2.6.7 | Environmental and Regulations ..... | 69 | +| 4 | Annex 1 | Parts Reference List ..... | 70 | +| 5 | Annex 2 | CPRI specification reference design ..... | <b>Error! Bookmark not defined.</b> | +| 6 | Annex 3 | Option 8 CPRI spec reference design – Management plane ..... | 86 | +| 7 | Annex ZZZ | O-RAN Adopter License Agreement ..... | 179 | +| 8 | Section 1: DEFINITIONS ..... | | 179 | +| 9 | Section 2: COPYRIGHT LICENSE ..... | | 180 | +| 10 | Section 3: FRAND LICENSE ..... | | 180 | +| 11 | Section 4: TERM AND TERMINATION ..... | | 181 | +| 12 | Section 5: CONFIDENTIALITY ..... | | 181 | +| 13 | Section 6: INDEMNIFICATION ..... | | 181 | +| 14 | Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | | 181 | +| 15 | Section 8: ASSIGNMENT ..... | | 182 | +| 16 | Section 9: THIRD-PARTY BENEFICIARY RIGHTS ..... | | 182 | +| 17 | Section 10: BINDING ON AFFILIATES ..... | | 182 | +| 18 | Section 11: GENERAL ..... | | 182 | + +19 + +# 20 Tables + +| | | | +|----|------------------------------------------------------|----| +| 21 | Table 2-1: The Processor Feature List ..... | 15 | +| 22 | Table 2-2: The Memory Channel Feature List ..... | 15 | +| 23 | Table 2-3: Accelerator Hardware Component List ..... | 17 | +| 24 | Table 2-4: Accelerator Hardware Feature List ..... | 23 | +| 25 | Table 2-5: Accelerator Firmware Feature List ..... | 24 | +| 26 | Table 2-6: Accelerator Hardware Feature List ..... | 26 | +| 27 | Table 2-7: Accelerator Firmware Feature List ..... | 26 | +| 28 | Table 2-8: External Port List ..... | 29 | +| 29 | Table 2-9: Power supply unit feature list ..... | 34 | + +| | | | +|----|------------------------------------------------------------------------------|----| +| 1 | Table 2-10: Environmental Features..... | 34 | +| 2 | Table 2-11: Resource requirement for 2T2R O-RU <sub>8</sub> ..... | 37 | +| 3 | Table 2-12: Resource requirement for 4T4R O-RU <sub>8</sub> ..... | 37 | +| 4 | Table 2-13: Interface requirements of the Transceiver..... | 40 | +| 5 | Table 2-14: Payload with DPD in Digital Device (GBPS Rx/Tx)..... | 41 | +| 6 | Table 2-15: Payload with DPD in Transceiver (GBPS Rx/Tx) ..... | 41 | +| 7 | Table 2-16: RF specifications in Transceiver ..... | 42 | +| 8 | Table 2-17: PA Requirements ..... | 46 | +| 9 | Table 2-18: Interface requirements of the transmit PA..... | 47 | +| 10 | Table 2-19: One stage LNA Requirements..... | 48 | +| 11 | Table 2-20: Two stage LNA Requirements..... | 48 | +| 12 | Table 2-21: Interface requirements of the RF switch ..... | 50 | +| 13 | Table 2-22: RF Switch Requirements..... | 51 | +| 14 | Table 2-23: Antenna Requirements ..... | 53 | +| 15 | Table 2-24: Interface requirements of the clocking..... | 55 | +| 16 | Table 2-25: Clocking RF requirements ..... | 55 | +| 17 | Table 2-26: External Port List ..... | 58 | +| 18 | Table 2-27: Power unit requirement for 2T2R and 4T4R O-RU <sub>8</sub> ..... | 60 | +| 19 | Table 2-28: Power unit function ..... | 60 | +| 20 | Table 2-29: Environmental Features..... | 61 | +| 21 | Table 2-30: Interface requirements of the FPGA ..... | 63 | +| 22 | Table 2-31: FPGA Resource usage for FHGW <sub>8</sub> ..... | 64 | +| 23 | Table 2-32: Requirements of the PLL device..... | 65 | +| 24 | Table 2-33: External Port List ..... | 66 | +| 25 | Table 2-34: Requirements of the power unit ..... | 68 | + +26 + +# Figures + +| | | | +|----|-------------------------------------------------------------------------------------------|----| +| 28 | Figure 2-1: O-DU <sub>8</sub> Functional Block Diagram..... | 14 | +| 29 | Figure 2-2: O-DU <sub>8</sub> Hardware Block Diagram ..... | 15 | +| 30 | Figure 2-3: Example 2-chip FPGA-based Hardware Acceleration in O-DU <sub>8</sub> ..... | 19 | +| 31 | Figure 2-4: Example of 1-chip FPGA-based Hardware Acceleration in O-DU <sub>8</sub> ..... | 20 | +| 32 | Figure 2-5: Example of Accelerator Design ..... | 22 | +| 33 | Figure 2-6: Accelerator Design 1 without optional NIC Device ..... | 25 | +| 34 | Figure 2-7: Accelerator Design 1 with optional NIC Device ..... | 25 | +| 35 | Figure 2-8: Structured ASIC Accelerator Design..... | 26 | +| 36 | Figure 2-9: Structured ASIC Accelerator Design..... | 27 | +| 37 | Figure 2-10: O-DU <sub>8</sub> Timing Synchronization ..... | 28 | +| 38 | Figure 2-11: HW Acceleration Board Timing and Synchronization ..... | 29 | +| 39 | Figure 2-12: External interfaces reference design ..... | 30 | + +| | | | +|----|----------------------------------------------------------------------------------------------------|----| +| 1 | Figure 2-13: Mother Board Layout Diagram..... | 31 | +| 2 | Figure 2-14: Chassis Mechanical Diagram..... | 32 | +| 3 | Figure 2-15: High-Level Functional Block Diagram..... | 35 | +| 4 | Figure 2-16: 2T2R General Block Diagram with TR switch..... | 36 | +| 5 | Figure 2-17: 4T4R General Block Diagram with TR switch..... | 36 | +| 6 | Figure 2-18: Power estimation for 2T2R O-RU <sub>8</sub> ..... | 38 | +| 7 | Figure 2-19: Power estimation for 4T4R O-RU <sub>8</sub> ..... | 38 | +| 8 | Figure 2-20: FPGA Reference Design Diagram..... | 39 | +| 9 | Figure 2-21: Transceiver Reference Design Diagram (Optional elements are highlighted in Grey)..... | 45 | +| 10 | Figure 2-22: PA Reference Design Diagram..... | 47 | +| 11 | Figure 2-23: One Stage LNA Diagram..... | 49 | +| 12 | Figure 2-24: Two-Stage LNA Diagram..... | 50 | +| 13 | Figure 2-25: RF Switch Reference Design Diagram ..... | 52 | +| 14 | Figure 2-26: Whip Antenna ..... | 53 | +| 15 | Figure 2-27: PLL Reference Design Diagram..... | 57 | +| 16 | Figure 2-28: SFP+ case and connector ..... | 58 | +| 17 | Figure 2-29: RJ45 interface ..... | 59 | +| 18 | Figure 2-30: O-RU <sub>8</sub> Shell Mechanical Diagram..... | 59 | +| 19 | Figure 2-31: POE Reference Design Diagram..... | 61 | +| 20 | Figure 2-32: FHM <sub>8</sub> General Block Diagram ..... | 62 | +| 21 | Figure 2-33: FHM <sub>8</sub> Digital Processing Block Diagram..... | 64 | +| 22 | Figure 2-34: CLK reference design for FHM <sub>8</sub> ..... | 65 | +| 23 | Figure 2-35: SFP+ case and connector ..... | 66 | +| 24 | Figure 2-36: RJ45 interface ..... | 67 | +| 25 | Figure 2-37: AC power interface..... | 67 | +| 26 | Figure 2-38: Shell Mechanical Diagram..... | 68 | +| 27 | | | + +# Chapter 1 Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG7 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. This variable is for internal WG7 use only. + +The present document specifies system requirements and high-level architecture for the FR1 Picocell Indoor deployment scenario as specified in the Deployment Scenarios and Base Station Classes document [1]. + +In the main body of this specification (in any “chapter”) the information contained therein is informative, unless explicitly described as normative. Information contained in an “Annex” to this specification is always informative unless otherwise marked as normative. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- [1] ORAN-WG7.DSC.0-V01.00 Technical Specification, ‘Deployment Scenarios and Base Station Classes for White Box Hardware’. <https://www.o-ran.org/specifications> +- [2] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [3] 3GPP TR 38.104: "NR; Base Station (BS) radio transmission and reception". +[http://www.3gpp.org/ftp//Specs/archive/38\\_series/38.104/38104-g10.zip](http://www.3gpp.org/ftp//Specs/archive/38_series/38.104/38104-g10.zip) +- [4] ORAN-WG4.CUS.0-v03.00 Technical Specification, ‘O-RAN Fronthaul Working Group Control, User and Synchronization Plane Specification’. <https://www.o-ran.org/specifications> +- [5] 3GPP TS 38.113: "NR: Base Station (BS) Electromagnetic Compatibility (EMC)". +[http://www.3gpp.org/ftp//Specs/archive/38\\_series/38.113/38113-f80.zip](http://www.3gpp.org/ftp//Specs/archive/38_series/38.113/38113-f80.zip) +- [6] ORAN-WG7. IPC. HAR-v01.00 Technical Specification, ‘Indoor Pico Cell Hardware Architecture and Requirement Specification’. <https://www.o-ran.org/specifications>. + +[7] ORAN.WG7. IPC-HRD-Opt7-2.0-v03.00 Technical Specification, ‘Indoor Pico Cell BS Hardware Reference Design Specifications with Fronthaul Split Option 7-2 and FR1’. <https://www.o-ran.org/specifications> + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [2]. For the base station classes of Pico, Micro and Macro, the definitions are given in 3GPP TR 38.104 [3]. + +**Carrier Frequency:** Center frequency of the cell. + +**F1 interface:** The open interface between O-CU and O-DU<sub>8</sub> as defined by 3GPP TS 38.473 between CU and DU. + +**Integrated architecture:** In the integrated architecture, the O-RU and O-DU<sub>x</sub> are implemented on one platform. Each O-RU and RF front end is associated with one O-DU<sub>8</sub>. They are then aggregated to O-CU and connected by F1 interface. + +**Split architecture:** The O-RU<sub>x</sub> and O-DU<sub>x</sub> are physically separated from one another in this architecture. A switch may aggregate multiple O-RU<sub>s</sub> to one O-DU<sub>x</sub>. O-DU<sub>x</sub> switch and O-RU<sub>s</sub> are connected by the fronthaul interface as defined in WG4. + +**Transmission Reception Point (TRxP):** Antenna array with one or more antenna elements available to the network located at a specific geographical location for a specific area. + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in [2] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, as in [2]. + +| | | +|-------|------------------------------------------------------------------------------------| +| 7-2 | Fronthaul interface split option as defined by O-RAN WG4, also referred to as 7-2x | +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth-Generation Mobile Communications | +| 5GC | 5G Core | +| ACS | Adjacent Channel Selectivity | +| ADC | Analog to Digital Converter | +| ASIC | Application Specific Integrated Circuit | +| ATA | Advanced Technology Attachment | +| BBDEV | Baseband Device | +| BH | Backhaul | +| BMC | Baseband Management Controller | +| BPSK | Binary Phase Shift Keying | +| BS | Base Station | + +| | | | +|----|---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | CISPR | International Special Committee on Radio Interference | +| 2 | CFR | Crest Factor Reduction | +| 3 | CU | Centralized Unit as defined by 3GPP | +| 4 | COM | Cluster Communication | +| 5 | CPRI | Common Public Radio Interface | +| 6 | CPU | Central Processing Unit | +| 7 | CRC | Cyclic Redundancy Check | +| 8 | DAC | Digital to Analog Converter | +| 9 | DDC | Digital Down Conversion | +| 10 | DDR | Double Data Rate | +| 11 | DIMM | Dual-Inline-Memory-Modules | +| 12 | DL | Downlink | +| 13 | DPD | Digital Pre-Distortion | +| 14 | DPDK | Data Plane Development Kit | +| 15 | DSP | Digital Signal Processor | +| 16 | DU | Distributed Unit as defined by 3GPP | +| 17 | DUC | Digital Up Conversion | +| 18 | ECC | Error Correcting Code | +| 19 | eCPRI | evolved Common Public Radio Interface | +| 20 | EMC | Electro Magnetic Compatibility | +| 21 | EVM | Error Vector Magnitude | +| 22 | FCC | Federal Communications Commission | +| 23 | FEC | Forward Error Correction | +| 24 | FFT | Fast Fourier Transform | +| 25 | FH | Fronthaul | +| 26 | FHGW | Fronthaul Gateway | +| 27 | FHM <sub>x</sub> | Fronthaul Multiplexer with no FH protocol translation, supporting an O-DU <sub>x</sub> with split option x and an O-RU <sub>x</sub> with split option x, with currently available options 6→6, 7-2→7-2 and 8→8 | +| 28 | | | +| 29 | FHGW <sub>x→y</sub> | Fronthaul Gateway that can translate fronthaul protocol from an O-DU <sub>x</sub> with split option x to an O-RU <sub>y</sub> with split option y, with currently available option 7-2→8. | +| 30 | | | +| 31 | FHHL | Full Height Half Length | +| 32 | FPGA | Field Programmable Gate Array | +| 33 | GbE | Gigabit Ethernet | +| 34 | GNSS | Global Navigation Satellite System | +| 35 | GPP | General Purpose Processor | +| 36 | GPS | Global Positioning System | +| 37 | HARQ | Hybrid Automatic Repeat request | +| 38 | HHHL | Half Height Half Length | +| 39 | IEEE | Institute of Electrical and Electronics Engineers | +| 40 | IFFT | Inverse Fast Fourier Transform | +| 41 | IMD | Inter Modulation Distortion | + +| | | | +|----|-------------------|-----------------------------------------------------------------------------------------------------| +| 1 | I/O | Input/Output | +| 2 | JTAG | Joint Test Action Group | +| 3 | L1 | Layer 1 | +| 4 | LDPC | Low-Density Parity Codes | +| 5 | LRDIMM | Load-Reduced Dual In-line Memory Module | +| 6 | LTE | Long Term Evolution | +| 7 | LVDS | Low-Voltage Differential Signaling | +| 8 | MAC | Media Access Control | +| 9 | MCP | Multi-Chip Package | +| 10 | MH | Midhaul | +| 11 | MIG | Memory Interface Generator | +| 12 | MII | Media-Independent interface | +| 13 | MIMO | Multiple Input Multiple Output | +| 14 | MU-MIMO | Multiple User MIMO | +| 15 | NEBS | Network Equipment-Building System | +| 16 | NetConf | Network Configuration Protocol | +| 17 | NFV | Network Functions Virtualization | +| 18 | NIC | Network Interface Controller | +| 19 | NR | New Radio | +| 20 | O-CU | O-RAN Centralized Unit as defined by O-RAN | +| 21 | O-DU <sub>x</sub> | A specific O-RAN Distributed Unit having fronthaul split option x where x may be 6, 7-2 (as | +| 22 | | defined by WG4) or 8 | +| 23 | O-RU <sub>x</sub> | A specific O-RAN Radio Unit having fronthaul split option x, where x is 6, 7-2 (as defined by | +| 24 | | WG4) or 8, and which is used in a configuration where the fronthaul interface is the same at the O- | +| 25 | | DU <sub>x</sub> | +| 26 | OCXO | Oven Controlled Crystal Oscillator | +| 27 | PCIe | Peripheral Component Interface Express | +| 28 | PDCP | Packet Data Convergence Protocol | +| 29 | PHY | Physical Layer | +| 30 | PMBus | Power Management Bus | +| 31 | POE | Power over Ethernet | +| 32 | PPS | Pulse Per Second | +| 33 | PRACH | Physical Random Access Channel | +| 34 | QAM | Quadrature Amplitude Modulation | +| 35 | QPSK | Quadrature Phase Shift Keying | +| 36 | QSFP | Quad Small Form-factor Pluggable | +| 37 | RAN | Radio Access Network | +| 38 | RDIMM | Registered Dual In-line Memory Module | +| 39 | RF | Radio Frequency | +| 40 | RoE | Radio over Ethernet | +| 41 | RU | Radio Unit as defined by 3GPP | + +| | | | +|----|------|-------------------------------------------| +| 1 | RX | Receiver | +| 2 | SATA | Serial ATA | +| 3 | SDU | Service Data Unit | +| 4 | SFP | Small Form-factor Pluggable | +| 5 | SFP+ | Small Form-factor Pluggable plus | +| 6 | SOC | System On Chip | +| 7 | SPI | Serial Peripheral Interface | +| 8 | SSD | Solid State Drive | +| 9 | TCXO | Temperature Compensate Crystal Oscillator | +| 10 | TDP | Thermal Design Power | +| 11 | TR | Technical Report | +| 12 | TS | Technical Specification | +| 13 | TX | Transmitter | +| 14 | UL | Uplink | +| 15 | USB | Universal Serial Bus | +| 16 | WG | Working Group | + +# Chapter 2 Hardware Reference Design 1 + +This chapter describes a white box hardware reference design example for indoor Picocell deployment scenario. It includes O-CU, O-DU<sub>8</sub> O-RU<sub>8</sub>, and FHM<sub>8</sub> for IPC deployment scenario. + +## 2.1 O-CU Hardware Reference Design + +The O-CU white box hardware is the platform that perform the O-CU function of upper l2 and l3. The hardware systems specified in this document meet the computing, power and environmental requirements of use cases configurations and feature sets of RAN physical node. These requirements are described in the hardware architecture and requirement specification [6] as well as in the use cases document [1]. The O-CU hardware includes the chassis platform, mother board, peripheral devices and cooling devices. The mother board contains processing unit, memory, the internal I/O interfaces, and external connection ports. The midhaul (MH) and backhaul (BH) interface are used to carry the traffic between O-CU and O-DU<sub>8</sub> as well as O-CU and core network. The other hardware functional components include: the storage for software, hardware and system debugging interfaces, board management controller, just to name a few; the O-CU designer will make decision based on the specific needs of the implementation. + +The HW reference design of O-CU is the same as o-du<sub>8</sub> except for the need of HW accelerator, thus detail design will be described in o-du<sub>8</sub> section 2.2. + +## 2.2 O-DU<sub>8</sub> Hardware Reference Design + +The O-DU<sub>8</sub> white box hardware is the platform that performs the DU function of L1 and lower L2. The hardware systems specified in this document meet the computing, power and environmental requirements of use cases configurations and feature sets of RAN physical node. These requirements are described in the early hardware requirement specification as well as in the use cases document. The O-DU<sub>8</sub> hardware includes the chassis platform, mother board, peripheral devices and cooling devices. The mother board contains processing unit, memory, the internal I/O interfaces, and external connection ports. The fronthaul and backhaul interface are used to carry the traffic between O-RU<sub>8</sub>/FHM<sub>8</sub> and O-DU<sub>8</sub> as well as O-CU and O-DU<sub>8</sub>. The O-DU<sub>8</sub> design may also provide an interface for hardware accelerator if that option is preferred. The other hardware functional components include: the storage for software, hardware and system debugging interfaces, board management controller, just to name a few; the O-DU<sub>8</sub> designer will make decision based on the specific needs of the implementation. + +Note that the O-DU<sub>8</sub> HW reference design is also feasible for O-CU and integrated O-CU/ O-DU<sub>8</sub>. + +### 2.2.1 O-DU<sub>8</sub> High-Level Functional Block Diagram + +Figure 2-1 shows the major functional blocks of O-DU<sub>8</sub>. The digital processing unit handles the baseband processing workload. To make the processing more efficient, an accelerator can be used to assist with the baseband workload processing. The memory devices include the random-access memory (RAM) for temporary storage of data while flash memory is used for codes and logs. The storage device is for persistent storage. The external network cards can be used + +1 for fronthaul or backhaul connection. The baseboard management controller (BMC) is a microcontroller which + 2 monitors hardware operation on motherboard. The clock circuits provide digital processing unit with required clock + 3 signals. + +![Figure 2-1: O-DU8 Functional Block Diagram. A central 'Digital Processing Unit' block is connected to 'Accelerator', 'Baseboard Management Controller', and 'Clock' on the left, and 'DDR RAM', 'Flash Memory', 'Storage Drives', and 'Ethernet Card' on the right.](14bc0dad6c5c508f6277428770af3625_img.jpg) + +Figure 2-1: O-DU8 Functional Block Diagram. A central 'Digital Processing Unit' block is connected to 'Accelerator', 'Baseboard Management Controller', and 'Clock' on the left, and 'DDR RAM', 'Flash Memory', 'Storage Drives', and 'Ethernet Card' on the right. + +Figure 2-1: O-DU<sub>8</sub> Functional Block Diagram. + +### 2.2.2 O-DU<sub>8</sub> Hardware Design Description + +Figure 2-2 describes the components and connections inside the O-DU<sub>8</sub> white box. + +![Figure 2-2: Detailed hardware design of O-DU8. The diagram shows a central 'SoC CPU' (U1) connected to various components. On the left, there are DDR4 DIMMs (E1, D1, A1, B1), SATA3 ports (SATA3.0#3, #2, #1, #0), and LAN ports (JLAN1, JLAN4). On the right, there are PCIe ports (PCIe 3.0 x16, x1, x2, x4), USB ports (USB 3.0, USB 2.0), and M.2 connectors. At the bottom, there is a BMC (Baseboard Management Controller) connected to DDR4, FLASH, COM1/2, and a REAR IO section with various headers and connectors.](5d379ffcdf4ad708cb33813ed70a6bff_img.jpg) + +Figure 2-2: Detailed hardware design of O-DU8. The diagram shows a central 'SoC CPU' (U1) connected to various components. On the left, there are DDR4 DIMMs (E1, D1, A1, B1), SATA3 ports (SATA3.0#3, #2, #1, #0), and LAN ports (JLAN1, JLAN4). On the right, there are PCIe ports (PCIe 3.0 x16, x1, x2, x4), USB ports (USB 3.0, USB 2.0), and M.2 connectors. At the bottom, there is a BMC (Baseboard Management Controller) connected to DDR4, FLASH, COM1/2, and a REAR IO section with various headers and connectors. + +###### Figure 2-2: O-DU<sub>8</sub> Hardware Block Diagram + +As described in the previous section, the O-DU<sub>8</sub> hardware can be implemented with different design choices. Here, a system-on-a-chip (SoC) based design is presented as an example which processes most of the O-DU<sub>8</sub> workload. The accelerator can be used to perform some O-DU<sub>8</sub> workload functions based on the overall performance requirement. Several Ethernet controllers are used for front haul link, back haul link and remote console control connection. The other parts include: RAM, flash memory, and hard drive storage. The JTAG and USB ports are provided for hardware debug and local connection if needed. Figure 2-2 describes the components and connections of O-DU<sub>8</sub> hardware. Finally, BMC block is mainly responsible for monitoring the hardware status. + +### 2.2.3 O-DU<sub>8</sub> Hardware Components + +In this section, the details of the O-DU<sub>8</sub> hardware component's requirements, features and parameters are described. The components selection is based on the use case requirements which are listed in the hardware architecture and requirements document [6]. + +#### 2.2.3.1 Digital Processing Unit + +This example of the digital processing unit in O-DU<sub>8</sub> is based on the General Purpose Processor (GPP). + +##### a. Digital Processing Unit Requirement + +The GPP requirements are listed in the following table. + +**Table 2-1: The Processor Feature List** + +| Item Name | Description | +|--------------------------------------------|-------------| +| # of Cores | 16 | +| # of Threads | 32 | +| Base Frequency | 2.20 GHz | +| Max Turbo Frequency | 3.00 GHz | +| Cache | 22 MB | +| Thermal Design Power (TDP) | 100W | +| Max Memory Size (dependent on memory type) | 512 GB | +| Memory Types | DDR4 | +| Max # of Memory Channels | 4 | + +The interface specifications on the main board are as follows: + +**Memory Channel Interfaces:** The system memory capacity, type and related information are described in the following table. + +**Table 2-2: The Memory Channel Feature List** + +| Item Name | Description | +|----------------------|-------------------| +| Memory Types | DDR4 | +| # of Memory Channels | 4 | +| ECC LRDIMM | Up to 512GB | +| ECC RDIMM | Up to 256GB | +| Memory Speed | 2666/2400/2133MHz | + +| | | +|----------------|-------------------------| +| DIMM Sizes | 128GB, 64GB, 32GB, 16GB | +| Memory Voltage | 1.2 V | + +**PCIe:** PCIe Gen 3 should be supported by the processor. There are total of 32 PCIe lanes with 128 Gb/s bandwidth. The 32 PCIe lanes can be divided into two x16 slots by using a riser card. + +**Ethernet:** The system should be capable to offer aggregated 48 Gb/s Ethernet bandwidth. The breakout the ports are discussed in later section. When higher Ethernet bandwidth required, an Ethernet card can be installed in one of the PCIe slot. + +##### **b. Digital Processing Unit Design** + +The digital processing unit is a SoC device which is a 64-bit multi-core server class processor. This SoC includes an integrated Platform Controller Hub (PCH), integrated high-speed I/O, Integrated Memory Controllers (IMC), and four integrated 10 Gigabit Ethernet ports. + +The SOC supports 512-bit wide vector processing instruction set. It also supports hardware virtualization to enable dynamic provisioning of services as communication service providers extend network functions virtualization (NFV). Figure 2-2 shows the major functional blocks of the digital processing unit. + +#### 2.2.3.2 Hardware Accelerator + +Hardware accelerators can be used in O-DU<sub>8</sub> to offload computationally intensive functions and to optimize the performance under varying traffic and loading conditions. The acceleration functional requirements and implementation are system designer's choice; however, the O-DU<sub>8</sub> shall meet the minimum system performance requirements under various loading and deployment conditions. In most cases, a Field Programmable Gate Array (FPGA) or Application Specific Integrated Circuit (ASIC) based PCIe card can be used to optimize the system performance. The FPGA(s) are part of a Network Interface Controller (NIC) that further provides connectivity services. + +##### 2.2.3.2.1 Accelerator Design Solution 1 + +The O-DU<sub>8</sub> system is typically implemented using a multi-core processor and one or more hardware accelerators. Parts of O-DU<sub>8</sub> protocol stack can be implemented in software running on the multi-core processors, some of the computationally intensive L1 and L2 functions are offloaded to FPGA-based or similar hardware accelerators. This is a programmable hardware, which provides both flexibility and high computing capabilities. + +###### **a. Accelerator Requirements** + +The accelerator unit comprises one or more FPGAs (e.g., two FPGAs), sufficient amount of DDR4 memory, and synchronization circuitry where one of FPGAs is used for L1 functional offload and the other one is used to perform fronthaul connectivity functions/protocols. The FPGA for L1 offload uses dedicated cores for channel encoding/decoding as well as FPGA and processing resources for running L1 functions such as but not limited to rate matching and de-matching, interleaving and scrambling, demodulation and HARQ buffer management as well as OFDM modulation/demodulation and channel estimation. + +Key features of the FPGA-based accelerator include: + +- 2X10/25G CPRI or RoE fronthaul interface +- Built-in SyncE/IEEE1588v2 synchronization + external reference timing +- L1 offloading options + - LDPC encoding and decoding + - Polar encoding and decoding + +- HARQ management with on board DDR memory (including DDR controller and interfaces) +- Other L1 offloading candidates include PRACH detection, MIMO encoding and decoding, channel estimation +- Partial or full L1 functions can be offloaded. It is recommended to offload the user-plane channel coding chain and part of or the entire control-plane channel coding chain to the hardware accelerator. +- PCIe Gen3 x16, two Gen4 x8, or PCIe Gen3 x16 bifurcated to two Gen3 x8 +- GPP supported +- Standard PCIe FHHL card (It is assumed that the hardware accelerators further perform NIC functions). +- 8GB DDR4 memory for buffering +- Power consumption not to exceed 75W + +The accelerator requirements in hardware have been summarized in Table 2-3. + +**Table 2-3: Accelerator Hardware Component List** + +| Item Name | Description for FPGA 1 | Description for FPGA 2 | +|-----------------------------|------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------| +| SoC Resources | System Logic cells - 930K<br>CLB LUT - 425K<br>SDFEC -8<br>DSP Slices - 4,272<br>BRAM - 38.0Mb<br>URAM - 22.5Mb | System Logic cells - 1,143K<br>CLB LUT - 523K<br>CLB Flip-Flops -1,045K<br>DSP Slices - 1,968<br>BRAM - 34.6Mb<br>URAM - 36.0Mb | +| Form Factor | FHHL PCIe Form Factor | | +| PCIe Interface | x8 Gen1, Gen2, Gen3 interface to FPGA2 and<br>x8 Gen1, Gen2, Gen3 interface to FPGA1<br>have x16 to two x8 bifurcation | | +| On Board Memory | FPGA1 | FPGA2 | +| | Total Capacity 4 GB in PL, upgradeable to 8GB<br>Total Capacity 2 GB in PS, upgradeable to 4GB | Total Capacity 4 GB in PL, upgradeable to 8GB<br>Total Capacity 2 GB in PS, upgradeable to 4GB | +| Network Interface(s) | N/A | 2xSFP28 optical interfaces to FPGA2<br>(User Configurable, includes 10/25 Ethernet) | +| Other External Interface(s) | Micro USB for JTAG support (FPGA programming and debug) and access to BMC | | +| Graphical User interface | GUI for monitoring the basic board parameters, monitoring temperature alerts, firmware upgrades for BMC | | + +| | | +|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Board Management Controller | <ul style="list-style-type: none"> <li>• Power sequencing and reset</li> <li>• Field upgrades</li> <li>• FPGA configuration and control</li> <li>• Clock configuration</li> <li>• I2C bus access</li> <li>• USB 2.0</li> </ul> | +| Operating Temperature | -5°C - 55°C | +| Power | < 75 W | +| Clocking Options | Low-Jitter, configurable clock ranging from 10MHz to 750MHz<br>1 PPS input and output with assembly option for OCXO and TCXO | + +The following are the accelerator requirements in function and interface. + +###### **Functional offload requirements** + +One of the candidate functions for offloading is the LDPC encoder and decoder, which typically consists of computationally intensive and relatively highly power-consuming functions. It must be noted that neither software implementation in CPU nor soft FPGA logic implementation would provide a highly power-efficient solution while meeting/exceeding 3GPP NR user-plane encoder/decoder throughput and latency requirements, rather a hardened implementation of the FEC functions would be very power efficient. Downlink and uplink throughputs of up to 40Gbps and 18Gbps, respectively, are shown feasible with this architecture. Other candidate L1 functions for acceleration include CRC generation, segmentation, bit-level/sub-block interleaving and scrambling as well as FFT/IFFT processing, for which an FPGA can be used. + +For other symbol processing L1 functions, which require heavy multiply and accumulation operations, FPGAs 1 and 2 have DSP blocks that can efficiently perform these operations. Polar encoding and/or decoding on the control-plane can also be offloaded to FPGA1 resulting in high throughputs and low latencies. + +###### **Interface requirements** + +- **PCIe:** PCIe interface is widely used to provide interface between the GPP and hardware accelerators. FPGA devices have dedicated PCIe hard IP which facilitate implementation and quick setup of PCIe interface. They support both PCIe Gen3 x16 or PCIe Gen4 x8, which allow the FPGA device to interface with any GPP supporting either PCIe Gen3 x16 or PCIe Gen4 x8 interface. + +- **Fronthaul:** FPGA devices can support various speed grades and any fronthaul protocols, customers can use off-the-shelf CPRI or RoE IPs to quickly implement and configure any fronthaul interface protocol. + +- **Serial transceivers:** FPGA devices have SerDes resources to implement various connectivity speeds (e.g., 33 Gb/s) per SerDes, 10G/25G CPRI, 10G/25G/50G/100G Ethernet connections can use these SerDes resources. + +- **Ethernet MAC speed:** FPGA devices have hardened implementations of Ethernet MAC that support speeds of 100 Gb/s and above. The Ethernet MAC IP allows power-efficient implementation of high speed Ethernet connectivity. In the example shown in Figure 2-3, FPGA 1 and FPGA 2 can use the hard 100Gbps MAC IPs to connect each other, allowing the L1 and fronthaul functions to be distributed across these two FPGAs with less + +connectivity overhead. For other Ethernet MACs such as 10G/25G Ethernet, they provide soft Ethernet MAC IPs, so when implementing CPRI or RoE fronthaul functions, 10G/25G Ethernet MAC can be used. + +###### b. Accelerator Design + +The hardware accelerator supports GPP. Figure 2-3 illustrates a two-chip acceleration architecture comprising two FPGAs with multi-lane PCIe interfaces toward the CPU and external connectivity toward O-RU<sub>s</sub>(s) via CPRI/RoE and O-CU(s) through GbE connectivity. The example architecture further depicts multi-lane Gen3 or Gen4 PCIe interfaces between each FPGA and the CPU. The FPGAs communicate through high-bandwidth Ethernet (GbE) transport. + +![Figure 2-3: Example 2-chip FPGA-based Hardware Acceleration in O-DU8. The diagram shows a CPU (L2 and L1) connected to two FPGAs, FPGA1 (L1 Offload) and FPGA2 (Connectivity). The CPU has an F1 Interface GbE (10/25G) on the left. FPGA1 and FPGA2 are connected via a PCIe Interface PCIe Gen3x16 (Gen4x8) 100G. FPGA1 and FPGA2 are also connected via an Inter-Chip Interface 100G Ethernet. FPGA2 has a Fronthaul Interface 10/25G CPRI/RoE on the right.](d30b46386c6c863124083769c56c40de_img.jpg) + +``` + +graph LR + CPU[CPU +(L2 and L1)] + subgraph FPGAs + FPGA1[FPGA1 +(L1 Offload)] + FPGA2[FPGA2 +(Connectivity)] + FPGA1 ---|Inter-Chip Interface +100G Ethernet| FPGA2 + end + CPU <-->|PCIe Interface +PCIe Gen3x16 (Gen4x8) +100G| FPGA1 + CPU <-->|PCIe Interface +PCIe Gen3x16 (Gen4x8) +100G| FPGA2 + CPU <-->|F1 Interface +GbE (10/25G)| + FPGA2 <-->|Fronthaul Interface +10/25G +CPRI/RoE| + +``` + +Figure 2-3: Example 2-chip FPGA-based Hardware Acceleration in O-DU8. The diagram shows a CPU (L2 and L1) connected to two FPGAs, FPGA1 (L1 Offload) and FPGA2 (Connectivity). The CPU has an F1 Interface GbE (10/25G) on the left. FPGA1 and FPGA2 are connected via a PCIe Interface PCIe Gen3x16 (Gen4x8) 100G. FPGA1 and FPGA2 are also connected via an Inter-Chip Interface 100G Ethernet. FPGA2 has a Fronthaul Interface 10/25G CPRI/RoE on the right. + +Figure 2-3: Example 2-chip FPGA-based Hardware Acceleration in O-DU<sub>8</sub> + +##### 2.2.3.2.2 Accelerator Design Solution 2 + +This section illustrates a one-chip acceleration architecture comprising one FPGA with PCIe interfaces toward the CPU and external connectivity toward O-RU<sub>s</sub>(s). The example architecture further depicts Gen3 PCIe interfaces (for example, or Gen4) between FPGA and the CPU. + +An example one-chip FPGA-based hardware acceleration architecture is shown in Figure 2-4. + +![Figure 2-4: Example of 1-chip FPGA-based Hardware Acceleration in O-DU8. The diagram shows an O-DU block containing a CPU and a POWER UNIT. The CPU is connected to an FPGA via a PCIe Interface Gen3x16. The FPGA is connected to an Accelerator block via a Fronthaul Interface CPRI(25G/10G) and a Backhaul Interface 10G. The Accelerator block is connected to the POWER UNIT via an extra power supply 12V (possible). The Accelerator block also has connections for GNSS and 1588+syncE.](a19d88441b0034abc63769b4b18a48c4_img.jpg) + +Figure 2-4: Example of 1-chip FPGA-based Hardware Acceleration in O-DU8. The diagram shows an O-DU block containing a CPU and a POWER UNIT. The CPU is connected to an FPGA via a PCIe Interface Gen3x16. The FPGA is connected to an Accelerator block via a Fronthaul Interface CPRI(25G/10G) and a Backhaul Interface 10G. The Accelerator block is connected to the POWER UNIT via an extra power supply 12V (possible). The Accelerator block also has connections for GNSS and 1588+syncE. + +**Figure 2-4: Example of 1-chip FPGA-based Hardware Acceleration in O-DU<sub>8</sub>** + +###### *a. Accelerator Requirement* + +The accelerator unit comprises one or more FPGAs (e.g., two FPGAs), sufficient amount of DDR4 memory, and synchronization circuitry where one of FPGAs is used for L1 functional offload and the other one is used to perform fronthaul connectivity functions/protocols. The FPGA for L1 offload uses dedicated cores for channel encoding/decoding as well as FPGA and processing resources for running L1 functions such as but not limited to rate matching and de-matching, interleaving and scrambling, demodulation and HARQ buffer management as well as OFDM modulation/demodulation and channel estimation. + +Key features of the FPGA-based accelerator include: + +- 4X25G/10G CPRI optical interface +- 1x10G Ethernet optical interface +- Support GNSS/IEEE1588v2+syncE reference timing +- L1 offloading options + - LDPC encoding and decoding + - HARQ management + +- Other optional L1 offloading such as FFT/IFFT, CP, CRC, rate matching, PRACH detection. +- PCIe Gen3X16, 4 hard IP blocks +- FHHL form factor and operation temperature from -5°C to +55°C +- 2GB DDR4 memory for Buffering +- Specific power supply design is required with 1-chip FPGA, since the maximum power consumption of PCIe specification (75w) could be exceeded, additional external auxiliary power may be required. + +###### **Functional offload requirements** + +- **L1 offloading:** One of the functions for L1 offloading is the LDPC encoder and decoder, which typically consists of computationally-intensive and relatively highly power-consuming functions. Other L1 functions for acceleration include CRC generation, CP, PRACH detection and rate matching as well as FFT/IFFT processing. +- **Fronthaul:** The data transmission and protocol processing of fronthaul interface is completed on the FPGA device. + +###### **Interface requirements** + +- **PCIe:** PCIe interface is widely used to provide interface between the CPU and hardware accelerators. FPGA device has dedicated PCIe hard IP which facilitate implementation and quick setup of PCIe interface. FPGA support PCIe Gen3 x16, which allow the FPGA device to interface with any CPU supporting either PCIe Gen3 x16 interface. +- **Fronthaul:** FPGA device can support various speed grades and CPRI protocol for fronthaul interface between O-DU<sub>8</sub> and O-RU<sub>8</sub>. +- **Backhaul:** FPGA device can support backhaul interface between O-DU<sub>8</sub> and core network function with an 10G optical interface. +- **Synchronization:** Accelerator has external interfaces to support synchronization, including GNSS, IEEE1588v2 and SyncE reference timing. + +###### *b. Accelerator Design* + +![Block diagram of an Accelerator Design showing internal components and external connections.](ecbbe55f6b2adfb57320031f86d04c05_img.jpg) + +The diagram illustrates the internal architecture of an accelerator design. A central **FPGA** is connected to various components: + +- Power and Control:** A **Power Supply Sequencer and Monitor** provides power to an **MCU** and a **DC/DC** converter. The **DC/DC** converter is controlled by an **EN** signal and provides **12V** power to a **Positive hot swap controller**, which in turn provides **AUX\_POWER** to the **FPGA**. +- Timing and Clocking:** A **Clock Chip** provides a **1PPS** signal to the **FPGA** and a **1588/GPS 1PPS** signal to a **Mixer**. The **Mixer** is connected to an **SMA** port, which is linked to a **GNSS ANT**. +- Data and I/O:** The **FPGA** is connected to **10G Backhaul** and **4\*25G Fronthaul** ports. It also has connections to **LED**, **RJ45**, **DDR4**, **QSPI\_Flash**, **JTAG**, and **OSC**. +- External Interface:** The **FPGA** is connected to an **O-DU server** via a **PCIe** interface, which is highlighted with a green bar. + +Block diagram of an Accelerator Design showing internal components and external connections. + +**Figure 2-5: Example of Accelerator Design** + +Figure 2-5 shows the accelerator design, description of block diagram of board card: + +**12V power:** The maximum power consumption of the whole card is estimated to exceed 75W. The PCIe cannot meet the power consumption demand, so it needs an external 12V auxiliary power supply. The extra power consumption can be included by the power unit of O-DU<sub>8</sub>. Only power cord is needed, and it has no effect on the whole machine design. This part is not necessary if there are future optimizations. + +**DC/DC:** The module contains all the power sources used in the system. + +**Power Supply Sequencer and Monitor:** Since the system has the power on timing requirement, this module controls the output of each DC/DC to realize the normal power on/off of the system. + +**Mixer and GNSS antenna:** The system uses an external antenna, which can be placed outdoors to improve the receiving sensitivity of synchronizing signal. After mixer's processing of the received signal, the signal source of 1pps is output to clock chip for system input synchronous clock signal. + +**MCU (micro control unit):** As the auxiliary processor of the board card, MCU realizes the temperature detection of the board card, the operation state indication and the configuration of power monitor and clock chip in the initialization process, and real-time monitoring of the working state of each module, exception handling and other functions. + +**Clock chip:** The chip realizes system-level clock input, which can synchronously output all kinds of clocks for clock synchronization of subordinate modules. + +**FPGA:** As the core chip of the board card, FPGA forwards the data of the downlink of the core network and the uplink data gathered at the O-RU<sub>8</sub>(s), and interacts with the O-DU<sub>8</sub> server through PCIe x16 to complete the calculation of 5G NR data. + +##### 2.2.3.2.3 Accelerator Design Solution 3 + +Channel coding for LDPC and fronthaul compression requires a significant amount of bit level processing and is well suited to a fine-grained FPGA architecture and/or low cost/power structured ASIC. Options include: + +- Look-aside FEC: LDPC (de)coding, Polar (de)coding, Rate (De)Matcher, (De) Interleaver, CRC, HARQ +- L1 Processing: (i)FFT & CP+/-, PRACH, channel estimation & beamforming +- Bump-in-wire Fronthaul: compression / decompression for latency and bandwidth reduction + +###### a. Accelerator Requirement + +Hardware requirements are listed in Table 2-4. + +**Table 2-4: Accelerator Hardware Feature List** + +| Item Name | Description | +|-----------------------------------------------|---------------------------------------------| +| PCIe (Interface with digital processing unit) | Gen4 x16 (and lower) | +| Form factor | FHHL | +| Connectivity | 2x QSFP28/56 | +| FPGA | Logic Elements: 1437K<br>M20K Memory: 139Mb | + +| | | +|---------------------------------|-------------------------------------------------------------------------------------------------| +| | Quad-core GPP Hard Processor Sub-system | +| NIC Device | 100Gb xHAUL for FH, BH & MH traffic shaping. Optional FPGA co-processing. | +| DDR Main | 8+8+1GB DDR4 | +| Flash (FPGA images) | >=1 Gbit | +| BMC | Telemetry, Security, remote upgrade | +| Clocking | For O-RAN C1, C2, C3 & C4 | +| Fronthaul | CPRI | +| GPS | SMA for 1PPS & 10MHz (in/out) | +| Operating Temperature (ambient) | NEBS Compliant | +| Power | <75W (without optional NIC device) | +| Clock Accuracy | Low-Jitter, configurable clock ranging from 10MHz to 750MHz. Option for OCXO (TCXO as standard) | + +Firmware Requirements are listed in Table 2-5. + +**Table 2-5: Accelerator Firmware Feature List** + +| Item Name | Description | +|------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Remote system upgrade | Securely upgradable FPGA flash image | +| Queuing | 64 Queues supported equally split between UL & DL. | +| LDPC Acceleration | NR LDPC Encoding with, interleaving and rate-matching.<br>NR LDPC Decoding with sub-block de-interleaving function of reverse rate matching.<br>Early Termination, CRC attachment and HARQ buffering.<br>5G Throughput: DL 14.8Gbps, UL 3.2Gbps | +| Load Balancing (channel coding) | Load balancer distributes the pending encoder/decoder requests to encoder/decoders | +| Descriptor Format (channel coding) | Code block based interface.<br>Software enablement by BBDEV API (DPDK)<br><a href="https://www.dpdk.org/">https://www.dpdk.org/</a><br><a href="https://doc.dpdk.org/guides/prog_guide/bbdev.html">https://doc.dpdk.org/guides/prog_guide/bbdev.html</a> | +| Fronthaul Compression | In-line compression/decompression for Mu-Law, block-floating point and quantization according to the O-RAN WG4 specification. | +| Open programmable acceleration | Support for: | + +| | | +|-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| environment | <ul style="list-style-type: none"> <li>• FPGA Flashing upgrade</li> <li>• Firmware version reporting</li> <li>• PCIe diagnostics</li> <li>• Ethernet diagnostics</li> <li>• Temperature and voltage telemetry information</li> </ul> | +|-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +###### b. Accelerator Design + +Accelerator design solution 3 has 2 options as shown in the figures below. + +![Figure 2-6: Accelerator Design 1 without optional NIC Device. This block diagram shows a 'Digital Processing Unit' (L3, L2, L1(part)) connected to an 'FPGA' block. The FPGA contains 'Connectivity & L1 Processing. C1,2,3,4 Sync'. The connection between the Digital Processing Unit and the FPGA is labeled 'PCIe Gen 4x16 Or lower (200G)'. The FPGA is connected to an external output labeled 'FH 2x2x56Gbps Or lower'. Below the FPGA, a '1PPS & 10MHz SMA' signal is shown.](5096848b75864ddba01ac0905c5d56cb_img.jpg) + +Figure 2-6: Accelerator Design 1 without optional NIC Device. This block diagram shows a 'Digital Processing Unit' (L3, L2, L1(part)) connected to an 'FPGA' block. The FPGA contains 'Connectivity & L1 Processing. C1,2,3,4 Sync'. The connection between the Digital Processing Unit and the FPGA is labeled 'PCIe Gen 4x16 Or lower (200G)'. The FPGA is connected to an external output labeled 'FH 2x2x56Gbps Or lower'. Below the FPGA, a '1PPS & 10MHz SMA' signal is shown. + +Figure 2-6: Accelerator Design 1 without optional NIC Device + +The accelerator with optional NIC device. + +![Figure 2-7: Accelerator Design 1 with optional NIC Device. This block diagram shows the same components as Figure 2-6, but with an additional 'NIC' (Network Interface Card) block. The 'Digital Processing Unit' (L3, L2, L1(part)) is connected to the 'FPGA' block via 'PCIe Gen4x16'. Inside the FPGA, the 'Connectivity & L1 Processing. C1,2,3,4 Sync' block is connected to the 'NIC' block via 'PCIe Gen 4x8 Or lower (100G)'. The 'FPGA' block is also connected to an external output labeled 'FH 2x2x56Gbps Or lower'. A '100Gb' connection is shown between the 'Connectivity & L1 Processing' block and the 'NIC' block. A '1PPS & 10MHz SMA' signal is also shown.](1cbed3f91ba956e852eaabb5376daf87_img.jpg) + +Figure 2-7: Accelerator Design 1 with optional NIC Device. This block diagram shows the same components as Figure 2-6, but with an additional 'NIC' (Network Interface Card) block. The 'Digital Processing Unit' (L3, L2, L1(part)) is connected to the 'FPGA' block via 'PCIe Gen4x16'. Inside the FPGA, the 'Connectivity & L1 Processing. C1,2,3,4 Sync' block is connected to the 'NIC' block via 'PCIe Gen 4x8 Or lower (100G)'. The 'FPGA' block is also connected to an external output labeled 'FH 2x2x56Gbps Or lower'. A '100Gb' connection is shown between the 'Connectivity & L1 Processing' block and the 'NIC' block. A '1PPS & 10MHz SMA' signal is also shown. + +Figure 2-7: Accelerator Design 1 with optional NIC Device + +![Figure 2-8: Structured ASIC Accelerator Design. A block diagram showing a 'Digital Processing Unit' (containing L3, L2, L1(part)) connected via a bidirectional arrow labeled 'PCIe Gen 3x16 Or lower (100G)' to a 'Structured ASIC' block. The 'Structured ASIC' block contains an 'LDPC Code/Transport Block'.](d50485084e8aa5ee57b0a9bf47f07cfc_img.jpg) + +``` + +graph LR + DPU[Digital Processing Unit +L3,L2,L1(part)] <-->|PCIe Gen 3x16 +Or lower (100G)| SA[Structured ASIC] + subgraph SA [Structured ASIC] + LDPC[LDPC Code/Transport Block] + end + +``` + +Figure 2-8: Structured ASIC Accelerator Design. A block diagram showing a 'Digital Processing Unit' (containing L3, L2, L1(part)) connected via a bidirectional arrow labeled 'PCIe Gen 3x16 Or lower (100G)' to a 'Structured ASIC' block. The 'Structured ASIC' block contains an 'LDPC Code/Transport Block'. + +**Figure 2-8: Structured ASIC Accelerator Design** + +##### 2.2.3.2.4 Accelerator Design Solution 4 + +Channel coding for LDPC and fronthaul compression requires a significant amount of bit level processing and is well suited to a fine-grained structured ASIC. Features include: + +- Look-aside FEC: Turbo (de)coding, LDPC (de)coding, Rate (De)Matcher, (De) Interleaver, CRC, HARQ retransmission & (de)interleaver. + +###### *a. Accelerator Requirement* + +Hardware features are listed in Table 2-6. + +**Table 2-6: Accelerator Hardware Feature List** + +| Item Name | Description | +|-----------------------------|-----------------------------------------------------------| +| PCIe | Gen3 x16 | +| Form factor | HHHL | +| DDR | DDR4 (64-bit +ECC), 2667Mbps Interface for HARQ buffering | +| Board Management Controller | Telemetry, Security. | +| Power | <35W | + +Firmware Requirements are listed in Table 2-7. + +**Table 2-7: Accelerator Firmware Feature List** + +| Item Name | Description | +|-------------------|----------------------------------------------------------------------------------------------------------------------------------------------| +| Queuing | 64 Queues supported equally split between UL & DL. | +| LDPC Acceleration | NR LDPC Encoding with, interleaving and rate-matching.<br>NR LDPC Decoding with sub-block de-interleaving function of reverse rate matching. | + +| | | +|------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Early Termination, CRC attachment and HARQ buffering.<br>5G Throughput: DL 23Gbps, UL 8Gbps | +| Load Balancing (channel coding) | Load balancer distributes the pending encoder/decoder requests to encoder/decoders | +| Descriptor Format (channel coding) | Code block and transport block based interface.<br>Software enablement by BBDEV API (DPDK)<br><a href="https://www.dpdk.org/">https://www.dpdk.org/</a><br><a href="https://doc.dpdk.org/guides/prog_guide/bbdev.html">https://doc.dpdk.org/guides/prog_guide/bbdev.html</a> | + +###### b. Accelerator Design + +The following diagram shows the structured ASIC based accelerator design. + +![Figure 2-9: Structured ASIC Accelerator Design. The diagram shows a 'Digital Processing Unit' (L3, L2, L1(part)) connected to a 'Structured ASIC' (LDPC Code/Transport Block) via a 'PCIe Gen 3x16 Or lower (100G)' interface.](38840e43170a542e6bc3a28cbb086a42_img.jpg) + +``` + +graph LR + DPU[Digital Processing Unit +L3,L2,L1(part)] <-->|PCIe Gen 3x16 +Or lower (100G)| ASIC[Structured ASIC +LDPC Code/Transport Block] + style ASIC fill:#d4edda + +``` + +Figure 2-9: Structured ASIC Accelerator Design. The diagram shows a 'Digital Processing Unit' (L3, L2, L1(part)) connected to a 'Structured ASIC' (LDPC Code/Transport Block) via a 'PCIe Gen 3x16 Or lower (100G)' interface. + +**Figure 2-9: Structured ASIC Accelerator Design** + +#### 2.2.3.3 Baseboard Management Controller + +BMC is used to perform hardware power control (power on, power off and power cycle), monitor hardware status (temperatures, voltages, etc.), monitor Basic I/O System (BIOS)/ Unified Extensible Firmware Interface (UEFI) firmware status, and log system events. It provides remote access via shared or dedicated NIC. System user can do console access via serial or physical/Kernel-based Virtual Machine (KVM). The BMC has dedicated RAM and flash memory. It provides access via serial port or Ethernet port. Figure 2-2 describes the BMC connections with related components. + +### 2.2.4 Synchronization and Timing + +#### 2.2.4.1 Synchronization and Timing Design 1 + +This section describes the synchronization and timing mechanism that is used in the O-DU<sub>8</sub>. + +###### 1 a. Hardware Requirements + +2 The O-DU<sub>8</sub> shall support following timing synchronization methods: + +- 3 1. GPS Synchronization +- 4 2. Ethernet based IEEE1588v2 Synchronization +- 5 3. BeiDou Synchronization +- 6 4. BeiDou and GPS switching + +###### 7 b. Hardware Design + +8 Depending on the timing distribution topologies used, the O-DU<sub>8</sub> system clock is able to synchronize with the +9 Grand Master Clock (GMC) using IEEE1588 via either the front haul NIC or backhaul NIC. O-DU<sub>8</sub> can also +10 synchronize timing using Global Navigation Satellite System (GNSS). In the case of IEEE1588, the Physical +11 Hardware Clock (PHC) within the NIC is synchronized with the GMC first, then the O-DU<sub>8</sub> system clock is +12 synchronized with the PHC. The O-DU<sub>8</sub> is also capable to provide clock to the O-RU<sub>8</sub> via front haul if needed. +13 When GNSS becomes available to O-DU<sub>8</sub>, it will be able to synchronize the system clock to Coordinated +14 Universal Time (UTC). Figure 2-10 outlines the O-DU<sub>8</sub> timing synchronization mechanisms. + +![Figure 2-10: O-DU8 Timing Synchronization diagram. The diagram shows a central 'System Clock' block. To its left is a 'NIC' block containing a 'PHC' (Physical Hardware Clock). A double-headed arrow connects the 'System Clock' to the 'PHC' in the left 'NIC'. Below the left 'NIC' is a 'Backhaul' connection. To the right of the 'System Clock' is another 'NIC' block containing a 'PHC'. A double-headed arrow connects the 'System Clock' to the 'PHC' in the right 'NIC'. Above the right 'NIC' is a 'GNSS' block with a '1pps' signal line pointing down to the 'PHC'. Below the right 'NIC' is a 'Fronthaul' connection.](81dbfc8e237f251d95e60deef762f38d_img.jpg) + +Figure 2-10: O-DU8 Timing Synchronization diagram. The diagram shows a central 'System Clock' block. To its left is a 'NIC' block containing a 'PHC' (Physical Hardware Clock). A double-headed arrow connects the 'System Clock' to the 'PHC' in the left 'NIC'. Below the left 'NIC' is a 'Backhaul' connection. To the right of the 'System Clock' is another 'NIC' block containing a 'PHC'. A double-headed arrow connects the 'System Clock' to the 'PHC' in the right 'NIC'. Above the right 'NIC' is a 'GNSS' block with a '1pps' signal line pointing down to the 'PHC'. Below the right 'NIC' is a 'Fronthaul' connection. + +15 +16 **Figure 2-10: O-DU<sub>8</sub> Timing Synchronization** + +###### 18 2.2.4.2 Synchronization and Timing Design 2 + +19 This section describes the synchronization and timing mechanism that is used in the hardware accelerator board. + +###### 20 a. Hardware Requirements + +21 Each hardware accelerator board that supports connectivity functions in O-DU<sub>8</sub> must be able to support +22 external synchronization I/O and to receive or transmit 1 PPS reference clock source in order to ensure +23 synchronization across network. + +###### 24 b. Hardware Design + +25 The accelerator board can operate in the master or slave mode when supporting IEEE 1588v2 +26 timing/synchronization. It can generate 1 PPS reference clock for synchronization in the master mode and can +27 receive the 1 PPS reference clock in the slave mode for internal synchronization. The timing circuitry of the +28 accelerator board is shown in Figure 2-11. Two FPGA SerDes transceivers are used to receive and transmit +29 SyncE TX and RX clocks. +30 + +![Figure 2-11: HW Acceleration Board Timing and Synchronization diagram. The diagram shows a PLL block receiving three inputs: SyncE RX Clock, TCXO/OCXO Reference, and GPS (1 PPS). The PLL outputs three signals to a SerDes FPGA (IEEE 1588v2 Stack) block: SyncETX Clock, 1 PPS, and Other Clocks. A feedback loop connects the SerDes FPGA back to the PLL via the SyncE RX Clock line.](157004908c0c5923ae522e816182b74f_img.jpg) + +``` + +graph LR + SyncERX[SyncE RX Clock] --> PLL[PLL] + TCXO[TCXO/OCXO Reference] --> PLL + GPS[GPS 1 PPS] --> PLL + PLL -- SyncETX Clock --> SerDesFPGA[SerDes FPGA IEEE 1588v2 Stack] + PLL -- 1 PPS --> SerDesFPGA + PLL -- Other Clocks --> SerDesFPGA + SerDesFPGA -- SyncE RX Clock --> PLL + +``` + +Figure 2-11: HW Acceleration Board Timing and Synchronization diagram. The diagram shows a PLL block receiving three inputs: SyncE RX Clock, TCXO/OCXO Reference, and GPS (1 PPS). The PLL outputs three signals to a SerDes FPGA (IEEE 1588v2 Stack) block: SyncETX Clock, 1 PPS, and Other Clocks. A feedback loop connects the SerDes FPGA back to the PLL via the SyncE RX Clock line. + +**Figure 2-11: HW Acceleration Board Timing and Synchronization** + +### 2.2.5 External Interface Ports + +The external interfaces of O-DU<sub>8</sub> are described below. + +#### *a. Hardware Requirements* + +The following table shows the external ports or slots that the system provided. + +**Table 2-8: External Port List** + +| Item Name | Description | +|--------------|-------------------------------------------| +| Ethernet | Octave Gigabit Ethernet LAN connectors | +| | Dual 10GbE Base-T Ethernet connectors | +| | Dual 10GbE SFP+ Faber Ethernet connectors | +| | 2x100G QSFP28 or 2x25G SFP28 | +| USB | 2 USB 3.0 ports | +| Serial Port | 1 COM port via RJ45 | +| Antenna port | 1 SMA connector for GNSS | + +#### *b. Hardware Design* + +The digital processing unit is a SoC device which provides the external ports described in the hardware requirement section. The system includes 2 USB 3.0 ports, and the serial RS232 port that can be used for Console Redirection, e.g. Out-of-Band Management. The system provides eight 1Gbps and four 10Gbps Ethernet ports. There are two or four 25G CPRI ports in system depends on the accelerator card used. The system also provides a RF interface to connect GNSS antenna. The following diagram outlines the external interfaces that supported. + +![Figure 2-12: External interfaces reference design. A central box labeled 'O-DU8' is connected to five external interface boxes: '2 USB 3.0 Ports', 'Serial Port', 'GNSS Antenna Port', '2 or 4 25G CRPI Ports', and 'Ethernet Ports'. Each connection is represented by a double-headed arrow.](17c52ff5b82f716452bde91f2df04c38_img.jpg) + +``` + +graph LR + ODU8[O-DU8] <--> USB[2 USB 3.0 Ports] + ODU8 <--> Serial[Serial Port] + ODU8 <--> GNSS[GNSS Antenna Port] + ODU8 <--> CRPI[2 or 4 25G CRPI Ports] + ODU8 <--> Ethernet[Ethernet Ports] + +``` + +Figure 2-12: External interfaces reference design. A central box labeled 'O-DU8' is connected to five external interface boxes: '2 USB 3.0 Ports', 'Serial Port', 'GNSS Antenna Port', '2 or 4 25G CRPI Ports', and 'Ethernet Ports'. Each connection is represented by a double-headed arrow. + +**Figure 2-12: External interfaces reference design** + +### 2.2.6 O-DU<sub>8</sub> Firmware + +BIOS and BMC firmware are needed in the system and shall be installed. + +### 2.2.7 Mechanical + +The mechanical design for mother board, chassis, and cooling are listed in this section. + +#### - Mother Board** + +The mechanical layout of the mother board shows the location of major components and interface ports. The following diagram also provides the dimension of the board. + +![Mother Board Layout Diagram showing components, dimensions, and a central SoC.](c8ba1e5d78b448267736ac4960ad57bd_img.jpg) + +The diagram illustrates the mechanical layout of a mother board. The board is rectangular with a width of 8 inches and a height of 10 inches. A central red square represents the SoC, measuring 45x52.5mm. The layout includes various components and ports: + +- Top Edge:** LAN7, LAN8, LAN5, LAN6, LAN3, LAN4, LAN1, LAN2 (all RJ45). USB3.0 x2, IPMI. +- Right Edge:** SATA, SATA, SoC SMBus, PWRI2Q, USB 2.0, DOF4 2667MHz, TPM Header, I2C B-key, I2C M-key, ATX 24 pin. +- Bottom Edge:** SATA, SATA, Fan1, Fan2, Fan3, Fan4, Fan5, Front Panel. +- Left Edge:** VGA, COM, VGA, COM, Phy 10GbE S422T, LAN LEDs/GPIO, USB TypeA. +- Internal Components:** 10GbE BaseT x2, 10GbE x2 SFP+, NIC, BMC, 12 B-key, LAN LEDs/GPIO, USB TypeA, Front Panel. + +Mother Board Layout Diagram showing components, dimensions, and a central SoC. + +Figure 2-13: Mother Board Layout Diagram + +#### Chassis + +The 1U rack mount chassis contains the layout of the power supply, Solid State Drive (SSD) and fans. The chassis dimension is showed in following figure. + +![Figure 2-14: Chassis Mechanical Diagram. A 3D perspective view of a 1U rack mount chassis. The diagram shows the internal layout with a 'Power Supply' unit at the top, an 'SSD' unit below it, and a fan array on the right side. Two fan configurations are shown: 'Installed Fans' (4 fans) and 'Optional Fans' (6 fans). Dimensions are indicated: the total width is 437 mm, the depth is 381 mm, and the height is 43 mm.](b883effb042684251cbba5d4e661b3a5_img.jpg) + +Figure 2-14: Chassis Mechanical Diagram. A 3D perspective view of a 1U rack mount chassis. The diagram shows the internal layout with a 'Power Supply' unit at the top, an 'SSD' unit below it, and a fan array on the right side. Two fan configurations are shown: 'Installed Fans' (4 fans) and 'Optional Fans' (6 fans). Dimensions are indicated: the total width is 437 mm, the depth is 381 mm, and the height is 43 mm. + +Figure 2-14: Chassis Mechanical Diagram + +#### Cooling + +The system installs 4x 40x28mm PWM fans for the cooling. Up to 6 fans can be installed if needed. + +### 2.2.8 Power Unit + +In a fully loaded system with two PCIe slots populated with 75W each, the system power consumption should be less than 400W. The total system power requirement shall be kept less than 80% of the power supply capacity. + +#### a. Hardware Requirements + +The power is provided by 500W High-Efficiency power supply with Power Management Bus (PMBus) 1.2. + +The power support input and output power rails are listed below. + +AC Input: 100-240V, 50-60Hz, 6.6A max + +DC Output: +3.3V: 12A + ++5V: 15A + ++5V standby: 3A + ++12V: 41A + +-12V: 0.2A + + + +#### b. Hardware Requirements + +The O-DU<sub>8</sub> chassis includes one 500W power supply unit. The power supply unit is auto-switching capable, which enables it to automatically sense and operate at a 100v to 240v input voltage. The power supply unit features are listed in the following table. + +**Table 2-9: Power supply unit feature list** + +| Item Name | Description | +|-----------------------------|----------------------------------------------------------------| +| Output connectors | 24pin/8pin/4+4pin/HDD/I2C | +| Dimension (W x D x H) | 3.9 x 7.1 x 1.6 inch | +| Maximum Output Power | +3.3V: 12A<br>+5V: 15A<br>+12V: 41A<br>-12V: 0.2A<br>+5Vsb: 3A | +| Rated Input Voltage/Current | 100-240Vac / 6.6A max | +| Rated Input Frequency | 50-60HZ | +| Inrush current | Less than 30A | + +### 2.2.9 Thermal + +Active cooling with up to 6 fans is integrated in the chassis. + +The hardware acceleration cards described in Section 2.2.3.2 use passive cooling and a custom heatsink and is equipped with temperature sensors. It is designed to operate in temperatures ranging from -5°C to +55°C. + +### 2.2.10 Environmental and Regulations + +The O-DU<sub>8</sub> hardware system is RoHS Compliant. The power supply unit is EMC FCC/CISPR Class B compliant. Table 2-10 lists the environmental related features and parameters. + +**Table 2-10: Environmental Features** + +| Item Name | Description | +|---------------------------------|----------------------------| +| Operating Temperature | -5°C to +55°C | +| Non-operating Temperature | -40°C to 70°C | +| Operating Relative Humidity | 8% to 90% (non-condensing) | +| Non-operating Relative Humidity | 5% to 95% (non-condensing) | + +The hardware accelerator described in Section 2.2.3.2 is designed to operate in indoor environments and in temperatures ranging from -5°C to +55°C. + +## 2.3 O-RU<sub>8</sub> Hardware Reference Design + +In this section we describe, the HW reference design of all O-RU<sub>8</sub> components including block diagram, HW components, synchronization and timing, mechanical design, power supply, thermal, and environment requirements. + +### 2.3.1 O-RU<sub>8</sub> High-Level Functional Block Diagram + +Figure 2-15 provides a high-level functional block diagram depicting the major HW/SW components. It also highlights the internal/external interfaces that are required. This document shows how to implement the system defined by the IPC-HAR [6] document. + +![Figure 2-15: High-Level Functional Block Diagram of O-RU8. The diagram shows the internal components of an O-RU8 enclosed in a dashed box. The components are: CPRI (connected to O-RAN FH and To/From O-DU8), Digital Processing Unit, RF Processing Unit, Timing Unit, and Power Unit. The CPRI, Digital Processing Unit, and RF Processing Unit are connected in a chain. The Timing Unit provides local timing from CDR to the CPRI and Digital Processing Unit, and local timing from GNSS or equivalent to the RF Processing Unit. The Power Unit provides power to the Timing Unit, Digital Processing Unit, and RF Processing Unit.](abd162c549e12557d1c0845637aba4bc_img.jpg) + +``` + +graph LR + subgraph O-RU8 + CPRI[CPRI] <--> DPU[Digital Processing Unit] + DPU <--> RPU[RF Processing Unit] + TU[Timing Unit] + PU[Power Unit] + GNSS[GNSS optional] + + CPRI -- "Local timing from CDR" --> TU + GNSS -- "Local timing from GNSS or equivalent" --> TU + PU --> TU + PU --> DPU + PU --> RPU + end + O-RAN-FH[O-RAN FH] <--> CPRI + CPRI <--> ToFromODU8[To/From O-DU8] + +``` + +Figure 2-15: High-Level Functional Block Diagram of O-RU8. The diagram shows the internal components of an O-RU8 enclosed in a dashed box. The components are: CPRI (connected to O-RAN FH and To/From O-DU8), Digital Processing Unit, RF Processing Unit, Timing Unit, and Power Unit. The CPRI, Digital Processing Unit, and RF Processing Unit are connected in a chain. The Timing Unit provides local timing from CDR to the CPRI and Digital Processing Unit, and local timing from GNSS or equivalent to the RF Processing Unit. The Power Unit provides power to the Timing Unit, Digital Processing Unit, and RF Processing Unit. + +**Figure 2-15: High-Level Functional Block Diagram** + +### 2.3.2 O-RU<sub>8</sub> Hardware Components + +General block diagrams for 2T2R and 4T4R O-RU<sub>8</sub> examples are shown. + +Figure 2-16 shows a 2T2R implementation and Figure 2-17 shows an 4T4R implementation. In each of these diagrams, the Digital Processing Unit is further detailed in 2.3.2.1. Items under the umbrella of RF + +1 Processing Unit, including the Transceiver, RFFE and other RF items are reviewed in additional detail in +2 2.3.2.2. Clock and Synchronization are reviewed in 2.3.3. The Power Unit is detailed in 2.3.6. + +![Figure 2-16: 2T2R General Block Diagram with TR switch. This block diagram illustrates the architecture of a 2T2R (2 Transmit, 2 Receive) system. On the left, a 'Digital Processing Unit' (DPU) is connected to a 'Clock' and a 'Synchronizer'. The DPU has control lines for 'TR control', 'Tx enable', and 'Rx enable'. It interfaces with a 'Transceiver' block via 'SERDES' and 'SPI' signals. The 'Transceiver' is connected to a 'Power Unit'. The 'Transceiver' output is split into two paths: one for 'Tx0' and 'Tx1' (transmit) and one for 'Rx0' and 'Rx1' (receive). Each path includes a 'bypass' switch, an 'RFFE' (Radio Frequency Front-End) block, and a 'PA' (Power Amplifier) block. The outputs of the PAs are connected to 'Port A' via matching networks and ground connections.](3029b0b1ca7d9eabded25d7d283f6f21_img.jpg) + +Figure 2-16: 2T2R General Block Diagram with TR switch. This block diagram illustrates the architecture of a 2T2R (2 Transmit, 2 Receive) system. On the left, a 'Digital Processing Unit' (DPU) is connected to a 'Clock' and a 'Synchronizer'. The DPU has control lines for 'TR control', 'Tx enable', and 'Rx enable'. It interfaces with a 'Transceiver' block via 'SERDES' and 'SPI' signals. The 'Transceiver' is connected to a 'Power Unit'. The 'Transceiver' output is split into two paths: one for 'Tx0' and 'Tx1' (transmit) and one for 'Rx0' and 'Rx1' (receive). Each path includes a 'bypass' switch, an 'RFFE' (Radio Frequency Front-End) block, and a 'PA' (Power Amplifier) block. The outputs of the PAs are connected to 'Port A' via matching networks and ground connections. + +Figure 2-16: 2T2R General Block Diagram with TR switch + +![Figure 2-17: 4T4R General Block Diagram with TR switch. This block diagram illustrates the architecture of a 4T4R (4 Transmit, 4 Receive) system. It follows a similar structure to Figure 2-16 but with four parallel paths. The 'Digital Processing Unit' (DPU) is connected to a 'Clock' and a 'Synchronizer'. It interfaces with a 'Transceiver' block via 'SERDES' and 'SPI' signals. The 'Transceiver' is connected to a 'Power Unit'. The 'Transceiver' output is split into four paths: two for 'Tx0' and 'Tx1' (transmit) and two for 'Rx0' and 'Rx1' (receive). Each path includes a 'bypass' switch, an 'RFFE' (Radio Frequency Front-End) block, and a 'PA' (Power Amplifier) block. The outputs of the PAs are connected to 'Port A' via matching networks and ground connections.](e8062f67aaf4d75b898bb8b69480ce2f_img.jpg) + +Figure 2-17: 4T4R General Block Diagram with TR switch. This block diagram illustrates the architecture of a 4T4R (4 Transmit, 4 Receive) system. It follows a similar structure to Figure 2-16 but with four parallel paths. The 'Digital Processing Unit' (DPU) is connected to a 'Clock' and a 'Synchronizer'. It interfaces with a 'Transceiver' block via 'SERDES' and 'SPI' signals. The 'Transceiver' is connected to a 'Power Unit'. The 'Transceiver' output is split into four paths: two for 'Tx0' and 'Tx1' (transmit) and two for 'Rx0' and 'Rx1' (receive). Each path includes a 'bypass' switch, an 'RFFE' (Radio Frequency Front-End) block, and a 'PA' (Power Amplifier) block. The outputs of the PAs are connected to 'Port A' via matching networks and ground connections. + +Figure 2-17: 4T4R General Block Diagram with TR switch + +In following section, we describe their functionality, interfaces and performance of every block in the RF Processing Unit. Since device integration is an ongoing activity, chip boundaries may be fluid and some functionalities may move from one block to another or entire functionalities may be absorbed into other blocks. The sections below describe the functional blocks independent of which physical device they may reside in. + +#### 2.3.2.1 Digital Processing Unit + +The digital processing unit of O-RU<sub>8</sub> is mainly for performing tasks related to FH interface, RF interface, and OAM. + +##### i. FPGA Solution Design 1 + +The digital processing unit of O-RU<sub>8</sub> is mainly for performing FH interface, RF interface, and OAM functions. + +##### a. FPGA Requirement + +The following items are the main requirement for the O-RU<sub>8</sub>: + +- Interface requirement: One lane of bi-direction SerDes targeting CPRI will be @10Gbps for FH split option 8. Four lanes of bi-direction JESD204B SerDes will be used for 2T2R. Eight lanes of bi-direction JESD204B SerDes will be used for 4T4R +- Resource requirement: FPGA resource requirements for 2T2R and 4T4R are shown in Table 2-11 and Table 2-12. + +**Table 2-11: Resource requirement for 2T2R O-RU<sub>8</sub>** + +| Module | FF | LUT | BRAM18 | DSP | +|-----------------|-------|-------|--------|-----| +| DUC | 4820 | 4346 | 0 | 108 | +| DDC | 4820 | 4346 | 0 | 108 | +| CFR | 11470 | 6136 | 22 | 36 | +| DPD | 34269 | 13250 | 188 | 87 | +| JESD204B | 4314 | 4285 | 0 | 0 | +| Fronthaul(CPRI) | 4210 | 2756 | 1 | 0 | +| Other | 8000 | 5000 | 100 | 12 | +| Total | 71903 | 40119 | 311 | 351 | + +**Table 2-12: Resource requirement for 4T4R O-RU<sub>8</sub>** + +| Module | FF | LUT | BRAM18 | DSP | +|--------|-------|-------|--------|-----| +| ChFIR | 2832 | 2686 | 0 | 84 | +| DUC | 5148 | 3756 | 0 | 36 | +| CFR | 25676 | 12372 | 48 | 96 | +| DPD | 45770 | 17643 | 217 | 105 | + +| | | | | | +|----------|--------|-------|-----|-----| +| AGC | 1000 | 600 | 4 | 8 | +| DDC | 1716 | 1252 | 0 | 12 | +| UL_ChFIR | 2832 | 2686 | 0 | 84 | +| JESD2048 | 9900 | 11127 | 0 | 0 | +| CPRI | 10080 | 8960 | 32 | 0 | +| Total | 104954 | 61082 | 301 | 425 | + +- Processor requirement: For device model A, the processor will be used, one is used for device control and management plane functions, the other one is for Digital Pre-Distortion (DPD) feedback path. For device model C, dual-core ARM cortex-A53 will be used, similarly one is used for device control and management plane functions, the other one is for DPD feedback path. +- Power requirement: Power estimations for 2T2R and 4T4R are shown in Figure 2-18 and Figure 2-19. + +![Figure 2-18: Power estimation for 2T2R O-RU8. The figure shows a summary of power and thermal data, and detailed on-chip power and power supply information.](467e3a1c2953c2837cea9288ecb9b087_img.jpg) + +**Summary** + +| | | +|-------------------------|------------| +| Total On-Chip Power | 7.445 W | +| Junction Temperature | 100.0 °C | +| Thermal Margin | 0.0°C 0.0W | +| Effective $\Theta_{JA}$ | 3.7 °C/W | + +Power distribution: 12% Transceiver, 0% I/O, 61% PS+FPGA Dyn., 27% Device Static, 0.000W Power supplied to off-chip devices. + +**On-Chip Power** + +| Resource | Power (W) | (%) | +|----------|-----------|-----| +| CLOCK | 0.923 | 12 | +| LOGIC | 1.778 | 24 | +| BRAM | 1.185 | 16 | +| DSP | 0.681 | 9 | +| PLL | 0.000 | 0 | + +**Power Supply** + +| Source | Voltage | Total (A) | +|-----------------------|---------|-----------| +| V <sub>CCINT</sub> | 1.000 | 5.691 | +| V <sub>CCBRAM</sub> | 1.000 | 0.145 | +| V <sub>CCAUX</sub> | 1.800 | 0.127 | +| V <sub>CCAUX_IO</sub> | 2.000 | | +| V <sub>CCD</sub> 3.3V | 3.300 | | +| V <sub>CCD</sub> 2.5V | 2.500 | | + +Figure 2-18: Power estimation for 2T2R O-RU8. The figure shows a summary of power and thermal data, and detailed on-chip power and power supply information. + +Figure 2-18: Power estimation for 2T2R O-RU<sub>8</sub> +![Figure 2-19: Power estimation for 4T4R O-RU8. The figure shows a summary of power and thermal data, and detailed on-chip power and power supply information.](8947feeb3ee16e761b9a2dc6ea12edba_img.jpg) + +**Summary** + +| | | +|-------------------------|------------| +| Total On-Chip Power | 8.0 W | +| Junction Temperature | 100.0 °C | +| Thermal Margin | 0.0°C 0.0W | +| Effective $\Theta_{JA}$ | 1.0 °C/W | + +Power distribution: 21% Transceiver, 0% I/O, 50% PS+FPGA Dyn., 29% Device Static, 0.000W Power supplied to off-chip devices. + +**On-Chip Power** + +| Resource | Power (W) | (%) | +|----------|-----------|-----| +| CLOCK | 0.505 | 6 | +| LOGIC | 2.061 | 26 | +| BRAM | 0.264 | 3 | +| DSP | 1.174 | 15 | + +**Power Supply** + +| Source | Voltage | Total (A) | +|-----------------------|---------|-----------| +| V <sub>CCINT</sub> | 0.720 | 7.981 | +| V <sub>CCINT_IO</sub> | 0.850 | 0.072 | +| V <sub>CCBRAM</sub> | 0.850 | 0.087 | +| V <sub>CCAUX</sub> | 1.800 | 0.284 | + +Figure 2-19: Power estimation for 4T4R O-RU8. The figure shows a summary of power and thermal data, and detailed on-chip power and power supply information. + +Figure 2-19: Power estimation for 4T4R O-RU<sub>8</sub> + +- Speed grade, environmental requirement: -2L, 0°C to 110°C + +##### b. FPGA Design + +This solution of the digital processing unit incorporates FPGA and a processor. The FPGA handles high speed digital processing such as FH, DDC, DUC, CFR and so on. All functions are listed in the previous section. The processor is used for hardware device configuration and the OAM function. The FPGA and the processor core can be integrated into one SoC or implemented into two devices. Here the FPGA and the processor core are integrated into one SoC device. + +![Figure 2-20: FPGA Reference Design Diagram. The diagram shows a central 'FPGA' block containing a 'Processor'. To the left, 'DDR' is connected via 'MIG', 'Flash' via 'SPI', and 'Debug' via 'MII'. To the right, a 'Transceiver' is connected via 'JESD204B', a 'PLL' is connected via 'SPI' and provides clock signals (245.76MHz, 1.92MHz, 122.88MHz) to the FPGA, and an 'SFP+' is connected via 'IIC' and '10G SerDes'. A power supply block at the bottom lists: 'Power: 3.3V 2.5V 1.8V 1.35V 1.2V 0.9V'.](1d3df773fc06ac88ddc2bb46dbac0090_img.jpg) + +Figure 2-20: FPGA Reference Design Diagram. The diagram shows a central 'FPGA' block containing a 'Processor'. To the left, 'DDR' is connected via 'MIG', 'Flash' via 'SPI', and 'Debug' via 'MII'. To the right, a 'Transceiver' is connected via 'JESD204B', a 'PLL' is connected via 'SPI' and provides clock signals (245.76MHz, 1.92MHz, 122.88MHz) to the FPGA, and an 'SFP+' is connected via 'IIC' and '10G SerDes'. A power supply block at the bottom lists: 'Power: 3.3V 2.5V 1.8V 1.35V 1.2V 0.9V'. + +**Figure 2-20: FPGA Reference Design Diagram** + +For the processor portion, the internal RAM resource may not be enough. So the external DDR is needed to let the processor handle more RAM consuming functions such as operation system or stack protocols like Network Configuration Protocol (NetConf) Client. For the O-RU<sub>8</sub> design, the DDR3 with 256Mb\*16bit memory capacity is enough. The interface between the DDR and processor can be memory interface generator (MIG). The external Flash is used to store operation system related files, calibration information of the RF portion, NetConf related files, FPGA firmware and so on. For this O-RU<sub>8</sub> design, the flash with 2Gb memory capacity is enough. The online debug function is performed by external Ethernet PHY with an RJ45 connector. This allows the administrator to visit the internal function of the O-RU<sub>8</sub> and control it. The interface between the DDR and processor can be Media-Independent interface (MII). The Ethernet PHY device can be very general 100M Ethernet Transceiver. The FPGA has one SerDes lane connected to optical module to perform the fronthaul link between O-RU<sub>8</sub> and O-DU<sub>8</sub> /FHM<sub>8</sub>. Another 4 SerDes lanes of the FPGA are needed to connect one transceiver of the O-RU<sub>8</sub> to transmit or receive IQ sample by the interface of JESD204B while the FPGA needs synchronized clock signals to work well. The interface between PLL and FPGA should be Low-Voltage Differential Signaling (LVDS). + +#### 2.3.2.2 RF Processing Unit + +For the RF processing unit of O-RU<sub>8</sub>, it will perform functionalities of ADC, DAC, LO, down converter, up converter and etc. + +##### 2.3.2.2.1 Transceiver Reference Design + +For the O-RU<sub>8</sub> the sampling function and frequency conversion function can be performed by transceiver. The purpose of using the transceiver is to saving power and size of the PCB. The Transceiver is to convert between high speed baseband data and a low-level RF for both transmit and receive signal chain. In addition, the transceiver is responsible for orchestration of control signals not limited to the PA enable, LNA enable, LNA bypass as well as other required system level signals. + +###### a. Hardware Requirements + +Include the requirements for this component. + +- Interface Requirements: The interface requirements for the Transceivers are list in Table 2-13. + +**Table 2-13: Interface requirements of the Transceiver** + +| Item Name | Description | +|--------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| High Speed Data | High speed data represents the baseband information being transmitted or received. Depending on the configuration of the O-RAN device, various bandwidths may be supported leading to a range of payload rates. Options for data include parallel data paths, JESD204B and JESD204C. Up to 8 lanes in each direction may be supported although fewer is preferred. Options such as DPD and numeric precision will impact the payload rate. Several options are shown in the following table. All data represents IQ 16-bit (N=16) precision. Some devices support IQ 12 bit (N'=12) which may reduce the required data rates accordingly. The tables below assume 1 ORx for 2 TRx. From Table 2-14 and Table 2-15, the number of lanes required may be determined by dividing the total bit rates shown by the capacity of a lane, typically 12.5 GBPS for JESD204B and 25 GBPS for JESD204C. | +| Reference Clock (Device Clock) | The transceiver should receive a reference for internal clock and LO synthesis needs. This reference clock can function as the JESD204 Device Clock where the interface is by SERDES. The specific clock frequency is determined by the operation mode of the transceiver and may range from 1Hz upward. | +| SYSREF | If the transceiver supports SERDES, then it should accept a SYSREF signal from the clock or data source as appropriate. The number and configuration for the SYSREF is dependent on the operating mode of the transceiver. | +| SYNCB | If the transceiver supports SERDES, then it should also support a SYNCB for each link as appropriate. | +| Control | Control of the transceiver is by way of 3 or 4 wire SPI or IIC functioning as a slave. Support for 1.8V control is required and tolerance of 3.3V is preferred. The transceiver may optionally include a separate SPI master for control of peripheral devices as required. | +| GPIO | The transceiver may optionally include GPIO for controlling peripherals including but not limited to PAs, LNAs and other devices. These GPIOs should at a minimum support 1.8V outputs but the specifics will be determined by the connected devices. The GPIO should | + +| | | +|------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | also support input from peripheral devices. Input should at a minimum support 1.8V logic with tolerance of 3.3V preferred. | +| Tx Enable | The transceiver should provide an output to support enabling and disabling the external devices in the transmit chain such as a TxVGA (optional) and PA. | +| Rx Enable | The transceiver should provide an output to support enabling and disabling the external devices in the transmit chain such as a RF Front End Module or LNA. | +| LNA Bypass | The transceiver should provide an output to support bypassing the LNA appropriately in the condition of a large blocker if so required. | +| RF Outputs | RF outputs including the main Tx signal should support 50 ohm or 100 ohms signalling. These outputs can be either single ended or differential. | +| RF Inputs | RF inputs including the main Rx and the Observation Rx (ORx) (for DPD) should support 50 ohm or 100 ohms signalling. These inputs can be either single ended or differential. The device should support at least 1 ORx. | + +**Table 2-14: Payload with DPD in Digital Device (GBPS Rx/Tx)** + +| Bandwidth (MHz) | Parallel | JESD204B | JESD204C | Parallel | JESD204B | JESD204C | +|-----------------|------------|-------------|-------------|-------------|-------------|-------------| +| | 2T2R | | | 4T4R | | | +| <b>20</b> | 2.95/5.9 | 3.69/7.37 | 3.04/6.08 | 5.9/11.8 | 7.37/14.75 | 6.08/12.17 | +| <b>50</b> | 5.9/11.8 | 7.37/14.75 | 6.08/12.17 | 11.8/23.59 | 14.75/29.49 | 12.17/24.33 | +| <b>100</b> | 11.8/23.59 | 14.75/29.49 | 12.17/24.33 | 23.59/47.19 | 29.49/58.98 | 24.33/48.66 | + +**Table 2-15: Payload with DPD in Transceiver (GBPS Rx/Tx)** + +| Bandwidth (MHz) | Parallel | JESD204B | JESD204C | Parallel | JESD204B | JESD204C | +|-----------------|-----------|-----------|-----------|-------------|-------------|-------------| +| | 2T2R | | | 4T4R | | | +| <b>20</b> | 1.97/1.97 | 2.46/2.46 | 2.03/2.03 | 3.93/3.93 | 4.92/4.92 | 4.06/4.06 | +| <b>50</b> | 3.93/3.93 | 4.92/4.92 | 4.06/4.06 | 7.86/7.86 | 9.83/9.83 | 8.11/8.11 | +| <b>100</b> | 7.86/7.86 | 9.83/9.83 | 8.11/8.11 | 15.73/15.73 | 19.66/19.66 | 16.22/16.22 | + +- Algorithm Requirements: The transceiver is required to provide appropriate algorithms to sustain RF operation including but not limited to Rx AGC, Tx Power control. DPD and CFR may be included either in the transceiver or in the digital baseband device making the trade-offs in Payload shown in Table 2-11 and Table 2-12. +- Device Configuration: The transceiver should support either 2T2R or 4T4R. In addition, at least one ORx path should be supported. Additional ORx paths are allowed as required for the application. + +- Power Dissipation: Total dissipation of the TRx should be less than 6W for 4T4R. +- RF Specifications are given in Table 2-16 + +**Table 2-16: RF specifications in Transceiver** + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Conditions/Comments | +|-----------------------------------------------------------------------------------|--------|-----|--------|------|--------|----------------------------------------------------------------------------------------------------------------------------------------| +| TRANSMITTERS | | | | | | | +| Center Frequency | | 650 | | 6000 | MHz | | +| Transmitter Synthesis Bandwidth | | | | 450 | MHz | | +| Transmitter Large Signal Bandwidth | | | | 200 | MHz | | +| Transmitter Attenuation Power Control Range | | 0 | | 32 | dB | Signal-to-noise ratio (SNR) maintained for attenuation between 0 dB and 20 dB | +| Transmitter Attenuation Power Control Resolution | | | 0.05 | | dB | | +| Adjacent Channel Leakage Ratio (ACLR) | | | -66 | | dB | 20 MHz LTE at -12 dBFS<br>75 MHz < f ≤ 2800 MHz | +| In Band Noise Floor | | | -154.5 | | dBm/Hz | 0 dB attenuation; in band noise falls 1 dB for each dB of attenuation for attenuation between 0 dB and 20 dB<br>600 MHz < f ≤ 3000 MHz | +| Out of Band Noise Floor | | | -153 | | dBm/Hz | 0 dB attenuation; 3 × bandwidth/2 offset<br>600 MHz < f ≤ 3000 MHz | +| Maximum Output Power | | | 6 | | dBm | 0 dBFS, continuous wave tone into 50 Ω load, 0 dB transmitter attenuation<br>600 MHz < f ≤ 3000 MHz | +| Third Order Output Intermodulation Intercept Point | OIP3 | | 27 | | dBm | 0 dB transmitter attenuation<br>600 MHz < f ≤ 5700 MHz | +| Error Vector Magnitude (Third Generation Partnership Project (3GPP) Test Signals) | EVM | | 0.6 | | % | 50 kHz RF PLL loop bandwidth | +| 1900 MHz LO | | | 0.53 | | % | 300 kHz RF PLL loop bandwidth | +| 3800 MHz LO | | | | | | | +| OBSERVATION RECEIVER | | | | | | | +| Center Frequency | | 450 | | 6000 | MHz | | +| Gain Range | | | 30 | | dB | IIP3 improves decibel for decibel for the first 18 dB of gain attenuation; QEC performance optimized for 0 dB to 6 dB of | + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Conditions/Comments | +|---------------------------------------------------------------|-------------------|-----|-----------------------|------|---------------------|----------------------------------------------------------------------------------------------------------------------| +| Analog Gain Step | P <sub>HIGH</sub> | | 0.5 | | dB | attenuation only<br>For attenuator steps from 0 dB to 6 dB | +| Receiver Bandwidth | | | | 450 | MHz | | +| Maximum Useable Input Level | | | | | | 0 dB attenuation; increases decibel for decibel with attenuation; continuous wave corresponds to -1 dBFS at ADC | +| Integrated Noise | | | -11<br>-58.5<br>-57.5 | | dBm<br>dBFS<br>dBFS | 75 MHz < f ≤ 3000 MHz<br>450 MHz integration bandwidth<br>491.52 MHz integration bandwidth | +| Third-Order Input Intermodulation Intercept Point Narrow Band | IIP3 | | | | | Maximum observation receiver gain; test condition: P <sub>High</sub> - 11 dB/tone | +| 1900 MHz | | | 15 | | dBm | | +| 2600 MHz | | | 16.5 | | dBm | | +| 3800 MHz | | | 18 | | dBm | | +| Wide Band | | | | | | | +| 1900 MHz | IM3 | | 13 | | dBm | IM3 products > 130 MHz at baseband; test condition: P <sub>High</sub> - 11 dB/tone ; 491.52 MSPS | +| 2600 MHz | | | 11 | | dBm | | +| 38000 MHz | | | 13 | | dBm | | +| Third-Order Intermodulation Product | | | -70 | | dBc | 600 MHz < f ≤ 3000 MHz | +| Spurious-Free Dynamic Range | SFDR | | 64 | | dB | Non IMx related spurs, does not include HDx; (P <sub>HIGH</sub> - 11) dB input signal | +| Harmonic Distortion Second Order Harmonic Distortion Product | HD2 | | -80<br>-73 | | dBc<br>dBc | (P <sub>HIGH</sub> - 11) dB input signal<br>In band HD falls within ±100 MHz<br>Out of band HD falls within ±225 MHz | +| Third-Order Harmonic Distortion Product | HD3 | | -70<br>-65 | | dBc<br>dBc | In band HD falls within ±100 MHz<br>Out of band HD falls within ±225 MHz | +| RECEIVERS | | | | | | | +| Center Frequency | | | | 6000 | MHz | | +| Gain Range | | | 30 | | dB | | +| Analog Gain Step | | | 0.5 | | dB | Attenuator steps from 0 dB to 6 | + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Conditions/Comments | +|------------------------------------------------------|-------------------|-----|-----|-----|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Receiver Bandwidth<br>Maximum Useable<br>Input Level | $P_{\text{HIGH}}$ | | 1 | 200 | dB<br>MHz | dB<br>Attenuator steps from 6 dB to 30 dB<br>0 dB attenuation, increases decibel for decibel with attenuation; continuous wave = 1800 MHz; corresponds to -1 dBFS at ADC<br>75 MHz < f ≤ 3000 MHz | +| Noise Figure | NF | | 12 | | dB | 0 dB attenuation, at receiver port<br>600 MHz < f ≤ 3000 MHz | +| Input Third-Order<br>Intercept Point | IIP3 | | | | | | +| Difference Product,<br>2600 MHz (Wideband) | IIP3, d | | 17 | | dBm | Two ( $P_{\text{HIGH}} - 9$ ) dB tones near band edge | +| 2600 MHz (Midband) | | | 21 | | dBm | | +| Sum Product,<br>2600 MHz (Wideband_ | IIP3, s | | 20 | | dBm | Two ( $P_{\text{HIGH}} - 9$ ) dB tones, at bandwidth/6 offset from the LO | +| HD3 | HD3 | | | | | ( $P_{\text{HIGH}} - 6$ ) dB continuous wave tone at bandwidth/6 offset from the LO | +| | | | -66 | | dBc | 600 MHz < f ≤ 4800 MHz | + +1 +2 + +###### b. Hardware Design + +For the O-RU<sub>8</sub> the sampling function and frequency conversion function can be performed by transceiver. Usually the transceiver is integrated by ADC, DAC, LO, down converter, up converter and so on. The block diagram of transceiver design is shown in Figure 2-21. + +![Figure 2-21: Transceiver Reference Design Diagram. This block diagram illustrates the internal architecture of a transceiver. On the left, external inputs include REF Clock In, SYSREF, Ext. LO/Clock In, Rx1 through Rx4, Tx1 through Tx4, and ORx1 through ORx4. The core consists of a 'Clock, Synchronization & Synthesis' block, four 'Receiver Block' units (1-4), four 'Transmit Block' units (1-4), an 'Observation Receiver', and a 'JESD204B/C Serial Interface'. Each receiver and transmit block contains a mixer, an ADC or DAC, and associated processing blocks like Decimation, pFIR, AGC, Tuning, RSSI, and Overload Device Management. The 'Optional Features' section highlights the 'DPD Engine' and the 'Observation Receiver' block. On the right, external outputs include SCLK, CSB, SDO, SDIO, CPIO1 through CPIO#, SYNCIN, SERDES Out, SERDES In, and SYNC OUT.](98987e5c6fe062006042b349fcd85a83_img.jpg) + +Figure 2-21: Transceiver Reference Design Diagram. This block diagram illustrates the internal architecture of a transceiver. On the left, external inputs include REF Clock In, SYSREF, Ext. LO/Clock In, Rx1 through Rx4, Tx1 through Tx4, and ORx1 through ORx4. The core consists of a 'Clock, Synchronization & Synthesis' block, four 'Receiver Block' units (1-4), four 'Transmit Block' units (1-4), an 'Observation Receiver', and a 'JESD204B/C Serial Interface'. Each receiver and transmit block contains a mixer, an ADC or DAC, and associated processing blocks like Decimation, pFIR, AGC, Tuning, RSSI, and Overload Device Management. The 'Optional Features' section highlights the 'DPD Engine' and the 'Observation Receiver' block. On the right, external outputs include SCLK, CSB, SDO, SDIO, CPIO1 through CPIO#, SYNCIN, SERDES Out, SERDES In, and SYNC OUT. + +**Figure 2-21: Transceiver Reference Design Diagram (Optional elements are highlighted in Grey)** + +The definition of the input/output lines are as follows: + +- REF Clock In is the differential reference input to the on-chip synthesizer. This may also function as the SerDes Device Clock. +- SYSREF is a JESD204B/C differential synchronization signal. +- Ext LO/Clock Input is an optional input that can be used as an alternate LO or clocking signal. +- Rx1 through Rx4 are differential receiver inputs to their respective cores. +- Tx1 through Tx4 are differential transmitter output from their respective cores. +- ORx1 through ORx4 are differential observation receiver inputs. +- SCLK is the serial control clock input. +- CSB is the active low device select for the control interface. +- SDO is the serial data output for the control interface. This pin may be omitted for 3-pin control implementations. +- SDIO is a bidirectional serial data interface. In 4-pin mode, this pin functions as the serial data input. + +- GPIO1 – GPIO# are general purpose IO signals used for interrupts, enables, test mode and resets. These are used as interface and control for peripheral devices including controllers, TxVGAs, PA, LNA and similar devices where SPI control is too slow. +- SYNCIN are differential pins associated with the receiver channels of the JESD204 interface. In not used, they are typically grounded. Up to 4 pair may be supported. +- SerDes Out are differential JESD204B/C data output interfaces. Up to 8 lanes may be active. +- SerDes In are differential JESD204B/C data input interfaces. Up to 8 lanes may be active. +- SYNCOUT are differential pins associated with the transmitter channels of the JESD204 interface. If not used, do not connect. Up to 4 pair may be supported. + +##### 2.3.2.2.2 Power Amplifier (PA) Reference Design + +The Power Amplifier boosts the RF output to the level required for the base station class. + +###### a. Hardware Requirements + +The PA should have large enough gain to reduce the need for an additional driver. This will reduce cost and PCB space. The output power should be at least 27dBm (30dBm for 500mW/port to compensate for the loss of switch and antenna filter). The ACLR should be greater than 47dBc according to the related 3GPP test mode. DPD is needed to reduce the power consumption. The P1 dB requirement is closely related to the DPD algorithm. + +**Table 2-17: PA Requirements** + +| Frequency band | Band41 | Band78 | Additional Information | +|--------------------|--------|------------------------------|-------------------------------------------------------------------| +| Gain | >33dB | >33dB | | +| P3dB | >34dBm | >34dBm<br>>37dBm(500mW/port) | ACLR>=47dBc with<br>DPD@100MHz NR 27dBm<br>(30dBm for 500mW/port) | +| Input return loss | <-15dB | <-15dB | | +| Output return loss | <-15dB | <-15dB | | +| Switching Speed | <1us | <1us | | +| HD2 | >28dBc | >28dBc | CW 27dBm | +| HD3 | >30dBc | >30dBc | CW 27dBm | + +- Interface Requirements: + +The interface requirements of the transmit PA are listed in Table 2-18. + +**Table 2-18: Interface requirements of the transmit PA** + +| Item Name | Description | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Enable | The enable input should be compatible with 1.8V logic and tolerate 3.3V as required. A logic high enables the PA. A logic low disables the device and places it in a minimum dissipation mode. | +| RF Outputs | RF outputs support 50-ohm single ended to properly interface to a directional coupler, isolator, switch or antenna. | +| RF Inputs | RF inputs should support 50 ohm, single ended match to the transceiver output or preamp. | +| RF power detector | Power detector (optional) | + +- Power Dissipation: Dissipation while enabled should not exceed ~3W. + +###### b. Hardware Design + +$RF_{in}$ is the input to the PA, $RF_{out}$ is the output of the PA. $V_{cc}$ and $V_{bias}$ are the power inputs of the PA. PAEN is the control pin to disable or enable the PA. The input and output should match to 50 ohm as much as possible to reduce the reflection. $V_{cc}$ and $V_{bias}$ need capacitors to reduce the DC power ripples and give a short route to reduce the RF energy leakage. Figure 2-22 shows the details. + +![Figure 2-22: PA Reference Design Diagram. A schematic diagram of a Power Amplifier (PA) represented by a triangle. The input is labeled RFin, the output is labeled RFout, and the control input is labeled RFEN. The power supply is labeled Vcc.](2f6e32049c7c308d5cfadfeb4ddcfd24_img.jpg) + +Figure 2-22: PA Reference Design Diagram. A schematic diagram of a Power Amplifier (PA) represented by a triangle. The input is labeled RFin, the output is labeled RFout, and the control input is labeled RFEN. The power supply is labeled Vcc. + +**Figure 2-22: PA Reference Design Diagram** + +##### 2.3.2.2.3 Low Noise Amplifier (LNA) Reference Design + +The purpose of the LNA is to boost the Rx signal to a level that can nominally interface directly to the transceiver. This block will typically be a 2-stage amplifier with a 2<sup>nd</sup> stage bypass. The frontend will also include a TR switch to shunt any Tx signal to a termination away from the amplifier. + +###### a. Hardware Requirements + +The requirements of the LNA are listed here. + +- Interface Requirements: The interface requirements of the transmit LNA are listed in Table 2-19. + +**Table 2-19: One stage LNA Requirements** + +| Parameter | Band 41 | Band 78 | Additional Information | +|--------------------|---------|---------|------------------------| +| NF | <1dB | <1dB | | +| Gain | >15dB | >15dB | | +| P1dB | >18dBm | >18dBm | | +| Input return loss | <-12dB | <-12dB | | +| Output return loss | <-15dB | <-15dB | | +| Switching Speed | <1us | <1us | | +| IP3 | >30dBm | >30dBm | 2 Tone CW -15dBm | +| K | >1 | >1 | up to f = 12.5 GHz | +| Max input power | >15dBm | >15dBm | | + +- Device Configuration: Single or dual device. +- Power Dissipation: Less than 500 mW for a dual when device is fully enabled in receive mode. +- RF Specifications: For LNA unit, it should have larger enough gain to reduce extra driver amplifier for cost and PCB space. The NF figure of LNA should small enough to overcome the loss of switch and filter. + +**Table 2-20: Two stage LNA Requirements** + +| Frequency band | Band41 | Band78 | Additional Information | +|----------------|--------|--------|------------------------| +|----------------|--------|--------|------------------------| + +| | | | | +|--------------------|-------------------------------------------------|-------------------------------------------------|--------------------| +| NF | <1 dB | <1.5 dB | | +| Gain | High gain $\geq 32$ dB<br>Low gain $\geq 16$ dB | High gain $\geq 32$ dB<br>Low gain $\geq 16$ dB | | +| P1dB | >18dBm | >18dBm | | +| Input return loss | <-12dB | <-12dB | | +| Output return loss | <-15dB | <-15dB | | +| Switching Speed | <1us | <1us | | +| IP3 | >30dBm | >30dBm | 2 Tone CW -15dBm | +| K | >1 | >1 | up to f = 12.5 GHz | +| Max input power | >15dBm | >15dBm | | + +###### b. Hardware Design + +The reference designs for one stage LNA and two-stage LNA are given. + +###### - One stage LNA + +RFin is the input port of the LNA. RFout is the output of the LNA. Vcc is the power input of the LNA. LNA EN is the control pin to disable or enable the LNA. The input match to 50 ohm as much as possible to reduce the reflection. But for output of the LNA, it is hard to get best Noise figure and the output return loss. Compromise is needed between NF and return loss. Usually the return loss should be around -10dB or -12dB. Also is should be very careful to assure the stability of the LNA in a large bandwidth. Vcc needs capacitors to reduce the DC power ripples and give a short route to reduce the RF energy leakage. Figure 2-23 shows the details. + +![Figure 2-23: One Stage LNA Diagram. A schematic diagram of a one-stage Low Noise Amplifier (LNA). It features a central triangular symbol representing the LNA core. The input port is labeled 'RFin' and the output port is labeled 'RFout'. A power supply pin labeled 'Vcc' is connected to the top of the LNA core. A control pin labeled 'LNAEN' is connected to the bottom of the LNA core.](d08ee9467c8570a17fb6b3c1b67b23d3_img.jpg) + +Figure 2-23: One Stage LNA Diagram. A schematic diagram of a one-stage Low Noise Amplifier (LNA). It features a central triangular symbol representing the LNA core. The input port is labeled 'RFin' and the output port is labeled 'RFout'. A power supply pin labeled 'Vcc' is connected to the top of the LNA core. A control pin labeled 'LNAEN' is connected to the bottom of the LNA core. + +Figure 2-23: One Stage LNA Diagram + +###### - Two stage LNA + +RFin is the input port of the LNA. RFout is the output of the LNA. Vcc is the power input of the LNA. LNA EN is the control pin to disable or enable the LNA. The input matches to 50 ohm as much as possible to reduce the reflection. But for output of the LNA, it is hard to get best Noise figure and the output return loss. Compromise is needed between NF and return loss. Usually the return loss should be around -10dB or -12dB. Also is should be very careful to assure the stability of the LNA in a large bandwidth. Vcc needs capacitors to reduce the DC power ripples and give a short route to reduce the RF energy leakage. Figure 2-24 shows the details. + +![Figure 2-24: Two-Stage LNA Diagram. The diagram shows two cascaded LNA stages. The first stage has an input RFin, a control pin LNAEN, and a bypass pin LNAbypass. Its output is connected to the input of the second stage. Both stages are powered by Vcc. The final output is RFout.](4a053f63b2da99d01eb4d4be8976f48c_img.jpg) + +Figure 2-24: Two-Stage LNA Diagram. The diagram shows two cascaded LNA stages. The first stage has an input RFin, a control pin LNAEN, and a bypass pin LNAbypass. Its output is connected to the input of the second stage. Both stages are powered by Vcc. The final output is RFout. + +Figure 2-24: Two-Stage LNA Diagram + +##### 2.3.2.2.4 RF Switch Reference Design + +For TDD use, the TX and RX links work spiritedly by time duplex. The switch is used to change the RF link according to the TDD duplex. In the TDD TX mode, the switch is switched to connect PA and antenna. In TDD RX mode, the switch is switched to LNA and antenna. + +###### a. Hardware Requirements + +The requirements of the RF switch are listed here. + +###### - Interface Requirements + +The interface requirements of the switch are listed in Table 2-21. + +Table 2-21: Interface requirements of the RF switch + +| Item Name | Description | +|-----------|----------------------------------------------------------------------------------------------------------| +| Control | Control the switch working mode | +| RF COM | The port connected to the antenna<br>RF inputs should support 50 ohm, single ended to match the antenna. | + +| | | +|------------|--------------------------------------------------------------------------------------------------------| +| RF Outputs | The port connected to the LNA.<br>RF inputs should support 50 ohm, single ended to match the LNA. | +| RF Inputs | The port connected to the PA.<br>RF inputs should support 50 ohm, single ended to match the PA output. | + +###### - RF Specifications + +For switch, it should have larger P1dB to not degrade the ACLR or damage the switch itself. The output power should be at least 26dBm (29dBm for 500mW/port) count on the loss of antenna filter so it must have low loss. Also the isolation needs to be high to protect the LNA. Higher HD2 and HD3 are needed to reduce the out of band emissions. + +**Table 2-22: RF Switch Requirements** + +| Frequency band | Band 41 | Band 78 | Additional Information | +|--------------------|---------|------------------------------|------------------------| +| Loss | <0.8dB | <0.8dB | | +| P1dB | >36dBm | >36dBm<br>>39dBm(500mW/port) | | +| Input return loss | <-15dB | <-15dB | | +| Output return loss | <-15dB | <-15dB | | +| Switching Speed | <1us | <1us | | +| Isolation | >30dB | >30dB | | +| HD2 | >70dBc | >70dBc | CW 27dBm | +| HD3 | >70dBc | >70dBc | CW 27dBm | + +###### **b. Hardware Design** + +RF Com is the input port of the switch, also can be the output of the switch. RF in is the input of the switch. RF out is the output of the switch. Control 1 and control 2 are the control pin to switch the RFin to RF Com or from RF Com to RF out. Figure 2-25 shows the details. + +![RF Switch Reference Design Diagram](371a0270f778d956e7e1034ede54eb86_img.jpg) + +The diagram illustrates an RF switch reference design. It features a central square block with five ports. On the left side, there are two ports labeled 'RFin' (top) and 'RFout' (bottom). On the top and bottom sides, there are control ports labeled 'Control1' (top) and 'Control2' (bottom). On the right side, there is a port labeled 'RF com'. A diagonal line connects the 'RFin' port to the 'RF com' port, representing the internal switch mechanism. + +RF Switch Reference Design Diagram + +**Figure 2-25: RF Switch Reference Design Diagram** + +##### 2.3.2.2.5 Antenna Reference Design + +The antenna is used to radiate the TX power on to the air and receive the RX power from the air. For indoor Picocell scenario, the isotropic antenna is the first choice. + +###### a. *Hardware Requirements* + +The following table shows the antenna requirement for the O-RU<sub>8</sub>. + +**Table 2-23: Antenna Requirements** + +| Frequency band | Band 41 | Band 78 | +|-------------------------------------------|-----------------|-----------------| +| VSWR | $\leq 1.8$ | $\leq 1.8$ | +| Power capacity | $\geq 1$ W | $\geq 2$ W | +| Gain | $\geq 2$ dBi | $\geq 2.5$ dBi | +| Beam width on vertical direction | $\geq 35^\circ$ | $\geq 35^\circ$ | +| pattern roundness on horizontal direction | $\pm 3$ dB | $\pm 3$ dB | + +###### b. *Hardware Design* + +One possible choice of the isotropic antenna is the whip antenna. Following figure shows a design of one kind of whip antenna. + +![A technical drawing of a whip antenna, showing a long, thin, cylindrical body with a small circular base and a small circular top. A dashed line runs vertically through the center of the body.](dbacf0cc890892d4d8b8a0cbd5b46c81_img.jpg) + +A technical drawing of a whip antenna, showing a long, thin, cylindrical body with a small circular base and a small circular top. A dashed line runs vertically through the center of the body. + +**Figure 2-26: Whip Antenna** + +### 2.3.3 Synchronization and Timing + +The purpose of the Clocking device is to accept the network reference clock, typically 1 PPS, and generate a jitter free reference clock(s) for other devices in the system including the RF transceiver and digital block. The clock is typically + +- 1 part of an IEEE 1588 implementation either controlled by an external stack or implemented in the clock device itself +- 2 which could be part of the baseband implementation. + +##### *a. Hardware Requirements* + +Hardware requirements are: + +- Interface Requirements: The interface requirements of the transmit Clocking are listed in Table 2-24. + +**Table 2-24: Interface requirements of the clocking** + +| Item Name | Description | +|-----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Clock Input | The clock device should receive a network reference clock from the FPGA/ASIC. This typically could be a 1pps, 10 MHz or other standard reference as determined by the specific implementation. More than one input is allowed that may be selected between when the reliability of one reference is compromised. Standard differential clocking should be used to preserve signal integrity. | +| Control | Control of the transceiver is by way of 3 or 4 wire SPI or IIC functioning as a slave. Support for 1.8V control is required and tolerance of 3.3V is preferred. Typically, the clock devices will be part of an IEEE1588v2 protocol loop controlled by way of this control interface or other GPIO lines as required by the hardware implementation. | +| Clock Outputs | One or more clock outputs are required to drive the digital device and transceiver clock inputs. Each output should be independently programmable in frequency to suit the application. The outputs should nominally be differential to preserve clocking edge and to maximize tolerance of high common mode signals. | +| RF Inputs | RF inputs should support 50 ohm or 100 ohms, single ended or differential signalling to match the transceiver output. | + +- Power Dissipation: Total dissipation should be about less than 2W. +- RF Specifications: Clocking RF requirements are given in the following table. + +**Table 2-25: Clocking RF requirements** + +| Absolution Phase Noise, Dual Loop Mode - LVDS OUTPUT | Typical | Additional Information | +|------------------------------------------------------|-------------|----------------------------------------------------------------------------------------------------------------------------------------------------------| +| $f_{\text{OUT}} = 122.88\text{ MHz}$ | | Example is using an external 122.88 MHz VCXO (Crystek CVHD-950); reference = 122.88 MHz; channel divider = 10 or 1; PLL2 loop bandwidth (LBW) = 450 kHz. | +| 10 Hz Offset | -86 dBc/Hz | | +| 100 Hz Offset | -106 dBc/Hz | | +| 1 kHz Offset | -126 dBc/Hz | | +| 10 kHz Offset | -135 dBc/Hz | | +| 100 kHz Offset | -139 dBc/Hz | | +| 800 kHz Offset | -147 dBc/Hz | | + +| | | | +|------------------------------------------------------|-------------|------------------------------------------------------------------------------------------------------------------------------------------| +| 1 MHz Offset | −148 dBc/Hz | | +| 10 MHz Offset | −157 dBc/Hz | | +| 40 MHz Offset | −158 dBc/Hz | | +| Absolute Phase Noise, Single Loop Mode – LVDS OUTPUT | Typical | | +| LVDS OUTPUT | | | +| $f_{OUT} = 122.88 \text{ MHz}$ | | Example is using an external 122.88 MHz reference (SMA100A generator); reference = 122.88 MHz; channel divider = 10; PLL2 LBW = 450 kHz. | +| 10 Hz Offset | −111 dBc/Hz | | +| 100 Hz Offset | −113 dBc/Hz | | +| 1 kHz Offset | −123 dBc/Hz | | +| 10 kHz Offset | −135 dBc/Hz | | +| 100 kHz Offset | −140 dBc/Hz | | +| 800 kHz Offset | −147 dBc/Hz | | +| 1 MHz Offset | −148 dBc/Hz | | +| 10 MHz Offset | −157 dBc/Hz | | +| 40 MHz Offset | −157 dBc/Hz | | +| CLOCK OUTPUT ADDITIVE TIME JITTER (BUFFER MODE) | Typical | Example is using an external 122.88 MHz source driving VCXO inputs (distribution section only, does not include PLL and VCO) | +| $f_{OUT} = 122.88 \text{ MHz}$ | 79 fS | Integrated BW = 200 kHz to 5 MHz | +| | 101 fS | Integrated BW = 200 kHz to 10 MHz | +| | 140 fS | Integrated BW = 12 kHz to 20 MHz | +| | 187 fS | Integrated BW = 10 kHz to 40 MHz | +| | 189 fS | Integrated BW = 1 kHz to 40 MHz | +| | 176 fS | Integrated BW = 1 MHz to 40 MHz | + +1 + +2 + +#### b. Hardware Design + +For the clocking function, it is usually performed by a synchronization IC which may include one or more PLLs. And it also can supply numbers of output port to support different frequency clocking. + +![Figure 2-27: PLL Reference Design Diagram. This block diagram illustrates the internal architecture of a PLL reference design. It features two main PLL blocks, PLL 1 and PLL 2. PLL 1 takes differential reference inputs REFA and REFB, selected by REF_SEL, and processes them through 10-bit dividers, a switch-over control, a lock detector, a loop filter, a PFD, and a charge pump to generate a VCXO signal. PLL 2 takes a SYSREF input and processes it through a similar path to generate a VCO signal. Both PLLs are connected to an external VCXO via VCXO_VT and VCXO_IN pins. The VCO signal is divided and used to generate multiple output clocks (OUT0 to OUT13) through a series of dividers and delay blocks. The diagram also shows control and status pins: SDIO, SDO, SCLK, RST, RESET, Status_0,1/SP0,1, and SYSREF_IN (CMOS).](3490b7a94521a5e9a050c21ffd85df4a_img.jpg) + +Figure 2-27: PLL Reference Design Diagram. This block diagram illustrates the internal architecture of a PLL reference design. It features two main PLL blocks, PLL 1 and PLL 2. PLL 1 takes differential reference inputs REFA and REFB, selected by REF\_SEL, and processes them through 10-bit dividers, a switch-over control, a lock detector, a loop filter, a PFD, and a charge pump to generate a VCXO signal. PLL 2 takes a SYSREF input and processes it through a similar path to generate a VCO signal. Both PLLs are connected to an external VCXO via VCXO\_VT and VCXO\_IN pins. The VCO signal is divided and used to generate multiple output clocks (OUT0 to OUT13) through a series of dividers and delay blocks. The diagram also shows control and status pins: SDIO, SDO, SCLK, RST, RESET, Status\_0,1/SP0,1, and SYSREF\_IN (CMOS). + +**Figure 2-27: PLL Reference Design Diagram** + +REFA and REFB are differential reference clock inputs from the source to be cleaned up and used as the system reference. REF\_SEL is the control pin used to select between REFA and REFB signals. LF1 is PLL1 external loop filter. VCXO\_VT is the VCXO control voltage. This pin is connected to the voltage control pin of the external VCXO. VCXO\_IN are differential signals from the external VCXO. These typically can be configured for single ended operation as well. LF2\_CAP is the external loop filter capacitor for loop 2. This cap is connected between this pin and LDO\_VCO pin. LDO\_VCO is the on-chip LDO regular decoupling for the VCO. RESET(bar) is an active low pin to reset the internal logic to their default states. CS(bar) is an active low chip select for serial control. SCLK/SCL is a serial control port clock for both SPI and I2C. SDIO/SDA is a bidirectional serial data pin for both SPI and I2C. SDO is the serial data out pin for 4-wire mode. OUT0 through OUT13 are differential programmable output clock signals. These are the primary outputs of this device and provide high performance clock signals to the transceiver, baseband device and other key elements. This device is also responsible for providing SYSREF to various devices in the system if required. It may also use an external SYSREF as a source that may be retimed for local timing if necessary. STATUS0/SP0 is a lock detect and other status signal. STATUS1/SP1 is a lock detect and other status signal. SYSREF\_IN is an external SYSREF input clock is a differential input representing the JESD204 synchronization from the external source. + +### 2.3.4 External Interface Ports + +#### a. Hardware Requirements + +The following table shows the external ports or slots provided by O-RU<sub>8</sub>. + +**Table 2-26: External Port List** + +| Port Name | Feature Description | +|---------------------|---------------------------------------| +| Fronthaul interface | One 10Gbps SFP+ transceiver interface | +| | Or one RJ45 Ethernet interface | +| Debug interface | RJ45 for debug usage | +| Power interface | Two-pin male plug for power cable | + +#### b. Hardware Design + +- SFP+ case and connector: The SFP+ case and connector are standardized component on the market; following figure describe the form factor of one SFP case which is integrated with connector. + +![A 3D perspective drawing of an SFP+ (Small Form-factor Pluggable Plus) module. It is a rectangular component with a gold-plated edge connector on one side and a series of circular ports on the top surface. The drawing shows the internal structure and the mounting points for the connector.](7caf956840f46865f405b843ab93a5ff_img.jpg) + +A 3D perspective drawing of an SFP+ (Small Form-factor Pluggable Plus) module. It is a rectangular component with a gold-plated edge connector on one side and a series of circular ports on the top surface. The drawing shows the internal structure and the mounting points for the connector. + +**Figure 2-28: SFP+ case and connector** + +- RJ45 Ethernet interface: The RJ45 Ethernet interface is standardized component on the market; following figure describe the form factor of one RJ45 interface. + +![Isometric drawing of an RJ45 Ethernet interface connector.](038c6ed5ad6cd46597b1d01007c21f71_img.jpg) + +An isometric line drawing of an RJ45 Ethernet interface connector. It shows the standard 8-pin modular plug with a latch on the side and a shielded backshell. + +Isometric drawing of an RJ45 Ethernet interface connector. + +**Figure 2-29: RJ45 interface** + +### 2.3.5 Mechanical + +The shell of O-RU<sub>8</sub> is showing in the following figure. The O-RU<sub>8</sub> should be quiet, so it depends on the natural heat dissipation method. Usually the bottom of the shell is built by metal. All hot component should make its surfaces contact to metal shell through thermal pad. + +![Mechanical diagram of the O-RU8 shell showing dimensions.](ce4f8b5862c67a6b5b44ef5dc68f62ee_img.jpg) + +A 3D perspective mechanical drawing of the O-RU + +<sub>8</sub> + +shell. The shell is a square box with rounded corners and a top surface covered in a circular pattern of small holes for ventilation. The bottom edge features a series of vertical fins for heat dissipation. Dimension lines indicate the following measurements: the top width is 229, the depth is 229, and the height of the shell is 68.5. + +Mechanical diagram of the O-RU8 shell showing dimensions. + +**Figure 2-30: O-RU<sub>8</sub> Shell Mechanical Diagram** + +### 2.3.6 Power Unit + +For Picocell, for the power solution of the O-RU<sub>8</sub> can be over Ethernet cable (cat5E, cat6A) by POE (POE+, POE++) or directly power cable with fibre. And for the board power solution, LDO and DCDC can be used. + +#### a. Hardware Requirements + +For PA unit, it should have larger enough gain to reduce extra driver amplifier for cost and PCB space. The output power should be at least 27dBm count on the loss of switch and antenna filter. The ACLR should larger than 47dBc according to the related 3GPP test mode. To reduce the power consumption, DPD is needed. And the P1 dB requirement is closely related to the DPD algorithm. + +**Table 2-27: Power unit requirement for 2T2R and 4T4R O-RU<sub>8</sub>** + +| Module | Power consumption | | | | +|-------------------------------------|-------------------|-------|------|--------------------------------| +| | 2T2R | 4T4R | Unit | | +| FPGA | 8 | 9 | W | | +| Transceiver | 5.74 | 11.48 | W | | +| PLL | 1.78 | 1.78 | W | | +| PA | 5 | 10 | W | 0.75 TDD ratio | +| LAN | 0.15 | 0.3 | W | 0.25 TDD ratio | +| Ethernet PHY | 1 | 1 | W | | +| DDR | 0.9 | 0.9 | W | | +| Flash | 0.1 | 0.1 | W | | +| others | 1.65 | 1.65 | W | | +| component total power consumption | 24.3 | 36.2 | W | | +| O-RU <sub>8</sub> power consumption | 28.6 | 42.6 | W | on board power efficiency 0.85 | + +**Table 2-28: Power unit function** + +| Function | Priority | | +|----------------|-----------|----------------------------------------------------| +| Enable/Disable | Mandatory | | +| Power good | Optional | | +| Input voltage | Mandatory | 48V | +| Output voltage | Mandatory | 0.85V 1.2V 1.3V 1.5V 1.8V<br>2.5V 3.3V 5V 12V etc. | + +#### **b. Hardware Design** + +The block diagram of POE reference design is shown in Figure 2-31. Data Pair and Spare Pair are the POE connections on the data transformers used to source the power over Ethernet. $V_{AUX}$ is a local backup power source if desired. Isolated Output is the isolated raw output from the POE sub-circuit. + +![Figure 2-31: POE Reference Design Diagram. This schematic diagram illustrates the power-over-Ethernet (POE) reference design. It features a central 'Power over Ethernet Controller' block with pins for VPORT, HSGATE, HSSRC, AUX, PWRGD, and GND. The controller is connected to a 'Power over Ethernet Controller' block. The input side shows a 'DATA PAIR' and 'U8 PAIR' connected to transformers. The 'DATA PAIR' transformer has 'ma' and 'ppi' terminals. The 'U8 PAIR' transformer has 'ma' and 'ppi' terminals. A local backup power source 'V_AUX (9V to 60Vi)' is connected to the 'AUX' pin of the controller. The controller's output is connected to an 'Isolated Power Supply' block, which has 'V_IN' and 'Run' pins. The 'Isolated Power Supply' block provides an 'Isolated Output'. Various passive components are shown, including capacitors (C_PD, C_PORT, 47nF), resistors (3.3k), and a diode. The output of the controller is connected to the 'VPORT' pin of the 'Isolated Power Supply' block. The 'HSGATE' pin of the controller is connected to the 'VPORT' pin of the 'Isolated Power Supply' block. The 'HSSRC' pin of the controller is connected to the 'VPORT' pin of the 'Isolated Power Supply' block. The 'AUX' pin of the controller is connected to the 'AUX' pin of the 'Isolated Power Supply' block. The 'PWRGD' pin of the controller is connected to the 'PWRGD' pin of the 'Isolated Power Supply' block. The 'GND' pin of the controller is connected to the 'GND' pin of the 'Isolated Power Supply' block.](1a3aa71b2dda4f2097f306bf1d1b69c5_img.jpg) + +Figure 2-31: POE Reference Design Diagram. This schematic diagram illustrates the power-over-Ethernet (POE) reference design. It features a central 'Power over Ethernet Controller' block with pins for VPORT, HSGATE, HSSRC, AUX, PWRGD, and GND. The controller is connected to a 'Power over Ethernet Controller' block. The input side shows a 'DATA PAIR' and 'U8 PAIR' connected to transformers. The 'DATA PAIR' transformer has 'ma' and 'ppi' terminals. The 'U8 PAIR' transformer has 'ma' and 'ppi' terminals. A local backup power source 'V\_AUX (9V to 60Vi)' is connected to the 'AUX' pin of the controller. The controller's output is connected to an 'Isolated Power Supply' block, which has 'V\_IN' and 'Run' pins. The 'Isolated Power Supply' block provides an 'Isolated Output'. Various passive components are shown, including capacitors (C\_PD, C\_PORT, 47nF), resistors (3.3k), and a diode. The output of the controller is connected to the 'VPORT' pin of the 'Isolated Power Supply' block. The 'HSGATE' pin of the controller is connected to the 'VPORT' pin of the 'Isolated Power Supply' block. The 'HSSRC' pin of the controller is connected to the 'VPORT' pin of the 'Isolated Power Supply' block. The 'AUX' pin of the controller is connected to the 'AUX' pin of the 'Isolated Power Supply' block. The 'PWRGD' pin of the controller is connected to the 'PWRGD' pin of the 'Isolated Power Supply' block. The 'GND' pin of the controller is connected to the 'GND' pin of the 'Isolated Power Supply' block. + +Figure 2-31: POE Reference Design Diagram + +### 2.3.7 Thermal + +O-RU<sub>8</sub> will use passive cooling. + +#### 2.3.7.1 Environmental and Regulations + +The O-RU<sub>8</sub> hardware system is RoHS Compliant. The power supply unit is EMC FCC/CISPR Class B compliant. Table 2-29 lists the environmental related features and parameters. + +Table 2-29: Environmental Features + +| Item Name | Description | +|---------------------------------|----------------------------| +| Operating Temperature | -5°C to +55°C | +| Non-operating Temperature | -40°C to 70°C | +| Operating Relative Humidity | 8% to 90% (non-condensing) | +| Non-operating Relative Humidity | 5% to 95% (non-condensing) | + +## 2.4 FHM<sub>8</sub> Hardware Reference Design + +The FHM<sub>8</sub> is used to bridge the connection between O-DU<sub>8</sub> and O-RU<sub>8</sub>. It needs to power the O-RU<sub>8</sub> and reduces the front haul bandwidth. + +## 2.5 FHM<sub>8</sub> High-Level Functional Block Diagram + +Figure 2-32 shows the FHM<sub>8</sub> block diagram for this reference design. Following sections below describe the functionality, interface and performance for each respective block of the Digital Processing Unit. As device integration is an ongoing activity, chip boundaries may be fluid and some functionality may move from one block to another or entire functionalities may be absorbed into other blocks. The sections below describe the functional blocks independent of which physical device they may reside in. + +![Figure 2-32: FHM8 General Block Diagram. The diagram shows a central 'FPGA+ARM' block. On the left, a 'Power' block receives '220V AC' and outputs '48V' to 'Power interface1' and 'Power interface8'. Above the 'FPGA+ARM' block, there are 'RJ45' and 'RS232' interfaces. To the right, there are '25G SFP+' ports labeled 'Uplink' and 'Cascade', connected via 'Serdes' to '10G SFP+.1' and '10G SFP+.8'. The 'FPGA+ARM' block is also connected to 'DDR', 'Flash', 'CLK', and 'FAN'.](b0fc22b0386a60eb73f8892ef051dd19_img.jpg) + +``` + +graph TD + AC[220V AC] --> Power[Power] + Power --> 48V[48V] + 48V --> PI1[Power interface1] + 48V --> PI8[Power interface8] + + RJ45[RJ45] --> RS232[RS232] + RS232 --> FPGA[FPGA+ARM] + + FPGA <--> DDR[DDR] + FPGA <--> Flash[Flash] + FPGA --> CLK[CLK] + FPGA --> FAN[FAN] + + FPGA -- Serdes --> SFP1[10G SFP+.1] + FPGA -- Serdes --> SFP8[10G SFP+.8] + + SFP1 --- SFP8 + + SFP1 <--> Uplink[25G SFP+ Uplink] + SFP8 <--> Cascade[25G SFP+ Cascade] + +``` + +Figure 2-32: FHM8 General Block Diagram. The diagram shows a central 'FPGA+ARM' block. On the left, a 'Power' block receives '220V AC' and outputs '48V' to 'Power interface1' and 'Power interface8'. Above the 'FPGA+ARM' block, there are 'RJ45' and 'RS232' interfaces. To the right, there are '25G SFP+' ports labeled 'Uplink' and 'Cascade', connected via 'Serdes' to '10G SFP+.1' and '10G SFP+.8'. The 'FPGA+ARM' block is also connected to 'DDR', 'Flash', 'CLK', and 'FAN'. + +Figure 2-32: FHM<sub>8</sub> General Block Diagram + +## 2.6 FHM<sub>8</sub> Hardware Components + +### 2.6.1 Digital Processing Unit + +The FHM<sub>8</sub> need a lot of high speed interface. And for the shared cell application, the uplink need combining function. + +#### i. FPGA Solution Design 1 + +In this section, the requirement and reference design based on FPGA are described. + +#### a. FPGA Requirement + +The requirements are as follows: + +- Interface requirement + +**Table 2-30: Interface requirements of the FPGA** + +| Item Name | Description | +|-------------|---------------------------------------------| +| SerDes lane | At least 8 lanes of bi-direction10Gb SerDes | +| | At least 2 lanes of bi-direction25Gb SerDes | + +#### b. FPGA Design + +This unit handles multiple high speed interfaces and the digital signal processing. The main chipset is based on FPGA with ARM multi-core processor while FPGA is responsible for high speed data processing and ARM cores are mainly for configuration and management. + +The FPGA function is shown below: + +For the uplink processing, the CPRI interface module is used to receiver CPRI link form O-RU<sub>8</sub> and generate the reference frequency and time slot for time and frequency synchronization. Then the CPRI de-frame module get the uplink IQ bit stream of the time domain the carrier from O-RU<sub>8</sub>. If the uplink IQ stream is compressed, then it needs the de-compression module to translate them into original bit width. + +After that all the O-RU<sub>8</sub> uplink IQ streams are combined together and the precondition for the combine function is that each stream from different O-RU<sub>8</sub> are aligned in time domain. + +If the FHM<sub>8</sub> can support two separate cells then the two cell uplink signal should be aggregated or interleaved together. Then capture the IQ streams in the CPRI frame and transmitted by CPRI interface to the O-DU<sub>8</sub>. + +For the downlink processing, the procedure is much the same with uplink but with an inverse sequence. The difference is that the downlink signal is duplicated with 8 copies and sends to different O-RU<sub>8</sub>. + +There is also a CPRI OAM module; actually this module will work with the processor (Arm) to accommodate the OAM of different O-RU<sub>8</sub> and the FHM<sub>8</sub> itself. + +![Figure 2-33: FHM8 Digital Processing Block Diagram. The diagram shows two main data paths. The top path is a receive chain: CPRI interface -> CPRI frame -> Compression -> Other cell aggregation -> I/Q combination. The bottom path is a transmit chain: CPRI interface -> CPRI de-frame -> Other cell aggregation -> I/Q mux. There are three parallel processing units for both paths. The top path also includes Buffer, De-compress, and CPRI de-frame blocks. The bottom path also includes Buffer and CPRI frame blocks. An 'Other cell' input is shown entering the 'Other cell aggregation' block. An 'Ethernet OAM' block is shown connected to the 'Other cell aggregation' block.](44c65605d70e12adfc18d1f1f79bead3_img.jpg) + +Figure 2-33: FHM8 Digital Processing Block Diagram. The diagram shows two main data paths. The top path is a receive chain: CPRI interface -> CPRI frame -> Compression -> Other cell aggregation -> I/Q combination. The bottom path is a transmit chain: CPRI interface -> CPRI de-frame -> Other cell aggregation -> I/Q mux. There are three parallel processing units for both paths. The top path also includes Buffer, De-compress, and CPRI de-frame blocks. The bottom path also includes Buffer and CPRI frame blocks. An 'Other cell' input is shown entering the 'Other cell aggregation' block. An 'Ethernet OAM' block is shown connected to the 'Other cell aggregation' block. + +Figure 2-33: FHM8 Digital Processing Block Diagram + +The resource needed for the FPGA is listed below: + +Table 2-31: FPGA Resource usage for FHM8 + +| Device | FF | LUT | URAM | BRAM | DSP | +|--------------------|-------|-------|------|------|-----| +| IQ MUX | 1000 | 1000 | 0 | 0 | 0 | +| Cascade | 2000 | 2000 | 0 | 0 | 0 | +| IQ combine | 2000 | 2000 | 0 | 32 | 0 | +| CPRI deframe*9 | 45000 | 45000 | 0 | 0 | 0 | +| CPRI frame*9 | 45000 | 45000 | 0 | 0 | 0 | +| Fronthaul(CPRI)x10 | 47500 | 31000 | 0 | 10 | 0 | +| compress*1 | 3000 | 3000 | 0 | 24 | 32 | +| de_compress*8 | 24000 | 24000 | 0 | 192 | 208 | +| ethernet_cm | 3000 | 3000 | 0 | 15 | 0 | +| Other | 20000 | 15000 | 0 | 200 | 0 | + +### 2.6.2 Synchronization and Timing + +In this section we describe the internal and external timing and synchronization that are managed by this entity. + +#### a. Hardware Requirements + +- CLK requirement + +The FHM<sub>8</sub> may support some kinds of synchronization method: + +- 1) Support GPS/GLONASS/GALILEO/BEIDOU + +So the PLL must support 1pps or CPRI CDR as the reference frequency. + +**Table 2-32: Requirements of the PLL device** + +| Device | Description | +|---------------------|-------------| +| 1PPS | Supported | +| Synchronizer number | at least 1 | +| Output channel | At least 5 | +| VCO integrated | Supported | + +#### b. Hardware Design + +This unit is to recover clock from external source and generate the synchronized clock to other devices. Upon scenarios, there will be external sync source via CPRI. + +![Figure 2-34: CLK reference design for FHM8. The diagram shows a central block labeled 'CLK'. An input arrow from the left is labeled 'Reference clock from FPGA' and '122.88MHz'. Five output arrows point to the right, labeled with frequencies and destinations: '122.88MHz' to 'To FPGA 25G Serdes', '122.88MHz' to 'To FPGA 10 Serdes0', '122.88MHz' to 'To FPGA 10G Serdes1', '125MHz' to 'For FPGA sys', and '250MHz' to 'For DDR function'.](5bfe35febb939a72e91d4570f34b807b_img.jpg) + +Figure 2-34: CLK reference design for FHM8. The diagram shows a central block labeled 'CLK'. An input arrow from the left is labeled 'Reference clock from FPGA' and '122.88MHz'. Five output arrows point to the right, labeled with frequencies and destinations: '122.88MHz' to 'To FPGA 25G Serdes', '122.88MHz' to 'To FPGA 10 Serdes0', '122.88MHz' to 'To FPGA 10G Serdes1', '125MHz' to 'For FPGA sys', and '250MHz' to 'For DDR function'. + +**Figure 2-34: CLK reference design for FHM<sub>8</sub>** + +For general FPGA device, each bank may have four SerDes channels. It is better to have separated CLK signal to each bank. Three CLK signals of 122.88MHz are needed for the FHM<sub>8</sub>. One CLK signal of 125MHz is used for FPGA system, while one CLK signal of 250MHz is used for DDR device function. The input of the CLK module comes from FPGA CDR function which can get reference CLK from the CPRI line rate. Usually, one PLL device integrated with VCO is needed. + +### 2.6.3 External Interface Ports + +List and provide description of all external interfaces. + +#### a. Hardware Requirements + +The following table shows the external ports or slots provided by FHM<sub>8</sub>. + +**Table 2-33: External Port List** + +| Port Name | Feature Description | +|---------------------|------------------------------------------| +| Fronthaul interface | Eight 10Gbps SFP+ transceiver interfaces | +| | Two 25Gbps SFP+ transceiver interfaces | +| Debug interface | RJ45 for debug usage | +| Power interface | PLUG AC FEMALE for power cable | + +#### b. Hardware Design + +- SFP+ case and connector + +The SFP+ case and connector are standardized component on the market; following figure describes the form factor of one SFP case which is integrated with connector. + +![A 3D perspective drawing of an SFP+ (Small Form-factor Pluggable Plus) module. It is a rectangular component with a metal housing. On the front face, there are several circular ports (likely for optical or electrical connections) and a small latch mechanism. The side of the module shows a series of gold-plated pins (Gullwing connectors) used for interfacing with a host device.](dee435732129f137d4ba86a903009297_img.jpg) + +A 3D perspective drawing of an SFP+ (Small Form-factor Pluggable Plus) module. It is a rectangular component with a metal housing. On the front face, there are several circular ports (likely for optical or electrical connections) and a small latch mechanism. The side of the module shows a series of gold-plated pins (Gullwing connectors) used for interfacing with a host device. + +**Figure 2-35: SFP+ case and connector** + +- RJ45 Ethernet interface + +The RJ45 Ethernet interface is standardized component on the market; following figure describes the form factor of one RJ45 interface. + +![Isometric drawing of an RJ45 Ethernet interface connector.](08db15ca43cfcdd0dc32c059591d8fba_img.jpg) + +An isometric line drawing of an RJ45 Ethernet interface connector. It shows a rectangular plastic housing with a latch on the side. The front face features a port for an RJ45 plug and a series of eight pins on the top edge. A small tab is visible on the side of the housing. + +Isometric drawing of an RJ45 Ethernet interface connector. + +**Figure 2-36: RJ45 interface** + +- Power interface + +The 220V AC power connector is standardized component on the market; following figure describes the form factor of one 220V AC power connector. + +![Technical drawing of a 220V AC power connector showing front and side views with dimensions.](8b933c4cfbd2947f5b0a60800f4abd19_img.jpg) + +A technical drawing of a 220V AC power connector. It includes a front view on the left and a side view on the right. The front view shows a rectangular connector with a central pin and two side pins. Dimensions are indicated: a total width of 17, a central pin diameter of 4, and a distance of 14 from the center to the side pins. The side view shows the profile of the connector, including the pin and the housing. + +Technical drawing of a 220V AC power connector showing front and side views with dimensions. + +**Figure 2-37: AC power interface** + +### 2.6.4 Mechanical + +The 1U rack mount chassis can contains the layout of the power unit and processing unit. The shell of FHM<sub>8</sub> is showing in the following figure. The power consumption of FHM<sub>8</sub> is huge, so it may need a fan to accelerate the heat dissipation. + +![Figure 2-38: Shell Mechanical Diagram. A 3D perspective drawing of a 1U rack mount chassis. The chassis is rectangular with a front panel and a rear panel. A fan is mounted on the top surface. Dimensions are indicated: 440mm for the front width, 482mm for the rear width, 250mm for the depth, and 44mm for the height.](cddd4ef3dfe26eb59c7ca31dfc4644d9_img.jpg) + +Figure 2-38: Shell Mechanical Diagram. A 3D perspective drawing of a 1U rack mount chassis. The chassis is rectangular with a front panel and a rear panel. A fan is mounted on the top surface. Dimensions are indicated: 440mm for the front width, 482mm for the rear width, 250mm for the depth, and 44mm for the height. + +**Figure 2-38: Shell Mechanical Diagram** + +### 2.6.5 Power + +At minimum, fully describe the power consumptions for this white box. Include all AC/DC input or outputs and their ratings. Not mandatory but if you like you can add summary of all component's power requirement and overall white box. + +#### a. Hardware Requirements + +- Power requirement: The power solution is divided into two parts. + 1. Input power module: This power module must support AC to DC conversion. Usually it converts 220V AC to 48V DC. + 2. Output power module: It will supply power to the O-RU<sub>8</sub> connected to the FHM<sub>8</sub> and also the device on the FHM<sub>8</sub> itself. + +**Table 2-34: Requirements of the power unit** + +| Item | Description | +|----------------|---------------| +| Input voltage | AC:100V~264V | +| Output voltage | DC: 48V | +| Output power | At least 600W | + +###### 1       ***b. Hardware Design*** + +2       Describe hardware reference design for this power unit. + +3       This unit has two main functions which are internal power supply and external/remote power supply. The input +4       power is normally AC (100V to 250V) but DC input could be optional. For remote power supply, it will support +5       -48V DC via either standalone cable or cat-6A cable. + +6       Usually a separated AC-DC power supply is used for the 220V to 48V conversion. It is very common power +7       supply on the market. + +8       It should have fan to cool itself and handle for easy plug in and out. + +9       Then the output power is divided into two portions. One for O-RU<sub>8</sub> power supply, the other is for the device on +10       the FHM<sub>8</sub> board. + +11       For the on-board power solution, 48V to 12V converter is needed as standard 1/8 brick module. Then the power +12       voltage is further changer to lower level such as 5V, 3.3V, 1.1V, 1.0V and so on by DC/DC or LDO devices. + +###### 13       **2.6.6 Thermal** + +14       Active cooling. + +###### 15       **2.6.7 Environmental and Regulations** + +16       The FHM<sub>8</sub> will fulfil the requirement in 4.6.3 of [6]. + +# Annex 1 Parts Reference List + +According to WG7 scope and charter, component selection for example implementation of white box hardware is allowed for WG7 but would not be mandatory in any Specification. + +Recommended O-DU<sub>8</sub> parts reference is given in table below: + +| No. | Part Number | Descriptions | +|-----|--------------------------------------|---------------------------------------------| +| 1 | Intel® Xeon® Processor D-2183IT | Intel® Xeon® Skylake D D-2100 SoC processor | +| 2 | Intel® I350 | Intel® 1GbE x4 Ethernet controller | +| 3 | Intel® X557-AT2 | Intel® 10GbE x2 Ethernet controller | +| 4 | Intel® I210 | Intel® 1GbE Ethernet controller | +| 5 | ASPEED® AST-2500 | ASPEED® BMC controller | +| 6 | UniC® SCQ08GU03H1F1C-26V | UniC® DDR4 8GB | +| 7 | Powerleader® MTFDDAK480TDC-1AT1ZABYY | Powerleader® SSD 480GB | +| 8 | Accelink® RTXM228-551 | Accelink® 10Gbps Optical module | + +# Annex 2 CPRI specification reference design + +## A2.1 Scope + +The present document specifies the CPRI Control Plane, User Plane and Synchronization Plane management plane protocols used over the fronthaul interface in 5G-NR. + +## A2.2 Reference + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. + +- For a specific reference, subsequent revisions do not apply. + +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 15. + +[1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications” + +[2] Interface Specification: “CPRI Specification Common Public Radio Interface (CPRI)”, V7.0, October 2015. + +## A2.3 Definitions and Abbreviations + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [1]. + +| Abbreviations | Full name | +|---------------|-------------------------------| +| C&M | Control and Management | +| CPRI | Common Public Radio Interface | +| LOF | Lost of Frame | +| LOS | Lost of Signal | +| LSB | Least Significant Bit | + +| | | +|-------------------|-------------------------| +| M-Plane | Management Plane | +| MSB | Most Significant Bit | +| O-DU <sub>8</sub> | O-RAN Distributed Unit | +| FHM <sub>8</sub> | Fronthaul Multiplexer | +| O-RU <sub>8</sub> | O-RAN Radio Unit | +| RAI | Remote Alarm Indication | +| S-Plane | Synchronization Plane | +| SAP | Service Access Point | +| SDI | SAP Defect Indication | +| U-Plane | User Plane | + +## A2.4 High Level Description + +### A2.4.1 System Architecture + +This specification defines the protocol of the fronthaul interface for 5G indoor picocell system. + +5G digital indoor distribution system is composed of O-DU<sub>8</sub>, FHM<sub>8</sub> and O-RU<sub>8</sub>, providing wireless network access function for users. Optical fiber is used to carry signals between O-DU<sub>8</sub> and FHM<sub>8</sub>, and photoelectric composite cable or network cable can be used to carry signals between FHM<sub>8</sub> and O-RU<sub>8</sub>. Due to upgrade evolution, cost and other considerations, optoelectronic composite cable connection is preferred between FHM<sub>8</sub> and O-RU<sub>8</sub>. + +Each functional entity in the system architecture is defined as follows: + +O-RAN Distributed Unit (O-DU<sub>8</sub>): A O-DU<sub>8</sub> logical node that includes the eNB/gNB functional subset with Split-8x listed in Section 4.2. Mainly realize the modulation and demodulation of baseband signals. + +O-RAN Radio Unit (O-RU<sub>8</sub>): A O-RU<sub>8</sub> logical node that includes the eNB/gNB functional subset with Split-8x listed in Section 4.2. Realize the transmission and reception of radio frequency signals. Receive the downlink signal from the FHM<sub>8</sub>, modulate it into a radio frequency signal and then transmit it through the antenna; receive the radio frequency signal from the antenna, perform corresponding signal processing, and send it to the O-DU<sub>8</sub> through the FHM<sub>8</sub> for processing. + +O-RAN FHM<sub>8</sub>: Work with O-DU<sub>8</sub> and O-RU<sub>8</sub>. Receive downlink data sent by O-DU<sub>8</sub> and transmit to O-RU<sub>8</sub> after shunt processing; the uplink data sent by O-RU<sub>8</sub> is sent to O-DU<sub>8</sub> after a certain junction processing to realize communication with O-DU<sub>8</sub>. + +This specification is based on option 8 CPRI fronthaul interface, which can be applied to the interface between O-DU<sub>8</sub> and FHM<sub>8</sub>, as well as the interface between FHM<sub>8</sub> and O-RU<sub>8</sub>. The system architecture is shown in following figure. + +![Figure Annex2-1: system architecture diagram showing O-DU8, FHM8, U8, and O-RU8 components connected via CPRI interfaces using optical fiber and photoelectric composite cables.](2992abc4ff8a63bbc59cabb3acbea7ce_img.jpg) + +The diagram illustrates the system architecture for Option 8 CPRI fronthaul. It shows an O-DU<sub>8</sub> block on the left, connected via CPRI (red lines) to two FHM<sub>8</sub> blocks in the center. The top FHM<sub>8</sub> block is connected to multiple O-RU<sub>8</sub> blocks on the right. The bottom FHM<sub>8</sub> block is connected to a U<sub>8</sub> block, which is then connected to multiple O-RU<sub>8</sub> blocks. A legend at the bottom indicates that red lines represent optical fiber and black lines represent photoelectric composite cable or network cable. Vertical dashed lines separate the O-DU<sub>8</sub>, FHM<sub>8</sub>, and O-RU<sub>8</sub> sections. + +Figure Annex2-1: system architecture diagram showing O-DU8, FHM8, U8, and O-RU8 components connected via CPRI interfaces using optical fiber and photoelectric composite cables. + +Figure Annex2-1: system architecture + +### A2.4.2 Functional Split + +There are many ways to split the function between O-DU<sub>8</sub> and O-RU<sub>8</sub>. This specification adopts the Option 8 of O-RAN functional split option. + +1 Following figure shows the functional split of the Option 8. In order to show the split point more intuitively, the +2 FHM<sub>8</sub> and O-RU<sub>8</sub> are regarded as a whole, which is represented by O-RU<sub>8</sub> in the figure. + +![Functional split diagram for Option 8 showing O-D and O-R blocks.](409c525aa7b6cb3c435b6e49d0c09006_img.jpg) + +The diagram illustrates the functional split for Option 8. It is divided into two main sections: O-D (Open Distributed Unit) and O-R (Open RAN). The O-D section contains the following functional blocks from top to bottom: Interweave, Modulation, Layer, Precoding (indicated by a dashed border), Resource mapping, Beamforming (indicated by a dashed border), Add/Remove CP, and Compression / Decompression. The O-R section contains the following functional blocks from top to bottom: Decompression / Compression, Filter, and DA/AD conversion. A horizontal line labeled 'Option 8' separates the O-D and O-R sections. + +Functional split diagram for Option 8 showing O-D and O-R blocks. + +Figure Annex2- 2: option 8 functional split + +### A2.4.3 Data Flow + +6 In order to exchange information between O-DU<sub>8</sub> and O-RU<sub>8</sub>, the data flows required by the fronthaul interface +7 based on the split option 8 can be categorized as follows. Moreover, Table 1 shows the content mapping of the data +8 flow. ID in the table below is just for ease of description. + +- 9 • User Plane + - 10 - Data flow 1a: IQ data flow in DL time domain; + - 11 - Data flow 1b: IQ data flow in UL time domain. +- 12 • Control Plane + - 13 - Data flow 2a: Real-time control command issuance; + - 14 - Data flow 2b: Real-time information reporting from lower layers. +- 15 • Synchronization Plane + - 16 - Data flow S: Synchronization information. +- 17 • Management Plane + +- Data flow M: Management information. + +![Figure Annex2- 3: Fronthaul data flow diagram showing data flow between O-D and O-RUg blocks.](49223ffeaef46f815b5a4b0c47d7fd0b_img.jpg) + +The diagram illustrates the fronthaul data flow between an O-D (Open Distributed Unit) and an O-RU<sub>g</sub> (Open Radio Unit). The flows are categorized into four main types: + +- User Plane:** + - 1a: IQ data flow in DL time domain (from O-D to O-RU<sub>g</sub>) + - 1b: IQ data flow in UL time domain (from O-RU<sub>g</sub> to O-D) +- Control Plane:** + - 2a: Real-time control command (from O-D to O-RU<sub>g</sub>) + - 2b: Real-time information reporting from lower (from O-RU<sub>g</sub> to O-D) +- Synchronization Plane:** + - S: Synchronization information (from O-D to O-RU<sub>g</sub>) +- Management Plane:** + - M: Management (from O-RU<sub>g</sub> to O-D) + +Figure Annex2- 3: Fronthaul data flow diagram showing data flow between O-D and O-RUg blocks. + +**Figure Annex2- 3: Fronthaul data flow** + +**Table Annex2- 1 Data flow information mapping** + +| Plane | ID | Name | Content | +|-----------------------|----|---------------------------------|-----------------------------------------------------------------| +| User Plane | 1a | IQ data flow in DL time domain | IQ data flow in DL time domain | +| | 1b | IQ data flow in UL time domain | IQ data flow in UL time domain | +| Control Plane | 2a | Real-time control information | Ethernet speed configuration, RESET command, etc | +| | 2b | Real-time information reporting | Power failure alarm, LOS, LOF, etc | +| Synchronization Plane | S | Synchronization information | Super frame start indicator, HFN,BFN | +| Management Plane | M | Management information | Parameter configuration, file management, fault management, etc | + +## A2.5Interface Protocol Overview + +Based on the CPRI protocol, refer to section 4.1 of the CPRI v7.0 specification, which is divided into user plane, control plane, synchronization plane and management plane. + +The user plane is carried by IQ data. The control plane transmits real-time control information, which is mainly carried by the vendor's specific control words and the L1 inband protocol. The synchronization plane ensures the stability of clock recovery through the assistance of line coding, and at the same time transmits time information through the control word. The management plane is carried by Ethernet. + +![Interface protocol architecture diagram showing Layer 2 and Layer 1 components.](93f3be3f8a2e201d74b20d930ca972d2_img.jpg) + +The diagram illustrates the interface protocol architecture across two layers. Layer 2 is divided into four main sections: User Plane (carrying IQ Data), Control & Management Plane (carrying Vendor Specific and Ethernet data), and SYNC (carrying L1 Inband Protocol). These sections are multiplexed in Layer 1 using Time Division Multiplexing (TDM). The Layer 1 output is then transmitted via either Electrical Transmission or Optical Transmission. + +| | | | | +|---------|-------------------------|-----------------------------|----------------------| +| | User Plane | Control & Management Plane | SYNC | +| Layer 2 | IQ Data | Vendor Specific<br>Ethernet | L1 Inband Protocol | +| | Time Division Multiplex | | | +| Layer 1 | Electrical Transmission | | Optical Transmission | + +Interface protocol architecture diagram showing Layer 2 and Layer 1 components. + +Figure Annex2- 4 : Interface protocol architecture + +## A2.6 Functional Requirements + +### A2.6.1 Supported Scenarios + +This specification supports CPRI interface to carry 5G NR single-mode transmission. The specific scenarios supported include but are not limited to: + +1. The CPRI interface carries a single or two 5G NR cells with a 50MHz bandwidth of 2T2R. +2. The CPRI interface carries a single or two 5G NR cells with a bandwidth of 50MHz and 4T4R. +3. The CPRI interface carries a single or two 5G NR cells with a bandwidth of 100MHz (or 80MHz) and 2T2R. +4. The CPRI interface carries a single or two 5G NR cells with a bandwidth of 100MHz (or 80MHz) and 4T4R. +5. The CPRI interface carries four 5G NR cells with a bandwidth of 100MHz (or 80MHz) and 2T2R. + +This specification also supports CPRI interface to carry 5G NR and 4G LTE dual-mode transmission. The specific scenarios supported include but are not limited to: + +1. The CPRI interface carries a single 5G NR cell with 100MHz (or 80MHz) bandwidth and 4T4R and a + +single 4G LTE cell with 20MHz bandwidth and 2T2R. + +2. The CPRI interface carries a single 5G NR cell with 100MHz (or 80MHz) bandwidth and 4T4R and two 4G LTE cell with 20MHz bandwidth and 2T2R. +3. The CPRI interface carries two 5G NR cell with 100MHz (or 80MHz) bandwidth and 4T4R and two 4G LTE cell with 20MHz bandwidth and 2T2R. + +### A2.6.2 Line Bit Rate + +This specification only selects part of the line bit rates and line coding method from the CPRI specification. This specification focuses on the scenario with the maximum capacity that a line rate can carry, that is, only the upper limit is specified. + +1. CPRI line bit rate option 10: 24330.24Mbps, 64B/66B line coding (48 x 491.52 x 66/64 Mbit/s). +Optical fiber is used for transmission, and the optical interface rate used should not be lower than 25G. + +This rate is applicable to the following scenarios and other scenarios with lower rate requirements: + +- 1) Upper limit of dual-mode: The CPRI interface carries two 5G NR cell with 100MHz bandwidth and 4T4R and two 4G LTE cell with 20MHz bandwidth and 2T2R. +- 2) Upper limit of single-mode: The CPRI interface carries two 5G NR cell with 100MHz bandwidth and 4T4R. + +2. CPRI line bit rate option 9: 12165.12Mbps, 64B/66B line coding (24 x 491.52 x 66/64 Mbit/s). +Optical fiber is used for transmission, and the optical interface rate used should not be lower than 12.5G. + +This rate is applicable to the following scenarios and other scenarios with lower rate requirements: + +- 1) Upper limit of dual-mode: The CPRI interface carries a single 5G NR cell with 100MHz bandwidth and 4T4R and two 4G LTE cell with 20MHz bandwidth and 2T2R. +- 2) Upper limit of single-mode: The CPRI interface carries a single 5G NR cell with 100MHz bandwidth and 4T4R. + +3. CPRI line bit rate option 8: 10137.6Mbps, 64B/66B line coding (20 x 491.52 x 66/64 Mbit/s). + +If optical fiber and photoelectric composite cable are used for transmission, the optical interface rate should not be lower than 10G. If a network cable is used for transmission, the electrical interface should support a rate of 10GE or above. (This specification temporarily does not make mandatory requirements for electrical interface transmission and its transmission format.) + +This rate is applicable to the following scenarios and other scenarios with lower rate requirements: + +- 1) Upper limit of dual-mode: The CPRI interface carries a single 5G NR cell with 100MHz bandwidth and 4T4R and a single 4G LTE cell with 20MHz bandwidth and 2T2R. +- 2) Upper limit of single-mode: The CPRI interface carries a single 5G NR cell with 100MHz bandwidth and + +4T4R. + +### A2.6.3 Network Form + +This specification supports two topologies: star topology and chain topology. + +Star topology means that one O-DU<sub>8</sub> can connect to multiple FHM<sub>8</sub>s, and one FHM<sub>8</sub> can connect to multiple O-RU<sub>8</sub>s. + +Chain topology means that FHM<sub>8</sub> can be cascaded. + +### A2.6.4 Frame Synchronization + +Interface synchronization includes providing accurate frame information, and the FHM<sub>8</sub> also needs to provide frame information to subordinate FHM<sub>8</sub> and O-RU<sub>8</sub>. The frame timing information is calibrated by O-DU<sub>8</sub> at regular intervals to ensure the normal operation of the entire system. + +### A2.6.5 IQ Bit Width of User Plane + +User plane data is transmitted in the form of IQ data with a width of 16 bits. However, due to the actual bandwidth requirements, IQ data compression technology is required. The compression algorithm and compression ratio are shown in Chapter 8.2. + +### A2.6.6 Link Maintenance + +Four link-related alarms are defined in the CPRI Specification: LOS, LOF, RAI and SDI. For details, please refer to the CPRI v7.0 specification, section 4.2.10. + +### A2.6.7 Hot Plug Function + +Support hot plug function, that is, during O-DU<sub>8</sub> operation, the CPRI interface can still resume normal communication after the FHM<sub>8</sub> is unplugged and plugged. During the operation of the FHM<sub>8</sub>, after the O-RU<sub>8</sub> connected to it is unplugged and plugged, the CPRI interface between of them can still resume normal communication. + +### A2.6.8 Working Mode + +In this specification, the CPRI interfaces can be applied to interfaces in the following connection modes: + +1. O-RU<sub>8</sub> connected to FHM<sub>8</sub> +2. FHM<sub>8</sub> connected to O-DU<sub>8</sub> +3. FHM<sub>8</sub> cascaded to FHM<sub>8</sub> + +## A2.7 Performance Requirement + +### A2.7.1 Synchronization + +Refer to CPRI V7.0 specification, section 4.2.8. + +### A2.7.2 Link Delay Accuracy + +Refer to CPRI V7.0 specification, section 4.2.9. + +### A2.7.3 Bit Error + +Refer to CPRI V7.0 specification, section 4.2.6. + +### A2.7.4 Layer 1 Start-up Timer + +Refer to CPRI V7.0 specification, section 4.5.2. + +## A2.8 Interface physical layer + +### A2.8.1 Frame structure + +The frame structure refers to cpriv 7.0 specification, section 4.2.7. As shown in the figure below. + +![Figure Annex2- 5: CPRI frame structure. The diagram shows a frame structure with 16 words (W=0 to 15). Each word is 1 chip = 1/3.84MHz. The frame is divided into three sections: Y=0 (B=0 to B=Tcw/8-1), Y=Tcw/8 (B=Tcw to B=Tcw+1), and Y=(T/8-1) (B=(T-8) to B=(T-1)). The frame contains a 'Data block' and an 'IQ' section. The total length is 15 * T bits. A timeline on the right shows the sequence of bytes over time.](6b941cd502168634545a10be7aaf8fe8_img.jpg) + +Figure Annex2- 5: CPRI frame structure. The diagram shows a frame structure with 16 words (W=0 to 15). Each word is 1 chip = 1/3.84MHz. The frame is divided into three sections: Y=0 (B=0 to B=Tcw/8-1), Y=Tcw/8 (B=Tcw to B=Tcw+1), and Y=(T/8-1) (B=(T-8) to B=(T-1)). The frame contains a 'Data block' and an 'IQ' section. The total length is 15 \* T bits. A timeline on the right shows the sequence of bytes over time. + +Figure Annex2- 5 : CPRI frame structure + +The length of a basic frame is $1 \text{ TC} = 1 / \text{FC} = 1 / 3.84 \text{ MHz} = 260.416667\text{ns}$ . A basic frame contains 16 words, and the corresponding index is $w = 0 \dots 15$ . The length $t$ of each word is related to the corresponding line rate. Each bit in each word has an index $B$ , $B = 0$ is LSB, $B = T-1$ is MSB. Every byte in a word is indexed by $Y$ , $B = 0$ is the LSB of $y = 0$ , $B = 7$ is the MSB of $y = 0$ , $B = 8$ is the LSB of $y = 1$ , and so on. + +When the line rate is 10137.6Mbps, the range of $Y$ is $0 \sim 19$ . When the line speed is 12165.12Mbps, the range of $Y$ is $0 \sim 23$ . When the line rate is 24330.24Mbps, the range of $Y$ is $0 \sim 47$ . + +Table Annex2- 2 Control Word Length + +| CPRI[M bit/s] | [bit] | Control word length[bit] | BYTES# Control word contains BYTES | +|---------------|---------|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------| +| 10137.6 | $T=160$ | $T_{cw}=128$ | #Z.X.0,#Z.X.1,#Z.X.2,#Z.X.3,<br>#Z.X.4,#Z.X.5,#Z.X.6,#Z.X.7,#Z.X.8,<br>#Z.X.9,#Z.X.10,#Z.X.11,#Z.X.12,<br>#Z.X.13,#Z.X.14,#Z.X.15 | +| 12165.12 | $T=192$ | | | +| 24330.24 | $T=384$ | | | + +According to CPRI protocol, the first $T_{cw}$ bits of the first word ( $w = 0$ ) in each basic frame are used as control words. If $T_{cw}$ is less than $t$ , the remaining $T - T_{cw}$ bits in the word $w = 0$ can be used to transmit real-time control information. + +### A2.8.2 IQ data compression + +In the specification, we stipulate that IQ data compression is implemented by block floating point compression algorithm, the specific algorithm is listed in the appendix A.1, after compression the bit width of IQ data is eight bits. + +The unit of IQ compression is called a compression block. The corresponding compression information bit width (shared exponent of compression block) is four bits in each compression block. + +In the specification, all samples of same antenna-carrier in a basic frame are treated as a compression block. + +Take an antenna-carrier of one NR cell of 100MHz bandwidth for example, compression block contains 32 samples of IQ data. If CPRI is carrying four antennas of an NR cell, there are four compression blocks in a basic frame. + +Take an antenna-carrier of one LTE cell of 20MHz bandwidth for example, compression block contains 8 samples of IQ data. If CPRI is carrying two antennas of an LTE cell, there are two compression blocks in a basic frame. + +### A2.8.3 IQ data mapping + +The unit of IQ data mapping is a basic frame, the total area starts from $W=1, Y=0$ , which contains compression information (shared exponent of compression block), IQ data and automatic gain control (AGC) in basic frame. + +In this specification there are default mapping modes of IQ data in different scenarios, which are listed in the appendix B. Start position and end position for IQ data and compression information data for each antenna are configured by M plane parameters. + +Samples of each antenna-carrier, compression information data of each compression block and arrangement of bits of AGC should follow the rules below. + +1. IQ data. In one sample of antenna-carrier, the bits of I data and the bits of Q data arrange alternately. As shown in the figure 6, I0 is LSB, I7 is MSB. + +2. Compression information data. The arrangement of bits in compression information data is shown in the figure 7. E0 is LSB, E3 is MSB in this. + +3. Automatic gain control (AGC) data. We use four bits of binary data to describe the link gain of each antenna, Zero corresponds to the maximal link gain. Every time the receiving link gain go down by 2db, the AGC value go up by 1. The field should be filled with default value 0 if it's not used. The internal bit sequence is the same as bit sequence of compression information, as shown in the figure 7, in which E0 is LSB,E3 is MSB. + +| | | +|----|------| +| I0 | B=0 | +| Q0 | B=1 | +| I1 | B=2 | +| Q1 | B=3 | +| I2 | B=4 | +| Q2 | B=5 | +| I3 | B=6 | +| Q3 | B=7 | +| I4 | B=8 | +| Q4 | B=9 | +| I5 | B=10 | +| Q5 | B=11 | +| I6 | B=12 | +| Q6 | B=13 | +| I7 | B=14 | +| Q7 | B=15 | + +Figure Annex2- 6: IQ arrangement in one sample + +| | | | +|--------------------------|----|-----| +| Compression | E0 | B=0 | +| information of the first | E1 | B=1 | +| compressed block | E2 | B=2 | +| Compression | E3 | B=3 | +| information for the | E0 | B=4 | +| second compression | E1 | B=5 | +| | E2 | B=6 | +| | E3 | B=7 | + +Figure Annex2- 7: Bit Arrangement in Compression Information + +### A2.8.4 Superframe Structure + +Refer to section 4.2.7.3 of CPRI v7.0 specification. + +### A2.8.5 Subchannel Definition + +Refer to section 4.2.7.4 of CPRI v7.0 specification + +### A2.8.6 Synchronize Data + +Refer to section 4.2.7.5 of CPRI v7.0 specification + +### A2.8.7 L1 inband protocol + +Refer to section 4.2.7.6 of CPRI v7.0 specification. + +### A2.8.8 C&M data channel + +This specification support C&M channel option 2 in CPRI protocol: Fast C&M channel that is based on Ethernet. The initial position of Ethernet channel is indicated by pointer p in the hyperframe. Pointer p is carried by #Z.194.0. Refer to section 4.2.7.6 of CPRI v7.0 specification about the definition of pointer p. + +In this specification, the value of pointer p is fixed value 20. + +### A2.8.9 Reserved control word + +In order to ensure the extensibility of future protocols, some control words need to be retained. Refer to section 4.2.7.8 of CPRI v7.0 specification. + +## A2.9 Data link layer + +The data link layer supports fast C&M channel. For the definition of fast C&M channel, please refer to section 4.2.7.7.2 of CPRI v 7.0 specification. + +The data rate of fast C&M channel (i.e. Ethernet rate) is shown in the table below. + +**Table Annex2- 3 Fast C&M Channel Rate** + +| CPRI<br>[Mbit/s] | [bit]<br>Control<br>word length | Control word contains BYTES# | [Mbit/s]<br>Ethernet<br>bit rate | +|------------------|---------------------------------|------------------------------|----------------------------------| +|------------------|---------------------------------|------------------------------|----------------------------------| + +| | | | | +|-----------------------------------|-----|-------------------------------------------------------------------------------------------------------------------------------|-------------------------------------| +| | | | [Mbit/s]<br>(#Z.194.0<br>=rr010100) | +| 10137.6,<br>12165.12,<br>24330.24 | 128 | #Z.X.0,#Z.X.1,#Z.X.2,#Z.X.3,#Z.X.4,#<br>Z.X.5,#Z.X.6,#Z.X.7,#Z.X.8,#Z.X.9,#Z.X.10<br>,#Z.X.11,#Z.X.12,#Z.X.13,#Z.X.14,#Z.X.15 | 337.92 | + +1 + +###### 2 A2.10 Appendix - Compression Methods + +###### 3 A2.10.1 Block floating point compression + +4 The following is the representation of block floating point compression. I sample data of each compression unit + 5 and Q sample data of each compression unit are converted to floating point data. A original compression unit + 6 contains several (for example 32) sample data that are represented by fixed bit width and signed integers. Each IQ + 7 sample is represented by sign and mantissa (for example 8 bits) and a shared exponent (see figure 8) in compressed + 8 compression unit. + +9 + +10 + +11 + +12 + +13 + +14 + +15 + +16 + +![Diagram showing the representation of block floating point compression. It illustrates two stages: the initial state with 32 sampling points (I0 to I31 and Q0 to Q31) and the compressed state where a shared exponent is used for all samples.](06fff3f2835e01abaac189c199b21399_img.jpg) + +The diagram illustrates the process of block floating point compression. It shows two states of 32 sampling points after compression. In the top state, each sample is represented by a pair of values (I and Q), with ellipses indicating intermediate samples. In the bottom state, the same 32 sampling points are shown, but the Q values are grouped under a shared 'Exponent' field, indicating that the mantissa values are shared across the block. + +Diagram showing the representation of block floating point compression. It illustrates two stages: the initial state with 32 sampling points (I0 to I31 and Q0 to Q31) and the compressed state where a shared exponent is used for all samples. + +Figure Annex2- 8 : Representation of block floating point compression + +17 + +![Flowchart showing the process of block floating point compression: Signed integer representation of IQ data value -> Find the maximum amplitude value of IQ data -> Use the shared exponent to calculate the mantissa -> Output the compressed IQ data.](ca79a5cbc68b21d6446ba7caebcbc509_img.jpg) + +``` + +graph LR + A[Signed integer representation of IQ data value] --> B[Find the maximum amplitude value of IQ data] + B --> C[Use the shared exponent to calculate the mantissa] + C --> D[Output the compressed IQ data] + +``` + +The flowchart describes the four steps of block floating point compression: 1. Signed integer representation of IQ data value, 2. Find the maximum amplitude value of IQ data, 3. Use the shared exponent to calculate the mantissa, and 4. Output the compressed IQ data. + +Flowchart showing the process of block floating point compression: Signed integer representation of IQ data value -> Find the maximum amplitude value of IQ data -> Use the shared exponent to calculate the mantissa -> Output the compressed IQ data. + +18 + +19 + +Figure Annex2- 9 Process of block floating point compression + +### A2.10.2 Block floating point compression algorithm + +The following is the pseudocode for a reference implementation of the compression algorithm. + +#### Input + +- fBlock - Original data block that is of the size of a compression block, for example, 32 samples with the original word length, each sample contains a 16 bits I sample data and a 16 bits Q sample data. +- iqWidth - Compressed word length (contains signed bit), for example, compressed I and Q are respectively represented by 8 bits. + +#### Output: + +- cBlock - Compressed data block. The size is a compression block, for example, 32 samples with the original word length +- exponent – shared exponent of compression block. I and Q samples use the same exponent which contains expWidth bits. For example, $\text{expWidth} = 1 + \log_2(16-8) = 4$ ; + +``` + +// Find max and min + $\text{maxV} = \max(\text{Re}(\text{fBlock}), \text{Im}(\text{fBlock}))$ , $\text{minV} = \min(\text{Re}(\text{fBlock}), \text{Im}(\text{fBlock}))$ + +// Determine max absolute value + $\text{maxValue} = \max(\text{maxV}, |\text{minV}| - 1)$ (msb of negative value can be one higher) + +// Calculate exponent + $\text{raw\_exp} = [\text{floor}(\log_2(\text{maxValue}) + 1)]$ (msb of $\text{maxValue}$ ) + +// Calculate shift value and limit to positive + $\text{exponent} = \max(\text{raw\_exp} - \text{iqWidth} + 1, 0)$ + +// Determine right shift value + $\text{scaler} = 2^{-\text{exponent}}$ + +For iSample = 1:length(fBlock) + //Scale and round: + Re(cBlock(iSample)) = Quantize ( $\text{scaler} \times \text{Re}(\text{fBlock}(\text{iSample}))$ ) /* mult. could be bit-shift, Quantize could be or-round */ + Im(cBlock(iSample)) = Quantize ( $\text{scaler} \times \text{Im}(\text{fBlock}(\text{iSample}))$ ) /* mult. could be bit-shift, Quantize could be or-round */ +End + +``` + +### A2.10.3 Block floating point decompression algorithm + +The following is the pseudocode for a reference implementation of the decompression algorithm. + +**Input:** + +- cBlock - Compressed data block, which contains, for example, 32 samples with word width iqWidth. +- exponent - Compressed data block 's shared exponent. + +**Output:** + +- fBlock - Decompressed data block, for example, 32 samples with the original word length, each sample contains a 16bits I sample data and a 16bits Q sample data. + +``` +//Determine scaler +scaler = 2exponent + +For iSample = 1:length(cBlock) + //Scale + Re(fBlock(iSample)) = scaler × Re(cBlock(iSample)) /* this could be replaced with a bit-shift operation */ + Im(fBlock(iSample)) = scaler × Im(cBlock(iSample)) /* this could be replaced with a bit-shift operation */ +End +``` + +## A2.11 Appendix - Typical mode of IQ mapping + +### A2.11.1 IQ mapping mode( line bit rate of 10137.6Mbps) + +This article presents the IQ mappings modes at a line bit rate of 10137.6Mbps for different scenarios. + +Scenario 1: One 5G cell with 4T4R antennas and 100M/80M bandwidth at line bit rate of 10137.6Mbps and one 4G cell with 2T2R antennas and 20M bandwidth at line bit rate of 10137.6Mbps, whose IQ data mapping mode is shown in the figure below. The W=1, #Z.X.0-2 area is compression information data(compression block 's shared exponent) area, The W=15, #Z.X.17-19 area is AGC area. The order of data for antennas in each of these two areas is the same as the order in IQ data area. + +| | | | | | | | | | | | | | | | | | | | +|---------------|---------|-----|-----|-----|------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|------| +| | #Z.X.0 | | | | AXC6 | AXC16 | AXC26 | AXC4 | AXC14 | AXC24 | AXC2 | AXC12 | AXC22 | AXC0 | AXC10 | AXC20 | AXC30 | AXC0 | +| | #Z.X.1 | | | | | | | | | | | | | | | | | | +| | #Z.X.2 | | | | AXC7 | AXC17 | AXC27 | AXC5 | AXC15 | AXC25 | AXC3 | AXC13 | AXC23 | AXC1 | AXC11 | AXC21 | AXC31 | AXC1 | +| | #Z.X.3 | R | R | | | | | | | | | | | | | | | | +| | #Z.X.4 | R | R | | AXC8 | AXC18 | AXC28 | AXC6 | AXC16 | AXC26 | AXC4 | AXC14 | AXC24 | AXC2 | AXC12 | AXC22 | AXC0 | AXC2 | +| | #Z.X.5 | R | R | | | | | | | | | | | | | | | | +| NR A0C1 | #Z.X.6 | R | R | | AXC9 | AXC19 | AXC29 | AXC7 | AXC17 | AXC27 | AXC5 | AXC15 | AXC25 | AXC3 | AXC13 | AXC23 | AXC1 | AXC3 | +| NR A1C1 | #Z.X.7 | R | R | | | | | | | | | | | | | | | | +| NR A2C1 | #Z.X.8 | | | | AXC0 | AXC10 | AXC20 | AXC30 | AXC8 | AXC18 | AXC28 | AXC6 | AXC16 | AXC26 | AXC4 | AXC14 | AXC24 | AXC2 | +| NR A3C1 | #Z.X.9 | | | | | | | | | | | | | | | | | | +| | #Z.X.10 | | | | AXC1 | AXC11 | AXC21 | AXC31 | AXC9 | AXC19 | AXC29 | AXC7 | AXC17 | AXC27 | AXC5 | AXC15 | AXC25 | AXC3 | +| | #Z.X.11 | | | | | | | | | | | | | | | | | | +| LTE A0C2 | #Z.X.12 | | | | AXC2 | AXC12 | AXC22 | AXC0 | AXC10 | AXC20 | AXC30 | AXC8 | AXC18 | AXC28 | AXC6 | AXC16 | AXC26 | AXC4 | +| LTE A1C2 | #Z.X.13 | | | | | | | | | | | | | | | | | | +| Reserved area | #Z.X.14 | | | | AXC3 | AXC13 | AXC23 | AXC1 | AXC11 | AXC21 | AXC31 | AXC9 | AXC19 | AXC29 | AXC7 | AXC17 | AXC27 | AXC5 | +| | #Z.X.15 | | | | | | | | | | | | | | | | | | +| AGC | #Z.X.16 | | | | AXC4 | AXC14 | AXC24 | AXC2 | AXC12 | AXC22 | AXC0 | AXC10 | AXC20 | AXC30 | AXC8 | AXC18 | AXC28 | AXC6 | +| | #Z.X.17 | | | | | | | | | | | | | | | | | | +| | #Z.X.18 | | | | AXC5 | AXC15 | AXC25 | AXC3 | AXC13 | AXC23 | AXC1 | AXC11 | AXC21 | AXC31 | AXC9 | AXC19 | AXC29 | AXC7 | +| | #Z.X.19 | | | | | | | | | | | | | | | | | | +| | W=0 | W=1 | W=2 | W=3 | W=4 | W=5 | W=6 | W=7 | W=8 | W=9 | W=10 | W=11 | W=12 | W=13 | W=14 | W=15 | | | + +**Figure Annex2- 10: Dual mode IQ data compression at a line rate of 10137.6Mbps** + +Situation 2 : IQ data compression of two neighborhoods by 2T2R with 100M/80M bandwidth at a line rate of 10137.6Mbps is shown in the figure below. The W=1, #Z.X.0-1 area is compression information data (compression block's public index) area, The W=15, #Z.X.18-19 area is AGC area. The marshalling sequence of the internal antennas of each of the two areas is the same as marshalling sequence of antennas of IQ data area. + +| | | | | | | | | | | | | | | | | | | | +|---------|---------|-----|-----|-----|------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|---| +| | #Z.X.0 | | | | AXC6 | AXC16 | AXC26 | AXC4 | AXC14 | AXC24 | AXC2 | AXC12 | AXC22 | AXC0 | AXC10 | AXC20 | AXC30 | R | +| | #Z.X.1 | | | | | | | | | | | | | | | | | R | +| | #Z.X.2 | R | R | | AXC7 | AXC17 | AXC27 | AXC5 | AXC15 | AXC25 | AXC3 | AXC13 | AXC23 | AXC1 | AXC11 | AXC21 | AXC31 | R | +| | #Z.X.3 | R | R | | | | | | | | | | | | | | | R | +| | #Z.X.4 | R | R | | AXC8 | AXC18 | AXC28 | AXC6 | AXC16 | AXC26 | AXC4 | AXC14 | AXC24 | AXC2 | AXC12 | AXC22 | R | R | +| | #Z.X.5 | R | R | | | | | | | | | | | | | | | R | +| NR A0C1 | #Z.X.6 | R | R | | AXC9 | AXC19 | AXC29 | AXC7 | AXC17 | AXC27 | AXC5 | AXC15 | AXC25 | AXC3 | AXC13 | AXC23 | R | R | +| NR A1C1 | #Z.X.7 | R | R | | | | | | | | | | | | | | | R | +| NR A0C2 | #Z.X.8 | | | | AXC0 | AXC10 | AXC20 | AXC30 | AXC8 | AXC18 | AXC28 | AXC6 | AXC16 | AXC26 | AXC4 | AXC14 | AXC24 | R | +| NR A1C2 | #Z.X.9 | | | | | | | | | | | | | | | | | R | +| | #Z.X.10 | | | | AXC1 | AXC11 | AXC21 | AXC31 | AXC9 | AXC19 | AXC29 | AXC7 | AXC17 | AXC27 | AXC5 | AXC15 | AXC25 | R | +| | #Z.X.11 | | | | | | | | | | | | | | | | | R | +| | #Z.X.12 | | | | AXC2 | AXC12 | AXC22 | AXC0 | AXC10 | AXC20 | AXC30 | AXC8 | AXC18 | AXC28 | AXC6 | AXC16 | AXC26 | R | +| | #Z.X.13 | | | | | | | | | | | | | | | | | R | +| | #Z.X.14 | | | | AXC3 | AXC13 | AXC23 | AXC1 | AXC11 | AXC21 | AXC31 | AXC9 | AXC19 | AXC29 | AXC7 | AXC17 | AXC27 | R | +| | #Z.X.15 | | | | | | | | | | | | | | | | | R | +| | #Z.X.16 | | | | AXC4 | AXC14 | AXC24 | AXC2 | AXC12 | AXC22 | AXC0 | AXC10 | AXC20 | AXC30 | AXC8 | AXC18 | AXC28 | R | +| | #Z.X.17 | | | | | | | | | | | | | | | | | R | +| | #Z.X.18 | | | | AXC5 | AXC15 | AXC25 | AXC3 | AXC13 | AXC23 | AXC1 | AXC11 | AXC21 | AXC31 | AXC9 | AXC19 | AXC29 | R | +| | #Z.X.19 | | | | | | | | | | | | | | | | | R | +| | W=0 | W=1 | W=2 | W=3 | W=4 | W=5 | W=6 | W=7 | W=8 | W=9 | W=10 | W=11 | W=12 | W=13 | W=14 | W=15 | | | + +**Figure Annex2- 11 : IQ data compression of two neighborhoods by 2T2R with 100M bandwidth at a line rate of 10137.6Mbps** + +Situation 3: IQ data compression of one neighborhood by 4T4R with 100M/80M bandwidth at a line rate of 10137.6Mbps is shown in the figure below. The W=1, #Z.X.0-1 area is compression information data (compression + +block's public index) area, The W=15, #Z.X.18-19 area is AGC area. The marshalling sequence of the internal antennas of each of the two areas is the same as marshalling sequence of antennas of IQ data area. + +| | | | | | | | | | | | | | | | | | | +|---------|------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|---| +| #Z.X.0 | | | | AXC6 | AXC16 | AXC26 | AXC4 | AXC14 | AXC24 | AXC2 | AXC12 | AXC22 | AXC0 | AXC10 | AXC20 | AXC30 | R | +| #Z.X.1 | | | | | | | | | | | | | | | | | R | +| #Z.X.2 | R | R | | AXC7 | AXC17 | AXC27 | AXC5 | AXC15 | AXC25 | AXC3 | AXC13 | AXC23 | AXC1 | AXC11 | AXC21 | AXC31 | R | +| #Z.X.3 | R | R | | | | | | | | | | | | | | | R | +| #Z.X.4 | R | R | | AXC8 | AXC18 | AXC28 | AXC6 | AXC16 | AXC26 | AXC4 | AXC14 | AXC24 | AXC2 | AXC12 | AXC22 | | R | +| #Z.X.5 | R | R | | | | | | | | | | | | | | | R | +| #Z.X.6 | R | R | | AXC9 | AXC19 | AXC29 | AXC7 | AXC17 | AXC27 | AXC5 | AXC15 | AXC25 | AXC3 | AXC13 | AXC23 | | R | +| #Z.X.7 | R | R | | | | | | | | | | | | | | | R | +| #Z.X.8 | | | | AXC0 | AXC10 | AXC20 | AXC30 | AXC8 | AXC18 | AXC28 | AXC6 | AXC16 | AXC26 | AXC4 | AXC14 | AXC24 | R | +| #Z.X.9 | | | | | | | | | | | | | | | | | R | +| #Z.X.10 | AXC1 | AXC11 | AXC21 | AXC31 | AXC9 | AXC19 | AXC29 | AXC7 | AXC17 | AXC27 | AXC5 | AXC15 | AXC25 | | | | R | +| #Z.X.11 | | | | | | | | | | | | | | | | | R | +| #Z.X.12 | AXC2 | AXC12 | AXC22 | AXC0 | AXC10 | AXC20 | AXC30 | AXC8 | AXC18 | AXC28 | AXC6 | AXC16 | AXC26 | | | | R | +| #Z.X.13 | | | | | | | | | | | | | | | | | R | +| #Z.X.14 | AXC3 | AXC13 | AXC23 | AXC1 | AXC11 | AXC21 | AXC31 | AXC9 | AXC19 | AXC29 | AXC7 | AXC17 | AXC27 | | | | R | +| #Z.X.15 | | | | | | | | | | | | | | | | | R | +| #Z.X.16 | AXC4 | AXC14 | AXC24 | AXC2 | AXC12 | AXC22 | AXC0 | AXC10 | AXC20 | AXC30 | AXC8 | AXC18 | AXC28 | | | | R | +| #Z.X.17 | | | | | | | | | | | | | | | | | R | +| #Z.X.18 | AXC5 | AXC15 | AXC25 | AXC3 | AXC13 | AXC23 | AXC1 | AXC11 | AXC21 | AXC31 | AXC9 | AXC19 | AXC29 | | | | R | +| #Z.X.19 | | | | | | | | | | | | | | | | | R | +| W=0 | W=1 | W=2 | W=3 | W=4 | W=5 | W=6 | W=7 | W=8 | W=9 | W=10 | W=11 | W=12 | W=13 | W=14 | W=15 | | | + +**Figure Annex2- 12 : IQ data compression of one neighborhood by 4T4R with 100M bandwidth at a line rate of 10137.6Mbps** + +Situation 4: IQ data compression of one neighborhood by 2T2R with 100M/80M bandwidth at a line rate of 10137.6Mbps is shown in the figure below. The W=1, #Z.X.0 area is compression information data (compression block's public index) area, The W=15, #Z.X.19 area is AGC area. The marshalling sequence of the internal antennas of each of the two areas is the same as marshalling sequence of antennas of IQ data area. + +| | | | | | | | | | | | | | | | | | | +|---------|------|-------|-------|-------|-------|-------|-------|-------|-------|-------|------|------|------|------|------|---|---| +| #Z.X.0 | | | | AXC6 | AXC16 | AXC26 | AXC4 | AXC14 | AXC24 | R | R | R | R | R | R | R | R | +| #Z.X.1 | R | R | | | | | | | | R | R | R | R | R | R | R | R | +| #Z.X.2 | R | R | | AXC7 | AXC17 | AXC27 | AXC5 | AXC15 | AXC25 | R | R | R | R | R | R | R | R | +| #Z.X.3 | R | R | | | | | | | | R | R | R | R | R | R | R | R | +| #Z.X.4 | R | R | | AXC8 | AXC18 | AXC28 | AXC6 | AXC16 | AXC26 | R | R | R | R | R | R | R | R | +| #Z.X.5 | R | R | | | | | | | | R | R | R | R | R | R | R | R | +| #Z.X.6 | R | R | | AXC9 | AXC19 | AXC29 | AXC7 | AXC17 | AXC27 | R | R | R | R | R | R | R | R | +| #Z.X.7 | R | R | | | | | | | | R | R | R | R | R | R | R | R | +| #Z.X.8 | | | | AXC0 | AXC10 | AXC20 | AXC30 | AXC8 | AXC18 | AXC28 | R | R | R | R | R | R | R | +| #Z.X.9 | | | | | | | | | | R | R | R | R | R | R | R | R | +| #Z.X.10 | AXC1 | AXC11 | AXC21 | AXC31 | AXC9 | AXC19 | AXC29 | | | R | R | R | R | R | R | R | R | +| #Z.X.11 | | | | | | | | | | R | R | R | R | R | R | R | R | +| #Z.X.12 | AXC2 | AXC12 | AXC22 | AXC0 | AXC10 | AXC20 | AXC30 | | | R | R | R | R | R | R | R | R | +| #Z.X.13 | | | | | | | | | | R | R | R | R | R | R | R | R | +| #Z.X.14 | AXC3 | AXC13 | AXC23 | AXC1 | AXC11 | AXC21 | AXC31 | | | R | R | R | R | R | R | R | R | +| #Z.X.15 | | | | | | | | | | R | R | R | R | R | R | R | R | +| #Z.X.16 | AXC4 | AXC14 | AXC24 | AXC2 | AXC12 | AXC22 | | | | R | R | R | R | R | R | R | R | +| #Z.X.17 | | | | | | | | | | R | R | R | R | R | R | R | R | +| #Z.X.18 | AXC5 | AXC15 | AXC25 | AXC3 | AXC13 | AXC23 | | | | R | R | R | R | R | R | R | R | +| #Z.X.19 | | | | | | | | | | R | R | R | R | R | R | R | R | +| W=0 | W=1 | W=2 | W=3 | W=4 | W=5 | W=6 | W=7 | W=8 | W=9 | W=10 | W=11 | W=12 | W=13 | W=14 | W=15 | | | + +**Figure Annex2- 13 : IQ data compression of one neighborhood by 2T2R with 100M bandwidth at a line rate of 10137.6Mbps** + +### A2.11.2 IQ mapping mode( a line rate of 12165.12Mbps) + +Image: O-RAN Alliance Logo + +ORAN.WG7.IPC-HRD-Opt8.0-v03.00 + +Situation 1: One NR neighborhood by 4T4R with 100M bandwidth at a line rate of 12165.12Mbps and two LTE neighborhoods by 2T2R with 20M bandwidth at a line rate of 12165.12Mbps, who's the IQ data mapping mode is shown in the figure below in the situation. The W=1, #Z.X.0-3 area is compression information data (compression block's public index) area, The W=15, #Z.X.20-23 area is AGC area. The marshalling sequence of the internal antennas of each of the two areas is the same as marshalling sequence of antennas of IQ data area. + +![](42979da227339b730bfc23d4f02d6da7_img.jpg) + +| | | | | | | | | | | | | | | | | | | +|----------------------|---------|-----|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|------|------|------| +| NR A0C1 | #Z.X.0 | | AXC8 | AXC20 | AXC0 | AXC12 | AXC24 | AXC4 | AXC16 | AXC28 | AXC8 | AXC20 | AXC0 | AXC4 | AXC0 | R | | +| | #Z.X.1 | | AXC9 | AXC21 | AXC1 | AXC13 | AXC25 | AXC5 | AXC17 | AXC29 | AXC9 | AXC21 | AXC1 | AXC5 | AXC1 | R | | +| | #Z.X.2 | | | | | | | | | | | | | | | R | | +| | #Z.X.3 | | AXC10 | AXC22 | AXC2 | AXC14 | AXC26 | AXC6 | AXC18 | AXC30 | AXC10 | AXC22 | AXC2 | AXC6 | AXC2 | R | | +| NR A1C1 | #Z.X.4 | R | | | | | | | | | | | | | | R | R | +| | #Z.X.5 | R | | | | | | | | | | | | | | R | R | +| | #Z.X.6 | R | R | AXC11 | AXC23 | AXC3 | AXC15 | AXC27 | AXC7 | AXC19 | AXC31 | AXC11 | AXC23 | AXC3 | AXC7 | AXC3 | R | +| | #Z.X.7 | R | R | | | | | | | | | | | | | | R | +| NR A2C1 | #Z.X.8 | | | | | | | | | | | | | | | | R | +| | #Z.X.9 | | | AXC0 | AXC12 | AXC24 | AXC4 | AXC16 | AXC28 | AXC8 | AXC20 | AXC0 | AXC12 | AXC24 | AXC0 | AXC4 | R | +| NR A3C1 | #Z.X.10 | | | | | | | | | | | | | | | | R | +| | #Z.X.11 | | | | | | | | | | | | | | | | R | +| LTE A0C2<br>LTE A1C2 | #Z.X.12 | | | AXC1 | AXC13 | AXC25 | AXC5 | AXC17 | AXC29 | AXC9 | AXC21 | AXC1 | AXC13 | AXC25 | AXC5 | AXC5 | R | +| | #Z.X.13 | | | | | | | | | | | | | | | | R | +| LTE A0C3<br>LTE A1C3 | #Z.X.14 | | | | | | | | | | | | | | | | R | +| | #Z.X.15 | | | AXC2 | AXC14 | AXC26 | AXC6 | AXC18 | AXC30 | AXC10 | AXC22 | AXC2 | AXC14 | AXC26 | AXC6 | AXC6 | R | +| Reserved area | #Z.X.16 | | | | | | | | | | | | | | | | R | +| | #Z.X.17 | | | | | | | | | | | | | | | | R | +| AGC | #Z.X.18 | | | AXC3 | AXC15 | AXC27 | AXC7 | AXC19 | AXC31 | AXC11 | AXC23 | AXC3 | AXC15 | AXC27 | AXC7 | AXC7 | R | +| | #Z.X.19 | | | | | | | | | | | | | | | | R | +| | #Z.X.20 | | | | | | | | | | | | | | | | R | +| | #Z.X.21 | | | AXC4 | AXC16 | AXC28 | AXC8 | AXC20 | AXC0 | AXC12 | AXC24 | AXC4 | AXC16 | AXC28 | AXC8 | AXC0 | R | +| | #Z.X.22 | | | | | | | | | | | | | | | | R | +| | #Z.X.23 | | | | | | | | | | | | | | | | R | +| | | W=0 | W=1 | W=2 | W=3 | W=4 | W=5 | W=6 | W=7 | W=8 | W=9 | W=10 | W=11 | W=12 | W=13 | W=14 | W=15 | + +**Figure Annex2- 14 : Dual mode IQ data compression at a line rate of 12165.12Mbps** + +## A2.11.3 IQ mapping mode( a line rate of 24330.24Mbps) + +This article presents the IQ mappings modes at a line rate of 24330.24Mbps for different situation. + +Situation 1: Two NR neighborhoods by 4T4R with 100M/80M bandwidth at a line rate of 24330.24Mbps and two LTE neighborhoods by 2T2R with 20M bandwidth at a line rate of 24330.24Mbps, whose IQ data mapping mode is shown in the figure below in the situation. The W=1, #Z.X.0-5 area is compression information data (compression block's public index) area, The W=15, #Z.X.42-47 area is AGC area. The marshalling sequence of the internal antennas of each of the two areas is the same as marshalling sequence of antennas of IQ data area. + +Copyright © 2021 O-RAN ALLIANCE e.V. + +89 + +Your use is subject to the terms of the O-RAN Adopter License Agreement in Annex ZZZ + +![Figure Annex2- 15: Dual mode IQ data compression at a line rate of 24330.24Mbps. The figure shows a grid of antenna configurations for two neighborhoods (W=1 and W=15) across various frequency bands (NR A0C1, NR A1C1, NR A2C1, NR A3C1, NR A0C2, NR A1C2, NR A2C2, NR A3C2, LTE A0C3, LTE A1C3, LTE A0C4, LTE A1C4, Reserved area, AGC). The grid is organized by frequency band and antenna index, with columns representing different antenna configurations and rows representing different frequency bands. The W=1 area is on the left, and the W=15 area is on the right. The AGC area is at the bottom right.](ff2a28b810dfe861ccb6f9fb77db04b8_img.jpg) + +| Band | W=1 | W=2 | W=3 | W=4 | W=5 | W=6 | W=7 | W=8 | W=9 | W=10 | W=11 | W=12 | W=13 | W=14 | W=15 | +|---------------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------| +| NR A0C1 | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | +| NR A1C1 | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | AXC13 | AXC5 | +| NR A2C1 | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | +| NR A3C1 | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | AXC15 | AXC7 | +| NR A0C2 | AXC0 | AXC24 | AXC16 | AXC8 | AXC0 | AXC24 | AXC16 | AXC8 | AXC0 | AXC24 | AXC16 | AXC8 | AXC0 | AXC24 | AXC16 | +| NR A1C2 | AXC1 | AXC25 | AXC17 | AXC9 | AXC1 | AXC25 | AXC17 | AXC9 | AXC1 | AXC25 | AXC17 | AXC9 | AXC1 | AXC25 | AXC17 | +| NR A2C2 | AXC2 | AXC26 | AXC18 | AXC10 | AXC2 | AXC26 | AXC18 | AXC10 | AXC2 | AXC26 | AXC18 | AXC10 | AXC2 | AXC26 | AXC18 | +| NR A3C2 | AXC3 | AXC27 | AXC19 | AXC11 | AXC3 | AXC27 | AXC19 | AXC11 | AXC3 | AXC27 | AXC19 | AXC11 | AXC3 | AXC27 | AXC19 | +| LTE A0C3 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | +| LTE A1C3 | AXC5 | AXC29 | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | +| LTE A0C4 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | +| LTE A1C4 | AXC7 | AXC31 | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | +| Reserved area | R | R | R | R | R | R | R | R | R | R | R | R | R | R | R | +| AGC | AGC | AGC | AGC | AGC | AGC | AGC | AGC | AGC | AGC | AGC | AGC | AGC | AGC | AGC | AGC | + +Figure Annex2- 15: Dual mode IQ data compression at a line rate of 24330.24Mbps. The figure shows a grid of antenna configurations for two neighborhoods (W=1 and W=15) across various frequency bands (NR A0C1, NR A1C1, NR A2C1, NR A3C1, NR A0C2, NR A1C2, NR A2C2, NR A3C2, LTE A0C3, LTE A1C3, LTE A0C4, LTE A1C4, Reserved area, AGC). The grid is organized by frequency band and antenna index, with columns representing different antenna configurations and rows representing different frequency bands. The W=1 area is on the left, and the W=15 area is on the right. The AGC area is at the bottom right. + +Figure Annex2- 15 : Dual mode IQ data compression at a line rate of 24330.24Mbps + +Situation 2: IQ data compression of two neighborhoods by 4T4R with 100M/80M bandwidth at a line rate of 24330.24Mbps is shown in the figure below. The W=1, #Z.X.0-3 area is compression information data (compression block's public index) area, The W=15, #Z.X.44-47 area is AGC area. The marshalling sequence of the internal antennas of each of the two areas is the same as marshalling sequence of antennas of IQ data area. + +Image: O-RAN Alliance Logo + +ORAN.WG7.IPC-HRD-Opt8.0-v03.00 + +| | W=0 | W=1 | W=2 | W=3 | W=4 | W=5 | W=6 | W=7 | W=8 | W=9 | W=10 | W=11 | W=12 | W=13 | W=14 | W=15 | +|---------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|-------|------|------|------|------| +| #Z.X.0 | | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | AXC12 | R | R | R | R | | +| #Z.X.1 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.2 | | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | AXC13 | R | R | R | R | | +| #Z.X.3 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.4 | R | R | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | AXC14 | R | R | R | R | +| #Z.X.5 | R | R | | | | | | | | | | | R | R | R | R | +| #Z.X.6 | R | R | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | AXC15 | R | R | R | R | +| #Z.X.7 | R | R | | | | | | | | | | | R | R | R | R | +| #Z.X.8 | AXC0 | AXC24 | AXC16 | AXC8 | AXC0 | AXC24 | AXC16 | AXC8 | AXC0 | AXC24 | AXC16 | R | R | R | R | | +| #Z.X.9 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.10 | | AXC25 | AXC17 | AXC9 | AXC1 | AXC25 | AXC17 | AXC9 | AXC1 | AXC25 | AXC17 | R | R | R | R | | +| #Z.X.11 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.12 | AXC2 | AXC26 | AXC18 | AXC10 | AXC2 | AXC26 | AXC18 | AXC10 | AXC2 | AXC26 | AXC18 | R | R | R | R | | +| #Z.X.13 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.14 | | AXC27 | AXC19 | AXC11 | AXC3 | AXC27 | AXC19 | AXC11 | AXC3 | AXC27 | AXC19 | R | R | R | R | | +| #Z.X.15 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.16 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | R | R | R | R | | +| #Z.X.17 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.18 | | AXC29 | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | R | R | R | R | | +| #Z.X.19 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.20 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | R | R | R | R | | +| #Z.X.21 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.22 | | AXC31 | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | R | R | R | R | | +| #Z.X.23 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.24 | AXC8 | AXC0 | AXC24 | AXC16 | AXC8 | AXC0 | AXC24 | AXC16 | AXC8 | AXC0 | AXC24 | R | R | R | R | | +| #Z.X.25 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.26 | | AXC1 | AXC25 | AXC17 | AXC9 | AXC1 | AXC25 | AXC17 | AXC9 | AXC1 | AXC25 | R | R | R | R | | +| #Z.X.27 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.28 | AXC10 | AXC2 | AXC26 | AXC18 | AXC10 | AXC2 | AXC26 | AXC18 | AXC10 | AXC2 | AXC26 | R | R | R | R | | +| #Z.X.29 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.30 | | AXC3 | AXC27 | AXC19 | AXC11 | AXC3 | AXC27 | AXC19 | AXC11 | AXC3 | AXC27 | R | R | R | R | | +| #Z.X.31 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.32 | AXC12 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | AXC28 | AXC20 | AXC12 | AXC4 | AXC28 | R | R | R | R | | +| #Z.X.33 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.34 | | AXC5 | AXC29 | AXC21 | AXC13 | AXC5 | AXC29 | AXC21 | AXC13 | AXC5 | AXC29 | R | R | R | R | | +| #Z.X.35 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.36 | AXC14 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | AXC30 | AXC22 | AXC14 | AXC6 | AXC30 | R | R | R | R | | +| #Z.X.37 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.38 | | AXC7 | AXC31 | AXC23 | AXC15 | AXC7 | AXC31 | AXC23 | AXC15 | AXC7 | AXC31 | R | R | R | R | | +| #Z.X.39 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.40 | AXC16 | AXC8 | AXC0 | AXC24 | AXC16 | AXC8 | AXC0 | AXC24 | AXC16 | AXC8 | AXC0 | R | R | R | R | | +| #Z.X.41 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.42 | | AXC9 | AXC1 | AXC25 | AXC17 | AXC9 | AXC1 | AXC25 | AXC17 | AXC9 | AXC1 | R | R | R | R | | +| #Z.X.43 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.44 | AXC18 | AXC10 | AXC2 | AXC26 | AXC18 | AXC10 | AXC2 | AXC26 | AXC18 | AXC10 | AXC2 | R | R | R | R | | +| #Z.X.45 | | | | | | | | | | | | R | R | R | R | | +| #Z.X.46 | | AXC11 | AXC3 | AXC27 | AXC19 | AXC11 | AXC3 | AXC27 | AXC19 | AXC11 | AXC3 | R | R | R | R | | +| #Z.X.47 | | | | | | | | | | | | R | R | R | R | | + +**Figure Annex2- 16 : IQ data compression of two neighborhoods by 4T4R with 100M/80M bandwidth at a line rate of 24330.24Mbps** + +--- + +Copyright © 2021 O-RAN ALLIANCE e.V. +91 + + +Your use is subject to the terms of the O-RAN Adopter License Agreement in Annex ZZZ + +# Annex 3 Option 8 CPRI spec reference design – Management plane + +## A3.1 Scope + +This chapter includes management of O-RU<sub>s</sub> based on Option8 CPRI protocol connection. + +## A3.2 References + +- [1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications” +- [2] ORAN-WG4.MP.0-v03.00.00 +- [3] ORAN-WG4.CUS.0-v03.00 +- [4] RFC 6241, “Network Configuration Protocol (NETCONF)”, IETF, June 2011 +- [5] SFF-8472v11, “Diagnostic Monitoring Interface for Optical Transceivers”, SFF Committee, September 2010 +- [6] SFF-8636v2.9.3, “Specification for Management Interface for Cabled Environment”, SFF Committee, April 2019 +- [7] IEEE 802.1ag, “IEEE Standard for Local and Metropolitan Area Networks Virtual Bridged Local Area Networks Amendment 5: Connectivity Fault Management”, IEEE, 2007 +- [8] MEF.38, “Service OAM Fault management YANG Modules”, Metro Ethernet Forum, April 2012 +- [9] G.8275.1 Precision time protocol telecom profile for phase/time synchronization with full timing support from the network ITU June 2016. +- [10] G.810 Definitions and terminology for synchronization networks ITU August 1996.[11] 1588v2-2008 IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems IEEE 2008 + +## A3.3 Overview of NETCONF Configuration Management + +### A3.3.1 NETCONF RPC Basic Operation + +NETCONF operation layer RPC is shown as following table. + +**Table Annex3- 1 NETCOF basic operation** + +| Operation | Mandatory /Optional | Description | +|-----------------|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <get> | mandatory | for querying the status data, you can use the filter for conditional queries | +| <get-config> | mandatory | for querying configuration data | +| <edit-config> | mandatory | for modifying the contents of a specified configuration database, supported operations:<br><br>merge: a merging operation, which is a default operation<br><br>replace: a replacing operation, which replaces the object if it already exists, and creates one if it doesn't exist<br><br>create: a creating operation, an error "data-exists" is reported if the object already exists<br><br>delete: a deleting operation, which deletes the object if it exists, or an error "data-missing" is reported if it doesn't exist<br><br>remove: a removing operation, which removes the object if it exists, and the operation is ignored if it doesn't exist | +| <copy-config> | optional | for replicating a source database to a target database | +| <delete-config> | optional | for deleting a database, wherein a running database cannot be deleted | +| <lock> | optional | for getting a lock for a specified database, which is optional | + +| | | | +|-----------------|-----------|------------------------------------------------------------------| +| <unlock> | optional | for releasing a lock for a specified database, which is optional | +| <close-session> | mandatory | for closing gracefully a NETCONF connection | +| <kill-session> | mandatory | for closing compulsively a NETCONF connection | + +### A3.3.2 O-RAN Self-defining RPC Operation + +Self-defined RPC of O-RAN is in a content layer, as shown in following table: + +**Table Annex3- 2 Self-defined RPC of O-RAN** + +| RPC | Mandatory /Optional | Description | YANG Model | +|-----------------------------|---------------------|----------------------------------------------------------------------------------|----------------------------| +| activate-beamforming-config | optional | activating a beamforming configuration | o-ran-beamforming.yang | +| file-upload | mandatory | uploading files to O-DU <sub>8</sub> | o-ran-file-management.yang | +| retrieve-file-list | mandatory | obtaining a file list via O-DU <sub>8</sub> | o-ran-file-management.yang | +| file-download | mandatory | instructing O-RU <sub>8</sub> to download files via O-DU <sub>8</sub> | o-ran-file-management.yang | +| reset-interface-counters | optional | indicating O-RU <sub>8</sub> to reset an interface counter via O-DU <sub>8</sub> | o-ran-interfaces.yang | +| start-measurements | optional | indicating O-RU <sub>8</sub> to start a measurement via O-DU <sub>8</sub> | o-ran-laa-operations.yang | +| reset | mandatory | indicating O-RU <sub>8</sub> to restart via O-DU <sub>8</sub> | o-ran-operations.yang | +| software-download | mandatory | indicating O-RU <sub>8</sub> to download a | o-ran-software- | + +| | | | | +|----------------------------|-----------|-------------------------------------------------------------------------------------------|--------------------------------| +| | | specified software via O-DU <sub>8</sub> | management.yang | +| software-install | mandatory | indicating O-RU <sub>8</sub> to install a specified software via O-DU <sub>8</sub> | o-ran-software-management.yang | +| software-activate | mandatory | indicating O-RU <sub>8</sub> to activate a specified software via O-DU <sub>8</sub> | o-ran-software-management.yang | +| supervision-watchdog-reset | mandatory | resetting a “watchdog” timer of O-RU <sub>8</sub> by O-DU <sub>8</sub> | o-ran-supervision.yang | +| start-trace-logs | mandatory | triggering O-RU <sub>8</sub> to start to collect trace files | o-ran-trace.yang | +| stop-trace-logs | mandatory | Triggering O-RU <sub>8</sub> to stop collecting trace files | o-ran-trace.yang | +| start-troubleshooting-logs | mandatory | indicating O-RU <sub>8</sub> to start to collect fault location log via O-DU <sub>8</sub> | o-ran-troubleshooting.yang | +| stop-troubleshooting-logs | mandatory | indicating O-RU <sub>8</sub> to stop collecting fault location log via O-DU <sub>8</sub> | o-ran-troubleshooting.yang | +| chg-password | mandatory | resetting account passwords | o-ran-usermgmt.yang | + +1 + +## A3.4M-Plane Connection Establishment + +2 + +A process of establishing M-plane connections is described in this chapter, including: a network layer connection, a secure transport layer SSH connection, and a NETCONF connection. + +### A3.4.1 Specific Conventions + +DHCP related requirements refer to RFC2131, RFC2132 + +SSHv2 related requirements mainly refer to RFC4252, RFC4253 + +NETCONF connection related requirements refer to RFC8071, RFC6242, RFC8341 + +A comparison of the differences between this chapter and the O-RAN M-plane Specification [1] is shown in the following table. + +**Table Annex3- 3** + +| | O-RAN M-plane Specification | This Specification | +|-------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------|------------------------------------| +| O-RU <sub>s</sub> identification in DHCP | DHCPv4 Option 60;<br>DHCPv4 Option 124;<br>DHCPv6 Option 16 | only DHCPv4 Option 60 is supported | +| Detection discovery of M-plane client | DHCPv4<br>OPTION_V4_ZEROTOUCH_REDIRECT<br><br>DHCPv6<br>OPTION_V6_ZEROTOUCH_REDIRECT;<br><br>DHCPv4 Option 43;<br>DHCPv6 Option 17 | only DHCPv4 Option 43 is supported | +| Prefix of vendor-class of O-RU <sub>s</sub> | o-ran-ru<br>o-ran-ru2 | o-ran-ru | +| TCP port number for establishing SSH connection | Port 830 | supported | + +| | | | +|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------| +| Authentication way | password authentication<br>X.509 certificate | only password authentication is supported<br><br>default username: oranuser<br><br>default password: o-ran-password | +| User access privilege | sudo<br><br>nms<br><br>fm-pm<br><br>swm | only sudo is supported | +| NETCONF capability | Writable-running configuration capability<br><br>Candidate configuration capability and associated commit operation<br><br>Activation configuration capability<br><br>Discard change operation<br><br>Lock and un-lock operations<br><br>Confirmed commit capability<br><br>Cancel commit operation<br><br>Rollback on error capability<br><br>Validate capability<br><br>URL capability<br><br>XPath capability<br><br>Notifications<br><br>NETCONF session reuse capability | Writable-running configuration capability<br><br>XPath capability<br><br>Notifications<br><br>NETCONF session reuse capability | + +### A3.4.2 Pre-conditions of M-plane Connection + +Both ends of a CPRI link can be negotiated to a state F according to a specified configuration (see 4.3.1.CPRI Interface Management for details); Ethernet over CPRI is connected and can begin to establish a secure connection to an O-RU<sub>s</sub> M-plane. + +### A3.4.3 Network Layer Connection + +#### A3.4.3.1 O-RU<sub>8</sub> identification in DHCP + +When an IP address is assigned to the O-RU<sub>8</sub> or when O-RU<sub>8</sub> controller (O-DU<sub>8</sub>) information of an M-plane is configured in the O-RU<sub>8</sub>, a DHCP server uses this information. + +The DHCPv4 Option 60 Vendor Class Identifier as defined in RFC2132 can be used as identification of O-RU<sub>8</sub> in DHCPv4, as shown in following table: + +**Table Annex3- 4 DHCPv4 Vendor identifier** + +| DHCPv4 | | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Option | Vendor Class Option | +| | 60 | +| Vendor Class String | <p>“o-ran-ru/<vendor>“, such as “o-ran-ru/vendor”</p> <p>“o-ran-ru/<vendor>/<product-code>“, such as “o-ran-ru/vendorA/ORUAA100”</p> <p>“o-ran-ru/<vendor>/<product-code>/<serial-number>“, such as “o-ran-17ru2/vendorA/ORUAA100/FR1918010111”</p> | + +#### A3.4.3.2 VLAN detection and discovery + +In the current version of this specification, an untagged interface is used for sending and receiving messages of the M-plane by the M-plane. + +#### A3.4.3.3 IP address assignment + +Please refer to RFC2131 and RFC4361 for a DHCP discovery process which is involved in obtaining IP addresses of O-RU<sub>8</sub> M-plane. + +The IP address of O-RU<sub>8</sub> M-plane is assigned automatically, and the DHCP server should perform static binding operation, i.e., ensure that the same IP address of M-plane are always assigned to O- + +RU<sub>s</sub> identified by the same client hardware address, e.g., the IP address of M-plane assigned remains unchanged after an O-RU<sub>s</sub> reboot. + +#### A3.4.3.4 M-plane client detection and discovery + +The DHCP server uses Vendor Specific Option 43 of DHCPv4 to send NETCONF client information to O-RU<sub>s</sub>. + +Following table defines the encoding format for NETCONF client information when the prefix type of DHCPv4 Option 43 at the Vendor Class is o-ran-ru. + +Table Annex3- 5 TLV format of NETCONF client information + +| O-RU <sub>s</sub> uses an <b>o-ran-ru</b> prefix to report vendor-class | DHCPv4 Option 43 | | | +|-------------------------------------------------------------------------|----------------------------------------------------|-------------------------------------------------|------------------------| +| | Type | Length | Value | +| | Type: 0x01-O-RU <sub>s</sub> controller IP address | Hexadecimal encoding of a length value in bytes | Hexadecimal IP address | + +### A3.4.4 Secure Transport Layer SSH Connection + +#### A3.4.4.1 Establishing NETCONF Call Home M-plane TCP connection + +O-RU<sub>s</sub> initiates a NETCONF session to O-DU<sub>s</sub> after it obtains address information of M-plane and O-DU<sub>s</sub> (NETCONF client) information. If it fails to establish the session, the O-RU<sub>s</sub> will perform a Call Home process to O-DU<sub>s</sub> repeatedly and periodically according to a timer “recall-home-to-ssh-timer”, until the session is established successfully. + +Using port 4334 of NETCONF Call Home client O-DU<sub>s</sub> receives the Call Home TCP connection initiated by O-RU<sub>s</sub>, please refer to RFC8071 for the process. + +M-plane of a fronthaul interface is established by using a method of SSHv2 password authentication. + +#### A3.4.4.2 Establishing M-plane SSH connection + +The O-RU<sub>8</sub> serves as the SSHv2 server, and the O-DU<sub>8</sub> serves as the client. Before the O-RU<sub>8</sub> sends or receives password authentication-based data or any configuration/status data, the O-DU<sub>8</sub> (which is also a NETCONF client) should verify and authenticate O-RU<sub>8</sub>'s ID. + +The O-DU<sub>8</sub> authenticates the O-RU<sub>8</sub> by using public key-based host authentication. Refer to RFC4253 for the main process. + +The O-RU<sub>8</sub> shall verify and authenticate the O-DU<sub>8</sub>'s ID before it can receive any configuration or reporting status data sent by the O-DU<sub>8</sub>. Refer to RFC4253 for the main process. + +After the initialization of the starting system, the O-RU<sub>8</sub> is configured as a default account, e.g., the default user account is named "oranuser". + +It needs to define a default password for the default account and configure the default password in the O-RU<sub>8</sub>, for example, as "o-ran-password". + +### A3.4.5 NETCONF Connection + +#### A3.4.5.1 M-plane interchange capability set + +The O-RU<sub>8</sub> notifies its NETCONF capability in the NETCONF Hello message. The Hello message indicates standard features defined in the supported NETCONF RFC6241, as well as the specific namespace. + +The NETCONF capability for interaction between the O-RU<sub>8</sub> and the NETCONF client is shown in following table: + +**Table Annex3- 6 NETCONF capability support** + +| Capacity | Description | +|--------------------------------------------------------------------|-------------| +| writable-running configuration capability | support | +| candidate configuration capability and associated commit operation | optional | + +| | | +|-------------------------------------|-----------------------------------------------------------------------------------------------------------| +| activation configuration capability | optional | +| discard change operation | optional | +| lock and un-lock operations | optional | +| confirmed commit capability | optional (support if the candidate configuration capability and associated commit operation is supported) | +| Cancel commit operation | optional (support if the candidate configuration capability and associated commit operation is supported) | +| rollback on error capability | optional | +| validate capability | optional | +| URL capability | optional | +| XPATH capability | support | +| notifications | support | +| NETCONF session reuse capability | support | + +#### A3.4.5.2 Basic information query + +During the startup phase, after the NETCONF connection is established, by the NETCONF configuration query process, the O-DU<sub>8</sub> obtains the basic information of the O-RU<sub>8</sub> as follows: + +hw/hardware/component + +**mfg-name:** name of O-RU<sub>8</sub> manufacturer; + +**serial-num:** serial number of O-RU<sub>8</sub>; + +**software-rev:** O-RU<sub>8</sub> software component. + +o-ran-hardware/hardware/component/ + +**product-code:** product code defined by O-RAN; + +o-ran-operations/operational-info/declarations + +**supported-mplane-version:** version of O-RAN M-plane interface; + +**supported-cusplane-version:** version of O-RAN CUS-plane interface; + +**supported-header-mechanism:** type of CU-plane message header supported by O-RU<sub>8</sub>; + +o-ran-operations/operational-state + +**restart-cause:** reasons for the most recent reboot; + +o-ran-sync/sync + +**sync-state:** synch state of O-RU<sub>8</sub>. + +#### A3.4.5.3 Access privilege of M-plane + +In order to support interoperability of management control of the fronthaul interface, the O-RU<sub>8</sub>, which serves as an NETCONF server, should use the IETF NETCONF Access 34 Control Model defined by RFC8341. + +The O-DU<sub>8</sub> accesses the O-RU<sub>8</sub> as a NETCONF Client [A1], and uses “sudo” privilege. + +Following table defines model operation privilege for the sudo user. + +**Table Annex3- 7 NETCONF capability support** + +| Model rules | Sudo user | +|---------------------------------------------|------------| +| “urn:o-ran:supervision:x.y” | --X | +| “urn:o-ran:hardware:x.y” | R-X | +| “urn:ietf:params:xml:ns:yang:ietf-hardware” | RWX | +| “urn:ietf:params:xml:ns:yang:iana-hardware” | RWX | +| “urn:o-ran:user-mgmt:x.y” | RW- note 1 | +| “urn:o-ran:fm: x.y” | R-X | +| “urn:o-ran:fan: x.y ” | R-- | +| “urn:o-ran:sync: x.y ” | RW- | +| “urn:o-ran:delay: x.y” | RW- | +| “urn:o-ran:module-cap: x.y ” | R-- | +| “urn:o-ran:udpecho: x.y ” | RW- | +| “urn:o-ran:operations: x.y ” | R-X | +| “urn:o-ran:uplane-conf: x.y ” | RWX | +| “urn:o-ran:beamforming: x.y” | RWX | + +| | | +|-----------------------------------------------------------------------|-----| +| “urn:o-ran:lbm: x.y” | RWX | +| “urn:o-ran:software-management: x.y” | RWX | +| “urn:o-ran:file-management: x.y” | --X | +| “urn:o-ran:message5: x.y ” | RW- | +| “urn:o-ran:performance-management: x.y ” | RWX | +| “urn:o-ran:transceiver: x.y ” | RW- | +| “urn:o-ran:externalio: x.y ” | RWX | +| “urn:o-ran:ald-port: x.y ” | RWX | +| “urn:o-ran:interfaces: x.y ” | RWX | +| “urn:ietf:params:xml:ns:yang:ietf-ip” | RW- | +| “urn:ietf:params:xml:ns:yang:ietf-interfaces” | RW- | +| “urn:ietf:params:xml:ns:yang:iana-if-type” | R-- | +| “urn:ietf:params:xml:ns:yang:ietf-inet-types” | R-- | +| “urn:o-ran:processing-elements: x.y” | RW- | +| “urn:o-ran:mplane-interfaces: x.y” | RW- | +| “urn:o-ran:dhcp: x.y “ | R-- | +| “urn:ietf:params:xml:ns:yang:ietf-dhcpv6-types” | RW- | +| “urn:o-ran:ald: x.y” | --X | +| “urn:o-ran:troubleshooting: x.y” | --X | +| “urn:o-ran:trace: x.y” | --X | +| “urn:o-ran:laa: x.y” | RW- | +| “urn:o-ran:laa-operations: x.y” | --X | +| “urn:o-ran:antcal: x.y” | RWX | +| “urn:ietf:params:xml:ns:yang:ietf-netconf-acm” | RWX | +| “urn:ietf:params:xml:ns:yang:ietf-yang-library” | RWX | +| “urn:ietf:params:xml:ns:yang:ietf-netconf-monitoring” | RWX | +| Note 1: the rule list for “urn:o-ran:usermgmt:1.0” denies any NETCONF | | + +client to read the password leaf node. + +#### A3.4.5.4 Configuring user account + +The accounts are all sudo privileges. + +Username: a string of 3-32 characters, the first character must be a lowercase letter, and the rest can be lowercase letters or numbers. + +Password: a string of 8-128 characters. Characters allowed in the password field include upper and lower case letters, numbers, and special characters: ! \$ % ^ ( ) \_ + ~ { } [ ] . -. + +The O-RU<sub>8</sub> configures a default account, for example, the account name of the default user is “oranuser”. + +The default account has an account type PASSWORD, in which case the default password needs to be defined and configured in O-RU<sub>8</sub>, e.g., “o-ran-password”. + +#### A3.4.5.5 Keeping M-plane connection alive + +When performing a session with an O-DU<sub>8</sub> (NETCONF Client) with “sudo” access privileges, the O-RU<sub>8</sub> operates a “watchdog” timer to monitor durability of the session with the O-DU<sub>8</sub> (NETCONF Client). The O-RU<sub>8</sub> indicates the O-DU<sub>8</sub> (NETCONF Client) that its management system is running via NETCONF notifications. + +Whenever the O-RU<sub>8</sub> establishes a NETCONF session with an O-DU<sub>8</sub> with “sudo” privileges, the O-DU<sub>8</sub> shall enable the “watchdog” timer by creating a <supervision-notification> subscription operation. + +After monitoring the subscription, the O-RU<sub>8</sub> should send monitoring notifications repeatedly. The O-DU<sub>8</sub> is responsible for sending the <supervision-watchdog-reset>RPC, and the O-RU<sub>8</sub> should reply with a timestamp for sending the next notification. + +When reset the “watchdog” timer, O-DU<sub>8</sub> (NETCONF Client) can set a new value for the “watchdog” timer, without receiving a <supervision-notification> from O-RU<sub>8</sub>. The new value will take effect immediately based on the contents of the <supervision-watchdog-reset> RPC, and the next <supervision-notification> should be no later than the timestamp provided in the RPC reply. + +The O-RU<sub>8</sub> will enter a “monitoring failure” state when the O-RU<sub>8</sub> fails to receive the <supervision-watchdog-reset>RPC after the “watchdog” timer times out. The O-RU<sub>8</sub> should close the “watchdog” timer immediately when all NETCONF sessions between O-RU<sub>8</sub> and O-DU<sub>8</sub> (NETCONF Client) with “sudo” privileges have been closed. + +##### Basic procedure: + +1 Figure 4-x shows the monitoring subscription and notification process for the NETCONF + 2 connection between O-RU<sub>8</sub> and O-DU<sub>8</sub>. + +![Sequence diagram showing the monitoring subscription and notification process between NETCONF Server/(O-RU) and NETCONF Client (O-DU).](d12ff49842cb24abfdb68d334e00cbcc_img.jpg) + +``` + +sequenceDiagram + participant Server as NETCONF Server/(O-RU) + participant Client as NETCONF Client (O-DU) + + Note over Client: 1 <rpc> +<create-subscription> +<stream>supervision-notification</stream> +</create-subscription> +</rpc> + Client->>Server: 2 <rpc-reply/> + + Note over Server: Default time of O-RU monitor timer (60s) + + Note over Server: opt [changing default timer on startup] + Client->>Server: 3 <rpc supervision-watchdog-reset> +</rpc> + Note over Server: Initially resetting monitor timer + Server->>Client: 4 <rpc-reply><next-update-at>date-time +</next-update-at></rpc-reply> + Note over Server: O-RU knows an initial value of the timer + + Note over Server: loop [monitoring loop] + Note over Server: Notifying time-out of timer + Server->>Client: 5 <notification> + Note over Client: R-DU working normally + Client->>Server: 6 <rpc supervision-watchdog-reset> +</rpc> + Note over Server: Resetting monitor timer + Server->>Client: 7 <rpc-reply><next-update-at>date-time +</next-update-at></rpc-reply> + Note over Server: O-DU working normally + + Note over Server: opt [monitor timer times out] + Note over Server: O-RU entering monitor failure state + +``` + +The diagram illustrates the monitoring subscription and notification process between the NETCONF Server/(O-RU) and the NETCONF Client (O-DU). The process is divided into several phases: + +- Subscription Phase:** The O-DU sends an RPC message to the O-RU to create a subscription for supervision notifications. The O-RU responds with an RPC reply. +- Initial Setup Phase:** The O-RU has a default monitor timer of 60s. The O-DU sends an RPC message to reset the supervision watchdog. The O-RU responds with an RPC reply containing the next update time. This phase is optional and occurs during startup. +- Monitoring Loop:** The O-RU monitors the timer. When the timer times out, the O-RU sends a notification to the O-DU. The O-DU responds with an RPC message to reset the supervision watchdog. The O-RU responds with an RPC reply containing the next update time. This loop is optional and occurs during normal operation. +- Failure State:** If the monitor timer times out, the O-RU enters a monitor failure state. This phase is optional. + +Sequence diagram showing the monitoring subscription and notification process between NETCONF Server/(O-RU) and NETCONF Client (O-DU). + +Figure Annex3- 1 + +1) The DU subscribes to the O-RU<sub>8</sub> for monitoring supervision-subscription by rpc: create- + +subscription + +- 2) After the RU receives the O-DU<sub>8</sub> monitoring subscription, rpc-reply replies with successful 200 or corresponding error code +- 3) The DU resets the “watchdog” timer by rpc: supervision-watchdog-reset +- 4) The RU updates reporting time by rpc: next-update-at +- 5) The RU reports supervision-notification to the O-DU<sub>8</sub> (the default time is 60s) +- 6) The DU resets the “watchdog” timer by rpc: supervision-watchdog-rese after the supervision-notification is received from the O-RU<sub>8</sub> +- 7) The RU updates reporting time by rpc: next-update-at + +##### Notes: + +- Steps 3-4 may be performed after O-RU<sub>8</sub> activation or Step 1. +- Steps 5-7 are repeated. +- The O-RU<sub>8</sub> will enter a “monitoring failure” state when the O-RU<sub>8</sub> fails to receive the supervision-watchdog-reset after the “watchdog” timer times out. + +#### A3.4.5.6 Disconnecting M-plane + +The O-DU<sub>8</sub> closes an existing NETCONF session by executing a RPC<close-session> command. The O-RU<sub>8</sub> responds to the command and closes an SSHv2 session. The O-RU<sub>8</sub> then restarts the call home procedure. + +#### A3.4.5.7 System Time Synchronization + +Since the clock in o-ran-operations.yang only synchronizes time zone, it cannot synchronize system time information, o-ran-system-time.yang is added to set the time of FHM<sub>8</sub> and O-RU<sub>8</sub>, which can be used for clock configuration of information such as log. + +Basic procedure: + +1. Time synchronization is mandatory when a NETCONF session is established. Time synchronization also needs to be triggered when the O-DU<sub>8</sub>’s system time changes. +2. In order to avoid the time difference between O-DU<sub>8</sub> and FHM<sub>8</sub> and O-RU<sub>8</sub> caused by transmission delay, O-DU<sub>8</sub> needs to determine time interval with RPC message when it receives RPC Reply, if the interval is more than 1 second, re-synchronization is required. + +## A3.5 Interface Management + +### A3.5.1 CPRI Interface Management + +1 Content of CPRI interface management mainly includes configuring CPRI basic attribute +2 parameters, as well as establishing CPRI U-plane data flow model, and transceiver parameter +3 acquisition and the like. + +###### 4 A3.5.1.1 YANG model + +5 Please refer to o-ran-interface-cpri.yang for CPRI basic attribute parameters configuration. + +6 Please refer to o-ran-processing-element-cpri.yang for CPRI U-plane data flow configuration. + +7 Please refer to o-ran-transceiver.yang for transceiver parameter acquisition. + +###### 8 A3.5.1.2 Dataflow model of CPRI U-plane + +9 Dataflow model of CPRI U-plane, o-ran-processing-elements-cpri.yang, which is formed based on +10 extension and definition of the existing O-RAN data flow model, o-ran-processing-elements.yang, +11 specifically includes: + +- 12 - creating a new type of transport session, and the new transport-session-type is CPRI interface +13 type, CPRI-INTERFACE; +- 14 - abstracting an IQ datablock portion in a CPRI frame structure into multiple CPRI dataflows, +15 cpri-flow, depending on the logical function carried; +- 16 - specifying a physical CPRI interface corresponding to each CPRI dataflow via interface-name +17 parameters; +- 18 - distinguishing different dataflows transported over the physical CPRI interface by different +19 string name parameters; and +- 20 - indicating finally that each device can support one or more physical CPRI interfaces, and each +21 physical CPRI interface can carry multiple CPRI dataflows. + +22 + +23 Each CPRI dataflow cpri-flow includes the following parameters: + +24 Iq-data-start-bit: identifying a start bit of IQ data for this cpri-flow; + +25 iq-data-end-bit: identifying an end bit of IQ data for this cpri-flow. + +26 Moreover, one additional parameter is required: + +27 compression-flag: for describing whether compression is performed on the IQ data. No if the bit +28 is false, and yes if the bit is true. + +29 If this parameter is set as false, the inband-compression-start-bit and inband-compression-end- +30 bit no longer take effect. + +inband-compression-start-bit: for describing a start bit of compression information for this cpri-flow. It is recommended to arrange from the initial position of the CPRI to avoid fragmentation. + +inband-compression-end-bit: for describing an end bit of the compression information of this cpri-flow. It is recommended to arrange from the initial position of the CPRI to avoid fragmentation. + +agc-start-bit: for describing an agc start bit of this cpri-flow. To avoid fragmentation, it is recommended that the AGC be arranged near the end position of the CPRI to avoid fragmentation. This parameter is ignored when AGC is not used. + +agc-end-bit: for describing an agc end bit of this cpri-flow. It is recommended that the AGC be arranged near the end position of the CPRI to avoid fragmentation. This parameter is ignored when AGC is not used. + +| | | 10.1376Gbps CPRI Basic frame (1/To) | | | | | | | | | | | | | | | | +|------|---|-------------------------------------|-----|-----|-----|-----|-----|------|------|------|------|------|------|------|------|------|----| +| | | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | +| 0 | A | 0 | 160 | 320 | 480 | 640 | 800 | 960 | 1120 | 1280 | 1440 | 1600 | 1760 | 1920 | 2080 | 2240 | | +| | B | 1 | 161 | 321 | 481 | 641 | 801 | 961 | 1121 | 1281 | 1441 | 1601 | 1761 | 1921 | 2081 | 2241 | | +| | C | 2 | 162 | 322 | 482 | 642 | 802 | 962 | 1122 | 1282 | 1442 | 1602 | 1762 | 1922 | 2082 | 2242 | | +| | D | 3 | 163 | 323 | 483 | 643 | 803 | 963 | 1123 | 1283 | 1443 | 1603 | 1763 | 1923 | 2083 | 2243 | | +| | E | 4 | 164 | 324 | 484 | 644 | 804 | 964 | 1124 | 1284 | 1444 | 1604 | 1764 | 1924 | 2084 | 2244 | | +| | F | 5 | 165 | 325 | 485 | 645 | 805 | 965 | 1125 | 1285 | 1445 | 1605 | 1765 | 1925 | 2085 | 2245 | | +| | G | 6 | 166 | 326 | 486 | 646 | 806 | 966 | 1126 | 1286 | 1446 | 1606 | 1766 | 1926 | 2086 | 2246 | | +| | H | 7 | 167 | 327 | 487 | 647 | 807 | 967 | 1127 | 1287 | 1447 | 1607 | 1767 | 1927 | 2087 | 2247 | | +| 1 | A | 8 | 168 | 328 | 488 | 648 | 808 | 968 | 1128 | 1288 | 1448 | 1608 | 1768 | 1928 | 2088 | 2248 | | +| | B | 9 | 169 | 329 | 489 | 649 | 809 | 969 | 1129 | 1289 | 1449 | 1609 | 1769 | 1929 | 2089 | 2249 | | +| | C | 10 | 170 | 330 | 490 | 650 | 810 | 970 | 1130 | 1290 | 1450 | 1610 | 1770 | 1930 | 2090 | 2250 | | +| | D | 11 | 171 | 331 | 491 | 651 | 811 | 971 | 1131 | 1291 | 1451 | 1611 | 1771 | 1931 | 2091 | 2251 | | +| | E | 12 | 172 | 332 | 492 | 652 | 812 | 972 | 1132 | 1292 | 1452 | 1612 | 1772 | 1932 | 2092 | 2252 | | +| | F | 13 | 173 | 333 | 493 | 653 | 813 | 973 | 1133 | 1293 | 1453 | 1613 | 1773 | 1933 | 2093 | 2253 | | +| | G | 14 | 174 | 334 | 494 | 654 | 814 | 974 | 1134 | 1294 | 1454 | 1614 | 1774 | 1934 | 2094 | 2254 | | +| | H | 15 | 175 | 335 | 495 | 655 | 815 | 975 | 1135 | 1295 | 1455 | 1615 | 1775 | 1935 | 2095 | 2255 | | +| 2-18 | | | | | | | | | | | | | | | | | | +| 19 | A | 152 | 312 | 472 | 632 | 792 | 952 | 1112 | 1272 | 1432 | 1592 | 1752 | 1912 | 2072 | 2232 | 2392 | | +| | B | 153 | 313 | 473 | 633 | 793 | 953 | 1113 | 1273 | 1433 | 1593 | 1753 | 1913 | 2073 | 2233 | 2393 | | +| | C | 154 | 314 | 474 | 634 | 794 | 954 | 1114 | 1274 | 1434 | 1594 | 1754 | 1914 | 2074 | 2234 | 2394 | | +| | D | 155 | 315 | 475 | 635 | 795 | 955 | 1115 | 1275 | 1435 | 1595 | 1755 | 1915 | 2075 | 2235 | 2395 | | +| | E | 156 | 316 | 476 | 636 | 796 | 956 | 1116 | 1276 | 1436 | 1596 | 1756 | 1916 | 2076 | 2236 | 2396 | | +| | F | 157 | 317 | 477 | 637 | 797 | 957 | 1117 | 1277 | 1437 | 1597 | 1757 | 1917 | 2077 | 2237 | 2397 | | +| | G | 158 | 318 | 478 | 638 | 798 | 958 | 1118 | 1278 | 1438 | 1598 | 1758 | 1918 | 2078 | 2238 | 2398 | | +| | H | 159 | 319 | 479 | 639 | 799 | 959 | 1119 | 1279 | 1439 | 1599 | 1759 | 1919 | 2079 | 2239 | 2399 | | + +Figure Annex3- 2 Bit position under 10.1376Gbps line rate + +The following example 1 is a configuration example with IQ data compressed, where cpri flow 0 corresponding to 100 MHz NR cell's antenna 0 and cpri flow 1 corresponding to 100 MHz NR cell's antenna 1: + + + +**Table Annex3- 9 Parameter configuration of two uncompressed cpri-flows under 10.1376Gbps line rate** + +| | compression-flag | iq-start-bit | iq-end-bit | inband-compression-start-bit | inband-compression-end-bit | agc-start-bit | agc-end-bit | +|-------------|------------------|--------------|------------|------------------------------|----------------------------|---------------|-------------| +| Cpri flow 0 | false | 0 | 1087 | 0 | 0 | 2392 | 2395 | +| Cpri flow 1 | false | 1088 | 2111 | 0 | 0 | 2396 | 2399 | + +#### A3.5.1.3 Transceiver parameter acquisition + +The eCPRI transceiver parameter acquisition defined by O-RAN specification can be used in the CPRI transceiver parameter acquisition. + +O-ran-interface-cpri.yang and o-ran-transceiver.yang are associated via a port-number under cpri-interface, to represent corresponding receiver parameters on the port-number interface. + +##### A3.5.1.3.1 Procedure + +##### A3.5.1.3.2 Transceiver Procedure + +###### Pre-condition: + +M-plane connection between the NETCONF client and the O-RU<sub>8</sub> is established. + +###### Post-condition: + +At the end of this procedure, the NETCONF client obtains the O-RU<sub>8</sub> transceiver module information. + +###### Basic procedure: + +1) During a start-up phase, the O-RU<sub>8</sub> detects the transceiver module and stores data information from a transceiver module in a file; + +2) The NETCONF client obtains the file according to an upload process of netconf-yang file. + +3) Exception: + +- If the transceiver module is inserted during the file upload process, then the process will provide a file with previous content, or fails. +- If the FHM<sub>8</sub> is unable to extract data from the transceiver module, or the file does not + +exist, then the FHM<sub>8</sub> will not create file or delete the file previously created (note: the file upload will fail because the upload process requests a file that does not exist). + +##### A3.5.1.3.3 M-plane configuration procedure of CPRI interface + +###### Pre-condition: + +M-plane connection between the NETCONF client and the O-RU<sub>8</sub> is established. + +###### Post-condition: + +At the end of this procedure, the O-RU<sub>8</sub> CPRI U-plane configuration is completed. + +###### Basic procedure: + +CPRI link U-plane information is configured according to newly defined o-ran-processing-element-cpri model. The configuration information includes whether to compress IQ data, start bit position of IQ data, end bit position of IQ data, start bit position of compression information, end bit position of compression information, AGC start bit position, AGC end bit position and the like. After completing IQ configuration process for the CPRI interface, CPRI mapping relationship on a southbound CPRI interface is determined. Different IQ configurations are required on the CPRI interfaces for different cell bandwidth and antenna configurations. + +## A3.6 Software Management + +The Software Management function provides a set of operations allowing the desired software build to be downloaded, installed and activated at the O-RU<sub>8</sub>. Successful software activation operation does not mean an O-RU<sub>8</sub> is running the just activated software build. An RPC<reset> operation is required to trigger the O-RU<sub>8</sub> to take the activated software build into operational use. A single software build may be considered as set of internally consistent files compliant within such a build. Software build is a subject of versioning and maintenance and as such cannot be broken. Replacement of files within a build is prohibited, as this will cause software version incompatibility. The use of compression and ciphering for the content of the software build is left to vendor implementation. The only file which shall never be ciphered is the manifest.xml file. It is also Vendor's responsibility to handle software build/ package/ file integrity check. The O-RU<sub>8</sub> provides a set of so called "software slot" or "slot". Each slot provides an independent storage location for a single software build. The number of slots offered by O-RU<sub>8</sub> depends on the devices' capabilities. At least two writable slots shall be available at the O-RU<sub>8</sub> for failsafe update operation. Presence of read only software slot is optional. The software slots are resources provided by the O-RU<sub>8</sub> and as such are not the subject of creation and deletion. The size of individual software slot is fixed and determined by the O-RU<sub>8</sub>'s vendor and sufficient to accommodate the full software build. + +### A3.6.1 Specific Conventions + +#### A3.6.1.1 Comparison of specification requirements + +A comparison of differences between this chapter and the O-RAN M-plane Specification [1] is shown in the table below: + +**Table Annex3- 10 Comparison of differences with software management related specification** + +| | specification of O-RAN M-plane | Requirements of the present specification | +|------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------| +| software slot | at least two writable software slots are supported, and read only software slot is optionally supported | the same as the O-RAN specification | +| sFTP transport certification | password-based O-RU <sub>s</sub> certification and public key(DSA/RSA) list-based sFTP server certification; certificate based O-RU <sub>s</sub> and sFTP server certification | password-based O-RU <sub>s</sub> certification and public key(DSA/RSA) list-based sFTP server certification | + +#### A3.6.1.2 YANG model + +Please refer to o-ran-software-management.yang model for relative detailed definitions of NETCONF. + +#### A3.6.1.3 Conception and terms + +Translation of basic concepts in this chapter: + +**Package--software package:** a package contains one or more builds. + +**Build--software compilation package:** a build can be considered as set of internally consistent files, and a specific hardware type corresponds to the corresponding build. + +**Software-slot--software storage area:** Each software-slot is an independent storage space, and each software build is stored in a different software-slot. The number of software-slots offered by O-RU<sub>s</sub> depends on the device's storage capacity. + +##### Files -- software files. + +### A3.6.2 Package + +The package is delivered by the O-RU<sub>s</sub> vendor. + +Each package includes: + +- manifest.xml +- software files to be installed on O-RU<sub>s</sub> + +The name of package should follow the following format: + +“<Vendor Code><Vendor Specific Filed>[#NUMBER].EXT” + +Where: + +- *Vendor Code* is a mandatory part which has two capital characters, +- *Vendor Specific Field* is a mandatory part and consists of characters used to define a filename. The value must not include character “\_” (underscore) or “#” (hash). The value can be defined per vendor for the human readable information. Version information is necessary in the Vendor Specific Field which defines load version, +- *NUMBER* is optional and used when the original file is split into smaller pieces – number after “#” indicates the number of a piece. Numbering starts from 1 and must be continuous; +- *EXT* is a mandatory part which defines the extension of filename. A vendor provides one or more software packages. Each software package shall be compressed by zip. + +Note: the name of package needs a <Vendor Code> prefix to avoid issue if two vendors provide files with same name. + +Note: the NETCONF client shall support ZIP functionality to enable support of compressed files types. + +Note: the operator needs to manage and control which O-RU<sub>s</sub> files will be stored and used in the file server, e.g., based on O-RU<sub>s</sub> files provided by O-RU<sub>s</sub> vendors and network configurations. The operator needs to make sure that only the expected version of O-RU<sub>s</sub> files will be transferred from the file server to the O-RU<sub>s</sub>. Different versions of files for O-RU<sub>s</sub> with the same vendor and same product code should be avoided. + +The content of the manifest.xml file allows to maintain software update process correctly in terms of compatibility between O-RU<sub>s</sub> hardware and software build to be downloaded. The content of the Manifest file prohibits the O-RU<sub>s</sub> from installing software builds designed for device based on different hardware. The format of the manifest.xml file is: + +``` +<xml> +<manifest version="1.0"> /// +@version describes version of file format (not the content) +``` + +``` + +<products> + +<product vendor="XX" code="0818820\.x11" +name="RUXX.x11" build-Id="1"/> + +<product vendor="XX" code="0818820\.x12" +name="RUXX.x12" build-Id="1"/> + +<product vendor="XX" code="0818818\..." name="RUYY" build-Id="2"/> + +/// @vendor is as reported by +O-RU8 + +/// @code is a regular +expression that is checked against productCode reported by O-RU8 + +/// @name is optional and +used for human reading – MUST NOT be used for other purposes! + +/// @buildId is value of +build@id (see below) + +</products> + +<builds> + +<build id="1" bldName="xyz" +bldVersion="1.0"> + +/// @id is index of available +builds. + +/// @bldName and @bldVersion +are used in YANG (build-name, build-version) + +<file fileName="xxxx" fileVersion="1.0" +path="full-file_name-with-path-relative-to-package-root-folder" checksum="FAA898"/> + +<file fileName="yyyy" fileVersion="2.0" +path="full-file_name-with-path-relative-to-package-root-folder" +checksum="AEE00C"/> + +/// @fileName and +@fileVersion are used in YANG (name, version) + +/// @path is full path (with +name and extension) of a physical file, relative to +package +root folder,used in YANG (local-path) + +/// @checksum is used to + +``` + +``` + +check file integrity on O-RU8 side + +</build> + +<build id="2" bldName="xyz" bldVersion="1.0"> + + <file fileName="xxxx" fileVersion="1.0" + + path="full-file_name-with-path-relative-to-package-root-folder" + + checksum="FAA898"/> + + <file fileName="yyyy" fileVersion="2.0" + + path="full-file_name-with-path-relative-to-package-root-folder" checksum="AEE00C"/> + + <file fileName="zzzz" fileVersion="1.5" + + path="full-file_name-with-path-relative-to-package-root-folder" checksum="ABCDEF"/> + +</build> + +</builds> + +</manifest> + +</xml> + +``` + +Note: Keywords in manifest.xml example are in bold, the keywords must be strictly followed considering of cross-vendor cases. + +Note: Correspondency between content of manifest.xml tags and content of o-ran-software-management.yang is: + +- XML tag “product vendor” corresponds to content of leaf “vendor-code”, +- XML tag “code” corresponds to content of leaf “product-code”, +- XML tag “build-Id” corresponds to content of leaf “build-id”, +- XML tag “bldName” corresponds to content of leaf “build-name”, +- XML tag “bldVersion” corresponds to content of leaf “build-version”, +- XML tag “fileName” corresponds to content of leaf “name” in list “files”, +- XML tag “fileVersion” corresponds to content of leaf “version” in list “files”. + +### A3.6.3 Software Inventory Query Procedure + +#### **Pre-condition:** + +When M-plane NETCONF session is established, this procedure can be started. + +#### **Post-condition:** + +1 NETCONF client successfully collected the software inventory information from NETCONF server +2 at the end of this procedure. + +###### 3 **Basic procedure:** + +4 The figure below shows an example of the software inventory query procedure. + +![Sequence diagram showing the software inventory query procedure between a NETCONF server and a NETCONF client. The client sends an rpc get operation to query software-slot information, and the server responds with an rpc-reply containing the data.](9b80aab779c011764acbd8d1da7ffa36_img.jpg) + +Software Management \_Software Inventory Query + +``` + +sequenceDiagram + participant Server as NETCONF server + participant Client as NETCONF client + Note over Client: [1] <rpc> +<get> +<software-slot> .. </software-slot> +</get> +</rpc> + Client->>Server: + Note over Server: <rpc-reply> +<data> +[2] <software-slot>....</software-slot> +</data> +</rpc-reply> + Server-->>Client: + +``` + +Sequence diagram showing the software inventory query procedure between a NETCONF server and a NETCONF client. The client sends an rpc get operation to query software-slot information, and the server responds with an rpc-reply containing the data. + +Figure Annex3- 5 Example of software inventory query procedure + +- 1) NETCONF client sends rpc get operation to NETCONF server to query software-slot. +- 2) The NETCONF server sends rpc-reply to the NETCONF client to return detailed information about the software-slot. + +###### 11 **Notes:** + +- Please refer too-ran-software-management.yang model for detailed information about software-slot. +- If a slot contains a file with integrity NOK, the O-RU<sub>s</sub> shall mark the whole slot with status as INVALID. +- The content of a software-slot is fully under O-RU<sub>s</sub>'s management - including removal of the content occupying the slot (in case the slot is subject of software update procedure), control of file system consistency and so on. The slot content shall not be removed until there is a need for new software to be installed. +- The empty slot parameters shall be set by NETCONF server as follows: +name: up to vendor, not empty; + +1 status: INVALID; +2 active: False; +3 running: False; +4 access: READ\_WRITE; +5 product-code: up to vendor; +6 vendor code: up to vendor; +7 build-name: null; +8 build-version: null; +9 files: empty. + +###### 10 A3.6.4 Software Download Procedure + +###### 11 **Pre-condition:** + +12 When M-plane connection is established, software download procedure can be started. + +###### 13 **Post-condition:** + +14 O-RU<sub>s</sub> downloads all files specified and successfully stores the downloaded files in the O-RU<sub>s</sub>'s +15 file system at the end of this procedure. + +###### 16 **Basic procedure:** + +17 The figure below shows an example of the software download procedure. + +![Sequence diagram showing a NETCONF Client sending a software inventory query to a NETCONF Server. The client sends an <rpc> <get> [1] <software-slot> .. </software-slot> </get> </rpc> message. The server responds with an <rpc-reply> <data> [2] <software-slot>....</software-slot> </data> </rpc-reply> message.](93dcc010dc08253f9f81a7ab476df6fe_img.jpg) + +Software Management \_Software Inventory Query + +``` + +sequenceDiagram + participant Client as NETCONF Client + participant Server as NETCONF Server + Client->>Server: <rpc> <get> [1] <software-slot> .. </software-slot> </get> </rpc> + Server-->>Client: <rpc-reply> <data> [2] <software-slot>....</software-slot> </data> </rpc-reply> + +``` + +Sequence diagram showing a NETCONF Client sending a software inventory query to a NETCONF Server. The client sends an [1] .. message. The server responds with an [2] .... message. + +Figure Annex3- 6 Example of software download procedure + +- 1) NETCONF client send software-download operation to NETCONF server. +- 2) The NETCONF server replies to the NETCONF client with software-download state. +- 3) O-RU<sub>8</sub> transports software files by using sFTP protocol. +- 4) The NETCONF server sends a download-event notification to the NETCONF client. +- 5) If there are multiple software files to be downloaded, the above will be repeated until all of files have been downloaded. + +##### **Notes:** + +- The NETCONF client determines the software file to be downloaded according to hardware information of the O-RU<sub>8</sub> (vendor number, product number, product name, etc.) and the manifest.xml file of the software package. +- The software download sFTP transmission supports the following types of authentication: password-based O-RU<sub>8</sub> authentication and public key (DSA/RSA) list-based sFTP server authentication. + +### A3.6.5 Software Installation Procedure + +#### **Pre-conditions:** + +- M-plane NETCONF session established. +- At least one software slot with a status of active::False and running::False in O-RU<sub>8</sub>. +- Software Download has been completed successfully and files are available in O-RU<sub>8</sub>. + +#### **Post-condition:** + +- O-RU<sub>8</sub> software is installed in the specified target software-slot. + +#### Basic procedure: + +The software installation procedure is shown in FIG. 32. + +![Sequence diagram showing the software installation procedure between a NETCONF server and a NETCONF client. The diagram includes three messages: 1. A <rpc> message with <software-install> and <slot-name>..</slot-name> from client to server. 2. A <rpc-reply> message with <software-install> and <status>..</status> from server to client. 3. A <notification> message with <install-event> and <status>...</status> from server to client.](79180f44ef0821b5dff7ecbd6f317b89_img.jpg) + +Software Management\_Software Installation + +``` + +sequenceDiagram + participant Client as NETCONF client + participant Server as NETCONF server + Note over Client: [1] <rpc> + Note over Client: <software-install> + Note over Client: <slot-name>..</slot-name> + Client->>Server: + Note over Server: [2] <rpc-reply> + Note over Server: <software-install> + Note over Server: <status>..</status> + Server->>Client: + Note over Server: [3] <notification> + Note over Server: <install-event> + Note over Server: <status>...</status> + Server->>Client: + +``` + +Sequence diagram showing the software installation procedure between a NETCONF server and a NETCONF client. The diagram includes three messages: 1. A message with and .. from client to server. 2. A message with and .. from server to client. 3. A message with and ... from server to client. + +Figure Annex3- 7 + +NETCONF **software-install** **rpc** is used to install the previously downloaded software (all files provided in the package) to the specified target **software-slot** on O-RU<sub>8</sub>. This slot must have status active::False and running::False. + +The O-RU<sub>8</sub> shall send an immediate rpc-reply message with one of following statuses: + +- **STARTED**: software install operation has been started; +- **FAILED**: software install operation could not be proceeded, reason for failure in error-message. + +When O-RU<sub>8</sub> completes the software install or software install procedure fails, the O-RU<sub>8</sub> will send NETCONF **install-event** notification with one of the following statuses: + +- COMPLETED; +- FILE\_ERROR: operation on the file resulted in in error, disk failure, not enough disk space, incompatible file format; +- INTEGRITY\_ERROR: file is corrupted; +- APPLICATION\_ERROR: operation failed due to internal reason. + +When the software install commences, the O-RU<sub>8</sub> shall set the slot status to INVALID. After the install procedure finishes, the O-RU<sub>8</sub> shall change the slot status to its appropriate status. This operation avoids reporting of inaccurate status when the install procedure is in operation or when it is interrupted (e.g., by spurious reset operation). + +### A3.6.6 Software Activation Procedure + +#### **Precondition:** + +- M-Plane NETCONF session established. +- Software slot to be activated has status VALID. + +#### **Post-conditions:** + +- O-RU<sub>8</sub> software activates to the version of software slot. + +#### **Basic procedure:** + +The software activation procedure is shown in FIG. 33. + +![Sequence diagram showing the software activation process between a NETCONF Server and a NETCONF Client. The process includes an initial activation request, a status reply, a notification, a server reboot, and a final reset request and reply.](3f79c6673e8f64183c5cdcca45f14109_img.jpg) + +Software Management\_Software Activation + +``` + +sequenceDiagram + participant Server as NETCONF Server + participant Client as NETCONF Client + + Note over Server: [1] <rpc> +<software-activate> +<slot-name>..</slot-name> +</software-activate> +</rpc> + Client->>Server: + Note over Server: [2] <rpc-reply> +<software-activate> +<status>..</status> +</software-activate> +</rpc-reply> + Server->>Client: + Note over Server: [3] <notification> +<activation-event> +<status>...</status/> +</activation-event> +</notification> + Server->>Client: + Note over Server, Client: Reboot server + Note over Server: [4] <rpc> +</reset> +</rpc> + Client->>Server: + Note over Server: [5] <rpc-reply> +</reset> +</rpc-reply> + Server->>Client: + +``` + +Sequence diagram showing the software activation process between a NETCONF Server and a NETCONF Client. The process includes an initial activation request, a status reply, a notification, a server reboot, and a final reset request and reply. + +Figure Annex3- 8 + +NETCONF **software-activate** rpc is used to activate the software. The name of the software-slot is specified in the activate request. + +The O-RU<sub>s</sub> shall send an immediate rpc-reply message with one of following statuses: + +- **STARTED**: software activation operation has been started; +- **FAILED**: software activation operation could not be proceeded, reason for failure in **error-message**. + +When the activation is completed, the O-RU<sub>8</sub> shall send the NETCONF **activation-event** notification with the status of activation. The following status is returned in the NETCONF **activation-event** notifications: + +- **COMPLETED**: activation procedure is successfully completed. O-RU<sub>8</sub> must be restarted via NETCONF reset rpc for the new software activated. +- **APPLICATION\_ERROR**: operation fails due to internal reason. + +Only one software slot can be active at one time. Thus, **software-activate** command will set active::True to the slot that was provided in the rpc and automatically set active::False to the previously activated slot. + +NETCONF **reset** rpc shall be sent to O-RU<sub>8</sub> to activate the version of the software slot. O-RU<sub>8</sub> restarts and performs startup procedure as described in Chapter 3 as regular startup with new software version running. + +### A3.6.7 Software Update Procedure + +Basic Software Update Procedure is as following: + +![Sequence diagram showing the basic procedure of software update between NETCONF Server and NETCONF Client. The process includes reading software inventory, downloading software files, installing software, and activating software.](489596f747eaa98cebf35762bfc05306_img.jpg) + +Software Managemetnt\_Software Update Examples + +``` + +sequenceDiagram + participant Server as NETCONF Server + participant Client as NETCONF Client + Client->>Server: ref Reading software inventory procedure + activate Server + Server->>Client: loop [Every file in software package] + activate Client + Client->>Server: ref Software download procedure + activate Server + Server->>Client: ref Software installation procedure + activate Client + Client->>Server: ref Software activation procedure + activate Server + Server->>Client: + deactivate Server + Client->>Server: + deactivate Client + +``` + +The diagram illustrates the basic procedure of software update between a NETCONF Server and a NETCONF Client. The process is as follows: + +- The NETCONF Client sends a **ref** message to the NETCONF Server for the **Reading software inventory procedure**. +- The NETCONF Server sends a **loop** message to the NETCONF Client, with the note **[Every file in software package]**. +- The NETCONF Client sends a **ref** message to the NETCONF Server for the **Software download procedure**. +- The NETCONF Server sends a **ref** message to the NETCONF Client for the **Software installation procedure**. +- The NETCONF Client sends a **ref** message to the NETCONF Server for the **Software activation procedure**. +- The NETCONF Server sends a message back to the NETCONF Client, and the NETCONF Client sends a message back to the NETCONF Server, indicating the end of the process. + +Sequence diagram showing the basic procedure of software update between NETCONF Server and NETCONF Client. The process includes reading software inventory, downloading software files, installing software, and activating software. + +**Figure Annex3- 9 Basic procedure of software update** + +1. NETCONF client performs a software inventory operation and determines that a new software + +- package is available and can be installed on the O-RU<sub>8</sub>. +2. NETCONF client using the **software-download** rpc requests the O-RU<sub>8</sub> to download a software package (if the software package contains several files, steps 2-4 need to be performed repeatedly until all files have been downloaded). +3. O-RU<sub>8</sub> sends rpc response that download was started. +4. O-RU<sub>8</sub> finishes downloading the file(s) and reports this by sending the **download-event** notification. +5. NETCONF client requests installation of the software using **software-install** rpc, and provides the slot name where the software needs to be installed along with a list of filenames to be installed (if the software package contains only one file, the list will contain only one entry). +6. O-RU<sub>8</sub> sends rpc response that installation was started. +7. O-RU<sub>8</sub> sets installation slot status to INVALID. +8. O-RU<sub>8</sub> installs the software and after successful installation (with checksum control) changes status of the slot to VALID. +9. O-RU<sub>8</sub> notifies the NETCONF client that the installation is finished using **install-event** notification. +10. NETCONF client requests the O-RU<sub>8</sub> to activate the newly installed software using the **software-activate** rpc. +11. O-RU<sub>8</sub> sends rpc response that activation was started. +12. For requested slot, O-RU<sub>8</sub> changes active::True and at the same time sets active::False on previously active slot. +13. O-RU<sub>8</sub> notifies NETCONF client about activation finished using the **activation-event** notification. +14. NETCONF client restarts the O-RU<sub>8</sub> forcing it to use the newly installed and activated software. The O-RU<sub>8</sub> restarts as regular startup with new software version running. + +### A3.6.8 Factory Reset + +O-RU<sub>8</sub> can be reset to the factory default software by activating the software-slot containing the factory default software and initiating NETCONF reset rpc. O-RU<sub>8</sub> may clear persistent memory data during factory reset as vendor implementation option. This function is optional. + +## A3.7 Fault Management + +### A3.7.1 Specific Conventions + +This chapter refers to Chapter 8 and Appendix A of the O-RAN M Plane Specification [3]. Because of the general nature of alarm management, this chapter basically follows the original specification in terms of functions, procedures and options. + +In order to improve the readability of the Chinese version, the content of the original text has been modified and the fault levels described in Appendix A have been moved to Section 4.5.2.6. In + +1 addition, in order to maintain the consistency of the revised text, some notes have been added to +2 help reader to understand. + +###### 3 A3.7.2 Overview of Fault + +###### 4 A3.7.2.1 Overall situation + +5 The O-RAN fault management mechanism is based on O-RAN NETCONF management +6 framework and the specification covers alarm management of O-RU<sub>s</sub>. The mechanism includes two +7 types of operation body, an alarm server and an alarm client which are simplified as Server and +8 Client below in this section. + +###### 9 **Operation body:** + +10 **1) Server:** NETCONF server, as defined in Basic Conventions of Chapter 1. + +11 **2) Client:** NETCONF client, as defined in Basic Conventions of Chapter 1. + +12 The server is the main body for maintaining fault information. It maintains an “active-alarm-list” +13 (including Critical, Major and Minor levels, and excluding WARNING level) and sends “alarm +14 notification” to the subscribing body when the alarms change. The alarm notification contains only +15 changed portion of alarms, not all alarms. + +##### 16 **Main operation:** + +17 The main functions provided by the server are “Reading active-alarm-list”, “Notifying”, +18 “Subscribing” and “cancel subscription”. + +19 **Reading active-alarm-list:** the client can use this feature to get all current activity alarm +20 information. + +21 **Subscribe/cancel subscription:** the client initiates to the server with subscription notification or +22 cancel subscription notification. + +23 **Notification:** the server sends an alarm notification to the client when the alarm information +24 changes. + +##### 25 A3.7.2.2 Key definition and Description + +###### 26 A3.7.2.3 Granularity and identification of alarm message + +27 The alarm messages are presented at the level of a single alarm. + +Each alarm message is identified by the following three tuples: fault-id, fault-source and fault-severity. If the three tuples are the same, it identifies the same alarm; if there is any different tuple, it represents a different alarm. + +#### A3.7.2.4 Fault-id + +Fault numbers are divided into two categories: “public” and “manufacturer defined”. Appendix A defines common fault numbers and reserves more numbers for future expansion (Note: Common fault numbers range from 0 to 999). Vendor defined fault number range is [1000 ... 65535]. + +#### A3.7.2.5 Fault-source + +Alarm notifications reported by NETCONF Server contain element “fault-source” which indicates the origin of an alarm. In general values of “fault-source” are based on names defined as YANG leafs: + +##### - Source (in O-RU<sub>s</sub>, Examples: fan, module, PA, port) + +indicates that fault sources within the O-RU<sub>s</sub>. Value of “fault-source” is set as name of YANG leafs. + +\*Note: In case the NETCONF Server reports an “unknown” fault-source, the NETCONF Client can discard the alarm notification. + +##### - Source (outside O-RU<sub>s</sub>) + +Value of fault-source may be empty or may identify the most likely external candidate; for example, antenna. + +#### A3.7.2.6 Fault-severity + +Fault levels are defined as three types: critical, major, and minor, without warning, with the following meaning: + +Severe: the scope specified in the alarm is no longer available. + +Significant: the scope specified in the alarm is available but performance is degraded. + +Normal: there are alarms, but no performance is impacted. + +#### A3.7.2.7 Failure source and affected object + +Both are concepts of functional body in the context of alarm. The former emphasizes the “source” and the latter (affected-objects) emphasizes the affected object. For example, if failure source is a + +quartz crystal oscillator (OCXO), the affected objects may be many of the components defined in the O-RU<sub>8</sub>. + +The English version of the O-RAN specification emphasizes that when the failure source is in the O-RU<sub>8</sub>, the failure source should not be placed in the affected-objects. + +### A3.7.3 Reading Alarm Procedure + +The server is responsible for maintaining an active-alarm-list. This list does not contain any “warning” level information. When an alarm is detected, it is added into the list; when the cause of the alarm disappears, the alarm will be cleared, i.e., removed from the active-alarm list. Further, if this alarm source is the fault-source of an existing alarm, then all associated alarms are removed from the current fault list. + +Operation mode: + +The client operates “get” to read the active alarms list by NETCONF rpc, see FIG. 11-1 for procedure. + +Reading NETCONF rpc operation is an operation for the full table, it has a strong initialization nature, and it is mainly used in an establishment phase of the alarm management relationship to get the initial situation of the alarms. During the operation, this mode can also be used periodically in low-frequency, to realize periodical synchronization of full tables of alarm management information for both parties, in case of long time step out of the alarm information due to unexpected situation. + +For specific use of this method, this specification does not stipulate. + +![Sequence diagram showing the procedure of reading active alarm list between NETCONF Server/(O-RU) and NETCONF Client.](9cd3f945f7c87fad96ed812cbe810faa_img.jpg) + +``` + +sequenceDiagram + participant Server as NETCONF Server/(O-RU) + participant Client as NETCONF Client + Note over Server: NETCONF session established + Note over Server: active-alarm-list Request + Server->>Client: [1] <rpc>\<get>\active-alarm-list<get>\</rpc> + Note over Client: active-alarm-list Response + Client-->>Server: [2] <rpc-reply>\<data>active-alarm-list<data>\</rpc> + +``` + +Sequence diagram showing the procedure of reading active alarm list between NETCONF Server/(O-RU) and NETCONF Client. + +Figure Annex3- 10 Procedure of reading active alarm list + +In the O-RAN alarm management system, NETCONF server provides alarm initial information in the form of full table by “obtaining active-alarm-list” operation, which is the “static” part. The client subscribes alarm notifications (with filtering conditions) to the server, the server (based on conditional filtering) finds the alarm changes and updates the local active-alarm-list, and then notifies the client of the alarm changes in form of alarm notifications. A complete alarm notification system is formed by a static part and a dynamic part. + +The alarm notification subscription is initiated by the client and responded by the server, which includes two cases, with or without filtering conditions. Definitions of message formats of subscription with and without filtering conditions are given in chapter 4.5.3.2 and chapter 4.5.3.3, respectively. In high-level view, the NETCONF alarm subscription has a brief process shown in FIG. 19. + +#### A3.7.3.1 Subscription message format + +The NETCONF Client can “subscribe” to Fault Management Element by sending “create-subscription”, RFC5277 [21], to NETCONF Server. + +RFC5277 allows “create-subscription” below: + +``` +<netconf:rpc netconf:message-id=“101” +``` + +``` +xmlns:netconf=“urn:ietf:params:xml:ns:netconf:base:1.0”> +``` + +``` + +1 <create-subscription +2 xmlns="urn:ietf:params:xml:ns:netconf:notification:1.0"> +3 <filter netconf:type="subtree"> +4 <event xmlns="http://example.com/event/1.0"> +5 <eventClass>fault</eventClass> +6 <severity>critical</severity> +7 </event> +8 <event xmlns="http://example.com/event/1.0"> +9 <eventClass>fault</eventClass> +10 <severity>major</severity> +11 </event> +12 <event xmlns="http://example.com/event/1.0"> +13 <eventClass>fault</eventClass> +14 <severity>minor</severity> +15 </event> +16 </filter> +17 </create-subscription> +18 </netconf:rpc> + +``` + +Note: the NETCONF Client can disable/enable alarm sending only for all the alarms with same severity, not for a single alarm. + +![Sequence diagram showing the procedure of alarm subscription between a NETCONF Server/(O-RU) and a NETCONF Client. The client sends a <rpc><create-subscription> message with an alarm-notif filter. The server responds with an <rpc-reply> message. A note indicates that the server retrieves active alarms corresponding to the filter settings.](3b15cab8f4124ded2ba0b1da7ae45ed0_img.jpg) + +``` + +sequenceDiagram + participant Server as NETCONF Server/(O-RU) + participant Client as NETCONF Client + Client->>Server: [1] <rpc><create-subscription> +<alarm-notif/> +<filter netconf.type=subtree> +</alarm-notif> +</create-subscription></rpc> + Server-->>Client: [2] <rpc-reply> + Note over Server: Retrieves active alarms +corresponding to the +filter settings + +``` + +Sequence diagram showing the procedure of alarm subscription between a NETCONF Server/(O-RU) and a NETCONF Client. The client sends a message with an alarm-notif filter. The server responds with an message. A note indicates that the server retrieves active alarms corresponding to the filter settings. + +Figure Annex3- 11 Procedure of alarm subscription + +#### A3.7.3.2 Case 1: Subscription request with filter conditions + +NETCONF client subscribes “alarm-notif” filtering fault-severity: CRITICAL, MAJOR and MINOR, and “measurement-result-stats” filtering “transceiver-stats” and “rx-window-stats” which measurement-object is RX\_ON\_TIME only: + +``` + +<rpc xmlns:netconf="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="101"> + <create-subscription + xmlns="urn:ietf:params:xml:ns:netconf:notification:1.0"> + <filter netconf:type="subtree"> + <alarm-notif xmlns="urn:o-ran:fm:1.0"> + <fault-severity>CRITICAL</fault-severity> + </alarm-notif> + <alarm-notif xmlns="urn:o-ran:fm:1.0"> + <fault-severity>MAJOR</fault-severity> + </alarm-notif> + <alarm-notif xmlns="urn:o-ran:fm:1.0"> + <fault-severity>MINOR</fault-severity> + </alarm-notif> + </filter> + </create-subscription> +</rpc> + +``` + +``` + + </alarm-notif> + <measurement-result-stats xmlns="urn:o-ran:performance-management:1.0"> + <transceiver-stats/> + </measurement-result-stats> + <measurement-result-stats xmlns="urn:o-ran:performance-management:1.0"> + <rx-window-stats> + <measurement-object>RX_ON_TIME</measurement-object> + </rx-window-stats> + </measurement-result-stats> + </filter> + </create-subscription> +</rpc> + +``` + +#### A3.7.3.3 Case 2: Subscription request without filter conditions + +NETCONF client subscribes default event stream NETCONF to receive all notifications defined in O-RAN YANG modules: + +``` + +<rpc xmlns:netconf="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="101"> + <create-subscription xmlns="urn:ietf:params:xml:ns:netconf:notification:1.0"> + <stream>NETCONF</stream> + </create-subscription> +</rpc> + +``` + +### A3.7.4 Procedure of reporting alarm + +After the NETCONF client subscribes to an alarm notification, the NETCONF server is responsible for sending alarm notifications (alarm-notif) to the client, which involves two cases: + +- 1) a new alarm is detected (note: this may be an alarm the same as the existing alarm with different fault source); +- 2) an alarm is removed from the active alarm list. + +1 Alarm removed from the active alarm list caused by fault source detection is considered as alarm +2 clearing, which will result in an alarm notification being sent to the NETCONF client. This is +3 applicable for alarms that are explicitly associated with detected fault source. This is to avoid step +4 loss of information between NETCONF clients that could result from a particular client detecting +5 corresponding cell. + +6 The NETCONF server only reports new alarms or alarms that have just disappeared in the alarm +7 notification, not all active alarms every time. + +![Diagram illustrating the procedure of an alarm notification. A NETCONF Server/(O-RU) box at the top left sends a notification to a NETCONF Client box at the top right. A yellow callout box from the server contains the text: 'O-RU detects a change of state in one of the alarms in the active-alarm-list corresponding to the filter settings established in the subscription'. The notification message is shown as a dashed arrow pointing from the server to the client, containing the XML snippet: '<notification> [1] <alarm-notif>..</alarm-notif> </notification>'. Below the main flow, there are two additional boxes: 'NETCONF Server/(O-RU)' and 'NETCONF Client', connected by dashed lines, representing the underlying connection.](c9ac5e0ed975c1f457839ba69e527b9c_img.jpg) + +Diagram illustrating the procedure of an alarm notification. A NETCONF Server/(O-RU) box at the top left sends a notification to a NETCONF Client box at the top right. A yellow callout box from the server contains the text: 'O-RU detects a change of state in one of the alarms in the active-alarm-list corresponding to the filter settings established in the subscription'. The notification message is shown as a dashed arrow pointing from the server to the client, containing the XML snippet: ' [1] .. '. Below the main flow, there are two additional boxes: 'NETCONF Server/(O-RU)' and 'NETCONF Client', connected by dashed lines, representing the underlying connection. + +8 + +9 + +Figure Annex3- 12 procedure of an alarm notification + +10 + +11 In short: + +12 Alarms are reported in form of alarm notifications. According to filtering conditions, the server +13 sends alarm notifications to the subscriber (client) when an alarm change required to be notified is +14 detected. The notifications are at the level of a single alarm, not all alarm information is sent. + +15 **The alarm updates** (the alarm information identification is a ternary group: fault number, fault +16 source, and fault level). When the alarm level needs to be updated, the server sends a new alarm +17 notification first, and then sends the old alarm clearing notification. Example: + +18 When an alarm of fault ID with the same fault source is reported in different fault levels, the alarm +19 level will be upgraded or downgraded, specifically: NETCONF server reports an alarm of “the +20 same fault number, the same fault source, a new fault level, and the is-cleared field of “FALSE”, +21 and clear the previous alarm by reporting “fault ID, fault source, the original fault level, and is- +22 cleared of “TRUE” (note: alarm update is achieved by adding new alarms first and then removing +23 the old alarms). + +### A3.7.5 Procedure of terminating an alarm subscription + +If the subscription is to be terminated, the client sends “<close-session>” operation in a subscription session. See FIG. 11-4 for a flowchart. + +![Sequence diagram showing the procedure of terminating an alarm subscription between a NETCONF Server/(O-RU) and a NETCONF Client.](bd4a6d5c9ffe6ab2d8990a07e479b8d8_img.jpg) + +``` + +sequenceDiagram + participant Server as NETCONF Server/(O-RU) + participant Client as NETCONF Client + Note over Server: [1] subscribed alarm-notif to be closed + Client->>Server: <rpc> +<close-session> +</close-session> +</rpc> + Server-->>Client: [2] <rpc-reply> +</rpc-reply> + Note over Server: notification is terminated. + +``` + +The diagram illustrates the termination of an alarm subscription. It shows two main entities: NETCONF Server/(O-RU) and NETCONF Client. The process begins with the client sending an RPC message containing a <close-session> operation, which is associated with a subscribed alarm notification to be closed. The server then responds with an RPC-reply message. Finally, a note indicates that the notification is terminated. + +Sequence diagram showing the procedure of terminating an alarm subscription between a NETCONF Server/(O-RU) and a NETCONF Client. + +Figure Annex3- 13 Procedure of terminating an alarm subscription + +## A3.8 File Management + +File transfers are done with sFTP. sFTP authenticates with account and password, which is compared with the present specification as following: + +Table Annex3- 11 + +| | O-RAN M-plane Specification | Modification herein | +|---------------------|----------------------------------------------------------------------------------|----------------------------------------------| +| Configuration files | a) account and password for authentication<br>b ) certificate for authentication | only account and password for authentication | + +### A3.8.1 File System Structure + +The file System structure of the O-RU<sub>8</sub> is represented as a logical structure that is used by the file management procedures. If the O-RU<sub>8</sub>'s physical file structure differs from the logical file structure defined below, the O-RU<sub>8</sub> is responsible for performing the mapping between the two structures. + +###### 1 A3.8.1.1 Directory definition + +2 The O-RU<sub>8</sub> shall support the standardized file directory. The following are definitions of the file +3 directory: + +4 O-RAN/log/ + +5 O-RAN/PM/ + +6 O-RAN/transceiver/ + +###### 7 A3.8.1.2 Specification comparison + +8 **Table Annex3- 12** + +| | O-RAN M-plane Specification | Modifications herein | +|---------------------|-------------------------------|----------------------------------| +| Configuration files | Supporting O-RAN/beamforming/ | No supporting O-RAN/beamforming/ | + +###### 9 A3.8.2 File list retrieve procedure + +10 This subsection describes file retrieve method which the O-DU<sub>8</sub>/NMS retrieves the file list from the +11 O-RU<sub>8</sub>. One or multiple files' information can be retrieved by one retrieve file list operation (use of +12 wildcard is allowed). The O-DU<sub>8</sub>/NMS triggers the retrieve file list operation from the O-RU<sub>8</sub>. + +13 The following rpc is used for retrieve file list operation: + +14 -rpc:retrieve-file-list + +15 - input + +16 - logical path: the logical path of files to be retrieved, wild-card is allowed; + +17 - file-name & file-name-filter: file name or file name filter, \* is the wild-card; + +18 - output + +19 - status: whether O-RU<sub>8</sub> accepted or rejected the retrieve file list request; + +20 - reject-reason: the reason why O-RU<sub>8</sub> rejects the request (only applicable if status is rejected); + +21 - file list: file list retrieved; + +22 The following shows retrieve file list sequence diagram: + +![Sequence diagram showing the file upload procedure between NETCONF Server/(O-RU) and NETCONF Client. The diagram illustrates two RPC calls: [1] retrieve-file-list and [2] retrieve-file-list. The first call is initiated by the Client to the Server, and the second call is initiated by the Server to the Client.](f97ea381db3efcf9e8a321aee2d73918_img.jpg) + +``` + +sequenceDiagram + participant Server as NETCONF Server/(O-RU) + participant Client as NETCONF Client + Note over Client: [1] <rpc> +<retrieve-file-list> +<input>.. +</input> +</retrieve-file-list> +</rpc> + Client->>Server: + Note over Server: [2] <rpc> +<retrieve-file-list> +<output>.. +</output> +</retrieve-file-list> +</rpc> + Server->>Client: + +``` + +Sequence diagram showing the file upload procedure between NETCONF Server/(O-RU) and NETCONF Client. The diagram illustrates two RPC calls: [1] retrieve-file-list and [2] retrieve-file-list. The first call is initiated by the Client to the Server, and the second call is initiated by the Server to the Client. + +Figure Annex3- 14 + +### A3.8.3 File upload procedure + +This subsection describes file upload method from O-RU<sub>s</sub> to O-DU/NMS. sFTP is used as upload means, and one file can be uploaded by one upload operation. The O-DU<sub>s</sub>/NMS triggers file upload operation to O-RU<sub>s</sub>. + +Simultaneous multiple file upload operations can be supported under the same sFTP connection between O-RU<sub>s</sub> to O-DU<sub>s</sub>/NMS. Following rpc parameters is used for upload operation: + +-rpc: file-upload + +- input + +- local-logical-file-path: the path of file to be uploaded locally (\* is allowed as wild-card); + +- remote-file-path: URI of file on the O-DU<sub>s</sub>/NMS; + +- output + +- status: whether O-RU<sub>s</sub> accepted or rejected the upload request; + +- reject-reason: the reason why O-RU<sub>s</sub> rejects the request (only applicable if status is rejected) + +The following shows the file upload sequence diagram: + +![Sequence diagram showing the file upload procedure between NETCONF Server/(O-RU) and NETCONF Client. The process involves three main steps: 1. File upload request, 2. File upload completion notification, and 3. Upload completion notification.](b50b0087e41ea5c72a2ccf7e1351b7c6_img.jpg) + +``` + +sequenceDiagram + participant Server as NETCONF Server/(O-RU) + participant Client as NETCONF Client + Note over Server: [1] <rpc> +<file-upload> +<input>.. +</input> +</file-upload> +</rpc> + Note over Client: [2] <rpc> +<file-upload> +<output>.. +</output> +</file-upload> +</rpc> + Note over Client: Waits for the notification from O-RU about the completion of the upload + Note over Server: O-RU Completes upload operation + Note over Server: [3] <notification> +<upload-notification>.. +</upload-notification> +</notification> + +``` + +Sequence diagram showing the file upload procedure between NETCONF Server/(O-RU) and NETCONF Client. The process involves three main steps: 1. File upload request, 2. File upload completion notification, and 3. Upload completion notification. + +Figure Annex3- 15 + +### A3.8.4 File download procedure + +This section describes file download method from O-RU<sub>s</sub> to O-DU<sub>s</sub>/NMS. sFTP is used as download means, and one file can be downloaded by one download operation. The O-DU<sub>s</sub>/NMS triggers file download operation. + +Multiple file download operations can be supported under one sFTP connection between O-RU<sub>s</sub> to O-DU<sub>s</sub>/NMS. + +Following rpc parameters is used for download operation: + +-rpc: file-download + +- input + +- local-logical-file-path: the path of file to be downloaded (\* is allowed as wild-card);; + +- remote-file-path: URI of file on the O-DU<sub>s</sub>/NMS; + +- output + +- status: whether O-RU<sub>s</sub> accepted or rejected the download request; + +- reject-reason: the reason why O-RU<sub>s</sub> rejects the request (only applicable if status is rejected) + +The following shows the file download sequence diagram: + +![Sequence diagram showing the file download process between a NETCONF Server/(O-RU) and a NETCONF Client. The process involves three steps: 1) The client sends a <file-download> request to the server. 2) The server sends a <file-download> response to the client. 3) The server sends a <download-notification> message to the client. The client then waits for the notification from the O-RU about the completion of the download.](d805e80c8e5854328b68b9624d6cf92d_img.jpg) + +``` + +sequenceDiagram + participant Server as NETCONF Server/(O-RU) + participant Client as NETCONF Client + + Note over Client: [1] <file-download> + Client->>Server: <rpc> <file-download> [1] <input>..</input> </file-download> </rpc> + Note over Server: [2] <file-download> + Server->>Client: <rpc> <file-download> [2] <output>..</output> </file-download> </rpc> + Note over Client: Waits for the notification from O-RU about the completion of the download + Note over Server: O-RU Completes download operation + Server->>Client: <notification> [3] <download-notification>..</download-notification> </notification> + +``` + +Sequence diagram showing the file download process between a NETCONF Server/(O-RU) and a NETCONF Client. The process involves three steps: 1) The client sends a request to the server. 2) The server sends a response to the client. 3) The server sends a message to the client. The client then waits for the notification from the O-RU about the completion of the download. + +Figure Annex3- 16 + +## A3.9 Synchronization plane management + +The O-RU<sub>s</sub> is responsible for managing its synchronization status, to select one or more synchronization input source(s) (based on vendor specific implementation) and assure that the resulting accuracy meets that required by the Radio Access Technology being implemented. + +### A3.9.1 CPRI SYNC + +#### A3.9.1.1 CPRI SYNC configuration + +The O-RU<sub>s</sub> obtains associated clock from CPRI without configuration of O-DU<sub>s</sub>. + +#### A3.9.1.2 CPRI SYNC status + +CPRI SYNC Status container is used to collect status information about the CPRI as a synchronization source. This information can be used to represent operational information and is useful for the operator to locate faults. This information is not used to obtain alarms automatically by the O-DU<sub>8</sub>. If the O-DU<sub>8</sub> is interested in CPRI SYNC status, it may send NETCONF <subscribe-notification> to the NETCONF Server in the O-RU<sub>8</sub>. Notifications are reported merely when the lock-state is changed. Before obtaining CPRI status information, O-DU<sub>8</sub> needs to make sure that the CPRI is supported by the O-RU<sub>8</sub> by querying supported-timing-reference-types. The following table contains related parameters of this container. + +reporting-period + +This parameter is used to define minimum time interval in seconds, sent by NETCONF Server. + +default: 10 + +lock-state + +This parameter is used to indicate whether the O-RU<sub>8</sub>'s clock system is locked in a line up state of a reference clock and a CPRI link recovered by a CPRI associated clock. The locked and unlocked states are defined by a specific implementation. + +##### - LOCKED: + +- a) the clock system is locked in the reference clock recovered by the CPRI associated clock, i.e. hardware PLL locked + +- b) CPRI links line up (or in a state that is considered to indicate that the CPRI links can be operated properly, F-status indication) + +note: LOCKED when both a) and b) are satisfied + +##### - UNLOCKED: + +- a) the clock system isn't locked in the reference clock recovered by the CPRI associated clock, i.e. hardware PLL unlocked + +- b) CPRI links line up (or in a state that is considered to indicate that the CPRI links can be operated properly, F-status indication) + +note: UNLOCKED when either a) or b) occurs. When a) occurs, alarm item is 18 synchronization error; When b) occurs, alarm item is 17 no sync source. + +sources + +This parameter describes a port selection of a clock source, controlled by the O-RU<sub>8</sub>. + +Refer to o-ran-sync-cpri.yang YANG Model for details. + +## A3.10 O-RU<sub>8</sub> U-plane Configuration + +This chapter refers specifically to the U-plane configuration of the O-RU<sub>8</sub> based on CPRI Option8 split, i.e., the U-plane configuration of the O-RU<sub>8</sub> according to the architectural model chapter. + +### A3.10.1 Specific Conventions + +#### A3.10.1.1 YANG model + +O-RU<sub>8</sub> U-plane under CPRI Option8 split is modeled with reference to O-RU<sub>7-2</sub> U-plane modeling under the condition of eCPRI Option7-2 split, o-ran-uplane-conf.yang and newly defined o-ran-uplane-conf-option8.yang. Main relations and differences between the two are compared in the following table. + +**Table Annex3- 13 U-plane comparison of Option7-2 and Option8** + +| eCPRI option7-2 | CPRI option8 | Main changes | +|----------------------------------|------------------------|------------------------------------------------------------------------------| +| static-low-level-tx-endpoint | static-tx-endpoint | new definition with reference; | +| static-low-level-rx-endpoint | static-rx-endpoint | new definition with reference; | +| low-level-tx-endpoint | tx-endpoint | new definition with reference; | +| low-level-rx-endpoint | rx-endpoint | new definition with reference; | +| low-level-tx-link | tx-link | new definition with reference; | +| low-level-rx-link | rx-link | new definition with reference; | +| endpoint-types | endpoint-types-option8 | new definition with reference;<br>original parameters seem be not applicable | +| endpoint-capacity-sharing-groups | not support | | +| endpoint-prach-group | not support | | +| tx-array-carriers | tx-array-carriers | reuse without supporting laa; | +| rx-array-carriers | rx-array-carriers | reuse | +| tx-arrays | tx-arrays | reuse | + +| | | | +|-----------------------------|-------------|-------| +| rx-arrays | rx-arrays | reuse | +| relations | relations | reuse | +| eaxc-id-group-configuration | not support | | +| general-config | not support | | + +1 + +2 + +3 + +###### 4 A3.10.1.2 Comparison of Specification Requirement + +5 The content of this chapter is newly written and is not relevant to the O-RAN specification. + +6 However, portions of this specification refer to the U-plane configuration under the O-RAN +7 specification eCPRI Option 7-2 split. + +###### 8 A3.10.2 Format of eaxc-id + +9 eaxc-id definition consistent with the O-RAN specification is used, ORAN-WG4.CUS.0-v03.00[2] +10 may be referred for the specific format. + +###### 11 A3.10.3 U-plane Endpoint Addressing + +12 For CPRI protocol-based connections, Option8 is used to split the O-RU<sub>8</sub>, and eaxc-id is used for +13 resource mapping and U-plane endpoint addressing. + +14 This method is applicable to end-to-end CPRI Option8 architecture. + +15 This method is also applicable to an architecture converting from eCPRI Option7-2 to CPRI +16 Option8, where O-DU<sub>8</sub> and FHGW<sub>7-2→8</sub> are connected based on an eCPRI Option7-2, FHGW<sub>7-2→8</sub> +17 and O-RU<sub>8</sub> are connected CPRI Option8. + +18 Different eaxc-ids correspond to different logical functions, such as cell, carrier, and space division +19 dataflow. The end-to-end dataflow from a processing end of the O-DU<sub>8</sub> to an antenna end of the O- +20 RU<sub>8</sub> are identified. + +21 During the configuration procedure: + +22 O-DU<sub>8</sub> configures eaxc-id for the O-RU<sub>8</sub> U-plane endpoint, and also specifies a physical antenna, +23 see tx-endpoint and rx-endpoint in o-ran-upline-conf-option8.yang which realizes mapping between +24 logical functions and O-RU<sub>8</sub> physical resources. + +O-DU<sub>8</sub> configures a relationship between U-plane endpoints and CPRI dataflow for the O-RU<sub>8</sub>, which realizes the addressing of CPRI dataflow and O-RU<sub>8</sub> U-plane endpoint. + +During data transmission, in combination with CPRI U-plane dataflow model of 4.3.1.2: + +In a downstream direction, the O-RU<sub>8</sub> obtains CPRI dataflow from the CPRI interface, and finds corresponding U-plane transmitting endpoint tx-endpoint according to eexc-id, and transmits the processed data to corresponding physical antenna. + +In an upstream direction, the O-RU<sub>8</sub> receives data from the physical antenna, and finds corresponding U-plane receiving endpoint rx-endpoint according to eexc-id, and transmits the processed data to the CPRI dataflow on corresponding CPRI interface. + +The following is rules for configuring the eexc-id by O-DU<sub>8</sub>: + +- For the same O-RU<sub>8</sub>, only one eexc-id is configured for each dataflow in the same direction (e.g., upstream or downstream), and different eexc-ids are configured for different dataflow. eexc-ids can be the same for dataflow in different directions (upstream and downstream) for the same O-RU<sub>8</sub>. +- For the same upstream U-plane data stream, + - ✓ lower-level-tx-endpoint in FHM<sub>8</sub> is configured with the same eexc-id with the sending endpoint tx-endpoint in O-RU<sub>8</sub>. +- For the same downstream U-plane data stream. + - ✓ Low-level-rx-endpoint in the FHM<sub>8</sub> with the same eexc-id configured with the receiving endpoint rx-endpoint in the O-RU<sub>8</sub>. +- For the same user-facing data stream for the same shared cell. + - ✓ Sending endpoint tx-endpoint in different O-RU<sub>8</sub>s configured with the same eexc-id. + - ✓ Receive endpoint rx-endpoint in different O-RU<sub>8</sub>s configured with the same eexc-id. +- For the same O-RU<sub>8</sub>, only one eexc-id is configured for each dataflow in the same direction (e.g., upstream or downstream), and different eexc-ids are configured for different dataflow. The eexc-ids can be the same for dataflow in different directions (upstream and downstream) for the same O-RU<sub>8</sub>. +- For the same upstream U-plane dataflow, + - ✓ lower-level-tx-endpoint in FHM<sub>8</sub> is configured with the same eexc-id as the tx-endpoint in O-RU<sub>8</sub>; +- For the same downstream U-plane dataflow, + - ✓ low-level-rx-endpoint in FHM<sub>8</sub> is configured with the same eexc-id as the rx-endpoint in O-RU<sub>8</sub>; +- For the same U-plane dataflow for the same shared cell, + - ✓ tx-endpoints in different O-RU<sub>8</sub> are configured with the same eexc-id; + +- ✓ rx-endpoints in different O-RU<sub>8</sub> are configured with the same eaxc-id; + +O-RU<sub>8</sub> shall reject a configuration request that violates the above rules. + +### A3.10.4 U-plane Configuration + +O-RU<sub>8</sub> U-plane routing configuration under CPRI Option 8 split is shown below. + +For more information, refer to o-ran-uplane-conf-option8.yang. + +![Diagram illustrating the Option-8 u-plane configuration (o-ran-uplane-conf-option8.yang) and its relationship to CPRI transport configuration.](c04e9bcc95cc30242782e807df721353_img.jpg) + +The diagram illustrates the Option-8 u-plane configuration (o-ran-uplane-conf-option8.yang) and its relationship to CPRI transport configuration. The CPRI transport configuration is shown on the left, and the Option-8 u-plane configuration is shown on the right. + +**CPRI transport configuration:** + +- o-ran-processing-element-cpri** (yellow box) contains: transport-session-type, element-name, interface-name, cpri-flow (AxCIInfos), and .... It has a 1-to-0..n relationship with **ietf-interface (with o-ran augmentations)** (yellow box). + +**Option-8 u-plane configuration (o-ran-uplane-conf-option8.yang):** + +- tx-array-carrier** (yellow box) contains: config true, absolute-frequency-center, center-of-channel-bandwidth, channel-bandwidth, and .... It has a 1-to-1..n relationship with **tx-link** (yellow box). +- tx-link** (yellow box) contains: config true, processing-element, tx-array-carrier, and tx-endpoint. It has a 1-to-\* relationship with **tx-endpoint** (yellow box). +- tx-endpoint** (yellow box) contains: config true, eaxc-id, and .... It has a 1-to-1 relationship with **static-tx-endpoint** (grey box). +- static-tx-endpoint** (grey box) contains: config false, endpointtype, and array. It has a 1-to-1..\* relationship with **relations** (grey box). +- rx-array-carrier** (yellow box) contains: config true, absolute-frequency-center, center-of-channel-bandwidth, channel-bandwidth, and .... It has a 1-to-1..n relationship with **rx-link** (yellow box). +- rx-link** (yellow box) contains: config true, processing-element, rx-array-carrier, and rx-endpoint. It has a 1-to-\* relationship with **rx-endpoint** (yellow box). +- rx-endpoint** (yellow box) contains: config true, eaxc-id, and .... It has a 1-to-1 relationship with **static-rx-endpoint** (grey box). +- static-rx-endpoint** (grey box) contains: config false, endpointtype, and array. It has a 1-to-1..\* relationship with **relations** (grey box). +- relations** (grey box) has a 1-to-1 relationship with **relations** (grey box). + +Diagram illustrating the Option-8 u-plane configuration (o-ran-uplane-conf-option8.yang) and its relationship to CPRI transport configuration. + +Figure Annex3- 17 O-RU<sub>8</sub> U-plane routing configuration under Option8 split + +#### Pre-condition: + +M-plane connection between the NETCONF client and the O-RU<sub>8</sub> is established. + +#### Post-condition: + +U-plane routing configuration is completed. + +#### Basic procedure: + +- 1) NETCONF client gets the intrinsic properties of the O-RU<sub>8</sub> by reading the following parameters via RPC edit-config: + - o-ran-uplane-conf-option8.yang + - ✓ tx-arrays + - ✓ rx-arrays + - ✓ static-tx-endpoints list + - ✓ static-rx-endpoints list + - o-ran-interfaces-cpri.yang + - ✓ interface element +- 2) NETCONF client checks relationships between the elements read in step 1): + - ✓ static-tx-endpoint element and tx-array element; + - ✓ static-rx-endpoint element and rx-array element; + - ✓ static-tx-endpoint element and interface element; + - ✓ static-rx-endpoint element and interface element; + - ✓ tx-arrays, rx-arrays and element thereof. +- 3) NETCONF client checks whether the following configurations meet the user cell configuration requirements, e.g., being connected with a specific antenna array and able to support the target service type, etc. + - ✓ tx-endpoint + - ✓ rx-endpoint +- 4) NETCONF client assigns eaxc-id for tx-endpoint/rx-endpoint. The assignment rules see U-plane endpoint addressing, and configures the eaxc-id to a terminal by RPC edit-config. + - ✓ tx-endpoint + - ✓ rx-endpoint +- 5) NETCONF client creates a carrier by RPC edit-config + - ✓ tx-array-carriers + - ✓ rx-array-carriers +- 6) NETCONF client configures the U-Plane interface for the northbound CPRI interface via RPC edit-config + - ✓ processing-elements + - ✓ AxC-information +- 7) NETCONF client establishes U-plane routing for the O-RU<sub>8</sub> by creating and configuring the following parameters via RPC edit-config, and thus associating the CPRI northbound interface, the transceiver terminal, and the carrier. + - ✓ tx-links + - ✓ rx-links +- 8) NETCONF client activates the carrier via RPC edit-config + - ✓ tx-array-carriers.active = ACTIVE + - ✓ rx-array-carriers.active = ACTIVE + +#### Example of U-plane configuration: + +![Sequence diagram showing the interaction between NETCONF Server and NETCONF Client for option8 U-plane configuration and carrier creation. The process includes querying O-RU data, checking relationships, modifying configurations, creating carriers, and finally reporting the carrier state as READY.](13c0aa07902de223149e54b4cad73eab_img.jpg) + +option8 U-plane Configuration and Carrier Creation Examples + +``` + +sequenceDiagram + participant Server as NETCONF Server + participant Client as NETCONF Client + + Note over Server: Querying O-RU read-only data via RPC get-config + Note over Server: o-ran-uplane-conf-option8:tx-arrays + Note over Server: o-ran-uplane-conf-option8:rx-arrays + Note over Server: o-ran-uplane-conf-option8:static-tx-endpoints + Note over Server: o-ran-uplane-conf-option8:static-rx-endpoints + Note over Server: o-ran-interfaces-cpri:interface + + Note over Client: Checking the relationship between configuration data below + Note over Client: static-tx-endpoint vs. tx-array + Note over Client: static-rx-endpoint vs. rx-array + Note over Client: static-tx-endpoint vs. interface + Note over Client: static-rx-endpoint vs. interface + Note over Client: tx-arrays vs. rx-arrays + + Note over Client: Checking whether the configuration data below is consistent with user cell configuration requirement + Note over Client: tx-endpoint + Note over Client: rx-endpoint + + Note over Client: Assigning eaxc-id, and setting each bit mask simultaneously + Note over Client: o-du-port-bitmask + Note over Client: band-sector-bitmask + Note over Client: ccid-bitmask + Note over Client: ru-port-bitmask + + Note over Server: Modifying configurations by using RPC edit-config + Note over Server: rx-endpoint.eaxc-id + Note over Server: rx-endpoint.eaxc-id + + Note over Server, Client: U-plane connection successfully + + Note over Client: tx-array-carriersnum.= tx-arraysnum.* component carriers num. + Note over Client: rx-array-carriers num.= rx-arrays num.* component carriers num. + + Note over Server: Creating configuration data by using RPC edit-config + Note over Server: o-ran-uplane-conf-option8:tx-array-carriers + Note over Server: o-ran-uplane-conf-option8:rx-array-carriers + Note over Server: o-ran-uplane-conf-option8:tx-links + Note over Server: o-ran-uplane-conf-option8:rx-links + Note over Server: o-ran-processing-element:processing-elements-cpri + + Note over Server, Client: Creating carrier successfully + + Note over Server: Modifying configuration by using RPC edit-config + Note over Server: o-ran-uplane-conf-option8:tx-array-carrier.active = ACTIVE + Note over Server: o-ran-uplane-conf-option8:rx-array-carrier.active = ACTIVE + + Note over Client: [1] reporting carrier state tx-array-carrier.state==READY[notification] + + Note over Server, Client: onAir + +``` + +Sequence diagram showing the interaction between NETCONF Server and NETCONF Client for option8 U-plane configuration and carrier creation. The process includes querying O-RU data, checking relationships, modifying configurations, creating carriers, and finally reporting the carrier state as READY. + +Figure Annex3- 18 + +### A3.10.5 Carrier State Management + +The state management of carrier is consistent with that described in the O-RAN specification, unless otherwise specified. The following table describes a comparison of value range supported by this specification and the O-RAN specification. + +**Table Annex3- 14 Comparison of carrier** + +| | O-RAN Specification | This specification | +|-------------------------------------------------------|---------------------|---------------------------------| +| Value range of carrier active, configurable parameter | INACTIVE (default) | the same as O-RAN specification | +| | ACTIVE | the same as O-RAN specification | +| | SLEEP | the same as O-RAN specification | +| Value range of carrier state, read-only parameter | DISABLED | the same as O-RAN specification | +| | BUSY | no supported | +| | READY | the same as O-RAN specification | + +## A3.11 Delay Measurement and Management + +### A3.11.1 Convention + +This specification is direct at indoor distribution scenario, in which current O-RU<sub>s</sub> are all at single-level leaf stage, and do not involve cascade or multiple uplink. Therefore, this specification has the following scenario conventions: + +O-RU<sub>s</sub> cascade, not involved. + +O-RU<sub>s</sub> multiple uplink, not involved. + +O-RU<sub>s</sub> multiple uplink and cascade, not involved. + +### A3.11.2 Delay Model + +CPRI protocol based on the Option 8 physical layer functional split is used for a fronthaul interface between the FHM<sub>8</sub> and the O-RU<sub>8</sub>. The model presented in this section supports both O-RU<sub>8</sub> in indoor distribution that docks the FHM<sub>8</sub>, and O-RU<sub>8</sub> in outdoor macro station in the future. + +The CPRI delay management model is holistic in nature and often needs to be described from DU south-port to air port for complete representation. FIG. 4.9-1 lists the delay management model given in CPRI V7.0 Section 4.2.9. + +![Figure Annex3- 19 CPRI delay management model (cascade). This diagram illustrates a cascaded CPRI network. On the left is a 'REC' (Receiver) block with a 'master port' containing points R1 and R4. In the center is an 'RE' (Radio Equipment) block with a 'networking port' containing points RB1 and RB4, and a 'slave port' containing points RB2 and RB3. On the right is another 'RE' block with a 'slave port' containing points R2 and R3. Arrows show data flow: from REC master port to RE networking port (T12(1), T14(1), T34(1)), from RE networking port to RE slave port (T12(2), T34(2)), and from RE slave port to the final RE block (T2a, Ta3). A 'Ra' antenna is connected to the final RE block. Delays are indicated: TBdelay DL(1) and TBdelay UL(1) at the RE networking port, and Toffset(1) and Toffset at the RE slave port.](8fed63f01ee5186e7b7f9cf4c271c46b_img.jpg) + +Figure Annex3- 19 CPRI delay management model (cascade). This diagram illustrates a cascaded CPRI network. On the left is a 'REC' (Receiver) block with a 'master port' containing points R1 and R4. In the center is an 'RE' (Radio Equipment) block with a 'networking port' containing points RB1 and RB4, and a 'slave port' containing points RB2 and RB3. On the right is another 'RE' block with a 'slave port' containing points R2 and R3. Arrows show data flow: from REC master port to RE networking port (T12(1), T14(1), T34(1)), from RE networking port to RE slave port (T12(2), T34(2)), and from RE slave port to the final RE block (T2a, Ta3). A 'Ra' antenna is connected to the final RE block. Delays are indicated: TBdelay DL(1) and TBdelay UL(1) at the RE networking port, and Toffset(1) and Toffset at the RE slave port. + +**Figure Annex3- 19 CPRI delay management model (cascade)** + +CPRI start point of the system in which the O-RU<sub>8</sub> located may be O-DU<sub>8</sub> (corresponding) that provides CPRI interface, or it may be CPRI interface FHM<sub>8</sub> for converting from 7-2x to 8, so the traditional REC in the CPRI model needs to be generalized to the CPRI Master to achieve an independent and complete description of the O-RU<sub>8</sub> model, as shown in FIG. 4.9-2 for details. + +![Figure Annex3- 20 Relationship between O-RU8 and CPRI Master. This diagram shows the relationship between a 'CPRI Master' block on the left and an 'O-RU' block on the right. The CPRI Master has points R1 and R4. The O-RU has points R2 and R3. An orange oval labeled 'Indefinite multi-level CPRI transmission' connects the two. Arrows show data flow: from CPRI Master to O-RU (T12, T34) and from O-RU to CPRI Master (T14). The O-RU also has an antenna 'Ra' connected to it. Delays are indicated: Toffset between the two blocks.](e44a1b669fba81691549d3002c95c724_img.jpg) + +Figure Annex3- 20 Relationship between O-RU8 and CPRI Master. This diagram shows the relationship between a 'CPRI Master' block on the left and an 'O-RU' block on the right. The CPRI Master has points R1 and R4. The O-RU has points R2 and R3. An orange oval labeled 'Indefinite multi-level CPRI transmission' connects the two. Arrows show data flow: from CPRI Master to O-RU (T12, T34) and from O-RU to CPRI Master (T14). The O-RU also has an antenna 'Ra' connected to it. Delays are indicated: Toffset between the two blocks. + +**Figure Annex3- 20 Relationship between O-RU<sub>8</sub> and CPRI Master** + +The elliptical region in the figure may be a cable, an FHM<sub>8</sub> of a primary CPRI interface, a multi-level CPRI FHM<sub>8</sub> cascade or an indefinite multi-level CPRI O-RU<sub>8</sub> and so on. In either above cases, the delay relationship between a given O-RU<sub>8</sub> and the CPRI Master is limited to the four elements, R1, R4, T12, and T34, which specifically are: + +point R1: relationship between a CPRI frame header and absolute time; relationship between IQ data and CPRI frame header; + +point R4: no need particular attention. + +T12: TX's (generalized) transmission delay. + +T34: RX's (generalized) transmission latency. + +In order to further enhance the expressiveness of the model, it may be useful to define: + +Offset of the CPRI frame header of the point R1 relative to absolute time: **TR1\_Offset** in Tc, which is used as a descriptive reference for time of the CPRI system. Each R1 point has one. Optionally, this time reference can be conventionally specified as absolute time by default when it is not required. + +Relative position of the IQ data at point R1 and the CPRI frame header: **DI\_Offset** in Tc with reference to IR protocol, which describes time offset relationship between the IQ data and the CPRI frame. + +#### A3.11.2.1 Measurement Model + +![Figure Annex3- 21 Delay measurement after the O-RU8 M-plane channel is normally established. The diagram shows a network topology with three main blocks: REC (Receiver), RE (Radio Equipment), and a central networking block. REC has a master port with points R1 and R4. RE has a slave port with points RB2 and RB3, and a master port with points RB1 and RB4. The networking block has a slave port with points RB2 and RB3, and a master port with points RB1 and RB4. Arrows indicate data flow and delays: T12(1) from R1 to RB2, T12(2) from RB1 to R2, T14(1) from R1 to R4, T34(1) from RB3 to R4, T34(2) from RB4 to R3, Toffset(1) from RB2 to RB3, Toffset from RB1 to RB4, TBdelay DL(1) from RB2 to the networking block, TBdelay UL(1) from the networking block to RB3, T2a from R2 to an antenna Ra, and Ta3 from R3 to an antenna Ra.](4433125b54c88c579c8ae01c15cb991a_img.jpg) + +Figure Annex3- 21 Delay measurement after the O-RU8 M-plane channel is normally established. The diagram shows a network topology with three main blocks: REC (Receiver), RE (Radio Equipment), and a central networking block. REC has a master port with points R1 and R4. RE has a slave port with points RB2 and RB3, and a master port with points RB1 and RB4. The networking block has a slave port with points RB2 and RB3, and a master port with points RB1 and RB4. Arrows indicate data flow and delays: T12(1) from R1 to RB2, T12(2) from RB1 to R2, T14(1) from R1 to R4, T34(1) from RB3 to R4, T34(2) from RB4 to R3, Toffset(1) from RB2 to RB3, Toffset from RB1 to RB4, TBdelay DL(1) from RB2 to the networking block, TBdelay UL(1) from the networking block to RB3, T2a from R2 to an antenna Ra, and Ta3 from R3 to an antenna Ra. + +**Figure Annex3- 21 Delay measurement after the O-RU<sub>8</sub> M-plane channel is normally established:** + +after receiving a delay measurement request message, the O-RU<sub>8</sub> reports its own delay measurements to the BBU via a delay measurement response message, which should include the following delays: + +- Toffset +- T2a +- Ta3 +- TBdelay DL +- TBdelay UL + +N(unit:basic frame, the difference of the frame position at RB3 relative to RB4 + +N is a specific concept of cascade RU, which is directly 0 in non-cascade mode. + +#### A3.11.2.2 Timing model + +Independence of the O-RU<sub>8</sub> model can be improved by detaching time (in frame number form) from delay configuration model. Based on TR1\_Offset and T12, O-RU<sub>8</sub> can obtain global time in frame number form. + +###### 1 A3.11.2.3 Dataflow delay configuration model + +![Figure Annex3- 22 Schematic diagram of O-RU8 side delay configuration compensation point. The diagram shows a CPRI Master connected to two O-RUs (R1, R4 and R2, R3). The CPRI Master sends data to R1 and R4, which then transmits to R2 and R3 via an 'Indefinite multi-level CPRI transmission' block. The O-RU block contains two sub-units, T2a and Ta3, which are connected to an antenna (Ra). The diagram labels various delay parameters: T12, T34, Toffset, T_Cal_DL, and T_Cal_UL.](48388a9455aead438d74cca6d831659d_img.jpg) + +Figure Annex3- 22 Schematic diagram of O-RU8 side delay configuration compensation point. The diagram shows a CPRI Master connected to two O-RUs (R1, R4 and R2, R3). The CPRI Master sends data to R1 and R4, which then transmits to R2 and R3 via an 'Indefinite multi-level CPRI transmission' block. The O-RU block contains two sub-units, T2a and Ta3, which are connected to an antenna (Ra). The diagram labels various delay parameters: T12, T34, Toffset, T\_Cal\_DL, and T\_Cal\_UL. + +2 +3 **Figure Annex3- 22 Schematic diagram of O-RU<sub>8</sub> side delay configuration compensation point** + +![Figure Annex3- 23 Schematic diagram of O-RU8 side delay configuration. This diagram shows two horizontal timelines. The top timeline represents downlink (DL) and includes segments for T12, T_Cal_DL, and T2a. The bottom timeline represents uplink (UL) and includes segments for T34, T_Cal_UL, and Ta3. Both timelines end with a vertical line representing the antenna interface.](a3d8cfa5128c9935be635924a7eb1298_img.jpg) + +Figure Annex3- 23 Schematic diagram of O-RU8 side delay configuration. This diagram shows two horizontal timelines. The top timeline represents downlink (DL) and includes segments for T12, T\_Cal\_DL, and T2a. The bottom timeline represents uplink (UL) and includes segments for T34, T\_Cal\_UL, and Ta3. Both timelines end with a vertical line representing the antenna interface. + +4 +5 **Figure Annex3- 23 Schematic diagram of O-RU<sub>8</sub> side delay configuration** + +6 Under this model, the O-RU<sub>8</sub> can take on all of delay compensation requirements independently, or +7 it can take on part of the delay configuration requirements under the control of the CPRI Master. + +###### 8 A3.11.3 Delay Parameter Modeling + +9 **Table Annex3- 15 O-RU<sub>8</sub> delay parameters** + +| Type of delay parameter | Name of delay parameter | Attribution level modeling of parameter | Description | +|----------------------------------------------------------|-------------------------|-----------------------------------------|----------------------------------------------------------------------------------------------------------| +| RU delay attribution parameter, reported by RU, DU read- | Toffset | RU level parameter | one value per RU, in unit of ns | +| | T2a | carrier specification parameter | one parameter per carrier specification, the carrier specification includes:<br>1. carrier format NR/LTE | + +| | | | | +|-----------------------------------------------|---------------|---------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------| +| only | | | 2. spectrum bandwidth<br>3. subcarrier spacing<br>the same value is still used when multiple CPRI uplink ports of RU are involved<br>in unit of ns | +| | Ta3 | the same as above | the same as above | +| | TBdelayDl | RU level parameter | same value when multipath CPRI cascades are involved (very unlikely to exist)<br>in unit of ns | +| | TBdelayUl | the same as above | the same as above | +| | T_Cal_DL_M AX | carrier specification parameter | the parameter belongs to a digital domain and is not affected by the frequency band, with reference to T2a, Ta3 modeling<br>in unit of ns | +| | T_Cal_UL_M AX | the same as above | the same as above | +| | N | Each pair of cascade ports | in unit of Tc (basic frame period); pass-by data introduced by cascade, frame header alignment compensation. | +| RU delay configuration parameter, DU readable | T_Cal_DL | carrier antenna level parameter | one value per carrier antenna, the carrier antenna includes:<br>1. carrier<br>2. physical antenna<br>For example, a 4T4R device single-carrier | + +| | | | | +|-----------------|-------------------|---------------------------------|---------------------------------------------------------------------------------------------------------------------------------| +| and<br>writable | | | has four T_Cal_DL configuration points; a 4T4R device dual-carrier has eight T_Cal_DL configuration points<br><br>in unit of ns | +| | T_Cal_UL | the same as above | the same as above | +| | T12 | RU.OptPort level parameter | CPRI T12, in unit of ns | +| | T34 | RU.OptPort level parameter | CPRI T34, in unit of ns | +| | DL_Offset | carrier antenna level parameter | Offset relationship between IQ data and CPRI frame header, in unit of Tc | +| | <b>TR1_Offset</b> | RU.OptPort level parameter | Offset of frame number of point R1 relative to absolute time, in unit of Tc.<br><br>Optional parameter. | + +1 + +###### 2 A3.11.3.1 Scenario involved TR1\_Offset + +3 In the model given in FIG. 4.9.2.3-1, the frame number at the start point R1 of the CPRI reference +4 time, includes two cases. + +5 Case 1: FDD + +6 In LTE FDD and similar systems that do not require alignment of 1PPS to work, the CPRI +7 frame number at CPRI master exit is not required. + +8 Case 2: TDD + +9 Under LTE TDD, NR systems, gap frame header has an exact relationship to 1PPS. The CPRI +10 frame number at the CPRI master exit is aligned to 1PPS by default. + +11 The CPRI frame number at the CPRI master exit may not be aligned to 1PPS in Case 2 under +12 certain usages. Defining parameter TR1\_Offset in this case helps to supplement the expression + +1 capability of delay configuration system, and RU can still recover the CPRI frame number aligned +2 with 1PPS by using TR1\_Offset, t12 in this case. + +###### 3 A3.11.3.2 Parameter grouping + +4 Parameters to be measured at this level: + +5       Toffset, one value for each RU, regardless of port. + +6       T2a, Ta3, T\_Cal\_DL\_MAX, T\_Cal\_UL\_MAX, related to format, carrier bandwidth, +7 subcarrier spacing + +8 Parameters required to be measured for cascade (this specification does not refer to RU cascade, +9 TBD): + +10       TBdelayDL, TBdelayUL, N + +11 CPRI link-related configuration parameters: + +12       T12, T34, TR1\_Offset + +13 IQ data flow-related configuration parameters: + +14       T\_Cal\_DL, DL\_Offset, T\_Cal\_UL + +###### 15 A3.11.3.3 Modeling after grouping + +16 yang file: o-ran-delay-management-ru-cpri.yang + +17 Measurement parameter required for this level: ru-delay-profile + +18 Measurement parameter required for cascade: ru-delay-profile-cascade-related + +19 CPRI link related configuration parameter: ru-delay-config-cpri-link-related + +20 IQ dataflow related configuration parameter: ru-delay-config-data-flow-related + +###### 21 A3.11.3.3.1 Modeling description of ru-delay-profile/ru-delay-profile-list- + +###### 22 radio-related + +23 The reference factors for O-RAN's existing delay management modeling are carrier bandwidth and +24 subcarrier spacing, and neither format, nor frequency point is included. + +25 In CPRI class device practice, CPRI RU delay is mainly influenced by the format, carrier, and +26 subcarrier spacing, with the format having the greatest influence and the latter two having relatively +27 little influence. Factors such as frequency point have a small impact and are usually self-digested +28 within the device without exposing the differences externally. + +Therefore, this part of the parameter is modeled as follows: + +Format Bandwidth Subcarrier spacing T2a Ta3 T\_Cal\_DL\_MAX T\_Cal\_UL\_MAX + +The three underlined elements are used as table lookup keys to uniquely specify a set of relevant experimental parameters within the current RU. In terms of value, formats such as COMMON, LTE, NR, etc. are defined; frequency is expressed in kHz; subcarrier spacing is expressed in Hz. The format COMMON means wildcard, and frequency and subcarrier interval of 0 means wildcard. + +The model has the following usage: + +case a: O-RU<sub>s</sub> only have one set of delay paras,. + +COMMON 0 0 t2a ta3 ... + +case b: LTE use one set of delay paras, NR use another set of paras. + +COMMON 0 0 t2a ta3 ... + +case c: LTE NR use 2 set of delay paras... + +LTE 5000 15000 ... + +LTE 10000 15000 ... + +NR 100000 30000 ... + +... + +Recommended usage: + +**Table Annex3- 16** + +| | | +|-----------------------------------|---------------------------------------------------------------------------------------| +| LTE single mode<br>single-carrier | COMMON 0 0 t2a ta3 T_Cal_DL_MAX T_Cal_UL_MAX | +| LTE single mode<br>multi-carrier | COMMON 0 0 t2a ta3 T_Cal_DL_MAX T_Cal_UL_MAX | +| NR single mode<br>single-carrier | COMMON 0 0 t2a ta3 T_Cal_DL_MAX T_Cal_UL_MAX | +| NR single mode<br>multi-carrier | COMMON 0 0 t2a ta3 T_Cal_DL_MAX T_Cal_UL_MAX | +| LTE/NR bimode | LTE 0 0 t2a ta3 T_Cal_DL_MAX T_Cal_UL_MAX<br>NR 0 0 t2a ta3 T_Cal_DL_MAX T_Cal_UL_MAX | + +##### A3.11.3.3.2 Modeling description of ru-delay-config-data-flow-related + +Modeling perspective: + +1 The CPRI RU delay configuration tends to be passive, i.e., by means of DU measuring, calculating, +2 and sending pending configurations to RU. + +3 Modeling approach: + +4 In the RU perspective, a configuration model can be built based on its configuration points. +5 However, this approach is not easy to use externally because the configuration points within the RU +6 may be complex in multi-carrier and multi-format scenarios. + +7 Mode selection: + +8 From an external point of view, link between the DU/RU IQ dataflow is the eexc-id. “Information +9 pair” of eexc-id & delay is used as the basic element herein. On the one hand, DU is easy to +10 express, and on the other hand, RU is easy to use. + +11 In detail, because the same eexc-id or different eexc-ids may be used for upstream and downstream +12 of the same carrier antenna, it is not convenient to describe both DL and UL under one eexc-id. For +13 this reason, DL and UL are modeled separately: + +14 dl\_cal\_ru\_list : eexc-id and t\_cal\_dl, DL\_Offset + +15 ul\_cal\_ru\_list : eexc-id and t\_cal\_ul + +###### 16 A3.11.4 Delay Management Procedure + +17 The following figure shows a delay management procedure. + +![Sequence diagram showing the delay management procedure between DU and RU. The DU sends a <rpc><get-config> message to the RU. The RU responds with an Ack: ru-delay-profile, include Toffset, T2a, Ta3, T_Cal_DL_MAX, T_Cal_UL_MAX. The DU then performs a Query 'T14' from CPRI master and a Calculation. The DU sends a <rpc><edit-config> message to the RU. The RU responds with Configuration. The DU then performs Configuration 'if needed'.](29a2d139f009f5b5feaa9cd1192195a1_img.jpg) + +``` + +sequenceDiagram + participant DU + participant RU + DU->>RU: <rpc><get-config> +o-ran-delay-management-ru-cpri/ru-delay-profile + RU-->>DU: Ack: ru-delay-profile, include +Toffset, T2a, Ta3, T_Cal_DL_MAX, T_Cal_UL_MAX + Note over DU: Query "T14" from +CPRI master + Note over DU: Calculation + DU->>RU: <rpc><edit-config> +o-ran-delay-management-ru-cpri, include: +ru-delay-config-cpri-link-related +ru-delay-config-data-flow-related + RU-->>DU: Configuration + Note over DU: Configuration +"if needed" + +``` + +Sequence diagram showing the delay management procedure between DU and RU. The DU sends a message to the RU. The RU responds with an Ack: ru-delay-profile, include Toffset, T2a, Ta3, T\_Cal\_DL\_MAX, T\_Cal\_UL\_MAX. The DU then performs a Query 'T14' from CPRI master and a Calculation. The DU sends a message to the RU. The RU responds with Configuration. The DU then performs Configuration 'if needed'. + +Figure Annex3- 24 Delay management procedure + +## A3.12 Log Management + +### A3.12.1 Specific Conventions + +#### A3.12.1.1 YANG model + +o-ran-troubleshooting.yang: defining O-RU<sub>s</sub>'s fault location log + +o-ran-trace.yang: defining O-RU<sub>s</sub>'s tracking log + +#### A3.12.1.2 Comparison of specification requirements + +Comparison of the differences between this chapter and the O-RAN Management Plane Specification [1] is shown in the following table: + +Table Annex3- 17 Comparison of differences of log management related specification + +| | O-RAN Management Plane Specification | Requirements of the present specification | +|--------------------------------|-----------------------------------------------------------------------------------------|-------------------------------------------| +| Compression format of Log file | <ul style="list-style-type: none"> <li>• .gz (DEFLATE)</li> <li>• .lz4 (LZ4)</li> </ul> | gz | + +| | | | +|---------------|---------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>• .xz (LZMA2 - xz utils)</li> <li>• .zip (DEFLATE - zlib library)</li> </ul> | | +| Log file size | not defined (recommending that the upload time be controlled within 3 minutes) | the same as O-RAN specification<br><br>upper limit for log files is defined by vender, file can be renamed and dated | + +### A3.12.2 Fault Location Log + +A log used to locate a fault after system startup. It is recommended that the logs be graded and that only errors and logs that affect the operation of the system be introduced to default location log. + +#### A3.12.2.1 Overview of YANG model + +o-ran-troubleshooting.yang: defining fault location log of O-RU<sub>s</sub> + +namespace: urn:o-ran:troubleshooting:1.0 + +**RPC-reply:** + +Table Annex3- 18 + +| Parameter name | Parameter definition | Parameter type | Parameter value | Importance | +|-----------------------|------------------------------------------------------------------------------|----------------|--------------------|------------| +| <b>status</b> | RPC post-condition | enumeration | SUCCESS<br>FAILURE | mandatory | +| <b>failure-reason</b> | reason for failure (coming into effect when status takes a value of FAILURE) | string | “ ” | mandatory | + +**RPC:** + +<start-troubleshooting-logs> starts to create troubleshooting Log file, logging time starts from system startup to the time when this RPC is received + +<stop-troubleshooting-logs> stops creating troubleshooting Log file, and ignores this RPC after sending out Notification (since the file has already been created) + +##### Notification: + +<troubleshooting-logs-generated> notifies that O-RU<sub>8</sub> controller that the troubleshooting Log file has been created, and carries Log filename. + +#### A3.12.2.2 Procedure requirements + +After the O-RU<sub>8</sub> software system starts, it automatically starts to collect Logs and store them in the memory, and writes them to the file when it receives creating file command. + +(1) Triggering the O-RU<sub>8</sub> with <start-troubleshooting-logs> to create a troubleshooting logs file, and the O-RU<sub>8</sub> replies rpc-reply to indicate whether the operation is successful or not. + +(2) If rpc-reply shows the operation is success, the O-RU<sub>8</sub> starts to create fault location log file, and sends <troubleshooting-logs-generated> after creating all Log files, to notify the O-RU<sub>8</sub> that controller file has been created and is waiting to be collected, with all the URLs of the log files carried therein. See File Management for file collection method. + +(3) The O-RU<sub>8</sub> controller may send <stop-troubleshooting-logs> to stop the log file creation procedure if the rpc-reply indicates fail or if it is a long time before receiving the <troubleshooting-logs-generated> notification. + +![Sequence diagram illustrating the Fault location log procedure between NETCONF Server(O-RU) and NETCONF Client.](2096a255a9fc7ea811043d3b539b259a_img.jpg) + +``` + +sequenceDiagram + participant Server as NETCONF Server(O-RU) + participant Client as NETCONF Client + Note over Server: O-RU starts collecting the troubleshooting logs. + Client->>Server: [1] <rpc> <start-troubleshooting-logs> + Note over Server: O-RU starts creating the troubleshooting log files. + Server->>Client: [2] <rpc-reply> <troubleshooting-status-grouping> + alt [successful notification case] + Note over Server: O-RU completed to create troubleshooting log files before start rpc + Server->>Client: [3] <notification> <troubleshooting-log-generated> (URLs of all log files that contain troubleshooting logs collected before start rpc.) + else [no notification is signalled from O-RU] + Client->>Server: [4] <rpc> <stop-troubleshooting-logs> + Note over Server: O-RU stops creating troubleshooting log files. + Server->>Client: [5] <rpc-reply> <troubleshooting-status-grouping> + end + +``` + +Sequence diagram illustrating the Fault location log procedure between NETCONF Server(O-RU) and NETCONF Client. + +Figure Annex3- 25 Fault location log procedure + +### A3.12.3 Trace Log + +Trace log is used to record a complete log of the system over a period of time and is controlled by the O-RU<sub>8</sub> Controller. + +#### A3.12.3.1 YANG model overview + +o-ran-trace.yang: defining Trace Log of O-RU<sub>8</sub>. + +namespace: urn:o-ran:trace:1.0 + +##### RPC-reply: + +Table Annex3- 19 + +| Parameter name | Parameter definition | Parameter type | Parameter value | Importance | +|-----------------------|------------------------------------------------------------------------------|----------------|--------------------|------------| +| <b>status</b> | RPC post-condition | enumeration | SUCCESS<br>FAILURE | mandatory | +| <b>failure-reason</b> | reason for failure (coming into effect when status takes a value of FAILURE) | string | “ ” | mandatory | + +##### RPC: + +<start-trace-logs> starts to create trace log file, logging time starts from receiving RPC to receiving <stop-trace-logs> + +<stop-trace-logs> stops creating the trace log file + +##### Notification: + +<trace-log-generated> notifies that O-RU<sub>8</sub> controller trace log file has been created, and carries Log filename. + +#### A3.12.3.2 Procedure requirements + +(1) The O-RU<sub>8</sub> is triggered with <start-trace-logs> to start collecting trace logs, and the O-RU<sub>8</sub> replies rpc-reply to indicate whether the operation is successful. + +(2) The O-RU<sub>8</sub> starts to create log files in a loop and issues a <trace-log-generated> notification, and the URL includes all created Log files. + +(3) When the O-RU<sub>8</sub> controller needs to stop collecting the trace logs, it issues <stop-trace-logs>. The O-RU<sub>8</sub> immediately stops collecting the trace logs after receiving the <stop-trace-logs>, and indicates in rpc-reply that is-notification-last is TRUE. + +![Sequence diagram illustrating the procedure of tracing log between NETCONF Server/(O-RU) and NETCONF Client.](cc5f774bbeb8c9f900e5f07479a79229_img.jpg) + +``` + +sequenceDiagram + participant Server as NETCONF Server/(O-RU) + participant Client as NETCONF Client + + Client->>Server: [1] <rpc> <start-trace-logs> + Note over Server: O-RU shall start collecting trace log. + Server->>Client: [2] <rpc-reply> <trace-status-grouping> + + loop [log files are generated] + Note over Server: O-RU completed to create part of trace log files. + Server->>Client: [3] <notification> <trace-log-generated> (URLs of log files that contain trace logs collected) + end + + Client->>Server: [4] <rpc> <stop-trace-logs> + Note over Server: O-RU shall stop collecting trace log. + Server->>Client: [5] <rpc-reply> <trace-status-grouping> + + Note over Server: O-RU completed to create last part of trace log files. + Server->>Client: [6] <notification> <trace-log-generated> (URLs of log files that contain trace logs collected and is-notification-last=TRUE) + +``` + +Sequence diagram illustrating the procedure of tracing log between NETCONF Server/(O-RU) and NETCONF Client. + +Figure Annex3- 26 Procedure of tracing log + +## A3.13Startup procedure + +This subsection describes a typical startup process for Option8 O-RU<sub>8</sub>, with following main differences from 7-2x: + +1. CPRI L1 and L2 connections may be established in two main ways, default matching and self-adaption. The Option8 O-RU<sub>8</sub> supports line rates of 10137.6Mbps and 24330.24Mbps in the currently discussed context. The currently selected deployment mode is that the O-RU<sub>8</sub> and its superior CPRI device are matched by default (optical or electrical aspect, rate and error correcting code option, etc.) and are directly connectable, i.e., no CPRI link self-adaptive function is introduced in the current period. The self-adaptive function will be discussed later. + +2. CPRI clock does not require additional configurations for locking, but only needs to be monitored by alarms. Therefore, there is no clock synchronization attempt or configuration process in the startup procedure. + +3. Considering the convenience of device management in configuration scenarios without carrier, the alarm management is placed in front of U-plane configuration. + +4. Topology discovery is a behavior of CPRI Master, and O-RU<sub>8</sub> cascade scenario is not considered in the current period, it is not necessary to pay attention to it in the O-RU<sub>8</sub> context. + +### A3.13.1 Examples of O-RU<sub>8</sub> startup procedure + +**Table Annex3- 20 Option8 O-RU<sub>8</sub> startup procedure** + +| Startup procedure | Description | Reference chapter | +|--------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------| +| Initialization of the O-RU <sub>8</sub> northbound CPRI port | <p>The CPRI link synchronization involves: rate (matching to determine the encoding format), error correcting code, and P-value selection.</p> <p>Once the above parameters are determined, the O-RU<sub>8</sub> can perform data interaction with the outside world at the MAC layer if the physical links and the upstream devices are normal. The following mode may be chose herein:</p> <p>Mode 1:</p> <p>O-RU<sub>8</sub> matches by default with the upstream device in options such as rate and error correcting code, which is directly connectable.</p> <p>Mode 2:</p> <p>By introducing self-adaption, and the O-RU<sub>8</sub> interacts with the upstream device, and each matches with an appropriate rate and error correcting code options according to a predetermined adaptation action; the P-value is extracted from the CPRI control word.</p> <p>Note: O-RU<sub>8</sub> provides a globally unique MAC address for each CPRI uplink port</p> | none | + +| | | | +|--------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------| +| Initialization of the M-plane network layer connection | By DHCP, O-RU <sub>8</sub> obtains its own M-plane IP address as the basis for external interaction | Chapter 4.2.3 | +| M-plane Call Home | O-RU <sub>8</sub> initiates NETCONF Call Home to O-DU <sub>8</sub> | Chapter 4.2.4.1 | +| establishing SSH connection | O-DU <sub>8</sub> establish SSH connections with O-RU <sub>8</sub> ;<br>performing NETCONF certification | Chapter 4.2.4 | +| NETCONF capacity discovery | performing NETCONF capacity discovery by O-RU <sub>8</sub> and O-DU <sub>8</sub> | Chapter 4.2.5 | +| NETCONF connection monitoring | performing NETCONF connection monitoring by O-RU <sub>8</sub> and O-DU <sub>8</sub> | Chapter 4.2.5 | +| Read O-RU <sub>8</sub> parameter | obtaining O-RU <sub>8</sub> parameter | | +| O-RU <sub>8</sub> software management | O-DU <sub>8</sub> verifies and manages the O-RU <sub>8</sub> software, ensures that the O-RU <sub>8</sub> software is as expected | Chapter 4.4 | +| O-RU <sub>8</sub> fault management | Initializing O-RU <sub>8</sub> fault management to achieve state control of the O-RU <sub>8</sub> .<br><br>Note: Fault management is placed in front of the U-plane configuration so that the fault management of O-RU <sub>8</sub> can be performed normally even when there is no cell configuration. | Chapter 4.5 | +| O-RU <sub>8</sub> U-plane management | Carrier antenna | Chapter 4.8.4 | +| Delay configuration | Delay configuration | Chapter 4.9.4 | +| Carrier status management | Carrier status management | Chapter 4.8.5 | +| Fault management supplement | Supplementing corresponding fault management arrangement after the carrier being activated | Chapter 4.5 | + +![Flowchart of O-RU startup procedure showing steps from NETCONF Server/Client interaction to service availability.](2b27456baf618a836f786933758e062d_img.jpg) + +``` + +graph TD + subgraph Top + NS1[NETCONF Server] + NC1[NETCONF Client] + end + + PC[Pre-condition: initialization of O-RU northbound CPRI interface is completed] + + subgraph MPlane [Creating and initializing of M-plane connection] + direction TB + M1{{Initializing M-plane network layer connection}} + M2{{M-plane CALL HOME}} + M3{{Establishing M-plane SSH connection}} + M4{{Reading M-plane NETCONF capacity set}} + M5{{Keeping M-plane NETCONF connection alive}} + M6{{Reading O-RU parameters}} + end + + SM[Software management] + IFM[Initializing fault management] + + subgraph Config [Sharing cell and U-plane configurations] + direction TB + C1{{O-RU U-plane configuration}} + C2{{Delay configuration}} + C3{{Carrier state management}} + C4{{Fault management supplement}} + end + + SA[Service available] + + subgraph Bottom + NS2[NETCONF Server] + NC2[NETCONF Client] + end + + NS1 -.-> NC1 + NS2 -.-> NC2 + PC -.-> MPlane + MPlane --> SM + SM --> IFM + IFM --> Config + Config --> SA + SA -.-> NS2 + SA -.-> NC2 + +``` + +The diagram illustrates the O-RU startup procedure. It begins with a pre-condition: initialization of O-RU northbound CPRI interface is completed. The process then enters a phase for creating and initializing the M-plane connection, which includes steps like initializing the network layer connection, calling home, establishing an SSH connection, reading capacity sets, keeping the connection alive, and reading O-RU parameters. This is followed by software management and initializing fault management. The next phase is sharing cell and U-plane configurations, including O-RU U-plane configuration, delay configuration, carrier state management, and fault management supplement. Finally, the service becomes available, and the process concludes with the NETCONF Server and Client. + +Flowchart of O-RU startup procedure showing steps from NETCONF Server/Client interaction to service availability. + +Figure Annex3- 27 Examples of O-RU<sub>s</sub> startup procedure + +## A3.14 Appendix - YANG Model Tree Diagram + +This appendix lists YANG model tree diagrams that are newly defined or modified by this specification; refer to the O-RAN specification for other YANG models. + +### A3.14.1 A.1 o-ran-uplane-conf-option8 Module + +The format for the uplane conf option8 module is provided below + +``` + +module: o-ran-uplane-conf-option8 + + +--rw user-plane-configuration + + +--rw tx-links* [name] + | +--rw name string + | +--rw processing-element -> /o-ran-pe:processing-elements/ru-elements/name + | +--rw tx-array-carrier -> /user-plane-configuration/tx-array-carriers/name + | +--rw tx-endpoint -> /user-plane-configuration/tx-endpoints/name + +--rw rx-links* [name] + | +--rw name string + | +--rw processing-element -> /o-ran-pe:processing-elements/ru-elements/name + | +--rw rx-array-carrier -> /user-plane-configuration/rx-array-carriers/name + | +--rw rx-endpoint -> /user-plane-configuration/rx-endpoints/name + +--ro endpoint-types-option8* [id] + | +--ro id uint16 + +--ro static-tx-endpoints* [name] + | +--ro name string + | +--ro restricted-interfaces* -> /if:interfaces/interface/name + | +--ro array -> /user-plane-configuration/tx-arrays/name + | +--ro endpoint-type? -> ../endpoint-types-option8/id + +--ro static-rx-endpoints* [name] + | +--ro name string + +``` + +``` + +1 | +-ro restricted-interfaces* -> /if:interfaces/interface/name +2 | +-ro array -> /user-plane-configuration/rx-arrays/name +3 | +-ro endpoint-type? -> ../endpoint-types-option8/id +4 +-rw tx-endpoints* [name] +5 | +-rw name -> /user-plane-configuration/static-tx-endpoints/name +6 | +-rw compression! +7 | +-rw e-axcid +8 | +-rw o-du-port-bitmask uint16 +9 | +-rw band-sector-bitmask uint16 +10 | +-rw ccid-bitmask uint16 +11 | +-rw ru-port-bitmask uint16 +12 | +-rw eaxc-id uint16 +13 +-rw rx-endpoints* [name] +14 | +-rw name -> /user-plane-configuration/static-rx-endpoints/name +15 | +-rw compression +16 | +-rw e-axcid +17 | | +-rw o-du-port-bitmask uint16 +18 | | +-rw band-sector-bitmask uint16 +19 | | +-rw ccid-bitmask uint16 +20 | | +-rw ru-port-bitmask uint16 +21 | | +-rw eaxc-id uint16 +22 | +-rw non-time-managed-delay-enabled? boolean +23 +-rw tx-array-carriers* [name] +24 | +-rw name string +25 | +-rw absolute-frequency-center uint32 +26 | +-rw center-of-channel-bandwidth uint64 +27 | +-rw channel-bandwidth uint64 + +``` + +``` + +1 | +-rw active? enumeration +2 | +-ro state enumeration +3 | +-rw type? enumeration +4 | +-ro duplex-scheme? enumeration +5 | +-rw rw-duplex-scheme? -> /user-plane-configuration/tx-array-carriers[name=current()../name]/duplex-scheme +6 | +-rw rw-type? -> /user-plane-configuration/tx-array-carriers[name=current()../name]/type +7 | +-rw band-number? -> /mcap:module-capability/band-capabilities/band-number {mcap:LAA}? +8 | +-rw lte-tdd-frame +9 | | +-rw subframe-assignment enumeration +10 | | +-rw special-subframe-pattern enumeration +11 | +-rw gain decimal64 +12 | +-rw downlink-radio-frame-offset uint32 +13 | +-rw downlink-sfn-offset int16 +14 +-rw rx-array-carriers* [name] +15 | +-rw name string +16 | +-rw absolute-frequency-center uint32 +17 | +-rw center-of-channel-bandwidth uint64 +18 | +-rw channel-bandwidth uint64 +19 | +-rw active? enumeration +20 | +-ro state enumeration +21 | +-rw type? enumeration +22 | +-ro duplex-scheme? enumeration +23 | +-rw downlink-radio-frame-offset uint32 +24 | +-rw downlink-sfn-offset int16 +25 | +-rw gain-correction decimal64 +26 | +-rw n-ta-offset uint32 +27 +-ro tx-arrays* [name] + +``` + +``` + +| +-ro name string +| +-ro number-of-rows uint16 +| +-ro number-of-columns uint16 +| +-ro number-of-array-layers uint8 +| +-ro horizontal-spacing? decimal64 +| +-ro vertical-spacing? decimal64 +| +-ro normal-vector-direction +| | +-ro azimuth-angle? decimal64 +| | +-ro zenith-angle? decimal64 +| +-ro leftmost-bottom-array-element-position +| | +-ro x? decimal64 +| | +-ro y? decimal64 +| | +-ro z? decimal64 +| +-ro polarisations* [p] +| | +-ro p uint8 +| | +-ro polarisation polarisation_type +| +-ro band-number -> /mcap:module-capability/band-capabilities/band-number +| +-ro max-gain decimal64 +| +-ro independent-power-budget boolean +| +-ro capabilities* [] +| +-ro max-supported-frequency-dl? uint64 +| +-ro min-supported-frequency-dl? uint64 +| +-ro max-supported-bandwidth-dl? uint64 +| +-ro max-num-carriers-dl? uint32 +| +-ro max-carrier-bandwidth-dl? uint64 +| +-ro min-carrier-bandwidth-dl? uint64 +| +-ro supported-technology-dl* enumeration + +``` + +``` + +1 +-ro rx-arrays* [name] +2 | +-ro name string +3 | +-ro number-of-rows uint16 +4 | +-ro number-of-columns uint16 +5 | +-ro number-of-array-layers uint8 +6 | +-ro horizontal-spacing? decimal64 +7 | +-ro vertical-spacing? decimal64 +8 | +-ro normal-vector-direction +9 | | +-ro azimuth-angle? decimal64 +10 | | +-ro zenith-angle? decimal64 +11 | +-ro leftmost-bottom-array-element-position +12 | | +-ro x? decimal64 +13 | | +-ro y? decimal64 +14 | | +-ro z? decimal64 +15 | +-ro polarisations* [p] +16 | | +-ro p uint8 +17 | | +-ro polarisation polarisation_type +18 | +-ro band-number -> /mcap:module-capability/band-capabilities/band-number +19 | +-ro gain-correction-range +20 | | +-ro max decimal64 +21 | | +-ro min decimal64 +22 | +-ro capabilities* [] +23 | +-ro max-supported-frequency-ul? uint64 +24 | +-ro min-supported-frequency-ul? uint64 +25 | +-ro max-supported-bandwidth-ul? uint64 +26 | +-ro max-num-carriers-ul? uint32 +27 | +-ro max-carrier-bandwidth-ul? uint64 + +``` + +``` + +1 | +-ro min-carrier-bandwidth-ul? uint64 +2 | +-ro supported-technology-ul* enumeration +3 +-ro relations* [entity] +4 | +-ro entity uint16 +5 | +-ro array1 +6 | | +-ro (antenna-type)? +7 | | +-:(tx) +8 | | | +-ro tx-array-name? -> /o-ran-uplane-conf:user-plane-configuration/tx-arrays/name +9 | | +-:(rx) +10 | | +-ro rx-array-name? -> /o-ran-uplane-conf:user-plane-configuration/rx-arrays/name +11 | +-ro array2 +12 | | +-ro (antenna-type)? +13 | | +-:(tx) +14 | | | +-ro tx-array-name? -> /o-ran-uplane-conf:user-plane-configuration/tx-arrays/name +15 | | +-:(rx) +16 | | +-ro rx-array-name? -> /o-ran-uplane-conf:user-plane-configuration/rx-arrays/name +17 | +-ro types* [relation-type] +18 | +-ro relation-type enumeration +19 | +-ro pairs* [element-array1] +20 | +-ro element-array1 uint16 +21 | +-ro element-array2? uint16 +22 +-rw eaxc-id-group-configuration {mcap:EAXC-ID-GROUP-SUPPORTED}? +23 +-rw max-num-tx-eaxc-id-groups? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-tx-eaxc-id-groups +24 +-rw max-num-tx-eaxc-ids-per-group? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-tx-eaxc-ids-per- +25 group +26 +-rw max-num-rx-eaxc-id-groups? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-rx-eaxc-id-groups +27 +-rw max-num-rx-eaxc-ids-per-group? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-rx-eaxc-ids-per- +28 group + +``` + +``` + + +-rw tx-eaxc-id-group* [representative-tx-eaxc-id] + + | +-rw representative-tx-eaxc-id uint16 + + | +-rw member-tx-eaxc-id* uint16 + + +-rw rx-eaxc-id-group* [representative-rx-eaxc-id] + + | +-rw representative-rx-eaxc-id uint16 + + | +-rw member-rx-eaxc-id* uint16 + + + + notifications: + + +---n tx-array-carriers-state-change + + | +-ro tx-array-carriers* [name] + + | +-ro name -> /user-plane-configuration/tx-array-carriers/name + + | +-ro state? -> /user-plane-configuration/tx-array-carriers/state + + +---n rx-array-carriers-state-change + + | +-ro rx-array-carriers* [name] + + | +-ro name -> /user-plane-configuration/rx-array-carriers/name + + | +-ro state? -> /user-plane-configuration/rx-array-carriers/state + +``` + +### A3.14.2 A.2. o-ran-uplane-conf-hub Module + +``` + + module: o-ran-uplane-conf-hub + + +-rw eaxc-id-group-configuration {mcap:EAXC-ID-GROUP-SUPPORTED}? + + | +-rw max-num-tx-eaxc-id-groups? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-tx-eaxc-id-groups + + | +-rw max-num-tx-eaxc-ids-per-group? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-tx-eaxc-ids-per-group + + | +-rw max-num-rx-eaxc-id-groups? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-rx-eaxc-id-groups + + | +-rw max-num-rx-eaxc-ids-per-group? -> /mcap:module-capability/ru-capabilities/eaxcid-grouping-capabilities/max-num-rx-eaxc-ids-per-group + + | +-rw tx-eaxc-id-group* [representative-tx-eaxc-id] + + | | +-rw representative-tx-eaxc-id uint16 + +``` + +``` + +| | +-rw member-tx-eaxc-id* uint16 +| +-rw rx-eaxc-id-group* [representative-rx-eaxc-id] +| +-rw representative-rx-eaxc-id uint16 +| +-rw member-rx-eaxc-id* uint16 ++-rw user-plane-configuration + +-rw low-level-tx-links* [name] + | +-rw name string + | +-rw processing-element -> /o-ran-pe:processing-elements/ru-elements/name + | +-rw low-level-tx-endpoint -> /user-plane-configuration/low-level-tx-endpoints/name + +-rw low-level-rx-links* [name] + | +-rw name string + | +-rw processing-element -> /o-ran-pe:processing-elements/ru-elements/name + | +-rw low-level-rx-endpoint -> /user-plane-configuration/low-level-rx-endpoints/name + | +-rw user-plane-uplink-marking? -> /o-ran-pe:processing-elements/enhanced-uplane-mapping/uplane-mapping/up-marking-name + +-ro endpoint-types* [id] + +-ro id uint16 + +-ro supported-section-types* [section-type] + | +-ro section-type uint8 + | +-ro supported-section-extensions* uint8 + +-ro supported-frame-structures* uint8 + +-ro managed-delay-support? enumeration + +-ro multiple-numerology-supported? boolean + +-ro max-numerology-change-duration? uint16 + +-ro max-control-sections-per-data-section? uint8 + +-ro max-sections-per-symbol? uint16 + +-ro max-sections-per-slot? uint16 + +-ro max-remasks-per-section-id? uint8 + +``` + +``` + +1 | +-ro max-beams-per-symbol? uint16 +2 | +-ro max-beams-per-slot? uint16 +3 | +-ro max-prb-per-symbol? uint16 +4 | +-ro prb-capacity-allocation-granularity* uint16 +5 | +-ro max-numerologies-per-symbol? uint16 +6 +-ro endpoint-capacity-sharing-groups* [id] +7 | +-ro id uint16 +8 | +-ro max-control-sections-per-data-section? uint8 +9 | +-ro max-sections-per-symbol? uint16 +10 | +-ro max-sections-per-slot? uint16 +11 | +-ro max-remasks-per-section-id? uint8 +12 | +-ro max-beams-per-symbol? uint16 +13 | +-ro max-beams-per-slot? uint16 +14 | +-ro max-prb-per-symbol? uint16 +15 | +-ro max-numerologies-per-symbol? uint16 +16 | +-ro max-endpoints? uint16 +17 | +-ro max-managed-delay-endpoints? uint16 +18 | +-ro max-non-managed-delay-endpoints? uint16 +19 +-ro endpoint-prach-group* [id] +20 | +-ro id uint16 +21 | +-ro supported-prach-preamble-formats* prach-preamble-format +22 +-ro static-low-level-tx-endpoints* [name] +23 | +-ro name string +24 | +-ro restricted-interfaces* -> /if:interfaces/interface/name +25 | +-ro endpoint-type? -> ../endpoint-types/id +26 | +-ro capacity-sharing-groups* -> ../endpoint-capacity-sharing-groups/id +27 +-ro static-low-level-rx-endpoints* [name] + +``` + +``` + +1 | +-ro name string +2 | +-ro restricted-interfaces* -> /if:interfaces/interface/name +3 | +-ro endpoint-type? -> ../endpoint-types/id +4 | +-ro capacity-sharing-groups* -> ../endpoint-capacity-sharing-groups/id +5 | +-ro prach-group? -> ../endpoint-prach-group/id +6 +-rw low-level-tx-endpoints* [name] +7 | +-rw name -> /user-plane-configuration/static-low-level-tx-endpoints/name +8 | +-rw compression! +9 | | +-rw iq-bitwidth? uint8 +10 | | +-rw compression-type enumeration +11 | | x--rw bitwidth? uint8 +12 | | +-rw (compression-format)? +13 | | +--:(no-compresison) +14 | | +--:(block-floating-point) +15 | | | +-rw exponent? uint8 +16 | | | +--:(block-floating-point-selective-re-sending) +17 | | | +-rw sres-exponent? uint8 +18 | | | +--:(block-scaling) +19 | | | +-rw block-scalar? uint8 +20 | | | +--:(u-law) +21 | | | +-rw comp-bit-width? uint8 +22 | | | +-rw comp-shift? uint8 +23 | | | +--:(beam-space-compression) +24 | | | +-rw active-beam-space-coeficient-mask* uint8 +25 | | | +-rw block-scaler? uint8 +26 | | | +--:(modulation-compression) +27 | | | +-rw csf? uint8 + +``` + +``` + +1 | | | +--rw mod-comp-scaler? uint16 +2 | | +--:(modulation-compression-selective-re-sending) +3 | | +--rw sres-csf? uint8 +4 | | +--rw sres-mod-comp-scaler? uint16 +5 | +--rw frame-structure? uint8 +6 | +--rw cp-type? enumeration +7 | +--rw cp-length uint16 +8 | +--rw cp-length-other uint16 +9 | +--rw offset-to-absolute-frequency-center int32 +10 | +--rw number-of-prb-per-scs* [scs] +11 | | +--rw scs mcap:scs-config-type +12 | | +--rw number-of-prb uint16 +13 | | +--rw e-axcid +14 | | +--rw o-du-port-bitmask uint16 +15 | | +--rw band-sector-bitmask uint16 +16 | | +--rw ccid-bitmask uint16 +17 | | +--rw ru-port-bitmask uint16 +18 | | +--rw eaxc-id uint16 +19 | +--rw downlink-radio-frame-offset uint32 +20 | +--rw downlink-sfn-offset int16 +21 +--rw low-level-rx-endpoints* [name] +22 | +--rw name -> /user-plane-configuration/static-low-level-rx-endpoints/name +23 | +--rw compression +24 | | +--rw iq-bitwidth? uint8 +25 | | +--rw compression-type enumeration +26 | | x--rw bitwidth? uint8 +27 | | +--rw (compression-format)? + +``` + +| | | | +|----|---------------------------------------------------|----------------------| +| 1 | +--:(no-compresison) | | +| 2 | +--:(block-floating-point) | | +| 3 | +--rw exponent? | uint8 | +| 4 | +--:(block-floating-point-selective-re-sending) | | +| 5 | +--rw sres-exponent? | uint8 | +| 6 | +--:(block-scaling) | | +| 7 | +--rw block-scalar? | uint8 | +| 8 | +--:(u-law) | | +| 9 | +--rw comp-bit-width? | uint8 | +| 10 | +--rw comp-shift? | uint8 | +| 11 | +--:(beam-space-compression) | | +| 12 | +--rw active-beam-space-coeficient-mask* | uint8 | +| 13 | +--rw block-scaler? | uint8 | +| 14 | +--:(modulation-compression) | | +| 15 | +--rw csf? | uint8 | +| 16 | +--rw mod-comp-scaler? | uint16 | +| 17 | +--:(modulation-compression-selective-re-sending) | | +| 18 | +--rw sres-csf? | uint8 | +| 19 | +--rw sres-mod-comp-scaler? | uint16 | +| 20 | +--rw frame-structure? | uint8 | +| 21 | +--rw cp-type? | enumeration | +| 22 | +--rw cp-length | uint16 | +| 23 | +--rw cp-length-other | uint16 | +| 24 | +--rw offset-to-absolute-frequency-center | int32 | +| 25 | +--rw number-of-prb-per-scs* [scs] | | +| 26 | +--rw scs | mcap:scs-config-type | +| 27 | +--rw number-of-prb | uint16 | + +``` + +1 | +-rw ul-fft-sampling-offsets* [scs] +2 | | +-rw scs mcap:scs-config-type +3 | | +-rw ul-fft-sampling-offset? uint16 +4 | +-rw e-axcid +5 | | +-rw o-du-port-bitmask uint16 +6 | | +-rw band-sector-bitmask uint16 +7 | | +-rw ccid-bitmask uint16 +8 | | +-rw ru-port-bitmask uint16 +9 | | +-rw eaxc-id uint16 +10 | +-rw non-time-managed-delay-enabled? boolean +11 | +-rw downlink-radio-frame-offset uint32 +12 | +-rw downlink-sfn-offset int16 +13 | +-rw n-ta-offset uint32 +14 +-rw general-config +15 +-rw regularization-factor-se-configured? boolean +16 +-rw little-endian-byte-order? boolean + +``` + +### A3.14.3 A.3. o-ran-shared-cell-ecpri7-to-cpri8 Module + +``` + +18 module: o-ran-shared-cell-ecpri7-to-cpri8 +19 +-rw shared-cell-cpri7-to-cpri8 +20 +-ro shared-cell-module-cap-ecpri7-to-cpri8 +21 | +-ro max-number-node-copy-and-combine uint8 +22 | +-ro max-number-eaxcid-copy uint8 +23 | +-ro max-number-eaxcid-combine uint8 +24 | +-ro compression-method-supported* [] {FHM-eCPRI7-to-CPRI8}? +25 +-rw shared-cell-config +26 +-rw (shared-cell-copy-combine-mode)? +27 +--:(COMMON) + +``` + +``` + +1 | +--rw shared-cell-copy-entities* [name] +2 +3 | | +--rw name string +4 +5 | | +--rw north-node-processing-element? -> /o-ran-pe:processing-elements/ru-elements/name +6 +7 | | +--rw south-node-processing-elements* -> /o-ran-pe:processing-elements/ru-elements/name +8 +9 | | +--rw shared-cell-copy-uplane-config {FHM}? +10 +11 | | +--rw tx-eaxc-id* [eaxc-id] +12 +13 | | | +--rw eaxc-id uint16 +14 +15 | | +--rw rx-eaxc-id* [eaxc-id] +16 +17 | | | +--rw eaxc-id uint16 +18 +19 | | +--rw downlink-radio-frame-offset uint32 +20 +21 | | +--rw downlink-sfn-offset int16 +22 +23 | +--rw shared-cell-combine-entities* [name] +24 +25 | +--rw name string +26 +27 | +--rw north-node-processing-element? -> /o-ran-pe:processing-elements/ru-elements/name +28 +29 | +--rw south-node-processing-elements* -> /o-ran-pe:processing-elements/ru-elements/name +30 +31 | +--rw ta3-prime-max? uint32 +32 +33 | +--rw shared-cell-combine-uplane-config {FHM}? +34 +35 | +--rw rx-eaxc-id* [eaxc-id] +36 +37 | | +--rw eaxc-id uint16 +38 +39 | | +--rw compression-method +40 +41 | | +--rw iq-bitwidth? uint8 +42 +43 | | +--rw compression-type enumeration +44 +45 | | x--rw bitwidth? uint8 +46 +47 | | +--rw (compression-format)? +48 +49 | | +--:(no-compression) +50 +51 | | +--:(block-floating-point) +52 +53 | | | +--rw exponent? uint8 + +``` + +``` + +1 | | +--:(block-floating-point-selective-re-sending) +2 | | | +--rw sres-exponent? uint8 +3 | | +--:(block-scaling) +4 | | | +--rw block-scalar? uint8 +5 | | +--:(u-law) +6 | | | +--rw comp-bit-width? uint8 +7 | | | +--rw comp-shift? uint8 +8 | | +--:(beam-space-compression) +9 | | | +--rw active-beam-space-coeficient-mask* uint8 +10 | | | +--rw block-scaler? uint8 +11 | | +--:(modulation-compression) +12 | | | +--rw csf? uint8 +13 | | | +--rw mod-comp-scaler? uint16 +14 | | +--:(modulation-compression-selective-re-sending) +15 | | +--rw sres-csf? uint8 +16 | | +--rw sres-mod-comp-scaler? uint16 +17 | +--rw downlink-radio-frame-offset uint32 +18 | +--rw downlink-sfn-offset int16 +19 | +--rw n-ta-offset uint32 +20 | +--rw number-of-prb uint16 +21 +--:(SELECTIVE) +22 +23 augment /sc:shared-cell/sc:shared-cell-config/sc:shared-cell-copy-combine-mode: +24 +--:(eCPRI7-to-CPRI8) +25 +--rw shared-cell-copy-entities-ecpri7-to-cpri8* [name] +26 | +--rw name string +27 | +--rw low-level-tx-endpoint? -> /uc-hub:user-plane-configuration/low-level-tx-endpoints/name + +``` + +``` + +| +--rw south-node-processing-elements-cpri* -> /o-ran-pe:processing-elements/ru-elements/name ++--rw shared-cell-combine-entities-ecpri7-to-cpri8* [name] + +--rw name string + +--rw low-level-rx-endpoint? -> /uc-hub:user-plane-configuration/low-level-tx-endpoints/name + +--rw south-node-processing-elements-cpri* -> /o-ran-pe:processing-elements/ru-elements/name + +``` + +### A3.14.4 A.4 o-ran-interfaces-cpri Module + +``` + +module: o-ran-interfaces-cpri + ++--ro cpri-status + ++--ro cpri-startup-status + +| +--ro cpri-startup-state? enumeration + ++--ro cpri-link-status + + +--ro cpri-link-state? enumeration + +augment /if:interfaces/if:interface: + ++--rw cpri-interface + + +--rw mac-address? yang:mac-address + + +--rw port-reference + + | +--rw port-name? -> /hw:hardware/component/name + + | +--rw port-number? uint8 + + | +--rw cpri-config {CPRI-INTERFACE}? + + | +--rw port-mode? enumeration {CPRI-INTERFACE}? + + | +--rw cpri-version? string + + | +--rw line-bit-rate? decimal64 + + | +--rw ethernet-pointer? uint8 + + | +--rw samplewidth? uint8 + + | +--rw linecoding? enumeration + + +--ro ber-counts? string + +``` + +``` + +rpcs: + ++---x reset-interface-counters + +notifications: + ++---n cpri-startup-state-change + +| +--ro cpri-startup-state? -> /cpri-status/cpri-startup-status/cpri-startup-state + ++---n cpri-link-state-change + ++--ro cpri-link-state? -> /cpri-status/cpri-link-status/cpri-link-state + +``` + +### A3.14.5 A.5 o-ran-processing-element-cpri Module + +``` + +module: o-ran-processing-element-cpri + +augment /o-ran-pe:processing-elements/o-ran-pe:ru-elements/o-ran-pe:transport-flow: + ++--rw cpri-flow + ++--rw compression-flag? boolean + ++--rw iq-start-bit? uint16 + ++--rw iq-end-bit? uint16 + ++--rw inband-compression-start-bit? uint16 + ++--rw inband-compression-end-bit? uint16 + ++--rw agc-start-bit? uint16 + ++--rw agc-end-bit? uint16 + +``` + +### A3.14.6 A.6 o-ran-delay-management-ru-cpri Module + +``` + +module: o-ran-delay-management-ru-cpri + ++--r ru-delay-profile + ++--r ru-delay-profile-list-radio-related + +``` + +``` + ++--ru-delay-profile-common ++--rw ru-delay-config-cpri-link-related ++--rw ru-delay-config-data-flow-related + +``` + +### A3.14.7 A.7. o-ran-system-time Module + +``` + +module: o-ran-system-time + + +--rw system-time + +--rw current-datetime? ietf-yang-types:date-and-time + +``` + +### A3.14.8 A.8. o-ran-sync-cpri Module + +``` + +module: o-ran-sync-cpri + + +--rw sync-status + | +--rw reporting-period? uint32 + | +--ro sync-state? enumeration + | +--ro error-message? string + | +--ro source-port-number? -> if:interfaces/interface/o-ran-int-cpri:cpri-interface/port-reference/port-number + + notifications: + +---n cpri-state-change + +--ro cpri-sync-state? -> /sync-status/sync-state + +``` + +# --- Annex ZZZ O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributors; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an O-RAN + +Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non- Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of ORAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER + +PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED “AS IS” WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance’s sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity’s or association’s agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates’ performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +1 By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, +2 or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this +3 Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, +4 Contributors or Academic Contributors. + +5 In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, +6 void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken +7 from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in +8 full force and effect. + +9 \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/0861f4d49a1a30627755a25e617fb965_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/0861f4d49a1a30627755a25e617fb965_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..77f9d18a894cb50f5931a435cce925421e0bccc9 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/0861f4d49a1a30627755a25e617fb965_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6021576b4370579f35a7443abd58ebde4ab794f552b9a7a5c5a3cec4c519d8ba +size 11265 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/0be0fe33eaa74ee33aeaf5f166c4c7be_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/0be0fe33eaa74ee33aeaf5f166c4c7be_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d744a00ffc311c454fb14edd08de9fb90e4bf16d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/0be0fe33eaa74ee33aeaf5f166c4c7be_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64bc6ce7e594a0e451dc13ea9e579fb17572b20e2ce271981cd264a9a7a8b38b +size 30790 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/0cd924708b2ae29bc0557ff6e593fd1a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/0cd924708b2ae29bc0557ff6e593fd1a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd5fb0a321b4684a58a88c26355dd73bd1ebd56f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/0cd924708b2ae29bc0557ff6e593fd1a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fe41d7173d4d95b408b41990b4d1631c78e1275485a697dc19cd936bf982a895 +size 27692 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/199faf8ef34333df14621bc64dffcf2f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/199faf8ef34333df14621bc64dffcf2f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..691a2097ad24dadfbad3ad61c82d086e9d65b4dd --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/199faf8ef34333df14621bc64dffcf2f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4b505dd2ddaa6111f4a4084150fd8fa3cdde5c4e3ed51ea64acc99cb8fd8dbd8 +size 26501 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/1b77b866292c29500aa70de068e2564c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/1b77b866292c29500aa70de068e2564c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ba854f7e49a20b466008ab86d19268919bf3867c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/1b77b866292c29500aa70de068e2564c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f7b25c8c32b146ee3744620ff44248a8b70d0a17a63529e746a0d5db6b53aa4f +size 29855 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/1fe153834fb99e2540143383446ba2b2_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/1fe153834fb99e2540143383446ba2b2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ab813ce44320608649b94c96c58073c3cbb2a18b --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/1fe153834fb99e2540143383446ba2b2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b4785a0f5de4d0e3b3f8ec0cf260a73bf1efcabc594caae8cdbdefe5a9a70b3e +size 11969 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/25614ad1c396d94e47a6d30b1e8d647c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/25614ad1c396d94e47a6d30b1e8d647c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a58c4344d9a86dc665b8a607345fa41f7b120d8f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/25614ad1c396d94e47a6d30b1e8d647c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:18a28f65b7638e8c95991ad7940b45029ba7f5cbd1e2f47fbd764f7d071e9878 +size 17590 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/263a6ff571b360563a8e9c3b7a7a2408_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/263a6ff571b360563a8e9c3b7a7a2408_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..47a68a298e325c2933a10225d54051d1ec4d3e63 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/263a6ff571b360563a8e9c3b7a7a2408_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:38491fd19ec2e397b4953d6c01c3882df3842ab25348d2e36b04cddcd0746a7b +size 13216 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/274499c22c7c4434aab24ee5a84f5520_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/274499c22c7c4434aab24ee5a84f5520_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4db165238af6234a98cbd650550087137d654a93 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/274499c22c7c4434aab24ee5a84f5520_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1ef6d7f756ac5796185cfeda9db8489d24c4157d2e7e9c7185e06f4b30f29fa0 +size 29862 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/4275f575465b22f841bc69d647664755_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/4275f575465b22f841bc69d647664755_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ddd5a55b6df6d92cc69f2dff900f9a68f474d857 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/4275f575465b22f841bc69d647664755_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fad5044bb7e9995d23483a32e6a8baac9b85726946af2313b125a1656c0da281 +size 4495 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/44edac048e8bb02e806143a680b0cf5f_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/44edac048e8bb02e806143a680b0cf5f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a46022fa203435f9f5f33a2ab79e29373d95a576 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/44edac048e8bb02e806143a680b0cf5f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4f29028539a5e0682ec80d48c05b352d092c13d93d762dce83a668aa3f1040b3 +size 32325 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3a71b98fcfc274b0603208cc5e23601d7fc924a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/5b5c7bcc4dec47a10a19287c1fc817e6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84a0e505aa8e8fcec39c03736b466858a7c1ef91abe309cdd2974ee18257e23b +size 4531 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/65df3d7fd8c004a98402abbd4553913a_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/65df3d7fd8c004a98402abbd4553913a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..10be5e11d4c58c5be943cda35ba248ee5799c042 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/65df3d7fd8c004a98402abbd4553913a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9057d9adaf27df12c40486b4cecffba243e6a0fceec6758370e13f7fcd339ed +size 4526 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/722c23607a0502ed5793300e93bf6ebc_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/722c23607a0502ed5793300e93bf6ebc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..48bde9b6c12adfddd03385a223f7b2f00cd59924 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/722c23607a0502ed5793300e93bf6ebc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b89799a48977f62d8525092927f964dc64f15a07edd682eda36d0930761fc286 +size 17040 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/86a771f11fbc580d8fda7a877acd1c69_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/86a771f11fbc580d8fda7a877acd1c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82827af191c934857f3a5a97842fa19fb4aa5978 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/86a771f11fbc580d8fda7a877acd1c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54f690c723a011f67b244eeda5cca1f67e7a7784e122d72a637cea1ca968c8f4 +size 4531 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/a1ab6125810fa3c4ab752737a4106f2b_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/a1ab6125810fa3c4ab752737a4106f2b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b0eda1abb096fd626861aa261ac73f0b9fbec7e5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/a1ab6125810fa3c4ab752737a4106f2b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8b8c4019920ee5071cc6381992f107b6f1c6136486d3ed046015f661656919a6 +size 26654 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/b0144970146df9869f71fe11fe78802c_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/b0144970146df9869f71fe11fe78802c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c5fd72545bceea1c79b4dd2510cb56f68f0233f9 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/b0144970146df9869f71fe11fe78802c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cee8d75813b2ab4410c89ebba312cd21a0d6a4309df44bc2fb1811267dafe304 +size 9706 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/c1bc15cc1c93c930f668b9979c99952d_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/c1bc15cc1c93c930f668b9979c99952d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b9fdb5d4483155dcf5045b4adb409a04e1e24730 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/c1bc15cc1c93c930f668b9979c99952d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1a36d92dd3cdb88dfc7aeb1c462abd13de46f3cbf405724339367dcc72700366 +size 4566 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/c3931b4d9cf8eafccf7fc72885ab4ce3_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/c3931b4d9cf8eafccf7fc72885ab4ce3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8c669c26f9efdf8c8ca2f8a8bb5a823eaadbfb57 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/c3931b4d9cf8eafccf7fc72885ab4ce3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:752d8f61f26f7c5727ae31ffcb68a735009bb158e6897b0c859de0854baeaf69 +size 11301 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cde559ef2b243c238ff9009ad25a0e8d4338d2fd --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/ca784e3443ed577f5b753ffb73ef9ce9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf8f73f65f81cbe4fe1bba9775cbd4d69ed9febccfbfd336a178e41b2160bc76 +size 4531 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/cdf9ddce1aad69087b420b079427f1cf_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/cdf9ddce1aad69087b420b079427f1cf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3c8bde5b6bd7abcea2e0bd51503aa43bd7e749f2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/cdf9ddce1aad69087b420b079427f1cf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:21ad7a08081b299095b29b3ccd9a7d5d539a1ed32ebc823916797b93d5a9ce05 +size 28586 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/e0d5229175015257d7246b59516002eb_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/e0d5229175015257d7246b59516002eb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..03762d1f5beb2981f33702b275332efbc146aace --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/e0d5229175015257d7246b59516002eb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f762bf438d0d60df7599d866906e6bd44ab0959509baeba502f195bb2704d846 +size 23132 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/eb2185736d9e63adbfb0b2dcba475adf_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/eb2185736d9e63adbfb0b2dcba475adf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9095cd321356041892da78ccd30028f17bd512f2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/eb2185736d9e63adbfb0b2dcba475adf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0ace8e702320890d64419af11906390d69af651f3e831304b75416713c35c6fd +size 17167 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/f2bb3487433aa648cce6c444ac4cd814_img.jpg b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/f2bb3487433aa648cce6c444ac4cd814_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..375417ac10d355b5360e4bebff76a84bee6ede51 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/f2bb3487433aa648cce6c444ac4cd814_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7bbca6b8b01104e680f032b15934416000597648aced4b78ff42bcac87be36ab +size 11391 diff --git a/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/raw.md b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..4235e691226111e06d56e7039b94fbf5a8083c86 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.IPC-TEST.0-v01/raw.md @@ -0,0 +1,475 @@ + + +# --- **O-RAN Work Group 7 White-box Hardware Test Guidelines for Indoor Pico Cell** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +Register of Associations, Bonn VR 11238, VAT ID DE321720189 + +# --- Contents + +| | | +|-------------------------------------------------------------------------|----| +| List of figures ..... | 3 | +| List of tables ..... | 3 | +| Foreword..... | 4 | +| Modal verbs terminology ..... | 4 | +| 1 Scope ..... | 5 | +| 2 References ..... | 5 | +| 2.1 Normative references ..... | 5 | +| 2.2 Informative references ..... | 5 | +| 3 Definition of terms, symbols and abbreviations ..... | 6 | +| 3.1 Terms ..... | 6 | +| 3.2 Symbols..... | 6 | +| 3.3 Abbreviations ..... | 6 | +| 4 Test methodology and configuration ..... | 7 | +| 4.1 Hardware architecture ..... | 7 | +| 4.2 Test equipment and tools ..... | 8 | +| 4.3 Test configuration ..... | 8 | +| 5 O-CU and O-DU Tests ..... | 9 | +| 5.1 GNSS synchronization accuracy..... | 9 | +| 5.2 IEEE 1588v2 synchronization accuracy ..... | 10 | +| 5.3 Clock hold-over ability ..... | 11 | +| 5.4 Power supply method..... | 11 | +| 5.5 Dimension and volume ..... | 12 | +| 5.6 Cell capacity..... | 13 | +| 5.7 Power consumption..... | 14 | +| 6 O-RU Hardware Tests..... | 14 | +| 6.1 Operating frequency band, bandwidth and carrier configuration ..... | 14 | +| 6.2 TX power and RF power configuration ..... | 15 | +| 6.3 Number of RF channels ..... | 16 | +| 6.4 Weight, dimensions, and volume..... | 16 | +| 6.5 Power supply capability ..... | 17 | +| 6.6 Power consumption..... | 17 | +| 7 O-RU RF Tests..... | 18 | +| 7.1 Tx Power accuracy..... | 18 | +| 7.2 EVM..... | 18 | +| 7.3 ACLR..... | 19 | +| 7.4 Spurious emission ..... | 19 | +| 7.5 Reference sensitivity ..... | 20 | +| 7.6 ACS..... | 21 | +| 7.7 ICS ..... | 22 | +| 7.8 Anti-blocking ..... | 23 | + +# --- List of figures + +| | | +|----------------------------------------------------------------------------------------------------------------------|---| +| Figure 4.1-1: Indoor pico cell based on Option 7-2x (O-RU utilizing optical fiber with integrated power cable) ..... | 7 | +| Figure 4.1-2: Indoor pico cell based on Option 8 (O-RU utilizing CAT-6A cable) ..... | 8 | + +# --- List of tables + +| | | +|-------------------------------|---| +| Table 4.2-1: Test Tools ..... | 8 | +|-------------------------------|---| + +# --- Foreword + +This Technical Specification (TS) has been produced by WG7 of the O-RAN Alliance. + +The content of the present document is subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. +- yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. +- zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +## --- Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# --- 1 Scope + +The present document specifies the test methods for Indoor Pico Cell. It determines whether a WG7 White box hardware reference design conforms with its requirements as specified in its Hardware Architecture and Requirement specification (HAR). + +In the main body of this specification (in any “chapter”) the information contained therein is informative. + +It is noted that additional test cases may be required for a comprehensive testing, which will be considered in the future version of this document. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN WG1: O-RAN Architecture Description, v12.0, June 2024. +- [2] 3GPP TS 38.104, “NR; Base Station (BS) radio transmission and reception”. +- [3] 3GPP TS 38.113, “NR: Base Station (BS) Electromagnetic Compatibility (EMC)”. +- [4] 3GPP TS 38.141-1, “NR; Base Station (BS) conformance testing Part 1: Conducted conformance testing”. +- [5] O-RAN WG7: Deployment Scenarios and Base Station Classes, v4.0, October 2022. +- [6] O-RAN WG7: O-RAN Indoor Picocell Hardware Architecture and Requirement (FR1 Only) Specification, v2.0, February 2024. +- [7] O-RAN WG7: Hardware Reference Design Specification for Indoor Picocell (FR1) with Split Architecture Option 7-2, v3.0, October 2021. + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +- [i.1] 3GPP TR 21.905: “Vocabulary for 3GPP Specifications”. + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms [given in [i.1] and the following] apply: + +**Carrier Frequency:** Center frequency of the cell. + +**F1 interface:** The open interface between O-CU and O-DU defined by 3GPP TS 38.473. + +**Frequency Band:** A designated frequency range for the operation of the base station and the UE radios. 5G NR frequency bands are divided into two different frequency ranges: Frequency Range 1 (FR1) that mainly includes sub-6GHz frequency bands, some of which are bands traditionally used by previous standards but has been extended to cover potential new spectrum offerings from 410MHz to 7125MHz; Frequency Range 2 (FR2) that includes frequency bands from 24.25 GHz to 52.6 GHz. Bands in this millimeter wave range have shorter range but higher available bandwidth than bands in the FR1. + +**Frequency Range:** It refers to bandwidth defined by the frequency range within which the Base Station can be operated, defined by the band-pass filter of the BS; e.g., 3.4 – 3.8 GHz (400 MHz). + +**Occupied Bandwidth (OBW):** It refers to the bandwidth occupied by the base station when operated, defined by the sum of the active bandwidths of the band allocation(s) operated. As defined by 3GPP TS 34.121 section 5.8, occupied bandwidth is the bandwidth containing 99% of the total integrated power of the transmitted spectrum, centered on the assigned channel frequency. The bandwidth between the 0.5% power frequency points is the occupied bandwidth. + +**Instantaneous Bandwidth (IBW):** It refers to the bandwidth in which all frequency components can be simultaneously analyzed. It is defined by the frequency boundaries of the operating band(s). + +**Fronthaul Gateway (FHGW):** A fronthaul gateway is a physical entity that is located between a distributed unit and one or more radio units where it distributes, aggregates, and/or converts fronthaul protocols between the distributed unit and multiple radio units. + +**gNB:** A RAN node providing NR user plane and control plane protocol terminations towards the UE, and connected via the NG interface to the 5GC + +## 3.2 Symbols + +Void + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations [given in [i.1] and the following] apply: + +| | | +|------|---------------------------------------------------| +| ACLR | Adjacent Channel Leakage Ratio | +| ACS | Adjacent Channel Selectivity | +| EVM | Error Vector Magnitude | +| FHGW | Fronthaul Gateway | +| GNSS | Global Navigation Satellite System | +| GPS | Global Positioning System | +| ICS | In-channel Selectivity | +| IEEE | Institute of Electrical and Electronics Engineers | +| NR | New Radio | +| O-CU | O-RAN Centralized Unit as defined by O-RAN | +| O-DU | O-RAN Distributed Unit as defined by O-RAN | +| O-RU | O-RAN Radio Unit as defined by O-RAN | + +| | | +|-----|---------------------------------| +| PPS | Pulse per Second | +| QAM | Quadrature Amplitude Modulation | +| RF | Radio Frequency | +| RX | Receiver | +| TX | Transmitter | + +# 4 Test methodology and configuration + +## 4.1 Hardware architecture + +Indoor picocell based on Option 7-2x and Option 8 consists of O-RU, O-DU, and FHGW. + +![Figure 4.1-1: Indoor pico cell based on Option 7-2x (O-RU utilizing optical fiber with integrated power cable). The diagram shows the hardware architecture. An O-CU/O-DU block is connected via red lines (Fiber) to two FHGW blocks. Each FHGW block is connected to multiple O-RU blocks. The connections between FHGW and O-RU are marked with yellow dots, indicating 'Fiber with power cable'. A legend at the bottom shows a red dot for 'Fiber' and a yellow dot for 'Fiber with power cable'.](274499c22c7c4434aab24ee5a84f5520_img.jpg) + +Figure 4.1-1: Indoor pico cell based on Option 7-2x (O-RU utilizing optical fiber with integrated power cable). The diagram shows the hardware architecture. An O-CU/O-DU block is connected via red lines (Fiber) to two FHGW blocks. Each FHGW block is connected to multiple O-RU blocks. The connections between FHGW and O-RU are marked with yellow dots, indicating 'Fiber with power cable'. A legend at the bottom shows a red dot for 'Fiber' and a yellow dot for 'Fiber with power cable'. + +**Figure 4.1-1: Indoor pico cell based on Option 7-2x (O-RU utilizing optical fiber with integrated power cable)** + +![Figure 4.1-2: Indoor pico cell based on Option 8 (O-RU utilizing CAT-6A cable). The diagram shows an O-CU/O-DU connected via fiber to two FHGWs. One FHGW is connected to three O-RUs via CAT-6A cables. The other FHGW is connected to one O-RU via CAT-6A cables. A legend indicates that red lines with dots represent Fiber and black lines represent CAT-6A cable or above.](cdf9ddce1aad69087b420b079427f1cf_img.jpg) + +Figure 4.1-2: Indoor pico cell based on Option 8 (O-RU utilizing CAT-6A cable). The diagram shows an O-CU/O-DU connected via fiber to two FHGWs. One FHGW is connected to three O-RUs via CAT-6A cables. The other FHGW is connected to one O-RU via CAT-6A cables. A legend indicates that red lines with dots represent Fiber and black lines represent CAT-6A cable or above. + +**Figure 4.1-2: Indoor pico cell based on Option 8 (O-RU utilizing CAT-6A cable)** + +## 4.2 Test equipment and tools + +Table 4.2-1 listed the main test tools. + +**Table 4.2-1: Test Tools** + +| Item | Functions | Basic configurations | +|----------------------------------|---------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------| +| Oscilloscope | Measure clock synchronization accuracy | Bandwidth: $\geq 300\text{MHz}$<br>Sampling rate: $\geq 2.5\text{GS/s}$ | +| Vector signal generator | Test GNSS automatic switching, RF performance and calibration | NR signals can be configured according to RF test requirements, and white noise signals can be emitted | +| Spectrum analyzer | Test clock synchronization accuracy, RF performance and calibration | NR signals can be demodulated according to RF test requirements | +| Power supply | Power the device under test | | +| Test UE | NR traffic test | Antenna configuration: Supports downlink MIMO<br>NR carrier frequency: Supports the test configuration | +| Oscilloscopes and current probes | Power consumption and power supply mode test | Current accuracy: within $\pm 2\%$ . | +| Voltmeter | Power consumption and power supply mode test | Voltage test accuracy: within $\pm 3\%$ .<br>DC voltage range: 100V<br>AC voltage range: 500V | + +## 4.3 Test configuration + +Configure A: Band n41 + +NR signal: channel bandwidth 100MHz, subcarrier spacing 30kHz, total RB 273 + +The NR uses a 5ms frame structure (DDDDDDDSUU) with a special sub-frame ratio of 6:4:4 + +Configure B: Band n78 + +NR signal: channel bandwidth 100MHz, subcarrier spacing 30kHz, total RB 273 + +The NR uses a 5ms frame structure (DDDSUDDSUU) with a special sub-frame ratio of 10:2:2 + +# 5 O-CU and O-DU Tests + +## 5.1 GNSS synchronization accuracy + +| | | +|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Diagram of the test setup for GNSS synchronization accuracy. A Signal source is connected to a Combiner. The Combiner is connected to the O-DU. The O-DU outputs a 1PPS(10MHz) signal to an Oscilloscope. The Oscilloscope also receives a 1PPS(10MHz) signal from an Atomic clock. The Atomic clock is also connected to a second antenna." data-bbox="598 801 1353 1339" src="0cd924708b2ae29bc0557ff6e593fd1a_img.jpg"/> | +| Purpose of the test | Verify that the O-DU supports GPS/Beidou dual-mode synchronization, and has an automatic switching function. | +| Test conditions | <ol style="list-style-type: none"> <li>1. The GPS/Beidou dual-mode antenna is connected to the O-DU;</li> <li>2. The GPS/Beidou dual-mode antenna is connected to the atomic clock;</li> <li>3. Both the O-DU and GPS/Beidou receivers work normally after powering on.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>1. The GPS/Beidou receiver is set as the clock source of the O-DU through the operation and maintenance station;</li> <li>2. Power on the O-DU, and keep all devices powered on for 60 minutes;</li> <li>3. The 1PPS signal output by the atomic clock (which can be replaced by another O-DU) and the 1PPS output by the O-DU are introduced into the oscilloscope, the 1PPS signal channel of the atomic clock is set as the trigger channel. Observe the phase error between the 1PPS output by the O-DU and the 1PPS signal output by the atomic clock.</li> <li>4. The 10MHz clock output by the atomic clock and the 10MHz clock output by the O-DU were introduced into the frequency meter, and the 10MHz clock output by the atomic clock was used as the standard frequency to observe the frequency error between the 10MHz clock output by the O-DU and the 10MHz clock output by the atomic clock.</li> </ol> | + +| | | +|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>Set the interference source to the same frequency point signal as the GPS, drown the GPS signal by adding noise, and repeat steps 3 and 4.</li> <li>Set the interference source to the same frequency signal as the Beidou, drown the Beidou signal by adding noise, and repeat steps 3 and 4.</li> </ol> | +| Expected results | When GPS/Beidou dual-mode are working at the same time, and when either synchronization source disappears, the synchronization accuracy is compliant to O-RAN.WG7.IPC-HAR.0-v03.00. | + +## 5.2 IEEE 1588v2 synchronization accuracy + +| | | +|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram showing the setup for IEEE 1588v2 synchronization accuracy testing. A 1588 Server and an Atomic clock are connected to a Transport Network (dashed box). The Transport Network is connected to an O-DU via a GE interface. The O-DU outputs a 1PPS(10MHz) signal to an Oscilloscope. The Atomic clock also outputs a 1PPS(10MHz) signal to the Oscilloscope." data-bbox="539 712 1375 1258" src="1b77b866292c29500aa70de068e2564c_img.jpg"/> | +| Purpose of the test | Verify that the O-DU supports IEEE 1588v2 in-band synchronization. | +| Test conditions | <ol style="list-style-type: none"> <li>Build a transport network;</li> <li>Connect the O-DU to the transport network via Ethernet;</li> <li>The O-DU works normally after powering on.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>The 1588 clock is set as the clock source of the O-DU through the operation and maintenance station, and the in-band mode (synchronous signal is transmitted through the GE transmission interface) is used to build the test environment according to the in-band test block diagram;</li> <li>Power on the O-DU, and keep all devices powered on for 60 minutes;</li> <li>Introduce the 1PPS signal output by the atomic clock (which can be replaced by another O-DU) and the 1PPS output by the O-DU into the oscilloscope, set the 1PPS signal channel output by the atomic clock as the trigger channel, and observe the phase error between the 1PPS output by the O-DU and the 1PPS signal output by the atomic clock.</li> <li>The 10MHz clock output of the atomic clock and the 10MHz clock output of the O-DU were introduced into the frequency meter, and the frequency error between the 10MHz clock output of the O-DU and the 10MHz clock output by the atomic clock was observed by using the 10MHz clock output of the atomic clock as the standard frequency.</li> </ol> | + +| | | +|------------------|--------------------------------------------------------------------------| +| Expected results | The synchronization accuracy is compliant to O-RAN.WG7.IPC-HAR.0-v03.00. | +|------------------|--------------------------------------------------------------------------| + +## 5.3 Clock hold-over ability + +| | | +|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Network diagram for Clock hold-over ability test. A 'Test O-DU (Holdover)' block sends a 'Frame sync signal' to an 'Oscilloscope' block. A 'Reference O-DU (GNSS locked)' block also sends a 'Frame sync signal' to the 'Oscilloscope' block. A curved arrow points from the 'Reference O-DU (GNSS locked)' block back to the 'Test O-DU (Holdover)' block, indicating a feedback loop." data-bbox="555 459 1391 795" src="e0d5229175015257d7246b59516002eb_img.jpg"/> | +| Purpose of the test | Verify whether the O-DU master clock can meet the requirement that the synchronization retention time is not less than 24 hours after the synchronization source is lost. | +| Test conditions | <ol style="list-style-type: none"> <li>Build a test environment according to the network diagram;</li> <li>The O-DU under test is powered on and enters the GPS synchronization state for more than 4 hours.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>The frame synchronization output of the reference O-DU (which needs to ensure that the reference O-DU remains GPS locked during the test) is used as the reference signal, and the frame synchronization signal (1PPS or 10ms) output by the O-DU under test is observed with an oscilloscope;</li> <li>Unplug the input of the synchronization source (including GPS and IEEE 1588v2) of the O-DU under test and enter the master clock hold mode of the base station. Observe and record the time deviation between the synchronization signals of the two frames of the observation at this moment;</li> <li>The O-DU under test operates for 24 hours in master clock hold mode, and the time deviation between the two frame synchronization signals is observed and recorded.</li> </ol> | +| Expected results | After the synchronization source of the base station is lost, within 24 hours of the self-timing of the master clock, the temperature drift of the frame synchronization signal of the O-DU under test is less than 3μs. | + +## 5.4 Power supply method + +| | | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Network diagram for Power supply method test. A sequence of blocks: 5GC connected to O-CU/O-DU, which is connected to FHGW, which is connected to O-RU, which is connected to 5G UE. An NMS block is connected to the O-CU/O-DU block." data-bbox="475 1720 1423 1863" src="263a6ff571b360563a8e9c3b7a7a2408_img.jpg"/> | +| Purpose of the test | <ol style="list-style-type: none"> <li>Verify that the O-DU supports DC -48 VDC (-40V~-57V) power supply;</li> <li>Verify that the O-DU supports AC 220 VAC (140V~300V) and 50Hz (45Hz~65Hz) power supply modes.</li> </ol> | + +| | | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Test conditions | <ol style="list-style-type: none"> <li>1. The NR channel bandwidth is set to 100 MHz.</li> <li>2. The uplink and downlink services are UDP full buffer services.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>1. The O-DU, FHGW, and O-RU all work normally after powering on.</li> <li>2. For single-mode O-DUs, establish 1 NR 100MHz cell;</li> <li>3. The O-RU is connected to a 5G test UE to confirm that the uplink and downlink rates of a single user can reach 90% of the peak rate of both uplink 2 streams and downlink 2 streams at the same time.</li> <li>4. The power supply voltage is pulled down to the minimum working voltage specified in the technical requirements, and the operation of the O-DU is observed through the test terminal, and the uplink and downlink rates of a single user can reach 90% of the peak rate of the uplink 2 streams and the downlink 2 streams required by the technical requirements at the same time.</li> <li>5. Pull the power supply voltage up to the highest working voltage specified in the technical requirements, observe the operation of the O-DU through the test UE, and confirm that the uplink and downlink rate of a single user can reach 90% of the peak rate of the uplink 2 streams and the downlink 2 streams required by the technical requirements.</li> </ol> | +| Expected results | <ol style="list-style-type: none"> <li>1. O-DU supports DC -48 VDC (-40v ~ -57v) or AC 220V power supply, voltage range of 140V~ 300v, frequency range of 45Hz ~ 65Hz.</li> <li>2. The uplink and downlink rate of a single user can reach 90% of the peak rate.</li> </ol> | + +## 5.5 Dimension and volume + +| | | +|----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Diagram of an O-DU unit showing its dimensions: Depth (including connectors), Width, and Height." data-bbox="644 1218 1267 1496" src="25614ad1c396d94e47a6d30b1e8d647c_img.jpg"/> <p>The diagram shows a 3D perspective view of a rectangular O-DU unit. Three dimensions are labeled with double-headed arrows: 'Depth (including connectors)' for the front-to-back dimension, 'Width' for the side-to-side dimension, and 'Height' for the top-to-bottom dimension. The unit is labeled 'O-DU' on its front face.</p> | +| Purpose of the test | Confirm the dimension and the volume of the O-DU. | +| Test conditions | Confirm that the board configuration of the O-DU is the same as that of the O-DU during the capacity test. | +| Test steps | <ol style="list-style-type: none"> <li>1. Use a tape measure or vernier caliper to measure the length, width and height of the O-DU and record them.</li> <li>2. Calculate the O-DU volume.</li> </ol> | +| Expected results | O-DU has a standard 19" rack and can be built into any standard rack or placed independently. The height does not exceed 2U, the depth (including the connector) must be less than 450mm. | + +## 5.6 Cell capacity + +| | | +|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram: A 5GC block connects to an O-CU/O-DU block. The O-CU/O-DU block is connected to an NMS block. The O-CU/O-DU block also connects to four parallel paths, each consisting of an FHGW block, an O-RU block, and a 5G UE block. Vertical ellipses indicate multiple such paths." data-bbox="507 324 1396 694" src="44edac048e8bb02e806143a680b0cf5f_img.jpg"/> | +| Purpose of the test | Verify the maximum capability of the 100MHz NR cell that the O-DU is capable of supporting. | +| Test conditions | <ol style="list-style-type: none"> <li>Referring to the network block diagram, the O-DU is tested according to the maximum capacity;</li> <li>The NR channel bandwidth is set to 100MHz.</li> <li>Working mode 1: UDP full buffer service is used for uplink and downlink.</li> <li>Working mode 2: Upstream FTP service test (file provided by tester).</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>The device is powered on and works normally, and the O-DU antenna mode is configured as 2 antennas.</li> <li>In the working mode 1, check the uplink and downlink rate of the cell (the UE side and the server side are monitored separately for the peak rate), when the uplink and downlink peak rate of the cell reaches 90% of the technical requirements at the same time and is stable for 10 seconds, the rate is considered valid, the number of NR cells supported by the O-DU is recorded, and the uplink and downlink rate of each UE is recorded. And use the digital display power supply to record the voltage and current of the O-DU;</li> <li>In the working mode 2: On the basis of working mode 1, the tester randomly designates an NR cell to perform an uplink FTP test, checks whether the uplink rate of the cell (the UE side and the server side are monitored for the peak rate) is the same as the uplink rate in step 2, and checks the uploaded file and voltage and current on the server side.</li> </ol> | +| Expected results | The cell capacity is compliant to O-RAN.WG7.IPC-HAR.0-v03.00. | + +## 5.7 Power consumption + +| | | +|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram for power consumption test. A 5GC block is connected to an O-CU/O-DU block. The O-CU/O-DU block is connected to an NMS block. The O-CU/O-DU block is also connected to four parallel paths, each consisting of an FHGW block, an O-RU block, and a 5G UE block. Vertical ellipses indicate multiple such paths." data-bbox="512 320 1385 696" src="0be0fe33eaa74ee33aeaf5f166c4c7be_img.jpg"/> | +| Purpose of the test | Verify the power consumption capability of the O-DU. | +| Test conditions | <ol style="list-style-type: none"> <li>1. The O-DU is tested according to 4 100MHz NR cells; The NR channel bandwidth is set to 100MHz.</li> <li>2. The uplink and downlink use UDP full buffer service.</li> <li>3. The O-DU is powered by a program-controlled power supply.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>1. The device is powered on and works normally, and the O-DU antenna mode is configured as 2 antennas.</li> <li>2. When the uplink and downlink peak rate of the cell reaches 90% of the technical requirements and is stably maintained for 10 seconds, the rate is considered valid, the number of NR cells supported by the O-DU is recorded, and the uplink and downlink rate of each UE is recorded.</li> <li>3. Record the voltage and current of the O-DU monitored by the program-controlled power supply.</li> </ol> | +| Expected results | The power consumption and the peak rate meets the requirements in O-RAN.WG7.IPC-HAR.0-v03.00. | + +# 6 O-RU Hardware Tests + +## 6.1 Operating frequency band, bandwidth and carrier configuration + +| | | +|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram for O-RU hardware tests. A 5GC block is connected to an O-CU/O-DU block. The O-CU/O-DU block is connected to an NMS block. The O-CU/O-DU block is also connected to an FHGW block, which is connected to an O-RU block, which is finally connected to a 5G UE block." data-bbox="512 1704 1385 1951" src="eb2185736d9e63adbfb0b2dcba475adf_img.jpg"/> | +| Purpose of the test | Confirm the O-RU's ability to support the requirements of the frequency band, bandwidth and carrier configuration. | + +| | | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Test conditions | <p>There are 1 types of carrier configuration schemes for RF units with 100M NR bandwidth:</p> <p>Carrier configuration 1: 100M NR;</p> <ol style="list-style-type: none"> <li>1. The uplink and downlink use UDP full buffer services;</li> <li>2. O-RU full power transmission;</li> <li>3. The O-DU is powered by a program-controlled power supply.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>1. Refer to the network diagram to build the test environment;</li> <li>2. The O-DU is connected to no less than 1 O-RU, and both the O-DU and the O-RU work normally after powering on;</li> <li>3. Each cell is tested for the uplink and downlink peak rate;</li> <li>4. Observe the number of carriers and the bandwidth of each carrier, observe the uplink and downlink rate of each carrier (UE side), record the number of carriers supported by the radio unit, the cell frequency and bandwidth, and the uplink and downlink rate of each carrier;</li> <li>5. During the above test, the voltage and current of the program-controlled power supply are recorded;</li> <li>6. Record the number and rate of optical modules.</li> </ol> | +| Expected results | <p>For 100M devices, it can support carrier configuration 1 and the frequency point is correct.</p> <p>If carrier configuration 1 can be established, and the uplink and downlink peak rates of the NR cell are not less than 90% of the technical requirements, the device supports this carrier configuration.</p> | + +## 6.2 TX power and RF power configuration + +| | | +|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram: O-CU/O-DU connected to FHGW, which is connected to O-RU. O-RU has Port 1 and Port 2." data-bbox="612 1335 1302 1424" src="b0144970146df9869f71fe11fe78802c_img.jpg"/> <pre> graph LR OCUO["O-CU/O-DU"] --- FHGW["FHGW"] FHGW --- ORU["O-RU"] ORU --- P1["Port 1"] ORU --- P2["Port 2"] </pre> | +| Purpose of the test | <ol style="list-style-type: none"> <li>1. Confirm that the O-RU supports RF power configuration;</li> <li>2. Confirm the transmit power of the O-RU.</li> </ol> | +| Test conditions | <ol style="list-style-type: none"> <li>1. 1 O-DU cascade 1 FHGW, 1 FHGW cascade 1 O-RU;</li> <li>2. The NR standard configured as 100MHz signal bandwidth.</li> </ol> | +| Test steps | <p>Transmit power:</p> <ol style="list-style-type: none"> <li>1. Start the transmitter, the NR working mode is NR-FR1-TM3.1a, and the power of each carrier is distributed according to the principle of maximum power and equal power spectral density.</li> <li>2. For each carrier, the integrated power of all downlink subframes in the channel bandwidth for 20ms is measured and recorded;</li> <li>3. Traverse all RF channels and repeat steps 1~2 to record separately.</li> </ol> <p>Channel power independent configuration:</p> | + +| | | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>1. Start the transmitter, the NR working mode is NR-FR1-TM3.1a, and the power of each carrier is distributed according to the principle of maximum power and equal power spectral density.</li> <li>2. Adjusted the power of each channel separately, and the integrated power of all downlink subframes in the channel bandwidth for 20ms is measured and recorded.</li> </ol> | +| Expected results | <p>Principle of Transmitting Power Judgment:</p> <p>The total transmit power meets the requirements in O-RAN.WG7.IPC-HAR.0-v03.00;</p> <p>Principle of channel power configuration:</p> <p>Support channel independent power adjustment (error does not exceed <math>\pm 1</math>dB).</p> | + +## 6.3 Number of RF channels + +| | | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Purpose of the test | Confirm the number of RF channels supported by the O-RU; | +| Test conditions | Preparation of O-RU. | +| Test steps | <ol style="list-style-type: none"> <li>1. For the built-in antenna version, the number of RF channels of 5G NR is counted after the antenna oscillator is removed;</li> <li>2. For the external antenna version, count the number of output RF ports;</li> </ol> | +| Expected results | <p>RF channel determination principle for 2-channel equipment:</p> <ol style="list-style-type: none"> <li>1. For the built-in antenna version, the number of 5G NR RF channels should be two;</li> <li>2. For the external antenna version, the number of output RF ports should be two.</li> </ol> <p>RF channel determination principle for 4-channel equipment:</p> <ol style="list-style-type: none"> <li>3. For the built-in antenna version, the number of 5G NR RF channels should be four;</li> <li>4. For the external antenna version, the number of output RF ports should be four.</li> </ol> | + +## 6.4 Weight, dimensions, and volume + +| | | +|---------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Purpose of the test | Confirm the weight and dimensions of the O-RU; | +| Test conditions | Open the O-RU chassis and confirm that the internal hardware modules are complete. | +| Test steps | <ol style="list-style-type: none"> <li>1. Place the O-RU on the scale and read out the weight of the O-RU;</li> <li>2. The maximum length, width and height of the main structure of the O-RU are directly measured with a tape measure (excluding the size of the O-RU joints and handles) to calculate the volume of the O-RU;</li> </ol> | +| Expected results | The weight, dimension and volume of the O-RU meet the requirements in O-RAN.WG7.IPC-HAR.0-v03.00. | + +## 6.5 Power supply capability + +| | | +|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | | +| Purpose of the test | Confirm the power supply requirements and transmission distance of the O-RU. | +| Test conditions | <ol style="list-style-type: none"> <li>When the O-RU uses PoE power supply mode, the distance should not be less than 100m (the network cable must have a clear length indication);</li> <li>When the O-RU uses the power supply mode of the optical fiber with integrated power cable, the distance shall not be less than 200m (the optical fiber with integrated power cable must have a clear length indication);</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>According to the requirements of the test conditions, the test system is built, 1 O-DU is cascaded with 1 FHGW, 1 FHGW is cascaded with 1 O-RU;</li> <li>For devices with a 100 MHz signal bandwidth, two 5G NR UEs are connected to the O-RU;</li> <li>Through the spectrum analyzer, each carrier is observed to be established normally, and each carrier is tested according to the maximum power transmission, and the uplink and downlink peak rate are tested.</li> <li>During the test, the distance between the O-RU and the FHGW is recorded;</li> <li>During the test, observe whether the O-RU can be powered by PoE or optical fiber with integrated power cable.</li> </ol> | +| Expected results | <ol style="list-style-type: none"> <li>FHGW has the ability to provide PoE or optical fiber with integrated power cable power supply to O-RU equipment;</li> <li>If the O-RU uses PoE power supply mode, the distance from FHGW to O-RU is not less than 100m;</li> <li>If the O-RU uses the power supply mode of optical fiber with integrated power cable, the distance from FHGW to O-RU is not less than 200m.</li> </ol> | + +## 6.6 Power consumption + +The O-RU power consumption test is completed using the RF test environment. + +For the O-RU device under test that is powered by PoE or optical fiber with integrated power cable, the network cable or composite cable with the power supply lead stripped out should be prepared in advance, and the actual supply voltage should be read through the voltmeter at the power supply socket of the O-RU, and the actual supply current should be read through the oscilloscope current probe. The accuracy of voltmeters and current probes needs to be verified by a tester. + +Full load power consumption test method: During the test process of each RF performance case, the supply voltage and current of the O-RU are recorded, and the average power consumption of each test case is regarded as the full load power consumption. For multi-band devices, all bands must transmit at rated power. + +# 7 O-RU RF Tests + +## 7.1 Tx Power accuracy + +| | | +|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Block diagram showing the test setup: O-RU connected to an optional Attenuator, then an optional Filter, and finally a Spectrum Analyzer." data-bbox="564 436 1353 528" src="0861f4d49a1a30627755a25e617fb965_img.jpg"/> <pre> graph LR O-RU --> Attenuator[Attenuator (Optional)] Attenuator --> Filter[Filter (Optional)] Filter --> SpectrumAnalyzer[Spectrum Analyzer] </pre> | +| Purpose of the test | Verify that the rated transmit power and stability of the device under test meet the requirements. | +| Test conditions | <ol style="list-style-type: none"> <li>Set up the test environment according to the reference network and calibrate the path loss, which must be added to the measuring equipment;</li> <li>The measuring equipment is set to be synchronized and frame-triggered by an external reference signal, and data acquisition is performed only in the downstream time slot.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>The configuration is completed according to the frequency band and the number of carriers supported by the device;</li> <li>Start the transmitter, the NR working mode is NR-FR1-TM3.1a, and transmit at rated power;</li> <li>Using a spectrum analyzer, the integrated power of all downlink subframes in the channel bandwidth for 20ms is measured separately for each carrier;</li> <li>Traverse all low and high frequencies of all RF channels and record them separately.</li> </ol> | +| Expected results | The maximum transmit power per carrier per channel is within $\pm 2$ dB of its rated power. | + +## 7.2 EVM + +| | | +|----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Block diagram showing the test setup: O-RU connected to an optional Attenuator, then an optional Filter, and finally a Spectrum Analyzer." data-bbox="564 1305 1353 1397" src="c3931b4d9cf8eafccf7fc72885ab4ce3_img.jpg"/> <pre> graph LR O-RU --> Attenuator[Attenuator (Optional)] Attenuator --> Filter[Filter (Optional)] Filter --> SpectrumAnalyzer[Spectrum Analyzer] </pre> | +| Purpose of the test | Verify that the EVM of the device under test meets the requirements. | +| Test conditions | <ol style="list-style-type: none"> <li>Set up the test environment according to the reference network and calibrate the path loss, which must be added to the measuring equipment;</li> <li>The measuring equipment is set to be synchronized and frame-triggered by an external reference signal, and data acquisition is performed only in the downstream time slot.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>The configuration is completed according to the frequency band and the number of carriers supported by the device;</li> <li>Start the transmitter, the NR working mode is NR-FR1-TM3.1a, transmit at rated power, and measure the EVM of the PDSCH channel of each NR carrier under 256QAM modulation;</li> <li>Traverse all low and high frequencies of all RF channels and record them separately.</li> </ol> | +| Expected results | <p>All test results meet the following technical requirements:</p> <ol style="list-style-type: none"> <li>The EVM under 64QAM modulation is not higher than 5%;</li> </ol> | + +| | | +|--|------------------------------------------------------------| +| | 2. The EVM under 256QAM modulation is no higher than 3.5%. | +|--|------------------------------------------------------------| + +## 7.3 ACLR + +| | | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram for ACLR: O-RU -> Attenuator (Optional) -> Filter (Optional) -> Spectrum Analyzer" data-bbox="564 454 1353 548" src="1fe153834fb99e2540143383446ba2b2_img.jpg"/> | +| Purpose of the test | Verify that the ACLR of the device under test meets the requirements. | +| Test conditions | <ol style="list-style-type: none"> <li>1. Set up the test environment according to the reference network and calibrate the path loss, which must be added to the measuring equipment;</li> <li>2. The measuring equipment is set to be synchronized and frame-triggered by an external reference signal, and data acquisition is performed only in the downstream time slot.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>1. The configuration is completed according to the frequency band and the number of carriers supported by the device;</li> <li>2. Start the transmitter, the NR working mode is NR-FR1-TM3.1a, and transmit at rated power;</li> <li>3. Using a spectrum analyzer, for each carrier, the ACLR of the two-sided adjacent channel is measured separately (in the case of dual carriers, only the single-sided adjacent channel is measured), and the detection mode is true RMS voltage or true average power;</li> <li>4. Traverse all low and high frequencies of all RF channels and record them separately.</li> </ol> | +| Expected results | The ACLR of the NR signal is no higher than -45dBc on each channel. | + +## 7.4 Spurious emission + +| | | +|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram for Spurious emission: O-RU -> Attenuator (Optional) -> Filter (Optional) -> Spectrum Analyzer" data-bbox="564 1357 1353 1451" src="f2bb3487433aa648cce6c444ac4cd814_img.jpg"/> | +| Purpose of the test | Verify that the spurious emissions of the device under test meet the requirements. | +| Test conditions | <ol style="list-style-type: none"> <li>1. Set up the test environment according to the reference network and calibrate the path loss, which must be added to the measuring equipment;</li> <li>2. The measuring equipment is set to be synchronized and frame-triggered by an external reference signal, and data acquisition is performed only in the downstream time slot.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>1. The configuration is completed according to the frequency band and the number of carriers supported by the device;</li> <li>2. Start the transmitter, the NR working mode is NR-FR1-TM3.1a, and transmit at rated power;</li> <li>3. According to the definition of spurious emission, the spectrum analyzer is set to RBW to 100kHz or 1MHz, Detector to RMS or Average, Trace to Max-hold, and Sweep Count to 10 times.</li> <li>4. Set the start frequency and end frequency according to the spurious frequency band, and after the Sweep Count reaches the pre-set value, find the peak value in the frequency band</li> </ol> | + +| | | +|------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>and record it as the spurious value in the frequency band, and save the instrument screenshot;</p> <p>5. Traverse all low and high frequencies of all RF channels and record them separately.</p> | +| Expected results | The spurious emission of the device is compliant to O-RAN.WG7.IPC-HAR.0-v03.00. | + +## 7.5 Reference sensitivity + +| | | +|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram: Vector Signal Generator -> Attenuator (Optional) -> O-RU -> Throughput/bit error rate Statistics Tools" data-bbox="477 595 1439 703" src="722c23607a0502ed5793300e93bf6ebc_img.jpg"/> <pre> graph LR A[Vector Signal Generator] --> B[Attenuator (Optional)] B --> C[O-RU] C --> D[Throughput/bit error rate Statistics Tools] </pre> | +| Purpose of the test | Verify that the reference sensitivity of the device under test meets the requirements. | +| Test conditions | <ol style="list-style-type: none"> <li>Set up the test environment according to the reference network and calibrate the path loss, which must be added to the measuring equipment;</li> <li>Set the measuring equipment to be synchronized and triggered by external reference signals;</li> <li>If the device supports more than one frequency band, all frequency bands must maintain the power rating for transmission.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>The configuration is completed according to the frequency band and the number of carriers supported by the equipment, and all cells are established, and all supported frequency bands transmit downlink signals at rated power;</li> <li>Set up a vector signal generator and output an uplink reference measurement signal as required;</li> <li>For each carrier, at least 10,000 subframes of data are received to calculate throughput using the throughput statistics or bit error rate statistics tools of the base station maintenance station.</li> <li>Adjust the output power value of the vector signal generator so that the throughput statistical value is slightly greater than 95%, and the power value is recorded as the reference sensitivity;</li> <li>Traversal test of carriers of all NR formats;</li> <li>Traverse all low and high frequencies of all RF channels and record them separately.</li> </ol> | +| Expected results | NR reference sensitivity is not higher than -94dBm. | + +## 7.6 ACS + +| | | +|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram showing two signal paths. The top path consists of a Vector Signal Generator connected to an optional Attenuator. The bottom path consists of a Vector Signal Generator (Interference Signal) connected to an optional Attenuator/Amplifier, which is then connected to an optional Filter. The outputs of both paths are combined at a Combiner, followed by an O-RU, and finally Throughput/bit error rate Statistics Tools." data-bbox="475 324 1441 584" src="a1ab6125810fa3c4ab752737a4106f2b_img.jpg"/> <pre> graph LR VSG1[Vector Signal Generator] --> A1[Attenuator (Optional)] VSG2[Vector Signal Generator (Interference Signal)] --> AA[Attenuator/Amplifier (Optional)] AA --> F[Filter (Optional)] A1 --> C[Combiner] F --> C C --> ORU[O-RU] ORU --> T[Throughput/bit error rate Statistics Tools] </pre> | +| Purpose of the test | Verify that the ACS of the device under test meets the requirements. | +| Test conditions | <ol style="list-style-type: none"> <li>1. Set up the test environment according to the reference network and calibrate the path loss, which must be added to the measuring equipment;</li> <li>2. Set the measuring equipment to be synchronized and triggered by external reference signals;</li> <li>3. If the device supports more than one frequency band, all frequency bands must maintain the power rating for transmission.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>1. The configuration is completed according to the frequency band and the number of carriers supported by the equipment, and all cells are established, and all supported frequency bands transmit downlink signals at rated power;</li> <li>2. Set the vector signal generator, output the upstream reference measurement signal and the ACS interference signal as required, and note that the interference signal should have an ACLR of at least -49dBc to exclude the influence of the adjacent channel leakage of the interference signal on this test case;</li> <li>3. For each carrier, at least 10,000 subframes of data are received to calculate throughput using the throughput statistics or bit error rate statistics tools of the base station maintenance station.</li> <li>4. According to the power requirements, fix the useful signal, adjust the interference signal, make the throughput statistical value slightly greater than 95%, and record the interference signal power value;</li> <li>5. According to the power requirements, fix the interference signal, adjust the useful signal, make the throughput statistical value slightly greater than 95%, and record the useful signal power value;</li> <li>6. Traversal test of carriers of all NR formats;</li> <li>7. Traverse all low and high frequencies of all RF channels and record them separately.</li> </ol> | +| Expected results | NR system, the useful signal is not higher than -88dBm, and the interference signal is not less than -44dBm. | + +## 7.7 ICS + +| | | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram showing two parallel paths. The top path consists of a Vector Signal Generator connected to an optional Attenuator. The bottom path consists of a Vector Signal Generator (Interference Signal) connected to an optional Attenuator/Amplifier, which is then connected to an optional Filter. The outputs of both paths are combined at a Combiner, followed by an O-RU, and finally Throughput/bit error rate Statistics Tools." data-bbox="475 324 1441 584" src="a1ab6125810fa3c4ab752737a4106f2b_img.jpg"/> <pre> graph LR VSG1[Vector Signal Generator] --> A1[Attenuator (Optional)] VSG2[Vector Signal Generator (Interference Signal)] --> AA[Attenuator/Amplifier (Optional)] AA --> F[Filter (Optional)] A1 --> C[Combiner] F --> C C --> ORU[O-RU] ORU --> T[Throughput/bit error rate Statistics Tools] </pre> | +| Purpose of the test | Verify that the ICS of the device under test meets the requirements. | +| Test conditions | <ol style="list-style-type: none"> <li>1. Set up the test environment according to the reference network and calibrate the path loss, which must be added to the measuring equipment;</li> <li>2. Set the measuring equipment to be synchronized and triggered by external reference signals;</li> <li>3. If the device supports more than one frequency band, all frequency bands must maintain the power rating for transmission.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>1. The configuration is completed according to the frequency band and the number of carriers supported by the equipment, and all cells are established, and all supported frequency bands transmit downlink signals at rated power;</li> <li>2. Set up a vector signal generator, output the upstream reference measurement signal and ICS interference signal as required, and note that the interference signal should have an ACLR of at least -49dBc to eliminate the influence of adjacent channel leakage of the interference signal on this test case;</li> <li>3. For each carrier, at least 10,000 subframes of data are received to calculate throughput using the throughput statistics or bit error rate statistics tools of the base station maintenance station.</li> <li>4. According to the power requirements, fix the useful signal, adjust the interference signal, make the throughput statistical value slightly greater than 95%, and record the interference signal power value;</li> <li>5. According to the power requirements, fix the interference signal, adjust the useful signal, make the throughput statistical value slightly greater than 95%, and record the useful signal power value;</li> <li>6. Traversal test of carriers of all NR formats;</li> <li>7. Traverse all low and high frequencies of all RF channels and record them separately.</li> </ol> | +| Expected results | NR system, the useful signal is not higher than -91dBm, and the interference signal is not less than -63.4dBm. | + +## 7.8 Anti-blocking + +| | | +|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference networking | <img alt="Reference networking diagram showing two parallel paths. The top path consists of a Vector Signal Generator connected to an optional Attenuator. The bottom path consists of a Vector Signal Generator (Interference Signal) connected to an optional Attenuator/Amplifier, which is then connected to an optional Filter. The outputs of both paths are combined at a Combiner, followed by an O-RU, and finally Throughput/bit error rate Statistics Tools." data-bbox="475 324 1439 586" src="199faf8ef34333df14621bc64dffcf2f_img.jpg"/> <pre> graph LR VSG1[Vector Signal Generator] --> ATT1[Attenuator (Optional)] VSG2[Vector Signal Generator (Interference Signal)] --> ATT2[Attenuator/Amplifier (Optional)] ATT2 --> FIL[Filter (Optional)] ATT1 --> COM[Combiner] FIL --> COM COM --> ORU[O-RU] ORU --> TBS[Throughput/bit error rate Statistics Tools] </pre> | +| Purpose of the test | Verify that the anti-blocking performance of the device under test meets the requirements. | +| Test conditions | <ol style="list-style-type: none"> <li>Set up the test environment according to the reference network and calibrate the path loss, which must be added to the measuring equipment;</li> <li>Set the measuring equipment to be synchronized and triggered by external reference signals;</li> <li>If the device supports more than one frequency band, all frequency bands must maintain the power rating for transmission.</li> </ol> | +| Test steps | <ol style="list-style-type: none"> <li>The configuration is completed according to the frequency band and the number of carriers supported by the equipment, and all cells are established, and all supported frequency bands transmit downlink signals at rated power;</li> <li>Set up a vector signal generator, and output the uplink reference measurement signal and the blocking interference signal as required;</li> <li>For each carrier, at least 10,000 subframes of data are received to calculate throughput using the throughput statistics or bit error rate statistics tools of the base station maintenance station.</li> <li>According to the power requirements, fix the useful signal, adjust the interference signal, make the throughput statistical value slightly greater than 95%, and record the interference signal power value;</li> <li>According to the power requirements, fix the interference signal, adjust the useful signal, make the throughput statistical value slightly greater than 95%, and record the useful signal power value;</li> <li>Traversal test of carriers of all NR formats;</li> <li>Traverse all low and high frequencies of all RF channels and record them separately.</li> </ol> | +| Expected results | The anti-blocking performance of the device is compliant to O-RAN.WG7.IPC-HAR.0-v03.00. | + +# --- Annex (informative): Change history + +| Date | Revision | Description | +|------|----------|-------------| +| | | | +| | | | +| | | | +| | | | \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/09bbf29437733f966ca999242382a8fe_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/09bbf29437733f966ca999242382a8fe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..57847885ac185301fbe33ede423234f8cf8231a0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/09bbf29437733f966ca999242382a8fe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32d3dd09c21bc452834492f9ee25ac1c487f497a3f5cf7947aee8b3d673257a1 +size 65716 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..19f401a5cfbf08aa0ec7781203e69177a2b7e39d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5836b6268e1b6d229168b5e47faaaafd32832660ba85975f8ee7a6e10fc63fff +size 4560 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/1017e1097a396edb76c81b5143824bca_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/1017e1097a396edb76c81b5143824bca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e8b97a49b09c8591d781f017698bb43d5e87b4c4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/1017e1097a396edb76c81b5143824bca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b2780d5170238a4b9d4118843be5a3e5888e315ada470592210683b7ad26f824 +size 70029 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/23ff155324963d340583876f13f6f472_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/23ff155324963d340583876f13f6f472_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cfddb4992b646d41e44bf73d3f3886c0df6f2f70 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/23ff155324963d340583876f13f6f472_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9062426926542e64a579f7c3bd71887facb81ddc3221f5b862d4b764423615a +size 84792 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/544fbd27f4f51eeaf9c37e0da29a4851_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/544fbd27f4f51eeaf9c37e0da29a4851_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..356ea5ff5d05ed4c5f5bb916d5bfe887f0c732ea --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/544fbd27f4f51eeaf9c37e0da29a4851_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d6a35c0fbae2b41724e763ed04f1638ee0a9c442deb641aecff7a6e8ea6d7c46 +size 45321 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/5e264ee36b6bd6897c516fcbee35ac54_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/5e264ee36b6bd6897c516fcbee35ac54_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3efa85e507109cac953a612088e636774674697 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/5e264ee36b6bd6897c516fcbee35ac54_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0b0592d9fc0036717beadc117de5a547b5e3c76ac3ae8c547c1c26a16b7ecae7 +size 60738 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/6c32cdda348b4d6ff667eb4e37d7b143_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/6c32cdda348b4d6ff667eb4e37d7b143_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a003b2bcdabefa4806580cb8946aa7bc978baad8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/6c32cdda348b4d6ff667eb4e37d7b143_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6786334f6b2000b5d529956703d3d45966ad8cacde05d59c0321777f4c3a4dc6 +size 69172 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..27225d0aa300adaafdd4117dedc67749d0a1a206 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48cf233b970eeaabdd503be04bfc1c953c2305a08074046287524dfb5e1dcd7c +size 4522 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/8df97f43bb4b250b1d647bd375155e5a_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/8df97f43bb4b250b1d647bd375155e5a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..99d51db6a2c18dcbe6bcc1f561696a4e371a21f0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/8df97f43bb4b250b1d647bd375155e5a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ecb2d471360b4d468ad5d5c8340c5d4addd77780d4445c6363b69978de3c22e +size 4544 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/a1c2a1a8d109831cdf9592f021e6f51e_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/a1c2a1a8d109831cdf9592f021e6f51e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7d859c343a0cc920a5531ad567d8a10b14405c6c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/a1c2a1a8d109831cdf9592f021e6f51e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b25d8565108aef8ac2b6886de31956ea23ec7d802ee0c0370bd96a818ba3dfc7 +size 4531 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/b31f573cd5d4c3d66ddf01df1e8c19b1_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/b31f573cd5d4c3d66ddf01df1e8c19b1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d83121491089756a162450563af11b0b577689d8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/b31f573cd5d4c3d66ddf01df1e8c19b1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:397bf711db63aea9286f10775f429c45dc1225593de780dc6a767d9bd7e7d03d +size 39084 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/bb96090284f65d07b1b9fcd18eff51e1_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/bb96090284f65d07b1b9fcd18eff51e1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eae1b91072a8c4a88ac85bed15d1cb9155aa4435 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/bb96090284f65d07b1b9fcd18eff51e1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aff83b6a43d575ec891673915da2ee6bd03d643040e5ad728c9fde0807e2e507 +size 24619 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2b90693e69025867d0dd05d8f98d4ef9b4bf8d2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/c3c7a0d17b2aa5f331cac797d3fef9ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ed2f1f4ac06a8bc6ac44f6e3f61e762e6c8489952cf16d65bfea30fe61adb2af +size 4677 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/ca0d9a5eab1873925314e725247bd107_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/ca0d9a5eab1873925314e725247bd107_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eabc6d3403888a1a53df706955b064dae6f5b3c2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/ca0d9a5eab1873925314e725247bd107_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:29f30d90bfde69f17485a85014f8bb48cd6121d8dec93f42485056d2242c0b2b +size 59977 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/d426e979a1319bcf065ac85080280146_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/d426e979a1319bcf065ac85080280146_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0746b58f1302c523698b6c20867196296b97695d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/d426e979a1319bcf065ac85080280146_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:eb7a3b57e1d9cd649ac2baafc6734f07bbb1e712ecdd59cf698379137ec0179c +size 64262 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d73ac8b8be38faf362b1eaa59fff1f3f167364fb --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/d72b945aac5d8bdfda2b76b71be1c704_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3276e59412020445a9dbac9cf2ede064a279427afdcaa0dcf94fa0620d916726 +size 4546 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/e548714edc96b1dc582a4ba53ad220d2_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/e548714edc96b1dc582a4ba53ad220d2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f74751b0396138aa783fcf0945ea4f125b038479 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/e548714edc96b1dc582a4ba53ad220d2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9832bdd67b7e063dbc4af0e893ecb1e7905664b4165605de8e40fb87b2e867f6 +size 4528 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/e8183cd54425bfbef32e6bb21c025955_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/e8183cd54425bfbef32e6bb21c025955_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e019fb37a3d090ceb37851b9bb080e6a623d4f04 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/e8183cd54425bfbef32e6bb21c025955_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0b35e413ea8628ddd6a78fc0a1e19f86d3e2b9cfceab0544bd76abd687f69ca9 +size 44793 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/raw.md b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..6c3e766a051eea8e931c55a48789a0bfb6bfce86 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.NES.0-R003-v02.00/raw.md @@ -0,0 +1,978 @@ + + +# --- **O-RAN Work Group 7 (White-box Hardware Workgroup)****Network Energy Savings Procedures and Performance Metrics** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this report in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this report for your personal use, or copy the material of this report for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +# Contents + +| | | +|-------------------------------------------------------------------------------------------|----| +| List of figures ..... | 4 | +| List of tables ..... | 4 | +| Foreword..... | 5 | +| Modal verbs terminology ..... | 5 | +| Executive summary ..... | 5 | +| 1 Scope ..... | 6 | +| 2 References ..... | 6 | +| 2.1 Normative references ..... | 6 | +| 2.2 Informative references ..... | 7 | +| 3 Definition of terms, symbols and abbreviations..... | 7 | +| 3.1 Terms ..... | 7 | +| 3.2 Symbols ..... | 9 | +| 3.3 Abbreviations..... | 9 | +| 4 Overview of Network Energy Savings Scenarios ..... | 11 | +| 4.1 Deployment Scenarios ..... | 11 | +| 4.2 Carrier On/Off Network Energy Savings..... | 13 | +| 4.2.1 Disabling all the component carriers (CCs) and RF bands used at the O-RU site. .... | 13 | +| 4.2.2 Disabling at least one of the multiple RF bands used at the O-RU site..... | 15 | +| 4.2.3 Disabling usage of one or more CCs within a band at the O-RU site. .... | 16 | +| 4.3 RF Channel Reconfiguration Network Energy Savings ..... | 17 | +| 4.4 Active Low Power Mode ..... | 18 | +| 4.4.1 Benefit and trade-offs:..... | 20 | +| 4.5 TRX Control and Advanced Sleep modes (ASM)..... | 21 | +| 5 Network Energy Savings KPIs and Figures of Merit ..... | 23 | +| 5.1 Discussion of Energy Efficiency KPIs relevant to this NES report. .... | 23 | +| 5.2 Discussion of O-RU-specific KPIs relevant to Network energy Savings ..... | 25 | +| 5.2.1 Expected O-RU or O-RU/DU Network energy Savings Percentage..... | 25 | +| 5.2.2 Diurnal O-RU power calculator ..... | 26 | +| 5.2.3 Open-MOU Energy KPIs and requirements..... | 28 | +| 5.2.4 O-RU Power calculation tool ..... | 28 | +| 6 Mapping of low power modes to M-Plane or C-Plane commands ..... | 30 | +| 6.1 Feature to Command mapping table ..... | 30 | +| 6.2 Detailed discussion of command mapping ..... | 31 | +| 6.2.1 Disabling all RF bands ..... | 31 | +| 6.2.2 Disabling one or more bands within an O-RU ..... | 31 | +| 6.2.3 Disabling one or more CCs in a band within an O-RU ..... | 31 | +| 6.2.4 RF Channel Reconfiguration..... | 31 | +| 6.2.5 Active Low Power mode..... | 32 | +| 6.2.6 Advanced Sleep mode..... | 32 | +| 7 O-RU Hardware changes required for NES support ..... | 32 | +| 7.1 RF Processing Unit changes ..... | 32 | +| 7.2 Digital Processing Unit and Timing Unit changes..... | 32 | +| 7.3 Energy Monitoring HW and data collection ..... | 33 | +| 7.3.1 Exemplary O-RU Power Delivery Network Architecture..... | 35 | +| 8 Annex A: NES-related components for Power Monitoring ..... | 37 | +| 9 Revision history ..... | 40 | + + + +# --- List of figures + +| | | +|------------------------------------------------------------------------------------------------------------|----| +| Figure 4-1 O-DU and O-RU architecture with interfaces ..... | 12 | +| Figure 4-2: O-RU architecture..... | 12 | +| Figure 4-3: Energy Savings for O-RU Fully Disabled..... | 14 | +| Figure 4-4: Energy Savings for O-RU Band Disable ..... | 15 | +| Figure 4-5: Energy Savings for O-RU CC Disable: two CCs active (top figure), and one CC active (bottom)... | 16 | +| Figure 4-6 Active Low Power mode high level functional block diagram..... | 20 | +| Figure 5-1: O-RU diagram showing metrics for E2E latency, PRB count, and power consumption..... | 24 | +| Figure 7-1: Power monitoring timing..... | 33 | +| Figure 7-2: Exemplary O-RU Power Delivery Network support NES..... | 35 | +| Figure 7-3: Exemplary O-RU Temperature Sensor Architecture supporting NES ..... | 36 | + +# --- List of tables + +| | | +|-------------------------------------------------------------------------|----| +| Table 4-1 O-RU Deployment options to which NES applies..... | 13 | +| Table 4-2: Some of the actions of RF Channel Reconfiguration [11] ..... | 18 | +| Table 5-1 O-RU NES Mechanisms and their impact..... | 26 | +| Table 6-1 NES features and mapping to M-Plane or C-Plane commands..... | 30 | +| Table 8-1: Catalog parts for input power monitoring ..... | 38 | + +# --- Foreword + +This Technical Report (TR) has been produced by O-RAN Alliance. + +--- + +# Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules [14] (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +--- + +# Executive summary + +This technical report describes functional procedures for Network Energy Savings, with focus on the O-RU. Energy savings KPIs and estimated power reductions are also presented. The mapping of energy savings to existing M-Plane and C-Plane commands is discussed, with gaps noted (i.e., new command capabilities requiring development in O-RAN WG4.) In follow-on versions, there will be elaboration on Advanced Sleep modes, and details on O-RU hardware and firmware impact will also be covered. + +# --- 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +The present document describes Network Energy Savings methods and requirements associated mainly with the O-RU. The O-DU or CU are referenced with respect to commands from these entities, or data exchanged between O-RU and O-DU pertaining to NES. Both TDD and FDD deployments are covered as well as FR1 and FR2. + +The NES mechanisms described herein do not assume a shared O-RU architecture. Such an arrangement adds complexity to the low power control, as multiple O-DUs or O-CUs would be sharing a single O-RU. NES requirements and functionality in a shared O-RU scenario is a topic for future study. + +# --- 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +**NOTE:** While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] ORAN-WG7.DSC.0-V02.00 Technical Specification, 'Deployment Scenarios and Base Station Classes for White Box Hardware'. +- [2] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [3] 3GPP TS 38.104: "NR; Base Station (BS) radio transmission and reception". (Rel-16.3.0) +- [4] ORAN-WG4.CUS.0-v04.00 Technical Specification, 'O-RAN Fronthaul Working Group Control, User and Synchronization Plane Specification'. + +- [5] ETSI ES 202 706-1 V1.7.0 (2022-06), “Metrics and measurement method for energy efficiency of wireless access network equipment; Part 1: Power consumption - static measurement method” +- [6] O-RAN Architecture Description, O-RAN-WG1-O-RAN Architecture Description - v01.00.00 +- [7] O-RAN WG6, Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN. +- [8] ORAN-WG4.MP.0-v04.00 Technical Specification, WG4 O-RAN Management Plane Specification’. +- [9] O-RAN TIFG O-RAN End-to-End System Testing Framework v1.0. +- [10] O-RAN White Box Hardware Working Group Outdoor Macrocell Hardware Reference Design Specification +- [11] O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v01.00 +- [12] 3GPP TS 28.310 Technical Specification “Group Services and System Aspects; Management and orchestration; Energy efficiency of 5G”, V17.4.0 +- [13] ETSI ES 203 228, “Environmental Engineering (EE); Assessment of mobile network energy efficiency”, V1.3.1 +- [14] O-RAN Drafting rules: <https://oranalliance.atlassian.net/wiki/download/attachments/2203189326/O-RAN.TSC.Drafting-Rules.0-v01.00.docx?api=v2> +- [15] ETSI TS 138 141-1, 5G; NR; Base Station (BS) conformance testing Part 1: Conducted conformance testing +- [16] <https://oranalliance.atlassian.net/wiki/download/attachments/2336817208/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00.pdf?api=v2> + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [1] <https://telecominfraproject.com/wp-content/uploads/OpenRANTechnicalPriorityDocument-Rel3.xlsx>. + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: + +**Active Mode reference power consumption:** this refers to the O-RU (or O-RU/DU combo box) power consumption while user PRBs are being transmitted or received. Unless otherwise noted, for a TDD configuration we will define this to be the average O-RU power consumption for a continuous 75/25 DL/UL duty cycle, with allowance for PDCCH and PUCCH traffic as well as required symbol gaps. By default, it assumes that all available RF signal chains are enabled, for a given band, at the max bandwidth supported by the O-RU. + +**Advanced Sleep Mode reference power consumption:** this refers to the O-RU or (O-RU/DU combo box) power consumption when configured in one of the four defined sleep modes SM0-SM3. Note that a given + +O-RU may support only a subset of sleep modes SM0-SM3, or none at all. By default, the ASM reference power consumption is expressed in Watts, but a relative % reduction of power, vs the Active Mode reference power consumption above, is also acceptable. + +**Beam:** main lobe of a radiation pattern from an AAS BS + +NOTE: For certain AAS BS antenna array, there may be more than one beam. + +**Beamwidth:** In a radiation-pattern cut containing the direction of the maximum of a lobe, the angle between the two directions in which the radiation intensity is one-half the maximum value, also called as half power beamwidth. + +**Carrier aggregation:** aggregation of two or more NR or E-UTRA component carriers in order to support wider transmission bandwidths. Within a band, component carriers can be adjacent (contiguous) or non-contiguous. If multiple component carriers are sent in different bands, this corresponds to inter-band carrier aggregation. + +**Carrier Frequency:** Center frequency of the cell. + +**F1 interface:** The standard interface between an O-CU and an O-DU<sub>x</sub> specified in [8]. + +**Integrated architecture:** An architecture wherein the O-RU<sub>x</sub> and O-DU<sub>x</sub> are implemented on one platform. Each O-RU<sub>x</sub> and RF frontend are associated with one O-DU<sub>x</sub> and are connected to O-CU via F1 interface + +**Split architecture:** An architecture wherein the O-RU<sub>x</sub> and O-DU<sub>x</sub> are physically separated from one another. A switch may aggregate multiple O-RU<sub>x</sub> (s) to one O-DU<sub>x</sub>. The O-DU<sub>x</sub>, switch and O-RU<sub>x</sub> (s) are connected by the fronthaul interface as defined in [4]. + +**Transmission Reception Point (TRxP):** Antenna array with one or more antenna elements available to the network located at a specific geographical location for a specific area. + +**Occupied Bandwidth (OBW):** It refers to the bandwidth occupied by the base station when operated, defined by the sum of the active bandwidths of the band allocation(s) operated. As defined by 3GPP TS 34.121 section 5.8, occupied bandwidth is the bandwidth containing 99% of the total integrated power of the transmitted spectrum, centered on the assigned channel frequency. The bandwidth between the 0.5% power frequency points is the occupied bandwidth. + +**Instantaneous Bandwidth (IBW):** It refers to the bandwidth in which all frequency components can be simultaneously analyzed. It is defined by the frequency boundaries of the operating band(s). + +**Frequency Range:** It refers to bandwidth defined by the frequency range within which the Base Station can be operated, defined by the band-pass filter of the BS, e.g., 3.4 – 3.8 GHz (400 MHz) + +**gNB:** A RAN node providing NR user plane and control plane protocol terminations towards the UE, and connected via the NG interface to the 5GC + +**Frequency Band:** A designated frequency range for the operation of the base station and the UE radios. 5G NR frequency bands are divided into two different frequency ranges: Frequency Range 1 (FR1) that mainly includes sub-6GHz frequency bands, some of which are bands traditionally used by previous standards but has been extended to cover potential new spectrum offerings from 410MHz to 7125MHz; Frequency Range 2 (FR2) that includes the FR2-1 frequency bands from 24.25 GHz to 52.6 GHz, as well as the FR2-2 bands covering 52.6 to 71 GHz. Bands in this millimeter wave range have shorter range but higher available bandwidth than bands in the FR1. + +**Fronthaul Gateway (FHGW):** A fronthaul gateway is a physical entity that is located between a distributed unit and one or more radio units where it distributes, aggregates, and/or converts fronthaul protocols between the distributed unit and multiple radio units. + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +| | | +|----------|-------------------------------------------------------------------------------------------------| +| $N_{RB}$ | Transmission bandwidth configuration, expressed in units of resource blocks (for E-UTRA and NR) | +|----------|-------------------------------------------------------------------------------------------------| + +## 3.3 Abbreviations + +For the purposes of the present document, the [following] abbreviations [given in ... and the following] apply: + +Fronthaul interface split option as defined by O-RAN WG4, also referred to as 7-2x + +| | | +|------|------------------------------------------| +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth Generation [Mobile Communications] | +| 5GC | 5G Core | +| AAS | Active Antenna System | +| ACLR | Adjacent Channel Leakage Ratio | +| ACS | Adjacent Channel Selectivity | +| ADC | Analog to Digital Converter | +| AFE | Analog Front End | +| AFU | Antenna Filter Unit | +| ASM | Advanced Sleep Mode(s) | +| BF | Beamforming | +| BMCA | Best Master Clock Algorithm | +| BPSK | Binary Phase Shift Keying | +| BS | Base Station | +| C2C | Chip to Chip Interface | +| CA | Carrier Aggregation | +| CAL | Calibration | +| CC | Component Carrier | +| CFR | Crest Factor Reduction | +| CLK | Clock | +| CPRI | Common Public Radio Interface | +| CU | Central Unit | +| DAC | Digital to Analog Converter | +| DDC | Digital Down Conversion | +| DDR | Double Data Rate | +| DFE | Digital Front End | +| DL | Downlink | +| DPD | Digital Pre-Distortion | +| DSP | Digital Signal Processor | +| DU | Distributed Unit | +| DUC | Digital Up Conversion | + +| | | +|---------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| eCPRI | Enhanced Common Public Radio Interface | +| eNB | e-NodeB=LTE Base Station | +| gNB | g-NodeB=NR Base Station | +| EMC | ElectroMagnetic Compatibility | +| ES | Energy Savings | +| EVM | Error Vector Magnitude | +| FAPI | Functional Application Platform Interface | +| FEC | Forward Error Correction | +| FFT | Fast Fourier Transform | +| FH | Fronthaul | +| FHGW | Fronthaul Gateway | +| FHGWx→y | Fronthaul Gateway that can translate FH protocol from an O-DUx with split option x to an O-RUy with split option y, with currently available option 7-2→8. | +| FHM | Fronthaul gateway with no FH protocol translation, supporting an O-DU with split option x and an O-RU with split option x, with currently available options 6→6, 7-2→7.2, 8→8 | +| FPGA | Field Programmable Gate Array | +| GbE | Gigabit Ethernet | +| GPP | General Purpose Processor | +| IEEE | Institute of Electrical and Electronics Engineers | +| IMD | InterModulation Distortion | +| IP | Internet Protocol | +| I/O | Input/Output | +| JTAG | Joint Test Action Group | +| L1 | Layer 1, also referred to as PHY or Physical Layer | +| L2 | Layer 2, also referred to as Data Link layer in OSI model | +| L3 | Layer 3, also referred to as Network layer in OSI model | +| LLS | Lower Layer Split | +| LNA | Low Noise Amplifier | +| LTE | Long Term Evolution | +| MAC | Media Access Control | +| MIMO | Multiple Input Multiple Output | +| mMIMO | Massive Multiple Input Multiple Output | +| MCP | Multi-Chip Package | +| nFAPI | Network Functional Application Platform Interface | +| NES | Network Energy Savings | +| NC-CA | Non-contiguous Carrier Aggregation | +| NG | Next Generation | +| NR | New Radio | +| OAM | Operations, Administrations and Maintenance | +| O-CU | O-RAN Centralized Unit as defined by O-RAN | +| O-DU | O-RAN Distributed Unit as defined by O-RAN | +| O-DUx | A specific O-RAN Distributed Unit having fronthaul split option x where x may be 6, 7-2 (as defined by WG4) or 8 | +| O-RU | O-RAN Radio Unit as defined by O-RAN | +| O-RUx | A specific O-RAN Radio Unit having fronthaul split option x, where x is 6, 7-2 (as defined by WG4) or 8, and which is used in a configuration where the fronthaul interface is the same at the O-DUx | +| PA | Power Amplifier | + +| | | +|-------|-----------------------------------------| +| PCIe | Peripheral Component Interface Express | +| PDCP | Packet Data Convergence Protocol | +| PHY | Physical Layer, also referred as L1 | +| PLL | Phase Locked Loop | +| POE | Power over Ethernet | +| QAM | Quadrature Amplitude Modulation | +| QPSK | Quadrature Phase Shift Keying | +| RAN | Radio Access Network | +| RF | Radio Frequency | +| RFIC | Radio Frequency Integrated Circuit | +| RFSoc | Radio Frequency System on Chip | +| RLC | Radio Link Controller | +| RRC | Radio Resource Controller | +| RU | Radio Unit as defined by 3GPP | +| RX | Receiver | +| SDU | Service Data Unit | +| SFP | Small Form-factor Pluggable | +| SFP+ | Small Form-factor Pluggable Transceiver | +| SoC | System on Chip | +| SPI | Serial Peripheral Interface | +| SSB | Synchronization Signal Block | +| ST | Section Type | +| TR | Technical Report | +| TS | Technical Specification | +| TX | Transmitter | +| UL | Uplink | +| WG | Working Group | + +# 4 Overview of Network Energy Savings Scenarios + +The NES methods and requirements documented here can, in general, apply to all forms of O-RU deployment. Some specific Network Energy savings mechanisms may, however, not be relevant to certain O-RU architecture deployments. + +## 4.1 Deployment Scenarios + +An O-DU can interface to multiple O-RUs, as shown in the figure below. When Network Energy Savings modes are applied based on traffic reduction, as is often the case, both the O-DU and O-RU power consumption can be expected to decrease, but this document will focus on O-RU Network Energy Savings. + +![Figure 4-1: O-DU and O-RU architecture with interfaces. The diagram shows an eNB/gNB box containing an O-DU block at the top. Below the O-DU are two O-RU blocks. The O-DU is connected to each O-RU via two interfaces: LLS-C (Control Plane) and LLS-U (User Plane). Dashed lines represent the LLS-C interface, and solid lines represent the LLS-U interface. An ellipsis (...) between the two O-RU blocks indicates that there can be more than two O-RUs connected to the O-DU.](bb96090284f65d07b1b9fcd18eff51e1_img.jpg) + +Figure 4-1: O-DU and O-RU architecture with interfaces. The diagram shows an eNB/gNB box containing an O-DU block at the top. Below the O-DU are two O-RU blocks. The O-DU is connected to each O-RU via two interfaces: LLS-C (Control Plane) and LLS-U (User Plane). Dashed lines represent the LLS-C interface, and solid lines represent the LLS-U interface. An ellipsis (...) between the two O-RU blocks indicates that there can be more than two O-RUs connected to the O-DU. + +**Figure 4-1 O-DU and O-RU architecture with interfaces** + +The document ORAN-WG7.OMAC.HRD-v01.00, which provides the Hardware Reference Design spec for a Split 7-2 Outdoor Macro Cell, gives the figure below in section 2.3.1. Generally speaking, all of the sub-blocks below are subject to Network Energy Savings as a function of traffic or operational scenarios. + +![Figure 4-2: O-RU architecture. This block diagram shows the internal components of an O-RU7-2. On the left, a bidirectional arrow labeled 'O-RAN FH' connects the O-RU to 'To/From O-DU7-2'. The main processing chain consists of three blocks in series: 'eCPRI S-Plane and M-Plane Processing', 'Digital Processing Unit', and 'RF Processing Unit', connected by bidirectional arrows. A 'Timing Unit' block is positioned below the eCPRI and Digital Processing blocks, with arrows pointing up to both. A 'Power Unit' block is at the bottom, with arrows pointing up to the eCPRI, Digital Processing, and RF Processing blocks. An optional 'GNSS (optional)' block is shown on the left, receiving 'Local timing from GNSS or equivalent' (indicated by a dashed line) and providing 'Local timing from CDR' (indicated by a solid line) to the eCPRI and Timing Unit blocks.](ca0d9a5eab1873925314e725247bd107_img.jpg) + +Figure 4-2: O-RU architecture. This block diagram shows the internal components of an O-RU7-2. On the left, a bidirectional arrow labeled 'O-RAN FH' connects the O-RU to 'To/From O-DU7-2'. The main processing chain consists of three blocks in series: 'eCPRI S-Plane and M-Plane Processing', 'Digital Processing Unit', and 'RF Processing Unit', connected by bidirectional arrows. A 'Timing Unit' block is positioned below the eCPRI and Digital Processing blocks, with arrows pointing up to both. A 'Power Unit' block is at the bottom, with arrows pointing up to the eCPRI, Digital Processing, and RF Processing blocks. An optional 'GNSS (optional)' block is shown on the left, receiving 'Local timing from GNSS or equivalent' (indicated by a dashed line) and providing 'Local timing from CDR' (indicated by a solid line) to the eCPRI and Timing Unit blocks. + +**Figure 4-2: O-RU architecture** + +The NES techniques described herein can apply to FR1 and FR2 deployments. In general, the methods for energy savings can apply to both TDD and FDD. The FDD forms will be inherently different, however, and will be described in a separate section. + +| | | +|-------------------------|------------------------------------------------------------| +| Cell type | OMAC, OMC, and EMC | +| Frequency Band | Any valid FR1 or FR2 band | +| Instantaneous Bandwidth | As documented in OMC, OMAC, and EMC HRDs | +| Occupied Bandwidth | As documented in OMC, OMAC, and EMC HRDs | +| Inter site distance | As documented in OMC, OMAC, and EMC HRDs | +| Antenna Configuration | 4T4R ~ 64T64R | +| Fronthaul Type | O-RAN FH, Split Option 7.2x<br>CAT-A and CAT-B Radio Units | +| Midhaul | Split Option 2 | + +**Table 4-1 O-RU Deployment options to which NES applies** + +## 4.2 Carrier On/Off Network Energy Savings + +From WG7 point of view, carrier Off/On means disabling or enabling a tx/rx Array carrier. The feature aims at reducing O-RU power consumption by switching off/on one or more carriers of the radio access network. + +Carrier switch off/on has two modes of operation: (i) Energy savings mode in which the radio's power amplifiers remain with minimum current draw, and (ii) complete switch off (M-Plane enabled). + +In the frequency domain, there are at least three forms of carrier switch-off: + +- (a) Disabling all the component carriers (CCs) and RF bands used at the O-RU site. +- (b) Disabling at least one of the multiple RF bands used at the O-RU site +- (c) Disabling usage of one or more CCs within a band at the O-RU site. + +All of the above actions shall allow for power reductions in the O-RU, with item (a) realizing the greatest reduction. + +### 4.2.1 Disabling all the component carriers (CCs) and RF bands used at the O-RU site. + +In this scenario, the cell or cell sector is disabled for some duration, e.g., several hours, and does not transmit or receive an RF signal for any of its supported Radio Access Technologies (RATs). It is still necessary for the O-RU to keep at least some of the fiber or wired links to the O-DU active, in order to receive M-Plane messages to resume operation, or report other management parameters. + +During this O-RU\_Full\_Disable state, the actual power savings will be vendor-dependent. The figure below provides an exemplary depiction of which O-RU sub-blocks would be in the lowest power states. + +![Figure 4-3: Energy Savings for O-RU Fully Disabled. The diagram shows the internal components of an O-RU7-2 unit. At the top, three colored boxes indicate power states: 'Fully active pwr state' (pink), 'Lowest pwr state' (green), and 'In lower pwr state' (yellow). The O-RU7-2 unit is enclosed in a dashed box. It contains several blocks: O-RAN FH (pink), eCPRI (yellow), Digital Processing Unit (green), RF Processing Unit (green), Timing Unit (yellow), and Power Unit (yellow). Arrows show data flow between these units. A 'To/From O-DU7-2' connection is shown on the left. A 'GNSS (optional)' block provides 'Local timing from GNSS or equivalent' to the Timing Unit. The Timing Unit provides 'Local timing from CDR' to the eCPRI, Digital Processing Unit, and RF Processing Unit. The Power Unit provides power to the Timing Unit and the RF Processing Unit.](09bbf29437733f966ca999242382a8fe_img.jpg) + +Figure 4-3: Energy Savings for O-RU Fully Disabled. The diagram shows the internal components of an O-RU7-2 unit. At the top, three colored boxes indicate power states: 'Fully active pwr state' (pink), 'Lowest pwr state' (green), and 'In lower pwr state' (yellow). The O-RU7-2 unit is enclosed in a dashed box. It contains several blocks: O-RAN FH (pink), eCPRI (yellow), Digital Processing Unit (green), RF Processing Unit (green), Timing Unit (yellow), and Power Unit (yellow). Arrows show data flow between these units. A 'To/From O-DU7-2' connection is shown on the left. A 'GNSS (optional)' block provides 'Local timing from GNSS or equivalent' to the Timing Unit. The Timing Unit provides 'Local timing from CDR' to the eCPRI, Digital Processing Unit, and RF Processing Unit. The Power Unit provides power to the Timing Unit and the RF Processing Unit. + +**Figure 4-3: Energy Savings for O-RU Fully Disabled** + +The descriptors “Lowest Power State” and “Lower Power state” relate to the degree of functionality of each sub-block, which corresponds to the level of energy savings possible. Each sub-block will now be discussed: + +- RF Processing Unit.** Since the O-RU is in a state where all carriers for all RATs are disabled, no RF functionality is needed. Thus all RF blocks can be in the lowest power state. Specific supply rails from the Power Unit may potentially be disabled. +- Digital Processing Unit.** In this context, the Digital Processing Unit relates to functionality directly associated with the RF signals, such as DFE, DPD, DDC/DUC, etc. Therefore, it can also be put into the lowest power state. Some supply rails may be disabled, or lowered in voltage to support retention of digital content. +- Power Unit.** As mentioned above, some supply rails can be disabled, or reconfigured to a more efficient mode associated with lower load currents. +- Timing Unit.** Power consumption may be lowered by disabling buffers or PLLs used to generate clocks for the RF Processing and Digital Processing Units. O-RU timing and frequency synchronization, as per IEEE 1588, should still be preserved. +- eCPRI Unit.** C-Plane and U-Plane message handling functionality can be disabled, but M-Plane message processing support will still be needed. +- O-RAN FH.** Some of the fiber link optical modules (e.g., QSFP) can be disabled since user plane data capacity is reduced to zero. The corresponding PHY transceivers that connect to the QSFPs can also be disabled. If instead wired Ethernet links are used instead of fiber, these unneeded Ethernet links can be put into one of the pre-defined Ethernet PHY low power modes. + +The wake-up time for this O-RU\_Full\_Disable state would be the longest of any of the Carrier Disable modes, since all RF-related functionality is disabled; C-Plane message processing may also be disabled. The wake-up time needed to get at least some of the carriers back on the air is expected to take 10s or 100s of msec. + +### 4.2.2 Disabling at least one of the multiple RF bands used at the O-RU site + +In this O-RU\_Band\_Disable scenario, the RF functionality for at least one of the operational bands is disabled. RF traffic on the other operational bands would continue, but it is anticipated that overall user traffic would be less, as this would be the normal pre-condition for disabling one of the RF bands. + +![Figure 4-4: Energy Savings for O-RU Band Disable. The diagram illustrates the power states of an O-RU supporting NR TDD bands n78 and n41. A central yellow box represents the 'Digital Baseband Unit'. To its left, three colored boxes indicate power states: 'Fully active pwr state' (purple), 'Lowest pwr state' (light blue), and 'In lower pwr state' (yellow). The Digital Baseband Unit is connected via 'SERDES' to two RF sections. The top section, labeled 'n78 XCVR', is shaded green and represents the 'Lowest pwr state'. It shows multiple RF chains (RF chain #0 to RF chain #N-1) connected to an antenna module. The bottom section, labeled 'n41 XCVR', is shaded red and represents the 'Fully active pwr state'. It also shows multiple RF chains (RF chain #0 to RF chain #N-1) connected to an antenna module. The diagram demonstrates that the n78 band is disabled during lower traffic scenarios, while the n41 band remains active.](1017e1097a396edb76c81b5143824bca_img.jpg) + +Figure 4-4: Energy Savings for O-RU Band Disable. The diagram illustrates the power states of an O-RU supporting NR TDD bands n78 and n41. A central yellow box represents the 'Digital Baseband Unit'. To its left, three colored boxes indicate power states: 'Fully active pwr state' (purple), 'Lowest pwr state' (light blue), and 'In lower pwr state' (yellow). The Digital Baseband Unit is connected via 'SERDES' to two RF sections. The top section, labeled 'n78 XCVR', is shaded green and represents the 'Lowest pwr state'. It shows multiple RF chains (RF chain #0 to RF chain #N-1) connected to an antenna module. The bottom section, labeled 'n41 XCVR', is shaded red and represents the 'Fully active pwr state'. It also shows multiple RF chains (RF chain #0 to RF chain #N-1) connected to an antenna module. The diagram demonstrates that the n78 band is disabled during lower traffic scenarios, while the n41 band remains active. + +**Figure 4-4: Energy Savings for O-RU Band Disable** + +The diagram above shows one example scenario where, for an O-RU supporting NR TDD bands n78 and n41, one of the bands (n78 in the diagram) is disabled during lower traffic scenario. The architecture shown has dedicated XCVRs for n78 and n41, but it could be one transceiver with only the n78 RF paths disabled. + +In the figure, the n41 XCVR and associated RF front-end is shaded red to indicate full power operation. The n78 RF portion is shaded green to indicate it's in its lowest power state. The Digital Baseband Unit is assumed to be one SOC or board that services both RF bands, and is shaded yellow to indicate it's processing less digital traffic. In another form, there could be separate Digital Baseband Units for each RF band, in which case the n41 Baseband would be shaded red, and the n78 one shaded green. + +The recovery time to bring the disabled RF band back on the air is expected to be 10s of msec, but details depend on what sub-blocks were disabled in the RF XCVR. Data traffic can continue on the operational band, while the other band is being re-activated. + +### 4.2.3 Disabling usage of one or more CCs within a band at the O-RU site. + +In this O-RU\_CC\_disable scenario, the number of active component carriers (CCs) in a band are reduced, but the band still stays in operation. For example, as overall user traffic abates in the evening, the O-RU configuration could be modified to use two 50 MHz CCs instead of four. + +Fully active pwr state + +Lowest pwr state + +In lower pwr state + +![Diagram of O-RU architecture in a fully active state. A Digital Baseband Unit (DBU) is connected via SERDES to an n78 XCVR. The XCVR has multiple TX and RX paths. RF chain #0 and RF chain #3 are shown. RF chain #0 includes an RF PA and LNA. RF chain #3 includes an LNA. The RF chains are connected to MIMO #0 and MIMO #3, which are connected to Antenna or Antenna module. The Antenna module has two CCs (CC #1 and CC #2) and two TXs (TX2 and TX4).](b31f573cd5d4c3d66ddf01df1e8c19b1_img.jpg) + +Diagram of O-RU architecture in a fully active state. A Digital Baseband Unit (DBU) is connected via SERDES to an n78 XCVR. The XCVR has multiple TX and RX paths. RF chain #0 and RF chain #3 are shown. RF chain #0 includes an RF PA and LNA. RF chain #3 includes an LNA. The RF chains are connected to MIMO #0 and MIMO #3, which are connected to Antenna or Antenna module. The Antenna module has two CCs (CC #1 and CC #2) and two TXs (TX2 and TX4). + +RU with CC enable/disable in the same band: 2<sup>nd</sup> CC off + +Fully active pwr state + +Lowest pwr state + +In lower pwr state + +![Diagram of O-RU architecture in a lower power state. The Digital Baseband Unit (DBU) and n78 XCVR are highlighted in yellow, indicating they are in a lower power state. The RF chain #0 and RF chain #3 are shown. RF chain #0 includes an RF PA and LNA. RF chain #3 includes an LNA. The RF chains are connected to MIMO #0 and MIMO #3, which are connected to Antenna or Antenna module. The Antenna module has two CCs (CC #1 and CC #2) and two TXs (TX2 and TX4).](e8183cd54425bfbef32e6bb21c025955_img.jpg) + +Diagram of O-RU architecture in a lower power state. The Digital Baseband Unit (DBU) and n78 XCVR are highlighted in yellow, indicating they are in a lower power state. The RF chain #0 and RF chain #3 are shown. RF chain #0 includes an RF PA and LNA. RF chain #3 includes an LNA. The RF chains are connected to MIMO #0 and MIMO #3, which are connected to Antenna or Antenna module. The Antenna module has two CCs (CC #1 and CC #2) and two TXs (TX2 and TX4). + +**Figure 4-5: Energy Savings for O-RU CC Disable: two CCs active (top figure), and one CC active (bottom)** + +The two figures above show a case where two CCs are used initially, then the O-RU reconfigures to use only one CC when user traffic diminishes. In the top figure, all sub-blocks are operating at the nominal power level required for two CC operation. In the lower figure, the digital baseband and XCVR are in a lower power state, as fewer CCs are being processed. The actual power savings for the digital baseband and XCVR block depend on implementation details such as which sub-component performs CC combining and splitting, whether contiguous or non-contiguous CA is used, etc. + +Note that, in the RF front end diagram in the lower portion, all sub-components are shown as red except for the PA. The other components will draw nearly the same power regardless of how many CCs are being sent. The RF PA, however, would be operating at approximately 3 dB lower output power (in the example above, and assuming full RB allocation for the two CC and one CC cases), so some reduction in energy consumption is expected. + +The recovery time to re-activate the disabled CCs requires further study. A closely related aspect is whether data traffic can continue on the already active CCs while the other CCs are being re-enabled. If so, then more time can be allowed to re-activate the dormant CCs. The details will be implementation dependent. + +## 4.3 RF Channel Reconfiguration Network Energy Savings + +The scope of RF Channel reconfiguration includes following actions + +- (a) O-RU Array Rx/Tx ON/OFF e.g., 64Tx/Rx to 32Tx/Rx +- (b) Modify SU/MU MIMO spatial streams or data layers. +- (c) Modify number of SSB beams. +- (d) Modify O-RU Antenna Transmit power + +In mobile networks mMIMO radio unit has integrated antenna system that offers Single/Multiuser MIMO and beamforming capabilities to enhance cell capacity & throughput. The beamforming is achieved by exciting the array elements with appropriate weights. With this technique multiple uncorrelated beams can be generated, through which multiple data streams can be transmitted/received to/from UE during high-capacity requirement scenarios. In low-capacity scenario, i.e., when the expected traffic volume or number of connected users are lower than the configured threshold, energy savings can be achieved by reducing the power consumption of O-RUs by switching off certain Tx/Rx RF channels that are connected to the respective mMIMO array antenna elements/sub array. For example, 32 out of 64 RF channels connected to Tx/Rx Arrays of an O-RU can be switched off in a digital mMIMO architecture and correspondingly the number of spatial layers and SSBs can be reduced. The procedure (involvement of respective O-RAN interfaces) of the RF Channel Reconfiguration depends on the management architecture model (hybrid or hierarchical) and the deployment option. The off/on switch decision can be made by an AI/ML model within the inference host deployed at the non-RT RIC (denoted as deployment Option 1), or at the Near-RT RIC (denoted as deployment option 2) [11]. Among others the AI/ML models may include prediction of future traffic, user mobility, and resource usage and may also predict expected energy efficiency enhancements, resource usage, and network performance for different ES optimization states. + +The main aim of RF Channel Reconfiguration is to perform O-RU Tx/Rx Array selection. However, Tx/Rx Array reselection may require modifying the maximum number of spatial streams, the number of SSB beams or the O-RU Antenna transmit power. Hence the overall scope of RF Channel Reconfiguration includes the actions listed in Table 4.3-1. + +| Action Name | Explanation | Possible Implementation Method | +|---------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| O-RU Tx/Rx Array selection | O-RU Tx/Rx Array selection means switching off certain Tx/Rx Arrays or Array elements to reduce power consumption of O-RU.<br><br>Reselecting Rx/Tx Arrays may impact cell coverage. | <ul style="list-style-type: none"> <li>– O-RU reports all supported Tx/Rx Array selections to O-DU or to SMO via Open FH M-Plane.</li> <li>– Based on traffic load and user distribution the Non-RT/Near RT RIC will optimize Tx/Rx Array selection.</li> </ul> | +| Modification of number of SU/MU MIMO spatial streams or data layers | The maximum number of spatial streams may depend on the O-RU Tx/Rx Array selection, and it may be necessary | <ul style="list-style-type: none"> <li>– O-RU may report the maximum number of supported spatial streams for each Tx/Rx Array</li> </ul> | + +| | | | +|-----------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>to be modified along with a new Tx/Rx Array selection.</p> <p>A reduction of the number of spatial streams without Tx/Rx Array selection is not excluded as in certain scenarios the energy consumption of O-RU and/or O-DU may be reduced by turning off certain processing units of FPGA/GPUs, by running at a lower clock speed or turning off CPU/GPU cores along with reduced processing requirements.</p> | <p>selection. For example, 16 spatial streams for 64 Tx/Rx and 8 spatial Layers for 32 Tx/Rx.</p> <ul style="list-style-type: none"> <li>– Based on the traffic load and the user distribution the O-RU will be instructed about the maximum number of spatial streams to be used. Hence, the O-RU and/or O-DU may be able turn off certain processing units that would be required to processing a higher number of spatial streams.</li> </ul> | +| Modification of the number of SSB beams | <p>The number of SSB beams may depend on the O-RU Tx/Rx Array selection and the number of spatial streams. Hence it may be necessary to adapt the number of SSB beams.</p> | <ul style="list-style-type: none"> <li>– The number of SSB beams is controlled by the O-DU. Hence the O-DU can be instructed via Non-RT/Near-RT RIC to set the number of SSB beams based on Tx/Rx Array selection.</li> </ul> | +| Modify the O-RU Antenna Transmit power | <p>The maximum O-RU total transmit power may depend upon the O-RU Tx/Rx Array selection; hence it may need to be modified along with Tx/Rx Array selection to compensate for reduced coverage in the downlink.</p> | <ul style="list-style-type: none"> <li>– The O-RU power is configured per Tx Array. Hence, the modification may not be required when changing the O-RU Antenna selection from 64 Tx/Rx to 32 Tx/Rx. However, if possible, O-RU Tx power can be increased to compensate for reduced coverage.</li> </ul> | + +**Table 4-2: Some of the actions of RF Channel Reconfiguration [11]** + +## 4.4 Active Low Power Mode + +Most of the Network Energy Savings mechanisms described so far lead to an explicit or implicit decrease in peak capacity due to the disablement of component carriers, MIMO/mMIMO data layers, number of antenna beams, and RF channel reconfiguration. These mechanisms are justified due to a decrease in network traffic or a change in the network operating environment. Another energy saving method i.e., “Active Low Power mode” can be employed by considering the reduction of the active mode power of the O-RU components, based on determining from network conditions and performance KPIs that such a change will not be deleterious to overall network performance. The rated O-RU traffic capacity would not change as all current active RF chains remain fully functional. Some examples of Active Low Power mode reductions are: + +- (a) Reduce RF transmitter chain power consumption at least in multiple Watts, at the expense of relaxed ACLR, based on determining that nearby channels' performance would not be impacted by such a parametric change in the transmit chain. +- (b) Reduce RF receiver front-end power consumption at least in hundreds of milli Watts, at the expense of relaxed front-end linearity (IP3), based on determining that average RX input levels have decreased. The average RX input levels can decrease due to reduced uplink traffic and/or decreased presence of "rogue" interfering signals. +- (c) Reduce RF receiver power consumption, at the expense of relaxed adjacent channel selectivity (ACS), based on determining that RF blockers are not present in sufficient magnitude to warrant full ACS performance. + +To determine if the RF chain power reductions have network performance impact, data exchange with the upper O-DU and CU layers may be needed. For example, the network would assess whether the O-RU power consumption reduction caused any degradation to the following KPIs, for both DL and UL traffic directions: + +- (a) HARQ retry rates +- (b) Average MCS used +- (c) Average throughput per RB sent +- (d) Average energy per bit, + +If it is determined that these metrics were not impacted in a statistically significant way, then the lower power O-RU mode could be considered safe for continued operation. If, however, a degradation in these metrics was observed, then the RF chain configuration would revert to the full performance/default mode, or an intermediate mode. The KPIs would be assessed independently for UL and DL directions, as the low power modes may be applied separately to the RX and TX signal flows. For an O-RU supporting multiple bands, these Active Low Power mode power reductions can be applied independently to each band. + +The figure below shows the high-level functional block diagram of Active Low Power (ALP) mode implementation. Based on sensing RF and traffic metrics, the O-DU or CU would command the O-RU to enter a lower power mode for the RX or TX paths, or both. Performance data is periodically exchanged between O-RU and CU/DU to assess whether the power reductions negatively impact performance data. Some of the initial measurements to determine if the low power modes could be performed within the O-RU itself, e.g., average RX input power, incidence rate of signal overload events, etc. While normally the O-DU would command the O-RU to enter the Active Low Power mode, the O-RU could potentially engage this mode autonomously. This is certainly true in the case of an integrated O-RU/DU where the combined function box could autonomously determine network impact. + +![Figure 4-6 Active Low Power mode high level functional block diagram. The diagram shows the interaction between O-RU and O-DU/O-CU blocks. O-RU contains RF Front End, XCVR, Digital Processing Unit with Pwr Mgmt Function, and Messaging Function. O-DU/O-CU contains Messaging Function, Power Mgmt Function, and Network Performance Monitoring Function. Data flows include U-Plane data, Control Messages, RF Metrics, Low Pwr Commands, and RF and Network Performance metrics.](23ff155324963d340583876f13f6f472_img.jpg) + +``` + +graph TD + subgraph O_RU [O-RU] + RF_FE[RF Front End] + XCVR[XCVR] + DPU[Digital Processing Unit with Pwr Mgmt Function] + MF_ORU[Messaging Function] + RF_FE --- XCVR + XCVR --- DPU + DPU --- MF_ORU + end + + subgraph O_DU_OC [O-DU/O-CU] + MF_ODU[Messaging Function] + PMF[Power Mgmt Function] + NPMF[Network Performance Monitoring Function] + MF_ODU --- PMF + MF_ODU --- NPMF + end + + Ant1[Antenna or Antenna module] --- RF_FE + Ant2[Antenna or Antenna module] --- RF_FE + + O_RU <-->|U-Plane data| O_DU_OC + O_RU <-->|Control Messages| O_DU_OC + O_RU <-->|RF and Network Performance metrics| O_DU_OC + + DPU -- RF Metrics --> XCVR + XCVR -- Low Pwr Commands --> DPU + +``` + +Figure 4-6 Active Low Power mode high level functional block diagram. The diagram shows the interaction between O-RU and O-DU/O-CU blocks. O-RU contains RF Front End, XCVR, Digital Processing Unit with Pwr Mgmt Function, and Messaging Function. O-DU/O-CU contains Messaging Function, Power Mgmt Function, and Network Performance Monitoring Function. Data flows include U-Plane data, Control Messages, RF Metrics, Low Pwr Commands, and RF and Network Performance metrics. + +**Figure 4-6 Active Low Power mode high level functional block diagram** + +### 4.4.1 Benefit and trade-offs: + +- A significant benefit of Active Low Power mode is that, as the name implies, power is reduced while DL or UL traffic is active. Thus, the power reduction is not directly dependent on decreased user traffic. +- Another benefit is that the network conditions supporting the use of Active Low Power (ALP) mode would be expected to persist for several hours or even days. For example, late at night, the average user traffic would decrease, leading to statistically lower DL and UL RF levels being sent or received. On weekends, smaller “booster cells” associated with downtown business districts would be shut + +down or process much less traffic, potentially allowing ALP mode to be applied during the whole weekend. + +- (c) The decisions process and feedback mechanisms to support ALP mode are very amenable to AI and Machine Learning algorithms, as well as statistical hypothesis testing methods. + +One drawback is that the procedure is somewhat empirical in that any network performance degradation cannot necessarily be predicted in advance. Thus, some short-term network impact could be seen when Active LP mode is first engaged, but the AI/ML “tuning” procedures could prevent this from happening in the long run. Additionally, network simulation models can also be used to predict the likelihood that any O-RU mode change would cause performance degradation. + +## 4.5 TRX Control and Advanced Sleep modes (ASM) + +In initial MVP-C proposals, Advanced Sleep modes were suggested as real-time messages to activate low power modes for durations on the order of multiple frames or slots. As per NES development in WG4, there are now four sleep modes, denoted as SM0, SM1, SM2, and SM3. An O-RU may support all of these sleep modes, a subset, or none at all. + +The O-RAN CUS-plane spec, Rel. 13, incorporates new features and commands enabling TRX Control and Advanced Sleep modes. These were developed in WG4 NES Phase 2 sessions during the period January through July 2023. The released WG4 CUS-plane spec is available at + +<https://orandownloadsweb.azurewebsites.net/specifications> + +The NES ST4 (Section Type 4) commands are issued by the O-DU and processed by the O-RU; the ST8 (Section Type 8) command is sent in the opposite direction. The table below summarizes the salient features of these commands. + +| NES command-Section type | Cmd Scope | Sleep depth options | Sleep Duration | Wake-up time | Comment | +|-------------------------------|----------------------|----------------------|-----------------------------------------------------|---------------------------------------------------------|-----------------------------------------------------------------| +| TRX_control-ST4 | ARRAY | SM0-SM3 <sup>1</sup> | 1 to $(2^{28}-1)$ slots, or Indefinite <sup>2</sup> | 1 to $(2^{32}-1)$ usec for each of SM0-SM3 <sup>3</sup> | | +| Advanced Sleep Mode (ASM)-ST4 | ARRAY, CARRIER, O-RU | SM0-SM3 <sup>1</sup> | 1 to $(2^{28}-1)$ slots, or Indefinite <sup>2</sup> | 1 to $(2^{32}-1)$ usec for each of SM0-SM3 <sup>3</sup> | | +| Ready-ST8 | Any of Above | Any of Above | Any of Above | Any of above | Required only if wake-up time is minimum rather than guaranteed | + +**Table 4-2: WG4 CUS plane command summary table** + +- 1 Note 1: An O-RU may implement any subset of SM0-SM3, including all or none. +- 2 Note 2: An indefinite sleep duration is terminated by a subsequent wake-up command. +- 3 Note 3: Wake-up times are pre-defined, and read from o-ran-module-cap.yang. They can be guaranteed, or minimum. In the latter case, ST8 Ready message is used to tell O-DU that wake-up is complete. + +A brief discussion of the WG4 NES changes, relative to the Rel. 12 CUS-plane spec, is provided below: + +- (A) In section 7.2.9.2.3 of the Rel. 13 CUS-plane spec, the TRX CONTROL Section Type 4 command is defined, with detailed description in sections 7.4.6 and 16.2. This command supports only ARRAY-COMMAND scope. It provides for a portion of the targeted antenna array to be put into one of the four sleep modes described below. +- (B) In section 7.2.9.2.4, the Advanced Sleep Mode (ASM) Section Type 4 command is defined, with detailed description 7.4.6 and 16.3. The scope of an ASM command can be an antenna array (ARRAY-COMMAND scope), an array carrier (CARRIER-COMMAND scope), or the entire O-RU (O-RU-COMMAND scope). +- (C) In section 16.1, a table of four sleep modes SM0-SM3 is shown. These command names apply to both TRX-CONTROL and ASM commands, but the wake-up times will vary depending on the target of the command. Below is the table included in v13 CUS plane spec, section 16.1. + +| | | | | +|--------------------------------------------------------------------------------------------------------------|-------------------------------------|-----------------------------|-------------| +| | <b>TRX CONTROL wake-up duration</b> | <b>ASM wake-up duration</b> | <b>NOTE</b> | +| sleep mode 0 | TRXC-mode0-wake-up-duration | ASM-mode0-wake-up-duration | | +| sleep mode 1 | TRXC-mode1-wake-up-duration | ASM-mode1-wake-up-duration | L | +| sleep mode 2 | TRXC-mode2-wake-up-duration | ASM-mode2-wake-up-duration | M | +| sleep mode 3 | TRXC-mode3-wake-up-duration | ASM-mode3-wake-up-duration | N | +| NOTE: within clause 16 the shorter terms L, M, and N are sometimes used for these durations (either command) | | | | + +**Table 4-3: WG4 CUS plane command Sleep mode wake-up duration table** + +- a. It is required that the wake-up times comply with the following inequality: Sleep Mode 0 wake-up duration $< L < M < N$ . Accordingly, it is expected that, for the same command object, ASM mode 3 saves the most power, and ASM mode 0 saves the least. (This is not a mandatory requirement, however.) + - b. Note that, for any of the four sleep modes, applied as either a TRX\_CONTROL or ASM command, the object of the command (array, carrier, or entire O-RU) will become non-functional and not be able to receive or transmit RF signals. + - c. The amount of power saved in each sleep mode is O-RU implementation dependent. +- (D) The Section Type 8 command “ready” field is used by the O-RU to indicate to the O-DU that the wake-up procedure is completed, in the case where the wake-up time is a minimum, rather than guaranteed. The minimum duration mode may apply for cases where the wake-up time may be extended by the need for perform a sub-system recalibration, e.g., if the temperature varied by a certain amount during the sleep interval. +- (E) In section 16.12, an Emergency wake-up command is defined. This applies when a TRX\_CONTROL or ASM sleep mode command is issued for a defined duration, but the O-DU later determines that it must wake-up the O-RU earlier. In this case, an M-Plane command is issued. + +More details regarding the TRX CONTROL and ASM Sleep mode commands are provided in sections 16.6 through 16.13 of the latest CUS-plane specification. Some practical examples are given in section 16.11. + +# 5 Network Energy Savings KPIs and Figures of Merit + +In section 2.1, the listed references [5], [12], and [13] all describe KPIs relating to Network Energy Efficiency, and associated measurement methods. Generally speaking, the Energy Efficiency equation has the following general form: + +**Equation 5-1:** $\text{Network\_efficiency\_KPI} = (\text{Network\_parameter} / \text{Energy\_Consumption})$ + +where both Network\_parameter and Energy\_Consumption are measured over a prescribed time interval. The convention is that “larger is better”, i.e., the Network\_parameter should be as high as possible with Energy Consumption as low as possible. + +Also, the scope of these energy metrics is typically the entire network, e.g., the gNB, backhaul, core network, and the link from the core network to the Internet or Cloud network. In this report, however, we will focus on KPIs pertaining to the O-RU, whenever possible. (Some KPIs may not be easy to measure at an O-RU level.) + +## 5.1 Discussion of Energy Efficiency KPIs relevant to this NES report. + +In section 5.3 of [13], three mobile network KPIs are discussed, relating to total user data volume, coverage area, and latency. The most direct measure is the KPI relating to data volume: + +**Equation 5-2:** $\text{Data\_energy\_efficiency (DEE)} = (\text{Total\_user\_data\_volume} / \text{Total\_energy\_Consumption}) = (DV_{MN} / EC_{MN})$ where + +DV=User Data Volume (both UL and DL), EC=Energy Consumption, and MN= Mobile Network. + +An O-RU-oriented version of this metric would measure only the O-RU energy consumption as well as the user data passing through the O-RU. While the O-RU energy consumption can easily be measured, it is not as straightforward to measure the O-RU data volume. This would require counting the PDSCH and PUSCH RBs sent, while also knowing the MCS used for each. HARQ retry RBs would also have to be accounted for. + +It is possible to make some reasonable assumptions regarding the HARQ\_retry RBs, as the MCS adjustment procedure in LTE and NR is designed to achieve a certain retry%, e.g., 10%. Regarding the MCS, with an integrated O-DU/O-RU deployment, the user downlink data volume is known since the O-DU function receives the actual user data units (PDUs). Based on these observations, we propose the following O-RU-centric Data Energy Efficiency metric: + +**Equation 5-3:** $\text{Data\_energy\_efficiency\_RU (DEE}_{RU}) = (\text{Total\_num\_PRBs} / \text{Total\_energy\_Consumption}_{RU}) = (PRBV_{RU} / EC_{RU})$ where $PRBV_{RU}$ is the volume of PRBs sent or received by the O-RU in a certain observation interval, and $EC_{RU}$ is the energy consumption of the O-RU in that interval. The correspondence between the PRB volume ( $PRBV_{RU}$ ) and the actual user data will be the subject of further study. + +Another KPI given in [13] is the Latency energy efficiency: + +**Equation 5-4:** Latency\_energy\_efficiency (LEE) = + +$1/(\text{Avg\_end\_to\_end\_latency} * \text{Total\_energy\_Consumption}) = 1/(\text{T}_{e2e} * \text{EC}_{MN})$ where $\text{T}_{e2e}$ is the average latency for user data packets traversing the network from the radio to the Internet. Note that both terms are in the denominator, since these KPIs follow the rule “larger is better”. + +An O-RU-specific version of this metric is proposed: + +**Equation 5-5:** Latency\_energy\_efficiency\_RU ( $\text{LEE}_{RU}$ ) = + +$1/(\text{Avg\_end\_to\_end\_latency}_{RU} * \text{Total\_energy\_Consumption}_{RU}) = 1/(\text{T}_{e2e\_RU} * \text{EC}_{RU})$ where $\text{T}_{e2e\_RU}$ is the average latency for user data packets flowing through the O-RU in a reference observation interval, and $\text{EC}_{RU}$ is the energy consumption of the O-RU in that interval. The O-RU latency in the DL direction would be measured as the latency between when a user PRB arrives over the fiber link, in the form of an O-RAN User Plane data message, to the time that the corresponding RF I/Q data is sent out the TX antenna. Similarly, O-RU latency in the UL direction would be measured as the time between received RF I/Q samples at the antenna to corresponding PRB sent via User Plane message to the fiber. + +**Equation 5-6** DL Energy Efficiency = Total\_RF\_pwr\_into\_antennas/Total\_O-RU\_pwr\_consumption + +which would be measured during symbols where 100% of the RBs are transmitted. The KPI is adopted from the Open RAN MOU requirements [17] as discussed in section 5.2.3. The numerator quantity could be interpreted as the conducted RF power fed to the antenna port, for a BS Type 1-C interface as described in section 4.3.1 of [3], or as radiated power measured at the Radiated Interface Boundary (BS Type 1-H as per 4.3.2 of [3]). + +Measurement of the total RF pwr into the antennas cannot practically be performed during live operation. Therefore, it would either be: + +- (a) measured in a controlled laboratory environment, with the value stored in each O-RU’s non-volatile memory, or +- (b) declared as the rated RF power for the O-RU. A single, fixed number would be used for each O-RU, but it shall be consistent with lab measurements for a sample population of O-RU. + +![Figure 5-1: O-RU diagram showing metrics for E2E latency, PRB count, and power consumption. The diagram illustrates the internal components of an O-RU, including a QSPF/Optical Link, Digital Processing Unit (eCPRI, FFT/iFFT, Beamforming, etc.), RF Transceiver, Timing Unit, Power Monitoring unit, and DC-DC Converters. It shows the flow of I/Q traffic, Rec. CLK, and Power Monitor Data Collection. Key metrics are highlighted: DL Latency = t_RF_out_N - t_QSFP_in_N, t_QSFP_in_N = Time at which Frame N 1st data sample in is seen at fiber link, and t_RF_out_N = Time at which Frame N RF analog starts at antenna out. The diagram also shows a -48V input to the DC-DC Converters and a Rsense resistor for power monitoring.](6c32cdda348b4d6ff667eb4e37d7b143_img.jpg) + +Figure 5-1: O-RU diagram showing metrics for E2E latency, PRB count, and power consumption. The diagram illustrates the internal components of an O-RU, including a QSPF/Optical Link, Digital Processing Unit (eCPRI, FFT/iFFT, Beamforming, etc.), RF Transceiver, Timing Unit, Power Monitoring unit, and DC-DC Converters. It shows the flow of I/Q traffic, Rec. CLK, and Power Monitor Data Collection. Key metrics are highlighted: DL Latency = t\_RF\_out\_N - t\_QSFP\_in\_N, t\_QSFP\_in\_N = Time at which Frame N 1st data sample in is seen at fiber link, and t\_RF\_out\_N = Time at which Frame N RF analog starts at antenna out. The diagram also shows a -48V input to the DC-DC Converters and a Rsense resistor for power monitoring. + +**Figure 5-1: O-RU diagram showing metrics for E2E latency, PRB count, and power consumption** + +In Figure 5-1 above, the relevant O-RU metrics associated with the latency, PRB traffic count, and O-RU power consumption are shown. The figure shows a -48V powered O-RU but alternative sources such as AC + +or +12V supply inputs are possible. The O-RU power consumption can be measured at the -48V input using the power monitoring unit shown above. The DL and UL PRBs could also be monitored via PRB counters in the digital processing unit, or the O-DU could keep a record of allocated DL and UL PRBs. With an integrated O-DU, user data packets could be monitored, which will be a more direct measurement than PRBs. + +While the end-to-end latency (shown above for DL traffic case) is easy to visualize, it may not be easy to measure in practice. More likely it would be characterized by design. + +## 5.2 Discussion of O-RU-specific KPIs relevant to Network energy Savings + +Here we provide a general discussion of the attributes or parameters associated with a given Network Energy saving mechanism. These may or may not impact the energy efficiency metrics discussed in the previous section. + +### 5.2.1 Expected O-RU or O-RU/DU Network energy Savings Percentage + +The basic expectation is that the Network Energy Savings methods described in section 4 all will reduce O-RU power consumption. The amount of savings will be implementation dependent, and O-RU or O-RU/DU vendors can differentiate their offerings by the degree of savings offered. + +Even so, it is useful to state the amount of energy savings or power reduction expected by each method, as a percentage of some reference value of energy or power consumption. + +The Carrier On/Off methods of Section 4.2 and the RF Channel Reconfiguration procedures of Section 4.3 will all reduce the Active mode reference power consumption of the O-RU, which is defined in section 3.1 for TDD mode as the average O-RU or O-RU+DU power for a 75/25 DL/UL symbol ratio, with no symbol gaps other than those needed for UE timing advance. + +The following table summarizes the various Phase 1 Energy Savings mechanisms, and their impact on the O-RU sub-blocks. In the last column, a rough estimate of total O-RU % power savings is offered. + +| NES Mechanism | Traffic Capacity Impact | Wake-up Latency | Traffic Disruption during re-activation of disabled resources | % Energy Savings range vs. Active Mode Ref. Power Consumption | Comment | +|-------------------------|-------------------------|------------------------------|---------------------------------------------------------------|---------------------------------------------------------------|---------| +| All RF carriers shutoff | No user Data traffic | 100s of msec or several secs | N/A (already no traffic) | 80-99% | | + +| | | | | | | +|----------------------------------|--------------------------|----------------------|--------|----------|------------------------------------------------------------------------------------------------------------------------------------------------------| +| RF Band shutoff | Yes <sup>1</sup> | | No | 40-50% | Entire front end for disabled RF band can be put in very low power state | +| CC shutoff within a band | Yes <sup>1</sup> | | FFS | Few % | Limited reduction in RF Front-end power; main power reduction will be via reducing JESD bandwidth and DUC/DDC filtering | +| RX/TX Array order reduction | Some impact <sup>2</sup> | msecs or 10s of msec | Likely | 10s of % | Reducing number of RF front-end chains will directly reduce front-end power, which is dominant power consumer for medium and wide-area base stations | +| Reduced # of MIMO spatial layers | Likely | | | Unclear | Any change in # of antennas required could be offset by need for additional data symbols in time domain | + +**Table 5-1 O-RU NES Mechanisms and their impact** + +Note 1: Traffic capacity impact should be directly related to the amount of RF spectrum removed from service. + +Note 2: Traffic capacity impact depends on specifics of RF array re-configuration, e.g., reduction in # of beams could lead to reduced antenna gain, coverage range and DL/UL MCS utilized. + +### 5.2.2 Diurnal O-RU power calculator + +In references [5] and [15], methods for characterizing an NR FR1 base station power consumption in a defined set of test conditions are given. The base station activity model allows for three different loading states: (a) Low Load, (b) Medium Load, and (c) Busy Hour load. Additionally, as per Annex E of [5], user traffic is represented as a percentage of available PDSCH resources, and PUSCH is not explicitly accounted for. While these procedures are useful for measuring a candidate O-RU in a controlled lab environment, without having to generate simulated UE PRACH or PUSCH traffic, it may not fully represent the real-world network environment. + +For actual network scenarios, we propose an O-RU diurnal energy calculator based on the actual Downlink, Uplink, and SM0-SM3 power state percentages. The general format is shown in the table below. As energy cost per kW-hr may vary versus time of day, it is also shown as a variable. The daily totals of interest will be total energy consumed, and total energy cost. Average time spent in each of the power states can also be computed. This power compute framework has multiple benefits: + +- A. Initially, during O-RU or network development, existing models of network traffic can be used to predict DL and UL percentages, with blank symbol periods then allocated to one of the four Advanced Sleep Modes SM0-SM3. Based on O-RU design targets for the different power states, total daily energy usage can be computed accordingly, along with trade-offs of network latency as a function of each sleep mode. + +- B. Later, in actual deployment, O-RU energy metrics can be captured in real time, along with the power state percentages<sup>1</sup>, and uploaded periodically to the upper network management functions. AI and Machine Learning techniques can be used to tune the network sleep mode behavior so as to minimize total energy cost, while still achieving acceptable network latency, user perceived throughput, and other network performance metrics. + +| Duration | DL % | UL % | SM0 % | SM1 % | SM2% | SM3% | Energy usage (kW-hr) | Energy Cost per kW-Hr | Total Cost | +|-------------|------|------|-------|-------|------|------|----------------------|-----------------------|------------------| +| 00:00-01:00 | | | | | | | | | | +| 01:00-02:00 | | | | | | | | | | +| 02:00-03:00 | | | | | | | | | | +| 03:00-04:00 | | | | | | | | | | +| 04:00-05:00 | | | | | | | | | | +| 05:00-06:00 | | | | | | | | | | +| 06:00-07:00 | | | | | | | | | | +| 07:00-08:00 | | | | | | | | | | +| 08:00-09:00 | | | | | | | | | | +| 09:00-10:00 | | | | | | | | | | +| 10:00-11:00 | | | | | | | | | | +| 11:00-12:00 | | | | | | | | | | +| 12:00-13:00 | | | | | | | | | | +| 13:00-14:00 | | | | | | | | | | +| 14:00-15:00 | | | | | | | | | | +| 15:00-16:00 | | | | | | | | | | +| 16:00-17:00 | | | | | | | | | | +| 17:00-18:00 | | | | | | | | | | +| 18:00-19:00 | | | | | | | | | | +| 20:00-21:00 | | | | | | | | | | +| 21:00-22:00 | | | | | | | | | | +| 22:00-23:00 | | | | | | | | | | +| 23:00-00:00 | | | | | | | | | | +| TOTAL | | | | | | | Total daily energy | | Total daily cost | +| | | | | | | | | | | + +The table above can be enhanced to include other refinements, such as DL and UL PRB utilization percentage for the used PDSCH and PUSCH symbols, PRACH and SRS symbol percentage, # of TRs activated, etc. + +<sup>1</sup> The O-RU energy consumption would be reported by O-RU to O-DU periodically. The O-DU should know the percentages for each power state (DL, UL, SM0-DM3), so the O-RU need not track these. + +### 5.2.3 Open-MOU Energy KPIs and requirements + +The Open RAN MOU group, consisting of five European operators<sup>2</sup>, is not directly affiliated with the O-RAN Alliance. Its members are, however, part of O-RAN and have been working closely with the O-RAN Sustainability Focus Group (SuFG) to promote the Open RAN MOU requirements [1]. In particular, there are nine energy efficiency requirements (rel1\_O-RU\_26 through rel1\_O-RU\_34). + +For example, rel1\_O-RU\_26 reads as follows “Energy Efficiency of RRH in 2T2R / 4T4R / 8T8R configurations shall be at least 40% (with 100% traffic load)”. In discussions with SuFG, it came out that the definition is this KPI is really: + +$$DL\_O-RU\_Energy\_Efficiency = \frac{Total\_RF\_pwr\_into\_antennas}{Total\_O-RU\_pwr\_consumption}$$ + +where the measurement is conducted with 100% of the total DL PRBs for the enabled carriers being transmitted. This KPI is now included in section 5.2.1, but O-RAN WG7 does not mandate any expected efficiency target. + +### 5.2.4 O-RU Power calculation tool + +WG7 has developed an Excel calculation tool to estimate O-RU power consumption, as well as the DL\_Energy\_Efficiency metric cited above. The tool will be located in the ZIP file containing this v2.0 technical report. Some snippets from the tool output are shown below. Some key points: + +1. Normative Reference [16] provides some typical numbers for baseband and e-CPRI blocks, as well as PA output powers. Values similar to these are used in the O-RU Power calculation tool. +2. In the total output power roll-up in the right portion of the tool, for the TX power column, the DL energy efficiency power metric is computed. +3. While some of the detailed parameters such as PA efficiency, LNA power consumption, etc., are aligned with currently available RF Front end components, in no case were vendor power consumption values used literally. +4. The power for the baseband and e-CPRI components will depend on whether an FPGA or a dedicated ASIC is used, with the latter expected to draw less power. + +Most importantly, the tool’s purpose is to allow operators, RAN vendors, or SOC suppliers to estimate total O-RU power consumption and efficiency in different configurations. Each O-RU design will have a unique component set and thus different power consumption. + +--- + +<sup>2</sup> [OpenRAN MoU Group - Telecom Infra Project](#) + +| Parameter | Value | Units | +|--------------------------------|-------------|---------------| +| TX_pwr_per_antenna_mMIMO | 3 | W | +| TX_pwr_per_antenna_Macro | 30 | W | +| Post_PA_filter_IL | 1.5 | dB | +| TX_pwr_per_antenna_dBm | 34.8 | dBm | +| FR1_pwr_per_PA | 36.3 | dBm | +| FR1_PA_eff | 44% | (Module eff.) | +| FR1_PA_pwr_consumption | 9.63 | W | +| FR1_PA_disabled_pwr | 0.06 | W | +| Pre_driver_pwr_consumption | 0.45 | W | +| Pre_driver_Off_pwr_consumption | 0.01 | W | +| LNA_pwr_RX_active | 0.45 | W | +| LNA_pwr_RX_disabled | 0.005 | W | +| XCVR_pwr_per_RX_chain | 0.95 | W | +| XCVR_pwr_per_TX_chain | 0.9 | W | +| eCPRI_fronthaul_IC_pwr | 35 | W | +| L1_BB_DFE_IC_pwr | 100 | W | +| Timing_and_sync_module | 2 | W | +| QSFP_fiber_XCVR | 15 | W | +| UL_duty_cycle | 25% | | +| DL_duty_cycle | 75% | | +| PMU_SW_Eff | 90% | | +| Energy_cost_per_kWh | 0.16 | | +| MIMO_Array_size | 64 | | +| UL_DL_ratio | 0.333333333 | | +| Total radiated power | 52.8 | dBm | + +| Block or IC | Nominal TX Pwr(W)<br>for 64 Antennas | +|----------------------------------------------------------|--------------------------------------| +| RF XCVR | 57.6 | +| RX LNA | 0.32 | +| TX Pre-driver | 28.8 | +| RF PA | 616.4 | +| <b>RF Sub-totals</b> | <b>703.10</b> | +| eCPRI processing (FFT/iFFT/CUS plane) | 35.0 | +| L1 Baseband Processing | 100.0 | +| Timing_and_sync_module | 2.0 | +| QSFP_fiber_XCVR | 15.0 | +| <b>Total_Pwr (W)</b> | <b>855.1</b> | +| <b>Total_Pwr_including DC_DC eff (W) for 64 TR array</b> | <b>950.1</b> | +| <b>DL_Efficiency (Pwr into antenna/Total O_RU pwr)</b> | <b>20.2%</b> | + +# 6 Mapping of low power modes to M-Plane or C-Plane commands + +The Network Energy Savings features described in Section 4 will ultimately be mapped to M-Plane or C-Plane commands in actual implementation. If the commands already exist, then this section will describe a general procedure for using the commands to realize the specific NES low power feature from Section 4. If the commands do not exist, then we discuss the basic requirements of the new command needed for effective NES feature implementation. + +## 6.1 Feature to Command mapping table + +The following table provides a high-level summary of the commands needed for each NES feature. + +| NES Feature | Document section | M-Plane or C-Plane control | Commands exist? | Comment/Follow-up | +|-------------------------------------------|------------------|----------------------------|-----------------|----------------------------------------------------| +| Disabling all RF bands | 4.2.1 | M-Plane | Yes | As per M-Plane section 15.3.2 | +| Disabling one or more bands in an O-RU | 4.2.2 | M-Plane | Yes | As per M-Plane section 15.3.2 | +| Disabling one or more CCs in an O-RU band | 4.2.3 | M-Plane | Yes | As per M-Plane section 15.3.2 | +| RF Channel Reconfiguration | 4.3 | M-Plane, possibly C-Plane | No | WG4 discussion topic <sup>1</sup> | +| Active Low Power Mode | 4.4 | M-Plane | No | M-Plane command proposal pending <sup>1</sup> | +| Advanced Sleep Mode | 4.5 | C-Plane, M-Plane | No | Command formats now in WG4 discussion <sup>1</sup> | + +**Table 6-1 NES features and mapping to M-Plane or C-Plane commands** + +Note 1: Specifically, as of this version 1.00 publication date, command formats for RF Channel Reconfiguration and Advanced Sleep Modes were being discussed in O-RAN WG4. The M-Plane command CR for Active Low Power mode is also pending as of this 1.00 publication date. + +## 6.2 Detailed discussion of command mapping + +Here we discuss the NES features listed above, and the M-Plane or C-Plane commands required to activate each NES mechanism. The discussion will be limited to providing general references to the M-Plane or C-Plane command types involved, rather than outlining a very specific procedure. If in fact there are gaps, i.e., the necessary M-Plane or C-Plane commands do not exist, that is also noted. + +Some of the capabilities referenced below may be optional O-RU features, e.g., the hardware-state feature. The required features will not be referenced explicitly in the NES capability discussion below, but the associated M-Plane or C-Plane sections should be consulted to identify any optional features or capabilities required to realize the NES functionality. + +### 6.2.1 Disabling all RF bands + +The first step is de-activating all the antenna carriers in the O-RU. This is already supported in the M-Plane and Yang model when all carriers, in all bands, have been placed in the inactive state. Section 15.3.2 of the latest M-Plane spec discusses carrier de-activation procedures. Then, via the NETCONF procedures described in M-Plane spec section 9.1.3, the O-RU Controller can place the O-RU into the global SLEEPING power state<sup>3</sup>, where all O-RU functionality not needed for M-Plane support can be disabled. In this state, C-Plane commands to the O-RU cannot be guaranteed to produce a response, as the C-Plane command processor may itself be disabled. + +To bring the O-RU out of the SLEEPING power state, the O-RU Controller can execute the NETCONF procedure to transition the O-RU into the AWAKE power state. + +### 6.2.2 Disabling one or more bands within an O-RU + +This amounts to de-activating all the antenna carriers for a specific RF band, while leaving other bands active. The O-RU is thus still capable of processing user data traffic. The NETCONF client can place all tx-array-carrier and rx-array-carrier elements in the band into either the INACTIVE or SLEEP state, as discussed in M-Plane spec 15.3.2. + +### 6.2.3 Disabling one or more CCs in a band within an O-RU + +This means de-activating one or more antenna carriers within an active RF band, while leaving other carriers within that band active. The O-RU is still capable of processing user data traffic within that band, using the remaining CCs. The NETCONF client can place the unneeded tx-array-carrier and rx-array-carrier elements in the band into either the INACTIVE or SLEEP state, as discussed in M-Plane spec 15.3.2. + +### 6.2.4 RF Channel Reconfiguration + +RF Channel Reconfiguration amounts to de-activating groups of antenna carriers within an array, e.g., reconfiguring an rx or tx array from 64 elements to 32 elements. The purpose of such a reconfiguration may be to reduce the number of spatial streams/data layers, or reduce the number of antenna beams, or reduce the directivity of the existing beams. + +--- + +<sup>3</sup> See Yang module o-ran-hardware.yang + +The capabilities described in M-Plane spec 15.4.2 and 15.4.3 may be used here, but it is unclear if these are sufficient. O-RAN Work Group 4 is evaluating additional CRs that will facilitate RF Channel reconfiguration. + +### 6.2.5 Active Low Power mode + +Active Low Power mode is intended as a persistent low power mode that can be applied to the RX and/or TX sub-components within an active RF band, while RF receive or transmit is occurring. An M-Plane command will be used to enable it, but this command is still to be defined<sup>4</sup>. The scope of the command is expected to be all RX or TX chains within an array, but finer granularity may be possible. + +### 6.2.6 Advanced Sleep mode + +Advanced Sleep mode is intended to put RF and baseband processing chains within the O-RU into a low power state, for durations spanning one or more slots, sub-frames, or frames. The exact format of the Advanced Sleep mode commands is, as of this writing, now being developed in WG4. + +Note that PRB and TX symbol blanking is already described in the C-Plane specification, sections 8.4.2.2 and 8.4.2.3. Additionally, section 7.7.7 SE7 describes how to aggregate multiple endpoints together for transmission blanking for Section type 0. Thus, multiple symbols for multiple endpoints (carriers) can be blanked using existing commands, but only within a slot. + +# --- 7 O-RU Hardware changes required for NES support + +The Network Energy Savings features described in this document may imply changes to the O-RU hardware architecture, and associated firmware, in order to provide an effective low power solution. In this Phase 1 TR, these are discussed at a high level. + +## 7.1 RF Processing Unit changes + +Referencing Figure 4-2, the RF Processing Unit may require the following changes to support significant power reductions: + +- (a) Ability to quickly disable and enable the front-end RF PA, PA driver, and LNA blocks. Typical control interfaces could be GPIO, SPI, I2C or MIPI RFFE. +- (b) Ability to quickly disable and enable the RF transceiver chains that interface to the front end. The transceiver sub-components involved may include the ADCs and DACs, PLLs, mixers, channel filters, DFEs, I/Q interfaces<sup>5</sup>, CPUs, etc. + +## 7.2 Digital Processing Unit and Timing Unit changes + +Referencing Figure 4-2, the Digital Processing Unit and the Timing Unit may require the following changes to support effective power reductions: + +--- + +<sup>4</sup> (As of the publication date of the 1.00 NES specification release) + +<sup>5</sup> I/Q data formats could be based on JESD, UCle, or other formats + +- (a) Ability to quickly disable and enable the Digital Processing Unit sub-components. This may include I/Q interfaces<sup>6</sup>, Beam Forming HW or SW functions, FFT/iFFT HW or SW functions, PRACH processing functions, O-RAN CU-plane processing functions, fiber interfaces, etc. +- (b) Ability to quickly disable and enable the Timing Unit sub-components. This may include PLLs, clock distribution buffers, etc. + +## 7.3 Energy Monitoring HW and data collection + +The M-Plane data object epe-stats includes data fields for voltage, temperature, current, and power<sup>7</sup>. It can represent current/voltage/power for the entire O-RU or a sub-component. Figure 5-1 in section 5.1 shows the presence a power monitoring unit for measuring and recording the input power consumption. Some ICs that may be suitable for such a functionality are listed in Annex A. + +Any power-monitoring chip suitable for O-RU will have an ADC capable of sampling input voltage and current, and computing power consumption. Additionally, digital averaging of voltage/current/power samples is typically provided. + +![Figure 7-1: Power monitoring timing diagram. The diagram shows a timeline of network symbols (S1 to S14) and power-measuring ADC sample intervals. The top timeline shows 'DL Symbols' (red blocks S1-S5), 'Blank Symbols' (green blocks S6-S9), and 'UL Symbols' (orange blocks S10-S14). Above this, 'Slot N' and 'Slot N+1' are indicated. Below the symbol timeline, two timelines for 'Power-measuring ADC sample intervals' are shown: 'ideal' (aligned with symbols) and 'realistic' (misaligned and longer than one symbol).](544fbd27f4f51eeaf9c37e0da29a4851_img.jpg) + +Figure 7-1: Power monitoring timing diagram. The diagram shows a timeline of network symbols (S1 to S14) and power-measuring ADC sample intervals. The top timeline shows 'DL Symbols' (red blocks S1-S5), 'Blank Symbols' (green blocks S6-S9), and 'UL Symbols' (orange blocks S10-S14). Above this, 'Slot N' and 'Slot N+1' are indicated. Below the symbol timeline, two timelines for 'Power-measuring ADC sample intervals' are shown: 'ideal' (aligned with symbols) and 'realistic' (misaligned and longer than one symbol). + +**Figure 7-1: Power monitoring timing** + +The figure above shows an O-RU network traffic pattern example, with the power monitoring IC's ADC sample intervals shown. In the ideal case, we could have the ADC power sampling intervals be aligned in time with network traffic, producing a power reading per symbol, as shown in the second timeline. In practice, the power monitor's ADC timing may not be aligned with network timing, as shown in the bottom timeline, and the sampling intervals may be longer than one symbol or slot. Furthermore, the ADC sample timing may drift over temperature, if not synchronized with network clocks derived via SyncE protocols or other methods. To address this, coarser averaging can be performed, such that O-RU power data records spanning longer intervals, with fewer data points, can be uploaded to the O-DU. For example, a 1 Hz power sampling frequency can be considered, and reports uploaded every hour over M-Plane. If the amount of + +<sup>6</sup> I/Q data formats could be based on JESD, UCle, or other formats + +<sup>7</sup> See M-Plane specification O-RAN.WG4.MP.0-R003-v12.00 or later, section 17.4 and Table B.1-1 + +data per sample is 64 bits, this would result in an hourly data report size (excluding overhead) of $3600 \times 64 / (1024 \times 8) = 28.1$ kBytes. + +To avoid the impact of ADC sample drift, a power monitoring IC that accepts an external clock, derived from network timing, can be used. This ensures that a given number of ADC samples taken by the power monitoring IC always represents the same time interval. + +Generally speaking, if epe-stats based monitoring is implemented in the O-RU, the following operating principles are recommended: + +1. Power monitoring shall be supported for at least the O-RU input power feed. +2. The power monitoring IC sample clock should be synchronized to a clock related to Network timing. +3. No time gaps in the power monitoring shall be allowed. + +### 7.3.1 Exemplary O-RU Power Delivery Network Architecture + +To support O-RU NES monitoring and reporting capabilities, an example O-RU Power Delivery Network (PDN) is shown in Figure 7-2. The Telecom backplane of -48 Volts is used with Input Protection and Hot-swap capability for ease of insertion at the O-RU site. The Power Monitoring of current, voltage and power can be achieved by various methods, including DC-DC Converter, Switched Mode Power Supplies or Low Drop-out regulators with PGOOD (Power Good), IMON (Current Monitoring) and VMON (Voltage Monitoring) capabilities as well as power monitoring and sequencing ICs that individually control the sequencing of O-RU intermediate rails and their various power consumption metrics. The power monitoring information can be communicated back to the system digital processor via GPIO and low pin count communications buses such as PMBus or I2C/SPI. Additionally, support for the O-RU Alarm of a Dying Gasp event, is included in this example hardware design to keep the O-RU power alive long enough for the O-RU to communicate via M-plane that it has experienced a critical power failure. Please see Annex A for a list of possible part numbers to implement NES support. + +![Figure 7-2: Exemplary O-RU Power Delivery Network support NES. This block diagram illustrates the power delivery architecture within an O-RU. It starts with a -48VDC Telecom Backplane connected to an O-RU power connector. The power flows through an Input Protection and Hot Swap module, then through two Power Monitoring DC-DC Converter Modules (one adjustable from -48V to +50V, the other from -48V to +12V). These modules are connected to a Power Monitoring & Sequencing block, which also receives an On/Off push button input. The Power Monitoring & Sequencing block communicates with a Digital Processor via PMBus and provides a Power Good signal. It also controls a BB Radio (Digital Power, Clock Power, Transceiver Power) and a Voltage Regulators block. A Power Hold-up for Dying Gasp IC, connected to Supercaps, provides a 12V backup. The RFFE (Radio Front-End) block receives +48V and provides +50V (RF PAs), +5V Digital, +5V Analog (RF driver amps), and +3.3V (LNAs) via SMPS and Linear LDO regulators. The entire system is monitored and controlled by the Digital Processor via PMBus and GPIO.](5e264ee36b6bd6897c516fcbee35ac54_img.jpg) + +Figure 7-2: Exemplary O-RU Power Delivery Network support NES. This block diagram illustrates the power delivery architecture within an O-RU. It starts with a -48VDC Telecom Backplane connected to an O-RU power connector. The power flows through an Input Protection and Hot Swap module, then through two Power Monitoring DC-DC Converter Modules (one adjustable from -48V to +50V, the other from -48V to +12V). These modules are connected to a Power Monitoring & Sequencing block, which also receives an On/Off push button input. The Power Monitoring & Sequencing block communicates with a Digital Processor via PMBus and provides a Power Good signal. It also controls a BB Radio (Digital Power, Clock Power, Transceiver Power) and a Voltage Regulators block. A Power Hold-up for Dying Gasp IC, connected to Supercaps, provides a 12V backup. The RFFE (Radio Front-End) block receives +48V and provides +50V (RF PAs), +5V Digital, +5V Analog (RF driver amps), and +3.3V (LNAs) via SMPS and Linear LDO regulators. The entire system is monitored and controlled by the Digital Processor via PMBus and GPIO. + +**Figure 7-2: Exemplary O-RU Power Delivery Network support NES** + +### 7.3.2 Exemplary O-RU Temperature Sensor Architecture + +To support environmental O-RU reporting for M-Plane data models such as epe-stats, an example temperature sensing architecture is shown in Figure 7-3. In this example, an eight channel temperature sensor IC with remote diode connected transistors is used to measure the temperature distributed throughout the O-RU in major subsystems such as digital processor, clocks, power delivery network, optical transceiver, DDR and other memories, RF transceiver, and RF Front-End components such as Power Amplifier and Low Noise Amplifiers. Similar to the power monitoring architecture, the temperature is reported back to the O-RU's digital processor via a low pin count communications bus such as SMbus, I2C, or SPI. Please see Annex A for a list of possible part numbers to implement NES support. + +![Exemplary O-RU Temperature Sensor Architecture supporting NES. The diagram shows an 8-channel temperature sensor IC connected to various temperature sources and a digital processor. The sensor has pins for DXP1-DXP8, DXN1-DXN8, OVERT_N, ALERT_N, SMBCLK, SMBDATA, NC, GND, and PAD. It is powered by 3P3V and has a STBY_N pin. Temperature sources include O-RU Processor Temp 1 & 2, TRX Temperature 1 & 2, RFFE Temp, PDN Temp, and Clock Temp. Alerts are sent to the digital processor.](d426e979a1319bcf065ac85080280146_img.jpg) + +**O-RU** + +**8 Channel Temperature Sensor** + +The diagram illustrates the internal architecture of an O-RU temperature sensor. The sensor is an 8-channel IC with the following connections: + +- Temperature Inputs:** + - O-RU Processor Temp 1 and 2 connect to DXP1/DXN1 and DXP2/DXN2. + - TRX Temperature 1 and 2 connect to DXP3/DXN3 and DXP4/DXN4. + - RFFE Temp connects to DXP5/DXN5. + - PDN Temp connects to DXP6/DXN6. + - Clock Temp connects to DXP7/DXN7. + - An additional input connects to DXP8/DXN8. +- Alerts:** + - OVERT\_N outputs Over Temperature Alert 2 (Critical). + - ALERT\_N outputs Over Temperature Alert 1. +- Control and Power:** + - SMBCLK and SMBDATA interface with the digital processor. + - NC (No Connect) pins are present. + - GND and PAD pins are connected to ground. + - IC is powered by 3P3V. + - STBY\_N is connected to 3P3V via a pull-up resistor. + +Exemplary O-RU Temperature Sensor Architecture supporting NES. The diagram shows an 8-channel temperature sensor IC connected to various temperature sources and a digital processor. The sensor has pins for DXP1-DXP8, DXN1-DXN8, OVERT\_N, ALERT\_N, SMBCLK, SMBDATA, NC, GND, and PAD. It is powered by 3P3V and has a STBY\_N pin. Temperature sources include O-RU Processor Temp 1 & 2, TRX Temperature 1 & 2, RFFE Temp, PDN Temp, and Clock Temp. Alerts are sent to the digital processor. + +**Figure 7-3: Exemplary O-RU Temperature Sensor Architecture supporting NES** + +# 8 Annex A: NES-related components for Power Monitoring + +The table below lists some exemplary components that can be considered for O-RU power monitoring. The list is not intended to be complete, and equivalent ICs from other suppliers are likely available. + +| P/N | Description | Comment | +|-------------------------------|----------------------------------------------------------------------------|-------------------------------------------------------------------------------------| +| <b>Analog Devices ADM1075</b> | -48V Power Monitor IC with Hot Swap support | 5 kHz sample rate for input voltage and current; up to 128 readings can be averaged | +| Maxim 78M6613 | Single Phase AC Power Monitor IC | Measures or computes AC voltage, current, line freq, real and reactive power | +| <b>Analog Devices ADM1266</b> | Cascadable Super Sequencer with Margin Control and Fault Recording | Power supply supervision and sequencing up to 17 supplies. | +| <b>Analog Devices LTC3351</b> | Hot Swappable Supercapacitor Charger, Backup Controller and System Monitor | Used to keep O-RU power up while Dying Gasp issued to M-plane. | + +| | | | +|-------------------------------|------------------------------------------------------|----------------------------------------------------| +| <b>Analog Devices LTC2980</b> | Sequence, Trim, Margin, and Supervise Power Supplies | Multi-Channel PMBUS Power System Manager. | +| <b>Flex BMR457 Series</b> | Fully regulated Advanced Bus Converters | Measures and Monitors Current, Voltage, and Power. | +| <b>Analog Devices MAX6581</b> | 8 Channel Temperature Sensor | Temperature Management & Alerts via SMBus. | + +**Table 8-1: Catalog parts for input power monitoring** + +Additional P/Ns will be added if they provide differentiating features. + + + +# 9 Revision history + +| Date | Revision | Description | +|------------|----------|-------------------------------------------| +| 2023.06.13 | 01.00 | Initial release of v1.0 NES specification | +| 2024.07.16 | 02.00 | V2.0. Candidate submission | \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/04c4ef34e9285cdc033e5269fd1a0ea7_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/04c4ef34e9285cdc033e5269fd1a0ea7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9f7229b0f560db37dc268e1ef5b553d7b413c179 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/04c4ef34e9285cdc033e5269fd1a0ea7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:02ba4e8aa2e5df2870f4d747efa71038eb9f8f47ad0bc71b1fbd90581ef5b271 +size 58594 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/094dad3f8ef696b95f2d90ca61e86ac1_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/094dad3f8ef696b95f2d90ca61e86ac1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd794442d9a4f1febd81ff563d192229dbe58086 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/094dad3f8ef696b95f2d90ca61e86ac1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:68a556b3cb8c5426bc2bf8dac9142377a356a2fe50952ef9f2b3ac63f70bb44d +size 34771 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/1b87196438af18f4f6632cf9f9d94a77_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/1b87196438af18f4f6632cf9f9d94a77_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..310e7a732d0626b1e3fed7dbaeedb50df2426b6d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/1b87196438af18f4f6632cf9f9d94a77_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:466df86c8bf9f798c7b448ec80ecfbff0a4b2872984191fef28646c8233c64f4 +size 4585 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/40ca28971bc9eff332c811b98d7cc900_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/40ca28971bc9eff332c811b98d7cc900_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3e319e64a047c51e8058f18806ca89625589994d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/40ca28971bc9eff332c811b98d7cc900_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b0b397331d330ab6cff7f9e4e78f3a3f16938a72d3b0e0c5f229a6a09eaca1eb +size 57941 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/525de5a5dc79680ddba841dac9ee891c_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/525de5a5dc79680ddba841dac9ee891c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e06c744b46951c23ddc0a7d60cf38bd98068235d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/525de5a5dc79680ddba841dac9ee891c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84d8f6b8c49f0b772dcc65644a59676f7d0a076052f00f490118f2a673cc5815 +size 4521 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/52f8d4605a53f295c63485552f52d525_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/52f8d4605a53f295c63485552f52d525_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d798effa9810dc69277f420b0d72c9dbe7107a08 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/52f8d4605a53f295c63485552f52d525_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c0f94e178a59e3f9d1f497b00af86a29bef5c9175fb8b8508c12ccec6fac7f45 +size 4507 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/5592b40b3e7c59505a3f8c76526befde_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/5592b40b3e7c59505a3f8c76526befde_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..001be18692b4b1b96e2f490078c3cb44bedd8082 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/5592b40b3e7c59505a3f8c76526befde_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1a5de59e4a1ddbb17856d76444d363602b5c648cead040bfec4f1d75d03e70b9 +size 59768 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/7a2bf5ddf60590909383dd1576f86a44_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/7a2bf5ddf60590909383dd1576f86a44_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5407ce89c1c6f75b6f49f14d98e0d7fcb1f3ffc5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/7a2bf5ddf60590909383dd1576f86a44_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6a7c150bb53e1c1743c8dc02aabc4df21bce31be98a1bebfff37098db5460cd2 +size 4522 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/7fce7ea492e5d875ee558d2bd644ad35_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/7fce7ea492e5d875ee558d2bd644ad35_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c0960073d87638b006ace264f1a7ac9e5901c247 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/7fce7ea492e5d875ee558d2bd644ad35_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:23aa5146a68d1386c97134233a2a8380c3ae1e2f0391b7165490de2dd7197f73 +size 59480 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/81ccfc16104f8888c7beb656e60ae28e_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/81ccfc16104f8888c7beb656e60ae28e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9fb6dbec4f785a4b021321ed353441e326c40a95 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/81ccfc16104f8888c7beb656e60ae28e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4d8d27d3fc38eed7e57764b3bcc78098e170d4dfb205b14cf9e87db70f7f9ed3 +size 64240 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/9913e0720429849f0080ed2bc7c49ed1_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/9913e0720429849f0080ed2bc7c49ed1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..70e3ffd90ce8d175e2ce81942e224c08736eed47 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/9913e0720429849f0080ed2bc7c49ed1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:51c3bd84e00baaabbd893ddc3b09d350d0425ca52274fa50a8a8a8c9c9177031 +size 4530 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/a0e415f56a96d16300072e699afff1e9_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/a0e415f56a96d16300072e699afff1e9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7ffd0f69a080ad7b4c017fcb7e23bfa54d5ed9df --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/a0e415f56a96d16300072e699afff1e9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1da717c05a7d20f4f3c4f027fd31bdbaf72d2f5e681626132869b95487ccf769 +size 45873 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/aa50a795ea1b4a8d5e2346af8906c880_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/aa50a795ea1b4a8d5e2346af8906c880_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3ad5bb299039b0097c50ee3be30d03dbf02a7643 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/aa50a795ea1b4a8d5e2346af8906c880_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4d1349c333e4daaf8d83d9da0f30f7464f2601a5e23953139ea3c19db3d6a6ef +size 34326 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/b9d855c0756282dc8447d89219e2fdff_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/b9d855c0756282dc8447d89219e2fdff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..55cd2df076a2b4d2940c0240bb08f9e02c0df8d0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/b9d855c0756282dc8447d89219e2fdff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cd27f310c6cb626c0e67a34ca5be6b8e843f2094aa0245878780596adf5f2e51 +size 43309 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/c8e4b1e112f75bbcab4b2d5b7989fc78_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/c8e4b1e112f75bbcab4b2d5b7989fc78_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..33fa7aa7b1e3043750a5b445e51b9399e11b8637 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/c8e4b1e112f75bbcab4b2d5b7989fc78_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dca678bb6a57353e6450d1ed0724f6fb18f6c886994d49d89e47544d801c9998 +size 35934 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/d1d9c6808ec3504a8c9e13f22e38848b_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/d1d9c6808ec3504a8c9e13f22e38848b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8b51ee87d6e2f4ae81d72a3fb6589741750a7fd2 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/d1d9c6808ec3504a8c9e13f22e38848b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aec136d543aecb7294dd60777b55079521d3b77ecb3c4ff1bc622653b916afea +size 4512 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/f466e250d2e264d0c9d7f7cbce7164dc_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/f466e250d2e264d0c9d7f7cbce7164dc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f4563ec0686d503c93f0ecf43bc421b8b3cd006d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/f466e250d2e264d0c9d7f7cbce7164dc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e6522614d9350d7f6a3c8de43209e9a09547ef76344780abcfb4030812b22c3e +size 4520 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/f9a92b57fb95b3b2812e5b2d02b0145b_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/f9a92b57fb95b3b2812e5b2d02b0145b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5d02653fbcf6f5aa7c1bf196eb96b0618f9a84b3 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/f9a92b57fb95b3b2812e5b2d02b0145b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:13ec867e03e33a64892099d5f352d0ee619a4e86a10896098e09023ead2cd83f +size 39780 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/raw.md b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..703328407902a05c5435c822a70e914bea7d245c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00/raw.md @@ -0,0 +1,1074 @@ + + +# **O-RAN White Box Hardware Working Group Outdoor Macrocell Hardware Architecture and Requirements (FR1) Specification** --- + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238, VAT ID DE321720189. + +# Contents + +| | | | | +|----|--------------------------------------------------------------------------------------|--|----| +| 1 | | | | +| 2 | List of figures ..... | | 4 | +| 3 | List of tables ..... | | 4 | +| 4 | Foreword ..... | | 5 | +| 5 | Modal verbs terminology ..... | | 5 | +| 6 | 1. Scope ..... | | 6 | +| 7 | 2. References ..... | | 6 | +| 8 | 2.1 Normative references ..... | | 6 | +| 9 | 2.2 Informative references ..... | | 7 | +| 10 | 3 Definition of terms, symbols and abbreviations ..... | | 7 | +| 11 | 3.1 Terms ..... | | 7 | +| 12 | 3.2 Symbols ..... | | 8 | +| 13 | 3.3 Abbreviations ..... | | 8 | +| 14 | 4 Deployment Scenarios and White Box Base Station Architecture ..... | | 10 | +| 15 | 4.1 Deployment Scenarios ..... | | 10 | +| 16 | 4.2 White Box Base Station Architecture ..... | | 11 | +| 17 | 5 White Box Hardware Architecture ..... | | 12 | +| 18 | 5.1 O-CU Hardware Architecture ..... | | 12 | +| 19 | 5.1.1 O-CU Architecture Diagram ..... | | 12 | +| 20 | 5.1.2 O-CU Functional Module Description ..... | | 12 | +| 21 | 5.1.3 O-CU Interfaces ..... | | 12 | +| 22 | 5.2 O-DU <sub>7-2x</sub> Hardware Architecture when deployed at cell site ..... | | 12 | +| 23 | 5.2.1 O-DU <sub>7-2x</sub> Functional Module Description ..... | | 13 | +| 24 | 5.2.2 O-DU <sub>7-2x</sub> Interfaces ..... | | 14 | +| 25 | 5.3 O-DU <sub>6</sub> Hardware Architecture when deployed at cell site ..... | | 15 | +| 26 | 5.4 O-DU <sub>8</sub> Hardware Architecture when deployed at cell site ..... | | 15 | +| 27 | 5.5 FHM/Switch - Option 7-2x to Option 7-2x Hardware Architecture ..... | | 15 | +| 28 | 5.6 FHM/Switch - Option 6 to Option 6 Hardware Architecture ..... | | 15 | +| 29 | 5.7 FHGW <sub>7-2x->8</sub> - Option 7-2x to Option 8 Hardware Architecture ..... | | 15 | +| 30 | 5.8 FHM/Switch - Option 8 to Option 8 Hardware Architecture ..... | | 15 | +| 31 | 5.9 O-RU <sub>7-2x</sub> Hardware Architecture ..... | | 15 | +| 32 | 5.9.1 O-RU <sub>7-2x</sub> Functional Module Description ..... | | 15 | +| 33 | 5.10 O-RU <sub>6</sub> Hardware Architecture ..... | | 16 | +| 34 | 5.11 O-RU <sub>8</sub> Hardware Architecture ..... | | 16 | +| 35 | 5.12 Integrated gNB-DU Hardware Architecture ..... | | 16 | +| 36 | 5.12.1 O-DU portion Functional Module Description ..... | | 17 | +| 37 | 5.12.2 O-RU Portion of Integrated Reference Design ..... | | 17 | +| 38 | 5.13 mMIMO O-RU <sub>7-2x</sub> Functional Module Description ..... | | 18 | +| 39 | 6 White Box Hardware Requirements ..... | | 20 | +| 40 | 6.1 O-CU Requirements ..... | | 20 | +| 41 | 6.1.1 O-CU Performance ..... | | 20 | +| 42 | 6.1.2 O-CU Interfaces ..... | | 20 | +| 43 | 6.1.3 O-CU Environmental and EMC ..... | | 21 | +| 44 | 6.1.4 O-CU Mechanical, Thermal and Power ..... | | 21 | +| 45 | 6.2 O-DU <sub>x</sub> Common Requirements ..... | | 22 | + +| | | | | +|----|-------|---------------------------------------------------------------|----| +| 1 | 6.2.1 | O-DU <sub>7-2x</sub> Performance..... | 22 | +| 2 | 6.2.2 | O-DU <sub>7-2x</sub> Interfaces..... | 23 | +| 3 | 6.2.3 | O-DU <sub>x</sub> Environmental and EMC ..... | 23 | +| 4 | 6.2.4 | O-DU <sub>x</sub> Mechanical, Thermal and Power ..... | 24 | +| 5 | 6.3 | O-DU <sub>x</sub> Split Option Specific Requirements ..... | 25 | +| 6 | 6.3.1 | O-DU <sub>7-2x</sub> Specific Requirements..... | 25 | +| 7 | 6.3.2 | O-DU <sub>6</sub> Specific Requirements ..... | 25 | +| 8 | 6.3.3 | O-DU <sub>8</sub> Specific Requirements ..... | 25 | +| 9 | 6.4 | O-RU <sub>x</sub> Common Requirements ..... | 25 | +| 10 | 6.4.1 | O-RU <sub>7-2x</sub> Performance..... | 26 | +| 11 | 6.4.2 | O-RU <sub>7-2x</sub> Interfaces ..... | 29 | +| 12 | 6.4.3 | O-RU <sub>7-2x</sub> Environmental and EMC ..... | 30 | +| 13 | 6.4.4 | O-RU <sub>7-2x</sub> Mechanical, Thermal and Power ..... | 31 | +| 14 | 6.5 | O-RU <sub>7-2x</sub> Split Option Specific Requirements ..... | 33 | +| 15 | 6.5.1 | O-RU <sub>7-2x</sub> Specific Requirements ..... | 33 | +| 16 | 6.5.2 | O-RU <sub>6</sub> Specific Requirements ..... | 33 | +| 17 | 6.5.3 | O-RU <sub>8</sub> Specific Requirements ..... | 33 | +| 18 | 6.6 | FHGW/FHM – Common Requirements..... | 34 | +| 19 | 6.7 | FHGW/FHM – Split Option Specific Requirements ..... | 34 | +| 20 | 6.7.1 | FHM/Switch for Split 7-2x, Specific Requirements ..... | 34 | +| 21 | 6.7.2 | FHGW <sub>7-2x>8</sub> Specific Requirements..... | 34 | +| 22 | 6.7.3 | FHM/Switch for Split 8, Specific Requirements..... | 34 | +| 23 | 6.8 | Integrated gNB-DU Requirements ..... | 34 | +| 24 | | History ..... | 35 | +| 25 | | | | +| 26 | | | | +| 27 | | | | +| 28 | | | | +| 29 | | | | +| 30 | | | | +| 31 | | | | +| 32 | | | | +| 33 | | | | +| 34 | | | | +| 35 | | | | +| 36 | | | | +| 37 | | | | +| 38 | | | | +| 39 | | | | +| 40 | | | | +| 41 | | | | + +# List of figures + +| | | +|------------------------------------------------------------------------------------------------------------|----| +| Figure 4.2-1: Outdoor macro-cell architecture with O-DU <sub>7-2x</sub> at cell site and data center ..... | 11 | +| Figure 5.1-1: O-CU Hardware Block Diagram..... | 12 | +| Figure 5.2-1: O-DU <sub>7-2x</sub> with split physical layer function..... | 13 | +| Figure 5.2-2: O-DU <sub>7-2x</sub> Functional Block and Interface Diagram. .... | 14 | +| Figure 5.9-1: Generic O-RU <sub>7-2x</sub> Functional Module Diagram of 4T4R/8T8R..... | 16 | +| Figure 5.12-1: Integrated O-DU & O-RU (gNB-DU) O-RU Split Option 2 Reference Design..... | 16 | +| Figure 5.12-2: Functional Block Diagram for O-DU Portion..... | 17 | +| Figure 5.12-3: Functional Block Diagram for O-RU portion ..... | 18 | +| Figure 5.13-1: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #1 ..... | 19 | +| Figure 5.13-2: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #2..... | 19 | +| Figure 5.13-3: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #4..... | 20 | + +# List of tables + +| | | +|------------------------------------------------------------------------------------|----| +| Table 4.1-1 Deployment scenarios ..... | 10 | +| Table 6.1-1 :O-CU Performance Requirements..... | 20 | +| Table 6.1-2: O-CU Interface Requirements..... | 21 | +| Table 6.1-3: O-CU EMC Requirements ..... | 21 | +| Table 6.1-4: O-CU Mechanical Requirements ..... | 21 | +| Table 6.1-5: O-CU Thermal Requirements ..... | 22 | +| Table 6.2-1: O-DU <sub>7-2x</sub> Performance Requirements..... | 22 | +| Table 6.2-2: O-DU <sub>7-2x</sub> Interface Requirements ..... | 23 | +| Table 6.2-3: O-DU <sub>7-2x</sub> EMC Requirements..... | 23 | +| Table 6.2-4: O-DU <sub>7-2x</sub> Mechanical Requirements ..... | 24 | +| Table 6.2-5: O-DU <sub>7-2x</sub> Thermal Requirements..... | 25 | +| Table 6.4-1: O-RU <sub>7-2x</sub> Performance Requirements..... | 26 | +| Table 6.4-2: O-RU <sub>7-2x</sub> Interface Requirements ..... | 29 | +| Table 6.4-3: O-RU <sub>7-2x</sub> Environmental and EMC Requirements ..... | 30 | +| Table 6.4-4: O-RU <sub>7-2x</sub> Mechanical, Thermal and Power Requirements ..... | 31 | + +# --- Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +--- + +## Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# 1. Scope + +The contents of the present document are subject to continuing work within O-RAN WG7 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +version xx.yy.zz + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. This variable is for internal WG7 use only. + +The present document specifies system requirements and high-level architecture for the Outdoor Macrocell deployment scenario case as specified in the Deployment Scenarios and Base Station Classes document [1]. + +In the main body of this specification (in any “chapter”) the information contained therein is informative, unless explicitly described as normative. Information contained in an “Annex” to this specification is always informative unless otherwise marked as normative. + +# 2. References + +## 2.1 Normative references + +The following referenced documents are necessary for the application of the present document. + +- [1] ORAN-WG7.DSC.0-V04.00 Technical Specification, ‘Deployment Scenarios and Base Station Classes for White Box Hardware’. +- [2] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [3] 3GPP TS 38.104: "NR; Base Station (BS) radio transmission and reception". (Rel-16.3.0) +- [4] ORAN-WG4.CUS.0-R003-v12.00 Technical Specification, “O-RAN Fronthaul Working Group Control, User and Synchronization Plane Specification”. +- [5] Small Cell Forum, SCF222.10.02 5G FAPI: PHY API Specification, [https://scf.io/en/documents/222\\_5G\\_FAPI\\_PHY\\_API\\_Specification.php](https://scf.io/en/documents/222_5G_FAPI_PHY_API_Specification.php) (accessed on March 6, 2024) +- [6] Small Cell Forum, SCF223.10.01 5G FAPI: RF and Digital Frontend Control API, [https://scf.io/en/documents/223\\_5G\\_FAPI\\_RF\\_and\\_Digital\\_Frontend\\_Control\\_API.php](https://scf.io/en/documents/223_5G_FAPI_RF_and_Digital_Frontend_Control_API.php) (accessed on March 6, 2024) +- [7] 3GPP TS 38.113: “NR: Base Station (BS) Electromagnetic Compatibility (EMC) +- [8] O-RAN.WG1.OAD-R003-v09.00 , O-RAN WG1: “O-RAN Architecture Description” - v09.00 +- [9] O-RAN.WG6.CADS-v04.00, O-RAN WG6: “Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN” – v04.00. +- [10] O-RAN.WG4.MP.0-R003-v12.00 Technical Specification, “O-RAN Management Plane Specification” – v12.00. +- [11] O-RAN.TIFG.E2ETSTFWK.0-v01.00 , “O-RAN End-to-End System Testing Framework Specification 1.0 “ – v01.00. + +- [12] O-RAN White Box Hardware Working Group Outdoor Macrocell Hardware Reference Design Specification +- [13] 3GPP TS 36.104: "Evolved Universal Terrestrial Radio Access (E-UTRA); Base Station (BS) radio transmission and reception". (Rel-17.6.0) +- [14] O-RAN.WG11.Security-Requirements-Specification.O-R003-v06.00, O-RAN WG11, "O-RAN Security Requirements Specification 6.0 " – v06.00. +- [15] O-RAN.WG11.Security-Protocols-Specification.O-R003-v06.00, O-RAN WG11, "O-RAN Security Protocols Specifications 6.0", - v06.00. +- [16] O-RAN.WG11.Security-Test-Specifications.O-R003-v04.00, O-RAN WG11, "O-RAN Security Test Specifications 4.0", - v04.00. +- [17] O-RAN.SuFG.CE.-v01.00, O-RAN SuFG, "Circular economy guidelines on network equipment – Technical Report", - v01.00. + +## 2.2 Informative references + +The following referenced documents are not necessary for the application of the present document, but they assist the user with regard to a particular subject area. + +This section intentionally left blank. + +###### --- This section intentionally left blank.3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the terms and definitions given in [2] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in [2]. For the base station classes of Pico, Micro and Macro, the definitions are given in [3]. + +**Carrier Frequency:** Center frequency of the cell. + +**F1 interface:** The standard interface between an O-CU and an O-DU<sub>x</sub> specified in [8]. + +**Integrated architecture:** An architecture wherein the O-RU<sub>x</sub> and O-DU<sub>x</sub> are implemented on one platform. Each O-RU<sub>x</sub> and RF frontend are associated with one O-DU<sub>x</sub> and are connected to O-CU via F1 interface + +**Split architecture:** An architecture wherein the O-RU<sub>x</sub> and O-DU<sub>x</sub> are physically separated from one another. A switch may aggregate multiple O-RU<sub>x</sub> (s) to one O-DU<sub>x</sub>. The O-DU<sub>x</sub>, switch and O-RU<sub>x</sub> (s) are connected by the fronthaul interface as defined in [4]. + +**Transmission Reception Point (TRxP):** Antenna array with one or more antenna elements available to the network located at a specific geographical location for a specific area. + +**Occupied Bandwidth (OBW):** It refers to the bandwidth occupied by the base station when operated, defined by the sum of the active bandwidths of the band allocation(s) operated. As defined by 3GPP TS 34.121 section 5.8, occupied bandwidth is the bandwidth containing 99% of the total integrated power of the transmitted spectrum, centered on the assigned channel frequency. The bandwidth between the 0.5% power frequency points is the occupied bandwidth. + +**Instantaneous Bandwidth (IBW):** It refers to the bandwidth in which all frequency components can be simultaneously analyzed. It is defined by the frequency boundaries of the operating band(s). + +**Frequency Range:** It refers to bandwidth defined by the frequency range within which the Base Station can be operated, defined by the band-pass filter of the BS; e.g., 3.4 – 3.8 GHz (400 MHz) + +**gNB:** A RAN node providing NR user plane and control plane protocol terminations towards the UE, and connected via the NG interface to the 5GC + +**Frequency Band:** A designated frequency range for the operation of the base station and the UE radios. 5G NR frequency bands are divided into two different frequency ranges: Frequency Range 1 (FR1) that mainly includes sub-6GHz frequency bands, some of which are bands traditionally used by previous standards but has been extended to cover potential new spectrum offerings from 410MHz to 7125MHz; Frequency Range 2 (FR2) that includes frequency bands from 24.25 GHz to 52.6 GHz. Bands in this millimeter wave range have shorter range but higher available bandwidth than bands in the FR1. + +**Fronthaul Gateway (FHGW):** A fronthaul gateway is a physical entity that is located between a distributed unit and one or more radio units where it distributes, aggregates, and/or converts fronthaul protocols between the distributed unit and multiple radio units. + +## 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +$N_{RB}$ Transmission bandwidth configuration, expressed in units of resource blocks (for E-UTRA) + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given in [2] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, as in [2]. + +| | | +|------|-----------------------------------------------------------------------------------| +| 7-2x | Fronthaul interface split option as defined by O-RAN WG4, also referred to as 7-2 | +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth-Generation [Mobile Communications] | +| 5GC | 5G Core | +| ACS | Adjacent Channel Selectivity | +| ADC | Analog to Digital Converter | +| AFE | Analog Front End | +| AFU | Antenna Filter Unit | +| BF | Beamforming | +| BMCA | Best Master Clock Algorithm | +| BPSK | Binary Phase Shift Keying | +| BS | Base Station | +| C2C | Chip to Chip Interface | +| CAL | Calibration | +| CFR | Crest Factor Reduction | +| CLK | Clock | +| CPRI | Common Public Radio Interface | +| CU | Central Unit | +| DAC | Digital to Analog Converter | +| DDC | Digital Down Conversion | +| DDR | Double Data Rate | +| DFE | Digital Front End | +| DL | Downlink | +| DPD | Digital Pre-Distortion | +| DSP | Digital Signal Processor | + +| | | | +|----|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | DU | Distributed Unit | +| 2 | DUC | Digital Up Conversion | +| 3 | eCPRI | Enhanced Common Public Radio Interface | +| 4 | EMC | ElectroMagnetic Compatibility | +| 5 | EVM | Error Vector Magnitude | +| 6 | FAPI | Functional Application Platform Interface | +| 7 | FEC | Forward Error Correction | +| 8 | FFT | Fast Fourier Transform | +| 9 | FH | Fronthaul | +| 10 | FHGW | Fronthaul Gateway | +| 11 | FHGW <sub>x→y</sub> | Fronthaul Gateway that can translate FH protocol from an O-DU <sub>x</sub> with split option x to an O-RU <sub>y</sub> with split option y, with currently available option 7-2x→8. | +| 13 | FHM | Fronthaul gateway with no FH protocol translation, supporting an O-DU with split option x and an O-RU with split option x, with currently available options 6→6, 7-2x→7-2x, 8→8 | +| 15 | FPGA | Field Programmable Gate Array | +| 16 | GbE | Gigabit Ethernet | +| 17 | GPP | General Purpose Processor | +| 18 | IEEE | Institute of Electrical and Electronics Engineers | +| 19 | IMD | InterModulation Distortion | +| 20 | IP | Internet Protocol | +| 21 | I/O | Input/Output | +| 22 | JTAG | Joint Test Action Group | +| 23 | L1 | Layer 1, also referred to as PHY or Physical Layer | +| 24 | L2 | Layer 2, also referred to as Data Link layer in OSI model | +| 25 | L3 | Layer 3, also referred to as Network layer in OSI model | +| 26 | LLS | Lower Layer Split | +| 27 | LNA | Low Noise Amplifier | +| 28 | LTE | Long Term Evolution | +| 29 | MAC | Media Access Control | +| 30 | MIMO | Multiple Input Multiple Output | +| 31 | mMIMO | Massive Multiple Input Multiple Output | +| 32 | MCP | Multi-Chip Package | +| 33 | nFAPI | Network Functional Application Platform Interface | +| 34 | NG | Next Generation | +| 35 | NR | New Radio | +| 36 | OAM | Operations, Administrations and Maintenance | +| 37 | O-CU | O-RAN Centralized Unit as defined by O-RAN | +| 38 | O-DU | O-RAN Distributed Unit as defined by O-RAN | +| 39 | O-DU <sub>x</sub> | A specific O-RAN Distributed Unit having fronthaul split option x where x may be 6, 7-2x (as defined by WG4) or 8 | +| 41 | O-RU | O-RAN Radio Unit as defined by O-RAN | +| 42 | O-RU <sub>x</sub> | A specific O-RAN Radio Unit having fronthaul split option x, where x is 6, 7-2x (as defined by WG4) or 8, and which is used in a configuration where the fronthaul interface is the same at the O-DU <sub>x</sub> | +| 45 | PA | Power Amplifier | +| 46 | PCIe | Peripheral Component Interface Express | +| 47 | PDCP | Packet Data Convergence Protocol | +| 48 | PHY | Physical Layer, also referred as L1 | +| 49 | PLL | Phase Locked Loop | +| 50 | POE | Power over Ethernet | +| 51 | QAM | Quadrature Amplitude Modulation | + +| | | | +|----|-------|-----------------------------------------| +| 1 | QPSK | Quadrature Phase Shift Keying | +| 2 | RAN | Radio Access Network | +| 3 | RF | Radio Frequency | +| 4 | RFIC | Radio Frequency Integrated Circuit | +| 5 | RFSoc | Radio Frequency System on Chip | +| 6 | RLC | Radio Link Controller | +| 7 | RRC | Radio Resource Controller | +| 8 | RU | Radio Unit as defined by 3GPP | +| 9 | RX | Receiver | +| 10 | SDU | Service Data Unit | +| 11 | SFP | Small Form-factor Pluggable | +| 12 | SFP+ | Small Form-factor Pluggable Transceiver | +| 13 | SoC | System on Chip | +| 14 | SPI | Serial Peripheral Interface | +| 15 | TR | Technical Report | +| 16 | TS | Technical Specification | +| 17 | TX | Transmitter | +| 18 | UL | Uplink | +| 19 | USB | Universal Serial Bus | +| 20 | WG | Working Group | +| 21 | | | + +# 4 Deployment Scenarios and White Box Base Station Architecture + +This chapter consists of two parts: the deployment scenario and the white box architecture. The deployment scenarios outline more specific functional requirements of the base station. All the reference designs shall meet these requirements in order to comply with O-RAN white box standard. In the white box hardware architecture section, it describes the overall gNB hardware architecture and function partition that meet the design requirements. The details on each of these topics are described in the following sections. + +## 4.1 Deployment Scenarios + +The outdoor macro-cell is the targeted deployment scenario of this specification. The requirements of the outdoor macro-cell base station are listed in the white-box Deployment Scenarios and Base Station Classes document [1]. Some of the key requirements described in that document are highlighted here. + +**Table 4.1-1 Deployment scenarios** + +| Cell type | Outdoor Macro-cell | +|-------------------------|----------------------------------------------------------------------------------------------| +| Frequency Band | FR1 (n26, n29, n41, n66, n70, n71, n77, n78, B1/n1, B3/n3, B7/n7, n78 CEPT <sup>(1)</sup> ). | +| Instantaneous Bandwidth | Up to 205 MHz for FDD<br>Up to 400 MHz for TDD | +| Occupied Bandwidth | Up to 205 MHz for FDD<br>up to 300 MHz for TDD | +| Inter site distance | 0.5 ~ 2 mile(s) | +| Antenna Configuration | 4T4R ~ 64T64R | +| Fronthaul Type | O-RAN FH, Split Option 7-2x<br>CAT-A and CAT-B Radio Units | +| Midhaul | Split Option 2 | + +(\*) n78 CEPT makes reference to an European n78 sub-band (according with ECC Decision (11) 06 and CEPT Report (67)) + +## 4.2 White Box Base Station Architecture + +In general, the base station hardware architecture can be classified when O-DU<sub>7-2x</sub> is at cell site or O-DU<sub>7-2x</sub> is at the data center. In both cases, O-RAN fronthaul split 7-2x and 3GPP standard interface F1 will be used. + +When O-DU<sub>7-2x</sub> is at the cell site, the O-RUs will be connected from a multi-sector cell site to the O-DU<sub>7-2x</sub>. An optional switch/cell site router may be used between cell site O-RUs and O-DU<sub>7-2x</sub> (i.e. Scenario E.1 from WG6). + +When O-DU<sub>7-2x</sub> is at a data center (i.e., the Edge Cloud from [9]), cell site routers/switches will aggregate O-RUs from multiple cell sites to the O-DU<sub>7-2x</sub>. The O-DU<sub>7-2x</sub> will be connected to the O-CU-CP and O-CU-UP in the mid-haul through F1-C and F1-U interface. The O-CU-CP/O-CU-UP can be in a remote data center (i.e. the Regional Cloud in Scenario C from [9]) or, respectively the O-CU-CP/O-CU-UP can be co-located with O-DU<sub>7-2x</sub> in the data center (i.e. the Edge Cloud in Scenario B from [9]). Accordingly, when the O-DU<sub>7-2x</sub> is deployed at a data center site (i.e., on the Edge Cloud, either on a bare-metal machine or as a container/virtual-machine), the servers running the O-DU<sub>7-2x</sub> shall follow the existing and upcoming specifications from O-RAN WG6. The cell site cloud specifications are for further study in WG6. + +The architecture when O-DU<sub>7-2x</sub> is at the cell site is shown in Figure 4.2-1. The O-DU<sub>7-2x</sub> with integrated switch/cell site router is considered for this architecture. + +![Figure 4.2-1: Outdoor macro-cell architecture with O-DU7-2x at cell site and data center. The diagram shows the O-CU (O-CU-CP, O-CU-UP, Connectivity (Ethernet)) connected to the O-DU7-2x (O-DU7-2, Connectivity (Ethernet)) via the F1-C/U Interface. The O-DU7-2x is connected to the FHM/Switch/Router (Optional), which is then connected to the O-RU7-2 (O-RU7-2, O-RU7-2, O-RU7-2) via the O-RAN Fronthaul (Split Option 7-2x).](c8e4b1e112f75bbcab4b2d5b7989fc78_img.jpg) + +``` + +graph LR + subgraph OCU [O-CU] + OCU_CP[O-CU-CP] + OCU_UP[O-CU-UP] + OCU_ETH[Connectivity (Ethernet)] + end + subgraph ODU72 [O-DU7-2] + ODU72_ETH[Connectivity (Ethernet)] + end + subgraph FHM [FHM/Switch/Router (Optional)] + end + subgraph ORU72 [O-RU7-2] + ORU72_1[O-RU7-2] + ORU72_2[O-RU7-2] + ORU72_3[O-RU7-2] + end + + OCU_ETH <--> |F1-C/U Interface| ODU72_ETH + ODU72_ETH <--> FHM + FHM <--> ORU72 + style ORU72 fill:none,stroke:none + +``` + +Figure 4.2-1: Outdoor macro-cell architecture with O-DU7-2x at cell site and data center. The diagram shows the O-CU (O-CU-CP, O-CU-UP, Connectivity (Ethernet)) connected to the O-DU7-2x (O-DU7-2, Connectivity (Ethernet)) via the F1-C/U Interface. The O-DU7-2x is connected to the FHM/Switch/Router (Optional), which is then connected to the O-RU7-2 (O-RU7-2, O-RU7-2, O-RU7-2) via the O-RAN Fronthaul (Split Option 7-2x). + +**Figure 4.2-1: Outdoor macro-cell architecture with O-DU<sub>7-2x</sub> at cell site and data center** + +# 5 White Box Hardware Architecture + +Based on the gNB physical implementation architectures discussed earlier, this chapter provides the architecture, major building blocks and all external/internal interfaces for each whitebox. + +## 5.1 O-CU Hardware Architecture + +In 3GPP system architecture, the gNB Central Unit (CU) communicates with the Distributed Unit (DU) via an F1 interface [8]. This interface has been adopted by O-RAN Alliance for O-CU and O-DU connection. F1 is an IP-based protocol interface. F1 interface is split into F1-C and F1-U interfaces. + +F1-C interface is used for the management of interface setup/configuration, system information, UE context, RRC transfer, paging and warning message transfer. F1-U interface is used for user data transfer and flow control. + +### 5.1.1 O-CU Architecture Diagram + +The O-CU can be implemented with any General-Purpose Processor (GPP) based platform having an optional hardware accelerator block. The O-CU functions can be implemented either on separated hardware platforms or on the same hardware platforms integrated with O-DU<sub>x</sub> functions. In either case, the O-CU hosts L2/L3 functions, whereas O-DU hosts L2/L1 functions which require different CPU, Storage, Acceleration and Networking capabilities. Figure 5.1-1 shows the hardware blocks and interfaces within the O-CU white box. + +![Figure 5.1-1: O-CU Hardware Block Diagram. The diagram shows the internal components of an O-CU white box. A dashed box labeled 'O-CU' encloses three main blocks: 'Ethernet Interface', 'Digital Processing Unit', and 'Hardware Accelerator'. Bidirectional arrows connect 'Ethernet Interface' to 'Digital Processing Unit', and 'Digital Processing Unit' to 'Hardware Accelerator'. An external 'Backhaul (Ethernet or Wireless)' interface connects to the left 'Ethernet Interface' block. Inside the box, an arrow points from the 'Digital Processing Unit' to a second 'Ethernet Interface' block. This second block connects to an external 'F1 Interface (Ethernet)'.](094dad3f8ef696b95f2d90ca61e86ac1_img.jpg) + +Figure 5.1-1: O-CU Hardware Block Diagram. The diagram shows the internal components of an O-CU white box. A dashed box labeled 'O-CU' encloses three main blocks: 'Ethernet Interface', 'Digital Processing Unit', and 'Hardware Accelerator'. Bidirectional arrows connect 'Ethernet Interface' to 'Digital Processing Unit', and 'Digital Processing Unit' to 'Hardware Accelerator'. An external 'Backhaul (Ethernet or Wireless)' interface connects to the left 'Ethernet Interface' block. Inside the box, an arrow points from the 'Digital Processing Unit' to a second 'Ethernet Interface' block. This second block connects to an external 'F1 Interface (Ethernet)'. + +**Figure 5.1-1: O-CU Hardware Block Diagram** + +### 5.1.2 O-CU Functional Module Description + +The O-CU functional architecture comprises Digital Signal Processing, optional HW Acceleration, and Connectivity (GbE) units as well as memory and storage units as shown in Figure 5.1-1 + +### 5.1.3 O-CU Interfaces + +The O-CU interfaces through backhaul with the vEPC or 5GC core network and via F1 interface with the O-DU<sub>7-2x</sub>. The backhaul and the F1 interfaces are typically implemented with GbE transport/connections. + +## 5.2 O-DU<sub>7-2x</sub> Hardware Architecture when deployed at cell site + +Depending on the 3GPP standards and category of the radio unit, the split function blocks within O-DU<sub>7-2x</sub> and O-RU<sub>7-2x</sub> may vary accordingly. The O-RAN fronthaul C/U/S-plane specification [4] provides comprehensive information on this + +topic. The hardware functional partition architecture is shown in Figure 5.2-1. The High-PHY functions in O-DU<sub>7-2x</sub> are run on Digital Processing Unit, Hardware Accelerator, or both. + +![Figure 5.2-1: O-DU7-2x with split physical layer function. The diagram shows the internal architecture of an O-DU7-2x unit. It includes a Hardware Accelerator, a Digital Processing Unit, and two Ethernet Interfaces. The Hardware Accelerator is connected to the Digital Processing Unit. The Digital Processing Unit is connected to both Ethernet Interfaces. One Ethernet Interface is connected to an F1 Interface. The other Ethernet Interface is connected to a Timing and Synchronization (IEEE 1588) block, which is also connected to the Digital Processing Unit. The Timing and Synchronization block is connected to the O-RAN FH Interface. The O-RAN FH Interface is connected to the Low PHY block, which is part of the O-RU7-2x unit. The O-DU7-2x unit is enclosed in a dashed box, and the O-RU7-2x unit is also enclosed in a dashed box.](f9a92b57fb95b3b2812e5b2d02b0145b_img.jpg) + +Figure 5.2-1: O-DU7-2x with split physical layer function. The diagram shows the internal architecture of an O-DU7-2x unit. It includes a Hardware Accelerator, a Digital Processing Unit, and two Ethernet Interfaces. The Hardware Accelerator is connected to the Digital Processing Unit. The Digital Processing Unit is connected to both Ethernet Interfaces. One Ethernet Interface is connected to an F1 Interface. The other Ethernet Interface is connected to a Timing and Synchronization (IEEE 1588) block, which is also connected to the Digital Processing Unit. The Timing and Synchronization block is connected to the O-RAN FH Interface. The O-RAN FH Interface is connected to the Low PHY block, which is part of the O-RU7-2x unit. The O-DU7-2x unit is enclosed in a dashed box, and the O-RU7-2x unit is also enclosed in a dashed box. + +**Figure 5.2-1: O-DU<sub>7-2x</sub> with split physical layer function** + +### 5.2.1 O-DU<sub>7-2x</sub> Functional Module Description + +The choice of O-DU<sub>7-2x</sub> hardware components depends on the product design requirements and is outside the scope of this specification. Their descriptions are as follows: + +#### Digital Processing Unit + +The processing unit can be any GPP, FPGA or digital signal processor (DSP), with I/O chipset. It may also be in the form of System-On-Chip (SOC), or Multi-Chip Package (MCP). + +#### Memory + +DDR memory devices are used to store the runtime data and software for the processing unit. + +#### Flash Memory + +On board non-volatile storage device is used to store the firmware and non-volatile data, such as log data. + +#### Board Management Controller + +The controller is used to manage/control the power and monitors the operational status of the board. + +#### Storage Device + +The storage device such as hard drive is used to store OS, driver and applications software. + +#### Ethernet Controller + +The Ethernet ports transport the fronthaul or backhaul traffic according to the gNB hardware node requirements. The Ethernet device shall support IEEE1588 based timing synchronization. + +#### Hardware Accelerator + +The hardware accelerator is an optional device. For performance improvement, hardware accelerator can be used to process computationally intensive functions (e.g., Forward Error Correction (FEC)) and to offload the processor. + +![Figure 5.2-2: O-DU7-2x Functional Block and Interface Diagram. The diagram shows a central 'Digital Processing Unit' block. On the left, it connects to 'Hardware Accelerator' via PCIe, 'USB Ports' via USB, 'Video Port' via VGA, 'PCIe Slots' via PCIe, 'Serial Ports' via RS232, and 'Timing' via Timing Signal. On the right, it connects to 'DDR RAM' via Memory Channel, 'Flash Memory' via SPI, 'SMBus Port' via SMBus, 'Storage Drives' via SATA, and 'Ethernet Ports' via Ethernet.](b9d855c0756282dc8447d89219e2fdff_img.jpg) + +Figure 5.2-2: O-DU7-2x Functional Block and Interface Diagram. The diagram shows a central 'Digital Processing Unit' block. On the left, it connects to 'Hardware Accelerator' via PCIe, 'USB Ports' via USB, 'Video Port' via VGA, 'PCIe Slots' via PCIe, 'Serial Ports' via RS232, and 'Timing' via Timing Signal. On the right, it connects to 'DDR RAM' via Memory Channel, 'Flash Memory' via SPI, 'SMBus Port' via SMBus, 'Storage Drives' via SATA, and 'Ethernet Ports' via Ethernet. + +**Figure 5.2-2: O-DU<sub>7-2x</sub> Functional Block and Interface Diagram.** + +### 5.2.2 O-DU<sub>7-2x</sub> Interfaces + +The O-DU<sub>7-2x</sub> supported interfaces described below are also shown in Figure 5.2-2 + +#### Memory Channel Interface + +Support DDR4 and later memory interface. + +#### PCIe Interface + +Support for PCIe Gen3 x16 and later interface versions; the bandwidth depends on the use cases, and it can be used to connect an accelerator device or network card. + +#### Ethernet Interfaces + +Supports any one or combination of 1GbE/10GbE/25GbE/40GbE links. + +#### Serial ATA Interface + +SATA3 shall be supported in case of software storage, such as hard drive. + +#### SPI Interface + +The SPI interface connects the processor with flash type of device for firmware. + +#### Video Interface + +Video interface is optional + +#### USB Interface + +Used to connect with local device for debug or on-board firmware update. + +#### Miscellaneous Interface + +Other interfaces that may be needed such as serial port, JTAG, etc. + +## 5.3 O-DU<sub>6</sub> Hardware Architecture when deployed at cell site + +‘This section intentionally left blank’ + +## 5.4 O-DU<sub>8</sub> Hardware Architecture when deployed at cell site + +‘This section intentionally left blank’ + +## 5.5 FHM/Switch - Option 7-2x to Option 7-2x Hardware Architecture + +The FHGW in the case of split option 7-2x to 7-2x is a multiplexer or a switch where the received data packets are distributed among or aggregated from one or more O-RUs and the signaling and management are appropriately routed to or from specific O-RUs. + +## 5.6 FHM/Switch - Option 6 to Option 6 Hardware Architecture + +‘This section intentionally left blank’ + +## 5.7 FHGW<sub>7-2x->8</sub> - Option 7-2x to Option 8 Hardware Architecture + +‘This section intentionally left blank’. Additional details will be provided in a separate document from the fronthaul gateway task group. + +## 5.8 FHM/Switch - Option 8 to Option 8 Hardware Architecture + +‘This section intentionally left blank’. Additional details will be provided in a separate document from the fronthaul gateway task group. + +## 5.9 O-RU<sub>7-2x</sub> Hardware Architecture + +In this section, high level architectures are presented for various O-RU configuration with split 7-2x. The configurations are nTnR O-RU where ‘n’ is commonly considered to be 4 or 8 for O-RU and 32 or 64 for mMIMO O-RU. In Section 5.9.1, a high-level functional block diagram is described for nTnR O-RU. + +### 5.9.1 O-RU<sub>7-2x</sub> Functional Module Description + +In Figure 5.9-1, we illustrate O-RU<sub>7-2x</sub> functional blocks that support O-RAN FH with split option 7-2x. There is at least one interface port which supports all fronthaul interface (for E.g., Optical Interface). For bandwidth reduction, O-RU<sub>7-2x</sub> architecture also supports the optional compression and decompression functions of FH interface. ASIC/FPGA based O-RAN Fronthaul Processing Unit of O-RU<sub>7-2x</sub> will receive the eCPRI packets and perform optical to electrical conversion, decompression, and security aspects according to WG11 specifications. Subsequently, the packets are sent to DFE through packet interface. The DFE block of O-RU<sub>7-2x</sub> is responsible for Low-Phy functions such as FFT/IFFT, CP addition/removal, and PRACH filtering. Additionally, DDC, DUC, CFR and DPD functions are also performed in DFE unit. The ADC and DAC functions are performed in the AFE, which are mixed signal blocks responsible for conversion of data between the digital to analog domains and vice versa. These signals from the AFE are fed to the Tx/Rx chains. The RF Processing /RF Front End Unit consists of an optional frequency converter (mixer), Power Amplifier (PA)/ Low + +Noise Amplifier (LNA) and Tx/Rx filters in N Tx/Rx chains. An antenna module follows that comprises of physical antenna, RF feed distribution/aggregation network, and optionally an antenna calibration network. The timing unit includes any clock and frequency synthesis required as well as other timing and synchronization circuits. The timing unit shall derive timing and synchronization for the O-RU<sub>7-2x</sub> based on the IEEE 1588v2 protocol. In addition, syncE may also be used for timing as defined in O-RAN FH WG4 specifications [4]. + +![Figure 5.9-1: Generic O-RU7-2x Functional Module Diagram of 4T4R/8T8R. The diagram shows a block diagram of the functional modules. On the left, an 'Optical interface to/from O-DU7-2x' connects to the 'ORAN Fronthaul Processing Unit (C, U, S, M plane)', which handles 'eCPRI, (De-) Compression, Optical, Security'. This unit connects via a 'Packet Interface' to the 'Digital Processing Unit' containing 'DFE N x Tx/Rx' (with '(De-) Compression, Low-Phy, DDC, DUC, CFR, DPD') and 'AFE N x Tx/Rx' (with 'ADC, DAC'). The Digital Processing Unit connects via a 'Digital Interface' to the 'AFE'. The AFE connects via an 'RF Interface' to the 'RF Processing unit', which includes 'N x Tx/Rx/ LNA/PA', 'Filter N', and 'Antenna N ports'. The RF Processing unit also includes 'Tx/Rx Reciprocity CAL Option #1, #2'. A 'Timing' block is connected to the Fronthaul, Digital, and RF units. A 'POWER SUPPLY' block is connected to the Fronthaul, Digital, and RF units. An 'Optional Integration' box is shown at the top right.](7fce7ea492e5d875ee558d2bd644ad35_img.jpg) + +Figure 5.9-1: Generic O-RU7-2x Functional Module Diagram of 4T4R/8T8R. The diagram shows a block diagram of the functional modules. On the left, an 'Optical interface to/from O-DU7-2x' connects to the 'ORAN Fronthaul Processing Unit (C, U, S, M plane)', which handles 'eCPRI, (De-) Compression, Optical, Security'. This unit connects via a 'Packet Interface' to the 'Digital Processing Unit' containing 'DFE N x Tx/Rx' (with '(De-) Compression, Low-Phy, DDC, DUC, CFR, DPD') and 'AFE N x Tx/Rx' (with 'ADC, DAC'). The Digital Processing Unit connects via a 'Digital Interface' to the 'AFE'. The AFE connects via an 'RF Interface' to the 'RF Processing unit', which includes 'N x Tx/Rx/ LNA/PA', 'Filter N', and 'Antenna N ports'. The RF Processing unit also includes 'Tx/Rx Reciprocity CAL Option #1, #2'. A 'Timing' block is connected to the Fronthaul, Digital, and RF units. A 'POWER SUPPLY' block is connected to the Fronthaul, Digital, and RF units. An 'Optional Integration' box is shown at the top right. + +Figure 5.9-1: Generic O-RU<sub>7-2x</sub> Functional Module Diagram of 4T4R/8T8R + +## 5.10 O-RU<sub>6</sub> Hardware Architecture + +‘This section intentionally left blank’ + +## 5.11 O-RU<sub>8</sub> Hardware Architecture + +‘This section intentionally left blank’ + +## 5.12 Integrated gNB-DU Hardware Architecture + +The Integrated O-DU & O-RU (O-RU Functional Split 2) is white box hardware is the platform that performs the O-DU functions such as upper L1 and lower L2 (MAC: multiplexing, scheduling, HARQ and RLC: segmentation, re-transmission, re-ordering) functions along with O-RU. The integrated hardware consists of DU & RU in a single box as shown in Figure 5.12-1. The integrated small cell (gNB-DU) shall support split option – 2 F1 Mid-haul interface termination [3GPP] towards gNB-CU and supports FAPI standard logical interface between Layer2 and Layer1 running on different HW options. + +![Figure 5.12-1 Integrated O-DU & O-RU (gNB-DU) O-RU Split Option 2 Reference Design. The diagram shows a block diagram of the integrated gNB-DU. A 'Clock' block is connected to the 'Central Processing Unit' and 'Digital Processing Unit'. The 'Central Processing Unit' connects to an 'Optical Interface' and an 'Ethernet Interface', both of which connect to 'To/From Midhaul O-CU'. The 'Central Processing Unit' also connects to the 'Digital Processing Unit'. The 'Digital Processing Unit' connects to a 'Transceiver' and an 'RF Frontend', both of which are part of the 'RF Processing Unit'. The 'Transceiver' and 'RF Frontend' connect to an 'Antenna Module'. A 'Power Unit' is connected to the Central Processing Unit, Digital Processing Unit, and RF Processing Unit. The 'Power Unit' is also connected to 'Telecom Power Supply'.](a0e415f56a96d16300072e699afff1e9_img.jpg) + +Figure 5.12-1 Integrated O-DU & O-RU (gNB-DU) O-RU Split Option 2 Reference Design. The diagram shows a block diagram of the integrated gNB-DU. A 'Clock' block is connected to the 'Central Processing Unit' and 'Digital Processing Unit'. The 'Central Processing Unit' connects to an 'Optical Interface' and an 'Ethernet Interface', both of which connect to 'To/From Midhaul O-CU'. The 'Central Processing Unit' also connects to the 'Digital Processing Unit'. The 'Digital Processing Unit' connects to a 'Transceiver' and an 'RF Frontend', both of which are part of the 'RF Processing Unit'. The 'Transceiver' and 'RF Frontend' connect to an 'Antenna Module'. A 'Power Unit' is connected to the Central Processing Unit, Digital Processing Unit, and RF Processing Unit. The 'Power Unit' is also connected to 'Telecom Power Supply'. + +Figure 5.12-1 Integrated O-DU & O-RU (gNB-DU) O-RU Split Option 2 Reference Design + +### 5.12.1 O-DU portion Functional Module Description + +In this Integrated architecture, O-DU functions such as upper L1 and lower L2 functions. L2 Chip will be having multiple interface support like DDR4, QSPI, 1G Ethernet, SFP, PCIe, JTAG, UART, EMMC and many more to support number of additional peripherals. The O-DU portion in the integrated architecture shown in Figure 5.12-2 and it depicts the interconnection of the components and external interfaces. O-DU portion is connected to O-RU portion via PCIe interface. + +![Figure 5.12-2 Functional Block Diagram for O-DU Portion](aa50a795ea1b4a8d5e2346af8906c880_img.jpg) + +``` + +graph TD + subgraph O-DU + CS[Clock Synchronizer] --> CPU[CPU Central Processing Unit] + SFP <--> CPU + Ethernet <--> CPU + JTAG <--> CPU + DDR4 <--> CPU + UART <--> CPU + EMMC <--> CPU + PMU[System Management Controller] <--> CPU + PU[Power Unit] --> PMU + subgraph Sensors + TS[Temp Sensor] + PM[Power Monitor] + EEPROM[EEPROM] + end + PMU --- TS + PMU --- PM + PMU --- EEPROM + end + CPU <-->|PCIe Interface| FPGA[To/From FPGA/ASIC] + +``` + +The diagram illustrates the functional block architecture of the O-DU portion. A central CPU Central Processing Unit is connected to various internal components: a Clock Synchronizer, SFP, Ethernet, JTAG, DDR4, UART, EMMC, and a System Management Controller. The System Management Controller is further connected to a Power Unit and sensors including a Temp Sensor, Power Monitor, and EEPROM. The CPU is also connected to an external FPGA/ASIC via a PCIe Interface. + +Figure 5.12-2 Functional Block Diagram for O-DU Portion + +Figure 5.12-2 Functional Block Diagram for O-DU Portion + +### 5.12.2 O-RU Portion of Integrated Reference Design + +In Integrated architecture the O-RU portion contains the Digital Processing Unit Processing Unit, including the Transceiver, RFFE and other RF components, Clock and Synchronization & Power Unit. Digital processing unit is connected to O-DU portion NPU through PCIe interface. + +#### 5.12.2.1 O-RU High-Level Functional Block Diagram + +Figure 5.12-3 is the high-level functional block diagram for O-RU portion in the Integrated architecture. It also highlights the internal/external interfaces that are required. + +![Figure 5.12-3 Functional Block Diagram for O-RU portion. The diagram shows the internal architecture of an O-RU. A central 'FPGA/ASIC Digital Processing Unit' is connected to 'DDR4' and 'FLASH' memory. It interfaces with a 'To/From CPU PCIe Interface' and a 'Clock Synchronizer'. The 'Digital Processing Unit' is connected via 'JESD204B' to an 'RF Transceiver'. The 'RF Transceiver' contains a 'DAC' and an 'ADC'. The 'RF Transceiver' is connected to an 'RF Front-End Unit'. The 'RF Front-End Unit' includes a 'Tx Section' with four parallel paths, each containing a 'BPF' and a 'PA'. The 'Rx Section' has four parallel paths, each containing a 'BPF' and an 'LNA'. The 'Tx Section' and 'Rx Section' are connected to a 'FILTER BANK' which outputs to antennas. A 'Power Unit' is connected to the 'Clock Synchronizer' and the 'RF Front-End Unit'.](81ccfc16104f8888c7beb656e60ae28e_img.jpg) + +Figure 5.12-3 Functional Block Diagram for O-RU portion. The diagram shows the internal architecture of an O-RU. A central 'FPGA/ASIC Digital Processing Unit' is connected to 'DDR4' and 'FLASH' memory. It interfaces with a 'To/From CPU PCIe Interface' and a 'Clock Synchronizer'. The 'Digital Processing Unit' is connected via 'JESD204B' to an 'RF Transceiver'. The 'RF Transceiver' contains a 'DAC' and an 'ADC'. The 'RF Transceiver' is connected to an 'RF Front-End Unit'. The 'RF Front-End Unit' includes a 'Tx Section' with four parallel paths, each containing a 'BPF' and a 'PA'. The 'Rx Section' has four parallel paths, each containing a 'BPF' and an 'LNA'. The 'Tx Section' and 'Rx Section' are connected to a 'FILTER BANK' which outputs to antennas. A 'Power Unit' is connected to the 'Clock Synchronizer' and the 'RF Front-End Unit'. + +Figure 5.12-3 Functional Block Diagram for O-RU portion + +## 5.13 mMIMO O-RU<sub>7-2x</sub> Functional Module Description + +In this section description and diagram for three types of possible NxM mMIMO O-RU High Level System Architecture are provided. mMIMO O-RU<sub>7-2x</sub> can be realized with different high level radio architecture based on various functional splits and interface/interconnects between these functional blocks. + +The level of integration achieved on an SoC for different functional blocks can vary and that in turn can result in different O-RU architecture and the associated interconnects between the functional blocks. + +These functional splits can be realized through three possible configuration O-RU Architecture options as presented in Figures 5.13-1, 5.13-2, and 5.13-3. + +In mMIMO O-RU High Level System Architecture #1 as shown in Figure 5.13-1, eCPRI frame that comes from O-DU<sub>2x</sub> is compressed/decompressed and processed by O-RAN Fronthaul Processing Unit & Beamformer block. Additionally, security compliance may be carried out according to WG11 specifications. Subsequently, Digital Processing Unit that have FPGA/ASIC based DFE module receives the packets from O-RAN Fronthaul Processing Unit & Beamformer block and performs the functionalities such as compression/decompression, Low-Phy, DDC, DUC, CFR, and DPD. The ADC and DAC functions are performed in AFE block. All these three functional blocks can be part of a single SoC or can be split into multiple physical integrated circuits (IC) and connected with digital or packet-based interface. + +The functional block labelled RF Section, consists of an optional frequency converter (mixer), Power Amplifier (PA)/ Low Noise Amplifier (LNA). The filter is the next functional block in the path and is needed for each of the N Tx/Rx paths to meet the emissions in DL and provide the necessary selectivity for UL. The last functional block in the mMIMO RU system is the Antenna. Depending on the power level for each of the Tx chain in a mMIMO system, the filter could be integrated into the RF Section or could be integrated along with the antenna thus making it the AFU. + +In mMIMO O-RU, Tx/Rx reciprocity calibration is one of the important steps for optimal performance. Calibration is required to align the Tx and Rx chains in phase and amplitude. In some implementations, reciprocity calibration requires to implement a dedicated feedback path. Multiple options are possible for the design of such feedback path – the main three options are shown in Figures 5.13-1, 5.13-2, and 5.13-3. The main difference between each of the calibration options is the implementation of the feedback network and where the RF feedback and associated distribution circuitry resides. + +The calibration signal ultimately needs to be relayed back to the AFE, so that the phase and amplitude difference between each of the corresponding Tx-Rx chain and the phase and amplitude differences between the multiple Tx-Rx chains can be estimated and calibrated accurately to ensure uplink and downlink channel reciprocity to enable beamforming. In CAL option #1, the RF feedback and the distribution circuitry resides in the antenna module and all the RF components including the antenna are part of the Tx/Rx reciprocity calibration loop. In CAL option #2, the RF feedback and the distribution circuitry resides in the filter module and all the RF components till the filter module are part of the Tx/Rx reciprocity calibration. In CAL option #3, the RF feedback and the distribution circuitry resides in the RF Section and all the RF components till the RF Section's output in the Tx path and input in the Rx path are part of the Tx/Rx reciprocity calibration. These calibration options (CAL option #1, #2 and #3) can apply to all three mMIMO O-RU architectures in Figures 5.13-1, 5.13-2, and 5.13-3. + +The timing unit includes any clock and frequency synthesis required as well as other timing and synchronization circuits. The Timing Unit shall derive timing and synchronization for the O-RU<sub>7-2x</sub> based on the IEEE 1588v2 protocol. In addition, syncE may also be used for timing as defined in O-RAN FH WG4 specifications [4]. + +![Figure 5.13-1: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #1. This block diagram shows the system architecture for mMIMO O-RU High Level System Architecture #1. It consists of multiple parallel chains (1 to M) for both Tx and Rx. Each chain includes an ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer, a Digital Processing Unit (DFE N x Tx/Rx), an AFE N x Tx/Rx (ADC, DAC), and an RF Processing unit (Tx/Rx Reciprocity CAL Option #1, #2). The RF Processing unit includes an RF section (N x Tx/Rx/ LNA/PA), a Filter N, and an Antenna N ports. The system is connected to an Optical interface to/from O-DU<sub>2x</sub> and a Timing unit. A POWER SUPPLY is shown at the bottom. A dashed box indicates 'Optional integration'.](5592b40b3e7c59505a3f8c76526befde_img.jpg) + +Figure 5.13-1: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #1. This block diagram shows the system architecture for mMIMO O-RU High Level System Architecture #1. It consists of multiple parallel chains (1 to M) for both Tx and Rx. Each chain includes an ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer, a Digital Processing Unit (DFE N x Tx/Rx), an AFE N x Tx/Rx (ADC, DAC), and an RF Processing unit (Tx/Rx Reciprocity CAL Option #1, #2). The RF Processing unit includes an RF section (N x Tx/Rx/ LNA/PA), a Filter N, and an Antenna N ports. The system is connected to an Optical interface to/from O-DU<sub>2x</sub> and a Timing unit. A POWER SUPPLY is shown at the bottom. A dashed box indicates 'Optional integration'. + +**Figure 5.13-1: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #1** + +In mMIMO O-RU High Level System Architecture #2, the operations that are performed in DFE of mMIMO O-RU High Level System Architecture #1 are distributed between the O-RAN Fronthaul Processing Unit & Beamformer and AFE as shown in Figure 5.13-2. In particular, the Low-Phy functions of DFE are performed in the ASIC/FPGA for O-RAN Fronthaul Processing Unit & Beamformer and DDC, DUC, CFR, and DPD blocks of DFE are part of AFE in the RFIC as shown in Figure 5.13-2. The interconnect between the ASIC/FPGA for ORAN Fronthaul Processing Unit & Beamformer. + +![Figure 5.13-2: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #2. This block diagram shows the system architecture for mMIMO O-RU High Level System Architecture #2. It consists of multiple parallel chains (1 to M) for both Tx and Rx. Each chain includes an ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer, a Digital Processing Unit (DFE & AFE N x Tx/Rx), and an RF Processing unit (Tx/Rx Reciprocity CAL Option #1, #2). The RF Processing unit includes an RF section (N x Tx/Rx/ LNA/PA), a Filter N, and an Antenna N ports. The system is connected to an Optical interface to/from O-DU<sub>2x</sub> and a Timing unit. A POWER SUPPLY is shown at the bottom. A dashed box indicates 'Optional integration'.](40ca28971bc9eff332c811b98d7cc900_img.jpg) + +Figure 5.13-2: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #2. This block diagram shows the system architecture for mMIMO O-RU High Level System Architecture #2. It consists of multiple parallel chains (1 to M) for both Tx and Rx. Each chain includes an ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer, a Digital Processing Unit (DFE & AFE N x Tx/Rx), and an RF Processing unit (Tx/Rx Reciprocity CAL Option #1, #2). The RF Processing unit includes an RF section (N x Tx/Rx/ LNA/PA), a Filter N, and an Antenna N ports. The system is connected to an Optical interface to/from O-DU<sub>2x</sub> and a Timing unit. A POWER SUPPLY is shown at the bottom. A dashed box indicates 'Optional integration'. + +**Figure 5.13-2: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #2** + +In mMIMO O-RU High Level System Architecture #3, DFE and AFE functions are combined on a single DFE & AFE functional module as shown in Figure 5.13-3. In this architecture, (De-)Compression, Low-Phy, DDC, DUC, CFR, and DPD are part of same FPGA/ASIC. There is a packet-based interface/interconnect between the O-RAN Fronthaul Processing Unit & Beamformer and the DFE & AFE functional module. These modules can be on a single SoC or can be on different FPGA/ASIC. + +![O-RAN Alliance Logo](1b87196438af18f4f6632cf9f9d94a77_img.jpg) + +O-RAN.WG7.OMAC-HAR.0-v05.00 + +![mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #3](04c4ef34e9285cdc033e5269fd1a0ea7_img.jpg) + +Figure 5.13-3: mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #3 + +mMIMO [NxM]T[NxM]R O-RU High Level System Architecture #3 + +# 6 White Box Hardware Requirements + +This chapter provides the requirements for various white boxes used within the outdoor macro cell base station. These white boxes are O-CU, O-DU<sub>7-2x</sub> and O-RU<sub>7-2x</sub>. The O-CU and O-DU<sub>7-2x</sub> can be implemented in an integrated fashion into one white box hardware or they can be separated. The details of the testing and compliance to these requirements would be taken as part of the TIFG specification [11]. These requirements will be used to define a hardware reference design specification for the outdoor macro cell base station [12]. + +## 6.1 O-CU Requirements + +O-CU requirements are described in the following sections, which include the performance, interface, environmental, EMC, mechanical, thermal and power requirements. + +### 6.1.1 O-CU Performance + +The performance requirements of the O-CU are listed in Table 6.1-1. + +**Table 6.1-1 :O-CU Performance Requirements** + +| Parameter | Requirement | Priority | +|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------| +| Synchronization | <ul style="list-style-type: none"> <li>The solution shall support 1588v2 Synchronization.</li> <li>The solution shall support T-TSC (Telecom Time Slave Clock).</li> </ul> | High | +| Peak Data Rate | Peak data rate shall be calculated as defined in 3GPP TS 38.306 | | +| Latency | Control Plane < 20 ms (def: message1 to message 5)<br>User Plane < 4 ms (def: PDCP SDU → PDCP SDU) | High | + +### 6.1.2 O-CU Interfaces + +The interface requirements of the O-CU are listed in Table 6.1-2 + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 20 + +**Table 6.1-2: O-CU Interface Requirements** + +| Parameter | Requirement | Priority | +|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------| +| Transport Interface | 1/10 GbE F1 Interface to connect with O-DU <sub>7-2x</sub> at cell site or | High | +| | 25 GbE F1 Interface to connect with O-DU <sub>7-2x</sub> at data center | | +| | 1/10 GbE NG interface to connect with 5G core when O-DU <sub>7-2x</sub> is at cell site or<br>25/100 GbE NG interface to connect with 5G core when O-DU <sub>7-2x</sub> is at data center | High | + +### 6.1.3 O-CU Environmental and EMC + +The EMC requirements of the O-CU are listed in Table 6.1-3. + +**Table 6.1-3: O-CU EMC Requirements** + +| Parameter | Requirement | Priority | +|-------------------------------------|---------------------------------------------------------------------------------------------------------------------------------|----------| +| Safety, EMC | The solution shall comply with the requirements of 3GPP TS 38.113 (2017-12R15) [7] for equipment used in telecommunication room | High | +| Safety, EMC | The solution shall be certified for the required regulatory compliance related to EMC and safety | High | +| Safety, Environment and Reliability | The solution shall support Front to Back airflow | High | +| Safety, Environment and Reliability | The solution shall support Front Serviceability | High | +| Safety, Environment and Reliability | The solution should support IP65 rated version (if implemented outdoors). | High | +| Environment | The solution should comply with the requirements of O-RAN SuFG Circular economy guidelines on network equipment [17] | High | + +### 6.1.4 O-CU Mechanical, Thermal and Power + +The mechanical, thermal, and power requirements of the O-CU are listed in Table 6.1-4 and Table 6.1-5. + +**Table 6.1-4: O-CU Mechanical Requirements** + +| Parameter | Requirement | Priority | +|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------| +| Dimension | The solution shall be 1 rack unit in height | High | +| Dimension | The sled shall meet dimensions of 41 mm (Height) x 215 mm (Width) x 427.5 mm (Depth) | High | +| Status Indicator LED | At least include the following status indicators: <ul style="list-style-type: none"> <li>1 LED indicating on/off status of the power supply</li> <li>1 LED indicating on/off status of the transmission link</li> </ul> | High | + +| | | | +|-------------------|-------------------------------------------------------------------------------------------------|------| +| Power Supply | The solution shall support -48V DC power. The tolerance range should be within -42V and -58V DC | High | +| Power Dissipation | The maximum power consumption of the solution in normal conditions shall not exceed 400W | High | +| Power Drain | The solution shall have the ability to reduce the power drain when not at full load | High | + +**Table 6.1-5: O-CU Thermal Requirements** + +| Parameter | Requirement | Priority | +|-----------------------------|---------------------------------------------------------------------------------------------------|----------| +| Environment and Reliability | The solution shall support operating temperature ranges from 0°C to 50°C indoors. | High | +| Environment and Reliability | The solution may have FANs to support temperature requirements. | High | +| Environment and Reliability | The solution should support extended temperature range (-40°C to +65 °C) if implemented outdoors. | Low | + +## 6.2 O-DU<sub>x</sub> Common Requirements + +The common requirements apply to all the O-DU<sub>x</sub> regardless of the split option. However, in this version of the specification, the focus will be on O-DU<sub>7-2x</sub>. If more options get standardized in a future version of this document, some of these common requirements may be moved to the specific sub-sections in section 6.3. + +### 6.2.1 O-DU<sub>7-2x</sub> Performance + +The performance requirements of the O-DU<sub>7-2x</sub> are listed in Table 6.2-1. + +**Table 6.2-1: O-DU<sub>7-2x</sub> Performance Requirements** + +| Parameter | Requirement | Priority | +|----------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------| +| O-DU <sub>7-2x</sub> server Processing | For the O-DU <sub>7-2x</sub> at cell site serving the FDD bands with 4T4R radios, the solution shall support at least 210 MHz in downlink and 105 MHz in uplink<br><br>For the O-DU <sub>7-2x</sub> at data center serving the FDD bands with 4T4R radios, the solution shall support at least 2 x 210 MHz in downlink and 2 x 105 MHz in uplink | High | +| Transmission distance | Directly connected with O-RUs at cell site or Connected with O-RUs 40 km apart | High | +| Synchronization | For O-DU <sub>7-2x</sub> at cell site: <ul style="list-style-type: none"> <li>The solution shall have a built-in GPS receiver for timing that supports PTP distribution compliant to G.8272.</li> <li>The solution shall comply with the following ITU-T specifications for SyncE: <ul style="list-style-type: none"> <li>Definitions: ITU-T G.8260</li> <li>Architecture: ITU-T G.8261</li> </ul> </li> </ul> | | + +| | | | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| | <ul style="list-style-type: none"> <li>○ SSM transport channel and format: ITU-T G.8264</li> <li>○ Clock specifications: ITU-T G.8262 (EEC)</li> <li>○ Functional model and SSM processing: ITU-T G.781</li> <li>• The solution shall support IEEE 1588 Telecom Grand Master (T-TGM) using G8275.1 profile.</li> <li>• The solution shall support T-GM conversion to Telecom Boundary Clock (T-TBC) when GPS is lost.</li> <li>• The solution shall support Telecom Boundary Clock (T-TBC) per ITU-T G.8273.2.</li> <li>• The solution shall meet 4 hour holdover time of frequency, time/phase.</li> <li>• The solution shall comply with input and output jitter and wander requirements specified in ITU-T G.8262 (for EEC).</li> <li>• For timing synchronization, the solution shall support ORAN LLS-C1/C2 configuration.</li> <li>• The solution shall support alternate BMCA specified in G.8275.1</li> </ul> | | +| Synchronization | For O-DU <sub>7-2x</sub> at data center: <ul style="list-style-type: none"> <li>• For timing synchronization, the solution shall support ORAN LLS- C3 configuration.</li> <li>• The solution shall support T-TSC.</li> </ul> | High | +| Peak Rate | Peak data rate to be calculated based on the formula provided in 3GPP TS 38.306 | High | +| Modulation | DL: QPSK, 16QAM, 64QAM, 256QAM, (1024 QAM desired)<br>UL: $\pi/2$ -BPSK, QPSK, 16QAM, 64QAM (256QAM/1024 QAM desired) | High | +| Latency | Up to 200 us fronthaul latency | High | + +### 6.2.2 O-DU<sub>7-2x</sub> Interfaces + +The interface requirements of the O-DU<sub>7-2x</sub> are listed in Table 6.2-. + +**Table 6.2-2: O-DU<sub>7-2x</sub> Interface Requirements** + +| Parameter | Requirement | Priority | +|---------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------| +| Transport Interface | Fronthaul interfaces connected with either radio unit or fronthaul gateway | High | +| | At least one NG interface to 5GC | High | +| | At least one 1/10 GbE F1 Interface to connect with O-DU <sub>7-2x</sub> at cell site or<br>25 GbE F1 Interface to connect with O-DU <sub>7-2x</sub> at data center | High | + +### 6.2.3 O-DU<sub>x</sub> Environmental and EMC + +The EMC requirements of the O-DU<sub>7-2x</sub> are listed in Table 6.2-3. + +**Table 6.2-3: O-DU<sub>7-2x</sub> EMC Requirements** + +| Parameter | Requirement | Priority | +|-------------|---------------------------------------------------------------------------------------------------------------------------------|----------| +| Safety, EMC | The solution shall comply with the requirements of 3GPP TS 38.113 (2017-12R15) [7] for equipment used in telecommunication room | High | +| Safety, EMC | The solution shall be certified for the required regulatory compliance related to EMC and safety | High | + +| | | | +|-------------------------------------|----------------------------------------------------------------------------------------------------------------------|------| +| Safety, Environment and Reliability | The solution shall support Front to Back airflow | High | +| Safety, Environment and Reliability | The solution shall support Front Serviceability | High | +| Safety, Environment and Reliability | The solution should support IP65 rated version. (if implemented outdoors) | High | +| Environment | The solution should comply with the requirements of O-RAN SuFG Circular economy guidelines on network equipment [17] | High | + +### 6.2.4 O-DU<sub>x</sub> Mechanical, Thermal and Power + +The mechanical and power requirements of the O-DU<sub>7-2x</sub> are listed in Table 6.2-4. + +**Table 6.2-4: O-DU<sub>7-2x</sub> Mechanical Requirements** + +| Parameter | Requirement | Priority | +|----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------| +| Dimension | The solution shall be 1 rack unit in height | High | +| Dimension | For the O-DU <sub>7-2x</sub> at cell site, the solution dimensions shall not exceed 19 inch width and 18 inch depth<br><br>For the O-DU <sub>7-2x</sub> at data center, the sled shall meet dimensions of 41 mm (Height) x 215 mm (Width) x 427.5 mm (Depth) | High | +| Dimension | The solution shall have PCIe Gen 3/4 x16 low profile or half-length slot to add to support FEC Accelerator | High | +| Dimension | The solution shall support a minimum of 64 GB DDR4 or better DRAM using all available DIMM slots to maximize memory bandwidth. 8 DIMM slots are preferred. | High | +| Dimension | The solution shall have at least 2x 240GB SSD drives | High | +| Dimension | For the O-DU <sub>7-2x</sub> at the cell site, the solution with minimum 16 Core and clock speed of 2.3 GHz is recommended. Equivalent/higher alternative processor technology and core counts including combinations of CPUs, GPUs, FPGAs and ASICs and clock frequencies are acceptable.<br><br>For the O-DU <sub>7-2x</sub> at the data center, the solution with minimum 24 Core and clock speed of 2.4 GHz is recommended. Equivalent/higher alternative processor technology and core counts including combinations of CPUs, GPUs, FPGAs and ASICs and clock frequencies are acceptable. | High | +| Dimension | For the O-DU <sub>7-2x</sub> at the cell site, the solution shall have at least 6x 10G ports to carry eCPRI ORAN 7-2x fronthaul traffic from O-RUs to the O-DU <sub>7-2x</sub><br>For the O-DU <sub>7-2x</sub> at the data center, the solution shall have at least 4x 25G ports to carry eCPRI fronthaul and midhaul traffic | High | +| Dimension | For the O-DU <sub>7-2x</sub> at the cell site, the solution shall have 2x 1/10G ports to carry ORAN Split 2 midhaul traffic from O-DU <sub>7-2x</sub> to O-CU | High | +| Status Indicator LED | At least include the following status indicators: <ul style="list-style-type: none"> <li>1 LED indicating on/off status of the power supply</li> <li>1 LED indicating on/off status of the transmission link</li> </ul> | High | + +| | | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| Power Supply | For the O-DU <sub>7-2x</sub> at the cell site, the solution shall have a single DC power supply.<br>For the O-DU <sub>7-2x</sub> at the data center, the solution shall have a single AC/DC power supply.<br><br>The solution shall support -48V DC power. The tolerance range should be within -42V and -58V DC | High | +| Power Dissipation | The maximum power consumption of the solution in normal conditions shall not exceed 400W | High | +| Power Drain | The solution shall have the ability to reduce the power drain when not at full load | High | + +The thermal requirements of the O-DU<sub>7-2x</sub> are listed in Table 6.2-5. + +**Table 6.2-5: O-DU<sub>7-2x</sub> Thermal Requirements** + +| Parameter | Requirement | Priority | +|-----------------------------|--------------------------------------------------------------------------------------------------------------------|----------| +| Environment and Reliability | The solution shall support operating temperature ranges from 0°C to 50°C for data center. | High | +| Environment and Reliability | The solution may have FANs to support temperature requirements. | High | +| Environment and Reliability | The solution should support extended temperature range (-40°C to +55°C) if implemented outdoors. | Low | +| Environment and Reliability | The solution shall support in-band Redfish Chassis management | High | +| Environment and Reliability | The solution shall have at least 4 dry contact inputs and ability for environmental and cabinet alarms monitoring. | High | + +## 6.3 O-DU<sub>x</sub> Split Option Specific Requirements + +### 6.3.1 O-DU<sub>7-2x</sub> Specific Requirements + +‘This section intentionally left blank’. + +### 6.3.2 O-DU<sub>6</sub> Specific Requirements + +‘This section intentionally left blank’. + +### 6.3.3 O-DU<sub>8</sub> Specific Requirements + +‘This section intentionally left blank’. + +## 6.4 O-RU<sub>x</sub> Common Requirements + +The common requirements apply to all the O-RU<sub>x</sub> regardless of the split option. However, in this version of the specification, the focus will be on O-RU<sub>7-2x</sub>. If more options get standardized in a future version of this document, some of these common requirements may be moved to the specific sub-sections in section 6.5. + +In the outdoor environment, the O-RU<sub>7-2x</sub> hardware is placed on the rooftop, pole or wall of the coverage building; it converts the baseband signals to RF signals for transmission over the air or vice versa. All radio requirements are subject to local regulatory limits, where applicable. + +### 6.4.1 O-RU<sub>7-2x</sub> Performance + +The O-RU<sub>7-2x</sub> performance requirements cover all the aspects of radio unit including frequency bands, antenna configurations, power efficiency, etc. Table 6.4-1 lists the performance parameters related to O-RU<sub>7-2x</sub>. + +**Table 6.4-1: O-RU<sub>7-2x</sub> Performance Requirements** + +| Parameter | Requirement | Priority | +|-------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------| +| Operating band | B1/n1, B3/n3, B7/n7, n26, n29, n66, n70, n71, n77, n78, n78 European sub band (3400-3800 MHz according with ECC Decision (11)06 and CEPT Report 67).<br><br>All the bands according to 3GPP TS 36.104 [13] and 3GPP TS 38.104 [3] except n78 European sub-band. | High | +| Bandwidth | The IBW of the n66 O-RU <sub>7-2x</sub> shall be 90 MHz<br><br>The OBW of the n66 O-RU <sub>7-2x</sub> shall be 90MHz. | High | +| | The DL IBW of the n70 O-RU <sub>7-2x</sub> shall be 25MHz, and its UL IBW shall be 15MHz.<br><br>The DL OBW of the n70 O-RU <sub>7-2x</sub> shall be 25MHz, and its UL OBW shall be 15MHz. | | +| | The IBW of the n26 O-RU <sub>7-2x</sub> shall be 7MHz.<br><br>The OBW of the n26 O-RU <sub>7-2x</sub> shall be 7MHz. | | +| | The IBW of the n29 O-RU <sub>7-2x</sub> shall be 11MHz.<br><br>The OBW of the n29 O-RU <sub>7-2x</sub> shall be 11MHz. | | +| | The IBW of the n71 O-RU <sub>7-2x</sub> shall be 35MHz.<br><br>The OBW of the n71 O-RU <sub>7-2x</sub> shall be 35MHz. | | +| | The IBW of the n77 O-RU <sub>7-2x</sub> shall be 280MHz.<br><br>The OBW of the n77 O-RU <sub>7-2x</sub> shall be 200MHz. | | +| | The IBW of n78 O-RU <sub>7-2x</sub> shall be 400MHz.<br><br>The OBW of n78 O-RU <sub>7-2x</sub> shall be up to 300MHz. | | +| | The IBW of B1/n1 O-RU <sub>7-2x</sub> shall be 60MHz.<br><br>The OBW of B1/n1 O-RU <sub>7-2x</sub> shall be 60MHz. | | +| | The IBW of B3/n3 O-RU <sub>7-2x</sub> shall be 75MHz.<br><br>The OBW of B3/n3 O-RU <sub>7-2x</sub> shall be 75MHz. | | +| | The IBW of B7/n7 O-RU <sub>7-2x</sub> shall be 70MHz.<br><br>The OBW of B7/n7 O-RU <sub>7-2x</sub> shall be 70MHz. | | +| | | | +| | | | +| O-RU <sub>7-2x</sub> Multi-band operation | Tri-band: n26+n29+n71<br><br>The O-RU <sub>7-2x</sub> shall have at least 4 RF ports, with n71, n29, and n26 sharing the same RF ports.<br><br>Tri-band: B1/n1+B3/n3+B7/n7 | High | + +| | | | +|--------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| | The O-RU <sub>7-2x</sub> shall have at least 4 RF ports, with B1/n1, B3/n3, and B7/n7 sharing the same RF ports. | | +| | <p>Dual-band: n66+n70</p> <p>The O-RU<sub>7-2x</sub> shall have at least 4 RF ports, with n66 and n70 sharing the same RF ports.</p> <p>Dual-band: B1/n1+B3/n3</p> <p>The O-RU<sub>7-2x</sub> shall have at least 4 RF ports, with B1/n1 and B3/n3 sharing the same RF ports.</p> <p>Dual-band: B1/n1+B7/n7</p> <p>The O-RU<sub>7-2x</sub> shall have at least 4 RF ports, with B1/n1 and B7/n7 sharing the same RF ports.</p> | High | +| Expected Multi-mode and Transceiver Configuration (Number of Transmit/Receive Paths) | Tri-band (n26+n29+n71): 4T4R<br><br>Tri-band (B1/n1+B3/n3+B7/n7): 4T4R | High | +| | Dual-band (n66+n70): 4T4R<br><br>Dual-band (B1/n1+B3/n3 or B3/n3+B7/n7): 4T4R | High | +| | Single-band (n77): 8T8R | High | +| | Single-band (n77): 64T64R | High | +| | Single-band (n78): 32T32R and 64T64R | High | +| | Single-band (B1/n1 or B3/n3 or B7/n7): 4T4R | High | +| Output Power Accuracy | The EIRP/output power of the O-RU <sub>7-2x</sub> shall follow 3GPP TS38.141-1 and TS38-141-2 requirements for normal and extreme conditions as well as for radiated and conducted tests. (It is desirable to remain within +/- 1dB of the set power under all operation condition.) | High | +| TX off Power Level | Less than -85 dBm/MHz (-89 dBm/MHz desired) per antenna connector or TAB connector as per 3GPP TS 38.104 [3] | High | +| EVM at maximum output power | <p>64QAM: EVM smaller than 8% (5% desired)</p> <p>256QAM: EVM smaller than 3.5%</p> <p>For other modulations, refer to 3GPP TS 38.104 [3]</p> | High | +| Operating band unwanted emissions | The operating band unwanted emissions must satisfy the Category B limit defined by the section 6.6.4 in 3GPP TS 38.104 [3]. | High | +| Transmitter spurious emissions | The Operating band unwanted emissions must satisfy the Category B limit defined by the section 6.6.5 in 3GPP TS 38.104 [3]. | High | +| Noise Figure | O-RU <sub>7-2x</sub> receiver Uplink Noise Figure shall be better than 1.9dB typical (average value in normal conditions), 2.5dB Max (worst case conditions) for single-band, dual-band and tri-band. For massive MIMO, the noise figure requirement shall be lower than 3.5 dB | High | +| Rx sensitivity | The throughput shall be $\geq 95\%$ of the maximum throughput of the reference measurement channel as specified in annex A.1 with parameters specified in 3GPP TS 38.104 table 7.2.2-1 for Wide Area BS. | High | + +| | | | +|----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| Blocking | In channel selection, ACS, In-band blocking, out-band blocking, IMD and other receiver specification must follow the 3GPP guidelines for the reference sensitivity is allowed to degrade at most 6 dB under all scenarios of interference signal and corresponding level, as per table 7.4.1.2-1 of [3]. | High | +| Other specifications | Except for all the RF specifications listed above, other RF specifications must follow the requirement in [3]. | High | +| Modulation Mode | DL: QPSK, 16QAM, 64QAM, 256QAM, (1024 QAM desired)<br>UL: $\pi/2$ -BPSK, QPSK, 16QAM, 64QAM (256QAM/1024 QAM desired) | High | +| Min. Output power | The tri-band O-RU <sub>7-2x</sub> (n26+n29+n71):<br><br>4T4R - n26 shall be 10W per port<br><br>4T4R - n29 shall be 40W per port<br><br>4T4R - n71 shall be 30W per port<br><br>The tri-band O-RU <sub>7-2x</sub> (B1/n1+B3/n3+B7/n7):<br><br>4T4R – B1/n1 shall be 40W per port<br><br>4T4R – B3/n3 shall be 40W per port<br><br>4T4R – B7/n7 shall be 40W per port | High | +| | The dual-band O-RU <sub>7-2x</sub> (n66+n70): The combined output power shall be at least 80W per port, under all operating conditions.<br><br>The O-RU <sub>7-2x</sub> shall be able to allocate higher power level for n66 (example: 60W) and lower power level for n70 (example: 20W). The power setting shall be configurable by the operator.<br><br>The dual-band O-RU <sub>7-2x</sub> (B1/n1+B3/n3 or B1/n1+B7/n7): The combined output power shall be at least 80W per port, under all operating conditions.<br><br>The O-RU <sub>7-2x</sub> shall support equal power allocation between bands and preferably should be able to allocate higher power level for B1/n1 (example: 60W) and lower power level for B3/n3 or B7/n3 (example: 20W) and vice versa. The power setting shall be configurable by the operator. | High | +| | Single band O-RU <sub>7-2x</sub> (n77):<br><br>- 8T8R: 40W per port<br><br>- 64T64R: 80dBm EIRP (integrated antenna)<br><br>Single band O-RU <sub>7-2x</sub> (B1/n1 or B3/n3):<br><br>- 4T4R: 40W per port<br><br>Single band O-RU <sub>7-2x</sub> (B7/n7):<br><br>- 4T4R: 60W per port | High | +| | For any Wide band O-RU <sub>7-2x</sub> (n78) product (32T32R and 64T64R) the EIRP shall be (for narrow beam at boresight; assuming SU-MIMO; no power sharing between beams): > +78 dBm (Typically 55 dBm output power + 23 dBi) | High | +| | | | +| Regulation | For n26 band, the O-RU <sub>7-2x</sub> shall have a feature limiting its TX power and meet FCC rules on output power as outlined in part 90 and part 22. | High | +| EIRP Stability | The EIRP/output power of the O-RU <sub>7-2x</sub> shall follow 3GPP TS38.141-1 and TS38-141-2 requirements for normal and extreme conditions as well as for radiated and conducted tests. (It is desirable to remain within +/- 1dB of the set power under all operation condition.) | High | + +| | | | +|--------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| <b>Synchronization</b> | The O-RU <sub>7-2x</sub> shall support GPS and/or IEEE 1588v2 for timing synchronization based on O-RAN CUS plane specification [4]. | High | +| | The O-RU <sub>7-2x</sub> shall support Telecom Slave Clock (T-TSC) to the protocol(s) as defined for the fronthaul interface. Furthermore, the O-RU <sub>7-2x</sub> shall provide additional noise filtering to filter fronthaul interface dynamic noise which will help meeting 3GPP frequency accuracy requirement | High | +| | For timing synchronization, the O-RU <sub>7-2x</sub> shall support the mandatory configurations as defined by O-RAN WG4 specification [4] | High | +| <b>Optical Interface</b> | For 4T4R radios:<br><ul style="list-style-type: none"> <li>- For n66, n70, n26, n29, n71 radios: At least one SFP 10G interface.</li> <li>- For B1/n1, B3/n3 and B7/n7: At least 2x10Gbps SFP+.</li> </ul> | High | +| | For any M-MIMO products the minimum number of Front haul Interface PHY ports should be 2x25Gpps, with SFP28 optical connectors, although 4x25Gbps SFP28 should be needed depending on TRx configuration, IBW, OccBW, total number of carriers supported; DL/UL MU_MIMO paired layers supported, etc. | High | +| <b>Beamforming support (for massive MIMO radios)</b> | Number of Beams: Up to 8 SSB beams (FR1) | High | +| | <b>32T32R:</b><br><br>Horizontal plane: at least $\pm 45$ degrees ( $\pm 60$ degrees desirable) with side lobes suppression > 10dB (>15 dB desirable).<br><br><b>64T64R:</b><br><br>Horizontal plane: at least $\pm 45$ degrees ( $\pm 60$ degrees desirable) with side lobes suppression > 10dB (>15 dB desirable). | High | +| | <b>32T32R:</b><br><br>Vertical plane: At least $\pm 5$ degrees with side lobes suppression > 6dB (>10 dB desirable)<br><br>At least $\pm 2$ degrees with side lobes suppression > 10dB (>15 dB desirable)<br><br><b>64T64R:</b><br><br>Vertical plane: At least $\pm 15$ degrees with side lobes suppression > 6dB (>10 dB desirable)<br><br>At least $\pm 10$ degrees with side lobes suppression > 10dB (>15 dB desirable) | High | +| <b>Antenna elements</b> | For M-MIMO products n78 or any subsets inside this band, the minimum number of single polarization antenna elements must be 192: (12 rows x8 columns x 2 dual slant cross polar antenna elements). | High | +| <b>AAU Number of simultaneous TX user beams/layers per carrier</b> | 16DL and 8UL | High | + +### 6.4.2 O-RU<sub>7-2x</sub> Interfaces + +The interface related requirements of the O-RU<sub>7-2x</sub> are listed in Table 6.4-2. + +**Table 6.4-2: O-RU<sub>7-2x</sub> Interface Requirements** + +| Parameter | Requirement | Priority | +|-----------|-------------|----------| +|-----------|-------------|----------| + +| | | | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall be compliant to O-RAN CUS plane specification [4] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall be compliant to O-RAN M-plane specification [10] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall comply to M-Plane IOT Profile 1 specified in O-RAN M-plane specification [10] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support at least one of the following NETCONF/YANG based models for management plane as specified in O-RAN M-plane specification [10]:<br>(a) hierarchical architecture model<br>(b) hybrid architecture model | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support direct connection between O-RU <sub>7-2x</sub> and O-DU <sub>7-2x</sub> for fronthaul synchronization as specified in O-RAN CUS plane specification [4] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support LLS-C2 and LLS-C3 bridged connection between O-RU <sub>7-2x</sub> and O-DU <sub>7-2x</sub> for fronthaul synchronization as specified in O-RAN CUS plane specification [4]. | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall comply to all the test cases specified in O-RAN IOT specification [11] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support Block floating point compression as specified in O-RAN CUS plane specification [4]. The compression bits shall be configurable through EMS. | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support Pre-configured Transport Delay Method as specified in O-RAN CUS plane specification [4] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support transmission blanking as specified in O-RAN CUS plane specification [4] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support the counters specified in O-RAN CUS plane specification [4] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support the eCPRI header format, section type and section extension type messages as specified in O-RAN CUS plane specification [4] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support G.8275.1 synchronization as specified in O-RAN CUS plane specification [4] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support G.8275.2 synchronization as specified in O-RAN CUS plane specification [4] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall support IEEE 1914.3, ITU-T G.826x, G.827x series specified in O-RAN CUS plane specification [4] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall be compliant to security requirements specifications in accordance with WG11 technical specifications [14] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall be compliant to security protocol specifications in accordance with WG11 technical specifications [15] | High | +| Fronthaul interface | The O-RU <sub>7-2x</sub> shall be compliant to security test specifications in accordance with WG11 technical specifications [16] | High | + +### 6.4.3 O-RU<sub>7-2x</sub> Environmental and EMC + +The environmental and EMC requirements of the O-RU<sub>7-2x</sub> are listed in Table 6.4-3. + +**Table 6.4-3: O-RU<sub>7-2x</sub> Environmental and EMC Requirements** + +| Parameter | Requirement | Priority | +|------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------| +| Mounting method | Back of antenna, Tower, Roof top, Pole, or Wall | High | +| RF Connector | RF connector type should be 4.3-10 female. Location should be on the bottom of O-RU <sub>7-2x</sub> , on left side of connector panel arranged in a single 1x4 row and dimensioned from the backside face. | High | +| AISG Connector | AISG Connector should be standard 8 pin female connector. Location should be on the bottom of O-RU <sub>7-2x</sub> and dimensioned from the backside face. | High | +| RET Connector | O-RU <sub>7-2x</sub> shall provide direct support of antenna Remote Electrical Tilt via a specific port for RET: DIN-8 RET, AISG 2.0. This port shall be located down of the unit. | High | +| Optical Connector | Optical Connector should be SFP+/SFP28. Location should be on the bottom of the O-RU <sub>7-2x</sub> and dimensioned from the backside face. | High | +| Power Connector | Power connector should be: DC Circular Connector, Receptacle, 2-Pin Male. Location should be on the bottom of O-RU <sub>7-2x</sub> and dimensioned from the backside face. Also, connector should be located on the far-right side of connector panel to allow ease of installation | High | +| Lightning Protection | O-RU <sub>7-2x</sub> shall have lightning protection | High | +| Grounding | The O-RU <sub>7-2x</sub> shall support grounding. Ground connector should be a two-wire ground lug. Grounding lug location should be on the bottom of the O-RU <sub>7-2x</sub> and dimensioned from the backside face | High | +| EMC, Safety, Storage, and Transportation | The O-RU <sub>7-2x</sub> shall comply to the following EMC, Safety, Storage, and Transportation Requirements: CFR 47, Part 1.130, Part 15B, UL 62368-1, UL 50E, UL 60950-22, 3GPP 38.113, ETSI EN 300 019-2-4, Severity class 1, Telcordia GR-63, Zone4, Telcordia GR 487, Telcordia GR 63, ETSI 300 019-1-1 Class 1.3, and IEC-61000-4-5, ETSI EN 301 489-1, 3GPP TS 37.113, 3GPP TS 37.114, Directive 2002/95/EC & Directive 2011/65/EU, Directive 2002/96/EC, EU Radio Equipment Directive (RED) 2014/53/EU, ETSI EN 300 019-1-2, Class 2.3, ETSI EN300019-1-1 V2.1.4 (2003-04) Class 1.2: "Weather protected, not temperature-controlled storage locations", ETSI EN 300 019-1-3, class 3.2 (indoor site), ETSI EN 300 019-1-4, class 4.1 (outdoor site). | High | +| Environment | The solution should comply with the requirements of O-RAN SuFG Circular economy guidelines on network equipment [17] | High | + +### 6.4.4 O-RU<sub>7-2x</sub> Mechanical, Thermal and Power + +The mechanical, thermal and power requirements of the O-RU<sub>7-2x</sub> are listed in Table 6.4-4. + +**Table 6.4-4: O-RU<sub>7-2x</sub> Mechanical, Thermal and Power Requirements** + +| Parameter | Requirement | Priority | +|---------------------------------|------------------------------------------------------------------------------------------|----------| +| Weight (excluding mounting kit) | The weight of the tri-band O-RU <sub>7-2x</sub> (n26+n29+n71) shall be less than 35kg. | High | +| | The weight of the dual-band O-RU <sub>7-2x</sub> (n66+n70) shall be less than 30kg. | High | +| | The weight of the single band 64T64R O-RU <sub>7-2x</sub> (n77) shall be less than 50kg | High | +| | The weight of the single band 8T8R O-RU <sub>7-2x</sub> (n77) shall be less than 33kg | High | +| | The weight of the single band 32T32R O-RU <sub>7-2x</sub> (n78) shall be less than 30kg | High | +| | The weight of the single band 64T64R O-RU <sub>7-2x</sub> (n78) shall be less than 40 kg | | + +| | | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| | The weight of the single band 4T4R O-RU <sub>7-2x</sub> (B1/n1 or B3/n3) shall be less than 16kg | High | +| | The weight of the single band 4T4R O-RU <sub>7-2x</sub> (B7/n7) shall be less than 18kg | High | +| | The weight of the dual band 4T4R O-RU <sub>7-2x</sub> (B1/n1+B3/n3 or B3/n3+B7/n7) shall be less than 33kg | High | +| | The weight of the tri-band 4T4R O-RU <sub>7-2x</sub> (B1/n1+B3/n3+B7/n7) shall be less than 35kg | High | +| Volume | The volume of the tri-band O-RU <sub>7-2x</sub> (n26+n29+n71) shall be less than 33 Liter. | High | +| | The volume of the dual-band O-RU <sub>7-2x</sub> (n66+n70) shall be less than 28 Liter. | High | +| | The volume of the single-band 64T64R O-RU <sub>7-2x</sub> (n77) shall be less than 81 Liters. | High | +| | The volume of the single-band 8T8R O-RU <sub>7-2x</sub> (n77) shall be less than 42.5 Liters. | High | +| | The volume of the single-band 32T32R O-RU <sub>7-2x</sub> (n78) shall be less than 45 Liters. | High | +| | The volume of the single-band 64T64R O-RU <sub>7-2x</sub> (n78) shall be less than 55 Liters. | | +| | The volume of the single-band 4T4R O-RU <sub>7-2x</sub> (B1/n1, B3/n3) shall be less than 16 Liters. | High | +| | The volume of the single-band 4T4R O-RU <sub>7-2x</sub> (B7/n7) shall be less than 18 Liters. | High | +| | The volume of the dual-band 4T4R O-RU <sub>7-2x</sub> (B1/n1+B3/n3 or B3/n3+B7/n7) shall be less than 24 Liters. | High | +| | The volume of the tri-band 4T4R O-RU <sub>7-2x</sub> (B1/n1+B3/n3+B7/n7) shall be less than 34 Liters. | High | +| | Maximum dimensions of tri-band O-RU <sub>7-2x</sub> (n26+n29+n71) and dual-band O-RU <sub>7-2x</sub> (n66+n70) should be 462mm (L) x 340mm (W) x 177 mm (D). Physical dimensions shall not exceed 890mm x 500mm x 250mm for 64T64R n77 radio. Physical dimensions shall not exceed 420mm x 420mm x 240mm for 8T8R n77 radio. For 64T64R n78 radio L < 800mm x W < 400mm x D < 250 mm. (including connectors and radome/sunshield). | High | +| Mounting Holes | A pattern of M8 mounting holes should be located on backside of the O-RU <sub>7-2x</sub> , with a total of 8 holes (4 towards top and 4 towards bottom). | High | +| Reliability | MTBF ≥ 250.000 hours for mMIMO<br><br>MTBF ≥ 300.000 hours for non mMIMO;<br><br>In normal operating conditions (ETSI 300 019 environment temperature +25°C). | High | +| Power Consumption | The tri-band O-RU <sub>7-2x</sub> (n26+n29+n71): shall be less than 1,200 Watt at 100% full loading, under all operational conditions. | High | +| | The dual-band O-RU <sub>7-2x</sub> (n66+n70): shall be less than 1,200W at 100% full loading, under all operational conditions. | High | +| | The single-band 64T64R O-RU <sub>7-2x</sub> (n77) shall be less than 1,810W at 100% full loading, under all operational conditions. Typical power measurement for 100% load may be done following 3GPP procedures for TDD with 7D1S2U configuration using TM1.1 with ~75% DL ratio in the slot. | High | +| | The single-band 32T32R O-RU <sub>7-2x</sub> (n78) shall be less than 800W at 100% full loading, under all operational conditions. Typical power measurement for 100% load may be done following 3GPP procedures for TDD with 7D1S2U configuration using TM1.1 with ~75% DL ratio in the slot. | High | + +| | | | +|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------| +| | The Wide band 64T64R O-RU <sub>7-2x</sub> (n78) shall be less than 1000W, assuming at 100% full loading, under all operational conditions and 55°C, 320W output power. Typical power measurement for 100% load may be done following 3GPP procedures for TDD with (DDDSU, with special subframe 10:2:2 slot format) configuration using TM1.1 with ~80% DL ratio in the slot. No fans. | High | +| | For O-RU <sub>7-2x</sub> Single band B1/n1 or Single band B3/n3 products shall be less than 500W, assuming at 100% full loading, under all operational conditions. At 55°C and for natural cooling (no fans). | High | +| | For O-RU <sub>7-2x</sub> Single band B7/n7 products shall be less than 700W, assuming at 100% full loading, under all operational conditions. At 55°C and for natural cooling (no fans). | High | +| | For O-RU <sub>7-2x</sub> Dual band B1/n1+B3/n3 or B3/n3+B7/n7 products shall be less than 950W, assuming at 100% full loading, under all operational conditions. At 55°C and for natural cooling (no fans). | High | +| | For O-RU <sub>7-2x</sub> Tri-band B1/n1+B3/n3+B7/n7 products shall be less than 1300W, assuming at 100% full loading, under all operational conditions. At 55°C and for natural cooling (no fans). | High | +| Power supply | The O-RU <sub>7-2x</sub> shall operate with the nominal voltage of -48V | High | +| | The O-RU <sub>7-2x</sub> shall have protection from power transients and surges with no impact/degradation to its performance or operation. | High | +| | In case of power loss to the O-RU <sub>7-2x</sub> , and after the power is restored, the O-RU <sub>7-2x</sub> shall be fully functional and operational without any human interaction/intervention. | High | +| Level of protection | O-RU <sub>7-2x</sub> shall be at a minimum IP65 rated if deployed outdoors | High | +| Temperature | O-RU <sub>7-2x</sub> shall operate at the temperature range of -40°C to +55°C with both cold start and hot start options. | High | +| Humidity | O-RU <sub>7-2x</sub> shall operate between 0.03 g/m <sup>3</sup> and 30 g/m <sup>3</sup> of absolute humidity | High | +| Atmospheric pressure | O-RU <sub>7-2x</sub> shall operate between 70 kPa and 106 kPa atmospheric pressure | High | +| Cooling mode | O-RU <sub>7-2x</sub> shall support convection air cooling | High | + +## 6.5 O-RU<sub>7-2x</sub> Split Option Specific Requirements + +Besides the common requirements which shall apply to all the radio unit types. The following sections list all the specific requirements that only apply to the designated split option. + +### 6.5.1 O-RU<sub>7-2x</sub> Specific Requirements + +‘This section intentionally left blank’. + +### 6.5.2 O-RU<sub>6</sub> Specific Requirements + +‘This section intentionally left blank’. + +### 6.5.3 O-RU<sub>8</sub> Specific Requirements + +‘This section intentionally left blank’. + +## 6.6 FHGW/FHM – Common Requirements + +‘This section intentionally left blank’. + +## 6.7 FHGW/FHM – Split Option Specific Requirements + +### 6.7.1 FHM/Switch for Split 7-2x, Specific Requirements + +‘This section intentionally left blank’. + +### 6.7.2 FHGW<sub>7-2x->8</sub> Specific Requirements + +‘This section intentionally left blank’. + +### 6.7.3 FHM/Switch for Split 8, Specific Requirements + +‘This section intentionally left blank’. + +## 6.8 Integrated gNB-DU Requirements + +‘This section intentionally left blank’. + +# History + +| Date | Revision | Description | +|------------|----------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.07.18 | 04.00 | Final version for publication<br>Update on O-RU requirements to reflect WG11 outcomes on security | +| 2022.07.19 | 03.00 | Final version for publication.<br>Added new section for Massive MIMO high level architecture and high-level reference architecture for Integrated gNB-DU Hardware Architecture (O-RU Functional Split 2) | +| 2021.07.16 | 02.00 | Final version for publication | +| 2020.10.21 | 01.00 | Final version for publication | \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/03fdcac559835d0d81bd64cf905084dd_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/03fdcac559835d0d81bd64cf905084dd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4b28169b553134a6f6b21e4f82ad71d6f2a54cad --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/03fdcac559835d0d81bd64cf905084dd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c97bea9072df51ebe8d006fc31a327fed29a887bddab41f41ccea16dc3a426a0 +size 4485 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/0d05f166f9e3fe350d30075e5d6cf3a6_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/0d05f166f9e3fe350d30075e5d6cf3a6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..adc53d779b7b7a6f317abcb1f2bb7f133243d227 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/0d05f166f9e3fe350d30075e5d6cf3a6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3178db85efc74b2377323088d28d2086ff9fb4cebbdb13df428c2489f82186fd +size 61227 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/0d7e47ca5eaf9d04fea5f4cab28b8d1e_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/0d7e47ca5eaf9d04fea5f4cab28b8d1e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1830e936c1307c65aaaf61952e67918e5f80f7b9 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/0d7e47ca5eaf9d04fea5f4cab28b8d1e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d678a109ab3d476577fb52525acbf30da3fbbd73e6c2252cd2505a79faffd1a0 +size 4485 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/0e9f68924ae66af5ddf97c4f7e9d6e46_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/0e9f68924ae66af5ddf97c4f7e9d6e46_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7008d8a78eaf5174d949c7699351a2e7f6e4ae3 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/0e9f68924ae66af5ddf97c4f7e9d6e46_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:10a77068221dc13e8b92cea4efeef3de21cbd2d30adc300fef79ffca74927275 +size 86873 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/1194775326b040853bc51892ee956684_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/1194775326b040853bc51892ee956684_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8f12326f4b707c275347ee45dfa85272f824f10d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/1194775326b040853bc51892ee956684_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9d8f8059f1461e3c1420aa08f8fe631c538126b2668825ca81140a6f46946fa3 +size 4487 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/13445caecbc7a80fbfa5be8606c13a97_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/13445caecbc7a80fbfa5be8606c13a97_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82ecad92e88b50c996b07c76d638d4f1fe42e294 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/13445caecbc7a80fbfa5be8606c13a97_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e8602de189460452c97692e61c219fd75ac8c3aee957ec883cd5467c37d63862 +size 64732 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/145bbb0f38ed95f46b5fb862dac1e97a_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/145bbb0f38ed95f46b5fb862dac1e97a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..133f21ab9a3e8a9accf6923858512515a2c72761 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/145bbb0f38ed95f46b5fb862dac1e97a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:77c3ef47744b1948d60601eae839ffe38685ecdf33ca5d866ac337b467d58ebd +size 92719 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/173aad7ccc334802be0f44ccc84c7ae3_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/173aad7ccc334802be0f44ccc84c7ae3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f3cf75cbefaad8fa17964251c2f2c43ad36d605 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/173aad7ccc334802be0f44ccc84c7ae3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:67a108405b5fac3458516a7197e74aaff99c247d67d511b955e95d4331648383 +size 4494 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/1bf5982d8291fa0f503910b7b52ada6e_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/1bf5982d8291fa0f503910b7b52ada6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f6ba3d60b7aa917ba99563134ebd73f2826d3469 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/1bf5982d8291fa0f503910b7b52ada6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cbe55d9dc922c8dacb5730fb97500a04723c5164ff7165a766519d140c5cf900 +size 58791 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/1ed472b32d40a9fa4ea1dd943a7c276b_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/1ed472b32d40a9fa4ea1dd943a7c276b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b27e683454104d0aaabc190578d800ea1a407c2e --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/1ed472b32d40a9fa4ea1dd943a7c276b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e0a12bf50dda27744b0185bfdf9e1d8f7097ba00de0614da5b56fb263476782b +size 5268 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/29e01a7845f4656d99a2bb50629b7e8f_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/29e01a7845f4656d99a2bb50629b7e8f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6ad137cdb6c368efaf6ce0aae87a19a5264db01c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/29e01a7845f4656d99a2bb50629b7e8f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3b7ef25c2b8a15016cf9b5cc8559d3513da5c4df584ed9477ec913f94289ada7 +size 52404 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/2d143272f6b2c1c94ba672d536283a66_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/2d143272f6b2c1c94ba672d536283a66_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..624f73992e9dfd5989b3a6bf6e6ade0e64ccf80c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/2d143272f6b2c1c94ba672d536283a66_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ea2d5172f1ea4f9022d33b12918bfdadbe53eeb4dfcfc78392f340497615d703 +size 108051 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/2fc219629c9abf3dcdd8eed9f3e62061_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/2fc219629c9abf3dcdd8eed9f3e62061_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..82a1c997ff8b9fd576f1ae534a0b89c768073493 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/2fc219629c9abf3dcdd8eed9f3e62061_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:18aa118cce7e8cb929e838405fc7f088c094247288581b4b46651b030e6d1c31 +size 84410 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/397b9da046463e68f3ce2d32778395f8_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/397b9da046463e68f3ce2d32778395f8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..26e56c374a7c4b9b1383054e2840e16a9a6cda33 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/397b9da046463e68f3ce2d32778395f8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f04d772387765bd66332934dbc20e8976fa352daca1f987f70110c9def09eba5 +size 60754 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/3b74b918f90cb274b2c4229c01d6794f_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/3b74b918f90cb274b2c4229c01d6794f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5f01ed72631c930e7f4f30bae5c781514574289a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/3b74b918f90cb274b2c4229c01d6794f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9c1cc9267b9c6a62681f42edf211302516739a37e8becb109d35e4bf7612d602 +size 22863 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/3bdd45143e340a430ea6d08c3e5b0ede_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/3bdd45143e340a430ea6d08c3e5b0ede_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cee34986593be77f6a72a80c02fb5f54bdd52a67 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/3bdd45143e340a430ea6d08c3e5b0ede_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:05bab37a6cce08d601dbbce1b86bd35d2b39552c1b748131e0c2960e1e183766 +size 4543 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/430fb53cd7129084e74b2ef64c81da95_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/430fb53cd7129084e74b2ef64c81da95_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8e2552f360d8b37f2468eefdb95736ebc7f140ff --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/430fb53cd7129084e74b2ef64c81da95_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d1e18ddb5909d31db17d0f23b01be7b30e7f65b49844b4b641e062cc8e72964 +size 4432 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/477afbf9aff73ff7414cea96a6f7633f_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/477afbf9aff73ff7414cea96a6f7633f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3e48e449f9d3b29ad94a703d48e4bd393e678c74 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/477afbf9aff73ff7414cea96a6f7633f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7ac106bb156b0dfb12c9b88daa9443fe880a2153709c3fa36f77d8f0eb725b2 +size 98074 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4aebbe7212644be7d742c6c05f6e4db4_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4aebbe7212644be7d742c6c05f6e4db4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dfdfe273985d4e463f16489f8af84b5d7be6836d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4aebbe7212644be7d742c6c05f6e4db4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f8d10037e41a9f264acb753cc5ee73abdab40d95bc77824d6b554d28cf76702f +size 35337 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4b8007951ef875078d49e88b7890efbc_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4b8007951ef875078d49e88b7890efbc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..643bd56add3f1944e1cdee9608309f4e622f73f1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4b8007951ef875078d49e88b7890efbc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2d27b2ae16f3172ab13e38f55a892c49875586b046c0cf336824c8d7cc1b650e +size 4565 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4dce309123f1bcc76d97a45ba081853d_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4dce309123f1bcc76d97a45ba081853d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aff298ff2dfe71962dd3bfb3fadff4483f3b0605 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4dce309123f1bcc76d97a45ba081853d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:40aa506c24bc0976e289cb2c6776b4b4e0a153b1871f4ac901e9a5e8fe015170 +size 182113 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4e709eaacfffa9cdb2e5b94fb173a796_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4e709eaacfffa9cdb2e5b94fb173a796_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dec0cbca3758a74ba6f062cc801de0d076c0e758 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4e709eaacfffa9cdb2e5b94fb173a796_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:18b53667ab2648cbc4a81777ce4404c95e2dcba76f06b9983a9e9cd837a2935d +size 82025 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4f03056698625890adbfc7ec6caa0808_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4f03056698625890adbfc7ec6caa0808_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..83b3f35faaeb145cef29d1c2ff332c475b7c55bc --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/4f03056698625890adbfc7ec6caa0808_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:10e3fcb455695619bc373876d8c31c3ad18b5043789cede3fd6bf78f2ef7c4f5 +size 18512 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/5168df759a16335758efba98247ff102_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/5168df759a16335758efba98247ff102_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bc8c5abfa00c5366aa61dfae8a88eeae6b30a862 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/5168df759a16335758efba98247ff102_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:55203adea8687a167d0d0cfcd363792961dba99bb2b07a1fb9cd9d16a989cabc +size 147996 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/56956e261504ecd291a7758cf7a5482b_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/56956e261504ecd291a7758cf7a5482b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2744b894bbc15b039f6989cb7d33f018d5a1aa70 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/56956e261504ecd291a7758cf7a5482b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d45fe6ed5332004acdff89660efb3bb82647c06b2a467f72ec01e0131820da47 +size 49303 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/58c0f87982f518b51c65048b682e7b36_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/58c0f87982f518b51c65048b682e7b36_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..086f547d3c3db62bd7eef519ff83bd8126adbd85 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/58c0f87982f518b51c65048b682e7b36_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab7687a0612fe8bec69181449c9943cc89258465324d9a8c2a0c4fe6ba3d918b +size 35472 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/602137eca0727354016f142d754cb265_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/602137eca0727354016f142d754cb265_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..efb90390b60d4689f933bb69e26751f2087f6dde --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/602137eca0727354016f142d754cb265_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:993a7c43dc562d530ef6c3c42e3ddbb63829439fb49e7e9876ce3ea140c98886 +size 143127 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/604aa18f8cfa97dff3b5f56fd72c4079_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/604aa18f8cfa97dff3b5f56fd72c4079_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..95da9635f4535a2e5846c764eed996a1decf444a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/604aa18f8cfa97dff3b5f56fd72c4079_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:368d3837e8f0e0e63e3d1f2c9de68adbe8d443f97dd34af49f7a957fdbd5d675 +size 88272 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/66b2e719a086d0042afe551bafd1084b_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/66b2e719a086d0042afe551bafd1084b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d601e38112473ad4d80eb133c9eda270a9b9d955 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/66b2e719a086d0042afe551bafd1084b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:25b6c89149c8e8d28572dd7336d5fd6a1e38f5945c5ba37fb16dd674dd767183 +size 15590 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/6c05557f1d72e467b7418e58a05b7993_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/6c05557f1d72e467b7418e58a05b7993_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dc5c6bbb3bd48a3e9051cccf8b4c13013a4a09f9 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/6c05557f1d72e467b7418e58a05b7993_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fe675be69e6f6a30565836254e53b8b9265084d35acb498fb9afaf04c7c86e67 +size 45896 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/6f925fc59ee100548f0a4b96ebf5e248_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/6f925fc59ee100548f0a4b96ebf5e248_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..21e6dc589105d91aa2a04a6eacc1c284568971d7 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/6f925fc59ee100548f0a4b96ebf5e248_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7e6a96dbb8f90b16710a88f07e43035ad1c0092d5ddc6749ee6c29a9c9128601 +size 58418 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/72c85686d34c8c65b37b51b9a38f5c69_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/72c85686d34c8c65b37b51b9a38f5c69_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4f23b5b915ab4d7a3b54382e3ea7d3415cff14d4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/72c85686d34c8c65b37b51b9a38f5c69_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:27747f7645fb0163d426a7ba9fb5ddc11f4551d0cfd80bea7454574cb721656a +size 16949 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7590c0aad657ef8cb87abf73d219002a_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7590c0aad657ef8cb87abf73d219002a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e88df28bb5d9a0600ae00946f94b6593ae357983 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7590c0aad657ef8cb87abf73d219002a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:14565c614cb4e4d7ac491981b561778947e24788c48c1392ec460c33c45613b3 +size 23868 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7855a94891d81f91bbb196295c2dcf03_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7855a94891d81f91bbb196295c2dcf03_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..90455cd0819d20e7b9c3f3e80dccf705b8afc1dc --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7855a94891d81f91bbb196295c2dcf03_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f0677cd2f9d0d8281c7452599d9333d16dd4b6f0622836ebc9ecdd09172b73b8 +size 4467 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/786e969bdcec853366e7f08b63f6e656_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/786e969bdcec853366e7f08b63f6e656_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..44033d70254a329d00998db2cb5bce42c190b6db --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/786e969bdcec853366e7f08b63f6e656_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:16b50a6bcab6c579df6f6c3fba6bd8b25e44fbbb3a11bc00bf652440c987d0c8 +size 43511 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7c8d96ce1db2a4c1c52df5f19f50cd68_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7c8d96ce1db2a4c1c52df5f19f50cd68_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5bfdf9c46f56623b9f0b7fa12ed19689c17f949a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7c8d96ce1db2a4c1c52df5f19f50cd68_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:892ba8bf822896490871400204aafdaab87b87d49b7b097a44e1e3242aef1788 +size 53867 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7fff3e33a4bb036da4ac7edb2c6ebf98_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7fff3e33a4bb036da4ac7edb2c6ebf98_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6bf008904044ac13230bea2f269c198db1beeefb --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/7fff3e33a4bb036da4ac7edb2c6ebf98_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a014d924803f9ef4dc335f36b695362e1ece0a034cb1daa6803cf234d2e50b30 +size 43945 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/843aa608ace1aa3ffea79052d31676b4_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/843aa608ace1aa3ffea79052d31676b4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a63934e0bba267d70407cccb253cae4dc053cb6e --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/843aa608ace1aa3ffea79052d31676b4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9a7688e4c0c1fa60fd2a013e61b6348de34ef08d9210b3c3ab25b07b0bfc9399 +size 4533 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/9c5249266b967bea1a41c9fa9fe97f96_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/9c5249266b967bea1a41c9fa9fe97f96_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7a0e841f673fd6eb51c5e839088e643bb7582616 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/9c5249266b967bea1a41c9fa9fe97f96_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:58b062c9c68bc9693973649796ed85dc557eb257c2d7251b3ba161879c7256b4 +size 18075 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/9e184c620ad8cd561b475de0ca1d42df_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/9e184c620ad8cd561b475de0ca1d42df_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e0ef5bca77857c18532ced742a114ea1108f952d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/9e184c620ad8cd561b475de0ca1d42df_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:edf81d465dad2130f8071cd21fe4a30741152cc49515684b67672202ee7ea919 +size 84656 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b139ce0bd8dcfdf5f29bb4b507489384_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b139ce0bd8dcfdf5f29bb4b507489384_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..146ec576c60d0cfc6dc6da5b6265ec832795c4c6 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b139ce0bd8dcfdf5f29bb4b507489384_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:58e243e7d100e933c7fa25d1ed9cbab2e693c3cc21b593b47184247c4feced6b +size 43375 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b2908336394c9c44a79686a38b854aec_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b2908336394c9c44a79686a38b854aec_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9c989e159733edc3b877d886c8c88771ce38f1c5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b2908336394c9c44a79686a38b854aec_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:71ff647b0be3782f18d67b4eb249b4531bbca949365784d24f58846090fcf0f4 +size 18409 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b2d0a4336d004005ec3188194666be40_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b2d0a4336d004005ec3188194666be40_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6c2c06a36232c3596bc29300e48a697a42b61512 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b2d0a4336d004005ec3188194666be40_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:83b5f0bf72a027cdd3abad7fe4c981ac24470ab910203c932951bca710856ee2 +size 75701 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b47d300e917e0fbc5c7fe8eb641c4011_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b47d300e917e0fbc5c7fe8eb641c4011_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dcfea580b1a830b67c5843d0b4957a8074f43053 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b47d300e917e0fbc5c7fe8eb641c4011_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b904b2525675b2e1d54c0c6ccfb5b7f1f8fe11aae6b00e5dfc81597d71e4eff5 +size 15412 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b5e2ec01242503d08905c82bb0b4dda1_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b5e2ec01242503d08905c82bb0b4dda1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9724854251540c5e8baf7b92596c7c233c536e46 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b5e2ec01242503d08905c82bb0b4dda1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:870fae527862339ff28c3b5bae23b5c1d205fc5c3195cb1a2c1de4971e507f59 +size 74355 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b7f36e332fb78c1d62f91399015a492c_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b7f36e332fb78c1d62f91399015a492c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5923d10abd8abf851f16c4e4b53034a29822375c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b7f36e332fb78c1d62f91399015a492c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1ff9cdbb212e4fc064f49d9de0931d54fc23351aae7e09b0d89524c406f0c9d0 +size 68508 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b842eb51a146fd3de7f69a858c97d041_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b842eb51a146fd3de7f69a858c97d041_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c1299c64d95ab479fe5a4c6364ab168f4d62c759 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/b842eb51a146fd3de7f69a858c97d041_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09f75b547ccc5e3ac914a7a2610824871903d2a6800e7f652b58675809fc02c6 +size 167636 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/ba05974dc72c1dc10cfd85718647f615_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/ba05974dc72c1dc10cfd85718647f615_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..053ec2c5c706fc8ffac353cba5a8207637e6b1fb --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/ba05974dc72c1dc10cfd85718647f615_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e1ddb633ca15496b91bcbc9ee4da2360ebc3574fbc230c35f7a70c6659081bfd +size 4456 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/bae62e77927998f9999c32dde93f767f_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/bae62e77927998f9999c32dde93f767f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..739d5370e01d63d258556aacf5642cc83b11eefa --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/bae62e77927998f9999c32dde93f767f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a6902d04c4467ef79ecd29ae478cfa7e704969221ca45807c4ec23615f393450 +size 60878 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/bb2c61be3025d1ddb64910b1527a2a1e_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/bb2c61be3025d1ddb64910b1527a2a1e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3083340927641da82ac9f06a31025f71a2c0b91 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/bb2c61be3025d1ddb64910b1527a2a1e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3392c9d3bb428a5244ddec89b9cf3070d8edf7b1042a507b3b16978d5db9b281 +size 75603 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/bc79d6fd9a39064fa6165e38ff9aacb3_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/bc79d6fd9a39064fa6165e38ff9aacb3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d2a538fe7f3c0e386dc0a09f3ed1897771aa477a --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/bc79d6fd9a39064fa6165e38ff9aacb3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b52e36b77fbe141b88bb545b1c47ed554fdbaf2f7743a49b64c433765818225c +size 47704 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/be03a196af194c2e616f80f5ddb1f198_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/be03a196af194c2e616f80f5ddb1f198_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..808d3347262d21ca65b2028a12aeae6c4a44b2d3 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/be03a196af194c2e616f80f5ddb1f198_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cc8ea2f49f190ca709e458a94152dcee2c661e5807d56fbe8f0dd98ea25ea51f +size 4456 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/c6c413f541ba441a93cf8db8146d8861_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/c6c413f541ba441a93cf8db8146d8861_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..21de96a8317bfb88060ac64ab053b6611206d909 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/c6c413f541ba441a93cf8db8146d8861_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5120d748566c18170a95e2c21431d64a016bd192a666120ffe67540fbb804c2d +size 6426 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/c77708aa0c4825171d5d6f726bfcad8a_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/c77708aa0c4825171d5d6f726bfcad8a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..721cefb10a54e0ea6b67e0d457167f7cfe697fbe --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/c77708aa0c4825171d5d6f726bfcad8a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a1295e78cd3af3f80a93630568ea6d26ca0a0510ecca762ce18b706358bb4cf1 +size 4517 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/cacc286c1830213a695461a009418677_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/cacc286c1830213a695461a009418677_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1bfcc4f1209846eb717c73b1c726249fc09409a4 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/cacc286c1830213a695461a009418677_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6edf2a0b3163110ba9c994e06eff67478c1901be2331af673085a8eb5d2ffb8c +size 4522 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/cc1b1b9ed0e7d7dfb0655fe914214205_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/cc1b1b9ed0e7d7dfb0655fe914214205_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..76e0a6ae98825e64601ff3fd1f84131d78842680 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/cc1b1b9ed0e7d7dfb0655fe914214205_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c5878fd8d98bc38994163b10389901e318a57f406d165ab9603a39845ce288f3 +size 42362 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/d1bd7a6d95b0f29930b2c64d2bc5e54e_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/d1bd7a6d95b0f29930b2c64d2bc5e54e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bc0ee336eb56cda1301196b285d5861950e93763 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/d1bd7a6d95b0f29930b2c64d2bc5e54e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:18b80d93192440c11d862a0e33d56674d45f03d1da9f1a6f72d2b33a686201b8 +size 59822 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/d61054715824de90884b91b8c2380e94_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/d61054715824de90884b91b8c2380e94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..268edfd793f642dd6f1b5e5ee834cb31a8b401a8 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/d61054715824de90884b91b8c2380e94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6baacd0c234cf537056c5bff7a3e68ec499dfcefd6729230e931f08dacf45697 +size 25055 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/e065d418f12edd03b227136babcfe39f_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/e065d418f12edd03b227136babcfe39f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..181f9c89327838ac5dcf50ff0284f6354a916be3 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/e065d418f12edd03b227136babcfe39f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:396c869b9f3ab032a2c7660fe93c572035fa9d1c20f8729eef7d44a2f44e09b2 +size 17881 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/edd8a810bc5367f11a90919ed8584a0c_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/edd8a810bc5367f11a90919ed8584a0c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db72cf02dc2e82a1490c8d53ff8df67d855eea98 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/edd8a810bc5367f11a90919ed8584a0c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d85e2169807317b4e993ea95d21c2609de7a4e7bbf75268ac57dfae1520849c0 +size 67033 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/f4813e05d2939e6f5e15761d527fad32_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/f4813e05d2939e6f5e15761d527fad32_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..45908eaedb2db1c2d04f6d5c8f0ee71a90e90956 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/f4813e05d2939e6f5e15761d527fad32_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a1ac23187295c456f5688f965676645d7c5d6bcb808afc4a586e415c87395a4 +size 4541 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/f55f0b7209d3d339e6ab712e92ac917e_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/f55f0b7209d3d339e6ab712e92ac917e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4c1498c220580c74e69c4a93da20084a4f6c2eff --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/f55f0b7209d3d339e6ab712e92ac917e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:92efed9e7ced67612cd5bed5d78882db04262425a949b9fe8b1109c653c935b0 +size 31314 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/f6db8899a4ac51e9f125bcff1d10a035_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/f6db8899a4ac51e9f125bcff1d10a035_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de515ec5a5c8828c0a46a1c2dff991d140790307 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/f6db8899a4ac51e9f125bcff1d10a035_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d3d323789c00725a8fb361c13dc09b3a81beef0cf91f29594e1f4f828e22e96f +size 91100 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/fa04ba5c7b3bdf566569c96c21bb1c6e_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/fa04ba5c7b3bdf566569c96c21bb1c6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9a1d05b275a7a108995b2925413d3d11e7df351d --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/fa04ba5c7b3bdf566569c96c21bb1c6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:908b606a2e5886f7d53f79e6b0b769b707d3d8a7d534ff174ea1d2d121fde294 +size 68332 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/fc2e3c4028983eac7d8cea231280ce9e_img.jpg b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/fc2e3c4028983eac7d8cea231280ce9e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..409f97834f9af15c96fee9129305d39905ec8da5 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/fc2e3c4028983eac7d8cea231280ce9e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e81b5b3d95f3596ef2798f1abde3afac4139d875d6fa1e4c135ad019f4b06a3b +size 15327 diff --git a/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/raw.md b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..99d219195df45e1c978603b09a1340c05c834396 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00/raw.md @@ -0,0 +1,2445 @@ + + +# --- **O-RAN Working Group 7 Whitebox Hardware Hardware Reference Design Specification for Outdoor Macrocell with Split Architecture Option 7.2** + +Copyright © 2023 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +# Contents + +| | | | +|----|------------------------------------------------------------|----| +| 1 | Figures ..... | 5 | +| 2 | Tables ..... | 7 | +| 3 | Foreword ..... | 9 | +| 4 | Modal verbs terminology ..... | 9 | +| 5 | Chapter 1 Introductory Material ..... | 10 | +| 6 | 1.1 Scope ..... | 10 | +| 7 | 1.2 References ..... | 10 | +| 8 | 1.3 Definitions and Abbreviations ..... | 11 | +| 9 | 1.3.1 Definitions..... | 11 | +| 10 | 1.3.2 Abbreviations ..... | 12 | +| 11 | Chapter 2 Hardware Reference Design 1 ..... | 17 | +| 12 | 2.1 O-CU Hardware Reference Design ..... | 17 | +| 13 | 2.1.1 O-CU High-Level Functional Block Diagram ..... | 17 | +| 14 | 2.1.2 O-CU Hardware Components ..... | 18 | +| 15 | 2.1.2.1 Digital Processing Unit..... | 18 | +| 16 | 2.1.2.2 Hardware Accelerator (If required by design)..... | 18 | +| 17 | 2.1.2.2.1 Accelerator Design 1 ..... | 18 | +| 18 | 2.1.2.2.2 Accelerator Design 2 ..... | 18 | +| 19 | 2.1.3 Synchronization and Timing ..... | 18 | +| 20 | 2.1.4 External Interface Ports ..... | 18 | +| 21 | 2.1.5 O-CU Firmware (if needed) ..... | 18 | +| 22 | 2.1.6 Mechanical ..... | 18 | +| 23 | 2.1.7 Power Unit ..... | 18 | +| 24 | 2.1.8 Thermal ..... | 18 | +| 25 | 2.1.9 Environmental and Regulations ..... | 18 | +| 26 | 2.2 O-DU Hardware Reference Design..... | 18 | +| 27 | 2.2.1 O-DU High-Level Functional Block Diagram ..... | 19 | +| 28 | 2.2.2 O-DU Hardware Components ..... | 20 | +| 29 | 2.2.2.1 Digital Processing Unit..... | 20 | +| 30 | 2.2.2.1.1 Interfaces..... | 20 | +| 31 | 2.2.2.1.1.1 Memory Channel Interfaces ..... | 20 | +| 32 | 2.2.2.1.1.2 PCIe..... | 20 | +| 33 | 2.2.2.1.1.3 Ethernet ..... | 21 | +| 34 | 2.2.2.2 Hardware Accelerator (if required by design) ..... | 21 | +| 35 | 2.2.2.2.1 Hardware Accelerator ..... | 21 | +| 36 | 2.2.2.2.2 Accelerator Design 1 ..... | 21 | +| 37 | 2.2.2.2.3 Accelerator Design 2 ..... | 23 | +| 38 | 2.2.2.2.4 Accelerator Design 3 ..... | 24 | +| 39 | 2.2.3 Synchronization and Timing ..... | 27 | +| 40 | 2.2.4 External Interface Ports ..... | 27 | +| 41 | 2.2.5 O-DU Firmware ..... | 28 | +| 42 | | | + +| | | | | +|----|---------------|--------------------------------------------------|----| +| 1 | 2.2.6 | Mechanical ..... | 28 | +| 2 | 2.2.6.1 | Mother Board ..... | 28 | +| 3 | 2.2.6.2 | Chassis..... | 30 | +| 4 | 2.2.6.3 | Cooling..... | 30 | +| 5 | 2.2.7 | Power Unit ..... | 30 | +| 6 | 2.2.7.1 | Power Supply ..... | 30 | +| 7 | 2.2.8 | Thermal ..... | 31 | +| 8 | 2.2.9 | Environmental and Regulations ..... | 31 | +| 9 | 2.3 | O- RU Hardware Reference Design ..... | 31 | +| 10 | 2.3.1 | O- RU High-Level Functional Block Diagram ..... | 32 | +| 11 | 2.3.2 | O-RU Hardware Components ..... | 32 | +| 12 | 2.3.2.1 | O-RAN Processing Unit..... | 36 | +| 13 | 2.3.2.2 | Digital Processing Unit..... | 36 | +| 14 | 2.3.2.2.1 | FPGA/ASIC Solution ..... | 37 | +| 15 | 2.3.2.2.1.1 | FPGA Requirements ..... | 37 | +| 16 | 2.3.2.2.1.2 | FPGA Design ..... | 37 | +| 17 | 2.3.2.3 | RF Processing Unit..... | 38 | +| 18 | 2.3.2.3.1 | Transceiver Reference Design ..... | 38 | +| 19 | 2.3.2.3.1.1 | Hardware Specifications ..... | 38 | +| 20 | 2.3.2.3.1.1.1 | Interface..... | 38 | +| 21 | 2.3.2.3.1.1.2 | Algorithm ..... | 39 | +| 22 | 2.3.2.3.1.1.3 | Device Configuration ..... | 40 | +| 23 | 2.3.2.3.1.1.4 | Power Dissipation..... | 40 | +| 24 | 2.3.2.3.1.1.5 | RF Specifications..... | 40 | +| 25 | 2.3.2.3.1.2 | Hardware Design..... | 42 | +| 26 | 2.3.2.4 | Interface Requirements..... | 43 | +| 27 | 2.3.2.4.1 | O-RAN Processing Unit and DPU Design ..... | 44 | +| 28 | 2.3.2.4.2 | Power Amplifier (PA) Reference Design ..... | 45 | +| 29 | 2.3.2.4.2.1 | Hardware Specifications ..... | 45 | +| 30 | 2.3.2.4.2.1.1 | Interface..... | 45 | +| 31 | 2.3.2.4.2.1.2 | Power Specifications ..... | 45 | +| 32 | 2.3.2.4.2.1.3 | RF Specifications..... | 45 | +| 33 | 2.3.2.4.2.2 | Hardware Design..... | 46 | +| 34 | 2.3.2.4.3 | Low Noise Amplifier (LNA) Reference Design ..... | 46 | +| 35 | 2.3.2.4.3.1.1 | Interface..... | 46 | +| 36 | 2.3.2.4.3.1.2 | Power Specifications ..... | 47 | +| 37 | 2.3.2.4.3.1.3 | RF Performance Specifications ..... | 47 | +| 38 | 2.3.2.4.3.2 | Hardware Design..... | 47 | +| 39 | 2.3.2.4.4 | Circulator Reference Design..... | 47 | +| 40 | 2.3.2.4.4.1 | Hardware Specifications ..... | 48 | +| 41 | 2.3.2.4.4.1.1 | Interface..... | 48 | +| 42 | 2.3.2.4.4.1.2 | RF Specifications..... | 48 | +| 43 | 2.3.2.4.4.2 | Hardware Design..... | 48 | +| 44 | 2.3.2.4.5 | Antenna / Phased Array Reference Design ..... | 48 | + +| | | | | +|----|---------------|-----------------------------------------------------------|----| +| 1 | 2.3.2.4.5.1 | Hardware Specifications for Omnidirectional Antenna ..... | 49 | +| 2 | 2.3.2.4.5.2 | Hardware Design of Omnidirectional Antenna ..... | 49 | +| 3 | 2.3.2.4.5.3 | Hardware Specifications for Directional Antenna..... | 50 | +| 4 | 2.3.2.4.5.4 | Hardware Design of Directional Antenna ..... | 50 | +| 5 | 2.3.2.5 | Internal Interfaces ..... | 51 | +| 6 | 2.3.2.5.1 | Optional JESD204 Interfacing..... | 51 | +| 7 | 2.3.3 | Synchronization and Timing ..... | 58 | +| 8 | 2.3.3.1 | Hardware Specifications..... | 58 | +| 9 | 2.3.3.1.1 | Interface ..... | 58 | +| 10 | 2.3.3.1.2 | Performance Specifications ..... | 58 | +| 11 | 2.3.3.1.3 | Synchronizer ..... | 59 | +| 12 | 2.3.3.1.3.1 | Hardware Specifications ..... | 59 | +| 13 | 2.3.3.1.3.1.1 | Interface..... | 59 | +| 14 | 2.3.3.1.3.1.2 | Performance Specifications ..... | 59 | +| 15 | 2.3.3.1.3.2 | Hardware Design..... | 60 | +| 16 | 2.3.3.1.4 | Reference Synthesizer..... | 60 | +| 17 | 2.3.3.1.4.1 | Hardware Specifications ..... | 60 | +| 18 | 2.3.3.1.4.1.1 | Interface..... | 60 | +| 19 | 2.3.3.1.4.1.2 | Performance Specifications ..... | 61 | +| 20 | 2.3.3.1.4.2 | Hardware Design..... | 62 | +| 21 | 2.3.4 | External Interface Ports..... | 63 | +| 22 | 2.3.4.1 | Hardware Specifications..... | 63 | +| 23 | 2.3.4.2 | Hardware Design for External Interfaces ..... | 63 | +| 24 | 2.3.4.2.1 | Fronthaul Interface..... | 63 | +| 25 | 2.3.4.2.2 | Debug Interface..... | 63 | +| 26 | 2.3.4.2.3 | Power Interface ..... | 64 | +| 27 | 2.3.4.2.4 | RF Interface ..... | 64 | +| 28 | 2.3.5 | Mechanical ..... | 65 | +| 29 | 2.3.6 | Power Unit ..... | 66 | +| 30 | 2.3.6.1 | Hardware Specifications..... | 66 | +| 31 | 2.3.6.2 | Hardware Design ..... | 67 | +| 32 | 2.3.7 | Thermal ..... | 68 | +| 33 | 2.3.8 | Environmental and Regulations ..... | 69 | +| 34 | 2.4 | Integrated O-DU & O-RU (gNB-DU) Reference Design..... | 70 | +| 35 | 2.4.1 | O-DU Portion of Integrated Reference Design ..... | 70 | +| 36 | 2.4.1.1 | O-DU High-Level Functional Block Diagram ..... | 70 | +| 37 | 2.4.1.2 | O-DU Hardware Components ..... | 71 | +| 38 | 2.4.1.2.1 | Digital Processing Unit..... | 72 | +| 39 | 2.4.1.2.2 | Hardware Accelerator (if required by design) ..... | 72 | +| 40 | 2.4.1.2.2.1 | Accelerator Design 1 ..... | 72 | +| 41 | 2.4.1.2.2.2 | Accelerator Design 2 ..... | 72 | +| 42 | 2.4.1.3 | Synchronization and Timing ..... | 72 | +| 43 | 2.4.2 | O-RU Portion of Integrated Reference Design ..... | 72 | +| 44 | 2.4.2.1 | O-RU High-Level Functional Block Diagram..... | 72 | +| 45 | 2.4.2.2 | O-RU Hardware Components ..... | 73 | + +| | | | | +|----|------------------------------------|--------------------------------------------------------------------------------|----| +| 1 | 2.4.2.2.1 | Digital Processing Unit..... | 73 | +| 2 | 2.4.2.2.2 | RF Processing Unit ..... | 73 | +| 3 | 2.4.2.2.2.1 | Transceiver Reference Design..... | 73 | +| 4 | 2.4.2.2.2.2 | Power Amplifier (PA) Reference Design..... | 73 | +| 5 | 2.4.2.2.2.3 | Low Noise Amplifier (LNA) Reference Design ..... | 73 | +| 6 | 2.4.2.2.2.4 | RF Switch Reference Design ..... | 73 | +| 7 | 2.4.2.2.2.5 | Antenna / Phased Array Reference Design ..... | 73 | +| 8 | 2.4.2.2.3 | Synchronization and Timing..... | 74 | +| 9 | 2.4.3 | External Interface Ports..... | 74 | +| 10 | 2.4.4 | O-DU/O-RU Firmware (if required by design)..... | 74 | +| 11 | 2.4.5 | Mechanical..... | 74 | +| 12 | 2.4.6 | Power Unit ..... | 74 | +| 13 | 2.4.7 | Thermal ..... | 74 | +| 14 | 2.4.8 | Environmental and Regulations ..... | 74 | +| 15 | 2.5 | O- RU <sub>7-2x</sub> Massive MIMO Hardware Reference Design..... | 75 | +| 16 | 2.5.1 | O-RU <sub>7-2x</sub> Massive MIMO High-Level Functional Block Diagram ..... | 75 | +| 17 | 2.5.1.1 | O-RU <sub>7-2x</sub> Massive MIMO High Level Architecture Option #1 ..... | 76 | +| 18 | 2.5.1.2 | O-RU <sub>7-2x</sub> Massive MIMO High Level Architecture Option #2 ..... | 76 | +| 19 | 2.5.1.3 | O-RU <sub>7-2x</sub> Massive MIMO High Level Architecture Option #3 ..... | 77 | +| 20 | 2.5.2 | O-RU <sub>7-2x</sub> Massive MIMO Hardware Reference Design Architecture ..... | 77 | +| 21 | 2.5.2.1 | O-RAN Fronthaul Processing Unit..... | 79 | +| 22 | 2.5.2.2 | Digital Processing Unit..... | 79 | +| 23 | 2.5.2.3 | RF Processing Unit..... | 80 | +| 24 | 2.5.2.3.1 | RF Transceiver Unit..... | 80 | +| 25 | 2.5.2.3.2 | RF Front End Unit ..... | 80 | +| 26 | 2.5.2.4 | mMIMO Antenna/Phased array reference design ..... | 82 | +| 27 | 2.5.3 | Mechanical ..... | 86 | +| 28 | 2.6 | FHGW Hardware Reference Design ..... | 88 | +| 29 | Annex 1: Parts Reference List..... | | 89 | +| 30 | 1.1 Supermicro O-DU: ..... | | 89 | +| 31 | 1.2 ADI Based O-RU 4T4R: ..... | | 89 | +| 32 | 1.3 ADI Based O-RU 8T8R: ..... | | 90 | +| 33 | History ..... | | 90 | +| 34 | | | | + +# Figures + +| | | | +|----|--------------------------------------------------------------------------|----| +| 36 | Figure 2.2.1-1 O-DU/O-CU Functional Block Diagram ..... | 19 | +| 37 | Figure 2.2.2-1 Dual-chip FPGA-based Hardware Acceleration in O-DU ..... | 23 | +| 38 | Figure 2.2.2-2 Single-chip FPGA-based Hardware Acceleration in O-DU..... | 24 | +| 39 | Figure 2.2.2-3 Accelerator Design 3 using PCIe ..... | 26 | +| 40 | Figure 2.2.2-4 Accelerator Design 3 using Ethernet..... | 26 | + +| | | | +|----|--------------------------------------------------------------------------------------------------------------------------|----| +| 1 | Figure 2.2.6-1 Mother Board Layout Diagram ..... | 29 | +| 2 | Figure 2.2.6-2 Chassis Mechanical Diagram ..... | 30 | +| 3 | Figure 2.3.1-1 O-RU High-Level Functional Block Diagram ..... | 32 | +| 4 | Figure 2.3.2-1 O-RU Architecture Example Implementation 1 ..... | 33 | +| 5 | Figure 2.3.2-2 4T4R General Block Diagram with full RF front end ..... | 34 | +| 6 | Figure 2.3.2-3 8T8R General Block Diagram with RF front end ..... | 35 | +| 7 | Figure 2.3.2-4 Digital Processing Unit Block Diagram (L1 Processing + Beamforming) ..... | 36 | +| 8 | Figure 2.3.2-5 Digital Processing Unit Block Diagram (DFE) ..... | 36 | +| 9 | Figure 2.3.2-6 Transceiver with Integrated CFR and DPD ..... | 43 | +| 10 | Figure 2.3.2-7 Power Amplifier Reference Design ..... | 46 | +| 11 | Figure 2.3.2-8 LNA Reference Design ..... | 47 | +| 12 | Figure 2.3.2-9 Circulator Reference Design ..... | 48 | +| 13 | Figure 2.3.2-10 Canister Style Omni Antenna ..... | 49 | +| 14 | Figure 2.3.2-11 Mounting Arrangement Scenario 1 of 4T4R Radios back of the Directional Antenna ..... | 50 | +| 15 | Figure 2.3.2-12 Mounting Arrangement Scenario 2 of 4T4R Radios back of the Directional Antenna ..... | 51 | +| 16 | Figure 2.3.2-13 Example 4T4R JESD204 Configuration ..... | 54 | +| 17 | Figure 2.3.2-14 Example 64T64R JESD204 Configuration ..... | 56 | +| 18 | Figure 2.3.2-15 64T64R Example Data Mapping ..... | 57 | +| 19 | Figure 2.3.3-1 Clock and Synchronization Functional Block Diagram ..... | 58 | +| 20 | Figure 2.3.3-2 Synchronizer Block Diagram ..... | 60 | +| 21 | Figure 2.3.3-3 Synthesizer Block Diagram ..... | 62 | +| 22 | Figure 2.3.4-1 SFP+ case and connector ..... | 63 | +| 23 | Figure 2.3.4-2 RJ45 Interface ..... | 64 | +| 24 | Figure 2.3.4-3 Power Interface ..... | 64 | +| 25 | Figure 2.3.4-4 (a) 4.3-10+ RF Connector [7] and (b) M-LOC Cluster/multiport connector [8] ..... | 65 | +| 26 | Figure 2.3.5-1 Mechanical Enclosure Front View ..... | 66 | +| 27 | Figure 2.3.5-2 Mechanical Enclosure Top View ..... | 66 | +| 28 | Figure 2.3.6-1 Power Reference Design ..... | 68 | +| 29 | Figure 2.3.8-1 Integrated O-DU & O-RU (gNB-DU) Reference Design ..... | 70 | +| 30 | Figure 2.4.1-1 Functional Block Diagram For O-DU portion ..... | 71 | +| 31 | Figure 2.4.2-1 Functional Block Diagram for O-RU portion ..... | 72 | +| 32 | Figure 2.4.2-2 Phased array antenna reference design ..... | 73 | +| 33 | Figure 2.5.1-1 [N <sub>x</sub> M]T[N <sub>x</sub> M]R mMIMO O-RU <sub>7-2x</sub> High Level System Architecture #1 ..... | 76 | +| 34 | Figure 2.5.1-2 [N <sub>x</sub> M]T[N <sub>x</sub> M]R mMIMO O-RU <sub>7-2x</sub> High Level System Architecture #2 ..... | 77 | +| 35 | Figure 2.5.1-3 [N <sub>x</sub> M]T[N <sub>x</sub> M]R mMIMO O-RU <sub>7-2x</sub> High Level System Architecture #3 ..... | 77 | +| 36 | Figure 2.5.2-1 mMIMO O-RU <sub>7-2x</sub> hardware reference design architecture example of 32T32R ..... | 78 | +| 37 | Figure 2.5.2-2 mMIMO O-RU <sub>7-2x</sub> hardware reference design architecture example of 64T64R ..... | 79 | +| 38 | Figure 2.5.2-3 mMIMO O-RU <sub>7-2x</sub> Digital processing unit architecture example ..... | 80 | +| 39 | Figure 2.5.2-4 mMIMO O-RU <sub>7-2x</sub> RF front end architecture example of 32T32R ..... | 81 | +| 40 | Figure 2.5.2-5 mMIMO O-RU <sub>7-2x</sub> RF front end architecture example of 64T64R ..... | 82 | +| 41 | Figure 2.5.2-6 mMIMO O-RU <sub>7-2x</sub> antenna array architecture example of 32T32R ..... | 83 | +| 42 | Figure 2.5.2-7 mMIMO O-RU <sub>7-2x</sub> antenna array architecture example of 64T64R ..... | 84 | + +| | | | +|---|------------------------------------------------------------------------------------------------------------------|----| +| 1 | Figure 2.5.2-8 mMIMO antenna array view (a) simulation model of 192 reflector backed antenna element array only | | +| 2 | and (b) 32T32R mMIMO O-RU <sub>7-2x</sub> Antenna array prototype [14]..... | 85 | +| 3 | Figure 2.5.3-1 Mechanical enclosure..... | 86 | +| 4 | Figure 2.5.3-2 Exploded views of mechanical architecture/stacking examples (a) design #1 and (b) design #2 ..... | 87 | + +5 + +# Tables + +6 + +| | | | +|----|------------------------------------------------------------------------|----| +| 7 | Table 2.2.2-1 Processor Feature List ..... | 20 | +| 8 | Table 2.2.2-2 Memory Channel Feature List..... | 20 | +| 9 | Table 2.2.2-3 Accelerator Hardware Features ..... | 21 | +| 10 | Table 2.2.2-4 Hardware Accelerator Firmware Features..... | 22 | +| 11 | Table 2.2.2-5 Accelerator Hardware Features ..... | 23 | +| 12 | Table 2.2.2-6 Hardware Accelerator Firmware Features..... | 24 | +| 13 | Table 2.2.2-7 Accelerator Hardware Feature List ..... | 25 | +| 14 | Table 2.2.2-8 Accelerator Firmware Feature List..... | 25 | +| 15 | Table 2.2.4-1 External Port List ..... | 27 | +| 16 | Table 2.2.7-1 O-DU Power Requirements..... | 31 | +| 17 | Table 2.2.9-1 Environmental Features..... | 31 | +| 18 | Table 2.3.2-1 FPGA Interface Requirements ..... | 37 | +| 19 | Table 2.3.2-2 FPGA Functional Blocks..... | 38 | +| 20 | Table 2.3.2-3 RF Processing Unit Interface Specifications..... | 39 | +| 21 | Table 2.3.2-4 JESD204B/C Serial Data Rates..... | 39 | +| 22 | Table 2.3.2-5 Transceiver RF Specifications..... | 40 | +| 23 | Table 2.3.2-6 Interface Requirements..... | 44 | +| 24 | Table 2.3.2-7 OPU-DPU Functional Blocks..... | 45 | +| 25 | Table 2.3.2-8 Power Amplifier Interface Specifications ..... | 45 | +| 26 | Table 2.3.2-9 Power Amplifier RF Specifications..... | 46 | +| 27 | Table 2.3.2-10 LNA Interfaces ..... | 46 | +| 28 | Table 2.3.2-11 LNA RF Specifications ..... | 47 | +| 29 | Table 2.3.2-12 Circulator Specifications ..... | 48 | +| 30 | Table 2.3.2-13 Omnidirectional Antenna Specifications..... | 49 | +| 31 | Table 2.3.2-14 Directional Antenna Specifications..... | 50 | +| 32 | Table 2.3.2-15 JESD204 Abridged Lexicon..... | 52 | +| 33 | Table 2.3.2-16 4T4R Example Data Mapping..... | 55 | +| 34 | Table 2.3.3-1 Synchronization and Timing Interface Specifications..... | 58 | +| 35 | Table 2.3.3-2 Synchronizer Interface Specifications ..... | 59 | +| 36 | Table 2.3.3-3 Synchronizer Performance Specifications..... | 59 | +| 37 | Table 2.3.3-4 Synthesizer Interface Specifications..... | 60 | +| 38 | Table 2.3.3-5 TCXO Clock Performance Specifications..... | 61 | + +| | | | +|---|------------------------------------------------------------------|----| +| 1 | Table 2.3.4-1 External Port List ..... | 63 | +| 2 | Table 2.3.6-1 Transceiver Module Specifications ..... | 67 | +| 3 | Table 2.3.6-2 RF Front End Module Specifications ..... | 67 | +| 4 | Table 2.3.7-1 Thermal Conductivity of common Metals [9] ..... | 68 | +| 5 | Table 2.3.7-2 Convective heat transfer coefficient [10] ..... | 69 | +| 6 | Table 2.3.7-3 Emissivity value of different materials [11] ..... | 69 | +| 7 | Table 2.3.8-1 Environmental Features ..... | 70 | +| 8 | | | + +--- + +## Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +--- + +## Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in O-RAN deliverables except when used in direct citation. + +# Chapter 1      Introductory Material + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG7 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +x the first digit is incremented for all changes of substance, i.e., technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). + +y the second digit is incremented when editorial only changes have been incorporated in the document. + +z the third digit included only in working versions of the document indicating incremental changes during the editing process. This variable is for internal WG7 use only. + +The present document specifies system requirements and high-level architecture for the FR1 Outdoor Macrocell deployment scenario as specified in the Deployment Scenarios and Base Station Classes document [1]. + +In the main body of this specification (in any “chapter”) the information contained therein is informative, unless explicitly described as normative. Information contained in an “Annex” to this specification is always informative unless otherwise marked as normative. + +## 1.2 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +[1] ORAN-WG7.DSC.0-V03.00 Technical Specification, ‘Deployment Scenarios and Base Station Classes for White Box Hardware’. <https://www.o-ran.org/specifications>. + +[2] [3GPP TR 21.905: "Vocabulary for 3GPP Specifications"](#). + +[3] 3GPP TS 38.104: "NR; Base Station (BS) radio transmission and reception". + +[4] ORAN-WG4.CUS.0-v01.00 Technical Specification, ‘O-RAN Fronthaul Working Group Control, User and Synchronization Plane Specification’. <https://www.o-ran.org/specifications> + +- [5] 3GPP TS 38.113:"NR: Base Station (BS) Electromagnetic Compatibility (EMC)". +[http://www.3gpp.org/ftp//Specs/archive/38\\_series/38.113/38113-f80.zip](http://www.3gpp.org/ftp//Specs/archive/38_series/38.113/38113-f80.zip) +- [6] [O-RAN-WG7 OMAC Hardware Architecture Description - v02.00](#) Technical Specification 'Outdoor Macrocell Hardware Architecture and Requirements (FR1) Specification' +- [7] [https://www.rosenberger.com/0\\_documents/de/catalogs/ba\\_communication/catalog\\_coax/15\\_Chapter\\_43-10\\_41-95.pdf](https://www.rosenberger.com/0_documents/de/catalogs/ba_communication/catalog_coax/15_Chapter_43-10_41-95.pdf) +- [8] <https://www.commscope.com/product-type/cable-assemblies/wireless-cable-assemblies/coaxial-cable-assemblies/itemmloc-f1xm-4/> +- [9] Zhong, J., Liu, D., Li, Z., & Sun, X. (2012, August). High thermal conductivity materials and their application on the electronic products. In 2012 IEEE Asia-Pacific Conference on Antennas and Propagation (pp. 173-175). IEEE. +- [10] [https://www.engineersedge.com/heat\\_transfer/convective\\_heat\\_transfer\\_coefficients\\_13378.htm](https://www.engineersedge.com/heat_transfer/convective_heat_transfer_coefficients_13378.htm) +- [11] <https://www.thermoworks.com/emissivity-table/> +- [12] "Serial Interface for Data Converters", JESD204C.1, December 2021, [www.jedec.org](http://www.jedec.org) +- [13] "JESD204x Frame Mapping Table Generator", <https://www.analog.com/en/license/licensing-agreement/jesd204x-frame-mapping-table-generator.html> + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [1] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in 3GPP TR 21.905 [2]. For the base station classes of Pico, Micro and Macro, the definitions are given in 3GPP TR 38.104 [3]. + +**Carrier Frequency:** Center frequency of the cell. + +**F1 interface:** The open interface between O-CU and O-DU defined by 3GPP TS 38.473. + +**Frequency Band:** A designated frequency range for the operation of the base station and the UE radios. 5G NR frequency bands are divided into two different frequency ranges: Frequency Range 1 (FR1) that mainly includes sub-6GHz frequency bands, some of which are bands traditionally used by previous standards but has been extended to cover potential new spectrum offerings from 410MHz to 7125MHz; Frequency Range 2 (FR2) that includes frequency bands from 24.25 GHz to 52.6 GHz. Bands in this millimeter wave range have shorter range but higher available bandwidth than bands in the FR1. + +**Frequency Range:** It refers to bandwidth defined by the frequency range within which the Base Station can be operated, defined by the band-pass filter of the BS; e.g., 3.4 – 3.8 GHz (400 MHz) + +**Fronthaul Gateway (FHGW):** A fronthaul gateway is a physical entity that is located between a distributed unit and one or more radio units where it distributes, aggregates, and/or converts fronthaul protocols between the distributed unit and multiple radio units. + +**gNB:** A RAN node providing NR user plane and control plane protocol terminations towards the UE, and connected via the NG interface to the 5GC. + +**Integrated architecture:** In the integrated architecture, the O-RU and O-DU are implemented on one platform. Each O-RU and RF front end is associated with one O-DU. They are then aggregated to O-CU and connected by F1 interface. + +**Split architecture:** The O-RU and O-DU are physically separated from one another in this architecture. A switch may aggregate multiple O-RUs to one O-DU. O-DU, switch and O-RUs are connected by the front haul interface as defined in WG4. + +## 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in [2] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, as in [2]. + +| | | +|-------|------------------------------------------------------------------------------------| +| 7-2x | Fronthaul interface split option as defined by O-RAN WG4, also referred to as 7-2x | +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth-Generation Mobile Communications | +| ADC | Analog to Digital Converter | +| AFE | Analog Front End | +| AFU | Antenna Filter Unit | +| ASIC | Application Specific Integrated Circuit | +| BBDEV | Baseband Device | +| BH | Backhaul | +| BMC | Baseboard Management Controller | +| BPSK | Binary Phase Shift Keying | +| BS | Base Station | +| CISPR | International Special Committee on Radio Interference | +| CFR | Crest Factor Reduction | + +| | | | +|----|-------------------|-------------------------------------------------------------------------------------------| +| 1 | CU | Centralized Unit as defined by 3GPP | +| 2 | COM | Cluster Communication | +| 3 | CPRI | Common Public Radio Interface | +| 4 | CPU | Central Processing Unit | +| 5 | CRC | Cyclic Redundancy Check | +| 6 | DAC | Digital to Analog Converter | +| 7 | DDC | Digital Down Conversion | +| 8 | DDR | Double Data Rate | +| 9 | DFE | Digital Front End | +| 10 | DIMM | Dual-Inline-Memory-Modules | +| 11 | DL | Downlink | +| 12 | DPD | Digital Pre-Distortion | +| 13 | DPDK | Data Plane Development Kit | +| 14 | DSP | Digital Signal Processor | +| 15 | DU | Distributed Unit as defined by 3GPP | +| 16 | DUC | Digital Up Conversion | +| 17 | ECC | Error Correcting Code | +| 18 | EMI | Electromagnetic Interference | +| 19 | eCPRI | evolved Common Public Radio Interface | +| 20 | EMC | Electro Magnetic Compatibility | +| 21 | EVM | Error Vector Magnitude | +| 22 | FCC | Federal Communications Commission | +| 23 | FEC | Forward Error Correction | +| 24 | FFT | Fast Fourier Transform | +| 25 | FH | Fronthaul | +| 26 | FHGW | Fronthaul Gateway | +| 27 | FHGW <sub>x</sub> | Fronthaul gateway with no FH protocol translation, supporting an O-DU with split option x | +| 28 | | and an O-RU with split option x, with currently available options 6→6, 7-2x→7-2x and 8→8 | + +| | | | +|----|---------------------|------------------------------------------------------------------------------------------| +| 1 | FHGW <sub>x→y</sub> | Fronthaul Gateway that can translate fronthaul protocol from an O-DU with split option x | +| 2 | | to an O-RU with split option y, with currently available option 7-2x→8. | +| 3 | FHHL | Full Height Half Length | +| 4 | FPGA | Field Programmable Gate Array | +| 5 | GbE | Gigabit Ethernet | +| 6 | GNSS | Global Navigation Satellite System | +| 7 | GPP | General Purpose Processor | +| 8 | GPS | Global Positioning System | +| 9 | HARQ | Hybrid Automatic Repeat request | +| 10 | HHHL | Half Height Half Length | +| 11 | IP67 | Ingress Protection 67 | +| 12 | IEEE | Institute of Electrical and Electronics Engineers | +| 13 | IFFT | Inverse Fast Fourier Transform | +| 14 | IMD | Inter Modulation Distortion | +| 15 | I/O | Input/Output | +| 16 | JTAG | Joint Test Action Group | +| 17 | L1 | Layer 1 | +| 18 | LDPC | Low-Density Parity Codes | +| 19 | LDO | Low dropout | +| 20 | LRDIMM | Load-Reduced Dual In-line Memory Module | +| 21 | LTE | Long Term Evolution | +| 22 | LVDS | Low-Voltage Differential Signaling | +| 23 | MAC | Media Access Control | +| 24 | MCP | Multi-Chip Package | +| 25 | MH | Midhaul | +| 26 | MIG | Memory Interface Generator | +| 27 | MII | Media-Independent interface | +| 28 | MIMO | Multiple Input Multiple Output | + +| | | | +|----|-------------------|------------------------------------------------------------------------------------------------| +| 1 | MU-MIMO | Multiple User MIMO | +| 2 | NEBS | Network Equipment-Building System | +| 3 | NetConf | Network Configuration Protocol | +| 4 | NFV | Network Functions Virtualization | +| 5 | NIC | Network Interface Controller | +| 6 | NR | New Radio | +| 7 | O-CU | O-RAN Centralized Unit as defined by O-RAN | +| 8 | O-DU <sub>x</sub> | A specific O-RAN Distributed Unit having fronthaul split option x where x may be 6, 7-2x (as | +| 9 | | defined by WG4) or 8 | +| 10 | O-RU <sub>x</sub> | A specific O-RAN Radio Unit having fronthaul split option x, where x is 6, 7-2x (as defined by | +| 11 | | WG4) or 8, and which is used in a configuration where the fronthaul interface is the same | +| 12 | | at the O-DU <sub>x</sub> | +| 13 | OCXO | Oven Controlled Crystal Oscillator | +| 14 | ORx | Observation Receiver | +| 15 | PAM | Power Amplifier Module | +| 16 | PCIe | Peripheral Component Interconnect express | +| 17 | PDCP | Packet Data Convergence Protocol | +| 18 | pFIR | Programable Finite Impulse Response filter | +| 19 | PHY | Physical Layer | +| 20 | PIM | Passive Intermodulation | +| 21 | PMBus | Power Management Bus | +| 22 | POE | Power over Ethernet | +| 23 | PPS | Pulse Per Second | +| 24 | PRACH | Physical Random-Access Channel | +| 25 | QAM | Quadrature Amplitude Modulation | +| 26 | QPSK | Quadrature Phase Shift Keying | +| 27 | QSFP | Quad Small Form-factor Pluggable | +| 28 | RAN | Radio Access Network | + +| | | | +|----|-------|--------------------------------------------| +| 1 | RDIMM | Registered Dual In-line Memory Module | +| 2 | RF | Radio Frequency | +| 3 | RFIC | Radio Frequency Integrated Circuit | +| 4 | RoE | Radio over Ethernet | +| 5 | RU | Radio Unit as defined by 3GPP | +| 6 | RX | Receiver | +| 7 | SATA | Serial ATA | +| 8 | SDU | Service Data Unit | +| 9 | SFP | Small Form-factor Pluggable | +| 10 | SFP+ | Small Form-factor Pluggable plus | +| 11 | SOC | System On Chip | +| 12 | SPI | Serial Peripheral Interface | +| 13 | SSD | Solid State Drive | +| 14 | TCXO | Temperature Compensated Crystal Oscillator | +| 15 | TDP | Thermal Design Power | +| 16 | TR | Technical Report | +| 17 | TS | Technical Specification | +| 18 | TX | Transmitter | +| 19 | UL | Uplink | +| 20 | USB | Universal Serial Bus | +| 21 | WG | Working Group | + +--- + +## Chapter 2 Hardware Reference Design 1 + +This chapter describes one example of white box hardware reference design including O-DU, O-RU. + +### 2.1 O-CU Hardware Reference Design + +The O-CU white box hardware is the platform that performs the O-CU function of upper L2 and L3. The hardware systems specified in this document meet the computing, power and environmental requirements of use cases configurations and feature sets of RAN physical node. These requirements are described in the hardware requirement specification in addition to the deployment scenarios document. The O-CU hardware includes the chassis platform, mother board, peripheral devices, and cooling devices. The mother board contains processing unit, memory, the internal I/O interfaces, and external connection ports. The midhaul (MH) and backhaul (BH) interface are used to carry the traffic between O-CU and O-DU as well as O-CU and core network. The other hardware functional components include: the storage for software, hardware and system debugging interfaces, board management controller, just to name a few; the O-CU designer will make decision based on the specific needs of the implementation. + +The HW reference design of O-CU is the same as O-DU except for the need of a HW accelerator, thus the detail design will be described in O-DU section 2.2. + +#### 2.1.1 O-CU High-Level Functional Block Diagram + +[Intentionally left blank. Refer to O-DU Functional Block Diagram] + +## 1 2.1.2 O-CU Hardware Components + +### 2 2.1.2.1 Digital Processing Unit + +### 3 2.1.2.2 Hardware Accelerator (If required by design) + +#### 4 2.1.2.2.1 Accelerator Design 1 + +#### 5 2.1.2.2.2 Accelerator Design 2 + +## 6 2.1.3 Synchronization and Timing + +## 7 2.1.4 External Interface Ports + +## 8 2.1.5 O-CU Firmware (if needed) + +## 9 2.1.6 Mechanical + +## 10 2.1.7 Power Unit + +## 11 2.1.8 Thermal + +## 12 2.1.9 Environmental and Regulations + +## 13 2.2 O-DU Hardware Reference Design + +14 The O-DU white box hardware is the platform that performs the O-DU functions such as upper L1 and lower +15 L2 functions. The hardware systems specified in this document meet the computing, power and +16 environmental requirements of use case's configurations and feature sets of RAN physical node. These +17 requirements are described in the early hardware requirement specification as well as in the use cases +18 document. The O-DU hardware includes the chassis platform, mother board, peripheral devices, and cooling +19 devices. The mother board contains processing unit, memory, the internal I/O interfaces, and external +20 connection ports. The fronthaul and backhaul interface are used to carry the traffic between O-RU/FHGW<sub>7-2</sub>/FHGW<sub>7-2</sub>→<sub>8</sub> and O-DU as well as O-CU and O-DU. The O-DU design may also provide an interface for +21 hardware accelerator if that option is preferred. The other hardware functional components include: the +22 storage for software, hardware and system debugging interfaces, board management controller, just to +23 name a few; the O-DU designer will make decision based on the specific needs of the implementation. + +25 Note that the O-DU HW reference design is also feasible for O-CU and integrated O-CU/ O-DU. + +Image: O-RAN Alliance Logo + +O-RAN.WG7.OMAC-HRD.0-R003-v03.00 + +## 2.2.1 O-DU High-Level Functional Block Diagram + +In the following O-DU/O-CU mother board functional block diagram, it shows the interconnections of the major components and external interfaces. The digital processing unit or SoC (CPU) handles the baseband processing workload. To make the processing more efficient, an accelerator can be used to assist with the baseband workload processing. The memory devices include random-access memory (RAM) for temporary storage of data while flash memory is used for codes and logs. The storage device is for persistent storage. The external network cards can be used for fronthaul or backhaul connection. The baseboard management controller (BMC) is a microcontroller which monitors hardware operation on the motherboard. The clock circuits provide digital processing unit with required clock signals. + +![Figure 2.2.1-1 O-DU/O-CU Functional Block Diagram](602137eca0727354016f142d754cb265_img.jpg) + +Detailed description of the diagram for reconstruction + +The diagram shows CPU1 connected to various components: + - DDR5 memory channels (CPU1-D1, CPU1-C1, CPU1-B1, CPU1-A1 on the left; CPU1-E1, CPU1-F1, CPU1-G1, CPU1-H1 on the right) via 4800 MT/s 1PPC interfaces. + - VR14 8 PHASE power delivery. + - PCIe Gen5 X8 links to SXB2 (WIO-R) and MCIO x8 / 2x NVMe. + - PCIe Gen5 X32 link to SXB1 (WIO-L). + - Multiple PCIe Gen5 X8 links to JNVME1, JNVME2, JNVME3, JNVME4 MCIO connectors. + - DMI3 / DMI X4 link to PCH (Platform Controller Hub). + - PCH connects to: + - SlimSAS (6.0 Gb/s SATA 0-7) + - SATA-DOM SATA (6.0 Gb/s SATA 16-17) + - Rear USB 3.0 x 2, Rear USB 2.0 (RJ45) x 2, TypeA USB 2.0 x 1, USB 3.0 x 2 Header via ASM3042 PCIe G2 X1 bridge. + - M.2 slot via PCIe G3 X2. + - TPM HEADER Debug Card via SPI. + - CPLD via SPI, SPI0, eMMC. + - BIOS via SPI. + - BMC AST2600 via PCIe GEN2 X1, USB 2.0, eSPI. + - 1G LAN I210 controllers via PCIe GEN2 X1. + - 10G LAN X550-AT2 via PCIe GEN3 X4. + - BMC AST2600 connects to: + - PHY of Dedicated LAN via RGMII / NC-SI. + - JNCSI Header. + - DDR4 memory. + - Temperature Sensor TMP432 (RT1/RT2). + - TPM via FWSPI. + - BMC F/W flash. + +Figure 2.2.1-1 O-DU/O-CU Functional Block Diagram + +Figure 2.2.1-1 O-DU/O-CU Functional Block Diagram + +| | | +|---------------------------------------------------------------------------------------------------------------------------|----| +| © 2023 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. | 19 | +|---------------------------------------------------------------------------------------------------------------------------|----| + +## 2.2.2 O-DU Hardware Components + +### 2.2.2.1 Digital Processing Unit + +The example of general-purpose processor performances and other related information are listed in the following table. + +**Table 2.2.2-1 Processor Feature List** + +| Item Name | Description | +|--------------------------------------------|-------------| +| # of Cores | 24 | +| # of Threads | 48 | +| Base Frequency | 1.90GHZ | +| Max Turbo Frequency | 3.90GHz | +| Cache | 45MB | +| TDP | 165W | +| Max Memory Size (dependent on memory type) | 2TB | +| Memory Types | DDR5 | +| Max # of Memory Channels | 8 | + +#### 2.2.2.1.1 Interfaces + +These are the required interface specification for the main board. + +##### 2.2.2.1.1.1 Memory Channel Interfaces + +The system memory capacity, type and related information is described in the following table. + +**Table 2.2.2-2 Memory Channel Feature List** + +| Item Name | Description | +|----------------------|--------------------------------| +| Memory Types | DDR5 | +| # of Memory Channels | 8 | +| ECC RDIMM\LRDIMM | Up to 128GB | +| 3DS ECCRDIMM | Up to 256GB | +| Memory Speed | up to 4800MT/s | +| DIMM Sizes | 256GB, 128GB, 64GB, 32GB, 16GB | +| Memory Voltage | 1.1 V | + +##### 2.2.2.1.1.2 PCIe + +PCIe Gen 5 is supported by the processor. There is a total of 80 PCIe lanes available on the motherboard which are allocated as per Figure 2.2.1-1 O-DU/O-CU Functional Block Diagram. This example has 2 x PCIe Gen5 x 16 Full Height Full Length expansion slots and 1 x PCIe Gen5 x 16 Low Profile expansion slot. Each 16-lane bi-directional PCIe expansion slot has 128GB/s of available bandwidth. + +### 2.2.2.1.3 Ethernet + +The system should be capable of offering a minimum aggregated 48 Gbps Ethernet bandwidth. The breakdown of the Ethernet ports is discussed in a later section. + +## 2.2.2.2 Hardware Accelerator (if required by design) + +### 2.2.2.2.1 Hardware Accelerator + +Hardware accelerators can be used in O-DU to offload computationally intensive functions and to optimize the performance under varying traffic and loading conditions. While the hardware acceleration functional requirements and implementation are system designer's choice; the O-DU is required to meet the minimum system performance requirements under various loading conditions and deployment scenarios. In most cases, a Field Programmable Gate Array (FPGA) or Application Specific Integrated Circuit (ASIC) based PCIe card can be used to optimize the system performance. FPGA(s) and ASIC(s) may be part of a Network Interface Controller (NIC) that further provides connectivity services. + +#### 2.2.2.2.2 Accelerator Design 1 + +The O-DU system is typically implemented using a multi-core processor and one or more hardware accelerators. Parts of O-DU protocol stack can be implemented in software running on the multi-core processors and the computationally intensive L1 and L2 functions can be offloaded to an FPGA-based hardware accelerator. This accelerator comprises two FPGAs for L1 offload and fronthaul connectivity in lookaside mode. The accelerator hardware and firmware features are listed in Table 2.2.2-3 and Table 2.2.2-4. + +**Table 2.2.2-3 Accelerator Hardware Features** + +| SoC Resources | FPGA1 | FPGA2 | +|-----------------------------|-----------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------| +| | System Logic cells - 930K<br>CLB LUT - 425K<br>SDFEC -8<br>DSP Slices - 4,272<br>BRAM - 38.0Mb<br>URAM - 22.5Mb | System Logic cells - 1,143K<br>CLB LUT - 523K<br>CLB Flip-Flops -1,045K<br>DSP Slices - 1,968<br>BRAM - 34.6Mb<br>URAM - 36.0Mb | +| Form Factor | FHHL PCIe Form Factor | | +| PCIe Interface | Gen 3 x16 with Bifurcation | | +| On Board Memory | FPGA1 | FPGA2 | +| | Total Capacity 4 GB in PL, upgradeable to 8GB<br>Total Capacity 2 GB in PS, upgradeable to 4GB | Total Capacity 4 GB in PL, upgradeable to 8GB<br>Total Capacity 2 GB in PS, upgradeable to 4GB | +| Network Interface(s) | 2xSFP28 optical interfaces to FPGA2<br>(User Configurable, includes 10/25 Ethernet) | | +| Other External Interface(s) | Micro USB for JTAG support (FPGA programming and debug) and access to BMC | | + +| | | +|-----------------------------|------------------------------------------------------------------------------------------------------------------------------| +| Graphical User interface | GUI for monitoring the basic board parameters, monitoring temperature alerts, firmware upgrades for BMC | +| Board Management Controller | Telemetry, Security, Remote Upgrade | +| Clocking | O-RAN C1, C2, C3, C4 | +| Fronthaul | eCPRI, RoE IEEE1914.3, O-RAN WG4 FH | +| GPS | SMA for 1 PPS (In/Out) | +| Operating Temperature | NEBS Compliant | +| Power | < 75 W | +| Clocking Options | Low-Jitter, configurable clock ranging from 10MHz to 750MHz<br>1 PPS input and output with assembly option for OCXO and TCXO | + +**Table 2.2.2-4 Hardware Accelerator Firmware Features** + +| Item Name | Description | +|--------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Remote System Upgrade | Securely upgradable FPGA flash image | +| L1 Acceleration | 5G NR LDPC encoding/decoding with interleaving/de-interleaving and rate-matching/rate-de-matching along with early termination, CRC attachment, and HARQ management | +| Hardware-Software APIs | Fully compliant with DPDK/BBDEV APIs | +| Fronthaul Protocols/Compression | Fully compliant with O-RAN WG4 MCUS-planes Specifications | +| Open Programmable Acceleration Environment | Support for: <ul style="list-style-type: none"> <li>FPGA flashing upgrade</li> <li>Firmware version reporting</li> <li>PCIe diagnostics</li> <li>Ethernet diagnostics</li> <li>Temperature and voltage telemetry information</li> </ul> | + +The hardware accelerator supports x86 or non-x86-based processors. Figure 2.2.2-1 illustrates the two-chip acceleration architecture comprising two FPGAs with multi-lane PCIe interfaces toward the CPU and external connectivity toward O-RU(s) via eCPRI and O-CU(s) through GbE connectivity. The example architecture further depicts multi-lane Gen3 PCIe interfaces between each FPGA and the CPU. The FPGAs communicate through high-bandwidth Ethernet (GbE) transport. + +![Figure 2.2.2-1 Dual-chip FPGA-based Hardware Acceleration in O-DU. The diagram shows an X86 or ARM-based CPU (L2 and Partial L1) connected to two FPGAs. FPGA1 (L1 Offload) and FPGA2 (Connectivity) are connected via an Inter-Chip Interface (100G Ethernet). The CPU is connected to FPGA1 via a [Bifurcated] PCIe Interface (PCIe Gen3x16 100G). FPGA2 is connected to the Fronthaul Interface (10/25G Ethernet/eCPRI).](6c05557f1d72e467b7418e58a05b7993_img.jpg) + +``` + +graph LR + CPU["X86 or ARM-based CPU +(L2 and Partial L1)"] + subgraph Accelerator + FPGA1["FPGA1 +(L1 Offload)"] + FPGA2["FPGA2 +(Connectivity)"] + FPGA1 ---|Inter-Chip Interface +100G Ethernet| FPGA2 + end + CPU <-->|"[Bifurcated] PCIe Interface +PCIe Gen3x16 100G"| FPGA1 + FPGA2 <-->|Fronthaul Interface +10/25G Ethernet/eCPRI| FH[" "] + style FH fill:none,stroke:none + +``` + +Figure 2.2.2-1 Dual-chip FPGA-based Hardware Acceleration in O-DU. The diagram shows an X86 or ARM-based CPU (L2 and Partial L1) connected to two FPGAs. FPGA1 (L1 Offload) and FPGA2 (Connectivity) are connected via an Inter-Chip Interface (100G Ethernet). The CPU is connected to FPGA1 via a [Bifurcated] PCIe Interface (PCIe Gen3x16 100G). FPGA2 is connected to the Fronthaul Interface (10/25G Ethernet/eCPRI). + +**Figure 2.2.2-1 Dual-chip FPGA-based Hardware Acceleration in O-DU** + +#### 2.2.2.2.3 Accelerator Design 2 + +The O-DU system is typically implemented using a multi-core processor (CPU) and one or more hardware accelerators. Parts of O-DU protocol stack can be implemented in software running on the multi-core processors and the computationally intensive L1 and L2 functions can be offloaded to an FPGA-based hardware accelerator. This accelerator comprises a single FPGA for L1 offload in lookaside mode. The accelerator hardware and firmware features are listed in Table 2.2.2-5 and Table 2.2.2-6. + +**Table 2.2.2-5 Accelerator Hardware Features** + +| | | +|-----------------------------|-----------------------------------------------------------------------------------------------------------------| +| SoC Resources | System Logic cells - 930K<br>CLB LUT - 425K<br>SDFEC -8<br>DSP Slices - 4,272<br>BRAM - 38.0Mb<br>URAM - 22.5Mb | +| Form Factor | HHHL PCIe Form Factor | +| PCIe Interface | Gen 3 x16 (Gen4 x8) | +| On Board Memory | Total Capacity 4 GB in PL, upgradeable to 8GB<br>Total Capacity 2 GB in PS, upgradeable to 4GB | +| Other External Interface(s) | Micro USB for JTAG support (FPGA programming and debug) and access to BMC | +| Graphical User interface | GUI for monitoring the basic board parameters, monitoring temperature alerts, firmware upgrades for BMC | + +| | | +|-----------------------------|-------------------------------------| +| Board Management Controller | Telemetry, Security, Remote Upgrade | +| Operating Temperature | NEBS Compliant | +| Power | < 35 W | + +**Table 2.2.2-6 Hardware Accelerator Firmware Features** + +| | | +|--------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Remote System Upgrade | Securely upgradable FPGA flash image | +| L1 Acceleration | 5G NR LDPC encoding/decoding with interleaving/de-interleaving and rate-matching/rate-de-matching along with early termination, CRC attachment, and HARQ management | +| Hardware-Software APIs | Fully compliant with DPDK/BBDEV APIs | +| Open Programmable Acceleration Environment | Support for: <ul style="list-style-type: none"> <li>FPGA flashing upgrade</li> <li>Firmware version reporting</li> <li>PCIe diagnostics</li> <li>Ethernet diagnostics</li> <li>Temperature and voltage telemetry information</li> </ul> | + +The hardware accelerator supports x86 or non-x86-based processors. Figure 2.2.2-2 illustrates the single-chip acceleration architecture comprising one FPGA with Gen3 x16 or Gen4 x8 PCIe interfaces toward the CPU. + +![Figure 2.2.2-2 Single-chip FPGA-based Hardware Acceleration in O-DU. The diagram shows an X86 or ARM-based CPU (L2 and Partial L1) connected to an FPGA (L1 Offload) via a PCIe Interface (PCIe Gen3x16 or Gen4 x8 100G). The CPU is also connected to an F1 Interface Ethernet (10/25G) via a dashed line.](f55f0b7209d3d339e6ab712e92ac917e_img.jpg) + +``` + +graph LR + CPU["X86 or ARM-based CPU +(L2 and Partial L1)"] + FPGA["FPGA +(L1 Offload)"] + F1["F1 Interface +Ethernet (10/25G)"] + PCIe["PCIe Interface +PCIe Gen3x16 or Gen4 x8 +100G"] + + CPU <--> F1 + CPU <--> PCIe + PCIe <--> FPGA + +``` + +Figure 2.2.2-2 Single-chip FPGA-based Hardware Acceleration in O-DU. The diagram shows an X86 or ARM-based CPU (L2 and Partial L1) connected to an FPGA (L1 Offload) via a PCIe Interface (PCIe Gen3x16 or Gen4 x8 100G). The CPU is also connected to an F1 Interface Ethernet (10/25G) via a dashed line. + +**Figure 2.2.2-2 Single-chip FPGA-based Hardware Acceleration in O-DU** + +#### 2.2.2.2.4 Accelerator Design 3 + +This design includes an Embedded NIC Inline Accelerator (ENIAC) with an ASIC that can provide NIC functions. One option supports a high-capacity O-DU using multiple PCIe cards in standard racks and aligns with the FAPI interface to maximize software reuse. The second option supports a high-capacity O-DU using an Ethernet-based backplane interconnect and aligns with the nFAPI interface to maximize software reuse. ENIAC unloads L1 from the host, allowing it to focus on L2. + +### a. Accelerator Requirements + +Hardware and firmware requirements for this accelerator design are given in Table 2.2.2-7 and Table 2.2.2-8, respectively. + +**Table 2.2.2-7 Accelerator Hardware Feature List** + +| Item Name | Description | +|-----------------------------------------------|-------------------------------------------------------------------------------------------------| +| PCIe (Interface with digital processing unit) | Gen4 x16 (and lower) | +| Form factor | FHHL | +| Connectivity | QSFP28/SFP | +| NIC Device | 200Gb xHAUL for FH, BH & MH traffic shaping. | +| DDR Main | TBD GB DDR4 | +| Flash (FPGA images) | >=1 Gbit | +| BMC | Telemetry, Security, remote upgrade | +| Clocking | For O-RAN C1, C2, C3 & C4 | +| Fronthaul | eCPRI, RoE IEEE1914.3, O-RAN WG4 | +| GPS | SMA for 1 PPS & 10MHz (in/out) | +| Operating Temperature (ambient) | NEBS Compliant | +| Power | <75W | +| Clock Accuracy | Low-Jitter, configurable clock ranging from 10MHz to 750MHz. Option for OCXO (TCXO as standard) | + +**Table 2.2.2-8 Accelerator Firmware Feature List** + +| Item Name | Description | +|--------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Remote system upgrade | Securely upgradable image | +| Queuing | Command queuing at FAPI interface | +| LDPC Acceleration | Rel15 compliant | +| Fronthaul Compression | In-line compression/decompression for Mu-Law, block-floating point, and quantization according to the O-RAN WG4 specification. | +| Open programmable acceleration environment | Support for: <ul style="list-style-type: none"> <li>Flashing upgrade</li> <li>Firmware version reporting</li> <li>PCIe diagnostics</li> <li>Ethernet diagnostics</li> <li>Temperature and voltage telemetry information.</li> </ul> | + +### b. Accelerator Design + +Figure 2.2.2-3 illustrates Accelerator Design 3 with integrated NIC and PCIe connectivity to L2. + +Figure 2.2.2-4 illustrates Accelerator Design 3 with integrated NIC and Ethernet connectivity to L2. + +![Figure 2.2.2-3 Accelerator Design 3 using PCIe](58c0f87982f518b51c65048b682e7b36_img.jpg) + +Diagram illustrating Accelerator Design 3 using PCIe. The architecture consists of three main components: L2 Processing, Timing, and L1 Upper Phy Accelerator. + +- L2 Processing** and **Timing** are connected to the **L1 Upper Phy Accelerator** via **FAPI on PCIe4x16** and **PPS 10 MHz** respectively. +- The **L1 Upper Phy Accelerator** is connected to the external network via **O-RAN 7-2x**, **eCPRI FH QSFP28**, **200 Gbps+ Ethernet**, and **SyncE**. + +Figure 2.2.2-3 Accelerator Design 3 using PCIe + +Figure 2.2.2-3 Accelerator Design 3 using PCIe + +![Figure 2.2.2-4 Accelerator Design 3 using Ethernet](4aebbe7212644be7d742c6c05f6e4db4_img.jpg) + +Diagram illustrating Accelerator Design 3 using Ethernet. The architecture consists of three main components: L2 Processing, Timing, and L1 Upper Phy Accelerator. + +- L2 Processing** and **Timing** are connected to the **L1 Upper Phy Accelerator** via **nFAPI on Ethernet** and **PPS 10 MHz** respectively. +- The **L1 Upper Phy Accelerator** is connected to the external network via **O-RAN 7-2x**, **eCPRI FH QSFP28**, **200 Gbps+ Ethernet**, and **SyncE**. + +Figure 2.2.2-4 Accelerator Design 3 using Ethernet + +Figure 2.2.2-4 Accelerator Design 3 using Ethernet + +## 2.2.3 Synchronization and Timing + +In this reference design the DU has a GNSS receiver integrated on the network interface card. The GNSS receiver is connected via SMA cable to an external GNSS antenna. + +The PTP and SyncE signals are transported by Ethernet L2 via the fronthaul network interfaces to the O-RU. Together these provide the local time of day and frequency reference for the O-RU. + +Summary of timing related software features supported: + +- PTP distribution compliant to G.8272 +- ITU-T specifications for SyncE: + - Definitions: ITU-T G.8260 + - Architecture: ITU-T G.8261 + - SSM transport channel and format: ITU-T G.8264 + - Clock specifications: ITU-T G.8262 (EEC) + - Functional model and SSM processing: ITU-T G.781 +- IEEE 1588 Telecom Grand Master (T-TGM) using G8275.1 profile. +- T-GM conversion to Telecom Boundary Clock (T-TBC) if GNSS signal is lost. +- Telecom Boundary Clock (T-TBC) per ITU-T G.8273.2. +- Min 4-hour holdover/drift of max 0.65 $\mu$ sec, temperature change of +5°C or -5°C after Holdover starts. +- Compliant with input and output jitter and wander requirements specified in ITU-T G.8262 (for EEC). +- Alternate BMCA specified in G.8275.1. + +## 2.2.4 External Interface Ports + +The following table shows the external ports or slots that the system provided. In addition to 2 onboard 10GbE ports, a Network Interface Card provides a total of 12 additional Ethernet ports; 4 x 25G and 8 x10G. In this configuration the system has 200Gbps of aggregated Ethernet bandwidth. + +**Table 2.2.4-1 External Port List** + +| Port Name | Feature Description | +|-------------|--------------------------------------| +| Ethernet | 1 x GbE BMC management port | +| | 2 x 10GbE Base-T Ethernet connectors | +| | 1 x QSFP28 (via Ethernet NIC) | +| | 1 x QSFP+ (via Ethernet NIC) | +| | 4 x SFP+ (via Ethernet NIC) | +| PCIe | 2 x PCIe 5.0 x16 FHFL slots | +| | 1 x PCIe 5.0 x 16 LP slot | +| USB | 2 x USB 3.0 ports | +| | 2 x USB 2.0 ports | +| VGA | VGA port | +| Serial Port | COM port via RJ45 | +| SMA | GNSS Antenna in | +| | 10Mhz out | +| | 1PPS out | + +## 1 2.2.5 O-DU Firmware + +2 BIOS and BMC firmware are needed in the system and shall be installed. + +## 3 2.2.6 Mechanical + +### 4 2.2.6.1 Mother Board + +5 The mechanical layout of the mother board is detailed in Figure 2.2.6-1 Mother Board Layout Diagram and +6 shows the location of major components and interface ports. + +7 + + + +## 2.2.6.2 Chassis + +The 1U rack mount chassis contains the layout of the power supply, SSD, and fans. The chassis dimensions and layout are detailed in Figure 2.2.6-2 Chassis Mechanical Diagram. + +![Figure 2.2.6-2 Chassis Mechanical Diagram: A 3D perspective view of a 1U rack mount chassis. The diagram shows the internal layout of components including a power supply, SSD, and fans. Dimensions are indicated: 437mm for the front width, 429mm for the rear width, and 43mm for the height. A callout shows a single fan component labeled 'Fan'.](477afbf9aff73ff7414cea96a6f7633f_img.jpg) + +Figure 2.2.6-2 Chassis Mechanical Diagram: A 3D perspective view of a 1U rack mount chassis. The diagram shows the internal layout of components including a power supply, SSD, and fans. Dimensions are indicated: 437mm for the front width, 429mm for the rear width, and 43mm for the height. A callout shows a single fan component labeled 'Fan'. + +**Figure 2.2.6-2 Chassis Mechanical Diagram** + +## 2.2.6.3 Cooling + +The system is supplied with 6 x 40x56mm PWM fans for cooling. + +## 2.2.7 Power Unit + +In a fully loaded system with three PCIe slots populated, the system power consumption should be less than 400W. The total system power shall be kept at less than 80% of the power supply capacity. + +### 2.2.7.1 Power Supply + +The power is provided by dual redundant 600W DC 48V High-Efficiency power supplies w/PMBus 1.2. The power support input and output power rails are listed below. + +**Table 2.2.7-1 O-DU Power Requirements** + +| Supply Domain | Requirements | +|---------------|------------------| +| DC Input | -40Vdc to -65Vdc | +| DC Output | +5Vsb: 3A | +| | +12V: 50A | + +## 2.2.8 Thermal + +Active cooling with up to 6 fans is integrated in the chassis. + +The hardware acceleration cards described in Section 2.2.2.2 use passive cooling and a custom heatsink and are equipped with temperature sensors. It is designed to operate in temperatures ranging from -5°C to +55°C. + +## 2.2.9 Environmental and Regulations + +The O-DU hardware system is RoHS Compliant. The power supply unit is EMC FCC/CISPR Class B compliant. Table 2.2.9-1 lists the environmental related features and parameters. + +**Table 2.2.9-1 Environmental Features** + +| Item Name | Description | +|---------------------------------|----------------------------| +| Operating Temperature | -5°C to +55°C | +| Non-operating Temperature | -40°C to 70°C | +| Operating Relative Humidity | 8% to 90% (non-condensing) | +| Non-operating Relative Humidity | 5% to 95% (non-condensing) | + +The hardware accelerator described in Section 2.2.2.2 is designed to operate in indoor environments and in temperatures ranging from -5°C to +55°C. + +## 2.3 O- RU Hardware Reference Design + +This chapter defines the hardware reference design for the Outdoor Macrocell O-RU. This is defined by a 7-2 interface to the O-DU on one side and up to 64T64R on the antenna port (more details on the mMIMO O-RU<sub>7-2x</sub> reference designs are given in Section 2.5). No upper limit is defined to the output power of Wide Range BS according to 3GPP TS38.104-Section 6.2 [3], the external power is supplied by either AC or a standard DC -48V telecom source. + +## 2.3.1 O- RU High-Level Functional Block Diagram + +Figure 2.3.1-1 provides a high-level functional block diagram depicting the major HW/SW components. It also highlights the internal/external interfaces that are required. This document shows how to implement the system defined by the OMAC-HAR [6] document, and mMIMO O-RU<sub>7-2x</sub>, which can be realized with different high level radio architecture based on various functional splits and interface/interconnects between these functional blocks. + +![Figure 2.3.1-1 O-RU High-Level Functional Block Diagram](1bf5982d8291fa0f503910b7b52ada6e_img.jpg) + +The diagram illustrates the high-level functional block architecture of an O-RU<sub>7-2</sub>. The main processing chain is enclosed in a dashed box labeled 'O-RU<sub>7-2</sub>'. It consists of four primary functional blocks connected in series: the O-RAN FH Processing Unit, the Digital Processing Unit, the RF Processing Unit, and the Timing Unit. The O-RAN FH Processing Unit interfaces with the 'To/From O-DU<sub>7-2</sub> FH Interface'. The Digital Processing Unit and RF Processing Unit are connected to the Timing Unit. The Timing Unit is also connected to a 'Power Unit' located below it. A 'GNSS (optional)' block is shown to the left, providing 'Local timing from GNSS or equivalent' to the Timing Unit. The Timing Unit also receives 'Local timing from CDR' and provides timing to the O-RAN FH Processing Unit, Digital Processing Unit, and RF Processing Unit. The RF Processing Unit connects to the 'To/From Antenna'. + +Figure 2.3.1-1 O-RU High-Level Functional Block Diagram + +**Figure 2.3.1-1 O-RU High-Level Functional Block Diagram** + +## 2.3.2 O-RU Hardware Components + +Figure 2.3.2-1 shows the high-level block details of O-RU Hardware implementation example. The description of each block from left to right is given below. + +O-RU<sub>7-2x</sub> communicates with O-DU<sub>7-2x</sub> through O-RAN Fronthaul interface and the control/data packets are processed by O-RAN Fronthaul unit with the help of CUS plane processing block. Subsequently the packets are processed by Low-PHY functional blocks such as encoding, scrambling, modulation, layer mapping, precoding, beamforming, and resource element mapping in downlink. The reverse operation is done during the uplink process. The output of the Low-PHY block is fed to digital processing unit through packet interface. Here the frequency conversion in digital domain i.e., digital up conversion (DUC) in DL and digital down conversion (DDC) in UL are done. Furthermore, DPD and CFR algorithms are implemented in digital processing unit to enhance the power amplifier efficiency by reducing the PAPR/ACLR in RF front end. The output of digital processing unit is fed to RF processing unit through digital interface. The digital signals + +converted to analog in DL and vice versa in UL with the help of DAC and ADC functional blocks in Transceiver unit, respectively. Signals are further amplified with the help of functional blocks like PA in DL and LNA in UL in analog RF front end unit. The output of the amplifier is fed to a cavity filter to suppress the unwanted signals in DL and is done before amplification in the case of UL operation i.e., receive operation. The TDD switch is used to switch the operation between DL and UL, i.e., transmit and receive operations. The output of the cavity filter i.e., the O-RU is fed to antenna unit and then transmitted over the air. Three processing units such as FH, Digital, and RF powered up using the power unit and gets synchronized with the help of timing/synchronization block. In the case of beamforming scenario, antenna calibration is implemented using antenna calibration processing block. This coordinates with Low-PHY processing unit and calibration switch (Cal switch) and processes the signals coming from and going to the antenna calibration port, to compensate for the amplitude and phase offsets existing in each RF chain. Other implementations are also possible by rearranging the functional blocks of O-RAN FH, Digital processing, and RF processing units. + +![Figure 2.3.2-1 O-RU Architecture Example Implementation 1. This block diagram shows the internal structure of an O-RU7.2x. It is divided into three main processing units: O-RAN Fronthaul Processing Unit, Digital Processing Unit, and RF Processing Unit. The Fronthaul unit contains eCPRI C-Plane, S-Plane, and M-Plane Processing, and Low-PHY Processing. The Digital unit contains DDC, DUC, DPD, and CFR blocks. The RF unit contains a Transceiver (DAC and ADC), PA+LNA & TDD Switch, TDD Switch, Cavity Filter, and Filter. A Timing/Sync. Unit and a Power Unit are shared across the system. An Antenna Calibration Port connects the RF unit to an external Antenna array. Various interfaces like Packet Interface and Digital Interface connect the units. An O-RAN FH interface is shown on the left.](b7f36e332fb78c1d62f91399015a492c_img.jpg) + +Figure 2.3.2-1 O-RU Architecture Example Implementation 1. This block diagram shows the internal structure of an O-RU7.2x. It is divided into three main processing units: O-RAN Fronthaul Processing Unit, Digital Processing Unit, and RF Processing Unit. The Fronthaul unit contains eCPRI C-Plane, S-Plane, and M-Plane Processing, and Low-PHY Processing. The Digital unit contains DDC, DUC, DPD, and CFR blocks. The RF unit contains a Transceiver (DAC and ADC), PA+LNA & TDD Switch, TDD Switch, Cavity Filter, and Filter. A Timing/Sync. Unit and a Power Unit are shared across the system. An Antenna Calibration Port connects the RF unit to an external Antenna array. Various interfaces like Packet Interface and Digital Interface connect the units. An O-RAN FH interface is shown on the left. + +Figure 2.3.2-1 O-RU Architecture Example Implementation 1 + +![Figure 2.3.2-2 4T4R General Block Diagram with full RF front end. The diagram shows a system architecture for a 4T4R O-RU. On the left, a Digital Processing Unit (DPU) is connected to a Clock, Synchronizer, and Power Unit. The DPU has 'To O-DU' and 'SERDES' interfaces. It connects to a Transceiver block via 'SPI', 'Cal Control', and 'Clean Clock' lines. The Transceiver block contains four parallel transceiver channels (Tx0, Rx0, Tx1, Rx1, Tx2, Rx2, Tx3, Rx3) and a 'Cal Switch Box *'. Each channel has a 'bypass' and 'enable' control. The Transceiver connects to an RF Processing Unit, which contains four parallel RF chains (RFX0, RFX1, RFX2, RFX3). Each RF chain has a 'bypass', 'RF FE', 'PA', and 'enable' control. The RF Processing Unit connects to 'Port A' and a 'Cal Port'. A note at the bottom states: '*Calibration transceiver can be a separate unit or one of the main transceiver channels. Not all O-RUs will require antenna calibration.'](2d143272f6b2c1c94ba672d536283a66_img.jpg) + +Figure 2.3.2-2 4T4R General Block Diagram with full RF front end. The diagram shows a system architecture for a 4T4R O-RU. On the left, a Digital Processing Unit (DPU) is connected to a Clock, Synchronizer, and Power Unit. The DPU has 'To O-DU' and 'SERDES' interfaces. It connects to a Transceiver block via 'SPI', 'Cal Control', and 'Clean Clock' lines. The Transceiver block contains four parallel transceiver channels (Tx0, Rx0, Tx1, Rx1, Tx2, Rx2, Tx3, Rx3) and a 'Cal Switch Box \*'. Each channel has a 'bypass' and 'enable' control. The Transceiver connects to an RF Processing Unit, which contains four parallel RF chains (RFX0, RFX1, RFX2, RFX3). Each RF chain has a 'bypass', 'RF FE', 'PA', and 'enable' control. The RF Processing Unit connects to 'Port A' and a 'Cal Port'. A note at the bottom states: '\*Calibration transceiver can be a separate unit or one of the main transceiver channels. Not all O-RUs will require antenna calibration.' + +**Figure 2.3.2-2 4T4R General Block Diagram with full RF front end** + +Figure 2.3.2-2 and Figure 2.3.2-3 shows an example of an O-RU design for 4T4R and 8T8R, respectively. In subsequent sub-sections, we present detailed hardware components the O-RAN Processing Unit and Digital Processing Unit, RF processing unit, Power unit and Clock/Synchronization units. + +![Figure 2.3.2-3 8T8R General Block Diagram with RF front end. This block diagram illustrates the architecture of an 8T8R (8 Transmit, 8 Receive) transceiver. On the left, a 'Digital Processing Unit' (DPU) is connected to a 'Clock' and a 'Synchronizer'. The DPU has 'Rx enable' and 'Tx enable' inputs and outputs. It is connected to a 'Transceiver' block via 'SERIES' and 'SPI Cal Control' lines. The 'Transceiver' block contains eight parallel transceiver channels, each with its own 'Rx' and 'Tx' paths. Each channel includes a 'bypass' switch, an 'RFFE' (Radio Frequency Front End) block, and a 'PA' (Power Amplifier) block. The 'RFFE' and 'PA' blocks are controlled by 'enable' signals. The 'Transceiver' block is connected to an 'RF Processing Unit' on the right. The 'RF Processing Unit' has eight 'Port A' outputs, each connected to an antenna. A 'Cal Switch Box*' is connected to the 'Tx7' path of the transceiver. A 'Cal Port' is connected to the 'Cal Switch Box*'. A 'Power Unit' is connected to the 'Transceiver' block. A note at the bottom states: '*Calibration transceiver can be a separate unit or one of the main transceiver channels. Not all O-RUs will require antenna calibration.'](b842eb51a146fd3de7f69a858c97d041_img.jpg) + +To O-DU + +Digital Processing Unit + +Rx enable + +Tx enable + +SERIES + +SPI Cal Control + +Clock + +Network Clock + +SPI + +Clean Clock + +Synchronizer + +Power Unit + +Transceiver + +Rx0 + +Tx0 + +ORx0 + +ORx1 + +Tx1 + +Rx1 + +ORx2 + +Tx2 + +Rx2 + +ORx3 + +Tx3 + +Rx3 + +Rx4 + +Tx4 + +ORx4 + +ORx5 + +Tx5 + +Rx5 + +ORx6 + +Tx6 + +Rx6 + +ORx7 + +Tx7 + +Rx7 + +Cal Switch Box\* + +RF Processing Unit + +Port A + +Cal Port + +\*Calibration transceiver can be a separate unit or one of the main transceiver channels. +Not all O-RUs will require antenna calibration. + +Figure 2.3.2-3 8T8R General Block Diagram with RF front end. This block diagram illustrates the architecture of an 8T8R (8 Transmit, 8 Receive) transceiver. On the left, a 'Digital Processing Unit' (DPU) is connected to a 'Clock' and a 'Synchronizer'. The DPU has 'Rx enable' and 'Tx enable' inputs and outputs. It is connected to a 'Transceiver' block via 'SERIES' and 'SPI Cal Control' lines. The 'Transceiver' block contains eight parallel transceiver channels, each with its own 'Rx' and 'Tx' paths. Each channel includes a 'bypass' switch, an 'RFFE' (Radio Frequency Front End) block, and a 'PA' (Power Amplifier) block. The 'RFFE' and 'PA' blocks are controlled by 'enable' signals. The 'Transceiver' block is connected to an 'RF Processing Unit' on the right. The 'RF Processing Unit' has eight 'Port A' outputs, each connected to an antenna. A 'Cal Switch Box\*' is connected to the 'Tx7' path of the transceiver. A 'Cal Port' is connected to the 'Cal Switch Box\*'. A 'Power Unit' is connected to the 'Transceiver' block. A note at the bottom states: '\*Calibration transceiver can be a separate unit or one of the main transceiver channels. Not all O-RUs will require antenna calibration.' + +Figure 2.3.2-3 8T8R General Block Diagram with RF front end + +### 2.3.2.1 O-RAN Processing Unit + +The O-RAN Processing Unit (OPU) receives eCPRI frames from the O-RAN fronthaul and performs the fronthaul interface, lower L1, synchronization and beamforming. + +### 2.3.2.2 Digital Processing Unit + +The Digital Processing Unit (DPU) of the O-RU performs synchronization, DDC, DUC, CFR, and DPD. The DPU can be implemented as a FPGA or ASIC. + +The following block diagrams describe the digital processing unit as per example implementation in Figure 2.3.2-4 and Figure 2.3.2-5. + +Other implementations are possible. + +![Figure 2.3.2-4 Digital Processing Unit Block Diagram (L1 Processing + Beamforming)](29e01a7845f4656d99a2bb50629b7e8f_img.jpg) + +This block diagram illustrates the architecture of a Digital Processing Unit (DPU) for L1 processing and beamforming. A central block labeled 'CPU' is connected to 'Boot Flash', 'DDR', and 'OAM' on the left. Below the CPU is a large block labeled 'FPGA/ASIC'. To the right of the CPU, a dashed box contains 'L1 Proc. + Beamforming'. This dashed box is connected to 'DFE' (Digital Front-End) via an 'eCPRI/CPRI' interface. Below the dashed box, the 'FPGA/ASIC' block is connected to 'Clock & Sync' and 'Antenna Calibration' via 'Data & Control' interfaces. On the far left, 'SFP/QSFP' is connected to the 'FPGA/ASIC' block via a '10/25Gbps' interface. + +Figure 2.3.2-4 Digital Processing Unit Block Diagram (L1 Processing + Beamforming) + +Figure 2.3.2-4 Digital Processing Unit Block Diagram (L1 Processing + Beamforming) + +![Figure 2.3.2-5 Digital Processing Unit Block Diagram (DFE)](b139ce0bd8dcfdf5f29bb4b507489384_img.jpg) + +This block diagram illustrates an alternative architecture for a Digital Processing Unit (DPU) focusing on the Digital Front-End (DFE). A central block labeled 'CPU' is connected to 'Boot Flash', 'DDR', and 'OAM' on the left. Below the CPU is a large block labeled 'FPGA/ASIC'. To the right of the CPU, a dashed box contains 'DFE'. This dashed box is connected to 'RFIC' (Radio Frequency Integrated Circuit) via a 'JESD204B/C' interface. Below the dashed box, the 'FPGA/ASIC' block is connected to 'Clock & Sync' via a 'Clock & Control' interface. On the far left, 'Digital Processing' is connected to the 'FPGA/ASIC' block via an 'eCPRI/CPRI' interface. + +Figure 2.3.2-5 Digital Processing Unit Block Diagram (DFE) + +Figure 2.3.2-5 Digital Processing Unit Block Diagram (DFE) + +### 2.3.2.2.1 FPGA/ASIC Solution + +This solution for the digital processing unit is based on an FPGA with embedded ARM processor. + +#### 2.3.2.2.1.1 FPGA Requirements + +Table 2.3.2-1 shows the general interfaces required for an FPGA based design based on Figure 2.3.2-4 and Figure 2.3.2-5. + +**Table 2.3.2-1 FPGA Interface Requirements** + +| Item Name | Description | +|--------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| eCPRI Port | High speed bi-directional interface transporting data and control information. Total payload will be determined by the antennas/layers served, bandwidth supported, bit precision, subcarrier spacing, etc. It is typically served by one or more QSFP+ or SFP28 connectors depending on the payload. | +| SERDES | Up to 16 high speed JESD204B/C serial interface lanes between FPGA fabric and transceiver depending on transceiver configuration selected. | +| Boot Clock | Clock for any uC or fabric functions required immediately at power on | +| Sysref | JESD204B/C synchronization signal | +| DevCLK | JESD204B/C device clock | +| ARM Clock | Clock for the ARM processor | +| Memory Clock | Memory clock | +| OAM Port | Control interface used for maintenance | +| DDR | Interface for external DDR memory | + +#### 2.3.2.2.1.2 FPGA Design + +Table 2.3.2-2 shows the general blocks required for the design. The core elements implemented in this design are required to be sized to support the requirements shown in the OMAC-HAR [6] document. Specifically, the DPU should support up to 200 MHz of occupied BW with up to two 100 MHz component carriers. In addition to signal processing, the DPU should support C, U, S and M plane handling. Major processing blocks in the DPU are shown in Table 2.3.2-2. + +**Table 2.3.2-2 FPGA Functional Blocks** + +| Item Name | Description | Cat A | Cat B | +|-----------------|-----------------------------------------------------------------|----------|----------| +| FFT & CP- | FFT and Cyclic Prefix removal for uplink processing | Required | Required | +| iFFT & CP+ | iFFT and Cyclic Prefix insertion for downlink processing | Required | Required | +| PRACH Front End | PRACH front end processor | Required | Required | +| Channel DDC | Component Carrier Digital Down Converter | Optional | Optional | +| Channel DUC | Component Carrier Digital Up Converter | Optional | Optional | +| CFR | Crest Factor Reduction | Optional | Optional | +| DPD | Digital Pre-Distortion | Optional | Optional | +| JESD204B/C | JEDEC High speed serial interface type B or C framer/de-framer | Required | Required | +| C/U/M Plane | Control, User, and management Plane processing | Required | Required | +| 1588v2 Stack | IEEE 1588v2 Synchronization Software Stack | Required | Required | +| eCPRI | evolved Common Public Radio Interface framer/de-framer | Required | Required | +| I/Q Compression | I/Q compression/decompression for fronthaul lane rate reduction | Optional | Optional | +| Beamforming | Create & steer several beams | Optional | Optional | +| Pre-coding | Pre-coding | Optional | Required | +| RE Mapping | Resource Element Mapping to Antenna port | Optional | Required | + +### 2.3.2.3 RF Processing Unit + +The RF Processing Unit of O-RU includes the transceiver block, up/down converters, power amplifiers (PAs), low noise amplifiers (LNAs), Tx/Rx filters. All conversions between analog and digital domain (e.g., (RF sampling, frequency conversion using mixing of RF, IF and LO in up and down conversion) are performed within the transceiver block. Note that physical and logical partitioning within the RF processing unit need not occur at any specific boundary. + +#### 2.3.2.3.1 Transceiver Reference Design + +For the O-RU the sampling function and frequency conversion function is performed by transceiver. The purpose of the transceiver is to translate the RF signal to digital as early as possible in the signal chain and to reduce the data rate as low as possible to save power. The Transceiver is to convert between high-speed baseband data and a low-level RF for both transmit and receive signal chain. The transceiver may be responsible for orchestration of external gain control elements in both the receive and transmit paths. Other radio functions may need to be controlled by the DPU where they need to be controlled fast and synchronized with the TDD frame structure. Such elements include the transmit / receive switch, PA and LNA enable. + +##### 2.3.2.3.1.1 Hardware Specifications + +##### 2.3.2.3.1.1.1 Interface + +The following table shows the detail of the RF Processing Unit Interface Specifications: + +**Table 2.3.2-3 RF Processing Unit Interface Specifications** + +| Item Name | Description | +|------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| High Speed Data (SERDES Out, SERDES In) | High speed data represents the time-domain baseband information being transmitted or received. Depending on the configuration of the O-RAN device, various bandwidths may be supported leading to a range of payload rates. Options for data include JESD204B and JESD204C, or proprietary formats. Several options are shown in the following table. All data represents IQ 16-bit (N=16) precision. Some devices support IQ 12 bit (N'=12) which may reduce the required data rates accordingly. | +| Reference Clock (REF Clock In) | The transceiver should receive a reference for internal clock and LO synthesis needs. This reference clock can function as the JESD204 Device Clock where the interface is by SERDES. The specific clock frequency is determined by the operation mode of the transceiver. | +| Control | Provides the control functionalities of the transceiver. As an example, SPI or I2C may be supported, or other proprietary solutions. | +| GPIO (GPIO 1 – GPIO #) | The transceiver may optionally include GPIO for controlling peripherals including but not limited to PAs, LNAs and other devices. These GPIOs should at a minimum support 1.8V outputs but the specifics will be determined by the connected devices. The GPIO should also support input from peripheral devices. Input should at a minimum support 1.8V logic with tolerance of 3.3V preferred. An example could be MIPI/ GRFC interfaces. | +| Tx Enable | The transceiver should provide an output to support enabling and disabling the external devices in the transmit chain such as a TxVGA (optional) and PA. This may be part of the GPIO pins. | +| Rx Enable | The transceiver should provide an output to support enabling and disabling the external devices in the transmit chain such as a RF Front End Module or LNA. This may be part of the GPIO pins. | +| LNA Bypass | The transceiver should provide an output to support bypassing the LNA appropriately in the condition of a large blocker if so required. This may be part of the GPIO pins. | +| RF Outputs (Tx1 – Tx4 or Tx8) | RF outputs including the main Tx signal should support 50 ohm or 100 ohms signalling. These outputs can be either single ended or differential. | +| RF Inputs (Rx1 – Rx4 or Rx8 and ORx1 – ORx4 or ORx8) | RF inputs including the main Rx and the Observation Rx (ORx) (for DPD) should support 50 ohm or 100 ohms signalling. These inputs can be either single ended or differential. The device should support at least 1 ORx. | + +**Table 2.3.2-4 JESD204B/C Serial Data Rates** + +| Bandwidth | JESD204B | JESD204C | JESD204B | JESD204C | +|-----------|----------|----------|----------|----------| +| | 4T4R | | 8T8R | | +| 20 | 4.9152 | 4.05504 | 9.8304 | 8.11008 | +| 50 | 9.8304 | 8.11008 | 19.6608 | 16.22016 | +| 100 | 19.6608 | 16.22016 | 39.3216 | 32.44032 | +| 200 | 39.3216 | 32.44032 | 78.6432 | 68.88064 | + +#### 2.3.2.3.1.1.2 Algorithm + +The transceiver is required to provide appropriate algorithms to sustain RF operation including but not limited to Rx AGC, Tx Power control, DPD and CFR. + +### 2.3.2.3.1.1.3 Device Configuration + +The transceiver should support either 4T4R or 8T8R. In addition, at least one ORx path should be provided to support DPD functionality. + +### 2.3.2.3.1.1.4 Power Dissipation + +Total dissipation of transceiver IC for TRx should be less than 6 W for 4T4R. + +### 2.3.2.3.1.1.5 RF Specifications + +**Table 2.3.2-5 Transceiver RF Specifications** + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Condition/Comment | +|----------------------------------------------------|--------|-----|--------|------|--------|--------------------------------------------------------------------------------------------------------------| +| Transmitters | | | | | | | +| Centre Frequency | | 650 | | 6000 | MHz | | +| Transmitter Synthesis Bandwidth | | | | 450 | MHz | | +| Transmitter Large Signal Bandwidth | | | | 200 | MHz | | +| Transmitter Attenuator Power Control Range | | 0 | | 32 | dB | Signal to noise ratio (SNR) maintained for attenuation between 0 and 20 dB | +| Transmitter Attenuation Power Control Resolution | | | 0.05 | | dB | 20 MHz LTE/NR at -12 dBFS | +| Adjacent Channel Leakage Ratio (ACLR) | | | -66 | | dB | 75 MHz $< f \leq 2800$ MHz | +| In Band Noise Floor | | | -154.5 | | dBm/Hz | 0 dB attenuation; in band noise falls 1 dB for each dB of attenuation for attenuation between 0 dB and 20 dB | +| Out of Band Noise Floor | | | -153 | | dBm/Hz | 600 MHz $< f \leq 3000$ MHz | +| Maximum Output Power | | | 6 | | dBm | 0 dB attenuation; $3 \times$ bandwidth/2 offset | +| Third Order Output Intermodulation Intercept Point | OIP3 | | 27 | | dBm | 600 MHz $< f \leq 3000$ MHz | +| Error Vector Magnitude (3GPP Test Signals) | EVM | | | | | | +| 1900 MHz LO | | | 0.6 | | % | 50 kHz RF PLL loop bandwidth | +| 3800 MHz LO | | | 0.53 | | % | 300 kHz RF PLL loop bandwidth | +| Observation Receivers | ORx | | | | | | + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Condition/Comment | +|---------------------------------------------------|-------------------|-----|-------|------|------|----------------------------------------------------------------------------------------------------------------------------------| +| Center Frequency | | 450 | | 6000 | MHz | | +| Gain Range | | | 30 | | dB | IIP3 improves dB for dB for the first 18 dB of gain attenuation; QEC performance optimized for 0 dB to 6 dB of attenuation only. | +| Analog Gain Step | | | 0.5 | | dB | For attenuation steps from 0 dB to 6 dB | +| Receiver Bandwidth | | | | 450 | MHz | | +| Maximum Usable Input Level | P <sub>HIGH</sub> | | -11 | | dBm | 0 dB attenuation; increases dB for dB with attenuation. | +| Integrated Noise | | | -58.7 | | dBFS | 450 MHz Integration bandwidth | +| | | | -57.5 | | dBFS | 491.52 MHz Integration bandwidth | +| Third Order Input Intermodulation Intercept Point | IIP3 | | | | | | +| Narrow Band | | | | | | Maximum observation receiver gain; test condition: P <sub>HIGH</sub> -11 dB/tone | +| 1900 MHz | | | 15 | | dBm | | +| 2600 MHz | | | 16.5 | | dBm | | +| 3800 MHz | | | 18 | | dBm | | +| Wide Band | | | | | | IM3 products>130 MHz at baseband; test condition: P <sub>HIGH</sub> - 11 dB/tone; 491.52 MSPS | +| 1900 MHz | | | 13 | | dBm | | +| 2600 MHz | | | 11 | | dBm | | +| 3800 MHz | | | 13 | | dBm | | +| Third Order Intermodulation Product | IM3 | | -70 | | dBc | 600 MHz < f ≤ 3000 MHz | +| Spurious Free Dynamic Range | SFDR | | 64 | | dB | Non IMx related spurs, does not include HDx; (P <sub>HIGH</sub> - 11) dB input signal | +| Harmonic Distortion | | | | | | (P <sub>HIGH</sub> - 11) dB input signal | +| Second Order Harmonic Distortion Product | HD2 | | -80 | | dBc | In band HD falls within ±100 MHz | +| | | | -73 | | dBc | Out of band HD falls within ±225 MHz | +| Third Order Harmonic Distortion Product | HD3 | | -70 | | dBc | In band HD falls within ±100 MHz | +| | | | -65 | | dBc | Out of band HD falls within ±225 MHz | +| Receivers | | | | | | | + +| Parameter | Symbol | Min | Typ | Max | Unit | Test Condition/Comment | +|-----------------------------------|-------------------|-----|-----|------|------|----------------------------------------------------------------------------------------------------------------------------------------| +| Center Frequency | | | | 6000 | MHz | | +| Analog Gain Step | | | 30 | | dB | Attenuator steps from 0 dB to 6 dB | +| | | | 1 | | dB | Attenuator steps from 6 dB to 30 dB | +| Receiver bandwidth | | | | 200 | MHz | | +| Maximum Usable Input Level | P <sub>HIGH</sub> | | -11 | | dBm | 0 dB attenuation; increase dB for dB with attenuation; continuous wave = 1800 MHz; corresponds to -1 dBFS at ADC 75 MHz < f ≤ 3000 MHz | +| Noise Figure | NF | | 12 | | dB | 0 dB attenuation at receiver port 600 MHz < f ≤ 3000 MHz | +| Input Third Order Intercept Point | IIP3 | | | | | | +| Difference Product | IIP3, d | | | | | Two (P <sub>HIGH</sub> - 9) dB tones near band edge | +| 2600 MHz (Wideband) | | | 17 | | dBm | | +| 2600 MHz (Midband) | | | 21 | | dBm | | +| Sum Product | IIP3, s | | | | | Two (P <sub>HIGH</sub> - 9) dB tones, at bandwidth/6 offset from the LO | +| 2600 MHz (Wideband) | | | 20 | | dBm | | +| HD3 | HD3 | | -66 | | dBc | (P <sub>HIGH</sub> - 6) dB continuous wave tone at bandwidth/6 offset from the LO 600 MHz < f ≤ 4800 MHz | + +### 2.3.2.3.1.2 Hardware Design + +For the O-RU the sampling function and frequency conversion function can be performed by the transceiver. The transceiver integrates the ADC, DAC, LO, down converter, up converter, and related functions. The block diagram of transceiver design is shown in Figure 2.3.2-6. + +![Figure 2.3.2-6: Transceiver with Integrated CFR and DPD. This block diagram illustrates the internal architecture of a transceiver. At the top left, 'Clock, Synchronization & Synthesis' receives 'REF Clock In', 'SYSREF', and 'Ext LO/Clock In'. To its right are an 'SPI Port' and a 'Control Interface'. The SPI Port handles SCLK, CSB, SDO, and SDIO signals. The Control Interface manages CP101, GPIO2, GPIO3, and GPIO#. The main processing area is divided into three horizontal sections. The top section contains eight 'Receiver Block' units (labeled Rx8 to Rx1) and eight 'Transmit Block' units (labeled Tx8 to Tx1). Each Receiver Block includes an ADC and a block for 'Decimation, pFIR, AGC, Tuning, RSSI, Overload, Device Management'. Each Transmit Block includes a DAC and a block for 'Interpolation, pFIR, Tuning, Device Management'. The bottom section features an 'Observation Receiver' with eight inputs (ORx8 to ORx1) and an 'ADC', connected to a 'DPD Engine' and a block for 'Decimation, pFIR, AGC, Tuning, RSSI, Overload, Device Management'. On the far right, a 'Serial interface (JESD204B/C optional)' handles SYNC\ IN, SERDES Out, SERDES In, and SYNC\ OUT signals.](5168df759a16335758efba98247ff102_img.jpg) + +Figure 2.3.2-6: Transceiver with Integrated CFR and DPD. This block diagram illustrates the internal architecture of a transceiver. At the top left, 'Clock, Synchronization & Synthesis' receives 'REF Clock In', 'SYSREF', and 'Ext LO/Clock In'. To its right are an 'SPI Port' and a 'Control Interface'. The SPI Port handles SCLK, CSB, SDO, and SDIO signals. The Control Interface manages CP101, GPIO2, GPIO3, and GPIO#. The main processing area is divided into three horizontal sections. The top section contains eight 'Receiver Block' units (labeled Rx8 to Rx1) and eight 'Transmit Block' units (labeled Tx8 to Tx1). Each Receiver Block includes an ADC and a block for 'Decimation, pFIR, AGC, Tuning, RSSI, Overload, Device Management'. Each Transmit Block includes a DAC and a block for 'Interpolation, pFIR, Tuning, Device Management'. The bottom section features an 'Observation Receiver' with eight inputs (ORx8 to ORx1) and an 'ADC', connected to a 'DPD Engine' and a block for 'Decimation, pFIR, AGC, Tuning, RSSI, Overload, Device Management'. On the far right, a 'Serial interface (JESD204B/C optional)' handles SYNC\ IN, SERDES Out, SERDES In, and SYNC\ OUT signals. + +**Figure 2.3.2-6 Transceiver with Integrated CFR and DPD** + +### 2.3.2.4 Interface Requirements + +Table 2.3.2-6 shows the general interfaces required for the O-RAN Processing Unit and Digital Processing Unit based on Figure 2.3.2-4 and Figure 2.3.2-5. + +**Table 2.3.2-6 Interface Requirements** + +| Item Name | Description | +|---------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| eCPRI Port | High speed bi-directional interface transporting data and control information. Total payload will be determined by the antennas/layers served, bandwidth supported, bit precision, subcarrier spacing, etc. It is served by 4 SFP28 connectors. Actual number of SFP28 transceivers used will depend on RU configuration parameters (e.g., BFP compression bit-width, SRS configuration, etc). | +| SERDES | A number of serial interface lanes between DPU fabric and transceiver depending on transceiver configuration selected. For example, this could be a 16 lanes high speed JESD204B/C, or some other proprietary interface. | +| Boot Clock | Clock for any uC or fabric functions required immediately at power on | +| DDR | Interface for external DDR memory | +| System Clock | System clock | +| Clk / PPS out | SyncE / PTP terminated on the FPGA / ASIC | + +#### 2.3.2.4.1 O-RAN Processing Unit and DPU Design + +Table 2.3.2-25 shows the general blocks required for the design. The core elements implemented in this design are required to be sized to support the requirements shown in the OMAC-HAR [6] document. Specifically, the DPU should support up to 200 MHz of occupied BW with up to two 100 MHz component carriers. The OPU-DPU should be capable of processing at least 16 layers in the downlink and 8 layers in the uplink over the whole occupied BW for massive MIMO platforms. Non-massive MIMO platforms may support layers up to the number of antenna paths provided by the hardware. In addition to signal processing, the OPU-DPU should support C, U, S and M plane handling. Major processing blocks in the OPU-DPU are shown in Table 2.3.2-25. + +**Table 2.3.2-7 OPU-DPU Functional Blocks** + +| Item Name | Description | Cat A | Cat B | +|-----------------|------------------------------------------------------------------------------------------------------------------------|----------|----------| +| FFT & CP- | FFT and Cyclic Prefix removal for uplink processing | Required | Required | +| iFFT & CP+ | iFFT and Cyclic Prefix insertion for downlink processing | Required | Required | +| PRACH Front End | PRACH front end processor | Required | Required | +| Channel DDC | Component Carrier Digital Down Converter | Optional | Optional | +| Channel DUC | Component Carrier Digital Up Converter | Optional | Optional | +| CFR | Crest Factor Reduction | Optional | Optional | +| DPD | Digital Pre-Distortion | Optional | Optional | +| SERDES | High speed serial interface (can be JEDEC open interface or can be proprietary) | Required | Required | +| C/U/M Plane | Control, User, and management Plane processing | Required | Required | +| 1588v2 Stack | IEEE 1588v2 Synchronization Software Stack | Required | Required | +| eCPRI | evolved Common Public Radio Interface framer/de-framer | Required | Required | +| I/Q Compression | I/Q compression/decompression for fronthaul lane rate reduction, including Modulation Compression for Downlink in CatB | Required | Required | +| Beamforming | Create & steer several beams | Optional | Optional | +| Pre-coding | Pre-coding | Optional | Required | +| RE Mapping | Resource Element Mapping to Antenna port | Optional | Required | + +#### 2.3.2.4.2 Power Amplifier (PA) Reference Design + +##### 2.3.2.4.2.1 Hardware Specifications + +##### 2.3.2.4.2.1.1 Interface + +**Table 2.3.2-8 Power Amplifier Interface Specifications** + +| Item Name | Description | +|-----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| RF Enable | The enable input should be compatible with 1.8V logic and tolerate 3.3V as required. A logic high enables the PA. A logic low disables the device and places it in a minimum dissipation mode. | +| RF Output | RF outputs support 50-ohm single ended to properly interface to a directional coupler, isolator, switch, or antenna. | +| RF Input | RF inputs should support 50-ohm, single ended match to the transceiver output or preamp. | + +##### 2.3.2.4.2.1.2 Power Specifications + +RF output power required is nominally 10 W (40 dBm). For the whole Tx chain including pre-driver amplifier and driver Amplifier this Tx chain efficiency should be more than 33 % since driver and pre-driver work on less Power O/P and are less efficient. + +##### 2.3.2.4.2.1.3 RF Specifications + +The PA and driver should have enough gain to boost the transceiver output to the rated power level. The output power should be at least 10W (40 dBm) including the loss of the circulator and antenna filter. The ACLR with DPD and CFR should be better than 47dBc according to the related 3GPP test models. + +**Table 2.3.2-9 Power Amplifier RF Specifications** + +| Item Name | Band26 | Band66 | Band48 | +|--------------------|----------|----------|----------| +| Gain | 15 dB | 14.5 dB | 14 dB | +| P3dB | 50 dBm | 49.7 dBm | 49.8 dBm | +| Input Return Loss | < 12 dB | < 12 dB | < 12 dB | +| Output Return Loss | < 6 dB | < 6 dB | < 6 dB | +| Efficiency | > 42% | > 42% | > 45% | +| Band Flatness | < 0.4 dB | < 0.5 dB | < 0.6 dB | +| ACLR | <-28 dBc | <-28 dBc | <-29 dBc | + +#### 2.3.2.4.2.2 Hardware Design + +RFin is the input of the PA, RFout is the output of the PA. Vdd and Vbias is the power input of the PA. RFenable is the control pin to disable or enable the PA. The input and output should be matched to 50 ohms to optimize return loss as much as possible. Proper decoupling shall be provided to minimize the impact of supply ripple on the RF output. Figure 2.3.2-7 below details an example of a Power Amplifier reference design. + +![Figure 2.3.2-7 Power Amplifier Reference Design diagram. A central triangle represents the Power Amplifier (PA). The input is labeled RFin. The output is labeled RFout. The power supply is labeled Vdd. The bias supply is labeled Vbias. The enable pin is labeled RFen.](66b2e719a086d0042afe551bafd1084b_img.jpg) + +Figure 2.3.2-7 Power Amplifier Reference Design diagram. A central triangle represents the Power Amplifier (PA). The input is labeled RFin. The output is labeled RFout. The power supply is labeled Vdd. The bias supply is labeled Vbias. The enable pin is labeled RFen. + +**Figure 2.3.2-7 Power Amplifier Reference Design** + +#### 2.3.2.4.3 Low Noise Amplifier (LNA) Reference Design + +##### 2.3.2.4.3.1.1 Interface + +**Table 2.3.2-10 LNA Interfaces** + +| Item Name | Description | +|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Enable | The enable input should be compatible with 1.8V logic and tolerate 3.3V as required. A logic high enables the LNA. A logic low disables the device and places it in a minimum dissipation mode. | +| LNA Bypass | The LNA Bypass skips the second stage LNA effectively reducing the overall gain. This would be selected when the input signal compromises the linearity of the amplifier. | +| RF Out | RF outputs support 50-ohm single ended to properly interface to the RF filtering and Rx input port of transceiver. | +| TR Switch | The TR switch is used to shunt any reflected RF power that reaches the LNA to a shunt load during the transmit period. | +| RF Input | RF inputs should support 50-ohm, single ended match to circulator. | +| Termination | This RF output port shunts any reflected transmit power to an appropriate load during the Transmit period to protect the input of the LNA. | + +### 2.3.2.4.3.1.2 Power Specifications + +DC power per channel should not exceed 0.5W. + +### 2.3.2.4.3.1.3 RF Performance Specifications + +The following table shows the LNA RF specification for O-RU. + +**Table 2.3.2-11 LNA RF Specifications** + +| Item Name | Band 26 | Band 66 | Band 48 | +|------------------|------------|-------------|------------| +| Gain (High/Low) | 45/21 dB | 37/17 dB | 28/11 dB | +| NF (High/Low) | 0.7/0.7 dB | 0.5/0.5 dB | 1.1/1.1 dB | +| OIP3 (High/Low) | 35/33 dBm | 35/32 dBm | 36/30 dBm | +| OP1dB (High/Low) | 21/20 dBm | 20/17.5 dBm | 19/14dBm | +| TR Switch Time | na | na | 290 nsec | + +Considering RF output power required is nominally 10W (40 dBm). + +### 2.3.2.4.3.2 Hardware Design + +Figure 2.3.2-8 shows the configuration for a dual-stage LNA. The RF inputs and outputs should be properly matched to optimize the noise performance and flatness of the amplifier. The input switch is used to forward any reflected transmit energy to an external load during the transmit period to protect the LNA from damage. The DC supply voltage, VCC, should be properly filtered to prevent power supply noise from entering the LNA and reducing performance. + +![Figure 2.3.2-8 LNA Reference Design: A block diagram of a dual-stage LNA. The input RF_in is connected to a switch controlled by TR. The switch can route the signal to the LNA input or to a Termination_load. The LNA consists of two stages. The first stage is controlled by LNA_EN. The output of the first stage is connected to the input of the second stage. The second stage is controlled by LNA_bypass. The output of the second stage is RF_out. A VCC supply is connected to both stages.](72c85686d34c8c65b37b51b9a38f5c69_img.jpg) + +Figure 2.3.2-8 LNA Reference Design: A block diagram of a dual-stage LNA. The input RF\_in is connected to a switch controlled by TR. The switch can route the signal to the LNA input or to a Termination\_load. The LNA consists of two stages. The first stage is controlled by LNA\_EN. The output of the first stage is connected to the input of the second stage. The second stage is controlled by LNA\_bypass. The output of the second stage is RF\_out. A VCC supply is connected to both stages. + +**Figure 2.3.2-8 LNA Reference Design** + +### 2.3.2.4.4 Circulator Reference Design + +For TDD use, the Tx and Rx links work in time duplex. To properly couple the Tx energy to the antenna and the Rx signal to the LNA input, a circulator is used to perform this function given the potentially high RF power being processed through this device. The circulator can be configured as a clockwise or counterclockwise device depending on the layout details. + +### 2.3.2.4.4.1 Hardware Specifications + +#### 2.3.2.4.4.1.1 Interface + +The circulator includes 3 ports that can function as input or output. If the device is labelled clockwise, then for each input, its nominal output is the next pin rotating right around the device. If it is counterclockwise, the nominal output is the next pin rotating to the left around the device. + +#### 2.3.2.4.4.1.2 RF Specifications + +The following Table 2.3.2-12 details the Circulator Specifications for O-RU. + +**Table 2.3.2-12 Circulator Specifications** + +| Item Name | Band 26 | Band 66 | Band 48 | +|----------------|--------------------------|--------------------------|--------------------------| +| Rotation | Clockwise/Anti Clockwise | Clockwise/Anti Clockwise | Clockwise/Anti Clockwise | +| Average Power | 15 W | 15 W | 15 W | +| Peak Power | 90 W | 90 W | 90 W | +| Impedance | 50 $\Omega$ | 50 $\Omega$ | 50 $\Omega$ | +| Insertion Loss | $\leq 0.3$ dB | $\leq 0.3$ dB | $\leq 0.4$ dB | +| Isolation | $> 20$ dB | $> 20$ dB | $> 20$ dB | +| Return Loss | $> 20$ dB | $> 20$ dB | $> 20$ dB | + +#### 2.3.2.4.4.2 Hardware Design + +The example on the left in Figure 2.3.2-9 is a clockwise oriented device. The RF input enters pin 1 and exits pin 2. Pin 2 can also be used as an input and its output is pin 3. Finally pin 3 can also function as an input with pin 1 being the output. The device on the right is counterclockwise oriented and the signal flow is in the opposite direction. + +![Figure 2.3.2-9 shows two circular diagrams representing circulator reference designs. The left diagram shows a clockwise orientation with an arrow indicating the signal flow from pin 1 to pin 2, and then to pin 3. The right diagram shows a counterclockwise orientation with an arrow indicating the signal flow from pin 1 to pin 3, and then to pin 2.](b47d300e917e0fbc5c7fe8eb641c4011_img.jpg) + +Figure 2.3.2-9 shows two circular diagrams representing circulator reference designs. The left diagram shows a clockwise orientation with an arrow indicating the signal flow from pin 1 to pin 2, and then to pin 3. The right diagram shows a counterclockwise orientation with an arrow indicating the signal flow from pin 1 to pin 3, and then to pin 2. + +**Figure 2.3.2-9 Circulator Reference Design** + +#### 2.3.2.4.5 Antenna / Phased Array Reference Design + +The antenna is a transducer, and it is used to convert electrical signal to the Electromagnetic waves during the transmit mode and vice versa in the reception mode. Based on the radiation pattern characteristics of + +the antenna, it is broadly classified as omni-directional and directional antennas and examples of such antennas are listed below for reference. + +#### 2.3.2.4.5.1 Hardware Specifications for Omnidirectional Antenna + +The Table 2.3.2-13 below details the typical electrical omnidirectional antenna specifications for the O-RU. + +**Table 2.3.2-13 Omnidirectional Antenna Specifications** + +| Frequency band | n26 | n66/n70 | n48 | +|--------------------------------|-------------------|-------------------|-------------------| +| Antenna Type | Quasi-Omni | Quasi-Omni | Quasi-Omni | +| VSWR (max) | 1.5:1 | 1.5:1 | 1.5:1 | +| Power capacity | 75W per port, max | 75W per port, max | 35W per port, max | +| Gain (avg) | 5.0 dBi | 7.5 dBi | 6.0 dBi | +| Beam width (vertical) | 35° | 27° | 32° | +| Polarization | ±45° | ±45° | ±45° | +| 3rd Order PIM, @2x43 dBm | ≤-150 dBc | ≤-150 dBc | ≤-150 dBc | +| Isolation (cross polarization) | ≥25 dB | ≥25 dB | ≥25 dB | + +#### 2.3.2.4.5.2 Hardware Design of Omnidirectional Antenna + +One possible choice of the omnidirectional antenna is a canister type with multiple ports including the 4 ports for the 4T4R radio. Conceptual design is shown in the following figure. + +![A 3D perspective illustration of a canister-style omnidirectional antenna. It is a dark gray, vertically oriented cylinder with a rounded top. At the bottom circular face, there are four small, dark rectangular ports arranged in a square pattern, representing the 4T4R radio ports.](1ed472b32d40a9fa4ea1dd943a7c276b_img.jpg) + +A 3D perspective illustration of a canister-style omnidirectional antenna. It is a dark gray, vertically oriented cylinder with a rounded top. At the bottom circular face, there are four small, dark rectangular ports arranged in a square pattern, representing the 4T4R radio ports. + +**Figure 2.3.2-10 Canister Style Omni Antenna** + +### 2.3.2.4.5.3 Hardware Specifications for Directional Antenna + +The following table shows the typical electrical directional antenna specifications for the O-RU. + +**Table 2.3.2-14 Directional Antenna Specifications** + +| Frequency band | n71 | n26 | n66/n70 | +|--------------------------------|--------------------|--------------------|--------------------| +| Antenna Type | Directional 4T4R | Directional 4T4R | Directional 4T4R | +| VSWR (max) | 1.5:1 | 1.5:1 | 1.5:1 | +| Power capacity | 250W per port, max | 250W per port, max | 200W per port, max | +| Gain (avg) | 13.8 dBi | 14.5 dBi | 18.0 dBi | +| Beam width (horizontal) | 65° | 65° | 65° | +| Beam width (vertical) | 14° | 12° | 5° | +| Polarization | ±45° | ±45° | ±45° | +| Variable Down Tilt | 2-14 ° | 2-14 ° | 2-12 ° | +| 3rd Order PIM, @2x43 dBm | ≤-150 dBc | ≤-150 dBc | ≤-150 dBc | +| Isolation (cross polarization) | ≥25 dB | ≥25 dB | ≥25 dB | + +### 2.3.2.4.5.4 Hardware Design of Directional Antenna + +One possible choice of directional antennas are the radios mounted on the back of the antenna with 4 ports for the 4T4R radio on the back of the antenna just below each radio. Conceptual design is shown in the following figure. + +![Figure 2.3.2-11: Mounting Arrangement Scenario 1 of 4T4R Radios back of the Directional Antenna. The diagram shows a vertical antenna structure with two O-RU units mounted on the back. Each O-RU unit is connected to 4T4R RF connectivity ports. The diagram is a schematic representation of the hardware design.](7590c0aad657ef8cb87abf73d219002a_img.jpg) + +Figure 2.3.2-11: Mounting Arrangement Scenario 1 of 4T4R Radios back of the Directional Antenna. The diagram shows a vertical antenna structure with two O-RU units mounted on the back. Each O-RU unit is connected to 4T4R RF connectivity ports. The diagram is a schematic representation of the hardware design. + +**Figure 2.3.2-11 Mounting Arrangement Scenario 1 of 4T4R Radios back of the Directional Antenna** + +Another possible choice of directional antennas are the radios located away from the antenna with ports for each of the 4T4R radios on the bottom cap of the antenna. Conceptual design is shown in the following figure. + +![Figure 2.3.2-12: Mounting Arrangement Scenario 2 of 4T4R Radios back of the Directional Antenna. The diagram shows a tall, narrow antenna structure with a horizontal band of ports near the bottom. A label '4T4R RF connectivity' points to this band. Below the antenna, two dashed boxes labeled 'O-RU' are shown, each with a small rectangular connector at its base, indicating they connect to the antenna's ports.](b2908336394c9c44a79686a38b854aec_img.jpg) + +Figure 2.3.2-12: Mounting Arrangement Scenario 2 of 4T4R Radios back of the Directional Antenna. The diagram shows a tall, narrow antenna structure with a horizontal band of ports near the bottom. A label '4T4R RF connectivity' points to this band. Below the antenna, two dashed boxes labeled 'O-RU' are shown, each with a small rectangular connector at its base, indicating they connect to the antenna's ports. + +**Figure 2.3.2-12 Mounting Arrangement Scenario 2 of 4T4R Radios back of the Directional Antenna** + +### 2.3.2.5 Internal Interfaces + +The following sections describe potentially useful optional interfaces within the white box. These optional interfaces are not required and may be used at the discrepancy of the manufacturer. This section is provided strictly as information only to better clarify the functionality of these interfaces. + +#### 2.3.2.5.1 Optional JESD204 Interfacing + +O-RU solutions requiring chip to chip interfacing of high-speed time domain data may benefit from utilization of JEDEC defined standard JESD204 [12]. This interface is specified for chip-to-chip interfacing that provides fast, low latency and time aligned data. The benefit of such an interface is to enable an open standard that allows for devices from multiple vendors to seamlessly interface. From a logistical perspective JESD204 allows multiple devices to communicate over the same link in a multiplex fashion while preserving time alignment and providing deterministic latency. This makes JESD204 a good candidate interface for carrying the signals for multiple antennas, multiple component carriers including I and Q data. This allows for relative simplicity requiring only a few differential pairs along with a 'device clock' and 'sysref' signals to carry and synchronize all time aligned signals. + +Figure 2.3.2-13 provides an example of a typical configuration for a JESD204 configuration. The lines labelled 'JESD for UL x2' and 'JESD for DL x2' are the data bearing connections and consist of differential + +pairs. In this example, there are 2 differential pairs for the UL data (receiver path) and 2 differential pairs for the DL data (transmit path). These connections provide data using an embedded clock and synchronization with a transport layer coding used to ensure sufficient transitions that the embedded clock can be recovered on the receiving end. + +The second signal is labelled 'Device Clock'. The device clock provides the frequency reference to devices in the configuration. Within the scope of JESD204, this signal provides the reference for the interface. In practice, the Device Clock also provide the frequency reference to the individual devices and is usually a multiple of 30.72 MHz. JESD204 connected devices would use this reference for both the interface as well as other frequency services within the device such as sample clocks and other PLLs. + +The final signal is the 'Sysref' which enables deterministic latency in the system. Each interconnected device uses this signal in conjunction with 'Device Clock' to determine exactly when the sample edge should occur. There are different ways to configure and use 'Sysref' to achieve different goal. For more details on configuration, see [12]. + +JESD204 is an evolving standard. Although it has been around for a while, as process technology evolves and data needs grow, JESD has evolved to keep pace with throughput needs. The initial variation supported up to 3.125 Gbps. JESD204A brought speeds up to 6.25 Gbps. JESD204B brought throughput to 12.5 Gbps. Most recently JESD204C offers throughputs up to 32.45 Gbps. Each variety offers at least one option for transport layer coding like 8B/10B as well as a range of other features including sub-channel coding which allows control channels to be passed along with the primary data. Currently most devices support JESD204B and JESD204C. As of this writing, JEDEC is underway defining the next phase of JESD204x which will further increase data rates as demanded by increasing bandwidth in wireless and other application. + +**Table 2.3.2-15 JESD204 Abridged Lexicon** + +| Parameter | Description | +|------------|--------------------------------------------------| +| M | Number of converters/converter device (link) | +| NP (or N') | Total number of bits per sample | +| S | Samples transmitted/single converter/frame cycle | +| F | Octets/Frame | +| K | Number of frames per multi-frame | +| SC | Sample Clock Rate | +| L | Number of lanes/converter device (link) | + +To better comprehend the JESD204 standard, understanding the lexicon is important. There are many parameters that can be used, but those in Table 2.3.2-15 provide the core definitions. Most of these are basic parameters related to common data converter characteristics and include the number of converters, number of bits and sample rate. The remaining parameters are related to the transport layer and physical implementation of the interface. + +Combined, the parameters in this lexicon help define the data throughput, number of lanes required as well as the framing of data onto the interfaces. Starting with the payload, it is determined by computing the serial data rate and adding the transport layer (i.e. 8B/10B, 64B/66B etc) to that as defined in the following equation: + +$$M \times NP \times SC \times \text{Transport Layer Coding} = \text{Payload Rate}$$ + +This equation provides the total payload to be delivered between devices. This data is delivered over one or more lanes. If the payload exceeds the capacity of one lane, additional lanes are added to ensure that the throughput per lane matches the capability of the standard. As highlighted in preceding paragraphs, currently JESD204B supports up to 12.5 Gbps and JESD204C supports up to 32.45 Gbps but future evolutions will include higher lane capacity. Where the Payload Rate exceeds an individual lanes capacity, the total Payload Rate is divided by the lane capacity, currently 12.5 Gbps or 32.45 Gbps, to determine the approximate number of lanes required. The actual number is the next higher integer to ensure that the lane rate is less than the maximum specified or desired. As the standard continues to evolve, this same math will be used to determine the payload and number of lanes, L. + +$$L = \text{Celing} \left( \frac{\text{Payload Rate}}{\text{Max Lane Rate}} \right)$$ + +The final important term is F, the number of octets per frame. In JESD204, an octet represents an encoded 8-bit word. Fundamentally, F defines the frame structure given the number of lanes and the specific payload to deliver. F is defined by the following equation and represents the number of octets per frame: + +$$F = \frac{M \times X \times NP}{8 \times L}$$ + +Figure 2.3.2-13 provides an example 4T4R configuration supporting a typical 100 MHz waveform. The low PHY device processes complex (I & Q data) for each data path and thus there are a total of 8 data streams that must be moved between the digital chip and the data conversion. The bit precision of this data is sufficient to meet the noise requirements of the solution and could be 12 or more bits. For this example, 16-bits will be assumed. To support a 100 MHz bandwidth, a complex data rate of 122.88 MSPS will be used as indicated by Table 2.3.2-16 of [3]. + +![Figure 2.3.2-13 Example 4T4R JESD204 Configuration. The diagram shows a clock synthesis block connected to two device clocks, Device Clock A and Device Clock B. Device Clock A is connected to four ADCs and four DACs, both labeled JESD PHY. Device Clock B is connected to a block labeled DFE & Low PHY Or Low PHY. The clock synthesis block also provides Sysref A and Sysref B signals. JESD for UL x2 connects the ADCs to the DFE & Low PHY block. JESD for DL x2 connects the DFE & Low PHY block to the DACs. A 'To RFFE' label is on the left, and a 'Fronthaul' label is on the right.](7c8d96ce1db2a4c1c52df5f19f50cd68_img.jpg) + +Figure 2.3.2-13 Example 4T4R JESD204 Configuration. The diagram shows a clock synthesis block connected to two device clocks, Device Clock A and Device Clock B. Device Clock A is connected to four ADCs and four DACs, both labeled JESD PHY. Device Clock B is connected to a block labeled DFE & Low PHY Or Low PHY. The clock synthesis block also provides Sysref A and Sysref B signals. JESD for UL x2 connects the ADCs to the DFE & Low PHY block. JESD for DL x2 connects the DFE & Low PHY block to the DACs. A 'To RFFE' label is on the left, and a 'Fronthaul' label is on the right. + +**Figure 2.3.2-13 Example 4T4R JESD204 Configuration** + +Using this information and the equations above and applying 8B10B transport layer coding, the total payload, number of lanes and octets per frame can be computed. Since this is a 4T4R application and each path is represented by a complex stream, 'M' equals 8. 'NP' is 16 bits. 'SC' equals 122.88 MSPS. Total data payload can be computed using the following equation: + +$$Payload = 8 \times 16 \times 122.88 \times 10^6 \times \frac{10}{8} = 19.6608 Gbps$$ + +Assuming the interface is based on JESD204B, then the maximum data rate for a single lane would be 12.5 Gbps. Therefore, we need to divide the data into two physical lanes of 9.8304 Gbps each. Hence in this example, 'L' equals 2. + +$$L = Ceiling\left(\frac{19.6608 Gbps}{12.5 Gbps}\right) = 2$$ + +Finally, 'F' the number of Octets/Frame is computed to be 8. + +$$F = \frac{8 \times 1 \times 16}{8 \times 2} = 8$$ + +Using this information, the mapping of data can be determined by using online tools such as [13]. These tools describe how the converter data is mapped onto each lane by octet as shown in Figure 2.3.2-14. In this example on lane 0, the first octet conveyed are the most significant bits of converter 0. This is followed by the LSBs in the second octet. This is followed by converter 1, 2 and 3 on lane 0. In parallel, lane 1 provides the data for converters 5 through 7 with the most significant octet leading. In this figure, M#SO represents the logical converter where # identifies the specific converter. + +Table 2.3.2-16 4T4R Example Data Mapping + +| | 4 (L = 2, M = 8, F = 8, S = 1, NP = 16) | | | | | | | | +|-------|-----------------------------------------|-----------|------------|-----------|------------|-----------|------------|-----------| +| | Frame 0 | | | | | | | | +| Lanes | Octet 0 | Octet 1 | Octet 2 | Octet 3 | Octet 4 | Octet 5 | Octet 6 | Octet 7 | +| 0 | M0S0[15:8] | M0S0[7:0] | M1S0[15:8] | M1S0[7:0] | M2S0[15:8] | M2S0[7:0] | M3S0[15:8] | M3S0[7:0] | +| 1 | M4S0[15:8] | M4S0[7:0] | M5S0[15:8] | M5S0[7:0] | M6S0[15:8] | M6S0[7:0] | M7S0[15:8] | M7S0[7:0] | + +More complicated examples are also supported as shown in Figure 2.3.2-14 where a 64T64R massive MIMO application is described. This configuration supports a 200 MHz iBW and thus requires a complex data rate of 245.76 MSPS. In this case, there are 64 transmit and 64 receive paths. Each of these requires a complex path to the low PHY / beam former device. Therefore 'M' equals 128. Each of these are represented by 16 bits. In this example, JESD204C is assumed and thus 64B/66B coding is used. Thus, the total throughput becomes: + +$$Payload = 128 \times 16 \times 245.76 \times 10^6 \times \frac{66}{64} = 519.04512 Gbps$$ + +![Figure 2.3.2-14 Example 64T64R JESD204 Configuration. This block diagram illustrates the JESD204 configuration for a 64T64R system. At the top, 'Device Clock A' and 'Device Clock B' feed into a 'Clock Synthesis' block, which outputs 'Sysref A' and 'Sysref B'. On the left, two vertical blocks represent the transceivers, each containing 8 ADCs (top) and 8 DACs (bottom), labeled 'x8'. These are connected to 'JESD PHY' blocks. The top PHY is connected to 'JESD for UL x16' and 'JESD for DL x16'. The bottom PHY is connected to 'JESD for DL x16'. The 'JESD for UL x16' and 'JESD for DL x16' blocks are connected to a central 'DFE & Low PHY Or Low PHY' block. This block is connected to 'Fronthaul' on the right. A 'To RFFE' label is on the far left. Arrows indicate the flow of data and clock signals.](d1bd7a6d95b0f29930b2c64d2bc5e54e_img.jpg) + +Figure 2.3.2-14 Example 64T64R JESD204 Configuration. This block diagram illustrates the JESD204 configuration for a 64T64R system. At the top, 'Device Clock A' and 'Device Clock B' feed into a 'Clock Synthesis' block, which outputs 'Sysref A' and 'Sysref B'. On the left, two vertical blocks represent the transceivers, each containing 8 ADCs (top) and 8 DACs (bottom), labeled 'x8'. These are connected to 'JESD PHY' blocks. The top PHY is connected to 'JESD for UL x16' and 'JESD for DL x16'. The bottom PHY is connected to 'JESD for DL x16'. The 'JESD for UL x16' and 'JESD for DL x16' blocks are connected to a central 'DFE & Low PHY Or Low PHY' block. This block is connected to 'Fronthaul' on the right. A 'To RFFE' label is on the far left. Arrows indicate the flow of data and clock signals. + +**Figure 2.3.2-14 Example 64T64R JESD204 Configuration** + +JESD204C supports up to 32.45 Gbps and therefore 16 lanes will be required as shown below. In this example, each transceiver device supports 8 channels. Therefore, each radio requires 2 UL and 2 DL JESD lanes which represents a total of 16 lanes in each direction as computed. + +$$L = \text{Ceiling} \left( \frac{519.04512 \text{ Gbps}}{32.45 \text{ Gbps}} \right) = 16$$ + +Using the equation for 'F' determines the octets per frame to be 16 in this example. The frame structure as defined by JESD204 is shown in Figure 2.3.2-15. As with the previous example, the frame structure is little endian with lane 0 beginning with converter 0, lane 1 beginning with 8, lane 2 with 16 and so forth as shown. Complete details on JESD204 can be found [12]. + +$$F = \frac{128 \times 1 \times 16}{8 \times 16} = 16$$ + +| 64 (L = 16, M = 128, F = 16, S = 1, NP = 16) | | | | | | | | | | | | | | | | | +|----------------------------------------------|--------------|-------------|--------------|-------------|--------------|-------------|--------------|-------------|--------------|-------------|--------------|-------------|--------------|-------------|--------------|-------------| +| Frame 0 | | | | | | | | | | | | | | | | | +| Lanes | Octet 0 | Octet 1 | Octet 2 | Octet 3 | Octet 4 | Octet 5 | Octet 6 | Octet 7 | Octet 8 | Octet 9 | Octet 10 | Octet 11 | Octet 12 | Octet 13 | Octet 14 | Octet 15 | +| 0 | M050[15:8] | M050[7:0] | M150[15:8] | M150[7:0] | M250[15:8] | M250[7:0] | M350[15:8] | M350[7:0] | M450[15:8] | M450[7:0] | M550[15:8] | M550[7:0] | M650[15:8] | M650[7:0] | M750[15:8] | M750[7:0] | +| 1 | M850[15:8] | M850[7:0] | M950[15:8] | M950[7:0] | M1050[15:8] | M1050[7:0] | M1150[15:8] | M1150[7:0] | M1250[15:8] | M1250[7:0] | M1350[15:8] | M1350[7:0] | M1450[15:8] | M1450[7:0] | M1550[15:8] | M1550[7:0] | +| 2 | M1650[15:8] | M1650[7:0] | M1750[15:8] | M1750[7:0] | M1850[15:8] | M1850[7:0] | M1950[15:8] | M1950[7:0] | M2050[15:8] | M2050[7:0] | M2150[15:8] | M2150[7:0] | M2250[15:8] | M2250[7:0] | M2350[15:8] | M2350[7:0] | +| 3 | M2450[15:8] | M2450[7:0] | M2550[15:8] | M2550[7:0] | M2650[15:8] | M2650[7:0] | M2750[15:8] | M2750[7:0] | M2850[15:8] | M2850[7:0] | M2950[15:8] | M2950[7:0] | M3050[15:8] | M3050[7:0] | M3150[15:8] | M3150[7:0] | +| 4 | M3250[15:8] | M3250[7:0] | M3350[15:8] | M3350[7:0] | M3450[15:8] | M3450[7:0] | M3550[15:8] | M3550[7:0] | M3650[15:8] | M3650[7:0] | M3750[15:8] | M3750[7:0] | M3850[15:8] | M3850[7:0] | M3950[15:8] | M3950[7:0] | +| 5 | M4050[15:8] | M4050[7:0] | M4150[15:8] | M4150[7:0] | M4250[15:8] | M4250[7:0] | M4350[15:8] | M4350[7:0] | M4450[15:8] | M4450[7:0] | M4550[15:8] | M4550[7:0] | M4650[15:8] | M4650[7:0] | M4750[15:8] | M4750[7:0] | +| 6 | M4850[15:8] | M4850[7:0] | M4950[15:8] | M4950[7:0] | M5050[15:8] | M5050[7:0] | M5150[15:8] | M5150[7:0] | M5250[15:8] | M5250[7:0] | M5350[15:8] | M5350[7:0] | M5450[15:8] | M5450[7:0] | M5550[15:8] | M5550[7:0] | +| 7 | M5650[15:8] | M5650[7:0] | M5750[15:8] | M5750[7:0] | M5850[15:8] | M5850[7:0] | M5950[15:8] | M5950[7:0] | M6050[15:8] | M6050[7:0] | M6150[15:8] | M6150[7:0] | M6250[15:8] | M6250[7:0] | M6350[15:8] | M6350[7:0] | +| 8 | M6450[15:8] | M6450[7:0] | M6550[15:8] | M6550[7:0] | M6650[15:8] | M6650[7:0] | M6750[15:8] | M6750[7:0] | M6850[15:8] | M6850[7:0] | M6950[15:8] | M6950[7:0] | M7050[15:8] | M7050[7:0] | M7150[15:8] | M7150[7:0] | +| 9 | M7250[15:8] | M7250[7:0] | M7350[15:8] | M7350[7:0] | M7450[15:8] | M7450[7:0] | M7550[15:8] | M7550[7:0] | M7650[15:8] | M7650[7:0] | M7750[15:8] | M7750[7:0] | M7850[15:8] | M7850[7:0] | M7950[15:8] | M7950[7:0] | +| 10 | M8050[15:8] | M8050[7:0] | M8150[15:8] | M8150[7:0] | M8250[15:8] | M8250[7:0] | M8350[15:8] | M8350[7:0] | M8450[15:8] | M8450[7:0] | M8550[15:8] | M8550[7:0] | M8650[15:8] | M8650[7:0] | M8750[15:8] | M8750[7:0] | +| 11 | M8850[15:8] | M8850[7:0] | M8950[15:8] | M8950[7:0] | M9050[15:8] | M9050[7:0] | M9150[15:8] | M9150[7:0] | M9250[15:8] | M9250[7:0] | M9350[15:8] | M9350[7:0] | M9450[15:8] | M9450[7:0] | M9550[15:8] | M9550[7:0] | +| 12 | M9650[15:8] | M9650[7:0] | M9750[15:8] | M9750[7:0] | M9850[15:8] | M9850[7:0] | M9950[15:8] | M9950[7:0] | M10050[15:8] | M10050[7:0] | M10150[15:8] | M10150[7:0] | M10250[15:8] | M10250[7:0] | M10350[15:8] | M10350[7:0] | +| 13 | M10450[15:8] | M10450[7:0] | M10550[15:8] | M10550[7:0] | M10650[15:8] | M10650[7:0] | M10750[15:8] | M10750[7:0] | M10850[15:8] | M10850[7:0] | M10950[15:8] | M10950[7:0] | M11050[15:8] | M11050[7:0] | M11150[15:8] | M11150[7:0] | +| 14 | M11250[15:8] | M11250[7:0] | M11350[15:8] | M11350[7:0] | M11450[15:8] | M11450[7:0] | M11550[15:8] | M11550[7:0] | M11650[15:8] | M11650[7:0] | M11750[15:8] | M11750[7:0] | M11850[15:8] | M11850[7:0] | M11950[15:8] | M11950[7:0] | +| 15 | M12050[15:8] | M12050[7:0] | M12150[15:8] | M12150[7:0] | M12250[15:8] | M12250[7:0] | M12350[15:8] | M12350[7:0] | M12450[15:8] | M12450[7:0] | M12550[15:8] | M12550[7:0] | M12650[15:8] | M12650[7:0] | M12750[15:8] | M12750[7:0] | + +Figure 2.3.2-15 64T64R Example Data Mapping + +## 2.3.3 Synchronization and Timing + +The clock and synchronization are determined by the PTP and SyncE signals transported by ethernet L2 via the front haul in conjunction with clock recovery in the hardware. Together these provide the local time of day and frequency reference for the O-RU. + +![Figure 2.3.3-1 Clock and Synchronization Functional Block Diagram. The diagram shows a central 'Clock Software Stack' block. It receives inputs from 'Ethernet TRx' (labeled 'Ethernet Clock'), 'QSFP' (labeled 'Embedded CLK'), and 'GPS/Aux or Cascade' (labeled 'GPS/Aux Clock'). It outputs 'Control' to an 'RF TRx' block and 'Clock, Sync & Control' to a 'Synchronizer' block. The 'Synchronizer' block outputs 'DevCLK, Sysref' to the 'RF TRx' and is connected to a 'TCXO' block. A 'Clock Synthesizer' block receives 'Clock, Sync & Control' from the 'Clock Software Stack' and is connected to an 'XTAL' block.](56956e261504ecd291a7758cf7a5482b_img.jpg) + +Figure 2.3.3-1 Clock and Synchronization Functional Block Diagram. The diagram shows a central 'Clock Software Stack' block. It receives inputs from 'Ethernet TRx' (labeled 'Ethernet Clock'), 'QSFP' (labeled 'Embedded CLK'), and 'GPS/Aux or Cascade' (labeled 'GPS/Aux Clock'). It outputs 'Control' to an 'RF TRx' block and 'Clock, Sync & Control' to a 'Synchronizer' block. The 'Synchronizer' block outputs 'DevCLK, Sysref' to the 'RF TRx' and is connected to a 'TCXO' block. A 'Clock Synthesizer' block receives 'Clock, Sync & Control' from the 'Clock Software Stack' and is connected to an 'XTAL' block. + +**Figure 2.3.3-1 Clock and Synchronization Functional Block Diagram** + +### 2.3.3.1 Hardware Specifications + +#### 2.3.3.1.1 Interface + +**Table 2.3.3-1 Synchronization and Timing Interface Specifications** + +| Item Name | Description | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------| +| Clock Inputs | Depending on the configuration, the following clock inputs may exist: QFSP, Ethernet, GPS, Cascaded unit clocks, Synchronized Clock. | +| Clock Outputs | Depending on functional requirements, the following clocks may be delivered: QFSP, Ethernet, DDR, CPU, RF Transceiver clock, Synchronizer reference. | +| Clock Control | SPI or I2C to control the clock synthesizer and synchronizer. | +| Clock Sync | Logic signal to phase align and time align the synchronizer with master. | +| Crystal Reference | One or more reference oscillators to provide required phase noise and short/long term stability. | + +#### 2.3.3.1.2 Performance Specifications + +See device synchronizer performance specifications in Table 2.3.3-2 + +### 2.3.3.1.3 Synchronizer + +The purpose of the Synchronizer is to function as part of the local clock recovery in conjunction with an IEEE1588v2 software stack to provide local time of day and to generate a local synchronous reference signals to be used for synthesis of necessary clocks to other functions within the O-RU. + +#### 2.3.3.1.3.1 Hardware Specifications + +##### 2.3.3.1.3.1.1 Interface + +**Table 2.3.3-2 Synchronizer Interface Specifications** + +| Item Name | Description | +|---------------------------------------------|----------------------------------------------------------------------------| +| REFA, REFAA | differential or single ended reference pulse inputs. | +| REFB, REFBB | differential or single ended reference pulse inputs. | +| Status and Control | control core operation and report on state of the PLL. | +| XOA, XOB | complimentary reference inputs or reference crystal connections | +| Output0 and Output0N & Output1 and Output1N | reference outputs to feed further synthesis, transceiver, or logic blocks. | + +##### 2.3.3.1.3.1.2 Performance Specifications + +**Table 2.3.3-3 Synchronizer Performance Specifications** + +| Item Name | Description | Notes | +|----------------|-------------|-----------------------------------------------------------------------------------------------------------------------------------------------------| +| 10 Hz Offset | -77 dBc/Hz | Device configuration: fOSC = 52 MHz crystal, fREF = 30.72 MHz, fVCO = 2457.6 MHz, fOUT = 245.76 MHz, DPLL BW = 50 Hz, internal zero delay operation | +| 100 Hz Offset | -93 dBc/Hz | | +| 1 kHz Offset | -114 dBc/Hz | | +| 10 kHz Offset | -125 dBc/Hz | | +| 100 kHz Offset | -130 dBc/Hz | | +| 1 MHz Offset | -140 dBc/Hz | | +| 10 MHz Offset | -156 dBc/Hz | | + +### 2.3.3.1.3.2 Hardware Design + +![Figure 2.3.3-2 Synchronizer Block Diagram. This block diagram illustrates the internal architecture of a synchronizer. On the left, 'REFERENCE INPUTS' (REFA, REFAA, REFB, REFB) feed into a 'DIGITAL CROSS POINT MUX'. This mux is also connected to 'REFERENCE MONITORS', 'REFERENCE SWITCHING CONTROL', 'AUXILIARY NCOs', 'AUXILIARY TDCs', and 'STATUS AND CONTROL PINS'. The mux outputs to two PLL blocks, PLL0 and PLL1. Each PLL block contains a 'DPLL' (with NCO) and an 'APLL' (with VCO), followed by a '+2' multiplier and a '+Q' output stage. 'INTERNAL ZERO DELAY' lines connect the DPLL and APLL sections of each PLL. The PLL0 outputs are labeled 'DISTRIBUTION OUTPUTS' and include OUT0AP, OUT0AN, OUT0BP, OUT0BN, OUT0CP, and OUT0CN. The PLL1 outputs are labeled 'DISTRIBUTION OUTPUTS' and include OUT1AP, OUT1AN, OUT1BP, and OUT1BN. A 'SYSTEM CLOCK' is derived from the PLL outputs and passes through 'SYSTEM CLOCK PLL' and 'SYSTEM CLOCK COMPENSATION' (which is also connected to a 'TEMPERATURE SENSOR'). The 'SYSTEM CLOCK' is also connected to 'XOA' and 'XOB'. A 'SERIAL PORT (SPI/I2C) AND EEPROM CONTROLLER' is connected to the 'DIGITAL CROSS POINT MUX' and a 'SERIAL PORT'. The 'SERIAL PORT' is also connected to 'M0 TO M6' and an 'EEPROM (OPTIONAL)'.](f6db8899a4ac51e9f125bcff1d10a035_img.jpg) + +Figure 2.3.3-2 Synchronizer Block Diagram. This block diagram illustrates the internal architecture of a synchronizer. On the left, 'REFERENCE INPUTS' (REFA, REFAA, REFB, REFB) feed into a 'DIGITAL CROSS POINT MUX'. This mux is also connected to 'REFERENCE MONITORS', 'REFERENCE SWITCHING CONTROL', 'AUXILIARY NCOs', 'AUXILIARY TDCs', and 'STATUS AND CONTROL PINS'. The mux outputs to two PLL blocks, PLL0 and PLL1. Each PLL block contains a 'DPLL' (with NCO) and an 'APLL' (with VCO), followed by a '+2' multiplier and a '+Q' output stage. 'INTERNAL ZERO DELAY' lines connect the DPLL and APLL sections of each PLL. The PLL0 outputs are labeled 'DISTRIBUTION OUTPUTS' and include OUT0AP, OUT0AN, OUT0BP, OUT0BN, OUT0CP, and OUT0CN. The PLL1 outputs are labeled 'DISTRIBUTION OUTPUTS' and include OUT1AP, OUT1AN, OUT1BP, and OUT1BN. A 'SYSTEM CLOCK' is derived from the PLL outputs and passes through 'SYSTEM CLOCK PLL' and 'SYSTEM CLOCK COMPENSATION' (which is also connected to a 'TEMPERATURE SENSOR'). The 'SYSTEM CLOCK' is also connected to 'XOA' and 'XOB'. A 'SERIAL PORT (SPI/I2C) AND EEPROM CONTROLLER' is connected to the 'DIGITAL CROSS POINT MUX' and a 'SERIAL PORT'. The 'SERIAL PORT' is also connected to 'M0 TO M6' and an 'EEPROM (OPTIONAL)'. + +**Figure 2.3.3-2 Synchronizer Block Diagram** + +### 2.3.3.1.4 Reference Synthesizer + +The purpose of the clock synthesizer is to generate low jitter, high stability reference clocks as needed throughout the design. + +#### 2.3.3.1.4.1 Hardware Specifications + +##### 2.3.3.1.4.1.1 Interface + +**Table 2.3.3-4 Synthesizer Interface Specifications** + +| Item Name | Description | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Reference Clock(s) Input | The clock inputs device should receive a stable reference from a crystal, network reference or other suitable source. More than one input is allowed that may be selected between as required by the system. | +| Control | Control of the transceiver is by way of 3 or 4 wire SPI or I2C functioning as a slave. Support for 1.8V control is required and tolerance of 3.3V is preferred. Typically, the clock devices will be part of an IEEE1588v2 protocol loop controlled by way of this control interface or other GPIO lines as required by the hardware implementation. | +| Clock Outputs | One or more clock outputs are required to drive the digital device and transceiver clock inputs. Each output should be independently programmable in frequency to suit the application. The outputs should nominally be differential to preserve clocking edge and to maximize tolerance of high common mode signals. | + +#### 2.3.3.1.4.1.2 Performance Specifications + +**Table 2.3.3-5 TCXO Clock Performance Specifications** + +| Item Name | Description | +|----------------|--------------| +| Frequency | 25 MHz | +| Stability | +/- 0.28 ppm | +| 10 Hz Offset | -90 dBc/Hz | +| 100 Hz Offset | -120 dBc/Hz | +| 1 kHz Offset | -140 dBc/Hz | +| 10 kHz Offset | -151 dBc/Hz | +| 100 kHz Offset | -152 dBc/Hz | +| 1 MHz Offset | -154 dBc/Hz | + +### 2.3.3.1.4.2 Hardware Design + +Figure 2.3.3-3 depicts the hardware design of the Synthesizer Block + +![Figure 2.3.3-3 Synthesizer Block Diagram: A detailed hardware block diagram of a synthesizer. The diagram shows two main PLL blocks, PLL1 and PLL2. PLL1 is a fractional-N PLL with inputs REFA, REF_SEL, and REFB, containing 10-bit dividers, a switch-over control, a lock detect, a loop filter, a charge pump, and a PFD. PLL2 is a fractional-N PLL with inputs from PLL1, containing a 5-bit divider (R1), a PFD, a charge pump, a loop filter, a VCO, and a divider (+3, +4, +5). A control interface (SDI and I2C) with inputs SDO, SDIO/SDA, SCLK/SCL, CS, and RESET is connected to a status monitor (LOCK DETECT/SERIAL PORT ADDRESS) with outputs STATUS 0, 1 and SP0, 1. The control interface also generates an SPI SYS_REF REQUEST. A SYSREF_IN input is connected to a SYSREF GENERATION TRIGGER. The output of the trigger is connected to a series of 8-bit dividers with coarse delay and fine delay blocks, which are then connected to outputs OUT0, OUT1, OUT2 TO OUT11, OUT12, and OUT13. The diagram also shows various power and ground connections, including LF1, VCXO_VT, VCXO_IN, VCXO, LF2_CAP, and LDO_VCO.](4dce309123f1bcc76d97a45ba081853d_img.jpg) + +Figure 2.3.3-3 Synthesizer Block Diagram: A detailed hardware block diagram of a synthesizer. The diagram shows two main PLL blocks, PLL1 and PLL2. PLL1 is a fractional-N PLL with inputs REFA, REF\_SEL, and REFB, containing 10-bit dividers, a switch-over control, a lock detect, a loop filter, a charge pump, and a PFD. PLL2 is a fractional-N PLL with inputs from PLL1, containing a 5-bit divider (R1), a PFD, a charge pump, a loop filter, a VCO, and a divider (+3, +4, +5). A control interface (SDI and I2C) with inputs SDO, SDIO/SDA, SCLK/SCL, CS, and RESET is connected to a status monitor (LOCK DETECT/SERIAL PORT ADDRESS) with outputs STATUS 0, 1 and SP0, 1. The control interface also generates an SPI SYS\_REF REQUEST. A SYSREF\_IN input is connected to a SYSREF GENERATION TRIGGER. The output of the trigger is connected to a series of 8-bit dividers with coarse delay and fine delay blocks, which are then connected to outputs OUT0, OUT1, OUT2 TO OUT11, OUT12, and OUT13. The diagram also shows various power and ground connections, including LF1, VCXO\_VT, VCXO\_IN, VCXO, LF2\_CAP, and LDO\_VCO. + +Figure 2.3.3-3 Synthesizer Block Diagram + +## 2.3.4 External Interface Ports + +### 2.3.4.1 Hardware Specifications + +The following table shows the external ports or slots provided by the O-RU. External connections can be aggregated into a composite connector to minimize the points of environmental ingress as required for a specific deployment. + +**Table 2.3.4-1 External Port List** + +| Port Name | Feature Description | +|---------------------|----------------------------------------------------------------------------------------------------------------------------| +| Fronthaul interface | One or more 25Gbps optical interfaces including a primary link and optionally a second link for redundancy or daisy chain. | +| Debug interface | RJ45 for maintenance access. | +| Power interface | Two pin male panel mount connectors (x1) | +| RF Interface | 4.3-10+ IP67 connector (x4) [7]/M-LOC cluster/multiport RF connector [8] | + +### 2.3.4.2 Hardware Design for External Interfaces + +#### 2.3.4.2.1 Fronthaul Interface + +The fronthaul interface to the OMAC is provided by an optical fiber or fibers connected to the chassis by way of a SFP or SFP+ cage connector. In addition, an IP67 connector seal should be selected to provide appropriate environmental protection. + +![A 3D perspective drawing of an SFP+ (Small Form-factor Pluggable Plus) module. It is a rectangular component with a metal cage-like structure. The front face features several circular ports for optical fibers. The side of the module shows a series of pins or connectors for electrical interfacing with a host device.](4f03056698625890adbfc7ec6caa0808_img.jpg) + +A 3D perspective drawing of an SFP+ (Small Form-factor Pluggable Plus) module. It is a rectangular component with a metal cage-like structure. The front face features several circular ports for optical fibers. The side of the module shows a series of pins or connectors for electrical interfacing with a host device. + +**Figure 2.3.4-1 SFP+ case and connector** + +#### 2.3.4.2.2 Debug Interface + +The local maintenance port or debug port is by way of a standard ethernet connector. The RJ45 Ethernet connector are standardized components and available from multiple vendors. The following figure describes the general form factor of one such RJ45 connector. + +![3D isometric drawing of an RJ45 interface connector, showing the standard 8-pin Ethernet port with a shielded metal housing and a latch mechanism.](9c5249266b967bea1a41c9fa9fe97f96_img.jpg) + +3D isometric drawing of an RJ45 interface connector, showing the standard 8-pin Ethernet port with a shielded metal housing and a latch mechanism. + +**Figure 2.3.4-2 RJ45 Interface** + +#### 2.3.4.2.3 Power Interface + +The standard power interface is defined by a 2-pin panel mount connector as shown in the following figure. + +![3D rendering of a power interface connector. It consists of a square panel mount connector with two pins and a circular RF connector with a central pin, connected by a thin wire.](fc2e3c4028983eac7d8cea231280ce9e_img.jpg) + +3D rendering of a power interface connector. It consists of a square panel mount connector with two pins and a circular RF connector with a central pin, connected by a thin wire. + +**Figure 2.3.4-3 Power Interface** + +#### 2.3.4.2.4 RF Interface + +The standard RF interfaces are the 4.3-10+ Low PIM RF connector and the M-LOC cluster/multiport connector as shown in the following figure. + +![Figure 2.3.4-4 (a) 4.3-10+ RF Connector [7] and (b) M-LOC Cluster/multiport connector [8]](397b9da046463e68f3ce2d32778395f8_img.jpg) + +(a) + +(b) + +Figure 2.3.4-4 (a) 4.3-10+ RF Connector [7] and (b) M-LOC Cluster/multiport connector [8] + +**Figure 2.3.4-4 (a) 4.3-10+ RF Connector [7] and (b) M-LOC Cluster/multiport connector [8]** + +### 2.3.5 Mechanical + +One such mechanical structure is shown in the following figure. The shell should provide appropriate environmental protection, RF shielding and passive thermal dissipation. Internally, thermal pads are used to contact local heat sources and transfer that heat to the frame which in turn dissipates the heat through bulk metal and fins used to increase the effective surface area. Other enclosures are possible. + +![Figure 2.3.5-1 Mechanical Enclosure Front View: A 3D rendering of a rectangular metal enclosure with vertical cooling fins. It features two lifting rings at the top, a handle on the left, and multiple connectors at the bottom. Dimensions are shown: 410 mm height and 330 mm width.](7fff3e33a4bb036da4ac7edb2c6ebf98_img.jpg) + +Figure 2.3.5-1 Mechanical Enclosure Front View: A 3D rendering of a rectangular metal enclosure with vertical cooling fins. It features two lifting rings at the top, a handle on the left, and multiple connectors at the bottom. Dimensions are shown: 410 mm height and 330 mm width. + +**Figure 2.3.5-1 Mechanical Enclosure Front View** + +![Figure 2.3.5-2 Mechanical Enclosure Top View: A 3D rendering of the top of the enclosure, showing a rectangular metal frame with two horizontal locking bolts and ventilation slots. A dimension of 170 mm is indicated on the right side.](e065d418f12edd03b227136babcfe39f_img.jpg) + +Figure 2.3.5-2 Mechanical Enclosure Top View: A 3D rendering of the top of the enclosure, showing a rectangular metal frame with two horizontal locking bolts and ventilation slots. A dimension of 170 mm is indicated on the right side. + +**Figure 2.3.5-2 Mechanical Enclosure Top View** + +## 2.3.6 Power Unit + +For the Outdoor Macrocell, the power solution of the O-RU is provided externally from a telco -48V supply. Internally, the telco supply is converted and distributed to devices using appropriate DC-DC and LDO converters. Optionally the unit can be powered by AC line power which is not shown here. + +### 2.3.6.1 Hardware Specifications + +The power unit is responsible for isolating and converting the telco supply to appropriate voltages for distribution to individual supply domains in the O-RU. The worst-case dissipation is outlined below. The RF front end is broken out separately since different deployment scenarios will require different frequencies and power levels resulting in significantly different total dissipation. Total Power is the sum of transceiver module section and RF front end module section. + +**Table 2.3.6-1 Transceiver Module Specifications** + +| Module | 4T4R (Watts) | | Notes | +|--------------------------------------------|--------------|--|----------------------| +| FPGA | 25 W | | | +| Transceiver | 10 W | | | +| Synchronization & Clocking | 1.8 W | | | +| DDR | 1.8 W | | 4 modules | +| Others | 6 W | | | +| SFP28 Module | 4 W | | 2 modules | +| total device consumption | 48.6 W | | | +| O-RU Low PHY Transceiver power consumption | 54 W | | 90% power efficiency | + +**Table 2.3.6-2 RF Front End Module Specifications** + +| Module | 4T4R (Watts) | | Notes | +|-------------------------------------|--------------|--|-------------------------| +| PA | 330-350 | | 40W O/P at Antenna Port | +| PA Drive Amp | 30-35 | | 2W O/P Power | +| LNA | 1.5 – 2.0 | | For 4 chains | +| Others | 10-13 | | Gain Block and Switch | +| total device consumption | 344.5 – 400 | | 80% Duty Cycle | +| O-RU RF Front End power consumption | 495 | | Total Power Consumption | + +## 2.3.6.2 Hardware Design + +The block diagram of the power unit is shown in Figure 2.3.6-1. + +![Block diagram of the power unit showing the flow from -48V Telco Supply through a Power Connector, Isolated Power Module, and Local Supply Generators (DC-DC & LDO) to the output.](d61054715824de90884b91b8c2380e94_img.jpg) + +``` + +graph LR + A["-48V +Telco Supply"] --- B["Power +Connector"] + B --- C["Isolated +Power +Module"] + C --- D["Local Supply +Generators +(DC-DC & LDO)"] + D --- E["n"] + C --- GND1[Ground] + D --- GND2[Ground] + +``` + +Block diagram of the power unit showing the flow from -48V Telco Supply through a Power Connector, Isolated Power Module, and Local Supply Generators (DC-DC & LDO) to the output. + +![Figure 2.3.6-1 Power Reference Design diagram. The diagram shows a power distribution system starting from a 'Telco supply (-48 V)' input. This input goes into a protection module containing 'Over Voltage Protection Module, Over Current Protection Module, Reverse polarity module, and EMI Filter'. The output of this module splits into two paths. One path goes to 'Isolated Module #1', which outputs '12 V/ 5V' to 'Local Supply Generators (DC-DC & LDO)/ Buck Converter for FPGA/Digital Board'. The other path goes to 'Isolated Module #2', which outputs '50 V/ 28 V' to 'Local Supply Generators (DC-DC & LDO)/ Buck Converter for PAM Tile/Board #1' and 'Local Supply Generators (DC-DC & LDO)/ Buck Converter for PAM Tile/Board #n'. A 'BMC' (Baseband Module Controller) is connected to the 50 V/ 28 V line. Each local supply generator outputs a range of voltages and powers, indicated by '...V to ...V @ ...W'.](13445caecbc7a80fbfa5be8606c13a97_img.jpg) + +Figure 2.3.6-1 Power Reference Design diagram. The diagram shows a power distribution system starting from a 'Telco supply (-48 V)' input. This input goes into a protection module containing 'Over Voltage Protection Module, Over Current Protection Module, Reverse polarity module, and EMI Filter'. The output of this module splits into two paths. One path goes to 'Isolated Module #1', which outputs '12 V/ 5V' to 'Local Supply Generators (DC-DC & LDO)/ Buck Converter for FPGA/Digital Board'. The other path goes to 'Isolated Module #2', which outputs '50 V/ 28 V' to 'Local Supply Generators (DC-DC & LDO)/ Buck Converter for PAM Tile/Board #1' and 'Local Supply Generators (DC-DC & LDO)/ Buck Converter for PAM Tile/Board #n'. A 'BMC' (Baseband Module Controller) is connected to the 50 V/ 28 V line. Each local supply generator outputs a range of voltages and powers, indicated by '...V to ...V @ ...W'. + +Figure 2.3.6-1 Power Reference Design + +## 2.3.7 Thermal + +Heat dissipation in the O-RU is widely done through passive cooling via three modes: conduction, convection, and radiation. These mechanisms are accomplished with the help of heat sink, heat pipes and vapor chamber etc. + +The transfer of heat though conduction can usually be described by Fourier's law, which is stated + +$$q=(k/s)A.dT$$ + +k is the thermal conductivity of the material, and has units of W/m·K, s = material thickness, A = heat transfer area, dT = temperature difference between inside and outside wall. + +Table 2.3.7-1 Thermal Conductivity of common Metals [9] + +| Type of Material | Thermal Conductivity (W/m,K) | +|-----------------------|------------------------------| +| Diamond | 2300 | +| Pure Al | 237 | +| Hard Aluminum 4.5% Cu | 315-317 | +| Au | 411-429 | +| Iron | 80 | +| Tin | 67 | + +The heat sinks transfer heat to space by thermal convection and radiation. For thermal convection, it can be calculated by the Newton's Equation: + +$$Q_d = \alpha_c A \Delta t = \alpha_c A (t_\omega - t_f)$$ + +where, + +$Q_d$ is the convection heat (W), $t_\omega$ is the surface temperature of object (K), $t_f$ is the temperature of airflow (K), + +A is the surface area of the object involved in heat transfer (m<sup>2</sup>), $\Delta t$ is the temperature difference between the surface temperature of object and airflow (K), $\alpha_c$ is convective heat transfer coefficient (W/m<sup>2</sup>.K). + +**Table 2.3.7-2 Convective heat transfer coefficient [10]** + +| Flow Type | Heat transfer coefficients (W/m <sup>2</sup> . K) | +|--------------------------------------------------------------------|---------------------------------------------------| +| Forced convection; low speed flow of air over a surface | 10 | +| Forced convection; moderate speed flow of air over a surface | 100 | +| Forced convection; moderate speed crossflow of air over a cylinder | 200 | +| Forced convection; moderate flow of water in pipe | 3000 | + +For thermal radiation, it can be calculated by the following Equation: + +$$Q_r = \varepsilon \delta A (t_w^4 - t_f^4)$$ + +where, $Q_r$ is the radiation heat (W), $\varepsilon$ is the thermal emissivity, $\delta$ is the Stefan– Boltzmann constant, its value is $5.67032 \times 10^{-8} \text{ W/ (m}^2 \cdot \text{K}^{-4})$ . From these Equations, we can see that the increase of surface area A and thermal emissivity $\varepsilon$ will improve the heat dissipation. + +Different materials can have widely different emissivity values within the range of 0 to 1.00. + +**Table 2.3.7-3 Emissivity value of different materials [11]** + +| Material | Emissivity Value ( $\varepsilon$ ) | +|---------------------------------|------------------------------------| +| Aluminum: anodized | 0.77 | +| Aluminum: polished | 0.05 | +| Brass: highly polished | 0.03 | +| Brass: oxidized | 0.61 | +| Carbon: candle soot | 0.95 | +| Carbon: graphite, filed surface | 0.98 | +| Copper: polished | 0.05 | +| Copper: oxidized | 0.65 | + +## 2.3.8 Environmental and Regulations + +The O-RU hardware system is RoHS Compliant. The unit is passively cooled. + +**Table 2.3.8-1 Environmental Features** + +| Item Name | Description | Notes | +|-----------------------------|----------------|--------------------| +| Operating Temperature | -40°C to +55°C | Cold and hot start | +| Operating Relative Humidity | 5% to 95% | | +| Atmospheric Pressure | 70 to 106Kpa | | + +## 2.4 Integrated O-DU & O-RU (gNB-DU) Reference Design + +The integrated hardware consists of O-DU & O-RU in a single box. The integrated O-DU & O-RU is the white box hardware platform that performs the O-DU functions such as upper L1 and lower L2 functions along with O-RU. The integrated small cell (gNB-DU) shall support split option – 2 (F1 Interface) towards gNB-CU and supports FAPI standard logical interface between Layer2 and Layer1 running on different HW options. + +![Figure 2.3.8-1 Integrated O-DU & O-RU (gNB-DU) Reference Design block diagram. The diagram shows an 'Integrated gNB-DU' block containing several components: 'Optical Interface', 'Ethernet Interface', 'Central Processing Unit', 'Digital Processing Unit', 'Transceiver', 'RF Frontend', 'Clock', and 'Power Unit'. The 'Optical Interface' and 'Ethernet Interface' are connected to 'Midhaul' and 'To/From O-CU'. The 'Central Processing Unit' and 'Digital Processing Unit' are connected to each other and to the 'Transceiver'. The 'Transceiver' is connected to the 'RF Frontend', which is connected to multiple antennas. The 'Clock' and 'Power Unit' provide power to the 'Central Processing Unit', 'Digital Processing Unit', and 'Transceiver'.](bc79d6fd9a39064fa6165e38ff9aacb3_img.jpg) + +Figure 2.3.8-1 Integrated O-DU & O-RU (gNB-DU) Reference Design block diagram. The diagram shows an 'Integrated gNB-DU' block containing several components: 'Optical Interface', 'Ethernet Interface', 'Central Processing Unit', 'Digital Processing Unit', 'Transceiver', 'RF Frontend', 'Clock', and 'Power Unit'. The 'Optical Interface' and 'Ethernet Interface' are connected to 'Midhaul' and 'To/From O-CU'. The 'Central Processing Unit' and 'Digital Processing Unit' are connected to each other and to the 'Transceiver'. The 'Transceiver' is connected to the 'RF Frontend', which is connected to multiple antennas. The 'Clock' and 'Power Unit' provide power to the 'Central Processing Unit', 'Digital Processing Unit', and 'Transceiver'. + +**Figure 2.3.8-1 Integrated O-DU & O-RU (gNB-DU) Reference Design** + +### 2.4.1 O-DU Portion of Integrated Reference Design + +In this Integrated architecture, several functions are included such as DDR4, QSPI, 1G Ethernet, SFP, PCIe, JTAG, UART, and EMMC. + +#### 2.4.1.1 O-DU High-Level Functional Block Diagram + +In the following O-DU portion in the integrated architecture it shows the interconnection of the Components and external interfaces. O-DU portion is connected to O-RU portion via PCIe interface. + +![Functional Block Diagram for O-DU portion showing the CPU Central Processing Unit connected to various components.](fa04ba5c7b3bdf566569c96c21bb1c6e_img.jpg) + +The diagram illustrates the functional block diagram for the O-DU portion. A central block labeled "CPU Central Processing Unit" is enclosed in a dashed box labeled "O-DU". Above this box is a "Clock Synchronizer" block with a downward arrow pointing to the CPU. To the left of the CPU, there are four blocks: "SFP", "Ethernet", "JTAG", and "EMMC", each connected to the CPU with a double-headed arrow. Below the CPU, there are three blocks: "DDR4", "UART", and "EMMC", each connected to the CPU with a double-headed arrow. To the right of the CPU, there is a "To/From FPGA/ASIC" block connected to the CPU with a double-headed arrow, and a "PCIe Interface" block connected to the CPU with a single-headed arrow pointing towards the CPU. Below the CPU, there is a "System Management Controller" block connected to the CPU with a double-headed arrow. To the right of the System Management Controller are three blocks: "Temp Sensor", "Power Monitor", and "EEPROM", each connected to the System Management Controller with a single-headed arrow. At the bottom, there is a "Power Unit" block connected to the CPU with a single-headed arrow pointing towards the CPU. + +Functional Block Diagram for O-DU portion showing the CPU Central Processing Unit connected to various components. + +Figure 2.4.1-1 Functional Block Diagram For O-DU portion + +## 2.4.1.2 O-DU Hardware Components + +[Intentionally left blank awaiting future contributions] + +### 2.4.1.2.1 Digital Processing Unit + +### 2.4.1.2.2 Hardware Accelerator (if required by design) + +#### 2.4.1.2.2.1 Accelerator Design 1 + +#### 2.4.1.2.2.2 Accelerator Design 2 + +### 2.4.1.3 Synchronization and Timing + +## 2.4.2 O-RU Portion of Integrated Reference Design + +In this Integrated architecture the O-RU portion contains the Digital Processing Unit Processing Unit, including the Transceiver, RFFE and other RF components, Clock and Synchronization & Power Unit. Digital processing unit is connected to O-DU portion NPU through PCIe interface. + +### 2.4.2.1 O-RU High-Level Functional Block Diagram + +This is high level functional block diagram for O-RU portion in the Integrated architecture. + +It also highlights the internal/external interfaces that are required. + +![Figure 2.4.2-1 Functional Block Diagram for O-RU portion. The diagram shows the internal architecture of an O-RU. On the left, a 'To/From CPU PCIe Interface' connects to the 'FPGA/ASIC Digital Processing Unit'. This unit is connected to 'DDR4' and 'FLASH' memory blocks. It also interfaces with a 'Clock Synchronizer' and a 'Power Unit'. The 'FPGA/ASIC Digital Processing Unit' is connected via a 'JESD204B' interface to the 'RF Transceiver'. The 'RF Transceiver' contains a 'DAC' and an 'ADC'. The 'RF Transceiver' is connected to the 'RF Front-End Unit'. The 'RF Front-End Unit' includes a 'Tx Section' with 'BPF' and 'PA' blocks, and an 'Rx Section' with 'BPF' and 'LNA' blocks. The 'RF Front-End Unit' is connected to a 'FILTER BANK' which has multiple antenna ports.](b5e2ec01242503d08905c82bb0b4dda1_img.jpg) + +Figure 2.4.2-1 Functional Block Diagram for O-RU portion. The diagram shows the internal architecture of an O-RU. On the left, a 'To/From CPU PCIe Interface' connects to the 'FPGA/ASIC Digital Processing Unit'. This unit is connected to 'DDR4' and 'FLASH' memory blocks. It also interfaces with a 'Clock Synchronizer' and a 'Power Unit'. The 'FPGA/ASIC Digital Processing Unit' is connected via a 'JESD204B' interface to the 'RF Transceiver'. The 'RF Transceiver' contains a 'DAC' and an 'ADC'. The 'RF Transceiver' is connected to the 'RF Front-End Unit'. The 'RF Front-End Unit' includes a 'Tx Section' with 'BPF' and 'PA' blocks, and an 'Rx Section' with 'BPF' and 'LNA' blocks. The 'RF Front-End Unit' is connected to a 'FILTER BANK' which has multiple antenna ports. + +**Figure 2.4.2-1 Functional Block Diagram for O-RU portion** + +## 2.4.2.2 O-RU Hardware Components + +[Intentionally left blank awaiting future contributions] + +### 2.4.2.2.1 Digital Processing Unit + +### 2.4.2.2.2 RF Processing Unit + +#### 2.4.2.2.2.1 Transceiver Reference Design + +#### 2.4.2.2.2.2 Power Amplifier (PA) Reference Design + +#### 2.4.2.2.2.3 Low Noise Amplifier (LNA) Reference Design + +#### 2.4.2.2.2.4 RF Switch Reference Design + +#### 2.4.2.2.2.5 Antenna / Phased Array Reference Design + +Phased array antenna reference design is shown in the Figure 2.4.2-2 + +![Figure 2.4.2-2 Phased array antenna reference design block diagram. The diagram shows the O-RU hardware components divided into three main subsystems: Digital Subsystem, RF Front End Subsystem, and Antenna Subsystem. The Digital Subsystem includes a 'To/From CPU PCIe Interface' connected to an 'FPGA/ASIC DSP and RF Transceiver' block, which contains 'Beam Weight generation' (DAC), 'ADC', and 'FPGA/ASIC DSP and RF Transceiver' blocks. The RF Front End Subsystem includes a 'Tx RF Chain' with multiple parallel paths (W1, W2, W3, ..., Wn) each containing a BPF, ATN, and PA, and an 'Rx RF Chain' with multiple parallel paths each containing a BPF and LNA. A 'T/R Switch' and 'Cavity Filter' are also shown. The Antenna Subsystem includes an 'Array antenna' with 'Antenna RF Ports #1, #2, #3, ..., #n' and an 'Antenna Calibration Port'. The 'Power Unit' is connected to the RF Front End Subsystem. The 'Antenna Calibration' block is connected to the Array antenna.](4e709eaacfffa9cdb2e5b94fb173a796_img.jpg) + +Figure 2.4.2-2 Phased array antenna reference design block diagram. The diagram shows the O-RU hardware components divided into three main subsystems: Digital Subsystem, RF Front End Subsystem, and Antenna Subsystem. The Digital Subsystem includes a 'To/From CPU PCIe Interface' connected to an 'FPGA/ASIC DSP and RF Transceiver' block, which contains 'Beam Weight generation' (DAC), 'ADC', and 'FPGA/ASIC DSP and RF Transceiver' blocks. The RF Front End Subsystem includes a 'Tx RF Chain' with multiple parallel paths (W1, W2, W3, ..., Wn) each containing a BPF, ATN, and PA, and an 'Rx RF Chain' with multiple parallel paths each containing a BPF and LNA. A 'T/R Switch' and 'Cavity Filter' are also shown. The Antenna Subsystem includes an 'Array antenna' with 'Antenna RF Ports #1, #2, #3, ..., #n' and an 'Antenna Calibration Port'. The 'Power Unit' is connected to the RF Front End Subsystem. The 'Antenna Calibration' block is connected to the Array antenna. + +**Figure 2.4.2-2 Phased array antenna reference design** + +It has the following functional blocks: + +#### 1. Digital Front-end Block: + +It is responsible for processing the baseband data and controlling the beams of the antenna. It has two basic functional blocks that are described below. + +- a. FPGA/Baseband processor - To generate/apply the weights (Amplitude and phase) to the phased array antenna elements based on the beam characteristics. Also, it is responsible for scheduling the data/control symbols in each transceiver chain. +- b. DSP/Algorithm block: It works together with the FPGA to generate the weight matrix and map the same to the corresponding antenna element. + +2. RF Front-end Block: + +It has attenuator, amplifiers (PA in the Tx and LNA in the Rx chain), switches and duplexer (to switch between Tx/Rx chain or Downlink/Uplink) + +3. Plurality of antenna elements: + +Two or more antenna elements are there in the phased array antenna to attain the below desired beam characteristics upon application of the corresponding beam weights, which are estimated based on the CSI/SRS measurements. + +- a. Beam splitting (Hard and Soft) - Twin beam, Quad beam etc... +- b. Beam steering +- c. Plurality of beams (Service beam (Sectoral) and multiple narrow beams) +- d. Beam refinement +- e. Generating null in the desired direction +- f. Tilting of the beams + +2.4.2.2.3 Synchronization and Timing + +2.4.3 External Interface Ports + +2.4.4 O-DU/O-RU Firmware (if required by design) + +2.4.5 Mechanical + +2.4.6 Power Unit + +2.4.7 Thermal + +2.4.8 Environmental and Regulations + +## 2.5 O- RU<sub>7-2x</sub> Massive MIMO Hardware Reference Design + +Massive Multiple Input and Multiple Output (mMIMO), as one of the key enablers of 5G NR that enhances the user experience by employing the spatial multiplexing, beamforming, and spatial diversity methods. This O-RU<sub>7-2x</sub> consists of several digital baseband and RF processing units and several antenna elements, which occupy the larger footprint along with power hungry components that lead to high cost and volume. mMIMO O-RU<sub>7-2x</sub> can be realized with different high level radio architecture based on various functional splits and interface/interconnects between these functional blocks. + +### 2.5.1 O-RU<sub>7-2x</sub> Massive MIMO High-Level Functional Block Diagram + +The level of integration achieved on a SoC for different functional blocks can vary and that in turn can result in different O-RU<sub>7-2x</sub> architecture and the associated interconnects between the functional blocks. + +These functional splits can be realized through three possible configurations of O-RU<sub>7-2x</sub> mMIMO Architecture options and they are discussed in detail in the sections below. All configurations have the same three major functional blocks like O-RAN Fronthaul Processing Unit, Digital Processing Unit, and RF Processing unit. + +For any O-RU<sub>7-2x</sub> mMIMO Architecture option, the eCPRI frame that comes from O-DU<sub>7-2x</sub> is compressed/decompressed and processed by the O-RAN Fronthaul Processing Unit & Beamformer block. The Digital Processing Unit, which has a FPGA/ASIC based DFE and AFE modules, receives the packets/digital signals (depending on the architecture used) from O-RAN Fronthaul Processing Unit & Beamformer block and performs the functionalities such as compression/decompression (if applicable), Low-PHY (if applicable), DDC, DUC, CFR, DPD, ADC and DAC. All these three functional blocks can be part of a single SoC or can be split into multiple physical integrated circuits (IC) and connected with a digital or packet-based interface. The functional block labelled RF processing block consists of an optional frequency converter (mixer), Power Amplifier (PA)/ Low Noise Amplifier (LNA). The filter is the next functional block in the path and is needed for each of the N Tx/Rx paths to meet the emissions in the DL and provide the necessary selectivity for UL. The last functional block in the mMIMO RU system is the Antenna. Depending on the power level for each of the Tx chain in a mMIMO system, the filter could be integrated into the RF Section or could be integrated along with the antenna thus making it the AFU. A detailed description of the O-RAN Fronthaul Processing, Digital, and RF Processing blocks is discussed in Section 2.3.2. + +In a mMIMO O-RU, Tx/Rx reciprocity calibration is one of the important steps for optimal performance. Calibration is required to align the Tx and Rx chains in phase and amplitude. In some implementations, reciprocity calibration requires implementing a dedicated feedback path. Multiple options are possible for the design of such a feedback path – the main three options are shown in Figure 2.5.1-1, Figure 2.5.1-2, and Figure 2.5.1-3. The main difference between each of the calibration options is the implementation of the feedback network and where the RF feedback and associated distribution circuitry reside. The calibration signal ultimately needs to be relayed back to the AFE, so that the phase and amplitude difference between each of the corresponding Tx-Rx chain and the phase and amplitude differences between the multiple Tx- + +Rx chains can be estimated and calibrated accurately to ensure uplink and downlink channel reciprocity to enable beamforming. + +In Calibration option #1, the RF feedback and the distribution circuitry resides in the antenna module and all the RF components including the antenna are part of the Tx/Rx reciprocity calibration loop. In Calibration option #2, the RF feedback and the distribution circuitry resides in the filter module and all the RF components till the filter module are part of the Tx/Rx reciprocity calibration. In Calibration option #3, the RF feedback and the distribution circuitry resides in the RF Section and all the RF components till the RF Section's output in the Tx path and input in the Rx path are part of the Tx/Rx reciprocity calibration. These calibration options (CAL option #1, #2 and #3) can apply to all three mMIMO O-RU architectures in Figure 2.5.1-1, Figure 2.5.1-2, and Figure 2.5.1-3. It is also worth mentioning that other calibration options are possible where calibration feedback is not needed. + +### 2.5.1.1 O-RU<sub>7-2x</sub> Massive MIMO High Level Architecture Option #1 + +![Figure 2.5.1-1 [NxM]T[NxM]R mMIMO O-RU7-2x High Level System Architecture #1. The diagram shows a block diagram of the system architecture. It includes an ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer connected to a Digital Processing Unit (DFE, AFE) via a Packet Interface. The DFE block contains (De-) Compression, Low-Phy, DDC, DUC, CFR, and DPD. The AFE block contains ADC and DAC. The Digital Processing Unit is connected to an RF Processing unit via an RF Interface. The RF Processing unit contains an RF section (N x Tx/Rx/ LNA/PA), a Filter (N), and an Antenna (N ports). The RF section is connected to the Filter, which is connected to the Antenna. The RF section also includes Tx/Rx Reciprocity CAL Option #1, #2. The Antenna includes Tx/Rx Reciprocity CAL Option #3. The entire system is powered by a POWER SUPPLY and has a Timing block. An Optical interface to/from O-DU2x is shown on the left. A dashed box labeled 'Optional integration' is shown on the right.](bae62e77927998f9999c32dde93f767f_img.jpg) + +Figure 2.5.1-1 [NxM]T[NxM]R mMIMO O-RU7-2x High Level System Architecture #1. The diagram shows a block diagram of the system architecture. It includes an ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer connected to a Digital Processing Unit (DFE, AFE) via a Packet Interface. The DFE block contains (De-) Compression, Low-Phy, DDC, DUC, CFR, and DPD. The AFE block contains ADC and DAC. The Digital Processing Unit is connected to an RF Processing unit via an RF Interface. The RF Processing unit contains an RF section (N x Tx/Rx/ LNA/PA), a Filter (N), and an Antenna (N ports). The RF section is connected to the Filter, which is connected to the Antenna. The RF section also includes Tx/Rx Reciprocity CAL Option #1, #2. The Antenna includes Tx/Rx Reciprocity CAL Option #3. The entire system is powered by a POWER SUPPLY and has a Timing block. An Optical interface to/from O-DU2x is shown on the left. A dashed box labeled 'Optional integration' is shown on the right. + +**Figure 2.5.1-1 [NxM]T[NxM]R mMIMO O-RU<sub>7-2x</sub> High Level System Architecture #1** + +In this section, the diagram of NxM mMIMO O-RU<sub>7-2x</sub> High Level System Architecture option #1 is provided. This is a difference factor from the other architectures. In this example the Low-PHY functionalities are implemented in DFE block and ADC and DAC converters are in the AFE block, both of them inside Digital Processing Unit. + +### 2.5.1.2 O-RU<sub>7-2x</sub> Massive MIMO High Level Architecture Option #2 + +In the mMIMO O-RU<sub>7-2x</sub> High Level System Architecture #2, the operations that are performed in DFE of mMIMO O-RU High Level System Architecture #1 are distributed between the O-RAN Fronthaul Processing Unit & Beamformer and AFE as shown in Figure 2.5.1-2. In particular, the Low-PHY functions of DFE are performed in the ASIC/FPGA for O-RAN Fronthaul Processing Unit & Beamformer and DDC, DUC, CFR, and DPD blocks of DFE are part of AFE in the RFIC as shown in Figure 2.5.1-2. The interconnection between the ORAN Fronthaul Processing Unit & Beamformer and Digital Processing Unit will be done through a digital interface since the Low-PHY is in the first block in this option. + +![Figure 2.5.1-2: High Level System Architecture #2. This block diagram shows the architecture of an O-RU. On the left, an 'Optical interface to/from O-DU_{2x}' connects to the 'ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer'. This unit is connected via a 'Digital Interface' to the 'Digital Processing Unit'. The Digital Processing Unit is further connected via an 'RF interface' to the 'DFE & AFE N x Tx/Rx' block, which contains 'DDC, DUC, CFR, DPD, ADC, DAC'. This block is connected via an 'RF interface' to the 'RF section N x Tx/Rx/LNA/PA'. The RF section is connected to a 'Filter N', which is connected to 'Antenna N ports'. A 'Timing' block is connected to the ORAN Fronthaul Processing Unit, the Digital Processing Unit, and the DFE & AFE block. A 'POWER SUPPLY' block is connected to the ORAN Fronthaul Processing Unit, the Digital Processing Unit, the DFE & AFE block, and the RF section. A 'Tx/Rx Reciprocity CAL Option #3' block is connected to the RF section and the Antenna N ports. A 'Tx/Rx Reciprocity CAL Option #1, #2' block is connected to the RF section and the Filter N. An 'Optional Integration' block is shown on the right.](0d05f166f9e3fe350d30075e5d6cf3a6_img.jpg) + +Figure 2.5.1-2: High Level System Architecture #2. This block diagram shows the architecture of an O-RU. On the left, an 'Optical interface to/from O-DU\_{2x}' connects to the 'ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer'. This unit is connected via a 'Digital Interface' to the 'Digital Processing Unit'. The Digital Processing Unit is further connected via an 'RF interface' to the 'DFE & AFE N x Tx/Rx' block, which contains 'DDC, DUC, CFR, DPD, ADC, DAC'. This block is connected via an 'RF interface' to the 'RF section N x Tx/Rx/LNA/PA'. The RF section is connected to a 'Filter N', which is connected to 'Antenna N ports'. A 'Timing' block is connected to the ORAN Fronthaul Processing Unit, the Digital Processing Unit, and the DFE & AFE block. A 'POWER SUPPLY' block is connected to the ORAN Fronthaul Processing Unit, the Digital Processing Unit, the DFE & AFE block, and the RF section. A 'Tx/Rx Reciprocity CAL Option #3' block is connected to the RF section and the Antenna N ports. A 'Tx/Rx Reciprocity CAL Option #1, #2' block is connected to the RF section and the Filter N. An 'Optional Integration' block is shown on the right. + +**Figure 2.5.1-2 [N<sub>x</sub>M]T[N<sub>x</sub>M]R mMIMO O-RU<sub>7-2x</sub> High Level System Architecture #2** + +### 2.5.1.3 O-RU<sub>7-2x</sub> Massive MIMO High Level Architecture Option #3 + +In the mMIMO O-RU<sub>7-2x</sub> High Level System Architecture #3, DFE and AFE functions are combined on a single DFE & AFE functional module as shown in Figure 2.5.1-3. In this architecture, (De-)Compression, Low-PHY, DDC, DUC, CFR, and DPD are part of the same FPGA/ASIC. There is a packet-based interface/interconnect between the O-RAN Fronthaul Processing Unit & Beamformer and the DFE & AFE functional module. These modules can be on a single SoC or can be on different FPGA/ASIC. + +![Figure 2.5.1-3: High Level System Architecture #3. This block diagram shows the architecture of an O-RU. On the left, an 'Optical interface to/from O-DU_{2x}' connects to the 'ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer'. This unit is connected via a 'Packet Interface' to the 'DFE & AFE N x Tx/Rx' block, which contains '(De-) Compression, Low-PHY, DDC, DUC, CFR, DPD, ADC, DAC'. This block is connected via an 'RF interface' to the 'RF section N x Tx/Rx/LNA/PA'. The RF section is connected to a 'Filter N', which is connected to 'Antenna N ports'. A 'Timing' block is connected to the ORAN Fronthaul Processing Unit, the Digital Processing Unit, and the DFE & AFE block. A 'POWER SUPPLY' block is connected to the ORAN Fronthaul Processing Unit, the Digital Processing Unit, the DFE & AFE block, and the RF section. A 'Tx/Rx Reciprocity CAL Option #3' block is connected to the RF section and the Antenna N ports. A 'Tx/Rx Reciprocity CAL Option #1, #2' block is connected to the RF section and the Filter N. An 'Optional Integration' block is shown on the right.](6f925fc59ee100548f0a4b96ebf5e248_img.jpg) + +Figure 2.5.1-3: High Level System Architecture #3. This block diagram shows the architecture of an O-RU. On the left, an 'Optical interface to/from O-DU\_{2x}' connects to the 'ORAN Fronthaul Processing Unit (C, U, S, M plane) & Beamformer'. This unit is connected via a 'Packet Interface' to the 'DFE & AFE N x Tx/Rx' block, which contains '(De-) Compression, Low-PHY, DDC, DUC, CFR, DPD, ADC, DAC'. This block is connected via an 'RF interface' to the 'RF section N x Tx/Rx/LNA/PA'. The RF section is connected to a 'Filter N', which is connected to 'Antenna N ports'. A 'Timing' block is connected to the ORAN Fronthaul Processing Unit, the Digital Processing Unit, and the DFE & AFE block. A 'POWER SUPPLY' block is connected to the ORAN Fronthaul Processing Unit, the Digital Processing Unit, the DFE & AFE block, and the RF section. A 'Tx/Rx Reciprocity CAL Option #3' block is connected to the RF section and the Antenna N ports. A 'Tx/Rx Reciprocity CAL Option #1, #2' block is connected to the RF section and the Filter N. An 'Optional Integration' block is shown on the right. + +**Figure 2.5.1-3 [N<sub>x</sub>M]T[N<sub>x</sub>M]R mMIMO O-RU<sub>7-2x</sub> High Level System Architecture #3** + +## 2.5.2 O-RU<sub>7-2x</sub> Massive MIMO Hardware Reference Design Architecture + +The mMIMO O-RU<sub>7-2x</sub> hardware reference design architecture examples of 32T32R and 64T64R are shown in Figure 2.5.2-1 and Figure 2.5.2-2, respectively. + +The 32T32R and 64T64R hardware architectures shown in Figure 2.5.2-1 and Figure 2.5.2-2, respectively, have four major functional blocks such as ORAN fronthaul processing, digital processing, RF processing (RF transceiver and RF front end units), and antenna units and Section 2.5.1 describes each of these blocks. The ORAN fronthaul processing unit is connected with the digital processing unit through a packet interface. The Digital processing unit is connected to the RF processing unit through a digital interface with an interface such as JESD204. In the RF processing block, the RF Transceiver communicates with the RF front end using an RF interface. The RF transceiver unit has four RFICs that cater for 32T32R i.e., thirty-two transceiver + +chains, where each RFIC contains eight transceiver chains as shown in Figure 2.5.2-1. Similarly, the RF transceiver unit of 64T64R shown in Figure 2.5.2-2 has eight RFICs. RF front end units are accordingly connected to the transceiver chains. + +RF front end units connected with the antenna array with the 96 antenna elements, where each element is dual polarized (Vertical and Horizontal) thereby total number of antenna elements are 192. The antenna elements can be grouped in different ways. As an example, these elements can be arranged in two rows vertically and eight columns horizontally, where each row has 6 element sub arrays for 32T32R as shown in Figure 2.5.2-1. Similarly, for 64T64R, 96 antenna elements can be arranged in four rows vertically and eight columns horizontally, where each row has 3 element sub arrays as shown in Figure 2.5.2-2. The transceiver output can be either equally or not (following a specific criterion) fed to the all the subarray elements at the same time with the help of a power divider. Moreover, the antenna calibration process is described in detail in Section 2.5.1. + +![Figure 2.5.2-1 mMIMO O-RU7-2x hardware reference design architecture example of 32T32R. The diagram shows a block diagram of the hardware architecture. On the left is the 'O-RAN Fronthaul Processing Unit (C, U, S, & M Plane)' which includes Ethernet eCPRI, Beamforming, IEEE 1588 - PTP, Security, Compression/Decompression, Optical, and SyncE blocks. It connects via a Packet Interface to the 'Digital Processing Unit' in the center. The Digital Processing Unit contains DL/UL Processing, IQ Decompression, Compression/Decompression, Layer Mapping, Precoding, Low PDU, FFT/IFFT, CP Addition/Removal, and Framer/Deframer blocks. It connects via a Digital (IQ) Interface to the 'RF Processing Unit' on the right. The RF Processing Unit consists of four 'RF Transceiver Unit' blocks (labeled 1 to 4), each containing a DAC, DAC, DAC, and DAC. These connect via an RF Interface to the 'RF Frontend Unit' and finally to the 'Antenna'. An 'Antenna Calibration' block is shown at the top right. An 'Optional' section shows a 'mMIMO Antenna Array' with a grid of elements labeled 1 to 192. A 'Synchronization/Timing' block is at the bottom left, and a 'Power supply' block is at the bottom center.](2fc219629c9abf3dcdd8eed9f3e62061_img.jpg) + +Figure 2.5.2-1 mMIMO O-RU7-2x hardware reference design architecture example of 32T32R. The diagram shows a block diagram of the hardware architecture. On the left is the 'O-RAN Fronthaul Processing Unit (C, U, S, & M Plane)' which includes Ethernet eCPRI, Beamforming, IEEE 1588 - PTP, Security, Compression/Decompression, Optical, and SyncE blocks. It connects via a Packet Interface to the 'Digital Processing Unit' in the center. The Digital Processing Unit contains DL/UL Processing, IQ Decompression, Compression/Decompression, Layer Mapping, Precoding, Low PDU, FFT/IFFT, CP Addition/Removal, and Framer/Deframer blocks. It connects via a Digital (IQ) Interface to the 'RF Processing Unit' on the right. The RF Processing Unit consists of four 'RF Transceiver Unit' blocks (labeled 1 to 4), each containing a DAC, DAC, DAC, and DAC. These connect via an RF Interface to the 'RF Frontend Unit' and finally to the 'Antenna'. An 'Antenna Calibration' block is shown at the top right. An 'Optional' section shows a 'mMIMO Antenna Array' with a grid of elements labeled 1 to 192. A 'Synchronization/Timing' block is at the bottom left, and a 'Power supply' block is at the bottom center. + +**Figure 2.5.2-1 mMIMO O-RU<sub>7-2x</sub> hardware reference design architecture example of 32T32R** + +![Figure 2.5.2-2 mMIMO O-RU7-2x hardware reference design architecture example of 64T64R. The diagram shows a block architecture for a massive MIMO O-RU. It includes an O-RAN Fronthaul Processing Unit (C, U, S, & M Plane) connected to a Digital Processing Unit (DPU) via a Packet Interface. The DPU is connected to an RF Processing Unit (RPU) via a Digital IQ Interface. The RPU consists of multiple RF Transceiver Units (RTU) connected to an RF Frontend Unit (RFU), which is connected to an Antenna. The Antenna is connected to an mMIMO Antenna Array. The diagram also shows an optional mMIMO Antenna Array. The architecture is powered by a Power supply and synchronized by a Synchronization/Timing unit.](9e184c620ad8cd561b475de0ca1d42df_img.jpg) + +Figure 2.5.2-2 mMIMO O-RU7-2x hardware reference design architecture example of 64T64R. The diagram shows a block architecture for a massive MIMO O-RU. It includes an O-RAN Fronthaul Processing Unit (C, U, S, & M Plane) connected to a Digital Processing Unit (DPU) via a Packet Interface. The DPU is connected to an RF Processing Unit (RPU) via a Digital IQ Interface. The RPU consists of multiple RF Transceiver Units (RTU) connected to an RF Frontend Unit (RFU), which is connected to an Antenna. The Antenna is connected to an mMIMO Antenna Array. The diagram also shows an optional mMIMO Antenna Array. The architecture is powered by a Power supply and synchronized by a Synchronization/Timing unit. + +**Figure 2.5.2-2 mMIMO O-RU<sub>7-2x</sub> hardware reference design architecture example of 64T64R** + +## 2.5.2.1 O-RAN Fronthaul Processing Unit + +<<< This is left blank for the future contributions >>> + +## 2.5.2.2 Digital Processing Unit + +A Digital processing unit (DPU) architecture example of massive MIMO O-RU<sub>7-2x</sub> is shown in Figure 2.5.2-3 and a detailed description of the same is discussed in Sections 2.5.1 and 2.5.2. The DPU processes the packets from O-RAN fronthaul processing unit through the packet interface and feeds the data/control mapped RF output signals to the RF frontend unit through the RF interface to amplify the RF signals according to the output power requirement of the signal chain. These are subsequently fed to the antenna thereby the signals can be received by the user equipment, e.g., mobile subscriber terminal, home CPE, Wi-Fi device etc... + +The massive MIMO baseband processing requirements are largely based on the antenna data rate, Instantaneous/occupied bandwidth, number of transceiver chains, number of layers and component carriers and so on. Hence, the massive MIMO digital processing unit need to have one or more i.e., N number of digital front-end units to cater to the necessary baseband signal processing as shown in Figure 2.5.2-6 where an example implementation of the Digital Processing Unit is exposed; other implementations are not precluded. + +The digital processing unit consists of the processing system and FPGA/ASIC blocks, where the later one handles the functions like compression/decompression, layer mapping, beamforming matrix generation/decoding, FFT/IFFT, CP removal/insertion, channel filtering, and many more. Apart from these, the digital processing unit performs PRACH, and SRS associated functions. Some of the digital processing + +units may also handle the RF transceiver functions like channel DUC/DDC, CFR, DPD, and DAC/ADC along with associated digital serial interfaces. + +![Figure 2.5.2-3 mMIMO O-RU7-2x Digital processing unit architecture example. The diagram shows the internal architecture of a Digital Processing Unit (DFE #1 to DFE #N). It includes a Packet Interface, IQ Decompression, Layer Mapping, Beamforming Matrix, FFT, CP Insertion, Channel Filter, RF Transceiver, DAC, CR, DPD, and ADC blocks. The unit is connected to an O-RAN Fronthaul Processing Unit via an Optical Interface, and to an RF Frontend Unit via an RF Interface. An optional Antenna Panel is also shown. The architecture is supported by Synchronization/Timing and Power supply inputs.](edd8a810bc5367f11a90919ed8584a0c_img.jpg) + +Figure 2.5.2-3 mMIMO O-RU7-2x Digital processing unit architecture example. The diagram shows the internal architecture of a Digital Processing Unit (DFE #1 to DFE #N). It includes a Packet Interface, IQ Decompression, Layer Mapping, Beamforming Matrix, FFT, CP Insertion, Channel Filter, RF Transceiver, DAC, CR, DPD, and ADC blocks. The unit is connected to an O-RAN Fronthaul Processing Unit via an Optical Interface, and to an RF Frontend Unit via an RF Interface. An optional Antenna Panel is also shown. The architecture is supported by Synchronization/Timing and Power supply inputs. + +**Figure 2.5.2-3 mMIMO O-RU<sub>7-2x</sub> Digital processing unit architecture example** + +## 2.5.2.3 RF Processing Unit + +<<< This is left blank for the future contributions>>> + +### 2.5.2.3.1 RF Transceiver Unit + +<<< This is left blank for the future contributions>>> + +### 2.5.2.3.2 RF Front End Unit + +In general, the transmitter chain of mMIMO RF front end unit consists of balun, variable gain amplifier or step attenuator, amplifier stage (power amplifier, driver amplifier (optional), and pre-driver amplifier (optional)), circulator, and the filter (can be cavity or ceramic filters) as shown in Figure 2.5.2-4 and Figure 2.5.2-5 for 32T32R and 64T64R configurations, respectively. Similarly, the receiver chain consists of the low noise amplifier stage and band pass filter. The low noise amplifier stage consists of one or more low noise amplifiers either in normal or bypass mode depending on the received power level and the corresponding amplification requirement. + +The Digital to analog converter (DAC) output (Downlink RF signal) of the RF transceiver unit is fed to the respective transmitter chain for the amplification and subsequently fed to the antenna. Similarly, the receiver chain (Uplink signal) output from the antenna is fed to the respective analog to digital convertor input of the RF transceiver unit after amplification by the low noise amplifier stage and filtering. + +The number of RF transceiver units is decided based on the number of DAC outputs/ADC inputs that can be handled by the single unit. As an example, in Figure 2.5.2-4, for 32T32R configuration, four RF transceiver units are present, where each has eight ADC/DAC ports. Subsequently, thirty-two RF front end line-ups are + +connected to the respective DAC output of RF transceiver unit in the case of the transmitter chain and ADC input of RF transceiver in the case of receiver chain as shown in Figure 2.5.2-4. + +![Figure 2.5.2-4 mMIMO O-RU7-2x RF front end architecture example of 32T32R. The diagram shows a Digital Processing Unit (Baseband Chip) connected via a Digital (I/Q) Interface to an RF Processing Unit. The RF Processing Unit contains multiple RF Transceiver Units (Transceiver 1 to Transceiver 4) and RF Frontend Units. Each transceiver unit has a Serial Interface connected to the baseband chip, with DACs for transmission and ADCs for reception. The RF Frontend Units include OBA/VOA, Driver, PA, Circulator, and SPF blocks, connected to an mMIMO Antenna Array.](b2d0a4336d004005ec3188194666be40_img.jpg) + +The diagram illustrates the RF front end architecture for a 32T32R mMIMO O-RU. On the left, a 'Digital Processing Unit (Baseband Chip)' is connected to an 'RF Processing Unit' via a 'Digital (I/Q) Interface'. The baseband chip also has a 'Packet Interface' to a 'To/From O-RAN Fronthaul processing unit'. The RF Processing Unit is divided into two main sections: 'RF Transceiver Unit' and 'RF Frontend Unit'. The RF Transceiver Unit contains multiple transceivers (Transceiver 1 to Transceiver 4), each with a 'Serial Interface' connected to the baseband chip. Each transceiver has a transmitter chain (DUC, CFR, DPD, DAC1) and a receiver chain (ADC1, DDC). The RF Frontend Unit contains multiple RF front ends, each connected to a transceiver. Each RF front end includes an OBA/VOA, Driver, PA, Circulator, and SPF block. The RF front ends are connected to an 'mMIMO Antenna Array'. + +Figure 2.5.2-4 mMIMO O-RU7-2x RF front end architecture example of 32T32R. The diagram shows a Digital Processing Unit (Baseband Chip) connected via a Digital (I/Q) Interface to an RF Processing Unit. The RF Processing Unit contains multiple RF Transceiver Units (Transceiver 1 to Transceiver 4) and RF Frontend Units. Each transceiver unit has a Serial Interface connected to the baseband chip, with DACs for transmission and ADCs for reception. The RF Frontend Units include OBA/VOA, Driver, PA, Circulator, and SPF blocks, connected to an mMIMO Antenna Array. + +**Figure 2.5.2-4 mMIMO O-RU<sub>7-2x</sub> RF front end architecture example of 32T32R** + +Like the 32T32R, as an example, in Figure 2.5.2-5, for 64T64R configuration, eight RF transceiver units are present, where each has eight ADC/DAC ports. Subsequently, sixty-four RF front end line-ups are connected to the respective DAC output of RF transceiver unit in the case of the transmitter chain and ADC input of RF transceiver in the case of receiver chain as shown in Figure 2.5.2-5. + +![Figure 2.5.2-5 mMIMO O-RU7-2x RF front end architecture example of 64T64R. The diagram shows a Digital Processing Unit (Baseband Chip) connected via a Digital (I/Q) Interface to an RF Processing Unit. The RF Processing Unit contains 8 Transceiver Units (Transceiver 1 to Transceiver 8). Each Transceiver Unit has a Serial Interface connected to the Digital Processing Unit. The Serial Interface includes DUC, CFR, DPC, DAC1, DDC, and ADC1 blocks. The RF Transceiver Unit also includes a BALUN, DBA/VGA, Driver, PA, and Circulator. The RF Frontend Unit includes a BALUN, BPF, LNA, and PA. The RF Processing Unit is connected to an mMIMO Antenna Array.](bb2c61be3025d1ddb64910b1527a2a1e_img.jpg) + +Figure 2.5.2-5 mMIMO O-RU7-2x RF front end architecture example of 64T64R. The diagram shows a Digital Processing Unit (Baseband Chip) connected via a Digital (I/Q) Interface to an RF Processing Unit. The RF Processing Unit contains 8 Transceiver Units (Transceiver 1 to Transceiver 8). Each Transceiver Unit has a Serial Interface connected to the Digital Processing Unit. The Serial Interface includes DUC, CFR, DPC, DAC1, DDC, and ADC1 blocks. The RF Transceiver Unit also includes a BALUN, DBA/VGA, Driver, PA, and Circulator. The RF Frontend Unit includes a BALUN, BPF, LNA, and PA. The RF Processing Unit is connected to an mMIMO Antenna Array. + +Figure 2.5.2-5 mMIMO O-RU<sub>7-2x</sub> RF front end architecture example of 64T64R + +### 2.5.2.4 mMIMO Antenna/Phased array reference design + +A mMIMO antenna array reference architecture examples for 32T32R and 64T64R are shown in Figure 2.5.2-6 and Figure 2.5.2-7 respectively. In Figure 2.5.2-6, two transceiver chains are connected to the one sub array with six dual polarized elements. i.e., one transceiver chain is connected to one polarization (vertical) sub array and another one with another polarization (horizontal) sub array. Similarly, each of the transceiver chains are connected to one of the two polarizations of sub arrays. The overall antenna element arrangement of an array for 32T32R is shown in Figure 2.5.2-6 + +In Figure 2.5.2-6 mMIMO O-RU<sub>7-2x</sub> antenna array architecture example of 32T32R the parameters like transmitted power per chain, antenna element gain, total antenna array gain, and finally the EIRP are shown/mentioned at the respective part of the architecture for 32T32R configuration. + +The details of parameters are listed below along with the respective equations. + +**Total output power of the mMIMO Radio Unit in dBm, $P_T = 10 \log_{10} (P_T, W) + 30$ , dBm,** + +**Transmit power per chain, $P_c = \frac{\text{Total output power of the mMIMO Radio Unit } (P_T), (W)}{\text{No of transceiver chains}}$** + +**Transmit power per chain in dBm, $P_c = 10 \log_{10} (P_c, W) + 30$ , dBm,** + +**Antenna element gain = $G_E$ , dBi,** + +- 1 Total antenna array gain = $G_T$ , dBi, +- 2 Total antenna array absolute gain, $G_T, abs = G_{E, abs} \times total\ no\ of\ elements$ , +- 3 Total antenna gain in dBi, $G_T = 10 \log_{10} (G_T, abs)$ , dBi, +- 4 EIRP = $P_T$ , dBm + $G_T$ , dBi. + +![Figure 2.5.2-6 mMIMO O-RU7-2x antenna array architecture example of 32T32R. The diagram shows a block diagram of the RF chain. On the left, there are two input paths labeled 'PA' and 'LNA' with power levels 'Pc W (Pc dBm)'. These feed into a central processing block. The output of this block is a vertical array of 12 elements, each labeled '1,2'. This array is connected to a larger 32T32R antenna array, which is a 4x8 grid of elements. Each element in the grid is labeled with a number from 1 to 32. The total gain of the antenna array is labeled 'GT dBi'. The output of the antenna array is a fan-shaped beam, labeled 'EIRP, dBm (PT dBm + GT dBi)'.](0e9f68924ae66af5ddf97c4f7e9d6e46_img.jpg) + +Figure 2.5.2-6 mMIMO O-RU7-2x antenna array architecture example of 32T32R. The diagram shows a block diagram of the RF chain. On the left, there are two input paths labeled 'PA' and 'LNA' with power levels 'Pc W (Pc dBm)'. These feed into a central processing block. The output of this block is a vertical array of 12 elements, each labeled '1,2'. This array is connected to a larger 32T32R antenna array, which is a 4x8 grid of elements. Each element in the grid is labeled with a number from 1 to 32. The total gain of the antenna array is labeled 'GT dBi'. The output of the antenna array is a fan-shaped beam, labeled 'EIRP, dBm (PT dBm + GT dBi)'. + +5 + +6 **Figure 2.5.2-6 mMIMO O-RU<sub>7-2x</sub> antenna array architecture example of 32T32R** + +7 An example calculation for the 32T32R mMIMO in the entire RF chain till the antenna, i.e., EIRP is detailed + +8 out below. + +9 **Example calculation for 32T32R mMIMO configuration:** + +10 **Specifications:** + +11 **No of transceiver chains = 32 i.e., 32T32R,** + +12 **Total output power, $P_T = 320$ W,** + +13 **EIRP = 79 dBm,** + +14 **Total number of antenna elements = 96 (dual linear polarized, hence total number of elements would be** + +15 **192),** + +16 **Number of elements in a subarray = 6.** + +17 **Calculation:** + +18 **Total output power $P_T = 320$ W,** + +19 **Transmit power per chain, $P_c = \frac{320}{32} = 10$ W,** + +20 **Total output power of the mMIMO Radio Unit in dBm, $P_T = 10 \log_{10} (320, W) + 30 = 55.05$ dBm,** + +**Transmit power per chain in dBm, $P_c = 10 \log_{10} (10 \text{ W}) + 30 \text{ dBm} = 40 \text{ dBm}$ ,** + +**Antenna element gain, $G_E = 4 \text{ dBi}$ ,** + +**Final antenna array absolute gain, $G_T, \text{abs} = 2.51 \times 96 = 240.96$ ,** + +**Antenna subarray gain in dBi, $G_T = 23.82 \text{ dBi}$ ,** + +**EIRP = 55.05 + 23.82 = 78.87 dBm,** + +Similarly, the parameters like transmitted power per chain, antenna element gain, sub array antenna gain, total antenna array gain, and finally the EIRP are shown/mentioned at the respective part of the architecture in Figure 2.5.2-7 mMIMO O-RU7-2x antenna array architecture example of 64T64R. + +![Figure 2.5.2-7 mMIMO O-RU7-2x antenna array architecture example of 64T64R. The diagram shows a block diagram of the RF chain and a detailed view of the antenna array. The RF chain includes a PA (Power Amplifier) and an LNA (Low Noise Amplifier) block, with input and output power labels P_c W (P_c dBm). The antenna array is a 64T64R 192AE configuration, showing a grid of 192 elements (16x12) with individual element gains G_E dBi and total array gain G_T dBi. The EIRP (Equivalent Isotropically Radiated Power) is shown as a fan beam with the label EIRP, dBm (P_T dBm + G_T dBi).](145bbb0f38ed95f46b5fb862dac1e97a_img.jpg) + +Figure 2.5.2-7 mMIMO O-RU7-2x antenna array architecture example of 64T64R. The diagram shows a block diagram of the RF chain and a detailed view of the antenna array. The RF chain includes a PA (Power Amplifier) and an LNA (Low Noise Amplifier) block, with input and output power labels P\_c W (P\_c dBm). The antenna array is a 64T64R 192AE configuration, showing a grid of 192 elements (16x12) with individual element gains G\_E dBi and total array gain G\_T dBi. The EIRP (Equivalent Isotropically Radiated Power) is shown as a fan beam with the label EIRP, dBm (P\_T dBm + G\_T dBi). + +**Figure 2.5.2-7 mMIMO O-RU<sub>7-2x</sub> antenna array architecture example of 64T64R** + +Also, the example calculation for the entire RF chain till antenna for 64T64R is presented below + +**Example calculation 64T64R mMIMO configuration:** + +**Specifications:** + +**No of transceiver chains = 64 i.e., 64T64R,** + +**Total output power, $P_T = 320 \text{ W}$ ,** + +**EIRP = 79 dBm,** + +**Total number of antenna elements = 96 (dual linear polarized, hence total number of elements would be 192),** + +**Number of elements in a subarray = 3.** + +**Calculation:** + +**Total output power, $P_T = 320$ W,** + +**Transmit power per chain, $P_c = \frac{320}{64} = 5$ W,** + +**Total output power of the mMIMO Radio Unit in dBm, $P_T = 10 \log_{10} (320, W) + 30 = 55.05$ dBm,** + +**Transmit power per chain in dBm, $P_c = 10 \log_{10} (5 W) + 30$ dBm = 37 dBm,** + +**Antenna element gain, $G_E = 4$ dBi,** + +**Final antenna array absolute gain, $G_T, \text{abs} = 2.51 \times 96 = 240.96,$** + +**Antenna subarray gain in dBi, $G_T = 23.82$ dBi,** + +**EIRP = 55.05 + 23.82 = 78.87 dBm.** + +The simulation model of mMIMO antenna array with 192 reflector backed elements and the 32T32R mMIMO O-RU<sub>7-2x</sub> antenna array prototype is shown in Figure 2.5.2-8 mMIMO antenna array view (a) simulation model of 192 reflector backed antenna element array only and (b) 32T32R mMIMO O-RU<sub>7-2x</sub> Antenna array prototype [14], respectively. + +![Figure 2.5.2-8 mMIMO antenna array view. (a) Simulation model of 192 reflector backed antenna element array only, showing a 12x16 grid of elements. (b) 32T32R mMIMO O-RU7-2x Antenna array prototype, showing a physical prototype with a 12x16 grid of elements and a metal frame.](604aa18f8cfa97dff3b5f56fd72c4079_img.jpg) + +Figure 2.5.2-8 mMIMO antenna array view. (a) Simulation model of 192 reflector backed antenna element array only, showing a 12x16 grid of elements. (b) 32T32R mMIMO O-RU7-2x Antenna array prototype, showing a physical prototype with a 12x16 grid of elements and a metal frame. + +**Figure 2.5.2-8 mMIMO antenna array view (a) simulation model of 192 reflector backed antenna element array only and (b) 32T32R mMIMO O-RU<sub>7-2x</sub> Antenna array prototype [14]** + +## 2.5.3 Mechanical + +Various mechanical designs are possible for the mMIMO O-RU<sub>7-2x</sub>. As an example, the isometric view of mMIMO O-RU<sub>7-2x</sub> is shown in Figure 2.5.3-1 Mechanical enclosure, where the heat sink fins and Radome are attached/placed at the backside and frontside of the radio unit, respectively. The heatsink fins are used to dissipate the heat that is generated inside the radio unit to the backward direction. The Radome is a RF transparent cover, and it acts as a shield and protect the antenna and radio unit from the environment while allowing the radiated waves from an antenna to the free space environment. + +![Isometric view of the mMIMO O-RU7-2x mechanical enclosure, showing a white rectangular unit with a heat sink fin array on the backside and a radome on the frontside.](3b74b918f90cb274b2c4229c01d6794f_img.jpg) + +Isometric view of the mMIMO O-RU7-2x mechanical enclosure, showing a white rectangular unit with a heat sink fin array on the backside and a radome on the frontside. + +**Figure 2.5.3-1 Mechanical enclosure** + +Figure 2.5.3-2 Exploded views of mechanical architecture/stacking examples (a) design #1 and (b) design #2 (a) and (b) show the exploded view of two mechanical design examples along with optional stacking. These figures illustrate the stacking of heat sink including vapor chamber or heat pipe for the heat dissipation, RF board, digital board, cavity filter, RF shield, antenna elements, and finally the top cover (Radome). These designs basically show the single stack up approach where all the RF chains, digital, and power section are placed in same heatsink surface area to make the design thermally stable one with few respective challenges. Different sections can be divided into multiple boards to reduce the complexity of routing as well as testing. Vapor chamber or heat pipe solution will help to mitigate this problem. If required, cut-outs can be given in the shield to provide heat sink area to major heat dissipating components. + +Figure 2.5.3-2 Exploded views of mechanical architecture/stacking examples (a) design #1 and (b) design #2 shows the mechanical stacking/design where the components/peripherals placed vertically on the RF and digital boards, which results in large height along with moderate width. Accordingly, the cavity filter is + +designed in accordance with the respective connector position and RF shield also placed vertically to act as an isolator between the radiations coming from the RF board and antenna, in other words, it blocks the signals from RF board to antenna and vice versa. Antenna elements are placed as shown in Figure 2.5.3-2 Exploded views of mechanical architecture/stacking examples (a) design #1 and (b) design #2(a) and (b). + +Figure 2.5.3-2 Exploded views of mechanical architecture/stacking examples (a) design #1 and (b) design #2 the stacking option where components/peripherals of RF and digital boards are placed horizontally, and this results in the overall radio unit to have a broader width and moderate height. Here the RF shield and cavity filters are placed in accordance with the layout of RF and digital boards. + +![Exploded view (a) of mechanical architecture/stacking example design #1. The diagram shows a stack of components from left to right: Top cover or Radome, Vapor Chamber or heat pipe solution (integrated on the back side of RF + Digital board for heat distribution), RF board, Digital board, Cavity filter, RF Shield, and Antenna elements.](cc1b1b9ed0e7d7dfb0655fe914214205_img.jpg) + +Exploded view (a) of mechanical architecture/stacking example design #1. The diagram shows a stack of components from left to right: Top cover or Radome, Vapor Chamber or heat pipe solution (integrated on the back side of RF + Digital board for heat distribution), RF board, Digital board, Cavity filter, RF Shield, and Antenna elements. + +(a) + +![Exploded view (b) of mechanical architecture/stacking example design #2. The diagram shows a stack of components from left to right: Top cover or Radome, Vapor Chamber or heat pipe solution (integrated on the back side of RF + Digital board for heat distribution), RF + Digital board, Cavity filter, RF Shield, and Antenna elements.](786e969bdcec853366e7f08b63f6e656_img.jpg) + +Exploded view (b) of mechanical architecture/stacking example design #2. The diagram shows a stack of components from left to right: Top cover or Radome, Vapor Chamber or heat pipe solution (integrated on the back side of RF + Digital board for heat distribution), RF + Digital board, Cavity filter, RF Shield, and Antenna elements. + +Exploded +view + +(b) + +**Figure 2.5.3-2 Exploded views of mechanical architecture/stacking examples (a) design #1 and (b) design #2** + +## 2.6 FHGW Hardware Reference Design + +The O-RAN Hardware Reference Design Specification for Fronthaul Gateway v2.0 (if required by design) can be found here: <https://orandownloadsweb.azurewebsites.net/specifications> + +The fronthaul gateway can be used to terminate O-RAN fronthaul user, control, synchronization, and management planes for option 7-2x and to translate the signals to and from several CPRI interfaces (option 8). It can further multiplex or demultiplex option 7-2x fronthaul signals to or from several O-RUs. This version of the specification only supports option 7-2x to option 8 conversion and vice versa in addition to the transport of other traffic streams. + +## Annex 1: Parts Reference List + +According to WG7 scope and charter, component selection, for example implementation of white box hardware is allowed for WG7 but would not be mandatory in any Specification. + +### 1.1 Supermicro O-DU: + +| No. | Supermicro Part Number | Description | +|-----|------------------------|---------------------------------------------------------------------------------------------| +| 1 | SYS-111E-FDWTR | Intel Xeon Gen 4 (Sapphire Rapids) 1U server, DC power | +| 2 | P4X-SPR5411N-SRMGY-MCC | Intel CPU SPR-SP 5411N 24C (1.9G, 2.1G) 165W | +| 3 | MEM-DR516L-HL01-ER48 | 16GB DDR5 4800 ECC RDIMM (x 8) 256MB total | +| 4 | HDS-I2T0-SSDSC2KG480GZ | Intel D3 S4620 480GB SATA 6Gb/s 3D TLC 2.5" 7.0mm< 3DWPD (x2 total in RAID1) | +| 5 | AOM-TPM-9670V-S-O | Trusted Platform Module 2.0 | +| 6 | AOC-P425G410G8-ZR | Silicom 25/10 Gigabit Ethernet Grand Master TimeSync Server Adapter (includes transceivers) | +| 7 | AOC-P3IMB1-M-P2 | Silicom eASIC ACC100 FEC Accelerator | +| | | | + +### 1.2 ADI Based O-RU 4T4R: + +| No. | Item Name | Description | +|-----|----------------------|------------------------------------------------------------------------| +| 1 | ADP196ACBZ-R7 | 5V, 3A Logic Controlled High-Side Power Switch | +| 2 | LTC7150SEY#PBF | 20V, 20A Synchronous Ste-Down Regulator | +| 3 | ADRV9029 | Integrated, Quad RF Transceiver with Observation Path and DPD/CFR | +| 4 | ADP223ACPZ-R7 | Dual, 300 mA Adjustable Output, Low Noise, High PSRR Voltage Regulator | +| 5 | LTC4217IDHC#PBF | 2A Integrated Hot Swap Controller | +| 6 | ADCLK846BCPZ-REEL7 | 1.8V, 6 LVDS/12 CMOS Output Low Power Clock Fanout Buffer | +| 7 | AD9545BCPZ | IEEE 1588 V2 and 1 pps Synchronizer and Adaptive Clock Translator | +| 8 | ADRF5545A | Dual-Channel 2.4 to 4.2 GHz Receiver Front End | +| 9 | LTC3315AIV#TRMPBF | Dual 5V, 2A Synchronous Step-Down DC/DCs | +| 10 | LTC3634EUFD#PBF | 15V Dual 3A Monolithic Step-Down Regulator for DDR Power | +| 11 | LTC2928IUHF#BPF | Multichannel Power Supply Sequencer and Supervisor | +| 12 | ADP5054ACPZ-R7 | Quad Buck Regulator Integrated Power Solution | +| 13 | AD9576BPZ | Dual PLL, Asynchronous Clock Generator | +| 14 | LT1389ACS8-1.25#PBF | Nanopower Precision Shunt Voltage Reference | +| 15 | Intel® Arria® 10 SoC | Intel® Arria® 10 SoC 1AS048F35 | +| 16 | MAX1619MEE | Temp Sensor with Dual-Alarm Outputs and PMBus | + +## 1.3 ADI Based O-RU 8T8R: + +| No. | Item Name | Description | +|-----|------------------------|------------------------------------------------------------------------------------------| +| 1 | AD9576BPZ | Dual PLL, Asynchronous Clock Generator | +| 2 | AD9545BCPZ | IEEE 1588 V2 and 1 pps Synchronizer and Adaptive Clock Translator | +| 5 | MAX6581TG9A+ | $\pm 1^{\circ}\text{C}$ Accurate 8-Channel Temperature Sensor | +| 6 | DS1339C-33# | I <sup>2</sup> C Serial Real-Time Clock | +| 7 | ADIN1300CCPZ | Robust, Industrial, Low Latency and Low Power 10 Mbps, 100 Mbps, and 1 Gbps Ethernet PHY | +| 8 | ADRV904x | 8T8R 400MHz RF Transceiver, Integrated Observation Paths with DFE | +| 9 | Intel® AGFB014R24B212V | Intel® Agilex® AGF014 | +| 10 | LTC2980 | PMBus Power System Manager | +| 12 | LTC4251BIS6-1#TRMPBF | Negative Voltage Hot Swap Controllers in SOT-23 | +| 13 | LTC3888-1 | Dual Loop 8-Phase Step-Down DC/DC Controller with Digital Power System Management | +| 14 | LTC8625SP-1 | 18V/8A Step-Down Silent Switcher 3 with Ultralow Noise | +| 15 | LT8627SPJV#PBF | 18V/16A Step-Down Silent Switcher 3 with Ultralow Noise | +| 16 | LTC3315AJV#WTRPBF | Dual 5V, 2A Synchronous Step-Down DC/DCs in Tiny LQFN and WLCSP | +| 17 | LTC3636EUFD#TRPBF | Dual Channel 6A, 20V Monolithic Synchronous Step-Down Regulator | +| 18 | LTC3618EUF#PBF | Dual 4MHz, $\pm 3\text{A}$ Synchronous Buck Converter for DDR Termination | +| 19 | ADCLK846BCPZ-REEL7 | 1.8V, 6 LVDS/12 CMOS Output Low Power Clock Fanout Buffer | + +## History + +| Date | Revision | Description | +|------------|----------|---------------------------------------------------------------------------------------------------------------------------------------| +| 2022/02/02 | v01.00 | Published as final version 01.00 | +| 2022/11/09 | v02.00 | Published as revision 02.00 (adds a new section for O-RU internal interfaces with updated diagrams and massive MIMO reference design) | +| 2022/02/16 | V03.00 | Published as revision 03.00 (updated section 2.2 O-DU spec and Annex 1.1) | \ No newline at end of file diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/012b7eed69b3f26856a38baaf7286c44_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/012b7eed69b3f26856a38baaf7286c44_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9b241b0d7a07442c82ae9e7124f1b98b78704524 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/012b7eed69b3f26856a38baaf7286c44_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5671f366999ae6105d9e28bd7e9b36492d91381b5350376b08625f6b2a92bb03 +size 34292 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/06a264d2791f02ac2ae673b0333fdb3e_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/06a264d2791f02ac2ae673b0333fdb3e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..61cc9ff68ebb99d8c4824f41f91fd84eaaff2dae --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/06a264d2791f02ac2ae673b0333fdb3e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7850dc7df66f8d99c953b2a38a285c9e2c61f70fc913c818760f5e63aa9d0bae +size 34051 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/0d3cbc0655057943f64042af4619ca8c_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/0d3cbc0655057943f64042af4619ca8c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..640f9014daadc158da50baab86cb0e7f6f4e7bc1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/0d3cbc0655057943f64042af4619ca8c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d1512efdec505d38b5422f37f8763f58a737e5c05f94eac28199af5e78b3e54d +size 39231 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/235455b69e6103354739088b5053458c_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/235455b69e6103354739088b5053458c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7dddcea803789b2e0cc00717bd7687c01ba31203 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/235455b69e6103354739088b5053458c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2189b47608d4bb82b7c0b6682cabd35dd7b27ac056fae8d166a7962c5636e2cf +size 45336 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/25842ee03b6480e1c3de9aad2bca05f7_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/25842ee03b6480e1c3de9aad2bca05f7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a708192e2bdafbd82b84be64033d84583da6d4e1 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/25842ee03b6480e1c3de9aad2bca05f7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7dca701351dc97967c247677fec3fcc62200e3a0cbd37e6bfc892861a2d31f50 +size 42440 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/2937159d96d363480cd67ed09fe295b6_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/2937159d96d363480cd67ed09fe295b6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4384ef17a3468429265e48e8fea96aecdd62d368 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/2937159d96d363480cd67ed09fe295b6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0c08c02bac3838e37ffd0d41ece3fdbd89701078dc794d679f40e5fd58cf3f0c +size 4567 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/4ac919749c534a312f4bb025db592bd8_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/4ac919749c534a312f4bb025db592bd8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9031d399211b47eafefcd995c5bc4dd881bb8f76 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/4ac919749c534a312f4bb025db592bd8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4bc63e572e0f1ab6ba5f63e4d06083241da0c2eaf6979af40e570f2103880121 +size 32662 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/6728d29c1dbbc492e6861104416d980a_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/6728d29c1dbbc492e6861104416d980a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..344d32cde4f8682b794266c02c72c36cace4e171 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/6728d29c1dbbc492e6861104416d980a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:46915f19929a62761cb2423e721633697d719a8cc837beade9e21c973cd2d819 +size 15779 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/7281f169c2515fdfd1455dec7a00a5f0_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/7281f169c2515fdfd1455dec7a00a5f0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..200f8566c0bafe6b560b6d5ff58490bbd861e32c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/7281f169c2515fdfd1455dec7a00a5f0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:af800aa1e4771d296c27cd666a633516f074d3abe57a974bab2afe7ee33e65e1 +size 4548 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/73965d5030c14fdb6b4ae04d5df300a7_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/73965d5030c14fdb6b4ae04d5df300a7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..70b0fa89b1f89c5e60a07ee64a4c92a0738bbbbe --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/73965d5030c14fdb6b4ae04d5df300a7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9743bb2f82d11b06cc018f59adf993618912e73995dc477b532714fb8be06ead +size 4549 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/88e3a13e8b196b643c3763f04e28c13a_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/88e3a13e8b196b643c3763f04e28c13a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2c75c3f9521e03701930028d5cb374b00dc5d23c --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/88e3a13e8b196b643c3763f04e28c13a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2934a1669f5eca55cc6bc59bedb4ead90e3be4530c0ba53c13beda8b4ffa9a37 +size 4547 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/9e90b853d9e78abe6038aee8acc90e44_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/9e90b853d9e78abe6038aee8acc90e44_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ebd464cded4298456cc2308ccacf7677de42749e --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/9e90b853d9e78abe6038aee8acc90e44_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a4d4381a90cc29dc610fbdd561b09eb70ca4122e47cd5f2276e72b487797b20d +size 4595 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/acb97b536b4d71f3118896c59b5e89ec_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/acb97b536b4d71f3118896c59b5e89ec_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5d58304e07eb12d5b53012a917f78f2316a58f85 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/acb97b536b4d71f3118896c59b5e89ec_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a2573d350a883f1b490e6e5232fa3fddf21ce45128fb837668acdb0d45b3d873 +size 4597 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/b16e9f01147d3840d718e6b10b549ab7_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/b16e9f01147d3840d718e6b10b549ab7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..98c110778f0430881912f4d09b796a37b2ef55ad --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/b16e9f01147d3840d718e6b10b549ab7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4817881452fdf34996a5a97b25d4f2e82d76cd522e47a303f15ece8b8149b402 +size 4542 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/bcec904190f3af44ebd18add77f587b2_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/bcec904190f3af44ebd18add77f587b2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0c732b711d6d14a1340b306d26f7c4eff22fefa0 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/bcec904190f3af44ebd18add77f587b2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09f052484c2db82d29f0c509780f944b39c1e1b3e400329a9659ae0304cc2c32 +size 35873 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/c01ea2b4af3438b84958476e4f1ade46_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/c01ea2b4af3438b84958476e4f1ade46_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..97f7e4896177207621776a735a249980adc3e170 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/c01ea2b4af3438b84958476e4f1ade46_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a73b686119c46cea5c506a2a5fbabcf84a7f613d3d0afd7a073ddddefd2f8a6c +size 24113 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/c421e42fccfddef62ef4953e8f5e5cff_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/c421e42fccfddef62ef4953e8f5e5cff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..60ebe8efd9897b5ba5ca9ee64dbf8a5caedace1e --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/c421e42fccfddef62ef4953e8f5e5cff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f432b8681ab575e52e84020c226fcbb70fb7c379c608e802a6ae9e229e86bc23 +size 56193 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/d04cc0deb37ae2ff8a8f3a1d0d7a302d_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/d04cc0deb37ae2ff8a8f3a1d0d7a302d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2a59f0ee9c8a121d3a4fb844a1b0555c2606b792 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/d04cc0deb37ae2ff8a8f3a1d0d7a302d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c71fc1dee26ef182bdd968f2f7ae20077b7cbc06c9e32f85e002f0c23b926e7c +size 4581 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/e1a2465ddf14f51e655c7608e2f633a2_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/e1a2465ddf14f51e655c7608e2f633a2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3b585e3d5f7cabc9d0013bf36cc40747abdd393f --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/e1a2465ddf14f51e655c7608e2f633a2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d5f9c4320b0e88e1bee20952d91a46837c368c31e4e486d3faaa7a61c030ee54 +size 25878 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/ec09a7483fbd396c1a944d050c226e90_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/ec09a7483fbd396c1a944d050c226e90_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b553826ce1e10b40008debf1aa7e81facc5e9aee --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/ec09a7483fbd396c1a944d050c226e90_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d5d4fb7b7380e202ef255ac1c27632d7025e0c8f0af1dc3ae7df1e501a128b1d +size 4544 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/ec5e7248434494681d254f4600de23ff_img.jpg b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/ec5e7248434494681d254f4600de23ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5ae881f6611f3b15c6734e259e9e9960bc1b50cb --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/ec5e7248434494681d254f4600de23ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:afb96aaaa2a4a6e6ab64ab3cae080c41e17a3561c4883777064526200421d579 +size 31507 diff --git a/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/raw.md b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..6379b0a129ad927665e154545020ab049f646820 --- /dev/null +++ b/marked/WG7/O-RAN.WG7.OMC-HAR.0-v01.00/raw.md @@ -0,0 +1,1048 @@ + + +# **O-RAN White Box Hardware Working Group Outdoor Micro Cell Hardware Architecture and Requirements (FR1) Specification** + +--- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN White Box Hardware Working Group Outdoor Micro Cell Hardware Architecture and Requirements (FR1) Specification** --- + +Copyright © 2021 by O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in the Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +# --- Revision History + +| Date | Revision | Author | Description | +|------------|----------|--------|-------------------------------| +| 2021.01.14 | v01.00 | WG7 | Final Version for Publication | + +# Contents + +| | | | +|----|-----------------------------------------------------------------------------------|----| +| 1 | Revision History..... | 2 | +| 2 | Chapter 1 Introductory Material..... | 6 | +| 3 | 1.1 Scope ..... | 6 | +| 4 | 1.2 References ..... | 6 | +| 5 | 1.3 Definitions and Abbreviations..... | 7 | +| 6 | 1.3.1 Definitions..... | 7 | +| 7 | 1.3.2 Abbreviations..... | 8 | +| 8 | Chapter 2 Deployment Scenarios and White Box Base Station Architecture..... | 11 | +| 9 | 2.1 Deployment Scenarios..... | 11 | +| 10 | 2.2 White Box Base Station Architecture..... | 11 | +| 11 | 2.2.1 Split RAN Architecture..... | 12 | +| 12 | 2.2.2 Integrated gNB-DU Architecture..... | 14 | +| 13 | Chapter 3 White Box Hardware Architecture ..... | 15 | +| 14 | 3.1 O-CU Hardware Architecture..... | 15 | +| 15 | 3.1.1 O-CU Architecture Diagram..... | 15 | +| 16 | 3.1.2 O-CU Functional Module Description..... | 15 | +| 17 | 3.1.3 O-CU Interfaces ..... | 16 | +| 18 | 3.2 O-DU <sub>7-2</sub> Hardware Architecture ..... | 16 | +| 19 | 3.2.1 O-DU <sub>7-2</sub> Architecture Diagram ..... | 16 | +| 20 | 3.2.2 O-DU <sub>7-2</sub> Functional Module Description ..... | 16 | +| 21 | 3.2.3 O-DU <sub>7-2</sub> Interfaces ..... | 18 | +| 22 | 3.3 O-DU <sub>6</sub> Hardware Architecture ..... | 19 | +| 23 | 3.4 O-DU <sub>8</sub> Hardware Architecture..... | 19 | +| 24 | 3.5 FHGW <sub>7-2</sub> - Option 7-2 to Option 7-2 Hardware Architecture..... | 19 | +| 25 | 3.6 FHGW <sub>6</sub> - Option 6 to Option 6 Hardware Architecture ..... | 19 | +| 26 | 3.7 FHGW <sub>7-2->8</sub> - Option 7-2 to Option 8 Hardware Architecture..... | 19 | +| 27 | 3.8 FHGW <sub>8</sub> - Option 8 to Option 8 Hardware Architecture ..... | 19 | +| 28 | 3.9 O-RU <sub>7-2</sub> Hardware Architecture..... | 19 | +| 29 | 3.9.1 O-RU <sub>7-2</sub> Architecture Diagram..... | 20 | +| 30 | 3.9.2 O-RU <sub>7-2</sub> Functional Module Description..... | 20 | +| 31 | 3.10 O-RU <sub>6</sub> Hardware Architecture..... | 21 | +| 32 | 3.11 O-RU <sub>8</sub> Hardware Architecture..... | 21 | +| 33 | 3.12 Integrated gNB-DU Hardware Architecture..... | 21 | +| 34 | Chapter 4 White Box Hardware Requirements ..... | 22 | +| 35 | 4.1 O-CU Requirements ..... | 22 | +| 36 | 4.1.1 O-CU Performance..... | 22 | +| 37 | 4.1.2 O-CU Interfaces ..... | 23 | +| 38 | 4.1.3 O-CU Environmental and EMC..... | 23 | + +| | | | | +|----|-------|-------------------------------------------------------------|----| +| 1 | 4.1.4 | O-CU Mechanical, Thermal and Power ..... | 24 | +| 2 | 4.2 | O-DU <sub>x</sub> Common Requirements ..... | 25 | +| 3 | 4.2.1 | O-DU <sub>x</sub> Performance ..... | 25 | +| 4 | 4.2.2 | O-DU <sub>x</sub> Interfaces..... | 26 | +| 5 | 4.2.3 | O-DU <sub>x</sub> Environmental and EMC ..... | 26 | +| 6 | 4.2.4 | O-DU <sub>x</sub> Mechanical, Thermal and Power ..... | 27 | +| 7 | 4.3 | O-DU <sub>x</sub> Split Option Specific Requirements ..... | 28 | +| 8 | 4.3.1 | O-DU <sub>7-2</sub> Specific Requirements ..... | 28 | +| 9 | 4.3.2 | O-DU <sub>6</sub> Specific Requirements ..... | 29 | +| 10 | 4.3.3 | O-DU <sub>8</sub> Specific Requirements ..... | 29 | +| 11 | 4.4 | O-RU <sub>x</sub> Common Requirements ..... | 29 | +| 12 | 4.4.1 | O-RU <sub>x</sub> Performance ..... | 29 | +| 13 | 4.4.2 | O-RU <sub>x</sub> Interfaces..... | 30 | +| 14 | 4.4.3 | O-RU <sub>x</sub> Environmental and EMC..... | 31 | +| 15 | 4.4.4 | O-RU <sub>x</sub> Mechanical, Thermal and Power..... | 31 | +| 16 | 4.5 | O-RU <sub>x</sub> Split Option Specific Requirements..... | 33 | +| 17 | 4.5.1 | O-RU <sub>7-2</sub> Specific Requirements ..... | 33 | +| 18 | 4.5.2 | O-RU <sub>6</sub> Specific Requirements ..... | 33 | +| 19 | 4.5.3 | O-RU <sub>8</sub> Specific Requirements ..... | 33 | +| 20 | 4.6 | FHGW <sub>x</sub> – Common Requirements ..... | 33 | +| 21 | 4.7 | FHGW <sub>x</sub> – Split Option Specific Requirements..... | 33 | +| 22 | 4.8 | Integrated gNB-DU Requirements ..... | 33 | +| 23 | | Annex ZZZ: O-RAN Adopter License Agreement ..... | 34 | + +24 + +# 25 Tables + +| | | | +|----|-------------------------------------------------------------|----| +| 26 | Table 4-1 :O-CU Performance Requirements ..... | 22 | +| 27 | Table 4-2: O-CU Interface Requirements ..... | 23 | +| 28 | Table 4-3: O-CU EMC Requirements ..... | 23 | +| 29 | Table 4-4: O-CU Mechanical Requirements ..... | 24 | +| 30 | Table 4-5: O-CU Thermal Requirements ..... | 24 | +| 31 | Table 4-6: O-CU Power Requirements ..... | 24 | +| 32 | Table 4-7: O-DU <sub>x</sub> Performance Requirements..... | 25 | +| 33 | Table 4-8: O-DU <sub>x</sub> Interface Requirements ..... | 26 | +| 34 | Table 4-9: O-DU <sub>x</sub> EMC Requirements ..... | 27 | +| 35 | Table 4-10: O-DU <sub>x</sub> Mechanical Requirements ..... | 27 | +| 36 | Table 4-11: O-DU <sub>x</sub> Thermal Requirements..... | 27 | +| 37 | Table 4-12: O-DU <sub>x</sub> Power Requirements..... | 28 | +| 38 | Table 4-13: O-DU <sub>7-2</sub> Specific Requirements ..... | 29 | + +| | | +|--------------------------------------------------------------------------------|----| +| Table 4-14: O-RU <sub>x</sub> Performance Requirements ..... | 29 | +| Table 4-15: O-RU <sub>x</sub> Interface Requirements ..... | 31 | +| Table 4-16: O-RU <sub>x</sub> Environmental and EMC Requirements..... | 31 | +| Table 4-17: O-RU <sub>x</sub> Mechanical, Thermal and Power Requirements ..... | 32 | + +## Figures + +| | | +|-----------------------------------------------------------------------------|----| +| Figure 2-1: Split Architecture..... | 12 | +| Figure 2-2: Integrated Architecture ..... | 12 | +| Figure 2-3: Option 6 to Option 6 Split Architecture ..... | 13 | +| Figure 2-4: Option 7-2 to Option 7-2 Split Architecture..... | 13 | +| Figure 2-5: Option 7-2 to Option 8 Split Architecture ..... | 13 | +| Figure 2-6: Option 8 to Option 8 Split Architecture ..... | 14 | +| Figure 2-7: Integrated gNB-DU Architecture ..... | 14 | +| Figure 3-1: O-CU White Box Hardware Block Diagram..... | 15 | +| Figure 3-2: O-DU <sub>7,2</sub> with Split Physical Layer Function..... | 16 | +| Figure 3-3: O-DU <sub>7,2</sub> Functional Block and Interface Diagram..... | 18 | +| Figure 3-4: O-RU <sub>7,2</sub> Architecture Diagram ..... | 20 | +| Figure 3-5: O-RU <sub>7,2</sub> Generic Functional Module Diagram ..... | 21 | + +# --- Chapter 1      Introductory Material + +## 1.1      Scope + +This Technical Specification has been produced by the O-RAN.org. + +The contents of the present document are subject to continuing work within O-RAN WG7 and may change following formal O-RAN approval. Should the O-RAN.org modify the contents of the present document, it will be re-released by O-RAN Alliance with an identifying change of release date and an increase in version number as follows: + +Release x.y.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. This variable is for internal WG7 use only. + +The present document specifies system requirements and high-level architecture for the Outdoor Micro Cell deployment scenario case as specified in the Deployment Scenarios and Base Station Classes document [1]. + +## 1.2      References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- [1] O-RAN-WG7.DSC.0-V01.00 Technical Specification, ‘Deployment Scenarios and Base Station Classes for White Box Hardware’. +- [2] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications". +- [3] 3GPP TR 38.104: "NR; Base Station (BS) radio transmission and reception". +- [4] O-RAN-WG4.CUS.0-v01.00 Technical Specification, ‘O-RAN Fronthaul Working Group Control, User and Synchronization Plane Specification’. +- [5] CPRI Specification V7.0 (2015-10-09) Interface Specification, ‘Common Public Radio Interface (CPRI). +- [6] Small Cell Forum, SCF222.10.02 5G FAPI: PHY API Specification, +[https://scf.io/en/documents/222\\_5G\\_FAPI\\_PHY\\_API\\_Specification.php](https://scf.io/en/documents/222_5G_FAPI_PHY_API_Specification.php) +- [7] 3GPP TS 38.113: “NR: Base Station (BS) Electromagnetic Compatibility (EMC) +- [8] O-RAN Architecture Description, O-RAN-WG1-O-RAN Architecture Description - v01.00.00 + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For the purposes of the present document, the terms and definitions given in 3GPP TR 21.905 [2] and the following apply. A term defined in the present document takes precedence over the definition of the same term, if any, in [2]. For the base station classes of Pico, Micro and Macro, the definitions are given in 3GPP TR 38.104 [3]. + +**Carrier Frequency:** Center frequency of the cell. + +**F1 interface:** The standard interface between an O-CU and an O-DU<sub>x</sub> specified in [8]. + +**Integrated architecture:** An architecture wherein the O-RU<sub>x</sub> and O-DU<sub>x</sub> are implemented on one platform. Each O-RU<sub>x</sub> and RF front end is associated with one O-DU<sub>x</sub> and is connected to O-CU via F1 interface. + +**Split architecture:** An architecture wherein O-RU<sub>x</sub> and O-DU<sub>x</sub> are physically separated from one another. A switch may aggregate multiple O-RU<sub>x</sub> (s) to one O-DU<sub>x</sub>. The O-DU<sub>x</sub>, switch and O-RU<sub>x</sub> (s) are connected by the fronthaul interface as defined in [4]. + +**Transmission Reception Point (TRxP):** Antenna array with one or more antenna elements available to the network located at a specific geographical location for a specific area. + +**Occupied Bandwidth (OBW):** It refers to the bandwidth occupied by the base station when operated, defined by the sum of the active bandwidths of the band allocation(s) operated. As defined by 3GPP TS 34.121 section 5.8, occupied bandwidth is the bandwidth containing 99% of the total integrated power of the transmitted spectrum, centered on the assigned channel frequency. The bandwidth between the 0.5% power frequency points is the occupied bandwidth. + +**Instantaneous Bandwidth (IBW):** It refers to the bandwidth in which all frequency components can be simultaneously analyzed. It is defined by the frequency boundaries of the operating band(s). + +**Frequency Range:** It refers to bandwidth defined by the frequency range within which the Base Station can be operated, defined by the band-pass filter of the BS; e.g., 3.4 – 3.8 GHz (400 MHz) + +**Frequency Band:** A designated frequency range for the operation of the base station and the UE radios. 5G NR frequency bands are divided into two different frequency ranges: Frequency Range 1 (FR1) that mainly includes sub-6GHz frequency bands, some of which are bands traditionally used by previous standards but has been extended to cover potential new spectrum offerings from 410MHz to 7125MHz; Frequency Range 2 (FR2) that includes frequency bands from 24.25 GHz to 52.6 GHz. Bands in this mmWave range have shorter range but higher available bandwidth than bands in the FR1. + +**Fronthaul Gateway (FHGW):** A fronthaul gateway is a physical entity that is located between a distributed unit and one or more radio units where it distributes, aggregates, and/or converts fronthaul protocols between the distributed unit and multiple radio units. + +Normative terms used in this specification are defined in following: + +Shall: indicates a requirement + +Should: indicated as recommendation + +May: indicates a permission + +### 1.3.2 Abbreviations + +For the purposes of the present document, the abbreviations given in [2] and the following apply. An abbreviation defined in the present document takes precedence over the definition of the same abbreviation, if any, as in [2]. + +| | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 7-2 | Fronthaul interface split option as defined by O-RAN WG4, also referred to as 7-2x | +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth-Generation Mobile Communications | +| 5GC | 5G Core | +| ACS | Adjacent Channel Selectivity | +| ADC | Analog to Digital Converter | +| ASIC | Application Specific Integrated Circuit | +| ATA | Advanced Technology Attachment | +| BPSK | Binary Phase Shift Keying | +| BS | Base Station | +| CDR | Clock/Data Recovery | +| CFR | Crest Factor Reduction | +| CU | Centralized Unit as defined by 3GPP | +| DAC | Digital to Analog Converter | +| DDC | Digital Down Conversion | +| DDR | Double Data Rate | +| DL | Downlink | +| DPD | Digital Pre-Distortion | +| DSP | Digital Signal Processor | +| DU | Distributed Unit as defined by 3GPP | +| DUC | Digital Up Conversion | +| EMC | ElectroMagnetic Compatibility | +| EVM | Error Vector Magnitude | +| FFT | Fast Fourier Transform | +| FH | Fronthaul | +| FHGW | Fronthaul Gateway | +| FHGW <sub>x</sub> | Fronthaul gateway with no FH protocol translation, supporting an O-DU <sub>x</sub> with split option x and an O-RU <sub>x</sub> with split option x, with currently available options 6→6, 7-2→7-2 and 8→8 | + +| | | | +|----|---------------------|---------------------------------------------------------------------------------------------------------| +| 1 | FHGW <sub>x→y</sub> | Fronthaul Gateway that can translate FH protocol from an O-DU <sub>x</sub> with split option x to an O- | +| 2 | | RU <sub>y</sub> with split option y, with currently available option 7-2 → 8. | +| 3 | FPGA | Field Programmable Gate Array | +| 4 | GbE | Gigabit Ethernet | +| 5 | GNSS | Global Navigation Satellite System | +| 6 | GPP | General Purpose Processor | +| 7 | IEEE | Institute of Electrical and Electronics Engineers | +| 8 | IMD | InterModulation Distortion | +| 9 | I/O | Input/Output | +| 10 | JTAG | Joint Test Action Group | +| 11 | L1 | Layer 1, also referred to as PHY or Physical Layer in OSI model | +| 12 | L2 | Layer 2, also referred to as Data Link layer in OSI model | +| 13 | L3 | Layer 3, also referred to as Network Layer in OSI model | +| 14 | LED | Light Emitting Diode | +| 15 | LTE | Long Term Evolution | +| 16 | MAC | Media Access Control | +| 17 | MCP | Multi-Chip Package | +| 18 | MIMO | Multiple Input Multiple Output | +| 19 | MTBF | Mean Time Between Failures | +| 20 | MU-MIMO | Multiple User MIMO | +| 21 | NG | Next Generation | +| 22 | NR | New Radio | +| 23 | OAM | Operations, Administrations and Maintenance | +| 24 | OBW | Occupied Bandwidth | +| 25 | O-CU | O-RAN Centralized Unit as defined by O-RAN | +| 26 | O-DU <sub>x</sub> | A specific O-RAN Distributed Unit having fronthaul split option x where x may be 6, 7-2 (as | +| 27 | | defined by WG4) or 8 | +| 28 | O-RU <sub>x</sub> | A specific O-RAN Radio Unit having fronthaul split option x, where x is 6, 7-2 (as defined | +| 29 | | by WG4) or 8, and which is used in a configuration where the fronthaul interface is the same | +| 30 | | at the O-DU <sub>x</sub> | +| 31 | PCIe | Peripheral Component Interface Express | +| 32 | PDCP | Packet Data Convergence Protocol | +| 33 | PHY | Physical Layer, also referred as L1 | +| 34 | PLL | Phase Locked Loop | +| 35 | POE | Power over Ethernet | +| 36 | QAM | Quadrature Amplitude Modulation | +| 37 | QPSK | Quadrature Phase Shift Keying | +| 38 | RAN | Radio Access Network | +| 39 | RF | Radio Frequency | + +| | | | +|----|------|-----------------------------------------| +| 1 | RLC | Radio Link Controller | +| 2 | RRC | Radio Resource Controller | +| 3 | RU | Radio Unit as defined by 3GPP | +| 4 | RX | Receiver | +| 5 | SDU | Service Data Unit | +| 6 | SFP | Small Form-factor Pluggable | +| 7 | SFP+ | Small Form-factor Pluggable Transceiver | +| 8 | SoC | System on Chip | +| 9 | SPI | Serial Peripheral Interface | +| 10 | TR | Technical Report | +| 11 | TRP | Total Radiated Power | +| 12 | TS | Technical Specification | +| 13 | TX | Transmitter | +| 14 | UL | Uplink | +| 15 | USB | Universal Serial Bus | +| 16 | WG | Working Group | + +# Chapter 2 Deployment Scenarios and White Box Base Station Architecture + +This chapter consists of two parts: the deployment scenario and the white box architecture. The deployment scenarios outline more specific functional requirements of the base station. All the reference designs shall meet these requirements in order to comply with O-RAN white box standard. In the white box hardware architecture section, it describes the overall gNB hardware architecture and function partition that meet the design requirements. The details on each of these topics are described in the following sections. + +## 2.1 Deployment Scenarios + +The specification here addresses a specific deployment scenario defined by the white box Deployment Scenarios and Base Station Classes document [1]. Its requirements are also defined in [1]. Some of the key requirements described in that document are highlighted below: + +- Cell type: Outdoor Micro Cell +- Mounting Options: Rooftop, side of building/wall, pole +- Inter site distance: 1.5 kilometers +- Possible Carrier Frequency Bands: n2, n4, n5, n13, n41, n48, n66, n77, n78, n79 +- [Instantaneous] Bandwidth: Up to 280 MHz +- Antennas Configuration: Up to 16T16R +- Coverage: Sectorized +- Conducted Power: up to 10W per port +- Number of Layers: Up to 16 layers +- Fronthaul Type: O-RAN FH (WG4) split option 7.2x. +- Architecture: Split architecture + +## 2.2 White Box Base Station Architecture + +In general, the base station hardware architecture can be classified by using different criteria. The physical partition method is adopted by O-RAN; hence, the base station architecture is divided into two categories namely split and integrated. In split architecture, the fronthaul interface determines the gNB functions location. Here we refer to the two partitions as O-DU<sub>x</sub> and O-RU<sub>x</sub>; where the “x” is split option number. In case the O-RAN WG4 defined fronthaul interface is used, these two partitions are called O-DU<sub>7-2</sub> and O-RU<sub>7-2</sub>. For a more complete description of the terminology used, refer to the Deployment Scenarios and Base Station Classes Document [1]. + +The split architecture is shown in Figure 2-1. A Fronthaul Gateway (FHGW) is an optional device between the O-DU<sub>x</sub> and O-RU<sub>x</sub> to aggregate multiple radio units together as shown in Figure 2-5. Within this specification, a Back End fronthaul interface is defined as the connection between the FHGW<sub>x</sub> and the O-DU<sub>x</sub>, while the Front + +End fronthaul interface is defined as the connection between the FHGW<sub>x</sub> and the O-RU<sub>x</sub>. With split architectures, one may choose to have O-CU and O-DU<sub>x</sub> as either co-located or shared configuration with respect to hardware. + +![Figure 2-1: Split Architecture diagram. A dashed box labeled 'O-CU & O-DU may be integrated into one Whitebox' contains two sub-boxes: 'O-CU' and 'O-DU_x' connected by a bidirectional dashed arrow. A solid arrow labeled 'Front Haul Interface' connects this dashed box to a separate dashed box labeled 'O-RU_x'.](e1a2465ddf14f51e655c7608e2f633a2_img.jpg) + +Figure 2-1: Split Architecture diagram. A dashed box labeled 'O-CU & O-DU may be integrated into one Whitebox' contains two sub-boxes: 'O-CU' and 'O-DU\_x' connected by a bidirectional dashed arrow. A solid arrow labeled 'Front Haul Interface' connects this dashed box to a separate dashed box labeled 'O-RU\_x'. + +**Figure 2-1: Split Architecture** + +For integrated base station architecture, the O-DU is integrated with the O-RU into one box. Figure 2-2 shows the integrated architecture. + +![Figure 2-2: Integrated Architecture diagram. A dashed box labeled 'O-CU' is connected via a solid arrow labeled 'F1 Interface' to a solid box labeled 'Switch/Router'. The 'Switch/Router' is then connected via multiple solid arrows labeled 'F1 Interface' to three separate dashed boxes, each labeled 'O-DU&O-RU'. Vertical ellipsis dots are shown between the middle and bottom 'O-DU&O-RU' boxes to indicate multiple units.](c01ea2b4af3438b84958476e4f1ade46_img.jpg) + +Figure 2-2: Integrated Architecture diagram. A dashed box labeled 'O-CU' is connected via a solid arrow labeled 'F1 Interface' to a solid box labeled 'Switch/Router'. The 'Switch/Router' is then connected via multiple solid arrows labeled 'F1 Interface' to three separate dashed boxes, each labeled 'O-DU&O-RU'. Vertical ellipsis dots are shown between the middle and bottom 'O-DU&O-RU' boxes to indicate multiple units. + +**Figure 2-2: Integrated Architecture** + +### 2.2.1 Split RAN Architecture + +For medium and large coverage deployment scenarios, the base station with split RAN architecture is more cost effective. This type of architecture is widely deployed in 4G networks. The main idea of this architecture is “shared cell”. By using the fronthaul gateway, many radio units can then share the same radio spectrum resource in one cell. This configuration is very useful in both low and high capacity scenarios. Therefore, when an O-DU<sub>x</sub> and FHGW<sub>x</sub> are capable of handling cell splits, multiple O-RU<sub>x</sub>(s) can be grouped together to share the radio resources. Accordingly, the choice of fronthaul split option changes the architecture of the base station. WG7 has recognized the following four split option architectures per service providers’ deployment needs which are shown in Figure 2-3 through Figure 2-6. + +#### 1) Option 6 to option 6 split architecture + +In split option 6, all L1 functions are within O-RU<sub>6</sub> while the O-DU<sub>6</sub> contains functions of MAC and above. Figure 2-3 shows the block diagram of base station having an option 6 split architecture. + +![Figure 2-3: Option 6 to Option 6 Split Architecture. The diagram shows a dashed box containing O-CU and O-DU6, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option6' connects this box to a 'Switch/Router or Fronthaul Gateway'. From the gateway, multiple arrows labeled 'FH Option6' connect to a stack of O-RU6 units.](bcec904190f3af44ebd18add77f587b2_img.jpg) + +Figure 2-3: Option 6 to Option 6 Split Architecture. The diagram shows a dashed box containing O-CU and O-DU6, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option6' connects this box to a 'Switch/Router or Fronthaul Gateway'. From the gateway, multiple arrows labeled 'FH Option6' connect to a stack of O-RU6 units. + +**Figure 2-3: Option 6 to Option 6 Split Architecture** + +#### 2) Option 7-2 to option 7-2 split architecture: + +In split option 7-2, low PHY functions reside in the O-RU<sub>7-2</sub>, while the high PHY functions reside in the O-DU<sub>7-2</sub>. O-RAN WG4 CUS-plane spec [4] outlines the details of this split option under different usage scenarios. + +![Figure 2-4: Option 7-2 to Option 7-2 Split Architecture. The diagram shows a dashed box containing O-CU and O-DU, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option7-2' connects this box to a 'Switch/Router or Fronthaul Gateway'. From the gateway, multiple arrows labeled 'FH Option7-2' connect to a stack of O-RU units.](06a264d2791f02ac2ae673b0333fdb3e_img.jpg) + +Figure 2-4: Option 7-2 to Option 7-2 Split Architecture. The diagram shows a dashed box containing O-CU and O-DU, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option7-2' connects this box to a 'Switch/Router or Fronthaul Gateway'. From the gateway, multiple arrows labeled 'FH Option7-2' connect to a stack of O-RU units. + +**Figure 2-4: Option 7-2 to Option 7-2 Split Architecture** + +#### 3) Option 7-2 to option 8 split: + +This configuration is selected when a deployment scenario requires a radio unit which only supports split option 8 architecture. Since this is currently not part of overall O-RAN architecture, CPRI based option 8 fronthaul and FHGW<sub>7-2→8</sub> will be included in the reference design specification. Figure 2-5 depicts the option 7-2 to option 8 based split architecture. There is no change for the definition of O-DU<sub>7-2</sub>. However, O-RU<sub>8</sub> supports option 8 fronthaul interface while the FHGW<sub>7-2→8</sub> translates the fronthaul protocol between option 7-2 and CPRI. + +![Figure 2-5: Option 7-2 to Option 8 Split Architecture. The diagram shows a dashed box containing O-CU and O-DU7-2, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option7-2' connects this box to a 'Fronthaul Gateway with Option Translator'. From the gateway, multiple arrows labeled 'FH Option8' connect to a stack of O-RU8 units.](ec5e7248434494681d254f4600de23ff_img.jpg) + +Figure 2-5: Option 7-2 to Option 8 Split Architecture. The diagram shows a dashed box containing O-CU and O-DU7-2, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option7-2' connects this box to a 'Fronthaul Gateway with Option Translator'. From the gateway, multiple arrows labeled 'FH Option8' connect to a stack of O-RU8 units. + +**Figure 2-5: Option 7-2 to Option 8 Split Architecture** + +#### 4) Option 8 to option 8 split architecture: + +Currently, Option 8 is a non-O-RAN defined split option where the CPRI fronthaul interface is needed in order to make the interoperability work with O-DU<sub>8</sub> and O-RU<sub>8</sub> from different vendors. The option 8 fronthaul interface definition and the requirements shall be part of the white box reference design, if adopted. In this case, the O-DU<sub>8</sub> consists of L1 and L2 processing functions. Figure 2-6 shows an option 8 based split architecture. Note that O-CU and O-DU<sub>8</sub> hardware may be integrated into one Whitebox this is also shown in Figure 2-6. + +![Figure 2-6: Option 8 to Option 8 Split Architecture. The diagram shows a dashed box on the left containing O-CU and O-DU8, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option8' connects this box to a 'Fronthaul Gateway' box. From the gateway, multiple arrows labeled 'FH Option8' connect to a vertical stack of O-RU8 boxes, with vertical ellipsis between the top and bottom O-RU8 boxes.](4ac919749c534a312f4bb025db592bd8_img.jpg) + +Figure 2-6: Option 8 to Option 8 Split Architecture. The diagram shows a dashed box on the left containing O-CU and O-DU8, with a note 'O-CU & O-DU may/may not be integrated into one Whitebox'. A solid arrow labeled 'FH Option8' connects this box to a 'Fronthaul Gateway' box. From the gateway, multiple arrows labeled 'FH Option8' connect to a vertical stack of O-RU8 boxes, with vertical ellipsis between the top and bottom O-RU8 boxes. + +Figure 2-6: Option 8 to Option 8 Split Architecture + +### 2.2.2 Integrated gNB-DU Architecture + +For integrated gNB-DU, the complete L1/L2 and radio functions are integrated into a single box which includes all logical functions of O-DU and O-RU. Figure 2-7 shows the block diagram of integrated gNB-DU. The gNB-DU connects with the O-CU through an F1 interface as defined by [8]. This specification does not support an integrated option [per requirements in Section 2.1]. + +![Figure 2-7: Integrated gNB-DU Architecture. The diagram shows a dashed box on the left containing O-CU. A solid double-headed arrow labeled 'F1' connects O-CU to a larger dashed box on the right. Inside this larger box, O-DU and O-RU are connected by a solid double-headed arrow. The entire larger box is labeled 'gNB-DU'.](6728d29c1dbbc492e6861104416d980a_img.jpg) + +Figure 2-7: Integrated gNB-DU Architecture. The diagram shows a dashed box on the left containing O-CU. A solid double-headed arrow labeled 'F1' connects O-CU to a larger dashed box on the right. Inside this larger box, O-DU and O-RU are connected by a solid double-headed arrow. The entire larger box is labeled 'gNB-DU'. + +Figure 2-7: Integrated gNB-DU Architecture + +# Chapter 3 White Box Hardware Architecture + +Based on the gNB physical implementation architectures discussed earlier, this chapter provides the architecture, major building blocks and all external/internal interfaces for each Whitebox. + +## 3.1 O-CU Hardware Architecture + +In a 3GPP system architecture, the gNB Central Unit (CU) communicates to the Distribution Unit (DU) via an F1 interface. This interface has been adopted by O-RAN Alliance as well. F1 is an IP based protocol interface, which offers more flexibility in the O-CU platform design. + +### 3.1.1 O-CU Architecture Diagram + +The O-CU can be implemented with any General-Purpose Processor (GPP) based platform having an optional hardware accelerator block. The O-CU functions can be implemented either on separated hardware platforms or on the same hardware platforms integrated with O-DU<sub>x</sub> functions. In either case, the O-CU hosts L2/L3 functions, whereas O-DU hosts L2/L1 functions which require different CPU, Storage, Acceleration and Networking capabilities. Figure 3-1 shows the hardware blocks and interfaces within the O-CU white box. + +![Figure 3-1: O-CU White Box Hardware Block Diagram. The diagram shows a dashed box labeled 'O-CU' containing three main components: 'Ethernet Interface', 'Digital Processing Unit', and 'Hardware Accelerator'. The 'Ethernet Interface' on the left connects to 'Backhaul (Ethernet or Wireless)'. The 'Digital Processing Unit' is connected to both the 'Ethernet Interface' and the 'Hardware Accelerator'. The 'Hardware Accelerator' is connected to the 'Digital Processing Unit'. An 'Ethernet Interface' on the right connects to the 'Digital Processing Unit' and the 'F1 Interface (Ethernet)'.](012b7eed69b3f26856a38baaf7286c44_img.jpg) + +``` + +graph LR + subgraph O-CU + EI1[Ethernet Interface] <--> DPU[Digital Processing Unit] + DPU <--> HA[Hardware Accelerator] + EI2[Ethernet Interface] <--> DPU + EI2 <--> F1[F1 Interface Ethernet] + end + Backhaul[Backhaul Ethernet or Wireless] <--> EI1 + +``` + +Figure 3-1: O-CU White Box Hardware Block Diagram. The diagram shows a dashed box labeled 'O-CU' containing three main components: 'Ethernet Interface', 'Digital Processing Unit', and 'Hardware Accelerator'. The 'Ethernet Interface' on the left connects to 'Backhaul (Ethernet or Wireless)'. The 'Digital Processing Unit' is connected to both the 'Ethernet Interface' and the 'Hardware Accelerator'. The 'Hardware Accelerator' is connected to the 'Digital Processing Unit'. An 'Ethernet Interface' on the right connects to the 'Digital Processing Unit' and the 'F1 Interface (Ethernet)'. + +**Figure 3-1: O-CU White Box Hardware Block Diagram** + +### 3.1.2 O-CU Functional Module Description + +The O-CU functional architecture comprises Digital Signal Processing, optional HW Acceleration, and Connectivity (GbE) units as well as memory and storage units as shown in Figure 3-1. + +### 3.1.3 O-CU Interfaces + +The O-CU interfaces through backhaul with the vEPC or 5GC core network and via F1 interface with the O-DU<sub>7-2</sub>. The backhaul and the F1 interfaces are typically implemented with GbE transport/connections. + +## 3.2 O-DU<sub>7-2</sub> Hardware Architecture + +For a split RAN architecture, the functional blocks of the RAN physical layer are divided into two parts – high PHY and low PHY. The O-RAN lower layer split is defined in O-RAN WG4 fronthaul interface specification [4]. It also provides the details of the interface protocol as well as function partitions. + +### 3.2.1 O-DU<sub>7-2</sub> Architecture Diagram + +Depending on the 3GPP standards and category of the radio unit, the split function blocks within O-DU<sub>7-2</sub> and O-RU<sub>7-2</sub> may vary accordingly. The O-RAN fronthaul C/U/S-plane specification [4] provides comprehensive information on this topic. The hardware functional partition architecture is shown in Figure 3-2. The High-PHY functions in O-DU are run on Digital Processing Unit, Hardware Accelerator, or both. + +![Figure 3-2: O-DU7-2 with Split Physical Layer Function. The diagram shows the hardware architecture of O-DU7-2 and its connection to O-RU7-2. O-DU7-2 is enclosed in a dashed box and contains a Hardware Accelerator, a Digital Processing Unit (DPU), and two Ethernet Interfaces. The DPU is connected to the Hardware Accelerator and one Ethernet Interface. The other Ethernet Interface is connected to the DPU and a Timing and Synchronization (IEEE 1588) block. The Timing and Synchronization block provides PPS (IN or OUT) to the DPU. The DPU is also connected to the second Ethernet Interface. The second Ethernet Interface is connected to the O-RAN FH Interface, which is connected to the Low PHY block in O-RU7-2. The F1 Interface is connected to the first Ethernet Interface.](0d3cbc0655057943f64042af4619ca8c_img.jpg) + +``` + +graph LR + subgraph ODU72 [O-DU7-2] + HA[Hardware Accelerator] + DPU[Digital Processing Unit] + TS[Timing and Synchronization +(IEEE 1588)] + EI1[Ethernet Interface] + EI2[Ethernet Interface] + HA <--> DPU + DPU <--> TS + TS -- "PPS (IN or OUT)" --> DPU + DPU <--> EI2 + end + EI1 <--> F1[F1 Interface] + EI2 <--> OFH[O-RAN FH Interface] + OFH <--> LPHY[Low PHY] + subgraph ORU72 [O-RU7-2] + LPHY + end + +``` + +Figure 3-2: O-DU7-2 with Split Physical Layer Function. The diagram shows the hardware architecture of O-DU7-2 and its connection to O-RU7-2. O-DU7-2 is enclosed in a dashed box and contains a Hardware Accelerator, a Digital Processing Unit (DPU), and two Ethernet Interfaces. The DPU is connected to the Hardware Accelerator and one Ethernet Interface. The other Ethernet Interface is connected to the DPU and a Timing and Synchronization (IEEE 1588) block. The Timing and Synchronization block provides PPS (IN or OUT) to the DPU. The DPU is also connected to the second Ethernet Interface. The second Ethernet Interface is connected to the O-RAN FH Interface, which is connected to the Low PHY block in O-RU7-2. The F1 Interface is connected to the first Ethernet Interface. + +**Figure 3-2: O-DU<sub>7-2</sub> with Split Physical Layer Function** + +### 3.2.2 O-DU<sub>7-2</sub> Functional Module Description + +The choice of O-DU<sub>7-2</sub> hardware components depends on the product design requirements and is outside the scope of this specification. Figure 3-3 shows the main components of O-DU<sub>7-2</sub>. Their descriptions and requirements are as follows: + +#### Digital Processing Unit + +1 The processing unit can be any GPP, FPGA or digital signal processor (DSP), with I/O chipset. It may also be in +2 the form of System-On-Chip (SOC), or Multi-Chip Package (MCP). + +#### 3 **Memory** + +4 DDR memory devices are used to store the runtime data and software for the processing unit. + +#### 5 **Flash Memory** + +6 On board non-volatile storage device is used to store the firmware and non-volatile data, such as log data. + +#### 7 **Board Management Controller** + +8 The controller is used to manage/control the power and monitors the operational status of the board. + +#### 9 **Storage Device** + +10 The storage device such as hard drive is used to store OS, driver and applications software. + +#### 11 **Ethernet Controller** + +12 The Ethernet ports transport the fronthaul or backhaul traffic according to the gNB hardware node requirements. +13 The Ethernet device shall support IEEE1588 based timing synchronization. + +#### 14 **Hardware Accelerator** + +15 The hardware accelerator is an optional device. For performance improvement, the hardware accelerator can be +16 used to process computationally-intensive functions (e.g., Forward Error Correction (FEC)) and to offload the +17 processor. + +![Figure 3-3: O-DU7-2 Functional Block and Interface Diagram. The diagram shows a central 'Digital Processing Unit' block. To its left, an 'Accelerator' is connected via 'PCIe'. Below that, 'USB Ports' are connected via 'USB', 'Video Port' via 'VGA', 'PCIe Slots' via 'PCIe', 'Serial Ports' via 'RS232', and 'Timing' via 'Timing Signal'. To the right of the 'Digital Processing Unit', 'DDR RAM' is connected via 'Memory Channel', 'Flash Memory' via 'SPI', 'SMBus Port' via 'SMBus', 'Storage Drives' via 'SATA', and 'Ethernet Ports' via 'Ethernet'.](25842ee03b6480e1c3de9aad2bca05f7_img.jpg) + +Figure 3-3: O-DU7-2 Functional Block and Interface Diagram. The diagram shows a central 'Digital Processing Unit' block. To its left, an 'Accelerator' is connected via 'PCIe'. Below that, 'USB Ports' are connected via 'USB', 'Video Port' via 'VGA', 'PCIe Slots' via 'PCIe', 'Serial Ports' via 'RS232', and 'Timing' via 'Timing Signal'. To the right of the 'Digital Processing Unit', 'DDR RAM' is connected via 'Memory Channel', 'Flash Memory' via 'SPI', 'SMBus Port' via 'SMBus', 'Storage Drives' via 'SATA', and 'Ethernet Ports' via 'Ethernet'. + +**Figure 3-3: O-DU<sub>7-2</sub> Functional Block and Interface Diagram.** + +### 3.2.3 O-DU<sub>7-2</sub> Interfaces + +The O-DU<sub>7-2</sub> supported interfaces described below are also shown in Figure 3-3. + +#### Memory Channel Interface + +Support DDR4 and later memory interface. + +#### PCIe Interface + +Support for PCIe Gen3 x16 and later interface versions; the bandwidth depends on the use cases, and it can be used to connect an accelerator device or network card. + +#### Ethernet Interfaces + +Supports any one or combination of GbE/10GbE/25GbE/40GbE links. + +#### Serial ATA Interface + +SATA3 shall be supported in case of software storage, such as hard drive. + +#### SPI Interface + +The SPI interface connects the processor with flash type of device for firmware. + +#### Video Interface + +Video interface is optional + +#### USB Interface + +1 Used to connect with local device for debug or on-board firmware update. + +#### 2 **Miscellaneous Interface** + +3 Other interfaces that may be needed such as serial port, JTAG, etc. + +###### 4 **3.3 O-DU<sub>6</sub> Hardware Architecture** + +5 This section intentionally left blank. + +###### 6 **3.4 O-DU<sub>8</sub> Hardware Architecture** + +7 This section intentionally left blank. + +###### 8 **3.5 FHGW<sub>7-2</sub> - Option 7-2 to Option 7-2 Hardware Architecture** + +9 This section intentionally left blank. + +###### 10 **3.6 FHGW<sub>6</sub> - Option 6 to Option 6 Hardware Architecture** + +11 This section intentionally left blank. + +###### 12 **3.7 FHGW<sub>7-2->8</sub> - Option 7-2 to Option 8 Hardware Architecture** + +13 This section intentionally left blank. + +###### 14 **3.8 FHGW<sub>8</sub> - Option 8 to Option 8 Hardware Architecture** + +15 This section intentionally left blank. + +###### 16 **3.9 O-RU<sub>7-2</sub> Hardware Architecture** + +17 O-RU<sub>7-2</sub> consists of four modules, namely optical interface, digital processing unit, RF processing unit and +18 antenna unit, as well as a timing unit as shown in Figure 3-4. The Ethernet interface complies with O-RAN +19 WG4 open fronthaul interface. The O-RU<sub>7-2</sub> can directly connect with an O-DU<sub>7-2</sub> or connect through a FHGW<sub>7-2</sub>. +20 2. While the O-RU<sub>7-2</sub> hardware supports NR by default, LTE support is not precluded. + +### 3.9.1 O-RU<sub>7-2</sub> Architecture Diagram + +The O-RU<sub>7-2</sub> hardware architecture consists of the digital processing unit which handles all digital signal and interface processing and an RF processing unit handling all analog. There is a data conversion block for each transceiver path after the digital processing block which converts between digital signals and analog signals. A frequency conversion or mixer unit may be used to convert the IF or baseband frequencies to RF frequencies and vice versa. In some cases, a direct RF sampling transceiver is used, where no external mixer is required. The PA/LNA amplifies the RF signal, and the antenna module is used to transmit and receive signal over the air. There is at least one Ethernet port available which is used as the O-RAN fronthaul interface. + +![Figure 3-4: O-RU7-2 Architecture Diagram. The diagram shows the internal components of an O-RU7-2 unit. A dashed box labeled 'O-RU7-2' encloses the main processing blocks. On the left, an 'O-RAN FH' interface connects to an 'eCPRI' block. The 'eCPRI' block is connected to a 'Digital Processing Unit', which is in turn connected to an 'RF Processing Unit'. Below these, a 'Timing Unit' receives 'Local timing from CDR' and 'Local timing from GNSS or equivalent' (via an optional 'GNSS (optional)' antenna). The 'Timing Unit' provides timing to the 'eCPRI', 'Digital Processing Unit', and 'RF Processing Unit'. At the bottom, a 'Power Unit' provides power to the 'Timing Unit', 'Digital Processing Unit', and 'RF Processing Unit'.](c421e42fccfddef62ef4953e8f5e5cff_img.jpg) + +``` + +graph LR + subgraph O-RU7-2 + eCPRI[eCPRI] <--> DPU[Digital Processing Unit] + DPU <--> RPU[RF Processing Unit] + TU[Timing Unit] + PU[Power Unit] + GNSS[GNSS optional] + + GNSS -- "Local timing from GNSS or equivalent" --> TU + CDR[Local timing from CDR] --> TU + TU --> eCPRI + TU --> DPU + TU --> RPU + PU --> TU + PU --> DPU + PU --> RPU + end + O-RAN-FH[O-RAN FH] <--> eCPRI + eCPRI <--> ToFrom[To/From O-DU7-2] + +``` + +Figure 3-4: O-RU7-2 Architecture Diagram. The diagram shows the internal components of an O-RU7-2 unit. A dashed box labeled 'O-RU7-2' encloses the main processing blocks. On the left, an 'O-RAN FH' interface connects to an 'eCPRI' block. The 'eCPRI' block is connected to a 'Digital Processing Unit', which is in turn connected to an 'RF Processing Unit'. Below these, a 'Timing Unit' receives 'Local timing from CDR' and 'Local timing from GNSS or equivalent' (via an optional 'GNSS (optional)' antenna). The 'Timing Unit' provides timing to the 'eCPRI', 'Digital Processing Unit', and 'RF Processing Unit'. At the bottom, a 'Power Unit' provides power to the 'Timing Unit', 'Digital Processing Unit', and 'RF Processing Unit'. + +Figure 3-4: O-RU<sub>7-2</sub> Architecture Diagram + +### 3.9.2 O-RU<sub>7-2</sub> Functional Module Description + +In Figure 3-5, we illustrate O-RU<sub>7-2</sub> functional blocks that support O-RAN FH with split option 7-2x. There is at least one interface port which supports all fronthaul interface and PoE functionalities. The digital processing unit block of O-RU<sub>7-2</sub> is responsible for low-PHY functions such as FFT/IFFT, CP addition/removal, and PRACH + +filtering. Digital Down Converter (DDC), Digital Up Converter (DUC), Crest Factor Reduction (CFR) and Digital Pre-Distortion (DPD) functions are also performed in digital processing unit. For bandwidth reduction, O-RU<sub>7-2</sub> architecture also supports the optional compression and decompression functions of FH interface. The ADC and DAC are mixed signal devices responsible for conversion of data between the digital and analog domains. As such, this block can be included as part of either the digital processing unit or the radio processing unit. The RF Processing Unit consists of an optional frequency converter (mixer), Power Amplifier (PA)/ Low Noise Amplifier (LNA) and TX/RX filters. An antenna module follows that comprises physical antennae, RF feed distribution/aggregation network, and calibration network. The timing unit includes any clock and frequency synthesis required as well as other timing and synchronization circuits. In any given implementation, the physical boundaries between blocks may be slightly different, but the logical interfaces between will generally follow those shown in Figure 3-5. + +![Figure 3-5: O-RU7-2 Generic Functional Module Diagram. The diagram shows a block diagram of the O-RU7-2 architecture. It is divided into two main sections: 'Digital Signal Processing Module' and 'RF Processing and Antenna Modules'. The 'Digital Signal Processing Module' includes blocks for 'Optical Interface', 'eCPRI', 'O-RAN FH/ IEEE 1588v2', '(De-) Compression Low-PHY', 'DDC/ DUC', 'CFR/ DPD', and 'ADC/ DAC'. The 'RF Processing and Antenna Modules' section includes 'Mixer', 'PA/LNA/ and TX/RX Filters', and 'Antenna Module'. Arrows indicate data flow between these blocks. A 'Timing/LO' input is shown at the bottom, connected to the 'Mixer' and 'ADC/ DAC' blocks. The entire system is labeled 'O-RU7-2x' at the bottom left, and 'To/From O-DU7-2x' is shown at the top left.](235455b69e6103354739088b5053458c_img.jpg) + +Figure 3-5: O-RU7-2 Generic Functional Module Diagram. The diagram shows a block diagram of the O-RU7-2 architecture. It is divided into two main sections: 'Digital Signal Processing Module' and 'RF Processing and Antenna Modules'. The 'Digital Signal Processing Module' includes blocks for 'Optical Interface', 'eCPRI', 'O-RAN FH/ IEEE 1588v2', '(De-) Compression Low-PHY', 'DDC/ DUC', 'CFR/ DPD', and 'ADC/ DAC'. The 'RF Processing and Antenna Modules' section includes 'Mixer', 'PA/LNA/ and TX/RX Filters', and 'Antenna Module'. Arrows indicate data flow between these blocks. A 'Timing/LO' input is shown at the bottom, connected to the 'Mixer' and 'ADC/ DAC' blocks. The entire system is labeled 'O-RU7-2x' at the bottom left, and 'To/From O-DU7-2x' is shown at the top left. + +Figure 3-5: O-RU<sub>7-2</sub> Generic Functional Module Diagram + +## 3.10 O-RU<sub>6</sub> Hardware Architecture + +This section intentionally left blank. + +## 3.11 O-RU<sub>8</sub> Hardware Architecture + +This section intentionally left blank. + +## 3.12 Integrated gNB-DU Hardware Architecture + +This section intentionally left blank. + +# Chapter 4 White Box Hardware Requirements + +This chapter provides the requirements for various white boxes used within the Outdoor Microcell base station. These white boxes are O-CU, O-DU<sub>x</sub>, O-RU<sub>x</sub> and FHGW<sub>x</sub>. The O-CU and O-DU<sub>x</sub> can be implemented in an integrated fashion into one white box hardware or they can be separated. The reference design based on specification shall meet all these requirements based on their priority as specified by operators. + +## 4.1 O-CU Requirements + +O-CU requirements are described in the following sections, which include the performance, interface, environmental, EMC, mechanical, thermal and power requirements. + +### 4.1.1 O-CU Performance + +The performance requirements of the O-CU are listed in Table 4-1. + +**Table 4-1 :O-CU Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------------------------|--------------------------------------------------------------------------------------------------------|------------------------------------------------------------|----------| +| Synchronization | Support 1588v2 Synchronization | Timing synchronization method | High | +| | Support GNSS Synchronization | | High | +| | Support BeiDou Synchronization | | Low | +| | Support Galileo Synchronization | | Low | +| | Support GLONASS Synchronization | | Low | +| | Support switching between 1588v2 and GNSS | | High | +| | Support SyncE | | Low | +| Number of O-DU <sub>x</sub> supported | For O-CU/O-DU <sub>x</sub> integrated architecture: N/A | Number of O-DU <sub>x</sub> (s) connected to a single O-CU | None | +| | For O-CU/O-DU <sub>x</sub> non-integrated architecture: Determined by operator deployment requirements | | High | +| Supported Cell Number | For O-CU/O-DU <sub>x</sub> integrated architecture: N/A | Cells supported by an O-CU | None | +| | For O-CU/O-DU <sub>x</sub> non-integrated architecture: Determined by operator deployment requirements | | High | + +| | | | | +|--------------------------------------|--------------------------------------------------------------------------------------------------------|---------------------------------------------------------|------| +| Supported RRC link number | For O-CU/O-DU <sub>x</sub> integrated architecture: N/A | RLC links supported by O-CU | None | +| | For O-CU/O-DU <sub>x</sub> non-integrated architecture: Determined by operator deployment requirements | | High | +| Throughput between O-DU <sub>x</sub> | For O-CU/O-DU <sub>x</sub> integrated architecture: N/A | Throughput between O-CU and O-DU <sub>x</sub> link | None | +| | For O-CU/O-DU <sub>x</sub> non-integrated architecture: Determined by operator deployment requirements | | High | +| Peak Data Rate | TBD | Highest theoretical data rate in error free conditions. | None | +| Latency | Control Plane < 10ms (def: Msg1 to Msg5)<br>User Plane DL < 4ms UL < 4ms (def: PDCP SDU - > PDCP SDU) | O-CU latency | High | + +### 4.1.2 O-CU Interfaces + +The interface requirements of the O-CU are listed in Table 4-2: O-CU Interface Requirements. + +**Table 4-2: O-CU Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------|-------------------------------------------------------------------------------------------------------------------|---------------------------------------------------|----------| +| Transport Interface | 10 GbE F1 Interface to connect with O-DU <sub>x</sub> or<br>25 GbE F1 Interface to connect with O-DU <sub>x</sub> | O-CU transport links to O-DU <sub>x</sub> and 5GC | High | +| | 10 GbE NG interface to connect with 5G core <sup>(b)</sup> or<br>25 GbE NG interface to connect with 5G core | | High | +| | | | | + +### 4.1.3 O-CU Environmental and EMC + +The EMC requirements of the O-CU are listed in Table 4-3. + +**Table 4-3: O-CU EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------|------------------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| EMC | Shall comply with the requirements of 3GPP TS 38.113 (2017-12 Rel-15) [7] for equipment used in telecommunication room | Electromagnetic Compatibility requirement | High | + +Note: For O-CU and O-DU<sub>x</sub> integrated solution, this requirement for O-CU portion is captured in the following O-DU<sub>x</sub> section. + +### 4.1.4 O-CU Mechanical, Thermal and Power + +The mechanical, thermal and power requirements of the O-CU are listed in the following tables. + +**Table 4-4: O-CU Mechanical Requirements** + +| Parameter | Requirement | Description | Priority | +|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------|----------| +| Dimensions | Built in any 19" standard rack, or stand alone, with overall height of no more than 5U <sup>(a)</sup> and depth (including the connector) less than 750mm. | Measurement in three dimensions | Low | +| Status Indicator LED | Shall include as a minimum the following status indicators:<br>---1 indicating on/off status of the power supply<br>---1 indicating on/off status of the transmission link | Indicator light | High | + +Note: + +(a) Note that this dimension is application dependent and its value may change accordingly. + +**Table 4-5: O-CU Thermal Requirements** + +| Parameter | Requirement | Description | Priority | +|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------|----------| +| Temperature and Humidity | Operate steadily and reliably over a long period of time under the following environmental conditions for data center:<br><br>Operating Temperature: - 0 °C ~ + 50 °C<br><br>Relative humidity: 15% ~ 85% | Environmental requirements for reliability | High | +| | The solution should support extended temperature range (-40°C to +65 °C) and humidity (5%-95%) if implemented outdoors. | Environmental requirements for reliability | Low | + +Note: For O-CU and O-DU<sub>x</sub> integrated solution, this requirement for O-CU portion is captured in the following O-DU<sub>x</sub> section. + +**Table 4-6: O-CU Power Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------|-------------|-------------|----------| +|-----------|-------------|-------------|----------| + +| | | | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------|------| +| Power Supply | DC -48 VDC (-40v ~ -57v) (can be connected to AC/DC converter) or AC 220V power supply, voltage range of 140V~ 300v, frequency range of 45Hz ~ 65Hz. | Power supply for O-CU | High | +| Power Dissipation | < TBD W full load operation | O-CU Power Requirement | High | + +Note: For O-CU and O-DU<sub>x</sub> integrated solution, this requirement for O-CU portion is captured in the following O-DU<sub>x</sub> section. + +## 4.2 O-DU<sub>x</sub> Common Requirements + +The O-DU<sub>x</sub> here takes the function of high PHY or whole PHY, OAM function and layer 2. Usually the hardware is placed in the machine room, which can be collocated in the coverage building or in the central machine room far away from the coverage building. + +### 4.2.1 O-DU<sub>x</sub> Performance + +The performance requirements of the O-DU<sub>x</sub> are listed in Table 4-7. + +**Table 4-7: O-DU<sub>x</sub> Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------------------------------------|---------------------------------------------------------------------------------------------------------------|-----------------------------------------------|----------| +| Channel Bandwidth | ≤200 MHz OBW | RF Bandwidth | High | +| Antenna Configuration<br>(Number of Transceivers) | 4T4R | Tx/Rx antenna number | High | +| | up to 16T16R | | Low | +| Transmission distance | Measured in delay. TBD | Distance between DU and FHGW <sub>x</sub> /RU | High | +| Connect Topology | NA | Fronthaul Gateway connection topology | None | +| Synchronization | Support 1588v2 Synchronization | Timing synchronization method | High | +| | Support GNSS Synchronization;<br>Sync. between BS ≤ 150 ns; Carrier freq. error within one subframe <±0.1 PPM | | High | + +| | | | | +|---------------|-----------------------------------------------------------------------------------------------------|----------------------------|--------| +| | Support BeiDou Synchronization | | Low | +| | Support Galileo Synchronization | | Low | +| | Support GLONASS Synchronization | | Low | +| | Support switching between 1588v2 and GNSS | | High | +| | Support SyncE | | Low | +| Capacity/MIMO | 4T4R: 4 layers and 200 MHz OBW | MIMO related capability | High | +| | up to 16T16R and TBD | | Low | +| Peak Rate | TBD | Peak data rate | High | +| Modulation | DL: QPSK, 16QAM, 64QAM, 256QAM<br>UL: $\pi/2$ -bpsk, QPSK, 16QAM, 64QAM | Modulation schemes | High | +| | UL: 256QAM | | Medium | +| Latency | Control Plane < 10ms (def: Msg1 to Msg5)<br>User Plane DL < 4ms UL < 4ms (def: PDCP SDU-> PDCP SDU) | Control/user plane Latency | High | + +### 4.2.2 O-DU<sub>x</sub> Interfaces + +The interface requirements of the O-DU<sub>x</sub> are listed in Table 4-8. + +**Table 4-8: O-DU<sub>x</sub> Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------|----------------------------------------------------------------------|-----------------------------------|----------| +| Transport Interface | Fronthaul Gateway: N/A | O-DU <sub>x</sub> transport links | None | +| | At least one 10 GbE F1 interface to connect with O-CU <sup>(b)</sup> | | High | + +Notes: + +(a) For O-CU and O-DU<sub>x</sub> that are co-located + +(b) For O-CU and O-DU<sub>x</sub> that are separated physically + +### 4.2.3 O-DU<sub>x</sub> Environmental and EMC + +The EMC requirements of the O-DU<sub>x</sub> are listed in Table 4-9. + +**Table 4-9: O-DU<sub>x</sub> EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------|-----------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| EMC | Complying with the requirements of 3GPP TS 38.113 (2017-12R15) [7] for equipment used in telecommunication room | Electromagnetic Compatibility requirement | High | + +### 4.2.4 O-DU<sub>x</sub> Mechanical, Thermal and Power + +The mechanical requirements of the O-DU<sub>x</sub> are listed in Table 4-10. + +**Table 4-10: O-DU<sub>x</sub> Mechanical Requirements** + +| Parameter | Requirement | Description | Priority | +|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------|----------| +| Dimension | Built in any 19" standard rack, or stand alone, and the height does not exceed 5U <sup>(a)</sup> , the depth (including the connector) must be less than 750mm. | Measurement in three dimensions | Low | +| Status Indicator LED | Shall include as a minimum the following status indicators:<br>---1 indicating the on/off status of optical fiber interface<br>---1 indicating off status of the power supply<br>---1 indicating on/off status of the transmission link | Indicator lights | High | + +Note: + +(a) Note that this dimension is application dependent and its value may change accordingly. + +The thermal requirements of the O-DU<sub>x</sub> are listed in Table 4-11. + +**Table 4-11: O-DU<sub>x</sub> Thermal Requirements** + +| Parameter | Requirement | Description | Priority | +|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------|----------| +| Temperature and Humidity | The O-DU <sub>x</sub> shall operate steadily and reliably over a long period of time under the following environmental conditions for data center:<br><br>Operating Temperature: - 0 °C ~ + 50 °C<br><br>Relative humidity: 15% ~ 85% | Environmental requirements for reliability | High | +| | The solution should support extended temperature range (-40°C to +65 °C) and humidity (5%-95%) if implemented outdoors. | Environmental requirements for reliability | Low | + +**Table 4-12: O-DU<sub>x</sub> Power Requirements** + +| Parameter | Requirement | Description | Priority | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------|----------| +| Power Supply | DC -48 VDC (-40v ~ -57v) (can be connected to AC/DC converter) or AC 220V power supply, voltage range of 140V~ 300v, frequency range of 45Hz ~ 65Hz. | Power supply for O-DU <sub>x</sub> | High | +| Power Dissipation | < TBD W, with 4 cells full load operation | O-DU <sub>x</sub> Power Requirement | High | +| | < TBD W, with 8 cells full load operation | | Medium | + +## 4.3 O-DU<sub>x</sub> Split Option Specific Requirements + +In addition to the common O-DU<sub>x</sub> requirements, there may be some specific requirements that apply to O-DU<sub>x</sub> due to the split option. These requirements are listed in the following sections. + +### 4.3.1 O-DU<sub>7-2</sub> Specific Requirements + +The specific requirements of O-DU<sub>7-2</sub> are listed in Table 4-13. + +**Table 4-13: O-DU<sub>7-2</sub> Specific Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------|-----------------------------------------------------------------|-----------------------------------------------|----------| +| Transport Interface | At least 4 Ethernet interfaces connected with Fronthaul Gateway | O-DU <sub>7-2</sub> fronthaul transport links | High | + +### 4.3.2 O-DU<sub>6</sub> Specific Requirements + +This section intentionally left blank. + +### 4.3.3 O-DU<sub>8</sub> Specific Requirements + +This section intentionally left blank. + +## 4.4 O-RU<sub>x</sub> Common Requirements + +The O-RU<sub>x</sub> common requirements apply to all the radio units regardless of the split option. In the indoor environment, O-RU<sub>x</sub> hardware is placed on the cell or wall of the coverage building; it converts the base band signal into RF signal or vice versa to supply the coverage. + +### 4.4.1 O-RU<sub>x</sub> Performance + +The O-RU<sub>x</sub> performance requirements cover all the aspects of radio unit including frequency bands, antenna configurations, power efficiency, etc. Table 4-14 lists the performance parameters related to O-RU<sub>x</sub>. + +**Table 4-14: O-RU<sub>x</sub> Performance Requirements** + +| Parameter | Requirement | Description | Priority | +|---------------------------------------------------|--------------------------------------|-----------------------|----------| +| Operating band | n77 | Radio frequency band | High | +| | n2, n4, n13, n41, n48, n66, n78, n79 | | Low | +| [Occupied] Bandwidth | ≤200 MHz | Frequency bandwidth | High | +| Antenna Configuration<br>(Number of Transceivers) | 4T4R | Tx/Rx Antenna numbers | High | +| | up to 16T16R | | Low | + +| | | | | +|-----------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------|--------| +| Output Power Accuracy | Under normal condition: $\pm 2$ dB | Power accuracy | High | +| Tx off Power Level | less than -85dBm/MHz; See section 6.4.1 in 3GPP TS 38.104 [3]. | Tx power level during an off period | High | +| EVM at maximum output power | 64QAM: EVM smaller than 8%<br>256QAM: EVM smaller than 3.5% | Max output power | High | +| Operating band unwanted emissions | The Operating band unwanted emissions shall satisfy the Category B limit defined by the section 6.6.4.2.4 in 3GPP TS 38.104 [3]. | RF operation band unwanted emissions requirement | High | +| Transmitter spurious emissions | The Operating band unwanted emissions shall satisfy the Category B limit defined by the section 6.6.4.2.4 in [3]. | Deliberately generated RF signal by transmitter | High | +| Receiver Sensitivity | The throughput shall be $\geq 95\%$ of the maximum throughput of the reference measurement channel of G-FR1-A1-5; the reference sensitivity levels shall be better than -95.6dBm. | The weakest signal the receiver can identify and process | High | +| Blocking | In Channel selection, ACS, In-band blocking, out-band blocking, IMD and other receiver specification shall follow the 3GPP guidelines in [3] <sup>[5]</sup> , the reference sensitivity is allowed to degrade at most 6dB under all kinds of interference signal and corresponding level. | Channel selection related requirement | High | +| Other specifications | Except for all the RF specifications listed above, other RF specifications shall follow the requirement in [3]. | Additional standard to comply | High | +| Downlink modulation Mode | QPSK, 16-QAM, 64-QAM, 256-QAM | DL Modulation schemes | High | +| Uplink modulation mode | $\pi/2$ -BPSK, QPSK, 16-QAM, 64-QAM | UL Modulation schemes | High | +| | 256QAM | | medium | +| Conducted Power | 4T4R: up to 10W per port | RF power | High | +| | 16T16R: TBD | | Low | + +### 4.4.2 O-RU<sub>x</sub> Interfaces + +The interface related requirements of the O-RU<sub>x</sub> are listed in Table 4-15. + +**Table 4-15: O-RU<sub>x</sub> Interface Requirements** + +| Parameter | Requirement | Description | Priority | +|------------------|-------------------------------------------------------------------------------------------------------|---------------------------|----------| +| Interface Number | The O-RU <sub>x</sub> shall have at least one fronthaul interface based on the split option supported | Number of fronthaul links | High | + +### 4.4.3 O-RU<sub>x</sub> Environmental and EMC + +The environmental and EMC requirements of the O-RU<sub>x</sub> are listed in Table 4-16. + +**Table 4-16: O-RU<sub>x</sub> Environmental and EMC Requirements** + +| Parameter | Requirement | Description | Priority | +|-----------------|----------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------|----------| +| Mounting method | Rooftop, side of building/wall or pole | Mounting requirement | High | +| Grounding | The O-RU <sub>x</sub> shall support Joint Grounding Method and shall work normally when the grounding resistor is less than 10Ω. | Grounding requirement | High | +| EMC | The O-RU <sub>x</sub> shall comply with the requirements of 3GPP TS 38.113 [7] | Electromagnetic Compatibility requirement | High | + +### 4.4.4 O-RU<sub>x</sub> Mechanical, Thermal and Power + +The mechanical, thermal and power requirements of the O-RU<sub>x</sub> are listed in Table 4-17. + +1 + +**Table 4-17: O-RU<sub>x</sub> Mechanical, Thermal and Power Requirements** + +| Parameter | Requirement | Description | Priority | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------|----------| +| Weight | 4T4R: The gross weight of the O-RU <sub>x</sub> shall be <13Kg (best estimate) | Weight requirement | High | +| | 16T16R: TBD | | Low | +| Dimension/Volume | 4T4R: The dimension of the O-RU <sub>x</sub> shall be smaller than 345x250x130 (mm) and the volume of the O-RU <sub>x</sub> shall be <12L | Dimensional Measurements | High | +| | 16T16R: TBD | | Low | +| Stability | The MTBF shall be >200000 hours | Mean Time Between Failures | High | +| Power Consumption | 4T4R: At full load, the power consumption shall not exceed 218W | Power requirement | High | +| | 16T16R: At full load, the power consumption shall not exceed TBD | | Low | +| Power supply | DC -48 VDC (-40v ~ -57v) (can be connected to AC/DC converter) or AC 220V power supply, voltage range of 140V~ 300v, frequency range of 45Hz ~ 65Hz. | Power Support Requirement | High | +| Level of protection | The protection level of the O-RU <sub>x</sub> shall be equivalent to the IP65 standard. | Protection level | High | +| Temperature and Humidity | The O-RU <sub>x</sub> shall operate at the temperature range of -40°C to +55°C with both cold start and hot start options. Humidity : 5%~95% | Ambient temperature and moisture requirement | High | +| Atmospheric pressure | The O-RU <sub>x</sub> shall operate normally under atmospheric pressure between 70 to 106Kpa. | Operational atmospheric pressure requirement | High | +| Cooling mode | Passive cooling | System cooling requirement | High | + +2 + +## 4.5 O-RU<sub>x</sub> Split Option Specific Requirements + +Besides the common requirements which shall apply to all the radio unit types. The following sections list all the specific requirements that only apply to the designated split option. + +### 4.5.1 O-RU<sub>7-2</sub> Specific Requirements + +The O-RU<sub>7-2</sub> must have one RJ45 or SFP 10G Ethernet interface used as fronthaul interface. The O-RU<sub>7-2</sub> must support the lower physical layer functions and comply with [4]. + +### 4.5.2 O-RU<sub>6</sub> Specific Requirements + +This section intentionally left blank. + +### 4.5.3 O-RU<sub>8</sub> Specific Requirements + +This section intentionally left blank. + +## 4.6 FHGW<sub>x</sub> – Common Requirements + +This section intentionally left blank. + +## 4.7 FHGW<sub>x</sub> – Split Option Specific Requirements + +This section intentionally left blank. + +## 4.8 Integrated gNB-DU Requirements + +This section intentionally left blank. + +# Annex ZZZ: O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN ALLIANCE and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN ALLIANCE that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributorship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN ALLIANCE or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the + +discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN ALLIANCE hereby grants to Adopter a nonexclusive, nontransferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an ORAN Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN ALLIANCE. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant + +Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN ALLIANCE on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of ORAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN ALLIANCE or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN ALLIANCE, and cooperates with O-RAN ALLIANCE and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN ALLIANCE's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN ALLIANCE, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the “Indemnitees”), against any liability, damage, loss, or expense (including reasonable attorneys’ fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter’s use of the licensed O-RAN Specifications or Adopter’s commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER’S BREACH OF SECTION 3, AND ADOPTER’S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED “AS IS” WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN ALLIANCE, which consent may be withheld in O-RAN ALLIANCE’s sole discretion. O-RAN ALLIANCE may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN ALLIANCE or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN ALLIANCE or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. \ No newline at end of file diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/05c823a95fefe1f4a960e3b29daafb3e_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/05c823a95fefe1f4a960e3b29daafb3e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d2532c2f1e903ff6381bb2daadfbf0bce0190c15 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/05c823a95fefe1f4a960e3b29daafb3e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0ce743bf9388874bc9dc3ea0dcf7d6a4a9181f4b7411529d41d02d1158c38f07 +size 26857 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/084f4a9c4e78cb2802c66fd20ce682b3_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/084f4a9c4e78cb2802c66fd20ce682b3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..104ddced42a9820844803b86ab7ad53036760cfc --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/084f4a9c4e78cb2802c66fd20ce682b3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e3cf651af44a9f4b675cf3acd2c95ae5b679f36776c1095e471708854027be8b +size 45783 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/25e235d77c6d1eb1f196d40689cad567_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/25e235d77c6d1eb1f196d40689cad567_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..41b06336a5531e9693c930d3a0734fc87ae2c446 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/25e235d77c6d1eb1f196d40689cad567_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c9ad2fc24b0bc6b6a8916fd0006ca759b331a7acd7853923206e1829062948f7 +size 31914 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/3c31cea4b732acd6215098d416b266ce_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/3c31cea4b732acd6215098d416b266ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..220672fe706c2b44848901fd27d71fd3b91c79fe --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/3c31cea4b732acd6215098d416b266ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f4a469f8b69bcc2a0485250f7fa7c2f6677561ae0f74e2e872776bffa2a1a295 +size 29151 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/435b6060161bc935b11eaf1554bc356b_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/435b6060161bc935b11eaf1554bc356b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..73c24cb3de2d07b74d05e16898fa0eed6e0d0391 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/435b6060161bc935b11eaf1554bc356b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ed11dec87b18d8bdcc93132f978707e8da3cf6fd5893e6d6d0d2d68d920d886 +size 4528 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/528a239c2039db243a9c2cf4150dfdcf_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/528a239c2039db243a9c2cf4150dfdcf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5238c3c546e4c8e4ba3d51e43d1a018771985335 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/528a239c2039db243a9c2cf4150dfdcf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3d2bb725dbbac3b4fe947578f3fc7f845edff2ff245261cb45c61bc15581d13c +size 37643 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/551e35d264492786d0d610557ccc1b55_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/551e35d264492786d0d610557ccc1b55_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eca96f14eff173ab5ead5b4ef80ff5827e92c33d --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/551e35d264492786d0d610557ccc1b55_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8bb0af2dd788e055159db7a05c0b9285e7d655c861421ac8dc37e4b94c3b343 +size 4454 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/6c528cfa7041c09d2320cb622ac624ce_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/6c528cfa7041c09d2320cb622ac624ce_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8b49fe0f8f0fa00f520d83714288337c9d435a09 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/6c528cfa7041c09d2320cb622ac624ce_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8e762b298678088d56099538747d23c3bf21d20a0b865a1c769e6e6c84de01a4 +size 4431 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/6f491d44cb15c50ab7a14abf688f1b03_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/6f491d44cb15c50ab7a14abf688f1b03_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f9e48cf31e8e36f29b2689a29f3c5621fae8461d --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/6f491d44cb15c50ab7a14abf688f1b03_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:920b15cc3861567b4845f24593ae20f47baf0986e68ed72d89d3d4d484891d70 +size 4432 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/76460bf5e99e0d41865041a880427922_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/76460bf5e99e0d41865041a880427922_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e8d83519c61d4ed24e9f0eebf7570d4637a826b --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/76460bf5e99e0d41865041a880427922_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:42368ea5f4a4d02d02e607cb6b3db47d3b96731faf815d4efe2e846c2128be31 +size 25656 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/87058cc45705b75b05eec495154e06b6_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/87058cc45705b75b05eec495154e06b6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3af9a1b8396bdc520cb705f0317c452f14ebba2 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/87058cc45705b75b05eec495154e06b6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d3834ca71396a387f6771e2b3c1155f1ed7e781dbdf31c42e7226694d89405d6 +size 32770 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/8d60a369f0702dc884ee5b01ff854d45_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/8d60a369f0702dc884ee5b01ff854d45_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..87434ece506652aa0b72beff9047973a3014be48 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/8d60a369f0702dc884ee5b01ff854d45_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e1420d0baf932ef02d2c3c9a803e05a140421adc273c4a4b01611a81d8de5c1 +size 171140 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..08a9c509da7e591b85ce9c11c7659f729776badc --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/9d0e6686f5161fe7bef6031a279a21c7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e51e29a8c647908fe9f48f56b660f7378772dafa9202a271bcb2032f560fafe1 +size 4531 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/b535459e6b0692d014e61f3acf918e1b_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/b535459e6b0692d014e61f3acf918e1b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1b3652a273ffb0859f06b1071fe28a4f7845658 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/b535459e6b0692d014e61f3acf918e1b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6525bf0e0351a410b9c57b442932fdfcd62efe1a5b5c6e22bb9566a49c5c21a2 +size 35288 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/bb19a24fab1cb3a2b51f82fef2ea3b61_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/bb19a24fab1cb3a2b51f82fef2ea3b61_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1e4339cbe312363fdb23b8f050547dd70447af48 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/bb19a24fab1cb3a2b51f82fef2ea3b61_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d976b7dcf50b3ae7bff9c51ec8e99373a2c9422e88bfa5330e2e6919a312e40d +size 4528 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/d0e89d3baa49c6803f5543477e999842_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/d0e89d3baa49c6803f5543477e999842_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30c08d6b5984a39927fb785d143d99112b083803 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/d0e89d3baa49c6803f5543477e999842_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a5061028eb137493f4579a22c0c45fe9acd99f9e236827eb179dd22f3e6c52e +size 4509 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2607b0eef27677fb38e9fdbba214fde5d86a7f72 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/d8c4886e05113fbb34cc3f214d1f2c09_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e9e383e92647a2356488a833110e26ad296a5dd136dd01f365e78a67474a8258 +size 4548 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/daf5732416b700788d46fbfa0d198c77_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/daf5732416b700788d46fbfa0d198c77_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6cf104d473715c619e364070bcdc13e1b42b9aea --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/daf5732416b700788d46fbfa0d198c77_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:255affe9ea6886b4e6bfb03501e125497e8f2a8b40d88acb3d5463861084c29b +size 32015 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/db41f40802b531c10dfcb105c57e1a36_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/db41f40802b531c10dfcb105c57e1a36_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4d34d58fa77025e1da97ce6d1f85731b0d50cc0f --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/db41f40802b531c10dfcb105c57e1a36_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ec8b50292745073a6779ed3d3720ba36f61e2efc361529cdc266f753d9380b0a +size 63172 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2d377a7b1ecc3d90d66455a89af93a9d69c05c2 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f53afab4ac078add52c3f0b2a3b8709940df75f38907b6df0bd3e7c4b98620ac +size 4528 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/raw.md b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..e61a929a6b889eece190938ab0ed514cdf5a94b5 --- /dev/null +++ b/marked/WG8/O-RAN.WG8.IOT.0-R004-v12.00/raw.md @@ -0,0 +1,7129 @@ + + +# --- **O-RAN Working Group 8 (Stack Reference Design)****Stack Interoperability Test Specification** + +Copyright © 2025 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +# --- Contents + +| | | +|----------------------------------------------------------|----| +| Contents..... | 2 | +| List of figures ..... | 14 | +| List of tables ..... | 15 | +| Foreword ..... | 18 | +| Modal verbs terminology ..... | 18 | +| 1 Scope..... | 18 | +| 1.1 High Level Scenarios ..... | 19 | +| 1.2 Assumptions ..... | 19 | +| 2 References..... | 20 | +| 2.1 Normative references ..... | 20 | +| 3 Definition of terms, symbols and abbreviations ..... | 22 | +| 3.1 Terms..... | 22 | +| 3.2 Symbols..... | 22 | +| 3.3 Abbreviations ..... | 22 | +| 4 General Test Conditions and Declarations..... | 24 | +| 5 Exclusions and Open Points..... | 24 | +| 6 Test Summary ..... | 25 | +| 6.1 Test Case Summary..... | 25 | +| 7 Interoperability (IOT) Standard Test Definitions ..... | 32 | +| 7.1 Interoperability Standard Test Definitions ..... | 32 | +| 7.1.1 Standard Test Configurations ..... | 32 | +| 7.1.2 DUT ..... | 32 | +| 7.1.3 Testing Tools ..... | 32 | +| 7.1.4 Time Synchronization ..... | 33 | +| 7.2 ORAN.WG8.IOT.001: Cell Setup ..... | 33 | +| 7.2.1 Test Purpose ..... | 33 | +| 7.2.2 Reference Requirements..... | 33 | +| 7.2.3 Initial Conditions ..... | 33 | +| 7.2.4 Test Setup and Configuration ..... | 33 | +| 7.2.5 Test Procedure ..... | 34 | +| 7.3 ORAN.WG8.IOT.002: SystemInformation-MIB ..... | 36 | +| 7.3.1 Test Purpose ..... | 36 | +| 7.3.2 Reference Requirements..... | 36 | +| 7.3.3 Initial Conditions ..... | 36 | +| 7.3.4 Test Setup and Configuration ..... | 37 | +| 7.3.5 Test Procedure ..... | 37 | +| 7.4 ORAN.WG8.IOT.003: Systeminformation-SIB1 ..... | 38 | +| 7.4.1 Test Purpose ..... | 38 | +| 7.4.2 Reference Requirements..... | 38 | +| 7.4.3 Initial Condition..... | 38 | +| 7.4.4 Test Setup and Configuration ..... | 38 | +| 7.4.5 Test Procedure ..... | 39 | +| 7.5 ORAN.WG8.IOT.004: Systeminformation-SIB2 ..... | 40 | +| 7.5.1 Test Purpose ..... | 40 | +| 7.5.2 Reference Requirements..... | 40 | +| 7.5.3 Initial Conditions ..... | 40 | +| 7.5.4 Test Setup and Configuration ..... | 40 | +| 7.5.5 Test Procedure ..... | 40 | +| 7.6 ORAN.WG8.IOT.005: Systeminformation-SIB3 ..... | 41 | + +| | | | +|--------|--------------------------------------------------------------------------|----| +| 7.6.1 | Test Purpose ..... | 41 | +| 7.6.2 | Reference Requirements..... | 41 | +| 7.6.3 | Initial Conditions ..... | 41 | +| 7.6.4 | Test Setup and Configuration ..... | 41 | +| 7.6.5 | Test Procedure ..... | 42 | +| 7.7 | ORAN.WG8.IOT.006: Random Access Procedure ..... | 42 | +| 7.7.1 | Test Purpose ..... | 42 | +| 7.7.2 | Reference Requirements..... | 42 | +| 7.7.3 | Initial Conditions ..... | 42 | +| 7.7.4 | Test Setup and Configuration ..... | 43 | +| 7.7.5 | Test Procedure ..... | 43 | +| 7.8 | ORAN.WG8.IOT.007: Registration Procedure ..... | 45 | +| 7.8.1 | Test Purpose ..... | 45 | +| 7.8.2 | Reference Requirements..... | 45 | +| 7.8.3 | Initial Conditions ..... | 45 | +| 7.8.4 | Test Setup and Configuration ..... | 45 | +| 7.8.5 | Test Procedure ..... | 46 | +| 7.9 | ORAN.WG8.IOT.008: UE Initiated De-Registration Procedure..... | 49 | +| 7.9.1 | Test Purpose ..... | 49 | +| 7.9.2 | Reference Requirements..... | 49 | +| 7.9.3 | Initial Conditions ..... | 49 | +| 7.9.4 | Test Setup and Configuration ..... | 49 | +| 7.9.5 | Test Procedure ..... | 50 | +| 7.10 | ORAN.WG8.IOT.009: PDU session establishment procedure..... | 51 | +| 7.10.1 | Test Purpose ..... | 51 | +| 7.10.2 | Reference Requirements..... | 51 | +| 7.10.3 | Initial Conditions ..... | 51 | +| 7.10.4 | Test Setup and Configuration ..... | 51 | +| 7.10.5 | Test Procedure ..... | 52 | +| 7.11 | ORAN.WG8.IOT.010: PDU Session Modification with Multiple Flow ..... | 53 | +| 7.11.1 | Test Purpose ..... | 53 | +| 7.11.2 | Reference Requirements..... | 53 | +| 7.11.3 | Initial Conditions ..... | 53 | +| 7.11.4 | Test Setup and Configuration ..... | 53 | +| 7.11.5 | Test Procedure ..... | 54 | +| 7.12 | ORAN.WG8.IOT.011: Idle Mode Paging and Service Request Procedure..... | 55 | +| 7.12.1 | Test Purpose ..... | 55 | +| 7.12.2 | Reference Requirements..... | 55 | +| 7.12.3 | Initial Conditions ..... | 55 | +| 7.12.4 | Test Setup and Configuration ..... | 56 | +| 7.12.5 | Test Procedure ..... | 56 | +| 7.13 | ORAN.WG8.IOT.012: Downlink UDP data transfer ..... | 58 | +| 7.13.1 | Test Purpose ..... | 58 | +| 7.13.2 | Reference Requirements..... | 58 | +| 7.13.3 | Initial Conditions ..... | 58 | +| 7.13.4 | Test Setup and Configuration ..... | 58 | +| 7.13.5 | Test Procedure ..... | 59 | +| 7.14 | ORAN.WG8.IOT.013: Uplink UDP data transfer ..... | 59 | +| 7.14.1 | Test Purpose ..... | 59 | +| 7.14.2 | Reference Requirements..... | 59 | +| 7.14.3 | Initial Condition..... | 59 | +| 7.14.4 | Test Setup and Configuration ..... | 60 | +| 7.14.5 | Test Procedure ..... | 60 | +| 7.15 | ORAN.WG8.IOT.014: Bidirectional UDP data transfer ..... | 61 | +| 7.15.1 | Test Purpose ..... | 61 | +| 7.15.2 | Reference Requirements..... | 61 | +| 7.15.3 | Initial Condition..... | 61 | +| 7.15.4 | Test Setup and Configuration ..... | 61 | +| 7.15.5 | Test Procedure ..... | 62 | +| 7.16 | ORAN.WG8.IOT.015: Bidirectional UDP data transfer on Multiple Flow ..... | 63 | +| 7.16.1 | Test Purpose ..... | 63 | + +| | | | +|--------|---------------------------------------------------------------------------------------------------------------------------------------------|----| +| 7.16.2 | Reference Requirements..... | 63 | +| 7.16.3 | Initial Conditions ..... | 63 | +| 7.16.4 | Test Setup and Configuration ..... | 63 | +| 7.16.5 | Test Procedure ..... | 64 | +| 7.17 | ORAN.WG8.IOT.016: SMO Discovery and O1 Interface establishment between O-DU and SMO using static configuration on the O-DU ..... | 65 | +| 7.17.1 | Test Purpose ..... | 65 | +| 7.17.2 | Reference Requirements..... | 66 | +| 7.17.3 | Initial Conditions ..... | 66 | +| 7.17.4 | Test Setup and Configuration ..... | 66 | +| 7.17.5 | Test Procedure ..... | 66 | +| 7.18 | ORAN.WG8.IOT.017: SMO Discovery and O1 Interface establishment between O-DU and SMO ..... | 67 | +| 7.18.1 | Test Purpose ..... | 67 | +| 7.18.2 | Reference Requirements..... | 67 | +| 7.18.3 | Initial Conditions ..... | 67 | +| 7.18.4 | Test Setup and Configuration ..... | 68 | +| 7.18.5 | Test Procedure ..... | 68 | +| 7.19 | ORAN.WG8.IOT.018: Verify the cell activation successful when configuration received from SMO for co-located O-RU and O-DU ..... | 69 | +| 7.19.1 | Test Purpose ..... | 69 | +| 7.19.2 | Reference Requirements..... | 69 | +| 7.19.3 | Initial Conditions ..... | 69 | +| 7.19.4 | Test Setup and Configuration ..... | 69 | +| 7.19.5 | Test Procedure ..... | 70 | +| 7.20 | ORAN.WG8.IOT.019: Verify the cell activation successful when configuration received from SMO for non co-located(remote) O-RU and O-DU ..... | 71 | +| 7.20.1 | Test Purpose ..... | 71 | +| 7.20.2 | Reference Requirements..... | 71 | +| 7.20.3 | Initial Conditions ..... | 71 | +| 7.20.4 | Test Setup and Configuration ..... | 72 | +| 7.20.5 | Test Procedure ..... | 72 | +| 7.21 | ORAN.WG8.IOT.020: Verify SMO is notified with the alarm when O-DU detects out of sync from O-RU in hierarchical model. .... | 74 | +| 7.21.1 | Test Purpose ..... | 74 | +| 7.21.2 | Reference Requirements..... | 74 | +| 7.21.3 | Initial Conditions ..... | 74 | +| 7.21.4 | Test Setup and Configuration ..... | 74 | +| 7.21.5 | Test Procedure ..... | 75 | +| 7.22 | ORAN.WG8.IOT.021: Verify SMO sends subscription to O-RU via O-DU for alarms and handles the alarm notification from O-RU via O-DU ..... | 76 | +| 7.22.1 | Test Purpose ..... | 76 | +| 7.22.2 | Reference Requirements..... | 77 | +| 7.22.3 | Initial Conditions ..... | 77 | +| 7.22.4 | Test Setup and Configuration ..... | 77 | +| 7.22.5 | Test Procedure ..... | 78 | +| 7.23 | ORAN.WG8.IOT.022: Verify SMO handles any subscribed measurement counters received from O-DU on O1 interface. .... | 78 | +| 7.23.1 | Test Purpose ..... | 78 | +| 7.23.2 | Reference Requirements..... | 78 | +| 7.23.3 | Initial Conditions ..... | 78 | +| 7.23.4 | Test Setup and Configuration ..... | 79 | +| 7.23.5 | Test Procedure ..... | 79 | +| 7.24 | ORAN.WG8.IOT.023: Verify O-DU successfully establish E2 Interface with near RT-RIC. .... | 80 | +| 7.24.1 | Test Purpose ..... | 80 | +| 7.24.2 | Reference Requirements..... | 80 | +| 7.24.3 | Initial Conditions ..... | 80 | +| 7.24.4 | Test Setup and Configuration ..... | 81 | +| 7.24.5 | Test Procedure ..... | 81 | +| 7.25 | ORAN.WG8.IOT.024: Verify near RT-RIC server sends subscription request with type as REPORT to O-DU..... | 82 | +| 7.25.1 | Test Purpose ..... | 82 | + +| | | | +|--------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| 7.25.2 | Reference Requirements..... | 82 | +| 7.25.3 | Initial Conditions ..... | 82 | +| 7.25.4 | Test Setup and Configuration ..... | 82 | +| 7.25.5 | Test Procedure ..... | 83 | +| 7.26 | ORAN.WG8.IOT.025: Verify O-DU includes the RIC Actions Not Admitted List in subscription response to near RT-RIC server. .... | 83 | +| 7.26.1 | Test Purpose ..... | 83 | +| 7.26.2 | Reference Requirements..... | 84 | +| 7.26.3 | Initial Conditions ..... | 84 | +| 7.26.4 | Test Setup and Configuration ..... | 84 | +| 7.26.5 | Test Procedure ..... | 85 | +| 7.27 | ORAN.WG8.IOT.026: Verify O-DU sends periodic report to the subscribed features to near RT-RIC server. .... | 85 | +| 7.27.1 | Test Purpose ..... | 85 | +| 7.27.2 | Reference Requirements..... | 85 | +| 7.27.3 | Initial Conditions ..... | 85 | +| 7.27.4 | Test Setup and Configuration ..... | 86 | +| 7.27.5 | Test Procedure ..... | 87 | +| 7.28 | ORAN.WG8.IOT.027: Verify UE attach is successful with the given SSB periodicity and sub-carrier spacing as part of cell configuration structure from SMO to O-DU for FR1 configuration. .... | 87 | +| 7.28.1 | Test Purpose ..... | 87 | +| 7.28.2 | Reference Requirements..... | 87 | +| 7.28.3 | Initial Conditions ..... | 87 | +| 7.28.4 | Test Setup and Configuration ..... | 88 | +| 7.28.5 | Test Procedure..... | 88 | +| 7.29 | ORAN.WG8.IOT.028: Verify UE attach is successful with Transmission periodicity configured to ms2p5 for FR1 configuration. .... | 90 | +| 7.29.1 | Test Purpose ..... | 90 | +| 7.29.2 | Reference Requirements..... | 90 | +| 7.29.3 | Initial Conditions ..... | 90 | +| 7.29.4 | Test Setup and Configuration ..... | 90 | +| 7.29.5 | Test Procedure ..... | 91 | +| 7.30 | ORAN.WG8.IOT.029: Verify UE attach is successful with Transmission periodicity configured to ms5 for FR1 configuration. .... | 92 | +| 7.30.1 | Test Purpose ..... | 92 | +| 7.30.2 | Reference Requirements..... | 92 | +| 7.30.3 | Initial Conditions ..... | 92 | +| 7.30.4 | Test Setup and Configuration ..... | 93 | +| 7.30.5 | Test Procedure ..... | 93 | +| 7.31 | ORAN.WG8.IOT.030: Verify cell bring up is successful with 100Mhz bandwidth configuration received from SMO for FR1 configuration. .... | 94 | +| 7.31.1 | Test Purpose ..... | 94 | +| 7.31.2 | Reference Requirements..... | 94 | +| 7.31.3 | Initial Conditions ..... | 94 | +| 7.31.4 | Test Setup and Configuration ..... | 95 | +| 7.31.5 | Test Procedure ..... | 95 | +| 7.32 | ORAN.WG8.IOT.031: Verify DL and UL scheduling information IE's during an end-to-end UDP FDX data transmission for FR1 configuration. .... | 96 | +| 7.32.1 | Test Purpose ..... | 96 | +| 7.32.2 | Reference Requirements..... | 96 | +| 7.32.3 | Initial Condition..... | 97 | +| 7.32.4 | Test Setup and Configuration ..... | 97 | +| 7.32.5 | Test Procedure ..... | 98 | +| 7.33 | ORAN.WG8.IOT.032: Verify cell bring up is successful with 64 beams and 64 antenna ports configuration received from SMO to O-DU for FR2 configuration. .... | 100 | +| 7.33.1 | Test Purpose ..... | 100 | +| 7.33.2 | Reference Requirements..... | 100 | +| 7.33.3 | Initial Condition..... | 100 | +| 7.33.4 | Test Setup and Configuration ..... | 100 | +| 7.33.5 | Test Procedure ..... | 101 | + +| | | | +|--------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| 7.34 | ORAN.WG8.IOT.033: Verify cell bring up is successful with 8 beams and 64 antenna ports configuration received from SMO to O-DU for FR1 configuration. .... | 102 | +| 7.34.1 | Test Purpose ..... | 102 | +| 7.34.2 | Reference Requirements..... | 102 | +| 7.34.3 | Initial Condition..... | 103 | +| 7.34.4 | Test Setup and Configuration..... | 103 | +| 7.34.5 | Test Procedure ..... | 104 | +| 7.35 | ORAN.WG8.IOT.034: Verify cell bring up is successful and UE attach when the O-DU is configured with 32 punctured SSB beams for FR2 configuration. .... | 105 | +| 7.35.1 | Test Purpose ..... | 105 | +| 7.35.2 | Reference Requirements..... | 105 | +| 7.35.3 | Initial Conditions ..... | 105 | +| 7.35.4 | Test Setup and Configuration..... | 105 | +| 7.35.5 | Test Procedure ..... | 106 | +| 7.36 | ORAN.WG8.IOT.035: Verify cell bring up is successful when the parameter Occasion And CB-Preambles per SSB is configured to 1 by SMO for FR1 configuration. .... | 107 | +| 7.36.1 | Test Purpose ..... | 107 | +| 7.36.2 | Reference Requirements..... | 107 | +| 7.36.3 | Initial Conditions ..... | 108 | +| 7.36.4 | Test Setup and Configuration..... | 108 | +| 7.36.5 | Test Procedure ..... | 109 | +| 7.37 | ORAN.WG8.IOT.036: Verify the successful cell activation when slice specific configuration containing list of slices in the TA per PLMN is sent towards MAC/SCH on the O1 interface. .... | 111 | +| 7.37.1 | Test Purpose ..... | 111 | +| 7.37.2 | Reference Requirements..... | 111 | +| 7.37.3 | Initial Conditions ..... | 111 | +| 7.37.4 | Test Setup and Configuration..... | 111 | +| 7.37.5 | Test Procedure ..... | 112 | +| 7.38 | ORAN.WG8.IOT.037: Verify UE Registration and PDU session establishment procedure with an allowed S-NSSAI. .... | 114 | +| 7.38.1 | Test Purpose ..... | 114 | +| 7.38.2 | Reference Requirements..... | 114 | +| 7.38.3 | Initial Conditions ..... | 114 | +| 7.38.4 | Test Setup and Configuration..... | 114 | +| 7.38.5 | Test Procedure ..... | 115 | +| 7.39 | ORAN.WG8.IOT.038: Verify downlink data prioritization/scheduling on basis of slice differentiation in-case of each UE with single PDU session per slice. .... | 119 | +| 7.39.1 | Test Purpose ..... | 119 | +| 7.39.2 | Reference Requirements..... | 119 | +| 7.39.3 | Initial Conditions ..... | 120 | +| 7.39.4 | Test Setup and Configuration..... | 120 | +| 7.39.5 | Test Procedure ..... | 121 | +| 7.40 | ORAN.WG8.IOT.039: Verify downlink data scheduling on basis of QoS flow prioritization when two PDU sessions have equal slice priority. .... | 121 | +| 7.40.1 | Test Purpose ..... | 121 | +| 7.40.2 | Reference Requirements..... | 122 | +| 7.40.3 | Initial Conditions ..... | 122 | +| 7.40.4 | Test Setup and Configuration..... | 122 | +| 7.40.5 | Test Procedure ..... | 122 | +| 7.41 | ORAN.WG8.IOT.040: Verify key performance metrics with the sub-counters at S-NSSAI level.. | 123 | +| 7.41.1 | Test Purpose ..... | 123 | +| 7.41.2 | Reference Requirements..... | 123 | +| 7.41.3 | Initial Conditions ..... | 123 | +| 7.41.4 | Test Setup and Configuration..... | 124 | +| 7.41.5 | Test Procedure ..... | 124 | +| 7.42 | ORAN.WG8.IOT.041: Verify successful slice re-configuration when RRM Policy is updated on the O1 interface. .... | 125 | +| 7.42.1 | Test Purpose ..... | 125 | +| 7.42.2 | Reference Requirements..... | 125 | +| 7.42.3 | Initial Conditions ..... | 125 | +| 7.42.4 | Test Setup and Configuration..... | 125 | + +| | | | +|--------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| 7.42.5 | Test Procedure ..... | 126 | +| 7.43 | ORAN.WG8.IOT.042: Verify slice reconfiguration failure in-case of incorrect S-NSSAI is updated on the O1 interface. .... | 127 | +| 7.43.1 | Test Purpose ..... | 127 | +| 7.43.2 | Reference Requirements..... | 127 | +| 7.43.3 | Initial Conditions ..... | 127 | +| 7.43.4 | Test Setup and Configuration ..... | 127 | +| 7.43.5 | Test Procedure ..... | 128 | +| 7.44 | ORAN.WG8.IOT.043: Verify cell activation when O-DU is receiving synchronization from external timing source and sync-state is locked..... | 128 | +| 7.44.1 | Test Purpose ..... | 128 | +| 7.44.2 | Reference Requirements..... | 128 | +| 7.44.3 | Initial Conditions ..... | 129 | +| 7.44.4 | Test Setup and Configuration ..... | 129 | +| 7.44.5 | Test Procedure ..... | 130 | +| 7.45 | ORAN.WG8.IOT.044: Verify cell activation when O-DU is receiving synchronization from external timing source and sync-state is not locked..... | 131 | +| 7.45.1 | Test Purpose ..... | 131 | +| 7.45.2 | Reference Requirements..... | 131 | +| 7.45.3 | Initial Conditions ..... | 131 | +| 7.45.4 | Test Setup and Configuration ..... | 132 | +| 7.45.5 | Test Procedure ..... | 132 | +| 7.46 | ORAN.WG8.IOT.045: Verify cell activation when O-DU is receiving synchronization from external timing source and sync-state transits from locked to holdover and freerun..... | 133 | +| 7.46.1 | Test Purpose ..... | 133 | +| 7.46.2 | Reference Requirements..... | 133 | +| 7.46.3 | Initial Conditions ..... | 133 | +| 7.46.4 | Test Setup and Configuration ..... | 134 | +| 7.46.5 | Test Procedure ..... | 134 | +| 7.47 | ORAN.WG8.IOT.046: Verify cell activation when O-DU successfully receive synchronization from secondary source when sync fails with the primary source. .... | 136 | +| 7.47.1 | Test Purpose ..... | 136 | +| 7.47.2 | Reference Requirements..... | 137 | +| 7.47.3 | Initial Conditions ..... | 137 | +| 7.47.4 | Test Setup and Configuration ..... | 137 | +| 7.47.5 | Test Procedure ..... | 138 | +| 7.48 | ORAN.WG8.IOT.047: Verify O-CU and O-DU provisions HO configuration sent over O1 interface by SMO for inter-O-DU handover within an O-CU ..... | 139 | +| 7.48.1 | Test Purpose ..... | 139 | +| 7.48.2 | Reference Requirement ..... | 139 | +| 7.48.3 | Initial Conditions ..... | 140 | +| 7.48.4 | Test Setup and Configuration ..... | 140 | +| 7.48.5 | Test Procedure ..... | 141 | +| 7.49 | ORAN.WG8.IOT.048: Verify successful Intra frequency measurement based inter-O-DU handover within an O-CU ..... | 141 | +| 7.49.1 | Test Purpose ..... | 141 | +| 7.49.2 | Reference Requirement ..... | 141 | +| 7.49.3 | Initial Conditions ..... | 141 | +| 7.49.4 | Test Setup and Configuration ..... | 142 | +| 7.49.5 | Test Procedure ..... | 142 | +| 7.50 | ORAN.WG8.IOT.049: Verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having single QFI established..... | 144 | +| 7.50.1 | Test Purpose ..... | 144 | +| 7.50.2 | Reference Requirement ..... | 145 | +| 7.50.3 | Initial Conditions ..... | 145 | +| 7.50.4 | Test Setup and Configuration ..... | 145 | +| 7.50.5 | Test Procedure ..... | 146 | +| 7.51 | ORAN.WG8.IOT.050: Verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having multiple QFI established where few PDU sessions are admitted at target DU..... | 148 | + +| | | | +|--------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| 7.51.1 | Test Purpose ..... | 148 | +| 7.51.2 | Reference Requirement ..... | 148 | +| 7.51.3 | Initial Conditions ..... | 148 | +| 7.51.4 | Test Setup and Configuration ..... | 148 | +| 7.51.5 | Test Procedure ..... | 149 | +| 7.52 | ORAN.WG8.IOT.051: Verify successful inter frequency measurement based inter-O-DU handover within an O-CU ..... | 151 | +| 7.52.1 | Test Purpose ..... | 151 | +| 7.52.2 | Reference Requirement ..... | 151 | +| 7.52.3 | Initial Conditions ..... | 151 | +| 7.52.4 | Test Setup and Configuration ..... | 152 | +| 7.52.5 | Test Procedure ..... | 152 | +| 7.53 | ORAN.WG8.IOT.052: Verify HO preparation failure at target O-DU during inter-O-DU handover within an O-CU ..... | 154 | +| 7.53.1 | Test Purpose ..... | 154 | +| 7.53.2 | Reference Requirement ..... | 154 | +| 7.53.3 | Initial Conditions ..... | 154 | +| 7.53.4 | Test Setup and Configuration ..... | 155 | +| 7.53.5 | Test Procedure ..... | 155 | +| 7.54 | ORAN.WG8.IOT.053: Verify RRC Re-establishment received at O-CU when HO execution fails during inter-O-DU handover within an O-CU ..... | 157 | +| 7.54.1 | Test Purpose ..... | 157 | +| 7.54.2 | Reference Requirement ..... | 157 | +| 7.54.3 | Initial Conditions ..... | 157 | +| 7.54.4 | Test Setup and Configuration ..... | 157 | +| 7.54.5 | Test Procedure ..... | 158 | +| 7.55 | ORAN.WG8.IOT.054: Verify beam failure detection and recovery using SSB for detection as well as recovery with DRX disabled and 64 beams for FR2 configuration. .... | 161 | +| 7.55.1 | Test Purpose ..... | 161 | +| 7.55.2 | Reference Requirements..... | 161 | +| 7.55.3 | Initial Condition..... | 161 | +| 7.55.4 | Test Setup and Configuration ..... | 161 | +| 7.55.5 | Test Procedure ..... | 162 | +| 7.56 | ORAN.WG8.IOT.055: Verify beam failure detection and recovery using SSB for detection as well as recovery with DRX disabled and 8 beams for FR1 configuration. .... | 164 | +| 7.56.1 | Test Purpose ..... | 164 | +| 7.56.2 | Reference Requirements..... | 164 | +| 7.56.3 | Initial Condition..... | 164 | +| 7.56.4 | Test Setup and Configuration ..... | 164 | +| 7.56.5 | Test Procedure ..... | 165 | +| 7.57 | ORAN.WG8.IOT.056: Verify beam failure detection and recovery using SSB for detection as well as recovery with DRX enabled and 8 beams for FR1 configuration. .... | 167 | +| 7.57.1 | Test Purpose ..... | 167 | +| 7.57.2 | Reference Requirements..... | 167 | +| 7.57.3 | Initial Condition..... | 167 | +| 7.57.4 | Test Setup and Configuration ..... | 168 | +| 7.57.5 | Test Procedure ..... | 168 | +| 7.58 | ORAN.WG8.IOT.057: Verify beam failure detection and recovery using CSI-RS for detection as well as recovery with DRX disabled and 32 beams for FR2 configuration. .... | 170 | +| 7.58.1 | Test Purpose ..... | 170 | +| 7.58.2 | Reference Requirements..... | 171 | +| 7.58.3 | Initial Condition..... | 171 | +| 7.58.4 | Test Setup and Configuration ..... | 171 | +| 7.58.5 | Test Procedure ..... | 172 | +| 7.59 | ORAN.WG8.IOT.058: Verify prioritized random access during beam failure recovery ..... | 173 | +| 7.59.1 | Test Purpose ..... | 173 | +| 7.59.2 | Reference Requirements..... | 173 | +| 7.59.3 | Initial Condition..... | 174 | +| 7.59.4 | Test Setup and Configuration ..... | 174 | +| 7.59.5 | Test Procedure ..... | 175 | + +| | | | +|--------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| 7.60 | ORAN.WG8.IOT.059: Verify beam failure detection and recovery when SSB/CSI-RS not configured under radioLinkMonitoringConfig. .... | 177 | +| 7.60.1 | Test Purpose ..... | 177 | +| 7.60.2 | Reference Requirements..... | 177 | +| 7.60.3 | Initial Condition..... | 177 | +| 7.60.4 | Test Setup and Configuration..... | 177 | +| 7.60.5 | Test Procedure ..... | 178 | +| 7.61 | ORAN.WG8.IOT.060: Verify end-to-end data with different CSI-RS configuration..... | 180 | +| 7.61.1 | Test Purpose ..... | 180 | +| 7.61.2 | Reference Requirements..... | 180 | +| 7.61.3 | Initial Condition..... | 180 | +| 7.61.4 | Test Setup and Configuration ..... | 181 | +| 7.61.5 | Test Procedure ..... | 181 | +| 7.62 | ORAN.WG8.IOT.061: Verify cell bring up is not successful with invalid configuration received from SMO ..... | 182 | +| 7.62.1 | Test Purpose ..... | 182 | +| 7.62.2 | Reference Requirements..... | 182 | +| 7.62.3 | Initial Condition..... | 182 | +| 7.62.4 | Test Setup and Configuration ..... | 183 | +| 7.62.5 | Test Procedure ..... | 183 | +| 7.63 | ORAN.WG8.IOT.062: Verify end-to-end data when SRS is enabled and UE is in mobility ..... | 184 | +| 7.63.1 | Test Purpose ..... | 184 | +| 7.63.2 | Reference Requirements..... | 184 | +| 7.63.3 | Initial Condition..... | 184 | +| 7.63.4 | Test Setup and Configuration..... | 185 | +| 7.63.5 | Test Procedure ..... | 185 | +| 7.64 | ORAN.WG8.IOT.063: Verify successful collection and transfer of MAC statistics for MU-MIMO from O-DU-OAM-Agent to SMO..... | 186 | +| 7.64.1 | Test Purpose ..... | 186 | +| 7.64.2 | Reference Requirement ..... | 186 | +| 7.64.3 | Initial Conditions ..... | 186 | +| 7.64.4 | Test Setup and Configuration..... | 187 | +| 7.64.5 | Test Procedure ..... | 187 | +| 7.65 | ORAN.WG8.IOT.064: Verify O-DU-OAM-Agent successfully download the configuration from SMO for beamforming optimization through "file-download request". .... | 189 | +| 7.65.1 | Test Purpose ..... | 189 | +| 7.65.2 | Reference Requirement ..... | 189 | +| 7.65.3 | Initial Conditions ..... | 189 | +| 7.65.4 | Test Setup and Configuration..... | 190 | +| 7.65.5 | Test Procedure ..... | 190 | +| 7.66 | ORAN.WG8.IOT.065: Verify successful collection and transfer of L1 measurements along with parameter reconfiguration for AI/ML assisted Beam Selection Optimization on E2 interface. .... | 193 | +| 7.66.1 | Test Purpose ..... | 193 | +| 7.66.2 | Reference Requirement ..... | 193 | +| 7.66.3 | Initial Conditions ..... | 193 | +| 7.66.4 | Test Setup and Configuration..... | 194 | +| 7.66.5 | Test Procedure ..... | 194 | +| 7.67 | ORAN.WG8.IOT.066: Verify successful vO-DU and vO-CU deployment on an O-Cloud. .... | 197 | +| 7.67.1 | Test Purpose ..... | 197 | +| 7.67.2 | Reference Requirement ..... | 197 | +| 7.67.3 | Initial Conditions ..... | 197 | +| 7.67.4 | Test Setup and Configuration..... | 197 | +| 7.67.5 | Test Procedure ..... | 198 | +| 7.68 | ORAN.WG8.IOT.067: Verify successful addition of vO-DU and vO-CU instance when network demand increases beyond current NF capacity threshold. .... | 200 | +| 7.68.1 | Test Purpose ..... | 200 | +| 7.68.2 | Reference Requirement ..... | 201 | +| 7.68.3 | Initial Conditions ..... | 201 | +| 7.68.4 | Test Setup and Configuration..... | 201 | +| 7.68.5 | Test Procedure ..... | 202 | + +| | | | +|--------|-------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| 7.69 | ORAN.WG8.IOT.068: Verify successful deletion of vO-DU and vO-CU instance when network demand reduces below NF capacity threshold. .... | 203 | +| 7.69.1 | Test Purpose ..... | 203 | +| 7.69.2 | Reference Requirement ..... | 204 | +| 7.69.3 | Initial Conditions ..... | 204 | +| 7.69.4 | Test Setup and Configuration ..... | 204 | +| 7.69.5 | Test Procedure ..... | 205 | +| 7.70 | ORAN.WG8.IOT.069: Verify successful software upgrade for vO-DU ..... | 206 | +| 7.70.1 | Test Purpose ..... | 206 | +| 7.70.2 | Reference Requirement ..... | 206 | +| 7.70.3 | Initial Conditions ..... | 206 | +| 7.70.4 | Test Setup and Configuration ..... | 206 | +| 7.70.5 | Test Procedure ..... | 207 | +| 7.71 | ORAN.WG8.IOT.070: Verify successful reconfiguration for vO-DU ..... | 208 | +| 7.71.1 | Test Purpose ..... | 208 | +| 7.71.2 | Reference Requirement ..... | 208 | +| 7.71.3 | Initial Conditions ..... | 209 | +| 7.71.4 | Test Setup and Configuration ..... | 209 | +| 7.71.5 | Test Procedure ..... | 210 | +| 7.72 | ORAN.WG8.IOT.071: Verify vO-DU functionality during PTP sync loss and recovery ..... | 211 | +| 7.72.1 | Test Purpose ..... | 211 | +| 7.72.2 | Reference Requirement ..... | 211 | +| 7.72.3 | Initial Conditions ..... | 211 | +| 7.72.4 | Test Setup and Configuration ..... | 212 | +| 7.72.5 | Test Procedure ..... | 212 | +| 7.73 | ORAN.WG8.IOT.072: Verification of SSH/ TLS version compatibility of secured NETCONF session creation at O1 interface and fronthaul interface. .... | 214 | +| 7.73.1 | Test Purpose ..... | 214 | +| 7.73.2 | Reference Requirement ..... | 214 | +| 7.73.3 | Initial Conditions ..... | 214 | +| 7.73.4 | Test Setup and Configuration ..... | 214 | +| 7.73.5 | Test Procedure ..... | 215 | +| 7.74 | ORAN.WG8.IOT.073: Verification of successful secured NETCONF session creation over SSH/ TLS channel at the O1 interface and fronthaul interface. .... | 217 | +| 7.74.1 | Test Purpose ..... | 217 | +| 7.74.2 | Reference Requirement ..... | 217 | +| 7.74.3 | Initial Conditions ..... | 217 | +| 7.74.4 | Test Setup and Configuration ..... | 217 | +| 7.74.5 | Test Procedure ..... | 218 | +| 7.75 | ORAN.WG8.IOT.074: Verification of Access Control Groups defined for NETCONF sessions created at O1 interface and fronthaul interface. .... | 220 | +| 7.75.1 | Test Purpose ..... | 220 | +| 7.75.2 | Reference Requirement ..... | 221 | +| 7.75.3 | Initial Conditions ..... | 221 | +| 7.75.4 | Test Setup and Configuration ..... | 221 | +| 7.75.5 | Test Procedure ..... | 222 | +| 7.76 | ORAN.WG8.IOT.075: Verify cell bring up using GoB configuration received from SMO is successful. .... | 223 | +| 7.76.1 | Test Purpose ..... | 223 | +| 7.76.2 | Reference Requirement ..... | 224 | +| 7.76.3 | Initial Conditions ..... | 224 | +| 7.76.4 | Test Setup and Configuration ..... | 224 | +| 7.76.5 | Test Procedure ..... | 225 | +| 7.77 | ORAN.WG8.IOT.076: Verify successful AI/ML-assisted non-GoB beamforming optimization in Near RT RIC. .... | 226 | +| 7.77.1 | Test Purpose ..... | 226 | +| 7.77.2 | Reference Requirement ..... | 226 | +| 7.77.3 | Initial Conditions ..... | 226 | +| 7.77.4 | Test Setup and Configuration ..... | 227 | +| 7.77.5 | Test Procedure ..... | 227 | + +| | | | +|--------|---------------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| 7.78 | ORAN.WG8.IOT.077: Verify successful cell bring-up of Shared O-RU in Single operator deployment..... | 230 | +| 7.78.1 | Test Purpose ..... | 230 | +| 7.78.2 | Reference Requirement ..... | 230 | +| 7.78.3 | Initial Conditions ..... | 230 | +| 7.78.4 | Test Setup and Configuration ..... | 231 | +| 7.78.5 | Test Procedure ..... | 231 | +| 7.79 | ORAN.WG8.IOT.078: Verify successful detection for supervision failure of Shared O-RU in Single operator deployment..... | 233 | +| 7.79.1 | Test Purpose ..... | 233 | +| 7.79.2 | Reference Requirement ..... | 233 | +| 7.79.3 | Initial Conditions ..... | 233 | +| 7.79.4 | Test Setup and Configuration ..... | 234 | +| 7.79.5 | Test Procedure ..... | 234 | +| 7.80 | ORAN.WG8.IOT.079: Verify successful performance management of a Shared O-RU in Single operator deployment..... | 235 | +| 7.80.1 | Test Purpose ..... | 235 | +| 7.80.2 | Reference Requirement ..... | 235 | +| 7.80.3 | Initial Conditions ..... | 235 | +| 7.80.4 | Test Setup and Configuration ..... | 236 | +| 7.80.5 | Test Procedure ..... | 237 | +| 7.81 | ORAN.WG8.IOT.080: Verify successful switchover from active to standby O-DU node in Single operator deployment..... | 238 | +| 7.81.1 | Test Purpose ..... | 238 | +| 7.81.2 | Reference Requirement ..... | 238 | +| 7.81.3 | Initial Conditions ..... | 238 | +| 7.81.4 | Test Setup and Configuration ..... | 239 | +| 7.81.5 | Test Procedure ..... | 240 | +| 7.82 | ORAN.WG8.IOT.081: Verify successful scale-out operation for a O-DU node by the SMO in Single operator deployment..... | 241 | +| 7.82.1 | Test Purpose ..... | 241 | +| 7.82.2 | Reference Requirement ..... | 241 | +| 7.82.3 | Initial Conditions ..... | 241 | +| 7.82.4 | Test Setup and Configuration ..... | 242 | +| 7.82.5 | Test Procedure ..... | 242 | +| 7.83 | ORAN.WG8.IOT.082: Verify successful software upgrade for O-RU triggered by O-DU..... | 244 | +| 7.83.1 | Test Purpose ..... | 244 | +| 7.83.2 | Reference Requirement ..... | 244 | +| 7.83.3 | Initial Conditions ..... | 244 | +| 7.83.4 | Test Setup and Configuration ..... | 245 | +| 7.83.5 | Test Procedure ..... | 245 | +| 7.84 | ORAN.WG8.IOT.083: Verify successful configuration and data header compression/de-compression at O-CU when RoHC profile “0x0001” is used for “RTP/UDP/IP”..... | 246 | +| 7.84.1 | Test Purpose ..... | 246 | +| 7.84.2 | Reference Requirements..... | 246 | +| 7.84.3 | Initial Conditions ..... | 246 | +| 7.84.4 | Test Setup and Configuration ..... | 247 | +| 7.84.5 | Test Procedure ..... | 247 | +| 7.85 | ORAN.WG8.IOT.084: Verify successful configuration and data header compression/de-compression at O-CU when RoHC profile “0x0002” is used for “UDP/IP”. ..... | 254 | +| 7.85.1 | Test Purpose ..... | 254 | +| 7.85.2 | Reference Requirements..... | 254 | +| 7.85.3 | Initial Conditions ..... | 254 | +| 7.85.4 | Test Setup and Configuration ..... | 255 | +| 7.85.5 | Test Procedure ..... | 255 | +| 7.86 | ORAN.WG8.IOT.085: Verify successful collection and transfer of slice performance reports via E2 interface..... | 260 | +| 7.86.1 | Test Purpose ..... | 260 | +| 7.86.2 | Reference Requirement ..... | 260 | +| 7.86.3 | Initial Conditions ..... | 260 | +| 7.86.4 | Test Setup and Configuration ..... | 260 | + +| | | | +|---------------------------------|--------------------------------------------------------------------------------------------------------------------------------|-----| +| 7.86.5 | Test Procedure ..... | 261 | +| 7.87 | ORAN.WG8.IOT.086: Verify successful policy delivery and execution of slice reconfiguration via E2 interface. .... | 262 | +| 7.87.1 | Test Purpose ..... | 262 | +| 7.87.2 | Reference Requirement ..... | 262 | +| 7.87.3 | Initial Conditions ..... | 262 | +| 7.87.4 | Test Setup and Configuration ..... | 263 | +| 7.87.5 | Test Procedure ..... | 263 | +| 7.88 | ORAN.WG8.IOT.087: Verify successful UE registration and data transmission in a Shared O-RU multi-vendor slice deployment. .... | 265 | +| 7.88.1 | Test Purpose ..... | 265 | +| 7.88.2 | Reference Requirement ..... | 266 | +| 7.88.3 | Initial Conditions ..... | 266 | +| 7.88.4 | Test Setup and Configuration ..... | 266 | +| 7.88.5 | Test Procedure ..... | 267 | +| 7.89 | ORAN.WG8.IOT.088: Verify network energy saving functionality in TRX_CONTROL mode configured with undefined Sleep Period. .... | 269 | +| 7.89.1 | Test Purpose ..... | 269 | +| 7.89.2 | Reference Requirement ..... | 269 | +| 7.89.3 | Initial Conditions ..... | 269 | +| 7.89.4 | Test Setup and Configuration ..... | 270 | +| 7.89.5 | Test Procedure ..... | 270 | +| 7.90 | ORAN.WG8.IOT.089: Verify network energy saving functionality in TRX_CONTROL mode configured with defined Sleep Period. .... | 274 | +| 7.90.1 | Test Purpose ..... | 274 | +| 7.90.2 | Reference Requirement ..... | 274 | +| 7.90.3 | Initial Conditions ..... | 274 | +| 7.90.4 | Test Setup and Configuration ..... | 275 | +| 7.90.5 | Test Procedure ..... | 275 | +| Annex A | (informative) ..... | 278 | +| Test Setup | 278 | | +| A.1 | Test Setup 1: End to End OTA architecture using commercial UE ..... | 278 | +| A.2 | Test Setup 2: End to End OTA architecture using UE Simulator/Emulator ..... | 279 | +| A.3 | Test Setup 3: Simulated CU and CN architecture ..... | 279 | +| A.4 | Test Setup 4: O1 and E2 interface for Remote O-RU connected to O-DU architecture ..... | 279 | +| A.5 | Test Setup 5: O1 and E2 interface for co-located O-RU and O-DU architecture ..... | 280 | +| A.6 | Test Setup 6: Setup for inter O-DU HO within an O-CU ..... | 280 | +| A.7 | Test Setup 7: Setup for O-DU Timing Synchronization ..... | 280 | +| A.8 | Test Setup 8: Setup for vO-DU and vO-CU Cloudification ..... | 281 | +| A.9 | Test Setup 9: Setup for Single Operator Solution for Shared O-RU ..... | 281 | +| Annex B | (informative) ..... | 282 | +| Test Profile 1: Throughput Test | 282 | | +| B.1 | FTP Settings ..... | 282 | +| B.1.1 | UDP Settings ..... | 282 | +| B.2 | MIB and SSB configuration ..... | 282 | +| B.2.1 | MIB and SSB for FR1 ..... | 282 | +| B.2.2 | MIB and SSB for FR2 ..... | 283 | +| B.3 | SIB1 Configuration ..... | 284 | +| B.4 | PUCCH Support- Short PUCCH Format Configuration ..... | 284 | +| B.5 | Downlink Data Delivery Status Reporting ..... | 285 | +| B.6 | RACH Configuration ..... | 286 | +| B.7 | Throughput Configuration ..... | 286 | +| B.8 | CSI-RS configuration ..... | 287 | +| B.9 | SRS configuration ..... | 287 | +| B.10 | IMS Settings ..... | 288 | + +| | | +|------------------------------|-----| +| Annex C (informative)..... | 289 | +| C.1 Initial Access Flow..... | 289 | +| Revision History..... | 290 | + +--- + +## List of figures + +| | | +|--------------------------------------------------------------------------------------------------------|-----| +| FIGURE 7.1.2-A: DUT CONFIGURATION ..... | 32 | +| FIGURE A.1- 1: TEST SETUP 1 - END TO END OTA ARCHITECTURE USING COMMERCIAL UE ..... | 278 | +| FIGURE A.2- 1: TEST SETUP 2 - END TO END OTA ARCHITECTURE USING UE SIMULATOR/EMULATOR ..... | 279 | +| FIGURE A.3- 1: TEST SETUP 3 - SIMULATED CU AND CN ARCHITECTURE ..... | 279 | +| FIGURE A.4- 1: TEST SETUP 4 - O1 AND E2 INTERFACE FOR REMOTE O-RU CONNECTED TO O-DU ARCHITECTURE ..... | 279 | +| FIGURE A.5- 1: TEST SETUP 5 - O1 AND E2 INTERFACE FOR CO-LOCATED O-RU AND O-DU ARCHITECTURE ..... | 280 | +| FIGURE A.6- 1: TEST SETUP 6 - INTER O-DU HO WITHIN AN O-CU ..... | 280 | +| FIGURE A.7- 1: TEST SETUP 7 – O-DU TIMING SYNCHRONIZATION ..... | 280 | +| FIGURE A.8- 1: TEST SETUP 8 – VO-DU AND VO-CU CLOUDIFICATION ..... | 281 | + +# List of tables + +| | | +|---------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| TABLE 6.1-1: TEST SUMMARY ..... | 25 | +| TABLE 7.2-1: CELL SETUP ..... | 34 | +| TABLE 7.3-1: SYSTEMINFORMATION-MIB..... | 37 | +| TABLE 7.4-1: SYSTEMINFORMATION-SIB1 ..... | 39 | +| TABLE 7.5-1: SYSTEMINFORMATION-SIB2 ..... | 40 | +| TABLE 7.6-1: SYSTEMINFORMATION-SIB3 ..... | 42 | +| TABLE 7.7-1: RANDOM ACCESS PROCEDURE..... | 43 | +| TABLE 7.8-1: REGISTRATION ..... | 46 | +| TABLE 7.9-1: UE INITIATED DE-REGISTRATION ..... | 50 | +| TABLE 7.10-1: PDU SESSION ESTABLISHMENT ..... | 52 | +| TABLE 7.11-1: PDU SESSION MODIFICATION ..... | 54 | +| TABLE 7.12-1: IDLE MODE PAGING & SERVICE REQUEST ..... | 56 | +| TABLE 7.13-1: DOWNLINK CONTINUOUS THROUGHPUT ..... | 59 | +| TABLE 7.14-1: UPLINK CONTINUOUS THROUGHPUT ..... | 60 | +| TABLE 7.15-1: BIDIRECTIONAL CONTINUOUS THROUGHPUT..... | 62 | +| TABLE 7.16-1: BIDIRECTIONAL UDP DATA ON MULTIPLE FLOW..... | 64 | +| TABLE 7.17-1: SMO DISCOVERY AND O1 INTERFACE ESTABLISHMENT BETWEEN O-DU AND SMO USING STATIC CONFIGURATION IN O-DU..... | 66 | +| TABLE 7.18-1: SMO DISCOVERY AND O1 INTERFACE ESTABLISHMENT BETWEEN O-DU AND SMO..... | 68 | +| TABLE 7.19-1: CELL ACTIVATION WHEN CONFIGURATION RECEIVED FROM SMO FOR CO-LOCATED O-DU AND O-RU ..... | 70 | +| TABLE 7.20-1: CELL ACTIVATION WHEN CONFIGURATION RECEIVED FROM SMO FOR NON CO-LOCATED(REMOTE) O-RU AND O-DU ..... | 72 | +| TABLE 7.21-1: SMO IS NOTIFIED WITH THE ALARM WHEN O-DU DETECTS OUT OF SYNC FROM O-RU IN HIERARCHICAL MODEL..... | 75 | +| TABLE 7.22-1: SMO SENDS SUBSCRIPTION FOR ALARMS TO O-RU VIA O-DU AND HANDLES THE ALARM NOTIFICATION FROM O-RU VIA O-DU IN HIERARCHICAL MODEL..... | 78 | +| TABLE 7.23-1: SMO HANDLES ANY SUBSCRIBED MEASUREMENT COUNTERS RECEIVED FROM O-DU ON O1 INTERFACE.... | 79 | +| TABLE 7.24-1: O-DU SUCCESSFULLY ESTABLISH E2 INTERFACE WITH NEAR RT-RIC ..... | 81 | +| TABLE 7.25-1: NEAR RT-RIC SERVER SENDS SUBSCRIPTION REQUEST WITH IE TYPE AS REPORT TO O-DU ..... | 83 | +| TABLE 7.26-1: O-DU INCLUDES THE RIC ACTIONS NOT ADMITTED LIST IN SUBSCRIPTION RESPONSE TO NEAR RT-RIC SERVER..... | 85 | +| TABLE 7.27-1: SMO HANDLES ANY SUBSCRIBED MEASUREMENT COUNTERS RECEIVED FROM O-DU ON O1 INTERFACE.... | 87 | +| TABLE 7.28-1: MIB PERIODICITY AND SUBCARRIER SPACING ..... | 88 | +| TABLE 7.29-1: TRANSMISSION PERIODICITY CONFIGURED TO MS2P5 ..... | 91 | +| TABLE 7.30-1: MS5 TRANSMISSION PERIODICITY ..... | 93 | +| TABLE 7.31-1: 100MHZ BANDWIDTH CONFIGURATION RECEIVED FROM SMO ..... | 95 | +| TABLE 7.32-1: DL AND UL SCHEDULING INFORMATION IE'S DURING AN END-TO-END UDP FDX DATA TRANSMISSION .... | 98 | +| TABLE 7.33-1: 64 BEAMS AND 64 ANTENNA PORTS CONFIGURATION RECEIVED FROM SMO TO O-DU..... | 101 | +| TABLE 7.34-1: 8 BEAMS AND 64 ANTENNA PORTS CONFIGURATION RECEIVED FROM SMO TO O-DU..... | 104 | +| TABLE 7.35-1: O-DU IS CONFIGURED WITH 32 PUNCTURED SSB BEAMS ..... | 106 | +| TABLE 7.36-1: OCCASION AND CB-PREAMBLES PER SSB IS CONFIGURED TO 1 BY SMO..... | 109 | +| TABLE 7.37-1: CELL ACTIVATION WHEN SLICE SPECIFIC CONFIGURATION RECEIVED FROM SMO FOR O-DU ON O1 INTERFACE ..... | 112 | +| TABLE 7.38-1: SLICE REGISTRATION & PDU SESSION ESTABLISHMENT..... | 115 | +| TABLE 7.39-1: SLICE LEVEL DOWNLINK DATA PRIORITIZATION ..... | 121 | +| TABLE 7.40-1: DOWNLINK DATA SCHEDULING ON BASIS OF EQUAL SLICE PRIORITY ..... | 122 | +| TABLE 7.41-1: PERFORMANCE COUNTERS AT S-NSSAI LEVEL..... | 124 | +| TABLE 7.42-1: SLICE RECONFIGURATION ON O1 INTERFACE..... | 126 | +| TABLE 7.43-1: SLICE RECONFIGURATION ON O1 INTERFACE..... | 128 | +| TABLE 7.44-1: CELL ACTIVATION WHEN RECEIVING SYNCHRONIZATION FROM EXTERNAL TIMING SOURCE ..... | 130 | + +| | | +|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| TABLE 7.45-1: CELL ACTIVATION FAILURE WHEN FAILED TO RECEIVE SYNCHRONIZATION FROM EXTERNAL TIMING SOURCE ..... | 132 | +| TABLE 7.46-1: CELL ACTIVATION FAILURE WHEN FAIL TO RECEIVE SYNCHRONIZATION FROM EXTERNAL TIMING SOURCE AND SYNC-STATE TRANSITS FROM LOCKED TO HOLDOVER AND FREERUN ..... | 134 | +| TABLE 7.47-1: CELL ACTIVATION WHEN RECEIVING SYNCHRONIZATION FROM SECONDARY TIMING SOURCE ..... | 138 | +| TABLE 7.48-1: VERIFY O-CU AND O-DU PROVISIONS HO CONFIGURATION SENT OVER O1 INTERFACE BY SMO FOR INTER-O-DU HANDOVER WITHIN AN O-CU ..... | 141 | +| TABLE 7.49-1: VERIFY SUCCESSFUL INTRA FREQUENCY MEASUREMENT BASED INTER-O-DU HANDOVER WITHIN AN O-CU ..... | 142 | +| TABLE 7.50-1: VERIFY SUCCESSFUL INTER-O-DU HANDOVER WITHIN AN O-CU WITH MULTIPLE PDU SESSION (GBR, NON-GBR, DELAY CRITICAL GBR BEARER) AND EACH PDU SESSION HAVING SINGLE QFI ESTABLISHED ..... | 146 | +| TABLE 7.51-1: VERIFY SUCCESSFUL INTER-O-DU HANDOVER WITHIN AN O-CU WITH MULTIPLE PDU SESSION (GBR, NON-GBR, DELAY CRITICAL GBR BEARER) AND EACH PDU SESSION HAVING MULTIPLE QFI ESTABLISHED WHERE FEW PDU SESSIONS ARE ADMITTED AT TARGET DU ..... | 149 | +| TABLE 7.52-1: VERIFY SUCCESSFUL INTER FREQUENCY MEASUREMENT BASED INTER-O-DU HANDOVER WITHIN AN O-CU ..... | 152 | +| TABLE 7.53-1: VERIFY HO PREPARATION FAILURE AT TARGET O-DU DURING INTER-O-DU HANDOVER WITHIN AN O-CU ..... | 155 | +| TABLE 7.54-1: PROCEDURE TO VERIFY RRC RE-ESTABLISHMENT RECEIVED AT O-CU WHEN HO EXECUTION FAILS DURING INTER-O-DU HANDOVER WITHIN AN O-CU ..... | 158 | +| TABLE 7.55-1: BEAM FAILURE DETECTION AND RECOVERY USING SSB FOR FR2 ..... | 162 | +| TABLE 7.56-1: BEAM FAILURE DETECTION AND RECOVERY USING SSB FOR FR1 ..... | 165 | +| TABLE 7.57-1: BEAM FAILURE DETECTION AND RECOVERY USING SSB FOR FR1 WITH DRX ENABLED ..... | 168 | +| TABLE 7.58-1: BEAM FAILURE DETECTION AND RECOVERY USING CSI-RS FOR FR2 ..... | 172 | +| TABLE 7.59-1: PRIORITIZED RANDOM ACCESS DURING BEAM FAILURE RECOVERY ..... | 175 | +| TABLE 7.60-1: BEAM FAILURE DETECTION AND RECOVERY WHEN SSB/CSI-RS NOT CONFIGURED FOR DETECTION ..... | 178 | +| TABLE 7.61-1: END-TO-END DATA VERIFICATION WITH DIFFERENT CSI-RS CONFIGURATION ..... | 181 | +| TABLE 7.62-1: PROCEDURE TO VERIFY UNSUCCESSFUL CELL SETUP WHEN INVALID CSI-RS CONFIG IS USED ..... | 183 | +| TABLE 7.63-1: END-TO-END DATA VERIFICATION WITH SRS ENABLED AND UE IN MOBILITY ..... | 185 | +| TABLE 7.64-1: SUCCESSFUL COLLECTION AND TRANSFER OF MAC STATISTICS TO SMO. .... | 187 | +| TABLE 7.65-1: O-DU-OAM-AGENT SUCCESSFULLY DOWNLOADS THE CONFIGURATION FROM SMO THROUGH "FILE-DOWNLOAD REQUEST" ..... | 190 | +| TABLE 7.66-1: SUCCESSFUL COLLECTION AND TRANSFER OF L1 MEASUREMENTS ALONG WITH PARAMETER RECONFIGURATION ON E2 INTERFACE ..... | 194 | +| TABLE 7.67-1: SUCCESSFUL VO-DU AND VO-CU DEPLOYMENT ..... | 198 | +| TABLE 7.68-1: ADDITION OF VO-DU AND VO-CU INSTANCE ..... | 202 | +| TABLE 7.69-1: DELETION OF ADDITIONAL VO-DU AND VO-CU INSTANCE. .... | 205 | +| TABLE 7.70-1: SOFTWARE UPGRADE OF VO-DU. .... | 207 | +| TABLE 7.71-1: SUCCESSFUL RECONFIGURATION FOR AN VO-DU OVER O1 INTERFACE ..... | 210 | +| TABLE 7.72-1: PTP SYNC LOSS & RECOVERY IN VO-DU ..... | 212 | +| TABLE 7.73-1: SSH/ TLS VERSION COMPATIBILITY VERIFICATION DURING NETCONF SESSION CREATION AT O1 INTERFACE AND FRONTHAUL INTERFACE ..... | 215 | +| TABLE 7.74-1: VERIFICATION OF SECURED NETCONF SESSION CREATION OVER SSH OR TLS CHANNEL AT O1 INTERFACE AND FRONTHAUL INTERFACE ..... | 218 | +| TABLE 7.75-1: ACCESS CONTROL GROUP VERIFICATION FOR NETCONF SESSION ESTABLISHMENT AT O1 INTERFACE AND FRONTHAUL INTERFACE ..... | 222 | +| TABLE 7.76-1: CELL BRING UP WITH GOB CONFIGURATION ..... | 225 | +| TABLE 7.77-1: AI/ML ASSISTED NON-GOB BEAMFORMING OPTIMIZATION ON E2 INTERFACE. .... | 227 | +| TABLE 7.78-1: CELL BRING-UP IN SHARED O-RU, SINGLE OPERATOR DEPLOYMENT ..... | 231 | +| TABLE 7.79-1: SUPERVISION FAILURE OF SHARED O-RU, SINGLE OPERATOR DEPLOYMENT ..... | 234 | +| TABLE 7.80-1: PERFORMANCE MANAGEMENT OF SHARED O-RU, SINGLE OPERATOR DEPLOYMENT ..... | 237 | +| TABLE 7.81-1: BASIC RESILIENCY WITH SHARED O-RU, SINGLE OPERATOR DEPLOYMENT ..... | 240 | + +| | | +|-----------------------------------------------------------------------------------------------|-----| +| TABLE 7.82-1: SCALE-OUT OPERATION FOR O-DU WITH SHARED O-RU, SINGLE OPERATOR DEPLOYMENT ..... | 242 | +| TABLE 7.83-1: SOFTWARE UPGRADE OF O-RU ..... | 245 | +| TABLE 7.84-1: REGISTRATION & DATA TRANSFER WHEN ROHC IS ENABLED ..... | 247 | +| TABLE 7.85-1: REGISTRATION & DATA TRANSFER WHEN ROHC IS ENABLED ..... | 255 | +| TABLE 7.86-1: SLICE MEASUREMENTS ON E2 INTERFACE. .... | 261 | +| TABLE 7.87-1: SLICE RECONFIGURATION ON E2 INTERFACE. .... | 264 | +| TABLE 7.88-1: MULTI-VENDOR SLICE DEPLOYMENT ..... | 267 | +| TABLE 7.89-1: ENERGY SAVING FUNCTIONALITY WITH TRX_CONTROL FOR UNDEFINED SLEEP PERIOD..... | 270 | +| TABLE 7.90-1: ENERGY SAVING FUNCTIONALITY WITH TRX_CONTROL FOR DEFINED SLEEP PERIOD..... | 275 | + +--- + +# Foreword + +This Technical Specification (TS) has been produced by O-RAN Alliance. + +--- + +## Modal verbs terminology + +In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and "cannot" are to be interpreted as described in clause 3.2 of the O-RAN Drafting Rules (Verbal forms for the expression of provisions). + +"must" and "must not" are NOT allowed in O-RAN deliverables except when used in direct citation. + +--- + +## 1 Scope + +The contents of the present document are subject to continuing work within O-RAN and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of version date and an increase in version number as follows: + +version xx.yy.zz + +where: + +xx: the first digit-group is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initial approved document will have xx=01). Always 2 digits with leading zero if needed. + +yy: the second digit-group is incremented when editorial only changes have been incorporated in the document. Always 2 digits with leading zero if needed. + +zz: the third digit-group included only in working versions of the document indicating incremental changes during the editing process. External versions never include the third digit-group. Always 2 digits with leading zero if needed. + +This document specifies the requirements, conditions, configurations, profiles, and sequences for interoperability testing of O-RAN O-CU and O-DU deployment scenarios with other O-RAN components in standalone (SA) mode. + +This document complies with ORAN Testing and Integration Focus Group (TIFG) recommendation on a uniform documentation approach for interface testing specifications across all ORAN Working Groups (WGs). + +The following interfaces (logical or physical) are covered in IOT test cases. + +- RLC-MAC +- L1-L2 +- RRC-SDAP +- SDAP-PDCP + +- RRC-PDCP +- O1 interface +- E2 interface + +## 1.1 High Level Scenarios + +Scenarios included in Release 3 of the IOT specification are aligned with ORAN-WG8.AAD [1]. In this release, the focus is on functional behavior and limited performance of O-CU/O-DU under different traffic scenario. + +- Cell Setup and activation. +- SystemInformation (MIB, SIB1, SIB2 and SIB3). +- RACH (with PRACH Format 0). +- Registration and De-Registration procedure. +- PDU session establishment and modification. +- Idle mode Paging. +- UDP data transfer (DL/UL). +- O1 and E2 interface +- Beam Management + +The following are the performance scenarios: + +- Throughput under load condition in UL and DL. +- Static configuration files are used to configure O-CU and O-DU. + +## 1.2 Assumptions + +In current release of this test specification, the following assumptions have been made: + +- The F1 interfaces are assumed to comply with 3GPP release specifications [2], [15], [16] and [17]. +- O-CU and O-DU comply to the same version of the O-RAN Software Architecture specifications [1]. + +All elements in the interoperability test and the supporting test environment, where 3GPP support is relevant, comply to the same version of the 3GPP specification. + +## 2 References + +### 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, O-RAN cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] O-RAN.WG8.AAD.0-R004-v13.00: "Base Station O-DU and O-CU Software Architecture and APIs" +- [2] 3GPP TS 38.473: "NG-RAN; F1 Application Protocol (F1AP), (Release 15.13.0)" +- [3] 3GPP TS 38.321: "Medium Access Control (MAC) protocol specification, (Release 15.12.0)" +- [4] 3GPP TS 38.322: "Radio Link Control (RLC) protocol specification, (Release 15.5.0)" +- [5] 3GPP TS 38.323: "Packet Data Convergence Protocol (PDCP) specification, (Release 15.7.0)" +- [6] 3GPP TS 37.324 "Service Data Adaptation Protocol (SDAP), (Release 15.1.0)" +- [7] 3GPP TS 38.300: "NR; NR and NG-RAN Overall Description, (Release 15.12.0)" +- [8] 3GPP TS 38.331: "Radio Resource Control (RRC) protocol specification, (Release 15.13.0)" +- [9] 3GPP TS 38.300: "NR; NR and NG-RAN Overall Description, (Release 15.12.0)" +- [10] 3GPP TS 38.425: "NR user plane protocol, (Release 15.7.0)" +- [11] 3GPP TS 37.214: "Physical layer procedures for data, (Release 15.3.0)" +- [12] 222.10.01: "5G FAPI: PHY API Specification" +- [13] 3GPP TR 21.905: "Vocabulary for 3GPP Specifications, (Release 17.0.0)" +- [14] 3GPP TR 38.104: "NR; Base Station (BS) radio transmission and reception, (Release 15.13.0)" +- [15] 3GPP TS 38.470: "NG-RAN; F1 general aspects and principles, (Release 15.7.0)" +- [16] 3GPP TS 38.472: "NG-RAN; F1 signaling transport, (Release 15.7.0)". +- [17] 3GPP TS 38.474: "NG-RAN; F1 data transport, (Release 15.3.0)". +- [18] 3GPP TS 38.211: "NR; Physical channels and modulation, (Release 15.8.0)". +- [19] O-RAN.WG5.C.1-v11.00: "NR C-plane profile" +- [20] 3GPP TS 38.413: "NG-RAN; NG Application Protocol (NGAP), (Release 15.11.0)" +- [21] 3GPP TS 24.501: "Non-Access-Stratum (NAS) protocol for 5G System (5GS); Stage 3, (Release 16.8.0)" +- [22] O-RAN.WG5.O-DU-O1.0-R003-v08.00 : "O1 Interface specification for O-DU" +- [23] RFC-3736: "Stateless Dynamic Host Configuration Protocol (DHCP) Service for IPv6" + +- [24] O-RAN.WG4.MP.0-R003-v13.00: “Management Plane Specification” +- [25] 3GPP TS 28.552: “Management and orchestration; 5G performance measurements, (Release 16.10.0)” +- [26] O-RAN.WG4.CUS.0-R003-v13.00: Control, User and Synchronization Plane Specification +- [27] O-RAN.WG5.O-DU-O1.0-R003-v07.00-YANGs: “O1 Interface for O-DU 7.0 - YANG Models” +- [28] O-RAN.WG10.O1-Interface.0-R003-v11.00 Technical Specification, “O-RAN Operations and Maintenance Interface Specification” +- [29] O-RAN.WG1.Use-Cases-Analysis-Report-R003-v12.00, “O-RAN Working Group 1 Use Cases Analysis Report” +- [30] TS 38.133: “Requirements for support of radio resource management, (Release 17.5.0)” +- [31] O-RAN.WG6.CADS-v05.00 Technical Report, “Cloud Architecture and Deployment Scenarios for O-RAN Virtualized RAN” +- [32] O-RAN.WG6.ORCH-USE-CASES-R003-v08.00 Technical Specification, “Cloudification and Orchestration Use Cases and Requirements for O-RAN Virtualized RAN” +- [33] O-RAN.WG6.O-Cloud Notification API-v03.00 Technical Specification, “O-Cloud Notification for Event Consumers” +- [34] O-RAN.WG11.Security-Protocols-Specification.O-R003-v07.00, “Security Protocols Specifications” +- [35] O-RAN.WG3.UCR-R003-v04.00, “O-RAN Working Group 3 Near-Real-time RAN Intelligent Controller Use Cases and Requirements” +- [36] O-RAN.WG3.E2SM-KPM-R003-v04.00, “Near-Real-time RAN Intelligent Controller E2 Service Model (E2SM) KPM” +- [37] O-RAN.WG3.E2SM-RC-R003-v04.00, “Near-Real-time RAN Intelligent Controller E2 Service Model (E2SM), RAN Control” +- [38] O-RAN.WG1.Use-Cases-Detailed-Specification-R003-v13.00, “Use Cases Detailed Specification” + +## 3 Definition of terms, symbols and abbreviations + +### 3.1 Terms + +For the purposes of the present document, the following terms apply: + +**O-CU:** O-RAN Central Unit is a logical node hosting PDCP, RRC, SDAP, and other control functions. + +**O-DU:** O-RAN Distributed Unit is a logical node hosting RLC, MAC, and High-PHY layers based on a lower layer functional split. + +**O-RU:** O-RAN Radio Unit is a logical node hosting Low-PHY layer and RF processing based on a lower layer functional split. + +**F1 interface:** The interface defined by 3GPP TS [15], 3GPP TS [16], and 3GPP TS [2], to be further interpreted as per O-RAN WG5 specification for interoperability between O-CU and O-DU from different vendors. + +### 3.2 Symbols + +For the purposes of the present document, the following symbols apply: + +### 3.3 Abbreviations + +For the purposes of the present document, the [following] abbreviations [given in ... and the following] apply: + +| | | +|------|-------------------------------------------| +| 3GPP | Third Generation Partnership Project | +| 5G | Fifth-Generation Mobile Communications | +| AMC | Adaptive Modulation and Coding | +| BWP | Bandwidth Part | +| CA | Certificate Authority | +| CSI | Channel State Information | +| CU | Centralized Unit as defined by 3GPP | +| DCI | Downlink Control Information | +| DHCP | Dynamic Host Configuration Protocol | +| DL | Downlink | +| DU | Distributed Unit as defined by 3GPP | +| DUT | Device Under Test | +| E1AP | E1 Application Protocol | +| F1AP | F1 Application Protocol | +| FAPI | Functional Application Platform Interface | +| FDD | Frequency Division Duplex | + +| | | +|---------|-------------------------------------------------------| +| HARQ | Hybrid Automatic Repeat Request | +| LLS | Lower Layer Split | +| MAC | Medium Access Control protocol | +| MIMO | Multiple Input Multiple Output | +| MT | Mobile-Termination | +| MU-MIMO | Multiple User MIMO | +| NETCONF | Network Configuration Protocol | +| NG-RAN | Next Generation Radio Access Network | +| NR | New Radio | +| O-CU | O-RAN Centralized Unit as defined by O-RAN | +| O-DU | O-RAN Distributed Unit as defined by O-RAN | +| OFH | Open Front Haul protocol defined by O-RAN | +| OFH-C | OFH Control plane | +| OFH-U | OFH User plane | +| O-RU | O-RAN Radio Unit as defined by O-RAN | +| PBCH | Physical Broadcast Channel | +| PDCCH | Physical Downlink Control Channel | +| PHY | Physical (L1) access layer of RAN | +| PRACH | Physical Random Access Channel | +| PUCCH | Physical Uplink Control Channel | +| QAM | Quadrature Amplitude Modulation | +| QoS | Quality of Service | +| QPSK | Quadrature (Quaternary) Phase Shift Keying | +| RA | Registration Authority | +| RAN | Radio Access Network | +| Rel-x | Release number: where, x is the actual release number | +| RF | Radio Frequency | +| RIC | RAN Intelligence Controller | +| RLC | Radio Link Control protocol | +| RRC | Radio Resource Control protocol | +| RT | Real Time | +| RU | Radio Unit | +| Rx | Receiver | +| SCS | Sub-Carrier Spacing | +| SDAP | Service Data Adaptation Protocol | +| SDU | Service Data Unit | + +| | | +|---------|----------------------------------| +| SLA | Slice Level Agreement | +| SMO | Service Management Orchestration | +| SRS | Sounding Reference Signal | +| SU-MIMO | Singer User MIMO | +| TDD | Time Division Duplex | +| TLS | Transport Layer Security | +| TS | Technical Specification | +| TTI | Transmission Time Interval | +| Tx | Transmitter | +| UE | User Equipment | +| UL | Uplink | +| WG | Working Group | + +--- + +## 4 General Test Conditions and Declarations + +In this document, scenarios are considered with real HW (see 7.17), as well as in a simulated environment. Parameters are defined for configurations based on ORAN-WG8.AAD [1], the 3GPP document, and validation are done around these parameters. These validations are done on all relevant nodes through internal/specific logs. + +--- + +## 5 Exclusions and Open Points + +This document excludes the following interfaces (if applicable): + +- E1 + +## 6 Test Summary + +### 6.1 Test Case Summary + +Test cases covered in this document are derived from O-RAN.WG8.AAD [1]. + +**Table 6.1-1: Test Summary** + +| Module Name | Test Case | Covered in Release | Reference | +|-------------|-----------------------------------------------------------------------------------------------------------|--------------------|-------------------------------------------------------------| +| O-CU, O-DU | Cell setup | Release 1 | O-RAN.WG5.C.1 [19],<br>3GPP TS [2],<br><br>ORAN-WG8.AAD [1] | +| O-CU, O-DU | SystemInformation: MIB | Release 1 | 3GPP TS [2],<br><br>ORAN-WG8.AAD [1] | +| O-CU, O-DU | SystemInformation: SIB1 | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | SystemInformation: SIB2 | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | SystemInformation: SIB3 | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Random Access Procedure | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Registration Procedure | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | UE Initiated De-Registration | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | PDU Establishment Procedure | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | PDU Session Modification | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Idle mode Paging | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Downlink Continuous Throughput | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Uplink Continuous Throughput | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Bidirectional Continuous Throughput | Release 1 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Bidirectional throughput on multiple flow | Release 1 | ORAN-WG8.AAD [1] | +| O1 | SMO Discovery and O1 Interface establishment between O-DU and SMO using static configuration on the O-DU. | Release 2 | ORAN-WG8.AAD [1] | +| O1 | SMO Discovery and O1 Interface establishment between O-DU and SMO. | Release 2 | ORAN-WG8.AAD [1] | +| O1 | Verify the cell activation successful when configuration received from SMO for co-located O-DU and O-RU. | Release 2 | ORAN-WG8.AAD [1] | +| O1 | Verify the cell activation successful when configuration received from | Release 2 | ORAN-WG8.AAD [1] | + +| | | | | +|----|----------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------|------------------| +| | SMO for non co-located(remote) O-RU and O-DU. | | | +| O1 | Verify SMO is notified with the alarm when O-DU detects out of sync from O-RU in hierarchical model. | Release 2 | ORAN-WG8.AAD [1] | +| O1 | Verify SMO sends subscription to O-RU via O-DU for alarms and handles the alarm notification from O-RU via O-DU. | Release 2 | ORAN-WG8.AAD [1] | +| O1 | Verify SMO handles any subscribed measurement counters received from O-DU on O1 interface. | Release 2 | ORAN-WG8.AAD [1] | +| E2 | Verify O-DU successfully establish E2 Interface with near RT-RIC. | Release 2 | ORAN-WG8.AAD [1] | +| E2 | Verify near RT-RIC server sends subscription request with type as REPORT to O-DU. | Release 2 | ORAN-WG8.AAD [1] | +| E2 | Verify O-DU includes the RIC Actions Not Admitted List in subscription response to near RT-RIC server. | Release 2 | ORAN-WG8.AAD [1] | +| E2 | Verify O-DU sends periodic report to the subscribed features to near RT-RIC server. | Release 2 | ORAN-WG8.AAD [1] | +| O1 | Verify UE attach is successful with the given SSB periodicity and sub-carrier spacing as part of cell configuration structure from SMO to O-DU for FR1 configuration | Release 3 | ORAN-WG8.AAD [1] | +| O1 | Verify UE attach is successful with Transmission periodicity configured to ms2p5 for FR1 configuration | Release 3 | ORAN-WG8.AAD [1] | +| O1 | Verify UE attach is successful with Transmission periodicity configured to ms5 for FR1 configuration | Release 3 | ORAN-WG8.AAD [1] | +| O1 | Verify cell bring up is successful with 100Mhz bandwidth configuration received from SMO for FR1 configuration | Release 3 | ORAN-WG8.AAD [1] | +| O1 | Verify DL and UL scheduling information IE's during an end-to-end UDP FDX data transmission for FR1 configuration | Release 3 | ORAN-WG8.AAD [1] | +| O1 | Verify cell bring up is successful with 64 beams and 64 antenna ports configuration received from SMO to O-DU for FR2 configuration | Release 3 | ORAN-WG8.AAD [1] | +| O1 | Verify cell bring up is successful with 8 beams and 64 antenna ports configuration received from | Release 3 | ORAN-WG8.AAD [1] | + +| | | | | +|------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------|------------------| +| | SMO to O-DU for FR1 configuration | | | +| O1 | Verify cell bring up is successful and UE attach when the O-DU is configured with 32 punctured SSB beams for FR2 configuration | Release 3 | ORAN-WG8.AAD [1] | +| O1 | Verify cell bring up is successful when the parameter Occasion And CB-Preambles per SSB is configured to 1 by SMO for FR1 configuration | Release 3 | ORAN-WG8.AAD [1] | +| O1 | Verify the successful cell activation when slice specific configuration containing list of slices in the TA per PLMN is sent towards MAC/SCH on the O1 interface. | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify UE Registration and PDU session establishment procedure with an allowed S-NSSAI. | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify downlink data prioritization/scheduling on basis of slice differentiation in-case of each UE with single PDU session per slice. | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | verify downlink data scheduling on basis of QoS flow prioritization when two PDU sessions have equal slice priority. | Release 4 | ORAN-WG8.AAD [1] | +| O1 | Verify key performance metrics with the sub-counters at S-NSSAI level. | Release 4 | ORAN-WG8.AAD [1] | +| O1 | Verify successful slice re-configuration when RRM Policy is updated on the O1 interface. | Release 4 | ORAN-WG8.AAD [1] | +| O1 | Verify slice reconfiguration failure in-case of incorrect S-NSSAI is updated on the O1 interface. | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify cell activation when O-DU is receiving synchronization from external timing source and sync-state is locked. | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify cell activation when O-DU is receiving synchronization from external timing source and sync-state is not locked. | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify cell activation when O-DU is receiving synchronization from external timing source and sync-state transits from locked to holdover and freerun. | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify cell activation when O-DU successfully receive synchronization from secondary source when sync fails with the primary source. | Release 4 | ORAN-WG8.AAD [1] | + +| | | | | +|------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------|------------------| +| O-CU, O-DU | Verify O-CU and O-DU provisions HO configuration sent over O1 interface by SMO during inter-O-DU handover within an O-CU | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify successful intra frequency measurement based inter-O-DU handover within an O-CU | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having single QFI established | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having multiple QFI established where few PDU sessions are admitted at target DU | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify successful inter frequency measurement based inter-O-DU handover within an O-CU | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify HO preparation failure at target O-DU during inter-O-DU handover within an O-CU | Release 4 | ORAN-WG8.AAD [1] | +| O-CU, O-DU | Verify RRC Re-establishment received at O-CU when HO execution fails during inter-O-DU handover within an O-CU | Release 4 | ORAN-WG8.AAD [1] | +| O-DU | Verify beam failure detection and recovery using SSB for detection as well as recovery with DRX disabled and 64 beams for FR2 configuration. | Release 5 | ORAN-WG8.AAD [1] | +| O-DU | Verify beam failure detection and recovery using SSB for detection as well as recovery with DRX disabled and 8 beams for FR1 configuration. | Release 5 | ORAN-WG8.AAD [1] | +| O-DU | Verify beam failure detection and recovery using SSB for detection as well as recovery with DRX enabled and 8 beams for FR1 configuration. | Release 5 | ORAN-WG8.AAD [1] | +| O-DU | Verify beam failure detection and recovery using CSI-RS for detection as well as recovery with DRX disabled and 32 beams for FR2 configuration. | Release 5 | ORAN-WG8.AAD [1] | +| O-DU | Verify prioritized random access during beam failure recovery. | Release 5 | ORAN-WG8.AAD [1] | +| O-DU | Verify beam failure detection and recovery when SSB/CSI-RS not | Release 5 | ORAN-WG8.AAD [1] | + +| | | | | +|----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------|------------------| +| | configured under radioLinkMonitoringConfig. | | | +| O-DU | Verify end-to-end data with different CSI-RS configuration. | Release 5 | ORAN-WG8.AAD [1] | +| O-DU | Verify cell is not up with invalid CSI-RS configuration. | Release 5 | ORAN-WG8.AAD [1] | +| O-DU | Verify end-to-end data when SRS is enabled and UE is moving. | Release 5 | ORAN-WG8.AAD [1] | +| O1 | Verify successful collection and transfer of MAC statistics for MU-MIMO from O-DU-OAM-Agent to SMO. | Release 5 | ORAN-WG8.AAD [1] | +| O1 | Verify O-DU-OAM-Agent successfully download the configuration from SMO for beamforming optimization through "file-download request". | Release 5 | ORAN-WG8.AAD [1] | +| E2 | Verify successful collection and transfer of L1 measurements along with parameter reconfiguration for AI/ML assisted Beam Selection Optimization on E2 interface. | Release 5 | ORAN-WG8.AAD [1] | +| O-Cloud | Verify successful vO-DU and vO-CU deployment on an O-Cloud. | Release 7 | ORAN-WG8.AAD [1] | +| O-Cloud | Verify successful addition of vO-DU and vO-CU instance when network demand increases beyond current NF capacity threshold. | Release 7 | ORAN-WG8.AAD [1] | +| O-Cloud | Verify successful deletion of vO-DU and vO-CU instance when network demand reduces below NF capacity threshold. | Release 7 | ORAN-WG8.AAD [1] | +| O-Cloud | Verify successful software upgrade for vO-DU. | Release 7 | ORAN-WG8.AAD [1] | +| O-Cloud | Verify successful reconfiguration for vO-DU. | Release 7 | ORAN-WG8.AAD [1] | +| O-Cloud | Verify vO-DU functionality during PTP sync loss and recovery. | Release 7 | ORAN-WG8.AAD [1] | +| Security | Verification of SSH/ TLS version compatibility of secured NETCONF session creation at O1 interface and fronthaul interface. | Release 7 | ORAN-WG8.AAD [1] | +| Security | Verification of successful secured NETCONF session creation over SSH/ TLS channel at the O1 interface and fronthaul interface. | Release 7 | ORAN-WG8.AAD [1] | +| Security | Verification of Access Control Groups defined for NETCONF sessions created at O1 interface and fronthaul interface. | Release 7 | ORAN-WG8.AAD [1] | + +| | | | | +|-----------------------|---------------------------------------------------------------------------------------------------------------------------------|------------|------------------| +| O1 | Verify cell bring up using GoB configuration received from SMO is successful. | Release 8 | ORAN-WG8.AAD [1] | +| E2 | Verify successful AI/ML-assisted non-GoB beamforming optimization in Near RT RIC. | Release 8 | ORAN-WG8.AAD [1] | +| O-RU | Verify successful cell bring-up of Shared O-RU in Single operator deployment. | Release 10 | ORAN-WG8.AAD [1] | +| O-RU | Verify successful detection for supervision failure of Shared O-RU in Single operator deployment. | Release 10 | ORAN-WG8.AAD [1] | +| O-RU | Verify successful performance management of a Shared O-RU in Single operator deployment. | Release 10 | ORAN-WG8.AAD [1] | +| O-RU | Verify successful switchover from active to standby O-DU node in Single operator deployment. | Release 10 | ORAN-WG8.AAD [1] | +| O-RU | Verify successful scale-out operation for a O-DU node by the SMO in Single operator deployment. | Release 10 | ORAN-WG8.AAD [1] | +| O-RU | Verify successful software upgrade for O-RU triggered by O-DU. | Release 10 | ORAN-WG8.AAD [1] | +| RoHC | Verify successful configuration and data header compression/de-compression when RoHC profile "0x0001" is used for "RTP/UDP/IP". | Release 11 | ORAN-WG8.AAD [1] | +| RoHC | Verify successful configuration and data header compression/de-compression when RoHC profile "0x0002" is used for "UDP/IP". | Release 11 | ORAN-WG8.AAD [1] | +| RAN Slicing | Verify successful collection and transfer of slice performance reports via E2 interface. | Release 11 | ORAN-WG8.AAD [1] | +| RAN Slicing | Verify successful policy delivery and execution for slice reconfiguration via E2 interface. | Release 11 | ORAN-WG8.AAD [1] | +| RAN Slicing | Verify successful UE registration and data transmission in a Shared O-RU multi-vendor slice deployment. | Release 11 | ORAN-WG8.AAD [1] | +| Network energy Saving | Verify network energy saving functionality in TRX_CONTROL mode configured with undefined Sleep Period | Release 12 | ORAN-WG8.AAD [1] | +| Network energy Saving | Verify network energy saving functionality in TRX_CONTROL mode configured with defined Sleep Period | Release 12 | ORAN-WG8.AAD [1] | + +The IOT profiles are included in Annex B. Additional profiles are added in the future releases of WG8 Stack Interoperability Test Specification. + +## 7 Interoperability (IOT) Standard Test Definitions + +### 7.1 Interoperability Standard Test Definitions + +#### 7.1.1 Standard Test Configurations + +Interoperability testing is performed to validate whether the software of O-CU can interact with the software and system components of O-DU. The message flow and IEs are compliant to 3GPP and O-RAN Software Architecture [1]. The focus of this document is to validate interoperability of O-CU and O-DU of same/different vendors. + +#### 7.1.2 DUT + +O-DU and O-CU are the physical components considered as DUTs. Other network elements, such as O-RU, may be real hardware or simulated based on the test requirements. In certain test cases, the O-DU or O-CU may be simulated. + +For details on the test setup and configuration, see 7.17. + +![Figure 7.1.2-A: DUT configuration diagram showing the architecture of O-CU(DUT) and O-DU(DUT) components, their interfaces, and connections to Core Sim and NR-UE-SIM.](084f4a9c4e78cb2802c66fd20ce682b3_img.jpg) + +``` + +graph TD + subgraph O_CU_DUT [O-CU(DUT)] + UPlane[U-Plane] + CPlane[C-Plane] + SDAP[SDAP] + RRC[RRC] + PDCP[PDCP] + UPlane <--> SDAP + CPlane <--> RRC + SDAP <--> PDCP + RRC <--> PDCP + end + + subgraph O_DU_DUT [O-DU(DUT)] + RLC[RLC] + MAC[MAC] + HIGHPHY[HIGH PHY] + RLC <--> MAC + MAC <--> HIGHPHY + end + + O_CU_DUT <-->|F1-U| O_DU_DUT + O_CU_DUT <-->|F1-C| O_DU_DUT + + CoreSim[Core Sim] --> CPlane + NRUESIM[NR-UE-SIM(L3, MAC, RLC, PDCP)] <--> MAC + +``` + +The diagram illustrates the DUT configuration. It shows two main functional blocks: O-CU(DUT) and O-DU(DUT). O-CU(DUT) contains U-Plane, C-Plane, SDAP, RRC, and PDCP layers. O-DU(DUT) contains RLC, MAC, and HIGH PHY layers. The O-CU(DUT) block is connected to the O-DU(DUT) block via F1-U and F1-C interfaces. The O-CU(DUT) block is also connected to the Core Sim block via the C-Plane. The O-DU(DUT) block is connected to the NR-UE-SIM(L3, MAC, RLC, PDCP) block via the MAC layer. + +Figure 7.1.2-A: DUT configuration diagram showing the architecture of O-CU(DUT) and O-DU(DUT) components, their interfaces, and connections to Core Sim and NR-UE-SIM. + +**Figure 7.1.2-A: DUT configuration** + +#### 7.1.3 Testing Tools + +In all test cases, O-RU may be real or simulated. In certain test cases, the O-DU or O-CU may be simulated. + +- **O-CU or O-CU Emulator:** A separate O-CU or simulated O-CU is used based on the test setup. More details are mentioned in 7.17. +- **O-DU or O-DU Emulator:** A separate O-DU or simulated O-DU is used based on the test setup. More details are mentioned in 7.17. + +- **O-RU or O-RU Emulator:** A separate O-RU or simulated O-RU is used based on the test requirement. More details are mentioned in 7.17. +- **Test UE or UE Emulator:** An End-to-end (E2E) test requires a UE. It can be a real UE or simulated one based on the test requirement. More details are mentioned in 7.17. +- **Core or Core Emulator:** An E2E test requires a core network. A real Core Network (CN) or simulated core is used in E2E setup. + +## 7.1.4 Time Synchronization + +The O-DU and O-RU components are required to be synchronized to a common system time and master time source unless otherwise stated. + +## 7.2 ORAN.WG8.IOT.001: Cell Setup + +### 7.2.1 Test Purpose + +The purpose of this test case is to explain the cell setup when O-DU and O-CU started separately. + +### 7.2.2 Reference Requirements + +For detailed requirements, refer to the section 9.2 and 10.1.3 in ORAN-WG8.AAD [1]. + +### 7.2.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- NETCONF client is operational. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- Use the default O-DU configuration files to configure O-DU. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-DU and O-RU to time synchronize using one of the O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-CU and O-DU may be configured with YANG data model or static configuration files. + +### 7.2.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. + +- **Testing tools:** are required for this test scenario: +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A.1. +- Test profile 2, refer Annex B Test profile section B.2.1. + +## 7.2.5 Test Procedure + +The following table describes the test procedures for cell setup. + +**Table 7.2-1: Cell Setup** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends Cell Configuration to O-DU. | <b>O-DU ← SMO</b> | <p>Verify SMO sends all the mandatory IEs to O-DU as per the data formats supported in Section 12.2 of [22].</p> <p>Verify the IEs are carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC.</p> <p>Verify MAC sends Cell Configuration Request to SCH when it receives configuration to create a new cell as per Section 11.2.4.2.1 of [1].</p> | +| 2 | O-DU sends cell configurations to O-RU. | <b>O-RU ← O-DU</b> | <p>Verify O_DU sends carrier configuration updates to O-RU using M-plane edit-config model as described from section 9.1.5 of [24].</p> <p>Verify the state of the O-RU is changed to INACTIVE.</p> | +| 3 | O-DU receives configuration update response from O-RU. | <b>O-RU → O-DU</b> | <p>Verify RU applies new carrier configuration and sends carrier state change notification to O-DU set as READY.</p> <p>Verify the state of O-RU is changed to ACTIVE.</p> <p>O-RU sends carrier state change notification as per M-plane model described from section 15.3 of [24].</p> | + +| | | | | +|----|-------------------------------------------------------------------------------------|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 4 | O-DU retrieves synchronization status from O-RU to confirm it is time synchronized. | <b>O-RU ← O-DU</b> | <p>Verify O-DU receives synchronization status from O-RU using the sync-state M-plane model as described from section 13.1 of [24].</p> <p>If sync-state value is set to FREERUN, O-DU updates the timing architecture to O-RU and retrieves the synchronization status again and expects the O-RU sync-state gets changed to LOCKED.</p> <p>If sync-state is set to LOCKED, O-DU ensures that O-RU is time synchronized and proceeds with the cell setup.</p> | +| 5 | O-DU sends sync-state information and set the operational state in SMO. | <b>O-DU → SMO</b> | <p>Verify SCH sends Cell Configuration Response to MAC as per Section 11.2.4.3.1 of [1]</p> <p>Verify O-DU sends the sync-state as LOCKED to SMO. Verify O-DU set the operational state to ENABLED state.</p> | +| 6 | SMO sets the administrate state of O-DU. | <b>O-DU ← SMO</b> | Verify O-DU sets the administrative state to UNLOCKED state. | +| 7 | O-DU sends an F1 SETUP REQUEST to establish connectivity between the O-DU and O-CU. | <b>O-DU → O-CU</b> | Verify O-DU sends F1 SETUP REQUEST message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-CU-CP. (Control Unit). | +| 8 | O-CU sends NGAP Setup Request to AMF. | <b>O-CU → AMF</b> | Verify the NGAP Setup Request contains all the mandatory IEs mentioned in the section 9.2.6.1 of 3GPP Specification [20]. | +| 9 | O-CU receives NGAP Setup Response from AMF. | <b>O-CU ← AMF</b> | Verify AMF sends NGAP Setup Response message containing all the mandatory IEs mentioned in 9.2.6.1 of 3GPP Specification [20]. | +| 10 | O-DU receives F1 SETUP RESPONSE from O-CU. | <b>O-DU ← O-CU</b> | Verify O-CU sends F1 SETUP RESPONSE message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-DU. | +| 11 | Cell Bring-up is initiated at O-CU | <b>O-DU ← O-CU</b> | <p>O-CU sends the F1AP gNB-CU configuration update to O-DU.</p> <p>F1AP gNB-CU configuration update message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>O-DU adds the cell information according to IE Served-Cells-To-Add-List.</p> | +| 12 | O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU. | <b>O-DU → O-CU</b> | <p>Verify O-DU sends the gNB-CU CONFIGURATION UPDATEACKNOWLEDGE message to O-CU.</p> <p>F1AP gNB-CU configuration update Ack message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> | + +| | | | | +|----|-------------------------------------------------------------------------|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 13 | Activate the cell from the O-DU | <b>O-DU → O-CU</b> | <p>O-DU sends the F1AP gNB-DU configuration update to O-CU.</p> <p>F1AP gNB-DU configuration update message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>O-DU should activate the cell information according to the service-state IE.</p> | +| 14 | O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU. | <b>O-DU ← O-CU</b> | <p>Verify O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU.</p> <p>F1AP gNB-DU configuration update Ack message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 15 | Verify the status of the cell. | <b>O-DU/O-CU</b> | <p>Verify O-DU sends cell status as ACTIVE to O-RU.</p> <p>Verify SMO shows O-CU and O-DU operational and newly added cell is up and RF state of O-RU is active.</p> | + +## 7.3 ORAN.WG8.IOT.002: SystemInformation-MIB + +### 7.3.1 Test Purpose + +The purpose of this test case is to verify broadcast of MIB. + +### 7.3.2 Reference Requirements + +For detailed requirements, refer to the section 10.1.3 in ORAN-WG8.AAD [1]. + +### 7.3.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- NETCONF client is operational. +- F1AP is established. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-DU and O-RU to time synchronize using one of the O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- Use default SSB configuration defined in O-DU configuration files. + +## 7.3.4 Test Setup and Configuration + +- **DUTs:** Single O-DU and Single O-CU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A.1. + - For details on the MIB and SSB test profiles, refer B.2.1. + +## 7.3.5 Test Procedure + +The following table describes the test procedures for SystemInformation-MIB. + +**Table 7.3-1: SystemInformation-MIB** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------------------------------|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1. | SMO sends Cell Configuration to O-DU. | <b>O-DU ← SMO</b> | Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC: <ul style="list-style-type: none"> <li>• Carrier Configuration</li> <li>• Cell Configuration</li> <li>• SSB Configuration</li> </ul> | +| 2. | Cell bring-up. | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>Verify O-DU sends carrier configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.<br><br>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify O-DU sets the administrative state to UNLOCKED state. | +| 3 | The UE is switched on. | - | Verify SCH provides the Downlink Broadcast allocation for SSB for a TTI scheduling PBCH with following IEs. <ul style="list-style-type: none"> <li>• SSB Index</li> <li>• SSB Information</li> <li>• ssbSubcarrierOffset</li> </ul> Verify O-DU transmits the SS Block and MIB contains: systemFrameNumber, subCarrierSpacingCommon, ssb-SubcarrierOffset, dmrs-TypeA-Position and pdccch-ConfigSIB1. | + +| | | | | +|---|---------------------------------------------------------|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------| +| 4 | O-DU sends SSB configuration as per define periodicity. | <b>UE ← O-DU/<br/>O-CU</b> | Verify UE log (Test Tool) that O-DU broadcast SS burst blocks in every configured SSB periodicity in a first half frame within SFN. | +| 5 | UE receive BCCH-BCH-Message MIB from O-DU. | <b>UE ← O-DU/<br/>O-CU</b> | Verify Does UE receive BCCH-BCH-Message MIB from O-DU and MIB contain IEs as per the section 6.2.2 of 3GPP Specification [8]. Verify this on Test Tool. | + +## 7.4 ORAN.WG8.IOT.003: Systeminformation-SIB1 + +### 7.4.1 Test Purpose + +The purpose of this test case is to verify broadcast of SIB1. + +### 7.4.2 Reference Requirements + +For detailed requirements, refer to the section 10.1.3 in ORAN-WG8.AAD [1]. + +### 7.4.3 Initial Condition + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- NETCONF client is operational. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- O-DU and O-RU to time synchronize using one of the O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.4.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario: +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A.1. + +- For details on the MIB and SSB test profiles, refer B.2.1. + +## 7.4.5 Test Procedure + +The following table describes the test procedures for SystemInformation-SIB1. + +**Table 7.4-1: SystemInformation-SIB1** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1. | SMO sends Cell Configuration to O-DU. | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <ul style="list-style-type: none"> <li>Carrier Configuration</li> <li>Cell Configuration</li> <li>SSB Configuration</li> <li>CSI-RS Configuration</li> <li>PRACH Configuration</li> <li>TDD Configuration</li> </ul> | +| 2. | Cell bring-up. | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>Verify O-DU sends carrier configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24]].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 3. | O-DU send SIB1. | <b>UE ← O-DU/O-CU</b> | <p>Verify Downlink Broadcast Allocation with following IEs sent by SCH to MAC:</p> <ul style="list-style-type: none"> <li>DL DCIDL SCH</li> <li>System Information Indicator</li> <li>SI Content</li> </ul> <p>Verify DL Scheduling Information with following IEs sent by SCH to MAC:</p> <ul style="list-style-type: none"> <li>System Information Indicator</li> <li>SI Content</li> <li>SIB1 Transmission Mode</li> </ul> <p>Verify subCarrierSpacingCommon for SIB1 subcarrier spacing and ssb-subcarrierOffset, which indicate SIB1, are present or not.</p> <p>The UE received SIB1 with configured periodicity and SIB 1 contains IE as per 3GPP Specification [8].</p> | + +## 7.5 ORAN.WG8.IOT.004: SystemInformation-SIB2 + +### 7.5.1 Test Purpose + +The purpose of this test case is to verify broadcast of SIB2 by O-DU. + +### 7.5.2 Reference Requirements + +For detailed requirements, refer to the section 10.1.3 in ORAN-WG8.AAD [1]. + +### 7.5.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- O-CU sends SIB2, SIB3 in F1 Setup Response and F1 setup is successful. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- Broadcast of MIB and SIB1 is successful. + +### 7.5.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A.1. + - For details on the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profile, see B.3. + +### 7.5.5 Test Procedure + +The following table describes the test procedures for SystemInformation-SIB2. + +**Table 7.5-1: SystemInformation-SIB2** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|----|---------------------------------------|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1. | O-DU send SIB2. | UE ← O-DU/<br>O-CU | <p>Verify Downlink Broadcast Allocation with following IEs sent by SCH to MAC:</p> <ul style="list-style-type: none"> <li>DL DCIDL SCH</li> <li>System Information Indicator</li> <li>SI Content</li> </ul> <p>Verify DL Scheduling Information with following IEs sent by SCH to MAC:</p> <ul style="list-style-type: none"> <li>System Information Indicator</li> <li>SI Content</li> </ul> | +| 2. | UE receives SIB2 broadcast from O-DU. | UE ← O-DU/<br>O-CU | <p>Verify that O-DU broadcasts SIB2 to UE as per the scheduling information decoded from SIB1.</p> <p>Verify all the mandatory IEs as per section 6.3.1 in 3GPP Specification [8].</p> | + +## 7.6 ORAN.WG8.IOT.005: Systeminformation-SIB3 + +### 7.6.1 Test Purpose + +The purpose of this test case is to verify broadcast of SIB3 by O-DU. + +### 7.6.2 Reference Requirements + +For detailed requirements, refer to the section 10.1.3 in ORAN-WG8.AAD [1]. + +### 7.6.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- O-CU sends SIB2, SIB3 in F1 Setup Response and F1 setup is successful. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- Broadcast of MIB and SIB1 is successful. + +### 7.6.4 Test Setup and Configuration + +- DUTs:** single O-DU and single O-CU. +- Testing tools:** are required for this test scenario: +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + +- For details on the test setup refer Annex A.1. +- For details on the MIB and SSB test profile, see B.2.1. +- For details on the SIB1 test profile, see B.3. + +## 7.6.5 Test Procedure + +The following table describes the test procedures for SystemInformation-SIB3. + +**Table 7.6-1: SystemInformation-SIB3** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------------------------------|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1. | O-DU send SIB3. | UE ← O-DU/<br>O-CU | <p>Verify Downlink Broadcast Allocation with following IEs sent by SCH to MAC:</p> <ul style="list-style-type: none"> <li>• DL DCIDL SCH</li> <li>• System Information Indicator</li> <li>• SI Content</li> </ul> <p>Verify DL Scheduling Information with following IEs sent by SCH to MAC:</p> <ul style="list-style-type: none"> <li>• System Information Indicator</li> <li>• SI Content</li> </ul> | +| 2. | UE receives SIB3 broadcast from O-DU. | UE ← O-DU/<br>O-CU | <p>Verify that O-DU broadcasts SIB3 to UE as per the scheduling info decoded from SIB1.</p> <p>Verify all the mandatory IEs as per section 6.3.1 in 3GPP Specification [8].</p> | + +## 7.7 ORAN.WG8.IOT.006: Random Access Procedure + +### 7.7.1 Test Purpose + +The purpose of this test case is to verify using long/short preamble UE attach procedure. This case describes PRACH transmission after getting the parameter in SIB1. + +### 7.7.2 Reference Requirements + +For detailed requirements, refer to the section Annex A – RACH procedure in ORAN-WG8.AAD [1]. + +### 7.7.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- NETCONF client is operational. +- F1AP is established. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. + +- O-DU and O-RU to time synchronize using one of the O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.7.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A.1. + - For details on the RACH test profiles, see B.6. + +## 7.7.5 Test Procedure + +The following table describes the test procedures for random access procedure. + +**Table 7.7-1: Random Access Procedure** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends Cell Configuration to O-DU. | <b>O-DU ← SMO</b> | Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC: <ul style="list-style-type: none"> <li>• PRACH Configuration</li> </ul> | +| 2 | Cell bring-up | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>Verify O-DU sends mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.<br>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify O-DU sets the administrative state to UNLOCKED state. <ul style="list-style-type: none"> <li>• Verify UE has decoded MIB and SIB1 after switch-on.</li> </ul> | +| 3 | The UE transmits a preamble on PRACH. | <b>UE → O-DU/O-CU</b> | Verify the UE transmits a preamble on PRACH using the preamble indicated by ra-PreambleStartIndex defined in SI-RequestConfig in SIB1 in <i>RACH Configuration</i> . | + +| | | | | +|---|-------------------------------------------------------------------------------------------------------------------------------|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>O-DU receives the preamble within the specified window as different preamble has specific PRACH Index.</p> <p>Verify MAC receives RACH Indication with following IEs:</p> <ul style="list-style-type: none"> <li>• Cell Index</li> <li>• Timing Information</li> <li>• Slot Index</li> <li>• Symbol Index</li> <li>• Frequency Index</li> <li>• Preamble ID</li> <li>• Timing Advance</li> </ul> | +| 4 | O-DU transmits an RAR message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify Random Access Response includes to UE RA-RNTI including a MAC subPDU with a matching RAPID only.</p> <ul style="list-style-type: none"> <li>• Verify SCH sends RAR Information to MAC with following IEs: Cell Index</li> <li>• Timing Information</li> <li>• RA_RNTI</li> <li>• Number of Preambles</li> <li>• RAPID</li> <li>• Timing Advance Value</li> <li>• Start RB</li> <li>• Number of RBs</li> <li>• Temporary CRNTI</li> </ul> | +| 5 | The UE sends RRCSetupRequest with random ue-identity and establishment cause (refer to the section 5.3.3 in 3GPP 38.331 [8]). | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC setup Request message from the UE and sends Initial UL RRC message to O-CU with RRC setup request message in RRC container.</p> <p>Verify all the mandatory IEs of Initial UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | +| 6 | UE receives RRCsetup message for SRB1 creation. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU sends DL RRC message transfer to O-DU with RRC setup message in the RRC container to establish SRB1.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends RRC setup message to UE.</p> <p>Verify all the mandatory IEs of RRC setup as per section 6.2.2 in 3GPP Specification. [8].</p> | +| 7 | UE sends RRC setup complete message over SRB1 with Registration Request as NAS payload. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC setup complete message with registration request as NAS payload from UE and sends UL RRC message transfer to O-CU with RRC setup complete and Registration Request message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Initial UE Message to AMF with NAS payload as Registration Request.</p> <p>Verify all the mandatory IEs of Initial UE message as per section 9.2.5.1 of 3GPP Specification [20].</p> | + +| | | | | +|---|-------------------|----------------|----------------------------------------| +| 8 | Attach validation | UE ↔ O-DU/O-CU | Verify successful UE attach procedure. | +|---|-------------------|----------------|----------------------------------------| + +## 7.8 ORAN.WG8.IOT.007: Registration Procedure + +### 7.8.1 Test Purpose + +The purpose of this test case is to verify the UE registration procedure in an end to end environment. This case illustrates that the UE changes its RRC state from idle to connected. + +### 7.8.2 Reference Requirements + +For detailed requirements, refer to the section Annex A – UE Registration in ORAN-WG8.AAD [1]. + +### 7.8.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- F1AP connection is successful between O-CU and O-DU. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. + +### 7.8.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A.1. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + +- For details on the RACH test profiles, see B.6. + +## 7.8.5 Test Procedure + +The following table below describes the test steps for Registration procedure + +**Table 7.8-1: Registration** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|----------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | The UE sends RRCSetupRequest with random ue-identity and establishment cause (refer to the section 5.3.3 in 3GPP 38.331 [8]). | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC setup Request message from the UE and sends Initial UL RRC message to O-CU with RRC setup request message in RRC container.</p> <p>Verify all the mandatory IEs of Initial UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | +| 2 | UE receives RRCsetup message for SRB1 creation. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU sends DL RRC message transfer to O-DU with RRC setup message in the RRC container to establish SRB1.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends RRC setup message to UE.</p> <p>Verify all the mandatory IEs of RRC setup as per section 6.2.2 in 3GPP Specification. [8].</p> | +| 3 | UE sends RRC setup complete message over SRB1 with Registration Request as NAS payload. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC setup complete message with registration request as NAS payload from UE and sends UL RRC message transfer to O-CU with RRC setup complete and Registration Request message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Initial UE Message to AMF with NAS payload as Registration Request.</p> <p>Verify all the mandatory IEs of Initial UE message as per section 9.2.5.1 of 3GPP Specification [20].</p> | +| 4 | UE receives NAS Authentication Request message from AMF with authentication parameters required for successfully authenticating the network. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives DL NAS Transport message with Authentication request as NAS payload.</p> <p>Verify that O-CU sends DL RRC Message Transfer to O-DU with NAS Authentication Request in the RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Authentication request message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> | +| 5 | UE sends NAS Authentication response message after successfully authenticating the network. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Authentication Response message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Authentication response in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | + +| | | | | +|----|------------------------------------------------------------------------------------------------|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify that O-CU sends UL NAS Transport message to AMF with Authentication Response as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 6 | UE receives NAS Security mode command message for integrity protection and ciphering. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives DL NAS Transport message with security mode command as NAS payload.</p> <p>Verify that O-CU sends DL RRC Message Transfer to O-DU with NAS Security mode command in the RRC container<br/>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Security mode command message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> | +| 7 | UE sends NAS Security mode complete message. This message is integrity protected and ciphered. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Security mode complete message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Security mode complete message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Security mode complete as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 8 | UE receives AS security mode command message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives Initial context setup request or DL NAS Transport from AMF with Registration accept as NAS payload.</p> <p>Verify all the mandatory IEs as per the section 9.2.2.1 or 9.2.5.2 in 3GPP Specification [20].</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU with AS security mode command message in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify the O-DU sends SecurityModeCommand to UE which contains AS integrity and Ciphering Algorithms supported by O-CU.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> | +| 9 | UE sends AS Security mode complete message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify in response of previous step, the O-DU receives SecurityModeComplete from UE.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains AS security mode complete in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | +| 10 | UE receives UE capability Enquiry message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives the UE radio capability check request from AMF to check the compatibility between UE radio capabilities and network configuration.</p> | + +| | | | | +|----|---------------------------------------------|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>O-CU can optionally request for the UE capability enquiry to the UE.</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU which contains UE capability enquiry in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends UE capability enquiry to UE to check the UE capabilities.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> | +| 11 | UE sends UE capability information message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify in response of previous step, the O-DU receives UE capability information from UE.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains UE capability information in the RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UE Radio Capability Info Indication message to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.13.1 in 3GPP Specification [20].</p> | +| 12 | UE receives Registration Accept message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU sends DL RRC message transfer to O-DU which contains Registration Accept in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Registration accept message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> | +| 13 | UE sends Registration complete message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Registration complete message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Registration complete message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Initial context setup response to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.2.2 in 3GPP Specification [20].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Registration complete as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | + +## 7.9 ORAN.WG8.IOT.008: UE Initiated De-Registration Procedure + +### 7.9.1 Test Purpose + +The purpose of this test case is to verify the UE Initiated De-registration procedure in an end to end environment. This case illustrates that the UE changes its RRC state from connected to idle. + +### 7.9.2 Reference Requirements + +For detailed requirements, refer to the section Annex A – UE Registration in ORAN-WG8.AAD [1]. + +### 7.9.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup procedure is successful. +- UE Registration procedure is successful. + +### 7.9.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A.1. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.9.5 Test Procedure + +The following table below describes the test steps for De-registration procedure. + +**Table 7.9-1: UE initiated De-registration** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|------------------------------------------------------------------------------------------------------------------------|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | The UE sends De-registration request with SUCI or 5G-GUTI (refer to the section 8.2.12.1 in 3GPP Specification [21] ). | <b>UE → O-DU/ O-CU</b> | <p>Verify that O-DU receives the UL information transfer message which contains NAS De-registration message.</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU with De-registration request in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Uplink NAS transport with NAS PDU as De-registration request to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 2 | UE receives De-registration accept message. | <b>UE ← O-DU/ O-CU</b> | <p>Verify that O-CU receives Downlink NAS transport with NAS PDU as De-registration accept from AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.5.2 in 3GPP Specification [20].</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU with De-registration accept in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS De-registration accept message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> <p>Verify that O-CU receives the UE context release command from AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.2.5 in 3GPP Specification [20].</p> <p>Verify that O-CU sends UE context release command message to O-DU.</p> <p>Verify all the mandatory IEs as per section 6.2.1.2 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends UE context release complete to O-CU on F1 interface.</p> <p>Verify all the mandatory IEs as per section 6.2.1.2 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UE context release complete to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.2.6 in 3GPP Specification [20].</p> | +| 3 | UE receives RRC Connection Release. | <b>UE ← O-DU/ O-CU</b> | O-CU sends DL RRC message transfer to O-DU. | + +| | | | | +|--|--|--|--------------------------------------------------| +| | | | O-DU sends RRC Connection Release message to UE. | +|--|--|--|--------------------------------------------------| + +## 7.10 ORAN.WG8.IOT.009: PDU session establishment procedure + +### 7.10.1 Test Purpose + +The purpose of this test case is to verify the UE PDU session establishment procedure in an end to end environment. This case illustrates that the UE will be assigned a PDU IP after successful establishment of PDU session. + +### 7.10.2 Reference Requirements + +For detailed requirements, refer to the section Annex A – PDU Session Establishment in ORAN-WG8.AAD [1]. + +### 7.10.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- F1AP connection is successful between O-DU and O-CU. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup is successful. +- Registration is successful. + +### 7.10.4 Test Setup and Configuration + +- DUTs: single O-DU and single O-CU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + +- For details on the test setup refer Annex A.1. +- For details on the MIB and SSB test profiles, see B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.10.5 Test Procedure + +The following table below describes the test steps for PDU session establishment procedure. + +**Table 7.10-1: PDU session establishment** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------------------------------------------------------------------------------|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | The UE sends PDU session Establishment Request with PDU session id (refer to the section 8.3.1 in 3GPP Specification [21]). | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UL information transfer message which contains PDU session establishment request as NAS message.</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains PDU session establishment request in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Uplink NAS transport with NAS PDU as PDU Session Establishment Request to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 2 | UE receives RRC reconfiguration and PDU session establishment accept message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives PDU Session Resource Setup Request from AMF with NAS-PDU as PDU session establishment accept.</p> <p>Verify all the mandatory IEs as per section 9.2.1.1 in 3GPP Specification [20].</p> <p>Verify that O-CU sends UE context setup request to O-DU for establishing the DRB.</p> <p>Verify all the mandatory IEs of UE context setup request as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends UE context setup response to O-CU after successfully establishing the DRB.</p> <p>Verify all the mandatory IEs of UE context setup response as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU with RRC reconfiguration in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends RRC reconfiguration message to UE which contains PDU session establishment accept as NAS payload.</p> | + +| | | | | +|---|----------------------------------------|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3 | UE sends RRC reconfiguration complete. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives RRC reconfiguration complete from UE.</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU with RRC reconfiguration complete in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends PDU Session Resource Setup Response to AMF over NG interface.</p> <p>Verify all the mandatory IEs as per section 9.2.1.2 in 3GPP Specification [20].</p> | +|---|----------------------------------------|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +## 7.11 ORAN.WG8.IOT.010: PDU Session Modification with Multiple Flow + +### 7.11.1 Test Purpose + +The purpose of this test case is to verify the network initiated PDU Modification procedure in an end to end environment. This test case illustrates the Network Initiated Modification of PDU Session with by adding one GBR Flow of 5QI 3 and one Non GBR Flow of 5QI 6. + +### 7.11.2 Reference Requirements + +For detailed requirements, refer to the section Annex A – PDU Session Establishment in ORAN-WG8.AAD [1]. + +### 7.11.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- F1AP connection is successful between O-DU and O-CU. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup is successful. +- Registration is successful with Follow ON bit as 1. +- UE initiated PDU session establishment procedure is successful. + +### 7.11.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. + +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2, and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A.1. +- For details on the MIB and SSB test profiles, see B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.11.5 Test Procedure + +The following table below describes the test steps for network initiated PDU Modification procedure + +**Table 7.11-1: PDU session modification** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------------------------------------|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | AMF sends NGAP PDU Session Resource Modify Request to O-CU. | <b>O-CU/O-DU<br/>← AMF</b> | <p>Verify that O-CU receives sends NGAP PDU Session Resource Modify Request message which contains the Information about the PDU Session and the flow which the 5G CN wants to add.</p> <p>NGAP PDU Session Resource Modify Request contains all the Mandatory IEs mentioned in the section 9.2.1.5 and 9.3.4.3 of 3GPP Specification [20].</p> <p>Verify that O-CU sends F1AP UE Context Modification Request message to O-DU.</p> <p>F1AP UE Context Modification Request message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends F1AP UE Context Modification Response message to O-CU.</p> <p>F1AP UE Context Modification Response message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends F1AP DL RRC Message Transfer Request with RRC reconfiguration message in RRC container to O-DU and the message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 2 | UE receives RRC reconfiguration and 5G SM: PDU session Modification Command message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-DU sends RRC reconfiguration message to UE and the RRC Reconfiguration message contains all the mandatory IEs mentioned in the 3GPP Specification [8].</p> | + +| | | | | +|---|--------------------------------------------------------------------------------------------------------------|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3 | UE sends RRC Reconfiguration Complete. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC Reconfiguration Complete message and sends F1AP UL RRC message transfer to O-CU which contains RRC Reconfiguration Complete inside RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | +| 4 | O-CU sends NGAP PDU Session Resource Modify Response message to AMF. | <b>O-DU/O-CU<br/>→ AMF</b> | <p>Verify that AMF receives the NGAP PDU Session Resource Modify Response.</p> <p>NGAP PDU Session Resource Modify Response contains all the Mandatory IEs mentioned in the section 9.2.1.6 and 9.3.4.3 of 3GPP Specification [20].</p> <p>Verify that O-CU sends F1AP UE Context Modification Request to O-DU.</p> <p>F1AP UE Context Modification Request message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends F1AP UE Context Modification Response message to O-CU.</p> <p>F1AP UE Context Modification Response message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 5 | UE sends UL Information Transfer message containing the NAS message 5GSM: PDU Session Modification Complete. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the sends UL Information Transfer message and sends UL RRC message transfer to O-CU.</p> <p>Verify that O-CU sends NGAP Uplink NAS Transport Message to AMF with NAS payload as 5GSM: PDU Session Modification Complete.</p> | + +## 7.12 ORAN.WG8.IOT.011: Idle Mode Paging and Service Request Procedure + +### 7.12.1 Test Purpose + +The purpose of this test case is to verify the UE idle mode paging and Service Request procedure in an end to end environment. This test case illustrates the UE transition from RRC Idle state to RRC Connected state. + +### 7.12.2 Reference Requirements + +For detailed requirements, refer to the section 4.2 in ORAN-WG8.AAD [1]. + +### 7.12.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- F1AP connection is successful between O-DU and O-CU. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup is successful. +- Registration is successful. +- UE moves to RRC-Idle state. + +## 7.12.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A.1. +- For details on the MIB and SSB test profiles, see B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.12.5 Test Procedure + +The following table below describes the test steps for Idle mode paging and Service Request procedure + +**Table 7.12-1: Idle mode Paging & Service Request** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|----------------------------------------------------------------|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | The UE moves to RRC-IDLE state and DL data is received at UPF. | <b>UE ← O-DU/<br/>O-CU</b> | Verify that O-CU receives Paging message from AMF over NG interface.<br><br>Verify all the mandatory IEs as per section 9.2.4 in 3GPP Specification [20]. | +| 2 | UE receives paging message. | <b>UE ← O-DU/<br/>O-CU</b> | Verify that O-CU sends Paging message to O-DU over F1 interface. | + +| | | | | +|---|------------------------------------------------------------------------------------|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify all the mandatory IEs as per section 9.2.6 in 3GPP Specification [2].</p> <p>Verify that O-DU sends Paging message to UE.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> | +| 3 | UE sends RRC setup request with S-TMSI. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC setup request message and sends Initial UL RRC message transfer to O-CU which contains RRC setup request message in RRC container.</p> <p>Verify all the mandatory IEs of Initial UL RRC message transfer as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | +| 4 | UE receives RRC setup message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU sends DL RRC message transfer to O-DU with RRC setup message in the RRC container to establish SRB1.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends RRC setup message to UE.</p> <p>Verify all the mandatory IEs of RRC setup as per section 6.2.2 in 3GPP Specification. [8].</p> | +| 5 | UE sends RRC setup complete message over SRB1 with Service Request as NAS payload. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC setup complete message with Service request as NAS payload from UE and sends UL RRC message transfer to O-CU with RRC setup complete and Service Request message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Initial UE Message to AMF with NAS payload as Service Request.</p> <p>Verify all the mandatory IEs of Initial UE message as per section 9.2.5.1 of 3GPP Specification [20].</p> | +| 6 | UE receives RRC reconfiguration with Service Accept message as NAS payload. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives Initial context setup request message with NAS payload as service accept.</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU which contains RRC reconfiguration and service accept messages in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends RRC Reconfiguration message which contains Service accept as NAS payload.</p> <p>Verify all the mandatory IEs of RRC reconfiguration message as per section 6.2.2 in 3GPP Specification [8].</p> | +| 7 | UE sends RRC reconfiguration complete message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC Reconfiguration complete message and sends UL RRC Message</p> | + +| | | | | +|--|--|--|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>transfer to O-CU which contains RRC reconfiguration complete in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Initial context setup response message to AMF.</p> <p>Verify all the mandatory IEs of Initial context setup response message as per section 9.2.2.2 in 3GPP Specification [20].</p> | +|--|--|--|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +## 7.13 ORAN.WG8.IOT.012: Downlink UDP data transfer + +### 7.13.1 Test Purpose + +The purpose of this test case is to verify peak and average downlink throughput on the default flow that is 5QI 9 of the PDU Session. + +### 7.13.2 Reference Requirements + +For detailed requirements, refer to the section 4.2 in ORAN-WG8.AAD [1]. + +### 7.13.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- F1AP connection is successful between O-DU and O-CU. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup is successful. +- Registration is successful with Follow ON bit as 1. +- UE PDU session establishment procedure with 5QI 9 is successful. + +### 7.13.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. + +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A.1. +- For details on the RACH test profiles, see B.6. +- For details on the MIB and SSB test profiles, see B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the throughput test profiles, see B.7. + +## 7.13.5 Test Procedure + +The following table describes the test procedures for downlink continuous throughput. + +**Table 7.13-1: Downlink Continuous Throughput** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------------------------|-----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Trigger UDP Data of transfer 712 Mbps in Downlink on the flow of 5QI 9 using any traffic generator tool or IPERF application. | <b>O-CU/ O-DU<br/>← UPF</b> | Verify that O-CU receives DL UDP traffic on the desired Flow on the intendant NG-U connection.<br><br>O-CU do the mapping of the Flow to the intendant DRB which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic towards O-DU.<br><br>Verify that O-DU received the UDP traffic without any significant drops in packets. | +| 2 | Measure peak and average throughput on UE. | <b>UE ← O-DU/<br/>O-CU</b> | Verify against theoretical values. Refer Annex B.7. | + +## 7.14 ORAN.WG8.IOT.013: Uplink UDP data transfer + +### 7.14.1 Test Purpose + +The purpose of this test case is to verify peak and average uplink throughput on the default flow that is 5QI 9 of the PDU Session. + +### 7.14.2 Reference Requirements + +For detailed requirements, refer to the section 4.2 in ORAN-WG8.AAD [1]. + +### 7.14.3 Initial Condition + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. + +- F1AP connection is successful between O-DU and O-CU. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup is successful. +- Registration is successful with Follow ON bit as 1. +- UE PDU session establishment procedure with 5QI 9 is successful. + +## 7.14.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A.1 and A.2. + - For details on the RACH test profiles, see B.6. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the throughput test profiles, see B.7. + +## 7.14.5 Test Procedure + +The following table describes the test procedures for uplink continuous throughput. + +**Table 7.14-1: Uplink Continuous Throughput** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|-----------------------------------------------------------------------------------------------------------------------------|-----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Trigger UDP Data transfer of 285 Mbps in Uplink on the flow of 5QI 9 using any traffic generator tool or IPERF application. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UL UDP traffic on the desired DRB which is intended and forwards to O-CU using the GTP-U user plane connection.</p> <p>O-CU do the mapping of the DRB to Flow mapping which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic on the NG-U tunnel towards UPF.</p> <p>Verify that UPF received the UDP traffic without any significant drops in packets.</p> | +| 2 | Measure peak and average throughput on UE. | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify against theoretical values. Refer Annex B.7. | + +## 7.15 ORAN.WG8.IOT.014: Bidirectional UDP data transfer + +### 7.15.1 Test Purpose + +The purpose of this test case is to verify peak and average uplink and downlink throughput on the default flow that is 5QI 9 of the PDU Session. + +### 7.15.2 Reference Requirements + +For detailed requirements, refer to the section 4.2 in ORAN-WG8.AAD [1]. + +### 7.15.3 Initial Condition + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- F1AP connection is successful between O-DU and O-CU. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup is successful. +- Registration is successful with Follow ON bit as 1. +- UE PDU session establishment procedure with 5QI 9 is successful. + +### 7.15.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. + +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A.1 and A.2. +- For details on the RACH test profiles, see B.6. +- For details on the MIB and SSB test profiles, see B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the throughput test profiles, see B.7. + +## 7.15.5 Test Procedure + +The following table describes the test procedures for bidirectional continuous throughput. + +**Table 7.15-1: Bidirectional Continuous Throughput** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------------------------|-----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Trigger UDP Data transfer of 285 Mbps in Uplink on the flow of 5QI 9 using any traffic generator tool or IPERF application. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UL UDP traffic on the desired DRB which is intended and forwards to O-CU using the GTP-U user plane connection.</p> <p>O-CU do the mapping of the DRB to Flow mapping which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic on the NG-U tunnel towards UPF.</p> <p>Verify that UPF received the UDP traffic without any significant drops in packets.</p> | +| 2 | Verify the peak and average throughput on UPF. | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify against theoretical values. Refer Annex B.7. | +| 3 | Trigger UDP Data of transfer 712 Mbps in Downlink on the flow of 5QI 9 using any traffic generator tool or IPERF application. | <b>O-CU/ O-DU<br/>← UPF</b> | <p>Verify that O-CU receives DL UDP traffic on the desired Flow on the intended NG-U connection.</p> <p>O-CU do the mapping of the Flow to the intended DRB which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic towards O-DU.</p> <p>Verify that O-DU received the UDP traffic without any significant drops in packets.</p> | +| 4 | Measure peak and average throughput on UE. | <b>UE ← O-DU/<br/>O-CU</b> | Verify against theoretical values. Refer Annex B.7. | + +## 7.16 ORAN.WG8.IOT.015: Bidirectional UDP data transfer on Multiple Flow + +### 7.16.1 Test Purpose + +The purpose of this test case is to verify peak and average downlink and uplink throughput on multiple flows of a PDU Session for two hours. + +### 7.16.2 Reference Requirements + +For detailed requirements, refer to the section 4.2 in ORAN-WG8.AAD [1]. + +### 7.16.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- F1AP connection is successful between O-DU and O-CU. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup is successful. +- Registration is successful with Follow ON bit as 1. +- UE PDU session establishment procedure with 5QI 9 is successful. +- The Network Initiated Modification of PDU Session for adding one GBR Flow of 5QI 3 and one Non GBR Flow of 5QI 6 is successful. + +### 7.16.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A.1 and A.2. + +- For details on the RACH test profiles, see B.6. +- For details on the MIB and SSB test profiles, see B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the test throughput test profiles, see B.7. + +## 7.16.5 Test Procedure + +The following table below describes the test procedures for bidirectional continuous throughput. + +**Table 7.16-1: Bidirectional UDP data on multiple flow** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------------------------|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Trigger UDP Data transfer of 100 Mbps in Uplink on the flow of 5QI 9 using any traffic generator tool or IPERF application. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UL UDP traffic on the desired DRB which is intendand and forwards to O-CU using the GTP-U user plane connection.</p> <p>O-CU do the mapping of the DRB to Flow mapping which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic on the NG-U tunnel towards UPF.</p> <p>Verify that UPF received the UDP traffic without any significant drops in packets.</p> | +| 2 | Verify the peak and average throughput on UPF. | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify that the data has been received as pumped from UE. | +| 3 | Trigger UDP Data of transfer 300 Mbps in Downlink on the flow of 5QI 9 using any traffic generator tool or IPERF application. | <b>O-CU/ O-DU<br/>← UPF</b> | <p>Verify that O-CU receives DL UDP traffic on the desired Flow on the intendand NG-U connection.</p> <p>O-CU do the mapping of the Flow to the intendand DRB which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic towards O-DU.</p> <p>Verify that O-DU received the UDP traffic without any significant drops in packets.</p> | +| 4 | Measure peak and average throughput on UE. | <b>UE ← O-DU/<br/>O-CU</b> | Verify that the data has been received as pumped from UPF. | +| 5 | Trigger UDP Data transfer of 90 Mbps in Uplink on the flow of 5QI 3 using any traffic generator tool or IPERF application. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UL UDP traffic on the desired DRB which is intendand and forwards to O-CU using the GTP-U user plane connection.</p> <p>O-CU do the mapping of the DRB to Flow mapping which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic on the NG-U tunnel towards UPF.</p> <p>Verify that UPF received the UDP traffic without any significant drops in packets.</p> | +| 6 | Verify the peak and average throughput on UPF. | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify that the data has been received as pumped from UE. | + +| | | | | +|----|-------------------------------------------------------------------------------------------------------------------------------|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 7 | Trigger UDP Data of transfer 200 Mbps in Downlink on the flow of 5QI 3 using any traffic generator tool or IPERF application. | <b>O-CU/ O-DU<br/>← UPF</b> | <p>Verify that O-CU receives DL UDP traffic on the desired Flow on the intendant NG-U connection.</p> <p>O-CU do the mapping of the Flow to the intendant DRB which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic towards O-DU.</p> <p>Verify that O-DU received the UDP traffic without any significant drops in packets.</p> | +| 8 | Measure peak and average throughput on UE. | <b>UE ← O-DU/<br/>O-CU</b> | Verify that the data has been received as pumped from UPF. | +| 9 | Trigger UDP Data transfer of 80 Mbps in Uplink on the flow of 5QI 6 using any traffic generator tool or IPERF application. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UL UDP traffic on the desired DRB which is intendant and forwards to O-CU using the GTP-U user plane connection.</p> <p>O-CU do the mapping of the DRB to Flow mapping which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic on the NG-U tunnel towards UPF.</p> <p>Verify that UPF received the UDP traffic without any significant drops in packets.</p> | +| 10 | Verify the peak and average throughput on UPF. | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify that the data has been received as pumped from UE. | +| 11 | Trigger UDP Data of transfer 200 Mbps in Downlink on the flow of 5QI 6 using any traffic generator tool or IPERF application. | <b>O-CU/ O-DU<br/>← UPF</b> | <p>Verify that O-CU receives DL UDP traffic on the desired Flow on the intendant NG-U connection.</p> <p>O-CU do the mapping of the Flow to the intendant DRB which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic towards O-DU.</p> <p>Verify that O-DU received the UDP traffic without any significant drops in packets.</p> | +| 12 | Measure peak and average throughput on UE. | <b>UE ← O-DU/<br/>O-CU</b> | Verify that the data has been received as pumped from UPF. | + +## 7.17 ORAN.WG8.IOT.016: SMO Discovery and O1 Interface establishment between O-DU and SMO using static configuration on the O-DU. + +### 7.17.1 Test Purpose + +The purpose of this test case is to verify the successful establishment of link between O-DU and SMO using static configuration in the O-DU and verify the yang capability model exchange between the SMO and O-DU using O1 Interface. + +## 7.17.2 Reference Requirements + +For detailed requirements, refer to the section 6 in ORAN-WG8.AAD [1]. + +## 7.17.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of CA/RA server, SMO, O-DU and O-RU is connected. (Note: If CA/RA server is not present, O-DU is able to send with the default certificates to SMO for secure connection establishment). +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- NETCONF Client is operational. +- O-DUs are able to get the static IP address during the power ON and O-DU obtains pre-configured SMO IP address using static configuration file on O-DU. + +## 7.17.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: +- Test UEs or UE emulator which can support NR. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.4. + +## 7.17.5 Test Procedure + +The following table describes the test procedures for successful establishment of link between O-DU and SMO using static configuration and verify the yang capability model exchange between the SMO and O-DU using O1 Interface. + +**Table 7.17-1: SMO Discovery and O1 Interface establishment between O-DU and SMO using static configuration in O-DU.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|-------------------------------------------------------------------------------------------------------------------|------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Power ON O-DU. | O-DU | Verify O-DU obtain the static IP address using factory settings.<br><br>Verify O-DU obtain the SMO IP address as per the static configuration file present in O-DU. | +| 2 | O-DU sends Pnfdregistration to SMO. | O-DU → SMO | Verify O-DU sends Pnfdregistration message to SMO IP address mention in the configuration file of O-DU containing all the mandatory IEs. | +| 3 | SMO sends TLS secure connection establishment to O-DU. | O-DU ← SMO | Verify the TLS secure connection is established between SMO and O-DU as per [22]. Verify SMO sends the NETCONF capabilities supported to O-DU in hello message. | +| 4 | O-DU sends Netconf capability information to SMO and secured NETCONF session is established between SMO and O-DU. | O-DU → SMO | Verify O-DU sends the NETCONF capabilities supported to SMO in hello message. | +| 5 | SMO sends HeartBeat message to O-DU. | O-DU ← SMO | Verify SMO sends HeartBeat message to O-DU. | +| 6 | O-DU sends HeartBeat Acknowledgment to SMO. | O-DU → SMO | Verify O-DU sends HeartBeat Acknowledgment to SMO. | + +## 7.18 ORAN.WG8.IOT.017: SMO Discovery and O1 Interface establishment between O-DU and SMO. + +### 7.18.1 Test Purpose + +The purpose of this test case is to verify the successful establishment of link between O-DU and SMO and verify the yang capability model exchange between the SMO and O-DU using O1 Interface. + +### 7.18.2 Reference Requirements + +For detailed requirements, refer to the section 6 in ORAN-WG8.AAD [1]. + +### 7.18.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. + +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. + +## 7.18.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + +## 7.18.5 Test Procedure + +The following table describes the test procedures for successful establishment of link between O-DU and SMO and verify the yang capability model exchange between the SMO and O-DU using O1 Interface. + +**Table 7.18-1: SMO Discovery and O1 Interface establishment between O-DU and SMO** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------------|------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | O-DU sends Pnregistration to SMO. | O-DU → SMO | Verify O-DU sends Pnregistration message containing all the mandatory IEs. | +| 2 | SMO sends TLS secure connection establishment to O-DU. | O-DU ← SMO | Verify the TLS secure connection is established between SMO and O-DU as per [22]. Verify SMO sends the NETCONF capabilities supported to O-DU in hello message. | +| 3 | O-DU sends Netconf capability information to SMO and secured NETCONF session is established between SMO and O-DU. | O-DU → SMO | Verify O-DU sends the NETCONF capabilities supported to SMO in hello message. | +| 4 | SMO sends HeartBeat message to O-DU. | O-DU ← SMO | Verify SMO sends HeartBeat message is send to O-DU. | +| 5 | O-DU sends HeartBeat Acknowledgment to SMO. | O-DU → SMO | Verify O-DU sends HeartBeat Acknowledgment to SMO. | + +## 7.19 ORAN.WG8.IOT.018: Verify the cell activation successful when configuration received from SMO for co-located O-RU and O-DU. + +### 7.19.1 Test Purpose + +The purpose of this test case is to verify the successful cell activation when configuration received from SMO for co-located O-RU and O-DU. + +### 7.19.2 Reference Requirements + +For detailed requirements, refer to the section 6 in ORAN-WG8.AAD [1]. + +### 7.19.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is co-located with O-DU. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU are exchanging the information using O-RU management approach. + +### 7.19.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: +- Test UEs or UE emulator which can support NR. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, NAS, HTTP2, PFCP protocol content. + +- Configuration: +- For details on the test setup refer Annex A - A.5. + +## 7.19.5 Test Procedure + +The following table describes the test procedures to verify the successful cell activation when configuration received from SMO for co-located O-DU and O-RU. + +**Table 7.19-1: cell activation when configuration received from SMO for co-located O-DU and O-RU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------|-------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends Cell Configuration to O-DU. | O-DU ← SMO | Verify SMO sends all the mandatory IEs to O-DU as per the data formats supported in Section 12.2 of [22]. | +| 2 | O-DU sends sync-state information and set the operational state in SMO. | O-DU → SMO | Verify O-DU sends the sync-state as LOCKED to SMO. Verify O-DU set the operational state to ENABLED state. | +| 3 | SMO sets the administrate state of O-DU. | O-DU ← SMO | Verify O-DU sets the administrative state to UNLOCKED state. | +| 4 | O-DU sends an F1 SETUP REQUEST to establish connectivity between the O-DU and O-CU. | O-DU → O-CU | Verify O-DU sends F1 SETUP REQUEST message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-CU-CP (Control Unit). | +| 5 | O-CU sends NGAP Setup Request to AMF. | O-CU → AMF | Verify the NGAP Setup Request contains all the mandatory IEs mentioned in the section 9.2.6.1 of 3GPP Specification [20]. | +| 6 | O-CU receives NGAP Setup Response from AMF. | O-CU ← AMF | Verify AMF sends NGAP Setup Response message containing all the mandatory IEs mentioned in 9.2.6.1 of 3GPP Specification [20]. | +| 7 | O-DU receives F1 SETUP RESPONSE from O-CU. | O-DU ← O-CU | Verify O-CU sends F1 SETUP RESPONSE message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-DU. | +| 8 | Cell Bring-up is initiated at O-CU. | O-DU ← O-CU | O-CU sends the F1AP gNB-CU configuration update to O-DU.<br><br>F1AP gNB-CU configuration update message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].<br><br>O-CU adds the cell information according to IE Served-Cells-To-Add-List. | +| 9 | O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU. | O-DU → O-CU | Verify O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU.<br><br>F1AP gNB-CU configuration update Ack message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19]. | +| 10 | Activate the cell from the O-DU. | O-DU → O-CU | O-DU sends the F1AP gNB-DU configuration update to O-CU.<br><br>F1AP gNB-DU configuration update message contains all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19]. | + +| | | | | +|----|-------------------------------------------------------------------------|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | O-DU activates the cell information according to the service-state IE. | +| 11 | O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU. | <b>O-DU ← O-CU</b> | Verify O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU.<br><br>F1AP gNB-DU configuration update Ack message contains all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19]. | +| 12 | Verify the status of the cell. | <b>O-DU/O-CU</b> | Verify SMO shows O-CU and O-DU operational and newly added cell is up and RF state of O-RU is active. | + +## 7.20 ORAN.WG8.IOT.019: Verify the cell activation successful when configuration received from SMO for non co-located(remote) O-RU and O-DU. + +### 7.20.1 Test Purpose + +The purpose of this test case is to verify the successful cell activation when configuration received from SMO for non co-located(remote) O-RU and O-DU. + +### 7.20.2 Reference Requirements + +For detailed requirements, refer to the Section 6 in ORAN-WG8.AAD [1]. + +### 7.20.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. + +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.20.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + +## 7.20.5 Test Procedure + +The following table describes the test procedures to verify the successful cell activation when configuration received from SMO for non co-located(remote) O-RU and O-DU. + +**Table 7.20-1: Cell activation when configuration received from SMO for non co-located(remote) O-RU and O-DU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------|-------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends Cell Configuration to O-DU. | SMO → O-DU | Verify SMO sends all the mandatory IEs to O-DU as per the data formats supported in Section 12.2 of [22]. | +| 2 | O-DU sends the Cell Configuration to O-RU. | O-DU → O-RU | Verify O-DU sends all the mandatory IEs to O-RU as per the data formats supported in Section 12.2 of [22].<br><br>Verify O-RU updates mandatory cell configuration and changes its carrier-state to ACTIVE. | +| 3 | O-RU sends sync-state information to O-DU. | O-DU ← O-RU | Verify O-RU sends the sync-state as LOCKED to O-DU. | +| 4 | O-DU sends sync-state information and set the operational state in SMO. | O-DU → SMO | Verify O-DU sends the sync-state as LOCKED to SMO. Verify O-DU set the operational state to ENABLED state. | +| 6 | SMO sets the administrate state of O-DU. | SMO → O-DU | O-DU sets the administrative state to UNLOCKED state. | + +| | | | | +|----|-------------------------------------------------------------------------------------|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 7 | O-DU sends an F1 SETUP REQUEST to establish connectivity between the O-DU and O-CU. | <b>O-DU → O-CU</b> | Verify O-DU sends F1 SETUP REQUEST message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-CU-CP (Control Unit) | +| 8 | O-CU sends NGAP Setup Request to AMF. | <b>O-CU → AMF</b> | Verify the NGAP Setup Request contains all the mandatory IEs mentioned in the section 9.2.6.1 of 3GPP Specification [20]. | +| 9 | O-CU receives NGAP Setup Response from AMF. | <b>O-CU ← AMF</b> | Verify AMF sends NGAP Setup Response message containing all the mandatory IEs mentioned in 9.2.6.1 of 3GPP Specification [20]. | +| 10 | O-DU receives F1 SETUP RESPONSE from O-CU. | <b>O-DU ← O-CU</b> | Verify O-CU sends F1 SETUP RESPONSE message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-DU. | +| 11 | Cell Bring-up is initiated at O-CU. | <b>O-DU ← O-CU</b> | <p>O-CU sends the F1AP gNB-CU configuration update to O-DU.</p> <p>F1AP gNB-CU configuration update message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>O-CU adds the cell information according to IE Served-Cells-To-Add-List.</p> | +| 12 | O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU. | <b>O-DU → O-CU</b> | <p>Verify O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU.</p> <p>F1AP gNB-CU configuration update Ack message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 13 | Activate the cell from the O-DU. | <b>O-DU → O-CU</b> | <p>O-DU sends the F1AP gNB-DU configuration update to O-CU.</p> <p>F1AP gNB-DU configuration update message contains all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> <p>O-DU activates the cell information according to the service-state IE.</p> | +| 14 | O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU. | <b>O-DU ← O-CU</b> | <p>Verify O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU.</p> <p>F1AP gNB-DU configuration update Ack message contains all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> | +| 15 | Verify the status of the cell. | <b>O-DU/O-CU</b> | <p>Verify O-DU is UP and O-RU changes its state to RUNNING.</p> <p>Verify SMO shows O-CU and O-DU operational and newly added cell is up and RF state of O-RU is ACTIVE.</p> | + +## 7.21 ORAN.WG8.IOT.020: Verify SMO is notified with the alarm when O-DU detects out of sync from O-RU in hierarchical model. + +### 7.21.1 Test Purpose + +The purpose of this test case is to verify SMO is notified with the alarm when O-DU detects out of sync from O-RU in hierarchical model. + +### 7.21.2 Reference Requirements + +For detailed requirements, refer to the Section 6 in ORAN-WG8.AAD [1]. + +### 7.21.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.018. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.21.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. + +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.4. + +## 7.21.5 Test Procedure + +The following table describes the test procedures to verify SMO is notified with the alarm when O-DU detects out of sync from O-RU in hierarchical model. + +**Table 7.21-1: SMO is notified with the alarm when O-DU detects out of sync from O-RU in hierarchical model** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------|-------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends Cell Configuration to O-DU. | SMO → O-DU | Verify SMO sends all the mandatory IEs to O-DU as per the data formats supported in Section 12.2 of [22]. | +| 2 | O-DU sends the Cell Configuration to O-RU. | O-DU → O-RU | Verify O-DU sends all the mandatory IEs to O-RU as per the data formats supported in Section 12.2 of [22]. | +| 3 | O-RU sends sync-state information to O-DU. | O-DU ← O-RU | Verify O-RU sends the sync-state as LOCKED to O-DU. | +| 4 | O-DU sends sync-state information to SMO and O-DU sets the operational state. | O-DU → SMO | Verify O-DU sends the sync-state as LOCKED to SMO and verify O-DU sets the operational state to ENBALED state. | +| 5 | SMO sets the administrate state to O-DU. | SMO → O-DU | O-DU sets the administrative state to UNLOCKED state. | +| 6 | O-DU sends an F1 SETUP REQUEST to establish connectivity between the O-DU and O-CU. | O-DU → O-CU | Verify O-DU sends F1 SETUP REQUEST message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-CU-CP (Control Unit). | +| 7 | O-CU sends NGAP Setup Request to AMF. | O-CU → AMF | Verify the NGAP Setup Request contains all the mandatory IEs mentioned in the section 9.2.6.1 of 3GPP Specification [20]. | +| 8 | O-CU receives NGAP Setup Response from AMF. | O-CU ← AMF | Verify AMF sends NGAP Setup Response message containing all the mandatory IEs mentioned in 9.2.6.1 of 3GPP Specification [20]. | +| 9 | O-DU receives F1 SETUP RESPONSE from O-CU. | O-DU ← O-CU | Verify O-CU sends F1 SETUP RESPONSE message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-DU. | +| 10 | Cell Bring-up is initiated at O-CU. | O-DU ← O-CU | O-CU sends the F1AP gNB-CU configuration update to O-DU. | + +| | | | | +|----|-------------------------------------------------------------------------|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>F1AP gNB-CU configuration update message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>O-CU adds the cell information according to IE Served-Cells-To-Add-List.</p> | +| 11 | O-DU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU. | <b>O-DU → O-CU</b> | <p>Verify O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU.</p> <p>F1AP gNB-CU configuration update Ack message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 12 | Activate the cell from the O-DU. | <b>O-DU → O-CU</b> | <p>O-DU sends the F1AP gNB-DU configuration update to O-CU.</p> <p>F1AP gNB-DU configuration update message contains all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> <p>O-DU activates the cell information according to the service-state IE.</p> | +| 13 | O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU. | <b>O-DU ← O-CU</b> | <p>Verify O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU.</p> <p>F1AP gNB-DU configuration update Ack message contains all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> | +| 14 | Verify the status of the cell. | <b>O-DU</b> | <p>Verify SMO shows O-CU and O-DU operational and newly cell up and RF state of O-RU is ACTIVE.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication.</p> | +| 15 | O-DU detects sync loss with the O-RU. | <b>O-RU → O-DU</b> | Verify O-DU sends the alarm notification as per Annex A of [24]. (Example: Fault id:28). | +| 16 | O-DU sets the operational state to correct value. | <b>O-DU</b> | Verify O-DU set the operation state to DISABLED. | +| 17 | SMO sets the administrate state to O-DU. | <b>SMO → O-DU</b> | O-DU sets the administrative state to LOCKED state. | + +## 7.22 ORAN.WG8.IOT.021: Verify SMO sends subscription to O-RU via O-DU for alarms and handles the alarm notification from O-RU via O-DU. + +### 7.22.1 Test Purpose + +The purpose of this test case is to verify SMO sends subscription for alarms to O-RU via O-DU and handles the alarm notification from O-RU via O-DU in hierarchical model. + +## 7.22.2 Reference Requirements + +For detailed requirements, refer to the Section 6 in ORAN-WG8.AAD [1]. + +## 7.22.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.018. +- O-DU and O-RU are exchanging the information between them. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-DU is able to report the Alarm list as per [24] Annex A. + +## 7.22.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. + - Configuration: + +- For details on the test setup refer Annex A - A.5. + +## 7.22.5 Test Procedure + +The following table describes the test procedures to verify SMO sends subscription for alarms to O-RU via O-DU and handles the alarm notification from O-RU via O-DU in hierarchical model. + +**Table 7.22-1: SMO sends subscription for alarms to O-RU via O-DU and handles the alarm notification from O-RU via O-DU in hierarchical model** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------------------------|------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends the create-subscription message to O-RU via O-DU for the selected list of alarms supported. | O-DU ← SMO | Verify SMO sends the create-subscription message for the selected list of alarms to O-RU via O-DU as per Annex A of [24]. | +| 2 | O-RU reports the alarms notification for the SUBSCRIBED event to O-DU. O-DU forwards the reported alarms notification to SMO. | O-DU → SMO | <p>Verify O-RU reports the alarms notification for the SUBSCRIBED event to O-DU and O-DU forwards the SUBSCRIBED event to SMO.</p> <p>Verify the O-RU clear the notification for the SUBSCRIBED event when the SUBSCRIBED event is not met.</p> <p>Verify the O-DU sends clear alarm event to SMO and corresponding stats in SMO is cleared.</p> <p>(Example events: Unit temperature is high, Unit dangerously overheating, etc.).</p> | + +## 7.23 ORAN.WG8.IOT.022: Verify SMO handles any subscribed measurement counters received from O-DU on O1 interface. + +### 7.23.1 Test Purpose + +The purpose of this test case is to verify SMO handles any subscribed measurement counters received from O-DU on O1 interface. + +### 7.23.2 Reference Requirements + +For detailed requirements, refer to the Section 6 in ORAN-WG8.AAD [1]. + +### 7.23.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. + +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per Test case ORAN.WG8.IOT.017. +- The cell is in sync and broadcast message is broadcasted as per ORAN.WG8.IOT.018. +- O-DU and O-RU are exchanging the information between them. +- O-DU obtains the alarm list supported by O-RU using get-alarms-list and store in aggregated data model specified. +- SMO obtains the alarm list supported by O-DU (along with O-RU) using get-alarms-list and store in aggregated data model specified. + +## 7.23.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.5. + +## 7.23.5 Test Procedure + +The following table describes the test procedures to verify SMO sends subscription to O-RU via O-DU for the alarms in hierarchical model. + +**Table 7.23-1: SMO handles any subscribed measurement counters received from O-DU on O1 interface** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------|------------|---------------------------------------------------------------------------------------------------------| +| 1 | SMO sends the SUBSCRIPTION message to O-RU via O-DU. | O-DU ← SMO | Verify SMO sends the SUBSCRITON message to O-RU via O-DU as per the data model mentioned above. | +| 2 | O-DU reports the measurement counters for the SUBSCRIBED counters to SMO using Performance data file. | O-DU → SMO | Verify O-DU reports the measurement counters for the SUBSCRIBED counters to SMO as per Annex A of [24]. | + +## 7.24 ORAN.WG8.IOT.023: Verify O-DU successfully establish E2 Interface with near RT-RIC. + +### 7.24.1 Test Purpose + +The purpose of this test case is to verify O-DU successfully establish E2 Interface with near RT-RIC. + +### 7.24.2 Reference Requirements + +For detailed requirements, refer to the Section 8.2 in ORAN-WG8.AAD [1]. + +### 7.24.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-DU is connected to near RT-RIC. + +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or Ipv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per Test case ORAN.WG8.IOT.018. +- O-DU and O-RU are exchanging the information between them. +- SMO sends Cell Configuration to O-DU the E2 near RT-RIC server IP address as per the data model. + +## 7.24.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test Ues or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A – A.5. + +## 7.24.5 Test Procedure + +The following table describes the test procedures to verify O-DU successfully establish E2 Interface with near RT-RIC. + +**Table 7.24-1: O-DU successfully establish E2 Interface with near RT-RIC** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------|---------------------------|--------------------------------------------------------------------------------------------------| +| 1 | O-DU sends the E2 Setup request to near RT-RIC server. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the E2 Setup request message to near RT-RIC server with all the mandatory les. | +| 2 | near RT-RIC server sends E2 Setup Response to O-DU. | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC sends the E2 setup response to O-DU with all the mandatory les. | + +## 7.25 ORAN.WG8.IOT.024: Verify near RT-RIC server sends subscription request with type as REPORT to O-DU. + +### 7.25.1 Test Purpose + +The purpose of this test case is to verify near RT-RIC server sends subscription request with subscription details as REPORT to O-DU. + +### 7.25.2 Reference Requirements + +For detailed requirements, refer to the Section 8.2 in ORAN-WG8.AAD [1]. + +### 7.25.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-DU is connected to near RT-RIC. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per Test case ORAN.WG8.IOT.018. +- O-DU and O-RU are exchanging the information between them. +- SMO sends Cell Configuration to O-DU the E2 near RT-RIC server IP address as per the data model. + +### 7.25.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. + +- **Testing tools:** Following are required for this test scenario: +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.5. + +## 7.25.5 Test Procedure + +The following table describes the test procedures to verify near RT-RIC server sends subscription request with subscription details as REPORT to O-DU. + +**Table 7.25-1: Near RT-RIC server sends subscription request with IE type as REPORT to O-DU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------------------|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | O-DU sends the E2 Setup request to near RT-RIC server. | O-DU → near RT-RIC | Verify O-DU sends the E2 Setup request message to near RT-RIC server with all the mandatory IEs. | +| 2 | near RT-RIC server sends E2 Setup Response to O-DU. | O-DU ← near RT-RIC | Verify near RT-RIC sends the E2 setup response to O-DU with all the mandatory IEs. | +| 3 | near RT-RIC server sends E2 Subscription Request to O-DU. | O-DU ← near RT-RIC | Verify near RT-RIC server sends E2 Subscription Request to O-DU with IE type as REPORT and the “RIC Actions Admitted List” mentioned in Section 5 of [25].<br>Example: RACH. PreambleDedCell, DRB. UETHpDI, etc. | +| 4 | O-DU sends the E2 Subscription Response to near -RT-RIC server. | O-DU → near RT-RIC | Verify O-DU sends the E2 Subscription Response to near -RT-RIC server. | + +## 7.26 ORAN.WG8.IOT.025: Verify O-DU includes the RIC Actions Not Admitted List in subscription response to near RT-RIC server. + +### 7.26.1 Test Purpose + +The purpose of this test case is to verify O-DU includes the RIC Actions Not Admitted List in subscription response to near RT-RIC server. + +## 7.26.2 Reference Requirements + +For detailed requirements, refer to the Section 8.2 in ORAN-WG8.AAD [1]. + +## 7.26.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-DU is connected to near RT-RIC. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or Ipv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per Test case ORAN.WG8.IOT.018. +- O-DU and O-RU are exchanging the information between them. +- SMO sends Cell Configuration to O-DU the E2 near RT-RIC server IP address as per the data model. + +## 7.26.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test Ues or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A – A.4. + +## 7.26.5 Test Procedure + +The following table describes the test procedures to verify O-DU includes the RIC Actions Not Admitted List in subscription response to near RT-RIC server. + +**Table 7.26-1: O-DU includes the RIC Actions Not Admitted List in subscription response to near RT-RIC server** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|----------------------------------------------------------------------------------------------------------------------------------|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | O-DU sends the E2 Setup request to near -RT-RIC server. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the E2 Setup request message to near RT-RIC server with all the mandatory IEs. | +| 2 | near RT-RIC server sends E2 Setup Response to O-DU. | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC sends the E2 setup response to O-DU with all the mandatory IEs. | +| 3 | near RT-RIC server sends E2 Subscription Request to O-DU. | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC server sends E2 Subscription Request to O-DU with the supported list mentioned in Section 5 of [25].<br>Example: RACH.PreambleDedCell, DRB.UETHpDI, etc. | +| 4 | O-DU sends the E2 Subscription Response to near RT-RIC server with RIC Actions admitted and RIC Actions Not Admitted List items. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the E2 Subscription Response to near-RT-RIC server with “RIC Actions Admitted List” IE filled with O-DU supported list from the SUBSCRIPTION REQUEST and “RIC Actions Not Admitted List” IE filled with O-DU non-supported list. | + +## 7.27 ORAN.WG8.IOT.026: Verify O-DU sends periodic report to the subscribed features to near RT-RIC server. + +### 7.27.1 Test Purpose + +The purpose of this test case is to verify O-DU sends periodic report to the subscribed features to near RT-RIC server. + +### 7.27.2 Reference Requirements + +For detailed requirements, refer to the Section 8.2 in ORAN-WG8.AAD [1]. + +### 7.27.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-DU is connected to near RT-RIC. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per Test case ORAN.WG8.IOT.018. +- O-DU and O-RU are exchanging the information between them. +- SMO sends Cell Configuration to O-DU the E2 near RT-RIC server IP address as per the data model. + +## 7.27.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + +## 7.27.5 Test Procedure + +The following table describes the test procedures to verify O-DU sends periodic report to the subscribed features to near RT-RIC server. + +**Table 7.27-1: SMO handles any subscribed measurement counters received from O-DU on O1 interface** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------------------------------------------------------------------------------------------------------------------|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | O-DU sends the E2 Setup request to near RT-RIC server. | O-DU → near RT-RIC | Verify O-DU sends the E2 Setup request message to near RT-RIC server with all the mandatory IEs. | +| 2 | near RT-RIC server sends E2 Setup Response to O-DU. | O-DU ← near RT-RIC | Verify near RT-RIC sends the E2 setup response to O-DU with all the mandatory IEs. | +| 3 | near RT-RIC server sends E2 Subscription Request to O-DU. | O-DU ← near RT-RIC | Verify near RT-RIC server sends E2 Subscription Request to O-DU with the supported list mentioned in Section 5 of 3GPP Specification [25]. (Example: DRB.UETHpDI). | +| 4 | O-DU sends the E2 Subscription Response to near -RT-RIC server with supported subscription items and not supported items. | O-DU → near RT-RIC | Verify O-DU sends the E2 Subscription Response to near-RT-RIC server with “RIC Actions Admitted List” IE filled with O-DU supported list from the SUBSCRIPTION REQUEST and “RIC Actions Not Admitted List” IE filled with O-DU non-supported list. | +| 5 | O-DU sends the periodic report to the subscribed features to near RT-RIC server through RIC INDICATION message. | O-DU → near RT-RIC | Verify O-DU sends the periodic report to the subscribed features as per the REPORT Service Style mentioned in SUBSCRIPTION REQUEST to near RT-RIC server through RIC INDICATION message. | + +## 7.28 ORAN.WG8.IOT.027: Verify UE attach is successful with the given SSB periodicity and sub-carrier spacing as part of cell configuration structure from SMO to O-DU for FR1 configuration. + +### 7.28.1 Test Purpose + +The purpose of this test case is to verify successful UE attach with given SSB periodicity and sub-carrier spacing. + +### 7.28.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.1 in ORAN-WG8.AAD [1]. + +### 7.28.3 Initial Conditions + +- Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.28.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU +- **Testing tools:** Below tools are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - Use SSB Periodicity as 40ms and sub-carrier spacing as 30Khz (FR1). + - For rest of the MIB and SSB test profiles, refer B.2.1. + +## 7.28.5 Test Procedure + +The following table describes the test procedures for verifying MIB periodicity and sub-carrier spacing. + +**Table 7.28-1: MIB Periodicity and subcarrier spacing** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------------------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <p>ssPbchPower</p> <ul style="list-style-type: none"> <li>subcarrier-spacing (30 KHz)</li> <li>offset-to-carrier</li> <li>SsbPeriod (40 ms)</li> <li>SsbSubcarrierOffset</li> <li>SsbMask[SSB_MAX_SIZE]</li> <li>BeamId</li> <li>betaPss</li> <li>bchPayloadFlag</li> <li>bchPayload</li> <li>dmrsTypeAPos</li> </ul> | +| 2 | Digital beam configuration received from SMO to ODU | <b>SMO → O-DU</b> | <p>Verify that O-DU apply Digital beam weight received from SMO in case of Digital beam forming configuration.</p> <ul style="list-style-type: none"> <li>numDigBeams <ul style="list-style-type: none"> <li>beamIdx = (0-8)</li> </ul> </li> <li>numTXRUs = (0-64) <ul style="list-style-type: none"> <li>digBeamWeightRe</li> <li>digBeamWeightIm</li> </ul> </li> </ul> | +| 3 | Cell bring-up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>Verify O-DU sends beam configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24]. Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 4 | O-DU/O-RU broadcasts SSB configuration as per defined periodicity. | <b>UE ← O-DU/O-CU</b> | <p>Verify that O-DU broadcast SS burst blocks in every configured SSB periodicity(40 ms) in a first half frame within SFN as per 3GPP TS 38.213 sec 4.1.</p> | +| 5 | SSB decoding as per the specified subcarrier spacing | <b>UE ← O-DU/O-CU</b> | <p>Verify that UE able to decode the SSB for the configured sub carrier spacing(30KHz).</p> <p>Verify UE attach is successful with the above mentioned configuration</p> | +| 6 | End to end data validation | <b>O-DU/O-CU → UPF</b> | <p>Verify end to end data is successful</p> | + +## 7.29 ORAN.WG8.IOT.028: Verify UE attach is successful with Transmission periodicity configured to ms2p5 for FR1 configuration. + +### 7.29.1 Test Purpose + +The purpose of this test case is to verify successful UE attach when O-DU is configured with TDD dl-ul-Transmission periodicity as ms2p5 + +### 7.29.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.1.1 in ORAN-WG8.AAD [1]. + +### 7.29.3 Initial Conditions + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.29.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. + +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.4. +- Configure TDD slot format to DDDSU and dl-ul-Transmission periodicity to ms2p5 in SMO +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.29.5 Test Procedure + +The following table below describes the test steps for verifying UE attach with dl-ul-transmission-periodicity of ms2p5. + +**Table 7.29-1: Transmission periodicity configured to ms2p5** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration received from SMO to O-DU | <b>O-DU & SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC.</p> <ul style="list-style-type: none"> <li>• dl-ul-transmission-periodicity (ms2p5)</li> <li>• nr-of-downlink-slots (3)</li> <li>• nr-of-downlink-symbols (10)</li> <li>• nr-of-uplink-slots (1)</li> <li>• nr-of-uplink-symbols (2)</li> </ul> | +| 2 | Digital beam configuration received from SMO to ODU | <b>O-DU & SMO</b> | <p>Verify that O-DU apply Digital beam weight received from SMO in case of Digital beam forming configuration.</p> <ul style="list-style-type: none"> <li>• numDigBeams <ul style="list-style-type: none"> <li>◦ beamIdx = (0-8)</li> </ul> </li> <li>• numTXRUs = (0-64) <ul style="list-style-type: none"> <li>◦ digBeamWeightRe</li> <li>◦ digBeamWeightIm</li> </ul> </li> </ul> | +| 3 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>Verify O-DU sends beam configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | + +| | | | | +|---|---------------------------------------|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------| +| 4 | O-DU sends TDD configuration to O-RU. | <b>O-RU & O-DU</b> | Verify that O-DU sends the dl-ul-transmission-periodicity as ms2p5 and slot format as DDDSU as per 3GPP TS 38.213 sec 11.1. | +| 5 | Attach validation | <b>UE & O-DU/O-CU</b> | verify successful UE attach with ms2p5 dl-ul-transmission-periodicity. | +| 6 | End to end data validation | <b>O-DU/ O-CU & UPF</b> | Verify end to end data is successful | + +## 7.30 ORAN.WG8.IOT.029: Verify UE attach is successful with Transmission periodicity configured to ms5 for FR1 configuration. + +### 7.30.1 Test Purpose + +The purpose of this test case is to verify successful UE attach when O-DU is configured TDD dl-ul-Transmission periodicity as ms5. + +### 7.30.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.1.1 in ORAN-WG8.AAD [1]. + +### 7.30.3 Initial Conditions + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. + +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.30.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +### 7.30.5 Test Procedure + +The following table below describes the test steps for verifying UE attach with dl-ul-transmission-periodicity of ms5 + +**Table 7.30-1: ms5 Transmission periodicity** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration received from SMO to O-DU | <b>O-DU ← SMO</b> | Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC for the TDD slot configuration of DDDDDDDSUU (7D1S2U): <ul style="list-style-type: none"> <li>• dl-ul-transmission-periodicity (ms5)</li> <li>• nr-of-downlink-slots (7)</li> <li>• nr-of-downlink-symbols (10)</li> <li>• nr-of-uplink-slots (2)</li> <li>• nr-of-uplink-symbols (2)</li> </ul> | +| 2 | Digital beam configuration received from SMO to ODU | <b>O-DU ← SMO</b> | Verify that O-DU apply Digital beam weight received from SMO in case of Digital beam forming configuration. <ul style="list-style-type: none"> <li>• numDigBeams <ul style="list-style-type: none"> <li>◦ beamIdx = (0-8)</li> </ul> </li> <li>• numTXRUs = (0-64) <ul style="list-style-type: none"> <li>◦ digBeamWeightRe</li> <li>◦ digBeamWeightIm</li> </ul> </li> </ul> | + +| | | | | +|---|---------------------------------------|--------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>Verify O-DU sends beam configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 4 | O-DU sends TDD configuration to O-RU. | <b>O-RU <math>\leftarrow</math> O-DU</b> | Verify that O-DU sends the dl-ul-transmission-periodicity as ms5 as per 3GPP TS 38.213 sec 11.1. | +| 5 | Attach validation | <b>UE <math>\leftrightarrow</math> O-DU/O-CU</b> | verify successful UE attach with ms5 dl-ul-transmission-periodicity. | +| 6 | End to end data validation | <b>O-DU/ O-CU <math>\rightarrow</math> UPF</b> | Verify end to end data is successful | + +## 7.31 ORAN.WG8.IOT.030: Verify cell bring up is successful with 100Mhz bandwidth configuration received from SMO for FR1 configuration. + +### 7.31.1 Test Purpose + +The purpose of this test case is to verify successful UE attach when O-DU is configured with 100 MHz bandwidth. + +### 7.31.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.1.1 in ORAN-WG8.AAD [1]. + +### 7.31.3 Initial Conditions + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. + +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.31.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +### 7.31.5 Test Procedure + +The following table describes the test steps for cell bring-up verification with 100Mhz bandwidth configuration. + +**Table 7.31-1: 100Mhz bandwidth configuration received from SMO** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|-----------------------------------------------------|-------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <ul style="list-style-type: none"> <li>Carrier Bandwidth (100Mhz)</li> <li>arfcnDL</li> <li>bSChannelBwUL</li> <li>arfcnUL</li> <li>numTxAnt</li> <li>numRxAnt</li> </ul> | +| 2 | Digital beam configuration received from SMO to ODU | <b>O-DU ← SMO</b> | <p>Verify that O-DU apply Digital beam weight received from SMO in case of Digital beam forming configuration.</p> <ul style="list-style-type: none"> <li>numDigBeams <ul style="list-style-type: none"> <li>beamIdx = (0-8)</li> </ul> </li> <li>numTXRUs = (0-64) <ul style="list-style-type: none"> <li>digBeamWeightRe</li> <li>digBeamWeightIm</li> </ul> </li> </ul> | +| 3 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>Verify O-DU sends beam configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 4 | O-DU sends carrier configuration to O-RU. | <b>O-RU ← O-DU</b> | Verify that O-DU sends the Carrier Bandwidth as 100Mhz as per 3GPP TS 38.213 sec 12. | +| 5 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | Verify cell is up and radiating with the above configuration also verify successful UE attach with 100 MHz carrier Bandwidth. | +| 6 | End to end data validation | <b>O-DU/ O-CU → UPF</b> | Verify end to end data is successful | + +## 7.32 ORAN.WG8.IOT.031: Verify DL and UL scheduling information IE's during an end-to-end UDP FDX data transmission for FR1 configuration. + +### 7.32.1 Test Purpose + +The purpose of this test case is to verify end to end uplink and downlink throughput with mandatory IE's exchanged between SMO and O-DU. + +### 7.32.2 Reference Requirements + +For detailed requirements, refer to the section 4.2 in ORAN-WG8.AAD [1]. + +### 7.32.3 Initial Condition + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.32.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.32.5 Test Procedure + +The following table describes the test procedures for bidirectional continuous throughput. + +**Table 7.32-1: DL and UL scheduling information IE's during an end-to-end UDP FDX data transmission** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------|----------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration received from SMO to O-DU | <b>O-DU ← SMO</b> | Verify below precoding related IE's are exchanged between SMO and O-DU during cell bring up <ul style="list-style-type: none"> <li>numLayers</li> <li>numAntPorts</li> </ul> | +| 2 | Cell configuration with beam formatting information received from SMO to O-DU | <b>O-DU ← SMO</b> | Verify below beamforming configuration IE's are exchanged between SMO and O-DU during cell bring-up <ul style="list-style-type: none"> <li>numofBeams</li> <li>numTXRUs</li> <li>beamIndex</li> <li>beamType</li> <li>beamAzimuth</li> <li>beamTilt</li> <li>beamHorizWidth</li> <li>beamVertWidth</li> <li>coverageShape</li> <li>digitalTilt</li> <li>digitalAzimuth</li> </ul> | +| 3 | Digital beam configuration received from SMO to ODU | <b>SMO → O-DU</b> | Verify that O-DU apply Digital beam weight received from SMO in case of Digital beam forming configuration. <ul style="list-style-type: none"> <li>numDigBeams <ul style="list-style-type: none"> <li>beamIdx = (0-8)</li> </ul> </li> <li>numTXRUs = (0-64) <ul style="list-style-type: none"> <li>digBeamWeightRe</li> <li>digBeamWeightIm</li> </ul> </li> </ul> | +| 4 | Cell bring up | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>Verify O-DU sends beam configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.<br><br>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify O-DU sets the administrative state to UNLOCKED state. | +| 5 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | Verify cell is up and radiating with the default configuration. | +| 6 | Trigger UDP Data in Downlink. | <b>UE ← O-CU/<br/>O-DU ← UPF</b> | Verify that O-CU receives DL UDP traffic on the desired Flow on the intendant NG-U connection. | + +| | | | | +|---|--------------------------------------|----------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify O-CU does the mapping of the Flow to the intendant DRB which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic towards O-DU.</p> <p>Verify that O-DU received the UDP traffic without any significant drops in packets.</p> <p>Verify Buffer Occupancy element id transferred from RLC to MAC.</p> <p>Verify DL scheduling information is sent for each TTI and it contains the below parameters<br/>Timing information<br/>Downlink Broadcast Allocation<br/>Time domain allocation<br/>Frequency domain allocation<br/>PDCCH/CORESET configuration<br/>CoresetPoolIndex<br/>DCI information<br/>BWP information</p> <p>Verify gNB enables the tci-presentInDCI IE and includes the IE tci-StatePDCCHToAddList IE, as per section 11.2.4.3.8 in ORAN-WG8.AAD [1]</p> <p>Verify PDSCH scheduling is happening as per dynamic TCI states configured in DCI message.</p> <p>Verify DL beam-forming configuration between O-DU and O-RU from FAPI logs as per sec 3.4.2 in FAPI specification [12]</p> <p>Verify coresetPoolIndex-r16 is correctly included within PDCCH/CORESET configuration from UE logs.</p> <p>Verify successful scheduling of downlink data when CoresetPoolIndex IE is included within PDCCH/CORESET configuration.</p> | +| 7 | Trigger UDP Data transfer in Uplink. | <b>UE → O-DU/<br/>O-CU → UPF</b> | <p>Verify that O-DU receives UL UDP traffic on the desired DRB which is intendant and forwards to O-CU using the GTP-U user plane connection.</p> <p>O-CU do the mapping of the DRB to Flow mapping which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic on the NG-U tunnel towards UPF.</p> <p>Verify that UPF received the UDP traffic without any significant drops in packets.</p> <p>Verify UL scheduling information is sent for each TTI and it contains parameters below<br/>BeamPUSCHInfo<br/>numPRGs<br/>prgSize<br/>digBFInterfaces<br/>prgInfo<br/>PMIdx<br/>BeamIdx</p> <p>Verify UL beam-forming configuration between O-DU and O-RU from FAPI logs as per sec 3.4.3 in FAPI specification [12]</p> | + +| | | | | +|---|----------------------------|-----------------------------|--------------------------------------| +| 8 | End to end data validation | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify end to end data is successful | +|---|----------------------------|-----------------------------|--------------------------------------| + +## 7.33 ORAN.WG8.IOT.032: Verify cell bring up is successful with 64 beams and 64 antenna ports configuration received from SMO to O-DU for FR2 configuration. + +### 7.33.1 Test Purpose + +The purpose of this test case is to verify cell bring up is successful with 64 beams and 64 antenna ports configuration received from SMO to O-DU + +### 7.33.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.1 in ORAN-WG8.AAD [1]. + +### 7.33.3 Initial Condition + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.33.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU + +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. + - Configuration: +- For details on the test setup refer Annex A - A.4. +- For rest of the MIB and SSB test profiles, refer B.2.1 +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +### 7.33.5 Test Procedure + +The following table describes the test procedures to verify the successful cell activation when 64 beams and 64 antenna ports configuration received from SMO for non co-located(remote) O-RU and O-DU. + +**Table 7.33-1: 64 beams and 64 antenna ports configuration received from SMO to O-DU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|--------------------------------------------------------------|-------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <ul style="list-style-type: none"> <li>ssb-PositionsInBurst <ul style="list-style-type: none"> <li>groupPresence = 11111111</li> <li>inOneGroup = 11111111</li> </ul> </li> <li>ssb-periodicityServingCell</li> <li>subCarrierSpacingCommon</li> <li>ssb-SubcarrierOffset (0-11)</li> <li>numTxAnt</li> <li>numRxAnt</li> <li>numofBeams (64)</li> <li>numTXRUs (64)</li> <li>beamIndex (64)</li> <li>numAntPorts (64)</li> </ul> | +| 2 | Cell bring-up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration received from SMO.</p> <p>Verify O-DU sends beam configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 3 | O-DU/O-RU broadcast 64 SSB beams as per defined periodicity. | <b>UE ← O-DU/O-CU</b> | <p>Verify the O-RU transmit all the 64 beams with the periodicity of 40ms.</p> <p>Verify UE selects the strongest SSB beam from 64 beams broadcasted and send RACH request with PRACH config index corresponding to beam selected.</p> | +| 4 | Attach validation | <b>UE ← O-DU/O-CU</b> | <p>Verify that UE able to attach successfully with above mentioned configuration</p> | +| 5 | End to end data validation | <b>O-DU/ O-CU → UPF</b> | <p>Verify end to end data is successful.</p> | + +## 7.34 ORAN.WG8.IOT.033: Verify cell bring up is successful with 8 beams and 64 antenna ports configuration received from SMO to O-DU for FR1 configuration. + +### 7.34.1 Test Purpose + +The purpose of this test case is to verify cell bring up is successful with 8 beams and 64 antenna ports configuration received from SMO to O-DU + +### 7.34.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.1 in ORAN-WG8.AAD [1]. + +### 7.34.3 Initial Condition + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.34.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.34.5 Test Procedure + +The following table describes the test procedures to verify the successful cell activation when 8 beams and 64 antenna ports configuration received from SMO for non-co-located(remote) O-RU and O-DU. + +**Table 7.34-1: 8 beams and 64 antenna ports configuration received from SMO to O-DU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------------|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <ul style="list-style-type: none"> <li>ssb-PositionsInBurst <ul style="list-style-type: none"> <li>inOneGroup =11111111</li> </ul> </li> <li>ssb-periodicityServingCell</li> <li>subCarrierSpacingCommon</li> <li>ssb-SubcarrierOffset (0-15)</li> <li>numTxAnt</li> <li>numRxAnt</li> <li>numofBeams (8)</li> <li>numTXRUs (64)</li> <li>beamIndex (8)</li> <li>numAntPorts (64)</li> </ul> | +| 2 | Digital beam configuration received from SMO to ODU | <b>O-DU ← SMO</b> | <p>Verify that O-DU apply Digital beam weight received from SMO in case of Digital beam forming configuration.</p> <ul style="list-style-type: none"> <li>numDigBeams <ul style="list-style-type: none"> <li>beamIdx = (0-64)</li> </ul> </li> <li>numTXRUs = (0-64) <ul style="list-style-type: none"> <li>digBeamWeightRe</li> <li>digBeamWeightIm</li> </ul> </li> </ul> | +| 3 | Cell bring-up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>Verify O-DU sends beam configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 4 | O-DU/O-RU broadcast SSB beams as per defined periodicity. | <b>UE ← O-DU/O-CU</b> | <p>Verify the O-RU transmit all the 8 beams with a periodicity of 20ms.</p> <p>Verify UE selects the strongest SSB beam from 8 beams broadcasted and sends RACH request with PRACH config index corresponding to beam selected.</p> | +| 5 | Attach validation | <b>UE ← O-DU/O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration | +| 6 | End to end data validation | <b>O-DU/O-CU → UPF</b> | Verify end to end data is successful. | + +## 7.35 ORAN.WG8.IOT.034: Verify cell bring up is successful and UE attach when the O-DU is configured with 32 punctured SSB beams for FR2 configuration. + +### 7.35.1 Test Purpose + +The purpose of this test case is to verify cell bring up is successful and UE attach when the O-DU is configured with 32 punctured SSB beams. + +### 7.35.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.1 in ORAN-WG8.AAD [1]. + +### 7.35.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.35.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** Following are required for this test scenario: +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. + +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.4. +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.35.5 Test Procedure + +The following table describes the test procedures to verify the successful cell activation when 32 beams and 64 antenna ports configuration received from SMO for non co-located(remote) O-RU and O-DU. + +**Table 7.35-1: O-DU is configured with 32 punctured SSB beams** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|------------------------------------------------------------|-------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <ul style="list-style-type: none"> <li>ssb-PositionsInBurst <ul style="list-style-type: none"> <li>groupPresence = 11111111</li> <li>inOneGroup = 10101010</li> </ul> </li> <li>ssb-periodicityServingCell</li> <li>subCarrierSpacingCommon</li> <li>ssb-SubcarrierOffset (0-11)</li> <li>numTxAnt</li> <li>numRxAnt</li> <li>numofBeams (32)</li> <li>numTXRUs</li> <li>beamIndex (32)</li> <li>numAntPorts (64)</li> </ul> | +| 2 | Cell bring-up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>Verify O-DU sends beam configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 3 | O-DU/O-RU broadcasts SSB beams as per defined periodicity. | <b>UE ← O-DU/O-CU</b> | <p>Verify the O-RU transmit all the 32 beams with a periodicity of 40 ms.</p> <p>Verify UE selects the strongest SSB beam from 32 beams broadcasted and sends RACH request with PRACH config index corresponding to beam selected.</p> | +| 4 | Attach validation | <b>UE ← O-DU/O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration | +| 5 | End to end data validation | <b>O-DU/ O-CU → UPF</b> | Verify end to end data is successful. | + +## 7.36 ORAN.WG8.IOT.035: Verify cell bring up is successful when the parameter Occasion And CB-Preambles per SSB is configured to 1 by SMO for FR1 configuration. + +### 7.36.1 Test Purpose + +The purpose of this test case is to verify cell bring up is successful when the parameter occasion and CB-preambles per SSB is configured to 1 by SMO. + +### 7.36.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.1 in ORAN-WG8.AAD [1]. + +### 7.36.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.36.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.36.5 Test Procedure + +The following table describes the test procedures to verify the successful cell activation when parameter Occasion And CB-Preambles Per SSB is configured to 1 by SMO for non co-located(remote) O-RU and O-DU. + +**Table 7.36-1: Occasion And CB-Preambles per SSB is configured to 1 by SMO** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|-----------------------------------------------------------|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration received from SMO to O-DU. | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC and also containing all the mandatory IEs mentioned in section 11.2.1.1 NR cell configuration, Table 11-6 ,11-7 of ORAN.WG8.AAD [1]</p> <ul style="list-style-type: none"> <li>• ssb-PositionsInBurst <ul style="list-style-type: none"> <li>◦ inOneGroup =11111111</li> </ul> </li> <li>• ssb-periodicityServingCell</li> <li>• subCarrierSpacingCommon</li> <li>• ssb-SubcarrierOffset (0-15)</li> <li>• numTxAnt</li> <li>• numRxAnt</li> <li>• numofBeams (8)</li> <li>• numTXRUs (64)</li> <li>• beamIndex (0-8)</li> <li>• numAntPorts (64)</li> <li>• msg1-FDM = one</li> <li>• ssb-perRACH-OccasionAndCB-PreamblesPerSSB = one</li> </ul> | +| 2 | Digital beam configuration received from SMO to ODU. | <b>SMO → O-DU</b> | <p>Verify that O-DU apply Digital beam weight received from SMO in case of Digital beam forming configuration.</p> <ul style="list-style-type: none"> <li>• numDigBeams <ul style="list-style-type: none"> <li>◦ beamIdx = (0-8)</li> </ul> </li> <li>• numTXRUs = (0-64) <ul style="list-style-type: none"> <li>◦ digBeamWeightRe</li> <li>◦ digBeamWeightIm</li> </ul> </li> </ul> | +| 3 | Cell bring-up. | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>Verify O-DU sends beam configuration and mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 4 | O-DU/O-RU broadcast SSB beams as per defined periodicity. | <b>UE ← O-DU/O-CU</b> | <p>Verify the O-RU transmit all the 8 beams with a periodicity of 20ms.</p> <p>Verify UE selects the strongest SSB beam from 8 beams broadcasted and sends RACH request with PRACH config index corresponding to beam selected.</p> | +| 5 | Attach validation | <b>UE ← O-DU/O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration. | +| 6 | End to end data validation | <b>O-DU/O-CU → UPF</b> | Verify end to end data is successful. | + +## 7.37 ORAN.WG8.IOT.036: Verify the successful cell activation when slice specific configuration containing list of slices in the TA per PLMN is sent towards MAC/SCH on the O1 interface. + +### 7.37.1 Test Purpose + +The purpose of this test case is to verify the successful cell activation when slice specific configuration containing list of slices in the TA per PLMN is sent towards MAC/SCH on the O1 interface. + +### 7.37.2 Reference Requirements + +For detailed requirements, refer to the section 11.3 in ORAN-WG8.AAD [1]. + +### 7.37.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected.[22] +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.37.4 Test Setup and Configuration + +- **DUTs:** single O-DU, O-CU and single SMO. +- **Testing tools:** Following are required for this test scenario: +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. + +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.5. + +## 7.37.5 Test Procedure + +The following table describes the test procedures to verify cell activation when slice specific configuration containing list of slices in the TA per PLMN is sent towards MAC/SCH on the O1 interface + +**Table 7.37-1: Cell activation when slice specific configuration received from SMO for O-DU on O1 interface** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|------------------------------------------------|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends Cell Configuration to O-DU. | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC and also containing all the mandatory IEs mentioned in section 11.2.1.1, Table 11-2 of [1]</p> <ul style="list-style-type: none"> <li>• PLMN Information List <ul style="list-style-type: none"> <li>○ PLMNid = Valid configured value</li> <li>○ S-NSSAIIist</li> <li>○ 24930</li> <li>○ 24931</li> <li>○ 24932</li> </ul> </li> </ul> <p>Verify O-DU sends mandatory cell configuration to O-RU and ensures that O-RU carrier-state is changed to ACTIVE</p> | +| 2 | SMO sends Slice Configuration Request to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC and also containing all the mandatory IEs mentioned in section 11.2.4.2.3, Table 11-22 of [1]</p> <ul style="list-style-type: none"> <li>• S-NSSAI = 24930 <ul style="list-style-type: none"> <li>○ RRMPolicyRatio = PRB</li> <li>○ rRMPolicyMaxRatio = 50</li> <li>○ rRMPolicyMinRatio = 30</li> <li>○ rRMPolicyDedicatedRatio = 20</li> </ul> </li> </ul> | +| 3 | O-DU sends Slice Configuration Response to SMO | <b>O-DU → SMO</b> | <p>Verify O-DU sends response after verifying S-NSSAI should be within slice range and part of slice support list.</p> <p>Verify O-DU sends the slice configuration response to SMO as per below IEs mentioned in section 11.2.4.3.4 in Section 11.2 of [1]</p> <ul style="list-style-type: none"> <li>• Slice Index = 24930</li> <li>• Response = OK</li> </ul> <p>Slice configuration and prioritization is followed according to the O-RAN specification.</p> | + +| | | | | +|----|-------------------------------------------------------------------------------------|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 4 | O-DU sends sync-state information and set the operational state in SMO. | <b>O-DU → SMO</b> | <p>Verify O-DU shall send the sync-state as LOCKED to SMO. Verify O-DU set the operational state to ENABLED state.</p> <p>O-DU also ensures that sync-state from O-RU is set to LOCKED.</p> | +| 5 | SMO shall set the administrative state of O-DU. | <b>O-DU ← SMO</b> | Verify O-DU shall set the administrative state to UNLOCKED state. | +| 6 | O-DU sends an F1 SETUP REQUEST to establish connectivity between the O-DU and O-CU. | <b>O-DU → O-CU</b> | <p>Verify O-DU sends F1 SETUP REQUEST message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-CU-CP (Control Unit).</p> <p>Verify F1 SETUP REQUEST message should contain "TAI Slice Support List" IE for each served PLMNs within "Served Cell Information" as mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-CU-CP (Control Unit).</p> | +| 7 | O-CU sends NGAP Setup Request to AMF. | <b>O-CU → AMF</b> | <p>Verify the NGAP Setup Request should contain all the mandatory IEs mentioned in the section 9.2.6.1 of 3GPP Specification [20].</p> <p>Verify NGAP Setup Request message should contain IE "TAI Slice Support List" as mentioned in the section 9.2.6.1 of 3GPP Specification [20].</p> | +| 8 | O-CU receives NGAP Setup Response from AMF. | <b>O-CU ← AMF</b> | <p>Verify AMF sends NGAP Setup Response message containing all the mandatory IEs mentioned in 9.2.6.1 of 3GPP Specification [20].</p> <p>Verify NGAP Setup Response message should contain "Slice Support List" within "PLMN Support List" as mentioned in 9.2.6.2 of 3GPP Specification [20].</p> | +| 9 | O-DU receives F1 SETUP RESPONSE from O-CU. | <b>O-DU ← O-CU</b> | Verify O-CU sends F1 SETUP RESPONSE message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-DU. | +| 10 | Cell Bring-up is initiated at O-CU. | <b>O-DU ← O-CU</b> | <p>O-CU sends the F1AP gNB-CU configuration update to O-DU.</p> <p>F1AP gNB-CU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>O-CU should add the cell information according to IE Served-Cells-To-Add-List.</p> | +| 11 | O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU. | <b>O-DU → O-CU</b> | <p>Verify O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU.</p> <p>F1AP gNB-CU configuration update Ack message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 12 | Activate the cell from the O-DU. | <b>O-DU → O-CU</b> | <p>O-DU sends the F1AP gNB-DU configuration update to O-CU.</p> <p>F1AP gNB-DU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> <p>F1AP gNB-DU configuration update message should contain "TAI Slice Support List" IE for each served PLMNs within "Served Cell Information" as</p> | + +| | | | | +|----|-------------------------------------------------------------------------|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].<br><br>O-DU should activate the cell information according to the service-state IE. | +| 13 | O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU. | <b>O-DU ← O-CU</b> | Verify O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU.<br><br>F1AP gNB-DU configuration update Ack message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19]. | +| 14 | Verify the status of the cell. | <b>O-RU ← O-DU</b> | Verify O-DU sends cell status as ACTIVE to O-RU.<br><br>Verify SMO shows O-CU and O-DU operational and newly added cell is up and RF state of O-RU is active. | + +## 7.38 ORAN.WG8.IOT.037: Verify UE Registration and PDU session establishment procedure with an allowed S-NSSAI. + +### 7.38.1 Test Purpose + +The purpose of this test case is to verify UE Registration and PDU session establishment procedure with an allowed S-NSSAI. + +### 7.38.2 Reference Requirements + +For detailed requirements, refer to the section 11.3 in ORAN-WG8.AAD [1]. + +### 7.38.3 Initial Conditions + +Following are the preconditions for this test. + +- The Cell Setup is successful with using configuration received from SMO as per test case ORAN.WG8.IOT.036. +- F1AP connection is successful between O-CU and O-DU. +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- The UE has a valid Default Configured S-NSSAI. + +### 7.38.4 Test Setup and Configuration + +- **DUTs:** single O-DU, O-CU and single SMO. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. + +- Protocol Analyzer is used to record and observe F1AP, NGAP, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.5. +- For details on the MIB and SSB test profiles, see B.2. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.38.5 Test Procedure + +The following table below describes the test steps for Registration procedure with a slice + +**Table 7.38-1: Slice Registration & PDU Session establishment** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------------------------|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | The UE sends RRCSetupRequest with random ue-identity and establishment cause (refer to the section 5.3.3 in 3GPP 38.331 [8]). | <b>UE → O-DU/<br/>O-CU</b> | Verify that O-DU receives the RRC setup Request message from the UE and sends Initial UL RRC message to O-CU with RRC setup request message in RRC container.<br><br>Verify all the mandatory IEs of Initial UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19]. | +| 2 | UE receives RRCsetup message for SRB1 creation. | <b>UE ← O-DU/<br/>O-CU</b> | Verify that O-CU sends DL RRC message transfer to O-DU with RRC setup message in the RRC container to establish SRB1.<br><br>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].<br><br>Verify that O-DU sends RRC setup message to UE.<br><br>Verify all the mandatory IEs of RRC setup as per section 6.2.2 in 3GPP Specification. [8]. | +| 3 | UE sends RRC setup complete message over SRB1 with Registration Request as NAS payload. | <b>UE → O-DU/<br/>O-CU</b> | Verify that O-DU receives the RRC setup complete message with registration request as NAS payload from UE and sends UL RRC message transfer to O-CU with RRC setup complete and Registration Request message in RRC container.<br><br>Verify RRCSetupComplete contains s-NSSAI-List for AMF selection.<br><br>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].<br><br>Verify that O-CU sends Initial UE Message to AMF with NAS payload as Registration Request.<br><br>Verify that Registration Request message should contain Requested NSSAI IE & Network Slicing Indication IE as per section 8.2.6.1 of 3GPP Specifications. [21]<br><br>Verify all the mandatory IEs of Initial UE message as per section 9.2.5.1 of 3GPP Specification [20]. | +| 4 | UE receives NAS Authentication Request message from AMF with authentication parameters | <b>UE ← O-DU/<br/>O-CU</b> | Verify that O-CU receives DL NAS Transport message with Authentication request as NAS payload. | + +| | | | | +|---|------------------------------------------------------------------------------------------------|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | required for successfully authenticating the network. | | <p>Verify that O-CU sends DL RRC Message Transfer to O-DU with NAS Authentication Request in the RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Authentication request message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> | +| 5 | UE sends NAS Authentication response message after successfully authenticating the network. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Authentication Response message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Authentication response in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Authentication Response as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 6 | UE receives NAS Security mode command message for integrity protection and ciphering. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives DL NAS Transport message with security mode command as NAS payload.</p> <p>Verify that O-CU sends DL RRC Message Transfer to O-DU with NAS Security mode command in the RRC container</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Security mode command message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> | +| 7 | UE sends NAS Security mode complete message. This message is integrity protected and ciphered. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Security mode complete message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Security mode complete message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Security mode complete as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 8 | UE receives AS security mode command message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives Initial context setup request or DL NAS Transport from AMF with Registration accept as NAS payload.</p> <p>Verify all the mandatory IEs as per the section 9.2.2.1 or 9.2.5.2 in 3GPP Specification [20].</p> <p>Verify Initial Context Setup request mandatorily contains Allowed NSSAI and an S-NSSAI optionally for each PDU Session Resource Setup Request List.</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU with AS security mode command message in RRC container.</p> | + +| | | | | +|----|---------------------------------------------|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify the O-DU sends SecurityModeCommand to UE which contains AS integrity and Ciphering Algorithms supported by O-CU.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> | +| 9 | UE sends AS Security mode complete message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify in response of previous step, the O-DU receives SecurityModeComplete from UE.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains AS security mode complete in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | +| 10 | UE receives UE capability Enquiry message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives the UE radio capability check request from AMF to check the compatibility between UE radio capabilities and network configuration.</p> <p>O-CU can optionally request for the UE capability enquiry to the UE.</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU which contains UE capability enquiry in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends UE capability enquiry to UE to check the UE capabilities.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> | +| 11 | UE sends UE capability information message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify in response of previous step, the O-DU receives UE capability information from UE.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains UE capability information in the RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UE Radio Capability Info Indication message to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.13.1 in 3GPP Specification [20].</p> | +| 12 | UE receives Registration Accept message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU sends DL RRC message transfer to O-DU which contains Registration Accept in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Registration accept message.</p> | + +| | | | | +|----|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify that Registration Accept message should contain Allowed NSSAI IE & Configured NSSAI IE as per section 8.2.7.1 of 3GPP Specifications [21].</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> | +| 13 | UE sends Registration complete message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Registration complete message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Registration complete message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Initial context setup response to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.2.2 in 3GPP Specification [20].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Registration complete as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 14 | The UE sends PDU session Establishment Request with one of the Allowed S-NSSAI received in Registration Accept (refer to the section 8.3.1 in 3GPP Specification [21]). | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UL information transfer message which contains PDU session establishment request as NAS message.</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains PDU session establishment request in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Uplink NAS transport with NAS PDU as PDU Session Establishment Request to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.5.3 in 3GPP Specification [20].</p> <p>Verify PDU session establishment request should contain S-NSSAI as per section 8.2.10 of 3GPP Specifications [21].</p> | + +| | | | | +|----|-------------------------------------------------------------------------------|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 15 | UE receives RRC reconfiguration and PDU session establishment accept message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives PDU Session Resource Setup Request from AMF with NAS-PDU as PDU session establishment accept.</p> <p>Verify all the mandatory IEs as per section 9.2.1.1 in 3GPP Specification [20].</p> <p>Verify that O-CU sends UE context setup request to O-DU for establishing the DRB.</p> <p>Verify that UE context setup should contain S-NSSAI within DRB Information as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify all the mandatory IEs of UE context setup request as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends UE context setup response to O-CU after successfully establishing the DRB.</p> <p>Verify all the mandatory IEs of UE context setup response as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU with RRC reconfiguration in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends RRC reconfiguration message to UE which contains PDU session establishment accept as NAS payload.</p> | +| 16 | UE sends RRC reconfiguration complete. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives RRC reconfiguration complete from UE.</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU with RRC reconfiguration complete in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends PDU Session Resource Setup Response to AMF over NG interface.</p> <p>Verify all the mandatory IEs as per section 9.2.1.2 in 3GPP Specification [20].</p> | + +## 7.39 ORAN.WG8.IOT.038: Verify downlink data prioritization/scheduling on basis of slice differentiation in-case of each UE with single PDU session per slice. + +### 7.39.1 Test Purpose + +The purpose of this test case is to verify downlink data prioritization/scheduling on basis of slice differentiation as specified by RRM policy to meet the specific Slice Level agreement in-case of each UE with single PDU session per slice. + +### 7.39.2 Reference Requirements + +For detailed requirements, refer to the section 11.3 in ORAN-WG8.AAD [1]. + +### 7.39.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell Setup is successful with the configuration received from SMO as per test case ORAN.WG8.IOT.036. +- F1AP connection is successful between O-DU and O-CU. +- The UE has decoded MIB and SIB1. +- 2 UEs RACH procedure is successful. +- 2 UEs RRC setup is successful. +- 2 UEs Registration is successful with Allowed S-NSSAIs. +- UE 0 PDU session establishment procedure with Slice #1 is successful. +- UE 1 PDU session establishment procedure with Slice #2 is successful. +- RRM policy successfully configured on Slice #1 +- RRMPolicyRatio = PRB +- rRMPolicyMaxRatio = 90 +- rRMPolicyMinRatio = 30 +- rRMPolicyDedicatedRatio = 30 +- RRM policy successfully configured on Slice #2 +- RRMPolicyRatio = PRB +- rRMPolicyMaxRatio = 50 +- rRMPolicyMinRatio = 40 +- rRMPolicyDedicatedRatio = 20 +- Slice #2 have higher slice priority than Slice #1. (Implementation specific) + +### 7.39.4 Test Setup and Configuration + +- **DUTs:** single O-DU, O-CU and single SMO. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, NAS, HTTP2, PFCP protocol content. +- Configuration: + +- For details on the test setup refer Annex A - A.5. +- For details on the MIB and SSB test profiles, see B.2. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +### 7.39.5 Test Procedure + +The following table describes the test procedures for downlink data prioritization/scheduling on basis of slice differentiation. + +**Table 7.39-1: Slice level downlink data prioritization** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------|-----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Trigger UDP Data of transfer in Downlink on the 2 UEs with any traffic generator tool or IPERF application. | <b>O-CU/ O-DU<br/>← UPF</b> | <p>Verify that O-CU receives DL UDP traffic on the desired Flow on the intended NG-U connection.</p> <p>O-CU do the mapping of the Flow to the intended DRB which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic towards O-DU.</p> <p>Verify that O-DU applies RRM policies on PRB against each slice.</p> <p>Verify 30% of PRB is utilized for Slice #1 and resource isolation for Slice #1 is achieved.</p> <p>Verify 40% of PRB is utilized for Slice #2 and resource isolation for Slice #2 is achieved.</p> <p>Verify the UE can also achieve max throughput using shared and prioritized resources once dedicated resources are utilized.</p> <p>Verify the scheduler considers slice priority and schedule the UE on Slice #2 to achieve expected throughput and doesn't follow fair allocation in-case of different slice priorities.</p> <p>Slice configuration and prioritization is followed according to the O-RAN specification.</p> | +| 2 | Measure throughput on UE. | <b>UE ← O-DU/<br/>O-CU</b> | Verify that O-DU received the UDP traffic without any significant drops in packets. | + +## 7.40 ORAN.WG8.IOT.039: Verify downlink data scheduling on basis of QoS flow prioritization when two PDU sessions have equal slice priority. + +### 7.40.1 Test Purpose + +The purpose of this test case is to verify downlink data scheduling on basis of QoS flow prioritization when two PDU sessions have equal slice priority. + +## 7.40.2 Reference Requirements + +For detailed requirements, refer to the section 11.3 in ORAN-WG8.AAD [1]. + +## 7.40.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell Setup is successful with using configuration received from SMO as per test case ORAN.WG8.IOT.036. +- F1AP connection is successful between O-DU and O-CU. +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup is successful. +- Registration is successful with Allowed S-NSSAIs. +- PDU session establishment procedure with Slice #1 & Slice #2 is successful. +- RRM policy successfully configured as per test case ORAN.WG8.IOT.038. +- Slice #1 and Slice #2 have equal priority. (Implementation specific) + +## 7.40.4 Test Setup and Configuration + +- **DUTs:** single O-DU, O-CU and single SMO. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.5. + - For details on the MIB and SSB test profiles, see B.2. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.40.5 Test Procedure + +The following table describes the test procedure to verify downlink data scheduling on basis of QoS flow prioritization when two PDU sessions have equal slice priority. + +**Table 7.40-1: Downlink data scheduling on basis of equal slice priority** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------------|-----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Trigger UDP Data of transfer in Downlink on the 2 QoS Flows with any traffic generator tool or IPERF application. | <b>O-CU/ O-DU<br/>← UPF</b> | <p>Verify that O-CU receives DL UDP traffic on the desired Flow on the intended NG-U connection.</p> <p>O-CU do the mapping of the Flow to the intended DRB which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic towards O-DU.</p> <p>Verify that O-DU applies RRM policies on PRB against each slice.</p> <p>Verify 30% of PRB is utilized for Slice #1 and resource isolation for Slice #1 is achieved.</p> <p>Verify 40% of PRB is utilized for Slice #2 and resource isolation for Slice #2 is achieved.</p> <p>Verify the UE can also achieve max throughput using shared and prioritized resources once dedicated resources are utilized.</p> <p>Verify as both the slices have equal priority, the scheduler considers QoS level & 5QI level priority associated with the QFI while scheduling the UE.</p> <p>Slice configuration and prioritization is followed according to the O-RAN specification.</p> | +| 2 | Measure throughput on UE. | <b>UE ← O-DU/<br/>O-CU</b> | Verify that O-DU received the UDP traffic without any significant drops in packets. | + +## 7.41 ORAN.WG8.IOT.040: Verify key performance metrics with the sub-counters at S-NSSAI level. + +### 7.41.1 Test Purpose + +The purpose of this test case is to verify key performance metrics with the sub-counters at S-NSSAI level. + +### 7.41.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.7.1 in ORAN-WG8.AAD [1]. + +### 7.41.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell Setup is successful with using configuration received from SMO as per test case ORAN.WG8.IOT.036. +- F1AP connection is successful between O-DU and O-CU. +- The UE has decoded MIB and SIB1. +- 2 UEs RACH procedure is successful. +- 2 UEs RRC setup is successful. +- 2 UEs Registration is successful with Allowed S-NSSAIs. + +- UE 0 PDU session establishment procedure with Slice #1 is successful. +- UE 1 PDU session establishment procedure with Slice #2 is successful. +- RRM policy successfully configured as per test case ORAN.WG8.IOT.038. + +## 7.41.4 Test Setup and Configuration + +- **DUTs:** single O-DU, O-CU and single SMO. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.5. + - For details on the MIB and SSB test profiles, see B.2. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.41.5 Test Procedure + +The following table describes the test procedures for performance metrics with the sub-counters at S-NSSAI level. + +**Table 7.41-1: Performance Counters at S-NSSAI level** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------|-----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Trigger UDP Data of transfer in Downlink on the 2 UEs with any traffic generator tool or IPERF application. | <b>O-CU/ O-DU<br/>← UPF</b> | <p>Verify that O-CU receives DL UDP traffic on the desired Flow on the intended NG-U connection.</p> <p>O-CU do the mapping of the Flow to the intended DRB which will be done by the SDAP protocol resides in the O-CU and then forward the UDP traffic towards O-DU.</p> <p>Verify that O-DU applies RRM policies on PRB against each slice.</p> <p>Verify 30% of PRB is utilized for Slice #1 and resource isolation for Slice #1 is achieved.</p> <p>Verify 40% of PRB is utilized for Slice #2 and resource isolation for Slice #2 is achieved.</p> <p>Slice configuration and prioritization is followed according to the O-RAN specification</p> | + +| | | | | +|---|------------------------------------------------------------------------------|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2 | Measure throughput on UE. | <b>UE ← O-DU/<br/>O-CU</b> | Verify that O-DU received the UDP traffic without any significant drops in packets. | +| 3 | O-DU collects the performance counters at slice level and reports it to SMO. | <b>O-DU → SMO</b> | Verify the following counters are successfully accumulated per slice and sent towards SMO as mentioned in Annexure A of [19]:<br><br>OR.RRU.PrbTotDIDist.BinX.SNSSAI<br><br>OR.AveDlCellThroughput.SNSSAI | + +## 7.42 ORAN.WG8.IOT.041: Verify successful slice re-configuration when RRM Policy is updated on the O1 interface. + +### 7.42.1 Test Purpose + +The purpose of this test case is to verify successful slice re-configuration when RRM Policy is updated on the O1 interface for a specific S-NSSAI. + +### 7.42.2 Reference Requirements + +For detailed requirements, refer to the section 11.3 in ORAN-WG8.AAD [1]. + +### 7.42.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell Setup is successful with using configuration received from SMO as per test case ORAN.WG8.IOT.036. +- F1AP connection is successful between O-DU and O-CU. +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup is successful. +- Registration is successful with Allowed S-NSSAIs. +- RRM policy successfully configured as per test case ORAN.WG8.IOT.038. + +### 7.42.4 Test Setup and Configuration + +- **DUTs:** single O-DU, O-CU and single SMO. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. + +- Protocol Analyzer is used to record and observe F1AP, NGAP, NAS, HTTP2, PCF protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.5. +- For details on the MIB and SSB test profiles, see B.2. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.42.5 Test Procedure + +The following table describes the test procedures for successful slice re-configuration when RRM Policy is updated on the O1 interface for a specific S-NSSAI. + +**Table 7.42-1: Slice Reconfiguration on O1 interface** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Attach validation | <b>O-DU</b> | Verify that UE is able to attach successfully with cell and slice configuration received from SMO | +| 2 | End to end data validation | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify end to end data is successful. | +| 3 | SMO sends Slice Reconfiguration Request to O-DU | <b>O-DU ←<br/>SMO</b> | <p>Verify SMO reconfigures RRMPolicyRatio attributes when slice SLA is not achieved with the configured dedicated resources.</p> <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC to reconfigure/update RRMPolicyRatio attributes containing all the mandatory IEs mentioned in section 11.2.4.2.3, Table 11-22 of [1]</p> <ul style="list-style-type: none"> <li>• S-NSSAI = 24930 <ul style="list-style-type: none"> <li>◦ RRMPolicyRatio = PRB</li> <li>◦ rRMPolicyMaxRatio = 90</li> <li>◦ rRMPolicyMinRatio = 50</li> <li>◦ rRMPolicyDedicatedRatio = 20</li> </ul> </li> </ul> | +| 4 | O-DU sends Slice Reconfiguration Response to SMO | <b>O-DU →<br/>SMO</b> | <p>Verify O-DU sends the Slice Reconfiguration Response to SMO as per below IEs supported in Section 11.2 of [1]:</p> <ul style="list-style-type: none"> <li>• Slice Index = 24930</li> <li>• Response = OK</li> </ul> | +| 5 | End to end data validation | <b>UE ↔ O-DU/O-CU</b> | <p>Verify end to end data is successful.</p> <p>Verify 30% of PRB can now be utilized for Slice #1 as reconfigured by the SMO.</p> <p>Slice configuration and prioritization is followed according to the O-RAN specification</p> | + +## 7.43 ORAN.WG8.IOT.042: Verify slice reconfiguration failure in-case of incorrect S-NSSAI is updated on the O1 interface. + +### 7.43.1 Test Purpose + +The purpose of this test case is to verify slice reconfiguration failure in-case of incorrect S-NSSAI is updated on the O1 interface. + +### 7.43.2 Reference Requirements + +For detailed requirements, refer to the section 11.3 in ORAN-WG8.AAD [1]. + +### 7.43.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell Setup is successful with using configuration received from SMO as per test case ORAN.WG8.IOT.036. +- F1AP connection is successful between O-DU and O-CU. +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- RRC setup is successful. +- Registration is successful with Allowed S-NSSAIs. +- RRM policy successfully configured as per test case ORAN.WG8.IOT.038. + +### 7.43.4 Test Setup and Configuration + +- **DUTs:** single O-DU, O-CU and single SMO. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.5. + - For details on the MIB and SSB test profiles, see B.2. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.43.5 Test Procedure + +The following table describes the test procedures for slice reconfiguration failure in-case of incorrect S-NSSAI is updated on the O1 interface. + +**Table 7.43-1: Slice Reconfiguration on O1 interface** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Attach validation | <b>O-DU</b> | Verify that UE able to attach successfully with cell and slice configuration received from SMO | +| 2 | End to end data validation | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify end to end data is successful. | +| 3 | SMO sends Slice Reconfiguration Request to O-DU | <b>O-DU ←<br/>SMO</b> | Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC to reconfigure/update RRMPolicyRatio attributes containing all the mandatory IEs mentioned in section 11.2.4.2.3, Table 11-22 of [1] <ul style="list-style-type: none"> <li>• S-NSSAI = 17000000 (S-NSSAI invalid) <ul style="list-style-type: none"> <li>○ RMPolicyRatio = PRB</li> <li>○ rRMPolicyMaxRatio = 50</li> <li>○ rRMPolicyMinRatio = 30</li> <li>○ rRMPolicyDedicatedRatio = 30</li> </ul> </li> </ul> | +| 4 | O-DU sends Slice Reconfiguration Response to SMO | <b>O-DU →<br/>SMO</b> | Verify O-DU sends the Slice Reconfiguration Response to SMO as per below IEs supported in Section 11.2 of [1] <ul style="list-style-type: none"> <li>• Slice Index = 24934</li> <li>• Response = NOK</li> <li>• Error Cause = slice not supported in cell</li> </ul> | +| 5 | Verify the status of cell. | <b>O-DU/O-CU</b> | Verify SMO shows O-CU and O-DU operational and cell is up and RF state of O-RU is active. | +| 6 | End to end data validation | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify end to end data is successful after slice reconfiguration failure.<br><br>Slice configuration and prioritization is followed according to the O-RAN specification | + +## 7.44 ORAN.WG8.IOT.043: Verify cell activation when O-DU is receiving synchronization from external timing source and sync-state is locked. + +### 7.44.1 Test Purpose + +The purpose of this test case is to verify the successful cell activation when O-DU is receiving synchronization from external timing source and O-DU sync-state is locked. + +### 7.44.2 Reference Requirements + +For detailed requirements, refer to the section 7.11 in ORAN-WG8.AAD [1]. + +### 7.44.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU.[22] +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using O-RAN Fronthaul Transport Synchronization profile (LLS-C3) defined by O-RAN WG4 specification [26]. + +### 7.44.4 Test Setup and Configuration + +- **DUTs:** single O-DU, O-CU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. + - Local or remote external time source connected to the O-DU. +- **Configuration:** + - For details on the test setup refer Annex A - A.7. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + +- For details on the RACH test profiles, see B.6. + +## 7.44.5 Test Procedure + +The following table describes the test procedures to verify the successful cell activation when receiving synchronization from external timing source. + +**Table 7.44-1: Cell activation when receiving synchronization from external timing source** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends O-DU synchronization parameters to be provisioned to the O-DU. | <b>O-DU ← SMO</b> | Verify the following parameters are provisioned on O-DU from o-ran-synchronization.yang as given in [27]: <ul style="list-style-type: none"> <li>• sync-source = GNSS</li> <li>• enable = TRUE</li> <li>• satellite-constellation-list = GPS</li> </ul> | +| 2 | O-RU sends sync-status information to O-DU | <b>O-RU → O-DU</b> | Verify O-RU is able to achieve time synchronization with GPS.<br><br>Verify O-RU shall send the sync-status as LOCKED to O-DU. | +| 3 | O-DU sends sync-state information and set the operational state in SMO. | <b>O-DU → SMO</b> | Verify O-DU shall send the sync-state as LOCKED to SMO. Verify O-DU set the operational state to ENABLED state. | +| 4 | SMO shall set the administrative state of O-DU. | <b>O-DU ← SMO</b> | Verify O-DU shall set the administrative state to UNLOCKED state. | +| 5 | O-DU sends an F1 SETUP REQUEST to establish connectivity between the O-DU and O-CU. | <b>O-DU → O-CU</b> | Verify O-DU sends F1 SETUP REQUEST message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-CU-CP (Control Unit). | +| 6 | O-CU sends NGAP Setup Request to AMF. | <b>O-CU → AMF</b> | Verify the NGAP Setup Request should contain all the mandatory IEs mentioned in the section 9.2.6.1 of 3GPP Specification [20]. | +| 7 | O-CU receives NGAP Setup Response from AMF. | <b>O-CU ← AMF</b> | Verify AMF sends NGAP Setup Response message containing all the mandatory IEs mentioned in 9.2.6.1 of 3GPP Specification [20]. | +| 8 | O-DU receives F1 SETUP RESPONSE from O-CU. | <b>O-DU ← O-CU</b> | Verify O-CU sends F1 SETUP RESPONSE message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-DU. | +| 9 | Cell Bring-up is initiated at O-CU. | <b>O-DU ← O-CU</b> | O-CU sends the F1AP gNB-CU configuration update to O-DU.<br><br>F1AP gNB-CU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].<br><br>O-CU should add the cell information according to IE Served-Cells-To-Add-List. | +| 10 | O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU. | <b>O-DU → O-CU</b> | Verify O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU.<br><br>F1AP gNB-CU configuration update Ack message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19]. | + +| | | | | +|----|-------------------------------------------------------------------------|-------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 11 | Activate the cell from the O-DU. | <b>O-DU → O-CU</b> | <p>O-DU sends the F1AP gNB-DU configuration update to O-CU.</p> <p>F1AP gNB-DU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> <p>O-DU should activate the cell information according to the service-state IE.</p> | +| 12 | O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU. | <b>O-DU ← O-CU</b> | <p>Verify O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU.</p> <p>F1AP gNB-DU configuration update Ack message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> | +| 13 | Verify the status of the cell. | <b>O-DU/O-CU</b> | <p>Verify SMO shows O-CU and O-DU operational and newly added cell is up and RF state of O-RU is ACTIVE.</p> <p>Verify O-RU sync-state is set to LOCKED state and available for CU-plane communication,</p> | +| 14 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | Verify that UE able to attach successfully. | +| 15 | End to end data validation | <b>O-DU/ O-CU ↔ UPF</b> | Verify end to end data is successful. | + +## 7.45 ORAN.WG8.IOT.044: Verify cell activation when O-DU is receiving synchronization from external timing source and sync-state is not locked. + +### 7.45.1 Test Purpose + +The purpose of this test case is to verify gNB-CU Configuration Update procedure when O-DU is receiving synchronization from external timing source and O-DU sync-state is not locked. + +### 7.45.2 Reference Requirements + +For detailed requirements, refer to the section 7.11 in ORAN-WG8.AAD [1]. + +### 7.45.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. + +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using O-RAN Fronthaul Transport Synchronization profile (LLS-C3) defined by O-RAN WG4 specification [26]. + +## 7.45.4 Test Setup and Configuration + +- **DUTs:** single O-DU, O-CU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. + - Local or remote external time source connected to the O-DU. +- Configuration: + - For details on the test setup refer Annex A - A.7. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.45.5 Test Procedure + +The following table describes the test procedures to verify gNB-DU Configuration Update procedure when O-DU is receiving synchronization from external timing source and O-DU sync-state is not locked. + +**Table 7.45-1: Cell activation failure when failed to receive synchronization from external timing source** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|-----------------------------------------------------------------------------------|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO provisions O-DU synchronization parameters have been provisioned to the O-DU. | <b>O-DU ← SMO</b> | Verify the following parameters are provisioned on O-DU from o-ran-synchronization.yang as given in [27]: <ul style="list-style-type: none"> <li>• sync-source = GNSS</li> <li>• enable = TRUE</li> <li>• satellite-constellation-list = GPS</li> </ul> | +| 2 | Time Synchronization at O-RU is not achieved | <b>O-RU → O-DU</b> | Verify O-RU shall send the sync-status as FREERUN to O-DU. | +| 3 | O-DU sends sync-state information and set the operational state in SMO. | <b>O-DU → SMO</b> | Verify O-DU shall send the sync-state as FREERUN to SMO. Verify O-DU set the operational state to ENABLED state. | +| 4 | SMO shall set the administrative state of O-DU. | <b>O-DU ← SMO</b> | Verify O-DU shall set the administrative state to UNLOCKED state. | +| 5 | O-DU doesn't initiate Cell Bring-up procedure. | <b>O-DU/O-CU</b> | Verify O-DU doesn't initiate F1 setup request procedure. | + +## 7.46 ORAN.WG8.IOT.045: Verify cell activation when O-DU is receiving synchronization from external timing source and sync-state transits from locked to holdover and freerun. + +### 7.46.1 Test Purpose + +The purpose of this test case is to verify gNB-DU Configuration Update procedure when O-DU is receiving synchronization from external timing source and O-DU sync-state transits from locked to holdover to freerun. + +### 7.46.2 Reference Requirements + +For detailed requirements, refer to the section 7.11 in ORAN-WG8.AAD [1]. + +### 7.46.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to 5GC through NG interface and O-CU is operational. + +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using O-RAN Fronthaul Transport Synchronization profile (LLS-C3) defined by O-RAN WG4 specification [26]. + +## 7.46.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. + - Local or remote external time source connected to the O-DU. +- Configuration: + - For details on the test setup refer Annex A - A.7. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.46.5 Test Procedure + +The following table describes the test procedures to verify cell activation when O-DU is receiving synchronization from external timing source and sync-state transits from locked to holdover and freerun. + +**Table 7.46-1: Cell activation failure when fail to receive synchronization from external timing source and sync-state transits from locked to holdover and freerun** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------------------------------------|-------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO provisions O-DU synchronization parameters have been provisioned to the O-DU. | <b>O-DU ← SMO</b> | Verify the following parameters are provisioned on O-DU from o-ran-synchronization.yang as given in [27]: <ul style="list-style-type: none"> <li>• sync-source = GNSS</li> <li>• enable = TRUE</li> <li>• satellite-constellation-list = GPS</li> </ul> | + +| | | | | +|----|-------------------------------------------------------------------------------------|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2 | O-RU sends sync-status information to O-DU | <b>O-RU → O-DU</b> | Verify O-RU is able to achieve time synchronization with GPS.<br><br>Verify O-RU shall send the sync-status as LOCKED to O-DU. | +| 3 | O-DU sends sync-state information and set the operational state in SMO. | <b>O-DU → SMO</b> | Verify O-DU shall send the sync-state as LOCKED to SMO. Verify O-DU set the operational state to ENABLED state. | +| 4 | SMO shall set the administrative state of O-DU. | <b>O-DU ← SMO</b> | Verify O-DU shall set the administrative state to UNLOCKED state. | +| 5 | O-DU sends an F1 SETUP REQUEST to establish connectivity between the O-DU and O-CU. | <b>O-DU → O-CU</b> | Verify O-DU sends F1 SETUP REQUEST message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-CU-CP (Control Unit). | +| 6 | O-CU sends NGAP Setup Request to AMF. | <b>O-CU → AMF</b> | Verify the NGAP Setup Request should contain all the mandatory IEs mentioned in the section 9.2.6.1 of 3GPP Specification [20]. | +| 7 | O-CU receives NGAP Setup Response from AMF. | <b>O-CU ← AMF</b> | Verify AMF sends NGAP Setup Response message containing all the mandatory IEs mentioned in 9.2.6.1 of 3GPP Specification [20]. | +| 8 | O-DU receives F1 SETUP RESPONSE from O-CU. | <b>O-DU ← O-CU</b> | Verify O-CU sends F1 SETUP RESPONSE message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-DU. | +| 9 | Cell Bring-up is initiated at O-CU. | <b>O-DU ← O-CU</b> | O-CU sends the F1AP gNB-CU configuration update to O-DU.<br><br>F1AP gNB-CU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].<br><br>O-CU should add the cell information according to IE Served-Cells-To-Add-List. | +| 10 | O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU. | <b>O-DU → O-CU</b> | Verify O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU.<br><br>F1AP gNB-CU configuration update Ack message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19]. | +| 11 | Activate the cell from the O-DU. | <b>O-DU → O-CU</b> | O-DU sends the F1AP gNB-DU configuration update to O-CU.<br><br>F1AP gNB-DU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].<br><br>O-DU should activate the cell information according to the service-state IE. | +| 12 | O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU. | <b>O-DU ← O-CU</b> | Verify O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU.<br><br>F1AP gNB-DU configuration update Ack message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19]. | +| 13 | Verify the status of the cell. | <b>O-DU/O-CU</b> | Verify SMO shows O-CU and O-DU operational and newly added cell is up and RF state of O-RU is ACTIVE. | + +| | | | | +|----|--------------------------------------------------------------------------------------|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | Verify O-RU sync-state is set to LOCKED state and available for CU-plane communication, | +| 14 | O-DU sends sync-state information to SMO when external time synchronization is lost. | <b>O-DU → SMO</b> | Verify O-DU shall send the sync-state as HOLDOVER to SMO. | +| 15 | Verify the status of the cell. | <b>O-DU/O-CU</b> | Verify SMO shows O-CU and O-DU operational and newly added cell is up and RF state of O-RU is ACTIVE.<br><br>Verify O-RU sync-state is set to LOCKED state and available for CU-plane communication, | +| 16 | Holdover mode expires at O-DU. | <b>O-DU</b> | Verify O-DU shall send the sync-state as FREERUN to SMO. | +| 17 | O-DU sends the gNB-DU CONFIGURATION UPDATE message to O-CU | <b>O-DU → O-CU</b> | Verify O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU.<br><br>Verify that as O-DU sync state was not locked, it shall not activate any cells from Cells to be Activated List Item IE.<br><br>Verify that O-DU shall report back to O-CU Cells failed to be activated list IE.<br><br>F1AP gNB-CU configuration update Ack message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].<br><br>O-DU sends the F1AP gNB-DU configuration update to O-CU.<br><br>F1AP gNB-DU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].<br><br>O-DU should send the cell information according to the service-state IE i.e. Out-Of-Service. | +| 18 | O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU. | <b>O-DU ← O-CU</b> | Verify O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU.<br><br>F1AP gNB-DU configuration update Ack message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19]. | + +## 7.47 ORAN.WG8.IOT.046: Verify cell activation when O-DU successfully receive synchronization from secondary source when sync fails with the primary source. + +### 7.47.1 Test Purpose + +The purpose of this test case is to verify the successful cell activation when O-DU successfully receive synchronization from secondary source when sync fails with the primary source. + +## 7.47.2 Reference Requirements + +For detailed requirements, refer to the section 7.11 in ORAN-WG8.AAD [1]. + +## 7.47.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- O-DU is physically installed. It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using O-RAN Fronthaul Transport Synchronization profile (LLS-C3) defined by O-RAN WG4 specification [26]. + +## 7.47.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single SMO. +- **Testing tools:** Following are required for this test scenario: + - Test UEs or UE emulator which can support NR. + - 5G-NR O-RU or O-RU emulator. + - 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + - Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. + - Local or remote external time source connected to the O-DU. + - Configuration: + - For details on the test setup refer Annex A - A.7. + - For details on the MIB and SSB test profiles, see B.2.1. + +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.47.5 Test Procedure + +The following table describes the test procedures to verify cell activation when O-DU is receiving synchronization from secondary timing source when synchronization with primary source fails. + +**Table 7.47-1: Cell activation when receiving synchronization from secondary timing source** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------------------------------------------------|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO provisions O-DU synchronization parameters have been provisioned to the O-DU. | <b>O-DU ← SMO</b> | Verify the following parameters are provisioned on O-DU from o-ran-synchronization.yang as given in [27]: <ul style="list-style-type: none"> <li>• sync-config</li> <li>• sync-priority-config <ul style="list-style-type: none"> <li>• sync-source = GNSS</li> <li>• sync-source = PTP</li> </ul> </li> <li>• enable = TRUE</li> <li>• satellite-constellation-list = GPS</li> </ul> | +| 2 | Time Synchronization with GNSS fails and O-DU retries the time Sync with secondary source PTP | <b>O-DU / O-RU</b> | Verify O-RU is able to achieve time synchronization with PTP.<br><br>Verify O-DU is able to achieve time synchronization with PTP. | +| 3 | O-RU sends sync-status information to O-DU | <b>O-RU → O-DU</b> | Verify O-RU shall send the sync-status as LOCKED to O-DU. | +| 4 | O-DU sends sync-state information and set the operational state in SMO. | <b>O-DU → SMO</b> | Verify O-DU shall send the sync-state as LOCKED to SMO. Verify O-DU set the operational state to ENABLED state. | +| 5 | SMO shall set the administrative state of O-DU. | <b>O-DU ← SMO</b> | Verify O-DU shall set the administrative state to UNLOCKED state. | +| 6 | O-DU sends an F1 SETUP REQUEST to establish connectivity between the O-DU and O-CU. | <b>O-DU → O-CU</b> | Verify O-DU sends F1 SETUP REQUEST message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-CU-CP (Control Unit). | +| 7 | O-CU sends NGAP Setup Request to AMF. | <b>O-CU → AMF</b> | Verify the NGAP Setup Request should contain all the mandatory IEs mentioned in the section 9.2.6.1 of 3GPP Specification [20]. | +| 8 | O-CU receives NGAP Setup Response from AMF. | <b>O-CU ← AMF</b> | Verify AMF sends NGAP Setup Response message containing all the mandatory IEs mentioned in 9.2.6.1 of 3GPP Specification [20]. | +| 9 | O-DU receives F1 SETUP RESPONSE from O-CU. | <b>O-DU ← O-CU</b> | Verify O-CU sends F1 SETUP RESPONSE message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the O-DU. | +| 10 | Cell Bring-up is initiated at O-CU. | <b>O-DU ← O-CU</b> | O-CU sends the F1AP gNB-CU configuration update to O-DU. | + +| | | | | +|----|-------------------------------------------------------------------------|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>F1AP gNB-CU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>O-CU should add the cell information according to IE Served-Cells-To-Add-List.</p> | +| 11 | O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU. | <b>O-DU → O-CU</b> | <p>Verify O-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to O-CU.</p> <p>F1AP gNB-CU configuration update Ack message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 12 | Activate the cell from the O-DU. | <b>O-DU → O-CU</b> | <p>O-DU sends the F1AP gNB-DU configuration update to O-CU.</p> <p>F1AP gNB-DU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> <p>O-DU should activate the cell information according to the service-state IE.</p> | +| 13 | O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU. | <b>O-DU ← O-CU</b> | <p>Verify O-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to O-DU.</p> <p>F1AP gNB-DU configuration update Ack message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> | +| 14 | Verify the status of the cell. | <b>O-DU/O-CU</b> | <p>Verify SMO shows O-CU and O-DU operational and newly added cell is up and RF state of O-RU is ACTIVE.</p> <p>Verify O-RU sync-state is set to LOCKED state and available for CU-plane communication,</p> | +| 15 | Attach validation | <b>UE ← O-DU/O-CU</b> | Verify that UE able to attach successfully. | +| 16 | End to end data validation | <b>O-DU/O-CU → UPF</b> | Verify end to end data is successful. | + +## 7.48 ORAN.WG8.IOT.047: Verify O-CU and O-DU provisions HO configuration sent over O1 interface by SMO for inter-O-DU handover within an O-CU + +### 7.48.1 Test Purpose + +The purpose of this test case is to verify O-CU and O-DU provisions HO configuration sent over O1 interface by SMO for inter-O-DU handover within an O-CU + +### 7.48.2 Reference Requirement + +For detailed requirements, refer to the section 10.2.2 in ORAN-WG8.AAD [1]. + +## 7.48.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU's. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.48.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU's, O-CU and O-RU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.6. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.48.5 Test Procedure + +The following table describes the test procedures to verify O-CU and O-DU provisions HO configuration sent over O1 interface by SMO for inter-O-DU handover within an O-CU. + +**Table 7.48-1: Verify O-CU and O-DU provisions HO configuration sent over O1 interface by SMO for inter-O-DU handover within an O-CU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------|-----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends cell configuration to both O-DU and O-CU | <b>O-DU ← SMO,<br/>O-CU ← SMO</b> | Verify SMO sends below mandatory configuration configured for handover towards O-CU<br>cellIndividualOffset <ul style="list-style-type: none"> <li>• rsrpOffsetSSB</li> <li>• rsrqOffsetSSB</li> <li>• sinrOffsetSSB</li> <li>• rsrpOffsetCSI-RS</li> <li>• rsrqOffsetCSI-RS</li> <li>• sinrOffsetCSI-RS</li> <li>• isHOAllowed</li> <li>• nRFreqRelationRef</li> <li>• adjacentNRCellRef</li> </ul> | +| 2 | Verify both O-CU and O-DU provisions HO configuration sent over O1 interface by SMO | <b>O-DU ← SMO,<br/>O-CU ← SMO</b> | Verify provisioning is successful in both O-CU and O-DU | +| 3 | Verify both O-CU and O-DU comes and cell bring up successful | <b>O-DU/O-RU/O-CU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>Verify O-DU sends mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.<br><br>Verify O-DU sets the administrative state to UNLOCKED state. | + +## 7.49 ORAN.WG8.IOT.048: Verify successful Intra frequency measurement based inter-O-DU handover within an O-CU + +### 7.49.1 Test Purpose + +The purpose of this test case is to verify successful intra frequency measurement based inter-O-DU handover within an O-CU + +### 7.49.2 Reference Requirement + +For detailed requirements, refer to the section 10.2.2 in ORAN-WG8.AAD [1]. + +### 7.49.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. + +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU's. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.49.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU's, O-CU and O-RU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.6. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.49.5 Test Procedure + +The following table describes the test procedures to verify successful intra frequency measurement based inter-O-DU handover within an O-CU. + +**Table 7.49-1: Verify successful intra frequency measurement based inter-O-DU handover within an O-CU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends cell configuration to O-DU. | <b>O-DU ← SMO</b> | Verify SMO sends below mandatory IEs configured for inter O-DU HO within an O-CU towards O-CU<br>cellIndividualOffset <ul style="list-style-type: none"> <li>• rsrpOffsetSSB</li> <li>• rsrqOffsetSSB</li> <li>• sinrOffsetSSB</li> <li>• rsrpOffsetCSI-RS</li> <li>• rsrqOffsetCSI-RS</li> <li>• sinrOffsetCSI-RS</li> </ul> isHOAllowed<br>nRFreqRelationRef<br>adjacentNRCellRef | +| 2 | Verify cell bring up successful for both O-DU | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>Verify each O-DU sends mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.<br><br>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify O-DU sets the administrative state to UNLOCKED state. | +| 3 | Trigger registration procedure for UE with source O-DU | <b>UE ↔ O-DU/O-CU</b> | Verify registration procedure is successful. O-CU allocates MeasConfig containing following in RRC Reconfiguration <ul style="list-style-type: none"> <li>. MeasObjectToAddModList</li> <li>. ReportConfigToAddModList</li> <li>. MeasIdToAddModList</li> </ul> | +| 4 | Trigger UDP/TCP data transfer | <b>UE ↔ O-DU/O-CU</b> | Verify end to end data transfer is successful | +| 5 | Move UE from source cell towards target cell so that UE triggers Measurement Report when criteria for defined event within ReportConfig met | <b>UE → O-DU</b> | Verify UE reports configured event on defined criteria within MeasConfig containing following <ul style="list-style-type: none"> <li>. MeasId</li> <li>. measResultNeighCells <ul style="list-style-type: none"> <li>-MeasResultListNR</li> <li>-physCellId</li> <li>-measResult</li> </ul> </li> </ul> | +| 6 | Verify source O-DU forwards received measurement report towards O-CU in UL RRC Message transfer | <b>O-DU → O-CU</b> | Verify source O-DU includes received measurement report within RRC Container. O-CU validates received measurement report of neighbor cell and if neighbor cell satisfies defined criteria for triggering HO at O-CU then HO towards target O-DU gets triggered. | +| 7 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU ← O-CU</b> | Verify O-CU have included IE GNB-DU Configuration Query set to True | +| 8 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify source O-DU includes IE DU To CU RRC Information, Full Configuration and Full Configuration value set to True | +| 9 | Verify O-CU sends UE Context Setup Request towards target O-DU | <b>O-DU ← O-CU</b> | Verify O-CU includes following in UE Context Setup Request <ul style="list-style-type: none"> <li>. List of DRB to be setup list</li> <li>. Handover Preparation Information within CUtoDURRCInformation</li> </ul> | + +| | | | | +|-----|-----------------------------------------------------------------------------------------------------------|-----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 10 | Verify target O-DU sends UE Context Setup Response towards O-CU | <b>O-DU → O-CU</b> | Verify target O-DU includes following in UE Context Setup Response <ul style="list-style-type: none"> <li>. List of DRB successfully admitted</li> <li>. DUtoCURRInformation</li> </ul> | +| 11 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU ← O-CU</b> | Verify O-CU includes following in UE Context Modification Request <ul style="list-style-type: none"> <li>. RRC-Container for sending RRC Reconfiguration towards UE</li> <li>. Transmission Action Indicator set to Stop</li> </ul> | +| 12 | Verify source O-DU forwards received RRC Reconfiguration towards UE | <b>UE → O-DU</b> | Verify UE received following in RRC Reconfiguration <ul style="list-style-type: none"> <li>. ReconfigurationWithSync <ul style="list-style-type: none"> <li>- spCellConfigCommon</li> <li>- newUE-Identity</li> <li>- t304</li> <li>- rach-ConfigDedicated</li> </ul> </li> </ul> | +| 13 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify O-CU receives UE Context Modification Response successfully | +| 14 | Verify UE triggers CFRA RACH based on configuration received in RRC Reconfiguration towards target O-DU | <b>UE → O-DU</b> | Verify CFRA RACH process is successful within defined timer t304 towards target O-DU | +| 15 | Verify UE sends RRC Reconfiguration Complete towards target O-DU | <b>UE → O-DU</b> | Verify target O-DU receives RRC Reconfiguration Complete successfully | +| 16 | Verify target O-DU forwards received RRC Reconfiguration Complete in UL RRC Message Transfer towards O-CU | <b>UE → O-DU</b> | Verify O-CU receives UL RRC Message transfer over F1 interface successfully from target O-DU | +| 17 | Verify data transfer towards UE successful through target O-DU | <b>UE ↔ O-DU/O-CU</b> | Verify end to end data transfer is successful | +| 18 | Verify O-CU sends UE Context Release Command towards source O-DU | <b>O-DU ← O-CU</b> | Verify UE Context Release command contains cause as below <p>Cause: radioNetwork<br/>radioNetwork: normal-release</p> | +| s19 | Verify source O-DU sends UE Context Release Complete towards O-CU | <b>O-DU → O-CU</b> | Verify O-CU receives UE Context Release Command successfully from source O-DU | + +## 7.50 ORAN.WG8.IOT.049: Verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having single QFI established + +### 7.50.1 Test Purpose + +The purpose of this test case is to verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having single QFI established. + +## 7.50.2 Reference Requirement + +For detailed requirements, refer to the section 10.2.2 in ORAN-WG8.AAD [1]. + +## 7.50.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU's. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.50.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU's, O-CU and O-RU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.6. +- For details on the MIB and SSB test profiles, see B.2.1. + +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.50.5 Test Procedure + +The following table describes the test procedures to verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having single QFI established. + +**Table 7.50-1: Verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having single QFI established** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends cell configuration to O-DU. | <b>O-DU ← SMO</b> | Verify SMO sends below mandatory IEs configured for inter O-DU HO within an O-CU towards O-CU cellIndividualOffset <ul style="list-style-type: none"> <li>• rsrpOffsetSSB</li> <li>• rsrqOffsetSSB</li> <li>• sinrOffsetSSB</li> <li>• rsrpOffsetCSI-RS</li> <li>• rsrqOffsetCSI-RS</li> <li>• sinrOffsetCSI-RS</li> </ul> isHOAllowed<br>nRFreqRelationRef<br>adjacentNRCellRef | +| 2 | Verify cell bring up successful for both O-DU | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>Verify each O-DU sends mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.<br><br>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify O-DU sets the administrative state to UNLOCKED state. | +| 3 | Trigger registration procedure for UE with source O-DU and establish multiple PDU session with single QFI | <b>UE ↔ O-DU/O-CU</b> | Verify registration procedure is successful. O-CU allocates MeasConfig containing following in RRC Reconfiguration <ul style="list-style-type: none"> <li>. MeasObjectToAddModList</li> <li>. ReportConfigToAddModList</li> <li>. MeasIdToAddModList</li> </ul> Verify multi PDU sessions are established as per requirement for GBR, Non-GBR and Delay critical GBR bearer | +| 4 | Trigger UDP/TCP data transfer | <b>UE ↔ O-DU/O-CU</b> | Verify end to end data transfer is successful across all PDU session | +| 5 | Move UE from source cell towards target cell so that UE triggers Measurement Report when criteria for defined event within ReportConfig met | <b>UE → O-DU</b> | Verify UE reports configured event on defined criteria within MeasConfig containing following <ul style="list-style-type: none"> <li>. MeasId</li> <li>. measResultNeighCells <ul style="list-style-type: none"> <li>-MeasResultListNR</li> <li>-physCellId</li> <li>-measResult</li> </ul> </li> </ul> | + +| | | | | +|----|--------------------------------------------------------------------------------------------------------------|-----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 6 | Verify source O-DU forwards received Measurement Report towards O-CU in UL RRC Message transfer | <b>O-DU → O-CU</b> | Verify source O-DU includes received measurement report within RRC Container. O-CU validates received measurement report of neighbor cell and if neighbor cell satisfies defined criteria for triggering HO at O-CU then HO towards target O-DU gets triggered. | +| 7 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU ← O-CU</b> | Verify O-CU have included IE GNB-DU Configuration Query set to True | +| 8 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify source O-DU includes IE DU To CU RRC Information, Full Configuration and Full Configuration value set to True | +| 9 | Verify O-CU sends UE Context Setup Request towards target O-DU | <b>O-DU ← O-CU</b> | Verify O-CU includes following in UE Context Setup Request <ul style="list-style-type: none"> <li>. List of DRB to be setup list</li> <li>. Handover Preparation Information within CUtoDURRCInformation</li> </ul> | +| 10 | Verify target O-DU sends UE Context Setup Response towards O-CU | <b>O-DU → O-CU</b> | Verify target O-DU includes following in UE Context Setup Response <ul style="list-style-type: none"> <li>. List of DRB successfully admitted</li> <li>. DUtoCURRCInformation</li> </ul> | +| 11 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU ← O-CU</b> | Verify O-CU includes following in UE Context Modification Request <ul style="list-style-type: none"> <li>. RRC-Container for sending RRC Reconfiguration towards UE</li> <li>. Transmission Action Indicator set to Stop</li> </ul> | +| 12 | Verify source O-DU forwards received RRC Reconfiguration towards UE | <b>UE → O-DU</b> | Verify UE received following in RRC Reconfiguration <ul style="list-style-type: none"> <li>. ReconfigurationWithSync <ul style="list-style-type: none"> <li>- spCellConfigCommon</li> <li>- newUE-Identity</li> <li>- t304</li> <li>- rach-ConfigDedicated</li> </ul> </li> </ul> | +| 13 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify O-CU receives UE Context Modification Response successfully | +| 14 | Verify UE triggers CFRA RACH based on configuration received in RRC Reconfiguration RACH towards target O-DU | <b>UE → O-DU</b> | Verify CFRA RACH process is successful within defined timer t304 towards target O-DU | +| 15 | Verify UE sends RRC Reconfiguration Complete towards target O-DU | <b>UE → O-DU</b> | Verify target O-DU receives RRC Reconfiguration Complete successfully | +| 16 | Verify target O-DU forwards received RRC Reconfiguration Complete in UL RRC Message Transfer towards O-CU | <b>UE → O-DU</b> | Verify O-CU receives UL RRC Message transfer over F1 interface successfully from target O-DU | +| 17 | Verify data transfer towards UE successful through target O-DU | <b>UE ↔ O-DU/O-CU</b> | Verify end to end data transfer is successful across all PDU session in target O-DU | +| 18 | Verify O-CU sends UE Context Release Command towards source O-DU | <b>O-DU ← O-CU</b> | Verify UE Context Release command contains cause as below <p>Cause: radioNetwork<br/>radioNetwork: normal-release</p> | +| 19 | Verify source O-DU sends UE Context Release Complete towards O-CU | <b>O-DU → O-CU</b> | Verify O-CU receives UE Context Release Command successfully from source O-DU | + +## 7.51 ORAN.WG8.IOT.050: Verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having multiple QFI established where few PDU sessions are admitted at target DU + +### 7.51.1 Test Purpose + +The purpose of this test case is to verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having multiple QFI established where few PDU sessions are admitted at target DU. + +### 7.51.2 Reference Requirement + +For detailed requirements, refer to the section 10.2.2 in ORAN-WG8.AAD [1]. + +### 7.51.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU's. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.51.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU's, O-CU and O-RU +- **Testing tools:** are required for this test scenario. + +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.6. +- For details on the MIB and SSB test profiles, see B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.51.5 Test Procedure + +The following table describes the test procedures to verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having multiple QFI established where few PDU sessions are admitted at target DU. + +**Table 7.51-1: Verify successful inter-O-DU handover within an O-CU with multiple PDU session (GBR, Non-GBR, Delay critical GBR bearer) and each PDU session having multiple QFI established where few PDU sessions are admitted at target DU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends cell configuration to O-DU. | <b>O-DU ← SMO</b> | Verify SMO sends below mandatory IEs configured for inter O-DU HO within an O-CU towards O-CU cellIndividualOffset <ul style="list-style-type: none"> <li>• rsrpOffsetSSB</li> <li>• rsrqOffsetSSB</li> <li>• sinrOffsetSSB</li> <li>• rsrpOffsetCSI-RS</li> <li>• rsrqOffsetCSI-RS</li> <li>• sinrOffsetCSI-RS</li> </ul> isHOAllowed<br>nRFreqRelationRef<br>adjacentNRCellRef | +| 2 | Verify cell bring up successful for both O-DU | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>Verify each O-DU sends mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.<br><br>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify O-DU sets the administrative state to UNLOCKED state. | + +| | | | | +|----|---------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3 | Trigger registration procedure for UE with source O-DU and establish multiple PDU session with multiple QFI | <b>UE ↔ O-DU/O-CU</b> | Verify registration procedure is successful.<br>O-CU allocates MeasConfig containing following in RRC Reconfiguration <ul style="list-style-type: none"> <li>. MeasObjectToAddModList</li> <li>. ReportConfigToAddModList</li> <li>. MeasIdToAddModList</li> </ul> Verify multi PDU sessions are established as per requirement for GBR, Non-GBR and Delay critical GBR bearer | +| 4 | Trigger UDP/TCP data transfer | <b>UE ↔ O-DU/O-CU</b> | Verify end to end data transfer is successful across all PDU session | +| 5 | Move UE from source cell towards target cell so that UE triggers Measurement Report when criteria for defined event within ReportConfig met | <b>UE → O-DU</b> | Verify UE reports configured event on defined criteria within MeasConfig containing following <ul style="list-style-type: none"> <li>. MeasId</li> <li>. measResultNeighCells <ul style="list-style-type: none"> <li>-MeasResultListNR</li> <li>-physCellId</li> <li>-measResult</li> </ul> </li> </ul> | +| 6 | Verify O-DU forwards received Measurement Report towards O-CU in UL RRC Message transfer | <b>O-DU → O-CU</b> | Verify source O-DU includes received measurement report within RRC Container. O-CU validates received measurement report of neighbor cell and if neighbor cell satisfies defined criteria for triggering HO at O-CU then HO towards target O-DU gets triggered. | +| 7 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU ← O-CU</b> | Verify O-CU have included IE GNB-DU Configuration Query set to True | +| 8 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify source O-DU includes IE DU To CU RRC Information, Full Configuration and Full Configuration value set to True | +| 9 | Verify O-CU sends UE Context Setup Request towards target O-DU | <b>O-DU ← O-CU</b> | Verify O-CU includes following in UE Context Setup Request <ul style="list-style-type: none"> <li>. List of DRB to be setup list</li> <li>. Handover Preparation Information within CUtoDURRCInformation</li> </ul> | +| 10 | Verify target O-DU sends UE Context Setup Response towards O-CU | <b>O-DU → O-CU</b> | Verify target O-DU includes following in UE Context Setup Response <ul style="list-style-type: none"> <li>. List of DRB successfully admit</li> <li>. List of DRB failed to admit</li> <li>. DUtoCURRCInformation</li> </ul> | +| 11 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU ← O-CU</b> | Verify O-CU includes following in UE Context Modification Request <ul style="list-style-type: none"> <li>. RRC-Container for sending RRC Reconfiguration towards UE</li> <li>. Transmission Action Indicator set to Stop</li> </ul> | +| 12 | Verify source O-DU forwards received RRC Reconfiguration towards UE | <b>UE → O-DU</b> | Verify UE received following in RRC Reconfiguration <ul style="list-style-type: none"> <li>. ReconfigurationWithSync <ul style="list-style-type: none"> <li>- spCellConfigCommon</li> <li>- newUE-Identity</li> <li>- t304</li> <li>- rach-ConfigDedicated</li> </ul> </li> </ul> | +| 13 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify O-CU receives UE Context Modification Response successfully | +| 14 | Verify UE triggers CFRA RACH based on configuration received in RRC Reconfiguration RACH towards target O-DU | <b>UE → O-DU</b> | Verify CFRA RACH process is successful within defined timer t304 towards target O-DU | + +| | | | | +|----|-----------------------------------------------------------------------------------------------------------|-----------------------|----------------------------------------------------------------------------------------------------------------------------| +| 15 | Verify UE sends RRC Reconfiguration Complete towards target O-DU | <b>UE → O-DU</b> | Verify target O-DU receives RRC Reconfiguration Complete successfully | +| 16 | Verify target O-DU forwards received RRC Reconfiguration Complete in UL RRC Message Transfer towards O-CU | <b>UE → O-DU</b> | Verify O-CU receives UL RRC Message transfer over F1 interface successfully from target O-DU | +| 17 | Verify data transfer towards UE successful through target O-DU | <b>UE ↔ O-DU/O-CU</b> | Verify end to end data transfer is successful for those PDU Session/QFIs which was successfully handed over to target O-DU | +| 18 | Verify O-CU sends UE Context Release Command towards source O-DU | <b>O-DU ← O-CU</b> | Verify UE Context Release command contains cause as below<br>Cause: radioNetwork<br>radioNetwork: normal-release | +| 19 | Verify source O-DU sends UE Context Release Complete towards O-CU | <b>O-DU → O-CU</b> | Verify O-CU receives UE Context Release Command successfully from source O-DU | + +## 7.52 ORAN.WG8.IOT.051: Verify successful inter frequency measurement based inter-O-DU handover within an O-CU + +### 7.52.1 Test Purpose + +The purpose of this test case is to verify successful inter frequency measurement based inter-O-DU handover within an O-CU. + +### 7.52.2 Reference Requirement + +For detailed requirements, refer to the section 10.2.2 in ORAN-WG8.AAD [1]. + +### 7.52.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU's. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. + +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.52.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU's, O-CU and O-RU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.6. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.52.5 Test Procedure + +The following table describes the test procedures to verify successful inter frequency measurement based inter-O-DU handover within an O-CU. + +**Table 7.52-1: Verify successful inter frequency measurement based inter-O-DU handover within an O-CU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|------------------------------------------------------------------------|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends cell configuration to O-DU. | <b>O-DU ← SMO</b> | Verify SMO sends below mandatory IEs configured for inter O-DU HO within an O-CU towards O-CU cellIndividualOffset <ul style="list-style-type: none"> <li>• rsrpOffsetSSB</li> <li>• rsrqOffsetSSB</li> <li>• sinrOffsetSSB</li> <li>• rsrpOffsetCSI-RS</li> <li>• rsrqOffsetCSI-RS</li> <li>• sinrOffsetCSI-RS</li> </ul> isHOAllowed<br>nRFreqRelationRef<br>adjacentNRCCellRef | +| 2 | Verify cell bring up successful for both O-DU with different frequency | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO. | + +| | | | | +|----|---------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify each O-DU sends mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 3 | Trigger registration procedure for UE with source O-DU | <b>UE <math>\leftrightarrow</math> O-DU/O-CU</b> | <p>Verify registration procedure is successful. O-CU allocates MeasConfig containing following in RRC Reconfiguration</p> <ul style="list-style-type: none"> <li>. MeasObjectToAddModList</li> <li>. ReportConfigToAddModList</li> <li>. MeasIdToAddModList</li> <li>. measGapConfig</li> </ul> | +| 4 | Trigger UDP/TCP data transfer | <b>UE <math>\leftrightarrow</math> O-DU/O-CU</b> | Verify end to end data transfer is successful | +| 5 | Move UE from source cell towards target cell so that UE triggers Measurement Report when criteria for defined event within ReportConfig met | <b>UE <math>\rightarrow</math> O-DU</b> | <p>Verify UE reports configured event within MeasConfig containing following measured during Measurement gap</p> <ul style="list-style-type: none"> <li>. MeasId</li> <li>. measResultNeighCells <ul style="list-style-type: none"> <li>-MeasResultListNR</li> <li>-physCellId</li> <li>-measResult</li> </ul> </li> </ul> | +| 6 | Verify O-DU forwards received Measurement Report towards O-CU in UL RRC Message transfer | <b>O-DU <math>\rightarrow</math> O-CU</b> | Verify source O-DU includes received measurement report within RRC Container. O-CU validates received measurement report of neighbor cell and if neighbor cell satisfies defined criteria for triggering HO at O-CU then HO towards target O-DU gets triggered. | +| 7 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU <math>\leftarrow</math> O-CU</b> | Verify O-CU have included IE GNB-DU Configuration Query set to True | +| 8 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU <math>\rightarrow</math> O-CU</b> | Verify source O-DU includes IE DU To CU RRC Information, Full Configuration and Full Configuration value set to True | +| 9 | Verify O-CU sends UE Context Setup Request towards target O-DU | <b>O-DU <math>\leftarrow</math> O-CU</b> | <p>Verify O-CU includes following in UE Context Setup Request</p> <ul style="list-style-type: none"> <li>. List of DRB to be setup list</li> <li>. Handover Preparation Information within CUtoDURRRCInformation</li> </ul> | +| 10 | Verify target O-DU sends UE Context Setup Response towards O-CU | <b>O-DU <math>\rightarrow</math> O-CU</b> | <p>Verify target O-DU includes following in UE Context Setup Response</p> <ul style="list-style-type: none"> <li>. List of DRB successfully admitted</li> <li>. DUtoCURRRCInformation</li> </ul> | +| 11 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU <math>\leftarrow</math> O-CU</b> | <p>Verify O-CU includes following in UE Context Modification Request</p> <ul style="list-style-type: none"> <li>. RRC-Container for sending RRC Reconfiguration towards UE</li> <li>. Transmission Action Indicator set to Stop</li> </ul> | +| 12 | Verify source O-DU forwards received RRC Reconfiguration towards UE | <b>UE <math>\rightarrow</math> O-DU</b> | <p>Verify UE received following in RRC Reconfiguration</p> <ul style="list-style-type: none"> <li>. ReconfigurationWithSync <ul style="list-style-type: none"> <li>- spCellConfigCommon</li> <li>- newUE-Identity</li> <li>- t304</li> </ul> </li> </ul> | + +| | | | | +|----|--------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------------------------------------| +| | | | - rach-ConfigDedicated | +| 13 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify O-CU receives UE Context Modification Response successfully | +| 14 | Verify UE triggers CFRA RACH based on configuration received in RRC Reconfiguration RACH towards target O-DU | <b>UE → O-DU</b> | Verify CFRA RACH process is successful within defined timer t304 towards target O-DU | +| 15 | Verify UE sends RRC Reconfiguration Complete towards target O-DU | <b>UE → O-DU</b> | Verify target O-DU receives RRC Reconfiguration Complete successfully | +| 16 | Verify target O-DU forwards received RRC Reconfiguration Complete in UL RRC Message Transfer towards O-CU | <b>UE → O-DU</b> | Verify O-CU receives UL RRC Message transfer over F1 interface successfully from target O-DU | +| 17 | Verify data transfer towards UE successful through target O-DU | <b>UE ↔ O-DU/O-CU</b> | Verify end to end data transfer is successful | +| 18 | Verify O-CU sends UE Context Release Command towards source O-DU | <b>O-DU ← O-CU</b> | Verify UE Context Release command contains cause as below<br>Cause: radioNetwork<br>radioNetwork: normal-release | +| 19 | Verify source O-DU sends UE Context Release Complete towards O-CU | <b>O-DU → O-CU</b> | Verify O-CU receives UE Context Release Command successfully from source O-DU | + +## 7.53 ORAN.WG8.IOT.052: Verify HO preparation failure at target O-DU during inter-O-DU handover within an O-CU + +### 7.53.1 Test Purpose + +The purpose of this test case is to verify HO preparation failure at target O-DU during inter-O-DU handover within an O-CU. + +### 7.53.2 Reference Requirement + +For detailed requirements, refer to the section 10.2.2 in ORAN-WG8.AAD [1]. + +### 7.53.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. + +- O-CU is connected to O-DU's. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.53.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU's, O-CU and O-RU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.6. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +### 7.53.5 Test Procedure + +The following table describes the test procedures to verify HO preparation failure at target O-DU during inter-O-DU handover within an O-CU. + +**Table 7.53-1: Verify HO preparation failure at target O-DU during inter-O-DU handover within an O-CU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|---------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends cell configuration to O-DU. | <b>O-DU ← SMO</b> | <p>Verify SMO sends below mandatory IEs configured for inter O-DU HO within an O-CU towards O-CU cellIndividualOffset</p> <ul style="list-style-type: none"> <li>• rsrpOffsetSSB</li> <li>• rsrqOffsetSSB</li> <li>• sinrOffsetSSB</li> <li>• rsrpOffsetCSI-RS</li> <li>• rsrqOffsetCSI-RS</li> <li>• sinrOffsetCSI-RS</li> </ul> <p>isHOAllowed<br/>nRFreqRelationRef<br/>adjacentNRCellRef</p> | +| 2 | Verify cell bring up successful for both O-DU | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>Verify each O-DU sends mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 3 | Trigger registration procedure for UE with Source O-DU | <b>UE ↔ O-DU/O-CU</b> | <p>Verify registration procedure is successful</p> <p>O-CU allocates MeasConfig containing following in RRC Reconfiguration</p> <ul style="list-style-type: none"> <li>. MeasObjectToAddModList</li> <li>. ReportConfigToAddModList</li> <li>. MeasIdToAddModList</li> </ul> | +| 4 | Trigger UDP/TCP data transfer | <b>UE ↔ O-DU/O-CU</b> | Verify end to end data transfer is successful | +| 5 | Move UE from source cell towards target cell so that UE triggers Measurement Report when criteria for defined event within ReportConfig met | <b>UE → O-DU</b> | <p>Verify UE reports configured event on defined criteria within MeasConfig containing following</p> <ul style="list-style-type: none"> <li>. MeasId</li> <li>. measResultNeighCells <ul style="list-style-type: none"> <li>-MeasResultListNR</li> <li>-physCellId</li> <li>-measResult</li> </ul> </li> </ul> | +| 6 | Verify O-DU forwards received Measurement Report towards O-CU in UL RRC Message transfer | <b>O-DU → O-CU</b> | Verify source O-DU includes received measurement report within RRC Container. O-CU validates received measurement report of neighbor cell and if neighbor cell satisfies defined criteria for triggering HO at O-CU then HO towards target O-DU gets triggered. | +| 7 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU ← O-CU</b> | Verify O-CU have included IE GNB-DU Configuration Query set to True | +| 8 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify source O-DU includes IE DU To CU RRC Information, Full Configuration and Full Configuration value set to True | +| 9 | Verify O-CU sends UE Context Setup Request towards target O-DU | <b>O-DU ← O-CU</b> | <p>Verify O-CU includes following in UE Context Setup Request</p> <ul style="list-style-type: none"> <li>. List of DRB to be setup list</li> <li>. Handover Preparation Information within CUtoDURRCInformation</li> </ul> | + +| | | | | +|----|----------------------------------------------------------------------------------------|-------------|----------------------------------------------------------------------------------------| +| 10 | Verify target O-DU sends UE Context Setup Failure towards O-CU as cell is fully loaded | O-DU → O-CU | Verify target O-DU includes appropriate cause in UE Context Setup Failure towards O-CU | +|----|----------------------------------------------------------------------------------------|-------------|----------------------------------------------------------------------------------------| + +## 7.54 ORAN.WG8.IOT.053: Verify RRC Re-establishment received at O-CU when HO execution fails during inter-O-DU handover within an O-CU + +### 7.54.1 Test Purpose + +The purpose of this test case is to verify RRC Re-establishment received at O-CU when HO execution fails during inter-O-DU handover within an O-CU. + +### 7.54.2 Reference Requirement + +For detailed requirements, refer to the section 10.2.2 in ORAN-WG8.AAD [1]. + +### 7.54.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU's. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.54.4 Test Setup and Configuration + +- DUTs:** SMO, O-DU's, O-CU and O-RU + +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer: used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.6. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.54.5 Test Procedure + +The following table describes the test procedures to verify RRC Re-establishment received at O-CU when HO execution fails during inter-O-DU handover within an O-CU. + +**Table 7.54-1: Procedure to verify RRC Re-establishment received at O-CU when HO execution fails during inter-O-DU handover within an O-CU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends cell configuration to O-DU. | <b>O-DU ← SMO</b> | Verify SMO sends below mandatory IEs configured for inter O-DU HO within an O-CU towards O-CU cellIndividualOffset <ul style="list-style-type: none"> <li>• rsrpOffsetSSB</li> <li>• rsrqOffsetSSB</li> <li>• sinrOffsetSSB</li> <li>• rsrpOffsetCSI-RS</li> <li>• rsrqOffsetCSI-RS</li> <li>• sinrOffsetCSI-RS</li> <li>• isHOAllowed</li> <li>• nRFreqRelationRef</li> <li>• adjacentNRCellRef</li> </ul> | +| 2 | Verify cell bring up successful for both O-DU | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>Verify each O-DU sends mandatory cell configuration to O-RU and ensures that O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED.<br><br>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify O-DU sets the administrative state to UNLOCKED state. | + +| | | | | +|----|---------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3 | Trigger registration procedure for UE with source O-DU | <b>UE ↔ O-DU/O-CU</b> | Verify registration procedure is successful. O-CU allocates MeasConfig containing following within RRC Reconfiguration <ul style="list-style-type: none"> <li>. MeasObjectToAddModList</li> <li>. ReportConfigToAddModList</li> <li>. MeasIdToAddModList</li> </ul> | +| 4 | Trigger UDP/TCP data transfer | <b>UE ↔ O-DU/O-CU</b> | Verify end to end data transfer is successful | +| 5 | Move UE from source cell towards target cell so that UE triggers Measurement Report when criteria for defined event within ReportConfig met | <b>UE → O-DU</b> | Verify UE reports configured event on defined criteria within MeasConfig containing following <ul style="list-style-type: none"> <li>. MeasId</li> <li>. measResultNeighCells <ul style="list-style-type: none"> <li>-MeasResultListNR</li> <li>-physCellId</li> <li>-measResult</li> </ul> </li> </ul> | +| 6 | Verify O-DU forwards received Measurement Report towards O-CU in UL RRC Message transfer | <b>O-DU → O-CU</b> | Verify source O-DU includes received measurement report within RRC Container. O-CU validates received measurement report of neighbor cell and if neighbor cell satisfies defined criteria for triggering HO at O-CU then HO towards target O-DU gets triggered. | +| 7 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU ← O-CU</b> | Verify O-CU have included IE GNB-DU Configuration Query set to True | +| 8 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify source O-DU includes IE DU To CU RRC Information, Full Configuration and Full Configuration value set to True | +| 9 | Verify O-CU sends UE Context Setup Request towards target O-DU | <b>O-DU ← O-CU</b> | Verify O-CU includes following in UE Context Setup Request <ul style="list-style-type: none"> <li>. List of DRB to be setup list</li> <li>. Handover preparation Information within CUtoDURRCInformation</li> </ul> | +| 10 | Verify target O-DU sends UE Context Setup Response towards O-CU | <b>O-DU → O-CU</b> | Verify target O-DU includes following in UE Context Setup Response <ul style="list-style-type: none"> <li>. List of DRB successfully admitted</li> <li>. DUtoCURRCInformation</li> </ul> | +| 11 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU ← O-CU</b> | Verify O-CU includes following in UE Context Modification Request <ul style="list-style-type: none"> <li>. RRC-Container for sending RRC Reconfiguration towards UE</li> <li>. Transmission Action Indicator set to Stop</li> </ul> | +| 12 | Verify source O-DU forwards received RRC Reconfiguration towards UE | <b>UE → O-DU</b> | Verify UE received following in RRC Reconfiguration <ul style="list-style-type: none"> <li>. ReconfigurationWithSync <ul style="list-style-type: none"> <li>- spCellConfigCommon</li> <li>- newUE-Identity</li> <li>- t304</li> <li>- rach-ConfigDedicated</li> </ul> </li> </ul> | +| 13 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify O-CU receives UE Context Modification Response successfully | +| 14 | RACH process towards target cell gets failed so UE trigger's RRC Re-establishment Request towards source O-DU due to Handover Failure | <b>UE → O-DU</b> | Verify RRC Re-establishment Request contains following <ul style="list-style-type: none"> <li>. C-RNTI</li> <li>. Physical cell id</li> <li>. MAC-I</li> <li>. Re-establishment cause</li> </ul> | + +| | | | | +|----|-------------------------------------------------------------------------------------------------------------------|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 15 | Verify source O-DU forwards received RRC Re-establishment Request towards O-CU in Initial UL RRC Message Transfer | <b>O-DU → O-CU</b> | Verify O-CU receives RRC Re-establishment Request successfully | +| 16 | Verify O-CU sends RRC Re-establishment request towards source O-DU in DL RRC Message Transfer | <b>O-DU ← O-CU</b> | Verify Source O-DU receives DL RRC Message transfer successfully | +| 17 | Verify source O-DU forwards received RRC Re-establishment towards UE | <b>UE ← O-DU</b> | Verify source O-DU sends RRC Re-establishment towards UE | +| 18 | Verify UE sends RRC Re-establishment complete towards O-DU | <b>UE → O-DU</b> | Verify O-DU receives RRC Re-establishment complete | +| 19 | Verify source O-DU sends received RRC Re-establishment complete towards O-CU in UL RRC Message transfer | <b>O-DU → O-CU</b> | Verify O-CU receives RRC Re-establishment complete successfully from source O-DU | +| 20 | Verify O-CU sends UE Context Modification Request towards source O-DU | <b>O-DU ← O-CU</b> | Verify O-CU have included IE GNB-DU Configuration Query set to True | +| 21 | Verify source O-DU sends UE Context Modification Response towards O-CU | <b>O-DU → O-CU</b> | Verify source O-DU includes IE DU To CU RRC Information, Full Configuration and Full Configuration value set to True | +| 22 | Verify O-CU sends RRC Reconfiguration towards source O-DU within DL RRC Message transfer | <b>O-DU ← O-CU</b> | Verify Source O-DU receives DL RRC Message transfer successfully | +| 23 | Verify source O-DU forwards RRC Reconfiguration towards UE | <b>UE ← O-DU</b> | Verify UE Receives RRC Reconfiguration successfully | +| 24 | Verify UE sends RRC Reconfiguration Complete towards source O-DU | <b>UE → O-DU</b> | Verify source O-DU receives RRC Reconfiguration Complete successfully | +| 25 | Verify source O-DU sends received RRC Reconfiguration towards O-CU in UL RRC message transfer | <b>O-DU → O-CU</b> | Verify O-CU successfully received RRC Reconfiguration Complete | +| 26 | Verify target O-DU triggers UE Context Release Request after timer t304 expiry | <b>O-DU → O-CU</b> | As no RACH is received at target O-DU so timer t304 will expire and target O-DU will send UE Context Release Request towards O-CU. Verify O-CU receives UE Context Release Request successfully | +| 27 | Verify O-CU sends UE Context Release Command towards target O-DU | <b>O-DU ← O-CU</b> | Verify target O-DU receives UE Context Release Command and clears UE context successfully | +| 28 | Verify target O-DU sends UE Context Release Complete towards O-CU | <b>O-DU → O-CU</b> | Verify O-CU receives UE Context Release Complete successfully | + +## 7.55 ORAN.WG8.IOT.054: Verify beam failure detection and recovery using SSB for detection as well as recovery with DRX disabled and 64 beams for FR2 configuration. + +### 7.55.1 Test Purpose + +The purpose of this test case is to verify detection of beam failure using radio link monitoring configuration and recovery of the same using beam failure recovery configuration. Few parameters from both these configurations for beam failure detection and recovery are provided by SMO to O-DU, and these are configured to UE through RRC message. + +### 7.55.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.4.2.5, 11.2.4.2.6 and 11.2.5.1.11 in ORAN-WG8.AAD [1]. + +### 7.55.3 Initial Condition + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.55.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. + +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.4. +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.55.5 Test Procedure + +The following table describes the test procedures for beam failure detection and recovery using SSB for FR2 when DRX is disabled. + +**Table 7.55-1: Beam failure detection and recovery using SSB for FR2** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------------------------------------------|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming and beam failure information received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <p>Beamforming configuration:</p> <ul style="list-style-type: none"> <li>• ssb-PositionsInBurst <ul style="list-style-type: none"> <li>◦ groupPresence = 11111111</li> <li>◦ inOneGroup =11111111</li> </ul> </li> <li>• ssb-periodicityServingCell</li> <li>• subCarrierSpacingCommon</li> <li>• ssb-SubcarrierOffset (0-11)</li> <li>• numTxAnt</li> <li>• numRxAnt</li> <li>• numofBeams (64)</li> <li>• numTXRUs (64)</li> <li>• beamIndex (64)</li> <li>• beamType</li> <li>• beamAzimuth</li> <li>• beamTilt</li> <li>• beamHorizWidth</li> <li>• beamVertWidth</li> <li>• coverageShape</li> <li>• digitalTilt</li> <li>• digitalAzimuth</li> <li>• numAntPorts (64)</li> </ul> | + +| | | | | +|---|----------------------------------------------------------------------------|----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <ul style="list-style-type: none"> <li>numLayers</li> </ul> <p>Beam failure configuration:</p> <ul style="list-style-type: none"> <li>beamFailureDetectionTimer</li> <li>beamFailureInstanceMaxCount</li> <li>powerControlOffsetSS</li> <li>rsrp-ThresholdSSB</li> <li>beamFailureRecoveryTimer</li> <li>rlmInSyncOutOfSyncThreshold</li> </ul> | +| 2 | Cell configuration with beamforming information received from O-DU to O-RU | <b>O-RU ← O-DU</b> | <p>Verify O-DU sends the beamforming configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration and the state of O-RU is changed to INACTIVE.</p> | +| 3 | Cell configuration update response received from O-RU to O-DU | <b>O-RU → O-DU</b> | <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.</p> <p>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE.</p> | +| 4 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the new configuration received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 5 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | <p>Verify UE attaches successfully.</p> <p>Verify RadioLinkMonitoringConfig (detectionResource SSB) and BeamFailureRecoveryConfig (candidateBeamRSList SSB with preamble index) are sent to the UE in RRC message.</p> | +| 6 | End to end data validation | <b>UE ↔ O-DU/ O-CU<br/>↔ UPF</b> | <p>Verify end to end data is successful</p> | +| 7 | Move the UE from Cell Center to Cell Edge | <b>UE ↔ O-DU</b> | <p>The RF signal gets degraded and BLER level goes beyond rlmInSyncOutOfSyncThreshold (Qout for out of sync) [Table 8.1.1.1 of 38.133 [30]].</p> <p>Verify UE detects beam failure and it starts beam recovery procedure.</p> <p>Verify UE selects the beam with highest rsrp-ThresholdSSB from candidateBeamRSList (provided in BeamFailureRecoveryConfig) and sends contention free RACH (or contention based in case the rsrp-ThresholdSSB is not met).</p> <p>Verify that, beam failure recovery is successful, and end to end data continues after beam recovery.</p> | + +## 7.56 ORAN.WG8.IOT.055: Verify beam failure detection and recovery using SSB for detection as well as recovery with DRX disabled and 8 beams for FR1 configuration. + +### 7.56.1 Test Purpose + +The purpose of this test case is to verify detection of beam failure using radio link monitoring configuration and recovery of the same using beam failure recovery configuration. Few parameters from both these configurations for beam failure detection and recovery are provided by SMO to O-DU, and these are configured to UE through RRC message. + +### 7.56.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.4.2.5, 11.2.4.2.6 and 11.2.5.1.11 in ORAN-WG8.AAD [1]. + +### 7.56.3 Initial Condition + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.56.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. + +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.4. +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.56.5 Test Procedure + +The following table describes the test procedures for beam failure detection and recovery using SSB for FR1 when DRX is disabled. + +**Table 7.56-1: Beam failure detection and recovery using SSB for FR1** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|--------------------------------------------------------------------------------------------|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming and beam failure information received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <p>Beamforming configuration:</p> <ul style="list-style-type: none"> <li>ssb-PositionsInBurst</li> <li>inOneGroup =11111111</li> <li>ssb-periodicityServingCell</li> <li>subCarrierSpacingCommon</li> <li>ssb-SubcarrierOffset</li> <li>numTxAnt</li> <li>numRxAnt</li> <li>numofBeams (8)</li> <li>numTXRUs (8)</li> <li>beamIndex (8)</li> <li>beamType</li> <li>beamAzimuth</li> <li>beamTilt</li> <li>beamHorizWidth</li> <li>beamVertWidth</li> <li>coverageShape</li> <li>digitalTilt</li> <li>digitalAzimuth</li> <li>numAntPorts (8)</li> <li>numLayers</li> </ul> <p>Beam failure configuration:</p> <ul style="list-style-type: none"> <li>beamFailureDetectionTimer</li> <li>beamFailureInstanceMaxCount</li> <li>powerControlOffsetSS</li> <li>rsrp-ThresholdSSB</li> <li>beamFailureRecoveryTimer</li> <li>rlmInSyncOutOfSyncThreshold</li> </ul> | +| 2 | Cell configuration with beamforming information received from O-DU to O-RU | <b>O-RU ← O-DU</b> | <p>Verify O-DU sends the beamforming configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration, and the state of O-RU is changed to INACTIVE.</p> | +| 3 | Cell configuration update Response received from O-RU to O-DU | <b>O-RU → O-DU</b> | <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.</p> <p>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE.</p> | +| 4 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | + +| | | | | +|---|-------------------------------------------|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 5 | Attach validation | UE ↔ O-DU/O-CU | Verify UE attaches successfully.<br>Verify RadioLinkMonitoringConfig (detectionResource SSB) and BeamFailureRecoveryConfig (candidateBeamRSList SSB with preamble index) are sent to the UE in RRC message. | +| 6 | End to end data validation | UE ↔ O-DU/ O-CU<br>↔ UPF | Verify end to end data is successful | +| 7 | Move the UE From Cell Center to Cell Edge | UE ↔ O-DU | The RF signal gets degraded and BLER level goes beyond $rlmInSyncOutOfSyncThreshold$ (Qout for out of sync) [Table 8.1.1.1 of 38.133 [30]].<br><br>Verify UE detects beam failure, and it starts beam recovery procedure.<br><br>Verify UE selects the beam with highest $rsrp-ThresholdSSB$ from candidateBeamRSList (provided in BeamFailureRecoveryConfig) and sends contention free RACH (or contention based in case the $rsrp-ThresholdSSB$ is not met).<br><br>Verify that, beam failure recovery is successful, and end to end data continues after beam recovery. | + +## 7.57 ORAN.WG8.IOT.056: Verify beam failure detection and recovery using SSB for detection as well as recovery with DRX enabled and 8 beams for FR1 configuration. + +### 7.57.1 Test Purpose + +The purpose of this test case is to verify detection of beam failure using radio link monitoring configuration and recovery of the same using beam failure recovery configuration. Few parameters from both these configurations for beam failure detection and recovery are provided by SMO to O-DU, and these are configured to UE through RRC message. + +### 7.57.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.4.2.5, 11.2.4.2.6 and 11.2.5.1.11 in ORAN-WG8.AAD [1]. + +### 7.57.3 Initial Condition + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. + +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.57.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.57.5 Test Procedure + +The following table describes the test procedures for beam failure detection and recovery when using SSB for FR1 when DRX is enabled. + +**Table 7.57-1: Beam failure detection and recovery using SSB for FR1 with DRX enabled** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|--------------------------------------------------------------------------------------------|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming and beam failure information received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <p>Beamforming configuration:</p> <ul style="list-style-type: none"> <li>ssb-PositionsInBurst <ul style="list-style-type: none"> <li>inOneGroup =11111111</li> </ul> </li> <li>ssb-periodicityServingCell</li> <li>subCarrierSpacingCommon</li> <li>ssb-SubcarrierOffset</li> <li>numTxAnt</li> <li>numRxAnt</li> <li>numofBeams (8)</li> <li>numTXRUs (8)</li> <li>beamIndex (8)</li> <li>beamType</li> <li>beamAzimuth</li> <li>beamTilt</li> <li>beamHorizWidth</li> <li>beamVertWidth</li> <li>coverageShape</li> <li>digitalTilt</li> <li>digitalAzimuth</li> <li>numAntPorts (8)</li> <li>numLayers</li> </ul> <p>Beam failure configuration:</p> <ul style="list-style-type: none"> <li>beamFailureDetectionTimer</li> <li>beamFailureInstanceMaxCount</li> <li>powerControlOffsetSS</li> <li>rsrp-ThresholdSSB</li> <li>beamFailureRecoveryTimer</li> <li>rlmInSyncOutOfSyncThreshold</li> </ul> | +| 2 | Cell configuration with beamforming information received from O-DU to O-RU | <b>O-RU ← O-DU</b> | <p>Verify O-DU sends the beamforming configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration and the state of O-RU is changed to INACTIVE.</p> | +| 3 | Cell configuration update Response is sent from O-RU to O-DU | <b>O-RU → O-DU</b> | <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.</p> <p>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE.</p> | +| 4 | Cell configuration with DRX information received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify below configuration IE's are received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <ul style="list-style-type: none"> <li>drx-on-duration-timer</li> <li>drx-inactivity-timer</li> <li>drx-harq-rtt-timer-dl</li> <li>drx-harq-rtt-timer-ul</li> <li>drx-retransmission-timer-dl</li> <li>drx-retransmission-timer-ul</li> <li>drx-long-cycle</li> <li>drx-short-cycle</li> <li>drx-short-cycle-timer</li> <li>Refer O-RAN WG5 specification(o-ran_3gpp-nr-nrm-gnbdufunction.yang) [29].</li> </ul> | + +| | | | | +|---|-------------------------------------------|----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 5 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 6 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | <p>Verify UE attaches successfully.</p> <p>Verify RadioLinkMonitoringConfig (detectionResource SSB) and BeamFailureRecoveryConfig (candidateBeamRSList SSB with preamble index) are sent to the UE in RRC message.</p> <p>Verify that drx config is received by UE in RRC message.</p> | +| 7 | End to end data validation | <b>UE ↔ O-DU/ O-CU<br/>↔ UPF</b> | Verify end to end data is successful | +| 8 | Move the UE From Cell Center to Cell Edge | <b>UE ↔ O-DU</b> | <p>The RF signal gets degraded and BLER level goes beyond rlmInSyncOutOfSyncThreshold (Qout for out of sync) [Table 8.1.1.1 of 38.133 [30]].</p> <p>Verify UE detects beam failure and it starts beam recovery procedure.</p> <p>Verify UE selects the beam with power level more than rsrp-ThresholdSSB from candidateBeamRSList (provided in BeamFailureRecoveryConfig) and sends contention free RACH (or contention based in case the rsrp-ThresholdSSB is not met).</p> <p>Verify that, beam failure recovery is successful, and end to end data continues after beam recovery.</p> | + +## 7.58 ORAN.WG8.IOT.057: Verify beam failure detection and recovery using CSI-RS for detection as well as recovery with DRX disabled and 32 beams for FR2 configuration. + +### 7.58.1 Test Purpose + +The purpose of this test case is to verify detection of beam failure using radio link monitoring configuration and recovery of the same using beam failure recovery configuration. Few parameters from both these configurations for beam failure detection and recovery are provided by SMO to O-DU, and these are configured to UE through RRC message. + +## 7.58.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.4.2.5, 11.2.4.2.6 and 11.2.5.1.11 in ORAN-WG8.AAD [1]. + +## 7.58.3 Initial Condition + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.58.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.58.5 Test Procedure + +The following table describes the test procedures for beam failure detection and recovery when using CSI-RS when DRX is disabled and 32 beams are configured. + +**Table 7.58-1: Beam failure detection and recovery using CSI-RS for FR2** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------------------------------------------|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming and beam failure information received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <p>Beamforming configuration:</p> <ul style="list-style-type: none"> <li>• ssb-PositionsInBurst <ul style="list-style-type: none"> <li>◦ groupPresence = 11111111</li> <li>◦ inOneGroup = 10101010</li> </ul> </li> <li>• ssb-periodicityServingCell</li> <li>• subCarrierSpacingCommon</li> <li>• ssb-SubcarrierOffset</li> <li>• numTxAnt</li> <li>• numRxAnt</li> <li>• numofBeams (64)</li> <li>• numTXRUs (64)</li> <li>• beamIndex (64)</li> <li>• beamType</li> <li>• beamAzimuth</li> <li>• beamTilt</li> <li>• beamHorizWidth</li> <li>• beamVertWidth</li> <li>• coverageShape</li> <li>• digitalTilt</li> <li>• digitalAzimuth</li> <li>• numAntPorts (64)</li> <li>• numLayers</li> </ul> <p>Beam failure configuration:</p> <ul style="list-style-type: none"> <li>• beamFailureDetectionTimer</li> <li>• beamFailureInstanceMaxCount</li> <li>• powerControlOffsetSS</li> <li>• rsrp-ThresholdSSB</li> <li>• beamFailureRecoveryTimer</li> <li>• rlmInSyncOutOfSyncThreshold</li> </ul> | +| 2 | Cell configuration with beamforming information received from O-DU to O-RU | <b>O-RU ← O-DU</b> | <p>Verify O-DU sends the beamforming configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration and the state of O-RU is changed to INACTIVE.</p> | +| 3 | Cell configuration update response sent from O-RU to O-DU | <b>O-RU → O-DU</b> | <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.</p> <p>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE.</p> | + +| | | | | +|---|-------------------------------------------|----------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 5 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 6 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | <p>Verify UE attaches successfully.</p> <p>Verify NZP-CSI-RS-Resource is included under the csi-measConfig in RRC message.</p> <p>Verify RadioLinkMonitoringConfig (detectionResource CSI-RS) and BeamFailureRecoveryConfig (candidateBeamRSList CSI-RS with preamble index) are sent to the UE in RRC message.</p> | +| 7 | End to end data validation | <b>UE ↔ O-DU/ O-CU<br/>↔ UPF</b> | Verify end to end data is successful | +| 8 | Move the UE from Cell Center to Cell Edge | <b>UE ↔ O-DU</b> | <p>The RF signal gets degraded and BLER level goes beyond <math>rlmInSyncOutOfSyncThreshold</math> (Qout for out of sync) [Table 8.1.1.1 of 38.133 [30]].</p> <p>Verify UE detects beam failure and it starts beam recovery procedure.</p> <p>Verify UE selects the beam with power level more than the threshold (<math>rsrp-ThresholdSSB + powerControlOffsetSS</math>) from candidateBeamRSList (provided in BeamFailureRecoveryConfig) and sends contention free RACH (or contention based in case the threshold is not met).</p> <p>Verify that, beam failure recovery is successful, and end to end data continues after beam recovery.</p> | + +## 7.59 ORAN.WG8.IOT.058: Verify prioritized random access during beam failure recovery + +### 7.59.1 Test Purpose + +The purpose of this test case is to verify beam failure detection and recovery when the backoff indicator (BI) is scaled to a smaller value and preamble power is incremented by a larger value due to initial RACH failure. Few parameters will be provided by SMO to O-DU rest will be assigned by O-DU, and all of these will be configured to UE through RRC message. + +### 7.59.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.4.2.5, 11.2.4.2.6 and 11.2.5.1.11 in ORAN-WG8.AAD [1]. + +### 7.59.3 Initial Condition + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.59.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.59.5 Test Procedure + +The following table describes the test procedures for prioritized random access during beam failure recovery. + +**Table 7.59-1: Prioritized random access during beam failure recovery** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------------------------------------------|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming and beam failure information received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <p>Beamforming configuration:</p> <ul style="list-style-type: none"> <li>ssb-PositionsInBurst <ul style="list-style-type: none"> <li>groupPresence = 11111111</li> <li>inOneGroup = 10101010</li> </ul> </li> <li>ssb-periodicityServingCell</li> <li>subCarrierSpacingCommon</li> <li>ssb-SubcarrierOffset</li> <li>numTxAnt</li> <li>numRxAnt</li> <li>numofBeams (64)</li> <li>numTXRUs (64)</li> <li>beamIndex (64)</li> <li>beamType</li> <li>beamAzimuth</li> <li>beamTilt</li> <li>beamHorizWidth</li> <li>beamVertWidth</li> <li>coverageShape</li> <li>digitalTilt</li> <li>digitalAzimuth</li> <li>numAntPorts (64)</li> <li>numLayers</li> </ul> <p>Beam failure configuration:</p> <ul style="list-style-type: none"> <li>beamFailureInstanceMaxCount</li> <li>beamFailureDetectionTimer</li> <li>powerControlOffsetSS</li> <li>rsrp-ThresholdSSB</li> <li>beamFailureRecoveryTimer</li> <li>rlmInSyncOutOfSyncThreshold</li> <li>powerRampingStepHighPriority</li> <li>scalingFactorBI</li> </ul> | +| 2 | Cell configuration with beamforming information sent O-DU to O-RU | <b>O-RU ← O-DU</b> | <p>Verify O-DU sends the beamforming configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration and the state of O-RU is changed to INACTIVE.</p> | +| 3 | Cell configuration update with beamforming information received from O-DU to O-RU | <b>O-RU → O-DU</b> | <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.</p> <p>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE.</p> | + +| | | | | +|---|---------------------------------------------------------------------------------------------|----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 4 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 5 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | <p>Verify that UE attaches successfully.</p> <p>Verify that NZP-CSI-RS-Resource is included under the csi-measConfig in RRC message.</p> <p>Verify that RadioLinkMonitoringConfig (detectionResource CSI-RS) and BeamFailureRecoveryConfig (candidateBeamRSList CSI-RS with preamble index) are sent to the UE in RRC message.</p> | +| 6 | End to end data validation | <b>UE ↔ O-DU/ O-CU<br/>↔ UPF</b> | Verify end to end data is successful | +| 7 | Create condition of RACH overload on the O-DU and move the UE from cell center to cell edge | <b>UE ↔ O-DU</b> | <p>The RF signal gets degraded and BLER level goes beyond <math>rlmInSyncOutOfSyncThreshold</math> (Qout for out of sync) [Table 8.1.1.1 of 38.133 [30]].</p> <p>Verify UE detects beam failure and starts beam recovery procedure.</p> <p>Verify UE selects the beam with power level more than threshold (<math>rsrp-ThresholdSSB + powerControlOffsetSS</math>) from candidateBeamRSList (provided in BeamFailureRecoveryConfig) and sends contention free RACH (or contention based in case the threshold is not met).</p> <p>Verify that due to RACH overload, O-DU transmits RAR with BI.</p> <p>Verify UE transmits RACH preamble again on priority by applying scalingFactorBI and powerRampingStepHighPriority.</p> <p>Verify that, beam failure recovery is successful, and end to end data continues after beam recovery.</p> | + +## 7.60 ORAN.WG8.IOT.059: Verify beam failure detection and recovery when SSB/CSI-RS not configured under radioLinkMonitoringConfig. + +### 7.60.1 Test Purpose + +The purpose of this test case is to verify detection of beam failure using PDCCH TCI-State configuration when failureDetectionresources are not included in the radio link monitoring configuration and recovery of the same using beam failure recovery configuration. Few parameters will be provided by SMO to O-DU rest will be assigned by O-DU, and all of these will be configured to UE through RRC message. + +### 7.60.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.4.2.5, 11.2.4.2.6 and 11.2.5.1.11 in ORAN-WG8.AAD [1]. + +### 7.60.3 Initial Condition + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.60.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. + +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.4. +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. +- RadioLinkMonitoringConfig does not contain failureDetectionResources + +## 7.60.5 Test Procedure + +The following table describes the test procedures when SSB/CSI-RS are not configured for beam failure detection. + +**Table 7.60-1: Beam failure detection and recovery when SSB/CSI-RS not configured for detection** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------------------------------------------|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming and beam failure information received from SMO to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <p>Beamforming configuration:</p> <ul style="list-style-type: none"> <li>• ssb-PositionsInBurst <ul style="list-style-type: none"> <li>◦ groupPresence = 11111111</li> <li>◦ inOneGroup =11111111</li> </ul> </li> <li>• ssb-periodicityServingCell</li> <li>• subCarrierSpacingCommon</li> <li>• ssb-SubcarrierOffset (0-11)</li> <li>• numTxAnt</li> <li>• numRxAnt</li> <li>• numofBeams (64)</li> <li>• numTXRUs (64)</li> <li>• beamIndex (64)</li> <li>• beamType</li> <li>• beamAzimuth</li> <li>• beamTilt</li> <li>• beamHorizWidth</li> <li>• beamVertWidth</li> <li>• coverageShape</li> <li>• digitalTilt</li> <li>• digitalAzimuth</li> <li>• numAntPorts (64)</li> </ul> | + +| | | | | +|---|----------------------------------------------------------------------------|---------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <ul style="list-style-type: none"> <li>numLayers</li> </ul> <p>Beam failure configuration:</p> <ul style="list-style-type: none"> <li>beamFailureDetectionTimer</li> <li>beamFailureInstanceMaxCount</li> <li>powerControlOffsetSS</li> <li>rsrp-ThresholdSSB</li> <li>beamFailureRecoveryTimer</li> <li>rlmInSyncOutOfSyncThreshold</li> </ul> | +| 2 | Cell configuration with beamforming information received from O-DU to O-RU | <b>O-RU ← O-DU</b> | <p>Verify O-DU sends the beamforming configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration and the state of O-RU is changed to INACTIVE.</p> | +| 3 | Cell configuration update response is sent from O-RU to O-DU | <b>O-RU → O-DU</b> | <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.</p> <p>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE.</p> | +| 5 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 6 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | <p>Verify that UE attaches successfully.</p> <p>Verify that tci-StatesPDCCCH-ToAddList is received in the controlResourceSet under pdccch.config.</p> <p>Verify that RadioLinkMonitoringConfig (without failureDetectionResources) and BeamFailureRecoveryConfig (candidateBeamRSList SSB with preamble index) are sent to the UE in RRC message.</p> | +| 7 | End to end data validation | <b>UE ↔ O-DU/O-CU<br/>↔ UPF</b> | <p>Verify end to end data is successful</p> | + +| | | | | +|---|-------------------------------------------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 8 | Move the UE From Cell center to Cell Edge | UE ↔ O-DU | <p>Since no reference signals (RS) are provided in RadioLinkMonitoringConfig for beam failure detection, RS configured under tci-StatesPDCCH-ToAddList will be used.</p> <p>The RF signal gets degraded and BLER level goes beyond <code>rlmInSyncOutOfSyncThreshold</code> for the RS configured under <code>tci-StatesPDCCH-ToAddList</code> (Qout for out of sync) [Table 8.1.1.1 of 38.133 [30]].</p> <p>Verify UE detects beam failure and it starts beam recovery procedure.</p> <p>Verify UE selects the beam with power level more than <code>rsrp-ThresholdSSB</code> from <code>candidateBeamRSLIST</code> (provided in <code>BeamFailureRecoveryConfig</code>) and sends contention free RACH (or contention based in case the <code>rsrp-ThresholdSSB</code> is not met).</p> <p>Verify that, beam failure recovery is successful, and end to end data continues after beam recovery.</p> | +|---|-------------------------------------------|-----------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +## 7.61 ORAN.WG8.IOT.060: Verify end-to-end data with different CSI-RS configuration + +### 7.61.1 Test Purpose + +The purpose of the test case is to verify O-DU configures the CSI-RS configuration received from SMO and O-DU configures the same to UE. + +### 7.61.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.1.1 in ORAN-WG8.AAD [1]. + +### 7.61.3 Initial Condition + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. + +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.61.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + - For details on the CSI-RS test profiles, see B.8 Config 1 and Config 3. + +## 7.61.5 Test Procedure + +The following table describes the test procedures UE attach and data transfer with CSI-RS configuration + +**Table 7.61-1: End-to-end data verification with different CSI-RS configuration** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------------------------------------|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with CSI-RS<br>Config 1 information received from SMO to O-DU | <b>O-DU ← SMO</b> | Verify that Config 1 CSI-RS configuration is successfully received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC. | +| 2 | Cell configuration with CSI-RS<br>Config 1 information received from O-DU to O-RU | <b>O-RU ← O-DU</b> | Verify that Config 1 CSI-RS configuration is sent to O-RU and updated successfully. | + +| | | | | +|---|--------------------------------------|---------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration received from SMO.</p> <p>Verify O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 4 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | <p>Verify that UE attaches successfully.</p> <p>Verify that nzp-CSI-RS-ResourceToAddModList is received by the UE in rrcReconfiguraiton message under the CSI-MeasConfig.</p> <p>Verify that values of parameters are as per the configuration (see B.8 Config 1).</p> | +| 5 | End to end data validation | <b>UE ↔ O-DU/O-CU<br/>↔ UPF</b> | Verify end to end data is successful | +| 6 | Repeat all steps for CSI-RS Config 3 | <b>Same as for steps 1-5</b> | <p>Verify that cell setup and UE attach is successful.</p> <p>Verify that nzp-CSI-RS-ResourceToAddModList is received by the UE in rrcReconfiguraiton message under the CSI-MeasConfig.</p> <p>Verify that values of parameters is as per the configuration (see B.8 Config 3):</p> | + +## 7.62 ORAN.WG8.IOT.061: Verify cell bring up is not successful with invalid configuration received from SMO + +### 7.62.1 Test Purpose + +The purpose of the test case is to verify that cell bring up is not successful when invalid CSI-RS configuration is received from SMO. + +### 7.62.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.1.1 in ORAN-WG8.AAD [1]. + +### 7.62.3 Initial Condition + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. + +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.62.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + - For details on the CSI-RS test profiles, see B.8 Config 2. + +## 7.62.5 Test Procedure + +The following table describes the test procedures unsuccessful cell setup when invalid CSI-RS config is used. + +**Table 7.62-1: Procedure to verify unsuccessful cell setup when invalid CSI-RS config is used** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with CSI-RS Config 2 information received from SMO to O-DU | <b>O-DU ← SMO</b> | Verify that Config 2 CSI-RS configuration is successfully received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC. | + +| | | | | +|---|--------------------------------------------------------------------------------|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2 | Cell configuration with CSI-RS Config 2 information received from O-DU to O-RU | <b>O-RU ← O-DU</b> | Verify that Config 2 CSI-RS configuration is successfully received by O-RU and updated successfully. | +| 3 | Cell bring up | <b>O-DU/O-RU</b> | Verify cell bring-up is not successful with the configuration that has been received from SMO. O-DU sends F1SetupRequest to O-CU and O-CU responds with F1SetupResponse. But DU does not initiate gNBConfigurationUpdate to O-CU as noCDM is incorrect cdm-Type for nrOfPorts p2. | + +## 7.63 ORAN.WG8.IOT.062: Verify end-to-end data when SRS is enabled and UE is in mobility + +### 7.63.1 Test Purpose + +The purpose of this test case is to verify O-DU configures the SRS configuration received from SMO and verify the end-to-end throughput based on SRS reported by UE when it is in mobility. + +### 7.63.2 Reference Requirements + +For detailed requirements, refer to the section 11.2.4.3.8 in ORAN-WG8.AAD [1]. + +### 7.63.3 Initial Condition + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. + +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.63.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + - For details on the SRS test profile, see B.9 + +## 7.63.5 Test Procedure + +The following table describes the performance with SRS enabled and UE moving. + +**Table 7.63-1: End-to-end data verification with SRS enabled and UE in mobility** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|----------------------------------------------------------|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration information received from SMO to O-DU | <b>O-DU ← SMO</b> | Verify that Config 1 SRS configuration is successfully received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC. | +| 2 | Cell bring up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration received from SMO.</p> <p>Verify O-RU carrier-state is set to ACTIVE and sync-state is set to LOCKED O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | + +| | | | | +|---|--------------------------------------------|---------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | Verify that UE attaches successfully.<br>Verify that 2 items under srs-ResourceSetToAddModList and at least 1 item under srs-ResourceToAddModList are received by the UE in rrcReconfiguraiton message under the UL BWP config with configured parameters.<br>Verify from FAPI logs as per sec 3.4.10 in FAPI specification [12] that SRS is being received periodically by O-DU from O-RU. | +| 4 | End to end data validation | <b>UE ↔ O-DU/O-CU<br/>↔ UPF</b> | Verify end to end data is successful | +| 5 | Move the UE from cell center to cell edge. | <b>UE ↔ O-DU</b> | Verify that SRSResourceSetIndicator is sent in DCI 0_0 indicating which SRSResourceSet is to be used by UE for transmitting SRS.<br><br>Verify that SRS reports are continuously received at O-DU.<br><br>Verify UL MCS and resource allocation in DCI 0_0 is as per the SRS feedback received from the UE. | + +## 7.64 ORAN.WG8.IOT.063: Verify successful collection and transfer of MAC statistics for MU-MIMO from O-DU-OAM-Agent to SMO. + +### 7.64.1 Test Purpose + +The purpose of this test case is to verify successful collection and transfer of MAC statistics for MU-MIMO from O-DU-OAM-Agent to SMO. + +### 7.64.2 Reference Requirement + +For detailed requirements, refer to the section 11.2.2 in ORAN-WG8.AAD [1]. + +### 7.64.3 Initial Conditions + +- Following are the preconditions for this test. +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. + +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.64.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.4. +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.64.5 Test Procedure + +The following table describes the test procedures to verify successful collection and transfer of MAC statistics for MU-MIMO from O-DU-OAM-Agent to SMO. + +**Table 7.64-1: Successful collection and transfer of MAC statistics to SMO.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|-----------------------------------------------------------------------------|-----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming received from SMO to O-DU. | <b>O-DU ← SMO</b> | <p>Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <p>Beamforming configuration:</p> <ul style="list-style-type: none"> <li>ssb-PositionsInBurst <ul style="list-style-type: none"> <li>groupPresence = 11111111</li> <li>inOneGroup = 11111111</li> </ul> </li> <li>ssb-periodicityServingCell</li> <li>subCarrierSpacingCommon</li> <li>ssb-SubcarrierOffset (0-11)</li> <li>numTxAnt</li> <li>numRxAnt</li> <li>numofBeams (64)</li> <li>numTXRUs (64)</li> <li>beamIndex (64)</li> <li>beamType</li> <li>beamAzimuth</li> <li>beamTilt</li> <li>beamHorizWidth</li> <li>beamVertWidth</li> <li>coverageShape</li> <li>digitalTilt</li> <li>digitalAzimuth</li> <li>numAntPorts (64)</li> <li>numLayers</li> </ul> | +| 2 | Cell configuration with beamforming information received from O-DU to O-RU. | <b>O-RU ← O-DU</b> | <p>Verify O-DU sends the beamforming configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE.</p> | +| 3 | Cell configuration update Response received from O-RU to O-DU. | <b>O-RU → O-DU</b> | <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.</p> <p>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE.</p> | +| 4 | Cell bring-up | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 5 | O-DU/O-RU broadcast SSB beams as per defined periodicity. | <b>UE ← O-RU<br/>← O-DU</b> | <p>Verify the O-RU transmit all the 8 beams with a periodicity of 20ms.</p> <p>Verify UE selects the strongest SSB beam from 8 beams broadcasted and sends RACH request with PRACH config index corresponding to beam selected.</p> | +| 6 | Attach validation | <b>UE ← O-DU/<br/>O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration. | +| 7 | End to end data validation | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify end to end data is successful. | + +| | | | | +|---|------------------------------------------------------------------------------------|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 8 | O-DU collects the performance counters from O-RU and reports it to O-DU-OAM-Agent. | <b>O-RU → O-DU → SMO</b> | <p>Verify the following APIs are sent from O-RU towards O-DU-OAM-Agent containing the performance counters as mentioned in ORAN-WG8.AAD [1]:</p> <ul style="list-style-type: none"> <li>• RSRP/RSRQ/SINR measurements</li> <li>• Measurement for the SSB beam switch</li> <li>• Beam Failure statistics per cell per beam</li> <li>• UL SRS RSRP measurement</li> </ul> | +| 9 | PM Data File ready notification | <b>O-DU → SMO</b> | <p>Verify O-DU-OAM-Agent sends notifyFileReady notification towards SMO as mentioned in [22] with the correct PM File Content and naming as mentioned in [28].</p> <p>SMO successfully received the Performance Measurements file.</p> <p>SMO can use it for parameter optimization and reconfiguration of parameters on O1 interface.</p> | + +## 7.65 ORAN.WG8.IOT.064: Verify O-DU-OAM-Agent successfully download the configuration from SMO for beamforming optimization through "file-download request". + +### 7.65.1 Test Purpose + +The purpose of this test case is to verify O-DU-OAM-Agent successfully download the configuration from SMO for beamforming optimization through "file-download request". + +### 7.65.2 Reference Requirement + +For detailed requirements, refer to the section 11.2.2 in ORAN-WG8.AAD [1]. + +### 7.65.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. + +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.65.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.65.5 Test Procedure + +The following table describes the test procedures to verify O-DU-OAM-Agent successfully download the configuration from SMO for beamforming optimization through "file-download request". + +**Table 7.65-1: O-DU-OAM-Agent successfully downloads the configuration from SMO through "file-download request"** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|----------------------------------------------------------------|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming received from SMO to O-DU. | <b>O-DU ← SMO</b> | Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:<br><br>Beamforming configuration: <ul style="list-style-type: none"> <li>• ssb-PositionsInBurst <ul style="list-style-type: none"> <li>◦ groupPresence = 11111111</li> <li>◦ inOneGroup =11111111</li> </ul> </li> <li>• ssb-periodicityServingCell</li> <li>• subCarrierSpacingCommon</li> <li>• ssb-SubcarrierOffset (0-11)</li> <li>• numTxAnt</li> <li>• numRxAnt</li> <li>• numofBeams (64)</li> <li>• numTXRUs (64)</li> </ul> | + +| | | | | +|---|----------------------------------------------------------------------------|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <ul style="list-style-type: none"> <li>beamIndex (64)</li> <li>beamType</li> <li>beamAzimuth</li> <li>beamTilt</li> <li>beamHorizWidth</li> <li>beamVertWidth</li> <li>coverageShape</li> <li>digitalTilt</li> <li>digitalAzimuth</li> <li>numAntPorts (64)</li> <li>numLayers</li> </ul> | +| 2 | Cell configuration with beamforming information received from O-DU to O-RU | <b>O-RU ← O-DU</b> | <p>Verify O-DU sends the beamforming configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE.</p> | +| 3 | Cell configuration update Response received from O-RU to O-DU. | <b>O-RU → O-DU</b> | <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.</p> <p>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE.</p> | +| 4 | Cell bring-up. | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 5 | O-DU/O-RU broadcast SSB beams as per defined periodicity. | <b>UE ← O-DU/O-CU</b> | <p>Verify the O-RU transmit all the 8 beams with a periodicity of 20ms.</p> <p>Verify UE selects the strongest SSB beam from 8 beams broadcasted and sends RACH request with PRACH config index corresponding to beam selected.</p> | +| 6 | Attach validation. | <b>UE ← O-DU/O-CU</b> | <p>Verify that UE able to attach successfully with above mentioned configuration</p> | +| 7 | End to end data validation. | <b>O-DU/O-CU → UPF</b> | <p>Verify end to end data is successful.</p> | +| 8 | O-DU collects the performance counters and reports it to O-DU-OAM-Agent. | <b>O-DU → SMO</b> | <p>Verify the following APIs are sent from MAC towards O-DU-OAM-Agent containing the performance counters as mentioned in ORAN-WG8.AAD [1]:</p> <ul style="list-style-type: none"> <li>RSRP/RSRQ/SINR measurements</li> <li>Measurement for the SSB beam switch</li> <li>Beam Failure statistics per cell per beam</li> <li>UL SRS RSRP measurement</li> </ul> | +| 9 | PM Data File ready notification by O-DU-OAM-Agent. | <b>O-DU → SMO</b> | <p>Verify O-DU-OAM-Agent sends notifyFileReady notification towards SMO as mentioned in [22] with the correct PM File Content and naming as mentioned in [28].</p> <p>SMO successfully received the Performance Measurements file.</p> | + +| | | | | +|----|-------------------------------------------------------------------------------------|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | SMO can use it for parameter optimization and reconfiguration of parameters on O1 interface. | +| 10 | Optimal beamforming configuration Ready at SMO. | <b>O-DU ← SMO</b> | Verify SMO sends notifyFileReady notification towards O-DU-OAM-Agent as mentioned in section 4.22 of [38] with new beamforming configuration. | +| 11 | File download requested by O-DU-OAM-Agent. | <b>O-DU → SMO</b> | Verify O-DU-OAM-Agent sends "file-download-request" to trigger file download to SMO, including the location of the file. | +| 12 | File download accepted by SMO. | <b>O-DU ← SMO</b> | <p>Verify SMO replies with its ability to begin the download and status as accepted.</p> <p>Verify SMO sends a "downloadFile" notification to O-DU-OAM-Agent with current status of the download as download in progress.</p> <p>Once the download is completed.</p> <p>Verify SMO sends a "downloadFile" notification to O-DU-OAM-Agent with final status of the download as success.</p> | +| 13 | File download at O-RU. | <b>O-RU ← O-DU</b> | Verify O-RU Controller/O-DU sends file-download request to O-RU including the location of the file as mentioned in [24]. | +| 14 | File downloaded at O-RU. | <b>O-RU → O-DU</b> | <p>Verify O-RU sends response towards O-RU Controller/O-DU with status of the file-download request as accepted.</p> <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.</p> | +| 15 | De-activate tx-array-carriers and rx-array-carriers | <b>O-RU ← O-DU</b> | Verify the NETCONF client/O-DU shall deactivate tx-array-carriers and rx-array-carriers in the U-Plane configuration by setting "INACTIVE" for the active parameters if they are ACTIVE. | +| 16 | De-activate the cell from the O-DU. | <b>O-DU → O-CU</b> | <p>O-DU sends the F1AP gNB-DU configuration update to O-CU.</p> <p>F1AP gNB-DU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.5 of ORAN.WG5.C.1 [19].</p> <p>O-DU should de-activate the cell information according to the service-state IE.</p> | +| 17 | Apply new edited beamforming information | <b>O-RU ← O-DU</b> | Verify O-DU updated the new edited beamforming config to O-RU as per o-ran-beamforming.yang as mentioned in [24]. | +| 18 | Activate the cell from the O-DU. | <b>O-DU → O-CU</b> | <p>O-DU sends the F1AP gNB-DU configuration update to O-CU.</p> <p>F1AP gNB-DU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.5 of ORAN.WG5.C.1 [19].</p> <p>O-DU should de-activate the cell information according to the service-state IE.</p> | +| 19 | Activate tx-array-carriers and rx-array-carriers with new beamforming configuration | <b>O-RU ← O-DU</b> | Verify the NETCONF client/O-DU shall activate tx-array-carriers and rx-array-carriers in the U-Plane configuration by setting "ACTIVE" for the in-active parameters. | + +| | | | | +|----|----------------------------|-----------------------------|------------------------------------------------------------------------------------------------------------------| +| 20 | Cell bring-up | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the optimized beamforming configuration that has been received from SMO. | +| 21 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | Verify that UE able to attach successfully. | +| 22 | End to end data validation | <b>O-DU/ O-CU<br/>↔ UPF</b> | Verify end to end data is successful. | + +## 7.66 ORAN.WG8.IOT.065: Verify successful collection and transfer of L1 measurements along with parameter reconfiguration for AI/ML assisted Beam Selection Optimization on E2 interface. + +### 7.66.1 Test Purpose + +The purpose of this test case is to verify successful collection and transfer of L1 measurements along with parameter reconfiguration for AI/ML assisted Beam Selection Optimization on E2 interface. + +### 7.66.2 Reference Requirement + +For detailed requirements, refer to the section 11.4 in ORAN-WG8.AAD [1]. + +### 7.66.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. + +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.66.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.66.5 Test Procedure + +The following table describes the test procedures to verify successful collection and transfer of L1 measurements along with parameter reconfiguration for AI/ML assisted Beam Selection Optimization by O-DU-OAM-Agent on E2 interface. + +**Table 7.66-1: Successful collection and transfer of L1 measurements along with parameter reconfiguration on E2 interface.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------------------------------------------------------|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming received from SMO to O-DU | <b>O-DU ← SMO</b> | Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:<br><br>Beamforming configuration: <ul style="list-style-type: none"> <li>• ssb-PositionsInBurst <ul style="list-style-type: none"> <li>◦ groupPresence = 11111111</li> <li>◦ inOneGroup =11111111</li> </ul> </li> <li>• ssb-periodicityServingCell</li> <li>• subCarrierSpacingCommon</li> <li>• ssb-SubcarrierOffset (0-11)</li> <li>• numTxAnt</li> <li>• numRxAnt</li> <li>• numofBeams (64)</li> <li>• numTXRUs (64)</li> <li>• beamIndex (64)</li> </ul> | + +| | | | | +|----|----------------------------------------------------------------------------|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <ul style="list-style-type: none"> <li>• beamType</li> <li>• beamAzimuth</li> <li>• beamTilt</li> <li>• beamHorizWidth</li> <li>• beamVertWidth</li> <li>• coverageShape</li> <li>• digitalTilt</li> <li>• digitalAzimuth</li> <li>• numAntPorts (64)</li> <li>• numLayers</li> </ul> | +| 2 | Cell configuration with beamforming information received from O-DU to O-RU | <b>O-RU ← O-DU</b> | Verify O-DU sends the beamforming configuration through file download request.<br>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE. | +| 3 | Cell configuration update Response received from O-RU to O-DU. | <b>O-RU → O-DU</b> | Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.<br>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE. | +| 4 | O-DU sends the E2 Setup request to near RT-RIC server. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the E2 Setup request message to near RT-RIC server with all the mandatory IEs. | +| 5 | near RT-RIC server sends E2 Setup Response to O-DU. | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC sends the E2 setup response to O-DU with all the mandatory IEs. | +| 6 | Cell bring-up | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify O-DU sets the administrative state to UNLOCKED state. | +| 7 | O-DU/O-RU broadcast SSB beams as per defined periodicity. | <b>UE ← O-RU ← O-DU</b> | Verify the O-RU transmit all the 8 beams with a periodicity of 20ms.<br>Verify UE selects the strongest SSB beam from 8 beams broadcasted and sends RACH request with PRACH config index corresponding to beam selected. | +| 8 | Attach validation | <b>UE ← O-DU/O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration | +| 9 | End to end data validation | <b>O-DU/O-CU → UPF</b> | Verify end to end data is successful. | +| 10 | near RT-RIC server sends E2 Subscription Request to O-DU. | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC server sends E2 Subscription Request to O-DU with the below measurements mentioned in RIC Action Definition IE, Section 5 of 3GPP Specification [25]: <ul style="list-style-type: none"> <li>• L1-RSRP measurement per UE</li> </ul> | + +| | | | | +|----|---------------------------------------------------------------------------------------------------------------------------|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <ul style="list-style-type: none"> <li>L1-SINR measurement per UE</li> <li>CSI-RS Resource Indicator (CRI)</li> <li>SS/PBCH Block Resource Indicator (SSBRI) per UE</li> </ul> | +| 11 | O-DU sends the E2 Subscription Response to near -RT-RIC server with supported subscription items and not supported items. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the E2 Subscription Response to near-RT-RIC server with “RIC Actions Admitted List” IE filled with O-DU supported list from the SUBSCRIPTION REQUEST and “RIC Actions Not Admitted List” IE filled with O-DU non-supported list. | +| 12 | O-DU sends the periodic report to the subscribed features to near RT-RIC server through RIC INDICATION message. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the periodic report to near RT-RIC server through RIC INDICATION message as per SUBSCRIPTION REQUEST. | +| 13 | Near RT-RIC sends RIC Control Request to O-DU | <b>O-DU ← near RT-RIC</b> | Verify Near-RT RIC sends RIC CONTROL REQUEST to an E2 Node to optimize parameters related to beamforming. | +| 14 | O-DU sends RIC Control Acknowledge to Near RT-RIC | <b>O-DU → near RT-RIC</b> | <p>Verify O-DU sends RIC CONTROL ACKNOWLEDGE to Near-RT RIC to inform Near RT-RIC that the message was received and to provide information on the outcome of the request.</p> <p>O-DU configures O-RU based on the optimized parameters received from Near RT-RIC.</p> | +| 15 | Attach validation | <b>UE ↔ O-DU/O-CU</b> | Verify that UE able to attach successfully. | +| 16 | End to end data validation | <b>O-DU/ O-CU ↔ UPF</b> | Verify end to end data is successful. | + +## 7.67 ORAN.WG8.IOT.066: Verify successful vO-DU and vO-CU deployment on an O-Cloud. + +### 7.67.1 Test Purpose + +The purpose of this test case is to verify successful instantiation of a cloud-native Network Function as a new deployment on an O-Cloud. + +### 7.67.2 Reference Requirement + +For detailed requirements, refer to the section 8.3 and section 9.4 in ORAN-WG8.AAD [1]. + +### 7.67.3 Initial Conditions + +Following are the preconditions for this test. + +- SMO is configured to add an O-Cloud into its inventory prior to the O-Cloud itself being activated. +- O-Cloud ID is generated by the SMO which represents a globally unique identifier for identifying the new O-Cloud instance by the SMO. +- Physical network connectivity exists between the network gateway of O-Cloud and SMO. +- Cloud software installation on O-Cloud and O-Cloud nodes is successful and operational. +- O-RU is implemented as a physical Network Function and deployed remotely. O-RU is managed entirely by vO-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- Use the default vO-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in vO-CU. +- vO-CU is connected to vO-DU. +- vO-CU is connected to 5GC through NG interface and vO-CU is operational. +- Support for PTP is enabled on all the Edge O-Cloud nodes. The Edge O-Cloud will host vO-DU as a service which will be operating as a slave clock. +- vO-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.67.4 Test Setup and Configuration + +- **DUTs:** SMO, vO-DU, vO-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.4. +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.67.5 Test Procedure + +The following table describes the test procedures to verify successful instantiation of a cloud-native Network Function as a new deployment on an O-Cloud. + +**Table 7.67-1: Successful vO-DU and vO-CU deployment.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|------------------------------------------------------------------------------------|-------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | O-Cloud Operator sends service request to instantiate new vO-DU on O-Cloud to SMO. | <b>O-Cloud Operator → SMO</b> | <p>Verify Service Request to SMO for the deployment is received with desired network function type set to vO-DU.</p> <p>Verify successful allocation of resources to the vO-DU on the O-Cloud.</p> <p>Verify initial SMO connectivity configuration such as O1 interface address and other security key information are injected into vO-DU.</p> <p>Verify SMO notifies O-Cloud operator the status of the successful instantiation of the vO-DU deployment.</p> | +| 2 | O-Cloud Operator sends service request to instantiate new vO-CU on O-Cloud to SMO. | <b>O-Cloud Operator → SMO</b> | <p>Verify Service Request to SMO for the deployment is received with desired network function type set to vO-CU.</p> <p>Verify successful allocation of resources to the vO-CU on the O-Cloud.</p> <p>Verify initial SMO connectivity configuration such as O1 interface address and other security key information are injected into vO-CU.</p> <p>Verify SMO notifies O-Cloud operator the status of the successful instantiation of the vO-CU deployment.</p> | +| 3 | SMO sends TLS secure connection establishment to vO-DU and vO-CU | <b>vO-DU ← SMO</b> | <p>Verify the TLS secure connection is established between SMO, vO-DU and vO-CU as per [22].</p> <p>SMO sends the NETCONF hello message to vO-DU and vO-CU</p> | + +| | | | | +|----|-----------------------------------------------------------------------------------------|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 4 | vO-DU sends cloudified NF Registration notification to SMO. | <b>vO-DU → SMO</b> | <p>Verify vO-DU sends the NETCONF capabilities supported to SMO in hello message.</p> <p>Verify vO-DU successfully sends o1NotifyCloudNFRegistration notification to SMO over HTTP/TLS after successfully completing instantiation.</p> <p>Verify vO-DU successfully subscribe to event/status from the O-Cloud.</p> | +| 5 | vO-CU sends cloudified NF Registration notification to SMO. | <b>vO-CU → SMO</b> | <p>Verify vO-CU sends the NETCONF capabilities supported to SMO in hello message.</p> <p>Verify vO-CU successfully sends o1NotifyCloudNFRegistration notification to SMO over HTTP/TLS after successfully completing instantiation.</p> | +| 6 | SMO sends cell configuration to vO-DU. | <b>vO-DU ← SMO</b> | Verify the cell configuration is received from SMO to vO-DU (O1 interface). | +| 7 | vO-DU sends Carrier configuration to O-RU to establish C/U-Plane application endpoints. | <b>O-RU ← vO-DU</b> | <p>Verify vO-DU sends the carrier configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE.</p> | +| 8 | O-RU sends Carrier configuration update Response to vO-DU. | <b>O-RU → vO-DU</b> | <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded, once the download is successful.</p> <p>Verify time synchronization using PTP is successful on O-RU and it sends sync-status as LOCKED to vO-DU.</p> | +| 9 | vO-DU sends sync-state information and set the operational state in SMO | <b>vO-DU → SMO</b> | <p>Verify vO-DU shall send the sync-state as LOCKED to SMO after receiving the synchronization notification using PTP pull.</p> <p>Verify vO-DU set the operational state to ENABLED.</p> | +| 10 | SMO shall set the administrative state of vO-DU. | <b>vO-DU ← SMO</b> | Verify vO-DU shall set the administrative state to UNLOCKED. | +| 11 | vO-DU sends an F1 SETUP REQUEST to establish connectivity between the vO-DU and vO-CU. | <b>vO-DU → vO-CU</b> | Verify vO-DU sends F1 SETUP REQUEST message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the vO-CU-CP (Control Unit) | +| 12 | vO-CU sends NGAP Setup Request to AMF. | <b>vO-CU → AMF</b> | Verify the NGAP Setup Request contains all the mandatory IEs mentioned in the section 9.2.6.1 of 3GPP Specification [20]. | +| 13 | vO-CU receives NGAP Setup Response from AMF. | <b>vO-CU ← AMF</b> | Verify AMF sends NGAP Setup Response message containing all the mandatory IEs mentioned in 9.2.6.1 of 3GPP Specification [20]. | +| 14 | vO-DU receives F1 SETUP RESPONSE from vO-CU. | <b>vO-DU ← vO-CU</b> | Verify vO-CU sends F1 SETUP RESPONSE message containing all the mandatory IEs mentioned in section 4.1.5.1.2 of ORAN.WG5.C.1 [19] to the vO-DU. | +| 15 | Cell Bring-up is initiated at vO-CU. | <b>vO-DU ← vO-CU</b> | vO-CU sends the F1AP gNB-CU configuration update to vO-DU. | + +| | | | | +|----|---------------------------------------------------------------------------|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>F1AP gNB-CU configuration update message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>vO-CU adds the cell information according to IE Served-Cells-To-Add-List.</p> | +| 16 | vO-DU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to vO-DU. | <b>vO-DU → vO-CU</b> | <p>Verify vO-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to vO-CU.</p> <p>F1AP gNB-CU configuration update Ack message contains all the mandatory IEs mentioned in section 4.1.6.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 17 | Activate the cell from the vO-DU. | <b>vO-DU → vO-CU</b> | <p>vO-DU sends the F1AP gNB-DU configuration update to O-CU.</p> <p>F1AP gNB-DU configuration update message contains all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> <p>vO-DU activates the cell information according to the service-state IE.</p> | +| 14 | vO-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to vO-CU. | <b>vO-DU ← vO-CU</b> | <p>Verify vO-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to vO-DU.</p> <p>F1AP gNB-DU configuration update Ack message contains all the mandatory IEs mentioned in section 4.1.6.1.2.4 of ORAN.WG5.C.1 [19].</p> | +| 15 | Verify the status of the cell. | <b>vO-DU/vO-CU</b> | <p>Verify SMO shows vO-CU and vO-DU operational and newly added cell is up and RF state of O-RU is ACTIVE.</p> <p>Verify O-RU sync-state is set to LOCKED state and available for CU-plane communication.</p> <p>vO-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> | +| 16 | Attach validation | <b>UE ← vO-DU/ vO-CU</b> | Verify that UE is able to attach successfully in cloudified deployment. | +| 17 | End to end data validation | <b>vO-DU/ vO-CU ↔ UPF</b> | Verify end to end data is successful. | + +## 7.68 ORAN.WG8.IOT.067: Verify successful addition of vO-DU and vO-CU instance when network demand increases beyond current NF capacity threshold. + +### 7.68.1 Test Purpose + +The purpose of this test case is to verify addition of vO-DU and vO-CU Network function instance when network demand increases beyond current NF capacity threshold. + +## 7.68.2 Reference Requirement + +For detailed requirements, refer to the section 8.3 and section 9.4 in ORAN-WG8.AAD [1]. + +## 7.68.3 Initial Conditions + +Following are the preconditions for this test. + +- SMO is configured to add an O-Cloud into its inventory prior to the O-Cloud itself being activated. +- O-Cloud ID is generated by the SMO which represents a globally unique identifier for identifying the new O-Cloud instance by the SMO. +- Physical network connectivity exists between the network gateway of O-Cloud and SMO. +- Cloud software installation on O-Cloud and O-Cloud nodes is successful and operational. +- O-RU is implemented as a physical Network Function and deployed remotely. O-RU is managed entirely by vO-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- Use the default vO-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in vO-CU. +- vO-CU is connected to vO-DU. +- vO-CU is connected to 5GC through NG interface and vO-CU is operational. +- Support for PTP is enabled on all the Edge O-Cloud nodes. The Edge O-Cloud will host vO-DU as a service which will be operating as a slave clock. +- vO-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-Cloud is available and vO-DU and vO-CU as a network function is successfully deployed. +- SMO has policies related to network function capacity modification (This is vendor specific, and the scale-out algorithms can vary depending on the implementation/design). + +## 7.68.4 Test Setup and Configuration + +- **DUTs:** SMO, vO-DU, vO-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + +- For details on the test setup refer Annex A - A.8. +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.68.5 Test Procedure + +The following table describes the test procedures to verify addition of vO-DU and vO-CU Network function when network demand increases beyond current NF capacity threshold. + +**Table 7.68-1: Addition of vO-DU and vO-CU instance.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------------------------------|---------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Multiple UE attach and bi-directional data traffic. | <b>UE <math>\leftarrow</math> vO-DU/ vO-CU <math>\leftrightarrow</math> UPF</b> | <p>Verify that multiple UEs are attached successfully in cloudified deployment.</p> <p>Verify end to end data is successful.</p> <p>Verify network resources are utilized beyond current capacity threshold.</p> | +| 2 | SMO triggers NF capacity modification processing. | <b>SMO <math>\rightarrow</math> O-Cloud</b> | <p>SMO determines that scale out is needed and determines what NF deployment scaling is required to increase vO-DU and vO-CU capacity.</p> <p>This is vendor specific, and the scale-out algorithm can vary depending on the implementation/design.</p> <p>Few examples for scale-out:</p> <ul style="list-style-type: none"> <li>• Due to high CPU utilization.</li> <li>• Due to high memory utilization.</li> <li>• UE based scaling.</li> </ul> <p>Note: As per section 3.2.2 of [32], scaling is managed by the SMO. Self-management of scaling by the NF is for future study.</p> | +| 3 | SMO sends TLS secure connection establishment to a newly added vO-DU and vO-CU | <b>vO-DU/ vO-CU <math>\leftarrow</math> SMO</b> | <p>Verify the TLS secure connection is established between SMO and vO-DU/vO-CU as per [22].</p> <p>SMO sends the NETCONF hello message to vO-DU and vO-CU</p> | +| 4 | vO-DU sends cloudified NF Registration notification to SMO. | <b>vO-DU <math>\rightarrow</math> SMO</b> | <p>Verify vO-DU sends the NETCONF capabilities supported to SMO in hello message.</p> <p>Verify vO-DU successfully sends o1NotifyCloudNFRegistration notification to SMO over HTTP/TLS after successfully completing instantiation.</p> <p>Verify vO-DU successfully subscribe to event/status from the O-Cloud.</p> | +| 5 | vO-CU sends cloudified NF Registration notification to SMO. | <b>vO-CU <math>\rightarrow</math> SMO</b> | <p>Verify vO-CU sends the NETCONF capabilities supported to SMO in hello message.</p> <p>Verify vO-CU successfully sends o1NotifyCloudNFRegistration notification to SMO over HTTP/TLS after successfully completing instantiation.</p> | + +| | | | | +|----|-----------------------------------------------------------------------------------------|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 6 | SMO sends cell configuration to vO-DU. | <b>vO-DU ← SMO</b> | Verify the cell configuration is received from SMO to vO-DU (O1 interface). | +| 7 | vO-DU sends Carrier configuration to O-RU to establish C/U-Plane application endpoints. | <b>O-RU ← vO-DU</b> | Verify vO-DU sends the carrier configuration through file download request.<br>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE. | +| 8 | O-RU sends Carrier configuration update Response to vO-DU. | <b>O-RU → vO-DU</b> | Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.<br>Verify time synchronization using PTP is successful on O-RU and it sends sync-status as LOCKED to vO-DU. | +| 9 | vO-DU sends sync-state information and set the operational state in SMO | <b>vO-DU → SMO</b> | Verify vO-DU shall send the sync-state as LOCKED to SMO after receiving the synchronization notification using PTP pull.<br><br>Verify vO-DU set the operational state to ENABLED. | +| 10 | SMO shall set the administrative state of vO-DU. | <b>vO-DU ← SMO</b> | Verify vO-DU shall set the administrative state to UNLOCKED. | +| 11 | Cell Bring-up | <b>vO-DU/vO-CU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>vO-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify vO-DU sets the administrative state to UNLOCKED state. | +| 12 | Verify the status of the cell. | <b>vO-DU/vO-CU</b> | Verify SMO shows vO-CU and vO-DU operational and newly added cell is up and RF state of O-RU is ACTIVE.<br><br>Verify O-RU sync-state is set to LOCKED state and available for CU-plane communication. | +| 13 | Attach validation | <b>UE ← vO-DU/ vO-CU</b> | Verify that UE is able to attach successfully in cloudified deployment. | +| 14 | End to end data validation | <b>vO-DU/ vO-CU ↔ UPF</b> | Verify end to end data is successful. | + +## 7.69 ORAN.WG8.IOT.068: Verify successful deletion of vO-DU and vO-CU instance when network demand reduces below NF capacity threshold. + +### 7.69.1 Test Purpose + +The purpose of this test case is to verify deletion of vO-DU and vO-CU Network function instance when network demand reduces below NF capacity threshold. + +## 7.69.2 Reference Requirement + +For detailed requirements, refer to the section 8.3 and section 9.4 in ORAN-WG8.AAD [1]. + +## 7.69.3 Initial Conditions + +Following are the preconditions for this test. + +- SMO is configured to add an O-Cloud into its inventory prior to the O-Cloud itself being activated. +- O-Cloud ID is generated by the SMO which represents a globally unique identifier for identifying the new O-Cloud instance by the SMO. +- Physical network connectivity exists between the network gateway of O-Cloud and SMO. +- Cloud software installation on O-Cloud and O-Cloud nodes is successful and operational. +- O-RU is implemented as a physical Network Function and deployed remotely. O-RU is managed entirely by vO-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- Use the default vO-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in vO-CU. +- vO-CU is connected to vO-DU. +- vO-CU is connected to 5GC through NG interface and vO-CU is operational. +- Support for PTP is enabled on all the Edge O-Cloud nodes. The Edge O-Cloud will host vO-DU as a service which will be operating as a slave clock. +- vO-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-Cloud is available and additional vO-DU as a network function is successfully deployed. +- SMO has policies related to network function capacity modification (This is vendor specific, and the scale-in algorithms can vary depending on the implementation/design). + +## 7.69.4 Test Setup and Configuration + +- **DUTs:** SMO, vO-DU, vO-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + +- For details on the test setup refer Annex A - A.8 +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.69.5 Test Procedure + +The following table describes the test procedures to verify deletion of vO-DU and vO-CU Network function instance when network demand reduces to below NF capacity threshold. + +**Table 7.69-1: Deletion of additional vO-DU and vO-CU instance.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|------------------------------------------------------------------------|--------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Multiple UE attach and bi-directional data traffic. | <b>UE ← vO-DU/ vO-CU ↔ UPF</b> | <p>Verify that multiple UEs are attached successfully in cloudified deployment.</p> <p>Verify end to end data is successful.</p> <p>Multiple instances of vO-DU and vO-CU are running due to NF scale-out.</p> <p>Some of the traffic is drained causing network function utilization to reduce below capacity threshold.</p> | +| 2 | SMO triggers NF capacity modification processing. | <b>SMO → O-Cloud</b> | <p>SMO determines that scale-in is needed.</p> <p>SMO prepares the vO-DU and vO-CU for deletion of an additional network function deployment unit from an O-Cloud resource Pool.</p> <p>This is vendor specific, and the scale-in algorithm can vary depending on the implementation/design.</p> <p>Note: As per section 3.2.2 of [32], scaling is managed by the SMO. Self-management of scaling by the NF is for future study.</p> | +| 3 | SMO sends requests to vO-DU and vO-CU with Deployment ID to terminate. | <b>vO-DU/ vO-CU ← SMO</b> | <p>Verify vO-DU and vO-CU gracefully initiates traffic removal and generates traffic drain notification towards SMO.</p> <p>Verify that vO-DU and vO-CU instance is successfully terminated from the O-Cloud resource pool.</p> <p>Verify that the existing NF is now able to handle the reduce demand in the network.</p> | +| 4 | Attach validation | <b>UE ← vO-DU/ vO-CU</b> | Verify that UE able to attach successfully with the existing NF deployment after scale-in. | +| 5 | End to end data validation | <b>O-DU/ O-CU ↔ UPF</b> | Verify end to end data is successful. | + +## 7.70 ORAN.WG8.IOT.069: Verify successful software upgrade for vO-DU. + +### 7.70.1 Test Purpose + +The purpose of this test case is to verify successful software upgrade for an vO-DU when a new software image is available and upgrade is initiated by SMO. + +### 7.70.2 Reference Requirement + +For detailed requirements, refer to the section 8.3 in ORAN-WG8.AAD [1]. + +### 7.70.3 Initial Conditions + +Following are the preconditions for this test. + +- SMO is configured to add an O-Cloud into its inventory prior to the O-Cloud itself being activated. +- O-Cloud ID is generated by the SMO which represents a globally unique identifier for identifying the new O-Cloud instance by the SMO. +- Physical network connectivity exists between the network gateway of O-Cloud and SMO. +- Cloud software installation on O-Cloud and O-Cloud nodes is successful and operational. +- O-RU is implemented as a physical Network Function and deployed remotely. O-RU is managed entirely by vO-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- Use the default vO-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in vO-CU. +- vO-CU is connected to vO-DU. +- vO-CU is connected to 5GC through NG interface and vO-CU is operational. +- Support for PTP is enabled on all the Edge O-Cloud nodes. The Edge O-Cloud will host vO-DU as a service which will be operating as a slave clock. +- vO-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-Cloud is available and vO-DU as a network function is successfully deployed. +- New software image is available in O-Cloud software image repository. + +### 7.70.4 Test Setup and Configuration + +- **DUTs:** SMO, vO-DU, vO-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. + +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.8. +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.70.5 Test Procedure + +The following table describes the test procedures to verify successful software upgrade for an vO-DU when a new software image is available and upgrade is initiated by SMO. + +**Table 7.70-1: Software upgrade of vO-DU.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------------------------------------------------|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO configures new vO-DU instance when a new software version is available. | <b>SMO<br/>→<br/>vO-DU</b> | Verify SMO configures new instance of vO-DU with an upgraded version into the O-Cloud resource pool. | +| 2 | SMO sends TLS secure connection establishment to the new instance of vO-DU. | <b>vO-DU ←<br/>SMO</b> | Verify the TLS secure connection is established between SMO and the new instance of vO-DU as per [22].<br><br>SMO sends the NETCONF hello message to the new instance of vO-DU. | +| 3 | New instance of vO-DU sends cloudified NF Registration notification to SMO. | <b>vO-DU →<br/>SMO</b> | Verify new instance of vO-DU sends the NETCONF capabilities supported to SMO in hello message.<br><br>Verify new instance of vO-DU successfully sends o1NotifyCloudNFRegistration notification to SMO over HTTP/TLS after successfully completing instantiation.<br><br>Verify new instance of vO-DU successfully subscribe to event/status from the O-Cloud. | +| 4 | SMO sends cell configuration to new instance of vO-DU. | <b>vO-DU ←<br/>SMO</b> | Verify the cell configuration is received from SMO to new instance of vO-DU (O1 interface). | +| 5 | New instance of vO-DU sends Carrier configuration to O-RU to establish C/U-Plane application. | <b>O-RU ← vO-DU</b> | Verify new instance of vO-DU sends the carrier configuration through file download request.<br>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE. | +| 6 | O-RU sends Carrier configuration update Response to the new instance of vO-DU. | <b>O-RU → vO-DU</b> | Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.<br>Verify time synchronization using PTP is successful on O-RU and it sends sync-status as LOCKED. | + +| | | | | +|----|-----------------------------------------------------------------------------------------|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 7 | New instance of vO-DU sends sync-state information and set the operational state in SMO | <b>vO-DU → SMO</b> | Verify new instance of vO-DU shall send the sync-state as LOCKED to SMO after receiving the synchronization notification using PTP pull.<br><br>Verify new instance of vO-DU set the operational state to ENABLED. | +| 8 | SMO shall set the administrative state of new instance of vO-DU. | <b>vO-DU ← SMO</b> | Verify new instance of vO-DU shall set the administrative state to UNLOCKED. | +| 9 | Cell Bring-up | <b>vO-DU/vO-CU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>vO-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify new instance of vO-DU sets the administrative state to UNLOCKED state. | +| 10 | Verify the status of the cell. | <b>vO-DU/vO-CU</b> | Verify SMO shows vO-CU and new instance of vO-DU operational and newly added cell is up and RF state of O-RU is ACTIVE.<br><br>Verify O-RU sync-state is set to LOCKED state and available for CU-plane communication. | +| 11 | Attach validation | <b>UE ← vO-DU/ vO-CU</b> | Verify that UE able to attach successfully with above mentioned configuration. | +| 12 | End to end data validation | <b>vO-DU/ vO-CU ↔ UPF</b> | Verify end to end data is successful. | +| 13 | SMO triggers removal of the vO-DU running with older software version. | <b>SMO → vO-DU</b> | Verify successful addition of a new instance of vO-DU with upgraded software version is functional.<br><br>SMO prepares the vO-DU with older software version for deletion after traffic drain complete notification is received from the NF instance. | +| 14 | SMO sends requests to vO-DU with Deployment ID to terminate. | <b>vO-DU ← SMO</b> | Verify that vO-DU with older software version instance is successfully terminated from the O-Cloud resource pool. | + +## 7.71 ORAN.WG8.IOT.070: Verify successful reconfiguration for vO-DU. + +### 7.71.1 Test Purpose + +The purpose of this test case is to verify successful reconfiguration for an vO-DU when SMO performs configuration updates in RAN over O1 interface. + +### 7.71.2 Reference Requirement + +For detailed requirements, refer to the section 8.3 in ORAN-WG8.AAD [1]. + +### 7.71.3 Initial Conditions + +Following are the preconditions for this test. + +- SMO is configured to add an O-Cloud into its inventory prior to the O-Cloud itself being activated. +- O-Cloud ID is generated by the SMO which represents a globally unique identifier for identifying the new O-Cloud instance by the SMO. +- Physical network connectivity exists between the network gateway of O-Cloud and SMO. +- Cloud software installation on O-Cloud and O-Cloud nodes is successful and operational. +- O-RU is implemented as a physical Network Function and deployed remotely. O-RU is managed entirely by vO-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- Use the default vO-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in vO-CU. +- vO-CU is connected to vO-DU. +- vO-CU is connected to 5GC through NG interface and vO-CU is operational. +- Support for PTP is enabled on all the Edge O-Cloud nodes. The Edge O-Cloud will host vO-DU as a service which will be operating as a slave clock. +- vO-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-Cloud is available and vO-DU as a network function is successfully deployed. + +### 7.71.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, vO-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.8. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.71.5 Test Procedure + +The following table describes the test procedures to verify vO-DU successfully downloads the configuration from SMO. + +**Table 7.71-1: Successful reconfiguration for an vO-DU over O1 interface** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------|------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Multiple UE attach and bi-directional data traffic. | <b>UE ← vO-DU/ vO-CU<br/>↔ UPF</b> | Verify that multiple UEs are attached successfully in cloudified deployment.<br><br>Verify end to end data is successful. | +| 2 | vO-DU sends PM Data File ready notification to SMO. | <b>vO-DU → SMO</b> | Verify vO-DU sends notifyFileReady notification towards SMO as mentioned in [22] with the correct PM File Content and naming as mentioned in [28].<br><br>SMO successfully receives the Performance Measurements file.<br><br>SMO can use it for parameter optimization and reconfiguration of parameters on O1 interface. | +| 3 | Optimal beamforming configuration Ready at SMO. | <b>vO-DU ← SMO</b> | Verify SMO sends notifyFileReady notification towards vO-DU as mentioned in [22] with new beamforming configuration. | +| 4 | File download requested by SMO. | <b>vO-DU ← SMO</b> | Verify SMO sends "file-download-request" to trigger file download from server by vO-DU, including the location of the file. | +| 5 | File download accepted by vO-DU. | <b>vO-DU → SMO</b> | Verify vO-DU sends a "downloadFile" notification to SMO with final status of the download as success. | +| 6 | File download at O-RU. | <b>O-RU ← vO-DU</b> | Verify O-RU Controller/vO-DU sends file-download request to O-RU including the location of the file as mentioned in [24]. | +| 7 | File downloaded at O-RU. | <b>O-RU → vO-DU</b> | Verify O-RU sends response towards O-RU Controller/vO-DU with status of the file-download request as accepted.<br><br>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful. | +| 8 | De-activate tx-array-carriers and rx-array-carriers | <b>O-RU ← vO-DU</b> | Verify the NETCONF client/vO-DU shall deactivate tx-array-carriers and rx-array-carriers in the U-Plane configuration by setting "INACTIVE" for the active parameters if they are ACTIVE. | +| 9 | De-activate the cell from the vO-DU. | <b>vO-DU → vO-CU</b> | vO-DU sends the F1AP gNB-DU configuration update to vO-CU.<br><br>F1AP gNB-DU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.5 of ORAN.WG5.C.1 [19].<br><br>O-DU should de-activate the cell information according to the service-state IE. | +| 10 | Apply new edited beamforming information | <b>O-RU ← vO-DU</b> | Verify vO-DU updated the new edited beamforming config to O-RU as per o-ran-beamforming.yang as mentioned in [24]. | + +| | | | | +|----|-------------------------------------------------------------------------------------|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 11 | Activate the cell from the vO-DU. | <b>vO-DU → vO-CU</b> | <p>vO-DU sends the F1AP gNB-DU configuration update to vO-CU.</p> <p>F1AP gNB-DU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.5 of ORAN.WG5.C.1 [19].</p> <p>O-DU should de-activate the cell information according to the service-state IE.</p> | +| 12 | Activate tx-array-carriers and rx-array-carriers with new beamforming configuration | <b>O-RU ← vO-DU</b> | Verify the NETCONF client/vO-DU shall activate tx-array-carriers and rx-array-carriers in the U-Plane configuration by setting "ACTIVE" for the in-active parameters. | +| 13 | Cell bring-up | <b>vO-DU/O-RU</b> | Verify cell bring-up is successful with the optimized beamforming configuration that has been received from SMO. | +| 14 | Attach validation | <b>UE ↔ vO-DU/vO-CU</b> | Verify that UE able to attach successfully. | +| 15 | End to end data validation | <b>vO-DU/ vO-CU ↔ UPF</b> | Verify end to end data is successful. | + +## 7.72 ORAN.WG8.IOT.071: Verify vO-DU functionality during PTP sync loss and recovery. + +### 7.72.1 Test Purpose + +The purpose of this test case is to verify vO-DU functionality during PTP sync loss and recovery. + +### 7.72.2 Reference Requirement + +For detailed requirements, refer to the section 7.11 in ORAN-WG8.AAD [1]. + +### 7.72.3 Initial Conditions + +Following are the preconditions for this test. + +- SMO is configured to add an O-Cloud into its inventory prior to the O-Cloud itself being activated. +- O-Cloud ID is generated by the SMO which represents a globally unique identifier for identifying the new O-Cloud instance by the SMO. +- Physical network connectivity exists between the network gateway of O-Cloud and SMO. +- Cloud software installation on O-Cloud and O-Cloud nodes is successful and operational. +- O-RU is implemented as a physical Network Function and deployed remotely. O-RU is managed entirely by vO-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- Use the default vO-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in vO-CU. + +- vO-CU is connected to vO-DU. +- vO-CU is connected to 5GC through NG interface and vO-CU is operational. +- Support for PTP is enabled on all the Edge O-Cloud nodes. The Edge O-Cloud will host vO-DU as a service which will be operating as a slave clock. +- vO-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-Cloud is available and vO-DU as a network function is successfully deployed. +- vO-DU has successfully subscribed to event/status from the O-Cloud and vO-DU is time synchronized. + +## 7.72.4 Test Setup and Configuration + +- **DUTs:** SMO, vO-DU, vO-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.8. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.72.5 Test Procedure + +The following table describes the test procedures to verify vO-DU functionality during PTP sync loss and recovery. + +**Table 7.72-1: PTP sync loss & recovery in vO-DU.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------------------------------------------------------------------------------------------------------|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | O-Cloud triggers event notification when synchronizing network delivers unacceptable synchronization quality. | <b>O-Cloud → vO-DU</b> | Verify vO-DU receives PTP synchronization state notification with value set to "HOLDOVER"<br><br>Verify vO-DU transits to the HOLDOVER state.<br><br>Verify vO-DU shall send the sync-state as HOLDOVER to SMO. | +| 2 | Verify the status of the cell. | <b>vO-DU/vO-CU</b> | Verify SMO shows vO-CU and vO-DU operational and RF state of O-RU is ACTIVE. | + +| | | | | +|----|-------------------------------------------------------------------------------------------------------------|--------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3 | Holdover mode expires at O-Cloud. | <b>O-Cloud → vO-DU</b> | Verify vO-DU receives PTP synchronization state notification with value set to “FREERUN”<br><br>Verify vO-DU transits to the FREERUN state. | +| 4 | Verify the status of the cell. | <b>vO-DU → SMO</b> | Verify vO-DU shall send the sync-state as FREERUN to SMO.<br><br>vO-DU shall disable RF transmission on all connected O-RUs, and keep it turned off until synchronization is recovered. | +| 5 | vO-DU sends the gNB-DU CONFIGURATION UPDATE message to vO-CU | <b>vO-DU → vO-CU</b> | Verify vO-DU sends the gNB-CU CONFIGURATION UPDATE ACKNOWLEDGE message to vO-CU.<br><br>Verify that as vO-DU sync state was not locked, it shall not activate any cells from Cells to be Activated List Item IE.<br><br>Verify that vO-DU shall report back to vO-CU Cells failed to be activated list IE.<br><br>vO-DU should send the cell information according to the service-state IE i.e. Out-Of-Service. | +| 6 | vO-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to vO-DU | <b>vO-DU ← vO-CU</b> | Verify vO-CU sends the gNB-DU CONFIGURATION UPDATE ACKNOWLEDGE message to vO-DU. | +| 7 | O-Cloud triggers event notification when synchronizing network delivers acceptable synchronization quality. | <b>O-Cloud → vO-DU</b> | Verify vO-DU receives PTP synchronization state notification with value set to “LOCKED”<br><br>Verify time synchronization using PTP is successful on O-RU and it sends sync-status as LOCKED to vO-DU.<br><br>Verify vO-DU shall send the sync-state as LOCKED to SMO. | +| 8 | SMO shall set the administrative state of vO-DU. | <b>vO-DU ← SMO</b> | Verify vO-DU shall set the administrative state to UNLOCKED. | +| 10 | Cell Bring-up | <b>vO-DU/vO-CU</b> | Verify vO-DU sets the administrative state to UNLOCKED state.<br><br>Verify cell bring-up is successful.<br><br>vO-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24]. | +| 11 | Verify the status of the cell. | <b>vO-DU/vO-CU</b> | Verify SMO shows vO-CU and vO-DU operational and RF state of O-RU is ACTIVE.<br><br>Verify O-RU sync-state is set to LOCKED state and available for CU-plane communication. | +| 12 | Attach validation. | <b>UE ← vO-DU/ vO-CU</b> | Verify that UE able to attach successfully. | + +| | | | | +|----|-----------------------------|--------------------|---------------------------------------| +| 13 | End to end data validation. | vO-DU/ vO-CU ↔ UPF | Verify end to end data is successful. | +|----|-----------------------------|--------------------|---------------------------------------| + +## 7.73 ORAN.WG8.IOT.072: Verification of SSH/ TLS version compatibility of secured NETCONF session creation at O1 interface and fronthaul interface. + +### 7.73.1 Test Purpose + +The purpose of this test case is to verify the version compatibility of SSH or TLS channel during NETCONF sessions establishment between O-DU server and SMO client at O1 interface and O-DU client and O-RU server at fronthaul M-Plane interface. + +### 7.73.2 Reference Requirement + +For detailed requirements, refer to the section 8.4 in ORAN-WG8.AAD [1]. + +### 7.73.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU are connected. +- SMO, O-DU client, O-DU server, and O-RU server have obtained their IPv4 addresses by auto-configuration with DHCP IPv4 or IPv6 address allocation. +- Default X.509 certificates are exchanged between SMO and O-DU, O-DU and O-RU by negotiating the key exchange algorithm between the client and server as described in O-RAN WG11 Security Protocol Specification [34] section 4. Public key certificates are used for authentication, secured data encryption and decryption. +- O-DU server has obtained the SMO client IP address, and O-RU server has obtained the O-DU client IP address through DHCP routing information or static routing configuration. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. Connecting CU-Plane for data and the M-Plane for O-RU configuration updates. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.73.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario: +- Test UEs or UE emulator which can support NR. + +- 5G-NR O-RU or O-RU emulator. +- 5G-NR SMO. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A – A.4. + +## 7.73.5 Test Procedure + +The following table describes the test procedure to verify SSH/ TLS version compatibility for the established NETCONF sessions between SMO client and O-DU server at O1 interface and O-DU client to O-RU server at fronthaul M-Plane interface. + +**Table 7.73-1: SSH/ TLS version compatibility verification during NETCONF session creation at O1 interface and fronthaul interface** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|--------------------------------------------------------------|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Bring up O-DU. | <b>SMO ← O-DU</b> | <p>Verify O-DU is powered ON and obtains its client and server IP addresses.</p> <p>Verify O-DU server sends Pnfregistration message to SMO IP address with all the mandatory information elements.</p> | +| 2 | SMO sends TLS connection initiation request to O-DU. | <b>O-DU ← SMO</b> | <p>Verify SMO sends TLS client hello message to O-DU with all the mandatory parameters.</p> <p>O-DU verifies the version information from the client hello message with that of the supported version at the O-DU server. TLS version between client and server supports version 1.2 mandatorily or 1.3 optionally, otherwise the connection is denied as per section 4.2 of [34].</p> <p>Verify O-DU initiates authentication process and confirms to client about the TLS version compatibility by sending server hello message.</p> | +| 3 | NETCONF session establishment between SMO and O-DU | <b>SMO / O-DU</b> | Verify NETCONF hello capability messages are communicated between SMO client and O-DU server to establish successful NETCONF session at O1 interface. | +| 4 | O-DU sends SSH or TLS connection initiation request to O-RU. | <b>O-DU → O-RU</b> | <p>Verify O-DU sends SSH connection initiate message or TLS client hello message to O-RU with all the mandatory parameters.</p> <p>O-RU verifies the version information from the SSH initiate message with that of the supported version at the O-RU server. The SSH version between client and server should support version 2 mandatorily, otherwise the connection is denied, as per section 4.1 of [34].</p> <p>Alternatively, O-RU verifies the version information from the TLS client hello message with that of the supported version at the O-RU server. The TLS version between client and server should support 1.2 mandatorily or 1.3 optionally, otherwise the connection is denied as per section 4.2 of [34].</p> <p>Verify O-RU initiates authentication process by confirming to the client about the SSH or TLS version compatibility to establish secured connection.</p> | +| 5 | NETCONF session establishment between O-DU and O-RU | <b>O-DU / O-RU</b> | Verify NETCONF hello capability messages are communicated between O-DU client and O-RU server to establish successful NETCONF session at fronthaul interface. | + +## 7.74 ORAN.WG8.IOT.073: Verification of successful secured NETCONF session creation over SSH/ TLS channel at the O1 interface and fronthaul interface. + +### 7.74.1 Test Purpose + +The purpose of this test case is to verify successful secured NETCONF session creation using SSH or TLS channel between O-DU server and SMO client at O1 interface and O-DU client and O-RU server at fronthaul M-Plane interface. + +### 7.74.2 Reference Requirement + +For detailed requirements, refer to the section 8.4 in ORAN-WG8.AAD [1]. + +### 7.74.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU are connected. +- SMO, O-DU client, O-DU server and O-RU server have obtained their IPv4 addresses by auto-configuration with DHCP IPv4 or IPv6 address allocation. +- Default X.509 certificates are exchanged between SMO and O-DU, O-DU and O-RU by negotiating the key exchange algorithm as described in O-RAN WG11 Security Protocol Specification [34] section 4. Public key certificates are used for deriving username of client by the server or vice versa, authentication, secured data encryption and decryption. +- O-DU server has obtained SMO IP address, and O-RU server has obtained O-DU client IP address through DHCP routing information or static routing configuration. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. Connecting CU-Plane for data and the M-Plane for O-RU configuration transfer. +- SMO, O-DU and O-RU supports SSHV2 and TLS 1.2 mandatorily, or TLS 1.3 optionally, for the NETCONF connection, as defined by O-RAN WG11 security protocol specification [34]. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- O-DU is connected with M-Plane O-RU with Ethernet cable. +- + +### 7.74.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario: + +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G-NR SMO. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A – A.4. + +## 7.74.5 Test Procedure + +The following table describes the test procedures to verify secured NETCONF session creation over SSH or TLS channel established between SMO and O-DU at O1 interface and O-DU and O-RU at fronthaul M-Plane interface. + +**Table 7.74-1: Verification of secured NETCONF session creation over SSH or TLS channel at O1 interface and fronthaul interface** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|---------------------------------------------------------------------------------------------------------------------------|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Bring up O-DU. | <b>SMO ← O-DU</b> | <p>Verify O-DU is powered ON and obtains its client and server IP addresses.</p> <p>Verify O-DU server sends Pnfregristration message to SMO IP address with all the mandatory information elements.</p> | +| 2 | SMO (TLS client) and O-DU (TLS server) authenticate each other to establish TLS secured connection. | <b>SMO / O-DU</b> | <p>Verify SMO sends TLS client hello message to O-DU with all the mandatory parameters, once verifying the authentication of the server from the list of known hosts available at the client.</p> <p>Verify O-DU authenticates SMO using mutual public key-based client and server authentication method using X.509 certificates, as per section 3.4.2 of [22].</p> | +| 3 | Secured NETCONF session establishment between SMO and O-DU. | <b>O-DU / SMO</b> | <p>SMO and O-DU negotiate ciphering algorithm and integrity MACs algorithm using the supported cypher suits, as per section 4.2.2 of [34]. This ensures a secured TLS channel at O1 interface.</p> <p>Verify NETCONF hello capability messages are communicated between SMO and O-DU to establish successful NETCONF session at O1 interface.</p> | +| 4 | O-RU initiates NETCONF call home procedure with O-DU. | <b>O-DU ← O-RU</b> | <p>Verify O-RU sends TCP connection request to O-DU as part of call home procedure to establish NETCONF session.</p> | +| 5 | O-DU (SSH or TLS client) and O-RU (SSH or TLS server) authenticate each other to establish SSH or TLS secured connection. | <b>O-DU / O-RU</b> | <p>Verify O-DU sends SSH connection initiate message or TLS client hello message to O-RU with all the mandatory parameters, once verifying the authentication of the server from the list of known hosts available at the client.</p> <p>O-RU authenticates O-DU using password-based authentication method or public key-based client authentication method using X.509 certificates in case of SSHv2, as per section 6.4.2 of [24].</p> <p>Alternatively, O-RU authenticates O-DU using mutual public key-based client authentication method using X.509 certificates in case of TLS 1.2 or 1.3, as per section 6.4.2 of [24].</p> | +| 6 | Secured NETCONF session establishment between O-DU and O-RU. | <b>O-RU / O-DU</b> | <p>O-RU and O-DU negotiate ciphering algorithm and integrity MAC generation algorithm using the supported cypher suits, as per section 4.1.2.1 for SSH or 4.2.2 for TLS of [34]. This ensures a secured SSH or TLS channel at fronthaul interface.</p> <p>Verify NETCONF hello capability messages are communicated between O-DU and O-RU to establish successful NETCONF session at fronthaul interface.</p> | + +| | | | | +|----|----------------------------------------------------------------------|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 7 | C/U plane transport connectivity verification between O-DU and O-RU. | <b>O-RU / O-DU</b> | <p>O-DU sends loopback message to O-RU with MAC address and vlan-id periodically</p> <p>O-RU sends loopback response to O-DU per received loopback message respectively</p> <p>Based on the LBM responses received the O-DU shall decide on the connectivity status</p> | +| 8 | Cell Bring-up | <b>O-DU/O-CU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify new instance of O-DU sets the administrative state to UNLOCKED state.</p> | +| 9 | Verify the status of the cell. | <b>O-DU/O-CU</b> | <p>Verify SMO shows O-CU and new instance of O-DU operational and newly added cell is up and RF state of O-RU is ACTIVE.</p> <p>Verify O-RU sync-state is set to LOCKED state and available for CU-plane communication.</p> | +| 10 | Attach validation | <b>UE ← O-DU/ O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration. | +| 11 | End to end data validation | <b>O-DU/ O-CU<br/>↔ UPF</b> | Verify end to end data is successful. | + +## 7.75 ORAN.WG8.IOT.074: Verification of Access Control Groups defined for NETCONF sessions created at O1 interface and fronthaul interface. + +### 7.75.1 Test Purpose + +The purpose of this test case is to verify the access control group privileges that are provided for the NETCONF sessions between SMO client and O-DU server at the O1 interface and between O-DU client and O-RU server at the fronthaul M-Plane interface. + +## 7.75.2 Reference Requirement + +For detailed requirements, refer to the section 8.4 in ORAN-WG8.AAD [1]. + +## 7.75.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU are connected. +- SMO, O-DU client, O-DU server and O-RU server have obtained their IPv4 addresses by auto-configuration with DHCP IPv4 or IPv6 address allocation. +- Default X.509 certificates are exchanged between SMO and O-DU, O-DU and O-RU by negotiating the key exchange algorithm as described in O-RAN WG11 Security Protocol Specification [34] section 4. Public key certificates are used for deriving username of client by the server or vice versa, authentication, secured data encryption and decryption. +- O-DU server has obtained SMO IP address, and O-RU server has obtained O-DU client IP address through DHCP routing information or static routing configuration. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. Connecting CU-Plane for data and the M-Plane for O-RU configuration transfer. +- SMO, O-DU and O-RU supports SSHV2 and TLS 1.2 mandatorily, or TLS 1.3 optionally, for the NETCONF connection, as defined by O-RAN WG11 security protocol specification [34]. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.75.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU. +- **Testing tools:** are required for this test scenario: +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G-NR SMO. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + +- For details on the test setup refer Annex A - A.4. + +## 7.75.5 Test Procedure + +The following table describes the test procedures to verify the access control group privilege configuration that is set during NETCONF session establishment at O1 interface and fronthaul interface. + +**Table 7.75-1: Access control group verification for NETCONF session establishment at O1 interface and fronthaul interface** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------|----------|-----------------| +|-----|-----------|----------|-----------------| + +| | | | | +|---|-----------------------------------------------------|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Bring up O-DU. | <b>SMO ← O-DU</b> | <p>Verify O-DU is powered on and obtained its client and server IP address.</p> <p>Verify O-DU server sends Pnfregistration message to SMO IP address with all the mandatory IEs incorporated.</p> | +| 2 | NETCONF session establishment between SMO and O-DU. | <b>O-DU / SMO</b> | <p>Verify NETCONF session is successful to establish O1 interface between SMO client and O-DU server.</p> <p>If TLS is enabled, O-DU authenticates SMO (TLS client) to establish a secured NETCONF session based on the certificates available at O-DU.</p> <p>Verify SMO is given “SUDO” privileges to provide full access like read, write and execute options according to the NETCONF access control group configuration as per section 5.5 of [22].</p> | +| 3 | SMO sends cell configuration to O-DU. | <b>SMO → O-DU</b> | <p>Verify SMO sends cell configurations with all the mandatory IEs.</p> <p>O-DU verifies the NETCONF access control group privilege of the requested SMO using the SMO’s username available at O-DU and executes the configuration update based on “SUDO” privileges, as per section 5.5 of [22].</p> | +| 4 | NETCONF session establishment between O-DU and O-RU | <b>O-RU / O-DU</b> | <p>Verify NETCONF session is successful for the fronthaul M-Plane interface between O-DU and O-RU.</p> <p>Either for SSH or TLS, O-RU authenticates O-DU (SSH/ TLS client) to establish a secured NETCONF session based on the certificates available at O-RU.</p> <p>Verify O-DU is given “SUDO” privileges to provide full access like read, write and execute options according to the NETCONF access control group configuration as per section 6.5 of [24].</p> | +| 5 | O-DU sends cell configuration to O-RU. | <b>SMO → O-DU</b> | <p>Verify O-DU sends cell configurations with all the mandatory IEs related to low PHY parameters of the cell.</p> <p>O-RU verifies the NETCONF access group privilege of the requested O-DU using the O-DU’s username available at O-RU and executes the configuration update based on “SUDO” privileges, as per section 6.5 of [24].</p> | + +## 7.76 ORAN.WG8.IOT.075: Verify cell bring up using GoB configuration received from SMO is successful. + +### 7.76.1 Test Purpose + +The purpose of this test case is to verify cell bring up using GoB configuration received from SMO is successful. + +## 7.76.2 Reference Requirement + +For detailed requirements, refer to the section 7.14 and section 13.1 in ORAN-WG8.AAD [1]. + +## 7.76.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU supports static or vendor specific GoB configuration. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.76.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.76.5 Test Procedure + +The following table describes the test procedures to verify cell bring up using GoB configuration received from SMO is successful. + +**Table 7.76-1: Cell bring up with GoB configuration** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|----------------------------------------------------------------------------|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming received from SMO to O-DU. | <b>O-DU ← SMO</b> | <p>Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:</p> <p>Beamforming configuration:</p> <ul style="list-style-type: none"> <li>• ssb-PositionsInBurst <ul style="list-style-type: none"> <li>◦ groupPresence = 11111111</li> <li>◦ inOneGroup = 11111111</li> </ul> </li> <li>• ssb-periodicityServingCell</li> <li>• subCarrierSpacingCommon</li> <li>• ssb-SubcarrierOffset</li> <li>• numTxAnt</li> <li>• numRxAnt</li> <li>• numofBeams</li> <li>• numTXRUs</li> <li>• beamIndex</li> <li>• beamType</li> <li>• beamAzimuth</li> <li>• beamTilt</li> <li>• beamHorizWidth</li> <li>• beamVertWidth</li> <li>• coverageShape</li> <li>• digitalTilt</li> <li>• digitalAzimuth</li> <li>• numAntPorts (64)</li> <li>• numLayers</li> </ul> | +| 2 | Cell configuration with beamforming information received from O-DU to O-RU | <b>O-RU ← O-DU</b> | <p>Verify O-DU sends the beamforming configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE.</p> | +| 3 | Cell configuration update Response received from O-RU to O-DU. | <b>O-RU → O-DU</b> | <p>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.</p> <p>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE.</p> | +| 4 | Cell bring-up. | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | + +| | | | | +|---|-----------------------------------------------------------|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 5 | O-DU/O-RU broadcast SSB beams as per defined periodicity. | <b>UE ← O-DU/<br/>O-CU</b> | Verify the O-RU transmit all the 8 beams with a periodicity of 20ms.<br>Verify UE selects the strongest SSB beam from 8 beams broadcasted and sends RACH request with PRACH config index corresponding to beam selected. | +| 6 | Attach validation. | <b>UE ← O-DU/<br/>O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration | +| 7 | End to end data validation. | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify end to end data is successful. | + +## 7.77 ORAN.WG8.IOT.076: Verify successful AI/ML-assisted non-GoB beamforming optimization in Near RT RIC. + +### 7.77.1 Test Purpose + +The purpose of this test case is to verify successful collection of L1 measurements and transfer of AI/ML assisted non-GoB beamforming optimization on E2 interface. + +### 7.77.2 Reference Requirement + +For detailed requirements, refer to the section 7.14 and section 13.1 in ORAN-WG8.AAD [1]. + +### 7.77.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- O-DU supports Non-GoB Beamforming. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. + +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.77.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.77.5 Test Procedure + +The following table describes the test procedures to verify successful collection of L1 measurements and transfer of AI/ML assisted non-GoB beamforming optimization on E2 interface. + +**Table 7.77-1: AI/ML assisted non-GoB beamforming optimization on E2 interface.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|----------------------------------------------------------------|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell configuration with beamforming received from SMO to O-DU. | <b>O-DU ← SMO</b> | Verify the following configuration is received from SMO to O-DU-OAM-Agent (O1 interface) and O-DU-OAM-Agent to MAC:<br><br>Beamforming configuration: <ul style="list-style-type: none"> <li>• ssb-PositionsInBurst <ul style="list-style-type: none"> <li>◦ groupPresence = 11111111</li> <li>◦ inOneGroup =11111111</li> </ul> </li> <li>• ssb-periodicityServingCell</li> <li>• subCarrierSpacingCommon</li> <li>• ssb-SubcarrierOffset (0-11)</li> <li>• numTxAnt</li> <li>• numRxAnt</li> <li>• numofBeams (64)</li> <li>• numTXRUs (64)</li> <li>• beamIndex (64)</li> </ul> | + +| | | | | +|---|-----------------------------------------------------------------------------|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <ul style="list-style-type: none"> <li>beamType</li> <li>beamAzimuth</li> <li>beamTilt</li> <li>beamHorizWidth</li> <li>beamVertWidth</li> <li>coverageShape</li> <li>digitalTilt</li> <li>digitalAzimuth</li> <li>numAntPorts (64)</li> <li>numLayers</li> </ul> | +| 2 | Cell configuration with beamforming information received from O-DU to O-RU. | <b>O-RU ← O-DU</b> | Verify O-DU sends the beamforming configuration through file download request.<br>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE. | +| 3 | Cell configuration update Response received from O-RU to O-DU. | <b>O-RU → O-DU</b> | Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful.<br>Verify once the O-RU applies new configuration, the state of O-RU is changed to ACTIVE. | +| 4 | O-DU sends the E2 Setup request to near RT-RIC server. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the E2 Setup request message to near RT-RIC server with all the mandatory IEs. | +| 5 | near RT-RIC server sends E2 Setup Response to O-DU. | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC sends the E2 setup response to O-DU with all the mandatory IEs. | +| 6 | Cell bring-up | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify O-DU sets the administrative state to UNLOCKED state. | +| 7 | O-DU/O-RU broadcast SSB beams as per defined periodicity. | <b>UE ← O-RU ← O-DU</b> | Verify the O-RU transmit all the 8 beams with a periodicity of 20ms.<br>Verify UE selects the strongest SSB beam from 8 beams broadcasted and sends RACH request with PRACH config index corresponding to beam selected. | +| 8 | Near RT-RIC sends E2 RIC Query Request to O-DU | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC sends E2 RIC Control Request to O-DU with following IEs: <ul style="list-style-type: none"> <li>Message Type</li> <li>RIC Request ID</li> <li>RAN Function ID</li> <li>RIC Query Header <ul style="list-style-type: none"> <li>RIC Style Type (2 = UE Information Query)</li> </ul> </li> <li>RIC Query Definition <ul style="list-style-type: none"> <li>List of RAN parameters (2)</li> <li>RAN Parameter ID</li> <li>RAN Parameter Value (Number of supported Non-GoB beamforming modes )</li> </ul> </li> </ul> | + +| | | | | +|----|--------------------------------------------------------------------------------------------------------------------------|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 9 | O-DU sends E2 RIC Query Response to Near RT-RIC | <b>O-DU → near RT-RIC</b> | Verify O-DU sends E2 RIC Query Response to Near RT-RIC with following IEs: <ul style="list-style-type: none"> <li>• Message Type</li> <li>• RIC Request ID</li> <li>• RAN Function ID</li> <li>• RIC Query Outcome <ul style="list-style-type: none"> <li>○ UE ID</li> <li>○ List of RAN parameters</li> <li>○ RAN Parameter ID (2)</li> <li>○ RAN Parameter Value</li> <li>○ Non-GoB Beamforming Mode Index (A vendor-specific proprietary Non-GoB BF algorithm)</li> </ul> </li> </ul> | +| 10 | Attach validation | <b>UE ← O-DU/O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration | +| 11 | End to end data validation | <b>O-DU/O-CU → UPF</b> | Verify end to end data is successful. | +| 12 | near RT-RIC sends E2 Subscription Request to O-DU. | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC server sends E2 Subscription Request to O-DU with the below measurements mentioned in RIC Action Definition IE, Section 5 of 3GPP Specification [25]: <ul style="list-style-type: none"> <li>• L1-RSRP measurement per UE</li> <li>• L1-SINR measurement per UE</li> <li>• CSI-RS Resource Indicator (CRI)</li> <li>• SS/PBCH Block Resource Indicator (SSBRI) per UE</li> </ul> | +| 13 | O-DU sends the E2 Subscription Response to near-RT RIC server with supported subscription items and not supported items. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the E2 Subscription Response to near-RT-RIC server with “RIC Actions Admitted List” IE filled with O-DU supported list from the SUBSCRIPTION REQUEST and “RIC Actions Not Admitted List” IE filled with O-DU non-supported list. | +| 14 | O-DU sends the periodic report to the subscribed features to near RT-RIC server through RIC INDICATION message. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the periodic report to near RT-RIC server through RIC INDICATION message as per SUBSCRIPTION REQUEST. | +| 15 | Near RT-RIC sends E2 RIC Control Request to O-DU | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC sends E2 RIC Control Request to O-DU with following IEs: <ul style="list-style-type: none"> <li>• Message Type</li> <li>• RIC Request ID</li> <li>• RAN Function ID</li> <li>• RIC Control Header <ul style="list-style-type: none"> <li>○ UE ID</li> <li>○ RIC Style ID (Control)</li> <li>○ Control Action ID (1)</li> </ul> </li> <li>• RIC Control Message <ul style="list-style-type: none"> <li>○ List of RAN parameters (2)</li> <li>○ RAN Parameter ID (1)</li> <li>○ RAN Parameter Value <ul style="list-style-type: none"> <li>▪ MIMO Mode Index (2 = MU-MIMO)</li> </ul> </li> <li>○ RAN Parameter ID (2)</li> <li>○ RAN Parameter Value <ul style="list-style-type: none"> <li>▪ Non-GoB Beamforming Mode Index (A vendor-specific proprietary Non-GoB BF algorithm)</li> </ul> </li> </ul> </li> </ul> | +| 16 | O-DU sends RIC Control Acknowledge to Near RT-RIC | <b>O-DU → near RT-RIC</b> | Verify O-DU sends RIC CONTROL ACKNOWLEDGE to Near-RT RIC to inform Near RT-RIC that the message was received and to provide information on the outcome of the request. | + +| | | | | +|----|----------------------------|----------------------------------|-----------------------------------------------------------------------------------| +| | | | O-DU configures O-RU based on the optimized parameters received from Near RT-RIC. | +| 17 | Attach validation | UE $\leftrightarrow$ O-DU/O-CU | Verify that UE able to attach successfully. | +| 18 | End to end data validation | O-DU/ O-CU $\leftrightarrow$ UPF | Verify end to end data is successful. | + +## 7.78 ORAN.WG8.IOT.077: Verify successful cell bring-up of Shared O-RU in Single operator deployment. + +### 7.78.1 Test Purpose + +The purpose of this test case is to verify successful cell bring up when shared O-RU is configured with partitioned carrier#1 for O-DU#1 and partitioned carrier#2 for O-DU#2. + +### 7.78.2 Reference Requirement + +For detailed requirements, refer to the section 13.2 in ORAN-WG8.AAD [1]. + +### 7.78.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, Shared O-RU Operator SMO, O-DU#1, O-DU#2 and Shared O-RU is connected. +- It is assumed that sharing co-ordinator has successfully configured SMO to partition Shared O-RU between multiple O-DUs. +- It is assumed that SMO configures transport systems with call home identities for O-DUs. +- It is assumed that O-RU supports SHARED-ORU-MULTI-ODU feature. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- Shared O-RU is managed entirely by primary O-DU#1 using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU#1 is connected to O-DU#1 (Refer Section 4.20.3.1.2 of [38]). +- O-CU#2 is connected to O-DU#2 (Refer Section 4.20.3.1.2 of [38]). +- O-CU#1 and O-CU#2 is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DUs, the NETCONF Server is started or when the O-DUs are restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU#1 and O-DU#2 have obtained end to end IP connectivity with SMO. The O-DUs shall support either IPv4 or IPv6. + +- The PnfRegistration is successful with TLS secure connection is established between O-DUs and SMO as per test case ORAN.WG8.IOT.017 (Refer Section 6.7.2 of [28]). +- O-DUs and Shared O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.78.4 Test Setup and Configuration + +- **DUTs:** Shared O-RU Operator SMO, O-DU#1, O-DU#2, O-CU#1, O-CU#2 and Shared O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.9. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.78.5 Test Procedure + +The following table describes the test procedures to verify cell bring in Shared O-RU, Single MNO deployment. + +**Table 7.78-1: Cell bring-up in Shared O-RU, Single operator deployment** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|------------------------------------------------------------------------------------------------------------|---------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Power-on gNB including O-CUs, O-DUs and Shared O-RU. | <b>O-DUs ← O-RU</b> | Verify shared O-RU sends TCP connection request to each O-DU as part of call home procedure to establish NETCONF session. | +| 2 | Secured NETCONF session establishment between O-DUs and shared O-RU. | <b>O-RU / O-DUs</b> | Verify NETCONF hello capability messages are communicated between O-DUs and shared O-RU to establish successful NETCONF session at fronthaul interface. | +| 3 | SMO sends cell configuration and partitioned carrier information to O-DUs. | <b>O-DUs ← SMO</b> | Verify the cell configuration is received from SMO to O-DUs (O1 interface). | +| 4 | O-DUs sends partitioned carrier configuration to shared O-RU to establish C/U-Plane application endpoints. | <b>O-RU ← O-DUs</b> | Verify O-DUs sends the partitioned carrier configuration through file download request.<br><br>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE. | + +| | | | | +|----|--------------------------------------------------------------------------|------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 5 | O-RU sends sync-status information to O-DUs. | <b>O-RU → O-DUs</b> | <p>Verify shared O-RU is able to achieve time synchronization with GPS.</p> <p>Verify shared O-RU shall send the sync-status as LOCKED to O-DUs.</p> | +| 6 | Activate partitioned tx/rx array carriers. | <b>O-RU ← O-DUs</b> | <p>Verify O-DUs shall activate tx-array-carriers and rx-array-carriers in the U-Plane configuration by setting the value of the parameter "active" at tx-array-carrier element / rx-array-carrier element to "ACTIVE".</p> | +| 7 | O-DUs sends sync-state information and set the operational state in SMO. | <b>O-DUs → SMO</b> | <p>Verify O-DUs shall send the sync-state as LOCKED to SMO.</p> <p>Verify O-DUs set the operational state to ENABLED state.</p> | +| 8 | SMO shall set the administrative state of O-DUs. | <b>O-DUs ← SMO</b> | <p>Verify O-DUs shall set the administrative state to UNLOCKED state.</p> | +| 9 | Cell Bring-up | <b>O-DUs/O-CU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DUs monitors the synchronization-state-change notification periodically to ensure that shared O-RU is in LOCKED state and available for CUS-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DUs sets the administrative state to UNLOCKED state.</p> | +| 10 | Verify the status of the cell. | <b>O-DUs/O-CU</b> | <p>Verify SMO shows O-CUs and O-DUs operational and newly added cell is up and RF state of shared O-RU is ACTIVE.</p> <p>Verify shared O-RU sync-state is set to LOCKED state and available for CU-plane communication.</p> <p>Verify both cells are operational.</p> | +| 11 | UE#1 Attach validation with O-DU#1 | <b>UE#1 ← O-DU#1/ O-CU#1</b> | <p>Verify that UE able to attach successfully with partitioned O-DU#1.</p> | +| 12 | UE#2 Attach validation with O-DU#2 | <b>UE#2 ← O-DU#2/ O-CU#2</b> | <p>Verify that UE able to attach successfully with partitioned O-DU#2.</p> | +| 13 | Data is started in both DL and UL for UE#1. | <b>O-DU#1/ O-CU#1 → UPF</b> | <p>Verify that the values for "FrequencyDomainAllocation" "StartPRB" and "NoOfPRBs" in DL Scheduling Information (Refer Section 11.2.4.3.8 of [1]) align with the partitioning performed by the coordinator for O-DU#1.</p> <p>Verify end to end data is successful for UE#1</p> | +| 14 | Data is started in both DL and UL for UE#2. | <b>O-DU#2/ O-CU#2 → UPF</b> | <p>Verify that the values for "FrequencyDomainAllocation" "StartPRB" and "NoOfPRBs" in DL Scheduling Information (Refer Section 11.2.4.3.8 of [1]) align with the partitioning performed by the coordinator for O-DU#2.</p> <p>Verify end to end data is successful for UE#2</p> | + +## 7.79 ORAN.WG8.IOT.078: Verify successful detection for supervision failure of Shared O-RU in Single operator deployment. + +### 7.79.1 Test Purpose + +The purpose of this test case is to verify successful detection of supervision failure with an O-DU when watchdog timer expires. + +### 7.79.2 Reference Requirement + +For detailed requirements, refer to the section 13.2 in ORAN-WG8.AAD [1]. + +### 7.79.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, Shared O-RU Operator SMO, O-DU#1, O-DU#2 and Shared O-RU is connected. +- It is assumed that sharing co-ordinator has successfully configured SMO to partition Shared O-RU between multiple O-DUs. +- It is assumed that SMO configures transport systems with call home identities for O-DUs. +- It is assumed that O-RU supports SHARED-ORU-MULTI-ODU feature. +- odu-id is pre-provisioned in the o-ran-supervision YANG model for Shared O-RU to identify the O-DU#1 and O-DU#2. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- Shared O-RU is managed entirely by primary O-DU#1 using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU#1 is connected to O-DU#1 (Refer Section 4.20.3.1.2 of [38]). +- O-CU#2 is connected to O-DU#2 (Refer Section 4.20.3.1.2 of [38]). +- O-CU#1 and O-CU#2 is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DUs, the NETCONF Server is started or when the O-DUs are restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU#1 and O-DU#2 have obtained end to end IP connectivity with SMO. The O-DUs shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DUs and SMO as per test case ORAN.WG8.IOT.017 (Refer Section 6.7.2 of [28]) +- O-DUs are operating control and user plane for their respective partitioned carriers. + +- O-DUs and Shared O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.79.4 Test Setup and Configuration + +- **DUTs:** Shared O-RU Operator SMO, O-DU#1, O-DU#2, O-CU#1, O-CU#2 and Shared O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.9. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.79.5 Test Procedure + +The following table describes the test procedures to verify supervision failure of a shared O-RU. + +**Table 7.79-1: Supervision failure of Shared O-RU, Single operator deployment** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------------------------------------------------------------------------------------------------------|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends create-subscription message to shared O-RU via O-DUs. | <b>O-RU ← O-DUs</b> | Verify SMO sends the create-subscription message to shared O-RU via O-DU using NETCONF session. | +| 2 | SMO sends the create-subscription message to shared O-RU via O-DUs for the selected list of alarms supported. | <b>O-RU ← O-DUs</b> | Verify SMO sends the create-subscription message for the selected list of alarms to shared O-RU via O-DUs as per Annex A of [24]. | +| 3 | Shared O-RU sends supervision-notification to O-DUs at the expiry of notification timer | <b>O-RU → O-DUs</b> | Verify O-DUs confirms that NETCONF connectivity to the shared O-RU is operational by receiving the notification.<br><br>Verify O-DUs send supervision-watchdog-reset notification including odu-id before supervision timer expiry. | +| 4 | Power Off the switch hosting the netconf session for O-DU#2. | <b>O-RU/O-DU#2</b> | Verify supervision-watchdog-reset notification from O-DU#2 was not received by the Shared O-RU before supervision timer expiry. | +| 5 | Due to supervision failure tx-array-carriers and rx-array-carriers are disabled. | <b>O-RU</b> | Verify the shared O-RU should disable the tx-array-carriers and rx-array-carriers in the U-Plane configuration by setting the value of the parameter | + +| | | | | +|---|------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | "inactive" at tx-array-carrier element / rx-array-carrier element to "INACTIVE" for O-DU#2. | +| 6 | De-activate the cell from the O-DU#2. | <b>O-DU#2 → O-CU#2</b> | <p>O-DU#2 sends the F1AP gNB-DU configuration update to O-CU#2.</p> <p>F1AP gNB-DU configuration update message should contain all the mandatory IEs mentioned in section 4.1.6.1.2.5 of ORAN.WG5.C.1 [19].</p> <p>O-DU#2 should de-activate the cell information according to the service-state IE.</p> | +| 7 | Shared O-RU reports the alarm (Lost O-DU ID based supervision) for the SUBSCRIBED alarm to O-DU1. O-DU#1 forwards the reported alarms notification to SMO. | <b>O-DU#1 → SMO</b> | <p>Verify shared O-RU reports the below alarm notification for the SUBSCRIBED alarm to O-DU#1 and O-DU#1 forwards the SUBSCRIBED alarm to SMO.</p> <p>#35 "Lost O-DU ID based Supervision "</p> | +| 8 | Periodical call home towards O-DU#2. | <b>O-RU → O-DU#2</b> | Verify O-RU remains operational and performs periodical Call Home towards O-DU#2. | +| 9 | Cell Bring-up is successful for recovered supervision session when switch is powered on. | <b>O-DU#2/O-CU#2</b> | <p>Verify Alarm ID #35 is cleared on the SMO.</p> <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU#2 monitors the synchronization-state-change notification periodically to ensure that shared O-RU is in LOCKED state and available for CUS-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU#2 sets the administrative state to UNLOCKED state.</p> | + +## 7.80 ORAN.WG8.IOT.079: Verify successful performance management of a Shared O-RU in Single operator deployment. + +### 7.80.1 Test Purpose + +The purpose of this test case is to verify that each O-DU has established subscriptions to receive performance management notifications from shared O-RU. + +### 7.80.2 Reference Requirement + +For detailed requirements, refer to the section 13.2 in ORAN-WG8.AAD [1]. + +### 7.80.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, Shared O-RU Operator SMO, O-DU#1, O-DU#2 and Shared O-RU is connected. +- It is assumed that sharing co-ordinator has successfully configured SMO to partition Shared O-RU between multiple O-DUs. +- It is assumed that SMO configures transport systems with call home identities for O-DUs. + +- It is assumed that O-RU supports SHARED-ORU-MULTI-ODU feature. +- It is assumed that O-DUs are identified by the sro-id (shared resource operator-id) with access privileges as defined in section 19.3.3 [24]. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- Shared O-RU is managed entirely by primary O-DU#1 using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU#1 is connected to O-DU#1 (Refer Section 4.20.3.1.2 of [38]). +- O-CU#2 is connected to O-DU#2 (Refer Section 4.20.3.1.2 of [38]). +- O-CU#1 and O-CU#2 is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DUs, the NETCONF Server is started or when the O-DUs are restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU#1 and O-DU#2 have obtained end to end IP connectivity with SMO. The O-DUs shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DUs and SMO as per test case ORAN.WG8.IOT.017 (Refer Section 6.7.2 of [28]). +- O-DUs are operating control and user plane for their respective partitioned carriers. +- O-DUs and Shared O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.80.4 Test Setup and Configuration + +- **DUTs:** Shared O-RU Operator SMO, O-DU#1, O-DU#2, O-CU#1, O-CU#2 and Shared O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.9. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.80.5 Test Procedure + +The following table describes the test procedures to verify performance management of a shared O-RU. + +**Table 7.80-1: Performance management of Shared O-RU, Single operator deployment** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|----------------------------------------------------------------------------|------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell Bring-up | <b>O-DUs/O-CU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DUs monitors the synchronization-state-change notification periodically to ensure that shared O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DUs sets the administrative state to UNLOCKED state.</p> <p>Verify both cells are operational.</p> | +| 2 | UE#1 Attach validation with O-DU#1 | <b>UE#1 ← O-DU#1/ O-CU#1</b> | Verify that UE able to attach successfully with partitioned O-DU#1. | +| 3 | UE#2 Attach validation with O-DU#2 | <b>UE#2 ← O-DU#2/ O-CU#2</b> | Verify that UE able to attach successfully with partitioned O-DU#2. | +| 4 | Data is started in both DL and UL for UE#1. | <b>O-DU#1/ O-CU#1 → UPF</b> | <p>Verify that the values for "FrequencyDomainAllocation" "StartPRB" and "NoOfPRBs" in DL Scheduling Information (Refer Section 11.2.4.3.8 of [1]) align with the partitioning performed by the coordinator for O-DU#1.</p> <p>Verify end to end data is successful for UE#1</p> | +| 5 | Data is started in both DL and UL for UE#2. | <b>O-DU#2/ O-CU#2 → UPF</b> | <p>Verify that the values for "FrequencyDomainAllocation" "StartPRB" and "NoOfPRBs" in DL Scheduling Information (Refer Section 11.2.4.3.8 of [1]) align with the partitioning performed by the coordinator for O-DU#2.</p> <p>Verify end to end data is successful for UE#2</p> | +| 6 | O-DU#1 collects the performance counters and reports it to O-DU-OAM-Agent. | <b>O-DU#1 → SMO</b> | <p>Verify the following APIs are sent from MAC towards O-DU-OAM-Agent containing the performance counters as mentioned in ORAN-WG8.AAD [1]:</p> <ul style="list-style-type: none"> <li>• RSRP/RSRQ/SINR measurements</li> <li>• Measurement for the SSB beam switch</li> <li>• Beam Failure statistics per cell per beam</li> <li>• UL SRS RSRP measurement</li> </ul> | +| 7 | PM Data File ready notification by O-DU-OAM-Agent. | <b>O-DU#1 → SMO</b> | Verify O-DU-OAM-Agent sends notifyFileReady notification towards SMO as mentioned in [22] with the correct PM File Content and naming as mentioned in [28]. | + +| | | | | +|---|----------------------------------------------------------------------------|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | SMO successfully received the Performance Measurements file.<br><br>SMO can use it for parameter optimization and reconfiguration of parameters on O1 interface. | +| 8 | O-DU#2 collects the performance counters and reports it to O-DU-OAM-Agent. | <b>O-DU#2 → SMO</b> | Verify the following APIs are sent from MAC towards O-DU-OAM-Agent containing the performance counters as mentioned in ORAN-WG8.AAD [1]: <ul style="list-style-type: none"> <li>• RSRP/RSRQ/SINR measurements</li> <li>• Measurement for the SSB beam switch</li> <li>• Beam Failure statistics per cell per beam</li> <li>• UL SRS RSRP measurement</li> </ul> | +| 9 | PM Data File ready notification by O-DU-OAM-Agent. | <b>O-DU#2 → SMO</b> | Verify O-DU-OAM-Agent sends notifyFileReady notification towards SMO as mentioned in [22] with the correct PM File Content and naming as mentioned in [28].<br><br>SMO successfully received the Performance Measurements file.<br><br>SMO can use it for parameter optimization and reconfiguration of parameters on O1 interface. | + +## 7.81 ORAN.WG8.IOT.080: Verify successful switchover from active to standby O-DU node in Single operator deployment. + +### 7.81.1 Test Purpose + +The purpose of this test case is to verify basic resiliency operation with the shared O-RU. + +### 7.81.2 Reference Requirement + +For detailed requirements, refer to the section 13.2 in ORAN-WG8.AAD [1]. + +### 7.81.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, Shared O-RU Operator SMO, O-DU#1, O-DU#2 and Shared O-RU is connected. +- It is assumed that sharing co-ordinator has successfully configured SMO to partition Shared O-RU between multiple O-DUs. +- It is assumed that SMO configures transport systems with call home identities for O-DUs. +- It is assumed that O-RU supports SHARED-ORU-MULTI-ODU feature. +- It is assumed that O-DU#2 has been pre-provisioned with the same carrier configuration as O-DU#1. +- It is assumed that the call home operation is successful with O-DU#2 and it is currently in stand-by mode. +- odu-id is pre-provisioned in the o-ran-supervision YANG model for Shared O-RU to identify the O-DU#1 and O-DU#2. + +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- Shared O-RU is managed entirely by primary O-DU#1 using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU#1 is connected to O-DU#1 and standby O-DU#2. (Refer Section 4.20.3.1.2 of [38]). +- O-CU#1 is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DUs, the NETCONF Server is started or when the O-DUs are restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU#1 and O-DU#2 have obtained end to end IP connectivity with SMO. The O-DUs shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DUs and SMO as per test case ORAN.WG8.IOT.017 (Refer Section 6.7.2 of [28]). +- O-DU#1 is operating CUS plane for its respective partitioned carrier. +- O-DUs have subscribed to alarm notifications successfully. +- There are many possible operations to trigger the resiliency use case, only full failure of a O-DU is considered in this use case. +- O-DUs and Shared O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.81.4 Test Setup and Configuration + +- **DUTs:** Shared O-RU Operator SMO, O-DU#1, O-DU#2, O-CU#1 and Shared O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.9. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.81.5 Test Procedure + +The following table describes the test procedures to verify basic resiliency operation with a shared O-RU. + +**Table 7.81-1: Basic resiliency with shared O-RU, Single operator deployment** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-----------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell Bring-up | <b>O-DU#1/O-CU#1</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU#1 monitors the synchronization-state-change notification periodically to ensure that shared O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DUs sets the administrative state to UNLOCKED state.</p> | +| 2 | O-DU#1 fails. (Due to scenarios like power outage or GPS sync loss) | <b>O-DU#1</b> | Verify O-DU#1 set the operational state as DISABLED. | +| 3 | Shared O-RU losses communication with O-DU#1. | <b>O-DU#1 → O-RU</b> | Verify supervision-watchdog-reset notification from O-DU#1 was not received by the Shared O-RU before supervision timer expiry. | +| 4 | Due to supervision failure tx-array-carriers and rx-array-carriers are disabled. | <b>O-RU</b> | Verify the shared O-RU should disable the tx-array-carriers and rx-array-carriers in the U-Plane configuration by setting the value of the parameter "inactive" at tx-array-carrier element / rx-array-carrier element to "INACTIVE" for O-DU#1. | +| 5 | Shared O-RU reports the alarm (Lost O-DU ID based supervision) for the SUBSCRIBED alarm to O-DU#2. O-DU forwards the reported alarms notification to SMO. | <b>O-DU#2 → SMO</b> | <p>Verify shared O-RU reports the below alarm notification for the SUBSCRIBED alarm to O-DU#2 and O-DU#2 forwards the SUBSCRIBED alarm to SMO.</p> <p>#35 "Lost O-DU ID based Supervision "</p> | +| 6 | SMO activates the standby O-DU#2 as active Primary O-DU by setting the administrative state of O-DU#2. | <b>O-DU#2 ← SMO</b> | <p>Verify O-DU#2 shall set the operational state as ENABLED.</p> <p>Verify O-DU#2 shall set the administrative state to UNLOCKED state.</p> | +| 7 | Activate partitioned tx/rx array carriers using the replica configuration of shared O-RU at O-DU#2. | <b>O-RU ← O-DU#2</b> | Verify O-DU#2 shall activate tx-array-carriers and rx-array-carriers in the U-Plane configuration by setting the value of the parameter "active" at tx-array-carrier element / rx-array-carrier element to "ACTIVE" for O-DU#2. | +| 8 | Cell Bring-up is successful. | <b>O-DU#2/O-CU#1</b> | <p>Verify cell bring-up is successful.</p> <p>O-DU#2 monitors the synchronization-state-change notification periodically to ensure that shared O-RU is in LOCKED state and available for CUS-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU#2 sets the administrative state to UNLOCKED state.</p> | +| 9 | UE Attach validation with O-DU#2 | <b>UE ← O-DU#2/ O-CU#1</b> | Verify that UE able to attach successfully with O-DU#2. | + +| | | | | +|----|-----------------------------------------------|-----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 10 | Data is started in both DL and UL for the UE. | <b>O-DU#2/ O-CU#1 → UPF</b> | <p>Verify that the values for "FrequencyDomainAllocation" "StartPRB" and "NoOfPRBs" in DL Scheduling Information (Refer Section 11.2.4.3.8 of [1]) align with the partitioning performed by the coordinator for O-DU#2.</p> <p>Verify end to end data is successful for the UE.</p> | +|----|-----------------------------------------------|-----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +## 7.82 ORAN.WG8.IOT.081: Verify successful scale-out operation for a O-DU node by the SMO in Single operator deployment. + +### 7.82.1 Test Purpose + +The purpose of this test case is to verify scale-out operation for an O-DU by the SMO in single operator shared O-RU deployment. + +### 7.82.2 Reference Requirement + +For detailed requirements, refer to the section 13.2 in ORAN-WG8.AAD [1]. + +### 7.82.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, Shared O-RU Operator SMO, O-DU#1, O-DU#2 and Shared O-RU is connected. +- It is assumed that sharing co-ordinator has successfully configured SMO to partition Shared O-RU between multiple O-DUs. +- It is assumed that SMO configures transport systems with call home identities for O-DUs. +- It is assumed that O-RU supports SHARED-ORU-MULTI-ODU feature. +- odu-id is pre-provisioned in the o-ran-supervision YANG model for Shared O-RU to identify the O-DU#1 and O-DU#2. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- Shared O-RU is managed entirely by primary O-DU#1 using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU#1 is connected to O-DU#1 (Refer Section 4.20.3.1.2 of [38]). +- O-CU#2 is connected to O-DU#2 (Refer Section 4.20.3.1.2 of [38]). +- O-CU#1 and O-CU#2 is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DUs, the NETCONF Server is started or when the O-DUs are restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU#1 and O-DU#2 have obtained end to end IP connectivity with SMO. The O-DUs shall support either IPv4 or IPv6. + +- The PnfRegistration is successful with TLS secure connection is established between O-DUs and SMO as per test case ORAN.WG8.IOT.017 (Refer Section 6.7.2 of [28]). +- O-DU#1 is operating CUS plane for its respective partitioned carrier. +- O-DU#1 have subscribed to alarm notifications successfully. +- O-DUs and Shared O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.82.4 Test Setup and Configuration + +- **DUTs:** Shared O-RU Operator SMO, O-DU#1, O-DU#2, O-CU#1, O-CU#2 and Shared O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.9. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.82.5 Test Procedure + +The following table describes the test procedures to verify scale-out operation for an O-DU. + +**Table 7.82-1: Scale-out operation for O-DU with shared O-RU, Single operator deployment** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------|----------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell Bring-up | <b>O-DU#1/O-CU#1</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU#1 monitors the synchronization-state-change notification periodically to ensure that shared O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DUs sets the administrative state to UNLOCKED state.</p> | + +| | | | | +|----|-------------------------------------------------------------------------------------------------------------|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2 | SMO triggers capacity modification processing. | <b>SMO</b> | <p>SMO determines that scale out is needed and determines what deployment scaling is required to increase shared O-RU capacity.</p> <p>This is vendor specific, and the scale-out algorithm can vary depending on the implementation/design.</p> <p>Few examples for scale-out:</p> <ul style="list-style-type: none"> <li>• UE based scaling.</li> <li>• Network Energy Saving.</li> </ul> <p>Note: As per section 3.2.2 of [32], scaling is managed by the SMO. Self-management of scaling by the NF is for future study.</p> | +| 3 | Call home towards O-DU#2. | <b>O-DU#2 ← O-RU</b> | Verify shared O-RU sends TCP connection request to O-DU#2 as part of call home procedure to establish NETCONF session. | +| 4 | Secured NETCONF session establishment between O-DU#2 and shared O-RU. | <b>O-RU / O-DU#2</b> | Verify NETCONF hello capability messages are communicated between O-DU#2 and shared O-RU to establish successful NETCONF session at fronthaul interface. | +| 5 | SMO sends cell configuration and partitioned carrier information to O-DU#2. | <b>O-DU#2 ← SMO</b> | Verify the cell configuration is received from SMO to O-DU#2 (O1 interface). | +| 6 | O-DU#2 sends partitioned carrier configuration to shared O-RU to establish C/U-Plane application endpoints. | <b>O-RU ← O-DU#2</b> | <p>Verify O-DU#2 sends the partitioned carrier configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE.</p> | +| 7 | O-RU sends sync-status information to O-DU#2. | <b>O-RU → O-DU#2</b> | <p>Verify shared O-RU is able to achieve time synchronization with GPS.</p> <p>Verify shared O-RU shall send the sync-status as LOCKED to O-DUs.</p> | +| 8 | Activate partitioned tx/rx array carriers. | <b>O-RU ← O-DU#2</b> | Verify O-DU#2 shall activate tx-array-carriers and rx-array-carriers in the U-Plane configuration by setting the value of the parameter "active" at tx-array-carrier element / rx-array-carrier element to "ACTIVE". | +| 9 | O-DU#2 sends sync-state information and set the operational state in SMO. | <b>O-DU#2 → SMO</b> | <p>Verify O-DU#2 shall send the sync-state as LOCKED to SMO.</p> <p>Verify O-DU#2 set the operational state to ENABLED state.</p> | +| 10 | SMO shall set the administrative state of O-DU#2. | <b>O-DU#2 ← SMO</b> | Verify O-DU#2 shall set the administrative state to UNLOCKED state. | +| 11 | Cell Bring-up | <b>O-DU#2/O-CU#2</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU#2 monitors the synchronization-state-change notification periodically to ensure that shared O-RU is in LOCKED state and available for CUS-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU#2 sets the administrative state to UNLOCKED state.</p> | + +| | | | | +|----|---------------------------------------------|------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 12 | Verify the status of the cell. | <b>O-DU#2/O-CU#2</b> | Verify SMO shows O-CU#2 and O-DU#2 operational and newly added cell is up and RF state of shared O-RU is ACTIVE.<br><br>Verify shared O-RU sync-state is set to LOCKED state and available for CU-plane communication. | +| 13 | UE#1 Attach validation with O-DU#2 | <b>UE#1 ← O-DU#2/ O-CU#2</b> | Verify that UE able to attach successfully with partitioned O-DU#2. | +| 14 | Data is started in both DL and UL for UE#1. | <b>O-DU#2/ O-CU#2 → UPF</b> | Verify that the values for "FrequencyDomainAllocation" "StartPRB" and "NoOfPRBs" in DL Scheduling Information (Refer Section 11.2.4.3.8 of [1]) align with the partitioning performed by the coordinator for O-DU#2.<br><br>Verify end to end data is successful for UE#1. | + +## 7.83 ORAN.WG8.IOT.082: Verify successful software upgrade for O-RU triggered by O-DU. + +### 7.83.1 Test Purpose + +The purpose of this test case is to verify successful software upgrade for an O-RU when a new software image is available and upgrade is initiated by O-DU. + +### 7.83.2 Reference Requirement + +For detailed requirements, refer to the section 13.2 in ORAN-WG8.AAD [1] and Chapter 8 in ORAN-WG4.MP.0-R003-v14.00. + +### 7.83.3 Initial Conditions + +Following are the preconditions for this test. + +- O-RU is connected to O-DU. +- O-RU is implemented as a physical Network Function and deployed remotely. O-RU is connected to O-DU using O-RAN WG4 defined hierarchical approach (Refer Chapter 2.3 of [22]), Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-DU provides the software inventory information of connected O-RU to the SMO. +- SMO establishes NETCONF session with O-DU. +- Appropriate software file for O-RU is pre-installed in O-RU and corresponding manifest.xml is located in O-DU. +- O-DU has subscribed to receive **download/install/activation -event** notifications. +- At least one software slot with status **active::False** and **running::False** exists in O-RU. + +## 7.83.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup see A.8. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.83.5 Test Procedure + +The following table describes the test procedures to verify successful software upgrade for an O-RU when a new software image is available and upgrade is initiated by O-DU. + +**Table 7.83-1: Software upgrade of O-RU** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|------------------------------------------------|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO triggers the software download to O-RU | <b>O-RU ← O-DU</b> | SMO sends NETCONF to trigger download of the software to O-DU.<br><br>Verify O-DU sends file-download request to O-RU with remote file path to download software file from a file server and should ensure that all the files necessary for the O-RU are transferred from the file server to the O-RU. | +| 2 | O-RU downloads software files | <b>O-RU → O-DU</b> | Verify O-RU sends response towards O-DU with status of the file-download request as accepted. Software-download RPC triggers the O-RU to download a file<br><br>Verify O-RU sends a notification for the result of the download process as successfully downloaded once the download is successful. | +| 3 | O-DU triggers the installation of the software | <b>O-RU/O-DU</b> | Verify O-DU requests installation of the software using software-install RPC, and provides the slot name where the software needs to be installed along with a list of filenames to be installed<br><br>Verify O-RU sends a notification about completion of the sw installed. | +| 4 | O-DU triggers the activation of the software | <b>O-RU/O-DU</b> | Verify O-DU requests the O-RU to activate the slot that contains the newly installed software using the software-activate rpc.<br><br>Verify O-RU sends a notification about completion of the sw activation procedure. | + +| | | | | +|---|--------------------------------|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | Verify O-DU restarts the O-RU and O-RU comes up with newly installed and activated software. | +| 5 | Cell Bring-up | <b>O-DU/O-CU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify new instance of O-DU sets the administrative state to UNLOCKED state.</p> | +| 6 | Verify the status of the cell. | <b>O-DU/O-CU</b> | <p>Verify SMO shows O-CU and new instance of O-DU operational and newly added cell is up and RF state of O-RU is ACTIVE.</p> <p>Verify O-RU sync-state is set to LOCKED state and available for CU-plane communication.</p> | +| 7 | Attach validation | <b>UE ← O-DU/ O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration. | +| 8 | End to end data validation | <b>O-DU#2/ O-CU#2 → UPF</b> | Verify end to end data is successful. | + +## 7.84 ORAN.WG8.IOT.083: Verify successful configuration and data header compression/de-compression at O-CU when RoHC profile “0x0001” is used for “RTP/UDP/IP”. + +### 7.84.1 Test Purpose + +The purpose of this test case is to verify successful configuration and data header compression/de-compression at O-CU when RoHC profile “0x0001” is used for “RTP/UDP/IP”. + +### 7.84.2 Reference Requirements + +For detailed requirements, refer to the section 12.6 in ORAN-WG8.AAD [1]. + +### 7.84.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- F1AP connection is successful between O-CU and O-DU. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). + +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- SMO pre-configures RoHC profile “0x0001” for 5QI-1 to be used at O-CU. + +## 7.84.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- IMS to provide support for VoNR. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP, SIP protocol content. +- Configuration: + - For details on the test setup refer Annex A.1. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + - For details on the IMS test profiles, see B.10. + +## 7.84.5 Test Procedure + +The following table below describes the test steps to verify RoHC configuration and header compression/de-compression. + +**Table 7.84-1: Registration & data transfer when RoHC is enabled** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------------------------|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | The UE sends RRCSetupRequest with random ue-identity and establishment cause (refer to the section 5.3.3 in 3GPP 38.331 [8]). | <b>UE → O-DU/<br/>O-CU</b> | Verify that O-DU receives the RRC setup Request message from the UE and sends Initial UL RRC message to O-CU with RRC setup request message in RRC container.<br><br>Verify all the mandatory IEs of Initial UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19]. | + +| | | | | +|---|----------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2 | UE receives RRCsetup message for SRB1 creation. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU sends DL RRC message transfer to O-DU with RRC setup message in the RRC container to establish SRB1.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends RRC setup message to UE.</p> <p>Verify all the mandatory IEs of RRC setup as per section 6.2.2 in 3GPP Specification. [8].</p> | +| 3 | UE sends RRC setup complete message over SRB1 with Registration Request as NAS payload. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC setup complete message with registration request as NAS payload from UE and sends UL RRC message transfer to O-CU with RRC setup complete and Registration Request message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Initial UE Message to AMF with NAS payload as Registration Request.</p> <p>Verify all the mandatory IEs of Initial UE message as per section 9.2.5.1 of 3GPP Specification [20].</p> | +| 4 | UE receives NAS Authentication Request message from AMF with authentication parameters required for successfully authenticating the network. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives DL NAS Transport message with Authentication request as NAS payload.</p> <p>Verify that O-CU sends DL RRC Message Transfer to O-DU with NAS Authentication Request in the RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Authentication request message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> | +| 5 | UE sends NAS Authentication response message after successfully authenticating the network. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Authentication Response message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Authentication response in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Authentication Response as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 6 | UE receives NAS Security mode command message for integrity protection and ciphering. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives DL NAS Transport message with security mode command as NAS payload.</p> <p>Verify that O-CU sends DL RRC Message Transfer to O-DU with NAS Security mode command in the RRC container</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Security mode command message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> | + +| | | | | +|----|------------------------------------------------------------------------------------------------|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 7 | UE sends NAS Security mode complete message. This message is integrity protected and ciphered. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Security mode complete message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Security mode complete message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Security mode complete as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 8 | UE receives AS security mode command message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives Initial context setup request or DL NAS Transport from AMF with Registration accept as NAS payload.</p> <p>Verify all the mandatory IEs as per the section 9.2.2.1 or 9.2.5.2 in 3GPP Specification [20].</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU with AS security mode command message in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify the O-DU sends SecurityModeCommand to UE which contains AS integrity and Ciphering Algorithms supported by O-CU.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> | +| 9 | UE sends AS Security mode complete message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify in response of previous step, the O-DU receives SecurityModeComplete from UE.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains AS security mode complete in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | +| 10 | UE receives UE capability Enquiry message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives the UE radio capability check request from AMF to check the compatibility between UE radio capabilities and network configuration.</p> <p>O-CU can optionally request for the UE capability enquiry to the UE.</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU which contains UE capability enquiry in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends UE capability enquiry to UE to check the UE capabilities.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> | +| 11 | UE sends UE capability information message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UE capability information from UE.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> | + +| | | | | +|----|----------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains UE capability information in the RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UE Radio Capability Info Indication message to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.13.1 in 3GPP Specification [20].</p> <p>Verify PDCP-Parameters within UE-NR-Capability have “supportedROHC-Profiles” with “profile0x0001” is set to true as per 3GPP Specification [8].</p> <p>Verify that “voiceOverNR” within IMS Parameters is set to supported as per 3GPP Specification [8].</p> | +| 12 | UE receives Registration Accept message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU sends DL RRC message transfer to O-DU which contains Registration Accept in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Registration accept message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> <p>Verify 5GS “IMS voice over PS session supported over 3GPP access” bit is set to 1 within Network Feature Support.</p> | +| 13 | UE sends Registration complete message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Registration complete message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Registration complete message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Initial context setup response to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.2.2 in 3GPP Specification [20].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Registration complete as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 14 | The UE sends PDU session Establishment Request with PDU session id (refer to the section 8.3.1 in 3GPP Specification [21]) for Internet session establishment. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify PDU session establishment is successful for 5QI 9.</p> | +| 15 | The UE sends PDU session Establishment Request with PDU session id (refer to the section 8.3.1 in 3GPP Specification [21]) for IMS session establishment. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UL information transfer message which contains PDU session establishment request as NAS message.</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains PDU session establishment request in RRC container.</p> | + +| | | | | +|----|-------------------------------------------------------------------------------|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Uplink NAS transport with NAS PDU as PDU Session Establishment Request to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 16 | UE receives RRC reconfiguration and PDU session establishment accept message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives PDU Session Resource Setup Request from AMF with NAS-PDU as PDU session establishment accept.</p> <p>Verify all the mandatory IEs as per section 9.2.1.1 in 3GPP Specification [20].</p> <p>Verify that O-CU sends UE context setup request to O-DU for establishing the DRB.</p> <p>Verify all the mandatory IEs of UE context setup request as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends UE context setup response to O-CU after successfully establishing the DRB.</p> <p>Verify all the mandatory IEs of UE context setup response as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU with RRC reconfiguration in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends RRC reconfiguration message to UE which contains PDU session establishment accept as NAS payload.</p> | +| 17 | UE sends RRC reconfiguration complete. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives RRC reconfiguration complete from UE.</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU with RRC reconfiguration complete in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends PDU Session Resource Setup Response to AMF over NG interface.</p> <p>Verify all the mandatory IEs as per section 9.2.1.2 in 3GPP Specification [20].</p> | +| 18 | IMS: SIP Registration | <b>UE → IMS</b> | <p>Verify SIP Setup before Voice Traffic is successful.</p> | +| 19 | Trigger voice call from UE#1 to UE#2. | <b>O-CU/O-DU<br/>← AMF</b> | <p>Verify that O-CU receives NGAP PDU Session Resource Modify Request message which contains the Information about the PDU Session and the flow for establishment of 5QI=1.</p> <p>NGAP PDU Session Resource Modify Request contains all the Mandatory IEs mentioned in the section 9.2.1.5 and 9.3.4.3 of 3GPP Specification [20].</p> <p>Verify that O-CU sends F1AP UE Context Modification Request message to O-DU.</p> <p>F1AP UE Context Modification Request message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> | + +| | | | | +|----|--------------------------------------------------------------------------------------|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify that O-DU sends F1AP UE Context Modification Response message to O-CU.</p> <p>F1AP UE Context Modification Response message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends F1AP DL RRC Message Transfer Request with RRC reconfiguration message in RRC container to O-DU and the message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 20 | UE receives RRC reconfiguration and 5G SM: PDU session Modification Command message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-DU sends RRC reconfiguration message to UE and the RRC Reconfiguration message contains all the mandatory IEs mentioned in the 3GPP Specification [8].</p> <p>Verify that UE receives RRCReconfiguration with drb-ToAddModList, pdu-Session, mappedQoS-FlowToAdd, pdcp-config with headerCompression enabled to setup 5QI 1 in RLC UM mode as per 3GPP Specification [8].</p> <ul style="list-style-type: none"> <li>• PDCP-Config <ul style="list-style-type: none"> <li>◦ drb</li> <li>◦ headerCompression <ul style="list-style-type: none"> <li>▪ rohc <ul style="list-style-type: none"> <li>• maxCID 15</li> <li>• profiles</li> <li>• profile0x0001 true</li> <li>• profile0x0002 false</li> <li>• profile0x0003 false</li> <li>• profile0x0004 false</li> <li>• profile0x0006 false</li> <li>• profile0x0101 false</li> <li>• profile0x0102 false</li> <li>• profile0x0103 false</li> <li>• profile0x0104 false</li> </ul> </li> </ul> </li> </ul> </li> </ul> | +| 21 | UE sends RRC Reconfiguration Complete. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC Reconfiguration Complete message and sends F1AP UL RRC message transfer to O-CU which contains RRC Reconfiguration Complete inside RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | +| 22 | O-CU sends NGAP PDU Session Resource Modify Response message to AMF. | <b>O-DU/O-CU<br/>→ AMF</b> | <p>Verify that AMF receives the NGAP PDU Session Resource Modify Response.</p> <p>NGAP PDU Session Resource Modify Response contains all the Mandatory IEs mentioned in the section 9.2.1.6 and 9.3.4.3 of 3GPP Specification [20].</p> <p>Verify that O-CU sends F1AP UE Context Modification Request to O-DU.</p> <p>F1AP UE Context Modification Request message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends F1AP UE Context Modification Response message to O-CU.</p> <p>F1AP UE Context Modification Response message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> | + +| | | | | +|----|--------------------------------------------------------------------------------------------------------------|-------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 23 | UE sends UL Information Transfer message containing the NAS message 5GSM: PDU Session Modification Complete. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the sends UL Information Transfer message and sends UL RRC message transfer to O-CU.</p> <p>Verify that O-CU sends NGAP Uplink NAS Transport Message to AMF with NAS payload as 5GSM: PDU Session Modification Complete.</p> | +| 24 | Start RTP voice traffic. | <b>UE#1 ↔ O-DU/O-CU<br/>↔ CN/IMS<br/>↔ UE#2</b> | <p>Verify that end-to-end speech packet transfer is successful by ensuring that downlink data header is compressed at the gNB and decompressed at the UE, and that uplink data header is compressed at the UE and decompressed at the gNB.</p> <p>Verify successful header compression and de-compression from gNB Wireshark and UE logs.</p> <p>Verify that the end-to-end voice call is successful.</p> <p>Verify that enabling RoHC does not cause any performance impact.</p> <p>Note: There might be slight impact on CPU utilization due to additional processing of compression/de-compression of header when RoHC is enabled.</p> | +| 25 | Terminate the voice call from UE#1. | <b>O-CU/O-DU<br/>← AMF</b> | <p>Verify that O-CU receives NGAP PDU Session Resource Modify Request message which contains the Information about the PDU Session and the flow for deletion of 5QI=1.</p> <p>NGAP PDU Session Resource Modify Request contains all the Mandatory IEs mentioned in the section 9.2.1.5 and 9.3.4.3 of 3GPP Specification [20].</p> <p>Verify that O-CU sends F1AP UE Context Modification Request message to O-DU.</p> <p>F1AP UE Context Modification Request message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends F1AP UE Context Modification Response message to O-CU.</p> <p>F1AP UE Context Modification Response message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends F1AP DL RRC Message Transfer Request with RRC reconfiguration message in RRC container to O-DU and the message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 26 | UE receives RRC reconfiguration and 5G SM: PDU session Modification Command message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-DU sends RRC reconfiguration message to UE and the RRC Reconfiguration message contains all the mandatory IEs mentioned in the 3GPP Specification [8].</p> <p>Verify that UE receives RRCReconfiguration with drb-ToReleaseList to release 5QI 1 as per 3GPP Specification [8].</p> | +| 27 | UE sends RRC Reconfiguration Complete. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC Reconfiguration Complete message and sends F1AP UL RRC message transfer to O-CU which contains RRC Reconfiguration Complete inside RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | + +| | | | | +|----|--------------------------------------------------------------------------------------------------------------|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 28 | O-CU sends NGAP PDU Session Resource Modify Response message to AMF. | <b>O-DU/O-CU<br/>→ AMF</b> | <p>Verify that AMF receives the NGAP PDU Session Resource Modify Response.</p> <p>NGAP PDU Session Resource Modify Response contains all the Mandatory IEs mentioned in the section 9.2.1.6 and 9.3.4.3 of 3GPP Specification [20].</p> <p>Verify that O-CU sends F1AP UE Context Modification Request to O-DU.</p> <p>F1AP UE Context Modification Request message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends F1AP UE Context Modification Response message to O-CU.</p> <p>F1AP UE Context Modification Response message contains all the mandatory IEs mentioned in section 6.3.1.2.1 of ORAN.WG5.C.1 [19].</p> | +| 29 | UE sends UL Information Transfer message containing the NAS message 5GSM: PDU Session Modification Complete. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the sends UL Information Transfer message and sends UL RRC message transfer to O-CU.</p> <p>Verify that O-CU sends NGAP Uplink NAS Transport Message to AMF with NAS payload as 5GSM: PDU Session Modification Complete.</p> | + +## 7.85 ORAN.WG8.IOT.084: Verify successful configuration and data header compression/de-compression at O-CU when RoHC profile “0x0002” is used for “UDP/IP”. + +### 7.85.1 Test Purpose + +The purpose of this test case is to verify successful configuration and data header compression/de-compression at O-CU when RoHC profile “0x0002” is used for “UDP/IP”. + +### 7.85.2 Reference Requirements + +For detailed requirements, refer to the section 12.6 in ORAN-WG8.AAD [1]. + +### 7.85.3 Initial Conditions + +Following are the preconditions for this test. + +- Cell bring-up is successful with default configuration. +- F1AP connection is successful between O-CU and O-DU. +- O-DU and O-RU are time synchronized. O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of ORAN.WG4.MP [24]). +- The UE has decoded MIB and SIB1. +- RACH procedure is successful. +- SMO pre-configures RoHC profile “0x0002” for 5QI-9 to be used at O-CU. + +## 7.85.4 Test Setup and Configuration + +- **DUTs:** single O-DU and single O-CU +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or Core emulator used to terminate UEs (emulator) NAS protocol, and to support NGAP, HTTP2, PFCP protocols. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP, SIP protocol content. +- Configuration: + - For details on the test setup refer Annex A.1. + - For details on the MIB and SSB test profiles, see B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.85.5 Test Procedure + +The following table below describes the test steps to verify RoHC configuration and header compression/de-compression. + +**Table 7.85-1: Registration & data transfer when RoHC is enabled** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|-------------------------------------------------------------------------------------------------------------------------------|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | The UE sends RRCSetupRequest with random ue-identity and establishment cause (refer to the section 5.3.3 in 3GPP 38.331 [8]). | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC setup Request message from the UE and sends Initial UL RRC message to O-CU with RRC setup request message in RRC container.</p> <p>Verify all the mandatory IEs of Initial UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | +| 2 | UE receives RRCsetup message for SRB1 creation. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU sends DL RRC message transfer to O-DU with RRC setup message in the RRC container to establish SRB1.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends RRC setup message to UE.</p> <p>Verify all the mandatory IEs of RRC setup as per section 6.2.2 in 3GPP Specification. [8].</p> | + +| | | | | +|---|----------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3 | UE sends RRC setup complete message over SRB1 with Registration Request as NAS payload. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the RRC setup complete message with registration request as NAS payload from UE and sends UL RRC message transfer to O-CU with RRC setup complete and Registration Request message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Initial UE Message to AMF with NAS payload as Registration Request.</p> <p>Verify all the mandatory IEs of Initial UE message as per section 9.2.5.1 of 3GPP Specification [20].</p> | +| 4 | UE receives NAS Authentication Request message from AMF with authentication parameters required for successfully authenticating the network. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives DL NAS Transport message with Authentication request as NAS payload.</p> <p>Verify that O-CU sends DL RRC Message Transfer to O-DU with NAS Authentication Request in the RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Authentication request message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> | +| 5 | UE sends NAS Authentication response message after successfully authenticating the network. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Authentication Response message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Authentication response in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Authentication Response as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 6 | UE receives NAS Security mode command message for integrity protection and ciphering. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives DL NAS Transport message with security mode command as NAS payload.</p> <p>Verify that O-CU sends DL RRC Message Transfer to O-DU with NAS Security mode command in the RRC container</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Security mode command message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> | +| 7 | UE sends NAS Security mode complete message. This message is integrity protected and ciphered. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Security mode complete message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Security mode complete message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Security mode complete as NAS payload.</p> | + +| | | | | +|----|-----------------------------------------------|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20]. | +| 8 | UE receives AS security mode command message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives Initial context setup request or DL NAS Transport from AMF with Registration accept as NAS payload.</p> <p>Verify all the mandatory IEs as per the section 9.2.2.1 or 9.2.5.2 in 3GPP Specification [20].</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU with AS security mode command message in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify the O-DU sends SecurityModeCommand to UE which contains AS integrity and Ciphering Algorithms supported by O-CU.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> | +| 9 | UE sends AS Security mode complete message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify in response of previous step, the O-DU receives SecurityModeComplete from UE.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains AS security mode complete in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | +| 10 | UE receives UE capability Enquiry message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives the UE radio capability check request from AMF to check the compatibility between UE radio capabilities and network configuration.</p> <p>O-CU can optionally request for the UE capability enquiry to the UE.</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU which contains UE capability enquiry in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends UE capability enquiry to UE to check the UE capabilities.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> | +| 11 | UE sends UE capability information message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UE capability information from UE.</p> <p>Verify all the mandatory IEs as per section 6.2.2 in 3GPP Specification [8].</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains UE capability information in the RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends UE Radio Capability Info Indication message to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.13.1 in 3GPP Specification [20].</p> | + +| | | | | +|----|-----------------------------------------------------------------------------------------------------------------------------|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | Verify PDCP-Parameters within UE-NR-Capability have “supportedROHC-Profiles” with “profile0x0002” is set to true as per 3GPP Specification [8]. | +| 12 | UE receives Registration Accept message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU sends DL RRC message transfer to O-DU which contains Registration Accept in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends DL Information Transfer message to UE with NAS Registration accept message.</p> <p>Verify all the mandatory IEs of DL information transfer message as per section 6.2.2 in 3GPP Specification [8].</p> <p>Verify 5GS “IMS voice over PS session supported over 3GPP access” bit is set to 1 within Network Feature Support.</p> | +| 13 | UE sends Registration complete message. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives the UL Information Transfer message from UE with NAS Registration complete message.</p> <p>Verify that O-DU sends UL RRC Message Transfer to O-CU with NAS Registration complete message in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Initial context setup response to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.2.2 in 3GPP Specification [20].</p> <p>Verify that O-CU sends UL NAS Transport message to AMF with Registration complete as NAS payload.</p> <p>Verify all the mandatory IEs of UL NAS Transport message as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 14 | The UE sends PDU session Establishment Request with PDU session id (refer to the section 8.3.1 in 3GPP Specification [21]). | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives UL information transfer message which contains PDU session establishment request as NAS message.</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU which contains PDU session establishment request in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends Uplink NAS transport with NAS PDU as PDU Session Establishment Request to AMF.</p> <p>Verify all the mandatory IEs as per section 9.2.5.3 in 3GPP Specification [20].</p> | +| 15 | UE receives RRC reconfiguration and PDU session establishment accept message. | <b>UE ← O-DU/<br/>O-CU</b> | <p>Verify that O-CU receives PDU Session Resource Setup Request from AMF with NAS-PDU as PDU session establishment accept.</p> <p>Verify all the mandatory IEs as per section 9.2.1.1 in 3GPP Specification [20].</p> <p>Verify that O-CU sends UE context setup request to O-DU for establishing the DRB.</p> <p>Verify all the mandatory IEs of UE context setup request as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> | + +| | | | | +|----|------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify that O-DU sends UE context setup response to O-CU after successfully establishing the DRB.</p> <p>Verify all the mandatory IEs of UE context setup response as per section 6.1.1.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends DL RRC message transfer to O-DU with RRC reconfiguration in RRC container.</p> <p>Verify all the mandatory IEs of DL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-DU sends RRC reconfiguration message to UE which contains PDU session establishment accept as NAS payload.</p> <p>Verify that UE receives RRCReconfiguration with drb-ToAddModList, pdu-Session, mappedQoS-FlowToAdd, pdcp-config with headerCompression enabled to setup 5QI 9 as per 3GPP Specification [8].</p> <ul style="list-style-type: none"> <li>• PDCP-Config <ul style="list-style-type: none"> <li>○ drb</li> <li>○ headerCompression <ul style="list-style-type: none"> <li>▪ rohc <ul style="list-style-type: none"> <li>• maxCID 15</li> <li>• profiles</li> <li>• profile0x0001 false</li> <li>• profile0x0002 true</li> <li>• profile0x0003 false</li> <li>• profile0x0004 false</li> <li>• profile0x0006 false</li> <li>• profile0x0101 false</li> <li>• profile0x0102 false</li> <li>• profile0x0103 false</li> </ul> </li> </ul> </li> </ul> </li> </ul> | +| 16 | UE sends RRC reconfiguration complete. | <b>UE → O-DU/<br/>O-CU</b> | <p>Verify that O-DU receives RRC reconfiguration complete from UE.</p> <p>Verify that O-DU sends UL RRC message transfer to O-CU with RRC reconfiguration complete in RRC container.</p> <p>Verify all the mandatory IEs of UL RRC message transfer as per section 6.1.2.3 F1-C IE handling in ORAN.WG5.C.1 [19].</p> <p>Verify that O-CU sends PDU Session Resource Setup Response to AMF over NG interface.</p> <p>Verify all the mandatory IEs as per section 9.2.1.2 in 3GPP Specification [20].</p> | +| 17 | Trigger UDP Data transfer in Uplink and downlink on the flow of 5QI 9 using any traffic generator tool or IPERF application. | <b>UE#1 ↔ O-DU/O-CU<br/>↔<br/>UPF/IMS<br/>↔ UE#2</b> | <p>Verify that end-to-end data transfer is successful by ensuring that downlink data header is compressed at the gNB and decompressed at the UE, and that uplink data header is compressed at the UE and decompressed at the gNB.</p> <p>Verify successful header compression and de-compression from gNB Wireshark and UE logs.</p> <p>Verify that the end-to-end data transfer is successful.</p> <p>Verify that enabling RoHC does not cause any performance impact.</p> <p>Note: There might be slight impact on CPU utilization due to additional processing of compression/de-compression of header when RoHC is enabled.</p> | + +## 7.86 ORAN.WG8.IOT.085: Verify successful collection and transfer of slice performance reports via E2 interface. + +### 7.86.1 Test Purpose + +The purpose of this test case is to verify successful collection and transfer of slice measurements reports on E2 interface. + +### 7.86.2 Reference Requirement + +For detailed requirements, refer to the section 13.4 in ORAN-WG8.AAD [1]. + +### 7.86.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-DU and O-CU are connected to near RT-RIC. +- SMO is pre-configured with near RT-RIC server IP address as per the data model. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +### 7.86.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. + +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.4. +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.86.5 Test Procedure + +The following table describes the test procedures to verify successful collection and transfer of slice measurements reports on E2 interface. + +**Table 7.86-1: Slice measurements on E2 interface.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|------------------------------------------------|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends Cell Configuration to O-DU. | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC and also containing all the mandatory IEs mentioned in section 11.2.1.1, Table 11-2 of [1]</p> <ul style="list-style-type: none"> <li>• PLMN Information List <ul style="list-style-type: none"> <li>◦ PLMNid = Valid configured value</li> <li>◦ S-NSSAlist</li> <li>◦ 24930</li> <li>◦ 24931</li> <li>◦ 24932</li> </ul> </li> </ul> | +| 2 | SMO sends Slice Configuration Request to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC and also containing all the mandatory IEs mentioned in section 11.2.4.2.3, Table 11-22 of [1]</p> <ul style="list-style-type: none"> <li>• S-NSSAI = 24930 <ul style="list-style-type: none"> <li>◦ RRMPolicyRatio = PRB</li> <li>◦ rRMPolicyMaxRatio = 50</li> <li>◦ rRMPolicyMinRatio = 30</li> <li>◦ rRMPolicyDedicatedRatio = 20</li> </ul> </li> </ul> | +| 3 | O-DU sends Slice Configuration Response to SMO | <b>O-DU → SMO</b> | <p>Verify that the O-DU sends a response after validating that the S-NSSAI is within the slice range and part of slice support list.</p> <p>Verify O-DU sends the slice configuration response to SMO as per below IEs mentioned in section 11.2.4.3.4 in Section 11.2 of [1]</p> <ul style="list-style-type: none"> <li>• Slice Index = 24930</li> <li>• Response = OK</li> </ul> <p>Slice configuration and prioritization is followed according to the O-RAN specification.</p> | + +| | | | | +|----|--------------------------------------------------------------------------------------------------------------------------|-------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 4 | O-DU sends the E2 Setup request to near RT-RIC server. | <b>O-DU →<br/>near RT-RIC</b> | Verify O-DU sends the E2 Setup request message to near RT-RIC server with all the mandatory IEs. | +| 5 | Near RT-RIC server sends E2 Setup Response to O-DU. | <b>O-DU ←<br/>near RT-RIC</b> | Verify near RT-RIC sends the E2 setup response to O-DU with all the mandatory IEs. | +| 6 | Cell bring-up | <b>O-DU/O-RU</b> | Verify cell bring-up is successful with the configuration that has been received from SMO.<br><br>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].<br><br>Verify O-DU sets the administrative state to UNLOCKED state. | +| 7 | Attach validation | <b>UE ← O-DU/<br/>O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration | +| 8 | Start end to end data transfer. | <b>O-DU/ O-CU<br/>→ UPF</b> | Verify end to end data is successful. | +| 9 | Near RT-RIC sends E2 Subscription Request to O-DU. | <b>O-DU ←<br/>near RT-RIC</b> | Verify near RT-RIC server sends E2 Subscription Request to O-DU with the measurements mentioned as per Section 5 of 3GPP Specification [25] in RIC Action Definition IE and Measurement Label set to Slice ID. | +| 10 | O-DU sends the E2 Subscription Response to near-RT RIC server with supported subscription items and not supported items. | <b>O-DU →<br/>near RT-RIC</b> | Verify O-DU sends the E2 Subscription Response to near-RT-RIC server with “RIC Actions Admitted List” IE filled with O-DU supported list from the SUBSCRIPTION REQUEST and “RIC Actions Not Admitted List” IE filled with O-DU non-supported list. | +| 11 | O-DU sends the periodic report to the subscribed features to near RT-RIC server through RIC INDICATION message. | <b>O-DU →<br/>near RT-RIC</b> | Verify O-DU sends the periodic report to near RT-RIC server through RIC INDICATION message as per SUBSCRIPTION REQUEST. | + +## 7.87 ORAN.WG8.IOT.086: Verify successful policy delivery and execution of slice reconfiguration via E2 interface. + +### 7.87.1 Test Purpose + +The purpose of this test case is to verify successful policy delivery and execution of slice reconfiguration via E2 interface. + +### 7.87.2 Reference Requirement + +For detailed requirements, refer to the section 13.4 in ORAN-WG8.AAD [1]. + +### 7.87.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, O-DU and O-RU is connected. + +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU is connected to O-DU. +- O-DU and O-CU are connected to near RT-RIC. +- SMO is pre-configured with near RT-RIC server IP address as per the data model. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.87.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.87.5 Test Procedure + +The following table describes the test procedures to verify successful collection and transfer of slice measurements reports on E2 interface. + +**Table 7.87-1: Slice reconfiguration on E2 interface.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | SMO sends Cell Configuration to O-DU. | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC and also containing all the mandatory IEs mentioned in section 11.2.1.1, Table 11-2 of [1]</p> <ul style="list-style-type: none"> <li>PLMN Information List <ul style="list-style-type: none"> <li>PLMNid = Valid configured value</li> <li>S-NSSAIlst</li> <li>24930</li> <li>24931</li> <li>24932</li> </ul> </li> </ul> | +| 2 | SMO sends Slice Configuration Request to O-DU | <b>O-DU ← SMO</b> | <p>Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC and also containing all the mandatory IEs mentioned in section 11.2.4.2.3, Table 11-22 of [1]</p> <ul style="list-style-type: none"> <li>S-NSSAI = 24930 <ul style="list-style-type: none"> <li>RRMPolicyRatio = PRB</li> <li>rRMPolicyMaxRatio = 50</li> <li>rRMPolicyMinRatio = 30</li> <li>rRMPolicyDedicatedRatio = 20</li> </ul> </li> </ul> | +| 3 | O-DU sends Slice Configuration Response to SMO | <b>O-DU → SMO</b> | <p>Verify that the O-DU sends a response after validating that the S-NSSAI is within the slice range and part of slice support list.</p> <p>Verify O-DU sends the slice configuration response to SMO as per below IEs mentioned in section 11.2.4.3.4 in Section 11.2 of [1]</p> <ul style="list-style-type: none"> <li>Slice Index = 24930</li> <li>Response = OK</li> </ul> <p>Slice configuration and prioritization is followed according to the O-RAN specification.</p> | +| 4 | O-DU sends the E2 Setup request to near RT-RIC server. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the E2 Setup request message to near RT-RIC server with all the mandatory IEs. | +| 5 | near RT-RIC server sends E2 Setup Response to O-DU. | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC sends the E2 setup response to O-DU with all the mandatory IEs. | +| 6 | Cell bring-up. | <b>O-DU/O-RU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DU sets the administrative state to UNLOCKED state.</p> | +| 7 | Attach validation. | <b>UE ← O-DU/O-CU</b> | Verify that UE able to attach successfully with above mentioned configuration | +| 8 | Start end to end data transfer. | <b>O-DU/O-CU → UPF</b> | Verify end to end data is successful. | + +| | | | | +|----|--------------------------------------------------------------------------------------------------------------------------|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify 30% of PRB can now be utilized for Slice #1 as reconfigured by the SMO.</p> <p>Slice configuration and prioritization is followed according to the O-RAN specification.</p> | +| 9 | near RT-RIC sends E2 Subscription Request to O-DU. | <b>O-DU ← near RT-RIC</b> | Verify near RT-RIC server sends E2 Subscription Request to O-DU with the measurements mentioned as per Section 5 of 3GPP Specification [25] in RIC Action Definition IE and Measurement Label set to Slice ID. | +| 10 | O-DU sends the E2 Subscription Response to near-RT RIC server with supported subscription items and not supported items. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the E2 Subscription Response to near-RT-RIC server with “RIC Actions Admitted List” IE filled with O-DU supported list from the SUBSCRIPTION REQUEST and “RIC Actions Not Admitted List” IE filled with O-DU non-supported list. | +| 11 | O-DU sends the periodic report to the subscribed features to near RT-RIC server through RIC INDICATION message. | <b>O-DU → near RT-RIC</b> | Verify O-DU sends the periodic report to near RT-RIC server through RIC INDICATION message as per SUBSCRIPTION REQUEST. | +| 14 | Near RT-RIC sends E2 RIC Control Request to O-DU | <b>O-DU ← near RT-RIC</b> | <p>Verify near RT-RIC sends E2 RIC Control Request to O-DU with following IEs:</p> <ul style="list-style-type: none"> <li>• Message Type</li> <li>• RIC Request ID</li> <li>• RAN Function ID</li> <li>• RIC Control Header <ul style="list-style-type: none"> <li>◦ UE ID</li> <li>◦ RIC Style ID (Control)</li> <li>◦ Control Action ID (1)</li> </ul> </li> <li>• RIC Control Message <ul style="list-style-type: none"> <li>◦ List of RAN parameters (2)</li> <li>◦ RAN Parameter ID (11)</li> <li>◦ RAN Parameter Value <ul style="list-style-type: none"> <li>▪ Min PRB Policy Ratio = 40</li> </ul> </li> <li>◦ RAN Parameter ID (12)</li> <li>◦ RAN Parameter Value <ul style="list-style-type: none"> <li>▪ Max PRB Policy Ratio = 60</li> </ul> </li> </ul> </li> </ul> | +| 15 | O-DU sends RIC Control Acknowledge to Near RT-RIC | <b>O-DU → near RT-RIC</b> | <p>Verify O-DU sends RIC CONTROL ACKNOWLEDGE to Near-RT RIC to inform Near RT-RIC that the message was received and to provide information on the outcome of the request.</p> <p>O-DU configures RRMPolicyRatio attributes when slice SLA is not achieved with the SMO configured dedicated resources.</p> | +| 16 | End to end data validation | <b>UE ↔ O-DU/O-CU</b> | <p>Verify 40% of PRB can now be utilized for Slice #1 as reconfigured by the SMO.</p> <p>Slice configuration and prioritization is followed according to the O-RAN specification.</p> | + +## 7.88 ORAN.WG8.IOT.087: Verify successful UE registration and data transmission in a Shared O-RU multi-vendor slice deployment. + +### 7.88.1 Test Purpose + +The purpose of this test case is to verify successful UE registration and data transmission when UE#1 registers with slice#1 and UE#2 registers with slice#2 in shared O-RU multi-vendor slice deployment. + +## 7.88.2 Reference Requirement + +For detailed requirements, refer to the section 13.4 in ORAN-WG8.AAD [1]. + +## 7.88.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, Shared O-RU Operator SMO, O-DU#1, O-DU#2 and Shared O-RU is connected. +- It is assumed that sharing co-ordinator has successfully configured SMO to partition Shared O-RU between multiple O-DUs. +- It is assumed that SMO configures transport systems with call home identities for O-DUs. +- It is assumed that O-RU supports SHARED-ORU-MULTI-ODU feature. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- Shared O-RU is managed entirely by primary O-DU#1 using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-CU#1 is connected to O-DU#1 (slice#1) (Refer Section 4.20.3.1.2 of [38]). +- O-CU#2 is connected to O-DU#2 (slice#2) (Refer Section 4.20.3.1.2 of [38]). +- O-CU#1 and O-CU#2 is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DUs, the NETCONF Server is started or when the O-DUs are restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU#1 and O-DU#2 have obtained end to end IP connectivity with SMO. The O-DUs shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DUs and SMO as per test case ORAN.WG8.IOT.017 (Refer Section 6.7.2 of [28]). +- O-DUs and Shared O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. + +## 7.88.4 Test Setup and Configuration + +- **DUTs:** Shared O-RU Operator SMO, O-DU#1, O-DU#2, O-CU#1, O-CU#2 and Shared O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. + +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: +- For details on the test setup refer Annex A - A.9. +- For rest of the MIB and SSB test profiles, refer B.2.1. +- For details on the SIB1 test profiles, see B.3. +- For details on the RACH test profiles, see B.6. + +## 7.88.5 Test Procedure + +The following table describes the test procedures to verify successful UE registration and data transmission in Shared O-RU multi-vendor slice deployment. + +**Table 7.88-1: Multi-vendor slice deployment** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|----------------------------------------------------------------------------|---------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Power-on gNB including O-CUs, O-DUs and Shared O-RU. | <b>O-DUs ← O-RU</b> | Verify shared O-RU sends TCP connection request to each O-DU as part of call home procedure to establish NETCONF session. | +| 2 | Secured NETCONF session establishment between O-DUs and shared O-RU. | <b>O-RU / O-DUs</b> | Verify NETCONF hello capability messages are communicated between O-DUs and shared O-RU to establish successful NETCONF session at fronthaul interface. | +| 3 | SMO sends cell configuration and partitioned carrier information to O-DUs. | <b>O-DUs ← SMO</b> | Verify the cell configuration is received from SMO to O-DUs (O1 interface).<br><br>Verify PRBs are partitioned equally within O-DU#1 and O-DU#2. | +| 4 | SMO sends Slice Configuration Request to O-DU#1. | <b>O-DU#1 ← SMO</b> | Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC and also containing all the mandatory IEs mentioned in section 11.2.4.2.3, Table 11-22 of [1] <ul style="list-style-type: none"> <li>• S-NSSAI = 24930 <ul style="list-style-type: none"> <li>◦ RRMPolicyRatio = PRB</li> <li>◦ rRMPolicyMaxRatio = 50</li> <li>◦ rRMPolicyMinRatio = 30</li> <li>◦ rRMPolicyDedicatedRatio = 20</li> </ul> </li> </ul> | +| 5 | SMO sends Slice Configuration Request to O-DU#2. | <b>O-DU#2 ← SMO</b> | Verify the following configuration is carried between SMO to O-DU-OAM-Agent (O1 interface), O-DU-OAM-Agent to MAC and also containing all the mandatory IEs mentioned in section 11.2.4.2.3, Table 11-22 of [1] <ul style="list-style-type: none"> <li>• S-NSSAI = 34930 <ul style="list-style-type: none"> <li>◦ RRMPolicyRatio = PRB</li> <li>◦ rRMPolicyMaxRatio = 50</li> <li>◦ rRMPolicyMinRatio = 30</li> <li>◦ RMPolicyDedicatedRatio = 20</li> </ul> </li> </ul> | +| 6 | O-DUs sends Slice Configuration Response to SMO | <b>O-DUs → SMO</b> | Verify O-DUs sends response after verifying S-NSSAI should be within slice range and part of slice support list. | + +| | | | | +|----|------------------------------------------------------------------------------------------------------------|------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | <p>Verify O-DUs sends the slice configuration response to SMO as per below IEs mentioned in section 11.2.4.3.4 in Section 11.2 of [1]</p> <p>Slice configuration and prioritization is followed according to the O-RAN specification.</p> | +| 7 | O-DUs sends partitioned carrier configuration to shared O-RU to establish C/U-Plane application endpoints. | <b>O-RU ← O-DUs</b> | <p>Verify O-DUs sends the partitioned carrier configuration through file download request.</p> <p>Verify O-RU downloads the file and applies the configuration. The state of O-RU is changed to INACTIVE.</p> | +| 8 | O-RU sends sync-status information to O-DUs. | <b>O-RU → O-DUs</b> | <p>Verify shared O-RU is able to achieve time synchronization with GPS.</p> <p>Verify shared O-RU shall send the sync-status as LOCKED to O-DUs.</p> | +| 9 | Activate partitioned tx/rx array carriers. | <b>O-RU ← O-DUs</b> | Verify O-DUs shall activate tx-array-carriers and rx-array-carriers in the U-Plane configuration by setting the value of the parameter "active" at tx-array-carrier element / rx-array-carrier element to "ACTIVE". | +| 10 | O-DUs sends sync-state information and set the operational state in SMO. | <b>O-DUs → SMO</b> | <p>Verify O-DUs shall send the sync-state as LOCKED to SMO.</p> <p>Verify O-DUs set the operational state to ENABLED state.</p> | +| 11 | SMO shall set the administrative state of O-DUs. | <b>O-DUs ← SMO</b> | Verify O-DUs shall set the administrative state to UNLOCKED state. | +| 12 | Cell Bring-up | <b>O-DUs/O-CU</b> | <p>Verify cell bring-up is successful with the configuration that has been received from SMO.</p> <p>O-DUs monitors the synchronization-state-change notification periodically to ensure that shared O-RU is in LOCKED state and available for CUS-plane communication, as described in section 13.1 of [24].</p> <p>Verify O-DUs sets the administrative state to UNLOCKED state.</p> | +| 13 | Verify the status of the cell. | <b>O-DUs/O-CU</b> | <p>Verify SMO shows O-CUs and O-DUs operational and newly added cell is up and RF state of shared O-RU is ACTIVE.</p> <p>Verify shared O-RU sync-state is set to LOCKED state and available for CU-plane communication.</p> <p>Verify both cells are operational.</p> | +| 14 | UE#1 Attach validation with O-DU#1 | <b>UE#1 ← O-DU#1/ O-CU#1</b> | Verify that UE able to attach successfully with partitioned O-DU#1 (slice#1). | +| 15 | UE#2 Attach validation with O-DU#2 | <b>UE#2 ← O-DU#2/ O-CU#2</b> | Verify that UE able to attach successfully with partitioned O-DU#2 (slice#2). | +| 16 | Data is started in both DL and UL for UE#1. | <b>O-DU#1/ O-CU#1 → UPF</b> | Verify that the values for "FrequencyDomainAllocation" "StartPRB" and "NoOfPRBs" in DL Scheduling Information (Refer Section 11.2.4.3.8 of [1]) align with the partitioning performed by the coordinator for O-DU#1. | + +| | | | | +|----|---------------------------------------------|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | Verify end to end data is successful for UE#1.<br><br>Slice configuration and prioritization is followed according to the O-RAN specification. | +| 17 | Data is started in both DL and UL for UE#2. | <b>O-DU#2/ O-CU#2 ↔ UPF</b> | Verify that the values for "FrequencyDomainAllocation" "StartPRB" and "NoOfPRBs" in DL Scheduling Information (Refer Section 11.2.4.3.8 of [1]) align with the partitioning performed by the coordinator for O-DU#2.<br><br>Verify end to end data is successful for UE#2.<br><br>Slice configuration and prioritization is followed according to the O-RAN specification. | + +## 7.89 ORAN.WG8.IOT.088: Verify network energy saving functionality in TRX\_CONTROL mode configured with undefined Sleep Period. + +### 7.89.1 Test Purpose + +The purpose of this test case is to verify Energy Saving functionality for undefined sleep Period in TRX\_CONTROL Mode. + +### 7.89.2 Reference Requirement + +For detailed requirements, refer to the section 7.16 and 13.6 in ORAN-WG8.AAD [1]. + +### 7.89.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, Near-RT RIC, O-CU, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-RU supports O-NES Capability and sent to O-DU through "energy-saving-capability-common-info/trx-control-capability-info" IEs. +- O-DU Connected to Near-RT RIC through E2 interface & it sends O-RU energy saving capabilities to Near-RT RIC. +- SMO is preconfigured with Near-RT RIC server IP address as per data model. +- SMO preconfigured with required AI/ML model based on collected data and share the same policies to near-RT RIC. +- O-CU is connected to 5GC through NG interface and O-CU is operational. + +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- On “E2” interface, esObjective type for O-NES policy is configured to either targetEc or esPercentage. + +## 7.89.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.89.5 Test Procedure + +The following table describes the test procedures to verify energy saving functionality with TRX\_CONTROL mode for undefined sleep period. + +**Table 7.89-1: energy saving functionality with TRX\_CONTROL for undefined sleep period.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|---------------|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell Bring-up | <b>O-CU/O-DU/O-RU</b> | <p>Verify cell bring-up is successful as per received Configuration from SMO.</p> <p>Verify O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24].</p> | + +| | | | | +|----|--------------------------------------------------------------------------------------------------------------------------------------|-------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2. | Near-RT RIC sends E2 Subscription Request to O-DU for energy saving | <b>O-DU ←<br/>Near-RT RIC</b> | Verify Near-RT RIC initiate RIC SUBSCRIPTION REQUEST to O-DU for reporting energy saving status as per below structure.<br><br>-RIC SUBSCRIPTION REQUEST> Event Trigger Definition >E2SM-CCC Event Trigger Definition Format 2> RAN Configuration Structure Name> O-CESManagementFunction | +| 3 | O-DU sends the E2 Subscription Response to near-RT RIC server with supported subscription items and not supported items. | <b>O-DU →<br/>Near-RT RIC</b> | Verify O-DU sends the E2 Subscription Response to near-RT-RIC server with “RIC Actions Admitted List” IE filled with O-DU supported list from the SUBSCRIPTION REQUEST and “RIC Actions Not Admitted List” IE filled with O-DU non-supported list. | +| 4 | O-DU sends report to the subscribed features to near RT- RIC server through RIC INDICATION message. | <b>O-DU →<br/>Near-RT RIC</b> | Verify O-DU send RIC indication to Near-RT RIC as per subscription for “O-CESManagementFunction” along with required parameter as cesSwitch/ energySavingState/ energySavingControl. | +| 5. | Near-RT RIC sends E2 Subscription Request to O-DU for collecting Measurement information | <b>O-DU ←<br/>Near-RT RIC</b> | Verify Near-RT RIC server sends E2 Subscription Request to O-DU with the measurements mentioned as per Section 5 of 3GPP Specification [25] in RIC Action Definition IE and Measurement Label like UE context & measurement metrics. | +| 6 | O-DU sends the E2 Subscription Response to near-RT RIC server with supported subscription items and not supported items. | <b>O-DU →<br/>Near-RT RIC</b> | Verify O-DU sends the E2 Subscription Response to near-RT-RIC server with “RIC Actions Admitted List” IE filled with O-DU supported list from the SUBSCRIPTION REQUEST and “RIC Actions Not Admitted List” IE filled with O-DU non-supported list. | +| 7 | O-DU sends report to the subscribed features to near RT- RIC server through RIC INDICATION message. | <b>O-DU →<br/>Near-RT RIC</b> | Verify O-DU sends the report to near RT-RIC server through RIC INDICATION message as per SUBSCRIPTION REQUEST like UE context & E2 measurement metrics. | +| 8. | Based on the collected measurement AI/ML algorithm & O-RU capability Near-RT RIC send O-NES policy to O-DU to execute energy saving. | <b>O-DU ←<br/>Near-RT RIC</b> | Verify Near-RT RIC send RIC control towards O-DU with “O-NES Policy as mentioned in above structure along with below parameters-<br><br>policyType-TRX_CONTROL<br><br>antennaMaskName -as per O-RU Capability and Near-RT RIC Decision.<br><br>antennaMask- as per O-RU Capability and Near-RT RIC Decision.<br><br>sleepMode as supported and configured.<br><br>dataDir =DL/UL as per algorithm decision<br><br>symbolMask- specifies the symbols (mask bit values of 1) during which certain antenna array elements may be put into an energy-saving mode<br><br>slotMask- the slot numbers in a frame for which the sleep mode<br><br>validDuration – This IE shouldn't include as scenario is for undefined period.<br><br>esObjective- as per defined policy. | + +| | | | | +|-----|----------------------------------------------------------------------------------------------------------------------------|-------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 9. | Based on the collected measurement, AI/ML algorithm and O-RU Capability Near-RT RIC request O-DU to execute energy saving. | <b>O-DU ←<br/>Near-RT RIC</b> | <p>Verify Near-RT RIC send RIC control message to O-DU with “O-CESManagementFunction” as per below structure</p> <p>RIC control</p> <p>>E2SM-CCC Control Message Format 2</p> <p>>RAN Configuration Structure Name</p> <p>>O-CESManagementFunction</p> <p>(Where O-CESManagementFunction includes energySavingControl as CONTROL along with attribute set as toBeEnergySaving)</p> | +| 10. | O-DU requests the decision to O-RU to initiate Energy Saving | <b>O-RU ← O-DUs</b> | <p>O-DU initiate “NES Operation Control” towards O-RU to enable Energy saving with message type as RF Channel Reconfiguration along with below parameter</p> <p>Enable-M0 to M3 as per decision.</p> <p>Activation Start Slot- Frame/sub frame/slot number</p> <p>Period- 0(as it is for undefined period)</p> <p>-O-RU configures the antennas and disable certain designated antennas and enter sleep state at sleep start time.</p> | +| 11. | O-DU informs energy Saving status to Near-RT RIC | <b>O-DU →<br/>Near-RT RIC</b> | <p>Verify O-DU Report RIC indication to Near-RT RIC as per subscription for “O-CESManagementFunction” along with required parameter as cesSwitch/ energySavingState/ energySavingControl.</p> <p>Where energySavingState as isEnergySaving.</p> <p>Follow” [37]” section 9.2.1.3 and 9.2.1.4 for reference.</p> <p>Example:</p> <p>Structure-</p> <p>RIC-Indication-Message</p> <p>>E2SM-CCC-IndicationMessageFormat2</p> <p>>>ListOfCellsReported></p> <p>>>>listOfConfigurationStructures Reported></p> <p>>>>> Change Type</p> <p>>>>> RAN Configuration Structure Name</p> <p>>>>> Values of Attributes</p> | +| 12 | O-DU Periodically Report RIC Indication to Near-RT RIC | <b>O-DU →<br/>Near-RT RIC</b> | Verify O-DU Report RIC indication to Near-RT RIC as per subscription like “O-RRMPolicyRatio”. | + +| 12 | For undefined Sleep Period Scenario, upon monitoring and based on that Near-RT RIC Request O-DU to disable Energy Saving | <b>O-DU ← Near-RT RIC</b> | <p>Verify Near-RT RIC send RIC control towards O-DU with “O-CESManagementFunction” as per below structure</p> <p>RIC control>E2SM-CCC Control Message Format 2>RAN Configuration Structure Name>O-CESManagementFunction</p> <p>(where O-CESManagementFunction includes energySavingControl as CONTROL alongwith attribute set as toBeNotEnergySaving)) follow section</p> | | | | | | | | | | | +|--------------|--------------------------------------------------------------------------------------------------------------------------|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|------------------------------|--------------|-----------------------------|--------------|-----------------------------|--------------|-----------------------------|--------------|-----------------------------| +| 13 | O-DU requests the decision to O-RU to disable Energy Saving | <b>O-RU ← O-DUs</b> | <p>O-DU initiate “NES Operation Control” towards O-RU to enable Energy saving with message type as RF Channel Reconfiguration along with below parameter</p> <p>Disable-M0 to M3 as per decision.</p> <p>Activation Start Slot- Frame/sub frame/slot number</p> <p>Acknowledgement-acknackid.</p> <p>-If sleepMode≠0 and O-RU Reported “wake-up-duration-guaranteed” as “FALSE” during Capability report then the O-DU shall wait for the number of slots indicated by the wake-up duration for the commanded sleep mode before it sends C-Plane and U-Plane traffic to the woken-up parts of the O-RU, using the correct tx-window for the first awake slot and O-RU would send Ready indication to O-DU after waking up(Step-14)</p> <p>-If sleepMode=0 and O-RU Reported “wake-up-duration-guaranteed” as “TRUE” during Capability Reporting, then the slot number indicated in the command is available for C-Plane and U-Plane traffic and O-RU shall be ready to process C-Plane and U-Plane commands.</p> <p>Supported Sleep Modes are below as per spec “[26] “Table 16.1-1</p> <table border="1"> <thead> <tr> <th></th><th>TRX_CONTROL wake-up duration</th></tr> </thead> <tbody> <tr> <td>sleep mode 0</td><td>TRXC-mode0-wake-up-duration</td></tr> <tr> <td>sleep mode 1</td><td>TRXC-mode1-wake-up-duration</td></tr> <tr> <td>sleep mode 2</td><td>TRXC-mode2-wake-up-duration</td></tr> <tr> <td>sleep mode 3</td><td>TRXC-mode3-wake-up-duration</td></tr> </tbody> </table> | | TRX_CONTROL wake-up duration | sleep mode 0 | TRXC-mode0-wake-up-duration | sleep mode 1 | TRXC-mode1-wake-up-duration | sleep mode 2 | TRXC-mode2-wake-up-duration | sleep mode 3 | TRXC-mode3-wake-up-duration | +| | TRX_CONTROL wake-up duration | | | | | | | | | | | | | +| sleep mode 0 | TRXC-mode0-wake-up-duration | | | | | | | | | | | | | +| sleep mode 1 | TRXC-mode1-wake-up-duration | | | | | | | | | | | | | +| sleep mode 2 | TRXC-mode2-wake-up-duration | | | | | | | | | | | | | +| sleep mode 3 | TRXC-mode3-wake-up-duration | | | | | | | | | | | | | +| 14 | O-RU would send Ready indication. | <b>O-RU → O-DU</b> | <p>O-RU sent Ready Indication to O-DU after waking up.</p> <p>O-RU shall send a "ready" message" to the O-DU to indicate termination of sleep. It also includes “ackid info”, as acknowledge request is included as per wakeup command.</p> | | | | | | | | | | | +| 15 | O-DU informs energy Saving status to Near-RT RIC | <b>O-DU → Near-RT RIC</b> | <p>Verify O-DU Report RIC indication to Near-RT RIC as per subscription for “O-CESManagementFunction” along with required parameter as cesSwitch/ energySavingState/ energySavingControl.</p> <p>Where energySavingState as “isNotEnergySaving”.</p> | | | | | | | | | | | + +| | | | | +|----|--------------------|--------------------|---------------------------------------------| +| 16 | Initiate UE attach | UE → O-DU/<br>O-CU | Verify that UE able to attach successfully. | +|----|--------------------|--------------------|---------------------------------------------| + +## 7.90 ORAN.WG8.IOT.089: Verify network energy saving functionality in TRX\_CONTROL mode configured with defined Sleep Period. + +### 7.90.1 Test Purpose + +The purpose of this test case is to verify Energy Saving functionality for defined sleep Period in TRX\_CONTROL Mode. + +### 7.90.2 Reference Requirement + +For detailed requirements, refer to the section 7.16 and 13.6 in ORAN-WG8.AAD [1]. + +### 7.90.3 Initial Conditions + +Following are the preconditions for this test. + +- Physical interface of DHCP(v4/v6) server, DNS server, CA/RA server, SMO, Near-RT RIC, O-CU, O-DU and O-RU is connected. +- Use the default O-CU configuration files to configure all modules (NR RRC, NR PDCP, and SDAP) in O-CU. +- O-RU is connected to O-DU. O-RU is managed entirely by O-DU using O-RAN WG4 defined hierarchical approach (Refer Section 5.1.2 of [24]). Fronthaul CU-plane data communication is verified and M-plane communication using NETCONF server is operational. +- O-RU supports O-NES Capability and sent to O-DU through “energy-saving-capability-common-info/trx-control-capability-info” IEs. +- O-DU Connected to Near-RT RIC through E2 interface & it sends O-RU energy saving capabilities to Near-RT RIC. +- SMO is preconfigured with Near-RT RIC server IP address as per data model. +- SMO preconfigured with required AI/ML model based on collected data and share the same policies to near-RT RIC. +- O-CU is connected to 5GC through NG interface and O-CU is operational. +- It is assumed that when Power-ON the O-DU, the NETCONF Server is started or when the O-DU is restarted, the NETCONF Server is restarted. +- NETCONF Client is operational. +- The O-DU have obtained end to end IP connectivity between O-DU and SMO. The O-DU shall support either IPv4 or IPv6. +- The PnfRegistration is successful with TLS secure connection is established between O-DU and SMO as per test case ORAN.WG8.IOT.017. + +- O-DU and O-RU to time synchronize using one of O-RAN Fronthaul Transport Synchronization profiles (LLS-C1 to LLS-C4) defined by O-RAN WG4 specification [26]. +- On “E2” interface, esObjective type for O-NES policy is configured to either targetEc or esPercentage. + +## 7.90.4 Test Setup and Configuration + +- **DUTs:** SMO, O-DU, O-CU and O-RU. +- **Testing tools:** are required for this test scenario. +- Test UEs or UE emulator which can support NR. +- 5G-NR O-RU or O-RU emulator. +- 5G Core or CN emulator used which supports N1, N2 and HTTP messages. +- Protocol Analyzer is used to record and observe F1AP, NGAP, FH-eCPRI, FAPI, NAS, HTTP2, PFCP protocol content. +- Configuration: + - For details on the test setup refer Annex A - A.4. + - For rest of the MIB and SSB test profiles, refer B.2.1. + - For details on the SIB1 test profiles, see B.3. + - For details on the RACH test profiles, see B.6. + +## 7.90.5 Test Procedure + +The following table describes the test procedures to verify energy saving functionality with TRX\_CONTROL mode for defined sleep period. + +**Table 7.90-1: energy saving functionality with TRX\_CONTROL for defined sleep period.** + +| St. | Procedure | Msg Flow | Expected Output | +|-----|--------------------------------------------------------------------------------------------------------------------------|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 1 | Cell Bring-up | <b>O-CU/O-DU/O-RU</b> | Verify cell bring-up is successful as per received Configuration from SMO.<br><br>Verify O-DU monitors the synchronization-state-change notification periodically to ensure that O-RU is in LOCKED state and available for CU-plane communication, as described in section 13.1 of [24]. | +| 2. | Near RT-RIC sends E2 Subscription Request to O-DU for energy saving | <b>O-DU ← Near-RT RIC</b> | Verify Near-RT RIC initiates RIC SUBSCRIPTION REQUEST to O-DU for reporting energy saving status as per below structure.<br><br>-RIC SUBSCRIPTION REQUEST> <i>Event Trigger Definition</i> >E2SM-CCC Event Trigger Definition Format 2> RAN Configuration Structure Name> O-CESManagementFunction | +| 3 | O-DU sends the E2 Subscription Response to near-RT RIC server with supported subscription items and not supported items. | <b>O-DU → Near-RT RIC</b> | Verify O-DU sends the E2 Subscription Response to near-RT-RIC server with “RIC Actions Admitted List” IE filled with O-DU supported list from the | + +| | | | | +|----|---------------------------------------------------------------------------------------------------------------------------------------|-------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | | SUBSCRIPTION REQUEST and “RIC Actions Not Admitted List” IE filled with O-DU non-supported list. | +| 4 | O-DU sends report to the subscribed features to near RT-RIC server through RIC INDICATION message. | <b>O-DU →<br/>Near-RT RIC</b> | Verify O-DU send RIC indication to Near-RT RIC as per subscription for “O-CESManagementFunction” along with required parameter as cesSwitch/ energySavingState/ energySavingControl. | +| 5. | near RT-RIC sends E2 Subscription Request to O-DU for collecting Measurement information | <b>O-DU ←<br/>Near-RT RIC</b> | Verify near RT-RIC server sends E2 Subscription Request to O-DU with the measurements mentioned as per Section 5 of 3GPP Specification [25] in RIC Action Definition IE and Measurement Label. | +| 6 | O-DU sends the E2 Subscription Response to near-RT RIC server with supported subscription items and not supported items. | <b>O-DU →<br/>Near RT RIC</b> | Verify O-DU sends the E2 Subscription Response to near-RT-RIC server with “RIC Actions Admitted List” IE filled with O-DU supported list from the SUBSCRIPTION REQUEST and “RIC Actions Not Admitted List” IE filled with O-DU non-supported list. | +| 7 | O-DU sends report to the subscribed features to near RT-RIC server through RIC INDICATION message. | <b>O-DU →<br/>Near-RT RIC</b> | Verify O-DU sends the report to near RT-RIC server through RIC INDICATION message as per SUBSCRIPTION REQUEST. | +| 8 | Based on the collected measurement /AI/ML algorithm & O-RU capability Near-RT RIC send O-NES policy to O-DU to execute energy saving. | <b>O-DU ←<br/>Near-RT RIC</b> | <p>Verify Near-RT RIC send RIC control towards O-DU with “O-NES Policy as mentioned in above structure along with below parameters-</p> <p>policyType-TRX_CONTROL</p> <p>antennaMaskName -as per O-RU Capability and Near-RT RIC Decision.</p> <p>antennaMask- as per O-RU Capability and Near-RT RIC Decision.</p> <p>sleepMode as supported and configured.</p> <p>dataDir =DL/UL/ as per algorithm decision</p> <p>symbolMask- specifies the symbols (mask bit values of 1) during which certain antenna array elements may be put into an energy-saving mode</p> <p>slotMask- the slot numbers in a frame for which the sleep mode</p> <p>validDuration – time duration in unit of 10ms for which the sleep mode to be valid</p> <p>esObjective- as per defined policy.</p> | +| 9. | Based on the collected measurement & AI/ML algorithm, Near-RT RIC request O-DU to execute energy saving. | <b>O-DU ←<br/>Near-RT RIC</b> | <p>Verify Near-RT RIC send RIC control message to O-DU with “O-CESManagementFunction” as per below structure</p> <p>RIC control>E2SM-CCC Control Message Format<br/>2>RAN Configuration Structure Name>O-CESManagementFunction</p> <p>(Where O-CESManagementFunction includes energySavingControl as CONTROL along with attribute set as toBeEnergySaving)</p> | + +| 10. | O-DU request decision to O-RU to initiate Energy Saving | <b>O-RU ← O-DU</b> | <p>-O-DU initiate “NES Operation Control” towards O-RU to enable Energy saving with message type as RF Channel Reconfiguration along with below parameter</p> <p>Enable-M0 to M3 as per decision.</p> <p>Activation Start Slot- Frame/sub frame/slot number</p> <p>Period- number of slots for which the command configuration shall be valid</p> <p>Acknowledgement- acknackid</p> <p>-O-RU configures the antennas and disable certain designated antennas and enter sleep state at sleep start time.</p> <p>Supported Sleep Modes are below as per spec “[26]” <b>“Table 16.1-1”</b></p> <table border="1"> <thead> <tr> <th></th> <th><b>TRX_CONTROL wake-up duration</b></th> </tr> </thead> <tbody> <tr> <td>sleep mode 0</td> <td>TRXC-mode0-wake-up-duration</td> </tr> <tr> <td>sleep mode 1</td> <td>TRXC-mode1-wake-up-duration</td> </tr> <tr> <td>sleep mode 2</td> <td>TRXC-mode2-wake-up-duration</td> </tr> <tr> <td>sleep mode 3</td> <td>TRXC-mode3-wake-up-duration</td> </tr> </tbody> </table> | | <b>TRX_CONTROL wake-up duration</b> | sleep mode 0 | TRXC-mode0-wake-up-duration | sleep mode 1 | TRXC-mode1-wake-up-duration | sleep mode 2 | TRXC-mode2-wake-up-duration | sleep mode 3 | TRXC-mode3-wake-up-duration | +|--------------|---------------------------------------------------------|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|-------------------------------------|--------------|-----------------------------|--------------|-----------------------------|--------------|-----------------------------|--------------|-----------------------------| +| | <b>TRX_CONTROL wake-up duration</b> | | | | | | | | | | | | | +| sleep mode 0 | TRXC-mode0-wake-up-duration | | | | | | | | | | | | | +| sleep mode 1 | TRXC-mode1-wake-up-duration | | | | | | | | | | | | | +| sleep mode 2 | TRXC-mode2-wake-up-duration | | | | | | | | | | | | | +| sleep mode 3 | TRXC-mode3-wake-up-duration | | | | | | | | | | | | | +| 11. | O-DU inform energy Saving status to Near-RT RIC | <b>O-DU → Near-RT RIC</b> | <p>Verify O-DU Report RIC indication to Near-RT RIC as per subscription for “O-CESManagementFunction” along with required parameter as cesSwitch/ energySavingState/ energySavingControl.</p> <p>Where energySavingState as isEnergySaving.</p> <p>Follow” [37]” section 9.2.1.3 and 9.2.1.4 for reference.</p> <p>Example:</p> <p>Structure-</p> <p>RIC-Indication-Message</p> <p>>E2SM-CCC-IndicationMessageFormat2</p> <p>>>ListOfCellsReported></p> <p>>>>listOfConfigurationStructures Reported></p> <p>>>>> Change Type</p> <p>>>>> RAN Configuration Structure Name</p> <p>>>>> Values of Attributes</p> | | | | | | | | | | | + +| | | | | +|----|-------------------------------------------------------------------|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 12 | At expiry of sleep duration, O-RU comes out of energy saving mode | <b>O-RU</b> | <p>-If sleepMode≠0 and O-RU Reported “wake-up-duration-guaranteed” as “FALSE” during Capability report then the O-DU shall wait for the number of slots indicated by the wake-up duration for the commanded sleep mode before it sends C-Plane and U-Plane traffic to the woken-up parts of the O-RU, using the correct tx-window for the first awake slot and O-RU would send Ready indication to O-DU after waking up(Step-13)</p> <p>-If sleepMode=0 and O-RU Reported “wake-up-duration-guaranteed” as “TRUE” during Capability Reporting then the slot number indicated in the command is available for C-Plane and U-Plane traffic and O-RU shall be ready to process C-Plane and U-Plane commands.</p> | +| 13 | O-RU would sent Ready indication. | <b>O-RU → O-DU</b> | O-RU sent Ready Indication to O-DU after waking up. | +| 14 | O-DU inform energy Saving status to Near-RT RIC | <b>O-DU → Near-RT RIC</b> | <p>Verify O-DU Report RIC indication to Near-RT RIC as per subscription for “O-CESManagementFunction” along with required parameter as cesSwitch/ energySavingState/ energySavingControl.</p> <p>Where energySavingState as isNotEnergySaving.</p> | +| 15 | Initiate UE attach | <b>UE → O-DU/ O-CU</b> | Verify that UE able to attach successfully. | + +## Annex A (informative) + +### Test Setup + +This section covers the test setup architectures and configurations. + +#### A.1 Test Setup 1: End to End OTA architecture using commercial UE + +**Figure A.1- 1: Test Setup 1 - End to End OTA architecture using commercial UE** + +![Diagram of Test Setup 1: End to End OTA architecture using commercial UE. The diagram shows a mobile phone connected to an O-RU/O-RU Emulator (represented by a radio tower icon). This is connected via the Front haul to the O-DU. The O-DU is connected via the Mid haul to a cloud representing the O-CU-CP and O-CU-UP. The cloud is connected via the Back haul to a box labeled 'Simulated core N/W'.](3c31cea4b732acd6215098d416b266ce_img.jpg) + +``` + +graph LR + UE[UE] --- FH[Front haul] --- ORE[O-RU/ O-RU Emulator] + ORE --- MH[Mid haul] --- ODU[O-DU] + ODU --- BH[Back haul] --- Cloud((O-CU-CP, O-CU-UP)) + Cloud --- SCN[Simulated core N/W] + +``` + +Diagram of Test Setup 1: End to End OTA architecture using commercial UE. The diagram shows a mobile phone connected to an O-RU/O-RU Emulator (represented by a radio tower icon). This is connected via the Front haul to the O-DU. The O-DU is connected via the Mid haul to a cloud representing the O-CU-CP and O-CU-UP. The cloud is connected via the Back haul to a box labeled 'Simulated core N/W'. + +## A.2 Test Setup 2: End to End OTA architecture using UE Simulator/Emulator + +Figure A.2- 1: Test Setup 2 - End to End OTA architecture using UE Simulator/Emulator + +![Figure A.2- 1: Test Setup 2 - End to End OTA architecture using UE Simulator/Emulator. The diagram shows a UE Simulator (green box) connected to an O-RU/O-RU Emulator (red box with a tower icon). This is connected via a Front haul to an O-DU (red box). The O-DU is connected via a Mid haul to a cloud containing O-CU-CP and O-CU-UP (red boxes). This cloud is connected via a Back haul to a Simulated core N/W (blue box).](76460bf5e99e0d41865041a880427922_img.jpg) + +Figure A.2- 1: Test Setup 2 - End to End OTA architecture using UE Simulator/Emulator. The diagram shows a UE Simulator (green box) connected to an O-RU/O-RU Emulator (red box with a tower icon). This is connected via a Front haul to an O-DU (red box). The O-DU is connected via a Mid haul to a cloud containing O-CU-CP and O-CU-UP (red boxes). This cloud is connected via a Back haul to a Simulated core N/W (blue box). + +## A.3 Test Setup 3: Simulated CU and CN architecture + +Figure A.3- 1: Test Setup 3 - Simulated CU and CN architecture + +![Figure A.3- 1: Test Setup 3 - Simulated CU and CN architecture. The diagram shows a mobile phone icon connected to an O-RU/O-RU Emulator (red box with a tower icon). This is connected via a Front haul to an O-DU (red box). The O-DU is connected via a Mid haul to a cloud containing a Simulated O-CU (red box). This cloud is connected via a Back haul to a Simulated core N/W (blue box).](05c823a95fefe1f4a960e3b29daafb3e_img.jpg) + +Figure A.3- 1: Test Setup 3 - Simulated CU and CN architecture. The diagram shows a mobile phone icon connected to an O-RU/O-RU Emulator (red box with a tower icon). This is connected via a Front haul to an O-DU (red box). The O-DU is connected via a Mid haul to a cloud containing a Simulated O-CU (red box). This cloud is connected via a Back haul to a Simulated core N/W (blue box). + +## A.4 Test Setup 4: O1 and E2 interface for Remote O-RU connected to O-DU architecture + +Figure A.4- 1: Test Setup 4 - O1 and E2 interface for Remote O-RU connected to O-DU architecture + +![Figure A.4- 1: Test Setup 4 - O1 and E2 interface for Remote O-RU connected to O-DU architecture. The diagram shows a UE (mobile phone icon) connected to an O-RU (blue box with a tower icon). The O-RU is connected via a Front haul to an O-DU (blue box). The O-DU is connected via a Mid haul to an O-CU (blue box). The O-CU is connected via a Back haul to a 5G CN (blue box). Above the O-DU and O-CU is an SMO (Service Management and Orchestration) block containing a non-RT-RIC and a Near RT-RIC. The non-RT-RIC is connected to the Near RT-RIC via an A1 interface. The O-DU is connected to the non-RT-RIC via an O1 interface (red arrow) and to the Near RT-RIC via an E2 interface (green arrow). The O-CU is connected to the Near RT-RIC via an E2 interface (green arrow).](25e235d77c6d1eb1f196d40689cad567_img.jpg) + +Figure A.4- 1: Test Setup 4 - O1 and E2 interface for Remote O-RU connected to O-DU architecture. The diagram shows a UE (mobile phone icon) connected to an O-RU (blue box with a tower icon). The O-RU is connected via a Front haul to an O-DU (blue box). The O-DU is connected via a Mid haul to an O-CU (blue box). The O-CU is connected via a Back haul to a 5G CN (blue box). Above the O-DU and O-CU is an SMO (Service Management and Orchestration) block containing a non-RT-RIC and a Near RT-RIC. The non-RT-RIC is connected to the Near RT-RIC via an A1 interface. The O-DU is connected to the non-RT-RIC via an O1 interface (red arrow) and to the Near RT-RIC via an E2 interface (green arrow). The O-CU is connected to the Near RT-RIC via an E2 interface (green arrow). + +## A.5 Test Setup 5: O1 and E2 interface for co-located O-RU and O-DU architecture + +Figure A.5- 1: Test Setup 5 - O1 and E2 interface for co-located O-RU and O-DU architecture + +![Figure A.5- 1: Test Setup 5 - O1 and E2 interface for co-located O-RU and O-DU architecture. The diagram shows a UE connected to an O-RU/O-DU. The O-RU/O-DU is connected to an O-CU via a Mid haul interface. The O-CU is connected to a 5G CN via a Back haul interface. The O-RU/O-DU is also connected to an SMO (Service Management and Orchestration) block. The SMO contains a non-RT-RIC and a Near RT-RIC. The O-RU/O-DU is connected to the SMO via an O1 interface. The O-CU is connected to the SMO via an O1 interface. The SMO is connected to the O-CU via an A1 interface. The O-RU/O-DU is also connected to the SMO via an E2 interface.](528a239c2039db243a9c2cf4150dfdcf_img.jpg) + +Figure A.5- 1: Test Setup 5 - O1 and E2 interface for co-located O-RU and O-DU architecture. The diagram shows a UE connected to an O-RU/O-DU. The O-RU/O-DU is connected to an O-CU via a Mid haul interface. The O-CU is connected to a 5G CN via a Back haul interface. The O-RU/O-DU is also connected to an SMO (Service Management and Orchestration) block. The SMO contains a non-RT-RIC and a Near RT-RIC. The O-RU/O-DU is connected to the SMO via an O1 interface. The O-CU is connected to the SMO via an O1 interface. The SMO is connected to the O-CU via an A1 interface. The O-RU/O-DU is also connected to the SMO via an E2 interface. + +## A.6 Test Setup 6: Setup for inter O-DU HO within an O-CU + +Figure A.6- 1: Test Setup 6 - inter O-DU HO within an O-CU + +![Figure A.6- 1: Test Setup 6 - inter O-DU HO within an O-CU. The diagram shows two O-RU blocks connected to two O-DU blocks via Front haul interfaces. The O-DU blocks are connected to an O-CU block via Mid haul interfaces. The O-CU block is connected to a 5G CN block via a Back haul interface. The O-CU block is also connected to an SMO block via an O1 interface. The SMO block is connected to the O-CU block via an O1 interface. The O-CU block is also connected to the SMO block via an O1 interface.](b535459e6b0692d014e61f3acf918e1b_img.jpg) + +Figure A.6- 1: Test Setup 6 - inter O-DU HO within an O-CU. The diagram shows two O-RU blocks connected to two O-DU blocks via Front haul interfaces. The O-DU blocks are connected to an O-CU block via Mid haul interfaces. The O-CU block is connected to a 5G CN block via a Back haul interface. The O-CU block is also connected to an SMO block via an O1 interface. The SMO block is connected to the O-CU block via an O1 interface. The O-CU block is also connected to the SMO block via an O1 interface. + +## A.7 Test Setup 7: Setup for O-DU Timing Synchronization + +Figure A.7- 1: Test Setup 7 – O-DU Timing Synchronization + +![Figure A.8- 1: Test Setup 8 – vO-DU and vO-CU Cloudification. This diagram illustrates the clock synchronization architecture for vO-DU and vO-CU. It shows two main processing blocks, each containing a PHC (Physical Hardware Clock) and a NIC (Network Interface Card). The left block is connected to a GNSS Receiver via a dashed line labeled '1PPS'. The right block is connected to a 'System Clock' block. The 'System Clock' block is connected to the 'PHC' of the right block via a 'PHC2Sys' interface. The 'System Clock' block is also connected to the 'O-RAN FH Lib' (O-RAN Fronthaul Library) block via a 'Clock_gettime()' interface. The 'O-RAN FH Lib' block is connected to the 'DPDK' (Data Plane Development Kit) block, which is in turn connected to the 'PHC' of the left block. The 'PHC' of the left block is connected to the 'Fronthaul' interface. The 'PHC' of the right block is connected to the 'Backhaul' interface, which is also connected to a 'PTP4L' interface.](87058cc45705b75b05eec495154e06b6_img.jpg) + +Figure A.8- 1: Test Setup 8 – vO-DU and vO-CU Cloudification. This diagram illustrates the clock synchronization architecture for vO-DU and vO-CU. It shows two main processing blocks, each containing a PHC (Physical Hardware Clock) and a NIC (Network Interface Card). The left block is connected to a GNSS Receiver via a dashed line labeled '1PPS'. The right block is connected to a 'System Clock' block. The 'System Clock' block is connected to the 'PHC' of the right block via a 'PHC2Sys' interface. The 'System Clock' block is also connected to the 'O-RAN FH Lib' (O-RAN Fronthaul Library) block via a 'Clock\_gettime()' interface. The 'O-RAN FH Lib' block is connected to the 'DPDK' (Data Plane Development Kit) block, which is in turn connected to the 'PHC' of the left block. The 'PHC' of the left block is connected to the 'Fronthaul' interface. The 'PHC' of the right block is connected to the 'Backhaul' interface, which is also connected to a 'PTP4L' interface. + +## A.8 Test Setup 8: Setup for vO-DU and vO-CU Cloudification + +**Figure A.8- 1: Test Setup 8 – vO-DU and vO-CU Cloudification** + +![Figure A.8- 1: Test Setup 8 – vO-DU and vO-CU Cloudification. This diagram illustrates the cloudification setup for vO-DU and vO-CU. A mobile phone is connected to an 'O-RU/ O-RU Emulator' block via a 'Front haul' interface. The 'O-RU/ O-RU Emulator' block is connected to a cloud representing the vO-DU and vO-CU. Inside the cloud, there are two blocks: 'vO-CU-CP' (Control Plane) and 'vO-CU-UP' (User Plane). The cloud is connected to a 'Simulated core N/W' block via a 'Back haul' interface.](daf5732416b700788d46fbfa0d198c77_img.jpg) + +Figure A.8- 1: Test Setup 8 – vO-DU and vO-CU Cloudification. This diagram illustrates the cloudification setup for vO-DU and vO-CU. A mobile phone is connected to an 'O-RU/ O-RU Emulator' block via a 'Front haul' interface. The 'O-RU/ O-RU Emulator' block is connected to a cloud representing the vO-DU and vO-CU. Inside the cloud, there are two blocks: 'vO-CU-CP' (Control Plane) and 'vO-CU-UP' (User Plane). The cloud is connected to a 'Simulated core N/W' block via a 'Back haul' interface. + +## A.9 Test Setup 9: Setup for Single Operator Solution for Shared O-RU + +**Figure A.9- : Test Setup 9 – Single Operator Solution for Shared O-RU** + +![Network architecture diagram showing SMO, O-CU, Near-RT RIC, Hierarchical O-DU, and O-RU components with their interconnections.](db41f40802b531c10dfcb105c57e1a36_img.jpg) + +The diagram illustrates the O-RAN architecture. At the top is the SMO (Service Based Interface) block, which contains the text 'Co-ordination of O-RU resources for O-DU#1 and O-DU#2'. Below SMO are two O-CU blocks, each containing 'O-CU UP' and 'O-CU-CP'. These are connected to a central Near-RT RIC block. The O-CU blocks are also connected to two Hierarchical O-DU blocks (O-DU#1 and O-DU#2). The O-DU blocks are connected to the O-RU block at the bottom, which contains 'Carriers' and 'O-RU'. The connections are labeled with interfaces: O1, E2, F1-c/u, and Open FH M-Plane (sudo) / Open FH CUS-Plane. + +Network architecture diagram showing SMO, O-CU, Near-RT RIC, Hierarchical O-DU, and O-RU components with their interconnections. + +## Annex B (informative) + +### Test Profile 1: Throughput Test + +#### B.1 FTP Settings + +TCP data transfer depends on the following parameters: + +- TCP window size +- Number of stream (default: 4 streams). +- TCP maximum segment size (MSS). MSS is 1452 bytes (1492-byte MTU). + +##### B.1.1 UDP Settings + +UDP data transfer depends on the following parameters: + +- The length of buffers to read or write. For UDP default is 1470 Bytes +- UDP bandwidth in bits/sec. Default is 1 Mbit/sec. + +### B.2 MIB and SSB configuration + +#### B.2.1 MIB and SSB for FR1 + +**Table B.2-1: MIB and SSB for FR1** + +| MIB | | | +|-----------------------------|-------------------------------------|------------------------------| +| Parameter | Possible Values | Recommended Values (Phase 1) | +| subCarrierSpacingCommon | ENUMERATED {scs15or60, scs30or120}, | 1 | +| ssb-SubcarrierOffset | INTEGER (0..15), | 15 | +| dmrs-TypeA-Position | ENUMERATED {pos2, pos3}, | NA | +| pdccch-ConfigSIB1 | INTEGER (0..255), | NA | +| > controlResourceSetZero | | | +| > searchSpaceZero | | | +| cellBarred | ENUMERATED {barred, notBarred}, | 1 | +| intraFreqReselection | ENUMERATED {allowed, notAllowed}, | 0 | +| Multiplexing | TDD/FDD | FDD | +| SSB Pattern (time-freq) | | | +| | | | +| ssb-PositionsInBurst | | 10000000... | +| ssb-periodicityServingCell- | | ms20 | +| absoluteFrequencySSB | | according to bandindicator | + +## B.2.2 MIB and SSB for FR2 + +**Table B.2-2: MIB and SSB for FR2** + +| MIB | | | +|--------------------------|-------------------------------------|-------------------------------------| +| Parameter | Possible Values | Recommended Values (Phase 1) | +| subCarrierSpacingCommon | ENUMERATED {scs15or60, scs30or120}, | 1 | +| ssb-SubcarrierOffset | INTEGER (0..11), | As per freq domain resources of SSB | +| dmrs-TypeA-Position | ENUMERATED {pos2, pos3}, | NA | +| pdccch-ConfigSIB1 | INTEGER (0..255), | NA | +| > controlResourceSetZero | | | +| > searchSpaceZero | | | + +| | | | +|--------------------------------|-----------------------------------|----------------------------------------------------------------------------| +| cellBarred | ENUMERATED {barred, notBarred}, | 1 | +| intraFreqReselection | ENUMERATED {allowed, notAllowed}, | 0 | +| Multiplexing | TDD | TDD | +| <b>SSB Pattern (time-freq)</b> | | | +| | | | +| ssb-PositionsInBurst | | SSB-PositionInBurst<br>inOneGroup<br>11111111<br>GroupPresence<br>11111111 | +| ssb-periodicityServingCell | | ms40 | +| absoluteFrequencySSB | | according to<br>bandindicator | + +### B.3 SIB1 Configuration + +Table B.3-1: SIB1 + +| | | | Default Values<br>(Proposed) | +|---------------------|----------------------|------------|------------------------------| +| SI-SchedulingInfo | | | | +| | si-WindowLength | ENUMERATED | s20 | +| SchedulingInfo | | | | +| | si-Periodicity | ENUMERATED | rf16 | +| SI-RequestConfig::= | | | | +| | ssb-perRACH-Occasion | ENUMERATED | one | + +### B.4 PUCCH Support- Short PUCCH Format Configuration + +Table B.4-1: PUCCH Support- Short PUCCH Format + +| <b>PUCCH Format0</b> | | +|----------------------|-----| +| format | 0 | +| initialCyclicShift | 0,3 | +| nrofSymbols | 1 | +| startingSymbolIndex | 13 | +| <b>PUCCH Format2</b> | | +| format | 2 | +| nrofSymbols | 1 | + +| | | +|---------------------|----| +| startingSymbolIndex | 13 | +| Number of PRB | 3 | + +## B.5 Downlink Data Delivery Status Reporting + +Refer to the DL DATA DELIVERY STATUS frame format defined in section 5.5.2.2 in 3GPP Specification [10] for more details. All parameters are not mandatory. The desired buffer size for the data radio bearer parameter is required to inform to CU. + +**Table B.5-1: Downlink Data Delivery Status Reporting** + +| Bits | | | | | | | | Number of Octets | +|--------------------------------------------------------------|---|---|---|------------------------------------|----------------------------------|----------------------------------------|--------------------|--------------------------------------------------| +| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | | +| PDU Type (=1) | | | | Highest Transmitted NR PDCP SN Ind | Highest Delivered NR PDCP SN Ind | Final Frame Ind. | Lost Packet Report | 1 | +| Spare | | | | Data rate Ind. | Retransmitted NR PDCP SN Ind | Delivered Retransmitted NR PDCP SN Ind | Cause Report | 1 | +| Desired buffer size for the data radio bearer | | | | | | | | 4 | +| Desired Data Rate | | | | | | | | 0 or 4 | +| Number of lost NR-U Sequence Number ranges reported | | | | | | | | 0 or 1 | +| Start of lost NR-U Sequence Number range | | | | | | | | 0 or (6* Number of reported lost NR-U SN ranges) | +| End of lost NR-U Sequence Number range | | | | | | | | | +| Highest successfully delivered NR PDCP Sequence Number | | | | | | | | 0 or 3 | +| Highest transmitted NR PDCP Sequence Number | | | | | | | | 0 or 3 | +| Cause Value | | | | | | | | 0 or 1 | +| Successfully delivered retransmitted NR PDCP Sequence Number | | | | | | | | 0 or 3 | +| Retransmitted NR PDCP Sequence Number | | | | | | | | 0 or 3 | +| Padding | | | | | | | | 0-3 | + +## B.6 RACH Configuration + +**Table B.6-1: RACH Configuration** + +| RACH IEs (3GPP) | RACH IEs (Config file) | RACHConfig1 (Format 0) | RACHConfig1 (Format C2) | RACHConfig2 (Format B4) | +|-------------------------------------------|-----------------------------|------------------------|-------------------------|-------------------------| +| RACH-ConfigDedicated | | | | | +| RACH-ConfigCommon | | | | | +| rach-ConfigGeneric | | | | | +| > prach-ConfigurationIndex | PrachConfigIndex | 1 | 190 | 160 | +| > msg1-FDM | PrachMsg1Fdm | 1 | | | +| > msg1-FrequencyStart | PrachMsg1FreqStartRb | 0 | | | +| > zeroCorrelationZoneConfig | ZeroCorrelationZoneConfig | Default | | | +| > preambleReceivedTargetPower | preambleReceivedTargetPower | Default | | | +| > preambleTransMax | preambleTransMax | Default | | | +| > powerRampingStep | powerRampingStep | Default | | | +| > ra-ResponseWindow | RaResponseWindow | sl4 | | | +| totalNumberOfRA-Preambles | TotalRaPreambles | 63 | | | +| ssb-perRACH-OccasionAndCB-PreamblesPerSSB | SsbPerRachOcc | 3 | | | +| | TotalCbPreamblesPerSsb | 44 | | | +| msg1-SubcarrierSpacing | PrachScs | 30KHz | | | +| restrictedSetConfig | PrachRestrictSet | unrestrictedSet | | | + +## B.7 Throughput Configuration + +**Table B.7-1: Throughput Configuration** + +| TDD-UL-DL-ConfigCommon | | Default | +|-------------------------------|--------------------------------|---------| +| referenceSubcarrierSpacing | SubcarrierSpacing, | 30 KHz | +| pattern1 | TDD-UL-DL-Pattern, | | +| TDD-UL-DL-Pattern ::= | | | +| dl-UL-TransmissionPeriodicity | | ms2p5 | +| nrofDownlinkSlots | INTEGER (0..maxNrofSlots), | 3 | +| nrofDownlinkSymbols | INTEGER (0..maxNrofSymbols-1), | 10 | +| nrofUplinkSlots | INTEGER (0..maxNrofSlots), | 1 | +| nrofUplinkSymbols | INTEGER (0..maxNrofSymbols-1), | 2 | + +Time slot configuration: DDDSU + +Bandwidth: 100 MHz + +| Downlink | Suggested | | Uplink | Config | +|---------------------------|-----------|--|---------------------------|--------| +| U | 1 | | U | 1 | +| Max RBs | 275 | | Max RBs | 275 | +| Number of layers | 2 | | Number of layers | 2 | +| Code rate for DL (MCS 28) | 5.5547 | | Code rate for UL (MCS 28) | 5.5547 | + +| | | | | +|------------------------------------|-------------------|------------------------------------|----------------| +| Number of Subcarriers | 12 | Number of Subcarriers | 12 | +| Slot config per sec | 400 | Slot config per sec | 400 | +| Lmax | 2 | Lmax | 2 | +| PDCCH aggregation level | 4 | PUCCH | 1 | +| Number of Res per CCEs | 72 | Number of Res per CCEs | 72 | +| SSB (Res) | 48 | | | +| DMRS (1 sym) | 3300 | DMRS (3Sym) | 9900 | +| PDCCH Res | 1152 | PUCCH Res | 6600 | +| Over head Res | 4500 | Over head Res | 16500 | +| Number of Total REs | 68640 | Number of total Res | 42240 | +| Available RBs for DL data transfer | 64140 | Available RBs for UL data transfer | 25740 | +| <b>DL Throughput</b> | <b>712.556916</b> | <b>UL Throughput</b> | <b>285.956</b> | + +## B.8 CSI-RS configuration + +Table B.8-1: CSI-RS configuration + +| CSI-RS IEs | Possible values | Config 1 | Config 2 | Config 3 | +|-------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------|----------------|----------------| +| resourceMapping | | | | | +| > frequencyDomainAllocation | row1, row2, row4, other | row1 (0001) | other (000001) | other (000001) | +| > nrofPorts | ENUMERATED {p1,p2,p4,p8,p12,p16,p24,p32} | p1 | p2 | p2 | +| > firstOFDMSymbolInTimeDomain | INTEGER (0..13) | 13 | 13 | 13 | +| > cdm-Type | ENUMERATED {noCDM, fd-CDM2, cdm4-FD2-TD2, cdm8-FD2-TD4} | noCDM | noCDM | fd-CDM2 | +| > density | dot5 ENUMERATED {evenPRBs, oddPRBs}, one, three, spare | 3 | 1 | 1 | +| powerControlOffset | INTEGER (-8..15) | 0 | 0 | 0 | +| powerControlOffsetSS | ENUMERATED {db-3, db0, db3, db6} | db0 | db0 | db0 | +| periodicityAndOffset | slots4 INTEGER (0..3),<br>slots5 INTEGER (0..4),<br>slots8 INTEGER (0..7),<br>slots10 INTEGER (0..9),<br>slots16 INTEGER (0..15),<br>slots20 INTEGER (0..19),<br>slots32 INTEGER (0..31),<br>slots40 INTEGER (0..39),<br>slots64 INTEGER (0..63),<br>slots80 INTEGER (0..79),<br>slots160 INTEGER (0..159),<br>slots320 INTEGER (0..319),<br>slots640 INTEGER (0..639) | slot20 | slot40 | Slot80 | + +## B.9 SRS configuration + +Table B.9-1: SRS configuration + +| CSI-RS IEs | Possible values | Config 1 | +|------------|-----------------|----------| +|------------|-----------------|----------| + +| | | | +|------------------------|-----------------------------------------------------------------------------------------------------------------|-------------| +| freqDomainPosition | INTEGER (0..67) | 10 | +| usage | ENUMERATED {beamManagement, codebook, nonCodebook, antennaSwitching} | nonCodebook | +| startPosition | INTEGER (0..5) | 0 | +| nrofSymbols | ENUMERATED {n1, n2, n4} | n2 | +| nrofSRS-Ports | ENUMERATED {port1, ports2, ports4} | port1 | +| resourceType | aperiodic, semi-persistent, periodic | periodic | +| periodicityAndOffset-p | CHOICE {sl1, sl2, sl4, sl5, sl8, sl10, sl16, sl20, sl32, sl40, sl64, sl80, sl160, sl320, sl640, sl1280, sl2560} | sl10 | + +## B.10 IMS Settings + +VoNR call depends on the following parameters: + +- IMS APN: The APN used for IMS services. +- P-CSCF (Proxy Call Session Control Function) Address: The IP address or FQDN of the P-CSCF. +- S-CSCF (Serving Call Session Control Function) Address: The IP address or FQDN of the S-CSCF. +- VoNR Enabled: Flag to enable or disable VoNR services. +- GBR (Guaranteed Bit Rate): Bit rate guarantees for specific services. +- SIP Timers: Various timers (e.g., T1, T2, T4) for SIP transactions. +- AMR-WB Codec: Configuration for Adaptive Multi-Rate Wideband codec. +- SIP Proxy Address: The address of the SIP proxy server. +- SIP Registration Expiry: The duration for SIP registration validity. +- SIP Outbound Proxy: Address of the outbound proxy for SIP signalling. + +# Annex C (informative) + +## C.1 Initial Access Flow + +Figure C.1-1: Initial Access Flow + +![Sequence diagram showing the Initial Access Flow between UE, O-DU (PHY, MAC/SCH, RLC, F1AP), O-CU (F1AP, PDCP, SDAP, RRC), and AMF.](8d60a369f0702dc884ee5b01ff854d45_img.jpg) + +The diagram illustrates the Initial Access Flow between the UE, O-DU (comprising PHY, MAC/SCH, RLC, F1AP), O-CU (comprising F1AP, PDCP, SDAP, RRC), and AMF. The flow is initiated with cell configuration and broadcasting MIB SIBs. + +**Sequence of events:** + +1. Preamble send (UE to PHY) +2. Preamble report (PHY to MAC/SCH via FAPI) +3. RAR (MAC/SCH to PHY) +4. RAR (PHY to UE) +5. RRCSetupRequest (UE to PHY) +6. UL data notification (PHY to MAC/SCH) +7. Data transfer (UL) (MAC/SCH to RLC) +8. INITIAL UL RRC MESSAGE (RLC to F1AP) +9. SRB Config (F1AP to RLC) +10. RB Config (RLC to MAC/SCH) +11. INITIAL UL RRC MESSAGE TRANSFER (F1AP of O-DU to F1AP of O-CU) +12. INITIAL UL RRC MESSAGE TRANSFER (F1AP of O-CU to PDCP) +13. PDCP entity establishment (PDCP to RRC) +14. DL RRC MESSAGE TRANSFER (RRC to PDCP) +15. DL RRC MESSAGE TRANSFER (PDCP to F1AP of O-CU) +16. DL data (F1AP of O-DU to RLC) +17. Buffer status reporting, Schedule result reporting, Data transfer (DL) (RLC to MAC/SCH) +18. Data transfer (DL) (MAC/SCH to PHY) +19. RRCSetup (PHY to UE) +20. RRCSetupComplete (UE to PHY) +21. UL data notification (PHY to MAC/SCH) +22. Data transfer (UL) (MAC/SCH to RLC) +23. UL RRC MESSAGE TRANSFER (RLC to F1AP of O-DU) +24. UL RRC MESSAGE TRANSFER (F1AP of O-DU to F1AP of O-CU) +25. UL RRC MESSAGE TRANSFER (F1AP of O-CU to PDCP) +26. SRB Data Indication (PDCP to RRC) +27. INITIAL UE MESSAGE (RRC to AMF) +28. INITIAL CONTEXT SETUP REQUEST (AMF to RRC) +29. SRB Data Request (RRC to PDCP) +30. UE CONTEXT SETUP REQUEST (PDCP to F1AP of O-CU) +31. UE CONTEXT SETUP REQUEST (F1AP of O-CU to F1AP of O-DU) +32. DL data (F1AP of O-DU to RLC) +33. Buffer status reporting, Schedule result reporting, Data transfer (DL) (RLC to MAC/SCH) +34. Data transfer (DL) (MAC/SCH to PHY) +35. SecurityModeCommand (PHY to UE) +36. SecurityModeComplete (UE to PHY) +- UL data notification (PHY to MAC/SCH) +- Data transfer (UL) (MAC/SCH to RLC) +- UL RRC MESSAGE TRANSFER (RLC to F1AP of O-DU) +- UL RRC MESSAGE TRANSFER (F1AP of O-DU to F1AP of O-CU) +- RB Config (F1AP of O-DU to RLC) +- RB Config (RLC to MAC/SCH) +- UE CONTEXT SETUP RESPONSE (F1AP of O-DU to F1AP of O-CU) +- UE CONTEXT SETUP RESPONSE (F1AP of O-CU to PDCP) +38. PDCP entity establishment (PDCP to RRC) +39. QoS flow to DRB mapping (RRC to SDAP) +- UL RRC MESSAGE TRANSFER (PDCP to F1AP of O-CU) +- DL RRC MESSAGE TRANSFER (F1AP of O-CU to F1AP of O-DU) +- DL data (F1AP of O-DU to RLC) +- Buffer status reporting, Schedule result reporting, Data transfer (DL) (RLC to MAC/SCH) +- Data transfer (DL) (MAC/SCH to PHY) +- RRCReconfiguration (PHY to UE) +- RRCReconfigurationComplete (UE to PHY) +- UL data notification (PHY to MAC/SCH) +- Data transfer (UL) (MAC/SCH to RLC) +- UL RRC MESSAGE TRANSFER (RLC to F1AP of O-DU) +- UL RRC MESSAGE TRANSFER (F1AP of O-DU to F1AP of O-CU) +- UL RRC MESSAGE TRANSFER (F1AP of O-CU to PDCP) +- PDCP entity establishment (PDCP to RRC) +29. SRB Data Request (RRC to PDCP) +- SRB Data Indication (PDCP to RRC) +- INITIAL CONTEXT SETUP RESPONSE (RRC to AMF) + +Sequence diagram showing the Initial Access Flow between UE, O-DU (PHY, MAC/SCH, RLC, F1AP), O-CU (F1AP, PDCP, SDAP, RRC), and AMF. + +## Revision History + +| Date | Revision | Author | Description | +|------------|----------|------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2020.11.09 | 01.00.00 | Venkata Nagesh (Radisys)<br>Rajat Kumar Pati (Radisys)<br>Manish Kaushik (Radisys) | First release | +| 2021.07.07 | 02.00.00 | Venkata Nagesh (Radisys)<br>Manish Kaushik (Radisys)<br>Veeresh Neginhal (Radisys) | Added O1 and E2 test cases<br>(From ORAN.WG8.IOT.016 to<br>ORAN.WG8.IOT.026) | +| 2021.11.18 | 03.00.00 | Venkata Nagesh (Radisys)<br>Manish Kaushik (Radisys)<br>Veeresh Neginhal (Radisys) | Added O1 and Beam<br>Management testcases.<br>(From ORAN.WG8.IOT.027 to<br>ORAN.WG8.IOT.035)<br><br>Updated the document to use<br>LLS-C1 to LLS-C4 profiles for<br>Time Synchronization. | +| 2022.03.22 | 04.00.00 | Venkata Nagesh (Radisys)<br>Manish Kaushik (Radisys)<br>Veeresh Neginhal (Radisys) | RAN slicing feature<br>configuration/functionalities.<br>Inter O-DU Handover within<br>an O-CU.<br>O-DU Timing Synchronization<br><br>(From ORAN.WG8.IOT.036 to<br>ORAN.WG8.IOT.053) | +| 2022.07.27 | 05.00 | Manish Kaushik (Radisys)<br>Veeresh Neginhal (Radisys)<br>Uday Parida (Simnovus) | Beam failure detection and<br>recovery<br>SRS and CSI-RS feature<br>O1 and E2 interface –<br>collection and transfer of<br>statistics<br>O1 and E2 interface –<br>parameter reconfiguration<br><br>(From ORAN.WG8.IOT.054 to<br>ORAN.WG8.IOT.065) | +| 2022.11.09 | 06.00 | Manish Kaushik (Radisys)<br>Veeresh Neginhal (Radisys)<br>Uday Parida (Simnovus) | Updating the TCs to include<br>O1 and FH interface<br>procedures.<br>(From ORAN.WG8.IOT.001 to<br>ORAN.WG8.IOT.065) | +| 2023.03.12 | 07.00 | Manish Kaushik (Radisys)<br>Veeresh Neginhal (Radisys)<br>Uday Parida (Simnovus) | Added new TCs to verify<br>Cloudification, PTP sync loss<br>and security procedures.<br>(From ORAN.WG8.IOT.066 to<br>ORAN.WG8.IOT.074) | + +| | | | | +|------------|-------|----------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2023.06.29 | 08.00 | Manish Kaushik (Radisys)<br>Veeresh Neginhal (Radisys) | Updating the TCs to include O-CU cloudification aspects.<br>(From ORAN.WG8.IOT.066 to ORAN.WG8.IOT.068)<br><br>Added two new TCs to verify massive MIMO optimization.<br>(From ORAN.WG8.IOT.075 to ORAN.WG8.IOT.076) | +| 2023.11.06 | 09.00 | Veeresh Neginhal (Radisys)<br>Rahul Saxena (Radisys) | Updating the IOT specification to latest version of WG specifications. | +| 2024.03.20 | 10.00 | Veeresh Neginhal (Radisys)<br>Rahul Saxena (Radisys) | Added new TCs to verify Shared O-RU and M-Plane procedures.<br>(From ORAN.WG8.IOT.077 to ORAN.WG8.IOT.082)<br><br>Updating the TC to include C/U plane transport connectivity validation.<br>(ORAN.WG8.IOT.073)<br><br>Updating section referencing per latest version of AAD specification (O-RAN.WG8.AAD.0-R003-v12.00) | +| 2024.07.11 | 11.00 | Veeresh Neginhal (Radisys)<br>Rahul Saxena (Radisys) | Added new TCs to verify RoHC and RAN Slicing.<br>(From ORAN.WG8.IOT.083 to ORAN.WG8.IOT.087) | +| 2024.11.11 | 12.00 | Veeresh Neginhal (Radisys)<br>Rahul Saxena (Radisys)<br>Manish Malviya (Radisys) | Added new TCs to verify Network energy saving.<br>(From ORAN.WG8.IOT.088 to ORAN.WG8.IOT.089) | \ No newline at end of file diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0217c4f7707ef7a6346dc79b0f4997c4_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0217c4f7707ef7a6346dc79b0f4997c4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..beb54d3d994b7b8fa70b5abe29068cd4e5054b76 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0217c4f7707ef7a6346dc79b0f4997c4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:add3297394795191d54bc6cfa8d547d1d1302036f9e9ef4eacd6edf41e9d389f +size 75792 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/035861cb2ca07b40648c3db961127938_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/035861cb2ca07b40648c3db961127938_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ba9e05fc336b76337fd15ddbf516fd4fed57a7f7 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/035861cb2ca07b40648c3db961127938_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0f3020ed2e6831300ea9c9e6df1fce71cbec56bdf8bcdc281c1c2c593c91c98f +size 91493 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/03af190f48050894bf6205a818e8eac4_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/03af190f48050894bf6205a818e8eac4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..68e506d87d6cb15031d103eac2f5b11291e5516c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/03af190f48050894bf6205a818e8eac4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:279196ee61f77e926d98dc6bd09aac3580a423d2e57dca66d4bcf8f033d0a6e5 +size 50171 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/07ee376ad62709c90a4d80978b3c05de_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/07ee376ad62709c90a4d80978b3c05de_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6474193ffad9fbfff89971932201f920719a06b0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/07ee376ad62709c90a4d80978b3c05de_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0ef5fa7f6fa3ec72db72531a546babcdfcf0a2e9cb4e7c25228c30f590fdd119 +size 4521 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0a011f4e1a8e0409fea3f377151aae75_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0a011f4e1a8e0409fea3f377151aae75_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..219b245e3e05921d8d2a1993779cdae1b36086a5 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0a011f4e1a8e0409fea3f377151aae75_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2c8c248c0245e0676f95a5aa1280084ec6f8809f22eb38554c91710884aa3b97 +size 78197 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0a1c2829f6b337ee487b2962b3470cb2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0a1c2829f6b337ee487b2962b3470cb2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4b4cc1d965f6ef0e425e2656a033398df29f585e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0a1c2829f6b337ee487b2962b3470cb2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:736c5d3b88904aa9d34cf2ad6bd2253b1287fbdd2925a320ebf9e5be20344827 +size 44775 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0c1ccbcf7cd691adff95cd65b3996ff0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0c1ccbcf7cd691adff95cd65b3996ff0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8c806f69b624d43be4fe983f11a93168c261bab9 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/0c1ccbcf7cd691adff95cd65b3996ff0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab7c8b6cae1e7222411381243684ea45a4bd98b1695b3a7da2f5ef787081e237 +size 36074 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/100c8b2e5e489241b0a39f73a8896fd5_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/100c8b2e5e489241b0a39f73a8896fd5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c1e190c8c726f6de908caff6defa6f2a60623b75 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/100c8b2e5e489241b0a39f73a8896fd5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da4b8f6df08680530eb8eb29125e306de30878deacffefdc3e822a5b19e2e07b +size 4511 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/100f56efac29ab5756a69598750ab957_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/100f56efac29ab5756a69598750ab957_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2074044710cbc20c5c46e884e8af5b65f19e3557 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/100f56efac29ab5756a69598750ab957_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3f0d9e8963fec1cbb0433630e5d9eef21acd7dbac1ed301c032f7da114c92a87 +size 4645 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1028071871ebe5af8e56b53bb1825a36_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1028071871ebe5af8e56b53bb1825a36_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e6052e6187c043d3179cb15af86317c94901ed08 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1028071871ebe5af8e56b53bb1825a36_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6e22a6c40cbcfd6058895bdabe634a302a85b3268930b90669528a95f80cd6e2 +size 71472 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1206c204cf6657624fe364d384de0d70_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1206c204cf6657624fe364d384de0d70_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a1da36818e0c7830cc7549409f29a4ca59141dd7 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1206c204cf6657624fe364d384de0d70_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8c2a4455d1e8bc39300a0a58e5bf024dbaa34d0a5369b03dff6e2ff938c437e0 +size 29053 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/121bb09aeecf8c57c36706539fa4321c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/121bb09aeecf8c57c36706539fa4321c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6b3f5481acc845001f2f7506b2b852483d876da0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/121bb09aeecf8c57c36706539fa4321c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8a9c1b597c187221de8c9b9107e764c17e543ab0829b0436dd4a29f55abada31 +size 93072 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/14ea6df6e81de64fc6390f4cbc573571_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/14ea6df6e81de64fc6390f4cbc573571_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b51a32295ed9b64ebeee82ca85e0b0e368fae5b5 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/14ea6df6e81de64fc6390f4cbc573571_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e70fffabae2883eee08116b8bfd744cd32ecb1daf033dd789a48339133c31dcd +size 28289 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/188afe76017ed99c2e02a35394bb9aeb_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/188afe76017ed99c2e02a35394bb9aeb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..706597cb52422efa2c0aaba62f94323f0a414ded --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/188afe76017ed99c2e02a35394bb9aeb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da5729dceddf5b6fbd531d58b55ef76e75f00face5c8cf1f5f738ab700d65cd5 +size 4381 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1f72f4ce76ecfe3083ef5acabf2945a8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1f72f4ce76ecfe3083ef5acabf2945a8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0ce14ceba61099414712309863c6536cfa74816c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1f72f4ce76ecfe3083ef5acabf2945a8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f7c65a3a2ea2793015d3125efdc46fa62611b2df4a889ae2900d2d9c2376e0a7 +size 58781 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1f74b5a15416d9cdd60679ae4a53678f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1f74b5a15416d9cdd60679ae4a53678f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..51b441e526454df81af8542aa93f3063ca2030d1 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/1f74b5a15416d9cdd60679ae4a53678f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:958c7c61b3b8850130308ce2891438c73b199be125ba2a83bd7aa0a32b626d52 +size 86872 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/26a388e0b8920827b16524108fb9e5ff_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/26a388e0b8920827b16524108fb9e5ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..399648d325282563e37057477837b7ea6cd1ef6b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/26a388e0b8920827b16524108fb9e5ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:98bbe4ab56077f2daaf363c31b13c1eed25a93dfacf9b85a151e03eef99b0acb +size 52172 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/277b54f1fa9e314b1f8e14a1e5ef7714_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/277b54f1fa9e314b1f8e14a1e5ef7714_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..75b352ea49b971d9fd9510d363c196fb15b97ed4 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/277b54f1fa9e314b1f8e14a1e5ef7714_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a1aef869706b6fce2ad77ef2b0011178f53c6004bc8939763bd9c32ec7f4a7d0 +size 83964 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/289faf27d7c1a98f00c626ca89e26b33_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/289faf27d7c1a98f00c626ca89e26b33_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7e082a20d32794b31833d7a1927e1f36bac48e57 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/289faf27d7c1a98f00c626ca89e26b33_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4cb97a46ae76a3867426e20ba0df99f49d0f20c5f1511c765838c4cd27d6c776 +size 92548 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/2b51f0054f46ff5aeeadb11c8bca83f8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/2b51f0054f46ff5aeeadb11c8bca83f8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..59349db59bcb674e66a298564866ec540608ff07 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/2b51f0054f46ff5aeeadb11c8bca83f8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e14aafa2ba03161f4c69edecc37a3b12c83b490a000a39fbec0e8d0c7bf9ba54 +size 75566 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/2be76a848bb89bce5c7680358ed46405_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/2be76a848bb89bce5c7680358ed46405_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ba27475ecf0a4b2789614f5ca78398597f01624c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/2be76a848bb89bce5c7680358ed46405_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3058d5e495bff961cfced7098ef94dcc8b35b85946d549d96d8edbb53539546f +size 49645 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3194145ff4fb03bf0f9bbb7971116689_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3194145ff4fb03bf0f9bbb7971116689_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7d747f4a39751bb36df5c9d2b2322141858d6b14 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3194145ff4fb03bf0f9bbb7971116689_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0513503bc01a88a7328d08ba7cde61a8be6e7b852c5af4b9ffa0fa022313c880 +size 4522 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/32b2adeeb6875e9ed4d0495e5d07c2a4_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/32b2adeeb6875e9ed4d0495e5d07c2a4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..912aaafa48474a6ac0c6b2b17d9e1bc3fd99f3e0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/32b2adeeb6875e9ed4d0495e5d07c2a4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:240ed16e6565b77e58b58fdab834d752218c372faa7d79c5a6d0361540d6fa12 +size 163673 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/33e60d06890a8ee27cd3a6a8d91e9b53_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/33e60d06890a8ee27cd3a6a8d91e9b53_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e1c2537d953aedb0bbbc6a0f67a901488c63cecf --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/33e60d06890a8ee27cd3a6a8d91e9b53_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3355fb0471021ac66167207117fc638c31bc40682c4317094230025eeed4acf9 +size 67284 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3411da76aef221d23d9e0f4bc753b3d9_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3411da76aef221d23d9e0f4bc753b3d9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a15ca119d1f4019d29d589a3e0ab67f80f5abb4b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3411da76aef221d23d9e0f4bc753b3d9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f3286bdb8a11c58bfc01a4b32806b47e807dbc2fe17a9f15840e43188e8f7254 +size 33128 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3847fbb17a2cf56b2f3f602649461beb_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3847fbb17a2cf56b2f3f602649461beb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..61a82a59e7ec2133c31d6223cd6a1f74c469a76a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3847fbb17a2cf56b2f3f602649461beb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce6f2e3cee8285fb050735923c78a68314c3cbf2e0738f1be0e9a241b5ed475b +size 4457 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/38b42e1430093f10b1ba032f9271f65f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/38b42e1430093f10b1ba032f9271f65f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9d133ec96a896cf94ac9527ee6e2c316e5b77fa6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/38b42e1430093f10b1ba032f9271f65f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:665ea8a42b40889f66682362d00273351f0d056fbed5551914564b950765fde5 +size 34360 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3ac6adae71c891d0620c94af44d97e41_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3ac6adae71c891d0620c94af44d97e41_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fe22808bd9f882a4f573a1ca245f82901e8811a3 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/3ac6adae71c891d0620c94af44d97e41_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d2baf69a28ecaf1e4b8ce87ba7fe9abcd2e2f327445fae2eda26d127fecffa7d +size 59160 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/45cc89f04be5ccf817e40eefed6cdeb3_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/45cc89f04be5ccf817e40eefed6cdeb3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8b58a2bd4a8d3a0d221f2253bd4d58a09f9dd0ef --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/45cc89f04be5ccf817e40eefed6cdeb3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:856d06880e87a75b70720c84f9fb4e898061eac7854ec3c2b70ced75a3b98721 +size 66103 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/461876e8bc7518eae59725e61a696bca_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/461876e8bc7518eae59725e61a696bca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..52a77c4f081413788a68425972f32feacfd64d2b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/461876e8bc7518eae59725e61a696bca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c3053768db3549fedb97c54b149bdba0050327b4556ada98bd59f3c8b36ab0f7 +size 69171 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/49c17b31789f6c3ff88eb981b1499ae0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/49c17b31789f6c3ff88eb981b1499ae0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8609b3e1e1139bb740175c3289c6ae858a19cffe --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/49c17b31789f6c3ff88eb981b1499ae0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e1bf44c4ce89b07310b7d4011011a949b3f1e0617c836471f03c0142facf2b4d +size 31557 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/4a7c448fa7d1201fff49f20089531bb2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/4a7c448fa7d1201fff49f20089531bb2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4466c754c586bd32a0bb370e89d8fd89aadd986b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/4a7c448fa7d1201fff49f20089531bb2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:493927dcd6b0424c20aa04cd1f2979eda12fd3a94ab52e1d61d8a00dc0fa6f34 +size 4683 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/4b178cc7ef16ba9e6ba23d15518947c2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/4b178cc7ef16ba9e6ba23d15518947c2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..404cdb148ca5417e555e48d0b10524b013bfe521 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/4b178cc7ef16ba9e6ba23d15518947c2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ca37322bca48de8e4f5b542c0c0dca1452e5cf8173fa0358d2706da3a83bc0f0 +size 51206 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/50e2be491896a20a2a0d457d4e7bc868_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/50e2be491896a20a2a0d457d4e7bc868_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2b118e2da9d8d78a0e9da5814cd8a173f8d2ade4 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/50e2be491896a20a2a0d457d4e7bc868_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:49c240f9b5bf39723e6f996fc832143022678ac57660884ad34948407e357471 +size 4579 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/54f55381ad446d116fd873025ff2e29f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/54f55381ad446d116fd873025ff2e29f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cc5a1bed3860344dd458a2ef7ce10a5ba167dfff --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/54f55381ad446d116fd873025ff2e29f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f1117c9b8bc70a5dcef4658bf662c78589360ce71d65260dd83686150d667c9b +size 39059 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/5ed10292556817208270271f388f5aa8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/5ed10292556817208270271f388f5aa8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f941761e7279a321a2406f5495ffa5a0966e3b24 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/5ed10292556817208270271f388f5aa8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:33f18ebb37e7186946a4caa60744654cbab884a233e779360c379eec311e37f3 +size 131779 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/608e4948278875b243d666c8a7c9be8b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/608e4948278875b243d666c8a7c9be8b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f26ad056439fe3f8068879bd4b24e73e5b342041 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/608e4948278875b243d666c8a7c9be8b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce49d177bbbb53271c87d37a916530f288b8a456622e78b5b3103d0e95cc2d9c +size 69893 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/667f04a4e986dccb364f5486178cffab_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/667f04a4e986dccb364f5486178cffab_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dc1c28e5c4061c3ca211a56c93930231ef539ca1 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/667f04a4e986dccb364f5486178cffab_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:688aa44811a801bcd7f72932ac7aebc9d715a01b2db7dac54afece65c65d146b +size 66115 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/66f1a6b4fae2c2334ad905222fb29d99_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/66f1a6b4fae2c2334ad905222fb29d99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e4d072ecae8ed913a1daa4690bcc010de8fbfbf2 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/66f1a6b4fae2c2334ad905222fb29d99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e1748487569077578798fba4986cd63c1a3dcefb18101f3a02ba6ed65c1d9512 +size 52729 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/68a7ca8ee3052c1504604df432afe74e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/68a7ca8ee3052c1504604df432afe74e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8ac3b5b77a16569ae9c85f7278c05374e0573ffd --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/68a7ca8ee3052c1504604df432afe74e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:62dbe58d6c3903f541b6ed9f201af732a68338e805865ddfb73d71317f307831 +size 44262 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/6ae6bd6c0bf297ee9a156fad13083852_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/6ae6bd6c0bf297ee9a156fad13083852_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ce4b6a68cac19a030832a06567979e6d9df7bf50 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/6ae6bd6c0bf297ee9a156fad13083852_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cee42b7d43332f3f5b69f0d5b7fda3d1896c030707cc681f2afcdfad34b75ac2 +size 55970 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/6c6f90b7a34ea606bed25104f4fee339_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/6c6f90b7a34ea606bed25104f4fee339_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2f8d6985a44d4b0a6db875427eee935aba79889 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/6c6f90b7a34ea606bed25104f4fee339_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d655cc3bd3138477c8d193054273adf0a386e2b3bc62e9b60710a3e368d7f398 +size 121922 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/70afaf934947a8c7529c71b1406a6bba_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/70afaf934947a8c7529c71b1406a6bba_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..26915adfe1a2bd90abe8f8102bf0bb7410a21c4d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/70afaf934947a8c7529c71b1406a6bba_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4055bf5c888b7bf095322ed2d34fc8ccdf49e0826552ba5dcd7f2601b80fa2e4 +size 60980 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/75e9903d54dff18c5eccec64e77fc196_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/75e9903d54dff18c5eccec64e77fc196_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0a1326f1aff8686f04ba2d3f4538af3ebba92736 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/75e9903d54dff18c5eccec64e77fc196_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ff913446946f6c44c3d109621d37593f8a972b5afd622ed4298a4d3221bd0fa5 +size 60773 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/7e019d67223613e77828e1aa2c8bd053_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/7e019d67223613e77828e1aa2c8bd053_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7fba63695a4c0fc31c4f6dd88056dc952c0f99fb --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/7e019d67223613e77828e1aa2c8bd053_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:930d84657cfce14bd3356ba0509e0c4b6fac4cc2fad842e91b0dec56358a52be +size 4631 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/7e9862139b349cf411c34d889c078775_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/7e9862139b349cf411c34d889c078775_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a716f75cd895754f1813c1d5e41f3341c18c68e9 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/7e9862139b349cf411c34d889c078775_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:af60b6395de2f9e0618b8ce65efcbfddadeaadb53605be1b48410655c1585796 +size 57492 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/7fb3c0ff0eabc7948da26f9bc02b6158_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/7fb3c0ff0eabc7948da26f9bc02b6158_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de3a8c94ab4ccc82a6b1c566477004c2988a8962 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/7fb3c0ff0eabc7948da26f9bc02b6158_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:962e59fa5cf98b28311c862c25faa9f49095150c55a1295eb1f7da1ade748a0b +size 4478 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8153914d64fece43dcd3ddc6809f417b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8153914d64fece43dcd3ddc6809f417b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..99345a4976b403c4ef06fa80985cea93b23fe80c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8153914d64fece43dcd3ddc6809f417b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab4d33b125019f4cc24ea9e4fb1f564945813f7216b30e73908d5b9b96e3e6b5 +size 99096 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8677a5e51448a3599cce1cf25534c903_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8677a5e51448a3599cce1cf25534c903_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3f04224d1332839d14f3264460f91f764062338b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8677a5e51448a3599cce1cf25534c903_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:86b2b5123c964aec4d2b2826e55e29f82afd6b446db109486dd1612cf9e97ab1 +size 85256 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/874133836aed96cd6fe46becfcc6d0b2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/874133836aed96cd6fe46becfcc6d0b2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5a42b83d8407b3e4098481086ee20de58907184f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/874133836aed96cd6fe46becfcc6d0b2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5999b94e665eb6f96266e921f120c03eaaca5a47de3675df97e13d191caca642 +size 60759 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/88d4709e433a44856abc7a8931ee013e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/88d4709e433a44856abc7a8931ee013e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2235b983515fc4aff044a5798b6afce04571b384 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/88d4709e433a44856abc7a8931ee013e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:95188b3096374ee81365c71fe44d5f0e5282e563c5ef3283113d91ea7850f3cd +size 61997 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8a8c881227c68d1523bf0ad40b06b429_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8a8c881227c68d1523bf0ad40b06b429_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..79e2fe7a16503ebb0fc8a3fae69e1cfe4208533a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8a8c881227c68d1523bf0ad40b06b429_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:742b1935a5ba440432a2c3c7c79b6817ae429181acf59879791ea6c45c9ba9b5 +size 85432 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8b0c684809ca30be0934fd70d97e6ccc_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8b0c684809ca30be0934fd70d97e6ccc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cec0f042432082f9609d096d2ae79143ce97e8af --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8b0c684809ca30be0934fd70d97e6ccc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e4c497e5abcc8e053ac9b34ed0af472cb386f44cfd5ea9faf4cad6c44a733041 +size 170552 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8b8dd66c264585aba05acf012e88eee4_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8b8dd66c264585aba05acf012e88eee4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cf43999d418ea6ec92be063d3e9b98f8e88c8340 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/8b8dd66c264585aba05acf012e88eee4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:79459efa4e677076accc283f7f690abcfc42a5937bb068778903f098b21940cc +size 27929 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/908c1e5bc4d8fd2323b9c639234682cc_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/908c1e5bc4d8fd2323b9c639234682cc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..18d0af39c03dfc69087e26013cf1372f9a35b3d6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/908c1e5bc4d8fd2323b9c639234682cc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1f660e4a890e190fc9c5d93da7d7655fce90e1263e0508164de0e6ef40bfae9f +size 65759 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/957eadcf27657f3e9a6ec7322967b8ab_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/957eadcf27657f3e9a6ec7322967b8ab_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..88563e944e856e4ba015d9000982c7afe82110fb --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/957eadcf27657f3e9a6ec7322967b8ab_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:358173083f7ee9aa464bfd6877e1a96e3d1d3cd545cca38cbdc8afa7f460bbf9 +size 52759 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/96e878324c81c75e6536e179097ff43b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/96e878324c81c75e6536e179097ff43b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4a8b2572a6c51b21829b1af36880c03b9865b51c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/96e878324c81c75e6536e179097ff43b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e25289a9a707299072ecf3d45aa4ca9fcf7889c4c0b315f39adc106debefe4e9 +size 69670 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/9746772a9b6b17945a7fb5ac246814fb_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/9746772a9b6b17945a7fb5ac246814fb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dbf9987252677a44a7bc2f2a8458971ea120b0fa --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/9746772a9b6b17945a7fb5ac246814fb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:43edb5ea41de36bd66a582bf1968692e7458074f66efface2865e172de8edd14 +size 26419 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/9946e0efb16aa5076a38f9f1a4611c51_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/9946e0efb16aa5076a38f9f1a4611c51_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3cfcb02aeea255c9f77a4a9c65a614ed72ffa831 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/9946e0efb16aa5076a38f9f1a4611c51_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a781a00f63748f6a1c91f418574fce8a99228d95ca90258f1c8e6112a4c6d99a +size 70087 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/99be9500d936730cac909cdccf03deeb_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/99be9500d936730cac909cdccf03deeb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ad1bfcbfaaeb94e23637af07735c0e187948a71f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/99be9500d936730cac909cdccf03deeb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d5bff8f723fa2ded0f5cd7201c1deeed1d6b4494d6cbfacf12c48f217e88cf52 +size 4584 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/9c5e1cf6a447cf6840f08c864b6de497_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/9c5e1cf6a447cf6840f08c864b6de497_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bcacf3bbecf66749e22cd00f6128792f57dc2c89 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/9c5e1cf6a447cf6840f08c864b6de497_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:49e811a8d40cb4c834397cf3c80835d2ca99e3d29ce343fa3ffabc5502a309ac +size 53033 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a3d4d29cf7e7bec526fd7b98c93f8fde_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a3d4d29cf7e7bec526fd7b98c93f8fde_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..614cc3ae4fd2a2fd6803c6c27fdbc91ef4ad400e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a3d4d29cf7e7bec526fd7b98c93f8fde_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:887eac705f4ec25c156625cb9c44f97b080ea97586a14fe5e261bb650edd1104 +size 62775 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a543c9cfb2028f65a96ec76f3ea4ce02_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a543c9cfb2028f65a96ec76f3ea4ce02_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..39bc5e78552cd2cfd05722691f0bdcc60e490ce1 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a543c9cfb2028f65a96ec76f3ea4ce02_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e11242e8eb8826c187d4733ab8405ef554f070eb4eba94dc108b9fa771df5a5b +size 82886 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a6fee58ea6308479c60f45046f4d731f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a6fee58ea6308479c60f45046f4d731f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f3ad16e509eaf6f97b5842679c625ff68dcb9822 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a6fee58ea6308479c60f45046f4d731f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:794558a0e156e4f2f307ef135ce9a4f382e104c6c3dd7ddea69ad6abd0eb1e1b +size 85074 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a828c396b6d8703449ba4b53cbba3ebe_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a828c396b6d8703449ba4b53cbba3ebe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbebcb8ba77a762f0f64dc0efa5f2d0481b9957b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/a828c396b6d8703449ba4b53cbba3ebe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a7f0198d215b3d694db706c87d35d46cc02533ba8fba60ab4f528170351a9248 +size 55506 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/aa9efa3f68b336d9038be0697d28a549_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/aa9efa3f68b336d9038be0697d28a549_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e5b604f7ee6ac8c41110634247ed52f4fed84eae --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/aa9efa3f68b336d9038be0697d28a549_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70106ea9a185bea484767bb9483a966720a3b2177f93a82978509807184cd46f +size 43117 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/ab3072b64998ed96600a43311ecd2f44_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/ab3072b64998ed96600a43311ecd2f44_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dcbc9a677a09e7a90e9af34aae005f2a9d461875 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/ab3072b64998ed96600a43311ecd2f44_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:66e82efc64e9feb5fa0685168dc058fe60603f25fe22a08cb68f1aeea3708e4e +size 4545 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/b2282fc9667b4b7b01e1481310da8d6e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/b2282fc9667b4b7b01e1481310da8d6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ead2376ee0bd448a573893062182c3fdb40c17c8 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/b2282fc9667b4b7b01e1481310da8d6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ed814a47ff4457a1cf7fb60271c43779fcf86e9153013cabff667fb1cd7eb138 +size 157739 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/b26d38f02766476dee9d8a9ac94fd2f1_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/b26d38f02766476dee9d8a9ac94fd2f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d5026b66c4ece77285ed3771749a8a96b14ac8a8 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/b26d38f02766476dee9d8a9ac94fd2f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e492bb86d264ddc6629ed60f278ade21717f67e4911365a7a2434d3bf639d967 +size 127054 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/b52f7154ddcfdc97047a11680f1bc7a7_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/b52f7154ddcfdc97047a11680f1bc7a7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c178e92ebd8d1dea9d5de271d1109ca59fae769d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/b52f7154ddcfdc97047a11680f1bc7a7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6e1e01868a9257020dfd12ee27452ee81e746aaa7cd0eafe92eb9e247648535d +size 69387 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/ba8b318257c23bd6627997857fa0e82c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/ba8b318257c23bd6627997857fa0e82c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ca9df32109aa2005ade96f8a12765eac710d42f2 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/ba8b318257c23bd6627997857fa0e82c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2c4506e189103db562f155fd84fd78f6346660e280ec8c5a12aa59efc7035ef2 +size 80668 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/baab508bc3106e5771a74252963c9a4b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/baab508bc3106e5771a74252963c9a4b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e435dac9705f72fe10cbe1c81dd195455e7a393 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/baab508bc3106e5771a74252963c9a4b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:55790efde284a37812ce01bf28a4d2e3866c1437944b4317b8422701eb1209ec +size 89069 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/babf0d17d1b0140d9e86ea5a422acbac_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/babf0d17d1b0140d9e86ea5a422acbac_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..414a3837b26f1ad6059f430cde62d9b6e7599feb --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/babf0d17d1b0140d9e86ea5a422acbac_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:625af2381ad8227a4258ef593f11525ef56709c2716af39641b23ebf89dc4157 +size 4659 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/bad90f267214d5dea37739e8b1131718_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/bad90f267214d5dea37739e8b1131718_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f1aa24fb8b9ee25fb8582a62528b5a27ac49a3b6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/bad90f267214d5dea37739e8b1131718_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce32ef1c7fa4d2a1912014a107cc8ea307a15fb8dfd71743696b7ec466c79f42 +size 46386 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/bc05c54a82610eee722814b2f4c00839_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/bc05c54a82610eee722814b2f4c00839_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..06531ba36ce798c92dba7e66e01ced3bb430f3fb --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/bc05c54a82610eee722814b2f4c00839_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a4f80484fa28a984e9596cb2b30197ab732bc2660f103355cd6a187f68c36c96 +size 51743 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/bf6d824dae7832b6e3b17f3d53b31277_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/bf6d824dae7832b6e3b17f3d53b31277_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7b6fde419449122abcbe112d03de28fb0df97aa0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/bf6d824dae7832b6e3b17f3d53b31277_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8702b7775113040313563eb318dff3208540c34430aa8cfdd68b00a1efa5188a +size 67193 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c08e830594b0e47ef5c7c998f34a5d81_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c08e830594b0e47ef5c7c998f34a5d81_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..45a943db875fa077a96be8bc479ce95d8cbe42ee --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c08e830594b0e47ef5c7c998f34a5d81_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:692c198d42381371a21dafe3e344d0772ff49f2802c4fb6d666a15d1bf7d7e87 +size 25286 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c1888483d75b57066b8a079cb636f8dc_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c1888483d75b57066b8a079cb636f8dc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7a851fa5a8b080638dacad5c4139b76e4542f909 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c1888483d75b57066b8a079cb636f8dc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:87138101ad7582fc58a7d88ac545b1f5c9f38b82424a891a069a101055aecb43 +size 4540 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c3a245228804f3795b39dd18e38d7c4f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c3a245228804f3795b39dd18e38d7c4f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0536d45f0b1219fc768d2caa9bf12ef9a39c1cea --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c3a245228804f3795b39dd18e38d7c4f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bce32d07837b627816fd96436e07e40d2625a0befa82b5f4b8ceff0149379441 +size 27293 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c59c455aab57378a042d1e4ee73f0819_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c59c455aab57378a042d1e4ee73f0819_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..de1ab54cb7bffdf05c803eeb977888ed89a1a5ae --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c59c455aab57378a042d1e4ee73f0819_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9b99b4f119bc892983610dfde3876b19dd7600900f0f09e6a34baedaf7fb45b8 +size 4528 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c734e36ca7a5cc79a3668f3c8d6a6eef_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c734e36ca7a5cc79a3668f3c8d6a6eef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9587ab92925e8e3aff356adfe26c157bce17329c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c734e36ca7a5cc79a3668f3c8d6a6eef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5c8f141775e526e3852f7bee3207805f8febd26fe6171cf345a98b354a8a475e +size 4533 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c7eda84e1e1dec7bb5806ee719e2bdf8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c7eda84e1e1dec7bb5806ee719e2bdf8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3133a82c4c2350406d274b074a1979d3bf33171c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/c7eda84e1e1dec7bb5806ee719e2bdf8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:14a6a1eb7666943e4737973f10d5161fb4a7b9f31fdbd0729c824a539aa405d7 +size 4525 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cacee38349cd2eef26df1a5b135b6b1c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cacee38349cd2eef26df1a5b135b6b1c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f2a6299c739100329bf91b5e57ecbf3b26fba4d6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cacee38349cd2eef26df1a5b135b6b1c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:188c7a1fc8a279be8ba238f922288fce8f774b3a838e77b1b34d96d846e5ee71 +size 87080 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3d49e4c72efd9fae624a69b39088960f98b2cfdd --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cb6d19b19ec35219e75de55cbe4e957f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:32c045338d418c7eda3216d6a4a04c684fc7b28821698c0061eff9157664fbad +size 4527 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cc3b132d5e82e6f10c355d04ff55855e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cc3b132d5e82e6f10c355d04ff55855e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b92dbdb0792bf57b63e627baeab9fc55088386cd --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cc3b132d5e82e6f10c355d04ff55855e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4dd08d79b7ea4a4085f455d18506c0d2fb82c7f5cf589ec316d219d4177bd5f4 +size 4480 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cd062c4631827801b39e776b6ff61f6e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cd062c4631827801b39e776b6ff61f6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2c6e2176b162c5b967f39836493f37e5029d4ad0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cd062c4631827801b39e776b6ff61f6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:05a012e8b7a53a42c5fc74cc5e2b575ab4e0fedb6e09522f684a1e95cd3c1420 +size 41583 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cfbf0a48b31290a7278df08c94dae0f9_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cfbf0a48b31290a7278df08c94dae0f9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db9e9cc98f36ef65baf56b0eee5a3c81f3212e19 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/cfbf0a48b31290a7278df08c94dae0f9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e94ef11340996f72b683ac911bd718aff7cd1aada3539bc94f38f37107f6f2cd +size 69808 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/d23fddf7083fca3a20102acbc95b062e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/d23fddf7083fca3a20102acbc95b062e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c7ef8d37ab777418b366ab90e0ae8c44e32a5507 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/d23fddf7083fca3a20102acbc95b062e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fc1dc3155ad0c893fa8cad4a7eb056ca0c47701ce283b20b095061dda18ef4aa +size 59404 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/d86a32083b8f57907ba951350486dd3d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/d86a32083b8f57907ba951350486dd3d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3de7db62fdd5db8e375f7ad432436e3cf7e42e76 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/d86a32083b8f57907ba951350486dd3d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3fd0fde42bb859e08319d569b368e61c9cbce74c797fd48d313ab4cace81865d +size 50053 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/df9278566c2807beaff1feb638061500_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/df9278566c2807beaff1feb638061500_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b9f54f9292f2420f3ff6266f1be50c42919e90f7 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/df9278566c2807beaff1feb638061500_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:548e422574b1c09e89249cc307028d01c0b777e939541ae2ec0569569b564e2e +size 50443 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e0cabcfd411420055df5812af5433d04_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e0cabcfd411420055df5812af5433d04_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ed210ff5a5810748efb5e86163f833c4ca4e103b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e0cabcfd411420055df5812af5433d04_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:eb6d29a86e869606ea11289bb27ec95ea21e79806f926fdb55112de3f14db61a +size 127100 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e57b87433db9ce0e8faed8cbb9f8a810_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e57b87433db9ce0e8faed8cbb9f8a810_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c0884cc42d89779144de3ef4b824fcac418649b2 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e57b87433db9ce0e8faed8cbb9f8a810_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b7d477d94c8a12ff45cae97e7780f43c3312848a7da617fa2df6a9c204ea8784 +size 67674 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e810c4a896fb20a4685086c65463de8a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e810c4a896fb20a4685086c65463de8a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..50bc213da7cd96eba7954e67d6663b2fcab679fc --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e810c4a896fb20a4685086c65463de8a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fa5581027da149fd3264a0f69180812032871ac8f636785801bddc7c971e3013 +size 61124 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e918cb208eab85fadbeffa50c6523f33_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e918cb208eab85fadbeffa50c6523f33_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ef4dd092195d33ffecb21d03ea5f9a85c428c787 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e918cb208eab85fadbeffa50c6523f33_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8aeb4992a92e55d1eb73ca35ffba1fc673a41abaaf2beceec725c148060b6d7a +size 17746 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e96ae57f35e74c51f2f84c1fd18c1d52_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e96ae57f35e74c51f2f84c1fd18c1d52_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..79f23c286812eb91c86cf6c0857e000014534226 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/e96ae57f35e74c51f2f84c1fd18c1d52_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e3a3afeaa23758617daf6d7a6fda6d94e5258899de338260471814fd20a7d028 +size 72977 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/ebeb4e2772924cd0111d20d20d8533d0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/ebeb4e2772924cd0111d20d20d8533d0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..071902c301f0c65874570301d8d85db89e56fd52 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/ebeb4e2772924cd0111d20d20d8533d0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8dfa45944e02869d8be93f9b9e42992336aec4553c22d15ea3a78d0becce4c8c +size 59107 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/eed60b0b69f5f97d5c6b960d2e2d42a3_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/eed60b0b69f5f97d5c6b960d2e2d42a3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aef874638ca7e538aa0b7d4020b611e2f2f6a102 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/eed60b0b69f5f97d5c6b960d2e2d42a3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5743fdabba7c613698bb2fb664647ccce4a81cb2aa2e8cd4a76052ef9f5a56a1 +size 4510 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f0204576e1f1176711ce4c038ef8c631_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f0204576e1f1176711ce4c038ef8c631_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e385143b0fe5e1db2ed80e67e1eef5fc94bc091 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f0204576e1f1176711ce4c038ef8c631_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5a5a1e8215757b824319c7d9891544f94aebe3a5639a17d1da8836a829807653 +size 67961 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f171186b26ba5f257c55d5cff5e2fa16_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f171186b26ba5f257c55d5cff5e2fa16_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e77ad46cb51ebd1b398c035ce47d227f9ee7c110 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f171186b26ba5f257c55d5cff5e2fa16_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:56c546a03f645b2ac13026cf04de0de78df048ef079998a956cdc8dae269b48e +size 57811 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f30536010ed0ac2352191fe1c3e53be8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f30536010ed0ac2352191fe1c3e53be8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..608fb2c1f0f203fba7b19767562f18e596a206f8 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f30536010ed0ac2352191fe1c3e53be8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:69a6b48f758e9e0d1150a6d0363630a77fe09d6033b2ea2a53f8dc7adcc058e8 +size 4453 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f34023f99a914ab9322c026537548199_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f34023f99a914ab9322c026537548199_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8c55e622b9fbd10ac666820bd88a30dc4d303907 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f34023f99a914ab9322c026537548199_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3b518505cf3ca31bed644402c3ce1d0c53cf2c3f84f5073a65ea163c63b1c679 +size 83239 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f5474745e5c176ac0be4a6154e1fc22d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f5474745e5c176ac0be4a6154e1fc22d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..74082f49659d4efc7e42fd85223b1012e88a6120 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/f5474745e5c176ac0be4a6154e1fc22d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e21ad716504363eada8a6fe73fcc933a2ff3f0fbe2d8710344da29e166e09a0a +size 20453 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/fae7b157dd8a11380d3d2d396b5f23fe_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/fae7b157dd8a11380d3d2d396b5f23fe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..28b0a7ff79b9854cb539feacb750ad6f8f2655d3 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/fae7b157dd8a11380d3d2d396b5f23fe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a2d06bf4890a4739671488a3ed23a9118da5dad0818850127fb3aeefc9199f91 +size 67624 diff --git a/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/raw.md b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..a71ed009e29245b5c6ffa3d7b8b3ff09158ad776 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00/raw.md @@ -0,0 +1,3509 @@ + + +# **O-RAN Open X-haul Transport Working Group** + +## **Management interfaces for Transport Network Elements** --- + +Copyright © 2024 by O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V. Buschkauler Weg 27, 53347 Alfter, Germany + +--- + +# 1 Contents + +| | | | +|-------|------------------------------------------------------------------------|----| +| 1 | Contents..... | 2 | +| | Foreword..... | 4 | +| | Modal verbs terminology ..... | 4 | +| 1 | Scope ..... | 4 | +| 2 | References ..... | 6 | +| 2.1 | Normative references ..... | 6 | +| 2.2 | Informative references ..... | 7 | +| 3 | Definition of terms, symbols and abbreviations..... | 8 | +| 3.1 | Terms ..... | 8 | +| 3.2 | Symbols ..... | 8 | +| 3.3 | Abbreviations..... | 8 | +| 4 | Modelling Schema..... | 11 | +| 5 | Device Communication Protocols..... | 12 | +| 5.1 | Configuration Management ..... | 12 | +| 5.2 | Fault and Performance management ..... | 12 | +| 5.3 | Life cycle management..... | 12 | +| | Annex A (informative) ..... | 13 | +| 1 | Transport Technology dependent analysis ..... | 13 | +| 1.1 | Microwave transport ..... | 13 | +| 1.2 | Optical access ..... | 15 | +| 1.2.1 | TDM-PON ..... | 16 | +| 1.2.2 | Point-to-point interfaces ..... | 19 | +| 1.2.3 | WDM-PON ..... | 19 | +| 1.3 | Optical transport ..... | 19 | +| 1.3.1 | Fronthaul WDM systems ..... | 19 | +| 1.3.2 | Mid- and backhaul ROADM transport..... | 25 | +| 1.4 | IP/Ethernet transport ..... | 28 | +| 1.4.1 | Provisioning and managing a packet switched infrastructure ..... | 29 | +| 1.4.2 | Assessment methodology and analysis ..... | 30 | +| 1.4.3 | Conclusion ..... | 35 | +| 1.5 | Grand master clock ..... | 35 | +| | Annex B (informative): ..... | 36 | +| 1 | Network Slicing Use Case..... | 36 | +| 1.1 | 3GPP slicing model in application to network slicing in TN domain..... | 36 | +| 1.1.1 | History / modeling concepts..... | 36 | +| 1.1.2 | 5G Slicing ..... | 37 | +| 1.1.3 | Slicing in 3GPP Release 15..... | 38 | +| 1.1.4 | Slicing in 3GPP Release 16..... | 39 | +| 1.1.5 | Slicing in 3GPP Release 17..... | 43 | +| 1.2 | IETF Orchestrator and controller framework ..... | 45 | +| 1.3 | Uniform transport network model ..... | 47 | +| 1.3.1 | Multi-domain Support..... | 48 | +| 1.3.2 | Abstraction Layer..... | 50 | +| 1.3.3 | Uniform Device Information Model ..... | 51 | +| 1.3.4 | Conclusion ..... | 52 | + +![O-RAN ALLIANCE logo](99be9500d936730cac909cdccf03deeb_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN ALLIANCE' in blue and green. + +O-RAN ALLIANCE logo + +| | | +|-----------------------------------------------------------------------------------------------------------------------------------|-----| +| Annex C (informative) ..... | 53 | +| 1 Management and network models for correlation of Network Slicing in RAN and Core subsystems with Transport Network domain ..... | 53 | +| 1.1 IETF slice Framework design ..... | 55 | +| 1.2 Management and network models for Transport Network ..... | 64 | +| 1.2.1 Segmentation of the End-to-End Network Datapath ..... | 64 | +| 1.3 Management and network models of Network Slicing in ORAN subsystem ..... | 76 | +| Annex D (informative) ..... | 81 | +| Slicing use case revision history and progress control ..... | 81 | +| Annex E (informative) ..... | 83 | +| Use cases for the direct integration of transport into SMO / Non-RT RIC ..... | 83 | +| Use cases for the coordinated interface between transport management and SMO ..... | 91 | +| Annex F (informative) ..... | 95 | +| Mapping 3GPP NRM to IETF Network Slice IM/DM ..... | 95 | +| Annex G (informative) ..... | 101 | +| Revision history ..... | 101 | + +# --- Foreword + +This Technical Specification (TS) has been produced by ETSI Technical Committee {ETSI Technical Committee|ETSI Project|<other>} <long techbody> (<short techbody>). + +--- + +## Modal verbs terminology + +In the present document "**shall**", "**shall not**", "**should**", "**should not**", "**may**", "**need not**", "**will**", "**will not**", "**can**" and "**cannot**" are to be interpreted as described in clause 3.2 of the [ETSI Drafting Rules](#) (Verbal forms for the expression of provisions). + +"**must**" and "**must not**" are **NOT** allowed in ETSI deliverables except when used in direct citation. + +--- + +# 1 Scope + +This Technical Specification has been produced by the O-RAN Alliance. The document is intended to describe best practices for O-RAN transport Network Element (TNE) management interfaces. In this document, first, generic requirements are given in section 6 and 7 for these interfaces and then informative content in section 8 and 9 on device, network and service interfaces. + +Phase one of this document in early 2021 covered: + +- Microwave, +- TDM-PON, +- optical transport (fronthaul and mid-and backhaul) + +Phase 2 enhanced this document in July 2021 with the following topics: + +- IP/Ethernet for O-RAN slicing phase 1 +- Optical access for point-to-point interfaces and WDM-PON + +Phase 3 added the following topics in November of 2021: + +- Grandmaster clock for Synchronization, +- WDM fronthaul interface requirements for passive-passive and passive-active, +- Clarified security requirements, +- Network slicing use case. + +Phase 4 introduced the following content in March of 2022: + +- More details on network slicing use case + +Phase 5 enhanced the following content in November of 2022: + +- More details on network slicing use case + +Phase 6 added the following content in March 2023: + +- Annex A +- IETF uniform network model + +Phase 7 re-worked the document for ETSI compliance and added the following changes: + +- Slicing LS + +![O-RAN ALLIANCE logo](c7eda84e1e1dec7bb5806ee719e2bdf8_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN' in blue, with 'ALLIANCE' in smaller blue letters below it. + +O-RAN ALLIANCE logo + +Phase 8 added appendix E and F with the following content: + +- Use cases for direct integration of SMO / Non-RT RIC +- Mapping of IETF and 3GPP model proposal + +Phase 9 added content in appendix E: + +- Use cases for the coordinated interface between transport management and SMO + +The following items are not covered and may be addressed in phase 10: + +- Future phases of O-RAN slicing support. + +# 2 References + +## 2.1 Normative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +Referenced documents which are not found to be publicly available in the expected location might be found at <https://docbox.etsi.org/Reference>. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long-term validity. + +The following referenced documents are necessary for the application of the present document. + +- [1] IETF RFC 7950 – The YANG 1.1 Data Modelling language +- [2] IETF RFC 6241 - Network Configuration Protocol (NETCONF) +- [3] IETF RFC 6242 - Using the NETCONF Protocol over Secure Shell (SSH) +- [4] IETF RFC 7589 - Using the NETCONF Protocol over Transport Layer Security (TLS) with Mutual X.509 Authentication +- [5] O-RAN Security Focus Group specification document O-RAN.SFG.O-RAN-Security-Protocols-Specifications-v02.00.06.docx +- [6] Google Network Management Interface – gNMI - [github.com/openconfig/gnmi](https://github.com/openconfig/gnmi) +- [7] VNF Event Streaming – VES - <https://wiki.opnfv.org/display/ves/VES+Home> +- [8] ONF Core Information Model TR 512 +- [9] ONF Wireless Transport Model TR 532 +- [10] IETF RFC 8561 – Data Model for Microwave Radio Link +- [11] ITU-T specification G.988 +- [12] BBF WT-435: Netconf Requirements on OLT (including ZTP) +- [13] IEEE 1904.2 +- [14] ITU-T specification G.989.2 +- [15] ITU-T specification G.698.4 +- [16] ITU-T specification G.989.3 +- [17] ITU-T specification G.9806 +- [18] OpenConfig data models - <https://openconfig.net/projects/models/> +- [19] OpenROADM data models – <http://OpenROADM.org> +- [20] O-RAN Management Plane Specifications – <https://www.o-ran.org/specifications> +- [21] O-RAN WG9 Xhaul Packet Switched Architectures and solutions O-RAN.WG9.XPSAAS-v04 +- [22] <https://development.standards.ieee.org/myproject-web/public/view.html#pardetail/8494> +- [23] <https://github.com/YangModels/yang/blob/master/standard/ieee/draft/1588/ieee1588-ptp.yang> +- [24] IETF RFC8969 - A Framework for Automating Service and Network Management with YANG +- [25] IETF RFC8199 - YANG Module Classification +- [26] IETF RFC8309 - Service Models Explained +- [27] IETF RFC8466 - A YANG Data Model for Layer 2 Virtual Private Network (L2VPN) Service Delivery +- [28] IETF RFC8299 - YANG Data Model for L3VPN Service Delivery +- [29] 3GPP 28.531: “Management and orchestration; Provisioning” +- [30] 3GPP TS 28.533: “Management and orchestration; Architecture framework” + +![O-RAN ALLIANCE logo](188afe76017ed99c2e02a35394bb9aeb_img.jpg) + +O-RAN ALLIANCE logo + +- [31] 3GPP TS 28.541: “Technical Specification Group Services and System Aspects; Management and orchestration; 5G Network Resource Model (NRM);”, Release 16. +- [32] 3GPP TS 28.620: “Telecommunication management; Fixed Mobile Convergence (FMC) Federated Network Information Model (FNIM) Umbrella Information Model (UIM)”, Release 11.” +- [33] 3GPP TS 28.622: “Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Information Service (IS)” +- [34] 3GPP TS 28.623: “Telecommunication management; Generic Network Resource Model (NRM) Integration Reference Point (IRP); Solution Set (SS) definitions” +- [35] O-RAN WG1 Network Slicing Architecture +- [36] 3GPP TS 32.300: “Telecommunication management; Configuration Management (CM); Name convention for Managed Objects” +- [37] IETF Network Slice Service YANG Model (<https://datatracker.ietf.org/doc/draft-wd-teas-ietf-network-slice-nbi-yang/>) +- [38] YANG Data Models for 'Attachment Circuits'-as-a-Service (ACaaS) (<https://datatracker.ietf.org/doc/html/draft-boro-opsawg-teas-attachment-circuit>) + +## 2.2 Informative references + +References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies. + +NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long-term validity. + +The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. + +- [i1] BBF TR-416 +- [i2] BBF TR-385: ITU-T PON YANG Modules +- [i3] BBF TR-383: Common YANG Modules +- [i4] TR-402: Functional Model for PON Abstraction Interface <https://www.broadband-forum.org/download/TR-402.pdf> +- [i5] TR-403: PON Abstraction Interface for Time-Critical Applications +- [i6] 3GPP TR 28.801: “Telecommunication management; Study on management and orchestration of network slicing for next generation network” +- [i7] 3GPP TR 32.828: “Telecommunication management; Study on alignment of 3GPP generic Network Resource Model (NRM) Integration Reference Point (IRP) and the Telecom Management Forum (TMF) Shared Information/Data (SID) model” + +# 3 Definition of terms, symbols and abbreviations + +## 3.1 Terms + +For the purposes of the present document, the following terms apply: void + +## 3.2 Symbols + +None + +## 3.3 Abbreviations + +For the purposes of the present document, the abbreviations given apply. Abbreviations defined in this document take precedence over the definition of 3GPP. + +| | | +|-------|-----------------------------------------| +| AF | Application Function | +| AMF | Access and Mobility Management Function | +| AN | Access Node | +| ARP | Address Resolution Protocol | +| BBU | Baseband Unit | +| BH | Backhaul | +| BiDi | Bidirectional | +| BS | Base Station | +| BW | Bandwidth | +| CAPEX | Capital Expense | +| CBS | Committed Burst Size | +| CFP | Common Form factor Pluggable | +| CIR | Committed Information Rate | +| CN | Core Network | +| CoMP | Cooperative Multipoint | +| CP | Control Plane | +| CPRI | Common Public Radio Interface | +| CU | Central Unit | +| DC | Data Center | +| DL | Downlink | +| DN | Data Network | +| DHCP | Dynamic Host Configuration Protocol | +| DSCP | Differentiated Services Codepoint | +| DU | Distributed Unit | +| eCPRI | evolved Common Public Radio Interface | +| eMBB | enhanced Mobile Broadband | +| eNB | Enhanced NodeB | +| EP | Ethernet Private | +| EPC | Enhanced Packet Core | +| EPL | Ethernet Private Line | +| EVP | Ethernet Virtual Private | +| EVPL | Ethernet Virtual Private Line | +| FDD | Frequency Division Duplexed | +| FFO | Fractional Frequency Offset | +| FFS | For Further Study | +| FH | Fronthaul | + +![O-RAN ALLIANCE logo](cc3b132d5e82e6f10c355d04ff55855e_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient, followed by 'RAN' in blue and 'ALLIANCE' in smaller blue letters below. + +O-RAN ALLIANCE logo + +| | | +|-------|---------------------------------------------| +| FLR | Frame Loss Ratio | +| FM/PM | Fault and Performance management | +| FR1 | Frequency Range 1 | +| FR2 | Frequency Range 2 | +| FTTH | Fiber To The Home | +| gNB | gNodeB | +| gNMI | Google Network Management Interface | +| GNSS | Global Navigation Satellite System | +| GPRS | General Packet Radio Service | +| GTP | GPRS Tunnelling Protocol | +| ICMP | Internet Control Message Protocol | +| IoT | Internet of Things | +| IP | Internet Protocol | +| IQ | Inphase Quadrature | +| ITU-T | International Telecom Union-Telecom | +| LAN | Local Area Network | +| LTE | Long Term Evolution | +| MAC | Medium Access Layer | +| MPLS | Multi Protocol Label Switching | +| MIMO | Multiple Inputs Multiple Outputs | +| MNO | Mobile Network Operator | +| NGMN | Next Generation Mobile Network | +| NR | New Radio | +| NSA | Non-Stand Alone | +| NSSI | Subnet Networking Slices Instance | +| OAM | Operation Administration Maintenance | +| O-CU | O-RAN Central Unit | +| O-DU | O-RAN Distributed Unit | +| OPEX | Operation Expense | +| ORU | O-RAN Radio Unit | +| PCF | Policy Control Function | +| PDCP | Packet Data Convergence Protocol | +| PRTC | Primary Reference Telecom Clock | +| PTP | Precision Time Protocol | +| OFDM | Orthogonal Frequency Division Multiplexing | +| QAM | Quadrature Amplitude Modulation | +| QoS | Quality of Service | +| QSFP | Quad SFP | +| RB | Resource Block | +| ROADM | Reconfigurable Optical Add Drop Multiplexer | +| RRH | Remote Radio Head | +| RU | Radio Unit | +| SCTP | Stream Control Transmission Protocol | +| SDN | Software Defined Networking | +| SFF | Small Form Factor | +| SFP | Small Form factor Pluggable | +| SLA | Service Level Agreement | +| T-BC | Telecom Boundary Clock | +| TDD | Time Division Duplexing | +| TE | Time Error | +| T-GM | Telecom Ground Master | +| TN | Transport Node | +| T-TSC | Telecom Time Slave Clock | +| TX | Transmit | + +![O-RAN ALLIANCE logo](ab3072b64998ed96600a43311ecd2f44_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN' in blue, with 'ALLIANCE' in smaller blue capital letters below it. + +O-RAN ALLIANCE logo + +| | | +|-----|-----------------------------| +| UDP | User Datagram Protocol | +| UE | User equipment | +| UL | Uplink | +| UNI | Universal Network Interface | +| UPF | User Plane Function | +| VPN | Virtual Private Network | + +# --- 4 Modelling Schema + +The following gives requirements for Modelling Schemas. + +For Modelling Schema implementations, + +- models shall use YANG RFC 7950 [1] as schema. +- models should be under open-source license. +- models shall have modular structure with clearly defined augmentation mechanism. +- models selected shall be independent of specific supplier attributes. +- vendor specific augmentations shall be temporary only, where temporary is defined here as less than one year. +- models should support backwards compatibility and future proof enhancement solution. + +# 5 Device Communication Protocols + +This section defines the communication Protocols for Configuration management, Fault and Performance management and lifecycle management. + +## 5.1 Configuration Management + +Configuration management (CM) shall use YANG schema in conjunction with NETCONF protocol (RFC6241 [2]). Security for NETCONF may either be configured over SSH [3] or TLS [4]. See [5] for additional security requirements for NETCONF. + +Configuration management + +- shall support NETCONF over SSH, according to [5], subsection 2.1. +- should support NETCONF over TLS. +- if NETCONF over TLS is supported, TLS shall be supported according to [5] + +## 5.2 Fault and Performance management + +The following section gives requirements for various transport mechanisms, for Fault and Performance management (FM/PM) models and protocols. + +One option is to use NETCONF also for FM/PM, which has the advantage of only having to implement a single protocol on a network element. Another popular method for retrieving PM/FM is streaming telemetry. The most widely used protocol there is OpenConfig's streaming telemetry using the gNMI protocol [6]. Another emerging standard is streaming using VES (VNF event streaming), defined by OPNFV and ONAP [7], which is already used in O-RAN. + +Fault and performance management: + +- Fault management shall support either NETCONF, gNMI or VES streaming. +- Performance management shall support either NETCONF, gNMI or VES streaming. + +## 5.3 Life cycle management + +Life cycle management: + +- Model shall support life cycle management functions, supported with a single NETCONF interface. +- The model should support full-service lifecycle as specified in the ONAP Architecture, ITU G8052.1 or the MEF 22.3.1 Transport Service Orchestration and Lifecycle Service Orchestration Framework. + +# Annex A (informative) + +# 1 Transport Technology dependent analysis + +Below, we will walk through the different transport technologies and first look at what features a typical commercial system contains and then cover the models that have been implemented commercially and compare the feature set they cover. + +## 1.1 Microwave transport + +Table 1 lists the features in a typical commercial microwave system. + +| Features | | | Microwave | +|----------|-------------------------|-----------------------|-----------| +| CM | Interfaces | Ethernet | x | +| | | Structure | x | +| | | AirInterface | x | +| | | WireInterface | x | +| | | TDM | x | +| | Equipment | Shelf | x | +| | | Card | x | +| | | Slot | x | +| | | Port (SFP, RJ45 etc.) | x | +| | | | | +| | FW/SW Management | | x | +| | Database backup/restore | | x | +| | Traffic protection | | x | +| | Synchronization | | x | +| FM | | | x | +| PM | | | x | +| Security | User management | | x | +| | Certificate handling | | x | + +Table 1 - features in a typical commercial microwave system + +Table 2 compares the models in commercially available microwave systems. + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +| Features | | | ONF Core 1.4 and PACs<br>(TR532 v 2.0 - drafts) | ietf-microwave-radio-link<br>(RFC8561) and ietf<br>models | +|----------|-------------------------|-----------------------|-------------------------------------------------|----------------------------------------------------------------| +| CM | Interfaces | Ethernet | x | x (including ietf-interfaces and other ietf models) | +| | | Structure | x | x (including ietf-interfaces and other models) | +| | | AirInterface | x | x (including ietf-interfaces) | +| | | WireInterface | x | covered by ieee802-ethernet-interface.yang and ietf-interfaces | +| | | TDM | x | x | +| | Equipment | Shelf | x | covered by ietf-hardware | +| | | Card | x | covered by ietf-hardware | +| | | Slot | x | covered by ietf-hardware | +| | | Port (SFP, RJ45 etc.) | x | covered by ietf-hardware | +| | FW/SW Management | | x | x | +| | Database backup/restore | | | | +| | Traffic protection | | x | x | +| | Synchronization | | x | covered by ietf-ptp | +| FM | | | x | covered by ietf-alarms | +| PM | | | x | x | +| Security | User management | | | | +| | Certificate handling | | | | + +**Table 2 - models' comparison in commercially available microwave systems** + +A comparison was done between models which can be used to represent microwave systems: on one side the ONF Core Model version 1.4 [8], along with the different technology specific packages (PACs) defined in [TR532 version 2.0](#) (still a draft version) [9] and on the other side the ietf-microwave-radio-link model ([RFC8561](#)) [10] and other IETF models. + +For describing equipment information, the compared models have a somewhat similar approach: + +- ietf-hardware abstracts any type of component (while the type is an extensible enumeration), while the core-model differentiates in each equipment instance between connectors and contained-holders (while the type is just a string, so a flexibility for vendors, but can result in different approaches for different vendors), +- ietf-hardware can contain sensor data, which is rather abstract and lets vendors build any type of data, which can result in different approaches for different vendors, while the ONF Core Model does not include sensor data, +- ONF Core Model differentiates between actual and expected equipment, which is not the case in the ietf-hardware, +- ietf-hardware provides *some* information about revisions (hardware, software etc.) and hardware information, while the ONF Core Model provides a lot more details about the hardware (physical, mechanical, spatial, environmental etc.), +- both models offer parent-child relationships between the equipment instances for describing an entire hierarchy. + +For describing interfaces and their attributes, the comparison focused on ietf-interfaces model (augmented by ietf-microwave-radio-link) and the ONF Core Model augmented by different technology specific PACs): + +- the ietf-interfaces are only augmented to provide air-interfaces (microwave specific parameters), while the ONF Core Model is augmented to provide different types of interfaces (air-interfaces, ethernet containers, wire-interfaces, even MAC and VLAN interfaces) + +![O-RAN ALLIANCE logo](cc3b132d5e82e6f10c355d04ff55855e_img.jpg) + +O-RAN ALLIANCE logo + +- the ietf-interfaces model is augmented with approximately 50 microwave specific parameters that describe capabilities, performance, configuration, and status, while the ONF Core Model is augmented with approximately 175 microwave specific parameters which cover capabilities, performance (historical and current), configuration, status and current problems (alarms/faults). The current problems which are missing from the ietf-interfaces could be covered by the ietf-alarms yang model +- both ietf-interfaces and the ONF Core Model support layering of interfaces (higher and lower layer, and respectively client-server relationships) +- ietf-interfaces modelling is compliant with the NMDA (Network Management Datastore Architecture – [RFC8342](#)), [section 5.3](#), while the augmentations for the ONF Core Model are not. To be more precise, section 5.3 of RFC8342 states that the *operational* datastore is a read-only datastore which consists of all “config false” and “config true” attributes defined in the yang models (while the original NETCONF specification indicated that the *operational* datastore may contain only “config false” parameters). The advantage of the new approach is that it enables the ability of nodes to expose all operational settings without needing to replicate definitions in the data model. The modelling of ietf-interfaces complies with this architecture, while the core-model defines different attributes for configuration and for status of a particular configuration. + +For group definitions, the comparison focused on the ietf-microwave-radio-link and augmentations for the ONF Core Model: + +- the ietf-microwave-radio-link describes XPIC and MIMO groups, while augmentation of core-model describe also ALIC (Adjacent Link Interference Calculation) groups + +Both models describe radio link protection groups, with the difference that in the ietf model the type of group is an extensible enumeration, while in the ONF Core Model the type is just a string. + +For FW/SW Management, mature YANG models do not exist yet. Inside the ONF there are ongoing discussions for providing such capabilities for microwave systems, but a draft YANG model is yet to be provided. + +From the user management and certificate handling perspective, a generic model that allows a centralized control does not exist yet. Each individual node can nevertheless rely on the standard NETCONF Server models for that purpose, there is no need for having a microwave specific model. + +Both the ONF Core Model with its technology specific augmentations and the IETF models, which were part of the comparison, could be used to describe the management interface of a microwave system. Both models have gaps in their air-interface and in the network interface attributes, which need to be communicated to relevant standard groups for future consideration. The ONF model strives for a complete set of harmonized attributes, in order to prevent need for proprietary augmentations. The IETF model focuses on a smaller set of attributes which describe an air-interface, but which would cover a big amount of use cases, while allowing proprietary augmentations for attributes which are not yet considered in the model. The IETF core model is designed with flexibility in mind taking advantage of the wealth of features and models developed across the IETF/IEEE std organizations especially the one related to models supporting many packet-based features, while maintaining strict backwards compatibility to its Core Model and YANG versioning modules that require updating a published YANG module to follow the rules in clause 11 of the IETF RFC 7950 [1] prohibiting Non-Backwards Compatible (NBC) changes. Models describing other types of interfaces present in microwave systems (wire interfaces, ethernet, VLAN etc.) exist both in ONF (proposed as augmentations for the ONF Core Model) and in the IETF, but they were not part of the gap analysis. + +## 1.2 Optical access + +The optical access refers to an optical fiber equipment and infrastructure lying between an optical termination (here, typically the antenna cell site) and the central office (aggregation node). Optical line termination (OLT) and Optical Network Unit (ONU) are the active equipment which serve as the service provider endpoints at + +![O-RAN ALLIANCE logo](cc3b132d5e82e6f10c355d04ff55855e_img.jpg) + +O-RAN ALLIANCE logo + +each end of the access passive optical network. The OLT shelf supports two different medium connectivity based on specific cards & interfaces. + +- i. The first one is the PON (Passive Optical network) which is used for FTTHome based on PtMP optical infrastructure (also named ODN optical Distribution network). Several PON generations are available: G-PON (Gigabit capable Passive Optical Network), XGS-PON (10 Gigabit symmetrical capable Passive Optical Network), and the coming HS-PON (High-Speed capable Passive Optical Network). +- ii. The second supported connectivity at OLT is Ethernet PtP based on regular transceivers. This PtP interfaces are used for business and the existing mobile backhaul. + +So an OLT is an equipment which supports these two types of access interfaces to reach customers, a backplane, one or several uplinks port to reach metropolitan nodes and a management. + +Ideally, the management plane of an OLT is desired natively to be vendor agnostic. If it were the case, all operational procedures would be defined once and used and reused for all the equipment of a given type. Over the last decades, attempts for standardizing the management interfaces of the network elements have been largely unsuccessful. Consequently, proprietary management systems are commonly used. This obliges the operator to adapt its OSS (Operations Support System) to different proprietary management interfaces, which is time consuming and requires quite a significant effort in terms of OSS development. But for this new decade, things are changing. Thanks to the emergence of SDN and the lobbying efforts from network service providers to better automate its operational processes, the introduction of software in the telecommunication industry gives SDAN (Software- Defined Access Network) solutions and opportunity allowing telcos to manage the access nodes themselves as well as create new kinds of orchestration at the service layer. Last but not least, the SNMP (Simple Network Management Protocol) management protocol and its associated data-modelling language in use today are pretty old and were inherently not well designed to comply with data-models promoted by the standards. SNMP is also currently used for pulling statistics and counters from the network elements (performance monitoring, troubleshooting). However, SNMP is not well designed for massive data collections. NETCONF (Network Configuration Protocol) interfaces and YANG (Yet Another Next Generation) data-models for PON are now proposed (cf. IETF RFC 6241 [2] and BBF TR385 [13], respectively). They are gaining some momentum so we forecast that they will replace SNMP. The coming decade will correspond to a network migration and operation with natively NETCONF/YANG access equipment leveraging on a clear separation between the network node management layer and the service design and management layer. + +Two references implementation are proposed for SDAN by: + +- i. Open Network Foundation with SDN-Enabled Broadband Access (SEBA) including Virtual OLT Hardware Abstraction (VOLTHA) +- ii. Broad Band Forum with Cloud Central Office (Cloud CO) including BBF's Access Abstraction Layer (BAA). Cloud CO is standardized, as for the use cases which are proposed under BBF's "TR-416 [i1]: Cloud CO Use Cases and Scenarios". + +### 1.2.1 TDM-PON + +ONU management and control interface (OMCI) is defined in the ITU-T specification G.988 [11]. + +Table 3 lists the features in a typical commercial TDM-PON system: + +| Features | | | PON | +|----------|---------------------------------------------|------------------------|---------| +| | | | OLT/ONU | +| CM | MOI (generic handling) | Create, Delete, modify | x | +| | | LCM | x | +| | | states | x | +| | Interfaces and termination points | | x | +| | Synchronization (NTP, PTP) | | x | +| | Inventory (HW) | | x | +| | Software | Software Management | x | +| | | Software Inventory | x | +| | Database backup/restore | | x | +| | Traffic protection | equipment | x | +| | | traffic | x | +| FM | supervision | | x | +| | Management (f4 integration time, ASAP, ...) | | x | +| | Inventory (AlarmTypeIDs) | | x | +| | History (log) | | x | +| PM | Supervision | | x | +| | Management | | x | +| | Inventory | | x | +| | Threshold | | x | +| | History | | x | +| Security | User management | | x | +| | Access control | | x | +| | Certificate handling | | x | + +**Table 3 - features in a typical commercial TDM-PON system** + +Table 4 compares the models in commercially available TDM-PON systems: + +![O-RAN ALLIANCE logo](100c8b2e5e489241b0a39f73a8896fd5_img.jpg) + +O-RAN ALLIANCE logo + +| Features | | | PON | +|----------|---------------------------------------------|------------------------|---------------------------------| +| | | | BBF | +| CM | MOI (generic handling) | Create. Delete, modify | x | +| | | LCM | | +| | | states | By ietf-interfaces | +| | Interfaces and termination points | | ietf-interfaces augmented | +| | Synchronization (NTP, PTP) | | Gpon2-ptp | +| | Inventory (HW) | | x | +| | Software | Software Management | | +| | | Software Inventory | | +| | Database backup/restore | | | +| | Traffic protection | equipment | | +| | | traffic | (x) | +| FM | supervision | | Via well-defined notifications | +| | Management (f4 integration time, ASAP, ...) | | | +| | Inventory (AlarmTypeIDs) | | YANG enums | +| | History (log) | | | +| PM | Supervision | | By TCAs | +| | Management | | x | +| | Inventory | | By YANG | +| | Threshold | | x | +| | History | | x | +| Security | User management | | No, usage of NACM | +| | Access control | | No, usage of NACM | +| | Certificate handling | | No – NetConf/SSH, TLS, Callhome | + +**Table 4 - Models comparison of commercially available TDM-PON systems** + +In the TDM-PON space, there is only one model from the broadband forum (BBF) [12,i2,i3] that has been commercially implemented. So, the recommendation here is to use this interface for this purpose. + +The Broadband Forum also worked on defining a functional model for PON abstraction interface and a PON abstraction interface for time-critical application: + +- **TR-402** [i4] Functional Model for PON Abstraction Interface <https://www.broadband-forum.org/download/TR-402.pdf> +- **TR-403** [i5] PON Abstraction Interface for Time-Critical Applications + +Finally, it was proposed to standardize the transport of the ONU Management and Control Interface (OMCI) ITU-T G.988 Amendment 3 – 03/2020 [11] over Ethernet through the 'Standard for Management Channel for Customer-Premises Equipment Connected to Ethernet-based Subscriber Access Networks', in the IEEE 1904.2 Task Force [13]. This standard allows remote device management, used for commercially available miniature pluggable SFP-OLTs where several control and management functions are run on commodity servers, remotely from the pluggable SFP-OLTs. + +### 1.2.2 Point-to-point interfaces + +For Point-to-point interfaces, we recommend to also use the ONU Management and Control Interface (OMCI) over Ethernet through the 'Standard for Management Channel for Customer-Premises Equipment Connected to Ethernet-based Subscriber Access Networks', in the IEEE 1904.2 Task Force [13]. This implementation allows to use the existing PON management mechanism for PtP with a master equipment (at the central office (OLT with PtP interface)) and a slave equipment (at the antenna site (PtP ONU)). + +### 1.2.3 WDM-PON + +ITU-T SG15 Q2 launched a study item to clarify requirements and specifications for the new WDM-PON Recommendation management channel. The approach to implement management channel is under discussion based on: + +1. Transparent approach: This approach doesn't touch the bit-stream of client signal and is basically specific to the bitrate and protocol of client signal. An example of this approach is Transparent AMCC (Auxiliary Management and Control Channel) defined in G.989.2 [14]. Another example of this is HTMC (head-to-tail message channel) defined in G.698.4 [15]. + +2. Unified-frame approach: This approach maps the bit-stream of client signal onto a frame defined in the PON layer. Management information is also carried by the frame defined in the PON layer. An example of this approach is the TC frame with PLOAM and OMCI. + +Then, the following approaches seem something in between. + +3. Transcoded AMCC: This is defined in G.989.3 [16] and mentioned in G.9806 [17]. It is (almost) transparent for signals using for example 8B10B or 64B66B coding but cannot accommodate other protocols. + +4. OAM mapped into Ethernet frames: This is defined in defined in G.9806 [17]. It adds local OAM information into Ethernet frames but cannot accommodate to protocols other than Ethernet. Also, we need a design rule for sharing the bandwidth between the client frames and the management frames. + +## 1.3 Optical transport + +### 1.3.1 Fronthaul WDM systems + +This section looks at Fronthaul WDM systems. More info can be found in the WDM requirements document. + +#### Passive-passive + +Since this is a fully passive configuration, no management interfaces are needed. An optional implementation is to keep passive the fronthaul channels transmission and to add in parallel a dedicated loopback physical channel for supervision of the trunk (between wavelength multiplexer) fiber infrastructure. This loop back is + +![Diagram of a Passive-passive Fronthaul WDM system. The diagram shows a Management system connected via Netconf to a Fiber supervision with dedicated loopback physical channel. This channel includes a Tx (Transmitter) and Rx (Receiver) connected to a WDM (Wavelength Division Multiplexer). The WDM is connected to O-DU (Optical Data Unit) and O-RU (Optical Remote Unit) via a Loopback. A double-headed arrow labeled OAM (Optical Access Management) indicates the supervision channel between the WDM and the O-RU/O-DU.](9c5e1cf6a447cf6840f08c864b6de497_img.jpg) + +Diagram of a Passive-passive Fronthaul WDM system. The diagram shows a Management system connected via Netconf to a Fiber supervision with dedicated loopback physical channel. This channel includes a Tx (Transmitter) and Rx (Receiver) connected to a WDM (Wavelength Division Multiplexer). The WDM is connected to O-DU (Optical Data Unit) and O-RU (Optical Remote Unit) via a Loopback. A double-headed arrow labeled OAM (Optical Access Management) indicates the supervision channel between the WDM and the O-RU/O-DU. + +passive in the antenna location and active for only this supervision channel (not active for the fronthaul channels). Management aspects of the transceivers must be captured where they are integrated into end points (e.g., mplane [18]). Table 5 shows the interface functional requirements. + +| Functions | | | Passive-<br>Passive | +|-----------|----------------------------|-------------------------|---------------------| +| CM | system | Topology | x | +| | | Connection | x | +| | WDM equipment | Information query | | +| | | Equipment configuration | | +| | Transceiver | Protection management | x | +| | | Information query | | +| FM | WDM equipment | Configuration | | +| | | | | +| | Transceiver | | | +| | | | | +| PM | Fiber trunk infrastructure | | x | +| | | | | +| | | | | +| Security | WDM equipment | | | +| | Transceiver | | | +| | Fiber trunk infrastructure | | x | +| Security | User management | Netconf password config | x | +| | Certificate handling | | x | + +**Table 5 - The interface functional requirements for Passive-active system with fiber trunk supervision** + +#### Passive-active + +The semi-active WDM solution is composed of optical modules, passive WDM equipment at the remote O-RU side and the active WDM equipment at O-DU side of the central office. For management capability of the network, the management and control system could send management requests to the active WDM equipment through the management interface and manage the semi-active WDM system, including query and configuration. + +#### *Semi-active type I* + +![Diagram of Semi-active type I WDM solution architecture.](2be76a848bb89bce5c7680358ed46405_img.jpg) + +The diagram illustrates the architecture of a semi-active WDM solution (Type I). At the top, a grey box represents the 'Management system'. Below it, on the left, are three O-RU units, each consisting of an antenna and a transceiver. These are connected via a rainbow-colored optical signal to a passive WDM component (represented by a prism). This passive component is part of a larger dashed box labeled 'OAM' (Optical Access Module). The signal then travels through an active WDM component (represented by a blue box with a double arrow) to the O-DU (Optical Distribution Unit) on the right, which is shown as a server rack. A 'Netconf' line connects the Management system to the active WDM component. A double-headed arrow at the bottom indicates the 'OAM' span across the optical path. + +Diagram of Semi-active type I WDM solution architecture. + +The O-DU is transparent to the wavelength transmission features and the O-RU supports the WDM transceiver. The management and control system could control the wavelength assignment and also could + +![O-RAN ALLIANCE logo](50e2be491896a20a2a0d457d4e7bc868_img.jpg) + +O-RAN ALLIANCE logo + +interconnect with the active WDM equipment at O-DU side to manage the WDM system through management interface, including query and configuration. The active WDM equipment plays a master role and could manage the WDM transceiver at O-RU side by an embedded OAM channel. + +#### *Semi-active type II* + +![Diagram of Semi-active type II architecture. A Management system is connected via Netconf to a Power detector. The Power detector is connected to a WDM transceiver. The WDM transceiver is connected to O-DU equipment. The O-RU side is connected to the WDM transceiver via an OAM channel. The OAM channel is represented by a large arrow pointing from O-RU to O-DU.](df9278566c2807beaff1feb638061500_img.jpg) + +Diagram of Semi-active type II architecture. A Management system is connected via Netconf to a Power detector. The Power detector is connected to a WDM transceiver. The WDM transceiver is connected to O-DU equipment. The O-RU side is connected to the WDM transceiver via an OAM channel. The OAM channel is represented by a large arrow pointing from O-RU to O-DU. + +The O-RU and O-DU both support the WDM transceivers. The management and control system could control the wavelength assignment and also could interconnect with the active WDM equipment at O-DU side to monitor the WDM system through management interface. The active WDM equipment plays a master role and could monitor the WDM transceiver at both O-RU and O-DU sides by an embedded OAM channel. Table 6 shows the interface functional requirements. + +| Functions | | | Semi-active type I | Semi-active type II | +|-----------|----------------------|-------------------------|--------------------|---------------------| +| CM | system | Topology | × | × | +| | | Connection | × | × | +| | WDM equipment | Information query | × | × | +| | | Equipment configuration | × | × | +| | | Protection management | × | × | +| | Transceiver | Information query | × | | +| | | Configuration | × | | +| FM | WDM equipment | | × | × | +| | Transceiver | | × | × | +| PM | WDM equipment | | × | × | +| | Transceiver | | × | × | +| Security | User management | Netconf password config | × | × | +| | Certificate handling | | × | × | + +**Table 6 - The interface functional requirements for Semi-active system** + +![O-RAN ALLIANCE logo](07ee376ad62709c90a4d80978b3c05de_img.jpg) + +O-RAN ALLIANCE logo + +##### Active-active + +This configuration has both ends fully active and uses management interfaces. In this configuration, there is an Optical Supervisory Channel (OSC). + +Table 7 compares features of Fronthaul WDM system features. + +| Features | | | WDM Fronthaul | | +|----------|-------------------------|----------------------|-----------------------|------| +| | | | Common Shelf (active) | TPDR | +| CM | Interfaces | Ethernet | | x | +| | | OTS/OMS | X (active-active) | | +| | | OCH | x | x | +| | | OSC | X (active-active) | | +| | Equipment | Shelf | x | x | +| | | Card | x | x | +| | | slot | x | x | +| | | subslot | x | x | +| | | port | x | x | +| | FW/SW update | | x | x | +| | Database backup/restore | | x | x | +| | Path protection | | x | x | +| | synchronization | | TBD | TBD | +| FM | | | x | x | +| PM | | | x | x | +| Security | User management | Multi-user hierarchy | x | x | +| | Certificate handling | | x | x | + +Table 7 - Feature comparison of WDM Fronthaul Systems + +Table 8 shows the comparison for models for Fronthaul WDM system. + +| Features | | | WDM Fronthaul | | +|----------|-------------------------|----------------------|-----------------------|------| +| | | | Common Shelf (active) | TPDR | +| CM | Interfaces | Ethernet | | x | +| | | OTS/OMS | X (active-active) | | +| | | OCH | x | x | +| | | OSC | X (active-active) | | +| | Equipment | Shelf | x | x | +| | | Card | x | x | +| | | slot | x | x | +| | | subslot | x | x | +| | | port | x | x | +| | FW/SW update | | x | x | +| | Database backup/restore | | x | x | +| | Path protection | | x | x | +| | synchronization | | TBD | TBD | +| FM | | | x | x | +| PM | | | x | x | +| Security | User management | Multi-user hierarchy | x | x | +| | Certificate handling | | x | x | + +**Table 8 - Comparison of models for WDM Fronthaul Systems** + +Here are the gaps for the three different models for Transceivers (comparing May 2020 models): + +OpenConfig [18] + +- 25G Wavelengths missing. + +OpenROADM [19] + +- No 10G or 25G on-off keyed wavelength support, +- No lldp snooping, +- Only rudimentary tracking of client modules. + +M-Plane [20] + +- Only supports application where transceiver is plugged into O-DU/O-RU + +![O-RAN ALLIANCE logo](99be9500d936730cac909cdccf03deeb_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN ALLIANCE' in blue and green. + +O-RAN ALLIANCE logo + +Here are the gaps for the different models for WDM fronthaul common equipment: + +#### OpenConfig + +- Subslot missing as explicit item, +- No individual pack FW update, only whole NE SW, +- OSC modeled only on amplifier, +- EMS required for lamp test, +- Database backup / restore is via Netconf read / write config, +- Streaming telemetry no historic data, +- No explicit wavelength dependent port. + +#### OpenROADM + +- OSC is Ethernet only, no SONET, +- OSC assumes lldp from other end (problem for passive-active?), +- No path protection defined. + +#### M-Plane + +- WDM common equipment not defined at all. + +The following recommendation shows how the models can be used based on where the optics are located: + +| | | +|----------------------------------|--------------------------------------------------| +| Transceiver inside O-DU/O-RU | Use M-plane | +| Transceiver inside router/switch | Use OpenConfig or IETF (see IP/Ethernet section) | +| Transceiver inside transponder | Use OpenConfig or OpenROADM | + +For the common equipment the following recommendation can be used: + +| | | +|-----------------------------------------|----------------| +| If supplier already supports OpenConfig | Use OpenConfig | +| If supplier already supports OpenROADM | Use OpenROADM | + +![O-RAN ALLIANCE logo](99be9500d936730cac909cdccf03deeb_img.jpg) + +O-RAN ALLIANCE logo + +### 1.3.2 Mid- and backhaul ROADM transport + +This section covers the optical transport needs for mid- and backhaul fiber optic systems. The assumptions are that these fiber optic transport systems are multi-point systems and therefore need reconfigurable add/drop capability, known as ROADMs. Table 9 lists the features in a typical commercial ROADM system. + +| Features | | | ROADM systems | | +|----------|-------------------------|----------|---------------|------| +| | | | ROADM | TPDR | +| CM | Interfaces | Ethernet | | x | +| | | OTN | | x | +| | | OTS/OMS | x | | +| | | OCH | x | x | +| | | OSC | x | | +| | Equipment | Shelf | x | x | +| | | Card | x | x | +| | | slot | x | x | +| | FW/SW update | | x | x | +| | Database backup/restore | | x | x | +| | Logging (like syslog) | | x | x | +| | DCN management | | x | x | +| | File management | | x | x | +| | OTDR | | x | | +| | Traffic protection | | x | x | +| | synchronization | | | | +| FM | | | x | x | +| PM | | | x | x | +| Security | User management | | x | x | +| | Certificate handling | | x | x | + +**Table 9 - Feature list for commercial ROADM systems** + +Table 10 compares the models in commercially available ROADM systems. + +| Features | | | ROADM systems | | +|----------|-------------------------|----------|---------------------|-----------| +| | | | OpenConfig | OpenROADM | +| CM | Interfaces | Ethernet | x | x | +| | | OTN | x | x | +| | | OTS/OMS | x | x | +| | | OCH | x | x | +| | | OSC | x | x | +| | Equipment | Shelf | x | x | +| | | Card | x | x | +| | | slot | x | x | +| | FW/SW update | | SW | x | +| | Database backup/restore | | | x | +| | Logging (like syslog) | | x | x | +| | DCN management | | x | (x) | +| | File management | | x | x | +| | OTDR | | x | x | +| | Traffic protection | | x | x | +| | synchronization | | | | +| FM | | | x | x | +| PM | | | Streaming telemetry | x | +| Security | User management | | x | x | +| | Certificate handling | | x | x | + +**Table 10 - Model comparison for commercial ROADM systems** + +In terms of comparison of the two options, the main difference between OpenConfig and OpenROADM are the assumptions of the SDN architecture behind the use cases. + +In the case of OpenConfig, there is an assumption that there exists a vendor controller for the ROADM switches<sup>1</sup>, where the end-to-end path through the ROADM network is configured through the vendor controller (see Figure 1). The transponders are directly controlled from the SDN Controller via OpenConfig interfaces. + +<sup>1</sup> this architecture is sometimes called “partial disaggregation”, and standards such as ONF Transport API are available for the API to the vendor controller. + +![Figure 1: OpenConfig partial disaggregation configuration. This diagram shows an SDN Controller at the top, connected via API to a Vendor controller and directly to two Transponder units. Each Transponder consists of a 400G Client, a Line Side, and a 400G Client. The Transponders are connected to a central ROADM (Reconfigurable Optical Add-Drop Multiplexer) which is represented by a mesh of four nodes. The ROADM is connected to two Routers, one on each side. The SDN Controller has direct API connections to the Vendor controller and the two Transponder units, while the Vendor controller also has an API connection to the ROADM.](03af190f48050894bf6205a818e8eac4_img.jpg) + +Figure 1: OpenConfig partial disaggregation configuration. This diagram shows an SDN Controller at the top, connected via API to a Vendor controller and directly to two Transponder units. Each Transponder consists of a 400G Client, a Line Side, and a 400G Client. The Transponders are connected to a central ROADM (Reconfigurable Optical Add-Drop Multiplexer) which is represented by a mesh of four nodes. The ROADM is connected to two Routers, one on each side. The SDN Controller has direct API connections to the Vendor controller and the two Transponder units, while the Vendor controller also has an API connection to the ROADM. + +**Figure 1 - OpenConfig partial disaggregation configuration** + +OpenROADM on the other hand assumes that all the elements are disaggregated and can be controlled by a single logical SDN controller using OpenROADM APIs. The devices are directly integrated into the SDN Controller independent of vendor with direct control of line system (see Figure 2). + +![Figure 2: OpenROADM full disaggregation configuration. This diagram shows an SDN Controller at the top, connected via API to four components: the Vendor controller, the two Transponder units, and the ROADM. The Transponder units are identical to those in Figure 1, each containing a 400G Client, a Line Side, and a 400G Client. The ROADM is a central mesh of four nodes. The SDN Controller has direct API connections to the Vendor controller, the two Transponder units, and the ROADM. The Vendor controller also has an API connection to the ROADM.](0a1c2829f6b337ee487b2962b3470cb2_img.jpg) + +Figure 2: OpenROADM full disaggregation configuration. This diagram shows an SDN Controller at the top, connected via API to four components: the Vendor controller, the two Transponder units, and the ROADM. The Transponder units are identical to those in Figure 1, each containing a 400G Client, a Line Side, and a 400G Client. The ROADM is a central mesh of four nodes. The SDN Controller has direct API connections to the Vendor controller, the two Transponder units, and the ROADM. The Vendor controller also has an API connection to the ROADM. + +**Figure 2 - OpenROADM full disaggregation configuration** + +Here are the gaps for the three different models for Transponders (comparing May 2020 models): + +#### OpenConfig + +- 25G Wavelengths missing. + +#### OpenROADM + +- No 10G or 25G on-off keyed wavelength support, + +![O-RAN ALLIANCE logo](99be9500d936730cac909cdccf03deeb_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN ALLIANCE' in blue and green. + +O-RAN ALLIANCE logo + +- No lldp snooping, +- Only rudimentary tracking of client modules. + +Here are the gaps for the different models for WDM common equipment: + +#### OpenConfig + +- No individual pack FW update, only whole NE SW, +- EMS required for lamp test, +- Database backup / restore is via Netconf read / write config, +- Streaming telemetry no historic data. + +#### OpenROADM + +- No path protection defined. + +For the ROADM equipment the following recommendation can be used: + +| | | +|-----------------------------------------------------------|----------------| +| If Network Operator uses single vendor optical controller | Use OpenConfig | +| If Network Operator disaggregates optical commons | Use OpenROADM | + +## 1.4 IP/Ethernet transport + +The intention of this section is to document the research that has been undertaken by the O-RAN WG9 team and provide recommendations relative to the automation and management of O-RAN networks and pertains to the architecture and solutions outlined in WG9's Xhaul Packet Switched Architectures and solutions (O-RAN.WG9.XPSAAS-v03 [21]) and how a slice can be managed. The packet switched transport architecture is illustrated in Figure 3. + +![Figure 3 - Packet switched transport for mobile Xhaul architecture diagram](70afaf934947a8c7529c71b1406a6bba_img.jpg) + +The diagram illustrates the architecture for packet switched transport for mobile Xhaul. It is structured into several layers and components: + +- Top Layer:** A blue box labeled "Transport SDN / Orchestration and Telemetry". +- Service Layer:** An orange box labeled "Mobile Services: MP-BGP EVPN and L3VPN". +- Underlay Layer:** A dark blue box labeled "Underlay transport fabric: MPLS or SRv6, QoS, timing". +- Network Fabric:** A horizontal sequence of components connected by bidirectional arrows: + - Access:** Represented by a radio tower icon. + - Pre-Agg:** A cloud icon. + - Aggregation:** A cloud icon. + - Transport Core:** A cloud icon. +- Data Centers (DC):** Three white boxes labeled "DC" are positioned below the "Pre-Agg", "Aggregation", and "Transport Core" clouds, each connected to the network fabric by a bidirectional arrow. +- External Connections:** + - A "Peering" cloud icon is connected to the "Transport Core" cloud. + - A "Cloud" cloud icon is connected to the "Transport Core" cloud. +- Physical Layer:** Two white boxes at the bottom are labeled "Dark fibre / WDM" and "Dark fibre / switched WDM", representing the underlying transport medium. + +Figure 3 - Packet switched transport for mobile Xhaul architecture diagram + +**Figure 3 - Packet switched transport for mobile Xhaul** + +It is a converged end to end packet switched infrastructure, beginning at the cell site, located in the edge of the access part of the transport layer, and stretching to the core of the transport layer. The packet switching TNEs are IP/MPLS or SRv6 QoS enabled, high capacity, low latency devices interconnected by point-to-point Ethernet interfaces running at the full capacity of the Ethernet interface, typically using either point to point fibres or via a WDM infrastructure. It incorporates data centers suitably placed across the transport network infrastructure to support virtual and physical NFs associated with mobile and fixed services but also potentially the placement of “Application Functions” associated with value-add services and customer specific application. + +The logical architecture is based on a common underlay packet switching infrastructure based on either MPLS or SRv6 overlaid with a L2 / L3 service infrastructure (VPNs) that uses the capabilities of the underlay packet switched network to support the mobiles interfaces. + +The underlay packet switching infrastructure provides basic network services such as any-to-any connectivity between TNEs, scaling, fast convergence, shortest path and traffic engineered forwarding, packet-based Quality of Service (QoS) and timing. + +The service layer supports native Ethernet services, using EVPN technology and IP VPN services, using MP-BGP based L3VPNs. These services can utilise the facilities offered by the underlay packet switched infrastructure to support the different mobile interfaces in an appropriate fashion. Where possible transport services are built on an end-to-end basis without intermediate stitching / switching points within the transport infrastructure. This approach has been taken to minimise the transport service orchestration overhead. + +### 1.4.1 Provisioning and managing a packet switched infrastructure + +There are two main phases associated with the provision and management of a packet switched infrastructure: + +- Building and managing the basic infrastructure. This is a process that occurs when the network is first built and later when new TNEs are installed or when TNEs are modified or upgraded. It covers the basic set-up of devices, the configuration of the management infrastructure, set-up of interfaces, core QoS and routing protocols. This function is undertaken by the network operations team and is normally largely transparent to the users of the network. +- Services configuration and management. In the architecture outlined in Xhaul Packet Switched Architectures and solutions (O-RAN.WG9.XPSAAS-v04 [21]) services, such as a transport slice, are MP-BGP based on L2VPNs and L3VPNs. The construction of a service involves multiple actions and components such as building VPNs, Edge QoS, service level OAM and potentially mapping services to underlay policies. In contrast to the basic infrastructure this is an on-going process and + +![O-RAN ALLIANCE logo](99be9500d936730cac909cdccf03deeb_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN ALLIANCE' in blue and green. + +O-RAN ALLIANCE logo + +constantly changing. The service orchestration and service assurance also need to interact with OSS/BSS components and customers. In this instance a customer can be a human or external orchestration software. Relating this specifically to transport level slicing; the customer might be the NSMF. It also needs to abstract away the topology, complexity, and technology of the actual network infrastructure, so the customer can largely treat the network as a black box offering connectivity and SLAs. + +### 1.4.2 Assessment methodology and analysis + +For the device models, the primary objective from WG9 was to evaluate open standard interfaces that can be used to between the Transport Controller (TSC) to satisfy the requirement for automation on the Xhaul Packet Switched networks as described in O-RAN.WG9.XPSAAS-v04.00 [21]. The types of interfaces fall into several categories: + +- Configuration/operational interfaces (e.g. Netconf/YANG with YANG data model supporting the required functionality) +- Control-plane interfaces (e.g. BGP-LS, PCEP) +- Telemetry interfaces (e.g. Openconfig gRPC or NETCONF) + +To break down the assessment, a list of high-level technology areas was created where interfaces and data models would be required to satisfy the functional requirements for O-RAN. For each of these areas a review was performed to assess the availability and completeness of these interfaces. For each of the categories research was done to assess existence, maturity and completeness of options available in IETF and Openconfig projects as well as the suitability to facilitate automation of the O-RAN proposed architecture. + +The high-level technology areas reviewed were as follows: + +#### Configuration/Operational Interfaces: + +- Hardware Inventory +- L3VPN +- EVPN +- QoS +- SR +- RSVP +- Network Slicing +- Inter-AS +- OAM +- Multicast +- Timing + +#### Control-plane Interfaces: + +- Tunnel Discovery and tunnel CRUD operations +- Topology acquisition and monitoring + +##### Telemetry Interfaces: + +- Performance monitoring +- Fault monitoring + +It was clear from early on in the research that there were two main source areas where significant work has already been undertaken to standardize interfaces that fall into the categories above. Firstly, within the IETF + +![O-RAN ALLIANCE logo](cc3b132d5e82e6f10c355d04ff55855e_img.jpg) + +O-RAN ALLIANCE logo + +there are many different activities that have either been carried out or are work in progress. As per the agreement with WG9 only RFCs and working group drafts will be considered for recommendation (if suitable), however some Internet drafts may be tracked especially if there is a strong indication that they will soon become working group drafts and if they have high relevance to the O-RAN project. Secondly, a good deal of work has taken place within the Openconfig project where a number of network operators work to create common YANG models suitable for common network deployment scenario that can be used across multiple vendor technologies. + +#### 1.4.2.1 Configuration/Operational Interfaces + +##### 1.4.2.1.1 IETF Gap Analysis + +There are a number of working group drafts within the IETF that are possible candidates for use when configuring the network elements. Most of these are still in draft stage and in some cases, there are some gaps which have been identified (see Table 11). + +It is not clear at this time whether there is extensive support for these drafts across the various vendor implementations which could create challenges for real world adoption in the short term. + +| IETF | | | +|--------------|------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------| +| Function | Available Options | Known Gaps | +| HW inventory | ietf-hardware.yang | | +| L3VPN | draft-ietf-bess-l3vpn-yang-05<br>draft-ietf-idr-bgp-model-10 | Extended color community<br>BGP only | +| EVPN | draft-ietf-bess-evpn-yang (expire 2019)<br>draft-ietf-idr-bgp-model-10 | No longer active<br>BGP only | +| QoS | draft-ietf-rtgwg-qos-model-03 | | +| SR | draft-ietf-spring-sr-yang-30 | Limitations in the areas of SRv6, sBFD, BSID, FlexAlgo (expired draft exists for flex-algo draft-rasool-lsr-flex-algo-yang-01) | +| Inter-AS | draft-ietf-idr-bgp-model-10 | ORF (recommendation in the packet switched architecture document) | +| OAM | No specific module for OAM | Remote execution of troubleshooting tools (e.g. ping, traceroute, MPLS/SR ping) | +| Multicast | draft-ietf-bess-mvpn-yang-05 | | +| Timing | Rfc8575? | | +| | | | + +**Table 11 - IETF YANG Models for Configuration** + +##### 1.4.2.1.2 Openconfig Gap Analysis + +The research which was undertaken also reviewed the available YANG models within the Openconfig project. Table 12 shows the models that were reviewed: + +| Openconfig | | | +|--------------|-----------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------| +| Function | Available Options | Known Gaps | +| HW inventory | openconfig-platform.yang | | +| L3VPN | openconfig-bgp-common-multiprotocol.yang<br>openconfig-interfaces.yang<br>openconfig-network-instance.yang<br>openconfig-bgp-types.yang | | +| EVPN | openconfig-bgp-common-multiprotocol.yang<br>openconfig-interfaces.yang<br>openconfig-network-instance.yang<br>openconfig-bgp-types.yang | | +| QoS | openconfig-qos.yang | | +| SR | openconfig-segment-routing.yang<br>openconfig-pf-srte.yang | SRv6 and Flex-Algo | +| Inter-AS | openconfig-bgp-common-multiprotocol.yang | ORF (recommendation in the packet switched architecture document) | +| OAM | No specific module for OAM | Remote execution of troubleshooting tools (e.g. ping, traceroute, MPLS/SR ping) | +| Multicast | openconfig-pim.yang<br>openconfig-igmp.yang | No support found for MVPN or other MPLS Multicast applications | +| Timing | | No module for timing configuration found | +| | | | + +Table 12 - Openconfig YANG Models for Configuration + +While there appears to be good coverage in some areas like VPN technologies there are also gaps in some important areas like SRv6 and Flex Algo. + +##### 1.4.2.1.3 Native YANG models + +All vendors typically have their own YANG models which describe their NOS capabilities in their entirety, including both standards-based features and vendor proprietary features. These models will (but do not always) offer the guarantee that for the given vendor platform all available features can be automated in a structured way by an automation system. One advantage to using all native models can be to avoid the complexity of taking incomplete standards-based models and trying to create augmentations for different vendors by cherry picking pieces of the native models. On the other hand, the advantage of taking standards-based models and augmenting the missing pieces with native models can create synergies in network automation software between different platforms. + +Where working with cutting edge features the reality is that often the only approach practical is that of using a vendor-native model until such a time as open alternatives are updated. An additional area where standardization is problematic is the area of QoS. While there are efforts in both IETF and Openconfig to create standard models, it has proved very difficult (at least in IETF) to agree on certain aspects of this model. One of the challenges is the fact that vendor implementations vary considerably in the approaches to implementing QoS technologies, largely because this has been an area where vendors have deliberately sought to gain competitive advantage through their individual innovation efforts. + +##### 1.4.2.1.4 Network Slicing + +While not a focal point for this interaction of investigations, one area that merits further discussion is the topic of network slicing. There are many active drafts (many of which are currently Internet drafts) being worked on in the IETF that are looking to address interface standardization in the context of Network slicing. In most cases these are still in relatively early phases and expected to evolve of the next year. Some of the interesting drafts are listed here **NOT** as a recommendation but as a placeholder to be reviewed as part of a future version of this document. + +![O-RAN ALLIANCE logo](cc3b132d5e82e6f10c355d04ff55855e_img.jpg) + +O-RAN ALLIANCE logo + +The following draft describes a possible YANG interface for a YANG data model for the management of slice policies on slice policy capable nodes and controllers in IP/MPLS networks: +<https://datatracker.ietf.org/doc/html/draft-bestbar-teas-yang-slice-policy-00> + +There are several drafts that aim to provide a YANG model suitable for use on the northbound interface of the Network Slice Controller (NSC), the following seems to be one of the most advanced at this time: +<https://datatracker.ietf.org/doc/draft-ietf-teas-ietf-network-slice-nbi-yang/> + +#### 1.4.2.2 Control Plane Interfaces + +It is expected that many O-RAN networks will decide to adopt PCE based SDN controller which will interact directly with the control-plane of the network and provide greater visibility of the network topology and LSPs carrying IP or IPv6 traffic across the transport network. Additionally, many PCE based SDN controllers simplify the implementation of traffic engineering use cases like path diversity, BW calendaring, bin packing, LSP placement based on constraints such as inclusion or exclusion of certain links, max delay and many other use cases that can help to simplify operations, lower opex or improve the experience of the end customer. + +Typically, the PCE based controller interacts with the network using PCEP and BGP-LS, the capabilities offered by these protocols are often augmented through Netconf, Telemetry collection, config parsing and other mechanisms. + +This section attempts to define a set of minimum standards that are desired be supported by both the routers and the PCE SDN Controller. Table 13 list some of the IETF standards considered. + +| PCEP | | +|------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------| +| RFC/Draft | Description | +| RFC4655 | A Path Computation Element (PCE)-Based Architecture | +| RFC4657 | Path Computation Element (PCE) Communication Protocol Generic Requirements | +| RFC8408 | Conveying Path Setup Type in PCE Communication Protocol (PCEP) Messages | +| RFC8281 | Path Computation Element Communication Protocol (PCEP) Extensions for PCE-Initiated LSP Setup in a Stateful PCE Model | +| RFC8356 | Experimental Codepoint Allocation for the Path Computation Element Communication Protocol (PCEP) | +| RFC5440 | Path Computation Element (PCE) Communication Protocol (PCEP) | +| RFC8664 | Path Computation Element Communication Protocol (PCEP) Extensions for Segment Routing | +| RFC8051 | Applicability of a Stateful Path Computation Element (PCE) | +| RFC8231 | Path Computation Element Communication Protocol (PCEP) Extensions for Stateful PCE | +| draft-ietf-pce-segment-routing-policy-cp | PCEP extension to support Segment Routing Policy Candidate Paths | +| draft-ietf-pce-binding-label-sid | Carrying Binding Label/Segment-ID in PCE-based Networks. | +| RFC8623 | Stateful Path Computation Element (PCE) Protocol Extensions for Usage with Point-to-Multipoint TE Label Switched Paths (LSPs) | + +**Table 13 - PCEP RFCs and drafts** + +BGP-LS is widely used in transport SDN controllers to extract the IGP TED from the network via a BGP session. This allows the controller to build a topological view of the network and receive updates from the IGP when the network topology changes without being itself part of the IGP domain. This is generally the most widely deployed approach as it provides the ability to collate information from multiple different areas/ASes in a relatively straightforward manner. + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +Further to this in recent years BGP-LS has been extended to allow a simpler method of collection telemetry data from the network such as link latency, packet loss and available/residual bandwidth (see Table 14). + +| BGP-LS | | +|-----------|-------------------------------------------------------------------------------------------| +| RFC/Draft | Description | +| RFC7752 | North-Bound Distribution of Link-State and Traffic Engineering (TE) Information Using BGP | +| RFC8571 | BGP-LS Advertisement of IGP Traffic Engineering Performance Metric Extensions | + +Table 14 - BGP-LS and related drafts + +#### 1.4.2.3 Telemetry Interfaces + +When it comes to Performance Monitoring, both Openconfig and IETF models expose almost the same attributes. Openconfig models call them “counters”, while IETF groups them under a “statistics” container. Ingress and egress attributes are being defined, and every different attribute is of type “yang:counter64”, meaning an unsigned integer of 64 bites. Both models define attributes to measure how many octets were incoming or outgoing, how many of the ingress or egress packets were unicast, multicast, broadcast, discarded or with errors. Openconfig defines three extra attributes, as opposed to the IETF models: “in-pkts”, which counts the total number of packets which were incoming. The same value can be computed also in the IETF model, by adding the unicast, multicast, broadcast and error packets, and the model does not define this sum explicitly. The same is available for the egress, where the Openconfig model defines also the attribute “out-pkts” as the sum of the unicast, multicast, broadcast and error. Openconfig also defines explicitly the received packets which had an FCS error: “in-fcs-errors”. + +Since the PM attributes are defined in YANG, either gNMI Streaming Telemetry or polling via NETCONF get operations can be used to retrieve these metrics (see Figure 4 for a graphical explanation). As long as the model definition is YANG, the actual attributes defined in that model do not matter from a polling or streaming perspective. + +![Figure 4 - Telemetry models and protocols. The diagram illustrates two paths for retrieving telemetry data. On the left, the 'gNMI Stack' shows a stack of protocols: Data model (inner), gNMI, gRPC, HTTP/2, TLS, and TCP (outer). A 'protobuf' label points to the gNMI layer. A red diagonal line labeled 'Streaming Telemetry' connects the gNMI layer to the 'NETCONF Stack' on the right. The 'NETCONF Stack' shows a stack of protocols: Data model (inner), NETCONF, SSH/TLS, and TCP (outer). A 'xml/json' label points to the NETCONF layer. A green line labeled 'same YANG' connects the 'YANG Encoding (e.g. IETF_JSON)' box at the top to the 'YANG Encoding (e.g. XML/JSON)' box on the right. A bracket labeled 'NETCONF get operation' spans the NETCONF and SSH/TLS layers.](957eadcf27657f3e9a6ec7322967b8ab_img.jpg) + +Figure 4 - Telemetry models and protocols. The diagram illustrates two paths for retrieving telemetry data. On the left, the 'gNMI Stack' shows a stack of protocols: Data model (inner), gNMI, gRPC, HTTP/2, TLS, and TCP (outer). A 'protobuf' label points to the gNMI layer. A red diagonal line labeled 'Streaming Telemetry' connects the gNMI layer to the 'NETCONF Stack' on the right. The 'NETCONF Stack' shows a stack of protocols: Data model (inner), NETCONF, SSH/TLS, and TCP (outer). A 'xml/json' label points to the NETCONF layer. A green line labeled 'same YANG' connects the 'YANG Encoding (e.g. IETF\_JSON)' box at the top to the 'YANG Encoding (e.g. XML/JSON)' box on the right. A bracket labeled 'NETCONF get operation' spans the NETCONF and SSH/TLS layers. + +Figure 4 - Telemetry models and protocols + +![O-RAN ALLIANCE logo](99be9500d936730cac909cdccf03deeb_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient, followed by the text 'RAN' in blue and 'ALLIANCE' in smaller blue capital letters below it. + +O-RAN ALLIANCE logo + +### 1.4.3 Conclusion + +In general, there is much work that has already been done to standardize the interfaces used between the IP packet network controller and the IP nodes on the O-RAN network. When it comes to the configuration interfaces there would appear currently to be more comprehensive coverage with OpenConfig YANG models compared to those that are available in the IETF, this said neither option provides all features that we expect would be required for a fully automated O-RAN network. + +This considered, while it is recommended to adopt standard models as this will help with interoperability and API stability, it is acknowledged that proprietary extensions or use of native models may be required in cases where a single YANG model is not available that provides the full range of features required for a particular use case. Where working with cutting edge features the reality is that often the only approach practical is that of using a vendor-native model until such a time as open alternatives are updated. The advantage of taking standards-based models and augmenting the missing pieces with native models can create synergies in network automation software between different platforms. + +For the telemetry interfaces, there are no gaps in IETF or OpenConfig and both, gRPC or NETCONF can be used for retrieval. + +In the control plane there are mature IETF standards which are widely deployed and are desired to be leveraged as fully as possible. + +## 1.5 Grand master clock + +There is currently an active project in IEEE 1588 implementing YANG data models for the latest timing and synchronization standard IEEE 1588-2019 [22]. This project is scheduled to complete sometime in 2023/24. IEEE 1588-2019 defines a precision timing protocol to synchronize clocks in packet networks to a grandmaster clock. The YANG data models will enable customization of all IEEE 1588-2019 defined data types, message formats, required computations, internal states, the behavior of devices with respect to transmitting, receiving, and processing protocol communications. Draft YANG files can be viewed at [23]. + +# Annex B (informative): + +## 1 Network Slicing Use Case + +In this chapter we will look at the network slicing use case inside O-RAN. Ultimately, all the recommendations here will flow into the different chapters of the main document. But the goal right now is to define the functional elements and interfaces in one place as a use case before merging it back into the different chapters in a future version of this document. + +![Figure 5 - Functional architecture of the network slicing use case. The diagram shows a three-domain architecture: RAN Domain, Transport Network Domain, and Core Domain. At the top is 'E2E Service Orchestration'. Below it, 'RAN Domain Orchestration' (with O-RAN logo) and 'Core Domain Orchestration' are connected to 'Transport Network Domain Orchestration'. Inside the Transport domain, 'TN NSSMF' is connected via 'NS NBI' to 'Packet DC', 'Optical DC', 'uWave DC', and 'Access DC'. These are connected via 'NS SBI' to a 'TN NSSI Underlay' layer. This layer is connected to 'TN NSSI Overlay' layers in the RAN and Core domains. Below the overlays are 'NSSIs' and 'DCGWs'. At the bottom, 'TNE' (Transport Network Elements) are shown as a mesh of nodes.](ba8b318257c23bd6627997857fa0e82c_img.jpg) + +Figure 5 - Functional architecture of the network slicing use case. The diagram shows a three-domain architecture: RAN Domain, Transport Network Domain, and Core Domain. At the top is 'E2E Service Orchestration'. Below it, 'RAN Domain Orchestration' (with O-RAN logo) and 'Core Domain Orchestration' are connected to 'Transport Network Domain Orchestration'. Inside the Transport domain, 'TN NSSMF' is connected via 'NS NBI' to 'Packet DC', 'Optical DC', 'uWave DC', and 'Access DC'. These are connected via 'NS SBI' to a 'TN NSSI Underlay' layer. This layer is connected to 'TN NSSI Overlay' layers in the RAN and Core domains. Below the overlays are 'NSSIs' and 'DCGWs'. At the bottom, 'TNE' (Transport Network Elements) are shown as a mesh of nodes. + +**Figure 5 - Functional architecture of the network slicing use case** + +Figure 5 shows a WG9-centric functional view of the network slicing use case. The Network Slice Management Function is part of the end-to-end Orchestrator, orchestrating across Radio, Transport and Core domains. In the Transport Domain, which is the focus of this working group, there is a subserving Transport Network Slice function (TN NSSMF). The Transport Network Slice function breaks out the request into the different Transport Domains (e.g., Packet, Optical, Microwave, etc.). How this works will be a topic for future versions of this document. While the diagram shows stand-alone elements of SDN Controller functions for each domain, those individual controller functions could be physical entities or logical entities integrated into a carrier's SDN Controller Framework. Each of the domain controller functions then control the Transport Network Elements (TNE) creating end-to-end network slices. + +As part of the investigation the O-RAN WG9 team came up with three options for the controller architecture shown above. The first option uses the 3GPP models, the second follows very closely the IETF framework with different domain controllers per technology, the third option aligns more with the ONAP approach with a uniform network model. + +## 1.1 3GPP slicing model in application to network slicing in TN domain + +### 1.1.1 History / modeling concepts + +Since 3GPP Rel-10 3GPP SA5 has been working on the concept of Federated Network Models (FNM) based on the following principles (see clause 6.3 of 3GPP TR 32.828): + +- Not one authority (e.g. SDO) can be responsible for the development, maintenance and evolution of the whole model. Different organizations are responsible for the development, maintenance and evolution of their own domain specific model + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +- Operators may use the whole FMC model or part of the FMC model depending on their own business cases. +- Vendors can supply products using part of the FMC model depending on their own business cases. +- The model needs to hold thousands of inter-related modelled entities. Different versions of modelled entities can co-exist in the model. + +Essential FNM features include the ability to reference classes of "external" models, ability to import models designed elsewhere, independence of tool and platform, independence of solution technology and access protocol design. The key aspect of FNM approach is partitioning of the overall model into fragments with clear rules for inter-relationship of fragments. The advantages of FNM motivating its introduction documented in clause 6.3.2 of 32.828 are: + +- It removes the need to keep the evolution of various fragments in synchrony. For example, it is a valid model implementation where one fragment has evolved (requiring new solution) while other fragment remained unchanged (does not require new solution). +- Domain experts (e.g. LTE experts) can focus his design on its fragments and (can, if wanted to) be ignorant of contents of other fragments (e.g., mobile backhaul networks experts). + +In 3GPP Rel-11 a new set of NRM specifications (28.xxx series replacing 32.xxx series) has been published by 3GPP. It includes the "Federated Network Information Model (FNIM) Umbrella Information Model (UIM)" jointly published by 3GPP (as TS 28.620) and TMF (as FNIM). The structure of all 3GPP NRM follows the FNM approach: + +- at the root, there is a number of classes that form the UIM (see clause 4.1 of 3GPP TS 28.620). These classes are represented in UML and are implementation neutral views in that they only capture the semantics of the model from both a purpose neutral and purpose specific perspective. They do not include syntax or representation of the information in a system or on-the-wire between systems; and do not relate to the protocol used to create/delete/read/write/modify the NM information. +- Various SDOs and organizations are expected to use the UIM classes for definition of Domain/Technology-specific model classes. This procedure will maximize the probability of the domain/technology specific concrete classes (from various SDOs) being semantically consistent, a necessary characteristic for FMC NM purposes. +- 3GPP specifies Generic NRM IRP (3GPP TS 28.622) where it defines abstract classes aligned with UIM and other NRM IRPs such as E-UTRAN NRM IRP (3GPP TS 28.652), 5G NRM (3GPP TS 28.541) where it defines concrete classes. + +### 1.1.2 5G Slicing + +Starting from 3GPP Rel-15 a new management framework - Services Based Management Architecture (SBMA) (see 3GPP TS 28.533 for details) has been introduced. SBMA eliminates the need for normatively prescribing functional blocks as Management Functions (MnF) with mandatory sets of functional requirements and shifts the focus of standardization to definitions of Open APIs as Management Services (MnS). According to SBMA concepts, there is no restriction on what entities are allowed to consume MnS and what entities are mandated to produce the MnS - these details are left up to Operator's deployment preferences. In SBMA the management of slicing is not separated from the management of 5G System - Network Slicing is just a feature (among many others) supported by 5GS and by 5G management and orchestration. + +3GPP TS 28.533 clause 4.1 defines the fundamental building block of the SBMA as the MnS. A MnS is a set of offered capabilities for management and orchestration of network and services. The entity producing an MnS is called MnS producer. The entity consuming an MnS is called MnS consumer. An MnS provided by an MnS producer can be consumed by any entity with appropriate authorization and authentication. An MnS producer offers its services via a standardized service interface composed of individually specified MnS components. A MnS is specified using different independent components. A concrete MnS is composed of at least two of these components. Three different component types are defined, called MnS component type A (a group of management operations and/or notifications that is agnostic with regard to the entities managed), MnS component type B (management information represented by information models representing the managed entities) and MnS component type C (performance and fault information of the managed entity). + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +3GPP TS 28.541 (annex L) illustrates the role of the MnS component type B (3GPP NRM) in the slice fulfilment and assurance processes, and the relationship between GSMA GST, ServiceProfile and SliceProfile defined in clause 6 of TS 28.541. + +![Figure 6 (3GPP TS 28.541) Relation between GSMA GST, ServiceProfile and SliceProfile. The diagram shows the flow from NSC to Use Case, then to Service Requirements and Technical Requirements, which feed into the NEST. The NEST is linked to GST and Network Slice Instance Preparation. An SLA is shown as a translation from the NEST/GST area to the SLS ServiceProfile. The SLS ServiceProfile then branches into three translations: 5GC SliceProfile, NG-RAN SliceProfile, and TN requirements. These further translate into Configuration parameters for the 5GC domain, NG-RAN domain, and TN domain respectively.](26a388e0b8920827b16524108fb9e5ff_img.jpg) + +``` + +graph TD + NSC[NSC] --> UC[Use Case] + UC --> SR[Service Requirements] + UC --> TR[Technical Requirements] + SR --> NEST[NEST] + TR --> NEST + NEST --- GST[GSMA GST] + NEST --- NSIP[Network Slice Instance Preparation] + SLA[SLA] -- translation --> SPS[ServiceProfile] + SPS -- translation --> 5GSP[5GC SliceProfile] + SPS -- translation --> NGRANSP[NG-RAN SliceProfile] + SPS -- translation --> TNreq[TN requirements] + 5GSP -- translation --> CP5GC[Configuration parameters] + NGRANSP -- translation --> CPNGRAN[Configuration parameters] + CP5GC --> 5GCD[5GC domain] + CPNGRAN --> NGRAND[NG-RAN domain] + TNreq --> TND[TN domain] + +``` + +Figure 6 (3GPP TS 28.541) Relation between GSMA GST, ServiceProfile and SliceProfile. The diagram shows the flow from NSC to Use Case, then to Service Requirements and Technical Requirements, which feed into the NEST. The NEST is linked to GST and Network Slice Instance Preparation. An SLA is shown as a translation from the NEST/GST area to the SLS ServiceProfile. The SLS ServiceProfile then branches into three translations: 5GC SliceProfile, NG-RAN SliceProfile, and TN requirements. These further translate into Configuration parameters for the 5GC domain, NG-RAN domain, and TN domain respectively. + +**Figure 6 (3GPP TS 28.541) Relation between GSMA GST, ServiceProfile and SliceProfile** + +The scope of 3GPP (and 3GPP NRM) does not cover Transport Network (TN) management and orchestration, it does not define nor formally specify any of the TN entities. However, since TN is critical for successful deployment of 3GPP networks and 5G slicing, the interactions with TN are supported by NRM touch points where 3GPP NRM (MnS component B) entities have associations with entities from external (e.g. TN) models. Examples of such associations with entities of ETSI ISG NFV model (such as "NetworkService" and "VNF") are visible in the network slice NRM (see figure 6.2.1-1 in 3GPP TS 28.541). The interactions between 3GPP Management System and TN Management System in the context of network slicing management and orchestration are illustrated in clause 7.11 of 3GPP TS 28.801 and further elaborated throughout the 3GPP TS 28.531. + +The 3GPP Information model defines IP networking integration for Network Functions. The model had been progressively augmented to integrate slicing Use Cases. + +### 1.1.3 Slicing in 3GPP Release 15 + +Release 15 leverages the EP\_RP IOC defined in 3GPP TS 28.622/28.623 section 4.3.11. The EP\_RP IOC represents an end point of a link between two 3GPP network entities (e.g. EP\_F1U, EP\_F1C, EP\_N3...). TS 28.541 extends EP\_RP with the "localAddress" and "remoteAddress" attributes. + +- *localAddress* has two sub-attributes *vlanId* and *ipAddress* to manage the configuration of the underlying IP interface of the EP\_RP endpoint. +- *remoteAddress* is the address of the gateway (i.e. the route next-hop) associated with the underlying IP interface of the other EP\_RP endpoint. + +The same EP\_RP instantiation can be re-used to represent many-to-many connectivity as a collection of point-to-point links. For example, a CU-UP Network Function can connect with multiple UPF and conversely a single UPF can connect to multiple CU-UP Network Functions (see 2) + +#### 3GPP Network Slicing in Rel.15 - History + +![Figure 7: Specification view of Release 15. This diagram shows the evolution of 3GPP network slicing specifications. It starts with '28.620 Umbrella (Top_)' at the top, which points to '28.622/623 Generic'. From '28.622/623 Generic', a blue arrow points down to '28.541 15.8.2 F80 5G specific'. A grey arrow points right from '28.622/623 Generic' to 'Link 4.3.10', which then points to 'Topological link 4.3.10'. Another grey arrow points right from '28.622/623 Generic' to '28.632/633 Generic', which then points to 'Inventory Unit Hw 4.3.3.2'. From '28.541 15.8.2 F80 5G specific', two grey arrows point right to 'EP_NgU 4.3.11' and 'EP_N3 5.3.20'.](1206c204cf6657624fe364d384de0d70_img.jpg) + +Figure 7: Specification view of Release 15. This diagram shows the evolution of 3GPP network slicing specifications. It starts with '28.620 Umbrella (Top\_)' at the top, which points to '28.622/623 Generic'. From '28.622/623 Generic', a blue arrow points down to '28.541 15.8.2 F80 5G specific'. A grey arrow points right from '28.622/623 Generic' to 'Link 4.3.10', which then points to 'Topological link 4.3.10'. Another grey arrow points right from '28.622/623 Generic' to '28.632/633 Generic', which then points to 'Inventory Unit Hw 4.3.3.2'. From '28.541 15.8.2 F80 5G specific', two grey arrows point right to 'EP\_NgU 4.3.11' and 'EP\_N3 5.3.20'. + +Figure 7: Specification view of Release 15 + +#### 3GPP Network Slicing in Rel.15 – History + +There is NO Transport Network requirement for traffic segregation per slice +In this case Operator is not expecting any slicing on the TN domain +Slicing exists on 3GPP elements only + +Architecture view + +![Figure 8: Architecture view. many-to-many connectivity enforcement between CU-UP and UPF Network Functions. The diagram shows two main blocks: 'CU-UP1' (pink) on the left and 'UPF 1' (green) on the right. Above CU-UP1 is a box labeled 'EP_NgU 4.3.11'. Above UPF 1 is a box labeled 'EP_N3 5.3.20'. Inside CU-UP1, there are labels 'S-NSSAI 1', 'S-NSSAI 2', and '...', with arrows pointing to 'EP_NgU link to UPF1' and 'EP_NgU link to UPF n'. Inside UPF 1, there are labels 'S-NSSAI 1', 'S-NSSAI 2', and '...', with arrows pointing to 'EP_N3 link to CU-UP1' and 'EP_N3 link to CU-UP n'. A thick orange line connects the 'EP_NgU link to UPF1' box in CU-UP1 to the 'EP_N3 link to CU-UP1' box in UPF 1. Two thin lines also connect the 'EP_NgU 4.3.11' box to the 'EP_N3 link to CU-UP1' box.](e918cb208eab85fadbeffa50c6523f33_img.jpg) + +Figure 8: Architecture view. many-to-many connectivity enforcement between CU-UP and UPF Network Functions. The diagram shows two main blocks: 'CU-UP1' (pink) on the left and 'UPF 1' (green) on the right. Above CU-UP1 is a box labeled 'EP\_NgU 4.3.11'. Above UPF 1 is a box labeled 'EP\_N3 5.3.20'. Inside CU-UP1, there are labels 'S-NSSAI 1', 'S-NSSAI 2', and '...', with arrows pointing to 'EP\_NgU link to UPF1' and 'EP\_NgU link to UPF n'. Inside UPF 1, there are labels 'S-NSSAI 1', 'S-NSSAI 2', and '...', with arrows pointing to 'EP\_N3 link to CU-UP1' and 'EP\_N3 link to CU-UP n'. A thick orange line connects the 'EP\_NgU link to UPF1' box in CU-UP1 to the 'EP\_N3 link to CU-UP1' box in UPF 1. Two thin lines also connect the 'EP\_NgU 4.3.11' box to the 'EP\_N3 link to CU-UP1' box. + +Figure 8: Architecture view. many-to-many connectivity enforcement between CU-UP and UPF Network Functions + +### 1.1.4 Slicing in 3GPP Release 16 + +Release 16 introduces the EP\_Transport IOC in 3GPP TS 28.541 for Network slicing purposes. The EP\_Transport IOC permits to define additional logical IP Interfaces for each slice instance of the 3GPP User Plane. + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +![Figure 9: Example of the logic flow with 3GPP TS 28.541 parameters with Networking domain. The diagram shows the flow from GSMA NG.116 (Requirements, GST, NEST) to TS 28.541 (6.3.23 RANSliceSubnetProfile, 6.3.24 TopSliceSubnetProfile, 6.3.22 CNSliceSubnetProfile). These profiles lead to EP_NgU (4.3.11) or EP_Transport (6.3.17) endpoints. These endpoints connect to CU-UP N (S-NSSAI MTC) and the TN domain (TNE). The TN domain connects to the UPF.](9946e0efb16aa5076a38f9f1a4611c51_img.jpg) + +The diagram illustrates the logic flow for network configuration. It starts with GSMA NG.116 Requirements, which lead to GST and NEST. These feed into TS 28.541 parameters: 6.3.23 RANSliceSubnetProfile, 6.3.24 TopSliceSubnetProfile, and 6.3.22 CNSliceSubnetProfile. These profiles define endpoints: 4.3.11 EP\_NgU or 6.3.17 EP\_Transport. These endpoints connect to CU-UP N (S-NSSAI MTC) and the TN domain (TNE). The TN domain connects to the UPF. + +Figure 9: Example of the logic flow with 3GPP TS 28.541 parameters with Networking domain. The diagram shows the flow from GSMA NG.116 (Requirements, GST, NEST) to TS 28.541 (6.3.23 RANSliceSubnetProfile, 6.3.24 TopSliceSubnetProfile, 6.3.22 CNSliceSubnetProfile). These profiles lead to EP\_NgU (4.3.11) or EP\_Transport (6.3.17) endpoints. These endpoints connect to CU-UP N (S-NSSAI MTC) and the TN domain (TNE). The TN domain connects to the UPF. + +**Figure 9: Example of the logic flow with 3GPP TS 28.541 parameters with Networking domain** + +- A list of EP\_Transport IOC can be referenced by User Plane Endpoints (EP\_RP). In Release 16, the use of EP\_Transport is restricted to the Backhaul interface. In other words, only EP\_Ngu of the gnb CUUP and EP\_N3 of the 5GC UPF functions are extended with references to EP\_Transport. +- The EP\_Transport IOC has 4 attributes to handle the configuration of the Transport Network. + +#### - *ipAddress* + +This parameter permits to configure the IP Address of the interface associated with a transport slice. + +#### - *logicInterfaceId* + +**[R1]:** This parameter is a generic container for network data plane slice identifiers such as a vlan tag or an MPLS label. + +**[R2]:** \*Note As agreed within O-RAN WG5 and WG6, the basic slice delineation technology is IEEE 802.1Q VLAN tag. + +#### - *nextHopInfo* + +**[R3]:** This parameter is used to identify ingress transport node. Each node can be identified by any of combination of IP address of next-hop router, system name, port name, IP management address of transport nodes. + +#### - *qosProfile* + +This parameter references to a QoS Profile that is associated to the transport network interface. A QoS profile includes a set of parameters which are locally provisioned on both sides of a logical transport interface. + +![Figure 10: Specification view of Release 16 with per-slice EP_Transport example 1. The diagram shows a hierarchical structure starting from 28.620 Umbrella (Top_). It branches into 28.622/623 Generic, which connects to Link 4.3.10 and Topological link 4.3.10. Another branch goes to 28.632/633 Generic, which connects to Inventory Unit Hw 4.3.3.2. The main path goes to 28.541 5G specific, which then branches into EP_NqU 4.3.11 and EP_N3 5.3.20. These connect to a dashed box labeled 'NEW' containing EP_Transport 6.3.17 S-NSSAI MBB and EP_Transport 6.3.17 S-NSSAI URLLC for both EP_NqU and EP_N3.](0217c4f7707ef7a6346dc79b0f4997c4_img.jpg) + +## 3GPP Network Slicing in Rel.16 + +Figure 10: Specification view of Release 16 with per-slice EP\_Transport example 1. The diagram shows a hierarchical structure starting from 28.620 Umbrella (Top\_). It branches into 28.622/623 Generic, which connects to Link 4.3.10 and Topological link 4.3.10. Another branch goes to 28.632/633 Generic, which connects to Inventory Unit Hw 4.3.3.2. The main path goes to 28.541 5G specific, which then branches into EP\_NqU 4.3.11 and EP\_N3 5.3.20. These connect to a dashed box labeled 'NEW' containing EP\_Transport 6.3.17 S-NSSAI MBB and EP\_Transport 6.3.17 S-NSSAI URLLC for both EP\_NqU and EP\_N3. + +Figure 10: Specification view of Release 16 with per-slice EP\_Transport example 1 + +![Figure 11: Architectural view. Example 1 deployment options. This diagram shows the deployment of network slices across multiple User Plane Functions (UPFs) and Central User Plane (CU-UP) nodes. On the left, a large block represents the CU-UP1 node, which is divided into sections for S-NSSAI 1 and S-NSSAI 2. Each section contains an EP_NqU link to a specific UPF and an EP_Transport S-NSSAI block with CU-UP VLAN and IP. In the center, a CU-UP n node is shown with an EP_N3 5.3.20 link and an EP_Transport 6.3.17 block. On the right, there are three UPF blocks (UPF 1, UPF 2, and UPF 3). Each UPF block contains an EP_N3 link to a CU-UP node and an EP_Transport S-NSSAI block with UPF VLAN and IP. The diagram illustrates how different slices are mapped to specific UPFs and how they connect to the CU-UP nodes.](2b51f0054f46ff5aeeadb11c8bca83f8_img.jpg) + +Figure 11: Architectural view. Example 1 deployment options. This diagram shows the deployment of network slices across multiple User Plane Functions (UPFs) and Central User Plane (CU-UP) nodes. On the left, a large block represents the CU-UP1 node, which is divided into sections for S-NSSAI 1 and S-NSSAI 2. Each section contains an EP\_NqU link to a specific UPF and an EP\_Transport S-NSSAI block with CU-UP VLAN and IP. In the center, a CU-UP n node is shown with an EP\_N3 5.3.20 link and an EP\_Transport 6.3.17 block. On the right, there are three UPF blocks (UPF 1, UPF 2, and UPF 3). Each UPF block contains an EP\_N3 link to a CU-UP node and an EP\_Transport S-NSSAI block with UPF VLAN and IP. The diagram illustrates how different slices are mapped to specific UPFs and how they connect to the CU-UP nodes. + +Figure 11: Architectural view. Example 1 deployment options. + +![Figure 12: Specification view of Release 16 Example 2. The diagram shows a hierarchical network structure. At the top is '28.620 Umbrella (Top_)'. A blue arrow points down to '28.622/623 Generic'. From here, a grey arrow labeled 'Link 4.3.10' points to 'Topological link 4.3.10'. Another grey arrow points to '28.632/633 Generic', which then points to 'Inventory Unit Hw 4.3.3.2'. A blue arrow points down from '28.622/623 Generic' to '28.541 5G specific'. From '28.541 5G specific', three arrows branch out: one to 'EP_NgU 4.3.11', one to 'EP_N3 5.3.20 MBB', and one to 'EP_N3 5.3.20 URLLC'. From 'EP_NgU 4.3.11', two arrows branch out: one to 'EP_Transport 6.3.17 S-NSSAI MBB' and one to 'EP_Transport 6.3.17 S-NSSAI URLLC'.](4b178cc7ef16ba9e6ba23d15518947c2_img.jpg) + +### 3GPP Network Slicing in Rel.16 + +Figure 12: Specification view of Release 16 Example 2. The diagram shows a hierarchical network structure. At the top is '28.620 Umbrella (Top\_)'. A blue arrow points down to '28.622/623 Generic'. From here, a grey arrow labeled 'Link 4.3.10' points to 'Topological link 4.3.10'. Another grey arrow points to '28.632/633 Generic', which then points to 'Inventory Unit Hw 4.3.3.2'. A blue arrow points down from '28.622/623 Generic' to '28.541 5G specific'. From '28.541 5G specific', three arrows branch out: one to 'EP\_NgU 4.3.11', one to 'EP\_N3 5.3.20 MBB', and one to 'EP\_N3 5.3.20 URLLC'. From 'EP\_NgU 4.3.11', two arrows branch out: one to 'EP\_Transport 6.3.17 S-NSSAI MBB' and one to 'EP\_Transport 6.3.17 S-NSSAI URLLC'. + +Figure 12: Specification view of Release 16 Example 2, where extension of slices EP\_Transport is applied on NgU + +![Figure 13: Architectural view of Release 16 Example 2. The diagram shows the logical association between network elements. On the left, a large purple box represents the CU-UP1 entity, containing three S-NSSAI blocks: S-NSSAI 1 (top), S-NSSAI 1 (middle), and S-NSSAI 2 (bottom). Each block contains details about EP_NgU links to UPFs and EP_Transport S-NSSAI configurations. Above CU-UP1, a box shows 'EP_NgU 4.3.11 + EP_Transport 6.3.17' and another box shows 'EP_N3 5.3.20'. On the right, three green boxes represent UPF entities: 'UPF 1 S-NSSAI 1', 'UPF 2 S-NSSAI 1', and 'UPF 3 S-NSSAI 2'. Each UPF box contains details about EP_N3 links to CU-UP1 and CU-UP N. Orange arrows show logical associations from the EP_Transport S-NSSAI blocks in CU-UP1 to the corresponding EP_N3 links in the UPF entities. A blue arrow shows an association from the EP_NgU link in the bottom S-NSSAI 2 block to the EP_N3 link in the UPF 3 entity.](96e878324c81c75e6536e179097ff43b_img.jpg) + +### 3GPP Network Slicing in Rel. 16 + +Figure 13: Architectural view of Release 16 Example 2. The diagram shows the logical association between network elements. On the left, a large purple box represents the CU-UP1 entity, containing three S-NSSAI blocks: S-NSSAI 1 (top), S-NSSAI 1 (middle), and S-NSSAI 2 (bottom). Each block contains details about EP\_NgU links to UPFs and EP\_Transport S-NSSAI configurations. Above CU-UP1, a box shows 'EP\_NgU 4.3.11 + EP\_Transport 6.3.17' and another box shows 'EP\_N3 5.3.20'. On the right, three green boxes represent UPF entities: 'UPF 1 S-NSSAI 1', 'UPF 2 S-NSSAI 1', and 'UPF 3 S-NSSAI 2'. Each UPF box contains details about EP\_N3 links to CU-UP1 and CU-UP N. Orange arrows show logical associations from the EP\_Transport S-NSSAI blocks in CU-UP1 to the corresponding EP\_N3 links in the UPF entities. A blue arrow shows an association from the EP\_NgU link in the bottom S-NSSAI 2 block to the EP\_N3 link in the UPF 3 entity. + +Figure 13: Architectural view, corresponding to Example 2 (links represent logical association, not physical). + +### 1.1.5 Slicing in 3GPP Release 17 + +Release 17 extends the slicing data model introduced in Release 16 to the Midhaul Network. In other words, the 3GPP TS 28.541 slicing data model is augmented with EP\_Transport references for EP\_F1U on both gnbDU and gnb CU-UP Network Functions. + +![Diagram titled '3GPP Network Slicing in Rel.17' showing the hierarchy of network slicing data models. At the top is '28.620 Umbrella (Top_)'. A blue arrow points down to '28.622/623 Generic'. From '28.622/623 Generic', a grey arrow points right to 'Link 4.3.10', which then points to 'Topological link 4.3.10'. Another grey arrow points down from '28.622/623 Generic' to '28.632/633 Generic', which points right to 'Inventory Unit Hw 4.3.3.2'. A blue arrow points down from '28.622/623 Generic' to '28.541 5G specific'. From '28.541 5G specific', a dashed green box labeled 'NEW' encloses 'EP_F1U 4.3.13'. An arrow points from 'EP_F1U 4.3.13' to two stacked boxes: 'EP_Transport 6.3.17 S-NSSAI MBB' (brown) and 'EP_Transport 6.3.17 S-NSSAI URLLC' (blue). Below the dashed box, four more boxes are listed: 'EP_NgU 4.3.11 MBB' (brown), 'EP_NgU 4.3.11 URLLC' (blue), 'EP_N3 5.3.20 MBB' (brown), and 'EP_N3 5.3.20 URLLC' (blue). Arrows point from '28.541 5G specific' to each of these four boxes.](e96ae57f35e74c51f2f84c1fd18c1d52_img.jpg) + +Diagram titled '3GPP Network Slicing in Rel.17' showing the hierarchy of network slicing data models. At the top is '28.620 Umbrella (Top\_)'. A blue arrow points down to '28.622/623 Generic'. From '28.622/623 Generic', a grey arrow points right to 'Link 4.3.10', which then points to 'Topological link 4.3.10'. Another grey arrow points down from '28.622/623 Generic' to '28.632/633 Generic', which points right to 'Inventory Unit Hw 4.3.3.2'. A blue arrow points down from '28.622/623 Generic' to '28.541 5G specific'. From '28.541 5G specific', a dashed green box labeled 'NEW' encloses 'EP\_F1U 4.3.13'. An arrow points from 'EP\_F1U 4.3.13' to two stacked boxes: 'EP\_Transport 6.3.17 S-NSSAI MBB' (brown) and 'EP\_Transport 6.3.17 S-NSSAI URLLC' (blue). Below the dashed box, four more boxes are listed: 'EP\_NgU 4.3.11 MBB' (brown), 'EP\_NgU 4.3.11 URLLC' (blue), 'EP\_N3 5.3.20 MBB' (brown), and 'EP\_N3 5.3.20 URLLC' (blue). Arrows point from '28.541 5G specific' to each of these four boxes. + +**Figure 14: Extension of EP\_Transport support for F1U Endpoints in 3GPP Release 17** + +Network Slicing in Midhaul (F1\_U) and Backhaul (NgU) can be implemented in two ways: + +- Use dedicated network functions for each slice as depicted in Figure 15. +- Use shared network functions for slicing with different Transport Network planes as depicted in Figure 16. + +![Figure 15: Dedicated per slice CU-UP deployment. This architecture view shows a DU1 connected to multiple CU-UPs (CU-UP1, CU-UP2, etc.). Each CU-UP is associated with a specific S-NSSAI. The DU1 has links to each CU-UP via EP_F1U (4.3.13). Each CU-UP has links to the DU1 and to the network via EP_NgU (4.3.11). The CU-UPs are connected to UPFs (UPF1, UPF2, etc.) via EP_N3 (5.3.20). Each UPF is associated with a specific S-NSSAI and has links to the CU-UPs via EP_N3.](1f72f4ce76ecfe3083ef5acabf2945a8_img.jpg) + +Figure 15: Dedicated per slice CU-UP deployment. This architecture view shows a DU1 connected to multiple CU-UPs (CU-UP1, CU-UP2, etc.). Each CU-UP is associated with a specific S-NSSAI. The DU1 has links to each CU-UP via EP\_F1U (4.3.13). Each CU-UP has links to the DU1 and to the network via EP\_NgU (4.3.11). The CU-UPs are connected to UPFs (UPF1, UPF2, etc.) via EP\_N3 (5.3.20). Each UPF is associated with a specific S-NSSAI and has links to the CU-UPs via EP\_N3. + +Figure 15: Dedicated per slice CU-UP deployment + +![Figure 16: Shared CU-UP with transport slicing awareness. This architecture view shows a DU1 connected to a shared CU-UP1. The CU-UP1 is associated with multiple S-NSSAIs (S-NSSAI 1, S-NSSAI 2, etc.). The DU1 has links to the CU-UP1 via EP_F1U (4.3.13). The CU-UP1 has links to the DU1 and to the network via EP_NgU (4.3.11). The CU-UP1 is connected to UPFs (UPF1, UPF2, etc.) via EP_N3 (5.3.20). Each UPF is associated with a specific S-NSSAI and has links to the CU-UP1 via EP_N3. The CU-UP1 also has links to the UPFs via EP_Transport-S-NSSAI (CU-UP VLAN 1 + CU-UP IP 1, etc.).](667f04a4e986dccb364f5486178cffab_img.jpg) + +Figure 16: Shared CU-UP with transport slicing awareness. This architecture view shows a DU1 connected to a shared CU-UP1. The CU-UP1 is associated with multiple S-NSSAIs (S-NSSAI 1, S-NSSAI 2, etc.). The DU1 has links to the CU-UP1 via EP\_F1U (4.3.13). The CU-UP1 has links to the DU1 and to the network via EP\_NgU (4.3.11). The CU-UP1 is connected to UPFs (UPF1, UPF2, etc.) via EP\_N3 (5.3.20). Each UPF is associated with a specific S-NSSAI and has links to the CU-UP1 via EP\_N3. The CU-UP1 also has links to the UPFs via EP\_Transport-S-NSSAI (CU-UP VLAN 1 + CU-UP IP 1, etc.). + +Figure 16: Shared CU-UP with transport slicing awareness + +After this analysis and discussions within O-RAN WG9 the conclusion is that NRM 3GPP TS28.541 has not provide enough data to create valid Transport Network Slice. + +However, since some of the parameters required to create transport network slice may be extracted from NRM TS28.541 and some can be translated from SMO expectations, the following scope of work for WG9 and WG10 is proposed: + +- Collect missing parameters in NRM TS 28.541 for TN Slice creation +- Propose enhancements of NRM TS 28.541 to include OpenModelClass TNSliceSubnet to link EP\_Transport to TN and add options for linking 3GPP subsystems to TN subsystems +- File O-RAN liaison to SA5 in order to augment TS 28.541 with missing information and proposed items. +- Align with IETF TN Network Slice abstraction + +#### Observations + +The current data model has limited integration for IP networking capabilities. + +- No IP subnet mask in EP\_RP resource. This is required for the configuration of the gateway configuration. + - Note that the scope of this item is broader than user plane slicing since control plane interfaces also may require connectivity enforcement via the Transport Network. In the case + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +of control plane, EP\_RP is the only IP Networking data configuration in the 3GPP data model. + +- In this regard the current data model is inconsistent. The *IPv6Prefix* resource is defined +- No indirection capabilities in case of routed O-CLOUD infrastructure. The Transport Network can be attached via a different IP subnet than the IP subnet in which network function are deployed. This information may be provided to the Transport Network by 3GPP APIs. +- Next, more complex Transport Network integrations such as redundancy, routing protocols parameter may also be integrated. + +## 1.2 IETF Orchestrator and controller framework + +To support service automation, northbound abstraction of services and increasing interest in SDN, the IETF and other bodies, see multiple layers of orchestration and network control with different types of Yang models used in the end-to-end management of services in the transport network. The IETF has published various informational drafts that discuss different layering schemes and types of Yang models, include RFC8969 [24], RFC8199 [25], RFC8309 [26]. The basic premise in these drafts is there are different network management components communicating using different types of Yang models. Figure 17 and Figure 18 are taken from RFC8309 [26] and show environments where there is a three-layer architecture and a four-layer architecture, respectively. In a four-layer architecture the service orchestrator is exposed to the end-user customer and includes a customer service interface. + +![Figure 17 - Three-layer network management architecture [24]. The diagram shows a hierarchical structure with three layers. The top layer contains a single box labeled 'Orchestrator'. The middle layer contains three boxes labeled 'Controller'. The bottom layer contains four boxes labeled 'Network Element'. Vertical dashed lines indicate connections from the Orchestrator to each Controller, and from each Controller to its corresponding Network Element. There are also vertical dashed lines between the Network Elements.](c3a245228804f3795b39dd18e38d7c4f_img.jpg) + +``` + +graph TD + Orchestrator[Orchestrator] + Controller1[Controller] + Controller2[Controller] + Controller3[Controller] + NE1[Network Element] + NE2[Network Element] + NE3[Network Element] + NE4[Network Element] + + Orchestrator -.- Controller1 + Orchestrator -.- Controller2 + Orchestrator -.- Controller3 + Controller1 -.- NE1 + Controller2 -.- NE2 + Controller3 -.- NE3 + NE1 -.- NE2 + NE2 -.- NE3 + NE3 -.- NE4 + +``` + +Figure 17 - Three-layer network management architecture [24]. The diagram shows a hierarchical structure with three layers. The top layer contains a single box labeled 'Orchestrator'. The middle layer contains three boxes labeled 'Controller'. The bottom layer contains four boxes labeled 'Network Element'. Vertical dashed lines indicate connections from the Orchestrator to each Controller, and from each Controller to its corresponding Network Element. There are also vertical dashed lines between the Network Elements. + +**Figure 17 - Three-layer network management architecture [24]** + +![Figure 18 - Four-layer network management architecture [24]. The diagram illustrates a four-layer architecture. Layer 1 (top) shows the 'Customer Service Model' with a 'Service Orchestrator' and a 'Customer' connected by a bidirectional arrow labeled '(a)'. Layer 2 shows the 'Service Delivery Model' with a 'Network Orchestrator' and an 'Application BSS/OSS' connected by a bidirectional arrow labeled '(b)'. Layer 3 shows the 'Network Configuration Model' with two 'Network Orchestrator' blocks. Layer 4 (bottom) shows the 'Device Configuration Model' with four 'Controller' blocks. The bottom layer consists of five 'Network Element' blocks. Arrows indicate the flow of information and control between these layers.](608e4948278875b243d666c8a7c9be8b_img.jpg) + +Figure 18 - Four-layer network management architecture [24]. The diagram illustrates a four-layer architecture. Layer 1 (top) shows the 'Customer Service Model' with a 'Service Orchestrator' and a 'Customer' connected by a bidirectional arrow labeled '(a)'. Layer 2 shows the 'Service Delivery Model' with a 'Network Orchestrator' and an 'Application BSS/OSS' connected by a bidirectional arrow labeled '(b)'. Layer 3 shows the 'Network Configuration Model' with two 'Network Orchestrator' blocks. Layer 4 (bottom) shows the 'Device Configuration Model' with four 'Controller' blocks. The bottom layer consists of five 'Network Element' blocks. Arrows indicate the flow of information and control between these layers. + +**Figure 18 - Four-layer network management architecture [24]** + +Both environments support different types of Yang models including: + +- Service Models: An abstracted, non-technological view of a service. For example, an L2 or L3 VPN service as defined RFC 8466 [27] and 8299 [28]. +- Network Models: Topology and technology aware models of how the service will be realised on the network. For example, the L2NM and L3NM models for defining L2 and L3 VPN based on MP-BGP L2VPNs (draft-ietf-opsawg-l2nm-02) and L3VPNs (draft-ietf-opsawg-l3sm-l3nm-09). +- Device Models: Models used to configure specific functionality on the devices. + +Both environments differentiate the controller function from the orchestrator functions, with the controller providing the conversion of the network models into device configuration and the orchestrator responsible for conversion of an abstract model into a model that can be actioned by the controller. In the four-layer model there are two types of orchestrators with one associated with the service and the other associated with the network. + +The slice architecture proposed in O-RAN.WG9.XPSAAS-v03 outlines slicing solutions based on L2VPNs and L3VPNs utilising facilities within the transport network such as SR policies, Flex-algo and traffic + +![O-RAN ALLIANCE logo](100c8b2e5e489241b0a39f73a8896fd5_img.jpg) + +O-RAN ALLIANCE logo + +engineering. It also clear that a transport slice may be one or more VPNs at the transport layer. Various work is going on in the IETF TEAS group to come up with a transport slice NBI model which describes the customer transport slice requirements, at this time these are personal drafts so are not referenceable. There are also RFC based Yang models describing L2 and L3 service models and standards track drafts for a common VPN, L2 and L3NM models. In addition to the basic L2 / L3 service constructs there are other drafts such as draft-ietf-spring-sr-policy-yang-01, draft-ietf-teas-te-service-mapping-yang-07 which may have applications in mapping L2VPN and L3VPNs to underlay forwarding planes. + +At this time more work is required to understand how these different Yang models can work together to create an infrastructure suitable for slice orchestration. + +As part of this Network Slicing Use Case O-RAN also will issue recommendations on management interfaces between the different functions outlined above. The interface candidate between the end-to-end orchestrator and the Transport Network Slice Management function is currently a 3GPP definition, which will be more fleshed out in a future version of this document. The Interface between the Transport Network Slice Management function and the domain SDN-Controller functions still needs more definition in existing standards organizations and will also be fleshed out in more detail in future documents. The Interface candidates southbound of the Domain SDN Controller functions have already been described in the technology specific chapters in this document. + +## 1.3 Uniform transport network model + +The Service Management and Orchestration (SMO) framework inside the O-RAN Architecture is responsible for the Operations, Administration and Maintenance (OAM) functions. For facilitating these functions, the SMO is desired to communicate with the RAN network functions, as well as with the Transport Network network functions. This implies different YANG models for different technologies (e.g., Packet, Optical, Microwave, etc.), and even different YANG models from different SDOs for the same technology domain. It would be beneficial if all this complexity is not transferred through the Northbound Interface (NBI) to the other SMO components/applications (some examples might include a Transport Slice Controller – which handles network slicing use cases, or AI/ML applications doing, for example, predictive maintenance, or other possible Closed Loop end-to-end use cases, etc.). This is possible by adding an abstraction layer that exposes a uniform network model to other SMO components (NBI) and that communicate southbound with different technologies having different YANG models. This layer also needs a method to add some Enrichment information (be it from a database or some other means) that expresses, for example, links between domains, in cases where the network functions themselves are not able to express them. Figure 19 shows how such an abstraction layer could fit into the architecture of the SMO. + +![Figure 19: High level view of an Abstraction layer exposing a uniform Network Model. The diagram shows a central 'Abstraction Layer' block within the 'SMO OAM' section. This layer contains a 'Network (Model) Provider' (e.g., RESTCONF/YANG Server) and an 'Enrichment' database. A red dotted line labeled 'Domain specific augmentation' connects the provider to the enrichment database. The 'Abstraction Layer' sits on top of 'OAM Termination' (e.g., NETCONF/YANG Client). Above the SMO OAM block, a green arrow points up labeled 'To/From other SMO Components (including NSMF)' and a green arrow points down. A yellow callout box points to the 'Enrichment' database, stating: 'Topological Points and Links between domains (technological – CN, TN, AN; operators, ...) (e.g. SIP, E-NNI, ...)'. Below the abstraction layer, seven technology domains are shown with their respective logos and O-RAN logos: 5G Core, RAN, Small Cells & Wi-Fi, Packet, Optical, Microwave, and Fixed Access. Each domain has a green double-headed arrow connecting it to the OAM Termination layer.](1028071871ebe5af8e56b53bb1825a36_img.jpg) + +Figure 19: High level view of an Abstraction layer exposing a uniform Network Model. The diagram shows a central 'Abstraction Layer' block within the 'SMO OAM' section. This layer contains a 'Network (Model) Provider' (e.g., RESTCONF/YANG Server) and an 'Enrichment' database. A red dotted line labeled 'Domain specific augmentation' connects the provider to the enrichment database. The 'Abstraction Layer' sits on top of 'OAM Termination' (e.g., NETCONF/YANG Client). Above the SMO OAM block, a green arrow points up labeled 'To/From other SMO Components (including NSMF)' and a green arrow points down. A yellow callout box points to the 'Enrichment' database, stating: 'Topological Points and Links between domains (technological – CN, TN, AN; operators, ...) (e.g. SIP, E-NNI, ...)'. Below the abstraction layer, seven technology domains are shown with their respective logos and O-RAN logos: 5G Core, RAN, Small Cells & Wi-Fi, Packet, Optical, Microwave, and Fixed Access. Each domain has a green double-headed arrow connecting it to the OAM Termination layer. + +**Figure 19 - High level view of an Abstraction layer exposing a uniform Network Model** + +Utilizing a uniform network model brings the benefit of keeping the complexity as low as possible in the hierarchy, as well as avoiding duplicate work in the upper layers. It can be regarded as a service responsible for presenting a uniform network model to any other application or service interested, while translating or mapping the underlying device YANG models. An example of how such a service could fit into the controller architecture is depicted in Figure 20. + +In this way, the uniform network model could enable network slicing through a unified view of the underlying end-to-end network, as well as other use cases, such as AI/ML applications, Closed Loop use cases or Data Lakes that leverage a uniform end-to-end network view. + +![Figure 20 - High level controller architecture including uniform Network Model. The diagram shows a hierarchical architecture. At the top is the 'Network Slice Management Function NSMF'. Below it is a large blue rounded rectangle representing the 'Uniform network model'. Inside this rectangle, at the top, are 'AI/ML', 'Data lake', 'Transport Slice Controller', and 'Closed loop'. Below these is a red bar representing the 'Uniform network model'. Underneath the red bar are three boxes: 'Packet Domain Controllers', 'TDM Domain Controllers', and 'Optical Domain Controllers'. Below these are three boxes: 'Packet', 'TDM (OTN, FlexE)', and 'Optical'. Arrows indicate data flow and control. A dashed green box on the left points to the 'Uniform network model' and is labeled 'Other possible use-cases benefiting from a uniform network model'. A dashed red box on the right points to the 'Uniform network model' and is labeled 'Device models'. A bracket on the right groups the domain controllers and transport functionality. A red bar at the bottom is labeled 'Abstraction layer'.](fae7b157dd8a11380d3d2d396b5f23fe_img.jpg) + +Figure 20 - High level controller architecture including uniform Network Model. The diagram shows a hierarchical architecture. At the top is the 'Network Slice Management Function NSMF'. Below it is a large blue rounded rectangle representing the 'Uniform network model'. Inside this rectangle, at the top, are 'AI/ML', 'Data lake', 'Transport Slice Controller', and 'Closed loop'. Below these is a red bar representing the 'Uniform network model'. Underneath the red bar are three boxes: 'Packet Domain Controllers', 'TDM Domain Controllers', and 'Optical Domain Controllers'. Below these are three boxes: 'Packet', 'TDM (OTN, FlexE)', and 'Optical'. Arrows indicate data flow and control. A dashed green box on the left points to the 'Uniform network model' and is labeled 'Other possible use-cases benefiting from a uniform network model'. A dashed red box on the right points to the 'Uniform network model' and is labeled 'Device models'. A bracket on the right groups the domain controllers and transport functionality. A red bar at the bottom is labeled 'Abstraction layer'. + +**Figure 20 - High level controller architecture including uniform Network Model** + +The mapping or translation of the southbound models into the uniform network model, as well as the enrichment information for describing links between domains are key aspects of the proposed architecture. Concerning describing the enrichment or the topological information in a uniform way, there are two candidate topology models from two standards, namely the T-API topology model and the IETF-network-topology. The [T-API Topology](#) YANG model, defined by the Open Networking Foundation (ONF) has the following fulfillments: + +- It fulfils the requirements stated in this document, in Chapter 4 +- It provides the required abstractions according to requirements gathered by ONAP, based on operator and vendor input (details) +- It has an Apache 2.0 License (details [here](#)), accelerating the openness of the APIs + +With further investigation, open-source projects, namely TransportPCE and ONOS came into the picture which utilizes T-API topology in the NBI for the network view. T-API also supports multi-layer service and connection provisioning which makes T-API a good candidate. Nevertheless, T-API has been defined with the focus on optical network. The second candidate is the IETF-network-topology and the following section describes why it could be the recommended choice for the uniform network model. + +### 1.3.1 Multi-domain Support + +As the previous section acknowledges the features of T-API topology and existing proposals and implementations using T-API topology to control a heterogeneous optical network, the analysis of the possibilities of utilizing T-API topology for a uniform network view is performed. As a result, it is understood that T-API topology provides multi-layer topology representation of the L2-L0 network namely the DSR, OTU and Photonic Media layer. However, as the name suggests, T-API is a northbound standard for the transport domain with focus on the optical network. Although T-API do support multi-layer connection service creation, the question arises if T-API can also support multi-domain topological + +![O-RAN ALLIANCE logo](babf0d17d1b0140d9e86ea5a422acbac_img.jpg) + +O-RAN ALLIANCE logo + +representation and service creation beyond the optical domain. As of today, T-API supports the three interface profiles, namely, Layer 2 Carrier Ethernet, Layer 1 ODU Optical Transport Network and Layer 0 Photonic Media. If T-API can be extended to support non-optical interface profiles such as Microwave Radio Link remains unanswered today. + +The alternate topology model that has been analyzed is the IETF Network topology model as defined in RFC 8345. The approach here is to provide an abstract network topology data model as a generic base. This allows applications to operate on a topology of any network at a generic level, where the specifics of particular inventory/topology types are not required. + +![Figure 21 - IETF Network Topology diagram showing a hierarchical structure from Abstract Network Model down to specific L1, L2, L3, and Service models.](cd062c4631827801b39e776b6ff61f6e_img.jpg) + +``` +graph TD + ANM[Abstract Network Model] --> V1[V] + ANM --> V2[V] + V1 --> ATM[Abstract Topology Model] + V2 --> IM[Inventory Model(s)] + ATM --> V3[V] + ATM --> V4[V] + ATM --> V5[V] + ATM --> V6[V] + V3 --> L1[": L1 :"] + V4 --> L2[": L2 :"] + V5 --> L3[": L3 :"] + V6 --> S[": Service :"] + L1 --> T1[": Topology :"] + L2 --> T2[": Topology :"] + L3 --> T3[": Topology :"] + S --> T4[": Topology :"] + T1 --> M1[": Model :"] + T2 --> M2[": Model :"] + T3 --> M3[": Model :"] + T4 --> M4[": Model :"] +``` + +Figure 21 - IETF Network Topology diagram showing a hierarchical structure from Abstract Network Model down to specific L1, L2, L3, and Service models. + +**Figure 21 - IETF Network Topology** + +As seen in Figure 21, the abstract topology model can be used to define layer specific, service or use-case specific topology models. Concerning the uniform network model, such a generic model without the specifics of a particular inventory/topology types allows to present an aggregated and uniform network view without needing to provide any device related specifics. It could be also easier not only to describe multi-layer topologies but also multi-domain topologies w.r.t nodes and links. Furthermore, IETF provides different data models for different network layers such as RFC 8944 for Layer 2 and RFC 8346 for Layer 3 topologies. All these models are derived from the same ietf-network-topology which will technically make it easier for their augmentation into the same topology model when it comes to providing a uniform network view. + +Considering multi-domain support, unlike T-API, IETF indeed has various interface profiles beyond the optical domain. Few examples are RFC 8561 (Microwave Radio Link Yang Data Model) and RFC 9094 (YANG Data Model for Wavelength Switched Optical Networks (WSNs)). Additionally, IETF also supports the modelling schema according to Chapter 6. Hence, IETF network topology model could be used as the topology model taking into account a multi-domain, multi-layer network scenario. + +### 1.3.2 Abstraction Layer + +![Figure 22: High Level Architecture of the Abstraction Layer. The diagram shows a central 'Abstraction Layer' box containing several components. At the top is the 'Network /Model Provider' (blue box). Below it are the 'Network Domain Manager' (light blue box), 'Topology Manager' (yellow box), and 'Enrichment' (orange cylinder). The 'Network Domain Manager' is further divided into 'Translators' and 'Mappers'. A red bracket on the left labels the 'Network Domain Manager' as 'Domain-Specific'. Arrows show data flow: 'Device Information Model (Uniform view per Domain)' from the Network Domain Manager to the Network /Model Provider; 'Uniform Network View IETF-network-topology' from the Topology Manager to the Network /Model Provider; and bidirectional arrows between the Network Domain Manager and Topology Manager, and between the Topology Manager and Enrichment. External 'RESTCONF' connections are shown as double-headed arrows between the Network /Model Provider and the Abstraction Layer.](aa9efa3f68b336d9038be0697d28a549_img.jpg) + +Figure 22: High Level Architecture of the Abstraction Layer. The diagram shows a central 'Abstraction Layer' box containing several components. At the top is the 'Network /Model Provider' (blue box). Below it are the 'Network Domain Manager' (light blue box), 'Topology Manager' (yellow box), and 'Enrichment' (orange cylinder). The 'Network Domain Manager' is further divided into 'Translators' and 'Mappers'. A red bracket on the left labels the 'Network Domain Manager' as 'Domain-Specific'. Arrows show data flow: 'Device Information Model (Uniform view per Domain)' from the Network Domain Manager to the Network /Model Provider; 'Uniform Network View IETF-network-topology' from the Topology Manager to the Network /Model Provider; and bidirectional arrows between the Network Domain Manager and Topology Manager, and between the Topology Manager and Enrichment. External 'RESTCONF' connections are shown as double-headed arrows between the Network /Model Provider and the Abstraction Layer. + +**Figure 22: High Level Architecture of the Abstraction Layer** + +Figure 22 presents a high-level architecture of the Abstraction Layer, presenting the vital components that can achieve the uniform view of the network infrastructure. A brief explanation of these components and their functionalities follows as below: + +**Enrichment:** The enrichment component is the external information base that provides the topology information in terms of nodes and installed links between them. Sometimes devices support protocols such as LLDP and can provide the controller with information about its neighbours, using which an NBI application may be able to construct a topology. However, providing topology information is not a mandatory feature that needs to be supported by a device and even standards such as T-API expect such information to be externally provided to the controllers. This information is generally based on what is actually installed in the infrastructure and how all devices are connected to each other in reality. Therefore, such topological information can be provided by the operator who can obtain such information. Enrichment can further include multi-layer and logical topologies from various domains within the network. + +**Topology Manager:** This component will be responsible for creating a uniform view of the underlying topology by utilizing the topological knowledge from the Enrichment and translating all information into a uniform network model. As discussed above, this model could be created using the IETF network topology and can consist of multi-domain, multi-layer child or sub network topologies. + +**Network Domain Manager:** Considered to be domain-specific, this component handles the device and the technology specifics within a domain and models them into a uniform device information model. This component can be divided into two sub-components based on two chief functionalities. + +**Mapper:** The Topology Manager supports a logical or loose binding of the node information which means the node endpoint information advertised by the topology manager might not be the actual device/interface endpoints in the underlying infrastructure. A node in the uniform topology model could also represent multiple real devices or interfaces, grouped together by the operator to present a logical abstraction. However, a valid mapping between such logical representation and the actual nodes, devices have to exist in order to assist the controllers to configure, manage and monitor the corresponding devices in the underlying infrastructure. In the case of the uniform model view, this loose binding is handled by the Mapper. + +**Translator:** The handling of the translation of different domain-specific southbound device models to a uniform device information model is carried out by the Translator. As an example, if we consider a microwave domain with devices, few of which support the IETF Microwave Link Model and remaining the ONF microwave model, the translator needs to translate the device properties from these two models into the uniform model so as to present both kinds of devices to the NBI applications in a uniform way. + +**Network Model Provider:** The Network Model Provider functions as the API that can provide the network abstraction generated by the Topology Manager to the northbound applications. It also forwards any device information related requests to the Network Domain Manager where the Mapper identifies the devices and the Translator provides the corresponding specifics using the Network Model Provider. + +### 1.3.3 Uniform Device Information Model + +While the previous sections describe our analysis on the existing topology models namely T-API and IETF and our proposal of using IETF network topology to achieve the uniform topology model, this section elaborates the concept of the uniform device information model and the potential ways to achieve it. The uniform device information model can be acknowledged as a model capable of exposing the device specifics of the underlying infrastructure from each domain in a homogeneous way. The translation of device information to and from the diverse southbound device yang models is expected to be achieved by the Translator as in Section 9.3.4. In this section, we propose two possible approaches of realizing the Network Domain Manager-Translator and its functionalities. + +#### 1.3.3.1 Approach I – Defining a new Uniform Model + +![Diagram of Translator architecture example- Approach I. A central 'Translator' block is shown within a larger container. Below the Translator, there are two columns. The left column contains 'NewModel' and 'IETF' with a double-headed arrow between them. The right column contains 'NewModel' and 'ONF' with a double-headed arrow between them. Above the Translator, an arrow points upwards to the text 'A New Model'. Below the Translator, there are logos for 'IETF' and 'ONF' with arrows pointing towards the Translator block.](8b8dd66c264585aba05acf012e88eee4_img.jpg) + +Diagram of Translator architecture example- Approach I. A central 'Translator' block is shown within a larger container. Below the Translator, there are two columns. The left column contains 'NewModel' and 'IETF' with a double-headed arrow between them. The right column contains 'NewModel' and 'ONF' with a double-headed arrow between them. Above the Translator, an arrow points upwards to the text 'A New Model'. Below the Translator, there are logos for 'IETF' and 'ONF' with arrows pointing towards the Translator block. + +Figure 23 - Translator architecture example- Approach I + +Consider the Microwave domain as an example comprised of devices following either of the two models- IETF Microwave Link or the ONF Microwave Model. With this approach, the aim is to translate both the IETF Microwave Link and the ONF Microwave model to a new uniform model. It will be this new model that will be exposed to the NBI applications such as the slice controller while the translator performs the adaptation of the IETF and the ONF models to this uniform model and vice versa. However, this approach requires to define this new model as no such uniform model exists for any domain today. Also, the definition of this model must include sufficient parameters with minimal gaps and must be also complete enough to suffice the translation to and from both IETF and ONF models as in the case of this example. Additionally, as the translator has to perform the translation of both IETF and ONF models to and from this new model, the Translator needs to be equipped with two independent translation functionalities for each standard in this example. + +#### 1.3.3.2 Approach II – Defining a Uniform Model with domain specific augmentations + +Let's consider the same scenario of the microwave domain again consisting of both IETF and ONF compliant devices. However, as shown in Fig. 24, instead of defining a new uniform model, this approach aligns with the objective of reusing the existing models. + +![Figure 24 - Translator architecture example- Approach II. The diagram shows a 'Translator' block at the top, with 'ONF' on the left and 'IETF' on the right. Below 'ONF' is the 'Air Interface' section, containing 'ONF' and 'IETF' with a double-headed arrow between them. Below 'IETF' is the 'Ethernet' section, containing 'IETF' and 'ONF' with a double-headed arrow between them. To the right of these sections is a vertical bar labeled 'Technology Specific Augmentations' at the top and 'Microwave Domain' at the bottom. Above the 'Translator' block is the label 'Domain Specific Augmentations' with an upward arrow. Below the 'Translator' block are the IETF and ONF logos, with arrows pointing up towards the 'Translator' block.](a828c396b6d8703449ba4b53cbba3ebe_img.jpg) + +Figure 24 - Translator architecture example- Approach II. The diagram shows a 'Translator' block at the top, with 'ONF' on the left and 'IETF' on the right. Below 'ONF' is the 'Air Interface' section, containing 'ONF' and 'IETF' with a double-headed arrow between them. Below 'IETF' is the 'Ethernet' section, containing 'IETF' and 'ONF' with a double-headed arrow between them. To the right of these sections is a vertical bar labeled 'Technology Specific Augmentations' at the top and 'Microwave Domain' at the bottom. Above the 'Translator' block is the label 'Domain Specific Augmentations' with an upward arrow. Below the 'Translator' block are the IETF and ONF logos, with arrows pointing up towards the 'Translator' block. + +Figure 24 - Translator architecture example- Approach II + +Both approaches require a thorough study and comparison of device models from different standards within a given domain. However, this approach aims to utilize the understanding of the existing models and their gaps to create a model composed of domain and technology specific augmentations. In this microwave domain example, according to Fig. 24, it is assumed that the definition of the microwave or the air interface in the ONF Microwave Model is more absolute than the IETF counterpart, therefore, the uniform model would consider the augmentation of the ONF air-interface pac to describe the microwave interfaces of the underlying devices. On the other hand, it is assumed that with respect to Ethernet, the definitions provided by IETF are thorough and therefore, would be augmented to the uniform model. As a result, the uniform model is generated with augmentations from different standards based on their thoroughness and sufficiency. Concerning the translator in this example, a translation would be required to and from ONF to IETF for the air interface and similarly to and from IETF to ONF for the Ethernet interface. However, this eliminates the necessity of two independent and complete translations between IETF, ONF and the uniform model unlike approach I. As part of future work, the evaluation and comparison of models from different standards in different domains would be executed. An analysis of the gaps and the feasibility of such technology specific augmentations will be presented. + +### 1.3.4 Conclusion + +This chapter elaborates the concept of the uniform network model and the benefits it brings in moderating the complexity of network control and management when it comes to creating connectivity services or network slices across domains following different standards and device models. As a starting point, this chapter includes a brief overview of our survey on the topological model of two standards namely T-API and IETF and possibilities of utilizing them for the uniform network view. As a result, it has been highlighted that T-API and its supported interface profiles have a strong hold on optical domain. IETF on the other hand, supports diverse interface profiles from different domains, hence, can be considered as a better choice. A high-level architecture of the Abstraction Layer is introduced in this phase with a brief explanation of the possible components in this layer. As part of this concept, two approaches of constructing the unified device information model have been proposed. In the next phases, an examination of different models from different domains will be performed in order to understand the existing gaps and also the feasibility of reusing the existing models when it comes to constructing the uniform network model. + +# Annex C (informative) + +## 1 Management and network models for correlation of Network Slicing in RAN and Core subsystems with Transport Network domain + +Definition of the scope of Management Interfaces phase 5: + +1. WG9 Transport Management Interfaces spec and WG9 Transport Network slicing architecture spec are developed based on the contributions and spec readiness of other WGs and WIs. +2. F1\_U and NgU interface slicing capabilities are based on the readiness and contribution progress of WG5 and WG6. This at the moment of Nov 2022 includes: + 1. Network Slice Instantiation and separation in per NSSAI on RAN and Core may be done in many-to-many fashion as described in RBBN.AO-2022.02.22-WG9-CR-0001-XTRP-MGT.0-v.03.50-v03 + 2. Network Slice isolation on RAN and Core may be done in VLAN+IPv4/v6 or single VLAN + [per-slice IPv6] fashion. + 3. Single set of 3GPP IOCs parameters defined on **Dynamic5QISet**, **Configurable5QISet** and **FiveQIDscpMapping** on O-RAN subsystem are expected for all slices. +3. Shared O-RU WI demands for slicing and separation are not included in phase 5 or 6. +4. Network Sharing use cases are not included in phase 5 or 6 of this document. + +![Figure 25: Network slicing architecture diagram showing three use cases: Fronthaul Network sharing, Midhaul Network Slicing, and BackHaul Network Slicing. The diagram illustrates the flow of traffic through various network elements (O-RU, O-DU, O-CU-UP, UPF) and the associated management and protection sets. A red box highlights the 'Scope for November train' which includes the Midhaul and BackHaul slicing use cases.](908c1e5bc4d8fd2323b9c639234682cc_img.jpg) + +The diagram illustrates the network slicing architecture across three domains: Fronthaul, Midhaul, and BackHaul. It shows the flow of traffic through various network elements (O-RU, O-DU, O-CU-UP, UPF) and the associated management and protection sets. A red box highlights the 'Scope for November train' which includes the Midhaul and BackHaul slicing use cases. + +- Fronthaul Network sharing use case:** Includes 'Connectivity options set 1' and 'Protection / topology set 1'. It shows a Shared O-RU (PLMN ID 100, PLMN ID 200) connected to a TN (Transport Network) via VLANs. +- Midhaul Network Slicing use case:** Includes 'Connectivity options set 2' and 'Protection / topology set 2'. It shows an O-DU (PLMN ID 100, S-NSSAI eMBB) connected to a TN via VLANs. +- BackHaul Network Slicing use case:** Includes 'Connectivity options set 2' and 'Protection / topology set 2'. It shows an O-CU-UP (S-NSSAI eMBB) connected to a TN via VLANs. +- UPF 1 (S-NSSAI eMBB):** Connected to the BackHaul TN via VLANs. +- Logical associations / architecture options:** Set 1 is associated with the Fronthaul use case, Set 2 with the Midhaul and BackHaul slicing use cases, and Set 3 with the Midhaul and BackHaul sharing use cases. + +Figure 25: Network slicing architecture diagram showing three use cases: Fronthaul Network sharing, Midhaul Network Slicing, and BackHaul Network Slicing. The diagram illustrates the flow of traffic through various network elements (O-RU, O-DU, O-CU-UP, UPF) and the associated management and protection sets. A red box highlights the 'Scope for November train' which includes the Midhaul and BackHaul slicing use cases. + +Figure 25 + +### Problem statement. + +Due to the fact that in current version Rel. 17 3GPP IM/DM TS 28.541 is not fully defined per-slice subnet transport link between the RAN subsystem and Transport Network domain, provisioning of the slice in the transport and automation is a complicated task to perform. Interfaces F1 is not included in EP\_Transport. and other interfaces. + +![O-RAN ALLIANCE logo](100c8b2e5e489241b0a39f73a8896fd5_img.jpg) + +O-RAN ALLIANCE logo + +In order to define the model of the network slice in transport network in more formal way the next steps, highlighted in Phase 4 of the current document were taken and sent a liaison # S-2022003 “Transport Network Slicing Enhancement IM/DM TS28.541” to 3GPP SA5, capturing identified gaps and inputs from the WG9. + +The resulting S5-225603 change was submitted to SA5 group, captured the confederated data model approach with a link to external object class model in IETF framework, namely we are targeting draft-ietf-teas-ietf-network-slice-nbi-yang-02 with model definition draft-ietf-teas-ietf-network-slices-14. + +![Figure 26: A conceptual diagram showing the relationships between various network slice components. At the top is 'EP_Transport'. Below it are 'EP_Application (F1U, N3, NgU)' and 'Network-slice-nbi-yang + draft-ietf-teas-ietf-network-slices-14'. 'EP_Application' and the IETF model both point to 'EP_Transport'. The IETF model also points to 'Constructs' and 'Constraints restrictions'. 'Constructs' (with the red text 'What should I connect?') and 'Constraints restrictions' (with the red text 'AKA Service Requirements' and 'How should I connect?') are interconnected. 'Constructs' points to 'SDP', 'L2/I3sm', and 'Topo'. 'Constraints restrictions' points to 'TE' and 'SLO/QoS'. 'Topo', 'TE', and 'SLO/QoS' all point to 'FlexAlgo' at the bottom.](bf6d824dae7832b6e3b17f3d53b31277_img.jpg) + +Figure 26: A conceptual diagram showing the relationships between various network slice components. At the top is 'EP\_Transport'. Below it are 'EP\_Application (F1U, N3, NgU)' and 'Network-slice-nbi-yang + draft-ietf-teas-ietf-network-slices-14'. 'EP\_Application' and the IETF model both point to 'EP\_Transport'. The IETF model also points to 'Constructs' and 'Constraints restrictions'. 'Constructs' (with the red text 'What should I connect?') and 'Constraints restrictions' (with the red text 'AKA Service Requirements' and 'How should I connect?') are interconnected. 'Constructs' points to 'SDP', 'L2/I3sm', and 'Topo'. 'Constraints restrictions' points to 'TE' and 'SLO/QoS'. 'Topo', 'TE', and 'SLO/QoS' all point to 'FlexAlgo' at the bottom. + +Figure 26 + +The Rel. 17 3GPP IM/DM TS 28.541 object class relationships as proposed by S5-225603, includes the link to such model outside of 3GPP: + +![Figure 27: A UML class diagram showing the relationship between EP_Transport and its components. EP_Transport is an «InformationObjectClass». It has two associations with «ProxyClass» objects: EP_Application and NextHopInfo. Both associations are marked with '*' at both ends. A callout box for EP_Application states: 'This represents EP_N3 or EP_NgU or EP_F1U'. A callout box for NextHopInfo states: 'This represents object classes defined by TN domain related external SDOs'.](3411da76aef221d23d9e0f4bc753b3d9_img.jpg) + +Figure 27: A UML class diagram showing the relationship between EP\_Transport and its components. EP\_Transport is an «InformationObjectClass». It has two associations with «ProxyClass» objects: EP\_Application and NextHopInfo. Both associations are marked with '\*' at both ends. A callout box for EP\_Application states: 'This represents EP\_N3 or EP\_NgU or EP\_F1U'. A callout box for NextHopInfo states: 'This represents object classes defined by TN domain related external SDOs'. + +Figure 27 + +## 1.1 IETF slice Framework design. + +IETF is working on the definition of what is called IETF Network Slices, that essentially describe how to request and realized network slices. The IETF Network Slice Controller is intended to offer a technology-agnostic North Bound Interface (NBI) for receiving the transport slice requests from consumers of transport capabilities, as in this case. The advantage of this is the fact of facilitating the integration of different technologies to serve TN slice requests following a common format. + +![Figure 28 - IETF Network Slice Controller architecture diagram](49c17b31789f6c3ff88eb981b1499ae0_img.jpg) + +``` + +graph TD + A[Customer higher level operation system +(e.g E2E network slice orchestrator, +customer network management system)] + B[IETF Network Slice Controller (NSC)] + C[Network Controllers] + A -- "A +IETF Network Slice Service Interface +V" --> B + B -- "A +Network Configuration Interface +V" --> C + +``` + +The diagram illustrates the IETF Network Slice Controller architecture. It consists of three main components arranged vertically: the Customer higher level operation system (e.g., E2E network slice orchestrator, customer network management system), the IETF Network Slice Controller (NSC), and the Network Controllers. The Customer system connects to the NSC via the IETF Network Slice Service Interface (A to V). The NSC connects to the Network Controllers via the Network Configuration Interface (A to V). + +Figure 28 - IETF Network Slice Controller architecture diagram + +**Figure 28 - IETF Network Slice Controller** + +The IETF Network Slice Service Interface definition, as North Bound Interface (NBI) of the Network Slice Controller, is a work in progress documented in [draft-ietf-teas-ietf-network-slice-nbi-yang-02]. The current approach is to create a model which allows the requests of connectivity constructs among Service Demarcation Points (SDPs) defined by the slice customer (e.g., the 3GPP Management System). Those connectivity constructs have a number of associated SLOs which will define the service constraints to be satisfied at the time of realizing the transport slice. Several connectivity constructs, each of them with different connectivity patterns, can be defined via the NBI. + +![Figure 29 - Connectivity constructs patterns on the NBI](75e9903d54dff18c5eccec64e77fc196_img.jpg) + +The diagram shows the connectivity constructs patterns on the NBI. A large grey arrow at the top indicates that the IETF Network Slice Service (NS1) consists of four Connectivity matrices with 4 different SLAs: Blue, Red, and Green. Below this, four connectivity constructs are shown, each with a specific type and key: + +- Blue:** Type Any-to-any, connectivity-matrix-id = Blue, Key=Blue. It connects SDP<sub>1</sub> and SDP<sub>2</sub> to SDP<sub>6</sub>. +- Orange:** Type P2P, connectivity-matrix-id = Orange, Key= Orange. It connects SDP<sub>3</sub> to SDP<sub>7</sub>. +- Red:** Type P2P, connectivity-matrix-id = Red, Key=Red. It connects SDP<sub>3</sub> to SDP<sub>7</sub>. +- Green:** Type P2MP, connectivity-matrix-id = Green, Key=Green. It connects SDP<sub>5</sub> to SDP<sub>9</sub> and SDP<sub>10</sub>. + +Figure 29 - Connectivity constructs patterns on the NBI + +**Figure 29 - Connectivity constructs patterns on the NBI** + +Each of the connectivity constructs in Figure 29 (i.e., blue, orange, red and green) can have different SLOs associated, as input to provide differentiated behaviors on the transport side. + +In practical terms the model, the way of defining the connectivity construct which are part of a slice (on current NBI version) is as follows: + +``` + ++--rw connectivity-construct* [cc-id] +| +--rw cc-id +| | +| | uint32 +| +--rw (connectivity-construct-type)? +| | +--:(p2p) +| | | +--rw p2p-sender-sdp? +| | | | -> ../../../../sdps/sdp/sdp-id +| | | +--rw p2p-receiver-sdp? +| | | | -> ../../../../sdps/sdp/sdp-id +| | +--:(p2mp) +| | | +--rw p2mp-sender-sdp? +| | | | -> ../../../../sdps/sdp/sdp-id +| | | +--rw p2mp-receiver-sdp* +| | | | -> ../../../../sdps/sdp/sdp-id +| | +--:(a2a) +| | | +--rw a2a-sdp* [sdp-id] +| | | | +--rw sdp-id +| | | | leafref +| | | +--rw (slo-sle-policy)? +| | | ... +| +--rw (slo-sle-policy)? +| ... + +``` + +While the SLO policy can be explicitly determined in the model + +``` + ++--rw (slo-sle-policy)? +| +--:(standard) +| | +--rw slo-sle-template? +| | leafref +| +--:(custom) +| +--rw service-slo-sle-policy +| +--rw policy-description? +| string +| +--rw metric-bounds +| | +--rw metric-bound* [metric-type] +| | +--rw metric-type +| | identityref +| | +--rw metric-unit +| | string +| | +--rw value-description? +| | string +| | +--rw bound? +| | uint64 +| +--rw security* +| identityref +| +--rw isolation? +| identityref +| +--rw max-occupancy-level? +| uint8 +| +--rw mtu? +| uint16 +| +--rw steering-constraints +| +--rw path-constraints +| +--rw service-function + +``` + +With the progress of the activity in IETF, it is yet necessary to define the mapping of slice parameters between 3GPP and IETF. At the time of provisioning a 3GPP slice, it is necessary to bind two different kind of endpoints, as depicted in Figure 30: + +- Mapping of EP\_Transport (as defined by [TS28.541]) to the endpoint at the CE side of the IETF network slice. This is necessary because the IETF Network Slice Controller (NSC) will receive as input for the IETF network slice service the set of endpoints at CE side to be interconnected +- Mapping of the endpoints at both CE and PE side. The endpoint at PE side must be elicited by some means by the NSC, in order to establish and set up the connectivity construct intended for the customer slice request, according to the SLOs and SLEs received from the higher-level system. + +![Figure 30 - Mapping process diagram. The diagram illustrates the mapping between 3GPP and IETF network slice concerns. At the top, under '3GPP concern', there are two light blue parallelogram planes, each containing a dark blue circle labeled 'EP_Transport'. A dashed double-headed arrow connects these two circles. Below them, under 'IETF concern', there are two light blue parallelogram planes, each containing a light blue circle labeled 'CE_left' and 'CE_right' respectively. A central dark blue cloud-like shape represents the network, with 'PE_left' and 'PE_right' labels on its left and right sides. Dashed arrows show the mapping: from 'EP_Transport' in the 3GPP layer down to 'CE_left' and 'CE_right' in the IETF layer, and from 'PE_left' and 'PE_right' in the IETF layer up to the 'EP_Transport' circles. A dashed double-headed arrow also connects 'CE_left' and 'CE_right'.](f5474745e5c176ac0be4a6154e1fc22d_img.jpg) + +Figure 30 - Mapping process diagram. The diagram illustrates the mapping between 3GPP and IETF network slice concerns. At the top, under '3GPP concern', there are two light blue parallelogram planes, each containing a dark blue circle labeled 'EP\_Transport'. A dashed double-headed arrow connects these two circles. Below them, under 'IETF concern', there are two light blue parallelogram planes, each containing a light blue circle labeled 'CE\_left' and 'CE\_right' respectively. A central dark blue cloud-like shape represents the network, with 'PE\_left' and 'PE\_right' labels on its left and right sides. Dashed arrows show the mapping: from 'EP\_Transport' in the 3GPP layer down to 'CE\_left' and 'CE\_right' in the IETF layer, and from 'PE\_left' and 'PE\_right' in the IETF layer up to the 'EP\_Transport' circles. A dashed double-headed arrow also connects 'CE\_left' and 'CE\_right'. + +**Figure 30 - Mapping process** + +![O-RAN ALLIANCE logo](100c8b2e5e489241b0a39f73a8896fd5_img.jpg) + +O-RAN ALLIANCE logo + +As a result of the recent extensive work on the correlation and mapping between 3GPP IM/DM and TN (IETF) IM in the context of network slicing management and orchestration is captured in the “IETF Network Slice Application in 3GPP 5G End-to-End Network Slice” draft (<https://datatracker.ietf.org/doc/draft-ietf-teas-5g-network-slice-application/>). + +Version 00 (Version 01) of it is covering 3 example options of the mapping 3GPP NRM and IETF models: + +- 1 - NBI-Yang CE-opt. Like draft Example-7: SDP at CE, L3 any-to-any Slice Service with Network abstraction +- 2 - NBI-Yang PE-opt +- 3 - NBI-Yang PE-opt and ac with ac-draft + +![Diagram illustrating three mapping options (1, 2, 3) for SDP and AC components across Customer and Provider Edges.](68a7ca8ee3052c1504604df432afe74e_img.jpg) + +The diagram illustrates three mapping options (1, 2, 3) for SDP and AC components across Customer and Provider Edges. The components are represented as boxes with dashed borders, and the connections are indicated by dashed lines. + +- Option 1:** SDP is located at the Customer Edge (CE) element. It is connected to the AC (Access Control) element at the Provider Edge (PE) element. +- Option 2:** SDP is located at the PE element. It is connected to the AC element at the PE element. +- Option 3:** SDP is located at the PE element. It is connected to the AC element at the PE element, and the AC element is also connected to the SDP element at the CE element. + +The diagram shows the following components and connections: + +- Customer Edge 1:** Contains SDP (Option 1) and AC (Option 3). +- Provider Edge 1:** Contains FE1 (Function Element 1) and SDP (Option 2). +- Provider Edge 2:** Contains FE2 (Function Element 2) and SDP (Option 2). +- Customer Edge 2:** Contains SDP (Option 1) and AC (Option 3). + +Connections are shown between SDP and AC elements across the edges, and between FE1 and FE2 elements. + +Diagram illustrating three mapping options (1, 2, 3) for SDP and AC components across Customer and Provider Edges. + +The rationale for this work is that comprehensive communication services utilize a blend of components defined by the 3GPP and non-3GPP entities like Data Centre Networks (DCN) and Transport Networks (TN). + +To adhere to service provisioning procedures and maintain service performance, a degree of alignment is required between the 3GPP management system and the management systems of non-3GPP components such as the Management and Orchestration (MANO) system and the Internet Engineering Task Force (IETF) defined transport system. + +The coordination process entails two primary actions: + +- Procurement of capabilities specific to non-3GPP components. +- Articulation of operational requirements, including slice-specific prerequisites pertaining to non-3GPP elements. + +This draft is describing options when SDP is located on the CE (3GPP) element, TN PE element and utilizing the approach for Data Model of the Network Slice, and also extending "attachment-circuits" section of the model by referring to the IDs of AC's Data Models from the AC draft [draft-boro-opsawg-teas-attachment-circuit/](https://datatracker.ietf.org/doc/draft-boro-opsawg-teas-attachment-circuit/) + +3GPP NRM Rel 18 TS-28.541 Clause 6.3.35 LogicalInterfaceInfo represents 3GPP IOC with TN-related parameters of 3GPP subsystem interpreted in NRM to DM mapping example as CE network configuration of current model and may be referenced as a 'peer-sap-id' remote endpoint of the attachment circuit with parameters as 'nf-termination-ip' and 'nf-termination-vlan', and parameters related to the physical connection and associated with Bearer Service "ietf-ac-svc:attachment-circuits:ietf-bearer-svc" + +3GPP NRM TS-28.541 6.3 ConnectionPointInfo represents 3GPP IOC with link to external data model in IETF draft-boro-opsawg-teas-attachment-circuit in order to link the corresponding 3GPP subsystem Transport Network-related slice Meeting Point (Clause 6.3.18 EP\_Transport) to IETF Network Slice attachment circuit. + +![O-RAN ALLIANCE logo](100c8b2e5e489241b0a39f73a8896fd5_img.jpg) + +O-RAN ALLIANCE logo + +As the I-D.ietf-teas-ietf-network-slices (<https://datatracker.ietf.org/doc/draft-ietf-teas-ietf-network-slices/>) has flexibility of Network-Specific abstraction, a need for more attention to connectivity parameters was identified during collaboration activity in O-RAN Alliance Working Group 9 between 3GPP SA5 representatives and IETF contributors. + +AC-draft Data Model is used as an extension of the NS NBI YANG model for a purpose to capture and reflect IETF PE connectivity to 3GPP subsystem parameters such as: + +- physical parameters of the bearer, captured in "ietf-bearer-svc" YANG Module of {{draft-boro-opsawg-teas-attachment-circuit}}, contains the physical connectivity parameters the link is utilizing, site location, (3GPP) device information, the IETF PE is connected to, and administrative operational parameters as status and activation time constraints +- logical connectivity parameters: e.g VLAN, MPLS, Segment, IPV4, IPV6 +- routing protocols + +While 3GPP NRM Rel 17 TS-28.541 Clause 6.3.18 EP\_Transport Attribute "nextHopInfoList" from Clause 6.3.18.2 is associated with "ietf-network-slice-service:network-slice-services:slice-service:sdp:sdp-ip" value, in 3GPP NRM Rel 18 TS-28.541 Clause 6.3.18 EP\_Transport Attribute list no longer contains IP address of TN element, but a link to IETF meeting point with connectionPointId value of "ietf-ac-svc:attachment-circuits:ac:name". + +Note: Possible values of Attribute, specifying the type of the connection point identifier "connectionPointIdType" are VLAN, MPLS, Segment, IPV4, IPV6, Attachment Circuit (AC). In current example Option 3 "Attachment Circuit (AC)" is used. + +The implementations of the slicing may be done in various options and some of them are depicted in figure 31 + +![Figure 31: Network slicing options. The diagram shows four options for network slicing across O-RAN and Core elements. Option 1 set 2 shows slicing on common O-RAN and Core elements. Option 2 set 2 shows slicing on common O-RAN and multiple Core elements. Option 3 set 2 shows slicing by multiple or per-slice O-CU-UP with multiple Core elements. Option 4 set 2 shows slicing by multiple or per-slice O-CU-UP with common Core elements. A legend indicates green lines for F1_U/NgU slice eMBB VLAN+IPv4/v6 or VLAN + [per-slice IPv6] and red lines for F1_U/NgU slice mMTC VLAN+IPv4/v6 or VLAN + [per-slice IPv6].](e0cabcfd411420055df5812af5433d04_img.jpg) + +**Option 1 set 2 – Network slicing on common O-RAN and Core elements** + +**Option 2 set 2 – Network slicing on common O-RAN and multiple Core elements (in DC and Edge)** + +**Option 3 set 2 – Network slicing by multiple or per-slice (optionally per slice group) O-CU-UP with multiple** + +**Option 4 set 2 – Network slicing by multiple or per-slice (optionally per slice group) O-CU-UP with common Core** + +Legend: + Green line: F1\_U/NgU slice eMBB VLAN+IPv4/v6 or VLAN + [per-slice IPv6] + Red line: F1\_U/NgU slice mMTC VLAN+IPv4/v6 or VLAN + [per-slice IPv6] + +Figure 31: Network slicing options. The diagram shows four options for network slicing across O-RAN and Core elements. Option 1 set 2 shows slicing on common O-RAN and Core elements. Option 2 set 2 shows slicing on common O-RAN and multiple Core elements. Option 3 set 2 shows slicing by multiple or per-slice O-CU-UP with multiple Core elements. Option 4 set 2 shows slicing by multiple or per-slice O-CU-UP with common Core elements. A legend indicates green lines for F1\_U/NgU slice eMBB VLAN+IPv4/v6 or VLAN + [per-slice IPv6] and red lines for F1\_U/NgU slice mMTC VLAN+IPv4/v6 or VLAN + [per-slice IPv6]. + +Figure 31 + +Slicing may be done in a way of PDU (rel.15) without any exposure to Transport Network and with this exposure bases on delineation techniques as VLAN and VLAN + IP. + +Option 1 set 2– Network slicing on common O-RAN and Core elements, where instantiated F1\_U/NgU interfaces are attached to transport element and corresponding IOC EP\_Transport of each network slice in RAN is aligned and coordinated with transport domain structure and topology with communicated transport-related parameters of SLA/SLO and traffic direction with coarse demand in accordance to the IETF model [draft-ietf-teas-ietf-network-slice-nbi-yang-02]. + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +Example of Option 1 is linear connectivity of RAN and Core entities with traditional hierarchical structure of the MNO architecture, with centrally located O-CU-UP and Core elements attached to Aggregation (HL3) and Core (HL2) transport elements, with distributed O-DUs, attached on Pre-aggregation (HL4) and access (HL5) layer of the network. + +For this example, topological diversity for the traffic profiles of different slices may have separation with QoS model [see 26 section “Transport QoS Architecture for O-RAN slicing phase 1, and 3”], Transport underlaying technologies such as G.mtn, OTN and multiple topologies with flex-algo. + +![Figure 32: High-level Network slice model abstraction diagram. The diagram shows the flow from SMO (Service Based Interface) to O-RAN and IETF domains. SMO contains 'Non RT RIC' and 'TN NSSMF'. O-RAN contains 'TN SO', 'TN NO', and 'TN DO/CM'. IETF contains 'TN SO', 'TN NO', and 'TN DO/CM'. The flow is: SMO -> O-RAN -> IETF -> O-RAN element. Annotations include: 'O1 Model Based on IOC TS28.541', 'Not specified', 'O1 termination', 'Netconf Yang/CLI', 'Device configuration Based on IOC TS28.541 O1 interface spec Yangs', 'High-level Network slice model abstraction NBI-Yang draft-ietf-teas-ietf-network-slice-nbi-yang-02', 'High-level Network slice model instantiation RFC 8969 RFC 8309 draft-ietf-ccamp-yang-otn-slicing-02', 'Network slice guidelines Section 3 [draft-barguil-teas-network-slices-instantiation-03] and [I-D.contreras-teas-slice-nbi]', 'Network soft slice model L3SM RFC 8049 L2SM RFC 8466', 'Network slice guidelines draft-srid-teas-5g-slicing-00', 'Device configuration Yang Data Model for BGP/MPLS L3 VPNs draft-ietf-beas-l3vpn-yang-05', 'YANG Model for Network Instances draft-ietf-rtgwg-ni-model-12', 'BGP YANG Model for Service Provider Networks draft-ietf-idr-bgp-model-13', 'A YANG Data Model for Routing Policy', and a note: '* Depends on the implementation May or may not be standalone modules, may be a single piece of software/package'.](f34023f99a914ab9322c026537548199_img.jpg) + +Figure 32: High-level Network slice model abstraction diagram. The diagram shows the flow from SMO (Service Based Interface) to O-RAN and IETF domains. SMO contains 'Non RT RIC' and 'TN NSSMF'. O-RAN contains 'TN SO', 'TN NO', and 'TN DO/CM'. IETF contains 'TN SO', 'TN NO', and 'TN DO/CM'. The flow is: SMO -> O-RAN -> IETF -> O-RAN element. Annotations include: 'O1 Model Based on IOC TS28.541', 'Not specified', 'O1 termination', 'Netconf Yang/CLI', 'Device configuration Based on IOC TS28.541 O1 interface spec Yangs', 'High-level Network slice model abstraction NBI-Yang draft-ietf-teas-ietf-network-slice-nbi-yang-02', 'High-level Network slice model instantiation RFC 8969 RFC 8309 draft-ietf-ccamp-yang-otn-slicing-02', 'Network slice guidelines Section 3 [draft-barguil-teas-network-slices-instantiation-03] and [I-D.contreras-teas-slice-nbi]', 'Network soft slice model L3SM RFC 8049 L2SM RFC 8466', 'Network slice guidelines draft-srid-teas-5g-slicing-00', 'Device configuration Yang Data Model for BGP/MPLS L3 VPNs draft-ietf-beas-l3vpn-yang-05', 'YANG Model for Network Instances draft-ietf-rtgwg-ni-model-12', 'BGP YANG Model for Service Provider Networks draft-ietf-idr-bgp-model-13', 'A YANG Data Model for Routing Policy', and a note: '\* Depends on the implementation May or may not be standalone modules, may be a single piece of software/package'. + +Figure 32 + +Processing high-level abstracted model of the slice on NSMF will lead to IETF model abstraction and then to activation of the transport configuration components in IETF domain as per [draft-ietf-teas-ietf-network-slices-14] and [draft-ietf-teas-ietf-network-slice-nbi-yang-02]. On the RAN side the IM/DM is done in accordance with TS.28.541 + +![Figure 33: 3GPP slice Handoff parameters diagram. The diagram shows the flow from 3GPP Rel. 16 to TN (Transport Network) and then to Edge PE(s) and UPF 1. 3GPP Rel. 16 contains 'EP_Transport' and 'EP_ApplicationRef = EP_NgU'. TN contains 'Int TenGig0/0/0/2.100', 'Ipv4 addr 1.1.1.1 255.255.255.0', 'Description cu-up1-eMBB', 'VRF embb', 'Encapsulation dot1q 100', 'Service-policy input policy cu-embb-in', and 'Service-policy output policy cu-embb-out'. Edge PE(s) contains 'Service construct 1', 'Service construct 2', 'Slice construct 1', and 'Slice construct 2'. UPF 1 contains 'EP_Transport S-NSSAI 1', 'UPF1 VLAN 1 + UPF1 IP 1', 'S-NSSAI 1', 'EP_Transport S-NSSAI 2', 'UPF1 VLAN 2 + UPF1 IP 2', 'S-NSSAI 2', and 'EP_N3 link to CU-UP N'. Annotations include: '3GPP slice Handoff parameters', 'Strict High-level requirements', 'Loose Deeper-detailed requirements/expectations', and 'PDU 1', 'PDU 2'.](a543c9cfb2028f65a96ec76f3ea4ce02_img.jpg) + +Figure 33: 3GPP slice Handoff parameters diagram. The diagram shows the flow from 3GPP Rel. 16 to TN (Transport Network) and then to Edge PE(s) and UPF 1. 3GPP Rel. 16 contains 'EP\_Transport' and 'EP\_ApplicationRef = EP\_NgU'. TN contains 'Int TenGig0/0/0/2.100', 'Ipv4 addr 1.1.1.1 255.255.255.0', 'Description cu-up1-eMBB', 'VRF embb', 'Encapsulation dot1q 100', 'Service-policy input policy cu-embb-in', and 'Service-policy output policy cu-embb-out'. Edge PE(s) contains 'Service construct 1', 'Service construct 2', 'Slice construct 1', and 'Slice construct 2'. UPF 1 contains 'EP\_Transport S-NSSAI 1', 'UPF1 VLAN 1 + UPF1 IP 1', 'S-NSSAI 1', 'EP\_Transport S-NSSAI 2', 'UPF1 VLAN 2 + UPF1 IP 2', 'S-NSSAI 2', and 'EP\_N3 link to CU-UP N'. Annotations include: '3GPP slice Handoff parameters', 'Strict High-level requirements', 'Loose Deeper-detailed requirements/expectations', and 'PDU 1', 'PDU 2'. + +Figure 33 + +Mapping of EP\_Transport Rel.17 captured artefacts to IETF domain, as per [IETF draft-gcdrb-teas-5g-network-slice-application] for a simple MidHaul F1 domain scenario, also applicable for N3/NgU BackHaul domain. + +![Figure 34: Mapping of EP_Transport Rel.17 captured artefacts to IETF domain. The diagram shows two examples of EP_Transport attributes (100 and 200) being mapped to IETF Transport Network domain elements. Each example includes a table of attributes (ipAddress, logicInterfaceInfo, nextHopInfoList, qosProfile, Attribute related to role, epApplicationRef) and a corresponding IETF attribute properties table (nextHopInfoList, String). The mapping shows how these attributes are used to configure the IETF domain, including the Ingress node, IETF slice, and Egress node, and how they relate to the O-CU-UP1 and O-DU1 components.](6c6f90b7a34ea606bed25104f4fee339_img.jpg) + +**6.3.18.2 EP\_Transport 100** + +| Attribute name | S | value | +|---------------------------|---|-------------------------| +| ipAddress | M | 1.1.1.2 | +| logicInterfaceInfo | M | port 1 vlan 100 | +| nextHopInfoList | O | string | +| qosProfile | O | eMBB | +| Attribute related to role | | | +| epApplicationRef | M | EP_F1U link to O-CU-UP1 | + +**6.4.1 Attribute properties:** + +| nextHopInfoList | String | +|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------| +| - IP address of next-hop router (the ingress node) in the transport network, it may be default GW. | 1.1.1.1 | +| - IP address and subnet mask of the attachment circuit at a RAN or CN Subnetwork end. | 1.1.1.1/16 | +| - system name. | 100 | +| - port name. | Gi1/1 | +| - VLAN ID. | 100 | +| - IP management address of transport nodes. It can use L3SM (See RFC8299 [xx]) or L2SM (See RFC8466 [yy]) in the case that the next-hop router is an L3VPN or L2VPN PE. | 198.51.100.1 | + +**6.3.18.2 EP\_Transport 200** + +| Attribute name | S | value | +|---------------------------|---|-------------------------| +| ipAddress | M | 2.2.2.2 | +| logicInterfaceInfo | M | port 1 vlan 200 | +| nextHopInfoList | O | string | +| qosProfile | O | eMBB | +| Attribute related to role | | | +| epApplicationRef | M | EP_F1U link to O-CU-UP1 | + +**6.4.1 Attribute properties:** + +| nextHopInfoList | String | +|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------| +| - IP address of next-hop router (the ingress node) in the transport network, it may be default GW. | 2.2.2.2 | +| - IP address and subnet mask of the attachment circuit at a RAN or CN Subnetwork end. | 2.2.2.2/16 | +| - system name. | 200 | +| - port name. | Gi1/1 | +| - VLAN ID. | 200 | +| - IP management address of transport nodes. It can use L3SM (See RFC8299 [xx]) or L2SM (See RFC8466 [yy]) in the case that the next-hop router is an L3VPN or L2VPN PE. | 198.51.100.2 | + +Figure 34: Mapping of EP\_Transport Rel.17 captured artefacts to IETF domain. The diagram shows two examples of EP\_Transport attributes (100 and 200) being mapped to IETF Transport Network domain elements. Each example includes a table of attributes (ipAddress, logicInterfaceInfo, nextHopInfoList, qosProfile, Attribute related to role, epApplicationRef) and a corresponding IETF attribute properties table (nextHopInfoList, String). The mapping shows how these attributes are used to configure the IETF domain, including the Ingress node, IETF slice, and Egress node, and how they relate to the O-CU-UP1 and O-DU1 components. + +Figure 34 + +EP\_Transport rel.17 TS 28.541 current status of IOC with attributes mapped to the topology with IETF terms and highlighting SDP and AC in Transport domain. + +![Figure 35: Mapping of EP_Transport Rel.17 captured artefacts to IETF domain. The diagram shows the mapping of EP_Transport attributes (100) to the IETF Transport Network domain. It includes a table of attributes (ipAddress, logicInterfaceInfo, nextHopInfoList, qosProfile, Attribute related to role, epApplicationRef) and a corresponding IETF attribute properties table (nextHopInfoList, String). The mapping shows how these attributes are used to configure the IETF domain, including the Ingress node, IETF slice, and Egress node, and how they relate to the O-DU or O-CU-UP1 and O-cloud DC fabric components. The diagram also highlights the SDP (Service Demarcation Point) and AC (Attachment Circuit) in the Transport domain.](8153914d64fece43dcd3ddc6809f417b_img.jpg) + +**6.3.18.2 EP\_Transport** + +| Attribute name | S | value | +|---------------------------|---|-------------------------| +| ipAddress | M | 1.1.1.2 | +| logicInterfaceInfo | M | port 1 vlan 100 | +| nextHopInfoList | O | string | +| qosProfile | O | eMBB | +| Attribute related to role | | | +| epApplicationRef | M | EP_F1U link to O-CU-UP1 | + +**6.4.1 Attribute properties:** + +| nextHopInfoList | String | +|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------| +| - IP address of next-hop router (the ingress node) in the transport network, it may be default GW. | 1.1.1.1 | +| - IP address and subnet mask of the attachment circuit at a RAN or CN Subnetwork end. | 1.1.1.1/16 | +| - system name. | 100 | +| - port name. | Gi1/1 | +| - VLAN ID. | 100 | +| - IP management address of transport nodes. It can use L3SM (See RFC8299 [xx]) or L2SM (See RFC8466 [yy]) in the case that the next-hop router is an L3VPN or L2VPN PE. | 198.51.100.1 | + +**SDP = Service Demarcation Point according to IETF draft-ietf-teas-ietf-network-slices-14** + +**AC = Attachment Circuit according to IETF draft-ietf-teas-ietf-network-slices-14** + +Figure 35: Mapping of EP\_Transport Rel.17 captured artefacts to IETF domain. The diagram shows the mapping of EP\_Transport attributes (100) to the IETF Transport Network domain. It includes a table of attributes (ipAddress, logicInterfaceInfo, nextHopInfoList, qosProfile, Attribute related to role, epApplicationRef) and a corresponding IETF attribute properties table (nextHopInfoList, String). The mapping shows how these attributes are used to configure the IETF domain, including the Ingress node, IETF slice, and Egress node, and how they relate to the O-DU or O-CU-UP1 and O-cloud DC fabric components. The diagram also highlights the SDP (Service Demarcation Point) and AC (Attachment Circuit) in the Transport domain. + +Figure 35 + +Mapping the 3GPP IOC attributes to IETF and WG6 O-Cloud DC Fabric implementation. + +In order to get consistent reachability and correct IETF packet switching domain artefacts the following missing information is identified as gaps for the current IOC model in 3GPP TS.28.541 in simple connectivity scenario + +O-RAN.WG9.XTRP-MGT.0-R004-v09.00 + +Image: O-RAN Alliance Logo + +**Figure 36** shows the RAN domain and IETF Transport Network domain mapping. It highlights several gaps: + +- "No port(s) towards (O)-(R)AN element" +- "No system name" +- "No L2/L3SM <=> EP\_Transport" +- "No port(s), ip prefix, gateway, PE-CE protocol" +- "No slice information pointer with related information to corelate with elApplicationRef to choose right L2/L3 for connectivity, slice parameters SLO/SLA and exit points" + +#### 6.3.18.2 EP\_Transport + +| Attribute name | S | value | +|---------------------------|---|-------------------------| +| ipAddress | M | 1.1.1.2 | +| logicInterfaceInfo | M | port 1 vlan 100 | +| nextHopInfoList | O | string | +| qosProfile | O | eMBB | +| Attribute related to role | | | +| epApplicationRef | M | EP_F1U link to O-CU-UP1 | + +*Annotation on nextHopInfoList/qosProfile:* "The String structure is hard to parse. Need to be an IOC with defined structure, values and fields" + +**Figure 36** + +When adding more complexity of multihomed solution type 1 with protection of O-Cloud DC Fabric more gaps need to be filled to have coherent reachability model. + +**Figure 37** shows the multihomed solution type 1 with protection of O-Cloud DC Fabric. Annotations include: + +- "Information exists partially, but need new structure for multihome configuration" (pointing to O-DU or O-CU-UP and O-cloud DC fabric) +- "Slice parameters shall match on all elements, but topology parameters may vary" + +**Figure 37** + +EP\_Transport SDP may be floating between multiple EP\_Transport IOCs defining port and vlan in *logicInterfaceInfo* on RAN side and single IP address with multiple physical and logical interfaces on Transport PE node. + +| | | +|----------------------------------------------------------------------------------------------------------------------------------------|-----------| +| Copyright © 2024 by the O-RAN ALLIANCE e.V.<br>Your use is subject to the copyright statement on the cover page of this specification. | <b>61</b> | +|----------------------------------------------------------------------------------------------------------------------------------------|-----------| + +![Figure 38: Network architecture diagram for Multihomed solution type 2 implementation.](0a011f4e1a8e0409fea3f377151aae75_img.jpg) + +Figure 38 illustrates the network architecture for Multihomed solution type 2 implementation. The diagram shows the following components and connections: + +- O-DU or O-CU-UP:** Contains two transport endpoints: EP\_Transport 100 (S-NSSAI 1) and EP\_Transport 200 (S-NSSAI 1). Each endpoint is connected to an interface (vlan). +- O-cloud DC fabric:** Two fabric blocks are shown. Each fabric has two interfaces: Gi1/1 and Gi1/2. Each interface is associated with an IP address. The fabrics are connected to the O-DU or O-CU-UP via their Gi1/1 interfaces. +- Information flow:** A red box indicates "Information exists partially, but need new structure for multihome configuration". Arrows point from this box to the O-cloud DC fabric and the O-DU or O-CU-UP. +- TN Element ID = system name:** A box indicating the system name for the TN Element ID. +- OAM IP address:** A box indicating the OAM IP address. +- IETF slice 1:** A blue oval representing the IETF slice 1 within the TN domain. +- TN domain:** A large blue oval representing the TN domain. +- TN Element ID:** Two boxes on the right, each containing a circle with an 'X' and a square with an 'X', representing the TN Element ID. +- Annotations:** + - A yellow box at the top right states: "Slice parameters shall match on all elements, but topology parameters may vary". + - A red box at the top left states: "Information exists partially, but need new structure for multihome configuration". + +Figure 38: Network architecture diagram for Multihomed solution type 2 implementation. + +Figure 38 + +In Multihomed solution type 2 implementation multiple IP addresses may be used per each IP address on the ingress PE node. + +![Figure 39: Network architecture diagram for Multihomed solution type 3 implementation.](cacee38349cd2eef26df1a5b135b6b1c_img.jpg) + +Figure 39 illustrates the network architecture for Multihomed solution type 3 implementation. The diagram shows the following components and connections: + +- O-DU or O-CU-UP:** Contains two transport endpoints: EP\_Transport 100 (S-NSSAI 1) and EP\_Transport 200 (S-NSSAI 1). Each endpoint is connected to an interface (vlan). +- O-cloud DC fabric:** Two fabric blocks are shown. Each fabric has two interfaces: Gi1/1 and Gi1/2. Each interface is associated with an IP address. The fabrics are connected to the O-DU or O-CU-UP via their Gi1/1 interfaces. +- Information flow:** A red box indicates "Information exists partially, but need new structure for multihome configuration". Arrows point from this box to the O-cloud DC fabric and the O-DU or O-CU-UP. +- TN Element ID = system name:** A box indicating the system name for the TN Element ID. +- OAM IP address:** A box indicating the OAM IP address. +- IETF slice 1:** A blue oval representing the IETF slice 1 within the TN domain. +- TN domain:** A large blue oval representing the TN domain. +- TN Element ID:** Two boxes on the right, each containing a circle with an 'X' and a square with an 'X', representing the TN Element ID. +- Annotations:** + - A yellow box at the top right states: "Slice parameters shall match on all elements, but topology parameters may vary". + - A red box at the top left states: "Information exists partially, but need new structure for multihome configuration". + +Figure 39: Network architecture diagram for Multihomed solution type 3 implementation. + +Figure 39 + +In Multihomed solution type 3 implementation where multiple ingress PE nodes may be used with single pair of logical interfaces and IP addresses + +![Figure 40: Network architecture diagram for Multihomed type 4. It shows two O-Cloud DC fabrics connected to two O-DU or O-CU-UP elements. Each O-DU/O-CU-UP has two EP_Transport interfaces (100 and 200) and an S-NSSAI 1. The O-Cloud DC fabrics have interfaces Gi1/1 and Gi1/2. The TN domain contains IETF slice 1 and two TN Element IDs. The diagram includes callouts: 'Information exists partially, but need new structure for multihomed configuration' (pointing to the O-DU/O-CU-UP and O-Cloud DC fabrics), 'Information exists partially, but need new structure for multihomed configuration' (pointing to the TN domain), and 'Slice parameters shall match on all elements, but topology parameters may vary' (pointing to the TN domain and TN Element IDs).](121bb09aeecf8c57c36706539fa4321c_img.jpg) + +Figure 40: Network architecture diagram for Multihomed type 4. It shows two O-Cloud DC fabrics connected to two O-DU or O-CU-UP elements. Each O-DU/O-CU-UP has two EP\_Transport interfaces (100 and 200) and an S-NSSAI 1. The O-Cloud DC fabrics have interfaces Gi1/1 and Gi1/2. The TN domain contains IETF slice 1 and two TN Element IDs. The diagram includes callouts: 'Information exists partially, but need new structure for multihomed configuration' (pointing to the O-DU/O-CU-UP and O-Cloud DC fabrics), 'Information exists partially, but need new structure for multihomed configuration' (pointing to the TN domain), and 'Slice parameters shall match on all elements, but topology parameters may vary' (pointing to the TN domain and TN Element IDs). + +Figure 40 + +As well the Multihomed type 4 with multiple interfaces and single IP address to protect O-Cloud DC Fabric interconnect with Transport ingress PE. + +![Figure 41: Network architecture diagram for Multihomed type 5. It shows two O-Cloud DC fabrics connected to two O-DU or O-CU-UP elements. Each O-DU/O-CU-UP has two EP_Transport interfaces (100 and 200) and an S-NSSAI 1. The O-Cloud DC fabrics have interfaces Gi1/1 and Gi1/2. The TN domain contains IETF slice 1 and two TN Element IDs. The diagram includes callouts: 'Information exists partially, but need new structure for multihomed configuration' (pointing to the O-DU/O-CU-UP and O-Cloud DC fabrics), 'Information exists partially, but need new structure for multihomed configuration' (pointing to the TN domain), and 'Slice parameters shall match on all elements, but topology parameters may vary' (pointing to the TN domain and TN Element IDs).](035861cb2ca07b40648c3db961127938_img.jpg) + +Figure 41: Network architecture diagram for Multihomed type 5. It shows two O-Cloud DC fabrics connected to two O-DU or O-CU-UP elements. Each O-DU/O-CU-UP has two EP\_Transport interfaces (100 and 200) and an S-NSSAI 1. The O-Cloud DC fabrics have interfaces Gi1/1 and Gi1/2. The TN domain contains IETF slice 1 and two TN Element IDs. The diagram includes callouts: 'Information exists partially, but need new structure for multihomed configuration' (pointing to the O-DU/O-CU-UP and O-Cloud DC fabrics), 'Information exists partially, but need new structure for multihomed configuration' (pointing to the TN domain), and 'Slice parameters shall match on all elements, but topology parameters may vary' (pointing to the TN domain and TN Element IDs). + +Figure 41 + +Multihomed type 5 with multiple IP addresses and interfaces may be used to deliver interconnect protection. + +More detailed view on the edge and structure with captured attributes in-between multiple SDOs + +![Figure 42: 3GPP to IETF mapping (scope of the LS). The diagram illustrates the mapping of 3GPP network elements to IETF domain constructs. On the left, two O-DU (Open Distributed Unit) blocks are shown, each containing two S-NSSAI (Network Slice Selection Assistance Information) entries. Each S-NSSAI entry is associated with an EP_F1 link to O-CU-UP1 and specific transport parameters (IP address, logic interface info, port, VLAN, next hop info). These links are mapped to a central 'PORT' block. The 'PORT' block is then mapped to a 'TN Element' block, which contains a 'L2/L3SM <-> EP_Transport Mapped by TN-NSSMF' block. This block is further mapped to a 'TE constraints' block, which is part of the 'IEEE domain'. The 'TE constraints' block is mapped to a 'Topology constraints' block, which is part of the 'IEEE domain'. The 'Topology constraints' block is mapped to a 'Pointer to object' block, which is part of the 'IEEE domain'. The 'Pointer to object' block is mapped to an 'Underlay (lower than OSI L2) Resources' block. The diagram also includes a list of constraints: Throughput constraints (Uplink_Demand, Downlink_Demand, Traffic direction), Latency constraint demand, Transport protection constraint demand, Service Level Agreement Availability value, Maximum MTU size (Payload of interest), Maximum Jitter constraint, Temporary values (activation / deactivation time stamp - activate values from XX:XX to YY:YY), and Security / Policy constraint to encode the propagation of the connectivity per domain/geography. The IETF domain is defined by draft-ietf-teas-te-service-mapping-yang.](5ed10292556817208270271f388f5aa8_img.jpg) + +3GPP<->IETF mapping (scope of the LS) + +O-DU1 + +EP\_F1 link to O-CU-UP1 + +EP\_Transport 1 for SliceSubnet S-NSSAI 1 +ipAddress = 1.1.1.2 +logicInterfaceInfo port 1 vlan 100 +nextHopInfo 1.1.1.1 + +S-NSSAI 1 + +S-NSSAI 2 + +EP\_Transport 2 for SliceSubnet S-NSSAI 1 +ipAddress = 2.1.1.2 +logicInterfaceInfo port 1 vlan 200 +nextHopInfo 2.1.1.1 + +O-DU2 + +EP\_F1 link to O-CU-UP1 + +EP\_Transport 1 for SliceSubnet S-NSSAI 1 +ipAddress = 1.1.1.5 +logicInterfaceInfo port 1 vlan 100 +nextHopInfo 1.1.1.1 + +S-NSSAI 1 + +S-NSSAI 2 + +EP\_Transport 2 for SliceSubnet S-NSSAI 1 +ipAddress = 2.1.1.5 +logicInterfaceInfo port 1 vlan 200 +nextHopInfo 2.1.1.1 + +PORT + +L2/L3SM <-> EP\_Transport Mapped by TN-NSSMF + +TE constraints + +Topology constraints + +Pointer to object + +Underlay (lower than OSI L2) Resources + +IEEE domain + +Throughput constraints: Uplink\_Demand and Downlink\_Demand, Traffic direction +Latency constraint demand +Transport protection constraint demand +Service Level Agreement Availability value +Maximum MTU size [Payload of interest] +Maximum Jitter constraint +Temporary values [activation / deactivation time stamp - activate values from XX:XX to YY:YY] +Security / Policy constraint to encode the propagation of the connectivity per domain/geography + +IETF domain +draft-ietf-teas-te-service-mapping-yang + +Unique ID of the slice [local attribute or proxy\_class]. Index, related to SR/Label + +Figure 42: 3GPP to IETF mapping (scope of the LS). The diagram illustrates the mapping of 3GPP network elements to IETF domain constructs. On the left, two O-DU (Open Distributed Unit) blocks are shown, each containing two S-NSSAI (Network Slice Selection Assistance Information) entries. Each S-NSSAI entry is associated with an EP\_F1 link to O-CU-UP1 and specific transport parameters (IP address, logic interface info, port, VLAN, next hop info). These links are mapped to a central 'PORT' block. The 'PORT' block is then mapped to a 'TN Element' block, which contains a 'L2/L3SM <-> EP\_Transport Mapped by TN-NSSMF' block. This block is further mapped to a 'TE constraints' block, which is part of the 'IEEE domain'. The 'TE constraints' block is mapped to a 'Topology constraints' block, which is part of the 'IEEE domain'. The 'Topology constraints' block is mapped to a 'Pointer to object' block, which is part of the 'IEEE domain'. The 'Pointer to object' block is mapped to an 'Underlay (lower than OSI L2) Resources' block. The diagram also includes a list of constraints: Throughput constraints (Uplink\_Demand, Downlink\_Demand, Traffic direction), Latency constraint demand, Transport protection constraint demand, Service Level Agreement Availability value, Maximum MTU size (Payload of interest), Maximum Jitter constraint, Temporary values (activation / deactivation time stamp - activate values from XX:XX to YY:YY), and Security / Policy constraint to encode the propagation of the connectivity per domain/geography. The IETF domain is defined by draft-ietf-teas-te-service-mapping-yang. + +Figure 42 + +1. L2 and L3 (+QoS DSCP parameters) identifies packets within a 3GPP slice +2. Configuration on the device is defining the mapping of attached circuit to IETF Network Slice / Service (MEF 9.x) +3. TN Management System / TN Domain Controller /TN NSSMF defines the logic of stitching of 3GPP slice and IETF Network Slice +4. IETF Network Slice objects may be mapped (many to many or one to one or many to one) to slice constructs, which may be out of IETF scope (DWDM, OTN, FlexE, ODU-Flex) objects + +## 1.2 Management and network models for Transport Network + +### 1.2.1 Segmentation of the End-to-End Network Datapath + +#### 1.2.1.1 Local Segments, Transport Segments + +The realization of the end-to-end Datapath between two Network Functions (RAN or CN) in different locations can be split into several segments. In its simplest form, we can noticeably identify local segments and transport segments: + +- *Local segments:* the production of these segments is driven by the RAN SMO via O2-I and/or O2-D interfaces. The objective of these segment is either to connect Network Functions together within a given location or to provide connectivity between a Network Function and the Transport Network. The realization of the local segment can be simple such as a direct connection between an NF SR-IOV interface and a TN node or more complex (see section 10.1.1). + +- *Transport Network Segment*: this segment is under the control of the Transport Network Orchestrator (i.e. TNO). [21] provides detail on the realization of this interconnection. + +![Figure 43 - Segmentation of the End to End datapath. The diagram illustrates the end-to-end datapath segmentation across three segments: Local Segment, TN segment, and Local Segment. At the top, the RAN SMO (Radio Access Network Service Management Orchestrator) and TN Orchestration (Transport Network Orchestrator) are shown. The RAN SMO includes RAN NSSMF, FOCOM, and NFO components, which connect via O2-I / O2-D interfaces to O-CLOUD A (site A). The TN Orchestration includes the IETF NSC component, which connects to the central Transport Network. O-CLOUD A (site A) contains two Network Function (NF) blocks, one of which is connected to the Transport Network. O-CLOUD B (site B) contains one NF block connected to the Transport Network. The Transport Network is represented by a blue box with a yellow curved line. The segments are labeled at the bottom: Local Segment, TN segment, and Local Segment.](ebeb4e2772924cd0111d20d20d8533d0_img.jpg) + +Figure 43 - Segmentation of the End to End datapath. The diagram illustrates the end-to-end datapath segmentation across three segments: Local Segment, TN segment, and Local Segment. At the top, the RAN SMO (Radio Access Network Service Management Orchestrator) and TN Orchestration (Transport Network Orchestrator) are shown. The RAN SMO includes RAN NSSMF, FOCOM, and NFO components, which connect via O2-I / O2-D interfaces to O-CLOUD A (site A). The TN Orchestration includes the IETF NSC component, which connects to the central Transport Network. O-CLOUD A (site A) contains two Network Function (NF) blocks, one of which is connected to the Transport Network. O-CLOUD B (site B) contains one NF block connected to the Transport Network. The Transport Network is represented by a blue box with a yellow curved line. The segments are labeled at the bottom: Local Segment, TN segment, and Local Segment. + +**Figure 43 - Segmentation of the End to End datapath** + +More complex cases can also happen, for example due to the segmentation of TN domains or extended site perimeters. Notwithstanding, the point of this section is to underline the segmentation of the end-to-end datapath with multiple Orchestration perimeters. + +#### 1.2.1.2 Interconnection of the 5G domains to the Transport Network + +Since local segment and TN segment are connected, the end-to-end provisioning integrates shared datapath network resources such as for example IP addresses, subnets and vlans. This shared interface is referenced here as the interconnection (see Figure 43). It is noteworthy that this interconnection can fully overlap with the local segment, for example if the Network Function is directly connected with the Transport Network. The interconnection can be seen either as an extension of the TN toward the site or vice-versa. Since this document makes no assumption on any of these approaches. For example, this view can be based on which Orchestration is responsible for the resource management of network identifiers. + +Since the provisioning of its endpoints is achieved with different Orchestrators (e.g. SMO and TNO), the interconnection introduces intrinsic complexity. In other words, Orchestrators must synchronize on datapath network resources to provision network devices. This aspect is described later in this document (see section 10.3). + +![Figure 44: Example of Interconnection between 5G sites and Transport Network. The diagram shows a RAN SMO (containing RAN NSSMF) and TN Orchestration (containing IETF NSC) connected via a dashed line. A callout box indicates 'Synchronization of datapath network resources (i.e. vlan-id, IPAM) on the interconnection link'. Below, a RAN Site (containing NF) and a Transport Network (TN) are connected via a link labeled '172.30.0.0/30' and 'vlan 100'. The link is divided into two segments: .2 on the RAN side and .1 on the TN side. A large grey arrow points to the link with the label 'Interconnection between Site and TN (NNI)'.](bad90f267214d5dea37739e8b1131718_img.jpg) + +Figure 44: Example of Interconnection between 5G sites and Transport Network. The diagram shows a RAN SMO (containing RAN NSSMF) and TN Orchestration (containing IETF NSC) connected via a dashed line. A callout box indicates 'Synchronization of datapath network resources (i.e. vlan-id, IPAM) on the interconnection link'. Below, a RAN Site (containing NF) and a Transport Network (TN) are connected via a link labeled '172.30.0.0/30' and 'vlan 100'. The link is divided into two segments: .2 on the RAN side and .1 on the TN side. A large grey arrow points to the link with the label 'Interconnection between Site and TN (NNI)'. + +**Figure 44 - Example of Interconnection between 5G sites and Transport Network** + +##### Edge TN Node + +The Edge TN Node (ETN) is the TN node that attaches to the interconnection and shares the network resources together with the 5G site. For example, in the case of an IP/MPLS Transport Network, it can be either the PE or the CE as long as it is managed by the TN orchestration. Figure 44 depicts different scenarios for the location of the Edge TN node and interconnection, depending on the existence of a Layer 3 CE, which can be either TN-managed or not. + +![Figure 45: Interconnection and Edge TN Node. The diagram shows three scenarios of interconnection between a RAN site and a Transport Network. A dashed line separates the RAN SMO domain from the TN Orchestration domain. A red arrow points to the 'Edge TN Node' label. In the first scenario, the RAN site contains an NF and a CE, which connects to a PE in the Transport Network. In the second scenario, the RAN site contains an NF and a CE, which connects to a CE in the Transport Network. In the third scenario, the RAN site contains an NF and a CE, which connects to a CE in the Transport Network. The Transport Network is represented by a green box containing a PE and a CE.](e57b87433db9ce0e8faed8cbb9f8a810_img.jpg) + +Figure 45: Interconnection and Edge TN Node. The diagram shows three scenarios of interconnection between a RAN site and a Transport Network. A dashed line separates the RAN SMO domain from the TN Orchestration domain. A red arrow points to the 'Edge TN Node' label. In the first scenario, the RAN site contains an NF and a CE, which connects to a PE in the Transport Network. In the second scenario, the RAN site contains an NF and a CE, which connects to a CE in the Transport Network. In the third scenario, the RAN site contains an NF and a CE, which connects to a CE in the Transport Network. The Transport Network is represented by a green box containing a PE and a CE. + +**Figure 45 - Interconnection and Edge TN Node** + +##### Interconnection versus IETF slice demarcation point + +![O-RAN ALLIANCE logo](cc3b132d5e82e6f10c355d04ff55855e_img.jpg) + +O-RAN ALLIANCE logo + +Note that IETF introduces the concept of “slice demarcation point” (sdp) in section 10.1.1 as the point of attachment to an IETF Network Slice. Depending on the IETF Network Slice enforcement strategy, the sdp can match the interconnection (i.e. the Attachment Circuit) or it can be located at a different place such as within a PE or CE (see Figure 42). In the case of slice enforcement via vlan handover, the sdp maps with the interconnection. + +#### 1.2.1.3 Orchestration of the end-to-end datapath + +##### 1.2.1.3.1 Objectives + +To manage a 5G slice that require connectivity between sites the following tasks must be completed: + +- **Synchronization of the datapath resources for the interconnection:** the realization of the interconnection between the 5G site and the TN requires a synchronization of network datapath resources between the SMO and the TN Orchestrator. +- **Automation for the TN Segments lifecycle:** the TN segment permits to enforce connectivity between Edge TN nodes from different sites with appropriate performance requirements. From a realization perspective, TN segments are created thanks to IETF Network Slices (see next section). +- **Automation of the Local Segment lifecycle:** only the portion of the local segment that overlaps with the interconnection between the 5G site and the TN is considered as part of this WG9 effort, the remaining fragment being covered by WG6. Indeed, this fragment is not visible from the Transport Orchestration, outside the potential configuration of routes to reach the IP subnets that are beyond the interconnection (e.g. the NF subnet behind a L3 CE managed by the RAN SMO). + +##### 1.2.1.3.2 APIs and Data Models + +The automation of the end-to-end datapath must rely on standard APIs and Data Models: + +- Within the SMO, this is handled by the 3GPPP APIs and the FIM. The 3GPP 5G NRM [31] introduces the EP\_TRANSPORT IOC to embed Datapath Network resources. This IOC is defined within the Network Slice NRM, which is a source of confusion since Network Datapath automation and 5G Slicing must rather be considered as two different dimensions. In other words, the realization of 5G deployments must rely on Network Datapath Automation irrelevant of the slicing aspect. For this purpose, the application of EP\_TRANSPORT must be generalized to all Endpoints and not be restricted to User Plane Endpoints, which is currently the case in Release 16/17. +- At the SMO – TNO interface, [draft-ietf-teas-ietf-network-slices-14] describes a framework for to achieve TN connectivity for 5G Slices with performance commitment. The general principle is that the SMO relies on abstracted “TN Slices” for ordering management. More precisely, it introduces the following definitions: + - The IETF NS provides connectivity via the Transport Network (i.e. realization of TN segments) between sites for both RAN and CN domains with performance commitment. + - The IETF NSC manages intent-based requests for IETF Network Slice instantiation via the NSI, which it maps to technology-specific realizations with adequate resource reservation. + - The IETF NSI is the NBI interface of the NSC for CRUD operations and exportation of performance metrics of Network Slices. This interface is consumed by the SMO. IETF YANG Data Models are considered for this interface, notably the “IETF Network Slice Service YANG Model” draft [draft-ietf-teas-ietf-network-slice-nbi-yang-02]. At time of writing, it appears that this latter data model has limited capabilities for configuring the Interconnection between the 5G site and the Transport Network. + +Based on 3GPP TS28.530, the 5G SMO is split into domain-specific SMO (RAN and Core)). These domains are reconciliated via an End-to-End SMO at NSMF level. 3GPP APIs permits to communicate between 3GPP domains, while the NSMF interfaces with the NSC through the IETF API interfaces. Figure 46 + +![O-RAN ALLIANCE logo](99be9500d936730cac909cdccf03deeb_img.jpg) + +O-RAN ALLIANCE logo + +describes the high-level architecture 5G SMO orchestration with a focus on Slicing and Datapath Networking integration. Note that for simplicity only mid-haul User Plane is represented. + +![Figure 46 - SMO decomposition and datapath integration. This diagram shows the 5G SMO architecture. At the top is the 5G SMO box containing E2E SMO (CSMF, NSMF), RAN SMO (RAN NSSMF, FOCOM, NFO), and CN SMO (CN NSSMF). E2E SMO connects to RAN SMO and CN SMO via 3GPP API. RAN SMO connects to the Transport Network via O2-I/O2-D. CN SMO connects to the Transport Network via Site datapath Config. The Transport Network is connected to the RAN domain (CU-UP) and CN domain (UPF).](3ac6adae71c891d0620c94af44d97e41_img.jpg) + +Figure 46 - SMO decomposition and datapath integration. This diagram shows the 5G SMO architecture. At the top is the 5G SMO box containing E2E SMO (CSMF, NSMF), RAN SMO (RAN NSSMF, FOCOM, NFO), and CN SMO (CN NSSMF). E2E SMO connects to RAN SMO and CN SMO via 3GPP API. RAN SMO connects to the Transport Network via O2-I/O2-D. CN SMO connects to the Transport Network via Site datapath Config. The Transport Network is connected to the RAN domain (CU-UP) and CN domain (UPF). + +**Figure 46 - SMO decomposition and datapath integration** + +Figure 47 depicts how Transport Network information is exchanged between domain SMO and ultimately populated to the Transport Network. Upon CRUD operation of an NSSI in a specific domain, the EP\_TRANSPORT IOC conveys the related Transport information toward the end-to-end SMO. The NSMF then propagates the changes of IETF Network Slice to the NSC. + +![Figure 47 - Transport Information carried via EP_TRANSPORT and IETF APIs. This diagram shows the flow of transport information. The 5G SMO box contains E2E SMO (CSMF, NSMF), RAN SMO, and CN SMO. E2E SMO allocates NSSI service profiles and slice profiles. RAN SMO and CN SMO allocate NSSI slice profiles. The Transport Network is connected to the RAN domain (CU-UP) and CN domain (UPF). The Transport Network is connected to the RAN domain (CU-UP) and CN domain (UPF).](45cc89f04be5ccf817e40eefed6cdeb3_img.jpg) + +Figure 47 - Transport Information carried via EP\_TRANSPORT and IETF APIs. This diagram shows the flow of transport information. The 5G SMO box contains E2E SMO (CSMF, NSMF), RAN SMO, and CN SMO. E2E SMO allocates NSSI service profiles and slice profiles. RAN SMO and CN SMO allocate NSSI slice profiles. The Transport Network is connected to the RAN domain (CU-UP) and CN domain (UPF). The Transport Network is connected to the RAN domain (CU-UP) and CN domain (UPF). + +**Figure 47 - Transport Information carried via EP\_TRANSPORT and IETF APIs** + +Hence, to automate the TN connectivity, both EP\_TRANSPORT and IETF data models must integrate all relevant attributes for the realization of the interconnection. + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +##### 1.2.1.3.3 Realization of the Datapath + +In this iteration, we will concentrate on the Use Case of a 1:1 mapping of a TN Slice to a vlan. Note that this document refers to the term vlan as a single broadcast domain. In this case, the realization of the interconnection depends mostly on the following orthogonal dimensions: + +- **L2 vs L3 Forwarding logic for the local Segment:** the forwarding mode for the local segment influences the resources and provisioning. + - In the L2 case (Figure 45), the interconnection vlan extends from the Edge TN Node to the Network Function EndPoint. This introduces dependencies, especially at IPAM level since NF have IP addresses in the subnet interconnection vlan (see). + - In the L3 case (Figure 46), we introduce here the concept of **logical gateway (lgw)**, which abstracts any routed IP realization between the Network Function and the Edge TN Node. In this case, the interconnection vlan is between the lgw and the Edge TN Node. +- **L2 vs L3 Forwarding mode for the Transport Network Segment:** the forwarding mode (e.g L2VPN or L3VPN) result in different provisioning at the interconnection level. In the case of slicing enforcement based vlan-based handover, the vlan used for the interconnection is either terminated at the Edge TN Node or extended via the TN up to the remote site. +- **Multi-homing:** The interconnection can be realized in a redundant fashion to increase availability. This impacts the datapath network resources and modelling - 3GPP and IETF YANG – for the realization of the interconnection. Figure 45 and Figure 46 depict a few examples for multihoming, refer to physical diagrams labelled as MH or FAB. + +![Figure 48 - L2 forwarding in the local segment (examples). The diagram is divided into 'Logical Design' and 'Physical Design' sections. The Logical Design section shows a Network Function (NF) connected to an Edge Transport Node (ETN) via a Vlan (nf_tn) and IP Subnet (NF_SUBNET). The Physical Design section shows various L2 forwarding topologies: L2-DSH (NF connected to ETN), L2-1SH (NF connected to ETN via a switch), L2-DMH (NF connected to two ETNs), L2-2SH (NF connected to two ETNs via a switch), L2-1MH (NF connected to two ETNs via a switch), L2-2MH (NF connected to two ETNs via a switch), L2-FAB (NF connected to two ETNs via a switch), and L2-ELAN (NF connected to ETN via an L2VPN). A legend indicates that a circle with a cross represents an Edge Transport Node and a circle with a dot represents a LAG.](f0204576e1f1176711ce4c038ef8c631_img.jpg) + +Figure 48 - L2 forwarding in the local segment (examples). The diagram is divided into 'Logical Design' and 'Physical Design' sections. The Logical Design section shows a Network Function (NF) connected to an Edge Transport Node (ETN) via a Vlan (nf\_tn) and IP Subnet (NF\_SUBNET). The Physical Design section shows various L2 forwarding topologies: L2-DSH (NF connected to ETN), L2-1SH (NF connected to ETN via a switch), L2-DMH (NF connected to two ETNs), L2-2SH (NF connected to two ETNs via a switch), L2-1MH (NF connected to two ETNs via a switch), L2-2MH (NF connected to two ETNs via a switch), L2-FAB (NF connected to two ETNs via a switch), and L2-ELAN (NF connected to ETN via an L2VPN). A legend indicates that a circle with a cross represents an Edge Transport Node and a circle with a dot represents a LAG. + +**Figure 48 - L2 forwarding in the local segment (examples)** + +![Figure 49: L3 forwarding in the local segment (examples). The diagram is divided into 'Logical Design / Abstraction' and 'Physical Design / Topologies'. The logical design shows a Network Function (NF) connected to a Logical Gateway, which is then connected to an Edge Transport Node (ETN). Two VLANs are shown: 'Vlan = nf_lgw' with IP Subnet = NF_SUBNET, and 'Vlan = lgw_tn' with IP Subnet = TN_SUBNET. The physical design shows various topologies: L3-1SH (NF connected to L3 CE), L3-1MH (NF connected to L3 CE), L3-2MH (NF connected to L3 CE via LAG), L3-FAB-BL (NF connected to Border Leaf), L3-FAB-GW (NF connected to DC GW), and L3-L3VPN (NF connected to L3 Routing). A legend indicates that a circle with 'ETN' is an Edge Transport Node and a circle with 'LAG' is a LAG.](cfbf0a48b31290a7278df08c94dae0f9_img.jpg) + +Figure 49: L3 forwarding in the local segment (examples). The diagram is divided into 'Logical Design / Abstraction' and 'Physical Design / Topologies'. The logical design shows a Network Function (NF) connected to a Logical Gateway, which is then connected to an Edge Transport Node (ETN). Two VLANs are shown: 'Vlan = nf\_lgw' with IP Subnet = NF\_SUBNET, and 'Vlan = lgw\_tn' with IP Subnet = TN\_SUBNET. The physical design shows various topologies: L3-1SH (NF connected to L3 CE), L3-1MH (NF connected to L3 CE), L3-2MH (NF connected to L3 CE via LAG), L3-FAB-BL (NF connected to Border Leaf), L3-FAB-GW (NF connected to DC GW), and L3-L3VPN (NF connected to L3 Routing). A legend indicates that a circle with 'ETN' is an Edge Transport Node and a circle with 'LAG' is a LAG. + +**Figure 49 - L3 forwarding in the local segment (examples)** + +![Figure 50: L2 vs L3 forwarding mode at Transport Network. The diagram shows two modes: L2-Forwarding Mode at TN and L3-Forwarding Mode at TN. In L2-Forwarding Mode, an IP Endpoint (NF or LGW) is connected to a TN-L2VPN, which is then connected to another IP Endpoint (NF or LGW). A single VLAN is shown: 'Vlan = ep_ep' with IP Subnet = EP_SUBNET. In L3-Forwarding Mode, an IP Endpoint (NF or LGW) is connected to a TN-L3VPN, which is then connected to another IP Endpoint (NF or LGW). Two VLANs are shown: 'Vlan = ep_tn' with IP Subnet = EP_SUBNET-A, and 'Vlan = ep_tn' with IP Subnet = EP_SUBNET-B.](38b42e1430093f10b1ba032f9271f65f_img.jpg) + +Figure 50: L2 vs L3 forwarding mode at Transport Network. The diagram shows two modes: L2-Forwarding Mode at TN and L3-Forwarding Mode at TN. In L2-Forwarding Mode, an IP Endpoint (NF or LGW) is connected to a TN-L2VPN, which is then connected to another IP Endpoint (NF or LGW). A single VLAN is shown: 'Vlan = ep\_ep' with IP Subnet = EP\_SUBNET. In L3-Forwarding Mode, an IP Endpoint (NF or LGW) is connected to a TN-L3VPN, which is then connected to another IP Endpoint (NF or LGW). Two VLANs are shown: 'Vlan = ep\_tn' with IP Subnet = EP\_SUBNET-A, and 'Vlan = ep\_tn' with IP Subnet = EP\_SUBNET-B. + +**Figure 50 - L2 vs L3 forwarding mode at Transport Network** + +##### 1.2.1.3.4 Resource inventory for EP\_TRANSPORT + +The structure of the EP\_TRANSPORT IOC is previously described in section (see section 9). The objective of this section is to describe how the mapping of network datapath resources (i.e. vlan) can be mapped to the this data structure. Since the interconnection can be realized in a myriad of fashions, this section leverages logical designs to extract requirements with limited redundancy fan-out restricted to 2. + +###### *L2 forwarding mode in the local segment* + +In this case the interconnection overlaps with the network in which Network Function are provisioned. The inventory of resources depends on the complexity of the integration. Two examples of logical representation are provided in Figure 50, with a basic interconnection and a more complex scenario with multihoming and scaled-out NF. + +The following resources are involved in the realization of the deployment: + +- Vlan for the network function NF (by default the same as the ETN, although swap can happen) : +vlan\_id + - None is also an option -, since bare ethernet is also possible + - Note that it is also possible that the vlan-id is swapped resulting in a different vlan exposed at TN and NFs. +- IP resources : + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +- IP Subnet : ip\_subnet\_nf +- IP addresses for Network Functions in the IP Subnet: ip\_nf(x) +- IP addresses for Edge Transport Nodes in the IP Subnet. Note that this is used only if the TN segment is operating in a L3 forwarding mode (i.e. non mandatory): ip\_etn(x) +- TN Gateway IP address which to be used by NFs as a next-hop for IP routes. Note that this field is used only if the TN segment is operating in a L3 forwarding mode (i.e. non mandatory field). + +![Figure 51: Logical Design for L2 forwarding mode in local segment. The diagram shows two scenarios: 'Basic' and 'Scale-out + Redundant'. In the 'Basic' scenario, a single Network Function (NF) is connected to a single Edge Transport Node (ETN) via a Logical Gateway (LGW). The NF-facing side is labeled with 'vland_id_nf' and 'ip_subnet_nf', and the TN-facing side is labeled with 'ip_etn_gw'. In the 'Scale-out + Redundant' scenario, multiple NFs are connected to multiple ETNs. The NF-facing side is labeled with 'vland_id_nf', 'ip_subnet_nf', and 'ip_nf[1..x]'. The TN-facing side is labeled with 'ip_etn1' and 'ip_etn2'.](c08e830594b0e47ef5c7c998f34a5d81_img.jpg) + +Figure 51: Logical Design for L2 forwarding mode in local segment. The diagram shows two scenarios: 'Basic' and 'Scale-out + Redundant'. In the 'Basic' scenario, a single Network Function (NF) is connected to a single Edge Transport Node (ETN) via a Logical Gateway (LGW). The NF-facing side is labeled with 'vland\_id\_nf' and 'ip\_subnet\_nf', and the TN-facing side is labeled with 'ip\_etn\_gw'. In the 'Scale-out + Redundant' scenario, multiple NFs are connected to multiple ETNs. The NF-facing side is labeled with 'vland\_id\_nf', 'ip\_subnet\_nf', and 'ip\_nf[1..x]'. The TN-facing side is labeled with 'ip\_etn1' and 'ip\_etn2'. + +**Figure 51 - Logical Design for L2 forwarding mode in local segment** + +###### *L3 forwarding in the local segment* + +The L3 case is more complex since it introduces more combinations for realization. From a realization perspective, the Logical Gateway abstraction exposes only NF-facing vs TN-facing vlans, ignoring any intermediate complexity, which is out of the scope of WG9. + +![Figure 52: Logical Design for L3 forwarding mode in local segment. The diagram shows three scenarios: 'Basic', 'Scale-out + Redundant', and 'Scale-out + Redundant' with a more complex topology. A double-headed arrow at the top indicates 'Routing protocols'. In the 'Basic' scenario, a single NF is connected to a single ETN via a Logical Gateway (LGW). The NF-facing side is labeled with 'vland_id_nf' and 'ip_subnet_nf'. The TN-facing side is labeled with 'vland_id_tnlink', 'ip_subnet_tn', and 'ip_etn1'. In the 'Scale-out + Redundant' scenario, multiple NFs are connected to multiple ETNs. The NF-facing side is labeled with 'vland_id_nf', 'ip_subnet_nf', and 'ip_nf[1..x]'. The TN-facing side is labeled with 'tn_link_id1', 'vland_id_tnlink1', 'ip_subnet_tn1', 'ip_etn1', 'tn_link_id2', 'vland_id_tnlink2', 'ip_subnet_tn2', and 'ip_etn2'. In the third scenario, the Logical Gateway is split into two parts: 'IP_nf_gw' and 'IP_lgw_gw'. The NF-facing side is labeled with 'vland_id_nf', 'ip_subnet_nf', and 'ip_nf[1..x]'. The TN-facing side is labeled with 'IP_lgw_gw', 'IP_etn_gw', 'ip_etn1', 'ip_etn2', and 'vland_id_tnlink', 'ip_subnet_tn'.](277b54f1fa9e314b1f8e14a1e5ef7714_img.jpg) + +Figure 52: Logical Design for L3 forwarding mode in local segment. The diagram shows three scenarios: 'Basic', 'Scale-out + Redundant', and 'Scale-out + Redundant' with a more complex topology. A double-headed arrow at the top indicates 'Routing protocols'. In the 'Basic' scenario, a single NF is connected to a single ETN via a Logical Gateway (LGW). The NF-facing side is labeled with 'vland\_id\_nf' and 'ip\_subnet\_nf'. The TN-facing side is labeled with 'vland\_id\_tnlink', 'ip\_subnet\_tn', and 'ip\_etn1'. In the 'Scale-out + Redundant' scenario, multiple NFs are connected to multiple ETNs. The NF-facing side is labeled with 'vland\_id\_nf', 'ip\_subnet\_nf', and 'ip\_nf[1..x]'. The TN-facing side is labeled with 'tn\_link\_id1', 'vland\_id\_tnlink1', 'ip\_subnet\_tn1', 'ip\_etn1', 'tn\_link\_id2', 'vland\_id\_tnlink2', 'ip\_subnet\_tn2', and 'ip\_etn2'. In the third scenario, the Logical Gateway is split into two parts: 'IP\_nf\_gw' and 'IP\_lgw\_gw'. The NF-facing side is labeled with 'vland\_id\_nf', 'ip\_subnet\_nf', and 'ip\_nf[1..x]'. The TN-facing side is labeled with 'IP\_lgw\_gw', 'IP\_etn\_gw', 'ip\_etn1', 'ip\_etn2', and 'vland\_id\_tnlink', 'ip\_subnet\_tn'. + +**Figure 52 - Logical Design for L3 forwarding mode in local segment** + +![O-RAN ALLIANCE logo](99be9500d936730cac909cdccf03deeb_img.jpg) + +O-RAN ALLIANCE logo + +The following resources are involved in the realization of the deployment: + +- NF attributes + - Vlan for NF (e.g. SR-IOV VF, mac-vlan, ...) + - IP Subnet and IP address for the NF +- Interconnection attributes + - tink-id for each link + - make sure each link can be identified uniquely so we can assign ip address at lgw side and tn side in a consistent manner since there are two different subnets. + - IP Subnet for each link + - IP address at TN side for each link: ip\_etn(x) + - IP address at LGW side for each link: ip\_lgw(x) + - Possibly GW/VIP at both TN And GW side, depending on the realization: ip\_lgw(x) + - Routes: + - The TN must be aware of the IPSUBNET\_NF routes with the appropriate next-hop in the interconnection vlan. For example, BGP or static routing are configured between the Logical Gateway and the Edge Transport Node. + +##### 1.2.1.3.5 EP\_TRANSPORT mapping + +The structure of EP\_TRANSPORT is described in section 9. In the case of the realization of a vlan-based slices, we c + +| | | +|-----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <i>ipAddress</i> | ip_nfx | +| <i>logicalInterfaceInfo</i> | vlan-id-nf | +| <i>nextHopInfoList</i> | <p>This field of string type (REL 17) must be used to propagate the necessary information to realize the interconnection. Note that this field has been recently redefined as a list to allow several interconnections in case of multihoming.</p> <ul style="list-style-type: none"> <li>• Vlan_id_tnlink(x) <ul style="list-style-type: none"> <li>○ This field is defined in the</li> </ul> </li> <li>• tn_link_id <ul style="list-style-type: none"> <li>○ Some identification of the link id must be integrated in the data model to differentiate links in case of multihoming and make sure LGW network attributes matches with ETN.</li> </ul> </li> <li>• ip_subnet(x) <ul style="list-style-type: none"> <li>○ This information can be derived from IP addresses, as long as the MASK is provided (ip_address + mask).</li> </ul> </li> <li>• ip_etn_x <ul style="list-style-type: none"> <li>○ ip address of the ETN</li> </ul> </li> <li>• ip_etn_vip</li> </ul> | + +| | | +|-------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>○ ip gateway at transport side if different than ip_etn_x. This is for static routing.</li> <li>• ip_lgw</li> <li>• ip_lgw_vip</li> <li>○ ip gateway from in case of static routing and multihoming realized via a shared vlan</li> </ul> <p>As of today; the realization of routing (e.g BGP) is not considered in EP_TRANSPORT.</p> | +| <i>qosProfile</i> | QoS attribute (refer to previous section ) – not related to networking – | +| <i>epApplicationRef</i> | | + +This document suggests relying exclusively on the nexthopinfolist to propagate all network datapath resources for the configuration of the Transport Network. Note that this approach results in redundant information in the case of Layer 2 forwarding (see, it provides better flexibility and a more generic framework/api processing). + +Figure 52 and Figure 53 provide examples for + +![Figure 53: Example of EP_TRANSPORT resource mapping for dual homing – L2 forwarding. The diagram shows a Network Function (NF) connected to a Transport Network (TN) via two Ethernet links (ip_etn1 and ip_etn2). The NF configuration includes Ipaddress = ip_nf1, logicalInterfaceInfo = vlan_id_nf, nextHopInfolist, qosProfile, and epApplicationRef. The nextHopInfolist contains two entries: nextHopInfo1 and nextHopInfo2, both pointing to the same logical interface. The TN configuration includes tn_link_id1, ip_etn1, ip_etn2, and ip_lgw1.](d86a32083b8f57907ba951350486dd3d_img.jpg) + +``` + +nextHopInfo1: +- link_id = tn_link_id1 +- ip_tn = ip_etn1 +- ip_tn_vip = ip_etn_gw +- ip_subnet_mask = ip_subnet_nf +- vlan_id = vlan_id_nf + +nextHopInfo2: +- link_id = tn_link_id2 +- ip_tn = ip_etn2 +- ip_tn_vip = ip_etn_gw +- ip_subnet_mask = ip_subnet_nf +- vlan_id = vlan_id_nf + +``` + +Figure 53: Example of EP\_TRANSPORT resource mapping for dual homing – L2 forwarding. The diagram shows a Network Function (NF) connected to a Transport Network (TN) via two Ethernet links (ip\_etn1 and ip\_etn2). The NF configuration includes Ipaddress = ip\_nf1, logicalInterfaceInfo = vlan\_id\_nf, nextHopInfolist, qosProfile, and epApplicationRef. The nextHopInfolist contains two entries: nextHopInfo1 and nextHopInfo2, both pointing to the same logical interface. The TN configuration includes tn\_link\_id1, ip\_etn1, ip\_etn2, and ip\_lgw1. + +**Figure 53 - example of EP\_TRANSPORT resource mapping for dual homing – L2 forwarding** + +![Figure 54: Example of EP_TRANSPORT resource mapping for dual homing – L3 forwarding (point-to-point). The diagram shows a Network Function (NF) connected to a Transport Network (TN) via two Ethernet links (ip_etn1 and ip_etn2). The NF configuration includes Ipaddress = ip_nf1, logicalInterfaceInfo = vlan_id_nf, nextHopInfolist, qosProfile, and epApplicationRef. The nextHopInfolist contains two entries: nextHopInfo1 and nextHopInfo2, each pointing to a different logical interface. The TN configuration includes tn_link_id1, ip_etn1, ip_etn2, and ip_lgw1.](88d4709e433a44856abc7a8931ee013e_img.jpg) + +``` + +nextHopInfo1: +- link_id = tn_link_id1 +- ip_tn = ip_etn1 +- ip_subnet_mask = ip_subnet_tn1_mask +- vlan_id = vlan_id_tn1 +- ip_lgw = ip_lgw1 + +nextHopInfo2: +- link_id = tn_link_id2 +- ip_tn = ip_etn2 +- ip_subnet_mask = ip_subnet_tn2_mask +- vlan_id = vlan_id_tn2 +- ip_lgw = ip_lgw2 + +``` + +Figure 54: Example of EP\_TRANSPORT resource mapping for dual homing – L3 forwarding (point-to-point). The diagram shows a Network Function (NF) connected to a Transport Network (TN) via two Ethernet links (ip\_etn1 and ip\_etn2). The NF configuration includes Ipaddress = ip\_nf1, logicalInterfaceInfo = vlan\_id\_nf, nextHopInfolist, qosProfile, and epApplicationRef. The nextHopInfolist contains two entries: nextHopInfo1 and nextHopInfo2, each pointing to a different logical interface. The TN configuration includes tn\_link\_id1, ip\_etn1, ip\_etn2, and ip\_lgw1. + +**Figure 54 - example of EP\_TRANSPORT resource mapping for dual homing – L3 forwarding (point-to-point)** + +##### 1.2.1.3.6 Gap analysis and next steps: + +###### 1. EP\_TRANSPORT enhancements + +Since the objective of *nexthopinfolist* is to describe the resources for the realization of the interconnection. It is suggested to reference a new IOC for this purpose. + +- Use a structured and non-ambiguous data model to describe the resources for the interconnection instead of a string (error-prone and limited compatibility). +- The decoupling permits to re-use of a same Nexthopinfo MOI, for several EP\_TRANSPORT + - More stability: a change in EP\_TRANSPORT is not reflected in the interconnection + +From a resource modelling perspective, a proposal was made to 3GPP, to rely on an IETF data model for this purpose (proxycass). + +| | | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <p>Missing data on the current IOC of Rel.17</p> <ul style="list-style-type: none"> <li>- IP prefix(es) and port(s) towards (O)-(R)AN element on element(s) of O-Cloud and ip prefix(es) and port(s) towards transport</li> <li>- System name(s)</li> <li>- L2/L3SM <-> EP_Transport on O-Cloud and PE edge.</li> <li>- Link and pointer to the IETF slice model</li> </ul> | <p>Since the objective of <i>nexthopinfolist</i> is to describe the resources for the realization of the interconnection. It is suggested to reference a new IOC for this purpose.</p> <ul style="list-style-type: none"> <li>• Use a structured and non-ambiguous data model to describe the resources for the interconnection instead of a string (error-prone and limited compatibility).</li> <li>• The decoupling permits to re-use of a same Nexthopinfo MOI, for several EP_TRANSPORT <ul style="list-style-type: none"> <li>◦ More stability: a change in EP_TRANSPORT is not reflected in the interconnection</li> </ul> </li> </ul> <p>From a resource modelling perspective, a proposal was made to 3GPP under [S5-225364], to rely on an IETF data model <b>pointer</b> for this purpose (proxycass).</p> | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +Missing data from section 10 and 10.1 in current EP Transport IOC + +![Figure 55: Suggested structure with optional pointers to external models and additional IOC to program O-Cloud DC Fabric to ensure basic network reachability. The diagram shows two tables, 6.3.18.2 EP_Transport and 6.3.18.2 EP_DC, with arrows indicating relationships between attributes. Below the tables, a network diagram shows the connection between O-DU or O-CU-UP, O-cloud DC fabric, and TN Element ID = system name.](289faf27d7c1a98f00c626ca89e26b33_img.jpg) + +**6.3.18.2 EP\_Transport** + +| Attribute name | S | value | +|---------------------------|---|----------------------------------| +| ipAddress (ipref) | M | 1.1.1.2 (/24) | +| logicInterfaceInfo | M | port 1 vlan 100 | +| DefaultGateway | M | 1.1.1.1 | +| nextHopInfoListRef | O | Pointer to transport IOC | +| TransportModel | O | Pointer to external model (IETF) | +| qosProfile | O | eMBB | +| Attribute related to role | | | +| epApplicationRef | M | EP_F1U link to O-CU-UP1 | + +**6.3.18.2 EP\_DC** + +| Attribute name | S | value | +|---------------------------|---|---------------------------------| +| 3GPP interface ipAddress | O | | +| 3GPP logicInterfaceInfo | O | | +| logicInstance | O | | +| TN interface ipAddress | O | | +| TN logicInterfaceInfo | O | | +| qosProfile | O | | +| Attribute related to role | | | +| EP_TransportRef | M | Link to correlated EP_Transport | + +The diagram illustrates the network architecture and data model relationships. It shows the O-DU or O-CU-UP connected to the O-cloud DC fabric, which in turn connects to the TN Element ID = system name. The EP\_Transport and EP\_DC tables define the attributes for these components, with arrows indicating the flow of data and pointers between them. The network diagram shows the O-DU or O-CU-UP connected to the O-cloud DC fabric, which in turn connects to the TN Element ID = system name. The EP\_Transport and EP\_DC tables define the attributes for these components, with arrows indicating the flow of data and pointers between them. + +Figure 55: Suggested structure with optional pointers to external models and additional IOC to program O-Cloud DC Fabric to ensure basic network reachability. The diagram shows two tables, 6.3.18.2 EP\_Transport and 6.3.18.2 EP\_DC, with arrows indicating relationships between attributes. Below the tables, a network diagram shows the connection between O-DU or O-CU-UP, O-cloud DC fabric, and TN Element ID = system name. + +Figure 55 + +Suggested structure with optional pointers to external models and additional IOC to program O-Cloud DC Fabric to ensure basic network reachability. + +#### 1.2.1.4 Mapping of Transport Network resources to IETF Data Models + +To enforce connectivity via the TN, resources must be exchanged between the SMO and NSC through IETF interfaces. The scope of the TN Slice is different than EP\_TRANSPORT. Indeed, EP\_TRANSPORT + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +integrates NF-facing information, which does not necessarily need to be exposed to the Transport Network (e.g. an IP address of a Network Function). In the case of vlan-based slice mapping the following is required: + +- link identification, especially in the case of multihoming to disambiguate the logical configuration on different nodes. +- IP subnet/pool of network functions for routing in case of L3 forwarding. +- IP address of individual TN nodes and TN Gateway address (VIP) + Mask +- vlan-id for the interconnection +- Routing: static and bgp protocols are desired to be supported with relevant attributes + +To achieve a Plug & Play TN Slice-as-a-service experience, O-RAN WG9 identified two Data Models: + +- “A YANG Data Model for the IETF Network Slice Service” [37]: this data model permits to realize the connectivity segment between ETN routers (PEs). +- “YANG Data Models for 'Attachment Circuits'-as-a-Service (ACaaS)” [38]: this data model permits to realize the connectivity between the GW and the ETN. + +These models both pertain to the IETF Service Models category, which aims at providing intent-based experience for connectivity enforcement. This approach permits to keep the 5G Network Orchestration unaware of low-level resources such as PE name and interfaces. + +![Figure 56: Data Models for the Orchestration of the Transport Network connectivity. The diagram illustrates the architecture for orchestrating transport network connectivity. At the top is the 'O-RAN Orchestration' block. Below it is the 'AC service DM / Slice service DM' block, which connects to 'TN Orchestration (IETF NSC)'. The 'TN Orchestration' block connects to a central 'Network Slice' block within the 'Transport Network (e.g. IP/MPLS)'. The 'Network Slice' block is connected to two 'O-CLOUD site' blocks (O-CLOUD site 1 and O-CLOUD site 2). Each site contains a 'GW' (Gateway) and 'NF' (Network Function) block. The 'Network Slice' block is also connected to 'AC' (Attachment Circuit) blocks, which in turn connect to the 'GW' blocks. The 'O-RAN Orchestration' block has direct connections to the 'AC service DM / Slice service DM' block and the 'AC' blocks. The 'AC service DM / Slice service DM' block also has connections to the 'TN Orchestration' block and the 'AC' blocks. The 'TN Orchestration' block has connections to the 'Network Slice' block and the 'AC' blocks. The 'Network Slice' block has connections to the 'AC' blocks and the 'GW' blocks. The 'AC' blocks have connections to the 'GW' blocks. The 'GW' blocks have connections to the 'NF' blocks. The 'NF' blocks have connections to the 'GW' blocks. The 'O-CLOUD site 1' and 'O-CLOUD site 2' blocks are connected to the 'Network Slice' block via 'ETN' (E-UTRAN) interfaces.](7e9862139b349cf411c34d889c078775_img.jpg) + +Figure 56: Data Models for the Orchestration of the Transport Network connectivity. The diagram illustrates the architecture for orchestrating transport network connectivity. At the top is the 'O-RAN Orchestration' block. Below it is the 'AC service DM / Slice service DM' block, which connects to 'TN Orchestration (IETF NSC)'. The 'TN Orchestration' block connects to a central 'Network Slice' block within the 'Transport Network (e.g. IP/MPLS)'. The 'Network Slice' block is connected to two 'O-CLOUD site' blocks (O-CLOUD site 1 and O-CLOUD site 2). Each site contains a 'GW' (Gateway) and 'NF' (Network Function) block. The 'Network Slice' block is also connected to 'AC' (Attachment Circuit) blocks, which in turn connect to the 'GW' blocks. The 'O-RAN Orchestration' block has direct connections to the 'AC service DM / Slice service DM' block and the 'AC' blocks. The 'AC service DM / Slice service DM' block also has connections to the 'TN Orchestration' block and the 'AC' blocks. The 'TN Orchestration' block has connections to the 'Network Slice' block and the 'AC' blocks. The 'Network Slice' block has connections to the 'AC' blocks and the 'GW' blocks. The 'AC' blocks have connections to the 'GW' blocks. The 'GW' blocks have connections to the 'NF' blocks. The 'NF' blocks have connections to the 'GW' blocks. The 'O-CLOUD site 1' and 'O-CLOUD site 2' blocks are connected to the 'Network Slice' block via 'ETN' (E-UTRAN) interfaces. + +**Figure 56: Data Models for the Orchestration of the Transport Network connectivity** + +An example of the provisioning of a TN slice based on this set of Data Models is provided in [37] appendix A.7. + +##### 1.2.1.4.1 Resource management + +As previously mentioned, Network datapath resources are shared for the interconnection. It is suggested here that a single Orchestrator manages these resources and exchange appropriate values thanks to the IETF NSI. In other words, even though Slice Creation is triggered from by the 5G SMO, either the 5G SMO or the NSC/TNO can be responsible for the allocation of vlan and IP subnet/addresses. + +![O-RAN ALLIANCE logo](100c8b2e5e489241b0a39f73a8896fd5_img.jpg) + +O-RAN ALLIANCE logo + +Note that by 5G SMO, we consider a the 5G orchestration domain as a whole with the integration of dependant application such as the IMS (i.e. the IMS may handle network resources which are ultimately exposed to the NSC via the 5G SMO). + +Figure 55 and Figure 56 depict examples of such provisioning workflows. Note that for the sake of simplicity, API calls are abstracted with no data model semantic. In the first case, the datapath Network resources are managed by the SMO, while in the second case, they are managed by the Transport Network and sent to the SMO in a second step. + +![Figure 57: Network Resources are managed by the SMO (or any related app such as an IMS). The diagram shows a workflow where the SMO sends a 'CREATE/MODIFY SLICE' command to the Network Slice Controller. The command includes details for creating a slice named 'EMBB' with specific link, IP, and route configurations. Below, a network diagram shows a 'New_Site' with a Network Function (NF) connected to a PE router, which is then connected to a Transport Network (TN).](54f55381ad446d116fd873025ff2e29f_img.jpg) + +``` + + graph TD + SMO[SMO] -- "IETF APIs/DM" --> NSC[Network Slice Controller] + NSC -- "CREATE/MODIFY SLICE" --> Command[Create Slice EMBB +- link_id: link_12345: +- tn_ip_prefix: 172.30.0.1/30 +- Vlan id: 100 +- Static routes 192.168.100/24 via 172.30.0.2] + subgraph Network_Diagram [Network Diagram] + New_Site[New_Site] -- "192.168.100/24" --> NF[NF] + NF -- ".2" --> PE[PE] + PE -- ".1" --> TN[TN] + PE -- "vlan 100" --> PE + PE -- "link12345" --> PE + end + +``` + +Figure 57: Network Resources are managed by the SMO (or any related app such as an IMS). The diagram shows a workflow where the SMO sends a 'CREATE/MODIFY SLICE' command to the Network Slice Controller. The command includes details for creating a slice named 'EMBB' with specific link, IP, and route configurations. Below, a network diagram shows a 'New\_Site' with a Network Function (NF) connected to a PE router, which is then connected to a Transport Network (TN). + +**Figure 57 - Network Resources are managed by the SMO (or any related app such as an IMS)** + +![Figure 58: Network Resources are managed by the TN. The diagram shows a workflow where the SMO sends a 'CREATE/MODIFY SLICE' command to the Network Slice Controller. The command includes details for creating a slice named 'EMBB' with specific link and IP configurations. Below, a network diagram shows a 'New_Site' with a Network Function (NF) connected to a PE router, which is then connected to a Transport Network (TN).](f171186b26ba5f257c55d5cff5e2fa16_img.jpg) + +``` + + graph TD + SMO[SMO] -- "IETF APIs/DM" --> NSC[Network Slice Controller] + NSC -- "CREATE/MODIFY SLICE" --> Command[Create Slice EMBB +- link_id: link_12345: +- tn_ip_prefix: 172.30.0.1/30 +- vlan-id: 100 +- ce-ip-address: 172.30.0.2/30] + NSC -- "Wait till SLICE is ready (Notification/datastore)" --> SMO + NSC -- "GET SLICE" --> Command2[Slice EMBB: +- link_id: link_12345: +- tn_ip_prefix: 172.30.0.1/30 +- vlan-id: 100 +- ce-ip-address: 172.30.0.2/30] + Command2 -- "200" --> SMO + subgraph Network_Diagram [Network Diagram] + New_Site[New_Site] -- "192.168.100/24" --> NF[NF] + NF -- ".2" --> PE[PE] + PE -- ".1" --> TN[TN] + PE -- "vlan 100" --> PE + PE -- "link12345" --> PE + end + +``` + +Figure 58: Network Resources are managed by the TN. The diagram shows a workflow where the SMO sends a 'CREATE/MODIFY SLICE' command to the Network Slice Controller. The command includes details for creating a slice named 'EMBB' with specific link and IP configurations. Below, a network diagram shows a 'New\_Site' with a Network Function (NF) connected to a PE router, which is then connected to a Transport Network (TN). + +**Figure 58 - Network Resources are managed by the TN** + +## 1.3 Management and network models of Network Slicing in ORAN subsystem + +This section describes the management and network models of Network Slicing. Notably, this section describes the RAN Management and how it relates to the transport domain. The functionality is based on + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +3GPP 28.541 clause 4 which describes RAN NRM. Related modelling documents within 3GPP are TS28.622 for the Generic NRM and TS28.620 for the FIM. Additional descriptions of the Network Slicing concepts and terminology awareness are described in the WG1 Network Slicing Architecture (see reference [35]). + +This section utilizes a deployment shown in Figure 57 where there is a mid-haul connection between DU1 and CU-UP1. It is connected through a EP\_F1U proxy and connected to EP\_Transport S-NSSAI1 in the DU1 and EP\_Transport S-NSSAI1 in the CU-UP1. + +![Figure 59 - Mid-haul connection between DU1 and CU-UP1. The diagram shows a central MIDHAUL cloud connected to DU1 (left) and CU-UP1 (right). DU1 contains S-NSSAI 1 and S-NSSAI 2, with links to CU-UP1 via EP_F1U and EP_Transport. CU-UP1 contains S-NSSAI 1 and S-NSSAI 2, with links to DU1 via EP_F1U and EP_Transport. The connections are labeled with IP addresses 4.3.13.](baab508bc3106e5771a74252963c9a4b_img.jpg) + +Figure 59 - Mid-haul connection between DU1 and CU-UP1. The diagram shows a central MIDHAUL cloud connected to DU1 (left) and CU-UP1 (right). DU1 contains S-NSSAI 1 and S-NSSAI 2, with links to CU-UP1 via EP\_F1U and EP\_Transport. CU-UP1 contains S-NSSAI 1 and S-NSSAI 2, with links to DU1 via EP\_F1U and EP\_Transport. The connections are labeled with IP addresses 4.3.13. + +Figure 59 - Mid-haul connection between DU1 and CU-UP1 + +![Figure 60: Instances of Managed functions and Network Slice Subnets (NSS). The diagram shows a hierarchical structure of Network Slice (NS) instances and their associated Network Slice Subnet (NSS) instances, which in turn group various managed function components.](b2282fc9667b4b7b01e1481310da8d6e_img.jpg) + +``` + +graph TD + NS1["NS1 +Name = 'NetworkSlice 1' +ObjectClass = 'NetworkSlice' +ServiceProfileList = 'eMBB-7Mb,eMBB-10Mb' +pLMNInfoList = '{PLMN-A:S-NSSAI-1}'"] + NS2["NS2 +Name = 'NetworkSlice 2' +ObjectClass = 'NetworkSlice' +ServiceProfileList = 'URLLC' +pLMNInfoList = '{PLMN-A:S-NSSAI-2}'"] + NSS2["NSS2 +Name = 'Top NetworkSliceSubnet instance 1' +ObjectClass = 'NetworkSliceSubnet' +SliceProfileList = 'SliceProfile#1' +pLMNInfoList = '{PLMN-A:S-NSSAI-1}'"] + NSS4["NSS4 +Name = 'Top NetworkSliceSubnet instance 2' +ObjectClass = 'NetworkSliceSubnet' +SliceProfileList = 'SliceProfile#2' +pLMNInfoList = '{PLMN-A:S-NSSAI-2}'"] + NSS3["NSS3 +Name = '5G RAN components' +ObjectClass = 'NetworkSliceSubnet' +SliceProfileList = '{RAN Profile #1};{RAN Profile #2}' +pLMNInfoList = '{PLMN-A:S-NSSAI-1};{PLMN-A:S-NSSAI-2}'"] + EpTransport1["EpTransport1 +Name = 'EP_Transport instance #1, +Transport slice 1 DU side' +ObjectClass = 'EP_Transport'"] + EpTransport2["EpTransport2 +Name = 'EP_Transport instance #2, +Transport slice 1 CU side' +ObjectClass = 'EP_Transport'"] + EpTransport3["EpTransport3 +Name = 'EP_Transport instance #3, +Transport slice 2 DU side' +ObjectClass = 'EP_Transport'"] + EpTransport4["EpTransport4 +Name = 'EP_Transport instance #4, +Transport slice 2 CU side' +ObjectClass = 'EP_Transport'"] + F1U2["F1U2 +Name = 'Midhaul EP #2 CUUP1 Side' +ObjectClass = 'EP_F1U'"] + DU1["DU1 +Name = 'O-DU instance #1' +ObjectClass = 'GNBDUFunction'"] + F1U1["F1U1 +Name = 'Midhaul EP #1 DU1 Side' +ObjectClass = 'EP_F1U'"] + CUUP1["CUUP1 +Name = 'O-CU-UP instance #1' +ObjectClass = 'GNBCUUPFunction' +pLMNInfoList = '{PLMN-A:S-NSSAI-1}'"] + + NS1 -- "«exposes»" --> NSS2 + NS2 -- "«exposes»" --> NSS4 + NSS2 -- "«groups»" --> EpTransport1 + NSS2 -- "«groups»" --> EpTransport2 + NSS4 -- "«groups»" --> EpTransport3 + NSS4 -- "«groups»" --> EpTransport4 + NSS3 -- "«groups»" --> EpTransport1 + NSS3 -- "«groups»" --> EpTransport2 + NSS3 -- "«groups»" --> EpTransport3 + NSS3 -- "«groups»" --> EpTransport4 + NSS3 -- "«groups»" --> F1U1 + NSS3 -- "«groups»" --> CUUP1 + F1U2 -- "+epApplicationRef" --> F1U1 + F1U2 -- "+epApplicationRef" --> CUUP1 + DU1 -- "«names»" --> F1U1 + DU1 -- "«names»" --> CUUP1 + EpTransport1 -- "+epTransportRef" --> F1U1 + EpTransport2 -- "+epTransportRef" --> F1U1 + EpTransport3 -- "+epTransportRef" --> F1U2 + EpTransport4 -- "+epTransportRef" --> F1U2 + +``` + +Figure 60: Instances of Managed functions and Network Slice Subnets (NSS). The diagram shows a hierarchical structure of Network Slice (NS) instances and their associated Network Slice Subnet (NSS) instances, which in turn group various managed function components. + +**Figure 60 - Instances of Managed functions and Network Slice Subnets (NSS)** + +Figure 58 above shows instances of managed functions and network slice subnets. Depicted is a Network Slice (NS1), with its associated NetworkSliceSubnet (NSS) and 5G RAN managed function components. Note that the Core function components are not shown to simplify the diagram and make the concepts more accessible. A more complete example is shown in the Network Slicing Architecture document (See reference [35]). Figure 58 illustrates that NetworkSliceSubnets are generic groupings of objects. These relationships are indicated by the <<groups>> tag. This diagram shows one eMBB Network Slice that is providing 7Mb and 10Mb services with throughput SLA requirements within the network of a service provider with identifier PLMN-A. There is a second Network Slice for PLMN-A that is an SST URLLC type slice. Notice that the NetworkSliceSubnets have SliceProfiles associated with them in this example. The illustration highlights some name containment relationships (see TS32.300 reference [36] for more details). These are indicated by the <<names>> tag. Notice that NSS3 is a collection of 5G RAN components (DU1, CUUP1, CUUP1, NRCelIDU1, NRCelICU1). + +In this description, there is a connection between DU1 and CUUP1 which is on either side of F1-U from Figure 57. The following text describes how to traverse up the overlay tree in order to identify the corresponding Network Slice information and Network Slice subnet. + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +Thus, it is possible to navigate to relevant object instances. This is illustrated in Figure #3 below. If you enter EP\_transport (S-NSSAI-1) it is possible to identify the S-NSSAI-1 associated with the DU1 and CU-UP1 from Figure 57. From there in the object model, it is possible to navigate to the NS1 and its associated attributes as described below. + +![Figure 61: Traversing & Navigating through objects. This diagram illustrates the relationships between various network objects in an O-RAN architecture. Objects are represented as boxes with their names, object classes, service profiles, and PLMN info lists. Relationships are shown as directed arrows with labels like <<exposes>>, <<groups>>, <<names>>, and <<epApplicationRef>>. Two specific paths are highlighted: Path #1 (Red Arrows) starts at EpTransport1, goes to F1U1, then to DU1, and finally to CUUP1. Path #2 (Dark Blue Arrows) starts at EpTransport2, goes to F1U2, then to CUUP1, and finally to DU1. Other objects include NS1, NS2, NSS2, NSS4, NSS3, EpTransport3, EpTransport4, and F1U1.](8b0c684809ca30be0934fd70d97e6ccc_img.jpg) + +Figure 61: Traversing & Navigating through objects. This diagram illustrates the relationships between various network objects in an O-RAN architecture. Objects are represented as boxes with their names, object classes, service profiles, and PLMN info lists. Relationships are shown as directed arrows with labels like <>, <>, <>, and <>. Two specific paths are highlighted: Path #1 (Red Arrows) starts at EpTransport1, goes to F1U1, then to DU1, and finally to CUUP1. Path #2 (Dark Blue Arrows) starts at EpTransport2, goes to F1U2, then to CUUP1, and finally to DU1. Other objects include NS1, NS2, NSS2, NSS4, NSS3, EpTransport3, EpTransport4, and F1U1. + +Figure 61 – Traversing & Navigating the through objects + +Path #1: Navigation starting at EpTransport1 (Shown in Red Arrows) + +1. Start at EpTransport1 which has epApplicationRef attribute which points to F1U1 +2. Following the red line, arriving at F1U1 +3. F1U1's FQDN has DU1. Thus, you can determine that the EpTransport1 connects to DU1 +4. EpTransport1 is grouped in the NSS2 group which has an attribute with the content of Slice Profile #1 +5. From this you can extract QoS parameters of Slice 1 applicable to EpTransport1 + +Path #2: Navigation starting at EpTransport2 (Shown in Dark Blue Arrows) + +1. Start at EpTransport2 which has epApplicationRef attribute which points to F1U2 +2. Following the red line, arriving at F1U2 +3. F1U2's FQDN has CUUP1. Thus, you can determine that the EpTransport2 connects to CUUP1 +4. EpTransport2 is grouped in the NSS2 group which has an attribute with the content of Slice Profile #1 + +- From this you can extract QoS parameters of Slice 1 applicable to EpTransport1 + +### Path #3: Navigation starting at EpTransport3 (Shown in Green Arrows) + +- Start at EpTransport3 which has epApplicationRef attribute which points to F1U1 +- Following the red line, arriving at F1U1 +- F1U1's FQDN has DU1. Thus, you can determine that the EpTransport3 connects to DU1 +- EpTransport3 is grouped in the NSS4 group which has an attribute with the content of Slice Profile #2 +- From this you can extract QoS parameters of Slice 2 applicable to EpTransport3 + +### Path #4: Navigation starting at EpTransport4 (Shown in Light Blue Arrows) + +- Start at EpTransport4 which has epApplicationRef attribute which points to F1U2 +- Following the red line, arriving at F1U2 +- F1U2's FQDN has CUUP1. Thus, you can determine that the EpTransport4 connects to CUUP1 +- EpTransport4 is grouped in the NSS4 group which has an attribute with the content of Slice Profile #2 +- From this you can extract QoS parameters of Slice 2 applicable to EpTransport4 + +![Figure 62: Objects in greater context. This is a complex network diagram showing various network objects and their relationships. Objects are represented as boxes with attributes like Name, ObjectClass, and pLMNInfoList. Relationships are shown as colored arrows: blue for '«names»', green for '«groups»', red for '+appRef', and light blue for '+transRef'. Key objects include Subnetwork1, Subnetwork100, NS2, NS1, Subnetwork3, Subnetwork4, NSS2, NSS4, EpTransport4, ME1, EpTransport3, NSS3, EpTransport1, ME2, EpTransport2, ME3, DU1, NRCelIDU1, F1U1, CUUP1, NRCelCU1, F1U2, and CUUP1. The diagram illustrates the hierarchical and functional relationships between these network components.](b26d38f02766476dee9d8a9ac94fd2f1_img.jpg) + +Figure 62: Objects in greater context. This is a complex network diagram showing various network objects and their relationships. Objects are represented as boxes with attributes like Name, ObjectClass, and pLMNInfoList. Relationships are shown as colored arrows: blue for '«names»', green for '«groups»', red for '+appRef', and light blue for '+transRef'. Key objects include Subnetwork1, Subnetwork100, NS2, NS1, Subnetwork3, Subnetwork4, NSS2, NSS4, EpTransport4, ME1, EpTransport3, NSS3, EpTransport1, ME2, EpTransport2, ME3, DU1, NRCelIDU1, F1U1, CUUP1, NRCelCU1, F1U2, and CUUP1. The diagram illustrates the hierarchical and functional relationships between these network components. + +**Figure 62 -- Objects in greater context** + +This is the same figure from Figure 58 but in a greater context. The same four Paths from Figure 59 apply in this Figure also. + +# Annex D (informative) + +## Slicing use case revision history and progress control + +This Annex contains the history and progress track record of ORAN WG9 “Management interfaces” team’s effort for definitions and standardization work in related Standards Developing Organizations (SDOs) for slicing WI, mapped to ORAN schedule. + +On Phase 4 document were captured the following WI for Phase 4 (March 2022) plan: + +Alignment with 3GPP SDO + +- Collect missing parameters in NRM TS 28.541 for TN Slice creation +- Propose enhancements of NRM TS 28.541 to include OpenModelClass TNSliceSubnet to link EP\_Transport to TN and add options for linking 3GPP subsystems to TN subsystems +- File O-RAN liaison to SA5 in order to augment TS 28.541 with missing information and proposed items. +- Align with IETF TN Network Slice abstraction + +Phase 4 (March 2022) delivery: + +Alignment with 3GPP SDO + +- Sent O-RAN liaison to SA5 [S-2022003](https://oranalliance.atlassian.net/wiki/download/attachments/247693332/S2022003%20-%20LS%20on%20O-RAN%20-%20Transport%20Network%20Slicing%20Enhancement%20IM%20DM%20TS28.541.docx?api=v2): +<https://oranalliance.atlassian.net/wiki/download/attachments/247693332/S2022003%20-%20LS%20on%20O-RAN%20-%20Transport%20Network%20Slicing%20Enhancement%20IM%20DM%20TS28.541.docx?api=v2> + +Alignment with IETF SDO + +- Published Merged draft “IETF Network Slice Application in 3GPP 5G End-to-End Network Slice” +<https://datatracker.ietf.org/doc/draft-gcdrb-teas-5g-network-slice-application/> +- Published “A Realization of IETF Network Slices for 5G Networks Using Current IP/ MPLS Technologies”. <https://datatracker.ietf.org/doc/draft-srld-teas-5g-slicing/> + +Phase 5 (November 2022) plan + +- Fill the gap in Missing data on the current IOC of Rel.17: + - IP prefix(es) and port(s) towards (O)-(R)AN element on element(s) of O-Cloud and ip prefix(es) and port(s) towards transport + - System name(s) + - L2/L3SM <> EP\_Transport on O-Cloud and PE edge. + - Link and pointer to the IETF slice model + +Since the objective of *nexthopinfo* is to describe the resources for the realization of the interconnection. It is suggested to reference a new IOC for this purpose. + +- Use a structured and non-ambiguous data model to describe the resources for the interconnection instead of a string (error-prone and limited compatibility). +- The decoupling permits to re-use of a same Nexthopinfo MOI, for several EP\_TRANSPORT + - More stability: a change in EP\_TRANSPORT is not reflected in the interconnection + - From a resource modelling perspective, a proposal was made to 3GPP under [S5-225364], to rely on an IETF data model **pointer** for this purpose (proxycass). + +Phase 5 (November 2022) delivery + +Alignment with 3GPP SDO + +- The preliminary answer form Samsung is received from SA5 + +![O-RAN ALLIANCE logo](100c8b2e5e489241b0a39f73a8896fd5_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN' in blue, with 'ALLIANCE' in smaller blue letters below it. + +O-RAN ALLIANCE logo + +- The feedback is not what we expected from SA5 +- 4+ meetings with clarifications and discussion were conducted with Samsung representatives and the group of contributors from WG9 +- The outcome is multidirectional with no consensus on 3GPP IM/DM and WG9. + +## Alignment with IETF SDO + +- Improving IETF Slice Realization and Slice Application drafts with co-authors + +### Phase 6 (March 2023) delivery + +- Submit next LS to 3GPP SA5 with clarification request and suggestion for structuring *nexthopinfo* into key values table. +- Conclude IETF Slice Realization and Slice Application drafts +- Suggest improvement of IETF NBI-YANG Network Slice Data Model with AC Data Model +- Align with WG6 for Data Model of the Network Slice + +# Annex E (informative) + +## Use cases for the direct integration of transport into SMO / Non-RT RIC + +This Annex describes use cases which require the support of transport by SMO / Non-RT RIC respectively make the direct integration of transport into SMO / Non-RT RIC the preferred option when compared to the integration via an external transport network management system. + +It shall be noted that use cases UC 0.1 - Fully integrated O-gNB and UC 0.2 - O-DU/CU in a physical device are not actually about the integration of transport devices into SMO / Non-RT RIC but about the support of transport functionality within O-RAN devices. + +### Use case 0.1: Fully integrated O-gNB + +Many of the 5G RAN systems deployed in production networks are fully integrated, i.e. O-RU/DU/CU functionality in a single box, an O-gNB. At its management interface, the O-gNB should therefore expose all status, configuration, alarm and performance data as O-RU, O-DU and O-CU together. Only the functionality relating to Fronthaul and Mid-haul need not be supported. In parallel to disaggregated RAN components the O-gNB should be integrated into the SMO / Non-RT RIC. The transport port and associated transport functionality should therefore be supported by SMO / Non-RT RIC as shown on the figure below. + +![Diagram illustrating the integration of transport into SMO / Non-RT RIC for a fully integrated O-gNB. The diagram shows the SMO and Non-RT RIC (dashed box) connected to the Near-RT RIC. The Near-RT RIC is connected to the O-gNB via the E2 interface. The O-gNB is connected to the Backhaul (represented by an oval) via the ETH interface. The Backhaul is connected to the 5GCN. The O1 interface connects the SMO and Non-RT RIC to the O-gNB. The A1 interface connects the Non-RT RIC to the Near-RT RIC.](9746772a9b6b17945a7fb5ac246814fb_img.jpg) + +``` + +graph TD + SMO[SMO] --- O1[O1] --- O_gNB[O-gNB] + Non_RT_RIC[Non-RT RIC] --- O1[O1] --- O_gNB + Non_RT_RIC -.- A1[A1] --- Near_RT_RIC[Near-RT RIC] + Near_RT_RIC --- E2[E2] --- O_gNB + O_gNB --- ETH[ETH] --- Backhaul((Backhaul)) + Backhaul --- 5GCN[5GCN] + +``` + +Diagram illustrating the integration of transport into SMO / Non-RT RIC for a fully integrated O-gNB. The diagram shows the SMO and Non-RT RIC (dashed box) connected to the Near-RT RIC. The Near-RT RIC is connected to the O-gNB via the E2 interface. The O-gNB is connected to the Backhaul (represented by an oval) via the ETH interface. The Backhaul is connected to the 5GCN. The O1 interface connects the SMO and Non-RT RIC to the O-gNB. The A1 interface connects the Non-RT RIC to the Near-RT RIC. + +It shall be noted that a 4G O-eNB should be supported by SMO / Non-RT RIC in the same way. + +Since the O1 interface of the O-gNB should support transport functionality, the same general rules as of Section 4 – Modelling Schema should be applied to the O1 YANG models, i.e. + +- models should use YANG RFC 7950 [1] as schema, +- models should be under open-source license, +- models should have modular structure with clearly defined augmentation mechanism, +- models selected should be independent of specific supplier attributes, +- vendor-specific augmentations should be temporary only, where temporary is defined here as less than one year, +- models should support backwards compatibility and future-proof enhancement solution. + +### Use case 0.2: O-DU/CU in a physical device + +Despite the trend towards virtualizing / containerizing network functions the performance of hardware-based respectively assisted O-DU is often higher and the power consumption lower. Therefore, the O-DU/CU may come in a fully integrated physical device as displayed hereafter. + +O-RAN.WG9.XTRP-MGT.0-R004-v09.00 + +Image: O-RAN ALLIANCE Logo + +Image: O-RAN Architecture Diagram showing SMO, Non-RT RIC, Near-RT RIC, O-DU/CU, O-RUs, and 5GCN connected via various interfaces like O1, A1, E2, eCPRI, and ETH. + +Similar to classical RRH / BBU configurations with split 8 and CPRI between RRH and BBU, O-DU/CU +has transport interfaces typically connected by fibre-optical cables to the O-RUs. Now, however, the O-RUs +may come from different vendors. And, therefore, the SMO / Non-RT RIC should manage the transport +interfaces on O-RU and O-DU/CU as well as the cabling in between. + +**Use case 1: O-DU at antenna site** + +Especially if the antenna site is connected via microwave radio, also referred to as wireless transport, with +limited and variable data rates, the O-DU is often located at the antenna site as shown on the figure below. In +such a scenario the fronthaul switch aggregating the traffic from the O-RUs is considered part of the RAN. +To more easily monitor the tight requirements imposed on the fronthaul network the fronthaul switch should +be preferably managed by SMO / Non-RT RIC as shown on the following figure. + +Image: Use case 1 Diagram showing O-DU at antenna site with O-FH Switch, SMO, Non-RT RIC, Near-RT RIC, O-CU, and 5GCN connected via O1, A1, E2, IETF, and ETH interfaces. + +**Use case 2: End-to-end sync management** + +Along with SyncE for frequency synchronization, also referred to as syntonization, the precision time +protocol (PTP) acc. to IEEE 1588 has become the predominant technology for time synchronization. Indeed, +the sync plane (S-plane) is, in parallel the user (U-plane), control (C-plane) and management plane (M- +plane) a network in its own right reaching from the PTP GMC via various transport segments and +technologies down to the O-RUs as shown on the next figure. + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +Your use is subject to the copyright statement on the cover page of this specification. + +84 + + + +In contrast to public 5G networks operated by MNOs, there are only a few devices per device category. The IT departments of vertical organizations usually have only a small staff whereas MNOs dispose of departments per device category. For this reason, network management should be much simpler, i.e. a single management system should manage the entire communications network. An easy-to-use SMO is needed that integrates not only RAN but also transport and 5G Core network functions. + +### Use case 4: Administrative Domains for RAN, Transport, and Core + +Basically, the overall network management requirements of a large-scale, country-wide mobile network are similar to the ones of a private 5G campus network. Only that there are tens of thousands of devices per device category. And that there are still administrative domains per network segment as illustrated hereafter. + +![Architecture diagram for Use Case 4: Administrative Domains for RAN, Transport, and Core. The diagram shows a hierarchical management structure. At the top is the 'E2E Management System OSS'. Below it are four main management domains: 'SMO' (Service Management and Orchestration), 'Non-RT RIC' (Non-Real-Time Resource Intelligent Controller), 'Transport Management System', and 'Core Management System'. The 'SMO' and 'Non-RT RIC' are connected to a 'Near-RT RIC' (Near-Real-Time Resource Intelligent Controller). The 'Near-RT RIC' is connected to the 'O-DU' (Open Distributed Unit) via an 'E2' interface. The 'O-DU' is connected to the 'Mid-haul' via an 'ETH' interface. The 'Mid-haul' is connected to the 'O-CU' (Open Central Unit) via an 'ETH' interface. The 'O-CU' is connected to the 'Backhaul' via an 'ETH' interface. The 'Backhaul' is connected to the '5GCN' (5G Core Network) via a '3GPP-I/F' interface. The 'E2E Management System OSS' is connected to the 'SMO' via an 'O1' interface, to the 'Non-RT RIC' via an 'O1' interface, to the 'Transport Management System' via a 'TR-Mgmt.-I/F' interface, and to the 'Core Management System' via a '3GPP-I/F' interface. The 'SMO' is also connected to the 'O-FH M-Plane' (Open F1-M Plane) via an 'O1' interface. The 'O-FH M-Plane' is connected to the 'O-FH Switch' (Open F1-M Switch) via an 'ETH' interface. The 'O-FH Switch' is connected to the 'O-DU' via an 'ETH' interface. The 'O-DU' is connected to the 'O-CU' via an 'ETH' interface. The 'O-CU' is connected to the 'Backhaul' via an 'ETH' interface. The 'Backhaul' is connected to the '5GCN' via a '3GPP-I/F' interface. The 'O-RU' (Open Radio Unit) is connected to the 'O-FH Switch' via an 'ETH' interface.](66f1a6b4fae2c2334ad905222fb29d99_img.jpg) + +Architecture diagram for Use Case 4: Administrative Domains for RAN, Transport, and Core. The diagram shows a hierarchical management structure. At the top is the 'E2E Management System OSS'. Below it are four main management domains: 'SMO' (Service Management and Orchestration), 'Non-RT RIC' (Non-Real-Time Resource Intelligent Controller), 'Transport Management System', and 'Core Management System'. The 'SMO' and 'Non-RT RIC' are connected to a 'Near-RT RIC' (Near-Real-Time Resource Intelligent Controller). The 'Near-RT RIC' is connected to the 'O-DU' (Open Distributed Unit) via an 'E2' interface. The 'O-DU' is connected to the 'Mid-haul' via an 'ETH' interface. The 'Mid-haul' is connected to the 'O-CU' (Open Central Unit) via an 'ETH' interface. The 'O-CU' is connected to the 'Backhaul' via an 'ETH' interface. The 'Backhaul' is connected to the '5GCN' (5G Core Network) via a '3GPP-I/F' interface. The 'E2E Management System OSS' is connected to the 'SMO' via an 'O1' interface, to the 'Non-RT RIC' via an 'O1' interface, to the 'Transport Management System' via a 'TR-Mgmt.-I/F' interface, and to the 'Core Management System' via a '3GPP-I/F' interface. The 'SMO' is also connected to the 'O-FH M-Plane' (Open F1-M Plane) via an 'O1' interface. The 'O-FH M-Plane' is connected to the 'O-FH Switch' (Open F1-M Switch) via an 'ETH' interface. The 'O-FH Switch' is connected to the 'O-DU' via an 'ETH' interface. The 'O-DU' is connected to the 'O-CU' via an 'ETH' interface. The 'O-CU' is connected to the 'Backhaul' via an 'ETH' interface. The 'Backhaul' is connected to the '5GCN' via a '3GPP-I/F' interface. The 'O-RU' (Open Radio Unit) is connected to the 'O-FH Switch' via an 'ETH' interface. + +In this scenario completely different management systems can be used per network segment as long as the E2E management system gets the required information from the management system of each segment, also referred to as domain controllers. Just by comparing the figures of UC 0.1 with the one of this UC it becomes obvious that the disaggregation of the RAN implicitly disaggregates the transport networks making its management significantly more fragmented and thus more complex. Later on, it will be shown that there is an advantage for direct transport integration in SMO / Non-RT RIC even in this use case. + +### Impact on SMO / Non-RT RIC architecture + +The figure hereafter depicts the current SMO / Non-RT RIC architecture as of R003. Most of the components are not actually RAN-specific but provide functionality that is required in more or less each domain controller irrespective of whether it manages radio access networks, microwave networks, optical networks, packet switched networks or core networks. Only the blue bordered components are actually RAN-specific with some rApps being also RAN-specific. + +NFO and FOCOM are only needed whenever network functions are virtualized and deployed on a cloud infrastructure (O-Cloud). It is not relevant whether the virtual network functions are RAN components like O-DU and O-CU, transport network components like virtual routers or core components like UPF. + +![Diagram of the SMO architecture showing the connection between various management and orchestration components and the underlying network planes.](a6fee58ea6308479c60f45046f4d731f_img.jpg) + +The diagram illustrates the SMO (Service Management and Orchestration) architecture. It shows a central horizontal bus with several components connected to it: SME, DME, TE&IV, SO&A, rApp Mgmt., and rApp (R1). Below the bus, there are components for NFO, FOCOM, FM, CM, PM, and A1 related services. These components are connected to the O2, O-FH M-Plane, O1, and A1 interfaces. The O2 interface connects to O-Cloud. The O-FH M-Plane connects to O-RU. The O1 interface connects to Near-RT RIC and O1 Nodes. The A1 interface connects to Near-RT RIC and O1 Nodes. The A1 related services are part of the Non-RT RIC. The rApp Mgmt. and rApp (R1) are part of the SMOS Communication. + +**Legend:** + +- DME: Data Management and Exposure +- FOCOM: Federated O-Cloud Orchestration and Management +- NFO: Network Function Orchestrator +- SME: Service Management and Exposure +- SO&A: Service Orchestration and Assurance +- TE&IV: Topology Exposure & Inventory + +Diagram of the SMO architecture showing the connection between various management and orchestration components and the underlying network planes. + +The fault, configuration and performance management components are each attached to two different southbound interfaces, O-FH M-Plane and O1. These two interfaces are quite different in nature such that FM, CM and PM need to be decomposed. The next figure illustrates this using the example of fault management. + +![Diagram illustrating the decomposition of fault management components into O-FH M-Plane and O1 interfaces.](8a8c881227c68d1523bf0ad40b06b429_img.jpg) + +This diagram shows the decomposition of fault management components. The SMO architecture is shown on the left, with the same components as the previous diagram. The A1 related services are highlighted. On the right, a detailed view of the fault management application is shown. It includes a Fault Management Application, SMOS Communication, Translation to Uniform Alarm Model, and Termination of NETCONF Notifications and VES Messages. The O-FH M-Plane connects to O-RU, and the O1 interface connects to O-DU/CU. + +**Legend:** + +- DME: Data Management and Exposure +- FOCOM: Federated O-Cloud Orchestration and Management +- NFO: Network Function Orchestrator +- SME: Service Management and Exposure +- SO&A: Service Orchestration and Assurance +- TE&IV: Topology Exposure and Inventory + +Diagram illustrating the decomposition of fault management components into O-FH M-Plane and O1 interfaces. + +Whereas alarms come in as NETCONF Notifications on the O-FH M-Plane, the O1 interface uses VES messages for this purpose. This results in two different protocol termination functions. Whereas NETCONF Notifications are used elsewhere, VES messages are only used in connection with the O1 interface and can therefore be considered as RAN-specific. + +Also the alarm models the O-FH M-Plane does not use the 3GPP models as the O1 interface does. Depending on the alarm model adopted by the fault management application the one or the other interface requires translation. In no case is the fault management application RAN-specific but should nevertheless be orchestrated like an rApp. + +Likewise, the configuration management component can be decomposed. In this case, only the translation functions are RAN-specific as shown hereafter. + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +![Architecture diagram showing SMO and Config. Management Application components and their interactions.](8677a5e51448a3599cce1cf25534c903_img.jpg) + +The diagram illustrates the Service Based Interface (SBI) architecture for the O-RAN Management Plane (O-MP). It is divided into two main sections: the SMO (Service Based Interface) and the Config. Management Application. + +**SMO Section:** + +- Top Layer:** Includes SME (Service Management and Exposure), DME (Data Management and Exposure), TE&IV (Topology Exposure and Inventory), SO&A (Service Orchestration and Assurance), rApp Mgmt., and rApp (R1). +- Second Layer:** Includes NFO (Network Function Orchestrator), FOCOM (Federated O-Cloud Orchestration and Management), FM (Fault Management), CM (Configuration Management), PM (Policy Management), and A1 related services. +- Third Layer:** Includes O-Cloud, O-FH M-Plane, O-RU, and A1 (Near-RT RIC, O1 Nodes). +- Interfaces:** O2, O-FH M-Plane, O1, and A1. + +**Config. Management Application Section:** + +- Top Layer:** Config. Management Application. +- Second Layer:** Translation to Uniform Device Model, Termination of NETCONF Configs. +- Third Layer:** O-FH M-Plane, O-RU, O-DU/CU. +- Interfaces:** SMOS Communication, O-FH M-Plane, O1. + +**Legend:** + +- DME: Data Management and Exposure +- FOCOM: Federated O-Cloud Orchestration and Management +- NFO: Network Function Orchestrator +- SME: Service Management and Exposure +- SO&A: Service Orchestration and Assurance +- TE&IV: Topology Exposure and Inventory + +Architecture diagram showing SMO and Config. Management Application components and their interactions. + +When integrating an O-FH Switch as of UC 1 the fault management architecture does not change as can be easily seen on the next figure. Nor does the configuration management architecture as depicted on the next but one figure. + +![Architecture diagram showing Fault Management and Config. Management Applications and their interactions.](b52f7154ddcfdc97047a11680f1bc7a7_img.jpg) + +The diagram illustrates the Fault Management and Configuration Management architectures for the O-RAN Management Plane (O-MP). + +**Fault Management Application:** + +- Top Layer:** Fault Management Application. +- Second Layer:** Translation to Uniform Alarm Model, Termination of NETCONF Notifications, Termination of VES Messages. +- Third Layer:** O-FH M-Plane, O-RU, O-FH Switch, O-DU/CU. +- Interfaces:** SMOS Communication, O-FH M-Plane, IETF, O1. + +**Config. Management Application:** + +- Top Layer:** Config. Management Application. +- Second Layer:** Translation to Uniform Device Model, Termination of NETCONF Configs. +- Third Layer:** O-FH M-Plane, O-RU, O-FH Switch, O-DU/CU. +- Interfaces:** SMOS Communication, O-FH M-Plane, IETF, O1. + +Architecture diagram showing Fault Management and Config. Management Applications and their interactions. + +Usually, a domain controller does not only manage the devices but also the links between the devices like in UC 0.2. Often, the links cannot be unambiguously read from the network but the enrichment of the information retrieved from the devices by topology data stored in an enrichment database is needed. For the sake of simplicity, the management of the links connecting the devices and thus the network topology should be done by a Topology Management Function implemented as an rApp. + +![Diagram of O-RAN architecture for UC 1 (End-to-End Sync Management).](bc05c54a82610eee722814b2f4c00839_img.jpg) + +This diagram illustrates the O-RAN architecture for UC 1 (End-to-End Sync Management). At the top, a horizontal line represents 'SMOS Communication'. Above this line are two applications: 'Config. Management Application' and 'Topology Management Application'. Below the line is an 'Enrichment DB' (database). The architecture is divided into three main functional blocks, each connected to the SMOS Communication line via a 'Termination of NETCONF Configs' block. These blocks are: + + +- 'O-FH M-Plane': Connected via 'Termination of NETCONF Configs' to 'Translation to Uniform Device Model', which then connects to 'O-FH M-Plane'. +- 'IETF': Connected via 'Termination of NETCONF Configs' to 'Translation to Uniform Device Model', which then connects to 'IETF'. +- 'O1': Connected via 'Termination of NETCONF Configs' to 'Translation to Uniform Device Model', which then connects to 'O1'. + + The bottom layer shows the physical network components: 'O-RU' (Radio Unit) connected to 'O-FH Switch' (O-FH M-Plane), which is connected to 'O-DU/CU' (O1) via 'ETH' (Ethernet) links. + +Diagram of O-RAN architecture for UC 1 (End-to-End Sync Management). + +UC 2 – End-to-End Sync Management should be realized in a similar fashion as depicted next. Again, Sync. Management could be implemented as an rApp. + +![Diagram of O-RAN architecture for UC 2 (End-to-End Sync Management).](d23fddf7083fca3a20102acbc95b062e_img.jpg) + +This diagram illustrates the O-RAN architecture for UC 2 (End-to-End Sync Management). The 'SMOS Communication' line at the top now includes four applications: 'Fault Management Application', 'Config. Management Application', 'Topology Management Application', and 'Sync. Management Application'. The 'Enrichment DB' remains on the left. The architecture is divided into five main functional blocks, each connected to the SMOS Communication line via a 'Termination of NETCONF' or 'Termination of Transport Mgmt. IFs' block. These blocks are: + + +- 'O-FH M-Plane': Connected via 'Termination of NETCONF' to 'Translation to Uniform Device Model', which then connects to 'O-FH M-Plane'. +- 'IETF': Connected via 'Termination of NETCONF' to 'Translation to Uniform Device Model', which then connects to 'IETF'. +- 'O1': Connected via 'Termination of NETCONF / VES' to 'Translation to Uniform Device Model', which then connects to 'O1'. +- 'Transport Mgmt. IFs': Connected via 'Termination of Transport Mgmt. IFs' to 'Translation to Uniform Device Model', which then connects to 'Transport Mgmt. IFs' (IETF, BBF, OpenROADM ...). +- 'IEEE': Connected via 'Termination of NETCONF' to 'Translation to Uniform Device Model', which then connects to 'IEEE'. + + The bottom layer shows the physical network components: 'O-RU' connected to 'O-FH Switch' (O-FH M-Plane), which is connected to 'O-DU/CU' (O1) via 'ETH' links. 'O-DU/CU' is connected to 'Transport Devices' (Transport Mgmt. IFs) via 'ETH' links, which are then connected to 'PTP GMC' (IEEE) via 'ETH' links. + +Diagram of O-RAN architecture for UC 2 (End-to-End Sync Management). + +The most comprehensive scenarios can be found in private 5G campus networks where all transport management functions are implemented as rApps including the network slicing ones as can be seen on the next picture. + +![Diagram of O-RAN architecture for private 5G campus networks with network slicing.](33e60d06890a8ee27cd3a6a8d91e9b53_img.jpg) + +This diagram illustrates the O-RAN architecture for private 5G campus networks with network slicing. The 'SMOS Communication' line at the top includes five applications: 'CSMF' (Control Plane Service Management Function), 'NSMF' (Network Slice Management Function), 'NSSMF RAN' (Network Slice Sub-Mgmt. RAN), 'NSSMF Transport', and 'NSSMF Core'. A blue callout box labeled 'Network Slice Creation Req.' points to the 'CSMF' application. The 'Enrichment DB' is on the left. The architecture is divided into five main functional blocks, each connected to the SMOS Communication line via a 'Termination of NETCONF' or 'Termination of Transport Mgmt. IFs' block. These blocks are: + + +- 'O-FH M-Plane': Connected via 'Termination of NETCONF' to 'Translation to Uniform Device Model', which then connects to 'O-FH M-Plane'. +- 'IETF': Connected via 'Termination of NETCONF' to 'Translation to Uniform Device Model', which then connects to 'IETF'. +- 'O1': Connected via 'Termination of NETCONF / VES' to 'Translation to Uniform Device Model', which then connects to 'O1'. +- 'Transport Mgmt. IFs': Connected via 'Termination of Transport Mgmt. IFs' to 'Translation to Uniform Device Model', which then connects to 'Transport Mgmt. IFs' (IETF, BBF, OpenROADM ...). +- '3GPP': Connected via 'Termination of Core Mgmt. IF' to 'Translation to Uniform Device Model', which then connects to '3GPP'. + + The bottom layer shows the physical network components: 'O-RU' connected to 'O-FH Switch' (O-FH M-Plane), which is connected to 'O-DU/CU' (O1) via 'ETH' links. 'O-DU/CU' is connected to 'Transport Devices' (Transport Mgmt. IFs) via 'ETH' links, which are then connected to '5GCN' (3GPP) via 'ETH' links. + +Diagram of O-RAN architecture for private 5G campus networks with network slicing. + +In public networks where there are still administrative domains, network slicing could be implemented in a similar way as in private 5G campus networks only that there would be an SMO deployment per domain as shown next. + +![Architecture diagram of the O-RAN XTRP-MGT system showing the flow from Network Slice Creation Request through SMO E2E, RAN Domain, Transport Domain, and Core Domain to various network elements.](1f74b5a15416d9cdd60679ae4a53678f_img.jpg) + +The diagram illustrates the XTRP-MGT architecture across four domains, connected by a central SMOS Communication bus. + +- Network Slice Creation Req.**: Initiates the process, passing through the **SMO E2E** domain. +- SMO E2E**: Contains **CSMF** and **NSMF** components, which interact with an **Enrichment DB** and the **SMOS Communication** bus. +- RAN Domain**: Contains the **SMO RAN** block, which includes **NSSMF RAN**. It receives data from the bus and performs **Translation to Uniform Device Model** and **Termination of NETCONF** / **NETCONF / VES**. It connects to **O-RU** via **O-FH M-Plane** and **O-DU/CU** via **O1**. +- Transport Domain**: Contains the **SMO Transport** block, which includes **NSSMF Transport**. It receives data from the bus and performs **Translation to Uniform Device Model** and **Termination of Transport Mgmt. IFs**. It connects to **Transport Devices** via **TR Mgmt. IF (IETF, BBF, OpenROADM...)**. +- Core Domain**: Contains the **SMO Core** block, which includes **NSSMF Core**. It receives data from the bus and performs **Translation to Uniform Device Model** and **Termination of Core Mgmt. IF**. It connects to **5GCN** via **3GPP**. + +Architecture diagram of the O-RAN XTRP-MGT system showing the flow from Network Slice Creation Request through SMO E2E, RAN Domain, Transport Domain, and Core Domain to various network elements. + +## Use cases for the coordinated interface between transport management and SMO + +This section describes the use cases that are supported by coordination of management systems of RAN and transport networks via standard interfaces, aiming to achieve optimized network performance, elevate operational efficiency, and enhance deployment flexibility. Note that the transport network and RAN network (together with their management systems) are still logically separated and the collaboration between the two networks are achieved via coordinated interfaces as shown in the following figure. + +![Architecture diagram showing the coordinated interface between SMO, External Transport Network Management System, and the RAN/Transport network components.](6ae6bd6c0bf297ee9a156fad13083852_img.jpg) + +The diagram illustrates the architecture for coordinated management between the SMO and the External Transport Network Management System. The SMO contains a Non-RT RIC and a Near-RT RIC. The External Transport Network Management System is connected to the SMO via a Standard Interface (dashed red line). The SMO connects to the RAN components (O-RU, O-DU, O-CU) through interfaces O1, O-FH M-Plane, A1, and E2. The External Transport Network Management System connects to the RAN components through interfaces TR-Mgmt-IF and TR-Mgmt-IF. The RAN components are connected to the Transport network components (Mid-haul, Backhaul, 5GCN) through interfaces ETH and E2. The diagram also shows a legend for RAN (grey line) and Transport (blue line). + +Architecture diagram showing the coordinated interface between SMO, External Transport Network Management System, and the RAN/Transport network components. + +### Use case 1.1: Automated and Joint Network Provisioning of RAN and Transport Network + +This use case outlines a scenario where the Radio Access Network (RAN) and transport network's provisioning processes are seamlessly integrated and automated. By leveraging coordinated management systems between RAN and transport networks, operators can deploy network resources efficiently, ensuring optimal connectivity and performance, ultimately realizing the target of end-end zero-touch provisioning. + +#### Process: + +- A service request initiates the automated provisioning workflow, identifying the required resources and configurations for both the RAN and the transport network. +- The coordinated management systems assess the current network state, including available resources, capacity, and potential bottlenecks. +- Based on predefined rules and real-time data, the coordinated management systems dynamically allocate resources across the RAN and transport networks, optimizing for performance, cost, and availability. +- Configurations are automatically applied across both networks, ensuring compatibility and optimal integration of RAN and transport elements. +- The coordinated management systems perform a comprehensive check to confirm successful provisioning and readiness for service delivery. + +#### Benefits: + +- Efficiency: Streamlines the provisioning process, reducing manual efforts and the potential for errors. +- Scalability: Enables rapid scaling of network resources to meet changing demands. + +![O-RAN ALLIANCE logo](100c8b2e5e489241b0a39f73a8896fd5_img.jpg) + +O-RAN ALLIANCE logo + +- Optimization: Ensures optimal use of network resources, enhancing overall performance. + +![Diagram illustrating the information exchange between the RAN Network and the Transport Network via a Standard Interface. The RAN Network (left) includes SMO, O-RU, O-DU, O-CU, and 5GCN. The Transport Network (right) includes Transport Management, Fronthaul, Mid-haul, and Backhaul. A Standard Interface connects SMO and Transport Management. Coordinated management systems are shown as a dashed line between the two networks.](e810c4a896fb20a4685086c65463de8a_img.jpg) + +Info exchange over the interface + +- Service demand & requirement +- Inventory availability +- Network topology +- Provisioning commands +- Service activation & test feedback +- ... + +``` + +graph LR + subgraph RAN_Network [RAN Network] + SMO[SMO] + O_RU[O-RU] + O_DU[O-DU] + O_CU[O-CU] + 5GCN[5GCN] + end + subgraph Transport_Network [Transport Network] + TM[Transport Management] + FH[Fronthaul] + MH[Mid-haul] + BH[Backhaul] + end + SMO <--> |Standard Interface| TM + SMO <--> |Coordinated management systems| TM + SMO <--> |Coordinated management systems| TM + +``` + +Diagram illustrating the information exchange between the RAN Network and the Transport Network via a Standard Interface. The RAN Network (left) includes SMO, O-RU, O-DU, O-CU, and 5GCN. The Transport Network (right) includes Transport Management, Fronthaul, Mid-haul, and Backhaul. A Standard Interface connects SMO and Transport Management. Coordinated management systems are shown as a dashed line between the two networks. + +An example of information flows across the interface is illustrated in the above figure with more description below: + +- Service Demand & Requirement & data: Geographic areas of demand, predicted user growth, data traffic patterns. +- Inventory Availability: List of available RUs, BBUs, and transport resources including specifications and current deployment statuses. +- Network Topology: Optimal configurations for RUs, BBUs placement, and transport connections based on algorithms considering latency, throughput, and redundancy. +- Provisioning Commands: Specific sequenced configuration settings for RUs, BBUs, and transport links; IP address assignments; and any special routing or security protocols. +- Service Activation & Testing Feedback: Performance metrics such as connectivity, throughput, and latency measurements; service quality indicators. + +### Use case 1.2: Cloud RAN Adaptation for Resilience and Energy Efficiency + +This use case focuses on utilizing the coordinated management systems to adapt Cloud RAN deployments for improved resilience and energy efficiency. By dynamically adjusting RAN and transport network configurations based on real-time conditions and demands, networks can achieve greater operational sustainability and reliability. + +Process: + +- Real-time monitoring tools assess network performance, user demand, and environmental conditions of both RAN and transport Networks. +- Based on the collected data, the coordinated management systems identify opportunities to adjust RAN and transport configurations for improved energy efficiency without compromising service quality. +- Resources are dynamically allocated or de-allocated, and power settings are adjusted across the C-RAN and associated transport network elements. +- The coordinated management systems implement resilience strategies, such as rerouting traffic through alternative paths during outages or peak loads, ensuring continuous service availability to adapt to current network conditions and demands. +- Continuous monitoring and adjustments maintain optimal performance and efficiency levels. + +![O-RAN ALLIANCE logo](3194145ff4fb03bf0f9bbb7971116689_img.jpg) + +O-RAN ALLIANCE logo + +#### Benefits: + +- Resilience: Enhances network reliability through proactive adjustments and redundancy strategies. +- Energy Efficiency: Reduces power consumption by optimizing resource usage and operational parameters based on actual needs. +- Cost Savings: Lowers operational expenses by improving energy efficiency and reducing the need for physical interventions. + +![Diagram illustrating information exchange between the RAN Network and the Transport Network. The RAN Network (left) includes SMO, O-RU, O-DU, O-CU, and 5GCN. The Transport Network (right) includes Transport Management, Fronthaul, Mid-haul, and Backhaul. A 'Standard Interface' (dashed red line) connects SMO and Transport Management. Below this interface is the label 'Coordinated management systems'. Arrows indicate bidirectional communication between SMO and the RAN Network, and between Transport Management and the Transport Network.](a3d4d29cf7e7bec526fd7b98c93f8fde_img.jpg) + +Info exchange over the interface + +- Real-time network performance data +- Environmental and Operational Conditions +- Fault Management Data +- Topology and Configuration Adjustment +- Adaption feedback and perforce metrics +- ... + +Diagram illustrating information exchange between the RAN Network and the Transport Network. The RAN Network (left) includes SMO, O-RU, O-DU, O-CU, and 5GCN. The Transport Network (right) includes Transport Management, Fronthaul, Mid-haul, and Backhaul. A 'Standard Interface' (dashed red line) connects SMO and Transport Management. Below this interface is the label 'Coordinated management systems'. Arrows indicate bidirectional communication between SMO and the RAN Network, and between Transport Management and the Transport Network. + +Above figure provides an example of information exchange cross the interface: + +- Real-time Performance Data: Metrics related to network traffic load, bandwidth usage, latency, error rates, and user demand patterns. +- Environmental and Operational Conditions: Data on external conditions affecting network operation, such as temperature, time of day, and special event schedules. Information on energy-saving adjustments, like reducing power during low demand periods or cooling requirements. +- Fault Management Data: Information on network vulnerabilities, potential failure points, and historical fault data. +- Topology and Configuration Adjustments: Sequenced configuration & commands for changes in network topology or component configurations to enhance resilience and energy efficiency. +- Adaptation Feedback and Performance Metrics: Post-adaptation performance metrics, measuring the effectiveness of changes in terms of resilience, energy efficiency, and user experience. + +### Use case 1.3: Integrated Maintenance and Troubleshooting + +This use case illustrates the benefits of a coordinated approach to maintenance and troubleshooting across the RAN and transport networks. By sharing data and insights between these layers, network operators can quickly identify, diagnose, and resolve issues, minimizing downtime and improving service quality. + +#### Process: + +- The system continuously monitors the health and performance of both RAN and transport network components. Fault and Alert Notification triggers immediate attention to potential issues, facilitating swift troubleshooting and resolution. +- Upon detecting an anomaly, the coordinated management systems correlate data from both networks to accurately pinpoint the issue's location and nature from multiple reported faults and alarms. +- Automated and joint diagnostics are run to assess the problem and identify potential solutions to provide insights into the root cause of issues and recommended corrective actions. If necessary, alerts are escalated to human operators with detailed insights. + +![O-RAN ALLIANCE logo](7fb3c0ff0eabc7948da26f9bc02b6158_img.jpg) + +O-RAN ALLIANCE logo + +- Remediation actions are automatically applied where possible, or guided procedures are provided to field technicians for manual interventions. +- Post-resolution, the system documents the incident and solution, enhancing future diagnostics and preventing recurrence. + +#### Benefits: + +- **Rapid Response:** Accelerates the identification and resolution of issues, reducing downtime and improving user experience. Specially avoid unnecessary dispatching workers to remote cell sites. +- **Proactive Maintenance:** Identifies potential issues before they impact service, allowing for preventative maintenance. +- **Knowledge Building:** Enhances the knowledge base for troubleshooting and maintenance, streamlining future operations. + +![Diagram showing information exchange between SMO and Transport Management over a Standard Interface. The SMO is connected to the RAN Network (O-RU, O-DU, O-CU, 5GCN). The Transport Management is connected to the Transport Network (Fronthaul, Mid-haul, Backhaul). A dashed red line separates the two networks, with 'Standard Interface' and 'Coordinated management systems' labels.](874133836aed96cd6fe46becfcc6d0b2_img.jpg) + +Info exchange over the interface + +- Health and Performance Data +- Fault and Alert Notifications +- Diagnostic Data Analysis reports +- Remediation actions +- Resolution Feedback and Performance Validation +- ... + +``` + +graph TD + SMO[SMO] <-->|Standard Interface| TM[Transport Management] + SMO <--> RN[RAN Network] + TM <--> TN[Transport Network] + RN --- O-RU[O-RU] + RN --- O-DU[O-DU] + RN --- O-CU[O-CU] + RN --- 5GCN[5GCN] + TN --- FH[Fronthaul] + TN --- MH[Mid-haul] + TN --- BH[Backhaul] + SMO -.-> TM + TM -.-> SMO + +``` + +Diagram showing information exchange between SMO and Transport Management over a Standard Interface. The SMO is connected to the RAN Network (O-RU, O-DU, O-CU, 5GCN). The Transport Management is connected to the Transport Network (Fronthaul, Mid-haul, Backhaul). A dashed red line separates the two networks, with 'Standard Interface' and 'Coordinated management systems' labels. + +Above figure provides an example of information exchange cross the interface: + +- **Network Health and Performance Data:** Real-time and historical data on network performance metrics, including signal strength, bandwidth utilization, latency, packet loss, and error rates. +- **Fault and Alert Notifications:** Automated alerts generated by network components and monitoring systems upon detecting faults or deviations from normal operational parameters. +- **Diagnostic Data and Analysis Reports:** Detailed diagnostic results and analysis reports generated after initial fault detection, including potential causes and suggested fixes. +- **Remediation actions:** Solutions and remediation steps generated upon identifying network issues, including configuration changes, hardware replacement, or software updates. +- **Resolution Feedback and Performance Validation:** Feedback on the success of troubleshooting and maintenance actions, including post-resolution performance metrics. + +# Annex F (informative) + +## Mapping 3GPP NRM to IETF Network Slice IM/DM + +This section describes relationships between network slice informational model definitions of 3GPP NRM TS 28.541 section 6, IETF Yang network slice Data Model with Attachment circuit Yang Data Model and ORAN O2 Information Model / Data Model. + +In current version 3GPP TS 28.541 IM/DM is mapped to IETF DMs, since WG6 DM is still under development. + +![Diagram showing the mapping of 3GPP NRM to IETF Network Slice IM/DM. It illustrates the connection between 3GPP NRM TS 28.541 (O-DU-1 and O-CU-UP-1) and IETF Yang DM NS+AC (TPNE1, TPN, TPNE2) through the O-RAN WG5 IM/DM.](0c1ccbcf7cd691adff95cd65b3996ff0_img.jpg) + +The diagram illustrates the mapping of 3GPP NRM to IETF Network Slice IM/DM. It shows three main components: 3GPP NRM TS 28.541 (O-DU-1), IETF Yang DM NS+AC (TPNE1, TPN, TPNE2), and 3GPP NRM TS 28.541 (O-CU-UP-1). The O-DU-1 and O-CU-UP-1 are connected to the IETF Yang DM NS+AC via TPNE1 and TPNE2. The O-RAN WG5 IM/DM is shown at the bottom, indicating the mapping from 3GPP NRM to IETF Yang DM. + +Diagram showing the mapping of 3GPP NRM to IETF Network Slice IM/DM. It illustrates the connection between 3GPP NRM TS 28.541 (O-DU-1 and O-CU-UP-1) and IETF Yang DM NS+AC (TPNE1, TPN, TPNE2) through the O-RAN WG5 IM/DM. + +Here: TPN - Transport Provider Network +TPNE - Transport Provider Network Edge + +Agreement within WG9 and 3GPP with liaison # S-2022003 “Transport Network Slicing Enhancement IM/DM TS28.541” to 3GPP SA5, resulting in 3GPP TS 28.541 Clause 6.3.18 and IETF draft-ietf-teas-ietf-network-slice-nbi-yang augmented with draft-boro-opsawg-teas-attachment-circuit is captured on the following diagram: + +![Diagram showing the mapping of 3GPP NRM to IETF Network Slice IM/DM. It illustrates the connection between 3GPP NRM TS 28.541 (O-DU and O-CU-UP) and IETF Yang DM NS+AC (TPNE1, TPN, TPNE2) through the O-RAN WG5 IM/DM.](14ea6df6e81de64fc6390f4cbc573571_img.jpg) + +The diagram illustrates the mapping of 3GPP NRM to IETF Network Slice IM/DM. It shows a 3GPP NRM TS 28.541 (O-DU and O-CU-UP) connected to an IETF Yang DM NS+AC (TPNE1, TPN, TPNE2) via TPNE1 and TPNE2. The O-RAN WG5 IM/DM is shown at the bottom, indicating the mapping from 3GPP NRM to IETF Yang DM. + +Diagram showing the mapping of 3GPP NRM to IETF Network Slice IM/DM. It illustrates the connection between 3GPP NRM TS 28.541 (O-DU and O-CU-UP) and IETF Yang DM NS+AC (TPNE1, TPN, TPNE2) through the O-RAN WG5 IM/DM. + +Current Annex E reflects work done in IETF draft-ietf-teas-5g-network-slice-application extended to ORAN focus and scope of definitions. + +Information model in 3GPP Clause 6.3.18 is linked to Data Model in IETF draft-ietf-teas-ietf-network-slice-nbi-yang with draft-boro-opsawg-teas-attachment-circuit extension in the fashion of External Object Class defined in 6.3.41 ConnectionPointInfo. + +ConnectionPointInfo is linked to the IETF DM draft-boro-opsawg-teas-attachment-circuit, linked, in turn, in IETF draft-ietf-teas-5g-network-slice-application to every SDP (Service Demarcation Point) of the Transport Network Slice DM. + +![O-RAN ALLIANCE logo](c1888483d75b57066b8a079cb636f8dc_img.jpg) + +O-RAN ALLIANCE logo + +As IETF draft-ietf-teas-ietf-network-slice-nbi-yang and draft-ietf-teas-5g-network-slice-application are not defining and not giving the guidance on the location of SDP, it could be on the 3GPP Subsystem Element and on TPNE element, the draft-ietf-teas-5g-network-slice-application section “Example According to PE-mode with Meeting Point Extension of ACaaS (OPTION 3)” with IETF draft-ietf-teas-5g-ns-ip-mpls in agreement defines SDP location on TNPE elements with logically connected 3GPP or ORAN WG5 subsystems. + +The following diagram depicts logical connectivity of the elements with IM and DM on each of the element in the example of the relationship of (O)-DU-1 and (O)-CU-UP-1 with the Transport Network element(s) connecting them in Network Slicing fashion. + +![Diagram showing logical connectivity between O-DU-1 and O-CU-UP-1 via TPNE1 and TPN elements. Below each element is a detailed configuration block.](461876e8bc7518eae59725e61a696bca_img.jpg) + +``` + +graph LR + ODU1[O-DU-1] <--> TPNE1_1[TPNE1] + TPNE1_1 --- TPN((TPN)) + TPN --- TPNE1_2[TPNE1] + TPNE1_2 <--> OCUP1[O-CU-UP-1] + +``` + +**O-DU-1 Configuration:** + +``` + +---DU1--- +3GPP NRM {{TS-28.541}} Clause 6.3.18 EP_Transport +ipAddress: '1.1.1.1/24' +localLogicalInterfaceInfo: "DU1_LogicalInterfaceInfo" +qosProfile: '5QI100' +connectionPointRefList: "DU1_Meeting_point" + +3GPP NRM Rel 18 {{TS-28.541}} Clause 6.3.35 LogicalInterfaceInfo: "DU1_LogicalInterfaceInfo" +logicalInterfaceType: 'VLAN' +logicalInterfaceId: '100' +systemName: 'DU1' +portName: 'XE' +routingProtocol: 'Static' + +3GPP NRM {{TS-28.541}} Clause 6.3.41 ConnectionPointInfo: "DU1_Meeting_point" +connectionPointId: 'ac01-DU1' +connectionPointIdType: 'Attachment_Circuit' + +3GPP NRM {{TS-28.623}} Clause A 2.2.2 IOC ManagedElement +id: 'DU1' +locationName: 'Site1.AAA1.ZIP1' + +``` + +**O-CU-UP-1 Configuration:** + +``` + +---CU-UP-1--- +3GPP NRM {{TS-28.541}} Clause 6.3.18 EP_Transport +ipAddress: '100.1.1.1/24' +localLogicalInterfaceInfo: "CU-UP1_LogicalInterfaceInfo" +qosProfile: '5QI100' +connectionPointRefList: "CU-UP1_Meeting_point" + +3GPP NRM Rel 18 {{TS-28.541}} Clause 6.3.35 LogicalInterfaceInfo: "CU-UP1_LogicalInterfaceInfo" +logicalInterfaceType: 'VLAN' +logicalInterfaceId: '100' +systemName: 'CU-UP1' +portName: 'XE' +routingProtocol: 'Static' + +3GPP NRM {{TS-28.541}} Clause 6.3.41 ConnectionPointInfo: "CU-UP1_Meeting_point" +connectionPointId: 'ac01-CU-UP1' +connectionPointIdType: 'Attachment_Circuit' + +3GPP NRM {{TS-28.623}} Clause A 2.2.2 IOC ManagedElement +id: 'CU-UP1' +locationName: 'Site1.AAA2.ZIP2' + +``` + +Diagram showing logical connectivity between O-DU-1 and O-CU-UP-1 via TPNE1 and TPN elements. Below each element is a detailed configuration block. + +![O-RAN ALLIANCE logo](3847fbb17a2cf56b2f3f602649461beb_img.jpg) + +O-RAN ALLIANCE logo + +![Diagram showing the relationship between O-DU-1, TPNE1, TPN, and O-CU-UP-1. The diagram is divided into two main sections: the top section shows the O-DU-1 and O-CU-UP-1 connected to TPNE1, which is connected to TPN. The bottom section shows the O-DU-1 and O-CU-UP-1 connected to TPNE1, which is connected to TPN. The diagram includes two large boxes containing JSON-like data representing the configuration of the O-DU-1 and O-CU-UP-1.](32b2adeeb6875e9ed4d0495e5d07c2a4_img.jpg) + +The diagram illustrates the relationship between O-DU-1, TPNE1, TPN, and O-CU-UP-1. The top section shows the O-DU-1 and O-CU-UP-1 connected to TPNE1, which is connected to TPN. The bottom section shows the O-DU-1 and O-CU-UP-1 connected to TPNE1, which is connected to TPN. The diagram includes two large boxes containing JSON-like data representing the configuration of the O-DU-1 and O-CU-UP-1. + +**O-DU-1 Configuration:** + +``` + +Slice Yang +{ + "data": { + "ietf-network-slice-service-network-slice-services": { + "slo-sle-templates": { + "slo-sle-template": { + "id": "5Q100", /* QoS profile as in EP_Transport */ + "template-description": "5Q100 description", + "slice-service": { + "service-id": "5GSliceMapping-PE-mode", + "service-description": "example 5G Slice mapping following PE mode", + "slo-sle-template": "5Q100", /* QoS profile as in EP_Transport */ + "status": "active", + "sdp": { + "sdp": { + "sdp-id": "01", + "node-id": "PE1", + "ac-svc-name-ac-ref": { + "ac01-DU1" + } + } + } + } + } + } + } + } +} + +``` + +**O-CU-UP-1 Configuration:** + +``` + +"ietf-ac-svc:attachment-circuits": { + "ac": { + { + "name": "ac01-DU1", + "description": "meeting point DU1-PE1", + "l2-connection": { + "encapsulation": { + "type": "ietf-vpn-common:dot1q", + "logicalInterfaceType": "VLAN" + }, + "dot1q": { + "cvlan-id": 100 + } + } + } + } +} + +``` + +**O-DU-1 Configuration (Bottom):** + +``` + +"ip-connection": { + "ipv4": { + "local-address": "100.1.1.254", + "prefix-length": 24, + "address": { + "address-id": "1", + "customer-address": "100.1.1.1" + } + } +} + +``` + +**O-CU-UP-1 Configuration (Bottom):** + +``` + +"ietf-ac-svc:ietf-bearer-svc": { + "bearers": { + { + "id": "line-156" /* Note that bearer-reference is returned in the response */ + "description": "link DU1-PE1" + "customer-point": { + "identified-by": "ietf-bearer-svc:site-and-device-id", + "device": { + "device-id": "DU1" + } + } + } + } +} + +``` + +Diagram showing the relationship between O-DU-1, TPNE1, TPN, and O-CU-UP-1. The diagram is divided into two main sections: the top section shows the O-DU-1 and O-CU-UP-1 connected to TPNE1, which is connected to TPN. The bottom section shows the O-DU-1 and O-CU-UP-1 connected to TPNE1, which is connected to TPN. The diagram includes two large boxes containing JSON-like data representing the configuration of the O-DU-1 and O-CU-UP-1. + +The following table represents relationships that shall be expected between attributes in 3GPP / ORAN WG5 IM/DMs and IETF DMs in case of the directly associated (O)-RAN and TPNE elements. Each line represents the mapping of the attributes from (O)-RAN subsystem O-DU-1 perspective and TPNE1 perspective, with formed CE-PE relationship. + +![O-RAN ALLIANCE logo](4a7c448fa7d1201fff49f20089531bb2_img.jpg) + +O-RAN ALLIANCE logo + +| 3GPP TS28.541, WG5 IM/DM Spec Attribute | Attribute value example | IETF DM draft-boro-opsawg-teas-attachment-circuit | Attribute value example | IETF DM draft-ietf-teas-ietf-network-slice-nbi-yang | Attribute value example | +|---------------------------------------------------------|----------------------------|--------------------------------------------------------------------------------|-----------------------------------|-------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------| +| | | | | data.ietf-network-slice-service:network-slice-services.name | Network_Slice_1 | +| | | ietf-ac-svc:attachment-circuits.ac.id | ac01-O-DU1 | data.ietf-network-slice-service:network-slice-services.slice-service.sdps.sdp.ac-svc-name:ac-ref | ac01-O-DU1 | +| Clause 6.3.41 EP_Transport.ipAddress | 1.1.1.1 | ietf-ac-svc:attachment-circuits.ac.ip-connection.ipv4.address.customer-address | 1.1.1.1 | network-slice-services.slice-service.Network_Slice_1.sdps.sdp.01.attachment-circuits.ac01-O-DU1.ac-ipv4-address ( <i>optional</i> ) | | +| Clause 6.3.41 EP_Transport.localLogicalInterfaceInfo | O-DU1_LogicalInterfaceInfo | | | | | +| Clause 6.3.41 EP_Transport.qosProfile | 5QI100 | attachment-circuits.ac.ac01-O-DU1.service.qos.qos-profiles.qos-profile | May differ from ORAN/3GPP profile | network-slice-services.slice-service.Network_Slice_1.sdps.sdp.01.incoming-qos-policy ( <i>optional</i> ) | May differ from ORAN/3GPP profile | +| Clause 6.3.41 EP_Transport.externalEndPointRefList | O-DU1_Meeting_point | | | | | +| Clause 6.3.35 LogicalInterfaceInfo | O-DU1_LogicalInterfaceInfo | | | | | +| Clause 6.3.35 LogicalInterfaceInfo.logicalInterfaceType | VLAN | attachment-circuits.ac.ac01-O-DU1.l2-connection.encapsulation.type | VLAN | network-slice-services.slice-service.Network_Slice_1.sdps.sdp.01.attachment- | VLAN | + +![O-RAN ALLIANCE logo](4a7c448fa7d1201fff49f20089531bb2_img.jpg) + +O-RAN ALLIANCE logo + +| | | | | | | +|----------------------------------------------------------------|-----------------------------------|-----------------------------------------------------------------------------------------|------------------|-----------------------------------------------------------------------------------------------------------------------------------|------------------| +| | | | | circuits.ac01-O-DU1.ac-tags.tag-type ( <i>optional</i> ) | | +| Clause 6.3.35<br>LogicalInterfaceInfo<br>.logicalInterfaceId | 100 | attachment-circuits.ac.ac01-O-DU1.l2-connection.encapsulation.dot1q.cvlan-id | 100 | network-slice-services.slice-service.Network_Slice_1.sdps.sdp.01.attachment-circuits.ac01-O-DU1.ac-tags.value ( <i>optional</i> ) | 100 | +| Clause 6.3.35<br>LogicalInterfaceInfo<br>.systemName | O-DU1 | ietf-bearer-svc.bearers.line-156.customer-point.device.device-id | O-DU1 | network-slice-services.slice-service.Network_Slice_1.sdps.sdp.01.attachment-circuits.ac01-O-DU1.ac-node-id ( <i>optional</i> ) | O-DU1 | +| Clause 6.3.35<br>LogicalInterfaceInfo<br>.portName | XE1 | Not in the model | | network-slice-services.slice-service.Network_Slice_1.sdps.sdp.01.attachment-circuits.ac01-O-DU1.ac-tp-id ( <i>optional</i> ) | XE1 | +| Clause 6.3.35<br>LogicalInterfaceInfo<br>.routingProtocol | Static | attachment-circuits.ac.ac01-O-DU1.routing-protocols.id.1.ietf-vpn-common:static-routing | Static | Not in the model | | +| Clause 6.3.41<br>ConnectionPointInfo | <a href="#">DU1_Meeting_point</a> | | | | | +| Clause 6.3.41<br>ConnectionPointInfo.<br>connectionPointId | ac01-O-DU1 | ietf-ac-svc:attachment-circuits.ac.ac01-O-DU1 | Name containment | network-slice-services.slice-service.Network_Slice_1.sdps.sdp.01.attachment-circuits.ac01-O-DU1 | Name containment | +| Clause 6.3.41<br>ConnectionPointInfo.<br>connectionPointIdType | ATTACHMENT_CIRCUIT | Not in the model | | Not in the model | | + +![O-RAN ALLIANCE logo](100f56efac29ab5756a69598750ab957_img.jpg) + +The logo for the O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN ALLIANCE' in blue and green. + +O-RAN ALLIANCE logo + +| 3GPP TS28.623, WG5 IM/DM Spec Attribute | Example value | IETF DM draft-ietf-teas-ietf-network-slice-nbi-yang | Example value | IETF DM draft-boro-opsawg-teas-attachment-circuit | Attribute value example | +|------------------------------------------------|-----------------|------------------------------------------------------------------|-----------------|--------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| Clause A 2.2.2 IOC ManagedElement.id | O-DU1 | ietf-bearer-svc.bearers.line-156.customer-point.device.device-id | O-DU1 | network-slice-services.slice-service.Network_Slice_1.sdps.sdp.01.attachment-circuits.ac01-O-DU1.ac-node-id ( <i>optional</i> ) | O-DU1 | +| Clause A 2.2.2 IOC ManagedElement.locationName | Site1.AAA1.ZIP1 | ietf-bearer-svc.bearers.line-156.customer-point.site.site-id | Site1.AAA1.ZIP1 | network-slice-services.slice-service.Network_Slice_1.sdps.sdp.01.geo-location.reference-frame.location ( <i>optional</i> ) | Site1.AAA1.ZIP1 | + +# --- Annex G (informative) + +## Revision history + +| Date | Revision | Author | Description | +|------------|----------|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2021/02/28 | v1.00 | Management interface team | V1 release | +| 2021/06/29 | v2.00 | Management interface team | Minor improvements throughout document<br>New additions:<br>Description of management & SDN for fixed access networks - section 8.2<br>IP / Ethernet section 8.4 content created | +| 2021/11/21 | v3.00 | Management interface team | New content in optical access, Grandmaster clock and slicing use case. Clarifications in many places throughout document. | +| 2022/3/26 | v4.00 | Management interface team | New content in Network slicing use case | +| 2022/10/28 | v5.00 | Management interface team | Added chapter 9.3.1 to 9.3.3 and chapter 10 for Network slicing use case | +| 2023/3/13 | v6.00 | Management interface team | Added annex A and changes for section 9.3 uniform transport network model edits | +| 2023/7/07 | v7.00 | Management interface team | ETSI formatting, updates for IETF network slicing based on recent standards work | +| 2024/03/15 | v8.00 | Management interface team | Added informative appendices E and F | +| 2024/07/15 | v9.00 | Management interface team | Added content for coordinated use cases in appendix E | \ No newline at end of file diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/051c9aac289d561fb3b9c5d4742264c6_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/051c9aac289d561fb3b9c5d4742264c6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6d2d012c99320e78205a1e0c0d6e4d799f20f4a3 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/051c9aac289d561fb3b9c5d4742264c6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2226ec3b814d1c3ffad914a1c9a6c630f59faf800c401921b8d69d851e0e6761 +size 4457 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/0848d5c69822ed0a09380bccedd82457_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/0848d5c69822ed0a09380bccedd82457_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c27ab63c5017a2c8216d9494a6219e1e8efd441a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/0848d5c69822ed0a09380bccedd82457_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c359b569576479ec3c51050992080bc3c7e856815099606a419cd812d6fcff25 +size 44931 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/0a6ee8b1e244b412fcbb3b2e9c5bc240_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/0a6ee8b1e244b412fcbb3b2e9c5bc240_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fbbd88b686516d617b731813cb8a3c7922aa23c6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/0a6ee8b1e244b412fcbb3b2e9c5bc240_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:75b9a06eb81e7e96e32a67dba854afb0f31965736c43ef7e5120f5489f658eb1 +size 48892 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/0d92c2d4811f1db703e29abf3a772ed3_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/0d92c2d4811f1db703e29abf3a772ed3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c556beec5d9a284fe09c63569706e9cb88830256 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/0d92c2d4811f1db703e29abf3a772ed3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4264f611218cea4dd0ab5e30b637961dbbf93647c571a727f17da2d260ccc1b5 +size 63006 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/10b534220771f61b797d34083335a033_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/10b534220771f61b797d34083335a033_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..67dfbc24658214c445fec4639b7d5783709bb06f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/10b534220771f61b797d34083335a033_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c90c1e7760c6620647b874390671ec10e684f746f6341fab5926e193d9971946 +size 59230 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/14d8b90a1d52f60336692d4f67f73b9a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/14d8b90a1d52f60336692d4f67f73b9a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..760c44ce7b7b1781702b503575d9749efc1e9818 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/14d8b90a1d52f60336692d4f67f73b9a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3eada98cd658903ee9d7c35e71527f19b11f5aa569b1121d7866c5621963c986 +size 4440 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/25399e39136b914ec555805b3468fd34_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/25399e39136b914ec555805b3468fd34_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d67301d2d0ad90650bdbcade5ef0e5007da3b345 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/25399e39136b914ec555805b3468fd34_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a15b78f3f60adb762254e057c6448089001c7ba2b934c3e85da5118806ea9a58 +size 4536 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/306e8a040aee98b97f117a4980977f1c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/306e8a040aee98b97f117a4980977f1c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cd0c870c5fd83caa9c6e16e383d5245e71b9d3fa --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/306e8a040aee98b97f117a4980977f1c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1df36f5409da6f0af62f569486b0baa03116f751f1fbdaf12bf3af1df1db97aa +size 8161 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/4a376d52119af388f450aca4cfdd193d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/4a376d52119af388f450aca4cfdd193d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..367e6498961a2ebe8051757ddb179a7e38c0f72c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/4a376d52119af388f450aca4cfdd193d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9bad666f7fa6f57adb534ee67f5ef32f605ee897ea11eeb8211161e837964dd6 +size 4442 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/525de5a5dc79680ddba841dac9ee891c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/525de5a5dc79680ddba841dac9ee891c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e06c744b46951c23ddc0a7d60cf38bd98068235d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/525de5a5dc79680ddba841dac9ee891c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84d8f6b8c49f0b772dcc65644a59676f7d0a076052f00f490118f2a673cc5815 +size 4521 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/579d101ab06b4b05ef07594470b9955b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/579d101ab06b4b05ef07594470b9955b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2e9c13f5eb64c4a40225dc9be8aa3488c25f5410 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/579d101ab06b4b05ef07594470b9955b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1842a1fcb4e791a168ae522f8690e7972dae4544ef79bd4de84ac0a443dcdc40 +size 63803 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/6486f47bb0032323835fdbc71ff4a0b0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/6486f47bb0032323835fdbc71ff4a0b0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fa507635418591045ce0ff7331e508b36eed7012 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/6486f47bb0032323835fdbc71ff4a0b0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84dd1f13c7eb3812467975540b65f9d1b3287e2aa00bd96bc2ae7188f9d11459 +size 121427 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/6567859df66d9102817e1d0cbfb88d3b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/6567859df66d9102817e1d0cbfb88d3b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fda4756a5596556de3ca0e263db81ea9416ffc70 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/6567859df66d9102817e1d0cbfb88d3b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b78f0a3ee7dfa5c860075e6a8b35b90ac877cc11d7208d4f0ee436ce85f62b32 +size 22618 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/67d337316e6534290a153c53dad8044b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/67d337316e6534290a153c53dad8044b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a3412f186e335eb0adcf3f6c4fd75113722c017b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/67d337316e6534290a153c53dad8044b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7e008f542d99f2f8a75a2a4fd6f90fbdce317b2472d221b8f0c248562dd2e379 +size 25546 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/67eabecfe07950732768775dd9753cd0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/67eabecfe07950732768775dd9753cd0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1945324367f75dbe46be2511c0789f8d798365e0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/67eabecfe07950732768775dd9753cd0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bf9cdde75a7cc2c5ecec8006729f77ba12ee2f73fae33186ecafd75dba6d12ae +size 4526 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/6cb958362d65ed32dd1a5f6fe0a4a965_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/6cb958362d65ed32dd1a5f6fe0a4a965_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..571c6fb68814c1e4c1b9bdb86415fbd7bada2e2b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/6cb958362d65ed32dd1a5f6fe0a4a965_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6b51858c0e05c448c59610afd712e58b82bdc2dd4bdcfdd9c42ebda491259ba7 +size 103776 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/86ab6bb6e10289814ba291cabf8d2798_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/86ab6bb6e10289814ba291cabf8d2798_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..06a3e25ecd6ae8b2fb70208da149312ca18b1121 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/86ab6bb6e10289814ba291cabf8d2798_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:becbcc23e666f1cf647bff9d4a3453656bfd897635a2ffb9776ad79347421e00 +size 4575 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/88d27ce2c438a3cc1c6a11ddc2ba5824_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/88d27ce2c438a3cc1c6a11ddc2ba5824_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..00eca0a140991c7c20a48b08b3d7b8e29980f937 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/88d27ce2c438a3cc1c6a11ddc2ba5824_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4fdb6776335b8e16a9e707fa0a2fc021ef92839261ab9c5eca25117ec6d49d6b +size 48099 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/8983c35605cf074e2b23b179a8671f2b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/8983c35605cf074e2b23b179a8671f2b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..305187c6d49f524ae9bc2c0e7fb2caa8235421e6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/8983c35605cf074e2b23b179a8671f2b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9f8aa4bbedd5874b65bcced7005360504be4973913536091b4184958c810f588 +size 51215 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/a680d1afaa17f8858741dddaec748092_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/a680d1afaa17f8858741dddaec748092_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..783dbccabfe9ee37fa0b7635997274983a903950 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/a680d1afaa17f8858741dddaec748092_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f540ebe1a26f1c90e129e0d07524ad97686dd59318684fa66dc02dea3e73f3ca +size 139539 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/a8a7791b8e7ed3d0f0cbb3b1685489d3_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/a8a7791b8e7ed3d0f0cbb3b1685489d3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3dcf4bfa46c3ac5de7ca8b7aceebbedccacf8338 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/a8a7791b8e7ed3d0f0cbb3b1685489d3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7eef353e7c02ce218e6b3bfec60401763591bee73598f688def644d92dba3fd0 +size 26953 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ac4bedf643144de4de6f005512c7b895_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ac4bedf643144de4de6f005512c7b895_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..352902a3d69b254f027ad193f033f72e83355515 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ac4bedf643144de4de6f005512c7b895_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:68c699c9b569e11090cdba566efbd90e0c1baa1598ef7bbcb0d26780ff8acb62 +size 140503 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/b2955985f800c56d026e6876d9f194bd_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/b2955985f800c56d026e6876d9f194bd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..180c03cb226af06e687cf29e28ed53f9f7967027 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/b2955985f800c56d026e6876d9f194bd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f71bffa0184dedfe3ecce5f3b034f1ef8e186c803f9d0680d4a2b35116a816e3 +size 4496 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/b89894450b534e46ea14b92afa0601ca_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/b89894450b534e46ea14b92afa0601ca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c1a826a757700194b7d5cd08463a07f72aecb78d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/b89894450b534e46ea14b92afa0601ca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7cb2bbd3032c52683700f816e6242336f3664b3bb493c158cd1397a34ac68676 +size 4567 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/c0314e786fcaafee916d26d38298680c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/c0314e786fcaafee916d26d38298680c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dfa20b311a24ae4dce6ec43951c66a01259999e7 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/c0314e786fcaafee916d26d38298680c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ddde26fd4eb1b611066f59252b92412da1f3af6454c57c062cb70490c63ee22b +size 4540 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ca1a48d1e0465d6fdbf16b5d3dbcc1bc_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ca1a48d1e0465d6fdbf16b5d3dbcc1bc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b4386e80a22e27181a79aeeef47e45742bb511ae --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ca1a48d1e0465d6fdbf16b5d3dbcc1bc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8dbc147154d73e951f728b064ee9a2a70ba20fad281c46df385b39aacece2d76 +size 44142 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/cc33afd7a493a564ad10d2021e3e00cb_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/cc33afd7a493a564ad10d2021e3e00cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0ca0592e2a3403cca611bef52bf776243e32c7f4 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/cc33afd7a493a564ad10d2021e3e00cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d67f19f5a3682c11a212c070591a9fed24306a5273dbd6ae25304a7a9b2a868b +size 4491 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/cd849656b7a58020e6d0624dd6cb78cf_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/cd849656b7a58020e6d0624dd6cb78cf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..da075e45e194d7a89a170e7e2ed4a5d8b5833003 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/cd849656b7a58020e6d0624dd6cb78cf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6ea09bf8b51021b72570bde3bd53d0da49a347b3c973b677fa5d2ea5a377e5be +size 4507 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/cecb22afa8bb5346db92d9dcbcfbdb6d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/cecb22afa8bb5346db92d9dcbcfbdb6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5545e1f517c3bd8d457fa20ba888740d02c04a3d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/cecb22afa8bb5346db92d9dcbcfbdb6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ba7069dacbc70bc0d123c45605afe9bc5a78318f320db2fd14c8e500756b79d6 +size 34128 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d25635c5860743ef13414a5887a8eb46_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d25635c5860743ef13414a5887a8eb46_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7ec20791e86a375d1cb077288d2472e37e05e9c9 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d25635c5860743ef13414a5887a8eb46_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3ff6d6b704bc758856626ca8f6b14c3332417015a40f9fc490f31af1ed1bf17a +size 57238 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d3b05d1f9cc9982be9d24085b0d3fa91_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d3b05d1f9cc9982be9d24085b0d3fa91_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..22399f6c5ccef62e2aea9c3adc1135c37e2120e3 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d3b05d1f9cc9982be9d24085b0d3fa91_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0a2fd0c378d786847f4f0519dcc732cabe69187c3a9ab0d234b8a2b7013d0e9b +size 4507 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d6e77ba812ff8ede90f1f0a589f61674_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d6e77ba812ff8ede90f1f0a589f61674_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5483468a8d53f73e0853a456ab1c2269ce3005cb --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d6e77ba812ff8ede90f1f0a589f61674_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7b2169e2fe416476290b2ab13839f59c11298d75d7a56f6a390644e8bb4c4ffc +size 122846 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d6f89c8c8eb988aed1544a26b9233947_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d6f89c8c8eb988aed1544a26b9233947_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a0e1c8a656f5f537a569bda7ee538b2bfd32b372 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/d6f89c8c8eb988aed1544a26b9233947_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:13c07ed4ee6cacf0cb19f1501fdf2adc6736038fbb22f7bee7be991b19999264 +size 52621 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/dff380f1b4dc929d51d2dcfe92cecc11_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/dff380f1b4dc929d51d2dcfe92cecc11_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3bc9267c14d95cfdd1b0194accaa28a015f9c07d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/dff380f1b4dc929d51d2dcfe92cecc11_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:53fadf1c31dd486608dc7583eb4f22a223eddd37ef6cab91f4756b59a94a7328 +size 4499 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ebeba7d2b5c1d5689122468a47833c28_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ebeba7d2b5c1d5689122468a47833c28_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a2e146c9f8be373f3bc23a72050c7980e11b867b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ebeba7d2b5c1d5689122468a47833c28_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:51f704a160b86cf9e4198e103264d4e32b8e79c601386976214142addd01fdd4 +size 49225 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/f1f0a88cd54e4260ac2f0ef804bf4d0b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/f1f0a88cd54e4260ac2f0ef804bf4d0b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f4976c77576efbd408c760a6141c6f9cc78dbf7d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/f1f0a88cd54e4260ac2f0ef804bf4d0b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:afcf4f0f39c02b1eecda727cdfb84ab027d3c12dde1b344ef2f65a82603992a0 +size 83279 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/fcd9984df443188caee3542aa0dfbdb4_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/fcd9984df443188caee3542aa0dfbdb4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9fd8d2cf49d79c0855922bd1640ae13ec8c91c9d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/fcd9984df443188caee3542aa0dfbdb4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:53c588be72ce053a75b321cfa685b1e3e75f6e26da4a29f1698bd5901372ad01 +size 4534 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ffdcbeea5ca0bf1e55b189f3bb4224de_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ffdcbeea5ca0bf1e55b189f3bb4224de_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..67790ef0b53e901582ff0e1a641042ca5c8e7b92 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/ffdcbeea5ca0bf1e55b189f3bb4224de_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f16331ccb53febcb78007eeb1ac5fcc42019339d63b5392b68d97821466a3cbb +size 37911 diff --git a/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/raw.md b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..be466e9b5343c33a8bfc01ad894241b22e041464 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-REQ-v01.00/raw.md @@ -0,0 +1,1736 @@ + + +# O-RAN Open Xhaul Transport Working Group 9 + +# Xhaul Transport Requirements --- + +**This is a re-published version of the attached final specification.** + +For this re-published version, the prior versions of the IPR Policy will apply, except that the previous requirement for Adopters (as defined in the earlier IPR Policy) to agree to an O-RAN Adopter License Agreement to access and use Final Specifications shall no longer apply or be required for these Final Specifications after 1st July 2022. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material on this site for your personal use, or copy the material on this site for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +# **O-RAN Open Xhaul Transport Working Group 9****Xhaul Transport Requirements** + +Copyright © 2021 by O-RAN ALLIANCE e.V. + +By using, accessing or downloading any part of this O-RAN specification document, including by copying, saving, distributing, displaying or preparing derivatives of, you agree to be and are bound to the terms of the O-RAN Adopter License Agreement contained in Annex ZZZ of this specification. All other rights reserved. + +O-RAN ALLIANCE e.V. +Buschkauler Weg 27, 53347 Alfter, Germany +Register of Associations, Bonn VR 11238 +VAT ID DE321720189 + +| Author | Company | Chapters | +|-------------------------|------------------|--------------------| +| Sumithra Bhojan | AT&T | 7 | +| Lujing Cai | AT&T | 7, 10, 13, Annex A | +| Philippe Chancelou | Orange | 11, Annex C | +| Kamatchi Gopalakrishnan | Juniper Networks | 12 | +| Liuyan Han | China Mobile | 12 | +| Derek Reese | AT&T | 12, 13 | +| Stefano Ruffini | Ericsson | 12 | +| Simon Spraggs | Cisco Systems | 1-6, 8-10, Annex B | +| Krzysztof Szarkowicz | Juniper Networks | 12 | +| Reza Vaez-Ghaemi | Viavi Solutions | 1-7, Coordination | + +# 1 Revision History + +| Date | Revision | Author | Description | +|------------|----------|------------------|-------------------------------------------------------------------------------------| +| 2020/11/11 | V01.00 | Reza Vaez-Ghaemi | Incorporated responses to comments from the WG9 review process ended on Nov 9, 2020 | + +# 2 Contents + +| | | | | +|----|--------|------------------------------------------------------------------|----| +| 1 | 2 | Contents | | +| 2 | 1 | Revision History | 3 | +| 3 | 3 | Scope | 6 | +| 4 | 4 | References | 7 | +| 5 | 5 | Definitions and abbreviations | 10 | +| 6 | 5.1 | Definitions | 10 | +| 7 | 5.2 | Abbreviations | 10 | +| 8 | 6 | Open Xhaul Transport infrastructure | 12 | +| 9 | 6.1 | Xhaul transport network details | 12 | +| 10 | 6.1.1 | 5G services and vertical markets | 12 | +| 11 | 6.1.2 | Network Scale and capacity | 12 | +| 12 | 6.1.3 | 5G RAN Architectures | 12 | +| 13 | 6.1.4 | Network DCs, MEC and NFV | 13 | +| 14 | 6.1.5 | Flexible Xhaul transport infrastructure | 13 | +| 15 | 6.1.6 | Xhaul multi-service capability | 15 | +| 16 | 6.2 | Xhaul Functional Split | 15 | +| 17 | 6.3 | High-level Xhaul Transport requirements | 16 | +| 18 | 7 | Fronthaul | 17 | +| 19 | 7.1 | Fronthaul details | 17 | +| 20 | 7.2 | Fronthaul specific requirements | 18 | +| 21 | 8 | Midhaul | 21 | +| 22 | 8.1 | Midhaul details | 21 | +| 23 | 8.1.1 | O-DU to O-CU communications | 22 | +| 24 | 8.1.2 | Inter O-CU communications | 22 | +| 25 | 8.2 | Midhaul requirements | 24 | +| 26 | 9 | Backhaul | 26 | +| 27 | 9.1 | Backhaul details | 26 | +| 28 | 9.2 | Backhaul transport evolution in 5G | 27 | +| 29 | 9.3 | Backhaul and Midhaul transport requirements | 29 | +| 30 | 10 | Transport network dimensioning for Midhaul and Backhaul | 38 | +| 31 | 10.1 | Transport capacity and radio density with 5G | 38 | +| 32 | 10.2 | Backhaul and Midhaul transport planning | 38 | +| 33 | 10.2.1 | 5G NR peak bandwidth | 38 | +| 34 | 10.2.2 | Site peak data rates | 39 | +| 35 | 10.2.3 | Estimating cell site loads | 41 | +| 36 | 10.2.4 | Transport dimensioning and provisioning for Backhaul and Midhaul | 41 | +| 37 | 10.2.5 | C-RAN Backhaul dimensioning | 44 | +| 38 | 10.2.6 | Midhaul dimension | 44 | +| 39 | 10.3 | Backhaul and Midhaul latency | 45 | +| 40 | 11 | Transport operability | 46 | +| 41 | 11.1 | Operational transport requirements | 46 | +| 42 | 11.1.1 | Transport equipment at antenna site | 46 | +| 43 | 11.1.2 | Dual manage transport equipment at antenna site | 46 | +| 44 | 11.1.3 | Supervision | 46 | +| 45 | 11.1.4 | Rogue behaviour and its mitigation in access transport segment | 47 | +| 46 | 11.1.5 | Transport availability | 47 | +| 47 | 11.2 | Transceiver and port monitoring and identification | 48 | +| 48 | 11.2.1 | Transceiver digital diagnostic monitoring | 48 | +| 49 | 11.2.2 | Transceiver class of operation for bidirectional transmission | 48 | +| 50 | 11.2.3 | Transceiver class of operation for WDM transmission | 48 | +| 51 | 11.2.4 | Port-ID to ease field operation | 49 | +| 52 | 11.2.5 | Eye safety | 49 | + +| | | | | +|----|------|--------------------------------------------------------|----| +| 1 | 11.3 | Power saving and energy efficiency ..... | 49 | +| 2 | 11.4 | Remote monitoring antenna site operation ..... | 50 | +| 3 | 11.5 | Operability requirements ..... | 50 | +| 4 | 12 | Synchronization..... | 52 | +| 5 | 12.1 | Frequency, Phase and Time Accuracy Requirements..... | 52 | +| 6 | 12.2 | Error Budget Allocation Requirements..... | 53 | +| 7 | 12.3 | Synchronization solution requirements..... | 55 | +| 8 | 12.4 | Summary..... | 56 | +| 9 | 13 | Legacy Requirements..... | 59 | +| 10 | | Annex A Fronthaul Bandwidth Calculation ..... | 61 | +| 11 | | Annex B: Slicing in Backhaul and Midhaul..... | 63 | +| 12 | | Annex C: Delay Asymmetry ..... | 67 | +| 13 | | Annex ZZZ : O-RAN Adopter License Agreement ..... | 69 | +| 14 | | Section 1: DEFINITIONS ..... | 69 | +| 15 | | Section 2: COPYRIGHT LICENSE ..... | 69 | +| 16 | | Section 3: FRAND LICENSE ..... | 70 | +| 17 | | Section 4: TERM AND TERMINATION..... | 70 | +| 18 | | Section 5: CONFIDENTIALITY ..... | 71 | +| 19 | | Section 6: INDEMNIFICATION ..... | 71 | +| 20 | | Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY ..... | 71 | +| 21 | | Section 8: ASSIGNMENT ..... | 71 | +| 22 | | Section 9: THIRD-PARTY BENEFICIARY RIGHTS ..... | 72 | +| 23 | | Section 10: BINDING ON AFFILIATES ..... | 72 | +| 24 | | Section 11: GENERAL..... | 72 | +| 25 | | | | +| 26 | | | | +| 27 | | | | + +# 3 Scope + +This document defines the requirements for an Open Xhaul transport infrastructure. As far as possible it tries to make no assumptions about the underlying transport technology, rather define a set of requirements about the overall capabilities of an Open Xhaul transport infrastructure that can support different 5G services, different radio architectures and is multi-service in nature. This document refers to 5G services, but the transport requirements also apply to O-RAN networks deploying 4G services. + +Following introductory sections 1 through 5, section 6 concentrates on a general description of Open Xhaul transport and high-level requirements. The next three sections concentrate on the transport networking requirements needed to support the different radio architectures identified in 5G, namely, Fronthaul, Midhaul and Backhaul. The aim is to provide the reader specific information about the transport infrastructure in order to support different radio splits. Section 11 provides requirement for ease of operability of transport networks. The last two main sections revolve around requirements for synchronization and legacy services. + +This document uses information published by O-RAN, 3GPP, IEEE, ITU-T, IETF, CableLabs, NGMN and several other relevant standard bodies and industry associations. It contains educational, informative, and normative content. + +What is not covered in this document: + +- As stated above, the document makes no assumption about transport technologies to be used. Technology specific architectural considerations shall be covered in other -possibly WG9- documents and will be referenced in this document as soon as published. Examples include DOCSIS, PON, WDM, Ethernet/IP based implementations, as well as, architectures that may deploy Fronthaul gateways, Fronthaul muxes or other types of CPRI/eCPRI aggregation technologies. +- The document doesn't cover the synchronization architectural options. These aspects will be covered in an upcoming WG9 Synchronization Solution document. +- Finally, this document provides no requirements on synchronization requirements at an O-RU output. They are stated in WG4 CUS Specification document [74]. + +# 4 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 15. + +- [1] 3GPP TS 38.472 V15.5.0: "F1 signalling transport (Release 15)". +- [2] IEEE 802.1Q-2018: "IEEE Standard for Local and metropolitan area networks—Bridges and Bridged Networks" +- [3] IETF RFC 2474: "Definition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 Headers" +- [4] IETF RFC 2598: "An Expedited Forwarding PHB" +- [5] IETF RFC 2597: "Assured Forwarding PHB Group" +- [6] IETF RFC 4594: "Configuration Guidelines for DiffServ Service Classes" +- [7] IETF RFC 826: "An Ethernet Address Resolution Protocol -- or -- Converting Network Protocol Addresses" +- [8] IETF RFC 792: "INTERNET CONTROL MESSAGE PROTOCOL" +- [9] IETF RFC 8200: "Internet Protocol, Version 6 (IPv6) Specification" +- [10] IETF RFC 4861: "Neighbor Discovery for IP version 6 (IPv6)" +- [11] IETF RFC 4443: "Internet Control Message Protocol (ICMPv6) for the Internet Protocol Version 6 (IPv6) Specification" +- [12] IETF RFC 6890: "Special-Purpose IP Address Registries" +- [13] IETF RFC 8190: "Updates to the Special-Purpose IP Address Registries" +- [14] IETF RFC 2131: "Dynamic Host Configuration Protocol" +- [15] IETF RFC 4361: "Node-specific Client Identifiers for Dynamic Host Configuration Protocol Version Four (DHCPv4)" +- [16] IETF RFC 3315: "Dynamic Host Configuration Protocol for IPv6 (DHCPv6)" +- [17] IETF RFC 4862: "IPv6 Stateless Address Autoconfiguration" +- [18] IETF RFC 768: "User Datagram Protocol" +- [19] 3GPP TS 29.060 V15.0.0: "GPRS Tunnelling Protocol (GTP) across the Gn and Gp interface (Release 15)" +- [20] 3GPP TS 29.274 V16.1.0: "GPRS Tunnelling Protocol (GTP) across the Gn and Gp interface (Release 15)" +- [21] 3GPP TS 36.422 version 15.1.0: "X2 signalling transport (Release 15)" +- [22] 3GPP TS 36.424 version 15.0.0: "X2 data transport (Release 15)" +- [23] 3GPP TS 38.474 V15.3.0: "F1 data transport (Release 15)". +- [24] 3GPP TS 33.117 V16.2.0: "Catalogue of general security assurance requirements (Release 16)" +- [25] IETF RFC 2119: "Key words for use in RFCs to Indicate Requirement Levels" +- [26] IEEE 802.3-2018: "IEEE Standard for Ethernet" +- [27] IETF RFC 791: "INTERNET PROTOCOL" +- [28] IETF RFC 1918: "Address Allocation for Private Internets" +- [29] IETF RFC 5357: "A Two-Way Active Measurement Protocol (TWAMP)" +- [30] IETF RFC 4656: "A One-way Active Measurement Protocol (OWAMP)" + +- [31] ITU-T G.8013/Y.1731(08/2015): “Operation, administration and maintenance (OAM) functions and mechanisms for Ethernet-based networks” +- [32] IETF RFC 4960. “Stream Control Transmission Protocol” +- [33] 3GPP TS 29.281 V15.6.0: “General Packet Radio System (GPRS) Tunnelling Protocol User Plane (GTPv1-U) (Release 15)” +- [34] IETF RFC 1034: “DOMAIN NAMES - CONCEPTS AND FACILITIES” +- [35] IETF RFC 1035: “DOMAIN NAMES - IMPLEMENTATION AND SPECIFICATION” +- [36] IETF RFC 4210: “Internet X.509 Public Key Infrastructure Certificate Management Protocol (CMP)” +- [37] IETF RFC 6083: “Datagram Transport Layer Security (DTLS) for Stream Control Transmission Protocol (SCTP)” +- [38] 3GPP TS 33.501 V15.6.0: “Security architecture and procedures for 5G system (Release 15)” +- [39] IETF RFC 4301: “Security Architecture for the Internet Protocol” +- [40] 3GPP TS 33.210 V16.2.0: “Network Domain Security (NDS); IP network layer security (Release 16)” +- [41] 3GPP TS 33.310 V16.2.0: “Network Domain Security (NDS); Authentication Framework (AF) (Release 16)” +- [42] 3GPP TS 33.401 V16.0.0: “3GPP System Architecture Evolution (SAE); Security architecture (Release 15)” +- [43] 3GPP TR 33.821 V9.0.0: “Rationale and track of security decisions in Long Term Evolved (LTE) RAN / 3GPP System Architecture Evolution (SAE) (Release 9)” +- [44] IETF RFC 4303: “IP Encapsulating Security Payload (ESP)” +- [45] IETF RFC 8221: “Cryptographic Algorithm Implementation Requirements and Usage Guidance for Encapsulating Security Payload (ESP) and Authentication Header (AH)” +- [46] IETF RFC 7296: “Internet Key Exchange Protocol Version 2 (IKEv2)” +- [47] ETSI GS NFV-INF 005 V1.1.1 (2014-12): Network Functions Virtualisation (NFV); Infrastructure; Network Domain +- [48] 3GPP TS 38.462 V15.5.0: “E1 signalling transport (Release 15)” +- [49] MEF 22.3: “Transport Services for Mobile Networks, January 2018” +- [50] 3GPP TS 29.303 V16.0.0: “Domain Name System Procedures; Stage 3 (Release 16)” +- [51] eCPRI Transport Requirements V1.2, Common Public Radio Interface: Requirements for the eCPRI Transport Network, June 25, 2018. +- [52] IEEE 802.1CMde: Time-Sensitive Networking for Fronthaul Amendment: Enhancements to Fronthaul Profiles to Synchronization, and Synchronization Standards Networking for Fronthaul, —Support New Fronthaul Interface, July 26, 2019 +- [53] IEEE 1914.1™ D3.0, Draft Fronthaul Transport Networks, November 2018. +- [54] 3GPP TS 38.422 version 15.0.0 Release 15: Xn general aspects and principles +- [55] GSMA: “5G Implementation Guidelines: NSA Options” +- [56] NGMN: “NGMN Overview on 5G functional decomposition” +- [57] ITU-T GSTR-TN5G: “Transport Network support of IMT-2020-TG” +- [58] 3GPP 38.401: “NG-RAN; Architectural description” +- [59] O-RAN: “WG-4 Inter-Operability Testing” +- [60] O-RAN Open F1/W1/E1/X2/Xn Interfaces Working Group “Transport Specification” + +- [61] NGMN “5G RAN CU-DU network architecture, transport options and dimensioning, version 1.0 12 April 2019)” +- [62] 5G Transport Slice Connectivity Interface – draft-rokui-5g-transport-slice-00 +- [63] 3GPP R3-162102 TSG-RAN Working Group 3 Meeting #93-bis CU-DU split: Refinement for Annex A (Transport network and RAN internal functional split) +- [64] 3GPP TS 38.101: “NR, User Equipment (UE) radio transmission and reception” +- [65] 3GPP TS 38.300: “NR Overall description” +- [66] GSMA: “5G Implementation Guidelines v2” +- [67] 3GPP TS 23.501 v6.4.0(2020-03): “System Architecture for 5G” +- [68] MEF 61.1: “IP Service attributes” +- [69] MEF 10.3: “Ethernet Service attributes” +- [70] MEF 6.2: “EVC service definition” +- [71] 3GPP TS38.306: “NR; User equipment (UE) radio access capabilities” +- [72] NGMN “Guidelines for LTE Backhaul estimations” +- [73] ITU-R M.2083: “IMT Vision – framework and overall objectives of the future development of IMT for 2020 and beyond”. +- [74] O-RAN Fronthaul Working Group, “Control, User and Synchronization Plane Specification”, v03.00 (04/2020) +- [75] 3GPP TS36.104, version 16.4.0, 01/2020, “Evolved Universal Terrestrial Radio Access (E-UTRA) Base Station (BS) and radio transmission and reception”. +- [76] 3GPP TS38.104, version 16.2.0, 01/2020, “NR Base Station (BS) and radio transmission and reception”. +- [77] ITU-T G.8271.1, 03/2020, “Network limits for time synchronization in packet networks with full timing support from the network” +- [78] ITU-T G.8272 Amendment 1, 03/2020, “Timing characteristics of primary reference time clocks” +- [79] ITU-T G.8272.1, Amendment 2, 08/2019, “Timing characteristics of enhanced primary reference time clocks” +- [80] ITU-T G.8275.1, 03/2020, “Precision time protocol telecom profile for phase/time synchronization with full timing support from the network “ +- [81] ITU-T G.8273.2 Amendment, 03/2020, “Timing characteristics of telecom boundary clocks and telecom time slave clocks” +- [82] ITU-T G.8272/Y.1367, 11/2018. “Timing characteristics of primary reference time clocks” +- [83] 3GPP TS38.801, version 14.0.0, 03/2017, “Study on new radio access technology: Radio access architecture and interfaces” +- [84] NGMN “Overview on 5G RAN function decomposition” +- [85] 3GPP TR22.804 v16.2.0 (2018-12), “Study on communications for automation in vertical domains” + +# 5 Definitions and abbreviations + +## 5.1 Definitions + +The key words "**SHALL**", "**SHALL NOT**", "**SHOULD**", "**SHOULD NOT**", "**MAY**", and "**OPTIONAL**" in this document are to be interpreted as described in IETF RFC 2119 [25]. All key words must be in upper case, bold text. + +Items that are **REQUIRED** (contain the words **SHALL** or **SHALL NOT**) will be labelled as **[Rx]** for required. Items that are **RECOMMENDED** (contain the words **SHOULD** or **SHOULD NOT**) will be labelled as **[Dx]** for desirable. Items that are **OPTIONAL** (contain the words **MAY** or **OPTIONAL**) will be labelled as **[Ox]** for optional. + +Items, if supported, are not meant to be active at all times, but should be available for use. Their state (active or not active) should be based on configuration. + +## 5.2 Abbreviations + +Abbreviations defined in this document take precedence over the definition of 3GPP + +| | | | | +|------------------|------------------------------------------|-------|-----------------------------------------------------------------| +| AF | Application Function | ITU-T | International Telecom Union-Telecom | +| AMF | Access and Mobility Management Function | LAN | Local Area Network | +| AN | Access Node | LLS | Lower Layer Split | +| ARP | Address Resolution Protocol | LTE | Long Term Evolution | +| ABW | Antenna Bandwidth | MAC | Medium Access Layer | +| BBU | Baseband Unit | MBSFN | Multimedia Broadcast multicast service Single Frequency Network | +| BH | Backhaul | MPLS | Multi-Protocol Label Switching | +| BiDi | Bidirectional | MIMO | Multiple Inputs Multiple Outputs | +| BS | Base Station | MNO | Mobile Network Operator | +| BW | Bandwidth | MRTD | Maximum Receive Time Difference | +| CAPEX | Capital Expense | NGMN | Next Generation Mobile Network | +| CBS | Committed Burst Size | NR | New Radio | +| CFP | Common Form factor Pluggable | NSA | Non-Stand Alone | +| CIR | Committed Information Rate | NSSI | Subnet Networking Slices Instance | +| CN | Core Network | OAM | Operation Administration Maintenance | +| CoMP | Coordinated Multipoint | O-CU | O-RAN Central Unit | +| CP | Control Plane | O-DU | O-RAN Distributed Unit | +| CPRI | Common Public Radio Interface | OPEX | Operation Expense | +| CU | Central Unit | O-RU | O-RAN Radio Unit | +| DC | Data Center | PCF | Policy Control Function | +| DL | Downlink | PDCCP | Packet Data Convergence Protocol | +| DN | Data Network | ppb | Parts per billion | +| DHCP | Dynamic Host Configuration Protocol | PRB | Physical Resource Block | +| DSCP | Differentiated Services Codepoint | PRTC | Primary Reference Telecom Clock | +| dTE <sub>H</sub> | Dynamic Time Error High | PTP | Precision Time Protocol | +| dTE <sub>L</sub> | Dynamic Time Error Low | OFDM | Orthogonal Frequency Division Multiplexing | +| DU | Distributed Unit | QAM | Quadrature Amplitude Modulation | +| eCPRI | evolved Common Public Radio Interface | QoS | Quality of Service | +| eMBB | enhanced Mobile Broadband | QSFP | Quad SFP | +| eNB | Evolved NodeB | RB | Resource Block | +| EP | Ethernet Private | RRH | Remote Radio Head | +| EPC | Evolved Packet Core | RU | Radio Unit | +| EPL | Ethernet Private Line | SCS | Sub Carrier Spacing | +| ePRC | Enhanced Primary Reference Clock | SCTP | Stream Control Transmission Protocol | +| ePRTC | Enhanced Primary Reference Telecom Clock | SFF | Small Form Factor | +| E-UTRA | evolved UMTS Terrestrial Radio Access | SFP | Small Form factor Pluggable | + +| | | | | +|------|------------------------------------|-------|------------------------------------------------| +| EVP | Ethernet Virtual Private | SLA | Service Level Agreement | +| EVPL | Ethernet Virtual Private Line | TAE | Time Alignment Error | +| FDD | Frequency Division Duplex | T-BC | Telecom Boundary Clock | +| FFO | Fractional Frequency Offset | TDD | Time Division Duplex | +| FFS | For Further Study | TE | Time Error (in the context of synchronization) | +| FH | Fronthaul | T-GM | Telecom Ground Master | +| FLR | Frame Loss Ratio | TN | Transport Node | +| FR1 | Frequency Range 1 | TNE | Transport Network Equipment | +| FR2 | Frequency Range 2 | T-TSC | Telecom Time Slave Clock | +| FTTH | Fiber To The Home | TX | Transmit | +| gNB | gNodeB | UDP | User Datagram Protocol | +| GNSS | Global Navigation Satellite System | UE | User equipment | +| GPRS | General Packet Radio Service | UL | Uplink | +| GTP | GPRS Tunnelling Protocol | UNI | Universal Network Interface | +| ICMP | Internet Control Message Protocol | UNI-C | UNI-Customer edge | +| IoT | Internet of Things | UPF | User Plane Function | +| IP | Internet Protocol | URLLC | Ultra Reliable Low Latency Communication | +| IQ | In phase Quadrature | VPN | Virtual Private Network | + +1 +2 +3 + +# 6 Open Xhaul Transport infrastructure + +This section provides a definition of Open Xhaul transport, some of the key characteristics and high-level requirements associated with Open Xhaul transport. + +## 6.1 Xhaul transport network details + +At the highest-level the Open Xhaul transport network provides the connectivity from the Radio Access Network (RAN) to the mobile packet core, which subsequently makes the connection to the application function. These could reside in a public network infrastructure, such as the Internet, a walled garden or a completely private network. For details of future developments envisaged in services / spectrum and timelines please see the “International Mobile Telecommunications (IMT) 2020 and beyond” [73]. + +Below are some of the key considerations + +### 6.1.1 5G services and vertical markets + +5G networks are expected to enable a new range of services that can be categorized in three classes: + +- enhanced Mobile Broadband (eMBB) +- Ultra Reliable Low Latency Communications (URLLC) +- massive Machine Type Communications (mMTC) + +These services will drive the need for new or enhanced classes of RAN and transport networks. + +### 6.1.2 Network Scale and capacity + +Whereas eMBB services demand more capacity in transport networks, URLLC applications will pose new challenges for the design of Xhaul networks in terms of low latency and increased reliability. Finally, mMTC necessitate a network that can efficiently manage huge number of devices such as intelligent devices in utility meters or house appliances. + +### 6.1.3 5G RAN Architectures + +As illustrated in Figure 1, in a traditional D-RAN (distributed RAN) architecture, the O-DU and O-CU are integrated as a BBU, collocated with the O-RU (Radio) at cell site. When evolving to the C-RAN (centralized RAN) architecture, the O-CU, which contains the higher layer of the RAN processing stacks, is centralized in a Hub. Depending on Operator’s deployment needs, the O-DU may remain at cell site, or be centralized. The Xhaul transport (Fronthaul, Midhaul, and Backhaul) serve as connections among the 3GPP RAN and core components. Transport Network Equipment (TNE) represents the transport functions necessary in Xhaul networks. Specifics of TE are outside of the scope of this document and will be covered in WG9 solution documents: + +D-RAN: + +(O-RU+O-DU+O-CU) ← Backhaul → (5GC) + +C-RAN: + +(O-RU) ← Fronthaul → (O-DU+O-CU) ← Backhaul → (5GC) + +(O-RU) ← Fronthaul → (O-DU) ← Midhaul → (O-CU) ← Backhaul → (5GC) + +(O-RU+O-DU) $\leftarrow$ Midhaul $\rightarrow$ (O-CU) $\leftarrow$ Backhaul $\rightarrow$ (5GC) + +The X2/Xn interfaces that provide logical connection between O-CUs (or to LTE eNBs) are also depicted in Figure 1 to support the inter site coordination such as EN-DC. + +![Figure 1: RAN reference architecture diagram showing four scenarios: Centralized RAN Scenario 1, Centralized RAN Scenario 2, Centralized RAN Scenario 3, and Distributed RAN. The diagram illustrates the flow of data and control between O-RU, O-DU, O-CU, and TNE components, connected via Fronthaul (eCPRI), Midhaul (F1), and Backhaul (N2, N3) interfaces. A CRAN-HUB is shown in Scenario 1, and a 5GC cloud is shown in Scenario 2.](6cb958362d65ed32dd1a5f6fe0a4a965_img.jpg) + +The diagram illustrates four RAN architectures: + +- Centralized RAN Scenario 1:** Shows two O-RU/TNE blocks connected to a CRAN-HUB. The CRAN-HUB contains O-DU and O-CU/TNE blocks. Connections include Fronthaul eCPRI, X2 (to LTE eNB), and Xn (between O-CUs). +- Centralized RAN Scenario 2:** Shows one O-RU/TNE block connected to O-DU/TNE, which is then connected to O-CU/TNE. The O-CU/TNE is connected to the 5GC via Backhaul N2, N3. +- Centralized RAN Scenario 3:** Shows one O-RU/TNE block connected to O-DU/TNE, which is then connected to O-CU/TNE. The O-CU/TNE is connected to the 5GC via Backhaul N2, N3. +- Distributed RAN:** Shows one O-RU/TNE block connected to O-DU/TNE, which is then connected to O-CU/TNE. The O-CU/TNE is connected to the 5GC via Backhaul N2, N3. + +Figure 1: RAN reference architecture diagram showing four scenarios: Centralized RAN Scenario 1, Centralized RAN Scenario 2, Centralized RAN Scenario 3, and Distributed RAN. The diagram illustrates the flow of data and control between O-RU, O-DU, O-CU, and TNE components, connected via Fronthaul (eCPRI), Midhaul (F1), and Backhaul (N2, N3) interfaces. A CRAN-HUB is shown in Scenario 1, and a 5GC cloud is shown in Scenario 2. + +Figure 1: RAN reference architecture + +### 6.1.4 Network DCs, MEC and NFV + +Beyond the abovementioned evolution of wireless access networks with D-RAN and C-RAN, wireless operators started to take advantage of Network Function Virtualization NFV technologies to scale and control the CAPEX. Introduction of 5G creates new opportunities to use these technologies to scale functions and manage low latency in radio access networks. + +### 6.1.5 Flexible Xhaul transport infrastructure + +As outlined 5G defines different services and RAN architectures. Figure 2 is adapted from NGMN [56] and illustrates how different RAN components may be placed in different locations within the + +same Mobile Network Operator's (MNO) infrastructure to meet the delay and reliability requirements of a 5G service or vertical market. + +![Diagram showing CU, DU, UPF, MEC placement for ultra-low latency (approx. max 1ms RTT)*. The diagram illustrates a network architecture where RU (Radio Units) are connected to DU (Distributed Units) and UPF (User Plane Functions) at the edge. The DU and UPF are co-located with MEC (Multi-access Edge Computing) at the edge. The network is composed of 5G small cells and mm-wave. The architecture is divided into Tier 1 Site, Tier 2 Site, and Tier 3 Site, connected to External networks.](10b534220771f61b797d34083335a033_img.jpg) + +CU, DU, UPF MEC placement for ultra-low latency (approx. max 1ms RTT)\* + +Diagram showing CU, DU, UPF, MEC placement for ultra-low latency (approx. max 1ms RTT)\*. The diagram illustrates a network architecture where RU (Radio Units) are connected to DU (Distributed Units) and UPF (User Plane Functions) at the edge. The DU and UPF are co-located with MEC (Multi-access Edge Computing) at the edge. The network is composed of 5G small cells and mm-wave. The architecture is divided into Tier 1 Site, Tier 2 Site, and Tier 3 Site, connected to External networks. + +![Diagram showing CU, DU, UPF, MEC placement for very low latency (approx. max 5ms RTT)*. The diagram illustrates a network architecture where RU (Radio Units) are connected to DU (Distributed Units) at the edge. The DU is co-located with MEC (Multi-access Edge Computing) at the edge. The network is composed of 5G small cells and mm-wave. The architecture is divided into Tier 1 Site, Tier 2 Site, and Tier 3 Site, connected to External networks.](579d101ab06b4b05ef07594470b9955b_img.jpg) + +CU, DU, UPF, MEC placement for very low latency (approx. max 5ms RTT)\* + +Diagram showing CU, DU, UPF, MEC placement for very low latency (approx. max 5ms RTT)\*. The diagram illustrates a network architecture where RU (Radio Units) are connected to DU (Distributed Units) at the edge. The DU is co-located with MEC (Multi-access Edge Computing) at the edge. The network is composed of 5G small cells and mm-wave. The architecture is divided into Tier 1 Site, Tier 2 Site, and Tier 3 Site, connected to External networks. + +![Diagram showing CU, DU, UPF placement for low latency (approx. max 10ms RTT)*. The diagram illustrates a network architecture where RU (Radio Units) are connected to DU (Distributed Units) at the edge. The DU is co-located with MEC (Multi-access Edge Computing) at the edge. The network is composed of 5G small cells and mm-wave. The architecture is divided into Tier 1 Site, Tier 2 Site, and Tier 3 Site, connected to External networks.](0d92c2d4811f1db703e29abf3a772ed3_img.jpg) + +CU DU UPF placement for low latency (approx. max 10ms RTT)\* + +Diagram showing CU, DU, UPF placement for low latency (approx. max 10ms RTT)\*. The diagram illustrates a network architecture where RU (Radio Units) are connected to DU (Distributed Units) at the edge. The DU is co-located with MEC (Multi-access Edge Computing) at the edge. The network is composed of 5G small cells and mm-wave. The architecture is divided into Tier 1 Site, Tier 2 Site, and Tier 3 Site, connected to External networks. + +Figure 2: End to end Xhaul transport – adapted from text and diagrams in “NGMN: Overview on 5G RAN Function Decomposition” [84] + +These different RAN deployment models impact on where the Fronthaul, Midhaul and Backhaul overlay the Xhaul transport infrastructure or even if they are all required. Beyond these deployment models, the choice of radio technology/spectrum can impact the architectural split. Low-/mid-/high band radios may require different choice of functional split or Fronthaul (CPRI/eCPRI) technology. The number of antenna ports/layers (spatial multiplexing) is another factor to be considered. + +Ideally the Xhaul transport infrastructure and its design need to be flexible enough to accommodate Backhaul, Midhaul and Fronthaul and even the N6 portions of the 5G infrastructure running in the same part of the physical infrastructure. There will be exceptions to this requirement, for example some MNOs may wish to treat the transport infrastructure supporting the Fronthaul in isolation to the Midhaul and Backhaul but given the similarities and potential overlap between Backhaul/Midhaul/N6 (GiLAN) the Xhaul transport infrastructure must be able to accommodate all these capabilities running in the same portion of the physical transport infrastructure. + +### 6.1.6 Xhaul multi-service capability + +NGMN identifies the need for X-haul transport to be multi-service capable. Depending on the type of service provider the following capabilities MAY need to be supported on the X-haul transport infrastructure: + +- Non-stand Alone (NSA) and Stand-Alone deployment of 5G wireless services including eMBB, mMTC and URLLC defined by 3GPP +- Mobile vertical market solutions +- Legacy 2G/3G/4G wireless services +- Enterprise services +- Residential broadband services +- Data center interconnection + +This paper focuses on mobile deployment cases as listed in the first three bullets above. + +## 6.2 Xhaul Functional Split + +The introduction of 5G services necessitates a new look at the distribution of functions between 4G BBU and RRH (Figure 3). 4G BBU hosts the majority of functional elements with the exception of RF functions. Also known as option 8, CPRI technology provides a simple synchronous interface that allows for a low-cost design of the RRH. It also permits the introduction of advanced mobility functions such as carrier aggregation and CoMP. This simplicity comes at a cost; the CPRI interface transports time domain IQ data whose bandwidth is proportional to the bandwidth of the baseband signal and the number of antennas or more generally the number of spatial streams. Higher bandwidth and massive MIMO requirements of 5G cause an explosive growth of this interface option. + +A review of the functional split options (Figure 3) led to several new options (Options 1 through 7) that can be theoretically considered for solving the challenges raised by emerging 5G services. These options were ultimately narrowed down to three prominent options 2, 6 and 7. + +![Figure 3: Functional Split Options [83]. The diagram illustrates eight functional split options (Option 1 to Option 8) between a base station (BS) and a radio unit (RU). The BS side components from left to right are RRC, PDCP, High-RLC, Low-RLC, High-MAC, Low-MAC, High-PHY, Low-PHY, and RF. The RU side components from left to right are RRC, PDCP, High-RLC, Low-RLC, High-MAC, Low-MAC, High-PHY, Low-PHY, and RF. Red vertical arrows indicate the split points between these layers. Option 1 is at the RRC/PDCP boundary. Option 2 is at the PDCP/High-RLC boundary. Option 3 is at the High-RLC/Low-RLC boundary. Option 4 is at the Low-RLC/High-MAC boundary. Option 5 is at the High-MAC/Low-MAC boundary. Option 6 is at the Low-MAC/High-PHY boundary. Option 7 is at the High-PHY/Low-PHY boundary. Option 8 is at the Low-PHY/RF boundary. Data flows are shown entering and leaving the RRC and PDCP layers on both sides.](ca1a48d1e0465d6fdbf16b5d3dbcc1bc_img.jpg) + +Figure 3: Functional Split Options [83]. The diagram illustrates eight functional split options (Option 1 to Option 8) between a base station (BS) and a radio unit (RU). The BS side components from left to right are RRC, PDCP, High-RLC, Low-RLC, High-MAC, Low-MAC, High-PHY, Low-PHY, and RF. The RU side components from left to right are RRC, PDCP, High-RLC, Low-RLC, High-MAC, Low-MAC, High-PHY, Low-PHY, and RF. Red vertical arrows indicate the split points between these layers. Option 1 is at the RRC/PDCP boundary. Option 2 is at the PDCP/High-RLC boundary. Option 3 is at the High-RLC/Low-RLC boundary. Option 4 is at the Low-RLC/High-MAC boundary. Option 5 is at the High-MAC/Low-MAC boundary. Option 6 is at the Low-MAC/High-PHY boundary. Option 7 is at the High-PHY/Low-PHY boundary. Option 8 is at the Low-PHY/RF boundary. Data flows are shown entering and leaving the RRC and PDCP layers on both sides. + +**Figure 3: Functional Split Options [83]** + +Furthermore, the option 7 also presents different choices in terms of splitting the functions of the PHY layer such as options 7-1, 7-2x, and 7-3 for the Fronthaul interface. This document only focuses on option 7-2x (Figure 4) as the interface for open Fronthaul chosen by O-RAN. However, the document also considers the option 8 for the definition of Fronthaul transport requirement as this interface is widely used in 4G networks and will be presented in future networks not only for 4G services, but also as an option for carrying low bandwidth 5G services. + +## 6.3 High-level Xhaul Transport requirements + +**[R1]: MUST** support the mandatory transport capabilities outlined by WG5 in the “O-RAN Open F1/W1/E1/X2/Xn Interfaces working group transport specification”. [60] + +**[R2]: MUST** support the mandatory transport capabilities outlined by WG4 Open Fronthaul Interfaces Workgroup [74]. + +**[R3]:** Mobile components reside in the WAN and the DC. It **MUST** be possible to build L2 and L3 services where mobile components reside in both domains + +**[R4]: MAY** need to be multiservice in nature. Refer to 6.1.6 for examples of the type of services that may need to be supported on the Xhaul transport network + +**[R5]: SHOULD** support flexible placement of front / mid / Backhaul / N6 on Xhaul transport. + +**[R6]: MUST** support flexible placement of Mid/Backhaul / N6 on Xhaul transport. + +**[R7]: MUST** support L2 and L3 Virtual Private Networks (VPNs). + +**[R8]: MUST** support multi-point VPNs. + +**[R9]: MUST** support point to point VPNs. + +**[R10]: MUST** support 5G network slicing. + +# 7 Fronthaul + +Fronthaul in O-RAN is defined as the connectivity in the RAN infrastructure between the Distributed Unit (O-DU) and Radio Unit (O-RU). + +## 7.1 Fronthaul details + +As explained in section 6.2, the herein presented Fronthaul requirements focus on split options 7-2x, as shown in Figure 4 [74]. Option 8 will be addressed in chapter 13. + +![Figure 4: O-RAN WG4 functional split 7-2x. The diagram shows the functional split between O-DU and O-RU across the O-RAN FH interface. O-DU blocks include Scrambling, Modulation, Layer Mapping, Precoding (bypass mode possible), RE Mapping, and IQ Compression. O-RU blocks include IQ Decompression, Precoding, Digital Beamforming, iFFT and CP addition, Digital to Analog, and Analog Beamforming. Two O-RU categories are detailed: O-RU Category A (Non-precoding, no precoding in radio, optional digital/analog beamforming) and O-RU Category B (Precoding supported, modulation compression, optional digital/analog beamforming). A note states that dotted blocks are not mandatory for all O-RU categories.](6486f47bb0032323835fdbc71ff4a0b0_img.jpg) + +Processing blocks with dotted blocks are not mandatory for all O-RU categories. Precoding operation for certain O-RU categories can be done within the O-RU and in this case precoding in O-DU can be bypassed. + +**O-DU** + +- Scrambling +- Modulation +- Layer Mapping +- Precoding (bypass mode possible) +- RE Mapping +- IQ Compression + +**O-RAN FH** + +**O-RU** + +- IQ Decompression +- Precoding +- Digital Beamforming +- iFFT and CP addition +- Digital to Analog +- Analog Beamforming + +**O-RU Category A** + +- Non-precoding O-RAN Radio Unit. Precoding in radio is not supported. +- Digital and Analog beamforming optional + +**O-RU Category B** + +- Precoding O-RAN Radio Unit. Precoding in radio is supported. +- Allows support for modulation compression. +- Digital and Analog beamforming optional + +Figure 4: O-RAN WG4 functional split 7-2x. The diagram shows the functional split between O-DU and O-RU across the O-RAN FH interface. O-DU blocks include Scrambling, Modulation, Layer Mapping, Precoding (bypass mode possible), RE Mapping, and IQ Compression. O-RU blocks include IQ Decompression, Precoding, Digital Beamforming, iFFT and CP addition, Digital to Analog, and Analog Beamforming. Two O-RU categories are detailed: O-RU Category A (Non-precoding, no precoding in radio, optional digital/analog beamforming) and O-RU Category B (Precoding supported, modulation compression, optional digital/analog beamforming). A note states that dotted blocks are not mandatory for all O-RU categories. + +**Figure 4: O-RAN WG4 functional split 7-2x (Figure 2-2 in [74])** + +The use cases revolve around 4G/5G mobility services and URLLC. The presented requirements take advantage of documents already available by other standard bodies such CPRI (eCPRI Transport Requirements; [51]), IEEE 802.1CMde [52], and IEEE 1914.1 [53]. + +## 7.2 Fronthaul specific requirements + +| Category | Comments | +|----------------------------------------|----------------------------------------------------| +| Interfaces | O-RAN 7.2x, 1914.3, eCPRI, CPRI, | +| Protocols | O-RAN 7.2x: Ethernet VLAN based or IP/UDP | +| Logical connectivity requirements | | +| Bandwidth per O-RU and O-DU | Listed in this chapter below | +| Transport delay (one way) O-RU to O-DU | Listed in this chapter below | +| Transport delay asymmetry | Annex C (For Further Study) | +| Synchronization / timing requirements | Listed in synchronization chapter of this document | + +**Table 1: High level Fronthaul requirements** + +The primary reference for Frame Loss Ratio and Latency proposed in this document is the eCPRI Transport Requirement V1.2 [51]. IEEE 802.1CMde [52] also refers to the eCPRI Transport Requirements V1.2 for latency and frame loss ratio, and therefore is not referenced for the purpose of latency and frame loss ratio requirements in this document. Further information on delay parameters can be found in WG4 CUS specification, Annex B [74]. + +IEEE 1914.1 [53] uses a different terminology for the identification of Fronthaul (NGFI-I) and Midhaul (NGFI-II). It does not include any requirements on frame loss ratio. However, it provides a table for latency requirements that distinguishes the requirements by different use cases. While there is some overlap with the limits provided in eCPRI Transport Requirements document, there are also some differences. To avoid any confusion, we are not presenting the IEEE 1914.1 requirements in this document and are proposing that it only refers to eCPRI Transport Requirement V1.2 document for latency. + +The Frame Loss Ratio and Latency requirements are summarized in Table 2 and Table 3, respectively. + +| CoS Name | Example use | Maxim One-way Frame Loss Ratio Performance | +|----------|-------------------------------------|--------------------------------------------| +| High | User Plane (fast) | $10^{-7}$ | +| Medium | User Plane (slow), C&M Plane (fast) | $10^{-7}$ | +| Low | C&M Plane | $10^{-6}$ | + +**Table 2: Frame loss ratio requirements** + +| Latency Class | Max. One-way Frame Delay Performance | Use case | +|---------------------|--------------------------------------|----------------------------------------------------------| +| High25 | 25 $\mu$ s | Ultra-low latency performance | +| High75 <sup>1</sup> | 75 $\mu$ s | For full NR performance with fiber lengths in 10km range | + +| | | | +|---------|--------------------------------------|--------------------------------------------------------------| +| High100 | 100 $\mu$ s | For standard NR performance with fiber lengths in 10km range | +| High200 | 200 $\mu$ s | For installations with fiber lengths in 30km range | +| High500 | 500 $\mu$ s | Large latency installations > 30 km | +| Medium | User Plane (slow) & C&M Plane (fast) | 1 ms | +| Low | C&M Plane | 100 ms | + +<sup>1</sup>. New requirement category added based on deployment needs. + +**Table 3: One-way Delay requirements** + +Fronthaul bandwidth is dimensioned per cell site, where a number of carriers are deployed at different frequency bands (Low/mid bands in Sub 6 and mm wave in high band), and at different sectors. The Fronthaul bandwidth for a cell site depends on following key parameters + +- Number of sectors +- Radio channel bandwidth of each carrier +- MIMO order of each carrier + +Various sizes of site configuration may be considered for the eCPRI Fronthaul traffic: + +- Small: single sector, carriers in either mmWave or Sub 6 with low MIMO order +- Medium: multiple sectors, carriers in both Sub 6 and mmWave with medium MIMO order +- Large: multiple sectors, carriers in both mmWave and Sub 6 band with Massive MIMO + +Table 4 provides "typical" peak Fronthaul bandwidth "cases" in such site configurations: + +| | Number of sectors | Sub6 | | | | mmWave | | | | Total FH BW (Gbps) | +|--------|-------------------|------------------------------|-------------|------------------------|---------------------------|-----------------|-------------|-----------|--------------|--------------------| +| | | Total CBW <sup>1</sup> (MHz) | MIMO layers | ABW <sup>2</sup> (MHz) | FH BW <sup>3</sup> (Gbps) | Total CBW (MHz) | MIMO layers | ABW (MHz) | FH BW (Gbps) | | +| Small | 1 | | | | 0 | 400 | 2 | 800 | 15 | 15 | +| Medium | 3 | 100 | 4 | 1200 | 23 | 400 | 4 | 4800 | 87 | 110 | +| Large | 3 | 100 | 16 | 4800 | 90 | 800 | 4 | 9600 | 175 | 265 | + +1. CBW: Aggregated Channel Bandwidth of all carriers in a sector + +2. ABW: Antenna Bandwidth = number of sectors X number MIMO layers X CBW + +3. FH BW: Fronthaul Bandwidth for functional split 7-2x (transport protocol overhead not included) + +**Table 4: Fronthaul Bandwidth Reference for eCPRI traffic** + +The FH BW in Table 4 is calculated for functional split 7-2x and block floating point compression specified in O-RAN WG 4 CUS plane specification [74]. The formula used for the calculation is given as follows: + +$$\text{FH BW} = 2 \times 10^{-9} (1 + c) \frac{v_{\text{layer}} N_{\text{PRB}} (12 N_{\text{mantissa}} + N_{\text{exponent}})}{T_s^{\mu}} \text{ (Gbps)}$$ + +Where + +- $v_{layer}$ is the maximum number of supported layers +- $N_{PRB}$ is the maximum RB allocation for a given channel bandwidth and numerology $\mu$ . +- $N_{mantissa}$ is the number of mantissa bits. $N_{mantissa} = 9$ used in Table 4. +- $N_{exponent}$ is the number of the exponent bits. $N_{exponent} = 4$ used in Table 4. +- $T_s^\mu$ is the average OFDM symbol duration in a subframe for a given numerology, i.e., + +$$T_s^\mu = \frac{10^{-3}}{14 \times 2^\mu} \text{ (second)}$$ +- $c$ is the overhead from the control-plane. For downlink, $c \approx 10\%$ and for uplink $c \approx 0$ , as the control-plane is primarily the downlink traffic in O-RAN specification[74]. The overhead may also take different value depending on vendor specific implementation. + +The relation of $N_{PRB}$ to the channel bandwidth and numerology is defined in 3GPP specification [64] that applies to both FDD and TDD. There is no need for any additional scaling by downlink/uplink ratio for TDD because full $N_{PRB}$ is always made available at the time of transmission in one direction (downlink or uplink). + +The Fronthaul bandwidth calculation equation does not include the protocol encapsulation overhead (e.g., eCPRI header, Ethernet header, and IP header, etc.). At an assumption of average packet size equal to 1000, an additional 3.6% overhead needs be added for L2 Ethernet Encapsulation, and 6.4% for L3 IPv4 Encapsulation. + +Note that the Fronthaul traffic from the 7-2x Lower Layer Split is user data dependent. The actual real time Fronthaul bandwidth is expected lower than its peak depending on traffic payload in the deployment. Hence certain level of over subscription to transport network with Fronthaul statistical multiplexing is allowed at operator's decision on the cell site dimensioning, user traffic profiling, and reliability requirement. More accurate calculation of such use of the Fronthaul transport is complex and is for further study. + +Examples of the site carrier configuration related to the Fronthaul bandwidth calculation are provided in Annex A, together with some possible eCPRI or CPRI interface configurations associated with the carriers. + +# 8 Midhaul + +There are many similarities between Midhaul and Backhaul components of a 5G RAN infrastructure and the transport infrastructure needed to support it. In order to avoid duplication this document has dedicated chapters covering Midhaul and Backhaul. These contain descriptions of the component and a requirements table. For requirements that are common for both Midhaul and Backhaul they are held in the Backhaul requirements section (see 9.3). There is also a common chapter (chapter 0) dedicated to dimensioning the transport network. + +## 8.1 Midhaul details + +The Midhaul network is a logical portion of the transport network that supports C-RAN architectures where there is a “High level Split” (HLS) or split 2 in the 5G Radio architecture which implies the O-DU and O-CU are split into independent components. It facilitates: + +- 1) O-DU and O-CUs communication and supports the transport of the 3GPP F1/W1/E1 interfaces. In scenarios where the O-DU and O-CU are a combined entity then these interfaces are not exposed, and the transport network does not have a Midhaul component. +- 2) Inter O-CU communication and supports the transport of the 3GPP Xn interface. In scenarios where the MNO has not implemented a split O-DU and O-CU RAN architecture then these interfaces need to be supported in the Backhaul network. + +Figure 5 illustrates RAN architectures where a Midhaul or HLS is present. + +![Figure 5: RAN architectures where a Midhaul transport is required. The diagram shows two network topologies. The top topology shows an O-RU connected to an O-DU via O-RAN 7.2X (Fronthaul Transport, red line), then to an O-CU via F1 (Midhaul Transport, orange line), and finally to a UPF via N3/9 (Backhaul Transport, blue line). The bottom topology shows an O-RU+O-DU connected to an O-CU via F1 (Midhaul Transport, orange line), and then to a UPF via N3/9 (Backhaul Transport, blue line). A legend at the bottom identifies the transport types: Fronthaul Transport (red), Midhaul Transport (orange), and Backhaul Transport (blue). A note 'Not to scale' is also present.](ebeba7d2b5c1d5689122468a47833c28_img.jpg) + +Figure 5: RAN architectures where a Midhaul transport is required. The diagram shows two network topologies. The top topology shows an O-RU connected to an O-DU via O-RAN 7.2X (Fronthaul Transport, red line), then to an O-CU via F1 (Midhaul Transport, orange line), and finally to a UPF via N3/9 (Backhaul Transport, blue line). The bottom topology shows an O-RU+O-DU connected to an O-CU via F1 (Midhaul Transport, orange line), and then to a UPF via N3/9 (Backhaul Transport, blue line). A legend at the bottom identifies the transport types: Fronthaul Transport (red), Midhaul Transport (orange), and Backhaul Transport (blue). A note 'Not to scale' is also present. + +**Figure 5: RAN architectures where a Midhaul transport is required** +Source: Cisco + +From an interface and protocol perspective 3GPP and O-RAN WG5 are defining these specifications. + +Note: WG5 will shortly publish O-RAN Transport Specifications 1.0 on the transport requirements for Midhaul . The requirements should be used in conjunction with this document. + +### 8.1.1 O-DU to O-CU communications + +3GPP TS 38.401.[58] defines the de-aggregated RAN, it's characteristics and outlines the F1-U, F1-C and E1 interfaces. Figure 6, taken from 3GPP TS 38.401 illustrates the components and interfaces. The Midhaul transport infrastructure is responsible for supporting these interfaces. + +![Figure 6: De-aggregated gNB [58]. The diagram shows a gNB (dashed box) containing a gNB-CU-CP, multiple gNB-CU-UPs, and multiple gNB-DUs. The gNB-CU-CP is connected to the gNB-CU-UPs via the E1 interface. The gNB-CU-CP is connected to the gNB-DUs via the F1-C interface. The gNB-CU-UPs are connected to the gNB-DUs via the F1-U interface.](6567859df66d9102817e1d0cbfb88d3b_img.jpg) + +Figure 6: De-aggregated gNB [58]. The diagram shows a gNB (dashed box) containing a gNB-CU-CP, multiple gNB-CU-UPs, and multiple gNB-DUs. The gNB-CU-CP is connected to the gNB-CU-UPs via the E1 interface. The gNB-CU-CP is connected to the gNB-DUs via the F1-C interface. The gNB-CU-UPs are connected to the gNB-DUs via the F1-U interface. + +**Figure 6: De-aggregated gNB [58]** + +The characteristics of a disaggregated gNB are: + +- A gNB may consist of a gNB-CU-CP, multiple gNB-CU-UPs and multiple gNB-DUs +- DUs and CU-UPs are connected to one CU-CP via the E1 interface +- DUs can connect to multiple CU-UPs +- Multiple CU-UPs connect to one CU-CP +- For resiliency reasons DUs and CU-UPs may connect to multiple CU-CPs + +The 3GPP interfaces associated with O-DU and O-CU communication are: + +- **F1 interface** defines the inter-connection of a gNB-CU and a gNB-DU and has a control (F1-C) and user (F1-U) plane component. +- **E1 interface** defines the control plane inter-connection between the gNB-CU-CP and a gNB-CU-UP. It allows these two components to run as separate entities and potentially in different locations. + +### 8.1.2 Inter O-CU communications + +Xn is a 5G interface between the gNBs in 5G and X2 is the interface between eNBs in 4G. Figure 7 illustrates Xn interface in a D-RAN architecture. + +![Figure 7: Overall Architecture showing Xn interface [65]. The diagram illustrates the 5G Core Network (5GC) and the Next-Generation Radio Access Network (NG-RAN). The 5GC consists of two AMF/UPF nodes. The NG-RAN consists of two gNBs and two ng-eNBs. The gNBs are connected to the AMF/UPF nodes via NG interfaces. The ng-eNBs are connected to the gNBs via Xn interfaces. The ng-eNBs are also connected to the AMF/UPF nodes via NG interfaces. The Xn interface is used for signaling and data exchange between the gNBs and ng-eNBs.](cecb22afa8bb5346db92d9dcbcfbdb6d_img.jpg) + +Figure 7: Overall Architecture showing Xn interface [65]. The diagram illustrates the 5G Core Network (5GC) and the Next-Generation Radio Access Network (NG-RAN). The 5GC consists of two AMF/UPF nodes. The NG-RAN consists of two gNBs and two ng-eNBs. The gNBs are connected to the AMF/UPF nodes via NG interfaces. The ng-eNBs are connected to the gNBs via Xn interfaces. The ng-eNBs are also connected to the AMF/UPF nodes via NG interfaces. The Xn interface is used for signaling and data exchange between the gNBs and ng-eNBs. + +**Figure 7: Overall Architecture showing Xn interface [65]** + +In scenarios where a “high level split” radio architecture has been adopted these interfaces run between the O-CUs and are considered to be part of the Midhaul transport architecture by O-RAN WG5. In D-RAN and RAN architectures that do not employ an HLS, then these interfaces will typically be considered part of the Backhaul network. + +The Xn and X2 interfaces are used to exchange signalling information between RAN nodes, and the forwarding of PDUs between RAN nodes during UE handover. The X2 interface also has an important role in the migration from 4G to 5G as it is used in some Non-Standalone Architectures (NSAs) migration solutions to convey signalling information, and in some cases user data from the 5G New Radios to the 4G Evolved Packet Core. + +![Figure 8: NSA Option 3/3a/3x networking mode [66]. The diagram shows three scenarios of NSA Option 3/3a/3x networking mode. In all three, a 5G NR UE is connected to an NR gNB, which is connected to an LTE eNB, which is connected to the EPC. The scenarios differ in the control plane and user plane traffic flow. In the first scenario (left), the control plane traffic goes from the NR gNB to the LTE eNB and then to the EPC. In the second scenario (middle), the control plane traffic goes from the NR gNB to the EPC. In the third scenario (right), the control plane traffic goes from the NR gNB to the LTE eNB and then to the EPC, and the user plane traffic goes from the NR gNB to the LTE eNB and then to the EPC.](ffdcbeea5ca0bf1e55b189f3bb4224de_img.jpg) + +Figure 8: NSA Option 3/3a/3x networking mode [66]. The diagram shows three scenarios of NSA Option 3/3a/3x networking mode. In all three, a 5G NR UE is connected to an NR gNB, which is connected to an LTE eNB, which is connected to the EPC. The scenarios differ in the control plane and user plane traffic flow. In the first scenario (left), the control plane traffic goes from the NR gNB to the LTE eNB and then to the EPC. In the second scenario (middle), the control plane traffic goes from the NR gNB to the EPC. In the third scenario (right), the control plane traffic goes from the NR gNB to the LTE eNB and then to the EPC, and the user plane traffic goes from the NR gNB to the LTE eNB and then to the EPC. + +**Figure 8: NSA Option 3/3a/3x networking mode [66]** +**Source: GSMA 5G Implementation Guidelines v2: NSA Option 3** + +Figure 8 shows the NSA option 3/3a/3x networking modes. In NSA option 3 (far left in figure) the signalling and user plane traffic associated with 5G UEs is sent from gNBs to eNBs and then onto the mobile core. In this mode, traffic levels between the gNB and the eNB and between the eNB and the EPC are a function of the amount of 5G spectrum and the number of 5G UEs. It is anticipated traffic levels will initially be low due to the scarcity of 5G UEs but could become very significant as the user population transitions towards 5G UEs and gets the benefits of increased capacity from using 5G NR. This mode impacts the transport infrastructure between the gNB and the eNB and also the transport infrastructure between the eNB and the EPC. + +In NSA option 3a (middle of Figure 8) only signalling traffic traverses the X2 interface. NSA option 3x (far right in Figure 8) is roughly the opposite to NSA option 3. In this case signalling and user plane traffic from 4G UEs goes from eNBs via gNBs to the mobile core. In this NSA mode, the impact on the transport network is dependent on the level of 4G spectrum and the number of 4G UEs. The likely impact on the transport network is that traffic levels will be significant on the X2 interface initially, but as 4G users migrate to 5G so user plane traffic will decrease. + +X2 and Xn are logically a point to point connection between gNBs or eNBs. However, there are Xn and X2 interfaces to all adjacent eNBs / gNBs so in reality there is a multi-point relationship between entities. + +The O-CU-O-CU interfaces are: + +- **X2 interface** is the LTE interface between RAN nodes. The interface is further split into a user plane and control plane components (X2-U user plane and the X2-C). +- **Xn interface** is the 5G interface between RAN nodes. The interface is further split into a user plane and control plane components (Xn-U user plane and the Xn-C). + +## 8.2 Midhaul requirements + +There are many similarities between Midhaul and Backhaul transport requirements. The following table highlights the items specific to Midhaul. For requirements that are consistent between Midhaul and Backhaul please refer to Table 6 in the Backhaul section. + +| Capability | Requirements | Notes | +|-------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------| +| 3GPP interfaces | Control Plane: F1-C, E1<br>User Plane: F1-U<br>Control Plane: Xn-C<br>User Plane: Xn-U | | +| Network and transport protocols | All 3GPP interfaces are IP<br>Control plane interfaces: IP/SCTP<br>User plane interfaces: IP/UDP/GTPv2 | | +| Logical connectivity requirements | Multi-point at IP layer | | +| Transport network scale for Midhaul | The size of the Midhaul infrastructure is highly dependent on how the C-RAN architecture is deployed.<br><br>In scenarios where an operator is running a Fronthaul infrastructure then the Midhaul will be between O-DU sites and the O-CU sites (1 <sup>st</sup> topology shown in figure xx). In both cases there could be aggregation. <ul style="list-style-type: none"> <li>1) Multiple O-RUs consolidating onto a smaller number of O-DU sites.</li> <li>2) Multiple O-DUs consolidating onto a smaller number of O-CU sites.</li> </ul> | | + +| | | | +|----------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------| +| | In scenarios where the O-RU and the O-DU are co-located in the cell site (2 <sup>nd</sup> topology shown in Figure 5) then the Midhaul will consist of every cell site plus sites where an O-CU component resides. | | +| Midhaul transport provisioning | F1 and E1 interfaces dimensioning is covered in chapter 10.<br>Xn and X2 interfaces are between gNBs and eNBs and traffic levels are highly dependent on the migration path being used by the MNO to move between 4G and 5G technology. | | +| End to end Midhaul transport delay (one way) | <p>Delay constraint for midhaul are derived mainly from the target service's latency requirements, rather than specific requirements of the Midhaul's user or control planes. As service delay targets become tighter it may become necessary to:</p> <ol style="list-style-type: none"> <li>1) Place Midhaul and Backhaul mobile components in close proximity to each other to reduce the delay impact of the transport network.</li> <li>2) Combine mobile functions together so 3GPP interfaces run internally within a "Network Function" or within a data center to remove the delay impact associated with the WAN transport network. For example, combining O-RU, O-DU and O-CU or combining the O-DU and O-CU functions together.</li> </ol> <p><1.5ms-10ms [83]</p> | See section 10.3 for more detail. | + +**Table 5: Midhaul transport requirements.** + +**For generic Midhaul and Backhaul requirements please see Table 6: Common Midhaul / Backhaul Xhaul transport requirements.** + +1 +2 +3 +4 +5 +6 +7 +8 + +# 9 Backhaul + +There are many similarities between Midhaul and Backhaul components of a 5G RAN infrastructure and the transport infrastructure needed to support it. In order to avoid duplication this document has dedicated chapters covering Midhaul and Backhaul. These contain descriptions of the component and a requirements table. For requirements that are common for both Midhaul and Backhaul they are held in the Backhaul requirements section (see section 9.3). There is also a common chapter (chapter 0) dedicated to dimensioning the transport network. + +## 9.1 Backhaul details + +From a 5G architectural perspective Fronthaul, Midhaul and Backhaul components and associated interfaces are always present. However, the impact on the transport architecture depends on where the different 3GPP components are placed and their proximity to each other. In a traditional D-RAN architecture the O-RU, O-DU, O-CU (or equivalent 4G components) are either integrated together or contained within a single cell site and the transport network for Backhaul run from the cell site to the mobile core. In a C-RAN NR architecture or disaggregated RAN architecture the Backhaul network connects the “Centralised Unit” (O-CU) to the mobile core components. + +Figure 9 shows some examples of how the placement of the various 5G NR components determines the size of the transport network associated with the Backhaul. The bottom architecture is a D-RAN architecture while all the others are C-RAN derivatives. + +![Figure 9: Backhaul layout with various RAN splits. The diagram shows four horizontal architectures. Top: O-RU connected to O-DU via O-RAN 7.2X (red line), O-DU to O-CU via F1 (blue line), O-CU to UPF via N3/9 (blue line). Second: O-RU connected to O-DU via O-RAN 7.2X (red line), O-DU and O-CU are integrated (red/orange box), connected to UPF via N3/9 (blue line). Third: O-RU and O-DU are integrated (orange box), connected to O-CU via F1 (blue line), O-CU to UPF via N3/9 (blue line). Bottom: O-RU, O-DU, and O-CU are integrated (blue box), connected to UPF via N3/9 (blue line). A legend at the bottom indicates: Red line = FRONTHAUL TRANSPORT, Orange line = MIDHAUL TRANSPORT, Blue line = BACKHAUL TRANSPORT. A 'Not to scale' box is also present.](f1f0a88cd54e4260ac2f0ef804bf4d0b_img.jpg) + +Figure 9: Backhaul layout with various RAN splits. The diagram shows four horizontal architectures. Top: O-RU connected to O-DU via O-RAN 7.2X (red line), O-DU to O-CU via F1 (blue line), O-CU to UPF via N3/9 (blue line). Second: O-RU connected to O-DU via O-RAN 7.2X (red line), O-DU and O-CU are integrated (red/orange box), connected to UPF via N3/9 (blue line). Third: O-RU and O-DU are integrated (orange box), connected to O-CU via F1 (blue line), O-CU to UPF via N3/9 (blue line). Bottom: O-RU, O-DU, and O-CU are integrated (blue box), connected to UPF via N3/9 (blue line). A legend at the bottom indicates: Red line = FRONTHAUL TRANSPORT, Orange line = MIDHAUL TRANSPORT, Blue line = BACKHAUL TRANSPORT. A 'Not to scale' box is also present. + +**Figure 9: Backhaul layout with various RAN splits** +source: Cisco + +Figure 10 shows components and the 3GPP interfaces in the mobile Backhaul. It has a control plane component and user plane component. It is not uncommon to see the control plane and the user plane divided into separate closed user groups at the transport layer to ensure a clear demarcation between customer user data and the 3GPP control plane. + +![Figure 10: 5G Backhaul components and interfaces. The diagram shows the 5G core network architecture. Key components include UE, (R)AN, AMF, SMF, PCF, AF, UPF, and DN. Interfaces are labeled N1 through N15. The diagram is shaded to distinguish between the control plane (CP) and user plane (UP). The control plane (CP) is shaded light blue and includes the AMF, SMF, PCF, AF, and the N1, N2, N4, and N14 interfaces. The user plane (UP) is shaded light blue and includes the UE, (R)AN, UPF, DN, and the N3, N6, N7, N9, and N15 interfaces. The (R)AN component is shaded light blue and connects the UE to the UPF via the N3 interface. The UPF component is shaded light blue and connects the (R)AN to the DN via the N6 interface. The AMF component is shaded light blue and connects the UE via the N1 interface and the SMF via the N11 interface. The SMF component is shaded light blue and connects the AMF via the N11 interface and the PCF via the N7 interface. The PCF component is shaded light blue and connects the SMF via the N7 interface and the AF via the N5 interface. The AF component is shaded light blue and connects the PCF via the N5 interface. The DN component is shaded light blue and connects the UPF via the N6 interface. The N9 interface is a user plane interface that runs between two UPFs. (i.e. an intermediate UPF and the UPF session anchor).](67d337316e6534290a153c53dad8044b_img.jpg) + +Figure 10: 5G Backhaul components and interfaces. The diagram shows the 5G core network architecture. Key components include UE, (R)AN, AMF, SMF, PCF, AF, UPF, and DN. Interfaces are labeled N1 through N15. The diagram is shaded to distinguish between the control plane (CP) and user plane (UP). The control plane (CP) is shaded light blue and includes the AMF, SMF, PCF, AF, and the N1, N2, N4, and N14 interfaces. The user plane (UP) is shaded light blue and includes the UE, (R)AN, UPF, DN, and the N3, N6, N7, N9, and N15 interfaces. The (R)AN component is shaded light blue and connects the UE to the UPF via the N3 interface. The UPF component is shaded light blue and connects the (R)AN to the DN via the N6 interface. The AMF component is shaded light blue and connects the UE via the N1 interface and the SMF via the N11 interface. The SMF component is shaded light blue and connects the AMF via the N11 interface and the PCF via the N7 interface. The PCF component is shaded light blue and connects the SMF via the N7 interface and the AF via the N5 interface. The AF component is shaded light blue and connects the PCF via the N5 interface. The DN component is shaded light blue and connects the UPF via the N6 interface. The N9 interface is a user plane interface that runs between two UPFs. (i.e. an intermediate UPF and the UPF session anchor). + +**Figure 10: 5G Backhaul components and interfaces** + +**Source: Adapted from 3GPP TS 23.501 v6.4.0(2020-03): System Architecture for 5G [67] with control plane / user plane shading added by document authors.** + +The 5G 3GPP interfaces associated with Backhaul are: + +- **N1 interface** is a logical control plane interface between the mobile core network and the UE. From a physical perspective it flows via the RAN through the Backhaul infrastructure to the AMF. It is a signalling interface between the UE and the AMF. +- **N2 interface** supports control plane signalling between RAN and 5G core. It is primarily concerned with connection management, UE context and PDU session management, and UE mobility management. In addition, Non-Access Spectrum (NAS) signalling between the UE and the AMF is transported over the N2 connection for that UE. This signalling includes information regarding access control, authentication and authorization, and session management procedures. +- **N4 Interface** is the bridge between the control plane and the user plane of the 5GC. It runs between the SMF and the UPF and is responsible for conveying policy rules regarding policy handling, forwarding and usage reporting to the UPF. +- **N3 interface** is the user plane interface between the O-CU component of the (gNB) and the initial UPF. +- **N9 interface** is a user plane interface than runs between two UPFs. (i.e. an intermediate UPF and the UPF session anchor). + +## 9.2 Backhaul transport evolution in 5G + +The RAN Backhaul network has been a feature of every 3GPP generation, and many transport network engineers are familiar with the transport requirements RAN Backhaul of previous 3GPP + +generations. However, 5G introduces some significant changes that will alter the requirements and nature of the Backhaul infrastructure. + +In the past 3GPP interfaces across the Backhaul networks tended to be hub and spoke in nature, with the radios at the edge and the mobile core control and user planes gateway components located in a fairly centralised location. See Figure 11 for details. + +![Figure 11: Transport organization of tradition Backhaul networks (Source Cisco). The diagram shows a central cloud representing the transport network. On the left, three 'Cell' icons are connected to the cloud via '3GPP control plane interfaces' (dotted lines) and '3GPP User plane interfaces (GTP tunnels)' (solid lines). On the right, the cloud connects to 'S/PGWs' (Service and Proxy Gateways), which then connect to three colored clouds: 'Consumer GiLAN' (orange), 'Enterprise GiLAN' (blue), and 'MVNO GiLAN' (green). A box labeled 'Mobile control plane' is also connected to the central cloud.](d25635c5860743ef13414a5887a8eb46_img.jpg) + +Figure 11: Transport organization of tradition Backhaul networks (Source Cisco). The diagram shows a central cloud representing the transport network. On the left, three 'Cell' icons are connected to the cloud via '3GPP control plane interfaces' (dotted lines) and '3GPP User plane interfaces (GTP tunnels)' (solid lines). On the right, the cloud connects to 'S/PGWs' (Service and Proxy Gateways), which then connect to three colored clouds: 'Consumer GiLAN' (orange), 'Enterprise GiLAN' (blue), and 'MVNO GiLAN' (green). A box labeled 'Mobile control plane' is also connected to the central cloud. + +**Figure 11: Transport organization of tradition Backhaul networks (Source Cisco)** + +With the advent of new 5G use cases, CUPS, MEC and slicing both the control and user plane Backhaul interfaces will become more multi-point in nature, with IP end points needing to communicate with other IP end points distributed around the whole transport network. This connectivity can be provided using either L3 routing or E-LAN / E-Tree services or a combination of both. In addition, with the advent of 5G slicing the transport network will need to support multiple L2 and L3 closed user groups on the transport infrastructure and in some cases permit controlled connectivity between and within closed user groups. See Figure 12 for details. + +![Figure 12: 5G Backhaul infrastructure overlaying the transport infrastructure (Source Cisco). The diagram shows a complex multi-point architecture. On the left, three 'e/gNB' icons connect to a central cloud. The cloud is divided into three colored regions: 'Blue backhaul', 'Green backhaul', and 'Yellow backhaul'. Each region contains 'UPFs' (User Plane Functions) and connects to a corresponding '3GPP control plane' (Blue, Green, and Yellow respectively). On the right, these regions connect to 'UPFs' and then to three colored clouds: 'Blue N6', 'Green N6', and 'Yellow N6'. A 'Green 3GPP control plane' is also shown at the top right.](d6f89c8c8eb988aed1544a26b9233947_img.jpg) + +Figure 12: 5G Backhaul infrastructure overlaying the transport infrastructure (Source Cisco). The diagram shows a complex multi-point architecture. On the left, three 'e/gNB' icons connect to a central cloud. The cloud is divided into three colored regions: 'Blue backhaul', 'Green backhaul', and 'Yellow backhaul'. Each region contains 'UPFs' (User Plane Functions) and connects to a corresponding '3GPP control plane' (Blue, Green, and Yellow respectively). On the right, these regions connect to 'UPFs' and then to three colored clouds: 'Blue N6', 'Green N6', and 'Yellow N6'. A 'Green 3GPP control plane' is also shown at the top right. + +**Figure 12: 5G Backhaul infrastructure overlaying the transport infrastructure (Source Cisco)** + +## 9.3 Backhaul and Midhaul transport requirements + +The transport requirements for Midhaul and Backhaul are very similar. The table below captures Backhaul and common Midhaul / Backhaul transport requirements. For transport requirements specific only to Midhaul please refer to Table 6. + +| Capability | Requirements | Notes | +|---------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 3GPP interfaces | Control Plane: N1, N2, N4<br>User Plane: N3, N9 | | +| Network and transport protocols | All 3GPP interfaces are IPv4 or IPv6<br>Control plane: IP/SCTP<br>Data plane: IP/UDP/GTPv2 | | +| Logical connectivity requirements | Control Plane: Multi-point connectivity at the IP interface level (IPv4 or IPv6) between mobile components.<br>User Plane: Multi-point at the IP interface level (IPv4 or IPv6) between mobile components | This requirement could be met by the use of an L3 or an L2 solution or a combination of the two. Technology solution for the transport network to meet these requirements will be covered in technology specific O-RAN documents or by transport solutions specified by other organization. Later revisions of this document will reference these documents. | +| Scope of the transport network for Midhaul and Backhaul | The transport network consists of WAN components, the networking (switching) infrastructure within the DCs and Network Functions (physical or virtual) in DCs.<br><br><b>R1:</b> The WAN transport network and the DC transport networks <b>MUST</b> inter-operate together and allow end to end connectivity between transport components and creation of transport slices that have components in the WAN and the DC.<br><br>Midhaul and Backhaul have strong similarities. These include:<br><br>1) IP endpoints with common protocols used in the Midhaul and Backhaul networks.<br>2) The O-CU is part of the 3GPP Midhaul and the Backhaul network, so from a | | + +| | | | +|--------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>transport network perspective, Midhaul and Backhaul connectivity is presented by different physical or logical interfaces in the same “Network Function” (NF) and most likely same physical locations.</p> <p>3) For deployment reasons, some radios in a cell site may be running a D-RAN architecture and other radios may be running a C-RAN architecture. Consequently, the same part of the transport network could be running both Midhaul and Backhaul services.</p> <p><b>R2:</b> With these commonalities and overlaps strong consideration <b>MUST</b> be given by operators to designing, building and operating a single packet orientated transport infrastructure that supports both Midhaul and Backhaul services.</p> <p><b>R3:</b> In scenarios where a common transport technology is used in Backhaul, Midhaul and Fronthaul then an operator <b>MAY</b> choose to build a common end-to-end transport infrastructure supporting Backhaul, Midhaul and Fronthaul.</p> | | +| Transport network scale for Backhaul | <p><b>R4:</b> For national mobile infrastructures the Transport network architecture: <b>MUST</b> support mobile networks up to 100,000 O-RU locations. <b>MAY</b> support mobile networks up to 500,000 O-RU locations.</p> | <p>The size of a Backhaul infrastructure depend on the radio architecture. In D-RAN scenarios the transport network could potentially need to support these very large numbers of transport endpoints. The number of endpoints in the Backhaul will be smaller if radio architectures based on Fronthaul, Midhaul or both are implemented.</p> <p>The architectural solution needs to scale to very large number of transport endpoints without exhausting key transport resources or significantly inflating the transport solution costs.</p> | + +| | | | +|-------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <p>Transport<br/>infrastructure</p> | <p><b><u>Physical interfaces</u></b><br/> Mobile equipment associated with Midhaul and Backhaul present Ethernet interfaces at the data link layer.</p> <p>In Midhaul and Backhaul the mobile equipment runs IPv4 and/or IPv6 at the network layer.</p> <p><b><u>User Network Interface - Customer (UNI-C)</u></b><br/> <b>R5:</b> The Midhaul and Backhaul transport network <b>MUST</b> support physical Ethernet interfaces at the UNI-C. See Figure to the right.</p> <p><b>R6:</b> The Midhaul and Backhaul transport network <b>MUST</b> support Ethernet services based on a full Ethernet port towards the end-user. For example, an EPL service as defined by MEF 6.2.</p> <p><b>R7:</b> The Midhaul and Backhaul transport network <b>MUST</b> support Ethernet virtual services based on VLANs within an Ethernet port towards the end user. For example, an EVPL services as defined by MEF 6.2</p> <p><b>R8:</b> The Midhaul and Backhaul transport network <b>MUST</b> support subscriber IP services. For example, as defined by MEF61.1.</p> <p><b>R9:</b> The transport network <b>MUST</b> support subscriber IP services on a full Ethernet port basis or over VLANs within an Ethernet port.</p> <p><b>R10:</b> Subscriber IP services <b>MUST</b> be supported over a single UNI Access link.</p> <p><b>R11:</b> Subscriber IP services <b>MAY</b> be supported over:</p> <ol style="list-style-type: none"> <li>1) UNI access links terminating on different devices at the SP.</li> <li>2) UNI Access links terminating on different devices at the SP and the subscriber.</li> <li>3) UNI Access links terminating on different devices at the subscriber</li> </ol> <p><b>R12:</b> The transport network <b>MUST</b> support ingress bandwidth control mechanisms for Ethernet, IPv4 and IPv6. This is applied to traffic flowing across the UNI interface from the subscriber towards the transport network.</p> | <p>See ORAN-WG5 transport specification for Midhaul equipment. [60]</p> <div data-bbox="1098 598 1409 770" data-label="Diagram"> <img alt="Diagram of User Network Interface (UNI) showing a radio tower connected to a cloud labeled 'Transport Network' via a line labeled 'UNI'. Labels include 'UNI-C: User to Network Interface-customer' and 'UNI-N: User to Network Interface-network'." data-bbox="1098 598 1409 770" src="306e8a040aee98b97f117a4980977f1c_img.jpg"/> </div> <p>Refer to MEF 61.1 [68] section 7.3 for more details on IP service UNIs</p> <p>See MEF 61.1 [68] “Bandwidth Profiles” for examples of typical</p> | +|-------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | | +|--|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>1) Ingress classification and packet marking</li> <li>2) Ingress traffic conditioning bases on classes with an Ethernet port.</li> <li>3) Hierarchical ingress traffic conditioning based on VLANs and classes within the VLAN.</li> </ol> <p><b>R13:</b> The transport network <b>MUST</b> support egress bandwidth control mechanisms for Ethernet, IPv4 and IPv6. This is applied to traffic flowing across the UNI interface towards the end-user.</p> <ol style="list-style-type: none"> <li>1) Egress traffic conditioning and scheduling based on classes with an Ethernet port.</li> <li>2) Hierarchical ingress traffic conditioning and scheduling based on VLANs and classes within the VLAN.</li> </ol> <p><b><u>Transport Services</u></b></p> <p><b>R14:</b> The transport infrastructure <b>MUST</b> support mechanisms to create:</p> <ol style="list-style-type: none"> <li>1) Basic IPv4 and IPv6 routing infrastructure</li> <li>2) IPv4 or IPv6 Virtual Private Networks – any to any</li> <li>3) IPv4 or IPv6 Virtual Private Networks – controlled access</li> <li>4) IPv4 or IPv6 Virtual Private Networks with extranet</li> <li>5) EPL and EVPL</li> <li>6) EP-LAN and EVP-LAN</li> <li>7) EP-Tree and EVP-Tree</li> </ol> <p><b><u>Transport network QoS and availability</u></b></p> <p><b>R15:</b> Transport network <b>MUST</b> have mechanisms or utilise an architecture that implements Quality of Service based on QoS markings within the actual Midhaul / Backhaul packet.</p> <p>QoS markings could be Ethernet class of service markings, MPLS class of service marking, IPv4 DSCP or IPv6 traffic class marking. The appropriate QoS scheme will be determined by the transport architecture employed.</p> | <p>actions applied on ingress and egress for IP services</p> <p>See MEF 10.3 [69]“Bandwidth Profiles” for examples of typical actions applied on ingress and egress of Ethernet services</p> <p>Refer to MEF 61.1 [68] for details of IP services</p> <p>Ref to MEF 6.2 [70] for details of Ethernet services</p> | +|--|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | | +|--|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------| +| | <p><b>R16:</b> Transport network <b>MUST</b> support QoS / availability mechanisms to enable SLAs to be offered to support 5G slices.</p> <p>Transport network SLAs for slices cover IP network delay characteristics and IP network availability.</p> <p><b>R17:</b> Transport network <b>MUST</b> support mechanisms to ensure suitable behavioural isolation between transport slices on access and within the core of the transport network.</p> <p><b>R18:</b> Transport network <b>MUST</b> support mechanisms to control and map a transport slice to the transport network's physical topology.</p> <p><b>R19:</b> Transport network <b>MUST</b> implement transport slice protection / restorations schemes that allow 50ms protection of IP connectivity between slice endpoints.</p> <p><b>R20:</b> The transport network <b>MAY</b> support other mechanisms to improve Transport slice reliability between IP endpoints. These could be protection mechanisms or other schemes such as multi-path traffic delivery.</p> <p><b><u>Transport network OAM and management</u></b></p> <p><b>R21:</b> Transport equipment (DC and WAN) <b>MUST</b> support standard model-based approaches to support basic device and network configuration.</p> <p><b>R22:</b> If appropriate, transport equipment (DC and WAN) <b>MUST</b> support standard model-based approaches to configure transport slices.</p> <p><b>R23:</b> Transport equipment <b>MUST</b> support OAM tools to test link level capabilities.</p> <p><b>R24:</b> Transport equipment <b>MUST</b> support OAM tools to test end to end connectivity.</p> <p><b>R25:</b> Mechanisms <b>MUST</b> exist to determine the liveness of transport network equipment.</p> <p><b>R26:</b> Mechanisms <b>MUST</b> exist to determine liveness of services running on the transport network</p> | <p>Note: A transport NSSI is not necessarily a network wide phenomenon. It may only be running in a small section of the network.</p> | +|--|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------| + +| | | | +|-------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------| +| | <p><b>R27:</b> Mechanisms <b>MUST</b> exist to determine delay and jitter of services running on the transport network</p> | | +| Transport slicing<br>for 3GPP<br>Backhaul | <p><b>R28:</b> Transport network <b>MUST</b> support network slicing for the 3GPP Backhaul network.</p> <p><b><u>Transport slice scale</u></b></p> <p><b>R29:</b> The transport network slicing architecture <b>MUST</b> support the key 5G services and within each service type support 1000s of different customers that require isolation from each other.</p> <p><b>R30:</b> The transport network slicing architecture <b>MUST</b> be capable of extending to every end site and also every DC locations.</p> <p><b><u>Transport Slice capabilities</u></b></p> <p><b>R31:</b> The transport slicing solution <b>MUST</b> support the creation of slices that span from the WAN into the DC networking infrastructure.</p> <p><b>R32:</b> Midhaul / Backhaul transport slices <b>MUST</b> allow:</p> <ol style="list-style-type: none"> <li>1) Multi-point connectivity model between IP endpoints.</li> <li>2) Connectivity between 3GPP components residing solely in the WAN space.</li> <li>3) Connectivity between 3GPP components residing in either the same data center or different data centers</li> <li>4) Connectivity between 3GPP components residing in the WAN and 3GPP components residing in a data center.</li> <li>5) For a NF (physical or virtual) to inject and learn slice connectivity information from either WAN or DC transport components.</li> </ol> <p><b>R33:</b> In situations where an operator builds a common transport infrastructure for Midhaul and Backhaul. Transport slices <b>MAY</b> be built so a common transport slice covers both the Midhaul and Backhaul interfaces or they <b>MAY</b> be built so there is a dedicated transport slice for</p> | Please refer to Annex B: Slicing in Backhaul and Midhaul | + +| | | | +|-----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------| +| | <p>Midhaul interfaces and another for Backhaul interfaces.</p> <p><b><u>Transport slice connectivity models</u></b></p> <p><b>R34:</b> Transport network <b>MUST</b> enable the creation of discrete any-to-any VPNs for different transport slices. End points will be IP entities and may reside in the WAN or a DC.</p> <p><b>R35:</b> Transport network <b>MUST</b> support the ability to run the Midhaul/Backhaul control plane and user plane of a slice in different VPNs.</p> <p><b>R36:</b> The transport network <b>MUST</b> support complete connectivity isolation within a Transport slice so only those entities associated with that slice instance can communicate at the transport layer.</p> <p><b>R37:</b> The transport network <b>MUST</b> support controlled connectivity from within one transport slice to IP entities that are either common to multiple slices or reside in another Transport slice. This is often termed Extranet connectivity</p> <p><b>R38:</b> The transport network <b>MUST</b> support controlled connectivity between IP entities within the same Transport slice.</p> <p><b><u>Transport slice OAM</u></b></p> <p><b>R39:</b> Transport network <b>MUST</b> support mechanisms to test and report transport slices edge-to-edge connectivity and response times to enable the performance of the transport slice to be monitored.</p> <p><b>R40:</b> Transport network <b>MUST</b> support mechanisms to export transport SLA measurement details to an external storage infrastructure.</p> | | +| Peak 5G DL data rates | <p>Peak 5G data rates are highly dependent on overall cell site configuration and radio characteristics. This document uses four example site configurations to illustrate bandwidth requirements. Theoretical 5G NR peak data bandwidths for each site type are:</p> <p>Small Site (FR1): 1.8Gbps<br/> Small Site (FR2): 3.3Gbps<br/> Medium Site (FR1 + FR2): 25.8Gbps</p> | See chapter 10 for more details on carrier and sector peak DL bandwidth. | + +| | | | +|-------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Large site (FR1 + FR2): 62.7Gbps | | +| Peak site 5G DL rates with encapsulation (all carriers and sectors included). | <p>An encapsulation overhead of 10% has been used to calculate the peak 5G DL traffic rates.</p> <p>Small Site (FR1) (1 sector): 2.0Gbps<br/>Small Site (FR2) (1 sector): 3.7Gbps<br/>Medium Site (FR1 + FR2) (3 sector): 28.4Gbps<br/>Large site (FR1 + FR2) (3 sector): 68.8Gbps</p> | See chapter 10 for more details and considerations for selecting encapsulation overhead. | +| Transport provisioning | <p>Midhaul and Backhaul traffic is primarily made up of user data and precise levels depend on usage. When provisioning a statistically multiplexed transport network it is normal to assume a statistic multiplexing gain as the network travels from the edge towards the core in such networks</p> <p><b><u>Access provisioning</u></b></p> <p>Backhaul traffic is only present on access circuits in D-RAN architectures.<br/>Midhaul traffic is only present on access circuits when the RU/DU are co-located on the cell site.</p> <p>Using the four example site configurations and the empirical dimensioning rule outlined in chapter 10 shows the following bandwidth would be required on the access circuit. These figures are similar for scenarios where the access circuit supports Backhaul or Midhaul.</p> <p>Small Site (FR1 carrier only): ~2.0Gbps<br/>Small Site (FR2 carrier only): ~3.7Gbps<br/>Medium Site (FR1 + FR2 carriers): ~15.2Gbps<br/>Large site (FR1 + FR2 carriers): ~36.8Gbps</p> <p><b><u>Pre-Aggregation and Aggregation</u></b></p> <p>Dependent on SPs specific transport dimensioning and capacity planning rules. The statistical gain will increase as the traffic moves from the access towards the mobile core if the traffic is traversing statistically multiplexing equipment.</p> | <p>See chapter 10 for more details on different provisioning rules.</p> <p>It should be noted that even in single sector cell sites operators can choose to provision the access capacity below the peak radio rate of the site.</p> | +| Transport Technology | Not part of the scope of this document. | Please refer to specific technology orientated documents coming from WG-9 for technology and architectural details. | +| End to end Backhaul Transport delay (one way) | Delay constraint for Backhaul are derived mainly from the target service's latency requirements, rather than specific requirements of the Backhaul's user or control planes. As | Dependent on 5G service type. See 10.3 | + +| | | | +|---------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--| +| | <p>service delay targets become tighter it may become necessary to:</p> <p>3) Place Midhaul and Backhaul mobile components in close proximity to each other to reduce the delay impact of the transport network. For example, O-DU, O-CU and UPF in the same data center.</p> <p>4) Combine mobile functions together so 3GPP interfaces run internally within a “Network Function” or within a data center to remove the delay impact associated with the WAN transport network. For example, combining O-RU, O-DU and O-CU or combining the O-DU and O-CU functions together.</p> <p>1ms – 50ms service dependent.</p> | | +| Synchronization / timing requirements | See chapter 11 for synchronization and timing requirements. | | + +**Table 6: Common Midhaul / Backhaul Xhaul transport requirements plus specific Backhaul requirements** + +### NOTES: + +- 1) The above tables reference various documents from other standards organizations (for example the MEF). It is important to note that the requirement does not imply that the transport equipment, nor the transport network needs to be compliant with these particular documents. Rather these documents provide a good explanation or definition of the capability. +- 2) Technology solution for the transport network to meet these requirements will be covered in technology specific O-RAN documents or by other organizations specify transport solutions. + +# 10 Transport network dimensioning for Midhaul and Backhaul + +The Backhaul and Midhaul segments of a 5G network have many similarities in terms of dimensioning and provisioning rules which feed through to the transport network as requirements. This chapter covers transport dimensioning for Midhaul and Backhaul. + +## 10.1 Transport capacity and radio density with 5G + +5G represents a significant increase in capacity and size of the transport network over previous 3GPP generations. A common quote is 5G will bring a ten-fold increase in capacity, number of radios and end-user devices when compared with LTE. + +## 10.2 Backhaul and Midhaul transport planning + +Traffic rates in Midhaul and Backhaul traffic rates are highly dependent on end user usage and it is possible to dimension and provision the transport network for Midhaul and Backhaul assuming a statistic multiplexing gain. The precise gain will vary depending on the architecture of the transport infrastructure and the RAN architecture. There are three steps in dimensioning the transport network for Midhaul and Backhaul: + +- 1) Calculate the peak rate for sectors within a site +- 2) Add Midhaul and Backhaul transport overheads +- 3) Calculate peak and average site usage +- 4) Apply a statistical multiplexing factor to determine the bandwidth to provision in various parts of the Midhaul and Backhaul transport network. + +### 10.2.1 5G NR peak bandwidth + +5G NR increases the data volumes seen in Backhaul, and if implemented in Midhaul, compared with previous generations of 3GPP technology. The formula below calculates the peak 5G data bandwidth for a single sector site. + +$$\text{data rate (in Mbps)} = 10^{-6} \cdot \sum_{j=1}^J \left( v_{\text{Layers}}^{(j)} \cdot Q_m^{(j)} \cdot f^{(j)} \cdot R_{\text{max}} \cdot \frac{N_{\text{PRB}}^{BW(j),\mu} \cdot 12}{T_s^\mu} \cdot (1 - OH^{(j)}) \right)$$ + +Where + +- $j$ is the sum of the carriers +- $v_{\text{Layers}}^{(j)}$ is the number of MIMO layers +- $Q_m^{(j)}$ is the modulation order + - 2 - QPSK + - 4 - 16QAM + - 6 - 64QAM + - 8 - 256QAM +- $f^{(j)}$ is the scaling factor +- $R_{\text{max}}$ is 948/1024 +- $N_{\text{PRB}}^{BW(j),\mu}$ is RB allocation. Determined by subcarrier spacing, which can be elucidated from numerology ( $\mu$ ) and bandwidth. + +- $T_s^\mu = \frac{10^{-3}}{14 \times 2^\mu}$ is the average OFDM symbol duration in a subframe for numerology +- $\mu$ is the numerology (0-15kHz SCS, 1-30kHz SCS, 2-60kHz SCS, 3 – 120kHz SCS) +- $OH^{(j)}$ is the overhead (0.14-FR1 DL, 0.18-FR2 DL, 0.08-FR1 UL, 0.10-FR2 UL) + +For explanation of above formula see 3GPP TS 38.306 version 15.2.0 Release 15 [71] There are also multiple b/w calculators on the worldwide web. For example: <https://5g-tools.com/5g-nr-throughput-calculator/> which calculates both “Frequency Division Duplex” FDD and “Time Division Duplex” (TDD) use cases. + +#### Notes + +- 1) The calculated data rate is the theoretical maximum achievable by the radio/radios. Real data rates depend on the radio placement, configuration of the cell site, the surrounding area, number of active UEs, their capabilities and usage. +- 2) This figure does not include Backhaul or Midhaul transport overhead; namely IP/UDP and GTP and potentially IPSEC encapsulation. + +Table 7 shows the peak downlink (DL) data rates for some of the radio profiles outlined in Annex A of Fronthaul Interoperability Test Specification (IOT) document and the 5G NR radio components used in the small, medium and large sites examples used throughout this document. + +| O-RAN IOT Profile or site profiles | Frequency range | Mode | Carriers (j) | MIMO layers v(j) | DL Modulation | B/W (MHz) | $\mu$ | TDD slot format | Peak DL b/w (Gbps) | +|------------------------------------|-----------------|------|--------------|------------------|---------------|-----------|-------|-----------------|--------------------| +| Profile 1&2 | FR1 | TDD | 1 | 4 | 256QAM | 100 | 1 | Format 25 | 1.84 | +| Profile 3 (low) | FR2 | TDD | 1 | 2 | 256QAM | 100 | 3 | Format 25 | 0.85 | +| Profile 3 (high) | FR2 | TDD | 8 | 2 | 256QAM | 800 | 3 | Format 25 | 6.77 | +| Profile 1 | FR1 | FDD | 1 | 8 | 256QAM | 30 | 0 | NA | 1.37 | +| Profile 2 | FR1 | FDD | 1 | 8 | 256QAM | 20 | 1 | NA | 0.87 | +| Profile 3 | FR1 | FDD | 1 | 4 | 256QAM | 30 | 1 | NA | 0.67 | +| Profile 4 | FR1 | FDD | 1 | 4 | 256QAM | 20 | 0 | NA | 0.45 | +| Small site -FR1 | FR1 | TDD | 1 | 4 | 256QAM | 100 | 1 | Format 25 | 1.84 | +| Small site-FR2 | FR2 | TDD | 1 | 2 | 256QAM | 400 | 3 | Format 25 | 3.39 | +| Medium site | FR1 | TDD | 1 | 4 | 256QAM | 100 | 1 | Format 25 | 1.84 | +| Medium site | FR2 | TDD | 1 | 4 | 256QAM | 400 | 3 | Format 25 | 6.77 | +| Large site | FR1 | TDD | 1 | 16 | 256QAM | 100 | 1 | Format 25 | 7.34 | +| Large site | FR2 | TDD | 2 | 4 | 256QAM | 400 | 3 | Format 25 | 13.54 | + +Notes + +Frequency Range (FR1) refers to frequencies below 7.225 GHz + +Frequency Range (FR2) refers to frequency bands from 24.250 GHz to 52.6 GHz spectrum (also referred to as “millimeter wave range”) + +FDD mode: both uplink and downlink can transmit at the same time at different spectrum frequencies. + +TDD mode, both uplink and downlink use the same spectrum frequencies but at different times. + +Format 25 allocates 0.785714286 bandwidth to downlink + +Calculation for a 1 sector cell site. + +**Table 7: Peak Backhaul DL bandwidth for a selection of O-RAN IOT and 5G NR site examples** + +### 10.2.2 Site peak data rates + +To calculate the maximum downlink bandwidth, it is necessary to sum the bandwidths associated with all radios in the site and add encapsulation overhead. The peak 5G NR DL data rates associated with the three example site profiles; small, medium and large are shown below. + +Note: Only the 5G radio components are considered. In the real-world, previous generations of 3GPP technology will most likely be deployed alongside 5G NR, so these components also need to be added. + +| Frequency range | Mode | sectors | Carriers (j) | MIMO layers v(j) | DL Modulation | B/W (MHz) | $\mu$ | TDD slot format | Single sector DL b/w (Mbps) | Peak site DL b/w (Gbps) | +|-----------------|------|---------|--------------|------------------|---------------|-----------|-------|-----------------|-----------------------------|-------------------------| +| FR1 | TDD | 1 | 1 | 4 | 256QAM | 100 | 1 | 25 | 1836 | 1.84 | +| | | | | | | | | | | <b>Total (Gbps)</b> | +| | | | | | | | | | | 1.84 | + +**Table 8: FR1 small site peak DL data bandwidth** + +| Frequency range | Mode | sectors | Carriers (j) | MIMO layers v(j) | DL Modulation | B/W (MHz) | $\mu$ | TDD slot format | Single sector DL b/w (Mbps) | Peak site DL b/w (Gbps) | +|-----------------|------|---------|--------------|------------------|---------------|-----------|-------|-----------------|-----------------------------|-------------------------| +| FR2 | TDD | 1 | 1 | 2 | 256QAM | 400 | 3 | 25 | 3386 | 3.39 | +| | | | | | | | | | | <b>Total (Gbps)</b> | +| | | | | | | | | | | 3.39 | + +**Table 9: FR2 small site peak DL data bandwidth** + +| Frequency range | Mode | sectors | Carriers (j) | MIMO layers v(j) | DL Modulation | B/W (MHz) | $\mu$ | TDD slot format | Single sector DL b/w (Mbps) | Peak site DL b/w (Gbps) | +|-----------------|------|---------|--------------|------------------|---------------|-----------|-------|-----------------|-----------------------------|-------------------------| +| FR1 | TDD | 3 | 1 | 4 | 256QAM | 100 | 1 | 25 | 1836 | 5.5 | +| FR2 | TDD | 3 | 1 | 4 | 256QAM | 400 | 3 | 25 | 6772 | 20.3 | +| | | | | | | | | | | <b>Total (Gbps)</b> | +| | | | | | | | | | | 25.82Gbps | + +**Table 10: Medium site peak DL data bandwidth** + +| Frequency range | Mode | sectors | Carriers (j) | MIMO layers v(j) | DL Modulation | B/W (MHz) | $\mu$ | TDD slot format | Single sector DL b/w (Mbps) | Peak site DL b/w (Gbps) | +|-----------------|------|---------|--------------|------------------|---------------|-----------|-------|-----------------|-----------------------------|-------------------------| +| FR1 | TDD | 3 | 1 | 16 | 256QAM | 100 | 1 | 25 | 7344 | 2.32 | +| FR2 | TDD | 3 | 2 | 4 | 256QAM | 400 | 3 | 25 | 13544 | 40.63 | +| | | | | | | | | | | <b>Total (Gbps)</b> | +| | | | | | | | | | | 62.67 | + +**Table 11: Large site peak DL data bandwidth** + +To calculate the peak Backhaul and Midhaul transport bandwidth, add the network encapsulation overhead. This can be done by: + +- 1) Calculating the packet per second +- 2) Adding the network encapsulation overhead +- 3) Calculating the transport bandwidth + +Network encapsulation overhead depends on a number of factors including: + +- L1/L2 technology +- IPv4 or IPv6 +- Average packet size +- Mobile encapsulations +- Whether the Midhaul / Backhaul are running IPSEC or not. + +The NGMN Backhaul group in “Guidelines for LTE Backhaul Traffic Estimation” [72] use an overhead of 10% to represent a general case for Backhaul (it is also applicable to Midhaul). For an Ethernet transport, IPv4, with no IPSEC encryption and an IMIX packet size (576 bytes) this is a good approximation. If IPSEC is providing Midhaul or Backhaul encryption, then the packet size increases due to the IPSEC overhead. In this scenario NGMN Backhaul group in “Guidelines for LTE Backhaul Traffic Estimation” [72] use an overhead of 14%. + +| Site Type | Peak Backhaul b/w (Gbps) | +|-------------|--------------------------| +| Small (FR1) | 2.0 | +| Small (FR2) | 3.7 | +| Medium | 28.4 | +| Large | 68.8 | + +**Table 12: Peak Backhaul site bandwidth** + +Notes: + +- 1) Midhaul and Backhaul traffic is IP and use GTP as an encapsulation for user traffic. One of the main differences is Midhaul traffic carries the “Packet Data Convergence Protocol” (PDCP), while Backhaul does not. This would suggest that Midhaul traffic volumes are greater than Backhaul traffic volumes, however although PDCP adds overhead it can, through Ethernet and IP header compression reduce the size of the user’s packet size. For this reason, this document treats Backhaul and Midhaul traffic requirements as the same. + +### 10.2.3 Estimating cell site loads + +Backhaul and midhaul cell site throughput is the sum of all the traffic generated by all UEs using that site. UE throughput varies depending on the quality of the radio link to the gNB and the amount of spectrum assigned to it. 5G radios use adaptive modulation to adjust their data rates based on the radio conditions. In good conditions, where the UE has good signal strength from the radio and there is little interference, more information can be carried without errors for each unit of spectrum. This is in contrast with scenarios where the UE has low signal strength from the radio and interference levels are high. This is called spectrum efficiency and measured in bits per second, per Hz. + +The highest radio throughput occurs when there is high spectral efficiency and largest spectrum allocation for UEs. Typically, this occurs at quiet times when there are a small number of active UEs that is in close proximity to the radio. This is known as the Quiet Time Peak rate. As the number of UEs and distribution of UE’s around the cell site increases, so the busy time mean rate is seen. This is normally significantly lower than the quiet time peak rate and is impacted by interference between radios, carriers and UEs, along with environmental factors that impact signal strength and interference such as physical location of the cell site, its surroundings and other sources of interference. + +In the provisioning examples shown in Table 13, busy time mean has been calculated as 30% of quiet time peak. This is applicable to 4G implementations, however at this time it is not clear whether this figure is appropriate to 5G NR. Transport engineers will need to liaise with the radio engineers to ascertain this figure for 5G environments. + +### 10.2.4 Transport dimensioning and provisioning for Backhaul and Midhaul + +Regardless of the RAN architecture employed, the transport network consists of various segments. Figure 13 shows two of the most common splits of the transport network between the radio and the 5G core. In the first, there are three layers of transport infrastructure; access, pre-aggregation and aggregation. In the second, there are two layers of transport infrastructure; access and aggregations. In both cases the transport network needs to be considered as a whole, however potentially different technologies and provisioning rules apply in each segment. + +Notes: Neither diagrams show the core of the transport network which tends to be behind the 5G core components. + +![Figure 13: 5G Backhaul infrastructure overlays the transport infrastructure consisting of physical networks. Source: Cisco. The diagram shows two network architectures. The top architecture shows a sequence of components: a radio tower icon, a green cloud labeled 'Access', a blue cloud labeled 'Pre-aggregation', a red cloud labeled 'Aggregation', and a box labeled '5G Core'. The bottom architecture shows a radio tower icon, a green cloud labeled 'Access', a large red cloud labeled 'Aggregation', and a box labeled '5G Core'. Both architectures use router icons to connect the clouds.](a8a7791b8e7ed3d0f0cbb3b1685489d3_img.jpg) + +Figure 13: 5G Backhaul infrastructure overlays the transport infrastructure consisting of physical networks. Source: Cisco. The diagram shows two network architectures. The top architecture shows a sequence of components: a radio tower icon, a green cloud labeled 'Access', a blue cloud labeled 'Pre-aggregation', a red cloud labeled 'Aggregation', and a box labeled '5G Core'. The bottom architecture shows a radio tower icon, a green cloud labeled 'Access', a large red cloud labeled 'Aggregation', and a box labeled '5G Core'. Both architectures use router icons to connect the clouds. + +**Figure 13: 5G Backhaul infrastructure overlays the transport infrastructure consisting of physical networks. Source: Cisco** + +#### 10.2.4.1 D-RAN Backhaul dimension + +In a D-RAN architecture the Backhaul component of the network goes from the cell site to mobile core which tend to be positioned centrally. + +##### 10.2.4.1.1 Access (last mile) provisioning + +Access or last mile provisioning depends on the number of radios in each cell site location. + +NGMA in “Guidelines for LTE Backhaul Traffic Estimation” [72] recommends for single cell last mile provisioning should be based on quiet time peak rate of the cell. + +For multi-sector / multi-carrier cell sites then a statistical gain can be achieved on the last mile because it is unlikely that quiet peak time peaks will occur simultaneously on all radios. NGMA in “Guidelines for LTE Backhaul Traffic Estimation” [72] outlines a number of potential provisioning approaches for multi-sector, multi-carrier cell sites. + +- 1) Peak rate provisioning: In this case it is assumed that peak throughput occurs at the same time on all cells. NGMN point out this is a worst-case scenario and is highly unlikely to occur in practise and would be an expensive provisioning strategy. +- 2) Lower bound provisioning: This assumes peaks are uncorrelated but that the busy time mean applies to all cells simultaneously. The provisioning for N off eNBs is therefore the larger of the single cell peak or N x the busy time mean, thus: + +$$\text{Lower Provisioning Bound for } N \text{ cells} = \text{Max} (\text{peak}, N \times \text{busy time mean})$$ + +Applying this to a 3-sector D-RAN site then + +$$\text{Access (last mile) dimensioning} = \text{Max} (1 \times \text{peak}, 3 \times \text{busy time mean})$$ + +- 3) A more conservative approach assumes that whilst one cell is peaking, the others are generating traffic at the mean busy time rate, thus: + +*Conservative Lower Bound for N cells = Max [peak+(N-1) x busy time mean, N x busy time mean]* + +Applying this to a 3-sector D-RAN site then the general last mile provisioning rules is to use + +*Access (last mile) dimensioning = peak +(2 x busy time mean)* + +In Table 13 the access bandwidth needed to cater for 5G example cell sites are shown using peak quiet time provisioning for single carrier, single sector sites. For multi-carrier, multi-sector sites a comparison is made between peak rate quiet time provisioning, lower bound provisioning and conservative bound provisioning. + +| Site Type | Carrier types | Sectors | Quiet Time Peak sector rate (Mbps) | Busy time sector mean (Mbps) | | Lower provisioning bound (Gbps) | Conservative provisioning bound (Gbps) | Peak rate provisioning (Gbps) | +|-------------|---------------|---------|------------------------------------|------------------------------|--|---------------------------------|----------------------------------------|-------------------------------| +| Small (FR1) | FR1 carriers | 1 | 2020 | 606 | | N/A (single sector, carrier) | N/A (single sector, carrier) | 2.0Gbps | +| | | | | <b>Total site</b> | | <b>N/A</b> | <b>N/A</b> | <b>2.0Gbps</b> | +| | | | | | | | | | +| Small (FR2) | FR2 carriers | 1 | 3724 | 1117 | | N/A (single sector) | N/A (single sector) | 3.7Gbps | +| | | | | <b>Total site</b> | | <b>N/A</b> | <b>N/A</b> | <b>3.7Gbps</b> | +| | | | | | | | | | +| Medium | FR1 carriers | 3 | 2020 | 606 | | 2.0Gbps | 3.2Gbps | 6.1Gbps | +| | FR2 carriers | 3 | 7449 | 2234 | | 7.4Gbps | 11.9Gbps | 22.3Gbps | +| | | | | <b>Total site</b> | | <b>9.5Gbps</b> | <b>15.2Gbps</b> | <b>28.4Gbps</b> | +| | | | | | | | | | +| Large | FR1 carriers | 3 | 8078 | 2424 | | 8.1Gbps | 12.0Gbps | 24.2Gbps | +| | FR2 carriers | 3 | 14898 | 4470 | | 14.9Gbps | 23.8Gbps | 44.6Gbps | +| | | | | <b>Total site</b> | | <b>23.0Gbps</b> | <b>36.8Gbps</b> | <b>68.9Gbps</b> | + +**Table 13: Last mile provisioning for 5G Backhaul (peak, lower and conservative bound)** + +Notes: + +- 1) In this example small sites are single sector, single 5G carrier sites. With additional carriers (4G or 5G) then a statistical gain can be achieved. +- 2) Medium and large sites are 3 sector, multi-carrier 5G sites. + +- 3) Access circuit dimensioning only accounts for 5G services. 2G, 3G, 4G also needs to be considered as well. (discussed in more detail later). +- 4) Busy time mean is taken as 30% of peak quiet time rate for a sector. This number has been picked antidotally through discussions with an LTE MNO. There is on-going discussion whether this ratio will apply to a 5G NR implementations as the ratio between quiet time peak rate and busy time mean rate may change. +- 5) There is on-going discussion in the industry about whether these formula for LTE provisioning will apply in the 5G NR access circuits. +- 6) In the case of point-point last mile access technologies, the values in the table can be taken per cell. In the case of point-multipoint access technologies using a shared medium (e.g.; PON, DOCSIS), the last mile itself already performs a level of aggregation between multiple cells, and section 10.2.3.2 applies. + +#### 10.2.4.2 Pre-aggregation and aggregation transport dimensioning + +If the transport technology and the network design enable statistical multiplexing, then the initial provisioning for Backhaul in the “pre-aggregation” and the “aggregation” segments of the transport network is based on predicting the level of statistical multiplexing. This will be based on network usage, network topology, levels of aggregation at different layers and usage / traffic correlation between adjacent cell sites. + +A similar initial provisioning approach could be taken as outlined by NGMA in “Guidelines for LTE Backhaul Traffic Estimation” [72] as discussed in previous section. However, when looking at aggregated Backhaul traffic then more emphasis needs to be placed on mean busy time rates than peak rates and mean busy time rates need to be calculated across multiple cell sites not across a single site (in most situations this will push the value down). + +Longer term provisioning will be based on collecting accurate traffic matrixes at the transport layer, demand level modelling and developing capacity plans rule. + +### 10.2.5C-RAN Backhaul dimensioning + +In C-RAN architectures the access or last mile segment of the transport is not part of the Backhaul network. In these environments Backhaul dimensioning and capacity planning will be a function of the number of DUs each CU aggregates and where the CUs and UPF/UPFs resides in relation to each other and their overall position in the transport infrastructure. + +### 10.2.6Midhaul dimension + +The Midhaul RAN component is only present in C-RAN architectures Figure 5 shows two deployments of Midhaul. In the top case the O-RU, O-DU and O-CU reside as discrete entities and at different levels of the transport network. In this case the Midhaul does not span the access portion of the network. Similar considerations as outlined in C-RAN Backhaul dimensioning can be used. + +In the lower case the O-RU and O-DU are co-located in the cell site and the Midhaul runs from the cell site, across the access infrastructure to the O-CU which is located higher up in the transport network. Similar techniques as outlined in D-RAN Backhaul dimensioning can be used. + +## 10.3 Backhaul and Midhaul latency + +Previous 3GPP generations aimed at voice and basic data services. In these scenarios' user plane one-way delay between the UE and the application could be multiple 10s of milliseconds, even reaching the low hundreds of milliseconds. These figures are the delay from the UE to the destination "Application Function". + +In a 5G RAN infrastructure this is made up of: + +*Overall one-way delay = UE delay + Radio air interface delay + FH/MH/BH transport networking delay + Radio component delays (DU, CU if used) + gateway delay + GiLAN transport network delay* + +5G introduces support for different service types (eMBB, URLLC and mMTC) and aims to cover a wide range of vertical markets, such as IoT, industrial and automobile. Different services and verticals have different latency requirements, some extremely tight such as industrial motion control applications while others, such as some of IoT applications very relaxed. + +As an example, in the latest TR 22.804[85] the lowest maximum latency requirement for deterministic communication service is defined as 0.5ms for small industrial environments (50 m x 10 m x 10 m) with small packet sizes for motion control. A higher maximum latency of 500ms is given for periodic communication for standard mobile robot operation and communication services for CCTV surveillance cameras in mass rail transit with defined speeds of movement for each UE (UE speed < 50 km/h for mobile robots and ≤ 160 km/h in urban environments). + +In scenarios where low one-way latency is required then the Midhaul and Backhaul networks will need to be designed to accommodate these requirements. As the latency requirements become tighter the following needs to be considered. + +- 1) Proximity and physical path between the UE and AF +- 2) Siting of gateway and AFs in relation to each other +- 3) Delay characteristics of the physical media +- 4) Delay characteristics of the RAN components (radio, DU, CU) +- 5) Number of physical hops and delay characteristics of the switching equipment +- 6) Whether the network is a public 5G or private 5G infrastructure. + +Figure 2 illustrates how adapting the RAN architecture and placement of RAN and "Application Function" (AFs) components can change the end-to-end latency characteristics of overall 5G infrastructure. + +# 11 Transport operability + +This section concerns transport requirements to ease operability of the transport. This section includes a first sub-section about transport system requirements, a second about transceiver and port monitoring and identification of the transport equipment, a third sub-section about power saving and energy efficiency. A last sub-section concerns an optional additional interface dedicated to remote monitoring of antenna site operation. + +## 11.1 Operational transport requirements + +### 11.1.1 Transport equipment at antenna site + +It is highly desirable from the network operation perspective to manage a network transport system, i.e., the equipment at the hub site together with the equipment at the antenna site, as a single entity. In that sense, it is desirable that the equipment at the antenna site is managed via the equipment at hub site whenever possible. Therefore, transport equipment shall support real-time management and control functions of antenna site equipment by the hub site equipment. + +### 11.1.2 Dual manage transport equipment at antenna site + +The transport equipment at the antenna site shall optionally support collaborative management partition between the dedicated management by the transport equipment at hub site and also other configuration mechanisms. + +### 11.1.3 Supervision + +It is important to take care of operational expenditure dedicated to the medium of the transport and related equipment. The goal of supervision is to reduce the operational expenditure of the transport systems, without significantly increasing the capital expenditure by including as much test and diagnostic capability as possible. Naturally, this should be achieved without compromising the available bandwidth for services, i.e., test and diagnostics must be non-service affecting. + +The ability to reliably differentiate between optical medium and electrical faults at the equipment and establish if the faults are in the optical medium or in the electronics is a key operator requirement. Error inference can usually be made from the presence (i.e., power or equipment failure), or absence (i.e., fibre failure), of the Dying Gasp alarm. Several key points for the supervision can be summarized as follows: + +- optical medium monitoring/checking: Monitoring and on-demand checking the condition of optical medium independently from a transport system is important to differentiate optical medium failures from transport system failures. It is desirable that such monitoring and checking be available regardless of whether the transport equipment antenna site is in service or even connected. Several implementations could be proposed. Optical monitoring solution is proposed by ITU-T G.697 to detect anomalies, defects, degradation and fault affecting the quality of the optical transport. Another solution is to use an optical time domain reflectometer (OTDR) which is a powerful tool for diagnosing such faults in the optical medium. Power meter and light source can also be used to aid in this monitoring process. Several demarcation devices are under research for further improving the optical medium monitoring and checking. + +- transport system would benefit from an ability to automatically and autonomously detect and locate optical medium fault (optical medium segments : patch panel at the hub or antenna site, optical fiber cable in ducts or on the poles,..). +- End-to-end performance monitoring up to the Ethernet layer: End-to-end performance monitoring enables operators to diagnose and register where traffic may have been dropped or throttled. Higher layer tools, such as Ethernet performance monitoring, need to support the capability monitoring and verification of ingress and egress traffic flows in transport network elements. +- Proactive versus reactive repair: transport systems with their monitoring and control systems will allow operators to decide on the utilization of proactive or reactive fault repairs in most fault cases. It is of course up to the operators to decide on how to use transport status reports. +- For instance, key-performance-indicators related to the optical transport supervision could be made available to an orchestrator, higher in the network, through an abstraction of the optical devices through software-defined networking. + +### 11.1.4 Rogue behaviour and its mitigation in access transport segment + +This clause is largely concerned with rogue behaviour between FTTH (Fiber To The Home) based on PON (Passive Optical Network) technologies and Xhaul access transport operations in last mile optical fiber infrastructure. The transport equipment at the antenna site must be initially disabled in order to avoid disturbing PON system in case of miss-connection in the optical fiber enclosure. The antenna site transport equipment shall enable the transmitter to enter a handshaking process with hub equipment only after confirming that the frame structure and/or the line coding of the received downstream signal are matched with those the antenna site equipment complies with. This confirmation shall be done with both hub and antenna site equipment. + +The Xhaul transport equipment must support silent start operation to prevent bidirectional physical layer interfering with FTTH based on point to multi-point. The silent start means that the upstream physical layer doesn't transmit unless a valid downstream signal is received. + +### 11.1.5 Transport availability + +Operators need to determine the most resilient transport architecture for their reliable mobile services. Transport system should include a range of cost-effective resilience options to obtain the targeted availability of mobile services. These resilience schemes should be options available on the transport scenarios for passive and active equipment. Different types of service and specific offerings will require different recovery speeds. These may range from a few microseconds, for critical services like motion control for factories of the future, up to the order of seconds or minutes for monitoring or remote control applications. Note that support for resilience options should not increase the cost of such systems if deployed without resilience options. + +The protection architecture should be considered as one of the means to enhance the reliability of the Xhaul transport. However, protection shall be considered as an optional mechanism because its implementation depends on the realization of economical systems. It is also likely that other methods are used, such as cooperative technologies, e.g., fixed (optical fiber) and radio (micro-wave) for backup for cost reasons. + +Combining protection mechanisms related to Xhaul transport interfaces and the optical fiber infrastructure should even be possible, provided that the switching time of the two mechanisms is compatible or configurable. The goal should be to recover the Xhauling service in less than the common 50 ms value used for protection. + +## 11.2 Transceiver and port monitoring and identification + +### 11.2.1 Transceiver digital diagnostic monitoring + +A digital diagnostic monitoring interface for optical transceivers is used to allow access to device operating parameters. As specified in SFF-8472 and SFF-8636, data is typically retrieved from the transceiver module in a memory map of an EEPROM. Such data must be available by the data plane. With QSFP and other advanced form factor transceivers, the optical links could be multi-wavelength (4xTx & 4xRx) and/or multi-fibers (MPO - Multifiber Parallel Optic). The antenna site and hub interface management must describe a management applicable to any kind and group of media lanes. The QSFP digital diagnostic (SFF-8636) describes such media lanes. + +### 11.2.2 Transceiver class of operation for bidirectional transmission + +A plurality of transceiver modules is used today and can define operational states for pluggable form factors (like SFP, SFP+, SFP28, XFP and QSFP, QSFP+, QSFP14, QSFP28, CFP, CFP2...). Each transceiver is associated with a unique interface name and port number value. + +Concerning fiber connectivity, in the last mile network (fixed access network to reach antenna) BiDi (BiDirectional - single singlemode fiber) transceiver is the preferred implementation to simplify operation (risk of mismatch...), reduce the cost and the dimensioning of fiber cable and reduce potential path delay asymmetry. + +The interoperability between transceiver at antenna site and hub is a must. Operations at antenna site and hub must support different timeline operation, refresh and other network operations requiring different purchasers of transceivers. In order to achieve this interoperability, working classes have to be clearly identified for the required transceivers. + +### 11.2.3 Transceiver class of operation for WDM transmission + +In order to save optical fiber, wavelength division multiplexing (WDM) could be proposed. It is already the case for high bit rate transceivers (ex. 100GBase interface) with multiple wavelength per stream and per fiber. In case that Xhaul transport uses WDM transmission, a single fiber operation (bidirectional multiple wavelength) will ease network operations. This single fiber operation concerns the colorized transceiver plugged in transport equipment ports and thus sharing optical fiber infrastructure. This single fiber operation is important for the last mile fiber infrastructure to reach the antenna site. One optical fiber per stream could be also proposed. + +The wavelength assignment per port could be static or tuneable. Auto-tuneable wavelength allocation simplifies inventory management. Each wavelength channel is tuned thanks to an embedded control channel. This control channel must be interoperable to ease network operations. Similar to previous + +subsection, interoperability is a must for WDM operation and working classes (including optical spectrum parameters) have to be clearly identified. + +### 11.2.4 Port-ID to ease field operation + +In order to facilitate retrieval of the transport port identifier and other physical layer parameter indicators (ex. Launched optical power) during field operation (installation, maintenance,...), a port-ID could be tagged on the transport hub equipment. As an example, comparison of the locally measured optical power and the launched optical power information inside the port-ID should give operators a mean for measuring optical power budget. Optical monitoring and supervision parameters could refer to ITU-T G.697 for WDM systems and ITU-T G.988 for access systems based on received signal strength indicator of transceivers. + +### 11.2.5 Eye safety + +Given the higher launched optical power that can be injected into the fibre by transport equipment, both at the antenna and hub sites, all necessary mechanisms must be provided to insure that no eye damage can be caused to the end users unaware of the risks, especially if fibre is terminated inside public facilities (small cell). All transport equipment need to conform to eye safety classes. For access transport segment, the equipment must conform to the class 1M at the hub and class 1 at the antenna site defined in IEC 60825-2. + +## 11.3 Power saving and energy efficiency + +Saving energy in telecommunications network systems has become an increasingly important concern in the interest of reducing operators' operational expenses (OPEX) and the network's contribution to greenhouse gases. The power saving mechanism could be applied to reduce power consumption either continuously or during a time period. + +Transport equipment need to achieve a power saving mechanism in coordination with CORE and RAN equipment like O-CU, O-DU and O-RU. Coordination interface could be proposed to achieve such mechanism. Antenna and hub equipment may provide the best network energy efficiency experience combining both sleep periods approaches when the link is idle and line rate switching according to the actual payload to be conveyed. For the latter case, it is essential to enable the necessary logic to adapt the clock rate or number of active ports and wavelengths to the necessary payload at border equipment. + +In order to provide the most energy efficient transmission for variable traffic loads, antenna site and hub equipment must have the ability to adapt to it. As an example, transport equipment must provide a dynamic auto-negotiation of the Ethernet PHY line rate between antenna site and hub equipment and this should be enabled among the plurality of Ethernet PHY line rates supported according to the actual payload. For multi-wavelength transport (or transceiver), the number of active wavelength pair could be adapted to support the required traffic. + +Because of the high clock quality requirements, and long recovery time of clock recovery circuitry, no phase drift will be permitted in the downstream direction when switching line rate. Also, such switching will have to be hitless, i.e., without any Ethernet packet loss whatsoever. + +## 11.4 Remote monitoring antenna site operation + +The antenna tower site requires also a remote monitoring of sensors and actuator (collection of alarm, active action on site...) for environmental, power, tower light, building and facility. This remote operation requires a logical link with a master unit at the hub site or other remote site. This link could be based on Ethernet (Fast or GigaEthernet). This link should be considered by the transport system between antenna site and hub site. + +## 11.5 Operability requirements + +Table 14 captures operability transport requirements. + +| Capability | Requirements | Notes | +|-----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------| +| Management | The transport equipment at the antenna site MAY be managed via the transport equipment at the hub site. | | +| Supervision | The transport equipment supervision MUST differentiate equipment and infrastructure faults. | | +| Rogue behaviour | For access network segment, the transport equipment at antenna site MUST support mechanism to avoid disturbing other network operations like silent start network function | This requirement allows to prevent jamming transmission on the FTTH networks in cases of unintentional connection. | +| Availability | Operator MAY choose to use resilience mechanism for transport equipment and infrastructure. | Technology solution to meet this requirement will be covered based on coordination with CORE and RAN equipment. | +| Transceiver | The transport equipment MUST provide the digital diagnostic data of transceivers. The interoperability between transceivers at antenna site and hub is a MUST. Operator MAY choose to select bidirectional (single fiber) to ease operation. In case of WDM transport equipment, operator MAY choose auto-tunable wavelength transceivers. | | +| Port ID | For antenna site operation, optical monitoring and supervision parameters MUST be supported for remote operations. | | +| Eye safety | The transport equipment for access segment MUST be conform to the class 1M at the hub and class 1 at the antenna site defined in IEC 60825-2 | | + +| | | | +|--------------------------------|----------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------| +| Power saving energy efficiency | The transport equipment MUST be capable to support power saving mechanism. | Technology solution to meet this requirement will be covered based on coordination with CORE and RAN equipment. | +|--------------------------------|----------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------| + +**Table 14: Operability transport requirements** + +# 12 Synchronization + +This chapter spells out synchronization requirements for fronthaul networks in alignment with WG CUS specification [74]. + +## 12.1 Frequency, Phase and Time Accuracy Requirements + +The following set of synchronization requirements have been identified as relevant for O-RAN: + +- Radio frame alignment (O-RU radio interface) + - Absolute sync to support TDD : relative $3\mu\text{s}$ between antennas is transformed into $\pm 1.5\mu\text{s}$ with regarding to a common reference(e.g. GNSS) + - Relative sync to support radio coordination functions. Most stringent requirement between “non-collocated” O-RUs is 260 ns TAE. Other applicable requirements are $3\mu\text{s}$ (to support TDD networks). In case of co-located O-RUs 130 ns may also apply. +- Control of the latency between O-DU and O-RU (section 2.3 from O-RAN CUS specification): + - The relative time error between the O-DU and O-RU shall be within a limit of $3\mu\text{s}$ ( $\pm 1.5\mu\text{s}$ ). This requirement applies whether the O-DU is on the synchronization path towards O-RU or not. +- O-DU to O-DU synchronization for Radio Frames handling (e.g., SFN generation): + - Expected in the ms range +- Frequency sync of the radio signal + - Frequency accuracy/stability of the O-RU radio interface (50 / 100 ppb) +- O-CU to O-DU synchronization + - No stringent requirement identified (alarm timestamping is one possible use case) + +Further details are provided below for some of these requirements. + +The frequency synchronization requirements are summarized in Table 15. + +| Application/<br>Technology | Frequency Accuracy Requirements | Specification | +|----------------------------|---------------------------------|---------------------------------------------| +| LTE Wide Area BS | $\pm 0.05$ ppm | 3GPP TS 36.104 (01/2020) [75] section 6.5.1 | +| LTE Medium Range BS | $\pm 0.1$ ppm | 3GPP TS 36.104 (01/2020)[75] section 6.5.1 | +| LTE Local Area BS | $\pm 0.1$ ppm | 3GPP TS 36.104 (01/2020) [75] section 6.5.1 | +| LTE Home BS | $\pm 0.25$ ppm | 3GPP TS 36.104 (01/2020 [75] section 6.5.1 | +| NR Wide Area BS | $\pm 0.05$ ppm | 3GPP TS 38.104 (01/2020) [76] section 6.5.1 | +| NR Medium Range BS | $\pm 0.1$ ppm | 3GPP TS 38.104 (01/2020) [76] | + +| | | | +|------------------|----------|------------------------------------------------| +| | | section 6.5.1 | +| NR Local Area BS | ±0.1 ppm | 3GPP TS 38.104 (01/2020) [76]<br>section 6.5.1 | + +**Table 15: Frequency Accuracy Requirements** + +### **Time/Phase synchronization requirements:** + +The requirements for Time/Phase synchronization for LTE features and 5G features covered in WG4 CUS specification [74] can be referenced as described below: + +- Table 9-1: LTE features with time alignment error requirement at the air interface +- Table 9-2: 5G features with time alignment error requirement + +## 12.2 Error Budget Allocation Requirements + +In case of LLS-C1 and LLS-C2 the frequency error budget allocation can be based on Table 9-3 of ORAN-WG4.CUS.0-v03.00 (04/2020) [74]. + +In case of LLS-C3 the frequency error budget allocation is provided in Table 16 and is based on Table 9-4 of ORAN-WG4.CUS.0-v03.00 (04/2020) [74]. + +| Timing Reference | O-RAN transport network contribution limit (LLS-C3) | +|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------| +| PRTC | MTIE per ITU-T G.8272/Y.1367 (11/2018) [82] clause 6.2 | +| ePRTC | MTIE per ITU-T G.8272.1/ Y.1367.1 (08/2019) [79] clause 6.2 | +| PRTC in holdover | FFS (Note 1) | +| ePRTC in holdover | <100ns for 14 days per G.8272.1 clause 8.2 | +| Note 1: PRTC holdover is for further study. As an example, G.8271.1 (08/2019) Annex V.3 Failure scenarios, refers to a holdover failure scenario of 400 ns for a short interruption (e.g. 5 min) of GNSS. This could be extended to longer periods (e.g. several hours or longer) depending on choice of oscillator and system design. | | + +**Table 16: Wander generation requirement for PRTC/ePRTC** + +ITU-T G.8272/Y.1367 (11/2018): **Timing characteristics of primary reference time clocks** +<https://www.itu.int/rec/T-REC-G.8272-201811-I/en> + +ITU-T G.8272.1/Y.1367.1 (11/2016) Amendment 2 (08/2019): Timing characteristics of enhanced primary reference time clocks +<https://www.itu.int/rec/T-REC-G.8272.1-201908-I!Amd2/en> + +### ITU-T G.8271.1/Y.1366 (2017) Amendment 2 (08/2019) : Network limits for time synchronization in packet networks + +<https://www.itu.int/rec/T-REC-G.8271.1-201908-S!Amd2/en> + +For the case of LLS-C1 and LLS-C2 the time error budget allocation is summarized Table 17 and is based on Table 9-3 of ORAN-WG4.CUS.0-v03.00 (04/2020) [74]. Two types of O-RU are considered in the CUS specification: *Enhanced* O-RU with $|\text{TE}| < 35$ ns and *Regular* O-RU with $|\text{TE}| < 80$ ns. + +The below table considers a time error budget allocation model from Xhaul transport point of view from end to end Grandmaster to O-RU. Here it is simplified to show the transport network budget based on different PRTC/GM and type of O-RU selected for the entire Xhaul network. + +| Time error budget allocation (LLS-C1/C2) | | | | +|----------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------| +| Timing Reference | O-RAN transport network contribution limit (NOTE2) | O-RU | Air interface target | +| No relative $ \text{TE} $ contribution by PRTC/T-GM since PRTC/T-GM is common PTP and SyncE master to all co-operated O-RU | Relative $ \text{TE}_L \leqslant 60\text{ns}$<br>Between 2 =-RUs UNI<br>Note 1<br>Note 2 | <i>Enhanced</i> O-RU<br><br><i>NOTE- regular O-RU can't meet this requirement</i> | 130ns $ \text{TAE} $ between antennas<br><br>For NR Intra-band contiguous carrier aggregation (FR2) | +| | Relative $ \text{TE}_L \leqslant 190\text{ns}$<br>Between 2 O-RUs UNI<br>Note 1<br>Note 2 | <i>Enhanced</i> O-RU | 260ns TAE between antennas<br><br>For NR Intra-band contiguous carrier aggregation (FR1) | +| | Relative $ \text{TE}_L \leqslant 100\text{ns}$<br>Between 2 O-RUs UNI<br>Note 1<br>Note 2 | <i>Regular</i> O-RU (Note 4) | | +| Absolute $ \text{TE} \leqslant 100\text{ns}$<br>PRTC-A/T-GM spec per ITU-T | Network $ \text{TE}_L \leqslant 1365\text{ns}$<br>• Between T-GM port and O-RU UNI | <i>Enhanced</i> O-RU | 3 $\mu$ s TAE between antennas (TDD, NR Inter-band carrier) | + +| | | | | +|----------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------|----------------------|------------------------------------------------------------------| +| G.8272 (03/2020)<br>[78] | Network $ \text{TE}_L \leqslant 1320\text{ns}$<br>• Between T-GM port and O-RU UNI | <i>Regular O-RU</i> | aggregation or NR Intra-band non-contiguous carrier aggregation) | +| Absolute $ \text{TE} \leqslant 30\text{ns}$<br>ePRTC/T-GM spec per ITU-T G.8272.1 (08/2019) [79] | Network $ \text{TE}_L \leqslant 1435\text{ns}$<br>• Between T-GM port and O-RU UNI | <i>Enhanced O-RU</i> | | +| | Network $ \text{TE}_L \leqslant 1390\text{ns}$<br>• Between T-GM port and O-RU UNI | <i>Regular O-RU</i> | | +| Absolute $ \text{TE} \leqslant 40\text{ns}$<br>PRTC-B/T-GM spec per ITU-T G.8272.1 (08/2019) [79] | Network $ \text{TE}_L \leqslant 1425\text{ns}$<br>• Between T-GM port and O-RU UNI | <i>Enhanced O-RU</i> | | +| | Network $ \text{TE}_L \leqslant 1380\text{ns}$<br>• Between T-GM port and O-RU UNI | <i>Regular O-RU</i> | | + +**Table 17: Time Error Budget Allocation** + +Note 1 – Further details are being defined by ITU-T. + +Note 2 – Examples for allocation of time error are provided in Section 12.4. + +Note 3 – In general the table-16 describes the time error allocation break out for network versus end device requirement. The simple breakout model can be described as + +$\text{GM/GNSS} + \text{Network} + \text{End device (O-RU)} = \text{Total budget.}$ + +Note 4 – Regular O-RU refers to Class-B O-RU as per ORAN-WG4.CUS.0-v03.00 (04/2020) [74]. + +The time error budget allocation for the case of LLS-C3 is specified by ITU-T G.8271.1 (03/2020) [77]. + +## 12.3 Synchronization solution requirements + +Successful synchronization deployment depends on many factors. A solution architecture document for timing and synchronization will cover more in detail the following aspects: + +- Building blocks of network based synchronization +- Timing profiles + +- Synchronization time error budgeting models +- Synchronization network models - factors to be considered +- Other applications and sync model +- Synchronization network monitoring and management models +- Best practices and network models + +## 12.4 Summary + +In summary, the use of Precision Timing Protocol (PTP) has been in use for many network iterations. With the migration to NR and eCPRI, it will become more prevalent and have an extended reach in mobility networks, all the way to the O-RU. This will require a PTP profile based on ITU-T G.8275.1 (03/2020) [80] with Synchronous Ethernet, in the Fronthaul, from O-DU to O-RU (note: for the O-RU it is optional the use of SyncE). The Technical Solutions Document will further describe options for the enhancing the network synchronization performance and reliability. + +Finally, Figure 14 to Figure 16 provide some examples of absolute and relative time error requirements as diagrams for LLS-C1 and LLS-C2. + +Config LLS-C3 is being studied in ITU-T (planned to be covered in ITU-T G.8271.1 (03/2020) [77]) + +![Figure 14: Example of Absolute vs Relative Requirements (Config LLS-C1 Option A, where T-GM is embedded in O-DU). The diagram illustrates synchronization requirements between a distribution site (A) and two remote sites (C). The distribution site contains an O-DU with a T-GM and a PRTC. The remote sites contain O-RUs (enhanced or regular) with T-TSCs. Various time error budgets (TAE) are shown for different scenarios, including (FR1), (FR2), and (eO-RU).](d6e77ba812ff8ede90f1f0a589f61674_img.jpg) + +Figure is for illustrative purpose and does not provide deployment guidance. + +The diagram shows two distribution sites (A and B) and two remote sites (C). Site A contains an O-DU with a T-GM and a PRTC. Site B contains an O-DU with a PRTC and a T-GM. Site C contains two remote sites, each with an O-RU (enhanced or regular) and a T-TSC. The diagram illustrates various time error budgets (TAE) for different scenarios, including (FR1), (FR2), and (eO-RU). The TAE values are shown in ns. + +The budgeting examples are based on the conservative assumption of linear accumulation between the 2 branches relevant to the TAE requirement. + +Legend: + +- (FR1): NR intra-band continuous carrier aggregation in FR1 +- (FR2): NR intra-band continuous carrier aggregation in FR2 (co-located RUs only) +- (eO-RU): enhanced O-RU +- (rO-RU): regular O-RU + +Figure 14: Example of Absolute vs Relative Requirements (Config LLS-C1 Option A, where T-GM is embedded in O-DU). The diagram illustrates synchronization requirements between a distribution site (A) and two remote sites (C). The distribution site contains an O-DU with a T-GM and a PRTC. The remote sites contain O-RUs (enhanced or regular) with T-TSCs. Various time error budgets (TAE) are shown for different scenarios, including (FR1), (FR2), and (eO-RU). + +**Figure 14: Example of Absolute vs Relative Requirements (Config LLS-C1 Option A, where T-GM is embedded in O-DU)** + +![Figure 15: Example of Absolute vs Relative Requirements (Config LLS-C1 Option B, where T-GM is directly connected to O-DU).](a680d1afaa17f8858741dddaec748092_img.jpg) + +Figure 15 illustrates the timing requirements for Config LLS-C1 Option B, where the T-GM is directly connected to the O-DU. The diagram is divided into five sections: A, B, C, D, and E. + +- Section A:** Shows the PRTC/ePRTC T-GM with timing requirements: PRTCA [ITE] ≤ 100 ns, PRTCB [ITE] ≤ 40 ns, and ePRTC [ITE] ≤ 30 ns. +- Section B:** Shows the PTP/SyncE path from the T-GM to the nearest common BC (distribution site). The timing budget is ±30...100 ns. The budgeting examples are based on the conservative assumption of linear accumulation between the 2 branches relevant to the TAE requirement. +- Section C:** Shows the nearest common BC (distribution site) connected to the remote site. The remote site contains O-RU (enhanced) and O-RU (regular) with T-TSCs. The timing budget for the remote site is ±50 ns for (FR1) and ±130 ns for (FR2). +- Section D:** Shows the timing requirements for the remote site. The timing budget for the remote site is ±50 ns for (FR1) and ±130 ns for (FR2). +- Section E:** Shows the ITU-T G.8271 TAE requirements. The timing budget for the remote site is ±50 ns for (FR1) and ±130 ns for (FR2). + +The diagram also includes a legend for the remote site components: (FR1): NR intra-band continuous carrier aggregation in FR1, (FR2): NR intra-band continuous carrier aggregation in FR2 (co-located RUs only), (eO-RE): enhanced O-RU, and (rO-RU): regular O-RU. + +Figure 15: Example of Absolute vs Relative Requirements (Config LLS-C1 Option B, where T-GM is directly connected to O-DU). + +Figure 15: Example of Absolute vs Relative Requirements (Config LLS-C1 Option B, where T-GM is directly connected to O-DU) + +![Figure 16: Example of Absolute vs Relative Requirements (Config LLS-C2 Option A, where O-DU is nearest common T-BC).](ac4bedf643144de4de6f005512c7b895_img.jpg) + +Figure 16 illustrates the timing requirements for Config LLS-C2 Option A, where the O-DU is the nearest common T-BC. The diagram is divided into five sections: A, B, C, D, and E. + +- Section A:** Shows the PRTC/ePRTC T-GM with timing requirements: PRTCA [ITE] ≤ 100 ns, PRTCB [ITE] ≤ 40 ns, and ePRTC [ITE] ≤ 30 ns. +- Section B:** Shows the PTP/SyncE path from the T-GM to the nearest common BC (distribution site). The timing budget is ±30...100 ns. The budgeting examples are based on the conservative assumption of linear accumulation between the 2 branches relevant to the TAE requirement. +- Section C:** Shows the nearest common BC (distribution site) connected to the remote site. The remote site contains O-RU (enhanced) and O-RU (regular) with T-TSCs. The timing budget for the remote site is ±50 ns for (FR1) and ±130 ns for (FR2). +- Section D:** Shows the timing requirements for the remote site. The timing budget for the remote site is ±50 ns for (FR1) and ±130 ns for (FR2). +- Section E:** Shows the ITU-T G.8271 TAE requirements. The timing budget for the remote site is ±50 ns for (FR1) and ±130 ns for (FR2). + +The diagram also includes a legend for the remote site components: (FR1): NR intra-band continuous carrier aggregation in FR1, (FR2): NR intra-band continuous carrier aggregation in FR2 (co-located RUs only), (eO-RE): enhanced O-RU, and (rO-RU): regular O-RU. + +Figure 16: Example of Absolute vs Relative Requirements (Config LLS-C2 Option A, where O-DU is nearest common T-BC). + +Figure 16: Example of Absolute vs Relative Requirements (Config LLS-C2 Option A, where O-DU is nearest common T-BC) + +- 1 Note: All three figures (14, 15 and 16), the T-TSC embedded in remote site and T-BC embedded in +- 2 O-DU need not to be compliance to ITU-T G.8273.2, 03/2020 [81] specification. Refer the WG4 +- 3 CUS spec [74] for additional details on this. + +# 13 Legacy Requirements + +Legacy radio equipment plays a role in the 5G network evolution and must be supported in the new network implementations. This means support of the Common Public Radio Interface (CPRI) must be taken into consideration as it is the interface between radios and BBU. As stated in the Scope section, legacy transport will follow 3GPP split Option 8, the PHY-RF split. This option allows to separate the RF and the PHY layer. In addition, it allows for centralization of processes at all protocol layer levels, resulting in very tight coordination of the RAN and provides efficient support of functions such as CoMP, MIMO, and load balancing. + +CPRI is a digitized and serial interface that establishes a connection between BBU and an RRH. The BBU contains the radio functions of the digital baseband domain and the radio contains the analog radio frequency functions. CPRI supports three information flows: + +1. IQ Data – user plane information in the form of In-Phase and Quadrature modulation data +2. C&M Data – Control and Management data which is exchanged between the “REC” and “RE” +3. Synchronization Data – used for CPRI frame and time alignment + +The three CPRI information flows are supported separately with a flow of frames supporting the IQ data information flow and a flow supporting the C&M data. Synchronization is provided separately. + +The Table 18 below breaks out the different requirements for each flow: + +| Plane/CPRI Flow | Latency (RTT) | Frame Loss Ratio | Traffic Type Repartition | Traffic Pattern | Traffic QoS | +|-----------------|---------------|------------------|--------------------------|-------------------|-------------| +| IQ Data | 125 $\mu$ s | $10^{-7}$ | >90% | Constant Bit Rate | High | +| C&M Data | n/a | $10^{-6}$ | <10% | Burst | Best Effort | +| Synchronization | n/a | n/a | n/a | n/a | Very High | + +**Table 18: CPRI Flow Requirements** + +For legacy LTE radios, the Fronthaul bandwidth reference for CPRI traffic is classified in Table 19 + +| | number of sectors | Total CBW (MHz) | MIMO layers | ABW (MHz) | FH BW (Gbps) | +|--------|-------------------|-----------------|-------------|-----------|--------------| +| Small | 1 | 40 | 4 | 160 | 10 | +| Medium | 3 | 40 | 4 | 480 | 29 | +| Large | 3 | 80 | 4 | 960 | 59 | + +**Table 19: Fronthaul Bandwidth Reference for LTE traffic in CPRI** + +For CPRI rate calculation associated with option 8 split, + +$$\text{FH BW} = 2 \cdot 10^{-9} \cdot 1.25 \cdot f_s \cdot N_{bit} \cdot N_{ant} \text{ (Gbps)}$$ + +Where + +- $f_s$ is the sample frequency, and $f_s = 30.72$ MHz for 20MHz LTE carriers +- 1.25 is the increasing factor due to the overhead from 8b/10b line code. When 66b/64b line code is used, this factor should be changed to $66/64=1.03125$ +- $\frac{16}{15}$ is the CPRI control word overhead +- $N_{bit}$ is the bitwidth of the radio I/Q sample +- $N_{ant}$ is the number of antennas + +Unlike eCPRI, the CPRI traffic will be constant regardless the user data payload. If CPRI interface is not efficiently used (such as empty AxCs in the CPRI Basic Frame) the required Fronthaul bandwidth will be expected higher. + +For co-existence of the 5G NR and LTE radios in the same cell site, both eCPRI and CPRI traffic should be considered. Combining the results given in section 7.2 for eCPRI traffic, Table 20 gives the total Fronthaul bandwidth reference with both eCPRI and CPRI traffic included. + +| | CPRI | | eCPRI | | Total FH<br>BW (Gbps) | +|--------|------|-------|-------|-------|-----------------------| +| | ABW | FH BW | ABW | FH BW | | +| Small | 160 | 10 | 800 | 15 | 24 | +| Medium | 480 | 29 | 6000 | 110 | 140 | +| Large | 960 | 59 | 14400 | 265 | 324 | + +**Table 20: Fronthaul Bandwidth Reference for eCPRI + CPRI** + +For specific RAN equipment implementation, the RAN split point may not be O-RAN option7-2x. So, different RAN vendors have different results due to different implementation details and parameter settings. Taking the following split choice as an example: + +- Downlink User Plane: option 7-3, +- Uplink User Plane: Between “Resource Element De-Mapping” and “Channel estimation”; + +Table 21 provides the bandwidth calculation based on the split point shown above and with both eCPRI and CPRI traffic included. + +| | Number of sectors | CBW (MHz) | MIMO Layers | $\mu$ | ABW (MHz) | Frequency Band | Fronthaul Interface | Air Interface | FH BW (GHz) | Example FH Interface | +|-----------|-------------------|-----------|-------------|-------|-----------|----------------|---------------------|---------------|---------------|----------------------| +| Carrier 1 | 3 | 100 | 16 | 1 | 4800 | 2.6GHz | eCPRI | NR | 68.4(22.8*3) | 3*25G eCPRI | +| Carrier 2 | 3 | 60 | 16 | 1 | 2880 | 2.6GHz | eCPRI | NR | 42.2(14.06*3) | 3*25G eCPRI | + +**Table 21: Large site configuration, Sub 6 NR(massive MIMO)** + +# Annex A Fronthaul Bandwidth Calculation + +This section provides more details for the bandwidth calculation in 7.2 with site carrier configuration examples. Different types of deployments can occur in practice; single-RAT (e.g. 5G fronthaul) versus multi-RAT (e.g. LTE CPRI + 5G fronthaul), pure front- or mid- or backhaul versus a mix of different of X-haul cases. The examples in Table 22 to Table 26 illustrate different cases and different combinations thereof. + +Given below are the parameter settings in evaluating the Fronthaul bandwidth via the equation provided in section 7.2 for 7-2x split based eCPRI: + +- $N_{PRB} = 264, \mu = 3$ for 400MHz mmWave carriers [3GPP 38.101] +- $N_{PRB} = 273, \mu = 1$ for 100MHz Sub 6 carriers [3GPP 38.101] +- $N_{mantissa} = 9$ +- $N_{exponent} = 4$ + +With about settings, a 400MHz mmWave carrier with 2 layer MIMO is found to have 14.96Gbps FH BW and 100MHz Sub 6 carrier with 4 layer MIMO being 7.74Gbps. + +According to the BW calculation equation provided in section 13 the parameters are set as + +- $N_{bit}=15$ +- $f_s = 30.72$ MHz + +Thus for a 20MHz LTE carrier with 2 antenna branches, the CPRI rate is found to be 2.46 Gbps, which is the typical CPRI-3 line rate. + +The carrier setting examples are illustrated in Table 22 to Table 26, for small, medium, and large scenarios respectively. The Fronthaul BW for each carrier is aggregated over all sectors and is reported in FH BW column. For the purpose of reference, the optical interfaces to the radios for all sectors are provided at last Colum. Note that these FH interfaces are only exemplary. Actual interface configuration may vary depending on the radio designs from different vendors. For example, if carrier 2 and 3 is cascaded, the resulting transport can be carried by a CPRI 7 link. + +Small Examples: + +| | number of sectors | CBW (MHz) | MIMO Layers | $\mu$ | ABW (MHz) | Frequency Band | Fronthaul Interface | Air Interface | FH BW (Gbps) | Example FH Interface | +|-----------|-------------------|-----------|-------------|-------|-----------|----------------|---------------------|---------------|--------------|----------------------| +| carrier 1 | 1 | 400 | 2 | 3 | 800 | 39GHz | eCPRI | NR | 14.57 | 1x25G eCPRI | +| carrier 2 | 1 | 20 | 4 | | 80 | B-2 | CPRI | LTE | 4.92 | 1xCPRI5 | +| carrier 3 | 1 | 20 | 4 | | 80 | B-4 | CPRI | LTE | 4.92 | 1xCPRI5 | +| Total | | | | | | | | | 24.40 | | + +**Table 22: Small site configuration, LTE + mmWave NR** + +| | number<br>of sectors | CBW<br>(MHz) | MIMO<br>Layers | $\mu$ | ABW<br>(MHz) | Frequency<br>Band | Fronthaul<br>Interface | Air<br>Interface | FH BW<br>(Gbps) | Example FH<br>Interface | +|-----------|----------------------|--------------|----------------|-------|--------------|-------------------|------------------------|------------------|-----------------|-------------------------| +| carrier 1 | 1 | 100 | 4 | 1 | 400 | C-band | eCPRI | NR | 7.5 | 1x10G eCPRI | +| carrier 2 | 1 | 20 | 4 | | 80 | B-2 | CPRI | LTE | 4.9 | 1xCPRI5 | +| carrier 3 | 1 | 20 | 4 | | 80 | B-4 | CPRI | LTE | 4.9 | 1xCPRI5 | +| Total | | | | | | | | | 17.4 | | + +**Table 23: Small site configuration, LTE+Sub 6 NR:** + +Medium Examples: + +| | number<br>of sectors | CBW<br>(MHz) | MIMO<br>Layers | $\mu$ | ABW<br>(MHz) | Frequency<br>Band | Fronthaul<br>Interface | Air<br>Interface | FH BW<br>(Gbps) | Example FH<br>Interface | +|-----------|----------------------|--------------|----------------|-------|--------------|-------------------|------------------------|------------------|-----------------|-------------------------| +| carrier 1 | 3 | 400 | 4 | 3 | 4800 | 39GHz | eCPRI | NR | 87.4 | 6x25G eCPRI | +| carrier 2 | 3 | 100 | 4 | 1 | 1200 | C-band | eCPRI | NR | 22.6 | 3x10G eCPRI | +| carrier 3 | 3 | 20 | 4 | | 240 | B-2 | CPRI | LTE | 14.7 | 3xCPRI5 | +| carrier 4 | 3 | 20 | 4 | | 240 | B-4 | CPRI | LTE | 14.7 | 3xCPRI5 | +| Total | | | | | | | | | 139.5 | | + +**Table 24: Medium site configuration, LTE + Sub 6 NR + mmWave NR** + +| | number<br>of sectors | CBW<br>(MHz) | MIMO<br>Layers | $\mu$ | ABW<br>(MHz) | Frequency<br>Band | Fronthaul<br>Interface | Air<br>Interface | FH BW<br>(Gbps) | Example FH<br>Interface | +|-----------|----------------------|--------------|----------------|-------|--------------|-------------------|------------------------|------------------|-----------------|-------------------------| +| carrier 1 | 3 | 100 | 16 | 1 | 4800 | C-Band | eCPRI | NR | 90.4 | 6x25G eCPRI | +| carrier 2 | 3 | 20 | 4 | | 240 | B-2 | CPRI | LTE | 14.7 | 3xCPRI5 | +| carrier 3 | 3 | 20 | 4 | | 240 | B-4 | CPRI | LTE | 14.7 | 3xCPRI5 | +| Total | | | | | | | | | 119.9 | | + +**Table 25: Medium site configuration, LTE + Sub 6 NR (massive MIMO)** + +Large Example: + +| | number<br>of sectors | CBW<br>(MHz) | MIMO<br>Layers | $\mu$ | ABW<br>(MHz) | Frequency<br>Band | Fronthaul<br>Interface | Air<br>Interface | FH BW<br>(Gbps) | Example FH<br>Interface | +|-----------|----------------------|--------------|----------------|-------|--------------|-------------------|------------------------|------------------|-----------------|-------------------------| +| carrier 1 | 3 | 400 | 4 | 3 | 4800 | 39GHz | eCPRI | NR | 87.4 | 6x25G eCPRI | +| carrier 2 | 3 | 400 | 4 | 3 | 4800 | 24GHz | eCPRI | NR | 87.4 | 6x25G eCPRI | +| carrier 3 | 3 | 100 | 16 | 1 | 4800 | C-band | eCPRI | NR | 90.4 | 6x25G eCPRI | +| carrier 4 | 3 | 20 | 4 | | 240 | B-2 | CPRI | LTE | 14.7 | 3xCPRI5 | +| carrier 5 | 3 | 20 | 4 | | 240 | B-4 | CPRI | LTE | 14.7 | 3xCPRI5 | +| carrier 6 | 3 | 20 | 4 | | 240 | B-30 | CPRI | LTE | 14.7 | 3xCPRI5 | +| carrier 7 | 3 | 20 | 4 | | 240 | B-66 | CPRI | LTE | 14.7 | 3xCPRI5 | +| Total | | | | | | | | | 324.2 | | + +**Table 26: Large site configuration, LTE + Sub 6 NR (massive MIMO) + mmWave NR** + +Note that the FH interfaces provided in last column are only exemplary. Actual interface configuration may vary depending on the radio designs from different vendors. For example, if carrier 2 and 3 is cascaded, the resulting transport can be carried by a CPRI 7 link. + +# Annex B: Slicing in Backhaul and Midhaul + +Network slicing is a key component of the 5G architecture. It is an end to end capability and a “Network Slice Instances” (NSIs) covers multiple “Network Subnet Slices Instances” (NSSIs) including the “Access Network” or radio network, the mobile “Core Network” (CN) and the “Transport Network”. (TN) + +Figure 17 shows the relationship between NSIs and NSSIs. These can be: + +- 1) 1:1: Each NSI utilises has its own NSSIs which is not shared with other NSIs. +- 2) n:m: NSIs share NSSIs. For example, an NSI has a dedicated access NSSI but uses a shared mobile core NSSI, or multiple NSIs have dedicated access and core NSSIs but use a common transport NSSI. + +![Diagram illustrating NSI to NSSI relationships across AN, TN, and CN layers.](88d27ce2c438a3cc1c6a11ddc2ba5824_img.jpg) + +The diagram illustrates three scenarios of Network Slice Instance (NSI) to Network Subnet Slice Instance (NSSI) relationships across three layers: Access Network (AN), Transport Network (TN), and Core Network (CN). + +- Scenario 1 (1:1):** A single green line representing an NSI connects a dedicated green antenna in the AN, a green cloud in the TN, and a single green box labeled "5G Core" in the CN. +- Scenario 2 (n:m):** Multiple colored lines (blue, orange, yellow) representing different NSIs share resources. In the AN, there are multiple antennas. In the TN, there are multiple clouds. In the CN, these lines converge into a single blue box labeled "5G Core". +- Scenario 3 (n:m):** Multiple colored lines (red, grey) representing different NSIs share resources. In the AN, there are multiple antennas. In the TN, there are multiple clouds. In the CN, these lines converge into two separate boxes, one red labeled "5G Core" and one grey labeled "5G Core". + +A large bracket on the right side of the diagram groups the second and third scenarios under the label n:m. + +Diagram illustrating NSI to NSSI relationships across AN, TN, and CN layers. + +**Figure 17: NSI to NSSI relationships (Source: Cisco)** + +The transport infrastructure needs to be able to account for these different eventualities and allow: + +- 1) The transport NSSI to be completely closed. In this case only components connected to the transport NSSI can communicate with each other at the IP level. + +- 2) The transport NSSI is partially closed. In this case components connected to the transport NSSI can communicate with each other at the IP layer but also communicate with entities that are shared between NSIs. For example, a common AMF or other mobile core components used by multiple slices. +- 3) Controlled connectivity within a transport NSSI. In this case components connected to same transport NSSI have their IP communication controlled to other entities within the same transport NSSI. For example, radio access components within the slice can communicate with each other and with all UPFs, but UPFs owned by different customers cannot communicate with each other across the transport NSSI. + +Transport slicing is a required capability within the Backhaul network. Figure 18 shows a high-level example of a transport NSSI in a D-RAN architecture and Figure 19 shows a similar example of a transport network NSSI in a C-RAN architecture. Figure 20 shows further detail of an NSSI supporting purely Backhaul and how that an NSSI can have different VPNs for different functions. + +![Figure 18: Transport Network NSSI in a D-RAN architecture. The diagram shows a central 'Backhaul' cloud (green) connected to three data centers: 'Far Edge DC', 'Edge DC', and 'Regional DC'. The 'Regional DC' contains a 'UPF' (User Plane Function) and is connected to an 'N6' cloud (yellow). The 'Central DC' is connected to the 'Backhaul' cloud and contains 'Common 3GPP control Plane components' and 'Per slice SMFs'. Three 'RU' (Radio Units) are connected to the 'Backhaul' cloud.](0848d5c69822ed0a09380bccedd82457_img.jpg) + +Figure 18: Transport Network NSSI in a D-RAN architecture. The diagram shows a central 'Backhaul' cloud (green) connected to three data centers: 'Far Edge DC', 'Edge DC', and 'Regional DC'. The 'Regional DC' contains a 'UPF' (User Plane Function) and is connected to an 'N6' cloud (yellow). The 'Central DC' is connected to the 'Backhaul' cloud and contains 'Common 3GPP control Plane components' and 'Per slice SMFs'. Three 'RU' (Radio Units) are connected to the 'Backhaul' cloud. + +**Figure 18: Transport Network NSSI in a D-RAN architecture. Transport NSSI is two discrete networks (Source: Cisco)** + +![Figure 19: Transport Network NSSI in a C-RAN architecture. The diagram shows a cloud-based network architecture. On the left, three RU (Radio Units) are connected to a red cloud labeled 'Fronthaul'. The 'Fronthaul' cloud connects to a blue cloud labeled 'Midhaul'. The 'Midhaul' cloud connects to a green cloud labeled 'Backhaul'. The 'Backhaul' cloud connects to a yellow cloud labeled 'N6'. Below the clouds, there are three DC (Data Center) blocks: 'Far Edge DC' containing an 'O-DU' block, 'Edge DC' containing an 'O-CU' block, and 'Regional DC' containing a 'UPF' block. A 'Central DC' block is located at the top right, containing 'Common 3GPP control Plane components' and 'Per slice SMFs'. The 'Central DC' is connected to the 'N6' cloud and the 'UPF' block in the 'Regional DC'.](0a6ee8b1e244b412fcbb3b2e9c5bc240_img.jpg) + +Figure 19: Transport Network NSSI in a C-RAN architecture. The diagram shows a cloud-based network architecture. On the left, three RU (Radio Units) are connected to a red cloud labeled 'Fronthaul'. The 'Fronthaul' cloud connects to a blue cloud labeled 'Midhaul'. The 'Midhaul' cloud connects to a green cloud labeled 'Backhaul'. The 'Backhaul' cloud connects to a yellow cloud labeled 'N6'. Below the clouds, there are three DC (Data Center) blocks: 'Far Edge DC' containing an 'O-DU' block, 'Edge DC' containing an 'O-CU' block, and 'Regional DC' containing a 'UPF' block. A 'Central DC' block is located at the top right, containing 'Common 3GPP control Plane components' and 'Per slice SMFs'. The 'Central DC' is connected to the 'N6' cloud and the 'UPF' block in the 'Regional DC'. + +**Figure 19: Transport Network NSSI in a C-RAN architecture. Transport NSSI is 4 discrete networks** + +![Figure 20: More details on the Transport Network NSSI in a D-RAN architecture. The diagram shows a cloud-based network architecture. On the left, three RU (Radio Units) are connected to a green cloud labeled 'Backhaul Control Plane (N1, N3, N4)'. The 'Backhaul Control Plane' cloud connects to a green cloud labeled 'Backhaul User Plane (N3, N9)'. The 'Backhaul User Plane' cloud connects to a yellow cloud labeled 'N6'. Below the clouds, there are three DC (Data Center) blocks: 'Far Edge DC', 'Edge DC', and 'Regional DC' containing a 'UPF' block. A 'Central DC' block is located at the top right, containing 'Common 3GPP control Plane components' and 'Per slice SMFs'. The 'Central DC' is connected to the 'N6' cloud and the 'UPF' block in the 'Regional DC'.](8983c35605cf074e2b23b179a8671f2b_img.jpg) + +Figure 20: More details on the Transport Network NSSI in a D-RAN architecture. The diagram shows a cloud-based network architecture. On the left, three RU (Radio Units) are connected to a green cloud labeled 'Backhaul Control Plane (N1, N3, N4)'. The 'Backhaul Control Plane' cloud connects to a green cloud labeled 'Backhaul User Plane (N3, N9)'. The 'Backhaul User Plane' cloud connects to a yellow cloud labeled 'N6'. Below the clouds, there are three DC (Data Center) blocks: 'Far Edge DC', 'Edge DC', and 'Regional DC' containing a 'UPF' block. A 'Central DC' block is located at the top right, containing 'Common 3GPP control Plane components' and 'Per slice SMFs'. The 'Central DC' is connected to the 'N6' cloud and the 'UPF' block in the 'Regional DC'. + +**Figure 20: More details on the Transport Network NSSI in a D-RAN architecture. D-RAN component of transport NSSI consists two discrete networks, one for control plane interfaces and the other for user plane interfaces (source: Cisco)** + +General requirements of the TN have been identified as: + +- 1) Management and life cycle management of transport slice through automation + - a. Creation + - b. Change + - c. Deletion + +- 2) Isolation between TN slices + - a. Performance + - b. Operation + - c. Reliability + - d. Security +- 3) TN slice OAM + - a. Dynamic discovery + - b. Performance and SLA measurement +- 4) Virtualization and abstraction + - a. Use virtualization technology + - b. Isolation between slices +- 5) Multi-domain + - a. With other components of the slice + - b. Between network domains + +## Transport engineer's considerations + +With the introduction of network slicing transport network engineers need to consider: + +- 1) Concurrent connectivity between: + - a. WAN to WAN components + - b. WAN to DC based NFs + - c. DC based NFs to DC based NFs (local and remote) +- 2) L2 or L3 connectivity models +- 3) Closed user groups / VPNs +- 4) Multi-point connectivity (any to any) +- 5) Point to point connectivity +- 6) Point to multipoint. +- 7) Flexible connectivity models with the NSSI +- 8) Support consistent Quality of Service (QoS) on an end-to-end basis +- 9) Management infrastructure on transport devices and DC components to enable device level management +- 10) Management infrastructure on transport devices and DC components to enable transport slice definition and orchestration. + +# Annex C: Delay Asymmetry + +This section is not intended to describe a requirement, but rather specify a problem that is important for the design of transport networks, and yet can only be defined and solved in cooperation with other organizations such as WG4. + +Fronthaul transport networks could create a delay asymmetry between the downlink and uplink. This delay asymmetry could be caused by + +- i) difference of optical fiber lengths when uplink and downlink use separate fiber (7 m of standard single mode fiber approximatively corresponds to a 34 ns delay), +- ii) the difference of wavelength propagation times when wavelengths are not similar for uplink and downlink (typically 1.3 $\mu\text{m}$ and 1.55 $\mu\text{m}$ wavelength duplex causes a $\sim 33$ ns time difference over 20 km of standard single mode fiber ITU-T G.652), +- iii) the difference of processing time (including functions such as time multiplexing, encapsulation, compression) at transport equipment. Other transport functions could contribute to this latency asymmetry. + +We propose to have specifications (Table 27) in function of two type of RU: legacy RU (e.g. option 8 without PTP/SyncE) or O-RU (specified by WG4 based on split 7.2 and with PTP/SyncE). + +We also propose to have separate specification for cases with or without end user geolocation RAN services based on time measurement (OTDOA [observed time difference of arrival] or UTDOA [uplink time difference of arrival]). + +Another factor to be considered is the type of service and/or frequency range as listed in Table 27. + +| Latency asymmetry up & downlink fronthaul | Without geolocation based on time measurement | With geolocation based on time measurement | | | +|-------------------------------------------|--------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | | 4G | 5G FR1 | 5G FR2 | +| | | OTDOA accuracy : +/- 130.2 ns<br>OTDOA resolution : 32.5 ns<br>(higher-resolution mode based on 16.2 ns) | Not yet specified by 3GPP. This proposed value is based on replica of 4G mechanisms:<br>OTDOA accuracy: +/-32.5 ns<br>OTDOA resolution : 8.1 ns<br>Need to be updated by 3GPP Rel. 16 & 17 | Not yet specified by 3GPP. This proposed value is based on replica of 4G mechanisms:<br>OTDOA accuracy : +/-8.1 ns<br>OTDOA resolution : 2 ns<br>Need to be updated by 3GPP Rel. 16 & 17 | +| Legacy RU | DU could compensate this asymmetry for known value in the margin of +/- 10 000 ns | DU could compensate this asymmetry for known value in the margin of +/- 10 000 ns.<br><br>Latency fiber asymmetry < OTDOA resolution 32.5 ns (or 16.2 ns)<br>Proposition of values by WG9<br>- For negligible impact on geolocation time measurement < 3 ns<br>- For residual impact on geolocation time measurement < 13 ns | N/A | Not concerned | +| O-RU | O-RAN WG4 proposes absolute and relative time error margin to fiber asymmetry in annex H of WG4.CUS.0-v03.00 | Latency fiber asymmetry < O-RU TE < OTDOA resolution 32.5 ns (or 16.2 ns)<br><br>Need to be updated by O-RAN WG4 based on 3GPP TS 36.133v14.3.0 | Latency fiber asymmetry < O-RU TE < OTDOA resolution 8.1 ns<br><br>Need to be updated by O-RAN WG4 when 3GPP Rel. 16 & 17 will be available | Latency fiber asymmetry < O-RU TE < OTDOA resolution 2 ns<br><br>Need to be updated by O-RAN WG4 when 3GPP Rel. 16 & 17 will be available | + +**Table 27: Delay Asymmetry** + +# Annex ZZZ : O-RAN Adopter License Agreement + +BY DOWNLOADING, USING OR OTHERWISE ACCESSING ANY O-RAN SPECIFICATION, ADOPTER AGREES TO THE TERMS OF THIS AGREEMENT. + +This O-RAN Adopter License Agreement (the “Agreement”) is made by and between the O-RAN Alliance and the entity that downloads, uses or otherwise accesses any O-RAN Specification, including its Affiliates (the “Adopter”). + +This is a license agreement for entities who wish to adopt any O-RAN Specification. + +## Section 1: DEFINITIONS + +1.1 “Affiliate” means an entity that directly or indirectly controls, is controlled by, or is under common control with another entity, so long as such control exists. For the purpose of this Section, “Control” means beneficial ownership of fifty (50%) percent or more of the voting stock or equity in an entity. + +1.2 “Compliant Implementation” means any system, device, method or operation (whether implemented in hardware, software or combinations thereof) that fully conforms to a Final Specification. + +1.3 “Adopter(s)” means all entities, who are not Members, Contributors or Academic Contributors, including their Affiliates, who wish to download, use or otherwise access O-RAN Specifications. + +1.4 “Minor Update” means an update or revision to an O-RAN Specification published by O-RAN Alliance that does not add any significant new features or functionality and remains interoperable with the prior version of an O-RAN Specification. The term “O-RAN Specifications” includes Minor Updates. + +1.5 “Necessary Claims” means those claims of all present and future patents and patent applications, other than design patents and design registrations, throughout the world, which (i) are owned or otherwise licensable by a Member, Contributor or Academic Contributor during the term of its Member, Contributor or Academic Contributor ship; (ii) such Member, Contributor or Academic Contributor has the right to grant a license without the payment of consideration to a third party; and (iii) are necessarily infringed by a Compliant Implementation (without considering any Contributions not included in the Final Specification). A claim is necessarily infringed only when it is not possible on technical (but not commercial) grounds, taking into account normal technical practice and the state of the art generally available at the date any Final Specification was published by the O-RAN Alliance or the date the patent claim first came into existence, whichever last occurred, to make, sell, lease, otherwise dispose of, repair, use or operate a Compliant Implementation without infringing that claim. For the avoidance of doubt in exceptional cases where a Final Specification can only be implemented by technical solutions, all of which infringe patent claims, all such patent claims shall be considered Necessary Claims. + +1.6 “Defensive Suspension” means for the purposes of any license grant pursuant to Section 3, Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates, may have the discretion to include in their license a term allowing the licensor to suspend the license against a licensee who brings a patent infringement suit against the licensing Member, Contributor, Academic Contributor, Adopter, or any of their Affiliates. + +## Section 2: COPYRIGHT LICENSE + +2.1 Subject to the terms and conditions of this Agreement, O-RAN Alliance hereby grants to Adopter a nonexclusive, non-transferable, irrevocable, non-sublicensable, worldwide copyright license to obtain, use and modify O-RAN Specifications, but not to further distribute such O-RAN Specification in any modified or unmodified way, solely in furtherance of implementations of an ORAN + +Specification. + +2.2 Adopter shall not use O-RAN Specifications except as expressly set forth in this Agreement or in a separate written agreement with O-RAN Alliance. + +## Section 3: FRAND LICENSE + +3.1 Members, Contributors and Academic Contributors and their Affiliates are prepared to grant based on a separate Patent License Agreement to each Adopter under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license shall not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Adopter if that Adopter is not making a reciprocal grant to Members, Contributors and Academic Contributors, as set forth in Section 3.3. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Adopter's distributors and the use by the Adopter's customers of such licensed Compliant Implementations. + +3.2 Notwithstanding the above, if any Member, Contributor or Academic Contributor, Adopter or their Affiliates has reserved the right to charge a FRAND royalty or other fee for its license of Necessary Claims to Adopter, then Adopter is entitled to charge a FRAND royalty or other fee to such Member, Contributor or Academic Contributor, Adopter and its Affiliates for its license of Necessary Claims to its licensees. + +3.3 Adopter, on behalf of itself and its Affiliates, shall be prepared to grant based on a separate Patent License Agreement to each Members, Contributors, Academic Contributors, Adopters and their Affiliates under Fair Reasonable And Non-Discriminatory (FRAND) terms and conditions with or without compensation (royalties) a nonexclusive, non-transferable, irrevocable (but subject to Defensive Suspension), non-sublicensable, worldwide patent license under their Necessary Claims to make, have made, use, import, offer to sell, lease, sell and otherwise distribute Compliant Implementations; provided, however, that such license will not extend: (a) to any part or function of a product in which a Compliant Implementation is incorporated that is not itself part of the Compliant Implementation; or (b) to any Members, Contributors, Academic Contributors, Adopters and their Affiliates that is not making a reciprocal grant to Adopter, as set forth in Section 3.1. For the avoidance of doubt, the foregoing licensing commitment includes the distribution by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' distributors and the use by the Members', Contributors', Academic Contributors', Adopters' and their Affiliates' customers of such licensed Compliant Implementations. + +## Section 4: TERM AND TERMINATION + +4.1 This Agreement shall remain in force, unless early terminated according to this Section 4. + +4.2 O-RAN Alliance on behalf of its Members, Contributors and Academic Contributors may terminate this Agreement if Adopter materially breaches this Agreement and does not cure or is not capable of curing such breach within thirty (30) days after being given notice specifying the breach. + +4.3 Sections 1, 3, 5 - 11 of this Agreement shall survive any termination of this Agreement. Under surviving Section 3, after termination of this Agreement, Adopter will continue to grant licenses (a) to entities who become Adopters after the date of termination; and (b) for future versions of ORAN Specifications that are backwards compatible with the version that was current as of the date of termination. + +## Section 5: CONFIDENTIALITY + +Adopter will use the same care and discretion to avoid disclosure, publication, and dissemination of O-RAN Specifications to third parties, as Adopter employs with its own confidential information, but no less than reasonable care. Any disclosure by Adopter to its Affiliates, contractors and consultants should be subject to an obligation of confidentiality at least as restrictive as those contained in this Section. The foregoing obligation shall not apply to any information which is: (1) rightfully known by Adopter without any limitation on use or disclosure prior to disclosure; (2) publicly available through no fault of Adopter; (3) rightfully received without a duty of confidentiality; (4) disclosed by O-RAN Alliance or a Member, Contributor or Academic Contributor to a third party without a duty of confidentiality on such third party; (5) independently developed by Adopter; (6) disclosed pursuant to the order of a court or other authorized governmental body, or as required by law, provided that Adopter provides reasonable prior written notice to O-RAN Alliance, and cooperates with O-RAN Alliance and/or the applicable Member, Contributor or Academic Contributor to have the opportunity to oppose any such order; or (7) disclosed by Adopter with O-RAN Alliance's prior written approval. + +## Section 6: INDEMNIFICATION + +Adopter shall indemnify, defend, and hold harmless the O-RAN Alliance, its Members, Contributors or Academic Contributors, and their employees, and agents and their respective successors, heirs and assigns (the "Indemnitees"), against any liability, damage, loss, or expense (including reasonable attorneys' fees and expenses) incurred by or imposed upon any of the Indemnitees in connection with any claims, suits, investigations, actions, demands or judgments arising out of Adopter's use of the licensed O-RAN Specifications or Adopter's commercialization of products that comply with O-RAN Specifications. + +## Section 7: LIMITATIONS ON LIABILITY; NO WARRANTY + +EXCEPT FOR BREACH OF CONFIDENTIALITY, ADOPTER'S BREACH OF SECTION 3, AND ADOPTER'S INDEMNIFICATION OBLIGATIONS, IN NO EVENT SHALL ANY PARTY BE LIABLE TO ANY OTHER PARTY OR THIRD PARTY FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES RESULTING FROM ITS PERFORMANCE OR NON-PERFORMANCE UNDER THIS AGREEMENT, IN EACH CASE WHETHER UNDER CONTRACT, TORT, WARRANTY, OR OTHERWISE, AND WHETHER OR NOT SUCH PARTY HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. O-RAN SPECIFICATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES OR CONDITIONS WHATSOEVER, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE. THE O-RAN ALLIANCE AND THE MEMBERS, CONTRIBUTORS OR ACADEMIC CONTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTY OR CONDITION OF MERCHANTABILITY, SECURITY, SATISFACTORY QUALITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, ERROR-FREE OPERATION, OR ANY WARRANTY OR CONDITION FOR O-RAN SPECIFICATIONS. + +## Section 8: ASSIGNMENT + +Adopter may not assign the Agreement or any of its rights or obligations under this Agreement or make any grants or other sublicenses to this Agreement, except as expressly authorized hereunder, without having first received the prior, written consent of the O-RAN Alliance, which consent may be withheld in O-RAN Alliance's sole discretion. O-RAN Alliance may freely assign this Agreement. + +## Section 9: THIRD-PARTY BENEFICIARY RIGHTS + +Adopter acknowledges and agrees that Members, Contributors and Academic Contributors (including future Members, Contributors and Academic Contributors) are entitled to rights as a third-party beneficiary under this Agreement, including as licensees under Section 3. + +## Section 10: BINDING ON AFFILIATES + +Execution of this Agreement by Adopter in its capacity as a legal entity or association constitutes that legal entity's or association's agreement that its Affiliates are likewise bound to the obligations that are applicable to Adopter hereunder and are also entitled to the benefits of the rights of Adopter hereunder. + +## Section 11: GENERAL + +This Agreement is governed by the laws of Germany without regard to its conflict or choice of law provisions. + +This Agreement constitutes the entire agreement between the parties as to its express subject matter and expressly supersedes and replaces any prior or contemporaneous agreements between the parties, whether written or oral, relating to the subject matter of this Agreement. + +Adopter, on behalf of itself and its Affiliates, agrees to comply at all times with all applicable laws, rules and regulations with respect to its and its Affiliates' performance under this Agreement, including without limitation, export control and antitrust laws. Without limiting the generality of the foregoing, Adopter acknowledges that this Agreement prohibits any communication that would violate the antitrust laws. + +By execution hereof, no form of any partnership, joint venture or other special relationship is created between Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. Except as expressly set forth in this Agreement, no party is authorized to make any commitment on behalf of Adopter, or O-RAN Alliance or its Members, Contributors or Academic Contributors. + +In the event that any provision of this Agreement conflicts with governing law or if any provision is held to be null, void or otherwise ineffective or invalid by a court of competent jurisdiction, (i) such provisions will be deemed stricken from the contract, and (ii) the remaining terms, provisions, covenants and restrictions of this Agreement will remain in full force and effect. + +Any failure by a party or third party beneficiary to insist upon or enforce performance by another party of any of the provisions of this Agreement or to exercise any rights or remedies under this Agreement or otherwise by law shall not be construed as a waiver or relinquishment to any extent of the other parties' or third party beneficiary's right to assert or rely upon any such provision, right or remedy in that or any other instance; rather the same shall be and remain in full force and effect. \ No newline at end of file diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0114530ebfa96a80f6157ea2f5cdaac7_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0114530ebfa96a80f6157ea2f5cdaac7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6b14c6c75416de4192f48793eb5bb8f078763f77 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0114530ebfa96a80f6157ea2f5cdaac7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:69747ec96dc2a57e1e9b3b6ce11cf675f80e3bd8b7c03d02ee39ead3ba3a010c +size 88736 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/01535cceff9710f3eaac2f06712415d8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/01535cceff9710f3eaac2f06712415d8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c46749fc2938080ceca42c6e2a8ff9ad4b9e0e09 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/01535cceff9710f3eaac2f06712415d8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2a3b9cc4b92db9b0639a3af5a1e8e7b71dfd81d07f88953087863bcd591509ff +size 105519 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/022c12834266f54c4c54cdea0407fd25_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/022c12834266f54c4c54cdea0407fd25_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f97ec84d4302caa3f14c4c8f1b5a05ed70028bca --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/022c12834266f54c4c54cdea0407fd25_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b91f7fabc45c82600de38aba5582379fdcba8d83b79637c258f7f954b05cae7 +size 38079 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/03aec077aab7d519af75ce5d1f01c154_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/03aec077aab7d519af75ce5d1f01c154_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..32c5cd88af591de7511cec565ff7443983eb169e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/03aec077aab7d519af75ce5d1f01c154_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c984fe5bb5fb35bdc1f8dedaa8645c8b9fef4460246a3868a294e18ed9656c2e +size 51953 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/045f22dac1820e3e234e0171ed2c0661_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/045f22dac1820e3e234e0171ed2c0661_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ff6dd4f2cc8871039009c07d4f1431d19e0b4f45 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/045f22dac1820e3e234e0171ed2c0661_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce31c38e4ccc71d297a590418cadea2fe800de4e3091d4e1958f36bb0dd0c78f +size 17998 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0848623fc215ea184fce1fb78629e333_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0848623fc215ea184fce1fb78629e333_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8f3a62ccc8ea1a129b503ee4d19593243f9eaa80 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0848623fc215ea184fce1fb78629e333_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cdd07ee6cfd65ed5e51f278f82be10aaa8b58649c425e199430633f524a2b8f5 +size 43793 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0a7e632bc7c39487ecc6d99da4250029_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0a7e632bc7c39487ecc6d99da4250029_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8e59b312d77732d2eba550ea8da8014bfba75aa1 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0a7e632bc7c39487ecc6d99da4250029_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6180d7b70d3001d537fdeee537ab9b54f4f7cf731682cabf497362b1ca24e56a +size 72967 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0b85f4e9f9f6acd929757123f76ab5ee_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0b85f4e9f9f6acd929757123f76ab5ee_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f07fc6518de11092efbc6cf5670e89223763b24f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0b85f4e9f9f6acd929757123f76ab5ee_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1e5518d6e23a4f2f0a48d457cb132141a174304a11a683071da6e20f72d6a751 +size 17075 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0cba0a0f9c0a5f869a768b836a1969ff_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0cba0a0f9c0a5f869a768b836a1969ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..daf305f77ca03a2e502db1d778533277069f750b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0cba0a0f9c0a5f869a768b836a1969ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b3d5de228481cc01bcd99f8cd77ea797439f463b38554b60f25a5f8029eced7b +size 73417 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0d70f70f013041141064446fe38ce4d7_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0d70f70f013041141064446fe38ce4d7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4b3aa35cfcd5b93fdac24fde8f9acd9194d119b5 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0d70f70f013041141064446fe38ce4d7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:14d106f58bb47785e340743b0812d0464e9d8c7a5c18cedba17c079e9fc6da7d +size 90374 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0eb1dcffbadfe89387f807a7f5631131_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0eb1dcffbadfe89387f807a7f5631131_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..19bbfff2b255ee1a3e837793a1073cbe945bb911 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/0eb1dcffbadfe89387f807a7f5631131_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6719ddb4e4ca0a27e9f49942c4ccb1be5b8045763fdff9f1bedf7ffcdeec92c4 +size 41968 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/105490b7572a33e9d410ad2d4abe3587_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/105490b7572a33e9d410ad2d4abe3587_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a2199cce7c9b3e14843dfafa8f6d43516f1d7964 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/105490b7572a33e9d410ad2d4abe3587_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:993c0195b7fc0b19e797936f05acbe59d35b8edafc1c8e08feb5156c728702c8 +size 25704 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/12a6cda66de3e325093e73fa00e21e75_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/12a6cda66de3e325093e73fa00e21e75_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3f0e9991f3b062d252455df33563c60496c0d33 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/12a6cda66de3e325093e73fa00e21e75_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:042df10f95db681f17770d4daa80fb710f9c5ae17880ff37340a2feefa25cbaa +size 143986 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/16c4a4d12fe1b9787ef9520c16bba17c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/16c4a4d12fe1b9787ef9520c16bba17c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1243b56a7b44cf15dcf63359d3f772bafefab1b1 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/16c4a4d12fe1b9787ef9520c16bba17c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9516a283d5afccd9c38b43648c4597d80dde72208e19052ba93b36b59c067d61 +size 109526 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/177e83bf224174fd318aac2555272c4a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/177e83bf224174fd318aac2555272c4a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65ca009df837882d0372a582ddd4011770a9ec4 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/177e83bf224174fd318aac2555272c4a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6087c8f053af664dbd2b8f6e0fb4ca1ccdc93332a4f7cf67a534de25aff1cc2e +size 156016 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/20d59c6ccc13ba3ae507ae4d0e631be9_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/20d59c6ccc13ba3ae507ae4d0e631be9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0364421262988fe1ad4ab2929d1bcd115743905e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/20d59c6ccc13ba3ae507ae4d0e631be9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a3f6822c2bb3c3d45555d48b78a5815f295a202f97bd556fee66e833461bf9ff +size 22389 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/25c6e51598be4a0c8688aaaba554b365_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/25c6e51598be4a0c8688aaaba554b365_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..329819064eb3ebf173ed958011ceb67eb587cd2e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/25c6e51598be4a0c8688aaaba554b365_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f1e4992f9358931054346b574877415f6a63e477e121426f0b69a49fafc46736 +size 56005 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/29326fa245de5c0eb8447d6d679e09e0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/29326fa245de5c0eb8447d6d679e09e0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cbde72ff103893919f15e7c49e232f39dc79ff60 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/29326fa245de5c0eb8447d6d679e09e0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a3129f9574ac91320415ba7877b4b19589726427145c1971c359eb26954c18af +size 75174 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/29e052df350e2bf2356355b204ccf791_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/29e052df350e2bf2356355b204ccf791_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5cd1d9c5530cdca1c836813d9108979920bd5d5f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/29e052df350e2bf2356355b204ccf791_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8739668e2655fdab67cfb6fc839c772995c365faf569e980339cb234d4ad3ba9 +size 60807 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/2a383147760402c4ad00252b66422853_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/2a383147760402c4ad00252b66422853_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..17ddc2159b50a3687b917137df5f1a3e36e29a38 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/2a383147760402c4ad00252b66422853_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a2a75e4cdc0c4207dde27bf19b5b06e293b93876e66b6007d8ff57bb2e2257cd +size 63443 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/312a22bb17f030ec1a951ca6dff07ec5_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/312a22bb17f030ec1a951ca6dff07ec5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7d6f493eaee7bc0176f82c82d7b2f5c7e39b983b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/312a22bb17f030ec1a951ca6dff07ec5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a525d8eb856b2121d904e4b3df869686644dcff5cb61f29d757fe69d8d43e0da +size 150503 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/348010e05725652e8ff996943d81e939_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/348010e05725652e8ff996943d81e939_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8246ea1264919e4f1289e7d869e526490a04a0bc --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/348010e05725652e8ff996943d81e939_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b2b8b56215e850f115a3bd34520e7808a86bcd4bd4868fbbe76934b28caab615 +size 77846 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/35902e86858e9326c254dae18ff5e737_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/35902e86858e9326c254dae18ff5e737_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0669d76061358613e19c739ca5fd38d6f2ee0753 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/35902e86858e9326c254dae18ff5e737_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:61738ce388a3c2848fe3b76215a49df0c904f9e2ac1a43e8f97af7253709de3b +size 40964 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/37bbf56c82a87ab4d865bcbea1563f2a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/37bbf56c82a87ab4d865bcbea1563f2a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8e721ec4af244d1bddffa7e72fa2e7d917241c95 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/37bbf56c82a87ab4d865bcbea1563f2a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bd129936a9afd23aa2fc1ad11165ea2c81717125c49fe32a399144047bb132d5 +size 57559 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3a9820e6331d2cad1646c34d6f4cd5a0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3a9820e6331d2cad1646c34d6f4cd5a0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7e8749c48ffd137470cbac45c9c980436b245026 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3a9820e6331d2cad1646c34d6f4cd5a0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:658f573b7edf8aaa03e0496c5a63817bee24b950b09e73969c91844af0663f01 +size 42780 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3d31bd6a021f9c3e899c746f35d4f5d9_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3d31bd6a021f9c3e899c746f35d4f5d9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..dd1e359de650bbc4073ded607b62b5ad6eb63da6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3d31bd6a021f9c3e899c746f35d4f5d9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:135e1006ef20ae51355233eef5bcfab9adaa6f4781687f9b43b8b1b4f6e8ac87 +size 71232 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3dd5a7d4cb30c3806c56c78007ac8b33_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3dd5a7d4cb30c3806c56c78007ac8b33_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4ff54d5707bcaca1217fd0c8bba99c6653cbec73 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3dd5a7d4cb30c3806c56c78007ac8b33_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:420170f9df0079819f4d56dc3555f4b1beb05ad7edf3baa80af2672ff20fa6a6 +size 73421 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3ff6a9d95c9431ba2c2b49b6add50319_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3ff6a9d95c9431ba2c2b49b6add50319_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6739adef3a75d5ab7a4ec5ab3986c121744f6510 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/3ff6a9d95c9431ba2c2b49b6add50319_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8596c4d096508cc26723c2f46ce61f07aee3aefe70a33e8752fc9124aa32d8dc +size 37257 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/41e338caecceb0a1ebe5afe8ae6f9bfb_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/41e338caecceb0a1ebe5afe8ae6f9bfb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..540dc10f193aed3f3490a145ae48da937591d6b3 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/41e338caecceb0a1ebe5afe8ae6f9bfb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c513b608f44e25bc8852e8b58556b6a8dc039dc02a1671b2594eaf26accee70b +size 34688 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/452802d7932569eac75b018d1bb33d45_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/452802d7932569eac75b018d1bb33d45_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5436d15da835ca7e42d7355a41b9a6ec52ceeab4 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/452802d7932569eac75b018d1bb33d45_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:83e716942de0bfa438bee0f3fd0b74c839fba9cb2dcc62c7856313aa8e728f6c +size 118192 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/45558eaaaa7d40ddcecce0dd3c562fda_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/45558eaaaa7d40ddcecce0dd3c562fda_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..41af47b0800f18c77c10a26b3cc2f22b0dc760a7 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/45558eaaaa7d40ddcecce0dd3c562fda_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:773a7389d48d38bcf73a400d6e62168f7585048be72396e9d14051d249409ca4 +size 41747 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/4702df3f20e15412a752077078d91f2f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/4702df3f20e15412a752077078d91f2f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a54d33d03833e11f9b868bd42734cb70043d773f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/4702df3f20e15412a752077078d91f2f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dc9e794892375668df7d7a718cfd391c19c5853fc842e20e0cbc2bf0a59b19b8 +size 37429 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/472190837c423da2c563b433ec31c72c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/472190837c423da2c563b433ec31c72c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f1f955f55f362c9125940e2c4b4e5842a26a3477 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/472190837c423da2c563b433ec31c72c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1d507d7bf23bc34910771b2211e97027175d738d4a2fb5405ce34472a69c67b5 +size 21224 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/47cddab42f3d3d5997664ac3dbd6817a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/47cddab42f3d3d5997664ac3dbd6817a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30b2584329f3e22bcd65da2ad37cefb68b62bc2c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/47cddab42f3d3d5997664ac3dbd6817a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c8edef4d173e3ee187762c7ee11da416a6c25292910eeaf25c5c63649389c1f8 +size 50942 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/480d140fb2abe9e4c3f482132c90c979_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/480d140fb2abe9e4c3f482132c90c979_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..70089123cc7171589541207b165876e6aa79f870 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/480d140fb2abe9e4c3f482132c90c979_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a1c79686aee3066eb172a9812a13761482ca2205703cc51870158cbbef2fd2dd +size 165487 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/485fa531aebe5f5dbf1e1d002e8a50d1_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/485fa531aebe5f5dbf1e1d002e8a50d1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a341e9f3311be5bf6f1b9722755535e7821de411 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/485fa531aebe5f5dbf1e1d002e8a50d1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:96a4ad796458892ea21ecf7573c65d7f7237ab90dbd385ba9b85b6031d30175c +size 16004 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/49866a757a27c5e56a53b1180d58c283_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/49866a757a27c5e56a53b1180d58c283_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..47c4f61db3de1b1f34b3b47722b910256a63cd56 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/49866a757a27c5e56a53b1180d58c283_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e3628cfee762d0da29708bcd9983761e69accf1822dfd4d28dc7043824d597f3 +size 27436 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/49ae14c1e7b3499ba1adb2451ee37363_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/49ae14c1e7b3499ba1adb2451ee37363_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8c6f1a6939a242cfeaf0dd487e6f93af878d78cf --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/49ae14c1e7b3499ba1adb2451ee37363_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a36cd56c43eca426a62e8003a4e94a5021c4d9b2e7c98bf71ff5765d8d59f075 +size 129861 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/49ebbb0638a2848c657777708c427959_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/49ebbb0638a2848c657777708c427959_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ed3dacbc75aa946cdec5021faf3f7fb64290e00f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/49ebbb0638a2848c657777708c427959_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:880577d67aff2db9994e2ca56d7795478b97a27336893186d29c4518251be0b1 +size 103880 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/4ba5ec9b848aca9a957c057e0389a988_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/4ba5ec9b848aca9a957c057e0389a988_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e73613b752c5f8a0e9376497bbcc9ed067d2bf58 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/4ba5ec9b848aca9a957c057e0389a988_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f6df1540ad34ce83a932478b6180c640fa84dd4c02f4eea17890b9a46a1af0c8 +size 23952 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/4d67603d15f0fbab39083a7be3fd51f7_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/4d67603d15f0fbab39083a7be3fd51f7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2fdf668b2a11278d51067d606b18583ddb0e652e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/4d67603d15f0fbab39083a7be3fd51f7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2cf8801fbd0e50739a5932e5f277f06e4826f7c73d0691eeb4bc335fe256635f +size 23426 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5308ceadc08705ca528c6b605eadfa80_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5308ceadc08705ca528c6b605eadfa80_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3ecca08c73c4e3ace4fc9a38c6bced6cb58a8d93 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5308ceadc08705ca528c6b605eadfa80_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:18d8f646f4e62850ef7b0d27021818ed264c03c2714899a524817b91e49c4884 +size 37443 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5355962609510023680ac0f97c3564e2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5355962609510023680ac0f97c3564e2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f111974e4670bae96575fb1c75b4809e4262b509 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5355962609510023680ac0f97c3564e2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0399f62a7304232697137f0ad382a9619f5632e57c051ed3f1f58c4c84dc9031 +size 122263 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/540dadc39561a7e8538389d147b4eb5d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/540dadc39561a7e8538389d147b4eb5d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7728e6667124bb69d57eabb46cfaf1215ff52b34 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/540dadc39561a7e8538389d147b4eb5d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:06c9d716f84b0ec46aaa69e84c39411f410b6d008d5a65f103b896ca7f0c9171 +size 14612 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/555337ebeaa90be0ff36d77cd6d00bd6_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/555337ebeaa90be0ff36d77cd6d00bd6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..886d7e8938ce58b3bf38440541e1376c746016fd --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/555337ebeaa90be0ff36d77cd6d00bd6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5ddef069f564b89bfe5bd7e8c15912c793b10b235cafec7902b9b3b610468939 +size 38257 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/56b324032a4ed7961728ddef14f5c173_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/56b324032a4ed7961728ddef14f5c173_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e2db133b505eed940670cb740f56bb8a6310f44 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/56b324032a4ed7961728ddef14f5c173_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:86fb5529f6568c1481d8c6fa6f22a22df9d96316888bbe234ddc5cd3386c6a7f +size 167277 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/590112391ce962a773c1bf3abfff6663_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/590112391ce962a773c1bf3abfff6663_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..264c2f27582ef1ef90e01af85ec9273692690d6a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/590112391ce962a773c1bf3abfff6663_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4de1e5220e46e914a3b8d86bf954e138e402a00cfd15c5541cb7335352c57cad +size 82215 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5a156e78c5cb095d4b7bf4f1702f1bc7_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5a156e78c5cb095d4b7bf4f1702f1bc7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..77ff74564022e719e6c45afd2d298bfed4d3098b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5a156e78c5cb095d4b7bf4f1702f1bc7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:04bcf328889a2a3ac619f78981374b624c10d3afa6067a885fec00b0a6e18d98 +size 39084 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5b0a5425224aa21a1a1f67fe8e204369_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5b0a5425224aa21a1a1f67fe8e204369_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8710fe8a49da432dcdd073f512db79bf0445e35c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5b0a5425224aa21a1a1f67fe8e204369_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:97a6be3f0554bbac4c895010f6b292d80fbc039eaebd9749e3ee49942e4e690a +size 14620 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5d3afe99b49e130a2a52d6e4d9c75c8c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5d3afe99b49e130a2a52d6e4d9c75c8c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d70091b60612dc13190c97be37bb23be1c1fcc5 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5d3afe99b49e130a2a52d6e4d9c75c8c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1044a9c1a4485898c5c5e3628f45dff11509a57b0d6920e193174152168f5005 +size 61994 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5f6cfa76fc953e91cf0d4fd81de116c8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5f6cfa76fc953e91cf0d4fd81de116c8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ec36c643830f6c092101004524b6d9f82693d909 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5f6cfa76fc953e91cf0d4fd81de116c8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7dd418295e963a9fb82194400d85df94bc9f94805ea745b9e3ce28fc2700c9a5 +size 40444 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5fdae33222abf4965c0593fda91bad62_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5fdae33222abf4965c0593fda91bad62_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d16003e26881e0ba068bb180783b8dd8c95f3c74 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/5fdae33222abf4965c0593fda91bad62_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:264de7029f3c992492bbd06b789d1c6f8162eb759a5ffde43dd58b315a0ec73a +size 4504 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/6671330d212558e1cbcd34005b2b7ff6_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/6671330d212558e1cbcd34005b2b7ff6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..80036f8ec9fe2b2425bb6ee2f98870990b8b8676 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/6671330d212558e1cbcd34005b2b7ff6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f989db5106298a5c4d74dcebe747d1c31ed7d916485103fc333fe45a3e6204b5 +size 98479 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/685cd83706e5674b057f71ecee7b509d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/685cd83706e5674b057f71ecee7b509d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd70e0073820757b73b58626ea71966a09fcc35e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/685cd83706e5674b057f71ecee7b509d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f0cd4b583614e4e3d501117f8c99083e4d1ea9fb9f7c85fa633484ac78e05d14 +size 19659 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/695af1fb0ea39438d5916ba27413a596_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/695af1fb0ea39438d5916ba27413a596_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..53021b2c19fdcadc71319b3ae79b1443eef0ff0e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/695af1fb0ea39438d5916ba27413a596_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:40d4f7fa355047a2199374877f806c3b66e9285fd9a6d55ec883a9d2a33883ff +size 12917 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/6b7733e0bff69a686ba519d1af83fede_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/6b7733e0bff69a686ba519d1af83fede_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6c14698ba48d2b6259f2f3e6e2457a336b8a8ffc --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/6b7733e0bff69a686ba519d1af83fede_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5f9c00decd2f28374bd3bf70ead7e0d262f2de323ba2c7cbdda83c724f00d0d4 +size 45335 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/73cb0e3a0592c015f3b5ab1409bdb473_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/73cb0e3a0592c015f3b5ab1409bdb473_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6cb884bbae116293621126de8a28807a24a5208b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/73cb0e3a0592c015f3b5ab1409bdb473_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1314c7892316df6056259e5f86cf1c7aa19a4fa124b62d0d3fffbe400b92d02d +size 36622 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..27225d0aa300adaafdd4117dedc67749d0a1a206 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48cf233b970eeaabdd503be04bfc1c953c2305a08074046287524dfb5e1dcd7c +size 4522 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/770d0073e4a83322143a899b75821dee_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/770d0073e4a83322143a899b75821dee_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5cca5beba5759b8a0ca2f2dd52d512f422be8f66 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/770d0073e4a83322143a899b75821dee_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:85da61d5e9f847f1d4fb9f8ea09cbc375e556655517ec31d188eec11fd1bff2b +size 78614 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/7757aa533caba1806fef39a63ca3eb13_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/7757aa533caba1806fef39a63ca3eb13_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a4e51af0996e8aa2706b6030a238d7fdce05e581 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/7757aa533caba1806fef39a63ca3eb13_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7bfed740da978db1087ad5b61e8990ad52a5a21856e52f91cd25dde1264af36d +size 27502 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/818f345f65a7936a9eed4c1aaf47c145_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/818f345f65a7936a9eed4c1aaf47c145_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0256b55359b5c72b6f539ebf5fbcaaa28419c710 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/818f345f65a7936a9eed4c1aaf47c145_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1bb36fa35aff015f174cb071a0bbbe3e38e2b07b5a1027714190602935b2ecc1 +size 72001 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/84ab9508f9e978d2577ee3071c5b0b02_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/84ab9508f9e978d2577ee3071c5b0b02_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a9fe6766aab6378ef4f8840d3c9a856937a9297b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/84ab9508f9e978d2577ee3071c5b0b02_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:12395284fba2a0cd9c873f5e094cc19dc6ba67cbb19c748ca700b2446032276d +size 104572 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/865a7cb84ed56f2c1aac75ae04caff27_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/865a7cb84ed56f2c1aac75ae04caff27_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..658e5ca0a9a8f6c6991447434b705237c3ab7bdf --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/865a7cb84ed56f2c1aac75ae04caff27_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a7c096067197a8ff4b87340c4247bea7be1fbab4ee8b8842ab37fde1b9cdee29 +size 33688 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/87d8b89e56ef93c20d7d33d42df22771_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/87d8b89e56ef93c20d7d33d42df22771_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4385482b94dde27fd221a27ce2f6d4fb63cb2b9a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/87d8b89e56ef93c20d7d33d42df22771_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7fd41f3efa6fe96a126472ad47edb25fadbc8f37c5c4d890cd61f4987e50f9da +size 125335 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/8a9cd7e4f815e65db07dba06541716df_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/8a9cd7e4f815e65db07dba06541716df_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fe7201c7b77d0f80cadc039e6287808656030a39 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/8a9cd7e4f815e65db07dba06541716df_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:51c11ab05078452dec64d8dfa2a9aab43f493cab120f39d7876532886af0e667 +size 33060 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/945cc2f80e0c02d57b5c0e86ca3eb10d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/945cc2f80e0c02d57b5c0e86ca3eb10d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ca34b4ec4b420f2b4d44e3df7e5e6d8331fcba4d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/945cc2f80e0c02d57b5c0e86ca3eb10d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e69858496e0987da61f6ce37f34fbddf42651f92a648d486d82a31271a72a97a +size 27690 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/960a216f56d8e9564aaa801a4c37c641_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/960a216f56d8e9564aaa801a4c37c641_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..068e7e3c254d61f097802846f168c14f6d240d8a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/960a216f56d8e9564aaa801a4c37c641_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cd8d2b36df0e5c475bd1435e46a5a5061342aaa3a9ba21e759322cbb461ab0d4 +size 78173 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/96c44df5802b31aa092779867b4066e2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/96c44df5802b31aa092779867b4066e2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..610dd40a49e3616003671a43ec2b8e871d7af5bb --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/96c44df5802b31aa092779867b4066e2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f60d99e478b3ce2fa54fabb51c3ebac61b22a5da2147f3d727958dade6cf61cc +size 18879 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/9bc778a2ea84bc8cd5323da8ee5e92dc_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/9bc778a2ea84bc8cd5323da8ee5e92dc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c221226dfbfaf149dc021dddeca6070a6198fdce --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/9bc778a2ea84bc8cd5323da8ee5e92dc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:26dc4cd7196973244662e0a2cc086f2b0db8685c8514f275131384890d06be50 +size 74878 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/9f68c73ead642293dcd0b9c1061dce85_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/9f68c73ead642293dcd0b9c1061dce85_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9988aeb52bd2434415c815ab90cc6d0b7626f507 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/9f68c73ead642293dcd0b9c1061dce85_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6498e2941cb47cf96db9dda0c44427957a6b73fb8945932485065a5dd05b2db4 +size 36774 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a1cb8167c53cc2b9d393cd185d452a0f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a1cb8167c53cc2b9d393cd185d452a0f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..87cabd3ae946147eb323bf52eaf2098f0cc4b5fc --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a1cb8167c53cc2b9d393cd185d452a0f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0e0b170a97d032bac2e64e0cec57d84e8d3495d6d719cdcb52b29ef65955ed9c +size 19314 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a2c3f85d050237f99d6765c6defe50fd_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a2c3f85d050237f99d6765c6defe50fd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fe79dd777d3e9c4a753f96dbf84d62d14d7bc97f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a2c3f85d050237f99d6765c6defe50fd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d9312a4c6e05ea16f4acd1293fe2dfb9a97ddea9d8218c69c9963341abe59b2 +size 85884 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a710235b7a9880c7a1cdb2f39a123e64_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a710235b7a9880c7a1cdb2f39a123e64_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..94beab89ea500b9e95d886061b1ea9afb4cc7b00 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a710235b7a9880c7a1cdb2f39a123e64_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e466602288f5101eb1322360735f30b37ae89ced1a7f63df2c788712d59e82b4 +size 33909 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a768b2f714d6894cabbc427060a42aae_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a768b2f714d6894cabbc427060a42aae_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3b04eb1ccbaef12dd6a557f87faafba9b641a803 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a768b2f714d6894cabbc427060a42aae_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15e1b0f6a29f4533120ca91a1f6ab79a08a570ed50b1af1fb8b212d2ff158db0 +size 24875 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a7c910e4898c1bcfbf912a36cb8599eb_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a7c910e4898c1bcfbf912a36cb8599eb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..902c9542e31bf2b0f9066983fff8e7a8a12cd99a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/a7c910e4898c1bcfbf912a36cb8599eb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:826af5248659945b182db97d56446280e4cf8a3064156590a81f74a0da4875c7 +size 104990 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/aa77942d0b7f72f6e283cd1db22f83f5_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/aa77942d0b7f72f6e283cd1db22f83f5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d2df39bb0a4edc44f1dd1d13ba6dc280f9d999b0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/aa77942d0b7f72f6e283cd1db22f83f5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a97b3b264eb5dbbf664b1f0d2bc299ce7ffdabcbe071b79936dbb579ae6d2251 +size 73498 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ad2a50562ce5ff545595b22576dbc04f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ad2a50562ce5ff545595b22576dbc04f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..57f55c0fa2ffd72e75f30a77c19c67d621319c50 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ad2a50562ce5ff545595b22576dbc04f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:154932c4be9902b26938643ccd4be14bda186d2ddd89d3a57427c49e25fa0847 +size 73671 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b0a025008d15da6afd8f327975bb1604_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b0a025008d15da6afd8f327975bb1604_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7baf1e754b2bf6c4b60acc535bf138235f119550 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b0a025008d15da6afd8f327975bb1604_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:803a19973fca73233cf9c9d66f5ff608c8e2006c91b49c3ba9ffce5e44efb401 +size 95098 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b27f64804367618e87365286c3ee1324_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b27f64804367618e87365286c3ee1324_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5f8a01ba584a217142d14ce30507bd8499d4e6ce --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b27f64804367618e87365286c3ee1324_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7e57cb71a6cdebf25752b43346e83f0a623060cfd4baf8724146fe0f958309dc +size 64874 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b55f307eb428fbf404864e795fa1fc1b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b55f307eb428fbf404864e795fa1fc1b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6004a670fb0412044d12c293d418a814548ad12c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b55f307eb428fbf404864e795fa1fc1b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6f3b9966d88464925fb6fb60f1e5e70891cc59e014fdb5c9a71c94c6f47582d1 +size 29275 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b7b98c779dadac100ce83854aaca4bf2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b7b98c779dadac100ce83854aaca4bf2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2f9d01fed12d689f8879b5d2468149f87391d4dd --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/b7b98c779dadac100ce83854aaca4bf2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce908e1a2ebea9044ad0656e21d6678aa4cadfb66d2debcc33c6ef85d138fac6 +size 38860 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/bd4db3fa40eb4c07497b779ad4fa28e2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/bd4db3fa40eb4c07497b779ad4fa28e2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db0b613e0fac3ad2f0f255bbcbe5eca5ff9d22fb --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/bd4db3fa40eb4c07497b779ad4fa28e2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:99b85d81a5ee4501ce0cb44c1c85c35bcc0cce2cb469d1465c61e40780cea03a +size 16243 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7575c364a05dd515d7cf096c30ffc26f8ab2631 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b321cfff0a169d11fa6daa2e14ee4667e12bcfeff34e35ee9dd80b810a6385a6 +size 4491 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/bdd34ab0d8100e4ad2ea3e5c1755b3b8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/bdd34ab0d8100e4ad2ea3e5c1755b3b8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..417e4957488cb5a4c4649c981f67ad735ba96540 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/bdd34ab0d8100e4ad2ea3e5c1755b3b8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab732125a3a9bf1196dd3f4e5d70e89a2fa802896a8160918280d4bd44f427ac +size 20768 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c0a01e1839e9441dba35fbb116e3e045_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c0a01e1839e9441dba35fbb116e3e045_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..af29c7e20874298d282211b1cf817ccb5473ad94 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c0a01e1839e9441dba35fbb116e3e045_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6981c3082e70988954b7c70091880b1663d6b993c35fb22772b8c8ae75335470 +size 37165 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c21c31f0bf353e4b5e13f8c805ecc5ef_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c21c31f0bf353e4b5e13f8c805ecc5ef_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cd7dd5ecee405c283a86bd6ee7a6c25f741d7d19 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c21c31f0bf353e4b5e13f8c805ecc5ef_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9fa45ffc390a5623443af46d41ddce6e4ef3390d42fbbbd0ea709a7347d7018 +size 11351 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c378a3354e01666f4949dd2c33d39cd1_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c378a3354e01666f4949dd2c33d39cd1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fb021eb5640eafd73440732a590c4ce705604bad --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c378a3354e01666f4949dd2c33d39cd1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2854fd14adfce36b18e41599a52d7dba6f7165e3ceb9de97665f134cc188d5db +size 66000 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c5be85f763d7998937670ee966f23ab3_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c5be85f763d7998937670ee966f23ab3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7b0d7cfba2bdbbc77604ed7bf94c815df6b54864 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c5be85f763d7998937670ee966f23ab3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8a3e167e99b1ba0b84176645d6da1c1123fa5a726b0ebc76f138e827f1a3fc46 +size 46986 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c600fadfeb1d94dc7da96882441035cc_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c600fadfeb1d94dc7da96882441035cc_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a88c4b06debbf8c0b570bc3539cdf5dee673e523 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c600fadfeb1d94dc7da96882441035cc_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:98a29453e4052c1e5b536c7dd35942792ecd64eaaa61a3c5b8e2d24cf43382ba +size 61449 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c77ad995a5589a6c8a2757c4c42d1c77_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c77ad995a5589a6c8a2757c4c42d1c77_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..634e54990f459c543ec2d090c059648b6f889981 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/c77ad995a5589a6c8a2757c4c42d1c77_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0715263df51c825165856eb7103b9f0024c40f322925333c101292e7fde1a75c +size 37566 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/cc5ea48108ef18953b89d5dcc78aae5d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/cc5ea48108ef18953b89d5dcc78aae5d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..090155469ca8bc943dfb5e3682179ee96b8f2f96 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/cc5ea48108ef18953b89d5dcc78aae5d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d3d69ce76ec1e92ee855754e5808afabe7f9aa49d52a44b7c9bfa1cb9d10c782 +size 12009 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/cd32bcf38cccc256ee0681857ea26445_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/cd32bcf38cccc256ee0681857ea26445_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3031ec665237a653b1e215abb27da220300fa2d8 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/cd32bcf38cccc256ee0681857ea26445_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d7490bc46675bff3afb7a5f7288efe2024a7bb0b35db5d4b6863bef1e707feb7 +size 75629 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/cec680ac6d537a2dd657415399e9bcb2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/cec680ac6d537a2dd657415399e9bcb2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f245a7e1f91d92297893d10ce330e4cd737edacd --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/cec680ac6d537a2dd657415399e9bcb2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:911f77207d8711df483b628998b1d2d4f55c3d22e365e01b6d327464d05d5343 +size 19740 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d40bd0d0801dd51311faf382021eeded_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d40bd0d0801dd51311faf382021eeded_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c832091795254d192b48a1be1db34316b22eb986 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d40bd0d0801dd51311faf382021eeded_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:335592131cd339a9b3ada6bad37d8a7f07d36f9a365f991860759155a4a3d9a9 +size 40692 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d4c2caf85db78e3ac9b783d785e73f13_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d4c2caf85db78e3ac9b783d785e73f13_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..daab2b3459565ee8a9e81bfef87cfe791191eb35 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d4c2caf85db78e3ac9b783d785e73f13_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce66c09925b7441165393fa152ff13a9fe04160e69bdf1961eb30e52bd3002e8 +size 39988 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d7451736e3f386b5ec78a088e7ffd356_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d7451736e3f386b5ec78a088e7ffd356_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7bee3b24ade19adec42a77bd54b42b412403d760 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/d7451736e3f386b5ec78a088e7ffd356_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70d5c1105507147c89bd1289462ef6dc1a2064549bac4b04c5c8bb38b0a9df05 +size 81435 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/dcdf49fc76af6f2fadce660829b217c5_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/dcdf49fc76af6f2fadce660829b217c5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0ca11d8baa5e49a273eb013a5086bd87641bb0e7 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/dcdf49fc76af6f2fadce660829b217c5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2a5d25d45ec580ba426fccd46cb60251b6ff2e4c87f2ed4e22061ae2a2f74d2e +size 68881 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/df2822064ccdec5aba6a7a3b1417d7ee_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/df2822064ccdec5aba6a7a3b1417d7ee_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..458eee0e2d20611f410d4aedeff490916055efa5 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/df2822064ccdec5aba6a7a3b1417d7ee_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8efb271e7e3e48eb0c13c3589311acbcd3eb6ea4844ab8b033b87ec34a41d10f +size 62392 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/df6f62a8b28f5e648da3d4b09db03f5b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/df6f62a8b28f5e648da3d4b09db03f5b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..099f7e0d762bb14819182c5fd1ecef127cf3c33a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/df6f62a8b28f5e648da3d4b09db03f5b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2ab81ecefa01d7ebb6c335378536bd85ed932d5ddc8b725b8b3afd2e34d2d5e6 +size 62376 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e0883e477b6aeb3815e6ae64aa26db68_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e0883e477b6aeb3815e6ae64aa26db68_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..57a0658a5bc2d7042ca4aa20694de090958f225d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e0883e477b6aeb3815e6ae64aa26db68_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:97f37d6fb7d9a071b7dc1d8b9b49a332f25c5c60754c9305c8ea17e6d518b935 +size 39773 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e1a5cbe67a66e41b8e21a98cf27e73c5_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e1a5cbe67a66e41b8e21a98cf27e73c5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..63922cbb0a72d2876737edfecff6e5126450edbd --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e1a5cbe67a66e41b8e21a98cf27e73c5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:66e7349e49bcaff1fe862758c803fa073756b8ea9513de50d8a71f196ded28b6 +size 66493 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e1e296bb61dab365ba4c0d41eaeca55d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e1e296bb61dab365ba4c0d41eaeca55d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..29f3304a02c47e2f7efa067fdc72a29e3d98c4b1 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e1e296bb61dab365ba4c0d41eaeca55d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6b42d670b3093e8c3d3b285a18ae1cd77465d173858b3b7dc0925e1926705fe1 +size 64594 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e2840c5a15026622d7b835bd3f8030df_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e2840c5a15026622d7b835bd3f8030df_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c887108c330edafd62d98f9679b4f0f87c839a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e2840c5a15026622d7b835bd3f8030df_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:37ea49610fbd864c7e432790b925009915629eedf3704d1da2cf423e3c4e4c99 +size 129875 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e32c338d1ab875c9e451bca2a8e99e50_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e32c338d1ab875c9e451bca2a8e99e50_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c1ea9bdaefd8ea96577708e567ed5107863071bd --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e32c338d1ab875c9e451bca2a8e99e50_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0acacff5aece7462a0e62fb7acfd9fe0f3b56c64ddb1a33f548d3763b147740f +size 98561 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e3c121c6944a62c0af09157f7045bd6e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e3c121c6944a62c0af09157f7045bd6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ad179423859b3574e5e6b8696c58e0bd52ad4049 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e3c121c6944a62c0af09157f7045bd6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:aa87a2ce73902df1c4ac6b2122cbc8d49337d3610a39076a5a91bcb523acb673 +size 75789 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e7ce6d5c87461bffbb1c380e27d630f7_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e7ce6d5c87461bffbb1c380e27d630f7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1646563aece83e57b616c5b2f54bb227c510a7a9 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e7ce6d5c87461bffbb1c380e27d630f7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:08dd3f45e59f8048dbdaf91555c895f166e49410da480500fe73bcf0edbfb926 +size 18435 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e84fbdd79ea19368affbce275d267fe2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e84fbdd79ea19368affbce275d267fe2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4158f32bffb5da839c335b1d7ffb5e499fd62fe5 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/e84fbdd79ea19368affbce275d267fe2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4048b506a19639dc16f32e098d3bbe143a2cf5819e6d46adf310984189e2a287 +size 64555 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ea135a1b8992011a4de16268252a5fea_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ea135a1b8992011a4de16268252a5fea_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1fb80526815c8fdd5a746e0b2b3d575cd30535a6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ea135a1b8992011a4de16268252a5fea_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9f961657919caa65377433dfdab2528290843d9b78fd319748c1e8c6a3101146 +size 11409 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ecd140ede8c9e57f30bc695e77855af7_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ecd140ede8c9e57f30bc695e77855af7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..329d4fc98da333af63f588a17eafba7b54664a86 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ecd140ede8c9e57f30bc695e77855af7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ac99fa7514f7f687cc0fa6e9a5ffb339585d90541d9167d5eae046f237c4b5f9 +size 36741 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ed531c361515dbdc198449009c8b2d7c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ed531c361515dbdc198449009c8b2d7c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0835a6fe8b3d1724f873e0c4364b471d9536be8a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ed531c361515dbdc198449009c8b2d7c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2749273a1e979a9b63357c46170ade32e2c88b206bd7f0fc8c08fbc7f67891ae +size 4561 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/eea7084621962792e8b0aec8307b0db5_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/eea7084621962792e8b0aec8307b0db5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e3b9af377fa23bf02760d74e96aaa27c3f1e57e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/eea7084621962792e8b0aec8307b0db5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1445f80bf9b96b175b354a6a240d40d83b37bd97ea61e9b9827e3e707e0a8117 +size 69334 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f2dd516356b471fe9cce652a8ce7d94c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f2dd516356b471fe9cce652a8ce7d94c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3636c53dee11cd8f132ca66d50eea84b7a0c275e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f2dd516356b471fe9cce652a8ce7d94c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:daa641a42a7c4d96675d27ede86c411f05685c7fef04afa972e3a23dd80bfc05 +size 31243 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f33a7199e288b03df124b0d99a69e025_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f33a7199e288b03df124b0d99a69e025_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..188ad64c91443daf3d36e0ef405785cf2557dad4 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f33a7199e288b03df124b0d99a69e025_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f4fed7bb1efbee1660d6f50e43231285b47226b21bcc254b0e9b17e9dcbd9838 +size 73966 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f3427bef0e412a4ca1b581beacb95005_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f3427bef0e412a4ca1b581beacb95005_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d97cf0ffef4e7461077f8ea604345627d2d597b1 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f3427bef0e412a4ca1b581beacb95005_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0076b5c290c4758f4a55a7a97319017d31efc509d1f18ec394f8b83dda5dc037 +size 36669 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f60b6e96db1c1bc475f8f0e90c8d0bd8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f60b6e96db1c1bc475f8f0e90c8d0bd8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..480eb12d4fb3a1bc2da18103e2b63f59b7102906 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f60b6e96db1c1bc475f8f0e90c8d0bd8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ffc114922807d6d06ae0f73b43c981241844bb0bfd5efca03c715c5b7f0a0d8c +size 22328 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f7e6e95a44d456caf952fbdb5f0c1bcf_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f7e6e95a44d456caf952fbdb5f0c1bcf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b1bdda4e81b3a7e87027c956fa49a4fb5449c341 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f7e6e95a44d456caf952fbdb5f0c1bcf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:edf77e609ec81b3e9e3b03a42e4c4c53739f5b59380e669625ff78e5d42a9e00 +size 72369 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f89044650a54f3649e9067b8c3fcbd60_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f89044650a54f3649e9067b8c3fcbd60_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e841c338fc02b4474598564e1bdb9803b6846dac --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/f89044650a54f3649e9067b8c3fcbd60_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:12ff43019a33e19058c5c62d0ad2b34aa36c605218f80e1ae54d07cda6495bff +size 68560 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/fc98a77eb7f88051c6bc864eaa702fab_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/fc98a77eb7f88051c6bc864eaa702fab_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d290e85ef0e40e4fa1f7e2d67dde89e09a728cf6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/fc98a77eb7f88051c6bc864eaa702fab_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:072b05baf794ff46b4c48710758ac870673a2def5434e147b0e52fe23f8d204b +size 53030 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ff79222ec64d7dcf71ea8a4db442d335_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ff79222ec64d7dcf71ea8a4db442d335_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d82f4b51f1aa0b989ba98b5f66398e1eae2a58f0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ff79222ec64d7dcf71ea8a4db442d335_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:445148d8989bee03164f1c84143f56c1af3f59dd5094379640ba0739aed875db +size 50879 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ffddc0866e71ca35a9546ac9d27c9d01_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ffddc0866e71ca35a9546ac9d27c9d01_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7b77e93948788997550ef6aff7e039054755d7d4 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/ffddc0866e71ca35a9546ac9d27c9d01_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ed31c73624d968a93c790492d50da64225268144c383b1476e9bafc8fc0ccd97 +size 28094 diff --git a/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/raw.md b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..fb83855ae053ed17ab3290faa15cbaf10faa7c2b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00/raw.md @@ -0,0 +1,4127 @@ + + +![O-RAN ALLIANCE logo](5fdae33222abf4965c0593fda91bad62_img.jpg) + +The logo for O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN ALLIANCE' in blue and black. + +O-RAN ALLIANCE logo + +O-RAN.WG9.XTRP-SYN.0-R004-v06.00 + +Technical Specification + +# **O-RAN Open Xhaul Transport Working Group 9****Synchronization Architecture and Solution Specification** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +# 1 Revision History + +| Date | Revision | Editor | Description | +|------------|----------|-------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| 2021/03/01 | v01.00 | Kamatchi Gopalakrishnan | First revision of Timing and Synchronization Architecture and Solution document describing synchronization profiles, clock types, design consideration, time error budget calculation and network use cases. | +| 2021/11/12 | v02.00 | Kamatchi Gopalakrishnan | Second revision of this document covers additional timing solution use cases, resiliency, redundancy, and timing over PON systems. | +| 2022/07/20 | v03.00 | Kamatchi Gopalakrishnan | This revision of the document covers sync security considerations, LLS C2/C3 mixed topology models, some updates and clarifications added for some existing use cases. | +| 2023/07/06 | v4.00 | Kamatchi Gopalakrishnan | This revision of the document includes Shared O-RU uses cases for LLS-C3, Updated topology diagram and text for resiliency & failover uses cases and additional cases for security consideration and mitigation models | +| 2024/03/15 | v5.00 | Kamatchi Gopalakrishnan | This revision of the document includes End-to-end Sync monitoring framework using Telemetry streaming in Annex H. | +| 2024/11/21 | v6.00 | Kamatchi Gopalakrishnan | This revision of the document includes Yang data model for End-to-end Sync monitoring framework using Telemetry streaming in Annex H | + +## 1.1 Contributors + +Editor: Kamatchi Gopalakrishnan + +Authors in alphabetical order: + +| Author | Company | +|-------------------------|--------------------| +| Lujing Cai | AT&T | +| François Fredriex | Nokia | +| Kamatchi Gopalakrishnan | Juniper Networks | +| Aashima Raturi | Juniper Networks | +| Ramana Reddy | AltioStar Networks | +| Satheesh Kumar S | Juniper Networks | +| Sulabh Mohan Sharma | Juniper Networks | +| Krzysztof Szarkowicz | Juniper Networks | +| Karim Traore | Microchip | +| Reza Vaez-Ghaemi | Viavi Solution | +| Nader Zein | NEC | + +# 2 Contents + +| | | | | +|----|-------|------------------------------------------------------------------------------------------|----| +| 1 | 2 | Contents | | +| 2 | 1 | Revision History ..... | 2 | +| 3 | 1.1 | Contributors ..... | 3 | +| 4 | 3 | Scope ..... | 6 | +| 5 | 4 | References ..... | 7 | +| 6 | 5 | Definitions and abbreviations ..... | 9 | +| 7 | 5.1 | Definitions ..... | 9 | +| 8 | 5.2 | Abbreviations ..... | 9 | +| 9 | 6 | Network Timing and Synchronization Technology Overview ..... | 11 | +| 10 | 6.1 | Building blocks of network-based synchronization ..... | 11 | +| 11 | 6.1.1 | Synchronous Ethernet and Enhanced Synchronous Ethernet ..... | 11 | +| 12 | 6.1.2 | PRC and clocks ..... | 12 | +| 13 | 6.1.3 | PRTC and Grandmaster clocks ..... | 12 | +| 14 | 6.1.4 | APTS ..... | 15 | +| 15 | 6.1.5 | Boundary clocks, Ordinary clocks, and Transparent clocks ..... | 16 | +| 16 | 6.2 | Timing profiles ..... | 18 | +| 17 | 6.2.1 | Full Timing Support (ITU-T G.8275.1) ..... | 18 | +| 18 | 6.2.2 | Partial Timing Support (ITU-T G.8275.2) ..... | 19 | +| 19 | 6.2.3 | Assisted Partial Timing Support (ITU-T G.8275.2) ..... | 20 | +| 20 | 6.2.4 | Profile comparison table with important attributes ..... | 21 | +| 21 | 6.2.5 | Inter-working (IWF) function ..... | 22 | +| 22 | 6.2.6 | A-BTCA algorithm and PTP attributes to consider ..... | 23 | +| 23 | 6.3 | Synchronization time error budgeting model ..... | 24 | +| 24 | 6.3.1 | Factors to be considered for network synchronization budgeting ..... | 24 | +| 25 | 6.3.2 | Time Error budget calculation ..... | 29 | +| 26 | 6.3.3 | Different ORAN config models with Time Error budget ..... | 33 | +| 27 | 7 | Synchronization network models ..... | 40 | +| 28 | 7.1 | Factors to be considered for synchronization network design ..... | 40 | +| 29 | 7.1.1 | Source of clock and location of clock source ..... | 40 | +| 30 | 7.1.2 | GM/clock source resiliency ..... | 40 | +| 31 | 7.1.3 | Holdover requirements ..... | 40 | +| 32 | 7.1.4 | Usage of packet rates ..... | 41 | +| 33 | 7.1.5 | Network Topology model ..... | 42 | +| 34 | 7.1.6 | Number of hops ..... | 45 | +| 35 | 7.1.7 | Asymmetry ..... | 47 | +| 36 | 7.1.8 | PTP packet transport ..... | 49 | +| 37 | 7.1.9 | Selection of timing profile ..... | 50 | +| 38 | 7.2 | GM deployment models ..... | 51 | +| 39 | 7.2.1 | Centralized GM network model ..... | 51 | +| 40 | 7.2.2 | Distributed GM network model ..... | 52 | +| 41 | 7.2.3 | Fully distributed GM/PRTC network model ..... | 52 | +| 42 | 7.2.4 | Comparison of Centralized versus Distributed GM network model ..... | 53 | +| 43 | 8 | Timing Use cases and Solution Options ..... | 54 | +| 44 | 8.1 | Transport network topology ..... | 54 | +| 45 | 8.1.1 | C-RAN Architecture with non-collocated O-RU and O-DU ..... | 54 | +| 46 | 8.1.2 | C-RAN Architecture with O-RU and O-DU collocated at cell site ..... | 56 | +| 47 | 8.1.3 | Shared O-RU ..... | 56 | +| 48 | 8.2 | Timing Solution Options ..... | 59 | +| 49 | 8.2.1 | Timing Solutions for C-RAN Architecture with non-collocated O-RU and O-DU ..... | 59 | +| 50 | 8.2.2 | Timing Solutions for C-RAN Architecture with O-RU and O-DU collocated at cell site ..... | 67 | +| 51 | 8.2.3 | Timing Solutions for Shared O-RU ..... | 68 | +| 52 | 8.2.4 | Timing/Synchronization Redundancy & Resiliency ..... | 70 | + +| | | | +|----|------------------------------------------------------------------------------------------------|-----| +| 1 | Annex A Microwave and mmWave radio transport..... | 92 | +| 2 | A.1 Conformance to IEEE1588 and PTP profiles ..... | 92 | +| 3 | A.2 Impact of Radio channel bandwidth ..... | 92 | +| 4 | A.3 Impact of interference..... | 93 | +| 5 | A.4 Impact of dynamic capacity variations ..... | 93 | +| 6 | A.5 Impact of Band and Carrier Aggregation..... | 93 | +| 7 | A.6 Point to Multi Point (PMP) radio system..... | 93 | +| 8 | A.7 Radio Interface with asymmetry latency..... | 94 | +| 9 | A.8 Holdover Spec of BC function on the wireless transport node ..... | 94 | +| 10 | A.9 Considering of characteristics in multiple hops ..... | 94 | +| 11 | Annex B Radio operation when synchronization is lost..... | 96 | +| 12 | B.1 Potential impacts due to sync loss on O-RUs..... | 96 | +| 13 | B.1.1 TAE errors beyond the allowed range during sync loss ..... | 96 | +| 14 | B.1.2 Impact on Handover/Handoff ..... | 96 | +| 15 | B.2 Potential impacts due to sync loss on O-DU ..... | 97 | +| 16 | B.2.1 O-DU Sync loss in LLS-C3 topology ..... | 97 | +| 17 | B.2.2 O-DU Sync loss in LLS-C1/C2 topology..... | 97 | +| 18 | B.3 Best Practices ..... | 98 | +| 19 | Annex C QoS Considerations for PTP packets ..... | 99 | +| 20 | Annex D R-PHY (DOCSIS over Ethernet) ..... | 104 | +| 21 | Annex E Synchronization over TDM PON ..... | 105 | +| 22 | E.1 Short introduction to TDM PON ..... | 105 | +| 23 | E.2 Specifics with TDM PON (compared to point-point links) for frequency synchronization ..... | 107 | +| 24 | E.3 Specifics with TDM PON (compared to point-point links) for time synchronization..... | 107 | +| 25 | E.3.1 Different use cases and related requirements ..... | 107 | +| 26 | E.3.2 TDM PON capabilities ..... | 113 | +| 27 | E.3.3 Overview of TDM PON support use cases ..... | 115 | +| 28 | Annex F Multi-TDD operator considerations ..... | 116 | +| 29 | Annex G Security Considerations ..... | 117 | +| 30 | G.1 Architectural Redundancy Models..... | 117 | +| 31 | G.1.1 Network model with no sync redundancy..... | 117 | +| 32 | G.1.2 Network model with sync redundancy..... | 117 | +| 33 | G.1.3 Architecture model where O-RUs with single network interface ..... | 118 | +| 34 | G.1.4 Architecture Redundancy for PTP operation for various PTP Security Attacks..... | 119 | +| 35 | Annex H: End-to-end (e2e) Sync Monitoring using the Centralized Monitoring System ..... | 127 | +| 36 | H.1 Introduction..... | 127 | +| 37 | H.2 Various elements of e2e sync monitoring ..... | 128 | +| 38 | H.2.1 Nodes ..... | 128 | +| 39 | H.2.2 The Centralized Monitoring System (CMS) ..... | 128 | +| 40 | H.3 CMS Implementation..... | 128 | +| 41 | H.3.1 Datasets reference ..... | 129 | +| 42 | H.3.2 Static Analysis ..... | 129 | +| 43 | H.3.3 Dynamic Analysis..... | 131 | +| 44 | H.4 Telemetry Datasets ..... | 132 | +| 45 | H.4.1 High Level Datasets..... | 132 | +| 46 | H.4.2 Detailed attributes/datasets ..... | 132 | +| 47 | H.4.3 Yang Data Model reference ..... | 145 | +| 48 | H.4.4 Yang Tree ..... | 146 | +| 49 | | | + +# 3 Scope + +The document is intended to describe best practices for O-RAN Architecture and Solution for X-haul timing & synchronization. Beyond the solutions described in this document, other Architectures and Solutions may be adequate for X-haul timing & synchronization and can be considered in future versions of this document. As far as possible it tries to make no assumptions, rather define overall Open X-haul synchronization solution and architecture model, to enable the operators to understand different synchronization options and deployment models and help them to come up with right network sync model that can support the different 5G services, the different radio architectures. + +The section 6 concentrates on a general description of timing and synchronization technology, different options using different timing profiles with recommendations. The next section 7 describes the different network models, synchronization budgeting, right use of class of devices for both boundary and grandmaster clocks, solution guidelines for network operations including holdover, redundancy etc. The section 8 describes about timing solution and use cases, redundancy and resiliency network models. The annex section describes other technology aspects like, Microwave, QoS, security, PON etc. + +This document makes explicit recommendations using keyword “Reco” to insist what is officially being recommended by this specification. + +This document uses information and requirements published by O-RAN, 3GPP, IEEE, ITU-T, IETF and many other standard bodies and industry associations. + +What is not covered in this document: + +- This document shall not change the actual technology and terminologies related synchronization used on various standards - ITU-T, IEEE, IETF, 3GPP and other. + +The major changes of this revision of the document listed below: + +- The Entire spec is updated for alternative inclusive terminologies for “master” and “slave”. Used “timeTransmitter” in place of “master” and “timeReceiver” in place of “slave” as per IEEE 1588g [45] and ITU-T G.8275 [41] Appendix XII. + - In references section, these terminologies are not changed until the ITU-T specification updates the title with inclusive terminologies. +- Many use case topology figures updated for Master and Slave terminologies. +- A-BMCA is changed to A-BTCA across this specification including pictures. +- Annex H updates: + - Clear and detailed description added for each of the Static analysis requirements, including implementation details with associated datasets usage. + - Updated Table H.4-1, Table H.4-2 & Table H.4-3 with updated attributes and details. + - Table H.4-2 is modified to capture the datasets from the IEEE and ITU-T standards. Earlier version of the specification (5.0) documented with Yang Attributes. + - Added a section H.4.2.1 Datasets detailed description to describe all the new datasets defined by this sync specification for End-to-end sync monitoring framework. + - New section H.4.3 Yang Data Model reference added to capture the Yang Data model reference. + - New section H.4.4 Yang Tree added to capture entire Yang Tree is being published as part of this specification. + +# 4 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. + - For a specific reference, subsequent revisions do not apply. + - For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 15. +- [1] ITU-T G.8275.1: “Precision time protocol telecom profile for phase/time synchronization with full timing support from the network (11/2022)” + - [2] ITU-T G.8273.2: Recommendation ITU-T G.8273.2 (10/20) Timing characteristics of telecom boundary clocks and telecom time slave clocks for use with full timing support from the network + - [3] ITU-T G.8275.2: “Precision time Protocol Telecom Profile for time/phase synchronization with partial timing support from the network” + - [4] ITU-T G.8273.3: “Timing characteristics of telecom transparent clocks” + - [5] ITU-T G.8272: “Timing characteristics of primary reference time clocks” + - [6] ITU-T G.8272.1: “Timing characteristics of enhance primary reference time clocks” + - [7] ITU-T G.8271: Recommendation ITU-T G.8271 (03/20) Time and phase synchronization aspects of telecommunication networks + - [8] ITU-T G.8271.1: Recommendation ITU-T G.8271.1 (03/20) Network limits for time synchronization in packet networks with full timing support from the network + - [9] ITU-T G.8271.2: “Network limits for time synchronization in packet networks with partial timing support” + - [10] ITU-T G.8265.1: “Precision time protocol telecom profile for frequency synchronization” + - [11] ITU-T G.8265: “Architecture and requirements for packet-based frequency delivery” + - [12] ITU-T G.8264: “Distribution of timing information through packet networks” + - [13] ITU-T G.8263: “Timing characteristics of packet-based equipment clocks” + - [14] ITU-T G.8262: “Timing characteristics of a synchronous equipment slave clock” + - [15] ITU-T G.8262.1: “Timing characteristics of enhanced synchronous equipment slave clock” + - [16] ITU-T G.8261: “Timing and synchronization aspects in packet networks” + - [17] ITU-T G.8260: “Definitions and terminologies for synchronization in packet networks” + - [18] ITU-T G.8251: “The control of jitter and wander within the optical transport network (OTN)” + - [19] ITU-T G.781: “Synchronization layer functions” + - [20] IEEE 1588v2: “Precision Clock Synchronization Protocol for Networked Measurement and Control Systems + - [21] IETF RFC 8200: “Internet Protocol, Version 6 (IPv6) Specification” + - [22] IETF RFC 4443: “Internet Control Message Protocol (ICMPv6) for the Internet Protocol Version 6 (IPv6) Specification” + - [23] IEEE 802.1Q-2018: “IEEE Standard for Local and metropolitan area networks— Bridges and Bridged Networks” + - [24] IETF RFC 2474: “Definition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 Headers” + - [25] IETF RFC768: “User Datagram Protocol” + - [26] 3GPP TS 33.117 V16.2.0: “Catalogue of general security assurance requirements (Release 16)” + - [27] IEEE 802.3-2018: “IEEE Standard for Ethernet” + - [28] IETF RFC 791: “INTERNET PROTOCOL” + - [29] IEEE 802.1CMde: Time-Sensitive Networking for Fronthaul Amendment: Enhancements to Fronthaul Profiles to Synchronization, and Syntonization Standards Networking for Fronthaul, —Support New Fronthaul Interface, July 26, 2019 + - [30] IEEE 1914.1™ D3.0, Draft Fronthaul Transport Networks, November 2018. + +- 1 [31] NGMN 5G RAN CU-DU network architecture, transport options and dimensioning, version 1.0 +- 2 12 April 2019) +- 3 [32] O-RAN WG9 Technical Specifications: “X-Haul Packet switched architecture and solutions +- 4 v1.0” +- 5 [33] O-RAN, WG4, Open Fronthaul Interface, Control, User and Synchronization Plane Specification +- 6 v13.0 +- 7 [34] ITU-T G.811: Recommendation ITU-T G.811 (09/97) Timing characteristics of primary +- 8 reference clocks +- 9 [35] ITU-T G.812: Recommendation ITU-T G.812 (06/04) Timing requirements of slave clocks +- 10 suitable for use as node clocks in synchronization networks +- 11 [36] RNTF: Resilient Navigation and Timing Foundation (RNTF), “Prioritizing Dangers to the +- 12 United States from Threats to GPS: Ranking Risks and Proposed Mitigations,” 2016, White +- 13 Paper, 2, [https://rntfnd.org/wp-content/uploads/12-7-Prioritizing-Dangers-to-US-fm-Threats-to-](https://rntfnd.org/wp-content/uploads/12-7-Prioritizing-Dangers-to-US-fm-Threats-to-GPSRNTFoundation.pdf) +- 14 [GPSRNTFoundation.pdf](https://rntfnd.org/wp-content/uploads/12-7-Prioritizing-Dangers-to-US-fm-Threats-to-GPSRNTFoundation.pdf). +- 15 [37] ITU-T G.8272.1: Recommendation ITU-T G.8272.1 (11/16) Timing characteristics of enhanced +- 16 primary reference clocks +- 17 [38] ITU-T G.8271.2 Amd2: Recommendation ITU-T G.8271.2 (08/17) Amendment 2 (11/18) +- 18 Network limits for time synchronization in packet networks with partial timing support from the +- 19 network +- 20 [39] ITU-T G.8273.4: Recommendation ITU-T G.8273 (03/20) Timing characteristics of telecom +- 21 boundary clocks and telecom time slave clocks for use with partial timing support from the +- 22 network +- 23 [40] ITU-T G.671: Recommendation ITU-T G.671 (08/19) Transmission characteristics of optical +- 24 components and subsystems +- 25 [41] ITU-T G.8275: Recommendation ITU-T G.8275 (01/24) Architecture and requirements for +- 26 packet-based time and phase distribution +- 27 [42] IEEE 1588-2019: Standard for a Precision Clock Synchronization Protocol for Networked +- 28 Measurement and Control Systems +- 29 [43] ITU-T G.7721.1: Recommendation G.7721.1 (2022) Amd.1: Data model of synchronization +- 30 management +- 31 [44] Yang modules for IEEE Std 1588e-2024 +- 32 [https://github.com/YangModels/yang/blob/main/standard/ieee/published/1588/ieee1588-ptp-](https://github.com/YangModels/yang/blob/main/standard/ieee/published/1588/ieee1588-ptp-tt.yang) +- 33 [tt.yang](https://github.com/YangModels/yang/blob/main/standard/ieee/published/1588/ieee1588-ptp-tt.yang) +- 34 [45] IEEE 1588g-2022: IEEE Standard for a Precision Clock Synchronization Protocol for +- 35 Networked Measurement and Control Systems - Amendment 2: Master-Slave Optional +- 36 Alternative Terminology +- 37 + +# 5 Definitions and abbreviations + +## 5.1 Definitions + +The key words "**SHALL**", "**SHALL NOT**", "**SHOULD**", "**SHOULD NOT**", "**MAY**", and "**OPTIONAL**" in this document are to be interpreted as described in IETF RFC 2119 [25]. All key words must be in upper case, bold text. + +Items that are **REQUIRED** (contain the words **SHALL** or **SHALL NOT**) will be labelled as **[Rx]** for required. Items that are **RECOMMENDED** (contain the words **SHOULD** or **SHOULD NOT**) will be labelled as **[Dx]** for desirable. Items that are **OPTIONAL** (contain the words **MAY** or **OPTIONAL**) will be labelled as **[Ox]** for optional. + +Items, if supported, are not meant to be active at all times, but should be available for use. Their state (active or not active) should be based on configuration. + +## 5.2 Abbreviations + +Abbreviations defined in this document take precedence over the definition of 3GPP + +| | | +|--------|--------------------------------------------------------------------------------------| +| AF | Assured Forwarding | +| APTS | Assisted Partial Timing Support | +| BGP | Border Gateway Protocol | +| BTCA | Best TimeTransmitter Clock Algorithm (BTCA referred as A-BTCA in this specification) | +| BNC | Bayonet Neill–Concelman | +| CDC | Central Data Center | +| cTE | Constant Time Error | +| CU-P | Control/User Plane | +| CPRI | Common Public Radio Interface | +| C-RAN | Cloud Radio Access Network | +| dTE | Dynamic Time Error | +| DSCP | Differentiated Services Codepoint | +| DL | Downlink | +| D-RAN | Distributed Radio Access Network | +| eCPRI | enhanced Common Public Radio Interface | +| EEC | Ethernet Equipment Clock | +| eEEC | enhanced Ethernet Equipment Clock | +| EF | Expedited Forwarding | +| ePRTC | enhanced Primary Reference Time Clock | +| eSyncE | enhanced Synchronous Ethernet | +| ESMC | Ethernet Synchronization Message Channel | +| FFS | For Further Study | +| FTS | Full Timing Support | +| GC | Global Core Network | +| GNSS | Global Navigation Satellite System | +| IGP | Interior Gateway Protocol | +| IMIX | Internet Mix | +| IP | Internet Protocol | +| ITU-T | International Telecommunication Union Telecommunication Standardization Section | +| IWF | Interworking Function | +| LDP | Label Distribution Protocol | +| LAG | Link Aggregation Group | +| LTE | Long Term Evolution | + +| | | | +|----|---------|-----------------------------------------------------------| +| 1 | MAC | Media Access Control | +| 2 | MDRR | Modified Deficit Round Robin | +| 3 | M-P | Management Plane | +| 4 | nsec | Nano seconds | +| 5 | OAM | Operation, Administration and Maintenance | +| 6 | O-CU | O-RAN Central Unit | +| 7 | OCXO | Oven Controlled Crystal Oscillator | +| 8 | ODN | Optical Distribution Network | +| 9 | O-DU | O-RAN Distributed Unit | +| 10 | OLT | Optical Line Termination | +| 11 | ONU | Optical Network Unit | +| 12 | O-RAN | Open Radio Access Network | +| 13 | OTN | Optical Transport Networking | +| 14 | PDV | Packet Delay Variation | +| 15 | PHB | Per-hop behaviour | +| 16 | PIR | Peak Information Rate | +| 17 | PON | Passive Optical Network | +| 18 | PRTC | Primary Reference Time Clock | +| 19 | PTP | Precision Time Protocol | +| 20 | PTPoE | Precision Time Protocol over Ethernet | +| 21 | PTPoIP | Precision Time Protocol over Internet Protocol | +| 22 | PTS | Partial Timing Support | +| 23 | QoS | Quality of Service | +| 24 | RoE | Radio over Ethernet | +| 25 | RSVP | Resource Reservation Protocol | +| 26 | SFN | Sub Frame Number | +| 27 | S-P | Synchronization Plane | +| 28 | SyncE | Synchronous Ethernet | +| 29 | TAE | Time Alignment Error | +| 30 | TBD | To Be Defined | +| 31 | TDMA | Time Division Multiple Access | +| 32 | TPS-TC | Transmission Protocol Specific – Transmission Convergence | +| 33 | TS | Time-Stamp | +| 34 | TTI | Transmission Time Interval | +| 35 | T-BC | Telecom Boundary Clock | +| 36 | T-BC-P | Partial Telecom Boundary Clock | +| 37 | T-BC-A | Assisted Telecom Boundary Clock | +| 38 | T-GM | Telecom Grand Master | +| 39 | T-TC | Telecom Transparent Clock | +| 40 | T-TSC | Telecom Time Synchronous Clock | +| 41 | T-TSC-A | Assisted Telecom Time Synchronous Clock | +| 42 | T-TSC-P | Partial Telecom Time Synchronous Clock | +| 43 | UDP | User Datagram Protocol | +| 44 | UL | Up link | +| 45 | UTC | Coordinated Universal Time | +| 46 | VLAN | Virtual Local Area Network | +| 47 | WDRR | Weighted Deficit Round Robin | +| 48 | WFQ | Weighted Fair Queueing | +| 49 | WRR | Weighted Round Robin | + +# 6 Network Timing and Synchronization Technology Overview + +## 6.1 Building blocks of network-based synchronization + +This section covers different building blocks required for network-based synchronization. This includes different physical layer and packet layer clocks. + +### 6.1.1 Synchronous Ethernet and Enhanced Synchronous Ethernet + +#### 6.1.1.1 Synchronous Ethernet Clock + +Synchronous Ethernet Clock is also referred as Ethernet Equipment Clock (EEC). The ITU-T standard G.8262 [14] specification defines both synchronous Ethernet Equipment Clock (EEC) and OTN Equipment Clock (OEC). + +There are two options available for Synchronous Equipment Clocks. The first option, referred to as “Option 1”, applies to synchronous equipment designed to interwork with networks optimized for the 2048 kbits/s hierarchy. The second option, referred to as “Option 2”, applies to synchronous equipment designed to interwork with networks optimized for the 1544 kbits/s hierarchy. + +An EEC recovers the clock at physical layer level. The performance and recovery of clock at physical layer is independent of packet layer. Synchronous is hop by hop clock recovery and drive model. Any one node in the chain is not capable to support SyncE, it is considered to be the clock chain is broken. + +Sync-E chain: + +![Diagram of a Sync-E chain showing a sequence of nodes: PRC, EEC, EEC, EEC, and O-RU/EEC, connected by arrows indicating the flow of the clock signal.](c21c31f0bf353e4b5e13f8c805ecc5ef_img.jpg) + +``` + +graph LR + PRC[PRC] --> EEC1[EEC] + EEC1 --> EEC2[EEC] + EEC2 --> EEC3[EEC] + EEC3 --> O_RU_EEC[O-RU/EEC] + +``` + +Diagram of a Sync-E chain showing a sequence of nodes: PRC, EEC, EEC, EEC, and O-RU/EEC, connected by arrows indicating the flow of the clock signal. + +**Figure 6.1.1-1 : Sync-E chain** + +In Figure 6.1.1-1, every node is capable of supporting Synchronous Ethernet between PRC to O-RU. This is a good example of synchronous Ethernet network chain deployment model. + +Broken Sync-E chain: + +![Diagram of a Broken Sync-E chain showing a sequence of nodes: PRC, EEC, No EEC, EEC, and O-RU/EEC, connected by arrows. The 'No EEC' node is highlighted in yellow, indicating it is not capable of supporting SyncE.](cc5ea48108ef18953b89d5dcc78aae5d_img.jpg) + +``` + +graph LR + PRC[PRC] --> EEC1[EEC] + EEC1 --> No_EEC[No EEC] + No_EEC --> EEC2[EEC] + EEC2 --> O_RU_EEC[O-RU/EEC] + +``` + +Diagram of a Broken Sync-E chain showing a sequence of nodes: PRC, EEC, No EEC, EEC, and O-RU/EEC, connected by arrows. The 'No EEC' node is highlighted in yellow, indicating it is not capable of supporting SyncE. + +**Figure 6.1.1-2: Broken Sync-E chain** + +In Figure 6.1.1-2, the node after first EEC node does not support EEC. In this case SyncE clock chain is broken at the “No EEC” capable box, though the next node is capable of SyncE. + +Both for Option-1 and Option-2 compliant EEC clocks, under free-running conditions, the output frequency accuracy of the different types of node clocks should not exceed 4.6 ppm with regard to a reference traceable to a primary reference clock over a time period of T of one year. + +The maximum phase transient at the output due to reference switching for option-1 EEC clock is 1000 nano seconds of phase error. + +In the chain of EEC network, the clock quality is advertised by one node to another node using ESMC messages. Based on the option type, there are different clock qualities defined based on the stratum level of the clocks in G.8264 [12] standard. Any given node selects a best clock source based on the Quality Level (clock-quality) advertised in the ESMC message using clock selection algorithm. + +**Reco: This ORAN specification focuses only EEC. Usage of OEC is for future.** + +#### 6.1.1.2 Enhanced Synchronous Ethernet Clock eEEEC + +The ITU-T standard G.8262.1 [15] defines two types of enhanced synchronous equipment clocks. One is enhanced synchronous ethernet equipment clock (eEEEC) and the enhanced synchronous OTN equipment clock (eOEC). + +**Reco: This ORAN specification focuses only eEEEC. Usage of eOEC is for future.** + +One of main performance attribute of eEEEC that differs from EEC is the permissible short term phase transient error during reference switching. In case of EEC 50 ns/s drift is accepted, whereas in eEEEC clocks only 10 ns/s is allowed. + +eEEEC support is required for any boundary clock that claims Class-C compliance. + +There are additional TLVs defined to advertise the eEEEC clocks as part of ITU-T G.8264 [12] standard + +QL-PRTC, QL-ePRTC, QL-eEEEC and QL-ePRC etc. + +Note: Refer ITU-T G.8264 [12] standard for detailed information. + +### 6.1.2 PRC and clocks + +The main function of a Primary Reference Clock (PRC), as specified in ITU-T G.811, is to provide the reference signal for the timing or synchronization of other clocks within a network or section of a network, including the clock specified in Recommendation ITU-T G.812 within the network nodes where the PRC is located. The long-term accuracy of the PRC is in the order of 1 part in $10^{11}$ or better with verification to Coordinated Universal Time (UTC). PRCs are typically built using Caesium clocks. PRCs are at the top level of the clock hierarchy with one of the highest accuracies [34][35]. + +### 6.1.3 PRTC and Grandmaster clocks + +The main function of a PRTC, as defined in ITU-T G8272.1 amd1, is to deliver a primary time reference to be used in time and/or phase synchronization by other clocks of the network. + +The PRTC takes its reference signal from a system connected to a recognized primary time standard (e.g., a global navigation satellite system or from a national laboratory participating in time standards generation). It can also optionally take a frequency input reference traceable to a PRC to maintain the local representation of the timescale during outages of the input time reference (i.e., extend the phase/time holdover period of the clock). + +The performance of a GNSS-based PRTC can be impacted by several errors and one of the major sources of error is the ionospheric delay. The ionosphere introduces a variable time delay in the propagation of signals from the satellite to the receiver. The use of multi-constellation GNSS receivers is key to mitigate ionosphere + +effects and improve time accuracy. There are currently 6 GNSS satellite constellations in orbit providing geolocation and time distribution (GPS, GLONASS, BeiDou, Galileo, Indian Regional Navigation Satellite System-IRNSS, Quasi-Zenith Satellite System-QZSS). A multi-constellation GNSS increases the number of satellites in the view, which help mitigate issues linked to obstructions (e.g., foliage, buildings, etc) and provide additional redundancy and robustness of the system. + +The low GNSS signal power on Earth makes it very susceptible to interference from weather and other signals. Over the past years, an increasing number of GNSS jamming, and spoofing have been reported. A small jammer can disrupt a GNSS receiver for several kilometres. GNSS jamming is a relatively simple technique that consists of producing an RF signal strong enough to interfere with the GNSS signal. GNSS jamming is a continuing threat and GNSS jamming devices have proliferated on the Internet. + +GNSS spoofing is another threat more insidious and harder to detect. It consists of sending a false signal with a false position fix, a false clock offset, or both that the receiver interprets as the authentic GNSS signal. + +The U.S. Department of Homeland Security has declared the GPS “a single point of failure for critical infrastructure.” [36] + +The performance of the PRTC is characterized by two noise generation aspects: + +- the constant time error (time offset) at its output compared to the applicable primary time standard (e.g., UTC). +- the amount of phase error (wander and jitter) produced at its output. The phase error is measured using the calculation of the maximum time interval error (MTIE) and the time deviation (TDEV) performance metrics. + +ITU-T G.8272-2018 [5] specifies that under normal, locked operating conditions, the time output of the PRTC-A, or the combined PRTC-A and T-GM function, should be accurate to within 100 ns or better when verified against the applicable primary time standard (e.g., UTC). + +ITU-T G.8272-2018 [5] specifies that under normal, locked operating conditions, the time output of the PRTC-B, or the combined PRTC-B and T-GM function, should be accurate to within 40 ns or better when verified against the applicable primary time standard (e.g., UTC). + +There are two types of PRTCs, PRTC-A and PRTC-B, characterized by different performance specifications. Note that the PRTC function can be combined with a Telecom Grand Master (T-GM) function in a single piece of equipment (PRTC+T-GM). + +It is becoming increasingly critical to protect the GNSS signal of the PRTC with an anti-jamming and anti-spoofing system. This system should not only detect and isolate the GNSS jamming and spoofing incident but also extend its holdover for several days in case a complete loss reception. + +![Block diagram showing the anti-jamming/spoofing function. A GNSS signal (represented by a triangle) enters an 'Anti jamming/spoofing' block. The output of this block is connected to a larger block labeled 'PRTC+T-GM'.](ea135a1b8992011a4de16268252a5fea_img.jpg) + +``` + +graph TD + GNSS[GNSS] --> AntiJamming[Anti jamming/spoofing] + AntiJamming --> PRTC_TGM[PRTC+T-GM] + +``` + +Block diagram showing the anti-jamming/spoofing function. A GNSS signal (represented by a triangle) enters an 'Anti jamming/spoofing' block. The output of this block is connected to a larger block labeled 'PRTC+T-GM'. + +**Figure 6.1.3-1: Anti-jamming/spoofing function** + +The PRTC+T-GM typically implements three logical output interfaces to provide: + +- Frequency (e.g., 2 048 kHz interfaces, 1 544 kbit/s interfaces, 2 048 kbit/s interfaces, Synchronous Ethernet interfaces, 1PPS single ended BNC - 50 $\Omega$ phase-synchronization measurement interface, 10 MHz interfaces, etc). +- Phase and time (e.g., Ethernet interface carrying PTP messages, etc). + +![Figure 6.1.3-2: PRTC functional model diagram. A central box labeled 'PRTC+T-GM' receives inputs from a 'GNSS' antenna and an 'External frequency input ref. (optional)'. It outputs three signals: 'Time reference (e.g., 1PPS)', 'Phase reference (e.g., PTP)', and 'Frequency reference (e.g., 2 048 KHz)'.](a1cb8167c53cc2b9d393cd185d452a0f_img.jpg) + +Figure 6.1.3-2: PRTC functional model diagram. A central box labeled 'PRTC+T-GM' receives inputs from a 'GNSS' antenna and an 'External frequency input ref. (optional)'. It outputs three signals: 'Time reference (e.g., 1PPS)', 'Phase reference (e.g., PTP)', and 'Frequency reference (e.g., 2 048 KHz)'. + +**Figure 6.1.3-2: PRTC functional model** + +When a PRTC+T-GM loses its input phase and time references, it enters the phase/time holdover state where it relies on the holdover of a local oscillator, or on an optional external input frequency reference traceable to a primary reference clock (PRC), or both. The quality of the local oscillator is an important feature. An OCXO oscillator can for example drift 400 ns in 8 hours while it takes a 1.8 day for a Rubidium oscillator to drift 400 ns. Note that the NR-TDD time error requirement with respect to a common reference is 1.5 $\mu$ s. Rubidium oscillator provides a 3-30x improvement over best aging XO spec (0.01ppd/day). Rubidium oscillators are typically deployed to in PRTC+T-GM locations where there is a need to offer an additional level of protection with a better holdover period when no other mechanism is available. + +The table below shows the performance of the main types of clock technologies. + +| Technology | Intrinsic Accuracy | Stability (1s) | Stability (floor) | Aging (/day) initial to ultimate | +|----------------|------------------------|-----------------|-------------------|----------------------------------| +| Hydrogen Maser | $\sim 10^{-11}$ | $\sim 10^{-13}$ | $\sim 10^{-15}$ | $10^{-15}$ to $10^{-16}$ | +| Cesium Beam | $\sim 10^{-13}$ | $\sim 10^{-11}$ | $\sim 10^{-14}$ | nil | +| Rb Vapor Cell | $\sim 10^{-9}$ | $\sim 10^{-11}$ | $\sim 10^{-13}$ | $10^{-11}$ to $10^{-13}$ | +| Hi-quality Qz | $10^{-6}$ to $10^{-8}$ | $\sim 10^{-12}$ | $\sim 10^{-12}$ | $10^{-9}$ to $10^{-11}$ | + +**Table 6-1: Clock technologies table** + +Another difference between Rubidium and OCXO oscillators that when they are locked to a GNSS reference, Rubidium oscillators have better ability to filter the noise of the GNSS reference. + +**Note that, as specified in ITU-T 8272-2018, the phase/time holdover requirements applicable to a PRTC are for further study.** + +enhanced PRTC (ePRTC) is new class of clock, defined in ITU-T G.8272.1 [6], with the purpose of providing more stringent output performance requirements and a frequency input directly from an autonomous primary reference clock. + +![Figure 6.1.3-3: ePRTC functional model. A block diagram showing an ePRTC block. On the left, an antenna icon is connected to the block. Below it, text reads 'External frequency input ref. (autonomous primary reference clock: e.g. Cesium)'. On the right, three arrows point out from the block: 'Time reference (e.g., 1PPS)', 'Phase reference (e.g., PTP)', and 'Frequency reference (e.g., 2 048 KHz)'.](045f22dac1820e3e234e0171ed2c0661_img.jpg) + +Figure 6.1.3-3: ePRTC functional model. A block diagram showing an ePRTC block. On the left, an antenna icon is connected to the block. Below it, text reads 'External frequency input ref. (autonomous primary reference clock: e.g. Cesium)'. On the right, three arrows point out from the block: 'Time reference (e.g., 1PPS)', 'Phase reference (e.g., PTP)', and 'Frequency reference (e.g., 2 048 KHz)'. + +**Figure 6.1.3-3: ePRTC functional model** + +ITU-T G.8272.1 [37] specifies that under normal, locked operating conditions, the time output of the ePRTC- or the combined ePRTC and T-GM function, should be accurate to within 30 ns or better when verified against the applicable primary time standard (e.g., UTC). + +When an ePRTC loses all its input phase and time references and enters the phase/time holdover state, it relies on an autonomous primary reference clock (PRC) frequency reference input. An ePRTC can also rely on several input frequency references used to ensemble a very stable frequency reference. An ePRTC is an autonomous source of time and independent timescale that is implemented with one or two co-located atomic clocks. + +The holdover requirements of an ePRTC-A when verified against the applicable primary time standard (e.g., UTC) is defined from the start of phase/time holdover, after 30 days of continuous normal operation, to within a value increasing linearly from 30 ns to 100 ns over a 14-day period (see Table and Figure below). ePRTCs are typically deployed in major timing centres in order to provide a long holdover capability. ePRTCs are extremely reliable clock immune to jamming and spoofing given their high level of autonomy. + +The holdover requirements of the ePRTC-B, a higher-performance ePRTC, are for further study. + +### 6.1.4 APTS + +Assisted partial timing support (APTS) offers a backup timing source to GNSS-based inter-working function (IWF P-F) [38]. + +The latter serves as the primary synchronization source for the full timing support network in the access network. APTS typically uses a secondary synchronization source from the partial timing support network in the pre-aggregation/aggregation network as a backup mechanism provided that the full timing support time error budget remains in relatively small (e.g., two or three hops). + +In normal mode of operation, the time of the GNSS-based IWF time is sourced from GNSS, and in the event of GNSS loss, it relies on the frequency derived from the incoming PTP flow of the partial timing support network to provide or hold time. Note that alternatively, it is possible to use a traceable frequency input (e.g., SyncE, 2 048 kHz interfaces, 1 544 kbit/s interfaces, 2 048 kbit/s interfaces, etc) from a local frequency source. + +ITU-T G.8273.4 [39] specifies the timing characteristics of telecom boundary clocks and telecom time synchronous clocks for time and phase synchronization equipment used in synchronization networks that operates in the assisted partial timing support (APTS). + +![Diagram illustrating the assisted partial timing support (APTS) architecture. It shows two 'Packet network' ovals. The first oval is connected to a 'PRTC/GM' block, which is connected to a 'GNSS' antenna. Below this section is a bracket labeled 'Partial timing support'. The second oval is connected to an 'IWF (GNSS based PRTC)' block, which is connected to a 'GNSS' antenna with a red 'X' over it, indicating loss of GNSS. Below this section is a bracket labeled 'Full timing support'. The second 'Packet network' oval is connected to three 'RU' (Radio Units) blocks.](20d59c6ccc13ba3ae507ae4d0e631be9_img.jpg) + +Diagram illustrating the assisted partial timing support (APTS) architecture. It shows two 'Packet network' ovals. The first oval is connected to a 'PRTC/GM' block, which is connected to a 'GNSS' antenna. Below this section is a bracket labeled 'Partial timing support'. The second oval is connected to an 'IWF (GNSS based PRTC)' block, which is connected to a 'GNSS' antenna with a red 'X' over it, indicating loss of GNSS. Below this section is a bracket labeled 'Full timing support'. The second 'Packet network' oval is connected to three 'RU' (Radio Units) blocks. + +### 6.1.5 Boundary clocks, Ordinary clocks, and Transparent clocks + +As per IEEE-1588v2 [20] standard the definition of boundary clock and ordinary clocks: + +#### Boundary clock: + +A clock that has multiple Precision Time Protocol (PTP) ports in a domain and maintains the timescale used in the domain. It may serve as the source of time, i.e., be a timeTransmitter clock, and may synchronize to another clock, i.e., be a timeReceiver clock. + +#### Ordinary clock: + +A clock that has a single Precision Time Protocol port in a domain and maintains the timescale used in the domain. It may serve as a source of time, i.e., be a timeTransmitter clock, or may synchronize to another clock, i.e., be a timeReceiver clock. + +#### Transparent clock: + +A device that measures the time taken for a Precision Time Protocol (PTP) event message to transfer the device and provides this information to clocks receiving this PTP event message. + +The ITU-T standard defined additional sub-type of boundary, ordinary and transparent clocks with some loaded functions, typically called Telecom Boundary clocks, Telecom Grandmaster clock and Telecom Time Synchronous clock and Telecom Transparent Clock + +| Clock type/name | Clock specification | Description | +|-----------------|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| T-BC | G.8273.2 [2] | Telecom Boundary Clock (T-BC) recovers time and phase using PTP packet exchange and frequency using physical layer clock (Sync-E) and delivers both time/phase and frequency to downstream to nodes. Used in full timing support network as per G.8275.1 [1] profile. | +| T-TSC | G.8273.2 [2] | Telecom Time Synchronous Clock (T-TSC) recovers Time and Phase using PTP packet exchange and frequency using physical layer clock (ex: Sync-E). Used in full timing support network as per G.8275.1 [1] profile. | +| T-BC-P | G.8273.4 [39] | Partial support Telecom Boundary Clock (T-BC-P) recovers time and phase using PTP packet exchange and usage of physical layer clock for frequency recovery is optional. Used in partial timing support network as per G.8275.2 [3] profile. | +| T-BC-A | G.8273.4 [39] | Assisted Partial support Telecom Boundary Clock (T-BC-A) recovers time/phase from GNSS (PRTC) as the primary source and network based PTP as backup. | +| T-TSC-P | G.8273.4 [39] | Partial support Telecom Time Synchronous Clock (T-TSC-P) recovers time/phase using PTP packet exchange and usage of physical layer clock is optional. Used in partial timing support network as per G.8275.2 [3] profile. | +| T-TSC-A | G.8273.4 [39] | Assisted partial support Telecom Time Synchronous Clock (T-TSC-A) recovers time/phase from GNSS (PRTC) as the primary source and network based PTP as backup. | +| T-TC | G.8273.3 [4] | Telecom Transparent Clock (T-TC) operates in syntonized mode using physical layer clock (ex: Sync-E) apart from measuring the time taken for a Precision Time Protocol (PTP) event message to transit the device. | + +1 **Reco:** This specification recommends T-BC and T-TSC clocks in general for X-haul networks including +2 **Fronthaul network. Also recommends using T-BC over T-TC wherever possible. Usage of other clocks** +3 **like T-BC-A/P, T-TSC-A/P are optional.** + +## 6.2 Timing profiles + +Timing profile specifies the IEEE 1588 functions that are necessary to ensure network element interoperability for the delivery of accurate phase/time synchronization. + +### 6.2.1 Full Timing Support (ITU-T G.8275.1) + +ITU-T G.8275.1 [1] specifies a profile for telecommunication applications based on IEEE 1588 precision time protocol (PTP). The profile specifies the IEEE 1588 functions that are necessary to ensure network element interoperability for the delivery of accurate phase/time synchronization. The profile is based on the full timing support from the network architecture as described in ITU-T G.8275 [41] and definitions described in ITU-T G.8260 [17]. + +This version of the profile specifies the high-level design requirements, modes of operation for the exchange of PTP messages, the PTP protocol mapping, the best timeTransmitter clock algorithm (BTCA) options, as well as the PTP protocol configuration parameters. + +Note-1 – The parameters defined in this version of the specification are chosen based on the case where physical layer frequency support is provided, and the case without physical layer frequency support (i.e., PTP only) is for further study + +**Reco – This specification restricts the usage of IEEE1588 version 2.0 [20] only. It does not include the IEEE1588 version 2.1, and this version will be considered in the future.** + +As per this profile every network node between Grand Master device and end-application is PTP and Sync-E aware devices. It is referred as Full path Timing Support (FTS) profile. + +The common accepted devices are Telecom Boundary Clock (T-BC) and Telecom Transparent Clock (T-TC) for the nodes between GM and End-application. + +![Figure 6.2.1-1: Full Timing Support network model. The diagram shows a sequence of network elements connected by arrows. It starts with a black box labeled 'T-GM'. This is followed by three black boxes, each labeled 'T-BC/ T-TC'. The final element is a black box labeled 'O-RU/ T-TSC', which is connected to a blue antenna icon.](485fa531aebe5f5dbf1e1d002e8a50d1_img.jpg) + +``` + +graph LR + TGM[T-GM] --> TBC1[T-BC/ T-TC] + TBC1 --> TBC2[T-BC/ T-TC] + TBC2 --> TBC3[T-BC/ T-TC] + TBC3 --> ORU[O-RU/ T-TSC] + ORU --- Antenna[Antenna] + +``` + +Figure 6.2.1-1: Full Timing Support network model. The diagram shows a sequence of network elements connected by arrows. It starts with a black box labeled 'T-GM'. This is followed by three black boxes, each labeled 'T-BC/ T-TC'. The final element is a black box labeled 'O-RU/ T-TSC', which is connected to a blue antenna icon. + +Figure 6.2.1-1: Full Timing Support network model + +**Reco: This ORAN specification recommends T-BC for this profile deployment. Usage of T-TC is optional.** + +### 6.2.2 Partial Timing Support (ITU-T G.8275.2) + +This profile is for telecommunication applications based on [IEEE 1588] precision time protocol (PTP). The profile specifies the IEEE 1588 functions that are necessary to ensure network element interoperability for the delivery of accurate phase/time (and frequency) synchronization with partial timing support from network and commonly referred as PTS profile. + +This profile defines the PTP profile for unicast mode only. + +![Figure 6.2.2-1: Partial Timing Support network model. The diagram shows a sequence of network elements: T-GM (black box) connected to a PTP unaware network (orange cloud), which connects to T-BC-P (black box). T-BC-P connects to another PTP unaware network (orange cloud), which connects to T-BC (IWF) (black box). Finally, T-BC (IWF) connects to O-RU/T-TSC (black box). Arrows indicate the direction of communication from left to right.](472190837c423da2c563b433ec31c72c_img.jpg) + +``` + +graph LR + TGM[T-GM] --> N1((PTP unaware)) + N1 --> TBCP[T-BC-P] + TBCP --> N2((PTP unaware)) + N2 --> TBCIWF[T-BC (IWF)] + TBCIWF --> ORU_TTSC[O-RU/T-TSC] + +``` + +Figure 6.2.2-1: Partial Timing Support network model. The diagram shows a sequence of network elements: T-GM (black box) connected to a PTP unaware network (orange cloud), which connects to T-BC-P (black box). T-BC-P connects to another PTP unaware network (orange cloud), which connects to T-BC (IWF) (black box). Finally, T-BC (IWF) connects to O-RU/T-TSC (black box). Arrows indicate the direction of communication from left to right. + +**Figure 6.2.2-1: Partial Timing Support network model** + +The clock specifications for T-BC-P and T-TSC-P are defined in ITU-T G.8273.4 [39] standard. In a Partial Timing Support (PTS) model, some or all nodes between the Grandmaster and End time-synchronous clock (T-TSC) are not aware of PTP. As in Figure 6.2.2-1 above, the T-GM and T-BC-P is connected over a network (that may contain one or multiple network nodes) that do not support PTP. + +The term telecom boundary clock for partial timing support (T-BC-P) refers to a device consisting of a boundary clock (BC) as defined in [IEEE 1588], with additional performance characteristics as defined in ITU-T G.8273.4 [39]. + +The term telecom time synchronous clock for partial timing support (T-TSC-P) refers to a device consisting of either an ordinary clock (OC), with one PTP port, or a boundary clock (BC), with multiple PTP ports, as defined in [IEEE 1588] and with additional performance characteristics as defined in ITU-T G.8273.4 [39]. + +The IWF stands for Inter Working Function. In this network model the IWF boundary clock exercises G.8275.2 [3] (Partial timing support) profile towards the network Grand Master side and G.8275.1 [1] (Full timing support) profile towards the O-RU/T-TSC. + +The network operating in partial timing support may not be sufficient to meet all of the applicable timing requirements. See Appendix II in G.8271.2 [9] on *Considerations for handling precision time protocol traffic in networks with partial timing support*. One important aspect is that this methodology requires manual compensation for asymmetries at installation and at any change in the network. This is particularly critical when the transport technology can introduce variable asymmetries (e.g., at restart of an equipment). + +The use of G.8275.2 [3] in partial timing support is for further study in the CUS [33] specification, in particular, the following is stated in the CUS specification (ref.12): “Transport of PTP directly over L2 Ethernet (ITU-T G.8275.1 [1] full timing on-path support) is assumed in this version of the specification, whilst transport of PTP over UDP/IP (ITU-T G.8275.2 [3] partial timing support from the network) is also possible albeit with unassured synchronization performance.” + +It should be noted that if the cluster of base stations is synchronized via a full timing support segment (i.e., after the IWF), the impact from the partial timing support segment of the network on timing requirements related to coordination features such as carrier aggregation, is negligible. + +**Reco: ITU-T G.8275.2 [3] standard allows both PTPoIPv4 and PTPoIPv6 unicast transport mechanisms, this ORAN specification recommends using PTPoIPv4. Usage of PTPoIPv6 is FFS.** + +**Reco:** This O-RAN specification does not recommend deployment as shown in figure 6.2.2 to synchronize O-RUs not connected to same IWFs. + +### 6.2.3 Assisted Partial Timing Support (ITU-T G.8275.2) + +In APTS model, PTP is used as a backup timing source to a local time reference (e.g., primary reference time clock (PRTC) based on the global navigation satellite system (GNSS)). It is not intended to use PTP as the primary timing source. + +Similar considerations as indicated above may apply for the periods during which the GNSS is lost and PTP becomes the synchronization timeTransmitter for the O-RU. However, differently from the previous case, APTS allows for automatic removal of static asymmetries when PTP is used. + +![Figure 6.2.3-1: APTS network model using T-TSC-A clock. The diagram shows a T-GM block connected to a cloud labeled 'Partial Timing Support Network'. This cloud is connected to a T-TSC-A/O-RU GNSS Assisted block. A PRTC (GNSS) block is also connected to the T-TSC-A/O-RU GNSS Assisted block.](4ba5ec9b848aca9a957c057e0389a988_img.jpg) + +``` + +graph LR + TGM[T-GM] --> PTSN((Partial Timing Support Network)) + PTSN --> TTSCA[T-TSC-A/O-RU GNSS Assisted] + PRTC[PRTC (GNSS)] --> TTSCA + +``` + +Figure 6.2.3-1: APTS network model using T-TSC-A clock. The diagram shows a T-GM block connected to a cloud labeled 'Partial Timing Support Network'. This cloud is connected to a T-TSC-A/O-RU GNSS Assisted block. A PRTC (GNSS) block is also connected to the T-TSC-A/O-RU GNSS Assisted block. + +**Figure 6.2.3-1: APTS network model using T-TSC-A clock** + +In the model shown in Figure 6.2.3-1, the T-TSC-A (Telecom Time Synchronous Clock Assisted) would have GNSS as primary source and backup can be PTP based on Phase or Frequency from T-GM. This model would fall under LLS-C4 as per CUS specification [33]. + +**Reco:** This ORAN specification does not recommend deployment as shown in Figure 6.2.3-1 with T-TSC-A with dedicated GNSS receivers installed and expect to support 130 ns between the co-located O-RUs. It is optional to exercise this model in cases where relative time error is 260 ns or larger. + +![Figure 6.2.3-2: APTS network model using T-BC-A clock. The diagram shows a T-GM block connected to a cloud labeled 'PTS network'. This cloud is connected to a T-BC-A GNSS Assisted block. A PRTC (GNSS) block is also connected to the T-BC-A GNSS Assisted block. The T-BC-A GNSS Assisted block is connected to a cloud labeled 'FTS Network', which is then connected to a T-TSC/O-RU block.](f2dd516356b471fe9cce652a8ce7d94c_img.jpg) + +``` + +graph LR + TGM[T-GM] --> PTSN((PTS network)) + PTSN --> TBCA[T-BC-A GNSS Assisted] + PRTC[PRTC (GNSS)] --> TBCA + TBCA --> FTSN((FTS Network)) + FTSN --> TTSC[T-TSC/O-RU] + +``` + +Figure 6.2.3-2: APTS network model using T-BC-A clock. The diagram shows a T-GM block connected to a cloud labeled 'PTS network'. This cloud is connected to a T-BC-A GNSS Assisted block. A PRTC (GNSS) block is also connected to the T-BC-A GNSS Assisted block. The T-BC-A GNSS Assisted block is connected to a cloud labeled 'FTS Network', which is then connected to a T-TSC/O-RU block. + +**Figure 6.2.3-2: APTS network model using T-BC-A clock** + +In the model shown in Figure 6.2.3-2 the T-BC-A (Telecom Boundary Clock Assisted) use GNSS as primary source and network based PTP as backup over Partial timing support network. The T-BC-A to T-TSC will be Full timing support network + +**Reco:** This specification recommends deployment as shown in Figure 6.2.3-2 with T-BC-A in case relative time alignment error between two O-RU is less than 130nsec. + +### 6.2.4 Profile comparison table with important attributes + +| Attribute | G.8275.1 (FTS) | G.8275.2 (PTS) | G.8265.1 | +|-----------------------------------------------------------------------------------|-----------------------------------------------------------------------------|--------------------------------------|---------------------------------------| +| Transport | PTP over Ethernet Multicast | PTP over IPv4 or IPv6 unicast | PTP over IPv4 unicast | +| Domain number | 24-43 | 44-63 | 4 to 23 | +| Hybrid mode of operation using Synchronous Ethernet (G.8262 [14] / G.8262.1 [15]) | Must require (Note-1) | Optional | No | +| BTCA algorithm | A-BTCA | A-BTCA | A-BTCA (Note-2) | +| PTP packet rates (PPS) | Fixed packet rate. Sync/Delay-Req/Resp messages: 16 PPS and Announce: 8 PPS | Variable (Configurable up to 128PPS) | Variable (Configurable up to 128 PPS) | +| Every hop PTP aware | Yes (Full Time Support profile) | No (Partial Timing Support) | No | +| Phase/Freq sync | Both Phase and Frequency sync | Both Phase and Frequency sync | Only Frequency Sync | +| Unicast Negotiation | No | Yes (Must) | Yes | +| PTP over VLAN | No (Note-3) | Optional | Yes | +| Optional TLVs for Link speed | No | Yes | No | +| Local Priority | Yes | Yes | No | + +**Table 6-2: PTP attributes comparison across various timing profiles** + +**Note-1/Reco:** Sync-E is must for T-BC (Telecom Boundary Clock), and it is optional for T-TSC built into O-RU + +Note-2: G.8275.1 [1] and G.8275.2 [3] uses same A-BTCA whereas G.8265.1 [10] uses different A-BTCA + +Note-3: PTP over VLAN is allowed for Transparent Clock compliance to G.8273.3 [4]. But not for G.8273.2 [2] based Ordinary or Boundary Clocks. + +Note-4: G.8265.1 Profile shall not be applicable in O-RAN. It is specified in the above table for completeness. + +### 6.2.5 Inter-working (IWF) function + +An Interworking function (IWF), containing a clock among other functions, would be needed to translate from one profile to the other profile. + +ITU-T standard G.8271.2 [9] and G.8275 [41] defines two types of Interworking functions (IWF) namely: IWF F-P and IWF P-F, Related performance aspects of a network with IWF is for further study in ITU-T standards. + +#### IWF F-P (Full timing support to Partial timing support) + +An interworking function (IWF), containing a clock among other functions, would be needed to translate from the FTS profile [1] to the PTS profile [3] going downstream from the T-GM towards the end application. + +![Figure 6.2.5-1: IWF F-P network model. The diagram shows a flow from T-GM (black rectangle) to FTS (orange cloud), then to IWF F-P (black rectangle), then to PTS (orange cloud), and finally to O-RU/T-TSC (black rectangle). Arrows indicate the direction of flow between these components.](685cd83706e5674b057f71ecee7b509d_img.jpg) + +``` + +graph LR + TGM[T-GM] --> FTS((FTS)) + FTS --> IWF_F_P[IWF F-P] + IWF_F_P --> PTS((PTS)) + PTS --> O_RU_T_TSC[O-RU/T-TSC] + +``` + +Figure 6.2.5-1: IWF F-P network model. The diagram shows a flow from T-GM (black rectangle) to FTS (orange cloud), then to IWF F-P (black rectangle), then to PTS (orange cloud), and finally to O-RU/T-TSC (black rectangle). Arrows indicate the direction of flow between these components. + +Figure 6.2.5-1: IWF F-P network model + +#### IWF P-F (Partial Timing support to Full timing support) + +An inter-working function (IWF P-F), containing a clock among other functions, would be needed to translate from the partial timing support profile [3] to the full timing support profile [1] going downstream from the T-GM towards the End Application. + +![Figure 6.2.5-2: IWF P-F network model. The diagram shows a flow from T-GM (black rectangle) to PTS (orange cloud), then to IWF P-F (black rectangle), then to FTS (orange cloud), and finally to O-RU/T-TSC (black rectangle). Arrows indicate the direction of flow between these components.](cec680ac6d537a2dd657415399e9bcb2_img.jpg) + +``` + +graph LR + TGM[T-GM] --> PTS((PTS)) + PTS --> IWF_P_F[IWF P-F] + IWF_P_F --> FTS((FTS)) + FTS --> O_RU_T_TSC[O-RU/T-TSC] + +``` + +Figure 6.2.5-2: IWF P-F network model. The diagram shows a flow from T-GM (black rectangle) to PTS (orange cloud), then to IWF P-F (black rectangle), then to FTS (orange cloud), and finally to O-RU/T-TSC (black rectangle). Arrows indicate the direction of flow between these components. + +Figure 6.2.5-2: IWF P-F network model + +##### Reco: + +- In order to support relative time error requirements in a cluster of base stations, this ORAN specification recommends only IWF P-F for the X-haul transport under the assumption that the cooperating O-RUs are connected with full timing support network. +- Not recommended to use IWF P-F for the purpose of synchronizing geographically distributed O-RUs within 260 ns (note: This is the most stringent requirement applicable to geographically distributed O-RUs). +- 5G front-haul synchronization requirements like Category B applications need high precise time alignment error (TAE) between radio units (i.e., 260 ns), only Full timing support network can be used to achieve it. + +**Reco:** Whenever partial timing support is exercised, the PTP packets must be prioritized [refer 0]. + +### 6.2.6 A-BTCA algorithm and PTP attributes to consider + +Both G.8275.1 [1] and G.8275.2 [3] profiles use Alternate Best TimeTransmitter Clock Algorithm (A-BTCA). Some of the key attributes of this A-BTCA algorithm against the standard 1588v2 defined BTCA algorithm given below: + +| PTP Attributes | A-BTCA (G.8275.1 & G.8275.2) | BTCA (IEEE1588v2) | +|----------------------------------|-----------------------------------------------------------------------------------------|------------------------------------| +| <b>TimeTransmitter only port</b> | Allowed and very useful to design the synchronization network | Not applicable | +| <b>Multiple Active GMs</b> | Allows to load balance the PTP timeReceivers across the GMs | Does not allow multiple active GMs | +| <b>Local priority</b> | Pert port attribute, very powerful parameter to design the synchronization network flow | Not applicable | +| <b>Priority-1</b> | Not used for clock selection | Used for clock selection | + +**Table 6-3: PTP attributes to consider for A-BTCA algorithm.** + +## 6.3 Synchronization time error budgeting model + +### 6.3.1 Factors to be considered for network synchronization budgeting + +#### 6.3.1.1 SyncE/Physical layer clock switchover and phase transient + +- A rearrangement of the PHY frequency (Sync-E) results in the phase/time error at each T-BC, the T-TSC and the end application. +- The TE is generally larger in the congruent scenario than in the non-congruent scenario because in the congruent scenario each T-BC has errors due to the re-arrangement transient in both time and frequency planes. +- The frequency plane error is due to PHY frequency input and time/phase error due to PTP sync messages input to a T-BC from the upstream T-BC. +- Refer Figure II.3 for congruent scenario and II.4 for non-congruent scenario in ITU-T G.8271.1 [8] standard. +- Refer ITU-T G.8271.1 - Appendix-V1: Mitigation of time error due to synchronous ethernet transients. +- Refer ITU-T G.8273.2 [2] – Annex-B: Control of the phase transient due to rearrangements in the synchronous ethernet network + +![Figure 6.3.1-1: Congruent network model. This diagram shows a linear network topology. On the left is a black box labeled 'T-GM'. It is connected by a solid blue arrow to a black box labeled 'T-BC'. This 'T-BC' is connected by a solid blue arrow to another black box labeled 'T-BC'. This second 'T-BC' is connected by a solid blue arrow to a third black box labeled 'T-BC'. Finally, this third 'T-BC' is connected by a solid blue arrow to a black box on the right labeled 'O-RU/ T-TSC'. There are also dashed green arrows between the 'T-GM' and the first 'T-BC', between the first 'T-BC' and the second 'T-BC', and between the second 'T-BC' and the 'O-RU/ T-TSC'. A callout box labeled 'Sync-E' has a blue arrow pointing to the dashed green arrow between the second and third 'T-BC' boxes. Another callout box labeled 'PTP' has a blue arrow pointing to the dashed green arrow between the first and second 'T-BC' boxes.](ffddc0866e71ca35a9546ac9d27c9d01_img.jpg) + +Figure 6.3.1-1: Congruent network model. This diagram shows a linear network topology. On the left is a black box labeled 'T-GM'. It is connected by a solid blue arrow to a black box labeled 'T-BC'. This 'T-BC' is connected by a solid blue arrow to another black box labeled 'T-BC'. This second 'T-BC' is connected by a solid blue arrow to a third black box labeled 'T-BC'. Finally, this third 'T-BC' is connected by a solid blue arrow to a black box on the right labeled 'O-RU/ T-TSC'. There are also dashed green arrows between the 'T-GM' and the first 'T-BC', between the first 'T-BC' and the second 'T-BC', and between the second 'T-BC' and the 'O-RU/ T-TSC'. A callout box labeled 'Sync-E' has a blue arrow pointing to the dashed green arrow between the second and third 'T-BC' boxes. Another callout box labeled 'PTP' has a blue arrow pointing to the dashed green arrow between the first and second 'T-BC' boxes. + +Figure 6.3.1-1: Congruent network model + +![Figure 6.3.1-2: Non-congruent network model. This diagram shows a more complex network topology. At the top, there are four black boxes in a row: 'T-GM', 'T-BC', 'T-BC', and 'O-RU/ T-TSC'. They are connected by solid blue arrows from left to right. Below each of these top boxes is a vertical stack of three black ovals. Under 'T-GM' are 'EEC' and 'PRC'. Under the first 'T-BC' are 'EEC' and 'PRC'. Under the second 'T-BC' are 'EEC' and 'PRC'. Under 'O-RU/ T-TSC' are 'EEC' and 'PRC'. Red dashed arrows point upwards from each 'PRC' oval to its corresponding 'EEC' oval, and from each 'EEC' oval to its corresponding top box. A callout box labeled 'Sync-E' has a blue arrow pointing to the red dashed arrow between the 'EEC' and 'PRC' ovals under the first 'T-BC'. Another callout box labeled 'PTP' has a blue arrow pointing to the dashed green arrow between the first and second 'T-BC' boxes at the top.](47cddab42f3d3d5997664ac3dbd6817a_img.jpg) + +Figure 6.3.1-2: Non-congruent network model. This diagram shows a more complex network topology. At the top, there are four black boxes in a row: 'T-GM', 'T-BC', 'T-BC', and 'O-RU/ T-TSC'. They are connected by solid blue arrows from left to right. Below each of these top boxes is a vertical stack of three black ovals. Under 'T-GM' are 'EEC' and 'PRC'. Under the first 'T-BC' are 'EEC' and 'PRC'. Under the second 'T-BC' are 'EEC' and 'PRC'. Under 'O-RU/ T-TSC' are 'EEC' and 'PRC'. Red dashed arrows point upwards from each 'PRC' oval to its corresponding 'EEC' oval, and from each 'EEC' oval to its corresponding top box. A callout box labeled 'Sync-E' has a blue arrow pointing to the red dashed arrow between the 'EEC' and 'PRC' ovals under the first 'T-BC'. Another callout box labeled 'PTP' has a blue arrow pointing to the dashed green arrow between the first and second 'T-BC' boxes at the top. + +Figure 6.3.1-2: Non-congruent network model + +Note: As per CUS specification [33] Sync-E phase transient is not considered for fronthaul networks + +#### 6.3.1.2 End application synchronization requirements + +Based on the O-RAN topology being referred end application can be either O-DU, O-RU or O-DU and O-RU. + +##### 6.3.1.2.1 Sync requirements for O-RU in LLS-C1/C2/C3/C4 topology: + +Frequency and time errors are measured on the Air interface at the O-RU output should be within specified limits refer CUS specification [33]. + +The performance of the Air interface is usually impacted by below metrics: + +1. Maximum absolute time alignment error: This is the maximum time error at the output of Radio ports off from the PTP Grandmaster. +2. Maximum relative time alignment error: This is the maximum time error between two radio ports of same or different O-RUs. +3. Air interface Frequency error: The O-RAN fronthaul network shall ensure O-RU meeting +/-50ppb air interface frequency error requirement as per 3GPP specification which is the short-term average error in 1ms duration. Applicable to both LTE and 5G technologies. + +Below are few of the recommendations or best practices to keep Absolute and Relative time error within the defined limit. + +###### A. O-RUs connected to same clock reference: + +It is usually recommended to have O-RUs connected to the same clock source in order to avoid any time error differences. If multiple switches are involved in the path from DU to RU, it is recommended to use Class-C or better T-BCs to meet the time alignment errors between O-RUs + +![Diagram illustrating the LLS-C3 topology where O-RUs are connected to an O-DU through multiple T-BCs. The O-DU is connected to two T-BCs (T-BC1 and T-BC2). T-BC1 is connected to O-RU1 and O-RU2. T-BC2 is connected to O-RU3 and O-RU4.](105490b7572a33e9d410ad2d4abe3587_img.jpg) + +``` + +graph LR + ODU[O-DU] --> TBC1[T-BC1] + ODU --> TBC2[T-BC2] + TBC1 --> ORU1[O-RU1] + TBC1 --> ORU2[O-RU2] + TBC2 --> ORU3[O-RU3] + TBC2 --> ORU4[O-RU4] + +``` + +Diagram illustrating the LLS-C3 topology where O-RUs are connected to an O-DU through multiple T-BCs. The O-DU is connected to two T-BCs (T-BC1 and T-BC2). T-BC1 is connected to O-RU1 and O-RU2. T-BC2 is connected to O-RU3 and O-RU4. + +**Figure 6.3.1-3: O-RU connected to O-DU through multiple T-BCs (LLS-C3 topology)** + +###### B. Holdover characteristics: + +Usually O-RUs will not have good holdover characteristics and in such cases its recommended to have O-RU tracking upstream PTP TimeTransmitter (O-DU or intermediate switches) which should be equipped with oscillators having good holdover characteristics. + +###### C. Shorter chain of clocks: + +To keep the absolute time error less and frequency error (low noise) within the limits at the input of O-RU, it is recommended to have fewer number of hops on the path from T-GM towards O-RU in LLS-C3/C2 topologies. Refer to the guidelines proposed in CUS spec [33] + +###### D. Mixed O-RAN topology: + +Topologies with mixed modes (LLS-C1/LLS-C4) would attract time error differences at the output of O-RUs and this impacting the Air interface intended target performance. Hence it is recommended to avoid the mixed O-RAN topologies. + +![Figure 6.3.1-4: O-RUs connected in mixed RAN topology in LLS-C1/C4 modes. The diagram shows an O-DU connected to two O-RUs: O-RU1(C1) and O-RU4(C4). The link between O-DU and O-RU1(C1) is labeled C/U/S/M. The link between O-DU and O-RU4(C4) is labeled C/U/M. O-RU4(C4) is also connected to a GNSS symbol.](e7ce6d5c87461bffbb1c380e27d630f7_img.jpg) + +Figure 6.3.1-4: O-RUs connected in mixed RAN topology in LLS-C1/C4 modes. The diagram shows an O-DU connected to two O-RUs: O-RU1(C1) and O-RU4(C4). The link between O-DU and O-RU1(C1) is labeled C/U/S/M. The link between O-DU and O-RU4(C4) is labeled C/U/M. O-RU4(C4) is also connected to a GNSS symbol. + +Figure 6.3.1-4: O-RUs connected in mixed RAN topology in LLS-C1/C4 modes + +###### E. PTP Hybrid (PTP + SyncE/eSyncE) network: + +In order to have accurate and stable S-Plane on O-RUs, it is recommended to have PTP and SyncE/eSyncE for Phase/Time and Frequency recovery on O-RU for achieving better time error accuracy(absolute/relative) at the outputs of O-RUs. It is also recommended to have the O-RU equipped with better jitter/wander filtering capabilities to keep the noise especially at lower frequencies as low as possible. In otherwords, if SyncE is used, the O-RU must have appropriate low pass filtering to reject SyncE jitter, and if not used then O-RU must implement a stable local oscillator. + +![Figure 6.3.1-5: O-DU/O-RUs connected in LLS-C1 topology with FH link carrying PTP + SyncE. The diagram shows an O-DU connected to two O-RUs: O-RU1 and O-RU2. Both links are labeled C/U/S/M.](695af1fb0ea39438d5916ba27413a596_img.jpg) + +Figure 6.3.1-5: O-DU/O-RUs connected in LLS-C1 topology with FH link carrying PTP + SyncE. The diagram shows an O-DU connected to two O-RUs: O-RU1 and O-RU2. Both links are labeled C/U/S/M. + +Figure 6.3.1-5: O-DU/O-RUs connected in LLS-C1 topology with FH link carrying PTP + SyncE + +##### 6.3.1.2.2 Sync requirements for O-DU in LLS-C1/C2/C3 topology: + +Below are few of the recommendations or best practices to be taken care from O-RU side to keep Absolute and Relative time error within the defined limit at the output of O-RUs. + +###### A. Shorter chain of Clocks: + +To keep the absolute time error less with budget for short term holdovers, it is recommended to have O-DU as clock source acting as T-GM or O-DU acting as T-BC/IWF with smaller number of hops in the path reaching to T-GM in LLS-C1/LLS-C2 topology. + +###### B. Clock source redundancy: + +In order to avoid the disruptions to cells during the GNSS faults on O-DU acting as T-GM, its recommended to have O-DU recovering the clock from remote T-GM on Midhaul / Fronthaul and thus acting as T-BC with preferably with G.8275.1(FTS) [1] or alternatively G.8275.2(PTS) [3] or T-GM with frequency assist. + +###### C. Holdover characteristics: + +In order to avoid the disruptions to cells during the GNSS faults on T-GM (O-DU or remote T-GM) where there is no back-up, it is recommended to have O-DU equipped with longer Holdover durations allowing time for operators to fix any GNSS failures. + +###### D. M-Plane monitoring: + +In the event of malfunctioning of any of the connecting O-RUs, it is recommended to report such events from O-RU to O-DU, identify, isolate the faulty O-RU and continue to operate with the other connected O-RUs. This can be done by using available M-plane sync status information. + +![Diagram illustrating M-Plane monitoring between O-DU and O-RUs. An O-DU block on the left is connected to four O-RU blocks (O-RU1, O-RU2, O-RU3, O-RU4) on the right. Bidirectional arrows connect O-DU to each O-RU. A red 'X' is placed over the connection to O-RU4, indicating a fault or isolation.](f60b6e96db1c1bc475f8f0e90c8d0bd8_img.jpg) + +``` + +graph LR + ODU[O-DU] <--> ORU1[O-RU1] + ODU <--> ORU2[O-RU2] + ODU <--> ORU3[O-RU3] + ODU <--> ORU4[O-RU4] + style ORU4 stroke-dasharray: 5 5 + +``` + +Diagram illustrating M-Plane monitoring between O-DU and O-RUs. An O-DU block on the left is connected to four O-RU blocks (O-RU1, O-RU2, O-RU3, O-RU4) on the right. Bidirectional arrows connect O-DU to each O-RU. A red 'X' is placed over the connection to O-RU4, indicating a fault or isolation. + +Figure 6.3.1-6: Monitoring O-DU/O-RUs over M Plane + +#### 6.3.1.3 Class of devices and time errors + +The noise generation of a T-GM/T-BC and a T-TSC represents the amount of noise produced at the output of the T-GM/T-BC/T-TSC when there is an ideal input reference packet timing signal. Under normal, locked operating conditions, the time output of the T-BC and the T-TSC should be accurate to within the maximum absolute time error (TE) ( $\max|TE|$ ). This value includes all the noise components, i.e., the constant time error (cTE) and the dynamic time error (dTE) noise generation. + +In order to support different performance requirements at the end application specified in ITU-T G.8271 [7] specification using different network topologies and network technologies, the maximum absolute time error, the time error and dTE noise generation requirements for T-GM / T-BCs and T-TSCs are divided into multiple classes. + +At the precision time protocol (PTP) and 1 pulse per second (PPS) outputs, the maximum absolute time error ( $\max|TE|$ ) for T-BC/T-TSC is shown in below table. This includes all time error components (unfiltered). + +##### T-GM + +| No | Parameters | Conditions | Class A | Class B | +|----|-----------------------|------------------------------------------------------------------|-------------------------------|----------------------------| +| 1 | Max TE | 1pps: unfiltered, PTP: 100-sample moving average low-pass filter | 100ns | 40ns | +| 2 | dTE <sub>L</sub> MTIE | 1pps: unfiltered, PTP: 100-sample moving average low-pass filter | 100ns max | 40ns max | +| 3 | dTE <sub>L</sub> TDEV | 1pps: unfiltered, PTP: 100-sample moving average low-pass filter | 3ns, raising to 30ns @ 1000s. | 1ns, raising to 5ns @ 500s | + +**Table 6-4: T-GM types and performance metrics** + +##### T-BC/T-TSC + +| No | Parameters | Conditions | Class A | Class B | Class C | Class D | +|----|-----------------------|-----------------------------|----------|----------|----------|---------| +| 1 | Max TE | Unfiltered 1000s. | 100ns | 70ns | 30ns | FFS | +| 2 | Max TE <sub>L</sub> | 0.1Hz LPF 1000s measurement | - | - | - | 5ns | +| 3 | cTE | Averaged over 1000s | +/- 50ns | +/- 20ns | +/- 10ns | FFS | +| 4 | dTE <sub>L</sub> MTIE | 0.1Hz LPF const temp 1000s | 40ns | 40ns | 10ns | FFS | +| 5 | dTE <sub>L</sub> TDEV | 0.1Hz LPF const temp 1000s | 4ns | 4ns | 2ns | FFS | +| 6 | dTE <sub>H</sub> | 0.1Hz HPF const temp 1000s | 70ns | 70ns | 30ns | FFS | + +**Table 6-5: T-BC/T-TSC clock types and performance metrics** + +### 6.3.2 Time Error budget calculation + +#### 6.3.2.1 General Budgeting model + +When time error budget is calculated there are three different aspects to that: + +1. Time Error from Time source (Ex. T-GM) to O-RU (Input to O-RU and up until Radio Interface) +2. Time Error from Time source (Ex: T-GM) to O-DU +3. Time Error between O-RU to O-RU radio interfaces – Also called as Relative Time Alignment Error (TAE). + +For each type described above one needs to start with overall time error budget as the end number to start with and calculate back by subtracting the individual budgets for each of the following that are applicable: + +1. Half of asymmetry (caused by Network, Fiber, Wavelength used or Optics) +2. Holdover budget (for Radio, Network nodes, GM or combination of these) +3. Number of hops and cTE and dTE<sub>L</sub> of each of the network nodes based on clock types and time error of T-GM/PRTC based on PRTC type. +4. Sync-E/Physical layer clock switchover phase error + +For example: + +T : Target Time Error budget (Ex. 1.5 microseconds for TDD network) + +T(g) : time error of PRTC+GM + +T(n) : time error for all network nodes (boundary clocks) + +T(r) : time error of Radio device + +T(h) : holdover timer error budget + +T(a) : time error budget for asymmetry + +T(s) : time error budget for SyncE re-arrangement. + +T(c) : Total calculated time error budget + +Then, sum of all time errors allocated for GM, network nodes, asymmetry, holdover, SyncE re-arrangement must be less than the Total Target budget (T) to successfully plan and deploy the network (as shown below). + +$$T(c) = T(g) + T(n) + T(r) + T(h) + T(a) + T(s)$$ + +Then $T(c) < T$ + +Note1: If there are multiple PRTC/GMs in the network design the total budget T must not be exceeded whichever path and whichever GM is selected. + +Note2: Similarly, the time error must be calculated for the longest chain of network path/hops rather shortest chain of nodes to meet the Target Total budget even during network rearrangement and failover conditions. + +#### 6.3.2.2 Relative versus End-to-End network budgeting model + +##### 6.3.2.2.1 End-to-End time error budgeting + +End to End time error is calculated from PRTC/T-GM to O-RU and T-GM to O-DU + +$$\max |TE_N| \leq \sum_{i=1}^N |cTE_i| + \sum_{j=1}^{N-1} |linkTE_j| + \sqrt{\left\{ \sum_{i=1}^N \left[ \max |d^L TE_i(t)| \right]^2 \right\} + \left[ \max |d^H TE_N(t)| \right]^2}$$ + +Max|TE| - Maximum Absolute Time Error + +cTE – constant Time Error + +dTE<sub>L</sub> - dynamic Time Error low frequency + +dTE<sub>H</sub> - dynamic Time Error high frequency + +linkTE – Time Error introduced by link asymmetry + +Note: It is an approximation formula that does not include the holdover budget, asymmetry and network rearrangement time error + +###### Case-1 T-GM to Radio Interface (O-RU): + +![Figure 6.3.2-1: Time error budget model – T-GM to Radio interface. The diagram shows a network topology starting from a T-GM (Time-to-Gateway Module) on the left. A solid blue arrow points from T-GM to a CAS (Core Access Server) block. From the CAS, two solid blue arrows branch out: one to an O-DU (Open Distributed Unit) block above and one to a CSR-1 (Core Session Router) block to the right. Below the CAS, a dashed red arrow points to a CSR-2 block, which then points to an O-RU-2 / T-TSC-2 block. The CSR-1 block points to an O-RU-1 / T-TSC-1 block. A dashed red arrow also originates from the T-GM area and points towards the CSR-2 block, indicating a direct path or a specific error component.](f3427bef0e412a4ca1b581beacb95005_img.jpg) + +Figure 6.3.2-1: Time error budget model – T-GM to Radio interface. The diagram shows a network topology starting from a T-GM (Time-to-Gateway Module) on the left. A solid blue arrow points from T-GM to a CAS (Core Access Server) block. From the CAS, two solid blue arrows branch out: one to an O-DU (Open Distributed Unit) block above and one to a CSR-1 (Core Session Router) block to the right. Below the CAS, a dashed red arrow points to a CSR-2 block, which then points to an O-RU-2 / T-TSC-2 block. The CSR-1 block points to an O-RU-1 / T-TSC-1 block. A dashed red arrow also originates from the T-GM area and points towards the CSR-2 block, indicating a direct path or a specific error component. + +Figure 6.3.2-1: Time error budget model – T-GM to Radio interface + +###### Assumptions: + +- T-GM is PRTC-B = +/- 40nsec +- CAS, CSR are class-C devices (cTE= +/-10) and dTE<sub>L</sub> = 10nsec +- O-RU-1 and O-RU-2 are enhanced RU with max TE of 35nsec + +- E2E Max|TE| = maxTE(T-GM) + cTE(CAS) + cTE(CSR) + sqrt(max|dTE<sub>L</sub>(CAS)<sup>2</sup> + dTE<sub>L</sub>(CSR)<sup>2</sup>) + maxTE(O-RU) +- E2E max|TE| = 40 + 10 + 10 + sqrt(10<sup>2</sup> + 10<sup>2</sup>) + 35 => 109.14nsec => 109.14 nsec + +###### Case-2: T-GM to O-DU + +![Figure 6.3.2-2: Time error budget model – T-GM to O-DU. The diagram shows a network topology where a T-GM (Terrestrial Gateway-Mobility) connects to a CAS (Core Access Server). From the CAS, the path splits into two branches: one through CSR-1 (Core Session Router-1) to O-RU-1/T-TSC-1 (Open Radio Unit-1 / Terrestrial Switching Center-1), and another through CSR-2 (Core Session Router-2) to O-RU-2/T-TSC-2 (Open Radio Unit-2 / Terrestrial Switching Center-2). Both branches then connect to the O-DU (Open Distributed Unit). A dashed green line indicates a direct path from T-GM to O-DU via CAS, representing the time error budget model.](b55f307eb428fbf404864e795fa1fc1b_img.jpg) + +``` + +graph LR + TGM[T-GM] -- solid blue --> CAS[CAS] + CAS -- solid blue --> CSR1[CSR-1] + CAS -- solid blue --> CSR2[CSR-2] + CSR1 -- solid blue --> ORU1["O-RU-1/ +T-TSC-1"] + CSR2 -- solid blue --> ORU2["O-RU-2 / +T-TSC-2"] + ORU1 -- solid blue --> ODU[O-DU] + ORU2 -- solid blue --> ODU + TGM -. dashed green .-> CAS + CAS -. dashed green .-> ODU + +``` + +Figure 6.3.2-2: Time error budget model – T-GM to O-DU. The diagram shows a network topology where a T-GM (Terrestrial Gateway-Mobility) connects to a CAS (Core Access Server). From the CAS, the path splits into two branches: one through CSR-1 (Core Session Router-1) to O-RU-1/T-TSC-1 (Open Radio Unit-1 / Terrestrial Switching Center-1), and another through CSR-2 (Core Session Router-2) to O-RU-2/T-TSC-2 (Open Radio Unit-2 / Terrestrial Switching Center-2). Both branches then connect to the O-DU (Open Distributed Unit). A dashed green line indicates a direct path from T-GM to O-DU via CAS, representing the time error budget model. + +Figure 6.3.2-2: Time error budget model – T-GM to O-DU + +###### Assumptions: + +- T-GM is PRTC-B = +/- 40nsec +- CAS and CSR are class-C devices (cTE= +/-10) and $dTE_L = 10\text{nsec}$ +- RU-1 and RU-2 are enhanced RU with max TE of 35nsec +- DU is class-A device with cTE = +/-50 nsec + +- $E2E \text{ Max} |TE| = \text{maxTE}(T\text{-GM}) + cTE(CAS) + cTE(O\text{-DU}) + \text{sqrt}(\text{max} |dTE_L(CAS)^2|)$ +- $E2E \text{ max} |TE| = 40 + 10 + 50 + \text{sqrt}(10^2) \Rightarrow 110 \text{ nsec}$ + +##### 6.3.2.2.2 Relative time error budgeting + +Relative time error is calculated between O-RU to O-RU. Further this is typically calculated in the front-haul network. This type of time-error can be very stringent based on the front-haul application is deployed. + +Radio to Radio Interface: + +![Diagram of the Relative Time error budget model: Radio to Radio interface. The diagram shows a T-GM block connected to a CAS block. The CAS block is connected to O-DU, CSR-1, and CSR-2. CSR-1 is connected to O-RU-1/T-TSC-1, and CSR-2 is connected to O-RU-2/T-TSC-2. A dashed red arrow indicates the path from O-RU-1/T-TSC-1 to O-RU-2/T-TSC-2.](a710235b7a9880c7a1cdb2f39a123e64_img.jpg) + +``` + +graph LR + TGM[T-GM] --> CAS[CAS] + CAS --> ODU[O-DU] + CAS --> CSR1[CSR-1] + CAS --> CSR2[CSR-2] + CSR1 --> ORU1[O-RU-1 / T-TSC-1] + CSR2 --> ORU2[O-RU-2 / T-TSC-2] + ORU1 -.-> ORU2 + +``` + +Diagram of the Relative Time error budget model: Radio to Radio interface. The diagram shows a T-GM block connected to a CAS block. The CAS block is connected to O-DU, CSR-1, and CSR-2. CSR-1 is connected to O-RU-1/T-TSC-1, and CSR-2 is connected to O-RU-2/T-TSC-2. A dashed red arrow indicates the path from O-RU-1/T-TSC-1 to O-RU-2/T-TSC-2. + +**Figure 6.3.2-3: Relative Time error budget model: Radio to Radio interface** + +In this model, the time error between the two O-RUs (radio-unit) air-interface through a common T-BC (CAS) device calculated. + +Assumptions: + +- T-GM is PRTC-B = +/- 40nsec +- CAS, CSR are class-C devices (cTE= +/-10) and $dTE_L = 10\text{nsec}$ +- O-RU-1 and O-RU-2 are enhanced RU with max TE of 35nsec +- $cTE_R = 12\text{ nsec}$ and $dTE_{RL} = 14\text{ nsec}$ + +- Relative Max|TE| = $\max\text{TE}(\text{O-RU1}) + \max\text{TE}(\text{O-RU2}) + c\text{TE}(\text{CSR1}) + cTE_R(\text{CAS}) + c\text{TE}(\text{CSR2}) + \sqrt{(\max|dTE_{RL}(\text{CAS})|^2 + dTE_L(\text{CSR1})^2 + dTE_L(\text{CSR2})^2)}$ +- Relative max|TE| = $35 + 35 + 10 + 12 + 10 + \sqrt{14^2 + 10^2 + 10^2} \Rightarrow 121.89\text{ nsec}$ + + + +#### 6.3.3.2 Config LLS-C1 (Option B: T-GM directly connected to O-DU) + +![Figure 6.3.3-2: T-GM directly connected to O-DU. This diagram illustrates the timing and connectivity for Option B of LLS-C1 configuration. It shows a PRTC/ePRTC T-GM connected to two distribution sites, each containing an O-DU and an integrated BC or IWF. These are then connected to remote sites with O-RUs and T-TSCs. Timing constraints are shown for various paths, including PTP/SyncE paths and TAE. A note states: 'Figure is for illustrative purpose and does not provide deployment guidance (for example the number of T-BCs/T-TCs* in a clock chain and network topology)'.](a7c910e4898c1bcfbf912a36cb8599eb_img.jpg) + +Figure 6.3.3-2: T-GM directly connected to O-DU. The diagram shows a PRTC/ePRTC T-GM connected to two distribution sites. Each distribution site contains an O-DU and an integrated BC or IWF. These are connected to remote sites with O-RUs and T-TSCs. Timing constraints are shown for various paths, including PTP/SyncE paths and TAE. A note states: "Figure is for illustrative purpose and does not provide deployment guidance (for example the number of T-BCs/T-TCs\* in a clock chain and network topology)". + +Figure 6.3.3-2: T-GM directly connected to O-DU. This diagram illustrates the timing and connectivity for Option B of LLS-C1 configuration. It shows a PRTC/ePRTC T-GM connected to two distribution sites, each containing an O-DU and an integrated BC or IWF. These are then connected to remote sites with O-RUs and T-TSCs. Timing constraints are shown for various paths, including PTP/SyncE paths and TAE. A note states: 'Figure is for illustrative purpose and does not provide deployment guidance (for example the number of T-BCs/T-TCs\* in a clock chain and network topology)'. + +**Figure 6.3.3-2: T-GM directly connected to O-DU** + +In this LLS-C1 config, Option-B model, O-DU is acting as integrated BC/IWF and sources the time/clock from external T-GM and acts as the timing timeTransmitter to downstream O-RU. + +#### 6.3.3.3 Config LLS-C1 (Option C: T-GM connected to O-DU via chain of network nodes) + +![Figure 6.3.3-3: T-GM connected to O-DU over chain of network nodes. This diagram illustrates the timing and connectivity for Option C of LLS-C1 configuration. It shows a PRTC/ePRTC T-GM connected to a chain of network nodes (T-BC, T-TC*) which then connects to two distribution sites. Each distribution site contains an O-DU and an integrated BC or IWF. These are then connected to remote sites with O-RUs and T-TSCs. Timing constraints are shown for various paths, including PTP/SyncE paths and TAE. A note states: 'Figure is for illustrative purpose and does not provide deployment guidance (for example the number of T-BCs/T-TCs* in a clock chain and network topology)'.](01535cceff9710f3eaac2f06712415d8_img.jpg) + +Figure 6.3.3-3: T-GM connected to O-DU over chain of network nodes. The diagram shows a PRTC/ePRTC T-GM connected to a chain of network nodes (T-BC, T-TC\*) which then connects to two distribution sites. Each distribution site contains an O-DU and an integrated BC or IWF. These are connected to remote sites with O-RUs and T-TSCs. Timing constraints are shown for various paths, including PTP/SyncE paths and TAE. A note states: "Figure is for illustrative purpose and does not provide deployment guidance (for example the number of T-BCs/T-TCs\* in a clock chain and network topology)". + +Figure 6.3.3-3: T-GM connected to O-DU over chain of network nodes. This diagram illustrates the timing and connectivity for Option C of LLS-C1 configuration. It shows a PRTC/ePRTC T-GM connected to a chain of network nodes (T-BC, T-TC\*) which then connects to two distribution sites. Each distribution site contains an O-DU and an integrated BC or IWF. These are then connected to remote sites with O-RUs and T-TSCs. Timing constraints are shown for various paths, including PTP/SyncE paths and TAE. A note states: 'Figure is for illustrative purpose and does not provide deployment guidance (for example the number of T-BCs/T-TCs\* in a clock chain and network topology)'. + +**Figure 6.3.3-3: T-GM connected to O-DU over chain of network nodes** + +In this LLS-C1 config, option-C model, there are chain of T-BCs in between T-GM and O-DU nodes. In this case T-GM may present in Mid/Back-haul and multiple T-BCs chain of nodes deployed between T-GM and O-DU nodes. + +#### 6.3.3.4 Config LLS-C2 (Option A: O-DU is the nearest common T-BC) + +![Figure 6.3.3-4: O-DU is the nearest common T-BC](452802d7932569eac75b018d1bb33d45_img.jpg) + +Figure is for illustrative purpose and does not provide deployment guidance (for example the number of T-BCs/T-TCs\* in a clock chain and network topology). + +PTP/SyncE path + +nearest common BC + +distribution site + +O-DU + +integrated BC or IWF + +T-BC T-TC\* + +0 or more T-BCs/T-TCs\* in the clock chain + +remote site + +O-RU (enhanced) + +T-TSC + +|TE| ≤ 35 ns + +O-RU (enhanced) + +T-TSC + +|TE| ≤ 35 ns + +ITU-T G.8271 + +TAE + +(FR1) 130-260 ns + +(FR2) 130-260 ns + +3000 ns + +The budgeting examples are based on the conservative assumption of linear accumulation between the 2 branches relevant to the TAE requirement. + +(FR2) (FR1) ±30...95 ns + +(FR2) (FR1) ±65...130 ns + +nearest common BC + +distribution site + +O-DU + +integrated BC or IWF + +T-BC T-TC\* + +0 or more T-BCs/T-TCs\* in the clock chain + +remote site + +O-RU (regular) + +T-TSC + +|TE| ≤ 80 ns + +O-RU (regular) + +T-TSC + +|TE| ≤ 80 ns + +(FR1) 260 ns + +(FR1): NR intra-band continuous carrier aggregation in FR1 + +(FR2): NR intra-band continuous carrier aggregation in FR2 (co-located RUs only) + +±30...100 ns + +±1100 ns + +±1325 ns + +±1500 ns + +(FR1) ±50 ns + +(FR1) ±130 ns + +Figure 6.3.3-4: O-DU is the nearest common T-BC + +**Figure 6.3.3-4: O-DU is the nearest common T-BC** + +In this LLS-C2 config, with option-A model, O-DU and O-RU are separated by one or more T-BCs in the middle. Further O-DU continue to act as common BC for the O-RUs. + +Note: the time error budget allocation to support FR1 and FR2 requirements shown in this diagram is not according to the methodology presented in 6.3.2.2.2 but rather presents a conservative estimation. This is the same approach currently followed in the CUS specification [33] + +#### 6.3.3.5 Config LLS-C2 (Option B: nearest common T-BC not O-DU) + +![Figure 6.3.3-5: O-DU not the nearest common T-BC. This diagram illustrates a network topology for LLS-C2 Option B. A central PRTC/ePRTC T-GM (A) is connected via PTP/SyncE paths to two distribution sites (B). Each distribution site contains an O-DU and an integrated BC or IWF. These are connected to T-BCs, which are the nearest common time transmitters for the remote sites (C). The remote sites contain O-RUs (enhanced or regular) and T-TSCs. Timing requirements are shown for FR1 and FR2, with a total TAE of 3000 ns. Budgeting examples are provided for the clock chain and network topology.](5355962609510023680ac0f97c3564e2_img.jpg) + +Figure 6.3.3-5: O-DU not the nearest common T-BC. The diagram shows a network topology where the nearest common time transmitter (T-BC) is not the O-DU. The PRTC/ePRTC T-GM (A) is connected to two distribution sites (B) via PTP/SyncE paths. Each distribution site contains an O-DU and an integrated BC or IWF. These are connected to T-BCs, which are the nearest common time transmitters for the remote sites (C). The remote sites contain O-RUs (enhanced or regular) and T-TSCs. Timing requirements are shown for FR1 and FR2, with a total TAE of 3000 ns. Budgeting examples are provided for the clock chain and network topology. + +Figure 6.3.3-5: O-DU not the nearest common T-BC. This diagram illustrates a network topology for LLS-C2 Option B. A central PRTC/ePRTC T-GM (A) is connected via PTP/SyncE paths to two distribution sites (B). Each distribution site contains an O-DU and an integrated BC or IWF. These are connected to T-BCs, which are the nearest common time transmitters for the remote sites (C). The remote sites contain O-RUs (enhanced or regular) and T-TSCs. Timing requirements are shown for FR1 and FR2, with a total TAE of 3000 ns. Budgeting examples are provided for the clock chain and network topology. + +Figure 6.3.3-5: O-DU not the nearest common T-BC + +In this LLS-C2 config, option-B model, the nearest common node is T-BC for the O-RUs rather O-DU. Note: the time error budget allocation to support FR1 and FR2 requirements shown in this diagram is not according to the methodology presented in 6.3.2.2.2, but rather presents a conservative estimation. This is the same approach currently followed in the CUS specification [33] + +#### 6.3.3.6 Config LLS-C3 (Option A: T-GM is the nearest common timeTransmitter) + +![Figure 6.3.3-6: T-GM is the nearest common timeTransmitter. This diagram illustrates a network topology for LLS-C3 Option A. A central PRTC/ePRTC T-GM (A) is connected via PTP/SyncE paths to two distribution sites (B). Each distribution site contains an O-DU and a T-TSC. These are connected to T-BCs, which are the nearest common time transmitters for the remote sites (C). The remote sites contain O-RUs (enhanced or regular) and T-TSCs. Timing requirements are shown for FR1 and FR2, with a total TAE of 3000 ns. Budgeting examples are provided for the clock chain and network topology.](16c4a4d12fe1b9787ef9520c16bba17c_img.jpg) + +Figure 6.3.3-6: T-GM is the nearest common timeTransmitter. The diagram shows a network topology where the T-GM is the nearest common time transmitter. The PRTC/ePRTC T-GM (A) is connected to two distribution sites (B) via PTP/SyncE paths. Each distribution site contains an O-DU and a T-TSC. These are connected to T-BCs, which are the nearest common time transmitters for the remote sites (C). The remote sites contain O-RUs (enhanced or regular) and T-TSCs. Timing requirements are shown for FR1 and FR2, with a total TAE of 3000 ns. Budgeting examples are provided for the clock chain and network topology. + +Figure 6.3.3-6: T-GM is the nearest common timeTransmitter. This diagram illustrates a network topology for LLS-C3 Option A. A central PRTC/ePRTC T-GM (A) is connected via PTP/SyncE paths to two distribution sites (B). Each distribution site contains an O-DU and a T-TSC. These are connected to T-BCs, which are the nearest common time transmitters for the remote sites (C). The remote sites contain O-RUs (enhanced or regular) and T-TSCs. Timing requirements are shown for FR1 and FR2, with a total TAE of 3000 ns. Budgeting examples are provided for the clock chain and network topology. + +Figure 6.3.3-6: T-GM is the nearest common timeTransmitter + +In this LLS-C3 config, Option-A model, O-DU is no more source of timing to O-RUs. Both O-DU and O-RU sources the time/phase from the T-GM located in the front-haul network. Further, this T-GM is acting as common timeTransmitter node to the O-RUs. + +Note: the time error budget allocation to support FR1 and FR2 is described in 6.3.2.2.2. Details can be found in G.8271.1 [8] Appendix XII, Examples of design options for fronthaul and clusters of base stations. + +#### 6.3.3.7 Config LLS-C3 (Option B: nearest common timeTransmitter is not T-GM) + +![Figure 6.3.3-7: Nearest common timeTransmitter is not T-GM. This diagram illustrates a timing architecture for LLS-C3 Option B. It shows a central front-haul network containing a PRTC/ePRTC T-GM and several T-BCs. Two distribution sites (O-DU with T-TSC) are connected via PTP/SyncE paths to the T-BCs. Two remote sites (O-RU with T-TSC) are also connected. Timing budgets are specified for various components: PRTC A (|TE| ≤ 100 ns), PRTC B (|TE| ≤ 40 ns), ePRTC (|TE| ≤ 30 ns), T-BC (|TE| ≤ 30 ns), and T-TSC (|TE| ≤ 35 ns or 80 ns). The diagram shows the accumulation of timing errors along the paths from the T-GM to the O-RUs. Key timing requirements include ±30...100 ns for the T-GM, ±30...95 ns for the T-BC, and ±65...130 ns for the T-TSC. The total timing error budget (TAE) is shown as 3000 ns. The diagram also indicates that the budgeting examples are based on the conservative assumption of linear accumulation between the 2 branches relevant to the TAE requirement. A note states: 'Figure is for illustrative purpose and does not provide deployment guidance (for example the number of T-BCs/T-TSCs* in a clock chain and network topology)'. A legend defines (FR1) as NR intra-band continuous carrier aggregation in FR1 and (FR2) as NR intra-band continuous carrier aggregation in FR2 (co-located RUs only).](49ae14c1e7b3499ba1adb2451ee37363_img.jpg) + +Figure 6.3.3-7: Nearest common timeTransmitter is not T-GM. This diagram illustrates a timing architecture for LLS-C3 Option B. It shows a central front-haul network containing a PRTC/ePRTC T-GM and several T-BCs. Two distribution sites (O-DU with T-TSC) are connected via PTP/SyncE paths to the T-BCs. Two remote sites (O-RU with T-TSC) are also connected. Timing budgets are specified for various components: PRTC A (|TE| ≤ 100 ns), PRTC B (|TE| ≤ 40 ns), ePRTC (|TE| ≤ 30 ns), T-BC (|TE| ≤ 30 ns), and T-TSC (|TE| ≤ 35 ns or 80 ns). The diagram shows the accumulation of timing errors along the paths from the T-GM to the O-RUs. Key timing requirements include ±30...100 ns for the T-GM, ±30...95 ns for the T-BC, and ±65...130 ns for the T-TSC. The total timing error budget (TAE) is shown as 3000 ns. The diagram also indicates that the budgeting examples are based on the conservative assumption of linear accumulation between the 2 branches relevant to the TAE requirement. A note states: 'Figure is for illustrative purpose and does not provide deployment guidance (for example the number of T-BCs/T-TSCs\* in a clock chain and network topology)'. A legend defines (FR1) as NR intra-band continuous carrier aggregation in FR1 and (FR2) as NR intra-band continuous carrier aggregation in FR2 (co-located RUs only). + +**Figure 6.3.3-7: Nearest common timeTransmitter is not T-GM** + +In this LLS-C3 config, option-B model, the nearest common timeTransmitter is not T-GM for the O-RUs. Rather a T-BC is acting as common timeTransmitter to O-RUs in the front-haul network. + +Note: the time error budget allocation to support FR1 and FR2 is described in 6.3.2.2.2. Details can be found in G.8271.1 [8] Appendix XII, Examples of design options for fronthaul and clusters of base stations. + +Image: O-RAN Alliance Logo + +O-RAN.WG9.XTRP-SYN.0-R004-v06.00 + +### 6.3.3.8 Config LLS-C3 (Option C: T-GM in Mid/Back-haul) + +![Figure 6.3.3-8: T-GM in Mid/Back-haul](87d8b89e56ef93c20d7d33d42df22771_img.jpg) + +The diagram illustrates the LLS-C3 Option C configuration where the T-GM (PRTC/ePRTC) is located in the Mid/Back-haul. It shows the timing path from the PRTC/ePRTC T-GM through a nearest common T-BC, distribution sites with O-DUs and T-TSCs, intermediate T-BCs/T-TCs, and finally to remote sites with O-RUs (enhanced or regular) and T-TSCs. It details the time error budget allocations (e.g., ±100 ns, ±1100 ns, ±1500 ns, ±30...100 ns, ±30...95 ns, ±65...130 ns, ±50 ns, ±130 ns) and the resulting TAE (Time Alignment Error) requirements at the antenna (e.g., 130-260 ns, 260 ns, 3000 ns) for FR1 and FR2. + +Figure 6.3.3-8: T-GM in Mid/Back-haul + +**Figure 6.3.3-8: T-GM in Mid/Back-haul** + +In this LLS-C3 config, option-C model, the T-GM is not located in Front-haul, rather it is in either mid-haul or back-haul and drives timing towards front-haul via a T-BC. This T-BC acts as timing source for both O-DUs and O-RUs. + +Note: the time error budget allocation to support FR1 and FR2 is described in 6.3.2.2.2. Details can be found in G.8271.1 [8] Appendix XII, Examples of design options for fronthaul and clusters of base stations. + +--- + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. +38 + +#### 6.3.3.9 Config LLS-C3 (Option D: T-GM in Mid/Back-haul with T-BC chain) + +![Figure 6.3.3-9: T-GM in Mid/Backhaul with T-BC chain. This diagram illustrates the clock synchronization architecture for Option D. It shows a PRTC/ePRTC T-GM (A) connected via a PTP/SyncE path (B) to a chain of T-BCs. These T-BCs connect to distribution sites (O-DU, T-TSC) which then connect to remote sites (O-RU, T-TSC). The diagram details time error budgets (TE) and timing requirements (FR1, FR2) for different components and links. Key timing values include ±30...100 ns for the T-GM, ±1100 ns for the T-BC chain, and various TE values for O-RUs (e.g., ≤35 ns for enhanced, ≤80 ns for regular). A total TAE of 3000 ns is indicated. The diagram also notes that the budgeting examples are based on a conservative assumption of linear accumulation between the two branches relevant to the TAE requirement.](e2840c5a15026622d7b835bd3f8030df_img.jpg) + +Figure 6.3.3-9: T-GM in Mid/Backhaul with T-BC chain + +The diagram illustrates the clock synchronization architecture for Option D, showing the T-GM in the mid/backhaul connected to a chain of T-BCs, which then connect to distribution sites (O-DU, T-TSC) and remote sites (O-RU, T-TSC). + +**Timing Requirements and Budgets:** + +- PRTC/ePRTC T-GM (A):** + - PRTC A: $|TE| \leq 100$ ns + - PRTC B: $|TE| \leq 40$ ns + - ePRTC: $|TE| \leq 30$ ns +- T-BC Chain (B):** + - 1 or more T-BCs/T-TCs\* in the clock chain + - PTP/SyncE path + - Timing: $\pm 30 \dots 100$ ns + - Timing: $\pm 1100$ ns + - Timing: $\pm 1500$ ns (weak requirement) +- Remote Site (C):** + - O-RU (enhanced): $|TE| \leq 35$ ns + - O-RU (regular): $|TE| \leq 80$ ns + - T-TSC: $|TE| \leq 35$ ns + - T-TSC: $|TE| \leq 80$ ns +- Timing Requirements (E):** + - FR1: $\pm 30 \dots 95$ ns + - FR2: $\pm 65 \dots 130$ ns + - FR1: $\pm 50$ ns + - FR1: $\pm 130$ ns + - FR1: $\pm 260$ ns + - FR2: $\pm 130 \dots 260$ ns + - TAE: 3000 ns + +The budgeting examples are based on the conservative assumption of linear accumulation between the 2 branches relevant to the TAE requirement. + +leaves more holdover margin to O-RU + +(FR1): NR intra-band continuous carrier aggregation in FR1 +(FR2): NR intra-band continuous carrier aggregation in FR2 (co-located RUs only) + +Figure 6.3.3-9: T-GM in Mid/Backhaul with T-BC chain. This diagram illustrates the clock synchronization architecture for Option D. It shows a PRTC/ePRTC T-GM (A) connected via a PTP/SyncE path (B) to a chain of T-BCs. These T-BCs connect to distribution sites (O-DU, T-TSC) which then connect to remote sites (O-RU, T-TSC). The diagram details time error budgets (TE) and timing requirements (FR1, FR2) for different components and links. Key timing values include ±30...100 ns for the T-GM, ±1100 ns for the T-BC chain, and various TE values for O-RUs (e.g., ≤35 ns for enhanced, ≤80 ns for regular). A total TAE of 3000 ns is indicated. The diagram also notes that the budgeting examples are based on a conservative assumption of linear accumulation between the two branches relevant to the TAE requirement. + +**Figure 6.3.3-9: T-GM in Mid/Backhaul with T-BC chain** + +In this LLS-C3 config, option-D model, the T-GM in mid/back-haul is separated by multiple hops T-BC from front-haul network. Otherwise, front-haul network model is same for option-C and option-D + +Note: the time error budget allocation to support FR1 and FR2 is described in 6.3.2.2.2. Details can be found in G.8271.1 [8] Appendix XII, Examples of design options for fronthaul and clusters of base stations. + +# 7 Synchronization network models + +## 7.1 Factors to be considered for synchronization network design + +### 7.1.1 Source of clock and location of clock source + +The source of timing should be traceable to a recognized primary time standard such as the Coordinated Universal Time (UTC) or a global navigation satellite system (GNSS). The GNSS time offset from UTC is contained in the GNSS broadcast message. UTC is the international reference time that is computed by the Bureau International des Poids et Mesures (BIPM) from hundreds of atomic clocks maintained in national laboratories worldwide. Local representations of UTC, commonly called UTC(k) time scales, are maintained by national measurement institutes and time laboratories. GNSS uses a constellation of low-orbit satellites that covers the entire Earth's surface. + +It should be noted that for the purpose of meeting the 3GPP synchronization requirements (e.g., CPS), there is no need to recover UTC time even when UTC traceability is required. + +ePRTCs are typically distributed in the 5G Core location to protect their timing networks against regional GNSS and global GNSS outages. An ePRTC system provides in the core of the network an independent and autonomous timescale aligned with GNSS to deliver both frequency, phase and time. + +PRTCs are typically deployed in a CRAN Hub location where they distribute timing to the Boundary Clocks and O-DUs. The PRTCs can also, in an APTS configuration, receive timing from other PRTCs further down in the pre-aggregation/aggregation network. + +### 7.1.2 GM/clock source resiliency + +Timing is a mission critical service that needs to be protected by designing a highly available timing infrastructure so that no failure will cause the timing service to become unavailable. The timing infrastructure is typically dependent upon GNSS as the timing source. The latter is a single point of failure if the GNSS signal is jammed or spoofed at the PRTC-B location (e.g., Central Office, Mobile Telephone Switching Office -MTSO, etc). It is important to take appropriate measures to mitigate the risks against GNSS failure. + +Several mechanisms of resiliency can be implemented to ensure the continuity of the timing service: + +- multi-constellation GNSS to protect against one constellation failure. +- GNSS Anti-jamming/spoofing on the PRTC-B GNSS antenna (GNSS failure) +- e-PRTC-A to provide up to 14-days of holdover while maintaining up to 100 ns of accuracy. +- PRTC-B equipped with Rubidium oscillator to extend the holdover period. +- Alternate BTCA (PRTC/T-GM failure) for the timing network to automatically select an alternate PRTC-B in a different location. +- High Availability PRTC/T-GM to automatically transfer the IP address of the PRTC-B to another one in a different building. + +### 7.1.3 Holdover requirements + +The duration for which the radio should continue to operate in normal operating mode when the synchronization clock source is down. This can happen when GNSS, T-GM or network node in the synchronization path goes down. + +Major criteria to consider in determining holdover budget requirements: + +- Regulatory requirement from the government: each country/government may have different requirements as to how long the service should be up and running when there is a GNSS failure. +- Operator requirement to meet nominal operation of the service when sync goes down. +- How soon an operator can address the sync issue caused by network or GNSS failure. +- Sync redundancy model put in place. +- How often the GNSS failure may occur? This may be caused by jamming, spoofing or some neighbouring countries planned/unplanned intervention. + +One number does not fit for all. Each operator needs to carefully plan and determine the required holdover budget. Once required holdover budget is determined, it must be used to calculate overall synchronization budget from end to end (T-GM to base-station node). + +Note: CUS specification [33] does not make any explicit recommendation for holdover at Radio/base station + +Ways to mitigate the holdover condition: + +- Sync redundancy through the alternate network path in case of network node failure +- APTS in case of GNSS used at every cell site. +- Alternate flow for PTP and Sync-E in the network path +- High stratum oscillator in the end base station +- Extended holdover support at source of the sync (Ex. T-GM with extended holdover) + +### 7.1.4 Usage of packet rates + +Based on the network deployment and sync precision requirements of the clock, the PTP packet rates may need to be exercised differently. + +The factors to be considered in configuring higher packet rate: + +- High Jitter/PDV in the network +- One or more PTP unaware nodes used in the sync network. +- Network that is expected to have burst traffic. + +Different Telecom profiles and packet rate usage: + +- ITU-T G.8275.1 [1] + - Packet rate is fixed for this profile. + - 16 Sync, Delay-request and Delay-response and 8 Announce packets per second. + - User cannot change the packet rate in this profile mode of operation. Both TimeTransmitter and TimeReceiver clocks shall be able to support and function properly with this packet rate. +- ITU-T G.8275.2 [3] + - Packet rate is configurable for this profile. + - Allows up to 128 packets per second for Sync, Delay-request, Delay-Response and 8 announce packets per second. + - Packet rates plays critical role based on the clock recovery algorithm used in this profile mode of operation. + +Note-1: Packet rate can also affect the bandwidth utilization on the link hence the network. Selecting appropriate packet rate without compromising Sync performance is critical for good network operation. + +### 7.1.5 Network Topology model + +This section describes three common network topology model and deployment of sync in that network model. + +#### 7.1.5.1 Ring topology + +![Figure 7.1.5-1: Sync in ring topology. The diagram illustrates a network topology with two Access Networks and one Metro Network. The Access Networks are represented by rings of Base Stations (BS) connected to T-BC nodes. The Metro Network is a central ring connecting T-BC nodes from both Access Networks. Sync flow is indicated by colored lines: red for T-GM-1 and purple for T-GM-2. T-BC-1 and T-BC-2 in the Metro Network drive sync to T-BC-3 and T-BC-4 in the Access Networks respectively. The diagram shows a balanced sync flow model from T-BC-3 and T-BC-4 towards other nodes in the access network.](49ebbb0638a2848c657777708c427959_img.jpg) + +Figure 7.1.5-1: Sync in ring topology. The diagram illustrates a network topology with two Access Networks and one Metro Network. The Access Networks are represented by rings of Base Stations (BS) connected to T-BC nodes. The Metro Network is a central ring connecting T-BC nodes from both Access Networks. Sync flow is indicated by colored lines: red for T-GM-1 and purple for T-GM-2. T-BC-1 and T-BC-2 in the Metro Network drive sync to T-BC-3 and T-BC-4 in the Access Networks respectively. The diagram shows a balanced sync flow model from T-BC-3 and T-BC-4 towards other nodes in the access network. + +**Figure 7.1.5-1: Sync in ring topology** + +Access and Metro networks deployed in Ring topology. Every node between T-GM to Base station supports T-BC as per G.8273.2 [2]. Red line indicates sync flow from T-GM-1 and purple line indicates sync flow from T-GM-2. + +T-BC-1 and T-BC-2 in the metro network is driving the sync to access network's T-BC-3 and T-BC-4 respectively. Careful planning of sync flow within access network is critical. Sync flow can be planned two different ways – one directional flow such that all nodes in the access network source their clock in clockwise or anti-clockwise direction or balance the network nodes either side of the head node (T-BC-3 or T-BC-4). The above figure shows balanced sync flow model from T-BC-3 and T-BC-4 towards other nodes in the access network. + +Sync flow and sync redundancy in ring topology needs special consideration for multiple reasons including to avoid the timing loop, budget calculation in case of failure condition. Sync-E transient is another important aspect that needs to be considered when switching from one network node to another + +#### 7.1.5.2 Tree/Linear topology + +![Figure 7.1.5-2: Sync in Tree/Linear topology. The diagram illustrates a network topology divided into three sections: Access Network, Edge Network, and Core Network, separated by dashed vertical lines. In the Access Network, there are two leaf networks, T-BC-M and T-BC-N, each connected to a central T-BC-X node. Red arrows indicate the sync flow from the T-BC-M and T-BC-N nodes towards the T-BC-X node. In the Edge Network, there is a single T-BC node connected to the T-BC-X node. In the Core Network, there are four T-BC nodes connected in a linear sequence, with red arrows indicating the sync flow from the rightmost T-BC node towards the leftmost T-BC node. A T-GM node is shown on the far right, connected to the first T-BC node in the Core Network.](0a7e632bc7c39487ecc6d99da4250029_img.jpg) + +Figure 7.1.5-2: Sync in Tree/Linear topology. The diagram illustrates a network topology divided into three sections: Access Network, Edge Network, and Core Network, separated by dashed vertical lines. In the Access Network, there are two leaf networks, T-BC-M and T-BC-N, each connected to a central T-BC-X node. Red arrows indicate the sync flow from the T-BC-M and T-BC-N nodes towards the T-BC-X node. In the Edge Network, there is a single T-BC node connected to the T-BC-X node. In the Core Network, there are four T-BC nodes connected in a linear sequence, with red arrows indicating the sync flow from the rightmost T-BC node towards the leftmost T-BC node. A T-GM node is shown on the far right, connected to the first T-BC node in the Core Network. + +**Figure 7.1.5-2: Sync in Tree/Linear topology** + +Sync flow is from core to edge to access network in the above network topology model. Typically sync flow is unidirectional as indicated in red arrows above in case of tree/linear topology. Here G.8275.1 [1] profile-based deployment model used. This model also falls under LLS-C3 as per CUS specification [33]. + +Sync budget calculation is linear and straightforward. It is important to consider alternate paths and failure conditions for the worst-case scenario network budget calculation. Basically, number of network hops and asymmetry in the network plays a critical role in determining end-to-end sync budget calculation. + +Achieving carrier aggregation across two different leaf networks (T-BC-X to T-BC-M is one leaf network and T-BC-X to T-BC-N is another leaf network) need proper planning. O-RUs connected to T-BC-N and T-BC-M though located adjacent to each other, but their sync paths are different. + +Further, redundant sync path is critical for failover and extended sync outages. + +#### 7.1.5.3 Ladder topology + +![Diagram of a ladder topology for synchronization. It shows a 3x2 grid of nodes. The top row consists of two T-GM nodes (T-GM-1 and T-GM-2) connected to satellite icons. The middle row consists of two T-BC nodes. The bottom row consists of two T-BC nodes and one T-BC-X node. Red arrows represent sync flow from T-GM-1, and purple arrows represent sync flow from T-GM-2. The flow is unidirectional from the Core Network (top) to the Edge Network (middle) to the Access Network (bottom). The Core Network is connected to the Edge Network, which is connected to the Access Network. The T-BC-X node is connected to the two T-BC nodes in the bottom row.](0cba0a0f9c0a5f869a768b836a1969ff_img.jpg) + +Diagram of a ladder topology for synchronization. It shows a 3x2 grid of nodes. The top row consists of two T-GM nodes (T-GM-1 and T-GM-2) connected to satellite icons. The middle row consists of two T-BC nodes. The bottom row consists of two T-BC nodes and one T-BC-X node. Red arrows represent sync flow from T-GM-1, and purple arrows represent sync flow from T-GM-2. The flow is unidirectional from the Core Network (top) to the Edge Network (middle) to the Access Network (bottom). The Core Network is connected to the Edge Network, which is connected to the Access Network. The T-BC-X node is connected to the two T-BC nodes in the bottom row. + +**Figure 7.1.5-3: Sync in ladder topology** + +Redundant sync flows from two different GMs (T-GM-1 and T-GM-2) from core to edge to access network. Red arrow represents T-GM-1 sync flow and purple arrow represents T-GM-2 sync flow. Further, the sync flow is unidirectional from core to access network. + +Every node is aware of timing and support G.8273.2 [2] based T-BC clocks and exercises G.8275.1 [1] profile. All core, edge and access nodes have interconnectivity. Selection and propagation of sync flow as shown in the topology should be made carefully by configuring PTP local-priority attribute and priority attribute for Sync-E. + +In the above topology model, non-failure condition, both red sync flow and purple sync flow brought all the way to T-BC-X using proper priority attributes configuration at every hop of the network nodes. + +End to end sync budget from T-GM to O-RU radio interface must be less than 1.5usec or the required target phase budget. It is important to consider the longest path (network hops) for the budget calculation assuming failure condition. + +### 7.1.6 Number of hops + +Number of clock node hops determination depends on the following factors: + +- Target time error budget to meet (Refer section 6.3.2 for detailed description for Target time error budget and calculation) +- Longest network path of the sync network (Refer Figure 7.1.6-1) +- Type and class of clocks (BC or TC) used A, B or C +- Type of Grandmaster/PRTC used (A, B or ePRTC etc) +- Asymmetry and holdover budget requirements to meet. + +![Figure 7.1.6-1: Sync flow and hops count. The diagram shows a network topology for synchronization. A Grandmaster (GM) is connected to boundary clock R1. R1 is connected to R2 and R7. R2 is connected to R3, which is connected to R4. R4 is connected to R5, which is connected to R6. R6 is connected to R7. Each boundary clock (R1-R7) is connected to one or more Remote Units (RUs). R1 connects to R2 and R7. R2 connects to RU6. R3 connects to RU5. R4 connects to RU4. R5 connects to RU3. R6 connects to RU2. R7 connects to RU1. A red dashed line indicates the longest network path from GM to RU1: GM -> R1 -> R2 -> R3 -> R4 -> R5 -> R6 -> R7 -> RU1. A green dotted line indicates a shorter path from GM to RU1: GM -> R1 -> R7 -> RU1.](29326fa245de5c0eb8447d6d679e09e0_img.jpg) + +Figure 7.1.6-1: Sync flow and hops count. The diagram shows a network topology for synchronization. A Grandmaster (GM) is connected to boundary clock R1. R1 is connected to R2 and R7. R2 is connected to R3, which is connected to R4. R4 is connected to R5, which is connected to R6. R6 is connected to R7. Each boundary clock (R1-R7) is connected to one or more Remote Units (RUs). R1 connects to R2 and R7. R2 connects to RU6. R3 connects to RU5. R4 connects to RU4. R5 connects to RU3. R6 connects to RU2. R7 connects to RU1. A red dashed line indicates the longest network path from GM to RU1: GM -> R1 -> R2 -> R3 -> R4 -> R5 -> R6 -> R7 -> RU1. A green dotted line indicates a shorter path from GM to RU1: GM -> R1 -> R7 -> RU1. + +**Figure 7.1.6-1: Sync flow and hops count** + +The topology shown in Figure 7.1.6-1, has boundary clocks R1 to R7 and each boundary clock is serving one or more RUs or Base stations. In normal operation condition R1 recovers time from GM and drives to both R2 and R7 nodes in downstream. RU1 connected to R7 is two hops away from GM (R1 and R7) shown as green dotted line above. In this normal operational condition, the end-to-end time error budget for RU1 is just two hops away from GM. + +1 +2 +3 +4 +5 +6 +7 +8 + +If the link between R1 and R7 goes down, the same RU1 would have to recover the clock over longest chain of nodes (R1, R2, R3, R4, R5, R6 and R7) as shown in red dotted line. It is important to plan and design the network by calculating the time-error budget for the longest synchronization path rather than shortest or best path possible. Otherwise, synchronization does not work in network failure condition. + +Note1: To meet 1.5usec end to end, the longest sync chain/ number of hops determination is critical. + +Note2: Refer to G.8271.1 [8] specification for some additional description for number of hops consideration. + +### 7.1.7 Asymmetry + +What is asymmetry? + +- Difference in propagation delay between the forward and reverse path of PTP timeReceiver node from its upstream timeTransmitter node. +- Half of uncorrected asymmetry would translate to time error offset in the packet timeReceiver clock from its timeTransmitter clock. + +Types of asymmetries: + +- Static asymmetry +The (propagation) delay is constant or remains same irrespective of reboot of the node/optics or system. +- Dynamic (or semi static) asymmetry +The delay is not constant, or it would vary from reboot or reset of the node or interface or optics module. + +Note: Refer Appendix-III, IV, V of ITU-T G.8271 [7] for general details about asymmetry and how it can impact the time/sync recovery by a timeReceiver clock. + +#### 7.1.7.1 Static asymmetry types: + +1. Link/Fiber asymmetry +2. Optics asymmetry +3. Wavelength asymmetry + +##### 7.1.7.1.1 Link/Fiber asymmetry + +![Diagram illustrating Link/Fiber asymmetry between two nodes R1 and R2.](f7e6e95a44d456caf952fbdb5f0c1bcf_img.jpg) + +The diagram illustrates Link/Fiber asymmetry between two nodes, R1 and R2, represented by green circles with crosshairs. In Fig-A, a purple arrow shows the forward path from R1 to R2 with a length of 100m, while a red arrow shows the reverse path from R2 to R1 with a length of 150m, indicating a longer path. In Fig-B, two parallel blue arrows represent child-links between R1 and R2, with Child-link1 at 100m and Child-link2 at 200m. A red oval labeled 'AE/LAG bundle' is positioned between the two links, indicating a bundle of links that can cause asymmetry. + +Diagram illustrating Link/Fiber asymmetry between two nodes R1 and R2. + +**Figure 7.1.7-1: Link/Fiber asymmetry** + +The link asymmetry is defined as : $(d_{ttr} - d_{trt})/2$ + +- $d_{ttr}$ – delay from the timeTransmitter clock to timeReceiver clock. +- $d_{trt}$ – delay from the timeReceiver clock to timeTransmitter clock. + +In figure-A of Figure 7.1.7-1, Tx and Rx fiber's length differ by 50 meters between R1 (timeTransmitter clock) and R2 (timeReceiver clock) nodes. The propagation delay is 4.9 ns per meter. Effective asymmetry introduced is $50 \times 4.9 = 225$ ns. Half of asymmetry would translate to time-error offset recovered at timeReceiver node, $225/2 \Rightarrow 122.5$ ns at timeReceiver clock (R2). The topology described here is the best example for fiber asymmetry introduced by Tx and Rx fibers of the same interface. + +In figure-B of Figure 7.1.7-1, R1 and R2 connected over two child links (1 and 2) using LAG/AE bundle. If PTP packets from R1 to R2 exchanged over child-link1 and R2 to R1 exchanged over child-link2, the effective asymmetry is $(200 - 100) \times 4.9$ ns $\Rightarrow 490$ ns. Half of this asymmetry ( $490/2 \Rightarrow 245$ ns) would translate into time-error offset at timeReceiver clock. + +Note: Here the fiber length of Rx and Tx fibers of the same link/interface is same. But the fiber length of two different interfaces/links are not same and labelled as Link asymmetry. + +##### 7.1.7.1.2 Asymmetry in optics (Grey optics) + +The propagation delay inside the optics module is not zero. Especially the Tx and Rx may not be equal within a given optics. This introduces static asymmetry within the optics. This is typically seen as small value unlike the fiber asymmetry, but every nanosecond counts for high precision sync requirement. + +##### 7.1.7.1.3 Wavelength Asymmetry + +The asymmetry due to the use of different wavelength is obtained by calculating the group delay applicable to wavelengths used in the forward and in the reverse direction. + +Asymmetry $A = d_f - d_r = L * (n_r - n_f)/c$ + +- L is the distance (fiber length) +- c is the speed of light. +- $d_f$ and $d_r$ are the forward and reverse transmission delay. +- $n_r$ and $n_f$ are the group refractive indexes applicable at the wavelength used in the forward and reverse direction, respectively. + +The evaluation of the refractive indexes can be done either using known chromatic dispersion data (e.g., from the optical fiber data sheet) or, in the case that the dispersion is unknown, making a direct delay measurement at three different wavelengths (the refractive index for an arbitrary wavelength can then be derived by quadratic interpolation). + +These data can then be used to derive the group delay of a generic wavelength. In particular, in the case of an ITU-T G.652 compliant fiber, the group delay at the applicable wavelengths can be calculated making use of the Sellmeier equations as described in ITU-T G.652 standard. + +Note: For additional details refer Appendix-III in ITU-T G.8271 [7] standard and group delay specification and measurement method are specified in G.671 [40], Clause 3.2.2.25. + +#### 7.1.7.2 BiDi Optics + +Usage of BiDi optics is one option to control the fiber asymmetry. Single strand (BiDi) fiber transmission with different wavelength for Tx and Rx side – for example Tx uses 1310 nm wavelength and Rx uses 1550 nm wavelength. + +Based on the wavelength the propagation delay is different, but it can be calculated and compensated by knowing the wavelength used in Tx and Rx directions. + +Note: BiDi optics usage is not universal and not available for all possible different interface speeds. + +#### 7.1.7.3 Dynamic (or semi-static) asymmetry + +- Delay inside optics module is not fixed. +- It changes every time when the module is reset, powered down and up or sometimes when the link flaps at either end of the connection. +- Typically seen in Coherent, tuneable and OTN optics. +- This is really a tough one to address. It is fundamentally difficult to measure and hence difficult to compensate. + +It is important to understand this dynamic nature of the delay variation inside the optics module whenever these modules are used for the deployment and in turn calculating the sync budget. + +### 7.1.8 PTP packet transport + +PTP packet transport mechanisms are limited by which telecom profile used for the synchronization. Transport mechanisms for two major telecom phase profiles considered in this specification are described below: + +ITU-T G.8275.1 [1]: + +- PTP over Ethernet Multicast +- Two types of multicast frames used – Link local and forwardable multicast address. +- Link local multicast is recommended if boundary clock used at every hop. +- Mix of boundary clocks and transparent clocks deployment, forwardable multicast is recommended. + +ITU-T G.8275.2 [3]: + +- PTP over IPv4 or PTP over IPv6 unicast model +- Packet rates can be negotiated between TimeTransmitter and TimeReceiver clocks. + +Note: Usage of PTP over IPv4/IPv6 transport for full path timing support deployment is something possible but it is not covered by the ITU-T Telecom standards. + +### 7.1.9 Selection of timing profile + +In general profile selection is driven based on following criteria: + +- Target Synchronization Precision requirement + - The target precision requirement plays critical role in selection of timing profile. + - For high precise application (+/-130 nsec), ITU-T G.8275.1 [1] profile is recommended. + - For end to end 1.5usec target – it may be possible to achieve using ITU-T G.8275.2 [3] profile with proper planning and budgeting. + - Additionally, FFO limits must be considered. +- Transport mechanism used in the transport network. + - The usage of L3 versus L2 protocols in the transport nodes sometimes lead to selection of profile as G.8275.1 [1] (L2) or G.8275.2 (L3) [3]. + - The end nodes capability to support the specific timing profile will also play an important role in selecting timing for profile for the transport network nodes. +- The sync capability of the network nodes used in the transport. + - The capability of every node supporting synchronization in the transport network can be a factor in deciding the right profile. + - In green field network it is possible to use full timing support profile (G.8275.1 [1]) but in brown field network it might be possible with G.8275.2 [3] profile. +- Access to GNSS at cell site and associated CapEx and OpEx leverage + - Sync can be delivered directly or close to the base-station nodes based on the accessibility and availability of GNSS either at cell site or close to the cell-site. + - When associated cost is not a bigger concern for installation and maintenance of the high number of GNSS/T-GMs in the network. +- Network hops in the sync network + - In some cases, it may be practically limiting to achieve the targeted sync precision if too many network hops between the T-GM and O-RU (base station nodes). + - This can lead to usage of LLS-C4 option with GNSS directly connected to base-station. +- Asymmetry and control over asymmetry in the network + - If asymmetry (packet, path, link asymmetry) expected to be difficult to control, choosing right profile would play a critical role. + - For example – full timing support profile gives better control to address the network asymmetry than partial timing support profiles. +- Administrator control of the synchronization network path + - Any network hops/cloud(s) in the middle of synchronization path that does not belong to mobile operator administrative control can be risky to deploy sync. + - Example – if mobile operator selects full timing support profile, and intermediate cloud/network provider does not support timing in their network, it will break the synchronization chain. + +**Reco: This ORAN specification recommends G.8275.1 [1] full timing support profile and hence plan for the transport network to accommodate the transport mechanism described in this profile (PTP over Ethernet Multicast).** + +## 7.2 GM deployment models + +### 7.2.1 Centralized GM network model + +![Diagram of the Centralized T-GM network model. A network topology shows a Centralized Grandmaster (T-GM) connected to a ring of T-BC nodes. These T-BC nodes are further connected to a group of base station nodes. A blue callout bubble points to the T-BC nodes in the ring, stating 'Every node in Sync distribution path supports boundary (T-BC) clock'. Another blue callout bubble points to the Centralized Grandmaster, stating 'Centralized Grandmaster'. A third blue callout bubble points to the base station nodes, stating 'No GNSS required'. A large blue double-headed arrow at the bottom spans the entire network, labeled 'L2 Multicast (G.8275.1)'.](aa77942d0b7f72f6e283cd1db22f83f5_img.jpg) + +Diagram of the Centralized T-GM network model. A network topology shows a Centralized Grandmaster (T-GM) connected to a ring of T-BC nodes. These T-BC nodes are further connected to a group of base station nodes. A blue callout bubble points to the T-BC nodes in the ring, stating 'Every node in Sync distribution path supports boundary (T-BC) clock'. Another blue callout bubble points to the Centralized Grandmaster, stating 'Centralized Grandmaster'. A third blue callout bubble points to the base station nodes, stating 'No GNSS required'. A large blue double-headed arrow at the bottom spans the entire network, labeled 'L2 Multicast (G.8275.1)'. + +**Figure 7.2.1-1: Centralized T-GM network model** + +In this model, T-GM is located deep in the network (core or edge of the network). All nodes from GM to base station nodes are aware of timing and capable of supporting T-BC clock as per G.8273.2 [2] standard using full timing support profile (G.8275.1 [1]). + +This model can be deployed in a green field network or when the network hops from T-GM to end base station is not high. It is still important to consider sync redundancy for failure condition and asymmetry in the network for the purpose of reliable operation and budget calculation. + +Advantages of this deployment model: + +- Don't need to deploy and manage high number of PRTC/T-GM clocks in the network as the clock sync flows from core of the network. +- OpEx and CapEx will be low as fewer T-GMs are needed. +- No constraints on GNSS line of sight access issue at cell-sites + +Note: The cost of OpEx and CapEx comparison made with reasoning that, no need to install and manage T-GM/GNSS at each cell-site when network-based synchronization model exercised. + +### 7.2.2 Distributed GM network model + +![Figure 7.2.2-1: Distributed T-GM network model. The diagram shows a network topology where synchronization (sync) starts from the Fronthaul or Midhaul. It features T-BC (Timing Broadcast) nodes, PRTC (Precision Time Reference) nodes, and T-GM (Timing Global Master) nodes. The network is divided into two sections: 'L2 Multicast (G.8275.1)' and 'No timing support'. The T-GM node is connected to the PRTC node, which in turn connects to the T-BC nodes. The T-BC nodes are connected to the T-GM node via a ring topology. The T-GM node is also connected to the PRTC node via a ring topology. The T-GM node is connected to the PRTC node via a ring topology.](3a9820e6331d2cad1646c34d6f4cd5a0_img.jpg) + +Figure 7.2.2-1: Distributed T-GM network model. The diagram shows a network topology where synchronization (sync) starts from the Fronthaul or Midhaul. It features T-BC (Timing Broadcast) nodes, PRTC (Precision Time Reference) nodes, and T-GM (Timing Global Master) nodes. The network is divided into two sections: 'L2 Multicast (G.8275.1)' and 'No timing support'. The T-GM node is connected to the PRTC node, which in turn connects to the T-BC nodes. The T-BC nodes are connected to the T-GM node via a ring topology. The T-GM node is also connected to the PRTC node via a ring topology. The T-GM node is connected to the PRTC node via a ring topology. + +Figure 7.2.2-1: Distributed T-GM network model + +Sync starts from Front-haul or Midhaul (not in the core or backhaul). One or more T-GMs in the Fronthaul/Midhaul and delivering sync to base-stations (O-RUs) and O-DUs. From T-GM to base-station nodes full timing support profile G.8275.1 [1] is used. + +Advantages of this deployment model: + +- Fewer number of network hops +- Asymmetry in the network is better manageable. +- In a multi operator environment where Fronthaul/Midhaul, Backhaul and core networks are under different operator's control, it is easier to manage and deploy the sync requirements by mobile operator. + +### 7.2.3 Fully distributed GM/PRTC network model + +![Figure 7.2.3-1: Fully distributed T-GM/PRTC network model. The diagram shows a network topology where synchronization (sync) starts from the Fronthaul or Midhaul. It features T-GM (Timing Global Master) nodes and PRTC (Precision Time Reference) nodes. The network is divided into two sections: 'Distributed GNSS at cell sites' and 'L3 unicast (G.8275.2)'. The T-GM node is connected to the PRTC node, which in turn connects to the T-GM node via a ring topology. The T-GM node is also connected to the PRTC node via a ring topology. The T-GM node is connected to the PRTC node via a ring topology.](ff79222ec64d7dcf71ea8a4db442d335_img.jpg) + +Figure 7.2.3-1: Fully distributed T-GM/PRTC network model. The diagram shows a network topology where synchronization (sync) starts from the Fronthaul or Midhaul. It features T-GM (Timing Global Master) nodes and PRTC (Precision Time Reference) nodes. The network is divided into two sections: 'Distributed GNSS at cell sites' and 'L3 unicast (G.8275.2)'. The T-GM node is connected to the PRTC node, which in turn connects to the T-GM node via a ring topology. The T-GM node is also connected to the PRTC node via a ring topology. The T-GM node is connected to the PRTC node via a ring topology. + +Figure 7.2.3-1: Fully distributed T-GM/PRTC network model + +GNSS at base-station/radio unit is similar LLS-C4 configuration model. Using PTP over partial timing support network as backup for GNSS failure at cell site is not recommended for high precision synchronization requirements. + +Usage of PTP as backup over PTS network can be considered only for non-category A and B front-haul applications. + +### 7.2.4 Comparison of Centralized versus Distributed GM network model + +This section describes the disadvantages of distributed and network-based sync models: + +Direct GNSS to Base station: + +- Single point of failure +- Line of sight access to GNSS can be an issue if it is urban deployment. +- Jamming and/or spoofing can bring down the entire cell site down. +- No extended holdover possible as it depends on oscillator used in the base-station nodes. +- High precision sync application that needs precision between the cluster of cell-sites to be precise with less than or equal to +/-130 or +/-65 nanoseconds (ex: Carrier aggregation, NR MIMO, LTE MIMO) may not be achievable with direct GNSS based sync. +Ex1: PRTC-A it is difficult to achieve even +/-130 nsec even with enhanced Radio. +Ex2: PRTC-B – it is difficult to achieve +/-65 nsec even with enhanced Radio. +- OpEx and CapEx may be high as it depends on how many base stations deployed. +- Cost of monitoring and downtime is high. + +Network based synchronization using one or few GMs located at centralized location: + +- Every node in the network must support PTP/SyncE in case of full timing support profile deployment (exception can be O-RU) +- Asymmetry in the network can cause time/phase recovery error. +- Any node behaves incorrectly in the chain of nodes from GM to base-station, can affect entire chain of downstream nodes performance. +- KPI can be complex in wholesale environment especially with G.8275.2 [3] profile deployment case. + +#### 7.2.4.1 Different architecture choices for timing and synchronization: + +| Architecture options | Pros and Cons | +|-------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| GNSS deployed at every cell site | <ul style="list-style-type: none"> <li>• Pro: No sync support required from network</li> <li>• Con: High cost, GNSS might not always be available (jamming or spoofing)</li> </ul> | +| PTP Full Timing Support (FTS) using G.8275.1 [1] profile | <ul style="list-style-type: none"> <li>• Pro: Low cost and complexity as only few GMs needed</li> <li>• Con: Timing support needed at every node in the network chain</li> </ul> | +| Assisted Partial Timing Support (APTS) using G.8275.2 [3] profile | <ul style="list-style-type: none"> <li>• Pro: Same as GNSS deployed at every cell site with added cost and complexity for the network-based sync backup.</li> <li>• Con: High cost and complexity</li> </ul> | +| Partial Timing Support (PTS) using G.8275.2 [3] profile | <ul style="list-style-type: none"> <li>• Pro: Less cost, useful for brownfield deployment as all network nodes need to not support sync</li> <li>• Con: Will be challenging to achieve synchronization precision as it is highly dependent on the behavior of the PTP unaware network nodes.</li> </ul> | + +**Table 7-1 : Different architecture choices for sync** + +# 8 Timing Use cases and Solution Options + +This section describes the timing and synchronization solution options when applied to actual deployment use cases provided by operators. The main synchronization objective is to synchronize the radios with their serving O-DUs and maintain required timing performance (absolute between O-RU and O-DU, and relative between O-RUs). + +## 8.1 Transport network topology + +Based on the operator use cases provided in [32], more detailed transport network topology, particularly related to the Access Transport Network, is described in the following subsections. + +The icons of network transport nodes used in the diagram are defined as follows: + +- CSR: Cell Site Router, collocated with O-RUs +- HSR: Hub Site Router, aggregation router with large switching capacity +- HSR-F: Hub Site Router that distribute fronthaul traffics to O-DUs +- HSR-B/M: Hub Site Router that aggregate Backhaul or Midhaul traffics. + +### 8.1.1 C-RAN Architecture with non-collocated O-RU and O-DU + +Figure 8.1.1-1 presents a Hub-Spoke topology that is applied to the Access Transport Network for the operator use case Scenario 1 in [32], where O-RUs are located at cell site and O-DUs and O-CUs are collocated at the Hub site. The topology is described as follows: + +- The CSR aggregates the fronthaul traffics from multiple O-RUs in the same site and transports the merged traffic via high-speed ports to the Hub. +- The HSR aggregates the Fronthaul traffic from multiple sites. +- The HSR-F distributes the Fronthaul traffic received from HSR to the serving O-DUs that are paired to the corresponding O-RUs. +- O-DU and O-CU are connected internally without going through transport network, or they are implemented as an integrated unit. +- The backhaul traffic from the multiple O-CUs are aggregated by HSR-H and are transported to the aggregation Transport network. +- Connection between HSR and HSR-B is established for management and/or synchronization purposes. +- Optionally, the HSR-F may not be used and O-DUs are directly connected to HSR. + +The requirements of the timing and synchronization for architecture shown in Figure 8.1.1-1: + +- Maintain the frequency and time/phase synchronization between O-RU and its serving O-DU, within the specified Timing Alignment Error (TAE) allowance. +- Maintain the frequency and time/phase synchronization between O-RUs that are connected to the same CSR, within the specified Timing Alignment Error (TAE) allowance, per 3GPP Timing Precision requirement for different wireless applications. +- Maintain the frequency and time/phase synchronization between O-RUs that are not connected to the same CSR, within the specified Timing Alignment Error (TAE) allowance, per 3GPP Timing Precision requirement for different wireless applications. + +![Figure 8.1.1-1 C-RAN architecture with collocated O-DU and O-CU. The diagram shows a central 'Access Transport NW' block containing 'Fronthaul' and 'Midhaul' components. On the left, 'Cell sites' consist of multiple 'O-RU' blocks connected to 'CSR' blocks. On the right, a 'Hub Site' contains multiple 'O-DU' blocks, each collocated with an 'O-CU' block. These are connected to 'HSR-F' blocks. The 'HSR-F' blocks are connected to a central 'HSR' block, which is then connected to an 'HSR-B' block. The 'HSR-B' block is connected to an 'Aggregation Transport NW' block. A legend at the bottom indicates: Red line for Fronthaul, Yellow line for Midhaul, and Green line for Backhaul. Timing diagrams at the top show 'TAE (O-RU ↔ O-DU)' and 'TAE (O-RU ↔ O-RU)'.](37bbf56c82a87ab4d865bcbea1563f2a_img.jpg) + +Figure 8.1.1-1 C-RAN architecture with collocated O-DU and O-CU. The diagram shows a central 'Access Transport NW' block containing 'Fronthaul' and 'Midhaul' components. On the left, 'Cell sites' consist of multiple 'O-RU' blocks connected to 'CSR' blocks. On the right, a 'Hub Site' contains multiple 'O-DU' blocks, each collocated with an 'O-CU' block. These are connected to 'HSR-F' blocks. The 'HSR-F' blocks are connected to a central 'HSR' block, which is then connected to an 'HSR-B' block. The 'HSR-B' block is connected to an 'Aggregation Transport NW' block. A legend at the bottom indicates: Red line for Fronthaul, Yellow line for Midhaul, and Green line for Backhaul. Timing diagrams at the top show 'TAE (O-RU ↔ O-DU)' and 'TAE (O-RU ↔ O-RU)'. + +**Figure 8.1.1-1 C-RAN architecture with collocated O-DU and O-CU** + +Similarly, the Hub-Spoke architecture may apply to the operator use case Scenario 5 in [32], where O-CUs are located at a further centralized Hub site. From Fronthaul transport point of view, both Figure 8.1.1-1 and Figure 8.1.1-2 share the same architecture. Therefore, the timing solution for both is expected to be similar. + +![Figure 8.1.1-2 C-RAN architecture with split O-DU and O-CU. The diagram shows a central 'Access Transport NW' block containing 'Fronthaul' and 'Midhaul' components. On the left, 'Cell sites' consist of multiple 'O-RU' blocks connected to 'CSR' blocks. On the right, a 'Hub Site' contains multiple 'O-DU' blocks. These are connected to 'HSR-F' blocks. The 'HSR-F' blocks are connected to a central 'HSR' block, which is then connected to an 'HSR-M' block. The 'HSR-M' block is connected to 'to further Centralized O-CUs'. A legend at the bottom indicates: Red line for Fronthaul, Yellow line for Midhaul, and Green line for Backhaul. Timing diagrams at the top show 'TAE (O-RU ↔ O-DU)' and 'TAE (O-RU ↔ O-RU)'.](25c6e51598be4a0c8688aaaba554b365_img.jpg) + +Figure 8.1.1-2 C-RAN architecture with split O-DU and O-CU. The diagram shows a central 'Access Transport NW' block containing 'Fronthaul' and 'Midhaul' components. On the left, 'Cell sites' consist of multiple 'O-RU' blocks connected to 'CSR' blocks. On the right, a 'Hub Site' contains multiple 'O-DU' blocks. These are connected to 'HSR-F' blocks. The 'HSR-F' blocks are connected to a central 'HSR' block, which is then connected to an 'HSR-M' block. The 'HSR-M' block is connected to 'to further Centralized O-CUs'. A legend at the bottom indicates: Red line for Fronthaul, Yellow line for Midhaul, and Green line for Backhaul. Timing diagrams at the top show 'TAE (O-RU ↔ O-DU)' and 'TAE (O-RU ↔ O-RU)'. + +**Figure 8.1.1-2 C-RAN architecture with split O-DU and O-CU** + +### 8.1.2 C-RAN Architecture with O-RU and O-DU collocated at cell site + +This use case applies to the Hub-spoke architecture to Operator use case scenario 2, as shown in Figure 8.1.2-1, where O-DU and O-RU are collocated at the cell site, and O-CUs are centralized at the Hub site. The transport traffics flow is summarized as follows: + +- The O-RUs are connected to O-DUs via the Fronthaul link going through the CSR in the same site. +- The CSR also aggregates the Midhaul traffic from multiple O-DUs in the same site and transports the merged traffic to the Hub. +- There are two logical flows (Fronthaul, Midhaul) between O-DU and CSR as shown in the Figure 8.1.2-1. +- The HSR aggregates the Midhaul traffics from multiple cells sites. +- The backhaul traffics from the multiple O-CUs are aggregated by HSR-B and are transported to the Aggregation Transport network. +- Connection between HSR and HSR-B is established for management or synchronization purposes. + +The timing and synchronization requirement shall remain the same as described in section 8.1.1. + +![Figure 8.1.2-1 C-RAN architecture with collocated O-RU and O-DU. The diagram shows a Hub-spoke architecture. On the left, 'Cell sites' contain O-RU and O-DU blocks. O-RUs are connected to O-DUs via red lines (Fronthaul). O-DUs are connected to CSR blocks via yellow lines (Midhaul). CSRs are connected to HSR blocks via yellow lines (Midhaul). HSR blocks are connected to HSR-B blocks via green lines (Backhaul). HSR-B blocks are connected to O-CU blocks via green lines (Backhaul). O-CU blocks are connected to an 'Aggregation Transport NW' block via green lines (Backhaul). The central area is labeled 'Access Transport NW'. A legend at the bottom indicates: Red line = Fronthaul, Yellow line = Midhaul, Green line = Backhaul. Vertical arrows on the left indicate timing/synchronization: TAE (O-RU ↔ O-DU) and TAE (O-RU ↔ O-RU). A horizontal arrow in the center indicates Midhaul flow.](fc98a77eb7f88051c6bc864eaa702fab_img.jpg) + +Figure 8.1.2-1 C-RAN architecture with collocated O-RU and O-DU. The diagram shows a Hub-spoke architecture. On the left, 'Cell sites' contain O-RU and O-DU blocks. O-RUs are connected to O-DUs via red lines (Fronthaul). O-DUs are connected to CSR blocks via yellow lines (Midhaul). CSRs are connected to HSR blocks via yellow lines (Midhaul). HSR blocks are connected to HSR-B blocks via green lines (Backhaul). HSR-B blocks are connected to O-CU blocks via green lines (Backhaul). O-CU blocks are connected to an 'Aggregation Transport NW' block via green lines (Backhaul). The central area is labeled 'Access Transport NW'. A legend at the bottom indicates: Red line = Fronthaul, Yellow line = Midhaul, Green line = Backhaul. Vertical arrows on the left indicate timing/synchronization: TAE (O-RU ↔ O-DU) and TAE (O-RU ↔ O-RU). A horizontal arrow in the center indicates Midhaul flow. + +**Figure 8.1.2-1 C-RAN architecture with collocated O-RU and O-DU** + +### 8.1.3 Shared O-RU + +“Shared- O-RU” is defined by O-RAN WG4 as an O-RU that is shared between multiple O-DUs by a single operator, and/or multiple O-DUs by multiple operators. O-DUs of same or different operators shall connect to the Shared O-RU using existing CUS-Plane interface definitions and procedures, as reference to the following figure from [33], where SRO stands for Shared Resource Operator. + +![Figure 8.1.3-1 Shared O-RU diagram](5b0a5425224aa21a1a1f67fe8e204369_img.jpg) + +The diagram shows two O-DUs at the top: 'O-DU #1 (Shared O-RU Host + SRO role)' on the left and 'O-DU #2 (SRO role)' on the right. Both O-DUs have arrows pointing downwards to a central box labeled 'Shared O-RU'. The arrows are labeled 'C/U-Plane messages'. + +Figure 8.1.3-1 Shared O-RU diagram + +**Figure 8.1.3-1 Shared O-RU** + +The transport network needs to support the connectivity between a Shared O-RU to multiple O-DUs. The transport architecture may vary depending on how the transport nodes (TNs) are shared among the SROs. + +Figure 8.1.3-2 illustrates a shared transport architecture for Shared O-RU where common network nodes (CSR, HSR, etc.) are shared by the O-DUs involved in the Shared O-RU operation. The O-DUs may belong to the same SRO or different SROs. While the transport network is managed by only one SRO that is referred as Shared O-RU Host. This transport architecture only supports the use case where the O-DUs under Shared O-RU are all collocated. For simplicity, other RAN nodes not related to the Shared O-RU are not shown in this figure. + +![Figure 8.1.3-2 Common transport for Shared O-RU diagram](5308ceadc08705ca528c6b605eadfa80_img.jpg) + +The diagram illustrates a shared transport architecture. At the top, a double-headed arrow is labeled 'TAE (O-RU ↔ O-DU)'. Below this, a large orange oval represents the 'Access Transport NW Managed by Shared O-RU Host'. Inside this oval, there are two main components: 'CSR SRO 1' (Control SRO) and 'HSR SRO 1' (Host SRO), connected by a 'Fronthaul' link. To the left of the oval, there are 'Other O-RUs' and a 'Shared O-RU' (represented by a blue triangle). To the right, there are 'Other cell sites' and a 'Shared O-RU Host' containing 'O-DU 1 SRO 1' and 'O-DU 2 SRO 2'. A vertical double-headed arrow on the left is labeled 'TAE (O-RU ↔ O-RU)'. Below the diagram, there are two brackets: 'Cell sites' on the left and 'Hub Site' on the right. A legend at the bottom indicates: red line for 'Fronthaul', yellow line for 'Midhaul', and green line for 'Backhaul'. + +Figure 8.1.3-2 Common transport for Shared O-RU diagram + +**Figure 8.1.3-2 Common transport for Shared O-RU** + +Figure 8.1.3-3 shows an alternative transport architecture where transport network is separated and allowed to be managed by different SROs, for security reason or other factors. This transport architecture enables the use case where O-DUs are not collocated. + + + +## 8.2 Timing Solution Options + +This section describes options for possible timing solutions based on the network topologies defined in section 8.1. The focus is on getting O-RUs timing synchronized with their serving O-DUs and achieving required timing accuracy performance. All solutions assume G.8275.1 [1] profile therefore it is required that all the network nodes be PTP aware. + +### 8.2.1 Timing Solutions for C-RAN Architecture with non-collocated O-RU and O-DU + +The timing solution options presented in this section refer to the Access Transport Network topology as shown in Figure 8.1.1-1 or Figure 8.1.1-2. + +#### 8.2.1.1 Timing Solution by LLS-C3 configuration with GM from Fronthaul + +This timing solution option is provided based on the timing model described in section 6.3.3.7 (LLS-C3, Option B), where Telecom Grand Master (T-GM) is connected to the Fronthaul aggregator HSR and HSR distributes the timing to multiple CSRs and HSR-Fs, which will further deliver the timing to O-RUs and O-DUs. + +This solution is suitable for green field deployment where there is always Ethernet based eCPRI connection between HSR-F and O-DUs. + +![Figure 8.2.1-1: Timing solution by C3 configuration with GM from Fronthaul. The diagram illustrates the timing architecture for a C-RAN system. It shows a central 'Access Transport NW' block containing a 'PRTC/T-GM' (Telecom Grand Master) and a 'T-BC HSR' (Fronthaul aggregator). The T-GM is connected to the HSR via a yellow 'Midhaul' link. The HSR is connected to multiple 'T-BC CSR' (Common Service Routers) and 'T-BC HSR-F' (Fronthaul aggregators) via red 'Fronthaul' links. The CSRs are connected to 'O-RU T-TSC' (O-RU Timing Synchronization Clocks) via red 'Fronthaul' links. The HSR-Fs are connected to 'T-TSC O-DU+O-CU' (O-DU and O-CU Timing Synchronization Clocks) via red 'Fronthaul' links. A 'PTP flow' (Precision Time Protocol) is shown as a blue arrow from the T-GM to the HSR. The HSR-Fs are also connected to a 'HSR-B' (Backhaul aggregator) via green 'Backhaul' links. The HSR-B is connected to a 'HSR' (Backhaul aggregator) via green 'Backhaul' links. The diagram also shows 'Cell sites' and a 'Hub Site'. The 'Cell sites' are connected to the 'Hub Site' via green 'Backhaul' links. The 'Hub Site' is connected to the 'Cell sites' via green 'Backhaul' links. The diagram includes labels for 'G8275.1', 'TAE (O-RU ↔ O-DU)', and 'TAE (O-RU ↔ O-RU)'.](348010e05725652e8ff996943d81e939_img.jpg) + +Figure 8.2.1-1: Timing solution by C3 configuration with GM from Fronthaul. The diagram illustrates the timing architecture for a C-RAN system. It shows a central 'Access Transport NW' block containing a 'PRTC/T-GM' (Telecom Grand Master) and a 'T-BC HSR' (Fronthaul aggregator). The T-GM is connected to the HSR via a yellow 'Midhaul' link. The HSR is connected to multiple 'T-BC CSR' (Common Service Routers) and 'T-BC HSR-F' (Fronthaul aggregators) via red 'Fronthaul' links. The CSRs are connected to 'O-RU T-TSC' (O-RU Timing Synchronization Clocks) via red 'Fronthaul' links. The HSR-Fs are connected to 'T-TSC O-DU+O-CU' (O-DU and O-CU Timing Synchronization Clocks) via red 'Fronthaul' links. A 'PTP flow' (Precision Time Protocol) is shown as a blue arrow from the T-GM to the HSR. The HSR-Fs are also connected to a 'HSR-B' (Backhaul aggregator) via green 'Backhaul' links. The HSR-B is connected to a 'HSR' (Backhaul aggregator) via green 'Backhaul' links. The diagram also shows 'Cell sites' and a 'Hub Site'. The 'Cell sites' are connected to the 'Hub Site' via green 'Backhaul' links. The 'Hub Site' is connected to the 'Cell sites' via green 'Backhaul' links. The diagram includes labels for 'G8275.1', 'TAE (O-RU ↔ O-DU)', and 'TAE (O-RU ↔ O-RU)'. + +Figure 8.2.1-1 Timing solution by C3 configuration with GM from Fronthaul + +As result, timing accuracy performance is characterized by following the hop counts: + +- Relative timing accuracy between intra site O-RUs: + $T-TSC (O-RU) + T-BC (CSR, \text{Nearest Common BC}) + T-TSC (O-RU)$ + +- Relative timing accuracy between inter site O-RUs: + $T-TSC(O-RU) + T-BC(CSR) + T-BC(HSR, \text{Nearest Common BC}) + T-BC(CSR) + T-TSC(O-RU)$ +- Timing accuracy between an O-RU and O-DU: + $T-TSC(O-RU) + T-BC(CSR) + T-BC(HSR, \text{nearest common BC}) + T-BC(HSR-F) + T-TSC(O-DU)$ + +#### 8.2.1.2 Timing Solution by LLS-C3 configuration with T-GM from Backhaul + +This timing solution option is provided based on the timing model described in section 6.3.3.8 (LLS-C3, Option C), where the Telecom Grand Master (T-GM) is connected to the backhaul aggregator HSR-B. HSR-B serves as a first hop timing gateway to distribute the PTP flows to multiple O-DUs and HSR, which will further distribute the timing to CSR and HSR-F. + +Number of clock hops for calculating the timing accuracy: + +- Relative timing accuracy between intra-site O-RUs: + $T-TSC(O-RU) + T-BC(CSR, \text{Nearest Common BC}) + T-TSC(O-RU)$ +- Relative timing accuracy between inter-site O-RUs: + $T-TSC(O-RU) + T-BC(CSR) + T-BC(HSR, \text{Nearest Common BC}) + T-BC(CSR) + T-TSC(O-RU)$ +- Timing accuracy between an O-RU and O-DU pair: + $T-TSC(O-RU) + T-BC(CSR) + T-BC(HSR) + T-BC(HSR-B, \text{nearest common BC}) + T-TSC(O-DU)$ + +![Figure 8.2.1-2: Timing solution by LLS-C3 configuration with T-GM from Backhaul. The diagram illustrates the network architecture for timing distribution. On the left, 'Cell sites' contain O-RUs and T-TSC blocks. These are connected via 'Fronthaul' (red lines) to 'T-BC CSR' blocks within the 'Access Transport NW'. The 'Access Transport NW' also contains 'T-BC HSR' and 'HSR-F' blocks. On the right, the 'Hub Site' contains 'T-TSC O-DU+O-CU' blocks, 'T-BC HSR-B', and a 'PRTC/T-GM' block. The 'PRTC/T-GM' is connected to 'T-BC HSR-B' via 'Backhaul' (green lines). 'T-BC HSR-B' is connected to 'T-BC HSR' and 'HSR-F' via 'Midhaul' (yellow lines). 'T-BC HSR' and 'HSR-F' are connected to 'T-TSC O-DU+O-CU' blocks via 'Fronthaul' (red lines). The diagram also shows 'PTP flow' (blue arrows) and various timing accuracy metrics: 'TAE (O-RU ↔ O-RU)' for intra-site, 'TAE (O-RU ↔ O-DU)' for inter-site, and 'G8275.1' for the overall system. A legend at the bottom indicates: Red line for Fronthaul, Yellow line for Midhaul, and Green line for Backhaul.](d7451736e3f386b5ec78a088e7ffd356_img.jpg) + +Figure 8.2.1-2: Timing solution by LLS-C3 configuration with T-GM from Backhaul. The diagram illustrates the network architecture for timing distribution. On the left, 'Cell sites' contain O-RUs and T-TSC blocks. These are connected via 'Fronthaul' (red lines) to 'T-BC CSR' blocks within the 'Access Transport NW'. The 'Access Transport NW' also contains 'T-BC HSR' and 'HSR-F' blocks. On the right, the 'Hub Site' contains 'T-TSC O-DU+O-CU' blocks, 'T-BC HSR-B', and a 'PRTC/T-GM' block. The 'PRTC/T-GM' is connected to 'T-BC HSR-B' via 'Backhaul' (green lines). 'T-BC HSR-B' is connected to 'T-BC HSR' and 'HSR-F' via 'Midhaul' (yellow lines). 'T-BC HSR' and 'HSR-F' are connected to 'T-TSC O-DU+O-CU' blocks via 'Fronthaul' (red lines). The diagram also shows 'PTP flow' (blue arrows) and various timing accuracy metrics: 'TAE (O-RU ↔ O-RU)' for intra-site, 'TAE (O-RU ↔ O-DU)' for inter-site, and 'G8275.1' for the overall system. A legend at the bottom indicates: Red line for Fronthaul, Yellow line for Midhaul, and Green line for Backhaul. + +**Figure 8.2.1-2 Timing solution by LLS-C3 configuration with T-GM from Backhaul** + +The benefit of this solution is support for some non-O-RAN compliant use cases (such as Scenario 4 described in [32]), where there is no direct Ethernet link between HSR-F and O-DUs. For example, Figure 8.2.1-3 + +illustrates timing solution to support legacy RRH and BBU with RoE as Fronthaul transport. In this case, HSR-F needs to receive sync from HSR in order to get synchronized with BBU for RoE transmission. The Timing chain for RoE: + +![Figure 8.2.1-3 Timing solution to support RoE. The diagram shows a network architecture with Cell sites and a Hub Site. Cell sites include RRHs connected to O-RUs (T-TSC) and FHGs (T-TSC CSR). The Hub Site includes HSR-F, HSR-B, T-TSC O-DU+O-CU, T-TSC BBU, and PRTC/T-GM. The Access Transport NW connects these components. Timing flows are shown: Fronthaul (red), Midhaul (yellow), and Backhaul (green). A timing chain formula is provided: T-TSC(CSR) + T-BC(HSR) + T-BC (HSR-B, nearest common BC) + T-TSC(BBU). The total timing error is G8275.1. TAE (O-RU ↔ O-DU) and TAE (O-RU ↔ O-RU) are also indicated.](0114530ebfa96a80f6157ea2f5cdaac7_img.jpg) + +$T-TSC(CSR) + T-BC(HSR) + T-BC (HSR-B, \text{nearest common BC}) + T-TSC(BBU)$ + +**G8275.1** + +TAE (O-RU ↔ O-DU) + +TAE (O-RU ↔ O-RU) + +Access Transport NW + +Fronthaul + +PTP flow + +Cell sites + +Hub Site + +— Fronthaul — Midhaul — Backhaul + +Figure 8.2.1-3 Timing solution to support RoE. The diagram shows a network architecture with Cell sites and a Hub Site. Cell sites include RRHs connected to O-RUs (T-TSC) and FHGs (T-TSC CSR). The Hub Site includes HSR-F, HSR-B, T-TSC O-DU+O-CU, T-TSC BBU, and PRTC/T-GM. The Access Transport NW connects these components. Timing flows are shown: Fronthaul (red), Midhaul (yellow), and Backhaul (green). A timing chain formula is provided: T-TSC(CSR) + T-BC(HSR) + T-BC (HSR-B, nearest common BC) + T-TSC(BBU). The total timing error is G8275.1. TAE (O-RU ↔ O-DU) and TAE (O-RU ↔ O-RU) are also indicated. + +**Figure 8.2.1-3 Timing solution to support RoE** + +#### 8.2.1.3 Timing solution – LLS-C3 configuration with Ring topology in Midhaul and Backhaul – O-DU connected to HSR and sync starts from Backhaul + +In reference to ring topology model given in section 7.1.5.1, the Figure 8.2.1-4 presents a case where both Midhaul and Backhaul networks are ring and synchronization flows from T-GM located in the backhaul ring. + +T-GM-A and T-GM-B are two GMs located in backhaul ring (R1) providing sync redundancy. The backhaul boundary clock nodes - BH-1, BH-2 and BH-3 are configured to source the clock from T-GM-A whereas BH-4, BH-5 and BH-6 are configured using A-BTCA algorithm and PTP attributes described in section 6.2.6, to source the clock from T-GM-B. + +In midhaul ring (R2), the HSR-1 and HSR-2 sources sync from T-GM-A through BH-3 node whereas the HSR-3 sources sync from T-GM-B through BH4 node. O-DUs are connected to HSR nodes. + +In fronthaul, CSR-1 and CSR-2 sources sync from T-GM-A through HSR-1 and HSR-2 respectively whereas CSR-3 sources sync from T-GM-B through HSR-3. + +The Blue and Green arrows represent active sync path from T-GM-A and T-GM-B and the Grey arrow represents the standby/redundant flow in case of sync failure. + +Note: The number of hops in the synchronization chain is constrained by the type of clocks (class-A, Class-B or Class-C) used, presence of Sync-E or enhanced Sync-E and the capability of O-RU (oscillator, filter bandwidth – refer section Annex H of [33] and section 6.3 of this specification) + +![Figure 8.2.1-4: Ring topology with sync from Backhaul and O-DU connected to HSR. The diagram shows a network topology with three main rings: Backhaul (R1), Midhaul (R2), and Fronthaul. Cell sites are connected to the Fronthaul ring via O-RU and T-TSC blocks. The Backhaul ring (R1) includes T-BC BH-1 through T-BC BH-6, connected to PRTC/T-GM A and B. The Midhaul ring (R2) includes T-BC HSR-1 through T-BC HSR-3, connected to T-TSC O-DU blocks. T-BC CSR1 through T-BC CSR3 are connected to the Fronthaul ring. Active PTP (green double-headed arrows) and Standby PTP (grey single-headed arrows) are shown between various nodes. A legend indicates: Active PTP (green double-headed arrow), Standby PTP (grey single-headed arrow), R1 - Backhaul Ring, R2 - Midhaul Ring. A color-coded legend at the bottom shows: Fronthaul (red line), Midhaul (yellow line), Backhaul (green line).](dcdf49fc76af6f2fadce660829b217c5_img.jpg) + +Figure 8.2.1-4: Ring topology with sync from Backhaul and O-DU connected to HSR. The diagram shows a network topology with three main rings: Backhaul (R1), Midhaul (R2), and Fronthaul. Cell sites are connected to the Fronthaul ring via O-RU and T-TSC blocks. The Backhaul ring (R1) includes T-BC BH-1 through T-BC BH-6, connected to PRTC/T-GM A and B. The Midhaul ring (R2) includes T-BC HSR-1 through T-BC HSR-3, connected to T-TSC O-DU blocks. T-BC CSR1 through T-BC CSR3 are connected to the Fronthaul ring. Active PTP (green double-headed arrows) and Standby PTP (grey single-headed arrows) are shown between various nodes. A legend indicates: Active PTP (green double-headed arrow), Standby PTP (grey single-headed arrow), R1 - Backhaul Ring, R2 - Midhaul Ring. A color-coded legend at the bottom shows: Fronthaul (red line), Midhaul (yellow line), Backhaul (green line). + +**Figure 8.2.1-4 Ring topology with sync from Backhaul and O-DU connected to HSR** + +The timing error budget calculation described in section 6.3.2, including error introduced by Sync-E transient shall be considered to meet the end-to-end synchronization requirements. + +Note: Clock distribution in Xhaul networks is recommended (depending on the topology) to be uni-directional from upstream to downstream (Backhaul to Midhaul and Midhaul to Fronthaul). When a clock flow changes from downstream to upstream (also known as Clock backflow), caused by a failure in the network or node, it is difficult to predict the failed over clock flow, and it may cause unexpected deterioration of clock accuracy. + +In the topology described in Figure 8.2.1-4, the PTP flow between HSR-2 and CSR-2 may get reversed when the link between HSR-1 and HSR-2 goes down and HSR-1, HSR-2 and CSR-2 PTP ports are configured with default PTP attributes. This is basically a reverse flow of synchronization, and this can be prevented by configuring the ports in HSR-1/2/3 connected to CSRs at cell sites as “TimeTransmitterOnly” PTP port as per ITU-T G.8275.1 [1] + +#### 8.2.1.4 Timing solution – LLS-C3 configuration with Ring topology in Midhaul and Backhaul – O-DU connected to CSR and sync starts from Backhaul + +![Figure 8.2.1-5: Ring topology with sync from backhaul network and O-DU connected to CSR. The diagram shows a network architecture with three main rings: Backhaul (R1), Midhaul (R2), and Fronthaul. Cell sites are connected to the Fronthaul ring via O-RU and T-TSC nodes. The Fronthaul ring connects to the Midhaul ring via T-BC CSR nodes. The Midhaul ring connects to the Backhaul ring via T-BC HSR nodes. The Backhaul ring connects to the Core via T-BC BH nodes. The O-DU is connected to the CSR node. The diagram also shows Active PTP (Active Precision Time Protocol) and Standby PTP connections. The legend indicates: Active PTP (green double arrow), Standby PTP (grey double arrow), R1 - Backhaul Ring, R2 - Midhaul Ring, Fronthaul (red line), Midhaul (yellow line), and Backhaul (green line).](eea7084621962792e8b0aec8307b0db5_img.jpg) + +Figure 8.2.1-5: Ring topology with sync from backhaul network and O-DU connected to CSR. The diagram shows a network architecture with three main rings: Backhaul (R1), Midhaul (R2), and Fronthaul. Cell sites are connected to the Fronthaul ring via O-RU and T-TSC nodes. The Fronthaul ring connects to the Midhaul ring via T-BC CSR nodes. The Midhaul ring connects to the Backhaul ring via T-BC HSR nodes. The Backhaul ring connects to the Core via T-BC BH nodes. The O-DU is connected to the CSR node. The diagram also shows Active PTP (Active Precision Time Protocol) and Standby PTP connections. The legend indicates: Active PTP (green double arrow), Standby PTP (grey double arrow), R1 - Backhaul Ring, R2 - Midhaul Ring, Fronthaul (red line), Midhaul (yellow line), and Backhaul (green line). + +**Figure 8.2.1-5 Ring topology with sync from backhaul network and O-DU connected to CSR** + +The topology described in Figure 8.2.1-5 differs from Figure 8.2.1-4 by O-DU location. In the topology described in Figure 8.2.1-5, the O-DU is connected directly to CSR node. This topology model guarantees both O-DU and O-RU sources the sync from same upstream node, CSR in this case. + +#### 8.2.1.5 Timing solution – LLS-C3 configuration with Ring topology in Midhaul and Backhaul – O-DU connected to HSR and sync starts from midhaul network + +![Figure 8.2.1-6: Ring topology with sync from midhaul and O-DU connected to HSR node. The diagram shows a network architecture with three main rings: Backhaul (R1), Midhaul (R2), and Fronthaul. Cell sites are connected to the Fronthaul ring via O-RU and T-TSC blocks. The Fronthaul ring connects to the Midhaul ring via T-BC CSR blocks (CSR1, CSR2, CSR3). The Midhaul ring contains T-BC HSR blocks (HSR-1, HSR-2, HSR-3) and T-TSC O-DU blocks. The Midhaul ring connects to the Backhaul ring via T-BC BH blocks (BH-3, BH-4). Synchronization is provided by PRTC/T-GM A and B blocks in the Midhaul ring. Active PTP (Active Precision Time Protocol) is shown as green double-headed arrows, and Standby PTP is shown as grey double-headed arrows. The legend indicates: R1 - Backhaul Ring, R2 - Midhaul Ring. The color coding for the rings is: Fronthaul (red), Midhaul (yellow), and Backhaul (green).](cd32bcf38cccc256ee0681857ea26445_img.jpg) + +Figure 8.2.1-6: Ring topology with sync from midhaul and O-DU connected to HSR node. The diagram shows a network architecture with three main rings: Backhaul (R1), Midhaul (R2), and Fronthaul. Cell sites are connected to the Fronthaul ring via O-RU and T-TSC blocks. The Fronthaul ring connects to the Midhaul ring via T-BC CSR blocks (CSR1, CSR2, CSR3). The Midhaul ring contains T-BC HSR blocks (HSR-1, HSR-2, HSR-3) and T-TSC O-DU blocks. The Midhaul ring connects to the Backhaul ring via T-BC BH blocks (BH-3, BH-4). Synchronization is provided by PRTC/T-GM A and B blocks in the Midhaul ring. Active PTP (Active Precision Time Protocol) is shown as green double-headed arrows, and Standby PTP is shown as grey double-headed arrows. The legend indicates: R1 - Backhaul Ring, R2 - Midhaul Ring. The color coding for the rings is: Fronthaul (red), Midhaul (yellow), and Backhaul (green). + +Figure 8.2.1-6 Ring topology with sync from midhaul and O-DU connected to HSR node + +In order to avoid longer synchronization network hops, the topology described in Figure 8.2.1-6 presents a model where T-GM-A and B located in the midhaul. There are no synchronization requirements in the backhaul for this topology model. + +#### 8.2.1.6 Timing solution – LLS-C3 configuration with Ring topology in Midhaul and Backhaul – O-DU connected to CSR and sync starts from midhaul network + +![Figure 8.2.1-7 Ring topology with sync from midhaul and O-DU connected to CSR node. The diagram shows a network topology with three main rings: Backhaul (R1), Midhaul (R2), and Fronthaul. Cell sites are connected to the Fronthaul ring. O-DUs are connected to CSR nodes (T-BC CSR1, T-BC CSR2, T-BC CSR3). The Midhaul ring (R2) contains nodes T-BC HSR-1, T-BC HSR-2, and T-BC HSR-3. The Backhaul ring (R1) contains nodes T-BC BH-1 and T-BC BH-2. PRTC/T-GM A and PRTC/T-GM B are also shown. Active PTP is indicated by green double-headed arrows, and Standby PTP by grey single-headed arrows. The legend identifies the rings: R1 - Backhaul Ring, R2 - Midhaul Ring. The legend also identifies the link types: Fronthaul (red), Midhaul (yellow), and Backhaul (green).](3d31bd6a021f9c3e899c746f35d4f5d9_img.jpg) + +Figure 8.2.1-7 Ring topology with sync from midhaul and O-DU connected to CSR node. The diagram shows a network topology with three main rings: Backhaul (R1), Midhaul (R2), and Fronthaul. Cell sites are connected to the Fronthaul ring. O-DUs are connected to CSR nodes (T-BC CSR1, T-BC CSR2, T-BC CSR3). The Midhaul ring (R2) contains nodes T-BC HSR-1, T-BC HSR-2, and T-BC HSR-3. The Backhaul ring (R1) contains nodes T-BC BH-1 and T-BC BH-2. PRTC/T-GM A and PRTC/T-GM B are also shown. Active PTP is indicated by green double-headed arrows, and Standby PTP by grey single-headed arrows. The legend identifies the rings: R1 - Backhaul Ring, R2 - Midhaul Ring. The legend also identifies the link types: Fronthaul (red), Midhaul (yellow), and Backhaul (green). + +Cell sites + +**Figure 8.2.1-7 Ring topology with sync from midhaul and O-DU connected to CSR node** + +In this topology presented in Figure 8.2.1-7, the O-DUs are connected to CSR node directly and synchronization starts from midhaul network (R2). The backhaul network (R1) is not aware of synchronization in this model. + +#### 8.2.1.7 Timing Solution with LLS-C2 configuration with single O-DU + +Following the LLS-C2 option B model given in section 6.3.3.5, Figure 8.2.1-8 presents a simple C2 timing configuration where one O-DU has the capacity serving multiple O-RUs at multiples sites via a HSR that aggregates the Fronthaul traffic and therefore serves as nearest common BC. A PRTC/T-GM directly feeds the PTP timing to the O-DU, or optionally it can be integrated with the O-DU. + +The benefit of this C2 timing solution is O-DU is in PTP path to all the O-RUs, which gives the O-DU better control for optimizing the radio performance. + +The timing accuracy is characterized by following the hop counts: + +- Relative timing accuracy between intra cell-site O-RUs: + $T-TSC (O-RU) + T-BC (CSR, \text{Nearest Common BC}) + T-TSC (O-RU)$ +- Relative timing accuracy between inter cell-site O-RUs: + $T-TSC (O-RU) + T-BC (CSR) + T-BC (HSR, \text{Nearest Common BC}) + T-BC (CSR) + T-TSC (O-RU)$ +- Timing accuracy between O-RU and O-DU: + $T-TSC (O-RU) + T-BC (CSR) + T-BC (HSR) + T-BC (O-DU)$ + +![Figure 8.2.1-8 Timing solution for LLS-C2 configuration: single O-DU. The diagram illustrates the timing architecture for a single O-DU configuration. It shows a central 'Access Transport NW' block containing 'T-BC CSR' and 'T-BC HSR' components. On the left, 'Cell sites' are represented by 'O-RU T-TSC' blocks. On the right, the 'Hub Site' contains 'T-BC O-DU' and 'PRTC/T-GM' blocks. Red arrows indicate 'Fronthaul' connections from O-RUs to T-BC CSRs. Green arrows indicate 'Backhaul' connections from T-BC CSRs to T-BC HSR. A yellow arrow indicates 'Midhaul' connection from T-BC HSR to T-BC O-DU. Blue arrows show 'PTP flow' paths. Vertical double-headed arrows on the left represent 'TAE (O-RU ↔ O-RU)' and 'TAE (O-RU ↔ O-DU)'. A horizontal double-headed arrow at the top represents 'G8275.1' and 'TAE (O-RU ↔ O-DU)'.](e1a5cbe67a66e41b8e21a98cf27e73c5_img.jpg) + +Figure 8.2.1-8 Timing solution for LLS-C2 configuration: single O-DU. The diagram illustrates the timing architecture for a single O-DU configuration. It shows a central 'Access Transport NW' block containing 'T-BC CSR' and 'T-BC HSR' components. On the left, 'Cell sites' are represented by 'O-RU T-TSC' blocks. On the right, the 'Hub Site' contains 'T-BC O-DU' and 'PRTC/T-GM' blocks. Red arrows indicate 'Fronthaul' connections from O-RUs to T-BC CSRs. Green arrows indicate 'Backhaul' connections from T-BC CSRs to T-BC HSR. A yellow arrow indicates 'Midhaul' connection from T-BC HSR to T-BC O-DU. Blue arrows show 'PTP flow' paths. Vertical double-headed arrows on the left represent 'TAE (O-RU ↔ O-RU)' and 'TAE (O-RU ↔ O-DU)'. A horizontal double-headed arrow at the top represents 'G8275.1' and 'TAE (O-RU ↔ O-DU)'. + +Figure 8.2.1-8 Timing solution for LLS-C2 configuration: single O-DU + +#### 8.2.1.8 Timing Solution for LLS-C2 configuration with multiple O-DUs + +For the transport network with larger scale that need to facilitate multiple O-DUs, the LLS-C2 timing solution is implemented as shown in Figure 8.2.1-9, where a single HSR router is used for traffic aggregation and providing switching flexibility among O-DUs. The T-GM distributes the PTP timing to the O-DUs directly. + +Since the HSR is only allowed to lock to a single timing source by the definition of the G8275.1 profile, only one O-DU (denoted as the primary O-DU) is active in the PTP path. This primary O-DU may control the timing of multiple cell sites that are directly connected to the HSR. The rest of O-DUs are effectively acts as backup time source in this use case scenario. + +It is evident that the Primary O-DU and HSR-F that provide the PTP path are single point of failure. To improve the redundancy, the PTP functions in all O-DUs are enabled to deliver multiple PTP flows simultaneously to next hop node, even though only one of them is used by HSR. In the event of any failure, the A-BTCA function at next hop is responsible to detect the failover and automatically select and switch over to alternative PTP flow. + +The timing accuracy performance: + +- Relative timing accuracy between intra site O-RUs: + $T-TSC (O-RU) + T-BC (CSR, \text{Nearest Common BC}) + T-TSC (O-RU)$ +- Relative timing accuracy between inter site O-RUs: + $T-TSC (O-RU) + T-BC (CSR) + T-BC (HSR, \text{Nearest Common BC}) + T-BC (CSR) + T-TSC (O-RU)$ +- Timing accuracy between an O-RU and O-DU: +Primary O-DU + +$T-TSC(O-RU) + T-BC(CSR) + T-BC(HSR) + T-BC(HSR-F) + T-BC(O-DU)$ + +Other O-DUs + +$T-TSC(O-RU) + T-BC(CSR) + T-BC(HSR) + T-BC(HSR-F) + T-BC(O-DU) + T-BC(HSR-B) + T-TSC(O-DU)$ + +![Figure 8.2.1-9 Timing solution for LLS-C2 configuration: multiple O-DUs. The diagram illustrates the timing architecture for a C-RAN system with multiple O-DUs. It shows the Access Transport Network (ATN) connecting Cell sites and a Hub Site. Cell sites contain O-RU T-TSC blocks connected to T-BC CSR blocks. The Hub Site contains T-BC HSR-F blocks connected to T-BC O-DU blocks. A Primary T-BC O-DU is connected to a PRTC/T-GM block. The diagram shows the flow of timing signals (PTP flow) and the distribution of timing error budget (TAE) across the network. The legend indicates Fronthaul (red line), Midhaul (yellow line with circles), and Backhaul (green line).](ad2a50562ce5ff545595b22576dbc04f_img.jpg) + +Figure 8.2.1-9 Timing solution for LLS-C2 configuration: multiple O-DUs. The diagram illustrates the timing architecture for a C-RAN system with multiple O-DUs. It shows the Access Transport Network (ATN) connecting Cell sites and a Hub Site. Cell sites contain O-RU T-TSC blocks connected to T-BC CSR blocks. The Hub Site contains T-BC HSR-F blocks connected to T-BC O-DU blocks. A Primary T-BC O-DU is connected to a PRTC/T-GM block. The diagram shows the flow of timing signals (PTP flow) and the distribution of timing error budget (TAE) across the network. The legend indicates Fronthaul (red line), Midhaul (yellow line with circles), and Backhaul (green line). + +Figure 8.2.1-9 Timing solution for LLS-C2 configuration: multiple O-DUs + +### 8.2.2 Timing Solutions for C-RAN Architecture with O-RU and O-DU collocated at cell site + +The timing solution options presented in this section are based on the Access Transport Network topology as shown in Figure 8.1.2-1. + +#### 8.2.2.1 Timing Solution for LLS-C3 configuration with T-GM from Midhaul + +As shown in Figure 8.2.2-1, the Telecom Grand Master is connected to HSR that distributes the timing to CSRs of all connected sites. O-RUs and O-DUs then get their timing from CSR. + +Hops for calculating the timing error budget: + +- Relative timing accuracy between intra-site O-RUs: + $T-TSC(O-RU) + T-BC(CSR, \text{Nearest Common BC}) + T-TSC(O-RU)$ +- Relative timing accuracy between inter-site O-RUs: + $T-TSC(O-RU) + T-BC(CSR) + T-BC(HSR, \text{Nearest Common BC}) + T-BC(CSR) + T-TSC(O-RU)$ + +- Timing accuracy between a O-RU and O-DU pair: + $T-TSC(O-RU) + T-BC(CSR, \text{nearest common BC}) + T-TSC(O-DU)$ + +![Figure 8.2.2-1: Timing Solution by C3 configuration with GM from Midhaul. This diagram illustrates the timing architecture for a C3 configuration where the Global Timing (GM) is derived from the Midhaul. On the left, 'Cell sites' contain O-RU and T-TSC blocks. These are connected via red 'Fronthaul' lines to T-TSC and O-DU blocks. These O-DU blocks connect to T-BC CSR blocks within the 'Access Transport NW' (orange oval). A 'Midhaul' connection (yellow arrow) links a T-BC CSR block to a T-BC HSR block. A 'PRTC/T-GM' block is connected to the T-BC HSR block. On the right, the 'Hub Site' contains O-CU blocks connected to the T-BC HSR block via yellow 'Midhaul' lines. The T-BC HSR block is also connected to an HSR-B block, which is part of the 'Aggregation Transport NW'. Green 'Backhaul' lines connect the HSR-B block to the O-CU blocks. A legend at the bottom identifies the line types: red for Fronthaul, yellow for Midhaul, and green for Backhaul. Vertical arrows on the left indicate timing relationships: TAE (O-RU ↔ O-DU) and TAE (O-RU ↔ O-RU). A horizontal arrow at the top indicates a timing range of G8275.1.](29e052df350e2bf2356355b204ccf791_img.jpg) + +Figure 8.2.2-1: Timing Solution by C3 configuration with GM from Midhaul. This diagram illustrates the timing architecture for a C3 configuration where the Global Timing (GM) is derived from the Midhaul. On the left, 'Cell sites' contain O-RU and T-TSC blocks. These are connected via red 'Fronthaul' lines to T-TSC and O-DU blocks. These O-DU blocks connect to T-BC CSR blocks within the 'Access Transport NW' (orange oval). A 'Midhaul' connection (yellow arrow) links a T-BC CSR block to a T-BC HSR block. A 'PRTC/T-GM' block is connected to the T-BC HSR block. On the right, the 'Hub Site' contains O-CU blocks connected to the T-BC HSR block via yellow 'Midhaul' lines. The T-BC HSR block is also connected to an HSR-B block, which is part of the 'Aggregation Transport NW'. Green 'Backhaul' lines connect the HSR-B block to the O-CU blocks. A legend at the bottom identifies the line types: red for Fronthaul, yellow for Midhaul, and green for Backhaul. Vertical arrows on the left indicate timing relationships: TAE (O-RU ↔ O-DU) and TAE (O-RU ↔ O-RU). A horizontal arrow at the top indicates a timing range of G8275.1. + +Figure 8.2.2-1 Timing Solution by C3 configuration with GM from Midhaul + +#### 8.2.2.2 Timing Solution for LLS-C3 configuration with GM from Fronthaul + +In this case, every cell site will have its own local T-GM and timing accuracy performance is the same as section 8.2.2.1. + +![Figure 8.2.2-2: Timing Solution by C3 configuration with GM from Fronthaul. This diagram illustrates the timing architecture for a C3 configuration where the Global Timing (GM) is derived from the Fronthaul. The structure is similar to Figure 8.2.2-1, but with a key difference: each 'Cell site' now contains its own 'PRTC/T-GM' block. The 'PRTC/T-GM' block in each cell site is connected to the T-BC CSR block via a red 'Fronthaul' line. The 'Access Transport NW' (orange oval) contains the T-BC CSR and T-BC HSR blocks, connected by a yellow 'Midhaul' arrow. The 'Hub Site' on the right contains O-CU blocks connected to the T-BC HSR block via yellow 'Midhaul' lines. The T-BC HSR block is connected to an HSR-B block, which is part of the 'Aggregation Transport NW'. Green 'Backhaul' lines connect the HSR-B block to the O-CU blocks. A legend at the bottom identifies the line types: red for Fronthaul, yellow for Midhaul, and green for Backhaul. Vertical arrows on the left indicate timing relationships: TAE (O-RU ↔ O-DU) and TAE (O-RU ↔ O-RU). A horizontal arrow at the top indicates a timing range of G8275.1.](df6f62a8b28f5e648da3d4b09db03f5b_img.jpg) + +Figure 8.2.2-2: Timing Solution by C3 configuration with GM from Fronthaul. This diagram illustrates the timing architecture for a C3 configuration where the Global Timing (GM) is derived from the Fronthaul. The structure is similar to Figure 8.2.2-1, but with a key difference: each 'Cell site' now contains its own 'PRTC/T-GM' block. The 'PRTC/T-GM' block in each cell site is connected to the T-BC CSR block via a red 'Fronthaul' line. The 'Access Transport NW' (orange oval) contains the T-BC CSR and T-BC HSR blocks, connected by a yellow 'Midhaul' arrow. The 'Hub Site' on the right contains O-CU blocks connected to the T-BC HSR block via yellow 'Midhaul' lines. The T-BC HSR block is connected to an HSR-B block, which is part of the 'Aggregation Transport NW'. Green 'Backhaul' lines connect the HSR-B block to the O-CU blocks. A legend at the bottom identifies the line types: red for Fronthaul, yellow for Midhaul, and green for Backhaul. Vertical arrows on the left indicate timing relationships: TAE (O-RU ↔ O-DU) and TAE (O-RU ↔ O-RU). A horizontal arrow at the top indicates a timing range of G8275.1. + +Figure 8.2.2-2 Timing Solution by C3 configuration with GM from Fronthaul + +### 8.2.3 Timing Solutions for Shared O-RU + +This section focuses on the LLS-C3 model for Shared O-RU since O-DUs are not in the timing path towards the O-RU (i.e., O-DUs operates as T-TSC) is considered more appropriate for multiple SRO operation. + +Figure 8.2.3-1 describes the timing solution for commonly shared transport architecture (corresponding to Figure 8.1.3-2), which generally operates similar to a regular O-RU with LLS-C3 timing architecture. + +![Figure 8.2.3-1 Timing Solution for Shared O-RU with common transport. This diagram illustrates a network architecture where multiple cell sites share a common transport network managed by a shared O-RU host. On the left, 'Cell sites' include a 'Shared O-RU' and 'Other O-RUs'. These connect via 'Fronthaul' (red lines) to an 'Access Transport NW' block. This block contains 'CSR SRO 1' and 'HSR SRO 1'. The 'Access Transport NW' is managed by the 'Shared O-RU Host'. A 'PTP flow' (blue arrow) is shown between the Shared O-RU and CSR SRO 1. The 'Access Transport NW' connects via 'Midhaul' (yellow lines) to a 'Hub Site'. The Hub Site contains 'PRTC/T-GM' and 'O-DU 1 SRO 1' and 'O-DU 2 SRO 2'. The Hub Site is managed by the 'Shared O-RU Host'. The diagram shows timing paths for G8275.1 and TAE (O-RU ↔ O-DU).](d4c2caf85db78e3ac9b783d785e73f13_img.jpg) + +Figure 8.2.3-1 Timing Solution for Shared O-RU with common transport. This diagram illustrates a network architecture where multiple cell sites share a common transport network managed by a shared O-RU host. On the left, 'Cell sites' include a 'Shared O-RU' and 'Other O-RUs'. These connect via 'Fronthaul' (red lines) to an 'Access Transport NW' block. This block contains 'CSR SRO 1' and 'HSR SRO 1'. The 'Access Transport NW' is managed by the 'Shared O-RU Host'. A 'PTP flow' (blue arrow) is shown between the Shared O-RU and CSR SRO 1. The 'Access Transport NW' connects via 'Midhaul' (yellow lines) to a 'Hub Site'. The Hub Site contains 'PRTC/T-GM' and 'O-DU 1 SRO 1' and 'O-DU 2 SRO 2'. The Hub Site is managed by the 'Shared O-RU Host'. The diagram shows timing paths for G8275.1 and TAE (O-RU ↔ O-DU). + +**Figure 8.2.3-1 Timing Solution for Shared O-RU with common transport** + +When the transport is separated (Figure 8.1.3-3), the timing solution for Shared O-RU takes the form of Figure 8.2.3-2, where second timing source (T-GM 2) is introduced to support O-DU 2 for SRO 2, which may be located at different hub site. This T-GM 2 is managed by SRO2 in its own transport network therefore will serve as the primary timing source for O-DU 2. The requirement for the second T-GM is that it has to source the same time source (such as the GNSS tracking to the same UTC as the T-GM 1 of SRO 1). + +![Figure 8.2.3-2 Timing Solution for Shared O-RU with separated transport. This diagram illustrates a network architecture where the transport is separated. On the left, 'Cell sites' include a 'Shared O-RU' and 'Other O-RUs'. These connect via 'Fronthaul' (red lines) to an 'Access Transport NW' block. This block contains 'CSR SRO 1' and 'HSR 1 SRO 1'. The 'Access Transport NW' is managed by the 'Shared O-RU Host'. A 'PTP flow' (blue arrow) is shown between the Shared O-RU and CSR SRO 1. The 'Access Transport NW' connects via 'Midhaul' (yellow lines) to 'Hub Sites'. The Hub Sites contain 'PRTC/T-GM 1 SRO 1', 'HSR 1 SRO 1', 'HSR 2 SRO 2', and 'PRTC/T-GM 2 SRO 2'. The Hub Sites are managed by the 'Shared O-RU Host'. The diagram shows timing paths for G8275.1 and TAE (O-RU ↔ O-DU).](6b7733e0bff69a686ba519d1af83fede_img.jpg) + +Figure 8.2.3-2 Timing Solution for Shared O-RU with separated transport. This diagram illustrates a network architecture where the transport is separated. On the left, 'Cell sites' include a 'Shared O-RU' and 'Other O-RUs'. These connect via 'Fronthaul' (red lines) to an 'Access Transport NW' block. This block contains 'CSR SRO 1' and 'HSR 1 SRO 1'. The 'Access Transport NW' is managed by the 'Shared O-RU Host'. A 'PTP flow' (blue arrow) is shown between the Shared O-RU and CSR SRO 1. The 'Access Transport NW' connects via 'Midhaul' (yellow lines) to 'Hub Sites'. The Hub Sites contain 'PRTC/T-GM 1 SRO 1', 'HSR 1 SRO 1', 'HSR 2 SRO 2', and 'PRTC/T-GM 2 SRO 2'. The Hub Sites are managed by the 'Shared O-RU Host'. The diagram shows timing paths for G8275.1 and TAE (O-RU ↔ O-DU). + +**Figure 8.2.3-2 Timing Solution for Shared O-RU with separated transport** + +It is optional to use the T-GM 2 as backup timing source to the O-RU via HSR2 to CSR. + +### 8.2.4 Timing/Synchronization Redundancy & Resiliency + +A reliable timing/sync solution is specifically important for C-RAN deployment due to its high impact when timing/sync of a hub site fails. Redundancy and Resiliency solutions will provide most efficient ways of improving the timing/sync reliability by avoiding single point failure. + +#### 8.2.4.1 Redundant Timing Solutions + +In case of PRTC or T-GM failure, the Assisted Partial Timing Support described in section 6.2.3 can be used as the solution to achieve geo-redundancy. + +Figure 8.2.4-1 illustrates a redundant timing solution by following configurations + +- Provide backup timing for use case described in Figure 8.2.1-2 +- APTS functions (IWF and T-BC-P) are integrated in the external Grand Master +- The backup timing source is received from the T-GM at central network side, via a Partial Timing Supported Network + +![Figure 8.2.4-1: Backup Timing Solution for backhaul based C3 configuration, IWF integrated in T-GM. The diagram shows a timing architecture where a primary GNSS/PRTC source is crossed out (indicated by a red X). Its function is integrated into a T-GM/T-BC-P/IWF block. This block connects to a T-BC HSR and a T-BC HSR-B via FTS PTP (blue arrows). The T-BC HSR-B is connected to O-DUs. A backhaul connection (green line) links the T-BC HSR-B to an Aggregation/Core NW cloud, which contains a Partial Timing Support Network. This network is connected to a NW T-GM, which in turn is connected to a secondary GNSS/PRTC source. APTS PTP (orange arrows) show the backup timing path from the NW T-GM through the Partial Timing Support Network to the T-BC HSR-B.](0eb1dcffbadfe89387f807a7f5631131_img.jpg) + +Figure 8.2.4-1: Backup Timing Solution for backhaul based C3 configuration, IWF integrated in T-GM. The diagram shows a timing architecture where a primary GNSS/PRTC source is crossed out (indicated by a red X). Its function is integrated into a T-GM/T-BC-P/IWF block. This block connects to a T-BC HSR and a T-BC HSR-B via FTS PTP (blue arrows). The T-BC HSR-B is connected to O-DUs. A backhaul connection (green line) links the T-BC HSR-B to an Aggregation/Core NW cloud, which contains a Partial Timing Support Network. This network is connected to a NW T-GM, which in turn is connected to a secondary GNSS/PRTC source. APTS PTP (orange arrows) show the backup timing path from the NW T-GM through the Partial Timing Support Network to the T-BC HSR-B. + +**Figure 8.2.4-1 Backup Timing Solution for backhaul based C3 configuration, IWF integrated in T-GM** + +Optionally, the APTS support function can be integrated in HSR-B, as shown in Figure 8.2.4-2. + +![Figure 8.2.4-2: Backup Timing Solution for backhaul, C3 configuration, IWF integrated in HSR-B. This diagram is similar to Figure 8.2.4-1, but the APTS PTP (orange arrows) path is different. The backup timing is received from the NW T-GM through the Partial Timing Support Network in the Aggregation/Core NW cloud, then directly to the T-BC HSR-B block. The T-GM/T-BC-P/IWF block remains integrated in the T-GM, and the primary GNSS/PRTC source is still crossed out.](9f68c73ead642293dcd0b9c1061dce85_img.jpg) + +Figure 8.2.4-2: Backup Timing Solution for backhaul, C3 configuration, IWF integrated in HSR-B. This diagram is similar to Figure 8.2.4-1, but the APTS PTP (orange arrows) path is different. The backup timing is received from the NW T-GM through the Partial Timing Support Network in the Aggregation/Core NW cloud, then directly to the T-BC HSR-B block. The T-GM/T-BC-P/IWF block remains integrated in the T-GM, and the primary GNSS/PRTC source is still crossed out. + +**Figure 8.2.4-2 Backup Timing Solution for backhaul, C3 configuration, IWF integrated in HSR-B** + +Similarly, for LLS-C3 timing configuration where T-GM is applied at Fronthaul network (as shown in Figure 8.2.1-1), the backup timing solution is described in Figure 8.2.4-3. Optionally T-BC-P and IWF can be integrated into HSR. + +![Figure 8.2.4-3 Backup Timing Solution for Fronthaul based on C3 configuration, IWF integrated in T-GM. The diagram shows a timing architecture. At the top left, a yellow box labeled 'GNSS/PRTC' has a red 'X' over it, indicating it is not used. Below it is a yellow box labeled 'T-GM' and 'T-BC-P/IWF'. A blue arrow points from this box to a green box labeled 'T-BC HSR'. This green box has blue arrows pointing to 'HSRs' and 'HSR-F/O-DUs'. A grey arrow points from the 'T-GM' box to another green box labeled 'T-BC HSR-B'. This box is connected to a cloud labeled 'Aggregation/Core NW' via a line labeled 'backhaul'. The cloud contains a box labeled 'Partial Timing Support Network'. To the right of the cloud is another yellow box labeled 'GNSS/PRTC' and 'NW T-GM'. A grey arrow points from this box to the cloud. A red double-headed arrow is shown between the 'T-GM' box and the 'Aggregation/Core NW' cloud.](3ff6a9d95c9431ba2c2b49b6add50319_img.jpg) + +Figure 8.2.4-3 Backup Timing Solution for Fronthaul based on C3 configuration, IWF integrated in T-GM. The diagram shows a timing architecture. At the top left, a yellow box labeled 'GNSS/PRTC' has a red 'X' over it, indicating it is not used. Below it is a yellow box labeled 'T-GM' and 'T-BC-P/IWF'. A blue arrow points from this box to a green box labeled 'T-BC HSR'. This green box has blue arrows pointing to 'HSRs' and 'HSR-F/O-DUs'. A grey arrow points from the 'T-GM' box to another green box labeled 'T-BC HSR-B'. This box is connected to a cloud labeled 'Aggregation/Core NW' via a line labeled 'backhaul'. The cloud contains a box labeled 'Partial Timing Support Network'. To the right of the cloud is another yellow box labeled 'GNSS/PRTC' and 'NW T-GM'. A grey arrow points from this box to the cloud. A red double-headed arrow is shown between the 'T-GM' box and the 'Aggregation/Core NW' cloud. + +**Figure 8.2.4-3 Backup Timing Solution for Fronthaul based on C3 configuration, IWF integrated in T-GM** + +#### 8.2.4.2 General Resiliency Solutions + +The following resiliency implementation is recommended for a reliable timing/sync architecture: + +- Dual timing sources (T-GMs) +- Duplicated TNEs that may have large scale of impact the (HSRs, HSR-Bs, etc.) +- Dual connectivity/Dual homing (T-GM to TNE, TNE to TNE, TNE to O-DU) +- Enable standby PTP in all resilience devices. + +Note: During synchronization network failover condition, with certain combination of clock types (specifically with large number of hops), Sync-E transient and/or PTP re-arrangement may cause short-term degradation in performance and that might affect the operation of the radio interface (particularly, the frequency stability requirement on the radio interface might be impacted). + +##### 8.2.4.2.1 PTP Resiliency + +As part of resiliency network model, there will be multiple PTP paths available. Only one of the paths for a timeReceiver node will be selected for primary operation of the G8275.1 profile and rest are considered as the standby that are used only if failure occurs. This is illustrated in the figure below, where the active PTP (blue arrow) indicates the PTP that is sent to the node and it is used to synchronize its clock while the standby PTP (grey arrow) indicates the PTP that is sent to the node but it is not taken as source of synchronization until a failover occurs. + +![Figure 8.2.4-4 Resiliency solution diagram. The diagram shows a transition from a single path to a redundant path. On the left, a green box 'T-BC HSR' is connected to an orange box 'PRTC/T-GM A'. A large arrow labeled 'Resiliency' points to the right. On the right, a more complex topology is shown: 'T-BC HSR A' and 'T-BC HSR B' (green boxes) are connected to 'PRTC/T-GM A' and 'PRTC/T-GM B' (orange boxes). Bidirectional arrows labeled 'A-BTCA' connect the HSR nodes to the PRTC/T-GM nodes. A legend at the bottom indicates that a blue arrow represents 'Active PTP' and a grey arrow represents 'Standby PTP'.](bd4db3fa40eb4c07497b779ad4fa28e2_img.jpg) + +Figure 8.2.4-4 Resiliency solution diagram. The diagram shows a transition from a single path to a redundant path. On the left, a green box 'T-BC HSR' is connected to an orange box 'PRTC/T-GM A'. A large arrow labeled 'Resiliency' points to the right. On the right, a more complex topology is shown: 'T-BC HSR A' and 'T-BC HSR B' (green boxes) are connected to 'PRTC/T-GM A' and 'PRTC/T-GM B' (orange boxes). Bidirectional arrows labeled 'A-BTCA' connect the HSR nodes to the PRTC/T-GM nodes. A legend at the bottom indicates that a blue arrow represents 'Active PTP' and a grey arrow represents 'Standby PTP'. + +**Figure 8.2.4-4 Resiliency solution** + +Selection of the primary (active) PTP path or switchover to alternate path when failure occurs is controlled by A-BTCA algorithm that will be driven by the different PTP attributes configured on those nodes: + +- Local priority settings to facilitate pre-determined PTP path. +- Timing performance (clock accuracy or clock variance) based switchover. + +The goal of the resiliency design is to minimize the disruption whenever PTP path changes: + +- Maintain the same time source (T-GM) as much as possible. +- Maintain same timing topology (number of nodes/clocks, number of hops) as much as possible. +- Minimize changes in the PTP path. +- Sync-E sourced from the same time source as the PTP source (T-GM) is recommended. + +##### 8.2.4.2.2 Resiliency under LAG + +In case of multiple links between two nodes configured, such as LAG bundle, PTP can be enabled on more than one links. In the event when one link fails, A-BTCA can automatically switchover to another link under the LAG bundle. Local priority can be configured such that the A-BTCA picks the link from the same LAG bundle than the link connected to another node, as shown in Figure 8.2.4-5. (The circle indicates LAG bundle in the figure) + +![Figure 8.2.4-5: PTP resiliency configuration under LAG. The diagram shows three TNEs (TNE 1, TNE 2, TNE 3) connected to an A-BTCA block. TNE 1 and TNE 2 are connected via a LAG bundle. TNE 3 is connected via a dashed line. Arrows indicate PTP paths: Priority 0 (Active PTP) from TNE 1 to A-BTCA, Priority 1 (Standby PTP) from TNE 1 to A-BTCA, and Priority 2 (Standby PTP) from TNE 2 to A-BTCA. A legend shows a blue arrow for Active PTP and a grey arrow for Standby PTP.](945cc2f80e0c02d57b5c0e86ca3eb10d_img.jpg) + +Figure 8.2.4-5: PTP resiliency configuration under LAG. The diagram shows three TNEs (TNE 1, TNE 2, TNE 3) connected to an A-BTCA block. TNE 1 and TNE 2 are connected via a LAG bundle. TNE 3 is connected via a dashed line. Arrows indicate PTP paths: Priority 0 (Active PTP) from TNE 1 to A-BTCA, Priority 1 (Standby PTP) from TNE 1 to A-BTCA, and Priority 2 (Standby PTP) from TNE 2 to A-BTCA. A legend shows a blue arrow for Active PTP and a grey arrow for Standby PTP. + +Figure 8.2.4-5 PTP resiliency configuration under LAG + +##### 8.2.4.2.3 Sync-E Configuration + +As part of G8275.1 profile, Sync-E shall also be enabled along the path from the timing source (T-GM) to the end application node (T-TSC). The Sync-E is hop-by-hop service, therefore each node along the path shall be configured. + +Sync-E source selection or switching is not controlled by PTP A-BTCA, rather it can be achieved via configuration, based on separate priority and clock quality level. Hence the Sync-E path may choose different links from the PTP when failover occurs. Note that dual/redundancy timing source case model, it is preferred that the Sync-E and PTP always driven from the same PRTC/T-GM, even though they may take different network paths or optionally Sync-E can be on the same path as the PTP so that both can switch simultaneously. + +![Figure 8.2.4-6: SyncE at different path from PTP. The diagram shows a timing source (T-TSC) connected to a PTP block (PTP, CSR, EEC). The PTP block is connected to HSR A and HSR B via A-BTCA. HSR A and HSR B are connected to a PRTC/T-GM block. Arrows indicate PTP paths (blue) and SyncE paths (red). A legend shows a blue arrow for PTP and a red arrow for SyncE.](4d67603d15f0fbab39083a7be3fd51f7_img.jpg) + +Figure 8.2.4-6: SyncE at different path from PTP. The diagram shows a timing source (T-TSC) connected to a PTP block (PTP, CSR, EEC). The PTP block is connected to HSR A and HSR B via A-BTCA. HSR A and HSR B are connected to a PRTC/T-GM block. Arrows indicate PTP paths (blue) and SyncE paths (red). A legend shows a blue arrow for PTP and a red arrow for SyncE. + +Figure 8.2.4-6 SyncE at different path from PTP + +#### 8.2.4.3 Resiliency use cases + +Some resiliency examples based on section 8.2 are described in the following subsections. + +##### 8.2.4.3.1 Resiliency Timing Solution by LLS-C3 configuration with GM from Fronthaul + +Corresponding to the timing solution described in 8.2.1.1, the resiliency solution is illustrated in Figure 8.2.4-7. + +![Figure 8.2.4-7: Resiliency Timing Solution for LLS-C3 configuration with GM from Fronthaul. The diagram illustrates a network architecture with Cell sites and a Hub Site. Cell sites include O-RU/T-TSC blocks connected to T-BC/CSR blocks. The Hub Site includes T-BC/HSR blocks (HSR A, HSR B, HSR-F 1, HSR-F m), PRTC/T-GM blocks (A, B), and T-TSC/O-DU blocks (O-DU1, O-DU2, O-DUn-1, O-DUn). Active PTP paths are shown in red, and Standby PTP paths are shown in grey. A-BTCA (Active Backup Timing Change) arrows indicate the flow of timing information. The legend identifies Fronthaul (red), Midhaul (yellow), and Backhaul (green) links.](9bc778a2ea84bc8cd5323da8ee5e92dc_img.jpg) + +Figure 8.2.4-7: Resiliency Timing Solution for LLS-C3 configuration with GM from Fronthaul. The diagram illustrates a network architecture with Cell sites and a Hub Site. Cell sites include O-RU/T-TSC blocks connected to T-BC/CSR blocks. The Hub Site includes T-BC/HSR blocks (HSR A, HSR B, HSR-F 1, HSR-F m), PRTC/T-GM blocks (A, B), and T-TSC/O-DU blocks (O-DU1, O-DU2, O-DUn-1, O-DUn). Active PTP paths are shown in red, and Standby PTP paths are shown in grey. A-BTCA (Active Backup Timing Change) arrows indicate the flow of timing information. The legend identifies Fronthaul (red), Midhaul (yellow), and Backhaul (green) links. + +**Figure 8.2.4-7 Resiliency Timing Solution for LLS-C3 configuration with GM from Fronthaul** + +The local priority at each TNE is configured in such a way that the active PTP path as follows: + +O-RU timing: T-GM A $\rightarrow$ HSR A $\rightarrow$ CSRs $\rightarrow$ O-RUs + +O-DU timing: T-GM A $\rightarrow$ HSR A $\rightarrow$ HSR-Fs $\rightarrow$ O-DUs + +PTP flow change in failover cases (Figure 8.2.4-8): + +- Failure case 1: Link from HSR A to one of the CSRs fails (e.g. HSR A $\rightarrow$ CSR 1 fails) +CSR1 switches to Standby PTP from HSR B (HSR B $\rightarrow$ CSR 1, PTP changes from Standby to Active) +- Failure case 2: HSR A fails or link connecting HSR A and T-GM A fails +(HSR B $\rightarrow$ CSRs) and (HSR B $\rightarrow$ HSR-Fs) PTP changes from Standby to Active +- Failure case 3: T-GM A fails or link connecting T-GM A to HSR A and HSR B fails +(T-GM B $\rightarrow$ HSR A) and (T-GM B $\rightarrow$ HSR B) PTP changes from Standby to Active +- Failure case 4: link connecting HSR A to one of HSR-Fs (e.g. HSR A $\rightarrow$ HSR-F 1 fails) + +(HSR B → HSR-F 1) PTP changes from Standby to Active + +Figure 8.2.4-8 illustrates these PTP flow changes when failover occurs. + +Note that whenever the PTP path changes, there is possible impact on the timing performance. For example, the first case in the above when the link from HSR A to a CSR fails, the relative timing accuracy between inter site O-RUs will degrade because the nearest common BC is extended to T-GM A. One option to maintain the same timing performance is to choose to use HSR B for all cell sites. + +Note: Clock distribution in the Xhaul networks is recommended (depending on the topology) to be uni-directional from upstream to downstream (Backhaul to Midhaul and Midhaul to Fronthaul). When a clock flow changes from downstream to upstream (also known as Clock backflow), caused by a failure in a link or node, it is very difficult to predict the failed over clock flow, and it may cause unexpected deterioration of clock accuracy. + +In order to prevent PTP backflow from occurring, it is recommended to configure the PTP ports in HSR-A/B connected to the CSRs in the cellsites as "TimeTransmitterOnly" ports as per ITU-T G.8275.1 [1] + +![Diagram illustrating PTP flow changes during a failure in a hub site. The diagram shows Cell sites on the left and a Hub Site on the right. Cell sites contain O-RU/T-TSC blocks connected to T-BC/CSR blocks. The Hub Site contains T-BC/HSR blocks (A, B, F 1, F m) and T-TSC/O-DU blocks. Active PTP paths are shown with blue arrows, and standby paths with grey arrows. A red circle with a slash indicates a failed link between T-BC/CSR 1 and T-BC/HSR A. A legend at the bottom identifies the path types.](5d3afe99b49e130a2a52d6e4d9c75c8c_img.jpg) + +**Failure case 1** + +← Active PTP Paths +← Standby PTP Paths + +Cell sites +Hub Site + +Diagram illustrating PTP flow changes during a failure in a hub site. The diagram shows Cell sites on the left and a Hub Site on the right. Cell sites contain O-RU/T-TSC blocks connected to T-BC/CSR blocks. The Hub Site contains T-BC/HSR blocks (A, B, F 1, F m) and T-TSC/O-DU blocks. Active PTP paths are shown with blue arrows, and standby paths with grey arrows. A red circle with a slash indicates a failed link between T-BC/CSR 1 and T-BC/HSR A. A legend at the bottom identifies the path types. + +![Network diagram for Failure case 2 showing Cell sites and Hub Site components with active and standby PTP paths.](818f345f65a7936a9eed4c1aaf47c145_img.jpg) + +### Failure case 2 + +The diagram illustrates a network topology for Failure case 2. On the left, multiple **Cell sites** are shown, each containing an **O-RU** and a **T-TSC** block. These are connected to a row of **T-BC** blocks labeled **CSR 1** through **CSR n**. On the right, the **Hub Site** contains a row of **T-BC** blocks labeled **HSR-F 1** through **HSR-F m**, followed by a row of **T-TSC** blocks labeled **O-DU1** through **O-DUn**. A central **HSR-B** block is also present. In the center, there are **PRTC/T-GM** blocks for **A** and **B**, and a **T-BC HSR B** block. A **T-BC HSR A** block is marked with a red 'X', indicating a failure. Red arrows represent **Active PTP Paths**, and grey arrows represent **Standby PTP Paths**. The connections are categorized by color: red for **Fronthaul**, orange for **Midhaul**, and green for **Backhaul**. + +Network diagram for Failure case 2 showing Cell sites and Hub Site components with active and standby PTP paths. + +1 +2 +3 + +![Network diagram for Failure case 3 showing Cell sites and Hub Site components with active and standby PTP paths.](f33a7199e288b03df124b0d99a69e025_img.jpg) + +### Failure case 3 + +The diagram illustrates a network topology for Failure case 3. The structure is similar to Failure case 2, with **Cell sites** on the left and **Hub Site** components on the right. In this case, the **PRTC/T-GM A** block in the center is marked with a red 'X', indicating a failure. The **T-BC HSR A** block is active. Red arrows represent **Active PTP Paths**, and grey arrows represent **Standby PTP Paths**. The connections are categorized by color: red for **Fronthaul**, orange for **Midhaul**, and green for **Backhaul**. + +Network diagram for Failure case 3 showing Cell sites and Hub Site components with active and standby PTP paths. + +4 + +![Network diagram showing PTP path changes in Failure case 4. The diagram is divided into 'Cell sites' and 'Hub Site'. Cell sites include O-RU/T-TSC and T-BC/CSR blocks. The Hub Site includes T-BC/HSR blocks, PRTC/T-GM blocks, and T-TSC/O-DU blocks. A red 'X' marks a failed connection between T-BC HSR A and T-BC HSR-F 1. Active PTP paths are shown in blue, and standby paths in grey. A legend at the bottom identifies Fronthaul (red), Midhaul (yellow), and Backhaul (green) links.](770d0073e4a83322143a899b75821dee_img.jpg) + +**Failure case 4** + +←→ Active PTP Paths +←→ Standby PTP Paths + +— Fronthaul    — Midhaul    — Backhaul + +Network diagram showing PTP path changes in Failure case 4. The diagram is divided into 'Cell sites' and 'Hub Site'. Cell sites include O-RU/T-TSC and T-BC/CSR blocks. The Hub Site includes T-BC/HSR blocks, PRTC/T-GM blocks, and T-TSC/O-DU blocks. A red 'X' marks a failed connection between T-BC HSR A and T-BC HSR-F 1. Active PTP paths are shown in blue, and standby paths in grey. A legend at the bottom identifies Fronthaul (red), Midhaul (yellow), and Backhaul (green) links. + +**Figure 8.2.4-8 PTP Path Changes in Failover Cases** + +1 +2 +3 +4 +5 +6 + +##### 8.2.4.3.2 Resiliency Timing Solution for LLS-C3 configuration with T-GM from Backhaul + +Figure 8.2.4-9 illustrates the primary and standby PTP design based on the use case defined in 8.2.1.2 + +![Figure 8.2.4-9: Resiliency for LLS-C3 configuration with GM from Backhaul. The diagram shows a network architecture with Cell sites and a Hub Site. Cell sites include O-RU/T-TSC and T-BC/CSR. The Hub Site includes T-BC/HSR A, T-BC/HSR B, HSR-F 1, HSR-F m, T-TSC/O-DU+CU 1, T-TSC/O-DU+CU 2, ..., T-TSC/O-DU+CU n-1, T-TSC/O-DU+CU n, PRTC/T-GM A, PRTC/T-GM B, T-BC/HSR-B A, and T-BC/HSR-B B. Active PTP Paths are shown in red, and Standby PTP Paths are shown in grey. The legend indicates: Red line = Fronthaul, Orange line = Midhaul, Green line = Backhaul. Arrows indicate the direction of PTP paths.](960a216f56d8e9564aaa801a4c37c641_img.jpg) + +Figure 8.2.4-9: Resiliency for LLS-C3 configuration with GM from Backhaul. The diagram shows a network architecture with Cell sites and a Hub Site. Cell sites include O-RU/T-TSC and T-BC/CSR. The Hub Site includes T-BC/HSR A, T-BC/HSR B, HSR-F 1, HSR-F m, T-TSC/O-DU+CU 1, T-TSC/O-DU+CU 2, ..., T-TSC/O-DU+CU n-1, T-TSC/O-DU+CU n, PRTC/T-GM A, PRTC/T-GM B, T-BC/HSR-B A, and T-BC/HSR-B B. Active PTP Paths are shown in red, and Standby PTP Paths are shown in grey. The legend indicates: Red line = Fronthaul, Orange line = Midhaul, Green line = Backhaul. Arrows indicate the direction of PTP paths. + +**Figure 8.2.4-9 Resiliency for LLS-C3 configuration with GM from Backhaul** + +The local priority at each TNE is configured in such a way that the active PTP path is configured as follows: + +Primary: + +- O-RU timing: T-GM A $\rightarrow$ HSR-B A $\rightarrow$ HSR A $\rightarrow$ CSRs $\rightarrow$ O-RUs +- O-DU timing: T-GM A $\rightarrow$ HSR-B A $\rightarrow$ O-DU+CU + +Failover cases: + +- T-GM A or link from T-GM A to HSR-B A fail +(T-GM B $\rightarrow$ HSR B A) PTP path changes from Standby to Active +- HSR-B A or link from HSR-B A to HSR A fail +(T-GM A $\rightarrow$ HSR-B B $\rightarrow$ HSR B) PTP paths change from Standby to Active +(HSR-B $\rightarrow$ CSR 1) PTP path changes from Standby to Active +... +(HSR-B $\rightarrow$ CSR n) PTP path changes from Standby to Active +- HSR A fails +(HSR-B $\rightarrow$ CSR 1) PTP path changes from Standby to Active +... +(HSR-B $\rightarrow$ CSR n) PTP path changes from Standby to Active +- link from HSR A to one of CSRs fails (e.g., HSR A $\rightarrow$ CSR 1 fails) +(HSR B $\rightarrow$ CSR 1) PTP path changes from Standby to Active + +##### 8.2.4.3.3 Resiliency Timing Solution for LLS-C2 configuration with multiple O-DUs + +Figure 8.2.4-10 illustrates the primary and standby PTP design based on the use case defined in 8.2.1.8. + +![Figure 8.2.4-10 Resiliency for LLS-C2 configuration with Multiple O-DUs. The diagram illustrates a network architecture for resiliency. On the left, 'Cell sites' contain O-RU T-TSC blocks connected to T-BC CSRs. In the center, 'Hub Site' contains T-BC HSR blocks (A, B, F 1, F m). On the right, there are T-TSC O-DU+CU blocks (1, 2, n-1, n) and HSR-B blocks (A, B). Connections are color-coded: red for Fronthaul, orange for Midhaul, and green for Backhaul. Blue arrows represent 'Active PTP' paths, and grey arrows represent 'Standby PTP' paths. A-BTCA labels indicate specific connection points. The diagram shows how the active path can shift from one HSR block to another in response to failures.](e3c121c6944a62c0af09157f7045bd6e_img.jpg) + +Figure 8.2.4-10 Resiliency for LLS-C2 configuration with Multiple O-DUs. The diagram illustrates a network architecture for resiliency. On the left, 'Cell sites' contain O-RU T-TSC blocks connected to T-BC CSRs. In the center, 'Hub Site' contains T-BC HSR blocks (A, B, F 1, F m). On the right, there are T-TSC O-DU+CU blocks (1, 2, n-1, n) and HSR-B blocks (A, B). Connections are color-coded: red for Fronthaul, orange for Midhaul, and green for Backhaul. Blue arrows represent 'Active PTP' paths, and grey arrows represent 'Standby PTP' paths. A-BTCA labels indicate specific connection points. The diagram shows how the active path can shift from one HSR block to another in response to failures. + +**Figure 8.2.4-10 Resiliency for LLS-C2 configuration with Multiple O-DUs** + +The local priority at each TNE is configured in such a way that the active PTP path is configured as follows: + +Primary case: + +T-GM A → HSR-B A → O-DU+CU<sub>s</sub> 1 → HSR-F A → HSR A → CSRs → O-RUs + +Failover cases: + +- T-GM A or link from T-GM A to HSR-B A fail +(T-GM B → HSR-B A) PTP path changes from Standby to Active +- O-DU+CU or link from O-DU to HSR-F fails (e.g., O-DU+CU → HSR-F 1 fails) +(O-DU+CU 2 → HSR-F 1) PTP path changes from Standby to Active +- HSR-F 1 or link from HSR-F 1 to HSR-A fails +(HSR-F 2 → HSR A) PTP path changes from Standby to Active +- HSR A fails +(HSR B → CSR 1) PTP path changes from Standby to Active +- ... +- (HSR B → CSR n) PTP path changes from Standby to Active +- link from HSR A to one of CSR fails (e.g. HSR A → CSR 1 fails) +(HSR B → CSR 1) PTP path changes from Standby to Active + +##### 8.2.4.3.4 Resiliency Timing Solution for LLS-C4 configuration with frequency backup from T-GM. + +Figure 8.2.4-11 illustrates primary (GNSS/PRTC) and backup (Frequency) synchronization path for LLS-C4 topology configuration. + +![Figure 8.2.4-11: Resiliency Timing Solution for LLS-C4 configuration with frequency backup from T-GM. The diagram shows a central green box labeled 'CSR' (Central Switching Router) connected via red lines (Fronthaul) to four blue boxes labeled 'O-RU PRTC/T-TSC' and 'PRTC/T-TSC O-DU1', 'PRTC/T-TSC O-DU2'. A yellow box labeled 'PRTC/T-GM' is connected to the CSR. A bracket below the diagram indicates 'Cell sites (DU, RU co-located)'. A legend at the bottom shows a red line for 'Fronthaul' and a black line with a circle for 'Standby PTP(Frequency)'.](41e338caecceb0a1ebe5afe8ae6f9bfb_img.jpg) + +Figure 8.2.4-11: Resiliency Timing Solution for LLS-C4 configuration with frequency backup from T-GM. The diagram shows a central green box labeled 'CSR' (Central Switching Router) connected via red lines (Fronthaul) to four blue boxes labeled 'O-RU PRTC/T-TSC' and 'PRTC/T-TSC O-DU1', 'PRTC/T-TSC O-DU2'. A yellow box labeled 'PRTC/T-GM' is connected to the CSR. A bracket below the diagram indicates 'Cell sites (DU, RU co-located)'. A legend at the bottom shows a red line for 'Fronthaul' and a black line with a circle for 'Standby PTP(Frequency)'. + +**Figure 8.2.4-11 Resiliency for LLS-C4 configuration with Frequency backup from T-GM.** + +Primary sync source: O-RU/O-DU will be synced using the GNSS Receiver. + +Backup sync source: T-GM sourcing the clock through PTP unaware node (CSR) towards O-DU and O-RU. Upon any GPS fault in O-RU(s)/O-DU(s), unit(s) moves to holdover with the frequency recovered using PTP and continues to be in holdover. + +##### 8.2.4.3.5 Resiliency Timing Solution for LLS-C4 configuration with Time backup from T-GM. + +Figure 8.2.4-12 illustrates primary (GNSS/PRTC) and backup (PTP) synchronization path for LLS-C4 based topologies. + +Primary source: O-RU/O-DU will be synced using the GNSS Receiver. + +Backup source: T-GM sourcing the clock through T-BC (CSR) towards O-DU and O-RU. Upon any GPS fault O-RU(s)/O-DU(s), will switch over to PTP mode (T-TSC clock). + +![Figure 8.2.4-12: Resiliency for C4 configuration with Time/phase backup from T-GM. The diagram shows a network topology for co-located DU/RUs. At the center is a green box labeled 'T-BC CSR'. Below it is a yellow box labeled 'PRTC/T-GM'. To the left are two blue boxes labeled 'O-RU PRTC/T-TSC'. To the right are two blue boxes labeled 'PRTC/T-TSC O-DU1' and 'PRTC/T-TSC O-DU2'. Red lines represent fronthaul connections between the T-BC CSR and the O-RUs and O-DUs. A legend at the bottom indicates that red lines are 'Fronthaul' and a line with a circle and arrow is 'Standby PTP(Time)'.](49866a757a27c5e56a53b1180d58c283_img.jpg) + +Figure 8.2.4-12: Resiliency for C4 configuration with Time/phase backup from T-GM. The diagram shows a network topology for co-located DU/RUs. At the center is a green box labeled 'T-BC CSR'. Below it is a yellow box labeled 'PRTC/T-GM'. To the left are two blue boxes labeled 'O-RU PRTC/T-TSC'. To the right are two blue boxes labeled 'PRTC/T-TSC O-DU1' and 'PRTC/T-TSC O-DU2'. Red lines represent fronthaul connections between the T-BC CSR and the O-RUs and O-DUs. A legend at the bottom indicates that red lines are 'Fronthaul' and a line with a circle and arrow is 'Standby PTP(Time)'. + +**Figure 8.2.4-12 Resiliency for C4 configuration with Time/phase backup from T-GM.** + +##### 8.2.4.3.6 Resiliency Timing Solution for LLS-C4/C3(Mixed) configuration for co-located DU/RUs. + +Figure 8.2.4-13 depicts the C4/C3 mixed topology where O-DUs shall be operating in LLS-C3 mode synchronizing the clock from PTP network while O-RUs will use PRTC/GNSS sync as primary sync method. Example deployment will be outdoor small cell deployments (co-located DU/RUs) where RUs will have GNSS sync source while DUs might still rely on PTP synchronization. + +Primary: O-RU uses GNSS(PRTC) as primary synchronization source. O-DU gets synchronized with T-GM-A through CSR1/CSR2. T-GM-A shall be configured with higher priority (lower priority2 value) compared to T-GM-B. Ports on CSR1/CSR2 connected towards T-GM-A are configured with high priority (local Priority for PTP, SyncE priority/ESMC clock quality level) compared to those ports towards T-GM-B so that A-BTCA choses T-GM-A as PTP and Sync-E clock source towards O-DUs when both GMs are active. + +Failover path: + +O-RUs: Any GNSS failure at O-RU(s), RU shall now operate in T-TSC clock mode and use PTP synchronization from T-GM-A/T-GM-B through CSR1/CSR2 as a Time/frequency backup. + +O-DUs: When T-GM-A GNSS fails, the backup synchronization path for O-DU shall be from T-GM-B through CSR1/CSR2. T-GM-B shall be selected by O-DUs, as per A-BTCA due to superior clock values advertised by T-GM-B compared to T-GM-A, which is in holdover. Further, O-DUs would switch over to the Sync-E from T-GM-B as it is superior to T-GM-A in holdover. + +1 + +![Figure 8.2.4-13: Resiliency for LLS-C4/C3(Mixed) configuration with backup from T-GM for co-located DU(s)/RU(s). The diagram shows a central vertical backbone with two T-BC CSR blocks (CSR-1 and CSR-2). Above CSR-1 is a PRTC/T-GM-A block, and below CSR-2 is a PRTC/T-GM-B block. On the left, four O-RU PRTC/T-TSC blocks are connected to the backbone via A-BTCA links. On the right, four T-TSC O-DU blocks are connected to the backbone. Red lines represent Fronthaul connections. Blue arrows represent Active PTP, and grey arrows represent Standby PTP. A legend at the bottom identifies these connections.](35902e86858e9326c254dae18ff5e737_img.jpg) + +Cell sites (DU, RU co-located) + +— Fronthaul    ← Active PTP    ← Standby PTP + +Figure 8.2.4-13: Resiliency for LLS-C4/C3(Mixed) configuration with backup from T-GM for co-located DU(s)/RU(s). The diagram shows a central vertical backbone with two T-BC CSR blocks (CSR-1 and CSR-2). Above CSR-1 is a PRTC/T-GM-A block, and below CSR-2 is a PRTC/T-GM-B block. On the left, four O-RU PRTC/T-TSC blocks are connected to the backbone via A-BTCA links. On the right, four T-TSC O-DU blocks are connected to the backbone. Red lines represent Fronthaul connections. Blue arrows represent Active PTP, and grey arrows represent Standby PTP. A legend at the bottom identifies these connections. + +2 + +3 + +4 + +5 + +**Figure 8.2.4-13 Resiliency for LLS-C4/C3(Mixed) configuration with backup from T-GM for co-located DU(s)/RU(s).** + +6 + +7 + +##### 8.2.4.3.7 Resiliency Timing Solution for LLS-C4/C3(Mixed) configuration for DUs on CDC/GC/Hub site. + +8 + +9 + +10 + +11 + +12 + +Figure 8.2.4-14 depicts the C4/C3 mixed topology where O-DUs shall be operating in LLS-C3 mode synchronizing the clock from PTP network while O-RUs will use PRTC/GNSS sync as primary time source. An example deployment model would be an outdoor small cell deployments where RUs will have GNSS sync source while DUs located in CDC/GC site might still rely on PTP synchronization. + +13 + +14 + +15 + +16 + +17 + +18 + +19 + +20 + +Primary: O-RU uses GNSS (PRTC) as primary synchronization source. Sync path for O-DUs shall be T-GM-A through HSR-A/HSR-B, and CSRs. O-DU is T-TSC Clock. T-GM-A shall be configured with higher priority(lower priority2 value) compared to T-GM-B. Ports on HSR-A/HSR-B connected towards T-GM-A are configured with high priority (localPriority for PTP, Sync-E priority/ESMC clock quality level) compared to those ports towards T-GM-B so that A-BTCA choses T-GM-A as PTP clock source and for Sync-E the ports with higher priority will be chosen as clock source towards O-DUs when both T-GMs are active. + +1 + +![Figure 8.2.4-14: Resiliency for C4/C3(Mixed) configuration with backup from T-GM and DUs in CDC/GC. The diagram illustrates a network topology for resiliency. On the left, 'Cell sites' contain O-RU T-TSC blocks connected to T-BC CSR blocks. In the center, 'Hub Site' contains T-BC HSR blocks (A, B, F1, Fn) and PRTC/T-GM blocks (A, B). On the right, O-DU blocks (O-DU1, O-DU2, O-DUn-1, O-DUn) are connected to T-TSC blocks. Connections are color-coded: red for Fronthaul, yellow for Midhaul, and green for Backhaul. Blue arrows represent 'Active PTP' and grey arrows represent 'Standby PTP'. A-BTCA connections are shown between T-BC blocks and T-TSC blocks. A legend at the bottom identifies the connection types and PTP states.](3dd5a7d4cb30c3806c56c78007ac8b33_img.jpg) + +Figure 8.2.4-14: Resiliency for C4/C3(Mixed) configuration with backup from T-GM and DUs in CDC/GC. The diagram illustrates a network topology for resiliency. On the left, 'Cell sites' contain O-RU T-TSC blocks connected to T-BC CSR blocks. In the center, 'Hub Site' contains T-BC HSR blocks (A, B, F1, Fn) and PRTC/T-GM blocks (A, B). On the right, O-DU blocks (O-DU1, O-DU2, O-DUn-1, O-DUn) are connected to T-TSC blocks. Connections are color-coded: red for Fronthaul, yellow for Midhaul, and green for Backhaul. Blue arrows represent 'Active PTP' and grey arrows represent 'Standby PTP'. A-BTCA connections are shown between T-BC blocks and T-TSC blocks. A legend at the bottom identifies the connection types and PTP states. + +2 + +3 + +4 + +5 + +6 + +7 + +8 + +9 + +10 + +11 + +12 + +13 + +14 + +**Figure 8.2.4-14 : Resiliency for C4/C3(Mixed) configuration with backup from T-GM and DUs in CDC/GC.** + +Failover path: + +O-RUs: Any GNSS failure at O-RU(s), the O-RU shall transition to operate in T-TSC clock mode and use PTP synchronization from T-GM-A/T-GM-B through HSRs, CSRs as time/frequency backup. + +O-DUs: On T-GM-A failure, the backup synchronization path for O-DUs shall be from T-GM-B through HSRs and O-DUs. + +##### 8.2.4.3.8 Resiliency with LLS-C2/C3 hybrid topology with O-DUs co-located in Hub/Data Center + +![Figure 8.2.4-15: LLS-C2/C3 mixed topology model diagram. The diagram shows a network architecture with Cell sites and a Hub Site. Cell sites contain O-RUs (O-RU1, O-RU2, O-RU3, ..., O-RUn) which are T-TSCs. These are connected to T-BCs (T-BC CSR1, T-BC CSR2, ..., T-BC CSRn) at the Cell sites. The Hub Site contains T-BCs (T-BC HSR-2, T-BC HSR-3, ..., T-BC HSR-5) and T-GMs (T-GM O-DU1, T-GM O-DU2, T-GM O-DU3, ..., T-GM O-DUn). A central PRTC/T-GM A block is also present. Connections are shown for Active PTP (blue arrows) and Standby PTP (grey arrows). Red lines represent Fronthaul connections, and yellow lines represent Midhaul connections. The diagram illustrates the primary sync path from O-DU1 through HSR-2, HSR-4, CSR-1 to O-RU1 and O-RU2, and another path from O-DU1 through HSR-2, HSR-4, CSR-2 to O-RU3 and O-RUn.](e1e296bb61dab365ba4c0d41eaeca55d_img.jpg) + +Figure 8.2.4-15: LLS-C2/C3 mixed topology model diagram. The diagram shows a network architecture with Cell sites and a Hub Site. Cell sites contain O-RUs (O-RU1, O-RU2, O-RU3, ..., O-RUn) which are T-TSCs. These are connected to T-BCs (T-BC CSR1, T-BC CSR2, ..., T-BC CSRn) at the Cell sites. The Hub Site contains T-BCs (T-BC HSR-2, T-BC HSR-3, ..., T-BC HSR-5) and T-GMs (T-GM O-DU1, T-GM O-DU2, T-GM O-DU3, ..., T-GM O-DUn). A central PRTC/T-GM A block is also present. Connections are shown for Active PTP (blue arrows) and Standby PTP (grey arrows). Red lines represent Fronthaul connections, and yellow lines represent Midhaul connections. The diagram illustrates the primary sync path from O-DU1 through HSR-2, HSR-4, CSR-1 to O-RU1 and O-RU2, and another path from O-DU1 through HSR-2, HSR-4, CSR-2 to O-RU3 and O-RUn. + +Figure 8.2.4-15 is an example for the LLS-C2/C3 mixed topology model, where O-DUs acting as GM are co-located at Hub/DC while O-RUs at cell sites are connected to DUs in the fronthaul network. All O-DUs primary mode of operation is GM, secondary mode of operation is T-TSC. In case of GNSS failure, the O-DU is expected to transition from T-GM to T-TSC mode of operation. All O-DUs operating in GM mode are provisioned with priority2 configuration that is prioritized over T-GM A. Priority2 values among the O-DUs are in the order of decreasing priority from O-DU1 to O-DUn. + +The Fronthaul ports on the O-DUs are operating in TimeTransmitter role as long as O-DUs operating as GM (LLS-C2 mode). The O-DUs would transition to TimeReceiver role on GNSS failure (T-TSC mode - LLS-C3 config model). + +Primary (Active PTP) Sync path: Under normal working condition all O-DUs operate as GM: + +O-DU1 -> HSR-2 -> HSR-4 -> CSR-1 -> O-RU1, ORU2 + +O-DU1 -> HSR-2 -> HSR-4 -> CSR-2 -> O-RU3, ORUn + +![Figure 8.2.4-15: Resiliency for LLS-C2/C3 mixed topology with co-located DUs acting as GM. The diagram shows a network topology with Cell sites (O-RU1, O-RU2, O-RU3, ..., O-RUn) connected to a Hub Site (T-BC CSR1, T-BC HSR-4, T-BC HSR-2, T-BC HSR-5, T-BC HSR-3, T-GM O-DU1, T-GM O-DU2, T-GM O-DU3, ..., T-GM O-DUn). The Hub Site is connected to HSR-1. The diagram illustrates the failover sync path for O-DU1 when its GNSS fails, transitioning to T-TSC mode and synchronizing the clock from the neighbouring O-DU2 through the HSR-2 while the O-RU's clock synchronization path would remain same from HSR-2. The diagram includes a legend for Active PTP (blue arrow) and Standby PTP (grey arrow), and a legend for Fronthaul (red line) and Midhaul (yellow line).](b27f64804367618e87365286c3ee1324_img.jpg) + +Figure 8.2.4-15: Resiliency for LLS-C2/C3 mixed topology with co-located DUs acting as GM. The diagram shows a network topology with Cell sites (O-RU1, O-RU2, O-RU3, ..., O-RUn) connected to a Hub Site (T-BC CSR1, T-BC HSR-4, T-BC HSR-2, T-BC HSR-5, T-BC HSR-3, T-GM O-DU1, T-GM O-DU2, T-GM O-DU3, ..., T-GM O-DUn). The Hub Site is connected to HSR-1. The diagram illustrates the failover sync path for O-DU1 when its GNSS fails, transitioning to T-TSC mode and synchronizing the clock from the neighbouring O-DU2 through the HSR-2 while the O-RU's clock synchronization path would remain same from HSR-2. The diagram includes a legend for Active PTP (blue arrow) and Standby PTP (grey arrow), and a legend for Fronthaul (red line) and Midhaul (yellow line). + +Figure 8.2.4-15 : Resiliency for LLS-C2/C3 mixed topology with co-located DUs acting as GM. + +The topology shown in Figure 8.2.4-16, when the O-DU1 GNSS fails, it would transition to T-TSC mode of operation and synchronizes the clock from the neighbouring O-DU2 through the HSR-2 while the O-RU's clock synchronization path would remain same from HSR-2. + +Failover sync path: + +O-DU2 -> HSR-2 -> O-DU1 + +O-DU2 -> HSR-2 -> HSR-4 -> CSR-1 -> O-RU1, O-RU2 + +O-DU2 -> HSR-2 -> HSR-4 -> CSR-2 -> O-RU3, O-RUn + +![Figure 8.2.4-16: Resiliency for LLS-C2/C3 mixed topology with co-located DUs acting as GM. The diagram shows a network topology similar to Figure 8.2.4-15, but with O-DU1 in T-TSC mode (indicated by a red 'X' over the GNSS icon). The failover sync path is shown: O-DU2 -> HSR-2 -> O-DU1. The diagram includes a legend for Active PTP (blue arrow) and Standby PTP (grey arrow), and a legend for Fronthaul (red line) and Midhaul (yellow line).](df2822064ccdec5aba6a7a3b1417d7ee_img.jpg) + +Figure 8.2.4-16: Resiliency for LLS-C2/C3 mixed topology with co-located DUs acting as GM. The diagram shows a network topology similar to Figure 8.2.4-15, but with O-DU1 in T-TSC mode (indicated by a red 'X' over the GNSS icon). The failover sync path is shown: O-DU2 -> HSR-2 -> O-DU1. The diagram includes a legend for Active PTP (blue arrow) and Standby PTP (grey arrow), and a legend for Fronthaul (red line) and Midhaul (yellow line). + +Figure 8.2.4-16 : O-DU1 GNSS failure and clock path changes with LLS-C2/C3 mixed case + +The topology shown in Figure 8.2.4-17, when all O-DUs connected GNSS fails (due to GPS/GNSS geographical issues local to that Hub or datacenter), the O-DUs and O-RUs in the Fronthaul networks would failover to and synchronize from external GM (T-GM A). The Fronthaul networks switches to the LLS-C3 config mode from the LLS-C2 config mode of operation. During this failover, all the O-DUs would transition to T-TSC clock mode of operation from GM mode of operation. On HSR-2 and HSR-3, the clock received on the port connected to HSR-4 is prioritized (marked in green) over the clock received on the port connected to HSR-5 (marked in grey). + +Failover sync path: + +T-GM A -> HSR-4 -> HSR -2 -> O-DU1 & O-DU2 +T-GM-A -> HSR-4 -> HSR-3 -> O-DU-3 & O-DUn +T-GM A -> HSR-4 -> CSR-1 -> O-RU1 & O-RU2 +T-GM-A -> HSR-4 -> CSR-2 -> O-RU3 & O-RUn + +![Figure 8.2.4-17: Network topology diagram showing clock synchronization paths between Cell sites and a Hub Site. Cell sites include O-RU1, O-RU2, O-RU3, and O-RUn, each connected to a T-TSC. These are connected via T-BC (CSR1, CSR2) to the Hub Site. The Hub Site includes T-BC (HSR-4, HSR-5), T-BC (HSR-2, HSR-3), and T-TSC (O-DU1, O-DU2, O-DU3, O-DUn). A PRTC/T-GM A block is also present. Red lines indicate Fronthaul connections, and yellow lines indicate Midhaul connections. Blue arrows show Active PTP paths, and grey arrows show Standby PTP paths. A red 'X' icon is shown above O-DU1.](e84fbdd79ea19368affbce275d267fe2_img.jpg) + +The diagram illustrates a network topology for clock synchronization. On the left, 'Cell sites' are represented by O-RU1, O-RU2, O-RU3, and O-RUn, each connected to a T-TSC. These are connected via T-BC (CSR1, CSR2) to the Hub Site. The Hub Site includes T-BC (HSR-4, HSR-5), T-BC (HSR-2, HSR-3), and T-TSC (O-DU1, O-DU2, O-DU3, O-DUn). A PRTC/T-GM A block is also present. Red lines indicate Fronthaul connections, and yellow lines indicate Midhaul connections. Blue arrows show Active PTP paths, and grey arrows show Standby PTP paths. A red 'X' icon is shown above O-DU1. + +Figure 8.2.4-17: Network topology diagram showing clock synchronization paths between Cell sites and a Hub Site. Cell sites include O-RU1, O-RU2, O-RU3, and O-RUn, each connected to a T-TSC. These are connected via T-BC (CSR1, CSR2) to the Hub Site. The Hub Site includes T-BC (HSR-4, HSR-5), T-BC (HSR-2, HSR-3), and T-TSC (O-DU1, O-DU2, O-DU3, O-DUn). A PRTC/T-GM A block is also present. Red lines indicate Fronthaul connections, and yellow lines indicate Midhaul connections. Blue arrows show Active PTP paths, and grey arrows show Standby PTP paths. A red 'X' icon is shown above O-DU1. + +Figure 8.2.4-17 : All O-DUs GNSS failure and clock path changes with LLS-C2/C3 mixed case + +##### 8.2.4.3.9 Resiliency Timing Solution by LLS-C3 configuration for Shared O-RU + +For Shared O-RU using a common transport network managed by Shared O-RU host (i.e., SRO 1), the resiliency solution will not differ from the non-Shared O-RU case. Therefore it is not discussed here. + +For Shared O-RU supported by separated transport networks that are managed by different SROs, each of SROs takes its own responsibility to the resiliency design to its transport network. Figure 8.2.4-18 shows an + +example of full resiliency solution from both SROs with dual protection mechanism, with A-BTCA function at each stage, when necessary the switching between Active and Standby PTP paths can be achieved. + +![Figure 8.2.4-18: Resiliency Timing Solution for Shared O-RU with separated transport. The diagram illustrates a dual-protected timing architecture. A central 'Managed by Shared O-RU Host' area contains two main sections: 'Managed by SRO 1' and 'Managed by SRO 2'. Each section includes a T-BC HSR (High-Speed Ring) and a T-BC CSR (Clock Source Register). The HSRs are connected to PRTC/T-GM (Precision Time Reference/Clock Management) blocks. The CSRs are connected to T-TSC (Time Synchronization Clock) blocks. The diagram shows active PTP (Precision Time Protocol) paths in blue and standby PTP paths in grey. A-BTCA (Active-BTCA) functions are shown at various stages, enabling switching between active and standby paths. The T-TSC blocks are connected to O-DU (Open Distributed Unit) blocks for SRO 1 and SRO 2.](c5be85f763d7998937670ee966f23ab3_img.jpg) + +The diagram illustrates a dual-protected timing architecture for a Shared O-RU. It shows two main sections: 'Managed by SRO 1' and 'Managed by SRO 2'. Each section contains a T-BC HSR (High-Speed Ring) and a T-BC CSR (Clock Source Register). The HSRs are connected to PRTC/T-GM (Precision Time Reference/Clock Management) blocks. The CSRs are connected to T-TSC (Time Synchronization Clock) blocks. The diagram shows active PTP (Precision Time Protocol) paths in blue and standby PTP paths in grey. A-BTCA (Active-BTCA) functions are shown at various stages, enabling switching between active and standby paths. The T-TSC blocks are connected to O-DU (Open Distributed Unit) blocks for SRO 1 and SRO 2. + +Figure 8.2.4-18: Resiliency Timing Solution for Shared O-RU with separated transport. The diagram illustrates a dual-protected timing architecture. A central 'Managed by Shared O-RU Host' area contains two main sections: 'Managed by SRO 1' and 'Managed by SRO 2'. Each section includes a T-BC HSR (High-Speed Ring) and a T-BC CSR (Clock Source Register). The HSRs are connected to PRTC/T-GM (Precision Time Reference/Clock Management) blocks. The CSRs are connected to T-TSC (Time Synchronization Clock) blocks. The diagram shows active PTP (Precision Time Protocol) paths in blue and standby PTP paths in grey. A-BTCA (Active-BTCA) functions are shown at various stages, enabling switching between active and standby paths. The T-TSC blocks are connected to O-DU (Open Distributed Unit) blocks for SRO 1 and SRO 2. + +**Figure 8.2.4-18 Resiliency Timing Solution for Shared O-RU with separated transport** + +The SRO that supplies the primary timing/sync to the shared O-RU may expect to provide a full resiliency solution to ensure the overall Shared O-RU operation. While the secondary SRO can choose to have a simple resiliency design upon its own reliability requirement for its O-DU. + +#### 8.2.4.4 ePRTC Resiliency + +High availability is one of the key requirements for 5G. It is important to design the 5G synchronization to be highly available with redundancy integrated at all levels of the synchronization infrastructure starting from the source of timing. The resiliency of the timing source is critical to achieve an overall goal of a survivable and fault tolerant synchronization infrastructure. It is essential that the timing infrastructure continues to maintain an acceptable level of service in the event of failures and faults affecting normal operations. + +There is a growing number of intentional and unintentional GNSS incidents. During such extended GNSS outages, ePRTC-A systems operating as an autonomous primary reference clocks can be deployed to maintain time and frequency service in a geographical area. ePRTC-A delivers a high-level of service reliability to ensure operators maintain an acceptable time and frequency service performance for a long period of GNSS unavailability. The frequency stability of a Cesium atomic clock serves as a reference for the ePRTC-A Time Scale. + +ePRTC-A offers the following features: + +- Reliability: Immunity from local jamming or outages +- Autonomy: Atomic clock sustained timescale with & without GNSS connection +- Holdover: 14-day time holdover $\leq 100$ ns + +When an ePRTC-A loses all its input phase and time references, it enters the phase/time holdover state and relies on an autonomous primary frequency reference input (e.g., 2MHz, 10MHz, etc.) to deliver time and phase. This autonomous primary reference clock is typically a Cesium atomic clock. Refer Figure 8.2.4-19, for an ePRTC-A, from the start of phase/time holdover, after 30 days of continuous normal operation, the time output should be accurate, when verified against the applicable primary time standard (e.g., UTC), to within a value increasing linearly from 30 ns to 100 ns over a 14-day period. + +![Figure 8.2.4-19: PRTC-A phase/time holdover requirements. A line graph showing time error in nanoseconds (ns) over time in seconds (s). The y-axis ranges from -100 ns to 100 ns, with major grid lines at -100, -30, 0, 30, and 100. The x-axis ranges from 0 to 1,209,600 s, with major grid lines at 0, 500,000, 1,000,000, and 1,209,600. Two blue lines represent the holdover requirements: one starting at 30 ns at t=0 and increasing linearly to 100 ns at t=1,209,600 s; the other starting at -30 ns at t=0 and decreasing linearly to -100 ns at t=1,209,600 s. The lines are symmetric about the 0 ns line.](2a383147760402c4ad00252b66422853_img.jpg) + +**Time error $\Delta x(t)$** + +| Time (s) | Upper Bound Time Error (ns) | Lower Bound Time Error (ns) | +|-----------|-----------------------------|-----------------------------| +| 0 | 30 | -30 | +| 500,000 | 50 | -50 | +| 1,000,000 | 70 | -70 | +| 1,209,600 | 100 | -100 | + +Figure 8.2.4-19: PRTC-A phase/time holdover requirements. A line graph showing time error in nanoseconds (ns) over time in seconds (s). The y-axis ranges from -100 ns to 100 ns, with major grid lines at -100, -30, 0, 30, and 100. The x-axis ranges from 0 to 1,209,600 s, with major grid lines at 0, 500,000, 1,000,000, and 1,209,600. Two blue lines represent the holdover requirements: one starting at 30 ns at t=0 and increasing linearly to 100 ns at t=1,209,600 s; the other starting at -30 ns at t=0 and decreasing linearly to -100 ns at t=1,209,600 s. The lines are symmetric about the 0 ns line. + +G.8272.1-Y.1367.1(16)\_F03 + +**Figure 8.2.4-19 : PRTC-A phase/time holdover requirements** + +The Figure 8.2.4-20 and Figure 8.2.4-21 below compares the performance of the ePRTC-A, PRTC-A and PRTC-B clocks using the MTIE and TDEV metrics: + +![Figure 8.2.4-20: MTIE for ePRTC-A, PRTC-A and PRTC-B clocks. This is a log-log plot showing Maximum Time Interval Error (MTIE) in seconds on the y-axis (ranging from 1 ns to 1 μs) versus time in seconds on the x-axis (ranging from 0.1 s to 10 Ms). Three curves are shown: PRTC-A (magenta), PRTC-B (red), and ePRTC-A (blue). PRTC-A shows the highest MTIE, increasing from ~30 ns at 0.1 s to ~100 ns at 1 ks. PRTC-B shows a lower MTIE, increasing from ~10 ns at 0.1 s to ~30 ns at 100 ks. ePRTC-A shows the lowest MTIE, increasing from ~5 ns at 0.1 s to ~15 ns at 10 Ms.](177e83bf224174fd318aac2555272c4a_img.jpg) + +Figure 8.2.4-20: MTIE for ePRTC-A, PRTC-A and PRTC-B clocks. This is a log-log plot showing Maximum Time Interval Error (MTIE) in seconds on the y-axis (ranging from 1 ns to 1 μs) versus time in seconds on the x-axis (ranging from 0.1 s to 10 Ms). Three curves are shown: PRTC-A (magenta), PRTC-B (red), and ePRTC-A (blue). PRTC-A shows the highest MTIE, increasing from ~30 ns at 0.1 s to ~100 ns at 1 ks. PRTC-B shows a lower MTIE, increasing from ~10 ns at 0.1 s to ~30 ns at 100 ks. ePRTC-A shows the lowest MTIE, increasing from ~5 ns at 0.1 s to ~15 ns at 10 Ms. + +Figure 8.2.4-20 : MTIE for ePRTC-A, PRTC-A and PRTC-B clocks + +![Figure 8.2.4-21: TDEV for ePRTC-A, PRTC-A and PRTC-B clocks. This is a log-log plot showing Time Deviation (TDEV) in seconds on the y-axis (ranging from 100 ps to 100 ns) versus time in seconds on the x-axis (ranging from 1 s to 1 Ms). Three curves are shown: PRTC-A (magenta), PRTC-B (red), and ePRTC-A (blue). PRTC-A shows the highest TDEV, increasing from ~10 ns at 1 s to ~30 ns at 100 s. PRTC-B shows a lower TDEV, increasing from ~5 ns at 1 s to ~15 ns at 100 s. ePRTC-A shows the lowest TDEV, increasing from ~1 ns at 1 s to ~10 ns at 1 Ms.](312a22bb17f030ec1a951ca6dff07ec5_img.jpg) + +Figure 8.2.4-21: TDEV for ePRTC-A, PRTC-A and PRTC-B clocks. This is a log-log plot showing Time Deviation (TDEV) in seconds on the y-axis (ranging from 100 ps to 100 ns) versus time in seconds on the x-axis (ranging from 1 s to 1 Ms). Three curves are shown: PRTC-A (magenta), PRTC-B (red), and ePRTC-A (blue). PRTC-A shows the highest TDEV, increasing from ~10 ns at 1 s to ~30 ns at 100 s. PRTC-B shows a lower TDEV, increasing from ~5 ns at 1 s to ~15 ns at 100 s. ePRTC-A shows the lowest TDEV, increasing from ~1 ns at 1 s to ~10 ns at 1 Ms. + +Figure 8.2.4-21 : TDEV for ePRTC-A, PRTC-A and PRTC-B clocks + +In the event of GNSS outage the synchronization infrastructure will rely on the ePRTC-A systems to deliver an acceptable frequency and time service to the network for an extended period. It is important to make sure that these ePRTC-A systems are highly reliable. + +The robustness of the ePRTC-A system resiliency can be optionally enhanced with an ensemble function involving two Cesium atomic clocks as shown in Figure 8.2.4-22. The ensemble function continuously measures and compares the stability of the individual Cesium atomic clocks and possibly gracefully de-weight one of the Cesium from influencing the service if it ever degrades in performance. + +![Figure 8.2.4-22: ePRTC system backed up with two Cesium atomic clocks. The diagram shows a central ePRTC-A block. A GNSS antenna is connected to the top of the block. Two Cesium atomic clocks are connected to the left side of the block: one is a solid box labeled 'Cesium atomic clock' and the other is a dashed box labeled 'Cesium atomic clock'. Both are connected to an 'Ensembling function' block inside the ePRTC-A. On the right side of the ePRTC-A block, three outputs are shown: 'Time reference (e.g., 1PPS)', 'Phase reference (e.g., PTP)', and 'Frequency reference (e.g., 2 048 KHz)'.](a768b2f714d6894cabbc427060a42aae_img.jpg) + +Figure 8.2.4-22: ePRTC system backed up with two Cesium atomic clocks. The diagram shows a central ePRTC-A block. A GNSS antenna is connected to the top of the block. Two Cesium atomic clocks are connected to the left side of the block: one is a solid box labeled 'Cesium atomic clock' and the other is a dashed box labeled 'Cesium atomic clock'. Both are connected to an 'Ensembling function' block inside the ePRTC-A. On the right side of the ePRTC-A block, three outputs are shown: 'Time reference (e.g., 1PPS)', 'Phase reference (e.g., PTP)', and 'Frequency reference (e.g., 2 048 KHz)'. + +**Figure 8.2.4-22 : ePRTC system backed up with two Cesium atomic clocks** + +The robustness of the ePRTC-A system resiliency can be further enhanced using a backup ePRTC-A that is connected to the two Cesium atomic clocks as shown in Figure 8.2.4-23. + +![Figure 8.2.4-23: Redundant ePRTC-A system backed up with two Cesium atomic clocks. The diagram shows two ePRTC-A blocks stacked vertically. A GNSS antenna is connected to the top of the upper ePRTC-A block. Two Cesium atomic clocks (one solid box, one dashed box) are connected to the left side of both ePRTC-A blocks. Each clock is connected to the 'Ensembling function' block of both the upper and lower ePRTC-A blocks. On the right side of each ePRTC-A block, three outputs are shown: 'Time reference (e.g., 1PPS)', 'Phase reference (e.g., PTP)', and 'Frequency reference (e.g., 2 048 KHz)'.](022c12834266f54c4c54cdea0407fd25_img.jpg) + +Figure 8.2.4-23: Redundant ePRTC-A system backed up with two Cesium atomic clocks. The diagram shows two ePRTC-A blocks stacked vertically. A GNSS antenna is connected to the top of the upper ePRTC-A block. Two Cesium atomic clocks (one solid box, one dashed box) are connected to the left side of both ePRTC-A blocks. Each clock is connected to the 'Ensembling function' block of both the upper and lower ePRTC-A blocks. On the right side of each ePRTC-A block, three outputs are shown: 'Time reference (e.g., 1PPS)', 'Phase reference (e.g., PTP)', and 'Frequency reference (e.g., 2 048 KHz)'. + +**Figure 8.2.4-23 : Redundant ePRTC-A system backed up with two Cesium atomic clocks** + +The ePRTC-A systems are typically deployed in core and large hub sites to deliver a synchronization service to the smaller Hub sites and cell sites located in a local geographical area as shown in Figure 8.2.4-24. In the event of GNSS outage impacting that area, the ePRTC-A in a holdover state will be able to deliver an acceptable frequency and phase to the Hub and cell sites for up to 14 days. + +![Figure 8.2.4-24: ePRTC-A deployment in core site. The diagram shows a network topology with three main components: Cell site, Hub site, and Core site. The Cell site contains two O-RU blocks connected to a BC block. The Hub site is a central block. The Core site contains two BC blocks connected to a central ePRTC-A block, which is also connected to a Cesium block. The ePRTC-A block has an antenna symbol on top. The connections are as follows: Cell site BC blocks connect to the Hub site. The Hub site connects to the Core site BC blocks. The Core site BC blocks connect to the ePRTC-A block. The ePRTC-A block connects to the Cesium block.](d40bd0d0801dd51311faf382021eeded_img.jpg) + +Figure 8.2.4-24: ePRTC-A deployment in core site. The diagram shows a network topology with three main components: Cell site, Hub site, and Core site. The Cell site contains two O-RU blocks connected to a BC block. The Hub site is a central block. The Core site contains two BC blocks connected to a central ePRTC-A block, which is also connected to a Cesium block. The ePRTC-A block has an antenna symbol on top. The connections are as follows: Cell site BC blocks connect to the Hub site. The Hub site connects to the Core site BC blocks. The Core site BC blocks connect to the ePRTC-A block. The ePRTC-A block connects to the Cesium block. + +**Figure 8.2.4-24 : ePRTC-A deployment in core site** + +A fully redundant ePRTC-A system as shown in Figure 8.2.4-25 allows to protect against most types of failures. The back-up ePRTC-A unit equipped with its own antenna will provide protection against antenna failures, and software/hardware failures. The A-BTCA protocol can be used to select the best ePRTC-A clock. Alternatively, an IP failover mechanism between the two ePRTC-A units can constantly compare their health metrics and switch-over automatically from the active to the back-up unit if the health of the active one becomes degraded. + +Diverse topology (link and node) design is essential to build a survivable network timing infrastructure that distributes time and frequency from the core and hub sites to the cell sites. It is important to protect the distribution of the timing information against link and node failures. The fully redundant ePRTC-A system is connected to the network via two different network access points located on separate physical nodes. A failure at one node or link should not disrupt the delivery of frequency and time/phase to the network. + +The topology shown in Figure 8.2.4-25 illustrates the different types of failures that can be effectively handled using the fully redundant ePRTC-A system. + +- Node failure (failure 1): The ePRTC-A is protected against a failure of the adjacent north side BC node, port or link by switching over to the south side port by A-BTCA. +- Node failure (failure 2): One ePRTC-A node port failure is protected by another ePRTC-A node +- Antenna failure (failure 3): One ePRTC-A is protected against an antenna failure by the selection of the standby ePRTC-A node. +- ePRTC software/hardware failure (failure 4): The ePRTC-A node failure is protected by another ePRTC-A node. + +![Diagram illustrating a fully redundant ePRTC-A deployment in a large Hub site. The diagram shows a Cell site connected to a Large Hub site. The Cell site contains two O-RU blocks connected to two BC blocks. The Large Hub site contains two BC blocks, two ePRTC-A blocks, and a Cesium block. Four failure cases are marked with red 'X' symbols: Failure case 1 (top BC), Failure case 2 (top ePRTC-A), Failure case 3 (top BC to top ePRTC-A link), and Failure case 4 (top ePRTC-A).](03aec077aab7d519af75ce5d1f01c154_img.jpg) + +The diagram illustrates a network architecture with two main sites: a Cell site and a Large Hub site. The Cell site contains two O-RU blocks connected to two BC blocks. The Large Hub site contains two BC blocks, two ePRTC-A blocks, and a Cesium block. Four failure cases are marked with red 'X' symbols: Failure case 1 (top BC), Failure case 2 (top ePRTC-A), Failure case 3 (top BC to top ePRTC-A link), and Failure case 4 (top ePRTC-A). The connections show a redundant path for the ePRTC-A deployment. + +Diagram illustrating a fully redundant ePRTC-A deployment in a large Hub site. The diagram shows a Cell site connected to a Large Hub site. The Cell site contains two O-RU blocks connected to two BC blocks. The Large Hub site contains two BC blocks, two ePRTC-A blocks, and a Cesium block. Four failure cases are marked with red 'X' symbols: Failure case 1 (top BC), Failure case 2 (top ePRTC-A), Failure case 3 (top BC to top ePRTC-A link), and Failure case 4 (top ePRTC-A). + +Figure 8.2.4-25 : Fully redundant ePRTC-A deployment in large Hub site + +1 +2 +3 +4 +5 +6 +7 +8 +9 + +# Annex A Microwave and mmWave radio transport + +## A.1 Conformance to IEEE1588 and PTP profiles + +The Microwave system is capable of supporting PTP functions based on the IEEE1588-2008 or IEEE1588-2019 standards. It also complies with the PTP profile of ITU-T G.8275.1 [1], G.8275.2 [3] and the recommendation for T-TC and T-BC characteristics of Ethernet nodes defined in G.8273.2 [2] and G.8273.3 [4] as a guarantee for specific interoperability and KPI. + +For all practical purposes, microwave devices (and any other media) are outside the scope of the ITU-T recommendations. However, each Microwave vendor can voluntarily declare their products to be equivalent to the standards by guaranteeing KPIs equivalent to these standards. + +In Figure A.1-1 we assume a simple Fronthaul network with LLS-C2 configuration with two possible implementations in (a) and (b) resulting in different number of PTP nodes. + +![Figure A.1-1: Fronthaul transport network model with MW/mmWave radio illustrating two different implementations resulting in different number of PTP nodes.](b0a025008d15da6afd8f327975bb1604_img.jpg) + +The diagram illustrates two implementations of a fronthaul network with microwave/mmWave radio transport. The main diagram shows a flow from a PRTC/ePRTC T-GM through a Midhaul Transport Network (T-BC/T-TC) to an O-DU+T-BC, which then connects to a fronthaul Transport Network (T-BC/T-TC realisation with Multiple MW/mmWave links/hops) and finally to an O-RU+TSC. A PTP/SynchE path is shown connecting the O-DU+T-BC and the fronthaul network. + +(a) Implementation of fronthaul network with cascaded 2 radio I/F path, i.e. 2 hops + Requiring 4 MW/mmWave devices with 1 Ethernet Node, 2 radio links requiring 1 media converter Node plus 1 Ethernet Node resulting in 3 PTP nodes in total. + +(b) Implementation of fronthaul network cascaded 2 radio I/F path, i.e. 2 hops + Requiring 4 MW/mmWave devices with 1 Ethernet Node, 2 radio links requiring 2 media converter nodes plus 1 Ethernet Node resulting in 4 PTP nodes in total. + +Figure A.1-1: Fronthaul transport network model with MW/mmWave radio illustrating two different implementations resulting in different number of PTP nodes. + +**Figure A.1-1 – Fronthaul transport network model with MW/mmWave radio illustrating two different implementations resulting in different number of PTP nodes.** + +## A.2 Impact of Radio channel bandwidth + +Narrowband radio links with small channel bandwidth can impact the packet transmission with large delay. In a small channel bandwidth wireless link, the baseband clock granularity is degraded, which may affect the timing of packet transmission and reception, resulting in degradation of Constant and Dynamic TE characteristics. This may cause deterioration to end-to-end Time Error characteristics, which is further affected by the increase in delay asymmetry. It is therefore necessary to select equipment to be used in the transport network that can take into considering the Time Error (TE) characteristics in its radio channel. Section 10.2.4 on Microwave and mmWave radio Transport Technologies in [32] gives an overview of the bands available for microwave and mmWave radio transport and their corresponding capacity and latency characteristics. + +1 +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 +16 +17 +18 +19 +20 +21 +22 +23 +24 +25 +26 +27 +28 +29 +30 +31 +32 +33 +34 +35 +36 +37 +38 +39 +40 +41 +42 +43 +44 +45 +46 +47 + +## A.3 Impact of interference + +Like all radio communications systems, Point-to-Point (PP) and Point-to-Multiple-Point (PMP) microwave and mmWave radio transport links are susceptible to radio interference from adjacent and parallel links as well from other services, such as radar, Radio LAN and Short-Range devices, that could be sharing the band or operating in adjacent band to the radio transport fixed service. Communication failure may occur due to the influence of this interference, and the (TE) characteristics may deteriorate accordingly. The severity of TE degradation depends on the equipment and the techniques used to mitigate the impact of interference. As such the design and selection of the bands should take into considering TE degradation due to the external environment. Examples of considerations to mitigate the effect of interference, include avoiding the use of license exempt bands for time sensitive applications, use high quality antenna with very low side lobes (e.g., ETSI Class 4), and apply for high protection and availability link licenses, i.e., 99.99% or over. + +## A.4 Impact of dynamic capacity variations + +Microwave and mmWave Point to Point radio systems are designed to operate with high availability by allowing adequate fade margin in their link budget. The fade margin is calculated to compensate the propagation loss depending on the rain intensity in the area they intended to operate. Modern PP radio systems apply Adaptive Coding and Modulation (ACM) technique to boost its link capacity during the clear sky period taking advantage of the fade margin to apply higher order modulation scheme with higher capacity than the one needed during the worst raining period. This allows the PP radio system to transmit at its maximum transmission capacity allowed by the changing weather condition. This dynamic variations in the modulation method can cause deterioration to the TE, because the data size that is processed by the Modem vary significantly between the different ACM schemes. In general, in ACM technology, the packet delay varies with the modulation level. This is caused by changes in the transmission bandwidth, which results by buffer retention of packets and the mapping process to wireless frames. It is therefore necessary to ensure that equipment selected in the network for time sensitive application does not deteriorate the TE characteristics as a result of operation of the ACM technology. + +## A.5 Impact of Band and Carrier Aggregation + +Wireless transport systems operate in a variety of bands ranging from the lower microwave spectrum up to the mmWave above 100 GHz. The characteristics of these bands are summarised in [x1], showing large bandwidth availability in mmWave spectrum but with shorter link length, while the systems operating in the lower bands of the microwave spectrum have longer links with narrower channel bandwidth is available. Band and Carrier Aggregation (BCA) technique combines different channels that may be even in different bands, providing a single big capacity pipe. In particular, BCA allows the combined benefits of the longer hop distance of microwave systems with the high capacity in multiple Gigabits per second of the mmWave bands such as the E-bands and above. However, this BCA pipe will have different propagations losses between the portion of the links operating in the microwave band and the one operating in the mmWave band. Furthermore, these links with multi-band operation would result in part of the links in one direction to disconnect resulting in imbalance between the go and return of the wireless transport link. As such, it is necessary to consider the effects of delay asymmetry and the impact of disconnection in part of the sub-channels over the BCA pipe. It is therefore necessary to carefully verify the effect of the asymmetric effects and the imbalance in the subchannels on the possible deterioration of TE characteristics. + +## A.6 Point to Multi Point (PMP) radio system + +There are three types of systems that are used for the wireless transport system: Point-to-Point (PP), Point-to-Multi-Point (PMP), and Multi-Point-to-Multi-Point (MPMP) such as Mesh radio systems. PMP and MPMP systems have asymmetric UL/DL latency. This limits, its capabilities in achieving good TE characteristics. Equipment that are designed and able to achieve good TE characteristics should only be used for time sensitive application with tight TE requirements. + +## A.7 Radio Interface with asymmetry latency + +The DL/UL delay in the Radio Interface of PP Radio systems are generally symmetric, and the degradation of cTE is small. However, it should be noted that TE due to delay asymmetry of several ns to several tens of ns is inevitable due to radio circuit configuration, filter group delay, and other factors in the radio processing part of the PP system. This phenomenon varies depending on the system configuration such as its channel bandwidth and the environment of the band in which they operate. + +If the total TE of the NW has enough margin, these factors can be regarded as minor errors. However, when designing for a tight total TE of the NW, it is desirable to use a MW node that has the ability to perform static correction of the cTE. + +## A.8 Holdover Spec of BC function on the wireless transport node + +The holdover function of the microwave and mmWave node is required as TE tolerance for the temporary unlock state of a few tens of seconds during timeTransmitter clock rearrangement. However, since the U-plane and the S-plane go down at the same time when the line is down, the long-term holdover capability is meaningless. A TE holdover characteristic of a few hundred ns per few tens of seconds is sufficient as shown in G.8262 [14] or G.8262.1 [15], however, this depends on the assignment of the TE value of the Rearrangement event in the Total TE Budget of the NW. + +## A.9 Considering of characteristics in multiple hops + +In a typical Ethernet node, TE characteristics are specified for a single node. On the other hand, since the input and output ports of MW devices are a pair of Ethernet and Radio or Radio and Radio (Figure A.1-1), there are cases where it is necessary to evaluate the TE characteristics of multiple nodes cumulatively. + +Table A.9-1 and Table A.9-2 show the characteristics when multiple nodes are accumulated. + +(Note: This value is not applicable in the case of NWs with mixed T-BC and T-TC). + +The values shown in these tables are calculated values based on the formulae for cascading ITU-T G.8273.2 [2] and G.8273.3 [4] nodes. Although the values are based on the accumulation of Ethernet nodes, they can also be applied to the accumulation of microwave nodes if the vendor guarantees the same KPIs as for Ethernet nodes. + +For example, at the intermediate site between hops, two MW/mmWave devices are used back-to-back. These maybe connected by an Ethernet interface as illustrated in Figure A.1-1(b). In this case, we may count the Ethernet Switch between the radios and Radio IF portions of the Microwave node as separate PTP Nodes. On the other hand, there may be a case where the Microwave devices are connected seamlessly without an Ethernet interface between them as illustrated in the model of Figure A.1-1 (a). In this case the radio interface is counted as one PTP node. In the ITU-T definition, the Ethernet interface is the reference point, but in Microwave devices, the vendor has to define the reference point for the interface. + +The user should consider the NW TE budget based on these counting methods. + +| ClassA | Single Node | 2nodes | 3nodes | 4nodes | 5nodes | 6nodes | 7nodes | 8nodes | 9nodes | 10nodes | +|-------------------------|-------------|--------|--------|--------|--------|--------|--------|--------|--------|---------| +| Max TE | 100 | 160 | 220 | 280 | 340 | 400 | 460 | 520 | 570 | 630 | +| cTE | 50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | +| dTE <sub>L</sub> (MTIE) | 40 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 120 | 130 | +| dTE <sub>L</sub> (TDEV) | 4 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 12 | 13 | +| dTE <sub>H</sub> | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | +| ClassB | Single Node | 2nodes | 3nodes | 4nodes | 5nodes | 6nodes | 7nodes | 8nodes | 9nodes | 10nodes | +| Max TE | 70 | 100 | 130 | 160 | 190 | 220 | 250 | 280 | 300 | 330 | +| cTE | 20 | 40 | 60 | 80 | 100 | 120 | 140 | 160 | 180 | 200 | +| dTE <sub>L</sub> (MTIE) | 40 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 120 | 130 | +| dTE <sub>L</sub> (TDEV) | 4 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 12 | 13 | +| dTE <sub>H</sub> | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | + +Note) Calculated based on the calculation policies of G.8273.2 [2] Appendix-V. + +**Table A.9-1: Microwave T-TB Noise accumulation (Class-A and B)** + +| ClassA | Single Node | 2nodes | 3nodes | 4nodes | 5nodes | 6nodes | 7nodes | 8nodes | 9nodes | 10nodes | +|-------------------------|-------------|--------|--------|--------|--------|--------|--------|--------|--------|---------| +| Max TE | 100 | 180 | 250 | 315 | 375 | 440 | 505 | 565 | 620 | 680 | +| cTE | 50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | +| dTE <sub>L</sub> (MTIE) | 40 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 120 | 130 | +| dTE <sub>L</sub> (TDEV) | FFS | FFS | FFS | FFS | FFS | FFS | FFS | FFS | FFS | FFS | +| dTE <sub>H</sub> | 70 | 100 | 130 | 140 | 160 | 180 | 190 | 200 | 210 | 230 | +| ClassB | Single Node | 2nodes | 3nodes | 4nodes | 5nodes | 6nodes | 7nodes | 8nodes | 9nodes | 10nodes | +| Max TE | 70 | 120 | 160 | 195 | 225 | 260 | 295 | 325 | 350 | 380 | +| cTE | 20 | 40 | 60 | 80 | 100 | 120 | 140 | 160 | 180 | 200 | +| dTE <sub>L</sub> (MTIE) | 40 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 120 | 130 | +| dTE <sub>L</sub> (TDEV) | FFS | FFS | FFS | FFS | FFS | FFS | FFS | FFS | FFS | FFS | +| dTE <sub>H</sub> | 70 | 100 | 130 | 140 | 160 | 180 | 190 | 200 | 210 | 230 | + +Note) Calculated based on the calculation policies of G.8273.3 [4] Appendix-III. + +**Table A.9-2: Microwave T-TC Noise accumulation (Class-A and B)** + +The tables above show a maximum of 10 nodes; however, this can be extended if the Max |TE| < 1.5 microsec for the total budget of the network. + +# Annex B Radio operation when synchronization is lost + +This section describes the radio operational impacts during the sync loss and recommendations or best practices for Sync plane for handling the Radio operation during the sync loss. All the data processing clocks in O-RU are driven by the S-plane Reference. If S-plane is down, we might lose sync. If O-RU implements Holdover O-RU moves to Holdover state if not O-RU moves to FREE-RUN state. The M-Plane/OAM (Operation and Maintenance modules) detects this S-plane state changes and might initiate shutting down data processing paths and cells will be brought down to inactive state. + +## B.1 Potential impacts due to sync loss on O-RUs + +Usually O-RUs upon losing the lock (due to PTP/Sync-E down) might move to HOLDOVER. At this state cells are still active and continue to be operational as much as they can. The holdover duration needed to maintain the cells to be intact is subject to the holdover characteristics of the Oscillator (ageing, holdover per day etc.), sync accuracy. An oscillator with good holdover characteristics would lead to a slow drift such that the frequency reference is still within tolerance and the clocks don't change too much then we can continue as the cells are effectively still in sync even though they have lost the clock reference. If the frequency is out by too much then the carrier starts drifting across the spectrum - potentially starting to encroach on adjacent signals and causing signal corruption if it drifts beyond guard band. If there is a phase drift happening, then the cell timing is out, and handsets will then exhibit jumps in range that they are not expecting and handover from one cell to another may fail. Further static handsets may see ranging errors increase. During the sync loss its essential to be able to meet 50ppb frequency limit and 3us of Time error (3GPP thresholds) for the cells to be operational without any problems. + +### B.1.1 TAE errors beyond the allowed range during sync loss + +For the case of O-DU connected to multiple O-RUs, Sync loss on one of the connected O-RUs will lead to TAE (Time Alignment errors) between the radio ports of O-RUs crossing the allowed thresholds based on the chosen Air interface targets which will eventually impacts the connected cells and thus bringing down the UEs. + +### B.1.2 Impact on Handover/Handoff + +It is a very basic requirement of the system that as the mobile handset moves out of one cell to the next, it must be possible to hand the call over from the base station of the first cell, to that of the next with no discernible disruption to the call. This is termed as cell handover/handoff. It is necessary to ensure handoff can be performed reliably and without disruption to any calls. handover or handoff is one of the key performance indicators monitored so that a robust cellular handover / handoff regime is maintained on the cellular network. Sync loss on O-RU will impact the cell handoff as the RU starts drifting in phase/frequency when the handset moves from connected cell to the other and leading to call drops. + +![Diagram illustrating Cell handoff / handover. The top part shows a car moving from Cellular Base Station A (Serving Cell A) to Cellular Base Station B (Serving Cell B). The bottom part shows the car moving from Cellular Base Station B (Serving Cell B) to Cellular Base Station A (Serving Cell A). A legend indicates 'Maintain call while moving'.](540dadc39561a7e8538389d147b4eb5d_img.jpg) + +Diagram illustrating Cell handoff / handover. The top part shows a car moving from Cellular Base Station A (Serving Cell A) to Cellular Base Station B (Serving Cell B). The bottom part shows the car moving from Cellular Base Station B (Serving Cell B) to Cellular Base Station A (Serving Cell A). A legend indicates 'Maintain call while moving'. + +Figure B.1.2-1: Cell handoff / handover + +## B.2 Potential impacts due to sync loss on O-DU + +### B.2.1 O-DU Sync loss in LLS-C3 topology + +If O-DU moves to holdover due to upstream timeTransmitter sync loss, then O-DU continue to serve the connected O-RUs for the holdover duration and continues to generate the slot intervals (TTI/SFN numbers) towards the connected O-RUs. The L1/BBU instances on O-DU need TOD to generate SFN/slot intervals. The slot intervals are dependent on the LTE/5G TDD/FDD deployment and sub carrier spacing being used. For example, 5G Sub6 with 30KHz sub carrier spacing will need 125us for slot interval/SFN generation. Sync is needed to maintain the TOD to be able to generate these SFNs at 125us. Once the specified holdover duration expires all the carriers corresponding to this O-DU will be brought down/detached/deleted. If O-DU holdover duration is greater than O-RU in this case cells will be brought down by O-RU before the O-DU detaches the carriers. Any state changes on O-DU will be propagated as an M-Plane events (Netconf/yang) towards O-RU and that's how O-RU knew that O-DU is in Holdover. + +![Diagram illustrating Sync loss due to GNSS failure at T-GM. The diagram shows a T-GM block at the top, connected to a T-BC Switch block below it. The T-BC Switch block is connected to an O-DU block on the left and two O-RU blocks (O-RU1 and O-RU2) on the right. A GNSS symbol is shown above the T-GM block, indicating a failure.](bdd34ab0d8100e4ad2ea3e5c1755b3b8_img.jpg) + +Diagram illustrating Sync loss due to GNSS failure at T-GM. The diagram shows a T-GM block at the top, connected to a T-BC Switch block below it. The T-BC Switch block is connected to an O-DU block on the left and two O-RU blocks (O-RU1 and O-RU2) on the right. A GNSS symbol is shown above the T-GM block, indicating a failure. + +Figure B.2.1-1: Sync loss due to GNSS failure at T-GM + +### B.2.2 O-DU Sync loss in LLS-C1/C2 topology + +If O-DU moves to holdover due to sync loss (either due to GNSS failure on O-DU acting as GM or due to upstream GM failure with O-DU acting as BC), O-DU will move to holdover and continues to serve the connected O-RUs, maintains the slot intervals and symbol intervals. During this holdover duration, all + +connected O-RUs will eventually move to Holdover due to clock class change on O-DU and might bring down the cells post holdover duration subject to holdover durations supported on O-RUs. O-DU should satisfy the $\pm 1.5\mu s$ absolute TE requirements as that of O-RU. + +## B.3 Best Practices + +1. In order to avoid or minimize the impact on the cell's operations, its recommended for O-RUs equipped with Oscillators having good holdover characteristics (low drift) for any type of sync losses. +2. For LLS-C3 deployments with multiple FH links towards O-RU, its recommended to have SyncE and PTP carried in different links so as to avoid Single point of failures for S-plane and allow to extend the O-RU holdover for longer durations with SyncE back up If link carrying PTP is down and thus minimizing the impact on cell operations, avoid cell disruptions. +3. For LLS-C4 deployments where O-RU uses GNSS based local PRTC as sync source, its recommended to use GNSS Receiver with better holdover characteristics due to minimize the impact on cells during the GNSS failures. It is also a good practice to have a packet-based sync source as a backup (G.8275.1 [1] full timing support or G.8275.2 [3] partial timing support) so that in case of any GNSS errors, the O-RU can switchover to Packet based sync as usually the time to rectify or recover from the GNSS faults needs a site inspection which can run into multiple days and during this time the O-RU PLL might have drifted further which can affect the cells. + +![Figure B.3-1: Network based sync backup for O-RU. The diagram shows a T-GM connected to an O-DU. The O-DU is connected to two O-RUs, O-RU1 and O-RU2. O-RU1 is connected to a GNSS source. O-RU2 is also connected to a GNSS source, but the connection is marked with a red 'X', indicating a failure or loss of sync. Data flows are shown: CUS traffic from T-GM to O-RU1 and O-RU2, and PTP from O-RU1 to O-DU.](96c44df5802b31aa092779867b4066e2_img.jpg) + +``` + +graph TD + TGM[T-GM] <--> ODU[O-DU] + ODU -- "CUS traffic" --> ORU1[O-RU1] + ODU -- "CUS Traffic" --> ORU2[O-RU2] + ORU1 -- "PTP" --> ODU + ORU1 --> GNSS1[GNSS] + ORU2 --> GNSS2[GNSS] + style GNSS2 stroke-dasharray: 5 5, stroke:red + +``` + +Figure B.3-1: Network based sync backup for O-RU. The diagram shows a T-GM connected to an O-DU. The O-DU is connected to two O-RUs, O-RU1 and O-RU2. O-RU1 is connected to a GNSS source. O-RU2 is also connected to a GNSS source, but the connection is marked with a red 'X', indicating a failure or loss of sync. Data flows are shown: CUS traffic from T-GM to O-RU1 and O-RU2, and PTP from O-RU1 to O-DU. + +**Figure B.3-1: Network based sync backup for O-RU** + +4. O-DU connected to multiple O-RUs, its recommended to identify and isolate the O-RU which has the sync loss decouple this O-RU, detach the cells, and continue to operate with the other connected O-RUs which are synced/locked +5. It is recommended to have better holdover characteristics for O-DU for higher holdover durations than the connected O-RUs to serve all the connected O-RUs for the holdover durations. + +Note: All the recommendations described above are at high level for reference. For detailed recommendations, need refer CUS specification Chapter 9 [33]. + +# Annex C QoS Considerations for PTP packets + +To achieve high degree of accuracy of the synchronization clock recovered from PTP, important aspect of the overall solution is the precise time stamping of PTP packets. + +To achieve Class C requirements, physical layer time stamping must be implemented, since other time stamping methods, or PTP packets without timestamping at all, do not provide suitable accuracy. From the QoS perspective, PTP packets with physical layer time stamping do not require strict priority queueing to optimize packet's latency/jitter, since the queueing time is accounted by the physical layer time stamps. The only requirement is some QoS queue with guaranteed bandwidth, to avoid PTP packet drop during congestion events. + +As already discussed in sections 6.2.2 and 6.2.3 might happen, especially in mixed 3G/4G/5G deployments, that both ITU-T G.8275.1 [1] PTP profile (with hop-by-hop PTPoE sessions using physical layer timestamping for PTPoE packets) and ITU-T G.8275.2 [3] PTP profile (with multi-hop PTPoIP sessions) are used across the transport network. Depending on the transport network element capabilities, it can happen that the PTPoIP packets are not time-stamped (i.e., T-BC/T-TC function to timestamp PTPoIP packets is missing) on transit transport network elements. This is called PTP unaware node. In such case, PTP unaware nodes might considerably increase the latency/jitter of PTPoIP packets. Examples of possible deployments of Partial Timing Support and Assisted Partial Timing Support, with some transit routers being PTP unaware routers, are presented in Figure C-1, Figure C-2 and Figure C-3. + +![Figure C-1: Partial Timing Support deployment model. This diagram shows a network topology for PTP. It starts with a T-GM (G.8275.2) connected to a PTP unaware node. The connection is labeled PTPoIP. This is followed by a T-TC node, then a T-BC-P (G.8275.2) node, then another PTP unaware node, then a T-BC with IWF (G.8275.2 to G.8275.1) node, and finally a T-BC node connected to an O-RU. The connections between T-TC and T-BC-P, and between T-BC with IWF and T-BC, are labeled PTPoIP. The connections between T-BC with IWF and O-RU, and between T-BC and O-RU, are labeled PTPoE.](5f6cfa76fc953e91cf0d4fd81de116c8_img.jpg) + +Figure C-1: Partial Timing Support deployment model. This diagram shows a network topology for PTP. It starts with a T-GM (G.8275.2) connected to a PTP unaware node. The connection is labeled PTPoIP. This is followed by a T-TC node, then a T-BC-P (G.8275.2) node, then another PTP unaware node, then a T-BC with IWF (G.8275.2 to G.8275.1) node, and finally a T-BC node connected to an O-RU. The connections between T-TC and T-BC-P, and between T-BC with IWF and T-BC, are labeled PTPoIP. The connections between T-BC with IWF and O-RU, and between T-BC and O-RU, are labeled PTPoE. + +Figure C-1: Partial Timing Support deployment model + +![Figure C-2: Example 1 of Assisted Partial Timing Support deployment. This diagram shows a network topology where a T-GM (G.8275.2) is connected to three PTP unaware nodes in series, which are then connected to an O-RU. The connection between the T-GM and the first PTP unaware node is labeled PTPoIP. A PRTC (GNSS) node is connected to the O-RU, providing timing assistance.](7757aa533caba1806fef39a63ca3eb13_img.jpg) + +Figure C-2: Example 1 of Assisted Partial Timing Support deployment. This diagram shows a network topology where a T-GM (G.8275.2) is connected to three PTP unaware nodes in series, which are then connected to an O-RU. The connection between the T-GM and the first PTP unaware node is labeled PTPoIP. A PRTC (GNSS) node is connected to the O-RU, providing timing assistance. + +Figure C-2: Example 1 of Assisted Partial Timing Support deployment + +![Figure C-3: Example-2 of Assisted Partial Timing Support deployment. This diagram shows a network topology similar to Figure C-1, but with a PRTC (GNSS) node connected to a T-BC-A (GNSS Assisted) node. The T-GM (G.8275.2) is connected to a PTP unaware node, then a T-TC node, then another PTP unaware node, then the T-BC-A (GNSS Assisted) node, then a T-BC node, then another T-BC node, and finally the O-RU. The connections between the T-GM and the first PTP unaware node, and between the T-TC and T-BC-A, are labeled PTPoIP. The connections between the T-BC-A and the first T-BC, and between the second T-BC and the O-RU, are labeled PTPoE.](5a156e78c5cb095d4b7bf4f1702f1bc7_img.jpg) + +Figure C-3: Example-2 of Assisted Partial Timing Support deployment. This diagram shows a network topology similar to Figure C-1, but with a PRTC (GNSS) node connected to a T-BC-A (GNSS Assisted) node. The T-GM (G.8275.2) is connected to a PTP unaware node, then a T-TC node, then another PTP unaware node, then the T-BC-A (GNSS Assisted) node, then a T-BC node, then another T-BC node, and finally the O-RU. The connections between the T-GM and the first PTP unaware node, and between the T-TC and T-BC-A, are labeled PTPoIP. The connections between the T-BC-A and the first T-BC, and between the second T-BC and the O-RU, are labeled PTPoE. + +Figure C-3: Example-2 of Assisted Partial Timing Support deployment + +Therefore, if PTP unaware nodes are present in the transport network, two network design aspects must be taken into consideration: + +- devices sourcing PTPoIP packets (i.e., T-GMs or T-BCs) MUST consistently mark these packets network-wide agreed DSCP value +- PTP unaware nodes MUST match PTPoIP packets (based on agreed DSCP value) and apply appropriate QoS policies to minimize latency/PDV for PTPoIP packets not time stamped on transit nodes. + +Table C-1 contains a list of typical flows that can be observed in the multiclass transport network used to transport 5G flows as well. When recommending appropriate QoS policies for PTP, overall QoS policies for all flows must be taken into consideration. + +| Traffic type | Packet size<br>(order of magnitude) | Per-hop latency<br>(order of magnitude) <sup>1)</sup> | Per-hop PDV<br>(order of magnitude) <sup>1)</sup> | +|------------------------------------------------------------------------------------------------------------------|-------------------------------------|-------------------------------------------------------|---------------------------------------------------| +| PTP (unaware mode) <sup>2)</sup> | ~100 bytes | constant average<br>(equal to/from T-BC) | ~0.5 $\mu$ s <sup>3)</sup> | +| CPRI (RoE) | ~1500 bytes | ~1-5 $\mu$ s | ~1-5 $\mu$ s | +| eCPRI CU-P | ~1500 bytes | ~1-5 $\mu$ s | ~1-5 $\mu$ s | +| OAM with aggressive timers | ~100 bytes | ~1 ms | ~1 ms | +| latency sensitive U-plane<br>and business traffic | IMIX | ~1 ms | ~1 ms | +| Network Control: OAM<br>with relaxed timers, IGP,<br>BGP, LDP, RSVP, PTP<br>aware mode (T-TC/T-BC) <sup>4)</sup> | variable | ~5 ms | ~1-3 ms | +| Other traffic types | variable | ~10-50 ms | ~5-25 ms | + +**Table C-1: Different flows per-hop latency/PDV (order of magnitude)** + +Note 1: Exact per-hop requirements depend on the overall network budget, number of hops, budget allocated to fibers, etc. ... + +Note 2: PTP unaware mode i.e., transiting router that do not support T-TC/T-BC function, strict-priority queue is required to minimize jitter (actual latency value is not relevant, but its average should be constant). Minimizing the latency via strict-priority queue minimizes jitter as well. + +**Reco: This ORAN specification does not recommend PTP unaware mode of network deployment** + +Note 3: Max|TE| accumulated across the network must be $\leq 1.1 \mu$ s. + +Note 4: T-BC/T-TC with physical layer time stamping, guaranteed bandwidth queue is good enough, strict-priority queue is not required, since jitter/PDV will be accounted by physical layer timestamps in PTP packet. Also, latency value is not relevant, but average latency should be constant. QoS should ensure that PTP packets are not dropped during congestion, and guaranteed bandwidth queue is sufficient for that. + +There are variety of hardware support for QoS, depending on the hardware. It is out of scope for this document to discuss all the various QoS models supported by different hardware platforms of transport network elements. More detailed discussion about QoS is provided in [32]. From the PTP point of view, however, two major QoS models are worth to mention. + +![Figure C-4: QoS model with single expedited forwarding (strict priority) queue. The diagram shows a multi-queue architecture with an EF queue at the top and several AF queues below. The EF queue is labeled 'Very high weight to ensure frequent enqueueing in order to avoid queue congestion, and thus to keep queue latency to minimum'. The AF queues are labeled with various traffic types: CPRI (RoE), eCPRI CU-P, PTP (unaware mode); OAM with aggressive timers, latency sensitive U-plane and business traffic; Network Control: OAM with relaxed timers, IGP, BGP, LDP, RSVP, eCPRI S-P, PTP (T-TC/T-BC); Guaranteed bandwidth U-plane and business traffic; Other guaranteed bandwidth traffic (e.g. eCPRI M-P, other management); spare; spare; and Other best effort (may be guaranteed). Each queue has a 'Weight' and a 'PIR' (Peak Information Rate) field. The EF queue has a 'PIR mandatory' label, while the AF queues have a 'PIR optional' label. A 'Scheduler parameters' label points to the 'Weight' and 'PIR' fields. A 'Port' label with an arrow points to the output of the queues. A note at the bottom states 'Queue buffer size aligned to maximum latency requirements'.](56b324032a4ed7961728ddef14f5c173_img.jpg) + +Figure C-4: QoS model with single expedited forwarding (strict priority) queue. The diagram shows a multi-queue architecture with an EF queue at the top and several AF queues below. The EF queue is labeled 'Very high weight to ensure frequent enqueueing in order to avoid queue congestion, and thus to keep queue latency to minimum'. The AF queues are labeled with various traffic types: CPRI (RoE), eCPRI CU-P, PTP (unaware mode); OAM with aggressive timers, latency sensitive U-plane and business traffic; Network Control: OAM with relaxed timers, IGP, BGP, LDP, RSVP, eCPRI S-P, PTP (T-TC/T-BC); Guaranteed bandwidth U-plane and business traffic; Other guaranteed bandwidth traffic (e.g. eCPRI M-P, other management); spare; spare; and Other best effort (may be guaranteed). Each queue has a 'Weight' and a 'PIR' (Peak Information Rate) field. The EF queue has a 'PIR mandatory' label, while the AF queues have a 'PIR optional' label. A 'Scheduler parameters' label points to the 'Weight' and 'PIR' fields. A 'Port' label with an arrow points to the output of the queues. A note at the bottom states 'Queue buffer size aligned to maximum latency requirements'. + +**Figure C-4: QoS model with single expedited forwarding (strict priority) queue** + +Figure C-4 outlines the QoS model with single expedited forwarding (strict priority) queue. In this hardware model, all flows with ultra-high latency/PDV sensitivity (PTP unaware mode, CPRI/RoE, eCPRI CU-P) must be placed in this EF queue, while other flows should be distributed among remaining AF (assured forwarding) queues. AF queue used for flows with high (but not ultra-high) latency/PDV sensitivity (OAM with aggressive timers, latency sensitive U-plane and business traffic) should be parametrized with relatively high weight used in WFQ/WRR/WDRR/MDRR (Weighted Fair Queueing, Weighted Round Robin, Weighted Deficit Round Robin, Modified Deficit Round Robin) scheduling algorithms, so that this queue is serviced very frequently, to avoid queue congestion and to minimize latency/PDV. + +![](480d140fb2abe9e4c3f482132c90c979_img.jpg) + +Very high weight to ensure frequent enqueueing in order to avoid queue congestion, and thus to keep queue latency to minimum + +Scheduler parameters + +| Queue Type | Queue Label | Scheduling | Weight | PIR | +|-------------------------------------------------------------------------------------------|-------------|-----------------------------|--------|---------------| +| PTP (unaware mode) | EF1 | Priority Scheduling | | PIR | +| CPRI (RoE) | EF2 | | | PIR | +| eCPRI CU-P | EF3 | | | PIR | +| OAM with aggressive timers, latency sensitive U-plane and business traffic | AF | WFQ/RRR/DRR/MDRR Scheduling | Weight | PIR mandatory | +| Network Control: OAM with relaxed timers, IGP, BGP, LDP, RSVP, eCPRI S-P, PTP (T-TC/T-BC) | AF | | Weight | PIR | +| Guaranteed bandwidth U-plane and business traffic | AF | | Weight | PIR optional | +| Other guaranteed bandwidth traffic (e.g. eCPRI M-P, other management) | AF | | Weight | PIR | +| Other best effort (may be guaranteed) | AF | | Weight | PIR | + +Queue buffer size aligned to maximum latency requirements + +Port + +**Figure C-5: QoS model with multiple prioritized expedited forwarding queues, and CPRI/eCPRI separation** + +![](12a6cda66de3e325093e73fa00e21e75_img.jpg) + +Scheduler parameters + +| Queue Type | Queue Label | Scheduling | Weight | PIR | +|-------------------------------------------------------------------------------------------|-------------|-----------------------------|--------|---------------| +| PTP (unaware mode) | | Priority Scheduling | | PIR | +| CPRI (RoE), eCPRI CU-P | | | | PIR mandatory | +| OAM with aggressive timers, latency sensitive U-plane and business traffic | | | | PIR | +| Network Control: OAM with relaxed timers, IGP, BGP, LDP, RSVP, eCPRI S-P, PTP (T-TC/T-BC) | | WFQ/RRR/DRR/MDRR Scheduling | Weight | PIR | +| Guaranteed bandwidth U-plane and business traffic | | | Weight | PIR optional | +| Other guaranteed bandwidth traffic (e.g. eCPRI M-P, other management) | | | Weight | PIR | +| spare | | | Weight | PIR | +| Other best effort (may be guaranteed) | | | Weight | PIR | + +Queue buffer size aligned to maximum latency requirements + +Port + +**Figure C-6: QoS model with multiple prioritized expedited forwarding queues, and CPRI/eCPRI sharing the queue** + +Figure C-5 and Figure C-6 outline a recommended queue assignment on hardware platforms supporting multiple expedited forwarding queues, dequeued in strict priority order. Difference between two options is CPRI/eCPRI placement: + +- in separate queues, prioritizing CPRI queue over eCPRI queue (Figure C-5) +- in common queue (Figure C-6) + +1 +2 +3 +4 +5 +6 +7 + +In both cases, it is recommended to place PTP packets in unaware mode in the highest priority queue, to minimize the PDV of these packets to the highest possible degree. Putting these packets above CPRI(RoE) or eCPRI has only minimal influence on CPRI/eCPRI packets PDV, since PTP packets are very small (~100 bytes). For example, serialization delay of such small packet on 10 GE interface is only 80 ns, so PDV factor contributing to CPRI/eCPRI PDV is very small as well and can be easily handled by the CPRI/eCPRI reassembly functions. + +# --- Annex D R-PHY (DOCSIS over Ethernet) + +Will be covered in the future version of this specification + +# Annex E Synchronization over TDM PON + +## E.1 Short introduction to TDM PON + +A TDM PON system is composed of an Optical Liner Termination (OLT) with one or more network ports and one or more PON ports, the point-to-multipoint optical distribution networks (ODNs) terminated by the OLT, and a set of Optical Network Units (ONUs) on each ODN. Each ONU then provides network connectivity to one or more “user” devices connected to it. In the case of Mobile X-haul such devices are gNBs, O-CUs, O-DUs and/or O-RUs. + +TDM PONs are characterized by the shared medium nature of the ODN connecting multiple ONUs to a single OLT port. The common bandwidth is shared in TDM fashion in downstream (DS) and TDMA fashion in upstream (US), with a WDM separation between downstream and upstream signals for full duplex operation. For upstream the TDMA is performed by means of a Dynamic Bandwidth Assignment (DBA) algorithm in the OLT that controls when each ONU can send a burst of data, so that bursts from different ONUs are interleaved at the OLT receiver without overlaps. In downstream the TDM is done by each ONU only selecting the packets that are destined to itself. + +![Figure E-1: TDM PON system diagram. The diagram illustrates the architecture of a TDM PON system. At the top, three sub-diagrams show: 1. Upstream multiplexing: access and selection by TDMA, showing three input streams (1, 2, 3) being multiplexed. 2. Downstream multiplexing: selection by TDM, showing a single input stream being split into three output streams (1, 2, 3). 3. Upstream / Downstream duplex: Channel Pair = λ_up + λ_down, separation by WDM, showing two separate channels (Down and Up) with WDM separation. The main diagram shows a PON OLT connected to a Mobile Core and Residential / Business Edge & aggregation. The OLT has multiple ports (Port A, Port B, Port ...) connected to a feeder. The feeder is connected to a 1:N passive optical splitter(s) within the ODN (Optical Distribution Network). The ODN class determines reach & split ratio combination. The ODN is connected to multiple ONUs (ONU 1, ONU 2, ONU 3, ONU ..., ONU N). The ONUs are connected to various user devices (laptops, smartphones, etc.).](f89044650a54f3649e9067b8c3fcbd60_img.jpg) + +Figure E-1: TDM PON system diagram. The diagram illustrates the architecture of a TDM PON system. At the top, three sub-diagrams show: 1. Upstream multiplexing: access and selection by TDMA, showing three input streams (1, 2, 3) being multiplexed. 2. Downstream multiplexing: selection by TDM, showing a single input stream being split into three output streams (1, 2, 3). 3. Upstream / Downstream duplex: Channel Pair = λ\_up + λ\_down, separation by WDM, showing two separate channels (Down and Up) with WDM separation. The main diagram shows a PON OLT connected to a Mobile Core and Residential / Business Edge & aggregation. The OLT has multiple ports (Port A, Port B, Port ...) connected to a feeder. The feeder is connected to a 1:N passive optical splitter(s) within the ODN (Optical Distribution Network). The ODN class determines reach & split ratio combination. The ODN is connected to multiple ONUs (ONU 1, ONU 2, ONU 3, ONU ..., ONU N). The ONUs are connected to various user devices (laptops, smartphones, etc.). + +**Figure E-1: TDM PON system** + +The latency for data transport is inherently asymmetrical in TDM PON; + +- DS : latency by buffering in the OLT, FEC over PON, serialization of control words at line rate, fiber propagation time, queuing & scheduling in ONU +- US: latency by TDMA in ONU (scheduling done by DBA in OLT), FEC over PON, serialization of control words at line rate, fiber propagation time, buffering in OLT + +The delay discrepancy between US and DS can be large and this means that PTP cannot be used across a TDM PON. The PON interface uses its own MAC encapsulation (over which Ethernet-based packets are transported transparently), meaning that plain Sync-E as such is not readily available at the ONU PON interface. Therefore, TDM PON systems have built in alternative methods for frequency and time synchronization. + +According to [1], a medium-specific access section can still act as a link in the synchronization chain by means of a pair of converters between PTP and the medium, also known as Inter-Working Functions IWF. When mapping this on a TDM PON system, the ODN is the access medium, the Transport Protocol Specific + +Transmission Convergence (TPS-TC) functionality is part of the IWF in the OLT and the ONU, and the PTP timeTransmitter and timeReceiver (in respectively ONU and OLT) represent the other part of their IWF, see Figure E-2. + +![Figure E-2: G.8271 Hypothetical Reference Model (HRM). This diagram illustrates the synchronization architecture across a network. At the top, a 'Network time reference (e.g., GNSS engine)' feeds into a 'PRTC' (Primary reference time clock). This PRTC is connected to a 'Packet master clock' (R1), which is part of a 'Packet network' (R2.0). The network continues through a 'Packet slave clock' (R3) to an 'End application time clock' (R4, R5). Below the network, a 'Transport section' (R2.1) connects the network to an 'Access section'. The 'Access section' contains a 'PTP-Medium IWF', an 'Access medium', and a 'Medium-PTP IWF'. A legend indicates that solid lines represent 'Physical timing signal (for phase and/or time synchronization)' and dashed lines represent 'Packet timing signal'. The diagram is labeled 'G.8271-Y.1366(16)_F05'.](c77ad995a5589a6c8a2757c4c42d1c77_img.jpg) + +Figure E-2: G.8271 Hypothetical Reference Model (HRM). This diagram illustrates the synchronization architecture across a network. At the top, a 'Network time reference (e.g., GNSS engine)' feeds into a 'PRTC' (Primary reference time clock). This PRTC is connected to a 'Packet master clock' (R1), which is part of a 'Packet network' (R2.0). The network continues through a 'Packet slave clock' (R3) to an 'End application time clock' (R4, R5). Below the network, a 'Transport section' (R2.1) connects the network to an 'Access section'. The 'Access section' contains a 'PTP-Medium IWF', an 'Access medium', and a 'Medium-PTP IWF'. A legend indicates that solid lines represent 'Physical timing signal (for phase and/or time synchronization)' and dashed lines represent 'Packet timing signal'. The diagram is labeled 'G.8271-Y.1366(16)\_F05'. + +**Figure E-2: G.8271 Hypothetical Reference Model (HRM)** +(OLT on left, ONU on right) + +![Figure E-3: PON as link in the sync chain (example for D-RAN from G.9807.1). This diagram shows the synchronization chain in a PON system. At the top, a box defines the 'PON system (OLT + ODN + ONUs)', with 'TPS-TC (Transport Protocol Specific Transmission Convergence)' and 'ODN (Optical Distribution Network) = end-end optical connection'. The main part of the diagram shows a 'Grandmaster clock (Master)' connected to an 'RNC' via 'IEEE 1588 and SyncE' over an 'ETH' link. The RNC is connected to a 'Packet network', which is connected to an 'OLT' (Slave) via 'IEEE 1588 and SyncE' over an 'ETH' link. The OLT is connected to four 'ONU' (Master) units via 'XGS-PON'. Each ONU is connected to a 'Slave Node B' via 'IEEE 1588 and SyncE' over an 'ETH' link. The OLT and ONUs are labeled 'ITU-T G.9807.1 Annex C'. The diagram is labeled 'G.9807.1(16)_FA.V.2a'.](c378a3354e01666f4949dd2c33d39cd1_img.jpg) + +Figure E-3: PON as link in the sync chain (example for D-RAN from G.9807.1). This diagram shows the synchronization chain in a PON system. At the top, a box defines the 'PON system (OLT + ODN + ONUs)', with 'TPS-TC (Transport Protocol Specific Transmission Convergence)' and 'ODN (Optical Distribution Network) = end-end optical connection'. The main part of the diagram shows a 'Grandmaster clock (Master)' connected to an 'RNC' via 'IEEE 1588 and SyncE' over an 'ETH' link. The RNC is connected to a 'Packet network', which is connected to an 'OLT' (Slave) via 'IEEE 1588 and SyncE' over an 'ETH' link. The OLT is connected to four 'ONU' (Master) units via 'XGS-PON'. Each ONU is connected to a 'Slave Node B' via 'IEEE 1588 and SyncE' over an 'ETH' link. The OLT and ONUs are labeled 'ITU-T G.9807.1 Annex C'. The diagram is labeled 'G.9807.1(16)\_FA.V.2a'. + +**Figure E-3: PON as link in the sync chain (example for D-RAN from G.9807.1)** +(OLT on right, ONU on left) + +PTP is terminated in the OLT (timeReceiver clock). The time synchronization is carried over the PON medium by TPS-TC (more details in section E3). PTP is regenerated in each ONU (timeTransmitter clock) on its UNIs towards the end device (example is an O-RU). + +The PON system functionally acts as one (distributed) T-BC in the sync chain. In terms of performance, it can be modelled as pair of T-BCs of the same class. + +Note that this TPS-TC approach is completely independent from latency that regular traffic experiences across the PON system, so its accuracy is not linked to any QoS or traffic load dependency. The TDM PON system supports the hybrid model (PTP + Sync-E/eSyncE). + +## E.2 Specifics with TDM PON (compared to point-point links) for frequency synchronization + +In TDM PON systems there is a continuous downstream bitstream, whether it is real traffic or filling-in dummy traffic. Hence there is a continuous availability of frame structures and bit transitions. + +For ITU TDM PONs, frequency synchronization is done based on the precise framing structure (125 $\mu$ s) of the physical medium. The OLT terminates Sync-E or eSyncE from the network, uses it for its internal clock generating the frame structure. The ONU derives its clock frequency from the 8kHz frame repetition rate and uses it to support Sync-E or eSyncE on its user interfaces. Basically, the ONU PLL is controlled by the OLT clock which is synchronized by Sync-E. + +## E.3 Specifics with TDM PON (compared to point-point links) for time synchronization + +### E.3.1 Different use cases and related requirements + +This follows the use cases as described in the section 6.3.3 of this document and applies them to the use of TDM PON as access technology. The relevant use cases are: + +- LLS-C2: The O-DUs are connected to the T-GM and the O-DUs relay synchronization towards the O-RUs (across the PON access). +- LLS-C3: The O-DUs are connected to the T-GM and the O-RUs are connected (across the PON access) to the T-GM. +- LLS-C4: This may be achieved with a TDM PON access system, but it is not dependent on the TDM PON performance. Therefore, it is not further discussed in this document. + +The following figures indicate the requirements that a use case would put on the TDM PON system. The requirements from T-GM to O-RU for TDD are indicated in red squares, the requirements for coordination between O-RUs are indicated in purple squares. + +Section E.3.2 then reviews which of these requirements can be met by the capabilities of TDM PON systems. + +#### Distributed RAN (D-RAN): + +In D-RAN context only the end-end TDD requirement of $\pm 1500\text{ns}$ is to be accounted for (equivalent to $\pm 1100\text{ns}$ up to O-DU input as per scenario (a) in [1] table V.1). Depending on the number of T-BCs or T-TCs in the chain, a part of that budget is available to the TDM PON system. + +![Figure E-4: Sync requirements in D-RAN (backhaul) with TDM PON in access. The diagram illustrates the synchronization paths and timing requirements for a D-RAN architecture. It shows a PRTC/ePRTC T-GM connected to T-BCs/T-TCs, which are intermediate transport nodes. These nodes connect to OLTs (Optical Line Terminals) within a TDM PON system. The OLTs connect to ONUs (Optical Network Units), which then connect to gNBs (Next-Generation Base Stations) and O-DUs/O-CUs (Open Distributed Units/Open Core Units). The diagram highlights the PTP/SyncE path (orange dashed arrows) and the TPS-TC path (purple dashed arrows). Timing requirements are indicated at the bottom: ±1100ns for the path up to the O-DU input and ±1500ns for the total end-end path. The position of the PON system is marked with a dashed blue box.](590112391ce962a773c1bf3abfff6663_img.jpg) + +Figure E-4: Sync requirements in D-RAN (backhaul) with TDM PON in access. The diagram illustrates the synchronization paths and timing requirements for a D-RAN architecture. It shows a PRTC/ePRTC T-GM connected to T-BCs/T-TCs, which are intermediate transport nodes. These nodes connect to OLTs (Optical Line Terminals) within a TDM PON system. The OLTs connect to ONUs (Optical Network Units), which then connect to gNBs (Next-Generation Base Stations) and O-DUs/O-CUs (Open Distributed Units/Open Core Units). The diagram highlights the PTP/SyncE path (orange dashed arrows) and the TPS-TC path (purple dashed arrows). Timing requirements are indicated at the bottom: ±1100ns for the path up to the O-DU input and ±1500ns for the total end-end path. The position of the PON system is marked with a dashed blue box. + +**Figure E-4: Sync requirements in D-RAN (backhaul) with TDM PON in access** + +#### Virtual RAN (V-RAN): + +The requirements in V-RAN context are equivalent to the D-RAN context. + +![Figure E-5: Sync requirements in V-RAN (backhaul) with TDM PON in access. This diagram is similar to Figure E-4, showing the synchronization paths and timing requirements for a V-RAN architecture. It includes the PRTC/ePRTC T-GM, T-BCs/T-TCs, intermediate transport nodes, OLTs, ONUs, gNBs, and O-DUs/O-CUs. The PTP/SyncE path (orange dashed arrows) and the TPS-TC path (purple dashed arrows) are highlighted. The timing requirements are the same: ±1100ns up to the O-DU input and ±1500ns for the total end-end path. The position of the PON system is marked with a dashed blue box.](a2c3f85d050237f99d6765c6defe50fd_img.jpg) + +Figure E-5: Sync requirements in V-RAN (backhaul) with TDM PON in access. This diagram is similar to Figure E-4, showing the synchronization paths and timing requirements for a V-RAN architecture. It includes the PRTC/ePRTC T-GM, T-BCs/T-TCs, intermediate transport nodes, OLTs, ONUs, gNBs, and O-DUs/O-CUs. The PTP/SyncE path (orange dashed arrows) and the TPS-TC path (purple dashed arrows) are highlighted. The timing requirements are the same: ±1100ns up to the O-DU input and ±1500ns for the total end-end path. The position of the PON system is marked with a dashed blue box. + +1 + +**Figure E-5: Sync requirements in VRAN (F1 Midhaul) with TDM PON in access** + +#### Cloud RAN (C-RAN) + +For LLS fronthaul (C-RAN) the requirements are based on 1) same TDD requirement between T-GM and O-RU as V-RAN and D-RAN, and 2) coordination between the O-RUs mutually, resulting in meeting a given TAE category: + +- Category C: max TAE between O-RUs = $\pm 3000\text{ns}$ : +Applies to all O-RUs in the network +- Category B: max TAE between O-RUs = $\pm 260\text{ns}$ : +Applies to clusters of Regular O-RUs with FR1 or FR2, and to clusters of Enhanced O-RUs with FR1 or FR2 +- Category A: TAE between O-RUs = $\pm 130\text{ns}$ : +Applies only to cluster of co-located Enhanced O-RUs with FR2 + +The TAE must then be applied between the O-RUs connected to same T-BC in the network. There are multiple possible positions of the common clock, depending on which PON ODN (or PON ODNs) are subtending the different O-RUs. + +#### Different config topologies: + +- LLS-C2 + +![Figure E-6: Sync requirements in C-RAN (fronthaul) LLS-C2 with TDM PON in access. The diagram illustrates the synchronization architecture for LLS-C2. It shows a T-GM (T-BCs, T-TCs) connected to O-DUs, which are connected to intermediate transport nodes (T-BCs, T-TCs). These nodes connect to OLTs (PHY + OAM) which are connected to O-RUs (Cluster enhanced O-RUs and Cluster regular O-RUs). The diagram shows the PTP/Sync path and the PTP/Sync timeReceiver path. It also shows the TAE requirements for different categories: Cat C: 1500ns - |TE|O-RU, Cat B: ±95ns (enhanced O-RU) or ±50ns (basic), and Cat A: ±30ns (enhanced O-RU). The diagram includes a timeline at the bottom showing TDD requirements: ±1100ns, ±1325ns, ±1500ns, ±175ns, and ±140ns / ±95ns. The diagram also shows the position of the PON system and the nearest common T-BC options.](e32c338d1ab875c9e451bca2a8e99e50_img.jpg) + +Figure E-6: Sync requirements in C-RAN (fronthaul) LLS-C2 with TDM PON in access. The diagram illustrates the synchronization architecture for LLS-C2. It shows a T-GM (T-BCs, T-TCs) connected to O-DUs, which are connected to intermediate transport nodes (T-BCs, T-TCs). These nodes connect to OLTs (PHY + OAM) which are connected to O-RUs (Cluster enhanced O-RUs and Cluster regular O-RUs). The diagram shows the PTP/Sync path and the PTP/Sync timeReceiver path. It also shows the TAE requirements for different categories: Cat C: 1500ns - |TE|O-RU, Cat B: ±95ns (enhanced O-RU) or ±50ns (basic), and Cat A: ±30ns (enhanced O-RU). The diagram includes a timeline at the bottom showing TDD requirements: ±1100ns, ±1325ns, ±1500ns, ±175ns, and ±140ns / ±95ns. The diagram also shows the position of the PON system and the nearest common T-BC options. + +Figure E-6: Sync requirements in C-RAN (fronthaul) LLS-C2 with TDM PON in access + +#### TDD requirements: + +Table 9-3 in [33] states a budget of $\pm 1325\text{ns}$ for the TE between T-GM and O-DU UNI. The remaining portion for TE between O-DU UNI and air interface is $\pm 175\text{ns}$ . Depending on the O-RU clock type (enhanced or regular), this translates into respectively $\pm 140\text{ns}$ or $\pm 95\text{ns}$ between the O-DU UNI and the O-RU network port. Depending on the amount of intermediate transport nodes between the O-DU and the OLT, a portion of that is available for the TDM PON system. + +#### Sync requirements for category A and B: + +The options (as indicated in figure E-6) for the nearest common T-BC are: + +- Option-A: O-DU output: when O-RUs that are managed by the same O-DU are on different OLTs and different intermediate nodes +- Option-B1: T-BC output: when O-RUs are on different OLTs but share at least one intermediate transport node (If the T-BC is the last in the chain, this point is equivalent to the OLT input). +- Option-B2: Internal point in OLT: when O-RUs are on same OLT, but different PON cards +- Option-B3: (closer) internal point in OLT: when O-RUs are on same PON port, or on different PON ports on the same PON card + +##### LLS-C3 Option A: + +![Figure E-7: Sync requirements in C-RAN (fronthaul) LLS-C3 Option A with TDM PON in access. The diagram illustrates the network architecture and timing requirements. It shows a central 'Intermediate transport nodes' block containing 'T-BCs T-TCs'. This block is connected to 'O-DU' blocks on the left and 'PRTC/ePRTC T-GM' blocks on the right. The 'PRTC/ePRTC T-GM' blocks are connected to 'OLT' blocks, which are further connected to 'ONU' blocks. The 'ONU' blocks are connected to 'O-RU' blocks, which are grouped into 'Cluster enhanced O-RUs' and 'Cluster regular O-RUs'. The diagram also shows 'PHY + OAM' blocks and 'TT' blocks. Timing requirements are indicated by arrows and boxes: 'TDD requirements' (±1500ns), 'Sub-option (i)' (±1100ns), 'Sub-option (ii)' (±1100ns), 'Sub-option (iii)' (±1100ns), 'Sub-option (iv)' (±1500ns), and 'Cat requirements not considered in this document'. A table lists the requirements for different categories: Cat C: 1500ns - |TE|_O-DU, Cat B: ±95ns (enhanced O-RU) or ±50ns (basic), Cat A: ±30ns (enhanced O-RU).](6671330d212558e1cbcd34005b2b7ff6_img.jpg) + +Figure E-7: Sync requirements in C-RAN (fronthaul) LLS-C3 Option A with TDM PON in access. The diagram illustrates the network architecture and timing requirements. It shows a central 'Intermediate transport nodes' block containing 'T-BCs T-TCs'. This block is connected to 'O-DU' blocks on the left and 'PRTC/ePRTC T-GM' blocks on the right. The 'PRTC/ePRTC T-GM' blocks are connected to 'OLT' blocks, which are further connected to 'ONU' blocks. The 'ONU' blocks are connected to 'O-RU' blocks, which are grouped into 'Cluster enhanced O-RUs' and 'Cluster regular O-RUs'. The diagram also shows 'PHY + OAM' blocks and 'TT' blocks. Timing requirements are indicated by arrows and boxes: 'TDD requirements' (±1500ns), 'Sub-option (i)' (±1100ns), 'Sub-option (ii)' (±1100ns), 'Sub-option (iii)' (±1100ns), 'Sub-option (iv)' (±1500ns), and 'Cat requirements not considered in this document'. A table lists the requirements for different categories: Cat C: 1500ns - |TE|\_O-DU, Cat B: ±95ns (enhanced O-RU) or ±50ns (basic), Cat A: ±30ns (enhanced O-RU). + +**Figure E-7: Sync requirements in C-RAN (fronthaul) LLS-C3 Option A with TDM PON in access** + +#### TDD requirements: + +The budget between T-GM and O-RU network port is $\pm 1100\text{ns}$ . Depending on the number of T-BCs and/or T-TCs in the chain, a part of that budget is available to the TDM PON system. + +#### Sync requirements for category A and B: + +The options as indicated in figure E-7 for the nearest common T-BC are: + +- Option-i (T-GM): when O-RUs are on different OLTs and different intermediate nodes +- Option-ii (T-BC output): when O-RUs are on different OLTs but share at least one intermediate transport node (If the T-BC is the last in the chain, this ref point is equivalent to the OLT input). +- Option-iii (Internal point in OLT): when O-RUs are on same OLT, different PON cards +- Option-iv (internal point in OLT): when O-RUs are on same PON port, or on different PON ports on the same PON card + +##### LLS-C3 Option B: + +![Figure E-8: Sync requirements in C-RAN with LLS-C3 Option B and TDM PON in access. The diagram illustrates the network architecture and timing requirements. It shows a central 'Intermediate transport nodes' block containing 'T-BCs' and 'T-TCs'. This block is connected to 'O-DU' (Distributed Units) on the left and 'PRTC/ePRTC T-GM' (Central Units) at the top. The transport nodes connect to 'OLT' (Optical Line Terminals) which then connect to 'ONU' (Optical Network Units) and 'O-RU' (Radio Units). The 'Position of PON system' is shown with 'PHY + OAM' and 'PHY + OAM' blocks. The diagram also shows 'Cluster enhanced O-RUs' and 'Cluster regular O-RUs'. Timing requirements are indicated by red arrows: ±1500ns for TDD requirements, ±1100ns for the budget between T-GM and O-RU network port, and ±1500ns for the budget between T-GM and O-RU network port. The diagram also shows 'Cat C: ±1500ns - |TE|O-RU', 'Cat B: ±95ns (enhanced O-RU) or ±50ns (basic)', and 'Cat A: ±30ns (enhanced O-RU)'. A note states 'Cat requirements not considered in this document'.](0d70f70f013041141064446fe38ce4d7_img.jpg) + +Figure E-8: Sync requirements in C-RAN with LLS-C3 Option B and TDM PON in access. The diagram illustrates the network architecture and timing requirements. It shows a central 'Intermediate transport nodes' block containing 'T-BCs' and 'T-TCs'. This block is connected to 'O-DU' (Distributed Units) on the left and 'PRTC/ePRTC T-GM' (Central Units) at the top. The transport nodes connect to 'OLT' (Optical Line Terminals) which then connect to 'ONU' (Optical Network Units) and 'O-RU' (Radio Units). The 'Position of PON system' is shown with 'PHY + OAM' and 'PHY + OAM' blocks. The diagram also shows 'Cluster enhanced O-RUs' and 'Cluster regular O-RUs'. Timing requirements are indicated by red arrows: ±1500ns for TDD requirements, ±1100ns for the budget between T-GM and O-RU network port, and ±1500ns for the budget between T-GM and O-RU network port. The diagram also shows 'Cat C: ±1500ns - |TE|O-RU', 'Cat B: ±95ns (enhanced O-RU) or ±50ns (basic)', and 'Cat A: ±30ns (enhanced O-RU)'. A note states 'Cat requirements not considered in this document'. + +Figure E-8: Sync requirements in C-RAN with LLS-C3 Option B and TDM PON in access + +#### TDD requirements: + +The budget between T-GM and O-RU network port is $\pm 1100\text{ns}$ . Depending on the number of intermediate T-BCs and/or T-TCs in the chain, a part of that budget is available to the TDM PON system. + +#### Category A and B sync requirements: + +The options as indicated in figure E-8 to the nearest common T-BC are: + +- Option-i (T-BC output): when O-RUs are on different OLTs but share at least one intermediate transport node (If the T-BC is the last in the chain, this ref point is equivalent to the OLT input). +- Option-ii (internal point in OLT): when O-RUs are on same OLT, but different PON cards +- Option-iii (internal point in OLT): when O-RUs are on same PON port, or on different PON ports on the same PON card + +##### LLS-C3 Option C and D: + +#### TDD requirements: + +The budget between T-GM and O-RU network port is $\pm 1100\text{ns}$ . Depending on the number of T-BCs and/or T-TCs in the chain, a part of that budget is available to the TDM PON system. + +#### Category A and B Sync requirements: + +The options as indicated in figure E-9 to the nearest common T-BC are: + +- Option-i (common T-BC output): when O-RUs are on different OLTs but share at least one intermediate transport node +- Option-ii (T-BC output): when O-RUs are on different OLTs but share at least one intermediate transport node (If the T-BC is the last in the chain, this ref point is equivalent to the OLT input). +- Option-iii (internal point in OLT): when O-RUs are on same OLT, different PON cards +- Option-iv (internal point in OLT): when O-RUs are on same PON port, or on different PON ports on the same PON card + +![Figure E-9: Sync requirements in C-RAN with LLS-C3 Options C, D and TDM PON in access. The diagram illustrates the synchronization architecture for C-RAN with LLS-C3 Options C, D, and TDM PON in access. It shows the flow from the PRTC/ePRTC T-GM through T-BCs and T-TCs to O-DUs, then through intermediate transport nodes (T-BCs and T-TCs) to OLTs. The OLTs are connected to ONUs (PHY + OAM) which are further connected to O-RUs (Cluster enhanced O-RUs and Cluster regular O-RUs). The diagram includes various timing constraints and sub-options (i) through (iv) for different categories (Cat C, Cat B, Cat A). A table at the bottom right lists the requirements for different categories, noting that Cat requirements are not considered in this document.](84ab9508f9e978d2577ee3071c5b0b02_img.jpg) + +Nearest common T-BC sub-options: + +Sub-option (i) Sub-option (ii) Sub-option (iii) Sub-option (iv) + +Position of PON system + +Cluster enhanced O-RUs + +Cluster regular O-RUs + +Cat C: 1500ns - |TE|<sub>O-RU</sub> +Cat B: ±95ns (enhanced O-RU) or ±50ns (basic) +Cat A: ±30ns (enhanced O-RU) + +±1100ns ±1100ns ±1500ns + +±130-260ns ±260ns + +3000ns + +Cat requirements not considered in this document + +Figure E-9: Sync requirements in C-RAN with LLS-C3 Options C, D and TDM PON in access. The diagram illustrates the synchronization architecture for C-RAN with LLS-C3 Options C, D, and TDM PON in access. It shows the flow from the PRTC/ePRTC T-GM through T-BCs and T-TCs to O-DUs, then through intermediate transport nodes (T-BCs and T-TCs) to OLTs. The OLTs are connected to ONUs (PHY + OAM) which are further connected to O-RUs (Cluster enhanced O-RUs and Cluster regular O-RUs). The diagram includes various timing constraints and sub-options (i) through (iv) for different categories (Cat C, Cat B, Cat A). A table at the bottom right lists the requirements for different categories, noting that Cat requirements are not considered in this document. + +Figure E-9: Sync requirements in C-RAN with LLS-C3 Options C, D and TDM PON in access + +### E.3.2 TDM PON capabilities + +#### Mechanisms + +Synchronization over TDM PON is made possible by the fact that the system is inherently synchronized between the OLT and its ONUs. + +First, each ONU is detected and automatically “ranged”, whereby the OLT measures its distance and sets time equalization per ONU, to align on it on the US TDMA scheme. For this time alignment each ONU has access to a common (arbitrary) time reference with the OLT (ITU PON: D/S 125μs frame boundary). + +Then the correlation to ToD (received at the OLT by PTP from the network) is added; each ONU retrieves the absolute ToD for an association of a given event with a given timestamp. This association is communicated by the OLT to the ONU in a management message. In ITU PON the ToD (at a hypothetical ONU, at start of PON frame X) is communicated via OMCI to each ONU. + +#### Dependencies + +There are several factors that impact the Time Error (TE) across TDM PON system (OLT SNI – ONU UNI): + +- RTT estimation depends on speed of light, which depends on $n(\lambda)$ +- Variation on $\lambda$ : the PON WDM bands in US and DS depend on the PON technology +- Accuracy of PON time equalization of ONUs (correction measure to deal with ONU drifts) +- Knowledge of internal delays in OLT +- Knowledge of internal delays in ONU + +The Time Alignment Error (TAE) between two O-RU air interfaces when subtended over TDM PON depends on: + +- Location of the reference clock common to both O-RUs, which depends on the topology: + - Common PON card (same PON port or different PON ports): local card clock + - Common OLT node: local OLT clock + +- Different OLTs: first common node to which both OLTs are connected +- Accuracies of the (relevant part of the) TDM PON system (the TE between the common clock reference and ONU UNI) + +#### Capabilities of TDM PON systems + +TDM PON standards do not provide system-wide requirements (OLT SNI – ONU UNI) on time synchronization performance, but it is an active area of discussion. + +The built-in mechanisms for ToD distribution across a TDM PON medium (TPS-TC) are very accurate, in the order of 10ns for cTE: + +- ToD notifications in OAM messages have 1ns resolution +- Ranging accuracy can be in the order of several ns (below 5ns) +- Estimation of variations on $n(\lambda)$ over the known WDM bands and fiber type can bring precision of factors depending on $n(\lambda)$ down to below 5ns at 20km + +Ultimately, the full system performance (including dTE) is up to implementation of ONU and OLT. + +There is no standardized way yet to test/characterize TAE between multiple output ports of a system for all T-BC Class of clocks (ITU-T standards have defined only for Class-C T-BC, but TDM PON systems do not meet this accuracy). + +There are two ways to label a given performance of a system in function of its $\max|TE|$ between OLT SNI and ONU UNI: + +- Either it is equivalent to a single T-BC of a given class (refer [2] Table 7-1), +- or it is equivalent to what is expected from a pair of T-BCs of the same class (refer [2] Table V.1, or formula IV-13 in [8] (which has two extreme cases depending on the symmetry of $|dTE_L(t)|$ around cTE)). + +For example, for a TDM PON system that would meet $\max|TE|$ of 100ns, it would mean: + +- Compliance of full system to pair of Class A T-BCs ( $\max|TE|$ of 160ns as per [2] or 130 to 160ns as per [8]) +- Compliance of full system to pair of Class B T-BCs ( $\max|TE|$ of 100ns as per [2] or upper bound of 100ns as per [8] or single Class A T-BC (100ns) +- No compliance of full system to single Class B T-BC (interpreted as $\max|TE|$ of 70ns as per [2] or upper bound of 70ns as per [8]) +- No compliance of full system to pair of Class C T-BCs ( $\max|TE|$ of 45ns as per [2] , or upper bound of 35ns as per [8]) or single Class C T-BC ( $\max|TE|$ of 30ns) + +### E.3.3 Overview of TDM PON support use cases + +The “Required Budget” in Table E.3-1 represents the end-end $|TE|$ allowed for a given Category and a given O-RU type: + +- Cat C: 1500ns - $|TE|_{O-RU}$ +- Cat B with enhanced O-RUs: 95ns +- Cat B with regular O-RUs: 50ns +- Cat A with enhanced O-RUs: 30ns + +| Mobile X-haul use case with TDM PON | Category C | Category B with enhanced O-RU | Category B with regular O-RU | Category A with enhanced O-RU | +|-----------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------|------------------------------|-------------------------------| +| Pair of Class-A T-BC as per G.8273.2 (max $ TE $ = 160 ns) | No for LLS-C2 (required $\leq 140$ ns)<br>Yes, for LLS-C3 (note-1) | No | No | No | +| Pair of Class-A T-BCs as per ITU-T G.8271.1 with fully symmetrical case. (max $ TE $ = 130ns) | Yes, for all LLS-C3 options.<br>Yes, for LLS-C2 if cluster of enhanced O-RUs and no intermediate node (required $\leq 140$ ns) | No | No | No | +| Pair of Class-B T-BC as per G.8273.2 (max $ TE $ = 100ns) | Yes, for LLS-C2 (note-1)<br>Yes, for LLS-C3 (note-1) | Yes, for LLS-C2 if enhanced O-RUs connected to ports of same card of PON system<br><br>Yes, for LLS-C3 all options | No | No | + +**Table E.3-1: TDM PON use cases supported in fronthaul** + +Note 1: + +The PON system will consume part of the end-to-end budget. The performance of the PON system and the number of other intermediate nodes (if any and their class performance) between the T-GM and the O-RU will determine the synchronization category that can be supported. + +TDM PON systems that can meet max $|TE|$ of 100ns are suitable for Backhaul, Midhaul and Fronthaul category C deployments. TDM PON systems can be deployed in fronthaul category B application, provided the enhanced O-RUs in a cluster are connected to the same OLT or same PON card. + +TDM PON systems that can meet better than 100ns max $|TE|$ performance needed to support the other use cases. + +# --- Annex F Multi-TDD operator considerations + +Will be covered in the future version of this specification + +# Annex G Security Considerations + +Security in Xhaul networks and specifically in Fronthaul networks for sync plane is critical for the operation of the wireless network. Encryption, Authentication and/or Architectural redundancy models are different ways to secure and mitigate the security threats of the network. This chapter describes various models that can be exercised to secure the sync plane in the Xhaul networks. + +## G.1 Architectural Redundancy Models + +The Authentication, Integrity protection and/or Encryption of the PTP control (events and general) packets do not always address the performance degradation introduced by some rogue nodes in the middle. The Architectural redundancy models in this section describes how to effectively detect and mitigate the performance degradation and other attacks. + +### G.1.1 Network model with no sync redundancy + +![Figure G-1: Network model with no sync redundancy. The diagram shows a linear topology of nodes: O-RU, CSR, HSR, and GM. Blue arrows indicate the data flow from GM to O-RU. A red 'Attack' label with three arrows points to the connections between CSR and HSR, indicating a potential attack point.](0b85f4e9f9f6acd929757123f76ab5ee_img.jpg) + +Figure G-1: Network model with no sync redundancy. The diagram shows a linear topology of nodes: O-RU, CSR, HSR, and GM. Blue arrows indicate the data flow from GM to O-RU. A red 'Attack' label with three arrows points to the connections between CSR and HSR, indicating a potential attack point. + +Figure G-1 + +- The topology shown in Figure G-1 does not have sync network redundancy for the transport network elements (CSR and HSR nodes). +- Any attack on CSR, HSR or the points between GM to O-RU interconnects can impact the sync recovery at O-RU. +- Sync network without redundancy is difficult to detect and mitigate the performance degradation attack. + +### G.1.2 Network model with sync redundancy + +![Figure G-2: Network model with sync redundancy. The diagram shows a redundant topology with two parallel paths. The top path consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom path consists of O-RU-2, CSR-2, HSR-2, and GM-2. Blue arrows show the primary data flow from GM-1 to O-RU-1 and GM-2 to O-RU-2. Green arrows show cross-connections between the two paths, providing redundancy. A red 'Attack' label with three arrows points to the connections between CSR-1 and HSR-1, indicating a potential attack point.](73cb0e3a0592c015f3b5ab1409bdb473_img.jpg) + +Figure G-2: Network model with sync redundancy. The diagram shows a redundant topology with two parallel paths. The top path consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom path consists of O-RU-2, CSR-2, HSR-2, and GM-2. Blue arrows show the primary data flow from GM-1 to O-RU-1 and GM-2 to O-RU-2. Green arrows show cross-connections between the two paths, providing redundancy. A red 'Attack' label with three arrows points to the connections between CSR-1 and HSR-1, indicating a potential attack point. + +Figure G-2 + +- The topology shown in Figure G-2, redundant sync paths are exercised. Every node in the chain from GM to O-RU has more than one (two) sync paths, green and blue color respectively. +- Attack on any node or insertion of a rogue node in blue path can be mitigated with green path. +- The HSR, CSR and O-RU can exercise the passive port monitoring feature described in Annex-G of ITU-T G.8275.1 profile [1] -" Monitoring PTP timeTransmitter port using PTP passive port" to effectively detect any change in performance between active timeReceiver port and alternate passive port. +- Monitoring of the active timeTransmitter using passive port does not automatically trigger the A-BTCA algorithm to switchover rather it helps to detect the time/phase change between these two ports. The network operator can monitor the changes and take necessary action as needed to mitigate the attack. + +Note: With 1+1 resiliency model (as shown in figure G-2), it is only possible to detect the difference of the time between the passive and active PTP ports. It is not possible to predictably determine which clock/time source is correct. It is critical to have more than 2 links/PTP ports to detect the bad or rogue time source. + +### G.1.3 Architecture model where O-RUs with single network interface + +![Figure G-3: Architecture model where O-RUs have a single network interface. The diagram shows two rows of nodes. The top row consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom row consists of O-RU-2, CSR-2, HSR-2, and GM-2. Red arrows labeled 'Attack' point to CSR-1, HSR-1, and GM-1. Blue arrows show a path from GM-1 to CSR-1 to O-RU-1, and from GM-2 to CSR-2 to O-RU-2. Green arrows show a path from GM-1 to HSR-1 to CSR-2 to O-RU-2, and from GM-2 to HSR-2 to CSR-1 to O-RU-1. Both O-RU-1 and O-RU-2 are connected to GNSS antennas.](555337ebeaa90be0ff36d77cd6d00bd6_img.jpg) + +Figure G-3: Architecture model where O-RUs have a single network interface. The diagram shows two rows of nodes. The top row consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom row consists of O-RU-2, CSR-2, HSR-2, and GM-2. Red arrows labeled 'Attack' point to CSR-1, HSR-1, and GM-1. Blue arrows show a path from GM-1 to CSR-1 to O-RU-1, and from GM-2 to CSR-2 to O-RU-2. Green arrows show a path from GM-1 to HSR-1 to CSR-2 to O-RU-2, and from GM-2 to HSR-2 to CSR-1 to O-RU-1. Both O-RU-1 and O-RU-2 are connected to GNSS antennas. + +Figure G-3 + +- The topology shown in Figure G-3, O-RUs do not have secondary network interface connectivity. In this case the network-based sync performance of the O-RU can be monitored using directly connected GNSS recovered phase/time. +- In this model, GNSS port is treated as passive port and compared against the active timeReceiver port (the network interface) as per G.8275.1 Annex G [1] -" Monitoring PTP timeTransmitter port using PTP passive port" +- Other than O-RUs, the transport network elements (HSR and CSR) may exercise redundant network-based passive port monitoring feature for the sync performance monitoring. + +Note: GNSS may have other issues (Jamming, spoofing etc), that can lead to false interpretation of network based recovered time as bad. Therefore, it must be thoroughly analysed whether the issue is from passive port (GNSS) or PTP port (timeReceiver port) + +### G.1.4 Architecture Redundancy for PTP operation for various PTP Security Attacks. + +Various types of attack possible in the PTP enabled network are listed below. + +1. PTP packet content manipulation attack +2. PTP packet removal attack +3. PTP packet Delay Manipulation attack +4. PTP Time Source Degradation attack +5. PTP TimeTransmitter/TimeReceiver Spoofing attack +6. PTP packet Replay attack +7. PTP A-BTCA attack + +#### G.1.4.1 PTP Packet content manipulation attack + +In a packet content manipulation attack, an attacker manipulates suitable fields of PTP packets in transit and affecting the clock synchronization of some or all downstream nodes. The network architectural redundancy ensures that the immediate downstream node(s) to switch to alternate clock path. + +PTP Packet content manipulation attack + +![Diagram illustrating a PTP Packet content manipulation attack. The network topology shows two paths from GNSS sources (GM-1, GM-2) to O-RU nodes (O-RU-1, O-RU-2) via HSR (High Speed Ring) and CSR (Clock Source Redundancy) nodes. A red starburst indicates an attack on the link between HSR-1 and CSR-1. Blue arrows represent the primary path (GM-1 to HSR-1 to CSR-1 to O-RU-1). Green arrows represent the alternate path (GM-2 to HSR-2 to CSR-2 to O-RU-2). A red arrow points to the attack point. Numbers 1 and 2 are placed near the links to indicate the attack target and the alternate path.](865a7cb84ed56f2c1aac75ae04caff27_img.jpg) + +Diagram illustrating a PTP Packet content manipulation attack. The network topology shows two paths from GNSS sources (GM-1, GM-2) to O-RU nodes (O-RU-1, O-RU-2) via HSR (High Speed Ring) and CSR (Clock Source Redundancy) nodes. A red starburst indicates an attack on the link between HSR-1 and CSR-1. Blue arrows represent the primary path (GM-1 to HSR-1 to CSR-1 to O-RU-1). Green arrows represent the alternate path (GM-2 to HSR-2 to CSR-2 to O-RU-2). A red arrow points to the attack point. Numbers 1 and 2 are placed near the links to indicate the attack target and the alternate path. + +Figure G-4: PTP packet content manipulation attack + +##### G.1.4.1.1 Threat scenarios + +An attacker has access to one or more TNEs in the network and intercept and change some or all the parameter's Sync/Follow-Up/Delay-Request/Delay-Response and Announce messages. + +1. Change the *versionPTP* value from (version) 2 to (version) 1 (Note-1). +2. Change the domain-number (Note-1). +3. Change one or more clock parameters such as clockClass, clockAccuracy, offsetScaledLogVariance, priority2, and/or clockIdentity. + +##### G.1.4.1.2 Threat resolution + +In the diagram above, when the versionPTP value or domain number of the PTP attributes change from HSR-1 to CSR-1, the CSR-1 will discard the PTP messages. In such case CSR-1 will select the clock from HSR-2 timeTransmitter port 1. + +When the attacker changes one or more of the clock parameters (clockClass, clockAccuracy, offsetScaledLogVariance, priority2, local priority and clockIdentity), CSR-1 will detect the changes and trigger the A-BTCA to select the clock from HSR-2 timeTransmitter port 1 (Note-2). + +When the attacker changes the *originTimestamp* /*preciseOriginTimestamp* or *correctionField* fields in the PTP messages from HSR-1 and CSR-1, CSR-1 can get the time error based on PTP timestamps on its port 1. If the port 2 of the CSR-1 is a passive monitor port and if the difference of the time error of Passive monitor port 2 and the time error of CSR-1 TimeReceiver port 1 exceeds a threshold, CSR-1 clock may generate an alarm and notify the operator for any corrective action (Note-3). + +#### G.1.4.2 PTP Packet removal attack + +In this attack, an attacker intercepts and remove some or all the PTP packets which can again lead to clock synchronization errors for all downstream nodes. + +![Diagram illustrating a PTP Packet removal attack. The network topology shows two rows of nodes. The top row consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom row consists of O-RU-2, CSR-2, HSR-2, and GM-2. Blue arrows represent the primary clock path: O-RU-1 ← CSR-1 (port 1) ← HSR-1 (port 1) ← GM-1. Green arrows represent the alternate clock path: O-RU-2 ← CSR-2 (port 1) ← HSR-2 (port 1) ← GM-2. Red arrows indicate the attack points where PTP packets are intercepted and removed between CSR-1 and HSR-1, and between HSR-1 and GM-1. Red starburst symbols at these points represent the removal of packets. GNSS symbols are shown pointing to GM-1 and GM-2.](e0883e477b6aeb3815e6ae64aa26db68_img.jpg) + +**PTP Packet removal attack** + +Diagram illustrating a PTP Packet removal attack. The network topology shows two rows of nodes. The top row consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom row consists of O-RU-2, CSR-2, HSR-2, and GM-2. Blue arrows represent the primary clock path: O-RU-1 ← CSR-1 (port 1) ← HSR-1 (port 1) ← GM-1. Green arrows represent the alternate clock path: O-RU-2 ← CSR-2 (port 1) ← HSR-2 (port 1) ← GM-2. Red arrows indicate the attack points where PTP packets are intercepted and removed between CSR-1 and HSR-1, and between HSR-1 and GM-1. Red starburst symbols at these points represent the removal of packets. GNSS symbols are shown pointing to GM-1 and GM-2. + +Figure G-5: PTP packet removal attack + +##### G.1.4.2.1 Threat scenarios + +An attacker selectively intercepts and remove PTP messages causing down-stream node to select an alternate clock path. + +1. An attacker selectively intercepts and removes PTP Announce messages. +2. Attacker selectively intercepts and removes PTP Delay Request messages. +3. Attacker selectively intercepts and removes PTP Sync messages. +4. Attacker intercept and remove all PTP messages. + +##### G.1.4.2.2 Threat resolution + +In the figure G-5 above, the attacker intercepts the network segment between CSR-1 & HSR-1 and HSR-1 & GM-1. Let's say the attacker selectively drops only the Announce messages. Now both CSR-1 TimeReceiver port 1 and HSR-1 TimeReceiver port 1 experiences the Announce-message receipt time-out and CSR-1 & HSR-1 will select the alternate clock HSR-2 and GM-2 respectively based on the A-BTCA (Note-2). + +Consider a case where the attacker selectively drops either sync message or delay-request message or both. In this case CSR-1 TimeReceiver port 1 and HSR-1 TimeReceiver port 1 experiences lack of reception of PTP timing messages from upstream timeTransmitter. Both devices may then report a 'PTSF-lossOfTimingMessages' alarm and generate a state decision event which triggers A-BTCA such that CSR-1 & HSR-1 select the alternate clock HSR-2 and GM-2 respectively (Note-4) + +#### G.1.4.3 PTP Packet Delay Manipulation attack + +PTP requires symmetric path delay between timeTransmitter and timeReceiver to have precise synchronization performance. If propagation delays of a sync message and delay request message are not equal, the timeReceiver clock will experience delay asymmetry or packet delay variation and that leads to synchronization error. + +In this attack, an attacker delays the transmission of PTP packets purposely. As a result, all, or some of the downstream clocks from the attacked node would experience time error. This attack can be mitigated with passive port monitoring feature to detect the possible time error offset change and report it as alarm. + +PTP Packet Delay manipulation attack + +![Diagram illustrating a PTP Packet Delay manipulation attack. The diagram shows a network topology with two rows of nodes. The top row consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom row consists of O-RU-2, CSR-2, HSR-2, and GM-2. Blue arrows represent PTP paths: CSR-1 to O-RU-1, CSR-2 to O-RU-2, GM-1 to HSR-1, GM-2 to HSR-2, and cross-connections between CSR-1/HSR-2 and CSR-2/HSR-1. Green arrows represent data paths: CSR-1 to CSR-2, HSR-1 to HSR-2, GM-1 to GM-2, and cross-connections between CSR-1/HSR-1 and CSR-2/HSR-2. A red starburst with a downward arrow indicates an attack on the link between CSR-1 and HSR-1. Port 1 of CSR-1 is connected to HSR-1, and Port 2 of CSR-1 is connected to HSR-2. GNSS symbols are shown connected to GM-1 and GM-2.](8a9cd7e4f815e65db07dba06541716df_img.jpg) + +Diagram illustrating a PTP Packet Delay manipulation attack. The diagram shows a network topology with two rows of nodes. The top row consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom row consists of O-RU-2, CSR-2, HSR-2, and GM-2. Blue arrows represent PTP paths: CSR-1 to O-RU-1, CSR-2 to O-RU-2, GM-1 to HSR-1, GM-2 to HSR-2, and cross-connections between CSR-1/HSR-2 and CSR-2/HSR-1. Green arrows represent data paths: CSR-1 to CSR-2, HSR-1 to HSR-2, GM-1 to GM-2, and cross-connections between CSR-1/HSR-1 and CSR-2/HSR-2. A red starburst with a downward arrow indicates an attack on the link between CSR-1 and HSR-1. Port 1 of CSR-1 is connected to HSR-1, and Port 2 of CSR-1 is connected to HSR-2. GNSS symbols are shown connected to GM-1 and GM-2. + +Figure G-6 – PTP packet delay manipulation attack + +##### G.1.4.3.1 Threat scenarios + +1. Delay all Sync or Delay Req messages (E.g., between CSR-1 & HSR-1), resulting in an asymmetric path delay between the PTP timeTransmitter on HSR1 and PTP timeReceiver on CSR-1. +2. Delaying all packets from/to the target (i.e., between CSR1 & HSR-1). + +##### G.1.4.3.2 Threat resolution + +Enable Passive Port monitoring feature on CSR-1. Configure Port 2 on CSR-1 as Passive Monitoring Port. When the CSR-1 PTP Passive port receives the Sync and Delay Response messages from the HSR-2 PTP TimeTransmitter port 1, the CSR-1 can compute the time error offset based on PTP timestamps. If difference of the time error offset computed by the Passive port 1 exceeds the threshold, CSR-1 clock may generate an alarm. Note that this alarm is used for PTP monitoring and will not trigger the A-BTCA switchover. An operator can trigger a manual switchover as needed based on the reported alarms. Additionally, the threshold used for this alarm should be properly configured by the operator to avoid false alarms. (Note-3) + +#### G.1.4.4 PTP Time Source Degradation attack + +Time source degradation attacks occur when an attacker compromises the precise time source of the timeTransmitter clock, i.e., T-GM. + +![Diagram of a PTP Time Source Degradation attack. It shows a network topology with two rows of components. The top row consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom row consists of O-RU-2, CSR-2, HSR-2, and GM-2. Blue arrows represent PTP connections: O-RU-1 to CSR-1, CSR-1 to HSR-1, HSR-1 to GM-1, GM-1 to O-RU-2, O-RU-2 to CSR-2, CSR-2 to HSR-2, HSR-2 to GM-2, and GM-2 to O-RU-1. Green arrows represent backup connections: CSR-1 to HSR-2, HSR-1 to CSR-2, GM-1 to HSR-2, and HSR-1 to GM-2. Each connection is labeled with a number (1 or 2). A red arrow labeled 'PTP Time Source Degradation attack' points to a red 'X' over the GNSS symbol next to GM-1, indicating the attack on the grandmaster clock.](c0a01e1839e9441dba35fbb116e3e045_img.jpg) + +PTP Time Source Degradation attack + +Diagram of a PTP Time Source Degradation attack. It shows a network topology with two rows of components. The top row consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom row consists of O-RU-2, CSR-2, HSR-2, and GM-2. Blue arrows represent PTP connections: O-RU-1 to CSR-1, CSR-1 to HSR-1, HSR-1 to GM-1, GM-1 to O-RU-2, O-RU-2 to CSR-2, CSR-2 to HSR-2, HSR-2 to GM-2, and GM-2 to O-RU-1. Green arrows represent backup connections: CSR-1 to HSR-2, HSR-1 to CSR-2, GM-1 to HSR-2, and HSR-1 to GM-2. Each connection is labeled with a number (1 or 2). A red arrow labeled 'PTP Time Source Degradation attack' points to a red 'X' over the GNSS symbol next to GM-1, indicating the attack on the grandmaster clock. + +Figure G-7: Time source degradation attack + +![Diagram of a PTP Time Source Degradation attack with Cs/Rb as backup. The network topology is identical to Figure G-7. However, a black box labeled 'Cs/Rb' is connected to GM-1. A red arrow labeled 'PTP Time Source Degradation attack' points to a red 'X' over the GNSS symbol next to GM-1, indicating the attack on the grandmaster clock.](ecd140ede8c9e57f30bc695e77855af7_img.jpg) + +PTP Time Source Degradation attack + +Diagram of a PTP Time Source Degradation attack with Cs/Rb as backup. The network topology is identical to Figure G-7. However, a black box labeled 'Cs/Rb' is connected to GM-1. A red arrow labeled 'PTP Time Source Degradation attack' points to a red 'X' over the GNSS symbol next to GM-1, indicating the attack on the grandmaster clock. + +Figure G-8: Time source degradation attack with Cs/Rb as backup + +![Diagram of a PTP Time Source Degradation attack at O-RU. The network topology is identical to Figure G-7. A red arrow labeled 'PTP Time Source Degradation attack' points to a red 'X' over the GNSS symbol next to O-RU-1, indicating the attack on the O-RU clock.](4702df3f20e15412a752077078d91f2f_img.jpg) + +PTP Time Source Degradation attack + +Diagram of a PTP Time Source Degradation attack at O-RU. The network topology is identical to Figure G-7. A red arrow labeled 'PTP Time Source Degradation attack' points to a red 'X' over the GNSS symbol next to O-RU-1, indicating the attack on the O-RU clock. + +Figure G-9: Time source degradation attack at O-RU + +##### G.1.4.4.1 Threat scenarios + +1. An attacker can jam or spoof the satellite signals, causing the grandmaster clock to become an incorrect reference time. In this case the jamming signal amplitude value exceeds the configured anti-jamming threshold, the T-GM may raise an alarm and can go into a holdover state. This causes the + +- downstream nodes to receive degraded clock-class value as per ITU-T G.8275.1(11/2022) and triggers the clock selection to select the clock from alternate path. +2. An attacker can jam or spoof the satellite signals at O-RU local GNSS. + +##### G.1.4.4.2 Threat resolution + +In the absence of the GPS jam or spoof signals, say both HSR-1 & HSR-2 select GM-1 as the Time source. When the satellite signal of GM-1 is compromised as shown in Fig G-7, GM-1 may raise an alarm if the jamming signal amplitude exceeds the Anti-jamming threshold configured on GM-1. This can cause GM-1 to go into holdover and advertise Clock Class value of 7 to HSR-1 & HSR-2, which triggers A-BTCA on HSR-1 and HSR-2 to select GM-2 as alternate Time Source (Note-5). + +As shown in Fig G-8, a redundant Rubidium or Caesium clocks is also another option to ensure long term stability in case the GNSS is jammed. When GM-1 satellite signal is jammed, it can use the frequency from the Cs/Rb clock to maintain the phase for several days. This would give the operator enough time to respond to the jamming and neutralize the jamming source. + +In Fig G-9, O-RU uses local GNSS for its synchronization in normal condition. When the satellite signal of local GNSS is compromised, O-RU can switch-over to the backup PTP clock from the network, driven from either GM-1 or GM-2. + +#### G.1.4.5 PTP TimeTransmitter/TimeReceiver Spoofing attack + +In PTP TimeTransmitter Spoofing attack, an attacker impersonates the timeTransmitter clock and distribute false PTP messages causing all clocks downstream to be compromised. In a TimeReceiver spoofing attack, an attacker masquerades as a legitimate intermediate or a timeReceiver clock and transmits compromised delay request messages to the timeTransmitter. + +![Diagram illustrating a PTP Master/Slave Spoofing attack. The network topology shows two rows of nodes. The top row consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom row consists of O-RU-2, CSR-2, HSR-2, and GM-2. Arrows indicate PTP message flows: blue arrows for Sync (1) and Delay Request (2) between adjacent nodes, and green arrows for Sync (1) and Delay Request (2) between GM nodes and HSR nodes. Red starburst symbols with arrows pointing to the links between CSR-1/HSR-1 and HSR-1/GM-1 indicate spoofing attacks. GM-1 and GM-2 are connected to GNSS symbols.](0848623fc215ea184fce1fb78629e333_img.jpg) + +**PTP Master/Slave Spoofing attack** + +Diagram illustrating a PTP Master/Slave Spoofing attack. The network topology shows two rows of nodes. The top row consists of O-RU-1, CSR-1, HSR-1, and GM-1. The bottom row consists of O-RU-2, CSR-2, HSR-2, and GM-2. Arrows indicate PTP message flows: blue arrows for Sync (1) and Delay Request (2) between adjacent nodes, and green arrows for Sync (1) and Delay Request (2) between GM nodes and HSR nodes. Red starburst symbols with arrows pointing to the links between CSR-1/HSR-1 and HSR-1/GM-1 indicate spoofing attacks. GM-1 and GM-2 are connected to GNSS symbols. + +Figure G-9: PTP TimeTransmitter/TimeReceiver Spoofing Attack + +##### G.1.4.5.1 Threat scenarios + +1. An attacker can masquerade as the timeTransmitter by using its MAC/IP address, continuously generate manipulated Sync packets towards the down-stream nodes. +2. An attacker can masquerade as an active GM-1 and send manipulated Sync packets to HSR-1. As a result, HSR-1 & HSR-2 as well as all nodes downstream will be affected. +3. An attacker can continuously create spoofed delay request packets using TimeReceiver MAC/IP address and send them to BC. + +##### G.1.4.5.2 Threat resolution + +When the attacker spoofs the timeTransmitter BC, say HSR-1 port 3 PTP packets, CSR-1 continues to lock to the spoofed clock. However, CSR-1 can get the time error based on PTP timestamps based on the spoofed packets. If the passive port monitoring is enabled on CSR-1 and if the difference of the time error of Passive port and the time error of CSR-1 TimeReceiver port 1 exceeds a threshold, CSR-1 clock may generate an alarm and notify the operator for subsequent action. + +It is also possible that spoofed PTP sync message with a sequence number that does not match its last sync message recorded by the CSR-1. In such case, CSR-1 will discard the sync messages and CSR-1 can report ‘PTSF-lossOfTimingMessages’ alarm and generate a state decision event which triggers A-BTCA so that CSR-1 select the alternate clock from HSR-2. (Note-4) + +Also, if the timeReceiver CSR-1 receives a spoofed delay response message with a sequence number that does not match its last delay request message, the response message will be discarded, and CSR-1 can report ‘PTSF-lossOfTimingMessages’ alarm and generate a state decision event which triggers A-BTCA. + +#### G.1.4.6 PTP Packet Replay attack + +In PTP Packet Replay attack, the attacker continuously records PTP packets and transmits them later without modification. + +![Diagram illustrating a PTP Packet replay attack. The network consists of two rows of nodes. The top row contains O-RU-1, CSR-1, HSR-1, GM-1, and GNSS. The bottom row contains O-RU-2, CSR-2, HSR-2, GM-2, and GNSS. Blue arrows represent normal PTP traffic: GM-1 to HSR-1 (port 1), HSR-1 to CSR-1 (port 1), CSR-1 to O-RU-1; GM-2 to HSR-2 (port 1), HSR-2 to CSR-2 (port 1), CSR-2 to O-RU-2. Green arrows represent reverse traffic: CSR-1 to HSR-1 (port 2), CSR-2 to HSR-2 (port 2), HSR-1 to GM-1 (port 2), HSR-2 to GM-2 (port 2). Red arrows indicate replayed packets from GM-1 and GM-2 to HSR-1 and CSR-1 respectively, marked with red starburst symbols indicating the attack.](45558eaaaa7d40ddcecce0dd3c562fda_img.jpg) + +**PTP Packet replay attack** + +Diagram illustrating a PTP Packet replay attack. The network consists of two rows of nodes. The top row contains O-RU-1, CSR-1, HSR-1, GM-1, and GNSS. The bottom row contains O-RU-2, CSR-2, HSR-2, GM-2, and GNSS. Blue arrows represent normal PTP traffic: GM-1 to HSR-1 (port 1), HSR-1 to CSR-1 (port 1), CSR-1 to O-RU-1; GM-2 to HSR-2 (port 1), HSR-2 to CSR-2 (port 1), CSR-2 to O-RU-2. Green arrows represent reverse traffic: CSR-1 to HSR-1 (port 2), CSR-2 to HSR-2 (port 2), HSR-1 to GM-1 (port 2), HSR-2 to GM-2 (port 2). Red arrows indicate replayed packets from GM-1 and GM-2 to HSR-1 and CSR-1 respectively, marked with red starburst symbols indicating the attack. + +Figure G-10: PTP packet replay attack + +##### G.1.4.6.1 Threat scenarios. + +1. An attacker can record and replay multicast Sync messages from GM as a result, all nodes downstream will be compromised. +2. An attacker can replay multicast Sync messages from BC (HSR-1) and replay them later to a timeReceiver node (CSR-1) as the result, the timeReceiver node will be affected. + +##### G.1.4.6.2 Threat resolution + +When HSR-1 receives the replayed packet from GM-1, since the messages are replayed without modification, the HSR-1 can get the time error based on PTP timestamps from the replayed packets. If the passive port monitoring is enabled on HSR-1 port 2 and if the time error computed at the Passive port of HSR-1 exceeds a threshold, HSR-1 clock may generate an alarm and notify the operator for the follow-up action (Note-3). + +Also, if the timeReceiver of CSR-1 receives a replayed PTP event message with a sequence number that does not match its last message, the replayed message will be discarded, and CSR-1 can report ‘PTSF- + +lossOfTimingMessages' alarm and generate a state decision event which triggers A-BTCA so that HSR-1 can lock to GM-2. + +The above PTP switchover applies to the CSR-1 as BC receiving replayed PTP packet from HSR-1. + +#### G.1.4.7 PTP A-BTCA attack + +In a PTP A-BTCA attack, an attacker guides other network clocks to elect it as the best timeTransmitter by tampering with the A-BTCA algorithm. Here the A-BTCA attacker does not fake its identity but tampers with the timeTransmitter election process by advertising superior clock attributes, and once get elected – manipulates the synchronization of the timeReceiver clocks. + +![Diagram illustrating a PTP A-BTCA attack. The network topology shows O-RU-1 connected to CSR-1, which is connected to HSR-1. O-RU-2 is connected to CSR-2, which is connected to HSR-2. GM-1 is connected to HSR-1 and HSR-2. GM-2 is connected to HSR-2 and is also connected to GNSS. GM-1 is labeled as a 'Rogue master' and is circled in red. Arrows indicate the flow of PTP messages: blue arrows for normal operation and green arrows for the attack. Blue arrows show GM-1 sending message 1 to HSR-1, which then sends message 2 to CSR-1. Green arrows show GM-1 sending message 1 to HSR-2, which then sends message 2 to CSR-2. GM-2 sends message 1 to HSR-2, which then sends message 2 to CSR-2. The GNSS is also connected to GM-2.](b7b98c779dadac100ce83854aaca4bf2_img.jpg) + +**PTP A-BTCA attack** + +Diagram illustrating a PTP A-BTCA attack. The network topology shows O-RU-1 connected to CSR-1, which is connected to HSR-1. O-RU-2 is connected to CSR-2, which is connected to HSR-2. GM-1 is connected to HSR-1 and HSR-2. GM-2 is connected to HSR-2 and is also connected to GNSS. GM-1 is labeled as a 'Rogue master' and is circled in red. Arrows indicate the flow of PTP messages: blue arrows for normal operation and green arrows for the attack. Blue arrows show GM-1 sending message 1 to HSR-1, which then sends message 2 to CSR-1. Green arrows show GM-1 sending message 1 to HSR-2, which then sends message 2 to CSR-2. GM-2 sends message 1 to HSR-2, which then sends message 2 to CSR-2. The GNSS is also connected to GM-2. + +Figure G-11: PTP A-BTCA attack + +##### G.1.4.7.1 Threat scenarios + +1. A rogue timeTransmitter sends continuously crafted announce messages that carry the best clock attributes (i.e., clockClass, clockAccuracy, offsetScaledLogVariance, priority2, local priority and clockIdentity) of the network to tamper with the ABTC algorithm. As a result, all nodes downstream will rely on this compromised time reference. + +##### G.1.4.7.2 Threat resolution + +Before the attack let's assume that there is only one GM (GM-2) in the network and both HSR1 & HSR2 are locked to GM-2. Assume the clock attributes advertised by GM-2 is given below. + +Dataset : (clockClass, clockAccuracy, offsetScaledLog-Variance, priority2, local priority and clockIdentity) of GM-2 = (6, 33, 20061, 2, ID2) + +Now let's assume a rogue timeTransmitter GM-1 got added to the network which sends crafted announce message with clock attributes better than that of GM-2 as below. + +Dataset: (clockClass, clockAccuracy, offsetScaledLog-Variance, priority2, local priority and clockIdentity) of GM-1 = (6, 33, 20061, 1, ID1) + +HSR-1 and HSR-2 now run A-BTCA and select GM-1 as the best timeTransmitter. However, the GM-1 is a rogue timeTransmitter it can generate incorrect timestamps in its generated event packets. If both HSR1 and HSR2 have the passive port monitoring enabled, then both HSR1 and HSR2 can generate an alarm. Operator can then initiate a manual switch to GM-2 by determining which source is a better source (Note-2). + +1 +2 +3 +4 +5 +6 +7 +8 +9 +10 + +- Note-1: Refer section 6.3.8 of ITU-T G.8275.1[1]. It says a compliant clock must discard on reception of ingress packets when these fields are outside of the allowed range for the profile. +- Note-2: Refer section 6.3.1 & 6.3.7 of ITU-T G.8275.1[1] for A-BTCA and Dataset comparison algorithm. +- Note-3: Annex G in ITU-T G.8275.1 [1] describes the optional Passive Port Monitoring support. +- Note-4: Section 6.3.9 in ITU-T G.8275.1 [1] describes the optional support for Packet Timing Signal Fail (PTSF) support. If this is implemented, and when a PTSF occurs, the clock may set the PTP portDS.SF to TRUE and generate a state decision event, which would trigger the alternate BTCA. +- Note-5: Refer Table 3 of ITU-T G.8275.1 [1] for applicable clockClass values. + +# Annex H: End-to-end (e2e) Sync Monitoring using the Centralized Monitoring System + +## H.1 Introduction + +The precision of a frequency/phase and time recovered at the end of the synchronization chain depends on any single node or combination of multiple nodes in the sync network. The sum of the timing errors introduced at all nodes along the synchronization path needs to be within the required timing budget for a given application. If there is an issue with nodes synchronization in a sync network chain, it is very complex to identify which node had introduced the issue. + +End-to-end Sync monitoring feature can be used to identify synchronization issues in the network, correlation of timing events and much more. It can be used to monitor the health of the nodes in synchronization network and assess the timing performance of the node as well as complete synchronization network chain. + +End-to-end Sync monitoring feature is exercised in the Centralized Monitoring System (CMS). Every node in the network chain will be monitored for the synchronization events and their impact on the node as well as on the network. + +![Figure H-1: End-to-end Sync Monitoring Topology. The diagram illustrates a synchronization chain and its connection to a Centralized Monitoring System (CMS). The chain consists of nodes: T-GM, T-BC-1, T-BC-2, T-BC-N, and O-RU. T-GM is connected to T-BC-1, which is connected to T-BC-2, which is connected to T-BC-N, which is connected to O-RU. A dashed red line connects T-BC-2 to T-BC-N. An O-DU node is connected to T-BC-N. A green oval labeled 'Sync Data Export' points to the CMS. A red oval labeled 'Radio/App Error Detected' points to the O-RU. Yellow callouts above the nodes indicate monitoring points: 'Clock Drift, GNSS?' for T-GM, 'PTP Unlocked?' for T-BC-1, 'Sync-E Unlocked?' for T-BC-2, and 'Transient Error?' for T-BC-N.](c600fadfeb1d94dc7da96882441035cc_img.jpg) + +``` + +graph LR + TGM[T-GM] --> TBC1[T-BC-1] + TBC1 --> TBC2[T-BC-2] + TBC2 -.-> TBCN[T-BC-N] + TBCN --> ORU[O-RU] + ODU[O-DU] --> TBCN + CMS[Centralized Monitoring system] + TGM -.-> CMS + TBC1 -.-> CMS + TBC2 -.-> CMS + TBCN -.-> CMS + ORU -.-> CMS + +``` + +Figure H-1: End-to-end Sync Monitoring Topology. The diagram illustrates a synchronization chain and its connection to a Centralized Monitoring System (CMS). The chain consists of nodes: T-GM, T-BC-1, T-BC-2, T-BC-N, and O-RU. T-GM is connected to T-BC-1, which is connected to T-BC-2, which is connected to T-BC-N, which is connected to O-RU. A dashed red line connects T-BC-2 to T-BC-N. An O-DU node is connected to T-BC-N. A green oval labeled 'Sync Data Export' points to the CMS. A red oval labeled 'Radio/App Error Detected' points to the O-RU. Yellow callouts above the nodes indicate monitoring points: 'Clock Drift, GNSS?' for T-GM, 'PTP Unlocked?' for T-BC-1, 'Sync-E Unlocked?' for T-BC-2, and 'Transient Error?' for T-BC-N. + +Figure H-1: End-to-end Sync Monitoring Topology + +## H.2 Various elements of e2e sync monitoring + +### H.2.1 Nodes + +An element in the network chain referred as a Node. Node can act as a PTP boundary clock, grandmaster clock and/or end-time-receiver clock (shortly called as sync-nodes) in the synchronization chain. A Node can also extract clock information (Physical Layer Frequency) from physical interface. + +Nodes are responsible for either generating, consuming or propagating frequency and time information over the synchronization network. + +### H.2.2 The Centralized Monitoring System (CMS) + +This is a monitoring service running on a server or similar platform in a cloud or on-premise, to receive timing telemetry data from the nodes in the synchronization network chain. It is critical for the CMS to get timing telemetry data from all nodes in the synchronization Network. + +The CMS shall analyse the telemetry data, do monitoring and reporting the health of the synchronization network. + +## H.3 CMS Implementation + +Each Node in synchronization chain exports synchronization protocol (PTP) and state machine attributes. Most of these attributes are referenced from IEEE1588 2019 [42] and ITU-T G.781 [19], G.7721.1 [43] standards. Some of the attributes are newly defined for End-to-end Sync Monitoring feature to support monitoring and reporting requirements. The ITU-T PTP profiles (G.8275.1 [1] and G.8275.2 [3]) include the Performance Monitoring option defined in G.8275 [41] Annex F that is based on IEEE1588-2019 Annex J [42]. + +Yang data model-based telemetry mechanism shall be used to receive synchronization attributes from the nodes. + +The CMS and nodes can use gNMI or NETCONF for streaming the data. + +Each node in the synchronization chain has a secure telemetry session with the CMS. This session can be initiated either by a node or the CMS based on the management model. If a session is terminated, the CMS shall report and log accordingly. Session can be re-established as per node accessibility for secure session as per the transport protocol used. + +The telemetry interface shall use push subscription model to deliver data asynchronously. A request to “send data” only once by the CMS to stream periodic updates by the nodes (Periodic subscriptions). + +Periodic streaming is less useful for time-critical events, in such instances, the CMS shall be configured for “On Change/Notification” to receive streaming information whenever operational state changes (On-Change Subscriptions). + +The CMS shall process these synchronization attributes and state change notifications from all the nodes in the synchronization network chain and perform the static analysis as specified in section H.3.2. The protocol and state attributes/data sets are shown in Table H.4-1, Table H.4-2 and Table H.4-3. + +The computation logic shall report various events as described in section H.3.2. Event reporting can be visualized on UI interface and it is out of scope of this ORAN specification. The CMS may also keep history of attributes and various events reported by the nodes. + +The Computation Logics at the CMS can be categorized as: + +### Static Analysis: + +Static analysis is a computational model exercised by the CMS to gather, analyze, and report per node basis. In this model the entire topology is not considered for detection, correlation and reporting. + +This static analysis model would focus on reporting of synchronization operational, functional and protocol states per node basis information/failures/issues using each node reported telemetry attributes and does not address dynamic changes of the synchronization network (e.g, reconfigurations). + +### Dynamic Analysis: + +Dynamic analysis is a computational model in which the entire synchronization network topology considered for detection, correlation and reporting. + +As part of Dynamic analysis, the correlation and analysis of attributes from various nodes in the synchronization chain used to determine the overall synchronization network behavior. + +Note-1: The End-to-end sync monitoring framework and datasets described in this specification focuses only G.8275.1 profile. Other ITU-T profiles are for future study. + +### H.3.1 Datasets reference + +- This ORAN specification focuses on the static analysis model for this release. +- The datasets required for the static analysis model are documented in Table Table H.4-2 & Table H.4-3. +- For a node to participate in End-to-end sync Monitoring feature, it must support telemetry attributes listed in Table Table H.4-2 & Table H.4-3. +- The YANG data model for the various datasets will be defined in the future release of this ORAN specification. + +### H.3.2 Static Analysis + +#### Req-1: Node Role reporting + +- Node Role specifies about the node type. A node can be a T-BC, T-TC, T-GM, T-TSC, O-DU TimeTransmitter/BC/TSC & O-RU TSC. +- This reporting gives an insight to the operator about where the sync chain is starting (if the node is T-GM), where it ends (if the node is T-TSC or O-RU) or a transit node in the chain (T-BC). +- defaultDS.ptpTelecomProfile.deviceType and defaultDS.oranE2eSyncMonitoring.extendedDeviceType datasets shall be used to identify the node role. + +#### Req-2: Node Class reporting + +- This provides Node's PTP Class of compliance information as per ITU-T and O-RAN standard clock specification (G.8273.2 [2], G.8273.3 [4], G.8273.4 [39], G.8273.1, O-RAN.WG4.CUS [33], etc), and + +with this attribute the CMS figure out sync node's expected timing performance capability as per maxTE, dTE and cTE metrics. + +- defaultDS.ptpTelecomProfile.nodeClass attribute shall be used for this reporting. + +#### Req-3: Node Clock mode (synchronization state of the node) reporting + +- The node synchronization state should be monitored (Freerun, Locked, Acquiring, Holdover-within-specification and Holdover-out-of-specification). This would indicate whether a node is recovering the clock/time information from the upstream timeTransmitter node or not. +- The clockMode dataset defined in ITU-T G.8275 [41] appendix VIII provides information of node synchronization state. +- Monitoring logic in CMS shall report any change in Node's synchronization state. +- Below attributes will be monitored to fulfil requirement under this section: + - currentDS.ptpTelecomProfile.clockMode + +#### Req-4: Upstream TimeTransmitter or GM change reporting + +- Monitoring system shall report if there is a change in the upstream TimeTransmitter or Grandmaster detected. +- Report any parent attributes that is changed in parent-ds data set attributes. +- Any change in upstream TimeTransmitter's attributes may impact downstream node's synchronization state. +- Below attributes will be monitored for any change by CMS to report this: + - parentDS.parentPortIdentity.clockIdentity + - parentDS.grandmasterIdentity + - parentDS.grandmasterClockQuality + - parentDS.grandmasterPriority2 + +#### Req-5: Time offset and delay reporting + +- The CMS shall compute time offset and path delays (using T1, T2, T3 & T4 time-stamps) based on the received ptpTimestampRecordDS per node basis. +- The CMS shall report path delay variation of the PTP packets. +- The CMS shall identify and report the nodes/links contributing the change in path delays, clock drift in relation to upstream nodes. + +Note-2: The node shall either send all ptp timestamp data or no timestamp data (refer ptpTimestampRecordDS in H.4.3.1 section) + +#### Req-6: All available timeTransmitters reporting + +- Report all available upstream/foreign timeTransmitters seen by a node using allTimeTransmitterDS defined as part of this specification in section H.4.3.2. +- Order them from "the selected timeTransmitter" to the "least preferable timeTransmitter" by executing the A-BTCA algorithm iteratively with allTimeTransmitterDS. +- Detect and report if same timeTransmitter seen in more than one interface. + +#### Req-7: Clock traceability information change detection and reporting + +- Detect and report all clock traceability information changes. This includes time-traceability, frequency traceability attributes. + +- Below attributes will be monitored to fulfil requirement under this section: + - timePropertiesDS.timeTraceable + - timePropertiesDS.frequencyTraceable + - timePropertiesDS.timeSource + +#### Req-8: Clock quality reporting + +- Detect and report the clock-class change irrespective of A-BTCA switchover triggered or not. +- Report any difference in Tx and Rx clock-class value. +- Report any change in Clock Accuracy information. +- Below attributes will be monitored to fulfil this requirement: + - defaultDS.clockQuality + +#### Req-9: Report A-BTCA switchover flapping + +- Detect and report if a node is keep flip-flapping between two upstream (timeTransmitter) nodes and any associated reason for the flip-flap. +- Report how often the node is going back and forth with the same set of upstream timeTransmitters. +- One model to detect the flapping is to identify, if any given node switches back and forth more than twice between the same two upstream timeTransmitters or GMs within 30 minutes window. +- Below attributes will be monitored to implement this requirement: + - parentDS.grandmasterIdentity + - parentDS.parentPortIdentity.clockIdentity + +#### Req-10: Report the selected TimeTransmitter attributes + +- Report both parent and GM attributes of the selected timeTransmitter. +- Below attributes will be monitored in this requirement: + - parentDS.parentPortIdentity + - parentDS.grandmasterIdentity + - parentDS.grandmasterClockQuality + - parentDS.grandmasterPriority1 + - parentDS.grandmasterPriority2 + - timePropertiesDS + +### H.3.3 Dynamic Analysis + +The dynamic analysis model is not covered in this specification. It is for further study. + +## H.4 Telemetry Datasets + +### H.4.1 High Level Datasets + +The Table H.4-1 in this section describes list of high level data sets needed to implement the requirements listed in the section H.3.2. + +| Data set | Description | +|--------------------------------------------|--------------------------------------------------------------------------------------------------------------------| +| <b>clockIdentity</b> | 8-byte PTP clock identity that uniquely identifies a particular node. | +| <b>clockMode</b> | State describing as Holdover-within-specification, Holdover-out-of-specification, Acquiring, Free run and locked. | +| <b>Tx clockClass</b> | PTP clock class transmitted to downstream timeReceivers. | +| <b>Rx clockClass</b> | PTP clock class received from upstream timeTransmitter. | +| <b>grandmasterIdentity & data set</b> | Clock identity of the Grandmaster clock and its data set. | +| <b>Parent clockIdentity & Data set</b> | Clock identity of upstream timeTransmitter and its data set. | +| <b>frequencyTraceable</b> | True or False based Sync-E present or not. | +| <b>timeTraceable</b> | True or False based on PTP time source traceable or not. | +| <b>nodeClass</b> | CLASS-A, B, C, D, PRTC-A, PRTC-B, ePRTC-A, ePRTC-B, O-RU- REGULAR, O-RU-ENHANCED, O-DU-CLASS-A, O-DU-CLASS-B, etc. | +| <b>Source portIdentity and portState</b> | For all configured ports/interfaces. | +| <b>All TimeTransmitter info</b> | All PTP timeTransmitters info including interface on which it is reachable | +| <b>deviceType</b> | T-GM, T-BC, T-TC, T-TSC, T-BC-A, T-BC-P, T-TSC-A. | +| <b>extendedDeviceType</b> | O-DU-TimeTransmitter, O-DU-BC, O-DU-TSC, O-RU-TSC | + +**Table H.4-1: High Level Telemetry Datasets** + +The data set described in Table H.4-1 is the critical but not limited to protocol and state information which will be shared by a PTP node to the CMS. + +Note-3: O-DU and O-RU DeviceTypes are not defined in ITU-T specification, therefore an extended device type is defined to identify the ORAN devices/clocks. The O-DU-BC type shall be used for an O-DU supporting LLS-C1/C2 configuration models, while O-DU-TSC type shall be used for LLS-C3 configuration model. + +### H.4.2 Detailed attributes/datasets + +The Table H.4-2 defines the telemetry attributes which are required by the telemetry client (CMS) to fetch the PTP monitoring information from a node. The End-to-end Sync Monitoring described in this specification refers to a subset of attributes from IEEE1588 2019 [42] and ITU\_T [43], [41] standards. The “Comments” column of Table specifies the attributes associated with the corresponding standard’s reference. + +There are some additional dataset attributes listed in Table H.4-3 that are defined as part of this specification and needed to implement End-to-end sync monitoring features defined in section H.3. The “Comments” column of the table specifies reference of the dataset member if referred from an external standard, or it is newly defined under this ORAN specification. + +1 +2 +3 + +| Attributes | Definition | Data type | Comments | +|--------------------------------------|---------------------------------------------------------------------------------------------------------------------------|------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| defaultDS data set members | | | Defined in IEEE1588 2019 spec: 8.2.1 defaultDS data set member specifications [42] | +| instanceType | Specifies the type of PTP Instance. This instanceType is similar in purpose to the clockType of PTP management messages. | ENUM [ OC, BC p2pTC e2eTC, ] | Defined in 1588 2019 spec: Section 8.2.1.5.5 & Table 8 instanceType enumeration[42] | +| currentTime | This member shall return the current value of the PTP Instance Time. | Timestamp | Defined in IEEE1588-2019 spec: Section 8.2.1.5.1 & Section 3.1.54 [42]<br>In most cases, the actual precision is on the order of milliseconds or worse depending on the source of the information used in populating the data field and on the characteristics of the network. | +| domainNumber | PTP Domain. | UInteger8 (0-255) | Defined in IEEE1588-2019 spec: Section 8.2.1.4.3 & Section 7.1 [42] | +| clockIdentity | Each PTP Instance shall be associated with a single clockIdentity value. This value shall be unique within a PTP Network. | ClockIdentity (OCTET [8]) | Defined in IEEE1588-2019 spec: Section 7.6.2.2 & Section 8.2.1.2.2 [42] | +| clockQuality.clockClass | The ClockQuality represents the quality of a clock. | UInteger8 | Defined in IEEE1588-2019 spec: Section 8.2.1.3.1.2, Section 7.6.2.5 & Table 4 – clockClass specifications [42] | +| clockQuality.clockAccuracy | | Enumeration8 | Defined in IEEE1588-2019 spec: Section 8.2.1.3.1.3, Section 7.6.2.6 & Table 5 – clockAccuracy enumeration [42] | +| clockQuality.offsetScaledLogVariance | | uint16 | Defined in IEEE1588-2019 spec: Section 8.2.1.3.1.4, Section 7.6.2.7 & Section 7.6.3.5. [42] | +| priority1 | The attribute priority1 is used in the execution of the best timeTransmitter clock algorithm. | UInteger8 0 to 255 | Defined in IEEE1588-2019 spec: Section 8.2.1.4.1 & Section 7.6.2.3 [42] | + +| | | | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| priority2 | The attribute priority2 is used in the execution of the best timeTransmitter clock algorithm. | UInteger8<br>0 to 255 | Defined in IEEE1588-2019 spec: Section 8.2.1.4.2 & Section 7.6.2.4 [42] | +| maxStepsRemoved | If the value of stepsRemoved of an Announce message is greater than or equal to the value of defaultDS.maxSteps Removed, the Announce message is not considered in the operation of the A-BTCA. | UInteger8 | Defined in IEEE1588-2019 spec: Section 8.2.1.5.4 [42] | +| ptpTelecomProfile | | | PTP attributes for the PTP instance defined in ITU-T G.7721.1 [43], ITU-T G.8275.1 [1] & ITU-T G.8275.2 [3]. | +| localPriority | | uint8 | Defined in ITU-T 7721.1 spec [43] | +| deviceType | The clock type of a PTP Telecom Profile instance. | ENUM {<br>t-gm,<br>t-tsc,<br>t-bc,<br>t-tsc-a,<br>t-tsc-p,<br>t-bc-a,<br>t-bc-p,<br>} | Refer Table-1 in ITU-T G.8275.1 [1]& G.8275.2 [3]<br>O-DU & O-RU types shall be added as part of oran e2e sync monitoring Yang data model. | +| nodeClass | The nodeClass dataset represents the clock node's time error performance compliance | ENUM{<br>PRTC-A,<br>PRTC-B,<br>ePRTC-A,<br>cnPRTC,<br>Class-A,<br>Class-B,<br>Class-C,<br>Class-D,<br>O-RU- Regular,<br>O-RU- Enhanced,<br>O-DU-Class-A,<br>O-DU-Class-B<br>} | Refer Table-4 in ITU-T G.8275.1 [1]& Table-6 in ITU-T G.8275.2 [3]<br>ITU-T Recommendation G.8273.2/Y.1368.2 [2]<br><br>ITU-T Recommendation G.8272.1/Y.1367.1 [6]<br><br>O-RAN Control, User and Synchronization Plane Specification [33]<br><br>O-RU- Regular (0x61), O-RU- Enhanced(0x62), O-DU-Class-A(0x63), O-DU-Class-B(0x64), are using reserved range 0x61 to 0xFF for SDOs. | +| clockMode | clockMode provides synchronization state of the PTP clock. | ENUM{<br>Free-Run,<br>Acquiring,<br>Locked,<br>Holdover-within-specification, | Refer Table-3 in ITU-T G.8275.1 [1]& Table-5 in ITU-T G.8275.2 [3]<br><br>Refer G.8275 Appendix VIII. [41] | + +| | | | | +|--------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------| +| | | Holdover-out-of-specification, } | | +| currentDS data set members | | | Defined in IEEE1588 2019 spec: 8.2.2 currentDS data set member specifications [42] | +| offsetFromTimeTransmitter | The current value of the time difference between a TimeTransmitter PTP Instance and a TimeReceiver PTP Instance as computed by the TimeReceiver PTP Instance. | TimeInterval | Defined in IEEE1588-2019 spec: currentDS.offsetFromMaster, Section 8.2.2.3 [42] | +| meanDelay | mean propagation time. | TimeInterval | Defined in IEEE1588-2019 spec: Section 8.2.2.4. [42]<br>Applicable when portDS.delayMechanism (table 21 of Section 8.2.15.4.4) is implemented. | +| parentDS data set members | | | Defined in IEEE1588 2019 spec: 8.2.3 parentDS data set member specifications [42] | +| parentPortIdentity.clockIdentity | clockIdentity of the PTP Port on the TimeTransmitter PTP Instance. | ClockIdentity | Defined in IEEE1588-2019 spec: Section 8.2.3.2 & Section 5.3.5 [42] | +| grandmasterIdentity | clockIdentity of the PTP Port on the GM PTP Instance. | ClockIdentity | Defined in IEEE1588-2019 spec as Section 8.2.3.6 & 7.6.2.2 [42] | +| grandmasterClockQuality.clockClass<br>clockAccuracy<br>offsetScaledLogVariance | clockQuality attribute of the Grandmaster PTP Instance. | ClockQuality | Defined in IEEE1588-2019 spec: Section 8.2.3.7<br>Table 4 – clockClass specifications [42] | +| grandmasterPriority1 | priority1 attribute of the GM PTP Instance. | UInteger8 | Defined in IEEE1588-2019 spec: Section 8.2.3.8 [42] | +| grandmasterPriority2 | priority2 attribute of the GM PTP Instance. | UInteger8 | Defined in IEEE1588-2019 spec: Section 8.2.3.9 [42] | +| parentStats | If True, The PTP Instance has computed statistically valid estimates of the parentDS.observedParentOffsetScaledLogVariance and the parentDS.observedParentClockPhaseChangeRate members. | Boolean | Defined in IEEE1588-2019 spec: Section 8.2.3.3 [42] | +| observedParentOffsetScaledLogVariance | Estimate of the variance of the phase | UInteger16 | Defined in IEEE1588-2019 spec: Section 8.2.3.4 [42] | + +| | | | | +|-------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------|---------------------------------------------------------------------------------------------------------------| +| | offset of the Local PTP Clock of the Parent PTP Instance as measured with respect to the Local PTP Clock in the TimeReceiver PTP Instance. | | | +| observedParentClockPhase-ChangeRate | Estimate of the phase change rate of the Local PTP Clock of the Parent PTP Instance as measured by the TimeReceiver PTP Instance using its Local PTP Clock. | Integer32 | Defined in IEEE1588-2019 spec: Section 8.2.3.5 [42] | +| timePropertiesDS data set members | | | Defined in IEEE1588 2019 spec: 8.2.4 timePropertiesDS data set member specifications [42] | +| timeTraceable | To indicate that timescale is traceable to a primary reference. Also indicates the node is in Phased locked state. | Boolean | Defined in IEEE1588-2019 spec: Section 8.2.4.6 [42] | +| frequencyTraceable | To indicate that frequency determining the timescale is traceable to a primary reference; Also indicates the node is frequency locked state. | Boolean | Defined in IEEE1588-2019 spec: Section 8.2.4.7 [42] | +| timeSource | This attribute indicates the immediate source of time used by the Grandmaster PTP Instance. | ENUM<br>IEEE1588-2019<br>Table 6 –<br>timeSource | Defined in IEEE1588-2019 spec: Section 8.2.4.9 & Table 6 – timeSource [42] | +| portDS data set members | | | Defined in IEEE1588 2019 spec: 8.2.15 portDS data set member specifications [42] | +| +-- ports<br>+-- port [] | List of portDS. | | Records of portDS datasets defined in IEEE1588-2019 spec. [42]<br>Contains all PTP Ports in the PTP instance. | +| portIdentity.clockIdentity<br>portIdentity.portNumber | portIdentity attribute of the local PTP Port | PortIdentity<br>(ClockIdentity,<br>portNumber) | Defined in IEEE1588-2019 spec: Section 8.2.15.2.1 [42] | + +| | | | | +|-------------------------|--------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| delayMechanism | The path delay measuring mechanism used by the PTP Port. | ENUM (e2e, p2p, NO_MECHANISM, COMMON_P2P, SPECIAL) | Defined in IEEE1588-2019 spec: Section 8.2.15.4.4 & Table 21 – Delay mechanism enumeration [42] | +| portState | current state of the protocol engine associated with the PTP port. | ENUM (INITIALIZING, FAULTY, DISABLED, LISTENING, PRE_TIME_TRANSMITTER, TIME_TRANSMITTER, PASSIVE, UNCALIBRATED, TIME_RECEIVER) | Defined in IEEE1588-2019 spec: Section 8.2.15.3.1 & Table 20 – PTP state enumeration [42] | +| delayAsymmetry | Delay asymmetry applicable to the PTP Port. | TimeInterval | Defined in IEEE1588-2019 spec: Section 8.3.15.4.8 [42] | +| ptpTelecomProfile | | | ITU-T G.7721.1 [43], ITU-T G.8275.1 [1] & ITU-T G.8275.2 [3]. | +| localPriority | | uint8 | Defined in ITU-T 7721.1 spec [43] | +| performanceMonitoringDS | | | PTP Telecom profiles enhanced the IEEE1588 Annex J Performance [42] Monitoring option as per ITU-T G.8275 Annex F [41] | +| performanceMonitoringDS | Performance monitoring. | | The data provided by a node compliant with G.8275.1 [1] or G.8275.2 [3] is expected to be compliant with G.8275 [41] Annex F rather than IEEE1588-2019 Annex J [42]. | + +**Table H.4-2: Detailed attributes/datasets** + +Note-4: For the newly defined dataset attributes (Table H.4-3), a separate End-to-end sync monitoring attributes hierarchy is created. + +This is done considering following points: + +- It provides a cleaner approach to implement End-to-end Sync Monitoring requirements. +- Member under End-to-end sync monitoring dataset hierarchy would not collide with newly defined attributes in other standard organization. +- In future, if standard defined dataset member overlap with End-to-end sync monitoring dataset member, attribute under End-to-end sync monitoring dataset hierarchy can be deprecated and monitoring logic can use standard defined dataset member. This can be done without any complexity involved. + +| Attributes | Definition | Data type | Comments | +|------------|------------|-----------|----------| +|------------|------------|-----------|----------| + +| | | | | +|-----------------------------------------|-----------------------------------------------------------------------|------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| defaultDS.oranE2eSyncMonitoringDS | | | Added attributes for default data set under oranE2eSyncMonitoringDS node. | +| isSupported<br>(static) | If True, End to End monitoring feature is supported on the Sync Node. | Boolean | | +| supportedVersion<br>(static) | Version of End-to-end sync monitoring feature. | UInteger8 | This release of specification supported version is 1. The node must explicitly set this value when exporting the e2e-sync monitoring attributes to the CMS | +| extendedDeviceType<br>(configurable) | Extended device type to cover ORAN specific clocks/devices | ENUM {<br>Not-Applicable,<br>O-DU-TimeTransmitter,<br>O-DU-BC,<br>O-DU-TSC,<br>O-RU<br>} | ITU-T device types do not cover ORAN clock types. These extended device types shall be used to identify ORAN devices/clocks.<br><br>Non ORAN devices shall set this attribute as NOT-APPLICABLE.<br><br>CMS shall use this extendedDeviceType if it is set to other than NOT-APPLICABLE and ignore the ITU-T defined DeviceType. | +| currentDS.oranE2eSyncMonitoringDS | | | Added attributes for current data set under oranE2eSyncMonitoringDS node. | +| timeSinceCurrentClockState<br>(dynamic) | Time elapsed in current clock-state | UInteger32. | Time elapsed in current clock-state. Identify clock stability (In seconds). | +| oranE2eSyncMonitoringDS | Below nodes are under oranE2eSyncMonitoringDS hierarchy. | | | +| ptpTimestampRecordsDS | List of PTP timestamp data set. (T1, T2, T3, T4 time matrix.) | | Record for PTP packets matrix. | +| updateFrequency<br>(configurable) | “PTP timestamp record” collection frequency in secs. | UInteger8 | In Secs. Recommended frequency to update is 10 seconds. | +| numberOfRecords<br>(configurable) | If non-zero, PTP timestamp valid records are available. | UInteger16 | Node shall set this field as zero if it does not support streaming of the timestamps (T1, T2, T3 & T4). | +| timestampInfo | PTP timestamp data set (T1, T2, T3, T4 time matrix) | list | Monitoring rate:<br>One sample/sec | +| timestampInfo.index<br>(dynamic) | Index/key for the timestamp-info list. | UInteger16 | Newly defined attribute for list indexing. | + +| | | | | +|-------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| timestampInfo.timestampRecord | PTP Timestamp data record.<br>Sync/delay-request message information. | Container | | +| timestampRecord | | | Attributes in “ptpTimestampRecordsDS.timestampInfo.timestampRecord” hierarchy | +| recordTime (dynamic) | Record time - System time at which msg was recorded | UInteger64 | | +| t1sec (dynamic) | t1 and t2 represent the Tx/Origin timestamp and Receiver Timestamp respectively for a given message type in a particular direction (sync or delay request message).<br><br>For sync message: timestamp-record t1 & timestamp-record t2 denote t1 and t2 timestamps as defined in PTP 1588v2.<br><br>For delay request message: timestamp-record t1 & timestamp-record t2 denote t3 and t4 timestamps as defined in PTP 1588v2. | UInteger64 | The seconds-field member is the integer portion of the timestamp in units of seconds. Since the IEEE 1588 type is Uinteger48, only 48 bits are represented in YANG. | +| t1nsec (dynamic) | | UInteger32 | The nanoseconds-field member is the fractional portion of the timestamp in units of nanoseconds. | +| t2sec (dynamic) | | UInteger64 | The seconds-field member is the integer portion of the timestamp in units of seconds. Since the IEEE 1588 type is Uinteger48, only 48 bits are represented in YANG | +| t2nsec (dynamic) | | UInteger32 | The nanoseconds-field member is the fractional portion of the timestamp in units of nanoseconds. | +| sequenceId (dynamic) | Sequence-id: Sequence number used in the packet (Sync/Delay-req). | UInteger16 | Refer IEEE1588-2019: Section: 7.3.7 PTP message sequenceId [42]. | +| cf (dynamic) | Cf: Correction field value of the Message. | Integer64 | | +| pathDelay (dynamic) | Path-delay: Computed PTP Packet Path delay (TimeTransmitter-to-TimeReceiver and TimeReceiver-to- | Integer64 | | + +| | | | | +|---------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------| +| | TimeTransmitter based on the message type) | | | +| messageType (dynamic) | Message-type: Sync or delay-request/response. | UInteger8<br>ENUM<br>{<br>SYNC,<br>DELAY-REQ<br>} | Refer IEEE1588-2019 spec. Table-36 – Values of message Type field [42]. Only Sync and DelayReq messageType are applicable here. | +| allDS | | | allTimeTransmitterDS data set members for End-to-end sync monitoring. | +| allTimeTransmitterDS.timeTransmitter | Container for all remote timeTransmitters' records collected from different timeTransmitter via announce message for A-BTCA selection. | list | Foreign master as defined in IEEE1588-2019 spec. [42] | +| timeTransmitter | | | Attributes in “allTimeTransmitterDS.timeTransmitter” hierarchy | +| parentDS.parentPortIdentity.clockIdentity.portNumber (dynamic) | timeTransmitter Port Identity. | portIdentity | parentDS is defined in IEEE1588-2019 spec. [42] | +| parentDS.grandmasterIdentity (dynamic) | Clock Identity of the GM. | clockIdentity | parentDS is defined in IEEE1588-2019 spec. [42] | +| parentDS.grandmasterPriority1 (dynamic) | Priority1 of the GM. | UInteger8 | parentDS is defined in IEEE1588-2019 spec. [42] | +| parentDS.grandmasterPriority2 (dynamic) | Priority2 of the GM. | UInteger8 | parentDS is defined in IEEE1588-2019 spec. [42] | +| parentDS.synchronizationUncertain (dynamic) | synchronization-uncertain field of the timeTrasmitter. | Boolean | parentDS is defined in IEEE1588-2019 spec. [42] | +| parentDS.grandmasterClockQuality.clockClass.clockAccuracy.offsetScaledLogVariance (dynamic) | Clock Quality attribute of the Grandmaster. | clockQuality | parentDS is defined in IEEE1588-2019 spec. Table 4 – clockClass specifications [42] | + +| | | | | +|------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------|-----------------------------------------------------------------| +| timePropertiesDS.currentUtcOffset<br>(dynamic) | UTC offset. | UInteger16 | timePropertiesDS is defined in IEEE1588-2019 spec. [42] | +| timePropertiesDS.currentUtcOffsetValid<br>(dynamic) | The value shall be TRUE if the value of the current-utc-offset and the values of the leap59 and leap61 are known to be correct otherwise it shall be FALSE. | Boolean | timePropertiesDS is defined in IEEE1588-2019 spec. [42] | +| timePropertiesDS.leap59<br>(dynamic) | A TRUE value for timePropertiesDS.leap59 shall indicate that the last minute of the current UTC day contains 59 seconds. | Boolean | timePropertiesDS is defined in IEEE1588-2019 spec. [42] | +| timePropertiesDS.leap61<br>(dynamic) | A TRUE value for timePropertiesDS.leap61 shall indicate that the last minute of the current UTC day contains 61 seconds. | Boolean | timePropertiesDS is defined in IEEE1588-2019 spec. [42] | +| timePropertiesDS.timeTraceable<br>(dynamic) | To indicate that timescale is traceable to a primary reference | Boolean | timePropertiesDS is defined in IEEE1588-2019 spec. [42] | +| timePropertiesDS.frequencyTraceable<br>(dynamic) | To indicate that frequency determining the timescale is traceable to a primary reference; | Boolean | timePropertiesDS is defined in IEEE1588-2019 spec. [42] | +| timePropertiesDS.ptpTimescale<br>(dynamic) | True, if the timescale of the Grandmaster PTP Instance is PTP and FALSE otherwise. | Boolean | timePropertiesDS is defined in IEEE1588-2019 spec. [42] | +| timePropertiesDS.timeSource<br>(dynamic) | This attribute indicates the immediate source of time used by the upstream timeTransmitter. | ENUM<br>IEEE1588-2019 Table 6 – timeSource [42] | timePropertiesDS is defined in IEEE1588-2019 spec. [42] | +| portDS.portIdentity<br>.clockIdentity<br>.portNumber<br>(static) | PortIdentity attribute of the local PTP Port on which upstream timeTransmitter has seen. | portIdentity<br>(clockIdentity, portNumber) | portDS and portIdentity are defined in IEEE1588-2019 spec. [42] | + +**Table H.4-3: ORAN defined E2e sync monitoring attributes/datasets** + +#### H.4.2.1 Datasets detailed description + +##### H.4.2.1.1 ptpTimestampRecordDS + +ptpTimestampRecordDS contains information of the raw PTP timestamps used in the node for calculating the offset from the TimeTransmitter. End-to-end sync monitoring, the raw timestamps data can provide a crucial insight into the performance and health of the synchronization network. + +CMS can use the four PTP timestamps t1, t2, t3 & t4 derived from the event messages to derive the Packet Delay Variation (PDV), upstream and downstream delays between the timeReceiver node and the timeTransmitter node in the network. CMS may use the tools to plot a graph using the timestamp information exported from the node and see how the PDV, forward and reverse delays are varying over time. + +For example, in a synchronization chain of nodes, if a particular node is reporting a high correction field value, it could indicate network congestion in that particular node or the node either lost the synchronization or changed its time base. + +Each record consists of the following members: + +- updateFrequency +- numberOfRecords +- timestampInfo (List) +- index: index/key to the list. +- timestampRecord : + - recordTime + - messageType + - t1Sec + - t1Nsec + - t2Sec + - t2Nsec + - sequenceId + - corrField + - pathDelay + +###### • **updateFrequency** + +Sampling interval, in seconds, at which the timestamps are recorded. A low sampling interval can overload the system, so discretion is advised in choosing this periodicity. Recommended value is 10 seconds which means exporting the timestampRecords every 10 seconds. + +For example in a ITU-T G.8275.1 [1] profile based deployment, there are 16 Sync and 16 Del-Req messages per second. + +###### • **numberOfRecords** + +Number of valid timestamp records exported at this interval. A value of zero means the node is not exporting timestamp record information. A non-zero value represents the number of timestamp records exported in that particular interval. + +###### • **timestampInfo** + +This is the list of timestamp records. + +###### • **index** + +This is the index or key to the list of timestamp records. + +###### - **timestampRecord** + +Each timestamp record consists of the following members: + +###### **recordTime** + +System time at which the measurement was recorded. This is essential since CMS needs this data to correlate the timestamp info across the nodes in a synchronization chain. + +###### **messageType** + +Used to distinguish between the Sync or Del-Req event messages. + +###### **t1Sec** + +Seconds portion of the PTP origin timestamp of the Sync/Del-Req messages. + +###### **t1Nsec** + +Nanoseconds portion of the PTP origin timestamp for Sync/Del-Req messages. + +###### **t2Sec** + +Seconds portion of the PTP receive timestamp for Sync/Del-Req messages. + +###### **t2Nsec** + +Nanoseconds portion of the PTP receive timestamp for Sync/Del-Req messages. + +###### **sequenceId** + +Sequence Id of the corresponding Sync/Del-Req message for which the timestamp is recorded. + +###### **corrField** + +Correction Field of the corresponding Sync/Del-Req message for which the timestamp is recorded. + +###### **pathDelay** + +This is the TimeTransmitter to TimeReceiver delay in case of Sync message and TimeReceiver to TimeTrasmitter delay in case of Del-Req message. It is calculated as : +(ReceiveTimestamp – OriginTimestamp – corrField) + +##### H.4.2.1.2: allTimeTransmitterDS + +allTimeTransmitterDS contains all the remote TimeTransmitter's information as seen by a node. This includes the selected timeTransmitter information as well. This dataset is primarily derived from the received announce message from various timeTransmitters. + +Additionally the localPriority attribute needs to be referenced from the portDS dataset using the PTP port-number. A localPriority is configured to a PTP port of the clock and it is used in A-BTCA. + +Each entry of the allTimeTransmitterDS contains below members: + +- parentDS as per IEEE 1588-2019 [42]. +- timePropertiesDS as per IEEE1588-2019 [42]. +- portDS.portIdentity as per IEEE 1588-2019 [42]. + +##### H.4.2.1.3: isSupported + +isSupported attribute specifies whether the End-to-end sync monitoring feature is supported on a given node. It's a static boolean attribute where a True value represents the node supports End-to-end sync monitoring feature. + +Once the connection between a sync node and CMS is authenticated, the CMS queries for this attribute and considers the node for End-to-end sync monitoring only if a value of True is received. In case of False, CMS will not process the End-to-end sync monitoring attributes from that node. + +##### H.4.2.1.4: supportedVersion + +This supportedVersion is to track the change in the End-to-end sync monitoring Dataset/Yang attributes as the synchronization monitoring requirements continue to evolve. + +Due to enhancements in PTP protocols/profiles, new dataset members might be added in End-to-end sync monitoring hierarchy. Similarly, when new requirements being added for the static and dynamic analysis models, this version number will be incremented accordingly. + +The supportedVersion starts from 1. Refer the section H.4.3 Yang Data M for additional details. + +##### H.4.2.1.5: extendedDeviceType + +The defaultDS.deviceType defined in the ITU-T 8275.1 [1] and ITU-T 8275.2 [3], covers only ITU-T specific PTP clock device types. It does not cover ORAN defined clocks. + +The extendedDeviceType dataset member is added to represent the non ITU-T clock types. A default value of 0 for this dataset member means that clock node is ITU-T clock type and not an ORAN defined clock-type. + +The value of extendedDeviceType dataset member is a non zero, then the defaultDS.deviceType attribute will be ignored by the CMS system and extendedDeviceType dataset member shall be used to identify clock type. + +| extendedDeviceType | Enumeration value (hex) | +|----------------------|-------------------------| +| Not-Applicable | 0x00 | +| O-DU-TimeTransmitter | 0x11 | +| O-DU-BC | 0x12 | +| O-DU-TSC | 0x13 | +| O-RU | 0x14 | + +**Table H.4-4: extendedDeviceType enumeration value** + +##### H.4.2.1.6: timeSinceCurrentClockState + +Time elapsed in current clockState in seconds. This is used to get the clock stability of the node. This will reset to zero whenever the node's defaultDS.clockMode changes. + +### H.4.3 Yang Data Model reference + +End-to-end sync Monitoring uses Yang Data model for telemetry attributes. + +To ensure compatibility, both the CMS and synchronization nodes must adhere to the same specific version of the YANG data model as outlined in section H.4.3.1. + +#### H.4.3.1 End to End Sync Monitoring: Yang Data models: + +For this revision of the specification, to support End-to-end sync monitoring every node in the synchronization chain needs to support all yang data models from various standards listed below. + +- P1588e +iee1588-ptp-tt.yang (Yang file revision 2023-08-14)[44] +<https://github.com/YangModels/yang/blob/main/standard/ieee/published/1588/ieee1588-ptp-tt.yang> +- ITU-T telecom profile yang data model. +IT-REC-G.7721.1 (Amendment 1)[43] +Section 8.1.1 PTP telecom profile YANG data model +[G.7721.1 v1.0.08 YANG.zip](#) +itut-ptp-tt-telecom-profile.yang +- End to End Sync Monitoring yang data model. +Refer the “Table H.4-5: Yang data model revision and supportedVersion mapping information” to identify “End to End Sync Monitoring yang data model” file applicable to this version of the sync specification. + +The supportedVersion (section H.4.2.1.4) denotes the version of the ORAN End-to-End Sync Monitoring YANG data model. + +The End-to-end Sync Monitoring YANG data model is implemented by both the CMS and synchronization nodes, each adhering to a specific version of supportedVersion. + +The supportedVersion is linked to the attributes specified in Table H.4-2 and Table H.4-3. Any updates to these tables that result in the addition or removal of an attribute/dataset member, or a change in a dataset member’s value field, must increment the supportedVersion by one. + +The updates to the description field or typographical changes that do not affect the handling of YANG dataset members in the CMS shall not necessitate a change in the supportedVersion for the published YANG file. However, the revision date in the YANG file shall be updated accordingly. + +The Table H.4-5: provides the mapping of published Yang data model revision with supportedVersion, including the revision date. + +| Yang revision Date | SupportedVersion | Yang file name/Link | WG9 sync Spec reference: | comment | +|--------------------|------------------|---------------------|--------------------------|------------------------------------------------------------------------------------| +| NA | 0 | NA | NA | Streaming node does not support End-to-end sync monitoring feature/Yang data model | + +| | | | | | +|---------------------------|---|-------------------------------------------|-------|---------------| +| 21 <sup>st</sup> Nov 2024 | 1 | o-ran-e2e-sync-monitoring@2024-11-21.yang | v6.00 | Initial draft | +|---------------------------|---|-------------------------------------------|-------|---------------| + +**Table H.4-5: Yang data model revision and supportedVersion mapping information** + +### H.4.4 Yang Tree + +``` + +module: o-ran-e2e-sync-monitoring + +augment /ptp-tt:ptp/ptp-tt:instances/ptp-tt:instance/ptp-tt:default-ds: + +--ro o-ran-e2e-sync-monitoring-ds! + +--ro is-supported boolean + +--ro supported-version uint8 + +--ro extended-device-type ptp-extended-device-type +augment /ptp-tt:ptp/ptp-tt:instances/ptp-tt:instance/ptp-tt:current-ds: + +--ro o-ran-e2e-sync-monitoring-ds! + +--ro time-since-current-clock-state uint32 +augment /ptp-tt:ptp/ptp-tt:instances/ptp-tt:instance: + +--ro o-ran-e2e-sync-monitoring-ds! + +--ro ptp-timestamp-records-ds + +--ro update-frequency uint8 + +--ro number-of-records uint16 + +--ro timestamp-info* [index] + +--ro index uint16 + +--ro timestamp-record + +--ro record-time uint64 + +--ro t1-sec uint64 + +--ro t1-nsec uint32 + +--ro t2-sec uint64 + +--ro t2-nsec uint32 + +--ro sequence-id uint16 + +--ro cf uint64 + +--ro path-delay uint64 + +--ro message-type message-type + +--ro all-time-transmitter-ds + +--ro time-transmitter* [index] + +--ro index uint16 + +--ro parent-ds + +--ro parent-port-identity + +--ro clock-identity ptp-tt:clock-identity + +--ro port-number uint16 + +--ro grandmaster-identity ptp-tt:clock-identity + +--ro grandmaster-clock-quality + +--ro clock-class identityref + +--ro clock-accuracy identityref + +--ro offset-scaled-log-variance uint16 + +--ro grandmaster-priority1 uint8 + +--ro grandmaster-priority2 uint8 + +--ro synchronization-uncertain boolean + +``` + +| | | | +|----|--------------------------------|----------------| +| 1 | +--ro time-properties-ds | | +| 2 | +--ro current-utc-offset | int16 | +| 3 | +--ro current-utc-offset-valid | boolean | +| 4 | +--ro leap59 | boolean | +| 5 | +--ro leap61 | boolean | +| 6 | +--ro time-traceable | boolean | +| 7 | +--ro frequency-traceable | boolean | +| 8 | +--ro ptp-timescale | boolean | +| 9 | +--ro time-source | identityref | +| 10 | +--ro port-ds | | +| 11 | +--ro port-identity | | +| 12 | +--ro clock-identity | clock-identity | +| 13 | +--ro port-number | uint16 | +| 14 | | | \ No newline at end of file diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0214fd4a428b1e4b3ab647d4fc8e18e3_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0214fd4a428b1e4b3ab647d4fc8e18e3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b0b5912dd4fb7c8b4f121d63c9e68698bceadef7 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0214fd4a428b1e4b3ab647d4fc8e18e3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fa2cc8e1b81e5377d1176eabb8536210b34b7a11816c1fd6441955e9ecd0736d +size 18593 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/04687923551fa2e922c3fd885713b072_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/04687923551fa2e922c3fd885713b072_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3739222c4b6dbcaa184bb576edde46fa24d70a2a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/04687923551fa2e922c3fd885713b072_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c410a5267a5388932c10f04282d12c6349b9da6c63e59b7f01908a55a32b1d57 +size 74719 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/05d0abedf36115f32c97f12aa3771df3_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/05d0abedf36115f32c97f12aa3771df3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..742b6803e597c92c2b5737d137639409d2f802ed --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/05d0abedf36115f32c97f12aa3771df3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:45cd22baf14f5cc9768c256cb4921ccbb6f8c7dc93a43eb7d5c0f485133559cc +size 42003 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0970dcee2196132ae81eb0bc460dfa9b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0970dcee2196132ae81eb0bc460dfa9b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1b3475b9dbd2023bb5c4a31d8f65d8bc8e64723b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0970dcee2196132ae81eb0bc460dfa9b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9948238db52eea95d2502542474620b9ffef0af5cde4e6d8a044709b41db3e8 +size 62049 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/09edf50d80d00c87f36b83756b9a658a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/09edf50d80d00c87f36b83756b9a658a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e17563c32a437e7b3c75450da9d187f2d36a25fe --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/09edf50d80d00c87f36b83756b9a658a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d112630d1642991d8ff3b91bc9861ddd109c27a0372b0f24e7f52fd0e27ac4c6 +size 37465 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0b7b74ebde9a2cd1c680ac6c43c6b594_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0b7b74ebde9a2cd1c680ac6c43c6b594_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9d27dac19104937c9d1b22363c503b974e06bbce --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0b7b74ebde9a2cd1c680ac6c43c6b594_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e86d31302de2623a9da58c0df7684bf4ac15a201f5fd46bead925b9d0be16567 +size 43283 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0c52b03c91109a1a63a3bb0016116bc4_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0c52b03c91109a1a63a3bb0016116bc4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..80b6f39626c863b73c4e0b5671a3045a1660fe5c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0c52b03c91109a1a63a3bb0016116bc4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dba367989e4c8ba859e26c86fe71d6292fb93ce2d97df78700f58acfa71050cd +size 30107 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0cd69b579e669d40e6e0ce6b4b6bd6d0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0cd69b579e669d40e6e0ce6b4b6bd6d0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c84985ea63096ff87feebadd6ddc1837af48ad1a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0cd69b579e669d40e6e0ce6b4b6bd6d0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:280a31b3d091fe38d0751173e4f6a77540b4406fc8c0b2fcc3f90bab168cd7df +size 30386 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0d30ac15d614bcd275c2e60ae11cea65_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0d30ac15d614bcd275c2e60ae11cea65_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e0528a17b2d1c9db0f0765808a1ece1a669faca2 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/0d30ac15d614bcd275c2e60ae11cea65_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:49ec7b7b6fff047f32194c671688187df5f8ab696a8e072b1b17630cb23f6b46 +size 36475 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/11fc8dc6585cff5a0e2a0eb7a415daaa_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/11fc8dc6585cff5a0e2a0eb7a415daaa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cfc91602df532eb8dd7c456cd896a23fc399f9ba --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/11fc8dc6585cff5a0e2a0eb7a415daaa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:50bd6587a045ee33227545ba4167ed2f00590edca9996c440317c2dd763fc4a1 +size 39243 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/1a5e6b7aa43e92eeb959730af7368631_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/1a5e6b7aa43e92eeb959730af7368631_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..005e492d8423d5fd0c3f8f493979871fbbf39b99 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/1a5e6b7aa43e92eeb959730af7368631_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:03cad33ce154cd31b5eace5c4611f6f6089526a9e17a09fbb9e963f38cbbe139 +size 46973 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/1c4d5f30325062ca1f139ed59ca187c0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/1c4d5f30325062ca1f139ed59ca187c0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..22191197cbc5b862b88737c25977677e06ae9b8e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/1c4d5f30325062ca1f139ed59ca187c0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5bc9f9de2dc6532155d587699f194f008eb23670ed248ad294d428a909c2a278 +size 68889 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/1ca583c2983f90cd6f131dcd1fd15936_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/1ca583c2983f90cd6f131dcd1fd15936_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a3e473daa1d33129002f2392865c9d9eb6b9a807 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/1ca583c2983f90cd6f131dcd1fd15936_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d692f7e394b7b434c643a85927e16f2b1467432aa6fdc085473c6bfc3c5f5038 +size 37783 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/21eb1cdc2e7868206dd3b3125d0aaf36_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/21eb1cdc2e7868206dd3b3125d0aaf36_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fdd69661e17e15bb2fce82d7995af510289dcbc8 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/21eb1cdc2e7868206dd3b3125d0aaf36_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7baf2ca77c5e488fb17d6710f6a18c018075c63e8e75add28da2af55b8c266ba +size 46912 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/225a45855711c01be0ebdf272e6e6968_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/225a45855711c01be0ebdf272e6e6968_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4ebab5d4554e5f21e71fcea3643900e4e56cf908 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/225a45855711c01be0ebdf272e6e6968_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d5294ddcbd4475852b139a11c58844867d1fc82f7e3c130aa62392bceb035ee2 +size 75389 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/22b4c62f1e3935cd4fd9c6d19d42d08f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/22b4c62f1e3935cd4fd9c6d19d42d08f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e259da75bd9eb801227626c528950872cbbbdc53 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/22b4c62f1e3935cd4fd9c6d19d42d08f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a3897a4851816620410930593b8fe403259c1d047c0a0cb08f2242e8b0c39401 +size 57011 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2346f80f0aa7633e2988b39e02263ad5_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2346f80f0aa7633e2988b39e02263ad5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2c4924f6f6f1b8bb1026b6573230942d24902682 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2346f80f0aa7633e2988b39e02263ad5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d12d37ac2dbe54dbdce66b4ed2b4f65de775fa066b954c5a6716125e880fe36b +size 29308 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/25e96b2765418f1b55faed3e8825f30a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/25e96b2765418f1b55faed3e8825f30a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..92477032c03c4c8dd8fe688cfa660a839ed8f339 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/25e96b2765418f1b55faed3e8825f30a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:14f47889bf1771b31abe2562bdf15fd701f5151cacae74d9751c36fb6829c492 +size 38009 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/27d1de573ca1b667211a0b0e851ad52e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/27d1de573ca1b667211a0b0e851ad52e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..245c0706d68682e8e958dc0899f5f631a2de48dc --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/27d1de573ca1b667211a0b0e851ad52e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fe2b073e0b1a5130b701bf5b46a6da4742107ad7d5f07ef51ea0d5244bfd62fa +size 30990 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2a1e11e72514e1c921f1644e65f39059_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2a1e11e72514e1c921f1644e65f39059_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a0fa4de0cff45dda6182ab23a17a1b4385dfeea5 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2a1e11e72514e1c921f1644e65f39059_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d27afd3a3055153d47f4873addcdb5382ac36c3677ba2d5d06456597eb86dc79 +size 61112 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2dd711da7aa0ecebf64ad7b83325da13_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2dd711da7aa0ecebf64ad7b83325da13_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a5b009cb0b2b6ecf03c4ee69193930e14a65b2b8 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2dd711da7aa0ecebf64ad7b83325da13_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e3a33fbe4179c8b879984f6870aa192f644a97ae655ef88d14b4329221d9777e +size 53584 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2e906baeab07d760989400bfd3215338_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2e906baeab07d760989400bfd3215338_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c6f4370f0c649feb9ac443a02f9573e0e5465034 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/2e906baeab07d760989400bfd3215338_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3e7a33f34eda8b49e0deef048e08c61bf4e31257c94662c6b87247d4c2dbd8c3 +size 17253 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/305ce8e9bc20b9d86576301d96af015a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/305ce8e9bc20b9d86576301d96af015a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5f6607ca58d85d1b915f83759732ab1515218396 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/305ce8e9bc20b9d86576301d96af015a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:828fac4d820933249096b4f1db5885f97d1d4b2546f22528241ea7d71141280b +size 75905 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/30d4c28df95d6b1e4152bc5aa3378335_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/30d4c28df95d6b1e4152bc5aa3378335_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8e0329c95daef2f33288680ba0adab2474f8f446 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/30d4c28df95d6b1e4152bc5aa3378335_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:396e9fde0c9628c00dfb682447421dca4e231a34140e6b4fbf3c0e38c627b362 +size 65435 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3261ca490d9efeff7ce47e69b30a181e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3261ca490d9efeff7ce47e69b30a181e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f09288ec8b34cc61a2b45bb78bee12e6551e344b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3261ca490d9efeff7ce47e69b30a181e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:129d1c8cb3169c94404bee57c76079dfe0e1c7f156f1f03bcb664c1fe0745227 +size 29114 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/332615ee8041c456b47322dfe7300316_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/332615ee8041c456b47322dfe7300316_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8016840eeb774f59c3dccf0c9f50afa9912c41c2 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/332615ee8041c456b47322dfe7300316_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:60bc84813ad784244962941d2735144b17f152d6b7b254ae1f10212076710738 +size 21083 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/35ee0e15a1f76635bd440b1dc1bea31d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/35ee0e15a1f76635bd440b1dc1bea31d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ad78684c93d32559f0a191d19147ccd700a9772c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/35ee0e15a1f76635bd440b1dc1bea31d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1fb7f1533b794953ab50fdc7d837db59ef4956c26dd1bb22711a23c02dfd7a20 +size 60127 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/378dfcf67149d76177e41ba9e649fd14_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/378dfcf67149d76177e41ba9e649fd14_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fd7b2f28dfb9297c0364d21c069dacf7059e024f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/378dfcf67149d76177e41ba9e649fd14_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:391774d7ce313dbb18f33bd949d20412976ec8be65f0aa5170140dc00abac394 +size 42606 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/399ad7bd558d674e3ea1b07456a91e3c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/399ad7bd558d674e3ea1b07456a91e3c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8077d6319f4bf669ffe7b4ae817f593262c437fb --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/399ad7bd558d674e3ea1b07456a91e3c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b0bbf1fc2d39f3656053cfd6c48ac8beba2d454da6c2487f57e1c1cd4e1437ea +size 17003 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3a36142be9c4750b8396bcb25f1138b3_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3a36142be9c4750b8396bcb25f1138b3_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1da29d328624969301ae74c295968713c2d43bc --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3a36142be9c4750b8396bcb25f1138b3_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:89bc7035ced126b4fc5a5868247ae2b4d3f368e89140604fee594624b4d6052b +size 62117 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3ae95fca46a8ce5dc6b4ad13ce042f6f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3ae95fca46a8ce5dc6b4ad13ce042f6f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e52c1f900980dc22b133e3fa75bb3c6675dad4e0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3ae95fca46a8ce5dc6b4ad13ce042f6f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:52c1508063e624d387290abac49b943930b1f6d89fe31628f3b3c2ddc569cc0a +size 23254 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3b43765d5e86148ee98b64e49634ac58_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3b43765d5e86148ee98b64e49634ac58_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e78141aab0fe881ad0182ef92dcae5a91b2f543f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3b43765d5e86148ee98b64e49634ac58_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:83cac13a663fdc022a04718af4ebe0c5a8bb5f834136770a429dd731cab00bd7 +size 66233 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3f557f4f67b894c2036734bf5b77af72_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3f557f4f67b894c2036734bf5b77af72_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cf318cda3c0919599974d1cdd06d958bf49330f1 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/3f557f4f67b894c2036734bf5b77af72_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9c82e4fc265a9fad9ea9aefafc22bafe2cc5cd1003d45258dd09ea71b286fdb1 +size 27273 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/43ac9db4eb883317998aa91613d7aa61_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/43ac9db4eb883317998aa91613d7aa61_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f98f4b007a40751606b282d1831327bded711593 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/43ac9db4eb883317998aa91613d7aa61_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15b27ae3d56eff2d50ba90f3166c16144844e144deb369402a736539835ecc36 +size 38318 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/46195dedae416fd1e2c032ccc57aad8b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/46195dedae416fd1e2c032ccc57aad8b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..99718af1c553fc2ad799f4050dc5065e5d679b94 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/46195dedae416fd1e2c032ccc57aad8b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3f5d91d93a75166ed8f20f7014649af57674f692c4605e170f47f8735c4391b8 +size 61830 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/47cbca4aa302f4f5ae38673c651e1d36_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/47cbca4aa302f4f5ae38673c651e1d36_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..120548358a07f7ef8e8605d6c5df7608ffa93910 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/47cbca4aa302f4f5ae38673c651e1d36_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:117155605c4c529eba5112ff2cdc1fb15b9269dd0b0064f27854cffdf07fba4d +size 30716 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/48ce318f03f17fe720ef0d72f05be128_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/48ce318f03f17fe720ef0d72f05be128_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d1da68dab5462f1c7b0cfcc8a864ecbf714525a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/48ce318f03f17fe720ef0d72f05be128_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6c98e51422cccff378c7db07587bc7722a5941a0ed845e9dc2e49545b2364988 +size 57791 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4a5978aadfd00e76db821f87ccd70e6e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4a5978aadfd00e76db821f87ccd70e6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c6f6fd3c066a5fe42940a8666698546ec985661c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4a5978aadfd00e76db821f87ccd70e6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:56b274b4f975685509fa4cb64692c594fd3d461c3d9ca70ded6c2d01ed298807 +size 14073 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4af85404f97995bd13a3aeec8db30471_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4af85404f97995bd13a3aeec8db30471_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..eb9a4a753f2adc4e874f14cfd0b61af2e1144a27 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4af85404f97995bd13a3aeec8db30471_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fbc8c535807965363456885c3ce72426cc106a7a8d896efa0cf7c15d842ae60c +size 38767 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4b5691e53321f28dc4b69aa5026f2c62_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4b5691e53321f28dc4b69aa5026f2c62_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2a66e23d5cf9f2f23c28ee1577aac4ca372cc69e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4b5691e53321f28dc4b69aa5026f2c62_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9a934d3bf2707bb98ad35ddd9f7402413381675f541a4b42d7ad9a09c10e64ca +size 4512 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4f7fb52c848c2202a5d1b1d4817edf44_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4f7fb52c848c2202a5d1b1d4817edf44_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..95857e15716b99687fd4e4d0c306e0ba2cc18f19 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4f7fb52c848c2202a5d1b1d4817edf44_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3b5bd47745561bd8b9a0dad3787f3ec53ac0cfc8883a26ec0d423336839c7431 +size 84293 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4fd0af66099f1cf653113a855ff64e17_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4fd0af66099f1cf653113a855ff64e17_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c165efad81983520c7fb4757c7a5592ac87b7465 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4fd0af66099f1cf653113a855ff64e17_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3b7833b82aa983ebf693ae8cab71f66976036522011b970ab04ebab44a79c169 +size 44131 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4fdeda2d2c466b9fc167c17bced92fa9_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4fdeda2d2c466b9fc167c17bced92fa9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4973b293be643ae041c6e7ce1536e783bd820465 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/4fdeda2d2c466b9fc167c17bced92fa9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e98117385fc81520c6e1496c040147315d3986b87d207bfee0c21a2aaaab35cd +size 81814 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/5851c3b838048bc0accb6b7881aabef7_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/5851c3b838048bc0accb6b7881aabef7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e10e2751290cd2e26c192b52124de6539c022a58 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/5851c3b838048bc0accb6b7881aabef7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d66230fc255b7cb947b5ba62443eb655bb3cce3fe08859cb2651a0783696a404 +size 88348 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/5a8791c8bd300bbe0d810c8bcac2ba3d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/5a8791c8bd300bbe0d810c8bcac2ba3d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1b6e78fe505b17e7baf0f93bb92a0a94a323fd74 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/5a8791c8bd300bbe0d810c8bcac2ba3d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8de57c386479d293f5624d7756523e9afc1142bdbbe127499277b22409aaa050 +size 43996 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/5d194147ee7707a26492d37b08d36044_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/5d194147ee7707a26492d37b08d36044_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..474ffff0c854dc49c9929d8917c80f1975195959 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/5d194147ee7707a26492d37b08d36044_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ffc63ca884277740f4479a80929afa3368bef0e333a7e53081ffc9f36d28070 +size 21170 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/601ca86786424c6b19e1f99f315b4e1a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/601ca86786424c6b19e1f99f315b4e1a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..20498f5f915d10e4aabc1aaa098aa890f15ae0a2 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/601ca86786424c6b19e1f99f315b4e1a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:581e5b385e26975ce301917c5c63664d6fadef8b92bf07ee1c3b91a3d11805a1 +size 33626 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/6b454ccf699bd029eab0e84d692716fe_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/6b454ccf699bd029eab0e84d692716fe_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..36e2f5b188c74a52b69fa0365031d5f308af8cf9 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/6b454ccf699bd029eab0e84d692716fe_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:00c42af9dc2b14d8f28259a09089234faa43e1886beade0ce95f8317b1149b5a +size 26306 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/6d940bb6c9a1ab31f74f537dc458b573_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/6d940bb6c9a1ab31f74f537dc458b573_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..011cdca02e7f5f078cb2a5b5b97b779cfd6b4b89 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/6d940bb6c9a1ab31f74f537dc458b573_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ea5cf972a56d96c0eb368421200e78c0114525fe66fd8aa72b302b2748131cd5 +size 44695 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7137438ef8e467d696f2bfa51e3ed113_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7137438ef8e467d696f2bfa51e3ed113_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..300ad4cf17e8e31efd381ecf21e11785bb60a75f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7137438ef8e467d696f2bfa51e3ed113_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5f46567ea7166a49278592d9d3334ac566e657bf7cd266b9fdc33c59cb19555c +size 68929 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7457399ce2e6c08f79bdef5fabb2085c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7457399ce2e6c08f79bdef5fabb2085c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2b54abfac06d4c8c303d388237061a9a3aae40f0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7457399ce2e6c08f79bdef5fabb2085c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:94390030371af20ea4907796722ab40224c2b174163d135e317676e183343752 +size 40467 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..27225d0aa300adaafdd4117dedc67749d0a1a206 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/74e57a5ee96f5b41ee4d2633cac0cd8c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48cf233b970eeaabdd503be04bfc1c953c2305a08074046287524dfb5e1dcd7c +size 4522 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/771f139f2283195791994107a5e1e6db_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/771f139f2283195791994107a5e1e6db_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..172198b77e11849ba9461e578d7e87afbb51b970 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/771f139f2283195791994107a5e1e6db_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:05d1d1fc6dea92d81837cc2aa2d4c368d4604abe9b99c207ca2717b3bc33933e +size 23129 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/77b81b63aaf6597a4b7098c9d10c686e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/77b81b63aaf6597a4b7098c9d10c686e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..14d460c5c803822960f1822a8b02c87a4997e1b3 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/77b81b63aaf6597a4b7098c9d10c686e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4efc4072eb027f0fbbeaf56869662b108bf1d0e058a9efe76b79a73428dfbc4c +size 37447 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/77f037e0a627c6188175167f6dd84148_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/77f037e0a627c6188175167f6dd84148_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..04c459fa13189106903398de9f1cdd776ad707a9 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/77f037e0a627c6188175167f6dd84148_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5a3543accf63e4267bc07a434b43a566221b561e93a98978c45d2b9bd96b420e +size 113102 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/791cc4558f31eae5cc1aaeb5246fed89_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/791cc4558f31eae5cc1aaeb5246fed89_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8c453bb039a62a974c9ec2f871bb898e40ae1e5a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/791cc4558f31eae5cc1aaeb5246fed89_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bb08d2ddc18de39ce16c6d5e9068412a704ff919621109944809bdf114dc100c +size 51285 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7a979cd806a799070d18d98391c0fe12_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7a979cd806a799070d18d98391c0fe12_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..71640152564a1cc2c664852e67309ba4d03cf411 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7a979cd806a799070d18d98391c0fe12_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c1c077388fc25b50056257b3df5d56fc1c50d11e5d2aac5160db0601642b798d +size 37963 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7c36a66dce4bcf2a43291f6a814835ca_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7c36a66dce4bcf2a43291f6a814835ca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..72b256aeabb4f0d709d40ca7cad8ff1a42ec9d49 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7c36a66dce4bcf2a43291f6a814835ca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:264979bbaddd11afc2667d480b98e0f00d42ec964e67fcefaf34f647b4754b6b +size 19537 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7c774c70315893c49a2e5393b9c46165_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7c774c70315893c49a2e5393b9c46165_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..45d76863dd45308ff9556fd366de7e2981ae86be --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7c774c70315893c49a2e5393b9c46165_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:89160e1310b7b3e018165a04af7ad5de650a8dd61c96dd8e054f5f22e01588e6 +size 26968 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7f179a39e169f8b9413d1d1b77cc61a5_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7f179a39e169f8b9413d1d1b77cc61a5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b455480daa05a9611e87acecb2f868dfa582f5fa --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/7f179a39e169f8b9413d1d1b77cc61a5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:87f6e3e7f6166a775d23eb2935fe2394dee898004a151b068d8ee3d07853427e +size 67571 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/85333c683b8a4799eaaa0ffaaf2f5f8a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/85333c683b8a4799eaaa0ffaaf2f5f8a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..71cdf414c200b17746845ef8877880d0072ddb52 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/85333c683b8a4799eaaa0ffaaf2f5f8a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5f623edf912b537bd948c346990a46fb501f9e231992a275c6a81646a762296c +size 38098 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/862365b7aea340b13f9b928757c8ffb8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/862365b7aea340b13f9b928757c8ffb8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c35a8a1664f161654a6b6f888432d425b572e47e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/862365b7aea340b13f9b928757c8ffb8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:edeba70d70c9b398be8f6d7015bb0a97d16aa72fd932723d9f5a2ef6c82fc83e +size 37388 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8670a4ef771d8f3c3a7082cece1c3fb4_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8670a4ef771d8f3c3a7082cece1c3fb4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f2cae96522f9146772957851435a1706e30aaf55 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8670a4ef771d8f3c3a7082cece1c3fb4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7a7be0acb40a5bbda1f2138b658ab4e1643814b6f1d55dcb654021009da381ce +size 37856 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/884b5829d73878527df431d14696730d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/884b5829d73878527df431d14696730d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6470b5d4560cc45ba0366c8708adf2e9bc938e86 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/884b5829d73878527df431d14696730d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fbb28bed7d3edef5765f19c11f78008c671e677bc4d8a092039afdc84678cff2 +size 37276 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8a682c8df87944123ae36898b25a5a7d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8a682c8df87944123ae36898b25a5a7d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5076d170108ed01af93a9998b6cedcc6d9afd10c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8a682c8df87944123ae36898b25a5a7d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1287d5244018998083be42e97ca148156d858474ebdba03d1f9a5b2ed1b54798 +size 13685 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8c91cfc2ea1cf69527842107b7d5e027_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8c91cfc2ea1cf69527842107b7d5e027_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6bdb1c840641227475e9637d62bab02daf7969a8 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8c91cfc2ea1cf69527842107b7d5e027_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6c068d7afc7e7b5d43389fc642f3d3eb41ab9de301a89453d4c24431dff88b04 +size 63317 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8ca6fefa61e09ce8031ca848f970da94_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8ca6fefa61e09ce8031ca848f970da94_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4d1f4d46d7173f03cbd04052855697e1f1f9c084 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8ca6fefa61e09ce8031ca848f970da94_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:62a5e83fb59da88b3d7f5b16de1c39919fbe8559bc5f2715545cb745336ba75c +size 28117 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8df97f43bb4b250b1d647bd375155e5a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8df97f43bb4b250b1d647bd375155e5a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..99d51db6a2c18dcbe6bcc1f561696a4e371a21f0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8df97f43bb4b250b1d647bd375155e5a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ecb2d471360b4d468ad5d5c8340c5d4addd77780d4445c6363b69978de3c22e +size 4544 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8ec5843787e762fffcc9a448d841fb26_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8ec5843787e762fffcc9a448d841fb26_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e17575083847b0de2b5dbb645893b4b3b4f7dc28 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/8ec5843787e762fffcc9a448d841fb26_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7eff645c5d682be0c2c2730d84c2f31a79cb63d8a77041eccd85f80e995a35a0 +size 42356 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9082fdc6e1af8f33c92b9f0904427246_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9082fdc6e1af8f33c92b9f0904427246_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9199bee0993aabaa9cb682d2bffd586b216cf135 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9082fdc6e1af8f33c92b9f0904427246_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d3f2b8349697a063ca53b760f486978bd2cc5adb1c68831fbd6fdf9d7cdfe2b0 +size 67592 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/90d97add5992a9d4038ffc88c115bbb1_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/90d97add5992a9d4038ffc88c115bbb1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c17c37e38da8d1232bf8f7af5aae9fbf5f0a5989 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/90d97add5992a9d4038ffc88c115bbb1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7abe710a91ba5c9d73347c4d632dddb83c329e22f883473b3cb72a26d67a2c30 +size 51475 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/91fd388c9905d32d03f616187259e27f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/91fd388c9905d32d03f616187259e27f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..df5e93fc31017425d4ff140b5e185657554093d6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/91fd388c9905d32d03f616187259e27f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7d1b4f6d566c1d636217bf84ee5b179e6f646c072b46b800e606221a1277e63a +size 44094 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/94dc926f52737014cf46c0833bd36cf7_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/94dc926f52737014cf46c0833bd36cf7_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8b4eb671002cad149a2b1b3005fe4b558fd426e8 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/94dc926f52737014cf46c0833bd36cf7_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4d08960871154a8d68d480416423f955c4554db2d02a08b51dd7599a2017a64a +size 43018 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/988a0c7087d0989cf2a0bb2ed500b9d0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/988a0c7087d0989cf2a0bb2ed500b9d0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..157b3447acf137b5f4e301f2c4e3e96497ae923b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/988a0c7087d0989cf2a0bb2ed500b9d0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:97415ddedb6da49b5185dd943d05d0f27ba4aec4258657b1c9c95c45c29679d2 +size 28865 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/99e3ecf377ea9aee9f26bae1fab933f0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/99e3ecf377ea9aee9f26bae1fab933f0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a02a327534eb94d50cab0f3bb135a904536b18fb --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/99e3ecf377ea9aee9f26bae1fab933f0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c8ea023e26c51a827e318e5fb7ae277855986c44401f1e9ecc6f1c91a63fbc4b +size 4601 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9c7a41a4a0c7558cfd63db5f0bc20005_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9c7a41a4a0c7558cfd63db5f0bc20005_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..965f09d4b24cd55d0c5755a60c602a4df6f53f2a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9c7a41a4a0c7558cfd63db5f0bc20005_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:abf633badb721212962be19f27d63113c73ec12d76a4487e627c2133747ff3ea +size 42964 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9e5b68d600d5777a5312a476134ed3da_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9e5b68d600d5777a5312a476134ed3da_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6816ae00b42bb461081f529fc0b7d7debe6dde97 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9e5b68d600d5777a5312a476134ed3da_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f697ce515b6a0a2019ca566a37c9591369cdeef110307f8e34d13be5d15329e5 +size 38268 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9e727d0cdf88eca9085ecd457b33dafa_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9e727d0cdf88eca9085ecd457b33dafa_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cdb699de78b2cbdbb6c376fe8bb4e7d59dd04c0d --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/9e727d0cdf88eca9085ecd457b33dafa_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0f296b737b96edc1c67f302d7cd5627f0f296cc5effc25e0ec897b43521e071c +size 37381 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/acc0e87c785d6661f82604905385a7a4_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/acc0e87c785d6661f82604905385a7a4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0308209bff3ee76c91f3689860594ceae099a7c4 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/acc0e87c785d6661f82604905385a7a4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3d07548ba2a1127903c3ff70df4b340f9bac47c9e4e5ebdbd6f0de42fb4babec +size 44728 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b016ec57d20d073d4cba849c140ae5cb_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b016ec57d20d073d4cba849c140ae5cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4ba88f20d51fb1e78cef4698b0cbf11bd6378059 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b016ec57d20d073d4cba849c140ae5cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1766091b39239d4910fa255a3ad9e9db729386fbc00858fe3a71ee70c7d7f8ae +size 67918 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b023d5c06190e42e864d466d8fb5c9d4_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b023d5c06190e42e864d466d8fb5c9d4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ffc26728d2420145224b40660da6d75b47bc23e2 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b023d5c06190e42e864d466d8fb5c9d4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d01b0e55c2106b26f6a207fb9241ba0724f212697f40614bdca403c52b9ced15 +size 31242 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b06e9e3bca7dc02d69312e98185e7672_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b06e9e3bca7dc02d69312e98185e7672_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e8103a50d3c48e9356dd950731ca46e431017e6e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b06e9e3bca7dc02d69312e98185e7672_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:42ce1f35127df8f2efb85a6ebbb49b7816297c3328d574acc48cd5ec22497dd6 +size 13193 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b116ae1f761a81b34f7d992965fe41c2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b116ae1f761a81b34f7d992965fe41c2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b91dd1b55b402690a73242b9cf726a14ad712ac9 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b116ae1f761a81b34f7d992965fe41c2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3d50f5e6b84b4ce15095a37a127d5b256bee7cd94c4cc87d42fa853131cbaf78 +size 44083 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b1da9df21a4d28b51bccbfa46c00916e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b1da9df21a4d28b51bccbfa46c00916e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ee11c8107f837bede332d195a2ec0a795a86950c --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b1da9df21a4d28b51bccbfa46c00916e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8cc6b42cceba04e145abb46cdaae2e079fcb7b9e4fb50fc43a7996a013cddba +size 27325 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b22bbbefce73426dd810cd25259ab6bb_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b22bbbefce73426dd810cd25259ab6bb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..05e633e57963277a8c349719654afda98c155090 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b22bbbefce73426dd810cd25259ab6bb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:528aba5dd1e27b9f75ab8211ac57028f76413359b55621b21332f38a99cfb1f2 +size 59011 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b2e11efbd210f9f675c1f45d001ab48e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b2e11efbd210f9f675c1f45d001ab48e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..765c358fcdd8b29be6aeda212f951fb8336fa5ab --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b2e11efbd210f9f675c1f45d001ab48e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d796cea7bf9074c3b96bf5840e2d9e4d27e8af39931c84404e48fded3873a0bb +size 46361 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b4cd7dd6811aa60c4ebd5932f18b43c9_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b4cd7dd6811aa60c4ebd5932f18b43c9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b1e68cbc7df976e555015a8a8642f30e9cf15d37 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b4cd7dd6811aa60c4ebd5932f18b43c9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:46d4c2dc5a3bea4e9d0d674de83a991b475716258c8f004959bf7aef392bbc04 +size 41627 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25c3de7eea7b3c381ecf3960d79d1fa32d1c5533 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/b6c2c007d5d4d84bf961176380e41d0e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d502c14c70a134234eb71c90497070bd25cc7f1a4365927e8843303ef34d4706 +size 4498 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ba07a2e219b5e19b46539e73a6d7d4eb_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ba07a2e219b5e19b46539e73a6d7d4eb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9a422171f8a06211d9b6072da21b6690bc7b487b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ba07a2e219b5e19b46539e73a6d7d4eb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:25760072157294b4928abacecddafaa66d4af282fe3664ff2b15d6d0ffa6388b +size 22921 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ba0d359b5273771c851dddf0e8c198c0_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ba0d359b5273771c851dddf0e8c198c0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d546ac043ec1a7145ed1eca59891b038ccdc0ba8 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ba0d359b5273771c851dddf0e8c198c0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:20b89efc703fdb0a9c8cf94aa224fa19d8057bd7fce445ea1d0c3347dc65ccee +size 31341 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ba727b73ec7c2451a5cb8f9e82f055f8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ba727b73ec7c2451a5cb8f9e82f055f8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..099ccd66e848c1c7126336c3da44d4841f66b69a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ba727b73ec7c2451a5cb8f9e82f055f8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9669f912caf12e2b20cdd8e1a641852427a9f8529fb182011cabae438ea897c +size 74556 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7575c364a05dd515d7cf096c30ffc26f8ab2631 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b321cfff0a169d11fa6daa2e14ee4667e12bcfeff34e35ee9dd80b810a6385a6 +size 4491 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/c28d2122c857d0561366e8721ee7c70a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/c28d2122c857d0561366e8721ee7c70a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..35650c9d29ea7ef95cf78985039943d45c65c1be --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/c28d2122c857d0561366e8721ee7c70a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2c793eee76bfb5469afb2f32feedd65c7d76086f84b17254acecf8899d0f578c +size 64767 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/c2f163574be3eb460ee3eb8dad3a3249_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/c2f163574be3eb460ee3eb8dad3a3249_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a8098e07ab6747dda1d3b6a623864a22b5cda970 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/c2f163574be3eb460ee3eb8dad3a3249_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:60107a9b2806db88710e36045d9e16d02391431c8ec983f93e7508fcd37e5739 +size 39116 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ca721d0a8da02016a9cf29dd1329f081_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ca721d0a8da02016a9cf29dd1329f081_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e072759a10188e455679f16e698d4d6c09c00289 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ca721d0a8da02016a9cf29dd1329f081_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3c6061ab2baaf59a57fd0faf8edbd730de538285af9b38755df1650c497eb804 +size 43455 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d1af0de88faa3c4d9f3152f936cba8ab_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d1af0de88faa3c4d9f3152f936cba8ab_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..31e41f651989a4bce8dcb06eb0dcf3ee5fbc3123 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d1af0de88faa3c4d9f3152f936cba8ab_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:72622819f6808d45b57ffda3b8b0cadcc3feaea681784324b08d86f89a87102a +size 29296 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d1d81347d5a3218401c0e51cc864e33c_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d1d81347d5a3218401c0e51cc864e33c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..418047741f96a37dbcd8136f9baf93943fb6b024 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d1d81347d5a3218401c0e51cc864e33c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9a8db5cc3bf1bb55fba0fcdd4fd5f34922cf3fa97b57053a41fb009bab92f2f7 +size 20216 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d1f701d72fab4f1cff3347d7790b844a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d1f701d72fab4f1cff3347d7790b844a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..584f55c3ba7d8eb0889781fff73a81c39cbb0eff --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d1f701d72fab4f1cff3347d7790b844a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:039d772a2d0fb5c429855772f91d65fca82676592b1af5e07257fbf3b5fa1aa6 +size 34079 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d2c91350916f33bd65522fd8db875db4_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d2c91350916f33bd65522fd8db875db4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..24fb4e8fd6ac2cb88b0b1902f1600563425bb337 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d2c91350916f33bd65522fd8db875db4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e196b405fc18a6f7e17cc1801073a0d76f60c14104b70aa790ff198860637f40 +size 97243 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d6392fb104e2e3d102295b5a9be6c50b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d6392fb104e2e3d102295b5a9be6c50b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..544b0a1d3858dcb10a4e3fb7c07211cdf58bc59e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d6392fb104e2e3d102295b5a9be6c50b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:997cea35a224d115c1d024f6ec838af9229176b60daf514e914673894f34d44a +size 66855 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d72e3817bfa42303b4c3d3039e007256_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d72e3817bfa42303b4c3d3039e007256_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ac156432a044355042dd3989f6f78ebb892142c0 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d72e3817bfa42303b4c3d3039e007256_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:55e9fbb32876a9ca15e42069958082318e8aeba5ce0829c300e1c3404b36c882 +size 63614 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d789e03a60e01679a1588818f0026e48_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d789e03a60e01679a1588818f0026e48_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..42001f8e2231e787d95a2bf281a2ae4d1fd088d3 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/d789e03a60e01679a1588818f0026e48_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1fbc00478b6c816bb1924ce9d7c8ce2c209c95cb5effcf0719ffa3b3c18c516d +size 16961 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/da9c6ad0046b59c27b6c5c81f5864932_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/da9c6ad0046b59c27b6c5c81f5864932_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1e50e8cf38116804971ee6f2af9fb92fcbdae800 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/da9c6ad0046b59c27b6c5c81f5864932_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0708b605201a4841efedfe309a8157dea432c18abf931874687354e30723f30f +size 36891 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/db4c6983f6afabb270b7cbcf12564f1d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/db4c6983f6afabb270b7cbcf12564f1d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9af6658914314e19ed22008d64a3cc0690ae23bc --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/db4c6983f6afabb270b7cbcf12564f1d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d173296a12a40782419397c446fe0a07b3deb5fa9e3683ffc250c9e17e28f000 +size 69729 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/dc614d6176386a794f6cc11a39aad90d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/dc614d6176386a794f6cc11a39aad90d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2a9e4d99fecbddedb3ae932ab4774df46e59bc48 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/dc614d6176386a794f6cc11a39aad90d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:15b4965d94aaa2b5ea81de992f4bcb171e52459792612f38175ada4548d1239f +size 34686 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e2d377a7b1ecc3d90d66455a89af93a9d69c05c2 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/dd74c873b1c7009e2ae23d8405f25a6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f53afab4ac078add52c3f0b2a3b8709940df75f38907b6df0bd3e7c4b98620ac +size 4528 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/dfa50375f581d1bb643347e6642a9b52_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/dfa50375f581d1bb643347e6642a9b52_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db15f3df13f96d8fcff4e28f4326fc6d19bbb550 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/dfa50375f581d1bb643347e6642a9b52_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:051dc7598246a628c95130c88a5d43321fd9cef76817801bfd29744f04157d39 +size 22511 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e197ca4cad293a99c3ec914651cb2642_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e197ca4cad293a99c3ec914651cb2642_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1eda178417968a00051aa4bff5006f33741ae464 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e197ca4cad293a99c3ec914651cb2642_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3bed7fe5f8b077e77e735625e13c529f71a885c048f45c180d30e02454d5570b +size 30362 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e1b881026b9f023cdb209c9e928dca04_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e1b881026b9f023cdb209c9e928dca04_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..798df646bcd89efd1fd04143f859163e9dc59ceb --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e1b881026b9f023cdb209c9e928dca04_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8f168be494861c868a3b31e153959cdfab9f1749a00b45b71d86beb154d4075a +size 46046 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e3d80fb80ea2997b0a2e2c6494d48bd8_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e3d80fb80ea2997b0a2e2c6494d48bd8_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cedc71e7ada8daec33b85888ab04128dd23822b1 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e3d80fb80ea2997b0a2e2c6494d48bd8_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f04b3ba0c7b1b9279788ef0143c29e7edeead1a9dc8bc45745bac9620b52b4f7 +size 38836 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e769c6913197653d6c181564abf75c25_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e769c6913197653d6c181564abf75c25_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..db4eb15d1e2f30dc8e950ec9a27c9890c2f0e5e9 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e769c6913197653d6c181564abf75c25_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2cb397033a75cc0be97992c32784ac2161e8e7510f8e31f7b04fc6303ed1ee35 +size 62385 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e97f0e6390a73b17968f1a103483fa17_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e97f0e6390a73b17968f1a103483fa17_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fe991346edffaeab5c14d1e01b329227d2f32d5f --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/e97f0e6390a73b17968f1a103483fa17_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c44320fddf7a6dc275f8c95dcaed43700886ec1cea7522d602b4e388ced269a +size 60256 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ec9b860f913e44cd061ba11e4b3e3c31_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ec9b860f913e44cd061ba11e4b3e3c31_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..f35c111c98609eb4ceabca8ad206fc31b393c998 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/ec9b860f913e44cd061ba11e4b3e3c31_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:4c22b333ab2a1d27bad060f3f82da670007771d98458d60a54ddf150660a33c2 +size 28426 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f0c8e72eedba6c3337fd743729a4555b_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f0c8e72eedba6c3337fd743729a4555b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..6e1bb8471c623d4458b6f1458bb81457f0229fd6 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f0c8e72eedba6c3337fd743729a4555b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:56f70eee5e077df990bf9c30071d864574babb7e81089e831f8e2756e016e6f3 +size 68575 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f11c22832f1b704bc78d6534ae671707_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f11c22832f1b704bc78d6534ae671707_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..177351ab5ef5b4ac9c28fee6595310aa3c7c929b --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f11c22832f1b704bc78d6534ae671707_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:018b00f084ea7ed43fdf85c27fd850157cebe839c4f8c5fa879c60df49e9c2a5 +size 4512 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f3f1b6d7de0937e60fc4462c4622fb1a_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f3f1b6d7de0937e60fc4462c4622fb1a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2d97c4e1a2af92df1eacec0b20d01bdbed271a26 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f3f1b6d7de0937e60fc4462c4622fb1a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:212bf434a0e3ae6e8f2817843db0636fa3e753fbd13657913f1afa7c48a0b46d +size 23008 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f6475de7113245bcca0894bcbb751e17_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f6475de7113245bcca0894bcbb751e17_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b7e09366854637b3b967c3a4c0c77e868f2af3ec --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f6475de7113245bcca0894bcbb751e17_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7a206355e9e6f87c686271bbadd045e3974bcb89a81e53701ce40fdd82f1f453 +size 59705 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f6ac527e0b1bed3f41e5989ba3e86a07_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f6ac527e0b1bed3f41e5989ba3e86a07_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..562a5fb1ec3d0d8ecf8beaabd6a069e68daca0a8 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f6ac527e0b1bed3f41e5989ba3e86a07_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:960834d21203a8a57b42a806e587080288a9c2c46ffc1b16b6a3cbe0dd016a60 +size 13561 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f6af9077a2a151d8ee733f47d57b5d1f_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f6af9077a2a151d8ee733f47d57b5d1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..48c32cb449ba17766ef23cec154b65d52d2d60e2 --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/f6af9077a2a151d8ee733f47d57b5d1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:26a1f29923d4cd5284afa893cd72664f9ff31a21d971dbe3d11328d84f0d54ad +size 14034 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/fa3b02a006469db9e191869e9a715d6e_img.jpg b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/fa3b02a006469db9e191869e9a715d6e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b6285b57befebb94dd98e8ea4e20e59ab6e3ffda --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/fa3b02a006469db9e191869e9a715d6e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:325ca7c57ec015c837690c2cd1a1e2f36222b9f74d0486cf481adaa57f5b349c +size 57161 diff --git a/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/raw.md b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..ab317acdd7c335230924320221be2342639f021e --- /dev/null +++ b/marked/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00/raw.md @@ -0,0 +1,7141 @@ + + +![O-RAN ALLIANCE logo](4b5691e53321f28dc4b69aa5026f2c62_img.jpg) + +The logo for O-RAN Alliance, featuring a stylized 'O' with a rainbow gradient and the text 'O-RAN ALLIANCE' in blue. + +O-RAN ALLIANCE logo + +O-RAN.WG9.XTRP-TST.0-R004-v05.00 + +Technical Specification + +# **O-RAN Open Xhaul Transport Working Group 9** + +## **Xhaul Transport Testing** + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +| Author | Company | Chapters | +|-------------------------------|-----------------|---------------------------------------| +| Lujing Cai | AT&T | Packet, Sync | +| Philippe Chancelou | Orange | Packet | +| Luis Miguel Contreras Murillo | Telefonica | Packet | +| Po-Hsiang Huang | Chungwa Telecom | Packet | +| Satheesh Kumar S | Juniper | Synchronization | +| Sebastien Prieur | EXFO | WDM | +| Sayantan Pramanick | Keysight | Packet | +| Krzysztof Szarkowicz | Juniper | Packet | +| Reza Vaez-Ghaemi | VIAVI Solutions | Overall coordination, Synchronization | +| Jim Zou | Adva | Optical | +| Mingqing Zou | CMCC | WDM | + +# 1 Revision History + +| Date | Revision | Author | Description | +|------------|----------|------------------------------------------------|--------------------------------------------------------------------------------| +| 07/09/2021 | V01.00 | R Vaez-Ghaemi | Version 01.00 | +| 07/22/2022 | V02.00 | Satheesh Kumar, S, Jiang, J Zou, R Vaez-Ghaemi | Addition of Synchronization, latency and OAM Test Cases | +| 07/06/2023 | V03.00 | Satheesh Kumar, M Zuo | Addition of WDM OAM (7.1.6), and Synchronization Test cases (9.3) | +| 01/20/2024 | V04.00 | Satheesh Kumar | Addition of Sync Test Cases in section 9.4 (9.4.1-9.4.7) | +| 10/03/2024 | V05.00 | Satheesh Kumar, Jiang Sun | Added WDM test cases, updated Inclusive Terminology in synchronization section | + +# 2 Contents + +| | | | | +|----|-------|---------------------------------------------------------------------------------------------------------------|----| +| 1 | 2 | Contents | | +| 2 | 1 | Revision History..... | 3 | +| 3 | 3 | Scope..... | 8 | +| 4 | 4 | References..... | 9 | +| 5 | 5 | Definitions and abbreviations..... | 12 | +| 6 | 5.1 | Definitions..... | 12 | +| 7 | 5.2 | Abbreviations..... | 12 | +| 8 | 6 | Test approach and methodology..... | 14 | +| 9 | 6.1 | System under test..... | 14 | +| 10 | 6.2 | Testing Parameters..... | 15 | +| 11 | 6.3 | Testing Methodologies..... | 15 | +| 12 | 6.4 | General (solution/technology agnostic) test use cases..... | 16 | +| 13 | 6.4.1 | Equipment Testing..... | 16 | +| 14 | 6.4.2 | PHY layer test..... | 24 | +| 15 | 6.4.3 | Alarm and Monitoring Test Cases..... | 36 | +| 16 | 7 | WDM-based Fronthaul Transport Testing..... | 47 | +| 17 | 7.1 | Fronthaul Testing use cases..... | 47 | +| 18 | 7.1.1 | Transmit Power..... | 47 | +| 19 | 7.1.2 | Receive Sensitivity..... | 49 | +| 20 | 7.1.3 | Auto-tuning test..... | 50 | +| 21 | 7.1.4 | Crosstalk testing..... | 52 | +| 22 | 7.1.5 | Latency Test..... | 55 | +| 23 | 7.1.6 | OAM Test..... | 58 | +| 24 | 7.1.7 | Management Interface Test..... | 66 | +| 25 | 7.1.8 | Performance of a pair of MUX/DEMUXs..... | 68 | +| 26 | 7.1.9 | Protection function for WDM system..... | 70 | +| 27 | 8 | Packet-Switched Architectures and Solutions Testing..... | 72 | +| 28 | 8.1 | Generalized basic verification methods for Xhaul Transport packet switched Network..... | 72 | +| 29 | 8.1.1 | Forwarding Verification..... | 76 | +| 30 | 8.1.2 | Latency Measurement and Verification..... | 77 | +| 31 | 8.1.3 | RFC 2544 Benchmarking test for frame loss rate, latency, throughput..... | 77 | +| 32 | 8.2 | Service Level Test Cases..... | 78 | +| 33 | 8.2.1 | Baseline 7-2x eCPRI transport over Packetized Fronthaul..... | 79 | +| 34 | 8.2.2 | Constraints based 7-2x eCPRI transport over Packetized Fronthaul using Headend Path calculation..... | 80 | +| 35 | 8.2.3 | Constraints based 7-2x eCPRI transport over Packetized Fronthaul using Controller based Path calculation..... | 81 | +| 36 | 8.2.4 | L3VPN based Services Verification for Xhaul network..... | 83 | +| 37 | 8.3 | Network element testing..... | 85 | +| 38 | 8.3.1 | Frame Pre-emption Testing..... | 85 | +| 39 | 8.3.1 | Auto-negotiation..... | 88 | +| 40 | 8.4 | Additional Network testing..... | 89 | +| 41 | 8.4.1 | Latency TNE at 1, 10 and 20 km distance..... | 90 | +| 42 | 8.4.2 | VLAN Manipulation Tests..... | 92 | +| 43 | 8.4.3 | QoS testing..... | 93 | +| 44 | 8.4.4 | Jitter Testing..... | 95 | +| 45 | 8.4.5 | Test for frame fragmentation..... | 97 | + +| | | | | +|----|--------|---------------------------------------------------------------------------------------------------|-----| +| 1 | 8.4.6 | Test for encapsulations and protocols ..... | 99 | +| 2 | 8.4.7 | Addition of background traffic ..... | 101 | +| 3 | 8.4.8 | Support of native IPv6 connectivity ..... | 103 | +| 4 | 8.4.9 | Support of IPv6 connectivity in an IPv4 network (dual stack) ..... | 104 | +| 5 | 8.4.10 | Support of IPv4 connectivity in an IPv6 network (dual stack) ..... | 105 | +| 6 | 8.4.11 | Test for in-band / out-band management ..... | 106 | +| 7 | 8.4.12 | Transparency of eCPRI EtherType ..... | 107 | +| 8 | 8.4.13 | Recovery times ..... | 108 | +| 9 | 8.4.14 | Test of Buffer Sizing ..... | 109 | +| 10 | 8.5 | Fronthaul Services Redundancy and High Availability ..... | 110 | +| 11 | 8.5.1 | Multi-Home Active/Active Fronthaul Redundancy ..... | 110 | +| 12 | 8.5.2 | Multi-Home Single-Active Bundle Fronthaul Redundancy ..... | 111 | +| 13 | 8.5.3 | Multi-Home Single-Active Standalone Fronthaul Redundancy ..... | 112 | +| 14 | 8.5.4 | Multi-Home Single-Active Standalone, Fronthaul Redundancy, no BD on O-DU ..... | 113 | +| 15 | 8.5.5 | Transport network Redundancy ..... | 115 | +| 16 | 8.6 | Legacy Fronthaul and C-RAN Coexistence Verification ..... | 116 | +| 17 | 8.6.1 | Legacy CPRI with RoE Type 0 Coexistence with 7-2x eCPRI ..... | 116 | +| 18 | 8.6.2 | Legacy CPRI with RoE Type 1 Coexistence with 7-2x eCPRI ..... | 118 | +| 19 | 9 | Xhaul Synchronization Testing ..... | 120 | +| 20 | 9.1 | Synchronization test use cases, parameters and methodologies ..... | 120 | +| 21 | 9.1.1 | Network Time Synchronization-LLS-C1 (Option-A) configuration ..... | 121 | +| 22 | 9.1.2 | Network Time Synchronization-LLS-C1 (Option-B) configuration: Scenario-1 ..... | 123 | +| 23 | 9.1.3 | Network Time Synchronization-LLS-C1 (Option-B) configuration: Scenario-2 ..... | 125 | +| 24 | 9.1.4 | Network Time Synchronization-LLS-C1 (Option-C) configuration ..... | 128 | +| 25 | 9.1.5 | Network Time Synchronization-LLS-C2 (Option-A) configuration ..... | 131 | +| 26 | 9.1.6 | Network Time Synchronization-LLS-C2 (Option-B) configuration: Scenario-1 ..... | 133 | +| 27 | 9.1.7 | Network Time Synchronization-LLS-C2 (Option-B) configuration: Scenario-2 ..... | 136 | +| 28 | 9.1.8 | Network Time Synchronization-LLS-C2 (Option-B) configuration (Fail-over: Scenario-1) ..... | 138 | +| 29 | 9.1.9 | Network Time Synchronization-LLS-C2 (Option-B) configuration (Fail-over: Scenario-2) ..... | 142 | +| 30 | 9.1.10 | Network Time Synchronization-LLS-C2 (Option-B) configuration (Fail-over: Scenario-3) ..... | 145 | +| 31 | 9.1.11 | Network Time Synchronization-LLS-C2 (Option-B) configuration (Time Error with Background | | +| 32 | | Traffic) ..... | 148 | +| 33 | 9.1.12 | Network Time Synchronization-LLS-C2 (Option-B) configuration (SyncE network wander limit for | | +| 34 | | chain of EEC and eEEC clock) ..... | 152 | +| 35 | 9.1.13 | Network Time Synchronization-LLS-C2 (Option-B) configuration (1PPS Time Error on O-RU) ..... | 153 | +| 36 | 9.1.14 | Network Time Synchronization-LLS-C3 (Option-A) configuration ..... | 155 | +| 37 | 9.1.15 | Network Time Synchronization-LLS-C3 (Option-B) configuration ..... | 158 | +| 38 | 9.1.16 | Network Time Synchronization-LLS-C3 (Option-B) configuration (Time Error with Background | | +| 39 | | Traffic) ..... | 160 | +| 40 | 9.1.17 | Network Time Synchronization-LLS-C3 (Option-B) configuration (PTP Holdover test) ..... | 164 | +| 41 | 9.1.18 | Network Time Synchronization-LLS-C3 (Option-B) configuration (PTP Fail-over/redundancy test) .... | 168 | +| 42 | 9.1.19 | Network Time Synchronization-LLS-C3 (Option-C) configuration ..... | 171 | +| 43 | 9.2 | Timing Solution & Resiliency in Ring Topology (LLS-C3) ..... | 174 | +| 44 | 9.2.1 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS- | | +| 45 | | C3)-Normal State (Case-1: T-GM1 is the preferred GM) ..... | 175 | +| 46 | 9.2.2 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS- | | +| 47 | | C3)-T-GM1 to BR1 Link Down. (Case-1: T-GM1 is the preferred GM) ..... | 178 | +| 48 | 9.2.3 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS- | | +| 49 | | C3)-T-GM1 Fail-over. (Case-1: T-GM1 is the preferred GM) ..... | 180 | + +| | | | | +|----|--------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----| +| 1 | 9.2.4 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Ring Fail-over in Backhaul. (Case-1: T-GM1 is the preferred GM)..... | 183 | +| 2 | | | | +| 3 | 9.2.5 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Ring Fail-over in Midhaul. (Case-1: T-GM1 is the preferred GM) ..... | 185 | +| 4 | | | | +| 5 | 9.2.6 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Ring Fail-over in Fronthaul. (Case-1: T-GM1 is the preferred GM) ..... | 188 | +| 6 | | | | +| 7 | 9.2.7 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Asymmetry Test (Case-1: T-GM1 is the preferred GM) ..... | 191 | +| 8 | | | | +| 9 | 9.2.8 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Asymmetry Test with Link-Fail. (Case-1: T-GM1 is the preferred GM) ..... | 193 | +| 10 | | | | +| 11 | 9.2.9 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Aggregated Link (Case-1: T-GM1 is the preferred GM)..... | 196 | +| 12 | | | | +| 13 | 9.2.10 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Aggregated Link-BR1 to BR3 primary member link down. (Case-1: T-GM1 is the preferred GM)..... | 198 | +| 14 | | | | +| 15 | | | | +| 16 | 9.2.11 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Normal State (Case-2: Both T-GMs are of equal preference)..... | 201 | +| 17 | | | | +| 18 | 9.2.12 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-T-GM1 to BR1 Link Down. (Case-2: Both T-GMs are of equal preference)..... | 203 | +| 19 | | | | +| 20 | 9.2.13 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Normal State (Case-3: T-GM1 is preferred through explicit configuration via Local-Priority on TNEs)..... | 206 | +| 21 | | | | +| 22 | | | | +| 23 | 9.2.14 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-T-GM1 to BR1 Link Down. (Case-3: T-GM1 is preferred through explicit configuration via Local-Priority on TNEs)..... | 209 | +| 24 | | | | +| 25 | | | | +| 26 | 9.2.15 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Normal State (Passive Port Monitoring)..... | 211 | +| 27 | | | | +| 28 | 9.2.16 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul (LLS-C3)-Normal State (Case-1: T-GM1 is the preferred GM) ..... | 214 | +| 29 | | | | +| 30 | 9.2.17 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul (LLS-C3)-T-GM1 to HSR1 Link Down. (Case-1: T-GM1 is the preferred GM) ..... | 217 | +| 31 | | | | +| 32 | 9.2.18 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul (LLS-C3)-T-GM1 Fail-over. (Case-1: T-GM1 is the preferred GM)..... | 220 | +| 33 | | | | +| 34 | 9.2.19 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul (LLS-C3)-Link Failure in Fronthaul. (Case-1: T-GM1 is the preferred GM) ..... | 222 | +| 35 | | | | +| 36 | 9.2.20 | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul (LLS-C3)-Asymmetry Test. (Case-1: T-GM1 is the preferred GM)..... | 225 | +| 37 | | | | +| 38 | 9.3 | Timing Solution Additional use cases in LLS-C3 and LLS-C4 config ..... | 228 | +| 39 | 9.3.1 | Network Time Synchronization-LLS-C4 with PTP frequency backup from T-GM..... | 229 | +| 40 | 9.3.2 | Network Time Synchronization-LLS-C4 with PTP Time backup from T-GM ..... | 231 | +| 41 | 9.3.3 | Network Time Synchronization-LLS-C4 and LLS-C3 mixed configurations for co-located DUs and RUs..... | 233 | +| 42 | | | | +| 43 | 9.3.4 | Network Time Synchronization-LLS-C4 and LLS-C3 mixed configurations for co-located DUs and RUs-GNSS Failure at O-RU site..... | 235 | +| 44 | | | | +| 45 | 9.3.5 | Network Time Synchronization-LLS-C4 and LLS-C3 mixed configurations with backup from redundant T-GM for co-located DUs and RUs ..... | 237 | +| 46 | | | | +| 47 | 9.3.6 | Network Time Synchronization-LLS-C4 and LLS-C3 mixed configurations with backup from redundant T-GM for co-located DUs and RUs (GNSS Failure at O-RU site). ..... | 239 | +| 48 | | | | +| 49 | 9.3.7 | Network Time Synchronization-LLS-C4 and LLS-C3 mixed configurations with backup from redundant T-GM for co-located DUs and RUs (GNSS & T-GM-A Failure). ..... | 240 | +| 50 | | | | + +| | | | | +|----|--------|--------------------------------------------------------------------------------------------------|-----| +| 1 | 9.3.8 | Network Time Synchronization-LLS-C3 configurations with GNSS assisted CSR for co-located | | +| 2 | | DUs and RUs..... | 242 | +| 3 | 9.3.9 | Network Time Synchronization-LLS-C3 configurations with (GNSS+PRTC) assisted CSR for co- | | +| 4 | | located DUs and RUs ..... | 244 | +| 5 | 9.3.10 | Network Time Synchronization-LLS-C3 configurations with GNSS assisted CSR with backup from | | +| 6 | | redundant T-GM for co-located DUs and RUs ..... | 247 | +| 7 | 9.3.11 | Network Time Synchronization-LLS-C3 configurations with GNSS assisted CSR with backup from | | +| 8 | | redundant T-GM for co-located DUs and RUs (GNSS Failure at CSR site)..... | 249 | +| 9 | 9.3.12 | Network Time Synchronization-LLS-C3 configurations with GNSS assisted CSR with backup from | | +| 10 | | redundant T-GM for co-located DUs and RUs (GNSS Failure at CSR site and T-GM-A Failure) ..... | 251 | +| 11 | 9.4 | Timing Solution use cases in LLS-C3 configuration for Shared O-RU..... | 254 | +| 12 | 9.4.1 | Timing Solution for Shared O-RU using common transport..... | 255 | +| 13 | 9.4.2 | Timing Solution for Shared O-RU with separate transport. .... | 257 | +| 14 | 9.4.3 | Timing Solution Resiliency for Shared O-RU with separate transport (Link Failure on T-GM1)..... | 260 | +| 15 | 9.4.4 | Timing Solution for Shared O-RU with separate transport (Redundant T-GM and HSR)..... | 262 | +| 16 | 9.4.5 | Timing Solution Resiliency for Shared O-RU with separate transport (Link Failure on HSR1) ..... | 264 | +| 17 | 9.4.6 | Timing Solution for Shared O-RU with separate transport (Full Redundancy) ..... | 266 | +| 18 | 9.4.7 | Timing Solution Resiliency for Shared O-RU with separate transport (GM1A and HSR1A Failure)..... | 269 | +| 19 | | Annex A: ITU G.8262/G.8262.1 Clock specification test cases for TNEs ..... | 272 | +| 20 | A.1 | Pull-in/Hold-in/Pull-out Limits..... | 272 | +| 21 | A.2 | Wander Generation Limit for EEC/eEEEC Clock ..... | 273 | +| 22 | A.3 | Wander Tolerance/Transfer Test for EEC/eEEEC Clock ..... | 273 | +| 23 | A.4 | Frequency Holdover Limits for EEC/eEEEC Clock ..... | 275 | +| 24 | A.5 | Short-term phase-transients as per ITU-T G.8262/G.8262.1 ..... | 276 | +| 25 | | Annex B: ITU G.8273.2 Clock specification test cases for TNEs ..... | 277 | +| 26 | B.1 | Time Noise Generation Performance ..... | 277 | +| 27 | B.2 | Time Noise Tolerance Performance Test ..... | 278 | +| 28 | B.3 | Time Holdover Performance Test ..... | 279 | +| 29 | | | | +| 30 | | | | + +1 + +2 + +# --- 3 Scope + +3 + +4 + +5 + +6 + +7 + +8 + +9 + +10 + +11 + +12 + +13 + +14 + +15 + +16 + +17 + +18 + +19 + +20 + +21 + +22 + +This document defines the testing requirements for an Open Xhaul transport infrastructure. It is based on Xhaul Transport Requirement document, Packet Switched Architectures and Solutions document, the WDM-based Fronthaul Transport, and Synchronization Architecture and Solution documents. It defines test cases and provides dedicated chapters for different solutions. + +This document uses information published by O-RAN, 3GPP, IEEE, ITU-T, IETF, CableLabs, NGMN and several other relevant standard bodies and industry associations. It contains educational, informative, and normative content. + +Version 02.00 of this document adds new test cases for synchronization (9.2) and WDM (7.1.5 & 7.1.6). +Version 3.0 adds new test cases for Synchronization (9.3) and WDM (7.1.6). + +What is not covered in this document: + +- The document shall minimize any unnecessary overlap with content presented in other O-RAN testing specifications such as WG4 Conformance Test (S-Plane) specification. Whereas the latter is about testing an O-RU or O-DU, this document verifies the transport networks placed between those O-RAN components. Some of the presented synchronization test cases may be moved from this document to other documents such as the WG4 Conformance Test specification in agreement with respective authors of the latter document. + +# 4 References + +The following documents contain provisions which, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. +- For a specific reference, subsequent revisions do not apply. +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document in Release 15. + +- | | | +|------|----------------------------------------------------------------------------------------------------------------------| +| [1] | 3GPP TS 38.472 V15.5.0: " F1 signalling transport (Release 15)". | +| [2] | IEEE 802.1Q-2018: "IEEE Standard for Local and metropolitan area networks— Bridges and Bridged Networks" | +| [3] | IETF RFC 2474: "Definition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 Headers" | +| [4] | IETF RFC 2598: "An Expedited Forwarding PHB" | +| [5] | IETF RFC 2597: "Assured Forwarding PHB Group" | +| [6] | IETF RFC 4594: "Configuration Guidelines for DiffServ Service Classes" | +| [7] | IETF RFC 826: "An Ethernet Address Resolution Protocol -- or -- Converting Network Protocol Addresses" | +| [8] | IETF RFC 792: "INTERNET CONTROL MESSAGE PROTOCOL" | +| [9] | IETF RFC 8200: "Internet Protocol, Version 6 (IPv6) Specification" | +| [10] | IETF RFC 4861: "Neighbor Discovery for IP version 6 (IPv6)" | +| [11] | IETF RFC 4443: "Internet Control Message Protocol (ICMPv6) for the Internet Protocol Version 6 (IPv6) Specification" | +| [12] | IETF RFC 6890: "Special-Purpose IP Address Registries" | +| [13] | IETF RFC 8190: "Updates to the Special-Purpose IP Address Registries" | +| [14] | IETF RFC 2131: "Dynamic Host Configuration Protocol" | +| [15] | IETF RFC 4361: "Node-specific Client Identifiers for Dynamic Host Configuration Protocol Version Four (DHCPv4)" | +| [16] | IETF RFC3315: "Dynamic Host Configuration Protocol for IPv6 (DHCPv6)" | +| [17] | IETF RFC4862: "IPv6 Stateless Address Autoconfiguration" | +| [18] | IETF RFC768: "User Datagram Protocol" | +| [19] | 3GPP TS 29.060 V15.0.0: "GPRS Tunnelling Protocol (GTP) across the Gn and Gp interface (Release 15)" | +| [20] | 3GPP TS 29.274 V16.1.0: "GPRS Tunnelling Protocol (GTP) across the Gn and Gp interface (Release 15)" | +| [21] | 3GPP TS 36.422 version 15.1.0: "X2 signalling transport (Release 15)" | +| [22] | 3GPP TS 36.424 version 15.0.0: "X2 data transport (Release 15)" | +| [23] | 3GPP TS 38.474 V15.3.0: " F1 data transport (Release 15)". | +| [24] | 3GPP TS 33.117 V16.2.0: "Catalogue of general security assurance requirements (Release 16)" | +| [25] | IETF RFC 2119: "Key words for use in RFCs to Indicate Requirement Levels" | +| [26] | IEEE 802.3-2018: "IEEE Standard for Ethernet" | +| [27] | IETF RFC 791: "INTERNET PROTOCOL" | +| [28] | IETF RFC 1918: "Address Allocation for Private Internets" | +| [29] | IETF RFC 5357: "A Two-Way Active Measurement Protocol (TWAMP)" | +| [30] | IETF RFC 4656: "A One-way Active Measurement Protocol (OWAMP)" | + +- [31] ITU-T G.8013/Y.1731(08/2015): "Operation, administration and maintenance (OAM) functions and mechanisms for Ethernet-based networks" +- [32] IETF RFC 4960. "Stream Control Transmission Protocol" +- [33] 3GPP TS 29.281 V15.6.0: "General Packet Radio System (GPRS) Tunneling Protocol User Plane (GTPv1-U) (Release 15)" +- [34] IETF RFC 1034: "DOMAIN NAMES - CONCEPTS AND FACILITIES" +- [35] IETF RFC 1035: "DOMAIN NAMES - IMPLEMENTATION AND SPECIFICATION" +- [36] IETF RFC 4210: "Internet X.509 Public Key Infrastructure Certificate Management Protocol (CMP)" +- [37] IETF RFC 6083: "Datagram Transport Layer Security (DTLS) for Stream Control Transmission Protocol (SCTP)" +- [38] 3GPP TS 33.501 V15.6.0: "Security architecture and procedures for 5G system (Release 15)" +- [39] IETF RFC 4301: "Security Architecture for the Internet Protocol" +- [40] 3GPP TS 33.210 V16.2.0: "Network Domain Security (NDS); IP network layer security (Release 16)" +- [41] 3GPP TS 33.310 V16.2.0: "Network Domain Security (NDS); Authentication Framework (AF) (Release 16)" +- [42] 3GPP TS 33.401 V16.0.0: "3GPP System Architecture Evolution (SAE); Security architecture (Release 15)" +- [43] 3GPP TR 33.821 V9.0.0: "Rationale and track of security decisions in Long Term Evolved (LTE) RAN / 3GPP System Architecture Evolution (SAE) (Release 9)" +- [44] IETF RFC 4303: "IP Encapsulating Security Payload (ESP)" +- [45] IETF RFC 8221: "Cryptographic Algorithm Implementation Requirements and Usage Guidance for Encapsulating Security Payload (ESP) and Authentication Header (AH)" +- [46] IETF RFC 7296: "Internet Key Exchange Protocol Version 2 (IKEv2)" +- [47] ETSI GS NFV-INF 005 V1.1.1 (2014-12): Network Functions Virtualisation (NFV); Infrastructure; Network Domain +- [48] 3GPP TS 38.462 V15.5.0: "E1 signalling transport (Release 15)" +- [49] MEF 22.3: "Transport Services for Mobile Networks, January 2018" +- [50] 3GPP TS 29.303 V16.0.0: "Domain Name System Procedures; Stage 3 (Release 16)" +- [51] eCPRI Transport Requirements V1.2, Common Public Radio Interface: Requirements for the eCPRI Transport Network, June 25, 2018. +- [52] IEEE 802.1CMde: Time-Sensitive Networking for Fronthaul Amendment: Enhancements to Fronthaul Profiles to Synchronization, and Synchronization Standards Networking for Fronthaul, —Support New Fronthaul Interface, July 26, 2019 +- [53] IEEE 1914.1™ D3.0, Draft Fronthaul Transport Networks, November 2018. +- [54] 3GPP TS 38.422 version 15.0.0 Release 15: Xn general aspects and principles +- [55] GSMA:"5G Implementation Guidelines: NSA Options" +- [56] NGMN: "NGMN Overview on 5G functional decomposition" +- [57] ITU-T GSTR-TN5G: "Transport Network support of IMT-2020-TG" +- [58] 3GPP 38.401: "NG-RAN; Architectural description" +- [59] O-RAN: "WG-4 Inter-Operability Testing" +- [60] O-RAN Open F1/W1/E1/X2/Xn Interfaces Working Group "Transport Specification" +- [61] O-RAN: "WDM-based Fronthaul Transport" +- [62] O-RAN: "Management interfaces for Transport Network Elements" +- [63] NGMN "5G RAN CU-DU network architecture, transport options and dimensioning, version 1.0 12 April 2019)" +- [64] 5G Transport Slice Connectivity Interface – draft-rokui-5g-transport-slice-00 +- [65] 3GPP R3-162102 TSG-RAN Working Group 3 Meeting #93-bis CU-DU split: Refinement for Annex A (Transport network and RAN internal functional split) + +- [66] 3GPP TS 38.101: “NR, User Equipment (UE) radio transmission and reception” +- [67] 3GPP TS 38.300: “NR Overall description” +- [68] GSMA: “5G Implementation Guidelines v2” +- [69] 3GPP TS 23.501 v6.4.0(2020-03): “System Architecture for 5G” +- [70] MEF 61.1: “IP Service attributes” +- [71] MEF 10.3: “Ethernet Service attributes” +- [72] MEF 6.2: “EVC service definition” +- [73] 3GPP TS38.306: “NR; User equipment (UE) radio access capabilities” +- [74] NGMN “Guidelines for LTE Backhaul estimations” +- [75] ITU-R M.2083: “IMT Vision – framework and overall objectives of the future development of IMT for 2020 and beyond”. +- [76] O-RAN Fronthaul Working Group, “Control, User and Synchronization Plane Specification”, v08.00 (04/2022) +- [77] 3GPP TS36.104, version 16.4.0, 01/2020, “Evolved Universal Terrestrial Radio Access (E-UTRA) Base Station (BS) and radio transmission and reception”. +- [78] 3GPP TS38.104, version 16.2.0, 01/2020, “NR Base Station (BS) and radio transmission and reception”. +- [79] ITU-T G.8271.1, 03/2020, “Network limits for time synchronization in packet networks with full timing support from the network” +- [80] ITU-T G.8272 Amendment 1, 03/2020, “Timing characteristics of primary reference time clocks” +- [81] ITU-T G.8272.1, Amendment 2, 08/2019, “Timing characteristics of enhanced primary reference time clocks” +- [82] ITU-T G.8275.1, 03/2020, “Precision time protocol telecom profile for phase/time synchronization with full timing support from the network “ +- [83] ITU-T G.8273.2 Amendment, 03/2020, “Timing characteristics of telecom boundary clocks and telecom timeReceiver clocks” +- [84] ITU-T G.8272/Y.1367, 11/2018. “Timing characteristics of primary reference time clocks” +- [85] 3GPP TS38.801, version 14.0.0, 03/2017, “Study on new radio access technology: Radio access architecture and interfaces” +- [86] NGMN “Overview on 5G RAN function decomposition”. +- [87] 3GPP TR22.804 v16.2.0 (2018-12), “Study on communications for automation in vertical domains” +- [88] ITU-T G.8271.1, 03/2020, “Network limits for time synchronization in packet networks with full timing support from the network”, Amendment 1, 10/2020. + +# 5 Definitions and abbreviations + +## 5.1 Definitions + +The key words "**SHALL**", "**SHALL NOT**", "**SHOULD**", "**SHOULD NOT**", "**MAY**", and "**OPTIONAL**" in this document are to be interpreted as described in IETF RFC 2119 [25]. All key words must be in upper case, bold text. + +Items that are **REQUIRED** (contain the words **SHALL** or **SHALL NOT**) will be labelled as **[Rx]** for required. Items that are **RECOMMENDED** (contain the words **SHOULD** or **SHOULD NOT**) will be labelled as **[Dx]** for desirable. Items that are **OPTIONAL** (contain the words **MAY** or **OPTIONAL**) will be labelled as **[Ox]** for optional. + +Items, if supported, are not meant to be active at all times, but should be available for use. Their state (active or not active) should be based on configuration. + +## 5.2 Abbreviations + +Abbreviations defined in this document take precedence over the definition of 3GPP. + +| | | | | +|----------------------|-----------------------------------------|---------------------------|-----------------------------------------------------------------| +| AF | Application Function | ITU-T | International Telecom Union-Telecom | +| AMF | Access and Mobility Management Function | LAN | Local Area Network | +| AN | Access Node | LLS | Lower Layer Split | +| ARP | Address Resolution Protocol | LTE | Long Term Evolution | +| ABW | Antenna Bandwidth | MAC | Medium Access Layer | +| BBU | Baseband Unit | MBSFN | Multimedia Broadcast multicast service Single Frequency Network | +| <a href="#">BER</a> | <a href="#">Bit Error Ratio</a> | <a href="#">MCU</a> | <a href="#">Microprogrammed Control Unit</a> | +| <a href="#">BERT</a> | <a href="#">Bit Error Rate Tester</a> | MPLS | Multi-Protocol Label Switching | +| BH | Backhaul | MIMO | Multiple Inputs Multiple Outputs | +| BiDi | Bidirectional | MNO | Mobile Network Operator | +| BTCA | Best TimeTransmitter Clock Algorithm | | | +| BS | Base Station | MRTD | Maximum Receive Time Difference | +| BW | Bandwidth | NGMN | Next Generation Mobile Network | +| CAPEX | Capital Expense | <a href="#">MUX/DEMUX</a> | <a href="#">Multiplexer/Demultiplexer</a> | +| CBS | Committed Burst Size | NR | New Radio | +| CFP | Common Form factor Pluggable | NSA | Non-Stand Alone | +| CIR | Committed Information Rate | NSSI | Subnet Networking Slices Instance | +| CN | Core Network | OAM | Operation Administration Maintenance | +| CoMP | Coordinated Multipoint | O-CU | O-RAN Central Unit | +| CP | Control Plane | O-DU | O-RAN Distributed Unit | +| CPRI | Common Public Radio Interface | OPEX | Operation Expense | +| CSR | Cell Site Router | O-RU | O-RAN Radio Unit | +| CU | Central Unit | PCF | Policy Control Function | +| DC | Data Center | PDCP | Packet Data Convergence Protocol | +| DL | Downlink | ppb | Parts per billion | +| DN | Data Network | PRB | Physical Resource Block | +| DHCP | Dynamic Host Configuration Protocol | PRTC | Primary Reference Telecom Clock | +| DSCP | Differentiated Services Codepoint | PTP | Precision Time Protocol | +| dTE <sub>H</sub> | Dynamic Time Error High | OFDM | Orthogonal Frequency Division Multiplexing | +| dTE <sub>L</sub> | Dynamic Time Error Low | QAM | Quadrature Amplitude Modulation | +| DU | Distributed Unit | QoS | Quality of Service | +| eCPRI | evolved Common Public Radio Interface | QSFP | Quad SFP | +| eMBB | enhanced Mobile Broadband | RB | Resource Block | +| eNB | Evolved NodeB | RRH | Remote Radio Head | + +| | | | | +|--------|------------------------------------------|-------|------------------------------------------------| +| EP | Ethernet Private | RU | Radio Unit | +| EPC | Evolved Packet Core | SCS | Sub Carrier Spacing | +| EPL | Ethernet Private Line | SCTP | Stream Control Transmission Protocol | +| ePRC | Enhanced Primary Reference Clock | SFF | Small Form Factor | +| ePRTC | Enhanced Primary Reference Telecom Clock | SFP | Small Form factor Pluggable | +| E-UTRA | evolved UMTS Terrestrial Radio Access | SLA | Service Level Agreement | +| EVP | Ethernet Virtual Private | SOH | Shared O-RU Host | +| EVPL | Ethernet Virtual Private Line | SRO | Shared Resource Operator | +| FDD | Frequency Division Duplex | TAE | Time Alignment Error | +| FFO | Fractional Frequency Offset | T-BC | Telecom Boundary Clock | +| FFS | For Further Study | TDD | Time Division Duplex | +| FH | Fronthaul | TE | Time Error (in the context of synchronization) | +| FLR | Frame Loss Ratio | T-GM | Telecom Grand Master | +| | | TT | TimeTransmitter | +| | | TR | TimeReceiver | +| FR1 | Frequency Range 1 | TN | Transport Node | +| FR2 | Frequency Range 2 | TNE | Transport Network Equipment | +| FTTH | Fiber To The Home | T-TSC | Telecom Time Synchronous Clock | +| gNB | gNodeB | TX | Transmit | +| GNSS | Global Navigation Satellite System | UDP | User Datagram Protocol | +| GPRS | General Packet Radio Service | UE | User equipment | +| GTP | GPRS Tunnelling Protocol | UL | Uplink | +| HSR | Hub Site Router | UNI | Universal Network Interface | +| ICMP | Internet Control Message Protocol | UNI-C | UNI-Customer edge | +| IoT | Internet of Things | UPF | User Plane Function | +| IP | Internet Protocol | URLLC | Ultra-Reliable Low Latency Communication | +| IQ | In phase Quadrature | VPN | Virtual Private Network | +| | | WDM | Wavelength Division Multiplexing | + +1 +2 +3 + +# 6 Test approach and methodology + +This section provides a definition of test use cases in Open Xhaul transport networks. + +## 6.1 System under test + +This specification covers cases that test: + +1. Xhaul networks from a UNI interface to another UNI interface +2. Xhaul network segments that carry traffic for an overlay network. +3. Individual TNEs or their components + +![Figure 6-1: Xhaul Transport Networks. This diagram illustrates the architecture of Xhaul transport networks, showing the flow of traffic from various radio units through transport network elements (TNEs) to the core network. The diagram is divided into two main sections: 'Outside of scope of WG9' (top) and 'Scope of WG9' (bottom). The top section shows a multi-tenant architecture where multiple O-RUs (Radio Units) connect to a central TNE. This TNE then connects to a series of TNEs representing the Fronthaul (eCPRI 7.2x), Midhaul (F1), and Backhaul (N2,N3) segments, eventually leading to a 5G Core network. The bottom section shows a more traditional architecture where RRHs (Remote Radio Heads) connect to TNEs, which then connect to a BBU (Baseband Unit) and finally to the EPC (Evolved Packet Core) via the S1 interface. A green dashed box highlights the 'Scope of WG9', which includes the Fronthaul, Midhaul, and Backhaul segments between UNI (User Network Interface) points. A note at the bottom states: 'Lines in this diagram represent logical connections. Actual physical connections may be different.'](5851c3b838048bc0accb6b7881aabef7_img.jpg) + +Figure 6-1: Xhaul Transport Networks. This diagram illustrates the architecture of Xhaul transport networks, showing the flow of traffic from various radio units through transport network elements (TNEs) to the core network. The diagram is divided into two main sections: 'Outside of scope of WG9' (top) and 'Scope of WG9' (bottom). The top section shows a multi-tenant architecture where multiple O-RUs (Radio Units) connect to a central TNE. This TNE then connects to a series of TNEs representing the Fronthaul (eCPRI 7.2x), Midhaul (F1), and Backhaul (N2,N3) segments, eventually leading to a 5G Core network. The bottom section shows a more traditional architecture where RRHs (Remote Radio Heads) connect to TNEs, which then connect to a BBU (Baseband Unit) and finally to the EPC (Evolved Packet Core) via the S1 interface. A green dashed box highlights the 'Scope of WG9', which includes the Fronthaul, Midhaul, and Backhaul segments between UNI (User Network Interface) points. A note at the bottom states: 'Lines in this diagram represent logical connections. Actual physical connections may be different.' + +**Figure 6-1: Xhaul Transport Networks** + +Figure 6-1 depicts a simplified overview of Xhaul transport networks that are composed of Fronthaul, Midhaul and Backhaul. The first category of test cases covers the network segments between UNI interfaces of Fronthaul, Midhaul or Backhaul. These test cases do not cross the O-DU or O-CU, and remain within the same network (Fronthaul, Midhaul, or Backhaul). + +Beyond these UNI interfaces, there may be other UNI interfaces within the individual Xhaul networks. Figure 6-2 illustrates one use case that includes UNI interfaces within a Fronthaul Network. An example is the use of a WDM physical interface (layer below) between packet-based solutions (layer above). Other use cases include -but are not limited to- use of wireless, PON, or DOCSIS infrastructure in Backhaul, Midhaul, or Fronthaul if the underlying technologies meet the necessary SLAs. + +![Diagram of UNI interfaces within Xhaul Networks. It shows a network topology where O-RU and O-DU are connected to TNE blocks, which are then connected to a central TNE block via UNI interfaces.](f6ac527e0b1bed3f41e5989ba3e86a07_img.jpg) + +**Fronthaul** + +``` + +graph LR + ORU[O-RU] --- TNE1[TNE] + TNE1 --- UNI1[UNI] + TNE1 --- TNE2[TNE] + TNE2 --- UNI2[UNI] + TNE2 --- TNE3[TNE] + TNE3 --- ODU[O-DU] + +``` + +Diagram of UNI interfaces within Xhaul Networks. It shows a network topology where O-RU and O-DU are connected to TNE blocks, which are then connected to a central TNE block via UNI interfaces. + +**Figure 6-2: UNI interfaces within Xhaul Networks** + +## 6.2 Testing Parameters + +The test cases in this specification relate to the metrics listed in existing WG9 requirement and solution documents. Examples include throughput, delay, time error or optical power level. + +## 6.3 Testing Methodologies + +Test methodologies can be categorized as follows: + +- Equipment level vs. network level test +- Technology specific test methodologies + +The equipment level tests verify the functionality or performance of an individual equipment or its components and are covered in the next section. The network level tests perform tests from a network UNI to another UNI across one or multiple equipment and are described in remaining chapters of this document. + +There are technology specification test cases. Optical layer tests perform tests at optical layer, they include power level or wavelength measurements. Packet layer tests use packet-based methods that generate and analyse Ethernet/eCPRI packets. Synchronization tests include measurements of time or frequency error that measure synchronizations signal or PTP timestamps against a reference signal that may be derived from a GNSS receiver. They may need to emulate a PTP timeTransmitter or timeReceiver function to be able to perform these measurements. + +## 6.4 General (solution/technology agnostic) test use cases + +### 6.4.1 Equipment Testing + +#### 6.4.1.1 TNE board extraction – insertion + +| | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Equipment.01 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | TNE board extraction – insertion | | | +| <b>Test Objective:</b> | The aim of the test is to check the system behavior in case of line board is physically removed from the TME shelf | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNE (Terrestrial Network Equipment) blocks connected via an XHAUL LINK. Each TNE contains Board 1 and Board 2. The left TNE is connected to CU, DU, and RU. The right TNE is connected to NGC/EPC, CU, and DU. A Traffic generator/Analyser is connected to both TNEs via 1/10/25/100 GbE links. The diagram also shows internal connections between Board 1 and Board 2 within each TNE." data-bbox="422 795 1173 1265" src="862365b7aea340b13f9b928757c8ffb8_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. TNE is connected to another TNE or O-RU/DU/CU & NGC/EPC, all services are running as defined in Traffic and services configuration.</li> <li>2. Make a line board extraction.</li> <li>3. Wait 2 minutes.</li> <li>4. Make a line board insertion.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that traffic and services emulation is running correctly after operation.</li> <li>2. Check services recovery time after line board extraction and insertion.</li> <li>3. Check generation and clearance of proper alarms.</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | All services MUST recover after extraction and insertion of line board | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | First service recovery time in seconds:<br>Last service recovery time in seconds: | | | + +###### 1 6.4.1.2 Fiber network disconnection-connection + +| | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Equipment.02 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Fiber network disconnection-connection | | | +| <b>Test Objective:</b> | The aim of the test is to check the system behavior after xhaul link connection/connection | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNE (Transport Network Element) blocks connected via an XHAUL LINK. Each TNE contains a stack of CU (Control Unit), DU (Data Unit), and RU (Radio Unit). Below the stack are Board 1 and Board 2. A yellow line connects Board 1 of the left TNE to Board 1 of the right TNE. A green line connects Board 2 of the left TNE to Board 2 of the right TNE. A Traffic generator/Analyser is connected to both Board 1 and Board 2 of both TNEs. Labels include '1 / 10 / 25 / 100 GbE' and 'NGC/EPC'." data-bbox="422 604 1165 1075" src="9e5b68d600d5777a5312a476134ed3da_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Make a network link disconnection/connection.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that traffic is running correctly after operation.</li> <li>2. Check services recovery time after the network link disconnection/connection.</li> <li>3. Check generation and clearance of proper alarms</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1- All services MUST recover after network link disconnection/connection</li> <li>2- There is no impact for other links</li> </ol> | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | First service recovery time in seconds:<br>Last service recovery time in seconds: | | | + +###### 1 6.4.1.3 Transceivers (SFP, QSFP, ...) extraction – insertion + +| | | | | +|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Equipment.03 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Transceivers (SFP, QSFP,...) extraction – insertion | | | +| <b>Test Objective:</b> | The aim of the test is to check if transceivers can be easily extracted/inserted | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A network diagram showing two TNE (Transport Network Elements) connected via an XHAUL LINK. Each TNE contains a stack of CU (Control Unit), DU (Data Unit), and RU (Radio Unit). Below the stack are two boards, Board 1 and Board 2. A yellow line connects Board 1 of the left TNE to Board 1 of the right TNE. A green line connects Board 2 of the left TNE to Board 2 of the right TNE. A Traffic generator/Analyser is connected to both Board 1 and Board 2 of both TNEs. Labels '1 / 10 / 25 / 100 GbE' are present near the boards and the traffic generator." data-bbox="422 571 1173 1041" src="43ac9db4eb883317998aa91613d7aa61_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Check if network side SFPs are easy-going to extracted/inserted.</li> <li>2. Make tests for all SFPs types used with devices.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that traffic is running correctly after operation.</li> <li>2. Check if the fibres are not impacted by cabinet door close</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1- Transceivers MUST be easy extracted and inserted</li> <li>2- The closed door of the shelf/cabinet MUST NOT impact fibres by too much bending or other ways</li> </ol> | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | | | | + +##### 1 6.4.1.4 TNE board swap + +| Test ID | Equipment.04 | Classification | Functionality | +|---------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | TNE board swap | | | +| Test Objective: | The aim of the test is to check TME behavior when Board is swapped | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <img alt="Test Topology Diagram: A network diagram showing two TNE (Terrestrial Network Element) blocks connected via an XHAUL LINK. Each TNE block contains Board 1 and Board 2. To the left of the first TNE is a stack of CU, DU, and RU. To the right of the second TNE is a stack of NGC/EPC, CU, and DU. A Traffic generator/Analyser is connected to both TNEs via green lines labeled '1 / 10 / 25 / 100 GbE'. A yellow line connects Board 1 of the first TNE to Board 1 of the second TNE." data-bbox="422 571 1173 1041" src="43ac9db4eb883317998aa91613d7aa61_img.jpg"/> | | | +| Procedure: | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. TNE is connected to another TNE or O-RU/DU/CU & NGC/EPC, start traffic over the services as defined in Traffic and services configuration</li> <li>2. Disconnect customers fiber and extract the TNE board</li> <li>3. Insert new TNE board in the same slot and connect the fiber to new TNE board (ex. Board 10GETh to 25GETh, 10GETh w/o sync. features to 10GETh with sync. feature...)</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Check services impact and alarms</li> </ol> | | | +| Test Configuration | Xhaul traffic and RAN services configuration | | | +| Pass/Fail Criteria: | <ol style="list-style-type: none"> <li>1. The services MUST recover on the new line board on step 3</li> <li>2. 2-LT board is operational without alarm</li> </ol> | | | +| Results | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| Test Output | | | | +| Comment | <p>Swap could be done between</p> <ul style="list-style-type: none"> <li>- two identical boards (same type and hardware version)</li> <li>- two boards with same type but with different hardware version</li> <li>- two boards with different type and hardware version (for example 1GETh board replaced by 10GETh board)</li> </ul> | | | + +#### 6.4.1.5 Restarts – TNE electric power off-on + +| | | | | +|---------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test ID | Equipment.05 | Classification | Functionality | +| Test Title | Restarts – TNE electric power off-on | | | +| Test Objective: | The aim of the test is to check if the system behavior after electrical power off/on | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <img alt="Test Topology Diagram: Two TNE blocks are connected via an XHAUL LINK. Each TNE contains Board 1 and Board 2. A Traffic generator/Analyser is connected to both TNEs via 1/10/25/100 GbE links. The diagram also shows connections to CU/NGC/EPC and DU blocks." data-bbox="414 571 1165 1041" src="7a979cd806a799070d18d98391c0fe12_img.jpg"/> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect TNE to another TNE or O-RU/DU/CU & NGC/EPC, start traffic over the services as defined in Traffic and services configuration chapter</li> <li>2. Save the configuration</li> <li>3. Make an TNE electrical off/on</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Check the relevant table (MAC, vMAC, DHCP, ARP) persistency/recovery.</li> <li>2. Verify that traffic is running correctly after operation.</li> <li>3. Check services recovery time after operation.</li> <li>4. Note time recover</li> </ol> | | | +| Test Configuration | Xhaul traffic and RAN services configuration | | | +| Pass/Fail Criteria: | All services MUST recover after electrical TNE power off/on | | | +| Results | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| Test Output | First service recovery time in seconds:<br>Last service recovery time in seconds: | | | + +##### 1 Restarts – TNE board software reset + +| | | | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Equipment.06 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Restarts – TNE board software reset | | | +| <b>Test Objective:</b> | The aim of the test is to check if the system behavior after board software reset | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: Two TNE blocks are connected via an XHAUL LINK. Each TNE block contains Board 1 and Board 2. To the left of the first TNE is a stack of CU, DU, and RU. To the right of the second TNE is a stack of NGC/EPC, CU, and DU. A Traffic generator/Analyser is connected to both TNE blocks via green lines labeled '1 / 10 / 25 / 100 GbE'. Blue lines connect Board 1 and Board 2 within each TNE." data-bbox="414 560 1165 1030" src="8670a4ef771d8f3c3a7082cece1c3fb4_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect TNE to another TNE or O-RU/DU/CU & NGC/EPC, start traffic over the services as defined in Traffic and services configuration chapter</li> <li>2. Save the configuration</li> <li>3. Make an TNE board software reset</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Check the relevant table (MAC, vMAC, DHCP, ARP) persistency/recovery.</li> <li>2. Verify that traffic is running correctly after operation.</li> <li>3. Check services recovery time after operation.</li> <li>4. Note time recover</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | All services MUST recover after TNE board software reset | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | First service recovery time in seconds:<br>Last service recovery time in seconds: | | | + +##### 1 6.4.1.6 Mirror port + +| | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Equipment.07 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Mirror port | | | +| <b>Test Objective:</b> | The aim of the test is to check if TNE supports port monitoring | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNE (TNE1 and TNE2) connected via an XHAUL LINK. Each TNE contains a stack of CU, DU, and RU. Below the stack are Board 1 and Board 2. A Traffic generator/Analyser is connected to both Board 1 and Board 2 of both TNEs. Green lines represent traffic paths between the boards and the Traffic generator/Analyser, labeled with '1 / 10 / 25 / 100 GbE'." data-bbox="422 571 1173 1041" src="43ac9db4eb883317998aa91613d7aa61_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Configure TNE port.</li> <li>2. Configure TNE mirror port to other port.</li> <li>3. Send bidirectional traffic through TNE.</li> <li>4. Capture traffic on mirror port</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that the traffic was captured on mirror port.</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | All traffic on source port MUST be visible on mirror port | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | | | | + +###### 1 6.4.1.7 Board provisioning + +| | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Equipment.08 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Board provisioning | | | +| <b>Test Objective:</b> | The aim of the test is to check no problem is observed when a new board is installed and configured in the TNE shelf | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNE (Tactical Network Element) shelves connected via an XHAUL LINK. Each TNE shelf contains Board 1 and Board 2. The left TNE is connected to CU, DU, and RU. The right TNE is connected to NGC/EPC, CU, and DU. A Traffic generator/Analyser is connected to both TNE shelves via 1/10/25/100 GbE links. The diagram also shows 1/10/25/100 GbE links between the boards and the Traffic generator/Analyser." data-bbox="422 604 1165 1075" src="9e5b68d600d5777a5312a476134ed3da_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Insert board in an empty slot.</li> <li>2. Make relevant action if necessary (Plan board, acknowledgment, etc.).</li> <li>3. List alarm(s) reported during operation.</li> <li>4. Connect and provision traffic.</li> <li>5. Send traffic.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Board is detected in step 1.</li> <li>2. Board is recognized in step 2.</li> <li>3. Connection is created in step 4.</li> <li>4. Traffic is running without error in step 5</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | | | | + +2 +3 +4 + +### 6.4.2 PHY layer test + +#### 6.4.2.1 Transceiver operating wavelength + +| Test ID | PHY.01 | Classification | Functionality | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Transceiver operating wavelength | | | +| Test Objective: | The aim of the test is to check the conformity of operating wavelength of the transceiver with adequate specification (IEEE, MSA, ITU,...) | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <img alt="Test Topology Diagram: A diagram showing two TNE (Transceiver Network Element) blocks connected via an XHAUL LINK. Each TNE contains Board 1 and Board 2. An Optical Splitter 1:2 is connected to the XHAUL LINK. An Optical Spectrum Analyzer is connected to the splitter. A Traffic generator/Analyser is connected to the TNEs. The link is labeled 1 / 10 / 25 / 100 GbE." data-bbox="422 761 1428 1310" src="90d97add5992a9d4038ffc88c115bbb1_img.jpg"/> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>1. Insert an optical spectrum analyser and 1 to 2 splitter as described on relevant test setup <ol style="list-style-type: none"> <li>a. For bidirectional link (half duplex)</li> <li>b. For full duplex link: insert splitter on the required transmission link and connect the other link directly.</li> </ol> </li> <li>2. Start traffic as defined in Ethernet tests case.</li> <li>3. Measure the wavelength of generated signal with optical spectrum analyzer.</li> <li>4. Check the wavelength value of the transceiver remotely based on digital diagnostic.</li> <li>5. Note the result.</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Traffic correctly forwarded on step 2 and step 3</li> <li>2. TNE operational without alarms on step 2 and step 3</li> <li>3. Wavelength of generated signal in accordance with the specification</li> </ol> | | | +| Test Configuration | Xhaul traffic and RAN services configuration | | | + +| <b>Pass/Fail Criteria:</b> | 1. Wavelength of generated signal MUST be in accordance with the specification.<br>2. Digital diagnostic wavelength value in accordance with measure value | | | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------|----------------|-----------------|--------------------------|----------------|--| +| <b>Results</b> | [ ] Pass   [ ] Pass w/X   [ ] Dropped   [ ] Blocked   [ ] Failed | | | | | | | +| <b>Test Output</b> | <b>Comments:</b><br>The results are presented in the table below:<br><br><table border="1"> <tr> <th>Transceiver</th> <th>Recommendation</th> <th>Measured values</th> </tr> <tr> <td> Vendor:<br/> Model:<br/> SN: </td> <td>xxxx +/- yy nm</td> <td></td> </tr> </table> | Transceiver | Recommendation | Measured values | Vendor:<br>Model:<br>SN: | xxxx +/- yy nm | | +| Transceiver | Recommendation | Measured values | | | | | | +| Vendor:<br>Model:<br>SN: | xxxx +/- yy nm | | | | | | | + +#### 6.4.2.2 Mean launched optical power of transceiver. + +| Test ID | PHY.02 | Classification | Functionality | +|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Mean launched optical power of transceiver | | | +| Test Objective: | The aim of the test is to check the conformity of mean launched optical power of the transceiver with adequate specification (IEEE, MSA, ITU,...) | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <img alt="Test Topology Diagram: A diagram showing two TNE (Transceiver Network Element) blocks connected via an XHAUL LINK. Each TNE contains Board 1 and Board 2. An Optical Splitter 1:2 is connected to the XHAUL LINK. A Power Meter is connected to the Optical Splitter. A Traffic generator/Analyser is connected to the TNE blocks. The diagram also shows CU, DU, and RU blocks connected to the TNE blocks. The Optical Splitter is labeled 1:2. The Traffic generator/Analyser is labeled 1 / 10 / 25 / 100 GbE. The Optical Splitter is labeled 1:2. The Power Meter is labeled 1 / 10 / 25 / 100 GbE." data-bbox="422 660 1412 1198" src="21eb1cdc2e7868206dd3b3125d0aaf36_img.jpg"/> | | | +| Procedure: | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Insert an optical power meter and 1 to 2 splitter as described on relevant test setup <ol style="list-style-type: none"> <li>a. For bidirectional link (half duplex)</li> <li>b. For full duplex link: insert splitter on the required transmission link and connect the other link directly.</li> </ol> </li> <li>2. Start traffic as defined in Ethernet tests case.</li> <li>3. Measure and report the optical power by power meter at the adequate wavelength displayed by power meter (1 measurement) [calibration is required including optical splitter loss]</li> <li>4. Check the received optical output power of the transceiver remotely based on digital diagnostic.</li> <li>5. Note the result.</li> <li>6. Measure and report the repeatability of the optical power by power meter and remotely by digital diagnostic after fiber disconnection / connection on the transceiver (3 additional measurements)</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Traffic correctly forwarded on step 2, 3 and 4</li> <li>2. TNE operational without alarms on step 2 and step 3</li> <li>3. Optical power of generated signal in accordance with the specification</li> </ol> | | | + +| <b>4.</b> Digital diagnostic received optical value in accordance with measure value | | | | | | | | | | | | | | +|--------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------|----------------|---------------------------------------------------------------------------------------------------|--|--|--|-----------------------|--------------|--|--|--|--| +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | | | | | | | | | | | +| <b>Pass/Fail Criteria:</b> | 1. All optical power measurements of generated signal <b>MUST</b> be in accordance with the specification.<br>2. Digital diagnostic transmitter optical output power <b>MUST</b> be in accordance with measured values | | | | | | | | | | | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | | | | | | | | | | | +| <b>Test Output</b> | <b>Comments:</b><br>The results are presented in the table below: <table border="1"> <tr> <th>Transceiver</th> <th>Recommendation</th> <th colspan="4">Measured values (after fibre disconnection / connection) by power meter and by digital diagnostic</th> </tr> <tr> <td>Vendor<br/>Model<br/>SN</td> <td>(xx, yy) dBm</td> <td></td> <td></td> <td></td> <td></td> </tr> </table> | Transceiver | Recommendation | Measured values (after fibre disconnection / connection) by power meter and by digital diagnostic | | | | Vendor<br>Model<br>SN | (xx, yy) dBm | | | | | +| Transceiver | Recommendation | Measured values (after fibre disconnection / connection) by power meter and by digital diagnostic | | | | | | | | | | | | +| Vendor<br>Model<br>SN | (xx, yy) dBm | | | | | | | | | | | | | + +1 + +#### 6.4.2.3 Optical sensitivity of transceiver + +2 + +| Test ID | PHY.03 | Classification | Functionality | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Optical sensitivity of transceiver | | | +| Test Objective: | The aim of the test is to check the conformity of optical sensitivity of the transceiver with adequate specification (IEEE, MSA, ITU,...) | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <p>Image: Test Topology Diagram: A diagram showing the optical sensitivity test setup. It features two TNE (Transceiver Network Element) blocks, each containing a CU (Control Unit), DU (Data Unit), and RU (Radio Unit). The TNEs are connected via an XHAUL LINK. An optical splitter is placed between the TNEs, with an optical attenuator in the path. Power meters are connected to the optical paths. The diagram also shows a Traffic generator/Analyser connected to the TNEs via 1/10/25/100 GbE links. The optical paths are labeled with X nm and Y nm wavelengths.</p> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>1. Insert an optical power meter with 1 to 2 splitter and a variable optical attenuator with optical multiplexor (or circulator) at adequate wavelength and link as described on relevant test setup. <ol style="list-style-type: none"> <li>a. For bidirectional link (half duplex) : top part of the set up</li> <li>b. For full duplex link: bottom part of the set up.</li> </ol> </li> <li>2. Configure if possible FEC off or FEC on or type of FEC on</li> <li>3. Start traffic as defined in Ethernet tests case.</li> <li>4. Increase the optical attenuation gradually on attenuator [dB] till the moment when dropping of Ethernet frames / bit errors are observed.</li> <li>5. Measure and report the optical power at the adequate wavelength displayed by optical power meter [calibration is required including optical splitter loss]</li> <li>6. Check the received optical power of the transceiver remotely based on digital diagnostic.</li> <li>7. Note the result.</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Traffic correctly forwarded on step 3 and 4 (before drop frame)</li> <li>2. TNE operational without alarms on step 3 and 4 (before drop frame)</li> <li>3. Optical sensitivity of transceiver in accordance with the specification</li> <li>4. Digital diagnostic received optical value in accordance with measure value</li> </ol> | | | + +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | | | | | | | +|--------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------|--|-------------|----------------|--------------------------------|--------------------------------------------|--------|--| +| <b>Pass/Fail Criteria:</b> | 1. Optical sensitivity of transceiver MUST be in accordance with the specification.<br>2. Digital diagnostic received optical value MUST be in accordance with measured value | | | | | | | | | +| <b>Results</b> | [ ] Pass   [ ] Pass w/X   [ ] Dropped   [ ] Blocked   [ ] Failed | | | | | | | | | +| <b>Test Output</b> | <p><b>Comments:</b><br/> The results are presented in the table below:<br/> Forward Error Correction (FEC): state/type</p> <table border="1"> <thead> <tr> <th>Transceiver</th> <th>Recommendation</th> <th>Measured values<br/>(FEC state)</th> </tr> </thead> <tbody> <tr> <td><b>Vendor</b><br/><b>Model</b><br/><b>SN</b></td> <td>xx dBm</td> <td></td> </tr> </tbody> </table> | | | Transceiver | Recommendation | Measured values<br>(FEC state) | <b>Vendor</b><br><b>Model</b><br><b>SN</b> | xx dBm | | +| Transceiver | Recommendation | Measured values<br>(FEC state) | | | | | | | | +| <b>Vendor</b><br><b>Model</b><br><b>SN</b> | xx dBm | | | | | | | | | + +1 + +##### 1 6.4.2.4 Minimum optical overload of transceiver + +2 + +| Test ID | PHY.04 | Classification | Functionality | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Minimum optical overload of transceiver | | | +| Test Objective: | The aim of the test is to check the conformity of minimum optical overload of the transceiver with adequate specification (IEEE, MSA, ITU,...) | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <p>Image: Test Topology Diagram: A diagram showing the test setup for minimum optical overload of a transceiver. It features two TNE (Transceiver Network Element) blocks, each containing a CU (Control Unit), DU (Distributed Unit), and RU (Radio Unit). The TNEs are connected via an XHAUL LINK. The left TNE has two boards (Board 1 and Board 2) connected to an optical splitter. The right TNE also has two boards connected to an optical attenuator. The optical splitter and attenuator are connected via an optical multiplexor (or circulator). Power meters are placed at the input and output of the optical multiplexor. Traffic is generated by a Traffic generator/Analyser, which is connected to the RU of both TNEs. The traffic flows through the DU and CU of each TNE, then through the boards, and finally through the optical components. The diagram also shows various optical power levels (X nm, Y nm) and data rates (1 / 10 / 25 / 100 GbE) at different points in the setup.</p> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>1. Insert an optical power meter with 1 to 2 splitter and a variable optical attenuator with optical multiplexor (or circulator) at adequate wavelength and link as described on relevant test setup. <ol style="list-style-type: none"> <li>a. For bidirectional link (half duplex): top part of the set up.</li> <li>b. For full duplex link: bottom part of the set up.</li> </ol> </li> <li>2. Start traffic as defined in Ethernet tests case.</li> <li>3. Decrease the optical attenuation gradually on attenuator [dB] till the moment when dropping of Ethernet frames / bit errors are observed.</li> <li>4. Measure and report the optical power at the adequate wavelength displayed by optical power meter [calibration is required including optical splitter loss]</li> <li>5. Check the received optical power of the transceiver remotely based on digital diagnostic.</li> <li>6. Note the result.</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Traffic correctly forwarded on step 2 and 3 (before drop frame)</li> <li>2. TNE operational without alarms on step 2 and 3 (before drop frame)</li> <li>3. Minimum optical overload of transceiver in accordance with the specification</li> <li>4. Digital diagnostic received optical value in accordance with measure value</li> </ol> | | | +| Test Configuration | Xhaul traffic and RAN services configuration | | | + +| <b>Pass/Fail Criteria:</b> | 1. Minimum optical overload of transceiver MUST be in accordance with the specification.<br>2. Digital diagnostic received optical value MUST be in accordance with measured value | | | | | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|--------------------------|----------------|--------------------------|-----------------------|--------|--|--| +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | | | | | | | +| <b>Test Output</b> | <p><b>Comments:</b><br/> The results are presented in the table below:<br/> Forward Error Correction (FEC): state/type</p> <table border="1"> <tr> <th>Transceiver</th> <th>Recommendation</th> <th>Measured value</th> <th>Digital diagnostic value</th> </tr> <tr> <td>Vendor<br/>Model<br/>SN</td> <td>xx dBm</td> <td></td> <td></td> </tr> </table> | Transceiver | Recommendation | Measured value | Digital diagnostic value | Vendor<br>Model<br>SN | xx dBm | | | +| Transceiver | Recommendation | Measured value | Digital diagnostic value | | | | | | | +| Vendor<br>Model<br>SN | xx dBm | | | | | | | | | + +##### 1 6.4.2.5 Transceiver at minimum and maximum distance (km) + +2 + +| Test ID | PHY.05 | Classification | Functionality | +|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Transceiver at minimum and maximum distance (km) | | | +| Test Objective: | The aim of the test is to check the conformity to distance parameter with adequate specification (IEEE, MSA, ITU,...) | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <p>Image: Test Topology Diagram: A diagram showing the test setup. On the left, a stack of CU, DU, and RU is connected to a TNE (Test Network Element) containing Board 1 and Board 2. A Power Meter is connected to Board 1. On the right, another TNE with Board 1 and Board 2 is connected to an NGC/EPC stack (CU, DU). An Optical Splitter 1:2 is connected to Board 1 of the left TNE. One output of the splitter goes to an Optical attenuator, which is connected to Board 1 of the right TNE. The other output of the splitter goes to an Optical fiber loop labeled 'Optical fiber X km', which is also connected to Board 1 of the right TNE. A Traffic generator/Analyser is connected to Board 2 of both TNEs. Data rates of 1/10/25/100 GbE are indicated for the connections.</p> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>1. Insert an optical fiber loop of maximum km length, a variable optical attenuator, and an optical power meter connected to a 1 to 2 splitter as described on relevant test setup. <ol style="list-style-type: none"> <li>a. For bidirectional link (half duplex)</li> <li>b. For full duplex link: insert test devices on the required transmission link and connect the other link directly.</li> </ol> </li> <li>2. Configure if possible FEC off or FEC on or type of FEC on</li> <li>3. Set an attenuation of optical attenuator to the value relating to the optical sensitivity value.</li> <li>4. Start traffic as defined in Ethernet tests case.</li> <li>5. Fifteen minutes later, disconnect / connect the transceivers.</li> <li>6. Control the traffic.</li> <li>7. Insert minimum km of optical.</li> <li>8. Set an attenuation of optical attenuator to the value relating to the optical sensitivity value.</li> <li>9. Control the traffic.</li> <li>10. Fifteen minutes later, disconnect / connect the transceivers.</li> <li>11. Control the traffic.</li> </ol> | | | + +| | 12. Set an attenuation of optical attenuator to the value relating to the optical overload value.<br>13. Control the traffic.<br>14. Fifteen minutes later, disconnect / connect the transceivers.<br>15. Control the traffic.<br>16. Check the link length supported pf the transceiver remotely based on digital diagnostic.<br>17. Note the result.<br><b><u>Verifications needed:</u></b><br>1. Traffic correctly forwarded on step 4, 6, 9, 11, 13 and 15.<br>2. TNE operational without alarms on step 4, 6, 9, 11, 13 and 15.<br>3. Digital diagnostic link length supported in accordance with maximum km of fiber | | | | | | | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------|----------------|-----------------|--------|------------|--|-------|----|------------|--| +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | | | | | | | | | +| <b>Pass/Fail Criteria:</b> | 1. Traffic is correctly forwarded without frame loss on step 4, 6, 9, 11, 13 and 15.<br>2. Maximum km of fiber must be equal or greater than the specified value.<br>3. Minimum km of fiber must be equal or less than the specified value.<br>4. Digital diagnostic link length supported must be in accordance with maximum km of fiber. | | | | | | | | | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | | | | | | | | | +| <b>Test Output</b> | <b>Comments:</b><br>The results are presented in the table below:<br>Forward Error Correction (FEC): state/type <table border="1"> <thead> <tr> <th>Transceiver</th> <th>Recommendation</th> <th>Measured values</th> </tr> </thead> <tbody> <tr> <td>Vendor</td> <td rowspan="2">Minimum km</td> <td rowspan="2"></td> </tr> <tr> <td>Model</td> </tr> <tr> <td>SN</td> <td>Maximum km</td> <td></td> </tr> </tbody> </table> | Transceiver | Recommendation | Measured values | Vendor | Minimum km | | Model | SN | Maximum km | | +| Transceiver | Recommendation | Measured values | | | | | | | | | | +| Vendor | Minimum km | | | | | | | | | | | +| Model | | | | | | | | | | | | +| SN | Maximum km | | | | | | | | | | | + +#### 6.4.2.6 Transceiver extinction ratio and eye diagram + +This test case is FFS. + +| <b>Test ID</b> | PHY.06 | <b>Classification</b> | Functionality | | | | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------|-------------|----------------|-----------------|-----------------------|--|--| +| <b>Test Title</b> | Transceiver extinction ratio and eye diagram | | | | | | | | | +| <b>Test Objective:</b> | The aim of the test is to check the conformity | | | | | | | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | | | | | | | +| <b>Test Topology:</b> | | | | | | | | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <p>18. x</p> <p><b><u>Verifications needed:</u></b></p> <p>1. x</p> <p>2.</p> | | | | | | | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | | | | | | | +| <b>Pass/Fail Criteria:</b> | 5. x | | | | | | | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | | | | | | | +| <b>Test Output</b> | <p><b>Comments:</b><br/> The results are presented in the table below:</p> <table border="1"> <thead> <tr> <th>Transceiver</th><th>Recommendation</th><th>Measured values</th></tr> </thead> <tbody> <tr> <td>Vendor<br/>Model<br/>SN</td><td></td><td></td></tr> </tbody> </table> | | | Transceiver | Recommendation | Measured values | Vendor<br>Model<br>SN | | | +| Transceiver | Recommendation | Measured values | | | | | | | | +| Vendor<br>Model<br>SN | | | | | | | | | | + +#### 6.4.2.7 Transceiver information display + +| Test ID | PHY.07 | Classification | Functionality | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Transceiver information display | | | +| Test Objective: | The aim of the test is to check information of optical interface remotely | | | +| Pre-Req | | | | +| Test Topology: | | | | +| Procedure: | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure and Verification:</u></b></p> <ol style="list-style-type: none"> <li>1. Insert the transceiver.</li> <li>2. Check the type of optical transceiver remotely and all available digital diagnostic values.</li> <li>3. Note the result.</li> </ol> | | | +| Test Configuration | Xhaul traffic and RAN services configuration | | | +| Pass/Fail Criteria: | <p>The system MUST show:</p> <ul style="list-style-type: none"> <li>• Type/class</li> <li>• SFP vendor</li> <li>• Part number</li> <li>• S/N</li> <li>• Manufacturing date</li> <li>• Link length supported.</li> <li>• Temperature</li> <li>• Supply voltage</li> <li>• Tx bias current</li> <li>• Tx output power</li> <li>• Rx optical power</li> </ul> | | | +| Results | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| Test Output | <b>Comments:</b> | | | + +### 6.4.3 Alarm and Monitoring Test Cases + +#### 6.4.3.1 Alarm on board reset and plug out. + +| Test ID | Alarm & Monitoring.01 | Classification | Functionality | +|---------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Alarm on board reset and plug out | | | +| Test Objective: | The aim of the test is to check if TNE send and cleared alarm when board is rebooted or plugout/plugin | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <img alt="Test Topology Diagram: A diagram showing a Traffic generator/Analyser connected to a TNE (Target Network Element). The TNE contains Board 1 and Board 2. The Traffic generator/Analyser is connected to the TNE via two green lines labeled '1 / 10 / 25 / 100 GbE'. Board 1 and Board 2 are also connected to the TNE via green lines labeled '1 / 10 / 25 / 100 GbE'." data-bbox="424 757 778 1223" src="2e906baeab07d760989400bfd3215338_img.jpg"/> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure & Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Perform a board reset/reboot.</li> <li>2. Measure and report the duration to raise the alarm from the line/interface disconnection.</li> <li>3. After board recover</li> <li>4. Measure and report the duration to clear the alarm from the line/interface disconnection.</li> <li>5. Perform a board plug-out.</li> <li>6. Measure and report the duration to raise the alarm from the line/interface disconnection.</li> <li>7. Perform a board plugin.</li> <li>8. Measure and report the duration to clear the alarm from the line/interface disconnection</li> </ol> | | | +| Test Configuration | Xhaul traffic and RAN services configuration | | | +| Pass/Fail Criteria: | <ol style="list-style-type: none"> <li>1- Alarm reported within 1 minute on step 2 and 6</li> <li>2- Alarm cleared within 1 minute on step 4 and 8</li> </ol> | | | + +| | | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Results</b> | <input type="checkbox"/> Pass <input type="checkbox"/> Pass w/X <input type="checkbox"/> Dropped <input type="checkbox"/> Blocked <input type="checkbox"/> Failed | +| <b>Test Output</b> | Alarms is reported xx second.<br>Alarms is cleared xx second | + +###### 1 6.4.3.2 Alarm time stamping + +| Test ID | Alarm & Monitoring.02 | Classification | Functionality | +|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Alarm time stamping | | | +| Test Objective: | The aim of the test is to check if for TNE is possible to determine the exact time when the alarm was raised | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <img alt="Test Topology Diagram: A diagram showing a TNE (Test Network Element) represented by a blue trapezoid. Inside the TNE are two blue rectangles labeled 'Board 1' and 'Board 2'. Below the TNE is a grey rectangle labeled 'Traffic generator/Analyser'. Green lines connect the Traffic generator/Analyser to Board 1 and Board 2, with labels '1 / 10 / 25 / 100 GbE' on each line. Ellipses (...) are shown on the left and right sides of the TNE." data-bbox="427 607 778 1077" src="399ad7bd558d674e3ea1b07456a91e3c_img.jpg"/> | | | +| Procedure: | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Simulate few alarms.</li> <li>2. Show alarms history.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Check if time stamping (Date and Time) is available for all alarms and events/warnings.</li> <li>2. Check if is possible to retrieve the exact time when the alarm was raised from the alarm timestamp</li> </ol> | | | +| Test Configuration | Xhaul traffic and RAN services configuration | | | +| Pass/Fail Criteria: | <ol style="list-style-type: none"> <li>1- There MUST be possible to check time stamping on TNE</li> <li>2- There MUST be possible to determine the exact time when the alarm was raised</li> </ol> | | | +| Results | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| Test Output | | | | + +###### 1      6.4.3.3 Ethernet link down alarm + +2      This test is FFS. + +3 + +| | | | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Alarm & Monitoring.03 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Ethernet link down alarm | | | +| <b>Test Objective:</b> | The aim of the test is to generate and clear an Ethernet link down alarm xhaul link | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNE (Transport Network Element) blocks connected via an XHAUL LINK. Each TNE contains a stack of CU, DU, and RU. Below the stack are Board 1 and Board 2. A Traffic generator/Analyser is connected to the boards via 1/10/25/100 GbE links. The diagram also shows connections to NGC/EPC and various speed options (1/10/25/100 GbE)." data-bbox="422 683 1173 1153" src="9e727d0cdf88eca9085ecd457b33dafa_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure and Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Perform optical Point to Point port fibre disconnection.</li> <li>2. Measure and report the duration to raise the alarm.</li> <li>3. Perform optical Point to Point port fibre connection.</li> <li>4. Measure and report the duration to clear the alarm.</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1. “Ethernet link down” for optical Point to Point reported within 1 minute on step.</li> <li>2. “Ethernet link down” for optical Point to Point cleared within 1 minute on step 4</li> </ol> | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | <p>“Ethernet link down” alarm is reported xx minutes yy seconds.</p> <p>“Ethernet link down” alarm is cleared yy seconds</p> | | | + +4 + +#### 6.4.3.4 Dying Gasp (DG) + +This test is FFS. + +| | | | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Alarm & Monitoring.04 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Dying Gasp (DG) | | | +| <b>Test Objective:</b> | The aim of the test is to generate and clear a Dying Gasp (DG) of TNE alarm | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A network diagram showing two TNEs (TNE1 and TNE2) connected via an XHAUL LINK. TNE1 contains CU, DU, and RU blocks, and TNE2 contains CU and DU blocks. Both TNEs have multiple boards (Board 1, Board 2, etc.) connected to a Traffic generator/Analyser. The diagram also shows various data rates (1/10/25/100 GbE) and connections to NGC/EPC." data-bbox="422 645 1197 1137" src="4af85404f97995bd13a3aeec8db30471_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure and Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Perform the TNE1 or O-RU/DU/CU electrical power off.</li> <li>2. Measure and report the duration to raise the alarm on the TNE2 when the second TNE1 electrical power off</li> <li>3. Perform an TNE1 electrical power on</li> <li>4. Measure and report the duration to clear the alarm on the TNE2 when the TNE1 electrical power on</li> <li>5. Repeat the test few times.</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1- DG alarm reported within 1 minute on step 2</li> <li>2- DG alarm cleared within 2 minutes on step 4</li> </ol> | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | <p>DG alarm is reported xx minutes yy seconds.</p> <p>DG alarm is cleared xx minutes yy seconds</p> | | | + +#### 6.4.3.5 No Loss Of Signal alarm for Dying Gasp (DG) alarm + +This test is FFS. + +| | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Alarm & Monitoring.05 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | No Loss Of Signal alarm for Dying Gasp (DG) alarm | | | +| <b>Test Objective:</b> | The aim of the test is to check alarms reported when all/many links on one TNE report DG (Dying Gasp) alarm | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNEs (TNE1 and TNE2) connected via an XHAUL LINK. TNE1 contains CU, DU, and RU blocks, with Board 1 and Board 2. TNE2 contains CU and DU blocks, with Board 1 and Board 2. A Traffic generator/Analyser is connected to both TNEs via 1/10/25/100 GbE links. The diagram also shows connections to NGC/EPC." data-bbox="422 638 1197 1131" src="7457399ce2e6c08f79bdef5fabb2085c_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>1. Perform all/many TNE1 or O-RU/DU/CU electrical power off.</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Check if last link reports DG then no LOS alarm is reported (Check if this behaviour is enabled)</li> <li>2. Wait and check if no LOS alarm was reported</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | 1- No LOS alarm is reported | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | <p>DG alarm is reported xx minutes yy seconds</p> <p>DG alarm is cleared xx minutes yy seconds</p> | | | + +###### 1 6.4.3.6 Transceiver (SFP, QSFP,...) Rx optical power alarm threshold + +| | | | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Alarm & Monitoring.06 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Transceiver (SFP, QSFP,...) Rx optical power alarm threshold | | | +| <b>Test Objective:</b> | The aim of the test is to check if the transceiver received optical power parameters exceed warning high and low threshold then alarm is reported. When Rx signal is lower and higher than threshold defined then alarm is cleared properly. | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNE (Transceiver Network Element) blocks connected via a Variable Optical Attenuator. Each TNE contains Board 1 and Board 2. The boards are connected to a Traffic generator/Analyser. The diagram also shows CU (Control Unit), DU (Distributed Unit), and RU (Radio Unit) components, along with NGC/EPC (Next Generation Core/Evolved Packet Core) and XHAUL LINK connections. Optical power levels (1/10/25/100 GbE) are indicated for various connections." data-bbox="422 638 1212 1131" src="378dfcf67149d76177e41ba9e649fd14_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure and Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Configure Rx power parameter threshold high and low.</li> <li>2. Connect variable optical attenuator and change optical power. Rx signal must be higher than the threshold range.</li> <li>3. Measure and report the duration to raise the alarm.</li> <li>4. Check that alarm is cleared if Rx power is in the threshold range.</li> <li>5. Measure and report the duration to clear the alarm.</li> <li>6. Connect variable optical attenuator and change optical power. Rx signal must be lower than the threshold range.</li> <li>7. Measure and report the duration to raise the alarm.</li> <li>8. Check that alarm is cleared if Rx power is in the threshold range.</li> <li>9. Measure and report the duration to clear the alarm.</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1- Alarm "RX high power" reported within 1 minute on step 2</li> <li>2- Alarm "RX high power" cleared within 1 minute on step 4</li> <li>3- Alarm "RX low power" reported within 1 minute on step 6</li> <li>4- Alarm "RX low power" cleared within 1 minute on step 8</li> </ol> | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | <p>Alarm "RX high power" is reported xx second.</p> <p>Alarm "RX high power" is cleared xx second.</p> | | | + +| | | +|--|------------------------------------------------------------------------------------------| +| | Alarm “RX low power” is reported xx second.<br>Alarm “RX low power” is cleared xx second | +|--|------------------------------------------------------------------------------------------| + +#### 6.4.3.7 Transceiver (SFP, QSFP,...) Tx optical power alarm threshold + +| | | | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Alarm & Monitoring.07 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Transceiver (SFP, QSFP,...) Tx optical power alarm threshold | | | +| <b>Test Objective:</b> | The aim of the test is to check if the Ethernet transceiver emitted optical power parameters exceed warning high and low threshold then alarm is reported. When Tx signal is lower and higher than threshold defined then alarm is cleared properly. | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two RAN nodes connected via an XHAUL LINK. Each node contains a CU, DU, and RU stack, with a TNE (Transceiver Network Element) block below. The TNE block contains Board 1 and Board 2. A yellow line connects Board 1 of the left TNE to Board 1 of the right TNE. A green line connects Board 2 of the left TNE to Board 2 of the right TNE. A Traffic generator/Analyser block is connected to the bottom of both TNE blocks. Labels include '1 / 10 / 25 / 100 GbE' and 'NGC/EPC'." data-bbox="422 806 1165 1288" src="e3d80fb80ea2997b0a2e2c6494d48bd8_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure and Verifications needed:</b></p> <ol style="list-style-type: none"> <li>Configure Tx power parameter threshold high, Tx signal must be higher than the threshold range.</li> <li>Measure and report the duration to raise the alarm.</li> <li>Configure Tx power parameter threshold high, Tx signal must be in the threshold range.</li> <li>Check that alarm is cleared.</li> <li>Measure and report the duration to clear the alarm.</li> <li>Configure Tx power parameter threshold low, Tx signal must be lower than the threshold range.</li> <li>Measure and report the duration to raise the alarm.</li> <li>Configure Tx power parameter threshold low, Tx signal must be in the threshold range.</li> <li>Check that alarm is cleared.</li> <li>Measure and report the duration to clear the alarm.</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | + +| | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Pass/Fail Criteria:</b> | 1- Alarm “TX high power” reported within 1 minute on step 2<br>2- Alarm “TX high power” cleared within 1 minute on step 4<br>3- Alarm “TX low power” reported within 1 minute on step 7<br>4- Alarm “TX low power” cleared within 1 minute on step 9 | +| <b>Results</b> | <input type="checkbox"/> Pass <input type="checkbox"/> Pass w/X <input type="checkbox"/> Dropped <input type="checkbox"/> Blocked <input type="checkbox"/> Failed | +| <b>Test Output</b> | Alarm “TX high power” is reported xx second.<br>Alarm “TX high power” is cleared xx second.<br>Alarm “TX low power” is reported xx second.<br>Alarm “TX low power” is cleared xx second.<br>xx is to be defined by the vendor. | + +###### 1 6.4.3.8 Severity handling of alarms + +| | | | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Alarm & Monitoring.08 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Severity handling of alarms | | | +| <b>Test Objective:</b> | The aim of the test is to verify the severity handling of alarms | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNE (Test Network Element) blocks connected via an XHAUL LINK. Each TNE contains a stack of CU (Control Unit), DU (Data Unit), and RU (Radio Unit) components. Below the stack are two boards, Board 1 and Board 2. A Traffic generator/Analyser is connected to both boards via green lines labeled '1 / 10 / 25 / 100 GbE'. The RU components are connected to the NGC/EPC (Next Generation Core/ Evolved Packet Core) via green lines labeled '1 / 10 / 25 / 100 GbE'." data-bbox="422 571 1173 1041" src="43ac9db4eb883317998aa91613d7aa61_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure and Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Change the severity of an alarm.</li> <li>2. Generate the alarm.</li> <li>3. Check that the alarm is reported with the configured severity level.</li> <li>4. Change the severity of the selected alarm with the default value.</li> <li>5. Generate the alarm.</li> <li>6. Check that the alarm is reported with the configured severity level.</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | Alarm must be reported with the configured severity level on step 3 and step 6 | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | “ | | | + +#### 6.4.3.9 Port-ID (IDentification) maintenance + +| | | | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Alarm & Monitoring.08 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Port-ID (IDentification) maintenance | | | +| <b>Test Objective:</b> | The aim of the test is to check the ID feature | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNE (Network Traffic Element) blocks connected via an XHAUL LINK. Each TNE contains two boards (Board 1 and Board 2). The left TNE is connected to a CU (Control Unit) and DU (Data Unit) block. The right TNE is connected to a CU and DU block. A Traffic generator/Analyser is connected to both TNEs via green lines labeled '1 / 10 / 25 / 100 GbE'. The diagram also shows a NGC/EPC (Next Generation Core/Edge Computing Platform) block connected to the right TNE." data-bbox="422 571 1173 1041" src="43ac9db4eb883317998aa91613d7aa61_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure and Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Configure Port-ID at TNE</li> <li>2. Check if Port-ID modification can be done with TNE in administrative state up.</li> <li>3. Connect an Ethernet teste on the link.</li> </ol> | | | +| <b>Test Configuration</b> | Xhaul traffic and RAN services configuration | | | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1. Port-ID creation and modification should be possible without service impact for customer on step 2</li> <li>2. Port-ID should be retrieved on step 3</li> </ol> | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | | | | + +# 7 WDM-based Fronthaul Transport Testing + +Fronthaul in O-RAN is defined as the connectivity in the RAN infrastructure between the Distributed Unit (O-DU) and Radio Unit (O-RU). + +## 7.1 Fronthaul Testing use cases. + +### 7.1.1 Transmit Power + +| Test ID | DWDM.HEE.01 | Classification | Functionality | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Transmitting power at the DWDM head end equipment (HEE) | | | +| Test Objective: | To test transmitting power levels at the HEE | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <p>Refer to O-RAN.WG9.WDM-v01.00, Section 2.3 Semi-Active WDM system</p> <img alt="Diagram of WDM HEE/O-DU test topology. It shows a Client connected to a Network (WDM HEE/O-DU) via a series of transmitters (Tx) and receivers (Rx). The Client has Tx1, Tx2, ..., Txn. The Network has Rx1, Rx2, ..., Rxn. The Network is connected to an OM/OD (Optical Multiplexer/Demultiplexer). The OM/OD is connected to a reference point (Ref. 3) which is connected to O-DU and O-RU. The O-DU and O-RU are connected via a fiber link. The O-DU and O-RU are connected to an OPM (Optical Power Meter) and an OSA (Optical Spectrum Analyzer). The diagram also shows reference points Ref. 1 and Ref. 2 for power measurement." data-bbox="414 1030 1388 1456" src="11fc8dc6585cff5a0e2a0eb7a415daaa_img.jpg"/> <p style="text-align: center;">WDM HEE/O-DU</p> | | | +| Required tester | Optical power meter (OPM), optical spectrum analyzer (OSA) | | | +| Test Configuration | 1. Disable all the other transmitters (e.g. Tx <sub>n</sub> ) which are NOT under test; | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect the OPM and OSA to the reference points shown in the above test configuration.</li> <li>2. Read the power level of Ref. 1 (Client Tx).</li> <li>3. Read the power level of Ref. 2 (Network Tx).</li> <li>4. Read the power level of Ref. 3 (Network Port of OM/OD)</li> <li>5. Measure the center frequency and the optical spectrum at Ref. 3 (Network Port of OM/OD)</li> <li>6. To carry out the procedure for all the other transmitters.</li> </ol> | | | + +| | <b><u>Verifications needed:</u></b> <ol style="list-style-type: none"> <li>Record Tx power readings from the host network management.</li> </ol> | | | | | | | | | | | | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------------------------|-----------------------|--------|--|--|---------|--|--|-------|--|--| +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>Tx power at Ref. 1 should be -8 to 0 dBm.</li> <li>Tx power at Ref. 2 complies with O-RAN.WG9.WDM-v01.00, Table 6-10, depending on the pluggable variants.</li> <li>Tx power at Ref. 3 should be within the range of Ref. 2 deducting maximum insertion loss of 4.6 dB.</li> <li>Optical spectrum complies with O-RAN.WG9.WDM-v01.00, Table 6-10, depending on the pluggable variants.</li> </ol> | | | | | | | | | | | | | +| <b>Test Output</b> | <table border="1"> <thead> <tr> <th>Interface</th> <th>Network Mgmt.<br/>Tx power (dBm)</th> <th>OPM<br/>Tx power (dBm)</th> </tr> </thead> <tbody> <tr> <td>Client</td> <td></td> <td></td> </tr> <tr> <td>Network</td> <td></td> <td></td> </tr> <tr> <td>OM/OD</td> <td></td> <td></td> </tr> </tbody> </table> | Interface | Network Mgmt.<br>Tx power (dBm) | OPM<br>Tx power (dBm) | Client | | | Network | | | OM/OD | | | +| Interface | Network Mgmt.<br>Tx power (dBm) | OPM<br>Tx power (dBm) | | | | | | | | | | | | +| Client | | | | | | | | | | | | | | +| Network | | | | | | | | | | | | | | +| OM/OD | | | | | | | | | | | | | | +| | | | | | | | | | | | | | | + +### 7.1.2 Receive Sensitivity + +| Test ID | DWDM.HEE.02 | Classification | Functionality | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Receiving sensitivity at the DWDM head end equipment (HEE) | | | +| Test Objective: | To test received power level and receiving sensitivity at the HEE | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | Refer to O-RAN.WG9.WDM-v01.00, Section 2.3 Semi-Active WDM system <div data-bbox="411 723 1436 1236" data-label="Diagram"> <p>Image: Test topology diagram for Receive Sensitivity. The diagram shows a Client (Tx/Rx pairs) connected to a Network (Tx/Rx pairs) via a WDM HEE/O-DU. A Traffic Tester is connected to the Client via a reference point (Ref. 1). An Optical Power Meter (OPM) is connected to the Client via a reference point (Ref. 2). A Variable Optical Attenuator (VOA) is connected to the Network via a reference point (Ref. 3). The WDM HEE/O-DU is represented by a trapezoidal block labeled OM/OD. The Client and Network are represented by boxes containing Tx/Rx pairs. The diagram also shows O-DU and O-RU connections on the right side.</p> </div> | | | +| Required tester | Optical power meter (OPM), variable optical attenuator (VOA), traffic tester (eCPRI) | | | +| Test Configuration | | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect the OPM, VOA, and traffic tester to the reference points shown in the above test configuration.</li> <li>2. Disable all the other transmitters (e.g. Tx<sub>n</sub>) on both O-DU and O-RU ends which are NOT under test.</li> <li>3. Configure the traffic tester accordingly to terminate the traffic flow from the O-RU.</li> <li>4. Gradually increase the attenuation of VOA, until the BER is stable at the threshold of 1e-12 for 10 minutes.</li> <li>5. Read the Tx/Rx power level of Ref. 1 (Client Tx/Rx);</li> <li>6. Read the Rx power level of Ref. 2 (Network Rx).</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Verify the Tx/Rx power levels between the traffic tester and the HEE Client are in the dynamic range of client transceivers.</li> <li>2. Record Rx power readings from the host network management.</li> </ol> | | | + +| | | | | +|---------------------|------------------------------------------------------------------------------------------------------------|---------------------------------|-----------------------| +| Pass/Fail Criteria: | 1. Rx power at Ref. 2 complies with O-RAN.WG9.WDM-v01.00, Table 6-10, depending on the pluggable variants. | | | +| Test Output | | | | +| | Interface | Network Mgmt.<br>Rx power (dBm) | OPM<br>Rx power (dBm) | +| | Network | | | +| | | | | + +###### 1                      7.1.3 Auto-tuning test + +2 + +| | | | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test ID | WDM.auto-tuning.01 | Classification | Functionality | +| Test Title | Paired frequency tuning at tail end (TE) | | | +| Test Objective: | To verify if the tail-end transceiver can be auto-tuned to the connected filter port | | | +| Pre-Req | Optical transceivers supporting paired auto-tuning | | | +| Test Topology: | <p>Applicable to O-RAN.WG9.WDM-v01.00, Passive, Semi-Active, and Active WDM fronthaul system</p> <img alt="Diagram of WDM HEE/O-DU and WDM TEE/O-R topology. The diagram shows a Client connected to a Network (WDM HEE/O-DU) via multiple transceivers (Tx1/Rx1 to Txn/Rxn). A Traffic Tester is connected to the Client transceivers (Ref. 1). The Network transceivers are connected to an OM/OD (Ref. 2). The OM/OD is connected to an O-DU/O-RU (Ref. 3). The O-DU/O-RU is connected to another OM/OD (Ref. 4), which is then connected to a Network (WDM TEE/O-R) and a Client (Tx1/Rx1 to Txn/Rxn)." data-bbox="406 1249 1442 1630" src="05d0abedf36115f32c97f12aa3771df3_img.jpg"/> <p style="text-align: center;">WDM HEE/O-DU                      WDM TEE/O-R</p> | | | +| Required tester | Optional traffic tester (eCPRI) | | | +| Test Configuration | | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect the client and network transceivers at the WDM HEE/O-DU according to the test topology above.</li> <li>2. At the WDM HEE/O-DU, provision the frequency of all the populated HE Network transceiver (Tx<sub>1</sub>/Rx<sub>1</sub> ... Tx<sub>n</sub>/Rx<sub>n</sub>), as well as the paired frequency for the TE transceivers.</li> </ol> | | | + +| | <ol style="list-style-type: none"> <li>Enable the channel ports (laser on) and optionally testing traffic.</li> <li>Plug and enable the TE transceiver under test into the O-RU (passive WDM) or remote WDM equipment.</li> <li>Connect fibers between the TE transceiver and one of the provisioned OM/OD ports.</li> <li>Monitor and read the Rx signal at the corresponding HE transceiver.</li> <li>Repeat Step 5 and 6 for the other OM/OD ports.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>Verify whether the TE transceiver can be automatically tuned to the correct uplink frequency.</li> <li>Verify whether the channel status at the WDM HEE/O-DU is “link up” and read the received optical power.</li> <li>Record the time duration from the moment connecting the OM/OD port to the TE transceiver being auto tuned.</li> <li>Optionally verify whether the traffic is resumed. The traffic needs to be looped back from the WDM TEE/O-RU.</li> </ol> | | | | | | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------|----------------|-------------|----------------|--|--|--|--| +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>After power cycle or being reconnected to a new OM/OD port, the TE transceiver is automatically tuned to the correct uplink frequency.</li> <li>Rx power at Ref. 2 complies with O-RAN.WG9.WDM-v01.00, Table 6-10, depending on the pluggable variants.</li> <li>Optionally the traffic can be resumed.</li> </ol> | | | | | | | | | +| <b>Test Output</b> | <table border="1"> <thead> <tr> <th>TE Channel Frequency</th> <th>Tuning Time</th> <th>Link Status</th> <th>Rx Power at HE</th> </tr> </thead> <tbody> <tr> <td> </td> <td> </td> <td> </td> <td> </td> </tr> </tbody> </table> | TE Channel Frequency | Tuning Time | Link Status | Rx Power at HE | | | | | +| TE Channel Frequency | Tuning Time | Link Status | Rx Power at HE | | | | | | | +| | | | | | | | | | | + +### 7.1.4 Crosstalk testing + +| Test ID | WDM.crosstalk.01 | Classification | Functionality | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | WDM Xhaul transport inter-channel crosstalk | | | +| Test Objective: | To verify if the OM/OD meets the isolation specification of the WDM transport link | | | +| Pre-Req | | | | +| Test Topology: | <p>Applicable to O-RAN.WG9.WDM-v01.00, Passive, Semi-Active, and Active WDM fronthaul system</p> <div style="text-align: center;"> <img alt="Diagram of WDM Xhaul transport inter-channel crosstalk test topology. It shows a WDM HEE/O-DU on the left and a WDM TEE/O-RU on the right. The HEE/O-DU contains a TRx 1 block with Tx and Rx ports. The Tx port is connected to an OM (Optical Multiplexer) block. The Rx port is connected to an OSA (Optical Spectrum Analyzer) block. The OM is connected to an OD (Optical Demultiplexer) block. The OD has multiple output ports. One output port is connected to an OSA block. Another output port is connected to an OSA block. A third output port is connected to an OSA block. The OSA blocks are used to measure the spectrum peak power at Tx (P in dBm), the insertion loss (IL in dB), the adjacent channel isolation (Ia in dB), and the non-adjacent channel isolation (Ina in dB). The diagram also includes two spectral plots: one for the HEE/O-DU showing a single peak at power P, and one for the TEE/O-RU showing multiple peaks with labels for IL, Ia, and Ina." data-bbox="438 694 1396 1153" src="0cd69b579e669d40e6e0ce6b4b6bd6d0_img.jpg"/> <br/> <span style="margin-right: 200px;">WDM HEE/O-DU</span> <span>WDM TEE/O-RU</span> </div> | | | +| Required tester | Optical spectrum analyzer (OSA) | | | +| Test Configuration | <ol style="list-style-type: none"> <li>Definitions of <math>IL</math>, <math>I_a</math>, and <math>I_{na}</math> are referred to ITU-T G.671</li> <li>OSA shall be capable of a sensitivity of at least -65 dBm</li> </ol> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>Provision and enable a WDM transceiver for the respective WDM solution (e.g., DWDM, MWDM);</li> <li>Use the OSA to measure the spectrum peak power at Tx (<math>P</math> in dBm);</li> <li>Connect the transceiver to the OM, and only a short jumper cable is needed between the OM and the OD.</li> <li>Connect to the OSA to the OD output port of the wanted channel, and measure the spectrum peak power to calculate the insertion loss (<math>IL</math> in dB);</li> <li>Connect to the OSA to one of the adjacent channel ports of the wanted one, and measure the spectrum peak power to calculate the adjacent channel isolation (<math>I_a</math> in dB);</li> <li>Connect to the OSA to any of the other OD output ports and measure the spectrum peak power to calculate the non-adjacent channel isolation (<math>I_{na}</math> in dB).</li> </ol> | | | + +| | <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. OSA settings shall be always kept the same.</li> <li>2. For the measurement of each wanted channel, at least one <i>I<sub>a</sub></i> and one <i>I<sub>na</sub></i> shall be measured.</li> <li>3. If more than one <i>I<sub>a</sub></i> or <i>I<sub>na</sub></i> are measured, always take the smallest (worst) value from the result set.</li> </ol> | | | | | | | | | | | | | +|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------|-------------|----------------------|-----------------------|----------------------|-----------------------|-------------------|---------------------|--|--|--|--| +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1. Depending on the type of WDM OM/OD, <i>IL</i>, <i>I<sub>a</sub></i>, and <i>I<sub>na</sub></i> shall be compliant with O-RAN.WG9.WDM-v01.00, Table 9-10.</li> <li>2. The actual tolerable inter-channel crosstalk (<i>C<sub>c</sub></i> in dB) for 100GHz-spaced DWDM is specified in G.698.1, Tables 8-1 to 8-4. <i>C<sub>c</sub></i> can be calculated following:<br/> <math display="block">C_c = d + 10 \log \left[ 2 \times 10^{\frac{-I_a}{10}} + (k - 3) 10^{\frac{-I_{na}}{10}} \right]</math> where <i>d</i> is the maximum allowable power difference of a particular transceiver type specified in O-RAN.WG9.WDM-v01.00</li> </ol> | | | | | | | | | | | | | +| <b>Test Output</b> | <table border="1"> <thead> <tr> <th>WDM Type</th> <th>Transceiver</th> <th>Channel</th> <th><i>IL</i></th> <th><i>I<sub>a</sub></i></th> <th><i>I<sub>na</sub></i></th> </tr> </thead> <tbody> <tr> <td>e.g. DWDM or MWDM</td> <td>e.g. 10G, 25G, BiDi</td> <td></td> <td></td> <td></td> <td></td> </tr> </tbody> </table> | WDM Type | Transceiver | Channel | <i>IL</i> | <i>I<sub>a</sub></i> | <i>I<sub>na</sub></i> | e.g. DWDM or MWDM | e.g. 10G, 25G, BiDi | | | | | +| WDM Type | Transceiver | Channel | <i>IL</i> | <i>I<sub>a</sub></i> | <i>I<sub>na</sub></i> | | | | | | | | | +| e.g. DWDM or MWDM | e.g. 10G, 25G, BiDi | | | | | | | | | | | | | +| | | | | | | | | | | | | | | + +| | | | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test ID | WDM.crosstalk.02 | Classification | Functionality | +| Test Title | WDM Xhaul transport interferometric crosstalk | | | +| Test Objective: | To verify if the OM/OD meets the isolation specification of a WDM transport link with add/drop nodes | | | +| Pre-Req | | | | +| Test Topology: | <p>Applicable to O-RAN.WG9.WDM-v01.00, Passive, Semi-Active, and Active WDM fronthaul system</p> <img alt="Diagram of WDM Xhaul transport interferometric crosstalk test topology. The diagram shows a WDM HEE/O-DU on the left and a WDM TEE/O-RU on the right. The HEE/O-DU contains a TRx 1 block with Tx and Rx ports, and an OSA block. The signal path goes from TRx 1 Tx through an OM (Optical Multiplexer) block. The OM has two outputs: one to OD 1 (Optical Drop) and one to OD n (Optical Drop). OD 1 has an OSA block connected to its output. OD n has an OSA block connected to its output. The TEE/O-RU contains an OSA block. The signal path from OD n goes to the TEE/O-RU OSA block. The diagram also includes two spectral plots: one showing a single peak with power P, and another showing a peak with power Ii and a small side peak with power IL." data-bbox="430 627 1420 1142" src="601ca86786424c6b19e1f99f315b4e1a_img.jpg"/> <p>WDM HEE/O-DU</p> <p>WDM TEE/O-RU</p> | | | +| Required tester | Optical spectrum analyzer (OSA) | | | +| Test Configuration | OSA shall be capable of a sensitivity of at least -65 dBm | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Provision and enable a WDM transceiver for the respective WDM solution (e.g., DWDM, MWDM), of which the channel is dropped at the measured OD (i.e. OD 1 in the test example);</li> <li>2. Follow the procedure specified in WDM.crosstalk.01 (Step 2 to 6).</li> <li>3. Measure the spectrum peak power at the OD network port to calculate the isolation (<math>I_i</math>) for interferometric crosstalk.</li> </ol> <p><b>Note:</b> The signal from the first source will be extinguished by the OADMs where the channel is dropped, and the interferometric crosstalk will be dominated by the performance of the last OADM that dropped and added that channel. This interferometric crosstalk, therefore, does not constrain the number of OADMs in a link. [Ref to G.698.1]</p> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. OSA settings shall be always kept the same.</li> <li>2. For the measurement of each wanted channel, at least one <math>I_a</math> and one <math>I_{na}</math> shall be measured.</li> </ol> | | | + +| | 3. If more than one $I_a$ or $I_{na}$ are measured, always take the smallest (worst) value from the result set. | | | | | | | | | | | | | | | +|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------|-------------|-----------------|----------|-------|----------|-------|-------------------|---------------------|--|--|--|--|--| +| <b>Pass/Fail Criteria:</b> | 1. Depending on the type of WDM OM/OD, $IL$ , $I_a$ , and $I_{na}$ shall be compliant with O-RAN.WG9.WDM-v01.00, Table 9-10.<br>2. The actual tolerable interferometric crosstalk for 100GHz-spaced DWDM is specified in G.698.1, Tables 8-1 to 8-4. | | | | | | | | | | | | | | | +| <b>Test Output</b> | <table border="1"> <thead> <tr> <th>WDM Type</th><th>Transceiver</th><th>Dropped Channel</th><th><math>IL</math></th><th><math>I_a</math></th><th><math>I_{na}</math></th><th><math>I_i</math></th></tr> </thead> <tbody> <tr> <td>e.g. DWDM or MWDM</td><td>e.g. 10G, 25G, BiDi</td><td></td><td></td><td></td><td></td><td></td></tr> </tbody> </table> | WDM Type | Transceiver | Dropped Channel | $IL$ | $I_a$ | $I_{na}$ | $I_i$ | e.g. DWDM or MWDM | e.g. 10G, 25G, BiDi | | | | | | +| WDM Type | Transceiver | Dropped Channel | $IL$ | $I_a$ | $I_{na}$ | $I_i$ | | | | | | | | | | +| e.g. DWDM or MWDM | e.g. 10G, 25G, BiDi | | | | | | | | | | | | | | | +| | | | | | | | | | | | | | | | | + +1 + +### 7.1.5 Latency Test + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------| +| <b>Test ID</b> | WDM.latency.01 | <b>Classification</b> | Characterization | +| <b>Test Title</b> | WDM Xhaul transport latency measurement | | | +| <b>Test Objective:</b> | To measure the PHY latency from an optical transceiver to the other of the WDM transport link | | | +| <b>Pre-Req</b> | | | | +| <b>Test Topology:</b> | <p>Applicable to O-RAN.WG9.WDM-v01.00, Passive, Semi-Active, and Active WDM fronthaul system</p> <img alt="Test Topology Diagram: A block diagram showing the test setup. A 'Tx electrical data pattern' enters 'TRx 1' (part of 'WDM HEE/O-DU'). The signal goes through an 'OM' block to an 'OD' block, then to 'TRx 2' (part of 'WDM TEE/O-RU'). The 'Rx electrical data pattern' is captured. A 'BER Tester' receives the 'Tx pattern trigger' and sends a 'Loopback calibration' signal to a 'Digital Oscilloscope', which also receives the 'Rx electrical data pattern'." data-bbox="414 1366 1340 1948" src="8ec5843787e762fffcc9a448d841fb26_img.jpg"/> | | | +| <b>Required tester</b> | General purpose bit error rate tester (BERT); highspeed digital oscilloscope (OSC) | | | + +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>The BERT is able to customize data pattern with a recurring period of preferably a magnitude order higher than the expected latency.</li> <li>The OSC has adequate bandwidth to sample the data pattern.</li> <li>For optical transceivers integrated with CDR, the transmitted data rate needs to be in the range of the CDR clock rate.</li> </ol> | | | | | | | | | | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------|-------------|-------------|---------|---------|-------------------|--|---------------------|--|--| +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>Customize the transmitted data pattern with a recurring period of a magnitude order higher than the expected latency (e.g. PRBS pattern with a tail of consecutive “0” symbols or alternating “1” and “0” sequence);</li> <li>Use one of the OSC channels to measure the transmitted pattern trigger output of the BERT as the reference signal, and another channel to measure the received data pattern.</li> <li>Before the actual link measurement, connect Tx cable (from the BERT) and Rx cable (to the OSC) together for the loopback calibration, measuring the loopback offset between the Tx trigger and the unique pattern identified in the Rx data.</li> <li>Connect the exact same Tx and Rx cable with the two optical transceivers under test, as well as the WDM link in between.</li> <li>Measure again the offset between the Tx trigger and the identified Rx data, and subtract the loopback offset to obtain the actual link latency.</li> <li>The same procedure can be also applied to the other transmission direction.</li> </ol> | | | | | | | | | | | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>Informative result only</li> </ol> | | | | | | | | | | | +| <b>Test Output</b> | <table border="1"> <thead> <tr> <th>WDM Type</th> <th>Filter Type</th> <th>Transceiver</th> <th>Channel</th> <th>Latency</th> </tr> </thead> <tbody> <tr> <td>e.g. DWDM or MWDM</td> <td></td> <td>e.g. 10G, 25G, BiDi</td> <td></td> <td></td> </tr> </tbody> </table> | WDM Type | Filter Type | Transceiver | Channel | Latency | e.g. DWDM or MWDM | | e.g. 10G, 25G, BiDi | | | +| WDM Type | Filter Type | Transceiver | Channel | Latency | | | | | | | | +| e.g. DWDM or MWDM | | e.g. 10G, 25G, BiDi | | | | | | | | | | + +| | | | | +|------------------------|-------------------------------------------------------------------------------------------|-----------------------|------------------| +| <b>Test ID</b> | WDM.latency.02 | <b>Classification</b> | Characterization | +| <b>Test Title</b> | Fiber latency and asymmetry measurement | | | +| <b>Test Objective:</b> | To measure the fiber latency and asymmetry for a particular x-haul PHY link | | | +| <b>Pre-Req</b> | | | | +| <b>Test Topology:</b> | Applicable to O-RAN.WG9.WDM-v01.00, Passive, Semi-Active, and Active WDM fronthaul system | | | + +![Diagram illustrating OTDR measurement setup and results. The top part shows two configurations: one where the OTDR is connected to the O-DU Side and another where it is connected to the O-RU Side. The bottom part shows a graph of Reflectance vs. RT Time with labels for Rayleigh scattering, Lossy splice, and Demarcation Reflector.](d2c91350916f33bd65522fd8db875db4_img.jpg) + +The diagram illustrates the OTDR measurement setup and results. The top part shows two configurations: one where the OTDR is connected to the O-DU Side and another where it is connected to the O-RU Side. The bottom part shows a graph of Reflectance vs. RT Time with labels for Rayleigh scattering, Lossy splice, and Demarcation Reflector. + +**OTDR Measurement Setup:** + +- O-DU Side:** The OTDR is connected to the O-DU Side. The probe signal is sent to the O-RU Side, and the response is received back at the O-DU Side. The round-trip time is indicated. +- O-RU Side:** The OTDR is connected to the O-RU Side. The probe signal is sent to the O-DU Side, and the response is received back at the O-RU Side. The round-trip time is indicated. + +**OTDR Measurement Results:** + +The graph shows Reflectance vs. RT Time. The curve starts at a high reflectance level, decreases linearly (Rayleigh scattering), and then shows a sharp drop (Lossy splice). The curve then rises sharply (Demarcation Reflector) and finally drops to zero (Physical fibre termination). The time axis is labeled with $0$ , $\tau_0$ , and $\tau_{DR}$ . + +Diagram illustrating OTDR measurement setup and results. The top part shows two configurations: one where the OTDR is connected to the O-DU Side and another where it is connected to the O-RU Side. The bottom part shows a graph of Reflectance vs. RT Time with labels for Rayleigh scattering, Lossy splice, and Demarcation Reflector. + +#### Required tester + +General purpose optical time-domain reflectometer (OTDR) + +#### Test Configuration + +1. The accuracy of the measurement depends on the length of the OTDR pulse, usually in a range of few nanoseconds. +2. To achieve a sufficient signal-to-noise ratio, longer probe pulses may be required for longer fiber links, because of a higher loss. +3. In case of using a correlated OTDR, a bit sequence at a rate of a few Gbit/s can be used as the probe signal. The reflected signals are then cross-correlated with the transmitted bit pattern, improving the resolution of this correlated OTDR to picoseconds. + +| | <p>4. For measuring any wavelength asymmetry, CWDM, DWDM or tunable OTDR source is required.</p> <p>Note 1: Link asymmetry compensation is elaborated in Appendix IV, ITU-T G.8271/Y.1366 (03/2020).</p> <p>Note 2: OTDR is specified as a fiber link monitoring for WDM systems in ITU-T G.697.</p> | | | | | | | | | | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|-------------|-----------|-----|-----------|--|------------------------|--|--|--| +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Insert the OTDR at the optical transmitter interface (e.g.O-DU/CSR output, WDM HEE Tx, etc.);</li> <li>2. If possible, insert also a demarcation reflector in front of the actual fiber termination;</li> <li>3. Configure the pulse length, wavelength, measurement duration etc. of the OTDR, according to the expected link range;</li> <li>4. The round-trip latency can be calculated between the start event of pulse launch and the end/demarcation reflective event, and the one-way latency of the measured link is exactly half of it;</li> <li>5. In case of measuring the latency of multiple wavelengths, change the OTDR wavelength accordingly and repeat Step 3-4;</li> <li>6. In case of measuring the latency of multiple links from the same transmitter side, switch the OTDR connection to another link and repeat Step 3-5.</li> </ol> | | | | | | | | | | | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1. Informative result only</li> </ol> | | | | | | | | | | | +| <b>Test Output</b> | <table border="1" style="width: 100%;"> <thead> <tr> <th style="width: 20%;">Link</th> <th style="width: 20%;">Transceiver</th> <th style="width: 20%;">Channel</th> <th style="width: 20%;">RTL</th> <th style="width: 20%;">Asymmetry</th> </tr> </thead> <tbody> <tr> <td></td> <td>e.g. 10G,<br/>25G, BiDi</td> <td></td> <td></td> <td></td> </tr> </tbody> </table> | Link | Transceiver | Channel | RTL | Asymmetry | | e.g. 10G,<br>25G, BiDi | | | | +| Link | Transceiver | Channel | RTL | Asymmetry | | | | | | | | +| | e.g. 10G,<br>25G, BiDi | | | | | | | | | | | + +### 7.1.6 OAM Test + +Applicable to O-RAN.WG9.WDM-v01.00, in semi-active or active fronthaul WDM systems, active WDM equipment on the O-DU side is configured to transmit management requests to O-RUs and manage the colored optical modules within the O-RUs. The optical modules in O-RUs are configured to send back management request responses to the active WDM equipment. The + +management request responses carry the status information of the colored optical modules in the O-RUs in the table of Key Performance Indicators in section 6.1 of O-RAN.WG9.WDM-v01.00, including the wavelength, driving voltage, driving current, the launched optical power of the transmitter, the received optical power of the receiver, etc. In this way, OAM tests are crucial for the interoperability between optical modules and active WDM equipment from different vendors. + +| | | | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------| +| <b>Test ID</b> | WDM.OAM.01 | <b>Classification</b> | Characterization | +| <b>Test Title</b> | OAM test for optical module OAM data link layer | | | +| <b>Test Objective:</b> | To test the OAM data link communication of the optical modules | | | +| <b>Pre-Req</b> | | | | +| <b>Test Topology:</b> | <p>Applicable to O-RAN.WG9.WDM-v01.00, optical modules.</p> <img alt="Test topology diagram showing two test boards connected via a 10km fiber link. Test board 1 (left) has a TRx1 port connected to a 50:50 splitter. The splitter's other output goes to a VOA, then a WDM component, then a 10km fiber, then another WDM component, then an Rx port of Test board 2 (right). A BER tester is connected to the Tx port of Test board 1 and the Rx port of Test board 2. An OPM is connected to the Tx port of Test board 1. Both test boards are connected to their respective testing management systems." data-bbox="416 958 1150 1249" src="dfa50375f581d1bb643347e6642a9b52_img.jpg"/> <p>An optical link consists of WDM components, like MUX/DEMUX and 10km optical fiber, which are used to connect optical modules at two ends to simulate the Fronthaul optical transport channel.</p> <p>Each optical module is installed on a test board like a transponder, on which a management system installs. The information of optical modules can be configured and read by the test boards through the management system.</p> <p>To test the active function specified in section 6.1 of O-RAN.WG9.WDM-v01.00, the optical module on one side can receive and verify the OAM information from the optical module configured by the corresponding management system on the other side, and send back the verification result to the optical module on the other side.</p> <p>To test the configuration and inquiry functions specified in section 6.1 of O-RAN.WG9.WDM-v01.00, the optical module on one side can also be configured by the corresponding testing management system to send the testing OAM configuration or inquiry messages to the optical module on the other side. Then, the optical module on one side can receive and verify the corresponding OAM responses from the optical module on the other side. If the corresponding OAM responses are correct, the optical modules can send the results to the optical module on the other side.</p> | | | +| <b>Required tester</b> | General purpose bit error rate tester (BERT); digital oscilloscope; Optical power meter (OPM); variable optical attenuator (VOA); test board; | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>Connect the OPM, VOA, splitters and BER tester to the reference points shown in the above test configuration.</li> </ol> | | | + +| | | +|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>2. Configure the BERT to simulate service information transmission.</li> <li>3. Adjust the VOA to make the attenuation of the link meet the requirements of the power budget.</li> <li>4. Configure OAM connections between the testing management systems and TRxs.</li> </ol> | +| <b>Procedure:</b> | <ol style="list-style-type: none"> <li>1. Verify that the service channel is working properly through the BERT.</li> <li>2. Start OAM frame statistics at the testing management system and test for 10 minutes to check the number of bits sent and received, and the number of error frames in the testing management systems.</li> </ol> | +| <b>Pass/Fail Criteria:</b> | No alarms, no error frames, and the number of sent and received frames is the same. | +| <b>Test Output</b> | The OAM data link communication of the optical modules is OK. | +| | | + +1 + +| | | | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------| +| <b>Test ID</b> | WDM.OAM.02 | <b>Classification</b> | Characterization | +| <b>Test Title</b> | OAM test for active WDM equipment OAM data link layer | | | +| <b>Test Objective:</b> | To test the OAM data link communication of active WDM equipment and optical modules. | | | +| <b>Pre-Req</b> | | | | +| <b>Test Topology:</b> | <p>Applicable to O-RAN.WG9.WDM-v01.00, active WDM equipment for semi-active WDM system and active WDM system.</p> <img alt="Test Topology Diagram: The diagram shows the test setup between two sides: O-RU side and O-DU side. On the O-RU side, Test board 1 is connected to a Testing management system 1. Test board 1 has TRx 1 and Rx Tx ports. A 50:50 splitter is connected to TRx 1, with one output going to an OPM (Optical Power Meter) and the other to a VOA (Variable Optical Attenuator). The VOA is connected to a WDM module. On the O-DU side, there is an Active WDM module containing an MCU, two PDs (Photodetectors), and two splitters. A 10km fiber connects the WDM module on the O-RU side to the Active WDM module on the O-DU side. The Active WDM module is connected to Test board 2, which has Rx Tx and TRx 2 ports. Test board 2 is connected to a Testing management system 2. A BER tester is connected to the Rx Tx port of Test board 1 and the Rx Tx port of Test board 2." data-bbox="419 1240 1361 1547" src="ba0d359b5273771c851dddf0e8c198c0_img.jpg"/> <p style="text-align: center;">O-RU side <span style="margin-left: 200px;">O-DU side</span></p> | | | +| <b>Required tester</b> | General purpose bit error rate tester (BERT); digital oscilloscope; Optical power meter (OPM); variable optical attenuator (VOA); test board; | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Connect the OPM, VOA, splitters and BERT tester to the reference points shown in the above test configuration.</li> <li>2. Configure the BERT to simulate service information transmission.</li> <li>3. Adjust the VOA to make the attenuation of the link meet the requirements of the power budget.</li> <li>4. Configure OAM connections between testing management system and TRx.</li> </ol> | | | +| <b>Procedure:</b> | <ol style="list-style-type: none"> <li>1. Verify that the service channel is working properly through the BERT.</li> <li>2. Verify that the OAM data link communication of optical modules is OK through the testing management systems.</li> </ol> | | | + +| | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------| +| | 3. Check through management systems whether the active WDM equipment can receive OAM messages from optical modules at O-RU side. | +| <b>Pass/Fail Criteria:</b> | The OAM messages from optical modules at O-RU side can be received correctly by active WDM equipment. | +| <b>Test Output</b> | The OAM data link communication of the active WDM equipment and optical modules is OK. | +| | | + +1 + +| | | | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------| +| <b>Test ID</b> | WDM.OAM.03 | <b>Classification</b> | Characterization | +| <b>Test Title</b> | OAM test for functions of active WDM equipment service layer | | | +| <b>Test Objective:</b> | To test the OAM service layer functions of active WDM equipment. | | | +| <b>Pre-Req</b> | | | | +| <b>Test Topology:</b> | <p>Applicable to O-RAN.WG9.WDM-v01.00, active WDM equipment for semi-active WDM system and active WDM system.</p> <img alt="Test Topology Diagram: The diagram shows the test setup between the O-RU side and the O-DU side. On the O-RU side, Test board 1 (connected to Testing management system 1) has TRx 1 (Tx) connected to a 50:50 splitter. The other output of the 50:50 splitter goes to an OPM. The output of the OPM goes through a VOA and then a WDM component. On the O-DU side, a 10km fiber connects the WDM component to another WDM component. This second WDM component is connected to a dashed box labeled 'Active WDM', which contains an MCU, a PD, a splitter, and a Pb. The output of the Active WDM goes through a Tx and is connected to TRx 2 on Test board 2 (connected to Testing management system 2). A BER tester is connected to the Tx of Test board 1 and the Rx of Test board 2." data-bbox="419 952 1361 1256" src="e197ca4cad293a99c3ec914651cb2642_img.jpg"/> <p style="text-align: center;">O-RU side <span style="margin-left: 200px;">O-DU side</span></p> | | | +| <b>Required tester</b> | General purpose bit error rate tester (BERT); digital oscilloscope; Optical power meter (OPM); variable optical attenuator (VOA); test board; | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Connect the OPM, VOA, splitters and BER tester to the reference points shown in the above test configuration.</li> <li>2. Configure the BERT to simulate service information transmission.</li> <li>3. Adjust the VOA to make the attenuation of the link meet the requirements of the power budget.</li> <li>4. Configure OAM connections between testing management systems and TRxs.</li> </ol> | | | +| <b>Procedure:</b> | <ol style="list-style-type: none"> <li>1. Verify that the service channel is working properly through the BERT.</li> <li>2. Verify that the OAM data link communication of optical modules is OK.</li> <li>3. Verify that the OAM data link communication of the active WDM equipment and optical modules is OK.</li> <li>4. Read the received OAM messages and check whether the optical module status information mentioned in the table of Key Performance Indicators in section 6.1 of O-RAN.WG9.WDM-v01.00 is received, such as the wavelength, vender, ID, driving voltage, driving current, the launched optical power of the transmitter, the optical received power of the receiver, etc.</li> <li>5. For semi-active WDM type I systems and active WDM systems, configure the active WDM equipment at the O-DU side to send the optical module</li> </ol> | | | + +| | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | status inquiry and configuration requests to optical modules at the O-RU side, and check whether the corresponding responses are received. | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1. The active WDM equipment can get the correct information of optical module at O-RU side.</li> <li>2. For semi-active WDM type I system and active WDM system, the active WDM equipment can send inquiry and configuration messages to optical modules at the O-RU side and receive the corresponding response messages.</li> </ol> | +| <b>Test Output</b> | The OAM service layer function of active WDM equipment is OK, including inquiry, configuration and active. | +| | | + +| | | | | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------| +| <b>Test ID</b> | WDM.OAM.04 | <b>Classification</b> | Characterization | +| <b>Test Title</b> | OAM test for technical characteristics of multi-carrier OAM modulation | | | +| <b>Test Objective:</b> | To test the technical characteristics of multi-carrier OAM modulation | | | +| <b>Pre-Req</b> | | | | +| <b>Test Topology:</b> | <p>Applicable to O-RAN.WG9.WDM-v01.00, active WDM equipment for semi-active WDM system.</p> <p>Image: Test setup topology 1 diagram showing O-RU side and O-DU side components connected via fiber and optical modules.</p> <p>The diagram illustrates the test setup topology for OAM modulation. It is divided into two main sections: the O-RU side and the O-DU side. On the O-RU side, there is a 'Test board 1' containing multiple transceiver pairs (TRx 1, TRx 3, ..., TRx 2n-1). These are connected to a WDM module. A 50:50 optical splitter is used to split the signal, with one path going to a BER tester and the other to a VOA (Variable Optical Attenuator). The signal then travels through a 10km fiber to the O-DU side. On the O-DU side, the signal enters a 'Standard OAM demodulation equipment' block, which includes a demodulation module and a photodetector (PD). The output of the PD is split again, with one path going to a frequency spectrograph and the other to 'Test board 2'. Test board 2 contains multiple receiver/transmitter pairs (STRx 2, STRx 4, ..., STRx 2n). Both sides are connected to their respective testing management systems (system 1 on O-RU, system 2 on O-DU). The transmission is labeled as 10G/25G. Below the diagram, it specifies: 'Tx: 10G/25G @ λ2n-1, low speed OAM @ k2n-1' and 'Tx: 10G/25G @ λ2n, low speed OAM @ k2n'.</p> <p style="text-align: center;">Test setup topology 1</p> | | | + +![Test setup topology 2 diagram showing O-RU side and O-DU side connected via a 10km fiber link. The O-RU side includes Test board 1 with TRx 1, 3, ..., 2n-1, and a testing management system 1. The O-DU side includes Test board 2 with STRx 2, 4, ..., 2n, and a testing management system 2. A management system (MCU, PD, splitter) is connected to the O-DU side. A BER tester is connected to the O-RU side. The link consists of a 50:50 splitter, VOA, and 10km fiber. WDM components are used for multiplexing and demultiplexing.](0970dcee2196132ae81eb0bc460dfa9b_img.jpg) + +The diagram illustrates the test setup topology 2, showing the connection between the O-RU side and the O-DU side. On the O-RU side, Test board 1 contains multiple TRx modules (TRx 1, TRx 3, ..., TRx 2n-1) connected to a WDM component. A testing management system 1 is also connected to this side. On the O-DU side, Test board 2 contains multiple STRx modules (STRx 2, STRx 4, ..., STRx 2n) connected to a WDM component. A testing management system 2 is connected to this side. A management system (MCU, PD, splitter) is connected to the O-DU side. A BER tester is connected to the O-RU side. The link consists of a 50:50 splitter, VOA, and 10km fiber. WDM components are used for multiplexing and demultiplexing. The transmission is labeled as 10G/25G @ $\lambda_{2n-1}$ , low speed OAM @ $k_{2n-1}$ on the O-RU side and 10G/25G @ $\lambda_{2n}$ , low speed OAM @ $k_{2n}$ on the O-DU side. + +Test setup topology 2 diagram showing O-RU side and O-DU side connected via a 10km fiber link. The O-RU side includes Test board 1 with TRx 1, 3, ..., 2n-1, and a testing management system 1. The O-DU side includes Test board 2 with STRx 2, 4, ..., 2n, and a testing management system 2. A management system (MCU, PD, splitter) is connected to the O-DU side. A BER tester is connected to the O-RU side. The link consists of a 50:50 splitter, VOA, and 10km fiber. WDM components are used for multiplexing and demultiplexing. + +Test setup topology 2 + +An optical link consists of WDM components, like MUX/DEMUX and 10km optical fiber, which are used to connect optical modules at two ends to simulate the fronthaul optical transport channel. + +Colored optical modules are inserted on a test board like a transponder, on which a management system installs. The information of colored optical modules can be configured and read by the test boards through the management system. + +The standardized colored optical modules (STRxs) and standardized OAM demodulation equipment based on multi-carrier OAM modulation are used for the verification of the interoperation of optical module and active WDM equipment of different vendors. + +At the STRxs, the transmitting and receiving frequency of service signal is 10G or 25G, the carrier modulation frequencies of in-band OAM signals are unique for each WDM optical signals with different wavelengths ( $\lambda_2 \sim \lambda_{2n}$ ) and are between 1k to 100M. + +At the standardized OAM demodulation equipment, the optical signal with different wavelengths ( $\lambda_2 \sim \lambda_{2n}$ ) is converted into the electrical signal with different carrier modulation frequencies ( $k_1 \sim k_{2n-1}$ ) by a photoelectric detector (PD), and all in-band OAM messages with different carrier modulation frequencies ( $k_1 \sim k_{2n-1}$ ) can be demodulated together correctly from the electrical signal by a demodulation. + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Required tester</b> | General purpose bit error rate tester (BERT); frequency spectrograph; Optical power meter (OPM); variable optical attenuator (VOA); test board; | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>Connect the OPM, VOA, splitters, frequency spectrograph and BER tester to the reference points shown in the test setup topology 1.</li> <li>Configure the BERT to simulate service information transmission.</li> <li>Adjust the VOA to make the attenuation of the link meet the requirements of the power budget.</li> <li>Configure OAM connections between testing management systems and TRxs.</li> </ol> | +| <b>Procedure:</b> | <ol style="list-style-type: none"> <li>Check whether the service signal link communication between optical modules at different wavelength (<math>\lambda_1 \sim \lambda_{2n}</math>) are working correctly through the BERT.</li> <li>Check that the OAM data link communication of optical modules is OK through the testing management systems.</li> <li>Measure the carrier modulation frequencies (<math>k_1 \sim k_{2n}</math>) of in-band OAM signals at different wavelength channels through the frequency spectrograph, check</li> </ol> | + +| | | +|--|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>whether they are unique for each WDM optical signals with different wavelengths (<math>\lambda_1 \sim \lambda_{2n}</math>).</p> <p>4. Check whether the OAM messages from different OAM carriers are extracted correctly by the standardized OAM demodulation equipment.</p> <p>5. Connect the test setup as the test setup topology 2.</p> <p>6. Check whether the active WDM equipment could extract the OAM messages from different OAM carriers.</p> | +|--|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | +|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Pass/Fail Criteria:</b> | <p>the OAM data link communication of optical modules based on multi-carrier OAM modulation is OK.</p> <p>The carrier modulation frequencies (<math>k_1 \sim k_{2n}</math>) of in-band OAM signals are unique for each WDM optical signals with different wavelengths (<math>\lambda_1 \sim \lambda_{2n}</math>).</p> <p>The OAM messages from different OAM carriers are extracted correctly by the standardized OAM demodulation equipment.</p> <p>The active WDM equipment can receive the OAM messages from optical modules at O-RU side.</p> | +|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +| | | | | +|--------------------|------------------------------|---------------------------------|----------------------------------------| +| <b>Test Output</b> | optical module serial number | Optical transmission wavelength | low-speed carrier modulation frequency | +| | 1 | $\lambda_1$ | $k_1$ | +| | 2 | $\lambda_2$ | $k_2$ | +| | | | | +| | | | | +| | 2n | $\lambda_{2n}$ | $k_{2n}$ | + +| | | +|--|--| +| | | +|--|--| + +1 + +| | | | | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------| +| <b>Test ID</b> | WDM.OAM.05 | <b>Classification</b> | Characterization | +| <b>Test Title</b> | OAM test for the loopback configuration function of semi-active WDM system | | | +| <b>Test Objective:</b> | To test the loopback configuration function of semi-active WDM system | | | +| <b>Pre-Req</b> | | | | +| <b>Test Topology:</b> | <p>Applicable to O-RAN.WG9.WDM-v01.00, active WDM equipment for semi-active WDM system.</p> <img alt="Test Topology Diagram: O-RU side (O-RU, TRx 1, Tx, Rx, splitter, OPM, VOA) connected to WDM, then 10km fiber, then WDM, then O-DU side (Test board 2, STRx 2, Rx, Tx, BER tester, testing management system 2). A 10G/25G connection is shown between the O-DU side and the BER tester." data-bbox="539 1736 1300 2038" src="6b454ccf699bd029eab0e84d692716fe_img.jpg"/> | | | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p style="text-align: center;">Test setup topology 1</p> <img alt="Diagram of Test setup topology 1. On the O-RU side, a box labeled 'O-RU' contains 'TRx 1'. Its output goes to a 'splitter', which also feeds an 'OPM'. The main path goes through a 'VOA' and a 'WDM' component. This is connected via a '10km fiber' to another 'WDM' component on the O-DU side. The O-DU side contains an 'active WDM' box, which is connected to 'STRx 2'. A 'BER tester' is connected to the O-DU side at a '10G/25G' rate. A 'management system' is also connected to the O-DU side." data-bbox="526 291 1292 672" src="ec9b860f913e44cd061ba11e4b3e3c31_img.jpg"/> <p style="text-align: center;">Test setup topology 2</p> <p>An optical link consists of WDM components, like MUX/DEMUX and 10km optical fiber, which are used to connect optical modules at two ends to simulate the fronthaul optical transport channel.</p> <p>Optical modules are inserted on a test board like a transponder, on which a management system installs. The information of optical modules can be configured and read by the test boards through the management system.</p> <p>The standardized colored optical modules (STRx) are used for the verification of the optical module interoperation of different vendors.</p> <p>The STRxs can send the loopback configuration message and receive the response message of the loopback configuration success from the tested optical modules through the in-band OAM channel. The STRxs also can receive the loopback configuration message from the tested optical modules, configure itself on the loopback mode and send the response message of the loopback configuration success to the tested optical modules through the in-band OAM channel. If the response message of the loopback configuration success from the tested optical modules is received by STRxs, STRxs can send the 10G/25G PRBS test data stream and receive the 10G/25G data stream from the tested optical modules.</p> <p>It can be estimated by STRx whether there is a fault of the tested optical module:</p> <p>If the standardized response message of loopback configuration success isn't responded or the received 10G/25G data stream from the tested optical modules has error, the tested optical module is faulty.</p> <p>If standardized response message of the loopback configuration success is responded and the received 10G/25G data stream from the tested optical modules is error-free, the tested optical module is normal.</p> | +| <b>Required tester</b> | General purpose bit error rate tester (BERT); digital oscilloscope; Optical power meter (OPM); variable optical attenuator (VOA); test board; | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Connect the OPM, VOA, splitters and BER tester to the reference points shown in the test setup topology 1.</li> <li>2. Configure the BERT to simulate service information transmission.</li> <li>3. Adjust the VOA to make the attenuation of the link meet the requirements of the power budget.</li> <li>4. Configure OAM connections between testing management systems and TRxs.</li> </ol> | +| <b>Procedure:</b> | <ol style="list-style-type: none"> <li>1. Verify that the service channel isn't working through the BERT.</li> <li>2. Verify that the OAM data link communication of optical modules is OK.</li> </ol> | + +| | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | 3. Configure the STRxs to send the loopback configuration OAM message to optical module at the O-RU by the test management system 2.<br>4. Check whether the service channel is working properly through the BERT.<br>5. Check whether the standardized response OAM message from optical module at the O-RU could be extracted by the STRxs.<br>6. Connect the test setup as the test setup topology 2.<br>7. Configure the STRxs to send the loopback configuration OAM message to optical module at the O-RU by the active WDM equipment.<br>8. Check whether the service channel is working properly through the BERT.<br>9. Check whether the standardized response OAM message from optical module at the O-RU could be extracted by active WDM equipment. | +| <b>Pass/Fail Criteria:</b> | <p>If the service channel is working properly through the BERT and the standardized response OAM message could be extracted, the optical module satisfies the loopback configuration requirement.</p> <p>If the service channel is working properly through the BERT and the standardized response OAM message could be extracted by the active WDM equipment, the active WDM equipment satisfies the loopback configuration requirement.</p> | +| <b>Test Output</b> | The loopback configuration function of semi-active WDM system is OK. | +| | | + +### 7.1.7 Management Interface Test + +Functional requirements for Semi-active Front-haul WDM systems have been defined in the current version of Management Interfaces for Transport Network Elements (O-RAN.WG9.XTRP-MGT.0-v04.0). The centralized management system could send management requests to the active WDM equipment and control the semi-active WDM front-haul systems of multiple vendors through the unified Netconf interface. To fully verify the functional requirements of the management system and interface, typical test cases shall be included. + +| | | | | +|------------------------|-------------------------------------------------------------------------------------------------------|-----------------------|---------------------------------| +| <b>Test ID</b> | WDM.management.01 | <b>Classification</b> | Management System Functionality | +| <b>Test Title</b> | Network element information query | | | +| <b>Test Objective:</b> | To test if the WDM management southbound interface support network element information query function | | | +| <b>Test Topology:</b> | Refer to O-RAN.WG9.WDM-v01.00, Section 2.3 Semi-Active WDM system | | | + +| | | | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--|--| +| | <p><b>test topology</b></p> <img alt="Test topology diagram showing the connection between the O-RU side and the O-DU side. On the O-RU side, there is an 'Optical module under test' within an 'OAM system' (indicated by a dashed box). This is connected to an 'OM/OD' component. On the O-DU side, there is 'Open-WDM equipment'. A bidirectional arrow labeled 'Netconf' connects the 'Management system' to the 'Open-WDM equipment'. Another bidirectional arrow connects the 'OM/OD' component to the 'Open-WDM equipment'." data-bbox="443 241 1161 683" src="0d30ac15d614bcd275c2e60ae11cea65_img.jpg"/> <p>O-RU side                      O-DU side</p> | | | +| <b>Required tester</b> | Southbound interface test tool | | | +| <b>Pre-Req</b> | 1. Connect the test topology according to the test configuration; | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p>2. Query the network element information through the ‘get’ command on the management and control system. Verify that some typical network element information can be obtained.</p> <p>3. Verify whether the queried information is consistent with the actual situation of the device.</p> <p><b><u>Verifications needed:</u></b></p> <p>2. Record the actual situation of the device.</p> | | | +| <b>Pass/Fail Criteria:</b> | 1. Step 2 can query the device network element information, and the information is consistent with the actual situation of the device. | | | +| <b>Test Output</b> | <p>Typical network element information:</p> <p>a) Network element information list;    b) Network element ID;</p> <p>c) Network element name;                  d) The manufacturer name of the network element;</p> <p>e) Product name;                              f) Software version;</p> <p>g) Additional attributes;                    h) Network element classification: semi-active, etc.;</p> <p>i) Hardware version;                          j) Network element IP;</p> <p>k) Board list;                                    l) Layer protocol;</p> <p>m) Gateway.</p> | | | + +1 + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------|-----------------------|---------------------------------| +| <b>Test ID</b> | WDM.management.02 | <b>Classification</b> | Management System Functionality | +| <b>Test Title</b> | Loopback configuration and query | | | +| <b>Test Objective:</b> | To test if the WDM management southbound interface support loopback configuration and query function | | | +| <b>Test Topology:</b> | Refer to O-RAN.WG9.WDM-v01.00, Section 2.3 Semi-Active WDM system | | | + +| | | +|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p style="text-align: center;"><b>test topology</b></p> <img alt="Test topology diagram showing the connection between the O-RU side and the O-DU side. On the O-RU side, there is an 'Optical module under test' within an 'OAM system' box. A 'LOOPBACK' is indicated on a 'Port' of this module. This is connected to an 'OM/OD' block. On the O-DU side, there is 'Open-WDM equipment'. A bidirectional arrow connects the 'OM/OD' block to the 'Open-WDM equipment'. Above the 'Open-WDM equipment' is a 'Management system' box, connected to it via a 'Netconf' interface." data-bbox="435 241 1326 680" src="b4cd7dd6811aa60c4ebd5932f18b43c9_img.jpg"/> <p style="text-align: center;">O-RU side                      O-DU side</p> | +| <b>Required tester</b> | Southbound interface test tool | +| <b>Pre-Req</b> | 1. Connect the test topology according to the test configuration; | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>2. Loopback setting and query: <ol style="list-style-type: none"> <li>a) Query the WDM device port information on the management and control system.</li> <li>b) Use the '<i>edit-config</i>' command to configure several ports loopback into the following types respectively, and verify that the loopback setting is successful: <ul style="list-style-type: none"> <li>– FACILITY_LOOPBACK</li> <li>– TERMINAL_LOOPBACK</li> <li>– NON_LOOPBACK</li> </ul> </li> </ol> </li> <li>3. Use the '<i>get</i>' command on the management system to query the loopback types of all the network element ports and the loopback type of the specified port, and verify that the query is successful.</li> </ol> | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1. The loopback configuration should be able to return the operation result (success/failure).</li> <li>2. The loopback query results in step 3 should be consistent with the actual configuration in step 2.</li> <li>3. Supports two query granularities: network element and port.</li> </ol> | +| <b>Test Output</b> | <ol style="list-style-type: none"> <li>1. The loopback query result must include the port loopback status;</li> <li>2. The query result value without loopback type is empty.</li> </ol> | + +1 + +### 7.1.8 Performance of a pair of MUX/DEMUXs + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | WDM.MUX-DEMUX | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Performance of a pair of MUX/DEMUXs | | | +| <b>Test Objective:</b> | The aim of the test is to measure the performance of a pair of MUX/DEMUXs, including the max shift of central wavelength, max 1 dB bandwidth and insertion loss of a pair of MUX/DeMUXs. | | | +| <b>Pre-Req</b> | Connect the test topology according to the test configuration | | | + +| <b>Test Topology:</b> | <p>Applicable to O-RAN.WG9.WDM-v01.00, Passive, Semi-Active, and Active WDM fronthaul system</p> <img alt="Test Topology Diagram: A block diagram showing a testing controller connected to a Tunable laser and a Power meter. The Tunable laser is connected to the left input of a WDM (Wavelength Division Multiplexer) block. The Power meter is connected to the right output of a WDM (Wavelength Division Demultiplexer) block. The two WDM blocks are connected to each other." data-bbox="459 353 1396 795" src="988a0c7087d0989cf2a0bb2ed500b9d0_img.jpg"/> | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +|-------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------|------|-----------------|--------|--------|--------|--------|--------|--------|--------|--------|--------|--------|--------|--------------------|----|--------|--------|--------|--------|--------|--------|--------|--------|--------|--------|--------|--------|---------------------------------|----|-----------|--|--|--|--|--|--|--|--|--|--|--|----------------|----|------------|--|--|--|--|--|--|--|--|--|--|--|-------------------------------------------------------------------------------|----|-----|-----|-----|-----|-----|-----|-----|-----|-----|-----|-----|-----| +| <b>Required tester</b> | Tunable Laser, Power meter | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Connect the tunable Laser and power meter directly, and measure and store the output power curves '<math>P_{btb}(\lambda)</math>'(dBm) as the reference while the tunable laser wavelength is swept within the wavelength range of WDM system requirement.</li> <li>2. Connect the tunable Laser and power meter to the reference points shown in the above test configuration.</li> </ol> | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| <b>Procedure:</b> | <ol style="list-style-type: none"> <li>3. Detailed Test procedure:</li> <li>4. The tunable laser is connected to the left port '<math>i</math>' (<math>i=1,\dots,n</math>), and the power meter is connected to the right port '<math>i</math>' (<math>i=1,\dots,n</math>) of the paired device;</li> <li>5. The wavelength of the tunable laser is swept within the working wavelength range and the power curve '<math>P_i(\lambda)</math>'(dBm) is measured and stored;</li> <li>6. The Transmission power spectrum curve '<math>T_i(\lambda)</math>' of pair of MUX/DEMUXs is got by the formula: <math>T_i(\lambda)=P_{btb}(\lambda)-P_i(\lambda)</math>;</li> <li>7. 1 dB bandwidth of wavelength channel '<math>i</math>': Find the wavelength bandwidth that the difference between '<math>T_i(\lambda)</math>' and max value of '<math>T_i(\lambda)</math>' is no more than 1dB;</li> <li>8. Insertion loss of a pair of MUX/DeMUXs of wavelength channel '<math>i</math>': find the min value of '<math>T_i(\lambda)</math>' at 1 dB wavelength bandwidth;</li> <li>9. Shift of central wavelength of wavelength channel '<math>i</math>': the difference between the central wavelength of 1 dB bandwidth wavelength range and the standardized central wavelength.</li> </ol> | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| <b>Pass/Fail Criteria:</b> | <p>If the value of performance is in the standardized range, pass; <span style="color: blue;">if not</span>, fail.</p> <table border="1"> <thead> <tr> <th rowspan="2">Parameters</th> <th rowspan="2">Unit</th> <th colspan="12">Proposed values</th> </tr> </thead> <tbody> <tr> <td>Central wavelength</td> <td>nm</td> <td>1267.5</td> <td>1274.5</td> <td>1287.5</td> <td>1294.5</td> <td>1307.5</td> <td>1314.5</td> <td>1327.5</td> <td>1334.5</td> <td>1347.5</td> <td>1354.5</td> <td>1367.5</td> <td>1374.5</td> </tr> <tr> <td>Max shift of central wavelength</td> <td>nm</td> <td colspan="12"><math>\pm 1.2</math></td> </tr> <tr> <td>1 dB bandwidth</td> <td>nm</td> <td colspan="12"><math>\geq 5.0</math></td> </tr> <tr> <td>Max Insertion loss @ O-RU+O-DU pairs, including the IL of an optical splitter</td> <td>dB</td> <td>6.1</td> <td>6.1</td> <td>6.1</td> <td>6.1</td> <td>6.1</td> <td>6.1</td> <td>4.5</td> <td>4.5</td> <td>3.0</td> <td>3.0</td> <td>3.0</td> <td>3.0</td> </tr> </tbody> </table> | Parameters | Unit | Proposed values | | | | | | | | | | | | Central wavelength | nm | 1267.5 | 1274.5 | 1287.5 | 1294.5 | 1307.5 | 1314.5 | 1327.5 | 1334.5 | 1347.5 | 1354.5 | 1367.5 | 1374.5 | Max shift of central wavelength | nm | $\pm 1.2$ | | | | | | | | | | | | 1 dB bandwidth | nm | $\geq 5.0$ | | | | | | | | | | | | Max Insertion loss @ O-RU+O-DU pairs, including the IL of an optical splitter | dB | 6.1 | 6.1 | 6.1 | 6.1 | 6.1 | 6.1 | 4.5 | 4.5 | 3.0 | 3.0 | 3.0 | 3.0 | +| Parameters | Unit | | | Proposed values | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| | | Central wavelength | nm | 1267.5 | 1274.5 | 1287.5 | 1294.5 | 1307.5 | 1314.5 | 1327.5 | 1334.5 | 1347.5 | 1354.5 | 1367.5 | 1374.5 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| Max shift of central wavelength | nm | $\pm 1.2$ | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| 1 dB bandwidth | nm | $\geq 5.0$ | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| Max Insertion loss @ O-RU+O-DU pairs, including the IL of an optical splitter | dB | 6.1 | 6.1 | 6.1 | 6.1 | 6.1 | 6.1 | 4.5 | 4.5 | 3.0 | 3.0 | 3.0 | 3.0 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | + +| | | +|-------------|--| +| Test Output | | +|-------------|--| + +1 + +### 7.1.9 Protection function for WDM system + +| Test ID | WDM.protection | Classification | Functionality | +|---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | protection function for WDM system | | | +| Test Objective: | The aim of the test is to check protection function for WDM system defined in “WDM-based Fronthaul Transport” | | | +| Pre-Req | Running service will be interrupted | | | +| Test Topology: | <p>Applicable to O-RAN.WG9.WDM-v01.00, Semi-Active and Active WDM fronthaul system</p> <img alt="Test Topology Diagram: A schematic showing the protection function for a WDM system. It includes an O-RU side with TRx 1 and Rx Tx, connected to an active/passive WDM. This is connected to a Host, which is connected to an active WDM on the O-DU side. The Host is also connected to a Backup path. A BER tester is connected to the Host and the active WDM. A management system is connected to the Host and the active WDM. The O-DU side also includes Rx Tx and TRx 4." data-bbox="411 750 1332 1108" src="d1af0de88faa3c4d9f3152f936cba8ab_img.jpg"/> | | | +| Required tester | bit error rate tester (BERT) | | | +| Test Configuration | <ol style="list-style-type: none"> <li>1 . Connect the BER tester to the reference points shown in the above test configuration.</li> <li>2. Configure the BER tester to simulate service information transmission.</li> </ol> | | | +| Procedure: | <ol style="list-style-type: none"> <li>1. On the management and control system, create or modify protection function through “edit-config” command.</li> <li>2. On the management and control system, execute protection switching through RPC commands, and the commands include the following input content: <ol style="list-style-type: none"> <li>a) Protection ID</li> <li>b) Switching command, such as manual switching, forced switching,</li> <li>c) protection Direction, such as Host and Backup</li> </ol> </li> <li>3. Check the service connection status through the data network analyzer and record the service protection switching downtime.</li> <li>4. On the management and control system, query the protection information through “get-config” command to verify whether the switching has been successful.</li> <li>5. Create a link break fault and repeat step 3 and 4.</li> </ol> | | | +| Pass/Fail Criteria: | <p>Verify whether protection functions can be queried and configured through management system for active and semi-active WDM system.</p> <p>Verify whether the performance of the protection function meets the requirements.</p> | | | +| Test Output | <p>Protection functions can be queried and configured through management system for active and semi-active WDM system.</p> <p>The performance of the protection function meets the requirements.</p> | | | + +2 + + + +# 8 Packet-Switched Architectures and Solutions Testing + +This chapter is composed of four sections: + +- Generalized basic verification test. +- Service level tests +- Network element test +- Additional network tests + +The first section covers the most common and basic packet tests of an Xhaul network (from a UNI interface to another UNI interface). The second section delivers test cases for service level testing at UNI interfaces. + +The third section is limited to testing the functions of a packet-switched Transport Network Element (TNE). + +The last section provides other test cases outside of the above the three categories. + +## 8.1 Generalized basic verification methods for Xhaul Transport packet switched Network. + +This section covers the most common and basic verification methods using Traffic Generator and Analyzer tool. + +Table 8.1-1 summarizes the encapsulation of traffic streams combination of which shall be used in generalized verification methods that must be executed to validate any transport network. + +| Transport Network Type | Traffic stream | Packet Encapsulation | VLAN PCP bits | DSCP bits | Frame Size (min, max) | +|------------------------|-----------------------------------------------------|-------------------------------------------------|---------------|-----------|-----------------------| +| Fronthaul | Split option 7-2x eCPRI U-plane and C-plane traffic | Option 1 –Ethernet + eCPRI | | | As per network | +| | | Option 2 – Ethernet + VLAN + eCPRI | 7 (default) | | As per network | +| | | Option 3 – Ethernet + IPv4 + UDP + eCPRI | | EF | As per network | +| | | Option 4 - Ethernet + VLAN + IPv4 + UDP + eCPRI | 7 (default) | EF | As per network | +| | | Option 5 – Ethernet + IPv6 + UDP + eCPRI | | EF | As per network | +| | | Option 6 - Ethernet + VLAN + IPv6 + UDP + eCPRI | 7 (default) | EF | As per network | +| | M-plane Traffic | Option 1 –Ethernet + IPv4 + Netconf | | AF2x | As per network | +| | | Option 2 – Ethernet + VLAN + IPv4 + Netconf | 2 (default) | AF2x | As per network | +| | | Option 3 – Ethernet + IPv6 + Netconf | | AF2x | As per network | +| | | Option 4 - Ethernet + VLAN + IPv6 + Netconf | 2 (default) | AF2x | As per network | +| | RoE Traffic | Option 1 - Ethernet + RoE | | | As per network | + +| | | | | | | +|----------|--------------------------------------|-----------------------------------|----------------------------------|----------------------------------|----------------| +| | | Option 2 - Ethernet + VLAN + RoE | 7 (default) | | As per network | +| Midhaul | User plane and control plane traffic | Option 1 – Ethernet + IPv4 | | As per QoS scheme of the network | As per network | +| | | Option 2 – Ethernet + VLAN + IPv4 | As per QoS scheme of the network | As per QoS scheme of the network | As per network | +| | | Option 3 – Ethernet + IPv6 | | As per QoS scheme of the network | As per network | +| | | Option 4 – Ethernet + VLAN + IPv6 | As per QoS scheme of the network | As per QoS scheme of the network | As per network | +| | M-plane traffic | Option 1 – Ethernet + IPv4 | | As per QoS scheme of the network | As per network | +| | | Option 2 – Ethernet + VLAN + IPv4 | As per QoS scheme of the network | As per QoS scheme of the network | As per network | +| | | Option 3 – Ethernet + IPv6 | | As per QoS scheme of the network | As per network | +| | | Option 4 – Ethernet + VLAN + IPv6 | As per QoS scheme of the network | As per QoS scheme of the network | As per network | +| Backhaul | User plane and control plane traffic | Option 1 – Ethernet + IPv4 | | As per QoS scheme of the network | As per network | +| | | Option 2 – Ethernet + VLAN + IPv4 | As per QoS scheme of the network | As per QoS scheme of the network | As per network | +| | | Option 3 – Ethernet + IPv6 | | As per QoS scheme of the network | As per network | +| | | Option 4 – Ethernet + VLAN + IPv6 | As per QoS scheme of the network | As per QoS scheme of the network | As per network | +| | M-plane traffic | Option 1 – Ethernet + IPv4 | | As per QoS scheme of the network | As per network | +| | | Option 2 – Ethernet + VLAN + IPv4 | As per QoS scheme of the network | As per QoS scheme of the network | As per network | +| | | Option 3 – Ethernet + IPv6 | | As per QoS scheme of the network | As per network | +| | | Option 4 – Ethernet + VLAN + IPv6 | As per QoS scheme of the network | As per QoS scheme of the network | As per network | + +**Table 8.1-1** + +Peak fronthaul bandwidth required for 7-2x split based eCPRI traffic can be estimated by the following formula as specified in section 7.2 of Xhaul Transport Requirements doc. + +$$FH \text{ BW} = 2 \times 10^{-9} (1 + c) \frac{v_{layer} N_{PRB} (12 N_{mantissa} + N_{exponent})}{T_s^\mu} \text{ (Gbps)}$$ + +$v_{layer}$ is the maximum number of supported layers. + +$N_{PRB}$ is the maximum RB allocation for a given channel bandwidth and numerology $\mu$ + +$N_{mantissa}$ is the number of mantissa bits. + +$N_{exponent}$ is the number of the exponent bits. + +$T_s^\mu$ is the average OFDM symbol duration in a subframe for numerology, i.e., $T_s^\mu = \frac{10^{-3}}{14 \times 2^\mu}$ + +$c$ is C-plane overhead. For downlink $c \approx 10\%$ and for uplink $c \approx 0$ + +Table 8.1-2 provides some examples for peak fronthaul bandwidth calculated for different scenarios assuming $N_{mantissa} = 9$ and $N_{exponent} = 4$ + +| Number of Sectors | CBW (MHz) | $\mu$ | MIMO Layers | ABW (MHz) | FH BW (Gbps) | +|-------------------|-----------|-------|-------------|-----------|--------------| +| 1 | 100 | 1 | 4 | 400 | 7.7 | +| 1 | 400 | 3 | 2 | 800 | 14.57 | + +**Table 8.1-2** + +The above estimate does not include protocol encapsulation overhead which should be added based upon encapsulation type and average packet size. + +Table 8.1-3 provides traffic profiles to be used to simulate eCPRI traffic for Fronthaul network testing + +| Traffic Profile | Packet Encapsulation and QoS marking | Stream Pattern | Stream Property | Traffic Load percentage | +|----------------------------|--------------------------------------|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------| +| FH eCPRI traffic profile 1 | As per Table 8.1-1 | Constant Bit Rate | Frame size = maximum allowed frame size<br>Frame rate = as calculated using the formula for peak fronthaul bandwidth * traffic load percentage | 20%,50%,100% | +| FH eCPRI traffic profile 2 | As per Table 8.1-1 | Constant Bit Rate | Frame size = minimum allowed frame size<br>Frame rate = as calculated using the formula for peak fronthaul bandwidth * traffic load percentage | 20%,50%,100% | + +| | | | | | +|----------------------------|--------------------|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------| +| FH eCPRI traffic profile 3 | As per Table 8.1-1 | Constant Bit Rate | Frame size = Random or any other distribution such as custom, IMIX, Gaussian etc.<br>Frame rate = as calculated using the formula for peak fronthaul bandwidth * traffic load percentage | 20%,50%,100% | +| FH eCPRI traffic profile 4 | As per Table 8.1-1 | Burst | Frame size = maximum allowed frame size<br>Gap between two consecutive bursts = 1 ms or less<br>Frame Count in burst is such that average frame rate $\approx$ calculated peak fronthaul bandwidth * traffic load percentage | 20%,50%,100% | +| FH eCPRI traffic profile 5 | As per Table 8.1-1 | Burst | Frame size = minimum allowed frame size<br>Gap between two consecutive bursts = 1 ms or less<br>Frame Count in burst is such that average frame rate $\approx$ calculated peak fronthaul bandwidth * traffic load percentage | 20%,50%,100% | + +**Table 8.1-3** + +Table 8.1-4 provides traffic profiles to be used to simulate M-plane and background traffic for Fronthaul network testing. It has been assumed that M-plane traffic would be bursty in nature and may occupy the rest of the available bandwidth after bandwidth utilization by eCPRI traffic. + +| Traffic Profile | Packet Encapsulation and QoS marking | Stream Pattern | Stream Property | +|------------------------------|--------------------------------------|----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| FH M-plane traffic profile 1 | As per Table 8.1-1 | Burst | Frame size = maximum allowed frame size<br>Gap between two consecutive bursts = 1 ms or less<br>Frame Count in burst is such that average frame rate $\approx$ interface rate - calculated peak fronthaul bandwidth | +| FH M-plane traffic profile 2 | As per Table 8.1-1 | Burst | Frame size = minimum allowed frame size<br>Gap between two consecutive bursts = 1 ms or less<br>Frame Count in burst is such that average frame rate $\approx$ interface rate - calculated peak fronthaul bandwidth | + +**Table 8.1-4** + +Figure 8.1-1 depicts a generic test set up for network under test with Traffic Generator and Analyzer tool. + +![Diagram of a generic test setup for a network under test. A cloud labeled 'Xhaul Transport Network' is connected via two or more Ethernet ports to a box labeled 'Traffic Generator and Analyzer'. The connection is labeled 'connected to UNIs of network.'.](3261ca490d9efeff7ce47e69b30a181e_img.jpg) + +``` + +graph TD + Xhaul((Xhaul Transport Network)) + subgraph Tools [Traffic Generator and Analyzer] + direction TB + TGA[Traffic Generator and Analyzer] + end + Xhaul ---|Two or more Ethernet ports connected to UNIs of network| TGA + +``` + +Diagram of a generic test setup for a network under test. A cloud labeled 'Xhaul Transport Network' is connected via two or more Ethernet ports to a box labeled 'Traffic Generator and Analyzer'. The connection is labeled 'connected to UNIs of network.'. + +**Figure 8.1-1** + +### 8.1.1 Forwarding Verification + +Once the required combination of traffic streams is set up in Traffic Generator and Analyzer Tool with desired scale of source and destination endpoints in transport layer (for example thousands of Ethernet/IPv4/IPv6 endpoints), steps from table 8.1.1-1 shall be executed. Since this step is to just ensure basic forwarding capability, the configured rate of the traffic streams could be low. + +| Test Steps | Expected result | +|---------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------| +| Send traffic streams with minimum and maximum frame size and verify that no frames are dropped from the counters of Traffic Generator and Analyzer tool | No frames shall be dropped by network | + +**Table 8.1.1-1** + +### 8.1.2 Latency Measurement and Verification + +Depending upon network type and application type, latency requirement could be different in network. For fronthaul network, maximum tolerable latency for different use cases is described in Table 3 of Xhaul Transport Requirements document. For midhaul and backhaul networks latency limits are described in Table 5 and Table 6 of the same document respectively. + +Latency in packet switched network can be measured in four different ways – + +3. Store and Forward Latency (The time interval starting when the last bit of the frames leaves sending port and ending when the first bit of the frame is seen on the receiving port or LIFO) +4. Cut Through Latency (The time interval starting when the first bit of the frames leaves sending port and ending when the first bit of the frame is seen on the receiving port or FIFO) +5. MEF Frame Delay (The time interval starting when the first bit of the frames leaves sending port and ending when the last bit of the frame is seen on the receiving port or as FILO) +6. Forwarding Delay (The time interval starting when the last bit of the frames leaves sending port and ending when the last bit of the frame is seen on the receiving port or as LILO) + +Anyone of the four methods could be used. However, the last method is recommended as it captures the delay caused by only the network under test. + +Step from table 8.1.2-1 below shall be executed for measuring latency + +| Test Steps | Expected result | +|--------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| +| While executing step from Table 8.1.1-1, measure the latency for both minimum and maximum sized frames | Measured latency of individual traffic streams shall not be more than applicable latency limit depending upon the targeted use cases and network type. | + +**Table 8.1.2-1** + +### 8.1.3 RFC 2544 Benchmarking test for frame loss rate, latency, throughput + +Once results from 8.1.1 and 8.1.2 are satisfactory, RFC 2544 benchmarking tests shall be executed for frame loss, latency, and throughput as mentioned in table 8.1.3-1. + +| Test Steps | Expected result | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------| +| <u>RFC 2544 frame loss test</u><br>Execute RFC 2544 frame loss test starting with 100% interface speed and different frame size (as an example 70, 100, 250, 300, 400, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300, 1400, 1500, 1522 bytes or up to size of jumbo frames if they are supported) for each class of traffic stream identified. Test duration for each iteration should be 120 seconds minimum. Observe the maximum rate achieved for each class of stream without any frame loss. | Maximum rate achieved for each class of traffic stream shall be equal to more than the demand of respective application. | + +| | | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------| +| <u>RFC 2544 latency test</u><br>Execute RFC 2544 latency test with maximum rate achieved in previous step without any frame loss and different frame size (as an example 70, 100, 250, 300, 400, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300, 1400, 1500, 1522 bytes) for each class of traffic stream identified. Test duration for each iteration should be 120 seconds minimum. Observe the minimum, maximum, average latency, and delay variation for each class of stream without any frame loss. | Maximum latency measured for each traffic stream shall be within tolerable latency limit of respective application. | +| <u>RFC 2544 throughput test</u><br>While executing previous step also measure the throughput achieved without any loss | Throughput achieved without any loss and within tolerable latency limit shall meet the application demand. | + +**Table 8.1.3-1** + +## 8.2 Service Level Test Cases + +This section covers the baseline test case scenarios to be validated for service and underlying transport network setup. These scenarios utilize general basic verification mentioned in Section 8.1 and can also be used in various other Network Testing use cases mentioned in section 8.4. + +Although the test cases and their respective topologies shown in this section shows a single interface simulating the O-RU and O-DU connecting to the CSR and HSR, it is recommended that basic functionality for Fronthaul scenarios involving multiple O-RU's connected to the CSR should also be verified as part of these test cases. This verification will help in ensuring real-life deployments, where a lot of time multiple O-RU's (or its simulated interfaces) are connected to the same CSR are covered. Some of these "typical" scenarios are covered in WG9 - Xhaul Transport Requirements specification, specifically Table 4. A sample scenario with 1 and 3 O-RU's, each representing a sector, along with the bandwidth requirements for FH is shown below. Please note that this is just an example and actual test and deployment scenario may vary, some of which are documented in the Xhaul Transport Requirements specification + +| Cell Size | Sectors | Total CBW (MHz) | MIMO Layers | ABW (MHz) | FH BW (Gbps) | +|-----------|---------|-----------------|-------------|-----------|--------------| +| Small | 1 | | - | | | +| Medium | 3 | 100 | 4 | 1200 | 23 | +| Large | 3 | 100 | 16 | 4800 | 90 | + +**Table 8.2-1** + +It is also recommended to use "background traffic" alongside the Split 7-2x eCPRI traffic on the CSR and HSR as well. Another interface for this background traffic will be used from test equipment to the O-RU and O-DU. This ethernet interface will carry "other" traffic such as Wireline or Enterprise traffic, primarily in the + +form on MPLS L3VPN. Each of the testcases in this section reflect the topology with additional interface for background traffic. + +In the following test cases a Traffic Gen (also referred to as an O-DU or O-RU simulator) is used to generate and analyze test traffic towards O-RU or O-DU. It is connected directly to a CSR or an HSR port that usually connects to an O-RU or an O-DU. For illustration purposes the O-RU or O-DU are left in the test setup diagrams, although they are not needed for the test application. + +### 8.2.1 Baseline 7-2x eCPRI transport over Packetized Fronthaul + +| Test ID | Ethernet.FH.01 | Classification | Fronthaul Services | +|--------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|--------------------| +| Test Title | Baseline 7-2x eCPRI transport over Packetized Fronthaul | | | +| Test Objective: | 1. Verify O-RU – O-DU communication over packetized Fronthaul network using SR-MPLS and/or SRv6 based transport | | | +| Pre-Req | SR-MPLS and/or SRv6 baseline configuration on CSR, HSR and any other Fronthaul routers<br><br>Optional Timing and syn configuration through FH network for RAN Nodes if actual O-RU and O-DU are used instead of O-RU and O-DU simulators | | | +| Test Topology: | <img alt="Test Topology Diagram: A network diagram showing O-RU connected to CSR via 7.2x eCPRI. CSR is connected to HSR1 via a packetized fronthaul network (indicated by a red cloud). HSR1 is connected to O-DU via 7.2x eCPRI. A Traffic Gen block is connected to both CSR and HSR1." data-bbox="414 1115 1145 1294" src="f6af9077a2a151d8ee733f47d57b5d1f_img.jpg"/> | | | +| Test Configuration | <ol style="list-style-type: none"> <li>1. Connect O-RU or O-RU simulator to the UNI of the CSR and O-DU or O-DU simulator to the HSR.</li> <li>2. Although not required for this baseline test, 1 or more routers should be used in the Fronthaul test network for future test cases (SRTE, Redundancy, etc)</li> <li>3. Configure L2 transport service between CSR and HSR from O-RU Uni to O-DU Uni using L2 VPN or EVPN VPWS or both</li> <li>4. Connect a tester to O-RU and O-DU to send simulated UE traffic</li> <li>5. If actual O-RU and O-DU are used, connect a tester to O-RU and O-DU to send simulated UE traffic. If not, send eCPRI 7-2x traffic directly from simulators.</li> </ol> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Verify O-RU and O-DU are up and communicating if actual O-RU and O-DU are used instead of simulators.</li> <li>2. Start bi-directional eCPRI traffic through CSR and HSR between the RAN node, or their simulators, verify traffic is being received on either ends.</li> <li>3. Simultaneously send background L3VPN traffic using the additional ethernet interface on CSR and HSR. Ensure that combined eCPRI and L3VPN traffic do not exceed CSR and HSR's uplink capacity.</li> <li>4. Execute Test cases documented in Sections 8.1 and 8.4 using both SR-MPLS and/or SRv6 based transport</li> </ol> | | | + +| | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>100% successful 7-2x eCPRI traffic transport between O-RU and O-DU, or their simulators</li> <li>100% successful background L3VPN traffic transport through the packetized Fronthaul</li> <li>Verify traffic stats on: <ol style="list-style-type: none"> <li>Test equipment</li> <li>O-RU and O-DU, if possible</li> <li>CSR and HSR interface and L2VPN/EVPN VPWS service counters</li> </ol> </li> <li>The test topology and setup could be used for more granular test cases and measurements (various traffic mix, Latency, etc) documented in Section 8.4</li> </ol> | +| <b>Test Output</b> | <p>Capture configuration used for reference.</p> <p>Capture verification commands (show commands) as appropriate.</p> | + +### 8.2.2 Constraints based 7-2x eCPRI transport over Packetized Fronthaul using Headend Path calculation + +| | | | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------| +| <b>Test ID</b> | Ethernet.FH.02 | <b>Classification</b> | Fronthaul Services | +| <b>Test Title</b> | Constraints based 7-2x eCPRI transport over Packetized Fronthaul using Headend Path calculation | | | +| <b>Test Objective:</b> | 1. Verify O-RU – O-DU communication over packetized Fronthaul network using SR-MPLS and/or SRv6 based transport | | | +| <b>Pre-Req</b> | SR-MPLS and/or SRv6 baseline configuration on CSR, HSR and any other Fronthaul routers<br><br>Optional Timing and syn configuration through FH network for RAN Nodes, if actual O-RU and O-DU are used instead of O-RU and O-DU simulators | | | +| <b>Test Topology:</b> | Same as described in Ethernet.FH.01 | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>Connect O-RU or the O-RU simulator to the UNI of the CSR, and O-DU or O-DU simulator to the HSR.</li> <li>1 or more routers should be used in the Fronthaul test network to ensure constrains based path calculation.</li> <li>Configure L2 transport service between CSR and HSR from O-RU Uni to O-DU Uni using L2 VPN or EVPN VPWS or both</li> <li>Connect an additional interface from traffic generator to the CSR and the HSR to carry the background L3VPN traffic. The CSR and HSR should be pre-configured with L3VPN services to carry this background traffic.</li> <li>If actual O-RU and O-DU are used, connect a tester to O-RU and O-DU to send simulated UE traffic. If not, send eCPRI 7-2x traffic directly from simulators.</li> </ol> | | | +| <b>Procedure:</b> | <b><u>Detailed Test procedure:</u></b> <ol style="list-style-type: none"> <li>Verify O-RU and O-DU are up and communicating if actual O-RU and O-DU are used instead of simulators.</li> </ol> | | | + +| | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>Start bi-directional eCPRI traffic through CSR and HSR between the RAN nodes, or their simulators</li> <li>Verify traffic is being received on either ends using shortest IGP path between CSR and HSR.</li> <li>Simultaneously send background L3VPN traffic using the additional ethernet interface on CSR and HSR. Ensure that combined eCPRI and L3VPN traffic do not exceed CSR and HSR's uplink capacity.</li> <li>Configure an SRTE policy defining a constrain based path, different than the IGP shortest path. SRTE policy should use Headend (CSR or HSR) based path calculation.</li> <li>Constraints may include: <ol style="list-style-type: none"> <li>Include or exclude certain links.</li> <li>Lowest latency path (latency may be increased on the IGP shortest path to force a longer IGP path but with lower latency)</li> <li>Use of Flex-Algo to enforce path selection.</li> </ol> </li> <li>Apply the policy to the L2VPN/EVPN VPWS service as well as L3VPN services using static configuration or route-coloring.</li> <li>Execute Test cases documented in Sections 8.1 and 8.4 using both SR-MPLS and/or SRv6 based transport</li> </ol> | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>Verify traffic used IGP best path before applying SRTE Policy.</li> <li>Verify route coloring and the use of SRTE policy for EVPN VPWS and L3VPN service between HSR and CSR once SRTE is configured.</li> <li>Verify traffic used updated path based on constraints defined by SRTE policy.</li> <li>Verify SID path list accurately reflects the path used by EVPN VPWS and L3VPN background traffic.</li> <li>Ensure 100% traffic send/received success.</li> <li>The test topology and setup could be used for more granular test cases and measurements (various traffic mix, Latency, etc) documented in 8. and 8.4.</li> </ol> | +| <b>Test Output</b> | <p>Capture configuration used for reference.</p> <p>Capture verification commands (show commands) as appropriate for:</p> <ol style="list-style-type: none"> <li>Route coloring and SRTE policy use with EVPN VPWS and L3VPN.</li> <li>SID list/SRTE Path calculation performed by headend</li> </ol> | + +### 8.2.3 Constraints based 7-2x eCPRI transport over Packetized Fronthaul using Controller based Path calculation. + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------| +| <b>Test ID</b> | Ethernet.FH.03 | <b>Classification</b> | Fronthaul Services | +| <b>Test Title</b> | Constraints based 7-2x eCPRI transport over Packetized Fronthaul using Controller based Path calculation | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>Verify O-RU – O-DU communication over packetized Fronthaul network using SR-MPLS and/or SRv6 based transport and controller-based Path Calculation</li> </ol> | | | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Pre-Req</b> | <p>SR-MPLS and/or SRv6 baseline configuration on CSR, HSR and any other Fronthaul routers</p> <p>Optional Timing and syn configuration through FH network for RAN Nodes to sync if actual O-RU and O-DU are used instead of O-Ru and O-DU simulators</p> <p>SR PCE controller setup and communication with CSR/HSR through PCEP as shown in topology</p> | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A network diagram showing the test topology. It includes an O-RU (Open Radio Unit) connected to a CSR (Central Switch Router) via a 7.2x eCPRI link. The CSR is connected to an HSR (Host Switch Router) via a red line representing the fronthaul network. The HSR is connected to an O-DU (Open Distributed Unit) via a 7.2x eCPRI link. A Traffic Gen (Traffic Generator) is connected to both the CSR and the HSR. A Controller (PCE) is connected to both the CSR and the HSR via PCEP (Path Computation Element Protocol) links, indicated by dashed orange lines. The CSR and HSR are also connected to each other via a red line representing the fronthaul network." data-bbox="416 488 1297 801" src="f3f1b6d7de0937e60fc4462c4622fb1a_img.jpg"/> | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Connect O-RU or O-RU simulator to the UNI of the CSR and O-DU or O-DU simulator to the HSR.</li> <li>2. 1 or more routers should be used in the Fronthaul test network to ensure constrains based path calculation.</li> <li>3. Configure L2 transport service between CSR and HSR from O-RU Uni to O-DU Uni using L2 VPN or EVPN VPWS or both</li> <li>4. Connect an additional interface from traffic generator to the CSR and the HSR to carry the background L3VPN traffic. The CSR and HSR should be pre-configured with L3VPN services to carry this background traffic</li> <li>5. If actual O-RU and O-DU are used, connect a tester to O-RU and O-DU to send simulated UE traffic. If not, send eCPRI 7-2x traffic directly from simulators.</li> </ol> | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify O-RU and O-DU are up and communicating, if actual O-RU and O-DU are used instead of simulators.</li> <li>2. Start bi-directional traffic between the RAN nodes, verify traffic is being received on either ends using shortest IGP path between CSR and HSR.</li> <li>3. Start bi-directional eCPRI traffic through CSR and HSR between the RAN nodes, or their simulators.</li> <li>4. Verify traffic is being received on either ends using shortest IGP path between CSR and HSR.</li> <li>5. Simultaneously send background L3VPN traffic using the additional ethernet interface on CSR and HSR. Ensure that combined eCPRI and L3VPN traffic do not exceed CSR and HSR's uplink capacity</li> <li>6. Configure an SRTE policy defining a constrain based path, different than the IGP shortest path.</li> <li>7. SRTE policy should use PCE controller-based path calculation. CSR and HSR should request this path calculation from PCE based on the constraints defined.</li> <li>8. Constraints may include: <ol style="list-style-type: none"> <li>a. Include or exclude certain links.</li> <li>b. Lowest latency path (latency may be increased on the IGP shortest path to force a longer IGP path but with lower latency</li> <li>c. Use of Flex-Algo to enforce path selection.</li> </ol> </li> </ol> | + +| | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>Apply the policy to the EVPN VPWS service as well as L3VPN services, using static configuration or route-coloring.</li> <li>Execute Test cases documented in 8.1 and 8.4 using both SR-MPLS and/or SRv6 based transport</li> </ol> | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>Verify traffic used IGP best path before applying SRTE Policy.</li> <li>Verify route coloring and the use of SRTE policy for EVPN VPWS and L3VPN service between HSR and CSR once SRTE is configured.</li> <li>Verify updated path is calculated on the PCE and sent to the HSR and CSR to use with SRTE policy.</li> <li>Verify CSR and HSR install/use the path received from PCE for the SRTE policy</li> <li>Verify traffic uses updated path based on constraints defined by SRTE policy and computed by PCE controller.</li> <li>Verify SID path list accurately reflects the path used by EVPN VPWS and L3VPN traffic.</li> <li>Ensure 100% success for traffic send and received.</li> <li>The test topology and setup could be used for more granular test cases and measurements (various traffic mix, Latency, etc) documented in Sections 8.1 and 8.4.</li> </ol> | +| <b>Test Output</b> | <p>Capture configuration used for reference.</p> <p>Capture verification commands (show commands) as appropriate for:</p> <ol style="list-style-type: none"> <li>Route coloring and SRTE policy use with EVPN VPWS.</li> <li>PCEP communication between CSR/HSR and PCE</li> <li>SRTE Path calculation performed by PCE.</li> <li>SRTE Path installation and use by CSR/HSR</li> </ol> | + +### 8.2.4 L3VPN based Services Verification for Xhaul network + +This section covers the test case scenarios to be validated for L3 Service across various domains. + +L3VPN is a mature technology, hence this case should act only as a guidance and included for completeness. + +| | | | | +|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|----------------| +| <b>Test ID</b> | Ethernet.L3VPN.01 | <b>Classification</b> | L3VPN Services | +| <b>Test Title</b> | L3VPN Services verification | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>Verify L3VPN services for FH (M-Plane only), MH and BH over SR-MPLS and SRv6</li> <li>Test could be repeated for constraints-based Path using SR-TE with Headend and/or controller-based path computation</li> </ol> | | | +| <b>Pre-Req</b> | SR-MPLS and/or SRv6 baseline configuration on FH, MH and BH routers | | | + +| | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>Timing and syn configuration through FH network for RAN Nodes to sync if actual O-RU, O-DU and O-CU are used.</p> <p>L3VPN services configuration as shown in the test topology</p> | +| <b>Test Topology:</b> | <p>Either of the two test topologies shown could be used.</p> <p>First topology is for L3VPN Service across all the domains, second topology is for 1 domain if testing if cross domains is not preferred.</p> <p>Topology Choice1:</p> <img alt="Topology Choice 1: A network diagram showing three domains: VPN1 (blue), VPN2 (orange), and VPN3 (green). VPN1 is connected to VPN2, which is connected to VPN3. The domains are connected via FrontHaul, MidHaul, and Backhaul. The FrontHaul connects O-RU (O-RAN Units) to O-DU (O-RAN Distributed Units) at the Hub Site. The MidHaul connects O-DU to O-CU (O-RAN Central Units) at the Edge DC. The Backhaul connects O-CU to PE Routers at the Regional DC. A 5G and/or Transport Core is also shown." data-bbox="414 526 1252 817" src="27d1de573ca1b667211a0b0e851ad52e_img.jpg"/> <p>Topology Choice2:</p> <img alt="Topology Choice 2: A network diagram showing two RAN Nodes connected via TNE (Transport Network Elements). The RAN Nodes are connected to a Traffic Gen (Traffic Generator). The TNEs are connected to a central node labeled 'Fronthaul, Midhaul or Backhaul Domain With L3VPN service'." data-bbox="414 918 1284 1164" src="7c36a66dce4bcf2a43291f6a814835ca_img.jpg"/> | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>As shown in the topology</li> <li>Configure L3VPN services as desired</li> </ol> | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>Verify O-RU, O-DU and O-CU are up and communicating if actual devices are used. Else connect traffic simulator to appropriate RAN nodes.</li> <li>Start bi-directional traffic between the RAN nodes, verify traffic is being received on all ends.</li> <li>Execute Test cases documented in Section 0 and 8.4 using both SR-MPLS and/or SRv6 based transport.</li> <li>Execute the test case with Constraints based path calculation for: <ol style="list-style-type: none"> <li>Headend based Path Computation</li> <li>Controller based path computation.</li> <li>Constraints may include, but not limited: <ol style="list-style-type: none"> <li>Include or exclude certain links.</li> <li>Lowest latency path (latency may be increased on the IGP shortest path to force a longer IGP path but with lower latency)</li> <li>Use of Flex-Algo to enforce path selection.</li> </ol> </li> </ol> </li> </ol> | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>100% successful traffic transport between O-RU, O-DU and O-CU</li> <li>Verify traffic stats on: <ol style="list-style-type: none"> <li>Test equipment</li> </ol> </li> </ol> | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>b. O-RU, O-DU and O-CU, if used</li> <li>c. TNE devices in the CSR and HSR interface and L2VPN/EVPN VPWS service counters</li> </ul> <p>3. The test topology and setup could be used for more granular test cases and measurements (various traffic mix, Latency, etc) documented in Section 8.4.</p> | +| <b>Test Output</b> | <p>Capture configuration used for reference.</p> <p>Capture verification commands (show commands) as appropriate.</p> <p>For SRTE constraints based testcases verify:</p> <ul style="list-style-type: none"> <li>1. Route coloring and SRTE policy use with L3VPN services.</li> <li>2. L3VPN Path calculation at the headend (With headend based path calculation)</li> <li>3. PCEP communication between various TNE and PCE (for controller-based Path computation)</li> <li>4. SRTE Path calculation performed by PCE (for controller-based Path computation)</li> <li>5. SRTE Path installation and use by TNE's (for controller-based Path computation)</li> </ul> | + +## 8.3 Network element testing + +### 8.3.1 Frame Pre-emption Testing + +| | | | | +|------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|----------------------------| +| <b>Test ID</b> | ETH.PREEMPT.01 | <b>Classification</b> | Ethernet, Frame Preemption | +| <b>Test Title</b> | Fragmentation of latency sensitive Fronthaul traffic by other background traffic by TNE supporting TSN profile B | | | +| <b>Test Objective:</b> | Verify fragmentation capability of TNE supporting TSN profile B while queuing delay for latency sensitive Fronthaul traffic is bounded by 155 bytes transmission time at egress port | | | +| <b>Pre-Req</b> | TNE supporting TSN profile B. This test needs to be done only at TNE interface speed of 1 Gbps/10 Gbps/25 Gbps. | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A blue box labeled 'TNE' is connected to a grey box labeled 'Traffic Generator and Analyzer'. The connection is a loop with three numbered points: 1 at the TNE input, 2 at the Traffic Generator and Analyzer input, and 3 at the TNE output. The interface speed is 1Gbps/10Gbps/25Gbps." data-bbox="477 1516 1203 1975" src="d789e03a60e01679a1588818f0026e48_img.jpg"/> <p>Interface speed: 1Gbps/10Gbps/25Gbps</p> | | | + +Image: O-RAN Alliance Logo + +O-RAN.WG9.XTRP-TST.0-R004-v05.00 +**Test Configuration** +This section to be filled out when putting the test report (may include device and/or tester configuration) +**Procedure:** + +**Detailed Test procedure:** + +- Enable TSN profile B and Frame Preemption with add FragSize = 0 in TNE. +- Configure TNE to classify ingress traffic as express traffic and preemptible traffic. The classification could be based on incoming port, VLAN in ingress traffic or VLAN priority of incoming traffic. +- Configure preemptible traffic in burst mode on traffic generator port 1 according to the table below. +- Configure express traffic in burst mode on traffic generator port 2 according to the table below. +- Send only express traffic stream from the traffic generator port 2 and measure latency port 3 of traffic generator. This latency consists of all four delay components such as frame transmission delay, self-queueing delay, queuing delay and store-and-forward delay. In absence of other traffic, queueing delay can be assumed zero. +- Start preemptible traffic stream and then express traffic stream. Observe some preemptible frames are fragmented. Measure latency of express frames. + +| Express frame size (in bytes) | Express frame count in burst | Preemptible Frame Size (in bytes) | Preemptible frame count in burst | +|-------------------------------|------------------------------|-----------------------------------|----------------------------------| +| 64 | 1000 | 123 | 10000 | +| 64 | 1000 | 124 | 10000 | +| 64 | 1000 | 1000 | 10000 | +| 64 | 1000 | 4500 | 10000 | +| 64 | 1000 | 9000 | 10000 | +| 500 | 1000 | 4500 | 10000 | +| 500 | 1000 | 9000 | 10000 | +| 2000 | 1000 | 4500 | 10000 | +| 2000 | 1000 | 9000 | 10000 | + +**Verifications needed:** +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. +86 + +| | <ol style="list-style-type: none"> <li>1. Verify that at least some preemptible frames are fragmented (except when preemptible frame size is 123 bytes)</li> <li>2. Verify that difference between worst case latency of express frames and latency measured in step 5 is no more than 155 bytes transmission time. In the table below, 155 bytes transmission time on different line speed is mentioned.</li> </ol><br><table border="1"> <thead> <tr> <th>Port speed</th> <th>Transmission time of 155 bytes</th> </tr> </thead> <tbody> <tr> <td>1 Gbps</td> <td>1.24 μs</td> </tr> <tr> <td>10 Gbps</td> <td>0.124 μs</td> </tr> <tr> <td>25 Gbps</td> <td>0.05 μs</td> </tr> </tbody> </table> | Port speed | Transmission time of 155 bytes | 1 Gbps | 1.24 μs | 10 Gbps | 0.124 μs | 25 Gbps | 0.05 μs | +|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------|--------------------------------|--------|---------|---------|----------|---------|---------| +| Port speed | Transmission time of 155 bytes | | | | | | | | | +| 1 Gbps | 1.24 μs | | | | | | | | | +| 10 Gbps | 0.124 μs | | | | | | | | | +| 25 Gbps | 0.05 μs | | | | | | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if some of preemptible traffic is fragmented and queuing delay of fronthaul traffic is bounded by 155 bytes transmission time on egress port. 155 bytes transmission time at individual line speed is mentioned in the table above. | | | | | | | | | +| <b>Test Output</b> | This section is the placeholder that will capture the output/configurations after test is executed, typically done after test execution | | | | | | | | | + +| | | | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|----------------------------| +| <b>Test ID</b> | ETH.PREEMPT.02 | <b>Classification</b> | Ethernet, Frame Preemption | +| <b>Test Title</b> | Reassembly of preemptible traffic by TNE supporting TSN profile B | | | +| <b>Test Objective:</b> | Verify reassembly capability of TNE supporting TSN profile B | | | +| <b>Pre-Req</b> | TNE supporting TSN profile B. This test needs to be done only at TNE interface speed of 1 Gbps/10 Gbps/25 Gbps. | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A blue box labeled 'TNE' is connected to a grey box labeled 'Traffic Generator and Analyzer' via a green line loop. The connection is labeled '1' at the TNE end and '2' at the other end of TNE. Below the diagram, it says 'Interface speed: 1Gbps/10Gbps/25Gbps'." data-bbox="414 1456 1037 1859" src="4a5978aadfd00e76db821f87ccd70e6e_img.jpg"/> <p>Interface speed: 1Gbps/10Gbps/25Gbps</p> | | | +| <b>Test Configuration</b> | This section to be filled out when putting the test report (may include device and/or tester configuration) | | | + +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Enable TSN profile B and Frame Preemption on TNE port 1 and disable frame preemption on TNE port 2</li> <li>2. From a tester port send interspersed fragments from same preemptible frame and express frames of various size according to the table below. Measure latency of express frames in case.</li></ol> <table border="1" data-bbox="448 501 1426 775"> <thead> <tr> <th>Preemptible Frame Size (in bytes)</th><th>Fragment size (in bytes)</th><th>Fragment count interspersed with express frame size</th><th>Express Frame size interspersed with fragments (in bytes)</th></tr> </thead> <tbody> <tr> <td>256</td><td>64</td><td>4</td><td>64 to 2000</td></tr> <tr> <td>2048</td><td>128</td><td>8</td><td>64 to 2000</td></tr> <tr> <td>5000</td><td>256</td><td>8</td><td>64 to 2000</td></tr> </tbody> </table> <ol style="list-style-type: none"> <li>3. For each express frame size, also configure and send express traffic without any interspersed fragments or preemptible traffic. Measure latency of express traffic.</li> <li>4. Observe latency experienced by reassembled frames by considering receive time of last bit of last fragment in the DUT and the last bit of reassembled frame in traffic generator port.</li></ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that TNE reassembles all the fragments and sends out a preemptible frame successfully on egress port for each combination.</li> <li>2. Verify that express frame experiences almost same latency in step 2 as in step 3 since reassembly must not affect express frame latency.</li> <li>3. Recorded latency in step 4 is only for information since there is no limit imposed on latency of fragmented frames.</li></ol> | Preemptible Frame Size (in bytes) | Fragment size (in bytes) | Fragment count interspersed with express frame size | Express Frame size interspersed with fragments (in bytes) | 256 | 64 | 4 | 64 to 2000 | 2048 | 128 | 8 | 64 to 2000 | 5000 | 256 | 8 | 64 to 2000 | +|-----------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------|-----------------------------------------------------------|-----------------------------------------------------|-----------------------------------------------------------|-----|----|---|------------|------|-----|---|------------|------|-----|---|------------| +| Preemptible Frame Size (in bytes) | Fragment size (in bytes) | Fragment count interspersed with express frame size | Express Frame size interspersed with fragments (in bytes) | | | | | | | | | | | | | | | +| 256 | 64 | 4 | 64 to 2000 | | | | | | | | | | | | | | | +| 2048 | 128 | 8 | 64 to 2000 | | | | | | | | | | | | | | | +| 5000 | 256 | 8 | 64 to 2000 | | | | | | | | | | | | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if above verification steps are successful | | | | | | | | | | | | | | | | | +| <b>Test Output</b> | This section is the placeholder that will capture the output/configurations after test is executed, typically done after test execution | | | | | | | | | | | | | | | | | + +### 8.3.1 Auto-negotiation + +| | | | | +|------------------------|-------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Ethernet.AUTONEG.01 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Auto-negotiation | | | +| <b>Test Objective:</b> | The aim of the test is to check the system behavior after fiber network link disconnection/connection | | | + +| | | +|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Pre-Req</b> | Running service will be interrupted | +| <b>Test Topology:</b> | <p style="text-align: center;"><b>TNE</b></p> <img alt="Test Topology Diagram: A diagram showing a Traffic generator/Analyser connected to a stack of boards (Board 1, Board 2, etc.) within a TNE. The connection is labeled with '1 / 10 / 25 / 100 GbE' on both sides." data-bbox="427 353 730 716" src="8a682c8df87944123ae36898b25a5a7d_img.jpg"/> | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Check the configuration, devices should support auto-negotiation mode.</li> <li>2. Enable the auto-negotiation of the port.</li> <li>3. Connect various link (port rate, duplex mode) of an Ethernet port.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify if the port automatically negotiates the force mode</li> </ol> | +| <b>Test Configuration</b> | IEEE 802.3 | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1. Devices must support auto-negotiation mode.</li> <li>2. Port must automatically negotiate the force mode</li> </ol> | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | +| <b>Test Output</b> | | + +## 8.4 Additional Network testing + +- Traffic configuration + - Backhaul and midhaul traffic profile. + - O-RAN fronthaul traffic profile +- Jumbo frame +- Auto-negotiation +- Frame Loss +- Latency TNE at minimum distance (0km) +- Throughput +- Latency TNE at 1, 10 and 20 km distance + +1 + +### 8.4.1 Latency TNE at 1, 10 and 20 km distance + +| | | | | +|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Ethernet.LAT.01 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Latency TNE with Xhaul link | | | +| <b>Test Objective:</b> | The aim of the test is to check the maximum latency at which the TNE receives and forwards frames with no frame loss per packet size with Xhaul link (fiber or Microwave link) | | | +| <b>Pre-Req</b> | Running service will be interrupted | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNEs connected via an XHAUL LINK. Each TNE contains a stack of CU, DU, and RU blocks, and two boards (Board 1 and Board 2). The XHAUL LINK is labeled with distances 1km, 10km, and 20km. A Traffic generator/Analyser is connected to both TNEs via 1/10/25/100 GbE links. The diagram also shows connections to NGC/EPC and O-RU/DU/CU." data-bbox="422 638 1268 1176" src="0b7b74ebde9a2cd1c680ac6c43c6b594_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>1. TNE is connected to another TNE or O-RU/DU/CU & NGC/EPC by 1, 10 and 20 km using fibre loop or microwave link, all services are running as defined in Traffic and services configuration.</li> <li>2. Send traffic for size of frames from 70 to 1522 bytes (70, 100, 250, 300, 400, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300, 1400, 1500, 1522) frame size. Traffic should be bidirectional.</li> <li>3. The test should be at least 120 seconds in duration.</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Make measure and report Maximum Latency Rx and Tx rate for each size of frames in included table.</li> <li>2. Make measure and report Minimum Latency Rx and Tx rate for each size of frames in included table.</li> <li>3. Make measure and report Average Latency Rx and Tx rate for each size of frames in included table</li> </ol> | | | +| <b>Test Configuration</b> | RFC2544 | | | +| <b>Pass/Fail Criteria:</b> | <ol style="list-style-type: none"> <li>1- Latency MUST be below 1ms</li> <li>2- Latency SHOULD be in terms of tens of microseconds</li> </ol> | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | + +| Test Output | frame size | Latency | | | | | | +|-------------|------------|--------------|--------------|--------------|--------------|--------------|--------------| +| | | Upstream | | | Downstream | | | +| | | Average (us) | Minimum (us) | Maximum (us) | Average (us) | Minimum (us) | Maximum (us) | +| | 1522 | | | | | | | +| | 1400 | | | | | | | +| | 1300 | | | | | | | +| | 1200 | | | | | | | +| | 1100 | | | | | | | +| | 1000 | | | | | | | +| | 900 | | | | | | | +| | 800 | | | | | | | +| | 700 | | | | | | | +| | 600 | | | | | | | +| | 500 | | | | | | | +| | 400 | | | | | | | +| | 300 | | | | | | | +| | 200 | | | | | | | +| | 100 | | | | | | | +| | 70 | | | | | | | + +### 8.4.2 VLAN Manipulation Tests + +| | | | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------| +| <b>Test ID</b> | Ethernet.VLAN.01 | <b>Classification</b> | Functional | +| <b>Test Title</b> | VLAN manipulation for eCPRI EVPN VPWS service | | | +| <b>Test Objective:</b> | Validate VLAN manipulation (pop 1, pop 2, push 1, push2, translate 1 to 1, 1 to 2, 2 to 1, 1 to 2) | | | +| <b>Pre-Req</b> | eCPRI EVPN VPWS service between CSR and HSR up and running | | | +| <b>Test Topology:</b> | <img alt="Network topology diagram showing eCPRI flow and EVPN VPWS service between a Cell site (O-RU, CSR) and a Hub site (HSR, O-DU) via a Fronthaul cloud. The Cell site includes VLAN manipulation and Untagged 802.1Q QinQ. The Hub site includes HSR and O-DU." data-bbox="411 638 1417 1003" src="09edf50d80d00c87f36b83756b9a658a_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <p>Please note the following test steps partially use commands that are specific to a particular vendor. They can certainly be replaced by the commands of equipment deployed by the users of this document.</p> <p>Perform the following VLAN translations.</p> <ul style="list-style-type: none"> <li>pop 1</li> <li>pop 2</li> <li>push 1 (VLAN 1100)</li> <li>push 2 (VLAN 1101.2101)</li> <li>translate 1 to 1 (VLAN 1102)</li> <li>translate 1 to 2 (VLAN 1103.2103)</li> <li>translate 2 to 1 (VLAN 1104)</li> <li>translate 2 to 2 (VLAN 1105)</li> </ul> <p>This test shall be performed on the eCPRI EVPN VPWS service between CSR and HSR.</p> <p><b>Verifications needed:</b></p> <p>Confirm via traffic generator that there is connectivity (i.e. eCPRI traffic is flowing bidirectionally end-to-end across EVPN VPWS service between emulated O-RU and emulated O-DU).</p> | | | +| <b>Test Configuration</b> | <p><b>pop 1</b></p> <pre>kszakowicz@AN17-re0# show interfaces ae1 unit 1600</pre> | | | + +| | <pre> W50: Thu 2014-12-11T16:29:48 WET (UTC+0000) encapsulation vlan-ccc; vlan-tags outer 0x8100:1681 inner 0x8100:1600; input-vlan-map pop; output-vlan-map { push; tag-protocol-id 0x8100; inner-tag-protocol-id 0x8100; } pop 2 kszarkowicz@AN17-re0# show interfaces ae1.1603 W50: Thu 2014-12-11T16:22:36 WET (UTC+0000) encapsulation vlan-ccc; vlan-tags outer 0x8100:1681 inner 0x8100:1603; input-vlan-map pop-pop; output-vlan-map { push-push; tag-protocol-id 0x8100; inner-tag-protocol-id 0x8100; } </pre> | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------|--------------|--------------|--------------|--------------|-----------|--------------|--------|---|-------------------------|--------------------------|-----------|--------------|--------------|---|--|---|--------------------------|-------------------------|-----------|--------------|--------------|---|--|---|------------------|-------------------|-----|-------------|-------------|---|--|---|-------------------|------------------|-----|-------------|-------------|---|--|---|---------------------|-------------------------|-----------|---|---|---|--|---|-------------------------|---------------------|-----------|---|---|---|--|---|---------------------|-------------------------|-----------|------------|------------|---|--|---|-------------------------|---------------------|-----------|------------|------------|---|--| +| <b>Pass/Fail Criteria:</b> | Traffic flows via EVPN VPWS service with all VLAN manipulation combinations. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| <b>Results</b> | [ X ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| <b>Test Output</b> | <table border="1"> <thead> <tr> <th></th><th>Tx Port</th><th>Rx Port</th><th>Traffic Item</th><th>Tx Frames</th><th>Rx Frames</th><th>Frames Delta</th><th>Loss %</th></tr> </thead> <tbody> <tr> <td>1</td><td>100GE - Broadband MX240</td><td>100GE - Broadband ACX710</td><td>Broadband</td><td>1,492,928...</td><td>1,492,928...</td><td>0</td><td></td></tr> <tr> <td>2</td><td>100GE - Broadband ACX710</td><td>100GE - Broadband MX240</td><td>Broadband</td><td>1,492,928...</td><td>1,492,928...</td><td>0</td><td></td></tr> <tr> <td>3</td><td>10GE - LTE MX240</td><td>10GE - LTE ACX710</td><td>LTE</td><td>191,948,290</td><td>191,948,290</td><td>0</td><td></td></tr> <tr> <td>4</td><td>10GE - LTE ACX710</td><td>10GE - LTE MX240</td><td>LTE</td><td>191,948,290</td><td>191,948,290</td><td>0</td><td></td></tr> <tr> <td>5</td><td>10GE - eCPRI ACX710</td><td>10GE - eCPRI ACX5448-16</td><td>eCPRI 1-2</td><td>0</td><td>0</td><td>0</td><td></td></tr> <tr> <td>6</td><td>10GE - eCPRI ACX5448-16</td><td>10GE - eCPRI ACX710</td><td>eCPRI 1-2</td><td>0</td><td>0</td><td>0</td><td></td></tr> <tr> <td>7</td><td>10GE - eCPRI ACX710</td><td>10GE - eCPRI ACX5448-24</td><td>eCPRI 1-3</td><td>71,855,403</td><td>71,855,403</td><td>0</td><td></td></tr> <tr> <td>8</td><td>10GE - eCPRI ACX5448-24</td><td>10GE - eCPRI ACX710</td><td>eCPRI 1-3</td><td>71,959,914</td><td>71,959,914</td><td>0</td><td></td></tr> </tbody> </table> | | Tx Port | Rx Port | Traffic Item | Tx Frames | Rx Frames | Frames Delta | Loss % | 1 | 100GE - Broadband MX240 | 100GE - Broadband ACX710 | Broadband | 1,492,928... | 1,492,928... | 0 | | 2 | 100GE - Broadband ACX710 | 100GE - Broadband MX240 | Broadband | 1,492,928... | 1,492,928... | 0 | | 3 | 10GE - LTE MX240 | 10GE - LTE ACX710 | LTE | 191,948,290 | 191,948,290 | 0 | | 4 | 10GE - LTE ACX710 | 10GE - LTE MX240 | LTE | 191,948,290 | 191,948,290 | 0 | | 5 | 10GE - eCPRI ACX710 | 10GE - eCPRI ACX5448-16 | eCPRI 1-2 | 0 | 0 | 0 | | 6 | 10GE - eCPRI ACX5448-16 | 10GE - eCPRI ACX710 | eCPRI 1-2 | 0 | 0 | 0 | | 7 | 10GE - eCPRI ACX710 | 10GE - eCPRI ACX5448-24 | eCPRI 1-3 | 71,855,403 | 71,855,403 | 0 | | 8 | 10GE - eCPRI ACX5448-24 | 10GE - eCPRI ACX710 | eCPRI 1-3 | 71,959,914 | 71,959,914 | 0 | | +| | Tx Port | Rx Port | Traffic Item | Tx Frames | Rx Frames | Frames Delta | Loss % | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| 1 | 100GE - Broadband MX240 | 100GE - Broadband ACX710 | Broadband | 1,492,928... | 1,492,928... | 0 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| 2 | 100GE - Broadband ACX710 | 100GE - Broadband MX240 | Broadband | 1,492,928... | 1,492,928... | 0 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| 3 | 10GE - LTE MX240 | 10GE - LTE ACX710 | LTE | 191,948,290 | 191,948,290 | 0 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| 4 | 10GE - LTE ACX710 | 10GE - LTE MX240 | LTE | 191,948,290 | 191,948,290 | 0 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| 5 | 10GE - eCPRI ACX710 | 10GE - eCPRI ACX5448-16 | eCPRI 1-2 | 0 | 0 | 0 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| 6 | 10GE - eCPRI ACX5448-16 | 10GE - eCPRI ACX710 | eCPRI 1-2 | 0 | 0 | 0 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| 7 | 10GE - eCPRI ACX710 | 10GE - eCPRI ACX5448-24 | eCPRI 1-3 | 71,855,403 | 71,855,403 | 0 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| 8 | 10GE - eCPRI ACX5448-24 | 10GE - eCPRI ACX710 | eCPRI 1-3 | 71,959,914 | 71,959,914 | 0 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | +| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | + +### 8.4.3 QoS testing + +| | | | | +|------------------------|-------------------------------------------------------|-----------------------|-----| +| <b>Test ID</b> | Ethernet.QOS.01 | <b>Classification</b> | QoS | +| <b>Test Title</b> | End to end latency, loss of classified traffic | | | +| <b>Test Objective:</b> | Verify end to end latency, loss of classified traffic | | | +| <b>Pre-Req</b> | Each TNE supporting QoS in Xhaul Transport Network | | | + +| <b>Test Topology:</b> | <img alt="Diagram of Xhaul Transport Network topology. A central cloud labeled 'Xhaul Transport Network' is connected to two external networks: 'Ports carrying Ingress traffic towards transport network' on the left and 'Ports carrying egress traffic outwards transport network' on the right. A 'Traffic Generator and Analyzer' block is connected to the bottom of the cloud." data-bbox="443 280 1410 790" src="d1f701d72fab4f1cff3347d7790b844a_img.jpg"/> | | | | | | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------|--------------------------------------|----------|--|--|--| +| <b>Test Configuration</b> | This section to be filled out when putting the test report (may include device and/or tester configuration) | | | | | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>Enable QoS in each TNE (core and edge devices) with operator specific scheme and connect traffic generator ports at the edge of the transport network.</li> <li>Configure continuous traffic flows in traffic generator which would be mapped to strict priority queue(s) with a rate equal to the configured rate in policing/shaping at edge TNE(s). In case of Ethernet traffic, VLAN PCP bits/ VLAN ID/ingress port ID could be used for traffic classification in edge TNE. In case of IPv4 traffic, DSCP bits/ingress port could be used for traffic classification in edge TNE. Rate and size of these flows would be operator's choice based upon deployment scenario.</li> <li>Configure continuous traffic flows in traffic generator which would be mapped to WRR/WFQ/MDRR queue(s) with rate more than configured rate of each of these queue(s) so that traffic congestion occurs in core. In case of Ethernet traffic, VLAN PCP bits/ VLAN ID/ingress port ID could be used for traffic classification in edge TNE. In case of IPv4 traffic, DSCP bits/ingress port could be used for traffic classification in edge TNE. Rate and size of these flows would be operator's choice based upon deployment scenario.</li> <li>Create latency bins in traffic generator rx port for each traffic flows based on expected latency range and traffic marking such as PCP bits, IPv4 DSCP bits etc. Latency ranges are decided by operator based upon deployment scenario. For example, if latency class for fronthaul traffic is "High25", then a latency bin must be created with 0-25 us range. Other possible two bins could be 25 – 500 us and 500-max us for traffic flows other than latency sensitive ones. Table 3 of Xhaul Transport Requirement Doc is repeated here that helps in identifying latency bins in case of fronthaul traffic.</li> </ol> <table border="1" data-bbox="416 1975 1393 2051"> <thead> <tr> <th style="background-color: #8faadc;">Latency Class</th><th style="background-color: #8faadc;">Max. One-way Frame Delay Performance</th><th style="background-color: #8faadc;">Use case</th></tr> </thead> <tbody> <tr> <td> </td><td> </td><td> </td></tr> </tbody> </table> | Latency Class | Max. One-way Frame Delay Performance | Use case | | | | +| Latency Class | Max. One-way Frame Delay Performance | Use case | | | | | | +| | | | | | | | | + +| | | | | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------|-----------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------| +| | High25 | 25 us | Ultra-low latency performance | +| | High75 | 75 us | For full NR performance with fiber lengths in 10km range | +| | High100 | 100 us | For standard NR performance with fiber lengths in 10km range | +| | High200 | 200 us | For installations with fiber lengths in 30km range | +| | High500 | 500 us | Large latency installations > 30 km | +| | Medium | User Plane (slow) & C&M Plane (fast) | 1 ms | +| | Low | C&M Plane | 100 ms | +| <p>5. Send all the traffic flows simultaneously. Observe packets/frames received in each latency bins. Also observe loss in each traffic flows</p> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Latency sensitive traffics which are mapped to strict priority queue(s) must not suffer any frame loss.</li> <li>2. All Latency sensitive traffic frames which are mapped to strict priority queue(s) must be received in respective configured latency bins in traffic generator.</li> <li>3. Traffic frames mapped to WRR/WFQ/MDRR queue(s) must maintain a long term receive rate equal to the configured rate in those queues. Due to congestion excess traffic would be dropped and loss is reported in traffic generator for these traffic flows.</li> <li>4. Latency reported for traffic flows mapped to WRR/WFQ/MDRR queues in general must be higher than that of traffic flows mapped to strict priority queue(s)</li> </ol> | | | | +| <b>Pass/Fail Criteria:</b> | | Test shall pass if all verifications steps pass | | +| <b>Test Output</b> | | This section is the placeholder that will capture the output/configurations after test is executed, typically done after test execution | | + +### 8.4.4 Jitter Testing + +This test case is FFS as it needs inputs from WG4 CUS-Specification team on the maximum jitter (packet delay variation) acceptable at an O-RU Fronthaul UNI. Future versions of this document may update this section as inputs from WG4 become available, + +| <b>Test ID</b> | Ethernet.JIT.01 | <b>Classification</b> | Functionality | | | | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------|------------|----------------------|------|--| +| <b>Test Title</b> | Delay variation | | | | | | | +| <b>Test Objective:</b> | The aim of the test is to check the delay variation at which the TNE receives frames with no frame loss per packet size | | | | | | | +| <b>Pre-Req</b> | N/A | | | | | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: Two TNEs connected via an XHAUL LINK. Each TNE contains a CU, DU, and RU stack. Below the stack are Board 1 and Board 2. A yellow line connects Board 1 of both TNEs. A Traffic generator/Analyser is connected to both Board 1 and Board 2 of both TNEs via green lines labeled '1 / 10 / 25 / 100 GbE'." data-bbox="422 504 1268 1041" src="ca721d0a8da02016a9cf29dd1329f081_img.jpg"/> | | | | | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. TNE is connected to another TNE. Two services are defined, one representing the Xhaul traffic, the other one representing background traffic.</li> <li>2. Xhaul and background traffic are marked with different QoS values, being the Xhaul traffic of higher priority vs the background traffic.</li> <li>3. Send traffic for size of frames from 70 to 1522 bytes (70, 100, 250, 300, 400, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300, 1400, 1500, 1522) frame size. Traffic should be bidirectional.</li> <li>4. The test should be at least 120 seconds in duration.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Make measure and report Maximum Jitter Rx and Tx rate for each size of frames in included table</li> </ol> | | | | | | | +| <b>Test Configuration</b> | RFC3393 | | | | | | | +| <b>Pass/Fail Criteria:</b> | 1- Jitter SHOULD be below TBD microseconds | | | | | | | +| <b>Results</b> | [ X ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | | | | | +| <b>Test Output</b> | <table border="1" style="margin-left: auto; margin-right: auto;"> <thead> <tr> <th>Frame size</th><th>Observed Jitter (µs)</th></tr> </thead> <tbody> <tr> <td>1522</td><td></td></tr> </tbody> </table> | | | Frame size | Observed Jitter (µs) | 1522 | | +| Frame size | Observed Jitter (µs) | | | | | | | +| 1522 | | | | | | | | + +| | | | | +|--|--|------|--| +| | | 1400 | | +| | | 1300 | | +| | | 1200 | | +| | | 1100 | | +| | | 1000 | | +| | | 900 | | +| | | 800 | | +| | | 700 | | +| | | 600 | | +| | | 500 | | +| | | 400 | | +| | | 300 | | +| | | 200 | | +| | | 100 | | +| | | 70 | | + +1 + +2 + +3 + +### 8.4.5 Test for frame fragmentation + +| Test ID | Ethernet.FRAG.01 | Classification | Functionality | +|-----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Impact of fragmentation | | | +| Test Objective: | The aim of the test is to check the impacts of frame fragmentation in throughput, latency and delay variation with no frame loss per packet size (frame fragmentation occurs in the link between TNEs) | | | +| Pre-Req | N/A | | | + +| | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: Two TNEs connected via an XHAUL LINK. Each TNE contains Board 1 and Board 2. A Traffic generator/Analyser is connected to both TNEs. The diagram shows various MTU configurations: 1/10/25/100 GbE and 1/10/25/100 GbE. The XHAUL LINK connects the two TNEs." data-bbox="422 257 1173 728" src="1ca583c2983f90cd6f131dcd1fd15936_img.jpg"/> | +| <b>Procedure:</b> | <p><u><b>Detailed Test procedure:</b></u></p> <p><u><b>Test Procedure:</b></u></p> <ol style="list-style-type: none"> <li>1. TNE is connected to another TNE, and the MTU among them is lowr than the MTU allow at client side (i.e., O-RU / O-DU / O-CU).</li> <li>2. Two frame sizes are established, one for client side and another one between TNEs.</li> <li>3. Send traffic for size higher MTU at sending client port and verify permitted MTU at receiver port.</li> <li>4. The test should be at least 120 seconds in duration.</li> </ol> <p><u><b>Verifications needed:</b></u></p> <ol style="list-style-type: none"> <li>1. Make measure and report throughput, latency and jitter with and without fragmentation</li> </ol> | +| <b>Test Configuration</b> | | +| <b>Pass/Fail Criteria:</b> | 1- | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | +| <b>Test Output</b> | | + +###### 1 8.4.6 Test for encapsulations and protocols + +| | | | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Ethernet.ENC.01 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Impacts of encapsulations and protocols used | | | +| <b>Test Objective:</b> | <p>The aim of the test is to check the impacts due to the usage of different encapsulations and protocols for the establishing the communication between O-RU, O-DU and O-CU.</p> <p>This test applies as pre-condition to the tests on latency, jitter and throughput.</p> | | | +| <b>Pre-Req</b> | N/A | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNEs (O-RU, O-DU, O-CU) connected via an XHAUL LINK. Each TNE contains two boards (Board 1, Board 2). A Traffic generator/Analyser is connected to the boards via 1/10/25/100 GbE links. The diagram also shows connections to NGC/EPC." data-bbox="422 683 1173 1153" src="85333c683b8a4799eaaa0ffaaf2f5f8a_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>3. Define a proper technology selection for both O-RU <-> O-DU and O-DU <-> O-CU communication.</li> <li>4. Perform the tests for latency, jitter and throughput, collecting the information indicated for their respective tests.</li> <li>5. The test should be at least 15 min in duration.</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Validate the configured solution.</li> <li>2. Make measure and report traffic passing rate for each size of frames in included table</li> </ol> | | | +| <b>Test Configuration</b> | <p>Potential protocols and encapsulations are listed here below.</p> <ul style="list-style-type: none"> <li>• Ethernet traffic (e.g., eCPRI between O-RU and O-DU)</li> <li>• (UDP/) IP traffic (e.g., eCPRI between O-RU and O-DU)</li> <li>• TSN capabilities between TNEs</li> <li>• FlexE connectivity between TNEs</li> <li>• SR-MPLS encapsulation between TNEs</li> <li>• SRv6 encapsulation between TNEs</li> <li>• L2 VPN between TNEs (e.g., for midhaul connection)</li> <li>• L3 VPN between TNEs (e.g., for midhaul connection)</li> </ul> | | | + +| | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ul style="list-style-type: none"> <li>• EVPN between TNEs (e.g., for eCPRI connection)</li> </ul> | +| <b>Pass/Fail Criteria:</b> | Compare the results obtained for latency, jitter and throughput for the different selected combinations. Particular criteria defined for latency, jitter and throughput apply. | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | +| <b>Test Output</b> | The output of the tests will be the set of tables defined for latency, jitter and throughput, for each of the selected combinations of protocols and encapsulations. | + +1 + +2 + +### 8.4.7 Addition of background traffic + +To check if specific tests is needed or simply to amend existing ones. + +| | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Ethernet.BAC.01 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | System behavior with the presence of background traffic | | | +| <b>Test Objective:</b> | <p>The aim of the test is to check the impacts due to the introduction of background traffic in the system. This background traffic can represent other kinds of traffic present on the TNEs (e.g., LTE traffic, enterprise traffic, fixed service traffic, etc). This test applies as complements the tests on latency, jitter and throughput.</p> | | | +| <b>Pre-Req</b> | <p>Identify the proportion and the marking of the background traffic under consideration. Each network can have different scopes, thus influencing on the kind of background traffic under consideration.</p> | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing two TNEs connected via an XHAUL LINK. Each TNE contains a stack of CU, DU, and RU. The TNEs are connected to a Traffic generator/Analyser. The diagram also shows connections to NGC/EPC and various network interfaces (1/10/25/100 GbE)." data-bbox="419 779 1165 1254" src="da9c6ad0046b59c27b6c5c81f5864932_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>1. Define the kind of background traffic under consideration (e.g., LTE, enterprise, fixed, etc). Identify peak/average traffic volumes as well as applicable marking.</li> <li>2. Perform the tests for latency, jitter and throughput adding this background traffic collecting the information indicated for their respective tests.</li> <li>3. The test should be at least 15 min in duration.</li> </ol> <p>Alternative test – to fill the link between TNEs.</p> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Validate the kind of background traffic introduced in the test.</li> <li>2. Make measure and report traffic passing rate for each size of frames in included table, comparing with the scenario where no background traffic is considered.</li> </ol> | | | +| <b>Test Configuration</b> | | | | +| <b>Pass/Fail Criteria:</b> | <p>Compare the results obtained for latency, jitter and throughput for the scenarios with and without background traffic.</p> | | | +| <b>Results</b> | <p>[ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed</p> | | | + +#### **Test Output** + +The output of the tests will be the set of tables defined for latency, jitter and throughput, not repeated here for simplicity. + +1 + +2 + +### 8.4.8 Support of native IPv6 connectivity + +| | | | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Ethernet.IPv6.01 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Native support of IPv6 connectivity | | | +| <b>Test Objective:</b> | <p>The aim of the test is to check the impacts due to the usage of IPv6 in O-RU, O-DU and O-CU. IPv6 support is optional in ORAN-WG4.CUS.</p> <p>This is a functional test but can also have performance implications to be validated by collecting statistics of latency, jitter and throughput.</p> | | | +| <b>Pre-Req</b> | Support of native IPv6 in TNEs | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A diagram showing the test setup. On the left, a stack of O-RAN components (CU, DU, RU) is connected to a TNE (Network Element). This TNE is connected via an XHAUL LINK to another TNE, which is connected to another stack of O-RAN components (CU, DU). Below the XHAUL LINK, two boards (Board 1 and Board 2) are shown, connected to the TNEs. A Traffic generator/Analyser is connected to the boards via 1/10/25/100 GbE links. The diagram also shows connections to NGC/EPC (Network Core) and various network interfaces (1/10/25/100 GbE)." data-bbox="422 750 1173 1220" src="77b81b63aaf6597a4b7098c9d10c686e_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>1. Define a native IPv6 connectivity in TNEs.</li> <li>2. Perform connectivity between O-RU, O-DU and O-CU natively in IPv6 (if eCPRI is directly encapsulated in Eth, then this would apply solely to midhaul traffic).</li> <li>3. The test should be at least 120 secs in duration.</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Validate IPv6 connectivity</li> <li>2. Make measure and report traffic passing rate for each size of frames in included table, comparing with the scenario of native IPv4 connectivity.</li> </ol> | | | +| <b>Test Configuration</b> | | | | +| <b>Pass/Fail Criteria:</b> | Compare the results obtained for latency, jitter and throughput for the scenarios with and without background traffic. | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | The output of the tests will be the set of tables defined for latency, jitter and throughput, not repeated here for simplicity. | | | + +### 8.4.9 Support of IPv6 connectivity in an IPv4 network (dual stack) + +To discuss if tunneling or translation methods should be detailed as separated tests or included here + +| Test ID | Ethernet.DUAL.01 | Classification | Functionality | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Support of IPv6 connectivity in an IPv4 network | | | +| Test Objective: | <p>The aim of the test is to check the impacts due to the usage of IPv6 in O-RU, O-DU and O-CU when the underlying network is IPv4-based. IPv6 support is optional in ORAN-WG4.CUS.</p> <p>This is a functional test but can also have performance implications to be validates by collecting statistics of latency, jitter and throughput.</p> | | | +| Pre-Req | Proper dual stack support (IPv4 and IPv6) by the TNEs | | | +| Test Topology: | <img alt="Test Topology Diagram: A diagram showing two TNEs connected via an XHAUL LINK. Each TNE contains a stack of CU, DU, and RU. Below the stack are Board 1 and Board 2. A yellow line connects Board 1 of the left TNE to Board 1 of the right TNE. A green line connects Board 2 of the left TNE to Board 2 of the right TNE. A Traffic generator/Analyser is connected to both Board 1 and Board 2 of both TNEs. Labels include '1 / 10 / 25 / 100 GbE' and 'NGC/EPC'." data-bbox="422 750 1165 1220" src="25e96b2765418f1b55faed3e8825f30a_img.jpg"/> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <p><b>Test Procedure:</b></p> <ol style="list-style-type: none"> <li>1. Define a native IPv4 connectivity in TNEs.</li> <li>2. Perform connectivity between O-RU, O-DU and O-CU natively in IPv6 (if eCPRI is directly encapsulated in Eth, then this would apply solely to midhaul traffic).</li> <li>3. The test should be at least 120 secs in duration.</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Validate IPv6 connectivity with dual stack capabilities in the TNEs.</li> <li>2. Make measure and report traffic passing rate for each size of frames in included table, comparing with the scenario of native IPv4 connectivity.</li> </ol> | | | +| Test Configuration | To be defined the mechanisms for IPv6 to IPv4 consideration | | | +| Pass/Fail Criteria: | Compare the results obtained for latency, jitter and throughput for the scenarios with and without background traffic. | | | +| Results | [ X ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| Test Output | The output of the tests will be the set of tables defined for latency, jitter and throughput, not repeated here for simplicity. | | | + +### 8.4.10 Support of IPv4 connectivity in an IPv6 network (dual stack) + +To discuss if tunneling or translation methods should be detailed as separated tests or included here. + +| Test ID | Ethernet.DUAL.02 | Classification | Functionality | +|---------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Support of IPv4 connectivity in an IPv6 network | | | +| Test Objective: | <p>The aim of the test is to check the impacts due to the usage of IPv4 in O-RU, O-DU and O-CU when the underlying network is IPv6-based.</p> <p>This is a functional test but can have also performance implications to be validated by collecting statistics of latency, jitter and throughput.</p> | | | +| Pre-Req | Proper dual stack support (IPv4 and IPv6) by the TNEs | | | +| Test Topology: | <img alt="Test Topology Diagram: A diagram showing two TNEs connected via an XHAUL LINK. Each TNE contains a stack of CU, DU, and RU. Below the stack are two boards, Board 1 and Board 2. A Traffic generator/Analyser is connected to the boards via green lines labeled '1 / 10 / 25 / 100 GbE'." data-bbox="427 824 1168 1299" src="884b5829d73878527df431d14696730d_img.jpg"/> | | | +| Procedure: | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Define a native IPv4 connectivity in TNEs.</li> <li>2. Perform connectivity between O-RU, O-DU and O-CU natively in IPv6 (if eCPRI is directly encapsulated in Eth, then this would apply solely to midhaul traffic).</li> <li>3. The test should be at least 120 secs in duration.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Validate IPv6 connectivity with dual stack capabilities in the TNEs.</li> <li>2. Make measure and report traffic passing rate for each size of frames in included table, comparing with the scenario of native IPv4 connectivity.</li> </ol> | | | +| Test Configuration | To be defined the mechanisms for IPv6 to IPv4 consideration | | | +| Pass/Fail Criteria: | Compare the results obtained for latency, jitter and throughput for the scenarios with and without background traffic. | | | +| Results | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| Test Output | The output of the tests will be the set of tables defined for latency, jitter and throughput, not repeated here for simplicity. | | | + +### 8.4.11 Test for in-band / out-band management + +| | | | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Ethernet.IOUT.01 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Validation of in-band /out-band management of TNEs | | | +| <b>Test Objective:</b> | The aim of the test is to validate the in-band management of the device. TNEs addressing fronthaul / midhaul connectivity will usually lack of dedicated out-band management network. | | | +| <b>Pre-Req</b> | Configure in-band management plane connection. According to O-RAN.WG4.CUS specification, the management plane Cos is 2, and the DSCP code is AF2x.<br><br>Introduce background traffic of higher and lower priority and validate management actions on the device. | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: Two TNEs (TNE and TNE) are connected via an XHAUL LINK. Each TNE contains a stack of CU, DU, and RU. Below the stack are Board 1 and Board 2. A Traffic generator/Analyser is connected to both Board 1 and Board 2 of both TNEs. Green lines represent 1/10/25/100 GbE connections between the boards and the traffic generator/analyser." data-bbox="422 884 1173 1366" src="c2f163574be3eb460ee3eb8dad3a3249_img.jpg"/> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>Defined a proper reachability of management IP address in-band, in such a way that the management address of one TNE can be accessed through the other TNE.</li> <li>Configure background traffic (with higher and lower priorities) to compete for the network resources. Proper dimensioning can follow the scenarios described in O-RAN-WG9.Transport requirement document.</li> <li>The test should be at least 5 min in duration.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>Validate the possibility of managing the device in-band.</li> <li>Compare the responses to configuration actions between out-band and in-band management of the device.</li> </ol> | | | +| <b>Test Configuration</b> | | | | +| <b>Pass/Fail Criteria:</b> | Compare the results obtained with out-band management. | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Output</b> | The output of the tests will be the set of tables defined for latency, jitter and throughput, for each of the selected combinations of protocols and encapsulations. | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------| + +### 8.4.12 Transparency of eCPRI Ethertype + +| | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Ethernet.ETHTYPE.01 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Transparency of eCPRI ethertype | | | +| <b>Test Objective:</b> | The aim of the test is to validate that eCPRI Ethertype is passed transparently and frames with such Ethertype are not discarded | | | +| <b>Pre-Req</b> | | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A circular loop between a circle labeled 'TNE' and a rectangle labeled 'Tester'. An arrow points from the Tester to TNE, and another arrow points from TNE back to the Tester." data-bbox="667 869 1177 1326" src="b06e9e3bca7dc02d69312e98185e7672_img.jpg"/> <pre> graph LR Tester[Tester] --> TNE((TNE)) TNE --> Tester </pre> | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p>To check if different encapsulations can have any impact.</p> <p>To check if the support of IEEE 1914 ethertype is also required.</p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. The tester will inject eCPRI frames with the corresponding eCPRI Ethertype.</li> <li>2. The test should be at least 120 secs in duration.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Validate that eCPRI Ethertype is transparently supported</li> </ol> | | | +| <b>Test Configuration</b> | | | | +| <b>Pass/Fail Criteria:</b> | No loss frame | | | +| <b>Results</b> | [ ] Pass [ ] Pass w/X [ ] Dropped [ ] Blocked [ ] Failed | | | +| <b>Test Output</b> | No losses. | | | + +### 8.4.13 Recovery times + +| | | | | +|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------| +| <b>Test ID</b> | Ethernet.REC.01 | <b>Classification</b> | Functionality | +| <b>Test Title</b> | Service restoration | | | +| <b>Test Objective:</b> | The aim of the test is to measure the time for service restoration in the event of link failure | | | +| <b>Pre-Req</b> | Configure to links between TNEs.<br>Configure the proper encapsulations / protocol support for the service. | | | +| <b>Test Topology:</b> | | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <p><b><u>Test Procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Configure the service emulating fronthaul / midhaul / backhaul connection.</li> <li>2. Inject traffic.</li> <li>3. Shut down the link from where the traffic is passing.</li> <li>4. Measure the frame losses and the time to recover.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Validate the time for service recovery</li> </ol> | | | +| <b>Test Configuration</b> | <img alt="Test Configuration Diagram: A diagram showing two TNEs (Test Network Elements) connected by two links, Link 1 and Link 2. A Tester is connected to both TNEs via lines that loop around the bottom. The Tester is represented by a rectangle with the word 'Tester' inside." data-bbox="414 1232 1085 1702" src="d1d81347d5a3218401c0e51cc864e33c_img.jpg"/> | | | +| <b>Pass/Fail Criteria:</b> | Recovery time | | | +| <b>Results</b> | <input type="checkbox"/> Pass <input type="checkbox"/> Pass w/X <input type="checkbox"/> Dropped <input type="checkbox"/> Blocked <input type="checkbox"/> Failed | | | +| <b>Test Output</b> | Recovery time | | | + +### 8.4.14 Test of Buffer Sizing + +| Test ID | Ethernet.BUF.01 | Classification | Functionality | +|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Buffer Sizing | | | +| Test Objective: | <p>This test is For Further Study.</p> <p>It is meant for midhaul and backhaul cases.</p> <p>The aim of the test is to check the buffering capacity at which the TNE receives and forwards the traffic which the amount of the ingress traffic is greater than the throughput of the egress interface with no frame loss with Xhaul (Midhaul/ Backhaul) link.</p> | | | +| Pre-Req | N/A | | | +| Test Topology: | <img alt="Test Topology Diagram: A central cloud labeled 'Xhaul Transport Network' connects two 'TNE' (Transport Network Element) blocks. Each TNE is connected to a stack of three blue boxes: 'CU' (Control Unit), 'DU' (Distributed Unit), and 'RU' (Radio Unit). The left stack is labeled 'UNI' and the right stack is labeled '5GC/EPC'. A 'Traffic generator' block at the bottom sends traffic to both TNEs. Arrows indicate traffic flow from the generator to the TNEs and then to the CU/DU/RU stacks. The connection between the TNEs and the stacks is labeled 'UNI/NNI'." data-bbox="416 913 1396 1391" src="dc614d6176386a794f6cc11a39aad90d_img.jpg"/> | | | +| Test Configuration | <ol style="list-style-type: none"> <li>There could be one TNE or two or more TNEs. Service is configured in one TNE /among TNEs to make traffic be switched.</li> <li>The buffer size parameter of shaping function is not defined but no frame loss is desired.</li> </ol> | | | +| Pass/Fail Criteria: | | | | +| Results | <input checked="" type="checkbox"/> Pass <input type="checkbox"/> Pass w/X <input type="checkbox"/> Dropped <input type="checkbox"/> Blocked <input type="checkbox"/> Failed | | | + +## 8.5 Fronthaul Services Redundancy and High Availability + +This section covers the Fronthaul redundancy scenarios where the CSR (on the O-RU side) is connected to 2 (or more) HSR's that provide connectivity to the O-DU. EVPN VPWS is used between the two sites in a redundant configuration as defined in the O-RAN Xhaul Packet switched Network Architecture. All test cases in this section correspond to section 13 of the Packet Switched Specification. + +In the following test cases a Traffic Gen (also referred to as an O-DU or O-RU simulator) is used to generate and analyze test traffic towards O-RU or O-DU. It is connected directly to a CSR or an HSR port that usually connects to an O-RU or an O-DU. For illustration purposes the O-RU or O-DU are left in the test setup diagrams, although they are not needed for the test application. + +### 8.5.1 Multi-Home Active/Active Fronthaul Redundancy + +| Test ID | Ethernet.HA.01 | Classification | Redundancy & High Availability | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|--------------------------------| +| Test Title | Active-active Fronthaul service redundancy | | | +| Test Objective: | Verify O-RU – O-DU redundancy using Active-Active EVPN VPWS services | | | +| Pre-Req | SR-MPLS and/or SRv6 baseline configuration on CSR, HSR and any other Fronthaul routers<br>Timing and syn configuration through FH network for RAN Nodes to sync | | | +| Test Topology: | <img alt="Test Topology Diagram: A network diagram showing an O-RU connected to a CSR via a 7.2x eCPRI link. The CSR is connected to two HSRs (HSR1 and HSR2) via EVPN VPWS links. Both HSRs are connected to an O-DU via 7.2x eCPRI links. A Traffic Gen is connected to the CSR and the O-DU." data-bbox="414 1232 1332 1444" src="332615ee8041c456b47322dfe7300316_img.jpg"/> | | | +| Test Configuration | <ol style="list-style-type: none"> <li>1. Connect O-RU to the UNI of the CSR and dual-home O-DU to multiple HSRs.</li> <li>2. Configure EVPN VPWS Active -Active between CSR and HSR as shown in test topology.</li> <li>3. O-DU should support terminating both port from HSRs on a single logical BD</li> </ol> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Verify O-RU and O-DU are up and communicating.</li> <li>2. Start bi-directional traffic between the RAN nodes, verify traffic is being received on either ends.</li> <li>3. Fail 1 of the two Active-Active EVPN VPWS services by either: <ol style="list-style-type: none"> <li>a. Powering off HSR-1, or</li> <li>b. Disconnect the UNI from HSR-1 to O-DU</li> </ol> </li> <li>4. Verify all traffic is converged on the other EVPN VPWS circuit.</li> <li>5. Wait for traffic to regain pre-failure rates, then recover the failure, by powering on the HSR-1 or reconnecting UNI on HSR-1.</li> </ol> | | | + +| | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | 6. Wait for EVPN services to recover to pre-failure state with Active-Active configuration | +| <b>Pass/Fail Criteria:</b> | <p><b>During Failure:</b></p> <ol style="list-style-type: none"> <li>1. No application layer connectivity loss between O-RU and O-DU (O-RU should not reboot)</li> <li>2. Document Failure convergence time. Ensure the convergence time is within Operator defined upper limits.</li> <li>3. All traffic converges on the Active VPWS link with 0 Packet loss post convergence.</li> </ol> <p><b>During Recovery</b></p> <ol style="list-style-type: none"> <li>4. No application layer connectivity loss between O-RU and O-DU (O-RU should not reboot)</li> <li>5. Document recovery convergence time. Ensure the convergence time is within Operator defined upper limits.</li> <li>6. All traffic reverts to using Active-Active VPWS configuration with 0 Packet loss post convergence.</li> </ol> | +| <b>Test Output</b> | Capture syslogs and any error messages received during failure and recovery.<br>Document failure and recovery convergence times | + +1 + +2 + +3 + +### 8.5.2 Multi-Home Single-Active Bundle Fronthaul Redundancy + +| | | | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------------------| +| <b>Test ID</b> | Ethernet.HA.02 | <b>Classification</b> | Redundancy & High Availability | +| <b>Test Title</b> | Active-active Fronthaul service redundancy | | | +| <b>Test Objective:</b> | 1. Verify O-RU – O-DU redundancy using Single-Active EVPN VPWS services | | | +| <b>Pre-Req</b> | SR-MPLS and/or SRv6 baseline configuration on CSR, HSR and any other Fronthaul routers<br><br>Timing and syn configuration through FH network for RAN Nodes to sync | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A network diagram showing an O-RU connected to a CSR (Central Site Router) via a 7.2x eCPRI link. The CSR is connected to two HSRs (Home Site Routers), HSR1 and HSR2, via EVPN VPWS links. HSR1 and HSR2 are connected to an O-DU (On-Demand Unit) via 7.2x eCPRI links. A Traffic Gen (Traffic Generator) is connected to the O-RU and O-DU. A red cloud icon represents the EVPN VPWS service between CSR and HSRs." data-bbox="413 1563 1340 1771" src="5d194147ee7707a26492d37b08d36044_img.jpg"/> | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Connect O-RU to the UNI of the CSR and dual-home O-DU to multiple HSRs.</li> <li>2. Configure EVPN VPWS Single-Active between CSR and HSR as shown in test topology.</li> <li>3. O-DU should support terminating both port from HSRs on a single logical BD</li> </ol> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Verify O-RU and O-DU are up and communicating.</li> </ol> | | | + +| | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>Start bi-directional traffic between the RAN nodes, verify traffic is being received on either ends using active EVPN VPWS only, in this case through HSR1.</li> <li>Fail the Active EVPN VPWS services by either: <ol style="list-style-type: none"> <li>Powering off HSR-1, or</li> <li>Disconnect the UNI from HSR-1 to O-DU</li> </ol> </li> <li>Verify all traffic is converged on the other EVPN VPWS circuit through HSR2.</li> <li>After full traffic convergence, recover the failure, by powering on the HSR-1 or reconnecting UNI on HSR-1.</li> <li>Wait for EVPN services to recover to pre-failure state with Single-Active configuration</li> </ol> | +| <b>Pass/Fail Criteria:</b> | <p><b>During Failure:</b></p> <ol style="list-style-type: none"> <li>No application layer connectivity loss between O-RU and O-DU (O-RU should not reboot)</li> <li>Document Failure convergence time. Ensure the convergence time is within Operator defined upper limits.</li> <li>All traffic converges on the backup VPWS link, that now becomes active, with 0 Packet loss post convergence.</li> </ol> <p><b>During Recovery</b></p> <ol style="list-style-type: none"> <li>No application layer connectivity loss between O-RU and O-DU (O-RU should not reboot)</li> <li>Document recovery convergence time, if any. Ensure the convergence time is within Operator defined upper limits.</li> <li>All traffic revert to pre-failure state, Single-Active VPWS configuration with 0 Packet loss post convergence.</li> </ol> | +| <b>Test Output</b> | <p>Capture syslogs and any error messages received during failure and recover.</p> <p>Document failure and recovery convergence times</p> | + +1 + +2 + +### 8.5.3 Multi-Home Single-Active Standalone Fronthaul Redundancy + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------------------| +| <b>Test ID</b> | Ethernet.HA.03 | <b>Classification</b> | Redundancy & High Availability | +| <b>Test Title</b> | Active-active Fronthaul service redundancy | | | +| <b>Test Objective:</b> | 2. Verify O-RU – O-DU redundancy using Single-Active EVPN VPWS services | | | +| <b>Pre-Req</b> | SR-MPLS and/or SRv6 baseline configuration on CSR, HSR and any other Fronthaul routers<br><br>Timing and syn configuration through FH network for RAN Nodes to sync | | | +| <b>Test Topology:</b> | <img alt="Network topology diagram for Multi-Home Single-Active Standalone Fronthaul Redundancy. The diagram shows an O-RU connected to a CSR (Central Site Router) via a 7.2x eCPRI link. The CSR is connected to two HSRs (Home Site Routers), HSR1 and HSR2, via a red cloud representing the EVPN VPWS. HSR1 is connected to an O-DU via a 7.2x eCPRI link. A Traffic Gen is connected to both the O-RU and the O-DU. A dashed line indicates a backup path from the CSR to HSR2." data-bbox="411 1809 1374 2027" src="3ae95fca46a8ce5dc6b4ad13ce042f6f_img.jpg"/> | | | + +| | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Connect O-RU to the UNI of the CSR and dual-home O-DU to multiple HSRs.</li> <li>2. Configure EVPN VPWS Single-Active between CSR and HSR as shown in test topology.</li> <li>3. O-DU should support terminating both port from HSRs on a single logical BD.</li> <li>4. UNI's from HSR pair are not part of the port channel in this scenario</li> </ol> | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Verify O-RU and O-DU are up and communicating.</li> <li>2. Start bi-directional traffic between the RAN nodes, verify traffic is being received on either ends using active EVPN VPWS only, in this case through HSR1.</li> <li>3. Fail the Active EVPN VPWS services by either: <ol style="list-style-type: none"> <li>a. Powering off HSR-1, or</li> <li>b. Disconnect the UNI from HSR-1 to O-DU</li> </ol> </li> <li>4. Verify all traffic is converged on the other EVPN VPWS circuit through HSR2.</li> <li>5. After full traffic convergence, recover the failure, by powering on the HSR-1 or reconnecting UNI on HSR-1.</li> <li>6. Wait for EVPN services to recover to pre-failure state with Single-Active configuration</li> </ol> | +| <b>Pass/Fail Criteria:</b> | <p><b>During Failure:</b></p> <ol style="list-style-type: none"> <li>1. No application layer connectivity loss between O-RU and O-DU (O-RU should not reboot)</li> <li>2. Document Failure convergence time. Ensure the convergence time is within Operator defined upper limits.</li> <li>3. All traffic converges on the backup VPWS link, that now becomes active, with 0 Packet loss post convergence.</li> </ol> <p><b>During Recovery</b></p> <ol style="list-style-type: none"> <li>4. No application layer connectivity loss between O-RU and O-DU (O-RU should not reboot)</li> <li>5. Document recovery convergence time, if any. Ensure the convergence time is within Operator defined upper limits.</li> <li>6. All traffic revert to pre-failure state, Single-Active VPWS configuration with 0 Packet loss post convergence.</li> </ol> | +| <b>Test Output</b> | <p>Capture syslogs and any error messages received during failure and recover.</p> <p>Document failure and recovery convergence times</p> | + +### 8.5.4 Multi-Home Single-Active Standalone, Fronthaul Redundancy, no BD on O-DU + +| | | | | +|------------------------|---------------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------------------| +| <b>Test ID</b> | Ethernet.HA.04 | <b>Classification</b> | Redundancy & High Availability | +| <b>Test Title</b> | Active-active Fronthaul service redundancy | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify O-RU – O-DU redundancy using Single-Active EVPN VPWS services</li> </ol> | | | + +| | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Pre-Req</b> | <p>SR-MPLS and/or SRv6 baseline configuration on CSR, HSR and any other Fronthaul routers</p> <p>Timing and syn configuration through FH network for RAN Nodes to sync</p> | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A network diagram showing the test setup. An 'Orchestration/Mgmt System' is connected to an 'O-RU' and an 'O-DU'. The 'O-RU' is connected to a 'CSR' (Central Site Router) via a '7.2x eCPRI' link. The 'CSR' is connected to two 'HSR' (Home Site Router) nodes, 'HSR1' and 'HSR2', via 'EVPN VPWS' links. The 'O-DU' is connected to both 'HSR1' and 'HSR2' via '7.2x eCPRI' links. A 'Traffic Gen' (Traffic Generator) is connected to both the 'O-RU' and the 'O-DU'." data-bbox="416 383 1385 734" src="2346f80f0aa7633e2988b39e02263ad5_img.jpg"/> | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Connect O-RU to the UNI of the CSR and dual-home O-DU to multiple HSRs.</li> <li>2. Configure EVPN VPWS Single-Active between CSR and HSR as shown in test topology.</li> <li>3. In this case, O-DU terminates both port from HSRs on separate interface each with its own MAC address, instead of a single MAC address using logical BD.</li> <li>4. UNI's from HSR pair are not part of the port channel in this scenario</li> </ol> | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Verify O-RU and O-DU are up and communicating.</li> <li>2. Start bi-directional traffic between the RAN nodes, verify traffic is being received on either end using active EVPN VPWS only, in this case through HSR1.</li> <li>3. Fail the Active EVPN VPWS service by either: <ol style="list-style-type: none"> <li>a. Powering off HSR-1, or</li> <li>b. Disconnect the UNI from HSR-1 to O-DU</li> </ol> </li> <li>4. Upon detection of failure, the orchestration system should change the O-RU configuration to reflect the new MAC address to allow O-RU to communicate with the DU using new MAC.</li> <li>5. Verify all traffic is converged on the other EVPN VPWS circuit through HSR2.</li> <li>6. After full traffic convergence, recover the failure, by powering on the HSR-1 or reconnecting UNI on HSR-1.</li> <li>7. Wait for EVPN services to recover to pre-failure state with Single-Active configuration</li> </ol> | +| <b>Pass/Fail Criteria:</b> | <p><b>During Failure:</b></p> <ol style="list-style-type: none"> <li>1. Successful O-RU re-configuration. O-RU behavior on reconfiguration will depend upon RU vendor implementation.</li> <li>2. Document Failure convergence time. Evaluate whether the convergence time is in-line with Operator expectations. The convergence will be higher as O-RU reconfiguration will have to take place.</li> <li>3. All traffic converges on the backup VPWS link, that now becomes active, with 0 Packet loss post convergence.</li> </ol> <p><b>During Recovery</b></p> <ol style="list-style-type: none"> <li>4. No application layer connectivity loss between O-RU and O-DU (O-RU should not reboot)</li> <li>5. Document recovery convergence time, if any</li> </ol> | + +| | | +|--------------------|--------------------------------------------------------------------------------------------------------------------------------| +| | 6. All traffic reverts to pre-failure state, Single-Active VPWS configuration with 0 Packet loss post convergence. | +| <b>Test Output</b> | Capture syslogs and any error messages received during failure and recover.<br>Document failure and recovery convergence times | + +### 8.5.5 Transport network Redundancy + +| | | | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------------------| +| <b>Test ID</b> | Ethernet.HA.05 | <b>Classification</b> | Redundancy & High Availability | +| <b>Test Title</b> | Transport network path redundancy | | | +| <b>Test Objective:</b> | 1. Verify traffic convergence following a link/node failure in FH Network comprising redundant paths(s) | | | +| <b>Pre-Req</b> | SR-MPLS and/or SRv6 baseline configuration on CSR, HSR and any other Fronthaul routers<br><br>Optional Timing and sync configuration through FH network for RAN Nodes if actual O-RU and O-DU are used instead of O-RU and O-DU simulators<br><br>Configure Topology Independent Loop Free Alternate (TI-LFA) in the FH network | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A network diagram showing an O-RU connected to a CSR (Core Site Router) via a 7.2x eCPRI link. The CSR is connected to an HSR (Home Subscriber Router) via a red cloud representing a redundant path. The HSR is connected to an O-DU via a 7.2x eCPRI link. A Traffic Gen (Traffic Generator) is connected to both the O-RU and O-DU." data-bbox="413 1265 1324 1489" src="0214fd4a428b1e4b3ab647d4fc8e18e3_img.jpg"/> | | | +| <b>Test Configuration</b> | 1. Connect O-RU or O-RU simulator to the UNI of the CSR and O-DU or O-DU simulator to the HSR.<br>2. Configure L2VPN or EVPN VPWS Service between CSR and HSR as shown in test topology.<br>3. Configure L3VPN services between CSR and HSR for M-Plane<br>4. Verify TI-LFA backup path is programmed in the forwarding table for all services | | | +| <b>Procedure:</b> | 1. Verify O-RU and O-DU are up and communicating. If actual O-RU and O-DU are used<br>2. Start bi-directional traffic between the RAN nodes for both L2VPN/EVPN and L3VPN services, verify traffic is being received on either end .<br>3. Fail the IGP best path link from CSR to HSR, through which the traffic is being forwarded. Types of failure may include, but not limited:<br>a. Physical link failure on the CSR or HSR' directly connected interface,<br>b. A link failure on intermediary nodes along the traffic path, or<br>c. A node failure on intermediary node along the traffic path | | | + +| | | +|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>Verify Upon detection of failure, traffic convergences over the backup path for all services.</li> <li>After full traffic convergence, gather data and recover the failure, by reconnecting the failed link.</li> <li>Ensure all services recover to pre-failure state with Single-Active configuration</li> </ol> | +| <b>Pass/Fail Criteria:</b> | <p><b>During Failure:</b></p> <ol style="list-style-type: none"> <li>Document the failure impact on O-RU and O-DU, including whether there is any application layer connectivity loss between O-RU and O-DU or if O-RU reboots during the process.</li> <li>Successful traffic convergence over backup path for all services.</li> <li>Document Failure convergence time. Evaluate whether the convergence time is in-line with Operator expectations.</li> <li>No packet loss for any service once all traffic is converged.</li> </ol> <p><b>During Recovery</b></p> <ol style="list-style-type: none"> <li>Document the recovery impact on O-RU and O-DU, including whether there is any application layer connectivity loss between O-RU and O-DU or if O-RU reboots during the process.</li> <li>Document recovery convergence time if any</li> <li>All traffic reverts to pre-failure state with 0 Packet loss post convergence.</li> </ol> | +| <b>Test Output</b> | <p>Capture syslogs and any error messages received during failure and recover.</p> <p>Document failure and recovery convergence times</p> | + +## 8.6 Legacy Fronthaul and C-RAN Coexistence Verification + +This section covers the scenarios where an operator may have both 4G and 5G Fronthaul networks using C-RAN. In those cases operator may need to have traditional CPRI and 7-2x traffic coexisting on the same Packetized fronthaul requiring the CPRI traffic converted to packet using IEEE 1914-3 ROE specification as described in O-RAN Xhaul Packet Switched network architecture. Following test cases could be used to support and validate this scenario. + +### 8.6.1 Legacy CPRI with RoE Type 0 Coexistence with 7-2x eCPRI + +| Test ID | Ethernet.CPRI.01 | Classification | Functionality | +|---------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| Test Title | Coexistence and transport of Legacy CPRI over Packetized Fronthaul using IEEE 1914.3 ROE Structure agnostic Type 0 encapsulation | | | +| Test Objective: | <ol style="list-style-type: none"> <li>2. Verify that Legacy CPRI and O-RAN 7-2x traffic can coexist on Packet Fronthaul.</li> <li>3. Verify that CSR and HSR can use ROE mapper/demapper functions to convert CPRI into Packet and vice versa</li> </ol> | | | +| Pre-Req | SR-MPLS and/or SRv6 baseline configuration on CSR, HSR and any other Fronthaul routers<br>Timing and syn configuration through FH network if RAN Nodes are used, not required if test equipment or CPRI/7-2x simulator is used | | | +| Test Topology: | <img alt="Test Topology Diagram: A network diagram showing the test setup. On the left is a box labeled 'O-RU or Tester'. On the right is a box labeled 'O-DU/BBU or Tester'. Between them are two routers, 'CSR' (Control Service Router) and 'HSR' (Host Service Router), connected by a cloud. The CSR and HSR are connected via 'L2/EVPN VPWS' links. The CSR has a 'ROE' (Remote Open Edge) port connected to the O-RU/Tester. The HSR has a 'ROE' port connected to the O-DU/BBU/Tester. Traffic flows are indicated: '7.2x eCPRI' (green line) and 'CPRI (for LTE)' (blue line) between the O-RU/Tester and CSR, and between the HSR and O-DU/BBU/Tester. A red cloud connects the CSR and HSR." data-bbox="416 719 1393 869" src="ba07a2e219b5e19b46539e73a6d7d4eb_img.jpg"/> | | | +| Test Configuration | <ol style="list-style-type: none"> <li>1. O-RU and O-DU receives CPRI and 7-2x traffic on its UNI through tester or actual RAN Nodes.</li> <li>2. Interface speed on the uplink must be capable of transporting combine CPRI and 7-2X traffic.</li> <li>3. IEEE 1914.3 ROE Structure Agnostic Type 0 configuration on UNI at CSR and HSR</li> </ol> | | | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect 5G O-RU and O-DU to appropriate ethernet ports on CSR and HSR.</li> <li>2. Simultaneously, connect 4G RU and corresponding BBU to CPRI port on CSR and HSR.</li> <li>3. Configure EVPN VPWS circuits for each of the two connections between CSR and HSR.</li> <li>4. Bi-directional traffic should be sent on both the Ethernet (7-2x connected) port and ROE-enabled (CPRI facing) ports.</li> <li>5. Test should be repeated with SR-MPLS and/or SRv6 control planes depending on FH transport technology used, in accordance with the O-RAN Xhaul packet switched document.</li> <li>6. Test could be repeated for various CPRI rate options (typical are option 3 – 8, but others could be tested as well)</li> </ol> | | | +| Pass/Fail Criteria: | Successful Transport of both traffic types with 0 packet loss, within FH latency budget:<br>Correlation of counters on both CSR and HSR for:<br>7-2x Traffic: Interface counters, EVPN VPWS counters, Bridge-domain or others as implemented by the TNE vendor<br>CPRI Traffic: Two set of measurements/correlation should be used for CPRI traffic: <ol style="list-style-type: none"> <li>1. Hyperframe counters on Test equipment should match on both sides.</li> <li>2. ROE Mapper/Demapper Counters on CSR/HSR and CPRI controller should match on both side.</li> </ol> | | | + +| | | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | 3. EVPN VPWS services counters, others as implemented by the TNE vendor | +| <b>Test Output</b> | <p>Capture any data w.r.t:</p> <p>Transport underlay: SRv6 or SR-MPLS control plane, routing (ISIS/OSPF) adjacencies, EVPN VPWS service verification (PW is up on both sides),</p> <p>CPRI Transport: CPRI controller information, ROE Mapper/Demapper function verification,</p> <p>Traffic Forwarding: Interface forwarding on CPRI and 7-2x UNI, EVPN service and CPRI controller.</p> <p>Document data rates comparing CPRI with packet data after ROE Structure agnostic Type 0 mapping for legacy traffic.</p> | + +1 + +2 + +### 8.6.2 Legacy CPRI with RoE Type 1 Coexistence with 7-2x eCPRI + +4 + +| Test ID | Ethernet.CPRI.02 | Classification | Functionality | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------| +| <b>Test Title</b> | Coexistence and transport of Legacy CPRI over Packetized Fronthaul using IEEE 1914.3 ROE Structure agnostic <b>Type 1</b> encapsulation | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify that Legacy CPRI and O-RAN 7-2x traffic can coexist on Packet Fronthaul.</li> <li>2. Verify that CSR and HSR can use ROE Mapper/Demapper functions to convert CPRI into Packet using Structure agnostic Type 1 function and vice versa</li> </ol> | | | +| <b>Pre-Req</b> | <p>SR-MPLS and/or SRv6 baseline configuration on CSR, HSR and any other Fronthaul routers</p> <p>Timing and syn configuration through FH network if RAN Nodes are used, not required if test equipment or CPRI/7-2x simulator is used</p> | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A network diagram showing the coexistence of Legacy CPRI and 7-2x eCPRI traffic. On the left, 'O-RU or Tester' connects to a 'CSR' (Control Service Router) via '7.2x eCPRI' (green line) and 'CPRI (for LTE)' (blue line). The CSR connects to an 'HSR' (Host Service Router) via a cloud network. The HSR connects to 'O-DU/BBU or Tester' via '7.2x eCPRI' (green line) and 'CPRI (for LTE)' (blue line). Both CSR and HSR have 'ROE' (Router Over Ethernet) blocks. The cloud network contains two layers: 'L2/EVPN VPWS' and 'L2/EVPN VPWS'." data-bbox="414 1478 1388 1635" src="771f139f2283195791994107a5e1e6db_img.jpg"/> | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. O-RU and O-DU receives CPRI and 7-2x traffic on its UNI through tester or actual RAN Nodes.</li> <li>2. Interface speed on the uplink must be capable of transporting combine CPRI and 7-2X traffic.</li> <li>3. IEEE 1914.3 ROE Structure Agnostic <b>Type 1</b> configuration on UNI at CSR and HSR</li> </ol> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect 5G O-RU and O-DU to appropriate ethernet ports on CSR and HSR.</li> <li>2. Simultaneously, connect 4G RU and corresponding BBU to CPRI port on CSR and HSR.</li> </ol> | | | + +| | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>3. Configure EVPN VPWS circuits for each of the two connections between CSR and HSR.</li> <li>4. Bi-directional traffic should be sent on both the Ethernet (7-2x connected) port and ROE-enabled (CPRI facing) ports.</li> <li>5. Test should be repeated with SR-MPLS and/or SRv6 control planes depending on FH transport technology used, in accordance with the O-RAN Xhaul packet switched document.</li> <li>6. Test could be repeated for various CPRI rate options (typical are option 3 – 7, but others could be tested as well)</li> </ol> | +| <b>Pass/Fail Criteria:</b> | <p>Successful Transport of both traffic types with 0 packet loss</p> <p>Correlation of counters on both CSR and HSR for:</p> <p>7-2x Traffic: Interface counters, EVPN VPWS counters, Bridge-domain or others as implemented by the TNE vendor</p> <p>CPRI Traffic: ROE Mapper/Demapper Counters, CPRI controller counters, Interface, EVPN VPWS services counters, others as implemented by the TNE vendor.</p> <p>Expected ~20% bandwidth savings from CPRI and ROE based Packet transport for CPRI Rate Options 3-7 due to 8B10B line coding removal</p> | +| <b>Test Output</b> | <p>Capture any data w.r.t:</p> <p>Transport underlay: SRv6 or SR-MPLS control plane, routing (ISIS/OSPF) adjacencies, EVPN VPWS service verification (PW is up on both sides),</p> <p>CPRI Transport: CPRI controller information, ROE Mapper/Demapper function verification,</p> <p>Traffic Forwarding: Interface forwarding on CPRI and 7-2x UNI, EVPN service and CPRI controller.</p> <p>Document data rates comparing CPRI with packet data after ROE Structure agnostic <b>Type 1</b> mapping for legacy traffic.</p> | + +1 + +2 + +3 + +4 + +# 9 Xhaul Synchronization Testing + +## 9.1 Synchronization test use cases, parameters and methodologies. + +This chapter delivers the testing methodologies, parameters and limits for PTP-based network technologies. The chapter is organized in different sections each representing a typical synchronization configuration mode. For each mode, all related metrics are identified, and limits are provided to deliver pass/fail verdicts. + +Various synchronization options have been defined in the O-RAN WG4 CUS-Plane Specification [2] (LLS-C1, LLS-C2, LLS-C3 and LLS-C4). Depending on the specific O-RAN deployment being considered, not all of them might be relevant. When testing the S-Plane, the System Integrator shall identify which of the test cases are relevant depending on the specific deployment scenarios addressed. As a general guideline the following applies: + +### 1. Direct connection between O-DU and O-RU: + +LLS-C1 is generally the main sync option to be validated. + +LLS-C4 may be considered as an alternative or as a complement to LLS-C1. + +### 2. Bridged network between O-DU and O-RU + +LLS-C2 for cases where the synchronization is delivered to the O-RU via the O-DU and over the bridged network. In this case the PRTC/PRC may be embedded in the O-DU or may be located anywhere in the network (connected via backhaul or FH transport). + +LLS-C3 for cases when the synchronization is distributed to the O-RU without involving the O-DU In this case the PRTC/PRC may be located anywhere in the network (connected via backhaul or FH transport) and may also be co-located with the O-DU. + +LLS-C4 may be considered as alternative or as a complement to LLS-C2/LLS-C3. LLS-C4 is considered for future versions of the specification. + +The Fronthaul focused tests for S-Plane for the current version of this specification covers LLS-C1, LLS-C2 and LLS-C3 using the ITU-T G.8275.1 [5] profile (Full Timing Support). Fronthaul focused tests for S-Plane for LLS-C1, LLS-C2 and LLS-C3 using the ITU-T G.8275.2 [6] profile (Partial Timing Support), and LLS-C4 are for future study. + +The test cases apply to both lab and field deployment cases. For lab cases, the type and number of inserted Transport Node Elements (TNE) will be determined by operators (or any other applicable end customer). The tests are performed at Xhaul UNI interfaces, and not between individual TNEs. The Xhaul UNI interfaces include O-RU Fronthaul UNI, O-DU Fronthaul or Midhaul UNI. + +The Test Topologies in all the test cases uses GNSS simulator to generate the GNSS signal to the network PRTC/T-GM. This high-quality reference from the simulator is used as the external reference for clock testers as well. The resultant accuracy of this method is a few nanoseconds. However, one can also use a GNSS signal feeding both the initial PRTC/T-GM in the network and the reference clock generating a 1pps/10MHz used to synchronize the clock testers for the measurements. Operator can make an allowance in this case, for all of the measurements for the accuracy of the reference. The magnitude of this allowance will depend on the specific GNSS reference in use. + +For relative time error measurements at UNI (e.g., O-RU Fronthaul UNI) this document uses the metric $\max|TE_{RL}|(1,2)$ as defined in [88], Appendix XI. Please note this metric represents an estimation and the worst-case scenario. Tests that meet (are below) the limits are seen as PASS. Tests not meeting this metric may still be acceptable. The decision is for operators to make. However, if the measurement equipment support relative time error measurement, operator can use such equipment. Refer ITU-T G.8271.1 Appendix XI for more details. + +For Frequency Limit at UNI (e.g., O-RU Fronthaul UNI) this document uses the metric defined as per WG4 section H.2 based on O-DU class for LLS-C1 and LLS-C2 configuration and based on PRTC class for LLS-C3 configuration. Applicable MTIE limit shall apply for Frequency as per WG4 specification. + +ITU-T G.8273 Annex B mentions the Phase/time clock equipment specification related measurement methods. One can refer to this section for any additional information and guideline for such measurements. + +The acceptable limits in all the below tests shall meet CUS specification worst case limits based on the maximum network size, but operator “should” apply the limits more aligned with the real tested configuration based on the network size. + +### 9.1.1 Network Time Synchronization-LLS-C1 (Option-A) configuration + +| Test ID | SYNC.TE.01 | Classification | Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------| +| Test Title | Measurement of Frequency Error, Time Error, Relative Time Error at O-RU UNI. Configuration-LLS-C1(Option-A) (T-GM embedded in O-DU) | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| Pre-Req | ODU (Integrated T-GM) connected to PRTC/GNSS and locked to PRTC.<br>O-RU UNI is the measurement Plane | | | +| Test Topology: | <img alt="Test Topology Diagram for Network Time Synchronization-LLS-C1 (Option-A) configuration. The diagram shows a Frequency Reference connected to a GNSS Simulator. The GNSS Simulator outputs a 1PPS Ref+10MHz Ref signal to the O-DU UNI and an RF Signal to the PRTC. The PRTC outputs a 1PPS signal to the TOD, which then outputs to the O-DU T-GM. The O-DU T-GM outputs a 1PPS out signal to the O-RU UNI. Two Clock Testers are connected to the O-RU UNI. The diagram also shows time error limits: ±30-95ns for (FR2-FR1) and ±50ns for (FR1). The total time error limit is TE_L ≤ 1420ns. Specific limits for Enhanced O-RU (FR2-FR1) are Max TE_RL =60-190ns and TAE=130-260ns. For Regular O-RU (FR1), Max TE_RL =100ns and TAE=260ns." data-bbox="405 1541 1420 2033" src="94dc926f52737014cf46c0833bd36cf7_img.jpg"/> | | | + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to O-DU.</p> | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>3. G.8275.1 Full Timing Support profile.</li> </ol> | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect T-GM (O-DU) to GNSS Simulator.</li> <li>2. Configure O-DU as T-GM with G.8275.1 profile.</li> <li>3. Configure SyncE on O-DU with ESMC/eESMC as applicable.</li> <li>4. Connect Clock Tester measurement ports to O-DU TimeTransmitter ports to monitor PTP at the O-RU UNI.</li> <li>5. Establish a PTP and SyncE session to the fronthaul network.</li> </ol> <p><b><u>Verifications for Maximum Absolute Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP and SyncE session is up and running.</li> <li>2. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 UNI independently. <ol style="list-style-type: none"> <li>a. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI should be <math>\leq 1420ns</math> (For Regular RU)</li> <li>b. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI should be <math>\leq 1465ns</math> (For Enhanced RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error (NOTE1)</u></b></p> <ol style="list-style-type: none"> <li>1. Perform the time error measurements on Clock Tester at O-RU1 and O-RU2 UNI independently. Collect the data (<math>\max TE_1, \min TE_1</math>) and (<math>\max TE_2, \min TE_2</math>) for O-RU1 UNI and O-RU2 UNI respectively at least for a period of 1000sec.</li> <li>2. Estimate the Maximum Relative Time Error measurements between the two O-RU UNI ports. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 60\ (FR2)</math> (For Enhanced RU)</li> <li>b. <math>\max TE_{RL} (1,2) \leq 190ns\ (FR1)</math> (For Enhanced RU)</li> <li>c. <math>\max TE_{RL} (1,2) \leq 100ns\ (FR1)</math> (For Regular RU)</li> </ol> </li> </ol> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TE_{RL}(t)</math>, but to measure the maximum possible value it can take.</p> $\max TE_{RL} (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$ <p><b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP and SyncE session is up and running.</li> <li>2. Perform 1PPS time error measurements on Clock Tester at O-RU1 and O-RU2 UNI independently. <ol style="list-style-type: none"> <li>a. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1420ns</math> (For Regular RU)</li> <li>b. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1465ns</math> (For Enhanced RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Time Wander</u></b></p> | + +| | | | | | +|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------|-------------------|-------------------|----------------| +| 1. Verify the Time Wander using Clock tester at the O-RU UNI.<br>a. Frequency Limit is $\leq 15ppb$ (For O-DU Class-A)<br>b. Frequency Limit is $\leq 5ppb$ (For O-DU Class-B)<br>c. MTIE mask as per the limit specified.<br>NOTE1 (As per G.8271.1):<br>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. | | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For enhanced RU) | (For regular RU) | | +| | Packet $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | 1PPS $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| | Frequency Limit (For O-DU Class-A) | $\leq 15ppb$ | $\leq 15ppb$ | | +| | Frequency Limit (For O-DU Class-B) | $\leq 5ppb$ | $\leq 5ppb$ | | + +### 9.1.2 Network Time Synchronization-LLS-C1 (Option-B) configuration: + +#### Scenario-1 + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.02 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Frequency Error, Absolute Time Error, Relative Time Error at O-RU UNI. Configuration-LLS-C1(Option-B) | | | +| <b>Test Objective:</b> | 1. Verify the Maximum Absolute Packet Time Error ( $\max TE_L $ ) at O-RU UNI.<br>2. Verify the Maximum Relative Packet Time Error ( $\max TE_{RL} $ ) between two O-RU UNI ports.<br>3. Verify the Maximum Absolute 1PPS Time Error ( $\max TE_L $ ) at O-RU UNI.<br>4. Verify the Time Wander at the O-RU UNI. | | | +| <b>Pre-Req</b> | T-GM is directly connected to O-DU.<br>O-RU UNI is the measurement plane. | | | + +#### Test Topology: + +![Test Topology Diagram showing the connection between a Frequency Reference, GNSS Simulator, T-GM, O-DU, and O-RU UNI. The diagram includes timing requirements for PRTC-A, PRTC-B, ePRTC, and TE, as well as timing requirements for the Clock Tester at O-RU UNI for Enhanced and Regular O-RU.](6d940bb6c9a1ab31f74f537dc458b573_img.jpg) + +The diagram illustrates the test topology for clock testing. A Frequency Reference and GNSS Simulator provide a 1PPS Ref+10MHz Ref signal to the T-GM and O-DU. The T-GM (PRTC-A, |TE| ≤ 100ns; PRTC-B, |TE| ≤ 40ns; ePRTC, |TE| ≤ 30ns) is connected to the O-DU (T-BC/EEC/eEEC). The O-DU is connected to the O-RU UNI. The O-RU UNI contains two Clock Testers. The timing requirements for the Clock Tester at O-RU UNI are as follows: + +- For Enhanced O-RU (FR2-FR1): $\max|TE_{RL}| = 60-190\text{ns}$ at O-RU UNI, $TA_E = 130-260\text{ns}$ +- For Regular O-RU (FR1): $\max|TE_{RL}| = 100\text{ns}$ at O-RU UNI, $TA_E = 260\text{ns}$ + +Additional timing requirements shown in the diagram include: + +- ±30-95ns (FR2-FR1) +- ±50ns (FR1) +- |TE| ≤ 1420ns + +Test Topology Diagram showing the connection between a Frequency Reference, GNSS Simulator, T-GM, O-DU, and O-RU UNI. The diagram includes timing requirements for PRTC-A, PRTC-B, ePRTC, and TE, as well as timing requirements for the Clock Tester at O-RU UNI for Enhanced and Regular O-RU. + +The test topology above illustrates the placement of clock tester at measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to O-DU. + +#### Test Configuration + +1. Clock Tester at O-RU UNI receives timing input on its measurement port. +2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +3. G.8275.1 Full Timing Support profile. + +##### Procedure: + +#### Detailed Test procedure: + +1. Connect T-GM/PRTC directly to O-DU. +2. Configure O-DU as T-BC. +3. Configure G.8275.1 profile on O-DU and T-GM. +4. Configure End-to-End SyncE with ESMC/eESMC as applicable. +5. Connect tester measurement ports to O-DU TimeTransmitter ports to monitor the PTP at the O-RU1 and O-RU2 UNI. +6. Establish a PTP and SyncE session to the fronthaul network. + +#### Verifications for Maximum Absolute Packet Time Error + +7. Verify that PTP session is up and running. +8. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420\text{ns}$ (For Regular RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465\text{ns}$ (For Enhanced RU) + +##### Verifications for Maximum Relative Packet Time Error (NOTE1) + +9. Perform the time error measurements on Clock Tester at O-RU1 and O-RU2 UNI independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for O-RU1 UNI and O-RU2 UNI respectively at least for a period of 1000sec. +10. Estimate the Maximum Relative Time Error measurements between the two O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190\text{ns}$ (FR1) (For Enhanced RU) + +$$c. \max|TE_{RL}|(1,2) \leq 100ns \text{ (FR1) (For Regular RU)}$$ + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +##### **Verifications for Maximum Absolute 1PPS Time Error** + +11. Verify that PTP and SyncE session is up and running. +12. Perform 1PPS time error measurements on Clock Tester at O-RU1 and O-RU2 UNI independently. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + +##### **Verifications for Time Wander** + +13. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### **Pass/Fail Criteria:** + +Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. + +#### **Test Output** + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|-------------------|-------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| 1PPS $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| Frequency Limit (For O-DU Class-A) | $\leq 15ppb$ | $\leq 15ppb$ | | +| Frequency Limit (For O-DU Class-B) | $\leq 5ppb$ | $\leq 5ppb$ | | + +### 9.1.3 Network Time Synchronization-LLS-C1 (Option-B) configuration: + +#### Scenario-2. + +| | | | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.03 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Frequency Error, Absolute Time Error, Relative Time Error at O-RU UNI. LLS-C1(Option-B) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at O-RU UNI.</li> <li>5. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | T-GM is dual-homed to ODUs.<br>O-RU UNI is the measurement plane. | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A block diagram showing the test setup. A Frequency Reference and GNSS Simulator provide a 1PPS Ref+10MHz Ref signal to a T-GM and two O-DUs. The T-GM is connected to two O-DUs (T-BC/eEEC). The O-DUs are connected to O-RU UNI ports, which are connected to Clock Testers. The diagram includes timing constraints: PRTC-A, TE ≤100ns; PRTC-B, TE ≤40ns; ePRTC, TE ≤30ns; ±30-95ns (FR2-FR1); ±50ns (FR1); TE ≤1420ns. Performance targets are listed for Enhanced O-RU (FR2-FR1) and Regular O-RU (FR1)." data-bbox="414 772 1428 1332" src="22b4c62f1e3935cd4fd9c6d19d42d08f_img.jpg"/> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to O-DU.</p> <p>For Enhanced O-RU (FR2-FR1)<br/> <math>Max TE_{RL} =60-190ns</math> at O-RU UNI<br/> <math>TAE=130-260ns</math></p> <p><math>Max TE_L =2840ns</math> @O-RU UNI<br/> <math>TAE=3000ns</math></p> <p>For Regular O-RU (FR1)<br/> <math>Max TE_{RL} =100ns</math> at O-RU UNI<br/> <math>TAE=260ns</math></p> | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>3. G.8275.1 Full Timing Support profile as applicable.</li> </ol> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect T-GM/PRTC to both O-DUs directly.</li> <li>2. Configure O-DU as T-BC.</li> <li>3. Configure G.8275.1 profile on O-DU and T-GM.</li> <li>4. Configure End-to-End SyncE with ESMC/eESMC as applicable.</li> <li>5. Connect tester measurement ports to O-DU TimeTransmitter ports to monitor PTP at the O-RU1 and O-RU2 UNI.</li> <li>6. Establish a PTP and SyncE session to the fronthaul network.</li> </ol> <p><b>Verifications for Maximum Absolute Packet Time Error</b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP and SyncE session is up and running.</li> <li>2. Verify time error measurements using Clock Tester at O-RU UNI.</li> </ol> | | | + +- a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) +- b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the two O-RU UNI ports connected to O-DU1. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) +3. Estimate the Maximum Relative Time Error measurements between the two O-RU UNI ports connected to O-DU2. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) +4. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports connected to O-DU1 and O-DU2. + - a. $\max|TE_{RL}|(1,2) \leq 2930ns$ (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 2840ns$ (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TERL(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Perform 1PPS time error measurements on Clock Tester at O-RU1 and O-RU2 UNI independently. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + +##### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the TimeTransmitter ports of O-DU1 and O-DU2 at O-RU UNI. + - a. $\max|TE_{RL}|(1,2) \leq 2930ns$ (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 2840ns$ (For Regular RU) + +##### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + +- a. Frequency Limit is $\leq 15ppb$ (For O-DU Class-A) +- b. Frequency Limit is $\leq 5ppb$ (For O-DU Class-B) +- c. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### Pass/Fail Criteria: + +Test shall pass if the Max Absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the specified limits. + +#### Test Output + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|-----------------------------------------------------------------------------|-------------------|-------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| 1PPS $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| Frequency Limit (For O-DU Class-A) | $\leq 15ppb$ | $\leq 15ppb$ | | +| Frequency Limit (For O-DU Class-B) | $\leq 5ppb$ | $\leq 5ppb$ | | +| Relative Time Error between the O-RU UNI ports connected to O-DU1 and O-DU2 | | | | +| Packet $\max TE_{RL} $ | $\leq 2930ns$ | $\leq 2840ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 2930ns$ | $\leq 2840ns$ | | + +1 + +### 9.1.4 Network Time Synchronization-LLS-C1 (Option-C) configuration + +| Test ID | SYNC.TE.04 | Classification | Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------| +| Test Title | Measurement of Frequency Error, Maximum Absolute Time Error, Maximum Relative Time Error at O-RU UNI. LLS-C1 (Option-C) | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>\max TE_{RL} </math>) at O-RU UNI.</li> <li>5. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| Pre-Req | T-GM connected to O-DU via T-BC/T-TC chain.<br>O-RU UNI is the measurement plane. | | | + +#### Test Topology: + +![Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, T-BC/T-TC, O-DU, and O-RU with Clock Testers. The diagram includes timing constraints for various components and interfaces.](b22bbbefce73426dd810cd25259ab6bb_img.jpg) + +The diagram illustrates the test topology for clock testing. A GNSS Simulator provides a Frequency Reference and an RF Signal to a T-GM. The T-GM is connected to a T-BC/T-TC block, which in turn connects to O-DU and O-RU units. The O-DU and O-RU units are connected to Clock Testers. The diagram shows the placement of clock testers at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI are connected to the O-DUs. + +Timing constraints shown in the diagram: + +- For Enhanced O-RU (FR2-FR1): $\text{Max}|TE_{RL}| = 60-190\text{ns}$ at O-RU UNI, $TA_E = 130-260\text{ns}$ +- For Regular O-RU (FR1): $\text{Max}|TE_{RL}| = 100\text{ns}$ at O-RU UNI, $TA_E = 260\text{ns}$ +- Max $|TE_{RL}| = 2840\text{ns}$ at O-RU UNI, $TA_E = 3000\text{ns}$ +- For O-DU: $\text{PRTC-A}, |TE| \leq 100\text{ns}$ , $\text{PRTC-B}, |TE| \leq 40\text{ns}$ , $\text{ePRTC}, |TE| \leq 30\text{ns}$ +- For T-BC/T-TC: $|TE| \leq 1100\text{ns}$ +- For O-DU: $|TE| \leq 1420\text{ns}$ +- For O-RU: $\pm 30-95\text{ns}$ (FR2-FR1), $\pm 50\text{ns}$ (FR1) + +Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, T-BC/T-TC, O-DU, and O-RU with Clock Testers. The diagram includes timing constraints for various components and interfaces. + +The test topology above illustrates the placement of clock tester at measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the O-DUs. + +#### Test Configuration + +1. Clock Tester at O-RU UNI receives timing input on its measurement port. +2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +3. G.8275.1 Full Timing Support profile as applicable. + +##### Procedure: + +#### Detailed Test procedure: + +1. Connect T-GM/PRTC to O-DU via a chain of 1 or more T-BC/T-TCs. +2. Configure O-DU as T-BC. +3. Configure G.8275.1 profile on T-GM and O-DU. +4. Configure End-to-End SyncE with ESMC/eESMC as applicable. +7. Connect tester measurement ports to O-DU TimeTransmitter ports to monitor PTP at the O-RU1 and O-RU2 UNI. +5. Establish a PTP and SyncE session to the fronthaul network. + +#### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP and SyncE session is up and running. +2. Verify time error measurements using Clock Tester at O-RU UNI. + - a. $\text{max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420\text{ns}$ (For Regular RU) + - b. $\text{max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465\text{ns}$ (For Enhanced RU) + +##### Verifications for Maximum Relative Packet Time Error (NOTE1) + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\text{max}TE1, \text{min}TE1$ ) and ( $\text{max}TE2, \text{min}TE2$ ) for O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports connected to O-DU1. + - a. $\text{max}|TE_{RL}| (1,2) \leq 60\text{ns}$ (FR2) (For Enhanced RU) + - b. $\text{max}|TE_{RL}| (1,2) \leq 190\text{ns}$ (FR1) (For Enhanced RU) + - c. $\text{max}|TE_{RL}| (1,2) \leq 100\text{ns}$ (FR1) (For Regular RU) + +3. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports connected to O-DU2. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) +4. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports connected to O-DU1 and O-DU2. + - a. $\max|TE_{RL}|(1,2) \leq 2930ns$ (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 2840ns$ (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +##### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Perform 1PPS time error measurements on Clock Tester at O-RU1 and O-RU2 UNI independently. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + +##### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports connected to O-DU1 and O-DU2. + - a. $\max|TE_{RL}|(1,2) \leq 2930ns$ (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 2840ns$ (For Regular RU) + +##### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 15ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 5ppb$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the maximum relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +| | | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------|-------------------|------------------|----------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Max Absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | + + + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>3. G.8275.1 Full Timing Support profile as applicable.</li> </ol> | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect T-GM to O-DU via a chain of T-BC.</li> <li>2. Configure O-DU as T-BC and HSR as either T-BC/T-TC.</li> <li>3. Enable G.8275.1 profile on HSR and T-GM.</li> <li>4. Connect Clock tester measurement ports to CSR1 and CSR2 TimeTransmitter ports to monitor the PTP at O-RU UNI.</li> <li>5. Establish a PTP and SyncE session to the fronthaul network.</li> </ol> <p><b><u>Verifications for Maximum Absolute Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP and SyncE session is up and running.</li> <li>2. Verify time error measurements using Clock Tester at O-RU UNI. <ol style="list-style-type: none"> <li>a. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1465ns</math> (For Enhanced RU)</li> <li>b. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1420ns</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error (NOTE1)</u></b></p> <ol style="list-style-type: none"> <li>1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 UNI. Collect the data (<math>maxTE1, minTE1</math>) and (<math>maxTE2, minTE2</math>) for both the O-RU UNI at least for a period of 1000sec.</li> <li>2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li>b. <math>\max TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li>c. <math>\max TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TE_{RL}(t)</math>, but to measure the maximum possible value it can take.</p> $\max TE_{RL} (1,2) \text{ the greatest of } \begin{cases} (maxTE_L(1) - minTE_L(2)) \\ (maxTE_L(2) - minTE_L(1)) \end{cases}$ <p><b><u>Verifications for Maximum 1PPS Absolute Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP and SyncE session is up and running.</li> <li>2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. <ol style="list-style-type: none"> <li>a. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1465ns</math> (For Enhanced RU)</li> <li>b. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1420ns</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP and SyncE session is up and running.</li> <li>2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> </ol> </li> </ol> | + +b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + +c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +##### Verifications for Time Wander + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + +a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + +b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + +c. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the maximum relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +##### **Pass/Fail Criteria:** + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. + +#### **Test Output** + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|--------------------|--------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| 1PPS $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| Frequency Limit (For O-DU Class-A) | $\leq 36ppb$ | $\leq 36ppb$ | | +| Frequency Limit (For O-DU Class-B) | $\leq 32ppb$ | $\leq 32ppb$ | | + +### 9.1.6 Network Time Synchronization-LLS-C2 (Option-B) configuration: + +#### Scenario-1 + +| Test ID | SYNC.TE.06 | Classification | Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------| +| Test Title | Measurement of Frequency Error, Maximum Absolute Time Error, Maximum Relative Error at O-RU UNI. LLS-C2 (Option-B) | | | +| Test Objective: | 1. Verify the Maximum Absolute Packet Time Error ( $\max TE_L $ ) at O-RU UNI.<br>2. Verify the Maximum Relative Packet Time Error ( $\max TE_{RL} $ ) between two O-RU UNI ports.<br>3. Verify the Maximum Absolute 1PPS Time Error ( $\max TE_L $ ) at O-RU UNI.<br>4. Verify the Maximum Relative 1PPS Time Error ( $\max TE_{RL} $ ) at O-RU UNI.<br>5. Verify the Time Wander at O-RU UNI. | | | +| Pre-Req | Nearest common node for O-RU UNI is T-BC and not O-DU.<br>T-GM or PRTC connected to O-DU via chain of T-BC/T-TCs. | | | + +| | | +|-----------------------------------|----------------------------------| +| <p>Image: O-RAN Alliance Logo</p> | O-RAN.WG9.XTRP-TST.0-R004-v05.00 | +|-----------------------------------|----------------------------------| + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Topology:</b> | <p>O-RU UNI is the measurement plane.</p> <div style="text-align: center; margin: 10px 0;"> <p>Image: Test Topology Diagram</p> <p style="font-size: 11px; text-align: left; margin-top: 10px;"> The test topology above illustrates the placement of clock tester at measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSRs. </p> </div> | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>G.8275.1 Full Timing Support profile as applicable.</li> </ol> | +| <b>Procedure:</b> | <p><u><b>Detailed Test procedure:</b></u></p> <ol style="list-style-type: none"> <li>Connect T-GM to ODU via a chain of T-BC/T-TCs.</li> <li>Configure O-DU and CSR as T-BCs and HSR is configured as either T-BC or T-TC.</li> <li>Enable G.8275.1 profile on T-GM, O-DU, HSR (when acting as T-BC) and CSR.</li> <li>Connect Clock tester measurement ports to CSR1 and CSR2 TimeTransmitter ports to monitor the PTP at O-RU UNI.</li> <li>Establish PTP and SyncE session to the fronthaul network.</li> </ol> <p><u><b>Verifications for Maximum Absolute Packet Time Error</b></u></p> <ol style="list-style-type: none"> <li>Verify that PTP and SyncE session is up and running.</li> <li>Verify time error measurements using Clock Tester at O-RU UNI. <ol style="list-style-type: none"> <li><math>max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\le 1465ns</math> (For Enhanced RU)</li> <li><math>max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\le 1420ns</math> (For Regular RU)</li> </ol> </li> </ol> <p><u><b>Verifications for Maximum Relative Packet Time Error (NOTE1)</b></u></p> <ol style="list-style-type: none"> <li>Perform time error measurements on Clock Tester at O-RU1 and O-RU2 UNI. Collect the data (<math>maxTE1, minTE1</math>) and (<math>maxTE2, minTE2</math>) for both the O-RU UNI at least for a period of 1000sec.</li> <li>Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li><math>max TE_{RL} (1,2) \le 60ns</math> (FR2) (For Enhanced RU)</li> <li><math>max TE_{RL} (1,2) \le 190ns</math> (FR1) (For Enhanced RU)</li> <li><math>max TE_{RL} (1,2) \le 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> | + +| | | +|---------------------------------------------------------------------------------------------------------------------------|-----| +| © 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. | 134 | +|---------------------------------------------------------------------------------------------------------------------------|-----| + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum 1PPS Absolute Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +NOTE1: + +To measure the maximum relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +| Pass/Fail Criteria: | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | +|---------------------|----------------------------------------------------------------------------------------------------------------------------------------|--------------------|--------------------|----------------| +| Test Output | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | 1PPS $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | Frequency Limit (For O-DU Class-A) | $\leq 36ppb$ | $\leq 36ppb$ | | +| | Frequency Limit (For O-DU Class-B) | $\leq 32ppb$ | $\leq 32ppb$ | | + +## 9.1.7 Network Time Synchronization-LLS-C2 (Option-B) configuration: + +### Scenario-2 + +| Test ID | SYNC.TE.07 | Classification | Synchronization, Performance, Absolute Time Error, Relative Time Error | +|--------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------| +| Test Title | Measurement of Frequency Error, Maximum Absolute Time Error, Maximum Relative Time Error at O-RU UNI.<br>LLS-C2 (Option-B) configuration | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at O-RU UNI.</li> <li>5. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| Pre-Req | Nearest Common node for O-RU UNI is T-BC and not O-DU.<br>T-GM/PRTC connected to O-DU via chain of T-BC/T-TCs. O-DU is locked.<br>O-RU UNI is the measurement plane. | | | +| Test Topology: | <p>Image: Test Topology Diagram for Network Time Synchronization-LLS-C2 (Option-B) configuration. The diagram shows a Frequency Reference connected to a GNSS Simulator, which provides 1PPS Ref+10MHz Ref to the O-RU UNI. The O-DU UNI is connected to a chain of T-BC/T-TCs, which are connected to HSRs (HSR1, HSR2) and CSRs (CSR1, CSR2). The O-RU UNI is connected to two Clock Testers. The diagram includes timing constraints: TE ≤ 1100ns, TE ≤ 1325ns, TE ≤ 1420ns, and ±30-95ns --- ±50ns (FR2-FR1) --- (FR1). It also lists performance targets for Enhanced RU (FR2-FR1) and Regular RU (FR1).</p> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSRs.</p> | | | +| Test Configuration | <ol style="list-style-type: none"> <li>1. Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>3. G.8275.1 Full Timing Support profile as applicable.</li> </ol> | | | +| Procedure: | <b>Detailed Test procedure:</b> <ol style="list-style-type: none"> <li>1. Connect T-GM to O-DU via chain of T-BC/T-TCs.</li> <li>2. Configure O-DU and CSR as T-BC and HSR as either T-BC or T-TC.</li> <li>3. Enable G.8275.1 profile on HSR (when acting as T-BC), O-DU, CSR and T-GM.</li> </ol> | | | + +4. Connect Clock tester measurement ports to CSR1 and CSR2 TimeTransmitter ports to monitor the PTP at O-RU UNI. +5. Establish a PTP and SyncE session to the fronthaul network. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Perform time error measurements on Clock tester at O-RU UNI. +3. Verify time error measurements using Clock Tester at O-RU UNI. + - a. $\max |TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max |TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 UNI. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both the O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max |TE_{RL}| (1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max |TE_{RL}| (1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max |TE_{RL}| (1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max |TE_{RL}| (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum 1PPS Absolute Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max |TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max |TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max |TE_{RL}| (1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max |TE_{RL}| (1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max |TE_{RL}| (1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + +c. MTIE mask as per the limit specified. + +NOTE1: + +To measure the maximum relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +**Pass/Fail Criteria:** + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. + +**Test Output** + +| End-to-End Network Limit at O-RU UNI. | Expected Value | | Observed Value | +|---------------------------------------|-------------------|-------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| 1PPS $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| Frequency Limit (For O-DU Class-A) | $\leq 36ppb$ | $\leq 36ppb$ | | +| Frequency Limit (For O-DU Class-B) | $\leq 32ppb$ | $\leq 32ppb$ | | + +## 9.1.8 Network Time Synchronization-LLS-C2 (Option-B) configuration + +(Fail-over: Scenario-1) + +| <b>Test ID</b> | SYNC.TE.08 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error | +|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------------------------------------------| +| <b>Test Title</b> | Measurement of Frequency Error, Maximum Absolute Time Error at O-RU UNI LLS-C2 (Option-B): Dual-Homing with LAG at O-DU side | | | +| <b>Test Objective:</b> | 1. Verify the Maximum Absolute Packet Time Error ( $\max TE_L $ ) at O-RU UNI.<br>2. Verify the Maximum Absolute 1PPS Time Error ( $\max TE_L $ ) at O-RU UNI.<br>3. Verify the Time Wander at O-RU UNI. | | | +| <b>Pre-Req</b> | O-DU is the nearest common T-BC to O-RU UNI.<br>T-GM or PRTC connected to ODU via a chain of T-BC/T-TCs.<br>A pair of HSR nodes as T-TCs, with CSR dual-homed to the HSR's on one side and a pair of O-DU uplinks are bundled to LAG and connected to HSR node on the other side.<br>O-RU UNI is the measurement plane. | | | +| <b>Test Topology:</b> | <b>Normal Scenario</b> | | | + +![Diagram of the test topology for the normal scenario. A Frequency Reference and GNSS Simulator provide a 1PPS Ref+10MHz Ref signal to a T-GM block. The T-GM block outputs an RF Signal to a T-BC/T-TC block. The T-BC/T-TC block outputs to an O-DU block. The O-DU block outputs to an AE block. The AE block outputs to two HSR1 and HSR2 blocks. The HSR1 and HSR2 blocks output to a T-BC/T-TC block. The T-BC/T-TC block outputs to a CS1 block. The CS1 block outputs to a Clock Tester block. The Clock Tester block outputs a 1PPS out signal. The diagram shows timing constraints: |TE| ≤ 1100ns for the T-GM to T-BC/T-TC path, and |TE| ≤ 1465ns for the O-DU to O-RU UNI path. The HSR1 and HSR2 blocks are connected via PTP+SYNCE signals.](91fd388c9905d32d03f616187259e27f_img.jpg) + +Diagram of the test topology for the normal scenario. A Frequency Reference and GNSS Simulator provide a 1PPS Ref+10MHz Ref signal to a T-GM block. The T-GM block outputs an RF Signal to a T-BC/T-TC block. The T-BC/T-TC block outputs to an O-DU block. The O-DU block outputs to an AE block. The AE block outputs to two HSR1 and HSR2 blocks. The HSR1 and HSR2 blocks output to a T-BC/T-TC block. The T-BC/T-TC block outputs to a CS1 block. The CS1 block outputs to a Clock Tester block. The Clock Tester block outputs a 1PPS out signal. The diagram shows timing constraints: |TE| ≤ 1100ns for the T-GM to T-BC/T-TC path, and |TE| ≤ 1465ns for the O-DU to O-RU UNI path. The HSR1 and HSR2 blocks are connected via PTP+SYNCE signals. + +### Link Failure between O-DU and HSR1 + +![Diagram of the test topology for the link failure scenario between O-DU and HSR1. The setup is identical to the normal scenario, but the connection between the O-DU block and the HSR1 block is marked with a red 'X', indicating a link failure. The timing constraints remain the same: |TE| ≤ 1100ns and |TE| ≤ 1465ns.](5a8791c8bd300bbe0d810c8bcac2ba3d_img.jpg) + +Diagram of the test topology for the link failure scenario between O-DU and HSR1. The setup is identical to the normal scenario, but the connection between the O-DU block and the HSR1 block is marked with a red 'X', indicating a link failure. The timing constraints remain the same: |TE| ≤ 1100ns and |TE| ≤ 1465ns. + +### HSR Node Failure + +![Diagram of the test topology for the HSR node failure scenario. The setup is identical to the normal scenario, but the HSR1 block is marked with a red 'X', indicating a node failure. The timing constraints remain the same: |TE| ≤ 1100ns and |TE| ≤ 1465ns.](b116ae1f761a81b34f7d992965fe41c2_img.jpg) + +Diagram of the test topology for the HSR node failure scenario. The setup is identical to the normal scenario, but the HSR1 block is marked with a red 'X', indicating a node failure. The timing constraints remain the same: |TE| ≤ 1100ns and |TE| ≤ 1465ns. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSR. + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>3. G.8275.1 Full Timing Support profile as applicable.</li> </ol> | +| <b>Procedure:</b> | <b>Case-1: Normal Scenario</b> | + +### **Detailed Test procedure** + +1. Connect T-GM to O-DU via a chain of T-BC/T-TCs. +2. Configure O-DU and CSR as T-BC and HSR as T-TC. +3. Enable G.8275.1 profile on CSR and T-GM. +4. Connect Clock tester measurement ports to CSR TimeTransmitter port to monitor the PTP at O-RU UNI. +5. Establish PTP and SyncE session to the fronthaul network. + +### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Verify time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +### **Verifications for Maximum 1PPS Absolute Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +### **Case-2: Link Fail between O-DU and HSR1** + +### **Detailed Test procedure** + +1. Fail the link between O-DU and HSR1. + +### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP session is established via the path O-DU-HSR2-CSR1 and CSR1 lock to O-DU via HSR-2. +2. Verify time error measurements using Clock tester on O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +### **Verifications for Maximum 1PPS Absolute Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +### Verifications for Time Wander + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 36\text{ppb}$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32\text{ppb}$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +### Case-3: HSR1 Node Fail + +### Detailed Test procedure + +1. Fail the node HSR1 by power off. + +### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is established via the path O-DU-HSR2-CSR1 and CSR1 lock to O-DU via HSR2. +2. Verify the time error measurements using Clock Tester on O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465\text{ns}$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420\text{ns}$ (For Regular RU) + +### Verifications for Maximum 1PPS Absolute Time Error + +1. Verify that PTP and SyncE session is up and running. +2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465\text{ns}$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420\text{ns}$ (For Regular RU) + +### Verifications for Time Wander + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 36\text{ppb}$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32\text{ppb}$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +### **Pass/Fail Criteria:** + +Test shall pass if the Maximum absolute TE and Time Wander Limit measurement result is below the limit specified. + +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------|--------------------------------------|----------------------|----------------------|----------------| +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1465\text{ns}$ | $\leq 1420\text{ns}$ | | +| | 1PPS $\max TE_L $ | $\leq 1465\text{ns}$ | $\leq 1420\text{ns}$ | | +| | Frequency Limit (For O-DU Class-A) | $\leq 36\text{ppb}$ | $\leq 36\text{ppb}$ | | +| | Frequency Limit (For O-DU Class-B) | $\leq 32\text{ppb}$ | $\leq 32\text{ppb}$ | | + +## 9.1.9 Network Time Synchronization-LLS-C2 (Option-B) configuration (Fail-over: Scenario-2) + +| Test ID | SYNC.TE.09 | Classification | Synchronization, Performance, Absolute Time Error | +|-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|---------------------------------------------------| +| Test Title | Measurement of Frequency Error, Maximum Absolute Time Error at O-RU UNI<br>LLS-C2 (Option-B): Dual-Homing with AE at O-DU side | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>3. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| Pre-Req | <p>Nearest common node to O-RU UNI is O-DU.</p> <p>T-GM or PRTC connected to ODU via a chain of T-BC/T-TCs.</p> <p>A pair of HSR nodes as T-TCs, with CSR dual-homed to the HSR's on one side and a pair of O-DU uplinks are bundled to AE and connected to HSR node on the other side.</p> <p>O-RU UNI is the measurement plane.</p> | | | + +### Test Topology: + +#### Normal Scenario + +![Normal Scenario topology diagram showing time synchronization flow from Frequency Reference through GNSS Simulator, T-GM, T-BC/T-TC, O-DU, HSR1/HSR2, T-BC/CSR1, and finally to Clock Tester at O-RU UNI. It includes PTP and SyncE links and time error (ITE) constraints.](9c7a41a4a0c7558cfd63db5f0bc20005_img.jpg) + +The diagram illustrates the Normal Scenario for network time synchronization. A Frequency Reference is connected to a GNSS Simulator, which provides a 1PPS Ref+10MHz Ref signal. This signal is processed by a T-GM (PRTC-A, |TE|≤100ns; PRTC-B, |TE|≤40ns; ePRTC, |TE|≤30ns) and then passes through a T-BC/T-TC block. The signal then enters the O-DU UNI, where it is processed by an O-DU (T-BC/EEC/EEC). From the O-DU, the signal is distributed to two HSR nodes (HSR1 and HSR2, both T-TC/EEC/EEC) via PTP links. These HSR nodes are connected to a T-BC/CSR1 block (T-BC/EEC/EEC) via SyncE links. The T-BC/CSR1 block then outputs a 1PPS out signal to a Clock Tester at the O-RU UNI. Time error (ITE) constraints are specified: |ITE|≤1100ns between the T-GM and the O-DU, and |ITE|≤1465ns between the O-DU and the O-RU UNI. + +Normal Scenario topology diagram showing time synchronization flow from Frequency Reference through GNSS Simulator, T-GM, T-BC/T-TC, O-DU, HSR1/HSR2, T-BC/CSR1, and finally to Clock Tester at O-RU UNI. It includes PTP and SyncE links and time error (ITE) constraints. + +#### Link Fail between HSR1 and CSR1 + +![Link Fail between HSR1 and CSR1 topology diagram, showing an Assisted Holdover state where the connection between HSR1 and CSR1 is broken, indicated by a red X.](4fd0af66099f1cf653113a855ff64e17_img.jpg) + +This diagram shows the Link Fail scenario between HSR1 and CSR1. The topology is identical to the Normal Scenario, but the connection between HSR1 and CSR1 is broken, indicated by a red 'X'. In this state, the system enters an 'Assisted Holdover' mode. The time error (ITE) constraints remain the same: |ITE|≤1100ns between the T-GM and the O-DU, and |ITE|≤1465ns between the O-DU and the O-RU UNI. + +Link Fail between HSR1 and CSR1 topology diagram, showing an Assisted Holdover state where the connection between HSR1 and CSR1 is broken, indicated by a red X. + +#### HSR Node Failure + +![Test topology diagram showing the placement of a clock tester at the measurement plane. The diagram illustrates the signal flow from a GNSS Simulator through various network components (T-GM, T-BC, T-TC, O-DU, HSR, CSR) to a Clock Tester. Key components include Frequency Reference, GNSS Simulator, T-GM, T-BC, T-TC, O-DU, HSR1, HSR2, CSR1, and Clock Tester. The diagram shows PTP and SyncE sessions between O-DU and CSR, and an Assisted Holdover session between CSR and the Clock Tester. Timing constraints are specified: |TE| ≤ 1100ns for the T-GM to T-BC path, |TE| ≤ 1465ns for the O-DU to CSR path, and |TE| ≤ 1465ns for the CSR to Clock Tester path. The GNSS Simulator provides 1PPS Ref and 10MHz Ref signals to the T-GM and the Clock Tester.](e1b881026b9f023cdb209c9e928dca04_img.jpg) + +Test topology diagram showing the placement of a clock tester at the measurement plane. The diagram illustrates the signal flow from a GNSS Simulator through various network components (T-GM, T-BC, T-TC, O-DU, HSR, CSR) to a Clock Tester. Key components include Frequency Reference, GNSS Simulator, T-GM, T-BC, T-TC, O-DU, HSR1, HSR2, CSR1, and Clock Tester. The diagram shows PTP and SyncE sessions between O-DU and CSR, and an Assisted Holdover session between CSR and the Clock Tester. Timing constraints are specified: |TE| ≤ 1100ns for the T-GM to T-BC path, |TE| ≤ 1465ns for the O-DU to CSR path, and |TE| ≤ 1465ns for the CSR to Clock Tester path. The GNSS Simulator provides 1PPS Ref and 10MHz Ref signals to the T-GM and the Clock Tester. + +The test topology above illustrates the placement of clock tester at measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. + +### Test Configuration + +1. Clock Tester at O-RU UNI receives timing input on its measurement port. +2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +3. G.8275.1 Full Timing Support profile as applicable. + +### Procedure: + +#### Case-1: Normal Scenario + +##### Detailed Test procedure + +1. Connect T-GM to O-DU via a chain of T-BC/T-TCs. +2. Configure O-DU and CSR as T-BC and HSR as T-TC. +3. Enable G.8275.1 profile on CSR and T-GM. +4. Connect Clock tester measurement ports to CSR TimeTransmitter port to monitor the PTP at O-RU UNI. +5. Establish PTP and SyncE session to the fronthaul network. + +##### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP and SyncE session is up and running. +2. Configure PTP on the primary path and SyncE on the standby path. +3. Verify time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465\text{ns}$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420\text{ns}$ (For Regular RU) + +##### Verifications for Maximum 1PPS Absolute Time Error + +1. Verify that PTP and SyncE session is up and running. +2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465\text{ns}$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420\text{ns}$ (For Regular RU) + +##### Verifications for Time Wander + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 36\text{ppb}$ (For O-DU Class-A) + +- b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) +- c. MTIE mask as per the limit specified. + +### **Case-2: Link Fail between HSR1 and CSR** + +#### **Detailed Test procedure** + +1. Fail the link between HSR1 and CSR. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that the PTP session on CSR moves to Assisted Holdover with Physical layer SyncE via the standby path. +2. Perform time error measurements on Clock tester on O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Maximum 1PPS Absolute Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +### **Case-3: HSR1 Node Fail** + +#### **Detailed Test procedure** + +1. Fail the node HSR1 by power off. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP session on CSR moves to Assisted Holdover with SyncE via the standby path. +2. Perform time error measurements on Tester on O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Maximum 1PPS Absolute Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Time Wander** + +| | | | | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------|------------------|----------------| +| | 1. Verify the Time Wander using Clock tester at the O-RU UNI. <ol style="list-style-type: none"> <li>Frequency Limit is <math>\le 36ppb</math> (For O-DU Class-A)</li> <li>Frequency Limit is <math>\le 32ppb</math> (For O-DU Class-B)</li> <li>MTIE mask as per the limit specified.</li> </ol> | | | | +| | <b>Pass/Fail Criteria:</b> Test shall pass if the Maximum absolute TE and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet max $ TE_L $ | $\le 1465ns$ | $\le 1420ns$ | | +| | 1PPS max $ TE_L $ | $\le 1465ns$ | $\le 1420ns$ | | +| | Frequency Limit (For O-DU Class-A) | $\le 36ppb$ | $\le 36ppb$ | | +| | Frequency Limit (For O-DU Class-B) | $\le 32ppb$ | $\le 32ppb$ | | + +## 9.1.10 Network Time Synchronization-LLS-C2 (Option-B) configuration + +### (Fail-over: Scenario-3) + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|---------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.10 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error | +| <b>Test Title</b> | Measurement of Frequency Error, Maximum Absolute Time Error at O-RU UNI LLS-C2 (Option-B): Dual-Homing with dual/redundant O-DU | | | +| <b>Test Objective:</b> | 1. Verify the Maximum Absolute Packet Time Error ( $Max TE_L $ ) at O-RU UNI.<br>2. Verify the Maximum Absolute 1PPS Time Error ( $Max TE_L $ ) at O-RU UNI.<br>3. Verify the Time Wander at O-RU UNI. | | | +| <b>Pre-Req</b> | T-GM or PRTC connected to O-DUs via T-BC chain.<br>A pair of HSR nodes, with CSR dual-homed to the HSR's on one side and a pair of O-DU uplinks are bundled to AE and connected to HSR node on the other side.<br>O-RU UNI is the measurement plane. | | | +| <b>Test Topology:</b> | <b>Normal Scenario</b> | | | + +![Diagram of the test topology for clock testing. A GNSS Simulator provides a 1PPS Ref+10MHz Ref signal to a T-GM block and an RF Signal to a T-BC/T-TC block. The T-GM block outputs PRTC-A, |TE|≤100ns; PRTC-B, |TE|≤40ns; ePRTC, |TE|≤30ns. The T-BC/T-TC block is connected to O-DU1 and O-DU2. O-DU1 and O-DU2 are connected to HSR1 and HSR2. HSR1 and HSR2 are connected to a CSR block. The CSR block is connected to a Clock Tester. The Clock Tester outputs 1PPS out. Timing constraints are shown: |TE|≤1100ns for the T-GM to O-DU1 path and |TE|≤1465ns for the O-DU1 to Clock Tester path.](acc0e87c785d6661f82604905385a7a4_img.jpg) + +Diagram of the test topology for clock testing. A GNSS Simulator provides a 1PPS Ref+10MHz Ref signal to a T-GM block and an RF Signal to a T-BC/T-TC block. The T-GM block outputs PRTC-A, |TE|≤100ns; PRTC-B, |TE|≤40ns; ePRTC, |TE|≤30ns. The T-BC/T-TC block is connected to O-DU1 and O-DU2. O-DU1 and O-DU2 are connected to HSR1 and HSR2. HSR1 and HSR2 are connected to a CSR block. The CSR block is connected to a Clock Tester. The Clock Tester outputs 1PPS out. Timing constraints are shown: |TE|≤1100ns for the T-GM to O-DU1 path and |TE|≤1465ns for the O-DU1 to Clock Tester path. + +### O-DU Failure Scenario + +![Diagram of the O-DU Failure Scenario. The topology is identical to the previous diagram, but O-DU1 is crossed out with a red X, indicating a failure. The timing constraints remain the same: |TE|≤1100ns and |TE|≤1465ns.](1a5e6b7aa43e92eeb959730af7368631_img.jpg) + +Diagram of the O-DU Failure Scenario. The topology is identical to the previous diagram, but O-DU1 is crossed out with a red X, indicating a failure. The timing constraints remain the same: |TE|≤1100ns and |TE|≤1465ns. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSR. + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>3. G.8275.1 Full Timing Support profile as applicable.</li> </ol> | +| <b>Procedure:</b> | <p><b>Case-1: Normal Scenario</b></p> <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect T-GM to O-DU via a chain of T-BC/T-TCs.</li> <li>2. Configure O-DU1, O-DU2 and CSR as T-BC. HSR1 and HSR2 as T-TC.</li> <li>3. Enable G.8275.1 profile on CSR and T-GM.</li> <li>4. Connect Clock tester measurement ports to CSR TimeTransmitter port to monitor the PTP at O-RU UNI.</li> <li>5. Establish PTP and SyncE session to the fronthaul network.</li> </ol> <p><b>Verifications for Maximum Absolute Packet Time Error</b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP session is up and running.</li> <li>2. Verify that PTP session is established on the Primary path T-GM-O-DU1-HSR1-CSR and CSR lock to O-DU1 via HSR1.</li> <li>3. Perform time error measurements on Tester on O-RU UNI.</li> </ol> | + +- a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) +- b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Maximum 1PPS Absolute Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Verify the 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +#### **Case-2: O-DU1 Fail** + +#### **Detailed Test procedure** + +1. Fail the node O-DU1 by power off. + +#### **Verifications for Maximum Absolute Time Error** + +1. Verify that PTP session is established via the path O-DU2-HSR1-CSR and CSR lock to HSR1. +2. Perform time error measurements on Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Maximum 1PPS Absolute Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +| | | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------|-------------------|------------------|----------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum absolute TE and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | + + + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSRs. | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>Multiple Transport TNEs (HSR1, HSR2, CSR1 and CSR2) connected and configured as shown in the Test Topology.</li> <li>Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>Traffic Tester for emulating Background Traffic for the desired packet sizes and rate.</li> <li>Proper QoS configuration on TNEs to make sure PTP packets not congested in the network.</li> <li>G.8275.1 Full Timing Support profile.</li> </ol> | +| <b>Procedure:</b> | <p><b><u>Case-1: Normal Scenario (with no background traffic)</u></b></p> <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>Connect T-GM to GNSS simulator and ensure that T-GM is locked.</li> <li>Connect O-DU directly to T-GM.</li> <li>Configure O-DU, CSR1 and CSR2 as T-BCs. HSR1 and HSR2 as either T-BCs or T-TCs.</li> <li>Enable G.8275.1 profile on all transport TNEs (HSR and CSR).</li> <li>Connect Clock tester measurement ports to CSRs TimeTransmitter port to monitor the PTP at O-RU UNI.</li> <li>Establish PTP and SyncE session to the fronthaul network.</li> </ol> <p><b><u>Verifications for Maximum Absolute Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify that PTP session is up and running between T-GM and CSR.</li> <li>Verify time error measurements using the Clock Tester for the PTP flows from CSR at the O-RU UNI. <ol style="list-style-type: none"> <li>Max <math> TE </math> measured on Clock Tester at the O-RU UNI <math>\leq 1465ns</math> (For Enhanced RU)</li> <li>Max <math> TE </math> measured on Clock Tester at the O-RU UNI <math>\leq 1420ns</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error (NOTE1)</u></b></p> <ol style="list-style-type: none"> <li>Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data (<math>maxTE1, minTE1</math>) and (<math>maxTE2, minTE2</math>) for both O-RU UNI at least for a period of 1000sec.</li> <li>Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li><math>max TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li><math>max TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li><math>max TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TERL(t)</math>, but to measure the maximum possible value it can take.</p> | + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum 1PPS Absolute Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Verify 1PPS time error measurements using Clock Tester at O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at O-RU UNI. + - a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +#### **Case-2: With background traffic** + +##### **Detailed Test procedure:** + +1. Configure proper QoS on each of the TNEs so that PTP packets are not congested in the network. +2. Create traffic flows, especially the traffic types, rate and packet sizes should be as per FH requirements. (Refer the Section 7.2 in Xhaul Transport Requirements documents for details). +3. Start traffic flows on all the Traffic Tester ports and make sure that no traffic loss observed. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that the PTP traffic is not dropped with background traffic. +2. Verify time error measurements using the Clock Tester for the PTP flows from CSR at the O-RU UNI in presence of the Background traffic. + - a. Max |TE| measured on Clock Tester at the O-RU UNI $\leq 1465ns$ (For Enhanced RU) + - b. Max |TE| measured on Clock Tester at the O-RU UNI $\leq 1420ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data $(\max TE1, \min TE1)$ and $(\max TE2, \min TE2)$ for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports in presence of the Background traffic. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + +| | <p>b. <math>\max TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</p> <p>c. <math>\max TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</p> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TERL(t)</math>, but to measure the maximum possible value it can take.</p> $\max TE_{RL} (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$ <p><b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify that PTP session is up and running between T-GM and CSR.</li> <li>Verify 1PPS time error measurements on Clock Tester at the O-RU UNI. <ol style="list-style-type: none"> <li><math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1465ns</math> (For Enhanced RU)</li> <li><math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1420ns</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify that PTP and SyncE session is up and running.</li> <li>Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li><math>\max TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Time Wander</u></b></p> <ol style="list-style-type: none"> <li>Verify the Time Wander using Clock tester at the O-RU UNI. <ol style="list-style-type: none"> <li>Frequency Limit is <math>\leq 36ppb</math> (For O-DU Class-A)</li> <li>Frequency Limit is <math>\leq 32ppb</math> (For O-DU Class-B)</li> <li>MTIE mask as per the limit specified.</li> </ol> </li> </ol> <p>NOTE1 (As per G.8271.1):<br/>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | | | | | | | | | | | | | | | | | | | | | | | | | +|--------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------|----------------|--|----------------|-------------------|------------------|---------------------|---------------|---------------|--|------------------------|-------------------|--------------------|--|--------------------|-------------------|---------------|---------------|--|----------------------|-------------------|--------------------|--|--------------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified with and without background traffic. | | | | | | | | | | | | | | | | | | | | | | | | | +| <b>Test Output</b> | <table border="1"> <tr> <th rowspan="2">End-to-End Network Limit at R-RU UNI</th> <th colspan="2">Expected Value</th> <th rowspan="2">Observed Value</th> </tr> <tr> <th>(For Enhanced RU)</th> <th>(For Regular RU)</th> </tr> <tr> <td>Packet <math>\max TE_L </math></td> <td><math>\leq 1465ns</math></td> <td><math>\leq 1420ns</math></td> <td></td> </tr> <tr> <td rowspan="2">Packet <math>\max TE_{RL} </math></td> <td><math>\leq 60ns</math>(FR2)</td> <td rowspan="2"><math>\leq 100ns</math>(FR1)</td> <td rowspan="2"></td> </tr> <tr> <td><math>\leq 190ns</math>(FR1)</td> </tr> <tr> <td>1PPS <math>\max TE_L </math></td> <td><math>\leq 1465ns</math></td> <td><math>\leq 1420ns</math></td> <td></td> </tr> <tr> <td rowspan="2">1PPS <math>\max TE_{RL} </math></td> <td><math>\leq 60ns</math>(FR2)</td> <td rowspan="2"><math>\leq 100ns</math>(FR1)</td> <td rowspan="2"></td> </tr> <tr> <td><math>\leq 190ns</math>(FR1)</td> </tr> </table> | End-to-End Network Limit at R-RU UNI | Expected Value | | Observed Value | (For Enhanced RU) | (For Regular RU) | Packet $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | $\leq 190ns$ (FR1) | 1PPS $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | $\leq 190ns$ (FR1) | +| End-to-End Network Limit at R-RU UNI | Expected Value | | Observed Value | | | | | | | | | | | | | | | | | | | | | | | +| | (For Enhanced RU) | (For Regular RU) | | | | | | | | | | | | | | | | | | | | | | | | +| Packet $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | | | | | | | | | | | | | | | | | | | | | | | +| Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | | | | | | | | | | | | | | | | | | | | | | | +| | $\leq 190ns$ (FR1) | | | | | | | | | | | | | | | | | | | | | | | | | +| 1PPS $\max TE_L $ | $\leq 1465ns$ | $\leq 1420ns$ | | | | | | | | | | | | | | | | | | | | | | | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | | | | | | | | | | | | | | | | | | | | | | | +| | $\leq 190ns$ (FR1) | | | | | | | | | | | | | | | | | | | | | | | | | + +| | | | | | +|--|---------------------------------------|--------------|--------------|--| +| | Frequency Limit<br>(For O-DU Class-A) | $\leq 36ppb$ | $\leq 36ppb$ | | +| | Frequency Limit<br>(For O-DU Class-B) | $\leq 32ppb$ | $\leq 32ppb$ | | + +## 9.1.12 Network Time Synchronization-LLS-C2 (Option-B) configuration + +(SyncE network wander limit for chain of EEC and eEEC clock) + +| | | | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|-----------------------------------------------| +| <b>Test ID</b> | SYNC.TE.12 | <b>Classification</b> | Synchronization, Performance, Frequency Error | +| <b>Test Title</b> | Measurement of Time Wander at O-RU UNI. LLS-C2 (Option-B) | | | +| <b>Test Objective:</b> | Verify the Time Wander at O-RU UNI. | | | +| <b>Pre-Req</b> | TNEs in the network chain should support either ITU-T G.8262 EEC clock or ITU-T G.8262.1 eEEC clock.<br>O-RU UNI is the measurement plane. | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A block diagram showing the test setup. A GNSS Simulator provides a 10MHz Ref signal to the O-DU UNI and an RF Signal to a T-GM. The T-GM is connected to PRTC-A, PRTC-B, and ePRTC. The O-DU UNI is connected to O-DU1 (EEC/eEEC) and O-DU2 (EEC/eEEC). These are connected to a central network block containing HSR1 (EEC/eEEC), HSR2 (EEC/eEEC), CSR1 (eEEC), and CSR2 (eEEC). The network block is connected to the O-RU UNI, which is connected to two Clock Testers. A dashed line labeled 'Network Wander Limit' spans from the T-GM to the O-RU UNI." data-bbox="414 963 1420 1456" src="b2e11efbd210f9f675c1f45d001ab48e_img.jpg"/> <p>The test topology above illustrates the placement of clock tester at measurement location with 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSRs.</p> | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>Provide 10MHz reference to Clock Tester from GNSS simulator.</li> </ol> | | | +| <b>Procedure:</b> | <p><b><u>Case1: Synchronous chain of ITU-T G.8262 EEC clock</u></b></p> <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>Configure Synchronous Ethernet with ESMC on all the nodes.</li> <li>Connect Clock tester measurement ports to CSRs to monitor the output wander at the O-RU UNI.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>Verify that SyncE is up and ESMC-QL is traceable to that of T-GM.</li> <li>Perform the Time Interval Error measurements on Clock Tester at the O-RU UNI.</li> </ol> | | | + +3. Verify the Time Wander at O-RU UNI. + - a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +**Case2: Synchronous chain of ITU-T G.8262.1 eEEC clock** + +**Detailed Test procedure:** + +1. Configure Synchronous Ethernet with eESMC on all the nodes. +2. Connect Clock tester measurement ports to CSRs to monitor the output wander at the O-RU UNI. + +**Verifications needed:** + +1. Verify that SyncE is up and eESMC-QL is traceable to that of T-GM. +2. Perform the Time Interval Error measurements on Clock Tester at the O-RU UNI. +3. Verify the Time Wander at O-RU UNI. + - a. Frequency Limit is $\leq 36ppb$ (For O-DU Class-A) + - b. Frequency Limit is $\leq 32ppb$ (For O-DU Class-B) + - c. MTIE mask as per the limit specified. + +| | | | | | +|----------------------------|------------------------------------------------------------------------------------------|----------------|--------------|----------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the measurement of Time Wander limits are below the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (Enhanced RU) | (Regular RU) | | +| | Frequency Limit (For O-DU Class-A) | $\leq 36ppb$ | $\leq 36ppb$ | | +| | Frequency Limit (For O-DU Class-B) | $\leq 32ppb$ | $\leq 32ppb$ | | + +## 9.1.13 Network Time Synchronization-LLS-C2 (Option-B) configuration + +### (1PPS Time Error on O-RU) + +| | | | | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.13 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of 1PPS Absolute Time Error, 1PPS Relative Time Error at O-RU. LLS-C2 (Option-B) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the 1PPS Maximum Absolute Time Error at O-RU.</li> <li>2. Verify the 1PPS Maximum Relative Time Error between the O-RU UNI ports.</li> </ol> | | | +| <b>Pre-Req</b> | O-RU must support 1PPS out interface.<br>T-GM/PRTC connected to O-DU via chain of T-BC/T-TCs. O-DU is locked. | | | +| <b>Test Topology:</b> | 1PPS Absolute Time Error | | | + +![Block diagram for 1PPS Absolute Time Error measurement. A Frequency Reference feeds a GNSS Simulator, which provides a 1PPS Ref signal. The RF Signal path goes through a T-GM block (PRTC-A, |TE| ≤ 100ns; PRTC-B, |TE| ≤ 40ns; ePRTC, |TE| ≤ 30ns) and a chain of T-BC/T-TC blocks. The signal then passes through O-DU UNI (O-DU1, O-DU2) and a central processing block (HSR1, HSR2, CSR1, CSR2) containing T-BC/T-TC blocks. Finally, it reaches O-RU UNI (O-RU enhanced, O-RU regular) which includes T-TSC blocks. The O-RU enhanced block has |TE| ≤ 35ns and the O-RU regular block has |TE| ≤ 80ns. A Clock Tester measures the 1PPS Measurement at the O-RU UNI. Timing constraints include |TE| ≤ 1100ns and 1PPS Max TE ≤ 1480ns.](2dd711da7aa0ecebf64ad7b83325da13_img.jpg) + +Block diagram for 1PPS Absolute Time Error measurement. A Frequency Reference feeds a GNSS Simulator, which provides a 1PPS Ref signal. The RF Signal path goes through a T-GM block (PRTC-A, |TE| ≤ 100ns; PRTC-B, |TE| ≤ 40ns; ePRTC, |TE| ≤ 30ns) and a chain of T-BC/T-TC blocks. The signal then passes through O-DU UNI (O-DU1, O-DU2) and a central processing block (HSR1, HSR2, CSR1, CSR2) containing T-BC/T-TC blocks. Finally, it reaches O-RU UNI (O-RU enhanced, O-RU regular) which includes T-TSC blocks. The O-RU enhanced block has |TE| ≤ 35ns and the O-RU regular block has |TE| ≤ 80ns. A Clock Tester measures the 1PPS Measurement at the O-RU UNI. Timing constraints include |TE| ≤ 1100ns and 1PPS Max TE ≤ 1480ns. + +1PPS Relative Time Error + +![Block diagram for 1PPS Relative Time Error measurement. The architecture is identical to the previous diagram, showing the signal path from Frequency Reference through GNSS Simulator, T-GM, T-BC/T-TC chain, O-DU UNI, central processing block, and O-RU UNI to the Clock Tester. Timing constraints include |TE| ≤ 1100ns and 1PPS Max TE ≤ 1480ns.](791cc4558f31eae5cc1aaeb5246fed89_img.jpg) + +Block diagram for 1PPS Relative Time Error measurement. The architecture is identical to the previous diagram, showing the signal path from Frequency Reference through GNSS Simulator, T-GM, T-BC/T-TC chain, O-DU UNI, central processing block, and O-RU UNI to the Clock Tester. Timing constraints include |TE| ≤ 1100ns and 1PPS Max TE ≤ 1480ns. + +### **Test Configuration** + +1. Clock Tester at O-RU UNI receives timing input on its measurement port. +2. Provide 1PPS reference to Clock Tester from GNSS simulator. + +### **Procedure:** + +#### **Case-1: 1PPS Absolute Time Error Measurement.** + +##### **Detailed Test procedure:** + +1. Connect T-GM to O-DUs via chain of T-BC/T-TCs. +2. Configure O-DU and CSR as T-BC and HSR as either T-BC or T-TC. +3. Enable G.8275.1 profile on HSR (when acting as T-BC), CSR and T-GM. +4. Connect Clock tester 1PPS measurement ports to O-RU 1PPS output ports. +5. Establish PTP and SyncE session to the fronthaul network. + +##### **Verifications needed:** + +1. Verify that PTP session is up and running. +2. Verify 1PPS time error measurements using the Clock Tester at O-RU UNI. + - a. $1 ext{PPS } ext{max}|TE_L|$ measured on Tester at the O-RU (Enhanced) output $\le 1480 ext{ns}$ + - b. $1 ext{PPS } ext{max}|TE_L|$ measured on Tester at the O-RU (Regular) output $\le 1480 ext{ns}$ + +#### **Case-1: 1PPS Relative Time Error Measurement.** + +| | | | | | +|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------|----------------|---------------|----------------| +| <b>Detailed Test procedure:</b> <ol style="list-style-type: none"> <li>1. Connect 1PPS output ports from both O-RU to tester 1PPS measurement Input ports simultaneously.</li> </ol> <b>Verifications needed:</b> <ol style="list-style-type: none"> <li>1. Verify the 1PPS relative time error between O-RU1 and O-RU2 <math>\leq 2960ns</math></li> </ol> | | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the 1PPS Maximum absolute TE and 1PPS Maximum Relative TE measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit | Expected Value | | Observed Value | +| | | (Enhanced RU) | (Regular RU) | | +| | 1PPS $\max TE_L $ | $\leq 1480ns$ | $\leq 1480ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 2960ns$ | $\leq 2960ns$ | | + +1 + +### 9.1.14 Network Time Synchronization-LLS-C3 (Option-A) configuration + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.14 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Frequency Error, Absolute Time Error, Relative Time Error at O-RU UNI. LLS-C3 (Option-A) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>\max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>5. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | T-GM/PRTC connected to GNSS simulator and ensure T-GM is locked.<br>O-RU UNI is the measurement plane. | | | + +## Test Topology: + +![Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, O-DU, HSR, CSR, and Clock Testers.](225a45855711c01be0ebdf272e6e6968_img.jpg) + +The diagram illustrates the test topology for clock synchronization. A **Frequency Reference** and **GNSS Simulator** provide an **RF Signal** and **1PPS Ref+10MHz Ref** to the **T-GM** (Timing and Synchronization Manager). The T-GM is connected to four transport TNEs (T-NEs) within a dashed circle: **HSR1**, **HSR2**, **CSR1**, and **CSR2**. Each T-NE contains a **T-TSC/EEC/eEEC** block. The T-GM also provides timing signals to these T-NEs: **PRTC-A, |TE| ≤ 100ns**, **PRTC-B, |TE| ≤ 40ns**, and **ePRTC, |TE| ≤ 30ns**. The T-NEs are connected to the **O-DU UNI** (O-DU User Network Interface) and the **O-RU UNI** (O-RU User Network Interface). The O-DU UNI is connected to two **O-DU** blocks, each containing a **T-TSC/EEC/eEEC** block. The O-RU UNI is connected to two **Clock Tester** blocks. The Clock Testers receive **1PPS out** signals from the CSR1 and CSR2 T-NEs. The maximum time error at the O-RU UNI is specified as $\text{Max } |TE_{RL}| = 2200\text{ns}$ . The total time error across the network is specified as $|TE| \leq 1100\text{ns}$ . + +Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, O-DU, HSR, CSR, and Clock Testers. + +The test topology above illustrates the placement of clock tester at measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSR. + +## Test Configuration + +1. Multiple Transport TNEs (HSR1, HSR2, CSR1 and CSR2) connected and configured as shown in the Test Topology. +2. Clock Tester at O-RU UNI receives timing input on its measurement port. +3. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +4. G.8275.1 Full Timing Support profile. + +## Procedure: + +### Detailed Test procedure: + +1. Connect T-GM to GNSS simulator and ensure that T-GM is locked. +2. Configure O-DU as T-TSC, CSR1 and CSR2 as T-BCs. HSR1 and HSR2 as either T-BCs or T-TCs. +3. Enable G.8275.1 profile on all transport TNEs (HSR and CSR). +4. Connect Clock tester measurement ports to CSRs TimeTransmitter port to monitor the PTP at O-RU UNI. +5. Establish PTP and SyncE session to the fronthaul network. + +### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using the Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\text{max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100\text{ns}$ (For Enhanced RU) + - b. $\text{max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100\text{ns}$ (For Regular RU) + +### Verifications for Maximum Relative Packet Time Error (NOTE1) + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $maxTE1, minTE1$ ) and ( $maxTE2, minTE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the TimeTransmitter ports on CSR1 and CSR2 at O-RU UNI. + - a. $\max|TE_{RL}| (1,2) \leq 2200ns$ + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TERL(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}| (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements on Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}| (1,2) \leq 2200ns$ + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### **Pass/Fail Criteria:** + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified with and without background traffic. + +#### **Test Output** + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|-------------------|------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\max TE_{RL} $ | $\leq 2200ns$ | $\leq 2200ns$ | | +| 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 2200ns$ | $\leq 2200ns$ | | +| Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +1 + +## 9.1.15 Network Time Synchronization-LLS-C3 (Option-B) configuration + +| Test ID | SYNC.TE.15 | Classification | Synchronization, Performance, Absolute Time Error, Relative Time Error | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------| +| Test Title | Measurement of Frequency Error, Absolute Time Error, Relative Time Error at O-RU UNI. LLS-C3 (Option-B) | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at O-RU UN.</li> <li>5. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| Pre-Req | T-GM/PRTC connected to GNSS simulator and ensure T-GM is locked.<br>O-RU UNI is the measurement plane. | | | +| Test Topology: | <p>Image: Test Topology Diagram for Network Time Synchronization-LLS-C3 (Option-B). The diagram shows a central T-GM block connected to a GNSS Simulator. The GNSS Simulator provides an RF Signal to the T-GM and a 1PPS Ref+10MHz Ref signal to two Clock Testers. The T-GM is connected to a T-BC block, which is connected to four transport NEs (HSR1, HSR2, CSR1, CSR2). Each transport NE is connected to an O-DU block. The O-DU blocks are connected to the O-RU UNI. The T-BC block is connected to the O-RU UNI. The O-RU UNI is connected to the Clock Testers. The diagram also shows timing constraints: TE ≤ 1100ns for the T-BC to O-DU path and TE ≤ 1100ns for the T-BC to O-RU UNI path. Performance targets are listed for Enhanced RU (PR2-PR1) and Regular RU (PR1).</p> <p>Frequency Reference → GNSS Simulator → RF Signal → T-GM</p> <p>GNSS Simulator → 1PPS Ref+10MHz Ref → Clock Tester</p> <p>T-GM → T-BC → HSR1, HSR2, CSR1, CSR2 → O-DU → O-RU UNI</p> <p>T-BC → O-RU UNI</p> <p>O-RU UNI → Clock Tester</p> <p>Timing Constraints: <math> TE \leq 1100ns</math></p> <p>Performance Targets:</p> <ul style="list-style-type: none"> <li>For Enhanced RU (PR2-PR1) <ul style="list-style-type: none"> <li>Max <math> TE_{RL} = 60-190ns</math> at O-RU UNI</li> <li>Max TAE = 130-260ns</li> </ul> </li> <li>For Regular RU (PR1) <ul style="list-style-type: none"> <li>Max <math> TE_{RL} = 100ns</math> at O-RU UNI</li> <li>Max TAE = 260ns</li> </ul> </li> </ul> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSR.</p> | | | +| Test Configuration | <ol style="list-style-type: none"> <li>1. Multiple Transport TNEs (HSR1, HSR2, CSR1 and CSR2) connected and configured as shown in the Test Topology.</li> <li>2. Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>3. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>4. G.8275.1 Full Timing Support profile.</li> </ol> | | | +| Procedure: | <b>Detailed Test procedure:</b> <ol style="list-style-type: none"> <li>1. Connect T-GM to GNSS Simulator and ensure that T-GM is locked.</li> </ol> | | | + +2. Configure O-DU as T-TSC, CSR1 and CSR2 as T-BCs. HSR1 and HSR2 as either T-BCs or T-TCs. +3. Enable G.8275.1 profile on all transport TNEs (HSR, CSR and T-BC). +4. Connect Clock tester measurement ports to CSRs TimeTransmitter port to monitor the PTP at O-RU UNI. +5. Establish PTP and SyncE session to the fronthaul network. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data $(\max TE1, \min TE1)$ and $(\max TE2, \min TE2)$ for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements on Clock Tester at the O-RU UNI. + - a. Max 1PPS $|TE|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU (Regular) UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + +| | | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------|--------------------------|----------------| +| | <ol style="list-style-type: none"> <li>Frequency Limit is <math>\le 32\text{ppb}</math> (For PRTC Class-A)</li> <li>MTIE mask as per the limit specified.</li> </ol> <p>NOTE1:<br/> To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\le 1100\text{ns}$ | $\le 1100\text{ns}$ | | +| | Packet $\max TE_{RL} $ | $\le 60\text{ns} (FR2)$<br>$\le 190\text{ns} (FR1)$ | $\le 100\text{ns} (FR1)$ | | +| | 1PPS $\max TE_L $ | $\le 1100\text{ns}$ | $\le 1100\text{ns}$ | | +| | 1PPS $\max TE_{RL} $ | $\le 60\text{ns} (FR2)$<br>$\le 190\text{ns} (FR1)$ | $\le 100\text{ns} (FR1)$ | | +| | Frequency Limit (For PRTC Class-A) | $\le 32\text{ppb}$ | $\le 32\text{ppb}$ | | + +## 9.1.16 Network Time Synchronization-LLS-C3 (Option-B) configuration + +### (Time Error with Background Traffic) + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.16 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Frequency Error, Absolute Time Error, Relative Time Error at O-RU UNI with and without background traffic. LLS-C3 (Option-B) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI with and without background traffic.</li> <li>Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI with and without background traffic.</li> <li>Verify the Maximum Relative 1PPS Time Error (<math>\max TE_{RL} </math>) at O-RU UNI with and without background traffic.</li> <li>Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | PRTC/T-GM connected to GNSS simulator and ensure that T-GM is locked.<br>O-RU UNI is the measurement plane. | | | + +### Test Topology: + +![Test Topology Diagram showing the connection between various network elements for timing measurement. A central dashed circle contains T-GM, T-BC, HSR1, HSR2, CSR1, and CSR2. T-GM is connected to GNSS Simulator and Frequency Reference. T-BC is connected to T-GM. HSR1 and HSR2 are connected to T-BC. CSR1 and CSR2 are connected to T-BC. A Traffic Tester Background Traffic block is connected to HSR1, HSR2, CSR1, and CSR2. O-DU UNIs are connected to HSR1 and HSR2. O-RU UNIs are connected to CSR1 and CSR2. Clock Testers are connected to CSR1 and CSR2. Timing requirements are specified: |TE| ≤ 1100ns for O-DU UNI and O-RU UNI, and |TE| ≤ 100ns for T-GM, T-BC, HSR, and CSR. Performance targets for Enhanced RU (FR2-FR1) and Regular RU (FR1) are also listed.](4fdeda2d2c466b9fc167c17bced92fa9_img.jpg) + +Frequency Reference → GNSS Simulator → RF Signal → 1PPS Ref+10MHz Ref + +PRTC-A, |TE|≤100ns +PRTC-B, |TE|≤40ns +ePRTC, |TE|≤30ns + +O-DU UNI + +O-RU UNI + +1PPS out + +1PPS out + +For Enhanced RU(FR2-FR1) +Max |TE<sub>RL</sub>|=60-190ns at O-RU UNI +Max TAE=130-260ns + +For Regular RU(FR1) +Max |TE<sub>RL</sub>|=100ns at O-RU UNI +Max TAE=260ns + +|TE|≤1100ns + +|TE|≤1100ns + +Test Topology Diagram showing the connection between various network elements for timing measurement. A central dashed circle contains T-GM, T-BC, HSR1, HSR2, CSR1, and CSR2. T-GM is connected to GNSS Simulator and Frequency Reference. T-BC is connected to T-GM. HSR1 and HSR2 are connected to T-BC. CSR1 and CSR2 are connected to T-BC. A Traffic Tester Background Traffic block is connected to HSR1, HSR2, CSR1, and CSR2. O-DU UNIs are connected to HSR1 and HSR2. O-RU UNIs are connected to CSR1 and CSR2. Clock Testers are connected to CSR1 and CSR2. Timing requirements are specified: |TE| ≤ 1100ns for O-DU UNI and O-RU UNI, and |TE| ≤ 100ns for T-GM, T-BC, HSR, and CSR. Performance targets for Enhanced RU (FR2-FR1) and Regular RU (FR1) are also listed. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSR. + +### Test Configuration + +- Multiple Transport TNEs (HSR1, HSR2, CSR1, CSR2 and T-BC) connected and configured as shown in the Test Topology. +- Clock Tester at O-RU UNI receives timing input on its measurement port. +- Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +- Traffic Tester for emulating Background Traffic for the desired packet sizes and rate. +- Proper QoS configuration on TNEs to make sure PTP packets not congested in the network. +- G.8275.1 Full Timing Support profile. + +### Procedure: + +#### Case-1: Normal Scenario (with no background traffic) + +##### Detailed Test procedure: + +- Connect T-GM to GNSS Simulator and ensure that T-GM is locked. +- Configure O-DU as T-TSC, CSR1 and CSR2 as T-BCs. HSR1 and HSR2 as either T-BCs or T-TCs. +- Enable G.8275.1 profile on all transport TNEs (HSR, CSR and T-BC). +- Connect Clock tester measurement ports to CSRs TimeTransmitter port to monitor the PTP at O-RU UNI. +- Establish PTP and SyncE session to the fronthaul network. + +##### Verifications for Maximum Absolute Packet Time Error + +- Verify that PTP session is up and running between T-GM and CSR. +- Verify time error measurements using the Clock Tester for the PTP flows from CSR at the O-RU UNI. + +- a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) +- b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data $(\max TE1, \min TE1)$ and $(\max TE2, \min TE2)$ for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements on Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +#### **Case-2: With background traffic** + +##### **Detailed Test procedure:** + +1. Configure proper QoS on each of the TNEs so that PTP packets are not congested in the network. +2. Create traffic flows, especially the traffic types, rate and packet sizes should be as per FH requirements. (Refer the Section 7.2 in Xhaul Transport Requirements documents for details). + +3. Start traffic flows on all the Traffic Tester ports and make sure that no traffic loss observed. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that the PTP traffic is not dropped with background traffic. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI in presence of the Background traffic. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data $(\max TE1, \min TE1)$ and $(\max TE2, \min TE2)$ for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports in presence of the Background traffic. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TERL(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify 1PPS time error measurements on Clock Tester at the O-RU UNI in presence of the Background traffic. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the TimeTransmitter ports of CSR1 and CSR2 at O-RU UNI in presence of Background Traffic. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +| | | | | | +|----------------------------|--------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------|----------------| +| | | <p>NOTE1 (As per G.8271.1):<br/> To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | | | +| <b>Pass/Fail Criteria:</b> | | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified with and without background traffic. | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet max $ TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet max $ TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | 1PPS max $ TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS max $ TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +## 9.1.17 Network Time Synchronization-LLS-C3 (Option-B) configuration + +### (PTP Holdover test) + +| | | | | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.17 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Holdover performance test over LLS-C3 configuration | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at O-RU UNI.</li> <li>5. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | PRTC/T-GM connected to GNSS Simulator and locked.<br>O-RU UNI is the measurement plane. | | | + +### Test Topology: + +![Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, T-BC, HSR, CSR, O-DU, and Clock Testers. The diagram includes timing requirements for various components and a table for Enhanced and Regular RU timing.](4f7fb52c848c2202a5d1b1d4817edf44_img.jpg) + +The diagram illustrates the test topology for clock testing. A GNSS Simulator provides a 1PPS Ref+10MHz Ref signal to the T-GM. The T-GM is connected to the T-BC, which in turn connects to HSR1, HSR2, CSR1, and CSR2. The O-DU is connected to HSR1 and HSR2. The Clock Testers are connected to CSR1 and CSR2. The diagram includes timing requirements for various components: + +- PRTC-A, $|TE| \leq 100\text{ns}$ +- PRTC-B, $|TE| \leq 40\text{ns}$ +- ePRTC, $|TE| \leq 30\text{ns}$ +- $|TE| \leq 1100\text{ns}$ (for O-DU UNI) +- $|TE| \leq 1100\text{ns}$ (for O-RU UNI) + +| Configuration | Max $ TE_{RL} $ | Max TAE | +|--------------------------|----------------------|-----------| +| For Enhanced RU(FR2-FR1) | 60-190ns at O-RU UNI | 130-260ns | +| For Regular RU(FR1) | 100ns at O-RU UNI | 260ns | + +Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, T-BC, HSR, CSR, O-DU, and Clock Testers. The diagram includes timing requirements for various components and a table for Enhanced and Regular RU timing. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSR. + +### Test Configuration + +- Multiple Transport TNEs (HSR, HSR and CSRs) connected and configured as shown in the Test Topology. +- Clock Tester at O-RU UNI receives timing input on its measurement port. +- Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +- G8275.1 Full Timing Support profile + +### Procedure: + +#### **Case-1: Normal Scenario (GNSS connectivity to T-GM is Up)** + +##### **Detailed Test procedure:** + +- Connect T-GM to GNSS Simulator and ensure that T-GM is locked. +- Configure O-DU as T-TSC, CSR1 and CSR2 as T-BCs. HSR1 and HSR2 as either T-BCs or T-TCs. +- Enable G.8275.1 profile on all transport TNEs (HSR, CSR and T-BC). +- Connect Clock tester measurement ports to CSRs TimeTransmitter port to monitor PTP at the O-RU UNI. +- Establish PTP and SyncE session to the fronthaul network. + +##### **Verifications for Maximum Absolute Packet Time Error** + +- Verify that PTP session is up and running between T-GM and CSR. +- Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100\text{ns}$ (For Enhanced RU) + - $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100\text{ns}$ (For Regular RU) + +##### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $maxTE1, minTE1$ ) and ( $maxTE2, minTE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +#### **Case-2: GNSS Connectivity to T-GM Fails (Short-interruption for 5 min)** + +##### **Detailed Test procedure:** + +1. Simulate a Fault (Link down) between GNSS and T-GM for a short duration of 5 min. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that the T-GM moves to Phase Holdover and start advertising Clock Class=7. +2. Verify time error measurements on Clock Tester for the PTP flows from CSR at the O-RU UNI in while the T-GM is holdover. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU (Enhanced) UNI $\leq 1350ns$ + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU (Regular) UNI $\leq 1350ns$ + +| | | | | | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------|----------------| +| <p><b>Verifications for Maximum Relative Packet Time Error (NOTE1)</b></p> <ol style="list-style-type: none"> <li>1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data (<math>maxTE1, minTE1</math>) and (<math>maxTE2, minTE2</math>) for both O-RU UNI at least for a period of 1000sec.</li> <li>2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li>b. <math>\max TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li>c. <math>\max TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TE_{RL}(t)</math>, but to measure the maximum possible value it can take.</p> $\max TE_{RL} (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$ <p><b>Verifications for Maximum Absolute 1PPS Time Error</b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP session is up and running between T-GM and CSR.</li> <li>2. Verify 1PPS time error measurements on Clock Tester at the O-RU UNI. <ol style="list-style-type: none"> <li>a. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1350ns</math> (For Enhanced RU)</li> <li>b. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1350ns</math> (For Regular RU)</li> </ol> </li> </ol> <p><b>Verifications for Maximum Relative 1PPS Time Error</b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP and SyncE session is up and running.</li> <li>2. Estimate the Maximum Relative 1PPS Time Error measurements between the TimeTransmitter ports of CSR1 and CSR2 at O-RU UNI. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li>b. <math>\max TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li>c. <math>\max TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p><b>Verifications for Time Wander</b></p> <ol style="list-style-type: none"> <li>1. Verify the Time Wander using Clock tester at the O-RU UNI. <ol style="list-style-type: none"> <li>a. Frequency Limit is <math>\leq 32ppb</math> (For PRTC Class-A)</li> <li>b. MTIE mask as per the limit specified.</li> </ol> </li> </ol> | | | | | +| <b>Pass/Fail Criteria:</b> | | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Wander Limit measurement result remains under the limits for the entire holdover event, including the restoration. | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value (Normal Case) | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | + +| | | | | +|---------------------------------------|---------|---------|--| +| Frequency Limit<br>(For PRTC Class-A) | ≤ 32ppb | ≤ 32ppb | | +|---------------------------------------|---------|---------|--| + +### 9.1.18 Network Time Synchronization-LLS-C3 (Option-B) configuration (PTP Fail-over/redundancy test) + +| | | | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------| +| <b>Test ID</b> | SYNC.TE.18 | <b>Classification</b> | Synchronization, Performance, Time Error | +| <b>Test Title</b> | Failover performance test over LLS-C3 configuration | | | +| <b>Test Objective:</b> | Perform the below test at the O-RU UNI when GNSS to the Edge PRTC/T-GM is disconnected and backup timing from Network T-GM is switched over to maintain the synchronization: <ol style="list-style-type: none"> <li>Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at O-RU UNI.</li> <li>Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | Edge PRTC/T-GM connected to GNSS Simulator, and T-GM is locked.<br>Network T-GM connected to GNSS Simulator and locked.<br>O-RU UNI is the measurement plane. | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram" data-bbox="414 1265 1420 1870" src="c28d2122c857d0561366e8721ee7c70a_img.jpg"/> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSR.</p> | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>Multiple Transport TNEs (HSR1, HSR2, CSR1 and CSR2) connected and configured as shown in the Test Topology.</li> </ol> | | | + +| | | +|-------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>G8275.1 profile configured for primary and backup path providing Full Timing Support (FTS)</li> </ol> | +| <b>Procedure:</b> | <p><b><u>Case-1: Normal Scenario (GNSS connectivity to both GM is Up)</u></b></p> <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>Connect Edge PRTC/T-GM and Network T-GM to the GNSS Simulator and ensure both T-GMs locked.</li> <li>Enable network connectivity among T-GMs, CSRs and HSRs.</li> <li>Enable both Edge T-GM and Network T-GM with G.8275.1 profile.</li> <li>Establish PTP connection (G.8275.1) sessions at each of the TNEs.</li> <li>Configure Clock Tester for measurement profiles.</li> <li>Perform the Time error measurement.</li> </ol> <p><b><u>Verifications for Maximum Absolute Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify that PTP session is up and running between Edge T-GM and CSR.</li> <li>Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. <ol style="list-style-type: none"> <li><math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Enhanced RU)</li> <li><math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error (NOTE1)</u></b></p> <ol style="list-style-type: none"> <li>Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data (<math>\max TE1, \min TE1</math>) and (<math>\max TE2, \min TE2</math>) for both O-RU UNI at least for a period of 1000sec.</li> <li>Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li><math>\max TE_{RL} (1,2) \leq 60\text{ns}</math> (FR2) (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 190\text{ns}</math> (FR1) (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 100\text{ns}</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TE_{RL}(t)</math>, but to measure the maximum possible value it can take.</p> $\max TE_{RL} (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$ <p><b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify that PTP session is up and running between T-GM and CSR.</li> <li>Verify the 1PPS time error measurements on Clock Tester at the O-RU UNI. <ol style="list-style-type: none"> <li><math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Enhanced RU)</li> <li><math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative 1PPS Time Error</u></b></p> | + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +#### **Case-2: GNSS Connectivity to Edge T-GM Fails** + +##### **Detailed Test procedure:** + +1. Disconnect GNSS Simulator connection to Edge PRTC/T-GM and switch the Timing source to Network T-GM. +2. Monitor and log the Time Error at specified time interval. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that the Edge T-GM moves to Phase Holdover and start advertising Clock Class=7 and CSR recover clock from Network T-GM via FTS network based on A-BTCA. + +Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI in while the Edge T-GM is in holdover. + +- a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) +- b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify 1PPS time error measurements on Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + +| | | | | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------|--------------------|----------------| +| | <p>b. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100ns</math> (For Regular RU)</p> <p><b>Verifications for Maximum Relative 1PPS Time Error</b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP and SyncE session is up and running.</li> <li>2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li>b. <math>\max TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li>c. <math>\max TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p><b>Verifications for Time Wander</b></p> <ol style="list-style-type: none"> <li>1. Verify the Time Wander using Clock tester at the O-RU UNI. <ol style="list-style-type: none"> <li>a. Frequency Limit is <math>\leq 32ppb</math> (For PRTC Class-A)</li> <li>b. MTIE mask as per the limit specified.</li> </ol> </li> </ol> | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value<br>(For Enhanced RU)      (For Regular RU) | | Observed Value | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2)<br>$\leq 190ns$ (FR1) | $\leq 100ns$ (FR1) | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2)<br>$\leq 190ns$ (FR1) | $\leq 100ns$ (FR1) | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +1 + +2 + +## 9.1.19 Network Time Synchronization-LLS-C3 (Option-C) configuration + +| | | | | +|------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.19 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Frequency Error, Absolute Time Error, Relative Time Error at O-RU UNI. LLS-C3 (Option-C) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>\max TE_{RL} </math>) at O-RU UNI.</li> <li>5. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <p>T-GM is placed either in the Midhaul or Backhaul.</p> <p>T-GM/PRTC connected to GNSS Simulator, and T-GM is locked.</p> <p>O-RU UNI is the measurement plane.</p> | | | + +## Test Topology: + +![Test Topology Diagram showing the connection between a Frequency Reference, GNSS Simulator, T-GM, O-DU UNI, O-RU UNI, and Clock Testers. The diagram illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSR. The diagram includes various transport TNEs (HSR, HSR-B and CSRs) connected and configured as shown in the Test Topology. The diagram also shows the connection of the Clock Tester at O-RU UNI to the CSRs TimeTransmitter port to monitor PTP at the O-RU UNI. The diagram includes timing requirements: |TE| ≤ 1100ns, ±30-95ns → ±50ns (FR2-FR1) → (FR1), and |TE| ≤ 1100ns. The diagram also shows the connection of the Clock Tester at O-RU UNI to the CSRs TimeTransmitter port to monitor PTP at the O-RU UNI. The diagram includes timing requirements: |TE| ≤ 1100ns, ±30-95ns → ±50ns (FR2-FR1) → (FR1), and |TE| ≤ 1100ns. The diagram also shows the connection of the Clock Tester at O-RU UNI to the CSRs TimeTransmitter port to monitor PTP at the O-RU UNI. The diagram includes timing requirements: |TE| ≤ 1100ns, ±30-95ns → ±50ns (FR2-FR1) → (FR1), and |TE| ≤ 1100ns.](3a36142be9c4750b8396bcb25f1138b3_img.jpg) + +Test Topology Diagram showing the connection between a Frequency Reference, GNSS Simulator, T-GM, O-DU UNI, O-RU UNI, and Clock Testers. The diagram illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSR. The diagram includes various transport TNEs (HSR, HSR-B and CSRs) connected and configured as shown in the Test Topology. The diagram also shows the connection of the Clock Tester at O-RU UNI to the CSRs TimeTransmitter port to monitor PTP at the O-RU UNI. The diagram includes timing requirements: |TE| ≤ 1100ns, ±30-95ns → ±50ns (FR2-FR1) → (FR1), and |TE| ≤ 1100ns. The diagram also shows the connection of the Clock Tester at O-RU UNI to the CSRs TimeTransmitter port to monitor PTP at the O-RU UNI. The diagram includes timing requirements: |TE| ≤ 1100ns, ±30-95ns → ±50ns (FR2-FR1) → (FR1), and |TE| ≤ 1100ns. The diagram also shows the connection of the Clock Tester at O-RU UNI to the CSRs TimeTransmitter port to monitor PTP at the O-RU UNI. The diagram includes timing requirements: |TE| ≤ 1100ns, ±30-95ns → ±50ns (FR2-FR1) → (FR1), and |TE| ≤ 1100ns. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference connected to clock tester. The tester measurement ports at O-RU UNI connected to the CSR. + +## Test Configuration + +1. Multiple Transport TNEs (HSR, HSR-B and CSRs) connected and configured as shown in the Test Topology. +2. Clock Tester at O-RU UNI receives timing input on its measurement port. +3. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +4. G8275.1 profile for primary and G8275.2 profile for backup and provides partial timing support. + +## Procedure: + +### Detailed Test procedure: + +1. Connect T-GM to GNSS Simulator and ensure that T-GM is locked. +2. Configure O-DU as T-TSC, CSR1 and CSR2 as T-BCs. HSR1 and HSR2 as either T-BCs or T-TCs. +3. Enable G.8275.1 profile on all transport TNEs (HSR, CSR and T-BC). +4. Connect Clock tester measurement ports to CSRs TimeTransmitter port to monitor PTP at the O-RU UNI. +5. Establish PTP and SyncE session to the fronthaul network. + +### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +### Verifications for Maximum Relative Packet Time Error (NOTE1) + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + +- b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) +- c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### Verifications for Maximum Absolute 1PPS Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements on Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### Verifications for Maximum Relative 1PPS Time Error + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### Verifications for Time Wander + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1: + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### **Pass/Fail Criteria:** + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Wander Limit measurement result is below the limit specified. + +#### **Test Output** + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|---------------------------------------------|--------------------|--------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| Frequency Limit (If PRTC is Class-A device) | $\leq 32ppb$ | $\leq 32ppb$ | | + +## 9.2 Timing Solution & Resiliency in Ring Topology (LLS-C3) + +This chapter delivers the testing methodologies, parameters and performance limits for PTP-based network technologies in normal and fail-over or rearrangement scenarios of T-GM and TNEs across various network segments in the LLS-C3 configurations. The chapter is organized in different sections each representing a typical synchronization configuration mode. For each mode, all related metrics are identified, and limits are provided to deliver pass/fail verdicts. + +Various synchronization resiliency options have been defined in the O-RAN WG9 Synchronization Architecture and Solution Specification. Depending on the specific O-RAN deployment being considered, not all of them might be relevant. When testing the S-Plane, the System Integrator shall identify which of the test cases are relevant depending on the specific deployment scenarios addressed. + +Following high level options have been covered in this chapter and each of these options, clock advertisements and performance limits are discussed for normal and failover scenarios for T-GMs and TNEs in Backhaul, Midhaul and Fronthaul network segments in LLS-C3 configuration. Also scenarios like Asymmetry and Passive Port Monitoring are covered. + +1. Ring topology in Midhaul and Backhaul (LLS-C3 Configuration) + - a. O-DU connected to HSR and SYNC from Backhaul. + - b. O-DU connected to HSR and SYNC from Backhaul. (Aggregated Link) + - c. O-DU connected to CSR and SYNC from Backhaul. +2. Ring topology in Midhaul and Backhaul (LLS-C3 Configuration) + - a. O-DU connected to HSR and SYNC from Midhaul. + - b. O-DU connected to HSR and SYNC from Midhaul. (Aggregated Link) + - c. O-DU connected to CSR and SYNC from Midhaul. + +It is important to note that, though Passive Port Monitoring is an OPTIONAL feature in ITU-T G.8275.1 ANNEX-G, if implemented, it is necessary for the equipment to conform to the requirement as per the specifications. + +For PTP rearrangement scenarios like member-link failover in Aggregated Ethernet Bundle and for other failover scenarios, operator can make choice based on the vendor TNE capability to estimate the end-to-end clock performance limit. However, the performance limits specified in this chapter applicable for both normal and rearrangement scenarios. + +The test cases apply to both lab and field deployment cases. For lab cases, the type and number of inserted Transport Node Elements (TNE) will be determined by operators (or any other applicable end customer). The tests are performed at Xhaul UNI interfaces, and not between individual TNEs. The Xhaul UNI interfaces include O-RU Fronthaul UNI, O-DU Fronthaul or Midhaul UNI. + +1PPS test at O-RU UNI is typically used for debugging and monitoring the packet layer performance of the nearest TNE in the fronthaul. The intention of such test is that if the TNE vendor implemented the 1PPS interface, the 1PPS error measured on such interface at the O-RU UNI should be a reflection of the output time error of TNE. Operator shall pay attention to an unacceptably large deviation of 1PPS error, beyond the limits specified, which may indicate an incorrect behaviour of TNEs. + +The Test Topologies in all the test cases uses GNSS simulator to generate the GNSS signal to the network PRTC/T-GM. This high-quality reference from the simulator is used as the external reference for clock testers as well. The resultant accuracy of this method is a few nanoseconds. However, one can also use a GNSS signal feeding both the initial PRTC/T-GM in the network and the reference clock generating a 1pps/10MHz used to synchronize the clock testers for the measurements. Operator can make an allowance in this case, for all of the measurements for the accuracy of the reference. The magnitude of this allowance will depend on the specific GNSS reference in use. + +For relative time error measurements at UNI (e.g., O-RU Fronthaul UNI) this document uses the metric $\max|TE_{RL}|(1,2)$ as defined in [88], Appendix XI. Please note this metric represents an estimation and the worst-case scenario. Tests that meet (are below) the limits are seen as PASS. Tests not meeting this metric may still be acceptable. The decision is for operators to make. However, if the measurement equipment support relative time error measurement, operator can use such equipment. Refer ITU-T G.8271.1 Appendix XI for more details. + +For Frequency Limit at UNI (e.g., O-RU Fronthaul UNI) this document uses the metric defined as per WG4 section H.2 based on PRTC class for LLS-C3 configuration. Applicable MTIE limit shall apply for Frequency as per WG4 specification. + +The acceptable limits in all the below tests shall meet CUS specification worst case limits based on the maximum network size, but operator “should” apply the limits more aligned with the real tested configuration based on the network size. + +### 9.2.1 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Normal State (Case-1: T-GM1 is the preferred GM) + +| Test ID | SYNC.RE.01 | Classification | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------------------| +| Test Title | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Normal State without any Fail-over conditions exist (Case-1: T-GM1 is the preferred GM) | | | +| Test Objective: | <ol style="list-style-type: none"> <li>Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>Verify the Maximum Absolute Packet Time Error (<math>\text{Max} TE_L </math>) at O-RU UNI.</li> <li>Verify the Maximum Relative Packet Time Error (<math>\text{Max} TE_{RL} </math>) between two O-RU UNI ports.</li> <li>Verify the Maximum Absolute 1PPS Time Error (<math>\text{Max} TE_L </math>) at O-RU UNI.</li> <li>Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| Pre-Req | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> </ul> | | | + +O-RAN.WG9.XTRP-TST.0-R004-v05.00 + +✓ Priority-2 on T-GM1=1 and T-GM2=2. + +**Test Topology:** + +Image: Test Topology Diagram + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. + +**Test Configuration** + +1. Clock Tester at O-RU UNI receives timing input on its measurement port. +2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +3. G.8275.1 Full Timing Support profile. + +**Procedure:** +**Detailed Test procedure:** + +1. Connect both T-GMs to GNSS Simulator. +2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile. +3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +**Verifications for Clock Advertisements** + +1. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +**Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\le 1100\text{ns}$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\le 1100\text{ns}$ (For Regular RU) + +**Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}| (1,2) \le 60\text{ns}$ (FR2) (For Enhanced RU) + + © 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 176 + +- b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) +- c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +**Pass/Fail Criteria:** Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. + +| Test Output | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|-------------|--------------------------------------|-----------------------------------------|--------------------|----------------| +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2)<br>$\leq 190ns$ (FR1) | $\leq 100ns$ (FR1) | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2)<br>$\leq 190ns$ (FR1) | $\leq 100ns$ (FR1) | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +The above limits applicable for both Normal and Re-arrangement scenarios. + +## 9.2.2 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-T-GM1 to BR1 Link Down. (Case-1: T-GM1 is the preferred GM) + +| | | | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.02 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-T-GM1 to BR1 Link Down. (Case-1: T-GM1 is the preferred GM) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> <li>✓ Priority-2 on T-GM1=1 and T-GM2=2.</li> <li>✓ Test 9.2.1 MUST PASS.</li> </ul> | | | +| <b>Test Topology:</b> | <p>Image: Test Topology Diagram: A complex network diagram showing the test setup. It includes a central 'Ring2 Mid-haul' and 'Ring1 Back-haul'. Components include CSRs (Cell Site Routers), HSRs (Hub Site Routers), BRs (Backhaul Routers), O-DUs (Open Distributed Units), T-GMs (Timing and Synchronization Managers), and a Clock Tester. The diagram shows connections for PTP (Precision Time Protocol), SYNC (Synchronization), and Standby. A legend at the bottom right defines the components: BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router. A note at the bottom left states: 'The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.' Another note at the bottom left states: 'Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.'</p> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. As per Test 9.2.1.</li> <li>2. Fail the link between T-GM1 and BR1.</li> </ol> | | | + +## Procedure: + +### Detailed Test procedure: + +1. Connect both T-GMs to GNSS Simulator. +2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile. +3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +### Verifications for Clock Advertisements + +1. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +### Verifications for Maximum Relative Packet Time Error (NOTE1) + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +### Verifications for Maximum Absolute 1PPS Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +### Verifications for Maximum Relative 1PPS Time Error + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + +| | | | | | +|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------|-----------------------------------------|--------------------|-----------------------| +| b. $\max TE_{RL} (1,2) \leq 190ns$ (FR1) (For Enhanced RU)<br>c. $\max TE_{RL} (1,2) \leq 100ns$ (FR1) (For Regular RU)<br><b>Verifications for Time Wander</b><br>1. Verify the Time Wander using Clock tester at the O-RU UNI.<br>a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A)<br>b. MTIE mask as per the limit specified.<br>NOTE1 (As per G.8271.1):<br>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. | | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | <b>End-to-End Network Limit at O-RU UNI</b> | <b>Expected Value</b> | | <b>Observed Value</b> | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2)<br>$\leq 190ns$ (FR1) | $\leq 100ns$ (FR1) | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2)<br>$\leq 190ns$ (FR1) | $\leq 100ns$ (FR1) | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | +| | The above limits applicable for both Normal and Re-arrangement scenarios. | | | | + +## 9.2.3 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-T-GM1 Fail-over. (Case-1: T-GM1 is the preferred GM) + +| | | | | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.03 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-T-GM1 Fail-over. (Case-1: T-GM1 is the preferred GM) | | | +| <b>Test Objective:</b> | 1. Verify the Clock Lock states on BRs, HSRs and CSRs.<br>2. Verify the clock advertisements on BRs, HSRs and CSRs.<br>3. Verify the Maximum Absolute Packet Time Error ( $\max TE_L $ ) at O-RU UNI.<br>4. Verify the Maximum Relative Packet Time Error ( $\max TE_{RL} $ ) between two O-RU UNI ports.<br>5. Verify the Maximum Absolute 1PPS Time Error ( $\max TE_L $ ) at O-RU UNI.<br>6. Verify the Time Wander at the O-RU UNI. | | | +| <b>Pre-Req</b> | ✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.<br>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID. | | | + +- ✓ Priority-2 on T-GM1=1 and T-GM2=2. +- ✓ Test 9.2.1 MUST PASS. + +### Test Topology: + +![Test Topology Diagram showing a network architecture with various components and connections.](e97f0e6390a73b17968f1a103483fa17_img.jpg) + +The diagram illustrates a test topology for clock synchronization. It features a central 'Ring2 Mid-haul' and a 'Ring1 Back-haul'. Key components include: + + +- CSRs (Cell Site Routers):** CSR1 and CSR2, each with a TimeTransmitter (TT) and TimeReceiver (T-BC/eEEC) port. +- HSRs (Hub Site Routers):** HSR1, HSR2, HSR3, and HSR4, each with a TimeReceiver (T-BC/eEEC) port. +- BRs (Backhaul Routers):** BR1, BR2, BR3, and BR4, each with a TimeReceiver (T-BC/eEEC) port. +- O-DUs (Open Distributed Units):** O-DU1 and O-DU2, connected to the HSRs. +- T-GMs (Time Generator Monitors):** T-GM1 and T-GM2, connected to the BRs. +- Clock Tester:** Connected to the CSRs via O-RU UNI ports. +- GNSS Simulator:** Connected to T-GM1 and T-GM2. +- Frequency Reference:** Connected to T-GM1 and T-GM2. + + Connections are shown with various line styles: solid orange for PTP, dashed green for SYNC, and dotted blue for Standby. A legend at the bottom right identifies the components: BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router. A note at the top right indicates '1PPS Ref + 10MHz Ref'. + +Test Topology Diagram showing a network architecture with various components and connections. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. + +Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message. + +### Test Configuration + +1. As per Test 9.2.1. +2. Fail the link between T-GM1 to BR1 and BR2 OR Power OFF the T-GM1. + +### Procedure: + +#### Detailed Test procedure: + +1. Connect both T-GMs to GNSS Simulator. +2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile. +3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +#### Verifications for Clock Advertisements + +1. Verify that BR1 shall select clock from T-GM1 via BR2. +2. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +3. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +#### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### Verifications for Maximum Relative Packet Time Error (NOTE1) + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $maxTE1, minTE1$ ) and ( $maxTE2, minTE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +| | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------|--------------------|--------------------|----------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | + +| | | | | | +|---------------------------------------------------------------------------|-----------------------------------|-------------------|--------------|--| +| | | $\leq 190ns(FR1)$ | | | +| | Frequency Limit<br>(PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | +| The above limits applicable for both Normal and Re-arrangement scenarios. | | | | | + +## 9.2.4 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Ring Fail-over in Backhaul. (Case-1: T-GM1 is the preferred GM) + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.04 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Ring Fail-over in Backhaul. (Case-1: T-GM1 is the preferred GM) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> <li>✓ Priority-2 on T-GM1=1 and T-GM2=2.</li> <li>✓ Test 9.2.1 MUST PASS.</li> </ul> | | | +| <b>Test Topology:</b> | <p>Image: Test Topology Diagram: A complex network diagram showing a ring topology for timing resiliency. It includes O-DU1 and O-DU2 connected to HSRs (HSR1, HSR2, HSR3, HSR4) and BRs (BR1, BR2, BR3, BR4). The diagram also shows CSRs (CSR1, CSR2), T-GM1, T-GM2, a Clock Tester, and a Frequency Reference. Various connections are labeled with TT (Time Transmitter) and ST (Stateful). A legend at the bottom right defines the components: BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router. A legend at the bottom center defines the connection types: PTP (orange), SYNC (green), and Standby (dashed green).</p> | | | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>As per Test 9.2.1.</li> <li>Fail the link between BR1 and BR3.</li> </ol> | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>Connect both T-GMs to GNSS Simulator.</li> <li>Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile.</li> <li>Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI.</li> </ol> <p><b><u>Verifications for Clock Advertisements</u></b></p> <ol style="list-style-type: none"> <li>Verify that BR1 shall select clock from T-GM1 via BR2.</li> <li>Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned.</li> <li>Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3.</li> </ol> <p><b><u>Verifications for Maximum Absolute Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify that PTP session is up and running between T-GM and CSR.</li> <li>Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. <ol style="list-style-type: none"> <li><math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Enhanced RU)</li> <li><math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error (NOTE1)</u></b></p> <ol style="list-style-type: none"> <li>Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data (<math>\max TE1, \min TE1</math>) and (<math>\max TE2, \min TE2</math>) for both O-RU UNI at least for a period of 1000sec.</li> <li>Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li><math>\max TE_{RL} (1,2) \leq 60\text{ns}</math> (FR2) (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 190\text{ns}</math> (FR1) (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 100\text{ns}</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TE_{RL}(t)</math>, but to measure the maximum possible value it can take.</p> $\max TE_{RL} (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$ <p><b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify that PTP session is up and running between T-GM and CSR.</li> <li>Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI.</li> </ol> | + +- a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) +- b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +| | | | | | +|---------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------|-----------------------|--------------------|-----------------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | <b>End-to-End Network Limit at O-RU UNI</b> | <b>Expected Value</b> | | <b>Observed Value</b> | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | +| The above limits applicable for both Normal and Re-arrangement scenarios. | | | | | + +1 + +2 9.2.5 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from + +3 Backhaul (LLS-C3)-Ring Fail-over in Midhaul. (Case-1: T-GM1 is the + +4 preferred GM) + +| | | | | +|-------------------|------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.05 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Ring Fail-over in Midhaul. (Case-1: T-GM1 is the preferred GM) | | | + +| | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | +| <b>Pre-Req</b> | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> <li>✓ Priority-2 on T-GM1=1 and T-GM2=2.</li> <li>✓ Test 9.2.1 MUST PASS.</li> </ul> | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A network diagram showing the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. The diagram includes components like CSRs, HSRs, BRs, O-DUs, T-GMs, and a Clock Tester. It also shows Ring1 Back-haul and Ring2 Mid-haul connections. A legend defines BR as Backhaul Router, HSR as Hub Site Router, and CSR as Cell Site Router. A note indicates 1PPS Ref + 10MHz Ref." data-bbox="422 779 1420 1288" src="2a1e11e72514e1c921f1644e65f39059_img.jpg"/> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. As per Test 9.2.1.</li> <li>2. Fail the link between BR1 and BR3.</li> </ol> | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect both T-GMs to GNSS Simulator.</li> <li>2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile.</li> <li>3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI.</li> </ol> <p><b>Verifications for Clock Advertisements</b></p> <ol style="list-style-type: none"> <li>1. Verify that BR1 shall select clock from T-GM1 via BR2.</li> <li>2. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned.</li> <li>3. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3.</li> </ol> | + +### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}| (1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}| (1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}| (1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}| (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}| (1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}| (1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}| (1,2) \leq 100ns$ (FR1) (For Regular RU) + +### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +| | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------|-----------------------|-----------------------|----------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet max $TE_L$ | ≤ 1100ns | ≤ 1100ns | | +| | Packet max $TE_{RL}$ | ≤ 60ns( <i>FR2</i> ) | ≤ 100ns( <i>FR1</i> ) | | +| | | ≤ 190ns( <i>FR1</i> ) | | | +| | 1PPS max $TE_L$ | ≤ 1100ns | ≤ 1100ns | | +| | 1PPS max $TE_{RL}$ | ≤ 60ns( <i>FR2</i> ) | ≤ 100ns( <i>FR1</i> ) | | +| | | ≤ 190ns( <i>FR1</i> ) | | | +| | Frequency Limit (PRTC Class-A) | ≤ 32ppb | ≤ 32ppb | | +| | The above limits applicable for both Normal and Re-arrangement scenarios. | | | | + +## 9.2.6 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Ring Fail-over in Fronthaul. (Case-1: T-GM1 is the preferred GM) + +| | | | | +|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.06 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Ring Fail-over in Fronthaul. (Case-1: T-GM1 is the preferred GM) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> <li>✓ Priority-2 on T-GM1=1 and T-GM2=2.</li> <li>✓ Test 9.2.1 MUST PASS.</li> </ul> | | | + +## Test Topology: + +![Test Topology Diagram showing a network architecture with various components and connections.](46195dedae416fd1e2c032ccc57aad8b_img.jpg) + +The diagram illustrates a test topology for clock synchronization. It features several key components and their interconnections: + +- Central Core:** Consists of two rings, Ring1 (Back-haul) and Ring2 (Mid-haul). Ring1 connects Backhaul Routers (BR1, BR2, BR3, BR4). Ring2 connects Hub Site Routers (HSR1, HSR2, HSR3, HSR4). +- Cell Site Routers (CSRs):** Two CSRs (CSR1, CSR2) are connected to the HSRs. CSR1 is connected to HSR3 and HSR4. CSR2 is connected to HSR1 and HSR2. +- Time Transmitters (TTs) and Stateful (ST) Ports:** Each CSR and HSR contains a TT and ST port. The ST ports are connected to the TTs. +- Measurement Plane:** A Clock Tester is connected to the TTs of CSR1 and CSR2 via O-RU UNI ports. The Clock Tester is also connected to a GNSS Simulator and a Frequency Reference. +- Legend:** + - TT: Time Transmitter + - ST: Stateful + - BR: Backhaul Router + - HSR: Hub Site Router + - CSR: Cell Site Router + - PTP: Precision Time Protocol + - SYNCE: Synchronization + - Standby: Standby state + +Test Topology Diagram showing a network architecture with various components and connections. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. + +Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message. + +## Test Configuration + +- As per Test 9.2.1. +- Fail the link between HSR3 and CSR1. + +## Procedure: + +### Detailed Test procedure: + +- Connect both T-GMs to GNSS Simulator. +- Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile. +- Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +### Verifications for Clock Advertisements + +- Verify that BR1 shall select clock from T-GM1 via BR2. +- Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +- Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +### Verifications for Maximum Absolute Packet Time Error + +- Verify that PTP session is up and running between T-GM and CSR. +- Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\le 1100\text{ns}$ (For Enhanced RU) + - $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\le 1100\text{ns}$ (For Regular RU) + +### Verifications for Maximum Relative Packet Time Error (NOTE1) + +- Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +- Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + +- a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) +- b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) +- c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### **Pass/Fail Criteria:** + +Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. + +#### **Test Output** + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|--------------------|--------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +The above limits applicable for both Normal and Re-arrangement scenarios. + +## 9.2.7 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Asymmetry Test (Case-1: T-GM1 is the preferred GM) + +| | | | | +|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.07 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Asymmetry Test. (Case-1: T-GM1 is the preferred GM) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> <li>✓ Priority-2 on T-GM1=1 and T-GM2=2.</li> </ul> | | | +| <b>Test Topology:</b> | <p>Image: Test Topology Diagram: A ring topology showing two rings, Ring1 Back-haul and Ring2 Mid-haul. Ring1 connects Backhaul Routers (BR1, BR2, BR3, BR4, BR5, BR6) and Ring2 connects Hub Site Routers (HSR1, HSR2, HSR3, HSR4). Cell Site Routers (CSR1, CSR2) are connected to O-DU1 and O-DU2 respectively. A Clock Tester is connected to CSRs. Time Transmitters (TT) and Stateful (ST) ports are shown for various components. A GNSS Simulator provides 1PPS and 10MHz references to T-GM1 and T-GM2, which are connected to the network via Frequency Reference.</p> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. As per Test 9.2.1.</li> <li>2. Introduce Asymmetry of +1000ns at the O/p of T-GM1 and No Asymmetry at the O/p of T-GM2.</li> </ol> | | | + +| | | +|------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | 3. Configure Asymmetry Compensation of +1000ns on BR1 and BR2 | +| Procedure: | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect both T-GMs to GNSS Simulator.</li> <li>2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile.</li> <li>3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI.</li> </ol> <p><b><u>Verifications for Clock Advertisements</u></b></p> <ol style="list-style-type: none"> <li>1. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned.</li> <li>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3.</li> </ol> <p><b><u>After Step-2 of Test Configurations</u></b></p> <p><b><u>Verifications for Maximum Absolute Packet Time Error and 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify Performance Measurement during steady state. (1PPS and Packet Time Error should show an additional Error of +/-500ns due to Asymmetry)</li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error (NOTE1)</u></b></p> <ol style="list-style-type: none"> <li>1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data <math>(maxTE1, minTE1)</math> and <math>(maxTE2, minTE2)</math> for both O-RU UNI at least for a period of 1000sec.</li> <li>2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \le 60ns</math> (FR2) (For Enhanced RU)</li> <li>b. <math>\max TE_{RL} (1,2) \le 190ns</math> (FR1) (For Enhanced RU)</li> <li>c. <math>\max TE_{RL} (1,2) \le 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TE_{RL}(t)</math>, but to measure the maximum possible value it can take.</p> $\max TE_{RL} (1,2) \text{ the greatest of } \begin{cases} (maxTE_L(1) - minTE_L(2)) \\ (maxTE_L(2) - minTE_L(1)) \end{cases}$ <p><b><u>Verifications for Maximum Relative 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP and SyncE session is up and running.</li> <li>2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \le 60ns</math> (FR2) (For Enhanced RU)</li> <li>b. <math>\max TE_{RL} (1,2) \le 190ns</math> (FR1) (For Enhanced RU)</li> <li>c. <math>\max TE_{RL} (1,2) \le 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Time Wander</u></b></p> <ol style="list-style-type: none"> <li>1. Verify the Time Wander using Clock tester at the O-RU UNI. <ol style="list-style-type: none"> <li>a. Frequency Limit is <math>\le 32ppb</math> (For PRTC Class-A)</li> <li>b. MTIE mask as per the limit specified.</li> </ol> </li> </ol> <p>NOTE1 (As per G.8271.1):</p> <p>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | + +| | | | | | | +|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------|------------------------------------------------------|-------------------|----------------|--| +| <b>After Step-3 of Test Configurations</b><br><b>Verifications for Maximum Absolute Packet Time Error and 1PPS Time Error</b><br>1. Verify Performance Measurement during steady state. (1PPS and Packet Time Error shouldn't show any additional Error of +/-500ns due to Asymmetry)<br><b>Verifications for Maximum Relative Packet Time Error and 1PPS Time Error</b><br>1. Verify the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. The results should be as per Test 9.2.1. | | | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value<br>(For Enhanced RU) (For Regular RU) | | Observed Value | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | | +| | Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | | +| | | $\leq 190ns(FR1)$ | | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | | +| | | $\leq 190ns(FR1)$ | | | | +| Frequency Limit (PRTC Class-A) | | $\leq 32ppb$ | $\leq 32ppb$ | | | +| The above limits for $\max TE_L $ doesn't include the error due to Manual Asymmetry. | | | | | | + +1 + +## 9.2.8 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Asymmetry Test with Link-Fail. (Case-1: T-GM1 is the preferred GM) + +4 + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.08 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Asymmetry Test with Link-Fail. (Case-1: T-GM1 is the preferred GM) | | | +| <b>Test Objective:</b> | 1. Verify the Clock Lock states on BRs, HSRs and CSRs.<br>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs.<br>3. Verify the Maximum Absolute Packet Time Error ( $\max TE_L $ ) at O-RU UNI.<br>4. Verify the Maximum Relative Packet Time Error ( $\max TE_{RL} $ ) between two O-RU UNI ports.<br>5. Verify the Maximum Absolute 1PPS Time Error ( $\max TE_L $ ) at O-RU UNI.<br>6. Verify the Time Wander at the O-RU UNI. | | | +| <b>Pre-Req</b> | ✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.<br>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.<br>✓ Priority-2 on T-GM1=1 and T-GM2=2. | | | + +## Test Topology: + +![Test Topology Diagram showing a network architecture with various components and connections.](d72e3817bfa42303b4c3d3039e007256_img.jpg) + +The diagram illustrates a test topology for O-RAN. It features a central 'Ring2 Mid-haul' and a 'Ring1 Back-haul'. Key components include: + +- CSRs (Cell Site Routers):** CSR1 and CSR2, each with a T-BC/eEC port and a TT (TimeTransmitter) port. +- HSRs (Hub Site Routers):** HSR1, HSR3, HSR4, and HSR2, each with a T-BC/eEC port and a TT port. +- BRs (Backhaul Routers):** BR1, BR2, BR3, and BR4, each with a T-BC/eEC port and a TT port. +- O-DUs (Open Distributed Units):** O-DU1 and O-DU2, each with a T-TSC/eEC port and a TT port. +- T-GMs (Time Generator Modules):** T-GM1 and T-GM2, connected to a GNSS Simulator and a Frequency Reference. +- Clock Tester:** Connected to CSR1 and CSR2 via O-RU UNI ports. +- Legend:** + - TT: TimeTransmitter + - ST: Stateful + - PTP: Precision Time Protocol + - SYNCE: Synchronous + - Standby: Standby + - BR: Backhaul Router + - HSR: Hub Site Router + - CSR: Cell Site Router + +Test Topology Diagram showing a network architecture with various components and connections. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. + +Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message. + +## Test Configuration + +1. Pre-condition-Test 9.2.7 Configuration. +2. Remove the configured Asymmetry Compensation of +1000ns on BR1 and BR2 in TEST-7. +3. Fail the link between BR1 and T-GM1 and BR2 and T-GM1. + +## Procedure: + +### Detailed Test procedure: + +1. Connect both T-GMs to GNSS Simulator. +2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile. +3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +### Verifications for Clock Advertisements + +1. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +### After Step-3 of Test Configurations + +### Verifications for Maximum Absolute Packet Time Error and 1PPS Time Error + +1. Verify Performance Measurement during steady state. (1PPS and Packet Time Error should show an additional Error of +/-500ns due to Asymmetry) + +### Verifications for Maximum Relative Packet Time Error (NOTE1) + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $maxTE1$ , $minTE1$ ) and ( $maxTE2$ , $minTE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + +- c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +#### **After Step-3 of Test Configurations** + +#### **Verifications for Maximum Absolute Packet Time Error and 1PPS Time Error** + +1. Verify Performance Measurement during steady state. (1PPS and Packet Time Error shouldn't show any additional Error of +/-500ns due to Asymmetry) + +#### **Verifications for Maximum Relative Packet Time Error and 1PPS Time Error** + +1. Verify the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. The results should be as per Test 9.2.1. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +**Pass/Fail Criteria:** Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. + +| Test Output | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|-------------|--------------------------------------|--------------------|--------------------|----------------| +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +The above limits for $\max|TE_L|$ doesn't include the error due to Manual Asymmetry. + +## 9.2.9 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Aggregated Link (Case-1: T-GM1 is the preferred GM) + +| | | | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.09 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Aggregated Link. (Case-1: T-GM1 is the preferred GM) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> <li>✓ Priority-2 on T-GM1=1 and T-GM2=2.</li> </ul> | | | +| <b>Test Topology:</b> | <p>Image: Test Topology Diagram: A ring topology for timing resiliency. It shows two rings: Ring1 Back-haul and Ring2 Mid-haul. Ring1 connects Backhaul Routers (BR1, BR2, BR3, BR4) and Hub Site Routers (HSR1, HSR2, HSR3, HSR4). Ring2 connects Hub Site Routers (HSR1, HSR2, HSR3, HSR4) and O-DUs (O-DU1, O-DU2). Cell Site Routers (CSR1, CSR2) are connected to O-DUs. A Clock Tester is connected to CSRs. Timing sources T-GM1 and T-GM2 are connected to BRs. A GNSS Simulator provides a 1PPS and 10MHz reference to the Clock Tester. Legend: TT: TimeTransmitter, ST: Stateful, PTP: SYNC, LAG: Link Aggregation Group (Primary/Secondary), BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router.</p> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>3. G.8275.1 Full Timing Support profile.</li> </ol> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect both T-GMs to GNSS Simulator.</li> </ol> | | | + +2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile over Aggregated Link in backhaul and midhaul. +3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +#### **Verifications for Clock Advertisements** + +1. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}| (1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}| (1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}| (1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}| (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}| (1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}| (1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}| (1,2) \leq 100ns$ (FR1) (For Regular RU) + +### Verifications for Time Wander + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +### Pass/Fail Criteria: + +Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. + +### Test Output + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|-------------------|-------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +The above limits applicable for both Normal and Re-arrangement scenarios. + +1 + +2 + +## 9.2.10 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC + +3 + +from Backhaul (LLS-C3)-Aggregated Link-BR1 to BR3 primary member link + +4 + +down. (Case-1: T-GM1 is the preferred GM) + +| Test ID | SYNC.RE.10 | Classification | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------------------| +| Test Title | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Aggregated Link-BR1 to BR3 primary member link down. (Case-1: T-GM1 is the preferred GM) | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| Pre-Req | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> </ul> | | | + +✓ Priority-2 on T-GM1=1 and T-GM2=2. + +### Test Topology: + +![Test Topology Diagram showing a network architecture with various components and connections.](7f179a39e169f8b9413d1d1b77cc61a5_img.jpg) + +Test Topology Diagram showing a network architecture with various components and connections. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. + +Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message. + +### Test Configuration + +1. Pre-condition-Test 9.2.9 Configuration. +2. Fail the Primary member link between BR1 and BR3 in the Aggregated Ethernet Bundle. + +### Procedure: + +#### Detailed Test procedure: + +1. Connect both T-GMs to GNSS Simulator. +2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile over Aggregated Link in backhaul and midhaul. +3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +#### Verifications for Clock Advertisements + +1. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +#### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\le 1100\text{ns}$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\le 1100\text{ns}$ (For Regular RU) + +#### Verifications for Maximum Relative Packet Time Error (NOTE1) + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data $(\max TE1, \min TE1)$ and $(\max TE2, \min TE2)$ for both O-RU UNI at least for a period of 1000sec. + +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + +- a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) +- b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) +- c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +| | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------|--------------------|--------------------|----------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +The above limits applicable for both Normal and Re-arrangement scenarios. + +## 9.2.11 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Normal State (Case-2: Both T-GMs are of equal preference) + +| Test ID | SYNC.RE.011 | Classification | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------------------| +| Test Title | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Normal State without any Fail-over conditions exist. (Case-2: Both T-GMs are of equal preference) | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>\text{Max} TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>\text{Max} TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>\text{Max} TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| Pre-Req | <ul style="list-style-type: none"> <li>✓ Both T-GM1 and T-GM2 are available to the network.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except GMCID.</li> <li>✓ Port-Identity of T-GM1 < Port-Identity of T-GM2.</li> </ul> | | | +| Test Topology: | <p>Image: Test Topology Diagram: A complex network diagram showing a ring topology. It includes O-DU1 and O-DU2 connected to HSR1, HSR2, HSR3, and HSR4. These are connected to BR1, BR2, BR3, and BR4. A Clock Tester is connected to CSRs. T-GM1 and T-GM2 are connected to the network. A GNSS Simulator and Frequency Reference are also shown. The diagram is divided into Ring1 Back-haul and Ring2 Mid-haul. Legend: TT: TimeTransmitter, ST: Stateful, P: Passive. BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router. 1PPS Ref = 10MHz Ref.</p> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | | | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>3. G.8275.1 Full Timing Support profile.</li> </ol> | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect both T-GMs to GNSS Simulator.</li> <li>2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile.</li> <li>3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI.</li> </ol> <p><b><u>Verifications for Clock Advertisements</u></b></p> <ol style="list-style-type: none"> <li>1. BR1 shall select clock from T-GM1 (T-GM1 is better by topology) based on Port-id of Sender of A and sender of B).</li> <li>2. BR2 shall select clock from T-GM1 (T-GM1 is better by topology) based on Port-id of Sender of A and sender of B).</li> <li>3. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned.</li> <li>4. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3.</li> </ol> <p><b><u>Verifications for Maximum Absolute Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP session is up and running between T-GM and CSR.</li> <li>2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. <ol style="list-style-type: none"> <li>a. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Enhanced RU)</li> <li>b. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error (NOTE1)</u></b></p> <ol style="list-style-type: none"> <li>1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data (<math>\max TE1, \min TE1</math>) and (<math>\max TE2, \min TE2</math>) for both O-RU UNI at least for a period of 1000sec.</li> <li>2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 60\text{ns}</math> (FR2) (For Enhanced RU)</li> <li>b. <math>\max TE_{RL} (1,2) \leq 190\text{ns}</math> (FR1) (For Enhanced RU)</li> <li>c. <math>\max TE_{RL} (1,2) \leq 100\text{ns}</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TE_{RL}(t)</math>, but to measure the maximum possible value it can take.</p> $\max TE_{RL} (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$ <p><b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP session is up and running between T-GM and CSR.</li> <li>2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. <ol style="list-style-type: none"> <li>a. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Enhanced RU)</li> </ol> </li> </ol> | + +| | | | | | | +|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------|----------------------------------------------------------------------------------------------------------------------|--------------------|----------------|--| +| <p>b. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100ns</math> (For Regular RU)</p> <p><b><u>Verifications for Maximum Relative 1PPS Time Error</u></b></p> <p>1. Verify that PTP and SyncE session is up and running.</p> <p>2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports.</p> <p>a. <math>\max TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</p> <p>b. <math>\max TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</p> <p>c. <math>\max TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</p> <p><b><u>Verifications for Time Wander</u></b></p> <p>1. Verify the Time Wander using Clock tester at the O-RU UNI.</p> <p>a. Frequency Limit is <math>\leq 32ppb</math> (For PRTC Class-A)</p> <p>b. MTIE mask as per the limit specified.</p> <p>NOTE1 (As per G.8271.1):</p> <p>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | | | | | | +| <b>Pass/Fail Criteria:</b> | | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | | +| | | (For Enhanced RU) | (For Regular RU) | | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | | +| | | $\leq 190ns$ (FR1) | | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | | +| | | $\leq 190ns$ (FR1) | | | | +| Frequency Limit (PRTC Class-A) | | $\leq 32ppb$ | $\leq 32ppb$ | | | +| The above limits applicable for both Normal and Re-arrangement scenarios. | | | | | | + +1 + +2 9.2.12 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC + +3 from Backhaul (LLS-C3)-T-GM1 to BR1 Link Down. (Case-2: Both T-GMs + +4 are of equal preference) + +| | | | | +|------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.12 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-T-GM1 to BR1 Link Down. (Case-2: Both T-GMs are of equal preference) | | | +| <b>Test Objective:</b> | <p>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</p> <p>2. Verify the clock advertisements on BRs, HSRs and CSRs.</p> | | | + +| | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>Verify the Time Wander at the O-RU UNI.</li> </ol> | +| Pre-Req | <ul style="list-style-type: none"> <li>Both T-GM1 and T-GM2 are available to the network.</li> <li>Clock parameters of both T-GM1 and T-GM2 are same except GMCID.</li> <li>Port-Identity of T-GM1 < Port-Identity of T-GM2.</li> <li>Test 9.2.11 MUST PASS.</li> </ul> | +| Test Topology: | <p>Image: Test Topology Diagram: A network diagram showing the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. The diagram includes components like CSR1, CSR2, HSR1, HSR2, HSR3, HSR4, BR1, BR2, BR3, BR4, BR5, BR6, T-GM1 (A), T-GM2 (B), and a Frequency Reference. It also shows Ring1 Back-haul and Ring2 Mid-haul. A legend indicates TT: TimeTransmitter, ST: Stateful, P: Passive. A note at the bottom right says 'BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router'.</p> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | +| Test Configuration | <ol style="list-style-type: none"> <li>As per Test 9.2.11.</li> <li>Fail the link between T-GM1 and BR1.</li> </ol> | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>Connect both T-GMs to GNSS Simulator.</li> <li>Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile.</li> <li>Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI.</li> </ol> <p><b>Verifications for Clock Advertisements</b></p> <ol style="list-style-type: none"> <li>BR1 shall select clock from T-GM2 (T-GM2 is better (or better by topology) based on Port-id of receiver of A and sender of A) on the shortest path with Step-removal=0.</li> <li>BR2 shall select clock from T-GM1 (T-GM1 is better by topology) based on Port-id of sender of A and sender of B).</li> <li>Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned.</li> </ol> | + +4. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +| | | | | | +|---------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------|-------------------|----------------| +| | To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | +| The above limits applicable for both Normal and Re-arrangement scenarios. | | | | | + +1 + +## 9.2.13 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Normal State (Case-3: T-GM1 is preferred through explicit configuration via Local-Priority on TNEs) + +| | | | | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.13 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Normal State without any Fail-over conditions exist. (Case-3: T-GM1 is preferred through explicit configuration via Local-Priority on TNEs) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <ul style="list-style-type: none"> <li>✓ Both T-GM1 and T-GM2 are available to the network.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except GMCID.</li> <li>✓ Local Priority Configuration on BR1 and BR2 for T-GM1 is 1 and that for T-GM2 is 2.</li> </ul> | | | + +## Test Topology: + +![Test Topology Diagram showing a network architecture with various components and connections.](30d4c28df95d6b1e4152bc5aa3378335_img.jpg) + +The diagram illustrates a test topology for O-RAN. It features a central 'Ring2 Mid-haul' and a 'Ring1 Back-haul'. Key components include: + +- CSRs (Cell Site Routers):** CSR1 and CSR2 are connected to the O-RU UNI and the Clock Tester. +- HSRs (Hub Site Routers):** HSR1, HSR2, HSR3, and HSR4 are part of the Ring2 Mid-haul. +- BRs (Backhaul Routers):** BR1, BR2, BR3, and BR4 are part of the Ring1 Back-haul. +- O-DUs (Open Distributed Units):** O-DU1 and O-DU2 are connected to the HSRs. +- T-Tx (Time Transmitters):** T-Tx1 and T-Tx2 are connected to the CSRs. +- T-Rx (Time Receivers):** T-Rx1 and T-Rx2 are connected to the CSRs. +- Legend:** + - TT: Time Transmitter + - ST: Stateful + - P: Passive + - LP: Local Priority + +Connections are shown with solid lines (PTP), dashed lines (SYNCE), and dotted lines (Standby). The diagram also shows a 'Clock Tester' connected to the CSRs and a 'GNSS Simulator' connected to the T-Tx and T-Rx. + +Test Topology Diagram showing a network architecture with various components and connections. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. + +Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message. + +## Test Configuration + +1. Clock Tester at O-RU UNI receives timing input on its measurement port. +2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +3. G.8275.1 Full Timing Support profile. + +## Procedure: + +### Detailed Test procedure: + +1. Connect both T-GMs to GNSS Simulator. +2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile. +3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +### Verifications for Clock Advertisements + +1. BR1 and BR2 shall select clock from T-GM1. +2. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +3. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +### Verifications for Maximum Relative Packet Time Error (NOTE1) + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. + +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + +- a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) +- b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) +- c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +| | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------|--------------------|--------------------|----------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +The above limits applicable for both Normal and Re-arrangement scenarios. + +## 9.2.14 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-T-GM1 to BR1 Link Down. (Case-3: T-GM1 is preferred through explicit configuration via Local-Priority on TNEs) + +| Test ID | SYNC.RE.14 | Classification | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------------------| +| Test Title | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-T-GM1 to BR1 Link Down. (Case-3: T-GM1 is preferred through explicit configuration via Local-Priority on TNEs) | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| Pre-Req | <ul style="list-style-type: none"> <li>✓ Both T-GM1 and T-GM2 are available to the network.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except GMCID.</li> <li>✓ Local Priority Configuration on BR1 and BR2 for T-GM1 is 1 and that for T-GM2 is 2.</li> <li>✓ Test 9.2.13 MUST PASS.</li> </ul> | | | +| Test Topology: | <p>Image: Test Topology Diagram for Case-3: T-GM1 is preferred through explicit configuration via Local-Priority on TNEs. The diagram shows a ring topology with O-DU1 and O-DU2 connected to HSRs (HSR1, HSR2, HSR3, HSR4) and BRs (BR1, BR2, BR3, BR4). T-GM1 (A) and T-GM2 (B) are connected to the network. A link between T-GM1 and BR1 is shown as down. The diagram includes a legend for TT (Time Transmitter), ST (Stateful), P (Passive), LP (Local Priority), and a legend for BR (Backhaul Router), HSR (Hub Site Router), and CSR (Cell Site Router).</p> | | | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>As per Test 9.2.13.</li> <li>Fail the link between T-GM1 and BR1.</li> </ol> | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>Connect both T-GMs to GNSS Simulator.</li> <li>Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile.</li> <li>Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI.</li> </ol> <p><b><u>Verifications for Clock Advertisements</u></b></p> <ol style="list-style-type: none"> <li>BR1 shall select clock from T-GM2.</li> <li>BR2 shall select clock from T-GM1.</li> <li>Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned.</li> <li>Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3.</li> </ol> <p><b><u>Verifications for Maximum Absolute Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify that PTP session is up and running between T-GM and CSR.</li> <li>Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. <ol style="list-style-type: none"> <li><math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Enhanced RU)</li> <li><math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error (NOTE1)</u></b></p> <ol style="list-style-type: none"> <li>Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data (<math>\max TE1, \min TE1</math>) and (<math>\max TE2, \min TE2</math>) for both O-RU UNI at least for a period of 1000sec.</li> <li>Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li><math>\max TE_{RL} (1,2) \leq 60\text{ns}</math> (FR2) (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 190\text{ns}</math> (FR1) (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 100\text{ns}</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TE_{RL}(t)</math>, but to measure the maximum possible value it can take.</p> $\max TE_{RL} (1,2)\text{ the greatest of } \begin{cases} (\max TE_L(1) - \min TE_L(2)) \\ (\max TE_L(2) - \min TE_L(1)) \end{cases}$ <p><b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify that PTP session is up and running between T-GM and CSR.</li> </ol> | + +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +| | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------|--------------------|--------------------|----------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| | | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | +| | The above limits applicable for both Normal and Re-arrangement scenarios. | | | | + +## 9.2.15 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul (LLS-C3)-Normal State (Passive Port Monitoring) + +| | | | | +|----------------|------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.15 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +|----------------|------------|-----------------------|------------------------------------------------------------------------------------| + +| | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Backhaul-Normal State without any Fail-over conditions exist. (Passive Port Monitoring) | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | +| <b>Pre-Req</b> | <ul style="list-style-type: none"> <li>✓ Both T-GM1 and T-GM2 are available to the network.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except GMCID.</li> <li>✓ Port-Identity of T-GM1 < Port-Identity of T-GM2.</li> </ul> | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A network diagram showing a ring topology with two rings (Ring1 Back-haul and Ring2 Mid-haul). Components include CSRs (Cell Site Routers), HSRs (Hub Site Routers), BRs (Backhaul Routers), O-DUs (Open Distributed Units), and T-GMs (Timing and Synchronization Modules). A Clock Tester is connected to CSRs at the O-RU UNI. A GNSS Simulator provides 1PPS and 10MHz references to the Clock Tester. The diagram shows various ports (ST, TT, PTP, SYNC, Standby) and their connections. A legend at the bottom right defines the components: BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router. A legend at the bottom left defines the port states: TT: TimeTransmitter, ST: Stateful, P: Passive." data-bbox="422 817 1428 1332" src="9082fdc6e1af8f33c92b9f0904427246_img.jpg"/> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Clock Tester at O-RU UNI receives timing input on its measurement port.</li> <li>2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>3. G.8275.1 Full Timing Support profile.</li> <li>4. Introduce Asymmetry of 1000ns between BR3 and BR5.</li> </ol> | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect both T-GMs to GNSS Simulator.</li> <li>2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile.</li> <li>3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI.</li> </ol> <p><b>Verifications for Clock Advertisements</b></p> | + +1. BR1 shall select clock from T-GM1 (T-GM1 is better by topology) based on Port-id of Sender of A and sender of B). +2. BR2 shall select clock from T-GM1 (T-GM1 is better by topology) based on Port-id of Sender of A and sender of B). +3. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +4. After step-4 in Test Configuration, Verify Performance Measurement during steady state. (1PPS and Packet Time Error should show an Error of +/-500ns) +5. BR6 should raise an alarm based on the configured Alarm Threshold. +6. BR6 should estimate the path asymmetry between the two paths. +7. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}| (1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}| (1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}| (1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}| (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + +| | | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------|-------------------|----------------| +| | <ol style="list-style-type: none"> <li><math>\max TE_{RL} (1,2) \leq 60ns (FR2)</math> (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 190ns (FR1)</math> (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 100ns (FR1)</math> (For Regular RU)</li> </ol> <p><b>Verifications for Time Wander</b></p> <ol style="list-style-type: none"> <li>Verify the Time Wander using Clock tester at the O-RU UNI. <ol style="list-style-type: none"> <li>Frequency Limit is <math>\leq 32ppb</math> (For PRTC Class-A)</li> <li>MTIE mask as per the limit specified.</li> </ol> </li> </ol> <p>NOTE1 (As per G.8271.1):<br/>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$<br>$\leq 190ns(FR1)$ | $\leq 100ns(FR1)$ | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$<br>$\leq 190ns(FR1)$ | $\leq 100ns(FR1)$ | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | +| | The above limits for $\max TE_L $ doesn't include the error due to Manual Asymmetry. | | | | + +## 9.2.16 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul (LLS-C3)-Normal State (Case-1: T-GM1 is the preferred GM) + +| | | | | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.16 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul-Normal State without any Fail-over conditions exist. (Case-1: T-GM1 is the preferred GM) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | ✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM in the Midhaul. | | | + +- ✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID. +- ✓ Priority-2 on T-GM1=1 and T-GM2=2. + +### Test Topology: + +![Test Topology Diagram showing the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The diagram illustrates a network topology with various components including O-DU1, O-DU2, CSR1, CSR2, HSR1, HSR2, HSR3, HSR4, T-GM1, T-GM2, BR1, BR2, BR3, BR4, BR5, BR6, and a Clock Tester. The diagram shows connections for PTP, SYNC, and Standby signals, and includes a legend for BR (Backhaul Router), HSR (Hub Site Router), and CSR (Cell Site Router).](305ce8e9bc20b9d86576301d96af015a_img.jpg) + +The diagram illustrates a test topology for clock synchronization. It shows a central network area containing several components: O-DU1 and O-DU2 (Top and Bottom Distributed Units), CSR1 and CSR2 (Cell Site Routers), HSR1, HSR2, HSR3, and HSR4 (Hub Site Routers), T-GM1 and T-GM2 (Time-to-Time Gateways), and a set of Backhaul Routers (BR1 through BR6). A Clock Tester is connected to CSR1 and CSR2. A GNSS Simulator provides a 1PPS Ref + 10MHz Ref signal to the Clock Tester. The diagram also shows connections for PTP (Precision Time Protocol), SYNC (Synchronization), and Standby signals. A legend indicates that BR stands for Backhaul Router, HSR for Hub Site Router, and CSR for Cell Site Router. + +Test Topology Diagram showing the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The diagram illustrates a network topology with various components including O-DU1, O-DU2, CSR1, CSR2, HSR1, HSR2, HSR3, HSR4, T-GM1, T-GM2, BR1, BR2, BR3, BR4, BR5, BR6, and a Clock Tester. The diagram shows connections for PTP, SYNC, and Standby signals, and includes a legend for BR (Backhaul Router), HSR (Hub Site Router), and CSR (Cell Site Router). + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. + +Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message. + +### Test Configuration + +1. Clock Tester at O-RU UNI receives timing input on its measurement port. +2. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +3. G.8275.1 Full Timing Support profile. + +### Procedure: + +#### Detailed Test procedure: + +1. Connect both T-GMs to GNSS Simulator. +2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile. +3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +#### Verifications for Clock Advertisements + +1. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +#### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + +- b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}| (1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}| (1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}| (1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}| (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}| (1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}| (1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}| (1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### **Pass/Fail Criteria:** + +Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. + +#### **Test Output** + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|-------------------|--------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | + +| | | | | | +|---------------------------------------------------------------------------|--------------------------------|---------------------------------------|-------------------|--| +| | | $\leq 190ns(FR1)$ | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$<br>$\leq 190ns(FR1)$ | $\leq 100ns(FR1)$ | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | +| The above limits applicable for both Normal and Re-arrangement scenarios. | | | | | + +### 9.2.17 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul (LLS-C3)-T-GM1 to HSR1 Link Down. (Case-1: T-GM1 is the preferred GM) + +| | | | | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.17 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul-T-GM to HSR1 Link Down. (Case-1: T-GM1 is the preferred GM) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM in the Midhaul.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> <li>✓ Priority-2 on T-GM1=1 and T-GM2=2.</li> </ul> | | | + +## Test Topology: + +![Test Topology Diagram showing the placement of clock tester and GNSS simulator. The diagram illustrates a network architecture with various components: O-DU1, O-DU2, CSR1, CSR2, HSR1, HSR2, HSR3, HSR4, T-GM1, T-GM2, BR1, BR2, BR3, BR4, BR5, BR6, and a Clock Tester. The Clock Tester is connected to CSR1 and CSR2 via O-RU UNI. The GNSS Simulator is connected to T-GM1 and T-GM2. The network is divided into Ring1 Back-haul and Ring2 Mid-haul. A Frequency Reference is also shown. A legend indicates: TT: TimeTransmitter, ST: Stateful, TR: TimeReceiver, BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router. A note at the top right says '1PPS Ref + 10MHz Ref'.](ba727b73ec7c2451a5cb8f9e82f055f8_img.jpg) + +Test Topology Diagram showing the placement of clock tester and GNSS simulator. The diagram illustrates a network architecture with various components: O-DU1, O-DU2, CSR1, CSR2, HSR1, HSR2, HSR3, HSR4, T-GM1, T-GM2, BR1, BR2, BR3, BR4, BR5, BR6, and a Clock Tester. The Clock Tester is connected to CSR1 and CSR2 via O-RU UNI. The GNSS Simulator is connected to T-GM1 and T-GM2. The network is divided into Ring1 Back-haul and Ring2 Mid-haul. A Frequency Reference is also shown. A legend indicates: TT: TimeTransmitter, ST: Stateful, TR: TimeReceiver, BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router. A note at the top right says '1PPS Ref + 10MHz Ref'. + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. + +Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message. + +## Test Configuration + +1. Pre-condition-Test 9.2.11 Configuration. +2. Fail the link between T-GM1 and HSR1. + +## Procedure: + +### Detailed Test procedure: + +1. Connect both T-GMs to GNSS Simulator. +2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile. +3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +### Verifications for Clock Advertisements + +1. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +### Verifications for Maximum Relative Packet Time Error (NOTE1) + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1$ , $\min TE1$ ) and ( $\max TE2$ , $\min TE2$ ) for both O-RU UNI at least for a period of 1000sec. + +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + +- a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) +- b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) +- c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +| | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------|--------------------|--------------------|----------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +The above limits applicable for both Normal and Re-arrangement scenarios. + +## 9.2.18 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul (LLS-C3)-T-GM1 Fail-over. (Case-1: T-GM1 is the preferred GM) + +| Test ID | SYNC.RE.18 | Classification | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------------------| +| Test Title | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul-T-GM1 Fail-over. (Case-1: T-GM1 is the preferred GM) | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| Pre-Req | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM in the Midhaul.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> <li>✓ Priority-2 on T-GM1=1 and T-GM2=2.</li> </ul> | | | +| Test Topology: | <p>Image: Test Topology Diagram: A complex network diagram showing the test setup. It includes O-DU1 and O-DU2 connected to CSRs (Cell Site Routers) and HSRs (Hub Site Routers). The CSRs are connected to a Clock Tester. The HSRs are connected to T-GM1 and T-GM2 (Time-to-Geometry Modules) which are connected to a GNSS Simulator. The HSRs are also connected to BRs (Backhaul Routers) in a ring topology. The diagram shows various connections for PTP, SYNC, and Standby signals. A legend at the bottom right defines the components: BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router. A legend at the bottom left defines the signal types: TT: TimeTransmitter, ST: Stateful, TR: TimeReceiver. A legend at the bottom center defines the signal types: PTP, SYNC, Standby.</p> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> | | | + +| | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. Pre-condition-Test 9.2.11 Configuration.</li> <li>2. Fail the links between T-GM1 to HSR1 and HSR2.</li> </ol> | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect both T-GMs to GNSS Simulator.</li> <li>2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile.</li> <li>3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI.</li> </ol> <p><b><u>Verifications for Clock Advertisements</u></b></p> <ol style="list-style-type: none"> <li>1. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned.</li> <li>2. Verify the clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3.</li> </ol> <p><b><u>Verifications for Maximum Absolute Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP session is up and running between T-GM and CSR.</li> <li>2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. <ol style="list-style-type: none"> <li>a. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Enhanced RU)</li> <li>b. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error (NOTE1)</u></b></p> <ol style="list-style-type: none"> <li>3. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data <math>(\max TE1, \min TE1)</math> and <math>(\max TE2, \min TE2)</math> for both O-RU UNI at least for a period of 1000sec.</li> <li>4. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 60\text{ns}</math> (FR2) (For Enhanced RU)</li> <li>b. <math>\max TE_{RL} (1,2) \leq 190\text{ns}</math> (FR1) (For Enhanced RU)</li> <li>c. <math>\max TE_{RL} (1,2) \leq 100\text{ns}</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p>As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, <math>TE_{RL}(t)</math>, but to measure the maximum possible value it can take.</p> $\max TE_{RL} (1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$ <p><b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP session is up and running between T-GM and CSR.</li> <li>2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. <ol style="list-style-type: none"> <li>a. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Enhanced RU)</li> <li>b. <math>\max TE_L </math> measured on Clock Tester at the O-RU UNI <math>\leq 1100\text{ns}</math> (For Regular RU)</li> </ol> </li> </ol> | + +### Verifications for Maximum Relative 1PPS Time Error + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns (FR2)$ (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns (FR1)$ (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns (FR1)$ (For Regular RU) + +### Verifications for Time Wander + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +### Pass/Fail Criteria: + +Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. + +### Test Output + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|-------------------|-------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +The above limits applicable for both Normal and Re-arrangement scenarios. + +## 9.2.19 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul (LLS-C3)-Link Failure in Fronthaul. (Case-1: T-GM1 is the preferred GM) + +| Test ID | SYNC.RE.19 | Classification | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------------------| +| Test Title | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul-Link Failure in Fronthaul. (Case-1: T-GM1 is the preferred GM) | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> </ol> | | | + +| | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <ol style="list-style-type: none"> <li>Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>Verify the Time Wander at the O-RU UNI.</li> </ol> | +| Pre-Req | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM in the Mid-haul.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> <li>✓ Priority-2 on T-GM1=1 and T-GM2=2.</li> </ul> | +| Test Topology: | <p>1PPS Ref + 10MHz Ref</p> <p>Image: Test Topology Diagram: A network diagram showing the placement of a clock tester at the measurement plane. The diagram includes O-RU UNI (O-DU1, O-DU2), T-BC/eEECs, HSRs (HSR1, HSR2, HSR3, HSR4), T-GMs (T-GM1, T-GM2), GNSS Simulator, and Backhaul Routers (BR1, BR2, BR3, BR4, BR5, BR6). The clock tester is connected to CSR1 and CSR2. The diagram also shows Ring1 Back-haul and Ring2 Mid-haul. A legend indicates: BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router, TT: TimeTransmitter, ST: Stateful, TR: TimeReceiver. A legend also shows: PTP (red), SYNC (green), Standby (blue).</p> <p>The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR.</p> <p>Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message.</p> | +| Test Configuration | <ol style="list-style-type: none"> <li>Pre-condition-Test 9.2.11 Configuration.</li> <li>Fail the link between HSR3 and CSR1.</li> </ol> | +| Procedure: | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>Connect both T-GMs to GNSS Simulator.</li> <li>Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile.</li> <li>Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI.</li> </ol> <p><b>Verifications for Clock Advertisements</b></p> <ol style="list-style-type: none"> <li>Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned.</li> <li>Verify the clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3.</li> </ol> <p><b>Verifications for Maximum Absolute Packet Time Error</b></p> <ol style="list-style-type: none"> <li>Verify that PTP session is up and running between T-GM and CSR.</li> </ol> | + +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error (NOTE1)** + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $\max TE1, \min TE1$ ) and ( $\max TE2, \min TE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify the 1PPS time error measurements using Clock Tester at the O-RU UNI. + - a. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Time Wander** + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### **Pass/Fail Criteria:** + +Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. + +| Test Output | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|---------------------------------------------------------------------------|--------------------------------------|-------------------|-------------------|----------------| +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | +| The above limits applicable for both Normal and Re-arrangement scenarios. | | | | | + +## 9.2.20 Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul (LLS-C3)-Asymmetry Test. (Case-1: T-GM1 is the preferred GM) + +| | | | | +|------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.RE.20 | <b>Classification</b> | Resiliency, Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Timing Resiliency in Ring Topology-O-DU connected to HSR and SYNC from Midhaul-Asymmetry Test. (Case-1: T-GM1 is the preferred GM) | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on BRs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between two O-RU UNI ports.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Time Wander at the O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <ul style="list-style-type: none"> <li>✓ T-GM1 is the Primary GM and T-GM2 is the Secondary GM.</li> <li>✓ Clock parameters of both T-GM1 and T-GM2 are same except Priority-2 & GMCID.</li> <li>✓ Priority-2 on T-GM1=1 and T-GM2=2.</li> </ul> | | | + +## Test Topology: + +![Test Topology Diagram showing the placement of clock tester, GNSS simulator, and various network elements (O-DU, HSR, T-GM, BR, CSR) connected via Ring1 Back-haul and Ring2 Mid-haul. The diagram includes a legend for port types (TT, ST, TR) and connection types (PTP, SYNC, Standby).](04687923551fa2e922c3fd885713b072_img.jpg) + +The diagram illustrates a test topology for clock synchronization. It features a central GNSS Simulator connected to two Time-Group Managers (T-GM1 and T-GM2). These T-GMs are connected to a Ring2 Mid-haul, which in turn connects to a Ring1 Back-haul. The Ring1 Back-haul consists of Backhaul Routers (BR1-BR6). The Ring2 Mid-haul connects to Hub Site Routers (HSR1-HSR4). These HSRs are connected to Cell Site Routers (CSR1, CSR2) and O-DUs (O-DU1, O-DU2). A Clock Tester is connected to the CSRs. The diagram also shows a Frequency Reference and a 1PPS Ref + 10MHz Ref source. A legend indicates: TT: TimeTransmitter, ST: Stateful, TR: TimeReceiver; BR: Backhaul Router, HSR: Hub Site Router, CSR: Cell Site Router; and connection types: PTP (solid orange), SYNC (dashed orange), and Standby (dashed green). + +Test Topology Diagram showing the placement of clock tester, GNSS simulator, and various network elements (O-DU, HSR, T-GM, BR, CSR) connected via Ring1 Back-haul and Ring2 Mid-haul. The diagram includes a legend for port types (TT, ST, TR) and connection types (PTP, SYNC, Standby). + +The test topology above illustrates the placement of clock tester at the measurement plane with 1PPS and 10MHz reference from GNSS simulator connected to clock tester. The tester measurement ports at O-RU UNI connected to CSR. + +Stateful (ST) refers to the port configuration of neither explicit timeTransmitter nor explicit timeReceiver. When configured, it refers to the dynamic state of the port based on the received Announce message. + +## Test Configuration + +1. As per Test 9.2.11. +2. Introduce Asymmetry of +1000ns at the O/p of T-GM1 and No Asymmetry at the O/p of T-GM2. +3. Configure Asymmetry Compensation of +1000ns on HSR1 and HSR2. + +## Procedure: + +### Detailed Test procedure: + +1. Connect both T-GMs to GNSS Simulator. +2. Configure T-GMs, BRs, HSRs and CSRs with G.8275.1 profile. +3. Connect Clock Tester measurement ports to CSRs TimeTransmitter ports to monitor PTP at the O-RU UNI. + +### Verifications for Clock Advertisements + +1. Verify the clock lock state on BRs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the steady-state clock advertisements on BRs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +### After Step-2 of Test Configurations + +### Verifications for Maximum Absolute Packet Time Error and 1PPS Time Error + +1. Verify Performance Measurement during steady state. (1PPS and Packet Time Error should show an additional Error of +/-500ns due to Asymmetry) + +### Verifications for Maximum Relative Packet Time Error (NOTE1) + +1. Perform time error measurements on Clock Tester at O-RU1 and O-RU2 plane independently. Collect the data ( $maxTE1$ , $minTE1$ ) and ( $maxTE2$ , $minTE2$ ) for both O-RU UNI at least for a period of 1000sec. +2. Estimate the Maximum Relative Time Error measurements between the O-RU UNI ports. + +- a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) +- b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) +- c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +As per ITU-T G.8271.1 Appendix-V1, the requirement is not to measure the continuous relative time error, $TE_{RL}(t)$ , but to measure the maximum possible value it can take. + +$$\max|TE_{RL}|(1,2) \text{ the greatest of } \begin{cases} \max TE_L(1) - \min TE_L(2) \\ \max TE_L(2) - \min TE_L(1) \end{cases}$$ + +#### Verifications for Maximum Relative 1PPS Time Error + +1. Verify that PTP and SyncE session is up and running. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### Verifications for Time Wander + +1. Verify the Time Wander using Clock tester at the O-RU UNI. + - a. Frequency Limit is $\leq 32ppb$ (For PRTC Class-A) + - b. MTIE mask as per the limit specified. + +NOTE1 (As per G.8271.1): + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### After Step-3 of Test Configurations + +#### Verifications for Maximum Absolute Packet Time Error and 1PPS Time Error + +1. Verify Performance Measurement during steady state. (1PPS and Packet Time Error shouldn't show any additional Error of +/-500ns due to Asymmetry) + +#### Verifications for Maximum Relative Packet Time Error and 1PPS Time Error + +1. Verify the Maximum Relative 1PPS Time Error measurements between the O-RU UNI ports. The results should be as per Test 9.2.11. + +#### **Pass/Fail Criteria:** + +Test shall pass if the Maximum Absolute TE, Relative TE and Time Wander Limit result is within the specified limits. + +#### **Test Output** + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|--------------------|--------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| Frequency Limit (PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +The above limits for $\max|TE_L|$ doesn't include the error due to Manual Asymmetry. + +## 9.3 Timing Solution Additional use cases in LLS-C3 and LLS-C4 config + +This chapter specifies a few additional use cases in LLS-C3 and LLS-C4 config models. Also LLS-C3 and LLS-C4 mixed configuration with and without GNSS assist and redundant T-GMs for co-located DUs and RUs are discussed. Each of these use cases are specified with performance limits and Pass/Fail verdict in normal and fail-over scenarios of GNSS and T-GM. + +These use cases in high level are already mentioned in the O-RAN WG9 Synchronization Architecture and Solution Specification. Depending on the specific O-RAN deployment being considered, not all of them might be relevant. When testing the S-Plane, the System Integrator shall identify which of the test cases are relevant depending on the specific deployment scenarios addressed. + +Following high level use cases have been covered in this chapter and each of these use cases, clock performance limits are discussed for normal and failover scenarios. + +### 1. LLS-C3 and LLS-C4 Configuration and Use case. + +- a. LLS-C4 with PTP frequency backup from T-GM +- b. LLS-C4 with PTP time backup from T-GM +- c. LLS-C4 and LLS-C3 mixed configurations for co-located DUs and RUs +- d. LLS-C4 and LLS-C3 mixed configurations for co-located DUs and RUs (GNSS Failure at O-RU site) +- e. LLS-C4 and LLS-C3 mixed configurations with backup from T-GM for co-located DUs and RUs +- f. LLS-C4 and LLS-C3 mixed configurations with backup from T-GM for co-located DUs and RUs (GNSS Failure at O-RU site) +- g. LLS-C4 and LLS-C3 mixed configurations with backup from redundant T-GM for co-located DUs and RUs (GNSS Failure at O-RU site and T-GM-A Failure) +- h. LLS-C3 configurations with GNSS assisted CSR for co-located DUs and RUs +- i. LLS-C3 configurations with (GNSS+PRTC) assisted CSR for co-located DUs and RUs +- j. LLS-C3 configurations with GNSS assisted CSR with backup from redundant T-GM for co-located DUs and RUs +- k. LLS-C3 configurations with GNSS assisted CSR with backup from redundant T-GM for co-located DUs and RUs (GNSS Failure at CSR site) +- l. LLS-C3 configurations with GNSS assisted CSR with backup from redundant T-GM for co-located DUs and RUs (GNSS Failure at CSR site and T-GM-A Failure) + +O-RU UNI specified in the topology is for the network measurement. Two measurement planes have been specified in the document to cover all measurements. One at O-RU UNI for measuring X-haul network limits (Packet + 1PPS) and other at 1PPS measurement plane of O-RU to measure the 1PPS performance limits of O-RU in LLS-C4 configuration. Operator to position the Tester on these measurement planes for conducting the respective test. + +The performance limits of O-RU in LLS-C4 when it is locked to local GNSS receiver has been specified in O-RAN.WG4.CUS documents. As per this specifications, the budget shall be based on ITU-T G.8272 (PRTC class A, with max $|TE|=100\text{ns}$ , or PRTC class B, with max $|TE|=40\text{ns}$ on each GNSS receiver and max $|TE|=30\text{ns}$ on O-RU. Max $|TE|$ O-RU includes the O-RU clock recovery error from Local Time Source and any O-RU internal error. The LLS-C4 test cases in this section assumes the O-RU T-TSC Error of 10ns and O-RU internal Error of 20ns to arrive at the possible limits. + +The test cases apply to both lab and field deployment cases. The test topologies in this test specification specify only few Transport Node Elements (TNEs) for illustration. However, for lab cases, the type and number of inserted Transport Node Elements (TNE) will be determined by operators (or any other applicable end customer) subject to the O-RU UNI limits. Some of the tests are performed at Xhaul UNI interfaces and some are at the O-RU 1PPS interfaces. The Xhaul UNI interfaces include O-RU Fronthaul UNI, O-DU Fronthaul or Midhaul UNI. + +1PPS test at O-RU UNI is typically used for debugging and monitoring the packet layer performance of the nearest TNE in the fronthaul. The intention of such test is that if the TNE vendor implemented the 1PPS interface, the 1PPS error measured on such interface at the O-RU UNI should be a reflection of the output time error of TNE. Operator shall pay attention to an unacceptably large deviation of 1PPS error, beyond the limits specified, which may indicate an incorrect behaviour of TNEs. + +The Test Topologies in all the test cases uses GNSS simulator to generate the GNSS signal to the network PRTC/T-GM. This high-quality reference from the simulator is used as the external reference for clock testers as well. The resultant accuracy of this method is a few nanoseconds. However, one can also use a GNSS signal feeding both the initial PRTC/T-GM in the network and the reference clock generating a 1pps/10MHz used to synchronize the clock testers for the measurements. Operator can make an allowance in this case, for all of the measurements for the accuracy of the reference. The magnitude of this allowance will depend on the specific GNSS reference in use. + +For relative time error measurements at UNI (e.g., O-RU Fronthaul UNI) this document uses the metric $\max|TE_{RL}|(1,2)$ as defined in [88], Appendix XI. Please note this metric represents an estimation and the worst-case scenario. Tests that meet (are below) the limits are seen as PASS. Tests not meeting this metric may still be acceptable. The decision is for operators to make. However, if the measurement equipment support relative time error measurement, operator can use such equipment. Refer ITU-T G.8271.1 Appendix XI for more details. + +For Frequency Limit at UNI (e.g., O-RU Fronthaul UNI) this document uses the metric defined as per WG4 section H.2 based on PRTC class for LLS-C3 configuration. Applicable MTIE limit shall apply for Frequency as per WG4 specification. + +### 9.3.1 Network Time Synchronization-LLS-C4 with PTP frequency backup from T-GM + +| <b>Test ID</b> | SYNC.TE.3 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +|------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at the 1PPS measurement plane of O-RU. LLS-C4 with PTP frequency backup from T-GM. | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at 1PPS Measurement Plane of O-RUs.</li> <li>2. Verify the Maximum Relative 1PPS Time Error (<math>\max TE_{RL} </math>) at 1PPS Measurement Plane between O-RUs.</li> </ol> | | | +| <b>Pre-Req</b> | T-GM/PRTC connected to GNSS simulator and ensure T-GM is locked.<br>Tester 1PPS measurement port connected to O-RU 1PPS out is the measurement plane. | | | + +## Test Topology: + +![Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, CSR, O-DUs, O-RUs, and Clock Testers. The diagram illustrates the placement of clock testers at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester. Key components include: GNSS Simulator (providing RF Signal and 1PPS Ref+10MHz Ref), T-GM (Time and Frequency Management), CSR (Clock Synchronization Reference), O-DUs (O-DU1, O-DU2) and O-RUs (O-RU1, O-RU2). Clock Testers are connected to O-RUs and O-DUs. Performance metrics are listed: PRTC-A, |TE| ≤ 100ns; PRTC-B, |TE| ≤ 40ns; ePRTC, |TE| ≤ 30ns; |TE| ≤ 1100ns; 1PPS TE ≤ 110ns; 1PPS TE ≤ 160ns. Max TAE = 260ns; Max |1PPS TE_L| ≤ 110ns at 1PPS Meas. Plane; Max |1PPS TE_H| ≤ 220ns at 1PPS Meas. Plane.](48ce318f03f17fe720ef0d72f05be128_img.jpg) + +Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, CSR, O-DUs, O-RUs, and Clock Testers. The diagram illustrates the placement of clock testers at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester. Key components include: GNSS Simulator (providing RF Signal and 1PPS Ref+10MHz Ref), T-GM (Time and Frequency Management), CSR (Clock Synchronization Reference), O-DUs (O-DU1, O-DU2) and O-RUs (O-RU1, O-RU2). Clock Testers are connected to O-RUs and O-DUs. Performance metrics are listed: PRTC-A, |TE| ≤ 100ns; PRTC-B, |TE| ≤ 40ns; ePRTC, |TE| ≤ 30ns; |TE| ≤ 1100ns; 1PPS TE ≤ 110ns; 1PPS TE ≤ 160ns. Max TAE = 260ns; Max |1PPS TE\_L| ≤ 110ns at 1PPS Meas. Plane; Max |1PPS TE\_H| ≤ 220ns at 1PPS Meas. Plane. + +The test topology above illustrates the placement of clock tester at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester. + +## Test Configuration + +1. T-GM, CSR, O-RUs and O-DUs are connected and configured as shown in the Test Topology. +2. Clock Tester at O-RU 1PPS measurement plane receives timing input on its measurement port. +3. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +4. GNSS (PRTC-A) is connected to O-RU and O-DUs. +5. G.8275.1 Full Timing Support profile. + +## Procedure: + +### Detailed Test procedure: + +1. GNSS (PRTC-A) is connected directly to O-RUs and O-DUs. +2. O-RU and O-DU use the GNSS (PRTC-A) as the primary clock source and use Frequency as backup from the T-GM at the central location. +3. Connect T-GM to GNSS Simulator and ensure that T-GM is locked. +4. Configure O-RU and O-DU as T-TSC and CSR as T-BC. +5. Enable G.8275.1 profile on all transport TNEs (CSR). +6. Connect Clock tester measurement ports to O-RU 1PPS monitor port to measure the 1PPS at measurement plane. +7. Establish PTP and Sync-E session to the fronthaul network. + +### Verifications for Maximum Absolute 1PPS Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify that both O-RU and O-DU locked to GNSS (PRTC-A) as the primary clock source. +3. Verify the 1PPS time error measurements on Clock Tester at the 1PPS measurement plane. + - a. $\text{Max}|1\text{PPS } TE_L|$ measured on Clock Tester at the 1PPS measurement plane of O-RU $\le 110\text{ns}$ + +### Verifications for Maximum Relative 1PPS Time Error + +1. Verify that PTP and Sync-E session is up and running. + +| | | | | | +|--------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|----------------|--| +| | <ol style="list-style-type: none"> <li>2. Verify that both O-RU and O-DU locked to GNSS (PRTC-A) as the primary clock source.</li> <li>3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs at 1PPS measurement plane. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 220ns</math></li> </ol> </li> </ol> <p>NOTE1:<br/>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | | | | +| | <b>Pass/Fail Criteria:</b> Test shall pass if the Maximum absolute TE, Maximum Relative TE, and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit | Expected Value | Observed Value | | +| | 1PPS $\max TE_L $ at 1PPS measurement plane | $\leq 110ns$ | | | +| | 1PPS $\max TE_{RL} $ at 1PPS measurement plane | $\leq 220ns$ | | | + +## 9.3.2 Network Time Synchronization-LLS-C4 with PTP Time backup from T-GM + +| | | | | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.4 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at 1PPS measurement plane of O-RU. LLS-C4 with PTP Time backup from T-GM. | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at 1PPS Measurement Plane of O-RUs.</li> <li>2. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at 1PPS Measurement Plane between O-RUs.</li> </ol> | | | +| <b>Pre-Req</b> | T-GM/PRTC connected to GNSS simulator and ensure T-GM is locked.<br>Tester 1PPS measurement port connected to O-RU 1PPS out is the measurement plane. | | | + +## Test Topology: + +![Test Topology Diagram showing the placement of clock tester at the 1PPS measurement plane. The diagram illustrates a central T-GM (Timing and Synchronization Manager) connected to a GNSS Simulator and a Frequency Reference. The T-GM is connected to O-DUs (O-DU1, O-DU2) and O-RUs (O-RU1, O-RU2) via O-DU UNI and O-RU UNI interfaces. The O-DUs and O-RUs are connected to Clock Testers. The Clock Testers are connected to the 1PPS measurement plane. The diagram also shows GNSS (PRTC-A) connections to O-RUs and O-DUs. Timing constraints are specified: |TE| ≤ 110ns for O-DU and O-RU connections, and 1PPS TE ≤ 110ns for the Clock Tester. Performance metrics are listed: Max TAE = 260ns, Max 1PPS TE ≤ 110ns at 1PPS Meas. Plane, and Max 1PPS TE ≤ 220ns at 1PPS Meas. Plane.](35ee0e15a1f76635bd440b1dc1bea31d_img.jpg) + +Test Topology Diagram showing the placement of clock tester at the 1PPS measurement plane. The diagram illustrates a central T-GM (Timing and Synchronization Manager) connected to a GNSS Simulator and a Frequency Reference. The T-GM is connected to O-DUs (O-DU1, O-DU2) and O-RUs (O-RU1, O-RU2) via O-DU UNI and O-RU UNI interfaces. The O-DUs and O-RUs are connected to Clock Testers. The Clock Testers are connected to the 1PPS measurement plane. The diagram also shows GNSS (PRTC-A) connections to O-RUs and O-DUs. Timing constraints are specified: |TE| ≤ 110ns for O-DU and O-RU connections, and 1PPS TE ≤ 110ns for the Clock Tester. Performance metrics are listed: Max TAE = 260ns, Max 1PPS TE ≤ 110ns at 1PPS Meas. Plane, and Max 1PPS TE ≤ 220ns at 1PPS Meas. Plane. + +The test topology above illustrates the placement of clock tester at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester. + +## Test Configuration + +1. T-GM, CSR, O-RUs and O-DUs are connected and configured as shown in the Test Topology. +2. Clock Tester at O-RU 1PPS measurement plane receives timing input on its measurement port. +3. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +4. GNSS (PRTC-A) is connected to O-RU and O-DUs. +5. G.8275.1 Full Timing Support profile. + +## Procedure: + +### Detailed Test procedure: + +1. GNSS (PRTC-A) is connected directly to O-RUs and O-DUs. +2. O-RU and O-DU use the GNSS (PRTC-A) as the primary clock source and use Time as backup from the T-GM at the central location. +3. Connect T-GM to GNSS Simulator and ensure that T-GM is locked. +4. Configure O-RU and O-DU as T-TSC and CSR as T-BC. +5. Enable G.8275.1 profile on all transport TNEs (CSR). +6. Connect Clock tester measurement ports to O-RU 1PPS monitor port to measure the 1PPS at measurement plane. +7. Establish PTP and Sync-E session to the fronthaul network. + +### Verifications for Maximum Absolute 1PPS Time Error + +1. Verify that PTP session is up and running between T-GM and CSR. +2. Verify that both O-RU and O-DU locked to GNSS (PRTC-A) as the primary clock source. +3. Verify the 1PPS time error measurements on Clock Tester at the 1PPS measurement plane. + - a. Max 1PPS $|TE|$ measured on Clock Tester at 1PPS measurement plane of O-RU $\leq 110ns$ + +### Verifications for Maximum Relative 1PPS Time Error + +1. Verify that PTP and Sync-E session is up and running. + +| | | | | | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|----------------|--| +| | <ol style="list-style-type: none"> <li>2. Verify that both O-RU and O-DU locked to GNSS (PRTC-A) as the primary clock source.</li> <li>3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs at 1PPS measurement plane. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 220ns</math></li> </ol> </li> </ol> <p>NOTE1:<br/>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | | | | +| | <b>Pass/Fail Criteria:</b> Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit | Expected Value | Observed Value | | +| | 1PPS $\max TE_L $ at 1PPS measurement plane | $\leq 110ns$ | | | +| | 1PPS $\max TE_{RL} $ at 1PPS measurement plane | $\leq 220ns$ | | | + +### 9.3.3 Network Time Synchronization-LLS-C4 and LLS-C3 mixed configurations for co-located DUs and RUs + +| | | | | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.5 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at 1PPS measurement plane of O-RU. LLS-C4 and LLS-C3 mixed configurations for co-located DUs and RUs. | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at 1PPS Measurement Plane of O-RUs.</li> <li>2. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at 1PPS Measurement Plane between O-RUs.</li> </ol> | | | +| <b>Pre-Req</b> | T-GM/PRTC connected to GNSS simulator and ensure T-GM is locked.<br>Tester 1PPS measurement port connected to O-RU/O-DU 1PPS out is the measurement plane. | | | + +## Test Topology: + +![Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, CSR, O-DUs, O-RUs, and Clock Testers. The diagram illustrates the 1PPS and 10MHz reference signals and the timing requirements for the 1PPS measurement plane.](fa3b02a006469db9e191869e9a715d6e_img.jpg) + +The diagram illustrates the test topology for 1PPS and 10MHz reference signals. A GNSS Simulator provides an RF Signal and a 1PPS Ref+10MHz Ref signal to a T-GM. The T-GM is connected to a CSR (T-BC/EEC/EEC) which in turn connects to O-DUs (T-TSC/EEC/EEC) and O-RUs (T-BC/EEC/EEC). The O-DUs are connected to O-RUs via O-DU UNI and O-RU UNI interfaces. Clock Testers are connected to the O-RUs at the 1PPS measurement plane. The diagram also shows the timing requirements for the 1PPS measurement plane, including the maximum time error (TE) and the maximum time error (TAE) for the 1PPS measurement plane. + +Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, CSR, O-DUs, O-RUs, and Clock Testers. The diagram illustrates the 1PPS and 10MHz reference signals and the timing requirements for the 1PPS measurement plane. + +The test topology above illustrates the placement of clock tester at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester. + +## Test Configuration + +1. T-GM, CSR, O-RUs and O-DUs are connected and configured as shown in the Test Topology. +2. Clock Tester at O-RU 1PPS measurement plane receives timing input on its measurement port. +3. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +4. GNSS (PRTC-A) is connected to O-RUs. +5. G.8275.1 Full Timing Support profile. + +## Procedure: + +### Detailed Test procedure: + +1. GNSS (PRTC-A) is connected directly to O-RUs. +2. O-RU use the GNSS (PRTC-A) as the primary clock source and use Time as backup from the T-GM at the central location. +3. O-DU lock to PTP clock from T-GM at the central location. +4. Connect T-GM to GNSS Simulator and ensure that T-GM is locked. +5. Configure O-RU and O-DU as T-TSC and CSR as T-BC. +6. Enable G.8275.1 profile on all transport TNEs (CSR). +7. Connect Clock tester measurement ports to O-RU 1PPS monitor port to measure the 1PPS at measurement plane. +8. Establish PTP and Sync-E session to the fronthaul network. + +### Verifications for Maximum Absolute 1PPS Time Error + +1. Verify that PTP session is up between GNSS (PRTC-A) and O-RU (T-TSC). +2. Verify that PTP session is up between T-GM, CSR (T-BC) and O-DU (T-TSC). +3. Verify that O-RU locked to GNSS (PRTC-A) as the primary clock source. +4. Verify the 1PPS time error measurements on Clock Tester at the 1PPS measurement plane. + - a. Max 1PPS $|TE_L|$ measured on Clock Tester at the 1PPS measurement plane of O-RU $\leq 110ns$ + +### Verifications for Maximum Relative 1PPS Time Error + +| | | | | | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------|----------------|--| +| <ol style="list-style-type: none"> <li>1. Verify that PTP and Sync-E session is up.</li> <li>2. Verify that both O-RU locked to GNSS (PRTC-A) as the primary clock source.</li> <li>3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs at 1PPS measurement plane. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 220ns</math></li> </ol> </li> </ol> <p>NOTE1:<br/>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | | | | | +| <b>Pass/Fail Criteria:</b> | | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | +| <b>Test Output</b> | End-to-End Network Limit | Expected Value | Observed Value | | +| | 1PPS $\max TE_L $ at 1PPS measurement plane | $\leq 110ns$ | | | +| | 1PPS $\max TE_{RL} $ at 1PPS measurement plane | $\leq 220ns$ | | | + +### 9.3.4 Network Time Synchronization-LLS-C4 and LLS-C3 mixed + +configurations for co-located DUs and RUs-GNSS Failure at O-RU site. + +| | | | | +|------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.6 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at 1PPS measurement plane of O-RU-LLS-C4 and LLS-C3 mixed configurations for co-located DUs and RUs. GNSS Failure at O-RU site. | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at 1PPS Measurement Plane of O-RUs.</li> <li>2. Verify the Maximum Relative 1PPS Time Error (<math>\max TE_{RL} </math>) at 1PPS Measurement Plane between O-RUs.</li> </ol> | | | +| <b>Pre-Req</b> | Test Case 9.3.5 MUST be a PASS. | | | + +## Test Topology: + +![Test Topology Diagram showing the connection between a Frequency Reference, GNSS Simulator, T-GM, O-DU, O-RU, and Clock Testers. The diagram illustrates the placement of clock tester at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester. Key components include: Frequency Reference, GNSS Simulator, T-GM (T-GM, CSR T-BC/EEC/eEEC), O-DU (O-DU1, O-DU2), O-RU (O-RU1, O-RU2), and Clock Testers. Connections are labeled with PTP Frequency Backup (orange) and Primary (blue). Performance metrics are listed: PRTC-A, |TE| ≤ 100ns; PRTC-B, |TE| ≤ 40ns; ePRTC, |TE| ≤ 30ns; |TE| ≤ 1100ns; 1PPS TE ≤ 110ns; Max TAE = 260ns; Max |1PPS TE_L| ≤ 110ns at 1PPS Meas. Plane; Max |1PPS TE_RL| ≤ 220ns at 1PPS Meas. Plane.](f6475de7113245bcca0894bcbb751e17_img.jpg) + +Test Topology Diagram showing the connection between a Frequency Reference, GNSS Simulator, T-GM, O-DU, O-RU, and Clock Testers. The diagram illustrates the placement of clock tester at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester. Key components include: Frequency Reference, GNSS Simulator, T-GM (T-GM, CSR T-BC/EEC/eEEC), O-DU (O-DU1, O-DU2), O-RU (O-RU1, O-RU2), and Clock Testers. Connections are labeled with PTP Frequency Backup (orange) and Primary (blue). Performance metrics are listed: PRTC-A, |TE| ≤ 100ns; PRTC-B, |TE| ≤ 40ns; ePRTC, |TE| ≤ 30ns; |TE| ≤ 1100ns; 1PPS TE ≤ 110ns; Max TAE = 260ns; Max |1PPS TE\_L| ≤ 110ns at 1PPS Meas. Plane; Max |1PPS TE\_RL| ≤ 220ns at 1PPS Meas. Plane. + +The test topology above illustrates the placement of clock tester at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester. + +## Test Configuration + +1. FAIL the GNSS connected to O-RU1 and O-RU2. + +## Procedure: + +### Verifications for Maximum Absolute 1PPS Time Error + +1. Verify that PTP session is down between GNSS (PRTC-A) and O-RU (T-TSC). +2. Verify that PTP session is up between T-GM, CSR (T-BC) and O-RU (T-TSC). +3. Verify that O-RU is locked to PTP Frequency from T-GM. +4. Verify the 1PPS time error measurements on Clock Tester at the 1PPS measurement plane. (O-RU should be in Phase-holdover using frequency from Backup T-GM) + - a. Max 1PPS $|TE_L|$ measured on Clock Tester at the 1PPS measurement plane of O-RU $\le 110\text{ns}$ (NOTE2) + +### Verifications for Maximum Relative 1PPS Time Error + +1. Verify that PTP and Sync-E session is up. +2. Verify that both O-RU locked to PTP Frequency from T-GM. +3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs at 1PPS measurement plane. + - a. $\max |TE_{RL}| (1,2) \le 220\text{ns}$ + +#### NOTE1: + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### NOTE2: + +O-RU in this topology is LLS-C4 O-RU as defined in the CUS specification [O-RAN.WG4.CUS.0-R003-v12.00, Section 11.3.2.3] and as such Note 3 and Note 4 apply. The Limit 110ns of phase error when GNSS fails with frequency assist from backup PTP is an assumption and the allowable limits are not yet defined for LLS-C4. + +## Pass/Fail Criteria: + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. + +## Test Output + +| | | | +|--|----------------|--| +| | Expected Value | | +|--|----------------|--| + +| End-to-End<br>Network Limit | | Observed<br>Value | +|------------------------------------------------|-------------|-------------------| +| 1PPS $\max TE_L $ at 1PPS measurement plane | $\le 110ns$ | | +| 1PPS $\max TE_{RL} $ at 1PPS measurement plane | $\le 220ns$ | | + +### 9.3.5 Network Time Synchronization-LLS-C4 and LLS-C3 mixed + +configurations with backup from redundant T-GM for co-located DUs and RUs + +| Test ID | SYNC.TE.7 | Classification | Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------| +| Test Title | Measurement of Absolute Time Error, Relative Time Error at 1PPS measurement plane of O-RU. LLS-C4 and LLS-C3 mixed configurations with backup from redundant T-GM for co-located DUs and RUs. | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute 1PPS Time Error (<math>\text{Max} TE_L </math>) at 1PPS Measurement Plane of O-RUs.</li> <li>2. Verify the Maximum Relative 1PPS Time Error (<math>\text{Max} TE_{RL} </math>) at 1PPS Measurement Plane between O-RUs.</li> </ol> | | | +| Pre-Req | T-GM/PRTC connected to GNSS simulator and ensure T-GM is locked.<br>Tester 1PPS measurement port connected to O-RU/O-DU 1PPS out is the measurement plane.<br>T-GM-A Priority-2 better than that of T-GM-B | | | + +#### Test Topology: + +![Test Topology Diagram showing the setup for Network Time Synchronization. The diagram illustrates a central O-RAN network (O-DU and O-RU) connected to a GNSS Simulator and a Frequency Reference. The O-DU and O-RU are connected to T-GM-A and T-GM-B, which are connected to the GNSS Simulator. The O-DU and O-RU are also connected to O-DU UNI and O-RU UNI, which are connected to O-DU1, O-DU2, O-RU1, and O-RU2. These are connected to T-TSC/REC/EEC and T-BC/T-TG/EEC/EEC blocks. The O-DU and O-RU are connected to 1PPS out and 1PPS in ports, which are connected to Clock Testers. The diagram includes various time error (TE) and time error rate (TER) constraints, such as |TE| ≤ 110ns and |TER| ≤ 110ns. A legend indicates Primary (blue) and Backup (orange) connections.](8c91cfc2ea1cf69527842107b7d5e027_img.jpg) + +The test topology above illustrates the placement of clock tester at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester. + +Test Topology Diagram showing the setup for Network Time Synchronization. The diagram illustrates a central O-RAN network (O-DU and O-RU) connected to a GNSS Simulator and a Frequency Reference. The O-DU and O-RU are connected to T-GM-A and T-GM-B, which are connected to the GNSS Simulator. The O-DU and O-RU are also connected to O-DU UNI and O-RU UNI, which are connected to O-DU1, O-DU2, O-RU1, and O-RU2. These are connected to T-TSC/REC/EEC and T-BC/T-TG/EEC/EEC blocks. The O-DU and O-RU are connected to 1PPS out and 1PPS in ports, which are connected to Clock Testers. The diagram includes various time error (TE) and time error rate (TER) constraints, such as |TE| ≤ 110ns and |TER| ≤ 110ns. A legend indicates Primary (blue) and Backup (orange) connections. + +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. T-GM-A, T-GM-B, CSR, O-RUs and O-DUs are connected and configured as shown in the Test Topology.</li> <li>2. Clock Tester at O-RU 1PPS measurement plane receives timing input on its measurement port.</li> <li>3. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>4. GNSS (PRTC-A) is connected to O-RU and O-DUs.</li> <li>5. G.8275.1 Full Timing Support profile.</li> </ol> | | | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------|----------------|----------------|---------------------------|--------------|--| +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. GNSS (PRTC-A) is connected directly to O-RUs.</li> <li>2. O-RU use the GNSS (PRTC-A) as the primary clock source and use PTP Time as backup from the T-GM-B at the central location.</li> <li>3. O-DU use the T-GM-A as the Primary Clock Source.</li> <li>4. Connect T-GM-A and T-GM-B to GNSS Simulator and ensure that they are locked.</li> <li>5. Configure O-RU and O-DU as T-TSC and CSR as T-BC.</li> <li>6. Enable G.8275.1 profile on all transport TNEs (CSR).</li> <li>7. Connect Clock tester measurement ports to O-RU 1PPS monitor port to measure the 1PPS at measurement plane.</li> <li>8. Establish PTP and Sync-E session to the fronthaul network.</li> </ol> <p><b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP session is up between GNSS (PRTC-A) and O-RU (T-TSC).</li> <li>2. Verify that PTP session is up between T-GM-A, T-GM-B, CSR (T-BC) and O-DU (T-TSC).</li> <li>3. Verify that O-RU locked to GNSS (PRTC-A) as the primary clock source.</li> <li>4. Verify the 1PPS time error measurements on Clock Tester at the 1PPS measurement plane. <ol style="list-style-type: none"> <li>a. Max 1PPS <math> TE_L </math> measured on Clock Tester at the 1PPS measurement plane of O-RU <math>\leq 110ns</math></li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that PTP and Sync-E session is up.</li> <li>2. Verify that both O-RU locked to GNSS (PRTC-A) as the primary clock source.</li> <li>3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs at 1PPS measurement plane. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 220ns</math></li> </ol> </li> </ol> <p>NOTE1:<br/>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | | | | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | | | | +| <b>Test Output</b> | <table border="1"> <tr> <th data-bbox="416 1921 683 2004">End-to-End Network Limit</th> <th data-bbox="683 1921 900 2004">Expected Value</th> <th data-bbox="900 1921 1117 2004">Observed Value</th> </tr> <tr> <td data-bbox="416 2004 683 2063">1PPS max<math> TE_L </math> at 1PPS</td> <td data-bbox="683 2004 900 2063"><math>\leq 110ns</math></td> <td data-bbox="900 2004 1117 2063"></td> </tr> </table> | End-to-End Network Limit | Expected Value | Observed Value | 1PPS max $ TE_L $ at 1PPS | $\leq 110ns$ | | +| End-to-End Network Limit | Expected Value | Observed Value | | | | | | +| 1PPS max $ TE_L $ at 1PPS | $\leq 110ns$ | | | | | | | + +| | | | | | +|--|------------------------------------------------|--------------|--|--| +| | measurement plane | | | | +| | 1PPS max $ TE_{RL} $ at 1PPS measurement plane | $\leq 220ns$ | | | + +### 9.3.6 Network Time Synchronization-LLS-C4 and LLS-C3 mixed configurations with backup from redundant T-GM for co-located DUs and RUs (GNSS Failure at O-RU site). + +| | | | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.8 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at 1PPS measurement plane of O-RU. LLS-C4 and LLS-C3 mixed configurations with backup from redundant T-GM for co-located DUs and RUs (GNSS Failure at O-RU site). | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at 1PPS Measurement Plane of O-RUs.</li> <li>Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at 1PPS Measurement Plane between O-RUs.</li> </ol> | | | +| <b>Pre-Req</b> | Test Case 9.3.7 MUST be a PASS.<br>T-GM-A Priority-2 better than that of T-GM-B | | | +| <b>Test Topology:</b> | <p>Image: Test Topology Diagram: A central dashed circle contains T-GM-A and T-GM-B, each connected to a CSR (T-BC/EEC/EEC). These CSRs connect to O-DU UNIs (O-DU1, O-DU2) and O-RU UNIs (O-RU1, O-RU2). O-DU UNIs connect to Clock Testers. O-RU UNIs connect to Clock Testers. A GNSS Simulator provides RF signals to T-GM-A and T-GM-B. A Frequency Reference provides 1PPS Ref+10MHz Ref to T-GM-A and T-GM-B. A GNSS signal is shown failing at the O-RU site. Performance metrics are listed: Max TAE < 360ns, Max 1PPS TE_L < 1480ns at 1PPS Meas. Plane, Max 1PPS TE_RL < 220ns at 1PPS Meas. Plane. Time error constraints are also shown: TE < 1100ns between T-GM and O-DU, and TE < 1100ns between T-GM and O-RU.</p> <p>The test topology above illustrates the placement of clock tester at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester.</p> | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>FAIL the GNSS connection to O-RU1 and O-RU2.</li> </ol> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>O-RU use Time as backup from the T-GM-A at the central location.</li> </ol> <p><b>Verifications for Maximum Absolute 1PPS Time Error</b></p> <ol style="list-style-type: none"> <li>Verify that PTP session is up between T-GM-A, T-GM-B, CSR (T-BC) and O-DU (T-TSC).</li> </ol> | | | + +2. Verify that O-RU locked to T-GM-A as the clock source. +3. Verify the 1PPS time error measurements on Clock Tester at the 1PPS measurement plane. + - a. Max 1PPS $|TE_L|$ measured on Clock Tester at the 1PPS measurement plane of O-RU $\leq 1480ns$ + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and Sync-E session is up. +2. Verify that both O-RU locked to T-GM-A as the primary clock source. +3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs at 1PPS measurement plane. + - a. $\max|TE_{RL}|(1,2) \leq 220ns$ + +#### **NOTE1:** + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +| | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------|----------------|----------------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | +| <b>Test Output</b> | End-to-End Network Limit | Expected Value | Observed Value | +| | 1PPS $\max TE_L $ at 1PPS measurement plane | $\leq 1480ns$ | | +| | 1PPS $\max TE_{RL} $ at 1PPS measurement plane | $\leq 220ns$ | | + +### 9.3.7 Network Time Synchronization-LLS-C4 and LLS-C3 mixed + +configurations with backup from redundant T-GM for co-located DUs and RUs (GNSS & T-GM-A Failure). + +| | | | | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.9 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at 1PPS measurement plane of O-RU. LLS-C4 and LLS-C3 mixed configurations with backup from redundant T-GM for co-located DUs and RUs (GNSS & T-GM-A Failure). | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at 1PPS Measurement Plane of O-RUs.</li> <li>2. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at 1PPS Measurement Plane between O-RUs.</li> </ol> | | | +| <b>Pre-Req</b> | Test Case 9.3.8 MUST be a PASS.<br>T-GM-A Priority-2 better than that of T-GM-B | | | + +## Test Topology: + +![Test Topology Diagram showing the placement of clock tester at the 1PPS measurement plane. The diagram illustrates a network topology with a central O-DU and O-RU, connected to T-GM-A and T-GM-B. A Frequency Reference and GNSS Simulator provide signals to the network. Clock Testers are connected to the O-RU and O-DU. The diagram shows the 1PPS and 10MHz reference signals connected to the clock tester. The diagram also shows the 1PPS measurement plane and the 1PPS output. The diagram includes a legend for Primary (blue arrow) and Backup (orange arrow) connections. The diagram also shows the 1PPS measurement plane and the 1PPS output. The diagram includes a legend for Primary (blue arrow) and Backup (orange arrow) connections. The diagram also shows the 1PPS measurement plane and the 1PPS output. The diagram includes a legend for Primary (blue arrow) and Backup (orange arrow) connections.](e769c6913197653d6c181564abf75c25_img.jpg) + +Test Topology Diagram showing the placement of clock tester at the 1PPS measurement plane. The diagram illustrates a network topology with a central O-DU and O-RU, connected to T-GM-A and T-GM-B. A Frequency Reference and GNSS Simulator provide signals to the network. Clock Testers are connected to the O-RU and O-DU. The diagram shows the 1PPS and 10MHz reference signals connected to the clock tester. The diagram also shows the 1PPS measurement plane and the 1PPS output. The diagram includes a legend for Primary (blue arrow) and Backup (orange arrow) connections. The diagram also shows the 1PPS measurement plane and the 1PPS output. The diagram includes a legend for Primary (blue arrow) and Backup (orange arrow) connections. The diagram also shows the 1PPS measurement plane and the 1PPS output. The diagram includes a legend for Primary (blue arrow) and Backup (orange arrow) connections. + +The test topology above illustrates the placement of clock tester at the 1PPS measurement plane with 1PPS and 10MHz reference connected to clock tester. + +## Test Configuration + +1. FAIL the GNSS connection to T-GM-A. + +## Procedure: + +### Detailed Test procedure: + +1. O-RU and O-DU use T-GM-B as backup. + +### Verifications for Maximum Absolute 1PPS Time Error + +1. Verify that PTP session is up between T-GM-B, CSR (T-BC) and O-DU (T-TSC). +2. Verify that O-RU locked to T-GM-B as the primary clock source. +3. Verify the 1PPS time error measurements on Clock Tester at the 1PPS measurement plane. + - a. Max 1PPS $|TE_L|$ measured on Clock Tester at the 1PPS measurement plane of O-RU $\leq 1480ns$ + +### Verifications for Maximum Relative 1PPS Time Error + +1. Verify that PTP and Sync-E session is up. +2. Verify that both O-RU locked to T-GM-A as the primary clock source. +3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs at 1PPS measurement plane. + - a. $\max|1PPS TE_{RL}|(1,2) \leq 220ns$ + +### NOTE1: + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +## Pass/Fail Criteria: + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. + +## Test Output + +| End-to-End Network Limit | Expected Value | Observed Value | +|---------------------------------------------|----------------|----------------| +| 1PPS $\max TE_L $ at 1PPS measurement plane | $\leq 1480ns$ | | + +| | | | | | +|--|------------------------------------------------|--------------|--|--| +| | 1PPS max $ TE_{RL} $ at 1PPS measurement plane | $\leq 220ns$ | | | +|--|------------------------------------------------|--------------|--|--| + +### 9.3.8 Network Time Synchronization-LLS-C3 configurations with GNSS assisted CSR for co-located DUs and RUs + +| | | | | +|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.10 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at measurement plane of O-RU. LLS-C3 configurations with GNSS assisted CSR for co-located DUs and RUs. | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at O-RU UN.</li> <li>5. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | T-GM/PRTC connected to GNSS simulator and ensure T-GM is locked.<br>O-RU UNI is the measurement plane. | | | +| <b>Test Topology:</b> | <p>Image: Test Topology Diagram: A central dashed circle represents the O-RU. Inside, a T-GM block is connected to a T-BC block. The T-BC block is connected to two O-DU blocks (O-DU1 and O-DU2) on the left and two CSR blocks (CSR1 and CSR2) on the right. Each O-DU and CSR block is connected to a Clock Tester block outside the circle. A GNSS simulator at the top provides an RF signal to the T-GM and a 1PPS Ref+10MHz Ref signal to the Clock Testers. GNSS signals are also shown entering the O-DU and CSR blocks. A legend indicates Primary (blue arrow) and PTP Frequency Backup (orange arrow) connections. Performance metrics are listed for Enhanced RU (ERL-ER2) and Regular RU (ER1).</p> <p>The test topology above illustrates the placement of clock tester at the O-RU UNI measurement plane with 1PPS and 10MHz reference connected to clock tester.</p> | | | +| <b>Test Configuration</b> | <ol style="list-style-type: none"> <li>1. T-GM, CSR, O-RUs and O-DUs are connected and configured as shown in the Test Topology.</li> <li>2. Clock Tester at O-RU UNI measurement plane receives timing input on its measurement port.</li> <li>3. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>4. GNSS is connected to O-RU and O-DUs.</li> <li>5. G.8275.1 Full Timing Support profile.</li> </ol> | | | + +## Procedure: + +### Detailed Test procedure: + +1. GNSS (PRTC-A) is connected directly to O-RUs and O-DUs. +2. Both O-RU and O-DU use the GNSS (PRTC-A) as the primary clock source and use Time as backup from the T-GM at the central location. +3. Connect T-GM to GNSS Simulator and ensure that they are locked. +4. Configure O-DU as T-TSC and CSR as T-BC. +5. Enable G.8275.1 profile on all transport TNEs (CSR). +6. Connect Clock tester measurement ports to O-RU 1PPS monitor port to measure the 1PPS at O-RU UNI. +7. Establish PTP and Sync-E session to the fronthaul network. + +### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM, CSR (T-BC) and O-DU (T-TSC). +2. Verify that O-DU is locked to GNSS. +3. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\text{Max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 100ns$ (For Enhanced RU) + - b. $\text{Max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 100ns$ (For Regular RU) + +### Verifications for Maximum Relative Packet Time Error + +1. Verify that PTP and Sync-E session is up. +2. Verify that CSR locked to T-GM as the clock source. +3. Verify the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\text{max}|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\text{max}|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\text{max}|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +### Verifications for Maximum Absolute 1PPS Time Error + +1. Verify that PTP session is up between GNSS (PRTC-A) and O-RU (T-TSC). +2. Verify that PTP session is up between T-GM, CSR (T-BC) and O-DU (T-TSC). +3. Verify that O-RU locked to GNSS (PRTC-A) as the primary clock source. +4. Verify the 1PPS time error measurements on Clock Tester at O-RU UNI. + - a. Max 1PPS $|TE_L|$ measured on Clock Tester at O-RU UNI $\leq 100ns$ (For Enhanced RU) + - b. Max 1PPS $|TE_L|$ measured on Clock Tester at O-RU UNI $\leq 100ns$ (For Regular RU) + +### Verifications for Maximum Relative 1PPS Time Error + +1. Verify that PTP and Sync-E session is up. +2. Verify that both O-RU locked to GNSS (PRTC-A) as the primary clock source. +3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs UNI. + - a. $\text{max}|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\text{max}|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + +| | | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------|-------------------|----------------| +| | <p>c. <math>\max TE_{RL} (1,2) \leq 100ns (FR1)</math> (For Regular RU)</p> <p>NOTE1:<br/>To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other.</p> | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 100ns$ | $\leq 100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | 1PPS $\max TE_L $ | $\leq 100ns$ | $\leq 100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +### 9.3.9 Network Time Synchronization-LLS-C3 configurations with (GNSS+PRTC) assisted CSR for co-located DUs and RUs + +| | | | | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.11 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at measurement plane of O-RU UNI. LLS-C3 configurations with (GNSS+PRTC) assisted CSR for co-located DUs and RUs. | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>\max TE_{RL} </math>) at O-RU UN.</li> <li>5. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <p>T-GM/PRTC connected to GNSS simulator and ensure T-GM is locked.</p> <p>Tester at O-RU UNI is the measurement plane.</p> | | | + +## Test Topology: + +![Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, O-DUs, CSRs, and O-RUs, with clock testers at the O-RU UNI. The diagram includes timing constraints for PRTC, T-GM, O-DU, and CSR components.](1c4d5f30325062ca1f139ed59ca187c0_img.jpg) + +The diagram illustrates the test topology for clock synchronization. A central T-GM (Timing and Synchronization Manager) is connected to a GNSS Simulator and a Frequency Reference. The T-GM is connected to O-DUs (O-DU1, O-DU2) and CSRs (CSR1, CSR2). The O-DUs are connected to O-RUs (O-RU1, O-RU2). The O-RUs are connected to clock testers. The clock testers are connected to the O-RU UNI. The diagram includes timing constraints for PRTC, T-GM, O-DU, and CSR components. + +Timing Constraints: + +- PRTC-A, $|TE| \leq 100\text{ns}$ +- PRTC-B, $|TE| \leq 40\text{ns}$ +- ePRTC, $|TE| \leq 30\text{ns}$ +- T-GM, $|TE| \leq 1100\text{ns}$ +- O-DU, $|TE| \leq 1100\text{ns}$ +- CSR, $|TE| \leq 1100\text{ns}$ +- O-RU, $|TE| \leq 1100\text{ns}$ +- 1PPS TE, $|TE| \leq 100\text{ns}$ +- 10MHz TE, $|TE| \leq 100\text{ns}$ +- 1PPS out, $|TE| \leq 100\text{ns}$ +- 10MHz out, $|TE| \leq 100\text{ns}$ +- GNSS, $|TE| \leq 100\text{ns}$ + +Test Topology Diagram showing the connection between a GNSS Simulator, T-GM, O-DUs, CSRs, and O-RUs, with clock testers at the O-RU UNI. The diagram includes timing constraints for PRTC, T-GM, O-DU, and CSR components. + +The test topology above illustrates the placement of clock tester at the O-RU UNI measurement plane with 1PPS and 10MHz reference connected to clock tester. + +## Test Configuration + +1. T-GM, CSR, O-RUs and O-DUs are connected and configured as shown in the Test Topology. +2. Clock Tester at O-RU UNI receives timing input on its measurement port. +3. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator. +4. GNSS is connected to O-RU and O-DUs. +5. G.8275.1 Full Timing Support profile. + +## Procedure: + +### Detailed Test procedure: + +1. GNSS via PRTC is connected directly to CSRs. +2. Connect 1PPS, TOD, 10MHz cable from PRTC to CSR. +3. CSR use the (GNSS + PRTC) as the primary clock source and backup from the T-GM at the central location. +4. O-DU use the GNSS (PRTC-A) as the Primary Clock Source. +5. Connect T-GM to GNSS Simulator and ensure that they are locked. +6. Configure O-DU as T-TSC and CSR as T-BC. +7. Enable G.8275.1 profile on all transport TNEs (CSR). +8. Connect Clock tester measurement ports to CSR 1PPS monitor port to measure the 1PPS at O-RU UNI. +9. Establish PTP and Sync-E session to the fronthaul network. + +### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM, CSR (T-BC) and O-DU (T-TSC). +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\text{Max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 100\text{ns}$ (For Enhanced RU) + - b. $\text{Max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 100\text{ns}$ (For Regular RU) + +### **Verifications for Maximum Relative Packet Time Error** + +1. Verify that PTP and Sync-E session is up. +2. Verify that CSR locked to T-GM as the clock source. +3. Verify the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up between (GNSS + PRTC) and CSR (T-BC). +2. Verify that CSR locked to GNSS (PRTC-A) as the primary clock source. +3. Verify the 1PPS time error measurements on Clock Tester at the O-RU UNI. + - a. Max 1PPS $|TE_L|$ measured on Clock Tester at O-RU UNI $\leq 100ns$ (For Enhanced RU) + - b. Max 1PPS $|TE_L|$ measured on Clock Tester at O-RU UNI $\leq 100ns$ (For Regular RU) + +### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and Sync-E session is up. +2. Verify that CSR locked to (GNSS+PRTC) as the primary clock source. +3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs UNI. + - a. $\max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +NOTE1: + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +### **Pass/Fail Criteria:** + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. + +### **Test Output** + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|--------------------|--------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 100ns$ | $\leq 100ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| 1PPS $\max TE_L $ | $\leq 100ns$ | $\leq 100ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +### 9.3.10 Network Time Synchronization-LLS-C3 configurations with GNSS assisted CSR with backup from redundant T-GM for co-located DUs and RUs + +| Test ID | SYNC.TE.12 | Classification | Synchronization, Performance, Absolute Time Error, Relative Time Error | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------| +| Test Title | Measurement of Absolute Time Error, Relative Time Error at measurement plane of O-RU UNI. LLS-C3 configurations with GNSS assisted CSR with backup from redundant T-GM for co-located DUs and RUs. | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) at O-RU UN.</li> <li>5. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| Pre-Req | <p>T-GM/PRTC connected to GNSS simulator and ensure T-GM is locked.</p> <p>Tester at the O-RU UNI is the measurement plane.</p> <p>T-GM-A Priority-2 better than that of T-GM-B</p> | | | +| Test Topology: | <p>Image: Test Topology Diagram: A central dashed circle represents the O-RU. Inside, T-GM-A and T-GM-B are connected to T-BC (T-BC/EEC/EEC). T-BC is connected to O-DU1 and O-DU2. O-DU1 and O-DU2 are connected to Clock Testers. A Frequency Reference and GNSS Simulator provide 1PPS and 10MHz references. The diagram shows primary (blue) and backup (orange) paths. Performance metrics are listed for Enhanced RU (FR1-FR2) and Regular RU (FR1).</p> <p>The test topology above illustrates the placement of clock tester at the O-RU UNI with 1PPS and 10MHz reference connected to clock tester.</p> | | | +| Test Configuration | <ol style="list-style-type: none"> <li>1. T-GM-A, T-GM-B, CSR, O-RUs and O-DUs are connected and configured as shown in the Test Topology.</li> <li>2. Clock Tester at O-RU UNI measurement plane receives timing input on its measurement port.</li> <li>3. Provide 1PPS and 10MHz reference to Clock Tester from GNSS simulator.</li> <li>4. GNSS is connected to O-RU and O-DUs.</li> <li>5. G.8275.1 Full Timing Support profile.</li> </ol> | | | + +**Procedure:** +**Detailed Test procedure:** + +1. GNSS (PRTC-A) is connected directly to CSRs. +2. CSR use the GNSS (PRTC-A) as the primary clock source and use Time as backup from the T-GM-B at the central location. +3. O-DU use the T-GM-A as the Primary Clock Source. +4. Configure O-RU and O-DU as T-TSC and CSR as T-BC. +5. Enable G.8275.1 profile on all transport TNEs (CSR). +6. Connect Clock tester measurement ports to CSR 1PPS monitor port to measure the 1PPS at measurement plane. +7. Establish PTP and Sync-E session to the fronthaul network. + +**Verifications for Maximum Absolute Packet Time Error** + +1. Verify that PTP session is up and running between T-GM-A, T-GM-B, CSR (T-BC) and O-DU (T-TSC). +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\text{Max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 100ns$ (For Enhanced RU) + - b. $\text{Max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 100ns$ (For Regular RU) + +**Verifications for Maximum Relative Packet Time Error** + +1. Verify that PTP and Sync-E session is up. +2. Verify that CSR locked to T-GM-A as the clock source. +3. Verify the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\text{max}|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\text{max}|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\text{max}|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +**Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify that PTP session is up between GNSS (PRTC-A) and CSR (T-BC). +2. Verify that CSR locked to T-GM-A as the primary clock source. +3. Verify the 1PPS time error measurements on Clock Tester at the O-RU UNI. + - a. Max 1PPS $|TE_L|$ measured on Clock Tester O-RU UNI $\leq 100ns$ (For Enhanced RU) + - b. Max 1PPS $|TE_L|$ measured on Clock Tester at O-RU UNI $\leq 100ns$ (For Regular RU) + +**Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and Sync-E session is up. +2. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs UNI. + - a. $\text{max}|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\text{max}|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\text{max}|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +NOTE1: + +| | | | | | +|--------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------|-------------------|----------------| +| | To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. | | | | +| | <b>Pass/Fail Criteria:</b> Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 100ns$ | $\leq 100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | 1PPS $\max TE_L $ | $\leq 100ns$ | $\leq 100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +### 9.3.11 Network Time Synchronization-LLS-C3 configurations with GNSS + +assisted CSR with backup from redundant T-GM for co-located DUs and RUs (GNSS Failure at CSR site) + +| | | | | +|------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.13 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at measurement plane of O-RU. LLS-C3 configurations with GNSS assisted CSR with backup from redundant T-GM for co-located DUs and Rus (GNSS Failure at RU site). | | | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between the O-RU UNI ports.</li> <li>3. Verify the Maximum Absolute 1PPS Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>4. Verify the Maximum Relative 1PPS Time Error (<math>\max TE_{RL} </math>) at O-RU UN.</li> <li>5. Verify the Time Wander at O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | O-RU UNI is the measurement plane.<br>Testcase 9.3.12 MUST be a PASS.<br>T-GM-A Priority-2 better than that of T-GM-B | | | + +## Test Topology: + +![Test Topology Diagram showing the connection between a Frequency Reference, GNSS Simulator, T-GM-A, T-GM-B, O-DU, O-RU, and Clock Testers. The diagram includes various timing constraints and reference signals.](f0c8e72eedba6c3337fd743729a4555b_img.jpg) + +The diagram illustrates the test topology for clock synchronization. It shows a central O-DU (Orange Distributed Unit) connected to T-GM-A and T-GM-B (Timing and Synchronization Modules). The O-DU is connected to O-RU (Orange Radio Unit) via O-DU UNI and O-RU UNI. The O-RU is connected to two Clock Testers. The diagram includes various timing constraints and reference signals. + +Timing Constraints: + +- $|TE| \leq 100ns$ (PRTC-A) +- $|TE| \leq 40ns$ (PRTC-B) +- $|TE| \leq 30ns$ (ePRTC) +- $|TE| \leq 1100ns$ (O-DU to O-RU) +- $|TE| \leq 1100ns$ (O-RU to O-RU) + +Reference Signals: + +- 1PPS Ref+10MHz Ref +- GNSS +- 1PPS out + +Legend: + +- Primary (Blue arrow) +- Backup (Orange arrow) + +Performance Requirements: + +- For Enhanced RU (FR2-FR1): + - Max $|TE_{RL}| \leq 60-190ns$ at O-RU UNI + - Max $|TE_{RL}| \leq 130-260ns$ + - Max $|1PPS TE_L| \leq 1100ns$ at O-RU UNI + - Max $|1PPS TE_{RL}| \leq 60-190ns$ at O-RU UNI +- For Regular RU (FR1): + - Max $|TE_{RL}| \leq 100ns$ at O-RU UNI + - Max $|TE_{RL}| \leq 260ns$ + - Max $|1PPS TE_L| \leq 1100ns$ at O-RU UNI + - Max $|1PPS TE_{RL}| \leq 100ns$ at O-RU UNI + +Test Topology Diagram showing the connection between a Frequency Reference, GNSS Simulator, T-GM-A, T-GM-B, O-DU, O-RU, and Clock Testers. The diagram includes various timing constraints and reference signals. + +The test topology above illustrates the placement of clock tester at the O-RU UNI with 1PPS and 10MHz reference connected to clock tester. + +## Test Configuration + +1. Fail the GNSS connection to CSRs. + +## Procedure: + +### Detailed Test procedure: + +1. CSR and O-DU use the T-GM-A as the clock source. +2. Connect Clock tester measurement ports to CSR 1PPS monitor port to measure the 1PPS at O-RU UNI. +3. Establish PTP and Sync-E session to the fronthaul network. + +### Verifications for Maximum Absolute Packet Time Error + +1. Verify that PTP session is up and running between T-GM-A, T-GM-B, CSR (T-BC) and O-DU (T-TSC). +2. Verify that O-DU is locked to T-GM-A via CSR. +3. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $\text{Max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\text{Max}|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +### Verifications for Maximum Relative Packet Time Error + +1. Verify that PTP and Sync-E session is up. +2. Verify that CSR locked to T-GM-A as the clock source. +3. Verify the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $\text{max}|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\text{max}|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\text{max}|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +### Verifications for Maximum Absolute 1PPS Time Error + +1. Verify that PTP session is up between T-GM-A, T-GM-B, CSR (T-BC) and O-DU (T-TSC). +2. Verify that CSR locked to T-GM-A as the clock source. + +3. Verify the 1PPS time error measurements on Clock Tester at the 1PPS measurement plane. + - a. Max 1PPS $|TE_L|$ measured on Clock Tester at the 1PPS measurement plane of O-RU $\leq 1100ns$ (For Enhanced RU) + - b. Max 1PPS $|TE_L|$ measured on Clock Tester at the 1PPS measurement plane of O-RU $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and Sync-E session is up. +2. Verify that CSR locked to T-GM-A as the clock source. +3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs UNI. + - a. $\max|1PPS\ TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\max|1PPS\ TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\max|1PPS\ TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **NOTE1:** + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### **Pass/Fail Criteria:** + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. + +#### **Test Output** + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|-------------------|-------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +### 9.3.12 Network Time Synchronization-LLS-C3 configurations with GNSS assisted CSR with backup from redundant T-GM for co-located DUs and RUs (GNSS Failure at CSR site and T-GM-A Failure) + +| Test ID | SYNC.TE.14 | Classification | Synchronization, Performance, Absolute Time Error, Relative Time Error | +|-----------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|------------------------------------------------------------------------| +| Test Title | Measurement of Absolute Time Error, Relative Time Error at measurement plane of O-RU UNI. LLS-C3 configurations with GNSS assisted CSR for co-located DUs and RUs (GNSS Failure). | | | +| Test Objective: | <ol style="list-style-type: none"> <li>1. Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at O-RU UNI.</li> <li>2. Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) between the O-RU UNI ports.</li> </ol> | | | + +3. Verify the Maximum Absolute 1PPS Time Error ( $Max|TE_L|$ ) at O-RU UNI. +4. Verify the Maximum Relative 1PPS Time Error ( $Max|TE_{RL}|$ ) at O-RU UNI. +5. Verify the Time Wander at O-RU UNI. + +#### Pre-Req + +O-RU UNI is the measurement plane. +Test Case 9.3.13 MUST be a PASS. +T-GM-A Priority-2 better than that of T-GM-B + +#### Test Topology: + +![Test Topology Diagram showing the connection between a Frequency Reference, GNSS Simulator, T-GM-A, T-GM-B, O-DU, CSR, and Clock Testers. The diagram illustrates the placement of clock testers at the O-RU UNI with 1PPS and 10MHz reference connected to clock tester. It includes various time error constraints like |TE| ≤ 1100ns and |TE_L| ≤ 100ns.](db4c6983f6afabb270b7cbcf12564f1d_img.jpg) + +The diagram illustrates the test topology for clock synchronization. A Frequency Reference (1PPS Ref+10MHz Ref) and a GNSS Simulator provide signals to T-GM-A and T-GM-B. T-GM-A is connected to O-DU1 and O-DU2 via T-BC/EEC/eEEC. T-GM-B is connected to CSR1 and CSR2 via T-BC/EEC/eEEC. O-DU1 and O-DU2 are connected to Clock Testers via 1PPS out. CSR1 and CSR2 are connected to Clock Testers via 1PPS out. The diagram also shows GNSS connections to O-RU UNI and various time error constraints: $|TE| \leq 1100ns$ , $|TE_L| \leq 100ns$ , and $|TE_{RL}| \leq 100ns$ . A legend indicates Primary (blue) and Backup (orange) connections. + +Test Topology Diagram showing the connection between a Frequency Reference, GNSS Simulator, T-GM-A, T-GM-B, O-DU, CSR, and Clock Testers. The diagram illustrates the placement of clock testers at the O-RU UNI with 1PPS and 10MHz reference connected to clock tester. It includes various time error constraints like |TE| ≤ 1100ns and |TE\_L| ≤ 100ns. + +The test topology above illustrates the placement of clock tester at the O-RU UNI with 1PPS and 10MHz reference connected to clock tester. + +#### Test Configuration + +FAIL the GNSS connection to T-GM-A. + +#### Procedure: + +##### Detailed Test procedure: + +1. O-DU and CSR use the T-GM-B as the Primary Clock Source. + +##### Verifications for Maximum Absolute Packet Time Error + +1. Verify that CSR is locked to T-GM-B. +2. Verify time error measurements using Clock Tester for the PTP flows from CSR at the O-RU UNI. + - a. $Max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $Max|TE_L|$ measured on Clock Tester at the O-RU UNI $\leq 1100ns$ (For Regular RU) + +##### Verifications for Maximum Relative Packet Time Error + +1. Verify that PTP and Sync-E session is up. +2. Verify that CSR locked to T-GM-B as the primary clock source. +3. Verify the Maximum Relative Time Error measurements between the O-RU UNI ports. + - a. $max|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $max|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $max|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +##### Verifications for Maximum Absolute 1PPS Time Error + +1. Verify that PTP session is down between GNSS (PRTC-A) and CSR (T-BC). +2. Verify that PTP session is up between T-GM-B, CSR (T-BC) and O-DU (T-TSC). +3. Verify that CSR locked to T-GM-B as the primary clock source. +4. Verify the 1PPS time error measurements on Clock Tester at O-RU UNI. + - a. Max 1PPS $|TE_L|$ measured on Clock Tester at O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. Max 1PPS $|TE_L|$ measured on Clock Tester at O-RU UNI $\leq 11000ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Verify that PTP and Sync-E session is up. +2. Verify that CSR locked to T-GM-B as the primary clock source. +3. Estimate the Maximum Relative 1PPS Time Error measurements between the O-RUs UNI. + - a. $\max|1PPS TE_{RL}| (1,2) \leq 60ns (FR2)$ (For Enhanced RU) + - b. $\max|1PPS TE_{RL}| (1,2) \leq 190ns (FR1)$ (For Enhanced RU) + - c. $\max|1PPS TE_{RL}| (1,2) \leq 100ns (FR1)$ (For Regular RU) + +NOTE1: + +To measure the relative time error, measure the time error from each point with respect to the internal time reference of measurement equipment, and then subtracting time error of one point from the other. + +#### **Pass/Fail Criteria:** + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. + +#### **Test Output** + +| End-to-End Network Limit at O-RU UNI | Expected Value | | Observed Value | +|--------------------------------------|-------------------|-------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | $\leq 190ns(FR1)$ | | | +| Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +1 + +2 + +3 + +4 + +5 + +6 + +## 9.4 Timing Solution use cases in LLS-C3 configuration for Shared O-RU + +This chapter specifies the test specification for a few use cases in LLS-C3 configurations for Shared O-RU. The test specification will address cases where two O-DUs connected to O-RUs (Shared O-RUs), via an Access Transport Networks (TN). On resiliency note, we are dealing with different elements (such as T-GM and HSR associated with an 'ACTIVE' O-DU) that have either partially or completely failed or when there are failures in the connected interfaces on the Transport Networks. + +A Shared O-RU maintains connectivity to more than one O-DUs, for example, two O-DUs, with one of them is considered as the 'ACTIVE' O-DU and other may be considered as the 'STANDBY' O-DU. + +It is also expected that an O-DU shall support multiple Shared O-RUs. For example, O-DU1 may be connected to O-RU1 and O-RU2; O-DU2 may also be connected to O-RU1 and O-RU2. If O-DU1 fails, both O-RUs switch to O-DU2. + +For the case of Shared O-RU with common transport, O-RU and Access Transport Network (TN) are all shared with a single Operator, however one or more O-DUs are managed by more than one SROs. For the Shared O-RU with separate transport, the O-RU is configured to operate with more than one Shared Resource Operators O-DUs and the associated access TN. + +For Shared O-RU using a common transport network managed by Shared O-RU host (SOH), the resiliency solution will not differ from the non-Shared O-RU. Hence the resiliency scenario is not discussed in this section. For Shared O-RU supported by separate transport networks that are managed by different SROs, each of SROs takes its own responsibility to the resiliency design to its transport network. + +The test specification assume that there are no failures on O-DUs and Shared O-RUs. The resiliency is based on the premise that there will always be redundant path operational for S-plane communications in the Access Transport Network between O-DUs and Shared O-RUs. + +The Shared O-RU use cases in high level are already mentioned in the O-RAN WG9 Synchronization Architecture and Solution Specification. Following use cases have been covered in this chapter and for each of these use cases, clock performance limits are discussed for normal and failover scenarios. + +LLS-C3 Configuration for Shared O-RU Use case. + +- a. A Shared O-RU using common transport with both O-DUs managed by different SROs. +- b. Shared O-RUs using separate transport with both O-DUs managed by different SROs. +- c. Shared O-RUs using separate transport with both O-DUs managed by different SROs (Link Failure on T-GM1). +- d. Shared O-RUs using separate transport with both O-DUs managed by different SROs (Redundant TN). +- e. Shared O-RUs using separate transport with both O-DUs managed by different SROs (Link Failure on HSR1). +- f. Shared O-RUs using separate transport with both O-DUs managed by different SROs (Full Redundancy). +- g. Shared O-RUs using separate transport with both O-DUs managed by different SROs (GM & HSR Failure). + +The performance limits at the input of Shared O-RU UNI for various Shared O-RU use cases mentioned above for LLS-C3 configuration remains same as that of non-Shared O-RU. Refer clause 14.3.1 in O-RAN.WG4.CUS.0-R003-v14.00 for details. However, it is important for each operator to design and manage the network to ensure LLS-C3 network limits are met under various network failover conditions. + +The test cases apply to both lab and field deployment cases. The test topologies in this section specify only few Transport Node Elements (TNEs) for illustration. However, for lab cases, the type and number of inserted Transport Node Elements (TNE) will be determined by operators (or any other applicable end customer) subject to the Shared O-RU UNI limits. The test in this section is performed at Shared O-RU UNI interfaces. + +The Test Topologies in all the test cases uses GNSS simulator to generate the GNSS signal to the network PRTC/T-GM. This high-quality reference from the simulator is used as the external reference for clock testers as well. The resultant accuracy of this method is a few nanoseconds. However, one can also use a GNSS signal feeding both the initial PRTC/T-GM in the network and the reference clock generating a 1pps/10MHz used to synchronize the clock testers for the measurements. Operator can make an allowance in this case, for all of the measurements for the accuracy of the reference. The magnitude of this allowance will depend on the specific GNSS reference in use. + +For relative time error measurements at UNI (e.g., Shared O-RU Fronthaul UNI) this document uses the metric $\max|TE_{RL}|$ (1,2) as defined in [88], Appendix XI. Please note this metric represents an estimation and the worst-case scenario. Tests that meet (are below) the limits are seen as PASS. Tests not meeting this metric may still be acceptable. The decision is for operators to make. However, if the measurement equipment support relative time error measurement, operator can use such equipment. Refer ITU-T G.8271.1 Appendix XI for more details. + +For Frequency Limit at UNI (e.g., Shared O-RU Fronthaul UNI) this document uses the metric defined as per WG4 section H.2 based on PRTC class for LLS-C3 configuration. Applicable MTIE limit shall apply for Frequency as per WG4 specification. + +#### 9.4.1 Timing Solution for Shared O-RU using common transport + +| Test ID | SYNC.TE.01 | Classification | Synchronization, Performance, Absolute Time Error, Relative Time Error, Shared O-RU | +|------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|-------------------------------------------------------------------------------------| +| Test Title | Measurement of Absolute Time Error, Relative Time Error at measurement plane of Shared O-RU UNI. | | | +| Test Description | <p>LLS-C3 configurations for Shared O-RU with common transport.</p> <p>A single Shared O-RU connected to two O-DUs via Access TN and O-DU1 and O-DU2 are managed by SRO-1 and SRO-2 respectively. No redundancy in the Access TN.</p> <p>Only SRO-1 has the host privilege. This means SRO-1 additionally acts as Shared O-RU host (SOH).</p> | | | +| Test Objective: | <ol style="list-style-type: none"> <li>Verify the Clock Lock states on O-DUs, HSRs and CSRs.</li> <li>Verify the steady-state clock attributes on O-DUs, HSRs and CSRs.</li> <li>Verify the Maximum Absolute Packet Time Error (<math>\max TE_L </math>) at Shared O-RU UNI.</li> <li>Verify the Maximum Relative Packet Time Error (<math>\max TE_{RL} </math>) at Shared O-RU UNI.</li> </ol> | | | + +5. Verify the Maximum Absolute 1PPS Time Error ( $Max|TE_L|$ ) at Shared O-RU UNI. +6. Verify the Maximum Relative 1PPS Time Error ( $Max|TE_{RL}|$ ) at Shared O-RU UNI. +7. Verify the Time Wander at Shared O-RU UNI. + +### Pre-Req + +O-RU with Shared O-RU Feature (Not shown in the diagram). + +Shared O-RU UNI is the measurement plane. + +T-GM, HSR, CSR1, CSR2 are part of common TN managed by SRO-1. + +O-DU1 and O-DU2 are managed by SRO-1 and SRO-2 respectively. + +Only SRO-1 has the host privilege. + +O-DU1 is the ACTIVE O-DU managed by SRO-1 and O-DU2 is the STANDBY O-DU managed by SRO-2. + +When the ACTIVE O-DU fails, the Shared O-RU helps identify the possible connectivity with STANDBY O-DU managed by SRO-2. + +### Test Topology: + +![Test Topology Diagram showing the connection between a GNSS Simulator, Frequency Reference, and various O-RU components (SRO-1, SRO-2, O-DU1, O-DU2, CSR1, CSR2) and Clock Testers. The diagram illustrates the flow of 1PPS and 10MHz reference signals and the measurement plane at the Shared O-RU UNI.](3b43765d5e86148ee98b64e49634ac58_img.jpg) + +The diagram illustrates the test topology for clock synchronization. A GNSS Simulator provides a 1PPS Ref+10MHz Ref signal to a Frequency Reference and an RF Signal to the T-GM SRO-1. The T-GM SRO-1 is connected to SRO-1 (HSR) and SRO-2 (O-DU2). SRO-1 (HSR) is connected to O-DU1 and O-DU2. O-DU1 and O-DU2 are connected to SRO-1 (O-DU1) and SRO-2 (O-DU2). SRO-1 (O-DU1) and SRO-2 (O-DU2) are connected to CSR1 and CSR2. CSR1 and CSR2 are connected to the Shared O-RU UNI. The Shared O-RU UNI is connected to two Clock Testers. The diagram also shows the measurement plane at the Shared O-RU UNI and the connection to the Access TN managed by the Shared O-RU host. + +Legend: + +- Primary (Blue arrow) +- SRO: Shared Resource Operator +- TN: Transport Network + +Performance Requirements: + +- For Enhanced RU (FR2-FR1): + - Max $|TE_{RL}| \leq 60-190ns$ at O-RU UNI + - Max $TAE \leq 150-260ns$ + - Max $|1PPS TE_L| \leq 1100ns$ at O-RU UNI + - Max $|1PPS TE_{RL}| \leq 60-190ns$ at O-RU UNI +- For Regular RU (FR1): + - Max $|TE_{RL}| \leq 100ns$ at O-RU UNI + - Max $TAE \leq 260ns$ + - Max $|1PPS TE_L| \leq 1100ns$ at O-RU UNI + - Max $|1PPS TE_{RL}| \leq 100ns$ at O-RU UNI + +Test Topology Diagram showing the connection between a GNSS Simulator, Frequency Reference, and various O-RU components (SRO-1, SRO-2, O-DU1, O-DU2, CSR1, CSR2) and Clock Testers. The diagram illustrates the flow of 1PPS and 10MHz reference signals and the measurement plane at the Shared O-RU UNI. + +The test topology above illustrates the placement of clock testers at the Shared O-RUs UNI connected to CSRs. 1PPS and 10MHz reference from GNSS Simulator connected to the clock reference inputs of the clock tester. + +### Test Configuration + +Configure G.8275.1 profile on all devices. + +### Procedure: + +#### Detailed Test procedure: + +1. HSR uses T-GM as the Primary Clock Source. +2. CSR1, CSR2, O-DU1 and O-DU2 are locked to HSR. + +#### Verifications for Clock Attributes + +1. Verify the clock lock states on O-DUs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the clock attributes on O-DUs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +#### Verifications for Maximum Absolute Packet Time Error + +1. Verify time error measurements using Clock Tester for the PTP flows from CSRs at the Shared O-RUs UNI. + - a. $Max|TE_L|$ measured on Clock Tester at Shared O-RUs UNI $\leq 1100ns$ (For Enhanced RU) + +| | | | | | +|----------------------------|----------------------------------------------------------------------------------------------------------------------------------------|--------------------|--------------------|----------------| +| | b. $\text{Max} TE_L $ measured on Clock Tester at Shared O-RU UNI $\leq 1100ns$ (For Regular RU) | | | | +| | <b><u>Verifications for Maximum Relative Packet Time Error</u></b> | | | | +| | 1. Verify the Maximum Relative Time Error measurements between the Shared O-RUs UNI. | | | | +| | a. $\text{max} TE_{RL} (1,2) \leq 60ns$ (FR2) (For Enhanced RU) | | | | +| | b. $\text{max} TE_{RL} (1,2) \leq 190ns$ (FR1) (For Enhanced RU) | | | | +| | c. $\text{max} TE_{RL} (1,2) \leq 100ns$ (FR1) (For Regular RU) | | | | +| | <b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b> | | | | +| | 1. Verify the 1PPS time error measurements on Clock Tester at Shared O-RUs UNI. | | | | +| | a. Max 1PPS $ TE_L $ measured on Clock Tester at Shared O-RUs UNI $\leq 1100ns$ (For Enhanced RU) | | | | +| | b. Max 1PPS $ TE_L $ measured on Clock Tester at Shared O-RUs UNI $\leq 1100ns$ (For Regular RU) | | | | +| | <b><u>Verifications for Maximum Relative 1PPS Time Error</u></b> | | | | +| | 1. Estimate the Maximum Relative 1PPS Time Error measurements between the Shared O-RUs UNI. | | | | +| | a. $\text{max} 1PPS TE_{RL} (1,2) \leq 60ns$ (FR2) (For Enhanced RU) | | | | +| | b. $\text{max} 1PPS TE_{RL} (1,2) \leq 190ns$ (FR1) (For Enhanced RU) | | | | +| | c. $\text{max} 1PPS TE_{RL} (1,2) \leq 100ns$ (FR1) (For Regular RU) | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit at Shared O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\text{max} TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\text{max} TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | 1PPS $\text{max} TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\text{max} TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | | $\leq 190ns$ (FR1) | | | +| | Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +1 + +## 9.4.2 Timing Solution for Shared O-RU with separate transport. + +| | | | | +|-------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.02 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error, Shared O-RU | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at measurement plane of Shared O-RU UNI. | | | +| <b>Test Description</b> | LLS-C3 configurations for Shared O-RU with common transport.<br>Two Shared O-RUs are connected to two O-DUs via Access TN and O-DU1 and O-DU2 are managed by SRO-1 and SRO-2 respectively. | | | + +| | | +|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | Only SRO-1 has the host privilege. This means SRO-1 additionally act as Shared O-RU host (SOH). | +| <b>Test Objective:</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on O-DUs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock attributes on O-DUs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at Shared O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between the Shared O-RUs UNI.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at Shared O-RU UNI.</li> <li>6. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) between the Shared O-RUs UNI.</li> <li>7. Verify the Time Wander at Shared O-RU UNI.</li> </ol> | +| <b>Pre-Req</b> | <p>O-RU with Shared O-RU Feature (Not shown in the diagram).</p> <p>Shared O-RU UNI is the measurement plane.</p> <p>Both T-GM1 and T-GM2 share a common Timing Source (e.g. GNSS).</p> <p>T-GM1, HSR1, CSR1 and O-DU1 are managed by SRO-1.</p> <p>T-GM2, HSR2 and O-DU2 are managed by SRO-2.</p> <p>SRO-1 has host privilege.</p> <p>Link between HSR1 and HSR2 doesn't use for S-Plane traffic. It is meant to carry only C/U plane traffic should the need arise.</p> <p>O-DU1 is the ACTIVE O-DU managed by SRO-1 and O-DU2 is the STANDBY O-DU managed by SRO-2.</p> <p>When the ACTIVE O-DU fails, the Shared O-RU helps identify the possible connectivity with STANDBY O-DU managed by SRO-2.</p> | +| <b>Test Topology:</b> | <p>Image: Test Topology Diagram: A block diagram showing the test setup. On the left, a GNSS Simulator provides a Frequency Reference to two SROs. SRO-1 (managed by Shared O-RU host) includes T-GM1, SRO-1, and O-DU1. SRO-2 (managed by SRO2) includes T-GM2, SRO-2, and O-DU2. Both SROs are connected to a Shared O-RU UNI. The diagram shows various timing and error metrics like PRTC-A, PRTC-B, ePRTC, and TE. It also shows connections to Clock Testers and a 1PPS out signal. A legend defines SRO as Shared Resource Operator.</p> <p>The test topology above illustrates the placement of two clock testers at the Shared O-RUs UNI connected to a CSR. 1PPS and 10MHz reference from GNSS Simulator connected to the clock reference inputs of the clock tester.</p> | +| <b>Test Configuration</b> | <p>Configure G.8275.1 profile on all devices.</p> <p>Priority2 of T-GM1 < Priority2 of T-GM2.</p> | +| <b>Procedure:</b> | <b>Detailed Test procedure:</b> | + +1. HSR1 uses the T-GM1 as the Primary Clock Source. +2. HSR2 uses the T-GM2 as the Primary Clock Source. +3. CSR1 and O-DU1 are locked to HSR1. +4. O-DU2 is locked to HSR2. + +#### **Verifications for Clock States and Attributes** + +1. Verify the clock lock state on O-DUs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the clock attributes on O-DUs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +#### **Verifications for Maximum Absolute Packet Time Error** + +1. Verify time error measurements using Clock Tester for the PTP flows from CSR at the Shared O-RU UNI. + - a. $\text{Max}|TE_L|$ measured on Clock Tester at the Shared O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\text{Max}|TE_L|$ measured on Clock Tester at the Shared O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative Packet Time Error** + +1. Verify the Maximum Relative Time Error measurements between the Shared O-RUs UNI. + - a. $\text{max}|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\text{max}|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\text{max}|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify the 1PPS time error measurements on Clock Tester at the Shared O-RU UNI. + - a. Max 1PPS $|TE_L|$ measured on Clock Tester at Shared O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. Max 1PPS $|TE_L|$ measured on Clock Tester at Shared O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### **Verifications for Maximum Relative 1PPS Time Error** + +1. Estimate the Maximum Relative 1PPS Time Error measurements between the Shared O-RUs UNI. + - a. $\text{max}|1PPS\text{ }TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\text{max}|1PPS\text{ }TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\text{max}|1PPS\text{ }TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +#### **Pass/Fail Criteria:** + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. + +#### **Test Output** + +| End-to-End Network Limit at Shared O-RU UNI | Expected Value | | Observed Value | +|---------------------------------------------|--------------------|--------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\text{max} TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\text{max} TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| 1PPS $\text{max} TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| 1PPS $\text{max} TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | + +| | | | | | +|--|---------------------------------------|--------------|--------------|--| +| | Frequency Limit<br>(For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | +|--|---------------------------------------|--------------|--------------|--| + +### 9.4.3 Timing Solution Resiliency for Shared O-RU with separate transport + +### (Link Failure on T-GM1) + +| | | | | +|-------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.03 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error, Shared O-RU | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at measurement plane of Shared O-RU UNI. | | | +| <b>Test Description</b> | <p>LLS-C3 configurations for Shared O-RU with separate transport.</p> <p>Two Shared O-RUs are connected to two O-DUs via Access TN and O-DU1 and O-DU2 are managed by SRO-1 and SRO-2 respectively.</p> <p>Only SRO-1 has the host-privilege. This means SRO-1 additionally act as Shared O-RU host (SOH).</p> <p>Link Failure on T-GM1.</p> | | | +| <b>Test Objective</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on O-DUs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock attributes on O-DUs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at Shared O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between the Shared O-RUs UNI.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) between the Shared O-RUs UNI.</li> <li>7. Verify the Time Wander at Shared O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | Testcase 9.4.2 MUST be a PASS. | | | + +#### Test Topology: + +![Test Topology Diagram for Timing Solution Resiliency. The diagram shows two Shared Resource Operators (SRO-1 and SRO-2) connected to two O-DUs (O-DU1 and O-DU2). SRO-1 is managed by the Shared O-RU host, and SRO-2 is managed by SRO-2. Both SROs are connected to a T-GM1 (SRO-1) and a T-GM2 (SRO-2). The diagram includes a GNSS Simulator, Frequency Reference, and a 1PPS Ref+10MHz Ref signal. It also shows the connection to a Clock Tester and the resulting 1PPS out signals. Performance metrics for Enhanced RU (ER2-FR1) and Regular RU (ER1) are listed at the bottom right.](d6392fb104e2e3d102295b5a9be6c50b_img.jpg) + +**Performance Metrics:** + +- For Enhanced RU(FR2-FR1):** + - $Max |TE_L| \le 60\text{-}190ns$ at O-RU UNI + - $Max TAE = 130\text{-}260ns$ + - $Max |1PPS TE_L| \le 1100ns$ at O-RU UNI + - $Max |1PPS TE_{RL}| \le 60\text{-}190ns$ at O-RU UNI +- For Regular RU(FR1):** + - $Max |TE_L| = 100ns$ at O-RU UNI + - $Max TAE = 260ns$ + - $Max |1PPS TE_L| \le 1100ns$ at O-RU UNI + - $Max |1PPS TE_{RL}| \le 100ns$ at O-RU UNI + +Test Topology Diagram for Timing Solution Resiliency. The diagram shows two Shared Resource Operators (SRO-1 and SRO-2) connected to two O-DUs (O-DU1 and O-DU2). SRO-1 is managed by the Shared O-RU host, and SRO-2 is managed by SRO-2. Both SROs are connected to a T-GM1 (SRO-1) and a T-GM2 (SRO-2). The diagram includes a GNSS Simulator, Frequency Reference, and a 1PPS Ref+10MHz Ref signal. It also shows the connection to a Clock Tester and the resulting 1PPS out signals. Performance metrics for Enhanced RU (ER2-FR1) and Regular RU (ER1) are listed at the bottom right. + +| | | | | | +|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------|------------------|----------------| +| | The test topology above illustrates the placement of clock tester at the Shared O-RUs UNI connected to a CSR. 1PPS and 10MHz reference from GNSS Simulator connected to the clock reference inputs of the clock tester. | | | | +| <b>Test Configuration</b> | Fail the Link between T-GM1 and HSR1. | | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>HSR1 moves to phase-holdover.</li> <li>HSR2 uses the T-GM2 as the Primary Clock Source.</li> <li>CSR1 and O-DU1 are locked to HSR2.</li> <li>O-DU2 is locked to HSR2.</li> </ol> <p><b><u>Verifications for Clock State and Attributes</u></b></p> <ol style="list-style-type: none"> <li>Verify the clock lock state on O-DUs, HSRs, CSRs. The lock state should be Phase-aligned.</li> <li>Verify the clock attributes on O-DUs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3.</li> </ol> <p><b><u>Verifications for Maximum Absolute Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify time error measurements using Clock Tester for the PTP flows from CSR at the Shared O-RU UNI. <ol style="list-style-type: none"> <li><math>\text{Max} TE_L </math> measured on Clock Tester at the Shared O-RU UNI <math>\leq 1100ns</math> (For Enhanced RU)</li> <li><math>\text{Max} TE_L </math> measured on Clock Tester at the Shared O-RU UNI <math>\leq 1100ns</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify the Maximum Relative Time Error measurements between the Shared O-RUs UNI. <ol style="list-style-type: none"> <li><math>\text{max} TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li><math>\text{max} TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li><math>\text{max} TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>Verify the 1PPS time error measurements on Clock Tester at Shared O-RU UNI. <ol style="list-style-type: none"> <li>Max 1PPS <math> TE_L </math> measured on Clock Tester at Shared O-RU UNI <math>\leq 1100ns</math> (For Enhanced RU)</li> <li>Max 1PPS <math> TE_L </math> measured on Clock Tester at Shared O-RU UNI <math>\leq 1100ns</math> (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>Estimate the Maximum Relative 1PPS Time Error measurements between the Shared O-RUs UNI. <ol style="list-style-type: none"> <li><math>\text{max} 1PPS TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li><math>\text{max} 1PPS TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li><math>\text{max} 1PPS TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit at Shared O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\text{max} TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | + +| | | | | | +|--|---------------------------------------|-------------------|-------------------|--| +| | Packet max $ TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | 1PPS max $ TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS max $ TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | Frequency Limit<br>(For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +#### 9.4.4 Timing Solution for Shared O-RU with separate transport (Redundant T-GM and HSR). + +| | | | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.04 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error, Shared O-RU | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at measurement plane of Shared O-RU UNI. | | | +| <b>Test Descriptions</b> | <p>LLS-C3 configurations for Shared O-RU with separate transport.</p> <p>Two Shared O-RUs are connected to two O-DUs via Access TN and O-DU1 and O-DU2 are managed by SRO-1 and SRO-2 respectively.</p> <p>Redundancy at T-GM, HSR and Transport connectivity.</p> <p>Both SRO-1 and SRO-2 has the host-privileges. This means both SRO-1 and SRO-2 additionally act as Shared O-RU host (SOH).</p> | | | +| <b>Test Objective</b> | <ol style="list-style-type: none"> <li>Verify the Clock Lock states on O-DUs, HSRs and CSRs.</li> <li>Verify the steady-state clock attributes on O-DUs, HSRs and CSRs.</li> <li>Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at Shared O-RU UNI.</li> <li>Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between the Shared O-RUs UNI.</li> <li>Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at Shared O-RU UNI.</li> <li>Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) between the Shared O-RUs UNI.</li> <li>Verify the Time Wander at Shared O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | <p>O-RU with Shared O-RU Feature (Not shown in the diagram).</p> <p>Shared O-RU UNI is the measurement plane.</p> <p>Both T-GM1 and T-GM2 share a common Timing Source (e.g. GNSS).</p> <p>T-GM1, HSR1, CSR1 and O-DU1 are managed by SRO-1.</p> <p>T-GM2, HSR2, CSR2 and O-DU2 are managed by SRO-2.</p> <p>Both SRO-1 and SRO-2 MUST have host privileges.</p> <p>O-DU1 is the ACTIVE O-DU managed by SRO-1.</p> <p>When the ACTIVE O-DU Fails, the Shared O-RU helps identify the possible connectivity with STANDBY O-DU managed by SRO-2.</p> | | | + +## Test Topology + +![Test Topology Diagram showing the placement of two clock testers at the O-RUs UNI connected to CSRs. The diagram illustrates the connection between a GNSS Simulator, Frequency Reference, and various O-DUs (O-DU1, O-DU2) and SROs (SRO-1, SRO-2). It shows the flow of signals (RF Signal, PRTC-A, PRTC-B, ePRTC) and the management of clock sources (T-GM1, T-GM2, HSR1, HSR2, CSR1, CSR2) by a Shared O-RU host and SROs. The diagram also includes a legend for Primary (blue arrow) and Backup (yellow arrow) connections, and a list of performance metrics for Enhanced RU (FR2-FR1) and Regular RU (FR1).](7137438ef8e467d696f2bfa51e3ed113_img.jpg) + +The diagram illustrates the test topology for clock synchronization. It shows a GNSS Simulator connected to a Frequency Reference, which provides a 1PPS Ref+10MHz Ref signal. This signal is distributed to O-DU1 and O-DU2 via SRO-1 and SRO-2. O-DU1 is connected to SRO-1 (HSR1) and O-DU2 to SRO-2 (HSR2). Both SROs are managed by a Shared O-RU host. The host also manages the clock sources (T-GM1, T-GM2, HSR1, HSR2, CSR1, CSR2) and the clock testers. The clock testers are connected to the CSRs and provide 1PPS out signals. The diagram includes a legend for Primary (blue arrow) and Backup (yellow arrow) connections, and a list of performance metrics for Enhanced RU (FR2-FR1) and Regular RU (FR1). + +For Enhanced RU (FR2-FR1) + $\text{Max } |TE_{RL}| = 60-190\text{ns}$ at O-RU UNI + $\text{Max } TAE = 130-260\text{ns}$ + $\text{Max } |1PPS TE_L| \leq 1100\text{ns}$ at O-RU UNI + $\text{Max } |1PPS TE_{RL}| \leq 60-190\text{ns}$ at O-RU UNI + +For Regular RU (FR1) + $\text{Max } |TE_{RL}| = 100\text{ns}$ at O-RU UNI + $\text{Max } TAE = 260\text{ns}$ + $\text{Max } |1PPS TE_L| \leq 1100\text{ns}$ at O-RU UNI + $\text{Max } |1PPS TE_{RL}| \leq 100\text{ns}$ at O-RU UNI + +Test Topology Diagram showing the placement of two clock testers at the O-RUs UNI connected to CSRs. The diagram illustrates the connection between a GNSS Simulator, Frequency Reference, and various O-DUs (O-DU1, O-DU2) and SROs (SRO-1, SRO-2). It shows the flow of signals (RF Signal, PRTC-A, PRTC-B, ePRTC) and the management of clock sources (T-GM1, T-GM2, HSR1, HSR2, CSR1, CSR2) by a Shared O-RU host and SROs. The diagram also includes a legend for Primary (blue arrow) and Backup (yellow arrow) connections, and a list of performance metrics for Enhanced RU (FR2-FR1) and Regular RU (FR1). + +The test topology above illustrates the placement of two clock testers at the O-RUs UNI connected to CSRs. 1PPS and 10MHz reference from GNSS Simulator connected to the clock reference inputs of the clock tester. + +## Test Configuration + +Configure G.8275.1 profile on all devices. +Priority2 of T-GM1 < Priority2 of T-GM2. + +## Procedure + +### Detailed Test procedure: + +- HSR1 uses T-GM1 as the Primary Clock Source. +- HSR2 uses T-GM2 as the Primary Clock Source. +- CSR1 & CSR2 run A-BTCA, and both select clock from HSR1. +- O-DU1 locked to HSR1. +- O-DU2 locked to HSR2. + +### Verifications for Clock States and Attributes + +- Verify the clock lock state on O-DUs, HSRs, CSRs. The lock state should be Phase-aligned. +- Verify the clock attributes on O-DUs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +### Verifications for Maximum Absolute Packet Time Error + +- Verify time error measurements using Clock Tester for the PTP flows from CSR at the Shared O-RU UNI. + - $\text{Max } |TE_L|$ measured on Clock Tester at the Shared O-RU UNI $\leq 1100\text{ns}$ (For Enhanced RU) + - $\text{Max } |TE_L|$ measured on Clock Tester at the Shared O-RU UNI $\leq 1100\text{ns}$ (For Regular RU) + +### Verifications for Maximum Relative Packet Time Error + +- Verify the Maximum Relative Time Error measurements between the Shared O-RUs UNI. + - $\text{max } |TE_{RL}| (1,2) \leq 60\text{ns}$ (FR2) (For Enhanced RU) + - $\text{max } |TE_{RL}| (1,2) \leq 190\text{ns}$ (FR1) (For Enhanced RU) + - $\text{max } |TE_{RL}| (1,2) \leq 100\text{ns}$ (FR1) (For Regular RU) + +### Verifications for Maximum Absolute 1PPS Time Error + +| | | | | | +|---------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------|-------------------|----------------| +| | 1. Verify the 1PPS time error measurements on Clock Tester at Shared O-RU UNI.<br>a. Max 1PPS $ TE_L $ measured on Clock Tester at Shared O-RU UNI $\leq 1100ns$ (For Enhanced RU)<br>b. Max 1PPS $ TE_L $ measured on Clock Tester at Shared O-RU UNI $\leq 1100ns$ (For Regular RU) | | | | +| | <b>Verifications for Maximum Relative 1PPS Time Error</b><br>1. Estimate the Maximum Relative 1PPS Time Error measurements between the Shared O-RUs UNI.<br>a. $\max 1PPS\ TE_{RL} (1,2) \leq 60ns$ (FR2) (For Enhanced RU)<br>b. $\max 1PPS\ TE_{RL} (1,2) \leq 190ns$ (FR1) (For Enhanced RU)<br>c. $\max 1PPS\ TE_{RL} (1,2) \leq 100ns$ (FR1) (For Regular RU) | | | | +| <b>Pass/Fail Criteria</b> | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit at Shared O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | 1PPS $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | 1PPS $\max TE_{RL} $ | $\leq 60ns(FR2)$ | $\leq 100ns(FR1)$ | | +| | | $\leq 190ns(FR1)$ | | | +| | Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +## 9.4.5 Timing Solution Resiliency for Shared O-RU with separate transport (Link Failure on HSR1) + +| | | | | +|--------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.05 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error, Shared O-RU | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at measurement plane of O-RU UNI. | | | +| <b>Test Descriptions</b> | LLS-C3 configurations for Shared O-RU with separate transport.<br>Two Shared O-RUs are connected to two O-DUs via Access TN and O-DU1 and O-DU2 are managed by SRO-1 and SRO-2 respectively.<br>Redundancy at T-GM, HSR and Transport connectivity.<br>Both SRO-1 and SRO-2 have the host privileges. This means both SRO-1 and SRO-2 additionally act as Shared O-RU host (SOH).<br>Link Failure on HSR1. | | | +| <b>Test Objective</b> | 1. Verify the Clock Lock states on O-DUs, HSRs and CSRs.<br>2. Verify the steady-state clock attributes on O-DUs, HSRs and CSRs.<br>3. Verify the Maximum Absolute Packet Time Error ( $\max TE_L $ ) at Shared O-RU UNI. | | | + +4. Verify the Maximum Relative Packet Time Error ( $Max|TE_{RL}|$ ) at the Shared O-RUs UNI ports. +5. Verify the Maximum Absolute 1PPS Time Error ( $Max|TE_L|$ ) at Shared O-RU UNI. +6. Verify the Maximum Relative 1PPS Time Error ( $Max|TE_{RL}|$ ) at Shared O-RU UNI. +7. Verify the Time Wander at Shared O-RU UNI. + +### Pre-Req + +Testcase 9.4.4 MUST be a PASS. + +### Test Topology + +![Test Topology Diagram showing the connection between O-DU UNI, SROs, T-GMs, CSRs, and Clock Testers. The diagram illustrates the flow of signals and the management of clock sources. Key components include O-DU UNI, SRO-1, SRO-2, T-GM1, T-GM2, CSRs, and Clock Testers. The diagram also shows the connection to a GNSS Simulator and a Frequency Reference. The diagram is divided into two main sections: 'managed by Shared O-RU host' and 'managed by SRO2'. The diagram includes various labels for signals and time errors, such as PRTC-A, PRTC-B, ePRTC, and T-BC/EEC/eEEC. The diagram also includes a legend for Primary and Backup signals, and a note about the SRO: Shared Resource Operator.](b016ec57d20d073d4cba849c140ae5cb_img.jpg) + +The diagram illustrates the test topology for clock synchronization. It shows two Shared Resource Operators (SROs) connected to O-DU UNI. SRO-1 is connected to T-GM1 and SRO-2 is connected to T-GM2. Both SROs are connected to CSRs (Clock Source Registers). The CSRs are connected to Clock Testers. The diagram also shows the connection to a GNSS Simulator and a Frequency Reference. The diagram is divided into two main sections: 'managed by Shared O-RU host' and 'managed by SRO2'. The diagram includes various labels for signals and time errors, such as PRTC-A, PRTC-B, ePRTC, and T-BC/EEC/eEEC. The diagram also includes a legend for Primary and Backup signals, and a note about the SRO: Shared Resource Operator. + +Test Topology Diagram showing the connection between O-DU UNI, SROs, T-GMs, CSRs, and Clock Testers. The diagram illustrates the flow of signals and the management of clock sources. Key components include O-DU UNI, SRO-1, SRO-2, T-GM1, T-GM2, CSRs, and Clock Testers. The diagram also shows the connection to a GNSS Simulator and a Frequency Reference. The diagram is divided into two main sections: 'managed by Shared O-RU host' and 'managed by SRO2'. The diagram includes various labels for signals and time errors, such as PRTC-A, PRTC-B, ePRTC, and T-BC/EEC/eEEC. The diagram also includes a legend for Primary and Backup signals, and a note about the SRO: Shared Resource Operator. + +The test topology above illustrates the placement of two clock testers at the Shared O-RUs UNI connected to CSRs. 1PPS and 10MHz reference from GNSS Simulator connected to the clock reference inputs of the clock tester. + +### Test Configuration + +Fail the links between HSR1 and CSRs. + +### Procedure: + +#### Detailed Test procedure: + +1. HSR1 uses the T-GM1 as the Primary Clock Source. +2. HSR2 uses the T-GM2 as the Primary Clock Source. +3. CSR1 & CSR2 both select clock from HSR2. +4. O-DU1 locked to HSR1. +5. O-DU2 locked to HSR2. + +#### Verifications for Clock States and Attributes + +1. Verify the clock lock state on O-DUs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the clock attributes on O-DUs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +#### Verifications for Maximum Absolute Packet Time Error + +1. Verify time error measurements using Clock Tester for the PTP flows from CSR at the Shared O-RU UNI. + - a. $Max|TE_L|$ measured on Clock Tester at Shared O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $Max|TE_L|$ measured on Clock Tester at Shared O-RU UNI $\leq 1100ns$ (For Regular RU) + +#### Verifications for Maximum Relative Packet Time Error + +| | | | | | +|--|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------|------------------------------------------------------|--------------------| +| | 1. Verify the Maximum Relative Time Error measurements between the Shared O-RUs UNI. <ol style="list-style-type: none"> <li><math>\max TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li><math>\max TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> <b>Verifications for Maximum Absolute 1PPS Time Error</b> <ol style="list-style-type: none"> <li>Verify the 1PPS time error measurements on Clock Tester at Shared O-RU UNI. <ol style="list-style-type: none"> <li>Max 1PPS <math> TE_L </math> measured on Clock Tester at Shared O-RU UNI <math>\leq 1100ns</math> (For Enhanced RU)</li> <li>Max 1PPS <math> TE_L </math> measured on Clock Tester at Shared O-RU UNI <math>\leq 1100ns</math> (For Regular RU)</li> </ol> <b>Verifications for Maximum Relative 1PPS Time Error</b> <ol style="list-style-type: none"> <li>Estimate the Maximum Relative 1PPS Time Error measurements between the Shared O-RUs UNI. <ol style="list-style-type: none"> <li><math>\max 1PPS TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li><math>\max 1PPS TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li><math>\max 1PPS TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> </li> </ol> | | | | +| | <b>Pass/Fail Criteria:</b> Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | +| | <b>Test Output</b> | End-to-End Network Limit at Shared O-RU UNI | Expected Value<br>(For Enhanced RU) (For Regular RU) | Observed Value | +| | | Packet $\max TE_L $ | $\leq 1100ns$ $\leq 1100ns$ | | +| | | Packet $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | +| | | | $\leq 190ns$ (FR1) | | +| | | 1PPS $\max TE_L $ | $\leq 1100ns$ $\leq 1100ns$ | | +| | | 1PPS $\max TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | +| | | | $\leq 190ns$ (FR1) | | +| | | Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ $\leq 32ppb$ | | + +## 9.4.6 Timing Solution for Shared O-RU with separate transport (Full Redundancy) + +| | | | | +|-------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.06 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error, Shared O-RU | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at measurement plane of O-RU UNI. | | | +| <b>Test Description</b> | LLS-C3 configurations for Shared O-RU with separate transport.<br>Two Shared O-RUs are connected to two O-DUs via Access TN and O-DU1 and O-DU2 are managed by SRO-1 and SRO-2 respectively.<br>Full Redundancy in Access Transport Network.<br>Both SRO-1 and SRO-2 have the host privileges. This means both SRO-1 and SRO-2 additionally act as Shared O-RU host (SOH). | | | + +| | | +|---------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Objective</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on O-DUs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock attributes on O-DUs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at Shared O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between the Shared O-RUs UNI.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at Shared O-RU UNI.</li> <li>6. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) between the Shared O-RUs UNI.</li> <li>7. Verify the Time Wander at Shared O-RU UNI.</li> </ol> | +| <b>Pre-Req</b> | <p>O-RU with Shared O-RU Feature (Not shown in the diagram).</p> <p>Shared O-RU UNI is the measurement plane.</p> <p>Both T-GM1 and T-GM2 share a common Timing Source (e.g. GNSS).</p> <p>T-GM1A, T-GM1B, HSR1A, HSR1B, CSR1 and O-DU1 are managed by SRO-1.</p> <p>T-GM2A, T-GM2B, HSR2A, HSR2B, CSR2 and O-DU2 are managed by SRO-2.</p> <p>Both SRO-1 and SRO-2 MUST have host privileges.</p> <p>O-DU1 is the ACTIVE O-DU managed by SRO-1.</p> <p>When the ACTIVE O-DU Fails, the Shared O-RU helps identify the possible connectivity with STANDBY O-DU managed by SRO-2.</p> | +| <b>Test Topology</b> | <p>Image: Test Topology Diagram showing two Shared Resource Operators (SRO-1 and SRO-2) managing multiple O-DUs and HSRs. SRO-1 manages O-DU1, T-GM1A, T-GM1B, HSR1A, and HSR1B. SRO-2 manages O-DU2, T-GM2A, T-GM2B, HSR2A, and HSR2B. A GNSS Simulator provides a Frequency Reference and RF Signal to both SROs. The diagram shows connections to a Shared O-RU UNI with two Clock Testers. Performance metrics for Enhanced RU (FR2-FR1) and Regular RU (FR1) are listed.</p> <p>The test topology above illustrates the placement of two clock tester at the Shared O-RUs UNI connected to CSRs. 1PPS and 10MHz reference from GNSS Simulator connected to the clock reference inputs of the clock tester.</p> <p>For Enhanced RU (FR2-FR1)<br/> <math>Max TE_{RL} = 60-190ns</math> at O-RU UNI<br/> <math>Max TA_E = 130-260ns</math><br/> <math>Max 1PPS TE_L \leq 1100ns</math> at O-RU UNI<br/> <math>Max 1PPS TE_{RL} \leq 60-190ns</math> at O-RU UNI</p> <p>For Regular RU (FR1)<br/> <math>Max TE_{RL} = 100ns</math> at O-RU UNI<br/> <math>Max TA_E = 360ns</math><br/> <math>Max 1PPS TE_L \leq 1100ns</math> at O-RU UNI<br/> <math>Max 1PPS TE_{RL} \leq 100ns</math> at O-RU UNI</p> | +| <b>Test Configuration</b> | <p>Configure G.8275.1 profile on all devices.</p> <p>Configure Priority2 of T-GM1 < Priority2 of T-GM2.</p> | +| <b>Procedure</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. HSR1A and HSR1B uses the T-GM1A as the Primary Clock Source.</li> <li>2. HSR2A and HSR2B uses the T-GM2A as the Primary Clock Source.</li> <li>3. CSR1 & CSR2 run A-BTCA, and both select clock from HSR1.</li> <li>4. O-DU1 locked to HSR1A.</li> </ol> | + +## 5. O-DU2 locked to HSR2A. + +**Verifications for Clock State and Attributes** + +1. Verify the clock lock state on O-DUs, HSRs, CSRs. The lock state should be Phase-aligned. +2. Verify the clock attributes on O-DUs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3. + +**Verifications for Maximum Absolute Packet Time Error** + +1. Verify time error measurements using Clock Tester for the PTP flows from CSR at the Shared O-RU UNI. + - a. $\text{Max}|TE_L|$ measured on Clock Tester at the Shared O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. $\text{Max}|TE_L|$ measured on Clock Tester at the Shared O-RU UNI $\leq 1100ns$ (For Regular RU) + +**Verifications for Maximum Relative Packet Time Error** + +1. Verify the Maximum Relative Time Error measurements between the Shared O-RUs UNI. + - a. $\text{max}|TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\text{max}|TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\text{max}|TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +**Verifications for Maximum Absolute 1PPS Time Error** + +1. Verify the 1PPS time error measurements on Clock Tester at Shared O-RU UNI. + - a. Max 1PPS $|TE_L|$ measured on Clock Tester at Shared O-RU UNI $\leq 1100ns$ (For Enhanced RU) + - b. Max 1PPS $|TE_L|$ measured on Clock Tester at Shared O-RU UNI $\leq 1100ns$ (For Regular RU) + +**Verifications for Maximum Relative 1PPS Time Error** + +1. Estimate the Maximum Relative 1PPS Time Error measurements between the Shared O-RUs UNI. + - a. $\text{max}|1PPS TE_{RL}|(1,2) \leq 60ns$ (FR2) (For Enhanced RU) + - b. $\text{max}|1PPS TE_{RL}|(1,2) \leq 190ns$ (FR1) (For Enhanced RU) + - c. $\text{max}|1PPS TE_{RL}|(1,2) \leq 100ns$ (FR1) (For Regular RU) + +**Pass/Fail Criteria:** + +Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. + +**Test Output** + +| End-to-End Network Limit at Shared O-RU UNI | Expected Value | | Observed Value | +|---------------------------------------------|--------------------|--------------------|----------------| +| | (For Enhanced RU) | (For Regular RU) | | +| Packet $\text{max} TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| Packet $\text{max} TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| 1PPS $\text{max} TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| 1PPS $\text{max} TE_{RL} $ | $\leq 60ns$ (FR2) | $\leq 100ns$ (FR1) | | +| | $\leq 190ns$ (FR1) | | | +| Frequency Limit (For PRTC Class-A) | $\leq 32ppb$ | $\leq 32ppb$ | | + +## 9.4.7 Timing Solution Resiliency for Shared O-RU with separate transport (GM1A and HSR1A Failure) + +| | | | | +|-------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|-------------------------------------------------------------------------------------| +| <b>Test ID</b> | SYNC.TE.07 | <b>Classification</b> | Synchronization, Performance, Absolute Time Error, Relative Time Error, Shared O-RU | +| <b>Test Title</b> | Measurement of Absolute Time Error, Relative Time Error at measurement plane of O-RU UNI. | | | +| <b>Test Description</b> | <p>LLS-C3 configurations for Shared O-RU with separate transport.</p> <p>Two Shared O-RUs are connected to two O-DUs via Access TN and O-DU1 and O-DU2 are managed by SRO-1 and SRO-2 respectively.</p> <p>Full Redundancy in Access Transport Network.</p> <p>Both SRO-1 and SRO-2 have the host privileges. This means both SRO-1 and SRO-2 additionally act as Shared O-RU host (SOH).</p> <p>Link Failure on T-GM1A and HSR1A.</p> | | | +| <b>Test Objective</b> | <ol style="list-style-type: none"> <li>1. Verify the Clock Lock states on O-DUs, HSRs and CSRs.</li> <li>2. Verify the steady-state clock attributes on O-DUs, HSRs and CSRs.</li> <li>3. Verify the Maximum Absolute Packet Time Error (<math>Max TE_L </math>) at Shared O-RU UNI.</li> <li>4. Verify the Maximum Relative Packet Time Error (<math>Max TE_{RL} </math>) between the Shared O-RUs UNI.</li> <li>5. Verify the Maximum Absolute 1PPS Time Error (<math>Max TE_L </math>) at O-RU UNI.</li> <li>6. Verify the Maximum Relative 1PPS Time Error (<math>Max TE_{RL} </math>) between the Shared O-RUs UNI.</li> <li>7. Verify the Time Wander at Shared O-RU UNI.</li> </ol> | | | +| <b>Pre-Req</b> | Testcase 9.4.6 MUST be a PASS. | | | + +![Test Topology Diagram for Timing Solution Resiliency. The diagram shows a network setup with two Shared Resource Operators (SRO-1 and SRO-2) and their associated O-DUs, HSRs, and CSRs. SRO-1 manages SRO-1 (O-DU1, T-TSC/EEC/EEC) and SRO-1 (HSR1B, T-BC/EEC/EEC). SRO-2 manages SRO-2 (O-DU2, T-TSC/EEC/EEC) and SRO-2 (HSR2B, T-BC/EEC/EEC). A GNSS Simulator provides a 1PPS Ref+10MHz Ref signal to the CSRs. The diagram also shows the connection to a Shared O-RU UNI and the placement of two clock testers. Performance metrics for Enhanced RU (FR2-FR1) and Regular RU (FR1) are listed.](77f037e0a627c6188175167f6dd84148_img.jpg) + +**Test Topology** + +The test topology above illustrates the placement of two clock testers at the Shared O-RUs UNI connected to CSRs. 1PPS and 10MHz reference from GNSS Simulator connected to the clock reference inputs of the clock tester. + +For Enhanced RU (FR2-FR1) + $Max|TE_{RL}| = 60-190ns$ at O-RU UNI + $Max TAE = 130-260ns$ + $Max|1PPS TE_L| \leq 1100ns$ at O-RU UNI + $Max|1PPS TE_{RL}| \leq 60-190ns$ at O-RU UNI + +For Regular RU (FR1) + $Max|TE_{RL}| = 100ns$ at O-RU UNI + $Max TAE = 260ns$ + $Max|1PPS TE_L| \leq 1100ns$ at O-RU UNI + $Max|1PPS TE_{RL}| \leq 100ns$ at O-RU UNI + +Test Topology Diagram for Timing Solution Resiliency. The diagram shows a network setup with two Shared Resource Operators (SRO-1 and SRO-2) and their associated O-DUs, HSRs, and CSRs. SRO-1 manages SRO-1 (O-DU1, T-TSC/EEC/EEC) and SRO-1 (HSR1B, T-BC/EEC/EEC). SRO-2 manages SRO-2 (O-DU2, T-TSC/EEC/EEC) and SRO-2 (HSR2B, T-BC/EEC/EEC). A GNSS Simulator provides a 1PPS Ref+10MHz Ref signal to the CSRs. The diagram also shows the connection to a Shared O-RU UNI and the placement of two clock testers. Performance metrics for Enhanced RU (FR2-FR1) and Regular RU (FR1) are listed. + +| | | | | | +|----------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------|--------------------|----------------| +| <b>Test Configuration</b> | Fail the HSR1A and T-GM1A. | | | | +| <b>Procedure</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. HSR1B uses the T-GM1B as the Primary Clock Source.</li> <li>2. HSR2A and HSR2B uses the T-GM2A as the Primary Clock Source.</li> <li>3. CSR1 & CSR2 run A-BTCA, and both select clock from HSR1B.</li> <li>4. O-DU1 is locked to HSR1B.</li> <li>5. O-DU2 is locked to HSR2A.</li> </ol> <p><b><u>Verifications for Clock States and Attributes</u></b></p> <ol style="list-style-type: none"> <li>1. Verify the clock lock state on O-DUs, HSRs, CSRs. The lock state should be Phase-aligned.</li> <li>2. Verify the clock attributes on O-DUs, HSRs and CSRs as per ITU-T G.8275.1 Standard-Appendix V, Table V.3.</li> </ol> <p><b><u>Verifications for Maximum Absolute Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify time error measurements using Clock Tester for the PTP flows from CSR at the Shared O-RU UNI. <ol style="list-style-type: none"> <li>a. <math>\text{Max} TE_L </math> measured on Clock Tester at the Shared O-RU UNI <math>\leq 1100ns</math><br/>(For Enhanced RU)</li> <li>b. <math>\text{Max} TE_L </math> measured on Clock Tester at the Shared O-RU UNI <math>\leq 1100ns</math><br/>(For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative Packet Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify the Maximum Relative Time Error measurements between the Shared O-RUs UNI. <ol style="list-style-type: none"> <li>a. <math>\max TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li>b. <math>\max TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li>c. <math>\max TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Absolute 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Verify the 1PPS time error measurements on Clock Tester at Shared O-RU UNI. <ol style="list-style-type: none"> <li>a. Max 1PPS <math> TE_L </math> measured on Clock Tester at Shared O-RU UNI <math>\leq 1100ns</math><br/>(For Enhanced RU)</li> <li>b. Max 1PPS <math> TE_L </math> measured on Clock Tester at Shared O-RU UNI <math>\leq 1100ns</math><br/>(For Regular RU)</li> </ol> </li> </ol> <p><b><u>Verifications for Maximum Relative 1PPS Time Error</u></b></p> <ol style="list-style-type: none"> <li>1. Estimate the Maximum Relative 1PPS Time Error measurements between the Shared O-RUs UNI. <ol style="list-style-type: none"> <li>a. <math>\max 1\text{PPS } TE_{RL} (1,2) \leq 60ns</math> (FR2) (For Enhanced RU)</li> <li>b. <math>\max 1\text{PPS } TE_{RL} (1,2) \leq 190ns</math> (FR1) (For Enhanced RU)</li> <li>c. <math>\max 1\text{PPS } TE_{RL} (1,2) \leq 100ns</math> (FR1) (For Regular RU)</li> </ol> </li> </ol> | | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the Maximum absolute TE, Maximum Relative TE and Time Wander Limit measurement result is below the limit specified. | | | | +| <b>Test Output</b> | End-to-End Network Limit at Shared O-RU UNI | Expected Value | | Observed Value | +| | | (For Enhanced RU) | (For Regular RU) | | +| | Packet $\max TE_L $ | $\leq 1100ns$ | $\leq 1100ns$ | | +| | Packet $\max TE_{RL} $ | $\leq 60ns (FR2)$ | $\leq 100ns (FR1)$ | | +| | | $\leq 190ns (FR1)$ | | | + +| | | | | | +|--|---------------------------------------|--------------|--------------|--| +| | 1PPS max TE <sub>L</sub> | ≤ 1100ns | ≤ 1100ns | | +| | 1PPS max TE <sub>RL</sub> | ≤ 60ns(FR2) | ≤ 100ns(FR1) | | +| | | ≤ 190ns(FR1) | | | +| | Frequency Limit<br>(For PRTC Class-A) | ≤ 32ppb | ≤ 32ppb | | + +1 +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 +16 +17 +18 +19 + +# Annex A: ITU G.8262/G.8262.1 Clock specification test cases for TNEs + +SyncE performance as per G.8262/G.8262.1 clock specifications + +## A.1 Pull-in/Hold-in/Pull-out Limits + +| | | | | +|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|------------------------------| +| <b>Test ID</b> | SYNC.SE.01 | <b>Classification</b> | Synchronization, Performance | +| <b>Test Title</b> | Pull-in/hold-in/pull-out limits on HSR/CSR | | | +| <b>Test Objective:</b> | Verify the Pull-in/hold-in/pull-out range meets ITU-T G.8262/G.8262.1 | | | +| <b>Pre-Req</b> | HSR/CSR connected to a tester which uses a stable reference clock | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A GNSS satellite icon points to a 'Reference' box. The 'Reference' box points to a 'Clock Tester' box. The 'Clock Tester' box is connected to an 'HSR/CSR' box via 'Link1' and 'Link2'. The 'HSR/CSR' box contains 'EEC/eEEC'. Double-headed arrows labeled 'QL-PRC/ePRC' connect the 'Clock Tester' to the 'HSR/CSR' box on both links." data-bbox="430 848 1386 1240" src="b1da9df21a4d28b51bccbfa46c00916e_img.jpg"/> | | | +| <b>Test Configuration</b> | <p>To measure the ‘pull-in’ range, apply a high frequency offset to the selected clock input using clock tester so that the device will enter into holdover mode. Now reduce the offset in arbitrary small step until EEC/eEEC locks to the input source. EEC/eEEC should lock to the input source before the offset reaches to <math>\pm 4.6</math>PPM.</p> <p>To measure the ‘hold-in’ range, vary the frequency offset arbitrarily, slowly, and measure the highest frequency offset within which the device maintains lock.</p> <p>‘Pull-out’ range is the offset within which the device stays in locked state and outside of which the device loses the lock irrespective of the rate of the frequency change.</p> | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect the tester to HSR/CSR fronthaul interface.</li> <li>2. Configure tester to provide the clock to DUT configured interface.</li> <li>3. Establish Frequency Synchronization on DUT.</li> <li>4. Inject PPM offset from the tester as per the ITU-T G.8262/G.8262.1</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Verify that SyncE and ESMC/eESMC are up.</li> <li>2. Perform the Pull-in/hold-in/Pull-out test on the device under test.</li> <li>3. Compare the test result as per ITU-T G.8262/G.8262.1</li> </ol> | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the measurement result is below the limit specified by ITU-T G.8262/ G.8262.1 clock specifications. | | | +| <b>Test Output</b> | ITU-T G.8262/G.8262.1 defined the limit of $\pm 4.6$ PPM | | | + +## A.2 Wander Generation Limit for EEC/eEEC Clock + +| | | | | +|----------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|-------------------------------| +| <b>Test ID</b> | SYNC.SE.02 | <b>Classification</b> | Synchronization, Performance, | +| <b>Test Title</b> | Frequency Error/TIE/MTIE/TDEV on HSR/CSR | | | +| <b>Test Objective:</b> | Verify the device maximum output wander or TIE/MTIE/TDEV | | | +| <b>Pre-Req</b> | HSR/CSR connected to a tester which uses a stable reference clock.<br>TNE should support ESMC or eESMC as applicable. | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A GNSS antenna is connected to a Reference block. The Reference block is connected to a Clock Tester block. The Clock Tester block is connected to two links, Link1 and Link2, which both connect to a device block. The device block contains HSR/CSR and EEC/eEEC sections. The links are labeled QL-PRC/ePRC." data-bbox="430 672 1388 1064" src="3f557f4f67b894c2036734bf5b77af72_img.jpg"/> | | | +| <b>Test Configuration</b> | This section to be filled out when putting the test report (may include device and/or tester configuration) | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect the tester to HSR/CSR interface.</li> <li>2. Configure tester to provide the clock to DUT configured interface.</li> <li>3. Establish Frequency Synchronization on DUT.</li> <li>4. Perform the wander generation test.</li> </ol> <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Verify that SyncE and ESMC/eESMC are up.</li> <li>2. Verify the Frequency Error/TIE/MTIE/TDEV <ol style="list-style-type: none"> <li>a. All the results should be within ITU-T G.8262/G.8262.1 clock specification limits</li> </ol> </li> </ol> | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the measurement result is below the limit specified by ITU-T G.8262/G.8262.1 clock specifications. | | | +| <b>Test Output</b> | This section is the placeholder that will capture the output/configurations after test is executed, typically done after test execution | | | + +## A.3 Wander Tolerance/Transfer Test for EEC/eEEC Clock + +| | | | | +|-------------------|--------------------------------------------|-----------------------|------------------------------| +| <b>Test ID</b> | SYNC.SE.03 | <b>Classification</b> | Synchronization, Performance | +| <b>Test Title</b> | Wander Tolerance/Wander Transfer @ HSR/CSR | | | + +| | | +|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Objective:</b> | Verify the device wander tolerance and wander transfer performance | +| <b>Pre-Req</b> | <p>HSR/CSR connected to a tester which uses a stable reference clock.</p> <p>TNE should support ESMC or eESMC as applicable.</p> <p>Stimulus for input wander noise to be enabled in the tester.</p> | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A GNSS satellite icon points to a 'Reference' box. The 'Reference' box points to a 'Clock Tester' box. The 'Clock Tester' box is connected to a device box via two links, 'Link1' and 'Link2'. The device box contains 'HSR/CSR' and 'EEC/eEEC' sections. Above Link1 and below Link2 are labels 'QL-PRC/ePRC' with double-headed arrows." data-bbox="430 459 1380 851" src="7c774c70315893c49a2e5393b9c46165_img.jpg"/> | +| <b>Test Configuration</b> | This section to be filled out when putting the test report (may include device and/or tester configuration) | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect the tester to HSR/CSR fronthaul interface.</li> <li>2. Configure tester to provide the clock to DUT configured interface.</li> <li>3. Establish Frequency Synchronization on DUT.</li> <li>4. Perform the wander tolerance/wander transfer test by adding wander noises as input stimulus to the device under test.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that SyncE and ESMC/eESMC are up.</li> <li>2. Device shouldn't lose lock/no alarm/no reference switch-over with the input wander.</li> <li>3. Criteria for wander tolerance test as per G.8262/G.8262.1 EEC/eEEC specification. <ol style="list-style-type: none"> <li>a. Device should maintain the performance within limits.</li> <li>b. Device shouldn't lose lock/no alarm/no reference switch-over with the input wander.</li> <li>c. Device shouldn't move to holdover state.</li> </ol> </li> <li>4. Verify the wander transfer characteristics. <ol style="list-style-type: none"> <li>a. Wander transfer characteristics should conform ITU G.8262/G.8262.1 EEC/eEEC limits.</li> <li>b. In the passband (1Hz-3Hz), the phase gain of the eEEC should be smaller than 0.2dB.</li> </ol> </li> <li>5. Compare the test result as per ITU-T G.8262/G.8262.1 clock specifications.</li> </ol> | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the measurement result is below the limit specified by ITU-T G.8262/G.8262.1 clock specifications. | +| <b>Test Output:</b> | This section is the placeholder that will capture the output/configurations after test is executed, typically done after test execution | + +## A.4 Frequency Holdover Limits for EEC/eEEC Clock + +| | | | | +|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|-------------------------------| +| <b>Test ID</b> | SYNC.SE.04 | <b>Classification</b> | Synchronization, Performance, | +| <b>Test Title</b> | Frequency holdover limits on HSR/CSR | | | +| <b>Test Objective:</b> | Verify the device maximum wander or TIE/MTIE/TDEV in the Frequency holdover state. | | | +| <b>Pre-Req</b> | HSR/CSR connected to a tester which uses a stable reference clock.<br>TNE should support ESMC or eESMC as applicable. | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A GNSS satellite icon points to a 'Reference' box. The 'Reference' box points to a 'Clock Tester' box. The 'Clock Tester' box is connected to a 'Holdover Mode' box via two links: 'Link1' and 'Link2'. Both links are labeled 'QL-PRC/ePRC'. A red 'X' is placed over the connection between the 'Clock Tester' and the 'Holdover Mode' box. The 'Holdover Mode' box contains 'HSR/CSR' and 'EEC/eEEC' components." data-bbox="430 705 1388 1097" src="47cbca4aa302f4f5ae38673c651e1d36_img.jpg"/> | | | +| <b>Test Configuration</b> | This section to be filled out when putting the test report (may include device and/or tester configuration) | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect the tester to HSR/CSR fronthaul interface.</li> <li>2. Configure tester to provide the clock to DUT configured interface.</li> <li>3. Establish Frequency Synchronization on DUT.</li> <li>4. Perform the wander generation test for 15 min.</li> <li>5. Break the Link1 or stops ESMC/eESMC transmission on Link1.</li> <li>6. Perform the wander generation test for 24 hrs.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that SyncE and ESMC/eESMC are up.</li> <li>2. Device should be Frequency synchronized to tester via Link1.</li> <li>3. Verify the Frequency Error/TIE/MTIE/TDEV before breaking the link. <ol style="list-style-type: none"> <li>a. All the results should be within ITU-T G.8262/G.8262.1 specification limits.</li> </ol> </li> <li>4. Continue verify the Frequency Error/TIE/MTIE/TDEV after breaking the link. <ol style="list-style-type: none"> <li>a. All the results should be within ITU-T G.8262/G.8262.1 holdover specification limits</li> </ol> </li> </ol> | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the measurement result is below the limit specified by ITU-T G.8262/G.8262.1 clock specifications. | | | +| <b>Test Output</b> | This section is the placeholder that will capture the output/configurations after test is executed, typically done after test execution | | | + +## A.5 Short-term phase-transients as per ITU-T G.8262/G.8262.1 + +| | | | | +|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|----------------------------------------| +| <b>Test ID</b> | SYNC.SE.05 | <b>Classification</b> | Synchronization, Performance, TIE/MTIE | +| <b>Test Title</b> | Failover performance or Short-term phase-transients | | | +| <b>Test Objective:</b> | Verify the TIE/MTIE during the failure of primary reference for a short duration (<15 sec) | | | +| <b>Pre-Req</b> | HSR/CSR connected to a tester which uses a stable reference clock | | | +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A GNSS satellite icon points to a 'Reference' box. The 'Reference' box points to a 'Clock Tester' box. The 'Clock Tester' box is connected to an 'HSR/CSR' box via two links: 'Link1' (labeled 'QL-PRC/ePRC') and 'Link2' (labeled 'QL-PRC/ePRC'). The 'HSR/CSR' box contains 'EEC/eEEC'. A red lightning bolt labeled 'Interruption in QL' points to the 'QL-PRC/ePRC' label on Link1." data-bbox="438 705 1396 1108" src="0c52b03c91109a1a63a3bb0016116bc4_img.jpg"/> | | | +| <b>Test Configuration</b> | This section to be filled out when putting the test report (may include device and/or tester configuration) | | | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect the tester to HSR/CSR fronthaul interface as per the Topology.</li> <li>2. Configure tester to provide the clock to DUT configured primary interface.</li> <li>3. Establish Frequency Synchronization on DUT.</li> <li>4. Perform the wander generation test.</li> <li>5. Stop the ESMC/eESMC from tester for up to 15 sec.</li> <li>6. Second reference or the previously selected clock source traceable to primary to be available after 15 sec.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify that SyncE and ESMC/eESMC are up.</li> <li>2. Device should be Frequency synchronized to tester via Link1.</li> <li>3. Verify the maximum phase-transient at the output of the device under test. <ol style="list-style-type: none"> <li>a. Result should meet ITU-T G.8262/G.8262.1 mask.</li> <li>b. The overall output phase error should remain constant and smaller than 170ns for G.8262.1 clock and 1000ns for G.8262 clock.</li> </ol> </li> </ol> | | | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the measurement result is below the limit specified by ITU-T G.8262/G.8262.1 clock specifications. | | | +| <b>Test Output</b> | This section is the placeholder that will capture the output/configurations after test is executed, typically done after test execution | | | + +## Annex B: ITU G.8273.2 Clock specification test cases for TNEs + +PTP performance as per G.8273.2 clock specifications + +### B.1 Time Noise Generation Performance + +| Test ID | SYNC.SE.06 | Classification | Synchronization, Performance, TIE/MTIE | +|--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------|----------------------------------------| +| Test Title | Time Noise Generation Performance | | | +| Test Objective: | Verify the Max TE , cTE, dTE of the HSR/CSR | | | +| Pre-Req | HSR/CSR connected to a Clock tester which uses a high-quality stable reference clock. | | | +| Test Topology: | <img alt="Test Topology Diagram: A GNSS satellite icon points to a 'Reference' box. The 'Reference' box points to a 'Clock Tester' box. The 'Clock Tester' box is connected to an 'HSR/CSR' box via two links, 'Link1' and 'Link2'. Both links are labeled 'CC=6'. The 'HSR/CSR' box contains 'T-BC/EEC/eEEC'. A '1PPS' signal line connects the 'HSR/CSR' box back to the 'Clock Tester' box." data-bbox="427 801 1348 1272" src="8ca6fefa61e09ce8031ca848f970da94_img.jpg"/> | | | +| Test Configuration | This section to be filled out when putting the test report (may include device and/or tester configuration) | | | +| Procedure: | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect the tester to HSR/CSR fronthaul interface as per the Topology.</li> <li>2. Configure tester as TimeTransmitter on the link1 and TimeReceiver on the link2.</li> <li>3. Establish Frequency and Phase Synchronization on DUT.</li> <li>4. Perform the noise-generation test for duration of 1000 sec or more.</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify both frequency and phase lock on device under test.</li> <li>2. Verify the time error performance as per ITU-T G.8273.2 <ol style="list-style-type: none"> <li>a. Frequency measurement should be as per ITU-T G.8262/G.8262.1 EEC/eEEC.</li> <li>b. For enhanced TE specifications, the device conforms following Class-C specifications. <ol style="list-style-type: none"> <li>1. Maximum 2way absolute Time Error of 30 nsec.</li> <li>2. Constant Time Error of +/-10 nsec.</li> <li>3. Dynamic Time Error (Filtered) for low and high frequency 10 nsec and 30 nsec respectively.</li> </ol> </li> </ol> </li> </ol> | | | + +| <p>4. Dynamic MTIE (LF) should be as per G.8273.2 mask.</p> <p><b>NOTE:</b><br/> For TNEs doesn't support enhanced Class-C TE specifications shall support either Class-A or Class-B specifications as per ITU-T G.8273.2.</p> | | | | | | | | | | | | | | | | | | | | | | | | | +|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------|----------------|--|--|---------|---------|---------|--------------------------------|---------|--------|--------|-------------------------------------|---------|---------|---------|--------------------------------|--------|--------|--------|--------------------------------|--------|--------|--------| +| <b>Pass/Fail Criteria:</b> | Test shall pass if the measurement result is below the limit specified by ITU-T G.8273.2 clock specifications. | | | | | | | | | | | | | | | | | | | | | | | | +| <b>Test Output</b> | <p>This section is the placeholder that will capture the output/configurations after test is executed, typically done after test execution</p> <table border="1"> <thead> <tr> <th rowspan="2">Time Error Limit</th> <th colspan="3">Expected Value</th> </tr> <tr> <th>Class-A</th> <th>Class-B</th> <th>Class-C</th> </tr> </thead> <tbody> <tr> <td>Max Time Error-2WAY ( Max TE )</td> <td>≤ 100ns</td> <td>≤ 70ns</td> <td>≤ 30ns</td> </tr> <tr> <td>Constant Time Error-2WAY (cTE-2WAY)</td> <td>≤ ±50ns</td> <td>≤ ±20ns</td> <td>≤ ±10ns</td> </tr> <tr> <td>Dynamic Time Error-HF (dTE-HF)</td> <td>≤ 70ns</td> <td>≤ 70ns</td> <td>≤ 70ns</td> </tr> <tr> <td>Dynamic Time Error-LF (dTE-LF)</td> <td>≤ 40ns</td> <td>≤ 40ns</td> <td>≤ 10ns</td> </tr> </tbody> </table> | Time Error Limit | Expected Value | | | Class-A | Class-B | Class-C | Max Time Error-2WAY ( Max TE ) | ≤ 100ns | ≤ 70ns | ≤ 30ns | Constant Time Error-2WAY (cTE-2WAY) | ≤ ±50ns | ≤ ±20ns | ≤ ±10ns | Dynamic Time Error-HF (dTE-HF) | ≤ 70ns | ≤ 70ns | ≤ 70ns | Dynamic Time Error-LF (dTE-LF) | ≤ 40ns | ≤ 40ns | ≤ 10ns | +| Time Error Limit | Expected Value | | | | | | | | | | | | | | | | | | | | | | | | +| | Class-A | Class-B | Class-C | | | | | | | | | | | | | | | | | | | | | | +| Max Time Error-2WAY ( Max TE ) | ≤ 100ns | ≤ 70ns | ≤ 30ns | | | | | | | | | | | | | | | | | | | | | | +| Constant Time Error-2WAY (cTE-2WAY) | ≤ ±50ns | ≤ ±20ns | ≤ ±10ns | | | | | | | | | | | | | | | | | | | | | | +| Dynamic Time Error-HF (dTE-HF) | ≤ 70ns | ≤ 70ns | ≤ 70ns | | | | | | | | | | | | | | | | | | | | | | +| Dynamic Time Error-LF (dTE-LF) | ≤ 40ns | ≤ 40ns | ≤ 10ns | | | | | | | | | | | | | | | | | | | | | | + +## B.2 Time Noise Tolerance Performance Test + +| | | | | +|---------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------|----------------------------------------| +| <b>Test ID</b> | SYNC.SE.07 | <b>Classification</b> | Synchronization, Performance, TIE/MTIE | +| <b>Test Title</b> | Time Noise tolerance Performance | | | +| <b>Test Objective:</b> | Verify the device Time Noise tolerance performance | | | +| <b>Pre-Req</b> | HSR/CSR connected to a tester which uses a high-quality stable reference clock.<br>Stimulus for input time noise to be enabled in the tester. | | | +| <b>Test Topology:</b> | <p>Image: Test Topology Diagram: A GNSS antenna points to a 'Reference' block. The 'Reference' block connects to a 'Clock Tester' block. The 'Clock Tester' block connects to an 'HSR/CSR' block via 'Link1' and 'Link2'. Both links are labeled 'CC=6'. The 'HSR/CSR' block also outputs a '1PPS' signal back to the 'Clock Tester'.</p> | | | +| <b>Test Configuration</b> | This section to be filled out when putting the test report (may include device and/or tester configuration) | | | +| <b>Procedure:</b> | <p><b>Detailed Test procedure:</b></p> <ol style="list-style-type: none"> <li>1. Connect the tester to HSR/CSR fronthaul interface as per the Topology.</li> <li>2. Configure tester as TimeTransmitter on the link1 and TimeReceiver on the link2.</li> <li>3. Establish Frequency and Phase Synchronization on DUT.</li> <li>4. Perform the time noise tolerance test for duration of 1000 sec or more.</li> </ol> | | | + +| | | +|----------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| | <p><b>Verifications needed:</b></p> <ol style="list-style-type: none"> <li>1. Verify both frequency and phase lock on device under test.</li> <li>2. Criteria for noise tolerance test as per G.8273.2 specification <ol style="list-style-type: none"> <li>a. Device should maintain the performance within limits.</li> <li>b. Device shouldn't lose lock/no alarm/no reference switch-over with the input wander.</li> <li>c. Device shouldn't move to holdover state.</li> </ol> </li> <li>3. Verify the time error performance as per ITU-T G.8273.2 <ol style="list-style-type: none"> <li>a. Frequency measurement should be as per ITU-T G.8262.1 eEEEC.</li> <li>b. For enhanced TE specifications, the device conforms following Class-C specifications. <ol style="list-style-type: none"> <li>1. Maximum 2way absolute Time Error of 30 nsec.</li> <li>2. Constant Time Error of +/-10 nsec.</li> <li>3. Dynamic Time Error (Filtered) for low and high frequency 10 nsec and 30 nsec respectively.</li> <li>4. Dynamic MTIE (LF) should be as per G.8273.2 mask.</li> </ol> </li> </ol> </li> </ol> <p>NOTE:<br/>For TNEs doesn't support enhanced Class-C TE specifications shall support either Class-A or Class-B specifications as per ITU-T G.8273.2.</p> | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the measurement result is below the limit specified by ITU-T G.8273.2 clock specifications. | +| <b>Test Output</b> | This section is the placeholder that will capture the output/configurations after test is executed, typically done after test execution | + +## B.3 Time Holdover Performance Test + +| | | | | +|------------------------|--------------------------------------------------------------------------------|-----------------------|----------------------------------------| +| <b>Test ID</b> | SYNC.SE.08 | <b>Classification</b> | Synchronization, Performance, TIE/MTIE | +| <b>Test Title</b> | Time holdover Performance | | | +| <b>Test Objective:</b> | Verify the device Time holdover performance (Physical Layer Assisted) | | | +| <b>Pre-Req</b> | HSR/CSR connected to a tester which uses a high-quality stable reference clock | | | + +| | | +|----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>Test Topology:</b> | <img alt="Test Topology Diagram: A GNSS satellite icon points to a 'Reference' box. The 'Reference' box points to a 'Clock Tester' box. The 'Clock Tester' box is connected to an 'HSR/CSR' box via two links: 'Link1' (labeled CC=6) and 'Link2' (labeled CC=135). A red lightning bolt icon labeled 'Interruption in PTP Flow' is shown between the links. A '1PPS' signal line connects the 'HSR/CSR' box back to the 'Clock Tester' box. The 'HSR/CSR' box contains sub-components 'T-BC/EEC/eEEC'." data-bbox="427 257 1348 728" src="b023d5c06190e42e864d466d8fb5c9d4_img.jpg"/> | +| <b>Test Configuration</b> | This section to be filled out when putting the test report (may include device and/or tester configuration) | +| <b>Procedure:</b> | <p><b><u>Detailed Test procedure:</u></b></p> <ol style="list-style-type: none"> <li>1. Connect the tester to HSR/CSR fronthaul interface as per the Topology.</li> <li>2. Configure tester as TimeTransmitter on the link1 and TimeReceiver on the link2.</li> <li>3. Apply a stable time and frequency from the Tester to DUT input.</li> <li>4. Establish Frequency and Phase Synchronization on DUT.</li> <li>5. Perform the holdover test for duration of 1000 sec or more (Stopping the PTP flows)</li> </ol> <p><b><u>Verifications needed:</u></b></p> <ol style="list-style-type: none"> <li>1. Verify both frequency and phase lock on device under test (HSR/CSR) after stopping the PTP Flow, <ol style="list-style-type: none"> <li>a. PTP should be in holdover state.</li> <li>b. Frequency should be in Locked state.</li> </ol> </li> <li>2. Verify the time error performance as per ITU-T G.8273.2 <ol style="list-style-type: none"> <li>a. Frequency measurement should be as per ITU-T G.8262.1 eEEEC.</li> <li>b. For enhanced TE specifications, the device conforms following Class-C specifications. <ol style="list-style-type: none"> <li>1. Maximum 2way absolute Time Error of 30 nsec.</li> <li>2. Constant Time Error of +/-10 nsec.</li> <li>3. Dynamic Time Error (Filtered) for low and high frequency 10 nsec and 30 nsec respectively.</li> <li>4. Dynamic MTIE (LF) should be as per G.8273.2 mask.</li> </ol> </li> </ol> </li> <li>3. Verify the MTIE mask defined as per ITU-T G.8273.2.</li> </ol> <p>NOTE:<br/>For TNEs doesn't support enhanced Class-C TE specifications shall support either Class-A or Class-B specifications as per ITU-T G.8273.2.</p> | +| <b>Pass/Fail Criteria:</b> | Test shall pass if the measurement result is below the limit specified by ITU-T G.8273.2 clock specifications. | +| <b>Test Output</b> | This section is the placeholder that will capture the output/configurations after test is executed, typically done after test execution | + diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/044606d87da1d09fbbc699aad677ac78_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/044606d87da1d09fbbc699aad677ac78_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..35f9e7049190afb2261bb34eb078f257f1280ce3 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/044606d87da1d09fbbc699aad677ac78_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:81f627d505022af86052b5efe2afe19fd3775b79596b2e314598c8334c5b865f +size 3534 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/050453256732154319e894d3ca2c8525_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/050453256732154319e894d3ca2c8525_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..2a45f293665eeb693817a2fcdc22575ea93101fc --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/050453256732154319e894d3ca2c8525_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7e603e8819fb3f10ad6b8fc0263c7c9687b8cb389d88a13b8e9da9e058a5364e +size 35254 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/06c3ed14587bdbcd17c049ed26f09659_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/06c3ed14587bdbcd17c049ed26f09659_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1fcb80efd62e53cf07d6aad1023bfe6a37023314 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/06c3ed14587bdbcd17c049ed26f09659_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3e122abe81d56c71d2a058e3ccdc68dce713420ec4bbd64b405bc693f9b25116 +size 3853 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/074b1f1fa3e943c91a68a92bee042341_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/074b1f1fa3e943c91a68a92bee042341_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5d98a2366ba8f1565dc9bcaed38c73f390997c3a --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/074b1f1fa3e943c91a68a92bee042341_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54d0fa2bac56af408aefbd7aa287c3a8fdec9526ce4051df6556ff77c72b724f +size 47118 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..19f401a5cfbf08aa0ec7781203e69177a2b7e39d --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/0a618fdb38d67ceab5ef8ed8ff6e7080_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5836b6268e1b6d229168b5e47faaaafd32832660ba85975f8ee7a6e10fc63fff +size 4560 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/0e0b355935cc7b204a0a7667300d94ca_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/0e0b355935cc7b204a0a7667300d94ca_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..18254c8373e2654fb925f6272046956449b430cc --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/0e0b355935cc7b204a0a7667300d94ca_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:56bb31acc51fa3b719f594fdc8fc98e83295693a5cfcd0e2c2b84cd294c1d17a +size 2722 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/14e40a84f98b05795aac8457fc3d123c_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/14e40a84f98b05795aac8457fc3d123c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..754b61f22573a088aa0f91659b6891018abc092e --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/14e40a84f98b05795aac8457fc3d123c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ce8450b376836241af1fa96a1178f72bc17617b07ab621828336a6a404073a66 +size 4471 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/15afb3e3af69290f2367d001a47abb08_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/15afb3e3af69290f2367d001a47abb08_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4803a693b5573c3beffb9cb223f34ab69ac324be --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/15afb3e3af69290f2367d001a47abb08_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:08123f3e7b5483ab2992a3d192b833f1bd02a65adea2c398aef547954fecb1a6 +size 58933 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/168a99f34654ddff7d1eb326bd3ba8c0_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/168a99f34654ddff7d1eb326bd3ba8c0_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..63ad09525151f1b616d882d1731b663c0ae08226 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/168a99f34654ddff7d1eb326bd3ba8c0_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5cfd9583d3716a15d199d06887141d7e7b37e75b6c1622037b4628332dbfb974 +size 34200 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/186f4dc8e289708d7c5e6c23fd9ae5f2_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/186f4dc8e289708d7c5e6c23fd9ae5f2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9050d4904519ed81bdb805bfc2352a8d7e9fc290 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/186f4dc8e289708d7c5e6c23fd9ae5f2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0569d92edbeaf3a747670fd00ff04a0cb21b3b67c4f42e5c38d1f60ec583cbce +size 2052 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..032c62eb806af57b7e5ee66cb887ea334d645367 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/258dfd0d115e4e1b3a2f8339efc2d10c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2b564b04424999ef27f28fbe08c12b8052d2115cb828103bf0565680c0ce7adf +size 4548 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/25f267f255d2fe4257531b79252a3669_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/25f267f255d2fe4257531b79252a3669_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c9bf6ece1aa1b3d7a5a8cb3795299500d38b1143 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/25f267f255d2fe4257531b79252a3669_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c1a8916b02b447e912394dc2b23fc4b1cfb06cd1f0a25fbb4084f7515621ca94 +size 4556 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2737c04e24c51f2f3cecaccdceb23515_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2737c04e24c51f2f3cecaccdceb23515_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..1253b9bfde87b8ff1d6dc1bd2e52b35f18e5c1d0 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2737c04e24c51f2f3cecaccdceb23515_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ea408516653d5c58f056aa3bc750a30ec3feaa5cc7398b96db9d5e30be4854e5 +size 47846 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e20d85525829ce0ee72f0f1e7d337440c0022085 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/29927b149ca678e36f117a6e08fd32d5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:70202500dcd1d7555a287caab20530fcb4adfd35aaacfd59604999379d6de583 +size 4432 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2acdaa24e06a2484722735c1a2f42e49_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2acdaa24e06a2484722735c1a2f42e49_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..55ee5296d24e99ae293e1ce1fe82e821786bd83f --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2acdaa24e06a2484722735c1a2f42e49_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fd1f7a3aca9ae8a69cd95996def44479168ed26cf7e692fad0bff0e2746a443c +size 62232 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2ec5225bbece9e125a50bd7b410149f6_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2ec5225bbece9e125a50bd7b410149f6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..4de5c861a04c58b4b87c349f91fde9d2dd2cd3b1 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2ec5225bbece9e125a50bd7b410149f6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cca08ef06db45c951f16112e61da9a57716eb51c72aedeeafd132a8f5b4d6941 +size 44276 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2f13584546a4e770ea62380988930e8f_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2f13584546a4e770ea62380988930e8f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7719a87580e9d9209824e63f64248f9da0771016 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2f13584546a4e770ea62380988930e8f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3434759a58ae58ca64cbb4f2f73213c94cc738a583e9556b73e0d0b71ca25f25 +size 53270 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2f744edebc59b0fc4b5a472d52bb9b9a_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2f744edebc59b0fc4b5a472d52bb9b9a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..91bc636dee239691da867a29592e9bee3edbd840 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/2f744edebc59b0fc4b5a472d52bb9b9a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c2c3eef57071eb121d3893fec37fe700719c72486db204805aec361e2b0ec582 +size 23682 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/37da6628bdc4823e211405f1278acfb4_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/37da6628bdc4823e211405f1278acfb4_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..5414c6e165c3f979bf31ca14205aa00f4a7d8659 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/37da6628bdc4823e211405f1278acfb4_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:71f1f9631acea47b33a1e72ccf2bb72966d85695ab88655cd0749efdc29f41ac +size 21816 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/37e525c3d536489308cae682cd6701ff_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/37e525c3d536489308cae682cd6701ff_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b65c9819ba60bfe19f6cdb95d3075d756b2b6c71 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/37e525c3d536489308cae682cd6701ff_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0cad14f9ac2225f628dcfe49bccbde098fb99facc8adc2cec5e351074d1e3eee +size 4528 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/38d75c776a991761f5a5dbf748c14e29_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/38d75c776a991761f5a5dbf748c14e29_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d1c19eaad6b7418c0e1698746d8902c74ed891d0 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/38d75c776a991761f5a5dbf748c14e29_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd946d90cfa85e6e260f0511a886c00f12287b9f92bd34b4fad227f6021b6f35 +size 4558 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/3bed333618a7f55307c9375e85c73ff6_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/3bed333618a7f55307c9375e85c73ff6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..14caee444fca0735e365d42e2c1b1191e796ddd1 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/3bed333618a7f55307c9375e85c73ff6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e44ee24f8268cc6d281a70f781b4bafc11dbb22e9402bd63a619c42d53c1082a +size 2169 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/3c29d92e4e25a999b86146771f08e6a5_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/3c29d92e4e25a999b86146771f08e6a5_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..9e99f251b964e129e10def2265819a02beee6ce7 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/3c29d92e4e25a999b86146771f08e6a5_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:efee8c3536b0363224a302da925c69ca88b7153c41cb84d498aa684996bfca6f +size 24126 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/42635a3467ae8c12d3d176f1e7422b6c_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/42635a3467ae8c12d3d176f1e7422b6c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..b469efd332699b0772e254651854d6d006dbc8fd --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/42635a3467ae8c12d3d176f1e7422b6c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09108669f9c8240a0c83a234ebf6e106359e5e8861b9163dfddb9a88ea643399 +size 27370 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/4f7a4667ae1b406aedf697e6f527a120_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/4f7a4667ae1b406aedf697e6f527a120_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c04647a79c4a5069b83b05da28fded12e2c62a5c --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/4f7a4667ae1b406aedf697e6f527a120_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:38482d2c53c96d512d2862a0713a4d9e94d61da36192434461e0eb463b3cd4b5 +size 2309 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/56d67cea5e4ef68d58932b36f0b7d13e_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/56d67cea5e4ef68d58932b36f0b7d13e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..13bf4e8fa0a786f94bb66e7e38a97e1ef036f604 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/56d67cea5e4ef68d58932b36f0b7d13e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:193a4b10602d10be663ef9ddc1258b62f4f24b409f4464faf885a630a61d0605 +size 57699 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/579a54c9653962940ffe4bfd0853efcd_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/579a54c9653962940ffe4bfd0853efcd_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d7d578730aeeeba9717048f09829d1d9707358be --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/579a54c9653962940ffe4bfd0853efcd_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ea2a3b54de9eff88aed169866574546333ba47a860512d3501fe0633f6a76bdc +size 2792 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/64165b6fda77ddb7433e931fc3af26c9_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/64165b6fda77ddb7433e931fc3af26c9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a0f3e447a52dd6c0ea7756bcb66a2a76d8e01f99 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/64165b6fda77ddb7433e931fc3af26c9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:24c2ddc2ddf30b475f9433f5b20fc92639e379c2a0b008dc0f4cb359c7a0e436 +size 37741 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/6a60ae9f8e5f0b73275b448938b77626_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/6a60ae9f8e5f0b73275b448938b77626_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e9ac95cba9aebb02c2ff8fbf0d42a58e0a7c2fd4 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/6a60ae9f8e5f0b73275b448938b77626_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2725e1526eea377b9cddac9b58a91d2a188adfce1c46dee5f4e5697517ed53c3 +size 61904 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/6b54d76e748b0d137dd01a3c6f53adcf_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/6b54d76e748b0d137dd01a3c6f53adcf_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..61295c7863a9aba791d02dc3c879613b1d3226bf --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/6b54d76e748b0d137dd01a3c6f53adcf_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8ef390502ba25a7d6085d3a5e7b6d5ccc136d85147a6ea93728125b53b1fbdc0 +size 3272 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/7641f3461e8409bf6c6d04273f0e9851_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/7641f3461e8409bf6c6d04273f0e9851_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a2f2466cacbb8a1840a9fe80a5eece9b5eafe9df --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/7641f3461e8409bf6c6d04273f0e9851_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b9699c3eaab62eb62e0a13f3a1add02a38694e5132b5bebadd41ac11e9022aa5 +size 33808 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/76857c84b720a1d2c703c074e93b91bb_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/76857c84b720a1d2c703c074e93b91bb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0ca7b322e0750987b08cb906ae8101a16cceb234 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/76857c84b720a1d2c703c074e93b91bb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:de4af767893acb8cc18aaee0a5ec571745fba8ae3ceab68ab655c2040dec37b6 +size 13282 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/769f6230a2e5ded1245b07d7424fa29d_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/769f6230a2e5ded1245b07d7424fa29d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..e4a1ef5a3cfd3927c2e343ffc15daab9fd0ad2e5 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/769f6230a2e5ded1245b07d7424fa29d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:575a8f95c74fd3701453b1f9c389a01394aa28adbedd80cf0dbb9c9c3bd380ad +size 60559 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/772fd1b3c0b0e6c4503e428b30847746_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/772fd1b3c0b0e6c4503e428b30847746_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..25510da489b3b59de7728789cab206cbcccd8b97 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/772fd1b3c0b0e6c4503e428b30847746_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d3bc9af4ba2da67bbcd33daeb319249706028012deeb2b3adf23f2f8f8a773ac +size 3344 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/78d159ef968e015c92aa5dbfe2dff566_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/78d159ef968e015c92aa5dbfe2dff566_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..67bf529514617d6051f8afe8a64d7e50a664816b --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/78d159ef968e015c92aa5dbfe2dff566_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d05d33f797e6f28b627256d3c3f55f963ca0b808f69d05e08907af3242c354f5 +size 33143 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/7bc652502bda3fe1196b0faae7b2d8ac_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/7bc652502bda3fe1196b0faae7b2d8ac_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a83524b0defbfb253454390d7c1a1e1200315206 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/7bc652502bda3fe1196b0faae7b2d8ac_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6a5f02f198bdf514e5287ef7e7e709688f5f974aa2d351e97e3aea4d7544def5 +size 69936 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/890db1757fc1e53b51d29aef2bf3a43e_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/890db1757fc1e53b51d29aef2bf3a43e_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..980cafb6d72edac8c971fb5248369aa6aed6ed38 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/890db1757fc1e53b51d29aef2bf3a43e_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:230b2dde036f32a6d0117014377eb99f7339d217d7212f4adb4bc264bd5d77a5 +size 35513 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/8f88304ab70b551d8926032c99b4217c_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/8f88304ab70b551d8926032c99b4217c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..7c15546c1411d96b557af9679c3e6c3777628e4b --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/8f88304ab70b551d8926032c99b4217c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:eb4b4ccf89b14c988430bb2e00be11cb7315cdbdb1695c447af19e9d4ccfbea0 +size 3220 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/92650750ae5925b274f05db95ce5880f_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/92650750ae5925b274f05db95ce5880f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3070d2920f95afb8512147ade8ebd447d768d9da --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/92650750ae5925b274f05db95ce5880f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2baf1eeec029b293576e0f3416a5fa59522e69fadd6cdae7b1dc183b1a99fdb9 +size 38692 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/9587b931521cbef1dc97ae2acb1278fb_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/9587b931521cbef1dc97ae2acb1278fb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..ec5fde0eb524e2e5481abf28ba4923f8b380a75b --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/9587b931521cbef1dc97ae2acb1278fb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d86f657e9267a1d8d6c28e15e440c6daffcb4dfa0fe876765c7a847807d5d314 +size 25369 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..12e490161b1ca814d948b6b2f7176bf9e027eee1 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/97ac85138c467345e5ea1960ed02fd6d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7cd4f22da9bbed8aed363cc4fa0298bef3fb68bd57d3cbef3c29081f0466bc2 +size 4432 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/9c58a6c1b6d09675a32b8302e12b5a33_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/9c58a6c1b6d09675a32b8302e12b5a33_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..30e044ea7204e1ce804475b4bdb8c29e8e97dfe1 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/9c58a6c1b6d09675a32b8302e12b5a33_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8a2096a783c37fc9535528d5743f6f7f531991a2fbcf99ab25f9c0436e3b2fe9 +size 42128 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a10f11c3136df6da56ecea0b62f6fbf9_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a10f11c3136df6da56ecea0b62f6fbf9_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3723f81f59b9585126cb26dfd755979c2bf38304 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a10f11c3136df6da56ecea0b62f6fbf9_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5fc45eec611989996dceec1136313651d929a8bb79bbb598ae524b59e654b1ca +size 19530 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a144eae851ef56734d1cf505c4b60281_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a144eae851ef56734d1cf505c4b60281_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..3b7540ad3b5b8f47ffe562951ff5a082533f0b05 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a144eae851ef56734d1cf505c4b60281_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f9ac07077a3cce57654754915f75c12ec0f417e778be4b1c15ae85f4112ed022 +size 3203 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a50940799e538c86d1b58e13ef2f9d47_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a50940799e538c86d1b58e13ef2f9d47_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..940ef4bf6da879a868f0e553e07ac0d12682096b --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a50940799e538c86d1b58e13ef2f9d47_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:07737154f4c17715c8a502c6c37ca0b0db7ebe28ba235bf0f84b2603a892cc3f +size 34997 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c3d86fb0327196a9f4e535de607f9679893b3bb5 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a6c0135253a4ad6ecc2789d2a3e51a99_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1aa7b7ea2d2f7a405b9ed225a9d75ba10a49558f5daba7eec5731fe0cfefc643 +size 4531 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a80d9532823171e3cfe0d3d46c5fff9a_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a80d9532823171e3cfe0d3d46c5fff9a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..fa497985b1cb0bdb595c65c98166210eec8e2b00 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/a80d9532823171e3cfe0d3d46c5fff9a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:68bab94f2d826c1f66a7e19da9642f6cbd9cfcae2b7547e51d9e5a1229302577 +size 4501 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/ab00edbcf5418abdea6fa92c4e3b3498_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/ab00edbcf5418abdea6fa92c4e3b3498_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..abfdb88c25cdc657cadaa2993b42998d1e227cf7 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/ab00edbcf5418abdea6fa92c4e3b3498_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1b59674f27a295937362a152753eeb48ea7db3ceb3256e91345f80ee66ba97b0 +size 71762 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/ac167b387be955f9f473383f96aa48b6_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/ac167b387be955f9f473383f96aa48b6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0b165662f12d4bd0bba3d511e66c72f77f7006e8 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/ac167b387be955f9f473383f96aa48b6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b1cdd93415d9ff8ce5bcc33bd563d211a96115c0ac4986042fde58b1140351df +size 34875 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/b3ebb28d2ead2be7e45b5b5bccb35892_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/b3ebb28d2ead2be7e45b5b5bccb35892_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a4bc028b7f6499a38f0d852c42ebdcab8e99a36a --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/b3ebb28d2ead2be7e45b5b5bccb35892_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:12916dc4db13261bead942f30dba90a074a6509a0759372ab822a6d5a91d27ba +size 4096 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/b8a10d74cce8c0b450445cf52faf78e1_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/b8a10d74cce8c0b450445cf52faf78e1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..17b5a300b80d376cb30c8029c119e57452442595 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/b8a10d74cce8c0b450445cf52faf78e1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:81936989e22aa976d2d27edeb6041e8e6a62ed1af091604ad0bc0a4d0aad19f0 +size 30404 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a7575c364a05dd515d7cf096c30ffc26f8ab2631 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/bd79f2dac518ad9ed6d988e0b726be1f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b321cfff0a169d11fa6daa2e14ee4667e12bcfeff34e35ee9dd80b810a6385a6 +size 4491 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/be9cec6e16a8e660e292257af70652cb_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/be9cec6e16a8e660e292257af70652cb_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..a8f7def13642c60236136114ee34dc73a2829c41 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/be9cec6e16a8e660e292257af70652cb_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3552d216c17b965330dfaa2f571b7f1be536ea61d3594b471c8df73897641125 +size 44710 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/c0ad355d72c457db2044f8927b5ec0c6_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/c0ad355d72c457db2044f8927b5ec0c6_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8c8a70f8c4cb218fe8348988eaa67039d57ab5f3 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/c0ad355d72c457db2044f8927b5ec0c6_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6456c2ec9c91960f17a837b000c9e88fb47f544b21aa26e4db6d4ba9948fdb4a +size 2843 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/cd27028e0175f9d3a05cb51f253fd1db_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/cd27028e0175f9d3a05cb51f253fd1db_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bf99308f8fd227a81215270800b8ca37334dbd79 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/cd27028e0175f9d3a05cb51f253fd1db_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:8ae355a828e24648420335eebad1c016ddef36865c0cd049fd9c9604199d8cb5 +size 30910 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..bbac3f74585500c365ef456083c9a2409c93efcf --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/d0c14999fe6c2be01dafe5f48f294ad2_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:da90a99cb378325f209d81ac7f1fc9bd173026b70a83efe6352146fd717c5170 +size 4533 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/da4af3c1282df1a27f0b0fe00bcf2361_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/da4af3c1282df1a27f0b0fe00bcf2361_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..402da0fb68dcb1d484ebfc45b22f0c8bc5e25fd5 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/da4af3c1282df1a27f0b0fe00bcf2361_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:db4ba8c9162d59bf953614bcf0081b7630853213062668b3138e168246fad399 +size 16806 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/dcff3919f3d431813acd0258d76c6a5c_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/dcff3919f3d431813acd0258d76c6a5c_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d425bd37ef999c026ab18a0799209e8517204ad0 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/dcff3919f3d431813acd0258d76c6a5c_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f65801d76670192e019b377af6eb346d3d809a72548281a9c09112daead8f8e8 +size 25705 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/e2b94d6f73bb689060b4109d9c8b193b_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/e2b94d6f73bb689060b4109d9c8b193b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..283c7ed3d0bad5a6f26f05f2a1fda6710e9f6df0 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/e2b94d6f73bb689060b4109d9c8b193b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:618d7c14ae12c9ee8e960f92644f2d20449f3169bc5523fc29f8f8aa6e7eaf3e +size 38999 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/e54fd4c7a54e2814c73032279166c414_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/e54fd4c7a54e2814c73032279166c414_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..8ca6801d068b77203da16601f079eca8736a6358 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/e54fd4c7a54e2814c73032279166c414_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7dec72f1ee606562a295267edd9f8baf17946eb391cd16dbb47fa5bcd1ada240 +size 44109 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/e9bdfe9ab6ae256f2fa2c6cb8ae02a0a_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/e9bdfe9ab6ae256f2fa2c6cb8ae02a0a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..aa14c61521b1abbd857e256af9c4c900536010f4 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/e9bdfe9ab6ae256f2fa2c6cb8ae02a0a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:fee7e6bbeac63f3669c9967d5d62941bbce04ae4b2820792a81957a597910d83 +size 1960 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..0719d9b662dad25c29233ab2163d9df2777a7e0a --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/eb8333945620e56e3ccb8af8af60ac2d_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:48fc024d6159442c0a0007f6f8b66e2368910d5ddb2250bcf7fc34f695726411 +size 4492 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/ef23ace3221ee4132c5039b54e73a3da_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/ef23ace3221ee4132c5039b54e73a3da_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..22691be272780b5800a7a90a87dd878c542debfa --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/ef23ace3221ee4132c5039b54e73a3da_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:53f426405dc0187a2287d092133741bbe8472748c96b6c66bb9899f3799750ef +size 46730 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f1a6a7d2f59264715bc9a4280f5acf62_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f1a6a7d2f59264715bc9a4280f5acf62_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..50ba0c3b013049bfc26110ac15143cf0aea009c7 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f1a6a7d2f59264715bc9a4280f5acf62_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dff965311cacc50e7c63246b87a49e6b805b69d20de21d36f683dbf26afbcc6d +size 60107 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..602e94046000f14899adf3d1ab8d220a9635a879 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f2d3e37bc44f6b74ee40b0683ee8c0f1_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:64a304437f8e7342c4cde5ed3b8cdb9446ace6349aa993a67fa0f6b028d7188f +size 4499 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f35cde62508395a0d637afc0148ded4b_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f35cde62508395a0d637afc0148ded4b_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..c9e411af8b6da58626602bfb999a0cec8507d877 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f35cde62508395a0d637afc0148ded4b_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2708a26a1d6a75d43c2d331e5956c8089dfcfadaa0691d59a4ba8095baf872d0 +size 40321 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f5ebb1500382b31a296032b6cc633b3a_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f5ebb1500382b31a296032b6cc633b3a_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..cc1d9c229f8cc7898ed198a0a21e2dbdb143ded1 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f5ebb1500382b31a296032b6cc633b3a_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9ee2de3123658d1e22bca5657a4e9957cba8f152b6df2bb72a6ce7b2ff825d74 +size 2853 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f95bfd1fdd9b60c7a3df79b8df67414f_img.jpg b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f95bfd1fdd9b60c7a3df79b8df67414f_img.jpg new file mode 100644 index 0000000000000000000000000000000000000000..d841f3ab846d890518b90dba09aac5c5949559ed --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/f95bfd1fdd9b60c7a3df79b8df67414f_img.jpg @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f1886ac7911a2bb3d2cff6d11ca58893e9a78ce7b9740860c88d8d13f11ebde5 +size 28330 diff --git a/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/raw.md b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/raw.md new file mode 100644 index 0000000000000000000000000000000000000000..0f8ec1ad318738e38671b81d27f5a256242f5070 --- /dev/null +++ b/marked/WG9/ORAN-WG9.WDM.0-R004-v05.00/raw.md @@ -0,0 +1,1797 @@ + + +# O-RAN Open Xhaul Transport WG9 + +## WDM-based Xhaul Networks --- + +Copyright © 2024 by the O-RAN ALLIANCE e.V. + +The copying or incorporation into any other work of part or all of the material available in this specification in any form without the prior written permission of O-RAN ALLIANCE e.V. is prohibited, save that you may print or download extracts of the material of this specification for your personal use, or copy the material of this specification for the purpose of sending to individual third parties for their information provided that you acknowledge O-RAN ALLIANCE as the source of the material and that you inform the third party that these conditions apply to them and that they must comply with them. + +O-RAN ALLIANCE e.V., Buschkauler Weg 27, 53347 Alfter, Germany + +--- + +| Author | Company | +|-------------------|-------------------------| +| Dr. Dechao Zhang | China Mobile | +| Ricky Perry | AT&T | +| Dr. Dong Wang | China Mobile | +| Fabienne Saliou | Orange | +| Philippe Chanclou | Orange | +| Likai Zhu | Fiberhome Telecom USA | +| Martin Birk | Highstreet Technologies | +| Jim Zou | Adtran | +| Reza Vaez-Ghaemi | VIAVI Solutions | +| Shikui Shen | China Unicom | + +# Revision History + +| Date | Revision | Author | Description | +|------------|---------------|----------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------| +| 2020/04/01 | v.01 | Dechao Zhang, Dong Wang, Jun Ma, Zhen Han, Ricky Perry | Outline of WDM-based Fronthaul Transport specification | +| 2020/05/04 | v.02 | Dong Wang, Yi Jiang, Ricky Perry | Added Wavelength Allocation and Optical Channel Power Budget | +| 2020/07/23 | v.03 | Philippe Chanclou | Added contributions to chapter 5 | +| 2020/07/30 | v.04 | Likai Zhu, Zhen Han, Dong Wang, Philippe Chanclou, Fabienne Saliou | Added contribution to chapter 6 and revisions to chapter 5 | +| 2020/08/06 | v.05 | Philippe Chanclou<br>Fabienne Saliou<br>John DeAndrea,<br>Reza Vaez-Ghaemi | proposition of resolution of comments to chapter 6 following comments from the group (merged documents) | +| 2020/08/13 | v.06 | Philippe Chanclou | proposition of resolution of comments to chapter 6 following comments from the group (merged documents) | +| 2020/08/13 | v.07 | Ricky Perry | Added minimal Optic KPIs table for section and recommended feedback on section 6.1, Chapter 8 X-Haul Synchronization Solution | +| 2020/8/21 | v.09 | Ricky Perry | Included Dispersion, Revised DWDM Power budget table | +| 2020/9/23 | v.10 | Ricky Perry | Updated with all the authors inputs/edits (Orange CH5, 6) | +| 2020/9/23 | v.11 | Ricky Perry | Updated sections with CMCC and Highstreet Technologies Edits | +| 10/13/2020 | v.12 (v00.03) | Ricky Perry | Reviewed and made minor editorial changes in all sections, Proposed scope re-phrase | +| 10/26/20 | v00.05 | Ricky Perry | Final Edits: DWDM related sections, Chapter 7, | +| 10/30/20 | V00.06 | Reza Vaez-Ghaemi | Checked for consistency, and final editorial edits in all chapters. | +| 11/11/2020 | v01.00 | Reza Vaez-Ghaemi | Responses to comments from WG9 members incorporated, document cleaned up, and renamed. | +| 11/12/2021 | v02.00 | Ricky Perry | Included additions for phase 2. | +| 11/12/2021 | V02.00 | Reza Vaez-Ghaemi | Responses to comments from WG9 members incorporated, document cleaned up, and renamed. | +| 10/28/22 | V03.00 | Ricky Perry | Addressed comments from WG9 members, document cleaned up, and renamed | +| 9/8/23 | V03.01 | Ricky Perry | V4 initial draft content (25G BiDi and beyond, MOPA, Smart Tunable MSA) | +| 9/12/23 | V03.02 | Ricky Perry, Ken Cockerham, Reza Vaez-Ghaemi | Entered draft content in section 4.1.5 | +| 7/25/24 | V04.00 | Ricky Perry, Reza Vaez-Ghaemi | Phase 5 baseline | +| 9/19/24 | V04.01 | Ricky Perry | Initial draft ready for input | +| 9/19/24 | V04.02 | Stepan Dahlfort | Section 5.1.6 initial content entered | +| 9/26/24 | V04.02 | Sheng Liu | Section 2.1 initial content | +| 10/3/24 | V04.03 | Jim Zou | Section 5.1.7 | +| 10/3/24 | V04.03 | Jim Zou | Section 5.3.2 additional comment | +| 10/7/24 | V04.04 | Phillippe Chanclou | Section 5.3.2 additional comment | +| 10/17/24 | V05.00 | Jim Zou | Revision based on the first round review comments | + +# Contents + +| | | +|--------------------------------------------------------------|----| +| <b>Revision History</b> ..... | 3 | +| <b>1 GENERAL</b> ..... | 6 | +| 1.1 Scope..... | 6 | +| 1.2 References ..... | 6 | +| 1.3 Definitions and Abbreviations ..... | 7 | +| 1.3.1 Definitions..... | 7 | +| 1.3.2 Abbreviations ..... | 8 | +| <b>2 Phase 5 Backhaul and Midhaul (Xhaul)</b> ..... | 9 | +| 2.1 Application scenarios and technical trends..... | 9 | +| <b>3 Function Module of the (Fronthaul) Equipment</b> ..... | 10 | +| 3.1 Passive WDM..... | 10 | +| 3.2 Active WDM ..... | 11 | +| 3.3 Semi-Active WDM ..... | 11 | +| 3.4 Phase 2 WDM Protection ..... | 13 | +| <b>4 Wavelength Allocation</b> ..... | 14 | +| 4.1 MWDM Wavelength Allocation ..... | 14 | +| 4.2 DWDM Wavelength Allocation ..... | 15 | +| <b>5 Optical Equipment Technical Requirements</b> ..... | 19 | +| 5.1 Optical Transceiver Technical Requirements ..... | 19 | +| 5.1.1 MWDM..... | 20 | +| 5.1.2 DWDM21 | | +| 5.1.3 Phase 2 DWDM Tuneable Use Cases..... | 24 | +| 5.1.4 Phase 3 DWDM Smart-Tunable MSA..... | 26 | +| 5.1.5 Phase 4 DWDM SmartTunable MSA ..... | 26 | +| 5.1.6 Phase 5 MOPA Updates..... | 27 | +| 5.1.7 Phase 5 Beyond 25G WDM ..... | 28 | +| 5.2 Multiplexer / Demultiplexer Technical Requirements ..... | 29 | +| 5.2.1 MWDM..... | 29 | + +| | | +|---------------------------------------------------------------------------|-----------| +| 5.2.2 DWDM C-Band Example of a BiDi 40 Channel 100Ghz Mux/Demux ..... | 31 | +| 5.3 Phase 2 WDM >10 km link Budget 25G..... | 32 | +| 5.3.1 Phase 2 MWDM..... | 32 | +| 5.3.2 Phase 2 DWDM..... | 33 | +| 5.4 Phase 2 Optical Power Consumption ..... | 36 | +| 5.5 Phase 2 Optical Interfaces ..... | 36 | +| 5.5.1 Phase 2 Single and Duplex fiber solutions ..... | 37 | +| 5.6.0 Phase 3 Optical Link Budget ..... | 39 | +| 5.6.1 Phase 3 MWDM Link Budget..... | 39 | +| 5.6.2 Phase 3 DWDM Link Budget..... | 39 | +| <b>6 System Function and Performance Requirements.....</b> | <b>41</b> | +| 6.1 Latency and jitter ..... | 41 | +| 6.1.1 Phase 2 Latency Asymmetry ..... | 44 | +| 6.1.2 Phase 2 Latency Classification..... | 45 | +| 6.1.3 Phase 3 Asymmetry with WDM..... | 46 | +| 6.2 Bit Errors..... | 47 | +| 6.3 Protection ..... | 47 | +| 6.4 Synchronization ..... | 47 | +| 6.4.1 Phase 2 WDM delivery sync ..... | 48 | +| 6.4.2 Phase 2 OTDR-based latency characterization..... | 50 | +| 6.5 Maintenance and Operation..... | 52 | +| <b>7 Operation Administration Maintenance (OAM) Requirements .....</b> | <b>52</b> | +| 7.1 OAM Architecture ..... | 52 | +| 7.2 Configuration..... | 56 | +| 7.3 Enquiry..... | 57 | +| 7.4 Active..... | 57 | +| 7.5 Phase 3 OAM In Fronthaul..... | 57 | +| <b>8 Management Interfaces .....</b> | <b>59</b> | +| <b>Appendix A Phase 1 Optical Power Budget-.....</b> | <b>60</b> | +| <b>Appendix B Phase 2 >25G Line rate Cover it in an Appendix .....</b> | <b>63</b> | + +# --- 1 GENERAL + +## 1.1 Scope + +This Technical Specification has been produced by the O-RAN Alliance. This document is intended to describe best practices for O-RAN fronthaul transport based on WDM technology. It is recognized that other solutions, not based on WDM technology, could be employed or mixed with a WDM solution. Beyond the technologies in this document, other WDM solutions may be adequate for fronthaul transport networks and can be considered for future versions of this document. + +The contents of the present document are subject to continuing work within O-RAN WG9 and may change following formal O-RAN approval. Should the O-RAN Alliance modify the contents of the present document, it will be re-released by O-RAN with an identifying change of release date and an increase in version number as follows: + +Release x/y/.z + +where: + +- x the first digit is incremented for all changes of substance, i.e. technical enhancements, corrections, updates, etc. (the initially approved document will have x=01). +- y the second digit is incremented when editorial only changes have been incorporated in the document. +- z the third digit included only in working versions of the document indicating incremental changes during the editing process. + +The present document specifies the key recommendation/requirements of Wavelength Division Multiplexing (WDM) based fronthaul transport network. WDM is a transparent solution. + +Following introductory section 1, section 2 concentrates on the function module of the passive, active, and semi-active WDM equipment. Section 3 concentrates on the Medium Wavelength Division Multiplexing (MWDM) and Dense Wavelength Division Multiplexing (DWDM) wavelength allocation. Section 4 concentrates on the optical transceiver and multiplexer/demultiplexer technical requirements. The next three sections concentrate on system function and performance requirements, Operation Administration Maintenance (OAM) requirement, and Management interfaces, respectively. + +This document uses information published by O-RAN, 3GPP, IEEE, ITU-T, and several other relevant standard bodies and industry associations. It contains educational, informative, and normative content. + +## 1.2 References + +The following documents contain provisions that, through reference in this text, constitute provisions of the present document. + +- References are either specific (identified by date of publication, edition number, version number, etc.) or nonspecific. +- For a specific reference, subsequent revisions do not apply. + +- For a non-specific reference, the latest version applies. In the case of a reference to a 3GPP document (including a GSM document), a non-specific reference implicitly refers to the latest version of that document. +- [1] ITU-T G.694.1: "Spectral grids for WDM applications: DWDM frequency grid" +- [2] SmartTunable MSA: "Technical specification for Smart Tunable Modules"- [www.smarttunable-msa.org](http://www.smarttunable-msa.org) +- [3] ITU-T G.652: "Characteristics of a single-mode optical fiber and cable" +- [4] SFF-8431: "SFP+ 10 Gb/s and Low Speed Electrical Interface" +- [5] SFF-8432: "SFP+ Module and Cage" +- [6] SFF-8472: "Management Interface for SFP+" +- [7] SFF-8690: "Tunable SFP+ Memory Map for ITU Frequencies" +- [8] IEEE Std 802.3-2018 Annex 109B: "Chip-to-module 25 Gigabit Attachment Unit Interface (25GAUI C2M)" +- [9] IEEE Std 802.3-2018 Clause 105: "Introduction to 25 Gb/s networks" +- [10] O-RAN X-haul Transport Group, WG9: "Xhaul Transport Requirements" +- [11] Next Generation Mobile Networks (NGMN) Alliance: "FRONTHAUL REQUIREMENTS FOR C-RAN" +- [12] ITU-T G.988: "ONU management and control interface (OMCI) specification" +- [13] ITU-T G.989 Annex B: "40-Gigabit-capable passive optical networks 2 (NG-PON2): Physical media dependent (PMD) layer specification" +- [14] ITU-T G.989.3 Annex F & G: "40-Gigabit-capable passive optical networks (NG-PON2): Transmission convergence layer specification" +- [15] ORAN WG9 packet-based architecture and solutions +- [16] ORAN WG9 Management interface + +## 1.3 Definitions and Abbreviations + +### 1.3.1 Definitions + +For purposes of the present document, the following terms and definitions apply. + +<**TERM**: description of term> + +### 1.3.2 Abbreviations + +For the present document, the following abbreviations apply. + +| | | +|---------|--------------------------------------------| +| 3GPP | 3rd Generation Partnership Project | +| APD | Avalanche Photo Diode | +| BER | Common Public Radio Interface | +| CPRI | Common Public Radio Interface | +| CWDM | Coarse Wavelength Division Multiplexing | +| DML | Directly Modulated Laser | +| DWDM | Dense Wavelength Division Multiplexing | +| eCPRI | enhanced Common Public Radio Interface | +| FEC | Forward Error Correction | +| ITU-T | International Telecom Union | +| MCU | Microcontroller Unit | +| M plane | Management Plane | +| MWDM | Medium Wavelength Division Multiplexing | +| NGMN | Next Generation Mobile Networks | +| O-DU | O-RAN Distributed Unit | +| O-RU | O-RAN Radio Unit | +| OAM | Operation, Administration, and Maintenance | +| OD | Optical Demultiplexer | +| OM | Optical Multiplexer | +| OMA | Optical Modulation Amplitude | +| OTDOA | Observed Time Difference of Arrival | +| PD | Power Detector | +| PIN | P-type Intrinsic-N type | +| RMS | Root Mean Square | +| TDP | Transmitter and Dispersion Penalty | +| TEC | Thermo Electric Cooler | +| TFF | Thin-Film Filter | +| TNE | Transport Node Equipment | +| Tr | Transceiver | +| WDM | Wavelength Division Multiplexing | + +# 2 Phase 5 Backhaul and Midhaul (Xhaul) + +## 2.1 Application scenarios and technical trends + +Led by CMCC team. + +![Figure 1: WDM-based back-haul and mid-haul network architecture diagram. The diagram shows two parallel paths for mobile traffic. Each path starts with an AAU (Active Antenna Unit) connected to an AAU+RRU (Active Antenna Unit + Remote Radio Unit) via a 25G/10G interface. The AAU+RRU is connected to a DU+CU (Distributed Unit + Central Unit) via a 25G WDM interface. The DU+CU is connected to an Access network. The Access network is connected to an Agg (Aggregation) network. The Agg network is connected to a Core network. The Core network is connected to a cloud containing AMF (Access and Mobility Management Function), SMF (Session Management Function), and UPF (User Plane Function). The diagram also shows a PON (Passive Optical Network) connected to an OLT (Optical Line Terminal) and a Private line connected to the OLT. The OLT is connected to the Access network. The diagram illustrates the use of WDM technology in the backhaul and midhaul networks.](2737c04e24c51f2f3cecaccdceb23515_img.jpg) + +Figure 1: WDM-based back-haul and mid-haul network architecture diagram. The diagram shows two parallel paths for mobile traffic. Each path starts with an AAU (Active Antenna Unit) connected to an AAU+RRU (Active Antenna Unit + Remote Radio Unit) via a 25G/10G interface. The AAU+RRU is connected to a DU+CU (Distributed Unit + Central Unit) via a 25G WDM interface. The DU+CU is connected to an Access network. The Access network is connected to an Agg (Aggregation) network. The Agg network is connected to a Core network. The Core network is connected to a cloud containing AMF (Access and Mobility Management Function), SMF (Session Management Function), and UPF (User Plane Function). The diagram also shows a PON (Passive Optical Network) connected to an OLT (Optical Line Terminal) and a Private line connected to the OLT. The OLT is connected to the Access network. The diagram illustrates the use of WDM technology in the backhaul and midhaul networks. + +**Figure 1:** WDM-based back-haul and mid-haul + +As the number and bandwidth of 5G base stations continually increase, metro x-haul transport networks are increasingly facing challenges, such as capacity, cost, power consumption, etc. WDM technologies are utilized in the metro networks to transport mobile traffic, enterprise services, fixed line services, etc., and WDM links and networks perform as an underlying network for the back-haul and mid-haul networks, to extend the transmission distance, increase the bandwidth, and reduce the cost and power consumption, as illustrated in Figure 1 above. + +WDM technology is used in several scenarios in back-haul and mid-haul networks. For instance, WDM-based underlying layer is used for the core rings in the metro, to extend the transmission distance and capacity. Also, WDM-based underlying layer is used for long-distance city-to-county connections, which could be with hundreds of kilometers. Furthermore, the interfaces of transport equipment are evolving, with high-rate WDM interfaces and coherent optics being increasingly used. + +With the application scenarios above, WDM technology is evolving towards technical directions, such as specific WDM interfaces and optical modules with high data rate and specific coherent optics, metro-optimized optical switching systems to reduce the latency for back-haul traffic, efficient protection, management and operation with specific WDM layer OAM, a coordination between underlying WDM layer and overlying back-haul packet layer, etc. + +# 3 Function Module of the (Fronthaul) Equipment + +When compared with 4G, 5G imposes higher requirements for transport networks in terms of bandwidth, latency, synchronization, reliability, and flexibility. As an important part of the transport network, the 5G fronthaul network shall meet these requirements and also address the difficulty of laying optical fibers to accommodate the exponential growth in 5G base stations. + +5G Radio Access Network (RAN) deployment has two scenarios: Distributed Radio Access Network (D-RAN) and Centralized Radio Access Network (C-RAN). C-RAN concentration usually needs pooled O-RAN Centralized Unit (O-CU) and Distributed Unit (O-DU) to support implementation. For the D-RAN scenario, O-RAN Radio Unit (O-RU) is deployed on the tower or rooftop or similar, while the O-DU is deployed below the tower or in another nearby building. + +The 5G fronthaul network mainly realizes the remote transmission of signals from O-RU to O-DU. C-RAN architecture puts forward new requirements for 5G fronthaul networks. WDM has become a solution for fronthaul networks. There are various WDM network architectures such as passive WDM, active WDM, and semi-active WDM. + +C-RAN fronthaul architecture can reduce the site rental fees, maintenance costs, and power consumption of O-DU in 5G greenfield and hotspot areas and has gained the favor of operators. In this chapter, several fronthaul schemes based on WDM technologies are briefly introduced. + +While 5G represents a major driver for the technologies presented in this document, they can also be applied to 4G fronthaul networks. For the sake of simplicity, this document only refers to 5G. + +## 3.1 Passive WDM + +The passive WDM solution is based on the end-to-end all-passive method without relay amplification and dispersion compensation to save the consumption of optical fiber resources. To achieve a low-cost WDM transmission, as shown in **Figure 2**, the O-RU directly uses the fixed or tunable optical transceivers, connected to the passive multiplexer/demultiplexer through the branch optical cable. At the O-DU side of the central office, the passive multiplexer/demultiplexer performs wavelength multiplexing/demultiplexing, which realizes the one-to-one optical wavelength connection. + +![Diagram of Passive WDM architecture showing O-RU and O-DU connected via a passive multiplexer/demultiplexer.](37da6628bdc4823e211405f1278acfb4_img.jpg) + +The diagram illustrates the Passive WDM architecture. On the left, labeled 'O-RU', there are three antenna icons, each connected to a small blue box representing an optical transceiver. These transceivers are connected via colored lines to a large, multi-colored trapezoidal block representing a passive multiplexer/demultiplexer. A single horizontal line connects this block to another identical multi-colored trapezoidal block on the right, representing the O-DU side. This second block is connected to a blue server rack icon, also representing an optical transceiver. The entire setup is labeled 'O-DU' at the top right. + +Diagram of Passive WDM architecture showing O-RU and O-DU connected via a passive multiplexer/demultiplexer. + +**Figure 2:** Passive WDM + +Because the equipment at the O-DU side is only with colored optical transceivers, disadvantages of passive WDM include lack of management channel, weak perception of fiber link fault, the difficulty of optical transceiver operation, and maintenance that depends on manual work. Basic management functions of optical channels, fiber link fault, and the optical transceiver can be achieved in O-RU and O-DU host systems. + +The equipment at the O-RU side and O-DU side may contain tunable optical transceivers, with active communication channels that exist within the optical carrier channel but do not affect the traffic. These transceivers allow the O-DU to exchange health, command, and control status information without the use of a supervisory channel. MSA (STM) specification for interoperable transceivers is part of a working group to allow O-RU and O-DU passive architectures to perform maintenance tasks. + +## 3.2 Active WDM + +The active WDM solution uses active WDM equipment for electrical and/or optical layer multiplexing at both the remote station and the central office, as shown in **Figure 3**. This solution also reduces the number of fibers and can provide management functions between WDM equipment. + +![Diagram of Active WDM architecture showing O-RU, WDM, and O-DU components.](2f744edebc59b0fc4b5a472d52bb9b9a_img.jpg) + +The diagram illustrates the Active WDM architecture. On the left, labeled 'O-RU', there are three antenna units, each connected to a WDM (Wavelength Division Multiplexing) block. These WDM blocks are connected to a central WDM block. A green and yellow optical link connects this central WDM block to another WDM block on the right, labeled 'O-DU'. This second WDM block is connected to a server rack representing the O-DU. + +Diagram of Active WDM architecture showing O-RU, WDM, and O-DU components. + +**Figure 3:** Active WDM + +Compared with the Passive WDM, the cost of the active WDM scheme is about 4-6 times higher, based on operator studies, and is not conducive to large-scale deployment of 5G fronthaul. Due to the remote location of WDM equipment at the O-RU side, available power sources and outdoor location may cause difficulty in the installation of this implementation. + +## 3.3 Semi-Active WDM + +With the accelerated deployment of 5G networks, the fronthaul network will have thousands of nodes creating a need for management of the capability of the network. + +The proposed semi-active WDM schemes are illustrated in **Figure 4**. + +![Figure 4: Semi-active WDM. The diagram shows two types of semi-active WDM architectures. Type I shows O-RU units connected to a passive WDM multiplexer, which is then connected to an O-DU unit. Type II shows O-RU units connected to a passive WDM multiplexer, which is then connected to an O-DU unit through an Active Equipment block containing a PD+MCU (Photodetector + Microcontroller Unit). The Active Equipment block is shown with arrows indicating data flow between the WDM and the PD+MCU, and between the PD+MCU and the O-DU.](769f6230a2e5ded1245b07d7424fa29d_img.jpg) + +1) Type I + +2) Type II + +Figure 4: Semi-active WDM. The diagram shows two types of semi-active WDM architectures. Type I shows O-RU units connected to a passive WDM multiplexer, which is then connected to an O-DU unit. Type II shows O-RU units connected to a passive WDM multiplexer, which is then connected to an O-DU unit through an Active Equipment block containing a PD+MCU (Photodetector + Microcontroller Unit). The Active Equipment block is shown with arrows indicating data flow between the WDM and the PD+MCU, and between the PD+MCU and the O-DU. + +**Figure 4:** Semi-active WDM + +This semi-active WDM solution is a simplification of the active WDM solution and an enhancement of the passive solution. Passive WDM at the remote O-RU side is not subject to power supply restrictions. The WDM equipment at the O-DU side of the central office is active, which can achieve monitoring, fault detection, and protection capabilities. + +The active WDM equipment can send management requests to the O-RU and manage the WDM optical modules within the O-RU, including query and configuration. The optical modules within the O-RU can receive management requests from the active WDM equipment and then send the OAM information of the optical modules to the active WDM equipment, including the wavelength and output power of the transmitter. The optical modules in the O-RU and the O-DU can send the OAM information of optical modules to the active WDM equipment automatically or at regular time intervals once the optical modules are powered on. The WDM optical modules can add the OAM information with the service signals and transport them together in the same optical channel. The detection unit in the active WDM equipment can demodulate the OAM information, obtain the transmission performance of O-RU and O-DU, and then report it to the control system through the standard southbound interface. The semi-active WDM type I equipment should support query, configuration, and send OAM information. To further reduce system cost, the semi-active WDM type II equipment can perform simplified management, including sending the OAM information of optical modules to the active WDM equipment. + +The semi-active WDM solution not only greatly reduces the pressure of optical fiber resources but also has cost advantages (compared with the active solution), management, and protection outside the optical transceiver and O-RU/O-DU host systems (compared with the passive solution). It helps operators to build 5G fronthaul networks with low cost, high bandwidth, and fast deployment. + +## 3.4 Phase 2 WDM Protection + +For the 5G fronthaul scenario, there are several WDM protection schemes, such as optical layer protection and electrical layer protection. + +There are two typical optical layer protection methods to protect the optical fiber link, including 1+1 and 1:1 optical protection. The architecture of 1+1 optical protection is shown in **Figure 4 (a)**, which is composed of a 3 dB splitter at the remote part and a 1\*2 optical switch at the local part. **Figure 4(b)** shows the architecture of 1:1 optical protection, which consists of two 1\*2 optical switches at both remote and local parts. + +![Figure 4(a): 1+1 optical protection architecture. This diagram shows the 1+1 optical protection scheme. On the left, the 'Remote part' contains an 'O-RU' connected to an 'Active WDM' block, which is then connected to a '3dB splitter'. The splitter has two outputs: a 'Work link' (green line) and a 'Protection Link' (red line). On the right, the 'Local part' contains a '1*2 switch' with two inputs corresponding to the Work and Protection links. The switch is controlled by an 'electric power supply' and is connected to an 'Active WDM' block, which is then connected to an 'O-DU'.](7bc652502bda3fe1196b0faae7b2d8ac_img.jpg) + +Figure 4(a): 1+1 optical protection architecture. This diagram shows the 1+1 optical protection scheme. On the left, the 'Remote part' contains an 'O-RU' connected to an 'Active WDM' block, which is then connected to a '3dB splitter'. The splitter has two outputs: a 'Work link' (green line) and a 'Protection Link' (red line). On the right, the 'Local part' contains a '1\*2 switch' with two inputs corresponding to the Work and Protection links. The switch is controlled by an 'electric power supply' and is connected to an 'Active WDM' block, which is then connected to an 'O-DU'. + +**Figure 4(a): 1+1 optical protection architecture** + +![Figure 4(b): 1:1 optical protection architecture. This diagram shows the 1:1 optical protection scheme. On the left, the 'Remote part' contains an 'O-RU' connected to an 'Active WDM' block, which is then connected to a '1*2 switch'. The switch is controlled by an 'electric power supply'. The switch has two outputs: a 'Work link' (green line) and a 'Protection Link' (red line). On the right, the 'Local part' contains another '1*2 switch' with two inputs corresponding to the Work and Protection links. This switch is also controlled by an 'electric power supply' and is connected to an 'Active WDM' block, which is then connected to an 'O-DU'.](890db1757fc1e53b51d29aef2bf3a43e_img.jpg) + +Figure 4(b): 1:1 optical protection architecture. This diagram shows the 1:1 optical protection scheme. On the left, the 'Remote part' contains an 'O-RU' connected to an 'Active WDM' block, which is then connected to a '1\*2 switch'. The switch is controlled by an 'electric power supply'. The switch has two outputs: a 'Work link' (green line) and a 'Protection Link' (red line). On the right, the 'Local part' contains another '1\*2 switch' with two inputs corresponding to the Work and Protection links. This switch is also controlled by an 'electric power supply' and is connected to an 'Active WDM' block, which is then connected to an 'O-DU'. + +**Figure 4(b): 1:1 optical protection architecture** + +The 1+1 optical protection can be applied for semi-active WDM system and Active WDM system, which could not be used in the passive WDM system due to the electrical power supply requirement for the 1\*2 switch at the local part. The 1:1 optical protection can only be applied for the Active WDM system, which could not be used in the semi-active WDM and passive WDM system due to the electrical power supply required for the two 1\*2 switches both at remote and local parts. + +The key requirements of optical layer protection are listed in **Table 1**. + +| | 1+1 optical protection technology | 1:1 optical protection technology | +|-----------------------------------------|---------------------------------------------|-----------------------------------| +| The insertion loss of remote part | 3.5 dB | 1.5 dB | +| The insertion loss of local part | 1.5 dB | 1.5 dB | +| The total insertion loss | 5 dB | 3 dB | +| The switching time | <50ms | | +| The accuracy of optical power detection | $\pm 0.5$ dB | | +| The operation temperature | $-5 \sim +50$ °C | | +| The functions | automatic switching, manual switching, etc. | | +| Application | Semi-active WDM system<br>Active WDM system | Active WDM system | + +**Table 1:** The key requirements of optical layer protection + +For both 1+1 and 1:1 optical protection, optical signals can transport from the work link to the protection link automatically by using optical power detectors in the local part of the optical protection system to monitor the receiving optical power both in the work link and protection link. The threshold value and automatically switching can be adjusted, such as the receiving optical power in the work link is lower than a certain value or the difference of receiving optical powers between the work link and protection link is lower than a certain value. Additionally, the switching from work link to protection link also can be achieved manually by using the management and control system of WDM equipment to send information to the optical layer protection system. + +The WDM protection function also can be performed in the electrical layer to protect WDM equipment or ports, such as SNCP protection. The WDM system should support electrical cross-connection. + +# 4 Wavelength Allocation + +For the 5G fronthaul based on WDM technologies, there are several competing spectral grids, such as MWDM and DWDM. + +## 4.1 MWDM Wavelength Allocation + +The nominal central wavelengths of 12-channels bi-directional MWDM are defined in **Table 2** + +| Channel No. | Nominal Central Wavelengths (nm) | Direction | | Used in Pairs | +|-------------|----------------------------------|--------------|--------------|---------------| +| | | O-RU to O-DU | O-DU to O-RU | | +| 1 | 1267.5 | - | √ | O-RU: 1274.5 | +| 2 | 1274.5 | √ | - | | + +| | | | | | +|----|--------|---|---|-----------------| +| | | | | O-DU:<br>1267.5 | +| 3 | 1287.5 | - | ✓ | O-RU:<br>1294.5 | +| 4 | 1294.5 | ✓ | - | O-DU:<br>1287.5 | +| 5 | 1307.5 | - | ✓ | O-RU:<br>1314.5 | +| 6 | 1314.5 | ✓ | - | O-DU:<br>1307.5 | +| 7 | 1327.5 | - | ✓ | O-RU:<br>1334.5 | +| 8 | 1334.5 | ✓ | - | O-DU:<br>1327.5 | +| 9 | 1347.5 | - | ✓ | O-RU:<br>1354.5 | +| 10 | 1354.5 | ✓ | - | O-DU:<br>1347.5 | +| 11 | 1367.5 | - | ✓ | O-RU:<br>1374.5 | +| 12 | 1374.5 | ✓ | - | O-DU:<br>1367.5 | + +**Table 2: Nominal central wavelengths of MWDM** + +For the 6-channels bi-directional MWDM application, the wavelengths from channel 1 to channel 6 are preferred. + +The central wavelength spacing of adjacent channels of MWDM transmitters is 7 nm or 13 nm. The central wavelength spacing between odd channels and the central wavelength spacing between even channels are both 20 nm, respectively. + +MWDM systems can satisfy the 10 km transmission or 15 dB optical power budget requirements with low-cost Directly Modulated Laser (DML) and P Type-Intrinsic-N type (PIN) chips. For transmission distances beyond 10 km, even up to 20 km, the optical power budget can be further achieved by using a higher performance solution, e.g. Avalanche Photo Diode (APD) receiver. + +The applicability for MWDM is that Coarse Wavelength Division Multiplexing (CWDM) (O/E-Band) spectrum has lower dispersion penalties than DWDM, reusing low-cost optical chips. Considering relatively low channel density per fiber, MWDM is suitable for 12 or 6-channel WDM applications in 5G fronthaul. + +## 4.2 DWDM Wavelength Allocation + +Bidirectional and Duplex C-Band DWDM wavelength allocation requirements are to follow the ITU 100GHz grid specified in ITU-T G.694.1 [1]. Wavelength range 1529.55 – 1560.61 nm provides 40 ITU channels 21-60 that can be allocated to support optical transmission (**Table 3**). Note: more wavelengths could be allocated. + +| ITU Channel<br>(#) | Frequency<br>(GHz) | Wavelength<br>(nm) | ITU Channel<br>(#) | Frequency<br>(GHz) | Wavelength<br>(nm) | +|--------------------|--------------------|--------------------|--------------------|--------------------|--------------------| +| 21 | 192100 | 1560.61 | 41 | 194100 | 1544.53 | +| 22 | 192200 | 1559.79 | 42 | 194200 | 1543.73 | +| 23 | 192300 | 1558.98 | 43 | 194300 | 1542.94 | +| 24 | 192400 | 1558.17 | 44 | 194400 | 1542.14 | +| 25 | 192500 | 1557.36 | 45 | 194500 | 1541.35 | +| 26 | 192600 | 1556.56 | 46 | 194600 | 1540.56 | +| 27 | 192700 | 1555.75 | 47 | 194700 | 1539.77 | +| 28 | 192800 | 1554.94 | 48 | 194800 | 1538.98 | +| 29 | 192900 | 1554.13 | 49 | 194900 | 1538.19 | +| 30 | 193000 | 1553.33 | 50 | 195000 | 1537.4 | +| 31 | 193100 | 1552.52 | 51 | 195100 | 1536.61 | +| 32 | 193200 | 1551.72 | 52 | 195200 | 1535.82 | +| 33 | 193300 | 1550.92 | 53 | 195300 | 1535.04 | +| 34 | 193400 | 1550.12 | 54 | 195400 | 1534.25 | +| 35 | 193500 | 1549.32 | 55 | 195500 | 1533.47 | +| 36 | 193600 | 1548.52 | 56 | 195600 | 1532.68 | +| 37 | 193700 | 1547.72 | 57 | 195700 | 1531.9 | +| 38 | 193800 | 1546.92 | 58 | 195800 | 1531.12 | +| 39 | 193900 | 1546.12 | 59 | 195900 | 1530.33 | +| 40 | 194000 | 1545.32 | 60 | 196000 | 1529.55 | + +**Table 3:** Nominal ITU-T G.694.1 for 100GHz 40 channel Plan + +One optional Bidirectional pluggable (**Figure 5**) shall use a single 100GHz wavelength with an approximate +/- 50GHz offset upstream and downstream laser signals into a single 100GHz channel. + +![Diagram of BiDi DWDM C-Band pluggable showing three 100GHz channels (1529.55nm, 1530.33nm, 1531.12nm) with 50GHz offsets, and a list of features: 1 λ per link, Up to 40 Links, C-Band ITU 100Ghz.](f95bfd1fdd9b60c7a3df79b8df67414f_img.jpg) + +The diagram illustrates a BiDi (Bidirectional) DWDM C-Band pluggable. It shows three 100GHz channels, each represented by a pair of arrows (one red, one green, one blue) indicating bidirectional flow. The central wavelength for each channel is 1529.55nm, 1530.33nm, and 1531.12nm respectively. Each channel is composed of two 50GHz sub-channels, totaling 100GHz per channel. Below the channels, three pluggable modules are shown. To the right, a list of features is provided: + +- 1 λ per link +- Up to 40 Links +- C-Band ITU 100Ghz + +Diagram of BiDi DWDM C-Band pluggable showing three 100GHz channels (1529.55nm, 1530.33nm, 1531.12nm) with 50GHz offsets, and a list of features: 1 λ per link, Up to 40 Links, C-Band ITU 100Ghz. + +**Figure 5:** DWDM C-Band Bi-Directional + +Another optional bidirectional pluggable (**Figure 6**) shall use a single 100GHz wavelength for upstream and a single 100GHz wavelength for downstream. + +![Figure 6: DWDM C-band Bi-Directional diagram. The diagram shows two optical paths: 'downstream' and 'upstream'. The downstream path consists of a series of trapezoidal blocks representing waveguides, with a 100GHz spacing indicated. The upstream path is a mirror image. Colored arrows (blue, orange, green, red, yellow, purple) represent different wavelengths. Below the waveguides, two optical components (likely mux/demux) are shown, with lines indicating the connection between the waveguides and the components.](78d159ef968e015c92aa5dbfe2dff566_img.jpg) + +Figure 6: DWDM C-band Bi-Directional diagram. The diagram shows two optical paths: 'downstream' and 'upstream'. The downstream path consists of a series of trapezoidal blocks representing waveguides, with a 100GHz spacing indicated. The upstream path is a mirror image. Colored arrows (blue, orange, green, red, yellow, purple) represent different wavelengths. Below the waveguides, two optical components (likely mux/demux) are shown, with lines indicating the connection between the waveguides and the components. + +**Figure. 6** DWDM C-band Bi-Directional + +Wavelength allocation of bi-directional example is shown in **Table 4**, which is specified in Recommendation ITU-T G.698.4. + +| wavelength pairs (#) | frequency (THz) | wavelength (nm) | frequency (THz) | wavelength (nm) | +|----------------------|-----------------|-----------------|-----------------|-----------------| +| 1 | 196.00 | 1529.55 | 193.40 | 1550.12 | +| 2 | 195.90 | 1530.33 | 193.30 | 1550.92 | +| 3 | 195.80 | 1531.12 | 193.20 | 1551.72 | +| 4 | 195.70 | 1531.9 | 193.10 | 1552.52 | +| 5 | 195.60 | 1532.68 | 193.00 | 1553.33 | +| 6 | 195.50 | 1533.47 | 192.90 | 1554.13 | +| 7 | 195.40 | 1534.25 | 192.80 | 1554.94 | +| 8 | 195.30 | 1535.04 | 192.70 | 1555.75 | +| 9 | 195.20 | 1535.82 | 192.60 | 1556.55 | +| 10 | 195.10 | 1536.61 | 192.50 | 1557.36 | +| 11 | 195.00 | 1537.4 | 192.40 | 1558.17 | +| 12 | 194.90 | 1538.19 | 192.30 | 1558.98 | +| 13 | 194.80 | 1538.98 | 192.20 | 1559.79 | +| 14 | 194.70 | 1539.77 | 192.10 | 1560.61 | +| 15 | 194.60 | 1540.56 | 192.00 | 1561.42 | +| 16 | 194.50 | 1541.35 | 191.90 | 1562.23 | +| 17 | 194.40 | 1542.14 | 191.80 | 1563.05 | +| 18 | 194.30 | 1542.94 | 191.70 | 1563.86 | +| 19 | 194.20 | 1543.73 | 191.60 | 1564.68 | +| 20 | 194.10 | 1544.53 | 191.50 | 1565.50 | + +**Table 4:** Wavelength Plan for Bi-directional + +Duplex pluggable (**Figure 7**) shall use a single 100GHz wavelength for upstream and a single 100GHz wavelength for downstream to leverage a single passive mux/demux. + +![Figure 7: DWDM C-Band Duplex diagram showing four channels (1529.55nm, 1530.33nm, 1531.12nm, 1531.90nm) with 100GHz spacing, connected to two pluggable modules. The diagram is labeled 'Duplex' and includes a list of features: 2 λs per link, Up to 20 channels, and C-Band ITU 100GHz.](b8a10d74cce8c0b450445cf52faf78e1_img.jpg) + +**Duplex** + +- 2 $\lambda$ s per link +- Up to 20 channels +- C-Band ITU 100GHz + +Figure 7: DWDM C-Band Duplex diagram showing four channels (1529.55nm, 1530.33nm, 1531.12nm, 1531.90nm) with 100GHz spacing, connected to two pluggable modules. The diagram is labeled 'Duplex' and includes a list of features: 2 λs per link, Up to 20 channels, and C-Band ITU 100GHz. + +**Figure 7:** DWDM C-Band Duplex + +Another duplex pluggable, **Figure 8** shall use a single 100GHz wavelength for upstream and a single 100GHz wavelength for downstream to leverage a single passive mux/demux. + +![Figure 8: DWDM C-Band Duplex diagram showing a downstream section with multiple 100GHz channels (1529.55nm, 1530.33nm, 1531.12nm, 1531.90nm) and an upstream section with multiple 100GHz channels (1550.12nm, 1550.94nm, 1551.76nm, 1552.58nm). The diagram is labeled 'downstream' and 'upstream' and shows connections to two pluggable modules.](050453256732154319e894d3ca2c8525_img.jpg) + +**downstream**                      **upstream** + +100GHz                      100GHz + +1529.55nm                      1550.12nm + +Figure 8: DWDM C-Band Duplex diagram showing a downstream section with multiple 100GHz channels (1529.55nm, 1530.33nm, 1531.12nm, 1531.90nm) and an upstream section with multiple 100GHz channels (1550.12nm, 1550.94nm, 1551.76nm, 1552.58nm). The diagram is labeled 'downstream' and 'upstream' and shows connections to two pluggable modules. + +**Figure 8:** DWDM C-Band Duplex + +DWDM C-Band spectrum has higher dispersion penalties than CWDM but has higher channel densities for improved spectral efficiencies per fiber. + +# --- 5 Optical Equipment Technical Requirements + +This chapter gives the basic technical requirements for the key optical equipment or modules, such as optical transceivers and optical multiplexers, and demultiplexers. The fronthaul transport systems should support transport capacity with 3ch x 25 Gbps, 6ch x 25 Gbps, et.al, and the fiber reach with link budget listed in **Annex A**. + +## 5.1 Optical Transceiver Technical Requirements + +For 4G/5G fronthaul, the optical interfaces are based on the CPRI and eCPRI protocols, and have the following basic features: + +- Low Power Consumption +- Small Size with LC Optical Fiber Connector Receptacles +- Wide Temperature Range +- SFF-8472 Compliant + +If required, some functions such as wavelength tuning, out-of-band communication will be integrated. + +### 5.1.1 MWDM + +The optical parameters of the 25G MWDM optical transceiver are shown in **Table 5**. + +| Parameters | | Units | Proposed values | +|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------|-------|----------------------------------------------------------------------------------| +| Target fiber reach | | km | 10 | +| Fiber type | | - | G.652.D | +| Maximum Pre-FEC bit-error ratio | | - | $5 \times 10^{-5}$ | +| Optical parameters of the transmitter | | | | +| Transmitter central wavelength | O-RU side | nm | 1274.5; 1294.5; 1314.5;<br>1334.5; 1354.5; 1374.5 | +| | O-DU side | | 1267.5; 1287.5; 1307.5;<br>1327.5; 1347.5; 1367.5 | +| Maximum shift of central wavelength | | nm | $\pm 2.5$ | +| Maximum spectral bandwidth (-20 dB) | | nm | 1.0 | +| Average output power | | dBm | 2.0 ~ 7.0 | +| Minimum output power@ Optical Modulation Amplitude (OMA) | | dBm | 1.0 | +| Maximum Transmitter and Dispersion Penalty (TDP) | | dB | 1267.5 nm~ 1314.5nm: 1.0<br>1327.5nm ~ 1334.5nm: 3.0<br>1347.5 nm~ 1374.5nm: 4.5 | +| Minimum extinction ratio | | dB | 3.5 | +| Optical parameters of the receiver | | | | +| Receive wavelength range | | nm | 1260.0 ~ 1620.0 | +| Minimum receiver overload <sup>1</sup> | | dBm | PIN: +2.0<br>APD: -4.0 | +| Maximum receiver sensitivity <sup>2</sup> | | dBm | PIN: -13.0<br>APD: -18.0 | +| Maximum receiver sensitivity@OMA <sup>b</sup> | | dBm | PIN: -14.0<br>APD: -19.0 | +| 1. The receiver should tolerate the continuous injection of the average optical power without damage.<br>2. The receiver sensitivity includes the penalty of OAM modulation. | | | | + +**Table 5:** Optical parameters of 25 Gbps MWDM optical transceiver + +MWDM optical transceiver can be performed by designing MWDM DML laser or wavelength shifting from CWDM DML laser based on Thermo Electric Cooler (TEC). In the wavelength shifting scheme, according to the absolute value of the wavelength difference between the central wavelength of the optical transmitter and the central wavelengths of MWDM channels, specified in **Table 5**, the central wavelength of the optical transmitter should be adjusted to that of the nearest channel by modifying the TEC temperature. + +APD receiver is used for 10 km transmission with optical line protection or beyond 10 km transmission with the same optical power budget. + +The operating conditions of the 25 Gbps MWDM optical transceiver are shown in **Table 6**. + +| Parameter | | Min. | Max. | Unit | +|----------------------------|------------------|------|------|------| +| Operating Case Temperature | Commercial Grade | 0 | 70 | °C | +| | Industrial Grade | -40 | +85 | °C | +| Power consumption | | | 2.0 | W | + +**Table 6:** Operation conditions of 25 Gbps MWDM optical transceiver + +Industrial grade and commercial grade are required for MWDM optical transceivers applied in an outdoor and indoor scenario, respectively. + +### 5.1.2 DWDM + +For 4G/5G fronthaul, the optical interfaces are mainly based on the CPRI and eCPRI protocols, and have the following basic features (**Tables 7, 8, 9, 10**): + +- Power Consumption +- Temperature Specifications +- 10 Gbps BiDi Optical Transmitter Parameters +- 25 Gbps Duplex Optical Transmitter Parameters + +| Parameter | | Min. | Max. | Unit | +|----------------------------|------------------|------|------|------| +| Operating Case Temperature | Commercial Grade | 0 | 70 | °C | +| | Industrial Grade | -40 | +85 | °C | +| Power consumption | | | 2.5 | W | + +**Table 7:** Operation conditions of 10 Gbps and 25 Gbps DWDM transceiver + +#### 10G Duplex + +| Parameters | Units | Proposed values | Proposed values | Proposed values | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------|---------------------|---------------------|---------------------| +| Target fiber reach | km | 10 | 15 | 20 | +| Fiber type | - | G.652 | G.652 | G.652 | +| Maximum pre-FEC bit-error ratio | - | $1 \times 10^{-12}$ | $1 \times 10^{-12}$ | $1 \times 10^{-12}$ | +| Maximum Power Consumption | W | 2.5 | 2.5 | 2.5 | +| Transmitter | | | | | +| Transmitter data rate | Gb/s | 9.95 - 10.31 | 9.95 - 10.31 | 9.95 - 10.31 | +| Transmitter central wavelength | nm | 1529.55 -1560.61 | 1529.55 -1560.61 | 1529.55 -1560.61 | +| Transmitter Central Frequency | THz | 192.1 -196.0 | 192.1 -196.0 | 192.1 -196.0 | +| Channel Spacing | GHz | 100 | 100 | 100 | +| The maximum shift of center wavelength | nm | ITU $\pm$ 100 pm | ITU $\pm$ 100 pm | ITU $\pm$ 100 pm | +| Average output power | dBm | -1.0 +3.0 | -1.0 +3.0 | -1.0 +3.0 | +| Minimum extinction ratio | dB | 8.0 | 8.0 | 8.0 | +| | | | | | +| Receiver | | | | | +| Receiver Damage Threshold <sup>1</sup> | dBm | +3.0 | +3.0 | +3.0 | +| Maximum receiver input <sup>2</sup> | dBm | -7.0 | -7.0 | -7.0 | +| Maximum receiver sensitivity <sup>2</sup> | dBm | -18.0 | -19.0 | -19.5 | +| <p>1. The receiver shall be able to tolerate the continuous injection of the average optical power without damage.</p> <p>2. The receiver sensitivity includes the penalty of G.652 fiber at ER of 8.0 dB</p> | | | | | + +**Table 8:** 10 Gbps Duplex Optical Transmitter Parameters + +#### 10 Gbit/s BiDi + +| Parameters | Units | Proposed values | Proposed values | Proposed values | +|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------|-----------------------|-----------------------|-----------------------| +| Target fiber reach | km | 10 | 15 | 20 | +| Fiber type | - | G.652 | G.652 | G.652 | +| Maximum pre-FEC bit-error ratio | - | 1 x 10 <sup>-12</sup> | 1 x 10 <sup>-12</sup> | 1 x 10 <sup>-12</sup> | +| Maximum Power Consumption | W | 2.5 | 2.5 | 2.5 | +| Transmitter | | | | | +| Transmitter data rate | Gb/s | 9.95 – 10.31 | 9.95 – 10.31 | 9.95 – 10.31 | +| Transmitter central wavelength | nm | 1529.55 -1560.61 | 1529.55 -1560.61 | 1529.55 -1560.61 | +| Transmitter Central Frequency | THz | 192.1 -196.0 | 192.1 -196.0 | 192.1 -196.0 | +| Channel Spacing | GHz | 100 | 100 | 100 | +| The maximum shift of center wavelength | nm | ITU $\pm$ 40 pm | ITU $\pm$ 40 pm | ITU $\pm$ 40 pm | +| Average output power | dBm | +0.0 - +4.0 | +0.0 - +4.0 | +0.0 - +4.0 | +| Minimum extinction ratio | dB | 8.2 | 8.2 | 8.2 | +| Receiver | | | | | +| Receiver Damage Threshold <sup>1</sup> | dBm | +3.0 | +3.0 | +3.0 | +| Maximum receiver input <sup>2</sup> | dBm | -7.0 | -7.0 | -7.0 | +| Maximum receiver sensitivity <sup>2</sup> | dBm | -17.0 | -18.0 | -19.5 | +| 1. The receiver shall be able to tolerate the continuous injection of the average optical power without damage.<br>2. The receiver sensitivity includes the penalty of G.652 fiber at ER of 8.2 dB | | | | | + +**Table 9:** 10 Gbps BiDi Optical Transmitter Parameters + +#### 25 Gbps Duplex + +| Parameters | Units | Proposed values | Proposed values | +|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------|--------------------|--------------------| +| Target fiber reach | km | 10 | 15 | +| Fiber type | - | G.652 | G.652 | +| Maximum pre-FEC bit-error ratio | - | $5 \times 10^{-5}$ | $5 \times 10^{-5}$ | +| Maximum Power Consumption | W | 2.5 | 2.5 | +| <b>Transmitter</b> | | | | +| Transmitter data rate | Gb/s | 24.33 – 25.78 | 24.33 – 25.78 | +| Transmitter central wavelength | nm | 1529.55 -1560.61 | 1529.55 -1560.61 | +| Transmitter Central Frequency | THz | 192.1 -196.0 | 192.1 -196.0 | +| Channel Spacing | GHz | 100 | 100 | +| The maximum shift of center wavelength | nm | ITU $\pm$ 100 pm | ITU $\pm$ 100 pm | +| Average output power | dBm | 0.0 +3.0 | 0.0 +3.0 | +| Minimum extinction ratio | dB | 7.0 | 7.0 | +| <b>Receiver</b> | | | | +| Receiver Damage Threshold <sup>1</sup> | dBm | +3.0 | +3.0 | +| Maximum receiver input <sup>2</sup> | dBm | -7.0 | -7.0 | +| Maximum receiver sensitivity <sup>2</sup> | dBm | -17.0 | -18.0 | +| <p>1. The receiver shall be able to tolerate the continuous injection of the average optical power without damage.</p> <p>2. The receiver sensitivity includes the penalty of G.652 fiber at ER of 7.0 dB</p> | | | | + +**Table 10:** 25 Gbps Duplex Optical Transmitter Parameters + +The above recommendations for optical parameters apply to fixed wavelength and self/smart-tuning DWDM optical transceivers. For specifications specific to tunable and self/smart-tuning technologies please refer to the below references. + +- Self/Smart-Tuning Wavelength: [2] STM MSA: “Technical specification for Smart Tunable Modules + +### 5.1.3 Phase 2 DWDM Tuneable Use Cases + +In passive WDM, wavelength pairs self-tuning could be achieved through some mechanism (for example, the head end to tail end message channel(HTMC) and tail end to head-end message channel(THMC) specified in Recommendation ITU-T G.698.4) between the two tunable modules(TSFP28). And the tunable modules could be duplex or bi-directional using different Mux/Demux (**Figures 9 (a) and (b)**). + +![Figure 9 (a, b) Use Case of tunable DWDM in passive WDM.](64165b6fda77ddb7433e931fc3af26c9_img.jpg) + +Figure 9 (a, b) illustrates the use case of tunable DWDM in passive WDM. In both diagrams (a) and (b), an O-DU (blue block on the left) is connected to an O-RU (yellow block on the right) via a passive WDM system. The O-DU has three TSFP28 modules (red, yellow, green) and the O-RU has three TSFP28 modules (red, yellow, green). The WDM equipment consists of two multiplexer/demultiplexer prisms and a central fiber link with a green filter element in the middle. The connections between the modules and the prisms are shown as colored lines corresponding to the module colors. + +Figure 9 (a, b) Use Case of tunable DWDM in passive WDM. + +**Figure 9 (a, b)** Use Case of tunable DWDM in passive WDM. + +In semi-active DWDM (**Figure 10 (a) (b)**), the wavelength pairs could be self-tuned through some mechanism(for example, the head end to tail end message channel(HTMC) and tail end to head-end message channel(THMC) specified in Recommendation ITU-T G.698.4) between the WDM equipment and tunable module(TSFP28), and also be configured from the WDM equipment network controller. And the tunable modules could also be duplex or bi-directional using different Mux/Demux. + +![Figure 10 (a, b) Use Case of tunable DWDM in semi-active WDM.](be9cec6e16a8e660e292257af70652cb_img.jpg) + +Figure 10 (a, b) illustrates the use case of tunable DWDM in semi-active WDM. In both diagrams (a) and (b), an O-DU (blue block on the left) is connected to WDM equipment, which is then connected to an O-RU (yellow block on the right). The O-DU has three SFP28 modules. The WDM equipment has three SFP28 modules on the left side and three TSFP28 modules (red, yellow, green) on the right side. The O-RU has three TSFP28 modules (red, yellow, green). The WDM equipment consists of two multiplexer/demultiplexer prisms and a central fiber link with a green filter element in the middle. + +Figure 10 (a, b) Use Case of tunable DWDM in semi-active WDM. + +**Figures 10 (a,b)** Use Case of tunable DWDM in semi-active WDM. + +Active DWDM (**Figure 11 (a) (b)**), the wavelength pairs could be self-tuned through some mechanism (for example, the head end to tail end message channel(HTMC) and tail end to head-end message channel(THMC) specified in Recommendation ITU-T G.698.4) between the two WDM equipment, and also be configured from the WDM equipment network controller. And the tunable modules in WDM equipment could also be duplex or bi-directional using different Mux/Demux. + +![Figure 11: Use Case of tunable DWDM in active WDM. (a) shows O-DU connected to WDM equipment, which is connected to O-RU. (b) shows O-DU connected to WDM equipment, which is connected to O-RU. Both diagrams show SFP28 and TSFP28 ports on the O-DU and O-RU, and WDM equipment in the middle.](2f13584546a4e770ea62380988930e8f_img.jpg) + +Figure 11: Use Case of tunable DWDM in active WDM. (a) shows O-DU connected to WDM equipment, which is connected to O-RU. (b) shows O-DU connected to WDM equipment, which is connected to O-RU. Both diagrams show SFP28 and TSFP28 ports on the O-DU and O-RU, and WDM equipment in the middle. + +Figure11 (a and b) Use Case of tunable DWDM in active WDM. + +### 5.1.4 Phase 3 DWDM Smart-Tunable MSA + +<https://www.smarttunable-msa.org/> + +The SmartTunable MSA seeks to establish a standardization for self-tuning algorithms within wavelength tunable transceivers such that product from different vendors will interoperate and self-tune properly. Currently, multiple proprietary Self-Tuning Optic (STO) schemes are being implemented by various transceiver suppliers, however none of these will work appropriately with each other. This MSA provides a technical framework for allowing customers to multisource their wavelength tunable transceivers with compatible STO functions. + +### 5.1.5 Phase 4 DWDM SmartTunable MSA + +The SmartTunable MSA has gained interest by many operators (listed below). + +![ADVA logo](772fd1b3c0b0e6c4503e428b30847746_img.jpg) + +ADVA logo + +![AT&T logo](f5ebb1500382b31a296032b6cc633b3a_img.jpg) + +AT&T logo + +![ATOP logo](a144eae851ef56734d1cf505c4b60281_img.jpg) + +ATOP logo + +![ChemOptics logo](c0ad355d72c457db2044f8927b5ec0c6_img.jpg) + +ChemOptics logo + +![COHERENT logo](06c3ed14587bdbcd17c049ed26f09659_img.jpg) + +COHERENT logo + +![EFFECT PHOTONICS logo](579a54c9653962940ffe4bfd0853efcd_img.jpg) + +EFFECT PHOTONICS logo + +![HGGenuine logo](b3ebb28d2ead2be7e45b5b5bccb35892_img.jpg) + +HGGenuine logo + +![HUBER+SUHNER logo](3bed333618a7f55307c9375e85c73ff6_img.jpg) + +HUBER+SUHNER logo + +![LIGHTIRON logo](0e0b355935cc7b204a0a7667300d94ca_img.jpg) + +LIGHTIRON logo + +![Linktel TECHNOLOGIES logo](044606d87da1d09fbbc699aad677ac78_img.jpg) + +Linktel TECHNOLOGIES logo + +![LUMENTUM logo](186f4dc8e289708d7c5e6c23fd9ae5f2_img.jpg) + +LUMENTUM logo + +![Orchestrating a brighter world NEC logo](4f7a4667ae1b406aedf697e6f527a120_img.jpg) + +Orchestrating a brighter world NEC logo + +![OE SOLUTIONS logo](8f88304ab70b551d8926032c99b4217c_img.jpg) + +OE SOLUTIONS logo + +![OC OPTICORE logo](6b54d76e748b0d137dd01a3c6f53adcf_img.jpg) + +OC OPTICORE logo + +![SOLID logo](e9bdfe9ab6ae256f2fa2c6cb8ae02a0a_img.jpg) + +SOLID logo + +*Note: Nokia is in the process of joining the MSA.* + +The MSA has completed the interoperability specification for the 10Gbps optical transceivers. The following link is the specification (note: future revision will require going to the MSA site mentioned in section 4.1.4 to download the latest version.) + +#### SmartTunable MSA 10Gbps Specification + +<https://www.smarttunable-msa.org/wp-content/uploads/2022/03/Self-Tuning-Optics-Interoperability-V1p0.pdf> + +ORAN phase 4 document update communicates the above MSA spec as the recommendation to all self-tunable optical suppliers to comply with this spec to ensure vendor interoperability and standard tuning methodology. + +Ongoing work with the SmartTunable MSA focuses on 25Gbps optical transceivers targeted to complete in 2024. + +### 5.1.6 Phase 5 MOPA Updates + +Led by Stefan (Ericsson) + +This is a summary of the recent relevant work and results from MOPA (see technical papers 3.0 and 3.1: <https://mopa-alliance.org/papers-and-presentations/>): + +**Optical pluggable performance for tight synchronization:** This area has moved into a separate paper to provide more flexibility and also reduce the page count of the main paper. An additional stand-alone paper in the 3.1 release features “Implementation considerations about FEC and MII extenders for “tight sync””. This paper deals with the tight sync complexities related to new work in IEEE 802.3 regarding Ethernet frame manipulations, such as MII extenders and segmented FEC, which is particularly relevant for coherent modules. The paper reviews the associated risks and, referencing the ongoing standardization discourse, highlights some principles that can be used to manage such risks during device design, with the objective to enable (coherent) pluggable optics to meet the more stringent pluggable accuracy classes defined in the above-mentioned paper. + +**Coherent lite for mobile networks.** Also this area has been pulled out from the main paper into a separate paper. This work mainly investigates using coherent technologies (standardized in IEEE Std. 802.3-2022 100GBASE-ZR and ITU-T Recommendations G.709.2 / G.698.2, etc.) for CRAN DWDM blueprints extending to 100 Gbps per channel and beyond, which is effective in overcoming the chromatic dispersion limits of IM-DD systems (see below for long reach DWDM). Of particular focus is adopting coherent systems for bidirectional trunks, while still using the same laser for both Tx and local oscillator to keep the optical module power consumption reasonable for mobile equipment. The backscattering and reflections penalties are experimentally explored, and further work is outlined. + +**LWDM:** to address the need for fiber lean and cost-effective solutions, a new LWDM blueprint for 10 Gb/s and 25 Gb/s 15 km, suitable for CRAN, is introduced. Also 15 km for 100 Gbps has been investigated and seems doable. + +**Longer reach DWDM:** Drive by operator demand for long reach optical solutions for CRAN, solutions and alternatives for 30-40 km IM-DD DWDM has been investigated. Both C-band and O-band solutions have been included. While 10 Gbps solutions are relatively straightforward, plausible candidates for 25 Gbps include 40 km DWDM in C-band using advanced electronic dispersion compensation (EDC) where one of the main questions is the possibility of meeting the 2.5 W requirement for I-temp SFP28. + +**LLS optical link data rate auto-negotiations** is introduced with motivation and possible solutions are discussed on a high level. + +**Cloud RAN optics.** This area is introduced with a high-level description and summarized responses from a MOPA Operator Advisory Board questionnaire. The results point to strong operator interest for a range of blueprints including both DRAN and CRAN, with bidi, DWDM and packet aggregation technologies. Another result indicates that the data rate outlook is relatively short term. + +**Retimed and linear optics for 100 Gbps SFP112:** new work makes a high-level overview of retimed and linear implementations and summarizes responses from the MOPA members on SFP112 implementations. The results point to FR, LR, ER and bidi SFP112 being available in the next years primarily in re-times variants as the linear implementations so far seem fewer. + +### 5.1.7 Phase 5 Beyond 25G WDM + +Recently, ITU-T has consented and released two new recommendations for multichannel WDM applications with single-channel optical interfaces in the O-band, G.698.5 and G.698.6. Both recommendations define and provide values for optical interface parameters of point-to-point WDM applications on over a single fiber link at up to 25 Gbit/s per channel. G.698.5 defines a nominal optical channel frequency spacing of 800 GHz (leveraging LAN-WDM), while G.698.6 defines alternating channel wavelength spacing of 7 nm and 13 nm in the O-band, equivalent to the MWDM solution in this specification. These recommendations do not contain optical amplifiers. G.698.6 is now supporting line rates at 50 Gbit/s and 100 Gbit/s. ITU-T has also consented a ITU-T recommendation G.9802 about “Wavelength division multiplexed passive optical networks (WDM PON)” but with 25Gbit/s maximum line rate per wavelength carrier. + +However, as of today, WDM transceiver technology beyond 25 Gbit/s per channel is still under development or study. The industry has largely adopted PAM-4 modulation format for 50 Gbit/s and even 100 Gbit/s per lane. At such a high baud rate (i.e. higher than 25 GBd/s), chromatic dispersion penalty becomes more severe, and therefore, O-band or the wavelengths closer to the zero-dispersion window is used for transmission. Also, unlike the gray optics commonly used for intra-datacenter, the fronthaul needs at least two different wavelengths to enable bidirectional single-fiber working. In this regard, there are few industrial standards that might be leveraged: + +- IEEE 802.3cp (50GBASE-BR10/20/40) which is designed for BiDi transmission over specific reaches but only a single pair +- IEEE 802.3dk (100GBASE-BR) which is still under draft for up to 40km BiDi transmission at 100 Gbit/s +- 100G Lambda MSA which defines 100G PAM-4 optical signaling and encoding, FEC and link characteristics for 100G and 400G applications using 100Gb/s per optical channel for 2km and 10km reaches. + +These aforementioned specifications may also potentially adopt the LAN-WDM grids, or even tighter ones, but this will require further study on the respective link characteristics. ITUT G.9804 series (50G HS-PON) which offers another alternative point-to-multipoint access beyond 25G for x-haul transport. The TWDM favors (eg. based on NG-PON2) is also an option for 50G HS-PON with presently limited implementation. There are many ongoing research in this area, and this also remains for further study in this specification. + +On the other hand, with the huge success of coherent 400G transceiver adoption, the industry has already started evaluating and standardizing coherent 100G for optical access, including RAN transport. In this case, coherent technology enabled by merchant DSP chips and photonic integration has better performances in terms of reach and link budget. For instance, + +- IEEE 802.3ct (100GBASE-ZR) defines a coherent DP-DQPSK 100G per channel interface in the C-band DWDM grids over 80 km. The current commercial solutions offer also tunability, flexgrid, and even ZR+ reach (more than 80 km), in either QSFP28 or QSFP-DD form factor today. +- CableLabs Coherent PON (CPON) is an ongoing standardization to define a coherent 100G T(W)DM point-to-multipoint PON in the C-band, with 35 dB link budget for long reach and high splitting ratio, also potentially WDM stacking (i.e. multiple PONs over a single fiber strand). +- ITU-T Q2/SG15 G.VHSP is similarly also exploring coherent technologies for 200G PON, at the moment considering both IM-DD and coherent approaches. +- The Open XR Optics Forum is the multi-source agreement (MSA) working group for XR optics, this industry's forum dedicated to point-to-multipoint with coherent pluggable transceiver technology. + +It is not yet clear how these coherent optical access technologies can be adapted to the O-RAN x-haul transport, and it remains interesting for future considerations. + +## 5.2 Multiplexer / Demultiplexer Technical Requirements + +The xWDM multiplexer and demultiplexer modules based on free-space cascaded thin-film filters or array waveguide grating technology shall be entirely passive and have high-temperature stability over the entire operating temperature range. + +### 5.2.1 MWDM + +Cascaded Thin Film Filter (TFF) is applied for the MWDM multiplexer and demultiplexer at the O-RU side and the O-DU side. As the optical power budget including TDP between MWDM channels from 1260 nm to 1380 nm is quite different, the sequence of filters can be divided into several series or series-parallel groups, according to the power budget of each channel where the central wavelength of the filter is located, resulting in unequal paired insertion loss of filters in different groups and equal paired insertion loss of series filters in each group (shown in **Figure 12**). The total optical power budget of each MWDM channel based on unequal paired insertion loss scheme should be less than or equal to that of equal paired insertion loss scheme. The difference in optical power budget between MWDM channels should be less than 1 dB. + +![Figure 12: Cascaded TFF-based MWDM multiplexer and demultiplexer. The diagram shows a central fiber optic cable connected to two identical cascaded TFF-based MWDM multiplexer and demultiplexer structures. Each structure consists of a series of 12 filters (represented by ovals) connected by tributary interfaces (represented by squares). The filters are labeled with wavelengths: 1374.5, 1367.5, 1354.5, 1347.5, 1334.5, 1327.5, 1314.5, 1307.5, 1294.5, 1287.5, 1274.5, and 1267.5 nm. The central fiber optic cable is represented by a circle with a vertical line through it. The legend indicates: oval = filter, square = tributary interface, and line = line interface.](56d67cea5e4ef68d58932b36f0b7d13e_img.jpg) + +Figure 12: Cascaded TFF-based MWDM multiplexer and demultiplexer. The diagram shows a central fiber optic cable connected to two identical cascaded TFF-based MWDM multiplexer and demultiplexer structures. Each structure consists of a series of 12 filters (represented by ovals) connected by tributary interfaces (represented by squares). The filters are labeled with wavelengths: 1374.5, 1367.5, 1354.5, 1347.5, 1334.5, 1327.5, 1314.5, 1307.5, 1294.5, 1287.5, 1274.5, and 1267.5 nm. The central fiber optic cable is represented by a circle with a vertical line through it. The legend indicates: oval = filter, square = tributary interface, and line = line interface. + +**Figure 12:** Cascaded TFF-based MWDM multiplexer and demultiplexer + +The optical parameters of a 12-channel MWDM multiplexer and demultiplexer are shown in **Table 11**. The central wavelength spacing of MWDM channels for the multiplexer/demultiplexer is 10nm. The central wavelength of the bandwidth for the multiplexer/demultiplexer is 1.5 nm away from the central wavelength of the MWDM channel where the multiplexer/demultiplexer is located. + +| Parameters | | Unit | Proposed values | | | | | | | | | | | | +|--------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------|------|-----------------|--------|--------|--------|--------|--------|--------|--------|--------|--------|--------|--------| +| Central wavelength | | nm | 1267.5 | 1274.5 | 1287.5 | 1294.5 | 1307.5 | 1314.5 | 1327.5 | 1334.5 | 1347.5 | 1354.5 | 1367.5 | 1374.5 | +| The maximum shift of central wavelength | | nm | ± 1.2 | | | | | | | | | | | | +| 1 dB bandwidth | | nm | ≥ 5.0 | | | | | | | | | | | | +| Passband flatness <sup>a</sup> | | dB | ≤ 0.5 | | | | | | | | | | | | +| Maximum Insertion loss @ O-RU+O-DU pairs, including the IL of an optical splitter <sub>a</sub> | | dB | 6.1 | 6.1 | 6.1 | 6.1 | 6.1 | 6.1 | 4.5 | 4.5 | 3.0 | 3.0 | 3.0 | 3.0 | +| Maximum insertion loss @ O-RU side | | dB | 3.0 | 2.8 | 3.2 | 2.6 | 3.4 | 2.4 | 2.2 | 2.0 | 1.5 | 1.2 | 1.7 | 1.0 | +| Maximum insertion loss @ O-DU side | without the IL of an optical splitter | dB | 2.8 | 3.0 | 2.6 | 3.2 | 2.4 | 3.4 | 2.0 | 2.2 | 1.2 | 1.5 | 1.0 | 1.7 | +| | with the IL of an optical splitter | dB | 3.1 | 3.3 | 2.9 | 3.5 | 2.7 | 3.7 | 2.3 | 2.5 | 1.5 | 1.8 | 1.3 | 2.0 | +| a. For the scene of the multiplexer and demultiplexer integrated an optical splitter, the maximum additional flatness of the splitter is 0.4 dB. | | | | | | | | | | | | | | | + +**Table 11:** Optical parameters of 12-channels MWDM multiplexer and demultiplexer + +The multiplexer and demultiplexer shall support the LC fiber connectors. IP-65 requirements for waterproof and dustproof at the O-RU side should be satisfied. + +### 5.2.2 DWDM C-Band Example of a BiDi 40 Channel 100Ghz Mux/Demux + +The optical parameters of a 40-channel DWDM multiplexer and demultiplexer are shown in Table 10. The central wavelength spacing of DWDM channels for the multiplexer/demultiplexer is 0.08 nm. The use case for the BiDi 40 Channel 100GHz Mux/Demux is ideal to implement 10G DWDM Bidi optical transmitters and 25G Duplex optical transmitters (**Table 12**). + +| Parameter | | Specifications | Remark | +|------------------------------------------|---------|---------------------------|-------------------------| +| Channel Band | | DWDM 1529.55 ~ 1560.61 nm | 40 wavelengths | +| Channel Spacing | | 100 GHz | DWDM | +| Channel Passband | | ± 0.11 nm | DWDM | +| Insertion Loss | Typical | DWDM 4.6 dB | Connector loss Included | +| Pass Band Ripple | Max | 0.5 dB | | +| Adjacent Channel Isolation<br>D40AWG | Min | 30 dB | | +| Non-Adjacent Channel Isolation<br>D40AWG | Min | 45 dB | | +| Optical Return Loss | Min | 45 dB | | +| Directivity | Min | 50 dB | | +| Polarization Dependent Loss | Max | 0.2 dB | | +| Connector Type | | All port LC/UPC | | + +**Table 12:** 25 Gbps Duplex Optical Transmitter Parameters + +The tributaries of bi-directional multiplexer and demultiplexer could be a dual interface or bi-directional, examples are shown in **figure.13**. For dual interface multiplexer and demultiplexer (**figure13 (a)**), each tributary interface is unidirectional for a single wavelength. For bi-directional, it could be achieved by cyclic FSR (**figure13(b)**) or the band filters contained in the devices (**figure 13(c)**). + +![Figure 13: Examples of bi-directional DWDM multiplexer and demultiplexer. (a) Dual interface multiplexer and demultiplexer showing unidirectional interfaces for each wavelength. (b) Bi-directional multiplexer and demultiplexer using cyclic FSR. (c) Bi-directional multiplexer and demultiplexer using band filters.](dcff3919f3d431813acd0258d76c6a5c_img.jpg) + +Figure 13 consists of three diagrams labeled (a), (b), and (c), illustrating different bi-directional DWDM multiplexer and demultiplexer configurations. Each diagram shows a central optical component (represented by a trapezoidal prism) with multiple input/output ports on the left and a single output port on the right. (a) shows a dual interface configuration where each wavelength $\lambda_i$ has a dedicated unidirectional interface. (b) shows a bi-directional configuration using cyclic FSR, where each wavelength $\lambda_i$ and its corresponding $\lambda_i'$ share a common interface. (c) shows a bi-directional configuration using band filters, where each wavelength $\lambda_i$ and its corresponding $\lambda_i'$ share a common interface, and the filters are represented by small blue squares on the prism's surface. + +Figure 13: Examples of bi-directional DWDM multiplexer and demultiplexer. (a) Dual interface multiplexer and demultiplexer showing unidirectional interfaces for each wavelength. (b) Bi-directional multiplexer and demultiplexer using cyclic FSR. (c) Bi-directional multiplexer and demultiplexer using band filters. + +**Figure 13 (a, b, c):** Examples of bi-directional DWDM multiplexer and demultiplexer + +The multiplexer and demultiplexer shall support the LC fiber connectors. + +## 5.3 Phase 2 WDM >10 km link Budget 25G + +### 5.3.1 Phase 2 MWDM + +The optical parameters of the 25 Gbps 15 km MWDM optical transceiver are shown in **Table 13**. Here, APD is used for a higher optical power budget introduced by TDP and DML can still be used at low cost. For a 20 km application, the MWDM solution would be discussed, such as EML may be used to reduce TDP. + +| Parameters | | Units | Proposed values | +|-------------------------------------------------------------------------------------------------------|-----------|-------|-----------------------------------------------------------------------------------------------------------| +| Target fiber reach | | km | 15 | +| Fiber type | | - | G.652.D | +| Maximum Pre-FEC bit-error ratio | | - | $5 \times 10^{-5}$ | +| Optical parameters of the transmitter | | | | +| Transmitter central wavelength | O-RU side | nm | 1274.5; 1294.5; 1314.5;<br>1334.5; 1354.5; 1374.5 | +| | O-DU side | | 1267.5; 1287.5; 1307.5;<br>1327.5; 1347.5; 1367.5 | +| Maximum shift of central wavelength | | nm | $\pm 2.5$ | +| Maximum spectral bandwidth ( -20 dB) | | nm | 1.0 | +| Average output power | | dBm | 1267.5 nm~ 1314.5nm: 2.0 ~ 7.0<br>1327.5nm ~ 1374.5nm: 3.75~ 7.0 | +| Minimum output power@ Optical Modulation Amplitude (OMA) | | dBm | 1267.5 nm~ 1314.5nm: 1.0<br>1327.5nm ~ 1374.5nm: 2.75 | +| Maximum Transmitter and Dispersion Penalty (TDP) | | dB | 1267.5 nm~ 1314.5nm: 1.0<br>1327.5nm ~ 1334.5nm: 4.5<br>1347.5nm~1354.5nm:6.0<br>1367.5 nm~ 1374.5nm: 7.0 | +| Minimum extinction ratio | | dB | 3.5 | +| Optical parameters of the receiver | | | | +| Receive wavelength range | | nm | 1260.0 ~ 1620.0 | +| Minimum receiver overload <sup>a</sup> | | dBm | APD: -4.0 | +| Maximum receiver sensitivity <sup>b</sup> | | dBm | APD: -18.0 | +| Maximum receiver sensitivity@OMA <sup>b</sup> | | dBm | APD: -19.0 | +| a. The receiver should tolerate the continuous injection of the average optical power without damage. | | | | +| b. The receiver sensitivity includes the penalty of OAM modulation. | | | | + +**Table 13:** Optical parameters of 25 Gbps 15 km MWDM optical transceiver + +### 5.3.2 Phase 2 DWDM + +Phase 2 will address the following additional aspects of <10 km DWDM transmission in support of 5G RAN architectures. + +Phase 2 will focus on 25bps line rate DWDM optical transmission. Currently standards for 10Gbps optical transmission support >10 km (i.e. up to 80 km without regeneration. Latency budget is the limiting restriction to 15-20 km.) + +- DWDM Link Budget + - Dispersion Compensation + - Optical Losses + - Optical Launch Power + - Optical Receiver Power + - Spectrum/Channel plan + - Modulation + +![Figure 14: Dispersion distance by line rate. A line graph showing Distance (km) on the Y-axis (0.0 to 90.0) versus Bit Rate on the X-axis (10 Gbps, 25 Gbps, 40 Gbps, 100 Gbps). The curve shows that as the bit rate increases, the maximum distance for CD compensation decreases. A yellow shaded area labeled 'Area of study' is highlighted between 25 Gbps and 40 Gbps, covering distances from approximately 15 km to 35 km.](a50940799e538c86d1b58e13ef2f9d47_img.jpg) + +| Bit Rate (Gbps) | Distance (km) | +|-----------------|---------------| +| 10 | 80 | +| 25 | 15 | +| 40 | 10 | +| 100 | 5 | + +Figure 14: Dispersion distance by line rate. A line graph showing Distance (km) on the Y-axis (0.0 to 90.0) versus Bit Rate on the X-axis (10 Gbps, 25 Gbps, 40 Gbps, 100 Gbps). The curve shows that as the bit rate increases, the maximum distance for CD compensation decreases. A yellow shaded area labeled 'Area of study' is highlighted between 25 Gbps and 40 Gbps, covering distances from approximately 15 km to 35 km. + +**Figure 14:** Dispersion distance by line rate + +![Figure 15: Example of loss contributors. A block diagram of an optical link. From left to right: Optical Transceiver (TX), Passive MUX, a series of connectors (C), a Fiber Splice (S), a Fiber Patch Cord (FST), a series of connectors (C), three LGX (Lossy Gain Elements), a series of connectors (C), a Passive MUX, and an Optical Transceiver (RX). The link is divided into three sections: OSP (Optical Service Provider) for the first part, Intra Office Cable for the middle part, and a final section for the last part. Above the diagram, two green arrows indicate 'Fiber Propagation' (solid line) and 'Fiber Passives, Splices, Connections....' (dashed line).](ef23ace3221ee4132c5039b54e73a3da_img.jpg) + +Figure 15: Example of loss contributors. A block diagram of an optical link. From left to right: Optical Transceiver (TX), Passive MUX, a series of connectors (C), a Fiber Splice (S), a Fiber Patch Cord (FST), a series of connectors (C), three LGX (Lossy Gain Elements), a series of connectors (C), a Passive MUX, and an Optical Transceiver (RX). The link is divided into three sections: OSP (Optical Service Provider) for the first part, Intra Office Cable for the middle part, and a final section for the last part. Above the diagram, two green arrows indicate 'Fiber Propagation' (solid line) and 'Fiber Passives, Splices, Connections....' (dashed line). + +**Figure 15:** Example of loss contributors + +The optical link budget for DWDM over single-mode fiber (G.652). Here, the fiber loss is ~0.3 dB/km, the loss of each connector is ~0.5 dB, and the passive mux loss assumption. (**Table 14**) + +| Parameters | 10 km | 15 km | +|------------|--------|--------| +| fiber loss | 3.0 dB | 4.5 dB | + +| | | | +|-----------------------------------------------------|-------|---------| +| Connector loss (depending on<br>Interoffice wiring) | ~2 dB | ~2-3 db | +| Mux loss (<3.5 db per Mux for AWG) | 7 db | 7 db | + +**Table 14: Assumed DWDM loss over SMF** + +#### 25 Gbps Duplex + +Phase 1 link budget previously documented supports the increased distance to 15 km with a 17 db link budget as it pushes the limitation of chromatic dispersion penalties. The only required change is to increase the power consumption by 2.5W. (**Table 15 and 16**) + +| Parameter | | Min. | Max. | Unit | +|-------------------------------|------------------|------|------|------| +| Operating Case<br>Temperature | Commercial Grade | 0 | 70 | °C | +| | Industrial Grade | -40 | +85 | °C | +| Power consumption | | | 2.5 | W | + +**Table 15: Operation conditions of 25 Gbps DWDM transceiver** + +| Parameters | Units | Proposed values | +|-----------------------------------------------------------------------------------------------------------------|-------|--------------------| +| Target fiber reach | km | 15 | +| Fiber type | - | G.652 | +| Maximum pre-FEC bit-error ratio | - | $5 \times 10^{-5}$ | +| Maximum Power Consumption | W | 2.5 | +| Transmitter | | | +| Transmitter data rate | Gb/s | 24.33 – 25.78 | +| Transmitter central wavelength | nm | 1529.55 -1560.61 | +| Transmitter Central Frequency | THz | 192.1 -196.0 | +| Channel Spacing | GHz | 100 | +| The maximum shift of center wavelength | nm | ITU $\pm$ 100 pm | +| Average output power | dBm | 0.0 +3.0 | +| Minimum extinction ratio | dB | 7.0 | +| Receiver | | | +| Receiver Damage Threshold <sup>a</sup> | dBm | +3.0 | +| Maximum receiver input <sup>b</sup> | dBm | -7.0 | +| Maximum receiver sensitivity <sup>b</sup> | dBm | -17.8 | +| a. The receiver shall be able to tolerate the continuous injection of the average optical power without damage. | | | +| b. The receiver sensitivity includes the penalty of G.652 fiber at ER of 7.0 dB | | | + +**Table16: 25 Gbps Duplex Optical Transmitter Parameters** + +Duplex C-Band DWDM wavelength allocation requirements are to follow the ITU 100 GHz grid specified in ITU-T G.694.1 [1]. Wavelength range 1529.55 – 1560.61 nm provides 40 ITU channels 21-60 that can be allocated to support optical transmission (**Table 17**). + +| ITU Channel<br>(#) | Frequency<br>(GHz) | Wavelength<br>(nm) | ITU Channel<br>(#) | Frequency<br>(GHz) | Wavelength<br>(nm) | +|--------------------|--------------------|--------------------|--------------------|--------------------|--------------------| +| 21 | 192100 | 1560.61 | 41 | 194100 | 1544.53 | +| 22 | 192200 | 1559.79 | 42 | 194200 | 1543.73 | +| 23 | 192300 | 1558.98 | 43 | 194300 | 1542.94 | +| 24 | 192400 | 1558.17 | 44 | 194400 | 1542.14 | +| 25 | 192500 | 1557.36 | 45 | 194500 | 1541.35 | +| 26 | 192600 | 1556.56 | 46 | 194600 | 1540.56 | +| 27 | 192700 | 1555.75 | 47 | 194700 | 1539.77 | +| 28 | 192800 | 1554.94 | 48 | 194800 | 1538.98 | +| 29 | 192900 | 1554.13 | 49 | 194900 | 1538.19 | +| 30 | 193000 | 1553.33 | 50 | 195000 | 1537.4 | +| 31 | 193100 | 1552.52 | 51 | 195100 | 1536.61 | +| 32 | 193200 | 1551.72 | 52 | 195200 | 1535.82 | +| 33 | 193300 | 1550.92 | 53 | 195300 | 1535.04 | +| 34 | 193400 | 1550.12 | 54 | 195400 | 1534.25 | +| 35 | 193500 | 1549.32 | 55 | 195500 | 1533.47 | +| 36 | 193600 | 1548.52 | 56 | 195600 | 1532.68 | +| 37 | 193700 | 1547.72 | 57 | 195700 | 1531.9 | +| 38 | 193800 | 1546.92 | 58 | 195800 | 1531.12 | +| 39 | 193900 | 1546.12 | 59 | 195900 | 1530.33 | +| 40 | 194000 | 1545.32 | 60 | 196000 | 1529.55 | + +**Table 17:** Nominal ITU-T G.694.1 for 100Ghz 40 channel Plan + +![Figure 16: A graph showing Attenuation (dB/km) and Dispersion (ps/km/nm) versus Wavelength (nm). The graph compares Conventional Fiber (G.652 A&B) and Low-Water-Peak Fiber (G.652 C&D). The x-axis ranges from 1271 nm to 1611 nm. The left y-axis is Attenuation (dB/km) from 0 to 1.0. The right y-axis is Dispersion (ps/km/nm) from -5 to 20. The Conventional Fiber curve shows a sharp peak in attenuation around 1380 nm and a sharp dip in dispersion around 1380 nm. The Low-Water-Peak Fiber curve shows a much flatter attenuation profile and a much flatter dispersion profile.](ab00edbcf5418abdea6fa92c4e3b3498_img.jpg) + +Figure 16: A graph showing Attenuation (dB/km) and Dispersion (ps/km/nm) versus Wavelength (nm). The graph compares Conventional Fiber (G.652 A&B) and Low-Water-Peak Fiber (G.652 C&D). The x-axis ranges from 1271 nm to 1611 nm. The left y-axis is Attenuation (dB/km) from 0 to 1.0. The right y-axis is Dispersion (ps/km/nm) from -5 to 20. The Conventional Fiber curve shows a sharp peak in attenuation around 1380 nm and a sharp dip in dispersion around 1380 nm. The Low-Water-Peak Fiber curve shows a much flatter attenuation profile and a much flatter dispersion profile. + +**Figure 16:** Example of attenuation and dispersion by wavelength + +It is worth noting that with some recent product development, both electrical dispersion compensation (EDC) and higher-order modulation (e.g. PAM-4) are able to extend the transmission reach to 20-40km. The former equalizes the electrical signal in the digital signal processing (DSP), while the latter reduces the effective baud rate to mitigate the dispersion penalty. The detailed link characteristics for interoperability are under further study. + +## 5.4 Phase 2 Optical Power Consumption + +Phase 2 will address the following additional aspects of optical transmitter power consumption in support of 5G RAN hardware components (i.e. TRP, DU...). + +- Thermal requirement +- Thermo Electric Cooler (TEC) +- Optical Transceiver function (Disp. Comp, Tuning....) +- Line Rate +- Form Factor + +Based on the current thermal requirements the following power consumption still stands as the max recommended target for SFP28 and QSFP28 optical transceivers. This power consumption supports WDM wavelengths covered across CWDM and DWDM solutions and typical optical features for <15 km use cases. The recommendation ensures peak power consumption during a -40°C cold start. **Table 18** + +| Parameter | Min. | Max. | Unit | +|-------------------|------|------|------| +| Commercial Grade | 0 | 70 | °C | +| Industrial Grade | -40 | +85 | °C | +| Power consumption | | 2.5 | W | + +**Table 18:** Thermal Requirements + +## 5.5 Phase 2 Optical Interfaces + +The purpose of this section is to summarize optical pluggable variants that support the Xhaul needs. **Table 19** below describes the variants. + +| Form factor | Data rate (Gb/s) | Max power (W) | Operating temp (°C) | Standard | +|---------------|------------------|---------------|---------------------|-------------| +| SFP | 1.25 | 1.5 | I-temp | SFF MSA | +| XSFP | 16 | 3.5 | C-temp | SFF MSA | +| SFP+ | 14 | 2 | I-temp | SFF MSA | +| SFP28 | 28 | 2.5 | I-temp | SFF MSA | +| SFP-DD/SFP-56 | 100 | 2.5 | C-temp | | +| QSFP+ | 40 | 3.5 | E-temp | SFF MSA | +| QSFP28 | 100 | 4.5 | E-temp | SFF MSA | +| QSFP-DD | 400 | 12 | C-temp | QSFP-DD MSA | + +**Table 19:** Optical pluggable variants + +Form formats of transceiver that are expected to be supported by O-RU: + +- SFP+ +- SFP28 +- 40G QSFP+ +- QSFP28 (50Gbps) + +However, today the bidirectional pluggable interface is only available for up to 25 Gbit/s. 50 Gbit/s is for further study at ITU-T Q.2/SG15. There is no working item for 100 Gbit/s at IEEE nor ITU-T. + +Regarding variable QSFP form factors, **Table 20** below lists the respective specifications. + +| Variant | Fiber type | Wavelength | Reach | | +|---------|------------|--------------|-------|--| +| DRx | MPO SMF | | 500 m | | +| FRx | Duplex SMF | | 2 km | | +| LR4 | Duplex SMF | 1295-1310 nm | 10 km | | +| ER4 | Duplex SMF | 1295-1310 nm | 40 km | | +| ZR | Duplex SMF | O- or C-band | 80 km | | +| PSM4 | MPO SMF | 1295-1325 nm | 500 m | | +| CWDM4 | Duplex SMF | 1270-1330 nm | 2 km | | +| 4WDM10 | Duplex SMF | 1270-1330 nm | 10 km | | +| 4WDM20 | Duplex SMF | 1295-1310 nm | 20 km | | +| 4WDM40 | Duplex SMF | 1295-1310 nm | 40 km | | + +**Table 20:** QSFP form factors + +### 5.5.1 Phase 2 Single and Duplex fiber solutions + +Passive WDM based on MWDM, CWDM, and DWDM grid for 1G, 10G, and 25G can be deployed in the following single and duplex fiber solutions, which can be applied to active, semi-active, or passive WDM systems. **(Figure 17-1,2,3)** + +#### 1. Duplex fiber + +The transceivers used in such a solution have the duplex fiber interface, and de- and mux filters are connected with duplex fiber strands for up- and downstream. Commonly up- and downstream use the same optical wavelength. + +![Figure 17-1: Duplex fiber working with duplex transceivers. This diagram illustrates a network architecture where an O-DU (Open Distributed Unit) is connected to multiple O-RUs (Open Radio Units) via duplex fiber and duplex transceivers. The O-DU is on the left, connected to a series of 'Plug' blocks. These 'Plug' blocks are connected to a central fiber network represented by a trapezoid. This central network is then connected to another set of 'Plug' blocks, which are in turn connected to multiple O-RUs on the right. The connections are bidirectional, as indicated by the arrows on the fiber links.](f35cde62508395a0d637afc0148ded4b_img.jpg) + +Figure 17-1: Duplex fiber working with duplex transceivers. This diagram illustrates a network architecture where an O-DU (Open Distributed Unit) is connected to multiple O-RUs (Open Radio Units) via duplex fiber and duplex transceivers. The O-DU is on the left, connected to a series of 'Plug' blocks. These 'Plug' blocks are connected to a central fiber network represented by a trapezoid. This central network is then connected to another set of 'Plug' blocks, which are in turn connected to multiple O-RUs on the right. The connections are bidirectional, as indicated by the arrows on the fiber links. + +**Figure 17-1:** Duplex fiber working with duplex transceivers + +#### 2. Single trunk fiber + +The transceivers used in such a solution have the duplex fiber interface, but de- and mux filters are connected with a single fiber strand for up- and downstream. Commonly up- and downstream use two separated wavelength sub-bands, but interleaving odd and even wavelength channels for up- and downstream is also possible. + +![Figure 17-2: Single fiber working with duplex transceivers. This diagram shows a similar network architecture to Figure 17-1, but with a single fiber strand used for both up- and downstream communication. The O-DU is on the left, connected to 'Plug' blocks, which are connected to a central fiber network (trapezoid). This network is then connected to another set of 'Plug' blocks, which are connected to multiple O-RUs on the right. The connections are bidirectional, as indicated by the arrows on the fiber links.](e2b94d6f73bb689060b4109d9c8b193b_img.jpg) + +Figure 17-2: Single fiber working with duplex transceivers. This diagram shows a similar network architecture to Figure 17-1, but with a single fiber strand used for both up- and downstream communication. The O-DU is on the left, connected to 'Plug' blocks, which are connected to a central fiber network (trapezoid). This network is then connected to another set of 'Plug' blocks, which are connected to multiple O-RUs on the right. The connections are bidirectional, as indicated by the arrows on the fiber links. + +**Figure 17-2:** Single fiber working with duplex transceivers + +#### 3. Bidi-fiber + +The transceivers used in such a solution have the simplex fiber interface (BiDi), and de- and mux filters are also connected with a single fiber strand for up- and downstream. + +![Figure 17-3: Single fiber working with BiDi transceivers. The diagram shows a central WDM de-mux/mux filter connected to O-DU and O-RU units via BiDi transceivers. The O-DU unit on the left has multiple 'Plug' blocks connected to a transceiver. The O-RU units on the right also have 'Plug' blocks connected to transceivers. A single fiber line connects the central filter to the transceivers on both sides. Below the central filter, there are two O-RU units, each with a 'Plug' block connected to the filter.](92650750ae5925b274f05db95ce5880f_img.jpg) + +Figure 17-3: Single fiber working with BiDi transceivers. The diagram shows a central WDM de-mux/mux filter connected to O-DU and O-RU units via BiDi transceivers. The O-DU unit on the left has multiple 'Plug' blocks connected to a transceiver. The O-RU units on the right also have 'Plug' blocks connected to transceivers. A single fiber line connects the central filter to the transceivers on both sides. Below the central filter, there are two O-RU units, each with a 'Plug' block connected to the filter. + +**Figure 17-3:** Single fiber working with BiDi transceivers + +Note: each filter port of the WDM de- and mux passes both up and downstream wavelength. In case the pluggable does not support the bidi interface, it is possible to use a patch cord diplexer to couple both transmitter and receiver connectors to a single distribution fiber, to be connected to the WDM de-/mux filter. + +### 5.6.0 Phase 3 Optical Link Budget + +### 5.6.1 Phase 3 MWDM Link Budget + +The link budget of MWDM for 10-km, 15-km, 20-km are shown in Table 21. In this way, DML-based MWDM can satisfy 15km application with low-cost for majority scenario and EML-based MWDM can satisfy 20km application with more cost. Use cases can be seen in Appendix A. + +| Distance | 10km | 15km | 20km | +|-------------|-------|----------|-------| +| Link Budget | 15 dB | 21.75 dB | 21 dB | + +**Table 21:** MWDM Link Budget + +### 5.6.2 Phase 3 DWDM Link Budget + +Current available tunable and fixed wavelength pluggable optics allow up to a 15km reach at 25Gb/s using NRZ modulation. In order to extend this reach to 20km or more, advance modulation techniques or a different technology needs to be employed. + +For instance, PAM-4 modulation can be used to keep the native data rate to 12.5Gbd to allow reaches at 40km or more. This can be achieved by using a linear laser driver on the transmit side and linear TIA on the receive side. However, this would require that the host and remote equipment contain the necessary ICs to encode and decode the PAM-4 modulation. + +Another potential solution would be to jump right to 100Gb/s using a low cost Coherent pluggable (such as a QSFP28-DCO). This product would fit directly into available QSFP sockets and could transmit over several hundred km (with + +amplification). The downside to this approach is that the power consumption would be $\sim 5\text{W}$ and the cost would be 2x-3x the cost of DWDM 25Gb/s optics. + +# 6 System Function and Performance Requirements + +## 6.1 Latency and jitter + +The one-way frame latency values in this sub-section were previously discussed in the "Xhaul Transport Requirements" document section 7.2 Table 3. For legacy Fronthaul, we propose to consider the Next Generation Mobile Networks (NGMN) Alliance document "FRONTHAUL REQUIREMENTS FOR C-RAN", 31 March 2015, version 1.0. + +A sub-section about latency asymmetry is not included in the "Xhaul Transport Requirements" of O-RAN WG9. The following specifications are derived from this document. + +Latency asymmetry between the downlink and uplink fronthaul will exist. This latency asymmetry could be caused by: + +- difference of optical fiber lengths when uplink and downlink use separate fibers (i.e. 7 m of ITU-T G.652 single-mode fiber approximately corresponds to a 34 ns delay) +- difference of wavelength propagation times when wavelengths are not similar for uplink and downlink (typically 1.3 $\mu\text{m}$ and 1.55 $\mu\text{m}$ wavelength diplex causes a $\sim 33$ ns time difference over 20 km of standard single-mode fiber ITU-T G.652). In particular, in the case of an ITU-T G.652 compliant fiber, the group delay at the applicable wavelengths can be calculated making use of the Sellmeier equations as described in [b-ITU-T G.652]. +- difference of processing time (including functions such as time multiplexing, encapsulation, compression, and Forward Error Correction (FEC)) at the Transport Network Equipment (TNE). + +Other transport functions could contribute to latency asymmetry. We propose to consider fronthaul latency asymmetry with and without positioning service based on time measurement. (**Table 21**) + +| | | +|----------------------------------------------------|--------------------------------------------------------------------------------------------------------------| +| Network latency asymmetry up & down-link fronthaul | 4G & 5G without radio positioning based on time measurement | +| Legacy fronthaul (CPRI) | O-DU could compensate this asymmetry for known value in the margin of +/- 10 000 ns | +| O-RAN fronthaul | O-RAN WG4 proposes absolute and relative time error margin to fiber asymmetry in annex H of WG4.CUS.0-v03.00 | + +**Table 21:** Network latency asymmetry up & down-link fronthaul without radio positioning + +We have also to consider mobile positioning. Positioning technologies for mobile devices become even more important for future connected digital applications in production, logistics, security, emergency services, and vehicular use cases. 5G and 6G should enable, and improve if suitable, state-of-art positioning techniques that are embedded or not in Radio Access Network systems (RAN-embedded and RAN-external respectively). + +For 5G, the impact of mobile positioning is defined in a different 3GPP release: + +- Rel15: No localization for 5G stand alone. In non-stand-alone (4G&5G), 4G localization is used based on the existing Time Difference of the Arrival method +- Rel16 (June 2021): 5G stand-alone with localization based on OTDOA and UTDOA\* with required precision: + - Localization <0.5 m (<2,5 ns) + - Speed: <500ms +- Rel17 (Sept 2021) more stringent requirement for localization + - <1 m (<5 ns) form mass market + - <0.2 m (<1 ns) for Industrial IoT (speed < 10ms) + +In this WDM Xhaul specification, we have focused our interest on RAN-embedded technologies with techniques based on Cell-ID, Enhanced Cell-ID, downlink angle of departure, uplink angle of arrival, multi-cell round trip time, and down- & up-link time difference of arrival. Positioning techniques based on time difference are the most common solutions and embedded the difference of time-delays in the fronthaul interface. + +The downlink time-based positioning techniques of User Equipment (UE) devices take advantage of the timing difference between several neighbors Digital Units (DU) and the UE to calculate the distance by estimating the Time Of Arrival (TOA) or Time Difference Of Arrival (TDOA) of specific radio signals. The Positioning Reference Signals (PRS) are initialized by the Radio Resource Control (RRC) layer at the CU concerning the associated DU where time stamping is achieved. The UE measures with multiple iterations the Reference Signal Time Difference (RSTD) between a pair of CUs and DUs corresponding to these PRS. In other words, RSTD corresponds to the difference of flight time between two cell sites (CU&DU) for the UE. The PRS crosses the mid-haul and fronthaul segments, the RU itself, and the air segment before reaching the UE. + +For 5G and 6G fronthaul supports P2P/SyncE to achieve phase/time synchronization at RU. In this case, a one-way measurement is possible because DU and RU are synchronized with a relative Time Error (TE) with Primary Reference Time Clock (PRTC). The fronthaul asymmetry is considered part of the contribution to the TE that must be below the required RSTD resolution. Three points must be noted: the fronthaul measurement is performed by the Control-Plane, the synchronization has its dedicated Sync-Plane, and finally, the PRS is embedded in the radio resource element map in the User-Plane. Due to these different references at different levels, the time of the fronthaul measurement and PRS transmission could differ. **(Table 22)** + +| Unit (ns) | 4G | 5G FR1 | 5G FR2 | +|-----------------|-----------|------------|-----------| +| Ts | 32.6 | 8.1 | 2 | +| RSTD resolution | 32.6 | 8.1 | 2 | +| RSTD accuracy | $\pm 130$ | $\pm 32.6$ | $\pm 8,1$ | + +**Table 22:** RSTD timing values standardized for 4G and calculated for 5G + +For 5G fronthaul, the relative and absolute fiber asymmetry is defined below the required RU TE (based on Sync. plane) which must be also below the RSTD resolution. Presently, O-RAN specification proposes relative TE margins to take into account transport asymmetry between 12 and 60 ns depending on synchronization features. But these specifications are proposed while excluding TDOA applications. We can consider those requirements without radio positioning thus as the minimum requirements for supporting radio positioning based on time measurements. **(Table 23)** + +| | | | | +|----------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| +| Network latency asymmetry up & down-link fronthaul | With radio positioning service based on time measurement | | | +| | 4G | 5G FR1 | 5G FR2 | +| Legacy fronthaul (CPRI) | <p>O-DU could compensate this asymmetry for known value in the margin of +/- 10 000 ns.</p> <p>Latency network asymmetry < Observed Time Difference of Arrival (OTDOA) resolution 32.5 ns (or 16.2 ns)</p> <p>The proposition of values by WG9</p> <ul style="list-style-type: none"> <li>- For negligible impact on geolocation time measurement</li> </ul> <p>Latency network asymmetry < 3 ns (10% of RSTD resolution)</p> <ul style="list-style-type: none"> <li>- For residual impact on geolocation time measurement</li> </ul> <p>Latency network asymmetry < 13 ns (10% of RSTD accuracy)</p> | NA | NA | +| O-RAN fronthaul | NA | <p>To be discussed:</p> <p>For negligible impact on geolocation time measurement O-RU TE < 0.8 ns (10% of RSTD resolution) with 0.2ns margin dedicated to fiber asymmetry</p> <p>For residual impact on geolocation time measurement O-RU TE < 3.3 ns (10% of RSTD accuracy) with 1ns margin dedicated to fiber asymmetry</p> | <p>To be discussed:</p> <p>For negligible impact on geolocation time measurement O-RU TE < 0.2 ns (10% of RSTD resolution) with 0.07ns margin dedicated to fiber asymmetry</p> <p>For residual impact on geolocation time measurement O-RU TE < 0.8 ns (10% of RSTD accuracy) with 0.2ns margin dedicated to fiber asymmetry</p> | + +**Table 23:** Network latency asymmetry up & down-link fronthaul with radio positioning + +Concerning jitter and wander, O-RAN transport considers two types of contributions: + +- the Ethernet-type which corresponds to the packet delay variation + +- the physical layer-type which corresponds to the bit delay variation + +For WDM fronthaul, only the “bit” jitter is considered. **Table 24** below presents the existing values for CPRI and must be completed for O-RAN fronthaul. The contribution of auxiliary physical channel (pilot tones) in an overlay of transmission channel must be considered. + +| Jitter (Bit)<br>(without pilot tones) | 4G | 5G | +|---------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----| +| Legacy fronthaul (CPRI) | CPRI (guided by electrical <sup>1</sup> XAUI specifications (IEEE 802.3)) and Freq. deviation: $\pm 2$ ppb (3GPP: 50ppb):<br>- RMS $\approx 1.8$ ps<br>- Peak-To-Peak $\approx 26$ ps | NA | +| O-RAN fronthaul | | | + +**Table 24:** Jitter recommendation for 4G and 5G (without pilot tones) + +### 6.1.1 Phase 2 Latency Asymmetry + +Fronthaul transport delays could have propagation time asymmetry, wander and jitter, caused by: + +- Difference of optical fiber lengths when uplink and downlink use separate fibers (7 m of standard single-mode fiber approximatively corresponds to a 34 ns delay), +- Difference of wavelength propagation times when wavelengths are not close for uplink and downlink (typically 1.3 $\mu\text{m}$ and 1.55 $\mu\text{m}$ wavelength duplex causes 33 to 49 ns time difference (in the function of fiber characteristic, cf. figure below) over 20 km of standard single-mode fiber ITU-T G.652). The choice of WDM technology spectrum location for DWDM, CWDM, MDWM, and others, has an impact on latency variation between wavelength channel pairs and between the wavelengths for up-and down-stream. In the Figure **Figure 18 (a)**, we plotted in the minimal, medium and maximal theoretical delay difference based on dispersion and group Delay third term Sellmeier calculations after transmission in 20 km of G.652 SSMF. The minimal and maximum are obtained with the worst and best cases material properties of the SSMF G.652. With this + +![Figure 18 (a) and (b) showing latency variations. (a) Calculated Group Delay vs Wavelength [nm] from 1250 to 1650 nm. It shows three theoretical curves: Theory Medium (blue dashed line with circles), Theory Min (red dashed line with crosses), and Theory Max (green dashed line with triangles). Measured data points are shown as black squares. A 13ns difference is marked between Theory Max and Theory Min at 1550 nm, and a 9ns difference is marked between Theory Medium and Theory Min at 1550 nm. (b) Latency Variation (ns) vs Wavelength (nm) from 1250 to 1600 nm. It shows the mean delay variation for different WDM technologies: PtP Up & Down (black squares), 8 MWDM pairs (green circles), CWDM (blue squares), and 40CH DWDM (red squares). Specific values are highlighted: Max 4G RSTD: 32.6ns, Max 5G FR1 RSTD: 8.1ns, and Max 5G FR2 RSTD: 2ns.](2acdaa24e06a2484722735c1a2f42e49_img.jpg) + +Figure 18 (a) and (b) showing latency variations. (a) Calculated Group Delay vs Wavelength [nm] from 1250 to 1650 nm. It shows three theoretical curves: Theory Medium (blue dashed line with circles), Theory Min (red dashed line with crosses), and Theory Max (green dashed line with triangles). Measured data points are shown as black squares. A 13ns difference is marked between Theory Max and Theory Min at 1550 nm, and a 9ns difference is marked between Theory Medium and Theory Min at 1550 nm. (b) Latency Variation (ns) vs Wavelength (nm) from 1250 to 1600 nm. It shows the mean delay variation for different WDM technologies: PtP Up & Down (black squares), 8 MWDM pairs (green circles), CWDM (blue squares), and 40CH DWDM (red squares). Specific values are highlighted: Max 4G RSTD: 32.6ns, Max 5G FR1 RSTD: 8.1ns, and Max 5G FR2 RSTD: 2ns. + +**Figure 18 (a)** : Measured Latency and theoretical delay variations according to wavelengths transmitted in 20 km SSMF; (b) Mean delay variation with wavelength after 20 km SSMF and corresponding MWDM, CWDM and DWDM spectral ranges. + +<sup>1</sup> CPRI does not give the relevant base for optical interface (only for electrical interface) + +theoretical approach, we estimate that a maximum delay variation of 20ns is expected for each wavelength of the C-band. Also, we noted that a minimum delay variation of 9 ns is expected between extreme C-band channels at 1529nm and 1565nm whereas the maximum difference could be 13ns for the worst case of fiber material. For a clearer results exploitation, the maximum theoretical delay curve is plotted in Figure 18 (b) with noted references to the identified WDM technologies spectral ranges. In the O-band, delays will remain low and the upstream/downstream wavelength pairing chosen by PtP and MWDM will induce propagation delay asymmetry that will remain below 2ns. That is compatible with the RSTD limitations for 4G and 5G FR1 for 5G FR2. However, for CWDM and DWDM the upstream/downstream wavelength pairing could induce high delay asymmetries. 68ns between 1311nm and 1611nm CWDM channels pairs or at the best case if two adjacent channels are chosen, 8ns delay asymmetry is expected which exceeds 5G-FR2 RSTD specifications. For 40 DWDM channels in the C-band, a maximum of 12ns delay asymmetry is estimated if wavelength pairs are chosen at the extreme ranges. Finally, the choice of adjacent DWDM channels pairs is required to maintain a downstream/upstream delay asymmetry below all RSTD specifications. + +- The cable length variation is due to temperature changes (40ps/km/K is a typical value). So, for 10 km and a temperature variation of 10°C, we obtain a 4 ns delay variation (wander). +- The difference of processing time (including functions such as time multiplexing, encapsulation, compression, advanced modulation format) at the RAN equipment. + +The most popular optical solution to support fronthaul is based on a direct fiber with two transceivers at the end faces. A single fiber bidirectional transceiver allows to simplify fiber operations and decrease the risk of latency asymmetry. When wavelength division multiplexing (WDM) technology is used to decrease the number of required fibers for multiple links, the network trunk (between multiplex and demultiplexer) could be based on single-fiber bidirectional. + +### 6.1.2 Phase 2 Latency Classification + +Concerning fronthaul latency, several classes of latency have been proposed. All of them are targeted to support the mobile deployment in meeting the overall latency requirements, with considering leaving sufficient margin for mobile equipment processing. Now, in the function of radio (physical layer) performances (NR – New Radio for 5G), the fronthaul latency is defined in **Table 25** + +| Latency fronthaul class | Maximum one-way frame delay performance/equivalent length of fiber | Use case | +|-------------------------|--------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------| +| <b>High25</b> | 25μs / 5 km | Ultra-low latency performances | +| <b>High75</b> | 75μs / 15 km | For full new radio (5G) performances with fiber lengths in 10 km range with active transport equipment and 15 km for passive WDM or dark fiber transmission. | +| <b>High100</b> | 100μs / 20 km | For standard new radio (5G) performances with fiber lengths in 10km range with active transport equipment and 20 km for passive WDM or dark fiber transmission. | +| <b>High200</b> | 200μs / 40 km | For installations with fiber lengths in 30km range with active transport equipment and 40 km for passive WDM or dark fiber transmission | +| <b>High500</b> | 500μs | Large latency installations > 30 km | + +**Table 25:** Fronthaul latency Source: O-RAN WG9 “Xhaul Transport Requirements + +For WDM Fronthaul, the main interests are High25, High75, and optionally High100 + +### 6.1.3 Phase 3 Asymmetry with WDM + +Signal processing chain and reboot of optical transceivers or their host line cards may introduce delay asymmetry between Tx and Rx, resulting in PTP time error. Generally there are two types of asymmetries that may occur in the optical transceiver, namely static asymmetry and dynamic (or semi-dynamic) asymmetry [REF: WG9 sync solution]. In case of using the DWDM optics based on intensity-modulation and direct-detection (IM/DD), only trivial static asymmetry can be foreseen, compared to other propagation delay asymmetry (e.g. fiber links, active or passive optical components, etc.). However, when considering more advanced WDM transceivers for higher capacity in the future, such as clock/data recovery (CDR), coherent transceiver or the ones involving digital signal processing (DSP), it is important to understand the additionally provoked dynamic asymmetry. + +A typical DSP processing involves many functional blocks (e.g. channel equalization, frequency/phase correction, error correction, etc.) which need symbol retiming, the internal derived clock phase from the input signal may vary after each reboot. Such a dynamic asymmetry is difficult to estimate, and therefore often the worst dynamic asymmetry is assumed for the calculation of the time error budget. + +To estimate and ultimately alleviate the asymmetry inside the optical transceiver, OIF’s CFP2-DCO specification defines optional Tx/Rx clock monitor and offers a possibility to use a reference clock for transmitter path retiming [REF: OIF CFP2-DCO]. Similarly, QSFP-DD MSA specifies an optional ePPS/Clock PTP Reference Clock which is a programable timing and clock input for delay compensation within the module [REF: QSFP-DD MSA]. + +On the fiber link side, there are different considerations between dual-fiber working and single-fiber working: + +#### Dual-fiber working delay asymmetry + +![Diagram illustrating dual-fiber working delay asymmetry. It shows an upstream path from a MUX to a DEMUX and a downstream path from a DEMUX to a MUX. A fiber cut is indicated between the MUX and DEMUX. The diagram shows the repair of the fiber length upstream and downstream, resulting in a 10m = 50ns delay. The CD (Chromatic Dispersion) section shows that the same up- and downstream wavelength results in Δnm_upstream-downstream = 0 nm, and the CD asymmetry is calculated as 18 ps/(nm*km) * 15 km * 0 nm = 0 ps.](6a60ae9f8e5f0b73275b448938b77626_img.jpg) + +upstream + +downstream + +MUX + +DEMUX + +Fiber cut + +Repair fiber length upstream + +Repair fiber length downstream + +10m = 50ns + +$\Delta(\text{MUX}_{\text{fiberlength}} - \text{DEMUX}_{\text{fiberlength}})$ + +$\cdot 5\text{ns/m}$ + +$= ? \text{ ns}$ + +$= \Delta m \cdot 5\text{ns/m}$ + +$= ? \text{ ns}$ + +$\Delta(\text{MUX}_{\text{fiberlength}} - \text{DEMUX}_{\text{fiberlength}})$ + +$\cdot 5\text{ns/m}$ + +$= ? \text{ ns}$ + +CD + +Same up- and downstream wavelength $\rightarrow \Delta n\text{m}_{\text{upstream-downstream}} = 0 \text{ nm}$ + +CD asymmetry = fiber dispersion $\cdot$ fiber length $\cdot \Delta n\text{m}_{\text{upstream-downstream}} =$ + +$18 \text{ ps}/(\text{nm} \cdot \text{km}) \cdot 15 \text{ km} \cdot 0 \text{ nm}$ + +$= 0 \text{ ps}$ + +Diagram illustrating dual-fiber working delay asymmetry. It shows an upstream path from a MUX to a DEMUX and a downstream path from a DEMUX to a MUX. A fiber cut is indicated between the MUX and DEMUX. The diagram shows the repair of the fiber length upstream and downstream, resulting in a 10m = 50ns delay. The CD (Chromatic Dispersion) section shows that the same up- and downstream wavelength results in Δnm\_upstream-downstream = 0 nm, and the CD asymmetry is calculated as 18 ps/(nm\*km) \* 15 km \* 0 nm = 0 ps. + +#### Single-fiber working delay asymmetry + +![Diagram of an asymmetric WDM ring architecture showing fiber cut, filter, and CD effects.](f1a6a7d2f59264715bc9a4280f5acf62_img.jpg) + +The diagram illustrates an asymmetric WDM ring architecture. It shows two (DE)MUX components connected by a fiber link. The left (DE)MUX has upstream and downstream ports. The right (DE)MUX also has upstream and downstream ports. A fiber cut is indicated by a red 'X' on the fiber link. A 1650nm filter is shown in the center. The diagram includes calculations for fiber dispersion and CD asymmetry. + +**Fiber cut:** Repair fiber length upstream = Repair fiber length downstream = 0 ns + +**No amp:** 0m = 0ns + +**Filter:** Filter1<sub>fiberlength</sub> = Filter2<sub>fiberlength</sub> = 0 ns + +**CD:** Different up- and downstream wavelength, separated by 100GHz = 0.8nm + +CD asymmetry = fiber dispersion · fiber length · $\Delta n_{\text{upstream-downstream}}$ + +18 ps/(nm·km) · 15 km · 10 nm = 2700 ps + +**Calculated: 1.4 ns** + +Diagram of an asymmetric WDM ring architecture showing fiber cut, filter, and CD effects. + +## 6.2 Bit Errors + +The following **Table 26** provides specifications about the Bit Error Rate and Frame Loss ratios limits + +| Bit Errors or<br>Frame Loss | 4G | 5G | +|-------------------------------|---------------------------------------------------------------|----| +| Legacy<br>fronthaul<br>(CPRI) | BER < 10 <sup>-12</sup> | NA | +| O-RAN<br>fronthaul | O-RAN WG9 “Xhaul Transport Requirements” section 7.2, Table 2 | | + +**Table 26:** BER and Frame Loss Ratio + +## 6.3 Protection + +The topic of protection was previously discussed in “transport requirements” of O-RAN WG9 section 11.1.5. A fronthaul solution should provide a 1:1 or 1+1 backup mechanism in case of fiber failure with passive, active, or semi-active dedicated equipment. + +## 6.4 Synchronization + +WG9 is working on synchronization solutions for O-RAN networks and is expected to submit a document for approval by March 2021. The Open X-haul synchronization (sync) solution and architecture model enables operators to understand different synchronization options and deployment models and helps them to develop the right network sync model that can support the different 5G services and radio architectures. + +WDM is layer 1 and is typically transparent to the RAN sync. The only time there may be an issue is in an asymmetric WDM ring architecture where there can be different fiber route lengths on north and south segments. + +![Figure 19: Asymmetric WDM ring architecture. The diagram shows a ring topology where multiple O-RU units are connected to a central WDM node. This node is connected to another WDM node, which is then connected to an O-DU unit. The fiber segments between the WDM nodes are of different lengths, as indicated by the different colored lines (green, yellow, orange) representing the fiber paths.](a10f11c3136df6da56ecea0b62f6fbf9_img.jpg) + +Figure 19: Asymmetric WDM ring architecture. The diagram shows a ring topology where multiple O-RU units are connected to a central WDM node. This node is connected to another WDM node, which is then connected to an O-DU unit. The fiber segments between the WDM nodes are of different lengths, as indicated by the different colored lines (green, yellow, orange) representing the fiber paths. + +**Figure 19:** Asymmetric WDM ring architecture each WDM segment is a different fiber length + +In an asymmetric WDM ring architecture, most WDM Active systems will have differential delay compensation that will enable all delays across the fiber segments to be equal. This will mitigate any sync issues contributed by an asymmetric environment. (Figure 19) + +![Figure 20: Point to Point WDM architecture. The diagram shows a direct connection between a WDM node and an O-DU unit. The O-RU units are connected to the WDM node. The fiber segment between the WDM node and the O-DU unit is a single, uniform length, represented by a single colored line (green, yellow, orange).](da4af3c1282df1a27f0b0fe00bcf2361_img.jpg) + +Figure 20: Point to Point WDM architecture. The diagram shows a direct connection between a WDM node and an O-DU unit. The O-RU units are connected to the WDM node. The fiber segment between the WDM node and the O-DU unit is a single, uniform length, represented by a single colored line (green, yellow, orange). + +**Figure 20:** Point to Point WDM architecture one segment of fiber length + +In a point-to-point architecture, the WDM solution will be transparent to the RAN synchronization (Wavelength pairing will not exceed the maximum delay asymmetry). (Figure 20) + +### 6.4.1 Phase 2 WDM delivery sync + +It should be noted that the following solution of delivering PTP timing over WDM may be more applicable for x-haul transport networks, offering another alternative to guarantee timing accuracy over a longer timing delivery link from the core to radio sites. Specifically, the optical WDM transport technology can be considered to eliminate asymmetric delay by transmitting bidirectional PTP flows over closely spaced wavelengths using a common fiber and by compensating any residual static asymmetrical delay numerically. + +The approach applies to passive and active WDM transmission, single and duplex fiber strands. + +The two up-and-downlink wavelengths used by the bidi-SFP should be as close as possible to mitigate any latency asymmetry. + +The T-GM (or PRTC/ePRTC) is located in the core or with O-CU, while a timing device at the O-DU (or CSR, HSR, or potentially O-RU) site feeds PTP packets to the O-DU (or CSR, HSR, or potentially O-RU) devices. It is possible that the timing device has multiple Ethernet ports to be connected with the respective devices. (Figure 21) + +![O-RAN Alliance Logo](14e40a84f98b05795aac8457fc3d123c_img.jpg)**O-RAN.WG9.WDM.0-R004-v05.00** + +![Synchronization delivery over passive and active WDM transmission](15afb3e3af69290f2367d001a47abb08_img.jpg) + +**Figure 21:** Synchronization delivery over passive and active WDM transmission + +All the aforementioned timing devices can be equipped with bidirectional transceivers for single fiber applications at a pair of alien wavelengths (i.e. not used by x-haul traffic flows) (**Figure 22**). As such, the WDM Xhaul link delivers PTP flows at ultralow asymmetric delay over an integrated wavelength channel, because not only is the asymmetry of duplex fiber strands eliminated, but the PTP flows are also no longer congested with the x-haul traffic if the shared interface is unaware of PTP, which may lead to high packet delay variation. + +![Dedicated wavelength for PTP flows in addition to the data transmission bands](ac167b387be955f9f473383f96aa48b6_img.jpg) + +**Figure 22:** Dedicated wavelength for PTP flows in addition to the data transmission bands + +The transmission delay in an optical fiber depends on the wavelength, i.e. + +$$D(\lambda) = \frac{1}{l} \frac{d\delta}{d\lambda}$$ + where $D$ is dispersion coefficient, $l$ is fiber length, $\delta$ is group propagation delay, and $\lambda$ is wavelength. The related constant time error (cTE) is half of the packet delay asymmetry, i.e. + +$$cTE = \frac{\delta_{BWD} - \delta_{FWD}}{2}$$ + where $\delta$ is an average delay in forward $\delta_{FWD}$ and backward $\delta_{BWD}$ direction. + +Therefore, given a fiber link length of 50 km using alien PTP wavelengths at 1615nm and 1605nm, where the dispersion coefficient is about 18 ps/nm·km, the residual cTE is bounded to + +--- + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 49 + +Orange Restricted + +$$cTE \approx \frac{50km}{2} 10nm \frac{18ps}{nm \cdot km} = 4.5ns$$ + +Such a PTP delivery over auxiliary WDM wavelengths can be also applied to a multi-hop x-haul transport, e.g. a chain of T-BCs (e.g. O-RAN LLS-C3 configurations), where the up- and downlink PTP wavelength can be alternated to compensate latency asymmetry. **(Figure 23)** + +![Figure 23: Up- and downstream wavelength alternating for PTP flows over multiple WDM hops. The diagram shows a sequence of network elements: T-GM, T-BC, T-BC, T-BC, T-BC. Between T-GM and the first T-BC, and between subsequent T-BCs, there are two parallel paths. The top path is labeled with wavelength λ1 and the bottom path with λ2. The paths alternate between λ1 and λ2 for each hop. The text 'PTP over BiDi WDM' is written in pink on the right.](7641f3461e8409bf6c6d04273f0e9851_img.jpg) + +Figure 23: Up- and downstream wavelength alternating for PTP flows over multiple WDM hops. The diagram shows a sequence of network elements: T-GM, T-BC, T-BC, T-BC, T-BC. Between T-GM and the first T-BC, and between subsequent T-BCs, there are two parallel paths. The top path is labeled with wavelength λ1 and the bottom path with λ2. The paths alternate between λ1 and λ2 for each hop. The text 'PTP over BiDi WDM' is written in pink on the right. + +**Figure 23:** Up- and downstream wavelength alternating for PTP flows over multiple WDM hops + +### 6.4.2 Phase 2 OTDR-based latency characterization + +In addition, optical time-domain reflectometry (OTDR) is a well-known method to measure the propagation delay between two fiber ends or between reflection or attenuation events in a fiber. An optical pulse with a length of typically between 3 ns and 10 μs is transmitted into the fiber, and the reflected and backscattered optical signal fractions are received at the transmission end of the fiber as a function over time. As the propagation delay for the optical signals is the same in both transmission directions, the difference between the round-trip delays of the reflected signals from the fiber input and the fiber end is twice the propagation delay of the fiber. **(Figure 24)** + +![Figure 24: Fiber propagation delay measurement based on OTDR. The diagram shows a network architecture with CU, DU, and RU blocks connected in series. An OTDR is connected to the DU. A probe pulse is sent from the OTDR into the fiber, and a response is received back at the OTDR. The round-trip time is indicated by a bracket above the probe and response paths. The fiber is represented by a wavy line with a color gradient from blue to red.](cd27028e0175f9d3a05cb51f253fd1db_img.jpg) + +Figure 24: Fiber propagation delay measurement based on OTDR. The diagram shows a network architecture with CU, DU, and RU blocks connected in series. An OTDR is connected to the DU. A probe pulse is sent from the OTDR into the fiber, and a response is received back at the OTDR. The round-trip time is indicated by a bracket above the probe and response paths. The fiber is represented by a wavy line with a color gradient from blue to red. + +**Figure 24:** Fiber propagation delay measurement based on OTDR + +The tradeoff between accuracy (pulse width) and reach (receiving sensitivity): + +- 3-5 ns pulse width to cover 0.5-2 km range +- 20 ns pulse width to cover 10 km range + +The accuracy of the measurement is limited to a few nanoseconds due to the length of the test pulse. To achieve a sufficient signal-to-noise ratio, longer probe pulses are required for longer fibers with a higher loss. In an alternative OTDR implementation, a bit sequence at a rate of a few Gbit/s can be used as the test signal. + +The reflected signals are cross-correlated with the transmitted bit pattern, improving the resolution of this correlation OTDR to less than 10 picoseconds. **(Figure 25-27)** + +![Figure 25: OTDR using specific data patterns and correlation. The diagram shows a network architecture with CU, DU, and RU blocks. An OTDR block is connected to the DU. A 'Probe' signal is sent from the OTDR to the RU, and a 'Response' signal is received back. The signal path includes two optical amplifiers (represented by trapezoidal blocks) and a fiber link (represented by a wavy line).](42635a3467ae8c12d3d176f1e7422b6c_img.jpg) + +Figure 25: OTDR using specific data patterns and correlation. The diagram shows a network architecture with CU, DU, and RU blocks. An OTDR block is connected to the DU. A 'Probe' signal is sent from the OTDR to the RU, and a 'Response' signal is received back. The signal path includes two optical amplifiers (represented by trapezoidal blocks) and a fiber link (represented by a wavy line). + +**Figure 25:** OTDR using specific data patterns and correlation + +Other options for OTDR-based latency monitoring are depicted below: + +![Figure 26: Tunable OTDR for passing through WDM channels. The diagram shows a network architecture with CU, DU, and RU blocks. An OTDR block is connected to the DU. A 'Probe' signal is sent from the OTDR to the RU, and a 'Response' signal is received back. The signal path includes two optical amplifiers and a fiber link.](9587b931521cbef1dc97ae2acb1278fb_img.jpg) + +Figure 26: Tunable OTDR for passing through WDM channels. The diagram shows a network architecture with CU, DU, and RU blocks. An OTDR block is connected to the DU. A 'Probe' signal is sent from the OTDR to the RU, and a 'Response' signal is received back. The signal path includes two optical amplifiers and a fiber link. + +**Figure 26:** Tunable OTDR for passing through WDM channels + +- Pros: end-to-end WDM link +- Cons: additional loss, more expensive system + +![Figure 27: Non-intrusive monitoring channel. The diagram shows a network architecture with CU, DU, and RU blocks. An OTDR block is connected to the DU. A 'Probe' signal is sent from the OTDR to the RU, and a 'Response' signal is received back. The signal path includes two optical amplifiers and a fiber link. An auxiliary wavelength (Aux. λ) is also shown.](3c29d92e4e25a999b86146771f08e6a5_img.jpg) + +Figure 27: Non-intrusive monitoring channel. The diagram shows a network architecture with CU, DU, and RU blocks. An OTDR block is connected to the DU. A 'Probe' signal is sent from the OTDR to the RU, and a 'Response' signal is received back. The signal path includes two optical amplifiers and a fiber link. An auxiliary wavelength (Aux. λ) is also shown. + +**Figure 27:** Non-intrusive monitoring channel + +- Pros: easiest deployment and lowest cost +- Cons: difficult to characterize distribution patch cords + +While the fiber link must be transparent in both directions to transport the test signal and the reflected signals, the link delay asymmetry can be measured per section, e.g. between amplifier nodes. The delay of a subsystem, which is transparent only in one direction, can also be evaluated by measuring the one-way + +propagation delay using the same OTDR setup. It is recommended to introduce OTDR as latency monitoring in a WDM x-haul transport. + +## 6.5 Maintenance and Operation + +This sub-section was previously discussed in “Xhaul Transport Requirements” of O-RAN WG9 section 11. A fronthaul solution should be able to provide basic OAM functions to the fronthaul networks to provide management capability on fronthaul network itself, including fault management, performance management, configuration management, real-time system status monitor, statistics report, alarm, etc. + +- The supervision, including dying gasp, is discussed in section 11.1.3 of “Xhaul Transport Requirements” of O-RAN WG9 +- The rogue behavior mitigation is discussed in section 11.1.4 of “Xhaul Transport Requirements” of O-RAN WG9 +- The transceiver features are discussed in sections 11.2.1, 11.2.2, and 11.2.3 of “Xhaul Transport Requirements” of O-RAN WG9 +- To facilitate retrieval of the transport port identifier and other physical layer parameter indicators (ex. Launched optical power) during field operation (installation, maintenance, etc....), a wavelength port-ID could be tagged on the transport hub equipment. In section 11.2.4 of “transport requirements” of O-RAN WG9, we consider port-ID that we expand to wavelength-ID for WDM transport. +- Eye safety is discussed in section 11.2.5 of “Xhaul Transport Requirements” of O-RAN WG9 +- The power-saving is discussed in section 11.3 of “Xhaul Transport Requirements” of O-RAN WG9. The O-RU and O-DU have their power-saving policy. The WDM transmission equipment must be capable to support the DU and O-RU power saving cycle without perturbation. Therefore, WDM equipment power saving mode must be done in coordination with O-DU and O-RU. Attention must be given to the timing of the ON and OFF state of the working wavelength (ex. The ON state timing consider the timing to achieve the adequate optical power and wavelength) in the function of the required timing of the power saving cycle. + +The WDM transport must be capable to support also remote monitoring cell site operation and it is discussed in section 11.4 of “Xhaul Transport Requirements” of O-RAN WG9 + +# 7 Operation Administration Maintenance (OAM) Requirements + +## 7.1 OAM Architecture + +In the C-RAN fronthaul transport scheme, xWDM equipment includes the far-end (near the O-RU/O-RU) and station-site device (near the O-DU) (**Figure 28**) + +![Diagram of OAM Architecture showing Far-End and Station-site devices connected by a line, with a vertical ellipsis indicating multiple instances.](76857c84b720a1d2c703c074e93b91bb_img.jpg) + +``` + +graph TD + FE[Far- End] --- SS[Station- site] + FE -.- SS + +``` + +Diagram of OAM Architecture showing Far-End and Station-site devices connected by a line, with a vertical ellipsis indicating multiple instances. + +**Figure 28:** Definition of Far End and Station Site scheme + +At the far-end and the station-end, 3 functions shall be provided by Fronthaul WDM OAM mechanism + +- Configuration: Station-site shall send a configuration message to the far-end, then a response shall be sent from the far-end. +- Inquiry: Station-site shall send an inquiry message to the far-end, then the far-end shall reply with a result message. +- Active: For a specific link, station-site and far-end both need to send some state message periodically to keep the link alive. + +xWDM equipment OAM function provides operation, administration, and maintenance including daily operation, fault prediction, and network management. + +We consider OAM for the WDM fronthaul transmission including section 5.5 required features. We propose the OAM architecture for passive, active, and semi-active solutions presented in section 2. The WDM Management Plane “M-plane” and WDM pairing activity should be performed as a first step in the link activation procedure: proper error messages have to be sent (e.g. optical link down (passive), WDM wavelength mismatch (active, semi-active)). The following requirements are proposed for WDM-based fronthaul networks, and it is proposed the M-plane be adapted following the O-RAN WG4 requirements on this issue. + +### For passive WDM: + +![Figure 29: OAM for Passive WDM](168a99f34654ddff7d1eb326bd3ba8c0_img.jpg) + +Figure 29: OAM for Passive WDM + +**Figure 29:** OAM for Passive WDM + +The main OAM is done by O-RU and O-DU and the WDM link must remain transparent. The supervision, dying gasp, port, and wavelength-ID, alarms, energy-saving policy are achieved by the O-DU and the O-RU. The M-plane could be based on ITU-T G.988 recommendations. The only specific OAM function concerns the wavelength assignment and control to achieve the wavelength pairing when tunable transceivers are used. An embedded channel must be defined based on digital or analog transmission to support this wavelength pairing. + +O-RAN.WG9.WDM.0-R004-v05.00 + +Image: O-RAN Alliance Logo + +OAM. This embedded OAM channel must allow interoperability between transceivers face to face. The O-RAN transceiver embedded channel could be based on auxiliary management and control channel of ITU-T G.989.2 **Annex B & ITU-T G.989.3 Annex F & G.** +**For active WDM:** +![OAM for Active WDM Diagram](2ec5225bbece9e125a50bd7b410149f6_img.jpg) + +A block diagram showing the OAM architecture for Active WDM. It illustrates the connection between O-RU and O-DU through TNE (Transport Network Equipment) and WDM devices. The planes shown are C/U/S-Planes, M-Plane, and M-Plane (WDM). A Management System is connected to both TNEs and the O-DU. Below the block diagram, a physical representation shows AAU/O-RU antennas connected to WDM, which connects to another WDM and then to the DU/O-DU. Arrows indicate 'C/U/S- and M-planes between DU-RU (WG4)' and 'OAM dedicated to WDM (WG9)'. + +OAM for Active WDM Diagram + +**Figure 30:** OAM for Active WDM + +The O-DU and O-RU communication are transparent to the wavelength transmission features. The O-DU and O-RU support a dedicated OAM link with grey transceivers. Therefore, for active WDM transmission, a dedicated OAM based on section 56 must be proposed. The OAM coordination between TNE and O-DU & O-RU by management system must be proposed for supervision, power saving mechanism, port & wavelength-ID. An asymmetrical TE OAM could be preferred with master TNE close to O-DU and slave TNE close to O-RU. + +**For semi-active WDM type I:** +![OAM for semi-active WDM type I Diagram](074b1f1fa3e943c91a68a92bee042341_img.jpg) + +A block diagram showing the OAM architecture for semi-active WDM type I. It shows O-RU with a Transceiver (Tr) connected to TE (Transport Equipment) and O-DU. The planes shown are C/U/S-Planes, M-Plane, and WDM pairing. A Management System is connected to the TE and O-DU. Below, a physical representation shows AAU antennas with transceivers connected via fiber to a WDM device, which then connects to the DU. Arrows indicate 'C/U/S- and M-planes between DU-RU (WG4)' and 'OAM dedicated to WDM (WG9)'. + +OAM for semi-active WDM type I Diagram + +**Figure 31:** OAM for semi-active WDM type I + +© 2024 by the O-RAN ALLIANCE e.V. Your use is subject to the copyright statement on the cover page of this specification. 54 +Orange Restricted + +The O-DU is transparent to the wavelength transmission features. The O-RU supports the WDM transceiver. The O-RU M-Plane is capable of supporting the OAM for WDM transmission. The M-Plane dedicated to the OAM function controls the wavelength assignment to achieve the wavelength pairing. An embedded channel must be defined based on digital or analog transmission to support this wavelength pairing OAM. This embedded OAM channel must allow interoperability between transceivers face to face. The O-RAN transceiver embedded channel could be based on auxiliary management and control channel of ITU-T G.989.2 Annex B & ITU-T G.989.3 Annex F & G. The TNE close to O-DU is also connected to the management system to enrich the WDM OAM features. The OAM architecture is asymmetrical with the TNE equipment close to DU which achieves a master role. + +### For semi-active WDM type II: + +![Figure 32: OAM for semi-active WDM type II. The diagram shows the OAM architecture for semi-active WDM type II. It includes a legend: Tr: Transceiver, TE: Transport Equipment. The main components are O-RU (left) and O-DU (right). The O-RU contains a Transceiver (Tr) and is connected to the O-DU's Transceiver (Tr) via C/U/S-Planes, M-Plane, and WDM pairing. The O-DU contains a Transceiver (Tr) and is connected to the O-RU's Transceiver (Tr) via C/U/S-Planes, M-Plane, and WDM pairing. A TNE (Transport Network Element) is connected to the O-DU's Transceiver (Tr) and the Management system. A Power Detector is connected to the O-DU's Transceiver (Tr) and the Management system. The O-RU is connected to the O-DU via C/U/S- and M-planes between DU-RU (WG4). The OAM architecture is asymmetrical with the TNE equipment close to DU which achieves a master role. The optical power detectors system of the WDM link is also connected to the management system to enrich the OAM features. The OAM architecture is asymmetrical with the TNE equipment close to DU which achieves a master role. The optical detectors system could have a role in the wavelength pairing mechanism. Or the optical detectors system could have no role in the wavelength pairing mechanism and provide 'only' optical supervision parameters.](9c58a6c1b6d09675a32b8302e12b5a33_img.jpg) + +Figure 32: OAM for semi-active WDM type II. The diagram shows the OAM architecture for semi-active WDM type II. It includes a legend: Tr: Transceiver, TE: Transport Equipment. The main components are O-RU (left) and O-DU (right). The O-RU contains a Transceiver (Tr) and is connected to the O-DU's Transceiver (Tr) via C/U/S-Planes, M-Plane, and WDM pairing. The O-DU contains a Transceiver (Tr) and is connected to the O-RU's Transceiver (Tr) via C/U/S-Planes, M-Plane, and WDM pairing. A TNE (Transport Network Element) is connected to the O-DU's Transceiver (Tr) and the Management system. A Power Detector is connected to the O-DU's Transceiver (Tr) and the Management system. The O-RU is connected to the O-DU via C/U/S- and M-planes between DU-RU (WG4). The OAM architecture is asymmetrical with the TNE equipment close to DU which achieves a master role. The optical power detectors system of the WDM link is also connected to the management system to enrich the OAM features. The OAM architecture is asymmetrical with the TNE equipment close to DU which achieves a master role. The optical detectors system could have a role in the wavelength pairing mechanism. Or the optical detectors system could have no role in the wavelength pairing mechanism and provide 'only' optical supervision parameters. + +**Figure32:** OAM for semi-active WDM type II + +The OAM of the WDM links is done by O-RU and O-DU OAM. The supervision, dying gasp, port, and wavelength-ID, alarms, energy-saving policy are achieved by O-DU and O-RU. The only specific OAM function controls the wavelength assignment to achieve wavelength pairing. An embedded channel must be defined based on digital or analog transmission to support this wavelength pairing OAM. This embedded OAM channel must allow interoperability between transceivers face to face. The O-RAN transceiver embedded channel could be based on auxiliary management and control channel of ITU-T G.989.2 Annex B & ITU-T G.989.3 Annex F & G. The optical power detectors system of the WDM link is also connected to the management system to enrich the OAM features. The OAM architecture is asymmetrical with the TNE equipment close to DU which achieves a master role. The optical detectors system could have a role in the wavelength pairing mechanism. Or the optical detectors system could have no role in the wavelength pairing mechanism and provide “only” optical supervision parameters. + +The following table presents a synthesis of OAM architectures. + +| | OAM architectures | +|-------------|------------------------------------------------------------------------| +| passive WDM | dedicated to wavelength pairing only if required (Tunable transceiver) | + +| | | +|-------------------------|----------------------------------------------------------------------------------------------------------------------------------------------| +| active WDM | complete WDM transmission OAM, asymmetrical OAM with slave and master transport equipment, and coordination with the O-RAN management system | +| semi-active WDM type I | dedicated to wavelength pairing only if required (Tunable transceiver) | +| semi-active WDM type II | dedicated to wavelength pairing only if required (Tunable transceiver) | + +**Table 27:** Synthesis of OAM for the four proposed WDM implementations + +The following table presents KPIs [Key Performance Indicators] to be reported by the optical transceivers. + +| KPI | Description | +|-------------------|-----------------------------------| +| Vendor | Transceiver Manufacturer | +| Vendor Product | Transceiver part number | +| Revision | Transceiver revision FM/SW | +| Date | Transceiver Date of revision | +| Temp | Transceiver temperature | +| TX Optical power | Transceiver Optical Launch power | +| RS Optical power | Transceiver Optical Receive power | +| TX supply Voltage | Transceiver voltage | +| TX Bias Current | Transceiver Bias Current Draw | +| Frequency TX | Transceiver Frequency (GHz) | +| Frequency RX | Receiver Frequency (GHz) | + +**Table 28:** Optical transceivers reported parameters + +## 7.2 Configuration + +Loopback configuration for fixed or self-tuning transceivers (subject to operator preference) is a very common requirement for debugging and *may* be implemented for bringing up the link and its troubleshooting. If loopback is implemented, the station site shall send a loopback configuration message to set the far end module to loopback mode. The loopback message would set the port to loopback condition. After receiving the configuration message, the far end shall reply with a feedback message such as loopback acknowledged. To turn off the loopback condition, a separate message shall be sent by the local entity; again, an acknowledgment message shall be sent back to the local entity. + +- The station site could send a power configuration message to set the transmitting optical power of the far end module (After receiving the configuration message, the far end should reply with a feedback message) +- When the far end module is in the loopback mode, the station site could continuously send the test message. An analysis at the sink side can be very helpful for debugging. + +## 7.3 Enquiry + +- The station site could send an inquiry message for the vendor information of the far-end module. The reply from the far end module should be received by the station site within a limited time (e.g., 1-sec), otherwise a timeout alarm should be generated. +- The same inquiry process can be used for the transmit power, receive power, volt, temperature, etc. of the far end module. + +## 7.4 Active + +- Station site and far end send the keep-alive message (handshake message, e.g., machine state) to each other in the idle state to keep the link active +- When the faulty condition is met, a Loss of Signal “LOS” message should be sent immediately. (e.g., the RDI in G.709 or remote fault in IEEE 802.3) +- When the faulty condition is met, a power or temperature alarm message should be sent immediately. +- Similar to the keep-alive message, the module state could be sent periodically, thus long-term monitoring can be achieved. +- Similar to the keep-alive message, vendor information could be sent periodically, thus long-term monitoring can be achieved. + +## 7.5 Phase 3 OAM In Fronthaul + +In section 6.1, an embedded channel is used for semi-active WDM to support the wavelength pairing OAM. In this section, besides wavelength pairing, the detailed OAM functions based on pilot-tone are specified for front-haul application. + +For semi-active WDM type I, the OAM information are framed as OAM message and modulated on the service optical signals in the colored optical modules of O-RUs, including the wavelength, ID, transmitting optical power, receiving optical power of optical modules, etc, as shown in Table 28. For 5G front-haul, the frequency of eCPRI optical signal is 25G and the repetition of low-speed in-band OAM message is usually kHz to 100MHz. For WDM optical signals, the carrier frequencies of OAM messages can be same or different. If multi-carrier OAM modulation is used, the modulation frequency of OAM should be unique for each WDM optical signals with different wavelengths. The optical modules in active WDM equipment receive the optical signal with OAM message and an OAM process unit in optical module can extract the OAM messages. As specified in section 6.2~6.4, OAM functions including configuration, enquiry, and active should be supported for semi-active WDM type I. With the received OAM messages, the WDM equipment can manage and control the front-haul network, including verifying the status of optical link, wavelength assignment, Loopback configuration, transmitting optical power adjustment, etc. + +For semi-active WDM type II, the OAM process is similar with that of semi-active WDM type I as the OAM messages from O-RUs and O-DUs are extracted in an OAM process unit of active WDM equipment rather than optical module. + + + +# 8 Management Interfaces + +**Table 29** is only a high-level feature list, there will be a much more detailed comparison and gap analysis of the YANG models after a shortlist of models has been selected. + +| | | | Common Shelf<br>(active) | TPDR | +|----------|-------------------------|-------------------------|--------------------------|------| +| CM | Interfaces | Ethernet | | x | +| | | OTS/OMS | X (active-active) | | +| | | OCH | x | x | +| | | OSC | X (active-active) | | +| | Equipment | Shelf | x | x | +| | | Card | x | x | +| | | slot | x | x | +| | | subslot | x | x | +| | | port | x | x | +| | FW/SW update | | x | x | +| | Database backup/restore | | x | x | +| | Path protection | | x | x | +| | synchronization | | TBD | TBD | +| FM | | | x | x | +| PM | | | x | x | +| Security | User management | Multi-user<br>hierarchy | x | x | +| | Certificate handling | | x | x | + +**Table 29:** High-level feature list of a Fronthaul transport system, both common part, and transceiver + +**Table 30** compares the candidates for the YANG models to model a WDM fronthaul system and the high-level features mapped to these models. Once the candidate models have been identified, a more detailed comparison and gap analysis between these YANG data models will be performed. + +| | | | OpenConfig | OpenROADM | TBD | +|----------|-------------------------|----------|---------------------|-----------|-----| +| CM | Interfaces | Ethernet | x | x | | +| | | OTS/OMS | x | x | | +| | | OCH | x | x | | +| | | OSC | x | x | | +| | Equipment | Shelf | x | x | | +| | | Card | x | x | | +| | | slot | x | x | | +| | | subslot | | x | | +| | | port | x | x | | +| | FW/SW update | | SW | x | | +| | Database backup/restore | | | x | | +| | Path protection | | x | x | | +| | synchronization | | TBD | TBD | | +| FM | | | x | x | | +| PM | | | Streaming Telemetry | x | | +| Security | User management | | x | x | | +| | Certificate handling | | x | x | | + +**Table 30:** Model candidates for Fronthaul transport compared to features of a typical system + +# Appendix A Phase 1 Optical Power Budget- + +In this annex, the examples of the optical power budget for DWDM and MWDM with a transmission distance of 10 km are shown as follows. The optical power budget of these WDM technologies over 10 km can be further specified. + +### Example 1: DWDM C-BAND + +Optical link budget assumes $LT = \alpha L + L_c + L_p + L_s$ where: + +TL - Total Loss + +$\alpha$ - Fiber Loss + +L - Length of fiber + +$L_c$ - Connector loss + +$L_p$ - Passive Device Loss + +$L_s$ - Splice loss + +The assumption for losses: + +- G.652 [3] Fiber 0.3 dB per km +- ~0.5 dB (large variance depending on cables and splice methods) for connections and splices + +Assuming fiber loss of 0.3 dB per km and connector and splice loss of 0.5 dB per instance, the below 17 dB link budget provides a design to include quantities of passives devices, connectors, splices, fiber length that is adequate for most architectures. This example is not limited to the below but is only to quantify the optical end-to-end path to include a variety of loss elements. + +The minimum link budget of 17 dB (**Table 31**) is required to overcome typical fiber path designs but is not limited to this value. Higher link budgets (i.e. 19 dB) are recommended assuming the cost of the optic is acceptable. + +| Assuming 10 km reach:(Example)<br>Loss Element | Loss (dB) | +|------------------------------------------------|--------------| +| Fiber Length (10 km) | 3 | +| Assumed fiber connections (12) | 6 | +| Assumed Splices (4) | 2 | +| Splice Coupler | 1.5 | +| Splice Coupler | 1.5 | +| DWDM Mux (dBm) (1.5 each) | 3 | +| Fiber Length (km) ( $\alpha$ ) | 17 | +| | | +| Optical Interface | Optical Spec | +| Optical Launch Min Power (dBm) | 0.5 | +| Receiver Sensitivity (dBm) | -16.5 | +| 10G Optical Link Budget (dB) | 17 | + +**Table 31:** DWDM Link Budget Losses + +![Figure 33: Optical Link Budget Example. The diagram shows an optical link from a Radio (RAN) through DWDM, OSP, Intra Office Cable, and back through DWDM to a BBU (RAN). Components include SFP, EST, Splice Coupler, OSP, Intra Office Cable, Mux, and DWDM Active.](e54fd4c7a54e2814c73032279166c414_img.jpg) + +Figure 33: Optical Link Budget Example. The diagram shows an optical link from a Radio (RAN) through DWDM, OSP, Intra Office Cable, and back through DWDM to a BBU (RAN). Components include SFP, EST, Splice Coupler, OSP, Intra Office Cable, Mux, and DWDM Active. + +Figure 33: Optical Link Budget Example + +### Example 2: MWDM + +15 dB optical power budget for 25 Gbps 10 km 12-λ: + +- The optical power budget of MWDM can be described as follows: +- $T_{OPB} = \alpha * L + L_c + L_p + TDP + MM$ +- where: +- $T_{OPB}$ - Total optical power budget +- $\alpha$ - Fiber loss +- $L$ - Fiber length +- $L_c$ - Connector loss +- $L_p$ - Passive Device Loss (Mux/Demux) +- TDP - Transmitter and Dispersion Penalty +- MM - Maintenance Margin + +For 25 Gbps 12-λ 10 km application of MWDM, a 15 dB optical power budget is required, which is shown in Table 32. Here, the fiber loss is 0.35 dB/km, the number of connectors is 4, the loss of each connector is 0.5 dB, the maintenance margin is 2 dB. + +| Wavelength (nm) | MUX and DEMUX (dB) | TDP (dB) | 10 km fiber loss (dB) | Connector loss (dB) | Maintenance Margin (dB) | TX OMA (dBm) | RX OMA (dBm) | +|-----------------|--------------------|----------|-----------------------|---------------------|-------------------------|--------------|--------------| +| 1374.5-O-RU | 3 | 4.5 | 3.5 | 2 | 2 | 1 | -14 | +| 1367.5-O-DU | 3 | 4.5 | 3.5 | 2 | 2 | 1 | -14 | +| 1354.5-O-RU | 3 | 4.5 | 3.5 | 2 | 2 | 1 | -14 | +| 1347.5-O-DU | 3 | 4.5 | 3.5 | 2 | 2 | 1 | -14 | +| 1334.5-O-RU | 4.5 | 3 | 3.5 | 2 | 2 | 1 | -14 | +| 1327.5-O-DU | 4.5 | 3 | 3.5 | 2 | 2 | 1 | -14 | +| 1314.5-O-RU | 6.1 | 1 | 3.5 | 2 | 2 | 1 | -14 | +| 1307.5-O-DU | 6.1 | 1 | 3.5 | 2 | 2 | 1 | -14 | +| 1294.5-O-RU | 6.1 | 1 | 3.5 | 2 | 2 | 1 | -14 | +| 1287.5-O-DU | 6.1 | 1 | 3.5 | 2 | 2 | 1 | -14 | +| 1274.5-O-RU | 6.1 | 1 | 3.5 | 2 | 2 | 1 | -14 | +| 1267.5-O-DU | 6.1 | 1 | 3.5 | 2 | 2 | 1 | -14 | + +Table 32: 15 dB optical power budget for 25 Gbps 10 km 12-λ MWDM + +For 25 Gbps 12- $\lambda$ 15 km application of MWDM, the optical power budget is shown in Table 33. Here, the number of connectors is 7, the loss of each connector is 0.5 dB, the maintenance margin is 3 dB. It is noted that the 15 km optical power budget of the 6-channel from 1267.5 nm to 1314.5 nm is calculated to be 18.85 dB. However, considering the 20 dB optical power budget of 10 km application with optical protection, the 15 km optical power budget of the 6-channel from 1267.5 nm to 1314.5 nm is specified as 20dB to unify the kind of optical module. + +| Wavelength (nm) | MUX and DEMUX (dB) | TDP (dB) | 15 km fiber loss (dB) | Connector loss (dB) | Maintenance Margin (dB) | TX OMA (dBm) | RX OMA (dBm) | +|-----------------|--------------------|----------|-----------------------|---------------------|-------------------------|--------------|--------------| +| 1374.5-O-RU | 3 | 7 | 5.25 | 3.5 | 3 | 2.75 | -19 | +| 1367.5-O-DU | 3 | 7 | 5.25 | 3.5 | 3 | 2.75 | -19 | +| 1354.5-O-RU | 3 | 6 | 5.25 | 3.5 | 3 | 2.75 | -19 | +| 1347.5-O-DU | 3 | 6 | 5.25 | 3.5 | 3 | 2.75 | -19 | +| 1334.5-O-RU | 4.5 | 4.5 | 5.25 | 3.5 | 3 | 2.75 | -19 | +| 1327.5-O-DU | 4.5 | 4.5 | 5.25 | 3.5 | 3 | 2.75 | -19 | +| 1314.5-O-RU | 6.1 | 1 | 5.25 | 3.5 | 3 | 1 | -19 | +| 1307.5-O-DU | 6.1 | 1 | 5.25 | 3.5 | 3 | 1 | -19 | +| 1294.5-O-RU | 6.1 | 1 | 5.25 | 3.5 | 3 | 1 | -19 | +| 1287.5-O-DU | 6.1 | 1 | 5.25 | 3.5 | 3 | 1 | -19 | +| 1274.5-O-RU | 6.1 | 1 | 5.25 | 3.5 | 3 | 1 | -19 | +| 1267.5-O-DU | 6.1 | 1 | 5.25 | 3.5 | 3 | 1 | -19 | + +**Table 33:** Optical power budget for 25 Gbps 15 km 12- $\lambda$ MWDM + +For 25 Gbps 12- $\lambda$ 20 km application of MWDM, the optical power budget is shown in Table 34. Here, the number of connectors is 8, the loss of each connector is 0.5 dB, the maintenance margin is 3 dB, the optical power budget is 21 dB. It is noted that the max TDP of DML-based MWDM over 20km will be larger than 10dB, the feasibility cannot be accepted. Dispersion compensation can be used to suppress dispersion penalty, but the latency of the 20-km optical link will be more than 100us by introducing DCF. In Table 34, 20-km transmission can be achieved by using EML-based MWDM with 21dB power budget. In this way, DML-based MWDM can satisfy 15km application with low-cost for majority scenario and EML-based MWDM can satisfy 20km application with more cost. + +| Wavelength (nm) | MUX and DEMUX (dB) | TDP (dB) | 20km fiber loss (dB) | Connector loss (dB) | Maintenance Margin (dB) | TX OMA (dBm) | RX OMA (dBm) | +|-----------------|--------------------|----------|----------------------|---------------------|-------------------------|--------------|--------------| +| 1374.5-O-RU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1367.5-O-DU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1354.5-O-RU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1347.5-O-DU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1334.5-O-RU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1327.5-O-DU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1314.5-O-RU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1307.5-O-DU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1294.5-O-RU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1287.5-O-DU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1274.5-O-RU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | +| 1267.5-O-DU | 5 | 2 | 7 | 4 | 3 | 2 | -19 | + +**Table 34:** Optical power budget for 25 Gbps 20 km 12- $\lambda$ MWDM + +### Chromatic Dispersion Coefficient + +Chromatic dispersion (CD) in single-mode fiber causes a receiver sensitivity power penalty compared to the back-to-back (BTB) case. The CD penalty is included in the required receiver sensitivity values listed in the 17 dB DWDM power budget examples and the TDP portion of the 15 dB MWDM power budget example. + +The assumed penalties are based on ITU-T G.652 (2016-11), fiber type G.652.D. Other fiber types, including bend-insensitive fiber, may be used as long as the channel loss, dispersion, and other link parameter limits are not exceeded (**Table 34**) + +| Description | 12 MWDM | 40 DWDM | Unit | +|----------------------------|---------|---------|-------| +| Fiber length (max) | 10 | 10 | km | +| Fiber insertion loss (max) | 4.7 | 3 | dB | +| Fiber insertion loss (min) | 3.2 | | dB | +| Positive dispersion (max) | 63 | 193 | ps/nm | +| Positive dispersion (min) | | 122 | ps/nm | +| Negative dispersion (min) | -56 | | ps/nm | +| DGD max | 8 | 8 | ps | +| Optical return loss (min) | TBD | TBD | dB | + +**Table 34:** Characteristics of a 10 km link based on G.652.D fiber. + +# --- Appendix B Phase 2 >25G Line rate Cover it in an Appendix \ No newline at end of file diff --git a/original/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00.pdf b/original/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..545c972c12761e3ec15bbfe0cf774db66d65cac6 --- /dev/null +++ b/original/SFG/O-RAN.SFG.Non-RT-RIC-Security-TR-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:41b4e4d600c88bb2e662eb8daf4cbd6a1e2942b5e26b9aaaeeeca55dcc228202 +size 864131 diff --git a/original/SuFG/O-RAN.SuFG.CE-v01.00.pdf b/original/SuFG/O-RAN.SuFG.CE-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..e7463bebb433daad3e26320d80ce77e437e5fb8e --- /dev/null +++ b/original/SuFG/O-RAN.SuFG.CE-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b7528ac4539bd4beeef359e60ee97aef9366afaad16c769984565510569e80ce +size 346063 diff --git a/original/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00.pdf b/original/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..96e89ac02e23a9ab9ed239fff8b8541d8cd8c6e6 --- /dev/null +++ b/original/TIFG/O-RAN.TIFG.CGofOTIC.0-v06.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d605211c8ee1f345db812d3e052ec53b0e137d7c8b8c8f9c37c1d4d2a6c2e592 +size 485184 diff --git a/original/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00.pdf b/original/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..7be2ff6f3ef44873d7b2ca0cabd359d75a1e0acf --- /dev/null +++ b/original/TIFG/O-RAN.TIFG.E2ETSTFWK.0-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bffc70106a976b4a09d432772a122b18362f2a03cf0c50ef8f4cae5acfae7bbf +size 2058285 diff --git a/original/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00.pdf b/original/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..22b7572f46bee0efb52f1c9f223b31d179a1b960 --- /dev/null +++ b/original/WG1/O-RAN-WG1-CCIN-TR-R004-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e1310961f80c5d21ef4a2e4a0acac2c9e63ac630172ec0eff0b05e66e00bc1f0 +size 1908891 diff --git a/original/WG1/O-RAN.WG1.Information Model and Data Models-v01.00.pdf b/original/WG1/O-RAN.WG1.Information Model and Data Models-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..9e6f4dc191f1689bd2fcf981129db62bb115a513 --- /dev/null +++ b/original/WG1/O-RAN.WG1.Information Model and Data Models-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:eca6a3ecf1f34501b1ffa6feb1c7f02db03982c3b0d343c0a758911cb0c42b93 +size 798845 diff --git a/original/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00.pdf b/original/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..d1c318008f088f73121e45658514c15846486813 --- /dev/null +++ b/original/WG1/O-RAN.WG1.Network-Energy-Savings-Technical-Report-R003-v02.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:821cf468aa81aa0a3170db6003127a148767793e65dd8fa7b10a6b4ad81bf00c +size 2677945 diff --git a/original/WG1/O-RAN.WG1.O1-Interface.0-v04.00.pdf b/original/WG1/O-RAN.WG1.O1-Interface.0-v04.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..95f8b4cf9a78fe8ce75369b0688865b85be74ad4 --- /dev/null +++ b/original/WG1/O-RAN.WG1.O1-Interface.0-v04.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e56216c86b396d4c44c3a600f2facf0862b7c706a6b0464824d95f092197a7c2 +size 1585899 diff --git a/original/WG1/O-RAN.WG1.OAM-Architecture-v04.00.pdf b/original/WG1/O-RAN.WG1.OAM-Architecture-v04.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..148d7c48b761bb069e005e4ce034ca6657a0ec76 --- /dev/null +++ b/original/WG1/O-RAN.WG1.OAM-Architecture-v04.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:355d24fa8c105ad1950ba3f457db646e02028305f8ff05b8e716db2ec4cefa7e +size 3805951 diff --git a/original/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00.pdf b/original/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..57e61b7d899bc0cceb114cd34bc61a9c90e9b859 --- /dev/null +++ b/original/WG1/O-RAN.WG1.Study-on-O-RAN-Slicing-v02.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c5ba3f9b6b6714e1a11fe43331d5e2a79dc235fb56ef6c294d0139606cc8f206 +size 1292117 diff --git a/original/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00.docx b/original/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..9a246cf097f5a047c4a0159149f02bd503d5f2e1 --- /dev/null +++ b/original/WG1/O-RAN.WG1.TR.Decoupled-SMO-Architecture-R004-v03.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bdfaffe1d62d639bfd999a8793d5e50dce6822aa5e2cf62cf6e9753e1327d08c +size 1187035 diff --git a/original/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00.docx b/original/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..201354f8328c0e8d6050324968343459525b951f --- /dev/null +++ b/original/WG1/O-RAN.WG1.TR.SA-MVD-R004-v03.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b0285e65fad88e4311bf186247b757ef314884583cb6dd3f721298534a9c92b0 +size 1414799 diff --git a/original/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00.docx b/original/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..dd15a9e203c2c1f54609a711f05b17b9fff8ca2d --- /dev/null +++ b/original/WG1/O-RAN.WG1.TR.SMO-INT-R004-v04.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3af0d214ff8dd6ab599c1791098ea97af47c1e5d04f8ef6564f6b04596996fda +size 144608 diff --git a/original/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00.pdf b/original/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..e8a67c26313a3937d15a01c79016835cee6b83f2 --- /dev/null +++ b/original/WG1/O-RAN.WG1.TS.Slicing-Architecture-R004-v14.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cefaf25a5e01606cef1ad16bac934218fbadbcfa371b10033a011ae2acb24e48 +size 3745650 diff --git a/original/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00.pdf b/original/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..054caa8f39aa3a5b71980f02d756e832bf0aa1cb --- /dev/null +++ b/original/WG1/O-RAN.WG1.mMIMO-Use-Cases-TR-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:042ac1000d6031ab80758e62902e723e7c2c6f21d2e7b51954e2a44e6c19831e +size 3591144 diff --git a/original/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00.pdf b/original/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..88b6b1d8555ff31e28302fbc31bbcb7aa04bb333 --- /dev/null +++ b/original/WG10/O-RAN.WG10.TE&IV-UCR.0-R004-v03.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a062d4ce0974781a819be6bf347762fa3d1ee368c50ce2d492065e7bf0515da9 +size 1397212 diff --git a/original/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00.pdf b/original/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..0d5836b5b248bebc0c4b7fe1e209785b7cb188ee --- /dev/null +++ b/original/WG10/O-RAN.WG10.TS.O1NRM.0-R004-v02.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:accc7c58fa5070d2f7326ef9b0ed71a8e4bf80f97c9867a92bc88b59cdbc58cf +size 617421 diff --git a/original/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00.pdf b/original/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..276a186be236ec8a69cf1800c0976db8107412ff --- /dev/null +++ b/original/WG10/O-RAN.WG10.TS.OAM-Architecture-R004-v14.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:29ec376fc9fc4992f93107c9172873eed4236e4f022b944a46c2e40eaf39a0a2 +size 8582368 diff --git a/original/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00.docx b/original/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..cdbc70ea38431b7cdab8618c25f388cc94a59d2e --- /dev/null +++ b/original/WG10/O-RAN.WG10.TS.OnboardingSMOSGAP.0-R004-v01.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5609c8a40f0d12bf6c554a5fea49f0159c7d3560c6d55678474b71731773585d +size 118997 diff --git a/original/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00.docx b/original/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..132bf049e1c7228ac3276cabe196573c95a9f9b9 --- /dev/null +++ b/original/WG11/O-RAN.WG11.AppLCM-Security-TR.0-R003-v03.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3eda2f9bbaaee413926dfecbbbd294489f176ceff7f8ad3ae153c0ee3ce12eab +size 887674 diff --git a/original/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00.docx b/original/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..d0ede534840c4db730cf859dcb9a1b7b421f13f4 --- /dev/null +++ b/original/WG11/O-RAN.WG11.Certficate-Management-Framework-TR.0-R004-v04.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9f55f030a98ed4f88d7b96552d388cc8bb28b2c0c76445b0a45e87394793aa17 +size 1699349 diff --git a/original/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00.docx b/original/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..eeeda73ad4ed3647c442cef5b22852a06c8cccca --- /dev/null +++ b/original/WG11/O-RAN.WG11.O-CLOUD-Security-Analysis-TR.O-R004-v07.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a78561e0859782bc217b00b2356ec944c79ea782974857b4d628caeac95b8343 +size 2412326 diff --git a/original/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00.docx b/original/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..6ab4777974ef309217781550a9b3c46f1524c076 --- /dev/null +++ b/original/WG11/O-RAN.WG11.OAuth2.0-Security-TR.0-R004-v03.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5d3d4693a904bc47fa5268456ae19ca4b6b70d2102229dfd5ff2fd5b2ad33fe6 +size 434270 diff --git a/original/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00.docx b/original/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..86b4718245215d2d96da023e80efc3c99511c5be --- /dev/null +++ b/original/WG11/O-RAN.WG11.Security-Log-Management-TR.O-R004-v05.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b527e25202264851de2f2fb680fd27de35d695feda7ec6edd8bd5de3a6e11f72 +size 799425 diff --git a/original/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00.docx b/original/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..c92df2fda77f7f68c58f89229adb7e0157d4e538 --- /dev/null +++ b/original/WG11/O-RAN.WG11.Security-Near-RT-RIC-xApps-TR.0-R003-v05.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:6533556b7bd530b9ddd40b9d4fd9fc83768bfe46c08cb2380970fd621115b198 +size 949805 diff --git a/original/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00.docx b/original/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..73d2a98771972366db551e590f19869a23cc4cf9 --- /dev/null +++ b/original/WG11/O-RAN.WG11.TR.Fronthaul-CUSPlane-Security.0-R004-v03.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a52e8b1892429a6bca4d06d6b26e244bc184fdb1f2fe91de4358012909b9239e +size 8396599 diff --git a/original/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00.docx b/original/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..f9ddf12192694e7c348c295276cbcae4302d57db --- /dev/null +++ b/original/WG11/O-RAN.WG11.TR.O-RUCUM-R004-v04.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:0031175d6eed1efdc73886b5f49478e9e50401dbdefadc08092781e5092fb4b8 +size 212396 diff --git a/original/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00.docx b/original/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..e03aef2ebdc30e5f82677215db429741ff70aa2b --- /dev/null +++ b/original/WG11/O-RAN.WG11.TR.OAuth2.0-Security.O-R004-v04.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:67f5af4b48ae03d550dd72ae6461fb9dcc2a10ac3e87c9040d1ef562af0913aa +size 525236 diff --git a/original/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00.docx b/original/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..9eb40825a9b8710870c58728763c1f07d3bbf887 --- /dev/null +++ b/original/WG11/O-RAN.WG11.TR.Threat-Modeling.O-R004-v05.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2bad8afd31bdfb02b821007996a52de1e24108af5b7a47657950c5a6441c8c4a +size 1359310 diff --git a/original/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00.docx b/original/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..17588f197f2a6b5309952691db5aea6961a3204b --- /dev/null +++ b/original/WG11/O-RAN.WG11.TS.Security-Protocols-Specification.0-R004-v11.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f9b1398169c15cec27d92c5316cadada784ea03ea4a5536215b38bce89a839a0 +size 226802 diff --git a/original/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00.docx b/original/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..aa029768d9c3409dfd665501af4b59655caf2ba4 --- /dev/null +++ b/original/WG11/O-RAN.WG11.TS.Security-Requirements-Specification.0-R004-v11.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:04435d0c9a9d3e57bd7af4a0e35ebf0657636239227565c1cbb94af7d0721c44 +size 1149799 diff --git a/original/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00.docx b/original/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..fb60dbea95839c1afa020c9cae5c55ea38b1ac81 --- /dev/null +++ b/original/WG11/O-RAN.WG11.TS.Security-Test-Specifications-R004-v09.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:76c9177987feebc9a5305a8b3e9da54d5a69d2604d1615c2e425113b85777a9f +size 3544827 diff --git a/original/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00.docx b/original/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..7c01d79beca681a2c614e242899f16caeb83d855 --- /dev/null +++ b/original/WG11/ORAN-WG11-SharedORU-Security-Analysis-TR.0-R004-v06.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:7bece6f5f7b092cb31663c7d62d09e4e2ce574fe578f6a2fd6a70969b1f1dc32 +size 1224193 diff --git a/original/WG2/O-RAN.WG2.AIML-v01.03.pdf b/original/WG2/O-RAN.WG2.AIML-v01.03.pdf new file mode 100644 index 0000000000000000000000000000000000000000..9ceaa7e6ccda66a7ca2f8b4e29613c6b5fa5ca82 --- /dev/null +++ b/original/WG2/O-RAN.WG2.AIML-v01.03.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:afd260f0360d91e64516f637c17bdd25f24ec5594fe67429a48b5ffd69e4611c +size 3692403 diff --git a/original/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00.docx b/original/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..e47fa94560adb829de2cd48cc51da6a1a1aa51b8 --- /dev/null +++ b/original/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-R004-v06.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:37f5a26a106959e9ef264208d46972f08349132e39137e3e2fecf30d376bf71b +size 3789404 diff --git a/original/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01.pdf b/original/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01.pdf new file mode 100644 index 0000000000000000000000000000000000000000..5bcc3d309aed604e633f0131326eac561bb16c0c --- /dev/null +++ b/original/WG2/O-RAN.WG2.Non-RT-RIC-ARCH-TR-v01.01.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:366cb05674d3104148c4e2a83610bb441d6a38dfc97dadf76c0b23d8db915f8f +size 3902882 diff --git a/original/WG2/O-RAN.WG2.R1TP-v04.02.docx b/original/WG2/O-RAN.WG2.R1TP-v04.02.docx new file mode 100644 index 0000000000000000000000000000000000000000..ce242d8954e611692d1ca12c34b10624ed8e992a --- /dev/null +++ b/original/WG2/O-RAN.WG2.R1TP-v04.02.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:84f23dfb6f143926e416622ab7e3ac3e55bfc162bdc65b99af66da7246dbc2a4 +size 141321 diff --git a/original/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04.docx b/original/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04.docx new file mode 100644 index 0000000000000000000000000000000000000000..d0605a1a9fcfb2dc213ea66d0699338a1ede1491 --- /dev/null +++ b/original/WG2/O-RAN.WG2.TS.A1TP-R004-v03.04.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b40117b8c69c774f65694e0894690bedb6c1b23c334ad66c8c22b174418aa750 +size 112447 diff --git a/original/WG3/O-RAN.WG3.E2TS-R003-v02.00.docx b/original/WG3/O-RAN.WG3.E2TS-R003-v02.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..e10ce26d5d0744e90425c655ae458c640569cd48 --- /dev/null +++ b/original/WG3/O-RAN.WG3.E2TS-R003-v02.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:c7b25fb7d7f0269f03a75762c58d25316fb1384fb1e81f6f9b5dc274ddadf950 +size 449268 diff --git a/original/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00.docx b/original/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..aa1f73e72c9cc998472d586d4fa4d5308fac90d1 --- /dev/null +++ b/original/WG3/O-RAN.WG3.O1-Interface-for-Near-RT-RIC-R003-v01.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:a8d98799bcff1b923aea0d8a0fb3855f42ae4d0ae66181f8ba6afd9256bb7195 +size 118822 diff --git a/original/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00.docx b/original/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..4f7addf394fa56805f2a7eebcb4d9daaa44e3bea --- /dev/null +++ b/original/WG3/O-RAN.WG3.TR.ConMit-R004-v01.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:bade55c3789c24f108f393f3dbbef2341cb46e67e5327e93060f99a727588e94 +size 1207834 diff --git a/original/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00.pdf b/original/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..ff348a4ece42cee6089ccf21e10c9223a4cef0a4 --- /dev/null +++ b/original/WG3/O-RAN.WG3.TS.E2AP-R004-v07.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5393fd8ae38bd3999473669ef3aba8d010157f044476ed275efe956c90d4f2ac +size 3579727 diff --git a/original/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00.pdf b/original/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..8b9d91a77dbe635a9de88e309b54511c7b683790 --- /dev/null +++ b/original/WG3/O-RAN.WG3.TS.E2GAP-R004-v07.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9b28f7730c4f80d854bb2461d8df8d7f4716a24255281e845c366fc382b6b9e8 +size 1026720 diff --git a/original/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00.pdf b/original/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..b45942b8c0a00b52fbd194e06e8cc328c3348365 --- /dev/null +++ b/original/WG3/O-RAN.WG3.TS.E2SM-CCC-R004-v05.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:743bcbad23ecf20c7c6f2f31c1ede85b79688e6ff51eddf432b331a04852cc16 +size 1287711 diff --git a/original/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00.pdf b/original/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..3035d594358b89490288a3bdfa7fc6d499aa3c64 --- /dev/null +++ b/original/WG3/O-RAN.WG3.TS.E2SM-KPM-R004-v06.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:950b9296382cbcbbb6b93bc1c34429ea8a10526174bb2e6afef4cbbdb4ba1946 +size 1066846 diff --git a/original/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00.pdf b/original/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..ffe07e234d996beb9620b9fbf4b6aa72056cfeba --- /dev/null +++ b/original/WG3/O-RAN.WG3.TS.E2SM-LLC-R004-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b917d19e4dfbf6d5efca202012468f1b55b490937fb20b2f01f87a0953f37790 +size 768821 diff --git a/original/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00.pdf b/original/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..39fab3a447998c22ed24eec09e740da7b4dbe423 --- /dev/null +++ b/original/WG3/O-RAN.WG3.TS.E2SM-R004-v07.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:356eb9c84a4b11032051ad402659bc29c883b3a3267fec68b3559f6771de47e6 +size 1258694 diff --git a/original/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00.pdf b/original/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..37d5007256ed002b3d58ce31c6303d22e3e596ad --- /dev/null +++ b/original/WG3/O-RAN.WG3.TS.E2SM-RC-R004-v07.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ffd8b69f954152a3d92a0dfb6ed1d029b6cde0711a90ade4c885adf276d78adf +size 5351660 diff --git a/original/WG3/ORAN-WG3.E2SM-NI-v01.00.pdf b/original/WG3/ORAN-WG3.E2SM-NI-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..1c3fecbc7a1aba904cd59ab7fb3e6249f3122113 --- /dev/null +++ b/original/WG3/ORAN-WG3.E2SM-NI-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:1f5e1012fb2d434e2088c54f5ec04d9bfc3c783f8476db913b8dfd7053fc5dfe +size 771333 diff --git a/original/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00.pdf b/original/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..359d328f84393f4b9123387e15ccaeff2105977e --- /dev/null +++ b/original/WG4/O-RAN.WG4.CTI-TCP.0-R003-v04.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9c108c795dc448880b5905878ed4618b205017c9ca5b1e013733d25ad6415253 +size 3178470 diff --git a/original/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00.pdf b/original/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..9ce19d399108694357b04611d7f92ed856e4ef40 --- /dev/null +++ b/original/WG4/O-RAN.WG4.CTI-TMP.0-R003-v04.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:802f2868e5a515ec085542477e53c82b23538ec5567b3cf3b26cac39ed25f7ae +size 4087754 diff --git a/original/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00.pdf b/original/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..7e24201881e787387db3fb67e3ea41fbdee21b15 --- /dev/null +++ b/original/WG5/O-RAN.WG5.O-CU-O1.0-R003-v07.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b760bcdfb863171c1cd88dbe021a911328a9a9fd420ef06f6ac04be330ca787e +size 2039082 diff --git a/original/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00.pdf b/original/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..beb088ab1fa77d916787d661c8a71983e765982b --- /dev/null +++ b/original/WG5/O-RAN.WG5.O-DU-O1.0-R003-v09.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ab8fffc95cc878329133f5eea4a00520fe7b643327f33add5aae4fba62bd49ed +size 3031709 diff --git a/original/WG5/O-RAN.WG5.Transport.0-v01.00.docx b/original/WG5/O-RAN.WG5.Transport.0-v01.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..7d9a47361cddddc1bee8c44e6f46542417c8b649 --- /dev/null +++ b/original/WG5/O-RAN.WG5.Transport.0-v01.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9a87fa76d6536fe726eb1eb24ac0cc73c52d60708c33df1536e30628c16196c5 +size 330957 diff --git a/original/WG5/O-RAN.WG5.U.0-R003-v07.00.docx b/original/WG5/O-RAN.WG5.U.0-R003-v07.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..b0fa444be669a9a1173f28e5ccb53f8856c9615b --- /dev/null +++ b/original/WG5/O-RAN.WG5.U.0-R003-v07.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2211fac297e198afb1cfcb95e6392b42d9d88d61b22f1ea67bbf5ae0a626767a +size 170329 diff --git a/original/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00.pdf b/original/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..8f133b2f0c20c9a163225665eea14aa5ec76fec1 --- /dev/null +++ b/original/WG6/O-RAN-WG6.AppLCM-Deployment-R003-v02.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:dd74c19a3a8c9eea64500682af7a572da31fd5c51830bdcf5e356fee5665c7fe +size 1221555 diff --git a/original/WG6/O-RAN.WG6.AAL FEC.R004-v04.00.docx b/original/WG6/O-RAN.WG6.AAL FEC.R004-v04.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..a653ed525c1e1b97969a8d2096823715a1a4aaa9 --- /dev/null +++ b/original/WG6/O-RAN.WG6.AAL FEC.R004-v04.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ff7ab08dcfbb2bbfdd2f7b9fb3cb82da860f4f7c707e064ceb9f15c266ece98f +size 180835 diff --git a/original/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00.pdf b/original/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..5212633453cf7b59e2cca38d4fd7dcd16cd2eff1 --- /dev/null +++ b/original/WG6/O-RAN.WG6.AAL-Common-API-R003-v08.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:090330c278bf4400f2cff7743b25e7161f70a1c99f0d5b4a4d072b20d6f36048 +size 2264925 diff --git a/original/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00.docx b/original/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..4eed0672f39bee20580b341edb218779362034bf --- /dev/null +++ b/original/WG6/O-RAN.WG6.AAL-GAnP-R004-v10.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:f3b518bb23d8bddfa7303e66f5658da8e2c347f514a335c029e513c296a83c8f +size 2266346 diff --git a/original/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00.pdf b/original/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..1568b9f64e5eebf925a1e67615148f51ef7a9e78 --- /dev/null +++ b/original/WG6/O-RAN.WG6.AAL-GAnP-R004-v11.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e08ae35486f62d0b2dd74b87fd6e733bb48f0826755d1ebccb9be9743100bcf6 +size 1074092 diff --git a/original/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00.pdf b/original/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..abdb4d5bceb3e9adfd518f2347dfc6eecd02fd99 --- /dev/null +++ b/original/WG6/O-RAN.WG6.AAL-HI_PHY-R004-v07.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ced86ef8813d6d5e86848f561af1e13b98f5341e577d122b73b803b19c5804aa +size 907051 diff --git a/original/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01.pdf b/original/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01.pdf new file mode 100644 index 0000000000000000000000000000000000000000..cc5b194d21c177b1cf85f72624d0157ad37f24f9 --- /dev/null +++ b/original/WG6/O-RAN.WG6.AAL-MUMIMO-BF-Calc-Profile-R004-v01.01.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:54235c70ad3969df02226a7b632ba2f49e6b5658aba56209440c62789b45c62e +size 202931 diff --git a/original/WG6/O-RAN.WG6.ASD-R003-v01.00.docx b/original/WG6/O-RAN.WG6.ASD-R003-v01.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..3231325795ee63358a80c6cf579aafec11d51d3c --- /dev/null +++ b/original/WG6/O-RAN.WG6.ASD-R003-v01.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:09e9e9f0e75fd15924ec0acda441304cf47ac9da146a9fdcb30b69a85fd879cc +size 207368 diff --git a/original/WG6/O-RAN.WG6.CADS-v08.01.pdf b/original/WG6/O-RAN.WG6.CADS-v08.01.pdf new file mode 100644 index 0000000000000000000000000000000000000000..22b757ace70fa0f386b594a09d91453e188868be --- /dev/null +++ b/original/WG6/O-RAN.WG6.CADS-v08.01.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:e94cd5bf1cb98420bd9899c863c8875744f197f4ad9a0f728f4014170d47f57f +size 3065640 diff --git a/original/WG6/O-RAN.WG6.CLOUD-REF-v02.00.pdf b/original/WG6/O-RAN.WG6.CLOUD-REF-v02.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..a80fa9b925e179e9c4cd548f3fb0e9bd86482888 --- /dev/null +++ b/original/WG6/O-RAN.WG6.CLOUD-REF-v02.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2d866f86e5e3a5f66211995a7274475aa2b81f57c95b8e7851a32c79c3121826 +size 3009300 diff --git a/original/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00.docx b/original/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..de5149019144c683a047771c449cdd738cf5dac2 --- /dev/null +++ b/original/WG6/O-RAN.WG6.O-Cloud Notification API-v04.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ba8b2c0c78ca4ff646de1e0d54c3452bec6aabbd1bfba05ef4896e1bda70d6c7 +size 574336 diff --git a/original/WG6/O-RAN.WG6.O-Cloud-ES-v02.00.pdf b/original/WG6/O-RAN.WG6.O-Cloud-ES-v02.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..75295407372d43193e2d7c2b85a55d1e134844ae --- /dev/null +++ b/original/WG6/O-RAN.WG6.O-Cloud-ES-v02.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:be84efe2ede6ce12dcf3324f9ca5de810b53570aa237fb1a4c33209840e39a8a +size 2287448 diff --git a/original/WG6/O-RAN.WG6.O2-GAnP-v01.02.pdf b/original/WG6/O-RAN.WG6.O2-GAnP-v01.02.pdf new file mode 100644 index 0000000000000000000000000000000000000000..50b29203128379f11d70e3285d18786a2e7041dc --- /dev/null +++ b/original/WG6/O-RAN.WG6.O2-GAnP-v01.02.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:713f3370a2b05ec2b0ac7c665672095ef594596888e7c186b402fb0b0e4f480c +size 2961036 diff --git a/original/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00.docx b/original/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..5cc5896aeb034d6943572b7a88576ab8dc7e8494 Binary files /dev/null and b/original/WG6/O-RAN.WG6.O2-IMS-K8s-R003-v01.00.docx differ diff --git a/original/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00.pdf b/original/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..9a1f1ca9219bdeeec67dcad14d431cebb7d795ae --- /dev/null +++ b/original/WG6/O-RAN.WG6.TS.O-CLOUD-IM.0-R004-v03.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:56e85081f7282d916e822ac69feefbb96e25845be6102bae950dbb9a6b6ced23 +size 2195798 diff --git a/original/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01.pdf b/original/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01.pdf new file mode 100644 index 0000000000000000000000000000000000000000..5b667205cb30f65e7771b894d39b542eb695a065 --- /dev/null +++ b/original/WG6/O-RAN.WG6.TS.O-CLOUD-INTF-CONF-R004-v04.01.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:cf45238aed538d0f7d9bb3b35bbd1d7dfe05329fa7411a2669a4a724a621438b +size 923616 diff --git a/original/WG7/O-RAN.WG7.DSC.0-v04.00.pdf b/original/WG7/O-RAN.WG7.DSC.0-v04.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..7185d5aeb9d3cfbb5c54643cb39a9db2fdfcb379 --- /dev/null +++ b/original/WG7/O-RAN.WG7.DSC.0-v04.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:9fe1cd2120c05b3f9492733f8374f4d4a976f69c06870c5677ee462f30353e15 +size 556161 diff --git a/original/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00.pdf b/original/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..d6062c3ddc09344020f3de4bde609d957f2b8fa2 --- /dev/null +++ b/original/WG7/O-RAN.WG7.EMC-HAR-HRD.0-R003-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d9eeced166f401dbbefb757e1b87651e13c715261d681009c8a4d6ee0ae428e7 +size 1449563 diff --git a/original/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00.pdf b/original/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..6b1e2ab313842bdfc633330b5335352bf6fb04b0 --- /dev/null +++ b/original/WG7/O-RAN.WG7.FHGW-HRD.0-v02.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:76f4e742bf4d832ce1c9e1a832795742c93b91f967294c0bb21eea7565681688 +size 1185914 diff --git a/original/WG7/O-RAN.WG7.IPC-HAR.0-v03.00.pdf b/original/WG7/O-RAN.WG7.IPC-HAR.0-v03.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..4d8d3958b159a8a38770ba401cbd1f3b791e4c5d --- /dev/null +++ b/original/WG7/O-RAN.WG7.IPC-HAR.0-v03.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:841ea58c835dc1a20e3fda2598987a149d535f2a6fa3b094902a25d763370248 +size 2012433 diff --git a/original/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00.pdf b/original/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..503b33f8cd3345c9a3fd24c2588b4c82261c3b1e --- /dev/null +++ b/original/WG7/O-RAN.WG7.IPC-HRD-Opt6-v02.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:62c6c9f515c3764ffd7c905c598ee1873949bd6b02e4a8a286d10e478025bbb0 +size 1801251 diff --git a/original/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00.pdf b/original/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..617c53641a702044d009035ef871ef9995f18169 --- /dev/null +++ b/original/WG7/O-RAN.WG7.IPC-HRD-Opt7-2.0-v03.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:ec5482e51b98d940764ea8243de97f405fcb0f35f4d7d25801f8dd244763bb41 +size 5057290 diff --git a/original/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00.pdf b/original/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..e12f8dec3dc657107b3dd7f66f21a56595c0a638 --- /dev/null +++ b/original/WG7/O-RAN.WG7.IPC-HRD-Opt8.0-v03.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:081806fa7e36a58dc6bfed233e59c31414e1c16f8ac190a01bafd6ba7edfd114 +size 5104074 diff --git a/original/WG7/O-RAN.WG7.IPC-TEST.0-v01.docx b/original/WG7/O-RAN.WG7.IPC-TEST.0-v01.docx new file mode 100644 index 0000000000000000000000000000000000000000..5491ad2bcd8e1db9e16e6d7ab04a45f08d40505b --- /dev/null +++ b/original/WG7/O-RAN.WG7.IPC-TEST.0-v01.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:d25fb773649cf3b21dac84dfa51b9b7e63fcc0ab417f0032ab58fc3b802efbfc +size 593174 diff --git a/original/WG7/O-RAN.WG7.NES.0-R003-v02.00.pdf b/original/WG7/O-RAN.WG7.NES.0-R003-v02.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..24a65c59822b6118abb9fe8d903617337fcf6839 --- /dev/null +++ b/original/WG7/O-RAN.WG7.NES.0-R003-v02.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b42f07afcbced219d64d3c7a7496063a10d49d43cab41ec7e7e84aab235c1de7 +size 1269649 diff --git a/original/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00.pdf b/original/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..0be9369d71cfaf204585b7dddce2127138198554 --- /dev/null +++ b/original/WG7/O-RAN.WG7.OMAC-HAR.0-v05.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:78ffc4476839dd0ecda54f1c1c8bf29db073fda34d1f7b5419193219f40129b8 +size 1282045 diff --git a/original/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00.pdf b/original/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..b5688c8f03b756886d0260f5ca69c7a4a13a2171 --- /dev/null +++ b/original/WG7/O-RAN.WG7.OMAC-HRD.0-R003-v03.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:b37f100898bfb7f40f0bdebb987c81d9a9ddc42581d65ccff9d869ed83bceba4 +size 4060493 diff --git a/original/WG7/O-RAN.WG7.OMC-HAR.0-v01.00.pdf b/original/WG7/O-RAN.WG7.OMC-HAR.0-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..3754fe38ee7874b0a55e763038ded35806922a4b --- /dev/null +++ b/original/WG7/O-RAN.WG7.OMC-HAR.0-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:2e8e9c983e097db97fab48dbedc32db2f006ccddbad820b63fd41147f8935222 +size 807131 diff --git a/original/WG8/O-RAN.WG8.IOT.0-R004-v12.00.docx b/original/WG8/O-RAN.WG8.IOT.0-R004-v12.00.docx new file mode 100644 index 0000000000000000000000000000000000000000..aaa365387bf624a5d39e1df4873ee84aff002f7f --- /dev/null +++ b/original/WG8/O-RAN.WG8.IOT.0-R004-v12.00.docx @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:98b6a42a0cdf86b628555df316215875cde0870719f902f0e8a95ec5fdc2d56e +size 1328217 diff --git a/original/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00.pdf b/original/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..f7933b77a83af6171b911a4761d01a79e3791b7b --- /dev/null +++ b/original/WG9/O-RAN.WG9.XTRP-MGT.0-R004-v09.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5c62d41e7a6dc7c1e32e8a3956b52392855a7b1ffea58728ea61bf0cc373f33b +size 7873681 diff --git a/original/WG9/O-RAN.WG9.XTRP-REQ-v01.00.pdf b/original/WG9/O-RAN.WG9.XTRP-REQ-v01.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..3a6f44bfe2f82547101e52e5022305eff5868b2b --- /dev/null +++ b/original/WG9/O-RAN.WG9.XTRP-REQ-v01.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5fb7291d88b92c1f554fd720d7b28fa6e0458f2feae9eb6c2248ffdc441a648b +size 2637971 diff --git a/original/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00.pdf b/original/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..ef0d5ffa5b171f080b576d63286af9c2deb654b8 --- /dev/null +++ b/original/WG9/O-RAN.WG9.XTRP-SYN.0-R004-v06.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:3af9137f21dcdcc5cf9f0335265b1aa04aaad4669607bae3cd97c481b827607e +size 5655139 diff --git a/original/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00.pdf b/original/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..c606a56c6964d94af18bd22f3a794e5c017b7df5 --- /dev/null +++ b/original/WG9/O-RAN.WG9.XTRP-TST.0-R004-v05.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:5867d6330eadc4c90f94b922e710e7df951361b93c5217e8b38e5c2f76317c0d +size 13479727 diff --git a/original/WG9/ORAN-WG9.WDM.0-R004-v05.00.pdf b/original/WG9/ORAN-WG9.WDM.0-R004-v05.00.pdf new file mode 100644 index 0000000000000000000000000000000000000000..c39d2356eb8586f96edf72ffc7bfce6ff46b75b6 --- /dev/null +++ b/original/WG9/ORAN-WG9.WDM.0-R004-v05.00.pdf @@ -0,0 +1,3 @@ +version https://git-lfs.github.com/spec/v1 +oid sha256:61ea3061689f7a39cd281e6d2c9e987d4d6a9c937d9b9d4a9a575fe78361b2ef +size 2741553